WorldWideScience

Sample records for tracer bolus passages

  1. Evaluation of a bolus/infusion protocol for 11C-ABP688, a PET tracer for mGluR5

    International Nuclear Information System (INIS)

    Burger, Cyrill; Deschwanden, Alexandra; Ametamey, Simon; Johayem, Anass; Mancosu, Bruno; Wyss, Matthias; Hasler, Gregor; Buck, Alfred

    2010-01-01

    11 C-ABP-688 is a selective tracer for the mGluR5 receptor. Its kinetics is fast and thus favourable for an equilibrium approach to determine receptor-related parameters. The purpose of this study was to test the hypothesis that the pattern of the 11 C-ABP688 uptake using a bolus-plus-infusion (B/I) protocol at early time points corresponds to the perfusion and at a later time point to the total distribution volume. Methods: A bolus and a B/I study (1 h each) was performed in five healthy male volunteers. With the B/I protocol, early and late scans were normalized to gray matter, cerebellum and white matter. The same normalization was done on the maps of the total distribution volume (Vt) and K 1 which were calculated in the study with bolus only injection and the Logan method (Vt) and a two-tissue compartment model (K 1 ). Results: There was an excellent correlation close to the identity line between the pattern of the late uptake in the B/I study and Vt of the bolus-only study for all three normalizations. The pattern of the early uptake in the B/I study correlated well with the K 1 maps, but only when normalized to gray matter and cerebellum, not to white matter. Conclusion: It is demonstrated that with a B/I protocol the 11 C-ABP688 distribution in late scans reflects the pattern of the total distribution volume and is therefore a measure for the density pattern of mGluR5. The early scans following injection are related to blood flow, although not in a fully quantitative manner. The advantage of the B/I protocol is that no arterial blood sampling is required, which is advantageous in clinical studies.

  2. Nuclear heart function diagnostics. Studies during the first tracer passage and on the distribution equilibrium

    International Nuclear Information System (INIS)

    Feistel, H.

    1982-01-01

    The author attempted to establish a method of evaluation for gated blood pool scintiscanning. The necessary hardware for this purpose was installed, and a method of evaluation for the image sequences was developed on the basis of the medicine-specific GAMMA-11 routines. In addition, the inflow phase directly after the injection was observed. Two different images were possible, i.e. left-oblique in 45 0 projection or right-oblique in 30 0 projection. The findings were evaluated by an analysis of the cyclic heart action and by a quantitative determination of global parameters of the heart function, e.g. ejection fraction, rate of volume change etc. The regional myocardial motility can be assessed after orthogonal transformation into an amplitude image and a phase image. A new type of transformation is presented, i.e. the ''quantized sine/cosine transformation'' which allows fast calculation without a floating-point processor. States of akinesia and dyskinesia are well imaged. The first-passage technique gives a general picture of the cardiopulmonary situation. The algorithms described were used in 26 cardiac examinations of 24 patients. Ten further patients were examined by angiography. Except for one case of hypokinesia of the back wall, all disturbances of motility were detected. The angiographic and scintigraphic ejection fractions are correlated with r = 0.98, the rates between first-pass and gated study with r = 0.92, and the rates between 12-picture and 48-picture sequences with r = 0.98. (orig./MG) [de

  3. Gastrostomy feeding tube - bolus

    Science.gov (United States)

    Feeding - gastrostomy tube - bolus; G-tube - bolus; Gastrostomy button - bolus; Bard Button - bolus; MIC-KEY - bolus ... KEY, 3 to 8 weeks after surgery. These feedings will help your child grow strong and healthy. ...

  4. Bolus injections of measured amounts of radioactivity

    International Nuclear Information System (INIS)

    Wesolowski, C.A.; Hogendoorn, P.; Vandierendonck, R.; Driedger, A.A.

    1988-01-01

    Many time-based radionuclide techniques, such as glomerular filtration rate measurement (GFR), require prompt intravenous delivery of and accurately measured tracer bolus with minimal residual tracer retention at the injection site. The quality assurance aspects of two antecubital vein, quantitative injection techniques were investigated. A flush bolus technique using a tuberculin syringe piggybacked onto a 10-ml saline flush was compared to a single blood pressure cuff injection technique. Scintillation camera data for each technique were compared for bolus duration in the abdominal aorta and for residual activity at the injection site at 5 min. Bolus times were measured as the FWHM of the gamma variate fit to the abdominal aortic regional time-activity curves. Relatively little focal activity was seen in the antecubital injection site following the flush bolus: marked residual activity was seen following the blood pressure cuff injections. The injection site/arm background ratios averaged 1.3 for the flush bolus and 30.1 for the cuff technique. Although both methods allowed accurate in vitro determination of administered radioactivity, only the tuberculin syringe flush bolus technique was acceptable for time-based quantitation because of its superior in vivo characteristics

  5. Esophageal contractions, bolus transit and perception of transit after swallows of liquid and solid boluses in normal subjects

    Directory of Open Access Journals (Sweden)

    Juciléia Dalmazo

    2012-12-01

    Full Text Available CONTEXT: Esophageal dysphagia is the sensation that the ingested material has a slow transit or blockage in its normal passage to the stomach. It is not always associated with motility or transit alterations. OBJECTIVES: To evaluate in normal volunteers the possibility of perception of bolus transit through the esophagus after swallows of liquid and solid boluses, the differences in esophageal contraction and transit with these boluses, and the association of transit perception with alteration of esophageal contraction and/or transit. METHODS: The investigation included 11 asymptomatic volunteers, 4 men and 7 women aged 19-58 years. The subjects were evaluated in the sitting position. They performed swallows of the same volume of liquid (isotonic drink and solid (macaroni boluses in a random order and in duplicate. After each swallow they were asked about the sensation of bolus passage through the esophagus. Contractions and transit were evaluated simultaneously by solid state manometry and impedance. RESULTS: Perception of bolus transit occurred only with the solid bolus. The amplitude and area under the curve of contractions were higher with swallows of the solid bolus than with swallows of the liquid bolus. The difference was more evident in swallows with no perception of transit (n = 12 than in swallows with perception (n = 10. The total bolus transit time was longer for the solid bolus than for the liquid bolus only with swallows followed by no perception of transit. CONCLUSION: The results suggest that the perception of esophageal transit may be the consequence of inadequate adaptation of esophageal transit and contraction to the characteristics of the swallowed bolus.

  6. Bolus use in radiotherapy

    Directory of Open Access Journals (Sweden)

    Sérgio Spezzia

    2017-01-01

    Full Text Available Preliminary to the radiation therapy, it is posisble to develop a therapeutic device contained in the buccomaxillofacial prosthesis resources, creating the bolus. Bolus are materials used to increase the dose on the entrance surface of a field or to compensate for a lack of tissue. The requirements for a material to be used as a bolus include to interact with ionizing radiations in a similar manner to tissues and to be soft enough to allow its molding to the patient’s contour. There are various materials available for this purpose, however, with a relatively high cost. Some inexpensive options can also be used, such as pressed cellophane and wet gauze, however, these materials do not present favorable malleability and do not offer true reproducibility. The aim of this article was to ascertain whether there is harmonious knowledge of this technique by dental surgeons, medical oncologists and radiotherapists. This technique or device minimizes the deleterious effects resulting from exposure to radiation. It was concluded the bolus can reduce possible complications arising from radiation therapy, concomitantly offering improved living conditions during treatment.

  7. Association between swallow perception and esophageal bolus clearance in patients with globus sensation.

    Science.gov (United States)

    Chen, Chien-Lin; Yi, Chih-Hsun; Liu, Tso-Tsai

    2013-04-01

    Globus sensation is common, but its pathogenesis is not yet clear. Our purpose was to investigate subjective perception of swallowing and esophageal motility by combined multichannel intraluminal impedance and manometry (MII-EM) for patients with globus sensation. Combined MII-EM was performed for 25 globus patients and 15 healthy controls. Swallows were abnormal if hypocontractivity or simultaneous contractions occurred. Esophageal bolus transit was incomplete if bolus exit was not found at one or more of all measurement sites. Perception of each swallow was assessed by use of a standardized scoring system, and was enhanced if the score was >1. Few globus patients reported enhanced perception during viscous or solid swallows. Incomplete bolus transit and enhanced perception occurred similarly between viscous and solid boluses. Agreement between enhanced perception and proximal bolus clearance was greater during solid swallows (κ = 0.45, 95 % CI: 0.32-0.58) than during viscous swallows (κ = 0.13, 95 % CI: 0-0.25) (P perception and total bolus clearance was greater during solid swallows (κ = 0.46, 95 % CI: 0.34-0.58) than during viscous swallows (κ = 0.11, 95 % CI: 0-0.22) (P perception is uncommon in patients with globus sensation, although there is a significant association between enhanced esophageal perception and solid bolus clearance. Application of a solid bolus may help better delineation of the interrelationship between the subjective perception of bolus passage and the objective measurement of bolus clearance.

  8. Solid bolus swallowing in the radiologic evaluation of dysphagia

    International Nuclear Information System (INIS)

    Westen, D. van; Ekberg, O.

    1993-01-01

    Patients with dysphagia, heartburn and chest pain are regularly referred for radiologic evaluation of swallowing. The liquid barium swallow has been of great value for the biphasic evaluation of the pharynx and esophagus. Though many patients complain of dysphagia specifically for solids, solid bolus swallow is ususally not part of the evaluation. For the present study we therefore included the use of a solid bolus with a diameter of 13 mm and interviewed the patients carefully for any symptoms during this tablet swallow. Of 200 patients examined, the tablet passed through the esophagus without delay in 102. In the 98 patients with delayed passage, the solid bolus arrest occurred in the pharynx in 5 and in the esophagus in 93. Arrest in the esophagus was due to esophageal dysmotility in 48 patients. Twenty of these were symptomatic during the tablet swallow. A narrowing was the cause in 45, of whom 9 had symptoms. In 18 patients (9%) the solid bolus added key information to the radiologic evaluation. We therefore recommend that the solid bolus is included in the routine radiologic work-up of patients with dysphagia. Careful attention to symptoms during the tablet swallow is important. (orig.)

  9. Solid bolus swallowing in the radiologic evaluation of dysphagia

    Energy Technology Data Exchange (ETDEWEB)

    Westen, D. van (Dept. of Diagnostic Radiology, Malmoe General Hospital, Univ. Lund (Sweden)); Ekberg, O. (Dept. of Diagnostic Radiology, Malmoe General Hospital, Univ. Lund (Sweden))

    1993-07-01

    Patients with dysphagia, heartburn and chest pain are regularly referred for radiologic evaluation of swallowing. The liquid barium swallow has been of great value for the biphasic evaluation of the pharynx and esophagus. Though many patients complain of dysphagia specifically for solids, solid bolus swallow is ususally not part of the evaluation. For the present study we therefore included the use of a solid bolus with a diameter of 13 mm and interviewed the patients carefully for any symptoms during this tablet swallow. Of 200 patients examined, the tablet passed through the esophagus without delay in 102. In the 98 patients with delayed passage, the solid bolus arrest occurred in the pharynx in 5 and in the esophagus in 93. Arrest in the esophagus was due to esophageal dysmotility in 48 patients. Twenty of these were symptomatic during the tablet swallow. A narrowing was the cause in 45, of whom 9 had symptoms. In 18 patients (9%) the solid bolus added key information to the radiologic evaluation. We therefore recommend that the solid bolus is included in the routine radiologic work-up of patients with dysphagia. Careful attention to symptoms during the tablet swallow is important. (orig.).

  10. Bolus obstruction by Ascaris lumbricoides

    African Journals Online (AJOL)

    In 67 cases conservative treatment was successful. ... bolus of worms, biliary ascariasis,3.6 pancreatitis and acute ... or chronic granulomatous peritonitis is rare.i These complica- ... obstruction admitted to the paediatric surgical wards of the.

  11. Characterization of an intravenously injected bolus

    International Nuclear Information System (INIS)

    Samuel, A.M.; Raikar, U.R.; Atmaram, S.H.; Ganatra, R.D.

    1976-01-01

    A study of some parameters affecting the time activity histogram of an intravenous bolus injection of radioactivity was performed. A scoring system for bolus compactness was attempted. A score of 2 and above was considered to be a satisfactory bolus. Volumes less than 1 ml tended to result in a satisfactory bolus. The nature of radiopharmaceutical injected, different injecters and age of the patient did not affect the score. Thyrotoxic patients gave the best bolus score. (orig.) [de

  12. Tumoral tracers

    International Nuclear Information System (INIS)

    Camargo, E.E.

    1979-01-01

    Direct tumor tracers are subdivided in the following categories:metabolite tracers, antitumoral tracers, radioactive proteins and cations. Use of 67 Ga-citrate as a clinically important tumoral tracer is emphasized and gallium-67 whole-body scintigraphy is discussed in detail. (M.A.) [pt

  13. Bolus characteristics based on Magnetic Resonance Angiography

    Directory of Open Access Journals (Sweden)

    Bi Xiaoming

    2006-10-01

    Full Text Available Abstract Background A detailed contrast bolus propagation model is essential for optimizing bolus-chasing Computed Tomography Angiography (CTA. Bolus characteristics were studied using bolus-timing datasets from Magnetic Resonance Angiography (MRA for adaptive controller design and validation. Methods MRA bolus-timing datasets of the aorta in thirty patients were analyzed by a program developed with MATLAB. Bolus characteristics, such as peak position, dispersion and bolus velocity, were studied. The bolus profile was fit to a convolution function, which would serve as a mathematical model of bolus propagation in future controller design. Results The maximum speed of the bolus in the aorta ranged from 5–13 cm/s and the dwell time ranged from 7–13 seconds. Bolus characteristics were well described by the proposed propagation model, which included the exact functional relationships between the parameters and aortic location. Conclusion The convolution function describes bolus dynamics reasonably well and could be used to implement the adaptive controller design.

  14. Barium and meat. A comparison between pharyngeal swallow of fluid and solid boluses

    Energy Technology Data Exchange (ETDEWEB)

    Ekberg, O.; Liedberg, B.; Oewall, B.

    The influence of bolus consistency on pharyngeal swallow was radiologically studied in 24 individuals by comparing liquid barium and solid meat after chewing. Pharyngeal function was apparently performed synchronously and symmetrically on both boluses. No definite conclusion about the influence on epiglottic mobility, closure of the laryngeal vestibule and relaxation of the circopharyngeal muscle could be drawn from this study. There was no difference in the elevation of the pharynx and larynx. The transit time for a solid bolus was shorter compared with that of a fluid bous. The transit time for the apex of the bolus was shorter than for the tail. A more marked elevation of the pharynx and larynx was followed by a shorter transit time. The width of the pharyngo-esophageal segment was larger in the transverse than in the sagittal diameter during the passage of the bolus and larger on solid compared with fluid swallow. Our results reflect the ability of pharyngeal swallow to be executed with precision and with few alterations due to variable bolus consistency.

  15. Tracer theory

    International Nuclear Information System (INIS)

    Margrita, R.

    1988-09-01

    Tracers are used in many fields of science to investigate mass transfer. The scope of tracers applications in Service of Applications Radioisotopes (S.A.R.-France) is large and concerns natural and industrial systems such as Sciences of earth: hydrology - civil engineering - Sedimentology - environmental studies. Industrial field: chemical engineering - mechanical engineering. A general tracer methodology has been developed in our laboratories from these different applications fields and this paper shows these different points of view in using tracers; our wish is that the methods used in an experimental field can be employed in an another one

  16. Comparison of bolus versus fractionated oral applications of [13C]-linoleic acid in humans.

    Science.gov (United States)

    Demmelmair, H; Iser, B; Rauh-Pfeiffer, A; Koletzko, B

    1999-07-01

    The endogenous conversion of linoleic acid into long-chain polyunsaturated fatty acids is of potential importance for meeting substrate requirements, particularly in young infants. After application of [13C]-linoleic acid, we estimated its conversion to dihomo-gamma-linolenic and arachidonic acids from only two blood samples. Oral tracer doses were given to five healthy adults as a single bolus. In four subjects the tracer was given in nine equal portions over 3 days. Concentration and 13C content of fatty acids from serum phospholipids were analysed by gas chromatography combustion isotope ratio-mass spectrometry. Areas under the tracer-concentration curves were calculated, and fractional transfer and turnover rates estimated from compartmental models. The median fractional turnover of linoleic acid was 93.7% per day (interquartile range 25.3) in the bolus group and 80. 0% per day (6.3) in the fraction group (NS). Fractional conversion of linoleic to dihomo-gamma-linolenic acid was 1.5% (0.9) vs. 2.1% (0.7) (bolus vs. fraction, P /= 0.94, P < 0.05) with the ratio of areas under the curve. Using areas under the curve overestimates the conversion, because different residence times are not considered. Estimation of conversion intensity appears possible with only one blood sample obtained after tracer application.

  17. Environmental Tracers

    Directory of Open Access Journals (Sweden)

    Trevor Elliot

    2014-10-01

    Full Text Available Environmental tracers continue to provide an important tool for understanding the source, flow and mixing dynamics of water resource systems through their imprint on the system or their sensitivity to alteration within it. However, 60 years or so after the first isotopic tracer studies were applied to hydrology, the use of isotopes and other environmental tracers are still not routinely necessarily applied in hydrogeological and water resources investigations where appropriate. There is therefore a continuing need to promote their use for developing sustainable management policies for the protection of water resources and the aquatic environment. This Special Issue focuses on the robustness or fitness-for-purpose of the application and use of environmental tracers in addressing problems and opportunities scientifically, to promote their wider use and to address substantive issues of vulnerability, sustainability, and uncertainty in (groundwater resources systems and their management.

  18. Pharyngeal Pressure and Timing During Bolus Transit

    Science.gov (United States)

    Walczak, Chelsea C.; Jones, Corinne A.; McCulloch, Timothy M.

    2018-01-01

    Determining intrabolus pressure (IBP) at the upper esophageal sphincter (UES) and in the esophagus has given compelling evidence that IBP can be a predictor for swallowing dysfunction. Studies have looked most superiorly at the low hypopharynx region but there has been no inquiry into what IBP measures throughout the entire pharynx can tell us. We present a study to describe the pressures within and surrounding the moving bolus throughout the pharynx and into the UES. Simultaneous HRM and videofluoroscopy were performed in 10 healthy subjects swallowing ten 10 mL thin-liquid barium boluses. Three events surrounding bolus movement were tracked via videofluoroscopy, two additional events were found using manometric measures. As the bolus passes through the pharynx, low pressure is created at and below the head of the bolus. A modest pressure increase is seen as the bolus passes through the pharynx and finally, high pressure is observed at the bolus tail, followed by an even larger pressure generation of a clearance event. HRM allows for greater resolution in data collection in the pharynx and in this study, aided in identifying semi unique characteristics around the hypopharynx and the UES which are consistent with the complex anatomy of the regions and the transition of the UES from active closure to relaxed opening. In the future, additional studies designed to look at aged and diseased populations may lead to better understanding of disease etiology, and treatment options. PMID:27565155

  19. Quantum first passage problem

    International Nuclear Information System (INIS)

    Kumar, N.

    1984-07-01

    Quantum first passage problem (QUIPP) is formulated and solved in terms of a constrained Feynman path integral. The related paradox of blocking of unitary evolution by continuous observation on the system implicit in QUIPP is briefly discussed. (author)

  20. Anxiety can significantly explain bolus perception in the context of hypotensive esophageal motility: Results of a large multicenter study in asymptomatic individuals.

    Science.gov (United States)

    Cisternas, D; Scheerens, C; Omari, T; Monrroy, H; Hani, A; Leguizamo, A; Bilder, C; Ditaranto, A; Ruiz de León, A; Pérez de la Serna, J; Valdovinos, M A; Coello, R; Abrahao, L; Remes-Troche, J; Meixueiro, A; Zavala, M A; Marin, I; Serra, J

    2017-09-01

    Previous studies have not been able to correlate manometry findings with bolus perception. The aim of this study was to evaluate correlation of different variables, including traditional manometric variables (at diagnostic and extreme thresholds), esophageal shortening, bolus transit, automated impedance manometry (AIM) metrics and mood with bolus passage perception in a large cohort of asymptomatic individuals. High resolution manometry (HRM) was performed in healthy individuals from nine centers. Perception was evaluated using a 5-point Likert scale. Anxiety was evaluated using Hospitalized Anxiety and Depression scale (HAD). Subgroup analysis was also performed classifying studies into normal, hypotensive, vigorous, and obstructive patterns. One hundred fifteen studies were analyzed (69 using HRM and 46 using high resolution impedance manometry (HRIM); 3.5% swallows in 9.6% of volunteers were perceived. There was no correlation of any of the traditional HRM variables, esophageal shortening, AIM metrics nor bolus transit with perception scores. There was no HRM variable showing difference in perception when comparing normal vs extreme values (percentile 1 or 99). Anxiety but not depression was correlated with perception. Among hypotensive pattern, anxiety was a strong predictor of variance in perception (R 2 up to .70). Bolus perception is less common than abnormal motility among healthy individuals. Neither esophageal motor function nor bolus dynamics evaluated with several techniques seems to explain differences in bolus perception. Different mechanisms seem to be relevant in different manometric patterns. Anxiety is a significant predictor of bolus perception in the context of hypotensive motility. © 2017 John Wiley & Sons Ltd.

  1. Technology for bolus verification in proton therapy

    Science.gov (United States)

    Shipulin, K. N.; Mytsin, G. V.; Agapov, A. V.

    2015-01-01

    To ensure the conformal depth-dose distribution of a proton beam within a target volume, complex shaped range shifters (so-called boluses), which account for the heterogeneous structure of patient tissue and organs in the beam path, were calculated and manufactured. The precise manufacturing of proton compensators used for patient treatment is a vital step in quality assurance in proton therapy. In this work a software-hardware complex that verifies the quality and precision of bolus manufacturing at the Medico-Technical Complex (MTC) was developed. The boluses consisted of a positioning system with two photoelectric biosensors. We evaluated 20 boluses used in proton therapy of five patients. A total number of 2562 experimental points were measured, of which only two points had values that differed from the calculated value by more than 0.5 mm. The other data points displayed a deviation within ±0.5 mm from the calculated value. The technology for bolus verification developed in this work can be used for the high precision testing of geometrical parameters of proton compensators in radiotherapy.

  2. Boundaries, transitions and passages

    NARCIS (Netherlands)

    Koenderink, Jan; van Doorn, Andrea J.; Pinna, Baingio; Wagemans, Johan

    2016-01-01

    Many pictures are approximately piecewise uniform quilts. The patches meet in transitional areas that have a vague, ribbon-like geometry. These borders may occasionally get lost and sometimes pick up again, creating a 'passage' that partly blends adjacent patches. This type of structure is widely

  3. Tranexamic Acid in Bolus Alone Vs Bolus and Continuous Infusion in Hip Arthroscopy

    OpenAIRE

    Fatih Karaaslan; Roberto Seijas; Andrea Sallent; Oscar Ares; Wenceslao Espinosa; Pedro Alvarez; Ramón Cugat; Patricia Lopez

    2017-01-01

    AIM: the present study examines the effects of tranexamic acid (TXA) on reducing blood loss during hip arthroscopy, comparing two different methods of administration (bolus vs infusion). METHODS: a prospective study with 70 patients undergoing hip arthroscopy was carried out. The patients within the TXA infusion group (group A) received TXA an 2-g intravenous bolus 30 min before skin incision intravenously followed by 10 mg/kg/h infusion (continued during the entire surgery)...

  4. The Northwest Passage Dispute

    DEFF Research Database (Denmark)

    Burke, Danita Catherine

    2018-01-01

    This is an article written for the Oxford Research Group "Sustainable Security" series. It gives an overview of the dispute of the Northwest Passage and discusses factors which will contribute to the evolution of the dispute in the 21st century. This short contribution summarizes and adds to the ...... to the research recently published by the author through Palgrave Macmillan, Danita Catherine Burke, 2018, International Disputes and Cultural Ideas in the Canadian Arctic...

  5. Safe structural food bolus in elderly: the relevant parameters

    OpenAIRE

    Vandenberghe-Descamps, Mathilde; Septier, Chantal; Prot, Aurélie; Tournier, Carole; Hennequin, Martine; Vigneau, Evelyne; Feron, Gilles; Labouré, Hélène

    2017-01-01

    Mastication is essential to prepare food into a bolus ready to be swallowed safely, with no choking risk. Based on food bolus properties, a masticatory normative indicator was developed by Woda et al. (2010) to identify impaired masticatory function within good oral health population. The aim of the present study was to identify relevant parameters of bolus' structure to differentiate safe to unsafe bolus among elderly contrasting by their dental status.93 elderly, 58% with at least 7 posteri...

  6. The Influence of Laterality of Pharyngeal Bolus Passage on Dysphagia in Hemiplegic Stroke Patients

    Science.gov (United States)

    Kim, Min Seok; Lee, Seong Jae; Seo, Dong Hyuk; Hyun, Jung Keun; Kim, Jae Il

    2012-01-01

    Objective To investigate swallowing laterality in hemiplegic patients with stroke and recovery of dysphagia according to the laterality. Method The sample was comprised of 46 dysphagic patients with hemiplegia after their first stroke. The sample's videofluoroscopic swallowing study (VFSS) was reviewed. Swallowing laterality was determined by the anterior-posterior view of VFSS. We measured width difference of barium sulfate liquid flow in the pharyngoesophageal segment. If there was double or more the width of that from the opposite width in the pharyngoesophageal segment more than twice on three trials of swallowing, then it was judged as having laterality. Subjects were assigned to no laterality (NL), laterality that is ipsilateral to hemiplegic side (LI), and laterality that is contralateral to hemiplegic side (LC) groups. We measured the following: prevalence of aspiration, the 8-point penetration-aspiration scale, and the functional dysphagia scale of the subjects at baseline and follow up. Results Laterality was observed in 45.7% of all patients. Among them, 52.4% were in the hemiplegic direction. There was no significant difference between groups at baseline in all measurements. When we compared the changes in all measurements on follow-up study, there were no significant differences between groups. Conclusion Through this study, we found that there was no significant relation between swallowing laterality and the severity or prognosis of swallowing difficulty. More studies for swallowing laterality on stroke patients will be needed. PMID:23185735

  7. Alternatives and passages

    DEFF Research Database (Denmark)

    Hansbøl, Mikala

    2010-01-01

    While much research into serious games focus on following teaching and/or learning activities, and particularly the human and institutional actors involved in these, the central actors of game based learning research (i.e. the games) seldom get much attention (unless the focus is so......-called "technological"). This brief positioning paper takes point of departure in an ongoing postdoc project following circulations and establishments of http://www.mingoville.com/ , which is a virtual universe with game based elements developed for beginning English teaching and learning.  The paper presents a Science...... and Technology Studies (STS) and Actor-Network-Theory (ANT) inspired approach to researching emerging passages between beginning English teaching and learning and Mingoville....

  8. A study on developing customized bolus using 3D prints

    International Nuclear Information System (INIS)

    Jung, Sang Min; Yang, Jin Ho; Lee, Seung Hyun; Kim, Jin Uk; Yeom, Du Seok

    2015-01-01

    3D Printers are used to create three-dimensional models based on blueprints. Based on this characteristic, it is feasible to develop a bolus that can minimize the air gap between skin and bolus in radiotherapy. This study aims to compare and analyze air gap and target dose at the branded 1 cm bolus with the developed customized bolus using 3D printers. RANDO phantom with a protruded tumor was used to procure images using CT simulator. CT DICOM file was transferred into the STL file, equivalent to 3D printers. Using this, customized bolus molding box (maintaining the 1 cm width) was created by processing 3D printers, and paraffin was melted to develop the customized bolus. The air gap of customized bolus and the branded 1 cm bolus was checked, and the differences in air gap was used to compare D max , D min , D mean , D 95% and V 95% in treatment plan through Eclipse. Customized bolus production period took about 3 days. The total volume of air gap was average 3.9 cm 3 at the customized bolus. And it was average 29.6cm 3 at the branded 1 cm bolus. The customized bolus developed by the 3D printer was more useful in minimizing the air gap than the branded 1 cm bolus. In the 6 MV photon, at the customized bolus, D max , D min , D mean , D 95% , V 95% of GTV were 102.8%, 88.1%, 99.1%, 95.0%, 94.4% and the D max , D min , D mean , D 95% , V 95% of branded 1 cm bolus were 101.4%, 92.0%, 98.2%, 95.2%, 95.7%, respectively. In the proton, at the customized bolus, D max , D min , D mean , D 95% , V 95% of GTV were 104.1%, 84.0%, 101.2%, 95.1%, 99.8% and the D max , D min , D mean , D 95% , V 95% of branded 1cm bolus were 104.8%, 87.9%, 101.5%, 94.9%, 99.9%, respectively. Thus, in treatment plan, there was no significant difference between the customized bolus and 1 cm bolus. However, the normal tissue nearby the GTV showed relatively lower radiation dose. The customized bolus developed by 3D printers was effective in minimizing the air gap, especially when it is used against

  9. A study on developing customized bolus using 3D prints

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Sang Min; Yang, Jin Ho; Lee, Seung Hyun; Kim, Jin Uk; Yeom, Du Seok [Dept. of Proton Therapy Center, National Cancer Center, Ilsan (Korea, Republic of)

    2015-06-15

    3D Printers are used to create three-dimensional models based on blueprints. Based on this characteristic, it is feasible to develop a bolus that can minimize the air gap between skin and bolus in radiotherapy. This study aims to compare and analyze air gap and target dose at the branded 1 cm bolus with the developed customized bolus using 3D printers. RANDO phantom with a protruded tumor was used to procure images using CT simulator. CT DICOM file was transferred into the STL file, equivalent to 3D printers. Using this, customized bolus molding box (maintaining the 1 cm width) was created by processing 3D printers, and paraffin was melted to develop the customized bolus. The air gap of customized bolus and the branded 1 cm bolus was checked, and the differences in air gap was used to compare D{sub max}, D{sub min}, D{sub mean}, D{sub 95%} and V{sub 95%} in treatment plan through Eclipse. Customized bolus production period took about 3 days. The total volume of air gap was average 3.9 cm{sup 3} at the customized bolus. And it was average 29.6cm{sup 3} at the branded 1 cm bolus. The customized bolus developed by the 3D printer was more useful in minimizing the air gap than the branded 1 cm bolus. In the 6 MV photon, at the customized bolus, D{sub max}, D{sub min}, D{sub mean}, D{sub 95%}, V{sub 95%} of GTV were 102.8%, 88.1%, 99.1%, 95.0%, 94.4% and the D{sub max}, D{sub min}, D{sub mean}, D{sub 95%}, V{sub 95%} of branded 1 cm bolus were 101.4%, 92.0%, 98.2%, 95.2%, 95.7%, respectively. In the proton, at the customized bolus, D{sub max}, D{sub min}, D{sub mean}, D{sub 95%}, V{sub 95%} of GTV were 104.1%, 84.0%, 101.2%, 95.1%, 99.8% and the D{sub max}, D{sub min}, D{sub mean}, D{sub 95%}, V{sub 95%} of branded 1cm bolus were 104.8%, 87.9%, 101.5%, 94.9%, 99.9%, respectively. Thus, in treatment plan, there was no significant difference between the customized bolus and 1 cm bolus. However, the normal tissue nearby the GTV showed relatively lower radiation dose. The

  10. Optical tracking of contrast medium bolus to optimize bolus shape and timing in dynamic computed tomography

    International Nuclear Information System (INIS)

    Eisa, Fabian; Brauweiler, Robert; Peetz, Alexander; Hupfer, Martin; Nowak, Tristan; Kalender, Willi A

    2012-01-01

    One of the biggest challenges in dynamic contrast-enhanced CT is the optimal synchronization of scan start and duration with contrast medium administration in order to optimize image contrast and to reduce the amount of contrast medium. We present a new optically based approach, which was developed to investigate and optimize bolus timing and shape. The time-concentration curve of an intravenously injected test bolus of a dye is measured in peripheral vessels with an optical sensor prior to the diagnostic CT scan. The curves can be used to assess bolus shapes as a function of injection protocols and to determine contrast medium arrival times. Preliminary results for phantom and animal experiments showed the expected linear behavior between dye concentration and absorption. The kinetics of the dye was compared to iodinated contrast medium and was found to be in good agreement. The contrast enhancement curves were reliably detected in three mice with individual bolus shapes and delay times of 2.1, 3.5 and 6.1 s, respectively. The optical sensor appears to be a promising approach to optimize injection protocols and contrast enhancement timing and is applicable to all modalities without implying any additional radiation dose. Clinical tests are still necessary. (note)

  11. Safety and efficacy of Bolus administration of magnesium sulphate ...

    African Journals Online (AJOL)

    Safety and efficacy of Bolus administration of magnesium sulphate for preeclampsia. ... On-going research is addressing its administration in terms of dosage, duration and safety. Objective: We evaluated a ... Keywords: safety, efficacy, bolus magnesium sulphate, preeclampsia, University of Benin Teaching Hospital

  12. Bolus obstruction by Ascaris lumbricoides | Wynne | South African ...

    African Journals Online (AJOL)

    Bolus obstruction by Ascaris lumbricoides. J.M. Wynne, B.A.H. Ellman. Abstract. Seventy-three cases of obstruction due to a bolus of Ascaris worms are reviewed, The diagnosis was made on the basis either of a characteristic palpable mass or a characteristic radiographic appearance. In 67 cases conservative treatment ...

  13. Analysis of tracer transit in rat brain after carotid artery and femoral vein administrations using linear system theory.

    Science.gov (United States)

    Rudin, M; Beckmann, N; Sauter, A

    1997-01-01

    Determination of tissue perfusion rates by MRI bolus tracking methods relies on the central volume principle which states that tissue blood flow is given by the tissue blood volume divided by the mean tracer transit time (MTT). Accurate determination of the MTT requires knowledge of the arterial input function which in MRI experiments is usually not known, especially when using small animals. The problem of unknown arterial input can be circumvented in animal experiments by directly injecting the contrast agent into a feeding artery of the tissue of interest. In the present article the passage of magnetite nanoparticles through the rat cerebral cortex is analyzed after injection into the internal carotid artery. The results are discussed in the framework of linear system theory using a one-compartment model for brain tissue and by using the well characterized gamma-variate function to describe the tissue concentration profile of the contrast agent. The results obtained from the intra-arterial tracer administration experiments are then compared with the commonly used intra-venous injection of the contrast agent in order to estimate the contribution of the peripheral circulation to the MTT values in the latter case. The experiments were analyzed using a two-compartment model and the gamma-variate function. As an application perfusion rates in normal and ischemic cerebral cortex of hypertensive rats were estimated in a model of focal cerebral ischemia. The results indicate that peripheral circulation has a significant influence on the MTT values and thus on the perfusion rates, which cannot be neglected.

  14. Packet Tracer network simulator

    CERN Document Server

    Jesin, A

    2014-01-01

    A practical, fast-paced guide that gives you all the information you need to successfully create networks and simulate them using Packet Tracer.Packet Tracer Network Simulator is aimed at students, instructors, and network administrators who wish to use this simulator to learn how to perform networking instead of investing in expensive, specialized hardware. This book assumes that you have a good amount of Cisco networking knowledge, and it will focus more on Packet Tracer rather than networking.

  15. Toxicity of fluorescent tracers and their degradation byproducts

    Directory of Open Access Journals (Sweden)

    Philippe Gombert

    2017-01-01

    Full Text Available Tracer tests are frequently used to delineate catchment area of water supply springs in karstic zones. In the karstic chalk of Normandy, the main tracers used are fluorescent: uranine, sulforhodamine B, naphtionate, and Tinopal®. In this area, a statistical analysis shows that less than half of the injected tracers joins the monitored restitution points and enters the drinking water system where they undergo chlorination. Most of the injected tracers is absorbed in the rock matrix or is thrown out of the aquifer via karstic springs: then it can join superficial waters where it is degraded due to the sun and air action. The paper presents firstly the laboratory degradation of a first batch of fluorescent tracers in contact with chlorine, in order to simulate their passage through a water treatment system for human consumption. A second batch of the same tracers is subjected to agents of natural degradation: ultraviolet illumination, sunlight and air sparging. Most tracers is degraded, and toxicity and ecotoxicity tests (on rats, daphniae and algae are performed on degradation byproducts. These tests do not show any acute toxicity but a low to moderate ecotoxicity. In conclusion, the most used fluorescent tracers of the Normandy karstic chalk and their artificial and natural degradation byproducts do not exhibit significant toxicity to humans and the aquatic environment, at the concentrations generally noted at the restitution points.

  16. Micropropagation of Gerbera (Gerbera jamesonii Bolus).

    Science.gov (United States)

    Minerva, Ghani; Kumar, Surinder

    2013-01-01

    Gerbera (Gerbera jamesonii Bolus) is one of the most popular ornamental flowers worldwide and used both as cut flower and potted plant. Some of them show excellent agronomic characters such as color, floral diameter, stem length, and vigor, which make this plant of commercial importance. Conventionally, multiplication is done through seeds or rhizome cuttings. Rapid multiplication of elite cultivars of Gerbera, with improved agronomic traits, has been achieved by using both direct and indirect tissue culture methods. Direct shoot regeneration was accomplished from stem apices on MS medium supplemented with 1 mg/L 6-benzyladenine (BA) and 1 mg/L kinetin. Indirect shoot induction succeeded from callus differentiation has been achieved on MS medium containing 2 mg/L 2,4-dichlorophenoxyacetic acid, 0.5 mg/L indole-3-acetic acid, and 2 mg/L BA. The in vitro shoots, 4-5 cm long, were rooted by quick dipping the shoot bases for 3-5 s in 2,000 mg/L indole-3-butyric acid solution followed by transfer to the pots containing farmyard manure, soil, and sand (1:1:1 by volume). Initially, in vitro plantlets were covered with glass jars to maintain a high relative humidity (85-90%). As soon as new shoot growth begins, relative humidity is decreased by exposing them to the open environmental conditions prior transferring to the glasshouse. Indirect shoot regeneration increased the frequency of somaclonal variations. The selected somaclones were used in developing new and novel cultivars.

  17. Contrast bolus technique with rapid CT scanning

    International Nuclear Information System (INIS)

    Arnold, H.; Kuehne, D.; Rohr, W.; Heller, M.

    1981-01-01

    Twenty-three patients complying with the clinical criteria for brain death were studied by contrast-enhanced CT. In all but one, the great intracranial vessels escaped visualization; accordingly, angiography demonstrated cerebral circulatory arrest. In the remaining case, faint enhancement of the circle of Willis corresponded to angiographic demonstration of the proximal segments of cerebral arteris. Neither in normal brain nor in dead brain did slow CT scanning disclose any postcontrast increase in parenchymal attenuation. An improved technique is proposed to demonstrate the transit of the contrast bolus by rapid CT with image splitting. If cerebral blood flow is preserved, the grey and white matter will enhance significantly following administration of contrast medium. Vice versa, the absence of enhancement confirms brain death, even in instances in which the great cerebral vessels are obscured by hemorrhage or other extensive lesions. Two additional cases of brain death were evaluated by rapid CT scanning. As to brain death, the technique obviates the need for angiography or radionuclide angiography, usually applied in prospective organ donors, because its informative content is superior to that of either method. The CT technique described affords a reliable and safe diagnosis of brain death, and can be interpreted easily. (orig.)

  18. Tracer gas diffusion sampling test plan

    International Nuclear Information System (INIS)

    Rohay, V.J.

    1993-01-01

    Efforts are under way to employ active and passive vapor extraction to remove carbon tetrachloride from the soil in the 200 West Area an the Hanford Site as part of the 200 West Area Carbon Tetrachloride Expedited Response Action. In the active approach, a vacuum is applied to a well, which causes soil gas surrounding the well to be drawn up to the surface. The contaminated air is cleaned by passage through a granular activated carbon bed. There are questions concerning the radius of influence associated with application of the vacuum system and related uncertainties about the soil-gas diffusion rates with and without the vacuum system present. To address these questions, a series of tracer gas diffusion sampling tests is proposed in which an inert, nontoxic tracer gas, sulfur hexafluoride (SF 6 ), will be injected into a well, and the rates of SF 6 diffusion through the surrounding soil horizon will be measured by sampling in nearby wells. Tracer gas tests will be conducted at sites very near the active vacuum extraction system and also at sites beyond the radius of influence of the active vacuum system. In the passive vapor extraction approach, barometric pressure fluctuations cause soil gas to be drawn to the surface through the well. At the passive sites, the effects of barometric ''pumping'' due to changes in atmospheric pressure will be investigated. Application of tracer gas testing to both the active and passive vapor extraction methods is described in the wellfield enhancement work plan (Rohay and Cameron 1993)

  19. Ocular Dynamics of Bolus Ingestion of Eleis guineensis Sap (Palm ...

    African Journals Online (AJOL)

    Elaeis guineensis), and is widely consumed among the various ethnic nationalities in Nigeria. The effect of bolus ingestion of 600ml, palm wine was undertaken so as to determine its ocular dynamics in healthy volunteers. Results showed that ...

  20. On bolus for megavoltage photon and electron radiation therapy

    International Nuclear Information System (INIS)

    Vyas, Vedang; Palmer, Lisa; Mudge, Ray; Jiang, Runqing; Fleck, Andre; Schaly, Bryan; Osei, Ernest; Charland, Paule

    2013-01-01

    Frequently, in radiation therapy one must treat superficial lesions on cancer patients; these are at or adjacent to the skin. Megavoltage photon radiotherapy penetrates through the skin to irradiate deep-seated tumors, with skin-sparing property. Hence, to treat superficial lesions, one must use a layer of scattering material to feign as the skin surface. Although megavoltage electron beams are used for superficial treatments, one occasionally needs to enhance the dose near the surface. Such is the function of a “bolus,” a natural or synthetically developed material that acts as a layer of tissue to provide a more effective treatment to the superficial lesions. Other uses of boluses are to correct for varying surface contours and to add scattering material around the patient's surface. Materials used as bolus vary from simple water to metal and include various mixtures and compounds. Even with the modernization of the technology for external-beam therapy and the emergence of various commercial boluses, the preparation and utilization of a bolus in clinical radiotherapy remains an art. Considering the varying experiences and practices, this paper briefly summarizes available boluses that have been proposed and are employed in clinical radiotherapy. Although this review is not exhaustive, it provides some initial guidance and answers questions that may arise in clinical practice

  1. Methods of bolusing the tracheostomy stoma

    International Nuclear Information System (INIS)

    Beitler, Jonathan J.; Yaparpalvi, Ravindra; Biancia, Cesar Della; Fontenla, Doracy P.

    2001-01-01

    Purpose: The tracheostomy stoma is a potential site of recurrence for patients who have subglottic cancer or subglottic spread of cancer. In these patients, it is important that the anterior supraclavicular field does not underdose the posterior wall of the tracheostomy stoma when using a 6-MV anterior photon field. Conventionally, this problem is surmounted with placement of a plastic tracheostomy tube, which is uncomfortable for the patient, potentially traumatic, and can interfere with vocalization via a tracheal esophageal puncture. Our study was designed to investigate the dosimetry of this region and see if alternate methods would be effective. Methods and Materials: A phantom was constructed using a No. 6 tracheostomy tube as the model for the tracheostomy curvature and size. Using the water-equivalent phantom, film dosimetry, and films oriented parallel to the en face field, we investigated the dose at the depth of the surface of the posterior wall of the phantom's tracheostomy stoma. Dose was measured both in space and at the tissue interface by scanning points of interest both horizontally and vertically. We measured doses with a No. 6 and No. 8 plastic tracheostomy tube, either 0.5 cm and 1.0 cm of bolus (1-cm airhole) with no tracheostomy tube, as well as 0.3 cm and 0.6 cm tissue-equivalent Aquaplast (Med-Tec Co., Orange City, Iowa) over the tracheostomy. Dosimetry at the posterior interface was confirmed using thermoluminescent dosimeters. Results: Three mm and 6 mm of Aquaplast produced a posterior tracheal dose of 93% and 100%. Conclusion: There is no need for these patients to wear a temporary plastic tracheostomy tube during their external radiation therapy. Aquaplast should allow better position reproducibility, reduce trauma, not interfere with patient respiratory efforts, and be compatible with vocalization via a tracheal esophageal puncture

  2. Practice Change From Intermittent Medication Boluses to Bolusing From a Continuous Infusion in Pediatric Critical Care: A Quality Improvement Project.

    Science.gov (United States)

    Hochstetler, Jessica L; Thompson, A Jill; Ball, Natalie M; Evans, Melissa C; Frame, Shaun C; Haney, A Lauren; Little, Amelia K; O'Donnell, Jaime L; Rickett, Bryna M; Mack, Elizabeth H

    2018-04-12

    To determine whether implementing a guideline to bolus medications from continuous infusions in PICUs affects nursing satisfaction, patient safety, central line entries, medication utilization, or cost. This is a pre- and postimplementation quality improvement study. An 11-bed ICU and 14-bed cardiac ICU in a university-affiliated children's hospital. Patients less than 18 years old admitted to the PICU or pediatric cardiac ICU receiving a continuous infusion of dexmedetomidine, midazolam, fentanyl, morphine, vecuronium, or cisatracurium from May 2015 to May 2016, excluding November 2015 (washout period), were eligible for inclusion. Change in practice from administering bolus doses from an automated dispensing machine to administering bolus medications from continuous infusion in PICUs. Timing studies were conducted pre- and post implementation in 29 and 26 occurrences, respectively. The median time from the decision to give a bolus until it began infusing decreased by 169 seconds (p 0.05). Annualized cost avoidance was $124,160. Implementation of bolus medications from continuous infusion in PICUs significantly decreased time to begin a bolus dose and increased nursing satisfaction. The practice change also improved medication utilization without negatively impacting patient safety.

  3. Tracer attenuation in groundwater

    Science.gov (United States)

    Cvetkovic, Vladimir

    2011-12-01

    The self-purifying capacity of aquifers strongly depends on the attenuation of waterborne contaminants, i.e., irreversible loss of contaminant mass on a given scale as a result of coupled transport and transformation processes. A general formulation of tracer attenuation in groundwater is presented. Basic sensitivities of attenuation to macrodispersion and retention are illustrated for a few typical retention mechanisms. Tracer recovery is suggested as an experimental proxy for attenuation. Unique experimental data of tracer recovery in crystalline rock compare favorably with the theoretical model that is based on diffusion-controlled retention. Non-Fickian hydrodynamic transport has potentially a large impact on field-scale attenuation of dissolved contaminants.

  4. Isotopic marking and tracers

    International Nuclear Information System (INIS)

    Morel, F.

    1997-01-01

    The use of radioactive isotopes as tracers in biology has been developed thanks to the economic generation of the required isotopes in accelerators and nuclear reactors, and to the multiple applications of tracers in the life domain; the most usual isotopes employed in biology are carbon, hydrogen, phosphorus and sulfur isotopes, because these elements are present in most of organic molecules. Most of the life science knowledge appears to be dependent to the extensive use of nuclear tools and radioactive tracers; the example of the utilization of radioactive phosphorus marked ATP to study the multiple reactions with proteins, nucleic acids, etc., is given

  5. Suitability of tracers

    International Nuclear Information System (INIS)

    Klotz, D.

    1999-01-01

    Hydrological tracer techniques are a means of making statements on the direction and speed of underground water. One of the simpler tasks is to find out whether there is hydrological communication between two given points. This requires a determination of the direction of flow, which places less exacting demands on the properties of the tracer than does the task of determining the flow velocity of underground water. Tracer methods can serve to infer from flow velocity the distance (flow) velocity, which is defined as the ratio between the distance between two points located in flow direction and the actual time it takes water to flow from one to the other [de

  6. Fabrication of malleable three-dimensional-printed customized bolus using three-dimensional scanner.

    Directory of Open Access Journals (Sweden)

    Jae Won Park

    Full Text Available A three-dimensional (3D-printed customized bolus (3D bolus can be used for radiotherapy application to irregular surfaces. However, bolus fabrication based on computed tomography (CT scans is complicated and also delivers unwanted irradiation. Consequently, we fabricated a bolus using a 3D scanner and evaluated its efficacy. The head of an Alderson Rando phantom was scanned with a 3D scanner. The 3D surface data were exported and reconstructed with Geomagic Design X software. A 3D bolus of 5-mm thickness designed to fit onto the nose was printed with the use of rubber-like printing material, and a radiotherapy plan was developed. We successfully fabricated the customized 3D bolus, and further, a CT simulation indicated an acceptable fit of the 3D bolus to the nose. There was no air gap between the bolus and the phantom surface. The percent depth dose (PDD curve of the phantom with the 3D bolus showed an enhanced surface dose when compared with that of the phantom without the bolus. The PDD of the 3D bolus was comparable with that of a commercial superflab bolus. The radiotherapy plan considering the 3D bolus showed improved target coverage when compared with that without the bolus. Thus, we successfully fabricated a customized 3D bolus for an irregular surface using a 3D scanner instead of a CT scanner.

  7. Tracers Detect Aquifer Contamination

    National Research Council Canada - National Science Library

    Enfield, Carl

    1995-01-01

    The EPA's National Laboratory (NRMRL) at Ada, OK, along with the University of Florida and the University of Texas, have developed a tracer procedure to detect the amount of contamination in aquifer formations...

  8. Radio-isotopic tracers

    International Nuclear Information System (INIS)

    Wolfangel, R.G.

    1976-01-01

    The invention concerns the dispersions that may be used for preparing radio-isotopic tracers, technetium labelled dispersions, processes for preparing these dispersions and their use as tracers. Technetium 99m sulphur colloids are utilized as scintillation tracers to give a picture of the reticulo-endothelial system, particularly the liver and spleen. A dispersion is provided which only requires the addition of a radioactive nuclide to form a radioactively labelled dispersion that can be injected as a tracer. It is formed of a colloid of tin sulphur dispersed in an aqueous buffer solution. Such a reagent has the advantage of being safe and reliable and is easier to use. The colloid can be prepared more quickly since additions of several different reagents are avoided. There is no need to heat up and no sulphuretted hydrogen, which is a toxic gas, is used [fr

  9. Tracer techniques in microelectronics

    International Nuclear Information System (INIS)

    Flachowsky, J.; Freyer, K.

    1981-01-01

    Tracer technique and neutron activation analysis are capable of measuring impurities in semiconductor material or on the semiconductor surface in a very low concentration range. The methods, combined with autoradiography, are also suitable to determine dopant distributions in silicon. However, both techniques suffer from certain inherent experimental difficulties and/or limitations which are discussed. Methods of tracer technique practicable in the semiconductor field are described. (author)

  10. Tracers and tracing methods

    International Nuclear Information System (INIS)

    Leclerc, J.P.

    2001-01-01

    The first international congress on 'Tracers and tracing methods' took place in Nancy in May 2001. The objective of this second congress was to present the current status and trends on tracing methods and their applications. It has given the opportunity to people from different fields to exchange scientific information and knowledge about tracer methodologies and applications. The target participants were the researchers, engineers and technologists of various industrial and research sectors: chemical engineering, environment, food engineering, bio-engineering, geology, hydrology, civil engineering, iron and steel production... Two sessions have been planned to cover both fundamental and industrial aspects: 1)fundamental development (tomography, tracer camera visualization and particles tracking; validation of computational fluid dynamics simulations by tracer experiments and numerical residence time distribution; new tracers and detectors or improvement and development of existing tracing methods; data treatments and modeling; reactive tracer experiments and interpretation) 2)industrial applications (geology, hydrogeology and oil field applications; civil engineering, mineral engineering and metallurgy applications; chemical engineering; environment; food engineering and bio-engineering). The program included 5 plenary lectures, 23 oral communications and around 50 posters. Only 9 presentations are interested for the INIS database

  11. Intravenous contrast medium administration at 128 multidetector row CT pulmonary angiography: Bolus tracking versus test bolus and the implications for diagnostic quality and effective dose

    International Nuclear Information System (INIS)

    Rodrigues, J.C.L.; Mathias, H.; Negus, I.S.; Manghat, N.E.; Hamilton, M.C.K.

    2012-01-01

    Aim: To investigate the effects of a test bolus protocol contrast medium administration on diagnostic image quality in computed tomography pulmonary angiography (CTPA). Materials and methods: Fifty patients referred for exclusion of pulmonary embolism underwent CTPA using a test bolus protocol CTPA at 120 kVp and were compared with 50 patients undergoing CTPA using a standard bolus-tracking protocol at 120 kVp, via assessment of attenuation, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) seen in the pulmonary arteries (PAs). An additional group of 10 non-obese patients who underwent CTPA using a test bolus protocol performed at 100 kVp were also analysed. Mean effective dose was calculated from the dose–length product, using standard conversion factors. Results: The test bolus protocol showed significantly higher attenuation, SNR, and CNR in the pulmonary vasculature down to the segmental level compared to bolus-tracking CTPA (p < 0.0001). There was no significant difference in effective dose between the test bolus and bolus tracking cohorts. The additional group of test bolus CTPA examinations performed at 100 kVp had a significantly reduced effective dose in comparison to both test bolus CTPA at 120 kVp and bolus-tracking CTPA at 120 kVp (p < 0.005) yet maintained mean PA attenuation to segmental level significantly better than bolus-tracking CTPA performed at 120 kVp and comparable to the test bolus cohort performed at 120 kVp. Conclusion: Test bolus contrast administration should be used as an optimal protocol. Performing test bolus CTPA at 100 kVp, as opposed to 120 kVp, significantly reduces dose without compromising PA attenuation in non-obese subjects.

  12. Esophageal Transit, Contraction and Perception of Transit After Swallows of Two Viscous Boluses.

    Science.gov (United States)

    Dalmazo, Jucileia; Aprile, Lilian Rose Otoboni; Dantas, Roberto Oliveira

    2015-10-01

    There have been results showing the influence of bolus viscosities and consistency on esophageal motility and transit. However, there is no description about the influence of two different viscous boluses on esophageal contractions, bolus transit and perception of transit. Our objective in this investigation was to evaluate the esophageal transit and contraction after swallows of two viscous boluses. By impedance and manometric methods, we measured the esophageal transit and contraction after swallows of two viscous boluses of 5 mL volume, 100% barium sulfate and yogurt, swallowed in duplicate in the supine and upright positions. The bolus transit, esophageal contractions and the perception of bolus transit through the esophagus were evaluated in both positions. Impedance and contraction were measured at 5, 10, 15 and 20 cm from the lower esophageal sphincter. After each swallow, the volunteers were asked about the sensation of bolus transit through the esophagus. In supine position, the yogurt had a less frequent complete bolus transit than barium. Also in the supine position, the esophageal transit was longer with yogurt than with barium. Esophageal contractions after swallows were similar between barium and yogurt boluses. There was no difference in perception of transit between the two boluses. Although both 100% barium sulfate and yogurt are viscous boluses and have similar viscosities, the transit through the esophagus is slower with yogurt bolus than with barium bolus, which suggests that viscosity may be not the sole factor to determine transit.

  13. A customized bolus produced using a 3-dimensional printer for radiotherapy.

    Science.gov (United States)

    Kim, Shin-Wook; Shin, Hun-Joo; Kay, Chul Seung; Son, Seok Hyun

    2014-01-01

    Boluses are used in high-energy radiotherapy in order to overcome the skin sparing effect. In practice though, commonly used flat boluses fail to make a perfect contact with the irregular surface of the patient's skin, resulting in air gaps. Hence, we fabricated a customized bolus using a 3-dimensional (3D) printer and evaluated its feasibility for radiotherapy. We designed two kinds of bolus for production on a 3D printer, one of which was the 3D printed flat bolus for the Blue water phantom and the other was a 3D printed customized bolus for the RANDO phantom. The 3D printed flat bolus was fabricated to verify its physical quality. The resulting 3D printed flat bolus was evaluated by assessing dosimetric parameters such as D1.5 cm, D5 cm, and D10 cm. The 3D printed customized bolus was then fabricated, and its quality and clinical feasibility were evaluated by visual inspection and by assessing dosimetric parameters such as Dmax, Dmin, Dmean, D90%, and V90%. The dosimetric parameters of the resulting 3D printed flat bolus showed that it was a useful dose escalating material, equivalent to a commercially available flat bolus. Analysis of the dosimetric parameters of the 3D printed customized bolus demonstrated that it is provided good dose escalation and good contact with the irregular surface of the RANDO phantom. A customized bolus produced using a 3D printer could potentially replace commercially available flat boluses.

  14. Stable isotope labeled n-alkanes to assess digesta passage kinetics through the digestive tract of ruminants

    NARCIS (Netherlands)

    Warner, D.; Ferreira, L.M.M.; Breuer, M.J.H.; Dijkstra, J.; Pellikaan, W.F.

    2013-01-01

    We describe the use of carbon stable isotope (13C) labeled n-alkanes as a potential internal tracer to assess passage kinetics of ingested nutrients in ruminants. Plant cuticular n-alkanes originating from intrinsically 13C labeled ryegrass plants were pulse dosed intraruminally in four

  15. Wairakei tracer tests 1983

    International Nuclear Information System (INIS)

    McCabe, W.J.; Barry, B.J.

    1984-05-01

    Tracer tests, with and without, hot water reinjection into WK213 showed returns of tracer iodine-131; in wells in both the Waiora Valley and the eastern end of the field. The effect of reinjection at a rate of 200 cu. m/h was to reduce the arrived time from 15 to 7 days. Increasing the rate of reinjection into WK62 from 30 cu. m/h to 200 cu. m/h seemed to increase the initial velocity of the tracer wave and the distance it moved. However, returns were recorded only in the adjacent wells WK61 and WK63 with a very small, and three days delayed, response in WK43

  16. Impaired bolus transit across the esophagogastric junction in postfundoplication dysphagia

    NARCIS (Netherlands)

    Scheffer, R. C. H.; Samsom, M.; Haverkamp, A.; Oors, J.; Hebbard, G. S.; Gooszen, H. G.

    2005-01-01

    This study assessed the effect of fundoplication on liquid and solid bolus transit across the esophagogastric junction (EGJ) in relation to EGJ dynamics and dysphagia. Twelve patients with gastro-esophageal reflux disease (GERD) were studied before and after fundoplication. Concurrent

  17. Dextrose boluses versus burette dextrose infusions in prevention of ...

    African Journals Online (AJOL)

    The incidence of hypoglycemia in the bolus arm was 59% (40/68) compared to 11% (8/72) in the ... and safety monitoring board (DSMB) was set up to oversee to ..... On the other hand, Namukwaya et al in a prospective study at Mulago ...

  18. Regional cerebral blood flow measurement with intravenous [15O]water bolus and [18F]fluoromethane inhalation

    International Nuclear Information System (INIS)

    Herholz, K.; Pietrzyk, U.; Wienhard, K.; Hebold, I.; Pawlik, G.; Wagner, R.; Holthoff, V.; Klinkhammer, P.; Heiss, W.D.

    1989-01-01

    In 20 patients with ischemic cerebrovascular disease, classic migraine, or angiomas, we compared paired dynamic positron emission tomographic measurements of regional cerebral blood flow using both [ 15 O]water and [ 18 F]fluoromethane as tracers. Cerebral blood flow was also determined according to the autoradiographic technique with a bolus injection of [ 15 O]water. There were reasonable overall correlations between dynamic [ 15 O]water and [ 18 F]fluoromethane values for cerebral blood flow (r = 0.82) and between dynamic and autoradiographic [ 15 O]water values for cerebral blood flow (r = 0.83). We found a close correspondence between abnormal pathologic findings and visually evaluated cerebral blood flow tomograms obtained with the two tracers. On average, dynamic [ 15 O]water cerebral blood flow was 6% lower than that measured with [ 18 F]fluoromethane. There also was a general trend toward a greater underestimation with [ 15 O]water in high-flow areas, particularly in hyperemic areas, probably due to incomplete first-pass extraction of [ 15 O]water. Underestimation was not detected in low-flow areas or in the cerebellum. Absolute cerebral blood flow values were less closely correlated between tracers and techniques than cerebral blood flow patterns. The variability of the relation between absolute flow values was probably caused by confounding effects of the variation in the circulatory delay time. The autoradiographic technique was most sensitive to this type error

  19. Comparison and evaluation between 3D-bolus and step-bolus, the assistive radiotherapy devices for the patients who had undergone modified radical mastectomy surgery

    Energy Technology Data Exchange (ETDEWEB)

    Jang, Won Seok; Park, Kwang Woo; Shin, Dong Bong; Kim, Jong Dae; Kim, Sei Joon; Ha, Jin Sook; Jeon, Mi Jin; Cho, Yoojin; Jung, Inho [Dept. of Radiation Oncology, Gangnam Severance Hospital, Seoul, (Korea, Republic of)

    2016-06-15

    This study aimed to compare and evaluate between the efficiency of two respective devices, 3D-bolus and step-bolus when the devices were used for the treatment of patients whose chest walls were required to undergo the electron beam therapy after the surgical procedure of modified radical mastectomy, MRM. The treatment plan of reverse hockey stick method, using the photon beam and electron beam, had been set for six breast cancer patients and these 6 breast cancer patients were selected to be the subjects for this study. The prescribed dose of electron beam for anterior chest wall was set to be 180 cGy per treatment and both the 3D-bolus, produced using 3D printer(CubeX, 3D systems, USA) and the self-made conventional step-bolus were used respectively. The surface dose under 3D-bolus and step-bolus was measured at 5 measurement spots of iso-center, lateral, medial, superior and inferior point, using GAFCHROMIC EBT3 film (International specialty products, USA) and the measured value of dose at 5 spots was compared and analyzed. Also the respective treatment plan was devised, considering the adoption of 3D-bolus and stepbolus and the separate treatment results were compared to each other. The average surface dose was 179.17 cGy when the device of 3D-bolus was adopted and 172.02 cGy when step-bolus was adopted. The average error rate against the prescribed dose of 180 cGy was -(minus) 0.47% when the device of 3D-bolus was adopted and it was -(minus) 4.43% when step-bolus was adopted. It was turned out that the maximum error rate at the point of iso-center was 2.69%, in case of 3D-bolus adoption and it was 5,54% in case of step-bolus adoption. The maximum discrepancy in terms of treatment accuracy was revealed to be about 6% when step-bolus was adopted and to be about 3% when 3D-bolus was adopted. The difference in average target dose on chest wall between 3D-bolus treatment plan and step-bolus treatment plan was shown to be insignificant as the difference was only 0

  20. Comparison and evaluation between 3D-bolus and step-bolus, the assistive radiotherapy devices for the patients who had undergone modified radical mastectomy surgery

    International Nuclear Information System (INIS)

    Jang, Won Seok; Park, Kwang Woo; Shin, Dong Bong; Kim, Jong Dae; Kim, Sei Joon; Ha, Jin Sook; Jeon, Mi Jin; Cho, Yoojin; Jung, Inho

    2016-01-01

    This study aimed to compare and evaluate between the efficiency of two respective devices, 3D-bolus and step-bolus when the devices were used for the treatment of patients whose chest walls were required to undergo the electron beam therapy after the surgical procedure of modified radical mastectomy, MRM. The treatment plan of reverse hockey stick method, using the photon beam and electron beam, had been set for six breast cancer patients and these 6 breast cancer patients were selected to be the subjects for this study. The prescribed dose of electron beam for anterior chest wall was set to be 180 cGy per treatment and both the 3D-bolus, produced using 3D printer(CubeX, 3D systems, USA) and the self-made conventional step-bolus were used respectively. The surface dose under 3D-bolus and step-bolus was measured at 5 measurement spots of iso-center, lateral, medial, superior and inferior point, using GAFCHROMIC EBT3 film (International specialty products, USA) and the measured value of dose at 5 spots was compared and analyzed. Also the respective treatment plan was devised, considering the adoption of 3D-bolus and stepbolus and the separate treatment results were compared to each other. The average surface dose was 179.17 cGy when the device of 3D-bolus was adopted and 172.02 cGy when step-bolus was adopted. The average error rate against the prescribed dose of 180 cGy was -(minus) 0.47% when the device of 3D-bolus was adopted and it was -(minus) 4.43% when step-bolus was adopted. It was turned out that the maximum error rate at the point of iso-center was 2.69%, in case of 3D-bolus adoption and it was 5,54% in case of step-bolus adoption. The maximum discrepancy in terms of treatment accuracy was revealed to be about 6% when step-bolus was adopted and to be about 3% when 3D-bolus was adopted. The difference in average target dose on chest wall between 3D-bolus treatment plan and step-bolus treatment plan was shown to be insignificant as the difference was only 0

  1. SU-C-213-03: Custom 3D Printed Boluses for Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, B; Yang, M; Yan, Y; Rahimi, A; Chopra, R; Jiang, S [UT Southwestern Medical Center, Dallas, TX (United States)

    2015-06-15

    Purpose: To develop a clinical workflow and to commission the process of creating custom 3d printed boluses for radiation therapy. Methods: We designed a workflow to create custom boluses using a commercial 3D printer. Contours of several patients were deformably mapped to phantoms where the test bolus contours were designed. Treatment plans were created on the phantoms following our institutional planning guideline. The DICOM file of the bolus contours were then converted to stereoLithography (stl) file for the 3d printer. The boluses were printed on a commercial 3D printer using polylactic acid (PLA) material. Custom printing parameters were optimized in order to meet the requirement of bolus composition. The workflow was tested on multiple anatomical sites such as skull, nose and chest wall. The size of boluses varies from 6×9cm2 to 12×25cm2. To commission the process, basic CT and dose properties of the printing materials were measured in photon and electron beams and compared against water and soft superflab bolus. Phantoms were then scanned to confirm the placement of custom boluses. Finally dose distributions with rescanned CTs were compared with those computer-generated boluses. Results: The relative electron density(1.08±0.006) of the printed boluses resemble those of liquid tap water(1.04±0.004). The dosimetric properties resemble those of liquid tap water(1.04±0.004). The dosimetric properties were measured at dmax with an ion chamber in electron and photon open beams. Compared with solid water and soft bolus, the output difference was within 1% for the 3D printer material. The printed boluses fit well to the phantom surfaces on CT scans. The dose distribution and DVH based on the printed boluses match well with those based on TPS generated boluses. Conclusion: 3d printing provides a cost effective and convenient solution for patient-specific boluses in radiation therapy.

  2. SU-C-213-03: Custom 3D Printed Boluses for Radiation Therapy

    International Nuclear Information System (INIS)

    Zhao, B; Yang, M; Yan, Y; Rahimi, A; Chopra, R; Jiang, S

    2015-01-01

    Purpose: To develop a clinical workflow and to commission the process of creating custom 3d printed boluses for radiation therapy. Methods: We designed a workflow to create custom boluses using a commercial 3D printer. Contours of several patients were deformably mapped to phantoms where the test bolus contours were designed. Treatment plans were created on the phantoms following our institutional planning guideline. The DICOM file of the bolus contours were then converted to stereoLithography (stl) file for the 3d printer. The boluses were printed on a commercial 3D printer using polylactic acid (PLA) material. Custom printing parameters were optimized in order to meet the requirement of bolus composition. The workflow was tested on multiple anatomical sites such as skull, nose and chest wall. The size of boluses varies from 6×9cm2 to 12×25cm2. To commission the process, basic CT and dose properties of the printing materials were measured in photon and electron beams and compared against water and soft superflab bolus. Phantoms were then scanned to confirm the placement of custom boluses. Finally dose distributions with rescanned CTs were compared with those computer-generated boluses. Results: The relative electron density(1.08±0.006) of the printed boluses resemble those of liquid tap water(1.04±0.004). The dosimetric properties resemble those of liquid tap water(1.04±0.004). The dosimetric properties were measured at dmax with an ion chamber in electron and photon open beams. Compared with solid water and soft bolus, the output difference was within 1% for the 3D printer material. The printed boluses fit well to the phantom surfaces on CT scans. The dose distribution and DVH based on the printed boluses match well with those based on TPS generated boluses. Conclusion: 3d printing provides a cost effective and convenient solution for patient-specific boluses in radiation therapy

  3. SU-C-213-06: Dosimetric Verification of 3D Printed Electron Bolus

    International Nuclear Information System (INIS)

    Rasmussen, K; Corbett, M; Pelletier, C; Huang, Z; Feng, Y; Jung, J

    2015-01-01

    Purpose: To determine the dosimetric effect of 3D printed bolus in an anthropomorphic phantom. Methods: Conformable bolus material was generated for an anthropomorphic phantom from a DICOM volume. The bolus generated was a uniform expansion of 5mm applied to the nose region of the phantom, as this is a difficult area to uniformly apply bolus clinically. A Printrbot metal 3D Printer using PLA plastic generated the bolus. A 9MeV anterior beam with a 5cm cone was used to deliver dose to the nose of the phantom. TLD measurements were compared to predicted values at the phantom surface. Film planes were analyzed for the printed bolus, a standard 5mm bolus sheet placed on the phantom, and the phantom with no bolus applied to determine depth and dose distributions. Results: TLDs measured within 2.5% of predicted value for the 3D bolus. Film demonstrated a more uniform dose distribution in the nostril region for the 3d printed bolus than the standard bolus. This difference is caused by the air gap created around the nostrils by the standard bolus, creating a secondary build-up region. Both demonstrated a 50% central axis dose shift of 5mm relative to the no bolus film. HU for the bolus calculated the PLA electron density to be ∼1.1g/cc. Physical density was measured to be 1.3g/cc overall. Conclusion: 3D printed PLA bolus demonstrates improved dosimetric performance to standard bolus for electron beams with complex phantom geometry

  4. The influence of a solid and liquid bolus on food-stimulated gastroesophageal reflux

    International Nuclear Information System (INIS)

    Naeser, A.; Behrens, J.K.; Vejen-Christiansen, L.; Funch-Jensen, P.; Thommesen, P.; Aarhus Kommunehospital

    1992-01-01

    Using a radiological method to demonstrate food-stimulated gastroesophageal reflux (GER), a comparative study was carried out employing a solid, already validated bolus versus a liquid one. One hundred and four consecutive patients received both a solid and a liquid bolus in randomized order. GER was observed in 37 (35.6%) patients receiving the solid bolus versus 28 (26.9%) with the liquid one. This means that the solid bolus provokes significantly more reflux (P [de

  5. SU-C-213-06: Dosimetric Verification of 3D Printed Electron Bolus

    Energy Technology Data Exchange (ETDEWEB)

    Rasmussen, K; Corbett, M; Pelletier, C; Huang, Z; Feng, Y; Jung, J [East Carolina Univ, Greenville, NC (United States)

    2015-06-15

    Purpose: To determine the dosimetric effect of 3D printed bolus in an anthropomorphic phantom. Methods: Conformable bolus material was generated for an anthropomorphic phantom from a DICOM volume. The bolus generated was a uniform expansion of 5mm applied to the nose region of the phantom, as this is a difficult area to uniformly apply bolus clinically. A Printrbot metal 3D Printer using PLA plastic generated the bolus. A 9MeV anterior beam with a 5cm cone was used to deliver dose to the nose of the phantom. TLD measurements were compared to predicted values at the phantom surface. Film planes were analyzed for the printed bolus, a standard 5mm bolus sheet placed on the phantom, and the phantom with no bolus applied to determine depth and dose distributions. Results: TLDs measured within 2.5% of predicted value for the 3D bolus. Film demonstrated a more uniform dose distribution in the nostril region for the 3d printed bolus than the standard bolus. This difference is caused by the air gap created around the nostrils by the standard bolus, creating a secondary build-up region. Both demonstrated a 50% central axis dose shift of 5mm relative to the no bolus film. HU for the bolus calculated the PLA electron density to be ∼1.1g/cc. Physical density was measured to be 1.3g/cc overall. Conclusion: 3D printed PLA bolus demonstrates improved dosimetric performance to standard bolus for electron beams with complex phantom geometry.

  6. Models for tracer flow

    International Nuclear Information System (INIS)

    Zuber, A.

    1983-01-01

    A review and discussion is given of mathematical models used for interpretation of tracer experiments in hydrology. For dispersion model, different initial and boundary conditions are related to different injection and detection modes. Examples of applications of various models are described and commented. (author)

  7. 21 CFR 520.1660c - Oxytetracycline hydrochloride tablets/boluses.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Oxytetracycline hydrochloride tablets/boluses. 520....1660c Oxytetracycline hydrochloride tablets/boluses. (a) Specifications. Each tablet or bolus contains 250, 500, or 1,000 milligrams of oxytetracycline hydrochloride. (b) Sponsors. For sponsors in § 510...

  8. Xanthine tracers and their preparation

    International Nuclear Information System (INIS)

    Groman, E.V.; Cabelli, M.D.

    1980-01-01

    Compounds useful as tracers in the radioimmunoassay of xanthine derivatives such as theophylline and pharmacologically related drugs are described. They are substituted xanthines in which at least one substituted radical contains radioiodine. The tracers are made by linking radioiodinatable or preradioiodinated radicals to the xanthine derivative which is to be assayed. The tracers may be employed in known radioimmunoassay techniques. (author)

  9. Role of physical bolus properties as sensory inputs in the trigger of swallowing.

    Science.gov (United States)

    Peyron, Marie-Agnès; Gierczynski, Isabelle; Hartmann, Christoph; Loret, Chrystel; Dardevet, Dominique; Martin, Nathalie; Woda, Alain

    2011-01-01

    Swallowing is triggered when a food bolus being prepared by mastication has reached a defined state. However, although this view is consensual and well supported, the physical properties of the swallowable bolus have been under-researched. We tested the hypothesis that measuring bolus physical changes during the masticatory sequence to deglutition would reveal the bolus properties potentially involved in swallowing initiation. Twenty normo-dentate young adults were instructed to chew portions of cereal and spit out the boluses at different times in the masticatory sequence. The mechanical properties of the collected boluses were measured by a texture profile analysis test currently used in food science. The median particle size of the boluses was evaluated by sieving. In a simultaneous sensory study, twenty-five other subjects expressed their perception of bolus texture dominating at any mastication time. Several physical changes appeared in the food bolus as it was formed during mastication: (1) in rheological terms, bolus hardness rapidly decreased as the masticatory sequence progressed, (2) by contrast, adhesiveness, springiness and cohesiveness regularly increased until the time of swallowing, (3) median particle size, indicating the bolus particle size distribution, decreased mostly during the first third of the masticatory sequence, (4) except for hardness, the rheological changes still appeared in the boluses collected just before swallowing, and (5) physical changes occurred, with sensory stickiness being described by the subjects as a dominant perception of the bolus at the end of mastication. Although these physical and sensory changes progressed in the course of mastication, those observed just before swallowing seem to be involved in swallowing initiation. They can be considered as strong candidates for sensory inputs from the bolus that are probably crucially involved in the triggering of swallowing, since they appeared in boluses prepared in various

  10. Role of physical bolus properties as sensory inputs in the trigger of swallowing.

    Directory of Open Access Journals (Sweden)

    Marie-Agnès Peyron

    Full Text Available BACKGROUND: Swallowing is triggered when a food bolus being prepared by mastication has reached a defined state. However, although this view is consensual and well supported, the physical properties of the swallowable bolus have been under-researched. We tested the hypothesis that measuring bolus physical changes during the masticatory sequence to deglutition would reveal the bolus properties potentially involved in swallowing initiation. METHODS: Twenty normo-dentate young adults were instructed to chew portions of cereal and spit out the boluses at different times in the masticatory sequence. The mechanical properties of the collected boluses were measured by a texture profile analysis test currently used in food science. The median particle size of the boluses was evaluated by sieving. In a simultaneous sensory study, twenty-five other subjects expressed their perception of bolus texture dominating at any mastication time. FINDINGS: Several physical changes appeared in the food bolus as it was formed during mastication: (1 in rheological terms, bolus hardness rapidly decreased as the masticatory sequence progressed, (2 by contrast, adhesiveness, springiness and cohesiveness regularly increased until the time of swallowing, (3 median particle size, indicating the bolus particle size distribution, decreased mostly during the first third of the masticatory sequence, (4 except for hardness, the rheological changes still appeared in the boluses collected just before swallowing, and (5 physical changes occurred, with sensory stickiness being described by the subjects as a dominant perception of the bolus at the end of mastication. CONCLUSIONS: Although these physical and sensory changes progressed in the course of mastication, those observed just before swallowing seem to be involved in swallowing initiation. They can be considered as strong candidates for sensory inputs from the bolus that are probably crucially involved in the triggering of

  11. First passage time in a two-layer system

    International Nuclear Information System (INIS)

    Lee, J.; Koplik, J.

    1995-01-01

    As a first step in the first passage problem for passive tracer in stratified porous media, we consider the case of a two-dimensional system consisting of two layers with different convection velocities. Using a lattice generating function formalism and a variety of analytic and numerical techniques, we calculate the asymptotic behavior of the first passage time probability distribution. We show analytically that the asymptotic distribution is a simple exponential in time for any choice of the velocities. The decay constant is given in terms of the largest eigenvalue of an operator related to a half-space Green's function. For the anti-symmetric case of opposite velocities in the layers, we show that the decay constant for system length L crosses over from L -2 behavior in the diffusive limit to L -1 behavior in the convective regime, where the crossover length L* is given in terms of the velocities. We also have formulated a general self-consistency relation, from which we have developed a recursive approach which is useful for studying the short-time behavior

  12. Tracer tests Wairakei

    International Nuclear Information System (INIS)

    McCabe, W.J.; Manning, M.R.; Barry, B.J.

    1980-07-01

    The report summarises the radioactive tracer tests, using iodine-131 and bromine-82, made in the Wairakei geothermal field over the period 1978-80. Injection of tracer into three wells with strong cool water downflows at about 300-400m below ground level, produced strong rapid responses from the only deep wells feeding from about 800-1000m and lying in the south-westerly direction from the injection wells, i.e. parallel to the fault planes. Shallower wells, even though in some cases much closer to the injection well, reacted much more slowly. Velocities, as measured by peak arrival times, as high as 22m/h over 200m and 11m/h over 650m, were found. The flow patterns for the cool water feeds to the production area are discussed

  13. Comparison of Four Mixed Layer Mesoscale Parameterizations and the Equation for an Arbitrary Tracer

    Science.gov (United States)

    Canuto, V. M.; Dubovikov, M. S.

    2011-01-01

    In this paper we discuss two issues, the inter-comparison of four mixed layer mesoscale parameterizations and the search for the eddy induced velocity for an arbitrary tracer. It must be stressed that our analysis is limited to mixed layer mesoscales since we do not treat sub-mesoscales and small turbulent mixing. As for the first item, since three of the four parameterizations are expressed in terms of a stream function and a residual flux of the RMT formalism (residual mean theory), while the fourth is expressed in terms of vertical and horizontal fluxes, we needed a formalism to connect the two formulations. The standard RMT representation developed for the deep ocean cannot be extended to the mixed layer since its stream function does not vanish at the ocean's surface. We develop a new RMT representation that satisfies the surface boundary condition. As for the general form of the eddy induced velocity for an arbitrary tracer, thus far, it has been assumed that there is only the one that originates from the curl of the stream function. This is because it was assumed that the tracer residual flux is purely diffusive. On the other hand, we show that in the case of an arbitrary tracer, the residual flux has also a skew component that gives rise to an additional bolus velocity. Therefore, instead of only one bolus velocity, there are now two, one coming from the curl of the stream function and other from the skew part of the residual flux. In the buoyancy case, only one bolus velocity contributes to the mean buoyancy equation since the residual flux is indeed only diffusive.

  14. Radioactive tracers in Sedimentology

    International Nuclear Information System (INIS)

    Rodrigues, H.T.

    1973-01-01

    First is given a broad description of the uses of radioactive tracers in Sedimentology. The general method is established, including determinations of probability and standard deviation. Following are determined: the response law of the detector, the minimum mass for statistical detection, and the minimum mass for dynamic detection. The granularity is an important variable in these calculations. Final conclusions are given, and results are compared with existing theories

  15. 21 CFR 520.1720a - Phenylbutazone tablets and boluses.

    Science.gov (United States)

    2010-04-01

    ... Section 520.1720a Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES...-mg or 1-g tablets, or 2- or 4-g boluses, in dogs and horses. (2) Nos. 000010 and 059130 for use of 100- or 200-mg or 1-g tablets in dogs and horses. (3) Nos. 000856 and 061623 for use of 100-mg or 1-g...

  16. Journal: Efficient Hydrologic Tracer-Test Design for Tracer ...

    Science.gov (United States)

    Hydrological tracer testing is the most reliable diagnostic technique available for the determination of basic hydraulic and geometric parameters necessary for establishing operative solute-transport processes. Tracer-test design can be difficult because of a lack of prior knowledge of the basic hydraulic and geometric parameters desired and the appropriate tracer mass to release. A new efficient hydrologic tracer-test design (EHTD) methodology has been developed to facilitate the design of tracer tests by root determination of the one-dimensional advection-dispersion equation (ADE) using a preset average tracer concentration which provides a theoretical basis for an estimate of necessary tracer mass. The method uses basic measured field parameters (e.g., discharge, distance, cross-sectional area) that are combined in functional relatipnships that descrive solute-transport processes related to flow velocity and time of travel. These initial estimates for time of travel and velocity are then applied to a hypothetical continuous stirred tank reactor (CSTR) as an analog for the hydrological-flow system to develop initial estimates for tracer concentration, tracer mass, and axial dispersion. Application of the predicted tracer mass with the hydraulic and geometric parameters in the ADE allows for an approximation of initial sample-collection time and subsequent sample-collection frequency where a maximum of 65 samples were determined to be necessary for descri

  17. Transversus Abdominis Plane Catheter Bolus Analgesia after Major Abdominal Surgery

    Directory of Open Access Journals (Sweden)

    Nils Bjerregaard

    2012-01-01

    Full Text Available Purpose. Transversus abdominis plane (TAP blocks have been shown to reduce pain and opioid requirements after abdominal surgery. The aim of the present case series was to demonstrate the use of TAP catheter injections of bupivacaine after major abdominal surgery. Methods. Fifteen patients scheduled for open colonic resection surgery were included. After induction of anesthesia, bilateral TAP catheters were placed, and all patients received a bolus dose of 20 mL bupivacaine 2.5 mg/mL with epinephrine 5 μg/mL through each catheter. Additional bolus doses were injected bilaterally 12, 24, and 36 hrs after the first injections. Supplemental pain treatment consisted of paracetamol, ibuprofen, and gabapentin. Intravenous morphine was used as rescue analgesic. Postoperative pain was rated on a numeric rating scale (NRS, 0–10 at regular predefined intervals after surgery, and consumption of intravenous morphine was recorded. Results. The TAP catheters were placed without any technical difficulties. NRS scores were ≤3 at rest and ≤5 during cough at 4, 8, 12, 18, 24, and 36 hrs after surgery. Cumulative consumption of intravenous morphine was 28 (23–48 mg (median, IQR within the first 48 postoperative hours. Conclusion. TAP catheter bolus injections can be used to prolong analgesia after major abdominal surgery.

  18. Passage of American shad: paradigms and realities

    Science.gov (United States)

    Haro, Alex; Castro-Santos, Theodore

    2012-01-01

    Despite more than 250 years of development, the passage of American shad Alosa sapidissima at dams and other barriers frequently remains problematic. Few improvements in design based on knowledge of the swimming, schooling, and migratory behaviors of American shad have been incorporated into passage structures. Large-scale technical fishways designed for the passage of adult salmonids on the Columbia River have been presumed to have good performance for American shad but have never been rigorously evaluated for this species. Similar but smaller fishway designs on the East Coast frequently have poor performance. Provision of effective downstream passage for both juvenile and postspawning adult American shad has been given little consideration in most passage projects. Ways to attract and guide American shad to both fishway entrances and downstream bypasses remain marginally understood. The historical development of passage structures for American shad has resulted in assumptions and paradigms about American shad behavior and passage that are frequently unsubstantiated by supporting data or appropriate experimentation. We propose that many of these assumptions and paradigms are either unfounded or invalid and that significant improvements to American shad upstream and downstream passage can be made via a sequential program of behavioral experimentation, application of experimental results to the physical and hydraulic design of new structures, and controlled tests of large-scale prototype structures in the laboratory and field.

  19. Tracers and Tracer Testing: Design, Implementation, Tracer Selection, and Interpretation Methods

    Energy Technology Data Exchange (ETDEWEB)

    G. Michael Shook; Shannon L.; Allan Wylie

    2004-01-01

    Conducting a successful tracer test requires adhering to a set of steps. The steps include identifying appropriate and achievable test goals, identifying tracers with the appropriate properties, and implementing the test as designed. When these steps are taken correctly, a host of tracer test analysis methods are available to the practitioner. This report discusses the individual steps required for a successful tracer test and presents methods for analysis. The report is an overview of tracer technology; the Suggested Reading section offers references to the specifics of test design and interpretation.

  20. Heat tracer methods

    Science.gov (United States)

    Healy, Richard W.; Scanlon, Bridget R.

    2010-01-01

    The flow of heat in the subsurface is closely linked to the movement of water (Ingebritsen et al., 2006). As such, heat has been used as a tracer in groundwater studies for more than 100 years (Anderson, 2005). As with chemical and isotopic tracers (Chapter 7), spatial or temporal trends in surface and subsurface temperatures can be used to infer rates of water movement. Temperature can be measured accurately, economically, at high frequencies, and without the need to obtain water samples, facts that make heat an attractive tracer. Temperature measurements made over space and time can be used to infer rates of recharge from a stream or other surface water body (Lapham, 1989; Stonestrom and Constantz, 2003); measurements can also be used to estimate rates of steady drainage through depth intervals within thick unsaturated zones (Constantz et al., 2003; Shan and Bodvarsson, 2004). Several thorough reviews of heat as a tracer in hydrologic studies have recently been published (Constantz et al., 2003; Stonestrom and Constantz, 2003; Anderson, 2005; Blasch et al., 2007; Constantz et al., 2008). This chapter summarizes heat-tracer approaches that have been used to estimate recharge.Some clarification in terminology is presented here to avoid confusion in descriptions of the various approaches that follow. Diffuse recharge is that which occurs more or less uniformly across large areas in response to precipitation, infiltration, and drainage through the unsaturated zone. Estimates of diffuse recharge determined using measured temperatures in the unsaturated zone are referred to as potential recharge because it is possible that not all of the water moving through the unsaturated zone will recharge the aquifer; some may be lost to the atmosphere by evaporation or plant transpiration. Estimated fluxes across confining units in the saturated zone are referred to as interaquifer flow (Chapter 1). Focused recharge is that which occurs directly from a point or line source, such

  1. A customized bolus produced using a 3-dimensional printer for radiotherapy.

    Directory of Open Access Journals (Sweden)

    Shin-Wook Kim

    Full Text Available OBJECTIVE: Boluses are used in high-energy radiotherapy in order to overcome the skin sparing effect. In practice though, commonly used flat boluses fail to make a perfect contact with the irregular surface of the patient's skin, resulting in air gaps. Hence, we fabricated a customized bolus using a 3-dimensional (3D printer and evaluated its feasibility for radiotherapy. METHODS: We designed two kinds of bolus for production on a 3D printer, one of which was the 3D printed flat bolus for the Blue water phantom and the other was a 3D printed customized bolus for the RANDO phantom. The 3D printed flat bolus was fabricated to verify its physical quality. The resulting 3D printed flat bolus was evaluated by assessing dosimetric parameters such as D1.5 cm, D5 cm, and D10 cm. The 3D printed customized bolus was then fabricated, and its quality and clinical feasibility were evaluated by visual inspection and by assessing dosimetric parameters such as Dmax, Dmin, Dmean, D90%, and V90%. RESULTS: The dosimetric parameters of the resulting 3D printed flat bolus showed that it was a useful dose escalating material, equivalent to a commercially available flat bolus. Analysis of the dosimetric parameters of the 3D printed customized bolus demonstrated that it is provided good dose escalation and good contact with the irregular surface of the RANDO phantom. CONCLUSIONS: A customized bolus produced using a 3D printer could potentially replace commercially available flat boluses.

  2. Development of radioisotope tracer technology

    International Nuclear Information System (INIS)

    Jin, Joon Ha; Lee, Myun Joo; Jung, Sung Hee; Park, Soon Chul; Lim, Dong Soon; Kim, Jae Ho; Lee, Jae Choon; Lee, Doo Sung; Cho, Yong Suk; Shin, Sung Kuan

    2000-04-01

    The purpose of this study is to develop the radioisotope tracer technology, which can be used in solving industrial and environmental problems and to build a strong tracer group to support the local industries. In relation to the tracer technology in 1999, experiments to estimate the efficiencies of a sludge digester of a waste water treatment plant and a submerged biological reactor of a dye industry were conducted. As a result, the tracer technology for optimization of facilities related to wastewater treatment has been developed and is believed to contribute to improve their operation efficiency. The quantification of the experimental result was attempted to improve the confidence of tracer technology by ECRIN program which basically uses the MCNP simulation principle. Using thin layer activation technique, wear of tappet shim was estimated. Thin layer surface of a tappet shim was irradiated by proton beam and the correlation between the measured activity loss and the amount of wear was established. The equipment was developed to adjust the energy of proton which collides with the surface of tappet. The tracer project team has participated into the tracer test for estimating the efficiency of RFCC system in SK cooperation. From the experiment the tracer team has obtained the primary elements to be considered for judging the efficiency of RFCC unit. By developing the tracer techniques to test huge industrial units like RFCC, the tracer team will be able to support the local industries that require technical services to solve any urgent trouble. (author)

  3. Chemical Tracer Methods: Chapter 7

    Science.gov (United States)

    Healy, Richard W.

    2017-01-01

    Tracers have a wide variety of uses in hydrologic studies: providing quantitative or qualitative estimates of recharge, identifying sources of recharge, providing information on velocities and travel times of water movement, assessing the importance of preferential flow paths, providing information on hydrodynamic dispersion, and providing data for calibration of water flow and solute-transport models (Walker, 1998; Cook and Herczeg, 2000; Scanlon et al., 2002b). Tracers generally are ions, isotopes, or gases that move with water and that can be detected in the atmosphere, in surface waters, and in the subsurface. Heat also is transported by water; therefore, temperatures can be used to trace water movement. This chapter focuses on the use of chemical and isotopic tracers in the subsurface to estimate recharge. Tracer use in surface-water studies to determine groundwater discharge to streams is addressed in Chapter 4; the use of temperature as a tracer is described in Chapter 8.Following the nomenclature of Scanlon et al. (2002b), tracers are grouped into three categories: natural environmental tracers, historical tracers, and applied tracers. Natural environmental tracers are those that are transported to or created within the atmosphere under natural processes; these tracers are carried to the Earth’s surface as wet or dry atmospheric deposition. The most commonly used natural environmental tracer is chloride (Cl) (Allison and Hughes, 1978). Ocean water, through the process of evaporation, is the primary source of atmospheric Cl. Other tracers in this category include chlorine-36 (36Cl) and tritium (3H); these two isotopes are produced naturally in the Earth’s atmosphere; however, there are additional anthropogenic sources of them.

  4. Radionuclides as tracers

    International Nuclear Information System (INIS)

    Ganatra, R.D.

    1992-01-01

    Importance of radioisotopes in medicine is because of their two characteristics: their biological behaviour is identical to their stable counterparts, and because they are radioactive their emissions can be detected by a suitable instrument. All isotopes of iodine will behave in the same way and will concentrate in the thyroid gland. There is no way of detecting the stable, natural iodine in the thyroid gland, but the presence of radioactive iodine can be detected externally in vivo by a detector. Thus, the radioactive iodine becomes a tracer, a sport of a spy, which mimics the behaviour of natural iodine and relays information to a detector. The radioactive tracers are popular because of the ease with which they can be detected in vivo and the fact that the measurement of their presence in the body can be in quantitative terms. The measurement can be very accurate and sensitive. Whenever the measurements can be done in vivo, the information is obtained in dynamic terms, as it is happening, as if the physiological events become transparent

  5. Tracer sa route, en toute intransparence numérique ?

    Directory of Open Access Journals (Sweden)

    Philippe Vidal

    2015-12-01

    Full Text Available « Comme l’intransparence des vitres ferait tache dans une habitation et l’attristerait en obstruant le passage du regard, on a dû chercher au moyen de voir au travers sans être vu, et l’on a inventé le verre mousseline. » L’expression « tracer sa route » est souvent utilisée dans un sens familier. Elle signifie, ordinairement, partir à l’aventure, sans se soucier des éventuelles contraintes et conséquences d’un tel choix, qu’elles soient sociales, matérielles ou familiales. A l’image des trav...

  6. Radionuclide esophageal transit of a liquid bolus: A reappraisal

    International Nuclear Information System (INIS)

    Holloway, R.H.; Lange, R.C.; Magyar, L.; Greene, R.; McCallum, R.W.

    1984-01-01

    Measurement of radionuclide esophageal transit (RT) using a liquid bolus has been suggested as a screening test for esophageal motor disorders (EMD). The authors prospectively evaluated RT in 49 patients referred for esophageal manometry. Ten subjects with normal manometry served as controls. RT was performed using two 10 ml boluses of water labeled with 250 μCi /sup 99m/Tc-sulfur colloid. Patients were studied supine and the swallow sequences framed in 1 second intervals. Transit time was measured from the time of entry to the time of exit from the esophagus. Mean transit time in normal subjects was 9.1 +- 2.1 (SD) sec. The test was abnormal if the transit time was prolonged (> 15 sec) in at least 1 of 2 swallows. RT agreed with manometry in 36/49 patients (75%), including 9/9 achalasics, 3/3 diffuse esophageal spasm, 3/7 'nutcracker esophagus' and 7/8 non-specific motor disorders (NSMD). 4/18 patients with normal manometry had abnormal RT. 9/31 patients with abnormal manometry had normal RT, including 4/7 nutcracker esophagus, 3/3 hypertrensive LES, 1/1 scleroderma and 1/8 NSMD. Sensitivity of RT was 70% and specificity 77%. The false positive rate was 15% and the false negative rate 39%. The authors conclude the following: 1) RT identifies patients with absent or impaired peristalsis; 2) There is substantial incidence of false negatives among patients with manometric disorders but normal peristalsis; and 3) Abnormal RT did occur in some patients with normal menometry. RT using a liquid bolus may not be sensitive enough as a screening test for EMD, but it may be an important adjunct to manometry

  7. Iodine 123-antipyrine. A diffusible tracer for brain exploration

    International Nuclear Information System (INIS)

    Dantonel-Mathieu, Evelyne.

    1978-09-01

    Iodine 123-labelled iodoantipyrine is a liposoluble diffusible tracer which crosses the blood-brain barrier intact. Its build-up in brain tissue is proportional to the regional blood flow. Its behavior was studied in undervascularised brain lesions and in cases where research with traditional radioactive tracers (99mTc and its different vectors for example) has proved limited. Because of the great diffusibility of iodoantipyrine a brain parenchyma image is obtained within minutes after its injection, and this by the use of a non-invasive technique and under good gamma-camera exploration conditions. 81 brain explorations including 11 standards have been carried out on subjects averaging 51,2 years old; these examinations took place in three nuclear medicine centres. The 123 I iodoantipyrine used in each nuclear medicine centre is supplied by the CEA. Iodoantipyrine is labelled with a good yield (>98%) checked by chromatography by means of a CEA kit. After intraveinous injection of 4 to 6 mCi iodine-123 iodoantipyrine, a dynamic study (from 0 to 60 seconds) of the tracer passage in the brain tissue may be followed by static images taken in the next minutes according to a standard procedure. The table of results shows the major interest of this tracer for the exploration of vascular accidents with ischemic lesions, especially in the early phase of the accident. The lesion appears as a hypoactive zone and this lack of perfusion lasts for some minutes after the injection [fr

  8. MR liver imaging after bolus administration of Teslascan

    International Nuclear Information System (INIS)

    Costa, S.; Marti-Bonmati, L.; Delgado, F.; Torregrosa, A.

    2003-01-01

    Mn-DPDP (Teslascan. Amersham-Health) improves the detection of small hepatic lesions and the accuracy with which certain focal lesions can be characterized. Slow infusion (2-3 ml per minute) is the accepted European standard for its administration. Our aim was to evaluate the efficiency of bolus administration. A prospective MR evaluation at 0.5 was performed on 31 consecutive patients. A GE T1 sequence was performed on all before contrast administration. Teslascan was administered by rapid intravenous infusion (=1 ml/s), and the GE sequence was repeated and completed by an STIR sequence. Correlations between presence of cirrhosis and enhancement pattern of hepatic parenchyma, number of lesions detected before and after bolus administration, as well as lesion histology and degree of enhancement were all analyzed. Adverse clinical reactions as reported by patients were also noted. Cirrhotic liver was found in 49% of the patients. Enhancement was mainly heterogeneous with hypointense areas and heterogeneous with hypointense areas together with more greatly enhanced regenerative nodules. Enhancement of cirrhotic livers was homogeneous in a third of the cases. Non-cirrhotic patients exhibited a homogeneous hepatic mass in most cases,ith only one liver showing heterogeneous enhancement containing hypointense bands caused by necrotic debris having resulted from treated metastases. Enhancement pattern differences between cirrhotic and non-cirrhotic patients were statistically significant (p=0.001). In 20 of the 31 patients, solid focal lesions were detected. Sequences performed after bolus administration of contrast media detected more lesions than did those before administration. Combination of both post-administration sequences (T1 and STIR) detected the most lesions, with differences between it and pre-administration sequences being statistically significant (p=0.0014). There was observed a varying degree of lesion enhancement. Such variability was associated with the

  9. Effect of contrast media iodine concentration on bolus tracking

    International Nuclear Information System (INIS)

    Ishihara, Toshihiro; Hayashi, Takayuki; Nakaya, Yoshihiro; Naoi, Kuniji; Ikeno, Naoya; Kobayashi, Tatsushi; Satake, Mitsuo

    2006-01-01

    Computer-assisted bolus tracking has been confirmed to be a useful technique in computed tomography (CT) imaging and allows images to be captured with automated timing. The inflow of the contrast medium is monitored, and when the contrast medium reaches a predetermined level, CT image capture starts automatically. However, it has been shown that the preset threshold value of contrast medium is affected by its iodine concentration, which causes variations in image capture times. Greater speed in current multislice CT imaging requires that medical technicians pay more attention to setting the timing of image capture during venous examinations by taking into account the iodine concentration in contrast media. (author)

  10. The influence of a solid and liquid bolus on food-stimulated gastroesophageal reflux

    Energy Technology Data Exchange (ETDEWEB)

    Naeser, A.; Behrens, J.K.; Vejen-Christiansen, L.; Funch-Jensen, P.; Thommesen, P. (Aarhus Kommunehospital (Denmark). GI Motility Lab. Aarhus Kommunehospital (Denmark). Dept. of Diagnostic Radiology R)

    1992-02-01

    Using a radiological method to demonstrate food-stimulated gastroesophageal reflux (GER), a comparative study was carried out employing a solid, already validated bolus versus a liquid one. One hundred and four consecutive patients received both a solid and a liquid bolus in randomized order. GER was observed in 37 (35.6%) patients receiving the solid bolus versus 28 (26.9%) with the liquid one. This means that the solid bolus provokes significantly more reflux (P<0.02). GER, grade II (reflux above the level of the carina), occurred equally often as a result of both types of bolus, however. The study suggests that significant, food-stimulated GER is independent of the consistency of the foodstuffs and may be detected employing a liquid bolus. This result might be used in the examination of infants for GER, using milk as a food stimulus. (orig.).

  11. Passage relevance models for genomics search

    Directory of Open Access Journals (Sweden)

    Frieder Ophir

    2009-03-01

    Full Text Available Abstract We present a passage relevance model for integrating syntactic and semantic evidence of biomedical concepts and topics using a probabilistic graphical model. Component models of topics, concepts, terms, and document are represented as potential functions within a Markov Random Field. The probability of a passage being relevant to a biologist's information need is represented as the joint distribution across all potential functions. Relevance model feedback of top ranked passages is used to improve distributional estimates of query concepts and topics in context, and a dimensional indexing strategy is used for efficient aggregation of concept and term statistics. By integrating multiple sources of evidence including dependencies between topics, concepts, and terms, we seek to improve genomics literature passage retrieval precision. Using this model, we are able to demonstrate statistically significant improvements in retrieval precision using a large genomics literature corpus.

  12. Skeptical notes on a physics of passage.

    Science.gov (United States)

    Huggett, Nick

    2014-10-01

    This paper investigates the mathematical representation of time in physics. In existing theories, time is represented by the real numbers, hence their formal properties represent properties of time: these are surveyed. The central question of the paper is whether the existing representation of time is adequate, or whether it can or should be supplemented: especially, do we need a physics incorporating some kind of "dynamical passage" of time? The paper argues that the existing mathematical framework is resistant to such changes, and might have to be rejected by anyone seeking a physics of passage. Then it rebuts two common arguments for incorporating passage into physics, especially the claim that it is an element of experience. Finally, the paper investigates whether, as has been claimed, causal set theory provides a physics of passage. © 2014 New York Academy of Sciences.

  13. Brook trout passage performance through culverts

    Science.gov (United States)

    Goerig, Elsa; Castro-Santos, Theodore R.; Bergeron, Normand

    2016-01-01

    Culverts can restrict access to habitat for stream-dwelling fishes. We used passive integrated transponder telemetry to quantify passage performance of >1000 wild brook trout (Salvelinus fontinalis) attempting to pass 13 culverts in Quebec under a range of hydraulic and environmental conditions. Several variables influenced passage success, including complex interactions between physiology and behavior, hydraulics, and structural characteristics. The probability of successful passage was greater through corrugated metal culverts than through smooth ones, particularly among smaller fish. Trout were also more likely to pass at warmer temperatures, but this effect diminished above 15 °C. Passage was impeded at higher flows, through culverts with steep slopes, and those with deep downstream pools. This study provides insight on factors influencing brook trout capacity to pass culverts as well as a model to estimate passage success under various conditions, with an improved resolution and accuracy over existing approaches. It also presents methods that could be used to investigate passage success of other species, with implications for connectivity of the riverscape.

  14. Assessment of bolus transit with intraluminal impedance measurement in patients with esophageal motility disorders.

    Science.gov (United States)

    Bogte, A; Bredenoord, A J; Oors, J; Siersema, P D; Smout, A J P M

    2015-10-01

    The clinical management of patients with non-obstructive dysphagia is notoriously difficult. Esophageal impedance measurement can be used to measure esophageal bolus transit without the use of radiation exposure to patients. However, validation of measurement of bolus transit with impedance monitoring has only been performed in healthy subjects with normal motility and not in patients with dysphagia and esophageal motility disorders. The aim was, therefore, to investigate the relationship between transit of swallowed liquid boluses in healthy controls and in patients with dysphagia. Twenty healthy volunteers and 20 patients with dysphagia underwent concurrent impedance measurement and videofluoroscopy. Each subject swallowed five liquid barium boluses. The ability of detecting complete or incomplete bolus transit by means of impedance measurement was assessed, using radiographic bolus transit as the gold standard. Impedance monitoring recognized stasis and transit in 80.5% of the events correctly, with 83.9% of bolus transit being recognized and 77.2% of stasis being recognized correctly. In controls 79.8% of all swallows were scored correctly, whereas in patients 81.3% of all swallows were scored correctly. Depending on the contractility pattern, between 77.0% and 94.3% of the swallows were scored correctly. Impedance measurement can be used to assess bolus clearance patterns in healthy subjects, but can also be used to reliably assess bolus transit in patients with dysphagia and motility disorders. © 2015 John Wiley & Sons Ltd.

  15. Efficacy of a Targeted Drug Delivery on-Demand Bolus Option for Chronic Pain.

    Science.gov (United States)

    Bolash, Robert B; Niazi, Tariq; Kumari, Meera; Azer, Gerges; Mekhail, Nagy

    2018-03-01

    Intrathecal targeted drug delivery systems historically required physician office visits for dose adjustment to manage fluctuating pain. A wireless device now enables patients to supplement their basal intrathecal infusion with a programmed on-demand bolus dose. We sought to quantify the change in oral breakthrough opioid need associated with the use of an intrathecal bolus in comparison to those treated with the basal infusion alone. Demographic, dosage, bolus usage and longevity data were extracted from the historical medical record of 69 patients (18/51 bolus/nonbolus) followed continuously at our center. Medication consumption and Pain Disability Index measures were obtained at baseline and most recent follow-up. Among patients with the bolus option, only 2 (11%; confidence interval [CI] 0% to 26%) continued to require oral opiates to manage breakthrough pain compared to 29 (57%; CI 43% to 71%) without the bolus option. The Pain Disability Index score decreased by 19% in patients with the bolus option and by 25% in those with the basal infusion. Total daily intrathecal opioid intake was 34% lower in the group with the bolus device. Utilizing an intrathecal bolus to treat incident pain was a safe way to manage unpredictable breakthrough pain and may represent a cost-saving opportunity by eliminating the need for oral analgesic medications. © 2017 World Institute of Pain.

  16. Radon as geological tracer

    Energy Technology Data Exchange (ETDEWEB)

    Lacerda, T.; Anjos, R.M. [Universidade Federal Fluminense (UFF), Niteroi, RJ (Brazil). Inst. de Fisica; Valladares, D.L.; Rizzotto, M.; Velasco, H.; Ayub, J. Juri [Universidad Nacional de San Luis (Argentina). Inst. de Matematica Aplicada San Luis (IMASL); Silva, A.A.R. da; Yoshimura, E.M. [Universidade de Sao Paulo (IF/USP), SP (Brazil). Inst. de Fisica

    2012-07-01

    Full text: This work presents measurements of {sup 222}Rn levels performed in La Carolina gold mine and Los Condores tungsten mine at the province of San Luis, Argentina, today used for tourist visitation, and can evaluate the potential use of such radioactive noble gas as tracer or marker for geological processes in underground environments. By concentrations of {sup 40}K, {sup 232}Th and {sup 23}'8U were also measured in the walls of tunnels were determined the rocks mineral composition, what indicated that the mines have the same composition. In this sense, we used nuclear trace plastic detectors CR-39, gamma spectrometry of rock samples and Geiger-Muller (GM) monitors The patterns of radon gas transportation processes revealed that La Carolina could be interpreted through a model based on a radioactive gas confined into a single entrance tube, with constant cross section and air velocity. Los Condores, which has a second main entrance, could be interpreted through a model based on a radioactive gas confined into a two entrance tube, allowing a chimney effect for air circulation. The results showed the high potential of using {sup 222}Rn as a geological tracer. In what concerns the occupational hazard, in summer (time of more intense tourist activity in the mine) La Carolina presented a mean concentration of the radioactive noble gas that exceeds in four times the action level of 1,5 kBq m{sup -3} recommended by the International Commission of Radiological Protection (ICRP). The chimney effect shows the low mean concentration of radon in Los Condores. (author)

  17. Radon as geological tracer

    International Nuclear Information System (INIS)

    Lacerda, T.; Anjos, R.M.; Silva, A.A.R. da; Yoshimura, E.M.

    2012-01-01

    Full text: This work presents measurements of 222 Rn levels performed in La Carolina gold mine and Los Condores tungsten mine at the province of San Luis, Argentina, today used for tourist visitation, and can evaluate the potential use of such radioactive noble gas as tracer or marker for geological processes in underground environments. By concentrations of 40 K, 232 Th and 23 '8U were also measured in the walls of tunnels were determined the rocks mineral composition, what indicated that the mines have the same composition. In this sense, we used nuclear trace plastic detectors CR-39, gamma spectrometry of rock samples and Geiger-Muller (GM) monitors The patterns of radon gas transportation processes revealed that La Carolina could be interpreted through a model based on a radioactive gas confined into a single entrance tube, with constant cross section and air velocity. Los Condores, which has a second main entrance, could be interpreted through a model based on a radioactive gas confined into a two entrance tube, allowing a chimney effect for air circulation. The results showed the high potential of using 222 Rn as a geological tracer. In what concerns the occupational hazard, in summer (time of more intense tourist activity in the mine) La Carolina presented a mean concentration of the radioactive noble gas that exceeds in four times the action level of 1,5 kBq m -3 recommended by the International Commission of Radiological Protection (ICRP). The chimney effect shows the low mean concentration of radon in Los Condores. (author)

  18. Distribution and mixing of a liquid bolus in pleural space.

    Science.gov (United States)

    Bodega, Francesca; Tresoldi, Claudio; Porta, Cristina; Zocchi, Luciano; Agostoni, Emilio

    2006-02-28

    Distribution and mixing time of boluses with labeled albumin in pleural space of anesthetized, supine rabbits were determined by sampling pleural liquid at different times in various intercostal spaces (ics), and in cranial and caudal mediastinum. During sampling, lung and chest wall were kept apposed by lung inflation. This was not necessary in costo-phrenic sinus. Here, 10 min after injection, lung inflation increased concentration of labeled albumin by 50%. Lung inflation probably displaces some pleural liquid cranio-caudally, increasing labeled albumin concentration caudally to injection point (6th ics), and decreasing it cranially. Boluses of 0.1-1 ml did not preferentially reach mediastinal regions, as maintained by others. Time for an approximate mixing was approximately 1 h for 0.1 ml, and approximately 30 min for 1 ml. This relatively long mixing time does not substantially affect determination of contribution of lymphatic drainage through stomata to overall removal of labeled albumin from 0.3 ml hydrothoraces lasting 3 h [Bodega, F., Agostoni, E., 2004. Contribution of lymphatic drainage through stomata to albumin removal from pleural space. Respir. Physiol. Neurobiol. 142, 251-263].

  19. Kinetic modelling of [123I]CNS 1261--a potential SPET tracer for the NMDA receptor

    International Nuclear Information System (INIS)

    Erlandsson, Kjell; Bressan, Rodrigo A.; Mulligan, Rachel S.; Gunn, Roger N; Cunningham, Vincent J.; Owens, Jonathan; Wyper, David; Ell, Peter J.; Pilowsky, Lyn S.

    2003-01-01

    N-(1-napthyl)-N'-(3-[ 123 I]-iodophenyl)-N-methylguanidine ([ 123 I]CNS 1261) is a novel SPET ligand developed for imaging the NMDA receptor intra-channel MK 801/PCP/ketamine site. Data was acquired in 7 healthy volunteers after bolus injection of [ 123 I]CNS 1261. Kinetic modeling showed reversible tracer binding. Arterial and venous time-activity curves overlapped after 90 min. The rank order of binding was: Thalamus > striatum > cortical regions > white matter. This distribution concurs with [ 11 C]-ketamine and [ 18 F]-memantine PET studies . These data provide a methodological basis for further direct in vivo challenge studies

  20. Neuroreceptor quantitation in vivo by the steady-state principle using constant infusion or bolus injection of radioactive tracers

    DEFF Research Database (Denmark)

    Lassen, N A

    1992-01-01

    The approaches hitherto used for measuring the kinetic constants Kd and Bmax of neuroreceptors in vivo all violate the steady state of the system. This complicates the kinetic analysis as approximations must be made, introducing errors of unknown magnitude. The present study presents the theory...

  1. Tracer dating and ocean ventilation

    International Nuclear Information System (INIS)

    Thiele, G.; Sarmiento, J.L.

    1990-01-01

    The interpretation of transient tracer observations depends on difficult to obtain information on the evolution in time of the tracer boundary conditions and interior distributions. Recent studies have attempted to circumvent this problem by making use of a derived quantity, age, based on the simultaneous distribution of two complementary tracers, such as tritium and its daughter, helium 3. The age is defined with reference to the surface such that the boundary condition takes on a constant value of zero. The authors use a two-dimensional model to explore the circumstances under which such a combination of conservation equations for two complementary tracers can lead to a cancellation of the time derivative terms. An interesting aspect of this approach is that mixing can serve as a source or sink of tracer based age. The authors define an idealized ventilation age tracer that is conservative with respect to mixing, and they explore how its behavior compares with that of the tracer-based ages over a range of advective and diffusive parameters

  2. Bolus fluid therapy and sodium homeostasis in paediatric gastroenteritis.

    Science.gov (United States)

    Freedman, Stephen B; Geary, Denis F

    2013-03-01

    The study aims to assess the risk of developing hyponatraemia when large-volume bolus fluid rehydration therapy is administered. We conducted a prospective randomised study in a tertiary-care centre emergency department. Participants included children with gastroenteritis and dehydration requiring intravenous rehydration. They were randomised to receive 60 mL/kg (large) or 20 mL/kg (standard) 0.9% saline bolus followed by maintenance 0.9% saline for 3 h. Biochemical tests were performed at baseline and 4 h. The primary outcome measure was the development of hyponatraemia at 4 h. Secondary outcome measures were (i) change in sodium relative to baseline value; (ii) magnitude of decrease among those who experienced a decrease; (iii) risk of hypernatraemia; (iv) correlations between urine parameters and hyponatraemia; and (v) fluid overload. Eighty-four of 224 (38%) participants were hyponatraemic at baseline. At 4 h, 22% (48/217) had a dysnatraemia, and similar numbers of children were hyponatraemic in both groups: large (23% (26/112)) versus standard (21% (22/105)) (P = 0.69). Among initially hyponatraemic children, 63% (30/48) who received large-volume rehydration and 44% (15/34) of those administered standard rehydration were isonatraemic at 4 h (P = 0.10). Overall, children who received 60 mL/kg experienced a larger mean increase (1.6 ± 2.4 mEq/L vs. 0.9 ± 2.2 mEq/L; P = 0.04) and were less likely to experience a sodium decrease of ≥2 mEq/L (8/112 vs. 17/105; P = 0.04) than those administered 20 mL/kg. Large-volume bolus rehydration therapy with 0.9% saline is safe. It does not promote the development of hyponatraemia over the short term, but hastens the resolution of baseline hyponatraemia. © 2013 The Authors. Journal of Paediatrics and Child Health © 2013 Paediatrics and Child Health Division (Royal Australasian College of Physicians).

  3. Correlations between aorto-popliteal bolus transit speed and aortic and popliteal bolus transit time during CT angiography of aortoiliac and lower extremity arteries

    Energy Technology Data Exchange (ETDEWEB)

    Nakaya, Yasuhiro, E-mail: y-nakaya@radiol.med.osaka-u.ac.jp [Department of Radiology, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita City, Osaka 565-0871 (Japan); Kim, Tonsok; Hori, Masatoshi; Onishi, Hiromitsu; Nakamoto, Atsushi; Tsuboyama, Takahiro; Maeda, Noboru; Higashihara, Hiroki; Tomoda, Kaname; Nakamura, Hironobu [Department of Radiology, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita City, Osaka 565-0871 (Japan)

    2011-08-15

    Purpose: The purpose of this study was to investigate correlations between the aorto-popliteal bolus transit speed and aortic and popliteal bolus transit time in order to evaluate the possibility for prediction of bolus transit speed by single test injection technique. Materials and methods: Approval was obtained from our institutional review board for this study, which included 42 patients, from all of whom written informed consent was obtained. Low-dose serial CT scanning after injection of 12 ml contrast material (300 mg/ml) at a rate of 3 ml/s followed by saline flush was performed twice, first at the level of the upper abdomen and second at the level of the knee joint. The times needed to reach peak enhancement of the upper abdominal aorta (T-aorta) and bilateral popliteal arteries (T-popliteal) were obtained, and aorto-popliteal bolus transit speeds between the abdominal aorta and popliteal arteries were calculated. ABI was recorded for the bilateral feet. The Pearson's product-moment correlation coefficient was used to investigate the correlation between the bolus transit speed and T-aorta, T-popliteal, ABI, and patient age. Result: The respective correlation coefficients for bolus transit speed on the one hand and T-aorta, T-popliteal, ABI, patient age on the other were -0.50, -0.84, 0.36, and -0.52. Conclusion: The time to peak enhancement for popliteal arteries showed the strongest correlation with aorto-popliteal bolus transit speeds, and was considered to be the most accurate predictor for aorto-popliteal bolus transit speeds.

  4. Tracer research in process engineering

    International Nuclear Information System (INIS)

    Iller, E.

    1992-01-01

    The book is a review of modern applications of tracer techniques in chemical and process engineering studies. The next topics have been extensively presented: 1) media flow through apparatus; 2) the tracers in the study of media flow dynamics through apparatus; 3) mathematical interpretation of experimental data from impulse-response method; 4) the models of media flow through chemical reactors and apparatus; 5) radiotracers in mass transport study; 6) examples of practical applications of tracer methods in industrial objects. 84 refs, 96 figs, 31 tabs

  5. Tracer dispersion - experiment and CFD

    International Nuclear Information System (INIS)

    Zitny, R.

    2004-01-01

    Description of tracer distribution by means of dispersion models is a method successfully used in process engineering for fifty years. Application of dispersion models in reactor engineering for characterization of flows in column apparatus, heat exchangers, etc. is summarized and experimental tracer techniques as well as CFD methods for dispersion coefficients evaluation are discussed. Possible extensions of thermal axial dispersion model (ADM) and a core-wall ADM model suitable for description of tracer dispersion in laminar flows are suggested as well as CFD implementation as 1D finite elements. (author)

  6. Meteorological tracers in regional planning

    International Nuclear Information System (INIS)

    Mueller, K.H.

    1974-11-01

    Atmospheric tracers can be used as indicators to study both the ventilation of an urban region and its dispersion meteorology for air pollutants. A correlation analysis applied to the space-time dependent tracer concentrations is able to give transfer functions, the structure and characteristic parameters of which describe the meteorological and topographical situation of the urban region and its surroundings in an integral manner. To reduce the number of persons usually involved in a tracer experiment an automatic air sampling system had to be developed

  7. Proceedings of the atmospheric tracers and tracer application workshop

    International Nuclear Information System (INIS)

    Barr, S.; Gedayloo, T.

    1979-12-01

    In addition to presentations by participating members a general discussion was held in order to summarize and outline the goals and objectives of the workshop. A number of new low level background tracers such as heavy methanes, perfluorocarbons, multiply labeled isotopes such as 13 C 18 O 2 , helium 3, in addition to sample collection techniques and analytical methods for various tracers were discussed. This report is a summary of discussions and papers presented at this workshop

  8. Qualitative indices and enhancement rate of CT pulmonary angiography in patients with suspected pulmonary embolism: Comparison between test bolus and bolus-tracking methods

    Directory of Open Access Journals (Sweden)

    Maryam Moradi

    2016-01-01

    Full Text Available Background: The aim of the present study was to assess the qualitative indices and enhancement rate of computed tomographic pulmonary angiography (CTPA in patients with suspected pulmonary embolism using Test bolus and Bolus-tracking techniques. Materials and Methods: Fifty-two patients with suspected pulmonary embolism that passed informed consent were randomly divided in the two groups. In each group, demographic characteristics, qualitative indices, and enhancement rate of CTPA were recorded. Results: The diagnostic result obtained in majority of the participants in the two groups (88.5 % in Test bolus group vs. 73.1% in the Bolus tracking group. In the case of quantitative variables, no statistically significant differences were found between the groups (P > 0.05. The only statistically significant difference between the two groups is average of "X-ray dose". Conclusion: The results of our study show that there is no statistically significant difference between the Bolus Tracking and Test Bolus techniques for producing more homogeneous enhancement.

  9. 21 CFR 520.1242b - Levamisole hydrochloride tablet or oblet (bolus).

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Levamisole hydrochloride tablet or oblet (bolus... § 520.1242b Levamisole hydrochloride tablet or oblet (bolus). (a) Chemical name. (-)-2,3,5,6-Tetrahydro... using in severely debilitated animals. (2) It is used in a tablet for sheep as follows: (i) Amount. 0...

  10. Sensation of stasis is poorly correlated with impaired esophageal bolus transport

    NARCIS (Netherlands)

    Bogte, A.; Bredenoord, A. J.; Oors, J.; Siersema, P. D.; Smout, A. J. P. M.

    2014-01-01

    It is common belief that symptoms of patients with non-obstructive dysphagia are the result of impaired bolus clearance in the esophagus, usually caused by esophageal motility disorders. We therefore investigated the relationship between transit of swallowed boluses and the symptom dysphagia. Twenty

  11. Insertable fluid flow passage bridgepiece and method

    Science.gov (United States)

    Jones, Daniel O.

    2000-01-01

    A fluid flow passage bridgepiece for insertion into an open-face fluid flow channel of a fluid flow plate is provided. The bridgepiece provides a sealed passage from a columnar fluid flow manifold to the flow channel, thereby preventing undesirable leakage into and out of the columnar fluid flow manifold. When deployed in the various fluid flow plates that are used in a Proton Exchange Membrane (PEM) fuel cell, bridgepieces of this invention prevent mixing of reactant gases, leakage of coolant or humidification water, and occlusion of the fluid flow channel by gasket material. The invention also provides a fluid flow plate assembly including an insertable bridgepiece, a fluid flow plate adapted for use with an insertable bridgepiece, and a method of manufacturing a fluid flow plate with an insertable fluid flow passage bridgepiece.

  12. MO-H-19A-03: Patient Specific Bolus with 3D Printing Technology for Electron Radiotherapy

    International Nuclear Information System (INIS)

    Zou, W; Swann, B; Siderits, R; McKenna, M; Khan, A; Yue, N; Zhang, M; Fisher, T

    2014-01-01

    Purpose: Bolus is widely used in electron radiotherapy to achieve desired dose distribution. 3D printing technologies provide clinicians with easy access to fabricate patient specific bolus accommodating patient body surface irregularities and tissue inhomogeneity. This study presents the design and the clinical workflow of 3D printed bolus for patient electron therapy in our clinic. Methods: Patient simulation CT images free of bolus were exported from treatment planning system (TPS) to an in-house developed software package. Bolus with known material properties was designed in the software package and then exported back to the TPS as a structure. Dose calculation was carried out to examine the coverage of the target. After satisfying dose distribution was achieved, the bolus structure was transferred in Standard Tessellation Language (STL) file format for the 3D printer to generate the machine codes for printing. Upon receiving printed bolus, a quick quality assurance was performed with patient resimulated with bolus in place to verify the bolus dosimetric property before treatment started. Results: A patient specific bolus for electron radiotherapy was designed and fabricated in Form 1 3D printer with methacrylate photopolymer resin. Satisfying dose distribution was achieved in patient with bolus setup. Treatment was successfully finished for one patient with the 3D printed bolus. Conclusion: The electron bolus fabrication with 3D printing technology was successfully implemented in clinic practice

  13. MO-H-19A-03: Patient Specific Bolus with 3D Printing Technology for Electron Radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Zou, W; Swann, B; Siderits, R; McKenna, M; Khan, A; Yue, N; Zhang, M [Rutgers University, New Brunswick, NJ (United States); Fisher, T [Memorial Medical Center, Modesto, CA (United States)

    2014-06-15

    Purpose: Bolus is widely used in electron radiotherapy to achieve desired dose distribution. 3D printing technologies provide clinicians with easy access to fabricate patient specific bolus accommodating patient body surface irregularities and tissue inhomogeneity. This study presents the design and the clinical workflow of 3D printed bolus for patient electron therapy in our clinic. Methods: Patient simulation CT images free of bolus were exported from treatment planning system (TPS) to an in-house developed software package. Bolus with known material properties was designed in the software package and then exported back to the TPS as a structure. Dose calculation was carried out to examine the coverage of the target. After satisfying dose distribution was achieved, the bolus structure was transferred in Standard Tessellation Language (STL) file format for the 3D printer to generate the machine codes for printing. Upon receiving printed bolus, a quick quality assurance was performed with patient resimulated with bolus in place to verify the bolus dosimetric property before treatment started. Results: A patient specific bolus for electron radiotherapy was designed and fabricated in Form 1 3D printer with methacrylate photopolymer resin. Satisfying dose distribution was achieved in patient with bolus setup. Treatment was successfully finished for one patient with the 3D printed bolus. Conclusion: The electron bolus fabrication with 3D printing technology was successfully implemented in clinic practice.

  14. Tracer studies with aortic infusion result in improper tracer distribution

    International Nuclear Information System (INIS)

    Wisneski, J.A.; Brooks, G.A.; Neese, R.A.; Stanley, W.C.; Morris, D.L.; Gertz, E.W.

    1986-01-01

    It has been suggested that lactate turnover can be accurately assessed by infusing radioactive lactate tracer into the aorta and sampling blood in the vena cava. However, there may be streaming of newly infused tracer in the aorta, resulting in a nonuniform arterial specific activity (SA). Furthermore vena caval blood may not be representative of mixed venous blood. The authors examined this problem in 7 anesthetized dogs with sampling catheters in the pulmonary (PA), carotid (CA), and femoral (FA) arteries, and the superior (SVC) and inferior (IVC) vena cavi. [1- 14 C]lactate was continuously infused into the left ventricle through a catheter introduced through the femoral artery. The same SA (dpm/μmol) was found in the CA and FA, indicating adequate mixing of newly infused tracer with trace. Three dogs showed differences between SVC, IVC and PA, suggesting a mixed venous sample can not be obtained from the VC. When the catheter was moved into the aorta, wide differences in SA appeared between the CA and FA, clearly reflecting streaming of tracer. These differences also appeared in the SVC and IVC. In conclusion, adequate mixing does not occur between tracer and trace in arterial blood with aortic infusion. Further, VC sampling will not give a consistent mixed venous SA. Therefore, for practical reasons, aortic tracer infusion with vena caval sampling will lead to erroneous turnover values

  15. Radiation dosimetry for bolus administration of oxygen-15-water

    International Nuclear Information System (INIS)

    Brihaye, C.; Depresseux, J.C.; Comar, D.

    1995-01-01

    The authors describe the development of a biokinetic model which permits an estimation of organ activities and the dosimetry of a bolus of 15 O-water. The aim of this study was to estimate time-activity functions and deduce the cumulated activities in different organs so that the radiation absorbed dose values can be estimated. The model used includes the right heart chambers, lungs, left heart chambers, brain, liver, kidneys, muscles, gasrointestinal tract and the remainder of the body. Activity in an organ will decay by physical decay with the decay constant, γ, and can diffuse in the organ. An exception is the heart, where blood is ejected from the heart chambers. Depending on the location of the organ in relation to the blood sampling point, organ activities can be calculated by convolution or deconvolution. The radiation absorbed dose values were estimated and an effective dose equivalent H E of 1.16 μSv/MBq (4.32 mrem/mCi) as well as an effective dose E of 1.15 μSv/MBq (4.25 mrem/mCi) were calculated. The cumulated activities in select organs measured by PET gave good agreement with the values calculated by this model. The values of effective dose equivalent and effective dose for bolus administration of 15 O-water calculated from the absorbed doses estimated by the proposed kinetic model are almost three times higher than those previously published. A total of 8700 MBq (235 mCi) of 15 O-water can be administered if an effective dose of 10 mSv (1 rem) is accepted. 32 refs., 5 figs., 2 tabs

  16. First Passage Time Intervals of Gaussian Processes

    Science.gov (United States)

    Perez, Hector; Kawabata, Tsutomu; Mimaki, Tadashi

    1987-08-01

    The first passage time problem of a stationary Guassian process is theretically and experimentally studied. Renewal functions are derived for a time-dependent boundary and numerically calculated for a Gaussian process having a seventh-order Butterworth spectrum. The results show a multipeak property not only for the constant boundary but also for a linearly increasing boundary. The first passage time distribution densities were experimentally determined for a constant boundary. The renewal functions were shown to be a fairly good approximation to the distribution density over a limited range.

  17. First passage time probability in risk analysis

    International Nuclear Information System (INIS)

    Karmeshu; Ariaratnam, S.T.

    1982-01-01

    Many natural phenomena are subject to uncertain fluctuations due to a variety of internal or external factors. These phenomena can be described using stochastic models. An important quantity of interest involves the time lapse before some variables reach unacceptable values: the first passage time. A related question pertains to the statistical distributions of the extreme values of these variables in a given period of time. The authors discuss some problems drawn from population ecology and environmental engineering to illustrate the usefulness of the first passage time concept

  18. A Bolus Calculator Based on Continuous-Discrete Unscented Kalman Filtering for Type 1 Diabetics

    DEFF Research Database (Denmark)

    Boiroux, Dimitri; Aradóttir, Tinna Björk; Hagdrup, Morten

    2015-01-01

    both reduces the risk of hypoglycemia in case of an overestimated meal and the time spent in hyperglycemia if the meal size is underestimated. Faster insulin and the use of glucagon will have the potential to encourage postprandial meal bolus administration and hence will not require to accurately......In patients with type 1 diabetes, the effects of meals intake on blood glucose level are usually mitigated by administering a large amount of insulin (bolus) at mealtime or even slightly before. This strategy assumes, among other things, a prior knowledge of the meal size and the postprandial...... glucose dynamics. On the other hand, administering the meal bolus during or after mealtime could benefit from the information provided by the postprandial meal dynamics at the expense of a delayed meal bolus. The present paper investigates different bolus administration strategies (at mealtime, 15 minutes...

  19. An Adaptive Nonlinear Basal-Bolus Calculator for Patients With Type 1 Diabetes

    DEFF Research Database (Denmark)

    Boiroux, Dimitri; Aradóttir, Tinna Björk; Nørgaard, Kirsten

    2017-01-01

    size. Following meal announcements, the meal compartment and the meal time constant are estimated, otherwise insulin sensitivity is estimated. Results : We compare the performance of a conventional linear bolus calculator with the proposed bolus calculator. The proposed basal-bolus calculator......Background : Bolus calculators help patients with type 1 diabetes to mitigate the effect of meals on their blood glucose by administering a large amount of insulin at mealtime. Intraindividual changes in patients physiology and nonlinearity in insulin-glucose dynamics pose a challenge...... glucose monitor (CGM). The basal rate is determined by calculating the steady state of the model and is adjusted once a day before breakfast. The bolus size is determined by optimizing the postprandial glucose values based on an estimate of the insulin sensitivity and states, as well as the announced meal...

  20. The passage of a diffusible indicator through a microvascular system

    Directory of Open Access Journals (Sweden)

    Kislukhin Victor V

    2013-02-01

    Full Text Available Abstract The aim. (1 To develop a mathematical model of the passage of a diffusible indicator through microcirculation based on a stochastic description of diffusion and flow; (2 To use Goresky transform of the dilution curves of the diffusible indicators for the estimation of the permeability of a tissue-capillary barrier. The method. We assume that there are two causes for flow to be stochastic: (a All microvessels are divided between open and closed microvessels. There exists random exchange between the two groups. (b The flow through open microvessels is also random. We assume that each diffusing tracer has a probability to leave the intravascular space, and has a probability to return. We also assume that all considered processes are stationary (stability of microcirculation. Conclusion. (a The distribution of the time to pass microcirculation by diffusing indicator is given by a compound Poisson distribution; (b The permeability of tissue-capillary barrier can be obtained from the means, delay, and dispersions of the dilutions of intravascular and diffusing traces.

  1. Tracer transport in fractured rocks

    International Nuclear Information System (INIS)

    Tsang, C.F.; Tsang, Y.W.; Hale, F.V.

    1988-07-01

    Recent interest in the safety of toxic waste underground disposal and nuclear waste geologic repositories has motivated many studies of tracer transport in fractured media. Fractures occur in most geologic formations and introduce a high degree of heterogeneity. Within each fracture, the aperture is not constant in value but strongly varying. Thus for such media, tracer tends to flow through preferred flowpaths or channels within the fractures. Along each of these channels, the aperture is also strongly varying. A detailed analysis is carried out on a 2D single fracture with variable apertures and the flow through channels is demonstrated. The channels defined this way are not rigidly set pathways for tracer transport, but are the preferred flow paths in the sense of stream-tubes in the potential theory. It is shown that such variable-aperture channels can be characterized by an aperture probability distribution function, and not by the exact deterministic geometric locations. We also demonstrate that the 2D tracer transport in a fracture can be calculated by a model of a system of 1D channels characterized by this distribution function only. Due to the channeling character of tracer transport in fractured rock, random point measurements of tracer breakthrough curves may give results with a wide spread in value due to statistical fluctuations. The present paper suggests that such a wide spread can probably be greatly reduced by making line/areal (or multiple) measurements covering a few spatial correlation lengths. 13 refs., 11 figs., 1 tab

  2. Limites, passages et transformations en jeu dans l’architecture / Limits, passages and transformations involved in Architecture.

    Directory of Open Access Journals (Sweden)

    Younès, Chris

    2006-11-01

    Full Text Available La manière de tracer des limites et d’opérer des passages par transferts, incursions, interférences notamment, rend compte du mode d’expression propre à l’architecture et de sa façon d’agencer le stable et l’instable, le délimité et l’illimité, la mesure et l’incommensurable, la continuité et la discontinuité. L’art de les mettre en œuvre par le projet architectural, urbain et paysager est une des problématiques de recherche du laboratoire interdisciplinaire Gerjau (philosophie architecture urbain qui a conduit différentes études sur ce sujet et en particulier du point de vue des rapports entre nature et culture./The way in which limits are drawn and passageways are operated for transfers, incursions, and specially interferences, show how architecture has it’s own way of expression that deals with the stable and the unstable, the limited and the unlimited, etc.

  3. Modeling the retention of rumen boluses for the electronic identification of goats.

    Science.gov (United States)

    Carné, S; Caja, G; Ghirardi, J J; Salama, A A K

    2011-02-01

    We constructed a regression model to estimate the retention of electronic boluses in goats. With this aim, 2,482 boluses were administered to goats from dairy (Murciano-Granadina, n=1,326; French Alpine, n=381) and meat (Blanca de Rasquera, n=532) breeds. A total of 19 bolus types made of materials (ceramic, plastic tubes filled with concrete or silicone, and ballasts) differing in their specific gravity (SG) were used, thereby obtaining a wide variation in bolus features: diameter (9 to 22 mm), length (37 to 84 mm), weight (5 to 111 g), volume (2.6 to 26 mL), and SG (1.0 to 5.5). Each bolus contained a half-duplex glass encapsulated transponder (32 × 3.8mm) and was administered using adapted balling guns. Murciano-Granadina and Blanca de Rasquera goats also wore 2 visual plastic ear tags: V1 (double flag, 5.1g) and V2 (flag-button, 4.2g). No data on ear tags in French Alpine goats was available. Bolus and ear tag retention [(retained/monitored) × 100] was recorded for at least 1 yr. Dynamic reading efficiency [(dynamic reading/static reading) × 100] was also evaluated from 1,496 bolus readings. No administration incidences or apparent negative behavior or performance effects were observed for any bolus type. Static reading efficiency of retained boluses was 100%, except for the prototypes with metal ballasts, which yielded a 93.3% reading efficiency. Retention of metal-ballasted boluses was confirmed using x-ray equipment. Excluding ballasted boluses, a 99.5% dynamic reading efficiency was obtained. Ear tag losses were 6.5% for V1 and 3.7% for V2, ranging from 3.2 to 7.8% depending on ear tag type and goat breed. Bolus retention varied (0 to 100%) according to their physical features. Obtained data allowed the fitting of a logistic model of bolus retention rate according to bolus volume and weight (R(2) = 0.98); the SG was implicitly considered. Estimated weight and SG to produce medium- (15 mL) and standard-sized (22 mL) boluses for 99.95% retention rate in

  4. The comparison of bolus tracking and test bolus techniques for computed tomography thoracic angiography in healthy beagles

    Directory of Open Access Journals (Sweden)

    Nicolette Cassel

    2013-05-01

    Full Text Available Computed tomography thoracic angiography studies were performed on five adult beagles using the bolus tracking (BT technique and the test bolus (TB technique, which were performed at least two weeks apart. For the BT technique, 2 mL/kg of 300 mgI/mL iodinated contrast agent was injected intravenously. Scans were initiated when the contrast in the aorta reached 150 Hounsfield units (HU. For the TB technique, the dogs received a test dose of 15% of 2 mL/kg of 300 mgI/mL iodinated contrast agent, followed by a series of low dose sequential scans. The full dose of the contrast agent was then administered and the scans were conducted at optimal times as identified from time attenuation curves. Mean attenuation in HU was measured in the aorta (Ao and right caudal pulmonary artery (rCPA. Additional observations included the study duration, milliAmpere (mA, computed tomography dose index volume (CTDI[vol] and dose length product (DLP. The attenuation in the Ao (BT = 660 52 HU ± 138 49 HU, TB = 469 82 HU ± 199 52 HU, p = 0.13 and in the rCPA (BT = 606 34 HU ± 143 37 HU, TB = 413 72 HU ± 174.99 HU, p = 0.28 did not differ significantly between the two techniques. The BT technique was conducted in a significantly shorter time period than the TB technique (p = 0.03. The mean mA for the BT technique was significantly lower than the TB technique (p = 0.03, as was the mean CTDI(vol (p = 0.001. The mean DLP did not differ significantly between the two techniques (p = 0.17. No preference was given to either technique when evaluating the Ao or rCPA but the BT technique was shown to be shorter in duration and resulted in less DLP than the TB technique.

  5. RITES OF PASSAGE AND SUSTANABLE DEVELOPMENT IN ...

    African Journals Online (AJOL)

    throughout the world experience and perform rites of passage in their different cultures ... The various stages of human development starting from birth, puberty ... one is momentary stripped of former self and status and recreate to something new ... culture of African and X-ray their attachment to their gods and supernatural ...

  6. Yakima Basin Fish Passage Project, Phase 2

    International Nuclear Information System (INIS)

    1991-08-01

    Implementation of the Yakima Basin Fish Passage Project -- Phase 2 would significantly improve the production of anadromous fish in the Yakima River system. The project would provide offsite mitigation and help to compensate for lower Columbia River hydroelectric fishery losses. The Phase 2 screens would allow greater numbers of juvenile anadromous fish to survive. As a consequence, there would be higher returns of adult salmon and steelhead to the Yakima River. The proposed action would play an integral part in the overall Yakima River anadromous fish enhancement program (fish passage improvement, habitat enhancement, hatchery production increases, and harvest management). These would be environmental benefits associated with implementation of the Fish Passage and Protective Facilities Phase 2 Project. Based on the evaluation presented in this assessment, there would be no significant adverse environmental impacts if the proposed action was carried forward. No significant adverse environmental effects have been identified from construction and operation of the Yakima Phase 2 fish passage project. Proper design and implementation of the project will ensure no adverse effects will occur. Based on the information in this environmental analysis, BPA's and Reclamation's proposal to construct these facilities does not constitute a major Federal action that could significantly affect the quality of the human environment. 8 refs., 4 figs., 6 tabs

  7. Navigable windows of the Northwest Passage

    Science.gov (United States)

    Liu, Xing-he; Ma, Long; Wang, Jia-yue; Wang, Ye; Wang, Li-na

    2017-09-01

    Artic sea ice loss trends support a greater potential for Arctic shipping. The information of sea ice conditions is important for utilizing Arctic passages. Based on the shipping routes given by ;Arctic Marine Shipping Assessment 2009 Report;, the navigable windows of these routes and the constituent legs were calculated by using sea ice concentration product data from 2006 to 2015, by which a comprehensive knowledge of the sea ice condition of the Northwest Passage was achieved. The results showed that Route 4 (Lancaster Sound - Barrow Strait - Prince Regent Inlet and Bellot Strait - Franklin Strait - Larsen Sound - Victoria Strait - Queen Maud Gulf - Dease Strait - Coronation Gulf - Dolphin and Union Strait - Amundsen Gulf) had the best navigable expectation, Route 2 (Parry Channel - M'Clure Strait) had the worst, and the critical legs affecting the navigation of Northwest Passage were Viscount Melville Sound, Franklin Strait, Victoria Strait, Bellot Strait, M'Clure Strait and Prince of Wales Strait. The shortest navigable period of the routes of Northwest Passage was up to 69 days. The methods used and the results of the study can help the selection and evaluation of Arctic commercial routes.

  8. Intravenous Tranexamic Acid Bolus plus Infusion Is Not More Effective than a Single Bolus in Primary Hip Arthroplasty: A Randomized Controlled Trial.

    Science.gov (United States)

    Zufferey, Paul J; Lanoiselée, Julien; Chapelle, Céline; Borisov, Dmitry B; Bien, Jean-Yves; Lambert, Pierre; Philippot, Rémi; Molliex, Serge; Delavenne, Xavier

    2017-09-01

    Preoperative administration of the antifibrinolytic agent tranexamic acid reduces bleeding in patients undergoing hip arthroplasty. Increased fibrinolytic activity is maintained throughout the first day postoperation. The objective of the study was to determine whether additional perioperative administration of tranexamic acid would further reduce blood loss. This prospective, double-blind, parallel-arm, randomized, superiority study was conducted in 168 patients undergoing unilateral primary hip arthroplasty. Patients received a preoperative intravenous bolus of 1 g of tranexamic acid followed by a continuous infusion of either tranexamic acid 1 g (bolus-plus-infusion group) or placebo (bolus group) for 8 h. The primary outcome was calculated perioperative blood loss up to day 5. Erythrocyte transfusion was implemented according to a restrictive transfusion trigger strategy. The mean perioperative blood loss was 919 ± 338 ml in the bolus-plus-infusion group (84 patients analyzed) and 888 ± 366 ml in the bolus group (83 patients analyzed); mean difference, 30 ml (95% CI, -77 to 137; P = 0.58). Within 6 weeks postsurgery, three patients in each group (3.6%) underwent erythrocyte transfusion and two patients in the bolus group experienced distal deep-vein thrombosis. A meta-analysis combining data from this study with those of five other trials showed no incremental efficacy of additional perioperative administration of tranexamic acid. A preoperative bolus of tranexamic acid, associated with a restrictive transfusion trigger strategy, resulted in low erythrocyte transfusion rates in patients undergoing hip arthroplasty. Supplementary perioperative administration of tranexamic acid did not achieve any further reduction in blood loss.

  9. Fluorescence tracers as a reference for pesticide transport in wetland systems

    Science.gov (United States)

    Lange, Jens; Passeport, Elodie; Tournebize, Julien

    2010-05-01

    Two different fluorescent tracers, Uranine (UR) and Sulforhodamine (SRB), were injected as a pulse into surface flow wetlands. Tracer breakthrough curves were used to document hydraulic efficiencies, peak attenuation and retention capacities of completely different wetland systems. The tracers were used as a reference to mimic photolytic decay (UR) and sorption (SRB) of contaminants, since a real herbicide (Isoproturon, IPU) was injected in parallel to UR and SRB. Analysis costs limited IPU sampling frequency and single samples deviated from the tracer breakthrough curves. Still, a parallel behavior of IPU and SRB could be observed in totally different wetland systems, including underground passage through drainage lines. Similar recovery rates for IPU and SRB confirmed this observation. Hence, SRB was found to be an appropriate reference tracer to mimic the behavior of mobile pesticides (low KOC, without degradation) in wetland systems and the obtained wetland characteristics for SRB may serve as an indication for contaminant retention. Owing to the properties of IPU, the obtained results should be treated as worst case scenarios for highly mobile pesticides. A comparison of six different wetland types suggested that non-steady wetland systems with large variation in water level may temporally store relatively large amounts of tracers (contaminants), partly in areas that are not continuously saturated. This may lead to an efficient attenuation of peak concentrations. However, when large parts of these systems are flushed by natural storm events, tracers (contaminants) may be re-mobilized. In steady systems vegetation density and water depth were found to be the most important factors for tracer/contaminant retention. Illustrated by SRB, sorption on sediments and vegetation was a quick, almost instantaneous process which lead to considerable tracer losses even at high flow velocities and short contact times. Shallow systems with dense vegetation appeared to be the

  10. Measurement of open streams by using tracers

    International Nuclear Information System (INIS)

    Ramos, German F.; Tarquino, W.; Curcuy, H.; Orozco, C.

    1999-01-01

    This paper presents an intercomparison study to be carried out between flux measurements by using tracers and moulinet. This intercomparison is scheduled to be performed at the measurement station belonging to the National Service of Meteorology and Hydrology (SENAMHI). Two techniques of tracer dilution are outstanded: total evaluation with tracer punctual injection and punctual evaluation with tracer continuous injection. Total evaluation with tracer punctual injection has been used since this technique is considered to be more suitable for hydrology purposes

  11. The use of Coca-Cola in the management of bolus obstruction in benign oesophageal stricture.

    Science.gov (United States)

    Karanjia, N. D.; Rees, M.

    1993-01-01

    Oesophageal stricture is a complication of oesophageal reflux and may itself be complicated by bolus obstruction. We reviewed the records of patients presenting with dysphagia and who were found to have benign oesophageal strictures. We studied the outcome of bolus obstruction in 13 episodes affecting eight patients. In six episodes Coca-Cola was administered on the day before endoscopy, and in all these patients the bolus had cleared. In seven episodes nothing was administered before endoscopy, and in all seven a bolus was evident at endoscopy. In five of these seven the bolus was removed piecemeal and in each of these instances the endoscope had to be passed between two and five times. In the remaining two instances the procedure was abandoned and the patients returned to the ward for the administration of Coca-Cola. At subsequent endoscopy these patients were found to be clear of any bolus. These results suggest that the administration of Coca-Cola (or other aerated drinks) may clear a bolus in the acutely obstructed oesophagus. PMID:8476194

  12. The usefulness of esophagogram with marchmallow bolus in patients with esophageal related symptoms

    International Nuclear Information System (INIS)

    Yoon, Sang Wook; Kim, Ki Whang; Park, Hyo Jin; Kim, Eun Kyung; Yu, Jeong Sik; Seo, Jung Kun; Kwon, Ryang; Shin, Hyung Cheol

    1996-01-01

    To evaluate the usefulness of the esophagogram using marshmallow bolus in the evaluation of the causes of variable esophageal-related symptoms. Esophagograms using marshmallow bolus were performed on 44 patients with esophageal-related symptoms and on ten normal volunteers. Videofluoroscopic studies were also made. Patients were classified into three groups according to their esophageal-related symptoms ; those with dysphagia, those with globus symptom, and those with chest pain. Abnormal findings on an esophagogram with marshmallow were graded in to three categories ; mild, moderate, and severe. Provocation of the same symptom was also evaluated. Esophageal monometric studies were performed on 16 patients and those results were compared with the results obtained from the esophagogram using marshmallow bolus. The provocation rate of the some symptom was 33% in the first group, 47% in the second, and 24% in the third. The provocation rate was highest in the second group. The provocation rate was also higher in patients with a severe degree of abnormality on an esophagogram using marshmallow bolus. Where there were abnormal findings, an esophagogram using marshmallow bolus showed a higher abnormality rate than did a conventional esophagogram. In cases showing abnormal finding son the esophageal monometric study, an esophagogram using marshmallow bolus showed a higher provocation rate and more severe abnormality than in cases showing normal findings on manometric study. An esophagogram using marshmallow bolus will a useful radiologic screening modality for the evaluation of patients with esophageal-related symptoms

  13. The usefulness of esophagogram with marchmallow bolus in patients with esophageal related symptoms

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Sang Wook; Kim, Ki Whang; Park, Hyo Jin; Kim, Eun Kyung; Yu, Jeong Sik; Seo, Jung Kun; Kwon, Ryang; Shin, Hyung Cheol [Yonsei Univ. College of Medicine, Seoul (Korea, Republic of)

    1996-03-01

    To evaluate the usefulness of the esophagogram using marshmallow bolus in the evaluation of the causes of variable esophageal-related symptoms. Esophagograms using marshmallow bolus were performed on 44 patients with esophageal-related symptoms and on ten normal volunteers. Videofluoroscopic studies were also made. Patients were classified into three groups according to their esophageal-related symptoms ; those with dysphagia, those with globus symptom, and those with chest pain. Abnormal findings on an esophagogram with marshmallow were graded in to three categories ; mild, moderate, and severe. Provocation of the same symptom was also evaluated. Esophageal monometric studies were performed on 16 patients and those results were compared with the results obtained from the esophagogram using marshmallow bolus. The provocation rate of the some symptom was 33% in the first group, 47% in the second, and 24% in the third. The provocation rate was highest in the second group. The provocation rate was also higher in patients with a severe degree of abnormality on an esophagogram using marshmallow bolus. Where there were abnormal findings, an esophagogram using marshmallow bolus showed a higher abnormality rate than did a conventional esophagogram. In cases showing abnormal finding son the esophageal monometric study, an esophagogram using marshmallow bolus showed a higher provocation rate and more severe abnormality than in cases showing normal findings on manometric study. An esophagogram using marshmallow bolus will a useful radiologic screening modality for the evaluation of patients with esophageal-related symptoms.

  14. Nonlinear pharmacokinetics of visnagin in rats after intravenous bolus administration.

    Science.gov (United States)

    Haug, Karin G; Weber, Benjamin; Hochhaus, Guenther; Butterweck, Veronika

    2012-01-23

    Ammi visnaga L. (syn. Khella, Apiaceae) preparations have traditionally been used in the Middle East for the treatment of kidney stone disease. Visnagin, a furanocoumarin derivative, is one of the main compounds of Ammi visnaga with potential effects on kidney stone prevention. To date, no information is available about the pharmacokinetic (PK) properties of visnagin. It was the aim of the study to characterize the PK properties of visnagin after intravenous (i.v.) bolus administration in rats and to develop an adequate model for the description of the observed data, including model parameter estimates. Therefore, three doses of visnagin (1.25, 2.5, and 5mg/kg) solubilized in 25% Captisol® were administered by i.v. bolus injection to male Sprague-Dawley rats. Plasma samples were extracted and subsequently analyzed using a validated LC-MS/MS method. Both non-compartmental and compartmental PK analyses were performed. A stepwise model building approach was applied including nonlinear mixed effect modeling for final model selection and to obtain final model estimates in NONMEM VI. The average areas under the curve (AUC(0-last)) after doses of 1.25, 2.5, and 5mg/kg were 1.03, 3.61, and 12.6 mg *h/l, respectively. The shape of the plasma concentration-time profiles and the observed disproportionate increase in AUC(0-last) with increasing dose suggested nonlinearity in the elimination of visnagin. A two-compartment Michaelis-Menten model provided the best fit with following typical values of the parameter estimates: 2.09 mg/(l*h) (V(max)), 0.08 mg/l (K(M)), 0.175 l (V(C)), 1.0 h⁻¹ (k₁₂), and 1.22 h⁻¹ (k₂₁). Associated inter-subject variability estimates (% CV) for V(max), K(M) and V(C) were 21.8, 70.9, and 9.2, respectively. Intra-subject variability (constant CV error model) was estimated to be 7.0%. The results suggest the involvement of a saturable process in the elimination of visnagin, possibly an enzyme or transporter system. Copyright © 2011

  15. SU-F-T-517: Determining the Tissue Equivalence of a Brass Mesh Bolus in a Reconstructed Chest Wall Irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Shekel, E; Epstein, D; Levin, D [Dept of radiotherapy, Assuta Medical Centers, Tel Aviv (Israel)

    2016-06-15

    Purpose: To determine the tissue equivalence of a brass mesh bolus (RPD) in the setting of a reconstructed chest wall irradiation Methods: We measured breast skin dose delivered by a tangential field plan on an anthropomorphic phantom using Mosfet and nanoDot (Landauer) dosimeters in five different locations on the breast. We also measured skin dose using no bolus, 5mm and 10 mm superflab bolus. In the Eclipse treatment planning system (Varian, Palo Alto, CA) we calculated skin dose for different bolus thicknesses, ranging from 0 to 10 mm, in order to evaluate which calculation best matches the brass mesh measurements, as the brass mesh cannot be simulated due to artefacts.Finally, we measured depth dose behavior with the brass mesh bolus to verify that the bolus does not affect the dose to the breast itself beyond the build-up region. Results: Mosfet and nanoDot measurements were consistent with each other.As expected, skin dose measurements with no bolus had the least agreement with Eclipse calculation, while measurements for 5 and 10 mm agreed well with the calculation despite the difficulty in conforming superflab bolus to the breast contour. For the brass mesh the best agreement was for 3 mm bolus Eclipse calculation. For Mosfets, the average measurement was 90.8% of the expected dose, and for nanoDots 88.33% compared to 83.34%, 88.64% and 93.94% (2,3 and 5 mm bolus calculation respectively).The brass mesh bolus increased skin dose by approximately 25% but there was no dose increase beyond the build-up region. Conclusion: Brass mesh bolus is most equivalent to a 3 mm bolus, and does not affect the dose beyond the build-up region. The brass mesh cannot be directly calculated in Eclipse, hence a 3mm bolus calculation is a good reflection of the dose response to the brass mesh bolus.

  16. Radioactive tracers in the sea

    International Nuclear Information System (INIS)

    Jenkins, W.J.; Livingston, H.D.

    1980-01-01

    Artificial radionuclides introduced to the oceans during the last four decades have proved invaluable tools for study of many processes in marine water columns and sediments. Both global and close-in fallout of radioactivity from atmospheric nuclear weapons testing have distributed these radionuclides widely, and in amounts sufficient to be useful as tracers. An additional source of considerable significance and tracer potential comes from coastal discharges of European nuclear fuel reprocessing wastes. The nature of these sources, types and amounts of radionuclides introduced and the time histories of their introduction generate a variety of tracer distributions which illuminate a broad spectrum of physical and chemical processes active over a wide range of timescales. Depending on their respective chemistries, artificial radionuclides have been demonstrated to exhibit both conservative and non-conservative properties in the oceans. Some examples are given of the uses made of soluble, conservative tracers for the study of oceanic transport processes and of non-conservative tracers for studies of processes which move them to, and mix them within, marine sediments. Sampling and measurement techniques which have been used in these studies are described

  17. Efficacy study of Styplon Vet Bolus as supportive therapy in management of hemorrhagic conditions of ruminants

    Directory of Open Access Journals (Sweden)

    B R Ravikumar

    Full Text Available On-field trial was conducted in dairy animals to evaluate efficacy of Styplon Vet Bolus (M/s Himalaya Drug Company, Banglore, India as supportive therapy in management of hemorrhagic conditions (Hematuria, hemoagalectia, bleeding wounds, uterine bleeding and epistaxis of ruminants. Styplon Vet 1-2 boli twice daily was administered to cows and buffaloes, and ½ bolus twice daily for sheep till they recover clinically. The results indicated that Styplon Vet Bolus is a safe and effective styptic in ruminants. [Vet World 2009; 2(12.000: 470-471

  18. Comparison of first pass bolus AIFs extracted from sequential 18F-FDG PET and DSC-MRI of mice

    International Nuclear Information System (INIS)

    Evans, Eleanor; Sawiak, Stephen J.; Ward, Alexander O.; Buonincontri, Guido; Hawkes, Robert C.; Adrian Carpenter, T.

    2014-01-01

    Accurate kinetic modelling of in vivo physiological function using positron emission tomography (PET) requires determination of the tracer time–activity curve in plasma, known as the arterial input function (AIF). The AIF is usually determined by invasive blood sampling methods, which are prohibitive in murine studies due to low total blood volumes. Extracting AIFs from PET images is also challenging due to large partial volume effects (PVE). We hypothesise that in combined PET with magnetic resonance imaging (PET/MR), a co-injected bolus of MR contrast agent and PET ligand can be tracked using fast MR acquisitions. This protocol would allow extraction of a MR AIF from MR contrast agent concentration–time curves, at higher spatial and temporal resolution than an image-derived PET AIF. A conversion factor could then be applied to the MR AIF for use in PET kinetic analysis. This work has compared AIFs obtained from sequential DSC-MRI and PET with separate injections of gadolinium contrast agent and 18 F-FDG respectively to ascertain the technique′s validity. An automated voxel selection algorithm was employed to improve MR AIF reproducibility. We found that MR and PET AIFs displayed similar character in the first pass, confirmed by gamma variate fits (p<0.02). MR AIFs displayed reduced PVE compared to PET AIFs, indicating their potential use in PET/MR studies

  19. Radiochemical tracers in marine biology

    International Nuclear Information System (INIS)

    Petrocelli, S.R.; Anderson, J.W.; Neff, J.M.

    1977-01-01

    Tracers have been used in a great variety of experimentation. More recently, labeled materials have been applied in marine biological research. Some of the existing tracer techniques have been utilized directly, while others have been modified to suit the specific needs of marine biologists. This chapter describes some of the uses of tracers in marine biological research. It also mentions the problems encountered as well as offering possible solutions and discusses further applications of these techniques. Only pertinent references are cited and additional information may be obtained by consulting these references. Due to their relative ease of maintenance, freshwater species are also utilized in studies which involve radiotracer techniques. Since most of these techniques e directly applicable to marine species, some of these studies will also be included

  20. Radioisotope tracer applications in industry

    International Nuclear Information System (INIS)

    Rao, S.M.

    1987-01-01

    Radioisotope tracers have many advantages in industrial trouble-shooting and studies on process kinetics. The applications are mainly of two types: one leading to qualitative (Yes or No type) information and the other to quantitative characterisation of flow processes through mass balance considerations and flow models. ''Yes or No'' type methods are mainly used for leakage and blockage locations in pipelines and in other industrial systems and also for location of water seepage zones in oil wells. Flow measurements in pipelines and mercury inventory in electrolytic cells are good examples of tracer methods using the mass balance approach. Axial dispersion model and Tanks-in-Series model are the two basic flow models commonly used with tracer methods for the characterisation of kinetic processes. Examples include studies on flow processes in sugar crystallisers as well as in a precalcinator in a cement plant. (author). 18 figs

  1. Trapped Ion Quantum Computation by Adiabatic Passage

    International Nuclear Information System (INIS)

    Feng Xuni; Wu Chunfeng; Lai, C. H.; Oh, C. H.

    2008-01-01

    We propose a new universal quantum computation scheme for trapped ions in thermal motion via the technique of adiabatic passage, which incorporates the advantages of both the adiabatic passage and the model of trapped ions in thermal motion. Our scheme is immune from the decoherence due to spontaneous emission from excited states as the system in our scheme evolves along a dark state. In our scheme the vibrational degrees of freedom are not required to be cooled to their ground states because they are only virtually excited. It is shown that the fidelity of the resultant gate operation is still high even when the magnitude of the effective Rabi frequency moderately deviates from the desired value.

  2. Serum levels of bupivacaine after pre-peritoneal bolus vs. epidural bolus injection for analgesia in abdominal surgery: A safety study within a randomized controlled trial.

    Science.gov (United States)

    Mungroop, Timothy H; van Samkar, Ganapathy; Geerts, Bart F; van Dieren, Susan; Besselink, Marc G; Veelo, Denise P; Lirk, Philipp

    2017-01-01

    Continuous wound infiltration (CWI) has become increasingly popular in recent years as an alternative to epidural analgesia. As catheters are not placed until the end of surgery, more intraoperative opioid analgesics might be needed. We, therefore, added a single pre-peritoneal bolus of bupivacaine at the start of laparotomy, similar to the bolus given with epidural analgesia. This was a comparative study within a randomized controlled trial (NTR4948). Patients undergoing hepato-pancreato-biliary surgery received either a pre-peritoneal bolus of 30ml bupivacaine 0.25%, or an epidural bolus of 10ml bupivacaine 0.25% at the start of laparotomy. In a subgroup of patients, we sampled blood and determined bupivacaine serum levels 20, 40, 60 and 80 minutes after bolus injection. We assumed toxicity of bupivacaine to be >1000 ng/ml. A total of 20 patients participated in this sub-study. All plasma levels measured as well as the upper limit of the predicted 99% confidence intervals per time point were well below the toxicity limit. In a mixed linear-effect model both groups did not differ statistically significant (p = 0.131). The intra-operative use of opioids was higher with CWI as compared to epidural (86 (SD 73) μg sufentanil vs. 50 (SD 32). In this exploratory study, the pre-peritoneal bolus using bupivacaine resulted in serum bupivacaine concentrations well below the commonly accepted toxic threshold. With CWI more additional analgesics are needed intraoperatively as compared to epidural analgesia, although this is compensated by a reduction in use of vasopressors with CWI. Netherlands Trial Register NTR4948.

  3. 21 CFR 520.1802b - Piperazine-carbon disulfide complex boluses.

    Science.gov (United States)

    2010-04-01

    ...) per 500 pounds body weight; removal of large strongyles, pinworms, and bots, 1 bolus per 250 pounds...), large strongyles (Strongylus spp.) bots (Gastrophilus spp.), small strongyles, and pinworms (Oxyuris...

  4. Assessment of myocardial perfusion with MRI using a modified dual bolus method

    International Nuclear Information System (INIS)

    Husso, M; Sipola, P; Manninen, H; Vainio, P; Kuittinen, T; Hartikainen, J; Saarakkala, S; Töyräs, J; Kuikka, J

    2014-01-01

    Quantification of regional myocardial blood flow (rMBF) with first-pass magnetic resonance imaging (FP-MRI) requires two contrast agent injections (dual bolus technique), inducing error in the determined rMBF if the injections differ. We hypothesize that using input and residue curves of the same injection would be more reliable. We aim to introduce and evaluate a novel method to correct the high concentration arterial input function (AIF) for determination of rMBF. Sixteen patients with non-Hodgkin's lymphoma were examined before and after chemotherapy. The input function was solved by correcting initial high concentration AIF using the ratio of low and high contrast AIF areas, normalized by corresponding heart rates (modified dual bolus method). For comparison, the scaled low contrast AIF was used as an input function (dual bolus method). Unidirectional transfer coefficient K trans  was calculated using both methods. K trans -values determined with the dual bolus (0.81 ± 0.32 ml g −1  min −1 ) and modified dual bolus (0.77 ± 0.42 ml g −1  min −1 ) methods were in agreement (p = 0.21). Mean K trans -values increased from 0.76 ± 0.43 to 0.89 ± 0.55 ml g −1  min −1  after chemotherapy (p = 0.17). The modified dual bolus technique agrees with the dual bolus technique (R2 = 0.899) when the low and high contrast injections are similar. However, when this is not the case, the modified dual bolus technique may be more reliable. (paper)

  5. The Interactive Effect of Diabetes Family Conflict and Depression on Insulin Bolusing Behaviors for Youth.

    Science.gov (United States)

    Maliszewski, Genevieve; Patton, Susana R; Midyett, L Kurt; Clements, Mark A

    2017-05-01

    Adherence to type 1 diabetes management declines as children enter adolescence. For youth, psychosocial variables including mood and interpersonal relationships play a large role in diabetes maintenance. The current study assessed the unique and interactive roles diabetes family conflict and depression have on insulin bolusing behaviors for youth ages 10-16 years. Ninety-one youth-parent dyads completed a survey assessing family conflict and depression. Mean daily blood glucose levels, mealtime insulin bolus scores ( BOLUS), and glycated hemoglobin (HbA1c) were collected from the medical record as outcome variables. Parent-reported diabetes-related family conflict and youths' endorsed depression both significantly predicted insulin bolusing behavior, R 2 = .13, F(2, 88) = 6.66, P family conflict and youth depression played a significant role in youths' bolusing behaviors, above and beyond that which was predicted by conflict and depression separately, R 2 = .18, F change (1, 87) = 4.63, P family conflict, while there was no change in BOLUS scores among depressed youth living in families reporting less conflict. Findings underscore the importance of screening for depression and family conflict in youth experiencing or at risk for poor adherence to mealtime insulin and higher HbA1c levels.

  6. Tracers of cancer cells in nuclear oncology

    International Nuclear Information System (INIS)

    Tamgac, F.; Baillet, G.; Moretti, J.L.; Safi, N.; Weinmann, P.; Beco, V. de

    1997-01-01

    Evaluating the extent of disease is important in planning cancer treatment. Different types of tracers are used in vivo to diagnose tumors and these tracers can give supplementary information on the differentiation degree of tumors and response to therapy. (authors)

  7. Serum levels of bupivacaine after pre-peritoneal bolus vs. epidural bolus injection for analgesia in abdominal surgery: A safety study within a randomized controlled trial

    NARCIS (Netherlands)

    Mungroop, Timothy H.; van Samkar, Ganapathy; Geerts, Bart F.; van Dieren, Susan; Besselink, Marc G.; Veelo, Denise P.; Lirk, Philipp

    2017-01-01

    Continuous wound infiltration (CWI) has become increasingly popular in recent years as an alternative to epidural analgesia. As catheters are not placed until the end of surgery, more intraoperative opioid analgesics might be needed. We, therefore, added a single pre-peritoneal bolus of bupivacaine

  8. A Patient-Specific Polylactic Acid Bolus Made by a 3D Printer for Breast Cancer Radiation Therapy.

    Directory of Open Access Journals (Sweden)

    So-Yeon Park

    Full Text Available The aim of this study was to assess the feasibility and advantages of a patient-specific breast bolus made using a 3D printer technique.We used the anthropomorphic female phantom with breast attachments, which volumes are 200, 300, 400, 500 and 650 cc. We simulated the treatment for a right breast patient using parallel opposed tangential fields. Treatment plans were used to investigate the effect of unwanted air gaps under bolus on the dose distribution of the whole breast. The commercial Super-Flex bolus and 3D-printed polylactic acid (PLA bolus were applied to investigate the skin dose of the breast with the MOSFET measurement. Two boluses of 3 and 5 mm thicknesses were selected.There was a good agreement between the dose distribution for a virtual bolus generated by the TPS and PLA bolus. The difference in dose distribution between the virtual bolus and Super-Flex bolus was significant within the bolus and breast due to unwanted air gaps. The average differences between calculated and measured doses in a 200 and 300 cc with PLA bolus were not significant, which were -0.7% and -0.6% for 3mm, and -1.1% and -1.1% for 5 mm, respectively. With the Super-Flex bolus, however, significant dose differences were observed (-5.1% and -3.2% for 3mm, and -6.3% and -4.2% for 5 mm.The 3D-printed solid bolus can reduce the uncertainty of the daily setup and help to overcome the dose discrepancy by unwanted air gaps in the breast cancer radiation therapy.

  9. A Patient-Specific Polylactic Acid Bolus Made by a 3D Printer for Breast Cancer Radiation Therapy.

    Science.gov (United States)

    Park, So-Yeon; Choi, Chang Heon; Park, Jong Min; Chun, MinSoo; Han, Ji Hye; Kim, Jung-In

    2016-01-01

    The aim of this study was to assess the feasibility and advantages of a patient-specific breast bolus made using a 3D printer technique. We used the anthropomorphic female phantom with breast attachments, which volumes are 200, 300, 400, 500 and 650 cc. We simulated the treatment for a right breast patient using parallel opposed tangential fields. Treatment plans were used to investigate the effect of unwanted air gaps under bolus on the dose distribution of the whole breast. The commercial Super-Flex bolus and 3D-printed polylactic acid (PLA) bolus were applied to investigate the skin dose of the breast with the MOSFET measurement. Two boluses of 3 and 5 mm thicknesses were selected. There was a good agreement between the dose distribution for a virtual bolus generated by the TPS and PLA bolus. The difference in dose distribution between the virtual bolus and Super-Flex bolus was significant within the bolus and breast due to unwanted air gaps. The average differences between calculated and measured doses in a 200 and 300 cc with PLA bolus were not significant, which were -0.7% and -0.6% for 3mm, and -1.1% and -1.1% for 5 mm, respectively. With the Super-Flex bolus, however, significant dose differences were observed (-5.1% and -3.2% for 3mm, and -6.3% and -4.2% for 5 mm). The 3D-printed solid bolus can reduce the uncertainty of the daily setup and help to overcome the dose discrepancy by unwanted air gaps in the breast cancer radiation therapy.

  10. A Study on the Necessary Number of Bolus Treatments in Radiotherapy after Modified Radical Mastectomy

    International Nuclear Information System (INIS)

    Hong, Chae Seon; Kim, Jong Sik; Kim, Young Kon; Park, Young Hwan

    2006-01-01

    Post-mastectomy radiotherapy (PMR) is known to decrease loco-regional recurrence. Adequate skin and dermal dose are achieved by adding bolus. The more difficult clinical issue is determining the necessary number of bolus treatment, given the limits of normal skin tolerance. The aim of this study is to evaluate the necessary number of bolus treatment after PMR in patients with breast cancer. Four female breast cancer patients were included in the study. The median age was 53 years(range, 38-74), tumor were left sided in 2 patients and right sided in 2 patients. All patients were treated with postoperative radiotherapy after MRM. Radiotherapy was delivered to the chest wall (C.W) and supraclavicular lymph nodes (SCL) using 4 MV X-ray. The total dose was 50 Gy, in 2 Gy fractions (with 5 times a week). CT was performed for treatment planning, treatment planning was performed using A DAC-Pinnacles 3 (Phillips, USA) for all patients without and with bolus. Bolus treatment plans were generated using image tool (0.5 cm of thickness and 6 cm of width). Dose distribution was analyzed and the increased skin dose rate in the build-up region was computed and the skin dose using TLD-100 chips (Harshaw, USA) was measured. No significant difference was found in dose distribution without and with bolus; C.W coverage was 95-100% of the prescribed dose in both. But, there was remarkable difference in the skin dose to the scar. The skin dose to the scar without and with bolus were 100-105% and 50-75%. The increased skin dose rates in the build-up region for Pt. 1, Pt. 2. Pt. 3 and Pt. 4 were 23.3%, 35.6%, 34.9%, and 41.7%. The results of measured skin dose using TLD-100 chips in the cases without and with bolus were 209.3 cGy and 161.1 cGy, 200 cGy and 150.2 cGy, 211.4 cGy and 160.5 cGy, 198.6 cGy and 155.5 cGy for Pt. 1, Pt. 2, Pt. 3, and Pt. 4. It was concludes through this analysis that the adequate number of bolus treatments is 50-60% of the treatment program. Further, clinical

  11. Improving hydroturbine pressures to enhance salmon passage survival and recovery

    Energy Technology Data Exchange (ETDEWEB)

    Trumbo, Bradly A. [U.S. Army Corp. of Engineers, Walla Walla, WA (United States); Ahmann, Martin L. [U.S. Army Corp. of Engineers, Walla Walla, WA (United States); Renholods, Jon F. [U.S. Army Corp. of Engineers, Walla Walla, WA (United States); Brown, Richard S. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Colotelo, Alison H. A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Deng, Zhiqun [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2013-12-12

    This paper provides an overview of turbine pressure data collection and barotrauma studies relative to fish passage through large Kaplan turbines and how this information may be applied to safer fish passage through turbines. The specific objectives are to 1) discuss turbine pressures defined by Sensor Fish releases; 2) discuss what has been learned about pressure effects on fish and the factors influencing barotrauma associated with simulated turbine passage; 3) elucidate data gaps associated with fish behavior and passage that influence barotrauma during turbine passage; 4) discuss how the results of these studies have led to turbine design criteria for safer fish passage; and 5) relate this information to salmon recovery efforts and safer fish passage for Atlantic and Pacific salmonids.

  12. Tracer-tracer relations as a tool for research on polar ozone loss

    Energy Technology Data Exchange (ETDEWEB)

    Mueller, Rolf

    2010-07-01

    The report includes the following chapters: (1) Introduction: ozone in the atmosphere, anthropogenic influence on the ozone layer, polar stratospheric ozone loss; (2) Tracer-tracer relations in the stratosphere: tracer-tracer relations as a tool in atmospheric research; impact of cosmic-ray-induced heterogeneous chemistry on polar ozone; (3) quantifying polar ozone loss from ozone-tracer relations: principles of tracer-tracer correlation techniques; reference ozone-tracer relations in the early polar vortex; impact of mixing on ozone-tracer relations in the polar vortex; impact of mesospheric intrusions on ozone-tracer relations in the stratospheric polar vortex calculation of chemical ozone loss in the arctic in March 2003 based on ILAS-II measurements; (4) epilogue.

  13. New SPECT tracers: Example of tracers of proteoglycans and melanin

    International Nuclear Information System (INIS)

    Cachin, F.; Mestas, D.; Kelly, A.; Merlin, C.; Veyre, A.; Maublant, J.; Cachin, F.; Chezal, J.M.; Miot-Noirault, E.; Moins, N.; Auzeloux, P.; Vidal, A.; Bonnet-Duquennoy, M.; Boisgard, S.; D'Incan, M.; Madelmont, J.C.; Maublant, J.; Boisgard, S.; D'Incan, M.; Redini, F.; Filaire, M.

    2009-01-01

    The majority of research program on new radiopharmaceuticals turn to tracers used for positron emission tomography (PET). Only a few teams work on new non fluorine labeled tracers. However, the coming of SPECT/CT gamma cameras, the arrival of semi-conductors gamma cameras should boost the development of non-PET tracers. We exhibit in this article the experience acquired by our laboratory in the conception and design of two new non fluorine labelled compounds. The 99m Tc-N.T.P. 15-5 (N.T.P. 15-5 for N-[tri-ethyl-ammonium]-3-propyl-[15]ane-N5) which binds to proteoglycans could be used for the diagnosis and staging of osteoarthritis and chondrosarcoma. The iodo benzamides, specific to the melanin, are nowadays compared to 18 F-fluorodeoxyglucose in a phase III clinical trial for the diagnosis and detection of melanoma metastasis. Our last development focus on N-[2-(diethyl-amino)ethyl]-4 and 2-iodo benzamides respectively B.Z.A. and B.Z.A.2 hetero-aromatic analogues usable for melanoma treatment. (authors)

  14. Cineradiography of the liquid bolus swallow. A study of the speed ot the bolus and peristaltic wave and of movement of the hyoid bone, larynx, and epiglottis

    International Nuclear Information System (INIS)

    Sundgren, P.

    1991-01-01

    In the evaluation of the dysphagic patient, radiology is crucial as a technique for monitoring morphology and function. In particular, high-speed cineradiography can reveal a variety of pharyngeal dysfunctions. However, in the literature and in practice the difference between normal and abnormal function is not always clear. This monography is based on high-speed cineradiographies of swallowing in 75 non-dysphagic volunteers and in 189 dysphagic patients. The purpose was to study whether differences in bolus volumes, patient position, age and gender had any effects on the following parameters: the speed of the peristaltic wave and apex of the liquid barium bolus, the length of movement and the movement pattern of the hyoid bone and larynx, and epiglottic function. The study disclosed that the speed of the bolus, the anterior-superior movement and net movement of the hyoid bone increased significantly with larger bolus volumes. The position of the individual in relation to gravity significantly influenced the speed of peristalsis. In most of the measured parameters there were no differences between non-dysphagic and dysphagic individuals expect for differences in the intrapersonal variations and in the anterior-superior movement of the hyoid bone. In patients with pharyngeal dysfunction the initial stage of the elevation of the larynx was significantly lower than in patients without dysfunction. The approximation of the thyroid cartilage to the hyoid bone was significantly greater in individuals with normal epiglottic function than in those with epiglottic dysmobility. It is suggested that abnormal speed of peristalsis may be a mild form of dysfunction. Measurements of the aforementioned speed and movements can be done if bolus volume, age and position of the patient, film speed and magnifications factors are known. Hypotheses concerning epiglottic function and central control of swallowing are proposed. (au)

  15. The predictive ability of six pharmacokinetic models of rocuronium developed using a single bolus: evaluation with bolus and continuous infusion regimen.

    Science.gov (United States)

    Sasakawa, Tomoki; Masui, Kenichi; Kazama, Tomiei; Iwasaki, Hiroshi

    2016-08-01

    Rocuronium concentration prediction using pharmacokinetic (PK) models would be useful for controlling rocuronium effects because neuromuscular monitoring throughout anesthesia can be difficult. This study assessed whether six different compartmental PK models developed from data obtained after bolus administration only could predict the measured plasma concentration (Cp) values of rocuronium delivered by bolus followed by continuous infusion. Rocuronium Cp values from 19 healthy subjects who received a bolus dose followed by continuous infusion in a phase III multicenter trial in Japan were used retrospectively as evaluation datasets. Six different compartmental PK models of rocuronium were used to simulate rocuronium Cp time course values, which were compared with measured Cp values. Prediction error (PE) derivatives of median absolute PE (MDAPE), median PE (MDPE), wobble, divergence absolute PE, and divergence PE were used to assess inaccuracy, bias, intra-individual variability, and time-related trends in APE and PE values. MDAPE and MDPE values were acceptable only for the Magorian and Kleijn models. The divergence PE value for the Kleijn model was lower than -10 %/h, indicating unstable prediction over time. The Szenohradszky model had the lowest divergence PE (-2.7 %/h) and wobble (5.4 %) values with negative bias (MDPE = -25.9 %). These three models were developed using the mixed-effects modeling approach. The Magorian model showed the best PE derivatives among the models assessed. A PK model developed from data obtained after single-bolus dosing can predict Cp values during bolus and continuous infusion. Thus, a mixed-effects modeling approach may be preferable in extrapolating such data.

  16. Endoscopic evaluation of food bolus formation and its relationship with the number of chewing cycles.

    Science.gov (United States)

    Fukatsu, H; Nohara, K; Kotani, Y; Tanaka, N; Matsuno, K; Sakai, T

    2015-08-01

    It is known that solid food is transported to the pharynx actively in parallel to it being crushed by chewing and mixed with saliva in the oral cavity. Therefore, food bolus formation should be considered to take place from the oral cavity to the pharynx. In previous studies, the chewed food was evaluated after the food had been removed from the oral cavity. However, it has been pointed out that spitting food out of the oral cavity interferes with natural food bolus formation. Therefore, we observed food boluses immediately before swallowing using an endoscope to establish a method to evaluate the food bolus-forming function, and simultaneously performed endoscopic evaluation of food bolus formation and its relationship with the number of chewing cycles. The subject was inserted the endoscope nasally and instructed to eat two coloured samples of boiled rice simultaneously in two ingestion conditions ('as usual' and 'chewing well'). The condition of the food bolus was graded into three categories for each item of grinding, mixing and aggregation and scored 2, 1 and 0. The score of aggregation was high under both ingestion conditions. The scores of grinding and mixing tended to be higher in subjects with a high number of chewing cycles, and the score of aggregation was high regardless of the number of chewing cycles. It was suggested that food has to be aggregated, even though the number of chewing cycles is low and the food is not ground or mixed for a food bolus to reach the swallowing threshold. © 2015 John Wiley & Sons Ltd.

  17. Characterization of swallow modulation in response to bolus volume in healthy subjects accounting for catheter diameter.

    Science.gov (United States)

    Ferris, Lara; Schar, Mistyka; McCall, Lisa; Doeltgen, Sebastian; Scholten, Ingrid; Rommel, Nathalie; Cock, Charles; Omari, Taher

    2018-06-01

    Characterization of the pharyngeal swallow response to volume challenges is important for swallowing function assessment. The diameter of the pressure-impedance recording catheter may influence these results. In this study, we captured key physiological swallow measures in response to bolus volume utilizing recordings acquired by two catheters of different diameter. Ten healthy adults underwent repeat investigations with 8- and 10-Fr catheters. Liquid bolus swallows of volumes 2.5, 5, 10, 20, and 30 mL were recorded. Measures indicative of distension, contractility, and flow timing were assessed. Pressure-impedance recordings with pressure-flow analysis were used to capture key distension, contractility, and pressure-flow timing parameters. Larger bolus volumes increased upper esophageal sphincter distension diameter (P < .001) and distension pressures within the hypopharynx and upper esophageal sphincter (P < .05). Bolus flow timing measures were longer, particularly latency of bolus propulsion ahead of the pharyngeal stripping wave (P < .001). Use of a larger-diameter catheter produced higher occlusive pressures, namely upper esophageal sphincter basal pressure (P < .005) and upper esophageal sphincter postdeglutitive pressure peak (P < .001). The bolus volume swallowed changed measurements indicative of distension pressure, luminal diameter, and pressure-flow timing; this is physiologically consistent with swallow modulation to accommodate larger, faster-flowing boluses. Additionally, catheter diameter predominantly affects lumen occlusive pressures. Appropriate physiological interpretation of the pressure-impedance recordings of pharyngeal swallowing requires consideration of the effects of volume and catheter diameter. NA. Laryngoscope, 128:1328-1334, 2018. © 2017 The American Laryngological, Rhinological and Otological Society, Inc.

  18. Condensation phenomena in a turbine blade passage

    International Nuclear Information System (INIS)

    Skillings, S.A.

    1989-02-01

    The mechanisms associated with the formation and growth of water droplets in the large low-pressure (LP) turbines used for electrical power generation are poorly understood and recent measurements have indicated that an unusually high loss is associated with the initial nucleation of these droplets. In order to gain an insight into the phenomena which arise in the turbine situation, some experiments were performed to investigate the behaviour of condensing steam flows in a blade passage. This study has revealed the fundamental significance of droplet nucleation in modifying the single-phase flow structure and results are presented which show the change in shock wave pattern when inlet superheat and outlet Mach number are varied. The trailing-edge shock wave structure appears considerably more robust towards variation of inlet superheat than purely one-dimensional considerations may suggest and the inadequacies of adopting a one-dimensional theory to analyse multi-dimensional condensing flows are demonstrated. Over a certain range of outlet Mach numbers an oscillating shock wave will establish in the throat region of the blade passage and this has been shown to interact strongly with droplet nucleation, resulting in a considerably increased mean droplet size. The possible implications of these results for turbine performance are also discussed. (author)

  19. Fifty years of radiochemical tracers

    International Nuclear Information System (INIS)

    Evans, E.A.

    1992-01-01

    During the past 50 years radiochemical tracers, usually in the form of isotopically labelled organic compounds, have been essential tools to further advance our knowledge at the frontiers of a great variety of scientific developments in the life sciences. This plenary lecture reviews necessarily selected highlights in the synthesis and applications of such radiochemical tracers. Included are examples where important advances, made possible by using radiochemicals, have contributed to improving the quality of life on this planet. The principal radioisotopes involved, 14 C, 3 H, 35 S, 32 P, 125 I, are all relatively safe to handle and are commercially available at maximum theoretical specific activity (carrier free). The compounds labeled with these radioisotopes are used in many fields of research which include biosynthesis and biotechnology studies, cell biology, drug metabolism, clinical research and environmental applications, and are briefly reviewed. (author). 55 refs

  20. Tracer techniques in food industry

    International Nuclear Information System (INIS)

    Pertsovskij, E.S.; Sakharov, Eh.V.; Dolinin, V.A.

    1980-01-01

    The appicability of radioactive tracer techniques to process control in food industry are considered. Investigations in the field of food industry carried out using the above method are classified. The 1 class included investigations with preliminary preparation of a radioactive indicator and its following introduction in the system studied. The 2 class includes investigations based on the introduction in the system studied of a non-active indicator which is activated in a neutron flux being in samples selected in or after the process investigated. The 3 class includes studies based on investigations of natural radioactivity of certain nuclides in food stuff. The application of tracer techniques to the above classes of investigations in various fields of food industry and the equipment applied are considered in detail [ru

  1. Kinetic analysis of 18F-fluorodihydrorotenone as a deposited myocardial flow tracer: Comparison to thallium-201.

    Energy Technology Data Exchange (ETDEWEB)

    Marshall, Robert C.; Powers-Risius, Patricia; Reutter, Bryan W.; O' Neil, James P.; La Belle, Michael; Huesman, Ronald H.; VanBrocklin, Henry F.

    2004-03-01

    The goal of this investigation was to assess the accuracy of 18F-fluorodihydrorotenone (18F-FDHR) as a new deposited myocardial flow tracer and compare the results to those for 201Tl. Methods. The kinetics of these flow tracers were evaluated in 22 isolated, erythrocyte- and albumin-perfused rabbit hearts over a flow range encountered in patients. The two flow tracers plus a vascular reference tracer (131I-albumin) were introduced as a bolus through a port just above the aortic cannula. Myocardial extraction, retention, washout, and uptake parameters were computed from the venous outflow curves using the multiple indicator dilution technique and spectral analysis. Results. The mean initial extraction fractions of 18F-FDHR (0.85 +- 0.07) and 201Tl (0.87 +- 0.05) were not significantly different, although the initial extraction fraction for 18F-FDHR declined with flow (P < 0.0001), whereas the initial extraction fraction of 201Tl did not. Washout of 201Tl was faster (P < 0.001) and more affected by flow (P < 0.05) than 18F-FDHR washout. Except for initial extraction fraction, 18F-FDHR retention was greater (P < 0.001) and less affected by flow (P < 0.05) than 201Tl retention. Reflecting its superior retention, net uptake of 18F-FDHR was better correlated with flow than 201Tl uptake at both one and fifteen minutes after tracer introduction (P < 0.0001 for both comparisons). Conclusion. The superior correlation of 18F-FDHR uptake with flow indicates that it is a better flow tracer than 201Tl in the isolated rabbit heart. Compared to the other currently available positron-emitting flow tracers (82Rb, 13N-ammonia, and 15O-water), 18F-FDHR has the potential of providing excellent image resolution without the need for an on-site cyclotron.

  2. The Accurate Particle Tracer Code

    OpenAIRE

    Wang, Yulei; Liu, Jian; Qin, Hong; Yu, Zhi

    2016-01-01

    The Accurate Particle Tracer (APT) code is designed for large-scale particle simulations on dynamical systems. Based on a large variety of advanced geometric algorithms, APT possesses long-term numerical accuracy and stability, which are critical for solving multi-scale and non-linear problems. Under the well-designed integrated and modularized framework, APT serves as a universal platform for researchers from different fields, such as plasma physics, accelerator physics, space science, fusio...

  3. Fracture Characterization in Reactive Fluid-Fractured Rock Systems Using Tracer Transport Data

    Science.gov (United States)

    Mukhopadhyay, S.

    2014-12-01

    Fractures, whether natural or engineered, exert significant controls over resource exploitation from contemporary energy sources including enhanced geothermal systems and unconventional oil and gas reserves. Consequently, fracture characterization, i.e., estimating the permeability, connectivity, and spacing of the fractures is of critical importance for determining the viability of any energy recovery program. While some progress has recently been made towards estimating these critical fracture parameters, significant uncertainties still remain. A review of tracer technology, which has a long history in fracture characterization, reveals that uncertainties exist in the estimated parameters not only because of paucity of scale-specific data but also because of knowledge gaps in the interpretation methods, particularly in interpretation of tracer data in reactive fluid-rock systems. We have recently demonstrated that the transient tracer evolution signatures in reactive fluid-rock systems are significantly different from those in non-reactive systems (Mukhopadhyay et al., 2013, 2014). For example, the tracer breakthrough curves in reactive fluid-fractured rock systems are expected to exhibit a long pseudo-state condition, during which tracer concentration does not change by any appreciable amount with passage of time. Such a pseudo-steady state condition is not observed in a non-reactive system. In this paper, we show that the presence of this pseudo-steady state condition in tracer breakthrough patterns in reactive fluid-rock systems can have important connotations for fracture characterization. We show that the time of onset of the pseudo-steady state condition and the value of tracer concentration in the pseudo-state condition can be used to reliably estimate fracture spacing and fracture-matrix interface areas.

  4. Delivery confirmation of bolus electron conformal therapy combined with intensity modulated x-ray therapy

    International Nuclear Information System (INIS)

    Kavanaugh, James A.; Hogstrom, Kenneth R.; Fontenot, Jonas P.; Henkelmann, Gregory; Chu, Connel; Carver, Robert A.

    2013-01-01

    Purpose: The purpose of this study was to demonstrate that a bolus electron conformal therapy (ECT) dose plan and a mixed beam plan, composed of an intensity modulated x-ray therapy (IMXT) dose plan optimized on top of the bolus ECT plan, can be accurately delivered. Methods: Calculated dose distributions were compared with measured dose distributions for parotid and chest wall (CW) bolus ECT and mixed beam plans, each simulated in a cylindrical polystyrene phantom that allowed film dose measurements. Bolus ECT plans were created for both parotid and CW PTVs (planning target volumes) using 20 and 16 MeV beams, respectively, whose 90% dose surface conformed to the PTV. Mixed beam plans consisted of an IMXT dose plan optimized on top of the bolus ECT dose plan. The bolus ECT, IMXT, and mixed beam dose distributions were measured using radiographic films in five transverse and one sagittal planes for a total of 36 measurement conditions. Corrections for film dose response, effects of edge-on photon irradiation, and effects of irregular phantom optical properties on the Cerenkov component of the film signal resulted in high precision measurements. Data set consistency was verified by agreement of depth dose at the intersections of the sagittal plane with the five measured transverse planes. For these same depth doses, results for the mixed beam plan agreed with the sum of the individual depth doses for the bolus ECT and IMXT plans. The six mean measured planar dose distributions were compared with those calculated by the treatment planning system for all modalities. Dose agreement was assessed using the 4% dose difference and 0.2 cm distance to agreement. Results: For the combined high-dose region and low-dose region, pass rates for the parotid and CW plans were 98.7% and 96.2%, respectively, for the bolus ECT plans and 97.9% and 97.4%, respectively, for the mixed beam plans. For the high-dose gradient region, pass rates for the parotid and CW plans were 93.1% and 94

  5. Transient tracers in the ocean (TTO) program: the North Atlantic study, 1981: the Tropical Atlantic study, 1983

    International Nuclear Information System (INIS)

    Brewer, P.G.; Sarmiento, J.L.; Smethie, W.M. Jr.

    1985-01-01

    The two parts of this major geochemical and physical oceanographic expedition took place on the research vessel Knorr of the Woods Hole Oceanographic Institution. The expeditions were designed to observe the passage of man-made geochemical tracers into the interior of the ocean. A systematic survey revealed the penetration into the thermocline and deep ocean of the products of man's military/industrial activities, principally tritium and carbon-14 resulting from atmospheric testing of nuclear weapons. The passage of these tracers documents as nothing else can the manner and time scale of ocean mixing and provides a fundamental calibration for models of ocean circulation. Maps showing the cruise routes are presented. 1 figure, 1 table

  6. Assessment of injection bolus in first-pass radionuclide angiography. Evaluation of injection site and needle size

    International Nuclear Information System (INIS)

    Tonami, Syuichi; Inagaki, Syoichi; Yasui, Masakazu; Sugishita, Kouki; Yoshita, Hisashi; Nakamura, Mamoru; Kuranishi, Makoto

    1996-01-01

    First-pass radionuclide angiography (FPRNA) using a multi-crystal gamma camera can correctly provide many quantitative and qualitative indices of left ventricular function as well as anatomic information. A compact injection bolus of radiotracer is, however, essential to the first-pass study since the temporal separation of cardiac chambers is required for the first-pass acquisition. To examine which factors affect the quality of an injection bolus, 327 patients who had FPRNA in the anterior projection were randomized for injection site of radiotracer (right or left external jugular veins, and right antecubital vein) and needle size (19- or 21-gauge). The injected bolus was assessed from the full width at half maximum (FWHM) of the bolus time-activity curve in the superior vena cava. As to injection site using a 19-gauge needle, an attemption through right external jugular vein (EJV) revealed the shortest FWHM of an injection bolus, followed by left EJV and right antecubital vein (AV). In right EJV 91% of injected bolus FWHM was less than 1.5 sec, which was significantly higher (p<0.001) than those of the other sites (left EJV: 70%. right AV: 65%). Approximately 7% of injection from left EJV and right AV, showed a split bolus of radiotracer. However, no split bolus was observed from right EJV. There was no significant difference in FWHM of an injection bolus between 19- and 21-gauge needle from EJV. Our present study demonstrated that the quality of an injection bolus from left EJV and AV was affected by RVEF in a case of low right ventricular function. In conclusion, right EJV is the first choice of injection site to obtain a compact bolus of radiotracer for the first-pass cardiac study. A 21-gauge needle can also be inserted from the external jugular vein to perform a good bolus injection. (author)

  7. Assessment of injection bolus in first-pass radionuclide angiography. Evaluation of injection site and needle size

    Energy Technology Data Exchange (ETDEWEB)

    Tonami, Syuichi; Inagaki, Syoichi; Yasui, Masakazu; Sugishita, Kouki; Yoshita, Hisashi; Nakamura, Mamoru; Kuranishi, Makoto [Toyama Medical and Pharmaceutical Univ. (Japan). Hospital

    1996-09-01

    First-pass radionuclide angiography (FPRNA) using a multi-crystal gamma camera can correctly provide many quantitative and qualitative indices of left ventricular function as well as anatomic information. A compact injection bolus of radiotracer is, however, essential to the first-pass study since the temporal separation of cardiac chambers is required for the first-pass acquisition. To examine which factors affect the quality of an injection bolus, 327 patients who had FPRNA in the anterior projection were randomized for injection site of radiotracer (right or left external jugular veins, and right antecubital vein) and needle size (19- or 21-gauge). The injected bolus was assessed from the full width at half maximum (FWHM) of the bolus time-activity curve in the superior vena cava. As to injection site using a 19-gauge needle, an attemption through right external jugular vein (EJV) revealed the shortest FWHM of an injection bolus, followed by left EJV and right antecubital vein (AV). In right EJV 91% of injected bolus FWHM was less than 1.5 sec, which was significantly higher (p<0.001) than those of the other sites (left EJV: 70%. right AV: 65%). Approximately 7% of injection from left EJV and right AV, showed a split bolus of radiotracer. However, no split bolus was observed from right EJV. There was no significant difference in FWHM of an injection bolus between 19- and 21-gauge needle from EJV. Our present study demonstrated that the quality of an injection bolus from left EJV and AV was affected by RVEF in a case of low right ventricular function. In conclusion, right EJV is the first choice of injection site to obtain a compact bolus of radiotracer for the first-pass cardiac study. A 21-gauge needle can also be inserted from the external jugular vein to perform a good bolus injection. (author)

  8. The impact of mastication, salivation and food bolus formation on salt release during bread consumption.

    Science.gov (United States)

    Tournier, Carole; Grass, Manon; Septier, Chantal; Bertrand, Dominique; Salles, Christian

    2014-11-01

    Health authorities recommend higher fibre and lower salt content in bread products. However, these basic ingredients of bread composition are multifunctional, and important changes in their content influence the texture, flavour and acceptability of the product. This study was designed to investigate the link between oral processing, bolus formation and sodium release during the consumption of four different breads that varied in composition and structure. Chewing behaviour was determined by surface electromyography, and salivation was quantified from the water content of the boluses collected. The kinetics of bread degradation during food bolus formation was characterised by measuring the bolus heterogeneity by texture image analysis, and sodium release into the saliva was quantified. Mastication and salivation varied between products and between subjects, thus highlighting different bolus formation strategies. In vivo salt release was mainly explained by mastication parameters. The initial slope of sodium release increased when the chewing muscles' activity increased, and the maximum sodium concentration was reached later when more masticatory cycles were required to reach the swallowing point.

  9. Impacts of palatal coverage on bolus formation during mastication and swallowing and subsequent adaptive changes.

    Science.gov (United States)

    Sato, T; Furuya, J; Tamada, Y; Kondo, H

    2013-10-01

    Palatal coverage is often required for elderly edentulous patients with complete dentures. The purpose of this study was to clarify impacts of palatal coverage on bolus formation and subsequent adaptive changes. Subjects were 18 healthy young dentulous adults who wore 1·5-mm-thick palatal plates. Subjects were asked to feed 12 g of bicoloured rice as usual, and the bolus formation by mastication and swallowing in the pharynx was observed using a nasal videoendoscopy. The bolus formation index (BFI), number of mastication strokes until swallowing, visual analogue scale about swallowing easiness and masticatory performance using colour-changeable gum were measured under three conditions: before placement of the palatal plate (day 0), immediately after placement (day 1) and after 7 days of wearing the plate (day 7). BFI and visual analogue scale on day 1 were significantly lower than those on day 0, but those on day 7 significantly recovered to the level of day 0. The number of mastication strokes did not change from day 0 to day 1, however, that on day 7 was significantly higher. Masticatory performance on days 1 and 7 was significantly lower than that on day 0. Although palatal coverage inhibits bolus formation during feeding, subjects increased the number of mastication strokes until swallowing threshold as they adapted to palatal coverage over time. This adaptive change was due to compensate for the lowered masticatory performance to achieve bolus formation for comfortable swallowing. © 2013 John Wiley & Sons Ltd.

  10. Saving radiation dose and contrast media in intravenous digital subtraction angiography by use of bolus chasing

    International Nuclear Information System (INIS)

    Rueckforth, J.; Schuermann, K.; Vorwerk, D.; Guenther, R.W.

    1998-01-01

    Purpose: This study evaluates the dose area product, the amount of contrast media and the examination quality of the bolus chasing technique compared to the single-step technique in intravenous digital subtraction angiography. Material and Methods: 15 examinations each with bolus chasing and single-step technique were compared. The dose area product and the volume of contrast media were recorded. The examination quality was scored by two examiners. Results: With bolus chasing the volume of the administered contrast media could be decreased on average by 114 ml (43%). The difference between the dose area product of bolus chasing (722 dGy/cm 2 ) and single-step technique (1910 dGy/cm 2 ) was significant. No significant difference in examination quality was found. Conclusions: The intravenous bolus chasing technique is a practicable method. Compared to the single-step technique it allows a remarkable dose reduction and a low consumption of contrast media without restriction of examination quality. (orig.) [de

  11. Endoleak detection using single-acquisition split-bolus dual-energy computer tomography (DECT)

    Energy Technology Data Exchange (ETDEWEB)

    Javor, D.; Wressnegger, A.; Unterhumer, S.; Kollndorfer, K.; Nolz, R.; Beitzke, D.; Loewe, C. [Medical University of Vienna, Department of Biomedical Imaging and Image-guided Therapy, Vienna (Austria)

    2017-04-15

    To assess a single-phase, dual-energy computed tomography (DECT) with a split-bolus technique and reconstruction of virtual non-enhanced images for the detection of endoleaks after endovascular aneurysm repair (EVAR). Fifty patients referred for routine follow-up post-EVAR CT and a history of at least one post-EVAR follow-up CT examination using our standard biphasic (arterial and venous phase) routine protocol (which was used as the reference standard) were included in this prospective trial. An in-patient comparison and an analysis of the split-bolus protocol and the previously used double-phase protocol were performed with regard to differences in diagnostic accuracy, radiation dose, and image quality. The analysis showed a significant reduction of radiation dose of up to 42 %, using the single-acquisition split-bolus protocol, while maintaining a comparable diagnostic accuracy (primary endoleak detection rate of 96 %). Image quality between the two protocols was comparable and only slightly inferior for the split-bolus scan (2.5 vs. 2.4). Using the single-acquisition, split-bolus approach allows for a significant dose reduction while maintaining high image quality, resulting in effective endoleak identification. (orig.)

  12. Effect of chest wall radiotherapy in different manners using tissue equivalent bolus on skin and lung of cavia cobayas

    International Nuclear Information System (INIS)

    Huang Wei; Qu Yaqin; Song Xiangfu; Liu Shixin; Jia Xiaojing; Guo He; Yang Lei

    2009-01-01

    Objective: To probe the influence of electron beam radiotherapy in different manners using different tissue equivalent boluses on skin and lung. Methods: Adult female cavia cobayas were randomly divided into four groups as control group, half-time with bolus group, half-time with bolus group and without bolus group. Acute-irradiation animal models were established using electron beam in different manners with or without 0.5 cm tissue equivalent bolus. Pathological changes in lung, hair vesicle and fibroblast cell count were analyzed 40 clays after irradiation. Results: The radiation dermatitis in the group with bolus was slighter than that of the group without bolus, but the radiation pneumonia was reverse. With bolus, the radiation dermatitis of haft-time group was slighter than that of full-time group. The injury repair of half-time group was more active than full-time group. Conclusions: The treatment of haft-time bolus could protect lung without serious skin complications. (authors)

  13. The microclimate within a Neolithic passage grave

    DEFF Research Database (Denmark)

    Klenz Larsen, Poul; Aasbjerg Jensen, Lars; Ryhl-Svendsen, Morten

    2017-01-01

    Microclimate measurements in a Neolithic passage grave in Denmark have shown that natural ventilation through the open entrance destabilizes the relative humidity (RH), whereas a sealed entrance gives a much more stable RH, above 90%. Episodes of condensation occur on the stone surfaces in summer...... with too much ventilation and in winter with too little ventilation. Soil moisture measurements above, below, and beside the grave mound indicate that rainfall on the mound is not a significant source of moisture to the chamber, whereas the ground below the sealed chamber is constantly moist. The chamber...... can be kept dry all year by putting a moisture barrier membrane over the floor. Apart from the more variable climate within the open chamber, there is also a significant penetration of ozone, which is absent in the sealed chamber. The ozone may have deteriorated the folds of birch bark put between...

  14. Bird of passage recollections of a physicist

    CERN Document Server

    1985-01-01

    Here is the intensely personal and often humorous autobiography of one of the most distinguished theoretical physicists of his generation, Sir Rudolf Peierls. Born in Germany in 1907, Peierls was indeed a bird of passage," whose career of fifty-five years took him to leading centers of physics--including Munich, Leipzig, Zurich, Copenhagen, Cambridge, Manchester, Oxford, and J. Robert Oppenheimer''s Los Alamos. Peierls was a major participant in the revolutionary development of quantum mechanics in the 1920s and 1930s, working with some of the pioneers and, as he puts it, "some of the great characters" in this field. Originally published in 1988. The Princeton Legacy Library uses the latest print-on-demand technology to again make available previously out-of- print books from the distinguished backlist of Princeton University Press. These paperback editions preserve the original texts of these important books while presenting them in durable paperback editions. The goal of the Princeton Legacy Libr...

  15. Critical behavior of the two-dimensional first passage time

    International Nuclear Information System (INIS)

    Chayes, J.T.; Chayes, L.; Durrett, R.

    1986-01-01

    We study the two-dimensional first passage problem in which bonds have zero and unit passage times with probability p and 1-p, respectively. We provide that as the zero-time bonds approach the percolation threshold p/sub c/, the first passage time exhibits the same critical behavior as the correlation function of the underlying percolation problem. In particular, if the correlation length obeys ξ(p)--chemical bondp-p/sub c/chemical bond/sup -//sup v/, then the first passage time constant satisfies μ(p)--chemical bondp-p/sub c/chemical bond/sup v/. At p/sub c/, where it has been asserted that the first passage time from 0 to x scales as chemical bondxchemical bond to a power psi with 0< psi<1, we show that the passage times grow like log chemical bondxchemical bond, i.e., the fluid spreads exponentially rapidly

  16. The future of fish passage science, engineering, and practice

    DEFF Research Database (Denmark)

    Silva, Ana T.; Lucas, Martyn C.; Castro-Santos, Theodore

    2018-01-01

    science today involves a wide range of disciplines from fish behaviour to socioeconomics to complex modelling of passage prioritization options in river networks. River barrier impacts on fish migration and dispersal are currently better understood than historically, but basic ecological knowledge......Much effort has been devoted to developing, constructing and refining fish passage facilities to enable target species to pass barriers on fluvial systems, and yet, fishway science, engineering and practice remain imperfect. In this review, 17 experts from different fish passage research fields (i...... underpinning the need for effective fish passage in many regions of the world, including in biodiversity hotspots (e.g., equatorial Africa, South-East Asia), remains largely unknown. Designing efficient fishways, with minimal passage delay and post-passage impacts, requires adaptive management and continued...

  17. Effects of copper oxide wire particle bolus therapy on trichostrongyle fecal egg counts in exotic artiodactylids.

    Science.gov (United States)

    Fontenot, Deidre K; Kinney-Moscona, Allyson; Kaplan, Ray M; Miller, James

    2008-12-01

    Four species of artiodactylids (scimitar-horned oryx [Oryx dama]), roan antelope [Hippotragus equinus], blackbuck [Antilope cervicapra]), and blesbok [Damaliscus pygargus phillipsi]) totaling 13 animals were treated with a one-time 12.5-g dose of copper oxide wire particles (COWPs) in a bolus form. Pretreatment, individual trichostrongyle fecal egg counts (FECs) were performed using the McMaster technique. Individual posttreatment FECs were performed every 7 days for 35 days beginning 7 days after bolus administration, and FEC reduction ratios (FECRRs) expressed as percentage reductions from pretreatment values were calculated every 7 days. Mean FECRRs for the 13 animals were 93% +/- 16%, 98% +/- 7%, 91% +/- 28%, 94% +/- 16%, and 90% +/- 13% at 7, 14, 21, 28, and 35 days posttreatment, respectively. These data demonstrate that COWPs in a bolus form were an effective method for reducing FEC in exotic artiodactylids. Based on this limited data, COWPs show promise as an anthelmintic alternative for exotic artiodactylids in zoologic collections.

  18. Study of dose modification in skin cancers induced by the kind of bolus used - Bibliography

    International Nuclear Information System (INIS)

    Camilleri, Jeremy

    2011-01-01

    As tumour irradiation modalities differ from one pathology to another, and are even proper to each pathology (they depend on tumour nature, histology, size, location, and so on), but as therapeutic objectives remain unchanged (to deliver the prescribed dose to the target-volume with the highest possible precision while preserving as much as possible sane tissues as well as neighbouring organs at risk), this bibliographical study aims, on the one hand, at quantifying the dose variation generated by heterogeneous structures crossed by the electron beam, and on the other hand, at optimising the use of boluses during surface irradiations, notably in the case of skin cancers. The author addresses therapeutic indications of irradiation of skin cancers and of thoracic wall for which the application of a bolus is required, and then the associated irradiation techniques as well as bolus characteristics

  19. Comparison of Bolus Phenylephrine, Ephedrine and Mephentermine for Maintenance of Arterial Pressure during Spinal Anesth

    Directory of Open Access Journals (Sweden)

    B Bhattarai

    2010-03-01

    Full Text Available INTRODUCTION: Hypotension is common following spinal anesthesia. Various vasopressors have been indicated to prevent it. The study compares three such agents namely phenylephrine, ephedrine and mephentermine. METHODS: The study included 90 patients undergoing elective and emergency cesarean section who developed hypotension following subarachnoid blockade. Parturient were randomly divided into three groups each group had 30 patients. Group P received bolus of Phenylephrine 25 microgram, where as group E received Ephedrine 5mg and Group M received Mephentermine 6mg. RESULTS: It was found that rise of blood pressure was significantly higher in case of phenylephrine group in first six minutes, after the bolus, there was significant reduction in the heart rate in phenylephrine group, but there was tachycardia following administration of bolus ephedrine and mephenteramine. Neonatal APGAR score were similar in all three groups. CONCLUSIONS: All three drugs maintained hemodynamics within 20 percent of the baseline values on intravenous administration. Keywords: APGAR, ephedrine, hypotension, mephentermine, phenylephrine, spinal anesthesia.

  20. Dynamic computed tomography after bolus injection and infusion of perfluorooctylbromide (PFOB)

    International Nuclear Information System (INIS)

    Adam, G.; Guenther, R.W.; Goertz, H.; Schiffer, C.

    1992-01-01

    We investigated the enhancement of the liver, the spleen, and of induced abscesses and the abdominal vessels after administration of 3 g/kg bodyweight Perfluoroocytlbromide (PFOB) on an animal model. Twenty-one rabbits each received the contrast medium as bolus injection and as slow infusion over half an hour. CT was performed between 2 and 48 hours after contrast medium application. Peak enhancement of the liver, the spleen and the liver abscess membrane was found between 24 and 48 hours after PFOB administration, independently of the application mode. Peak enhancement of the abdominal aorta and the IVC was observed within two hours after bolus injection. In this rabbit model PFOB permits best delineation of the vessels after bolus injection within the first two hours, while CT imaging of the liver, the spleen and the liver abscess membrane is best between 24 and 48 hours after contrast medium application, independent of the injection velocity. (orig.) [de

  1. Development of test bolus tracking method and usefulness in coronary CT angiography

    International Nuclear Information System (INIS)

    Yamaguchi, Takayoshi; Takahashi, Daichi

    2009-01-01

    The test bolus tracking (TBT) method is a new injection method of contrast medium that we developed. The TBT method is an injection technique that continuously performs the test bolus injection and the main bolus injection, such that the best acquisition of scan timing and the improvement of examination efficiency can be expected. We compared the TBT method and the test injection method by coronary CT angiography. The results demonstrated that the contrast enhancement of the coronary arteries was high and the variation of the CT value was also small in the TBT method. When the scan timing expected by the TI method and the TBT method were compared, it was different of two seconds or more by the case with 43%. However, the variation of CT value was small for the TBT method in these cases. Therefore, the TBT method is a very useful method for coronary CT angiography (CCTA). (author)

  2. Rapid contrast infusion of bolus injection for i.v. urography

    International Nuclear Information System (INIS)

    Kaltenborn, H.; Klose, P.; Klose, K.; Schmiedel, E.

    1993-01-01

    The rate of contrast injection during i.v. urography may vary considerably (bolus injection or drip infusion). The effect of 5 rates of injection (6, 12, 18, 36 and 72 ml/min) on the contrast density in the renal collecting system was examined over a period of 30 minutes. Measurements showed an inter-individual difference of more than 200% in each group. The intra-individual variations for different rates of injection were very slight; individual concentration in the kidney for a given dose depends only slightly on the rate of injection. There is no statistically significant improvement in contrast values as a result of a bolus injection. The reduced incidence of side effects justifies the use of bolus injections but pressure injections are unnecessary from a diagnostic point view. (orig.) [de

  3. A custom three-dimensional electron bolus technique for optimization of postmastectomy irradiation

    International Nuclear Information System (INIS)

    Perkins, George H.; McNeese, Marsha D.; Antolak, John A.; Buchholz, Thomas A.; Strom, Eric A.; Hogstrom, Kenneth R.

    2001-01-01

    Purpose: Postmastectomy irradiation (PMI) is a technically complex treatment requiring consideration of the primary tumor location, possible risk of internal mammary node involvement, varying chest wall thicknesses secondary to surgical defects or body habitus, and risk of damaging normal underlying structures. In this report, we describe the application of a customized three-dimensional (3D) electron bolus technique for delivering PMI. Methods and Materials: A customized electron bolus was designed using a 3D planning system. Computed tomography (CT) images of each patient were obtained in treatment position and the volume to be treated was identified. The distal surface of the wax bolus matched the skin surface, and the proximal surface was designed to conform to the 90% isodose surface to the distal surface of the planning target volume (PTV). Dose was calculated with a pencil-beam algorithm correcting for patient heterogeneity. The bolus was then fabricated from modeling wax using a computer-controlled milling device. To aid in quality assurance, CT images with the bolus in place were generated and the dose distribution was computed using these images. Results: This technique optimized the dose distribution while minimizing irradiation of normal tissues. The use of a single anterior field eliminated field junction sites. Two patients who benefited from this option are described: one with altered chest wall geometry (congenital pectus excavatum), and one with recurrent disease in the medial chest wall and internal mammary chain (IMC) area. Conclusion: The use of custom 3D electron bolus for PMI is an effective method for optimizing dose delivery. The radiation dose distribution is highly conformal, dose heterogeneity is reduced compared to standard techniques in certain suboptimal settings, and excellent immediate outcome is obtained

  4. The Consideration of Bolus Effects of Games Attached on Lesion area

    International Nuclear Information System (INIS)

    Park, Ju Young; Ju, Sang Kyu; Park, Young Chul; Han, Young Yi; Shin, Eun Hyuk; Park, Yong Hwan

    2004-01-01

    The aim of this study is to evaluate the effect of skin dose and PDD by using wounds protecting gauzes or Vaselinespread gauzes. And it was studied that the possibility to substitute custom bolus into gauzes. 4 MV photon (CL600C, varian, US), Polystyrene Phantom (30(W) X 30(L) X 30(H)) with Markus chamber(PTW, US) were used for dose measurement. This study was distinguished natural gauzes and spread over Vaseline gauzes. We gave variety to the gauze thickness at 5, 10 and 15 sheets respectively. For comparison between using bolus and not that, we had used 1.0 cm thickness bolus so that analyzed surface dose and PDD at the same conditions above mentioned. When maximum point was defined as reference point, surface dose was measured as 35% in open beam. When the gauzes were attached to surface as 5, 10 and 15 sheets, surface dose were increased as 69, 80 and 91% respectively according to thickness of gauzes. When spread over Vaseline gauzes were attached to surface as 5, 10 and 15 sheets, surface dose were increased respectively as 98, 100 and 98% according to thickness of gauzes. Also when 0.5 cm bolus and 5 sheets gauzes were composed, surface dose was measured as 98%. The gauzes that were attached to skin surface in radiation therapy had been scattering material and contributed increasing surface dose without variation of percentage depth dose. However, if we want to delivery much dose to skin surface then we have to apply many sheets of gauzes to skin surface. Although we get easy that result by bolus or spread over Vaseline gauzes, we have to revise percentage depth dose at calculation. Therefore, if we find pertinent conditions based on measured data that are considered skin dose and patient setup efficiency, to replace custom bolus with gauzes will be helpful to efficient treatment.

  5. Oral declines and mastication deficiencies cause alteration of food bolus properties.

    Science.gov (United States)

    Peyron, M-A; Santé-Lhoutellier, V; François, O; Hennequin, M

    2018-02-21

    In the elderly, masticatory function often presents failure in certain oral tasks due to impairment such as decline in muscular force, jaw or tongue motility, neuro-muscular coordination, tooth damage, malocclusion and saliva production. Great disparity is observed in the various and potentially cumulative oral declines that occur with ageing. Such difficulties may have an impact on food consumption and nutritional status. To obtain better understanding of the consequences of several oral deficiencies, a series of swallowable boluses were prepared in vitro with the AM 2 masticator apparatus with normal and deficient programming. Physiological normal mastication (NM) was simulated using in vivo data from healthy subjects. Chewing deficiencies were reproduced by alteration of NM programming to perform different levels and combinations of force loss, lack of saliva and decrease in the motility of oral elements. Poultry meatballs were used as test-food. Particle size distribution in the food bolus was measured by sieving and rheological features (hardness, cohesiveness and elasticity) were assessed with a TPA test. Compared to the NM outcome, significant and gradual deterioration of the food bolus was observed and associated with alteration in force, saliva and motility. Combinations of several failures led to greater or cumulative deficiencies in swallowable bolus properties. For the elderly presenting a high prevalence of various oral injuries, tailoring textured food cannot be ignored as a solution for remedying deficiencies and favoring the formation of a safe-swallowable bolus, which is an essential vector of nutrients. Knowing the impacts of oral injuries on the food bolus is obviously a requisite for developing diet strategies, including nutritional items for specific populations.

  6. Use of stable helium tracer for the early detection of impaired pulmonary function

    International Nuclear Information System (INIS)

    Susskind, H.; Richards, P.; Atkins, H.L.

    1975-01-01

    Methodology and instrumentation are being developed to measure distal airway closure, a very sensitive diagnostic technique for the early detection of emphysema and other obstructive lung diseases and premature closure indicating abnormalities. The procedure is rapid and involves the inhalation of only a 1 ml bolus of readily available stable 4 He, continuous measurement of its concentration in the exhaled air with a helium leak detector type of mass spectrometer, and the subsequent analysis of the single-breath washout curve. Helium appears to be an ideal tracer, well-suited for testing in clinics and hospitals, as well as for epidemiological studies relating the effects of atmospheric pollutants and lung impairment and for screening of large populations for pulmonary dysfunction

  7. Normal mediastinal and hilar lymph nodes evaluated by 5 mm slice bolus injection CT scan

    International Nuclear Information System (INIS)

    Yamamoto, Takako; Tsukada, Hiroshi; Koizumi, Naoya; Akita, Shinichi; Oda, Junichi; Sakai, Kunio

    1995-01-01

    We evaluated the number and size of normal mediastinal and hilar lymph nodes by 5 mm slice bolus injection CT (12 patients), compared with 10 mm slice CT (12 patients). More lymph nodes were clearly demonstrated by 5 mm slice CT than by 10 mm slice CT. Especially left-sided tracheobronchial (no.4), subaortic (no.5), subcarinal (no.7) and hilar lymph nodes were clearly visible. We concluded 5 mm slice bolus injection CT was useful to evaluate mediastinal and hilar lymph nodes. (author)

  8. Use of cornmeal bolus as an aid in obtaining cranial four-vessel angiograms.

    Science.gov (United States)

    Weathers, R M; Lee, A

    1975-01-01

    In cranial angiography it has always been difficult to visualize extracranial vessels of the cervico-thoracic region, upon one radiograph, by using the same exposure factors for both regions. For this reason, we experimented and found that by applying a dry cornmeal bolus on specific areas of the neck a technically superior radiograph of these regions can be achieved. This bolus simulated added soft tissue to the cervical region. The density of the cervical region is now similar to that of the upper thoracic. As a result, factors set for one exposure will adequately penetrate both areas.

  9. Comparison of Insulin Detemir and Insulin Glargine for Hospitalized Patients on a Basal-Bolus Protocol

    Directory of Open Access Journals (Sweden)

    Sondra Davis

    2017-04-01

    Full Text Available BACKGROUND: The primary purpose of this study is to determine whether insulin detemir is equivalent to insulin glargine in controlling hyperglycemia for the adult hospitalized patient on a basal-bolus treatment regimen. METHODS: A retrospective study was conducted at two acute care hospitals within the same health system. Patients from both facilities who were initiated on a basal-bolus subcutaneous insulin regimen were included in the study. The basal-bolus regimen consisted of three components: basal, bolus, and corrective insulin with only the data from the first seven days analyzed. Once the basal-bolus protocol was initiated, all previous glycemic agents were discontinued. The target glycemic goal of the study was 100–180 mg/dL. RESULTS: In both groups, 50% of the patients had achieved the target glycemic control goal (100–180 mg/dL by day 2 (p = 0.3. However, on the seventh or last day of basal-bolus treatment, whichever came first, 36.36% of patients receiving insulin detemir (n = 88 achieved the blood glucose reading goal compared to 52.00% in patients receiving insulin glargine (n = 100 (p = 0.03. This corresponded to an adjusted odds ratio of 2.12 (1.08 to 4.15, p = 0.03. The adjusting variables were provider type, whether the patient was hospitalized within 30 days prior and diagnosis of stroke. The mean blood glucose readings for the insulin glargine and the insulin detemir groups while on basal-bolus therapy were 200 mg/dL and 215 mg/dL, respectively (p = 0.05. The total number of blood glucose readings less than 70 mg/dL and less than 45 mg/dL was very low and there were no differences in number of episodes with hypoglycemia between the two groups. CONCLUSION: There was not a statistical difference between the two groups at 2 days, however there was on the seventh day or the last day of basal-bolus treatment. There were nonsignificant hypoglycemia events between basal insulin groups and the results for the last or seventh day

  10. Commentary on "Performance of a glucose meter with a built-in automated bolus calculator versus manual bolus calculation in insulin-using subjects".

    Science.gov (United States)

    Rossetti, Paolo; Vehí, Josep; Revert, Ana; Calm, Remei; Bondia, Jorge

    2012-03-01

    Since the early 2000s, there has been an exponentially increasing development of new diabetes-applied technology, such as continuous glucose monitoring, bolus calculators, and "smart" pumps, with the expectation of partially overcoming clinical inertia and low patient compliance. However, its long-term efficacy in glucose control has not been unequivocally proven. In this issue of Journal of Diabetes Science and Technology, Sussman and colleagues evaluated a tool for the calculation of the prandial insulin dose. A total of 205 insulin-treated patients were asked to compute a bolus dose in two simulated conditions either manually or with the bolus calculator built into the FreeStyle InsuLinx meter, revealing the high frequency of wrong calculations when performed manually. Although the clinical impact of this study is limited, it highlights the potential implications of low diabetesrelated numeracy in poor glycemic control. Educational programs aiming to increase patients' empowerment and caregivers' knowledge are needed in order to get full benefit of the technology. © 2012 Diabetes Technology Society.

  11. The use of 123I-labeled heptadecanoic acid (HDA) as metabolitic tracer

    International Nuclear Information System (INIS)

    Dudczak, R.; Kletter, K.; Frischauf, H.; Schmoliner, R.; Losert, U.; Angelberger, P.

    1984-01-01

    The feasibility of using 123 I-heptadecanoic acid (HDA) as a metabolic tracer was studied. Different administration routes of HDA were compared. An intracoronary bolus injection was given to calves (n=3), and an intravenous injection was given to patients (n=4). In addition, we examined the influence of 4-h halothane anesthesia in calves and in patients the impact of an isulin (1.5 IU/kg)+glucose (1.5 g/kg) infusion on the myocardial kinetics of HDA. Data were accumulated with a scintillation probe in calves (t=50 min) and a gamma camera in patients (t=70 min). In calves after an intracoronary bolus injection of HDA the myocardial time-activity curve could be described by two exponentials. The mean elimination half-time of the initial phase (tsub(a) 1/2) was 7.3 min and that of the second phase (tsub(b) 1/2) was 35 min. The ratio of the size of the initial and second component at t 0 was 0.93. Halothane anesthesia prolonged the elimination half-times and reduced the component ratio. The biphasic behavior of the myocardial time-activity curve was maintained in patients after intravenous administration of HDA under basal conditions (inital tsub(a) 1/2=8.4 min). However, during infusion of insulin+glucose the decline in the myocardial activity was prolonged and monoexponential. This data show that insulin glucose, interfering with fatty acid metabolism, influences the myocardial washout of HDA, and thus support it use as a metabolic tracer. (orig.)

  12. The use of 123I-labeled heptadecanoic acid (HDA) as metabolic tracer: preliminary report.

    Science.gov (United States)

    Dudczak, R; Kletter, K; Frischauf, H; Losert, U; Angelberger, P; Schmoliner, R

    1984-01-01

    The feasibility of using 123I-heptadecanoic acid (HDA) as a metabolic tracer was studied. Different administration routes of HDA were compared. An intracoronary bolus injection was given to calves (n = 3), and an intravenous injection was given to patients (n = 4). In addition, we examined the influence of 4-h halothane anesthesia in calves and in patients the impact of an insulin (1.5 IU/kg) + glucose (1.5 g/kg) infusion on the myocardial kinetics of HDA. Data were accumulated with a scintillation probe in calves (t = 50 min) and a gamma camera in patients (t = 70 min). In calves after an intracoronary bolus injection of HDA the myocardial time-activity curve could be described by two exponentials. The mean elimination half-time of the initial phase (ta 1/2) was 7.3 min and that of the second phase (tb 1/2) was 35 min. The ratio of the size of the initial and second component at to was 0.93. Halothane anesthesia prolonged the elimination half-times and reduced the component ratio. The biphasic behavior of the myocardial time-activity curve was maintained in patients after intravenous administration of HDA under basal conditions (initial ta 1/2 = 8.4 min). However, during infusion of insulin + glucose the decline in the myocardial activity was prolonged and monoexponential. This data shows that insulin glucose, interfering with fatty acid metabolism, influences the myocardial washout of HDA, and thus support its use as a metabolic tracer.

  13. Fish Passage Center 2001 annual report.; ANNUAL

    International Nuclear Information System (INIS)

    Fish Passage Center

    2002-01-01

    Extremely poor water conditions within the Columbia River Basin along with extraordinary power market conditions created an exceptionally poor migration year for juvenile salmon and steelhead. Monthly 2001 precipitation at the Columbia above Grand Coulee, the Snake River above Ice Harbor, and the Columbia River above The Dalles was approximately 70% of average. As a result the 2001 January-July runoff volume at The Dalles was the second lowest in Columbia River recorded history. As a compounding factor to the near record low flows in 2001, California energy deregulation and the resulting volatile power market created a financial crisis for the Bonneville Power Administration (BPA). Power emergencies were first declared in the summer and winter of 2000 for brief periods of time. In February of 2001, and on April 3, the BPA declared a ''power emergency'' and suspended many of the Endangered Species Act (ESA) and Biological Opinion (Opinion) measures that addressed mainstem Columbia and Snake Rivers juvenile fish passage. The river and reservoir system was operated primarily for power generation. Power generation requirements in January through March coincidentally provided emergence and rearing flows for the Ives-Pierce Islands spawning area below Bonneville Dam. In particular, flow and spill measures to protect juvenile downstream migrant salmon and steelhead were nearly totally suspended. Spring and summer flows were below the Opinion migration target at all sites. Maximum smolt transportation was implemented instead of the Opinion in-river juvenile passage measures. On May 16, the BPA Administrator decided to implement a limited spill for fish passage at Bonneville and The Dalles dams. On May 25, a limited spill program was added at McNary and John Day dams. Spill extended to July 15. Juvenile migrants, which passed McNary Dam after May 21, experienced a noticeable, improved survival, as a benefit of spill at John Day Dam. The suspension of Biological Opinion

  14. The European tracer experiment ETEX: a real-time long range atmospheric dispersion model exercise in different weather conditions

    International Nuclear Information System (INIS)

    Graziani, G.; )

    1998-01-01

    Two long-range tracer experiments were conducted. An inert, non-depositing tracer was being released at Rennes in France for 12 hours. The 168 sampling ground stations were run by the National Meteorological Services. Twenty-four institutions took part in the real-time forecasting of the cloud evolution using 28 long-range dispersion models. The horizontal projection of the cloud evolution over Europe was combined with real-time aerial chemical analysis. The results of the comparison indicate that a limited group of models (7-8) were capable of obtaining a good reproduction of the cloud movement throughout Europe for the first release. Large differences were, however, found in the predicted tracer concentration at a particular location. For the second release, there were large differences between the measured and calculated cloud, particularly after a front passage, which indicates that some efforts have still to be spent before consensus on the model reliability is achieved. (P.A.)

  15. Doublet Tracer Testing in Klamath Falls, Oregon

    Energy Technology Data Exchange (ETDEWEB)

    Gudmundsson, J.S.; Johnson, S.E.; Horne, R.N.; Jackson, P. B. [Pet. Eng. Dept., Stanford University; Culver, G.G. [Geo-Heat Center, Oregon Institute of Technology, Klamath Falls, OR

    0001-01-01

    A tracer test was carried out in a geothermal doublet system to study the injection behavior of a developed reservoir known to be fractured. The doublet produces about 320 gpm of 160 degrees Fahrenheit water that is used for space heating and then injected; the wells are spaced 250 ft apart. Tracer breakthrough was observed in 2 hours and 45 minutes in the production well, indicating fracture flow. However, the tracer concentrations were low and indicated porous media flow; the tracers mixed with a reservoir volume much larger than a fracture.

  16. Doublet Tracer Testing in Klamath Falls, Oregon

    Energy Technology Data Exchange (ETDEWEB)

    Gudmundsson, J S; Johnson, S E; Horne, R N; Jackson, P B [Pet. Eng. Dept., Stanford University; Culver, G G [Geo-Heat Center, Oregon Institute of Technology, Klamath Falls, OR

    0000-12-30

    A tracer test was carried out in a geothermal doublet system to study the injection behavior of a developed reservoir known to be fractured. The doublet produces about 320 gpm of 160 degrees Fahrenheit water that is used for space heating and then injected; the wells are spaced 250 ft apart. Tracer breakthrough was observed in 2 hours and 45 minutes in the production well, indicating fracture flow. However, the tracer concentrations were low and indicated porous media flow; the tracers mixed with a reservoir volume much larger than a fracture.

  17. Tracer a application in marine outfall studies

    International Nuclear Information System (INIS)

    Genders, S.

    1979-01-01

    The applicability of radioactive and fluorescent tracers for field studies to predict or investigate waste water transport and dispersion from marine outfalls is evaluated. The application of either instantaneous or continuous tracer release, 'in situ' detection of tracers and data processing are considered. The necessity of a combined use of tracer techniques and conventional hydrographic methods for a statistical prediction of transport and dillution of waste water are pointed out. A procedure to determine an outlet distance from the coast, which satisfy bathing water criteria is outlined. (M.A.) [pt

  18. Principles and techniques of gamma ray tracers

    International Nuclear Information System (INIS)

    Claxton, K.T.

    1978-01-01

    Radioactive tracer techniques provide a very sensitive means of studying physical and chemical processes in a whole variety of different media. Some of the techniques and principles of radioactive tracers and their application to practical engineering systems are discussed. Information which has been found useful in the design of high temperature liquid sodium facilities employing radio-tracers, is presented. The report deals solely with the use of gamma-emitting species as the tracer. These find particular application for in-situ studies on engineering systems where the highly penetrating properties of gamma rays are needed for detection through strongly absorbent media such as stainless steel pepe walls. (author)

  19. Use of artificial tracers in hydrology

    International Nuclear Information System (INIS)

    1991-05-01

    The IAEA has convened an Advisory Group Meeting with the following objectives: To define the role of artificial radioactive tracers for water tracing in comparison with other non-radioactive tracers. To evaluate the real needs of artificial radioactive tracers in hydrology. To identify the fields for which artificial radioactive tracers are useful as well as those in which they can be substituted by other tracers. To discuss the strategy to be adopted to overcome the difficulties derived from the restrictions on the use of radioactive tracers in hydrology. The meeting was held at IAEA Headquarters from 19 to 22 March 1990, and was attended by 30 participants from 15 Member States. The conclusions and recommendations are that the use of artificial radioactive tracers should be restricted to cases where other tracers cannot be used or do not provide the same quality of information. Tritium, iodine-131, bromine-82, chromium-51 in the form of Cr-EDTA, technetium-99m obtained from 99 Mo-generators and gold-198 as an adsorbable tracer are, practically, the only radionuclides used for water tracing. The use of other radionuclides for this purpose does not appear to be necessary, possible and/or convenient. Refs, figs and tabs

  20. Quadratic tracer dynamical models tobacco growth

    International Nuclear Information System (INIS)

    Qiang Jiyi; Hua Cuncai; Wang Shaohua

    2011-01-01

    In order to study the non-uniformly transferring process of some tracer dosages, we assume that the absorption of some tracer by tobacco is a quadratic function of the tracer quantity of the tracer in the case of fast absorption, whereas the exclusion of the tracer from tobacco is a linear function of the tracer quantity in the case of slow exclusion, after the tracer is introduced into tobacco once at zero time. A single-compartment quadratic dynamical model of Logistic type is established for the leaves of tobacco. Then, a two-compartment quadratic dynamical model is established for leaves and calms of the tobacco. Qualitative analysis of the models shows that the tracer applied to the leaves of the tobacco is excluded finally; however, the tracer stays at the tobacco for finite time. Two methods are also given for computing the parameters in the models. Finally, the results of the models are verified by the 32 P experiment for the absorption of tobacco. (authors)

  1. Review article : intra-oesophageal impedance monitoring for the assessment of bolus transit and gastro-oesophageal reflux

    NARCIS (Netherlands)

    Conchillo, J. M.; Smout, A. J.

    2009-01-01

    Background Intra-oesophageal impedance monitoring can be used to assess the clearance of a swallowed bolus (oesophageal transit) and to detect gastro-oesophageal reflux independent of its acidity. Aim To discuss the clinical application of the impedance technique for the assessment of bolus transit

  2. Continuous indomethacin infusion may be less effective than bolus infusions for ductal closure in very low birth weight infants

    NARCIS (Netherlands)

    de Vries, NKS; Jagroep, FK; Jaarsma, AS; Elzenga, NJ; Bos, AF

    The effectiveness of continuous indomethacin (INDO) infusion versus bolus infusions for closure of patent ductus arteriosus (PDA) was investigated. The study design was an open-label case series (continuous INDO) with historic controls matched for gestational age (bolus INDO). Ductal closure rates

  3. Evaluation of a Water-based Bolus Device for Radiotherapy to the Extremities in Kaposi's Sarcoma Patients

    International Nuclear Information System (INIS)

    Ahn, Seung Kwon; Kim, Yong Bae; Lee, Ik Jae

    2008-01-01

    We designed a water-based bolus device for radiation therapy in Kaposi's sarcoma. This study evaluated the usefulness of this new device and compared it with the currently used rice-based bolus. Materials and Methods: We fashioned a polystyrene box and cut a hole in order to insert patient's extremities while the patient was in the supine position. We used a vacuum-vinyl based polymer to reduce water leakage. Next, we eliminated air using a vacuum pump and a vacuum valve to reduce the air gap between the water and extremities in the vacuum-vinyl box. We performed CT scans to evaluate the density difference of the fabricated water-based bolus device when the device in which the rice-based bolus was placed directly, the rice-based bolus with polymer-vinyl packed rice, and the water were all put in. We analyzed the density change with the air gap volume using a planning system. In addition, we measured the homogeneity and dose in the low-extremities phantom, attached to six TLD, and wrapped film exposed in parallel-opposite fields with the LINAC under the same conditions as the set-up of the CT-simulator. Results: The density value of the rice-based bolus with the rice put in directly was 14% lower than that of the water-based bolus. Moreover, the value of the other experiments in the rice-based bolus with the polymer-vinyl packed rice showed an 18% reduction in density. The analysis of the EDR2 film revealed that the water-based bolus shows a more homogeneous dose plan, which was superior by 4.0-4.4% to the rice-base bolus. The mean TLD readings of the rice-based bolus, with the rice put directly into the polystyrene box had a 3.4% higher density value. Moreover, the density value in the case of the rice-based bolus with polymer-vinyl packed rice had a 4.3% higher reading compared to the water-based bolus. Conclusion: Our custom-made water-based bolus device increases the accuracy of the set-up by confirming the treatment field. It also improves the accuracy of the

  4. Gender Differences in Implicit and Explicit Memory for Affective Passages

    Science.gov (United States)

    Burton, Leslie A.; Rabin, Laura; Vardy, Susan Bernstein.; Frohlich, Jonathan; Wyatt, Gwinne; Dimitri, Diana; Constante, Shimon; Guterman, Elan

    2004-01-01

    Thirty-two participants were administered 4 verbal tasks, an Implicit Affective Task, an Implicit Neutral Task, an Explicit Affective Task, and an Explicit Neutral Task. For the Implicit Tasks, participants were timed while reading passages aloud as quickly as possible, but not so quickly that they did not understand. A target verbal passage was…

  5. Teleportation of an Unknown Atomic State via Adiabatic Passage

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    We propose a scheme for teleporting an unknown atomic state via adiabatic passage. Taking advantage of adiabatic passage, the atom has no probability of being excited and thus the atomic spontaneous emission is suppressed.We also show that the fidelity can reach 1 under certain condition.

  6. Unfrozen sea : sailing the northwest passage

    International Nuclear Information System (INIS)

    Byers, M.

    2007-01-01

    This article described the author's journey into the Canadian Arctic that documented the shrinking sea of Canada's Arctic region. It emphasized the loss of ecosystem and animal habitat. It addressed issues regarding Canada's claims of Arctic sovereignty over disputed waters, such as the Northwest Passage. In March 2006, the area covered during the winter by sea-ice was at an all-time low, namely 300,000 square kilometres less than the previous year. At this rate the Arctic could lose all of its sea-ice by 2030. The article also discussed phytoplankton in the Arctic which, removes carbon dioxide from the atmosphere by photosynthesis. Since the waters they live in are so cold, the phytoplankton sink into the ocean depths when they die, without decomposing. The carbon they removed from the atmosphere remains at the bottom of the sea for hundreds of years. However, as water warms up, the activity of marine bacteria that feed on the dead plankton will increase, releasing carbon dioxide back into the atmosphere. Issues related to international shipping, navigation, ownership of Arctic islands, military presence and boats in the northern channels, and political promises with respect to the Canadian Coast Guard and northern waterways were also discussed. 1 fig

  7. 50 years of first-passage percolation

    CERN Document Server

    Auffinger, Antonio; Hanson, Jack

    2017-01-01

    First-passage percolation (FPP) is a fundamental model in probability theory that has a wide range of applications to other scientific areas (growth and infection in biology, optimization in computer science, disordered media in physics), as well as other areas of mathematics, including analysis and geometry. FPP was introduced in the 1960s as a random metric space. Although it is simple to define, and despite years of work by leading researchers, many of its central problems remain unsolved. In this book, the authors describe the main results of FPP, with two purposes in mind. First, they give self-contained proofs of seminal results obtained until the 1990s on limit shapes and geodesics. Second, they discuss recent perspectives and directions including (1) tools from metric geometry, (2) applications of concentration of measure, and (3) related growth and competition models. The authors also provide a collection of old and new open questions. This book is intended as a textbook for a graduate course or as a...

  8. Upstream Atlantic salmon (Salmo salar) passage

    International Nuclear Information System (INIS)

    Clay, C.H.

    1993-01-01

    Upstream salmon passage though a dam is discussed with respect to three main components: the fishway entrance, the fishway, and the exit. Design considerations and alternative types of components are presented. For fishway entrances, an important consideration is the positioning of the entrance as far upstream as the fish can swim with respect to obstacles. For powerhouses using water diverted from a river, the problem of leading fish past the powerhouse may be overcome by either installing a tailrace barrier or increasing the flow until the home stream odor is sufficient to attract fish. Swimming ability should be the first consideration in fishway design. Fishways with 50 cm drops per pool would be satisfactory in most cases. The problem of headwater fluctuation is overcome through careful fishway selection. Fish locks, hoists, and elevators are other alternatives to pool/weir fishways. The location for a fish exit must be decided on the basis of whether the fishway will be used only for upstream migrations. 5 refs., 1 fig., 1 tab

  9. Adductor Canal Block With Continuous Infusion Versus Intermittent Boluses and Morphine Consumption

    DEFF Research Database (Denmark)

    Jaeger, Pia; Baggesgaard, Jonas; Sørensen, Johan K

    2018-01-01

    a randomized, blinded, controlled study, including patients scheduled for total knee arthroplasty with spinal anesthesia. Patients received 0.2% ropivacaine via a catheter in the adductor canal administered as either repeated intermittent boluses (21 mL/3 h) or continuous infusion (7 mL/h). The primary outcome...

  10. Dual-phase helical CT using bolus triggering technique: optimization of transition time

    International Nuclear Information System (INIS)

    Choi, Young Ho; Kim, Tae Kyoung; Park, Byung Kwan; Koh, Young Hwan; Han, Joon Koo; Choi, Byung Ihn

    1999-01-01

    To optimize the transition time between the triggering point in monitoring scanning and the initiation of diagnostic hepatic arterial phase (HAP) scanning in hepatic spiral CT, using a bolus triggering technique. One hundred consecutive patients with focal hepatic lesion were included in this study. Patients were randomized into two groups. Transition times of 7 and 11 seconds were used in group 1 and 2, respectively. In all patients, bolus triggered HAP spiral CT was obtained using a semi-automatic bolus tracking program after the injection of 120mL of non-ionic contrast media at a rate of 3mL/sec. When aortic enhancement reached 90 HU, diagnostic HAP scanning began after a given transition time. From images of group 1 and group 2, the degree of parenchymal enhancement of the liver and tumor-to-liver attenuation difference were measured. Also, for qualitative analysis, conspicuity of the hepatic artery and hypervascular tumor was scored and analyzed. Hepatic parenchymal enhancement on HAP was 12.07 + /-6.44 HU in group 1 and 16.03 + /-5.80 HU in group 2 (p .05). In the evaluation of conspicuity of hepatic artery, there was no statistically significant difference between the two groups (p > .05). The conspicuity of hypervascular tumors in group 2 was higher than in group 1 (p < .05). HAP spiral CT using a bolus triggering technique with a transition time of 11 seconds provides better HAP images than when the transition time is 7 seconds

  11. Precision flow-controlled rubidium-82 generator for bolus and constant infusion studies

    International Nuclear Information System (INIS)

    Yano, Y.

    1981-01-01

    A unique flow rate controller and large reservoir pumping system have been developed for infusing rubidium-82 intravenously at bolus, constant, or variable infusion rates. Using rubidium-82 and the positron ring detector tomograph, extraction or flow information can be obtained in studies of the heart, head, or kidneys

  12. Split bolus technique in polytrauma: a prospective study on scan protocols for trauma analysis

    NARCIS (Netherlands)

    Beenen, Ludo F. M.; Sierink, Joanne C.; Kolkman, Saskia; Nio, C. Yung; Saltzherr, Teun Peter; Dijkgraaf, Marcel G. W.; Goslings, J. Carel

    2015-01-01

    For the evaluation of severely injured trauma patients a variety of total body computed tomography (CT) scanning protocols exist. Frequently multiple pass protocols are used. A split bolus contrast protocol can reduce the number of passes through the body, and thereby radiation exposure, in this

  13. The effect of food bolus location on jaw movement smoothness and masticatory efficiency

    NARCIS (Netherlands)

    Molenaar, W.N.B.; Gezelle Meerburg, P.J.; Luraschi, J.; Whittle, T.; Schimmel, M.; Lobbezoo, F.; Peck, C.C.; Murray, G.M.; Minami, I.

    2012-01-01

    Masticatory efficiency in individuals with extensive tooth loss has been widely discussed. However, little is known about jaw movement smoothness during chewing and the effect of differences in food bolus location on movement smoothness and masticatory efficiency. The aim of this study was to

  14. Use of a marshmallow bolus for evaluating lower esophageal mucosal rings.

    Science.gov (United States)

    Ott, D J; Kelley, T F; Chen, M Y; Gelfand, D W; Wu, W C

    1991-07-01

    Sixty-three patients (35 women, 28 men; mean age 55 yr) with lower esophageal mucosal ring shown radiographically were examined with a semi-solid bolus consisting of a portion of a standard marshmallow. The most common symptom was dysphagia, present in 46 (73%) patients. Impaction of the marshmallow bolus by the ring occurred in 40 (63%) of the 63 patients, and produced symptoms in 27 (68%) of these 40 patients. Nine (14%) rings were detected radiographically only with a solid bolus; eight of these patients had dysphagia and seven rings were 20 mm or less in caliber. Impaction related to ring caliber, and was found in all 17 (100%) rings that were 13 mm or less in diameter, in 17/24 (71%) 14- to 19-mm rings, and in 6/22 (27%) rings 20 mm or more in caliber. Endoscopy in 23 patients detected 16 (70%) rings, and also depended on ring caliber: less than or equal to 13 mm, 6/6 (100%); 14-19 mm, 5/9 (56%); greater than or equal to 20 mm, 5/8 (63%). Marshmallow impaction occurred in 17 (74%) of 23 patients who had endoscopy; three of the 23 patients had normal endoscopy. In conclusion, radiographic examination supplemented by the use of a marshmallow bolus best detects lower esophageal mucosal ring.

  15. Pharmacokinetics of rocuronium after bolus and continuous infusion during halothane anaesthesia

    NARCIS (Netherlands)

    McCoy, E.P; Mirakhur, R.K; Maddineni, V.R; Wierda, J.MKH; Proost, Hans

    We have studied the pharmacokinetics of a single bolus of rocuronium (Org 9426), followed by an infusion, in eight patients during anaesthesia with halothane and nitrous oxide in oxygen. Neuromuscular block was monitored using train-of-four (TOF) stimulation and recording the force of contraction of

  16. Tolerance to continuous intrathecal baclofen infusion can be reversed by pulsatile bolus infusion

    NARCIS (Netherlands)

    Heetla, H. W.; Staal, M. J.; van Laar, T.

    Study design: Pilot study. Objective: To study the effect of pulsatile bolus infusion of intrathecal baclofen (ITB) on daily ITB dose, in patients showing dose increases, probably due to tolerance. Setting: Department of neurology and neurosurgery, University Medical Center Groningen, the

  17. Use of an automated bolus calculator in MDI-treated type 1 diabetes

    DEFF Research Database (Denmark)

    Schmidt, Signe; Meldgaard, Merete; Serifovski, Nermin

    2012-01-01

    To investigate the effect of flexible intensive insulin therapy (FIIT) and an automated bolus calculator (ABC) in a Danish type 1 diabetes population treated with multiple daily injections. Furthermore, to test the feasibility of teaching FIIT in a 3-h structured course....

  18. Soft-robotic esophageal swallowing as a clinically-inspired bolus rheometry technique

    International Nuclear Information System (INIS)

    Dirven, Steven; Allen, Jacqueline; Xu, Weiliang; Cheng, Leo K

    2017-01-01

    To investigate the impact of viscosity and peristaltic transport parameters on manometric pressure signatures, a reproducible swallowing process is required. Due to inter- and intra-subject variability from swallow to swallow, the human body does not represent an optimal mechanism for such an investigation. A smooth and continuous swallowing soft-robot has been developed to produce biomimetic swallowing trajectories, and is proposed to operate as a bench-top bolus rheometric investigation method. The method compares conventional viscometry and pressure signature findings from robotic swallowing experiments. The robotic aspect of experimentation involved 450 biomimetic swallows (10 repetitions of 45 unique experiments). The method examined swallowing transport in three dimensions: bolus formulation, peristaltic wavelength, and peristaltic velocity, each of which are known to contribute to safe and effective swallowing in vivo . It is found that the pressure gradients and magnitudes are commensurate with clinical reports on biological swallowing, on the order of 100 mmHg peak, however, the relationship between viscosity and pressure signatures is less clear. Bolus transport cannot be predicted as a function of bolus viscosity alone. Traditional viscometric data at 50 s −1 , as used in clinical practice, may not be a strong indicator of swallow effort, safety, or efficacy in vivo . (paper)

  19. Continuous transversus abdominis plane block vs intermittent bolus for analgesia after abdominal surgery: a randomized trial

    Directory of Open Access Journals (Sweden)

    Rao Kadam V

    2017-07-01

    Full Text Available Vasanth Rao Kadam,1 Roelof M Van Wijk,1 John L Moran,2 Shantan Ganesh,3 A Kumar,1 Rajesh Sethi,1 Patricia Williams2,4 1Department of Anaesthesia, The Queen Elizabeth Hospital, School of Medicine, University of Adelaide, Adelaide, SA, 2Intensive Care Unit, The Queen Elizabeth Hospital, School of Medicine, University of Adelaide, Adelaide, SA, 3Department of Surgery, The Queen Elizabeth Hospital, School of Medicine, University of Adelaide, Adelaide, SA, 4Department of Epidemiology and Preventive Medicine, School Public Health and Preventive Medicine, Australian and New Zealand Intensive Care Research Centre, Monash University, Melbourne, VIC, Australia Background: Continuous and intermittent bolus techniques of transversus abdominis plane (TAP blocks have been used for analgesia after abdominal surgery. Although both are effective, there are no studies comparing them. The aim of this study is to compare analgesia and cost-effectiveness between these groups.Methods: After obtaining ethical approval, 20 American Society of Anesthesiologists ASA grade I to III patients undergoing elective abdominal surgery were recruited with 10 patients allocated to each arm. Bilateral ultrasound-guided TAP blocks were performed with an initial bolus of 0.5% ropivacaine 20 mL per side, followed by catheter insertion. After surgery, the continuous infusion group received 0.2% ropivacaine 8 mL/hour on each side and the intermittent bolus group received doses of 0.2% ropivacaine 20 mL per side every 8 hours for 48 hours. Both groups received intravenous fentanyl patient-controlled analgesia and regular oral paracetamol. Parameters recorded included numerical rating scores for pain and post-operative analgesic consumption at baseline (time 0 and at 1 hour, 1 day and 2 days post-operatively. The duration of catheter insertion, complications, patient satisfaction and information regarding costs were also recorded. Patient satisfaction was assessed utilizing a 4-point

  20. Comparison of first-pass and second-bolus dynamic susceptibility perfusion MRI in brain tumors

    International Nuclear Information System (INIS)

    Spampinato, M.V.; Besenski, Nada; Rumboldt, Zoran; Wooten, Caroline; Dorlon, Margaret

    2006-01-01

    Our goal was to evaluate whether the T1 shortening effect caused by contrast leakage into brain tumors, a well-known confounding effect in the quantification of relative cerebral blood volume (rCBV) measurements, may be corrected by the administration of a predose of gadolinium-DTPA. As part of their presurgical imaging protocol, 25 patients with primary brain tumors underwent two consecutive dynamic susceptibility-weighted contrast-enhanced (DSC) perfusion MR studies. Intratumoral rCBV measurements and normalized rCBV values obtained during the first-pass and second-bolus studies were compared (Wilcoxon signed-ranks test). The frequency of relatively increased rCBV ratios on the second-bolus study was compared between enhancing and non-enhancing neoplasms (Fisher's exact test). Postprocessing perfusion studies were evaluated for image quality on a scale of 0-3 (Wilcoxon signed-ranks test). Four studies were excluded due to unacceptable image quality. Mean normalized rCBVs were 9.04 (SD 4.64) for the first-pass and 7.99 (SD 3.84) for the second-bolus study. There was no statistically significant difference between the two perfusion studies in either intratumoral rCBV (P=0.237) or rCBV ratio (P=0.181). Five enhancing and four non-enhancing tumors showed a relative increase in rCBV ratio on the second-bolus study, without a significant difference between the groups. Image quality was not significantly different between perfusion studies. Our results did not demonstrate a significant difference between first-pass and second-bolus rCBV measurements in DSC perfusion MR imaging. The administration of a predose of gadolinium-DTPA does not appear to be an efficient way of compensating for the underestimation of intratumoral rCBV values due to the T1 shortening effect. (orig.)

  1. Nanoparticle tracers in calcium carbonate porous media

    KAUST Repository

    Li, Yan Vivian; Cathles, Lawrence M.; Archer, Lynden A.

    2014-01-01

    the fractures or channels where flow occurs and thus take much less time to travel between two points. In combination with a chemical tracer they can measure the degree of flow concentration. A prerequisite for tracer applications is that the particles

  2. Tracer filamentation at an unstable ocean front

    Science.gov (United States)

    Feng, Yen Chia; Mahadevan, Amala; Thiffeault, Jean-Luc; Yecko, Philip

    2017-11-01

    A front, where two bodies of ocean water with different physical properties meet, can become unstable and lead to a flow with high strain rate and vorticity. Phytoplankton and other oceanic tracers are stirred into filaments by such flow fields, as can often be seen in satellite imagery. The stretching and folding of a tracer by a two-dimensional flow field has been well studied. In the ocean, however, the vertical shear of horizontal velocity is typically two orders of magnitude larger than the horizontal velocity gradient. Theoretical calculations show that vertical shear alters the way in which horizontal strain affects the tracer, resulting in thin, sloping structures in the tracer field. Using a non-hydrostatic ocean model of an unstable ocean front, we simulate tracer filamentation to identify the effect of vertical shear on the deformation of the tracer. In a complementary laboratory experiment, we generate a simple, vertically sheared strain flow and use dye and particle image velocimetry to quantify the filamentary structures in terms of the strain and shear. We identify how vertical shear alters the tracer filaments and infer how the evolution of tracers in the ocean will differ from the idealized two-dimensional paradigm. Support of NSF DMS-1418956 is acknowledged.

  3. Dynamic dual-tracer PET reconstruction.

    Science.gov (United States)

    Gao, Fei; Liu, Huafeng; Jian, Yiqiang; Shi, Pengcheng

    2009-01-01

    Although of important medical implications, simultaneous dual-tracer positron emission tomography reconstruction remains a challenging problem, primarily because the photon measurements from dual tracers are overlapped. In this paper, we propose a simultaneous dynamic dual-tracer reconstruction of tissue activity maps based on guidance from tracer kinetics. The dual-tracer reconstruction problem is formulated in a state-space representation, where parallel compartment models serve as continuous-time system equation describing the tracer kinetic processes of dual tracers, and the imaging data is expressed as discrete sampling of the system states in measurement equation. The image reconstruction problem has therefore become a state estimation problem in a continuous-discrete hybrid paradigm, and H infinity filtering is adopted as the estimation strategy. As H infinity filtering makes no assumptions on the system and measurement statistics, robust reconstruction results can be obtained for the dual-tracer PET imaging system where the statistical properties of measurement data and system uncertainty are not available a priori, even when there are disturbances in the kinetic parameters. Experimental results on digital phantoms, Monte Carlo simulations and physical phantoms have demonstrated the superior performance.

  4. Tracer diffusion in ternary alloys

    International Nuclear Information System (INIS)

    Tahir-Kheli, R.A.

    1985-07-01

    An intuitive extension of the theory for diffusion in dynamic binary alloys given in the preceding paper is presented. This theory has also received an independent derivation, based on more formal procedures, by Holdsworth and Elliott. We present Monte Carlo estimates for diffusion correlation factors, fsup(A), fsup(B), and fsup(C) and compare them with the theory. The agreement between the theoretical results and the Monte Carlo estimates for the correlation factors of the slow particles, i.e., fsup(C) and fsup(B), is found to be generally good. In contrast, for the correlation factor, fsup(A), referring to the diffusion coefficient of fast particles in the system, the theoretical results are found to be systematically lower by a small but resolvable margin. It is suggested that this is occasioned by the neglect of spatial constraints on the scattering of coupled tracer-background particle field pairs. (author)

  5. Transuranic and tracer simulant resuspension

    International Nuclear Information System (INIS)

    Sehmel, G.A.

    1977-07-01

    Plutonium resuspension results are summarized for experiments conducted at Rocky Flats, onsite on the Hanford reservation, and for winds blowing from offsite onto the Hanford reservation near the Prosser barricade boundary. In each case, plutonium resuspension was shown by increased airborne plutonium concentrations as a function of either wind speed or as compared to fallout levels. All measured airborne concentrations were below maximum permissible concentrations (MPC). Both plutonium and cesium concentrations on airborne soil were normalized by the quantity of airborne soil sampled. Airborne radionuclide concentrations in μCi/g were related to published values for radionuclide concentrations on surface soils. For this ratio of radionuclide concentration per gram on airborne soil divided by that for ground surface soil, there are eight orders of magnitude uncertainty from 10 -4 to 10 4 . Horizontal plutonium fluxes on airborne nonrespirable soils at all three sites were bracketed within the same three to four orders of magnitude from 10 -7 to 10 -3 μCi/(m 2 day) for plutonium-239 and 10 -8 to 10 -5 μCi/(m 2 day) for plutonium-238. These are the entire experimental base for nonrespirable airborne plutonium transport. Airborne respirable plutonium-239 concentrations increased with wind speed for a southeast wind direction coming from offsite near the Hanford reservation Prosser barricade. Airborne plutonium fluxes on nonrespirable particles had isotopic ratios, 240 Pu/ 239+240 Pu, similar to weapons grade plutonium rather than fallout plutonium. Resuspension rates were summarized for controlled inert particle tracer simulant experiments. Wind resuspension rates for tracers increased with wind speed to about the fifth power

  6. Fish Passage Center 2007 Annual Report.

    Energy Technology Data Exchange (ETDEWEB)

    DeHart, Michele [Fish Passage Center of the Columbia Basin Fish & Wildlife Authority

    2008-11-25

    and McNary dams), whereas prior to 2005 spill was terminated at these projects after the spring period. In addition, the 2007 operations agreement provided regardless of flow conditions. For the first time spill for fish passage was provided in the low flow conditions that prevailed in the Snake River throughout the spring and summer migration periods. Gas bubble trauma (GBT) monitoring continued throughout the spill period. A higher incidence of rank 1, GBT signs were observed in late arriving steelhead smolts arriving after the 95% passage date had occurred. During this time dissolved gas levels were generally below the 110% water quality standard in the forebay where fish were sampled. This occurrence was due to prolonged exposure and extended travel times due to low migration flows. The 2007 migration conditions differed from any year in the historic record. The migration conditions combined low river flows in the Snake River with spill throughout the spring and summer season. The juvenile migration characteristics observed in 2007 were unique compared to past years in that high levels of 24 hour spill for fish passage were provided in low flow conditions, and with a delayed start to the smolt transportation program a smaller proportion of the total run being transported. This resulted in relatively high spring juvenile survival despite the lower flows. The seasonal spring average flow in the Snake River was 61 Kcfs much lower than the spring time average of 120 Kcfs that occurred in 2006. However juvenile steelhead survival through the Lower Granite to McNary reach in 2007 was nearly 70% which was similar to the juvenile steelhead survival seen in 2006 under higher migration flows. The low flows in the May-July period of 2007 were similar to the 2001 low flow year, yet survival for fall chinook juveniles in this period in 2007 was much higher. In 2001 the reach survival estimate for juvenile fall Chinook from Lower Granite to McNary Dam ranged from 0

  7. Pre-pharyngeal swallow effects of recurrent laryngeal nerve lesion on bolus shape and airway protection in an infant pig model

    Science.gov (United States)

    Gould, Francois D. H.; Yglesias, B.; Ohlemacher, J.; German, R. Z.

    2016-01-01

    Recurrent laryngeal nerve (RLN) damage in infants leads to increased dysphagia and aspiration pneumonia. Recent work has shown that intra oral transport and swallow kinematics change following RLN lesion, suggesting potential changes in bolus formation prior to the swallow. In this study we used geometric morphometrics to understand the effect of bolus shape on penetration and aspiration in infants with and without RLN lesion. We hypothesized 1) that geometric bolus properties are related to airway protection outcomes and 2) that in infants with RLN lesion, the relationship between geometric bolus properties and dysphagia is changed. In five infant pigs, dysphagia in 188 swallows was assessed using the Infant Mammalian Penetration Aspiration Score (IMPAS). Using images from high-speed VFSS, bolus shape, bolus area, and tongue outline were quantified digitally. Bolus shape was analyzed using elliptical Fourier analysis, and tongue outline using polynomial curve fitting. Despite large inter-individual differences, significant within individual effects of bolus shape and bolus area on airway protection exist. The relationship between penetration-aspiration score and both bolus area and shape changed post lesion. Tongue shape differed between pre and post lesion swallows, and between swallows with different IMPAS scores. Bolus shape and area affect airway protection outcomes. RLN lesion changes that relationship, indicating that proper bolus formation and control by the tongue requires intact laryngeal sensation. The impact of RLN lesion on dysphagia is pervasive. PMID:27873091

  8. Performance of a glucose meter with a built-in automated bolus calculator versus manual bolus calculation in insulin-using subjects.

    Science.gov (United States)

    Sussman, Allen; Taylor, Elizabeth J; Patel, Mona; Ward, Jeanne; Alva, Shridhara; Lawrence, Andrew; Ng, Ronald

    2012-03-01

    Patients consider multiple parameters in adjusting prandial insulin doses for optimal glycemic control. Difficulties in calculations can lead to incorrect doses or induce patients to administer fixed doses, rely on empirical estimates, or skip boluses. A multicenter study was conducted with 205 diabetes subjects who were on multiple daily injections of rapid/ short-acting insulin. Using the formula provided, the subjects manually calculated two prandial insulin doses based on one high and one normal glucose test result, respectively. They also determined the two doses using the FreeStyle InsuLinx Blood Glucose Monitoring System, which has a built-in, automated bolus calculator. After dose determinations, the subjects completed opinion surveys. Of the 409 insulin doses manually calculated by the subjects, 256 (63%) were incorrect. Only 23 (6%) of the same 409 dose determinations were incorrect using the meter, and these errors were due to either confirmed or potential deviations from the study instructions by the subjects when determining dose with meter. In the survey, 83% of the subjects expressed more confidence in the meter-calculated doses than the manually calculated doses. Furthermore, 87% of the subjects preferred to use the meter than manual calculation to determine prandial insulin doses. Insulin-using patients made errors in more than half of the manually calculated insulin doses. Use of the automated bolus calculator in the FreeStyle InsuLinx meter minimized errors in dose determination. The patients also expressed confidence and preference for using the meter. This may increase adherence and help optimize the use of mealtime insulin. © 2012 Diabetes Technology Society.

  9. Excess bottom radon 222 distribution in deep ocean passages

    International Nuclear Information System (INIS)

    Sarmiento, J.L.; Broecker, W.S.; Biscaye, P.E.

    1978-01-01

    Radon 222 and STD profiles were obtained as part of the Geosecs program in the Vema Channel in the southwest Atlantic Ocean and in the Samoan, Clarion, and Wake Island passages in the Pacific Ocean. The standing crop of excess radon 222 is higher in the passages than at other nearby locations. The most likely explanation for this is that there is a high flux of radon 222 from the floor of the passages. Since much of the floor is covered with manganese nodules and encrustations, the high flux of radon 222 may be attributable to the high concentrations of radium 226 in the outer few millimeters of such deposits. Laboratory measurements of radon 222 emissivity from maganese encrustations obtained in Vema Channel support this hypothesis. The excess radon 222 in the Vema Channel and Wake Island Passage is found in substantial quantities at heights above bottom greatly exceeding the heights at which excess radon 222 is found in nonpassage areas. The horizontal diffusion of radon emanating from the walls of the passages is unlikely to be the cause of the observed concentrations because the ratio of wall surface area to water volume is very low. The profiles must therefore be a result of exceptionally high apparent vertical mixing in the passages. Further work is needed to determine the nature of this apparent vertical mixing. The excess radon 222 and STD data in all four passages have been fit with an empirical model in which it is assumed that the bouyancy flux is constant with distance above bottom. The fits are very good and yield apparent buoyancy fluxes that are between 1 and 3 orders of magnitude greater than those obtained at nearby stations outside the passages for three of the four passages

  10. EFFECT OF A BITTER BOLUS ON ORAL, PHARYNGEAL AND ESOPHAGEAL TRANSIT OF HEALTHY SUBJECTS

    Directory of Open Access Journals (Sweden)

    Leda Maria Tavares ALVES

    2013-03-01

    Full Text Available Context During swallowing, boluses stimulate sensory receptors of the oral, pharyngeal, laryngeal, and esophageal regions. Sweet and tasteless foods are more acceptable for swallowing than bitter foods. A bitter bolus is unpleasant for most subjects. Our hypothesis was that the ingestion of a bitter bolus might alter the oral behavior, pharyngeal and esophageal transit when compared to a sweet bolus. Objective To evaluate whether the bitter taste of a liquid bolus causes alteration on oral, pharyngeal and/or esophageal transit in normal subjects in comparison with sweet bolus.' Method Scintigraphic evaluation of oral, pharyngeal and esophageal transit was performed in 43 asymptomatic subjects, 22 women and 21 men, ages 23-71 years, without problems with the ingestion of liquid and solid foods, and without digestive, cardiac or neurologic diseases. Each subject swallowed in random sequence and at room temperature 5 mL of a liquid bolus with bitter taste, prepared with 50 mL of water with 2 g of leaves of Peumus boldus, heated until boiling (boldus tea, and 5 mL of a liquid bolus with sweet taste, prepared with 50 mL of water with 3 g of sucrose, both labeled with 37 MBq of technetium phytate (Tc99m. Results There was no difference between the bitter bolus and the sweet bolus in mouth, pharynx and esophageal transit and clearance duration and in the amount of residues. Conclusion A bitter bolus, considered an unpleasant bolus, does not alter the duration of oral, pharyngeal and esophageal phases of swallowing, when compared with a sweet bolus, considered a pleasant bolus. Contexto Durante a deglutição o bolo estimula os receptores sensoriais da boca, faringe, laringe e esôfago. Os alimentos doces e sem gosto são mais aceitáveis para a deglutição do que os alimentos amargos, que tem gosto desagradável para a maioria dos indivíduos. A hipótese destes autores era que a ingestão de um bolo amargo pode alterar o trânsito oral

  11. The relativistic titls of Giza pyramids' entrance-passages

    Science.gov (United States)

    Aboulfotouh, H.

    The tilts of Giza pyramids' entrance-passages have never been considered as if they were the result of relativistic mathematical equations, and never been thought to encode the Earth's obliquity parameters. This paper presents an attempt to retrieve the method of establishing the equations that the pyramids' designer used to quantify the entrance-passages' tilts of these architectonic masterpieces. It proves that the pyramids' designer was able to include the geographic, astronomical and time parameters in one relativistic equation, encoding the date of the design of the Giza pyramids in the tilt of the entrance passage of the great pyramid.

  12. Evaluation of various boluses in dose distribution for electron therapy of the chest wall with an inward defect

    Science.gov (United States)

    Mahdavi, Hoda; Jabbari, Keyvan; Roayaei, Mahnaz

    2016-01-01

    Delivering radiotherapy to the postmastectomy chest wall can be achieved using matched electron fields. Surgical defects of the chest wall change the dose distribution of electrons. In this study, the improvement of dose homogeneity using simple, nonconformal techniques of thermoplastic bolus application on a defect is evaluated. The proposed phantom design improves the capability of film dosimetry for obtaining dose profiles of a patient's anatomical condition. A modeled electron field of a patient with a postmastectomy inward surgical defect was planned. High energy electrons were delivered to the phantom in various settings, including no bolus, a bolus that filled the inward defect (PB0), a uniform thickness bolus of 5 mm (PB1), and two 5 mm boluses (PB2). A reduction of mean doses at the base of the defect was observed by any bolus application. PB0 increased the dose at central parts of the defect, reduced hot areas at the base of steep edges, and reduced dose to the lung and heart. Thermoplastic boluses that compensate a defect (PB0) increased the homogeneity of dose in a fixed depth from the surface; adversely, PB2 increased the dose heterogeneity. This study shows that it is practical to investigate dose homogeneity profiles inside a target volume for various techniques of electron therapy. PMID:27051169

  13. Effects of a sour bolus on the intramuscular electromyographic (EMG) activity of muscles in the submental region.

    Science.gov (United States)

    Palmer, Phyllis M; McCulloch, Timothy M; Jaffe, Debra; Neel, Amy T

    2005-01-01

    A sour bolus has been used as a modality in the treatment of oropharyngeal dysphagia based on the hypothesis that this stimulus provides an effective preswallow sensory input that lowers the threshold required to trigger a pharyngeal swallow. The result is a more immediate swallow onset time. Additionally, the sour bolus may invigorate the oral muscles resulting in stronger contractions during the swallow. The purpose of this investigation was to compare the intramuscular electromyographic activity of the mylohyoid, geniohyoid, and anterior belly of the digastric muscles during sour and water boluses with regard to duration, strength, and timing of muscle activation. Muscle duration, swallow onset time, and pattern of muscle activation did not differ for the two bolus types. Muscle activation time was more tightly approximated across the onsets of the three muscles when a sour bolus was used. A sour bolus also resulted in a stronger muscle contraction as evidenced by greater electromyographic activity. These data support the use of a sour bolus as part of a treatment paradigm.

  14. Removal of cyanobacterial toxins by sediment passage

    Science.gov (United States)

    Gruetzmacher, G.; Boettcher, G.; Chorus, I.; Bartel, H.

    2003-04-01

    Cyanbacterial toxins ("Cyanotoxins") comprise a wide range of toxic substances produced by cyanobacteria ("blue-green algae"). Cyanobacteria occur in surface water word wide and can be found in high concentrations during so-called algal blooms when conditions are favourable (e.g. high nutrient levels, high temperatures). Some cyanobacteria produce hepato- or neurotoxins, of which the hepatotoxic microcystins are the most common in Germany. The WHO guideline value for drinking water was set at 1 μg/L. However, maximum concentrations in surface water can reach 25 mg/L, so that a secure method for toxin elimination has to be found when this water is used as source water for drinking water production. In order to assess if cyanotoxins can be removed by sediment passage the German Federal Environmental Agency (UBA) conducted laboratory- and field scale experiments as well as observations on bank filtration field sites. Laboratory experiments (batch- and column experiments for adsorption and degradation parameters) were conducted in order to vary a multitude of experimental conditions. These experiments were followed by field scale experiments on the UBA's experimental field in Berlin. This plant offers the unique possibility to conduct experiments on the behaviour of various agents - such as harmful substances - during infiltration and bank filtration under well-defined conditions on a field scale, and without releasing these substances to the environment. Finally the development of microcystin concentrations was observed between infiltrating surface water and a drinking water well along a transsecte of observation wells. The results obtained show that infiltration and bank filtration normally seem to be secure treatment methods for source water contaminated by microcystins. However, elimination was shown to be difficult under the following circumstances: - dying cyanobacterial population due to insufficient light and / or nutrients, low temperatures or application of

  15. Sci—Thur AM: YIS - 07: Design and production of 3D printed bolus for electron radiation therapy

    Energy Technology Data Exchange (ETDEWEB)

    Su, Shiqin [Department of Physics and Atmospheric Science, Dalhousie University, Halifax, Nova Scotia (Canada); Moran, Kathryn [Queen Elizabeth II Health Sciences Centre, Nova Scotia Cancer Centre, Halifax, Nova Scotia (Canada); Robar, James L. [Department of Physics and Atmospheric Science, Dalhousie University, Halifax, Nova Scotia (Canada); Department of Radiation Oncology, Dalhousie University, Halifax, Nova Scotia (Canada)

    2014-08-15

    This is a proof-of-concept study demonstrating the capacity for modulated electron radiation therapy (MERT) using 3D printed bolus. Previous reports have involved bolus design using an electron pencil beam model and fabrication using a milling machine. In this study, an in-house algorithm is presented that optimizes the dose distribution with regard to dose coverage, conformity and homogeneity within planning target volume (PTV). The algorithm uses calculated result of a commercial electron Monte Carlo dose calculation as input. Distances along ray lines from distal side of 90% isodose to distal surface of PTV are used to estimate the bolus thickness. Inhomogeneities within the calculation volume are accounted for using coefficient of equivalent thickness method. Several regional modulation operators are applied to improve dose coverage and uniformity. The process is iterated (usually twice) until an acceptable MERT plan is realized, and the final bolus is printed using solid polylactic acid. The method is evaluated with regular geometric phantoms, anthropomorphic phantoms and a clinical rhabdomyosarcoma pediatric case. In all cases the dose conformity is improved compared to that with uniform bolus. The printed boluses conform well to the surface of complex anthropomorphic phantoms. For the rhabdomyosarcoma patient, the MERT plan yields a reduction of mean dose by 38.2% in left kidney relative to uniform bolus. MERT using 3D printed bolus appears to be a practical, low cost approach to generating optimized bolus for electron therapy. The method is effective in improving conformity of prescription isodose surface and in sparing immediately adjacent normal tissues.

  16. Sci—Thur AM: YIS - 07: Design and production of 3D printed bolus for electron radiation therapy

    International Nuclear Information System (INIS)

    Su, Shiqin; Moran, Kathryn; Robar, James L.

    2014-01-01

    This is a proof-of-concept study demonstrating the capacity for modulated electron radiation therapy (MERT) using 3D printed bolus. Previous reports have involved bolus design using an electron pencil beam model and fabrication using a milling machine. In this study, an in-house algorithm is presented that optimizes the dose distribution with regard to dose coverage, conformity and homogeneity within planning target volume (PTV). The algorithm uses calculated result of a commercial electron Monte Carlo dose calculation as input. Distances along ray lines from distal side of 90% isodose to distal surface of PTV are used to estimate the bolus thickness. Inhomogeneities within the calculation volume are accounted for using coefficient of equivalent thickness method. Several regional modulation operators are applied to improve dose coverage and uniformity. The process is iterated (usually twice) until an acceptable MERT plan is realized, and the final bolus is printed using solid polylactic acid. The method is evaluated with regular geometric phantoms, anthropomorphic phantoms and a clinical rhabdomyosarcoma pediatric case. In all cases the dose conformity is improved compared to that with uniform bolus. The printed boluses conform well to the surface of complex anthropomorphic phantoms. For the rhabdomyosarcoma patient, the MERT plan yields a reduction of mean dose by 38.2% in left kidney relative to uniform bolus. MERT using 3D printed bolus appears to be a practical, low cost approach to generating optimized bolus for electron therapy. The method is effective in improving conformity of prescription isodose surface and in sparing immediately adjacent normal tissues

  17. Perception of Diabetic Patients Regarding Basal Bolus Insulin Injections and Outcome of its Use

    International Nuclear Information System (INIS)

    Shahid, M.; Sarfraz, A.; Mahar, S. A.; Alam, M.; Shaikh, S.; Shahid, N.

    2016-01-01

    Objective: To assess the perceptions regarding basal bolus insulin injections and the changes in blood glucose levels and glycosylated hemoglobin (HbA1c) before and after 3 months of such treatment in diabetic patients. Study Design: Quasi-experimental study. Place and Duration of Study: Department of Endocrinology, Liaquat National Hospital, Karachi, from December 2014 to March 2015. Methodology: A total of 222 diabetic patients started on basal bolus insulin injection were enrolled and asked to answer 17 questions. Those with complications of diabetes were excluded. Fasting blood glucose (FBS), random blood glucose (RBS) and HbA1c levels were checked initially, and after 3 months of getting basal bolus insulin. Paired t-test and chi-square test were used for determining p-value with significance at p < 0.05. Results: Majority (n=217, 97.7 percentage) of the patients were previously taking other insulins. Before starting this treatment, the mean FBS was 260.5 ± 52.2 mg/dl, RBS was 385.5 percentage 47.61 mg/dl and HbA1c was 12.76 percentage 1.92 percentage. After 3 months of treatment, FBS improved to 117.9 ± 14.2 mg/dl, RBS was 156.7 ± 17.09 mg/dl and HbA1c was 7.72 ± 4.41 percentage (p < 0.001). Two hundred and sixteen (97.3 percentage) patients believed that basal bolus insulin was started as their diabetes worsened; 15 (70.70 percentage) thought that their blood glucose control would improve with the use of this form of insulin. One hundred and ninety four (87.4 percentage) had fear of needle injections. Perceptions regarding hypoglycemia with this form of insulin were observed in 157 (70.7 percentage). One hundred and twenty seven (84.1 percentage) of the females and 51 (71.8 percentage) of the males thought that the basal bolus insulin regimen was too expensive (p=0.032). Conclusion: There were many misconceptions in patients who were started on basal bolus insulin. Marked improvement in blood glucose levels and HbA1c were observed after the use of this

  18. Using Tracer Technology to Characterize Contaminated Pipelines

    Energy Technology Data Exchange (ETDEWEB)

    Maresca, Joseph, W., Jr., Ph.D.; Bratton, Wesley, L., Ph.D., P.E.; Dickerson, Wilhelmina; Hales, Rochelle

    2005-12-30

    The Pipeline Characterization Using Tracers (PCUT) technique uses conservative and partitioning, reactive or other interactive tracers to remotely determine the amount of contaminant within a run of piping or ductwork. The PCUT system was motivated by a method that has been successfully used to characterize subsurface soil contaminants and is similar in operation to that of a gas chromatography column. By injecting a ?slug? of both conservative and partitioning tracers at one end (or section) of the piping and measuring the time history of the concentration of the tracers at the other end (or another section) of the pipe, the presence, location, and amount of contaminant within the pipe or duct can be determined. The tracers are transported along the pipe or duct by a gas flow field, typically air or nitrogen, which has a velocity that is slow enough so that the partitioning tracer has time to interact with the contaminant before the tracer slug completely passes over the contaminate region. PCUT not only identifies the presence of contamination, it also can locate the contamination along the pipeline and quantify the amount of residual. PCUT can be used in support of deactivation and decommissioning (D&D) of piping and ducts that may have been contaminated with hazardous chemicals such as chlorinated solvents, petroleum products, radioactive materials, or heavy metals, such as mercury.

  19. SU-C-213-05: Evaluation of a Composite Copper-Plastic Material for a 3D Printed Radiation Therapy Bolus

    Energy Technology Data Exchange (ETDEWEB)

    Vitzthum, L; Ehler, E; Sterling, D; Reynolds, T; Higgins, P; Dusenbery, K [University of Minnesota, Minneapolis, MN (United States)

    2015-06-15

    Purpose: To evaluate a novel 3D printed bolus fabricated from a copper-plastic composite as a thin flexible, custom fitting device that can replicate doses achieved with conventional bolus techniques. Methods: Two models of bolus were created on a 3D printer using a composite copper-PLA/PHA. Firstly, boluses were constructed at thicknesses of 0.4, 0.6 and 0.8 mm. Relative dose measurements were performed under the bolus with an Attix Chamber as well as with radiochromic film. Results were compared to superficial Attix Chamber measurements in a water equivalent material to determine the dosimetric water equivalence of the copper-PLA/PHA plastic. Secondly, CT images of a RANDO phantom were used to create a custom fitting bolus across the anterolateral scalp. Surface dose with the bolus placed on the RANDO phantom was measured with radiochromic film at tangential angles with 6, 10, 10 flattening filter free (FFF) and 18 MV photon beams. Results: Mean surface doses for 6, 10, 10FFF and 18 MV were measured as a percent of Dmax for the flat bolus devices of each thickness. The 0.4 mm thickness bolus was determined to be near equivalent to 2.5 mm depth in water for all four energies. Surface doses ranged from 59–63% without bolus and 85–90% with the custom 0.4 mm copper-plastic bolus relative to the prescribed dose for an oblique tangential beam arrangement on the RANDO phantom. Conclusion: Sub-millimeter thickness, 3D printed composite copper-PLA/PHA bolus can provide a build-up effect equivalent to conventional bolus. At this thickness, the 3D printed bolus allows a level of flexure that may provide more patient comfort than current 3D printing materials used in bolus fabrication while still retaining the CT based custom patient shape. Funding provided by an intra-department grant of the University of Minnesota Department of Radiation Oncology.

  20. SU-C-213-05: Evaluation of a Composite Copper-Plastic Material for a 3D Printed Radiation Therapy Bolus

    International Nuclear Information System (INIS)

    Vitzthum, L; Ehler, E; Sterling, D; Reynolds, T; Higgins, P; Dusenbery, K

    2015-01-01

    Purpose: To evaluate a novel 3D printed bolus fabricated from a copper-plastic composite as a thin flexible, custom fitting device that can replicate doses achieved with conventional bolus techniques. Methods: Two models of bolus were created on a 3D printer using a composite copper-PLA/PHA. Firstly, boluses were constructed at thicknesses of 0.4, 0.6 and 0.8 mm. Relative dose measurements were performed under the bolus with an Attix Chamber as well as with radiochromic film. Results were compared to superficial Attix Chamber measurements in a water equivalent material to determine the dosimetric water equivalence of the copper-PLA/PHA plastic. Secondly, CT images of a RANDO phantom were used to create a custom fitting bolus across the anterolateral scalp. Surface dose with the bolus placed on the RANDO phantom was measured with radiochromic film at tangential angles with 6, 10, 10 flattening filter free (FFF) and 18 MV photon beams. Results: Mean surface doses for 6, 10, 10FFF and 18 MV were measured as a percent of Dmax for the flat bolus devices of each thickness. The 0.4 mm thickness bolus was determined to be near equivalent to 2.5 mm depth in water for all four energies. Surface doses ranged from 59–63% without bolus and 85–90% with the custom 0.4 mm copper-plastic bolus relative to the prescribed dose for an oblique tangential beam arrangement on the RANDO phantom. Conclusion: Sub-millimeter thickness, 3D printed composite copper-PLA/PHA bolus can provide a build-up effect equivalent to conventional bolus. At this thickness, the 3D printed bolus allows a level of flexure that may provide more patient comfort than current 3D printing materials used in bolus fabrication while still retaining the CT based custom patient shape. Funding provided by an intra-department grant of the University of Minnesota Department of Radiation Oncology

  1. Tracers vs. trajectories in a coastal region

    Science.gov (United States)

    Engqvist, A.; Döös, K.

    2008-12-01

    Two different methods of estimating the water exchange through a Baltic coastal region have been used, consisting of particle trajectories and passive tracers. Water is traced from and to a small discharge region near the coast. The discharge material in this region is treated as zero dimensional particles or tracers with neutral buoyancy. The real discharge material could be a leakage of radio-nuclides through the sea floor from an underground repository of nuclear waste. Water exchange rates between the discharge region and the model domain are estimated using both forward and backward trajectories as well as passive tracers. The Lagrangian trajectories can account for the time evolution of the water exchange while the tracers give one average age per model grid box. Water exchange times such as residence time, age and transient times have been calculated with trajectories but only the average age (AvA) for tracers. The trajectory calculations provide a more detailed time evolution than the tracers. On the other hand the tracers are integrated "on-line" simultaneously in the sea circulation model with the same time step while the Lagrangian trajectories are integrated "off-line" from the stored model velocities with its inherent temporal resolution, presently one hour. The sub-grid turbulence is parameterised as a Laplacian diffusion for the passive tracers and with an extra stochastic velocity for trajectories. The importance of the parameterised sub-grid turbulence for the trajectories is estimated to give an extra diffusion of the same order as the Laplacian diffusion by comparing the Lagrangian dispersions with and without parameterisation. The results of the different methods are similar but depend on the chosen diffusivity coefficient with a slightly higher correlation between trajectories and tracers when integrated with a lower diffusivity coefficient.

  2. Statistically Based Morphodynamic Modeling of Tracer Slowdown

    Science.gov (United States)

    Borhani, S.; Ghasemi, A.; Hill, K. M.; Viparelli, E.

    2017-12-01

    Tracer particles are used to study bedload transport in gravel-bed rivers. One of the advantages associated with using of tracer particles is that they allow for direct measures of the entrainment rates and their size distributions. The main issue in large scale studies with tracer particles is the difference between tracer stone short term and long term behavior. This difference is due to the fact that particles undergo vertical mixing or move to less active locations such as bars or even floodplains. For these reasons the average virtual velocity of tracer particle decreases in time, i.e. the tracer slowdown. In summary, tracer slowdown can have a significant impact on the estimation of bedload transport rate or long term dispersal of contaminated sediment. The vast majority of the morphodynamic models that account for the non-uniformity of the bed material (tracer and not tracer, in this case) are based on a discrete description of the alluvial deposit. The deposit is divided in two different regions; the active layer and the substrate. The active layer is a thin layer in the topmost part of the deposit whose particles can interact with the bed material transport. The substrate is the part of the deposit below the active layer. Due to the discrete representation of the alluvial deposit, active layer models are not able to reproduce tracer slowdown. In this study we try to model the slowdown of tracer particles with the continuous Parker-Paola-Leclair morphodynamic framework. This continuous, i.e. not layer-based, framework is based on a stochastic description of the temporal variation of bed surface elevation, and of the elevation specific particle entrainment and deposition. Particle entrainment rates are computed as a function of the flow and sediment characteristics, while particle deposition is estimated with a step length formulation. Here we present one of the first implementation of the continuum framework at laboratory scale, its validation against

  3. Culvert Length and Interior Lighting Impacts to Topeka Shiner Passage

    Science.gov (United States)

    2017-11-01

    Culverts can act as barriers to fish passage for a number of reasons including insufficient water depth or excess velocity. In addition, concern is being raised over behavioral barriers where culvert conditions elicit an avoidance response that deter...

  4. Should colloid boluses be prioritized over crystalloid boluses for the management of dengue shock syndrome in the presence of ascites and pleural effusions?

    Directory of Open Access Journals (Sweden)

    Weerasinghe Mindu

    2011-02-01

    Full Text Available Abstract Background Although the WHO guideline for the management of dengue fever considers the presence of ascites or pleural effusions in the diagnosis of DSS, it does not emphasize the importance of their presence when selecting fluids for resuscitation. Case presentation We highlight three patients with DSS who received boluses of crystalloids on priority basis as recommended by WHO guidelines during resuscitation. All three patients had varying degrees of third space fluid loss (ascites and pleural effusions at the time of development of DSS. Ascites and pleural effusions were detected in all 3 patients at the time of shock irrespective of whether iv fluids were given or not. All three patients had documented liver involvement at the time of shock evidenced by elevation of AST (4800 iu/L, 5000 iu/L and 1960 iu/L. One patient who had profound shock died 6 hours after admission with evidence of acute pulmonary oedema in the convalescence phase. All of them needed CPAP ventilator support and potent diuretics. Conclusions We therefore feel that resuscitation of patients with DSS who already have third space fluid accumulation with crystalloid boluses on priority basis may contribute to recovery phase pulmonary oedema.

  5. SU-F-T-500: The Effectiveness of a Patient Specific Bolus Made by Using Three-Dimensional Printing Technique in Photon Radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Fujimoto, K; Yuasa, Y [Department of Radiological Technology, Yamaguchi University Hospital (Japan); Shiinoki, T; Hanazawa, H; Shibuya, K [Department of Radiation Oncology, Graduate school of Medicine, Yamaguchi University (Japan)

    2016-06-15

    Purpose: A commercially available bolus (commercial-bolus) would not completely contact with the irregular shape of a patient’s skin. The purposes of this study were to customize a patient specific three-dimensional (3D) bolus using a 3D printer (3D-bolus) and to evaluate its clinical feasibility for photon radiotherapy. Methods: The 3D-bolus was designed using a treatment planning system (TPS) in DICOM-RT format. To print the 3D bolus, the file was converted into stereolithography format. To evaluate its physical characteristics, plans were created for water equivalent phantoms without the bolus, with the 3D-bolus printed in a flat form, and with the virtual bolus which supposed a commercial-bolus. These plans were compared with the percent depth dose (PDD) measured from the TPS. Furthermore, to evaluate its clinical feasibility, the treatment plans were created for RANDO phantoms without the bolus and with the 3D-bolus which was customized for contacting with the surface of the phantom. Both plans were compared with the dose volume histogram (DVH) of the target volume. Results: In the physical evaluation, dmax of the plan without the bolus, with the 3D-bolus, and with the virtual bolus were 2.2 cm, 1.6 cm, and 1.7 cm, respectively. In the evaluation of clinical feasibility, for the plan without the bolus, Dmax, Dmin, Dmean, D90%, and V90% of the target volume were 102.6 %, 1.6 %, 88.8 %, 57.2 %, and 69.3 %, respectively. By using the 3D-bolus, the prescription dose could be delivered to at least 90 % of the target volume, Dmax, Dmin, Dmean, D90%, and V90% of the target volume were 104.3 %, 91.6 %, 92.1 %, 91.7 %, and 98.0 %, respectively. The 3D-bolus has the potential to be useful for providing effective dose coverage in the buildup region. Conclusion: A 3D-bolus produced using 3D printing technique is comparable to a commercially available bolus.

  6. SU-F-T-500: The Effectiveness of a Patient Specific Bolus Made by Using Three-Dimensional Printing Technique in Photon Radiotherapy

    International Nuclear Information System (INIS)

    Fujimoto, K; Yuasa, Y; Shiinoki, T; Hanazawa, H; Shibuya, K

    2016-01-01

    Purpose: A commercially available bolus (commercial-bolus) would not completely contact with the irregular shape of a patient’s skin. The purposes of this study were to customize a patient specific three-dimensional (3D) bolus using a 3D printer (3D-bolus) and to evaluate its clinical feasibility for photon radiotherapy. Methods: The 3D-bolus was designed using a treatment planning system (TPS) in DICOM-RT format. To print the 3D bolus, the file was converted into stereolithography format. To evaluate its physical characteristics, plans were created for water equivalent phantoms without the bolus, with the 3D-bolus printed in a flat form, and with the virtual bolus which supposed a commercial-bolus. These plans were compared with the percent depth dose (PDD) measured from the TPS. Furthermore, to evaluate its clinical feasibility, the treatment plans were created for RANDO phantoms without the bolus and with the 3D-bolus which was customized for contacting with the surface of the phantom. Both plans were compared with the dose volume histogram (DVH) of the target volume. Results: In the physical evaluation, dmax of the plan without the bolus, with the 3D-bolus, and with the virtual bolus were 2.2 cm, 1.6 cm, and 1.7 cm, respectively. In the evaluation of clinical feasibility, for the plan without the bolus, Dmax, Dmin, Dmean, D90%, and V90% of the target volume were 102.6 %, 1.6 %, 88.8 %, 57.2 %, and 69.3 %, respectively. By using the 3D-bolus, the prescription dose could be delivered to at least 90 % of the target volume, Dmax, Dmin, Dmean, D90%, and V90% of the target volume were 104.3 %, 91.6 %, 92.1 %, 91.7 %, and 98.0 %, respectively. The 3D-bolus has the potential to be useful for providing effective dose coverage in the buildup region. Conclusion: A 3D-bolus produced using 3D printing technique is comparable to a commercially available bolus.

  7. Comparison of first pass bolus AIFs extracted from sequential {sup 18}F-FDG PET and DSC-MRI of mice

    Energy Technology Data Exchange (ETDEWEB)

    Evans, Eleanor, E-mail: ee244@cam.ac.uk [Wolfson Brain Imaging Centre, Department of Clinical Neurosciences, School of Clinical Medicine, University of Cambridge, Cambridge Biomedical Campus, Cambridge, CB2 0QQ (United Kingdom); Sawiak, Stephen J. [Wolfson Brain Imaging Centre, Department of Clinical Neurosciences, School of Clinical Medicine, University of Cambridge, Cambridge Biomedical Campus, Cambridge, CB2 0QQ (United Kingdom); Behavioural and Clinical Neuroscience Institute, Department of Experimental Psychology, University of Cambridge, Cambridge, CB2 3EB (United Kingdom); Ward, Alexander O.; Buonincontri, Guido; Hawkes, Robert C.; Adrian Carpenter, T. [Wolfson Brain Imaging Centre, Department of Clinical Neurosciences, School of Clinical Medicine, University of Cambridge, Cambridge Biomedical Campus, Cambridge, CB2 0QQ (United Kingdom)

    2014-01-11

    Accurate kinetic modelling of in vivo physiological function using positron emission tomography (PET) requires determination of the tracer time–activity curve in plasma, known as the arterial input function (AIF). The AIF is usually determined by invasive blood sampling methods, which are prohibitive in murine studies due to low total blood volumes. Extracting AIFs from PET images is also challenging due to large partial volume effects (PVE). We hypothesise that in combined PET with magnetic resonance imaging (PET/MR), a co-injected bolus of MR contrast agent and PET ligand can be tracked using fast MR acquisitions. This protocol would allow extraction of a MR AIF from MR contrast agent concentration–time curves, at higher spatial and temporal resolution than an image-derived PET AIF. A conversion factor could then be applied to the MR AIF for use in PET kinetic analysis. This work has compared AIFs obtained from sequential DSC-MRI and PET with separate injections of gadolinium contrast agent and {sup 18}F-FDG respectively to ascertain the technique′s validity. An automated voxel selection algorithm was employed to improve MR AIF reproducibility. We found that MR and PET AIFs displayed similar character in the first pass, confirmed by gamma variate fits (p<0.02). MR AIFs displayed reduced PVE compared to PET AIFs, indicating their potential use in PET/MR studies.

  8. Fish passage hydroelectric power plant Linne, Netherlands. Didson measurements

    International Nuclear Information System (INIS)

    Van Keeken, O.A.; Griffioen, A.B.

    2011-11-01

    The hydroelectric power plant in the Dutch Maas River near Linne has a fish deflection and passage system. For this study, two evenings in the months of August and September 2011 were dedicated to examining the extent to which fish approached and used the fish passage system. To establish the swimming behavior of the fish, a high-resolution sonar (DIDSON) was used, which generates moving images of fish in turbid waters, to study their behavior. [nl

  9. An Economic Analysis of Container Shipping Through Canadian Northwest Passage

    Directory of Open Access Journals (Sweden)

    Dongqin Lu

    2014-12-01

    This paper considers Canada's sovereignty in matters of navigation over the waters at the Arctic Archipelago, in the form of a toll fee for passage usage. We concluded that the NWP has an advantage over the Panama Canal if it is open for free international passage, regardless of ship size. However, if it is not free, its advantages depend on its toll fee. The lower the toll fee is, the more advantages the NWP will boast.

  10. The future of fish passage science, engineering, and practice

    Science.gov (United States)

    Silva, Ana T.; Lucas, Martyn C.; Castro-Santos, Theodore R.; Katopodis, Christos; Baumgartner, Lee J.; Thiem, Jason D.; Aarestrup, Kim; Pompeu, Paulo S.; O'Brien, Gordon C.; Braun, Douglas C.; Burnett, Nicholas J.; Zhu, David Z.; Fjeldstad, Hans-Petter; Forseth, Torbjorn; Rajarathnam, Nallamuthu; Williams, John G.; Cooke, Steven J.

    2018-01-01

    Much effort has been devoted to developing, constructing and refining fish passage facilities to enable target species to pass barriers on fluvial systems, and yet, fishway science, engineering and practice remain imperfect. In this review, 17 experts from different fish passage research fields (i.e., biology, ecology, physiology, ecohydraulics, engineering) and from different continents (i.e., North and South America, Europe, Africa, Australia) identified knowledge gaps and provided a roadmap for research priorities and technical developments. Once dominated by an engineering‐focused approach, fishway science today involves a wide range of disciplines from fish behaviour to socioeconomics to complex modelling of passage prioritization options in river networks. River barrier impacts on fish migration and dispersal are currently better understood than historically, but basic ecological knowledge underpinning the need for effective fish passage in many regions of the world, including in biodiversity hotspots (e.g., equatorial Africa, South‐East Asia), remains largely unknown. Designing efficient fishways, with minimal passage delay and post‐passage impacts, requires adaptive management and continued innovation. While the use of fishways in river restoration demands a transition towards fish passage at the community scale, advances in selective fishways are also needed to manage invasive fish colonization. Because of the erroneous view in some literature and communities of practice that fish passage is largely a proven technology, improved international collaboration, information sharing, method standardization and multidisciplinary training are needed. Further development of regional expertise is needed in South America, Asia and Africa where hydropower dams are currently being planned and constructed.

  11. Algorithms for Brownian first-passage-time estimation

    Science.gov (United States)

    Adib, Artur B.

    2009-09-01

    A class of algorithms in discrete space and continuous time for Brownian first-passage-time estimation is considered. A simple algorithm is derived that yields exact mean first-passage times (MFPTs) for linear potentials in one dimension, regardless of the lattice spacing. When applied to nonlinear potentials and/or higher spatial dimensions, numerical evidence suggests that this algorithm yields MFPT estimates that either outperform or rival Langevin-based (discrete time and continuous space) estimates.

  12. Fire passage on geomorphic fractures in Cerrado: effect on vegetation

    OpenAIRE

    Otacílio Antunes Santana; José Marcelo Imaña Encinas; Flávio Luiz de Souza Silveira

    2017-01-01

    Geomorphic fracture is a natural geologic formation that sometimes forms a deep fissure in the rock with the establishment of soil and vegetation. The objective of this work was to analyze vegetation within geomorphic fractures under the effect of wildfire passage. The biometric variables evaluated before and after fire passage were: diameter, height, leaf area index, timber volume, grass biomass, number of trees and shrubs and of species. Results (in fractures) were compared to adjacent area...

  13. The accurate particle tracer code

    Science.gov (United States)

    Wang, Yulei; Liu, Jian; Qin, Hong; Yu, Zhi; Yao, Yicun

    2017-11-01

    The Accurate Particle Tracer (APT) code is designed for systematic large-scale applications of geometric algorithms for particle dynamical simulations. Based on a large variety of advanced geometric algorithms, APT possesses long-term numerical accuracy and stability, which are critical for solving multi-scale and nonlinear problems. To provide a flexible and convenient I/O interface, the libraries of Lua and Hdf5 are used. Following a three-step procedure, users can efficiently extend the libraries of electromagnetic configurations, external non-electromagnetic forces, particle pushers, and initialization approaches by use of the extendible module. APT has been used in simulations of key physical problems, such as runaway electrons in tokamaks and energetic particles in Van Allen belt. As an important realization, the APT-SW version has been successfully distributed on the world's fastest computer, the Sunway TaihuLight supercomputer, by supporting master-slave architecture of Sunway many-core processors. Based on large-scale simulations of a runaway beam under parameters of the ITER tokamak, it is revealed that the magnetic ripple field can disperse the pitch-angle distribution significantly and improve the confinement of energetic runaway beam on the same time.

  14. Development of Radioisotope Tracer Technology

    International Nuclear Information System (INIS)

    Jung, Sung Hee; Jin, Joon Ha; Kim, Jong Bum; Kim, Jin Seop; Kim, Jae Jo; Park, Soon Chul; Lim, Don Soon; Choi, Byung Jong; Jang, Dong Soon; Kim, Hye Sook

    2007-06-01

    The project is aimed to develop the radiotracer technology for process optimization and trouble-shooting to establish the environmental and industrial application of radiation and radioisotopes. The advanced equipment and software such as high speed data acquisition system, RTD model and high pressure injection tool have developed. Based on the various field application to the refinery/petrochemical industries, the developed technology was transfer to NDT company for commercial service. For the environmental application of radiotracer technology, injector, detector sled, core sampler, RI and GPS data logging system are developed and field tests were implemented successfully at Wolsung and Haeundae beach. Additionally tracer technology were also used for the performance test of the clarifier in a wastewater treatment plant and for the leak detection in reservoirs. From the experience of case studies on radiotracer experiment in waste water treatment facilities, 'The New Excellent Technology' is granted from the ministry of environment. For future technology, preliminary research for industrial gamma transmission and emission tomography which are new technology combined with radioisotope and image reconstruction are carried out

  15. Compartmental modeling and tracer kinetics

    CERN Document Server

    Anderson, David H

    1983-01-01

    This monograph is concerned with mathematical aspects of compartmental an­ alysis. In particular, linear models are closely analyzed since they are fully justifiable as an investigative tool in tracer experiments. The objective of the monograph is to bring the reader up to date on some of the current mathematical prob­ lems of interest in compartmental analysis. This is accomplished by reviewing mathematical developments in the literature, especially over the last 10-15 years, and by presenting some new thoughts and directions for future mathematical research. These notes started as a series of lectures that I gave while visiting with the Division of Applied ~1athematics, Brown University, 1979, and have developed in­ to this collection of articles aimed at the reader with a beginning graduate level background in mathematics. The text can be used as a self-paced reading course. With this in mind, exercises have been appropriately placed throughout the notes. As an aid in reading the material, the e~d of a ...

  16. A Factor Increasing Venous Contamination on Bolus Chase Three-dimensional Magnetic Resonance Imaging: Charcot Neuroarthropathy.

    Science.gov (United States)

    Çildağ, Mehmet B; Ertuğrul, Mustafa B; Köseoğlu, Ömer Fk; Armstrong, David G

    2018-01-01

    The study aimed to evaluate the ratio of venous contamination in diabetic cases without foot lesion, with foot lesion and with Charcot neuroarthropathy (CN). Bolus-chase three-dimensional magnetic resonance (MR) of 396 extremities of patients with diabetes mellitus was analyzed, retrospectively. Extremities were divided into three groups as follows: diabetic patients without foot ulcer or Charcot arthropathy (Group A), patients with diabetic foot ulcers (Group B) and patients with CN accompanying diabetic foot ulcers (Group C). Furthermore, amount of venous contamination classified as no venous contamination, mild venous contamination, and severe venous contamination. The relationship between venous contamination and extremity groups was investigated. Severe venous contamination was seen in Group A, Group B, and Group C, 5.6%, 15.2%, and 34.1%, respectively. Statistically significant difference was seen between groups with regard to venous contamination. Venous contamination following bolus chase MR was higher in patients with CN.

  17. A factor increasing venous contamination on bolus chase three-dimensional magnetic resonance imaging: Charcot neuroarthropathy

    Directory of Open Access Journals (Sweden)

    Mehmet B Cildag

    2018-01-01

    Full Text Available Background: The study aimed to evaluate the ratio of venous contamination in diabetic cases without foot lesion, with foot lesion and with Charcot neuroarthropathy (CN. Materials and Methods: Bolus-chase three-dimensional magnetic resonance (MR of 396 extremities of patients with diabetes mellitus was analyzed, retrospectively. Extremities were divided into three groups as follows: diabetic patients without foot ulcer or Charcot arthropathy (Group A, patients with diabetic foot ulcers (Group B and patients with CN accompanying diabetic foot ulcers (Group C. Furthermore, amount of venous contamination classified as no venous contamination, mild venous contamination, and severe venous contamination. The relationship between venous contamination and extremity groups was investigated. Results: Severe venous contamination was seen in Group A, Group B, and Group C, 5.6%, 15.2%, and 34.1%, respectively. Statistically significant difference was seen between groups with regard to venous contamination. Conclusion: Venous contamination following bolus chase MR was higher in patients with CN.

  18. Review of adverse reactions, including anaphylaxis, in 4,260 intravenous bolus injections

    International Nuclear Information System (INIS)

    Kanal, E.; Applegate, G.R.; Gillen, C.P.

    1990-01-01

    This paper evaluates the incidence and type of adverse reactions to Gd-DTPA (Magnevist) after bolus administration in an active clinical MR setting. Between May 1988 and March 1990, 4,260 bolus intravenous injections of Gd-DTPA, 0.1 mmol/kg, were administered during clinical MR examinations. Patient tolerance and reactions were recorded in each instance. All cases of suspected local infiltration were excluded from this study. Review of this data revealed 15 instances of nausea and 12 of emesis following contrast administration. In addition, there were five or fewer cases of associated headaches, dizziness, odd tastes, seizures (with prior seizure histories) mild chest pain, palpitations, hives, or wheezing

  19. Hydroacoustic Evaluation of Fish Passage through Bonneville Dam in 2004

    Energy Technology Data Exchange (ETDEWEB)

    Ploskey, Gene R.; Weiland, Mark A.; Schilt, Carl R.; Kim, Jina; Johnson, Peter N.; Hanks, Michael E.; Patterson, Deborah S.; Skalski, John R.; Hedgepeth, J

    2005-12-22

    The Portland District of the U.S. Army Corps of Engineers requested that the Pacific Northwest National Laboratory (PNNL) conduct fish-passage studies at Bonneville Dam in 2004. These studies support the Portland District's goal of maximizing fish-passage efficiency (FPE) and obtaining 95% survival for juvenile salmon passing Bonneville Dam. Major passage routes include 10 turbines and a sluiceway at Powerhouse 1 (B1), an 18-bay spillway, and eight turbines and a sluiceway at Powerhouse 2 (B2). In this report, we present results of four studies related to juvenile salmonid passage at Bonneville Dam. The studies were conducted between April 15 and July 15, 2004, encompassing most of the spring and summer migrations. Studies included evaluations of (1) Project fish passage efficiency and other major passage metrics, (2) B2 fish guidance efficiency and gap loss, (3) smolt approach and fate at the B2 Corner Collector (B2CC), and (4) B2 vertical barrier screen head differential.

  20. Shape design of internal cooling passages within a turbine blade

    Science.gov (United States)

    Nowak, Grzegorz; Nowak, Iwona

    2012-04-01

    The article concerns the optimization of the shape and location of non-circular passages cooling the blade of a gas turbine. To model the shape, four Bezier curves which form a closed profile of the passage were used. In order to match the shape of the passage to the blade profile, a technique was put forward to copy and scale the profile fragments into the component, and build the outline of the passage on the basis of them. For so-defined cooling passages, optimization calculations were carried out with a view to finding their optimal shape and location in terms of the assumed objectives. The task was solved as a multi-objective problem with the use of the Pareto method, for a cooling system composed of four and five passages. The tool employed for the optimization was the evolutionary algorithm. The article presents the impact of the population on the task convergence, and discusses the impact of different optimization objectives on the Pareto optimal solutions obtained. Due to the problem of different impacts of individual objectives on the position of the solution front which was noticed during the calculations, a two-step optimization procedure was introduced. Also, comparative optimization calculations for the scalar objective function were carried out and set up against the non-dominated solutions obtained in the Pareto approach. The optimization process resulted in a configuration of the cooling system that allows a significant reduction in the temperature of the blade and its thermal stress.

  1. Flow in Rotating Serpentine Coolant Passages With Skewed Trip Strips

    Science.gov (United States)

    Tse, David G.N.; Steuber, Gary

    1996-01-01

    Laser velocimetry was utilized to map the velocity field in serpentine turbine blade cooling passages with skewed trip strips. The measurements were obtained at Reynolds and Rotation numbers of 25,000 and 0.24 to assess the influence of trips, passage curvature and Coriolis force on the flow field. The interaction of the secondary flows induced by skewed trips with the passage rotation produces a swirling vortex and a corner recirculation zone. With trips skewed at +45 deg, the secondary flows remain unaltered as the cross-flow proceeds from the passage to the turn. However, the flow characteristics at these locations differ when trips are skewed at -45 deg. Changes in the flow structure are expected to augment heat transfer, in agreement with the heat transfer measurements of Johnson, et al. The present results show that trips are skewed at -45 deg in the outward flow passage and trips are skewed at +45 deg in the inward flow passage maximize heat transfer. Details of the present measurements were related to the heat transfer measurements of Johnson, et al. to relate fluid flow and heat transfer measurements.

  2. Post-mastectomy radiation therapy without usage of a bolus may be a reasonable option

    International Nuclear Information System (INIS)

    Nakamura, Naoki; Arahira, Satoko; Zenda, Sadamoto; Yoneyama, Kimiyasu; Mukai, Hirofumi; Onozawa, Masakatsu; Toshima, Masamichi; Motegi, Atsushi; Hirano, Yasuhiro; Hojo, Hidehiro; Kibe, Yuichi; Akimoto, Tetsuo

    2017-01-01

    To clarify the efficacy and toxicity of post-mastectomy radiation therapy (PMRT) without usage of a bolus, we identified 129 consecutive patients who received PMRT at the National Cancer Center Hospital East between 2003 and 2012. Seven of the 129 patients who received breast reconstruction before PMRT were excluded. All patients received PMRT of 6 MV photons, without usage of a bolus. The median follow-up duration for all eligible patients was 47.7 months (range: 4.0–123.2). Local, locoregional and isolated locoregional recurrence was found in 12 (9.8%), 14 (11%) and 5 patients (4.1%), respectively. The 3- and 5-year cumulative incidence of local recurrence, locoregional recurrence and isolated locoregional recurrence was 9.2 and 10.7%, 10.8 and 12.4%, and 4.3 and 4.3%, respectively. Although Grade 2 dermatitis was found in 11 patients (9.0%), no Grade 3–4 dermatitis was found. On univariate analysis, only a non-luminal subtype was a significant predictor for local recurrence (P < 0.001). On multivariate analysis, a non-luminal subtype remained as an independent predictor for local recurrence (P = 0.003, odds ratio: 10.9, 95% confidence interval: 2.23–53.1). In conclusion, PMRT without usage of a bolus resulted in a low rate of severe acute dermatitis without an apparent increase in local recurrence. PMRT without usage of a bolus may be reasonable, especially for patients with a luminal subtype.

  3. Replacement of oxytocin bolus administration by infusion: influences on postpartum outcome.

    Science.gov (United States)

    Löytved-Hardegg, Julia J; Brunner, Mirjam; Ries, Jean-Jacques; von Felten, Stefanie; Heugel, Christina; Lapaire, Olav; Voekt, Cora; Hösli, Irene

    2016-06-01

    Postpartum haemorrhage (PPH) represents a leading cause of maternal morbidity and mortality. Giving oxytocin after birth reduces the risk for PPH. It has never been tested whether different methods of oxytocin administration affect the maternal outcome. This study aims to compare the infusion versus the bolus application of oxytocin after singleton vaginal delivery. This retrospective monocentre study compares the incidence of clinically relevant postpartum complications in women receiving 5 IE of oxytocin as a bolus or as a 100 ml-infusion over 5 min, given immediately after birth. Included were women delivering singletons vaginally at term. We used propensity score weighting to compare outcomes between women receiving bolus and infusion and to minimize the selection bias in this retrospective cohort. 1765 patients were included. Patient characteristics were balanced. We found no significant differences for the combined overall postpartum adverse outcome (the incidence of PPH, manual removal of the placenta and/or curettage). For the single outcomes, we observed a significantly higher frequency of manual removal of the placenta (Odds ratio 1.47, 95 % CI 1.02-2.13) and a slightly higher but clinically not relevant estimated blood loss (Relative effect 1.05, 95 % CI 1.01-1.10) in the infusion group. The data show a tendency towards more complications in the infusion group. It is related to a more frequent need for manual removal of the placenta.

  4. Bolus electron conformal therapy for the treatment of recurrent inflammatory breast cancer: a case report

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Michelle M., E-mail: mmkim@mdanderson.org [Department of Radiation Oncology, University of Texas M.D. Anderson Cancer Center, Houston, TX (United States); Kudchadker, Rajat J.; Kanke, James E.; Zhang, Sean; Perkins, George H. [Department of Radiation Oncology, University of Texas M.D. Anderson Cancer Center, Houston, TX (United States)

    2012-07-01

    The treatment of locoregionally recurrent breast cancer in patients who have previously undergone radiation therapy is challenging. Special techniques are often required that both eradicate the disease and minimize the risks of retreatment. We report the case of a patient with an early-stage left breast cancer who developed inflammatory-type recurrence requiring re-irradiation of the chest wall using bolus electron conformal therapy with image-guided treatment delivery. The patient was a 51-year-old woman who had undergone lumpectomy, axillary lymph node dissection, and adjuvant whole-breast radiation therapy for a stage I left breast cancer in June 1998. In March 2009, she presented at our institution with biopsy-proven recurrent inflammatory carcinoma and was aggressively treated with multi-agent chemotherapy followed by mastectomy that left a positive surgical margin. Given the patient's prior irradiation and irregular chest wall anatomy, bolus electron conformal therapy was used to treat her chest wall and draining lymphatics while sparing the underlying soft tissue. The patient still had no evidence of disease 21 months after treatment. Our results indicate that bolus electron conformal therapy is an accessible, effective radiation treatment approach for recurrent breast cancer in patients with irregular chest wall anatomy as a result of surgery. This approach may complement standard techniques used to reduce locoregional recurrence in the postmastectomy setting.

  5. A mathematical model for the movement of food bolus of varying viscosities through the esophagus

    Science.gov (United States)

    Tripathi, Dharmendra

    2011-09-01

    This mathematical model is designed to study the influence of viscosity on swallowing of food bolus through the esophagus. Food bolus is considered as viscous fluid with variable viscosity. Geometry of esophagus is assumed as finite length channel and flow is induced by peristaltic wave along the length of channel walls. The expressions for axial velocity, transverse velocity, pressure gradient, volume flow rate and stream function are obtained under the assumptions of long wavelength and low Reynolds number. The impacts of viscosity parameter on pressure distribution, local wall shear stress, mechanical efficiency and trapping are numerically discussed with the help of computational results. On the basis of presented study, it is revealed that swallowing of low viscous fluids through esophagus requires less effort in comparison to fluids of higher viscosity. This result is similar to the experimental result obtained by Raut et al. [1], Dodds [2] and Ren et al. [3]. It is further concluded that the pumping efficiency increases while size of trapped bolus reduces when viscosity of fluid is high.

  6. Lower esophageal mucosal ring: correlation of referred symptoms with radiographic findings using a marshmallow bolus.

    Science.gov (United States)

    Smith, D F; Ott, D J; Gelfand, D W; Chen, M Y

    1998-11-01

    The purpose of this investigation was to determine the prevalence of lower esophageal mucosal rings and to correlate the relationship between these mucosal rings and the presence and anatomic level of symptoms evoked using a marshmallow bolus. Our prospective study included 130 patients who underwent barium examination of the esophagus. All patients completed a questionnaire regarding the anatomic location of their symptoms of dysphagia. In addition to a multiphasic examination of the esophagus, all patients also underwent fluoroscopic observation and videotaping while swallowing a marshmallow bolus; any symptoms that were provoked were recorded. Lower esophageal mucosal rings were shown in 26 (20%) of the 130 patients. The diameter of the rings was 9-12 mm in six patients, 13-20 mm in 18 patients, and larger than 20 mm in two patients. In 16 (62%) of the 26 patients, a marshmallow bolus became impacted at the ring; the impaction caused dysphagia in 12 (75%) of the 16 patients. In these 12 patients, dysphagia was referred to the neck in seven, the sternal angle in two, the mid chest in two, and the lower chest in one patient. None of the 12 patients had a pharyngeal or cervical esophageal abnormality that would account for their symptoms. Because proximal referral of symptoms is common in patients with lower esophageal mucosal rings, a thorough radiographic examination of the entire esophagus and esophagogastric region is required regardless of the level of their swallowing complaints.

  7. Evaluation of the esophagus with a marshmallow bolus: clarifying the cause of dysphagia.

    Science.gov (United States)

    Ott, D J; Kelley, T F; Chen, M Y; Gelfand, D W

    1991-01-01

    We reviewed the radiographic examinations of the esophagus and medical records in 117 patients (55 women and 62 men; mean age, 52 years) in which a marshmallow bolus was also given. A one-third to one-half piece of a standard marshmallow was used with a mean size of 23 mm (+/- 4.5 mm SD) measured in vivo. In 62 patients with no intrinsic structural narrowing of the esophagus, impaction occurred in only seven (11%). Four of these patients had an esophageal motility disorder, and three had a previous Nissen fundoplication. The remaining 55 patients had lower esophageal mucosal rings (47) or peptic strictures (8). Marshmallow impaction was seen in 27 of 47 rings (57%) and was inversely related to ring size, and in six of eight strictures (75%). Also, impaction was related to the ratio of bolus size to ring caliber, and invariably occurred when this ratio was greater than 1.5. Dysphagia was the presenting complaint in 76 (65%) patients, but was found equally in those without intrinsic narrowing and in those with ring or stricture. However, dysphagia was reproduced by the marshmallow bolus only in patients with esophageal narrowing or abnormal motility.

  8. In Silico Assessment of Literature Insulin Bolus Calculation Methods Accounting for Glucose Rate of Change.

    Science.gov (United States)

    Cappon, Giacomo; Marturano, Francesca; Vettoretti, Martina; Facchinetti, Andrea; Sparacino, Giovanni

    2018-05-01

    The standard formula (SF) used in bolus calculators (BCs) determines meal insulin bolus using "static" measurement of blood glucose concentration (BG) obtained by self-monitoring of blood glucose (SMBG) fingerprick device. Some methods have been proposed to improve efficacy of SF using "dynamic" information provided by continuous glucose monitoring (CGM), and, in particular, glucose rate of change (ROC). This article compares, in silico and in an ideal framework limiting the exposition to possibly confounding factors (such as CGM noise), the performance of three popular techniques devised for such a scope, that is, the methods of Buckingham et al (BU), Scheiner (SC), and Pettus and Edelman (PE). Using the UVa/Padova Type 1 diabetes simulator we generated data of 100 virtual subjects in noise-free, single-meal scenarios having different preprandial BG and ROC values. Meal insulin bolus was computed using SF, BU, SC, and PE. Performance was assessed with the blood glucose risk index (BGRI) on the 9 hours after meal. On average, BU, SC, and PE improve BGRI compared to SF. When BG is rapidly decreasing, PE obtains the best performance. In the other ROC scenarios, none of the considered methods prevails in all the preprandial BG conditions tested. Our study showed that, at least in the considered ideal framework, none of the methods to correct SF according to ROC is globally better than the others. Critical analysis of the results also suggests that further investigations are needed to develop more effective formulas to account for ROC information in BCs.

  9. Causes of death after fluid bolus resuscitation: new insights from FEAST.

    Science.gov (United States)

    Myburgh, John; Finfer, Simon

    2013-03-14

    The Fluid Expansion as Supportive Therapy (FEAST study) was an extremely well conducted study that gave unexpected results. The investigators had reported that febrile children with impaired perfusion treated in low-income countries without access to intensive care are more likely to die if they receive bolus resuscitation with albumin or saline compared with no bolus resuscitation at all. In a secondary analysis of the trial, published in BMC Medicine, the authors found that increased mortality was evident in patients who presented with clinical features of severe shock in isolation or in conjunction with features of respiratory or neurological failure. The cause of excess deaths was primarily refractory shock and not fluid overload. These features are consistent with a potential cardiotoxic or ischemia-reperfusion injury following resuscitation with boluses of intravenous fluid. Although these effects may have been amplified by the absence of invasive monitoring, mechanical ventilation or vasopressors, the results provide compelling insights into the effects of intravenous fluid resuscitation and potential adverse effects that extend beyond the initial resuscitation period. These data add to the increasing body of literature about the safety and efficacy of intravenous resuscitation fluids, which may be applicable to management of other populations of critically ill patients.

  10. Tracer surface diffusion on UO2

    International Nuclear Information System (INIS)

    Zhou, S.Y.; Olander, D.R.

    1983-06-01

    Surface diffusion on UO 2 was measured by the spreading of U-234 tracer on the surface of a duplex diffusion couple consisting of wafers of depleted and enriched UO 2 joined by a bond of uranium metal

  11. Custom bolus of hydrogel: dosimetric characterization, clinical use and placement uncertainties; Bolus de compensación personalizado de hidrogel: Caracterización radiológica, uso clínico e incertidumbre de colocación

    Energy Technology Data Exchange (ETDEWEB)

    Pérez-García, H.; Antón, D.; Miguel, D.; Ángel del Castillo, D.; Alonso, D.; De Frutos, J.; Pérez, C.

    2017-11-01

    When using electron beams over irregular surfaces it shows remarkable dose heterogeneity in target tissue, the use of a hydrogel bolus by Varihesive® ConvaTec as a custom bolus is proposed to compensate this effect. Radiological characterization is carried out comparing hydrogel with water by a CT study and by measuring percentage depth dose for electron beams. The dosimetric impact due to the uncertainty of bolus placement is quantitatively evaluated and it is concluded that the use of hydrogel is an acceptable solution as compensation bolus with radiological properties similar to water. [Spanish] La incidencia de un campo de electrones en una superficie irregular produce distribuciones heterogéneas de dosis. En este trabajo se propone el uso de un bolus personalizado de hidrogel Varihesive® de ConvaTec para compensar dichas irregularidades. El hidrogel se caracteriza radiológicamente comparándolo con agua mediante una adquisición TC y se obtiene el porcentaje de dosis en profundidad para campos de electrones. Se evalúa cuantitativamente el impacto dosimétrico debido a la incertidumbre de colocación y se concluye que el uso de hidrogel resulta una solución aceptable como bolus de compensación con propiedades radiológicas similares al agua.

  12. Exploring Hydrofluorocarbons as Groundwater Age Tracers (Invited)

    Science.gov (United States)

    Haase, K. B.; Busenberg, E.; Plummer, L. N.; Casile, G.; Sanford, W. E.

    2013-12-01

    Groundwater dating tracers are an essential tool for analyzing hydrologic conditions in groundwater systems. Commonly used tracers for dating post-1940's groundwater include sulfur hexafluoride (SF6), chlorofluorocarbons (CFCs), 3H-3He, and other isotopic tracers (85Kr, δ2H and δ18O isotopes, etc.). Each tracer carries a corresponding set of advantages and limitations imposed by field, analytical, and interpretive methods. Increasing the number available tracers is appealing, particularly if they possess inert chemical properties and unique temporal emission histories from other tracers. Atmospherically derived halogenated trace gases continue to hold untapped potential for new tracers, as they are generally inert and their emission histories are well documented. SF5CF3, and CFC-13 were previously shown to have application as dating tracers, though their low mixing ratios and low solubility require large amounts of water to be degassed for their quantification. Two related groups of compounds, hydrochlorofluorocarbons (HCFCs) and hydrofluorocarbons (HFCs) are hypothesized to be potential age tracers, having similar mixing ratios to the CFCs and relatively high solubility. However, these compounds yield gas chromatography electron capture detector (GC-ECD) responses that are 10-2 -10-5 less than CFC-12, making purge and trap or field stripping GC-ECD approaches impractical. Therefore, in order to use dissolved HCFCs and HFCs as age tracers, different approaches are needed. To solve this problem, we developed an analytical method that uses an atomic emission detector (GC-AED) in place of an ECD to detect fluorinated compounds. In contrast to the ECD, the AED is a universally sensitive, highly linear, elementally specific detector. The new GC-AED system is being used to measure chlorodifluoromethane (HCFC-22), 1,1,1,2-tetrafluoroethane (HFC-134a), and other fluorinated compounds in one liter water samples to study their potential as age dating tracers. HCFC-22 is a

  13. Accuracy of pencil-beam redefinition algorithm dose calculations in patient-like cylindrical phantoms for bolus electron conformal therapy.

    Science.gov (United States)

    Carver, Robert L; Hogstrom, Kenneth R; Chu, Connel; Fields, Robert S; Sprunger, Conrad P

    2013-07-01

    The purpose of this study was to document the improved accuracy of the pencil beam redefinition algorithm (PBRA) compared to the pencil beam algorithm (PBA) for bolus electron conformal therapy using cylindrical patient phantoms based on patient computed tomography (CT) scans of retromolar trigone and nose cancer. PBRA and PBA electron dose calculations were compared with measured dose in retromolar trigone and nose phantoms both with and without bolus. For the bolus treatment plans, a radiation oncologist outlined a planning target volume (PTV) on the central axis slice of the CT scan for each phantom. A bolus was designed using the planning.decimal(®) (p.d) software (.decimal, Inc., Sanford, FL) to conform the 90% dose line to the distal surface of the PTV. Dose measurements were taken with thermoluminescent dosimeters placed into predrilled holes. The Pinnacle(3) (Philips Healthcare, Andover, MD) treatment planning system was used to calculate PBA dose distributions. The PBRA dose distributions were calculated with an in-house C++ program. In order to accurately account for the phantom materials a table correlating CT number to relative electron stopping and scattering powers was compiled and used for both PBA and PBRA dose calculations. Accuracy was determined by comparing differences in measured and calculated dose, as well as distance to agreement for each measurement point. The measured doses had an average precision of 0.9%. For the retromolar trigone phantom, the PBRA dose calculations had an average ± 1σ dose difference (calculated - measured) of -0.65% ± 1.62% without the bolus and -0.20% ± 1.54% with the bolus. The PBA dose calculation had an average dose difference of 0.19% ± 3.27% without the bolus and -0.05% ± 3.14% with the bolus. For the nose phantom, the PBRA dose calculations had an average dose difference of 0.50% ± 3.06% without bolus and -0.18% ± 1.22% with the bolus. The PBA dose calculations had an average dose difference of 0.65%

  14. The Impact of Injector-Based Contrast Agent Administration on Bolus Shape and Magnetic Resonance Angiography Image Quality.

    Science.gov (United States)

    Jost, Gregor; Endrikat, Jan; Pietsch, Hubertus

    2017-01-01

    To compare injector-based contrast agent (CA) administration with hand injection in magnetic resonance angiography (MRA). Gadobutrol was administered in 6 minipigs with 3 protocols: (a) hand injection (one senior technician), (b) hand injection (6 less-experienced technicians), and (c) power injector administration. The arterial bolus shape was quantified by test bolus measurements. A head and neck MRA was performed for quantitative and qualitative comparison of signal enhancement. A significantly shorter time to peak was observed for protocol C, whereas no significant differences between protocols were found for peak height and bolus width. However, for protocol C, these parameters showed a much lower variation. The MRA revealed a significantly higher signal-to-noise ratio for injector-based administration. A superimposed strong contrast of the jugular vein was found in 50% of the hand injections. Injector-based CA administration results in a more standardized bolus shape, a higher vascular contrast, and a more robust visualization of target vessels.

  15. Electrical characterization of bolus material as phantom for use in electrical impedance and computed tomography fusion imaging

    Directory of Open Access Journals (Sweden)

    Parvind Kaur Grewal

    2014-04-01

    Full Text Available Phantoms are widely used in medical imaging to predict image quality prior to clinical imaging. This paper discusses the possible use of bolus material, as a conductivity phantom, for validation and interpretation of electrical impedance tomography (EIT images. Bolus is commonly used in radiation therapy to mimic tissue. When irradiated, it has radiological characteristics similar to tissue. With increased research interest in CT/EIT fusion imaging there is a need to find a material which has both the absorption coefficient and electrical conductivity similar to biological tissues. In the present study the electrical properties, specifically resistivity, of various commercially available bolus materials were characterized by comparing their frequency response with that of in-vivo connective adipose tissue. It was determined that the resistivity of Gelatin Bolus is similar to in-vivo tissue in the frequency range 10 kHz to 1MHz and therefore has potential to be used in EIT/CT fusion imaging studies.

  16. Endothelial extraction of tracer water varies with extravascular water in dog lungs

    International Nuclear Information System (INIS)

    Chinard, F.P.; Cua, W.O.

    1987-01-01

    In multiple indicator-dilution experiments, transvascular passage of a permeating indicator is conventionally derived from the up-slope separation of the curve of the permeating indicator from that of a vascular reference and is expressed as the extraction (Ec). Extraction may be limited by the barrier (barrier-limited distribution). It may be limited by the volume of distribution accessible to it; in the time domain of an indicator-dilution experiment, the passage to and distribution in the extravascular volume are rapid relative to the velocity of blood in the exchange vessels. We examine here the relations of the extraction of tracer water as tritium oxide (THO) [Ec(THO)] and of the extraction of tracer sodium as 22Na [Ec(22Na)] to extravascular lung water, delta V wev, by adding isotonic fluid to the gas phase of the lungs. The net convective transvascular passage of water is negligible relative to the transendothelial molecular exchange. In 10 experiments in vivo and in 10 experiments in isolated perfused lungs, Ec(THO) increases as delta V wev increases. Ec(22Na) and the permeability-surface area product (PS) for 22Na do not change as delta V wev increases. We conclude that the extraction of THO is determined mainly by the volume accessible to it (flow- or volume-limited distribution) and that the extraction of 22Na is determined mainly by the resistance of the endothelium (barrier-limited distribution). A diffusion limitation in the added alveolar fluid rather than a barrier limitation at the endothelium may moderate Ec

  17. Quantitative determination of sediment movement at the landward spoil ground in the Yangtze Estuary with radioactive tracer

    International Nuclear Information System (INIS)

    Li Zhangsu

    1993-01-01

    A radioactive tracer experiment was carried out at the landward spoil ground of the North Passage in the Yangtze Estuary in June of 1991. The scandium-46 was selected as the tracer, the total activity released is 17.95 x 10 10 Bq(4.85 Ci), the amount of the scandium-46 glass is 495 g. The purpose of the experiment is to determine the sediment movement direction, path, velocity and transport rate. The experiment provides the direct evidence for using the landward spoil ground in the future. The experiment results show the sediment movement was governed by the ebb tide current during the period of middle and neap tides when the radioactive tracer was injected both on the flood and ebb tides, and the sediment moved from the injection points to the middle of the North Passage near the navigation buoy No. 269. The direction of the sediment movement is 110 degree, the particle velocity is 758 m/d, and the sediment transport rate per unit width is 47.8 m 3 /md

  18. Radioisotope tracers in industrial flow studies

    International Nuclear Information System (INIS)

    Easey, J.F.

    1987-01-01

    The scope of radioisotope tracer work carried out by ANSTO has involved most sectors of Australian industry including iron and steel coal, chemical, petrochemical, natural gas, metallurgical, mineral, power generation, liquified air plant, as well as port authorities, water and sewerage instrumentalities, and environmental agencies. A major class of such studies concerns itself with flow and wear studies involving industrial equipment. Some examples are discussed which illustrate the utility of radioisotope tracer techniques in these applications

  19. Development of a universal dual-bolus injection scheme for the quantitative assessment of myocardial perfusion cardiovascular magnetic resonance

    Directory of Open Access Journals (Sweden)

    Alfakih Khaled

    2011-05-01

    Full Text Available Abstract Background The dual-bolus protocol enables accurate quantification of myocardial blood flow (MBF by first-pass perfusion cardiovascular magnetic resonance (CMR. However, despite the advantages and increasing demand for the dual-bolus method for accurate quantification of MBF, thus far, it has not been widely used in the field of quantitative perfusion CMR. The main reasons for this are that the setup for the dual-bolus method is complex and requires a state-of-the-art injector and there is also a lack of post processing software. As a solution to one of these problems, we have devised a universal dual-bolus injection scheme for use in a clinical setting. The purpose of this study is to show the setup and feasibility of the universal dual-bolus injection scheme. Methods The universal dual-bolus injection scheme was tested using multiple combinations of different contrast agents, contrast agent dose, power injectors, perfusion sequences, and CMR scanners. This included 3 different contrast agents (Gd-DO3A-butrol, Gd-DTPA and Gd-DOTA, 4 different doses (0.025 mmol/kg, 0.05 mmol/kg, 0.075 mmol/kg and 0.1 mmol/kg, 2 different types of injectors (with and without "pause" function, 5 different sequences (turbo field echo (TFE, balanced TFE, k-space and time (k-t accelerated TFE, k-t accelerated balanced TFE, turbo fast low-angle shot and 3 different CMR scanners from 2 different manufacturers. The relation between the time width of dilute contrast agent bolus curve and cardiac output was obtained to determine the optimal predefined pause duration between dilute and neat contrast agent injection. Results 161 dual-bolus perfusion scans were performed. Three non-injector-related technical errors were observed (1.9%. No injector-related errors were observed. The dual-bolus scheme worked well in all the combinations of parameters if the optimal predefined pause was used. Linear regression analysis showed that the optimal duration for the predefined

  20. Improving Marine Ecosystem Models with Biochemical Tracers

    Science.gov (United States)

    Pethybridge, Heidi R.; Choy, C. Anela; Polovina, Jeffrey J.; Fulton, Elizabeth A.

    2018-01-01

    Empirical data on food web dynamics and predator-prey interactions underpin ecosystem models, which are increasingly used to support strategic management of marine resources. These data have traditionally derived from stomach content analysis, but new and complementary forms of ecological data are increasingly available from biochemical tracer techniques. Extensive opportunities exist to improve the empirical robustness of ecosystem models through the incorporation of biochemical tracer data and derived indices, an area that is rapidly expanding because of advances in analytical developments and sophisticated statistical techniques. Here, we explore the trophic information required by ecosystem model frameworks (species, individual, and size based) and match them to the most commonly used biochemical tracers (bulk tissue and compound-specific stable isotopes, fatty acids, and trace elements). Key quantitative parameters derived from biochemical tracers include estimates of diet composition, niche width, and trophic position. Biochemical tracers also provide powerful insight into the spatial and temporal variability of food web structure and the characterization of dominant basal and microbial food web groups. A major challenge in incorporating biochemical tracer data into ecosystem models is scale and data type mismatches, which can be overcome with greater knowledge exchange and numerical approaches that transform, integrate, and visualize data.

  1. Tracer monitoring of enhanced oil recovery projects

    Directory of Open Access Journals (Sweden)

    Kleven R.

    2013-05-01

    Full Text Available In enhanced oil recovery (EOR, chemicals are injected into the oil reservoir, either to increase macroscopic sweep efficiency, or to reduce remaining oil saturation in swept zones. Tracers can be used to identify reservoirs that are specifically suited for EOR operations. Injection of a selection of partitioning tracers, combined with frequent sample analysis of produced fluids, provides information suited for estimation of residual oil saturation. Tracers can also be used to evaluate and optimize the application of EOR chemicals in the reservoir. Suitable tracers will follow the EOR chemicals and assist in evaluation of retention, degradation or trapping. In addition to field applications, tracers also have a large potential as a tool to perform mechanistic studies of EOR chemicals in laboratory experiments. By labelling EOR chemicals with radioactive isotopes of elements such as H, C and S, detailed studies of transport mechanisms can be carried out. Co-injection of labelled compounds in dynamic flooding experiments in porous media will give information about retention or separation of the unique compounds constituting the chemical formulation. Separation of such compounds may be detrimental to obtaining the EOR effect expected. The paper gives new information of specific methods, and discusses current status for use of tracers in EOR operations.

  2. SU-F-T-325: On the Use of Bolus in Dosimetry and Dose Reduction for Pacemaker and Defibrillator

    International Nuclear Information System (INIS)

    Liu, W; Kenneth, R; Higgins, S; Nath, R; Zhu, D; Trumpore, S; Chen, Z

    2016-01-01

    Purpose: Special attention is required in planning and administering radiation therapy to patients with cardiac implantable electronic devices (CIEDs), such as pacemaker and defibrillator. The range of dose to CIEDs that can induce malfunction is very large among CIEDs. Significant defects have been reported at dose as low as 0.15Gy. Failures causing discomfort have been reported at dose as low as 0.05Gy. Therefore, accurate estimation of dose to CIED and dose reduction are both important even if the dose is expected to be less than the often-used 2Gy limit. We investigate the use of bolus in in vivo dosimetry for CIEDs. Methods: In our clinic, high-energy beams (>10MV) are not used for patients with CIED due to neutron production. Solid water phantom measurements of out-of-field dose for a 6MV beam were performed using parallel plate chamber at different depth with and without 2cm bolus covering the chamber. In vivo dosimetry at skin surface above the pacemaker was performed with and without bolus for 3 patients with pacemaker <5cm from the field edge. Results: Chamber measured dose at depth ∼1 to 1.5cm below the skin surface, where the CIED is normally located, was reduced by ∼6% – 20% with bolus. The dose reduction became smaller at deeper depth. In vivo dosimetry at skin surface also yielded ∼20% – 60% lower dose when using bolus for the 3 patients. In general, TPS calculation underestimated the dose. The dose measured with bolus is closer to the dose at the depth of the pacemaker and less affected by contaminant electrons and linac head leakage. Conclusion: In vivo CIED dose measurements should be performed with 1 to 2cm bolus covering the dosimeter on the skin above the CIED for more accurate CIED dose estimation. The use of bolus also reduces the dose delivered to CIED.

  3. SU-F-T-325: On the Use of Bolus in Dosimetry and Dose Reduction for Pacemaker and Defibrillator

    Energy Technology Data Exchange (ETDEWEB)

    Liu, W; Kenneth, R; Higgins, S; Nath, R [Yale University School of Medicine, New Haven, CT (United States); Zhu, D [Saint Thomas Hospital, Murfreesboro, TN (United States); Trumpore, S [Yale-New Haven Hospital, New Haven, CT (United States); Chen, Z [Yale New Haven Hospital, New Haven, CT (United States)

    2016-06-15

    Purpose: Special attention is required in planning and administering radiation therapy to patients with cardiac implantable electronic devices (CIEDs), such as pacemaker and defibrillator. The range of dose to CIEDs that can induce malfunction is very large among CIEDs. Significant defects have been reported at dose as low as 0.15Gy. Failures causing discomfort have been reported at dose as low as 0.05Gy. Therefore, accurate estimation of dose to CIED and dose reduction are both important even if the dose is expected to be less than the often-used 2Gy limit. We investigate the use of bolus in in vivo dosimetry for CIEDs. Methods: In our clinic, high-energy beams (>10MV) are not used for patients with CIED due to neutron production. Solid water phantom measurements of out-of-field dose for a 6MV beam were performed using parallel plate chamber at different depth with and without 2cm bolus covering the chamber. In vivo dosimetry at skin surface above the pacemaker was performed with and without bolus for 3 patients with pacemaker <5cm from the field edge. Results: Chamber measured dose at depth ∼1 to 1.5cm below the skin surface, where the CIED is normally located, was reduced by ∼6% – 20% with bolus. The dose reduction became smaller at deeper depth. In vivo dosimetry at skin surface also yielded ∼20% – 60% lower dose when using bolus for the 3 patients. In general, TPS calculation underestimated the dose. The dose measured with bolus is closer to the dose at the depth of the pacemaker and less affected by contaminant electrons and linac head leakage. Conclusion: In vivo CIED dose measurements should be performed with 1 to 2cm bolus covering the dosimeter on the skin above the CIED for more accurate CIED dose estimation. The use of bolus also reduces the dose delivered to CIED.

  4. Total intravenous anaesthesia by boluses or by continuous rate infusion of propofol in mute swans (Cygnus olor).

    Science.gov (United States)

    Müller, Kerstin; Holzapfel, Judith; Brunnberg, Leo

    2011-07-01

    To investigate intravenous (IV) propofol given by intermittent boluses or by continuous rate infusion (CRI) for anaesthesia in swans. Prospective randomized clinical study. Twenty mute swans (Cygnus olor) (eight immature and 12 adults) of unknown sex undergoing painless diagnostic or therapeutic procedures. Induction of anaesthesia was with 8 mg kg(-1) propofol IV. To maintain anaesthesia, ten birds (group BOLI) received propofol as boluses, whilst 10 (group CRI) received propofol as a CRI. Some physiological parameters were measured. Anaesthetic duration was 35 minutes. Groups were compared using Mann-Whitney U-test. Results are median (range). Anaesthetic induction was smooth and tracheal intubation was achieved easily in all birds. Bolus dose in group BOLI was 2.9 (1.3-4.3) mg kg(-1); interval between and number of boluses required were 4 (1-8) minutes and 6 (4-11) boluses respectively. Total dose of propofol was 19 (12.3-37.1) mg kg(-1). Awakening between boluses was very abrupt. In group CRI, propofol infusion rate was 0.85 (0.8-0.9) mg kg(-1) minute(-1), and anaesthesia was stable. Body temperature, heart and respiratory rates, oxygen saturation (by pulse oximeter) and reflexes did not differ between groups. Oxygen saturations (from pulse oximeter readings) were low in some birds. Following anaesthesia, all birds recovered within 40 minutes. In 55% of all, transient signs of central nervous system excitement occurred during recovery. 8 mg kg(-1) propofol appears an adequate induction dose for mute swans. For maintenance, a CRI of 0.85 mg kg(-1) minute(-1) produced stable anaesthesia suitable for painless clinical procedures. In contrast bolus administration, was unsatisfactory as birds awoke very suddenly, and the short intervals between bolus requirements hampered clinical procedures. Administration of additional oxygen throughout anaesthesia might reduce the incidence of low arterial haemoglobin saturation. © 2011 The Authors. Veterinary Anaesthesia and

  5. Evaluation of surface and shallow depth dose reductions using a Superflab bolus during conventional and advanced external beam radiotherapy.

    Science.gov (United States)

    Yoon, Jihyung; Xie, Yibo; Zhang, Rui

    2018-03-01

    The purpose of this study was to evaluate a methodology to reduce scatter and leakage radiations to patients' surface and shallow depths during conventional and advanced external beam radiotherapy. Superflab boluses of different thicknesses were placed on top of a stack of solid water phantoms, and the bolus effect on surface and shallow depth doses for both open and intensity-modulated radiotherapy (IMRT) beams was evaluated using thermoluminescent dosimeters and ion chamber measurements. Contralateral breast dose reduction caused by the bolus was evaluated by delivering clinical postmastectomy radiotherapy (PMRT) plans to an anthropomorphic phantom. For the solid water phantom measurements, surface dose reduction caused by the Superflab bolus was achieved only in out-of-field area and on the incident side of the beam, and the dose reduction increased with bolus thickness. The dose reduction caused by the bolus was more significant at closer distances from the beam. Most of the dose reductions occurred in the first 2-cm depth and stopped at 4-cm depth. For clinical PMRT treatment plans, surface dose reductions using a 1-cm Superflab bolus were up to 31% and 62% for volumetric-modulated arc therapy and 4-field IMRT, respectively, but there was no dose reduction for Tomotherapy. A Superflab bolus can be used to reduce surface and shallow depth doses during external beam radiotherapy when it is placed out of the beam and on the incident side of the beam. Although we only validated this dose reduction strategy for PMRT treatments, it is applicable to any external beam radiotherapy and can potentially reduce patients' risk of developing radiation-induced side effects. © 2018 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.

  6. Proceedings of a workshop on American Eel passage technologies

    Science.gov (United States)

    Haro, Alexander J.

    2013-01-01

    Recent concerns regarding a decline in recruitment of American eels (Anguilla rostrata) have prompted efforts to restore this species to historic habitats by providing passage for both upstream migrant juveniles and downstream migrant adults at riverine barriers, including low-head and hydroelectric dams (Castonguay et al. 1994, Haro et al. 2000). These efforts include development of management plans and stock assessment reviews in both the US and Canada (COSEWIC 2006, Canadian Eel Working Group 2009, DFO 2010, MacGregor et al. 2010, ASMFC 2000, ASMFC 2006, ASMFC 2008, Williams and Threader 2007), which target improvement of upstream and downstream passage for eels, as well as identification and prioritization of research needs for development of new and more effective passage technologies for American eels. Traditional upstream fish passage structures, such as fishways and fish lifts, are often ineffective passing juvenile eels, and specialized passage structures for this species are needed. Although designs for such passage structures are available and diverse (Knights and White 1998, Porcher 2002, FAO/DVWK 2002, Solomon and Beach 2004a,b, Environment Agency UK 2011), many biologists, managers, and engineers are unfamiliar with eel pass design and operation, or unaware of the technical options available for upstream eel passage, Better coordination is needed to account for eel passage requirements during restoration efforts for other diadromous fish species. Also, appropriately siting eel passes at hydropower projects is critical, and siting can be difficult and complex due to physical restrictions in access to points of natural concentrations of eels, dynamic hydraulics of tailrace areas, and presence of significant competing flows from turbine outfalls or spill. As a result, some constructed eel passes are sited poorly and may pass only a fraction of the number of eels attempting to pass the barrier. When sited and constructed appropriately, however, eel passes

  7. Functional aspects of distal oesophageal spasm: the role of onset velocity and contraction amplitude on bolus transit

    Science.gov (United States)

    Pohl, Daniel; Ciolino, Jody; Roberts, Jason; Savarino, Edoardo; Freeman, Janice; Nietert, Paul J; Tutuian, Radu; Castell, Donald

    2012-01-01

    Background Distal oesophageal spasm (DES) is a rare and under-investigated motility abnormality. Recent studies indicate effective bolus transit in varying percentages of DES patients. Aim Explore functional aspects including contraction onset velocity and contraction amplitude cut-off values for simultaneous contractions to predict complete bolus transit Methods We re-examined data from 107 impedance-manometry recordings with a diagnosis of DES. Receiver operating characteristic (ROC) analysis was conducted, regarding effects of onset velocity on bolus transit taking into account distal oesophageal amplitude (DEA) and correcting for intra-individual repeated measures. Results Mean area under the ROC curve for saline and viscous swallows were 0.84±0.05 and 0.84±0.04, respectively. Velocity criteria of >30cm/s when DEA>100mmHg and 8cm/s when DEADEA>100mmHg and >7cm/s when DEAsensitivity of 75% and specificity of 80% to identify complete bolus transit. Using these criteria, final diagnosis changed in 44.9% of patients. Abnormal bolus transit was observed in 50.9% of newly diagnosed DES patients versus 7.5% of patients classified as normal. DES patients with DEA>100mmHg suffered twice as often from chest pain than those with DEA<100mmHg. Conclusion The proposed velocity cut-offs for diagnosing distal oesophageal spasm improve the ability to identify patients with spasm and abnormal bolus transit. PMID:22475443

  8. Changes of the Specific Infectivity of Tracer Phages during Transport in Porous Media.

    Science.gov (United States)

    Ghanem, Nawras; Trost, Manuel; Sánchez Fontanet, Laura; Harms, Hauke; Chatzinotas, Antonis; Wick, Lukas Y

    2018-03-20

    Phages (i.e., viruses infecting bacteria) are considered to be good indicators and tracers for fecal pollution, hydraulic flow, or colloidal transport in the subsurface. They are typically quantified as total virus particles (VLP) or plaque forming units (PFU) of infectious phages. As transport may lead to phage deactivation, VLP quantification can overestimate the number of infectious phages. In contrast, PFU counts may underestimate the transport of total virus particles. Using PFU and tunable resistive pulse sensing-based counting for active and total phages, respectively, we quantified the effect of transport through laboratory percolation columns on the specific infectivity (SI). The SI is defined by the ratio of total VLP to PFU and is a measure for the minimum particle numbers needed to create a single infection. Transport of three marine tracer phages and the coli-phage (T4) was described by colloidal filtration theory. We found that apparent collision efficiencies of active and total phages differed. Depending on the phage properties (e.g., morphology or hydrophobicity), passage through a porous medium led to either an increasing or decreasing SI of effluent phages. Our data suggest that both phage mass recovery and the SI should be considered in quantitative phage tracer experiments.

  9. First passage Brownian functional properties of snowmelt dynamics

    Science.gov (United States)

    Dubey, Ashutosh; Bandyopadhyay, Malay

    2018-04-01

    In this paper, we model snow-melt dynamics in terms of a Brownian motion (BM) with purely time dependent drift and difusion and examine its first passage properties by suggesting and examining several Brownian functionals which characterize the lifetime and reactivity of such stochastic processes. We introduce several probability distribution functions (PDFs) associated with such time dependent BMs. For instance, for a BM with initial starting point x0, we derive analytical expressions for : (i) the PDF P(tf|x0) of the first passage time tf which specify the lifetime of such stochastic process, (ii) the PDF P(A|x0) of the area A till the first passage time and it provides us numerous valuable information about the total fresh water availability during melting, (iii) the PDF P(M) associated with the maximum size M of the BM process before the first passage time, and (iv) the joint PDF P(M; tm) of the maximum size M and its occurrence time tm before the first passage time. These P(M) and P(M; tm) are useful in determining the time of maximum fresh water availability and in calculating the total maximum amount of available fresh water. These PDFs are examined for the power law time dependent drift and diffusion which matches quite well with the available data of snowmelt dynamics.

  10. Kinetic modelling of [{sup 123}I]CNS 1261--a potential SPET tracer for the NMDA receptor

    Energy Technology Data Exchange (ETDEWEB)

    Erlandsson, Kjell E-mail: k.erlandsson@nucmed.ucl.ac.uk; Bressan, Rodrigo A.; Mulligan, Rachel S.; Gunn, Roger N; Cunningham, Vincent J.; Owens, Jonathan; Wyper, David; Ell, Peter J.; Pilowsky, Lyn S

    2003-05-01

    N-(1-napthyl)-N'-(3-[{sup 123}I]-iodophenyl)-N-methylguanidine ([{sup 123}I]CNS 1261) is a novel SPET ligand developed for imaging the NMDA receptor intra-channel MK 801/PCP/ketamine site. Data was acquired in 7 healthy volunteers after bolus injection of [{sup 123}I]CNS 1261. Kinetic modeling showed reversible tracer binding. Arterial and venous time-activity curves overlapped after 90 min. The rank order of binding was: Thalamus > striatum > cortical regions > white matter. This distribution concurs with [{sup 11}C]-ketamine and [{sup 18}F]-memantine PET studies . These data provide a methodological basis for further direct in vivo challenge studies.

  11. Double-tracer autoradiographic study of protein synthesis and glucose consumption in rats with focal cerebral ischemia

    DEFF Research Database (Denmark)

    Christensen, Thomas; Balchen, T; Bruhn, T

    1999-01-01

    A double-tracer autoradiographic method for simultaneous measurement of regional glucose utilization (rCMRglc) and regional protein synthesis (PS) in consecutive brain sections is described and applied to study the metabolism of the ischemic penumbra 2 h after occlusion of the middle cerebral...... artery (MCAO) in rats. In halothane anesthesia, the left middle cerebral artery was permanently occluded. Two hours after MCAO an i.v. bolus injection of 14C-deoxyglucose and 3H-leucine was given and circulated for 45 min. Two sets of brain sections were processed for quantitative autoradiography....... Neighboring brain sections exposed an X-ray film (3H-insensitive), and a 3H-sensitive for determination of rCMRglc and PS, respectively. Sections for PS determination were washed in trichloroacetic acid (TCA) prior to film exposure in order to remove 14C-deoxyglucose and unincorporated 3H-leucine. Regional...

  12. Proceedings of Tracer 3. International Conference on Tracers and Tracing Methods

    International Nuclear Information System (INIS)

    2004-01-01

    Tracer 3 conference is a continuation of former Tracer 1 (1998) and Tracer 2 (2001) conferences organized by CNRS - Nancy France. The objective of this 3rd conference is presentation of different aspects of tracer method applications and development of tracer methodology.The new field of activity presented at the Conference was application of stable isotopes as natural tracers for investigations of environmental processes. The conference gave the possibility for scientific information exchange between specialists from different fields of activity such as chemical engineering, chemistry, bioengineering, environmental engineering, hydrology, civil engineering, metallurgy, etc. The presentations were divided into groups covering the principal items of Conference. Section A. Fundamental development - RTD and tracer methodology, - RTD methodology and Computational Fluid Dynamics (CFD), - New tracers and detectors. Section B. Industrial applications - Environment, - Geology, hydrogeology and oil field applications, - Civil engineering, mineral engineering and metallurgy applications, - Food engineering and bioengineering, - Material engineering, - Chemical engineering. During the Conference INIS promotion materials were exposed by INIS liaison officer for Poland

  13. Proceedings of Tracer 3. International Conference on Tracers and Tracing Methods

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2004-07-01

    Tracer 3 conference is a continuation of former Tracer 1 (1998) and Tracer 2 (2001) conferences organized by CNRS - Nancy France. The objective of this 3rd conference is presentation of different aspects of tracer method applications and development of tracer methodology.The new field of activity presented at the Conference was application of stable isotopes as natural tracers for investigations of environmental processes. The conference gave the possibility for scientific information exchange between specialists from different fields of activity such as chemical engineering, chemistry, bioengineering, environmental engineering, hydrology, civil engineering, metallurgy, etc. The presentations were divided into groups covering the principal items of Conference. Section A. Fundamental development - RTD and tracer methodology, - RTD methodology and Computational Fluid Dynamics (CFD), - New tracers and detectors. Section B. Industrial applications - Environment, - Geology, hydrogeology and oil field applications, - Civil engineering, mineral engineering and metallurgy applications, - Food engineering and bioengineering, - Material engineering, - Chemical engineering. During the Conference INIS promotion materials were exposed by INIS liaison officer for Poland.

  14. Long residence times - bad tracer tests?

    Science.gov (United States)

    Ghergut, Julia; Behrens, Horst; Sauter, Martin

    2015-04-01

    Tracer tests conducted at geothermal well doublets or triplets in the Upper Rhine Rift Valley [1] all face, with very few exceptions so far, one common issue: lack of conclusive tracer test results, or tracer signals still undetectable for longer than one or two years after tracer injection. While the reasons for this surely differ from site to site (Riehen, Landau, Insheim, Bruchsal, ...), its effects on how the usefulness of tracer tests is perceived by the non-tracer community are pretty much the same. The 'poor-signal' frustration keeps nourishing two major 'alternative' endeavours : (I) design and execute tracer tests in single-well injection-withdrawal (push-pull), 'instead of' inter-well flow-path tracing configurations; (II) use 'novel' tracer substances instead of the 'old' ones which have 'obviously failed'. Frustration experienced with most inter-well tracer tests in the Upper Rhine Rift Valley has also made them be regarded as 'maybe useful for EGS' ('enhanced', or 'engineered' geothermal systems, whose fluid RTD typically include a major share of values below one year), but 'no longer worthwhile a follow-up sampling' in natural, large-scale hydrothermal reservoirs. We illustrate some of these arguments with the ongoing Bruchsal case [2]. The inter-well tracer test conducted at Bruchsal was (and still is!) aimed at assessing inter-well connectivity, fluid residence times, and characterizing the reservoir structure [3]. Fluid samples taken at the geothermal production well after reaching a fluid turnover of about 700,000 m3 showed tracer concentrations in the range of 10-8 Minj per m3, in the liquid phase of each sample (Minj being the total quantity of tracer injected as a short pulse at the geothermal re-injection well). Tracer signals might actually be higher, owing to tracer amounts co-precipitated and/or adsorbed onto the solid phase whose accumulation in the samples was unavoidable (due to pressure relief and degassing during the very sampling

  15. Esophagogastric junction outflow obstruction is often associated with coexistent abnormal esophageal body motility and abnormal bolus transit.

    Science.gov (United States)

    Zheng, E; Gideon, R M; Sloan, J; Katz, P O

    2017-10-01

    Currently, the diagnosis of esophageal motility disorders is in part based upon a hierarchical algorithm in which abnormalities of the esophagogastric junction (EGJ) is prioritized. An important metric in evaluating the EGJ is the integrated relaxation pressure (IRP). Patients who do not have achalasia but are found to have an elevated IRP are diagnosed with EGJ outflow obstruction. It has been our observation that a subset of these patients also has a second named motility disorder and may also have abnormal bolus transit. The aim of this study is to determine the frequency of abnormal body motility and or abnormal bolus movement in patients with EGJ outflow obstruction. Further, in an effort to evaluate the potential clinical value in measuring bolus transit as a complement to esophageal manometry, specifically in patients with EGJ outflow obstruction, we analyzed the presenting symptoms of these patients. A total of 807 patients with a mean age of 53 years completed esophageal function testing with impedance monitoring and high-resolution manometry between January 2012 and October 2016. There were 74 patients with achalasia who were excluded from the study. Of the remaining 733 patients, 138 (19%) had an elevated IRP and were given a diagnosis of EGJ outflow obstruction. Among these patients, 56 (40%) were diagnosed with an abnormal motility pattern to liquids (ineffective esophageal motility = 28, distal esophageal spasm = 19, Jackhammer = 6), of which 44 (76%) had abnormal bolus transit to liquids, viscous, or both. In contrast, there were 82 patients with EGJ outflow obstruction and normal esophageal motility, of which 33 (40%) had abnormal bolus transit. Patients with preserved esophageal motility and EGJ outflow obstruction were then evaluated. Of the 733 patients, 299 (40%) had intact esophageal motility. Of the 299 patients with normal esophageal motility, 56 patients had an elevated IRP, of which 16 (28%) had abnormal bolus transit. There were 243 (33

  16. Flow characteristics in nuclear steam turbine blade passage

    International Nuclear Information System (INIS)

    Ahn, H.J.; Yoon, W.H.; Kwon, S.B.

    1995-01-01

    The rapid expansion of condensable gas such as moist air or steam gives rise to nonequilibrium condensation. As a result of irreversibility of condensation process in the nuclear steam turbine blade passage, the entropy of the flow increases, and the efficiency of the turbine decreases. In the present study, in order to investigate the flow characteristics of moist air in two-dimensional turbine blade passage which is made from the configuration of the last stage tip section of the actual nuclear steam turbine moving blade, the static pressures along both pressure and suction sides of blade are measured by static pressure taps and the distribution of Mach number on both sides of the blade are obtained by using the measured static pressure. Also, the flow field is visualized by a Schlieren system. From the experimental results, the effects of the stagnation temperature and specific humidity on the flow properties in the two dimensional steam turbine blade passage are clearly identified

  17. TRACER - TRACING AND CONTROL OF ENGINEERING REQUIREMENTS

    Science.gov (United States)

    Turner, P. R.

    1994-01-01

    TRACER (Tracing and Control of Engineering Requirements) is a database/word processing system created to document and maintain the order of both requirements and descriptive material associated with an engineering project. A set of hierarchical documents are normally generated for a project whereby the requirements of the higher level documents levy requirements on the same level or lower level documents. Traditionally, the requirements are handled almost entirely by manual paper methods. The problem with a typical paper system, however, is that requirements written and changed continuously in different areas lead to misunderstandings and noncompliance. The purpose of TRACER is to automate the capture, tracing, reviewing, and managing of requirements for an engineering project. The engineering project still requires communications, negotiations, interactions, and iterations among people and organizations, but TRACER promotes succinct and precise identification and treatment of real requirements separate from the descriptive prose in a document. TRACER permits the documentation of an engineering project's requirements and progress in a logical, controllable, traceable manner. TRACER's attributes include the presentation of current requirements and status from any linked computer terminal and the ability to differentiate headers and descriptive material from the requirements. Related requirements can be linked and traced. The program also enables portions of documents to be printed, individual approval and release of requirements, and the tracing of requirements down into the equipment specification. Requirement "links" can be made "pending" and invisible to others until the pending link is made "binding". Individuals affected by linked requirements can be notified of significant changes with acknowledgement of the changes required. An unlimited number of documents can be created for a project and an ASCII import feature permits existing documents to be incorporated

  18. Tracers of air-sea gas exchange

    International Nuclear Information System (INIS)

    Liss, P.S.

    1988-01-01

    The flux of gas across the air-sea interface is determined by the product of the interfacial concentration difference driving the exchange and a rate constant, often termed the transfer velocity. The concentration-difference term is generally obtained by direct measurement, whereas more indirect approaches are required to estimate the transfer velocity and its variation as a function of controlling parameters such as wind and sea state. Radioactive tracers have proved particularly useful in the estimation of air-sea transfer velocities and, recently, stable purposeful tracers have also started to be used. In this paper the use of the following tracers to determine transfer velocities at the sea surface is discussed: natural and bomb-produced 14 C, dissolved oxygen, 222 Rn and sulphur hexafluoride. Other topics covered include the relation between transfer velocity and wind speed as deduced from tracer and wind-tunnel studies, and the discrepancy between transfer velocities determined by using tracers and from eddy correlation measurements in the atmosphere. (author)

  19. Automatic Bolus Tracking Versus Fixed Time-Delay Technique in Biphasic Multidetector Computed Tomography of the Abdomen

    International Nuclear Information System (INIS)

    Adibi, Atoosa; Shahbazi, Ali

    2014-01-01

    Bolus tracking can individualize time delay for the start of scans in spiral computed tomography (CT). We compared automatic bolus tracking method with fixed time-delay technique in biphasic contrast enhancement during multidetector CT of abdomen. Adult patients referred for spiral CT of the abdomen were randomized into two groups; in group 1, the arterial and portal phases of spiral scans were started 25 s and 55 s after the start of contrast material administration; in group 2, using the automatic bolus tracking software, repetitive monitoring scans were performed within the lumen of the descending aorta as the region of interest with the threshold of starting the diagnostic scans as 60 HU. The contrast enhancement of the aorta, liver, and spleen were compared between the groups. Forty-eight patients (23 males, 25 females, mean age=56.4±13.5 years) were included. The contrast enhancement of the aorta, liver, and spleen at the arterial phase was similar between the two groups (P>0.05). Regarding the portal phase, the aorta and spleen were more enhanced in the bolus-tracking group (P<0.001). The bolus tracking provided more homogeneous contrast enhancement among different patients than the fixed time-delay technique in the liver at portal phase, but not at the arterial phase. The automatic bolus-tracking method, results in higher contrast enhancement of the aorta and spleen at the portal phase, but has no effect on liver enhancement. However, bolus tracking is associated with reduced variability for liver enhancement among different patients

  20. Cardiac T1 mapping in congenital heart disease: bolus vs. infusion protocols for measurements of myocardial extracellular volume fraction.

    Science.gov (United States)

    Al-Wakeel-Marquard, Nadya; Rastin, Sanaz; Muench, Frédéric; O H-Ici, Darach; Yilmaz, Sevim; Berger, Felix; Kuehne, Titus; Messroghli, Daniel R

    2017-12-01

    Myocardial extracellular volume fraction (ECV) reflecting diffuse myocardial fibrosis can be measured with T1 mapping cardiovascular magnetic resonance (CMR) before and after the application of a gadolinium-based extracellular contrast agent. The equilibrium between blood and myocardium contrast concentration required for ECV measurements can be obtained with a primed contrast infusion (equilibrium contrast-CMR). We hypothesized that equilibrium can also be achieved with a single contrast bolus to accurately measure diffuse myocardial fibrosis in patients with congenital heart disease (CHD). Healthy controls (n = 17; median age 24.0 years) and patients with CHD (n = 19; 25.0 years) were prospectively enrolled. Using modified Look-Locker inversion recovery T1 mapping before, 15 min after bolus injection, and during constant infusion of gadolinium-DOTA, T1 values were obtained for blood pool and myocardium of the left ventricle (LV), the interventricular septum (IVS), and the right ventricle (RV) in a single midventricular plane in short axis or in transverse orientation. ECV of LV, IVS and RV by bolus-only and bolus-infusion correlated significantly in CHD patients (r = 0.94, 0.95, and 0.74; p < 0.01, respectively) and healthy controls (r = 0.96, 0.89, and 0.64; p < 0.05, respectively). Bland-Altman plots revealed no significant bias between the techniques for any of the analyzed regions. ECV of LV and RV myocardium measured by bolus-only T1 mapping agrees well with bolus-infusion measurements in patients with CHD. The use of a bolus-only approach facilitates the integration of ECV measurements into existing CMR imaging protocols, allowing for assessment of diffuse myocardial fibrosis in CHD in clinical routine.

  1. A prospective, randomized, blinded-endpoint, controlled study - continuous epidural infusion versus programmed intermittent epidural bolus in labor analgesia

    Directory of Open Access Journals (Sweden)

    Joana Nunes

    Full Text Available Abstract Background: There is evidence that administration of a programmed intermittent epidural bolus (PIEB compared to continuous epidural infusion (CEI leads to greater analgesia efficacy and maternal satisfaction with decreased anesthetic interventions. Methods: In this study, 166 women with viable pregnancies were included. After an epidural loading dose of 10 mL with Ropivacaine 0.16% plus Sufentanil 10 µg, parturient were randomly assigned to one of three regimens: A - Ropivacaine 0.15% plus Sufentanil 0.2 µg/mL solution as continuous epidural infusion (5 mL/h, beginning immediately after the initial bolus; B - Ropivacaine 0.1% plus Sufentanil 0.2 µg/mL as programmed intermittent epidural bolus and C - Same solution as group A as programmed intermittent epidural bolus. PIEB regimens were programmed as 10 mL/h starting 60 min after the initial bolus. Rescue boluses of 5 mL of the same solution were administered, with the infusion pump. We evaluated maternal satisfaction using a verbal numeric scale from 0 to 10. We also evaluated adverse, maternal and neonatal outcomes. Results: We analyzed 130 pregnants (A = 60; B = 33; C = 37. The median verbal numeric scale for maternal satisfaction was 8.8 in group A; 8.6 in group B and 8.6 in group C (p = 0.83. We found a higher caesarean delivery rate in group A (56.7%; p = 0.02. No differences in motor block, instrumental delivery rate and neonatal outcomes were observed. Conclusions: Maintenance of epidural analgesia with programmed intermittent epidural bolus is associated with a reduced incidence of caesarean delivery with equally high maternal satisfaction and no adverse outcomes.

  2. A prospective, randomized, blinded-endpoint, controlled study - continuous epidural infusion versus programmed intermittent epidural bolus in labor analgesia.

    Science.gov (United States)

    Nunes, Joana; Nunes, Sara; Veiga, Mariano; Cortez, Mara; Seifert, Isabel

    2016-01-01

    There is evidence that administration of a programmed intermittent epidural bolus (PIEB) compared to continuous epidural infusion (CEI) leads to greater analgesia efficacy and maternal satisfaction with decreased anesthetic interventions. In this study, 166 women with viable pregnancies were included. After an epidural loading dose of 10mL with Ropivacaine 0.16% plus Sufentanil 10μg, parturient were randomly assigned to one of three regimens: A - Ropivacaine 0.15% plus Sufentanil 0.2μg/mL solution as continuous epidural infusion (5mL/h, beginning immediately after the initial bolus); B - Ropivacaine 0.1% plus Sufentanil 0.2μg/mL as programmed intermittent epidural bolus and C - Same solution as group A as programmed intermittent epidural bolus. PIEB regimens were programmed as 10mL/h starting 60min after the initial bolus. Rescue boluses of 5mL of the same solution were administered, with the infusion pump. We evaluated maternal satisfaction using a verbal numeric scale from 0 to 10. We also evaluated adverse, maternal and neonatal outcomes. We analyzed 130 pregnants (A=60; B=33; C=37). The median verbal numeric scale for maternal satisfaction was 8.8 in group A; 8.6 in group B and 8.6 in group C (p=0.83). We found a higher caesarean delivery rate in group A (56.7%; p=0.02). No differences in motor block, instrumental delivery rate and neonatal outcomes were observed. Maintenance of epidural analgesia with programmed intermittent epidural bolus is associated with a reduced incidence of caesarean delivery with equally high maternal satisfaction and no adverse outcomes. Copyright © 2015 Sociedade Brasileira de Anestesiologia. Published by Elsevier Editora Ltda. All rights reserved.

  3. Passage times of asymmetric anomalous walks with multiple paths

    International Nuclear Information System (INIS)

    Caceres, Manuel O; Insua, G Liliana

    2005-01-01

    We investigate the transient and the long-time behaviour of asymmetric anomalous walks in heterogeneous media. Two types of disorder are worked out explicitly: weak and strong disorder; in addition, the occurrence of disordered multiple paths is considered. We calculate the first passage time distribution of the associated stochastic transport process. We discuss the occurrence of the crossover from a power law to an exponential decay for the long-time behaviour of the distribution of the first passage times of disordered biased walks

  4. FUNCTIONS OF VATA (BASED ON CHARAKA) A Passage from Vaatkalaakaleeyam.

    Science.gov (United States)

    Trivedi, A R

    1982-04-01

    The author has chosen 12(th) Chapter from the Sutra Sthana of this great epic containing 12,000 verses and passages which is replete with materials to revive the whole art of healing even if the whole medical literatures is lost. The passage puts in a nutshell the key role played by Vayu / Vata in the working of the tantra and yantra of the body. Though exploration of the humours is yet to be done by modern physiologists to explain the Ayurvedic Vata which is responsible to no less than 18 functions of the normal body mechanism.

  5. Coefficients of tracer transfer through membranes. Pt. 7

    Energy Technology Data Exchange (ETDEWEB)

    Dorabialska, A; Hawlicka, E; Plonka, A [Politechnika Lodzka (Poland)

    1974-01-01

    The doubled value of the tracer transfer coefficient in the self-diffusion process is equal to the sum of tracer transfer coefficients in the diffusion and interfusion processes. The fundamental phenomenological relation can be deduced for the coefficients of tracer transfer between two phases of electrolyte solutions spearated by a virtual boundary. Indeed, the doubled value of the tracer mobility in the self-diffusion experiment (no concentration gradient of the traced substance) is equal to the sum of the tracer mobilities in the diffusion (tracer movement along with the concentration gradient of the traced substance) and interfusion experiments (tracer movement against the concentration gradient of the traced substance). Thus the doubled value of the tracer transfer coefficient in the self-diffusion process should be equal to the sum of tracer transfer coefficients in the diffusion and interfusion processes. The experimental verification of that fundamental relation is presented.

  6. Amniotic fluid index predicts the relief of variable decelerations after amnioinfusion bolus.

    Science.gov (United States)

    Spong, C Y; McKindsey, F; Ross, M G

    1996-10-01

    Our purpose was to determine whether intrapartum amniotic fluid index before amnioinfusion can be used to predict response to therapeutic amnioinfusion. Intrapartum patients (n = 85) with repetitive variable decelerations in fetal heart rate that necessitated amnioinfusion (10 ml/min for 60 minutes) underwent determination of amniotic fluid index before and after bolus amnioinfusion. The fetal heart tracing was scored (scorer blinded to amniotic fluid index values) for number and characteristics of variable decelerations before and 1 hour after initiation of amnioinfusion. The amnioinfusion was considered successful if it resulted in a decrease of > or = 50% in total number of variable decelerations or a decrease of > or = 50% in the rate of atypical or severe variable decelerations after administration of the bolus. Spontaneous vaginal births before completion of administration of the bolus (n = 18) were excluded from analysis. The probability of success of amnioinfusion in relation to amniotic fluid index was analyzed with the chi(2) test for progressive sequence. The mean amniotic fluid index before amnioinfusion was 6.2 +/- 3.3 cm. An amniotic fluid index of amnioinfusion decreased with increasing amniotic fluid index before amnioinfusion (76% [16/21] when initial amniotic fluid index was 0 to 4 cm, 63% [17/27] when initial amniotic fluid index was 4 to 8 cm, 44% [7/16] when initial amniotic fluid index was 8 to 12 cm, and 33% [1/3] when initial amniotic fluid index was > 12 cm, p = 0.03). The incidence of nuchal cords or true umbilical cord knots increased in relation to amniotic fluid index before amnioinfusion. Amniotic fluid index before amnioinfusion can be used to predict the success of amnioinfusion for relief of variable decelerations in fetal heart rate. Failure of amnioinfusion at a high amniotic fluid index before amnioinfusion may be explained by the increased prevalence of nuchal cords or true knots in the umbilical cord.

  7. INFLUENCE OF AGE ON SWALLOWS OF A HIGHLY VISCOUS LIQUID BOLUS

    Directory of Open Access Journals (Sweden)

    Weslania Viviane NASCIMENTO

    2015-03-01

    Full Text Available Background Swallow function has a decline with aging, mainly in those over 80 years old. In the population over 69 years, about 11% of subjects reported symptoms indicative of significant dysphagia. Objectives Our objective was to evaluate the hypothesis that older asymptomatic subjects before 80 years old have compensations to sustain a safe and efficient swallow, at least with swallows of liquid bolus. Methods We performed videofluoroscopic evaluation of swallows in 55 normal volunteers, a younger group with 33 subjects (16 men and 17 women aged 19 to 55 years, mean 35.5±9.8 years, and an older group with 22 subjects (15 men and 7 women aged 56 to 77 years, mean 64.8±6.8 years. The subjects swallowed in duplicate 5 mL and 10 mL of liquid barium with a pH of 7.9, density of 1.82 g/cm3, and viscosity of 895 cp. Results The mean duration of pharyngeal transit, pharyngeal clearance, upper esophageal sphincter opening, hyoid movement and oral-pharyngeal transit were longer in the younger group compared with the older group. The relation between pharyngeal clearance duration and hyoid movement duration was similar in younger and older subjects, for 5 mL and 10 mL bolus volumes. Conclusions On average, a highly viscous liquid bolus crosses the pharynx faster in older subjects (56-77 years old than in younger subjects (19-55 years old, which suggested an adaptation to the aging process to maintain a safe swallow.

  8. The effect of food bolus location on jaw movement smoothness and masticatory efficiency.

    Science.gov (United States)

    Molenaar, W N B; Gezelle Meerburg, P J; Luraschi, J; Whittle, T; Schimmel, M; Lobbezoo, F; Peck, C C; Murray, G M; Minami, I

    2012-09-01

    Masticatory efficiency in individuals with extensive tooth loss has been widely discussed. However, little is known about jaw movement smoothness during chewing and the effect of differences in food bolus location on movement smoothness and masticatory efficiency. The aim of this study was to determine whether experimental differences in food bolus location (anterior versus posterior) had an effect on masticatory efficiency and jaw movement smoothness. Jaw movement smoothness was evaluated by measuring jerk-cost (calculated from acceleration) with an accelerometer that was attached to the skin of the mentum of 10 asymptomatic subjects, and acceleration was recorded during chewing on two-colour chewing gum, which was used to assessed masticatory efficiency. Chewing was performed under two conditions: posterior chewing (chewing on molars and premolars only) and anterior chewing (chewing on canine and first premolar teeth only). Jerk-cost and masticatory efficiency (calculated as the ratio of unmixed azure colour to the total area of gum, the unmixed fraction) were compared between anterior and posterior chewing with the Wilcoxon signed rank test (two-tailed). Subjects chewed significantly less efficiently during anterior chewing than during posterior chewing (P = 0·0051). There was no significant difference in jerk-cost between anterior and posterior conditions in the opening phase (P = 0·25), or closing phase (P = 0·42). This is the first characterisation of the effect of food bolus location on jaw movement smoothness at the same time as recording masticatory efficiency. The data suggest that anterior chewing decreases masticatory efficiency, but does not influence jerk-cost. © 2012 Blackwell Publishing Ltd.

  9. Differential Response Pattern of Oropharyngeal Pressure by Bolus and Dry Swallows.

    Science.gov (United States)

    Hasegawa, Mana; Kurose, Masayuki; Okamoto, Keiichiro; Yamada, Yoshiaki; Tsujimura, Takanori; Inoue, Makoto; Sato, Taisuke; Narumi, Takatsune; Fujii, Noritaka; Yamamura, Kensuke

    2018-02-01

    The aim of this study was to determine if bolus and dry swallow showed similar pressure changes in the oropharynx using our newly developed device. A unique character of it includes that baropressure can be measured with the sensor being placed in the balloon and can assess the swallowing mechanics in terms of pressure changes in the oropharynx with less influences of direct contacts of boluses and oropharyngeal structures during swallow indirectly. Fifteen healthy subjects swallowed saliva (dry), 15 ml of water, 45 ml of water, and 15 ml of two different types of food in terms of viscosity (potage soup-type and mayonnaise-type foods). Suprahyoid muscle activity was recorded simultaneously. Three parameters, area under the curve (AUC), peak amplitude, and duration of pressure, were analyzed from each swallow. Almost all of the bolus swallowing events had biphasic baropressure responses consisting of an early phase and late phase (99%), whereas 90% of the saliva swallowing events had a single phase. AUC, peak, and duration displayed greater effects during the late phase than during the early phase. Baropressure of the early phase, but not of the late phase, significantly increased with increasing volume; however, small but significant viscosity effects on pressure were seen during both phases. Peak pressure of the late phase was preceded by maximum muscle activity, whereas that of the early phase was seen when muscle activity displayed a peak response. These findings indicated that our device with the ability to measure baropressure has the potential to provide additional parameter to assess the swallow physiology, and biphasic baropressure responses in the early and late phases could reflect functional aspects of the swallowing reflexes.

  10. Simulation and interpretation of inter-well tracer tests

    Directory of Open Access Journals (Sweden)

    Dugstad Øyvind

    2013-05-01

    Full Text Available In inter-well tracer tests (IWTT, chemical compounds or radioactive isotopes are used to label injection water and gas to establish well connections and fluid patterns in petroleum reservoirs. Tracer simulation is an invaluable tool to ease the interpretation of IWTT results and is also required for assisted history matching application of tracer data. In this paper we present a new simulation technique to analyse and interpret tracer results. Laboratory results are used to establish and test formulations of the tracer conservation equations, and the technique is used to provide simulated tracer responses that are compared with observed tracer data from an extensive tracer program. The implemented tracer simulation methodology use a fast post-processing of previously simulated reservoir simulation runs. This provides a fast, flexible and powerful method for analysing gas tracer behaviour in reservoirs. We show that simulation time for tracers can be reduced by factor 100 compared to solving the tracer flow equations simultaneously with the reservoir fluid flow equations. The post-processing technique, combined with a flexible built-in local tracer-grid refinement is exploited to reduce numerical smearing, particularly severe for narrow tracer pulses.

  11. Enhanced Oil Recovery: Aqueous Flow Tracer Measurement

    Energy Technology Data Exchange (ETDEWEB)

    Joseph Rovani; John Schabron

    2009-02-01

    A low detection limit analytical method was developed to measure a suite of benzoic acid and fluorinated benzoic acid compounds intended for use as tracers for enhanced oil recovery operations. Although the new high performance liquid chromatography separation successfully measured the tracers in an aqueous matrix at low part per billion levels, the low detection limits could not be achieved in oil field water due to interference problems with the hydrocarbon-saturated water using the system's UV detector. Commercial instrument vendors were contacted in an effort to determine if mass spectrometry could be used as an alternate detection technique. The results of their work demonstrate that low part per billion analysis of the tracer compounds in oil field water could be achieved using ultra performance liquid chromatography mass spectrometry.

  12. Biological tracer for waste site characterization

    International Nuclear Information System (INIS)

    Strong-Gunderson, J.

    1995-01-01

    Remediating hazardous waste sites requires detailed site characterization. In groundwater remediation, characterizing the flow paths and velocity is a major objective. Various tracers have been used for measuring groundwater velocity and transport of contaminants, colloidal particles, and bacteria and nutrients. The conventional techniques use dissolved solutes, dyes. and gases to estimate subsurface transport pathways. These tracers can provide information on transport and diffusion into the matrix, but their estimates for groundwater flow through fractured regions are very conservative. Also, they do not have the same transport characteristics as bacteria and suspended colloid tracers, both of which must be characterized for effective in-place remediation. Bioremediation requires understanding bacterial transport and nutrient distribution throughout the acquifer, knowledge of contaminants s mobile colloidal particles is just essential

  13. Optimum bolus wizard settings in insulin pumps in children with Type 1 diabetes

    DEFF Research Database (Denmark)

    Andersen, A J B; Ostenfeld, A; Pipper, C B

    2016-01-01

    : Optimum insulin pump settings at pump initiation depend on both insulin requirements and use of the pump. Settings need to be individualized because the standardized calculation factors are not constant for children. There is a need to develop specific age- and insulin dose-dependent calculation factors.......AIM: To evaluate current insulin pump settings in an optimally regulated paediatric population using bolus wizard. METHODS: We used a retrospective study design to analyse data from 124 children on insulin pump therapy who had optimum HbA1c levels [

  14. Test determination with tritium as a radioactive tracer of the residence time distribution in the stability pool for Cabrero sewage

    International Nuclear Information System (INIS)

    Diaz, Francisco; Duran, Oscar; Henriquez, Pedro; Vega, Pedro; Padilla, Liliana; Gonzalez, David; Garcia Agudo, Edmundo

    2000-01-01

    This work was prepared by the Chilean and International Atomic Energy Agencies and covers the hydrodynamic functioning of sewage stability pools using tracers. The plant selected in the city of Cabrero, 500 km. south of Santiago, and is a rectangular facultative pool with a surface area of 7100 m 2 and a maximum volume of 12,327 m2 that receives an average flow of 20 l/s, serving a population of 7000 individuals. The work aims to characterize the runoff from the flow that enters the pool, using a radioactive tracer test, where the incoming water is marked, and its out-coming passage is determined, to establish the residence time distribution. Tritium was selected in the form of tritiated water as a tracer that is precisely emptied into the water flow from the distribution ravine at the lake entrance. Samples are taken at the outflow to determine the concentration of tritium after distillation, simultaneously measuring the flow, to be analyzed in a liquid flicker counter. An average test time of 5.3 days was obtained and an analysis of the residence time distribution for the tracer shows that it leaves quickly and indicates bad flow distribution in the lake with a major short circuit and probable dead zones

  15. Use of radioactive tracers in dynamic sedimentology

    International Nuclear Information System (INIS)

    Tola, Francois.

    1982-01-01

    In the first part, developments in the use of radioactive tracers in sedimentology are recalled together with the corresponding fields of application and the identities of the main users. The state-of-the-art in France is also discussed; The main characteristics of the method are then described and compared with those of more classical methods. The results that can be obtained with tracer methods are then outlined. The criteria employed to establish the granulometry characteristics of the tracer, the particular radioisotope to be used, and the masses and activities involved, are treated. A list is then given of the main isotopes available in France and their characteristics. The various different labelling techniques employed are studied together with their respective advantages and disadvantages. The special case of pelitic sediments is mentioned. The use of reduced model isotope generators, double labelling and applications to studies of the mud plug in the Gironde Estuary are also discussed. The methods and materials used for injecting and detecting tracers are described, emphasis being given to the economic factors associated with the use of radioactive tracers in sedimentology. The second part of the report contains two chapters: - studies of transport by driftage: presentation and analysis of results and the application of the Count Rate Balance method to obtain quantitative information on transport; - studies of in-suspension transport of fine sediments in the sea: the procedures adopted from the moment when the tracer is introduced up to the time when the results are analyzed and interpreted, enables the trajectories and mean velocities of the transported sediments to be determined together with their degree of dilution and their settling speeds and rates; it is also possible to investigate the evolution and horizontal dispersion of the sediments in this way. Results from recent experiments are presented in both parts of the report

  16. Tracer applications in oil reservoirs in Brazil

    International Nuclear Information System (INIS)

    Moreira, R.M.; Ferreira Pinto, A.M.

    2004-01-01

    Radiotracer applications in oil reservoirs in Brazil started in 1997 at the request of the State Oil Company (Petrobras) at the Carmoplois oilfield. 1 Ci of HTO was injected in a regular five-spot plot and the results obtained were quite satisfactory. Shortly after this test one other request asked for distinguishing the contribution of different injection wells to a production well. It was then realized that other tracers should be available. As a first choice 35 SCN - has been selected since it could be produced at CDTN. An alternative synthesis path was defined which shortened post-irradiation manipulations. The tracer was tested in core samples and a field injection, simultaneously with HTO, was carried out at the Buracica field; again the HTO performed well but 35 SCN - showed up well ahead. Presently the HTO applications are being done on a routine basis. All in all, four tests were performed (some are still ongoing), and the detection limits for both 3 H and 35 S were optimized by refining the sample preparation stage. Lanthanide complexes used as activable tracers are also an appealing option, however core tests performed so far with La-, Ce- and Eu-EDTA indicated some delay of the tracer, so other complexants such as DOTA are to be tried in further laboratory tests and in a field application. Thus, a deeper understanding of their complexation chemistry and carefully conducted tests must be performed before lanthanide complexes can be qualified as reliable oil reservoir tracers. More recently, Petrobras has been asking for partitioning tracers intended for SOR measurement

  17. Geologic flow characterization using tracer techniques

    International Nuclear Information System (INIS)

    Klett, R.D.; Tyner, C.E.; Hertel, E.S. Jr.

    1981-04-01

    A new tracer flow-test system has been developed for in situ characterization of geologic formations. This report describes two sets of test equipment: one portable and one for testing in deep formations. Equations are derived for in situ detector calibration, raw data reduction, and flow logging. Data analysis techniques are presented for computing porosity and permeability in unconfined isotropic media, and porosity, permeability and fracture characteristics in media with confined or unconfined two-dimensional flow. The effects of tracer pulse spreading due to divergence, dispersion, and porous formations are also included

  18. SIMULASI JARINGAN KOMPUTER MENGGUNAKAN CISCO PACKET TRACER

    Directory of Open Access Journals (Sweden)

    M Mufadhol

    2012-01-01

    Full Text Available Perkembangan jaringan komputer saat ini begitu pesat, monitoring jaringan komputer akan menjadi suatu hal yang sulit dan rumit. Koneksi jaringan komputer merupakan suatu hal yang mendasar dalam suatu jaringan, karena bila koneksi itu bermasalah maka semua jenis aplikasi yang dijalankan melalui jaringan komputer tidak dapat digunakan. Cisco packet tracer dapat digunakan untuk simulasi yang mencerminkan arsitektur dan juga model dari jaringan komputer pada sistem jaringan yang digunakan. Dengan menggunakan aplikasi cisco packet tracer, simulasi mengenai jaringan dapat dimanfaatkan menjadi informasi tentang keadaan koneksi komputer dalam suatu jaringan.

  19. Selection of tracers for oil and gas evaluation

    International Nuclear Information System (INIS)

    Bjoernstad, T.

    1991-08-01

    The importance of tracer tests in reservoir descriptions is increasingly acknowledged by reservoir engineers as a method to obtain valuable dynamic information from the reservoir. The report describes the ''state-of-the art'' on tracer technology for interwell investigations. Experiences gained from a number of reported field tracer tests are reviewed, and results from detailed laboratory investigations on the static and dynamic behavior of various tracer molecules are discussed. A critical evaluation of the applicability of the various identified tracers is provided. Present and future trends in the development of tracer technology for reservoir description are sketched. 64 refs., 12 figs., 2 tabs

  20. SU-F-T-442: Dose Distribution Comparison for Post-Laryngectomy Stoma Area Between Conventional AP and VMAT Plans with Or Without Bolus

    Energy Technology Data Exchange (ETDEWEB)

    Lee, B [University of California, Los Angeles, Los Angeles, CA (United States); Zhang, J; Cho-Lim, J [VA Long Beach Healthcare System, Long Beach, CA (United States); University of California, Irvine, Orange, CA (United States); Leu, M [VA Greater Los Angeles Healthcare System, Los Angeles, CA (United States); Inouye, W [VA Long Beach Healthcare System, Long Beach, CA (United States); Lorentz, W [University of California, Los Angeles, Los Angeles, CA (United States); VA Greater Los Angeles Healthcare System, Los Angeles, CA (United States); Lee, S [University of California, Los Angeles, Los Angeles, CA (United States); VA Long Beach Healthcare System, Long Beach, CA (United States); VA Greater Los Angeles Healthcare System, Los Angeles, CA (United States)

    2016-06-15

    Purpose: To compare dose distributions of conventional AP vs. VMAT treatment plans with or without bolus around post-laryngectomy stoma. Methods: Radiation dose coverage for post-laryngectomy stoma was analyzed using a set of real-case CT-simulation images. After meticulous contouring of the catheter cuff, stoma lumen, peri-stoma skin and subclinical tumor bed at the larynx, the resulting dosimetry plans were analyzed with or without a 5 mm bolus placement. Wet gauze was used to minimize the effect of any air gap. Four plans were generated: AP superclavicular (SCV) plan with or without bolus, and VMAT plan with or without bolus. A dose of 60Gy in 30 fractions was prescribed at 3 cm depth for AP SCV plan, and to 95% of the PTV volume for VMAT plan. Results: For the conventional AP SCV plan, the peri-stoma skin dose is sensitive to bolus placement as well as air gap compensation by wetted gauze (V95% of 20.7%, 33.0% and 94.8% for no bolus, bolus without and with air gap compensation, respectively). For stoma lumen, the dose drops off rapidly in depth. The catheter cuff may have certain dose-buildup effect, but air gap around it and under the bolus placed can pose a more serious problem. The dose distributions of the two VMAT plans are moderately different for peri-stoma skin (V95% of 95.0% with bolus and air gap compensation, and 82.3% without bolus), but nearly identical for stoma lumen (V95% of 91.5% and 92.0%, respectively). VMAT allows beamlets with different angles of incidence that helped achieve such dose distribution around the stoma even without bolus placement. Conclusion: Overall, the dose coverage around the stoma in the VMAT plan is better than the conventional AP SCV plan. To achieve optimal dose distribution, it is still recommended to place physical bolus and reduce the air gaps.

  1. Evaluation of the Eclipse eMC algorithm for bolus electron conformal therapy using a standard verification dataset.

    Science.gov (United States)

    Carver, Robert L; Sprunger, Conrad P; Hogstrom, Kenneth R; Popple, Richard A; Antolak, John A

    2016-05-08

    The purpose of this study was to evaluate the accuracy and calculation speed of electron dose distributions calculated by the Eclipse electron Monte Carlo (eMC) algorithm for use with bolus electron conformal therapy (ECT). The recent com-mercial availability of bolus ECT technology requires further validation of the eMC dose calculation algorithm. eMC-calculated electron dose distributions for bolus ECT have been compared to previously measured TLD-dose points throughout patient-based cylindrical phantoms (retromolar trigone and nose), whose axial cross sections were based on the mid-PTV (planning treatment volume) CT anatomy. The phantoms consisted of SR4 muscle substitute, SR4 bone substitute, and air. The treatment plans were imported into the Eclipse treatment planning system, and electron dose distributions calculated using 1% and processors (Intel Xeon E5-2690, 2.9 GHz) on a framework agent server (FAS). In comparison, the eMC was significantly more accurate than the pencil beam algorithm (PBA). The eMC has comparable accuracy to the pencil beam redefinition algorithm (PBRA) used for bolus ECT planning and has acceptably low dose calculation times. The eMC accuracy decreased when smoothing was used in high-gradient dose regions. The eMC accuracy was consistent with that previously reported for accuracy of the eMC electron dose algorithm and shows that the algorithm is suitable for clinical implementation of bolus ECT.

  2. Planning Guide for Fish Passage at Pittsburgh District Dams

    Science.gov (United States)

    2013-08-01

    attracted to a downstream flow at the entrance gate of the lift. 2) Immigrants pass around a moveable crowder that, when engaged, forces fish into the...might influence fish passage over a large number of sites. REFERENCES Bailey, M. M., J. J. Isely, and W. C. Bridges , Jr. 2004. Movement and

  3. Nonstationary Narrow-Band Response and First-Passage Probability

    DEFF Research Database (Denmark)

    Krenk, Steen

    1979-01-01

    The notion of a nonstationary narrow-band stochastic process is introduced without reference to a frequency spectrum, and the joint distribution function of two consecutive maxima is approximated by use of an envelope. Based on these definitions the first passage problem is treated as a Markov po...

  4. Universality for first passage percolation on sparse random graphs

    NARCIS (Netherlands)

    Bhamidi, S.; Hofstad, van der R.W.; Hooghiemstra, G.

    2014-01-01

    We consider first passage percolation on the conguration model with n vertices, and general independent and identically distributed edge weights assumed to have a density. Assuming that the degree distribution satisfies a uniform X2 logX-condition, we analyze the asymptotic distribution for the

  5. Rites of passage and sustainable development in traditional Africa ...

    African Journals Online (AJOL)

    This study attempts to exhume the instrumentality of rites of passage with particular attention to puberty andmarriage rites in fostering and sustaining development. The study further proffers strategic choices for the retrieval of this integral part of African life for the moral development of the averageNigerian youth. The present ...

  6. First-Passage-Time Distribution for Variable-Diffusion Processes

    Science.gov (United States)

    Barney, Liberty; Gunaratne, Gemunu H.

    2017-05-01

    First-passage-time distribution, which presents the likelihood of a stock reaching a pre-specified price at a given time, is useful in establishing the value of financial instruments and in designing trading strategies. First-passage-time distribution for Wiener processes has a single peak, while that for stocks exhibits a notable second peak within a trading day. This feature has only been discussed sporadically—often dismissed as due to insufficient/incorrect data or circumvented by conversion to tick time—and to the best of our knowledge has not been explained in terms of the underlying stochastic process. It was shown previously that intra-day variations in the market can be modeled by a stochastic process containing two variable-diffusion processes (Hua et al. in, Physica A 419:221-233, 2015). We show here that the first-passage-time distribution of this two-stage variable-diffusion model does exhibit a behavior similar to the empirical observation. In addition, we find that an extended model incorporating overnight price fluctuations exhibits intra- and inter-day behavior similar to those of empirical first-passage-time distributions.

  7. readability of comprehension passages in junior high school (jhs)

    African Journals Online (AJOL)

    CHARLES

    ... to enhance readability. Key Words: readability formulas, comprehension passages, Junior High School, .... Index has a manual version but in this study the electronic version was used. The ..... probably the majority of the people heard the news by word of mouth. A critical look ..... The Journal of Tourism Studies 9.2: 49-60.

  8. Universality for first passage percolation on sparse random graphs

    NARCIS (Netherlands)

    Bhamidi, S.; Van Der Hofstad, R.W.; Hooghiemstra, G.

    2017-01-01

    We consider first passage percolation on the configuration model with n vertices, and general independent and identically distributed edge weights assumed to have a density. Assuming that the degree distribution satisfies a uniform X2 logX-condition, we analyze the asymptotic distribution for the

  9. Providing Aquatic Organism Passage in Vertically Unstable Streams

    Directory of Open Access Journals (Sweden)

    JanineM Castro

    2016-04-01

    Full Text Available Aquatic organism passage barriers have been identified as one of the key impediments to recovery of salmonids and other migratory aquatic organisms in the Pacific Northwest of the United States. As such, state and federal agencies invest millions of dollars annually to address passage barriers. Because many barriers function as ad hoc grade control structures, their removal and/or replacement can unwittingly set off a cascade of effects that can negatively impact the very habitat and passage that project proponents seek to improve. The resultant vertical instability can result in a suite of effects that range from floodplain disconnection and loss of backwater and side channel habitat, to increased levels of turbidity. Risk assessment, including an evaluation of both the stage of stream evolution and a longitudinal profile analysis, provides a framework for determining if grade control is warranted, and if so, what type of structure is most geomorphically appropriate. Potential structures include placement of large wood and roughness elements, and constructed riffles, step-pools, and cascades. The use of structure types that mimic natural reach scale geomorphic analogues should result in improved aquatic organism passage, increased structural resilience, and reduced maintenance.

  10. Enloe Dam Passage Project, Volume I, 1984 Annual Report.

    Energy Technology Data Exchange (ETDEWEB)

    Fanning, M.L.

    1985-07-01

    This report discusses issues related to the provision of fish passage facilities at Enloe Dam and the introduction of anadromous salmonid fish to the upper Similkameen River basin. The species of fish being considered is a summer run of steelhead trout adapted to the upper Columbia basin. (ACR)

  11. Passage of sediment through flumes and over weirs

    NARCIS (Netherlands)

    Bos, M.G.; Wijbenga, J.H.A.

    1997-01-01

    This paper reports on laboratory research on the sediment passage capability through long-throated flumes and broad-crested weirs with which the Froude number in the approach channel does not exceed 0.6 over a distance of about 20 times the water depth upstream of the structure. Design rules are

  12. Fire passage on geomorphic fractures in Cerrado: effect on vegetation

    Directory of Open Access Journals (Sweden)

    Otacílio Antunes Santana

    2017-01-01

    Full Text Available Geomorphic fracture is a natural geologic formation that sometimes forms a deep fissure in the rock with the establishment of soil and vegetation. The objective of this work was to analyze vegetation within geomorphic fractures under the effect of wildfire passage. The biometric variables evaluated before and after fire passage were: diameter, height, leaf area index, timber volume, grass biomass, number of trees and shrubs and of species. Results (in fractures were compared to adjacent areas (control. The effect of wildfire passage on vegetation within geomorphic fractures was not significant because fire followed plant biomass bed and when it met the fracture (wetter, it changed from soil surface to canopy surface (jump fire effect, affecting without significance the number of plants or species; so, fracture could be plants refuge against fire passage. We could infer in our experimental model that quality of plant biomass bed could be more significant than quantity, and microclimate variability recruits plants to the refuge (geomorphic fracture.

  13. Australian experience of fish passage past instream structures

    International Nuclear Information System (INIS)

    Lewis, B.

    2008-01-01

    The growth in hydropower has resulted in the construction of various structures across rivers and streams, such as dams and weirs, which may impede essential fish movements and result in local extinctions of some fish species. When it is not practical to build instream structures that provide for fish passage, it may be appropriate to install some type of fishway. Site specific factors such as the fish species present, topography, flow characteristics and cost effectiveness will determine how best to provide for fish passage. The types of fishways suitable at small dams and weirs up to five metres high were described in this paper along with their benefits and effectiveness. The purpose was to provide simple and appropriate solutions that can improve the health of rivers considerably by managing the native aquatic habitat. The upstream passage past obstacles can be provided for through several types of fishways such as pool-type fishways, Denil fish passes, rock ramps, nature-like bypass channels, fish lifts or locks, collection and transportation facilities. In addition to environmental benefits, providing for fish passage can have long term social and economic benefits as well. 17 refs., 3 figs

  14. First-passage percolation on the random graph

    NARCIS (Netherlands)

    Hofstad, van der R.W.; Hooghiemstra, G.; Van Mieghem, P.

    2001-01-01

    We study first-passage percolation on the random graph Gp(N) with exponentially distributed weights on the links. For the special case of the complete graph, this problem can be described in terms of a continuous-time Markov chain and recursive trees. The Markov chain X(t) describes the number of

  15. The influence of a slow-release multi-trace element ruminal bolus on trace element status, number of ovarian follicles and pregnancy outcomes in synchronized Afshari ewes

    Science.gov (United States)

    Abdollahi, E.; Kohram, H.; Shahir, M. H.; Nemati, M. H.

    2015-01-01

    Published data on the effects of ruminal bolus on the number of ovulatory follicles in ewes does not exist. The present study determined the effects of a ruminal bolus on trace element status, follicular dynamics and reproductive performance in ewes. Eighty Afshari cycling ewes were synchronized during breeding season using CIDR for 14 days and assigned to 4 groups (n=20); group 1 received a single Ferrobloc bolus four weeks prior to CIDR insertion following 400 IU eCG on CIDR removal, group 2 received two boluses four weeks prior to CIDR insertion following 400 IU eCG on CIDR removal, group 3 received only 400 IU eCG on CIDR removal and group 4 (control) received no bolus and no eCG. Transrectal ultrasonography was done to monitor the ovarian follicles on the day of CIDR removal and a day later. Results showed that boluses increased the status of copper, selenium and iodine on mating day and days 90 to 100 of gestation. Ruminal bolus did not significantly increase the number of different classes of ovarian follicles in ewes fed a diet meeting all trace mineral requirements. All ewes eventually became pregnant with 1 or 2 boluses but the multiple births rate (80%) was higher (P<0.05) after 2 boluses compared to the other groups. PMID:27175153

  16. Formation of Hyaline Cartilage Tissue by Passaged Human Osteoarthritic Chondrocytes.

    Science.gov (United States)

    Bianchi, Vanessa J; Weber, Joanna F; Waldman, Stephen D; Backstein, David; Kandel, Rita A

    2017-02-01

    When serially passaged in standard monolayer culture to expand cell number, articular chondrocytes lose their phenotype. This results in the formation of fibrocartilage when they are used clinically, thus limiting their use for cartilage repair therapies. Identifying a way to redifferentiate these cells in vitro is critical if they are to be used successfully. Transforming growth factor beta (TGFβ) family members are known to be crucial for regulating differentiation of fetal limb mesenchymal cells and mesenchymal stromal cells to chondrocytes. As passaged chondrocytes acquire a progenitor-like phenotype, the hypothesis of this study was that TGFβ supplementation will stimulate chondrocyte redifferentiation in vitro in serum-free three-dimensional (3D) culture. Human articular chondrocytes were serially passaged twice (P2) in monolayer culture. P2 cells were then placed in high-density (3D) culture on top of membranes (Millipore) and cultured for up to 6 weeks in chemically defined serum-free redifferentiation media (SFRM) in the presence or absence of TGFβ. The tissues were evaluated histologically, biochemically, by immunohistochemical staining, and biomechanically. Passaged human chondrocytes cultured in SFRM supplemented with 10 ng/mL TGFβ3 consistently formed a continuous layer of articular-like cartilage tissue rich in collagen type 2 and aggrecan and lacking collagen type 1 and X in the absence of a scaffold. The tissue developed a superficial zone characterized by expression of lubricin and clusterin with horizontally aligned collagen fibers. This study suggests that passaged human chondrocytes can be used to bioengineer a continuous layer of articular cartilage-like tissue in vitro scaffold free. Further study is required to evaluate their ability to repair cartilage defects in vivo.

  17. Contrast timing in computed tomography: Effect of different contrast media concentrations on bolus geometry

    International Nuclear Information System (INIS)

    Mahnken, Andreas H.; Jost, Gregor; Seidensticker, Peter; Kuhl, Christiane; Pietsch, Hubertus

    2012-01-01

    Objective: To assess the effect of low-osmolar, monomeric contrast media with different iodine concentrations on bolus shape in aortic CT angiography. Materials and methods: Repeated sequential computed tomography scanning of the descending aorta of eight beagle dogs (5 male, 12.7 ± 3.1 kg) was performed without table movement with a standardized CT scan protocol. Iopromide 300 (300 mg I/mL), iopromide 370 (370 mg I/mL) and iomeprol 400 (400 mg I/mL) were administered via a foreleg vein with an identical iodine delivery rate of 1.2 g I/s and a total iodine dose of 300 mg I/kg body weight. Time-enhancement curves were computed and analyzed. Results: Iopromide 300 showed the highest peak enhancement (445.2 ± 89.1 HU), steepest up-slope (104.2 ± 17.5 HU/s) and smallest full width at half maximum (FWHM; 5.8 ± 1.0 s). Peak enhancement, duration of FWHM, enhancement at FWHM and up-slope differed significantly between iopromide 300 and iomeprol 400 (p 0.05). Conclusions: Low viscous iopromide 300 results in a better defined bolus with a significantly higher peak enhancement, steeper up-slope and smaller FWHM when compared to iomeprol 400. These characteristics potentially affect contrast timing.

  18. Direct bolus imaging of cervical blood vessels by means of MRI

    International Nuclear Information System (INIS)

    Satoh, Toshihiko; Fujioka, Mutsuhisa; Watari, Tsutomu; Nishimura, Gen; Matsumoto, Toshihiko; Washiya, Sumio; Inoue, Kiyoshi; Horita, Masatoshi; Shimizu, Kohji.

    1991-01-01

    Direct bolus imaging (DBI) is one of the non-invasive method for flow measurements which is based on the bolus tracking technique. DBI permits the direct visualization of flow velocity profiles and vessel band width. We performed screening for cervical vessel disease in patients with vertigo by means of DBI. MR system used here was 0.5 T superconducting imager-SMT-50A (Shimazu Co. Ltd). Pulse sequence parameters were TR= 60 ms, TE= 50 ms, NEX= 1, acquisition matrix; 128 x 256, slice thickness= 5 mm, with cardiac gating. Pulse sequence employed a slice selective RF pulse at the level of C5 vertebral body to tag a disk of fluid perpendicular to the direction of flow, followed by a gradient reforcussed echo. We evaluated each peak high and band width of the common-carotid arteries and the vertebral arteries. Seventy nine of 83 cases had optimal examinations. Abnormal findings of DBI were seen in 15 of 79 cases, (including 2 of subclavian steal syndrome, 1 of carotid obstruction, 5 of vertebral obstruction, 1 of basilar artery obstruction, and 6 of hypoplasia of vertebral artery). The abnormal findings of DBI were well correlated with those of angiographic examinations. We concluded that DBI was suitable to the screening for cervical vessel diseases in patients with vertigo, and should be added to the routine MR studies. (author)

  19. Bolus effect to reduce skin dose of the caontralateral breast during breast cancer radiation therapy

    Energy Technology Data Exchange (ETDEWEB)

    Won, Young Jin [Dept. of Radiation Oncology, InJe University Ilsan Paik Hospital, Goyang (Korea, Republic of); Kim, Jong Won; Kim, Jung Hoon [Dept. of Radiology, Radiation Oncology, KonYang University Hospital, Daejeon (Korea, Republic of)

    2017-06-15

    The aim of this study was to evaluate the dose comparison using Radon phantom with 5 mm and 10 mm tissue equivalent materials, FIF, Wedge(15, 30 angle) and IMRT, to reduce the skin dose of the contralateral breast during breast cancer radiation therapy(Total dose: 50.4Gy). The dose was measured for each treatment plan by attaching to the 8 point of the contralateral breast of the treated region using a optical-stimulated luminance dosimeter(OSLD) as a comparative dose evaluation method. Of the OSLD used in the study, 10 were used with reproducibility within 3%. As a result, the average reduction rates of 5 mm and 10 mm in the FIF treatment plan were 37.23 cGy and 41.77 cGy, respectively, and the average reduction rates in the treatment plan using Wedge 15 degrees were 70.69 cGy and 87.57 cGy, respectively. The IMRT showed a reduction of 67.37 cGy and 83.17 cGy, respectively. The results of using bolus showed that as the thickness of the bolus increased in all treatments, the dose reduction increased. We concluded that mastectomy as well as general radiotherapy for breast cancer would be very effective for patients who are more likely to be exposed to scattered radiation due to a more demanding or complex treatment plan.

  20. The Effect of Bolus Volume on Hyoid Kinematics in Healthy Swallowing

    Directory of Open Access Journals (Sweden)

    Ahmed Nagy

    2014-01-01

    Full Text Available Hyoid movement in swallowing is biomechanically linked to closure of the laryngeal vestibule for airway protection and to opening of the upper esophageal sphincter. Studies suggest that the range of hyoid movement is highly variable in the healthy population. However, other aspects of hyoid movement such as velocity remain relatively unexplored. In this study, we analyze data from a sample of 20 healthy young participants (10 male to determine whether hyoid movement distance, duration, velocity, and peak velocity vary systematically with increases in thin liquid bolus volume from 5 to 20 mL. The temporal correspondence between peak hyoid velocity and laryngeal vestibule closure was also examined. The results show that maximum hyoid position and peak velocity increase significantly for 20 mL bolus volumes compared to smaller volumes, and that the timing of peak velocity is closely linked to achieving laryngeal vestibule closure. This suggests that generating hyoid movements with increased power is a strategy for handling larger volumes.

  1. Ocular dynamics of Garcinia cola (Heckel on healthy volunteers following bolus ingestion

    Directory of Open Access Journals (Sweden)

    S. A. Igwe

    2007-12-01

    Full Text Available Garcinia cola Heckel, an angiospermae belonging to the  family Guttiferae, is known in commerce as bitter cola. It is a plant found in the West African subregion, mostly in moist conditions, and often in association with Cola acuminata. The seeds are highly valued ingredients in African ethonomedicine. The seeds have several social uses and applications in folk medicine. These seeds are ordinarily chewed by the local people without prescription or restriction. In an in vivo case control study, the effects of Garcinia cola on some visual functions: pupil diameter, near point of convergence (NPC, amplitude of accommodation (AA, intraocular pressure (IOP, visual acuity (VA and habitual phoria; following bolus ingestion of 20 g was undertaken using healthy visually active volunteers. Results showed that bolus ingestion of Garcinia cola constricted the pupil by 68%, reduced the NPC by 28%, increased the AA by 17.8% at peak effect and decreased the intraocular pressure by 31% without affecting the distance and near VA. The lateral phoria at far and near tended towards esophoria. Possibly the miotic effect and reduction in IOP could be of benefit to patients with raised IOP where conventional drugs may not be effective. Also it is possible that the effects on phoria could be exploited in oculomotor function in combination with visual training.

  2. Study of the usefulness on liver CT using intermittent bolus injection method

    International Nuclear Information System (INIS)

    Hayashi, Hideo

    1990-01-01

    Usefulness on the liver CT using intermittent bolus injection method of contrast media (IM-CE) was studied in 108 hepatic space occupying lesions, particularly to analyze hepatocellular carcinoma (HCC). Scans were obtained before, 20∼30 (arterial phase) and 60 seconds (parenchymal phase) after intravenous bolus injection of 65%-diatrizoate (angiografin) or 300 mg I-iopamidol (iopamiron 300), and in case of necessity, added 3∼15 minutes (late phase) after all injections of contrast media. These scans imaging the features of hepatic mass provided us much useful information. Early enhancement of the arterial phase, and early wash out of the parenchymal phase and delayed ring enhancement of the capsule improved the rates of detection to 96%, 60%, and 49% respectively in case of HCC. Especially. at the small HCC (less than 2cm in diameter), these rates were 89%, 50%, and 28% respectively. Combination of these 3 findings suggested the possibility of HCC in comparison with other hepatic mass. The rate of accurate diagnosis of HCC by this IM-CE was 81%. Thus IM-CE CT provides the useful information in diagnosis of hepatic mass and should be considered as the routine examination of hepatic mass. (author)

  3. ANALGESIC EFFECT OF INTRATHECAL BACLOFEN BOLUS ON NEUROPATHIC PAIN IN SPINAL CORD INJURY PATIENTS.

    Science.gov (United States)

    Kumru, Hatice; Benito-Penalva, Jesus; Kofler, Markus; Vidal, Joan

    2018-05-18

    GABA-ergic neurons are widely distributed throughout the central nervous system, including the spinal cord which is important for the transmission of pain impulses to the brain. Here we hypothesized that intrathecal baclofen (ITB) which is a GABA analogue might exert analgesic effects on neuropathic pain, which could be related to subtypes of pain in spinal cord injury (SCI). SCI patients with a cervical or thoracic lesion and neuropathic pain were randomized to receive either a single ITB bolus or placebo. Numerical Rating Scale (NRS), Neuropathic Pain Symptom Inventory (NPSI), and Brief Pain Inventory (BPI) were obtained for assessment of neuropathic pain. Spasticity was assessed using Modified Ashworth Scale and visual analogue scale. Evaluations were performed at baseline, and 4, 8, and 24 hours after application of ITB or placebo. Eight patients received ITB, 5 placebo. Neuropathic pain improved significantly in the ITB group based on NRS, BPI, and NPSI, which revealed an effect on all subtypes of pain. Spasticity declined significantly. In the placebo group, there was neither significant change in pain nor in spasticity. An ITB bolus exerted a significant analgesic effect on all subtypes of neuropathic pain in SCI patients. ITB has analgesic effects on all subtypes of neuropathic pain and can improve interference of neuropathic pain with activities of daily living. ITB might be a promising analgesic treatment to control neuropathic pain. Copyright © 2018. Published by Elsevier Inc.

  4. Enteral nutrition for preterm infants: by bolus or continuous? An update

    Directory of Open Access Journals (Sweden)

    Valentina Bozzetti

    2017-06-01

    Full Text Available Optimization of nutritional management of preterm infants is crucial for achievement of their long-term health. Enteral nutrition is preferred to total parenteral nutrition (TPN because the former avoids complications related to vascular catheterization, sepsis, adverse effects of TPN, and fasting. Due to the lack of ability of preterm infants to coordinate suckling, swallowing, and breathing, tube feeding is necessary for most infants less than 1500 g to ensure sufficient feeding tolerance, to support optimal growth and to reduce the risk of aspiration. Therefore, feeding by orogastric or nasogastric tube using either continuous or intermittent bolus delivery of formula or human milk is common practice for these infants. Theoretical risks and benefits of both continuous nasogastric milk feeding and intermittent bolus milk feeding have been proposed. According to the literature, continuous nutrition could be preferred in smaller infants (as those with a birthweight below 1250 g or hemodynamically impaired infants; in stable growing infants nutrition can be administered intermittently as in healthy term infants.

  5. Evaluation of reconstruction parameters of electrical impedance tomography on aorta detection during saline bolus injection

    Directory of Open Access Journals (Sweden)

    Thürk Florian

    2016-09-01

    Full Text Available An accurate detection of anatomical structures in electrical impedance tomography (EIT is still at an early stage. Aorta detection in EIT is of special interest, since it would favor non-invasive assessment of hemodynamic processes in the body. Here, diverse EIT reconstruction parameters of the GREIT algorithm were systematically evaluated to detect the aorta after saline bolus injection in apnea. True aorta position and size were taken from computed tomography (CT. A comparison with CT showed that the smallest error for aorta displacement was attained for noise figure nf = 0.7, weighting radius rw = 0.15, and target size ts = 0.01. The spatial extension of the aorta was most precise for nf = 0.7, rw = 0.25, and ts = 0.07. Detection accuracy (F1-score was highest with nf = 0.6, rw = 0.15, and ts = 0.04. This work provides algorithm-related evidence for potentially accurate aorta detection in EIT after injection of a saline bolus.

  6. Bolus timing in high-pitch CT angiography of the aorta

    International Nuclear Information System (INIS)

    Beeres, Martin; Loch, Matthias; Schulz, Boris; Kerl, Matthias; Al-Butmeh, Firas; Bodelle, Boris; Herrmann, Eva; Gruber-Rouh, Tatjana; Lee, Clara; Jacobi, Volkmar; Vogl, Thomas J.

    2013-01-01

    Objective: To investigate the bolus geometry in high-pitch CT angiography (CTA) of the aorta without ECG synchronisation in comparison to single-source CT. Methods: Overall 160 consecutive patients underwent CTA either in conventional single-source mode with a pitch of 1.2 (group 1), or in dual-source mode with a pitch of 3.0 (groups 2, 3 and 4) using different contrast media timings with bolus triggering at 140 HU (5 s, group 1; 10 s, group 2; 12 s, group 3; 14 s, group 4). Contrast material, saline flush, flow rate and kV/mAs settings were kept equal for optimum comparability. Aortic attenuation was measured along the z-axis of the patient at different anatomic landmarks and subjective image quality was compared. Results: The most homogeneous enhancement of the aorta was reached with a delay of 10 s after reaching the trigger threshold. The imaging length was not significantly different, but the examination time was significantly (p < 0.001) shorter in the high-pitch group (7.7 s vs. 1.7 s for group 1 vs. 2, 3 and 4). Conclusion: In high-pitch CT angiography using a start delay of 10 s after a trigger threshold of 140 HU in the descending aorta is reached, a homogenous contrast along the z-axis is accomplished

  7. Transplacental passage of {sup 26}Al from pregnant rats to fetuses and {sup 26}Al transfer through maternal milk to suckling rats

    Energy Technology Data Exchange (ETDEWEB)

    Yumoto, S.; Nagai, H.; Matsuzaki, H.; Kobayashi, T.; Tada, W.; Ohki, Y.; Kakimi, S.; Kobayashi, K

    2000-10-01

    Aluminium (Al) is toxic to the growth of fetuses and sucklings. However, the incorporation of Al into fetuses and sucklings in the periods of gestation and lactation has not been well clarified because Al lacks a suitable isotope for a tracer experiment. In this study, we used {sup 26}Al (a radioisotope of Al with half-life of 716,000 yr) as a tracer, and measured {sup 26}Al incorporation into fetuses and sucklings by accelerator mass spectrometry (AMS). To investigate Al incorporation into fetuses through transplacental passage, {sup 26}Al ({sup 26}AlCl{sub 3}) was subcutaneously injected into pregnant rats on day 15 of gestation. {sup 26}Al was also subcutaneoulsy injected into lactating rats from day 1 to day 20 postpartum. By day 20 of gestation, 0.2% of the {sup 26}Al injected into a pregnant rat had been transferred to the fetuses, and {sup 26}Al was detected in the brain and liver of the fetuses. On day 9 postpartum, high levels of {sup 26}Al were demonstrated in the brain, liver, kidneys and blood of suckling rats. It is concluded that {sup 26}Al subcutaneously injected into pregnant rats and/or lactating rats is incorporated into their offspring through transplacental passage and/or maternal milk.

  8. Use of labeled compounds in tracer experiments

    International Nuclear Information System (INIS)

    Anon.

    1991-01-01

    The use of radiotracers in research has become common. This chapter looks at some of the underlying assumptions and advantages of labeled compounds: advantages of radiotracers; availability of suitable tracers and labeled compounds; purity of labeled compounds; autoradiolysis; storage of labeled compounds; detection systems for chromatography and electrophoretic methods. 14 refs., 2 figs

  9. Rate tracer studies of heterogeneous catalysis

    Energy Technology Data Exchange (ETDEWEB)

    Happel, J; Kiang, S

    1977-10-01

    An analysis is presented of the extent to which parameters involved in transient tracing of isotopic species in heterogeneous catalysis can be determined by experiments in which tracer concentrations are measured as a function of time. Different treatments for open and closed systems with the over-all reaction at equilibrium or irreversible were developed.

  10. Tracer dispersion in planar multipole flows

    International Nuclear Information System (INIS)

    Koplik, J.; Redner, S.; Hinch, E.J.

    1994-01-01

    We study the motion of passive Brownian tracer particles in steady two-dimensional potential flows between sources and sinks. Our primary focus is understanding the long-time properties of the transit time probability distribution for the tracer to reach the sink p(t) and the influence of the flow geometry on this probability. A variety of illustrative case studies is considered. For radial potential flow in an annular region, competition between convection and diffusion leads to nonuniversal decay of the transit time probability. Dipolar and higher multipole flows are found to exhibit generic features, such as a power-law decay in p(t) with an exponent determined by the multipole moment, an exponential cutoff related to stagnation points, and a ''shoulder'' in p(t) that is related to reflection from the system boundaries. For spatially extended sinks, it is also shown that the spatial distribution of the collected tracer is independent of the overall magnitude of the flow field and that p(t) decays as a power law with a geometry-dependent exponent. Our results may offer the possibility of using tracer measurements to characterize the flow geometry of porous media

  11. Nanoparticle tracers in calcium carbonate porous media

    KAUST Repository

    Li, Yan Vivian

    2014-07-15

    Tracers are perhaps the most direct way of diagnosing subsurface fluid flow pathways for ground water decontamination and for natural gas and oil production. Nanoparticle tracers could be particularly effective because they do not diffuse away from the fractures or channels where flow occurs and thus take much less time to travel between two points. In combination with a chemical tracer they can measure the degree of flow concentration. A prerequisite for tracer applications is that the particles are not retained in the porous media as the result of aggregation or sticking to mineral surfaces. By screening eight nanoparticles (3-100 nm in diameter) for retention when passed through calcium carbonate packed laboratory columns in artificial oil field brine solutions of variable ionic strength we show that the nanoparticles with the least retention are 3 nm in diameter, nearly uncharged, and decorated with highly hydrophilic polymeric ligands. The details of these column experiments and the tri-modal distribution of zeta potential of the calcite sand particles in the brine used in our tests suggests that parts of the calcite surface have positive zeta potential and the retention of negatively charged nanoparticles occurs at these sites. Only neutral nanoparticles are immune to at least some retention. © 2014 Springer Science+Business Media.

  12. Using neural networks to describe tracer correlations

    Directory of Open Access Journals (Sweden)

    D. J. Lary

    2004-01-01

    Full Text Available Neural networks are ideally suited to describe the spatial and temporal dependence of tracer-tracer correlations. The neural network performs well even in regions where the correlations are less compact and normally a family of correlation curves would be required. For example, the CH4-N2O correlation can be well described using a neural network trained with the latitude, pressure, time of year, and methane volume mixing ratio (v.m.r.. In this study a neural network using Quickprop learning and one hidden layer with eight nodes was able to reproduce the CH4-N2O correlation with a correlation coefficient between simulated and training values of 0.9995. Such an accurate representation of tracer-tracer correlations allows more use to be made of long-term datasets to constrain chemical models. Such as the dataset from the Halogen Occultation Experiment (HALOE which has continuously observed CH4  (but not N2O from 1991 till the present. The neural network Fortran code used is available for download.

  13. Using radioactive tracer technique in municipal hygiene

    International Nuclear Information System (INIS)

    Yurasova, O.I.

    1974-01-01

    Work of the A. N. Syrsin Institute of General and Municiapl Hygiene using raidoactive tracers is reviewed. The studies include research on protein metabolism in the living organism following action of unfavorable factors of the environment; determination of the paths of introduction into the organism of substances with an alien composition; and study of the rate of resorption of subcutaneous papuli. Results are shown of radioactive-tracer studies on the mechanism of action of poisonous substances on the living organism and of migration of alien chemical compounds in the organism and in objects in the environment. It is concluded that the radioactive tracer method has wide application in municipal hygiene and sanitary microbiology. The absence of laborious operations, economy of time, precision of the experiments, and the possibility of obtaining additional information on the mechanism of action of poisonous substances on the organism and the low cost of such studies compared with other methods makes the radioactive tracer method economically attractive. The studies made show the various types of use of the method in municipal hygiene and sanitary microbiology

  14. Hybrid tracers for sentinel node biopsy

    International Nuclear Information System (INIS)

    Van Den Berg, N. S.; Kleinjan, G. I.; Valdés-Olmos, R. A.; Buckle, T.; Van Leeuwen, F. I.; Klop, W. M.; Horenblas, S.; Van Der Poel, H. G.

    2014-01-01

    Conventional sentinel node (SN) mapping is performed by injection of a radiocolloid followed by lymphoscintigraphy to identify the number and location of the primary tumor draining lymph node(s), the so-called SN(s). Over the last decade research has focused on the introduction of new imaging agents that can further aid (surgical) SN identification. Different tracers for SN mapping, with varying sizes and isotopes have been reported, most of which have proven their value in a clinical setting. A major challenge lies in transferring this diagnostic information obtained at the nuclear medicine department to the operating theatre thereby providing the surgeon with (image) guidance. Conventionally, an intraoperative injection of vital blue dye or a fluorescence dye is given to allow intraoperative optical SN identification. However, for some indications, the radiotracer-based approach remains crucial. More recently, hybrid tracers, that contain both a radioactive and fluorescent label, were introduced to allow for direct integration of pre- and intraoperative guidance technologies. Their potential is especially high when they are used in combination with new surgical imaging modalities and navigation tools. Next to a description of the known tracers for SN mapping, this review discusses the application of hybrid tracers during SN biopsy and how the introduction of these new techniques can further aid in translation of nuclear medicine information into the operating theatre.

  15. Fractal tracer distributions in turbulent field theories

    DEFF Research Database (Denmark)

    Hansen, J. Lundbek; Bohr, Tomas

    1998-01-01

    We study the motion of passive tracers in a two-dimensional turbulent velocity field generated by the Kuramoto-Sivashinsky equation. By varying the direction of the velocity-vector with respect to the field-gradient we can continuously vary the two Lyapunov exponents for the particle motion and t...

  16. Suitability of tracers; Eignung von Tracern

    Energy Technology Data Exchange (ETDEWEB)

    Klotz, D. [GSF - Forschungszentrum fuer Umwelt und Gesundheit GmbH, Neuherberg (Germany). Inst. fuer Hydrologie

    1999-02-01

    Hydrological tracer techniques are a means of making statements on the direction and speed of underground water. One of the simpler tasks is to find out whether there is hydrological communication between two given points. This requires a determination of the direction of flow, which places less exacting demands on the properties of the tracer than does the task of determining the flow velocity of underground water. Tracer methods can serve to infer from flow velocity the distance (flow) velocity, which is defined as the ratio between the distance between two points located in flow direction and the actual time it takes water to flow from one to the other. [Deutsch] Mit Hilfe der hydrologischen Markierungstechniken koennen Aussagen ueber die Richtung und die Geschwindigkeit von Bewegungen des unterirdischen Wassers gemacht werden. Der einfachere Fall liegt vor, wenn festgestellt werden soll, ob zwischen zwei Punkten eine hydrologische Verbindung besteht. Bei dieser Fliessrichtungsbestimmung sind die Forderungen an die Eigenschaften der einzusetzenden Tracer geringer als bei der Bestimmung der Geschwindigkeit des unterirdischen Wassers. Von den Geschwindigkeiten des unterirdischen Wassers ist die Abstands-(Fliess)geschwindigkeit, die definiert ist durch das Verhaeltnis aus dem Abstand und der wahren Fliesszeit zwischen zwei in Bewegungsrichtung gelegenen Punkten, durch Tracermethoden zu bestimmen. (orig.)

  17. Using radioactive tracer technique in municipal hygiene

    Energy Technology Data Exchange (ETDEWEB)

    Yurasova, O I [Institut Obshchej i Kommunal' noj Gigieny, Moscow (USSR)

    1974-01-01

    Work of the A. N. Syrsin Institute of General and Municiapl Hygiene using raidoactive tracers is reviewed. The studies include research on protein metabolism in the living organism following action of unfavorable factors of the environment; determination of the paths of introduction into the organism of substances with an alien composition; and study of the rate of resorption of subcutaneous papuli. Results are shown of radioactive-tracer studies on the mechanism of action of poisonous substances on the living organism and of migration of alien chemical compounds in the organism and in objects in the environment. It is concluded that the radioactive tracer method has wide application in municipal hygiene and sanitary microbiology. The absence of laborious operations, economy of time, precision of the experiments, and the possibility of obtaining additional information on the mechanism of action of poisonous substances on the organism and the low cost of such studies compared with other methods makes the radioactive tracer method economically attractive. The studies made show the various types of use of the method in municipal hygiene and sanitary microbiology.

  18. Pipeline leak detection using volatile tracers

    International Nuclear Information System (INIS)

    Thompson, G.M.; Golding, R.D.

    1993-01-01

    A method of leak detection for underground storage tanks and pipelines adds volatile tracers to the products in the tanks and analyzes the surrounding shallow soil gases for tracer vapors. This method has several advantages: the success of the test is not limited by the size and structural design of the vessels, tanks can be tested at any fill level without taking the tank out of service, the location of a leak along a pipeline is clearly marked by the location of the tracer, and liquid leaks as small as 0.2 liters per hour (lph) can be detected. A limitation is: the backfill material must have some degree of air permeability in the zone above the water table. Several field tests document the success achieved using this method. A tracer leak detection system was installed at Homestead AFB after several other testing methods failed to locate a leak at a valve pit location along approximately 4 kilometers of fuel transfer piping. The leak was detected to the side of the valve pit at a depth of approximately 2.5 meters below the ground surface. Another installation of Edwards AFB involved the collection of 415 soil gas samples along approximately 3,050 meters of 15.25-centimeter fiberglass pipeline. Fourteen separate leaks were detected

  19. Halon-1301, a new Groundwater Age Tracer

    Science.gov (United States)

    Beyer, Monique; van der Raaij, Rob; Morgenstern, Uwe; Jackson, Bethanna

    2015-04-01

    Groundwater dating is an important tool to assess groundwater resources in regards to direction and time scale of groundwater flow and recharge and to assess contamination risks and manage remediation. To infer groundwater age information, a combination of different environmental tracers, such as tritium and SF6, are commonly used. However ambiguous age interpretations are often faced, due to a limited set of available tracers and limitations of each tracer method when applied alone. There is a need for additional, complementary groundwater age tracers. We recently discovered that Halon-1301, a water soluble and entirely anthropogenic gaseous substance, may be a promising candidate [Beyer et al, 2014]. Halon-1301 can be determined along with SF6, SF5CF3 and CFC-12 in groundwater using a gas chromatography setup with attached electron capture detector developed by Busenberg and Plummer [2008]. Halon-1301 has not been assessed in groundwater. This study assesses the behaviour of Halon-1301 in water and its suitability as a groundwater age tracer. We determined Halon-1301 in 17 groundwater and various modern (river) waters sites located in 3 different groundwater systems in the Wellington Region, New Zealand. These waters have been previously dated with tritium, CFC-12, CFC-11 and SF6 with mean residence times ranging from 0.5 to over 100 years. The waters range from oxic to anoxic and some show evidence of CFC contamination or degradation. This allows us to assess the different properties affecting the suitability of Halon-1301 as groundwater age tracer, such as its conservativeness in water and local contamination potential. The samples are analysed for Halon-1301 and SF6simultaneously, which allows identification of issues commonly faced when using gaseous tracers such as contamination with modern air during sampling. Overall we found in the assessed groundwater samples Halon-1301 is a feasible new groundwater tracer. No sample indicated significantly elevated

  20. Methods for conduct of atmospheric tracer studies at ANSTO

    Energy Technology Data Exchange (ETDEWEB)

    Clark, G H; Stone, D J.M.; Pascoe, J H [Australian Nuclear Science and Technology Organisation (ANSTO), Lucas Heights, NSW (Australia). Environment Division

    2000-07-01

    A perfluorocarbon atmospheric tracer system has been developed to investigate atmospheric dispersion processes in the region surrounding the Lucas Heights Science and Technology Centre. This report discusses the tracer release, sampling and analysis methods.

  1. Laplace transform in tracer kinetic modeling

    Energy Technology Data Exchange (ETDEWEB)

    Hauser, Eliete B., E-mail: eliete@pucrs.br [Instituto do Cerebro (InsCer/FAMAT/PUC-RS), Porto Alegre, RS, (Brazil). Faculdade de Matematica

    2013-07-01

    The main objective this paper is to quantify the pharmacokinetic processes: absorption, distribution and elimination of radiopharmaceutical(tracer), using Laplace transform method. When the drug is administered intravenously absorption is complete and is available in the bloodstream to be distributed throughout the whole body in all tissues and fluids, and to be eliminated. Mathematical modeling seeks to describe the processes of distribution and elimination through compartments, where distinct pools of tracer (spatial location or chemical state) are assigned to different compartments. A compartment model is described by a system of differential equations, where each equation represents the sum of all the transfer rates to and from a specific compartment. In this work a two-tissue irreversible compartment model is used for description of tracer, [{sup 18}F]2-fluor-2deoxy-D-glucose. In order to determine the parameters of the model, it is necessary to have information about the tracer delivery in the form of an input function representing the time-course of tracer concentration in arterial blood or plasma. We estimate the arterial input function in two stages and apply the Levenberg-Marquardt Method to solve nonlinear regressions. The transport of FDG across de arterial blood is very fast in the first ten minutes and then decreases slowly. We use de Heaviside function to represent this situation and this is the main contribution of this study. We apply the Laplace transform and the analytical solution for two-tissue irreversible compartment model is obtained. The only approach is to determinate de arterial input function. (author)

  2. Guidebook on radioisotope tracers in industry

    International Nuclear Information System (INIS)

    1990-01-01

    The idea of using tracers (chemical, dyes, etc.) in the investigation of complex physical phenomena has always attracted the attention of scientists and engineers. When radioactive isotopes became available it was immediately recognized that they offered an almost ideal solution to tracer selection. This book is devoted to reviewing the present status of the tracer method as such and to its applications to those branches of industry which have derived large benefits from the use of this modern technology. The main objectives of the IAEA's Industrial Applications and Chemistry Section is to help Member States in introducing to their own industries the different isotope and radiation techniques which have become available as a result of developments in the nuclear sciences. This section proposed the preparation of this guidebook, putting together various radiotracer methods and the experience obtained so far in their industrial use. Chapters 2 to 4 cover the general concept of tracers, technology and safety aspects, as well as data evaluation and interpretation. In chapter 5, therefore, general applications are discussed. In chapter 6, specialists in selected fields discuss their experience in radiotracer applications in various types of industrial activity. Most case studies are illustrated by at least one detailed example of an experiment carried out at an industrial installation. Current trends in the development of radiotracer methods are discussed in chapter 7, from both a theoretical and a practical viewpoint. Some possible new RTT applications in the future are also discussed here. Sealed radioactive sources are used almost as often as radioisotope tracers in industrial measurements. Annex I gives a short review of these techniques. Readers who are interested in the basic principles of radioisotope production will find the necessary information in Annex II. Annexes III, V and VI provide a demonstration of fundamental relations and properties; useful

  3. "The relationship between pharmacokinetic variables and pharmacodynamic profiles of bolus versus continuous infusion of furosemide in critically ill patients"

    Directory of Open Access Journals (Sweden)

    "Mojtaba Mojtahedzadeh

    2005-05-01

    Full Text Available In this investigation, the pharmacokinetic variables of continuous infusion and intermittent bolus injection of furosemide and the possible relationship between its pharmacokinetic characteristics and pharmacodynamic profile among intensive care unit (ICU patients were studied. In this prospective, randomized, clinical trial, twelve patients received IV bolus of 20 mg of the drug during 3 hours period and, the drug dose was doubled, when the urine output was less than 1 ml/kg/h (group 1. The other nine patients received a continuous intravenous furosemide infusion at the rate of 0.1 mg/kg/h (group 2. The amount of furosemide in serum was measured by high performance liquid chromatography (HPLC. Results showed a positive correlation between plasma clearance of furosemide and its diuretic activity (P=0.01. The pharmacokinetic parameters such as Vd (l, CL (ml/min, Ke (min-1 and t½ (min in continuous infusion patients were not significantly differed from the bolus patients (P-values 0.5, 0.9, 0.9,0.9, respectively. Nevertheless the observed plasma clearance of drug in the continuous infusion group was clinically higher than bolus injection group and as a result the cumulative urine output per hour per mg of furosemide in a continuous infusion was observed to be higher than bolus(P=0.2. Changes in serum sodium and potassium were similar for both groups, but bolus injection patients were associated with higher potassium depletion (P=0.001. Therefore, continuous infusion seems to be better means of diuretic therapy in critically ill patients.

  4. Optimization of a beam shaping bolus for superficial microwave hyperthermia waveguide applicators using a finite element method

    International Nuclear Information System (INIS)

    Kumaradas, J Carl; Sherar, Michael D

    2003-01-01

    Temperature inhomogeneity in hyperthermia treatments often limits the total thermal dose that can be delivered to the tumour region. To reduce such inhomogeneities, a prototype dynamically modifiable square array of saline-filled patches which attenuate microwave energy was developed for superficial treatments that use external microwave applicators. The array was situated inside the coupling water bolus that is often used with external applicators. The prototype has been previously tested clinically with promising results. A more complete theoretical analysis of the performance of this new bolus design and improvements to its design by modelling are presented here. The analysis was performed by performing five iterative simulations of the SAR pattern produced inside a tissue structure by a waveguide applicator with a water bolus containing the dynamic patch array attached. Between iterations the patch array configuration was modified in an attempt to improve the ability of the bolus to confine heating to an 'L'-shaped tumour region. These simulations were performed using the finite element method. The steady-state temperature profile was then computed using a finite element method based simulation of heat transfer that assumed a given applicator power level and water bolus temperature. Several iterations of these heat transfer simulations were performed with varying applicator power level and water bolus temperature to improve the confinement of heating to the target region. The analysis showed that the dynamic patch array should be capable of conforming heating to an 'L'-shaped target tumour region while limiting the heating to the surrounding normal tissue to an acceptable level

  5. The velocity of a radioactive bolus in the oesophagus evaluated by means of an image segmentation algorithm

    International Nuclear Information System (INIS)

    Miquelin, Charlie A; Dantas, Roberto O; Oliveira, Ricardo B; Braga, Francisco Jos H. N

    2002-01-01

    Classical scintigraphic evaluation of a radioactive bolus through the oesophagus is based on regions of interest and time/activity curves, which only gives information about the total time required for it to cross the organ. Instantaneous parameters can be obtained if the exact position (centroid) of the bolus is known. For that, one needs to know the co-ordinates of the centre of mass of the bolus radioactivity distribution. From this, one can obtain velocity at each time. Obtaining such a new parameter would be important, to try to determine whether the anatomical differences among the 3 thirds of the oesophagus have a functional correspondence or not. We have studied 5 normal volunteers (4 males, 1 female, 33-68 yo). Each volunteer swallowed (unique swallowing) 40 MBq of 99mTc-phytate in 10 ml water. Eighty frames (0.3 sec) were acquired in a scintillation camera. External marks were used to separate the pharynx from the oesophagus. Images were transformed into bitmap by means of a Sophy Medical processing module and analysed by means of the algorithm, which determines the co-ordinates of the centroid (horizontal and vertical) for each frame and instant velocities through the organ. Different velocities were found in typical evaluations. Curves representing the different positions of the bolus C and the correspondent different Vs were obtained. Different velocities of the bolus were detected during the pharyngeal phase, and proximal, mid and distal parts of the oesophagus. Larger studies are necessary, but it seems that the velocity of a radioactive bolus changes in the different parts of the oesophagus. It is reasonable to say that there is a functional correspondence to the anatomical differences in the organ (Au)

  6. Rapid Bolus Administration Does not Increase The Extravasation Rate of Albumin: A Randomized Controlled Trial in The Endotoxemic Pig.

    Science.gov (United States)

    von Seth, Magnus; Lipcsey, Miklós; Engström, Peter; Larsson, Anders; Hillered, Lars; Maripuu, Enn; Widström, Charles; Sjölin, Jan

    2017-04-01

    Some experimental data suggest that rapid bolus administration of albumin causes less plasma-expanding effects than slow, continuous infusion. To determine whether rapid bolus administration, in comparison with slow infusion, results in greater extravasation of albumin in experimental septic shock we performed a randomized controlled trial with 32 endotoxemic pigs. The animals were monitored and ventilated with standard intensive care equipment and given 10 mL × kg 5% albumin labeled with Technetium-99m, either as a rapid 15-min bolus (Bolus group, n = 16) or as a 2-h infusion (Infusion group, n = 16). Radioactivity was monitored in plasma, extracellular microdialysate, and urine for 6 h. Physiological parameters were monitored hourly. Radioactivity in the liver, spleen, kidney, and lung was analyzed post mortem.The plasma area under the curve activity0-6 h was 4.4 ± 0.9 × 10 in the Bolus group and 4.4 ± 1.1 × 10 counts × min × mL × h in the Infusion group. Blood hemoglobin levels increased in both groups, suggesting severe capillary leakage. Yet, there were no group differences in albumin radioactivity in plasma, muscle tissue, urine, or in the post-mortem analysis of the organs. Following albumin administration, circulatory and respiratory parameters were similar in the two groups.In conclusion, the present results suggest that albumin might be given as a bolus without leading to increased extravasation of albumin, in contrast to previous animal experiments in rodents.

  7. The application of DSA bolus chase technology in diagnosing the vascular disorders of lower extremities due to diabetes mellitus

    International Nuclear Information System (INIS)

    Ren Chongyang; Di Zhenhai; Mao Xuequn; Zou Rong; Zhang Jian; Wang Meirong; Li Quan

    2010-01-01

    Objective: To retrospectively evaluate the digital subtraction angiography (DSA) bolus chase technology in diagnosing the vascular disorders of lower extremities due to diabetes mellitus. Methods: From January 2004 to March 2010, DSA was performed in forty-five diabetes patients with suspicious vascular diseases of lower extremities. Among them, 24 cases (31 lower limbs)were examined with DSA bolus chase technology and the remaining 21 cases (21 lower limbs)were examined with traditional segmentational technique. The contrast dosage used in angiography, the total exposure time, the examination time and the imaging value for making diagnosis were analyzed and compared between two techniques. Results: For DSA bolus chase technology group, the contrast dosage used in angiography, the total exposure time and the examination time were 25.26 ml, 13.23 s and 37.26 min, respectively,with an average exposure of 101.65 pictures. For traditional segmentational technique group, the contrast dosage used in angiography, the total exposure time and the examination time were 130.00 ml, 52.38 s and 50.48 min, respectively, with an average exposure of 118.33 pictures. The percentage of high quality images in bolus chase technology group and in traditional segmentational technique group were 90.3% and 90.5%, respectively. All the images could meet the requirements for making a reliable diagnosis. Conclusion: Digital subtraction angiography by using bolus-chase technology can well demonstrate the vascular pathology of lower extremities caused by diabetes mellitus, obtain sufficient imaging information necessary for making a reliable diagnosis. DSA bolus chase technology is superior to traditional segmentational technique in shortening procedure time, reducing contrast medium dosage and decreasing radiation dose. (authors)

  8. Bolus and continuous infusion mitoxantrone in newly diagnosed adult acute lymphoblastic leukemia: results of two consecutive phase II clinical studies.

    Science.gov (United States)

    Koc, Y; Akpek, G; Kansu, E; Kars, A; Tekuzman, G; Baltali, E; Güler, N; Barista, I; Güllü, I; Ozisik, Y; Firat, D

    1998-01-01

    Two consecutive phase II clinical studies were designed to evaluate the efficacy and safety of bolus and continuous infusion (CI) mitoxantrone (MTZ) in 39 patients with newly diagnosed acute lymphocytic leukemia (ALL). MTZ was used as part of the classical ALL induction regimen. Twenty patients were treated with bolus MTZ (10 mg/m2 for 3 days) combined with vincristine and prednisone. The same regimen was given to a second set of 19 patients, except that MTZ was administered as a 24-hr CI. Both groups received bimonthly intensifications with vincristine and prednisone for 3 years, along with oral maintenance therapy. Patients in the CI-MTZ study arm received additional MTZ on the first day of intensification cycles. Seventeen patients (85%) in the bolus arm and 15 patients (79%) in the CI arm achieved complete remission (CR). Median disease-free survivals (DFS) in the bolus and CI groups were 11 and 15 months after median follow-ups of 16 (3.5-96) and 13 (2.3-32) months, respectively. At 2.5 years, DFS rates were 29.4% and 34.4% in the bolus and CI groups (p > 0.05). There were no significant differences between two groups in rates of early death, degree of organ toxicity, or duration of neutropenia and thrombocytopenia. Significant cardiac toxicity was not observed in either group. Bolus or CI administration of MTZ was equally effective and was well tolerated. Neither the mode of administration nor increasing the dose intensity of MTZ by incorporating intensification cycles reduced relapse rates. Development of new antileukemia agents and novel treatment approaches are still needed to improve the high relapse rates in adult ALL once a complete response is achieved.

  9. Onset and effectiveness of rocuronium for rapid onset of paralysis in patients with major burns: priming or large bolus

    Science.gov (United States)

    Han, T.-H.; Martyn, J. A. J.

    2009-01-01

    Background Burn injury leads to resistance to the effects of non-depolarizing muscle relaxants. We tested the hypothesis that a larger bolus dose is as effective as priming for rapid onset of paralysis after burns. Methods Ninety adults, aged 18–59 yr with 40 (2)% [mean (se)] burn and 30 (2) days after injury, received rocuronium as a priming dose followed by bolus (0.06+0.94 mg kg−1), or single bolus of either 1.0 or 1.5 mg kg−1. Sixty-one non-burned, receiving 1.0 mg kg−1 as a primed (0.06+0.94 mg kg−1) or full bolus dose, served as controls. Acceleromyography measured the onset times. Results Priming when compared with 1.0 mg kg−1 bolus in burned patients shortened the time to first appearance of twitch depression (30 vs 45 s, P<0.05) and time to maximum twitch inhibition (135 vs 210 s, P<0.05). The onset times between priming and higher bolus dose (1.5 mg kg−1) were not different (30 vs 30 s for first twitch depression and 135 vs 135 s for maximal depression, respectively). The onset times in controls, however, were significantly (P<0.05) faster than burns both for priming and for full bolus (15 and 15 s, respectively, for first twitch depression and 75 and 75 s for maximal depression). Priming caused respiratory distress in 10% of patients in both groups. Intubating conditions in burns were significantly better with 1.5 mg kg−1 than with priming or full 1.0 mg kg−1 bolus. Conclusions A dose of 1.5 mg kg−1 not only produces an initial onset of paralysis as early as 30 s, which we speculate could be a reasonable onset time for relief of laryngospasm, but also has an onset as fast as priming with superior intubating conditions and no respiratory side-effects. PMID:19029093

  10. New radioactive tracers can help find cause of jaundice

    International Nuclear Information System (INIS)

    Carrard, G.

    1987-01-01

    Radioactive tracers for the investigation of a condition known as persistent jaundice of the newborn, have been designed, prepared and tested at ANSTO. The tracers are chemical compounds of the radioactive elements gallium-67 and indium-111. They given lower radiation doses than the conventional radioactive tracer, iodine-131, used in these studies

  11. PET tracers for somatostatin receptor imaging of neuroendocrine tumors

    DEFF Research Database (Denmark)

    Johnbeck, Camilla Bardram; Knigge, Ulrich; Kjær, Andreas

    2014-01-01

    Neuroendocrine tumors have shown rising incidence mainly due to higher clinical awareness and better diagnostic tools over the last 30 years. Functional imaging of neuroendocrine tumors with PET tracers is an evolving field that is continuously refining the affinity of new tracers in the search...... these PET tracers further....

  12. Industrial tracer application in people's republic of china

    International Nuclear Information System (INIS)

    Sun Maoyi

    1987-01-01

    A number of important applications of radioisotopes and their compounds used as tracers in petroleum industry, metallurgical industry, mechanical industry, chemical industry, electronic industry, hydrology and water conservancy in China are introduced in this paper. And the tracer technique applied to entomology is also mentioned. The industrial tracer applications are successful and beneficial in People's Republic of China from the examples given. (author)

  13. Natural tracer profiles across argillaceous formations

    International Nuclear Information System (INIS)

    Mazurek, Martin; Alt-Epping, Peter; Bath, Adrian; Gimmi, Thomas; Niklaus Waber, H.; Buschaert, Stephane; Canniere, Pierre De; Craen, Mieke De; Gautschi, Andreas; Savoye, Sebastien; Vinsot, Agnes; Wemaere, Isabelle; Wouters, Laurent

    2011-01-01

    Highlights: → Solute transport processes in clay and shale formations at nine sites are examined. → Conservative pore-water tracers (e.g. Cl - , δ 18 O, δ 2 H, He) show regular profiles. → These indicate the dominance of diffusive transport over times of 10 5 -10 6 years. → The contribution of vertical advection to transport is limited or negligible. → Modelled evolution times are in line with independent palaeo-hydrogeological data. - Abstract: Argillaceous formations generally act as aquitards because of their low hydraulic conductivities. This property, together with the large retention capacity of clays for cationic contaminants, has brought argillaceous formations into focus as potential host rocks for the geological disposal of radioactive and other waste. In several countries, programmes are under way to characterise the detailed transport properties of such formations at depth. In this context, the interpretation of profiles of natural tracers in pore waters across the formations can give valuable information about the large-scale and long-term transport behaviour of these formations. Here, tracer-profile data, obtained by various methods of pore-water extraction for nine sites in central Europe, are compiled. Data at each site comprise some or all of the conservative tracers: anions (Cl - , Br - ), water isotopes (δ 18 O, δ 2 H) and noble gases (mainly He). Based on a careful evaluation of the palaeo-hydrogeological evolution at each site, model scenarios are derived for initial and boundary pore-water compositions and an attempt is made to numerically reproduce the observed tracer distributions in a consistent way for all tracers and sites, using transport parameters derived from laboratory or in situ tests. The comprehensive results from this project have been reported in . Here the results for three sites are presented in detail, but the conclusions are based on model interpretations of the entire data set. In essentially all cases, the

  14. Triphasic contrast enhanced CT simulation with bolus tracking for pancreas SBRT target delineation.

    Science.gov (United States)

    Godfrey, Devon J; Patel, Bhavik N; Adamson, Justus D; Subashi, Ergys; Salama, Joseph K; Palta, Manisha

    Bolus-tracked multiphasic contrast computed tomography (CT) is often used in diagnostic radiology to enhance the visibility of pancreas tumors, but is uncommon in radiation therapy pancreas CT simulation, and its impact on gross tumor volume (GTV) delineation is unknown. This study evaluates the lesion conspicuity and consistency of pancreas stereotactic body radiation therapy (SBRT) GTVs contoured in the different contrast phases of triphasic CT simulation scans. Triphasic, bolus-tracked planning CT simulation scans of 10 consecutive pancreas SBRT patients were acquired, yielding images of the pancreas during the late arterial (LA), portal venous (PV), and either the early arterial or delayed phase. GTVs were contoured on each phase by a gastrointestinal-specialized radiation oncologist and reviewed by a fellowship-trained abdominal radiologist who specializes in pancreatic imaging. The volumes of the registered GTVs, their overlap ratio, and the 3-dimensional margin expansions necessary for each GTV to fully encompass GTVs from the other phases were calculated. The contrast difference between tumor and normal pancreas was measured, and 2 radiation oncologists rank-ordered the phases according to their value for the lesion-contouring task. Tumor-to-pancreas enhancement was on average much larger for the LA and PV than the delayed phase or early arterial phases; the LA and PV phases were also consistently preferred by the radiation oncologists. Enhancement differences among the phases resulted in highly variable GTV volumes with no observed trends. Overlap ratios ranged from 18% to 75% across all 3 phases, improving to 43% to 91% when considering only the preferred LA and PV phases. GTV expansions necessary to encompass all GTVs ranged from 0.3 to 1.8 cm for all 3 phases, improving slightly to 0.1 to 1.4 cm when considering just the LA and PV phases. For pancreas SBRT, we recommend combining the GTVs from a multiphasic CT simulation with bolus-tracking, including

  15. Anchoring effect on first passage process in Taiwan financial market

    Science.gov (United States)

    Liu, Hsing; Liao, Chi-Yo; Ko, Jing-Yuan; Lih, Jiann-Shing

    2017-07-01

    Empirical analysis of the price fluctuations of financial markets has received extensive attention because a substantial amount of financial market data has been collected and because of advances in data-mining techniques. Price fluctuation trends can help investors to make informed trading decisions, but such decisions may also be affected by a psychological factors-the anchoring effect. This study explores the intraday price time series of Taiwan futures, and applies diffusion model and quantitative methods to analyze the relationship between the anchoring effect and price fluctuations during first passage process. Our results indicate that power-law scaling and anomalous diffusion for stock price fluctuations are related to the anchoring effect. Moreover, microscopic price fluctuations before switching point in first passage process correspond with long-term price fluctuations of Taiwan's stock market. We find that microscopic trends could provide useful information for understanding macroscopic trends in stock markets.

  16. Simple relations between mean passage times and Kramers' stationary rate

    International Nuclear Information System (INIS)

    Boilley, David; Jurado, Beatriz; Schmitt, Christelle

    2004-01-01

    The classical problem of the escape time of a metastable potential well in a thermal environment is generally studied by various quantities like Kramers' stationary escape rate, mean first passage time, nonlinear relaxation time, or mean last passage time. In addition, numerical simulations lead to the definition of other quantities as the long-time limit escape rate and the transient time. In this paper, we propose some simple analytical relations between all these quantities. In particular, we point out the hypothesis used to evaluate these various times in order to clarify their comparison and applicability, and show how average times include the transient time and the long-time limit of the escape rate

  17. Passages of high energy hadrons through atomic nuclei

    International Nuclear Information System (INIS)

    Strugalska-Gola, E.; Strugalski, Z.

    2001-01-01

    The subject matter in this paper are descriptions of more important results of investigations of the intranuclear matter properties by means of hadronic probes (pionic, e.g.). The projectile-nucleus collisions occurred in liquid xenon in the 180 litre xenon bubble chamber. The chamber in the experiments was practically a total 4π angle aperture for detection of the secondary products from the hadron-nucleus collision reactions. All the π +-0 mesons were practically registered with an efficiency near to 100 %. The hadron passages through nuclei (through layers of intranuclear matter) in their pure sort, when multiparticle creation does not occur, were observed. Conclusive information, obtained on the hadron passages, is presented here. It may be used for new nuclear power technology, in radioactive waste neutralization, in other works on intranuclear matter properties

  18. Effect of stress on turbine fish passage mortality estimates

    International Nuclear Information System (INIS)

    Ruggles, C.P.

    1993-01-01

    Tests were conducted with juvenile alewife to determine the effects of four experimental protocols upon turbine fish passage mortality estimates. Three protocols determined the effect of cumulative stresses upon fish, while the fourth determined the effect of long range truck transportation prior to release into the penstock or tailrace. The wide range in results were attributed to the presence or absence of additional stress factors associated with the experiments. For instance, fish may survive passage through a turbine, or non-turbine related stresses imposed by the investigator; however, when both are imposed, the cumulative stresses may be lethal. The impact of protocol stress on turbine mortality estimates becomes almost exponential after control mortality exceeds 10%. Valid turbine related mortalities may be determined only after stresses associated with experimental protocol are adequately reduced. This is usually indicated by a control mortality of less than 10%. 14 refs., 5 figs., 6 tabs

  19. Entropy Minimization Design Approach of Supersonic Internal Passages

    Directory of Open Access Journals (Sweden)

    Jorge Sousa

    2015-08-01

    Full Text Available Fluid machinery operating in the supersonic regime unveil avenues towards more compact technology. However, internal supersonic flows are associated with high aerodynamic and thermal penalties, which usually prevent their practical implementation. Indeed, both shock losses and the limited operational range represent particular challenges to aerodynamic designers that should be taken into account at the initial phase of the design process. This paper presents a design methodology for supersonic passages based on direct evaluations of the velocity field using the method of characteristics and computation of entropy generation across shock waves. This meshless function evaluation tool is then coupled to an optimization scheme, based on evolutionary algorithms that minimize the entropy generation across the supersonic passage. Finally, we assessed the results with 3D Reynolds Averaged Navier Stokes calculations.

  20. The reliability and validity of passive leg raise and fluid bolus to assess fluid responsiveness in spontaneously breathing emergency department patients

    DEFF Research Database (Denmark)

    Duus, Nicolaj; Shogilev, Daniel J; Skibsted, Simon

    2015-01-01

    PURPOSE: We investigated the reproducibility of passive leg raise (PLR) and fluid bolus (BOLUS) using the Non-Invasive Cardiac Output Monitor (NICOM; Cheetah Medical, Tel Aviv, Israel) for assessment of fluid responsiveness (FR) in spontaneously breathing emergency department (ED) patients. METHODS...

  1. First-passage exponents of multiple random walks

    International Nuclear Information System (INIS)

    Ben-Naim, E; Krapivsky, P L

    2010-01-01

    We investigate first-passage statistics of an ensemble of N noninteracting random walks on a line. Starting from a configuration in which all particles are located in the positive half-line, we study S n (t), the probability that the nth rightmost particle remains in the positive half-line up to time t. This quantity decays algebraically, S n (t)∼t -β n , in the long-time limit. Interestingly, there is a family of nontrivial first-passage exponents, β 1 2 N-1 ; the only exception is the two-particle case where β 1 = 1/3. In the N → ∞ limit, however, the exponents attain a scaling form, β n (N) → β(z) with z=(n-N/2)/√N. We also demonstrate that the smallest exponent decays exponentially with N. We deduce these results from first-passage kinetics of a random walk in an N-dimensional cone and confirm them using numerical simulations. Additionally, we investigate the family of exponents that characterizes leadership statistics of multiple random walks and find that in this case, the cone provides an excellent approximation.

  2. Benefits of fish passage and protection measures at hydroelectric projects

    International Nuclear Information System (INIS)

    Cada, G.F.; Jones, D.W.

    1993-01-01

    The US Department of Energy's Hydropower Program is engaged in a multi-year study of the costs and benefits of environmental mitigation measures at nonfederal hydroelectric power plants. An initial report (Volume 1) reviewed and surveyed the status of mitigation methods for fish passage, instream flows, and water quality; this paper focuses on the fish passage/protection aspects of the study. Fish ladders were found to be the most common means of passing fish upstream; elevators/lifts were less common, but their use appears to be increasing. A variety of mitigative measures is employed to prevent fish from being drawn into turbine intakes, including spill flows, narrow-mesh intake screens, angled bar racks, and lightor sound-based guidance measures. Performance monitoring and detailed, quantifiable performance criteria were frequently lacking at non-federal hydroelectric projects. Volume 2 considers the benefits and costs of fish passage and protection measures, as illustrated by case studies for which performance monitoring has been conducted. The report estimates the effectiveness of particular measures, the consequent impacts on the fish populations that are being maintained or restored, and the resulting use and non-use values of the maintained or restored fish populations

  3. Effects of hydroelectric turbine passage on fish early life stages

    International Nuclear Information System (INIS)

    Cada, G.F.

    1991-01-01

    Turbine-passage mortality has been studied extensively for juveniles and adults of migratory fish species, but few studies have directly quantified orality of fish eggs and larvae. This paper provides an analysis of literature relating to component stresses of turbine passage (i.e., pressure changes, blade contact, and shear) which indicates that mortality of early life stages of fish would be relatively low at low-head, bulb turbine installations. The shear forces and pressure regimes normally experienced are insufficient to cause high mortality rates. The probability of contact with turbine blades is related to the size of the fish; less than 5% of entrained ichthyoplankton would be killed by the blades in a bulb turbine. Other sources of mortality (e.g., cavitation and entrainment of fish acclimated to deep water) are controlled by operation of the facility and thus are mitigable. Because turbine-passage mortality among fish early life stages can be very difficult to estimate directly, it may be more fruitful to base the need for mitigation at any given site on detailed knowledge of turbine characteristics and the susceptibility of the fish community to entrainment

  4. Is motivation important to brook trout passage through culverts?

    Science.gov (United States)

    Goerig, Elsa; Castro-Santos, Theodore R.

    2017-01-01

    Culverts can restrict movement of stream-dwelling fish. Motivation to enter and ascend these structures is an essential precursor for successful passage. However, motivation is challenging to quantify. Here, we use attempt rate to assess motivation of 447 brook trout (Salvelinus fontinalis) entering three culverts under a range of hydraulic, environmental, and biological conditions. A passive integrated transponder system allowed for the identification of passage attempts and success of individual fish. Attempt rate was quantified using time-to-event analysis allowing for time-varying covariates and recurrent events. Attempt rate was greatest during the spawning period, at elevated discharge, at dusk, and for longer fish. It decreased during the day and with increasing number of conspecifics downstream of the culvert. Results also show a positive correlation between elevated motivation and successful passage. This study enhances understanding of factors influencing brook trout motivation to ascend culverts and shows that attempt rate is a dynamic phenomenon, variable over time and among individuals. It also presents methods that could be used to investigate other species’ motivation to pass natural or anthropogenic barriers.

  5. The use of tracers in the study of the ionic permeability of the nerve

    International Nuclear Information System (INIS)

    Guinnebault, M.

    1961-01-01

    The use of the radioactive tracers 24 Na and 42 K, and the electrophysiological fine study carried out on the plant Cephalopods nervous cells have made it possible, during ten years, to study the relationships between the electrical phenomena observed during the propagation of the nervous impulse and the ionic movements which occur at the cell membrane between the intra- and extra-cellular media. In the state of rest, the nerve fibres present a certain permeability towards sodium and potassium, a permeability which allows the renewal, from the extra-cellular medium, of the cations contained in the cytoplasm. At the moment of the passage of the nervous impulse, it is possible to demonstrate a temporary increase in the permeability towards the sodium which causes the entry of Na + ions into the nerve fibre, whilst, a few milliseconds later, the increase in the potassium permeability causes the departure of an equivalent quantity of K + ions. A recovery phase follows the passage of the nervous impulse, during which the original ionic conditions are re-established. If the potassium movements can be considered as passive, the expulsion of Na + requires, on the part of the cell, the use of a part of the metabolic energy. (author) [fr

  6. Radiotherapy in differentiated thyroid cancer: Optimal dose distribution using a wax bolus

    International Nuclear Information System (INIS)

    Mayer, R.; Stucklschweiger, G.; Oechs, A.; Pakish, B.; Hackl, A.; Preidler, K.; Szola, D.

    1994-01-01

    The study includes 53 patients with differentiated thyroid cancer, who underwent surgical and radioiodine therapy as well as hormone therapy. Postoperative radiotherapy was performed in all patients in 'mini-mantle-technique' with parallel opposed fields, followed by an anterior boost-field with electrons up to 60-64 Gy, using a wax bolus for optimal dose distribution in the target volume sparing out the spinal cord as much as possible. The dose to the spinal cord did not exceed 44 Gy in any case. The study shows that radiotherapy with doses up to 60-64 Gy plays an important role in postsurgical therapeutic management. Therefore nonradical surgery is a less important prognostic factor for survival and local recurrence in patients with differentiated thyroid cancer than histological diagnosis in combination with age and lymph node involvement

  7. Comparison of /sup 133/Xe washout curves after bolus inhalation, perfusion, and equilibration

    Energy Technology Data Exchange (ETDEWEB)

    Devos, P; Demedts, M; Vandecruys, A; Cosemans, J; De Roo, M

    1978-01-01

    In 6 healthy subjects and 13 patients with chronic obstructive lung disease, /sup 133/Xe washout curves after bolus inhalation, perfusion and equilibration were compared, using a gamma camera and computerized data handling. In healthy subjects the washout after equilibration was significantly slower than after the two other procedures. As this phenomenon occurred at the basal zones, it was attributed to the presence of airway closure in some units. In patients, the three washouts were significantly different from each other. This indicated the existence of intraregional inhomogeneity in ventilation, perfusion and ventilation-perfusion ratio. Our conclusion is that comparison of these different washout methods yields valuable information not only on absolute values of pulmonary function but also on the intraregional distribution, which cannot be obtained by other examinations.

  8. Intratracheal Milrinone Bolus Administration During Acute Right Ventricular Dysfunction After Cardiopulmonary Bypass.

    Science.gov (United States)

    Gebhard, Caroline Eva; Desjardins, Georges; Gebhard, Cathérine; Gavra, Paul; Denault, André Y

    2017-04-01

    To evaluate intratracheal milrinone (tMil) administration for rapid treatment of right ventricular (RV) dysfunction as a novel route after cardiopulmonary bypass. Retrospective analysis. Single-center study. The study comprised 7 patients undergoing cardiac surgery who exhibited acute RV dysfunction after cardiopulmonary bypass. After difficult weaning caused by cardiopulmonary bypass-induced acute RV dysfunction, milrinone was administered as a 5-mg bolus inside the endotracheal tube. RV function improvement, as indicated by decreasing pulmonary artery pressure and changes of RV waveforms, was observed in all 7 patients. Adverse effects of tMil included dynamic RV outflow tract obstruction (2 patients) and a decrease in systemic mean arterial pressure (1 patient). tMil may be an effective, rapid, and easily applicable therapeutic alternative to inhaled milrinone for the treatment of acute RV failure during cardiac surgery. However, sufficiently powered clinical trials are needed to confirm these findings. Copyright © 2017 Elsevier Inc. All rights reserved.

  9. 15N tracer techniques in pediatric research

    International Nuclear Information System (INIS)

    Heine, W.; Richter, I.; Plath, C.; Wutzke, K.; Stolpe, H.J.; Tiess, M.; Toewe, J.

    1983-01-01

    The main topics of the review comprise mathematical fundamentals of the determination of N metabolism parameters using the 3-pool method, the value of different 15 N tracer substances for the determination of whole-body protein parameters, the utilization of parenterally applied D-amino acids, studies on the influence of different diets on the N metabolism of premature infants with the 15 N tracer technique, the application of the 15 N-glycine-STH-test for the evaluation of the therapeutic effect of STH in children suffering from hypothalamico-hypophyseal dwarfism, in vivo studies on urea utilization by the infant intestinal flora under various dietary regimens as well as in vitro investigations on the utilization of 15 N-labelled urea and NH 4 Cl, resp., by the intestinal flora

  10. Factors predicting incremental administration of antihypertensive boluses during deep brain stimulator placement for Parkinson's disease.

    Science.gov (United States)

    Rajan, Shobana; Deogaonkar, Milind; Kaw, Roop; Nada, Eman Ms; Hernandez, Adrian V; Ebrahim, Zeyd; Avitsian, Rafi

    2014-10-01

    Hypertension is common in deep brain stimulator (DBS) placement predisposing to intracranial hemorrhage. This retrospective review evaluates factors predicting incremental antihypertensive use intraoperatively. Medical records of Parkinson's disease (PD) patients undergoing DBS procedure between 2008-2011 were reviewed after Institutional Review Board approval. Anesthesia medication, preoperative levodopa dose, age, preoperative use of antihypertensive medications, diabetes mellitus, anxiety, motor part of the Unified Parkinson's Disease Rating Scale score and PD duration were collected. Univariate and multivariate analysis was done between each patient characteristic and the number of antihypertensive boluses. From the 136 patients included 60 were hypertensive, of whom 32 were on angiotensin converting enzyme inhibitors (ACEI) or angiotensin receptor blockers (ARB), told to hold on the morning of surgery. Antihypertensive medications were given to 130 patients intraoperatively. Age (relative risk [RR] 1.01; 95% confidence interval [CI] 1.00-1.02; p=0.005), high Joint National Committee (JNC) class (p10 years (RR 1.2; 95%CI 1.1-1.3; p=0.001) were independent predictors for antihypertensive use. No difference was noted in the mean dose of levodopa (p=0.1) and levodopa equivalent dose (p=0.4) between the low (I/II) and high severity (III/IV) JNC groups. Addition of dexmedetomidine to propofol did not influence antihypertensive boluses required (p=0.38). Intraoperative hypertension during DBS surgery is associated with higher age group, hypertensive, diabetic patients and longer duration of PD. Withholding ACEI or ARB is an independent predictor of hypertension requiring more aggressive therapy. Levodopa withdrawal and choice of anesthetic agent is not associated with higher intraoperative antihypertensive medications. Copyright © 2014 Elsevier Ltd. All rights reserved.

  11. Discounting the duration of bolus exposure in impedance testing underestimates acid reflux.

    Science.gov (United States)

    Vikneswaran, Namasivayam; Murray, Joseph A

    2016-06-08

    Combined impedance-pH testing (MII) allows for detection of reflux episodes regardless of pH. However impedance-based diagnosis of reflux may not routinely account for duration of the reflux episode. We hypothesize that impedance testing may be less sensitive than pH-testing in detecting acid reflux off therapy as a result of discounting duration of exposure. Baseline characteristics and reflux parameters of MII studies performed off-anti-secretory medications were analyzed. Studies on acid suppressive medication and those with recording times less than 20 h or low baseline impedance were excluded. A total of 73 consecutive MII studies were analyzed of which 31 MII studies had elevated acid exposure while 16 were abnormal by impedance criteria. MII testing off-therapy was more likely to be abnormal by pH criteria (percent time pH reflux):[42 vs 22 % (p =0.02)]. Acid exposure (percent time pH acid reflux episodes [42 vs 34 % (p acid clearance time (pH-detected) was significantly longer than median bolus clearance time (impedance-detected) in the total [98.7 s vs 12.6 s (p acid clearance time (pH-detected) and the median bolus clearance time (impedance-detected) was significantly higher in the recumbent position compared to the upright position [11. vs 5.3 (p = 0.01)]. Ambulatory impedance testing underestimates acid reflux compared to esophageal acid exposure by discounting the prolonged period of mucosal contact with each acid reflux episode, particularly in the recumbent position.

  12. Appropriateness of Bolus Antihypertensive Therapy for Elevated Blood Pressure in the Emergency Department.

    Science.gov (United States)

    Miller, Joseph B; Arter, Andrew; Wilson, Suprat S; Janke, Alexander T; Brody, Aaron; Reed, Brian P; Levy, Phillip D

    2017-08-01

    While moderate to severely elevated blood pressure (BP) is present in nearly half of all emergency department (ED) patients, the incidence of true hypertensive emergencies in ED patients is low. Administration of bolus intravenous (IV) antihypertensive treatment to lower BP in patients without a true hypertensive emergency is a wasteful practice that is discouraged by hypertension experts; however, anecdotal evidence suggests this occurs with relatively high frequency. Accordingly, we sought to assess the frequency of inappropriate IV antihypertensive treatment in ED patients with elevated BP absent a hypertensive emergency. We performed a retrospective cohort study from a single, urban, teaching hospital. Using pharmacy records, we identified patients age 18-89 who received IV antihypertensive treatment in the ED. We defined treatment as inappropriate if documented suspicion for an indicated cardiovascular condition or acute end-organ injury was lacking. Data abstraction included adverse events and 30-day readmission rates, and analysis was primarily descriptive. We included a total of 357 patients over an 18-month period. The mean age was 55; 51% were male and 93% black, and 127 (36.4%) were considered inappropriately treated. Overall, labetalol (61%) was the most commonly used medication, followed by enalaprilat (18%), hydralazine (18%), and metoprolol (3%). There were no significant differences between appropriate and inappropriate BP treatment groups in terms of clinical characteristics or adverse events. Hypotension or bradycardia occurred in three (2%) patients in the inappropriate treatment cohort and in two (1%) patients in the appropriately treated cohort. Survival to discharge and 30-day ED revisit rates were equivalent. More than one in three patients who were given IV bolus antihypertensive treatment in the ED received such therapy inappropriately by our definition, suggesting that significant resources could perhaps be saved through education of

  13. Appropriateness of Bolus Antihypertensive Therapy for Elevated Blood Pressure in the Emergency Department

    Directory of Open Access Journals (Sweden)

    Joseph B. Miller

    2017-07-01

    Full Text Available Introduction: While moderate to severely elevated blood pressure (BP is present in nearly half of all emergency department (ED patients, the incidence of true hypertensive emergencies in ED patients is low. Administration of bolus intravenous (IV antihypertensive treatment to lower BP in patients without a true hypertensive emergency is a wasteful practice that is discouraged by hypertension experts; however, anecdotal evidence suggests this occurs with relatively high frequency. Accordingly, we sought to assess the frequency of inappropriate IV antihypertensive treatment in ED patients with elevated BP absent a hypertensive emergency. Methods: We performed a retrospective cohort study from a single, urban, teaching hospital. Using pharmacy records, we identified patients age 18–89 who received IV antihypertensive treatment in the ED. We defined treatment as inappropriate if documented suspicion for an indicated cardiovascular condition or acute end-organ injury was lacking. Data abstraction included adverse events and 30-day readmission rates, and analysis was primarily descriptive. Results: We included a total of 357 patients over an 18-month period. The mean age was 55; 51% were male and 93% black, and 127 (36.4% were considered inappropriately treated. Overall, labetalol (61% was the most commonly used medication, followed by enalaprilat (18%, hydralazine (18%, and metoprolol (3%. There were no significant differences between appropriate and inappropriate BP treatment groups in terms of clinical characteristics or adverse events. Hypotension or bradycardia occurred in three (2% patients in the inappropriate treatment cohort and in two (1% patients in the appropriately treated cohort. Survival to discharge and 30-day ED revisit rates were equivalent. Conclusion: More than one in three patients who were given IV bolus antihypertensive treatment in the ED received such therapy inappropriately by our definition, suggesting that significant

  14. Radioactive tracers and the cracking modelings

    International Nuclear Information System (INIS)

    Bettens, B.

    1982-01-01

    The use of tracers (3H and 14 C) labelled in specific positions is an intensive contribution to the understanding and the revealing of the very often complex cracking modeling. The pyrolytic decay of the phenol and the cresols, of the aniline, of the phenantrene and its hydrogenated derived products were investigated and are presented as examples. The decay mechanisms give a theoretical knowledge of the thermal cracking and allow to handle the results on an industrial scale. (AF)

  15. The medical applications of radioactive tracers

    Energy Technology Data Exchange (ETDEWEB)

    Hamilton, J.G.

    1947-12-31

    This report provides a broad yet in depth overview of the use of radioactive materials as tracers in medicine and biology for the period of 1935--1947. Particular attention is paid to is of radio-sodium, radio-iodine, radio-iron, radio-phosphorus, radio-strontium, and fission products. The main thrust of this paper is human rather than animal work and focuses in work that has been published.

  16. Factors Influencing ACT After Intravenous Bolus Administration of 100 IU/kg of Unfractionated Heparin During Cardiac Catheterization in Children.

    Science.gov (United States)

    Muster, Ileana; Haas, Thorsten; Quandt, Daniel; Kretschmar, Oliver; Knirsch, Walter

    2017-10-01

    Anticoagulation using intravenous bolus administration of unfractionated heparin (UFH) aims to prevent thromboembolic complications in children undergoing cardiac catheterization (CC). Optimal UFH dosage is needed to reduce bleeding complications. We analyzed the effect of bolus UFH on activated clotting time (ACT) in children undergoing CC focusing on age-dependent, anesthesia-related, or disease-related influencing factors. This retrospective single-center study of 183 pediatric patients receiving UFH during CC analyzed ACT measured at the end of CC. After bolus administration of 100 IU UFH/kg body weight, ACT values between 105 and 488 seconds were reached. Seventy-two percent were within target level of 160 to 240 seconds. Age-dependent differences were not obtained ( P = .407). The ACT values were lower due to hemodilution (total fluid and crystalloid administration during CC, both P ACT values but occurred more frequently in children between 1 month and 1 year of age (91%). In conclusion, with a bolus of 100 IU UFH/kg, an ACT target level of 160 to 240 seconds can be achieved during CC in children in 72%, which is influenced by hemodilution and anticoagulant and antiplatelet premedication but not by age.

  17. Changes in basal rates and bolus calculator settings in insulin pumps during pregnancy in women with type 1 diabetes

    DEFF Research Database (Denmark)

    Mathiesen, Jonathan M; Secher, Anna L; Ringholm, Lene

    2014-01-01

    OBJECTIVE: To explore insulin pump settings in a cohort of pregnant women with type 1 diabetes on insulin pump therapy with a bolus calculator. METHODS: Twenty-seven women with type 1 diabetes on insulin pump therapy were included in this study. At 8, 12, 21, 27 and 33 weeks, insulin pump setting...

  18. Taste enhancement in food gels: Effect of fracture properties on oral breakdown, bolus formation and sweetness intensity

    NARCIS (Netherlands)

    Mosca, A.C.; Velde, van de F.; Bult, J.H.F.; Boekel, van M.A.J.S.; Stieger, M.A.

    2015-01-01

    This study investigates the effects of fracture strain and fracture stress on oral breakdown, bolus formation and sweetness intensity of semi-solid food gels containing sucrose heterogeneously distributed in layers. The sweetness intensity of gels was mainly affected by the total surface area of gel

  19. Relationship between esophageal contraction patterns and clearance of swallowed liquid and solid boluses in healthy controls and patients with dysphagia

    NARCIS (Netherlands)

    Bogte, A.; Bredenoord, A. J.; Oors, J.; Siersema, P. D.; Smout, A. J. P. M.

    2012-01-01

    Background Non-obstructive dysphagia patients prove to be a difficult category for clinical management. Esophageal high-resolution manometry (HRM) is a novel method, used to analyze dysphagia. However, it is not yet clear how findings on HRM relate to bolus transport through the esophagus. Methods

  20. A prospective, randomized, blinded-endpoint, controlled study – continuous epidural infusion versus programmed intermittent epidural bolus in labor analgesia

    Directory of Open Access Journals (Sweden)

    Joana Nunes

    2016-09-01

    Full Text Available Background: There is evidence that administration of a programmed intermittent epidural bolus (PIEB compared to continuous epidural infusion (CEI leads to greater analgesia efficacy and maternal satisfaction with decreased anesthetic interventions. Methods: In this study, 166 women with viable pregnancies were included. After an epidural loading dose of 10 mL with Ropivacaine 0.16% plus Sufentanil 10 μg, parturient were randomly assigned to one of three regimens: A – Ropivacaine 0.15% plus Sufentanil 0.2 μg/mL solution as continuous epidural infusion (5 mL/h, beginning immediately after the initial bolus; B – Ropivacaine 0.1% plus Sufentanil 0.2 μg/mL as programmed intermittent epidural bolus and C – Same solution as group A as programmed intermittent epidural bolus. PIEB regimens were programmed as 10 mL/h starting 60 min after the initial bolus. Rescue boluses of 5 mL of the same solution were administered, with the infusion pump. We evaluated maternal satisfaction using a verbal numeric scale from 0 to 10. We also evaluated adverse, maternal and neonatal outcomes. Results: We analyzed 130 pregnants (A = 60; B = 33; C = 37. The median verbal numeric scale for maternal satisfaction was 8.8 in group A; 8.6 in group B and 8.6 in group C (p = 0.83. We found a higher caesarean delivery rate in group A (56.7%; p = 0.02. No differences in motor block, instrumental delivery rate and neonatal outcomes were observed. Conclusions: Maintenance of epidural analgesia with programmed intermittent epidural bolus is associated with a reduced incidence of caesarean delivery with equally high maternal satisfaction and no adverse outcomes. Resumo: Justificativa: Há evidências de que a administração de um bolus epidural intermitente programado (BEIP comparada à infusão epidural contínua (IEC resulta em maior eficácia da analgesia e da satisfação materna, com redução das intervenções anestésicas. Métodos: Neste estudo, 166

  1. The Impact of Injector-Based Contrast Agent Administration on Bolus Shape and Magnetic Resonance Angiography Image Quality

    Directory of Open Access Journals (Sweden)

    Gregor Jost

    2017-04-01

    Full Text Available Objective: To compare injector-based contrast agent (CA administration with hand injection in magnetic resonance angiography (MRA. Methods: Gadobutrol was administered in 6 minipigs with 3 protocols: (a hand injection (one senior technician, (b hand injection (6 less-experienced technicians, and (c power injector administration. The arterial bolus shape was quantified by test bolus measurements. A head and neck MRA was performed for quantitative and qualitative comparison of signal enhancement. Results: A significantly shorter time to peak was observed for protocol C, whereas no significant differences between protocols were found for peak height and bolus width. However, for protocol C, these parameters showed a much lower variation. The MRA revealed a significantly higher signal-to-noise ratio for injector-based administration. A superimposed strong contrast of the jugular vein was found in 50% of the hand injections. Conclusions: Injector-based CA administration results in a more standardized bolus shape, a higher vascular contrast, and a more robust visualization of target vessels.

  2. The measurement of fringing fields in a radio-frequency hyperthermia array with emphasis on bolus size

    NARCIS (Netherlands)

    Wiersma, J.; van Dijk, J. D.; Sijbrands, J.; Schneider, C. J.

    1998-01-01

    The limited aperture size through which the em-field of the applicator is emanated and the constraining of this em-field near the bolus' edge is related to the appearance of superficial 'hot spot' phenomena in radiative hyperthermia. Regarding systems based on the concept of the annular phased array

  3. Use of 3D printers to create a patient‐specific 3D bolus for external beam therapy

    Science.gov (United States)

    Baker, Jamie; Hsia, An Ting; Xu, Zhigang

    2015-01-01

    The purpose of this paper is to demonstrate that an inexpensive 3D printer can be used to manufacture patient‐specific bolus for external beam therapy, and to show we can accurately model this printed bolus in our treatment planning system for accurate treatment delivery. Percent depth‐dose measurements and tissue maximum ratios were used to determine the characteristics of the printing materials, acrylonitrile butadiene styrene and polylactic acid, as bolus material with physical density of 1.04 and 1.2 g/cm3, and electron density of 3.38×1023electrons/cm3 and 3.80×1023 electrons/cm3, respectively. Dose plane comparisons using Gafchromic EBT2 film and the RANDO phantom were used to verify accurate treatment planning. We accurately modeled a printing material in Eclipse treatment planning system, assigning it a Hounsfield unit of 260. We were also able to verify accurate treatment planning using gamma analysis for dose plane comparisons. With gamma criteria of 5% dose difference and 2 mm DTA, we were able to have 86.5% points passing, and with gamma criteria of 5% dose difference and 3 mm DTA, we were able to have 95% points passing. We were able to create a patient‐specific bolus using an inexpensive 3D printer and model it in our treatment planning system for accurate treatment delivery. PACS numbers: 87.53.Jw, 87.53.Kn, 87.56.ng PMID:26103485

  4. Myocardial oxygen extraction fraction measured using bolus inhalation of 15O-oxygen gas and dynamic PET

    NARCIS (Netherlands)

    Lubberink, Mark; Wong, YY; Raijmakers, P. G.; Huisman, Marc C.; Schuit, Robert C.; Luurtsema, Geert; Boellaard, Ronald; Knaapen, P; Vonk-Noordegraaf, Anton; Lammertsma, Adriaan A.

    Abstract The aim of this study was to determine the accuracy of oxygen extraction fraction (OEF) measurements using a dynamic scan protocol after bolus inhalation of 15O2. The method of analysis was optimized by investigating potential reuse of myocardial blood flow (MBF), perfusable tissue

  5. Tracer technology modeling the flow of fluids

    CERN Document Server

    Levenspiel, Octave

    2012-01-01

    A vessel’s behavior as a heat exchanger, absorber, reactor, or other process unit is dependent upon how fluid flows through the vessel.  In early engineering, the designer would assume either plug flow or mixed flow of the fluid through the vessel.  However, these assumptions were oftentimes inaccurate, sometimes being off by a volume factor of 100 or more.  The result of this unreliable figure produced ineffective products in multiple reaction systems.   Written by a pioneering researcher in the field of chemical engineering, the tracer method was introduced to provide more accurate flow data.  First, the tracer method measured the actual flow of fluid through a vessel.  Second, it developed a suitable model to represent the flow in question.  Such models are used to follow the flow of fluid in chemical reactors and other process units, like in rivers and streams, or solid and porous structures.  In medicine, the tracer method is used to study the flow of chemicals—harmful  and harmless—in the...

  6. Radon diagnostics and tracer gas measurements

    International Nuclear Information System (INIS)

    Jilek, K.; Brabec, M.

    2004-01-01

    An outline is presented of the tracer gas technique, which is used for continuous measurements of air ventilation rate (generally time-varying) and for simultaneous estimation of air ventilation rate and radon entry rate, and some of its limitations are discussed. The performance of this technique in the calculation of the air ventilation rate is demonstrated on real data from routine measurements. The potential for air ventilation rate estimation based on radon measurements only is discussed. A practical application is described of the tracer gas technique to a simultaneous estimation of the air ventilation rate and radon entry rate in a real house where the effectiveness of radon remedy was tested. The following main advantages of the CO tracer gas techniques are stressed: (i) The averaging method continuous determination of the ventilation rate with good accuracy (≤ 20 %). (ii) The newly presented and verified method based on simultaneous measurements of radon concentration and CO gas concentration enables separate continuous measurements of the radon entry rate and ventilation rate. The results of comparative measurements performed with the aim to estimate the inaccuracy in determination of radon entry rate showed acceptable and good agreement up to approximately 10 %. The results of comparative measurements performed with the aim to estimate the mutual commensuration of the method to the determination of the ventilation rate confirmed the expected unreliability the two parametric non-linear regression method, which is the most frequently used method in radon diagnostic in the Czech Republic

  7. The ATLAS DDM Tracer monitoring framework

    International Nuclear Information System (INIS)

    Zang Dongsong; Garonne, Vincent; Barisits, Martin; Lassnig, Mario; Andrew Stewart, Graeme; Molfetas, Angelos; Beermann, Thomas

    2012-01-01

    The DDM Tracer monitoring framework is aimed to trace and monitor the ATLAS file operations on the Worldwide LHC Computing Grid. The volume of traces has increased significantly since the framework was put in production in 2009. Now there are about 5 million trace messages every day and peaks can be near 250Hz, with peak rates continuing to climb, which gives the current structure a big challenge. Analysis of large datasets based on on-demand queries to the relational database management system (RDBMS), i.e. Oracle, can be problematic, and have a significant effect on the database's performance. Consequently, We have investigated some new high availability technologies like messaging infrastructure, specifically ActiveMQ, and key-value stores. The advantages of key value store technology are that they are distributed and have high scalability; also their write performances are usually much better than RDBMS, all of which are very useful for the Tracer monitoring framework. Indexes and distributed counters have been also tested to improve query performance and provided almost real time results. In this paper, the design principles, architecture and main characteristics of Tracer monitoring framework will be described and examples of its usage will be presented.

  8. Novel tracer for radiation treatment planning

    International Nuclear Information System (INIS)

    Schwarzenboeck, S.; Krause, B.J.; Herrmann, K.; Gaertner, F.; Souvatzoglou, M.; Klaesner, B.

    2011-01-01

    PET and PET/CT with innovative tracers gain increasing importance in diagnosis and therapy management, and radiation treatment planning in radio-oncology besides the widely established FDG. The introduction of [ 18 F]Fluorothymidine ([ 18 F]FLT) as marker of proliferation, [ 18 F]Fluoromisonidazole ([ 18 F]FMISO) and [ 18 F]Fluoroazomycin-Arabinoside ([ 18 F]FAZA) as tracer of hypoxia, [ 18 F]Fluoroethyltyrosine ([ 18 F]FET) and [ 11 C]Methionine for brain tumour imaging, [ 68 Ga]DOTATOC for somatostatin receptor imaging, [ 18 F]FDOPA for dopamine synthesis and radioactively labeled choline derivatives for imaging phospholipid metabolism have opened novel approaches to tumour imaging. Some of these tracers have already been implemented into radio-oncology: Amino acid PET and PET/CT have the potential to optimise radiation treatment planning of brain tumours through accurate delineation of tumour tissue from normal tissue, necrosis and edema. Hypoxia represents a major therapeutic problem in radiation therapy. Hypoxia imaging is very attractive as it may allow to increase the dose in hypoxic tumours potentially allowing for a better tumour control. Advances in hybrid imaging, i.e. the introduction of MR/PET, may also have an impact in radio-oncology through synergies related to the combination of molecular signals of PET and a high soft tissue contrast of MRI as well as functional MRI capabilities. (orig.)

  9. Commercial applications of perfluorocarbon tracer (PFT) technology

    International Nuclear Information System (INIS)

    Dietz, R.N.

    1991-06-01

    Tracer technology can be successfully applied to many leak-checking and monitoring evaluations of operating systems (e.g., building HVACs), manufacturing processes and products (e.g., air conditioners), and subsurface components and systems (e.g., underground storage tanks). Perfluorocarbon tracer (PFT) technology is the most sensitive of all tracer technologies because the ambient background levels of the five (5) routinely-used PFTs are in the range of parts per 10 15 parts of air (i.e., parts per quadrillion-ppq) and this technology's instrumentation can measure down to those levels. The effectiveness of this technology is achieved both in terms of cost (very little PFT need to be used) and detectability; for example, very small leaks can be rapidly detected. The PFT compounds, which are environmentally and biologically safe to use, are commercially available as are the sampling and analysis instrumentation. This presentation concerns (1) the steps being taken to commercialize this technology, (2) new applications of processes currently under study, and (3) applications in areas of use that will be particularly beneficial to the environment. 21 refs., 2 figs., 2 tabs

  10. Implementation of a split-bolus single-pass CT protocol at a UK major trauma centre to reduce excess radiation dose in trauma pan-CT

    International Nuclear Information System (INIS)

    Leung, V.; Sastry, A.; Woo, T.D.; Jones, H.R.

    2015-01-01

    Aim: To quantify the dose reduction and ensure that the use of a split-bolus protocol provided sufficient vascular enhancement. Materials and methods: Between 1 January 2014 and 31 May 2014, both split bolus and traditional two-phase scans were performed on a single CT scanner (SOMATOM Definition AS+, Siemens Healthcare) using a two-pump injector (Medrad Stellant). Both protocols used Siemens' proprietary tube current and tube voltage modulation techniques (CARE dose and CARE kV). The protocols were compared retrospectively to assess the dose–length product (DLP), aortic radiodensity at the level of the coeliac axis and radiodensity of the portal vein. Results: There were 151 trauma CT examinations during this period. Seventy-eight used the split-bolus protocol. Seventy-one had traditional two-phase imaging. One patient was excluded as they were under the age of 18 years. The radiodensity measurements for the portal vein were significantly higher (p<0.001) in the split-bolus protocol. The mean aortic enhancement in both protocols exceeded 250 HU, although the traditional two-phase protocol gave greater arterial enhancement (p<0.001) than the split-bolus protocol. The split-bolus protocol had a significantly lower (p<0.001) DLP with 43.5% reduction in the mean DLP compared to the traditional protocol. Conclusion: Split-bolus CT imaging offers significant dose reduction for this relatively young population while retaining both arterial and venous enhancement. -- Highlights: •We implemented a split bolus pan-CT protocol for trauma CT. •We compared the radiation dose and vascular enhancement of the split bolus protocol to a traditional two phase protocol. •The split bolus protocol had a 43.5% reduction in mean DLP

  11. Care-bolus tracking systems in multislice-helical computed tomography - a new method in the screening of cardiovascular failure?

    International Nuclear Information System (INIS)

    Stueckle, C.A.; Kickuth, R.; Kirchner, E.M.; Liermann, D.; Kirchner, J.

    2002-01-01

    Purpose. Recently bolus tracking systems were developed to improve the timing of intravenous contrast media application in helical computed tomography. We investigated the benefit of this new method as a parameter of the cardiac function.Material and methods. Retrospective analysis of 64 patients which incidentally underwent bolus triggered contrast enhanced helical CT and invasive investigation of the heart within one week. All examinations were performed on the CT scanner Somatom Plus 4 Volume Zoom (Siemens Corp., Forchheim, Germany) using the C.A.R.E. trademark Bolus software. This performs repetitive low- dose test scans (e.g. for the abdomen: 140 kV, 20 mA, TI 0,5 s) and measures the Hounsfield attenuation (increase over the baseline) in a preselected region of interest. The displayed increase of vascular density over the time after peripheral contrast media injection (75 ml Iopromid (300 mg/ml), 2 ml/s) was categorised to three types: (a) rapid increase, (b) deceleration before a 100 HE threshold was reached and (c) one or more peaks. The findings of the invasive investigation of the heart were correlated to the findings of the bolus-tracking measurements.Results. The examinations were categorized as follows: 19 type A, 34 type B, 11 type C. We found a high significant correlation between the type of the Hounsfield attenuation and systolic pressure in the left ventricle. There was no correlation between the type of the Hounsfield attenuation and the diastolic pressure in the left ventricle, the pressures related to the right ventricle or the ejection fraction. The bolus- tacking system showed a sensitivity of 53, a specificity of 82, an accuracy of 70%, a positive predictive value of 70% and a negative predictive value of 70% in detection of left heart failure.Conclusion. The bolus tracking system C.A.R.E.-bolus copyright often shows atypical Hounsfield attenuation in cases of cardiac failure but is not suitable as a screening method of the cardiopulmonary

  12. 77 FR 28253 - Safety Zone; America's Cup World Series, East Passage, Narragansett Bay, RI

    Science.gov (United States)

    2012-05-14

    ...-AA00 Safety Zone; America's Cup World Series, East Passage, Narragansett Bay, RI AGENCY: Coast Guard... navigable waters of the East Passage, Narragansett Bay, Rhode Island, during the America's Cup World Series... rulemaking (NPRM) entitled ``Safety Zones; America's Cup World Series, East Passage, Narragansett Bay, RI...

  13. Compartmental Modeling and Dosimetry of in Vivo Metabolic Studies of Leucine and Three Secretory Proteins in Humans Using Radioactive Tracers

    Science.gov (United States)

    Venkatakrishnan, Vaidehi

    1995-01-01

    Physical and mathematical models provide a systematic means of looking at biological systems. Radioactive tracer kinetic studies open a unique window to study complex tracee systems such as protein metabolism in humans. This research deals with compartmental modeling of tracer kinetic data on leucine and apolipoprotein metabolism obtained using an endogenous tritiated leucine tracer administered as a bolus, and application of compartmental modeling techniques for dosimetric evaluation of metabolic studies of radioiodinated apolipoproteins. Dr. Waldo R. Fisher, Department of Medicine, was the coordinating research supervisor and the work was carried out in his laboratory. A compartmental model for leucine kinetics in humans has been developed that emphasizes its recycling pathways which were examined over two weeks. This model builds on a previously published model of Cobelli et al, that analyzed leucine kinetic data up to only eight hours. The proposed model includes different routes for re-entry of leucine from protein breakdown into plasma accounting for proteins which turn over at different rates. This new model successfully incorporates published models of three secretory proteins: albumin, apoA-I, and VLDL apoB, in toto thus increasing its validity and utility. The published model of apoA-I, based on an exogenous radioiodinated tracer, was examined with data obtained using an endogenous leucine tracer using compartmental techniques. The analysis concludes that the major portion of apoA-I enters plasma by a fast pathway but the major fraction of apoA-I in plasma resides with a second slow pathway; further the study is suggestive of a precursor-product relationship between the two plasma apoA-I pools. The possible relevance of the latter suggestion to the aberrant kinetics of apoA-I in Tangier disease is discussed. The analysis of apoA-II data resulted in similar conclusions. A methodology for evaluating the dosimetry of radioiodinated apolipoproteins by

  14. Poster - 38: On the physical and dosimetric properties of 3D printed electron bolus fabricated using polylactic acid

    Energy Technology Data Exchange (ETDEWEB)

    Sasaki, David; Jensen, Martin; Rickey, Daniel W; Dubey, Arbind; Harris, Chad; McCurdy, Boyd [CancerCare Manitoba, CancerCare Manitoba, CancerCare Manitoba, CancerCare Manitoba, CancerCare Manitoba, CancerCare Manitoba (Canada)

    2016-08-15

    Purpose: 3D printing technology could simplify and improve electron bolus fabrication. The purpose of this study was to characterize the density, dimensional accuracy, uniformity, and attenuation of PLA boluses fabricated with a low-cost 3D printer. Methods: Several solid square slabs were printed with specific requested dimensions and 100% infill using different fill patterns. These pieces were imaged using an x-ray flat panel imager in order to check for uniformity of the prints. Percentage depth doses (PDDs) were measured downstream of the slabs in solid water using a parallel plate chamber and compared to measurements in water in order to characterize attenuation. The dimensions of the PLA slabs were measured using digital calipers. The slabs were also weighed to find their density. Results: The fill pattern used to create boluses can affect the attenuation of the bolus. Fill patterns should be chosen carefully and quality assurance should be done for each printed piece. PLA causes the electron PDD to shift towards shallower depths, compared to water, by 1.7 mm for each centimeter of PLA. Agreement with design dimensions was within 1 mm in the plane of the printer bed, and within 1/3 of a millimeter (roughly the thickness of a single layer), perpendicular to the printer bed. Average density was in the range 1.20 – 1.22. Conclusions: 3D printing shows great promise for use in fabricating electron bolus. This work indicates that printed PLA can be a suitable material provided the increased attenuation is properly accounted for.

  15. SU-F-T-86: Electron Dosimetric Effects of Bolus and Lens Shielding in Treating Superficial Eye Lesions

    Energy Technology Data Exchange (ETDEWEB)

    Young, L [University of Washington Medical Center, Seattle, WA (United States); Wootton, L [University of Washington School of Medicine, Seattle, WA (United States); Gopan, O; Liao, J [University of Washington, Seattle, WA (United States)

    2016-06-15

    Purpose: Electron therapy for the treatment of ocular lymphomas requires the lens to be shielded to prevent secondary cataracts. This work evaluates the dosimetry under a suspended eyeshield with and without bolus for low energy electron fields. Methods: Film (GafChromic EBT3) dosimetry and relative output factors were measured for 6, 8, and 10 MeV electron energies. A customized 5 cm diameter circle electron orbital cutout was constructed for a 6×6 cm applicator with a lens shield, 1 cm diameter Cerrobend cylinder with 2.2 cm length, suspended from an XV film covering the open field. Relative output factors were measured using a Scanditronix electron diode in a solid water phantom. Depth dose profiles were collected for bolus thicknesses of 0, 3, and 5 mm in solid water at a source to surface distance (SSD) of 100 cm. These measurements were repeated in a Rando phantom. Results: At 5 mm, the approximate distance of the lens from the surface of the cornea, the estimated dose in solid water under the suspended lens shield was reduced to 16%, 14%, and 13% of the unblocked dose at the same depth, for electron energies of 6, 8, and 10 MeV, respectively. Applying bolus increased estimated doses under the block to 22% for 3-mm and 32% for 5-mm thicknesses for a 6 MeV incident electron beam. This effect is reduced for higher energies where the corresponding values were 15.5% and 18% for 3-mm and 5-mm for an 8 MeV electron beam. Conclusion: The application of bolus to treat superficial eye lesions of the conjunctiva increases lens dose at a depth of 5-mm under the shielding block with decreasing electron energy. Careful selection of electron energy is needed to account for electron scatter under the lens shield with the application of bolus in order to prevent cataracts.

  16. Poster - 38: On the physical and dosimetric properties of 3D printed electron bolus fabricated using polylactic acid

    International Nuclear Information System (INIS)

    Sasaki, David; Jensen, Martin; Rickey, Daniel W; Dubey, Arbind; Harris, Chad; McCurdy, Boyd

    2016-01-01

    Purpose: 3D printing technology could simplify and improve electron bolus fabrication. The purpose of this study was to characterize the density, dimensional accuracy, uniformity, and attenuation of PLA boluses fabricated with a low-cost 3D printer. Methods: Several solid square slabs were printed with specific requested dimensions and 100% infill using different fill patterns. These pieces were imaged using an x-ray flat panel imager in order to check for uniformity of the prints. Percentage depth doses (PDDs) were measured downstream of the slabs in solid water using a parallel plate chamber and compared to measurements in water in order to characterize attenuation. The dimensions of the PLA slabs were measured using digital calipers. The slabs were also weighed to find their density. Results: The fill pattern used to create boluses can affect the attenuation of the bolus. Fill patterns should be chosen carefully and quality assurance should be done for each printed piece. PLA causes the electron PDD to shift towards shallower depths, compared to water, by 1.7 mm for each centimeter of PLA. Agreement with design dimensions was within 1 mm in the plane of the printer bed, and within 1/3 of a millimeter (roughly the thickness of a single layer), perpendicular to the printer bed. Average density was in the range 1.20 – 1.22. Conclusions: 3D printing shows great promise for use in fabricating electron bolus. This work indicates that printed PLA can be a suitable material provided the increased attenuation is properly accounted for.

  17. Emission quantification using the tracer gas dispersion method: The influence of instrument, tracer gas species and source simulation

    DEFF Research Database (Denmark)

    Delre, Antonio; Mønster, Jacob; Samuelsson, Jerker

    2018-01-01

    The tracer gas dispersion method (TDM) is a remote sensing method used for quantifying fugitive emissions by relying on the controlled release of a tracer gas at the source, combined with concentration measurements of the tracer and target gas plumes. The TDM was tested at a wastewater treatment...... plant for plant-integrated methane emission quantification, using four analytical instruments simultaneously and four different tracer gases. Measurements performed using a combination of an analytical instrument and a tracer gas, with a high ratio between the tracer gas release rate and instrument...... precision (a high release-precision ratio), resulted in well-defined plumes with a high signal-to-noise ratio and a high methane-to-tracer gas correlation factor. Measured methane emission rates differed by up to 18% from the mean value when measurements were performed using seven different instrument...

  18. Asian Tracer Experiment and Atmospheric Modeling (TEAM) Project: Draft Field Work Plan for the Asian Long-Range Tracer Experiment

    Energy Technology Data Exchange (ETDEWEB)

    Allwine, K Jerry; Flaherty, Julia E.

    2007-08-01

    This report provides an experimental plan for a proposed Asian long-range tracer study as part of the international Tracer Experiment and Atmospheric Modeling (TEAM) Project. The TEAM partners are China, Japan, South Korea and the United States. Optimal times of year to conduct the study, meteorological measurements needed, proposed tracer release locations, proposed tracer sampling locations and the proposed durations of tracer releases and subsequent sampling are given. Also given are the activities necessary to prepare for the study and the schedule for completing the preparation activities leading to conducting the actual field operations. This report is intended to provide the TEAM members with the information necessary for planning and conducting the Asian long-range tracer study. The experimental plan is proposed, at this time, to describe the efforts necessary to conduct the Asian long-range tracer study, and the plan will undoubtedly be revised and refined as the planning goes forward over the next year.

  19. TU-H-CAMPUS-TeP1-05: Fast Processed 3D Printing-Aided Urethane Resin (PUR) Bolus in Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, B; Chiu, T; Gu, X; Lee, H; Nedzi, L; Jiang, S [UT Southwestern Medical Center, Dallas, TX (United States)

    2016-06-15

    Purpose: 3D printed custom bolus is regularly used in radiation therapy clinic as a compensator. However, usual method of bolus printing with 100% filling is very time-consuming. The purpose of this study is to evaluate the feasibility and benefit of 3D printed bolus filled with UR. Methods: Two boluses were designed on nose (9e electrons) and ear (6× photons) for a head phantom in treatment planning system (TPS) to achieve dose coverage to the skin. The bolus structures (56–167cc) were converted to STereoLithographic (STL) model using an in-house developed algorithm and sent to a commercial fused deposition modeling (FDM) printer. Only shells were printed with polylactic acid (PLA) material. Liquid UR was then placed in a vacuum pump and slowly poured into the hollow bolus from its top opening. Liquid UR hardened in around half an hour. The phantom was rescanned with custom boluses attached and the dosimetry was compared with original design in TPS. Basic CT and dose properties were investigated. GaF films were irradiated to measure dose profile and output of several open photon and electron beams under solid water and UR slabs of same thicknesses. Results: CT number was 11.2±7.3 and 65.4±7.8, respectively for solid water(∼1.04g/cc) and UR(∼1.08g/cc). The output measurement at dmax for 6× was within 2% for the two materials. The relative dose profiles of the two materials above dmax show 94–99% Gamma analysis passing rates for both photons and electrons. Dose distributions with 3D PUR boluses maintained great coverage on the intended skin regions and resembled that with computer generated boluses. Manufacturing 3D PUR boluses was 3–4 times faster than 100% printed boluses. The efficiency significantly improves for larger boluses. Conclusion: The study suggests UR has similar dose responses as solid water. Making custom bolus with UR greatly increases clinical workflow efficiency.

  20. TU-H-CAMPUS-TeP1-05: Fast Processed 3D Printing-Aided Urethane Resin (PUR) Bolus in Radiation Therapy

    International Nuclear Information System (INIS)

    Zhao, B; Chiu, T; Gu, X; Lee, H; Nedzi, L; Jiang, S

    2016-01-01

    Purpose: 3D printed custom bolus is regularly used in radiation therapy clinic as a compensator. However, usual method of bolus printing with 100% filling is very time-consuming. The purpose of this study is to evaluate the feasibility and benefit of 3D printed bolus filled with UR. Methods: Two boluses were designed on nose (9e electrons) and ear (6× photons) for a head phantom in treatment planning system (TPS) to achieve dose coverage to the skin. The bolus structures (56–167cc) were converted to STereoLithographic (STL) model using an in-house developed algorithm and sent to a commercial fused deposition modeling (FDM) printer. Only shells were printed with polylactic acid (PLA) material. Liquid UR was then placed in a vacuum pump and slowly poured into the hollow bolus from its top opening. Liquid UR hardened in around half an hour. The phantom was rescanned with custom boluses attached and the dosimetry was compared with original design in TPS. Basic CT and dose properties were investigated. GaF films were irradiated to measure dose profile and output of several open photon and electron beams under solid water and UR slabs of same thicknesses. Results: CT number was 11.2±7.3 and 65.4±7.8, respectively for solid water(∼1.04g/cc) and UR(∼1.08g/cc). The output measurement at dmax for 6× was within 2% for the two materials. The relative dose profiles of the two materials above dmax show 94–99% Gamma analysis passing rates for both photons and electrons. Dose distributions with 3D PUR boluses maintained great coverage on the intended skin regions and resembled that with computer generated boluses. Manufacturing 3D PUR boluses was 3–4 times faster than 100% printed boluses. The efficiency significantly improves for larger boluses. Conclusion: The study suggests UR has similar dose responses as solid water. Making custom bolus with UR greatly increases clinical workflow efficiency.

  1. THE 2011 PERIASTRON PASSAGE OF THE Be BINARY {delta} Scorpii

    Energy Technology Data Exchange (ETDEWEB)

    Miroshnichenko, A. S. [Department of Physics and Astronomy, University of North Carolina at Greensboro, Greensboro, NC 27402-6170 (United States); Pasechnik, A. V. [Tuorla Observatory, Department of Physics and Astronomy, University of Turku, FI-21500 Puekkioe (Finland); Manset, N. [CFHT Corporation, 65-1238 Mamalahoa Hwy, Kamuela, HI 96743 (United States); Carciofi, A. C. [Instituto de Astronomia, Geofisica e Ciencias Atmosfericas, Universidade de Sao Paulo (Brazil); Rivinius, Th. [European Organisation for Astronomical Research in the Southern Hemisphere, Casilla 19001, Santiago 19 (Chile); Stefl, S. [ESO/ALMA, Alonso de Cordova 3107, Vitacura, Santiago (Chile); Gvaramadze, V. V. [Sternberg Astronomical Institute, Lomonosov Moscow State University, Universitetskij Pr. 13, Moscow 119992 (Russian Federation); Ribeiro, J. [Observatorio do Instituto Geografico do Exercito, Lisboa (Portugal); Fernando, A. [ATALAIA.org Group, Lisboa (Portugal); Garrel, T. [Observatoire de Juvignac, 19 avenue de Hameau du Golf F-34990, Juvignac (France); Knapen, J. H. [Instituto de Astrofisica de Canarias, E-38205 La Laguna, Tenerife (Spain); Buil, C. [Castanet Tolosan Observatory, 6 place Clemence Isaure F-31320 Castanet Tolosan (France); Heathcote, B. [Barfold Observatory, Glenhope, Victoria 3444 (Australia); Pollmann, E. [Emil-Nolde-Str. 12, D-51375, Leverkusen (Germany); Mauclaire, B. [Observatoire du Val d' Arc, route de Peynier F-13530, Trets (France); Thizy, O. [Shelyak Instruments, 1116 route de Chambery, F-38330, Saint-Ismier (France); Martin, J. [Barber Research Observatory, Department of Physics and Astronomy, University of Illinois-Springfield, IL 62703 (United States); Zharikov, S. V. [Instituto de Astronomia, Universidad Nacional Autonoma de Mexico, Apdo. Postal 877, Ensenada, 22800, Baja California (Mexico); Okazaki, A. T. [Faculty of Engineering, Hokkai-Gakuen University, Toyohira-ku, Sapporo 062-8605 (Japan); others, and

    2013-04-01

    We describe the results of the world-wide observing campaign of the highly eccentric Be binary system {delta} Scorpii 2011 periastron passage which involved professional and amateur astronomers. Our spectroscopic observations provided a precise measurement of the system orbital period at 10.8092 {+-} 0.0005 yr. Fitting of the He II 4686 A line radial velocity curve determined the periastron passage time on 2011 July 3, UT 9:20 with a 0.9-day uncertainty. Both these results are in a very good agreement with recent findings from interferometry. We also derived new evolutionary masses of the binary components (13 and 8.2 M{sub Sun }) and a new distance of 136 pc from the Sun, consistent with the HIPPARCOS parallax. The radial velocity and profile variations observed in the H{alpha} line near the 2011 periastron reflected the interaction of the secondary component and the circumstellar disk around the primary component. Using these data, we estimated a disk radius of 150 R{sub Sun }. Our analysis of the radial velocity variations measured during the periastron passage time in 2000 and 2011 along with those measured during the 20th century, the high eccentricity of the system, and the presence of a bow shock-like structure around it suggest that {delta} Sco might be a runaway triple system. The third component should be external to the known binary and move on an elliptical orbit that is tilted by at least 40 Degree-Sign with respect to the binary orbital plane for such a system to be stable and responsible for the observed long-term radial velocity variations.

  2. THE 2011 PERIASTRON PASSAGE OF THE Be BINARY δ Scorpii

    International Nuclear Information System (INIS)

    Miroshnichenko, A. S.; Pasechnik, A. V.; Manset, N.; Carciofi, A. C.; Rivinius, Th.; Štefl, S.; Gvaramadze, V. V.; Ribeiro, J.; Fernando, A.; Garrel, T.; Knapen, J. H.; Buil, C.; Heathcote, B.; Pollmann, E.; Mauclaire, B.; Thizy, O.; Martin, J.; Zharikov, S. V.; Okazaki, A. T.

    2013-01-01

    We describe the results of the world-wide observing campaign of the highly eccentric Be binary system δ Scorpii 2011 periastron passage which involved professional and amateur astronomers. Our spectroscopic observations provided a precise measurement of the system orbital period at 10.8092 ± 0.0005 yr. Fitting of the He II 4686 Å line radial velocity curve determined the periastron passage time on 2011 July 3, UT 9:20 with a 0.9-day uncertainty. Both these results are in a very good agreement with recent findings from interferometry. We also derived new evolutionary masses of the binary components (13 and 8.2 M ☉ ) and a new distance of 136 pc from the Sun, consistent with the HIPPARCOS parallax. The radial velocity and profile variations observed in the Hα line near the 2011 periastron reflected the interaction of the secondary component and the circumstellar disk around the primary component. Using these data, we estimated a disk radius of 150 R ☉ . Our analysis of the radial velocity variations measured during the periastron passage time in 2000 and 2011 along with those measured during the 20th century, the high eccentricity of the system, and the presence of a bow shock-like structure around it suggest that δ Sco might be a runaway triple system. The third component should be external to the known binary and move on an elliptical orbit that is tilted by at least 40° with respect to the binary orbital plane for such a system to be stable and responsible for the observed long-term radial velocity variations.

  3. Reaction paths based on mean first-passage times

    International Nuclear Information System (INIS)

    Park, Sanghyun; Sener, Melih K.; Lu Deyu; Schulten, Klaus

    2003-01-01

    Finding representative reaction pathways is important for understanding the mechanism of molecular processes. We propose a new approach for constructing reaction paths based on mean first-passage times. This approach incorporates information about all possible reaction events as well as the effect of temperature. As an application of this method, we study representative pathways of excitation migration in a photosynthetic light-harvesting complex, photosystem I. The paths thus computed provide a complete, yet distilled, representation of the kinetic flow of excitation toward the reaction center, thereby succinctly characterizing the function of the system

  4. Genre Analysis On Reading Passages Grade VII English Textbooks

    OpenAIRE

    Sukma, Ardini Nur

    2010-01-01

    Referring to the latest curriculum, School-Based Curriculum, every English textbook should provide genres based on the level of literacy of each grade. On this paper, I analyzed English textbooks published by Erlangga ?óÔé¼ÔÇ£ English on Sky (EOS), and by Pakar Raya -- Let?óÔé¼Ôäós Talk. This paper focuses on how are the reading passages of the textbooks compatible with ?óÔé¼?ôStandard Isi?óÔé¼?Ø?. Coinciding with the statement of the problems, the objectives of this paper are to describe the...

  5. First-passage time: a conception leading to superstatistics

    Directory of Open Access Journals (Sweden)

    V.V.Ryazanov

    2006-01-01

    Full Text Available To describe the nonequilibrium states of a system we introduce a new thermodynamic parameter -- the lifetime (the first passage time of a system. The statistical distributions that can be obtained out of the mesoscopic description characterizing the behaviour of a system by specifying the stochastic processes are written. Superstatistics, introduced in [Beck C., Cohen E.G.D., Physica A, 2003, 322A, 267] as fluctuating quantities of intensive thermodynamical parameters, are obtained from statistical distribution with lifetime (random time to system degeneracy as thermodynamical parameter (and also generalization of superstatistics.

  6. Stimulated Raman adiabatic passage in Tm3+:YAG

    International Nuclear Information System (INIS)

    Alexander, A. L.; Lauro, R.; Louchet, A.; Chaneliere, T.; Le Goueet, J. L.

    2008-01-01

    We report on the experimental demonstration of stimulated Raman adiabatic passage in a Tm 3+ :YAG crystal. Tm 3+ :YAG is a promising material for use in quantum information processing applications, but as yet there are few experimental investigations of coherent Raman processes in this material. We investigate the effect of inhomogeneous broadening and Rabi frequency on the transfer efficiency and the width of the two-photon spectrum. Simulations of the complete Tm 3+ :YAG system are presented along with the corresponding experimental results

  7. An extraction machine for the passage of a chamber

    Energy Technology Data Exchange (ETDEWEB)

    Ponomarev, B Ia; Krupnik, V S; Krut, V S; Nenakhov, D F; Niugai, M V; Sagatov, B S

    1980-05-18

    The subject of the invention is the extraction machine for the passage of a chamber with a direct path of a narrow face and the reverse path of a wide face, comprising an actuation unit, a drive reducer, a shield and hydraulic jack for the control brush, is characterized in that for the purpose of insuring the effectiveness of the overlapping, the zones for the loading of the brushes are equipped with chains, whose one end is reinforced on it in a hinge-like fashion, and the other, on the reducer, with which one of the chains is connected to the hydraulic jack by the control brush.

  8. CityFlux perfluorocarbon tracer experiments

    Directory of Open Access Journals (Sweden)

    F. K. Petersson

    2010-07-01

    Full Text Available In June 2006, two perfluorocarbon tracer experiments were conducted in central Manchester UK as part of the CityFlux campaign. The main aim was to investigate vertical dispersion in an urban area during convective conditions, but dispersion mechanisms within the street network were also studied. Paired receptors were used in most cases where one receptor was located at ground level and one at roof level. One receptor was located on the roof of Portland Tower which is an 80 m high building in central Manchester. Source receptor distances in the two experiments varied between 120 and 600 m.

    The results reveal that maximum concentration was sometimes found at roof level rather than at ground level implying the effectiveness of convective forces on dispersion. The degree of vertical dispersion was found to be dependent on source receptor distance as well as on building height in proximity to the release site.

    Evidence of flow channelling in a street canyon was also found. Both a Gaussian profile and a street network model were applied and the results show that the urban topography may lead to highly effective flow channelling which therefore may be a very important dispersion mechanism should the right meteorological conditions prevail.

    The experimental results from this campaign have also been compared with a simple urban dispersion model that was developed during the DAPPLE framework and show good agreement with this.

    The results presented here are some of the first published regarding vertical dispersion. More tracer experiments are needed in order to further characterise vertical concentration profiles and their dependence on, for instance, atmospheric stability. The impact of urban topography on pollutant dispersion is important to focus on in future tracer experiments in order to improve performance of models as well as for our understanding of the relationship between air quality and public health.

  9. CityFlux perfluorocarbon tracer experiments

    Science.gov (United States)

    Petersson, F. K.; Martin, D.; White, I. R.; Henshaw, S. J.; Nickless, G.; Longley, I.; Percival, C. J.; Gallagher, M.; Shallcross, D. E.

    2010-07-01

    In June 2006, two perfluorocarbon tracer experiments were conducted in central Manchester UK as part of the CityFlux campaign. The main aim was to investigate vertical dispersion in an urban area during convective conditions, but dispersion mechanisms within the street network were also studied. Paired receptors were used in most cases where one receptor was located at ground level and one at roof level. One receptor was located on the roof of Portland Tower which is an 80 m high building in central Manchester. Source receptor distances in the two experiments varied between 120 and 600 m. The results reveal that maximum concentration was sometimes found at roof level rather than at ground level implying the effectiveness of convective forces on dispersion. The degree of vertical dispersion was found to be dependent on source receptor distance as well as on building height in proximity to the release site. Evidence of flow channelling in a street canyon was also found. Both a Gaussian profile and a street network model were applied and the results show that the urban topography may lead to highly effective flow channelling which therefore may be a very important dispersion mechanism should the right meteorological conditions prevail. The experimental results from this campaign have also been compared with a simple urban dispersion model that was developed during the DAPPLE framework and show good agreement with this. The results presented here are some of the first published regarding vertical dispersion. More tracer experiments are needed in order to further characterise vertical concentration profiles and their dependence on, for instance, atmospheric stability. The impact of urban topography on pollutant dispersion is important to focus on in future tracer experiments in order to improve performance of models as well as for our understanding of the relationship between air quality and public health.

  10. PIV tracer behavior on propagating shock fronts

    International Nuclear Information System (INIS)

    Glazyrin, Fyodor N; Mursenkova, Irina V; Znamenskaya, Irina A

    2016-01-01

    The present work was aimed at the quantitative particle image velocimetry (PIV) measurement of a velocity field near the front of a propagating shock wave and the study of the dynamics of liquid tracers crossing the shock front. For this goal, a shock tube with a rectangular cross-section (48  ×  24 mm) was used. The flat shock wave with Mach numbers M  =  1.4–2.0 propagating inside the tube channel was studied as well as an expanding shock wave propagating outside the channel with M  =  1.2–1.8 at its main axis. The PIV imaging of the shock fronts was carried out with an aerosol of dioctyl sebacate (DEHS) as tracer particles. The pressures of the gas in front of the shock waves studied ranged from 0.013 Mpa to 0.1 MPa in the series of experiments. The processed PIV data, compared to the 1D normal shock theory, yielded consistent values of wake velocity immediately behind the plain shock wave. Special attention was paid to the blurring of the velocity jump on the shock front due to the inertial particle lag and peculiarities of the PIV technique. A numerical algorithm was developed for analysis and correction of the PIV data on the shock fronts, based on equations of particle-flow interaction. By application of this algorithm, the effective particle diameter of the DEHS aerosol tracers was estimated as 1.03  ±  0.12 μm. A number of different formulations for particle drag were tested with this algorithm, with varying success. The results show consistency with previously reported experimental data obtained for cases of stationary shock waves. (paper)

  11. Radiation dermatitis caused by a bolus effect from an abdominal compression device

    Energy Technology Data Exchange (ETDEWEB)

    Connor, Michael; Wei, Randy L.; Yu, Suhong; Sehgal, Varun [Department of Radiation Oncology, University of California, Irvine Medical Center, Orange, CA (United States); Klempner, Samuel J. [Department of Medicine, Division of Hematology/Oncology, University of California, Orange, CA (United States); Daroui, Parima, E-mail: pdaroui@uci.edu [Department of Radiation Oncology, University of California, Irvine Medical Center, Orange, CA (United States)

    2016-10-01

    American Association of Physicists in Medicine (AAPM) Task Group 176 evaluated the dosimetric effects caused by couch tops and immobilization devices. The report analyzed the extensive physics-based literature on couch tops, stereotactic body radiation therapy (SBRT) frames, and body immobilization bags, while noting the scarcity of clinical reports of skin toxicity because of external devices. Here, we present a clinical case report of grade 1 abdominal skin toxicity owing to an abdominal compression device. We discuss the dosimetric implications of the utilized treatment plan as well as post hoc alternative plans and quantify differences in attenuation and skin dose/build-up between the device, a lower-density alternative device, and an open field. The description of the case includes a 66-year-old male with HER2 amplified poorly differentiated distal esophageal adenocarcinoma treated with neoadjuvant chemo-radiation and the use of an abdominal compression device. Radiation was delivered using volumetric modulated arc therapy (VMAT) with 2 arcs using abdominal compression and image guidance. The total dose was 50.4 Gy delivered over 40 elapsed days. With 2 fractions remaining, the patient developed dermatitis in the area of the compression device. The original treatment plan did not include a contour of the device. Alternative post hoc treatment plans were generated, one to contour the device and a second with anterior avoidance. In conclusion, replanning with the device contoured revealed the bolus effect. The skin dose increased from 27 to 36 Gy. planned target volume (PTV) coverage at 45 Gy was reduced to 76.5% from 95.8%. The second VMAT treatment plan with an anterior avoidance sector and more oblique beam angles maintained PTV coverage and spared the anterior wall, however at the expense of substantially increased dose to lung. This case report provides an important reminder of the bolus effect from external devices such as abdominal compression. Special

  12. Radiation dermatitis caused by a bolus effect from an abdominal compression device

    International Nuclear Information System (INIS)

    Connor, Michael; Wei, Randy L.; Yu, Suhong; Sehgal, Varun; Klempner, Samuel J.; Daroui, Parima

    2016-01-01

    American Association of Physicists in Medicine (AAPM) Task Group 176 evaluated the dosimetric effects caused by couch tops and immobilization devices. The report analyzed the extensive physics-based literature on couch tops, stereotactic body radiation therapy (SBRT) frames, and body immobilization bags, while noting the scarcity of clinical reports of skin toxicity because of external devices. Here, we present a clinical case report of grade 1 abdominal skin toxicity owing to an abdominal compression device. We discuss the dosimetric implications of the utilized treatment plan as well as post hoc alternative plans and quantify differences in attenuation and skin dose/build-up between the device, a lower-density alternative device, and an open field. The description of the case includes a 66-year-old male with HER2 amplified poorly differentiated distal esophageal adenocarcinoma treated with neoadjuvant chemo-radiation and the use of an abdominal compression device. Radiation was delivered using volumetric modulated arc therapy (VMAT) with 2 arcs using abdominal compression and image guidance. The total dose was 50.4 Gy delivered over 40 elapsed days. With 2 fractions remaining, the patient developed dermatitis in the area of the compression device. The original treatment plan did not include a contour of the device. Alternative post hoc treatment plans were generated, one to contour the device and a second with anterior avoidance. In conclusion, replanning with the device contoured revealed the bolus effect. The skin dose increased from 27 to 36 Gy. planned target volume (PTV) coverage at 45 Gy was reduced to 76.5% from 95.8%. The second VMAT treatment plan with an anterior avoidance sector and more oblique beam angles maintained PTV coverage and spared the anterior wall, however at the expense of substantially increased dose to lung. This case report provides an important reminder of the bolus effect from external devices such as abdominal compression. Special

  13. WE-F-16A-05: Use of 3D-Printers to Create a Tissue Equivalent 3D-Bolus for External Beam Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Burleson, S; Baker, J; Hsia, A; Xu, Z [Stony Brook Medicine, Stony Brook, NY (United States)

    2014-06-15

    Purpose: The purpose of this project is to demonstrate that a non-expensive 3D-printer can be used to manufacture a 3D-bolus for external beam therapy. The printed bolus then can be modeled in our treatment planning system to ensure accurate dose delivery to the patient. Methods: We developed a simple method to manufacture a patient-specific custom 3Dbolus. The bolus is designed using Eclipse Treatment Planning System, contoured onto the patients CT images. The bolus file is exported from Eclipse to 3D-printer software, and then printed using a 3D printer. Various tests were completed to determine the properties of the printing material. Percent depth dose curves in this material were measured with electron and photon beams for comparison to other materials. In order to test the validity of the 3D printed bolus for treatment planning, a custom bolus was printed and tested on the Rando phantom using film for a dose plane comparison. We compared the dose plane measured on the film to the same dose plane exported from our treatment planning system using Film QA software. The gamma-dose distribution tool was used in our film analysis. Results: We compared point measurements throughout the dose plane and were able to achieve greater than 95% passing rate at 3% dose difference and 3 mm distance to agreement, which is our departments acceptable gamma pixel parameters. Conclusion: The printed 3D bolus has proven to be accurately modeled in our treatment planning system, it is more conformal to the patient surface and more durable than other bolus currently used (wax, superflab etc.). It is also more convenient and less costly than comparable bolus from milling machine companies.

  14. WE-F-16A-05: Use of 3D-Printers to Create a Tissue Equivalent 3D-Bolus for External Beam Therapy

    International Nuclear Information System (INIS)

    Burleson, S; Baker, J; Hsia, A; Xu, Z

    2014-01-01

    Purpose: The purpose of this project is to demonstrate that a non-expensive 3D-printer can be used to manufacture a 3D-bolus for external beam therapy. The printed bolus then can be modeled in our treatment planning system to ensure accurate dose delivery to the patient. Methods: We developed a simple method to manufacture a patient-specific custom 3Dbolus. The bolus is designed using Eclipse Treatment Planning System, contoured onto the patients CT images. The bolus file is exported from Eclipse to 3D-printer software, and then printed using a 3D printer. Various tests were completed to determine the properties of the printing material. Percent depth dose curves in this material were measured with electron and photon beams for comparison to other materials. In order to test the validity of the 3D printed bolus for treatment planning, a custom bolus was printed and tested on the Rando phantom using film for a dose plane comparison. We compared the dose plane measured on the film to the same dose plane exported from our treatment planning system using Film QA software. The gamma-dose distribution tool was used in our film analysis. Results: We compared point measurements throughout the dose plane and were able to achieve greater than 95% passing rate at 3% dose difference and 3 mm distance to agreement, which is our departments acceptable gamma pixel parameters. Conclusion: The printed 3D bolus has proven to be accurately modeled in our treatment planning system, it is more conformal to the patient surface and more durable than other bolus currently used (wax, superflab etc.). It is also more convenient and less costly than comparable bolus from milling machine companies

  15. Survey on industrial applications of radioactive tracers

    International Nuclear Information System (INIS)

    Kim, Jae Rok; Yoo, Young Soo; Lee, Jong Doo; Awh, Ok Doo; Kim, Jun Hyung

    1986-12-01

    Current status and future feasibilities of industrial tracer applications in the Republic of Korea have been surveyed. Microleak detection using Krypton-85 in eight electronics industrial companies, and efficiency tests of steam generators in four nuclear power plants using Sodium-24 are the principal applications in Korea. Future applications are expected for mercury inventory in one soda industrial company, and alkali movement studies in two cement industrial companies. Korean industries expressed deep interest in leak detection in underground pipelines, abrasion/corrosion studies, mixing rate and residence time measurements. (Author)

  16. Pharmaceuticals as Groundwater Tracers - Applications and Limitations

    Science.gov (United States)

    Scheytt, T. J.; Mersmann, P.; Heberer, T.

    2003-12-01

    Pharmaceutically active substances and metabolites are found at concentrations up to the microgram/L-level in groundwater samples from the Berlin (Germany) area and from several other places world wide. Among the compounds detected in groundwater are clofibric acid, propyphenazone, diclofenac, ibuprofen, and carbamazepine. Clofibric acid, the active metabolite of clofibrate and etofibrate (blood lipid regulators) is detected in groundwater at maximum concentrations of 7300 ng/L. Among the most important input paths of drugs are excretion and disposal into the sewage system. Groundwater contamination is likely to be due to leaky sewage systems, influent streams, bank filtration, and irrigation with effluent water from sewage treatment plants. There are no known natural sources of the above mentioned pharmaceuticals. The use of pharmaceuticals as tracers may include: (a) Quantification of infiltration from underground septic tanks (b) Detection of leaky sewage systems / leaky sewage pipes (c) Estimation of the effectiveness of sewage treatment plants (d) Identification of transport pathways of other organic compounds (e) Quantification of surface water / groundwater interaction (f) Characterization of the biodegradation potential. The use of pharmaceuticals as tracers is limited by variations in input. These variations depend on the amount of drugs prescribed and used in the study area, the social structure of the community, the amount of hospital discharge, and temporal concentration variations. Furthermore, the analysis of trace amounts of pharmaceuticals is sophisticated and expensive and may therefore limit the applicability of pharmaceuticals as tracers. Finally, the transport and degradation behavior of pharmaceuticals is not fully understood. Preliminary experiments in the laboratory were conducted using sediment material and groundwater from the Berlin area to evaluate the transport and sorption behavior of selected drugs. Results of the column experiments

  17. Tracer preparate and method for its production

    International Nuclear Information System (INIS)

    Pratt, F.P.; Gagnon, D.

    1978-01-01

    The injectable tracer preparate for investigations to determine the blood flow in organs or the effect of drugs on the blood flow consists of a core of ion exchanger resin coated with polyfuran or a polymer which is the reaction product of a monomer catalysable by acid or base. The nuclei have a diameter of 10 to 200 micron, the coating thickness is between 1 and 3 micron. Ions of Ce 141, Cr 51, Sr 85, Sr 46 or Co 57 of strength 0.1-100 millicurie are adsorbed on the nucleus. (DG) [de

  18. Tracer techniques in estimating nuclear materials holdup

    International Nuclear Information System (INIS)

    Pillay, K.K.S.

    1987-01-01

    Residual inventory of nuclear materials remaining in processing facilities (holdup) is recognized as an insidious problem for safety of plant operations and safeguarding of special nuclear materials (SNM). This paper reports on an experimental study where a well-known method of radioanalytical chemistry, namely tracer technique, was successfully used to improve nondestructive measurements of holdup of nuclear materials in a variety of plant equipment. Such controlled measurements can improve the sensitivity of measurements of residual inventories of nuclear materials in process equipment by several orders of magnitude and the good quality data obtained lend themselves to developing mathematical models of holdup of SNM during stable plant operations

  19. The influence of carbon monoxide bolus on the measurement of total haemoglobin mass using the optimized CO-rebreathing method

    International Nuclear Information System (INIS)

    Turner, G; Richardson, A J; Maxwell, N S; Pringle, J S M; Ingham, S A; Fudge, B W

    2014-01-01

    The optimized carbon monoxide (CO) rebreathing method (oCOR-method) is routinely used to measure total haemoglobin mass (tHbmass). The tHbmass measure is subject to a test-retest typical error of ∼2%, mostly from the precision of carboxyhaemoglobin (HbCO) measurement. We hypothesized that tHbmass would be robust to differences in the bolus of CO administered during the oCOR-method. Twelve participants (ten males and two females; age 27 ± 6 yr, height 177 ± 11 cm and mass 73.9 ± 12.1 kg) completed the oCOR-method on four occasions. Different bolus of CO were administered (LOW: 0.6 ml kg −1 ; MED 1 : 1.0 ml kg −1  and HIGH: 1.4 ml kg −1 ); to determine the reliability of MED 1 , a second trial was conducted (MED 2 ). tHbmass was found to be significantly less from the HIGH CO bolus (776 ± 148 g) when compared to the LOW CO (791 ± 149 g) or MED 1  CO (788 ± 149 g) trials. MED 2  CO was 785 ± 150 g. The measurement of tHbmass is repeatable to within 0.8%, but a small and notable difference was seen when using a HIGH CO bolus (1.4 to 1.9% less), potentially due to differences in CO uptake kinetics. Previously, an improved precision of the oCOR-method was thought to require a higher bolus of CO (i.e. larger ▵%HbCO), as commercial hemoximeters only estimate %HbCO levels to a single decimal place (usually ± 0.1%). With the new hemoximeter used in this study, a bolus of 1.0 ml kg −1  allows adequate precision with acceptable safety. (note)

  20. Continuous versus bolus intragastric tube feeding for preterm and low birth weight infants with gastro-oesophageal reflux disease.

    Science.gov (United States)

    Richards, Robyn; Foster, Jann P; Psaila, Kim

    2014-07-17

    Gastro-oesophageal reflux disease is a particularly common condition in preterm and low birth weight infants. These infants are also more likely to have excessive regurgitation, as they do not have a fully developed antireflux mechanism. Preterm and low birth weight infants who are unable to suck oral feeds are required to be fed via an intragastric tube for varying lengths of time. Intragastric tube feeding can be delivered by the intermittent bolus or continuous feeding method. Use of continuous or intermittent bolus intragastric feeding may have a positive or negative effect on the incidence or severity of gastro-oesophageal reflux disease. To determine whether continuous or intermittent bolus intragastric tube feeding reduces the number of episodes and the duration of gastro-oesophageal reflux disease (GORD) in preterm and low birth weight infants.We intended to perform subgroup analyses for gestational age; birth weight; age in days from birth at full enteral feeding via intragastric tube (breast vs bottle); frequency of intermittent bolus feed; and type of medication for treatment of GORD (only if medication prescribed and given similarly to both intervention groups). We used the standard search strategy of the Cochrane Neonatal Group as described in The Cochrane Library (www.thecochranelibrary.com) to search for randomised controlled trials (RCTs) in the Cochrane Central Register of Controlled Trials (CENTRAL) (2013, Issue 9), MEDLINE (1966 to September 2013), EMBASE (1980 to September 2013) and the Cumulative Index to Nursing and Allied Health Literature (CINAHL) (1982 to September 2013). We also searched previous reviews, including cross-references, abstracts and conference and symposia proceedings of the Perinatal Society of Australia and New Zealand and the Pediatric Academic Societies (American Pediatric Society/Society for Pediatric Research and European Society for Paediatric Research) from 1990 to 2012. Published and unpublished RCTs and quasi

  1. Wireless Sensor Network Deployment for Monitoring Wildlife Passages

    Science.gov (United States)

    Garcia-Sanchez, Antonio-Javier; Garcia-Sanchez, Felipe; Losilla, Fernando; Kulakowski, Pawel; Garcia-Haro, Joan; Rodríguez, Alejandro; López-Bao, José-Vicente; Palomares, Francisco

    2010-01-01

    Wireless Sensor Networks (WSNs) are being deployed in very diverse application scenarios, including rural and forest environments. In these particular contexts, specimen protection and conservation is a challenge, especially in natural reserves, dangerous locations or hot spots of these reserves (i.e., roads, railways, and other civil infrastructures). This paper proposes and studies a WSN based system for generic target (animal) tracking in the surrounding area of wildlife passages built to establish safe ways for animals to cross transportation infrastructures. In addition, it allows target identification through the use of video sensors connected to strategically deployed nodes. This deployment is designed on the basis of the IEEE 802.15.4 standard, but it increases the lifetime of the nodes through an appropriate scheduling. The system has been evaluated for the particular scenario of wildlife monitoring in passages across roads. For this purpose, different schemes have been simulated in order to find the most appropriate network operational parameters. Moreover, a novel prototype, provided with motion detector sensors, has also been developed and its design feasibility demonstrated. Original software modules providing new functionalities have been implemented and included in this prototype. Finally, main performance evaluation results of the whole system are presented and discussed in depth. PMID:22163601

  2. Wireless Sensor Network Deployment for Monitoring Wildlife Passages

    Directory of Open Access Journals (Sweden)

    José-Vicente López-Bao

    2010-08-01

    Full Text Available Wireless Sensor Networks (WSNs are being deployed in very diverse application scenarios, including rural and forest environments. In these particular contexts, specimen protection and conservation is a challenge, especially in natural reserves, dangerous locations or hot spots of these reserves (i.e., roads, railways, and other civil infrastructures. This paper proposes and studies a WSN based system for generic target (animal tracking in the surrounding area of wildlife passages built to establish safe ways for animals to cross transportation infrastructures. In addition, it allows target identification through the use of video sensors connected to strategically deployed nodes. This deployment is designed on the basis of the IEEE 802.15.4 standard, but it increases the lifetime of the nodes through an appropriate scheduling. The system has been evaluated for the particular scenario of wildlife monitoring in passages across roads. For this purpose, different schemes have been simulated in order to find the most appropriate network operational parameters. Moreover, a novel prototype, provided with motion detector sensors, has also been developed and its design feasibility demonstrated. Original software modules providing new functionalities have been implemented and included in this prototype. Finally, main performance evaluation results of the whole system are presented and discussed in depth.

  3. Intermediate-level crossings of a first-passage path

    International Nuclear Information System (INIS)

    Bhat, Uttam; Redner, S

    2015-01-01

    We investigate some simple and surprising properties of a one-dimensional Brownian trajectory with diffusion coefficient D that starts at the origin and: (i) is at X at time T, or (ii) first reaches X at time T. We determine the most likely location of the first-passage trajectory from (0, 0) to (X, T) and its distribution at any intermediate time t < T. A first-passage path typically starts out by being repelled from its final location when X 2 /DT ≪ 1. We also determine the distribution of times when the trajectory first crosses and last crosses an arbitrary intermediate position x < X. The distribution of first-crossing times may be unimodal or bimodal, depending on whether X 2 /DT ≪ 1 or X 2 /DT ≫ 1. The form of the first-crossing probability in the bimodal regime is qualitatively similar to, but more singular than, the well-known arcsine law. (paper)

  4. The Be Binary δ Scorpii and Its 2011 Periastron Passage

    Science.gov (United States)

    Miroshnichenko, A. S.; Manset, N.; Pasechnik, A. V.; Carciofi, A. C.; Rivinius, Th.; Štefl, S.; Ribeiro, J. M.; Fernando, A.; Garrel, T.; Knapen, J. H.; Buil, C.; Heathcote, B.; Pollmann, E.; Thizy, O.; Eversberg, T.; Reinecke, N.; Martin, J.; Okazaki, A. T.; Gandet, T. L.; Gvaramadze, V. V.; Zharikov, S. V.

    2012-12-01

    δ Scorpii is an unusual Be binary system. The binarity was discovered by interferometry in the 1970's and only confirmed by radial velocity measurements during the periastron passage in September 2000, when the primary component became a Be star. The components brightness and mass suggest that both are normal B-type stars. However, the large orbital eccentricity (e = 0.94) is highly uncommon, as most such Be binaries have circular orbits. The orbital period, only recently constrained by interferometry at 10.81 years, needed confirmation from spectroscopy during the last periastron passage in July 2011. The periastron observing campaign that involved professionals and amateurs resulted in obtaining several hundreds of spectra during the period of a large radial velocity change compared to only thirty obtained in 2000. Along with a determination of the orbital period accurate to 3-4 days, the radial velocity curve was found to be more complicated than one expected from just a binary system. I will briefly review the primary's disk development followed by a discussion of the recent observations. Implications for the system properties and ideas for future observations will be presented.

  5. First passage time problems in time-dependent fields

    International Nuclear Information System (INIS)

    Fletcher, J.E.; Havlin, S.; Weiss, G.H.

    1988-01-01

    This paper discusses the simplest first passage time problems for random walks and diffusion processes on a line segment. When a diffusing particle moves in a time-varying field, use of the adjoint equation does not lead to any simplification in the calculation of moments of the first passage time as is the case for diffusion in a time-invariant field. We show that for a discrete random walk in the presence of a sinusoidally varying field there is a resonant frequency omega* for which the mean residence time on the line segment in a minimum. It is shown that for a random walk on a line segment of length L the mean residence time goes like L 2 for large L when omega omega*, but when omega = omega* the dependence is proportional to L. The results of our simulation are numerical, but can be regarded as exact. Qualitatively similar results are shown to hold for diffusion processes by a perturbation expansion in powers of a dimensionless velocity. These results are extended to higher values of this parameter by a numerical solution of the forward equation

  6. A differentiated plane wave: its passage through a slab

    International Nuclear Information System (INIS)

    Hannay, J H; Nye, J F

    2013-01-01

    Differentiating a monochromatic uniform plane electromagnetic wavefield with respect to its direction produces, from a field that is completely lacking in localized specific features, one that contains a straight vortex-like line, a ‘C-line’ of defined circular polarization. There is also a second separate C-line of opposite handedness; indeed, in a sense, a straight line of every polarization is realized. Because of its primitive construction it is analytically simple to study the passage of a differentiated wave obliquely through a plane interface into a medium of different refractive index, to trace its C-line. This was done in an earlier paper. Here we extend the method to passage through a parallel-sided transparent slab. There are multiple reflections within the slab, as in a Fabry–Pérot interferometer. The exiting wave, as a single differentiated plane wave, has a straight oblique C-line. Inside the slab, and in front of it, there is wave interference. The result is a coiled, helix-like, C-line in front of the slab and another inside it. The two coils wrap around separate hyperboloids of one sheet, like cooling towers. The emerging straight C-line is shifted (with respect to a C-line in a notional undisturbed incident plane wave) both in the plane of incidence and transversely to it, and the second C-line behaves similarly. The analysis is exact and could be extended in a straightforward way to a general stratified medium. (paper)

  7. Use of radon as tracer for identification of aquifer discharge along the Matinha stream, MG, Brazil

    International Nuclear Information System (INIS)

    Chagas, Claudio Jose

    2017-01-01

    recover the mass of injected fluorescence tracer was the GGUN FL-30 connected to a notebook so that it could follow the tracer cloud passage. The gamma radiation measurements were fitted with AT6101C detector installed inside a backpack so that they could be scanned along the thalweg and along the banks of the stream. The results showed the presence of significant amounts of the radioisotope in several sections of Matinha stream, which indicates the interconnection between the groundwater and the surface waters. This interconnection with aquifers justifies the increase of the flows found between upstream and downstream of the sections with larger activities of "2"2"2Rn, since there were no other superficial contributions along the section studied. The gamma radiation found denotes proximity to the base rock along with the minerals brought by the groundwater and sedimented on the flood surfaces. (author)

  8. Fish Passage Center : Fish Passage Center of the Columbia Basin Fish and Wildlife Authority; Annual report 1998

    International Nuclear Information System (INIS)

    DeHart, Michele

    1999-01-01

    The 1998 operations of the Columbia and Snake rivers system illustrated that there was potential flexibility in the operation of the hydrosystem to improve fish passage for juvenile salmon and increase the degree to which the NMS Biological Opinion measures could have been implemented successfully. This additional flexibility was not exercised. Some measures of the Biological Opinion were not implemented. The 1998 operation showed that the Hells Canyon Complex, operation, the Upper Snake River operation and Non-treaty storage operation could have provided flexibility to meet early spring and later summer flows

  9. Measurements of waste tank passive ventilation rates using tracer gases

    International Nuclear Information System (INIS)

    Huckaby, J.L.; Olsen, K.B.; Sklarew, D.S.; Evans, J.C.; Remund, K.M.

    1997-09-01

    This report presents the results of ventilation rate studies of eight passively ventilated high-level radioactive waste tanks using tracer gases. Head space ventilation rates were determined for Tanks A-101, AX-102, AX-103, BY-105, C-107, S-102, U-103, and U-105 using sulfur hexafluoride (SF 6 ) and/or helium (He) as tracer gases. Passive ventilation rates are needed for the resolution of several key safety issues. These safety issues are associated with the rates of flammable gas production and ventilation, the rates at which organic salt-nitrate salt mixtures dry out, and the estimation of organic solvent waste surface areas. This tracer gas study involves injecting a tracer gas into the tank headspace and measuring its concentration at different times to establish the rate at which the tracer is removed by ventilation. Tracer gas injection and sample collection were performed by SGN Eurisys Service Corporation and/or Lockheed Martin Hanford Corporation, Characterization Project Operations. Headspace samples were analyzed for He and SF 6 by Pacific Northwest National Laboratory (PNNL). The tracer gas method was first demonstrated on Tank S-102. Tests were conducted on Tank S-102 to verify that the tracer gas was uniformly distributed throughout the tank headspace before baseline samples were collected, and that mixing was sufficiently vigorous to maintain an approximately uniform distribution of tracer gas in the headspace during the course of the study. Headspace samples, collected from a location about 4 in away from the injection point and 15, 30, and 60 minutes after the injection of He and SF 6 , indicated that both tracer gases were rapidly mixed. The samples were found to have the same concentration of tracer gases after 1 hour as after 24 hours, suggesting that mixing of the tracer gas was essentially complete within 1 hour

  10. Chemotherapeutic agent and tracer composition and use thereof

    International Nuclear Information System (INIS)

    Babb, A. L.

    1985-01-01

    A therapeutic composition suitable for extracorporeal treatment of whole blood comprises a dialyzable chemotherapeutic agent and a dialyzable fluorescable tracer means. The removal rate of the fluorescable tracer compound from treated blood during hemodialysis is a function of the removal rate of unreacted chemotherapeutic agent present. The residual chemotherapeutic agent concentration after hemodialysis is ascertained by measuring the concentration of the fluorescable tracer compound in a dialysate using fluorometric techniques

  11. Atmospheric Gas Tracers in Groundwater: Theory, Sampling. Measurement and Interpretation

    International Nuclear Information System (INIS)

    Bayari, C.S.

    2002-01-01

    Some of the atmospheric gasses posses features that are sought in an environmental tracer of hydrogeologic interest. Among these, chlorofluorocarbons, sulfur hegzafluoride, carbon tetrachloride, methyl chloroform, krypton-85 etc. have found increasing use in groundwater age dating studies during the last ten years. This paper explains the theory of their use as tracer and discusses the major concerns as related to their sampling and analyses. Factors affecting their applicability and the approach to interpret tracer gas data is briefly outlined

  12. Dosimetry characterization and clinical application of Exa skin: Bolus of high of high density for use with photons; Caracterizacion dosimetrica y aplicacion clinica de Exaskin: bolus de alta densidad para uso con fotones

    Energy Technology Data Exchange (ETDEWEB)

    Ortiz Seidel, M.; Velazquez Miranda, S.

    2013-07-01

    Bolus of high density eXaSkin of density 1.6 g/cm{sub 3} is calculated correctly in the planning systems, is easy to use and generates optimum coupling with the radiation area, at the same time which is easily reproducible in their placement, avoiding the use of electron beams. On the other hand its behavior varies very slightly with the presence of air gaps. (Author)

  13. Compilation and analyses of results from cross-hole tracer tests with conservative tracers

    Energy Technology Data Exchange (ETDEWEB)

    Hjerne, Calle; Nordqvist, Rune; Harrstroem, Johan (Geosigma AB (Sweden))

    2010-09-15

    Radionuclide transport in hydrogeological formations is one of the key factors for the safety analysis of a future repository of nuclear waste. Tracer tests have therefore been an important field method within the SKB investigation programmes at several sites since the late 1970's. This report presents a compilation and analyses of results from cross-hole tracer tests with conservative tracers performed within various SKB investigations. The objectives of the study are to facilitate, improve and reduce uncertainties in predictive tracer modelling and to provide supporting information for SKB's safety assessment of a final repository of nuclear waste. More specifically, the focus of the report is the relationship between the tracer mean residence time and fracture hydraulic parameters, i.e. the relationship between mass balance aperture and fracture transmissivity, hydraulic diffusivity and apparent storativity. For 74 different combinations of pumping and injection section at six different test sites (Studsvik, Stripa, Finnsjoen, Aespoe, Forsmark, Laxemar), estimates of mass balance aperture from cross-hole tracer tests as well as transmissivity were extracted from reports or in the SKB database Sicada. For 28 of these combinations of pumping and injection section, estimates of hydraulic diffusivity and apparent storativity from hydraulic interference tests were also found. An empirical relationship between mass balance aperture and transmissivity was estimated, although some uncertainties for individual data exist. The empirical relationship between mass balance aperture and transmissivity presented in this study deviates considerably from other previously suggested relationships, such as the cubic law and transport aperture as suggested by /Dershowitz and Klise 2002/, /Dershowitz et al. 2002/ and /Dershowitz et al. 2003/, which also is discussed in this report. No clear and direct empirical relationship between mass balance aperture and hydraulic

  14. Tracer Testing for Estimating Heat Transfer Area in Fractured Reservoirs

    Energy Technology Data Exchange (ETDEWEB)

    Pruess, Karsten; van Heel, Ton; Shan, Chao

    2004-05-12

    A key parameter governing the performance and life-time of a Hot Fractured Rock (HFR) reservoir is the effective heat transfer area between the fracture network and the matrix rock. We report on numerical modeling studies into the feasibility of using tracer tests for estimating heat transfer area. More specifically, we discuss simulation results of a new HFR characterization method which uses surface-sorbing tracers for which the adsorbed tracer mass is proportional to the fracture surface area per unit volume. Sorption in the rock matrix is treated with the conventional formulation in which tracer adsorption is volume-based. A slug of solute tracer migrating along a fracture is subject to diffusion across the fracture walls into the adjacent rock matrix. Such diffusion removes some of the tracer from the fluid in the fractures, reducing and retarding the peak in the breakthrough curve (BTC) of the tracer. After the slug has passed the concentration gradient reverses, causing back-diffusion from the rock matrix into the fracture, and giving rise to a long tail in the BTC of the solute. These effects become stronger for larger fracture-matrix interface area, potentially providing a means for estimating this area. Previous field tests and modeling studies have demonstrated characteristic tailing in BTCs for volatile tracers in vapor-dominated reservoirs. Simulated BTCs for solute tracers in single-phase liquid systems show much weaker tails, as would be expected because diffusivities are much smaller in the aqueous than in the gas phase, by a factor of order 1000. A much stronger signal of fracture-matrix interaction can be obtained when sorbing tracers are used. We have performed simulation studies of surface-sorbing tracers by implementing a model in which the adsorbed tracer mass is assumed proportional to the fracture-matrix surface area per unit volume. The results show that sorbing tracers generate stronger tails in BTCs, corresponding to an effective

  15. Performance Testing of Tracer Gas and Tracer Aerosol Detectors for use in Radionuclide NESHAP Compliance Testing

    Energy Technology Data Exchange (ETDEWEB)

    Fuehne, David Patrick [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Lattin, Rebecca Renee [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-06-28

    The Rad-NESHAP program, part of the Air Quality Compliance team of LANL’s Compliance Programs group (EPC-CP), and the Radiation Instrumentation & Calibration team, part of the Radiation Protection Services group (RP-SVS), frequently partner on issues relating to characterizing air flow streams. This memo documents the most recent example of this partnership, involving performance testing of sulfur hexafluoride detectors for use in stack gas mixing tests. Additionally, members of the Rad-NESHAP program performed a functional trending test on a pair of optical particle counters, comparing results from a non-calibrated instrument to a calibrated instrument. Prior to commissioning a new stack sampling system, the ANSI Standard for stack sampling requires that the stack sample location must meet several criteria, including uniformity of tracer gas and aerosol mixing in the air stream. For these mix tests, tracer media (sulfur hexafluoride gas or liquid oil aerosol particles) are injected into the stack air stream and the resulting air concentrations are measured across the plane of the stack at the proposed sampling location. The coefficient of variation of these media concentrations must be under 20% when evaluated over the central 2/3 area of the stack or duct. The instruments which measure these air concentrations must be tested prior to the stack tests in order to ensure their linear response to varying air concentrations of either tracer gas or tracer aerosol. The instruments used in tracer gas and aerosol mix testing cannot be calibrated by the LANL Standards and Calibration Laboratory, so they would normally be sent off-site for factory calibration by the vendor. Operational requirements can prevent formal factory calibration of some instruments after they have been used in hazardous settings, e.g., within a radiological facility with potential airborne contamination. The performance tests described in this document are intended to demonstrate the reliable

  16. The ATLAS DDM Tracer monitoring framework

    CERN Document Server

    ZANG, D; The ATLAS collaboration; BARISITS, M; LASSNIG, M; Andrew STEWART, G; MOLFETAS, A; BEERMANN, T

    2012-01-01

    The DDM Tracer Service is aimed to trace and monitor the atlas file operations on the Worldwide LHC Computing Grid. The volume of traces has increased significantly since the service started in 2009. Now there are about ~5 million trace messages every day and peaks of greater than 250Hz, with peak rates continuing to climb, which gives the current service structure a big challenge. Analysis of large datasets based on on-demand queries to the relational database management system (RDBMS), i.e. Oracle, can be problematic, and have a significant effect on the database's performance. Consequently, We have investigated some new high availability technologies like messaging infrastructure, specifically ActiveMQ, and key-value stores. The advantages of key value store technology are that they are distributed and have high scalability; also their write performances are usually much better than RDBMS, all of which are very useful for the Tracer service. Indexes and distributed counters have been also tested to improve...

  17. Advection and dispersion of bed load tracers

    Science.gov (United States)

    Lajeunesse, Eric; Devauchelle, Olivier; James, François

    2018-05-01

    We use the erosion-deposition model introduced by Charru et al. (2004) to numerically simulate the evolution of a plume of bed load tracers entrained by a steady flow. In this model, the propagation of the plume results from the stochastic exchange of particles between the bed and the bed load layer. We find a transition between two asymptotic regimes. The tracers, initially at rest, are gradually set into motion by the flow. During this entrainment regime, the plume is strongly skewed in the direction of propagation and continuously accelerates while spreading nonlinearly. With time, the skewness of the plume eventually reaches a maximum value before decreasing. This marks the transition to an advection-diffusion regime in which the plume becomes increasingly symmetrical, spreads linearly, and advances at constant velocity. We analytically derive the expressions of the position, the variance, and the skewness of the plume and investigate their asymptotic regimes. Our model assumes steady state. In the field, however, bed load transport is intermittent. We show that the asymptotic regimes become insensitive to this intermittency when expressed in terms of the distance traveled by the plume. If this finding applies to the field, it might provide an estimate for the average bed load transport rate.

  18. The Effect of Rheological Properties of Foods on Bolus Characteristics After Mastication

    Science.gov (United States)

    Hwang, Junah; Bae, Jung Hyun; Kang, Si Hyun; Seo, Kyung Mook; Kim, Byong Ki; Lee, Sook Young

    2012-01-01

    Objective To evaluate the effects of physical properties of foods on the changes of viscosity and mass as well as the particle size distribution after mastication. Method Twenty subjects with no masticatory disorders were recruited. Six grams of four solid foods of different textures (banana, tofu, cooked-rice, cookie) were provided, and the viscosity and mass after 10, 20, and 30 cycles of mastication and just before swallowing were measured. The physical properties of foods, such as hardness, cohesiveness, and adhesiveness, were measured with a texture analyzer. Wet sieving and laser diffraction were used to determine the distribution of food particle size. Results When we measured the physical characteristics of foods, the cookie was the hardest food, and the banana exhibited marked adhesiveness. Tofu and cooked-rice exhibited a highly cohesive nature. As the number of mastication cycles increased, the masses of all foods were significantly increased (pmastication (pmastication process and food bolus formation were affected by the physical properties of the food. PMID:23342309

  19. MnDPDP enhancement in rabbit liver after intravenous bolus injection and slow infusion

    International Nuclear Information System (INIS)

    Thorstensen, Oe.; Isberg, B.; Jorulf, H.; Westman, L.; Svahn, U.; Venizelos, N.

    1997-01-01

    Purpose: To investigate the MR-enhancing effect of mangafodipir trisodium (MnDPDP, Teslascan) in the rabbit liver in relation to dose, mode of administration and imaging window. Material and Methods: MnDPDP was administered to 18 rabbits at a dose of 10 μmol/kg or 20 μmol/kg, as a bolus injection or infusion. MR imaging of the liver was performed at different time intervals. Results: Peak liver enhancement was typically observed 10-30 min after administration and the enhancement declined with a half-time of about 5 h. This pattern was observed in all sequences (SE 400/15, FLASH, and SE 132/10), with both doses and with both rates of administration. The peak enhancement was greater, though not significantly so after 20 μmol/kg than after 10 μmol/kg. A higher relative peak signal was observed with SE 132/10 than with FLASH or SE 400/15. (orig./AJ)

  20. Optimizing computed tomography pulmonary angiography using right atrium bolus monitoring combined with spontaneous respiration

    Energy Technology Data Exchange (ETDEWEB)

    Min, Wang; Jian, Li; Rui, Zhai [Jining No. 1 People' s Hospital, Department of Computed Tomography, Jining City, ShanDong Province (China); Wen, Li [Jining No. 1 People' s Hospital, Department of Gastroenterology, Jining, ShanDong (China); Dai, Lun-Hou [Shandong Chest Hospital, Department of Radiology, Jinan, ShanDong (China)

    2015-09-15

    CT pulmonary angiography (CTPA) aims to provide pulmonary arterial opacification in the absence of significant pulmonary venous filling. This requires accurate timing of the imaging acquisition to ensure synchronization with the peak pulmonary artery contrast concentration. This study was designed to test the utility of right atrium (RA) monitoring in ensuring optimal timing of CTPA acquisition. Sixty patients referred for CTPA were divided into two groups. Group A (n = 30): CTPA was performed using bolus triggering from the pulmonary trunk, suspended respiration and 70 ml of contrast agent (CA). Group B (n = 30): CTPA image acquisition was triggered using RA monitoring with spontaneous respiration and 40 ml of CA. Image quality was compared. Subjective image quality, average CT values of pulmonary arteries and density difference between artery and vein pairs were significantly higher whereas CT values of pulmonary veins were significantly lower in group B (all P < 0.05). There was no significant difference between the groups in the proportion of subjects where sixth grade pulmonary arteries were opacified (P > 0.05). RA monitoring combined with spontaneous respiration to trigger image acquisition in CTPA produces optimal contrast enhancement in pulmonary arterial structures with minimal venous filling even with reduced doses of CA. (orig.)

  1. Bolus versus continuous low dose of enalaprilat in congestive heart failure with acute refractory decompensation.

    Science.gov (United States)

    Podbregar, M; Voga, G; Horvat, M; Zuran, I; Krivec, B; Skale, R; Pareznik, R

    1999-01-01

    The first dose of angiotensin-converting enzyme (ACE) inhibitors may trigger a considerable fall of blood pressure in chronic heart failure. The response may be dose-related. To determine hemodynamic and systemic oxygenation effects of low-dose enalaprilat, we administered intravenous enalaprilat (0.004 mg/kg) as bolus (group B) or continuous 1-hour infusion (group C) in 20 patients with congestive heart failure due to ischemic heart disease with acute decompensation refractory to inotropic, vasodilator and diuretic therapy. Hemodynamic and systemic oxygenation variables were recorded at baseline (+0 min), +30, +60, +120, +180, and +360 min after the start of intervention. Mean arterial pressure (MAP) (p < 0. 001), mean pulmonary artery pressure (MPAP) (p < 0.001), pulmonary artery occlusion pressure (PAOP) (p < 0.001), oxygen extraction ratio (ER) (p < 0.026) decreased regardless of enalaprilat application. Compared to group B, there was in group C prolonged decrease of MAP, MPAP, PAOP, ER and increase of pulmonary artery oxyhemoglobin saturation in regard to baseline values. Cardiac index, heart rate, central venous pressure and oxygen consumption index did not change. A low dose of intravenous enalaprilat (0.004 mg/kg) can be used to safely improve hemodynamics and systemic oxygenation in congestive heart failure due to ischemic heart disease with acute refractory decompensation.

  2. Thoracic pathologies on scout views and bolus tracking slices for computed tomographic cerebral angiography

    Energy Technology Data Exchange (ETDEWEB)

    Groth, M.; Fiehler, J.; Buhk, J.H. [University Medical Center Hamburg-Eppendorf (Germany). Dept. of Diagnostic and Interventional Neuroradiology; Henes, F.O. [University Medical Center Hamburg-Eppendorf (Germany). Dept. of Diagnostic and Interventional Radiology

    2015-08-15

    To evaluate the incidence of additional thoracic pathologic findings (TPF) detected on scout views and corresponding bolus tracking slices (SVBT) for computed tomographic cerebral angiography (CTCA) and to test the reliability and accuracy of these findings. The study collective included 505 consecutive patients who underwent multidetector CTCA. Appendant SVBT of all patients were reviewed for any pathologic findings and patient medical reports were analyzed, if any medical treatment was initiated for the detected pathologic findings. In 18 patients thoracic CT scans were performed in the same session. These were additionally reviewed by two blinded observers to test for intra- and interobserver reliability as well as for accuracy of detecting thoracic pathologies on SVBT. TPF were detected in 165 (33 %) SVBT. The five most common pathologic findings were: pleural effusion, 12 %; pneumonia, 8 %; atelectasis/dystelecatsis, 6 %; pericardial effusion, 2 % and elevated diaphragm, 1 %. For 48 % of these findings medical treatment was initiated. SVBT showed a sensitivity of 53 %, a specificity of 99 %, a positive predictive value of 89 %, a negative predictive value of 94 % and accuracy of 94 % for the detection of TPF. The intraobserver reliability was very good and the interobserver reliability showed moderate agreement. SVBT for CTCA should be reviewed with care by radiologists, since additional TPF can affect patient management. Nevertheless, despite a high specificity of SVBT for detecting TPF, an only moderate sensitivity has to be taken into account.

  3. Effects of advanced carbohydrate counting guided by an automated bolus calculator in Type 1 diabetes mellitus (StenoABC)

    DEFF Research Database (Denmark)

    Hommel, E; Schmidt, S; Vistisen, D

    2017-01-01

    -centre, investigator-initiated clinical study. We enrolled advanced carbohydrate counting-naïve adults with Type 1 diabetes and HbA1c levels 64-100 mmol/mol (8.0-11.3%), who were receiving multiple daily insulin injection therapy. In a 1:1-ratio, participants were randomized to receive training in either advanced......AIMS: To test whether concomitant use of an automated bolus calculator for people with Type 1 diabetes carrying out advanced carbohydrate counting would induce further improvements in metabolic control. METHODS: We conducted a 12-month, randomized, parallel-group, open-label, single...... carbohydrate counting using mental calculations (MC group) or advanced carbohydrate counting using an automated bolus calculator (ABC group) during a 3.5-h group training course. For 12 months after training, participants attended a specialized diabetes centre quarterly. The primary outcome was change in HbA1c...

  4. Development of a bolus injection system for regional deposition studies of nanoparticles in the human respiratory system

    International Nuclear Information System (INIS)

    Koujalagi, V; Semple, S; Ayres, J G; Ramesh, S L; Gunarathne, G P P

    2009-01-01

    This study presents the work carried out in developing a precision bolus injection system in order to understand the regional deposition of nanoparticles (NP) in human lung. A real-time control system has been developed that is capable of storing graphite NP, assessing human breathing pattern and delivering a bolus of the stored NP at a pre-determined instance of the inhalation phase of breathing. This will form the basis for further development of a system to deliver radioactive nanoparticles to enable 3-dimensional lung imaging using techniques such as positron emission tomography (PET). The system may then be used to better understand the actual regional deposition in human lung, which could validate or challenge the current computational lung models such as that published by the International Commission for Radiation Protection (ICRP-1994). A dose related response to inhaled PM can possibly be shown, which can be used to review the current workplace exposure limits (WELs).

  5. Development of a bolus injection system for regional deposition studies of nanoparticles in the human respiratory system

    Science.gov (United States)

    Koujalagi, V.; Ramesh, S. L.; Gunarathne, G. P. P.; Semple, S.; Ayres, J. G.

    2009-02-01

    This study presents the work carried out in developing a precision bolus injection system in order to understand the regional deposition of nanoparticles (NP) in human lung. A real-time control system has been developed that is capable of storing graphite NP, assessing human breathing pattern and delivering a bolus of the stored NP at a pre-determined instance of the inhalation phase of breathing. This will form the basis for further development of a system to deliver radioactive nanoparticles to enable 3-dimensional lung imaging using techniques such as positron emission tomography (PET). The system may then be used to better understand the actual regional deposition in human lung, which could validate or challenge the current computational lung models such as that published by the International Commission for Radiation Protection (ICRP-1994). A dose related response to inhaled PM can possibly be shown, which can be used to review the current workplace exposure limits (WELs).

  6. Doxorubicin: Comparison between 3-h continuous and bolus intravenous administration paradigms on cardio-renal axis, mitochondrial sphingolipids and pathology

    International Nuclear Information System (INIS)

    Kamendi, Harriet; Zhou, Ying; Crosby, Meredith; Keirstead, Natalie; Snow, Debra; Bentley, Patricia; Patel, Nilaben; Barthlow, Herbert; Luo, Wenli; Dragan, Yvonne; Bialecki, Russell

    2015-01-01

    Doxorubicin (DOX) is a potent and effective broad-spectrum anthracycline antitumor agent, but its clinical usefulness is restricted by cardiotoxicity. This study compared pharmacokinetic, functional, structural and biochemical effects of single dose DOX bolus or 3-h continuous iv infusion (3-h iv) in the Han–Wistar rat to characterize possible treatment-related differences in drug safety over a 72 h observation period. Both DOX dosing paradigms significantly altered blood pressure, core body temperature and QA interval (indirect measure of cardiac contractility); however, there was no recovery observed in the bolus iv treatment group. Following the 3-h iv treatment, blood pressures and QA interval normalized by 36 h then rose above baseline levels over 72 h. Both treatments induced biphasic changes in heart rate with initial increases followed by sustained decreases. Cardiac injury biomarkers in plasma were elevated only in the bolus iv treatment group. Tissue cardiac injury biomarkers, cardiac mitochondrial complexes I, III and V and cardiac mitochondrial sphingolipids were decreased only in the bolus iv treatment group. Results indicate that each DOX dosing paradigm deregulates sinus rhythm. However, slowing the rate of infusion allows for functional compensation of blood pressure and may decrease the likelihood of cardiac myocyte necrosis via a mechanism associated with reduced mitochondrial damage. - Highlights: • Despite damaging cardiomyocytes, continuous iv doxorubicin improves cardiovascular outcomes. • This study supports administration of doxorubicin via slow continuous iv infusion limits acute cardio-toxicity. • This study supports use of metabolomic-derived lipid biomarkers for improved quantification of cardiovascular risk. • This study supports systems-based physiological approach to generate a data that can greatly inform risk assessments.

  7. Optimized enhancement in helical CT: Experiences with a real-time bolus tracking system in 628 patients

    International Nuclear Information System (INIS)

    Kirchner, J.; Kickuth, R.; Laufer, U.; Noack, M.; Liermann, D.

    2000-01-01

    AIMS: Ultrafast detector technology enables bolus-triggered application of contrast media. In a prospective study we investigated the benefit of this new method with the intention of optimizing enhancement during examination of the chest and abdomen. MATERIALS AND METHODS: In total, we examined 548 patients under standardized conditions. All examinations were performed on a Somatom Plus 4 Power CT system (Siemens Corp., Forchheim, Germany) using the CARE-Bolus software. This produces repetitive low-dose test images (e.g. for the lung: 140 kV, 43 mA, TI 0.5 s) and measures the Hounsfield attenuation in a pre-selected region of interest. After exceeding a defined threshold, a diagnostic spiral CT examination was begun automatically. The data obtained from 321 abdominal CT and 179 lung CT examinations were correlated with different parameters such as age, weight and height of the patients and parameters of vascular access. In a group of 80 patients, the injection of contrast medium was stopped after reaching a pre-defined threshold of an increase of 100 HU over the baseline. Then, we assessed the maximal enhancement of liver, pulmonal artery trunk and aortic arch. RESULTS: There was no correlation between bolus geometry and age, body surface or weight. In helical CT of the abdomen the threshold was reached after a mean trigger time of 27 s (range 13-67 s) and only 65 ml (range 41-105 ml) of contrast medium were administered. In helical CT of the lung the threshold was reached after 21 s (range 12-48 s) and the mean amount of administered contrast medium was 48 ml (range 38-71 ml). CONCLUSION: Bolus triggering allows optimized enhancement of the organs and reduces the dose of contrast material required compared with standard administration. Kirchner, J. (2000). Clinical Radiology 55, 368-373

  8. Optimized enhancement in helical CT: experiences with a real-time bolus tracking system in 628 patients.

    Science.gov (United States)

    Kirchner, J; Kickuth, R; Laufer, U; Noack, M; Liermann, D

    2000-05-01

    Ultrafast detector technology enables bolus-triggered application of contrast media. In a prospective study we investigated the benefit of this new method with the intention of optimizing enhancement during examination of the chest and abdomen. In total, we examined 548 patients under standardized conditions. All examinations were performed on a Somatom Plus 4 Power CT system (Siemens Corp., Forchheim, Germany) using the CARE-Bolus software. This produces repetitive low-dose test images (e.g. for the lung: 140 kV, 43 mA, TI 0.5 s) and measures the Hounsfield attenuation in a pre-selected region of interest. After exceeding a defined threshold, a diagnostic spiral CT examination was begun automatically. The data obtained from 321 abdominal CT and 179 lung CT examinations were correlated with different parameters such as age, weight and height of the patients and parameters of vascular access. In a group of 80 patients, the injection of contrast medium was stopped after reaching a pre-defined threshold of an increase of 100 HU over the baseline. Then, we assessed the maximal enhancement of liver, pulmonal artery trunk and aortic arch. There was no correlation between bolus geometry and age, body surface or weight. In helical CT of the abdomen the threshold was reached after a mean trigger time of 27 s (range 13-67 s) and only 65 ml (range 41-105 ml) of contrast medium were administered. In helical CT of the lung the threshold was reached after 21 s (range 12-48 s) and the mean amount of administered contrast medium was 48 ml (range 38-71 ml). Bolus triggering allows optimized enhancement of the organs and reduces the dose of contrast material required compared with standard administration. Copyright 2000 The Royal College of Radiologists.

  9. Feasibility of test-bolus DCE-MRI using CAIPIRINHA-VIBE for the evaluation of pancreatic malignancies

    Energy Technology Data Exchange (ETDEWEB)

    Huh, Jimi; Seo, Nieun; Kim, Bohyun [University of Ulsan College of Medicine, Department of Radiology and Research Institute of Radiology, Asan Medical Center, 88 Olympic-ro 43-gil, Songpa-gu, Seoul (Korea, Republic of); Choi, Yoonseok; Woo, Dong-Cheol; Lee, Chang Kyung [Asan Medical Center, Bioimaging Center, Asan Institute for Life Sciences, Seoul (Korea, Republic of); Kim, In Seong [Siemens Healthcare, Seoul (Korea, Republic of); Nickel, Dominik [Siemens Healthcare, Erlangen (Germany); Kim, Kyung Won [University of Ulsan College of Medicine, Department of Radiology and Research Institute of Radiology, Asan Medical Center, 88 Olympic-ro 43-gil, Songpa-gu, Seoul (Korea, Republic of); Asan Medical Center, Bioimaging Center, Asan Institute for Life Sciences, Seoul (Korea, Republic of)

    2016-11-15

    To evaluate the feasibility of test-bolus dynamic contrast-enhanced (DCE) MRI with CAIPIRINHA-VIBE for pancreatic malignancies. Thirty-two patients underwent DCE-MRI with CAIPIRINHA-VIBE after injection of 2 mL gadolinium. From the resulting time-intensity curve (TIC), we estimated the arterial (AP) and portal venous phase (PVP) scan timing for subsequent multiphasic MRI. DCE-MRI perfusion maps were generated, and perfusion parameters were calculated. The image quality was rated on a 5-point scale (1: poor, 5: excellent). Goodness-of-fit of the TIC was evaluated by Pearson's χ{sup 2} test. Test-bolus DCE-MRIs with high temporal (3 s) and spatial resolution (1 x 1 x 4 mm{sup 3}) were acquired with good-quality perfusion maps of Ktrans and iAUC (mean score 4.313 ± 0.535 and 4.125 ± 0.554, respectively). The mean χ{sup 2} values for fitted TICs were 0.115 ± 0.082 for the pancreatic parenchyma and 0.784 ± 0.074 for pancreatic malignancies, indicating an acceptable goodness-of-fit. Test-bolus DCE-MRI was highly accurate in estimating the proper timing of AP (90.6 %) and PVP (100 %) of subsequent multiphasic MRI. Between pancreatic adenocarcinomas and neuroendocrine tumours, there were significant differences in the Ktrans (0.073 ± 0.058 vs. 0.308 ± 0.062, respectively; p = 0.007) and iAUC (1.501 ± 0.828 vs. 3.378 ± 0.378, respectively; p = 0.045). Test-bolus DCE-MRI using CAIPIRINHA-VIBE is feasible for incorporating perfusion analysis of pancreatic tumours into routine multiphasic MRI. (orig.)

  10. Three-dimensional printer-aided casting of soft, custom silicone boluses (SCSBs) for head and neck radiation therapy.

    Science.gov (United States)

    Chiu, Tsuicheng; Tan, Jun; Brenner, Mathew; Gu, Xuejun; Yang, Ming; Westover, Kenneth; Strom, Tobin; Sher, David; Jiang, Steve; Zhao, Bo

    Custom tissue compensators provide dosimetric advantages for treating superficial or complex anatomy, but currently available fabrication technology is expensive or impractical for most clinical operations and yields compensators that are difficult for patients to tolerate. We aimed to develop an inexpensive, clinically feasible workflow for generating patient-specific, soft, custom silicone boluses (SCSBs) for head-and-neck (HN) radiation therapy. We developed a method using 3-dimensional printed parts for generating SCSBs for the treatment of HN cancers. The clinical workflow for generation of SCSBs was characterized inclusive of patient simulation to treatment in terms of resource time and cost. Dosimetric properties such as percentage depth dose and dose profiles were measured for SCSBs using GaF films. Comprehensive measurements were also conducted on an HN phantom. SCSBs were generated and used for electron or photon based radiation treatments of 7 HN patients with lesions at nose, cheek, eye, or ears. In vivo dose measurements with optically simulated luminescence dosimeters were performed. Total design and fabrication time from patient simulation to radiation treatment start required approximately 1 week, with fabrication constituting 1 to 2 working days depending on bolus surface area, volume, and complexity. Computed tomography and dosimetric properties of the soft bolus were similar to water. In vivo dose measurements on 7 treated patients confirmed that the dose deposition conformed to planned doses. Material costs were lower than currently available hard plastic boluses generated with 3-dimensional printing technology. All treated patients tolerated SCSBs for the duration of therapy. Generation and use of SCSBs for clinical use is feasible and effective for the treatment of HN cancers. Copyright © 2017 American Society for Radiation Oncology. Published by Elsevier Inc. All rights reserved.

  11. Doxorubicin: Comparison between 3-h continuous and bolus intravenous administration paradigms on cardio-renal axis, mitochondrial sphingolipids and pathology

    Energy Technology Data Exchange (ETDEWEB)

    Kamendi, Harriet, E-mail: harriet_kamendi@kandih.com [Drug Safety and Metabolism, AstraZeneca, Waltham, MA 02451 (United States); Zhou, Ying, E-mail: yingzhou526@gmail.com [Oncology Innovative Medicines and Early Development, AstraZeneca, Waltham, MA 02451 (United States); Crosby, Meredith, E-mail: Meredith.crosby@astrazeneca.com [Drug Safety and Metabolism, AstraZeneca, Waltham, MA 02451 (United States); Keirstead, Natalie, E-mail: Nkeirstead@alnylam.com [Drug Safety and Metabolism, AstraZeneca, Waltham, MA 02451 (United States); Snow, Debra, E-mail: Debra.snow@astrazeneca.com [Drug Safety and Metabolism, AstraZeneca, Waltham, MA 02451 (United States); Bentley, Patricia, E-mail: patricia.bentley@abbvie.com [Drug Safety and Metabolism, AstraZeneca, Waltham, MA 02451 (United States); Patel, Nilaben, E-mail: patelnilaben@yahoo.com [Drug Safety and Metabolism, AstraZeneca, Waltham, MA 02451 (United States); Barthlow, Herbert, E-mail: Herbert.barthlow@astrazeneca.com [Drug Safety and Metabolism, AstraZeneca, Waltham, MA 02451 (United States); Luo, Wenli, E-mail: Wenli.luo@astrazeneca.com [Discovery Sciences, Innovative Medicines, AstraZeneca, Waltham, MA 02451 (United States); Dragan, Yvonne, E-mail: Yvonne.P.Dragan@takeda.com [Drug Safety and Metabolism, AstraZeneca, Waltham, MA 02451 (United States); Bialecki, Russell, E-mail: russell.bialecki@astrazeneca.com [Drug Safety and Metabolism, AstraZeneca, Waltham, MA 02451 (United States)

    2015-12-15

    Doxorubicin (DOX) is a potent and effective broad-spectrum anthracycline antitumor agent, but its clinical usefulness is restricted by cardiotoxicity. This study compared pharmacokinetic, functional, structural and biochemical effects of single dose DOX bolus or 3-h continuous iv infusion (3-h iv) in the Han–Wistar rat to characterize possible treatment-related differences in drug safety over a 72 h observation period. Both DOX dosing paradigms significantly altered blood pressure, core body temperature and QA interval (indirect measure of cardiac contractility); however, there was no recovery observed in the bolus iv treatment group. Following the 3-h iv treatment, blood pressures and QA interval normalized by 36 h then rose above baseline levels over 72 h. Both treatments induced biphasic changes in heart rate with initial increases followed by sustained decreases. Cardiac injury biomarkers in plasma were elevated only in the bolus iv treatment group. Tissue cardiac injury biomarkers, cardiac mitochondrial complexes I, III and V and cardiac mitochondrial sphingolipids were decreased only in the bolus iv treatment group. Results indicate that each DOX dosing paradigm deregulates sinus rhythm. However, slowing the rate of infusion allows for functional compensation of blood pressure and may decrease the likelihood of cardiac myocyte necrosis via a mechanism associated with reduced mitochondrial damage. - Highlights: • Despite damaging cardiomyocytes, continuous iv doxorubicin improves cardiovascular outcomes. • This study supports administration of doxorubicin via slow continuous iv infusion limits acute cardio-toxicity. • This study supports use of metabolomic-derived lipid biomarkers for improved quantification of cardiovascular risk. • This study supports systems-based physiological approach to generate a data that can greatly inform risk assessments.

  12. The 2011 Periastron Passage of the Be Binary δ Scorpii

    Science.gov (United States)

    Miroshnichenko, A. S.; Pasechnik, A. V.; Manset, N.; Carciofi, A. C.; Rivinius, Th.; Štefl, S.; Gvaramadze, V. V.; Ribeiro, J.; Fernando, A.; Garrel, T.; Knapen, J. H.; Buil, C.; Heathcote, B.; Pollmann, E.; Mauclaire, B.; Thizy, O.; Martin, J.; Zharikov, S. V.; Okazaki, A. T.; Gandet, T. L.; Eversberg, T.; Reinecke, N.

    2013-04-01

    We describe the results of the world-wide observing campaign of the highly eccentric Be binary system δ Scorpii 2011 periastron passage which involved professional and amateur astronomers. Our spectroscopic observations provided a precise measurement of the system orbital period at 10.8092 ± 0.0005 yr. Fitting of the He II 4686 Å line radial velocity curve determined the periastron passage time on 2011 July 3, UT 9:20 with a 0.9-day uncertainty. Both these results are in a very good agreement with recent findings from interferometry. We also derived new evolutionary masses of the binary components (13 and 8.2 M ⊙) and a new distance of 136 pc from the Sun, consistent with the HIPPARCOS parallax. The radial velocity and profile variations observed in the Hα line near the 2011 periastron reflected the interaction of the secondary component and the circumstellar disk around the primary component. Using these data, we estimated a disk radius of 150 R ⊙. Our analysis of the radial velocity variations measured during the periastron passage time in 2000 and 2011 along with those measured during the 20th century, the high eccentricity of the system, and the presence of a bow shock-like structure around it suggest that δ Sco might be a runaway triple system. The third component should be external to the known binary and move on an elliptical orbit that is tilted by at least 40° with respect to the binary orbital plane for such a system to be stable and responsible for the observed long-term radial velocity variations. This paper is partially based on observations obtained at the Canada-France-Hawaii Telescope (CFHT) which is operated by the National Research Council of Canada, the Institut National des Sciences de l'Univers of the Centre National de la Recherche Scientifique de France, and the University of Hawaii, the 2.2 m MPG telescope operated at ESO/La Silla under program IDs 086.A-9019 and 087.A-9005, the IAC80 telescope in the Spanish Observatorio del Teide

  13. Pathological bolus exposure may define gastro-esophageal reflux better than pathological acid exposure in patients with globus.

    Science.gov (United States)

    Sinn, Dong Hyun; Kim, Beom Jin; Son, Hee Jung; Kim, Jae J; Rhee, Jong Chul; Rhee, Poong-Lyul

    2012-01-01

    Conventionally, pathological acid exposure (PAE), defined by acid reflux only, is used to identify gastro-esophageal reflux disease (GERD). However, weak acid reflux or non-acid reflux also induces reflux symptoms. Defining abnormal reflux based on all reflux episodes may better identify GERD and would be more useful among patients with atypical GERD symptoms, such as globus. Impedance-pHmetry results of 31 globus patients, off acid suppressants, were analysed. A median of 24 episodes of reflux were observed. Of the reflux episodes, 54% were non-acid reflux and 50% reached the proximal extent. PAE was observed in 6 patients (19%). For 5 patients (16%) without PAE, there was evidence of increased bolus exposure compared to normal controls (an intraesophageal bolus exposure for more than 1.4% of the recording time, defined as pathological bolus exposure, PBE). When GERD was defined by PAE or esophagitis, the prevalence of GERD was 29%. When GERD was defined by PBE, PAE or esophagitis, the prevalence was 42%. PBE identified 13% of the patients who otherwise would have been missed. A significant proportion of patients without PAE had evidence of PBE. PBE may be a more useful definition for identifying patients with abnormal increase in reflux in patients with globus. Further studies are warranted.

  14. Test-retest reproducibility of the metabotropic glutamate receptor 5 ligand [{sup 18}F]FPEB with bolus plus constant infusion in humans

    Energy Technology Data Exchange (ETDEWEB)

    Park, Eunkyung; Sullivan, Jenna M.; Planeta, Beata; Gallezot, Jean-Dominique; Lim, Keunpoong; Lin, Shu-Fei; Ropchan, Jim; Huang, Yiyun; Carson, Richard E. [Yale School of Medicine, PET Center, Department of Diagnostic Radiology, 801 Howard Avenue, PO Box 208048, New Haven, CT (United States); McCarthy, Timothy J. [Pfizer Worldwide Research and Development, Cambridge, MA (United States); Ding, Yu-Shin [New York University School of Medicine, Department of Radiology, New York, NY (United States); Morris, Evan D.; Williams, Wendol A. [Yale School of Medicine, PET Center, Department of Diagnostic Radiology, 801 Howard Avenue, PO Box 208048, New Haven, CT (United States); Yale School of Medicine, Department of Psychiatry, New Haven, CT (United States)

    2015-09-15

    [{sup 18}F]FPEB is a promising PET radioligand for the metabotropic glutamate receptor 5 (mGluR5), a potential target for the treatment of neuropsychiatric diseases. The purpose of this study was to evaluate the test-retest reproducibility of [{sup 18}F]FPEB in the human brain. Seven healthy male subjects were scanned twice, 3 - 11 weeks apart. Dynamic data were acquired using bolus plus infusion of 162 ± 32 MBq [{sup 18}F]FPEB. Four methods were used to estimate volume of distribution (V{sub T}): equilibrium analysis (EQ) using arterial (EQ{sub A}) or venous input data (EQ{sub V}), MA1, and a two-tissue compartment model (2 T). Binding potential (BP{sub ND}) was also estimated using cerebellar white matter (CWM) or gray matter (CGM) as the reference region using EQ, 2 T and MA1. Absolute test-retest variability (aTRV) of V{sub T} and BP{sub ND} were calculated for each method. Venous blood measurements (C{sub V}) were compared with arterial input (C{sub A}) to examine their usability in EQ analysis. Regional V{sub T} estimated by the four methods displayed a high degree of agreement (r{sup 2} ranging from 0.83 to 0.99 among the methods), although EQ{sub A} and EQ{sub V} overestimated V{sub T} by a mean of 9 % and 7 %, respectively, compared to 2 T. Mean values of aTRV of V{sub T} were 11 % by EQ{sub A}, 12 % by EQ{sub V}, 14 % by MA1 and 14 % by 2 T. Regional BP{sub ND} also agreed well among the methods and mean aTRV of BP{sub ND} was 8 - 12 % (CWM) and 7 - 9 % (CGM). Venous and arterial blood concentrations of [{sup 18}F]FPEB were well matched during equilibrium (C{sub V} = 1.01 . C{sub A}, r{sup 2} = 0.95). [{sup 18}F]FPEB binding shows good TRV with minor differences among analysis methods. Venous blood can be used as an alternative for input function measurement instead of arterial blood in EQ analysis. Thus, [{sup 18}F]FPEB is an excellent PET imaging tracer for mGluR5 in humans. (orig.)

  15. Test-retest reproducibility of the metabotropic glutamate receptor 5 ligand [18F]FPEB with bolus plus constant infusion in humans

    International Nuclear Information System (INIS)

    Park, Eunkyung; Sullivan, Jenna M.; Planeta, Beata; Gallezot, Jean-Dominique; Lim, Keunpoong; Lin, Shu-Fei; Ropchan, Jim; Huang, Yiyun; Carson, Richard E.; McCarthy, Timothy J.; Ding, Yu-Shin; Morris, Evan D.; Williams, Wendol A.

    2015-01-01

    [ 18 F]FPEB is a promising PET radioligand for the metabotropic glutamate receptor 5 (mGluR5), a potential target for the treatment of neuropsychiatric diseases. The purpose of this study was to evaluate the test-retest reproducibility of [ 18 F]FPEB in the human brain. Seven healthy male subjects were scanned twice, 3 - 11 weeks apart. Dynamic data were acquired using bolus plus infusion of 162 ± 32 MBq [ 18 F]FPEB. Four methods were used to estimate volume of distribution (V T ): equilibrium analysis (EQ) using arterial (EQ A ) or venous input data (EQ V ), MA1, and a two-tissue compartment model (2 T). Binding potential (BP ND ) was also estimated using cerebellar white matter (CWM) or gray matter (CGM) as the reference region using EQ, 2 T and MA1. Absolute test-retest variability (aTRV) of V T and BP ND were calculated for each method. Venous blood measurements (C V ) were compared with arterial input (C A ) to examine their usability in EQ analysis. Regional V T estimated by the four methods displayed a high degree of agreement (r 2 ranging from 0.83 to 0.99 among the methods), although EQ A and EQ V overestimated V T by a mean of 9 % and 7 %, respectively, compared to 2 T. Mean values of aTRV of V T were 11 % by EQ A , 12 % by EQ V , 14 % by MA1 and 14 % by 2 T. Regional BP ND also agreed well among the methods and mean aTRV of BP ND was 8 - 12 % (CWM) and 7 - 9 % (CGM). Venous and arterial blood concentrations of [ 18 F]FPEB were well matched during equilibrium (C V = 1.01 . C A , r 2 = 0.95). [ 18 F]FPEB binding shows good TRV with minor differences among analysis methods. Venous blood can be used as an alternative for input function measurement instead of arterial blood in EQ analysis. Thus, [ 18 F]FPEB is an excellent PET imaging tracer for mGluR5 in humans. (orig.)

  16. Movement of Water Across Passages Connecting Philippine Inland Sea Basins

    Directory of Open Access Journals (Sweden)

    Lambert Anthony B Meñez

    2006-12-01

    Full Text Available Advection of Pacific water to the inland seas is through a number of straits bordering the archipelago. Movement of water was demonstrated by temperature-salinity diagrams plotted for a number of stations situated along the various passages. As water from the Pacific flowed through the straits its characteristic T-S profile was modified as it mixed with waters of different properties. This was best seen along the San Bernardino-Verde Island transect where strong surface flow during the NE monsoon resulted in separation of profiles at the surface indicating dilution as water moved away from the source. For deeper water, the erosion of the subsurface salinity minimum and maximum representing the core of the intermediate waters showed transport. These waters were restricted by shallow sill along the eastern coast of the country and limited to a depth of 441m by the sill across the Mindoro Strait.

  17. Disintegration of swift carbon clusters during passage through matter

    International Nuclear Information System (INIS)

    Koch, K.; Otteken, D.; Tuszynski, W.; Seidl, M.; Voit, H.

    2003-01-01

    Thin luminescent foils covered upstream with layers of Formvar or gold of various thicknesses were bombarded with C 8 clusters with energies between 5 and 10 MeV. The C 8 induced relative luminescence yield Φ 8 increases with growing layer thickness and approaches smoothly the value 8Φ 1 , i.e., the luminescence yield induced by eight well-separated C 1 cluster constituents. This is a clear demonstration of the gradual separation between the cluster constituents during the passage of the cluster through the layers. The layer thickness necessary to separate cluster constituents far enough to act as independent atomic ions with respect to the luminescence process was calculated. The result is that Formvar layers with a thickness of about 1150 nm or ≅250-nm-thick gold layers are necessary to establish this mutual independence of the cluster constituents. Both calculated values agree roughly with the layer thickness obtained from an extrapolation of the experimental data

  18. Adiabatic passage and ensemble control of quantum systems

    International Nuclear Information System (INIS)

    Leghtas, Z; Sarlette, A; Rouchon, P

    2011-01-01

    This paper considers population transfer between eigenstates of a finite quantum ladder controlled by a classical electric field. Using an appropriate change of variables, we show that this setting can be set in the framework of adiabatic passage, which is known to facilitate ensemble control of quantum systems. Building on this insight, we present a mathematical proof of robustness for a control protocol-chirped pulse-practised by experimentalists to drive an ensemble of quantum systems from the ground state to the most excited state. We then propose new adiabatic control protocols using a single chirped and amplitude-shaped pulse, to robustly perform any permutation of eigenstate populations, on an ensemble of systems with unknown coupling strengths. These adiabatic control protocols are illustrated by simulations on a four-level ladder.

  19. Spatial non-adiabatic passage using geometric phases

    Energy Technology Data Exchange (ETDEWEB)

    Benseny, Albert; Busch, Thomas [Okinawa Institute of Science and Technology Graduate University, Quantum Systems Unit, Okinawa (Japan); Kiely, Anthony; Ruschhaupt, Andreas [University College Cork, Department of Physics, Cork (Ireland); Zhang, Yongping [Okinawa Institute of Science and Technology Graduate University, Quantum Systems Unit, Okinawa (Japan); Shanghai University, Department of Physics, Shanghai (China)

    2017-12-15

    Quantum technologies based on adiabatic techniques can be highly effective, but often at the cost of being very slow. Here we introduce a set of experimentally realistic, non-adiabatic protocols for spatial state preparation, which yield the same fidelity as their adiabatic counterparts, but on fast timescales. In particular, we consider a charged particle in a system of three tunnel-coupled quantum wells, where the presence of a magnetic field can induce a geometric phase during the tunnelling processes. We show that this leads to the appearance of complex tunnelling amplitudes and allows for the implementation of spatial non-adiabatic passage. We demonstrate the ability of such a system to transport a particle between two different wells and to generate a delocalised superposition between the three traps with high fidelity in short times. (orig.)

  20. Comparison of Power Versus Manual Injection in Bolus Shape and Image Quality on Contrast-Enhanced Magnetic Resonance Angiography: An Experimental Study in a Swine Model.

    Science.gov (United States)

    Tsuboyama, Takahiro; Jost, Gregor; Pietsch, Hubertus; Tomiyama, Noriyuki

    2017-09-01

    The aim of this study was to compare power versus manual injection in bolus shape and image quality on contrast-enhanced magnetic resonance angiography (CE-MRA). Three types of CE-MRA (head-neck 3-dimensional [3D] MRA with a test-bolus technique, thoracic-abdominal 3D MRA with a bolus-tracking technique, and thoracic-abdominal time-resolved 4-dimensional [4D] MRA) were performed after power and manual injection of gadobutrol (0.1 mmol/kg) at 2 mL/s in 12 pigs (6 sets of power and manual injections for each type of CE-MRA). For the quantitative analysis, the signal-to-noise ratio was measured on ascending aorta, descending aorta, brachiocephalic trunk, common carotid artery, and external carotid artery on the 6 sets of head-neck 3D MRA, and on ascending aorta, descending aorta, brachiocephalic trunk, abdominal aorta, celiac trunk, and renal artery on the 6 sets of thoracic-abdominal 3D MRA. Bolus shapes were evaluated on the 6 sets each of test-bolus scans and 4D MRA. For the qualitative analysis, arterial enhancement, superimposition of nontargeted enhancement, and overall image quality were evaluated on 3D MRA. Visibility of bolus transition was assessed on 4D MRA. Intraindividual comparison between power and manual injection was made by paired t test, Wilcoxon rank sum test, and analysis of variance by ranks. Signal-to-noise ratio on 3D MRA was statistically higher with power injection than with manual injection (P < 0.001). Bolus shapes (test-bolus, 4D MRA) were represented by a characteristic standard bolus curve (sharp first-pass peak followed by a gentle recirculation peak) in all the 12 scans with power injection, but only in 1 of the 12 scans with manual injection. Standard deviations of time-to-peak enhancement were smaller in power injection than in manual injection. Qualitatively, although both injection methods achieved diagnostic quality on 3D MRA, power injection exhibited significantly higher image quality than manual injection (P = 0.001) due to

  1. Consequences of the Solar System passage through dense interstellar clouds

    Directory of Open Access Journals (Sweden)

    A. G. Yeghikyan

    2003-06-01

    Full Text Available Several consequences of the passage of the solar system through dense interstellar molecular clouds are discussed. These clouds, dense (more than 100 cm-3, cold (10–50 K and extended (larger than 1 pc, are characterized by a gas-to-dust mass ratio of about 100, by a specific power grain size spectrum (grain radii usually cover the range 0.001–3 micron and by an average dust-to-gas number density ratio of about 10-12. Frequently these clouds contain small-scale (10–100 AU condensations with gas concentrations ranging up to 10 5 cm-3. At their casual passage over the solar system they exert pressures very much enhanced with respect to today’s standards. Under these conditions it will occur that the Earth is exposed directly to the interstellar flow. It is shown first that even close to the Sun, at 1 AU, the cloud’s matter is only partly ionized and should mainly interact with the solar wind by charge exchange processes. Dust particles of the cloud serve as a source of neutrals, generated by the solar UV irradiation of dust grains, causing the evaporation of icy materials. The release of neutral atoms from dust grains is then followed by strong influences on the solar wind plasma flow. The behavior of the neutral gas inflow parameters is investigated by a 2-D hydrodynamic approach to model the interaction processes. Because of a reduction of the heliospheric dimension down to 1 AU, direct influence of the cloud’s matter to the terrestrial environment and atmosphere could be envisaged.Key words. Interplanetary physics (heliopause and solar wind termination; interplanetary dust; interstellar gas

  2. Consequences of the Solar System passage through dense interstellar clouds

    Directory of Open Access Journals (Sweden)

    A. G. Yeghikyan

    Full Text Available Several consequences of the passage of the solar system through dense interstellar molecular clouds are discussed. These clouds, dense (more than 100 cm-3, cold (10–50 K and extended (larger than 1 pc, are characterized by a gas-to-dust mass ratio of about 100, by a specific power grain size spectrum (grain radii usually cover the range 0.001–3 micron and by an average dust-to-gas number density ratio of about 10-12. Frequently these clouds contain small-scale (10–100 AU condensations with gas concentrations ranging up to 10 5 cm-3. At their casual passage over the solar system they exert pressures very much enhanced with respect to today’s standards. Under these conditions it will occur that the Earth is exposed directly to the interstellar flow. It is shown first that even close to the Sun, at 1 AU, the cloud’s matter is only partly ionized and should mainly interact with the solar wind by charge exchange processes. Dust particles of the cloud serve as a source of neutrals, generated by the solar UV irradiation of dust grains, causing the evaporation of icy materials. The release of neutral atoms from dust grains is then followed by strong influences on the solar wind plasma flow. The behavior of the neutral gas inflow parameters is investigated by a 2-D hydrodynamic approach to model the interaction processes. Because of a reduction of the heliospheric dimension down to 1 AU, direct influence of the cloud’s matter to the terrestrial environment and atmosphere could be envisaged.

    Key words. Interplanetary physics (heliopause and solar wind termination; interplanetary dust; interstellar gas

  3. The passage and initial implementation of Oregon's Measure 44

    Science.gov (United States)

    Goldman, L.; Glantz, S.

    1999-01-01

    OBJECTIVE—To prepare a history of the passage and early implementation of Ballot Measure 44, "An Act to Support the Oregon Health Plan", and tobacco control policymaking in Oregon. Measure 44 raised cigarette taxes in Oregon by US$0.30 per pack, and dedicated 10% of the revenues to tobacco control.
METHODS—Data were gathered from interviews with members of the Committee to Support the Oregon Health Plan, Measure 44's campaign committee, as well as with state and local officials, and tobacco control advocates. Additional information was obtained from public documents, internal memoranda, and news reports.
RESULTS—Although the tobacco industry outspent Measure 44's supporters 7 to 1, the initiative passed with 56% of the vote. Even before the election, tobacco control advocates were working to develop an implementation plan for the tobacco control programme. They mounted a successful lobbying campaign to see that the legislature did not divert tobacco control funds to other uses. They also stopped industry efforts to limit the scope of the programme. The one shortcoming of the tobacco control forces was not getting involved in planning the initiative early enough to influence the amount of money that was devoted to tobacco control. Although public health groups provided 37% of the money it cost to pass Measure 44, only 10% of revenues were devoted to tobacco control.
CONCLUSIONS—Proactive planning and aggressive implementation can secure passage of tobacco control initiatives and see that the associated implementing legislation follows good public health practice.


Keywords: advocacy; legislation; implementation; tobacco tax PMID:10599577

  4. Fish ladders: safe fish passage or hotspot for predation?

    Directory of Open Access Journals (Sweden)

    Angelo Antonio Agostinho

    Full Text Available Fish ladders are a strategy for conserving biodiversity, as they can provide connectivity between fragmented habitats and reduce predation on shoals that accumulate immediately below dams. Although the impact of predation downstream of reservoirs has been investigated, especially in juvenile salmonids during their downstream movements, nothing is known about predation on Neotropical fish in the attraction and containment areas commonly found in translocation facilities. This study analysed predation in a fish passage system at the Lajeado Dam on the Tocantins River in Brazil. The abundance, distribution, and the permanence (time spent of large predatory fish along the ladder, the injuries imposed by piranhas during passage and the presence of other vertebrate predators were investigated. From December 2002 to October 2003, sampling was conducted in four regions (downstream, along the ladder, in the forebay, and upstream of the reservoir using gillnets, cast nets and counts or visual observations. The captured fish were tagged with thread and beads, and any mutilations were registered. Fish, birds and dolphins were the main predator groups observed, with a predominance of the first two groups. The entrance to the ladder, in the downstream region, was the area with the highest number of large predators and was the only region with relevant non-fish vertebrates. The main predatory fish species were Rhaphiodon vulpinus, Hydrolycus armatus, and Serrasalmus rhombeus. Tagged individuals were detected predating along the ladder for up to 90 days. Mutilations caused by Serrasalmus attacks were noted in 36% of species and 4% of individuals at the top of the ladder. Our results suggested that the high density of fish in the restricted ladder environment, which is associated with injuries suffered along the ladder course and the presence of multiple predator groups with different predation strategies, transformed the fish corridor into a hotspot for

  5. TU-F-CAMPUS-I-01: Investigation of the Effective Dose From Bolus Tracking Acquisitions at Different Anatomical Locations in the Chest for CT

    Energy Technology Data Exchange (ETDEWEB)

    Nowik, P; Bujila, R; Merzan, D [Dept. of Medical Physics, Karolinska University Hospital, Stockholm (Sweden)

    2015-06-15

    Purpose: Stationary table acquisitions (Bolus tracking) in X-ray Computed Tomography (CT) can Result in dose length products (DLP) comparable to spiral scans. It is today unclear whether or not the effective dose (E) for Bolus Tracking can be approximated using target region specific conversion factors (E/DLP). The purpose of this study was to investigate how E depends on the anatomical location of the Bolus Tracking in relation to Chest CT scans with the same DLP. Methods: Effective doses were approximated for the ICRP 110 adult Reference Male (AM) and adult Reference Female (FM) computational voxel phantoms using software for CT dose approximations (pre-simulated MC data). The effective dose was first approximated for a Chest CT scan using spiral technique and a CTDIvol (32 cm) of 6 mGy. The effective dose from the spiral scan was then compared to E approximated for contiguous Bolus Tracking acquisitions (1 cm separation), with a total collimation of 1 cm, over different locations of the chest of the voxel phantoms. The number of rotations used for the Bolus Tracking acquisitions was adjusted to yield the same DLP (32 cm) as the spiral scan. Results: Depending on the anatomical location of the Bolus Tracking, E ranged by factors of 1.3 to 6.8 for the AM phantom and 1.4 to 3.3 for the AF phantom, compared to the effective dose of the spiral scans. The greatest E for the Bolus Tracking acquisitions was observed for anatomical locations coinciding with breast tissue. This can be expected as breast tissue has a high tissue weighting factor in the calculation of E. Conclusion: For Chest CT scans, the effective dose from Bolus Tracking is highly dependent on the anatomical location where the scan is administered and will not always accurately be represented using target region specific conversion factors.

  6. TMI cable tracer operation and maintenance manual for assembly 417910

    International Nuclear Information System (INIS)

    Sumstine, R.L.

    1983-11-01

    This manual provides technical information and instructions to operate and maintain the cable tracer designed for the Three Mile Island (TMI) Unit 2 Reactor Building. The TMI cable tracer was developed to allow TMI personnel to trace cables in cable trays that may be tested or sectioned for destructive examination

  7. Methane emission quantification from landfills using a double tracer approach

    DEFF Research Database (Denmark)

    Scheutz, Charlotte; Samuelsson, J.; Fredenslund, Anders Michael

    2007-01-01

    A tracer method was successfully used for quantification of the whole methane (CH4) emission from Fakse landfill. By using two different tracers the emission from different sections of the landfill could be quantified. Furthermore, is was possible to determine the emissions from local on site...

  8. Extended passaging increases the efficiency of neural differentiation from induced pluripotent stem cells

    Directory of Open Access Journals (Sweden)

    Koehler Karl R

    2011-08-01

    Full Text Available Abstract Background The use of induced pluripotent stem cells (iPSCs for the functional replacement of damaged neurons and in vitro disease modeling is of great clinical relevance. Unfortunately, the capacity of iPSC lines to differentiate into neurons is highly variable, prompting the need for a reliable means of assessing the differentiation capacity of newly derived iPSC cell lines. Extended passaging is emerging as a method of ensuring faithful reprogramming. We adapted an established and efficient embryonic stem cell (ESC neural induction protocol to test whether iPSCs (1 have the competence to give rise to functional neurons with similar efficiency as ESCs and (2 whether the extent of neural differentiation could be altered or enhanced by increased passaging. Results Our gene expression and morphological analyses revealed that neural conversion was temporally delayed in iPSC lines and some iPSC lines did not properly form embryoid bodies during the first stage of differentiation. Notably, these deficits were corrected by continual passaging in an iPSC clone. iPSCs with greater than 20 passages (late-passage iPSCs expressed higher expression levels of pluripotency markers and formed larger embryoid bodies than iPSCs with fewer than 10 passages (early-passage iPSCs. Moreover, late-passage iPSCs started to express neural marker genes sooner than early-passage iPSCs after the initiation of neural induction. Furthermore, late-passage iPSC-derived neurons exhibited notably greater excitability and larger voltage-gated currents than early-passage iPSC-derived neurons, although these cells were morphologically indistinguishable. Conclusions These findings strongly suggest that the efficiency neuronal conversion depends on the complete reprogramming of iPSCs via extensive passaging.

  9. Compliance Monitoring of Subyearling Chinook Salmon Smolt Survival and Passage at Bonneville Dam, Summer 2012

    Energy Technology Data Exchange (ETDEWEB)

    Skalski, J. R.; Townsend, Richard L.; Seaburg, Adam; Ploskey, Gene R.; Weiland, Mark A.; Hughes, James S.; Woodley, Christa M.; Deng, Zhiqun; Carlson, Thomas J.

    2013-05-01

    The purpose of this compliance study was to estimate dam passage survival of subyearling Chinook salmon at Bonneville Dam during summer 2012, as required by the 2008 Federal Columbia River Power System Biological Opinion. The study also estimated smolt passage survival from the forebay 2 km upstream of the dam to the tailrace 1 km below the dam, as well as forebay residence time, tailrace egress, and spill passage efficiency, as required in the 2008 Columbia Basin Fish Accords.

  10. On correlations between certain random variables associated with first passage Brownian motion

    International Nuclear Information System (INIS)

    Kearney, Michael J; Pye, Andrew J; Martin, Richard J

    2014-01-01

    We analyse how the area swept out by a Brownian motion up to its first passage time correlates with the first passage time itself, obtaining several exact results in the process. Additionally, we analyse the relationship between the time average of a Brownian motion during a first passage and the maximum value attained. The results, which find various applications, are in excellent agreement with simulations. (paper)

  11. Intravenous Bolus versus Continuous Infusion of Famotidine or Ranitidine on 24 H Intragastric Acidity in Fasting Healthy Volunteers

    Directory of Open Access Journals (Sweden)

    ABR Thomson

    1995-01-01

    Full Text Available Infusions of H2-receptor antagonists may be clinically indicated to maintain intragastric pH above 4 to reduce acute gastric mucosal lesions or to treat patients with bleeding peptic ulcers. Eight fasting healthy volunteers were randomly assigned to receive ranitidine infusion alone (150 mg/day, ranitidine infusion plus 50 mg bolus injection of ranitidine (total of 200 mg/day, famotidine infusion alone (40 mg/day or famotidine infusion plus 40 mg bolus injection of famotidine (total of 80 mg/day. Gastric fluid contents were aspirated for 24 h and collected as half-hourly samples in which pH measurements were made. Measures analyzed were mean and median pH, percentage pH at or below 3, 4 or 5 for the 24 h period, daytime, evening and nighttime. The data for each of the variables were analyzed as a Latin square crossover design of variance therapy; base pH before treatment administration in each crossover phase was employed as the covariant. Significant differential treatment means were tested by Newman-Keul’s multiple range test at the 5% level of significance. The mean and median evening pH were higher after famotidine than after ranitidine infusion, but all other pH readings were similar when using these doses. The addition of an initial loading bolus of 50 mg ranitidine to the ranitidine infusion did not result in any added differences in pH, whereas the addition of an initial loading bolus of 40 mg famotidine to the famotidine infusion resulted in a higher 24 h median pH, as well as a lower percentage of pH values of 4 or below, 16.6% versus 28.5%, P<0.05. However, the loading doses of ranitidine and famotidine were not equivalent in potency, and studies are needed to compare the potency of equivalent doses of ranitidine and famotidine when given by bolus plus infusion. Also the clinical relevance of these findings needs to be explored further in the type of individuals potentially requiring intravenous H2-receptor antagonists.

  12. Open-loop glucose control: Automatic IOB-based super-bolus feature for commercial insulin pumps.

    Science.gov (United States)

    Rosales, Nicolás; De Battista, Hernán; Vehí, Josep; Garelli, Fabricio

    2018-06-01

    Although there has been significant progress towards closed-loop type 1 diabetes mellitus (T1DM) treatments, most diabetic patients still treat this metabolic disorder in an open-loop manner, based on insulin pump therapy (basal and bolus insulin infusion). This paper presents a method for automatic insulin bolus shaping based on insulin-on-board (IOB) as an alternative to conventional bolus dosing. The methodology presented allows the pump to generate the so-called super-bolus (SB) employing a two-compartment IOB dynamic model. The extra amount of insulin to boost the bolus and the basal cutoff time are computed using the duration of insulin action (DIA). In this way, the pump automatically re-establishes basal insulin when IOB reaches its basal level. Thus, detrimental transients caused by manual or a-priori computations are avoided. The potential of this method is illustrated via in-silico trials over a 30 patients cohort in single meal and single day scenarios. In the first ones, improvements were found (standard treatment vs. automatic SB) both in percentage time in euglycemia (75g meal: 81.9 ± 15.59 vs. 89.51 ± 11.95, ρ ≃ 0; 100g meal: 75.12 ± 18.23 vs. 85.46 ± 14.96, ρ ≃ 0) and time in hypoglecymia (75g meal: 5.92 ± 14.48 vs. 0.97 ± 4.15, ρ=0.008; 100g meal: 9.5 ± 17.02 vs. 1.85 ± 7.05, ρ=0.014). In a single day scenario, considering intra-patient variability, the time in hypoglycemia was reduced (9.57 ± 14.48 vs. 4.21 ± 6.18, ρ=0.028) and improved the time in euglycemia (79.46 ± 17.46 vs. 86.29 ± 11.73, ρ=0.007). The automatic IOB-based SB has the potential of a better performance in comparison with the standard treatment, particularly for high glycemic index meals with high carbohydrate content. Both glucose excursion and time spent in hypoglycemia were reduced. Copyright © 2018 Elsevier B.V. All rights reserved.

  13. National Biomedical Tracer Facility. Project definition study

    Energy Technology Data Exchange (ETDEWEB)

    Schafer, R.

    1995-02-14

    We request a $25 million government-guaranteed, interest-free loan to be repaid over a 30-year period for construction and initial operations of a cyclotron-based National Biomedical Tracer Facility (NBTF) in North Central Texas. The NBTF will be co-located with a linear accelerator-based commercial radioisotope production facility, funded by the private sector at approximately $28 million. In addition, research radioisotope production by the NBTF will be coordinated through an association with an existing U.S. nuclear reactor center that will produce research and commercial radioisotopes through neutron reactions. The combined facilities will provide the full range of technology for radioisotope production and research: fast neutrons, thermal neutrons, and particle beams (H{sup -}, H{sup +}, and D{sup +}). The proposed NBTF facility includes an 80 MeV, 1 mA H{sup -} cyclotron that will produce proton-induced (neutron deficient) research isotopes.

  14. Use of radioactive tracers in chemical reactions

    International Nuclear Information System (INIS)

    Paci, B.; Saiki, M.

    1979-01-01

    A method for the determination of small quantities of nickel by using radioactive tracers is presented. An analytical application of the displacement reaction between and zinc-ethylenediaminetetraacetate, (Zn-EDTA), labelled with 65 Zn is investigated. This method is based on the extraction of radioactive zinc, displaced by nickel from the zinc chelate, into a dithizone-carbon tetrachloride solution and the subsequent measurement of the activity of an aliquot of the extract. It is shown that the method is very sentitive and nickel can be measured in concentrations as small as 0,1μg/ml or even less, depending on the specific activity of the radioreagent used. The precision and accuracy of the method are determined. An attempt to eliminate the problem of interference by using masking agents or by means of a previous separation of nickel and other interfereing metals, is also made. (Author) [pt