WorldWideScience

Sample records for trace level high

  1. Identification of trace levels of selenomethionine and related organic selenium species in high-ionic-strength waters.

    Science.gov (United States)

    LeBlanc, Kelly L; Ruzicka, Josef; Wallschläger, Dirk

    2016-02-01

    A new anion-exchange chromatographic separation method was used for the simultaneous speciation analysis of selenoamino acids and the more ubiquitous inorganic selenium oxyanions, selenite and selenate. For quantification, this separation was coupled to inductively coupled plasma-mass spectrometry to achieve an instrumental detection limit of 5 ng Se L(-1) for all species. This chromatographic method was also coupled to electrospray tandem mass spectrometry to observe the negative ion mode fragmentation of selenomethionine and one of its oxidation products. Low detection limits were achieved, which were similar to those obtained using inductively coupled plasma-mass spectrometry. An extensive preconcentration and cleanup procedure using cation-exchange solid-phase extraction was developed for the identification and quantification of trace levels of selenomethionine in environmental samples. Preconcentration factors of up to five were observed for selenomethionine, which in addition to the removal of high concentrations of sulphate and chloride from industrial process waters, allowed for an unambiguous analysis that would have been impossible otherwise. Following these methods, selenomethionine was identified at an original concentration of 3.2 ng Se L(-1) in samples of effluent collected at a coal-fired power plant's biological remediation site. It is the first time that this species has been identified in the environment, outside of a biological entity. Additionally, oxidation products of selenomethionine were identified in river water and laboratory algal culture samples. High-resolution mass spectrometry was employed to postulate the chemical structures of these species.

  2. Trace elements levels in centenarian 'dodgers'.

    Science.gov (United States)

    Alis, Rafael; Santos-Lozano, Alejandro; Sanchis-Gomar, Fabian; Pareja-Galeano, Helios; Fiuza-Luces, Carmen; Garatachea, Nuria; Lucia, Alejandro; Emanuele, Enzo

    2016-05-01

    Trace element bioavailability can play a role in several metabolic and physiological pathways known to be altered during the aging process. We aimed to explore the association of trace elements with increased lifespan by analyzing the circulating levels of seven trace elements (Cr, Cu, Fe, Mn, Mo, Se and Zn) in a cohort of healthy centenarians or 'dodgers' (≥100 years, free of major age-related diseases) in comparison with sex-matched younger elderly controls. Centenarians showed significant lower Cu (783.7 (76.7, 1608.9) vs 962.5 (676.3, 2064.4)μg/mL, Pdodgers', and, therefore, at least partly, be involved in the healthy aging phenotype shown by these subjects. These results should be confirmed in larger cohorts of other geographic/ethnic origin and the potential cause-effect association tested in mechanistic experimental settings. Copyright © 2016 Elsevier GmbH. All rights reserved.

  3. Thiourea-treated graphene aerogel as a highly selective gas sensor for sensing of trace level of ammonia

    Energy Technology Data Exchange (ETDEWEB)

    Alizadeh, Taher, E-mail: talizadeh@ut.ac.ir [Department of Analytical Chemistry, Faculty of Chemistry, University College of Science, University of Tehran, P.O. Box 14155-6455, Tehran (Iran, Islamic Republic of); Ahmadian, Farzaneh [Department of Applied Chemistry, Faculty of Science, University of Mohaghegh Ardabili, Daneshgah Street, P.B179, 56199-11367 Ardabil (Iran, Islamic Republic of)

    2015-10-15

    As a result of this study, a new and simple method was proposed for the fabrication of an ultra sensitive, robust and reversible ammonia gas sensor. The sensing mechanism was based upon the change in electrical resistance of a graphene aerogel as a result of sensor exposing to ammonia. Three-dimensional graphene hydrogel was first synthesized via hydrothermal method in the absence or presence of various amounts of thiourea. The obtained material was heated to obtain aerogel and then it was used as ammonia gas sensor. The materials obtained were characterized using different techniques such as Fourier transform infrared spectroscopy (FT-IR), thermal gravimetric analysis (TGA), X-ray diffraction (XRD) and scanning electron microscopy (SEM). The thiourea-treated graphene aerogel was more porous (389 m{sup 2} g{sup −1}) and thermally unstable and exhibited higher sensitivity, shorter response time and better selectivity toward ammonia gas, compared to the aerogel produced in the absence of thiourea. Thiourea amount, involved in the hydrogel synthesis step, was found to be highly effective factor in the sensing properties of finally obtained aerogel. The sensor response time to ammonia was short (100 s) and completely reversible (recovery time of about 500 s) in ambient temperature. The sensor response to ammonia was linear between 0.02 and 85 ppm and its detection limit was found to be 10 ppb (3S/N). - Highlights: • An ammonia gas sensor with ppb level determination capability was proposed. • A new procedure has been introduced for gas sensor fabrication by graphene hydrogel. • Thiourea-treated graphene aerogel was used as excellent ammonia gas sensor.

  4. Levels and occupational health risk assessment of trace metals in ...

    African Journals Online (AJOL)

    The levels of trace metals (Pb, Cu, Ni and Cd) were determined in soils from a major automobile repair workshop located in Uyo, Akwa Ibom State, Nigeria. This was carried out to evaluate the potential occupational risk to operators working in and around the site. The mean of trace metal levels were: lead (14.52 mg/kg); ...

  5. Trace elements levels in centenarian ‘dodgers’

    OpenAIRE

    Alis, Rafael; Santos-Lozano, Alejandro; Sanchís-Gomar, Fabián; Pareja Galeano, Helios; Fiuza Luces, María del Carmen; Garatachea, Nuria; Lucía Mulas, Alejandro; Emanuele, Enzo

    2016-01-01

    Trace element bioavailability can play a role in several metabolic and physiological pathways known to be altered during the aging process. We aimed to explore the association of trace elements with increased lifespan by analyzing the circulating levels of seven trace elements (Cr, Cu, Fe, Mn, Mo, Se and Zn) in a cohort of healthy centenarians or ‘dodgers’ (≥100 years, free of major age-related diseases) in comparison with sex-matched younger elderly controls. Centenarians showed significant ...

  6. Serum Lipids and Lipoproteins Levels and Selected Trace Metals In ...

    African Journals Online (AJOL)

    This study aim to determine the serum levels of trace metals and correlate same with serum levels of lipoproteins (an established marker of HBP) in newly diagnosed hypertensives (NDH) A total of 50 NDH subjects (24 males and 26 females) attending Ladoke Akintola University of Technology Teaching Hospital, Osogbo ...

  7. Ben Macdhui High Altitude Trace Gas and Aerosol Transport Experiment

    CSIR Research Space (South Africa)

    Piketh, SJ

    1999-01-01

    Full Text Available The Ben Macdhui High Altitude Aerosol and Trace Gas Transport Experiment (BHATTEX) was started to characterize the nature and magnitude of atmospheric, aerosol and trace gas transport paths recirculation over and exiting from southern Africa...

  8. Detection and Analytical Capabilities for Trace Level of Carbon in High-Purity Metals by Laser-Induced Breakdown Spectroscopy with a Frequency Quintupled 213 nm Nd:YAG Laser

    Directory of Open Access Journals (Sweden)

    Masaki Ohata

    2017-01-01

    Full Text Available The laser-induced breakdown spectroscopy (LIBS with a frequency quintupled 213 nm Nd:YAG laser was examined to the analysis of trace level of carbon (C in high-purity metals and its detection and analytical capabilities were evaluated. Though C signal in a wavelength of 247.9 nm, which showed the highest sensitivity of C, could be obtained from Cd, Ti, and Zn ca. 7000 mg kg−1 C in Fe could not be detected due to the interferences from a lot of Fe spectra. Alternative C signal in a wavelength of 193.1 nm could not be also detected from Fe due to the insufficient laser output energy of the frequency quintupled 213 nm Nd:YAG laser. The depth analysis of C by LIBS was also demonstrated and the C in Cd and Zn was found to be contaminated in only surface area whereas the C in Ti was distributed in bulk. From these results, the frequency quintupled 213 nm Nd:YAG laser, which was adopted widely as a commercial laser ablation (LA system coupled with inductively coupled plasma mass spectrometry (ICPMS for trace element analysis in solid materials, could be used for C analysis to achieve simultaneous measurements for both C and trace elements in metals by LIBS and LA-ICPMS, respectively.

  9. Trace and ultratrace level elemental and speciation analysis

    International Nuclear Information System (INIS)

    Arunachalam, J.

    2012-01-01

    Accurate determination of elements present at parts per million and billion levels in various matrices is a growing requirement in different fields. In environmental sciences various trace elements need to be analyzed so as establish the dispersal models of pollutants or the adequacy of effluent treatment prior to discharge into water bodies. The issues of bioaccumulation and magnification are important in aquatic systems. In nutrition and biochemistry one has to establish the bio-availability of essential and toxic elemental species as toxic elements prevent assimilation of essential elements. Fission and fusion technologies use a variety of structural materials requiring many trace elements to be present at levels strictly below the specified levels. Ultra-pure bulk semiconductor materials are required for fabrication devices. In metallurgy and materials sciences too, various trace elements are known to influence the properties. In the emerging fields like nanotechnology, it is necessary to understand the passage and accumulation of nano-particles inside the cells, through trace analysis. Many analytical techniques exist which can provide the concentration information in the bulk materials with good accuracy. They include ICP-AES, FAAS, and ICP-MS, which are solution based techniques. Direct solid state analytical techniques are Glow Discharge Mass Spectrometry (GDMS) and XRF. Accelerator based ion-beam analysis techniques can provide information on concentration and depth profiles of different elements in layered structures. Hyphenated techniques such as HPLC/lC-ICPMS, are helpful in identifying various chemical oxidation states in which a given element might be present in a matrix, which is termed as speciation analysis. This presentation will include the existing analytical competencies and the laboratory requirements for trace and ultra trace element elemental and speciation analyses and their applications. (author)

  10. Trace Metal Levels in Raw and Heat Processed Nigerian Staple ...

    African Journals Online (AJOL)

    The levels of some trace metals (Fe, Zn, Cu, Ni, Cd) were quantitatively determined in raw and heat processed staple food cultivars (yam, cassava, cocoyam and maize) from oil producing areas of part of the Niger Delta and compared with a non-oil producing area of Ebonyi State as control. The survey was conducted to ...

  11. Comparison of trace element contamination levels (Cu, Zn, Fe, Cd ...

    African Journals Online (AJOL)

    Comparison of trace element contamination levels (Cu, Zn, Fe, Cd and Pb) in the soft tissues of the gastropods Tympanotonus fuscatus fuscatus and Tf radula collected in the Ebrié Lagoon (Côte d'Ivoire): Evidence of the risks linked to linked to lead and.

  12. Trace metals and vitamin levels in Nigerian patients with sensory ...

    African Journals Online (AJOL)

    The significance of the higher levels of magnesium in the patients is unclear and needs further investigation. Further studies with larger sample sizes are needed to confirm this observation. Keywords: ataxia, trace metals, vitamins, Nigerians Nigerian Journal of Health and Biomedical Sciences Vol. 4(2) 2005: 156–160 ...

  13. Application of Box-Behnken design to optimize multi-sorbent solid phase extraction for trace neonicotinoids in water containing high level of matrix substances.

    Science.gov (United States)

    Zhang, Junjie; Wei, Yanli; Li, Huizhen; Zeng, Eddy Y; You, Jing

    2017-08-01

    Extensive use of neonicotinoid insecticides has raised great concerns about their ecological risk. A reliable method to measure trace neonicotinoids in complicated aquatic environment is a premise for assessing their aquatic risk. To effectively remove matrix interfering substances from field water samples before instrumental analysis with HPLC/MS/MS, a multi-sorbent solid phase extraction method was developed using Box-Behnken design. The optimized method employed 200mg HLB/GCB (w/w, 8/2) as the sorbents and 6mL of 20% acetone in acetonitrile as the elution solution. The method was applied for measuring neonicotinoids in water at a wide range of concentrations (0.03-100μg/L) containing various amounts of matrix components. The recoveries of acetamiprid, imidacloprid, thiacloprid and thiamethoxam from the spiked samples ranged from 76.3% to 107% while clothianidin and dinotefuran had relatively lower recoveries. The recoveries of neonicotinoids in water with various amounts of matrix interfering substances were comparable and the matrix removal rates were approximately 50%. The method was sensitive with method detection limits in the range of 1.8-6.8ng/L for all target neonicotinoids. Finally, the developed method was validated by measurement of trace neonicotinoids in natural water. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Trace metal levels in sediments of Pearl Harbor (Hawaii)

    International Nuclear Information System (INIS)

    Ashwood, T.L.; Olsen, C.R.; Larsen, I.L.; Tamura, T.

    1986-09-01

    This study was conducted to measure the distribution of lead and other trace metals in the sediments of Pearl Harbon (Hawaii) to determine whether paint chips from vessels of the US Navy's Inactive Fleet have affected the environmental quality of Middle Loch. Sediment cores (ranging from 0.5 to 3.0 m long) were collected from Middle Loch near the Naval Inactive Ships Maintenance Facility and in an area of West Loch that is relatively isolated and unaffected by naval operations. Concentrations of copper, lead, and zinc averaged 180 μg/g, 49 μg/g, and 272 μg/g, respectively, in recent Middle Loch sediments. These concentrations are significantly higher than those in either historical Middle Loch sediments or recent West Loch sediments. However, except for lead, the concentrations in recent Middle Loch sediments are similar to those of older Middle Loch sediments, which indicates that the increase in trace metal contamination began before the onset of Inactive Fleet operations (about 1946). Increased trace metal levels in recent Middle Loch sediments might be expected to result from two potential sources: (1) sewage discharges and (2) paint from inactive vessels. Since paint contains elevated levels of lead and zinc but little copper, the elevated copper levels in Middle Loch sediments tend to implicate sewage as the source of trace metal contamination. Moreover, the lead:zinc ratio of recent Middle Loch sediments (0.18:1) is a factor of 10 lower than that measured in paint (2.1:1), and the Middle Loch lead:zinc ratio is not significantly greater than that measured in recent West Loch sediments (0.21:1). Hence, we suggest that sewage rather than paint is the major source of trace metal contamination of Middle Loch. This is consistent with the findings of a previous study by US navy personnel

  15. Levels of trace elements in MWSS drinking water

    International Nuclear Information System (INIS)

    Andal, T.T.

    1998-01-01

    As a water supplier for the metropolis, vigilance over the water quality has not been taken for granted at the Metropolitan Waterworks and Sewerage System (MWSS). By the early 1980's, a control laboratory equipped with modern facilities had been set up to supplement the already existing control laboratory at Filter Plant II handling physical, chemical, bacteriological, biological and mineral analyses and examinations, efficiently. The new central laboratory is intended to monitor trace elements, organic constituents and other elements with health related impact so as to assure the consumers of a safe drinking water supply at all times. This presentation reviews the levels of trace element pollution in MWSS tap water, then and now, in justification of the rehabilitation projects along the distribution network, in the treatment plants and other pertinent innovations corresponding to budgeted capital outlays as invested by the system. (author)

  16. Speciation of arsenic in water samples by high-performance liquid chromatography-hydride generation-atomic absorption spectrometry at trace levels using a post-column reaction system

    Energy Technology Data Exchange (ETDEWEB)

    Stummeyer, J. [Bundesanstalt fuer Geowissenschaften und Rohstoffe, Hannover (Germany); Harazim, B. [Bundesanstalt fuer Geowissenschaften und Rohstoffe, Hannover (Germany); Wippermann, T. [Bundesanstalt fuer Geowissenschaften und Rohstoffe, Hannover (Germany)

    1996-02-01

    Anion-exchange HPLC has been combined with hydride generation - atomic absorption spectrometry (HG-AAS) for the routine speciation of arsenite, arsenate, monomethylarsenic acid and dimethylarsinic acid. The sensitivity of the AAS-detection was increased by a post-column reaction system to achieve complete formation of volatile arsines from the methylated species and arsenate. The system allows the quantitative determination of 0.5 {mu}g/l of each arsenic compound in water samples. The stability of synthetical and natural water containing arsenic at trace levels was investigated. To preserve stored water samples, a method for quantitative separation of arsenate at high pH-values with the basic anion-exchange resin Dowex 1 x 8 was developed. (orig.)

  17. Chronocoulometric determination of trace levels of uranium in rocks

    International Nuclear Information System (INIS)

    Cantagallo, M.I.C.; Gutz, I.G.R.

    1990-01-01

    The chronocoulometric method for the determination of trace levels of uranium, based on the catalytic nitrate reduction was applied with real and synthetic samples. Reference materials with complex matrices like rocks were first solubilized by hot digestion under pressure in a PTFE bomb. When necessary, an adapted liquid-liquid extraction procedure was used for previous separation of interferents. The obtained results are in good agreement with the values obtained with other techniques such as X-ray fluorescence, mass spectrometry -isotope dilution and apithermal activation analysis. (author) [pt

  18. A multiresidue method by high performance liquid chromatography-based fractionation and gas chromatographic determination of trace levels of pesticides in air and water.

    Science.gov (United States)

    Seiber, J N; Glotfelty, D E; Lucas, A D; McChesney, M M; Sagebiel, J C; Wehner, T A

    1990-01-01

    A multiresidue analytical method is described for pesticides, transformation products, and related toxicants based upon high performance liquid chromatographic (HPLC) fractionation of extracted residue on a Partisil silica gel normal phase column followed by selective-detector gas chromatographic (GC) determination of components in each fraction. The HPLC mobile phase gradient (hexane to methyl t-butyl ether) gave good chromatographic efficiency, resolution, reproducibility and recovery for 61 test compounds, and allowed for collection in four fractions spanning polarities from low polarity organochlorine compounds (fraction 1) to polar N-methylcarbamates and organophosphorus oxons (fraction 4). The multiresidue method was developed for use with air samples collected on XAD-4 and related trapping agents, and water samples extracted with methylene chloride. Detection limits estimated from spiking experiments were generally 0.3-1 ng/m3 for high-volume air samples, and 0.01-0.1 microgram/L for one-liter water samples. Applications were made to determination of pesticides in fogwater and air samples.

  19. Rapid trace level determination of sulfonamide residues in honey with online extraction using short C-18 column by high-performance liquid chromatography with fluorescence detection.

    Science.gov (United States)

    Sajid, Muhammad; Na, Na; Safdar, Muhammad; Lu, Xin; Ma, Lin; He, Lan; Ouyang, Jin

    2013-11-01

    A sensitive and inexpensive quantification method with online extraction using a short C-18 column for sulfonamide residues in honey by high performance liquid chromatography with fluorescence detector was developed and validated. In sample preparation, acid hydrolysis was used to break the N-glycoside bond between the honey sugar and sulfonamide drugs and derivatization of sulfonamide residues with fluorescamine was conducted at pH 3.5 using a citrate buffer (0.5M) in the honey matrix. The chromatography was carried out on Zorbax Extended C-18 (250mm×4.6mm; 5μm) column, using a mixture of acetonitrile and an acetate buffer (pH 4.50, 20mM) as a mobile phase. A Zorbax Extended C-18 (12mm×4.6mm; 5μm) column was used for online extraction of fifteen sulfonamide residues from honey sample with the help of a two position valve. The limit of quantification of sulfonamide residues in honey was less than 3ngg(-1), and the percentage recovery of study compounds in spiked honey sample was from 80% for sulfacetamide to 100% of sulfachloropyridazine. The developed method has excellent linearity for all studied sulfonamides with a correlation coefficient 0.993. Copyright © 2013 Elsevier B.V. All rights reserved.

  20. Determination of trace levels of uranium and thorium in high purity gadolinium sulfate using the ICP-MS with solid-phase chromatographic extraction resin

    Science.gov (United States)

    Ito, S.; Takaku, Y.; Ikeda, M.; Kishimoto, Y.

    2017-11-01

    The new Super-Kamiokande-Gadolinium (SK-Gd) project is an upgrade of the Super-Kamiokande (SK) detector. In the SK-Gd project, 0.2% Gd_2(SO_4)_3 is loaded into the 50 kton water tank of the SK. One of the main purposes of the project is to discover supernova relic neutrinos. Neutrino measurements and proton decay searches will also be performed in the SK-Gd. In order to measure solar neutrinos with a low energy threshold of ˜3.5 MeV in the SK-Gd, the main radioactive contaminations, ^{238}U and ^{232}Th, in Gd_2(SO_4)_3{\\cdot}8H_2O, should be minimized before loading. Our maximum levels for U and Th are 5 mBq (U)/kg (Gd_2(SO_4)_3{\\cdot}8H_2O) and 0.05 mBq (Th)/kg (Gd_2(SO_4)_3{\\cdot}8H_2O). In order to measure such low concentrations of U and Th in Gd_2(SO_4)_3{\\cdot}8H_2O, we developed the solid-phase extraction technique. Using this method, about 90% or more U and Th could be efficiently extracted while Gd was reduced by a factor of about 104. This allowed these radioactivity contaminations to be measured precisely as 0.04 mBq/kg (Gd_2(SO_4)_3{\\cdot}8H_2O) for U and 0.01 mBq/kg (Gd_2(SO_4)_3{\\cdot}8H_2O) for Th. We measured three pure Gd_2(SO_4)_3{\\cdot}8H_2O samples using this method and estimated that the purest one contained <0.04 mBq (U)/kg (Gd_2(SO_4)_3{\\cdot}8H_2O) and 0.06 ± 0.01 mBq (Th)/kg (Gd_2(SO_4)_3{\\cdot}8H_2O) by the ICP-MS.

  1. Determination of Trace Level Triclosan in Water by Online Preconcentration and HPLC-UV Diode Array

    Science.gov (United States)

    An online high performance liquid chromatography (HPLC) method for the detection and quantification of trace levels of triclosan in water is discussed. Triclosan, an anti-bacterial agent, and related compounds have been shown to reach municipal waste waters through the disposal ...

  2. Electron ray tracing with high accuracy

    International Nuclear Information System (INIS)

    Saito, K.; Okubo, T.; Takamoto, K.; Uno, Y.; Kondo, M.

    1986-01-01

    An electron ray tracing program is developed to investigate the overall geometrical and chromatic aberrations in electron optical systems. The program also computes aberrations due to manufacturing errors in lenses and deflectors. Computation accuracy is improved by (1) calculating electrostatic and magnetic scalar potentials using the finite element method with third-order isoparametric elements, and (2) solving the modified ray equation which the aberrations satisfy. Computation accuracy of 4 nm is achieved for calculating optical properties of the system with an electrostatic lens

  3. Trace gases over Northern Eurasia: background level and disturbing factors

    Science.gov (United States)

    Skorokhod, A.; Shumsky, R.; Pankratova, N.; Moiseenko, K.; Vasileva, A.; Berezina, E.; Elansky, N.

    2012-04-01

    Atmospheric air composition over the vast and low inhabited areas of Northern Eurasia is still poorly studied because of lack of the precise direct measurements. This harms to accuracy of both global and regional models which simulate climatological and ecosystem changes in that highly important region. In this work background trace gases (such as O3, NO, NO2, CO) concentrations and their variability are considered on base of results of continuous measurements at ZOTTO station in the middle of Siberia which have been carried out since March, 2007. Also factors implying background regime (like long-range transport, wild fires emissions) are analyzed. To compliment study data of TROICA train-based campaigns which have been regularly provided across Russia for many years (1995-2010) are used. The concentration of ozone has a pronounced seasonal variation with a clear peak in spring (40-45 ppbv in average and up to 80 ppbv in extreme cases) and minimum in winter. Average ozone level is about 20 ppbv that corresponds to the background conditions. Enhanced concentration in March-July is due to increased stratospheric-tropospheric exchange. In autumn and winter distribution of ozone is close to uniform. Photochemical processes under low light and air temperature does not cause the generation of ozone. Sink on the snow surface is very small, and therefore the diurnal variations are absent. In general, seasonal variations correspond to the average seasonal course, which is typical for Russia. The analysis of diurnal ozone variations in Zotino in different seasons showed that the maximum rate of ozone formation is observed in summer from 9 to 15 h local time and is 1-2 ppbv/hour. It correlates well with the data on the isoprene emissions and others biogenic VOC reacting with OH- radical. Thus they are biogenic VOC emissions that seem to be the main factor of the lower troposphere oxidation power in summer. In other seasons it is significantly lower. NOx concentration does

  4. High precision ray tracing in cylindrically symmetric electrostatics

    Energy Technology Data Exchange (ETDEWEB)

    Edwards Jr, David, E-mail: dej122842@gmail.com

    2015-11-15

    Highlights: • High precision ray tracing is formulated using power series techniques. • Ray tracing is possible for fields generated by solution to laplace's equation. • Spatial and temporal orders of 4–10 are included. • Precisions in test geometries of hemispherical deflector analyzer of ∼10{sup −20} have been obtained. • This solution offers a considerable extension to the ray tracing accuracy over the current state of art. - Abstract: With the recent availability of a high order FDM solution to the curved boundary value problem, it is now possible to determine potentials in such geometries with considerably greater accuracy than had been available with the FDM method. In order for the algorithms used in the accurate potential calculations to be useful in ray tracing, an integration of those algorithms needs to be placed into the ray trace process itself. The object of this paper is to incorporate these algorithms into a solution of the equations of motion of the ray and, having done this, to demonstrate its efficacy. The algorithm incorporation has been accomplished by using power series techniques and the solution constructed has been tested by tracing the medial ray through concentric sphere geometries. The testing has indicated that precisions of ray calculations of 10{sup −20} are now possible. This solution offers a considerable extension to the ray tracing accuracy over the current state of art.

  5. Comparison of trace element contamination levels (Cu, Zn, Fe, Cd ...

    African Journals Online (AJOL)

    SERVER

    2008-03-18

    Mar 18, 2008 ... Chemical analysis of the trace elements in the soft tissues. The trace elements of interest (Cu, Zn, Fe, Pb, Cd) were then determined in the digested solutions, using Thermoelemental type. M6 brand of an atomic absorption Spectrometer equipped with a flame operated atomisation system and a deuterium ...

  6. Neural population-level memory traces in the mouse hippocampus.

    Science.gov (United States)

    Chen, Guifen; Wang, L Phillip; Tsien, Joe Z

    2009-12-16

    One of the fundamental goals in neurosciences is to elucidate the formation and retrieval of brain's associative memory traces in real-time. Here, we describe real-time neural ensemble transient dynamics in the mouse hippocampal CA1 region and demonstrate their relationships with behavioral performances during both learning and recall. We employed the classic trace fear conditioning paradigm involving a neutral tone followed by a mild foot-shock 20 seconds later. Our large-scale recording and decoding methods revealed that conditioned tone responses and tone-shock association patterns were not present in CA1 during the first pairing, but emerged quickly after multiple pairings. These encoding patterns showed increased immediate-replay, correlating tightly with increased immediate-freezing during learning. Moreover, during contextual recall, these patterns reappeared in tandem six-to-fourteen times per minute, again correlating tightly with behavioral recall. Upon traced tone recall, while various fear memories were retrieved, the shock traces exhibited a unique recall-peak around the 20-second trace interval, further signifying the memory of time for the expected shock. Therefore, our study has revealed various real-time associative memory traces during learning and recall in CA1, and demonstrates that real-time memory traces can be decoded on a moment-to-moment basis over any single trial.

  7. Neural population-level memory traces in the mouse hippocampus.

    Directory of Open Access Journals (Sweden)

    Guifen Chen

    2009-12-01

    Full Text Available One of the fundamental goals in neurosciences is to elucidate the formation and retrieval of brain's associative memory traces in real-time. Here, we describe real-time neural ensemble transient dynamics in the mouse hippocampal CA1 region and demonstrate their relationships with behavioral performances during both learning and recall. We employed the classic trace fear conditioning paradigm involving a neutral tone followed by a mild foot-shock 20 seconds later. Our large-scale recording and decoding methods revealed that conditioned tone responses and tone-shock association patterns were not present in CA1 during the first pairing, but emerged quickly after multiple pairings. These encoding patterns showed increased immediate-replay, correlating tightly with increased immediate-freezing during learning. Moreover, during contextual recall, these patterns reappeared in tandem six-to-fourteen times per minute, again correlating tightly with behavioral recall. Upon traced tone recall, while various fear memories were retrieved, the shock traces exhibited a unique recall-peak around the 20-second trace interval, further signifying the memory of time for the expected shock. Therefore, our study has revealed various real-time associative memory traces during learning and recall in CA1, and demonstrates that real-time memory traces can be decoded on a moment-to-moment basis over any single trial.

  8. Sensitive Multi-Species Emissions Monitoring: Infrared Laser-Based Detection of Trace-Level Contaminants

    Energy Technology Data Exchange (ETDEWEB)

    Steill, Jeffrey D. [Sandia National Lab. (SNL-CA), Livermore, CA (United States); Huang, Haifeng [Sandia National Lab. (SNL-CA), Livermore, CA (United States); Hoops, Alexandra A. [Sandia National Lab. (SNL-CA), Livermore, CA (United States); Patterson, Brian D. [Sandia National Lab. (SNL-CA), Livermore, CA (United States); Birtola, Salvatore R. [Sandia National Lab. (SNL-CA), Livermore, CA (United States); Jaska, Mark [Sandia National Lab. (SNL-CA), Livermore, CA (United States); Strecker, Kevin E. [Sandia National Lab. (SNL-CA), Livermore, CA (United States); Chandler, David W. [Sandia National Lab. (SNL-CA), Livermore, CA (United States); Bisson, Soott [Sandia National Lab. (SNL-CA), Livermore, CA (United States)

    2014-09-01

    This report summarizes our development of spectroscopic chemical analysis techniques and spectral modeling for trace-gas measurements of highly-regulated low-concentration species present in flue gas emissions from utility coal boilers such as HCl under conditions of high humidity. Detailed spectral modeling of the spectroscopy of HCl and other important combustion and atmospheric species such as H 2 O, CO 2 , N 2 O, NO 2 , SO 2 , and CH 4 demonstrates that IR-laser spectroscopy is a sensitive multi-component analysis strategy. Experimental measurements from techniques based on IR laser spectroscopy are presented that demonstrate sub-ppm sensitivity levels to these species. Photoacoustic infrared spectroscopy is used to detect and quantify HCl at ppm levels with extremely high signal-to-noise even under conditions of high relative humidity. Additionally, cavity ring-down IR spectroscopy is used to achieve an extremely high sensitivity to combustion trace gases in this spectral region; ppm level CH 4 is one demonstrated example. The importance of spectral resolution in the sensitivity of a trace-gas measurement is examined by spectral modeling in the mid- and near-IR, and efforts to improve measurement resolution through novel instrument development are described. While previous project reports focused on benefits and complexities of the dual-etalon cavity ring-down infrared spectrometer, here details on steps taken to implement this unique and potentially revolutionary instrument are described. This report also illustrates and critiques the general strategy of IR- laser photodetection of trace gases leading to the conclusion that mid-IR laser spectroscopy techniques provide a promising basis for further instrument development and implementation that will enable cost-effective sensitive detection of multiple key contaminant species simultaneously.

  9. High-level verification

    CERN Document Server

    Lerner, Sorin; Kundu, Sudipta

    2011-01-01

    Given the growing size and heterogeneity of Systems on Chip (SOC), the design process from initial specification to chip fabrication has become increasingly complex. This growing complexity provides incentive for designers to use high-level languages such as C, SystemC, and SystemVerilog for system-level design. While a major goal of these high-level languages is to enable verification at a higher level of abstraction, allowing early exploration of system-level designs, the focus so far for validation purposes has been on traditional testing techniques such as random testing and scenario-based

  10. High potassium level

    Science.gov (United States)

    ... level is very high, or if you have danger signs, such as changes in an ECG . Emergency ... Seifter JL. Potassium disorders. In: Goldman L, Schafer AI, eds. Goldman-Cecil Medicine . 25th ed. Philadelphia, PA: ...

  11. General Algorithm (High level)

    Indian Academy of Sciences (India)

    First page Back Continue Last page Overview Graphics. General Algorithm (High level). Iteratively. Use Tightness Property to remove points of P1,..,Pi. Use random sampling to get a Random Sample (of enough points) from the next largest cluster, Pi+1. Use the Random Sampling Procedure to approximate ci+1 using the ...

  12. The role of high-energy synchrotron radiation in biomedical trace element research

    International Nuclear Information System (INIS)

    Pounds, J.G.; Long, G.J.; Kwiatek, W.M.; Jones, K.W.; Gordon, B.M.; Hanson, A.L.

    1987-01-01

    This paper will present the results of an investigation of the distribution of essential elements in the normal hepatic lobule. the liver is the organ responsible for metabolism and storage of most trace elements. Although parenchymal hepatocytes are rather uniform histologically, morphometry, histochemistry, immunohistochemistry, and microdissection with microchemical investigations have revealed marked heterogeneity on a functional and biochemical level. Hepatocytes from the periportal and perivenous zones of the liver parrenchyma differ in oxidative energy metabolism, glucose uptake and output, unreagenesis, biotransformation, bile acid secretion, and palsma protein synthesis and secretion. Although trace elements are intimately involved in the regulation and maintenance of these functions, little is known regarding the heterogeneity of trace element localization of the liver parenchyma. Histochemical techniques for trace elements generally give high spatial resolution, but lack specificity and stoichiometry. Microdissection has been of marginal usefulness for trace element analyses due to the very small size of the dissected parenchyma. The characteristics of the high-energy x-ray microscope provide an effective approach for elucidating the trace element content of these small biological structures or regions. 5 refs., 1 fig., 1 tab

  13. Levels of trace metals in water and sediment from Tyume River and ...

    African Journals Online (AJOL)

    Levels of trace metals (Cd, Pb, Co, Zn Cu and Ni) were determined in water and sediment ... mg/l) and Pb (0.021 ± 0.004 to 0.035 ± 0.001 mg/l) were found in the river water, ... Key words: trace metals, water, sediment, farmland, Tyume River

  14. Addictive drugs and their duration affecting on trace elements levels in men

    International Nuclear Information System (INIS)

    Nadeem, A.; Iqbal, K.; Shafiq, T.; Rehman, S.

    2008-01-01

    During the drug addiction the blood biochemistry particularly level of trace elements in blood is widely affected. Eighty male addicts of various age groups along with seventeen normal subjects were studied. The plasma Zinc and manganese concentration was high in addict person as compared to normal subjects. Where as a significant decrease in iron concentration was observed in addicts. The plasma copper concentration was also low in addicts as compared to normal subjects. In conclusion drug addiction leads to many biochemical changes that may have detritus effects on health status of addicts. (author)

  15. Trace elements in home-produced eggs in Belgium: Levels and spatiotemporal distribution

    International Nuclear Information System (INIS)

    Waegeneers, Nadia; Hoenig, Michel; Goeyens, Leo; De Temmerman, Ludwig

    2009-01-01

    The purpose of this study was to evaluate the levels of arsenic, cadmium, lead, copper and zinc in home-produced eggs, soils and kitchen waste samples of private chicken owners in Belgium, and to determine spatiotemporal differences in trace element contents in eggs. Eggs were sampled in all provinces of Belgium in autumn 2006 and spring 2007. A total number of 59 private chicken owners participated in the study. Trace elements were determined by inductively coupled plasma-mass spectrometry except for mercury, which was determined by atomic absorption of mercury vapour. The mean fresh weight concentrations in eggs in autumn and spring respectively were < 8.0 and < 8.0 μg/kg for arsenic, 0.5 and < 0.5 μg/kg for cadmium, 116 and 74 μg/kg for lead, 0.43 and 0.52 mg/kg for copper, 20.3 and 19.2 mg/kg for zinc, and 3.15 and 4.44 μg/kg for mercury. Analysis of variance determined significant differences in some trace element concentrations in eggs among seasons and regions in Belgium. Average concentrations of arsenic, cadmium and mercury corresponded well with values measured in other countries, while copper and zinc concentrations were within the same order of magnitude as in other countries. Average lead concentrations were high compared to concentrations in eggs from other countries and correlated well with lead concentrations in soil, indicating that the soil is an important source. Other sources of trace elements in eggs might be home-grown vegetables and forage (grass and herbs), and indirectly, air pollution.

  16. High level nuclear wastes

    International Nuclear Information System (INIS)

    Lopez Perez, B.

    1987-01-01

    The transformations involved in the nuclear fuels during the burn-up at the power nuclear reactors for burn-up levels of 33.000 MWd/th are considered. Graphs and data on the radioactivity variation with the cooling time and heat power of the irradiated fuel are presented. Likewise, the cycle of the fuel in light water reactors is presented and the alternatives for the nuclear waste management are discussed. A brief description of the management of the spent fuel as a high level nuclear waste is shown, explaining the reprocessing and giving data about the fission products and their radioactivities, which must be considered on the vitrification processes. On the final storage of the nuclear waste into depth geological burials, both alternatives are coincident. The countries supporting the reprocessing are indicated and the Spanish programm defined in the Plan Energetico Nacional (PEN) is shortly reviewed. (author) 8 figs., 4 tabs

  17. ALICE High Level Trigger

    CERN Multimedia

    Alt, T

    2013-01-01

    The ALICE High Level Trigger (HLT) is a computing farm designed and build for the real-time, online processing of the raw data produced by the ALICE detectors. Events are fully reconstructed from the raw data, analyzed and compressed. The analysis summary together with the compressed data and a trigger decision is sent to the DAQ. In addition the reconstruction of the events allows for on-line monitoring of physical observables and this information is provided to the Data Quality Monitor (DQM). The HLT can process event rates of up to 2 kHz for proton-proton and 200 Hz for Pb-Pb central collisions.

  18. A Global Overview of Exposure Levels and Biological Effects of Trace Elements in Penguins.

    Science.gov (United States)

    Espejo, Winfred; Celis, José E; GonzÃlez-Acuña, Daniel; Banegas, Andiranel; Barra, Ricardo; Chiang, Gustavo

    2018-01-01

    Trace elements are chemical contaminants that can be present almost anywhere on the planet. The study of trace elements in biotic matrices is a topic of great relevance for the implications that it can have on wildlife and human health. Penguins are very useful, since they live exclusively in the Southern Hemisphere and represent about 90% of the biomass of birds of the Southern Ocean. The levels of trace elements (dry weight) in different biotic matrices of penguins were reviewed here. Maps of trace element records in penguins were included. Data on exposure and effects of trace elements in penguins were collected from the literature. The most reported trace elements in penguins are aluminum, arsenic, cadmium, lead, mercury, copper, zinc, and manganese. Trace elements have been measured in 11 of the 18 species of penguins. The most studied biotic matrices are feathers and excreta. Most of the studies have been performed in Antarctica and subantarctic Islands. Little is known about the interaction among metals, which could provide better knowledge about certain mechanisms of detoxification in penguins. Future studies of trace elements in penguins must incorporate other metals such as vanadium, cobalt, nickel, and chromium. Data of metals in the species such as Eudyptes pachyrhynchus, Eudyptes moseleyi, Eudyptes sclateri, Eudyptes robustus, Eudyptes schlegeli, Spheniscus demersus, Spheniscus mendiculus, and Megadyptes antipodes are urged. It is important to correlate levels of metals in different biotic matrices with the effects on different species and in different geographic locations.

  19. Levels of some Trace Metals in Macroalgae from the Red Sea in Egypt

    International Nuclear Information System (INIS)

    Aboul-Naga, Wafiqa Mohamed

    2005-01-01

    The concentrations of iron (Fe), Zinc (Zn), manganese (Mn), Copper (Cu), chromium (Cr), nickel (Ni), and cobalt (Co) in ten macroalgae species from the Red Sea coastal water varied widely and also the trend of abundance of each metal also differed from one group to another. Concentration factors varied among species for iron (Fe) copper (Cu) manganese (Mn), but with iron (Fe) showing generally high concentration factors. Highly significant (P<0.05) relationships were found between manganese (Mn) and Nickel (Ni), and, Zinc (Zn) and copper (Cu). Moreover, moderate correlations were observed between manganese (Mn) and iron (Fe) and chromium (Cr), indicating that manganese (Mn) is the most accumulated metal in the macro algae of the Red Sea. In spite of the level of trace metals in the macro algae of the Red Sea. In spite of the level of trace metals in the macro algae, dominance is moderate relative to other sea areas subjected to intensive pollution. That is, the results indicated a nonpolluted environment. (author)

  20. Calculation correlations for radioisotope level gages with relay tracing systems

    International Nuclear Information System (INIS)

    Krejndlin, I.I.; Pakhunkov, Yu.I.

    1978-01-01

    The interrelationship was examined between the operational and instrumental parameters of radioisotope tracking level indicators. The relationships were obtained permitting to check the reliability of the tracking regime, and also of the equilibrium state of the radioisotope tracking level indicator

  1. Composition of Trace Metals in Dust Samples Collected from Selected High Schools in Pretoria, South Africa

    Directory of Open Access Journals (Sweden)

    J. O. Olowoyo

    2016-01-01

    Full Text Available Potential health risks associated with trace metal pollution have necessitated the importance of monitoring their levels in the environment. The present study investigated the concentrations and compositions of trace metals in dust samples collected from classrooms and playing ground from the selected high schools In Pretoria. Schools were selected from Pretoria based on factors such as proximity to high traffic ways, industrial areas, and residential areas. Thirty-two dust samples were collected from inside and outside the classrooms, where learners often stay during recess period. The dust samples were analysed for trace metal concentrations using Inductively Coupled Plasma-Mass Spectrometry (ICP-MS. The composition of the elements showed that the concentrations of Zn were more than all other elements except from one of the schools. There were significant differences in the concentrations of trace metals from the schools (p<0.05. Regular cleaning, proximity to busy road, and well maintained gardens seem to have positive effects on the concentrations of trace metals recorded from the classrooms dust. The result further revealed a positive correlation for elements such as Pb, Cu, Zn, Mn, and Sb, indicating that the dust might have a common source.

  2. Comparative study of trace element levels in some local vegetable ...

    African Journals Online (AJOL)

    The level of heavy metals in two varieties of vegetables harvested during the dry and wet seasons from seven different locations in Ilorin, Nigeria, were determined. The correlation between the level of metals in the vegetables and the irrigation water was also studied. Vegetables harvested during the dry season were found ...

  3. Serum levels of selected vitamins and trace elements in Nigerian ...

    African Journals Online (AJOL)

    Folic acid, vitamins and Zinc play essential role in DNA methylation but alcohol consumption is known to affect the levels of these micronutrients leading to risk of developing various illnesses and certain cancers. This study determined the levels of DNA methylation dependent-micronutrients (folate, vitamin B12, vitamin B6, ...

  4. Trace-level mercury removal from surface water

    International Nuclear Information System (INIS)

    Klasson, K.T.; Bostick, D.T.

    1998-01-01

    Many sorbents have been developed for the removal of mercury and heavy metals from waters; however, most of the data published thus far do not address the removal of mercury to the target levels represented in this project. The application to which these sorbents are targeted for use is the removal of mercury from microgram-per-liter levels to low nanogram-per-liter levels. Sorbents with thiouronium, thiol, amine, sulfur, and proprietary functional groups were selected for these studies. Mercury was successfully removed from surface water via adsorption onto Ionac SR-4 and Mersorb resins to levels below the target goal of 12 ng/L in batch studies. A thiol-based resin performed the best, indicating that over 200,000 volumes of water could be treated with one volume of resin. The cost of the resin is approximately $0.24 per 1,000 gal of water

  5. Physicochemical Characteristics and Trace Metal Levels of Locally ...

    African Journals Online (AJOL)

    Michael Horsfall

    Results from this study showed that the industrial and human activities in this study ... health hazard to their well water, and are therefore fit for their domestic activities. ... Bangladesh were natural levels of arsenic in ground ... This problem of.

  6. Trace metal levels in the sediments of the Cochin backwaters

    Digital Repository Service at National Institute of Oceanography (India)

    Venugopal, P.; Devi, K.S.; Remani, K.N.; Unnithan, R.V.

    Levels of Cu, Mn, Co, Ni and Zn at four stations in the northern arm of the Cochin backwaters, Kerala, India, which runs through an industrial belt is reported. All metals showed some degree of variation over the area studied. Co showed the lowest...

  7. Serum Levels of Selected Vitamins and Trace Elements in Nigerian ...

    African Journals Online (AJOL)

    olayemitoyin

    In addition to direct effects of alcohol on immune responses ... U/L. Cigarette smokers or those with high parasite densities ... Independent Student's t-test was used to compare the .... carotene, vitamins C and E, zinc and selenium are.

  8. LEVELS OF MAJOR AND TRACE METALS IN THE LEAVES AND ...

    African Journals Online (AJOL)

    B. S. Chandravanshi

    to meet some of their primary health care needs. In Africa, up to ... of children with high fever resulting from malaria is the use of herbal medicines at home [3]. Many of the .... Blending device (Moulex, France) and ceramic pestle and mortar were used for grinding and ..... minimize the risk of these two heavy metal toxicity.

  9. High blood cholesterol levels

    Science.gov (United States)

    Cholesterol - high; Lipid disorders; Hyperlipoproteinemia; Hyperlipidemia; Dyslipidemia; Hypercholesterolemia ... There are many types of cholesterol. The ones talked about most are: ... lipoprotein (HDL) cholesterol -- often called "good" cholesterol ...

  10. Mass-produced lonophore-based fluorescent microspheres for trace level determination of lead ions.

    Science.gov (United States)

    Telting-Diaz, Martin; Bakker, Eric

    2002-10-15

    The development and characterization of small, uniform, and mass-produced plasticized PVC-based sensing microspheres in view of rapid trace level analysis of lead ions is reported. Micrometer-sized particles obtained via an automated casting process were rendered selective for lead ions by doping them with highly selective components in a manner analogous to traditional optode sensing films. Single particles that contained the lipophilic ionophore N,N,N',N'-tetradodecyl-3-6-dioxaoctane-1-thio-8-oxodiamide (ETH 5493), the chromoionophore ETH 5418 together with a lipophilized indocarbocyanine derivative as internal reference dye (DiIC18), and lipophilic ion-exchanger sites sodium tetrakis[3,5-bistrifluoromethylphenyl]borate, yielded measurable lead responses at the low nanomolar level in pH buffered solutions. The detection limit for single particles was 3 x 10(-9) M at pH 5.7. The microspheres were fabricated via a reproducible formation of polymer droplets within a flowing aqueous phase followed by collection of spherical particles of approximately 13 microm in size. The particles were immobilized and assayed individually in a microflow cell via fluorescence microscopy. Selectivity patterns found were in agreement with those reported earlier for the lead-selective ligand ETH 5493, and all response functions were fully described by theory. In contrast to optode films that necessitated very long equilibration times and large sample volumes in diluted samples of analyte, particles exhibited extremely enhanced equilibrium response times. Thus, for lead sample concentrations at and above 5 x 10(-8) M, response times were approximately 3 min, whereas at the detection limit, complete equilibrium was recorded after just 15 min, with required sample volumes on the order of 1 mL This new class of microspheres appears to be suitable for rapid and sensitive ion detection at trace levels in environmental and biological applications.

  11. Infrequent dream recall associated with low performance but high overnight improvement on mirror-tracing.

    Science.gov (United States)

    Dumel, Gaëlle; Carr, Michelle; Marquis, Louis-Philippe; Blanchette-Carrière, Cloé; Paquette, Tyna; Nielsen, Tore

    2015-08-01

    Although sleep facilitates learning and memory, the roles of dreaming and habitual levels of recalling dreams remain unknown. This study examined if performance and overnight improvement on a rapid eye movement sleep-sensitive visuomotor task is associated differentially with habitually high or low dream recall frequency. As a relation between dream production and visuospatial skills has been demonstrated previously, one possibility is that frequency of dream recall will be linked to performance on visuomotor tasks such as the Mirror Tracing Task. We expected that habitually low dream recallers would perform more poorly on the Mirror Tracing Task than would high recallers and would show less task improvement following a night of sleep. Fifteen low and 20 high dream recallers slept one night each in the laboratory and performed the Mirror Tracing Task before and after sleep. Low recallers had overall worse baseline performance but a greater evening-to-morning improvement than did high recallers. Greater improvements in completion time in low recallers were associated with Stage 2 rather than rapid eye movement sleep. Findings support the separate notions that dreaming is related to visuomotor processes and that different levels of visuomotor skill engage different sleep- and dream-related consolidation mechanisms. © 2015 European Sleep Research Society.

  12. Trace radioactive measurement in foodstuffs using high purity germanium detector

    International Nuclear Information System (INIS)

    Morco, Ryan P.; Racho, Joseph Michael D.; Castaneda, Soledad S.; Almoneda, Rosalina V.; Pabroa, Preciosa Corazon B.; Sucgang, Raymond J.

    2010-01-01

    Trace radioactivity in food has been seriously considered sources of potential harm after the accidental radioactive releases in the last decades which led to contamination of the food chain. Countermeasures are being used to reduce the radiological health risk to the population and to ensure that public safety and international commitments are met. Investigation of radioactive traces in foods was carried out by gamma-ray spectrometry. The radionuclides being measured were fission products 1 37Cs and 1 34Cs and naturally occurring 4 0Κ. Gamma-ray measurements were performed using a hybrid gamma-ray counting system with coaxial p-type Tennelec High Purity Germanium (HPGe) detector with relative efficiency of 18.4%. Channels were calibrated to energies using a standard check source with 1 37Cs and 6 0Co present. Self-shielding within samples was taken into account by comparing directly with reference standards of similar matrix and geometry. Efficiencies of radionuclides of interests were accounted in calculating the activity concentrations in the samples. Efficiency calibration curve was generated using an in-house validated program called FINDPEAK, a least-square method that fits a polynomial up to sixth-order of equation. Lower Limits of Detection (LLD) obtained for both 1 37Cs and 1 34Cs ranges from 1-6 Bq/Kg depending on the sample matrix. In the last five years, there have been no foodstuffs analyzed exceeded the local and international regulatory limit of 1000Bq/Kg for the summed activities of 1 37Cs and 1 34Cs. (author)

  13. Trace elements in Antarctic fish species and the influence of foraging habitats and dietary habits on mercury levels

    Energy Technology Data Exchange (ETDEWEB)

    Goutte, Aurélie, E-mail: aurelie.goutte@ephe.sorbonne.fr [École Pratique des Hautes Études (EPHE), SPL, UPMC Univ Paris 06, UMR 7619 METIS, F-75005, 4 place Jussieu, Paris (France); Cherel, Yves [Centre d' Etudes Biologiques de Chizé, UMR 7372, CNRS-Université de La Rochelle, 79360 Villiers-en-Bois (France); Churlaud, Carine [Littoral Environnement et Sociétés (LIENSs), UMR 7266, CNRS-Université de la Rochelle, 2 rue Olympe de Gouges, 17000 La Rochelle (France); Ponthus, Jean-Pierre [École Pratique des Hautes Études (EPHE), SPL, UPMC Univ Paris 06, UMR 7619 METIS, F-75005, 4 place Jussieu, Paris (France); Massé, Guillaume [Unité Mixte Internationale Takuvik, Pavillon Alexandre-Vachon, Université Laval, QC, Québec (Canada); Bustamante, Paco [Littoral Environnement et Sociétés (LIENSs), UMR 7266, CNRS-Université de la Rochelle, 2 rue Olympe de Gouges, 17000 La Rochelle (France)

    2015-12-15

    This study aims at describing and interpreting concentration profiles of trace elements in seven Antarctic fish species (N = 132 specimens) off Adélie Land. Ichthyofauna plays a key role in the Antarctic ecosystem, as they occupy various ecological niches, including cryopelagic (ice-associated), pelagic, and benthic habitats. Firstly, trace element levels in the studied specimens were similar to those previously observed in fish from the Southern Ocean. Apart from manganese and zinc, concentrations of arsenic, cadmium, copper, iron, mercury (Hg), nickel, selenium and silver differed among fish species. Muscle δ{sup 13}C and δ{sup 15}N values were determined to investigate whether the fish foraging habitats and dietary habits could explain Hg levels. Species and foraging habitat (δ{sup 13}C) were strong predictors for variations of Hg concentrations in muscle tissues. The highest Hg contamination was found in shallow benthic fish compared to cryopelagic and pelagic fish. This pattern was likely due to the methylation of Hg in the coastal sediment and the photodemethylation by ultraviolet radiation in surface waters. - Highlights: • Trace elements and stable isotopes were analyzed in seven Antarctic fish species. • Levels of trace elements in liver and in muscle differed among species. • Hg load was higher in benthic fish than in cryopelagic and pelagic fish. • These findings could be due to the high methylation rate of Hg in the sediment.

  14. Trace elements in Antarctic fish species and the influence of foraging habitats and dietary habits on mercury levels

    International Nuclear Information System (INIS)

    Goutte, Aurélie; Cherel, Yves; Churlaud, Carine; Ponthus, Jean-Pierre; Massé, Guillaume; Bustamante, Paco

    2015-01-01

    This study aims at describing and interpreting concentration profiles of trace elements in seven Antarctic fish species (N = 132 specimens) off Adélie Land. Ichthyofauna plays a key role in the Antarctic ecosystem, as they occupy various ecological niches, including cryopelagic (ice-associated), pelagic, and benthic habitats. Firstly, trace element levels in the studied specimens were similar to those previously observed in fish from the Southern Ocean. Apart from manganese and zinc, concentrations of arsenic, cadmium, copper, iron, mercury (Hg), nickel, selenium and silver differed among fish species. Muscle δ"1"3C and δ"1"5N values were determined to investigate whether the fish foraging habitats and dietary habits could explain Hg levels. Species and foraging habitat (δ"1"3C) were strong predictors for variations of Hg concentrations in muscle tissues. The highest Hg contamination was found in shallow benthic fish compared to cryopelagic and pelagic fish. This pattern was likely due to the methylation of Hg in the coastal sediment and the photodemethylation by ultraviolet radiation in surface waters. - Highlights: • Trace elements and stable isotopes were analyzed in seven Antarctic fish species. • Levels of trace elements in liver and in muscle differed among species. • Hg load was higher in benthic fish than in cryopelagic and pelagic fish. • These findings could be due to the high methylation rate of Hg in the sediment.

  15. Green synthesis of gold nanoparticles for trace level detection of a hazardous pollutant (nitrobenzene) causing Methemoglobinaemia

    Energy Technology Data Exchange (ETDEWEB)

    Emmanuel, R. [Post Graduate and Research Department of Chemistry, Thiagarajar College, Madurai 625009, Tamil Nadu (India); Karuppiah, Chelladurai [Department of Chemical Engineering and Biotechnology, National Taipei University of Technology, Taipei 106, Taiwan, ROC (China); Chen, Shen-Ming, E-mail: smchen78@ms15.hinet.net [Department of Chemical Engineering and Biotechnology, National Taipei University of Technology, Taipei 106, Taiwan, ROC (China); Palanisamy, Selvakumar [Department of Chemical Engineering and Biotechnology, National Taipei University of Technology, Taipei 106, Taiwan, ROC (China); Padmavathy, S. [Department of Zoology and Microbiology, Thiagarajar College, Madurai 625009, Tamil Nadu (India); Prakash, P., E-mail: kmpprakash@gmail.com [Post Graduate and Research Department of Chemistry, Thiagarajar College, Madurai 625009, Tamil Nadu (India)

    2014-08-30

    Graphical abstract: Schematic representation for green synthesis of Au-NPs and its electroreduction of nitrobenzene. - Highlights: • A green synthesis of size controlled Au-NPs from plant extract. • Trace level detection of nitro benzene, a pollutant causing Methemoglobinaemia, at Au-NPs modified electrode. • Achievement of lower LOD and wider linear response. • The proposed sensor exhibits excellent practicality in various water samples. - Abstract: The present study involves a green synthesis of gold nanoparticles (Au-NPs) using Acacia nilotica twig bark extract at room temperature and trace level detection of one of the hazardous materials, viz. nitrobenzene (NB) that causes Methemoglobinaemia. The synthesis protocol demonstrates that the bioreduction of chloroauric acid leads to the formation of Au-NPs within 10 min, suggesting a higher reaction rate than any other chemical methods involved. The obtained Au-NPs have been characterized by UV–vis spectroscopy, X-ray diffraction, transmission electron microscopy, Energy-Dispersive X-ray Spectroscopy and Fourier Transform Infrared Spectroscopy. The electrochemical detection of NB has been investigated at the green synthesized Au-NPs modified glassy carbon electrode by using differential pulse voltammetry (DPV). The Au-NPs modified electrode exhibits excellent reduction ability toward NB compared to unmodified electrode. The developed NB sensor at Au-NPs modified electrode displays a wide linear response from 0.1 to 600 μM with high sensitivity of 1.01 μA μM{sup −1} cm{sup −2} and low limit of detection of 0.016 μM. The modified electrode shows exceptional selectivity in the presence of ions, phenolic and biologically coactive compounds. In addition, the Au-NPs modified electrode exhibits an outstanding recovery results toward NB in various real water samples.

  16. Green synthesis of gold nanoparticles for trace level detection of a hazardous pollutant (nitrobenzene) causing Methemoglobinaemia

    International Nuclear Information System (INIS)

    Emmanuel, R.; Karuppiah, Chelladurai; Chen, Shen-Ming; Palanisamy, Selvakumar; Padmavathy, S.; Prakash, P.

    2014-01-01

    Graphical abstract: Schematic representation for green synthesis of Au-NPs and its electroreduction of nitrobenzene. - Highlights: • A green synthesis of size controlled Au-NPs from plant extract. • Trace level detection of nitro benzene, a pollutant causing Methemoglobinaemia, at Au-NPs modified electrode. • Achievement of lower LOD and wider linear response. • The proposed sensor exhibits excellent practicality in various water samples. - Abstract: The present study involves a green synthesis of gold nanoparticles (Au-NPs) using Acacia nilotica twig bark extract at room temperature and trace level detection of one of the hazardous materials, viz. nitrobenzene (NB) that causes Methemoglobinaemia. The synthesis protocol demonstrates that the bioreduction of chloroauric acid leads to the formation of Au-NPs within 10 min, suggesting a higher reaction rate than any other chemical methods involved. The obtained Au-NPs have been characterized by UV–vis spectroscopy, X-ray diffraction, transmission electron microscopy, Energy-Dispersive X-ray Spectroscopy and Fourier Transform Infrared Spectroscopy. The electrochemical detection of NB has been investigated at the green synthesized Au-NPs modified glassy carbon electrode by using differential pulse voltammetry (DPV). The Au-NPs modified electrode exhibits excellent reduction ability toward NB compared to unmodified electrode. The developed NB sensor at Au-NPs modified electrode displays a wide linear response from 0.1 to 600 μM with high sensitivity of 1.01 μA μM −1 cm −2 and low limit of detection of 0.016 μM. The modified electrode shows exceptional selectivity in the presence of ions, phenolic and biologically coactive compounds. In addition, the Au-NPs modified electrode exhibits an outstanding recovery results toward NB in various real water samples

  17. Comparison of serum trace element levels in patients with or without pre-eclampsia

    Directory of Open Access Journals (Sweden)

    Leila Farzin

    2012-01-01

    Full Text Available Objective: In developing countries, nutritional deficiency of essential trace elements is a common health problem, particularly among pregnant women because of increased requirements of various nutrients. Accordingly, this study was initiated to compare trace elements status in women with or without pre-eclampsia. Materials and Methods: In this study, serum trace elements including zinc (Zn, selenium (Se, copper (Cu, calcium (Ca and magnesium (Mg were determined by using atomic absorption spectrometry (AAS in 60 patients and 60 healthy subjects. Results: There was no significant difference in the values of Cu between two groups (P > 0.05. A significant difference in Zn, Se, Ca and Mg levels were observed between patients with pre-eclampsia and control group (P 0.05. Conclusion: Our findings indicate that the levels of Zn, Se, Ca and Mg are significantly altered in pregnant women with pre-eclampsia. This research shows that these deficiencies can not due to hemodilution.

  18. The Graphene/l-Cysteine/Gold-Modified Electrode for the Differential Pulse Stripping Voltammetry Detection of Trace Levels of Cadmium

    OpenAIRE

    Yu Song; Chao Bian; Jianhua Tong; Yang Li; Shanghong Xia

    2016-01-01

    Cadmium(II) is a common water pollutant with high toxicity. It is of significant importance for detecting aqueous contaminants accurately, as these contaminants are harmful to human health and environment. This paper describes the fabrication, characterization, and application of an environment-friendly graphene (Gr)/l-cysteine/gold electrode to detect trace levels of cadmium (Cd) by differential pulse stripping voltammetry (DPSV). The influence of hydrogen overflow was decreased and the curr...

  19. Minor and trace metals levels in human milk in north western cities of Libya

    International Nuclear Information System (INIS)

    Mahabbis, M. T.; Elkubat, M. S.; Kut, H. M.

    2009-01-01

    Levels of twelve minor and trace metals were determined by using (AAS, ES and ICP/MS) in breast milk obtained from 60 women living in north western cities of Libya. Samples were collected at one week up to two years after delivery. Women with age>21 years old to an age of <43 years old were investigated. (Author)

  20. Galvanic detection of sulfur dioxide in ambient air at trace levels by anodic oxidation

    NARCIS (Netherlands)

    Lindqvist, F.

    1978-01-01

    A continuous method for the measurement of SO2 in ambient air at trace levels is described. The principle of detection is based on the anodic oxidation of SO2 in a galvanic cell. A differential measuring technique with a cell with two anodes and one cathode is used; background and noise current are

  1. Spectroscopic Determination of Trace Contaminants in High Purity Oxygen

    Science.gov (United States)

    Hornung, Steven D.

    2011-01-01

    Oxygen used for extravehicular activities (EVA) must be free of contaminants because a difference in a few tenths of a percent of argon or nitrogen content can mean significant reduction in available EVA time. These inert gases build up in the extravehicular mobility unit because they are not metabolized or scrubbed from the atmosphere. Measurement of oxygen purity above 99.5% is problematic, and currently only complex instruments such as gas chromatographs or mass spectrometers are used for these determinations. Because liquid oxygen boil-off from the space shuttle will no longer be available to supply oxygen for EVA use, other concepts are being developed to produce and validate high purity oxygen from cabin air aboard the International Space Station. A prototype optical emission technique capable of detecting argon and nitrogen below 0.1% in oxygen was developed at White Sands Test Facility. This instrument uses a glow discharge in reduced pressure gas to produce atomic emission from the species present. Because the atomic emission lines from oxygen, nitrogen, and argon are discrete and in many cases well-separated, trace amounts of argon and nitrogen can be detected in the ultraviolet and visible spectrum. This is a straightforward, direct measurement of the target contaminants and may lend itself to a device capable of on-orbit verification of oxygen purity. System design and optimized measurement parameters are presented.

  2. Quantification of trace-level DNA by real-time whole genome amplification.

    Science.gov (United States)

    Kang, Min-Jung; Yu, Hannah; Kim, Sook-Kyung; Park, Sang-Ryoul; Yang, Inchul

    2011-01-01

    Quantification of trace amounts of DNA is a challenge in analytical applications where the concentration of a target DNA is very low or only limited amounts of samples are available for analysis. PCR-based methods including real-time PCR are highly sensitive and widely used for quantification of low-level DNA samples. However, ordinary PCR methods require at least one copy of a specific gene sequence for amplification and may not work for a sub-genomic amount of DNA. We suggest a real-time whole genome amplification method adopting the degenerate oligonucleotide primed PCR (DOP-PCR) for quantification of sub-genomic amounts of DNA. This approach enabled quantification of sub-picogram amounts of DNA independently of their sequences. When the method was applied to the human placental DNA of which amount was accurately determined by inductively coupled plasma-optical emission spectroscopy (ICP-OES), an accurate and stable quantification capability for DNA samples ranging from 80 fg to 8 ng was obtained. In blind tests of laboratory-prepared DNA samples, measurement accuracies of 7.4%, -2.1%, and -13.9% with analytical precisions around 15% were achieved for 400-pg, 4-pg, and 400-fg DNA samples, respectively. A similar quantification capability was also observed for other DNA species from calf, E. coli, and lambda phage. Therefore, when provided with an appropriate standard DNA, the suggested real-time DOP-PCR method can be used as a universal method for quantification of trace amounts of DNA.

  3. The Determination Of Trace Element Levels In Diet By Neutron Activation Analysis

    International Nuclear Information System (INIS)

    Kukuh, Ratnawati; Djojosubroto, Harjoto

    2002-01-01

    Trace element levels in foodstuff are normally low. Although the levels are low, certain trace elements which are called essential trace elements have an important role in metabolism process. Deficiency or intoxication of essential trace elements may lead to abnormal health. In this study the levels of Zn, Fe, AI, Mn, and Co in diet samples were determined by neutron activation analysis, and then the daily intakes of these elements were estimated. The samples were prepared by duplicate diet method, representing those that were consumed by population from West, Central and East Java. Following the collection the respective samples were blended, then were freeze dried at-54 o c. The elemental quantification were performed by neutron activation analysis. The traceability of the determination was ensured using standard reference material NIST-SRM-1548a. The results show that the daily intake for Zn were 2.8-22.8 mg/day (reference value were 5- 40 mg/day), Fe were 3.1-26.5 mg/day (reference value were 6-40 mg/day), AI were 4,2-32.9 mg/day (reference value were 2-45 mg/day), Mn were 1.0-5,6 mg/day (reference value were 0.4-10,0 mg/day), and Co were 0,005-0,074 mg/day (reference value were 0.005 -1.8 mg/day

  4. Ultra-trace levels analysis of microcystins and nodularin in surface water by on-line solid-phase extraction with high-performance liquid chromatography tandem mass spectrometry.

    Science.gov (United States)

    Balest, Lydia; Murgolo, Sapia; Sciancalepore, Lucia; Montemurro, Patrizia; Abis, Pier Paolo; Pastore, Carlo; Mascolo, Giuseppe

    2016-06-01

    An on-line solid phase extraction coupled with high-performance liquid chromatography in tandem with mass spectrometry (on-line SPE/HPLC/MS-MS) method for the determination of five microcystins and nodularin in surface waters at submicrogram per liter concentrations has been optimized. Maximum recoveries were achieved by carefully optimizing the extraction sample volume, loading solvent, wash solvent, and pH of the sample. The developed method was also validated according to both UNI EN ISO IEC 17025 and UNICHIM guidelines. Specifically, ten analytical runs were performed at three different concentration levels using a reference mix solution containing the six analytes. The method was applied for monitoring the concentrations of microcystins and nodularin in real surface water during a sampling campaign of 9 months in which the ELISA method was used as standard official method. The results of the two methods were compared showing good agreement when the highest concentration values of MCs were found. Graphical abstract An on-line SPE/HPLC/MS-MS method for the determination of five microcystins and nodularin in surface waters at sub μg L(-1) was optimized and compared with ELISA assay method for real samples.

  5. Levels of aqueous humor trace elements in patients with open-angle glaucoma.

    Science.gov (United States)

    Hohberger, Bettina; Chaudhri, M Anwar; Michalke, Bernhard; Lucio, Marianna; Nowomiejska, Katarzyna; Schlötzer-Schrehardt, Ursula; Grieb, Pawel; Rejdak, Robert; Jünemann, Anselm G M

    2018-01-01

    Trace elements might play a role in the complex multifactorial pathogenesis of open-angle glaucoma. The aim of this study was to analyze concentrations of trace elements in aqueous humor samples of patients with primary open-angle glaucoma (POAG) and pseudoexfoliation glaucoma (PEXG). Thirty-three aqueous humor samples were obtained from patients undergoing cataract surgery: 12 patients with POAG (age 65.3±10.50, female 8, male 4), 10 patients with PEXG (age 65.9±11.27, female 6, male 4) and 11 patients without glaucoma (age 69.5±13.70, female 7, male 4) serving as controls. Aqueous humor levels of cadmium, iron, manganese, cobalt, copper and zinc were measured by Flow-Injection-Inductively-Coupled-Plasma-Mass-Spectrometry (FI-ICP-MS). From the statistical evaluation, we observed that patients with POAG had significantly higher aqueous humor levels of zinc (p=0.006) compared to controls. Increased aqueous humor levels of zinc were also observed in patients with PEXG in relation to control (p=0.0006). For iron we observed a significantly reduction in PEXG compared to control (p=0.002) and a significant difference between POAG and PEXG (p=0.0091). No significant differences were observed in aqueous humor levels of manganese, cobalt, copper, cadmium between glaucoma and control patients. No differences were seen for iron (POAG vs. controls). Analysis of trace element ratios was added. Significant differences in aqueous humor levels of zinc and iron between glaucoma and control patients support the hypothesis that these trace elements are involved in the pathogenesis of open-angle glaucoma. Copyright © 2017 Elsevier GmbH. All rights reserved.

  6. Estimation of trace levels of plutonium in urine samples by fission track technique

    International Nuclear Information System (INIS)

    Sawant, P.D.; Prabhu, S.; Pendharkar, K.A.; Kalsi, P.C.

    2009-01-01

    Individual monitoring of radiation workers handling Pu in various nuclear installations requires the detection of trace levels of plutonium in bioassay samples. It is necessary to develop methods that can detect urinary excretion of Pu in fraction of mBq range. Therefore, a sensitive method such as fission track analysis has been developed for the measurement of trace levels of Pu in bioassay samples. In this technique, chemically separated plutonium from the sample and a Pu standard were electrodeposited on planchettes and covered with Lexan solid state nuclear track detector (SSNTD) and irradiated with thermal neutrons in APSARA reactor of Bhabha Atomic Research Centre, India. The fission track densities in the Lexan films of the sample and the standard were used to calculate the amount of Pu in the sample. The minimum amount of Pu that can be analyzed by this method using doubly distilled electronic grade (E. G.) reagents is about 12 μBq/L. (author)

  7. Volatile organic compounds and trace metal level in some beers collected from Romanian market

    Science.gov (United States)

    Voica, Cezara; Kovacs, Melinda; Vadan, Marius

    2013-11-01

    Beer is one of the most popular beverages at worldwide level. Through this study fifteen different types of beer collected from Romanian market were analysed in order to evaluate their mineral, trace element as well the their organic content. Importance of such characterization of beer samples is supported by the fact that their chemical composition can affect both taste and stability of beer, as well the consumer health. Minerals and trace elements analysis were performed on ICP-MS while organic compounds analysis was done through GC-MS. Through ICP-MS analysis, elements as Ca, Na, K and Mg were evidenced at mgṡkg-1 order while elements as Cr, Ba, Co, Ni were detected at lower level. After GC-MS analysis the major volatile compounds that were detected belong to alcohols namely ethanol, propanol, isobutanol, isoamyl alcohol and linalool. Selected fatty acids and esters were evidenced also in the studied beer samples.

  8. Application of chronocoulomentry for trace levels uranium determination using catalytic nitrate reduction on mercury electrode

    International Nuclear Information System (INIS)

    Cantagallo, M.I.C.

    1988-01-01

    With the aim of improving the sensitivity of the electro-analytical determination of uranium at trace levels, the uranium catalyzed reduction of nitrate on mercury electrodes was used and the technique of chronocoulometry was compared with other voltammetric techniques. The catalytic process offers high sensitivity in comparison with uranyl reduction in absence of nitrate. The chronocoulometry, virtually unexplored for analytical applications, was found to be specially well suited for determinations based on this kind of electrode process, when using current integration times in the range of several seconds. Under these conditions the interference from diffusion controlled faradaic processes is reduced to a minimum. Several experimental parameters were investigated (eletrolyte composition, potential program, integration time, blank correction, temperature, previous separation) and adequate conditions were selected for the analytical determination of pure and real samples. The proposed method was applied and evaluated with real and, when necessary, an adapted liquid-liquid extraction procedure was used. Reference materials with complex matrices like rocks were first solubilized by hot digestion under pressure. The obtained results are in good agreement with the values obtained with other techniques such as X-ray fluorescence, mass spectrometry-isotope dilution and epithermal netron activation analysis. (author) [pt

  9. Levels of trace metals in water and sediment from Tyume River and ...

    African Journals Online (AJOL)

    Higher levels of Cd (0.038 ± 0.004 to 0.044 ± 0.003 mg/l) and Pb (0.021 ± 0.004 to 0.035 ± 0.001 mg/l) were found in the river water, which may be detrimental to the “health” of the aquatic ecosystem and the rural communities that utilise the river water for ... Key words: trace metals, water, sediment, farmland, Tyume River

  10. Trace level detection of explosives in solution using leidenfrost phenomenon assisted thermal desorption ambient mass spectrometry.

    Science.gov (United States)

    Saha, Subhrakanti; Mandal, Mridul Kanti; Chen, Lee Chuin; Ninomiya, Satoshi; Shida, Yasuo; Hiraoka, Kenzo

    2013-01-01

    The present paper demonstrates the detection of explosives in solution using thermal desorption technique at a temperature higher than Leidenfrost temperature of the solvent in combination with low temperature plasma (LTP) ionization. Leidenfrost temperature of a solvent is the temperature above which the solvent droplet starts levitation instead of splashing when placed on a hot metallic surface. During this desorption process, slow and gentle solvent evaporation takes place, which leads to the pre-concentration of less-volatile explosive molecules in the droplet and the explosive molecules are released at the last moment of droplet evaporation. The limits of detection for explosives studied by using this thermal desorption LTP ionization method varied in a range of 1 to 10 parts per billion (ppb) using a droplet volume of 20 μL (absolute sample amount 90-630 fmol). As LTP ionization method was applied and ion-molecule reactions took place in ambient atmosphere, various ion-molecule adduct species like [M+NO2](-), [M+NO3](-), [M+HCO3](-), [M+HCO4](-) were generated together with [M-H](-) peak. Each peak was unambiguously identified using 'Exactive Orbitrap' mass spectrometer in negative ionization mode within 3 ppm deviation compared to its exact mass. This newly developed technique was successfully applied to detect four explosives contained in the pond water and soil sample with minor sample pre-treatment and the explosives were detected with ppb levels. The present method is simple, rapid and can detect trace levels of explosives with high specificity from solutions.

  11. Simultaneous determination of niacin and pyridoxine at trace levels by using diode array high-performance liquid chromatography and liquid chromatography with quadrupole time-of-flight tandem mass spectrometry.

    Science.gov (United States)

    Sel, Sabriye; Öztürk Er, Elif; Bakırdere, Sezgin

    2017-12-01

    A highly sensitive and simple diode-array high-performance liquid chromatography and liquid chromatography with quadrupole time-of-flight tandem mass spectrometry method was developed for the simultaneous determination of niacin and pyridoxine in pharmaceutical drugs, tap water, and wastewater samples. To determine the in vivo behavior of niacin and pyridoxine, analytes were subjected to simulated gastric conditions. The calibration plots of the diode-array high-performance liquid chromatography and liquid chromatography with quadrupole time-of-flight tandem mass spectrometry method showed good linearity over a wide concentration range with close to 1.0 correlation coefficients for both analytes. The limit of detection/limit of quantitation values for liquid chromatography quadrupole time-of-flight tandem mass spectrometry analysis were 1.98/6.59 and 1.3/4.4 μg/L for niacin and pyridoxine, respectively, while limit of detection/limit of quantitation values for niacin and pyridoxine in high-performance liquid chromatography analysis were 3.7/12.3 and 5.7/18.9 μg/L, respectively. Recovery studies were also performed to show the applicability of the developed methods, and percentage recovery values were found to be 90-105% in tap water and 94-97% in wastewater for both analytes. The method was also successfully applied for the qualitative and quantitative determination of niacin and pyridoxine in drug samples. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  12. High fidelity analysis of BWR fuel assembly with COBRA-TF/PARCS and trace codes

    International Nuclear Information System (INIS)

    Abarca, A.; Miro, R.; Barrachina, T.; Verdu, G.; Soler, A.

    2013-01-01

    The growing importance of detailed reactor core and fuel assembly description for light water reactors (LWRs) as well as the sub-channel safety analysis requires high fidelity models and coupled neutronic/thermalhydraulic codes. Hand in hand with advances in the computer technology, the nuclear safety analysis is beginning to use a more detailed thermal hydraulics and neutronics. Previously, a PWR core and a 16 by 16 fuel assembly models were developed to test and validate our COBRA-TF/PARCS v2.7 (CTF/PARCS) coupled code. In this work, a comparison of the modeling and simulation advantages and disadvantages of modern 10 by 10 BWR fuel assembly with CTF/PARCS and TRACE codes has been done. The objective of the comparison is making known the main advantages of using the sub-channel codes to perform high resolution nuclear safety analysis. The sub-channel codes, like CTF, permits obtain accurate predictions, in two flow regime, of the thermalhydraulic parameters important to safety with high local resolution. The modeled BWR fuel assembly has 91 fuel rods (81 full length and 10 partial length fuel rods) and a big square central water rod. This assembly has been modeled with high level of detail with CTF code and using the BWR modeling parameters provided by TRACE. The same neutronic PARCS's model has been used for the simulation with both codes. To compare the codes a coupled steady state has be performed. (author)

  13. Levels of trace elements in medicinal plants with anti-diabetic potential

    International Nuclear Information System (INIS)

    Ray, D.K.; Jena, S.

    2014-01-01

    Medicinal plants with anti-diabetic potential have been characterized by Particle-Induced X-ray Emission (PIXE) technique. Trace elements such as Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, Rb, Sr and Pb are found to be present in these studied medicinal plant samples. The concentrations of elements like K and Ca are quantified in percentage level whereas other elements are found to be in parts per million levels. Elemental analysis of ten different medicinal plant samples commonly used for management and cure of diabetes, shows variation in concentrations. These elements either directly or indirectly may play some role to control diabetes. (author)

  14. The effects of low levels of dietary trace minerals on the plasma levels, faecal excretion health and performance of pigs in a hot African climate

    Directory of Open Access Journals (Sweden)

    M.H. Boma

    2009-09-01

    Full Text Available The present study was performed in order to evaluate the effects of lower than usual industry levels of dietary trace minerals on plasma levels, faecal excretion, performance, mortality and morbidity in growing-finishing pigs in a hot African climate. Group 1 (n =100 pigs received a diet with common industry levels of trace minerals. Group 2 (n =100 pigs received reduced dietary trace mineral levels but were fed the same basic diet as Group 1. Mortality, morbidity, pig performance and carcass measurements were evaluated. Two pigs in Group 1 and three pigs in Group 2 died. Thirteen pigs in Group 1 and 27 pigs in Group 2 were medically treated (P 0.05 by the dietary levels of these trace minerals. Plasma trace mineral concentrations were not affected by the dietary treatment.

  15. High-level-waste immobilization

    International Nuclear Information System (INIS)

    Crandall, J.L.

    1982-01-01

    Analysis of risks, environmental effects, process feasibility, and costs for disposal of immobilized high-level wastes in geologic repositories indicates that the disposal system safety has a low sensitivity to the choice of the waste disposal form

  16. Trace element levels in whole blood of riparian villagers of the Brazilian Amazon

    Energy Technology Data Exchange (ETDEWEB)

    Lisboa Rodrigues, Jairo; Lemos Batista, Bruno [Laboratorio de Toxicologia e Essencialidade de Metais, Depto. de Analises Clinicas, Toxicologicas e Bromatologicas, Faculdade de Ciencias Farmaceuticas de Ribeirao Preto-USP, Avenida do Cafe s/n, Monte Alegre, 14040-903, Ribeirao Preto-SP (Brazil); Fillion, Myriam [Centre interdisciplinaire de recherche sur la biologie, la sante, la societe et l' environnement (CINBIOSE), Universite du Quebec a Montreal (Canada); Passos, Carlos J.S. [Faculdade UnB Planaltina (FUP), Universidade de Brasilia, Planaltina (DF) (Brazil); Mergler, Donna [Centre interdisciplinaire de recherche sur la biologie, la sante, la societe et l' environnement (CINBIOSE), Universite du Quebec a Montreal (Canada); Barbosa, Fernando, E-mail: fbarbosa@fcfrp.usp.br [Laboratorio de Toxicologia e Essencialidade de Metais, Depto. de Analises Clinicas, Toxicologicas e Bromatologicas, Faculdade de Ciencias Farmaceuticas de Ribeirao Preto-USP, Avenida do Cafe s/n, Monte Alegre, 14040-903, Ribeirao Preto-SP (Brazil)

    2009-06-15

    Monitoring the nutritional status of essential elements is of critical importance in human health. However, trace element concentrations in biological fluids are affected by environmental and physiological parameters, and therefore considerable variations can occur between specific population subgroups. Brazil is a large country with much food diversity. Moreover, dietary habits differ from north to south. As an example, the traditional populations of the Brazilian Amazon basin are heavily dependent on fish, fruits, vegetables and manioc for their daily sustenance. However, very few studies have examined to what extent these diets reflect adequate nutritional status for essential elements. Then, in the present study we have evaluated the levels of some trace elements (Cu, Co, Zn Sr, and Rb) in the whole blood of a riparian Brazilian Amazonian population and estimated the influence of age and gender on levels and inter-element interactions in the same population. For this, 253 subjects, aged 15 to 87, from 13 communities situated on the banks of the Tapajos, one of the major tributaries of the Amazon, were randomly selected. The values found for cobalt, copper and strontium in whole blood are in the same range as in other populations. On the other hand, the levels of rubidium and zinc may be considered higher. Moreover, gender was shown to influence Zn and Cu levels while age influenced the concentrations of Sr and Rb in men and Cu in women. Given the scarcity of studies examining nutritional status in traditional communities of the Amazon, our study is the first to provide relevant insight into trace element values in this region and inter-element interactions. This paper is also of particular importance for future studies looking at the possible protective effects of traditional Amazon riparian diets against mercury intake from fish consumption.

  17. Trace element levels in whole blood of riparian villagers of the Brazilian Amazon

    International Nuclear Information System (INIS)

    Lisboa Rodrigues, Jairo; Lemos Batista, Bruno; Fillion, Myriam; Passos, Carlos J.S.; Mergler, Donna; Barbosa, Fernando

    2009-01-01

    Monitoring the nutritional status of essential elements is of critical importance in human health. However, trace element concentrations in biological fluids are affected by environmental and physiological parameters, and therefore considerable variations can occur between specific population subgroups. Brazil is a large country with much food diversity. Moreover, dietary habits differ from north to south. As an example, the traditional populations of the Brazilian Amazon basin are heavily dependent on fish, fruits, vegetables and manioc for their daily sustenance. However, very few studies have examined to what extent these diets reflect adequate nutritional status for essential elements. Then, in the present study we have evaluated the levels of some trace elements (Cu, Co, Zn Sr, and Rb) in the whole blood of a riparian Brazilian Amazonian population and estimated the influence of age and gender on levels and inter-element interactions in the same population. For this, 253 subjects, aged 15 to 87, from 13 communities situated on the banks of the Tapajos, one of the major tributaries of the Amazon, were randomly selected. The values found for cobalt, copper and strontium in whole blood are in the same range as in other populations. On the other hand, the levels of rubidium and zinc may be considered higher. Moreover, gender was shown to influence Zn and Cu levels while age influenced the concentrations of Sr and Rb in men and Cu in women. Given the scarcity of studies examining nutritional status in traditional communities of the Amazon, our study is the first to provide relevant insight into trace element values in this region and inter-element interactions. This paper is also of particular importance for future studies looking at the possible protective effects of traditional Amazon riparian diets against mercury intake from fish consumption.

  18. Metal-Organic Frameworks for Resonant-Gravimetric Detection of Trace-Level Xylene Molecules.

    Science.gov (United States)

    Xu, Tao; Xu, Pengcheng; Zheng, Dan; Yu, Haitao; Li, Xinxin

    2016-12-20

    As one of typical VOCs, xylene is seriously harmful to human health. Nowadays, however, there is really lack of portable sensing method to directly detect environmental xylene that has chemical inertness. Especially when the concentration of xylene is lower than the human olfactory threshold of 470 ppb, people are indeed hard to be aware of and avoid this harmful vapor. Herein the metal-organic framework (MOF) of HKUST-1 is first explored for sensing to the nonpolar molecule of p-xylene. And the sensing mechanism is identified that is via host-guest interaction of MOF with xylene molecule. By loading MOFs on mass-gravimetric resonant-cantilevers, sensing experiments for four MOFs of MOF-5, HKUST-1, ZIF-8, and MOF-177 approve that HKUST-1 has the highest sensitivity to p-xylene. The resonant-gravimetric sensing experiments with our HKUST-1 based sensors have demonstrated that trace-level p-xylene of 400 ppb can be detected that is lower than the human olfactory threshold of 470 ppb. We analyze that the specificity of HKUST-1 to xylene comes from Cu 2+ -induced moderate Lewis acidity and the "like dissolves like" interaction of the benzene ring. In situ diffuse reflectance infrared Fourier transform spectroscopy (DRIFTS) is used to elucidate the adsorbing/sensing mechanism of HKUST-1 to p-xylene, where p-xylene adsorbing induced blue-shift phenomenon is observed that confirms the sensing mechanism. Our study also indicates that the sensor shows good selectivity to various kinds of common interfering gases. And the long-term repeatability and stability of the sensing material are also approved for the usage/storage period of two months. This research approves that the MOF materials exhibit potential usages for high performance chemical sensors applications.

  19. The Graphene/l-Cysteine/Gold-Modified Electrode for the Differential Pulse Stripping Voltammetry Detection of Trace Levels of Cadmium

    Directory of Open Access Journals (Sweden)

    Yu Song

    2016-06-01

    Full Text Available Cadmium(II is a common water pollutant with high toxicity. It is of significant importance for detecting aqueous contaminants accurately, as these contaminants are harmful to human health and environment. This paper describes the fabrication, characterization, and application of an environment-friendly graphene (Gr/l-cysteine/gold electrode to detect trace levels of cadmium (Cd by differential pulse stripping voltammetry (DPSV. The influence of hydrogen overflow was decreased and the current response was enhanced because the modified graphene extended the potential range of the electrode. The Gr/l-cysteine/gold electrode showed high electrochemical conductivity, producing a marked increase in anodic peak currents (vs. the glass carbon electrode (GCE and boron-doped diamond (BDD electrode. The calculated detection limits are 1.15, 0.30, and 1.42 µg/L, and the sensitivities go up to 0.18, 21.69, and 152.0 nA·mm−2·µg−1·L for, respectively, the BDD electrode, the GCE, and the Gr/l-cysteine/gold electrode. It was shown that the Gr/l-cysteine/gold-modified electrode is an effective means for obtaining highly selective and sensitive electrodes to detect trace levels of cadmium.

  20. A radioagent method for determination of traces of phosphorus in high-purity silicon

    International Nuclear Information System (INIS)

    Chen, P.Y.; Chen, J.S.; Sun, H.J.; Yang, M.H.

    1985-01-01

    The feasibility of the determination of phosphorus at the extreme trace levels in high-purity silicon by radioreagent method is explored. After silicon dissolution with hydrofluoric and nitric acids and matrix volatilization, 12-molybdophosphoric acid is formed by the addition of the reagent, sup(99)MoOsub(4)sup(2-), in nitric acid medium and then extracted into isobutyl acetate. By plotting the phosphorus content against the radioactivity of sup(99)Mo in the organic phase, a linear relationship persisting down to 5 ng is obtained. Special effort was made to eliminate the unreacted sup(99)MoOsub(4)sup(2-) reagent and the optimal control of phosphorus blank introduced through the multistage analytical procedure in order to ensure reliable determination of phosphorus at the ppb level. (author)

  1. High Level Radioactive Waste Management

    International Nuclear Information System (INIS)

    1991-01-01

    The proceedings of the second annual international conference on High Level Radioactive Waste Management, held on April 28--May 3, 1991, Las Vegas, Nevada, provides information on the current technical issue related to international high level radioactive waste management activities and how they relate to society as a whole. Besides discussing such technical topics as the best form of the waste, the integrity of storage containers, design and construction of a repository, the broader social aspects of these issues are explored in papers on such subjects as conformance to regulations, transportation safety, and public education. By providing this wider perspective of high level radioactive waste management, it becomes apparent that the various disciplines involved in this field are interrelated and that they should work to integrate their waste management activities. Individual records are processed separately for the data bases

  2. High-level Petri Nets

    DEFF Research Database (Denmark)

    various journals and collections. As a result, much of this knowledge is not readily available to people who may be interested in using high-level nets. Within the Petri net community this problem has been discussed many times, and as an outcome this book has been compiled. The book contains reprints...... of some of the most important papers on the application and theory of high-level Petri nets. In this way it makes the relevant literature more available. It is our hope that the book will be a useful source of information and that, e.g., it can be used in the organization of Petri net courses. To make......High-level Petri nets are now widely used in both theoretical analysis and practical modelling of concurrent systems. The main reason for the success of this class of net models is that they make it possible to obtain much more succinct and manageable descriptions than can be obtained by means...

  3. Trace levels of innate immune response modulating impurities (IIRMIs) synergize to break tolerance to therapeutic proteins.

    Science.gov (United States)

    Verthelyi, Daniela; Wang, Vivian

    2010-12-22

    Therapeutic proteins such as monoclonal antibodies, replacement enzymes and toxins have significantly improved the therapeutic options for multiple diseases, including cancer and inflammatory diseases as well as enzyme deficiencies and inborn errors of metabolism. However, immune responses to these products are frequent and can seriously impact their safety and efficacy. Of the many factors that can impact protein immunogenicity, this study focuses on the role of innate immune response modulating impurities (IIRMIs) that could be present despite product purification and whether these impurities can synergize to facilitate an immunogenic response to therapeutic proteins. Using lipopolysaccharide (LPS) and CpG ODN as IIRMIs we showed that trace levels of these impurities synergized to induce IgM, IFNγ, TNFα and IL-6 expression. In vivo, trace levels of these impurities synergized to increase antigen-specific IgG antibodies to ovalbumin. Further, whereas mice treated with human erythropoietin showed a transient increase in hematocrit, those that received human erythropoietin containing low levels of IIRMIs had reduced response to erythropoietin after the 1(st) dose and developed long-lasting anemia following subsequent doses. This suggests that the presence of IIRMIs facilitated a breach in tolerance to the endogenous mouse erythropoietin. Overall, these studies indicate that the risk of enhancing immunogenicity should be considered when establishing acceptance limits of IIRMIs for therapeutic proteins.

  4. Trace levels of innate immune response modulating impurities (IIRMIs synergize to break tolerance to therapeutic proteins.

    Directory of Open Access Journals (Sweden)

    Daniela Verthelyi

    Full Text Available Therapeutic proteins such as monoclonal antibodies, replacement enzymes and toxins have significantly improved the therapeutic options for multiple diseases, including cancer and inflammatory diseases as well as enzyme deficiencies and inborn errors of metabolism. However, immune responses to these products are frequent and can seriously impact their safety and efficacy. Of the many factors that can impact protein immunogenicity, this study focuses on the role of innate immune response modulating impurities (IIRMIs that could be present despite product purification and whether these impurities can synergize to facilitate an immunogenic response to therapeutic proteins. Using lipopolysaccharide (LPS and CpG ODN as IIRMIs we showed that trace levels of these impurities synergized to induce IgM, IFNγ, TNFα and IL-6 expression. In vivo, trace levels of these impurities synergized to increase antigen-specific IgG antibodies to ovalbumin. Further, whereas mice treated with human erythropoietin showed a transient increase in hematocrit, those that received human erythropoietin containing low levels of IIRMIs had reduced response to erythropoietin after the 1(st dose and developed long-lasting anemia following subsequent doses. This suggests that the presence of IIRMIs facilitated a breach in tolerance to the endogenous mouse erythropoietin. Overall, these studies indicate that the risk of enhancing immunogenicity should be considered when establishing acceptance limits of IIRMIs for therapeutic proteins.

  5. Effect of kombucha on some trace element levels in different organs of electromagnetic field exposed rats

    Directory of Open Access Journals (Sweden)

    Ola A. Gharib

    2014-01-01

    Full Text Available Mobile phones have increased exponentially all over the world. The present study was performed to evaluate the effect of kombucha (KT on some trace element levels of brain, spleen and intestine in male albino rats exposed to a 950 MHz electromagnetic field (EMF. Four experimental groups labelled as controls, EMF group, KT group and KT + EMF group were formed with six randomly chosen animals in each group. After EMF exposure for eight weeks and the animals were sacrificed by decapitation. Brain, spleen and intestine samples were collected for trace element analysis. The group of animals subjected to electromagnetic waves caused significant increases in iron copper levels and copper/zinc ratio accompanied with a decrease of zinc level in all studied organs. Combined treatment of kombucha with EMF resulted in a successful attenuation of these adverse effects of EMF. From present findings we can state that kombucha as a supplement has an ameliorative signs against the effects of electromagnetic radiation.

  6. High-Level Radioactive Waste.

    Science.gov (United States)

    Hayden, Howard C.

    1995-01-01

    Presents a method to calculate the amount of high-level radioactive waste by taking into consideration the following factors: the fission process that yields the waste, identification of the waste, the energy required to run a 1-GWe plant for one year, and the uranium mass required to produce that energy. Briefly discusses waste disposal and…

  7. High-level radioactive wastes

    International Nuclear Information System (INIS)

    Grissom, M.C.

    1982-10-01

    This bibliography contains 812 citations on high-level radioactive wastes included in the Department of Energy's Energy Data Base from January 1981 through July 1982. These citations are to research reports, journal articles, books, patents, theses, and conference papers from worldwide sources. Five indexes are provided: Corporate Author, Personal Author, Subject, Contract Number, and Report Number

  8. Trace elements in migrating high-temperature fluids: Effects of diffusive exchange with the adjoining solid

    Science.gov (United States)

    Kenyon, Patricia M.

    1993-01-01

    Trace element concentrations and isotopic ratios are frequently used to study the behavior of high-temperature fluids in both metamorphic and igneous systems. Many theoretical formulations of the effects of fluid migration on trace elements have assumed instantaneous reequilibration between the migrating fluid and the solid material through which it is passing. This paper investigates the additional effects which arise when equilibration is not instantaneous due to a limited rate of diffusion in the solid, using an analytical steady state solution to a set of partial differential equations describing the exchange of trace elements between the fluid and the solid during the migration of the fluid.

  9. Levels of essential and potentially toxic trace metals in Antarctic macro algae

    International Nuclear Information System (INIS)

    Farias, Silvia; Arisnabarreta, Sebastian Perez; Vodopivez, Cristian; Smichowski, Patricia

    2002-01-01

    Eleven species of Antarctic algae were examined for their accumulation ability in the uptake of different metals and metalloids from the Antarctic aquatic environment. Macro algae were collected during the 2000 austral summer season at Jubany Station (Argentinean base) around Potter Cove, King George Island. The elements quantified were: As, Cd, Co, Cr, Cu, Fe, Mn, Mo, Ni, Pb, Se, Sr, V, and Zn. An optimized microwave-assisted digestion procedure was used to digest the samples and the elements were determined by inductively coupled plasma optical emission spectrometry. A wide range of metal retention capacity among the different species was observed. The highest levels of trace elements were found in Monostroma hariotii and Phaeurus antarcticus, with concentrations up to 3095 μg g -1 for Fe. On the basis of the levels of trace elements observed in Monostroma hariotii and its wide distribution in the Antarctic Peninsula, this organism accomplishes a number of prerequisites to be considered as an adequate biomonitor for future studies

  10. High performance dosimetry calculations using adapted ray-tracing

    International Nuclear Information System (INIS)

    Perrotte, Lancelot; Saupin, Guillaume

    2010-01-01

    When preparing interventions on nuclear sites, it is interesting to study different scenarios, to identify the most appropriate one for the operator(s). Using virtual reality tools is a good way to simulate the potential scenarios. Thus, taking advantage of very efficient computation times can help the user studying different complex scenarios, by immediately evaluating the impact of any changes. In the field of radiation protection, people often use computation codes based on the straight line attenuation method with build-up factors. As for other approaches, geometrical computations (finding all the interactions between radiation rays and the scene objects) remain the bottleneck of the simulation. We present in this paper several optimizations used to speed up these geometrical computations, using innovative GPU ray-tracing algorithms. For instance, we manage to compute every intersection between 600 000 rays and a huge 3D industrial scene in a fraction of second. Moreover, our algorithm works the same way for both static and dynamic scenes, allowing easier study of complex intervention scenarios (where everything moves: the operator(s), the shielding objects, the radiation sources).

  11. The Effect of Helicobacter pylori Eradication on the Levels of Essential Trace Elements

    Directory of Open Access Journals (Sweden)

    Meng-Chieh Wu

    2014-01-01

    Full Text Available Objective. This study was designed to compare the effect of Helicobacter pylori (H. pylori infection treatment on serum zinc, copper, and selenium levels. Patients and Methods. We measured the serum zinc, copper, and selenium levels in H. pylori-positive and H. pylori-negative patients. We also evaluated the serum levels of these trace elements after H. pylori eradication. These serum copper, zinc, and selenium levels were determined by inductively coupled plasma mass spectrometry. Results. Sixty-three H. pylori-positive patients and thirty H. pylori-negative patients were studied. Serum copper, zinc, and selenium levels had no significant difference between H. pylori-positive and H. pylori-negative groups. There were 49 patients with successful H. pylori eradication. The serum selenium levels were lower after successful H. pylori eradication, but not significantly (P=0.06. There were 14 patients with failed H. pylori eradication. In this failed group, the serum selenium level after H. pylori eradication therapy was significantly lower than that before H. pylori eradication therapy (P<0.05. The serum zinc and copper levels had no significant difference between before and after H. pylori eradication therapies. Conclusion. H pylori eradication regimen appears to influence the serum selenium concentration (IRB number: KMUH-IRB-20120327.

  12. RPython high-level synthesis

    Science.gov (United States)

    Cieszewski, Radoslaw; Linczuk, Maciej

    2016-09-01

    The development of FPGA technology and the increasing complexity of applications in recent decades have forced compilers to move to higher abstraction levels. Compilers interprets an algorithmic description of a desired behavior written in High-Level Languages (HLLs) and translate it to Hardware Description Languages (HDLs). This paper presents a RPython based High-Level synthesis (HLS) compiler. The compiler get the configuration parameters and map RPython program to VHDL. Then, VHDL code can be used to program FPGA chips. In comparison of other technologies usage, FPGAs have the potential to achieve far greater performance than software as a result of omitting the fetch-decode-execute operations of General Purpose Processors (GPUs), and introduce more parallel computation. This can be exploited by utilizing many resources at the same time. Creating parallel algorithms computed with FPGAs in pure HDL is difficult and time consuming. Implementation time can be greatly reduced with High-Level Synthesis compiler. This article describes design methodologies and tools, implementation and first results of created VHDL backend for RPython compiler.

  13. Spectroscopic Determination of Trace Contaminants in High-Purity Oxygen

    Science.gov (United States)

    Hornung, Steven

    2013-01-01

    Oxygen used for extravehicular activities (EVAs) must be free of contaminants because a difference in a few tenths of a percent of argon or nitrogen content can mean significant reduction in available EVA time. These inert gases build up in the extravehicular mobility unit because they are not metabolized or scrubbed from the atmosphere. A prototype optical emission technique capable of detecting argon and nitrogen below 0.1% in oxygen has been developed. This instrument uses a glow discharge in reduced-pressure gas to produce atomic emission from the species present. Because the atomic emission lines from oxygen, nitrogen, and argon are discrete, and in many cases well-separated, trace amounts of argon and nitrogen can be detected in the ultraviolet and visible spectrum. This is a straightforward, direct measurement of the target contaminants, and may lend itself to a device capable of on-orbit verification of oxygen purity. A glow discharge is a plasma formed in a low-pressure (1 to 10 Torr) gas cell between two electrodes. Depending on the configuration, voltages ranging from 200 V and above are required to sustain the discharge. In the discharge region, the gas is ionized and a certain population is in the excited state. Light is produced by the transitions from the excited states formed in the plasma to the ground state. The spectrum consists of discrete, narrow emission lines for the atomic species, and broader peaks that may appear as a manifold for molecular species such as O2 and N2, the wavelengths and intensities of which are a characteristic of each atom. The oxygen emission is dominated by two peaks at 777 and 844 nm.

  14. Blood lead: Its effect on trace element levels and iron structure in hemoglobin

    International Nuclear Information System (INIS)

    Jin, C.; Li, Y.; Li, Y.L.; Zou, Y.; Zhang, G.L.; Normura, M.; Zhu, G.Y.

    2008-01-01

    Lead is a ubiquitous environmental pollutant that induce a broad range of physiological and biochemical dysfunctions. The purpose of this study was to investigate its effects on trace elements and the iron structure in hemoglobin. Blood samples were collected from rats that had been exposed to lead. The concentration of trace elements in whole blood and blood plasma was determined by ICP-MS and the results indicate that lead exists mainly in the red blood cells and only about 1-3% in the blood plasma. Following lead exposure, the concentrations of zinc and iron in blood decrease, as does the hemoglobin level. This indicates that the heme biosynthetic pathway is inhibited by lead toxicity and that lead poisoning-associated anemia occurs. The selenium concentration also decreases after lead exposure, which may lead to an increased rate of free radical production. The effect of lead in the blood on iron structure in hemoglobin was determined by EXAFS. After lead exposure, the Fe-O bond length increases by about 0.07 A and the Fe-Np bond length slightly increases, but the Fe-N ε bond length remains unchanged. This indicates that the blood content of Hb increases, but that the content of HbO 2 decreases

  15. Levels of trace metals in soil and vegetation along major and minor ...

    African Journals Online (AJOL)

    ... emission couple with waste dispose along the roads remain a threat. The findings in general indicate the levels of metals in soil and plant samples were within the EU limits with the exception of Cd. In addition, the high level of Cd appears to reach pollution levels and metal dynamics up the food chain is highly possible.

  16. Graphene–platinum nanocomposite as a sensitive and selective voltammetric sensor for trace level arsenic quantification

    Directory of Open Access Journals (Sweden)

    R. Kempegowda

    2014-01-01

    Full Text Available A simple protocol for the chemical modification of graphene with platinum nanoparticles and its subsequent electroanalytical application toward sensitive and selective determination of arsenic has been described. Chemical modification was carried out by the simultaneous and sequential chemical reduction of graphene oxide and hexachloroplatinic acid in the presence of ethylene glycol as a mild reducing agent. The synthesized graphene–platinum nanocomposite (Gr–nPt has been characterized through infrared spectroscopy, x-ray diffraction study, field emission scanning electron microscopy and cyclic voltammetry (CV techniques. CV and square-wave anodic stripping voltammetry have been used to quantify arsenic. The proposed nanostructure showed linearity in the concentration range 10–100 nM with a detection limit of 1.1 nM. The proposed sensor has been successfully applied to measure trace levels of arsenic present in natural sample matrices like borewell water, polluted lake water, agricultural soil, tomato and spinach leaves.

  17. Separation Techniques for Uranium and Plutonium at Trace Levels for the Thermal Ionization Mass Spectrometric Determination

    International Nuclear Information System (INIS)

    Suh, M. Y.; Han, S. H.; Kim, J. G.; Park, Y. J.; Kim, W. H.

    2005-12-01

    This report describes the state of the art and the progress of the chemical separation and purification techniques required for the thermal ionization mass spectrometric determination of uranium and plutonium in environmental samples at trace or ultratrace levels. Various techniques, such as precipitation, solvent extraction, extraction chromatography, and ion exchange chromatography, for separation of uranium and plutonium were evaluated. Sample preparation methods and dissolution techniques for environmental samples were also discussed. Especially, both extraction chromatographic and anion exchange chromatographic procedures for uranium and plutonium in environmental samples, such as soil, sediment, plant, seawater, urine, and bone ash were reviewed in detail in order to propose some suitable methods for the separation and purification of uranium and plutonium from the safeguards environmental or swipe samples. A survey of the IAEA strengthened safeguards system, the clean room facility of IAEA's NWAL(Network of Analytical Laboratories), and the analytical techniques for safeguards environmental samples was also discussed here

  18. Separation Techniques for Uranium and Plutonium at Trace Levels for the Thermal Ionization Mass Spectrometric Determination

    Energy Technology Data Exchange (ETDEWEB)

    Suh, M. Y.; Han, S. H.; Kim, J. G.; Park, Y. J.; Kim, W. H

    2005-12-15

    This report describes the state of the art and the progress of the chemical separation and purification techniques required for the thermal ionization mass spectrometric determination of uranium and plutonium in environmental samples at trace or ultratrace levels. Various techniques, such as precipitation, solvent extraction, extraction chromatography, and ion exchange chromatography, for separation of uranium and plutonium were evaluated. Sample preparation methods and dissolution techniques for environmental samples were also discussed. Especially, both extraction chromatographic and anion exchange chromatographic procedures for uranium and plutonium in environmental samples, such as soil, sediment, plant, seawater, urine, and bone ash were reviewed in detail in order to propose some suitable methods for the separation and purification of uranium and plutonium from the safeguards environmental or swipe samples. A survey of the IAEA strengthened safeguards system, the clean room facility of IAEA's NWAL(Network of Analytical Laboratories), and the analytical techniques for safeguards environmental samples was also discussed here.

  19. Speciation of the plutonium at trace levels by capillary electrophoresis-ICP-MS coupling

    International Nuclear Information System (INIS)

    Ambard, Ch.

    2007-01-01

    The CE-ICP-MS coupling allowed the development of new analytical methods for the study of plutonium (Pu) speciation at trace levels including complexation studies of this element by organic and inorganic ligands. First, a method, called dual detection, based on the simultaneous use of the UV-Visible spectrophotometer integrated in the capillary electrophoresis and the ICP-MS was developed and validated. It allows the unambiguous determination of electrophoretic mobilities for separated chemical species and gives a powerful tool for speciation studies. Then, the influence on Pu redox speciation of the buffer from the background electrolyte was evaluated. This study showed the implications of the electrolyte constituents' choice on Pu redox equilibrium in the sample. Furthermore, the CE-ICP-MS coupling was used for studying the Pu complexation at trace levels by some organic (NTA and DTPA) and inorganic ligands (carbonates). The behaviour of Pu valence +III, +IV and +VI was studied in the presence of buffer at near neutral pH. Different species of Pu were observed depending on the initial oxidation state of the plutonium. The study showed the potential of poly-amino-carboxylic acids, such as NTA and DTPA, for dissolving Pu precipitates, regardless its initial speciation. Finally, the carbonation of pentavalent neptunium, as an analogue of Pu(V), was achieved at very low concentration of Np (10 -8 mol.L -1 ). The formation of NpO 2 (CO 3 ) - at 25 C and 2,5*10 -2 mol.L -1 ionic strength was measured by CE-ICP-MS and found to consistent with literature data. (author)

  20. Speciation of the plutonium at trace levels by capillary electrophoresis-ICP-MS coupling

    International Nuclear Information System (INIS)

    Ambard, Ch.

    2007-01-01

    The CE-ICP-MS coupling allowed the development of new analytical methods for the study of plutonium speciation at trace levels including complexation studies of this element by organic and inorganic ligands. First, a method, called dual detection, based on the simultaneous use of the UV-Visible spectrophotometer integrated in the capillary electrophoresis and the ICPMS was developed and validated. It allows the unambiguous determination of electrophoretic mobilities for separated chemical species and gives a powerful tool for speciation studies. Then, the influence on plutonium redox speciation of the buffer from the background electrolyte was evaluated. This study showed the implications of the electrolyte constituents' choice on plutonium redox equilibrium in the sample. Furthermore, the CE-ICP-MS coupling was used for studying the plutonium complexation at trace levels by some organic (NTA and DTPA) and inorganic ligands (carbonates). The behaviour of plutonium valence +III, +IV and +VI was studied in the presence of buffer at near neutral pH. Different species of plutonium were observed depending on the initial oxidation state of the plutonium. This study showed the potential of poly-amino-carboxylic acids, such as NTA and DTPA, for dissolving plutonium precipitates, regardless its initial speciation. Finally, the carbonation of pentavalent neptunium, as an analogue of Pu(V), was achieved at very low concentration of Np (10 -8 mol.L -1 ). The formation constant of NpO 2 (CO 3 )- at 25 deg. C and 2,5 x 10 -2 mol.L -1 ionic strength was measured by CE-ICP-MS and found to be consistent with literature data. (author)

  1. Selected trace metal levels in common vegetables grown in NWFP, Pakistan

    International Nuclear Information System (INIS)

    Masud, K.; Jaffar, M.

    1998-01-01

    Seventeen vegetables procured from local markets of Peshawar and its suburbs were analyzed using wet digestion atomic absorption method for Fe, Pb, As, Hg, Cd, Cr, and Ni. The families investigated were: Cucurbitaceae, Solanaceae, Cruciferae, Liliaceae, Araceae, Leguminosae, Malvaceae, Umbelliferae and Zingiberaceae. The heavy metal data are reported at 99%(- + 2S) confidence level for triplicate measurements on sub samples of a given sample with an overall reproducibility of 2% compared with standard material samples. Comparison of averages through t-test indicates that each vegetable group is distinctly different from the other in terms of metal content. Maximum iron was present in garlic, at 4.585 mu g/g, dry weight (edible part-stem) of the Liliacease family. Arsenic was found to be below detection limit in all the vegetable groups. Lead levels were quite low, maximum concentration (0.0200 mu g/g, dry weight) was found in karaila (edible part-fruit). Mercury levels were relatively higher, with maximum concentration (2.590 mu g/g, dry weight) in gem (edible part-stem). The levels of nickel were moderately higher, being maximum (2.375 mu g/g dry weight) in karaila. The overall content of trace metals appeared to be within laid down internationally for safe human consumption, with only a few exceptions. (author)

  2. High-efficiency photorealistic computer-generated holograms based on the backward ray-tracing technique

    Science.gov (United States)

    Wang, Yuan; Chen, Zhidong; Sang, Xinzhu; Li, Hui; Zhao, Linmin

    2018-03-01

    Holographic displays can provide the complete optical wave field of a three-dimensional (3D) scene, including the depth perception. However, it often takes a long computation time to produce traditional computer-generated holograms (CGHs) without more complex and photorealistic rendering. The backward ray-tracing technique is able to render photorealistic high-quality images, which noticeably reduce the computation time achieved from the high-degree parallelism. Here, a high-efficiency photorealistic computer-generated hologram method is presented based on the ray-tracing technique. Rays are parallelly launched and traced under different illuminations and circumstances. Experimental results demonstrate the effectiveness of the proposed method. Compared with the traditional point cloud CGH, the computation time is decreased to 24 s to reconstruct a 3D object of 100 ×100 rays with continuous depth change.

  3. SRXRF study of trace elements in hippocampus of pup rats after prenatal and postnatal exposure to low-level mercury

    International Nuclear Information System (INIS)

    Zhang Fang; Feng Weiyue; Chai Zhifang; Wang Meng; Shi Junwen; Huang Yuying; He Wei

    2005-01-01

    Since the pollution of mercury in the environment still keeps high, more and more concerns over mercury toxicity are focused on the potential risk associated with relatively low-dose and long-term mercury exposure in the environment. It is well known that fetus and developing children are the susceptive victims of mercury damage. Therefore, high attention is focused on whether the prenatal and postnatal exposure to relatively low level of mercury will be harmful to children development. Some epidemiological studies reported that the methylmercury-related neuropsychological deficits were mainly found in the domains of cognitional parts, such as language, attention, memory, and so forth, Our previous study found out that high level of mercury was accumulated in the pup hippocampus after their prenatal and postnatal exposure to low dose of inorganic mercury. Synchrotron radiation X-ray fluorescence technique (SRXRF) is characterized of its simultaneous determination of multi-elements, high sensitivity, small sampling amount and microanalysis. SRXRF does not cause the damage of irradiated samples. Thus, it makes possible to measure the distributions of trace elements in a selected area. In this study, in order to study the effects of low-level mercury exposure to pup rat brain, some oxidation-related elements, e.g. Cu, Fe and Mn in pup hippocampus after in utero and weaning exposure to low-level inorganic mercury were determined by SRXRF. The experiment was performed at a synchrotron radiation facility at Institute of High Energy Physics. And the spot size of the beam irradiating on the sample was adjusted to about 100 x 200 μm 2 , Each spot was irradiated for about 100 s. The spectra were analyzed by the AXIL program. Additionally, the activities of some important antioxidant enzymes, such as GSH-Px, SOD, CAT, were also measured together with the content of malondialdehyde (MDA). The results showed that mercury exposure could lead to significant increase of both

  4. The Effect of Smoking on the Serum Level of Some Trace Elements in Pregnant Women

    International Nuclear Information System (INIS)

    El-Ghetany, SH.M.; Ahmad, M.H.; Marei, E.S.; Ashrey, H. A.

    2005-01-01

    Maternal smoking during pregnancy is a cause of many adverse outcomes, not only during fetal life, but may also extend to childhood and even early adulthood. This study was designed to evaluate the effect of tobacco smoking on some trace elements on pregnant mothers who smoke and their newborns. The study was carried out on 150 pregnant women and their newborns; fifty smokers (group I), fifty passive smoker subjects (group II) and 50 non-smokers served as controls (group III). Their neonates were also categorized into three groups accordingly. Maternal urine cotinine was determined by radioimmunoassay as an indicator for the degree of influence of smoking, it confirmed a significant elevation among groups I and II. The serum levels of zinc (Zn), selenium (Se), copper (Cu), cadmium (Cd), manganese (Mn) and magnesium (Mg) were measured in the serum of pregnant mothers and the cord serum of their newborns by atomic absorption spectrophotometer. This study demonstrated significant lower concentrations of serum Zn and Se in group I and II and their newborns when compared to the control group and control newborns. Significant increases in serum Cd and Cu were observed in-group I and II and their neonates versus the controls. As regards Mn and Mg no significant difference was established between the three studied groups. Our results suggested that tobacco smoking had definite effect on some trace elements that absolutely had drawbacks on both pregnant mothers and their babies. Tobacco smoke contains many toxic, mutagenic and teratogenic substances. Several epidemiological studies illustrated that cigarette smoking among females during the reproductive period have a direct insult on the nutritional and health status of their babies (Jauniaux et al, 1999). Cigarette smoking

  5. Determination of trace impurities in high-purity iron using salting-out of polyoxyethylene-type surfactants

    Energy Technology Data Exchange (ETDEWEB)

    Matsumiya, Hiroaki, E-mail: h-matsu@numse.nagoya-u.ac.jp [Department of Molecular Design and Engineering, Graduate School of Engineering, Nagoya University, Furo-cho, Chikusa-ku, Nagoya 464-8603 (Japan); Sakane, Yuto; Hiraide, Masataka [Department of Molecular Design and Engineering, Graduate School of Engineering, Nagoya University, Furo-cho, Chikusa-ku, Nagoya 464-8603 (Japan)

    2009-10-19

    To an iron sample solution was added polyoxyethylene-4-isononylphenoxy ether (PONPE, nonionic surfactant, average number of ethylene oxides 7.5) and the surfactant was aggregated by the addition of lithium chloride. The iron(III) matrix was collected into the condensed surfactant phase in >99.9% yields, leaving trace metals [e.g., Ti(IV), Cr(III), Mn(II), Co(II), Ni(II), Cu(II), Zn(II), Cd(II), Pb(II), and Bi(III)] in the aqueous phase. After removing the surfactant phase by centrifugation, the remaining trace metals were concentrated onto an iminodiacetic acid-type chelating resin. The trace metals were desorbed with dilute nitric acid for the determination by inductively coupled plasma-mass spectrometry or graphite-furnace atomic absorption spectrometry. The proposed separation method allowed the analysis of high-purity iron metals for trace impurities at low {mu}g g{sup -1} to ng g{sup -1} levels.

  6. Highly Sensitive Filter Paper Substrate for SERS Trace Explosives Detection

    Directory of Open Access Journals (Sweden)

    Pedro M. Fierro-Mercado

    2012-01-01

    Full Text Available We report on a novel and extremely low-cost surface-enhanced Raman spectroscopy (SERS substrate fabricated depositing gold nanoparticles on common lab filter paper using thermal inkjet technology. The paper-based substrate combines all advantages of other plasmonic structures fabricated by more elaborate techniques with the dynamic flexibility given by the inherent nature of the paper for an efficient sample collection, robustness, and stability. We describe the fabrication, characterization, and SERS activity of our substrate using 2,4,6-trinitrotoluene, 2,4-dinitrotoluene, and 1,3,5-trinitrobenzene as analytes. The paper-based SERS substrates presented a high sensitivity and excellent reproducibility for analytes employed, demonstrating a direct application in forensic science and homeland security.

  7. Removing high-level contaminants

    International Nuclear Information System (INIS)

    Wallace, Paula

    2013-01-01

    Full text: Using biomimicry, an Australian cleantech innovation making inroads intoChinas's industrial sector offers multiple benefits to miners and processors in Australia. Stephen Shelley, the executive chairman of Creative Water Technology (CWT), was on hand at a recent trade show to explain how his Melbourne company has developed world-class techniques in zero liquid discharge and fractional crystallization of minerals to apply to a wide range of water treatment and recycling applications. “Most existing technologies operate with high energy distillation, filters or biological processing. CWT's appliance uses a low temperature, thermal distillation process known as adiabatic recovery to desalinate, dewater and/or recycle highly saline and highly contaminated waste water,” said Shelley. The technology has been specifically designed to handle the high levels of contaminant that alternative technologies struggle to process, with proven water quality results for feed water samples with TDS levels over 300,000ppm converted to clean water with less than 20ppm. Comparatively, reverse osmosis struggles to process contaminant levels over 70,000ppm effectively. “CWT is able to reclaim up to 97% clean usable water and up to 100% of the contaminants contained in the feed water,” said Shelley, adding that soluble and insoluble contaminants are separately extracted and dried for sale or re-use. In industrial applications CWT has successfully processed feed water with contaminant levels over 650,000 mg/1- without the use of chemicals. “The technology would be suitable for companies in oil exploration and production, mining, smelting, biofuels, textiles and the agricultural and food production sectors,” said Shelley. When compared to a conventional desalination plant, the CWT system is able to capture the value in the brine that most plants discard, not only from the salt but the additional water it contains. “If you recover those two commodities... then you

  8. Analysis of traces at ORNL's new high-flux neutron activation laboratory

    International Nuclear Information System (INIS)

    Ricci, E.; Handley, T.H.; Dyer, F.F.

    1974-01-01

    The investigations are outlined, which are carried out in order to develop (preferably instrumental) methods for multielement analysis of various trace elements. For this reason a new High-Flux NAA Laboratory was constructed at ORNL's. A general review is given on the Laboratory, further some methods and applications are shown. In the field of comparator activation analysis comparative data are given on mercury determinations in various matrices, and on arsenic determination in grasshoppers. This later method was used to trace the transport of arsenic containing pesticides. Some data are given on absolute activation analysis of Na, Ci, Mn, Br, and Au, too. (K.A.)

  9. Determination of trace elements in Ethiopian, Vietnamese, and Japanese women using high-resolution IC-PMS.

    Science.gov (United States)

    Tekeste, Zinaye; Amare, Bemnet; Asfaw, Fanaye; Fantahun, Bereket; van Nguyen, Nhien; Nishikawa, Takeshi; Yabutani, Tomoki; Okayasu, Takako; Ota, Fusao; Kassu, Afework

    2015-10-01

    Humans and other living organisms require small quantities of trace elements throughout life. Both insufficient and excessive intakes of trace elements can have negative consequences. However, there is little information on serum level of trace elements in different populations. This study examines serum levels of trace elements in Ethiopian, Japanese, and Vietnamese women. Random samples of healthy women who were referred for routine hospital laboratory examinations in the cities of Hanoi, Sapporo, and Gondar were invited to participate in the study. Serum levels of magnesium, zinc, copper, iron, selenium, and calcium were determined using an inductively coupled plasma mass spectrometer. Furthermore, body mass index of each study participant was determined. The mean ± SD serum concentrations of zinc (μg/dL), copper (μg/dL), iron (μg/dL), selenium (μg/dL) and calcium (mg/dL), respectively, were 76.51 ± 39.16, 152.20 ± 55.37, 385.68 ± 217.95, 9.15 ± 4.21, and 14.18 ± 3.91 in Ethiopian women; 111.49 ± 52.92, 105.86 ± 26.02, 155.09 ± 94.83, 14.11 ± 3.41, and 11.66 ± 2.51 in Vietnamese women; and 60.69 ± 9.76, 107 ± 156, 268 ± 128, 8.33 ± 3.65, and 11.18 ± 0.68 in Japanese participants. Ethiopian women had significantly higher level of serum calcium than Vietnamese and Japanese women (both P Vietnamese women was higher than in women from Japan, the difference was not statistically significant (P > 0.05). Furthermore, compared with Japanese women, Ethiopian women had significantly high iron and copper concentrations (P Vietnamese than Ethiopian women. The study revealed a remarkable difference in serum concentrations of trace elements in women from different countries, implying differences in trace elements in the food or soil. Copyright © 2015 Elsevier Inc. All rights reserved.

  10. High level white noise generator

    International Nuclear Information System (INIS)

    Borkowski, C.J.; Blalock, T.V.

    1979-01-01

    A wide band, stable, random noise source with a high and well-defined output power spectral density is provided which may be used for accurate calibration of Johnson Noise Power Thermometers (JNPT) and other applications requiring a stable, wide band, well-defined noise power spectral density. The noise source is based on the fact that the open-circuit thermal noise voltage of a feedback resistor, connecting the output to the input of a special inverting amplifier, is available at the amplifier output from an equivalent low output impedance caused by the feedback mechanism. The noise power spectral density level at the noise source output is equivalent to the density of the open-circuit thermal noise or a 100 ohm resistor at a temperature of approximately 64,000 Kelvins. The noise source has an output power spectral density that is flat to within 0.1% (0.0043 db) in the frequency range of from 1 KHz to 100 KHz which brackets typical passbands of the signal-processing channels of JNPT's. Two embodiments, one of higher accuracy that is suitable for use as a standards instrument and another that is particularly adapted for ambient temperature operation, are illustrated in this application

  11. High level white noise generator

    Science.gov (United States)

    Borkowski, Casimer J.; Blalock, Theron V.

    1979-01-01

    A wide band, stable, random noise source with a high and well-defined output power spectral density is provided which may be used for accurate calibration of Johnson Noise Power Thermometers (JNPT) and other applications requiring a stable, wide band, well-defined noise power spectral density. The noise source is based on the fact that the open-circuit thermal noise voltage of a feedback resistor, connecting the output to the input of a special inverting amplifier, is available at the amplifier output from an equivalent low output impedance caused by the feedback mechanism. The noise power spectral density level at the noise source output is equivalent to the density of the open-circuit thermal noise or a 100 ohm resistor at a temperature of approximately 64,000 Kelvins. The noise source has an output power spectral density that is flat to within 0.1% (0.0043 db) in the frequency range of from 1 KHz to 100 KHz which brackets typical passbands of the signal-processing channels of JNPT's. Two embodiments, one of higher accuracy that is suitable for use as a standards instrument and another that is particularly adapted for ambient temperature operation, are illustrated in this application.

  12. Analysis of trace gases at ppb levels by proton transfer reaction mass spectrometry (PTR-MS)

    International Nuclear Information System (INIS)

    Lindinger, W.; Hansel, A.

    1996-01-01

    A proton transfer reaction mass spectrometry (PTR-MS) system has been developed which allows for on-line measurements of trace gas components with concentrations as low as 1 ppb. The method is based on reactions of H 3 O + ions, which perform non-dissociative proton transfer to most of the common organic trace constituents but do not react with any of the components present in clean air. Examples of medical information obtained by means of breath analysis, of environmental trace analysis, and examples in the field of food chemistry demonstrate the wide applicability of the method. (Authors)

  13. Determination of trace levels of iodine in table salt by ICP-TOF MS

    International Nuclear Information System (INIS)

    Waqar, F.; Muhammad, B.; Hakim, M.; Jan, S.

    2012-01-01

    An ion exchange method was established for the effective removal of sodium matrix for iodine determination by ICP-TOF-MS technique. Since the direct determination of trace level analytes in the presence of heavy matrix is not recommended by this technique. Therefore, the removal of matrix is essentially required to achieve better detection limits and to avoid memory effects. The extraction system was designed for the removal of matrix prior to the analysis by ICP-MS, various parameters were optimized to achieve efficient removal of matrix. The accuracy of the method was evaluated by spiking salt samples with known amount of iodine (50 mu g/g) and % recoveries were calculated. The recoveries obtained were > 98% with relative standard deviation (RSD) < 5%. The established method was applied for the analysis of commercially available iodized table salt samples. The results and % recoveries are given. The most commonly used iodo metric titration method is not satisfactory as it has 5-10 % quantitative error. Our method is reliable and could be conveniently applied for the determination of iodine in table salt samples. (Orig./A.B.)

  14. Determination of Tetracycline and Fluoroquinolone Antibiotics at Trace Levels in Sludge and Soil

    Directory of Open Access Journals (Sweden)

    Marie-Virginie Salvia

    2015-01-01

    Full Text Available This work describes the development of a sensitive analytical method to determine simultaneously traces of tetracycline and fluoroquinolone antibiotics in sludge and soil, based on PLE extraction, followed by SPE purification and finally an analysis by LC-MS/MS. Recoveries were greater than 87% in the case of fluoroquinolones and between 25.4 and 41.7% for tetracyclines. Low relative standard deviations (<15% were obtained in both matrices. The limits of quantification were comprised between 1.1 and 4.6 ng/g and between 5 and 20 ng/g in soil and sludge, respectively. The method was then successfully applied to the analysis of the target antibiotics in sludge as well as soil that received spreading. The substances most frequently found and with the highest levels were fluoroquinolones with concentrations exceeding 1,000 ng/g in several samples of sludge and up to 16 ng/g in soil.

  15. Trace elements in high purity materials for advanced technology: contribution of neutron activation analysis and radioanalytical technique

    International Nuclear Information System (INIS)

    Gallorini, M.; Pietra, R.; Sabbioni, E.

    1991-01-01

    Neutron activation analysis and radioanalytical techniques have been employed to investigate problems related to trace elements and high purity technology materials. Applications of these techniques are overviewed: semiconductor technology as in the case of As and In ion implantation in high purity silicon; problems related to trace elements impurities in thermometric measurements; coating materials to prevent trace elements contamination in biological sampling and metals release from human prostheses. (author) 8 refs.; 2 figs.; 8 tabs

  16. Optimizing High Level Waste Disposal

    International Nuclear Information System (INIS)

    Dirk Gombert

    2005-01-01

    If society is ever to reap the potential benefits of nuclear energy, technologists must close the fuel-cycle completely. A closed cycle equates to a continued supply of fuel and safe reactors, but also reliable and comprehensive closure of waste issues. High level waste (HLW) disposal in borosilicate glass (BSG) is based on 1970s era evaluations. This host matrix is very adaptable to sequestering a wide variety of radionuclides found in raffinates from spent fuel reprocessing. However, it is now known that the current system is far from optimal for disposal of the diverse HLW streams, and proven alternatives are available to reduce costs by billions of dollars. The basis for HLW disposal should be reassessed to consider extensive waste form and process technology research and development efforts, which have been conducted by the United States Department of Energy (USDOE), international agencies and the private sector. Matching the waste form to the waste chemistry and using currently available technology could increase the waste content in waste forms to 50% or more and double processing rates. Optimization of the HLW disposal system would accelerate HLW disposition and increase repository capacity. This does not necessarily require developing new waste forms, the emphasis should be on qualifying existing matrices to demonstrate protection equal to or better than the baseline glass performance. Also, this proposed effort does not necessarily require developing new technology concepts. The emphasis is on demonstrating existing technology that is clearly better (reliability, productivity, cost) than current technology, and justifying its use in future facilities or retrofitted facilities. Higher waste processing and disposal efficiency can be realized by performing the engineering analyses and trade-studies necessary to select the most efficient methods for processing the full spectrum of wastes across the nuclear complex. This paper will describe technologies being

  17. Variation in levels and removal efficiency of heavy and trace metals ...

    African Journals Online (AJOL)

    CPUT

    trace metals from wastewater treatment plant effluents in Cape Town and .... Geographical locations and design .... The new. Bellville plant uses University of Cape Town design (UCT) ...... batteries, paints, fungicides, textiles, cosmetics, pulp,.

  18. Statistical significance of biomonitoring of marine algae for trace metal levels in a coral environment

    Digital Repository Service at National Institute of Oceanography (India)

    Gopinath, A.; Muraleedharan, N.S.; Chandramohanakumar, N.; Jayalakshmy, K.V.

    towards essential elements, and the concentration of Fe seemed to be the highest in all the species, irrespective of their classification. The trace metal content reported in this study was much lower than the limit prescribed by Food and Agricultural...

  19. Bromate and trace metal levels in bread loaves from outlets within Ile-Ife Metropolis, Southwestern Nigeria

    Directory of Open Access Journals (Sweden)

    J.A.O. Oyekunle

    2014-01-01

    Full Text Available Bread loaves randomly sampled from nine outlets and bakeries within Ile-Ife were analysed to determine their safety levels for human consumption with respect to bromate and trace metal contents. Bromate determination was carried out via spectrophotometric method while trace metals in the digested bread samples were profiled using Flame Atomic Absorption Spectrophotometer. Bromate levels in the analyzed bread samples ranged from 2.051 ± 0.011 μg/g to 66.224 ± 0.014 μg/g while the trace metal levels were of the order: 0.03–0.10 μg/g Co = 0.03–0.10 μg/g Pb < 0.23–0.46 μg/g Cu < 2.23–6.63 μg/g Zn < 25.83–75.53 μg/g Mn. This study revealed that many bread bakers around Ile-Ife had not fully complied with the bromate-free rule stipulated by NAFDAC contrary to the “bromate free” inscribed on the labels of the bread. The bread samples contained both essential and toxic trace metals to levels that could threaten the health of consumers over prolonged regular consumption.

  20. Method development for liquid chromatographic/triple quadrupole mass spectrometric analysis of trace level perfluorocarboxylic acids in articles of commerce

    Science.gov (United States)

    An analytical method to identify and quantify trace levels of C5 to C12 perfluorocarboxylic acids (PFCAs) in articles of commerce (AOC) is developed and rigorously validated. Solid samples were extracted in methanol, and liquid samples were diluted with a solvent consisting of 60...

  1. Ascertaining serum levels of trace elements in melanoma patients using PIXE and HR-ICPMS

    Science.gov (United States)

    Bernardes, S.; Tabacniks, M. H.; Santos, I. D. A. O.; Oliveira, A. F.; Shie, J. N.; Sarkis, J. E. S.; Oliveira, T.

    2014-01-01

    Melanoma is a serious and deadly form of skin cancer. However, patients' chances of survival and recovery are considerably increased when it is diagnosed and treated in its early stages. In this study, trace element concentrations in serum samples from patients with melanoma were measured using PIXE (Proton Induced X-ray Emission) and HR-ICPMS (High-Resolution Inductively Coupled Plasma Mass Spectrometry), with the purpose of correlating these concentrations with the disease. Blood samples from 30 melanoma patients and 116 healthy donors were collected at São Paulo Hospital (protocol CEP 1036/08 UNIFESP). Relevant clinical information on the patients has also been included in the statistical analysis. Analysis of the control group showed different P and Mg concentrations in individuals above and below 40 years of age. P, S, Ca, Cu and Zn concentrations in healthy individuals differed according to gender, highlighting the necessity to include age and gender variables in the case-control analysis. There were also differences in K, S, Ca and Se concentrations between the control and melanoma groups.

  2. Ascertaining serum levels of trace elements in melanoma patients using PIXE and HR-ICPMS

    Energy Technology Data Exchange (ETDEWEB)

    Bernardes, S., E-mail: suene@if.usp.br [Physics Institute, University of São Paulo (Brazil); Tabacniks, M.H. [Physics Institute, University of São Paulo (Brazil); Santos, I.D.A.O.; Oliveira, A.F.; Shie, J.N. [São Paulo Federal University (UNIFESP), São Paulo (Brazil); Sarkis, J.E.S.; Oliveira, T. [Institute of Energy and Nuclear Research (IPEN), Laboratory of Chemical Characterization (LCQ), Center for Chemistry and the Environment - CQMA, Sao Paulo (Brazil)

    2014-01-01

    Melanoma is a serious and deadly form of skin cancer. However, patients’ chances of survival and recovery are considerably increased when it is diagnosed and treated in its early stages. In this study, trace element concentrations in serum samples from patients with melanoma were measured using PIXE (Proton Induced X-ray Emission) and HR-ICPMS (High-Resolution Inductively Coupled Plasma Mass Spectrometry), with the purpose of correlating these concentrations with the disease. Blood samples from 30 melanoma patients and 116 healthy donors were collected at São Paulo Hospital (protocol CEP 1036/08 UNIFESP). Relevant clinical information on the patients has also been included in the statistical analysis. Analysis of the control group showed different P and Mg concentrations in individuals above and below 40 years of age. P, S, Ca, Cu and Zn concentrations in healthy individuals differed according to gender, highlighting the necessity to include age and gender variables in the case-control analysis. There were also differences in K, S, Ca and Se concentrations between the control and melanoma groups.

  3. Input of trace substances to coniferous forests by fog interception at high elevations of Black Forest

    International Nuclear Information System (INIS)

    Winkler, P.; Pahl, S.

    1993-10-01

    The deposition of trace substances to a coniferous forest has been estimated by means of a one-dimensional cloud droplet deposition model. For a period of 21 months the liquid water content has been measured and 89 samples of cloud water from the weather station Feldberg have been analysed for chemical composition. These data and meteorological routine observations have been used as input parameters for the deposition model. Deposition calculations to a 40 years old coniferous forest for the period 1982-1991 showed that the cloud water deposition amounts to 33% of the precipitation amount on the average and varies between 23 and 43% in single years. The highest cloud water deposition rates occur during fall and winter. The trace substance concentration in cloud water has been found to be higher than in precipitation, by a factor between 6 and 12, depending on the type of ions. Typically seasonal variations of normalized ion concentrations could be shown to exist as well as dependencies on wind direction. Air mass transport from the industries of the Stuttgart area resulted in higher trace substance concentrations in cloud water. The deposition of trace substances via fog interception during the summer months is as high and in the winter months higher than that by wet deposition. The forests at high elevations of Black Forest are charged appreciably by fog interception. (orig.). 31 figs., 5 tabs., 39 refs [de

  4. Trace-elements, methylmercury and metallothionein levels in Magellanic penguin (Spheniscus magellanicus) found stranded on the Southern Brazilian coast.

    Science.gov (United States)

    Kehrig, Helena A; Hauser-Davis, Rachel A; Seixas, Tércia G; Fillmann, Gilberto

    2015-07-15

    Magellanic penguins have been reported as good biomonitors for several types of pollutants, including trace-elements. In this context, selenium (Se), total mercury, methylmercury, inorganic mercury (Hg(inorg)), cadmium (Cd) and lead (Pb), as well as metallothionein (MT) levels, were evaluated in the feathers, liver and kidney of juvenile Magellanic penguins found stranded along the coast of Southern Brazil. The highest concentrations of all trace-elements and methylmercury were found in internal organs. Concentrations of Cd and Se in feathers were extremely low in comparison with their concentrations in soft tissues. The results showed that both Se and MT are involved in the detoxification of trace-elements (Cd, Pb and Hg(inorg)) since statistically significant relationships were found in liver. Conversely, hepatic Se was shown to be the only detoxifying agent for methylmercury. Copyright © 2015 Elsevier Ltd. All rights reserved.

  5. Techniques for the measurement of trace moisture in high-purity electronic specialty gases

    International Nuclear Information System (INIS)

    Funke, Hans H.; Grissom, Brad L.; McGrew, Clark E.; Raynor, Mark W.

    2003-01-01

    The control of water vapor (moisture) contamination in process gases is critical to the successful manufacture of semiconductor devices. As specified moisture levels have become more stringent, there is a growing demand for more sensitive analytical methods. Instrumental methods currently being used or in development for measuring trace moisture at ppbv levels include Fourier transform infrared spectroscopy, tunable diode laser absorption spectroscopy, cavity ringdown spectroscopy, intracavity laser spectroscopy, electron impact ionization mass spectrometry, and atmospheric pressure ionization mass spectrometry. In addition, sensor-based technologies such as oscillating quartz crystal microbalances, and chilled mirror-, capacitor-, and electrolytic-based hygrometers operate in this regime. These approaches are presented and reviewed. As the success of each trace moisture method is dependent on the degree to which the different process gases interfere with the measurement process, important process gas applications of the techniques are highlighted. Advantages and disadvantages as well as future developments and trends are also presented

  6. Determination of trace levels of nickel and manganese in soil, vegetable, and water

    Energy Technology Data Exchange (ETDEWEB)

    Khani, Rouhollah; Shemirani, Farzaneh [School of Analytical Chemistry, University College of Science, University of Tehran, Tehran (Iran, Islamic Republic of)

    2010-12-15

    A simple and reliable method for rapid and selective extraction and determination of trace levels of Ni{sup 2+} and Mn{sup 2+} was developed by ionic liquid (IL) based dispersive liquid-liquid microextraction coupled to flame atomic absorption spectrometry (FAAS) detection. The proposed method was successfully applied to the preconcentration and determination of nickel and manganese in soil, vegetable, and water samples. After preconcentration, the settled IL-phase was dissolved in 100 {mu}L of ethanol and aspirated into the FAAS using a home-made microsample introduction system. Injection of 50 {mu}L of each analyte into an air-acetylene flame provided very sensitive spike-like and reproducible signals. Effective parameters such as pH, amount of IL, volume of the disperser solvent, concentration of the chelating agent, and effect of salt concentration were inspected by a (2{sup 5-1}) fractional factorial design to identify the most important parameters and their interactions. Under optimum conditions, preconcentration of 10 mL sample solution permitted the detection of 0.93 {mu}g L{sup -1} Ni{sup 2+} and 0.52 {mu}g L{sup -1} Mn{sup 2+} with enrichment factors 77.2 and 82.6 for Ni{sup 2+} and Mn{sup 2+}, respectively. The accuracy of the procedure was evaluated by analysis of a certified reference material (CRM TMDW-500, drinking water). (Copyright copyright 2010 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  7. Advanced Detection Technology of Trace-level Borate for SG Leakage Monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Seban; Kang, Dukwon; Kim, Seungil; Kim, Hyunki; Heo, Jun; Sung, Jinhyun [Radiation Eng. Center, Shihung (Korea, Republic of); Lee, Dongbum [Academic Support Dept., Seoul (Korea, Republic of)

    2013-05-15

    Many studies have been reported for monitoring technology of steam generator, however, all of these methods have their own limitations. The leakage monitoring technology of steam generator of PWR has also got a limit due to the adoption of specific radionuclides (N-16, Ar-41, H-3, Xe, etc.) generated by nuclear fission, which are available only when reactor output is 20% or more. Most of domestic NPPs apply the N-16 technique for monitoring tube leakage but it has some problem that it is difficult to calculate the leakage rate because neutron flux are not completely formed during low power operation. For example, tube leakage of steam generator occurred in the Uljin nuclear power plant in 2002 during coast down operation for periodic plant maintenance. This plant could not prevent a rupture accident in advance because N-16 method is not possible the leak monitoring less than 20% reactor power. The development of excellent alternative monitoring technology that can monitor the real-time leakage is required under a variety of operating conditions like start-up and abnormal conditions of NPPs. This study was performed to lay a foundation in monitoring the leakage of steam generator coping with the lower output and low power operational condition using trace level of boron which is non-radioactive nuclide to inject control neutron injection. In this study, non-radioactive nuclide boron ion, which existed in the secondary system water, as leakage monitoring indicator was investigated for the separation of complex cation and anion phase. Borate was detected by using borate concentrator column coupled with the ion-exclusion column analytical column, revealing the problem of overlapped peak between fluoride and boron ions. Meanwhile, ion-exchange column could confirm the possibility as a leakage monitoring indicator of steam generator, despite the peak of glycolic acid salts was slightly overlapped. It will be needed for further research regarding the selectivity of the

  8. Advanced Detection Technology of Trace-level Borate for SG Leakage Monitoring

    International Nuclear Information System (INIS)

    Lee, Seban; Kang, Dukwon; Kim, Seungil; Kim, Hyunki; Heo, Jun; Sung, Jinhyun; Lee, Dongbum

    2013-01-01

    Many studies have been reported for monitoring technology of steam generator, however, all of these methods have their own limitations. The leakage monitoring technology of steam generator of PWR has also got a limit due to the adoption of specific radionuclides (N-16, Ar-41, H-3, Xe, etc.) generated by nuclear fission, which are available only when reactor output is 20% or more. Most of domestic NPPs apply the N-16 technique for monitoring tube leakage but it has some problem that it is difficult to calculate the leakage rate because neutron flux are not completely formed during low power operation. For example, tube leakage of steam generator occurred in the Uljin nuclear power plant in 2002 during coast down operation for periodic plant maintenance. This plant could not prevent a rupture accident in advance because N-16 method is not possible the leak monitoring less than 20% reactor power. The development of excellent alternative monitoring technology that can monitor the real-time leakage is required under a variety of operating conditions like start-up and abnormal conditions of NPPs. This study was performed to lay a foundation in monitoring the leakage of steam generator coping with the lower output and low power operational condition using trace level of boron which is non-radioactive nuclide to inject control neutron injection. In this study, non-radioactive nuclide boron ion, which existed in the secondary system water, as leakage monitoring indicator was investigated for the separation of complex cation and anion phase. Borate was detected by using borate concentrator column coupled with the ion-exclusion column analytical column, revealing the problem of overlapped peak between fluoride and boron ions. Meanwhile, ion-exchange column could confirm the possibility as a leakage monitoring indicator of steam generator, despite the peak of glycolic acid salts was slightly overlapped. It will be needed for further research regarding the selectivity of the

  9. Trace metal levels in soils and vegetation from some tin mining ...

    African Journals Online (AJOL)

    Samples of soil and vegetation from some tin mining areas of Nigeria were analysed for lead, zinc, copper and cadmium content. The levels of Pb and Zn were found to be high in some samples. The mean levels of metal in the vegetation were: 86.6+ 36.0, 49.6+ 28.3, 12.6+4.8 and 1.4+0.8 µgg-1 dry weight for Pb, Zn, Cu ...

  10. Ar39 Detection at the 10-16 Isotopic Abundance Level with Atom Trap Trace Analysis

    Science.gov (United States)

    Jiang, W.; Williams, W.; Bailey, K.; Davis, A. M.; Hu, S.-M.; Lu, Z.-T.; O'Connor, T. P.; Purtschert, R.; Sturchio, N. C.; Sun, Y. R.; Mueller, P.

    2011-03-01

    Atom trap trace analysis, a laser-based atom counting method, has been applied to analyze atmospheric Ar39 (half-life=269yr), a cosmogenic isotope with an isotopic abundance of 8×10-16. In addition to the superior selectivity demonstrated in this work, the counting rate and efficiency of atom trap trace analysis have been improved by 2 orders of magnitude over prior results. The significant applications of this new analytical capability lie in radioisotope dating of ice and water samples and in the development of dark matter detectors.

  11. Possibilities of High Resolution Inductively Coupled Plasma Optical Emission Spectrometry in the Determination of Trace Elements in Environmental Materials

    Directory of Open Access Journals (Sweden)

    Nikolaya Velitchkova

    2013-01-01

    Full Text Available This paper presents new quantitative data for the spectral interferences obtained by high resolution 40.68 MHz radial viewing inductively coupled plasma optical emission spectrometry (HR-ICP-OES in the determination of Zn, Cd, Sb, Cu, Mn, Pb, Sn, Cr, U, and Ba in environmental materials in the presence of a complex matrix, containing Al, Ca, Fe, Mg, and Ti. The -concept for quantification of spectral interferences was used. The optimum line selection for trace analysis of a variety of multicomponent matrices requires the choice of prominent lines, which are free or negligibly influenced by line interference problems. The versatility of -concept as basic methodology was experimentally demonstrated in the determination of trace of elements in soil and drinking water. The detection limits are lower in comparison with corresponding threshold concentration levels for soil and drinking water in accordance with environmental regulations. This paper shows the possibilities of present day ICP-OES equipment in the direct determination of trace elements (without preconcentration of impurities in environmental samples.

  12. High precision analysis of trace lithium isotope by thermal ionization mass spectrometry

    International Nuclear Information System (INIS)

    Tang Lei; Liu Xuemei; Long Kaiming; Liu Zhao; Yang Tianli

    2010-01-01

    High precision analysis method of ng lithium by thermal ionization mass spectrometry is developed. By double-filament measurement,phosphine acid ion enhancer and sample pre-baking technique,the precision of trace lithium analysis is improved. For 100 ng lithium isotope standard sample, relative standard deviation is better than 0.086%; for 10 ng lithium isotope standard sample, relative standard deviation is better than 0.90%. (authors)

  13. Statistics for products of traces of high powers of the frobenius class of hyperelliptic curves

    OpenAIRE

    Roditty-Gershon, Edva

    2011-01-01

    We study the averages of products of traces of high powers of the Frobenius class of hyperelliptic curves of genus g over a fixed finite field. We show that for increasing genus g, the limiting expectation of these products equals to the expectation when the curve varies over the unitary symplectic group USp(2g). We also consider the scaling limit of linear statistics for eigenphases of the Frobenius class of hyperelliptic curves, and show that their first few moments are Gaussian.

  14. Investigating the Microscopic Location of Trace Elements in High-Alpine Glacier Ice

    Science.gov (United States)

    Avak, Sven Erik; Birrer, Mario; Laurent, Oscar; Guillong, Marcel; Wälle, Markus; Jenk, Theo Manuel; Bartels-Rausch, Thorsten; Schwikowski, Margit; Eichler, Anja

    2017-04-01

    Past changes in atmospheric pollution can be reconstructed from high-alpine ice core trace element records (Schwikowski et al., 2004). Percolation of meltwater alters the information originally stored in these environmental archives. Eichler et al. (2001) suggested that the preservation of major ions with respect to meltwater percolation depends on their location in the crystal ice lattice, i.e. grain boundaries versus grain interiors. Other studies have also focused on the effect of meltwater on organic pollutant concentrations as well as on stable isotope profiles in ice cores, whereas no information exists about trace elements. Here, we investigate for the first time the effect of the microscopic location of anthropogenic, dust and volcanic related trace elements on the behavior during meltwater percolation by using two different approaches. On the one hand we assess the microscopic location of trace elements indirectly by analyzing trace element concentrations in a high-alpine ice core, which has been shown to be affected by an inflow of meltwater, using discrete inductively coupled plasma mass spectrometry (ICP-MS). Impurities located at grain boundaries are prone to be removed by meltwater and tend to be depleted in the affected section of the record whereas those incorporated into the ice interior are preserved and not disturbed in the record. In the second approach we work towards a direct quantification of differences in concentrations of trace elements between ice grain boundaries and grain interiors in samples both from unaffected and affected sections of this ice core. Therefore we use cryocell laser ablation (LA) ICP-MS, which is the method of choice for the direct in situ chemical analysis of trace elements at a sub-millimeter resolution in glacier ice (Reinhardt et al., 2001, Della Lunga et al., 2014, Sneed et al., 2015). We will present first results of both approaches with regard to the evaluation of the potential of trace elements as environmental

  15. Altitudinal patterns and controls of trace metal distribution in soils of a remote high mountain, Southwest China.

    Science.gov (United States)

    Li, Rui; Bing, Haijian; Wu, Yanhong; Zhou, Jun; Xiang, Zhongxiang

    2018-02-01

    The aim of this study is to reveal the effects of regional human activity on trace metal accumulation in remote alpine ecosystems under long-distance atmospheric transport. Trace metals (Cd, Pb, and Zn) in soils of the Mt. Luoji, Southwest China, were investigated along a large altitudinal gradient [2200-3850 m above sea level (a.s.l.)] to elaborate the key factors controlling their distribution by Pb isotopic composition and statistical models. The concentrations of Cd, Pb, and Zn in the surface soils (O and A horizons) were relatively low at the altitudes of 3500-3700 m a.s.l. The enrichment factors of trace metals in the surface soils increased with altitude. After normalization for soil organic matter, the concentrations of Cd still increased with altitude, whereas those of Pb and Zn did not show a clear altitudinal trend. The effects of vegetation and cold trapping (CTE) (pollutant enrichment by decreasing temperature with increasing altitude) mainly determined the distribution of Cd and Pb in the O horizon, whereas CTE and bedrock weathering (BW) controlled that of Zn. In the A horizon, the distribution of Cd and Pb depended on the vegetation regulation, whereas that of Zn was mainly related to BW. Human activity, including ores mining and fossil fuels combustion, increased the trace metal deposition in the surface soils. The anthropogenic percentage of Cd, Pb, and Zn quantified 92.4, 67.8, and 42.9% in the O horizon, and 74.5, 33.9, and 24.9% in the A horizon, respectively. The anthropogenic metals deposited at the high altitudes of Mt. Luoji reflected the impact of long-range atmospheric transport on this remote alpine ecosystem from southern and southwestern regions.

  16. Analysis of impurities at trace levels in metallic niobium by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Favaro, D.I.T.; Vasconcellos, M.B.A.; Santos, C.

    1989-10-01

    The interest in obtaining niobium of high purity has increased due to the recent applications of this material in both vacuum and high temperature technologies and to its potential uses in the aeronautic and aerospacial industries and in the nuclear energy field. In the present work, a procedure of analysis of impurities in the parts per million level, in eletrolitic and non-eletrolitic niobium samples has been established. The method of neutron activation analysis followed by high resolution gamma ray spectrometry has been used. The elements Al, Na, Mn, Cl and In, in ppm level and Y, in the percentage level, were determined after irradiation from 1 to 20 minutes, under a thermal neutron flux of 10 11 n.cm -2 .s -1 at the IEA-Rl reactor of the IPEN-CNEN/SP. The γ-rays from the radioactive products were measured with a Ge(Li) detector coupled to a 4096 channel analyzer. The elements Ta, Cr and W, in the parts per million level, were determined with irradiation of 8 hours under a thermal neutron flux of 10 12 n.cm -2 .s -1 . (autor) [pt

  17. Detection of trace levels of Pb2+ in tap water at boron-doped diamond electrodes with anodic stripping voltammetry

    International Nuclear Information System (INIS)

    Dragoe, Diana; Spataru, Nicolae; Kawasaki, Ryuji; Manivannan, Ayyakkannu; Spataru, Tanta; Tryk, Donald A.; Fujishima, Akira

    2006-01-01

    Boron-doped diamond (BDD) electrodes were used to investigate the possibility of detecting trace levels of lead by linear-sweep anodic stripping voltammetry. The low limit of detection (2 nM) is an advantage compared to other electrode materials, and it was found that at low pH values, copper concentrations that are usually present in drinking water do not affect to a large extent the detection of lead. These findings recommend anodic stripping voltammetry at the BDD electrodes as a suitable mercury-free method for the determination of trace levels of lead in drinking water. The results obtained for the lead detection in tap water real samples are in excellent agreement with those found by inductively coupled plasma-mass spectrometry (ICP-MS), demonstrating the practical analytical utility of the method

  18. Pulsating potentiometric titration technique for assay of dissolved oxygen in water at trace level.

    Science.gov (United States)

    Sahoo, P; Ananthanarayanan, R; Malathi, N; Rajiniganth, M P; Murali, N; Swaminathan, P

    2010-06-11

    A simple but high performance potentiometric titration technique using pulsating sensors has been developed for assay of dissolved oxygen (DO) in water samples down to 10.0 microg L(-1) levels. The technique involves Winkler titration chemistry, commonly used for determination of dissolved oxygen in water at mg L(-1) levels, with modification in methodology for accurate detection of end point even at 10.0 microg L(-1) levels DO present in the sample. An indigenously built sampling cum pretreatment vessel has been deployed for collection and chemical fixing of dissolved oxygen in water samples from flowing water line without exposure to air. A potentiometric titration facility using pulsating sensors developed in-house is used to carry out titration. The power of the titration technique has been realised in estimation of very dilute solution of iodine equivalent to 10 microg L(-1) O(2). Finally, several water samples containing dissolved oxygen from mg L(-1) to microg L(-1) levels were successfully analysed with excellent reproducibility using this new technique. The precision in measurement of DO in water at 10 microg L(-1) O(2) level is 0.14 (n=5), RSD: 1.4%. Probably for the first time a potentiometric titration technique has been successfully deployed for assay of dissolved oxygen in water samples at 10 microg L(-1) levels. Copyright 2010 Elsevier B.V. All rights reserved.

  19. Pulsating potentiometric titration technique for assay of dissolved oxygen in water at trace level

    International Nuclear Information System (INIS)

    Sahoo, P.; Ananthanarayanan, R.; Malathi, N.; Rajiniganth, M.P.; Murali, N.; Swaminathan, P.

    2010-01-01

    A simple but high performance potentiometric titration technique using pulsating sensors has been developed for assay of dissolved oxygen (DO) in water samples down to 10.0 μg L -1 levels. The technique involves Winkler titration chemistry, commonly used for determination of dissolved oxygen in water at mg L -1 levels, with modification in methodology for accurate detection of end point even at 10.0 μg L -1 levels DO present in the sample. An indigenously built sampling cum pretreatment vessel has been deployed for collection and chemical fixing of dissolved oxygen in water samples from flowing water line without exposure to air. A potentiometric titration facility using pulsating sensors developed in-house is used to carry out titration. The power of the titration technique has been realised in estimation of very dilute solution of iodine equivalent to 10 μg L -1 O 2 . Finally, several water samples containing dissolved oxygen from mg L -1 to μg L -1 levels were successfully analysed with excellent reproducibility using this new technique. The precision in measurement of DO in water at 10 μg L -1 O 2 level is 0.14 (n = 5), RSD: 1.4%. Probably for the first time a potentiometric titration technique has been successfully deployed for assay of dissolved oxygen in water samples at 10 μg L -1 levels.

  20. trace metal level of human blood from dareta village, anka, nigeria

    African Journals Online (AJOL)

    BARTH EKWUEME

    either (or both) as essential or toxic or show a high ... Death from Lead poisoning has occurred in children at blood Lead levels of 1.25 mg/L or ... intake of Lead: adults, 3 mg per person or 50 µg/kg ... U.U. Udiba, National Research Institute for Chemical Technology, P.M.B 1052, Zaria, .... workers exposed to this metal.

  1. Technical Note: A new global database of trace gases and aerosols from multiple sources of high vertical resolution measurements

    Directory of Open Access Journals (Sweden)

    G. E. Bodeker

    2008-09-01

    Full Text Available A new database of trace gases and aerosols with global coverage, derived from high vertical resolution profile measurements, has been assembled as a collection of binary data files; hereafter referred to as the "Binary DataBase of Profiles" (BDBP. Version 1.0 of the BDBP, described here, includes measurements from different satellite- (HALOE, POAM II and III, SAGE I and II and ground-based measurement systems (ozonesondes. In addition to the primary product of ozone, secondary measurements of other trace gases, aerosol extinction, and temperature are included. All data are subjected to very strict quality control and for every measurement a percentage error on the measurement is included. To facilitate analyses, each measurement is added to 3 different instances (3 different grids of the database where measurements are indexed by: (1 geographic latitude, longitude, altitude (in 1 km steps and time, (2 geographic latitude, longitude, pressure (at levels ~1 km apart and time, (3 equivalent latitude, potential temperature (8 levels from 300 K to 650 K and time.

    In contrast to existing zonal mean databases, by including a wider range of measurement sources (both satellite and ozonesondes, the BDBP is sufficiently dense to permit calculation of changes in ozone by latitude, longitude and altitude. In addition, by including other trace gases such as water vapour, this database can be used for comprehensive radiative transfer calculations. By providing the original measurements rather than derived monthly means, the BDBP is applicable to a wider range of applications than databases containing only monthly mean data. Monthly mean zonal mean ozone concentrations calculated from the BDBP are compared with the database of Randel and Wu, which has been used in many earlier analyses. As opposed to that database which is generated from regression model fits, the BDBP uses the original (quality controlled measurements with no smoothing applied in any

  2. Distribution of trace levels of therapeutic gallium in bone as mapped by synchrotron X-ray microscopy

    International Nuclear Information System (INIS)

    Bockman, R.S.; Repo, M.A.; Warrell, R.P. Jr.; Pounds, J.G.; Schidlovsky, G.; Gordon, B.M.; Jones, K.W.

    1990-01-01

    Gallium nitrate, a drug that inhibits calcium release from bone, has been proven a safe and effective treatment for the accelerated bone resorption associated with cancer. Though bone is a target organ for gallium, the kinetics, sites, and effects of gallium accumulation in bone are not known. The authors have used synchrotron X-ray microscopy to map the distribution of trace levels of gallium in bone. After short-term in vivo administration of gallium nitrate to rats, trace (nanogram) amounts of gallium preferentially localized to the metabolically active regions in the metaphysis as well as the endosteal and periosteal surfaces of diaphyseal bone, regions where new bone formation and modeling were occurring. The amounts measured were well below the levels known to be cytotoxic. Iron and zinc, trace elements normally found in bone, were decreased in amount after in vivo administration of gallium. These studies represent a first step toward understanding the mechanism(s) of action of gallium in bone by suggesting the possible cellular, structural, and elemental targets of gallium

  3. Levels, spatial variation and compartmentalization of trace elements in brown algae Cystoseira from marine protected areas of Crimea (Black Sea)

    International Nuclear Information System (INIS)

    Kravtsova, Alexandra V.; Milchakova, Nataliya A.; Frontasyeva, Marina V.

    2015-01-01

    Highlights: • 19 trace elements were determined in Cystoseira spp. from marine protected areas. • Levels of 10 elements were lower than reported data for Black Sea Cystoseira spp. • Concentrations of most trace elements were higher in “branches” than in “stems”. • Spatial variations of V, Co, Ni and Zn can be related to anthropogenic activities. • Al, Sc, Fe, Rb, Cs, Th, U varied depending on geological composition of the coast. - Abstract: Levels of Al, Sc, V, Co, Ni, As, Br, Rb, Sr, Ag, Sb, I, Cs, Ba, Th and U that were rarely or never studied, as well as the concentrations of classically investigated Mn, Fe and Zn in brown algae Cystoseira barbata C. Ag. and Cystoseira crinita (Desf.) Bory from the coastal waters of marine protected areas (Crimea, Black Sea), were determined using neutron activation analysis. Spatial variation and compartmentalization were studied for all 19 trace elements (TE). Concentrations of most TE were higher in “branches” than in “stems”. Spatial variations of V, Co, Ni and Zn can be related to anthropogenic activities while Al, Sc, Fe, Rb, Cs, Th and U varied depending on chemical peculiarities of the coastal zone rocks. TE concentrations in C. crinita from marine protected areas near Tarkhankut peninsula and Cape Fiolent, identified as the most clean water areas, are submitted as the background concentrations

  4. Online preconcentration and determination of trace levels cadmium in water samples using flow injection systems coupled with flame AAS

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, Songlin; Liang, Huading; Yan, Hua; Yan, Zhengzhong; Chen, Suqing; Zhu, Xiandi; Cheng, Miaoxian [School of Pharmaceutical and Chemical Engineering, Taizhou University (China)

    2010-02-15

    A rapid and sensitive method for the determination of trace levels cadmium in water samples by flame atomic absorption spectrometry was developed. It is based on the online sorption of Cd(II) ions on a microcolumn packed with HCl treated bamboo charcoal. In a pH range of 5.0-7.5, Cd(II) ions were effectively retained on the microcolumn, which exhibited fast kinetics, permitting the use of high sample flow rates up to at least 12.8 mL/min without the loss of retention efficiency. The retained Cd(II) ions were quantitatively eluted with HCl (2.0 mol/L) for an online determination. With a preconcentration time of 80 s at a sample loading flow rate of 8.6 mL/min, a sensitivity enhancement factor of 63 was obtained compared with the slope of the linear portion of the calibration curves before and after preconcentration. The calibration graph using the preconcentration system for cadmium was linear with a correlation coefficient of 0.9997, at levels from 1-40 ng/mL. The precision (RSD) for 11 replicate measurements were 3.2% for the determination of 5 ng/mL Cd(II) and 1.8% for 20 ng/mL Cd(II), respectively, and the detection limit (3s) was 0.36 ng/mL. The accuracy was assessed through the determination of a certified reference material, and also through recovery experiments. (Abstract Copyright [2010], Wiley Periodicals, Inc.)

  5. Comparative study on TSPM levels, anions and trace metal concentrations at BARC during the years 2000-2002

    International Nuclear Information System (INIS)

    Saradhi, I.V.; Prathibha, P.; Kothai, G.; Mahadevan, T.N.; Venkat Raj, V.; Kumar, Shaji C.

    2003-01-01

    Both total and respirable suspended particulate matter in the ambient air of Mumbai have been identified as the single largest pollutant associated with the health impacts in the community. This study deals with the extensive monitoring work carried out at BARC, Trombay during the period 2000-2002. The paper also deals with the comparative status of the TSPM levels and select trace metal and anion concentrations. While Pb levels have stabilized over the years following the introduction of unleaded gasoline, sulphate as a major contributor in the fine fraction of SPM assumes importance. The possible source profiles are presented and discussed. (author)

  6. Assessment of trace metal levels in size-resolved particulate matter in the area of Leipzig

    Science.gov (United States)

    Fomba, Khanneh Wadinga; van Pinxteren, Dominik; Müller, Konrad; Spindler, Gerald; Herrmann, Hartmut

    2018-03-01

    Size-resolved trace metal concentrations at four sites in Leipzig (Germany) and its surrounding were assessed between the winter of 2013 and the summer of 2015. The measurements were performed in parallel at; traffic dominated (Leipzig - Mitte, LMI), traffic and residential dominated (Eisenbahnstrasse, EIB), urban background (TROPOS, TRO) and regional background (Melpitz, MEL) sites. In total, 19 trace metals, i.e. K, Ca, Ti, Mn, Fe, Cu, Zn, As, Se, Ba, V, Pb, Ni, Cr, Sr, Sn, Sb, Co and Rb were analysed using total reflection x-ray fluorescence (TXRF). The major metals were Fe, K and Ca with concentrations ranging between; 31-440 ng/m3, 42-153 ng/m3 and 24-322 ng/m3, respectively, while the trace metals with the lowest concentrations were Co, Rb and Se with concentrations of; tire wear (Cu, Sb, Ba, Fe, Zn, Pb), biomass burning (K, Rb), oil and coal combustion (V, Zn, As, Pb). Crustal matter contributed 5-12% in winter and 8-19% in summer of the PM10 mass. Using Cu and Zn as markers for brake and tire wear, respectively, the estimated brake and tire wear contributions to the PM10 mass were 0.1-0.8% and 1.7-2.9%, respectively. The higher contributions were observed at the traffic sites while the lower contributions were observed at the regional background site. In total, non-exhaust emissions could account for about 10-22% of the PM10 mass in the summer and about 7-15% of the PM10 mass in the winter.

  7. Ar-39 Detection at the 10^-16 Isotopic Abundance Level with Atom Trap Trace Analysis

    OpenAIRE

    Jiang, W.; Williams, W. D.; Bailey, K.; Davis, A. M.; Hu, S. -M.; Lu, Z. -T.; O'Connor, T. P.; Purtschert, R.; Sturchio, N. C.; Sun, Y. R.; Mueller, P.

    2011-01-01

    Atom Trap Trace Analysis (ATTA), a laser-based atom counting method, has been applied to analyze atmospheric Ar-39 (half-life = 269 yr), a cosmogenic isotope with an isotopic abundance of 8x10^-16. In addition to the superior selectivity demonstrated in this work, counting rate and efficiency of ATTA have been improved by two orders of magnitude over prior results. Significant applications of this new analytical capability lie in radioisotope dating of ice and water samples and in the develop...

  8. Potential role of peroxisome proliferator activated receptor gamma activation on serum visfatin and trace elements in high fat diet induced type 2 diabetes mellitus.

    Science.gov (United States)

    Tabassum, Arshia; Zaidi, Syeda Nuzhat Fatima; Yasmeen, Kausar; Mahboob, Tabassum

    2018-07-15

    Electrolytes and trace elements dysregulation play an important role in the progression of obesity and diabetes complications. The present study was designed to evaluate the insulin sensitizing effects of peroxisomes proliferators activated receptor gamma (PPAR-γ) agonist on trace elements in obesity induced type 2 diabetes mellitus and correlate with serum visfatin. Wistar rats were categorized into five groups. Group I served as control; Group II fed on high fat diet (HFD); Group III fed on HFD and treated with rosiglitazone (3 mg/kg) for 7 days; Group IV were T2DM rats induce by HFD and low dose of streptozotocin (i.p. 35 mg/kg); Group V was T2DM rats treated with rosiglitazone (3 mg/kg) for 7 days. Serum and tissues electrolytes levels and renal, hepatic and cardiac tissues trace elements were estimated by flame photometer and atomic absorption spectroscopy. Serum visfatin was estimated by ELISA. Pearson correlations were analyzed among fasting blood glucose (FBG), serum visfatin and tissues trace elements. Results of the current study showed hyponatremia, hyperkalemia, hypomagnesemia and hypercalcemia in HFD and T2DM groups. HFD and T2DM also showed elevated copper and iron levels; however, zinc and selenium levels were decreased. Rosiglitazone treatment increased the insulin sensitization and altered these changes. A Strong association was observed among FBG, serum visfatin and trace elements levels of HFD and T2DM. Obesity and diabetes mellitus disturbed visfatin, electrolytes and trace elements homeostasis. Rosiglitazone treatment restored these changes. The results of the study could serve as a basis for further studies for the prevention of diabetic complications. Copyright © 2018 Elsevier Inc. All rights reserved.

  9. Trace elements in sediment samples of the Aswan High Dam Lake

    International Nuclear Information System (INIS)

    Sherief, M.K.; Awadallah, R.M.; Grass, F.

    1981-01-01

    Main and trace elements in Nile sediments of the Aswan High Dam Lake were investigated by means of Instrumental Activation Analysis. It was shown that the composition of the Nile sediments changes in accordance with the large gradients in flow rate and with elution and absorption processes. Particles containing Ca, Ba, Hf, Ti, V, and Na are sedimented preferentially near the headwater of Lake Nubia, whereas some elements are rather uniformly distributed, e.g. Fe, Co, Sm, and Eu, and some, such as Al, Sc, Cs, Th, La, and Ce, show a distinct increase downstream. Some elements do not fit into any of these three groups. (author)

  10. High-level language computer architecture

    CERN Document Server

    Chu, Yaohan

    1975-01-01

    High-Level Language Computer Architecture offers a tutorial on high-level language computer architecture, including von Neumann architecture and syntax-oriented architecture as well as direct and indirect execution architecture. Design concepts of Japanese-language data processing systems are discussed, along with the architecture of stack machines and the SYMBOL computer system. The conceptual design of a direct high-level language processor is also described.Comprised of seven chapters, this book first presents a classification of high-level language computer architecture according to the pr

  11. Determination of base-line levels of trace amounts in pulses and spices using neutron activation technique

    International Nuclear Information System (INIS)

    Zaidi, J.H.; Arif, M.; Fatima, I.; Qureshi, I.H.

    1993-01-01

    It has been established that essential trace elements are vitally important for biochemical systems, whereas toxic elements if present in relatively higher amounts adversely affect these systems. Trace elements reach the human body mainly through foodstuffs. The different articles contain varying amount of toxic and essential elements. It is therefore necessary to asses the adequacy and safety of the diet by determining the base-line levels of these elements. In continuation of our previous work, some varieties of pulses and spices were analyzed using neutron activation technique. Among the four varieties of pulses lentil (lens esculenta) was found to contain higher amounts of essential elements and lower amounts of toxic elements. The daily intake of essential and toxic elements through pulses was estimated and compared with the suggested values. The estimated intake of essential elements is adequate and that of toxic elements is well below the tolerance limit. In spices cumin and caraway seeds were found to contain relatively higher amounts of essential as well as toxic elements. The studies showed that food spices were additional source of trace element intake. (author)

  12. DETERMINATION of the TRACE ELEMENT LEVELS in HAIR of SMOKERS and NON-SMOKERS by ICP-MS

    Directory of Open Access Journals (Sweden)

    Elif Varhan Oral

    2016-09-01

    Full Text Available For at least 50 years, determination of the trace element levels in human hair has been used to assess environmental and vocational exposure to toxic elements . As compared to other biological matrices (e.g. blood, urine, human hair is stable and therefore useful as a matrice. In this study, analyses of toxic and essential trace elements, such as Cd, Pb, Cu and Fe, were done in hair samples which we collected from male smokers (10 people and non-smokers (10 people who live in Diyarbakır, Turkey and concentrations in hair samples were compared. Hair samples were washed by a standard procedure proposed by the International Atomic Energy Agency. Then the samples were dried for 16 h at 110°C in an oven. Solubilization procedure was carried out by nitric acid hydrogen peroxide mixture (3:1 in closed vessels in a microwave oven. Trace element analyses were carried out by using inductively coupled plasma-mass spectrometry (ICP-MS  technique. In our study, while concentrations of Cd, Pb, and Fe elements were found to be considerably higher in smokers than non-smokers, similar results were observed in Cu concentrations. The precision and accuracy of the method was evaluated by applying spike method to samples. Analytical recovery results were found between 91.2% and 104.6%.

  13. Effect of spatial resolution of soil data on predictions of eggshell trace element levels in the Rook Corvus frugilegus.

    Science.gov (United States)

    Orłowski, Grzegorz; Siebielec, Grzegorz; Kasprzykowski, Zbigniew; Dobicki, Wojciech; Pokorny, Przemysław; Wuczyński, Andrzej; Polechoński, Ryszard; Mazgajski, Tomasz D

    2016-12-01

    Although a considerable research effort has gone into studying the dietary pathways of metals to the bodies of laying female birds and their eggs in recent years, no detailed investigations have yet been carried out relating the properties of the biogeochemical environment at large spatial scales to eggshell trace element levels in typical soil-invertebrate feeding birds under natural conditions. We used data from a large-scale nationwide monitoring survey of soil quality in Poland (3724 sampling points from the 43 792 available) to predict levels of five trace elements (copper [Cu], cadmium [Cd], nickel [Ni], zinc [Zn] and lead [Pb]) in Rook Corvus frugilegus eggshells from 42 breeding colonies. Our major aim was to test whether differences exist in the explanatory power of soil data (acidity, content of elements and organic matter, and particle size) used as a correlate of concentrations of eggshell trace elements among four different distances (5, 10, 15 and 20 km) around rookeries. Over all four distances around the rookeries only the concentrations of Cu and Cd in eggshells were positively correlated with those in soil, while eggshell Pb was correlated with the soil Pb level at the two longest distances (15 and 20 km) around the rookeries. The physical properties of soil (primarily the increase in pH) adversely affected eggshell Cd and Pb concentrations. The patterns and factors governing metal bioaccumulation in soil invertebrates and eggshells appear to be coincident, which strongly suggests a general similarity in the biochemical pathways of elements at different levels of the food web. The increasing acidification of arable soil as a result of excessive fertilisation and over-nitrification can enhance the bioavailability of toxic elements to laying females and their eggs. Copyright © 2016 Elsevier Ltd. All rights reserved.

  14. Equilibration-Based Preconcentrating Minicolumn Sensors for Trace Level Monitoring of Radionuclides and Metal Ions in Water without Consumable Reagents

    International Nuclear Information System (INIS)

    Egorov, Oleg B.; O'Hara, Matthew J.; Grate, Jay W.

    2006-01-01

    A sensor technique is described that captures analyte species on a preconcentrating minicolumn containing a selective solid phase sorbent. In this approach, the sample is pumped through the column until the sorbent phase is fully equilibrated with the sample concentration, and the exit concentration equals the inlet concentration. On-column detection of the captured analytes using radiometric and spectroscopic methods are demonstrated. In trace level detection applications, this sensor provides a steady state signal that is proportional to sample analyte concentration and is reversible. The method is demonstrated for the detection of Tc-99 using anion exchange beads mixed with scintillating beads and light detection; Sr-90 using SuperLig 620 beads mixed with scintillating beads and light detection; and hexavalent chromium detection using anion exchange beads with spectroscopic detection. Theory has been developed to describe the signal at equilibration, and to describe analyte uptake as a function of volume and concentration, using parameters and concepts from frontal chromatography. It is shown that experimental sensor behavior closely matches theoretical predictions and that effective sensors can be prepared using low plate number columns. This sensor modality has many desirable characteristics for in situ sensors for trace-level contaminant long-term monitoring where the use of consumable reagents for sensor regeneration would be undesirable. Initial experiments in groundwater matrixes demonstrated the detection of Tc-99 at drinking water level standards (activity of 0.033 Bq/mL) and detection of hexavalent chromium to levels below drinking water standards of 50 ppb

  15. Determination of trace amounts of boron in steel by high frequency plasma torch spectrometry

    International Nuclear Information System (INIS)

    Akiyoshi, Takanori; Tsukamoto, Takako

    1978-01-01

    Trace amount of boron in steel were determined by means of emission spectrometry using high frequency plasma torch. The sensitivity of this method depended on the kind of solvent used, and methyl alcohol gave the best sensitivity. The determination limit of boron in methanol was 0.002 μg/ml. The established method utilized the high sensibility of the plasma torch and the easy distillation of boron in methanol as trimethyl-borate (B(OCH 3 ) 3 ). The sample was dissolved by acids and dehydrated by hot H 2 SO 4 and H 3 Po 4 . After cooling and addition of methanol (60 ml), the solution was distilled to obtain 40 ml of the distillate. The amount of boron in the distillate was determined by the intensity of the spectral line of B 2497.73 A excited by plasma torch. This method was rapid and accurate, particularly in determining trace amounts of boron and the determination range of boron in steel was 0.2 to 150 ppm. This method was also appliciable to stainless steels and other alloys. (auth.)

  16. Levels of trace elements in different varieties of wheat determined by Atomic Absorption Spectroscopy

    International Nuclear Information System (INIS)

    Mohamed, A.E.; Taha, G.M.

    2003-01-01

    Trace elements Ag, Au, Ca, Co, Cr, Cu, Fe, K, Mg, Mn, Na, Ni, Pb, Sr and Zn were determined in six wheat samples purchased from the open market in different localities (Egypt, Saudi Arabia, Yemen, Oman, Dubai and Australia). The dried powdered samples were decomposed in HNO3-HClO4 acids mixtures and elements were determined using recording atomic absorption spectrophotometer. The results were within the safety baseline of all the assayed elements. Certified biological standards, Brown's Kale (BK), Orchard Leaves (OL) and tomato leaves (TOML) were used to assure the accuracy of results. However, Co, Pb and Sr were absent from samples except the Egyptian samples. The obtained databases were statistically treated. Several significant and strong positive correlation coefficients (r=0.506-1.00) between the groups of elements were observed. On the other hand, strong negative correlations (r=0.492-0.873) between another group of elements were also shown. (author)

  17. Washability and Distribution Behaviors of Trace Elements of a High-Sulfur Coal, SW Guizhou, China

    Directory of Open Access Journals (Sweden)

    Wei Cheng

    2018-02-01

    Full Text Available The float-sink test is a commonly used technology for the study of coal washability, which determines optimal separation density for coal washing based on the desired sulfur and ash yield of the cleaned coal. In this study, the float-sink test is adopted for a high-sulfur Late Permian coal from Hongfa coalmine (No.26, southwestern Guizhou, China, to investigate its washability, and to analyze the organic affinities and distribution behaviors of some toxic and valuable trace elements. Results show that the coal is difficult to separate in terms of desulfurization. A cleaned coal could theoretically be obtained with a yield of 75.50%, sulfur 2.50%, and ash yield 11.33% when the separation density is 1.57 g/cm3. Trace elements’ distribution behaviors during the gravity separation were evaluated by correlation analysis and calculation. It was found that Cs, Ga, Ta, Th, Rb, Sb, Nb, Hf, Ba, Pb, In, Cu, and Zr are of significant inorganic affinity; while Sn, Co, Re, U, Mo, V, Cr, Ni, and Be are of relatively strong organic affinity. LREE (Light rare earth elements, however, seem to have weaker organic affinity than HREE (Heavy rare earth elements, which can probably be attributed to lanthanide contraction. When the separation density is 1.60 g/cm3, a large proportion of Sn, Be, Cr, U, V, Mo, Ni, Cd, Pb, and Cu migrate to the cleaned coal, but most of Mn, Sb and Th stay in the gangue. Coal preparation provides alternativity for either toxic elements removal or valuable elements preconcentration in addition to desulfurization and deashing. The enrichment of trace elements in the cleaned coal depends on the predetermined separation density which will influence the yields and ash yields of the cleaned coal.

  18. Effects of Different Levels of Molybdenum on Rumen Microbiota and Trace Elements Changes in Tissues from Goats.

    Science.gov (United States)

    Zhou, Sihui; Zhang, Caiying; Xiao, Qingyang; Zhuang, Yu; Gu, Xiaolong; Yang, Fan; Xing, Chenghong; Hu, Guoliang; Cao, Huabin

    2016-11-01

    Molybdenum (Mo) is an essential trace element for animals and human beings. However, the negative effects on rumen function and distribution of trace elements in tissues induced by excessive Mo have not been well understood. Therefore, the purpose of present study was to investigate the impact of Mo on rumen microbiota, distribution of trace elements in various organs, and hematological parameters of goats. A total of 36 goats were randomly distributed into three groups with equal number and low-Mo and high-Mo groups were orally administered ammonium molybdate at 15 and 45 mg · Mo · kg -1  · BW respectively, while the control group received corresponding quantitative deionized water. The results showed that the total number of ciliate and protozoa protein concentration decreased significantly (P contents significantly decreased (P contents increased (P contents were not obvious (P > 0.05) in other tissues on days 25 and 50. Besides, there was no obvious variation in iron (Fe) contents during whole experiment period (P > 0.05). Furthermore, excessive Mo content had no significant effect on red blood cell (RBC) counts and hemoglobin (HGB) concentration (P > 0.05) on days 25 and 50, while white blood cell (WBC) counts increased significantly (P content could impact the balance of ruminal microorganisms and interfere with the absorption and distribution of Mo and Cu mainly.

  19. Spectrophotometric determination of trace and ultratrace levels of boron in silicon and chlorosilane samples

    International Nuclear Information System (INIS)

    Chen, J.S.; Lin, H.M.; Yang, M.H.

    1991-01-01

    Spectrophotometric methods for the determination of boron in the low μg/g and ng/g range in high-purity silicon and dichloro- and trichlorosilanes were investigated in detail. The procedures established involve dissolution of silicon samples and the hydrolyzed products of chlorosilane samples in hydrofluoric acid-containing reagents followed by evaporation of the silicon matrix as H 2 SiF 6 . The boron retained in the treated sample solution was then determined by a spectrophotometric method using carminic acid as a chromatic reagent. Special effort has been paid to the control of the analytical blank and reproducible determination of boron. The results indicate that addition of mannitol and proper control of the evaporation process are effective in preventing volatilization of boron during the evaporation of silicon matrix and can thus attain high recovery of boron and reproducible analysis. Through meticulous control of the analytical blank and experimental conditions, the limit of detection for boron determination with the established method can be as low as ng/g levels. Application of the methods to the determination of boron in various stages of purification of silicon and trichlorosilane as well as in borophosphosilicate film was conducted. (orig.)

  20. Other-than-high-level waste

    International Nuclear Information System (INIS)

    Bray, G.R.

    1976-01-01

    The main emphasis of the work in the area of partitioning transuranic elements from waste has been in the area of high-level liquid waste. But there are ''other-than-high-level wastes'' generated by the back end of the nuclear fuel cycle that are both large in volume and contaminated with significant quantities of transuranic elements. The combined volume of these other wastes is approximately 50 times that of the solidified high-level waste. These other wastes also contain up to 75% of the transuranic elements associated with waste generated by the back end of the fuel cycle. Therefore, any detailed evaluation of partitioning as a viable waste management option must address both high-level wastes and ''other-than-high-level wastes.''

  1. Maternal and umbilical cord blood levels of mercury, lead, cadmium, and essential trace elements in Arctic Canada

    International Nuclear Information System (INIS)

    Butler Walker, Jody; Houseman, Jan; Seddon, Laura; McMullen, Ed; Tofflemire, Karen; Mills, Carole; Corriveau, Andre; Weber, Jean-Philippe; LeBlanc, Alain; Walker, Mike; Donaldson, Shawn G.; Van Oostdam, Jay

    2006-01-01

    Maternal and umbilical cord blood levels of mercury (Hg), lead (Pb), cadmium (Cd), and the trace elements copper (Cu), zinc (Zn), and selenium (Se) are reported for Inuit, Dene/Metis, Caucasian, and Other nonaboriginal participants from Arctic Canada. This is the first human tissue monitoring program covering the entire Northwest Territories and Nunavut for multiple contaminants and establishes a baseline upon which future comparisons can be made. Results for chlorinated organic pesticides and PCBs for these participants have been reported elsewhere. Between May 1994 and June 1999, 523 women volunteered to participate by giving their written informed consent, resulting in the collection of 386 maternal blood samples, 407 cord samples, and 351 cord:maternal paired samples. Geometric mean (GM) maternal total mercury (THg) concentrations ranged from 0.87μg/L (SD=1.95) in the Caucasian group of participants (n=134) to 3.51μg/L (SD=8.30) in the Inuit group (n=146). The GM of the Inuit group was 2.6-fold higher than that of the Dene/Metis group (1.35μg/L, SD=1.60, n=92) and significantly higher than those of all other groups (P 8 cigarettes/day) was 7.4-fold higher and 12.5-fold higher, respectively, than in nonsmokers. The high percentage of smokers among Inuit (77%) and Dene/Metis (48%) participants highlights the need for ongoing public health action directed at tobacco prevention, reduction, and cessation for women of reproductive age. Pb and THg were detected in more than 95% of all cord blood samples, with GMs of 21 μg/L and 2.7μg/L, respectively, and Cd was detected in 26% of all cord samples, with a GM of 0.08μg/L. Cord:maternal ratios from paired samples ranged from 0.44 to 4.5 for THg, from 0.5 to 10.3 for MeHg, and 0.1 to 9.0 for Pb. On average, levels of THg, MeHg, and Zn were significantly higher in cord blood than in maternal blood (P<0.0001), whereas maternal Cd, Pb, Se, and Cu levels were significantly higher than those in cord blood (P<0

  2. Trace analysis of U, Th and other heavy metals in high purity aluminium with isotope dilution mass spectrometry

    International Nuclear Information System (INIS)

    Beer, B.; Heumann, K.G.

    1992-01-01

    A method for the determination of very low concentrations of U, Th, Fe, Zn, Tl, Cd, Cu and Ag in high purity aluminium with isotope dilution mass spectrometry (IDMS) is developed using a compact and cost-efficient thermal ionization quadrupole mass spectrometer. The detection limits obtained are (in ng/g):U=0.018, Th=0.06, Fe=82, Zn=86, Tl=0.2, Cd=4, Cu=1, Ag=2.6. By this method it is possible to determine the α-emitters U and Th in aluminium down to the sub-ng/g level with good precision of 0.4-10% and 0.5-5%, respectively. The results should also be accurate because IDMS is a reliable analytical method. The dissolution of aluminium is carried out by aqua regia followed by the trace/matrix separation and the isolation of the trace elements by anion exchange chromatography (U, Th, Zn, Tl, Cd), electrodeposition (Cu, Ag) and extraction (Fe). Different aluminium samples are analysed by IDMS and the results are compared with those of other methods. (orig.)

  3. Levels of major and trace elements, including rare earth elements, and ²³⁸U in Croatian tap waters.

    Science.gov (United States)

    Fiket, Željka; Rožmarić, Martina; Krmpotić, Matea; Benedik, Ljudmila

    2015-05-01

    Concentrations of 46 elements, including major, trace, and rare earth elements, and (238)U in Croatian tap waters were investigated. Selected sampling locations include tap waters from various hydrogeological regions, i.e., different types of aquifers, providing insight into the range of concentrations of studied elements and (238)U activity concentrations in Croatian tap waters. Obtained concentrations were compared with the Croatian maximum contaminant levels for trace elements in water intended for human consumption, as well as WHO and EPA drinking water standards. Concentrations in all analyzed tap waters were found in accordance with Croatian regulations, except tap water from Šibenik in which manganese in concentration above maximum permissible concentration (MPC) was measured. Furthermore, in tap water from Osijek, levels of arsenic exceeded the WHO guidelines and EPA regulations. In general, investigated tap waters were found to vary considerably in concentrations of studied elements, including (238)U activity concentrations. Causes of variability were further explored using statistical methods. Composition of studied tap waters was found to be predominately influenced by hydrogeological characteristics of the aquifer, at regional and local level, the existing redox conditions, and the household plumbing system. Rare earth element data, including abundances and fractionation patterns, complemented the characterization and facilitated the interpretation of factors affecting the composition of the analyzed tap waters.

  4. Updated study reporting levels (SRLs) for trace-element data collected for the California Groundwater Ambient Monitoring and Assessment (GAMA) Priority Basin Project, October 2009-March 2013

    Science.gov (United States)

    Davis, Tracy A.; Olsen, Lisa D.; Fram, Miranda S.; Belitz, Kenneth

    2014-01-01

    that warranted establishing an SRL for the first time or increasing the previous SRL. SRLs for Cu (2.1 μg/L), Pb (0.82 μg/L), Mn (0.66 μg/L), Mo (0.023 μg/L), Ni (0.21 μg/L), W (0.023 μg/L), and Zn (6.2 μg/L) were changed to these levels starting October 2009, based on the BD-90/90 concentration for field blanks or the 99th percentile concentration for laboratory or blind blanks. The SRL for Fe was maintained at 6 μg/L, based on the minimum laboratory reporting level for iron. SRLs for these eight constituents were at least an order of magnitude below the regulatory benchmarks established for drinking water for health and aesthetic purposes; therefore, the practice of reporting concentrations below the SRLs as less than or equal to (≤) the measured value would not prevent the identification of values greater than the drinking-water benchmarks. Co was detected in 99 percent of field blanks, and with a BD-90/90 concentration of 0.38 μg/L, all groundwater results starting October 2009 were coded as “reviewed and rejected.” Co does not currently have a regulatory benchmark for drinking water. The primary sources of contamination for trace elements inferred from this review are the equipment or processes used in the field to collect the samples or in the laboratory. In particular, contamination in field blanks of Co and Mn was attributed to the high-capacity 0.45-micrometer pore-size capsule filters that were in regular use beginning in October 2009 by several USGS programs, including the GAMA-PBP and NAWQA Program, for filtering samples for analysis of trace elements. The SRLs determined in this report are intended to be used for GAMA groundwater-quality data for samples collected October 2009 through March 2013, or for as long as quality-control data indicate contamination similar to what was observed in this report; quality-control data should be continuously reviewed and SRLs re-assessed on at least a study-unit basis.

  5. A fiber optic sensor with a metal organic framework as a sensing material for trace levels of water in industrial gases.

    Science.gov (United States)

    Ohira, Shin-Ichi; Miki, Yusuke; Matsuzaki, Toru; Nakamura, Nao; Sato, Yu-ki; Hirose, Yasuo; Toda, Kei

    2015-07-30

    Industrial gases such as nitrogen, oxygen, argon, and helium are easily contaminated with water during production, transfer and use, because there is a high volume fraction of water in the atmosphere (approximately 1.2% estimated with the average annual atmospheric temperature and relative humidity). Even trace water (industrial gases can cause quality problems in the process such as production of semiconductors. Therefore, it is important to monitor and to control trace water levels in industrial gases at each supplying step, and especially during their use. In the present study, a fiber optic gas sensor was investigated for monitoring trace water levels in industrial gases. The sensor consists of a film containing a metal organic framework (MOF). MOFs are made of metals coordinated to organic ligands, and have mesoscale pores that adsorb gas molecules. When the MOF, copper benzene-1,3,5-tricarboxylate (Cu-BTC), was used as a sensing material, we investigated the color of Cu-BTC with water adsorption changed both in depth and tone. Cu-BTC crystals appeared deep blue in dry gases, and then changed to light blue in wet gases. An optical gas sensor with the Cu-BTC film was developed using a light emitting diode as the light source and a photodiode as the light intensity detector. The sensor showed a reversible response to trace water, did not require heating to remove the adsorbed water molecules. The sample gas flow rate did not affect the sensitivity. The obtained limit of detection was 40 parts per billion by volume (ppbv). The response time for sample gas containing 2.5 ppmvH2O was 23 s. The standard deviation obtained for daily analysis of 1.0 ppmvH2O standard gas over 20 days was 9%. Furthermore, the type of industrial gas did not affect the sensitivity. These properties mean the sensor will be applicable to trace water detection in various industrial gases. Copyright © 2015 Elsevier B.V. All rights reserved.

  6. Determination of the levels of trace elements in ten years old children from Antofagasta city, Chile by neutron activation analysis

    International Nuclear Information System (INIS)

    Gras, N.; Munoz, A.L.; Jamett J, A.; Pena C, L.; Santander M, M.

    1988-01-01

    The levels of trace elements in scalp hair of ten years old children of Antofagasta city were determined. For this study, the city was divided in convenient areas. Comparisons between levels of concentrations considering residential areas, sex, values obtained for children of Santiago, and the ranges given in the literature were established. Fifty samples of hair were analyzed by instrumental neutron activation analisis. The elements selected were: As, Br, Co, Cr, Cu, Fe, Hg, K, Na. Sb, and Zn. The effectiveness of wash procedure before irradiation was studied. Ten samples were taken with sufficient amount of hair and each was divided into two, only one of them was washed and both were analyzed. The levels of concentrations were compared. (author)

  7. Development of a mass spectrometrical isotope dilution analysis for determination of trace iodine levels and its application for food samples

    International Nuclear Information System (INIS)

    Schindlmeier, W.

    1984-01-01

    A mass spectrometrical isotope dilution procedure for the determination of trace amounts of iodine in various materials was developed using 129 I as indicator isotope, based on the determination of the 129 I/ 127 I isotope relationship. Negative thermionization was used as ionization method. The analysis procedure, which worked with a standard deviation of between 0,1 and 10% (depending on material tested), was used to determine the iodine level of table salt - both iodized and normal salt (3-6 ppm and less than 0,006 ppm respectively), and food samples with an organic matrix. For comparison the iodine levels were also measured with an iodine-selective electrode. Special preparation and separation procedures were done to suit the sample material. A comparison of the levels of iodine concentration in various powdered milks which were measured by international collaborators using varying methods shows the superior reproducibility of the MS-IDA. (RB) [de

  8. Determination of trace element level in different tissues of the leaping mullet (Liza saliens, Mugilidae) collected from Caspian Sea.

    Science.gov (United States)

    Ebrahimzadeh, Mohammad Ali; Eslami, Shahram; Nabavi, Seyed Fazel; Nabavi, Seyed Mohammad

    2011-12-01

    The concentrations of Cr, Cu, Fe, Mn, Ni, Pb, Cd, and Zn were determined in the brain, heart, liver, gill, gonad, spleen, kidney, and red and white muscles of Liza saliens (leaping mullet). Trace element levels in fish samples were analyzed by flame atomic absorption spectrometry. Among the non-essential metals, the levels of Ni and Pb in the tissues were higher than limits for fish proposed by FAO/WHO, EU, and TFC. Generally, the levels of the non-essential metals were much higher than those of manganese in the red and white muscles. Fe distribution pattern in tissues was in order of spleen > liver > heart > gill > brain > kidney > gonad > red muscle > white muscle. Red muscle was not within the safe limits for human consumption because non-essential metal (Ni, Pb) contents were higher than standard limits.

  9. A highly flexible polymerization technique to prepare fluorescent nanospheres for trace ammonia detection

    International Nuclear Information System (INIS)

    Waich, K.; Sandholzer, M.; Mayr, T.; Slugovc, C.; Klimant, I.

    2010-01-01

    The preparation of pH-sensitive nanospheres by emulsion polymerization for the detection of trace levels of ammonia is described. A fluorescent, polymerizable xanthene dye was copolymerized with styrene, crosslinkers and further copolymers aimed at enhancing the sensitivity to obtain materials for sensing of ammonia. A half-seeded technique was used to obtain stable emulsions of the monomers which were cured to obtain nanospheres with covalently attached active components. The nanospheres were embedded in a silicon matrix and the sensor films obtained were investigated regarding their response to ammonia at concentrations between 25 and 1,000 ppb. Sensors containing polystyrene nanospheres crosslinked with divinylbenzene showed the best performance in ammonia measurements exhibiting detection limits (LODs) of less than 25 ppb ammonia.

  10. Preparation of electrodeless discharge lamps for emission studies of uranium isotopes at trace level

    International Nuclear Information System (INIS)

    Bhowmick, G.K.; Verma, R.; Verma, M.K.; Raman, V.A.; Joshi, A.R.; Deo, M.N.; Gantayet, L.M.; Tiwari, A.K.; Ramakumar, K.L.; Kumar, Navin

    2010-01-01

    A simplified method for preparation of electrodeless discharge lamp for uranium isotopes with specific concerns for 232 U is described. Micro-gram quantities of solid uranium oxides and aqueous solution of uranium nitrate have been used as a starting material for in situ synthesis of uranium tetraiodide. High temperature iodination reaction is carried out in the presence of inert gas neon. By careful design, the preparation time and surface area of quartz reaction tubes have been reduced considerably. The latter decreases the level of contamination which has a direct bearing on the operational lifetime of the lamps. Incorporation of steps to purify the product from an unwanted material improved the stability of the lamps. The procedure provides a safe and convenient way of handling 232 U in particular but can be extended in general to any actinides having radioactivity similar to that of freshly separated 232 U. Characteristic emission of uranium isotopes have been recorded by Fourier Transform Spectrometer to show the satisfactory operation of the lamps as well as their usage for studying emission spectra of the specific isotope.

  11. Distribution of energy levels of quantum free particle on the Liouville surface and trace formulae

    International Nuclear Information System (INIS)

    Bleher, P.M.; Kosygin, D.V.; Sinai, Y.G.

    1995-01-01

    We consider the Weyl asymptotic formula [{E n ≤R 2 }=Area Q.R 2 /(4π)+n(R), for eigenvalues of the Laplace-Beltrami operator on a two-dimensional torus Q with a Liouville metric which is in a sense the most general case of an integrable metric. We prove that if the surface Q is non-degenerate then the remainder term n(R) has the form n(R)=R 1/2 θ(R), where θ(R) is an almost periodic function of the Besicovitch class B 1 , and the Fourier amplitudes and the Fourier frequencies of θ(R) can be expressed via lengths of closed geodesics on Q and other simple geometric characteristics of these geodesics. We prove then that if the surface Q is generic then the limit distribution of θ(R) has a density p(t), which is an entire function of t possessing an asymptotics on a real line, logp(t)∝-C ± t 4 as t→±∞. An explicit expression for the Fourier transform of p(t) via Fourier amplitudes of θ(R) is also given. We obtain the analogue of the Guillemin-Duistermaat trace formula for the Liouville surfaces and discuss its accuracy. (orig.)

  12. Highly selective solid-phase extraction of trace Pd(II) by murexide functionalized halloysite nanotubes

    Energy Technology Data Exchange (ETDEWEB)

    Li Ruijun; He Qun; Hu Zheng; Zhang Shengrui [Department of Chemistry, Lanzhou University, Lanzhou 730000 (China); Key Laboratory of Nonferrous Metal Chemistry and Resources Utilization of Gansu Province, Lanzhou 730000 (China); Zhang Lijun [Faculty of Science and Engineer, Curtin University, Perth, WA 6845 (Australia); Chang Xijun, E-mail: lirj2010@lzu.edu.cn [Department of Chemistry, Lanzhou University, Lanzhou 730000 (China); Key Laboratory of Nonferrous Metal Chemistry and Resources Utilization of Gansu Province, Lanzhou 730000 (China)

    2012-02-03

    Graphical abstract: Murexide functionalized halloysite nanotubes have been developed to separate and concentrate trace Pd(II) from aqueous samples. Parameters that affected the sorption and elution efficiency were studied in column mode, and the new adsorbent presented high selectivity and adsorption capacity for the solid phase extraction of trace Pd(II). Highlights: Black-Right-Pointing-Pointer Murexide modified halloysite nanotubes as adsorbent has been reported originally. Black-Right-Pointing-Pointer This adsorbent has a unique selectivity for Pd(II) at pH 1.0. Black-Right-Pointing-Pointer This adsorbent had high adsorption capacity for Pd(II). Black-Right-Pointing-Pointer The precision and accuracy of the method are satisfactory. - Abstract: The originality on the high efficiency of murexide modified halloysite nanotubes as a new adsorbent of solid phase extraction has been reported to preconcentrate and separate Pd(II) in solution samples. The new adsorbent was confirmed by Fourier transformed infrared spectra, X-ray diffraction, scanning electron microscope, transmission electron microscope and N{sub 2} adsorption-desorption isotherms. Effective preconcentration conditions of analyte were examined using column procedures prior to detection by inductively coupled plasma-optical emission spectrometry (ICP-OES). The effects of pH, the amount of adsorbent, the sample flow rate and volume, the elution condition and the interfering ions were optimized in detail. Under the optimized conditions, Pd(II) could be retained on the column at pH 1.0 and quantitatively eluted by 2.5 mL of 0.01 mol L{sup -1} HCl-3% thiourea solution at a flow rate of 2.0 mL min{sup -1}. The analysis time was 5 min. An enrichment factor of 120 was accomplished. Common interfering ions did not interfere in both separation and determination. The maximum adsorption capacity of the adsorbent at optimum conditions was found to be 42.86 mg g{sup -1} for Pd(II). The detection limit (3{sigma}) of

  13. Highly selective solid-phase extraction of trace Pd(II) by murexide functionalized halloysite nanotubes

    International Nuclear Information System (INIS)

    Li Ruijun; He Qun; Hu Zheng; Zhang Shengrui; Zhang Lijun; Chang Xijun

    2012-01-01

    Graphical abstract: Murexide functionalized halloysite nanotubes have been developed to separate and concentrate trace Pd(II) from aqueous samples. Parameters that affected the sorption and elution efficiency were studied in column mode, and the new adsorbent presented high selectivity and adsorption capacity for the solid phase extraction of trace Pd(II). Highlights: ► Murexide modified halloysite nanotubes as adsorbent has been reported originally. ► This adsorbent has a unique selectivity for Pd(II) at pH 1.0. ► This adsorbent had high adsorption capacity for Pd(II). ► The precision and accuracy of the method are satisfactory. - Abstract: The originality on the high efficiency of murexide modified halloysite nanotubes as a new adsorbent of solid phase extraction has been reported to preconcentrate and separate Pd(II) in solution samples. The new adsorbent was confirmed by Fourier transformed infrared spectra, X-ray diffraction, scanning electron microscope, transmission electron microscope and N 2 adsorption–desorption isotherms. Effective preconcentration conditions of analyte were examined using column procedures prior to detection by inductively coupled plasma-optical emission spectrometry (ICP-OES). The effects of pH, the amount of adsorbent, the sample flow rate and volume, the elution condition and the interfering ions were optimized in detail. Under the optimized conditions, Pd(II) could be retained on the column at pH 1.0 and quantitatively eluted by 2.5 mL of 0.01 mol L −1 HCl–3% thiourea solution at a flow rate of 2.0 mL min −1 . The analysis time was 5 min. An enrichment factor of 120 was accomplished. Common interfering ions did not interfere in both separation and determination. The maximum adsorption capacity of the adsorbent at optimum conditions was found to be 42.86 mg g −1 for Pd(II). The detection limit (3σ) of the method was 0.29 ng mL −1 , and the relative standard deviation (RSD) was 3.1% (n = 11). The method was

  14. Accurate determination of ultra-trace levels of Ti in blood serum using ICP-MS/MS

    International Nuclear Information System (INIS)

    Balcaen, Lieve; Bolea-Fernandez, Eduardo; Resano, Martín; Vanhaecke, Frank

    2014-01-01

    Graphical abstract: -- Highlights: •Novel method for determination of Ti at ultra-trace levels in clinical samples (serum). •Novel method based on Ti(NH 3 ) 6 + reaction product ion formation and double mass selection using recently introduced ICP-QQQ instrumentation. •Lowest limits of detection ever obtained using quadrupole-based instrumentation for Ti. •Accurate determination of basal levels of Ti in blood serum. -- Abstract: Ti is frequently used in implants and prostheses and it has been shown before that the presence of these in the human body can lead to elevated Ti concentrations in body fluids such as serum and urine. As identification of the exact mechanisms responsible for this increase in Ti concentrations, and the risks associated with it, are not fully understood, it is important to have sound analytical methods that enable straightforward quantification of Ti levels in body fluids (for both implanted and non-implanted individuals). Until now, only double-focusing sector field ICP-mass spectrometry (SF-ICP-MS) offered limits of detection that are good enough to deal with the very low basal levels of Ti in human serum. This work reports on the development of a novel method for the accurate and precise determination of trace levels of Ti in human serum samples, based on the use of ICP-MS/MS. O 2 and NH 3 /He have been compared as reaction gases. While the use of O 2 did not enable to overcome all spectral interferences, it has been shown that conversion of Ti + ions into Ti(NH 3 ) 6 + cluster ions by using NH 3 /He as a reaction gas in an ICP-QQQ-MS system, operated in MS/MS mode, provided interference-free conditions and sufficiently low limits of detection, down to 3 ng L −1 (instrumental detection limit obtained for the most abundant Ti isotope). The accuracy of the method proposed was evaluated by analysis of a Seronorm Trace Elements Serum L-1 reference material and by comparing the results obtained with those achieved by means of SF

  15. Real-time monitoring of trace-level VOCs by an ultrasensitive compact lamp-based VUV photoionization mass spectrometer

    Science.gov (United States)

    Sun, W. Q.; Shu, J. N.; Zhang, P.; Li, Z.; Li, N. N.; Liang, M.; Yang, B.

    2015-06-01

    In this study, we report on the development of a compact lamp-based vacuum ultraviolet (VUV) photoionization mass spectrometer (PIMS; hereafter referred to as VUV-PIMS) in our laboratory; it is composed of a radio frequency-powered VUV lamp, a VUV photoionizer, an ion-immigration region, and a reflection time-of-flight mass spectrometer. By utilizing the novel photoionizer consisting of a photoionization cavity and a VUV light baffle, extremely low background noise was obtained. An ultrasensitive detection limit (2σ) of 3 pptv was achieved for benzene after an acquisition time of 10 s. To examine its potential for application in real-time sample monitoring, the developed VUV-PIMS was employed for the continuous measurement of urban air for six days in Beijing, China. Strong signals of trace-level volatile organic compounds such as benzene and its alkylated derivatives were observed in the mass spectra. These initial experimental results reveal that the instrument can be used for the online monitoring of trace-level species in the atmosphere.

  16. The Polypyrrole/Multiwalled Carbon Nanotube Modified Au Microelectrode for Sensitive Electrochemical Detection of Trace Levels of Pb2+

    Directory of Open Access Journals (Sweden)

    Xuxing Zhu

    2017-03-01

    Full Text Available The sensitive detection of trace levels of heavy metal ions such as Pb2+ is of significant importance due to the health hazard they pose. In this paper, we present a polypyrrole (PPy/multiwalled carbon nanotube (MWCNT-modified Au microelectrode. The PPy/MWCNT composite film was electrochemically deposited on the microelectrode by cyclic voltammetry (CV. The composite film was investigated by scanning electron microscope (SEM, CV, and electrochemical impedance spectroscopy (EIS, and the results show that this film presents a uniformly distributed and web-like entangled structure and good conductivity. Differential pulse stripping voltammetry (DPSV was applied to determine trace levels of Pb2+. Experimental conditions including accumulation time and deposition potential were optimized. In optimal conditions, the PPy/MWCNT-modified microelectrode performed sensitive detection of Pb2+ within a concentration range from 1 to 100 μg·L−1, and the limit of detection was 0.65 μg·L−1 at the signal-to-noise ratio of three.

  17. Trace Element Compositions and Defect Structures of High-Purity Quartz from the Southern Ural Region, Russia

    Directory of Open Access Journals (Sweden)

    Jens Götze

    2017-10-01

    Full Text Available Quartz samples of different origin from 10 localities in the Southern Ural region, Russia have been investigated to characterize their trace element compositions and defect structures. The analytical combination of cathodoluminescence (CL microscopy and spectroscopy, electron paramagnetic resonance (EPR spectroscopy, and trace-element analysis by inductively coupled plasma mass spectrometry (ICP-MS revealed that almost all investigated quartz samples showed very low concentrations of trace elements (cumulative concentrations of <50 ppm with <30 ppm Al and <10 ppm Ti and low abundances of paramagnetic defects, defining them economically as “high-purity” quartz (HPQ suitable for high-tech applications. EPR and CL data confirmed the low abundances of substitutional Ti and Fe, and showed Al to be the only significant trace element structurally bound in the investigated quartz samples. CL microscopy revealed a heterogeneous distribution of luminescence centres (i.e., luminescence active trace elements such as Al as well as features of deformation and recrystallization. It is suggested that healing of defects due to deformation-related recrystallization and reorganization processes of the quartz lattice during retrograde metamorphism resulted in low concentrations of CL activator and other trace elements or vacancies, and thus are the main driving processes for the formation of HPQ deposits in the investigated area.

  18. SIGWX Charts - High Level Significant Weather

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — High level significant weather (SIGWX) forecasts are provided for the en-route portion of international flights. NOAA's National Weather Service Aviation Center...

  19. Cloud point extraction and spectrophotometric determination of mercury species at trace levels in environmental samples.

    Science.gov (United States)

    Ulusoy, Halil İbrahim; Gürkan, Ramazan; Ulusoy, Songül

    2012-01-15

    A new micelle-mediated separation and preconcentration method was developed for ultra-trace quantities of mercury ions prior to spectrophotometric determination. The method is based on cloud point extraction (CPE) of Hg(II) ions with polyethylene glycol tert-octylphenyl ether (Triton X-114) in the presence of chelating agents such as 1-(2-pyridylazo)-2-naphthol (PAN) and 4-(2-thiazolylazo) resorcinol (TAR). Hg(II) ions react with both PAN and TAR in a surfactant solution yielding a hydrophobic complex at pH 9.0 and 8.0, respectively. The phase separation was accomplished by centrifugation for 5 min at 3500 rpm. The calibration graphs obtained from Hg(II)-PAN and Hg(II)-TAR complexes were linear in the concentration ranges of 10-1000 μg L(-1) and 50-2500 μg L(-1) with detection limits of 1.65 and 14.5 μg L(-1), respectively. The relative standard deviations (RSDs) were 1.85% and 2.35% in determinations of 25 and 250 μg L(-1) Hg(II), respectively. The interference effect of several ions were studied and seen commonly present ions in water samples had no significantly effect on determination of Hg(II). The developed methods were successfully applied to determine mercury concentrations in environmental water samples. The accuracy and validity of the proposed methods were tested by means of five replicate analyses of the certified standard materials such as QC Metal LL3 (VWR, drinking water) and IAEA W-4 (NIST, simulated fresh water). Copyright © 2011 Elsevier B.V. All rights reserved.

  20. Levels of some trace elements in serum of esophageal cancer patients

    International Nuclear Information System (INIS)

    Saeed, D. M. A.

    2011-01-01

    The aim of this study is to measure the concentrations of six trace elements (Zn, Se, Fe, Co, Rb, Hg) in the serum of patients with esophageal cancer who were newly diagnosed before undergoing any type of treatment. Biopsy was taken from diseased esophagus and examined histologically. A total of 43 samples of patients and 36 samples from healthy control group was collected, which were then dried by freeze drying. Then analyzed by neutron activation analysis technology, using research reactor in Syria (the miniature neutron source, MNSR) with neutron flux of 1x10''1''2 n.cm ''-''2 s''-''1 was performed. Certified reference sample from the International Agency were obtained for quality control analysis to ensure the reliability of the device. All six elements were statistically analyzed, the study proved statistical significant difference concentration of following five elements, Zn, Se, Fe, Co, Rb in the serum of patients compared to the serum samples of healthy people. The concentration of Zn and Se in patients serum were less compared to serum of healthy individuals, and the concentrations of Fe, Co, Rb in serum of patients were higher than its that the serum of healthy individuals. While the concentrations of Hg was found to be higher in serum of healthy individuals compared to patients serum, but without statistical significant. The concentration presented by means with standard deviation. The findings were compared to results obtained from literature. All five elements compatible with literature. Hg has not been investigated in such studies before. Selenium and zinc supplementation are need by cancer patient in order to enhance and increase the chances for natural immunological of cancer.(Author)

  1. Levels of some trace elements in serum of esophageal cancer patients

    Energy Technology Data Exchange (ETDEWEB)

    Saeed, D M. A. [Sudan Academy of Sciences, Atomic Energy Council, Khartoum (Sudan)

    2011-01-15

    The aim of this study is to measure the concentrations of six trace elements (Zn, Se, Fe, Co, Rb, Hg) in the serum of patients with esophageal cancer who were newly diagnosed before undergoing any type of treatment. Biopsy was taken from diseased esophagus and examined histologically. A total of 43 samples of patients and 36 samples from healthy control group was collected, which were then dried by freeze drying. Then analyzed by neutron activation analysis technology, using research reactor in Syria (the miniature neutron source, MNSR) with neutron flux of 1x10''1''2 n.cm ''-''2 s''-''1 was performed. Certified reference sample from the International Agency were obtained for quality control analysis to ensure the reliability of the device. All six elements were statistically analyzed, the study proved statistical significant difference concentration of following five elements, Zn, Se, Fe, Co, Rb in the serum of patients compared to the serum samples of healthy people. The concentration of Zn and Se in patients serum were less compared to serum of healthy individuals, and the concentrations of Fe, Co, Rb in serum of patients were higher than its that the serum of healthy individuals. While the concentrations of Hg was found to be higher in serum of healthy individuals compared to patients serum, but without statistical significant. The concentration presented by means with standard deviation. The findings were compared to results obtained from literature. All five elements compatible with literature. Hg has not been investigated in such studies before. Selenium and zinc supplementation are need by cancer patient in order to enhance and increase the chances for natural immunological of cancer.(Author)

  2. Recovering method for high level radioactive material

    International Nuclear Information System (INIS)

    Fukui, Toshiki

    1998-01-01

    Offgas filters such as of nuclear fuel reprocessing facilities and waste control facilities are burnt, and the burnt ash is melted by heating, and then the molten ashes are brought into contact with a molten metal having a low boiling point to transfer the high level radioactive materials in the molten ash to the molten metal. Then, only the molten metal is evaporated and solidified by drying, and residual high level radioactive materials are recovered. According to this method, the high level radioactive materials in the molten ashes are transferred to the molten metal and separated by the difference of the distribution rate of the molten ash and the molten metal. Subsequently, the molten metal to which the high level radioactive materials are transferred is heated to a temperature higher than the boiling point so that only the molten metal is evaporated and dried to be removed, and residual high level radioactive materials are recovered easily. On the other hand, the molten ash from which the high level radioactive material is removed can be discarded as ordinary industrial wastes as they are. (T.M.)

  3. Implementation and assessment of high-resolution numerical methods in TRACE

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Dean, E-mail: wangda@ornl.gov [Oak Ridge National Laboratory, 1 Bethel Valley RD 6167, Oak Ridge, TN 37831 (United States); Mahaffy, John H.; Staudenmeier, Joseph; Thurston, Carl G. [U.S. Nuclear Regulatory Commission, Washington, DC 20555 (United States)

    2013-10-15

    Highlights: • Study and implement high-resolution numerical methods for two-phase flow. • They can achieve better numerical accuracy than the 1st-order upwind scheme. • They are of great numerical robustness and efficiency. • Great application for BWR stability analysis and boron injection. -- Abstract: The 1st-order upwind differencing numerical scheme is widely employed to discretize the convective terms of the two-phase flow transport equations in reactor systems analysis codes such as TRACE and RELAP. While very robust and efficient, 1st-order upwinding leads to excessive numerical diffusion. Standard 2nd-order numerical methods (e.g., Lax–Wendroff and Beam–Warming) can effectively reduce numerical diffusion but often produce spurious oscillations for steep gradients. To overcome the difficulties with the standard higher-order schemes, high-resolution schemes such as nonlinear flux limiters have been developed and successfully applied in numerical simulation of fluid-flow problems in recent years. The present work contains a detailed study on the implementation and assessment of six nonlinear flux limiters in TRACE. These flux limiters selected are MUSCL, Van Leer (VL), OSPRE, Van Albada (VA), ENO, and Van Albada 2 (VA2). The assessment is focused on numerical stability, convergence, and accuracy of the flux limiters and their applicability for boiling water reactor (BWR) stability analysis. It is found that VA and MUSCL work best among of the six flux limiters. Both of them not only have better numerical accuracy than the 1st-order upwind scheme but also preserve great robustness and efficiency.

  4. Implementation and assessment of high-resolution numerical methods in TRACE

    International Nuclear Information System (INIS)

    Wang, Dean; Mahaffy, John H.; Staudenmeier, Joseph; Thurston, Carl G.

    2013-01-01

    Highlights: • Study and implement high-resolution numerical methods for two-phase flow. • They can achieve better numerical accuracy than the 1st-order upwind scheme. • They are of great numerical robustness and efficiency. • Great application for BWR stability analysis and boron injection. -- Abstract: The 1st-order upwind differencing numerical scheme is widely employed to discretize the convective terms of the two-phase flow transport equations in reactor systems analysis codes such as TRACE and RELAP. While very robust and efficient, 1st-order upwinding leads to excessive numerical diffusion. Standard 2nd-order numerical methods (e.g., Lax–Wendroff and Beam–Warming) can effectively reduce numerical diffusion but often produce spurious oscillations for steep gradients. To overcome the difficulties with the standard higher-order schemes, high-resolution schemes such as nonlinear flux limiters have been developed and successfully applied in numerical simulation of fluid-flow problems in recent years. The present work contains a detailed study on the implementation and assessment of six nonlinear flux limiters in TRACE. These flux limiters selected are MUSCL, Van Leer (VL), OSPRE, Van Albada (VA), ENO, and Van Albada 2 (VA2). The assessment is focused on numerical stability, convergence, and accuracy of the flux limiters and their applicability for boiling water reactor (BWR) stability analysis. It is found that VA and MUSCL work best among of the six flux limiters. Both of them not only have better numerical accuracy than the 1st-order upwind scheme but also preserve great robustness and efficiency

  5. Studies of cation exchange for the isolation and concentration of trace level components of complex aqueous mixtures

    International Nuclear Information System (INIS)

    Kaczvinsky, J.R. Jr.

    1984-01-01

    Trace level organic bases are concentrated from aqueous solution by cation exchange on a column of sulfonated macroreticular XAD-4 resin. Washing of the column with organic solvents removes neutrals and acids. Ammonia gas is introduced into the column prior to elution of the basic organics with either methanol or ether containing ammonia. After solvent evaporation, the concentrated sample is analyzed by gas chromatography. Recoveries of over 85% are found with at least one of the eluents for over 50 bases tested at levels < 1 ppm. Improved recoveries and reproducibility are seen over a simple ether extraction procedure. Samples of river water, shale oil process water, and supernatant from an agricultural chemical disposal pit are analyzed. Preliminary studies of functionalized poly(styrene-divinylbenzene)s, coated exchangers, and liquid ion exchangers as possible approaches to nuclear waste decontamination are performed

  6. The determination of low level trace elements in coals by laser ablation-inductively coupled plasma-mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Booth, C.A.; Spears, D.A.; Krause, P.; Cox, A.G. [University of Sheffield, Sheffield (United Kingdom). Dept. of Earth Sciences

    1999-11-01

    The rapid determination of elements present in low level concentrations in bituminous coals is possible using laser abalation-inductively coupled plasma-mass spectrometry (l.a.-i.c.p.-m.s.). A wide range of trace elements can routinely be determined using this technique but it is for environmentally sensitive elements, such as As, Cd, Mo, Sb, Se and Hg, that it is of most use due to the low levels of detection. Calibration of the i.c.p.-m.s. was achieved using a series of uncertified coals and the method evaluated using the South African certified coals, Sarm 18, 19 and 20. A critical evaluation of the data obtained shows that for many of the elements studied the results obtained are both accurate and precise, even at very low concentrations, with the limits of detection for all of the elements being in the {mu}g/kg (parts per billion) range. 6 refs., 3 figs., 9 tabs.

  7. Multi-trace element levels and arsenic speciation in urine of e-waste recycling workers from Agbogbloshie, Accra in Ghana

    Energy Technology Data Exchange (ETDEWEB)

    Asante, Kwadwo Ansong [Center for Marine Environmental Studies (CMES), Ehime University, Bunkyo-cho 2-5, Matsuyama 790-8577 (Japan); CSIR Water Research Institute, P. O. Box AH 38, Achimota, Accra (Ghana); Agusa, Tetsuro [Center for Marine Environmental Studies (CMES), Ehime University, Bunkyo-cho 2-5, Matsuyama 790-8577 (Japan); Biney, Charles Augustus [Volta Basin Authority (VBA), 10 P. O. Box 13621, Ouagadougou 10 (Burkina Faso); Agyekum, William Atuobi; Bello, Mohammed [CSIR Water Research Institute, P. O. Box AH 38, Achimota, Accra (Ghana); Otsuka, Masanari [Center for Marine Environmental Studies (CMES), Ehime University, Bunkyo-cho 2-5, Matsuyama 790-8577 (Japan); Ehime Prefectural Institute of Public Health and Environmental Science, 8-234 Sanban-cho, Matsuyama 790-0003 (Japan); Itai, Takaaki; Takahashi, Shin [Center for Marine Environmental Studies (CMES), Ehime University, Bunkyo-cho 2-5, Matsuyama 790-8577 (Japan); Tanabe, Shinsuke, E-mail: shinsuke@agr.ehime-u.ac.jp [Center for Marine Environmental Studies (CMES), Ehime University, Bunkyo-cho 2-5, Matsuyama 790-8577 (Japan)

    2012-05-01

    To understand human contamination by multi-trace elements (TEs) in electrical and electronic waste (e-waste) recycling site at Agbogbloshie, Accra in Ghana, this study analyzed TEs and As speciation in urine of e-waste recycling workers. Concentrations of Fe, Sb, and Pb in urine of e-waste recycling workers were significantly higher than those of reference sites after consideration of interaction by age, indicating that the recycling workers are exposed to these TEs through the recycling activity. Urinary As concentration was relatively high, although the level in drinking water was quite low. Speciation analysis of As in human urine revealed that arsenobetaine and dimethylarsinic acid were the predominant As species and concentrations of both species were positively correlated with total As concentration as well as between each other. These results suggest that such compounds may be derived from the same source, probably fish and shellfish and greatly influence As exposure levels. To our knowledge, this is the first study on human contamination resulting from the primitive recycling of e-waste in Ghana. This study will contribute to the knowledge about human exposure to trace elements from an e-waste site in a less industrialized region so far scantly covered in the literature. - Highlights: Black-Right-Pointing-Pointer Exposure status of trace elements in e-waste recycling workers was assessed in Ghana. Black-Right-Pointing-Pointer Concentrations of Fe, Sb, and Pb in urine of e-waste workers were significantly higher than those of the reference subjects. Black-Right-Pointing-Pointer This study is the first to investigate human contamination arising from primitive recycling of e-waste arguably from Africa.

  8. Multi-trace element levels and arsenic speciation in urine of e-waste recycling workers from Agbogbloshie, Accra in Ghana

    International Nuclear Information System (INIS)

    Asante, Kwadwo Ansong; Agusa, Tetsuro; Biney, Charles Augustus; Agyekum, William Atuobi; Bello, Mohammed; Otsuka, Masanari; Itai, Takaaki; Takahashi, Shin; Tanabe, Shinsuke

    2012-01-01

    To understand human contamination by multi-trace elements (TEs) in electrical and electronic waste (e-waste) recycling site at Agbogbloshie, Accra in Ghana, this study analyzed TEs and As speciation in urine of e-waste recycling workers. Concentrations of Fe, Sb, and Pb in urine of e-waste recycling workers were significantly higher than those of reference sites after consideration of interaction by age, indicating that the recycling workers are exposed to these TEs through the recycling activity. Urinary As concentration was relatively high, although the level in drinking water was quite low. Speciation analysis of As in human urine revealed that arsenobetaine and dimethylarsinic acid were the predominant As species and concentrations of both species were positively correlated with total As concentration as well as between each other. These results suggest that such compounds may be derived from the same source, probably fish and shellfish and greatly influence As exposure levels. To our knowledge, this is the first study on human contamination resulting from the primitive recycling of e-waste in Ghana. This study will contribute to the knowledge about human exposure to trace elements from an e-waste site in a less industrialized region so far scantly covered in the literature. - Highlights: ► Exposure status of trace elements in e-waste recycling workers was assessed in Ghana. ► Concentrations of Fe, Sb, and Pb in urine of e-waste workers were significantly higher than those of the reference subjects. ► This study is the first to investigate human contamination arising from primitive recycling of e-waste arguably from Africa.

  9. Disposal of high level and intermediate level radioactive wastes

    International Nuclear Information System (INIS)

    Flowers, R.H.

    1991-01-01

    The waste products from the nuclear industry are relatively small in volume. Apart from a few minor gaseous and liquid waste streams, containing readily dispersible elements of low radiotoxicity, all these products are processed into stable solid packages for disposal in underground repositories. Because the volumes are small, and because radioactive wastes are latecomers on the industrial scene, a whole new industry with a world-wide technological infrastructure has grown up alongside the nuclear power industry to carry out the waste processing and disposal to very high standards. Some of the technical approaches used, and the Regulatory controls which have been developed, will undoubtedly find application in the future to the management of non-radioactive toxic wastes. The repository site outlined would contain even high-level radioactive wastes and spent fuels being contained without significant radiation dose rates to the public. Water pathway dose rates are likely to be lowest for vitrified high-level wastes with spent PWR fuel and intermediate level wastes being somewhat higher. (author)

  10. Fibroin/dodecanol floating solidification microextraction for the preconcentration of trace levels of flavonoids in complex matrix samples.

    Science.gov (United States)

    Chen, Xuan; Li, Jie; Hu, Shuang; Bai, Xiaohong; Zhao, Haodong; Zhang, Yi

    2018-01-01

    A new fibroin/dodecanol floating solidification microextraction, coupled with high performance liquid chromatography, was developed and applied for enrichment and quantification of the trace flavonoids in traditional Chinese medicine and biological samples. Also, fibroin sensibilization mechanism was described, and influence of sample matrix to enrichment factor was investigated. In this method, a homogeneous fibroin/dodecanol of dispersed solution was employed as microextraction phase to flavonoids (myricetin, quercetin, isorhamnetin, chrysin, kaempferide), the several critical parameters affecting the performance, such as organic extractant, amount of fibroin in organic extractant, volume of extraction phase, dispersant, salt concentration, pH of sample phase, stirring rate, extraction time, and volume of sample phase were tested and optimized. Under the optimized conditions, enrichment factor of flavonoids ranged from 42.4 to 238.1 in different samples, excellent linearities with r 2 ≥ 0.9968 for all analytes were achieved, limits of detection were less than or equal to 5.0ng/mL, average recoveries were 92.5% to 115.0% in different samples. The new procedure is simple, fast, low cost, environmentally friendly and high EF, it can also be applied to the concentration and enrichment of the trace flavonoids in other complex matrixes. Copyright © 2017. Published by Elsevier B.V.

  11. Resuspension of trace metals in Belgrade under conditions of drastically reduced emission levels

    Energy Technology Data Exchange (ETDEWEB)

    Vukmirovic, Z; Marendic-Miljkovic, J; Rajsic, S; Tasic, M; Novakovic, V [Institute of Physics, Belgrade-Zemun (Yugoslavia)

    1997-01-01

    Deposition rates of trace metals (Pb, Cu, Zn, Cd) were determined at the Meteorological Station in New Belgrade (H{sub s} = 74 m; {psi} = 44{degree}49{prime}N and {lambda} = 20{degree}24{prime}E) in the hydrological year 1992/93 (1 November-31 October). The dominant characteristics of the observation period were strong drought and drastically reduced pollutant emissions. Traffic and local sources operated at 0-10% of their capacities. Samples of dry and wet precipitation were taken by an automatic collector at a height of 2 m at weekly intervals. Two petri polycarbonate dishes of 93.5 mm diameter, facing upward, and one facing downward, were used for dry precipitation sampling. Determination in a `clean room` by differential pulse stripping voltammetry provided the low detection thresholds of 0.1, 1.0, 0.5 and 2.0 ng mL{sup -1}, i.e. the measurement of minimal dry deposition rates of 0.02, 0.2, 0.1 and 0.4 {mu}gm{sup -2}d{sup -1} for Cd, Pb, Cu and Zn, respectively. The mean annual deposition rates, expressed in {mu}g m{sup -2}d{sup -1}, were found to be as follows: 4.5 (down), 26 (up) and 37 (wet) for Pb, 2.1 (down), 13 (up) and 36(wet) for Cu, and 3.1 (down), 26 (up) and 95 (wet) for Zn. No values above 0.2 {mu}g m{sup -2}d{sup -1} were found for the Cd dry deposition rate and no Cd concentration higher than 1 ng mL{sup -1} for precipitation with an amount {gt} 0.5 mm at the weekly interval was detected. Using the XREDS method with a scanning electron microscope, Si, Al, Fe matrix elements and Mg, Ca, S, K, P, Cu, Zn, W, were identified as minor constituents of the single spherical particles and of the agglomerates present. Pb could not be categorized as a minor constituent of the coarse particles suspended in the air of New Belgrade on the basis of the previous analysis. Results of the analysis are given. 44 refs., 14 fig., 4 tabs.

  12. Current high-level waste solidification technology

    International Nuclear Information System (INIS)

    Bonner, W.F.; Ross, W.A.

    1976-01-01

    Technology has been developed in the U.S. and abroad for solidification of high-level waste from nuclear power production. Several processes have been demonstrated with actual radioactive waste and are now being prepared for use in the commercial nuclear industry. Conversion of the waste to a glass form is favored because of its high degree of nondispersibility and safety

  13. High-Level Application Framework for LCLS

    Energy Technology Data Exchange (ETDEWEB)

    Chu, P; Chevtsov, S.; Fairley, D.; Larrieu, C.; Rock, J.; Rogind, D.; White, G.; Zalazny, M.; /SLAC

    2008-04-22

    A framework for high level accelerator application software is being developed for the Linac Coherent Light Source (LCLS). The framework is based on plug-in technology developed by an open source project, Eclipse. Many existing functionalities provided by Eclipse are available to high-level applications written within this framework. The framework also contains static data storage configuration and dynamic data connectivity. Because the framework is Eclipse-based, it is highly compatible with any other Eclipse plug-ins. The entire infrastructure of the software framework will be presented. Planned applications and plug-ins based on the framework are also presented.

  14. Handbook of high-level radioactive waste transportation

    International Nuclear Information System (INIS)

    Sattler, L.R.

    1992-10-01

    The High-Level Radioactive Waste Transportation Handbook serves as a reference to which state officials and members of the general public may turn for information on radioactive waste transportation and on the federal government's system for transporting this waste under the Civilian Radioactive Waste Management Program. The Handbook condenses and updates information contained in the Midwestern High-Level Radioactive Waste Transportation Primer. It is intended primarily to assist legislators who, in the future, may be called upon to enact legislation pertaining to the transportation of radioactive waste through their jurisdictions. The Handbook is divided into two sections. The first section places the federal government's program for transporting radioactive waste in context. It provides background information on nuclear waste production in the United States and traces the emergence of federal policy for disposing of radioactive waste. The second section covers the history of radioactive waste transportation; summarizes major pieces of legislation pertaining to the transportation of radioactive waste; and provides an overview of the radioactive waste transportation program developed by the US Department of Energy (DOE). To supplement this information, a summary of pertinent federal and state legislation and a glossary of terms are included as appendices, as is a list of publications produced by the Midwestern Office of The Council of State Governments (CSG-MW) as part of the Midwestern High-Level Radioactive Waste Transportation Project

  15. A highly selective molecularly imprinted electrochemiluminescence sensor for ultra-trace beryllium detection

    International Nuclear Information System (INIS)

    Li, Jianping; Ma, Fei; Wei, Xiaoping; Fu, Cong; Pan, Hongcheng

    2015-01-01

    Graphical abstract: A novel molecular imprinted electrochemiluminescence sensor was fabricated for ultra-trace Be 2+ detection with an extremely lower detection limit based on the luminol–H 2 O 2 ECL system. - Highlights: • A novel molecular imprinted electrochemiluminescence sensor was fabricated for ultra-trace Be 2+ detection. • Imprint cavities in the MIPs from elution the Be–PAR complex could provide more recognition sites for analytes. • ECL emission produced by the luminol–H 2 O 2 ECL system, which was applied to detect Be 2+ . • It gave an extremely lower detection limit (2.35 × 10 −11 mol L −1 ) than the reported methods. - Abstract: A new molecularly imprinted electrochemiluminescence (ECL) sensor was proposed for highly sensitive and selective determination of ultratrace Be 2+ determination. The complex of Be 2+ with 4-(2-pyridylazo)-resorcinol (PAR) was chosen as the template molecule for the molecularly imprinted polymer (MIP). In this assay, the complex molecule could be eluted from the MIP, and the cavities formed could then selectively recognize the complex molecules. The cavities formed could also work as the tunnel for the transfer of probe molecules to produce sound responsive signal. The determination was based on the intensity of the signal, which was proportional to the concentrations of the complex molecule in the sample solution, and the Be 2+ concentration could then be determined indirectly. The results showed that in the range of 7 × 10 −11 mol L −1 to 8.0 × 10 −9 mol L −1 , the ECL intensity had a linear relationship with the Be 2+ concentrations, with the limit of detection of 2.35 × 10 −11 mol L −1 . This method was successfully used to detect Be 2+ in real water samples

  16. A Simplified Multipath Component Modeling Approach for High-Speed Train Channel Based on Ray Tracing

    Directory of Open Access Journals (Sweden)

    Jingya Yang

    2017-01-01

    Full Text Available High-speed train (HST communications at millimeter-wave (mmWave band have received a lot of attention due to their numerous high-data-rate applications enabling smart rail mobility. Accurate and effective channel models are always critical to the HST system design, assessment, and optimization. A distinctive feature of the mmWave HST channel is that it is rapidly time-varying. To depict this feature, a geometry-based multipath model is established for the dominant multipath behavior in delay and Doppler domains. Because of insufficient mmWave HST channel measurement with high mobility, the model is developed by a measurement-validated ray tracing (RT simulator. Different from conventional models, the temporal evolution of dominant multipath behavior is characterized by its geometry factor that represents the geometrical relationship of the dominant multipath component (MPC to HST environment. Actually, during each dominant multipath lifetime, its geometry factor is fixed. To statistically model the geometry factor and its lifetime, the dominant MPCs are extracted within each local wide-sense stationary (WSS region and are tracked over different WSS regions to identify its “birth” and “death” regions. Then, complex attenuation of dominant MPC is jointly modeled by its delay and Doppler shift both which are derived from its geometry factor. Finally, the model implementation is verified by comparison between RT simulated and modeled delay and Doppler spreads.

  17. Appending High-Resolution Elevation Data to GPS Speed Traces for Vehicle Energy Modeling and Simulation

    Energy Technology Data Exchange (ETDEWEB)

    Wood, E.; Burton, E.; Duran, A.; Gonder, J.

    2014-06-01

    Accurate and reliable global positioning system (GPS)-based vehicle use data are highly valuable for many transportation, analysis, and automotive considerations. Model-based design, real-world fuel economy analysis, and the growing field of autonomous and connected technologies (including predictive powertrain control and self-driving cars) all have a vested interest in high-fidelity estimation of powertrain loads and vehicle usage profiles. Unfortunately, road grade can be a difficult property to extract from GPS data with consistency. In this report, we present a methodology for appending high-resolution elevation data to GPS speed traces via a static digital elevation model. Anomalous data points in the digital elevation model are addressed during a filtration/smoothing routine, resulting in an elevation profile that can be used to calculate road grade. This process is evaluated against a large, commercially available height/slope dataset from the Navteq/Nokia/HERE Advanced Driver Assistance Systems product. Results will show good agreement with the Advanced Driver Assistance Systems data in the ability to estimate road grade between any two consecutive points in the contiguous United States.

  18. Estimation of {sup 60}Co activity in trace levels from aqueous medium using Ocimum basilicum seeds

    Energy Technology Data Exchange (ETDEWEB)

    Sangurdekar, P R [Radiation Safety System Div., Bhabha Atomic Research Centre, Mumbai (India); Melo, J S; D' Souza, S F [Nuclear Agriculture and Biotechnology Div., Bhabha Atomic Research Centre, Mumbai (India)

    2006-07-01

    In the field of pollution control besides the need for devising techniques for remediation, it is equally essential to develop alternative techniques for monitoring pollution levels including radioactivity. In this perspective, a simple technique is described for determining radioactivity in aqueous samples using O. basilicum seeds based on its property to adsorb radionuclides

  19. EAP high-level product architecture

    DEFF Research Database (Denmark)

    Guðlaugsson, Tómas Vignir; Mortensen, Niels Henrik; Sarban, Rahimullah

    2013-01-01

    EAP technology has the potential to be used in a wide range of applications. This poses the challenge to the EAP component manufacturers to develop components for a wide variety of products. Danfoss Polypower A/S is developing an EAP technology platform, which can form the basis for a variety...... of EAP technology products while keeping complexity under control. High level product architecture has been developed for the mechanical part of EAP transducers, as the foundation for platform development. A generic description of an EAP transducer forms the core of the high level product architecture...... the function of the EAP transducers to be changed, by basing the EAP transducers on a different combination of organ alternatives. A model providing an overview of the high level product architecture has been developed to support daily development and cooperation across development teams. The platform approach...

  20. Determination of trace level anions in reactor cooling water by ion chromatography using a resin of low capacity

    International Nuclear Information System (INIS)

    1988-01-01

    In the field of nuclear technology, IC has been found to be one of the most versatile and efficient analytical technique because of its ability to provide a fast and sensitive analysis of anions. In this work, a separater column packed with a resin of very low capacity was used with a concentration column for the determination of low level of anions present as traces in reactor cooling water. The results of retention times and detection limits were determined using 2.4 mM Na2CO3 / 3mM NaHCO3 mixture as eluent. The interferences of cations and anions such as (Ca)2+, (UO2)2+, (SO4)2+, have been investigated

  1. Levels, spatial variation and compartmentalization of trace elements in brown algae Cystoseira from marine protected areas of Crimea (Black Sea).

    Science.gov (United States)

    Kravtsova, Alexandra V; Milchakova, Nataliya A; Frontasyeva, Marina V

    2015-08-15

    Levels of Al, Sc, V, Co, Ni, As, Br, Rb, Sr, Ag, Sb, I, Cs, Ba, Th and U that were rarely or never studied, as well as the concentrations of classically investigated Mn, Fe and Zn in brown algae Cystoseira barbata C. Ag. and Cystoseira crinita (Desf.) Bory from the coastal waters of marine protected areas (Crimea, Black Sea), were determined using neutron activation analysis. Spatial variation and compartmentalization were studied for all 19 trace elements (TE). Concentrations of most TE were higher in "branches" than in "stems". Spatial variations of V, Co, Ni and Zn can be related to anthropogenic activities while Al, Sc, Fe, Rb, Cs, Th and U varied depending on chemical peculiarities of the coastal zone rocks. TE concentrations in C. crinita from marine protected areas near Tarkhankut peninsula and Cape Fiolent, identified as the most clean water areas, are submitted as the background concentrations. Copyright © 2015 Elsevier Ltd. All rights reserved.

  2. Determination of heavy metals at traces level in leached samples by energy dispersive x-ray fluorescence technique

    International Nuclear Information System (INIS)

    Simabuco, Silvana M.; Nascimento Filho, Virgilio F. do; Inacio, Graziela R.; Navarro, Angela N.

    1996-01-01

    In landfill solid residues are disposed in the soil. When made based on technical criteria and specifically operation patterns a safe confinement is warranted according to environmental and public health protection. However, when the disposal is made by a random and unsuitable way serious problems can be caused as groundwater and superficial water contamination through leach action, indicating the usefulness of monitoring landfills. In this way energy dispersive X-ray fluorescence analysis with radioisotopic excitation was applied to evaluate the concentrations of heavy metals at trace levels in leached samples from the Americana City Landfill with pre-concentration of the elements by a non-specific precipitating agent, called ammonium pyrrolidine dithiocarbamate (APDC). (author)

  3. Graphene/dodecanol floating solidification microextraction for the preconcentration of trace levels of cinnamic acid derivatives in traditional Chinese medicines.

    Science.gov (United States)

    Hu, Shuang; Yang, Xiao; Xue, Jiao; Chen, Xuan; Bai, Xiao-Hong; Yu, Zhi-Hui

    2017-07-01

    A novel graphene/dodecanol floating solidification microextraction followed by HPLC with diode-array detection has been developed to extract trace levels of four cinnamic acid derivatives in traditional Chinese medicines. Several parameters affecting the performance were investigated and optimized. Also, possible microextraction mechanism was analyzed and discussed. Under the optimum conditions (amount of graphene in dodecanol: 0.25 mg/mL; volume of extraction phase: 70 μL; pH of sample phase: 3; extraction time: 30   min; stirring rate: 1000 rpm; salt amount: 26.5% NaCl; volume of sample phase: 10 mL, and without dispersant addition), the enrichment factors of four cinnamic acid derivatives ranged from 26 to 112, the linear ranges were 1.0 × 10 -2 -10.0 μg/mL for caffeic acid, 1.3 × 10 -3 -1.9 μg/mL for p-hydroxycinnamic acid, 2.8 × 10 -3 -4.1 μg/mL for ferulic acid, and 2.7 × 10 -3 -4.1 μg/mL for cinnamic acid, with r 2 ≥ 0.9993. The detection limits were found to be in the range of 0.1-1.0 ng/mL, and satisfactory recoveries (92.5-111.2%) and precisions (RSDs 1.1-9.5%) were also achieved. The results showed that the approach is simple, effective and sensitive for the preconcentration and determination of trace levels of cinnamic acid derivatives in Chinese medicines. The proposed method was compared with conventional dodecanol floating solidification microextraction and other extraction methods. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. Identification case of evidence in timber tracing of Pinus radiate, using high-resolution melting (HRM) analysis.

    Science.gov (United States)

    Solano, Jaime; Anabalón, Leonardo; Encina, Francisco

    2016-03-01

    Fast, accurate detection of plant species and their hybrids using molecular tools will facilitate assessment and monitoring of timber tracing evidence. In this study the origin of unknown pine samples is determined for a case of timber theft in the region of Araucania southern Chile. We evaluate the utility of the trnL marker region for species identification applied to pine wood based on High Resolution Melting. This efficient tracing methods can be incorporated into forestry applications such as certification of origin. The object of this work was genotype identification using high-resolution melting (HRM) and trnL approaches for Pinus radiata (Don) in timber tracing evidence. Our results indicate that trnL is a very sensitive marker for delimiting species and HRM analysis was used successfully for genotyping Pinus samples for timber tracing purposes. Genotyping samples by HRM analysis with the trnL1 approach allowed us to differentiate two wood samples from the Pinaceae family: Pinus radiata (Don) and Pseudotsuga menziesii (Mirb.) Franco. The same approach with Pinus trnL wood was not able to discriminate between samples of Pinus radiata, indicating that the samples were genetically indistinguishable, possibly because they have the same genotype at this locus. Timber tracing with HRM analysis is expected to contribute to future forest certification schemes, control of illegal trading, and molecular traceability of Pinus spp. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  5. Trace species detection: Spectroscopy and molecular energy transfer at high temperature

    Energy Technology Data Exchange (ETDEWEB)

    Gray, J.A. [Sandia National Laboratories, Livermore, CA (United States)

    1993-12-01

    Monitoring the concentration of trace species such as atomic and molecular free radicals is essential in forming predictive models of combustion processes. LIF-based techniques have the necessary sensitivity for concentration and temperature measurements but have limited accuracy due to collisional quenching in combustion applications. The goal of this program is to use spectroscopic and kinetic measurements to quantify nonradiative and collisional effects on LIF signals and to develop new background-free alternatives to LIF. The authors have measured the natural linewidth of several OH A-X (3,0) rotational transitions to determine predissociation lifetimes in the upper state, which were presumed to be short compared to quenching lifetimes, and as a result, quantitative predictions about the applicability of predissociation fluorescence methods at high pressures are made. The authors are investigating collisional energy transfer in the A-state of NO. Quenching rates which enable direct corrections to NO LIF quantum yields at high temperature were calculations. These quenching rates are now being used in studies of turbulence/chemistry interactions. The authors have measured the electric dipole moment {mu} of excited-state NO using Stark quantum-beat spectroscopy. {mu} is an essential input to a harpoon model which predicts quenching efficiencies for NO (A) by a variety of combustion-related species. The authors are developing new coherent multiphoton techniques for measurements of atomic hydrogen concentration in laboratory flames to avoid the quenching problems associated with previous multiphoton LIF schemes.

  6. MEASUREMENT OF TRACE LEVELS OF DEUTERIUM OXIDE IN BIOLOGIC FLUIDS USING INFRARED SPECTROPHOTOMETRY.

    Science.gov (United States)

    Experimental data relevant to the assay of D2O in human serum, urine, and parotid fluid are presented. For serum, with triplicate scans, values of precision...and of accuracy of plus or minus 3% at the 250 p.p.m. D2O level are obtained. By use of parotid fluid the values are narrowed to plus or minus 2% at...aqueous compartments using values for serum water content. Parotid fluid appears to be particularly suitable for biomedical applications due to its ease

  7. Multi-trace elements level in drinking water and the prevalence of multi-chronic arsenical poisoning in residents in the west area of Iran

    International Nuclear Information System (INIS)

    Barati, A.H.; Maleki, A.; Alasvand, M.

    2010-01-01

    First, we determined the levels of 8 trace elements (As, Se, Hg, Cd, Ag, Mn, Cr and Pb) in 530 village drinking water sources by graphite furnace or flame atomic absorption spectroscopy method, in Kurdistan Province in the west of Iran. The results showed that the level of As, Cd and Se in 28 village drinking water sources exceeded WHO or National Standard limits. The levels of concentration of arsenic in drinking water ranged from 42 to 1500 μg/L. Then in a cross-sectional survey, 587 people from 211 households were chosen for clinical examinations of multi-chronic arsenical poisoning including pigment disorders, keratosis of palms and soles, Mee's line in fingers and nails and the gangrene as a systemic manifestation. Of 587 participants, 180 (30.7%) participants were affected by representing the type of chronic arsenical poisoning. The prevalence of Mee's line, keratosis, and pigment disorders were 86.1%, 77.2% and 67.8% respectively. Therefore, the prevalence of Mee's line between inhabitants was higher than the other disorders. The results show a strong linear relationship between arsenic exposure and occurrence of multi-chronic arsenical poisoning (R 2 = 0.76). The association between age for more than 40 years and gender for more than 60 years with chronic arsenical poisoning is significant (p < 0.05). Also, there is a relationship between subjects who were affected with disorders and duration of living in the village. Except for gangrene disorder, the odds ratio of prevalence of other disorders with arsenic exposure level in drinking water show a highly significant relationship between arsenic content and the risk of chronic disorders (p < 0.01). These results confirm the need to further study trace elements in drinking waters, food products and other samples in this area and the relationship to other chronic diseases arising out of arsenicosis.

  8. Multi-trace elements level in drinking water and the prevalence of multi-chronic arsenical poisoning in residents in the west area of Iran

    Energy Technology Data Exchange (ETDEWEB)

    Barati, A.H., E-mail: ah_barati@yahoo.com [Department of Medical Physics, Faculty of Medicine, Kurdistan University of Medical Sciences, P.O.Box-66135-756, Pasdaran Street, Sanandaj (Iran, Islamic Republic of); Maleki, A. [Department of Environmental Health, Faculty of Health Sciences, Kurdistan University of Medical Sciences, Sanandaj (Iran, Islamic Republic of); Alasvand, M. [Department of Medical Physiology, Faculty of Medicine, Kurdistan University of Medical Sciences, Sanandaj (Iran, Islamic Republic of)

    2010-03-01

    First, we determined the levels of 8 trace elements (As, Se, Hg, Cd, Ag, Mn, Cr and Pb) in 530 village drinking water sources by graphite furnace or flame atomic absorption spectroscopy method, in Kurdistan Province in the west of Iran. The results showed that the level of As, Cd and Se in 28 village drinking water sources exceeded WHO or National Standard limits. The levels of concentration of arsenic in drinking water ranged from 42 to 1500 {mu}g/L. Then in a cross-sectional survey, 587 people from 211 households were chosen for clinical examinations of multi-chronic arsenical poisoning including pigment disorders, keratosis of palms and soles, Mee's line in fingers and nails and the gangrene as a systemic manifestation. Of 587 participants, 180 (30.7%) participants were affected by representing the type of chronic arsenical poisoning. The prevalence of Mee's line, keratosis, and pigment disorders were 86.1%, 77.2% and 67.8% respectively. Therefore, the prevalence of Mee's line between inhabitants was higher than the other disorders. The results show a strong linear relationship between arsenic exposure and occurrence of multi-chronic arsenical poisoning (R{sup 2} = 0.76). The association between age for more than 40 years and gender for more than 60 years with chronic arsenical poisoning is significant (p < 0.05). Also, there is a relationship between subjects who were affected with disorders and duration of living in the village. Except for gangrene disorder, the odds ratio of prevalence of other disorders with arsenic exposure level in drinking water show a highly significant relationship between arsenic content and the risk of chronic disorders (p < 0.01). These results confirm the need to further study trace elements in drinking waters, food products and other samples in this area and the relationship to other chronic diseases arising out of arsenicosis.

  9. The management of high-level radioactive wastes

    International Nuclear Information System (INIS)

    Lennemann, Wm.L.

    1979-01-01

    The definition of high-level radioactive wastes is given. The following aspects of high-level radioactive wastes' management are discussed: fuel reprocessing and high-level waste; storage of high-level liquid waste; solidification of high-level waste; interim storage of solidified high-level waste; disposal of high-level waste; disposal of irradiated fuel elements as a waste

  10. High levels of uranium in groundwater of Ulaanbaatar, Mongolia

    Energy Technology Data Exchange (ETDEWEB)

    Nriagu, Jerome, E-mail: stoten@umich.edu [Department of Environmental Health Sciences, School of Public Health, University of Michigan, Ann Arbor, MI 48109 (United States); Nam, Dong-Ha; Ayanwola, Titilayo A. [Department of Environmental Health Sciences, School of Public Health, University of Michigan, Ann Arbor, MI 48109 (United States); Dinh, Hau [College of Literature, Science and Arts, University of Michigan (United States); Erdenechimeg, Erdenebayar; Ochir, Chimedsuren [Department Of Preventive Medicine, School Of Public Health, Health Science University, Mongolia, Ulaanbaatar (Mongolia); Bolormaa, Tsend-Ayush [Central Water Laboratory of Water Supply and Sewerage Authority (USUG), Ulaanbaatar (Mongolia)

    2012-01-01

    Water samples collected from 129 wells in seven of the nine sub-divisions of Ulaanbaatar were analyzed by inductively coupled plasma mass spectrometry (ICP-MS) using Clean Lab methods. The levels of many trace elements were found to be low with the average concentrations (ranges in brackets) being 0.9 (< 0.1-7.9) {mu}g/L for As; 7.7 (0.12-177) {mu}g/L for Mn; 0.2 (< 0.05-1.9) {mu}g/L for Co; 16 (< 0.1-686) {mu}g/L for Zn; 0.7 (< 0.1-1.8) {mu}g/L for Se; < 0.1 (< 0.02-0.69) {mu}g/L for Cd; and 1.3 (< 0.02-32) {mu}g/L for Pb. The levels of uranium were surprisingly elevated (mean, 4.6 {mu}g/L; range < 0.01-57 {mu}g/L), with the values for many samples exceeding the World Health Organization's guideline of 15 {mu}g/L for uranium in drinking water. Local rocks and soils appear to be the natural source of the uranium. The levels of uranium in Ulaanbaatar's groundwater are in the range that has been associated with nephrotoxicity, high blood pressure, bone dysfunction and likely reproductive impairment in human populations. We consider the risk associated with drinking the groundwater with elevated levels of uranium in Ulaanbaatar to be a matter for some public health concern and conclude that the paucity of data on chronic effects of low level exposure is a risk factor for continuing the injury to many people in this city. - Highlights: Black-Right-Pointing-Pointer We analyzed water samples from wells across the city of Ulaanbaatar, Mongolia for total uranium along with arsenic, manganese, cobalt, zinc, selenium, cadmium and lead. Black-Right-Pointing-Pointer We found that compared to other trace metals and metalloids, the levels of uranium were surprisingly elevated with the values for many samples exceeding the World Health Organization's guideline for drinking water. Black-Right-Pointing-Pointer Local rocks and soils appear to be the natural source of the uranium. Black-Right-Pointing-Pointer The health risk associated with drinking the groundwater

  11. HIGH LEVELS OF URANIUM IN GROUNDWATER OF ULAANBAATAR, MONGOLIA

    Science.gov (United States)

    Nriagu, Jerome; Nam, Dong-Ha; Ayanwola, Titilayo A.; Dinh, Hau; Erdenechimeg, Erdenebayar; Ochir, Chimedsuren; Bolormaa, Tsend-Ayush

    2011-01-01

    Water samples collected from 129 wells in seven of the nine sub-divisions of Ulaanbaatar were analyzed by inductively coupled plasma mass spectrometry (ICP-MS) using Clean Lab methods. The levels of many trace elements were found to be very low with the average concentrations (ranges in brackets) being 0.9 (uranium were surprisingly elevated (mean, 4.6 μg/L; range uranium in drinking water. Local rocks and soils appear to be the natural source of the uranium. The levels of uranium in Ulaanbaatar's groundwater are in the range that has been associated with nephrotoxicity, high blood pressure, bone dysfunction and likely reproductive impairment in human populations. We consider the risk associated with drinking the groundwater with elevated levels of uranium in Ulaanbaatar to be a matter for some public health concern and conclude that the paucity of data on chronic effects of low level exposure is a risk factor for continuing the injury to many people in this city. PMID:22142646

  12. High-level radioactive wastes. Supplement 1

    International Nuclear Information System (INIS)

    McLaren, L.H.

    1984-09-01

    This bibliography contains information on high-level radioactive wastes included in the Department of Energy's Energy Data Base from August 1982 through December 1983. These citations are to research reports, journal articles, books, patents, theses, and conference papers from worldwide sources. Five indexes, each preceded by a brief description, are provided: Corporate Author, Personal Author, Subject, Contract Number, and Report Number. 1452 citations

  13. PAIRWISE BLENDING OF HIGH LEVEL WASTE

    International Nuclear Information System (INIS)

    CERTA, P.J.

    2006-01-01

    The primary objective of this study is to demonstrate a mission scenario that uses pairwise and incidental blending of high level waste (HLW) to reduce the total mass of HLW glass. Secondary objectives include understanding how recent refinements to the tank waste inventory and solubility assumptions affect the mass of HLW glass and how logistical constraints may affect the efficacy of HLW blending

  14. Materials for high-level waste containment

    International Nuclear Information System (INIS)

    Marsh, G.P.

    1982-01-01

    The function of the high-level radioactive waste container in storage and of a container/overpack combination in disposal is considered. The consequent properties required from potential fabrication materials are discussed. The strategy adopted in selecting containment materials and the experimental programme underway to evaluate them are described. (U.K.)

  15. Effects of the interleukin-6 (IL-6) polymorphism on toxic metal and trace element levels in placental tissues

    International Nuclear Information System (INIS)

    Kayaalti, Zeliha; Tekin, Deniz; Aliyev, Vugar; Yalcin, Serap; Kurtay, Guelay; Soeylemezoglu, Tuelin

    2011-01-01

    The placenta is a crucial organ of fetal origin that functions in providing nutrients to the fetus from the mother. During pregnancy, the need for essential micronutrients, such as Fe and Zn, increases due to the requirements of the growing fetus. Maternal Fe deficiency induces an increase in Cu levels and can also affect cytokine levels in the placenta. On the other hand, Cu deficiency, although not as common, can also have destructive effects on the fetus. Interleukin-6 (IL-6) is a pleiotropic cytokine with a wide range of biological activities, including such as immune responses, acute-phase reactions, and inflammation. The placenta produces a significant amount of IL-6 during pregnancy. The effects of the IL-6 -174 G/C single nucleotide polymorphism (SNP) on IL-6 gene transcription and on plasma cytokine levels were assessed in the present study. We investigated the association between the IL-6 -174 G/C polymorphism and trace element/toxic metal levels in placental tissues. For the purposes of this study, 95 healthy volunteers were evaluated. Presence of the IL-6 polymorphism was determined using the standard polymerase chain reaction (PCR)-restriction fragment length polymorphism (RFLP) technique, and metal levels were analyzed by atomic absorption spectrometry (AAS). Based on our data, there were no significant associations between the IL-6 -174 G/C polymorphism and Pb, Cd, Fe, or Zn levels in the placental tissues (p > 0.05), but a statistically significant association was detected between the polymorphism and Cu levels (p = 0.016). We determined that the mean Cu levels in the placental tissues from individuals with GG, GC and CC genotypes were 5.62 ± 1.98, 6.22 ± 3.22 and 8.00 ± 1.32 ppm, respectively, whereas the overall mean Cu level from the placental tissues was 5.98 ± 2.51 ppm. - Highlights: → We studied between the association of IL-6 polymorphism and metal levels in the placenta tissues. → It was the first report evaluating the association

  16. Quantification of total aluminium concentrations in food samples at trace levels by INAA and PIGE methods

    International Nuclear Information System (INIS)

    Nanda, Braja B.; Acharya, R.

    2017-01-01

    Total aluminium contents in various food samples were determined by Instrumental Neutron Activation Analysis (INAA) and Particle Induced Gamma-ray Emission (PIGE) methods. A total of 16 rice samples, collected from the field, were analyzed by INAA using reactor neutrons from Dhruva reactor. Whereas a total 17 spices collected from market, were analyzed by both INAA and PIGE methods in conjunction with high resolution gamma-ray spectrometry. Aluminium concentration values were found to be in the range of 19-845 mg kg -1 for spices and 15-104 mg kg -1 for rice samples. The methods were validated by analyzing standard reference materials (SRMs) form NIST. (author)

  17. Selected maternal, fetal and placental trace element and heavy metal and maternal vitamin levels in preterm deliveries with or without preterm premature rupture of membranes.

    Science.gov (United States)

    Kucukaydin, Zehra; Kurdoglu, Mertihan; Kurdoglu, Zehra; Demir, Halit; Yoruk, Ibrahim H

    2018-01-25

    To compare maternal, fetal and placental trace element (magnesium, zinc and copper) and heavy metal (cadmium and lead) and maternal vitamin (retinol, α [alpha]-tocopherol, vitamin D 3 , 25-hydroxyvitamin D 3 and 1,25-dihydroxyvitamin D 3 ) levels in preterm deliveries with and without preterm premature rupture of membranes (PPROM). Sixty-eight patients giving birth preterm were grouped into preterm deliveries with PPROM (n = 35) and without PPROM (n = 33). Following delivery, maternal and umbilical cord blood sera and placental tissue samples were obtained. While magnesium, zinc, copper, cadmium and lead levels were measured in all samples, the levels of retinol, α-tocopherol, vitamin D 3 , 25-hydroxyvitamin D 3 and 1,25-dihydroxyvitamin D 3 were measured only in maternal serum. While magnesium level in maternal serum and zinc levels in both maternal and umbilical cord sera were lower, placental magnesium level was higher in preterm deliveries with PPROM (P 0.05). In preterm deliveries with PPROM, 25-hydroxyvitamin D 3 and retinol levels were higher, while vitamin D 3 and 1,25-dihydroxyvitamin D 3 levels were lower in maternal serum (P < 0.05). Maternal serum α-tocopherol levels were similar between the groups. Compared to spontaneous preterm births, PPROM is associated with low maternal serum together with high placental tissue magnesium and low maternal and umbilical cord sera zinc levels. Higher retinol and 25-hydroxyvitamin D 3 and lower vitamin D 3 and 1,25-dihydroxyvitamin D 3 maternal serum levels are also evident in these patients. © 2018 Japan Society of Obstetrics and Gynecology.

  18. High spin levels in 151Ho

    International Nuclear Information System (INIS)

    Gizon, J.; Gizon, A.; Andre, S.; Genevey, J.; Jastrzebski, J.; Kossakowski, R.; Moszinski, M.; Preibisz, Z.

    1981-02-01

    We report here on the first study of the level structure of 151 Ho. High spin levels in 151 Ho have been populated in the 141 Pr + 16 O and 144 Sm + 12 C reactions. The level structure has been established up to 6.6 MeV energy and the spins and particles determined up to 49/2 - . Most of the proposed level configurations can be explained by the coupling of hsub(11/2) protons to fsub(7/2) and/or hsub(9/2) neutrons. An isomer with 14 +- 3 ns half-life and a delayed gamma multiplicity equal to 17 +- 2 has been found. Its spin is larger than 57/2 h units

  19. Disposal of high-level radioactive waste

    International Nuclear Information System (INIS)

    Glasby, G.P.

    1977-01-01

    Although controversy surrounding the possible introduction of nuclear power into New Zealand has raised many points including radiation hazards, reactor safety, capital costs, sources of uranium and earthquake risks on the one hand versus energy conservation and alternative sources of energy on the other, one problem remains paramount and is of global significance - the storage and dumping of the high-level radioactive wastes of the reactor core. The generation of abundant supplies of energy now in return for the storage of these long-lived highly radioactive wastes has been dubbed the so-called Faustian bargain. This article discusses the growth of the nuclear industry and its implications to high-level waste disposal particularly in the deep-sea bed. (auth.)

  20. Children exposure to trace levels of heavy metals at the north zone of Kifissos River

    International Nuclear Information System (INIS)

    Evrenoglou, Lefkothea; Partsinevelou, Sofia Aikaterini; Stamatis, Panagiotis; Lazaris, Andreas; Patsouris, Eustratios; Kotampasi, Chrysanthi; Nicolopoulou-Stamati, Polyxeni

    2013-01-01

    This study evaluates the exposure level of primary school children at three different towns in northern Attica, near the banks of the Kifissos River, defining referential values of toxic heavy metals. Concentrations of five toxic metals (arsenic, cadmium, mercury, lead and nickel) were analyzed in water samples from the Kifissos River as well as in the scalp hair of children aged 11 to 12 years old living in the study area. Chronic low-level toxicity of lead and cadmium came into view in recent years as a problem of our civilization. Exposure to concentrations of arsenic (As), cadmium (Cd), mercury (Hg) and lead (Pb) poses a potential threat to humans and can cause effects on children's renal and dopaminergic systems without clear evidence of a threshold, a fact that reinforces the need to control all the potential heavy metal emissions into the environment in order to protect children's health. The results were analyzed with the IBM SPSS Statistics 20 for Windows. The possible influence of sex and area was examined. Statistical differences were observed by t-test between the log-transformed hair concentrations of lead (p = 0.021), arsenic (p = 0.016) and nickel (p = 0.038) in children's scalp hair from the municipalities of Kifisia and Kryoneri. ANOVA one-way test confirmed the difference of Pb concentration in hair between girls and boys from the municipality of Kifisia (p = 0.038). The t-test confirms the difference of heavy metal concentrations in river samples between the municipalities Kifisia and Philadelphia in comparison with the samples from Kryoneri. The observations suggest that children living at the municipality of Kifisia are exposed to higher concentrations of heavy metals than the others. Despite all the confounding factors, hair can be used as a biomarker in order to determine the exposure to heavy metals, according to standardized protocols. - Highlights: ► The study area was the north zone of the Kifissos River which is characterized by

  1. Children exposure to trace levels of heavy metals at the north zone of Kifissos River

    Energy Technology Data Exchange (ETDEWEB)

    Evrenoglou, Lefkothea [Department of Sanitary Engineering and Environmental Health, National School of Public Health, 11521 Athens (Greece); Partsinevelou, Sofia Aikaterini, E-mail: partsi@hol.gr [Department of Sanitary Engineering and Environmental Health, National School of Public Health, 11521 Athens (Greece); Stamatis, Panagiotis; Lazaris, Andreas; Patsouris, Eustratios; Kotampasi, Chrysanthi [Department of Pathology, Medical School of Athens,11527 Athens (Greece); Nicolopoulou-Stamati, Polyxeni, E-mail: pnicolopouloustamati@gmail.com [Department of Pathology, Medical School of Athens,11527 Athens (Greece)

    2013-01-15

    This study evaluates the exposure level of primary school children at three different towns in northern Attica, near the banks of the Kifissos River, defining referential values of toxic heavy metals. Concentrations of five toxic metals (arsenic, cadmium, mercury, lead and nickel) were analyzed in water samples from the Kifissos River as well as in the scalp hair of children aged 11 to 12 years old living in the study area. Chronic low-level toxicity of lead and cadmium came into view in recent years as a problem of our civilization. Exposure to concentrations of arsenic (As), cadmium (Cd), mercury (Hg) and lead (Pb) poses a potential threat to humans and can cause effects on children's renal and dopaminergic systems without clear evidence of a threshold, a fact that reinforces the need to control all the potential heavy metal emissions into the environment in order to protect children's health. The results were analyzed with the IBM SPSS Statistics 20 for Windows. The possible influence of sex and area was examined. Statistical differences were observed by t-test between the log-transformed hair concentrations of lead (p = 0.021), arsenic (p = 0.016) and nickel (p = 0.038) in children's scalp hair from the municipalities of Kifisia and Kryoneri. ANOVA one-way test confirmed the difference of Pb concentration in hair between girls and boys from the municipality of Kifisia (p = 0.038). The t-test confirms the difference of heavy metal concentrations in river samples between the municipalities Kifisia and Philadelphia in comparison with the samples from Kryoneri. The observations suggest that children living at the municipality of Kifisia are exposed to higher concentrations of heavy metals than the others. Despite all the confounding factors, hair can be used as a biomarker in order to determine the exposure to heavy metals, according to standardized protocols. - Highlights: ► The study area was the north zone of the Kifissos River which is

  2. Trace-level beryllium analysis in the laboratory and in the field: State of the art, challenges, and opportunities

    Energy Technology Data Exchange (ETDEWEB)

    BRISSON, MICHAEL

    2006-03-30

    Control of workplace exposure to beryllium is a growing issue in the United States and other nations. As the health risks associated with low-level exposure to beryllium are better understood, the need increases for improved analytical techniques both in the laboratory and in the field. These techniques also require a greater degree of standardization to permit reliable comparison of data obtained from different locations and at different times. Analysis of low-level beryllium samples, in the form of air filters or surface wipes, is frequently required for workplace monitoring or to provide data to support decision-making on implementation of exposure controls. In the United States and the United Kingdom, the current permissible exposure level is 2 {micro}g/m{sup 3} (air), and the United States Department of Energy has implemented an action level of 0.2 {micro}g/m{sup 3} (air) and 0.2 {micro}g/100 cm{sup 2} (surface). These low-level samples present a number of analytical challenges, including (1) a lack of suitable standard reference materials, (2) unknown robustness of sample preparation techniques, (3) interferences during analysis, (4) sensitivity (sufficiently low detection limits), (5) specificity (beryllium speciation), and (6) data comparability among laboratories. Additionally, there is a need for portable, real-time (or near real-time) equipment for beryllium air monitoring and surface wipe analysis that is both laboratory-validated and field-validated in a manner that would be accepted by national and/or international standards organizations. This paper provides a review of the current analytical requirements for trace-level beryllium analysis for worker protection, and also addresses issues that may change those requirements. The current analytical state of the art and relevant challenges facing the analytical community will be presented, followed by suggested criteria for real-time monitoring equipment. Recognizing and addressing these challenges will

  3. Rapid determination of trace level copper in tea infusion samples by solid contact ion selective electrode

    Directory of Open Access Journals (Sweden)

    Aysenur Birinci

    2016-07-01

    Full Text Available A new solid contact copper selective electrode with a poly (vinyl chloride (PVC membrane consisting of o-xylylenebis(N,N-diisobutyldithiocarbamate as ionophore has been prepared. The main novelties of constructed ion selective electrode concept are the enhanced robustness, cheapness, and fastness due to the use of solid contacts. The electrode exhibits a rapid (< 10 seconds and near-Nernstian response to Cu2+ activity from 10−1 to 10−6 mol/L at the pH range of 4.0–6.0. No serious interference from common ions was found. The electrode characterizes by high potential stability, reproducibility, and full repeatability. The electrode was used as an indicator electrode in potentiometric titration of Cu(II ions with EDTA and for the direct assay of tea infusion samples by means of the calibration graph technique. The results compared favorably with those obtained by the atomic absorption spectroscopy (AAS.

  4. Determination of trace element levels in leaves of Nerium oleander using X-Ray Fluorescence

    International Nuclear Information System (INIS)

    Santos, Ramon S.; Sanches, Francis A.C.R.A.; Neves, Arthur O.P.; Oliveira, Luis F.; Oliveira, Davi F.; Anjos, Marcelino J.

    2013-01-01

    The environmental pollution by human activity has been one of the most concerns in the last years, principally due to rapid urban growth in the cities and the industrialization process. The air pollution can be increased due to several different kinds of emissions: urban traffic, industrial activities, burning fuel, civil industry of construction/demolition, fires and natural phenomena. Many of these emissions move from long distances due to convections currents and finally tend to deposit mainly in the plants leaves and in the soil. Thus, the plants leaves works as a natural sampler by the emissions deposit in these ones. In this study Nerium oleander leaves were used to measure the environmental pollutions levels in different sampling urban regions in the city of Rio de Janeiro/RJ: Andarai, Benfica, Bonsucesso, Caju, Engenho de Dentro, Engenho Novo, Estacio, Grajau, Inhauma, Lins, Maracana, Maria da Graca, Meier, Praca da Bandeira, Riachuelo, Rio Comprido, Sao Cristovao, Tijuca, Vila Isabel and city Center. The control samples were collected in Campo Grande near of Parque Nacional da Pedra Branca/RJ (National Park of Pedra Branca/RJ). The leaves were collected from adult plants and after the collection the samples were cleaned and placed in the greenhouse for drying, then were mashed and pressed into tablets forms. The analyses were performed using the energy dispersion X-ray fluorescence (EDXRF), developed on the own laboratory and based in a SiPIN detector and a mini X ray tube. It was possible to detect 16 elements in the analyzed samples: K, Ca, Cr, Mn, Fe, Cu, Zn, Br, Rb, Sr, Ba and Pb. The results shows that, in the studied areas, the analysis of the Nerium oleander plant shows a low-cost option and with a substantial efficiency as an environmental pollution biomonitor. (author)

  5. Development of an on-line electrochemical analyser for trace level aluminium

    International Nuclear Information System (INIS)

    Chow, Christopher W.K.; Thomas, Shaun D.; Davey, David E.; Mulcahy, Dennis E.; Drikas, Mary

    2003-01-01

    An in-house designed computerised flow injection (FI) system for low-level aluminium analysis is examined. A simple, low cost electrochemical detection system has been implemented with computerised control and data acquisition system. The system consists of a commercial electrochemical analyser, FI components (manifold, pumps and valves) and an in-house designed control system to perform automated analysis. This system was developed to study aluminium speciation in water, particularly for drinking water. The analytical technique was based upon the complexation reaction between aluminium and a ligand--DASA (1,2-dihydroxy-anthraquinone-3-sulphonic acid). 'Labile' and total aluminium concentrations, Al labile and Al total , respectively, were determined by measuring the sample before and after UV irradiation by amperometry at +0.6 V. The limit of detection for this technique was 10 μg/l (0.37 μM) and the linear calibration range was up to 1.6 mg/l (60 μM) with r 2 value of 0.999. The Al labile /Al total ratios of the water treated by 40, 80 and 100 mg/l of alum using a laboratory scale pilot plant to simulate conventional drinking water treatment processes were found to be 0.4, 0.5 and 0.8, respectively. These results indicated that when higher alum dose was employed, the residual aluminium was present mostly as the 'labile' species. Whereas, if the treatment process was not running at its optimum condition (underdosing), a large portion of aluminium was present as natural organic matter (NOM) - aluminium complexes in the treated water. The system offers a practical and effective means of providing extended knowledge of residual aluminium in drinking water

  6. Determination of trace element levels in leaves of Nerium oleander using X-Ray Fluorescence

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Ramon S.; Sanches, Francis A.C.R.A.; Neves, Arthur O.P.; Oliveira, Luis F.; Oliveira, Davi F.; Anjos, Marcelino J. [Universidade do Estado do Rio de Janeiro (UERJ), Rio de Janeiro, RJ (Brazil). Inst. de Fisica Armando Dias Tavares. Dept. de Fisica Aplicada e Termodinamica

    2013-07-01

    The environmental pollution by human activity has been one of the most concerns in the last years, principally due to rapid urban growth in the cities and the industrialization process. The air pollution can be increased due to several different kinds of emissions: urban traffic, industrial activities, burning fuel, civil industry of construction/demolition, fires and natural phenomena. Many of these emissions move from long distances due to convections currents and finally tend to deposit mainly in the plants leaves and in the soil. Thus, the plants leaves works as a natural sampler by the emissions deposit in these ones. In this study Nerium oleander leaves were used to measure the environmental pollutions levels in different sampling urban regions in the city of Rio de Janeiro/RJ: Andarai, Benfica, Bonsucesso, Caju, Engenho de Dentro, Engenho Novo, Estacio, Grajau, Inhauma, Lins, Maracana, Maria da Graca, Meier, Praca da Bandeira, Riachuelo, Rio Comprido, Sao Cristovao, Tijuca, Vila Isabel and city Center. The control samples were collected in Campo Grande near of Parque Nacional da Pedra Branca/RJ (National Park of Pedra Branca/RJ). The leaves were collected from adult plants and after the collection the samples were cleaned and placed in the greenhouse for drying, then were mashed and pressed into tablets forms. The analyses were performed using the energy dispersion X-ray fluorescence (EDXRF), developed on the own laboratory and based in a SiPIN detector and a mini X ray tube. It was possible to detect 16 elements in the analyzed samples: K, Ca, Cr, Mn, Fe, Cu, Zn, Br, Rb, Sr, Ba and Pb. The results shows that, in the studied areas, the analysis of the Nerium oleander plant shows a low-cost option and with a substantial efficiency as an environmental pollution biomonitor. (author)

  7. Determination of trace impurities in high purity water by emission spectroscopy and flame photometry

    International Nuclear Information System (INIS)

    Charbel, M.Y.; Lordello, A.R.

    1985-01-01

    A spectrochemical method for the determination of trace amounts of Fe, Mg, Mn, Sn, Cr, Bi, Ni, Ca, Na, Zn, Sr, Al, Ba and Cu in high purity water is described. In addition Na, Li and K are measured by flame photometry. The standards used in the spectrochemical method are prepared by evaporation in hot plate of 50 mL standard solution in Teflon becker to dryness, the residue being dissolved with 500 μL hot HCl (1:1). Four hundred μL of this solution is evaporated under infra-red lamp on Apiezon treated flat top graphite electrodes. The residue is submitted to a direct current arc excitation. The accuracy is estimated by the spectrochemical method with a direct procedure sample preparation. The relative standard deviation varies from +- 4% to +- 27%. For the elements Na, Li and K standard solutions are concentrated fiftyfold by a simple evaporation procedure and then measured by flame photometry. The standard deviation and accuracy are given. (Author) [pt

  8. A compact high resolution ion mobility spectrometer for fast trace gas analysis.

    Science.gov (United States)

    Kirk, Ansgar T; Allers, Maria; Cochems, Philipp; Langejuergen, Jens; Zimmermann, Stefan

    2013-09-21

    Drift tube ion mobility spectrometers (IMS) are widely used for fast trace gas detection in air, but portable compact systems are typically very limited in their resolving power. Decreasing the initial ion packet width improves the resolution, but is generally associated with a reduced signal-to-noise-ratio (SNR) due to the lower number of ions injected into the drift region. In this paper, we present a refined theory of IMS operation which employs a combined approach for the analysis of the ion drift and the subsequent amplification to predict both the resolution and the SNR of the measured ion current peak. This theoretical analysis shows that the SNR is not a function of the initial ion packet width, meaning that compact drift tube IMS with both very high resolution and extremely low limits of detection can be designed. Based on these implications, an optimized combination of a compact drift tube with a length of just 10 cm and a transimpedance amplifier has been constructed with a resolution of 183 measured for the positive reactant ion peak (RIP(+)), which is sufficient to e.g. separate the RIP(+) from the protonated acetone monomer, even though their drift times only differ by a factor of 1.007. Furthermore, the limits of detection (LODs) for acetone are 180 pptv within 1 s of averaging time and 580 pptv within only 100 ms.

  9. Python based high-level synthesis compiler

    Science.gov (United States)

    Cieszewski, Radosław; Pozniak, Krzysztof; Romaniuk, Ryszard

    2014-11-01

    This paper presents a python based High-Level synthesis (HLS) compiler. The compiler interprets an algorithmic description of a desired behavior written in Python and map it to VHDL. FPGA combines many benefits of both software and ASIC implementations. Like software, the mapped circuit is flexible, and can be reconfigured over the lifetime of the system. FPGAs therefore have the potential to achieve far greater performance than software as a result of bypassing the fetch-decode-execute operations of traditional processors, and possibly exploiting a greater level of parallelism. Creating parallel programs implemented in FPGAs is not trivial. This article describes design, implementation and first results of created Python based compiler.

  10. The CMS High-Level Trigger

    International Nuclear Information System (INIS)

    Covarelli, R.

    2009-01-01

    At the startup of the LHC, the CMS data acquisition is expected to be able to sustain an event readout rate of up to 100 kHz from the Level-1 trigger. These events will be read into a large processor farm which will run the 'High-Level Trigger'(HLT) selection algorithms and will output a rate of about 150 Hz for permanent data storage. In this report HLT performances are shown for selections based on muons, electrons, photons, jets, missing transverse energy, τ leptons and b quarks: expected efficiencies, background rates and CPU time consumption are reported as well as relaxation criteria foreseen for a LHC startup instantaneous luminosity.

  11. The CMS High-Level Trigger

    CERN Document Server

    Covarelli, Roberto

    2009-01-01

    At the startup of the LHC, the CMS data acquisition is expected to be able to sustain an event readout rate of up to 100 kHz from the Level-1 trigger. These events will be read into a large processor farm which will run the "High-Level Trigger" (HLT) selection algorithms and will output a rate of about 150 Hz for permanent data storage. In this report HLT performances are shown for selections based on muons, electrons, photons, jets, missing transverse energy, tau leptons and b quarks: expected efficiencies, background rates and CPU time consumption are reported as well as relaxation criteria foreseen for a LHC startup instantaneous luminosity.

  12. The CMS High-Level Trigger

    Science.gov (United States)

    Covarelli, R.

    2009-12-01

    At the startup of the LHC, the CMS data acquisition is expected to be able to sustain an event readout rate of up to 100 kHz from the Level-1 trigger. These events will be read into a large processor farm which will run the "High-Level Trigger" (HLT) selection algorithms and will output a rate of about 150 Hz for permanent data storage. In this report HLT performances are shown for selections based on muons, electrons, photons, jets, missing transverse energy, τ leptons and b quarks: expected efficiencies, background rates and CPU time consumption are reported as well as relaxation criteria foreseen for a LHC startup instantaneous luminosity.

  13. High-level waste processing and disposal

    International Nuclear Information System (INIS)

    Crandall, J.L.; Krause, H.; Sombret, C.; Uematsu, K.

    1984-01-01

    The national high-level waste disposal plans for France, the Federal Republic of Germany, Japan, and the United States are covered. Three conclusions are reached. The first conclusion is that an excellent technology already exists for high-level waste disposal. With appropriate packaging, spent fuel seems to be an acceptable waste form. Borosilicate glass reprocessing waste forms are well understood, in production in France, and scheduled for production in the next few years in a number of other countries. For final disposal, a number of candidate geological repository sites have been identified and several demonstration sites opened. The second conclusion is that adequate financing and a legal basis for waste disposal are in place in most countries. Costs of high-level waste disposal will probably add about 5 to 10% to the costs of nuclear electric power. The third conclusion is less optimistic. Political problems remain formidable in highly conservative regulations, in qualifying a final disposal site, and in securing acceptable transport routes

  14. Extractive scintillating polymer sensors for trace-level detection of uranium in contaminated ground water

    International Nuclear Information System (INIS)

    Duval, Christine E.; DeVol, Timothy A.; Husson, Scott M.

    2016-01-01

    This contribution describes the synthesis of robust extractive scintillating resin and its use in a flow-cell detector for the direct detection of uranium in environmental waters. The base poly[(4-methyl styrene)-co-(4-vinylbenzyl chloride)-co-(divinylbenzene)-co-(2-(1-napthyl)-4-vinyl-5-phenyloxazole)] resin contains covalently bound fluorophores. Uranium-binding functionality was added to the resin by an Arbuzov reaction followed by hydrolysis via strong acid or trimethylsilyl bromide (TMSBr)-mediated methanolysis. The resin was characterized by Fourier-transform infrared spectroscopy and spectrofluorometry. Fluorophore degradation was observed in the resin hydrolyzed by strong acid, while the resin hydrolyzed by TMSBr-mediated methanolysis maintained luminosity and showed hydrogen bonding-induced Stokes' shift of ∼100 nm. The flow cell detection efficiency for uranium of the TMSBr-mediated methanolysis resin was evaluated at pH 4, 5 and 6 in DI water containing 500 Bq L"−"1 uranium-233 and demonstrated flow cell detection efficiencies of 23%, 16% and 7%. Experiments with pH 4, synthetic groundwater with 50 Bq L"−"1 uranium-233 exhibited a flow cell detection efficiency of 17%. The groundwater measurements show that the resins can concentrate the uranyl cation from waters with high concentrations of competitor ions at near-neutral pH. Findings from this research will lay the groundwork for development of materials for real-time environmental sensing of alpha- and beta-emitting radionuclides. - Highlights: • Extractive scintillating resins synthesized with covalently bound fluor and ligand. • Methylphosphonic acid-derivitized resins characterized for optical properties. • Online detection of uranium in ground water demonstrated at near-neutral pH.

  15. Extractive scintillating polymer sensors for trace-level detection of uranium in contaminated ground water

    Energy Technology Data Exchange (ETDEWEB)

    Duval, Christine E. [Department of Chemical and Biomolecular Engineering, Clemson University, 127 Earle Hall, Clemson, SC 29634 (United States); DeVol, Timothy A. [Department of Environmental Engineering and Earth Sciences, Clemson University, 342 Computer Court, Anderson, SC 29625 (United States); Husson, Scott M., E-mail: shusson@clemson.edu [Department of Chemical and Biomolecular Engineering, Clemson University, 127 Earle Hall, Clemson, SC 29634 (United States)

    2016-12-01

    This contribution describes the synthesis of robust extractive scintillating resin and its use in a flow-cell detector for the direct detection of uranium in environmental waters. The base poly[(4-methyl styrene)-co-(4-vinylbenzyl chloride)-co-(divinylbenzene)-co-(2-(1-napthyl)-4-vinyl-5-phenyloxazole)] resin contains covalently bound fluorophores. Uranium-binding functionality was added to the resin by an Arbuzov reaction followed by hydrolysis via strong acid or trimethylsilyl bromide (TMSBr)-mediated methanolysis. The resin was characterized by Fourier-transform infrared spectroscopy and spectrofluorometry. Fluorophore degradation was observed in the resin hydrolyzed by strong acid, while the resin hydrolyzed by TMSBr-mediated methanolysis maintained luminosity and showed hydrogen bonding-induced Stokes' shift of ∼100 nm. The flow cell detection efficiency for uranium of the TMSBr-mediated methanolysis resin was evaluated at pH 4, 5 and 6 in DI water containing 500 Bq L{sup −1} uranium-233 and demonstrated flow cell detection efficiencies of 23%, 16% and 7%. Experiments with pH 4, synthetic groundwater with 50 Bq L{sup −1} uranium-233 exhibited a flow cell detection efficiency of 17%. The groundwater measurements show that the resins can concentrate the uranyl cation from waters with high concentrations of competitor ions at near-neutral pH. Findings from this research will lay the groundwork for development of materials for real-time environmental sensing of alpha- and beta-emitting radionuclides. - Highlights: • Extractive scintillating resins synthesized with covalently bound fluor and ligand. • Methylphosphonic acid-derivitized resins characterized for optical properties. • Online detection of uranium in ground water demonstrated at near-neutral pH.

  16. Extractive scintillating polymer sensors for trace-level detection of uranium in contaminated ground water.

    Science.gov (United States)

    Duval, Christine E; DeVol, Timothy A; Husson, Scott M

    2016-12-01

    This contribution describes the synthesis of robust extractive scintillating resin and its use in a flow-cell detector for the direct detection of uranium in environmental waters. The base poly[(4-methyl styrene)-co-(4-vinylbenzyl chloride)-co-(divinylbenzene)-co-(2-(1-napthyl)-4-vinyl-5-phenyloxazole)] resin contains covalently bound fluorophores. Uranium-binding functionality was added to the resin by an Arbuzov reaction followed by hydrolysis via strong acid or trimethylsilyl bromide (TMSBr)-mediated methanolysis. The resin was characterized by Fourier-transform infrared spectroscopy and spectrofluorometry. Fluorophore degradation was observed in the resin hydrolyzed by strong acid, while the resin hydrolyzed by TMSBr-mediated methanolysis maintained luminosity and showed hydrogen bonding-induced Stokes' shift of ∼100 nm. The flow cell detection efficiency for uranium of the TMSBr-mediated methanolysis resin was evaluated at pH 4, 5 and 6 in DI water containing 500 Bq L -1 uranium-233 and demonstrated flow cell detection efficiencies of 23%, 16% and 7%. Experiments with pH 4, synthetic groundwater with 50 Bq L -1 uranium-233 exhibited a flow cell detection efficiency of 17%. The groundwater measurements show that the resins can concentrate the uranyl cation from waters with high concentrations of competitor ions at near-neutral pH. Findings from this research will lay the groundwork for development of materials for real-time environmental sensing of alpha- and beta-emitting radionuclides. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. DUACS: Toward High Resolution Sea Level Products

    Science.gov (United States)

    Faugere, Y.; Gerald, D.; Ubelmann, C.; Claire, D.; Pujol, M. I.; Antoine, D.; Desjonqueres, J. D.; Picot, N.

    2016-12-01

    The DUACS system produces, as part of the CNES/SALP project, and the Copernicus Marine Environment and Monitoring Service, high quality multimission altimetry Sea Level products for oceanographic applications, climate forecasting centers, geophysic and biology communities... These products consist in directly usable and easy to manipulate Level 3 (along-track cross-calibrated SLA) and Level 4 products (multiple sensors merged as maps or time series) and are available in global and regional version (Mediterranean Sea, Arctic, European Shelves …).The quality of the products is today limited by the altimeter technology "Low Resolution Mode" (LRM), and the lack of available observations. The launch of 2 new satellites in 2016, Jason-3 and Sentinel-3A, opens new perspectives. Using the global Synthetic Aperture Radar mode (SARM) coverage of S3A and optimizing the LRM altimeter processing (retracking, editing, ...) will allow us to fully exploit the fine-scale content of the altimetric missions. Thanks to this increase of real time altimetry observations we will also be able to improve Level-4 products by combining these new Level-3 products and new mapping methodology, such as dynamic interpolation. Finally these improvements will benefit to downstream products : geostrophic currents, Lagrangian products, eddy atlas… Overcoming all these challenges will provide major upgrades of Sea Level products to better fulfill user needs.

  18. Atmospheric pollution for trace elements in the remote high-altitude atmosphere in central Asia as recorded in snow from Mt. Qomolangma (Everest) of the Himalayas.

    Science.gov (United States)

    Lee, Khanghyun; Hur, Soon Do; Hou, Shugui; Hong, Sungmin; Qin, Xiang; Ren, Jiawen; Liu, Yapping; Rosman, Kevin J R; Barbante, Carlo; Boutron, Claude F

    2008-10-01

    A series of 42 snow samples covering over a one-year period from the fall of 2004 to the summer of 2005 were collected from a 2.1-m snow pit at a high-altitude site on the northeastern slope of Mt. Everest. These samples were analyzed for Al, V, Cr, Mn, Co, Ni, Cu, Zn, As, Rb, Sr, Cd, Sb, Pb, and Bi in order to characterize the relative contributions from anthropogenic and natural sources to the fallout of these elements in central Himalayas. Our data were also considered in the context of monsoon versus non-monsoon seasons. The mean concentrations of the majority of the elements were determined to be at the pg g(-1) level with a strong variation in concentration with snow depth. While the mean concentrations of most of the elements were significantly higher during the non-monsoon season than during the monsoon season, considerable variability in the trace element inputs to the snow was observed during both periods. Cu, Zn, As, Cd, Sb, and Bi displayed high crustal enrichment factors (EFc) in most samples, while Cr, Ni, Rb, and Pb show high EFc values in some of the samples. Our data indicate that anthropogenic inputs are potentially important for these elements in the remote high-altitude atmosphere in the central Himalayas. The relationship between the EFc of each element and the Al concentration indicates that a dominant input of anthropogenic trace elements occurs during both the monsoon and non-monsoon seasons, when crustal contribution is relatively minor. Finally, a comparison of the trace element fallout fluxes calculated in our samples with those recently obtained at Mont Blanc, Greenland, and Antarctica provides direct evidence for a geographical gradient of the atmospheric pollution with trace elements on a global scale.

  19. Cermets for high level waste containment

    International Nuclear Information System (INIS)

    Aaron, W.S.; Quinby, T.C.; Kobisk, E.H.

    1978-01-01

    Cermet materials are currently under investigation as an alternate for the primary containment of high level wastes. The cermet in this study is an iron--nickel base metal matrix containing uniformly dispersed, micron-size fission product oxides, aluminosilicates, and titanates. Cermets possess high thermal conductivity, and typical waste loading of 70 wt % with volume reduction factors of 2 to 200 and low processing volatility losses have been realized. Preliminary leach studies indicate a leach resistance comparable to other candidate waste forms; however, more quantitative data are required. Actual waste studies have begun on NFS Acid Thorex, SRP dried sludge and fresh, unneutralized SRP process wastes

  20. Timing of High-level Waste Disposal

    International Nuclear Information System (INIS)

    2008-01-01

    This study identifies key factors influencing the timing of high-level waste (HLW) disposal and examines how social acceptability, technical soundness, environmental responsibility and economic feasibility impact on national strategies for HLW management and disposal. Based on case study analyses, it also presents the strategic approaches adopted in a number of national policies to address public concerns and civil society requirements regarding long-term stewardship of high-level radioactive waste. The findings and conclusions of the study confirm the importance of informing all stakeholders and involving them in the decision-making process in order to implement HLW disposal strategies successfully. This study will be of considerable interest to nuclear energy policy makers and analysts as well as to experts in the area of radioactive waste management and disposal. (author)

  1. High-Level Waste Melter Study Report

    Energy Technology Data Exchange (ETDEWEB)

    Perez, Joseph M.; Bickford, Dennis F.; Day, Delbert E.; Kim, Dong-Sang; Lambert, Steven L.; Marra, Sharon L.; Peeler, David K.; Strachan, Denis M.; Triplett, Mark B.; Vienna, John D.; Wittman, Richard S.

    2001-07-13

    At the Hanford Site in Richland, Washington, the path to site cleanup involves vitrification of the majority of the wastes that currently reside in large underground tanks. A Joule-heated glass melter is the equipment of choice for vitrifying the high-level fraction of these wastes. Even though this technology has general national and international acceptance, opportunities may exist to improve or change the technology to reduce the enormous cost of accomplishing the mission of site cleanup. Consequently, the U.S. Department of Energy requested the staff of the Tanks Focus Area to review immobilization technologies, waste forms, and modifications to requirements for solidification of the high-level waste fraction at Hanford to determine what aspects could affect cost reductions with reasonable long-term risk. The results of this study are summarized in this report.

  2. Comparative study on serum levels of macro and trace elements in schizophrenia based on supervised learning methods.

    Science.gov (United States)

    Lin, Tong; Liu, Tiebing; Lin, Yucheng; Yan, Lailai; Chen, Zhongxue; Wang, Jingyu

    2017-09-01

    The etiology and pathophysiology of schizophrenia (SCZ) remain obscure. This study explored the associations between SCZ risk and serum levels of 39 macro and trace elements (MTE). A 1:1 matched case-control study was conducted among 114 schizophrenia patients and 114 healthy controls matched by age, sex and region. Blood samples were collected to determine the concentrations of 39 MTE by ICP-AES and ICP-MS. Both supervised learning methods and classical statistical testing were used to uncover the difference of MTE levels between cases and controls. The best prediction accuracies were 99.21% achieved by support vector machines in the original feature space (without dimensionality reduction), and 98.82% achieved by Naive Bayes with dimensionality reduction. More than half of MTE were found to be significantly different between SCZ patients and the controls. The presented investigation showed that there existed remarkable differences in concentrations of MTE between SCZ patients and healthy controls. The results of this study might be useful to diagnosis and prognosis of SCZ; they also indicated other promising applications in pharmacy and nutrition. However, the results should be interpreted with caution due to limited sample size and the lack of potential confounding factors, such as alcohol, smoking, body mass index (BMI), use of antipsychotics and dietary intakes. In the future the application of the analyses will be useful in designs that have larger sample sizes. Copyright © 2017 Elsevier GmbH. All rights reserved.

  3. High-level radioactive wastes. Supplement 1

    Energy Technology Data Exchange (ETDEWEB)

    McLaren, L.H. (ed.)

    1984-09-01

    This bibliography contains information on high-level radioactive wastes included in the Department of Energy's Energy Data Base from August 1982 through December 1983. These citations are to research reports, journal articles, books, patents, theses, and conference papers from worldwide sources. Five indexes, each preceded by a brief description, are provided: Corporate Author, Personal Author, Subject, Contract Number, and Report Number. 1452 citations.

  4. Decommissioning high-level waste surface facilities

    International Nuclear Information System (INIS)

    1978-04-01

    The protective storage, entombment and dismantlement options of decommissioning a High-Level Waste Surface Facility (HLWSF) was investigated. A reference conceptual design for the facility was developed based on the designs of similar facilities. State-of-the-art decommissioning technologies were identified. Program plans and cost estimates for decommissioning the reference conceptual designs were developed. Good engineering design concepts were on the basis of this work identified

  5. The ALICE Dimuon Spectrometer High Level Trigger

    CERN Document Server

    Becker, B; Cicalo, Corrado; Das, Indranil; de Vaux, Gareth; Fearick, Roger; Lindenstruth, Volker; Marras, Davide; Sanyal, Abhijit; Siddhanta, Sabyasachi; Staley, Florent; Steinbeck, Timm; Szostak, Artur; Usai, Gianluca; Vilakazi, Zeblon

    2009-01-01

    The ALICE Dimuon Spectrometer High Level Trigger (dHLT) is an on-line processing stage whose primary function is to select interesting events that contain distinct physics signals from heavy resonance decays such as J/psi and Gamma particles, amidst unwanted background events. It forms part of the High Level Trigger of the ALICE experiment, whose goal is to reduce the large data rate of about 25 GB/s from the ALICE detectors by an order of magnitude, without loosing interesting physics events. The dHLT has been implemented as a software trigger within a high performance and fault tolerant data transportation framework, which is run on a large cluster of commodity compute nodes. To reach the required processing speeds, the system is built as a concurrent system with a hierarchy of processing steps. The main algorithms perform partial event reconstruction, starting with hit reconstruction on the level of the raw data received from the spectrometer. Then a tracking algorithm finds track candidates from the recon...

  6. Resonance phenomena at high level density

    International Nuclear Information System (INIS)

    Sobeslavsky, E.; Dittes, F.M.; Rotter, I.; Technische Univ. Dresden

    1994-11-01

    We investigate the behaviour of resonances as a function of the coupling strength between bound and unbound states on the basis of a simple S-matrix model. Resonance energies and widths are calculated for well isolated, overlapping and strongly overlapping resonance states. The formation of shorter and longer time scales (trapping effect) is traced. We illustrate that the cross section results from an interference of all resonance states in spite of the fact that their lifetimes may be very different. (orig.)

  7. Performance of the CMS High Level Trigger

    CERN Document Server

    Perrotta, Andrea

    2015-01-01

    The CMS experiment has been designed with a 2-level trigger system. The first level is implemented using custom-designed electronics. The second level is the so-called High Level Trigger (HLT), a streamlined version of the CMS offline reconstruction software running on a computer farm. For Run II of the Large Hadron Collider, the increases in center-of-mass energy and luminosity will raise the event rate to a level challenging for the HLT algorithms. The increase in the number of interactions per bunch crossing, on average 25 in 2012, and expected to be around 40 in Run II, will be an additional complication. We present here the expected performance of the main triggers that will be used during the 2015 data taking campaign, paying particular attention to the new approaches that have been developed to cope with the challenges of the new run. This includes improvements in HLT electron and photon reconstruction as well as better performing muon triggers. We will also present the performance of the improved trac...

  8. The high level vibration test program

    International Nuclear Information System (INIS)

    Hofmayer, C.H.; Curreri, J.R.; Park, Y.J.; Kato, W.Y.; Kawakami, S.

    1989-01-01

    As part of cooperative agreements between the US and Japan, tests have been performed on the seismic vibration table at the Tadotsu Engineering Laboratory of Nuclear Power Engineering Test Center (NUPEC) in Japan. The objective of the test program was to use the NUPEC vibration table to drive large diameter nuclear power piping to substantial plastic strain with an earthquake excitation and to compare the results with state-of-the-art analysis of the problem. The test model was subjected to a maximum acceleration well beyond what nuclear power plants are designed to withstand. A modified earthquake excitation was applied and the excitation level was increased carefully to minimize the cumulative fatigue damage due to the intermediate level excitations. Since the piping was pressurized, and the high level earthquake excitation was repeated several times, it was possible to investigate the effects of ratchetting and fatigue as well. Elastic and inelastic seismic response behavior of the test model was measured in a number of test runs with an increasing excitation input level up to the limit of the vibration table. In the maximum input condition, large dynamic plastic strains were obtained in the piping. Crack initiation was detected following the second maximum excitation run. Crack growth was carefully monitored during the next two additional maximum excitation runs. The final test resulted in a maximum crack depth of approximately 94% of the wall thickness. The HLVT (high level vibration test) program has enhanced understanding of the behavior of piping systems under severe earthquake loading. As in other tests to failure of piping components, it has demonstrated significant seismic margin in nuclear power plant piping

  9. Ramifications of defining high-level waste

    International Nuclear Information System (INIS)

    Wood, D.E.; Campbell, M.H.; Shupe, M.W.

    1987-01-01

    The Nuclear Regulatory Commission (NRC) is considering rule making to provide a concentration-based definition of high-level waste (HLW) under authority derived from the Nuclear Waste Policy Act (NWPA) of 1982 and the Low Level Waste Policy Amendments Act of 1985. The Department of Energy (DOE), which has the responsibility to dispose of certain kinds of commercial waste, is supporting development of a risk-based classification system by the Oak Ridge National Laboratory to assist in developing and implementing the NRC rule. The system is two dimensional, with the axes based on the phrases highly radioactive and requires permanent isolation in the definition of HLW in the NWPA. Defining HLW will reduce the ambiguity in the present source-based definition by providing concentration limits to establish which materials are to be called HLW. The system allows the possibility of greater-confinement disposal for some wastes which do not require the degree of isolation provided by a repository. The definition of HLW will provide a firm basis for waste processing options which involve partitioning of waste into a high-activity stream for repository disposal, and a low-activity stream for disposal elsewhere. Several possible classification systems have been derived and the characteristics of each are discussed. The Defense High Level Waste Technology Lead Office at DOE - Richland Operations Office, supported by Rockwell Hanford Operations, has coordinated reviews of the ORNL work by a technical peer review group and other DOE offices. The reviews produced several recommendations and identified several issues to be addressed in the NRC rule making. 10 references, 3 figures

  10. TRACING THE LOWEST PROPELLER LINE IN MAGELLANIC HIGH-MASS X-RAY BINARIES

    Energy Technology Data Exchange (ETDEWEB)

    Christodoulou, Dimitris M.; Laycock, Silas G. T.; Yang, Jun; Fingerman, Samuel, E-mail: dimitris_christodoulou@uml.edu, E-mail: silas_laycock@uml.edu, E-mail: jun_yang@uml.edu, E-mail: fingerman.samuel@gmail.com [Lowell Center for Space Science and Technology, 600 Suffolk Street, Lowell, MA 01854 (United States)

    2016-09-20

    We have combined the published observations of high-mass X-ray binary (HMXB) pulsars in the Magellanic Clouds with a new processing of the complete archival data sets from the XMM-Newton and Chandra observatories in an attempt to trace the lowest propeller line below which accretion to polar caps is inhibited by the centrifugal force and the pulsations from the most weakly magnetized pulsars cease. Previously published data reveal that some of the faster-spinning pulsars with spin periods of P {sub S} < 12 s, detected at relatively low X-ray luminosities L {sub X} , appear to define such a line in the P {sub S} – L {sub X} diagram, characterized by a magnetic moment of μ = 3 × 10{sup 29} G cm{sup 3}. This value implies the presence of surface magnetic fields of B ≥ 3 × 10{sup 11} G in the compact objects of this class. Only a few quiescent HMXBs are found below the propeller line: LXP4.40 and SXP4.78, for which XMM-Newton and Chandra null detections respectively placed firm upper limits on their X-ray fluxes in deep quiescence; and A0538-66, for which many sub-Eddington detections have never measured any pulsations. On the other hand, the data from the XMM-Newton and Chandra archives show clearly that, during routine observation cycles, several sources have been detected below the propeller line in extremely faint, nonpulsating states that can be understood as the result of weak magnetospheric emission when accretion to the poles is centrifugally stalled or severely diminished. We also pay attention to the anomalous X-ray pulsar CXOU J010043.1-721134 that was reported in HMXB surveys. Its pulsations and locations near and above the propeller line indicate that this pulsar could be accreting from a fossil disk.

  11. Intergenerational ethics of high level radioactive waste

    Energy Technology Data Exchange (ETDEWEB)

    Takeda, Kunihiko [Nagoya Univ., Graduate School of Engineering, Nagoya, Aichi (Japan); Nasu, Akiko; Maruyama, Yoshihiro [Shibaura Inst. of Tech., Tokyo (Japan)

    2003-03-01

    The validity of intergenerational ethics on the geological disposal of high level radioactive waste originating from nuclear power plants was studied. The result of the study on geological disposal technology showed that the current method of disposal can be judged to be scientifically reliable for several hundred years and the radioactivity level will be less than one tenth of the tolerable amount after 1,000 years or more. This implies that the consideration of intergenerational ethics of geological disposal is meaningless. Ethics developed in western society states that the consent of people in the future is necessary if the disposal has influence on them. Moreover, the ethics depends on generally accepted ideas in western society and preconceptions based on racism and sexism. The irrationality becomes clearer by comparing the dangers of the exhaustion of natural resources and pollution from harmful substances in a recycling society. (author)

  12. Management of high level radioactive waste

    International Nuclear Information System (INIS)

    Redon, A.; Mamelle, J.; Chambon, M.

    1977-01-01

    The world wide needs in reprocessing will reach the value of 10.000 t/y of irradiated fuels, in the mid of the 80's. Several countries will have planned, in their nuclear programme, the construction of reprocessing plants with a 1500 t/y capacity, corresponding to 50.000 MWe installed. At such a level, the solidification of the radioactive waste will become imperative. For this reason, all efforts, in France, have been directed towards the realization of industrial plants able of solidifying the fission products as a glassy material. The advantages of this decision, and the reasons for it are presented. The continuing development work, and the conditions and methods of storing the high-level wastes prior to solidification, and of the interim storage (for thermal decay) and the ultimate disposal after solidification are described [fr

  13. Intergenerational ethics of high level radioactive waste

    International Nuclear Information System (INIS)

    Takeda, Kunihiko; Nasu, Akiko; Maruyama, Yoshihiro

    2003-01-01

    The validity of intergenerational ethics on the geological disposal of high level radioactive waste originating from nuclear power plants was studied. The result of the study on geological disposal technology showed that the current method of disposal can be judged to be scientifically reliable for several hundred years and the radioactivity level will be less than one tenth of the tolerable amount after 1,000 years or more. This implies that the consideration of intergenerational ethics of geological disposal is meaningless. Ethics developed in western society states that the consent of people in the future is necessary if the disposal has influence on them. Moreover, the ethics depends on generally accepted ideas in western society and preconceptions based on racism and sexism. The irrationality becomes clearer by comparing the dangers of the exhaustion of natural resources and pollution from harmful substances in a recycling society. (author)

  14. The CMS High Level Trigger System

    CERN Document Server

    Afaq, A; Bauer, G; Biery, K; Boyer, V; Branson, J; Brett, A; Cano, E; Carboni, A; Cheung, H; Ciganek, M; Cittolin, S; Dagenhart, W; Erhan, S; Gigi, D; Glege, F; Gómez-Reino, Robert; Gulmini, M; Gutiérrez-Mlot, E; Gutleber, J; Jacobs, C; Kim, J C; Klute, M; Kowalkowski, J; Lipeles, E; Lopez-Perez, Juan Antonio; Maron, G; Meijers, F; Meschi, E; Moser, R; Murray, S; Oh, A; Orsini, L; Paus, C; Petrucci, A; Pieri, M; Pollet, L; Rácz, A; Sakulin, H; Sani, M; Schieferdecker, P; Schwick, C; Sexton-Kennedy, E; Sumorok, K; Suzuki, I; Tsirigkas, D; Varela, J

    2007-01-01

    The CMS Data Acquisition (DAQ) System relies on a purely software driven High Level Trigger (HLT) to reduce the full Level-1 accept rate of 100 kHz to approximately 100 Hz for archiving and later offline analysis. The HLT operates on the full information of events assembled by an event builder collecting detector data from the CMS front-end systems. The HLT software consists of a sequence of reconstruction and filtering modules executed on a farm of O(1000) CPUs built from commodity hardware. This paper presents the architecture of the CMS HLT, which integrates the CMS reconstruction framework in the online environment. The mechanisms to configure, control, and monitor the Filter Farm and the procedures to validate the filtering code within the DAQ environment are described.

  15. High level waste fixation in cermet form

    International Nuclear Information System (INIS)

    Kobisk, E.H.; Aaron, W.S.; Quinby, T.C.; Ramey, D.W.

    1981-01-01

    Commercial and defense high level waste fixation in cermet form is being studied by personnel of the Isotopes Research Materials Laboratory, Solid State Division (ORNL). As a corollary to earlier research and development in forming high density ceramic and cermet rods, disks, and other shapes using separated isotopes, similar chemical and physical processing methods have been applied to synthetic and real waste fixation. Generally, experimental products resulting from this approach have shown physical and chemical characteristics which are deemed suitable for long-term storage, shipping, corrosive environments, high temperature environments, high waste loading, decay heat dissipation, and radiation damage. Although leach tests are not conclusive, what little comparative data are available show cermet to withstand hydrothermal conditions in water and brine solutions. The Soxhlet leach test, using radioactive cesium as a tracer, showed that leaching of cermet was about X100 less than that of 78 to 68 glass. Using essentially uncooled, untreated waste, cermet fixation was found to accommodate up to 75% waste loading and yet, because of its high thermal conductivity, a monolith of 0.6 m diameter and 3.3 m-length would have only a maximum centerline temperature of 29 K above the ambient value

  16. Liquid level measurement in high level nuclear waste slurries

    International Nuclear Information System (INIS)

    Weeks, G.E.; Heckendorn, F.M.; Postles, R.L.

    1990-01-01

    Accurate liquid level measurement has been a difficult problem to solve for the Defense Waste Processing Facility (DWPF). The nuclear waste sludge tends to plug or degrade most commercially available liquid-level measurement sensors. A liquid-level measurement system that meets demanding accuracy requirements for the DWPF has been developed. The system uses a pneumatic 1:1 pressure repeater as a sensor and a computerized error correction system. 2 figs

  17. Levels of trace elements in green turtle eggs collected from Hong Kong: Evidence of risks due to selenium and nickel

    International Nuclear Information System (INIS)

    Lam, James C.W.; Tanabe, Shinsuke; Chan, Simon K.F.; Lam, Michael H.W.; Martin, Michael; Lam, Paul K.S.

    2006-01-01

    Concentrations of 22 trace elements were determined in green turtle (Chelonia mydas) eggs collected from Hong Kong. Concentrations of selenium, lead and nickel in these eggs were generally higher than those reported in other studies. The predicted no effect concentrations (PNEC; ng/g wet weight) of Pb (1000), Se (340 and 6000 for the worst-case and best-case scenarios, respectively) and Ni (17) in the green turtle eggs were estimated. Hazard quotients (HQs) estimate that Se (HQs: 0.2-24.5) and Ni (HQs: 4.0-26.4) may pose some risks to the turtles. Our study also found that concentrations of Ag, Se, Zn, Hg and Pb in the shell of the turtle eggs were significantly correlated with levels in the whole egg contents (yolk + albumen). Once the precise relationships of specific elements are established, egg-shell concentrations may be used as a non-lethal, non-invasive, surrogate for predicting whole egg burden of certain contaminants in marine turtles. - Concentrations of selenium and nickel in green turtle eggs from Hong Kong might pose some risks to the turtles

  18. Levels of trace elements in green turtle eggs collected from Hong Kong: Evidence of risks due to selenium and nickel

    Energy Technology Data Exchange (ETDEWEB)

    Lam, James C.W. [Center for Coastal Pollution and Conservation, Department of Biology and Chemistry, City University of Hong Kong, Kowloon, Hong Kong (China); Tanabe, Shinsuke [Center for Marine Environmental Studies, Ehime University, Tarumi 3-5-7, Matsuyama 790-8556 (Japan); Chan, Simon K.F. [Agriculture, Fisheries and Conservation Department, Hong Kong SAR Government, Hong Kong, (China); Lam, Michael H.W. [Center for Coastal Pollution and Conservation, Department of Biology and Chemistry, City University of Hong Kong, Kowloon, Hong Kong (China); Martin, Michael [Center for Coastal Pollution and Conservation, Department of Biology and Chemistry, City University of Hong Kong, Kowloon, Hong Kong (China); Lam, Paul K.S. [Center for Coastal Pollution and Conservation, Department of Biology and Chemistry, City University of Hong Kong, Kowloon, Hong Kong (China)]. E-mail: bhpksl@cityu.edu.hk

    2006-12-15

    Concentrations of 22 trace elements were determined in green turtle (Chelonia mydas) eggs collected from Hong Kong. Concentrations of selenium, lead and nickel in these eggs were generally higher than those reported in other studies. The predicted no effect concentrations (PNEC; ng/g wet weight) of Pb (1000), Se (340 and 6000 for the worst-case and best-case scenarios, respectively) and Ni (17) in the green turtle eggs were estimated. Hazard quotients (HQs) estimate that Se (HQs: 0.2-24.5) and Ni (HQs: 4.0-26.4) may pose some risks to the turtles. Our study also found that concentrations of Ag, Se, Zn, Hg and Pb in the shell of the turtle eggs were significantly correlated with levels in the whole egg contents (yolk + albumen). Once the precise relationships of specific elements are established, egg-shell concentrations may be used as a non-lethal, non-invasive, surrogate for predicting whole egg burden of certain contaminants in marine turtles. - Concentrations of selenium and nickel in green turtle eggs from Hong Kong might pose some risks to the turtles.

  19. Evaluation of trace element and mineral status and related to levels of amino acid in children with phenylketonuria.

    Science.gov (United States)

    Gok, Fazilet; Ekin, Suat; Dogan, Murat

    2016-07-01

    The aim of the present study was to examine trace elements (Zn, Cu, Mn, Se, Fe, Co, Cr, Ni, Cd, Pb), minerals (Ca, Mg, K), amino acids status in children with phenylketonuria and also whether they were correlated with each other in phenylketonuric patients. It has been found out that the HPA group was significantly lower than the control group with regards to Zn, Se, K, Ca, Mg and Zn/Cr levels (p<0.001, p<0.01, p<0.001, p<0.01, p<0.01 and p<0.001 respectively). In the patients with HPA, significantly strong positive correlations were observed between magnesium and calcium (r=0.791; p=0.001), also, indicates negative significant correlation between the concentrations of magnesium and phenylalanine (r=-0.591; p=0.026). The results of this study showed that, in the HPA group, phenylalanine-Mg relationship found, the presence of disease will in the evaluation of phenylalanine and other amino acids, together with the value of magnesium is required to consider. Copyright © 2016 Elsevier B.V. All rights reserved.

  20. Tracing the spatiotemporally resolved inactivation of optically arranged bacteria by photofunctional microparticles at the single-cell level (Conference Presentation)

    Science.gov (United States)

    Barroso Peña, Alvaro; Grüner, Malte; Forbes, Taylor; Denz, Cornelia; Strassert, Cristian A.

    2016-09-01

    Antimicrobial Photodynamic Inactivation (PDI) represents an attractive alternative in the treatment of infections by antibiotic-resistant pathogenic bacteria. In PDI a photosensitizer (PS) is administered to the site of the biological target in order to generate cytotoxic singlet oxygen which reacts with the biological membrane upon application of harmless visible light. Established methods for testing the photoinduced cytotoxicity of PSs rely on the observation of the whole bacterial ensemble providing only a population-averaged information about the overall produced toxicity. However, for a deeper understanding of the processes that take place in PDI, new methods are required that provide simultaneous regulation of the ROS production, monitoring the subsequent damage induced in the bacteria cells, and full control of the distance between the bacteria and the center of the singlet oxygen production. Herein we present a novel method that enables the quantitative spatio-time-resolved analysis at the single cell level of the photoinduced damage produced by transparent microspheres functionalized with PSs. For this purpose, a methodology was introduced to monitor phototriggered changes with spatiotemporal resolution employing holographic optical tweezers and functional fluorescence microscopy. The defined distance between the photoactive particles and individual bacteria can be fixed under the microscope before the photosensitization process, and the photoinduced damage is monitored by tracing the fluorescence turn-on of a suitable marker. Our methodology constitutes a new tool for the in vitro design and analysis of photosensitizers, as it enables a quantitative response evaluation of living systems towards oxidative stress.

  1. Residential heating contribution to level of air pollutants (PAHs, major, trace, and rare earth elements): a moss bag case study.

    Science.gov (United States)

    Vuković, Gordana; Aničić Urošević, Mira; Pergal, Miodrag; Janković, Milan; Goryainova, Zoya; Tomašević, Milica; Popović, Aleksandar

    2015-12-01

    In areas with moderate to continental climates, emissions from residential heating system lead to the winter air pollution peaks. The EU legislation requires only the monitoring of airborne concentrations of particulate matter, As, Cd, Hg, Ni, and B[a]P. Transition metals and rare earth elements (REEs) have also arisen questions about their detrimental health effects. In that sense, this study examined the level of extensive set of air pollutants: 16 polycyclic aromatic hydrocarbons (PAHs), and 41 major elements, trace elements, and REEs using Sphagnum girgensohnii moss bag technique. During the winter of 2013/2014, the moss bags were exposed across Belgrade (Serbia) to study the influence of residential heating system to the overall air quality. The study was set as an extension to our previous survey during the summer, i.e., non-heating season. Markedly higher concentrations of all PAHs, Sb, Cu, V, Ni, and Zn were observed in the exposed moss in comparison to the initial values. The patterns of the moss REE concentrations normalized to North American Shale Composite and Post-Archean Australian Shales were identical across the study area but enhanced by anthropogenic activities. The results clearly demonstrate the seasonal variations in the moss enrichment of the air pollutants. Moreover, the results point out a need for monitoring of air quality during the whole year, and also of various pollutants, not only those regulated by the EU Directive.

  2. Trace Level Determination of Mesityl Oxide and Diacetone Alcohol in Atazanavir Sulfate Drug Substance by a Gas Chromatography Method.

    Science.gov (United States)

    Raju, K V S N; Pavan Kumar, K S R; Siva Krishna, N; Madhava Reddy, P; Sreenivas, N; Kumar Sharma, Hemant; Himabindu, G; Annapurna, N

    2016-01-01

    A capillary gas chromatography method with a short run time, using a flame ionization detector, has been developed for the quantitative determination of trace level analysis of mesityl oxide and diacetone alcohol in the atazanavir sulfate drug substance. The chromatographic method was achieved on a fused silica capillary column coated with 5% diphenyl and 95% dimethyl polysiloxane stationary phase (Rtx-5, 30 m x 0.53 mm x 5.0 µm). The run time was 20 min employing programmed temperature with a split mode (1:5) and was validated for specificity, sensitivity, precision, linearity, and accuracy. The detection and quantitation limits obtained for mesityl oxide and diacetone alcohol were 5 µg/g and 10 µg/g, respectively, for both of the analytes. The method was found to be linear in the range between 10 µg/g and 150 µg/g with a correlation coefficient greater than 0.999, and the average recoveries obtained in atazanavir sulfate were between 102.0% and 103.7%, respectively, for mesityl oxide and diacetone alcohol. The developed method was found to be robust and rugged. The detailed experimental results are discussed in this research paper.

  3. An improved phase-locked loop method for automatic resonance frequency tracing based on static capacitance broadband compensation for a high-power ultrasonic transducer.

    Science.gov (United States)

    Dong, Hui-juan; Wu, Jian; Zhang, Guang-yu; Wu, Han-fu

    2012-02-01

    The phase-locked loop (PLL) method is widely used for automatic resonance frequency tracing (ARFT) of high-power ultrasonic transducers, which are usually vibrating systems with high mechanical quality factor (Qm). However, a heavily-loaded transducer usually has a low Qm because the load has a large mechanical loss. In this paper, a series of theoretical analyses is carried out to detail why the traditional PLL method could cause serious frequency tracing problems, including loss of lock, antiresonance frequency tracing, and large tracing errors. The authors propose an improved ARFT method based on static capacitance broadband compensation (SCBC), which is able to address these problems. Experiments using a generator based on the novel method were carried out using crude oil as the transducer load. The results obtained have demonstrated the effectiveness of the novel method, compared with the conventional PLL method, in terms of improved tracing accuracy (±9 Hz) and immunity to antiresonance frequency tracing and loss of lock.

  4. Service Oriented Architecture for High Level Applications

    International Nuclear Information System (INIS)

    Chu, P.

    2012-01-01

    Standalone high level applications often suffer from poor performance and reliability due to lengthy initialization, heavy computation and rapid graphical update. Service-oriented architecture (SOA) is trying to separate the initialization and computation from applications and to distribute such work to various service providers. Heavy computation such as beam tracking will be done periodically on a dedicated server and data will be available to client applications at all time. Industrial standard service architecture can help to improve the performance, reliability and maintainability of the service. Robustness will also be improved by reducing the complexity of individual client applications.

  5. The ARES High-level Intermediate Representation

    Energy Technology Data Exchange (ETDEWEB)

    Moss, Nicholas David [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-03-03

    The LLVM intermediate representation (IR) lacks semantic constructs for depicting common high-performance operations such as parallel and concurrent execution, communication and synchronization. Currently, representing such semantics in LLVM requires either extending the intermediate form (a signi cant undertaking) or the use of ad hoc indirect means such as encoding them as intrinsics and/or the use of metadata constructs. In this paper we discuss a work in progress to explore the design and implementation of a new compilation stage and associated high-level intermediate form that is placed between the abstract syntax tree and when it is lowered to LLVM's IR. This highlevel representation is a superset of LLVM IR and supports the direct representation of these common parallel computing constructs along with the infrastructure for supporting analysis and transformation passes on this representation.

  6. Effects of Room Color on Mirror-Tracing by Junior High School Girls.

    Science.gov (United States)

    Bross, Cindy; Jackson, Karen

    1981-01-01

    Girls in Grades 7, 8, and 9 practiced mirror-tracing in a neutral colored room to a criterion before being tested in their preferred or nonpreferred colored rooms. The errors decreased significantly in the preferred room, while the time to complete changed minimally. (Author)

  7. Tracing Clusters to High Red-shift Ray P. Norris & the EMU Team

    Indian Academy of Sciences (India)

    The outputs of the 96 dual-polarization receivers are combined in a beam-former to form up to 36 beams ... Initial observations will produce a global sky model (an accurate descrip- tion of all sources stronger than .... To use radio sources to trace clusters and large-scale structure, and explore the astrophysics of dark matter ...

  8. Exposure to unusually high indoor radon levels

    International Nuclear Information System (INIS)

    Rasheed, F.N.

    1993-01-01

    Unusually high indoor radon concentrations were reported in a small village in western Tyrol, Austria. The authors have measured the seasonal course of indoor radon concentrations in 390 houses of this village. 71% of houses in winter and 33% in summer, showed radon values on the ground floor above the Austrian action level of 400 Bq/cm 3 . This proportion results in an unusually high indoor radon exposure of the population. The radon source was an 8,700-year-old rock slide of granite gneiss, the largest of the alpine crystalline rocks. It has a strong emanating power because its rocks are heavily fractured and show a slightly increased uranium content. Previous reports show increased lung cancer mortality, myeloid leukemia, kidney cancer, melanoma, and prostate cancer resulting from indoor radon exposure. However, many studies fail to provide accurate information on indoor radon concentrations, classifying them merely as low, intermediate, and high, or they record only minor increases in indoor radon concentrations. Mortality data for 1970-91 were used to calculate age and sex standardized mortality rates (SMR) for 51 sites of carcinoma. The total population of Tyrol were controls. A significantly higher risk was recorded for lung cancer. The high SMR for lung cancer in female subjects is especially striking. Because the numbers were low for the other cancer sites, these were combined in one group to calculate the SMR. No significant increase in SMR was found for this group

  9. Technetium Chemistry in High-Level Waste

    International Nuclear Information System (INIS)

    Hess, Nancy J.

    2006-01-01

    Tc contamination is found within the DOE complex at those sites whose mission involved extraction of plutonium from irradiated uranium fuel or isotopic enrichment of uranium. At the Hanford Site, chemical separations and extraction processes generated large amounts of high level and transuranic wastes that are currently stored in underground tanks. The waste from these extraction processes is currently stored in underground High Level Waste (HLW) tanks. However, the chemistry of the HLW in any given tank is greatly complicated by repeated efforts to reduce volume and recover isotopes. These processes ultimately resulted in mixing of waste streams from different processes. As a result, the chemistry and the fate of Tc in HLW tanks are not well understood. This lack of understanding has been made evident in the failed efforts to leach Tc from sludge and to remove Tc from supernatants prior to immobilization. Although recent interest in Tc chemistry has shifted from pretreatment chemistry to waste residuals, both needs are served by a fundamental understanding of Tc chemistry

  10. Processing vessel for high level radioactive wastes

    International Nuclear Information System (INIS)

    Maekawa, Hiromichi

    1998-01-01

    Upon transferring an overpack having canisters containing high level radioactive wastes sealed therein and burying it into an underground processing hole, an outer shell vessel comprising a steel plate to be fit and contained in the processing hole is formed. A bury-back layer made of dug earth and sand which had been discharged upon forming the processing hole is formed on the inner circumferential wall of the outer shell vessel. A buffer layer having a predetermined thickness is formed on the inner side of the bury-back layer, and the overpack is contained in the hollow portion surrounded by the layer. The opened upper portion of the hollow portion is covered with the buffer layer and the bury-back layer. Since the processing vessel having a shielding performance previously formed on the ground, the state of packing can be observed. In addition, since an operator can directly operates upon transportation and burying of the high level radioactive wastes, remote control is no more necessary. (T.M.)

  11. Tracking at High Level Trigger in CMS

    CERN Document Server

    Tosi, Mia

    2016-01-01

    The trigger systems of the LHC detectors play a crucial role in determining the physics capabili- ties of the experiments. A reduction of several orders of magnitude of the event rate is needed to reach values compatible with detector readout, offline storage and analysis capability. The CMS experiment has been designed with a two-level trigger system: the Level-1 Trigger (L1T), implemented on custom-designed electronics, and the High Level Trigger (HLT), a stream- lined version of the CMS offline reconstruction software running on a computer farm. A software trigger system requires a trade-off between the complexity of the algorithms, the sustainable out- put rate, and the selection efficiency. With the computing power available during the 2012 data taking the maximum reconstruction time at HLT was about 200 ms per event, at the nominal L1T rate of 100 kHz. Track reconstruction algorithms are widely used in the HLT, for the reconstruction of the physics objects as well as in the identification of b-jets and ...

  12. CMS High Level Trigger Timing Measurements

    International Nuclear Information System (INIS)

    Richardson, Clint

    2015-01-01

    The two-level trigger system employed by CMS consists of the Level 1 (L1) Trigger, which is implemented using custom-built electronics, and the High Level Trigger (HLT), a farm of commercial CPUs running a streamlined version of the offline CMS reconstruction software. The operational L1 output rate of 100 kHz, together with the number of CPUs in the HLT farm, imposes a fundamental constraint on the amount of time available for the HLT to process events. Exceeding this limit impacts the experiment's ability to collect data efficiently. Hence, there is a critical need to characterize the performance of the HLT farm as well as the algorithms run prior to start up in order to ensure optimal data taking. Additional complications arise from the fact that the HLT farm consists of multiple generations of hardware and there can be subtleties in machine performance. We present our methods of measuring the timing performance of the CMS HLT, including the challenges of making such measurements. Results for the performance of various Intel Xeon architectures from 2009-2014 and different data taking scenarios are also presented. (paper)

  13. Quantification of trace level of fluoride content in uranium oxide produced by deconversion of HEX gas by ion chromatography

    International Nuclear Information System (INIS)

    Unnikrishnan, E.K.; Padmakumar, P.R.; Shanmugavelu, P.; Sudhakar, T.M.; Bhowmik, A.

    2015-01-01

    Fluoride content in nuclear fuel is detrimental due to its corrosion behavior with cladding material. It is essential to monitor and control the fluoride concentration in nuclear material at various processing stages. Deconversion of upgraded HEX gas is carried out to produce uranium oxide. The performance of the deconversion process of HEX gas is evaluated for which trace level of fluoride concentration accompanying uranium oxide is considered as a marker. An analytical method has been developed for testing the uranium oxide produced from deconversion process of HEX gas. The method involves sample pretreatment followed by analysis using ion chromatography. The test method was validated for its performance using in house synthetic uranyl fluoride (UO 2 F 2 ) standard solutions prepared with different level of fluoride content. The results are in agreement with the expected values with the recovery in the range of 80-95%. This method has been successfully implemented for routine analysis of samples at our lab. Since UO 2 F 2 reference material is not available to validate this method, in house UO 2 F 2 standards were prepared from U 3 O 8 prepared from nuclear grade uranyl nitrate solution. UO 2 F 2 standards were prepared by converting U 3 O 8 to UO 2 F 2 by the addition of HF followed by H 2 O 2 at 200°C on a hot plate. The entire yellow colored UO 2 F 2 was dissolved in nano pure water and recrystallised several times to ensure that all free HF is removed. The crystals dried in air oven at 120° for three hours. Samples containing 1000 mg kg -1 fluoride prepared from this UO 2 F 2 , and subsequently from this sample containing 5 mg kg -1 to 35 mg kg -1 fluoride samples were prepared and analysed against fluoride CRM and the fluoride concentration obtained was analysed

  14. On-line sample-pre-treatment schemes for trace-level determinations of metals by coupling flow injection or sequential injection with ICP-MS

    DEFF Research Database (Denmark)

    Wang, Jianhua; Hansen, Elo Harald

    2003-01-01

    a polytetrafluoroethylene (PTFE) knotted reactor (KR), solvent extraction-back extraction and hydride/vapor generation. It also addresses a novel, robust approach, whereby the protocol of SI-LOV-bead injection (BI) on-line separation and pre-concentration of ultra-trace levels of metals by a renewable microcolumn...

  15. Development of ICP-AES based method for the characterization of high level waste

    International Nuclear Information System (INIS)

    Seshagiri, T.K.; Thulsidas, S.K.; Adya, V.C.; Kumar, Mithlesh; Radhakrishnan, K.; Mary, G.; Kulkarni, P.G.; Bhalerao, Bharti; Pant, D.K.

    2011-01-01

    An Inductively Coupled Plasma Atomic Emission Spectrometry (ICP-AES) method was developed for the trace metal characterization of high level waste solutions (HLW) of different origin and the method was validated by analysis of synthetic samples of simulated high level waste solutions (SHLW) from spent fuels of varying composition. In this context, an inter-laboratory comparison exercise (ILCE) was carried out with the simulated HLW of different spent fuel types, viz., research reactor (RR), pressurized heavy water reactor (PHWR) and fast breeder reactor (FBR). An over view of the ICP-AES determination of trace metallic constituents in such SHLW solutions is presented. The overall agreement between the various laboratories was good. (author)

  16. Beam size measurement at high radiation levels

    International Nuclear Information System (INIS)

    Decker, F.J.

    1991-05-01

    At the end of the Stanford Linear Accelerator the high energy electron and positron beams are quite small. Beam sizes below 100 μm (σ) as well as the transverse distribution, especially tails, have to be determined. Fluorescent screens observed by TV cameras provide a quick two-dimensional picture, which can be analyzed by digitization. For running the SLAC Linear Collider (SLC) with low backgrounds at the interaction point, collimators are installed at the end of the linac. This causes a high radiation level so that the nearby cameras die within two weeks and so-called ''radiation hard'' cameras within two months. Therefore an optical system has been built, which guides a 5 mm wide picture with a resolution of about 30 μm over a distance of 12 m to an accessible region. The overall resolution is limited by the screen thickness, optical diffraction and the line resolution of the camera. Vibration, chromatic effects or air fluctuations play a much less important role. The pictures are colored to get fast information about the beam current, size and tails. Beside the emittance, more information about the tail size and betatron phase is obtained by using four screens. This will help to develop tail compensation schemes to decrease the emittance growth in the linac at high currents. 4 refs., 2 figs

  17. CAMAC and high-level-languages

    International Nuclear Information System (INIS)

    Degenhardt, K.H.

    1976-05-01

    A proposal for easy programming of CAMAC systems with high-level-languages (FORTRAN, RTL/2, etc.) and interpreters (BASIC, MUMTI, etc.) using a few subroutines and a LAM driver is presented. The subroutines and the LAM driver are implemented for PDP11/RSX-11M and for the CAMAC controllers DEC CA11A (branch controller), BORER type 1533A (single crate controller) and DEC CA11F (single crate controller). Mixed parallel/serial CAMAC systems employing KINETIC SYSTEMS serial driver mod. 3992 and serial crate controllers mod. 3950 are implemented for all mentioned parallel controllers, too. DMA transfers from or to CAMAC modules using non-processor-request controllers (BORER type 1542, DEC CA11FN) are available. (orig.) [de

  18. National high-level waste systems analysis

    International Nuclear Information System (INIS)

    Kristofferson, K.; O'Holleran, T.P.

    1996-01-01

    Previously, no mechanism existed that provided a systematic, interrelated view or national perspective of all high-level waste treatment and storage systems that the US Department of Energy manages. The impacts of budgetary constraints and repository availability on storage and treatment must be assessed against existing and pending negotiated milestones for their impact on the overall HLW system. This assessment can give DOE a complex-wide view of the availability of waste treatment and help project the time required to prepare HLW for disposal. Facilities, throughputs, schedules, and milestones were modeled to ascertain the treatment and storage systems resource requirements at the Hanford Site, Savannah River Site, Idaho National Engineering Laboratory, and West Valley Demonstration Project. The impacts of various treatment system availabilities on schedule and throughput were compared to repository readiness to determine the prudent application of resources. To assess the various impacts, the model was exercised against a number of plausible scenarios as discussed in this paper

  19. International high-level radioactive waste repositories

    International Nuclear Information System (INIS)

    Lin, W.

    1996-01-01

    Although nuclear technologies benefit everyone, the associated nuclear wastes are a widespread and rapidly growing problem. Nuclear power plants are in operation in 25 countries, and are under construction in others. Developing countries are hungry for electricity to promote economic growth; industrialized countries are eager to export nuclear technologies and equipment. These two ingredients, combined with the rapid shrinkage of worldwide fossil fuel reserves, will increase the utilization of nuclear power. All countries utilizing nuclear power produce at least a few tens of tons of spent fuel per year. That spent fuel (and reprocessing products, if any) constitutes high-level nuclear waste. Toxicity, long half-life, and immunity to chemical degradation make such waste an almost permanent threat to human beings. This report discusses the advantages of utilizing repositories for disposal of nuclear wastes

  20. High-level waste processing and disposal

    International Nuclear Information System (INIS)

    Crandall, J.L.; Krause, H.; Sombret, C.; Uematsu, K.

    1984-11-01

    Without reprocessing, spent LWR fuel itself is generally considered an acceptable waste form. With reprocessing, borosilicate glass canisters, have now gained general acceptance for waste immobilization. The current first choice for disposal is emplacement in an engineered structure in a mined cavern at a depth of 500-1000 meters. A variety of rock types are being investigated including basalt, clay, granite, salt, shale, and volcanic tuff. This paper gives specific coverage to the national high level waste disposal plans for France, the Federal Republic of Germany, Japan and the United States. The French nuclear program assumes prompt reprocessing of its spent fuels, and France has already constructed the AVM. Two larger borosilicate glass plants are planned for a new French reprocessing plant at La Hague. France plans to hold the glass canisters in near-surface storage for a forty to sixty year cooling period and then to place them into a mined repository. The FRG and Japan also plan reprocessing for their LWR fuels. Both are currently having some fuel reprocessed by France, but both are also planning reprocessing plants which will include waste vitrification facilities. West Germany is now constructing the PAMELA Plant at Mol, Belgium to vitrify high level reprocessing wastes at the shutdown Eurochemic Plant. Japan is now operating a vitrification mockup test facility and plans a pilot plant facility at the Tokai reprocessing plant by 1990. Both countries have active geologic repository programs. The United State program assumes little LWR fuel reprocessing and is thus primarily aimed at direct disposal of spent fuel into mined repositories. However, the US have two borosilicate glass plants under construction to vitrify existing reprocessing wastes

  1. Cork-based activated carbons as supported adsorbent materials for trace level analysis of ibuprofen and clofibric acid in environmental and biological matrices.

    Science.gov (United States)

    Neng, N R; Mestre, A S; Carvalho, A P; Nogueira, J M F

    2011-09-16

    In this contribution, powdered activated carbons (ACs) from cork waste were supported for bar adsorptive micro-extraction (BAμE), as novel adsorbent phases for the analysis of polar compounds. By combining this approach with liquid desorption followed by high performance liquid chromatography with diode array detection (BAμE(AC)-LD/HPLC-DAD), good analytical performance was achieved using clofibric acid (CLOF) and ibuprofen (IBU) model compounds in environmental and biological matrices. Assays performed on 30 mL water samples spiked at the 25.0 μg L(-1) level yielded recoveries around 80% for CLOF and 95% for IBU, under optimized experimental conditions. The ACs textural and surface chemistry properties were correlated with the results obtained. The analytical performance showed good precision (0.9922) from 1.0 to 600.0 μg L(-1). By using the standard addition methodology, the application of the present approach to environmental water and urine matrices allowed remarkable performance at the trace level. The proposed methodology proved to be a viable alternative for acidic pharmaceuticals analysis, showing to be easy to implement, reliable, sensitive and requiring low sample volume to monitor these priority compounds in environmental and biological matrices. Copyright © 2011 Elsevier B.V. All rights reserved.

  2. Environmental Exposure of Children to Toxic Trace Elements (Hg, Cr, As) in an Urban Area of Yucatan, Mexico: Water, Blood, and Urine Levels.

    Science.gov (United States)

    Arcega-Cabrera, F; Fargher, L; Quesadas-Rojas, M; Moo-Puc, R; Oceguera-Vargas, I; Noreña-Barroso, E; Yáñez-Estrada, L; Alvarado, J; González, L; Pérez-Herrera, N; Pérez-Medina, S

    2018-05-01

    Merida is the largest urban center in the Mexican State of Yucatan. Here domestic sewage is deposited in poorly built septic tanks and is not adequately treated. Because of contamination from such waste, water from the top 20 m of the aquifer is unsuitable for human consumption. Given this situation and because children are highly vulnerable to environmental pollution, including exposure to toxic trace elements, this study focused on evaluating the exposure of children to arsenic (As), chromium (Cr), and mercury (Hg) in water. It also evaluated the relationship between the levels of these elements in water and their concentrations in urine and blood. Among the 33 children monitored in the study, arsenic surpassed WHO limits for blood in 37% of the cases, which could result from the ingestion of poultry contaminated with organoarsenic compounds. In the case of WHO limits for Mercury, 65% of the water samples analyzed, 28% of urine samples, and 12% of blood samples exceeded them. Mercury exposure was correlated with biological sex, some lifestyle factors, and the zone in Merida in which children live. These data suggest that the levels of some toxic metals in children may be affected by water source, socioeconomic factors, and individual behavior.

  3. Evaluation of distribution patterns and decision of distribution coefficients of trace elements in high-purity aluminium by INAA

    International Nuclear Information System (INIS)

    Hayakawa, Yasuhiro; Suzuki, Shogo; Hirai, Shoji

    1986-01-01

    Recently, a high-purity aluminium has been used in semi-coductor device, so on. It was required that trace impurities should be reduced and that its content should be quantitatively evaluated. In this study, distribution patterns of many trace impurities in 99.999 % aluminium ingots, which was purified using a normal freezing method, were evaluated by an INAA. The effective distribution coefficient k for each detected elements was calculated using a theoretical distribution equation in the normal freezing method. As a result, the elements of k 1 was Hf. Especially, La, Sm, U and Th could be effectively purified, but Sc and Hf could be scarcely purified. Further more, it was found that the slower freezing gave the effective distribution coefficient close to the equilibrium distribution coefficient, and that the effective distribution coefficient became smaller with the larger atomic radius. (author)

  4. Assessment of Trace Element Levels in Muscle Tissues of Fish Species Collected from a River, Stream, Lake, and Sea in Sakarya, Turkey

    Directory of Open Access Journals (Sweden)

    Tülay Küpeli

    2014-01-01

    Full Text Available Levels of some trace and essential elements, including Al, B, Ba, Cr, Cu, Fe, Mn, Ni, Sr, and Zn, were determined in 17 different fish species from Sakarya River, Çark Stream, Sapanca Lake, and Western Black Sea using ICP-OES after microwave (MW digestion procedure. During preparation of samples for analysis, wet and MW digestion methods were also compared. Accuracy of the digestion methods was checked by the analysis of DORM-3 reference material (Fish Protein Certified Reference Material for Trace Metals. Concentrations of trace elements were found as Al: 6.5–48.5, B: 0.06–3.30, Ba: 0.09–2.92, Cr: 0.02–1.64, Cu: 0.13–2.28, Fe: 7.28–39.9, Mn: 0.08–11.4, Ni: 0.01–26.1, Sr: 0.17–13.5, and Zn: 11.5–52.9 µg g−1. The obtained results were compared with other studies published in the literature. Trace element levels in various fish species collected from waters in Sakarya region were found to be below limit values provided by Turkish Food Codex (TFC, Food and Agriculture Organization (FAO, and World Health Organization (WHO.

  5. High-level radioactive waste management

    International Nuclear Information System (INIS)

    Schneider, K.J.; Liikala, R.C.

    1974-01-01

    High-level radioactive waste in the U.S. will be converted to an encapsulated solid and shipped to a Federal repository for retrievable storage for extended periods. Meanwhile the development of concepts for ultimate disposal of the waste which the Federal Government would manage is being actively pursued. A number of promising concepts have been proposed, for which there is high confidence that one or more will be suitable for long-term, ultimate disposal. Initial evaluations of technical (or theoretical) feasibility for the various waste disposal concepts show that in the broad category, (i.e., geologic, seabed, ice sheet, extraterrestrial, and transmutation) all meet the criteria for judging feasibility, though a few alternatives within these categories do not. Preliminary cost estimates show that, although many millions of dollars may be required, the cost for even the most exotic concepts is small relative to the total cost of electric power generation. For example, the cost estimates for terrestrial disposal concepts are less than 1 percent of the total generating costs. The cost for actinide transmutation is estimated at around 1 percent of generation costs, while actinide element disposal in space is less than 5 percent of generating costs. Thus neither technical feasibility nor cost seems to be a no-go factor in selecting a waste management system. The seabed, ice sheet, and space disposal concepts face international policy constraints. The information being developed currently in safety, environmental concern, and public response will be important factors in determining which concepts appear most promising for further development

  6. Fast GC-analysis of selected organic compounds at trace levels with the novel RAPID-MS/MS-technology

    International Nuclear Information System (INIS)

    Poell, S.

    2002-03-01

    The main topic of the present thesis was the development of rapid analytical procedures for the environmental analysis of a steel producing company, to speed up the sample throughput for the daily routine work. Additionally, high precision of analysis results was requested. This brought a certain effort concerning the validation of the results which was supported by the analysis of certified reference materials. Special interest was laid on the optimization of the trace analysis of dioxins and furans (PCDD/DF). An expansion of the established methods with powerful techniques like single ion storage and tandem-mass spectrometry resulted in an obvious improvement of the limits of quantitation and the reliability of analysis. Further advances could be achieved with the simplification of the clean-up procedure by the application of a new sampling technique which reduced the demand on sample preparation time as well. Analysis were also carried out with brominated Dioxins and Furans (PBrDD/DF). The next item focused on the analysis of polycyclic aromatic hydrocarbons (PAH) with the implementation of five new representatives with a highly carcinogenic potential. In this case, the coupling of three detectors resulted in a robust and precise HPLC-method with a highly qualitative and quantitative analytical reliability. Furthermore, the aim was to promote the routine analysis of alkylated aromatics (BTEX) and halogenated volatile organic (VOC) compounds. By the use of gas chromatography coupled with mass spectrometric detection a common analytical technique for both classes of substances could be found with an enhancement of sensitivity due to application of the single ion storage technique. The existing method for the determination of polychlorinated biphenyls (PCB) was improved by replacing the electron capture detector with mass spectrometry. Due to an optimization of the single ion storage and tandem mass spectrometry parameters the requested demands on low detection

  7. Vitrification of high-level liquid wastes

    International Nuclear Information System (INIS)

    Varani, J.L.; Petraitis, E.J.; Vazquez, Antonio.

    1987-01-01

    High-level radioactive liquid wastes produced in the fuel elements reprocessing require, for their disposal, a preliminary treatment by which, through a series of engineering barriers, the dispersion into the biosphere is delayed by 10 000 years. Four groups of compounds are distinguished among a great variety of final products and methods of elaboration. From these, the borosilicate glasses were chosen. Vitrification experiences were made at a laboratory scale with simulated radioactive wastes, employing different compositions of borosilicate glass. The installations are described. A series of tests were carried out on four basic formulae using always the same methodology, consisting of a dry mixture of the vitreous matrix's products and a dry simulated mixture. Several quality tests of the glasses were made 1: Behaviour in leaching following the DIN 12 111 standard; 2: Mechanical resistance; parameters related with the facility of the different glasses for increasing their surface were studied; 3: Degree of devitrification: it is shown that devitrification turns the glasses containing radioactive wastes easily leachable. From all the glasses tested, the composition SiO 2 , Al 2 O 3 , B 2 O 3 , Na 2 O, CaO shows the best retention characteristics. (M.E.L.) [es

  8. Ocean disposal of high level radioactive waste

    International Nuclear Information System (INIS)

    1983-01-01

    This study confirms, subject to limitations of current knowledge, the engineering feasibility of free fall penetrators for High Level Radioactive Waste disposal in deep ocean seabed sediments. Restricted sediment property information is presently the principal bar to an unqualified statement of feasibility. A 10m minimum embedment and a 500 year engineered barrier waste containment life are identified as appropriate basic penetrator design criteria at this stage. A range of designs are considered in which the length, weight and cross section of the penetrator are varied. Penetrators from 3m to 20m long and 2t to 100t in weight constructed of material types and thicknesses to give a 500 year containment life are evaluated. The report concludes that the greatest degree of confidence is associated with performance predictions for 75 to 200 mm thick soft iron and welded joints. A range of lengths and capacities from a 3m long single waste canister penetrator to a 20m long 12 canister design are identified as meriting further study. Estimated embedment depths for this range of penetrator designs lie between 12m and 90m. Alternative manufacture, transport and launch operations are assessed and recommendations are made. (author)

  9. Vitrification of high level wastes in France

    International Nuclear Information System (INIS)

    Sombret, C.

    1984-02-01

    A brief historical background of the research and development work conducted in France over 25 years is first presented. Then, the papers deals with the vitrification at (1) the UP1 reprocessing plant (Marcoule) and (2) the UP2 and UP3 reprocessing plants (La Hague). 1) The properties of glass required for high-level radioactive waste vitrification are recalled. The vitrification process and facility of Marcoule are presented. (2) The average characteristics (chemical composition, activity) of LWR fission product solution are given. The glass formulations developed to solidify LWR waste solution must meet the same requirements as those used in the UP1 facility at Marcoule. Three important aspects must be considered with respect to the glass fabrication process: corrosiveness of the molten glass with regard to metals, viscosity of the molten glass, and, volatization during glass fabrication. The glass properties required in view of interim storage and long-term disposal are then largely developed. Two identical vitrification facilities are planned for the site: T7, to process the UP2 throughput, and T7 for the UP3 plant. A prototype unit was built and operated at Marcoule

  10. High-level nuclear waste disposal

    International Nuclear Information System (INIS)

    Burkholder, H.C.

    1985-01-01

    The meeting was timely because many countries had begun their site selection processes and their engineering designs were becoming well-defined. The technology of nuclear waste disposal was maturing, and the institutional issues arising from the implementation of that technology were being confronted. Accordingly, the program was structured to consider both the technical and institutional aspects of the subject. The meeting started with a review of the status of the disposal programs in eight countries and three international nuclear waste management organizations. These invited presentations allowed listeners to understand the similarities and differences among the various national approaches to solving this very international problem. Then seven invited presentations describing nuclear waste disposal from different perspectives were made. These included: legal and judicial, electric utility, state governor, ethical, and technical perspectives. These invited presentations uncovered several issues that may need to be resolved before high-level nuclear wastes can be emplaced in a geologic repository in the United States. Finally, there were sixty-six contributed technical presentations organized in ten sessions around six general topics: site characterization and selection, repository design and in-situ testing, package design and testing, disposal system performance, disposal and storage system cost, and disposal in the overall waste management system context. These contributed presentations provided listeners with the results of recent applied RandD in each of the subject areas

  11. Decontamination of high-level waste canisters

    International Nuclear Information System (INIS)

    Nesbitt, J.F.; Slate, S.C.; Fetrow, L.K.

    1980-12-01

    This report presents evaluations of several methods for the in-process decontamination of metallic canisters containing any one of a number of solidified high-level waste (HLW) forms. The use of steam-water, steam, abrasive blasting, electropolishing, liquid honing, vibratory finishing and soaking have been tested or evaluated as potential techniques to decontaminate the outer surfaces of HLW canisters. Either these techniques have been tested or available literature has been examined to assess their applicability to the decontamination of HLW canisters. Electropolishing has been found to be the most thorough method to remove radionuclides and other foreign material that may be deposited on or in the outer surface of a canister during any of the HLW processes. Steam or steam-water spraying techniques may be adequate for some applications but fail to remove all contaminated forms that could be present in some of the HLW processes. Liquid honing and abrasive blasting remove contamination and foreign material very quickly and effectively from small areas and components although these blasting techniques tend to disperse the material removed from the cleaned surfaces. Vibratory finishing is very capable of removing the bulk of contamination and foreign matter from a variety of materials. However, special vibratory finishing equipment would have to be designed and adapted for a remote process. Soaking techniques take long periods of time and may not remove all of the smearable contamination. If soaking involves pickling baths that use corrosive agents, these agents may cause erosion of grain boundaries that results in rough surfaces

  12. Trace glucose and lipid metabolism in high androgen and high-fat diet induced polycystic ovary syndrome rats

    Directory of Open Access Journals (Sweden)

    Zhai Hua-Ling

    2012-01-01

    Full Text Available Abstract Background There is a high prevalence of diabetes mellitus (DM and dyslipidemia in women with polycystic ovary syndrome (PCOS. The purpose of this study was to investigate the role of different metabolic pathways in the development of diabetes mellitus in high-androgen female mice fed with a high-fat diet. Methods Female Sprague-Dawley rats were divided into 3 groups: the control group(C, n = 10; the andronate-treated group (Andronate, n = 10 (treated with andronate, 1 mg/100 g body weight/day for 8 weeks; and the andronate-treated and high-fat diet group (Andronate+HFD, n = 10. The rate of glucose appearance (Ra of glucose, gluconeogenesis (GNG, and the rate of glycerol appearance (Ra of glycerol were assessed with a stable isotope tracer. The serum sex hormone levels, insulin levels, glucose concentration, and the lipid profile were also measured. Results Compared with control group, both andronate-treated groups exhibited obesity with higher insulin concentrations (P P Conclusions Andronate with HFD rat model showed ovarian and metabolic features of PCOS, significant increase in glucose Ra, GNG, and lipid profiles, as well as normal blood glucose levels. Therefore, aberrant IR, increased glucose Ra, GNG, and lipid metabolism may represent the early-stage of glucose and lipid kinetics disorder, thereby might be used as potential early-stage treatment targets for PCOS.

  13. Determination of Mineral, Trace Element, and Pesticide Levels in Honey Samples Originating from Different Regions of Malaysia Compared to Manuka Honey

    Science.gov (United States)

    Moniruzzaman, Mohammed; Chowdhury, Muhammed Alamgir Zaman; Rahman, Mohammad Abdur; Sulaiman, Siti Amrah; Gan, Siew Hua

    2014-01-01

    The present study was undertaken to determine the content of six minerals, five trace elements, and ten pesticide residues in honeys originating from different regions of Malaysia. Calcium (Ca), magnesium (Mg), iron (Fe), and zinc (Zn) were analyzed by flame atomic absorption spectrometry (FAAS), while sodium (Na) and potassium (K) were analyzed by flame emission spectrometry (FAES). Trace elements such as arsenic (As), lead (Pb), cadmium (Cd), copper (Cu), and cobalt (Co) were analyzed by graphite furnace atomic absorption spectrometry (GFAAS) following the microwave digestion of honey. High mineral contents were observed in the investigated honeys with K, Na, Ca, and Fe being the most abundant elements (mean concentrations of 1349.34, 236.80, 183.67, and 162.31 mg/kg, resp.). The concentrations of the trace elements were within the recommended limits, indicating that the honeys were of good quality. Principal component analysis reveals good discrimination between the different honey samples. The pesticide analysis for the presence of organophosphorus and carbamates was performed by high performance liquid chromatography (HPLC). No pesticide residues were detected in any of the investigated honey samples, indicating that the honeys were pure. Our study reveals that Malaysian honeys are rich sources of minerals with trace elements present within permissible limits and that they are free from pesticide contamination. PMID:24982869

  14. Determination of Mineral, Trace Element, and Pesticide Levels in Honey Samples Originating from Different Regions of Malaysia Compared to Manuka Honey

    Directory of Open Access Journals (Sweden)

    Mohammed Moniruzzaman

    2014-01-01

    Full Text Available The present study was undertaken to determine the content of six minerals, five trace elements, and ten pesticide residues in honeys originating from different regions of Malaysia. Calcium (Ca, magnesium (Mg, iron (Fe, and zinc (Zn were analyzed by flame atomic absorption spectrometry (FAAS, while sodium (Na and potassium (K were analyzed by flame emission spectrometry (FAES. Trace elements such as arsenic (As, lead (Pb, cadmium (Cd, copper (Cu, and cobalt (Co were analyzed by graphite furnace atomic absorption spectrometry (GFAAS following the microwave digestion of honey. High mineral contents were observed in the investigated honeys with K, Na, Ca, and Fe being the most abundant elements (mean concentrations of 1349.34, 236.80, 183.67, and 162.31 mg/kg, resp.. The concentrations of the trace elements were within the recommended limits, indicating that the honeys were of good quality. Principal component analysis reveals good discrimination between the different honey samples. The pesticide analysis for the presence of organophosphorus and carbamates was performed by high performance liquid chromatography (HPLC. No pesticide residues were detected in any of the investigated honey samples, indicating that the honeys were pure. Our study reveals that Malaysian honeys are rich sources of minerals with trace elements present within permissible limits and that they are free from pesticide contamination.

  15. Determination of mineral, trace element, and pesticide levels in honey samples originating from different regions of Malaysia compared to manuka honey.

    Science.gov (United States)

    Moniruzzaman, Mohammed; Chowdhury, Muhammed Alamgir Zaman; Rahman, Mohammad Abdur; Sulaiman, Siti Amrah; Gan, Siew Hua

    2014-01-01

    The present study was undertaken to determine the content of six minerals, five trace elements, and ten pesticide residues in honeys originating from different regions of Malaysia. Calcium (Ca), magnesium (Mg), iron (Fe), and zinc (Zn) were analyzed by flame atomic absorption spectrometry (FAAS), while sodium (Na) and potassium (K) were analyzed by flame emission spectrometry (FAES). Trace elements such as arsenic (As), lead (Pb), cadmium (Cd), copper (Cu), and cobalt (Co) were analyzed by graphite furnace atomic absorption spectrometry (GFAAS) following the microwave digestion of honey. High mineral contents were observed in the investigated honeys with K, Na, Ca, and Fe being the most abundant elements (mean concentrations of 1349.34, 236.80, 183.67, and 162.31 mg/kg, resp.). The concentrations of the trace elements were within the recommended limits, indicating that the honeys were of good quality. Principal component analysis reveals good discrimination between the different honey samples. The pesticide analysis for the presence of organophosphorus and carbamates was performed by high performance liquid chromatography (HPLC). No pesticide residues were detected in any of the investigated honey samples, indicating that the honeys were pure. Our study reveals that Malaysian honeys are rich sources of minerals with trace elements present within permissible limits and that they are free from pesticide contamination.

  16. DEFENSE HIGH LEVEL WASTE GLASS DEGRADATION

    International Nuclear Information System (INIS)

    Ebert, W.

    2001-01-01

    The purpose of this Analysis/Model Report (AMR) is to document the analyses that were done to develop models for radionuclide release from high-level waste (HLW) glass dissolution that can be integrated into performance assessment (PA) calculations conducted to support site recommendation and license application for the Yucca Mountain site. This report was developed in accordance with the ''Technical Work Plan for Waste Form Degradation Process Model Report for SR'' (CRWMS M andO 2000a). It specifically addresses the item, ''Defense High Level Waste Glass Degradation'', of the product technical work plan. The AP-3.15Q Attachment 1 screening criteria determines the importance for its intended use of the HLW glass model derived herein to be in the category ''Other Factors for the Postclosure Safety Case-Waste Form Performance'', and thus indicates that this factor does not contribute significantly to the postclosure safety strategy. Because the release of radionuclides from the glass will depend on the prior dissolution of the glass, the dissolution rate of the glass imposes an upper bound on the radionuclide release rate. The approach taken to provide a bound for the radionuclide release is to develop models that can be used to calculate the dissolution rate of waste glass when contacted by water in the disposal site. The release rate of a particular radionuclide can then be calculated by multiplying the glass dissolution rate by the mass fraction of that radionuclide in the glass and by the surface area of glass contacted by water. The scope includes consideration of the three modes by which water may contact waste glass in the disposal system: contact by humid air, dripping water, and immersion. The models for glass dissolution under these contact modes are all based on the rate expression for aqueous dissolution of borosilicate glasses. The mechanism and rate expression for aqueous dissolution are adequately understood; the analyses in this AMR were conducted to

  17. Evaluation of a Candidate Trace Contaminant Control Subsystem Architecture: The High Velocity, Low Aspect Ratio (HVLA) Adsorption Process

    Science.gov (United States)

    Kayatin, Matthew J.; Perry, Jay L.

    2017-01-01

    Traditional gas-phase trace contaminant control adsorption process flow is constrained as required to maintain high contaminant single-pass adsorption efficiency. Specifically, the bed superficial velocity is controlled to limit the adsorption mass-transfer zone length relative to the physical adsorption bed; this is aided by traditional high-aspect ratio bed design. Through operation in this manner, most contaminants, including those with relatively high potential energy are readily adsorbed. A consequence of this operational approach, however, is a limited available operational flow margin. By considering a paradigm shift in adsorption architecture design and operations, in which flows of high superficial velocity are treated by low-aspect ratio sorbent beds, the range of well-adsorbed contaminants becomes limited, but the process flow is increased such that contaminant leaks or emerging contaminants of interest may be effectively controlled. To this end, the high velocity, low aspect ratio (HVLA) adsorption process architecture was demonstrated against a trace contaminant load representative of the International Space Station atmosphere. Two HVLA concept packaging designs (linear flow and radial flow) were tested. The performance of each design was evaluated and compared against computer simulation. Utilizing the HVLA process, long and sustained control of heavy organic contaminants was demonstrated.

  18. Effect of different levels of alpha tocopherol on performance traits, serum antioxidant enzymes, and trace elements in Japanese quail ( Coturnix coturnix japonica under low ambient temperature

    Directory of Open Access Journals (Sweden)

    Assar Ali Shah

    Full Text Available ABSTRACT This study was designed to find the effect of vitamin E supplementation on growth, serum antioxidant enzymes, and some trace elements in Japanese quail (Coturnix coturnix japonica under low ambient temperature. A total of 180 day-old Japanese quails were randomly divided into four groups and provided with 0 (group A, 50 (group B, 100 (group C, and 150 IU/kg (group D vitamin E (dl-α-tocopherol acetate under an average temperature of 9±0.5 °C for an experimental period of 42 days. The result showed that feed intake per day, body weight, weight gain per day, and feed conversion ratio did not differ significantly between the groups. Serum concentrations of superoxide and glutathione peroxidase were significantly high in birds supplemented with 150 mg/kg of vitamin E. The concentration of aspartate aminotransferase was not significantly affected between the control and treated groups; however, alanine transaminase concentration significantly reduced in group D. Zinc concentration in the blood increased significantly in group D, with no significant effect on copper and manganese between the control and treated groups. Vitamin E at the level of 150 IU/kg of feed improves the blood antioxidant status and zinc concentration, with no effect on the performance traits of quail reared under low ambient temperature.

  19. Trace-level mercury ion (Hg2+) analysis in aqueous sample based on solid-phase extraction followed by microfluidic immunoassay.

    Science.gov (United States)

    Date, Yasumoto; Aota, Arata; Terakado, Shingo; Sasaki, Kazuhiro; Matsumoto, Norio; Watanabe, Yoshitomo; Matsue, Tomokazu; Ohmura, Naoya

    2013-01-02

    Mercury is considered the most important heavy-metal pollutant, because of the likelihood of bioaccumulation and toxicity. Monitoring widespread ionic mercury (Hg(2+)) contamination requires high-throughput and cost-effective methods to screen large numbers of environmental samples. In this study, we developed a simple and sensitive analysis for Hg(2+) in environmental aqueous samples by combining a microfluidic immunoassay and solid-phase extraction (SPE). Using a microfluidic platform, an ultrasensitive Hg(2+) immunoassay, which yields results within only 10 min and with a lower detection limit (LOD) of 0.13 μg/L, was developed. To allow application of the developed immunoassay to actual environmental aqueous samples, we developed an ion-exchange resin (IER)-based SPE for selective Hg(2+) extraction from an ion mixture. When using optimized SPE conditions, followed by the microfluidic immunoassay, the LOD of the assay was 0.83 μg/L, which satisfied the guideline values for drinking water suggested by the United States Environmental Protection Agency (USEPA) (2 μg/L; total mercury), and the World Health Organisation (WHO) (6 μg/L; inorganic mercury). Actual water samples, including tap water, mineral water, and river water, which had been spiked with trace levels of Hg(2+), were well-analyzed by SPE, followed by microfluidic Hg(2+) immunoassay, and the results agreed with those obtained from reduction vaporizing-atomic adsorption spectroscopy.

  20. Trace level detection of compounds related to the chemical weapons convention by 1H-detected 13C NMR spectroscopy executed with a sensitivity-enhanced, cryogenic probehead.

    Science.gov (United States)

    Cullinan, David B; Hondrogiannis, George; Henderson, Terry J

    2008-04-15

    Two-dimensional 1H-13C HSQC (heteronuclear single quantum correlation) and fast-HMQC (heteronuclear multiple quantum correlation) pulse sequences were implemented using a sensitivity-enhanced, cryogenic probehead for detecting compounds relevant to the Chemical Weapons Convention present in complex mixtures. The resulting methods demonstrated exceptional sensitivity for detecting the analytes at trace level concentrations. 1H-13C correlations of target analytes at chemical shift information could be derived quickly and simultaneously from the resulting spectra. The fast-HMQC pulse sequences generated magnitude mode spectra suitable for detailed analysis in approximately 4.5 h and can be used in experiments to efficiently screen a large number of samples. The HSQC pulse sequences, on the other hand, required roughly twice the data acquisition time to produce suitable spectra. These spectra, however, were phase-sensitive, contained considerably more resolution in both dimensions, and proved to be superior for detecting analyte 1H-13C correlations. Furthermore, a HSQC spectrum collected with a multiplicity-edited pulse sequence provided additional structural information valuable for identifying target analytes. The HSQC pulse sequences are ideal for collecting high-quality data sets with overnight acquisitions and logically follow the use of fast-HMQC pulse sequences to rapidly screen samples for potential target analytes. Use of the pulse sequences considerably improves the performance of NMR spectroscopy as a complimentary technique for the screening, identification, and validation of chemical warfare agents and other small-molecule analytes present in complex mixtures and environmental samples.

  1. Growth Performance, Mineral Digestibility, and Blood Characteristics of Ostriches Receiving Drinking Water Supplemented with Varying Levels of Chelated Trace Mineral Complex.

    Science.gov (United States)

    Seyfori, Hossein; Ghasemi, Hossein Ali; Hajkhodadadi, Iman; Nazaran, Mohammad Hassan; Hafizi, Maryam

    2018-05-01

    The effects of water supplementation of chelated trace minerals (CTM, which is named Bonzaplex designed with chelate compounds technology) on growth performance, apparent total tract digestibility (ATTD) of minerals, and some blood metabolites, TM, and antioxidant enzyme values in African ostriches were investigated from 8 to 12 months of age. A total of 20 8-month-old ostriches (five birds in five replicate pens) was randomly allocated into one of the following four treatments: (1) control (basal diet + tap water), (2) low CTM (basal diet +100 mg/bird/day CTM powder in tap water), (3) medium CTM (basal diet +1 g/bird/day CTM powder in tap water), and (4) high CTM (basal diet +2 g/bird/day CTM powder in tap water). Compared with control, medium CTM improved (P water can be recommended for improving growth performance, mineral absorption, and antioxidant status of ostriches fed diets containing the recommended levels of inorganic TM.

  2. Nova performance at ultra high fluence levels

    International Nuclear Information System (INIS)

    Hunt, J.T.

    1986-01-01

    Nova is a ten beam high power Nd:glass laser used for interial confinement fusion research. It was operated in the high power high energy regime following the completion of construction in December 1984. During this period several interesting nonlinear optical phenomena were observed. These phenomena are discussed in the text. 11 refs., 5 figs

  3. TraceContract: A Scala DSL for Trace Analysis

    Science.gov (United States)

    Barringer, Howard; Havelund, Klaus

    2011-01-01

    In this paper we describe TRACECONTRACT, an API for trace analysis, implemented in the SCALA programming language. We argue that for certain forms of trace analysis the best weapon is a high level programming language augmented with constructs for temporal reasoning. A trace is a sequence of events, which may for example be generated by a running program, instrumented appropriately to generate events. The API supports writing properties in a notation that combines an advanced form of data parameterized state machines with temporal logic. The implementation utilizes SCALA's support for defining internal Domain Specific Languages (DSLs). Furthermore SCALA's combination of object oriented and functional programming features, including partial functions and pattern matching, makes it an ideal host language for such an API.

  4. Graphite electrodes modified by 8-hydroxyquinolines and its application for the determination of copper in trace levels

    Directory of Open Access Journals (Sweden)

    Sousa Eliane R. de

    2006-01-01

    Full Text Available Surface modification by 8-hydroxyquinoline-5-sulfonic acid (8-HQS or 8-hydroxyquinoline (8-HQ on a graphite electrode through irreversible adsorption is reported in this paper. Cyclic voltammetry was used to characterize the surface behavior. The modified surface exhibited an affinity to chelating Cu(II in the solution, forming a Cu(II complex, which was employed for Cu(II trace analysis. Of the metals Zn, Ni, Pb, Co, and Cd, none presented interference until excess concentration of 10 times. Significant interference could be observed from Co(II, Cd(II and Fe(II for an excess concentration of 100 times on the analyte. A differential pulse voltammetry, combined with a preconcentrating-stripping process and a standard addition method was used for the analysis. A detection limit for trace copper determination in water, such as 5.110-9 mol L-1, was obtained.

  5. High bicarbonate levels in narcoleptic children.

    Science.gov (United States)

    Franco, Patricia; Junqua, Aurelie; Guignard-Perret, Anne; Raoux, Aude; Perier, Magali; Raverot, Veronique; Claustrat, Bruno; Gustin, Marie-Paule; Inocente, Clara Odilia; Lin, Jian-Sheng

    2016-04-01

    The objective of this study was to evaluate the levels of plasma bicarbonate levels in narcoleptic children. Clinical, electrophysiological data and bicarbonate levels were evaluated retrospectively in children seen in our paediatric national reference centre for hypersomnia. The cohort included 23 control subjects (11.5 ± 4 years, 43% boys) and 51 patients presenting de-novo narcolepsy (N) (12.7 ± 3.7 years, 47% boys). In narcoleptic children, cataplexy was present in 78% and DQB1*0602 was positive in 96%. The control children were less obese (2 versus 47%, P = 0.001). Compared with control subjects, narcoleptic children had higher bicarbonate levels (P = 0.02) as well as higher PCO2 (P < 0.01) and lower venous pH gas (P < 0.01). Bicarbonate levels higher than 27 mmol L(-1) were found in 41.2% of the narcoleptic children and 4.2% of the controls (P = 0.001). Bicarbonate levels were correlated with the Adapted Epworth Sleepiness Scale (P = 0.01). Narcoleptic patients without obesity often had bicarbonate levels higher than 27 mmol L (-1) (55 versus 25%, P = 0.025). No differences were found between children with and without cataplexy. In conclusion, narcoleptic patients had higher bicarbonate plasma levels compared to control children. This result could be a marker of hypoventilation in this pathology, provoking an increase in PCO2 and therefore a respiratory acidosis, compensated by an increase in plasma bicarbonates. This simple screening tool could be useful for prioritizing children for sleep laboratory evaluation in practice. © 2015 European Sleep Research Society.

  6. Vision in high-level football officials.

    Science.gov (United States)

    Baptista, António Manuel Gonçalves; Serra, Pedro M; McAlinden, Colm; Barrett, Brendan T

    2017-01-01

    Officiating in football depends, at least to some extent, upon adequate visual function. However, there is no vision standard for football officiating and the nature of the relationship between officiating performance and level of vision is unknown. As a first step in characterising this relationship, we report on the clinically-measured vision and on the perceived level of vision in elite-level, Portuguese football officials. Seventy-one referees (R) and assistant referees (AR) participated in the study, representing 92% of the total population of elite level football officials in Portugal in the 2013/2014 season. Nine of the 22 Rs (40.9%) and ten of the 49 ARs (20.4%) were international-level. Information about visual history was also gathered. Perceived vision was assessed using the preference-values-assigned-to-global-visual-status (PVVS) and the Quality-of-Vision (QoV) questionnaire. Standard clinical vision measures (including visual acuity, contrast sensitivity and stereopsis) were gathered in a subset (n = 44, 62%) of the participants. Data were analysed according to the type (R/AR) and level (international/national) of official, and Bonferroni corrections were applied to reduce the risk of type I errors. Adopting criterion for statistical significance of pfootball officials were similar to published normative values for young, adult populations and similar between R and AR. Clinically-measured vision did not differ according to officiating level. Visual acuity measured with and without a pinhole disc indicated that around one quarter of participants may be capable of better vision when officiating, as evidenced by better acuity (≥1 line of letters) using the pinhole. Amongst the clinical visual tests we used, we did not find evidence for above-average performance in elite-level football officials. Although the impact of uncorrected mild to moderate refractive error upon officiating performance is unknown, with a greater uptake of eye examinations, visual

  7. The measurement of trace elements in interplanetary dust and cometary particles by ultra-high sensitivity INAA

    International Nuclear Information System (INIS)

    Zolensky, M.E.; Lindstrom, D.J.; Lindstrom, R.M.; Lindstrom, M.M.

    1989-01-01

    Today the major elemental composition of interplanetary dust particles (IDPs) is routinely determined in many laboratories. These and mineralogical studies have revealed the presence of at least two major types of IDPs, chondritic and refractory. Preliminary results of a successful attempt to determine abundances of a large suite of trace elements from both chondritic and refractory IDPs are reported. The analytical procedure can be used in the grain-by-grain analysis of returned cometary samples. Chondritic and refractory IDPs are characterized by standard scanning electron microscopy and energy dispersive x ray spectroscopy (SEM-EDX) techniques. With this system, detection limits for many elements are well below picogram levels, and some approach femtogram levels. This technique is non-destructive, although some sample handling is required, so particles can be analyzed by other techniques after instrument neutron activation analysis (INAA) is completed. Data is presently being reduced from the analyses of 7 IDPs. These are U2015E10, U2015F1, W7029-A2, W7029-A3, W7013A8, LACl (all chondritic) and 705 (refractory). So far, 17 different major and trace elements were detected and measured in these particles, including rare earths and some very volatile elements (Br and Zn)

  8. Simultaneous determination of trace amounts of metals by high-performance liquid chromatography after preconcentration with adsorption on chlorotrifluoroethylene polymer as their hexamethylenedithiocarbamate complexes

    International Nuclear Information System (INIS)

    Shijo, Yoshio; Yoshida, Hideaki; Uehara, Nobuo; Kitamura, Teruo; Yoshimoto, Eiji.

    1996-01-01

    A method for the simultaneous determination of Bi, Cd, Cu, In, Ni and Pb by high-performance liquid chromatography is presented. These metals are preconcentrated on poly(chlorotrifluoroethylene) resin particles as their hexamethylenedithiocarbamate (HMDC) complexes, and eluted with dimethyl sulfoxide, followed by HPLC separation and determination using an ODS column. The conditions for the adsorption of metal-HMDC complexes, such as the pH, HMDC concentration, amount of the resin particles and elution times with dimethyl sulfoxide, are discussed. The resulting solution is suitable for injection into reversed-phase HPLC. The detection limits for the metals were found to be at sub μgl -1 levels. The application of this principle to the trace analysis of Bi, Cd, Cu, In, Ni and Pb in high-purity aluminum is demonstrated. (author)

  9. Vision in high-level football officials.

    Directory of Open Access Journals (Sweden)

    António Manuel Gonçalves Baptista

    Full Text Available Officiating in football depends, at least to some extent, upon adequate visual function. However, there is no vision standard for football officiating and the nature of the relationship between officiating performance and level of vision is unknown. As a first step in characterising this relationship, we report on the clinically-measured vision and on the perceived level of vision in elite-level, Portuguese football officials. Seventy-one referees (R and assistant referees (AR participated in the study, representing 92% of the total population of elite level football officials in Portugal in the 2013/2014 season. Nine of the 22 Rs (40.9% and ten of the 49 ARs (20.4% were international-level. Information about visual history was also gathered. Perceived vision was assessed using the preference-values-assigned-to-global-visual-status (PVVS and the Quality-of-Vision (QoV questionnaire. Standard clinical vision measures (including visual acuity, contrast sensitivity and stereopsis were gathered in a subset (n = 44, 62% of the participants. Data were analysed according to the type (R/AR and level (international/national of official, and Bonferroni corrections were applied to reduce the risk of type I errors. Adopting criterion for statistical significance of p<0.01, PVVS scores did not differ between R and AR (p = 0.88, or between national- and international-level officials (p = 0.66. Similarly, QoV scores did not differ between R and AR in frequency (p = 0.50, severity (p = 0.71 or bothersomeness (p = 0.81 of symptoms, or between international-level vs national-level officials for frequency (p = 0.03 or bothersomeness (p = 0.07 of symptoms. However, international-level officials reported less severe symptoms than their national-level counterparts (p<0.01. Overall, 18.3% of officials had either never had an eye examination or if they had, it was more than 3 years previously. Regarding refractive correction, 4.2% had undergone refractive surgery and

  10. Statistics of high-level scene context.

    Science.gov (United States)

    Greene, Michelle R

    2013-01-01

    CONTEXT IS CRITICAL FOR RECOGNIZING ENVIRONMENTS AND FOR SEARCHING FOR OBJECTS WITHIN THEM: contextual associations have been shown to modulate reaction time and object recognition accuracy, as well as influence the distribution of eye movements and patterns of brain activations. However, we have not yet systematically quantified the relationships between objects and their scene environments. Here I seek to fill this gap by providing descriptive statistics of object-scene relationships. A total of 48, 167 objects were hand-labeled in 3499 scenes using the LabelMe tool (Russell et al., 2008). From these data, I computed a variety of descriptive statistics at three different levels of analysis: the ensemble statistics that describe the density and spatial distribution of unnamed "things" in the scene; the bag of words level where scenes are described by the list of objects contained within them; and the structural level where the spatial distribution and relationships between the objects are measured. The utility of each level of description for scene categorization was assessed through the use of linear classifiers, and the plausibility of each level for modeling human scene categorization is discussed. Of the three levels, ensemble statistics were found to be the most informative (per feature), and also best explained human patterns of categorization errors. Although a bag of words classifier had similar performance to human observers, it had a markedly different pattern of errors. However, certain objects are more useful than others, and ceiling classification performance could be achieved using only the 64 most informative objects. As object location tends not to vary as a function of category, structural information provided little additional information. Additionally, these data provide valuable information on natural scene redundancy that can be exploited for machine vision, and can help the visual cognition community to design experiments guided by statistics

  11. Socio-demographic, lifestyle, and dietary determinants of essential and possibly-essential trace element levels in adipose tissue from an adult cohort.

    Science.gov (United States)

    Rodríguez-Pérez, Celia; Vrhovnik, Petra; González-Alzaga, Beatriz; Fernández, Mariana F; Martin-Olmedo, Piedad; Olea, Nicolás; Fiket, Željka; Kniewald, Goran; Arrebola, Juan P

    2018-05-01

    There is increasing evidence linking levels of trace elements (TEs) in adipose tissue with certain chronic conditions (e.g., diabetes or obesity). The objectives of this study were to assess concentrations of a selection of nine essential and possibly-essential TEs in adipose tissue samples from an adult cohort and to explore their socio-demographic, dietary, and lifestyle determinants. Adipose tissue samples were intraoperatively collected from 226 volunteers recruited in two public hospitals from Granada province. Trace elements (Co, Cr, Cu, Fe, Mn, Mo, Se, V, and Zn) were analyzed in adipose tissue by high-resolution inductively coupled plasma mass spectrometry (HR-ICP-MS). Data were collected on socio-demographic characteristics, lifestyle, diet, and health status by face-to-face interview. Predictors of TE concentrations were assessed by using multivariable linear and logistic regression. All TEs were detected in all samples with the exception of Se (53.50%). Iron, zinc, and copper showed the highest concentrations (42.60 mg/kg, 9.80 mg/kg, and 0.68 mg/kg, respectively). Diet was the main predictor of Cr, Fe, Mo, and Se concentrations. Body mass index was negatively associated with all TEs (β coefficients = -0.018 to -0.593, p = 0.001-0.090) except for Mn and V. Age showed a borderline-significant positive correlation with Cu (β = 0.004, p = 0.089). Residence in a rural or semi-rural area was associated with increased Co, Cr, Fe, Mo, Mn, V and Zn concentrations and with β coefficients ranging from 0.196 to 0.544 (p V concentrations (β coefficients = 0.276-0.368, p = 0.022-0.071). This is the first report on the distribution of these TEs in adipose tissue and on their determinants in a human cohort and might serve as an initial step in the elucidation of their clinical relevance. Copyright © 2017 Elsevier Ltd. All rights reserved.

  12. Progress in the High Level Trigger Integration

    CERN Multimedia

    Cristobal Padilla

    2007-01-01

    During the week from March 19th to March 23rd, the DAQ/HLT group performed another of its technical runs. On this occasion the focus was on integrating the Level 2 and Event Filter triggers, with a much fuller integration of HLT components than had been done previously. For the first time this included complete trigger slices, with a menu to run the selection algorithms for muons, electrons, jets and taus at the Level-2 and Event Filter levels. This Technical run again used the "Pre-Series" system (a vertical slice prototype of the DAQ/HLT system, see the ATLAS e-news January issue for details). Simulated events, provided by our colleagues working in the streaming tests, were pre-loaded into the ROS (Read Out System) nodes. These are the PC's where the data from the detector is stored after coming out of the front-end electronics, the "first part of the TDAQ system" and the interface to the detectors. These events used a realistic beam interaction mixture and had been subjected to a Level-1 selection. The...

  13. Effect of climate conditions on the uptake and translocation of trace elements in plants an behavior of ions at cell level

    International Nuclear Information System (INIS)

    Yamagami, Mutsumi; Yanai, Masumi; Hisamatsu, Shun'ichi; Inaba, Jiro

    2003-01-01

    The present investigation was performed in order to look at the effect of various climatic conditions on the uptake and translocation of radionuclides and trace elements in plants. So far we have investigated the following three items; the effect of climate conditions including Yamase (seasonal climatic condition of low temperature, low sunshine and high humidity.) on the elemental transfer factors in rice, the effect of light conditions on the metabolism of elements in plants, and the effect of environmental factors on elemental movement at a cell level, and searched for mutant plant strains to match the elemental requirement. Among these items this paper elaborates about the effect of light condition on the metabolism of elements in plants. Young radishes (Raphanus sativus L.) were grown under various light conditions; white, blue+red and red fluorescent light. Under red light a marked spindly growth of the stem and petiole was observed. Adding blue light to red light reduced the growth to the level under control white light. The concentrations of elements, such as Fe, Cu and Zn, in the plants were affected by the light conditions. The effect of light condition on the spindly growth of hypocotyls with the plant was also studied with Arabidopsis (Arabidopsis thaliana L.), and the results showed that supplementation of blue light approximately 15% red light could control the growth. For a further investigation of the mechanism of these phenomena, several ion channel blockers and metabolic inhibitors were examined in hydroponic plants or protoplasts. The results suggested that both anion and cation channels were related to the elongation. (author)

  14. Long-term memory traces for language sounds are highly context-sensitive: an MEG/ERF study

    DEFF Research Database (Denmark)

    Nielsen, Andreas Højlund; Gebauer, Line; Mcgregor, William

    impact on the proposed long-term memory traces for native phonological categories. In order to generate different MMF responses to the same language sound contrast depending on the phonetic context, these long-term memory traces must thus be context-sensitive themselves or exist as separate traces...

  15. Ultra-light and flexible pencil-trace anode for high performance potassium-ion and lithium-ion batteries

    Directory of Open Access Journals (Sweden)

    Zhixin Tai

    2017-07-01

    Full Text Available Engineering design of battery configurations and new battery system development are alternative approaches to achieve high performance batteries. A novel flexible and ultra-light graphite anode is fabricated by simple friction drawing on filter paper with a commercial 8B pencil. Compared with the traditional anode using copper foil as current collector, this innovative current-collector-free design presents capacity improvement of over 200% by reducing the inert weight of the electrode. The as-prepared pencil-trace electrode exhibits excellent rate performance in potassium-ion batteries (KIBs, significantly better than in lithium-ion batteries (LIBs, with capacity retention of 66% for the KIB vs. 28% for the LIB from 0.1 to 0.5 A g−1. It also shows a high reversible capacity of ∼230 mAh g−1 at 0.2 A g−1, 75% capacity retention over 350 cycles at 0.4 A g−1and the highest rate performance (based on the total electrode weight among graphite electrodes for K+ storage reported so far. Keywords: Current-collector-free, Flexible pencil-trace electrode, Potassium-ion battery, Lithium-ion battery, Layer-by-layer interconnected architecture

  16. Period analysis at high noise level

    International Nuclear Information System (INIS)

    Kovacs, G.

    1980-01-01

    Analytical expressions are derived for the variances of some types of the periodograms due to normal-distributed noise present in the data. The equivalence of the Jurkevich and the Warner and Robinson methods is proved. The optimum phase cell number of the Warner and Robinson method is given; this number depends on the data length, signal form and noise level. The results are illustrated by numerical examples. (orig.)

  17. Monitoring of trace-levels of herbicides in the Cachoeira River in Bahia State, Brazil, by neutron activation analysis

    International Nuclear Information System (INIS)

    Severo, Maria Isabel; Oliveira, Eduardo; Caribe, Ana Cristina; Revel, Gilles; Oliveira, Arno Heeren

    1995-01-01

    A systematic study was undertaken in order to find out which of the most relevant elements can be determined in water normal conditions by non-destructive neutron activation and a suitable mono standard method. Standardized water from Cachoeira river and croustaceous samples were brought to dryness by freeze-drying and irradiated in quartz at a neutron flux of 10 14 cm -2 s -1 . Trace element contents in quartz ampoules from different origins were determined separately. The following elements were preliminarily identified: Cr, Co, Cu, Br, Sb, Cs, Ce, Nb, Au, Pa, Zn, La, Sm. (author). 10 refs., 2 tabs

  18. Outcrop-scale fracture trace identification using surface roughness derived from a high-density point cloud

    Science.gov (United States)

    Okyay, U.; Glennie, C. L.; Khan, S.

    2017-12-01

    Owing to the advent of terrestrial laser scanners (TLS), high-density point cloud data has become increasingly available to the geoscience research community. Research groups have started producing their own point clouds for various applications, gradually shifting their emphasis from obtaining the data towards extracting more and meaningful information from the point clouds. Extracting fracture properties from three-dimensional data in a (semi-)automated manner has been an active area of research in geosciences. Several studies have developed various processing algorithms for extracting only planar surfaces. In comparison, (semi-)automated identification of fracture traces at the outcrop scale, which could be used for mapping fracture distribution have not been investigated frequently. Understanding the spatial distribution and configuration of natural fractures is of particular importance, as they directly influence fluid-flow through the host rock. Surface roughness, typically defined as the deviation of a natural surface from a reference datum, has become an important metric in geoscience research, especially with the increasing density and accuracy of point clouds. In the study presented herein, a surface roughness model was employed to identify fracture traces and their distribution on an ophiolite outcrop in Oman. Surface roughness calculations were performed using orthogonal distance regression over various grid intervals. The results demonstrated that surface roughness could identify outcrop-scale fracture traces from which fracture distribution and density maps can be generated. However, considering outcrop conditions and properties and the purpose of the application, the definition of an adequate grid interval for surface roughness model and selection of threshold values for distribution maps are not straightforward and require user intervention and interpretation.

  19. Activation analysis of trace amounts of rare earth in high purity tantalum

    International Nuclear Information System (INIS)

    Ishibashi, Wataru; Saito, Shinichi; Hirayama, Tooru.

    1975-01-01

    It is necessary to separate rare earth from tantalum by rapid methods in order to remove effects of a strong radioactivity and a short half-life. Tantalum is extracted with 10%N-lauryl (trialkylmethyl) amino-benzene pre-equilibrated with a solution of 9 M hydrochloric and 0.15 M hydrofluoric acid. A non-radioactive rare earth element is added to this aqueous solution, a precipitate of trace amounts of radioactive rare earth in aqueous solution is formed by this addition of rare earth. Some factors in the determination are: 1) the effect of the irradiation position of the sample in the atomic reactor, 2) the effect on the extraction with 10%N-lauryl (trialkylmethyl) amino-benzene for the radioactive rare earth, 3) the effect of the concentration of hydrofluoric acid, ammonia water and nitric acid on co-precipitation. As a result of the investigation we obtained the following satisfactory results: 1) Rare earth was not effected by the extraction of tantalum with 10%N-lauryl (trialkylmethyl) amino-benzene. 2) The recovery of rare earth by co-precipitation increases when an ammonium ion coexists, and when the concentration of hydrofluoric acid decreases, but the recovery decreases with the increase of nitric acid concentration. 3) The time required for the extraction is 9 hours. In case of determination for dysprosium, tantalum extracted with 10%N-lauryl (trialkylmethyl) amino-benzene before activation and the time for separation is 2 hours. (auth.)

  20. Disposal of high-level radioactive wastes

    Energy Technology Data Exchange (ETDEWEB)

    Costello, J M [Australian Atomic Energy Commission Research Establishment, Lucas Heights

    1982-03-01

    The aims and options for the management and disposal of highly radioactive wastes contained in spent fuel from the generation of nuclear power are outlined. The status of developments in reprocessing, waste solidification and geologic burial in major countries is reviewed. Some generic assessments of the potential radiological impacts from geologic repositories are discussed, and a perspective is suggested on risks from radiation.

  1. High-lying 0+ and 3- levels in 12C

    International Nuclear Information System (INIS)

    Hanna, S.S.; Feldman, W.; Suffert, M.; Kurath, D.

    1982-01-01

    The γ decays of the levels at 17.77 and 18.36 MeV in 12 C are studied by proton capture and the assignments of (0 + ,1) and (3 - ,1), respectively, are confirmed. The very great strength of the decay of the (0 + ,1) level to the lower (1 + ,0) level at 12.71 MeV is consistent with a spin- and isospin-flip deuteronlike transition. The strong decay of the (3 - ,1) level to the lower (3 - 0,) level at 9.64 MeV is fairly typical of an analog to antianalog transition. The γ-decay widths of these levels are compared with shell-model calculations

  2. Transplantation of epiphytic bioaccumulators (Tillandsia capillaris) for high spatial resolution biomonitoring of trace elements and point sources deconvolution in a complex mining/smelting urban context

    Science.gov (United States)

    Goix, Sylvaine; Resongles, Eléonore; Point, David; Oliva, Priscia; Duprey, Jean Louis; de la Galvez, Erika; Ugarte, Lincy; Huayta, Carlos; Prunier, Jonathan; Zouiten, Cyril; Gardon, Jacques

    2013-12-01

    Monitoring atmospheric trace elements (TE) levels and tracing their source origin is essential for exposure assessment and human health studies. Epiphytic Tillandsia capillaris plants were used as bioaccumulator of TE in a complex polymetallic mining/smelting urban context (Oruro, Bolivia). Specimens collected from a pristine reference site were transplanted at a high spatial resolution (˜1 sample/km2) throughout the urban area. About twenty-seven elements were measured after a 4-month exposure, also providing new information values for reference material BCR482. Statistical power analysis for this biomonitoring mapping approach against classical aerosols surveys performed on the same site showed the better aptitude of T. Capillaris to detect geographical trend, and to deconvolute multiple contamination sources using geostatistical principal component analysis. Transplanted specimens in the vicinity of the mining and smelting areas were characterized by extreme TE accumulation (Sn > Ag > Sb > Pb > Cd > As > W > Cu > Zn). Three contamination sources were identified: mining (Ag, Pb, Sb), smelting (As, Sn) and road traffic (Zn) emissions, confirming results of previous aerosol survey.

  3. Highly efficient removal of trace thallium from contaminated source waters with ferrate: Role of in situ formed ferric nanoparticle.

    Science.gov (United States)

    Liu, Yulei; Wang, Lu; Wang, Xianshi; Huang, Zhuangsong; Xu, Chengbiao; Yang, Tao; Zhao, Xiaodan; Qi, Jingyao; Ma, Jun

    2017-11-01

    Thallium (Tl) is highly toxic to mammals and relevant pollution cases are increasing world-widely. Convenient and efficient method for the removal of trace Tl from contaminated source water is imperative. Here, the removal of trace Tl by K 2 FeO 4 [Fe(VI)] was investigated for the first time, with the exploration of reaction mechanisms. Six different types of water treatment agents (powdered activated carbon, Al 2 (SO 4 ) 3 , FeCl 3 , δ-MnO 2 , MnO 2 nano-particles, and K 2 FeO 4 ) were used for the removal of Tl in spiked river water, and K 2 FeO 4 showed excellent removal performance. Over 92% of Tl (1 μg/L) was removed within 5 min by applying 2.5 mg/L of K 2 FeO 4 (pH 7.0, 20 °C). XPS analysis revealed that in the reaction of Tl(I) with K 2 FeO 4 , Tl(I) was oxidized to Tl(III), and removed by the K 2 FeO 4 reduced ferric particles. The removal of Tl by in situ formed and ex situ formed ferric particle was examined respectively, and the results revealed that the removal of trace Tl could be attributed to the combination of adsorption and coprecipitation processes. The hydrodynamic size of the reduced particle from K 2 FeO 4 ranged from 10 nm to 100 nm, and its surface was negatively charged under neutral pH condition. These factors were conducive for the efficient removal of Tl by K 2 FeO 4 . The effects of solution pH, coexisting ions (Na + , Ca 2+ , and HCO 3 - ), humic acid, solution temperature, and reductive environment on the removal and desorption of Tl were investigated, and the elimination of Tl in polluted river water and reservoir water was performed. These results suggest that K 2 FeO 4 could be an efficient and convenient agent on trace Tl removal. Copyright © 2017. Published by Elsevier Ltd.

  4. How healthy is urban horticulture in high traffic areas? Trace metal concentrations in vegetable crops from plantings within inner city neighbourhoods in Berlin, Germany.

    Science.gov (United States)

    Säumel, Ina; Kotsyuk, Iryna; Hölscher, Marie; Lenkereit, Claudia; Weber, Frauke; Kowarik, Ingo

    2012-06-01

    Food production by urban dwellers is of growing importance in developing and developed countries. Urban horticulture is associated with health risks as crops in urban settings are generally exposed to higher levels of pollutants than those in rural areas. We determined the concentration of trace metals in the biomass of different horticultural crops grown in the inner city of Berlin, Germany, and analysed how the local setting shaped the concentration patterns. We revealed significant differences in trace metal concentrations depending on local traffic, crop species, planting style and building structures, but not on vegetable type. Higher overall traffic burden increased trace metal content in the biomass. The presence of buildings and large masses of vegetation as barriers between crops and roads reduced trace metal content in the biomass. Based on this we discuss consequences for urban horticulture, risk assessment, and planting and monitoring guidelines for cultivation and consumption of crops. Copyright © 2012 Elsevier Ltd. All rights reserved.

  5. Trace analysis measurements in high-purity aluminium by means of radiochemical neutron and proton activation analysis

    International Nuclear Information System (INIS)

    Egger, K.P.

    1987-01-01

    The aim of the study consisted in the development of efficient radiochemical composite processes and activation methods for the multi-element determination of traces within the lower ng range in high-purity aluminium. More than 50 elements were determined with the help of activation with reactor neutrons; the selective separation of matrix activity (adsorption with hydrated antimony pentoxide) led to a noticeable improvement of detectability, as compared with instrumental neutron activation analysis. Further improvements were achieved with the help of radiochemical group separations in ion exchangers or with the help of the selective separation of the pure beta-emitting elements. Over 20 elements up to high atomic numbers were determined by means of activating 13 MeV protons and 23 Me protons. In this connection, improvements of the detection limit by as a factor of 10 were achieved with radiochemical separation techniques, as compared with pure instrumental proton activation analysis. (RB) [de

  6. High level radiation dosimetry in biomedical research

    International Nuclear Information System (INIS)

    Inada, Tetsuo

    1979-01-01

    The physical and biological dosimetries relating to cancer therapy with radiation were taken up at the first place in the late intercomparison on high LET radiation therapy in Japan-US cancer research cooperative study. The biological dosimetry, the large dose in biomedical research, the high dose rate in biomedical research and the practical dosimeters for pulsed neutrons or protons are outlined with the main development history and the characteristics which were obtained in the relating experiments. The clinical neutron facilities in the US and Japan involved in the intercomparison are presented. Concerning the experimental results of dosimeters, the relation between the R.B.E. compared with Chiba (Cyclotron in National Institute of Radiological Sciences) and the energy of deuterons or protons used for neutron production, the survival curves of three cultured cell lines derived from human cancers, after the irradiation of 250 keV X-ray, cyclotron neutrons of about 13 MeV and Van de Graaff neutrons of about 2 MeV, the hatchability of dry Artemia eggs at the several depths in an absorber stack irradiated by 60 MeV proton beam of 40, 120 and 200 krad, the peak skin reaction of mouse legs observed at various sets of average and instantaneous dose rates, and the peak skin reaction versus three instantaneous dose rates at fixed average dose rate of 7,300 rad/min are shown. These actual data were evaluated numerically and in relation to the physical meaning from the viewpoint of the fundamental aspect of cancer therapy, comparing the Japanese measured values to the US data. The discussion record on the high dose rate effect of low LET particles on biological substances and others is added. (Nakai, Y.)

  7. Energy levels of highly ionized atoms

    International Nuclear Information System (INIS)

    Martin, W.C.

    1981-01-01

    Most of the data reviewed here were derived from spectra photographed in the wavelength range from 600 A down to about 20 A (approx. 20 to 600 eV). Measurements with uncertainties less than 0.001 A relative to appropriate standard wavelengths can be made with high-resolution diffraction-grating spectroscopy over most of the vacuum-ultraviolet region. Although this uncertainty corresponds to relative errors of 1 part per million (ppM) at 1000 A and 20 ppM at 50 A, measurements with uncertainties smaller than 0.001 A would generally require more effort at the shorter wavelengths, mainly because of the sparsity of accurate standards. Even where sufficiently numerous and accurate standards are available, the accuracy of measurements of the spectra of very high temperature plasmas is limited by Doppler broadening and, in some cases, other plasma effects. Several sources of error combine to give total estimated errors ranging from 10 to 1000 ppM for the experimental wavelengths of interest here. It will be seen, however, that with the possible exception of a few fine-structure splittings the experimental errors are small compared to the errors of the relevant theoretical calculations

  8. The High Level Vibration Test Program

    International Nuclear Information System (INIS)

    Hofmayer, C.H.; Curreri, J.R.; Park, Y.J.; Kato, W.Y.; Kawakami, S.

    1989-01-01

    As part of cooperative agreements between the United States and Japan, tests have been performed on the seismic vibration table at the Tadotsu Engineering Laboratory of Nuclear Power Engineering Test Center (NUPEC) in Japan. The objective of the test program was to use the NUPEC vibration table to drive large diameter nuclear power piping to substantial plastic strain with an earthquake excitation and to compare the results with state-of-the-art analysis of the problem. The test model was designed by modifying the 1/2.5 scale model of the PWR primary coolant loop. Elastic and inelastic seismic response behavior of the test model was measured in a number of test runs with an increasing excitation input level up to the limit of the vibration table. In the maximum input condition, large dynamic plastic strains were obtained in the piping. Crack initiation was detected following the second maximum excitation run. The test model was subjected to a maximum acceleration well beyond what nuclear power plants are designed to withstand. This paper describes the overall plan, input motion development, test procedure, test results and comparisons with pre-test analysis. 4 refs., 16 figs., 2 tabs

  9. The High Level Vibration Test program

    International Nuclear Information System (INIS)

    Hofmayer, C.H.; Curreri, J.R.; Park, Y.J.; Kato, W.Y.; Kawakami, S.

    1990-01-01

    As part of cooperative agreements between the United States and Japan, tests have been performed on the seismic vibration table at the Tadotsu Engineering Laboratory of Nuclear Power Engineering Test Center (NUPEC) in Japan. The objective of the test program was to use the NUPEC vibration table to drive large diameter nuclear power piping to substantial plastic strain with an earthquake excitation and to compare the results with state-of-the-art analysis of the problem. The test model was designed by modifying the 1/2.5 scale model of the pressurized water reactor primary coolant loop. Elastic and inelastic seismic response behavior of the test model was measured in a number of test runs with an increasing excitation input level up to the limit of the vibration table. In the maximum input condition, large dynamic plastic strains were obtained in the piping. Crack initiation was detected following the second maximum excitation run. The test model was subjected to a maximum acceleration well beyond what nuclear power plants are designed to withstand. This paper describes the overall plan, input motion development, test procedure, test results and comparisons with pre-test analysis

  10. Trace-Level Screening of Chemicals Related to Clandestine Desomorphine Production with Ambient Sampling, Portable Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Seth E. Hall

    2017-01-01

    Full Text Available Desomorphine is a semisynthetic opioid that is responsible for the psychoactive effects of a dangerous homemade injectable mixture that goes by street name “Krokodil.” Desorption electrospray ionization (DESI and paper spray ionization (PSI are implemented on a portable mass spectrometer for the direct analysis of desomorphine and precursor reagent codeine from multiple substrates of potential relevance to clandestine drug laboratory synthesis and paraphernalia seizure. Minimal sample preparation required for analysis and portability of the instrument suggest the potential for rapid, on-site analysis of evidence, a highly desired benefit for forensic science and law enforcement practitioners. Both DESI-MS and PSI-MS can generate spectra consistent with preceding data obtained using traditional ionization methods, while demonstrating detection limits in the low- to sub-ng levels.

  11. Heat transfer in high-level waste management

    International Nuclear Information System (INIS)

    Dickey, B.R.; Hogg, G.W.

    1979-01-01

    Heat transfer in the storage of high-level liquid wastes, calcining of radioactive wastes, and storage of solidified wastes are discussed. Processing and storage experience at the Idaho Chemical Processing Plant are summarized for defense high-level wastes; heat transfer in power reactor high-level waste processing and storage is also discussed

  12. Managing commercial high-level radioactive waste

    International Nuclear Information System (INIS)

    1983-01-01

    The article is a summary of issues raised during US Congress deliberations on nuclear waste policy legislation. It is suggested that, if history is not to repeat itself, and the current stalemate on nuclear waste is not to continue, a comprehensive policy is needed that addresses the near-term problems of interim storage as part of an explicit and credible program for dealing with the longer term problem of developing a final isolation system. Such a policy must: 1) adequately address the concerns and win the support of all the major interested parties, and 2) adopt a conservative technical and institutional approach - one that places high priority on avoiding the problems that have repeatedly beset the program in the past. It is concluded that a broadly supported comprehensive policy would contain three major elements, each designed to address one of the key questions concerning Federal credibility: commitment in law to the goals of a comprehensive policy; credible institutional mechanisms for meeting goals; and credible measures for addressing the specific concerns of the states and the various publics. Such a policy is described in detail. (Auth.)

  13. Bumblebee pupae contain high levels of aluminium.

    Science.gov (United States)

    Exley, Christopher; Rotheray, Ellen; Goulson, David

    2015-01-01

    The causes of declines in bees and other pollinators remains an on-going debate. While recent attention has focussed upon pesticides, other environmental pollutants have largely been ignored. Aluminium is the most significant environmental contaminant of recent times and we speculated that it could be a factor in pollinator decline. Herein we have measured the content of aluminium in bumblebee pupae taken from naturally foraging colonies in the UK. Individual pupae were acid-digested in a microwave oven and their aluminium content determined using transversely heated graphite furnace atomic absorption spectrometry. Pupae were heavily contaminated with aluminium giving values between 13.4 and 193.4 μg/g dry wt. and a mean (SD) value of 51.0 (33.0) μg/g dry wt. for the 72 pupae tested. Mean aluminium content was shown to be a significant negative predictor of average pupal weight in colonies. While no other statistically significant relationships were found relating aluminium to bee or colony health, the actual content of aluminium in pupae are extremely high and demonstrate significant exposure to aluminium. Bees rely heavily on cognitive function and aluminium is a known neurotoxin with links, for example, to Alzheimer's disease in humans. The significant contamination of bumblebee pupae by aluminium raises the intriguing spectre of cognitive dysfunction playing a role in their population decline.

  14. Flowsheet development studies for the decontamination of high-activity-level water at Three Mile Island Unit 2

    International Nuclear Information System (INIS)

    Collins, E.D.; Bigelow, J.E.; Campbell, D.O.; King, L.J.; Knauer, J.B.

    1980-01-01

    Several chemical processing flowsheets were considered for the decontamination of high-activity-level water at the Three Mile Island (TMI) Unit 2. A zeolite ion exchange process was evaluated and recommended for absorption of the bulk of the highly radioactive cesium and strontium. Standard organic ion-exchange resins were selected to remove the remaining traces of radioactive nuclides (except tritium which cannot be removed by any practical process). Process conditions were evaluated using both synthetic, tracer-level solutions and samples of actual, high-activity level water from TMI Unit 2

  15. High sensitivity detection and characterization of the chemical state of trace element contamination on silicon wafers

    CERN Document Server

    Pianetta, Piero A; Baur, K; Brennan, S; Homma, T; Kubo, N

    2003-01-01

    Increasing the speed and complexity of semiconductor integrated circuits requires advanced processes that put extreme constraints on the level of metal contamination allowed on the surfaces of silicon wafers. Such contamination degrades the performance of the ultrathin SiO sub 2 gate dielectrics that form the heart of the individual transistors. Ultimately, reliability and yield are reduced to levels that must be improved before new processes can be put into production. It should be noted that much of this metal contamination occurs during the wet chemical etching and rinsing steps required for the manufacture of integrated circuits and industry is actively developing new processes that have already brought the metal contamination to levels beyond the measurement capabilities of conventional analytical techniques. The measurement of these extremely low contamination levels has required the use of synchrotron radiation total reflection X-ray fluorescence (SR-TXRF) where sensitivities 100 times better than conv...

  16. Determination of elemental concentrations at trace levels in alumina by charged particle activation analysis using proton beam from VEC accelerator

    International Nuclear Information System (INIS)

    Datta, J.; Dasgupta, S.; Chowdhury, D.P.; Verma, R.

    2015-01-01

    The elemental impurities have been determined in high purity alumina material used in nuclear reactors at ppb (μg kg -1 ) to ppm (mg kg -1 ) levels by CPAA using proton beam from VEC machine. Proton beam has the advantage of high cross section for (p, n) reaction to produce suitable nuclide for activation analysis by instrumental approach. The cross sections of higher reaction channels like (p, 2n), (p, pn) are found to be less than 1 mb below 13 MeV proton by theoretical calculation using ALICE 91 computer code. Therefore, 13 MeV proton beam was used to irradiate the alumina samples along with standards, Lake (IAEA-SL -1 ) and Marine (PACS-2) sediments, both in pellet and powder forms. The irradiation was carried out with 50 nA to 1μA beam current for 10 min to 10 h depending on types of samples and standards. The beam current was measured by Faraday cup and also checked by putting Ti monitoring foil before the target. Ni is determined by (p, pn) reaction using 18 MeV proton as there is no suitable product from (p, n) reaction. The counting measurements of irradiated samples were performed with a high resolution γ-spectrometer using HPGe detector (relative efficiency - 40%, resolution - 2.0 keV at 1332 keV) coupled to a PC based 8 k MCA. The validation of the CPAA results has been carried out by INAA with the same alumina samples, carried out in Dhruva reactor with neutron flux 10 14 cm 2 s -1 using standards IAEA-SL-1 and PACS-2

  17. Recent developments in automated determinations of trace level concentrations of elements and on-line fractionations schemes exploiting the micro-sequential injection - lab-on-valve approach

    DEFF Research Database (Denmark)

    Hansen, Elo Harald; Miró, Manuel; Long, Xiangbao

    2006-01-01

    The determination of trace level concentrations of elements, such as metal species, in complex matrices by atomic absorption or emission spectrometric methods often require appropriate pretreatments comprising separation of the analyte from interfering constituents and analyte preconcentration...... are presented as based on the exploitation of micro-sequential injection (μSI-LOV) using hydrophobic as well as hydrophilic bead materials. The examples given comprise the presentation of a universal approach for SPE-assays, front-end speciation of Cr(III) and Cr(VI) in a fully automated and enclosed set...

  18. Analytical study of a gas of gluonic quasiparticles at high temperature: Effective mass, pressure, and trace anomaly

    International Nuclear Information System (INIS)

    Giacosa, Francesco

    2011-01-01

    The thermodynamical properties of a pure Yang-Mills theory SU(N) is described by a gas of gluonic quasiparticles with temperature-dependent mass m(T) and a bag function B(T). The analytic behavior of m(T) and the pressure p in the temperature range 2.5-5T c are derived and constraints on the parameters defining B(T) are discussed. The trace anomaly θ=ρ-3p is evaluated in the high T domain: it is dominated by a quadratic behavior θ=nKT 2 , where n=2(N 2 -1) is the number of degrees of freedom and K is an integration constant which does not depend on the bag function B(T). The quadratic rise of θ is in good agreement with recent lattice simulations.

  19. Handling and storage of high-level liquid wastes from reprocessing of spent fuel

    International Nuclear Information System (INIS)

    Finsterwalder, L.

    1982-01-01

    The high level liquid wastes arise from the reprocessing of irradiated nuclear fuels, which are dissolved in aqueous acid solution, and the plutonium and unburned uranium removed in the chemical separation plant. The remaining solution, containing more than 99% of the dissolved fission products, together with impurities from cladding materials, corrosion products, traces of unseparated plutonium and uranium and most of the transuranic elements, constitutes the high-level waste. At present, these liquid wastes are usually concentrated by evaporation and stored as an aqueous nitric acid solution in high-integrity stainless-steel tanks. There is now world-wide agreement that, for the long term, these liquid wastes should be converted to solid form and much work is in progress to develop techniques for the solidification of these wastes. This paper considers the design requirements for such facilities and the experience gained during nearly 30 years of operation. (orig./RW)

  20. Synthesis, characterization and application of poly(acrylamide-co-methylenbisacrylamide) nanocomposite as a colorimetric chemosensor for visual detection of trace levels of Hg and Pb ions

    Energy Technology Data Exchange (ETDEWEB)

    Sedghi, Roya, E-mail: r_sedghi@sbu.ac.ir; Heidari, Bahareh; Behbahani, Mohammad

    2015-03-21

    Highlights: • Poly(acrylamide-co-methylenbisacrylamide) nanocomposite. • Colorimetric chemosensor. • Determination of trace levels of Hg and Pb ions. • Environmental samples. - Abstract: In this study, a new colorimetric chemosensor based on TiO{sub 2}/poly(acrylamide-co-methylenbisacrylamide) nanocomposites was designed for determination of mercury and lead ions at trace levels in environmental samples. The removal and preconcentration of lead and mercury ions on the sorbent was achieved due to sharing an electron pair of N and O groups of polymer chains with the mentioned heavy metal ions. The hydrogel sensor was designed by surface modification of a synthesized TiO{sub 2} nanoparticles using methacryloxypropyltrimethoxysilan (MAPTMS), which provided a reactive C=C bond that polymerized the acrylamide and methylenbisacrylamide. The sorbent was characterized using X-ray diffraction (XRD), thermogravimetric analysis (TGA), scanning electron microscope (SEM), EDS analysis and Fourier transform in frared (FT-IR) spectrometer. This nanostructured composite with polymer shell was developed as a sensitive and selective sorbent for adsorption of mercury and lead ions from aqueous solution at optimized condition. This method involves two-steps: (1) preconcentration of mercury and lead ions by the synthesized sorbent and (2) its selective monitoring of the target ions by complexation with dithizone (DZ). The color of the sorbent in the absence and presence of mercury and lead ions shifts from white to violet and red, respectively. The detection limit of the synthesized nanochemosensor for mercury and lead ions was 1 and 10 μg L{sup −1}, respectively. The method was successfully applied for trace detection of mercury and lead ions in tap, river, and sea water samples.

  1. Trace analysis

    International Nuclear Information System (INIS)

    Warner, M.

    1987-01-01

    What is the current state of quantitative trace analytical chemistry? What are today's research efforts? And what challenges does the future hold? These are some of the questions addressed at a recent four-day symposium sponsored by the National Bureau of Standards (NBS) entitled Accuracy in Trace Analysis - Accomplishments, Goals, Challenges. The two plenary sessions held on the first day of the symposium reviewed the history of quantitative trace analysis, discussed the present situation from academic and industrial perspectives, and summarized future needs. The remaining three days of the symposium consisted of parallel sessions dealing with the measurement process; quantitation in materials; environmental, clinical, and nutrient analysis; and advances in analytical techniques

  2. Determination of thallium at ultra-trace levels in water and biological samples using solid phase spectrophotometry.

    Science.gov (United States)

    Amin, Alaa S; El-Sharjawy, Abdel-Azeem M; Kassem, Mohammed A

    2013-06-01

    A new simple, very sensitive, selective and accurate procedure for the determination of trace amounts of thallium(III) by solid-phase spectrophotometry (SPS) has been developed. The procedure is based on fixation of Tl(III) as quinalizarin ion associate on a styrene-divinylbenzene anion-exchange resin. The absorbance of resin sorbed Tl(III) ion associate is measured directly at 636 and 830 nm. Thallium(I) was determined by difference measurements after oxidation of Tl(I) to Tl(III) with bromine. Calibration is linear over the range 0.5-12.0 μg L(-1) of Tl(III) with relative standard deviation (RSD) of 1.40% (n=10). The detection and quantification limits are 150 and 495 ng L(-1) using 0.6 g of the exchanger. The molar absorptivity and Sandell sensitivity are also calculated and found to be 1.31×10(7) L mol(-1)cm(-1) and 0.00156 ng cm(-2), respectively. The proposed procedure has been successfully applied to determine thallium in water, urine and serum samples. Copyright © 2013 Elsevier B.V. All rights reserved.

  3. Determination of thallium at ultra-trace levels in water and biological samples using solid phase spectrophotometry

    Science.gov (United States)

    Amin, Alaa S.; El-Sharjawy, Abdel-Azeem M.; Kassem, Mohammed A.

    2013-06-01

    A new simple, very sensitive, selective and accurate procedure for the determination of trace amounts of thallium(III) by solid-phase spectrophotometry (SPS) has been developed. The procedure is based on fixation of Tl(III) as quinalizarin ion associate on a styrene-divinylbenzene anion-exchange resin. The absorbance of resin sorbed Tl(III) ion associate is measured directly at 636 and 830 nm. Thallium(I) was determined by difference measurements after oxidation of Tl(I) to Tl(III) with bromine. Calibration is linear over the range 0.5-12.0 μg L-1 of Tl(III) with relative standard deviation (RSD) of 1.40% (n = 10). The detection and quantification limits are 150 and 495 ng L-1 using 0.6 g of the exchanger. The molar absorptivity and Sandell sensitivity are also calculated and found to be 1.31 × 107 L mol-1 cm-1 and 0.00156 ng cm-2, respectively. The proposed procedure has been successfully applied to determine thallium in water, urine and serum samples.

  4. Simultaneous multi-laser, multi-species trace-level sensing of gas mixtures by rapidly swept continuous-wave cavity-ringdown spectroscopy.

    Science.gov (United States)

    He, Yabai; Kan, Ruifeng; Englich, Florian V; Liu, Wenqing; Orr, Brian J

    2010-09-13

    The greenhouse-gas molecules CO(2), CH(4), and H(2)O are detected in air within a few ms by a novel cavity-ringdown laser-absorption spectroscopy technique using a rapidly swept optical cavity and multi-wavelength coherent radiation from a set of pre-tuned near-infrared diode lasers. The performance of various types of tunable diode laser, on which this technique depends, is evaluated. Our instrument is both sensitive and compact, as needed for reliable environmental monitoring with high absolute accuracy to detect trace concentrations of greenhouse gases in outdoor air.

  5. A High-Voltage Level Tolerant Transistor Circuit

    NARCIS (Netherlands)

    Annema, Anne J.; Geelen, Godefridus Johannes Gertrudis Maria

    2001-01-01

    A high-voltage level tolerant transistor circuit, comprising a plurality of cascoded transistors, including a first transistor (T1) operatively connected to a high-voltage level node (3) and a second transistor (T2) operatively connected to a low-voltage level node (2). The first transistor (T1)

  6. 40 CFR 227.30 - High-level radioactive waste.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 24 2010-07-01 2010-07-01 false High-level radioactive waste. 227.30...-level radioactive waste. High-level radioactive waste means the aqueous waste resulting from the operation of the first cycle solvent extraction system, or equivalent, and the concentrated waste from...

  7. Tracing early evolutionary stages of high-mass star formation with molecular lines

    NARCIS (Netherlands)

    Marseille, M. G.; van der Tak, F. F. S.; Herpin, F.; Jacq, T.

    2010-01-01

    Context. Despite its major role in the evolution of the interstellar medium, the formation of high-mass stars (M >= 10 M(circle dot)) remains poorly understood. Two types of massive star cluster precursors, the so-called massive dense cores (MDCs), have been observed, which differ in terms of their

  8. Origin and tracing techniques of high 15N nitrogen compounds in industrial environments

    International Nuclear Information System (INIS)

    Talma, A.S.; Meyer, R.

    2002-01-01

    Effluents and process waters from various industrial plants were investigated for the 15 N/ 14 N isotope ratio in nitrate and ammonia. It was found that large isotope fractionation occurs in cases where ammonia is involved in gas-liquid phase changes. This feature was found to occur in two coke oven plants where ammonia gas is removed from a gas stream by solution in water, in an ammonia sulphate plant where ammonia gas is absorbed in sulphuric acid and in a water treatment plant where ammonia is removed from (high pH) water by blowing air through the process water. In all these cases 15 N isotope enrichments (in the range of 10 to 30 per mille) occurred. These enrichments are in excess of those found naturally. Ammonia in such wastewaters essentially retains this high 15 N content when it is converted to nitrate underground: which occurs rapidly under well-oxidised conditions. Nitrate is a fairly conservative tracer and its contamination in water can be followed readily. In the low recharge environment in the central parts of South Africa evidence of waste management practices of 10-20 years earlier were still quite evident using this isotopic label. The high 15 N nitrate signal could be used to distinguish industrial nitrogen pollution from pollution by local sewage disposal systems. Vegetation that derives its nitrogen from such high 15 N sources retains the isotope signature of its source. Grass and other annual plants then exhibit the isotope signature of the water of a specific year. Trees exhibit the isotope signature of deeper water, which shows the effects of longer term pollution events. The use of high 15 N as tracer enables the source apportionment of nitrogen derived pollution in these specific circumstances. (author)

  9. Tracing and dealing with dwellings with high radon and radon daughter concentrations

    International Nuclear Information System (INIS)

    Ehdwall, Hans

    1980-01-01

    In the late 1970s it was found that a number of buildings in Sweden, primarily those made from alum shale-based concretes, had elevated radon and radon daughter levels. A special commission investigated the problem and established provisional limiting values for radon daughter exposures, gamma radiation from the ground, and the concentrations of radioactive materials in building materials. With regard to gamma radiation from the ground the commission proposed that no building be built in an area where outside gamma radiation exceeds 100 μR/h. For building materials a gamma index (mγ) and a radium index (mRa) are suggested: mγ = Csub(K)/10000 + Csub(Ra)/1000 + Csub(Th)/700; mRa = Csub(Ra)/200 (Csub(K), Csub(Ra) and Csub(Th) are the concentrations of potassium, radium and thorium respectively). The proposed limiting values are such that the gamma index and the radium index be less than 1. It is also suggested that action should be taken to reduce radon levels in buildings with radon daughter concentrations of 0.27 WL within two years and 0.10 WL within 5 years

  10. Application of mercapto-silica polymerized high internal phase emulsions for the solid-phase extraction and preconcentration of trace lead(II).

    Science.gov (United States)

    Su, Rihui; Ruan, Guihua; Chen, Zhengyi; Du, Fuyou; Li, Jianping

    2015-12-01

    A new class of solid-phase extraction column prepared with grafted mercapto-silica polymerized high internal phase emulsion particles was used for the preconcentration of trace lead. First, mercapto-silica polymerized high internal phase emulsion particles were synthesized by using high internal phase emulsion polymerization and carefully assembled in a polyethylene syringe column. The influences of various parameters including adsorption pH value, adsorption and desorption solvents, flow rate of the adsorption and desorption procedure were optimized, respectively, and the suitable uploading sample volumes, adsorption capacity, and reusability of solid phase extraction column were also investigated. Under the optimum conditions, Pb(2+) could be preconcentrated quantitatively over a wide pH range (2.0-5.0). In the presence of foreign ions, such as Na(+) , K(+) , Ca(2+) , Zn(2+) , Mg(2+) , Cu(2+) , Fe(2+) , Cd(2+) , Cl(-) and NO3 (-) , Pb(2+) could be recovered successfully. The prepared solid-phase extraction column performed with high stability and desirable durability, which allowed more than 100 replicate extractions without measurable changes of performance. The feasibility of the developed method was further validated by the extraction of Pb(2+) in rice samples. At three spiked levels of 40.0, 200 and 800 μg/kg, the average recoveries for Pb(2+) in rice samples ranged from 87.3 to 105.2%. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. Association between level of urinary trace heavy metals and obesity among children aged 6-19 years: NHANES 1999-2011.

    Science.gov (United States)

    Shao, Wentao; Liu, Qian; He, Xiaowei; Liu, Hui; Gu, Aihua; Jiang, Zhaoyan

    2017-04-01

    Global prevalence of obesity has been increasing dramatically in all ages. Although traditional causes for obesity development have been studied widely, it is unclear whether environmental exposure of substances such as trace heavy metals affects obesity development among children and adolescents so far. Data from the National Health and Nutrition Examination Survey (1999-2011) were retrieved, and 6602 US children were analyzed in this study. Urinary level of nine trace heavy metals, including barium, cadmium, cobalt, cesium, molybdenum, lead, antimony, thallium, and tungsten, was analyzed for their association with the prevalence of obesity among children aged 6-19 years. Multiple logistic regression was performed to assess the associations adjusted for age, race/ethnicity, gender, urinary creatinine, PIR, serum cotinine, and television, video game, and computer usage. A remarkable association was found between barium exposure (OR 1.43; 95% CI 1.09-1.88; P obesity in children aged 6-19 years. Negative association was observed between cadmium (OR 0.46; 95% CI 0.33-0.64; P obesity. All the negative associations were stronger in the 6-12 years group than in the 13-19 years group. The present study demonstrated that barium might increase the occurrence of obesity, but cadmium, cobalt, and lead caused weight loss among children. The results imply that trace heavy metals may represent critical risk factors for the development of obesity, especially in the area that the state of metal contamination is serious.

  12. Trace element affinities in two high-Ge coals from China

    Energy Technology Data Exchange (ETDEWEB)

    Jing Li; Xinguo Zhuang; Xavier Querol [China University of Geosciences, Wuhan (China). Faculty of Earth Resources

    2011-01-15

    The Lincang (Yunnan Province, Southwest China) and Wulantuga (Inner Mongolia, Northeast China) coal deposits are known because of the high-Ge content. These coals have also a high concentration of a number of other elements. To determine the mode of occurrence of the enriched elements in both coals, six density fractions from {lt} 1.43 to {gt} 2.8 g/cm{sup 3} were obtained from two representative samples using heavy-liquids. A number of peculiar geochemical patterns characterize these high-Ge coals. Thus, the results of the chemical analysis of these density fractions showed that both coals (very distant and of a different geological age) are highly enriched (compared with the usual worldwide coal concentration ranges) in Ge, As, Sb, W, Be, and Tl. This may be due to similar geochemistry of hydrothermal fluids influencing the Earth Crust in these regions of China. Moreover, Wulantuga coal (Early Cretaceous subbituminous coal) is also enriched in Ca, Mg, and Na, and Lincang coal (Neogene subbituminous coal) in K, Rb, Nb, Mo, Sn, Cs, and U. A group of elements consisting of Ge, W, B, Nb, and Sb mostly occur with an organic affinity in both coals. Additionally, Be, U, and Mo (and partially Mn and Zn) in Lincang, and Na and Mg in Wulantuga occur also with a major organic affinity. Both coals have sulfide-arsenide mineral assemblages (Fe, S, As, Sn, and Pb, and in addition to Tl, Ta, and Cs in the Lincang coal). The occurrence of Al, P, Li, Sc, Ti, V, Cr, and Zr in both coals, and Ba in Lincang, are associated with the mineral assemblage of silico-aluminates and minor heavy minerals. Furthermore, P, Na, Li, Sc, Ti, Ga, Rb, Zr, Cr, Ba, Th, and LREE (La, Ce, Pr, Nd, and Gd) in Lincang are associated with mineral assemblages of phosphates and minor heavy minerals. The two later mineral assemblages are derived from the occurrence of detrital minerals. 34 refs., 7 figs., 3 tabs.

  13. Assessment of the Level of GABA and Some Trace Elements in Blood in Children who Suffer from Familial Febrile Convulsions

    Directory of Open Access Journals (Sweden)

    Osama N. Salah

    2014-03-01

    Full Text Available Febrile seizure is one of the most common neurological problems during childhood. The etiology and pathogenesis of febrile seizure remain unknown. However, several factors such as vitamin B6 deficiency, electrolyte disturbances, and reduction in serum zinc, selenium, magnesium levels, and low gamma - aminobutyric acid (GABA levels are thought to play a role in the pathogenesis of febrile seizure. The present study included twenty children from 10 families, 11 were male and 9 were female. Each family has at least 2 members with a history of febrile convulsion. All cases were subjected to the following: Determination of serum levels of copper, zinc, magnesium, selenium level in serum, and plasma level of γ-aminobytaric acid (GABA. Serum levels of selenium and GABA were statistically significantly low in comparison with controls. Serum copper was statistically significantly higher in cases than controls, while serum zinc showed no significant changes in the cases of febrile convulsion compared with the control group. The mean Zn level in the serum of febrile convulsion was found to be at lower level than in the control group. The serum magnesium was significantly low in cases than controls. The logistic regression model in our study shows that Selenium and Magnesium have protective effects, while Copper has causative effect.

  14. Release of inorganic trace elements from high-temperature gasification of coal

    Energy Technology Data Exchange (ETDEWEB)

    Blaesing, Marc

    2012-05-30

    The development of cleaner, more efficient techniques in next-generation coal power plants is becoming increasingly important, especially regarding to the discussion of the influence of CO{sub 2} emissions on global warming. A promising coal utilisation process is the integrated gasification combined cycle process. The direct use of the raw gas requires gas clean-up to prevent downstream parts of the gasifier from several problems. An increased efficiency and a decreased amount of harmful species can be achieved through hot fuel gas cleaning. This clean-up technique requires a comprehensive knowledge of the release characteristics of inorganic coal constituents. The aim of this thesis was to provide enhanced knowledge of the effect of key process parameters and of the chemical constitution of coal on the release of Na, K, S, and Cl species from high-temperature coal gasification. The experimental setup consisted of atmospheric flow tube furnaces and a pressurised furnace. In-situ analysis of the product gas was carried out using molecular beam mass spectrometry. A broad spectrum of different coals with assumed qualitative and quantitative differences in the release characteristics was investigated. Additionally, experiments with model substances were performed. The results of the experimental investigation were compared with thermodynamic calculations. Finally, recommendations, for the operation of a high-temperature gasifier are formulated. (orig.)

  15. Trace metals analysis of hair samples from students in metropolitan area high school

    International Nuclear Information System (INIS)

    Chiu, S.F.; Wang, P.C.; Kao, P.F.; Chung Shan Medical University, Taichung, Taiwan; Lin, J.B.; Chung Shan Medical University, Taichung, Taiwan; Lin, D.B.; Chen, C.Y.

    2011-01-01

    Hair samples from junior high school students in metropolitan areas of Taichung, Taiwan were tested for a total of 13 elements, Al, Ag, Br, Cl, Cr, Fe, K, La, Mn, Na, Sc, Se, and Zn by instrumental neutron activation analysis (INAA) to establish seasonal variations, gender and environmental exposures. The seasonal variations of hairs in 39 healthy students (18 males and 21 females; age 13.3 ± 0.4 years; height, 158.0 ± 4.1 cm; weight, 53.4 ± 5.7 kg) were collected at 1.5-month intervals for 1 year starting from late August, 2008. The concentrations of the above elements varied from 10 3 to 10 -2 μg g -1 at different sampling times. A quantified index of agreement (AT) was introduced to help classify the elements. A smaller AT indicated highly consistent quantities of specific metals in the hair while a larger AT indicated increased fluctuation, i.e., less agreement. The different ATs in various hair samples were discussed. The concentrations of these elements are compared with the data in the literature. (author)

  16. Evaluation of radionuclide concentrations in high-level radioactive wastes

    International Nuclear Information System (INIS)

    Fehringer, D.J.

    1985-10-01

    This report describes a possible approach for development of a numerical definition of the term ''high-level radioactive waste.'' Five wastes are identified which are recognized as being high-level wastes under current, non-numerical definitions. The constituents of these wastes are examined and the most hazardous component radionuclides are identified. This report suggests that other wastes with similar concentrations of these radionuclides could also be defined as high-level wastes. 15 refs., 9 figs., 4 tabs

  17. Analysis of Cyberbullying Sensitivity Levels of High School Students and Their Perceived Social Support Levels

    Science.gov (United States)

    Akturk, Ahmet Oguz

    2015-01-01

    Purpose: The purpose of this paper is to determine the cyberbullying sensitivity levels of high school students and their perceived social supports levels, and analyze the variables that predict cyberbullying sensitivity. In addition, whether cyberbullying sensitivity levels and social support levels differed according to gender was also…

  18. Mechanisms of formation of trace decomposition products in complex high explosive mixtures

    Energy Technology Data Exchange (ETDEWEB)

    Woodyard, J.D.; Burgess, C.E. [West Texas A and M Univ., Canyon, TX (United States); Rainwater, K.A. [Texas Tech Univ., Lubbock, TX (United States)

    1999-03-01

    A significant concern in the nation`s stockpile surveillance program in prediction of the lifetimes of the high explosives (HE) and their components as the weapons age. The Department of Energy`s Core Surveillance and Enhanced Surveillance programs specifically target issues of degradation of HE, binders, and plastic-bonded explosives (PBX) for determination of component lifetimes and handling procedures. These material science topics are being addressed at the DOE national laboratories and production plants, including Pantex. The principal goal of this project is to identify the mechanisms of decomposition of HE, plasticizers, plastic polymer binders, and radical stabilizers resulting from exposures to ionizing radiation, heat, and humidity. The following reports the work completed for 1998, including a comprehensive literature review about some of the materials examined and the laboratory work completed to date. The materials focused on in the laboratory are TATB, Estane 5301, and Irganox 1010.

  19. Lineage tracing of genome-edited alleles reveals high fidelity axolotl limb regeneration.

    Science.gov (United States)

    Flowers, Grant Parker; Sanor, Lucas D; Crews, Craig M

    2017-09-16

    Salamanders are unparalleled among tetrapods in their ability to regenerate many structures, including entire limbs, and the study of this ability may provide insights into human regenerative therapies. The complex structure of the limb poses challenges to the investigation of the cellular and molecular basis of its regeneration. Using CRISPR/Cas, we genetically labelled unique cell lineages within the developing axolotl embryo and tracked the frequency of each lineage within amputated and fully regenerated limbs. This allowed us, for the first time, to assess the contributions of multiple low frequency cell lineages to the regenerating limb at once. Our comparisons reveal that regenerated limbs are high fidelity replicas of the originals even after repeated amputations.

  20. Application of nuclear activation analysis (NAA) and low-level gamma counting to determine the radionuclide and trace element pollutant releases from coal-fired power plants in Vietnam

    International Nuclear Information System (INIS)

    Vanduong, P.; Thanh, V.T.; Dien, P.Q.; Binh, N.T.

    1995-01-01

    Results are reported of the application of NAA using research reactors TRIGA II in Dalat, Vietnam, and Vienna, Austria (with pyrolysis separation for Hg, Se, and As before irradiation), to determine As, Cd, Cu, Hg, Ni, Co, Pb, Sn and Zn. Low-level gamma counting was used to measure Ra-226, Th-228 and K-40, released from coal-fired power plants in Vietnam. Results showed that: (1) the content of the air pollutants in the vicinity of the operating power plants (in 1991, the Phalai plant produced 1700 million kWh, and the Ninhbinh plant 100 million kWh) depends on the coal combustion which is used for their applied operation technology, both plants used Quangninh anthracite as fuel. The content of trace elements pollutants (TEP) in the environment of the Ninhbinh plant is higher than in the Phalai plant. (2) In the vicinity of both plants, rain water is highly polluted by trace elements such as As, Cu, Pb, Hg, Ni, Co, Cd, Se, U, Th and sulphuric acid. Therefore, this kind of water is not acceptable for human consumption. (3) The algae growing in the waterfield in the vicinity of the power plants can be used to monitor TEP. Four NAA methods, in combination with low-level gamma counting and AAS, can be successfully used to monitor TEP released from power plants

  1. Development of a software system for spatial resolved trace analysis of high performance materials with SIMS

    International Nuclear Information System (INIS)

    Brunner, Ch. H.

    1997-09-01

    . The third publication investigates the influence of non-metallic impurities on the material behavior of high speed steels (HSS). The fourth publication tries to give an insight into the oxidation behavior of high purity molybdenum. (author)

  2. Investigation of trace level binding of PtCl6 and PtCl4 to alfalfa biomass (Medicago sativa) using Zeeman graphite furnace atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Parsons, J.G.; Gardea-Torresdey, J.L.; Tiemann, K.J.; Gamez, G.

    2002-01-01

    Batch laboratory experiments were performed to investigate the effects of pH, chemical modification, time dependency, and interference studies on the binding of trace concentrations of hexachloroplatinate(IV) and tetrachloroplatinate(II) to alfalfa biomass. The pH profiles were measured between pH 2.0 and 6.0. It was found that the binding of trace concentrations of platinum(IV and II) to alfalfa biomass was dependent on pH with a maximum binding occurring at pH 3.0 and a minimum at pH 6.0. When the alfalfa biomass was chemically modified (esterified), maximum binding occurred at pH 6.0 for both oxidation states of platinum. From the batch time dependency experiments, it was found that binding took at least 20 min to level off for both platinum oxidation states. Batch experiments were performed with various concentrations of calcium, magnesium, and sodium (0.1, 1.0, 10, 100 and 1000 ppm) and it was found that calcium affected the binding of platinum(II and IV) to the alfalfa biomass. It was determined that magnesium and sodium did not interfere appreciably with the binding of platinum in either of the oxidation states studied. Finally, batch experiments were performed with Mg 2+ , Ca 2+ and Na + in solutions at various concentrations, and it was observed that the binding was affected similarly to that by calcium alone

  3. Lithium titanate hybridized with trace amount of graphene used as an anode for a high rate lithium ion battery

    International Nuclear Information System (INIS)

    Dong, Hai-Yong; He, Yan-Bing; Li, Baohua; Zhang, Chen; Liu, Ming; Su, Fangyuan; Lv, Wei; Kang, Feiyu; Yang, Quan-Hong

    2014-01-01

    A novel Li 4 Ti 5 O 12 (LTO) electrode with a hierarchical carbon-based conducting network has been developed for high rate lithium ion battery. The unique network is constructed by graphene sheets (GS) that are not only dispersed among (inter-) but also inside (intra-) LTO particles, together with a thin carbon layer wrapping around the LTO particles. The intraparticle GS promotes the electron transfer inside LTO particles while the interparticle GS together with carbon coating bridges the particles guaranteeing fast electron transfer among LTO particles, which construct a highway throughout the whole electrode sheet. Quantitatively, only a trace amount of GS (∼ 0.4 wt%) synergistic with carbon coating (∼0.8 wt%) contributes to a more effective conducting network in the produced LTO electrode and as a result much better performance as compared to the LTO case with similar carbon coating but free of GS. Due to the effectiveness of the conducting network, even with a tap density as high as ∼1.0 g cm −3 , the novel LTO possesses both excellent rate performance and cycling behaviors. The capacity of 123.5 mA h g −1 is obtained at a charge/discharge rate as high as 30 C and a very high capacity of 144.8 mAh g −1 is maintained even after 100 cycles at 10 C. Due to such a low fraction of carbon and a high tape density, the novel LTO electrode has a great practical application value in both the power and energy storage lithium ion batteries

  4. Trace level liquid chromatography tandem mass spectrometry quantification of the mutagenic impurity 2-hydroxypyridine N-oxide as its dansyl derivative.

    Science.gov (United States)

    Ding, Wei; Huang, Yande; Miller, Scott A; Bolgar, Mark S

    2015-03-20

    A derivatization LC-MS/MS method was developed and qualified for the trace level quantification of 2-hydroxypyridine N-oxide (HOPO). HOPO is a coupling reagent used in the syntheses of active pharmaceutical ingredients (APIs) to form amide bonds. HOPO was recently confirmed to generate a positive response in a GLP Ames bacterial-reverse-mutation test, classifying it as a mutagenic impurity and as such requiring its control in APIs to the threshold of toxicological concern (TTC). The derivatization reagent 5-dimethylamino-1-naphthalenesulfonyl chloride (dansyl chloride) was used in a basic solution to convert HOPO into the corresponding dansyl-derivative. The derivative was separated from different APIs and reagents by liquid chromatography. The detection of the HOPO dansyl-derivative was achieved by mass spectrometry in selected reaction monitoring (SRM) mode. The LC-MS/MS method had a reporting limit of 0.1ng/mL HOPO, which corresponds to 0.1ppm HOPO relative to an API at 1mg/mL, and a linearity range of 0.1-25ng/mL HOPO analyte. Recoveries of HOPO standards spiked into three different API matrices at 0.2, 1.2, and 20ppm levels were all within 90-100%. An SRM-based confirmatory methodology using the ratios of two fragment ions at three CID energies was developed to verify the identity of HOPO when present at ≥0.6ppm. This identity confirmation can be employed to prevent potential false positive detection of mutagenic impurities at trace level. It can be broadly applicable for the confirmation of analytes when the analytes generate at least two major fragments in tandem mass spectrometry experiments. Copyright © 2015 Elsevier B.V. All rights reserved.

  5. Magnesium and trace metals: risk factors for coronary heart disease - associations between blood levels and angiographic findings

    International Nuclear Information System (INIS)

    Manthey, J.; Stoeppler, M.; Morgenstern, W.; Nussel, E.; Opherk, D.; Weintraut, A.; Wesch, H.; Kubler, W.

    1981-01-01

    A deficiency or an excessive intake of metals with cardiovascular effects is suspected to be involved in the pathogenesis of coronary heart disease (CHD) and sudden death. Therefore, in 106 patients undergoing coronary arteriography, serum levels of six essential metals (magnesium, chromium, copper, manganese, selenium and zinc) and whole blood concentrations of two elements without known essential function (cadmium and lead) were measured using atomic absorption spectrophotometry, including the flameless technique, or neutron activation analysis. Our results suggest that a deficiency of magnesium but not of the other metals studied may be present in patients with severe CHD; elevated serum copper and manganese levels do not play a role in the development of CHD in the sample of patients studied; and cigarette smoking may be associated with increased serum cadmium levels, which may explain in part the contribution of smoking to the risk of sudden death in patients with CHD

  6. Discovery of high-level tasks in the operating room

    NARCIS (Netherlands)

    Bouarfa, L.; Jonker, P.P.; Dankelman, J.

    2010-01-01

    Recognizing and understanding surgical high-level tasks from sensor readings is important for surgical workflow analysis. Surgical high-level task recognition is also a challenging task in ubiquitous computing because of the inherent uncertainty of sensor data and the complexity of the operating

  7. Characteristics of solidified high-level waste products

    International Nuclear Information System (INIS)

    1979-01-01

    The object of the report is to contribute to the establishment of a data bank for future preparation of codes of practice and standards for the management of high-level wastes. The work currently in progress on measuring the properties of solidified high-level wastes is being studied

  8. Process for solidifying high-level nuclear waste

    Science.gov (United States)

    Ross, Wayne A.

    1978-01-01

    The addition of a small amount of reducing agent to a mixture of a high-level radioactive waste calcine and glass frit before the mixture is melted will produce a more homogeneous glass which is leach-resistant and suitable for long-term storage of high-level radioactive waste products.

  9. The Influence of Decreased Levels of High Density Lipoprotein ...

    African Journals Online (AJOL)

    Background: Changes in lipoproteins levels in sickle cell disease (SCD) patients are well.known, but the physiological ramifications of the low levels observed have not been entirely resolved. Aim: The aim of this study is to evaluate the impact of decreased levels of high density lipoprotein cholesterol (HDL.c) on ...

  10. The ATLAS High-Level Calorimeter Trigger in Run-2

    CERN Document Server

    Wiglesworth, Craig; The ATLAS collaboration

    2018-01-01

    The ATLAS Experiment uses a two-level triggering system to identify and record collision events containing a wide variety of physics signatures. It reduces the event rate from the bunch-crossing rate of 40 MHz to an average recording rate of 1 kHz, whilst maintaining high efficiency for interesting collision events. It is composed of an initial hardware-based level-1 trigger followed by a software-based high-level trigger. A central component of the high-level trigger is the calorimeter trigger. This is responsible for processing data from the electromagnetic and hadronic calorimeters in order to identify electrons, photons, taus, jets and missing transverse energy. In this talk I will present the performance of the high-level calorimeter trigger in Run-2, noting the improvements that have been made in response to the challenges of operating at high luminosity.

  11. Trace element partitioning between ilmenite, armalcolite and anhydrous silicate melt: Implications for the formation of lunar high-Ti mare basalts

    NARCIS (Netherlands)

    Kan Parker, M. van; Mason, P.R.D.; Westrenen, W. van

    2011-01-01

    We performed a series of experiments at high pressures and temperatures to determine the partitioning of a wide range of trace elements between ilmenite (Ilm), armalcolite (Arm) and anhydrous lunar silicate melt, to constrain geochemical models of the formation of titanium-rich melts in the Moon.

  12. Note: Possibilities of detecting the trace-level erosion products from an electric propulsion hollow cathode plasma source by the method of time-of-flight mass spectrometry

    Science.gov (United States)

    Ning, Zhong-Xi; Zhang, Hai-Guang; Zhu, Xi-Ming; Jiang, Bin-Hao; Zhou, Zhong-Yue; Yu, Da-Ren; An, Bing-Jian; Wang, Yan-Fei

    2018-02-01

    A hollow cathode produces electrons which neutralize ions from electric propulsion thrusters. After hundreds to thousands of hours of operation in space, the cathode materials can be significantly eroded due to ion bombardment. As a result, the electric propulsion system performance will be obviously changed or even fail. In this work, the erosion products from a LaB6 hollow cathode (widely used presently in electric propulsion systems) are studied by using a specific detection system, which consists of a molecular beam sampler and a time-of-flight mass spectrometer. This system measures trace-level-concentration (10-6-10-3) products. Boron (B), tantalum (Ta), and tungsten (W)—originating from the emitter, keeper, and orifice of the hollow cathode—are measured. It is found that the erosion rate is significantly influenced by the gas flow rate to the cathode.

  13. Silver ion modulated CdS quantum dots for highly selective detection of trace Hg{sup 2+}

    Energy Technology Data Exchange (ETDEWEB)

    Uppa, Yuwapon; Kulchat, Sirinan; Ngamdee, Kessarin; Pradublai, Kaewklao [Materials Chemistry Research Unit, Department of Chemistry and Center of Excellence for Innovation in Chemistry, Faculty of Science, Khon Kaen University, Khon Kaen 40002 (Thailand); Tuntulani, Thawatchai [Department of Chemistry, Faculty of Science, Chulalongkorn University, Bangkok 10330 (Thailand); Ngeontae, Wittaya, E-mail: wittayange@kku.ac.th [Materials Chemistry Research Unit, Department of Chemistry and Center of Excellence for Innovation in Chemistry, Faculty of Science, Khon Kaen University, Khon Kaen 40002 (Thailand); Research Center for Environmental and Hazardous Substance Management, Khon Kaen University, Khon Kaen 40002 (Thailand); Center of Excellence for Environmental and Hazardous Waste Management (EHWM), Bangkok 10330 (Thailand)

    2016-10-15

    In the present work, water-soluble cysteamine capped-CdS quantum dots (Cys-CdS QDs) modulated with Ag{sup +} were employed as fluorescence sensors for the determination of Hg{sup 2+} ion. The synthesized Cys-CdS QDs exhibit relatively weak fluorescence emission, however, the emission was enhanced exclusively in the presence of Ag{sup +} compared to other metal ions. Moreover, the fluorescence intensity of the Ag{sup +} modulated Cys-CdS QDs (Ag{sup +}@Cys-CdS QDs) was significantly quenched in the presence of trace amounts of Hg{sup 2+} due to high-affinity metallophilic interactions between Hg{sup 2+} and Ag{sup +}. Based on this specific interaction, good selectivity towards the detection of Hg{sup 2+} over other metal ions was achieved. To gain the best sensing performance, parameters affecting the Hg{sup 2+} detection sensitivity were studied and optimized in detail. Under the optimized conditions, the fluorescence intensity of Ag{sup +}@Cys-CdS QDs decreased linearly with Hg{sup 2+} concentration in the range of 0.1–3.5 μM, with a limit of detection of around 0.09 μM. The applicability of this sensor was demonstrated by the determination of Hg{sup 2+} in drinking water samples, corresponding well with results of cold-vapor atomic absorption spectrometry.

  14. Determination of trace concentrations of chlorine in aqueous solutions by high-resolution continuum source graphite furnace molecular absorption spectrometry

    Science.gov (United States)

    Machyňák, Ľubomír; Čacho, František; Němeček, Martin; Beinrohr, Ernest

    2016-11-01

    Trace concentrations of total chlorine were determined by means of molecular absorption of indium mono-chloride (InCl) at 267.217 nm using high-resolution continuum source graphite furnace molecular absorption spectrometry. The effects of chemical modifiers and the amount of In on the sensitivity and accuracy were investigated. The optimum pyrolysis and vaporization temperatures were 600 °C and 1400 °C, respectively. The limit of detection and characteristic mass were found to be 0.10 ng and 0.21 ng, respectively. Potential non-spectral and spectral interferences were tested for various metals and non-metals at concentrations up to 50 mg L- 1 and for phosphoric, sulphuric and nitric acids. No spectral interferences were observed. Significant non-spectral interferences were observed with F, Br, and I at concentrations higher than 1 mg L- 1, 5 mg L- 1 and 25 mg L- 1, respectively, which is probably caused by formation of competitive indium halogen molecules. Higher concentrations of mineral acids depressed the signal owing to the formation of volatile HCl. The calibration curve was linear in the range between 0.3 and 10 ng with a correlation coefficient of R = 0.993. The elaborated method was used for the chlorine determination in various waters and a drug sample.

  15. Application of spectrophotometry for determination of analytes in high percentage levels

    International Nuclear Information System (INIS)

    Koteswara Rao, M.; Ram Mohan, Vijaya; Yadav, R.B.

    2009-01-01

    This paper describes the application of differential Spectrophotometry for the determination of analytes in high concentration levels unlike the conventional photometric methods that are useful for measuring concentration at trace levels. Differential spectrophotometry is based on measuring the absorbance of the test solution against a standard of accurately known concentration instead of a reagent blank or pure solvent. In this way, the error in measurement is confined to the difference in the two concentrations and is minimized. Thus the error is much smaller than in conventional Spectrophotometry, which therefore allows its application for determining analytes in major concentration. This method was applied for the assay of Niobium and Titanium used as strategic materials in various field. (author)

  16. A new method for the homogeneous precipitative separation of trace level lanthanides as oxalates: application to different types of geological samples

    International Nuclear Information System (INIS)

    Premadas, A.; Cyriac, Bincy; Kesavan, V.S.

    2013-01-01

    Oxalate precipitation of lanthanides in acidic medium is a widely used selective group separation method at percentage to trace level in different types of geological samples. Most of the procedures are based on the heterogeneous oxalate precipitation of lanthanides using calcium as carrier. In the heterogeneous precipitation, the co-precipitated impurities from the matrix elements are more, besides if the pH at the time of precipitation is not monitored carefully there is a chance of losing some of the lanthanides. In this report, we present a new homogeneous oxalate precipitation of trace level lanthanides from different types of geological samples using calcium as carrier. In the present method pH is getting adjusted (pH ∼1) on its own, after the hydrolysis of urea added to the sample solution. This acidic pH is essential for the complete precipitation of the lanthanides. Therefore, no critical parameter adjustment for the precipitation is involved in the proposed method. The oxalate precipitate obtained was in crystalline nature which facilitates the fast settlement, easy filtration; besides the co-precipitated matrix elements are very less as compared to normal heterogeneous oxalate precipitation of lanthanides. Another advantage is more quantity of the sample can be taken for the separation of lanthanides which is a limitation for other separation methods reported. Accuracy of the method was checked by analyzing nine international reference materials comprising different types of geological samples obtained from Canadian Certified Reference Project Materials such as syenite samples SY-2, SY-3 and SY-4; gabro sample MRG-1; soil samples SO-1 and SO-2; iron formation sample FeR-2; lake sediments LKSD-2 and LKSD-4. The values of the lanthanides obtained for these reference materials are comparable with recommended values, indicating that the method is accurate. The reproducibility is characterized by a relative standard deviation (RSD) of 1 to 6% (n=4). (author)

  17. Predictors of Placement in Lower Level versus Higher Level High School Mathematics

    Science.gov (United States)

    Archbald, Doug; Farley-Ripple, Elizabeth N.

    2012-01-01

    Educators and researchers have long been interested in determinants of access to honors level and college prep courses in high school. Factors influencing access to upper level mathematics courses are particularly important because of the hierarchical and sequential nature of this subject and because students who finish high school with only lower…

  18. Stable superconducting magnet. [high current levels below critical temperature

    Science.gov (United States)

    Boom, R. W. (Inventor)

    1967-01-01

    Operation of a superconducting magnet is considered. A method is described for; (1) obtaining a relatively high current in a superconducting magnet positioned in a bath of a gas refrigerant; (2) operating a superconducting magnet at a relatively high current level without training; and (3) operating a superconducting magnet containing a plurality of turns of a niobium zirconium wire at a relatively high current level without training.

  19. Direct detection of benzene, toluene, and ethylbenzene at trace levels in ambient air by atmospheric pressure chemical ionization using a handheld mass spectrometer.

    Science.gov (United States)

    Huang, Guangming; Gao, Liang; Duncan, Jason; Harper, Jason D; Sanders, Nathaniel L; Ouyang, Zheng; Cooks, R Graham

    2010-01-01

    The capabilities of a portable mass spectrometer for real-time monitoring of trace levels of benzene, toluene, and ethylbenzene in air are illustrated. An atmospheric pressure interface was built to implement atmospheric pressure chemical ionization for direct analysis of gas-phase samples on a previously described miniature mass spectrometer (Gao et al. Anal. Chem.2006, 78, 5994-6002). Linear dynamic ranges, limits of detection and other analytical figures of merit were evaluated: for benzene, a limit of detection of 0.2 parts-per-billion was achieved for air samples without any sample preconcentration. The corresponding limits of detection for toluene and ethylbenzene were 0.5 parts-per-billion and 0.7 parts-per-billion, respectively. These detection limits are well below the compounds' permissible exposure levels, even in the presence of added complex mixtures of organics at levels exceeding the parts-per-million level. The linear dynamic ranges of benzene, toluene, and ethylbenzene are limited to approximately two orders of magnitude by saturation of the detection electronics. 2010 American Society for Mass Spectrometry. Published by Elsevier Inc. All rights reserved.

  20. Levels, fluxes and time trends of persistent organic pollutants in Lake Thun, Switzerland: Combining trace analysis and multimedia modeling

    International Nuclear Information System (INIS)

    Bogdal, Christian; Scheringer, Martin; Schmid, Peter; Blaeuenstein, Markus; Kohler, Martin; Hungerbuehler, Konrad

    2010-01-01

    Levels, mass fluxes, and time trends of polybrominated diphenyl ethers (PBDEs) and polychlorinated biphenyls (PCBs) in Lake Thun, a peri-Alpine lake, are investigated. We present measurements of PBDEs and PCBs in air, lake water, lake sediment, and tributary water. These measurements are combined with a multimedia fate model, based on site-specific environmental parameters from the lake catchment. Measured loadings of PBDEs and PCBs in air and tributaries were used to drive the model. The model satisfactorily reproduces PBDE and PCB congener patterns in water and sediment, but it tends to yield concentrations in water below the measurements and concentrations in sediment exceeding the measurements. A sensitivity analysis reveals that partitioning of PBDEs and PCBs between the aqueous dissolved phase and suspended particulate matter in the water column strongly affects the model results, in particular the concentrations in water and sediment. For lower-brominated PBDEs, approximately 70% and 30% of input into the lake stems from atmospheric deposition and from tributaries, respectively. For heavier PBDEs and all PCBs, rivers appear to deliver the major load (64-92%). Waste water effluents are of minor importance. 50-90% of the total input is buried in the permanent sediment. Sediment burial makes PBDEs and PCBs less available for recycling in the environment, and reduces concentrations in the outflowing river. If use of deca-BDE increases in the future, levels in Lake Thun will follow the same trend. If the use and resulting environmental emissions decrease, concentrations in water will rapidly decline, according to our calculations, while sediment levels will decrease at a considerably slower rate.

  1. Vegetation and Cold Trapping Modulating Elevation-dependent Distribution of Trace Metals in Soils of a High Mountain in Eastern Tibetan Plateau.

    Science.gov (United States)

    Bing, Haijian; Wu, Yanhong; Zhou, Jun; Li, Rui; Luo, Ji; Yu, Dong

    2016-04-07

    Trace metals adsorbed onto fine particles can be transported long distances and ultimately deposited in Polar Regions via the cold condensation effect. This study indicated the possible sources of silver (Ag), cadmium (Cd), copper (Cu), lead (Pb), antimony (Sb) and zinc (Zn) in soils on the eastern slope of Mt. Gongga, eastern Tibetan Plateau, and deciphered the effects of vegetation and mountain cold condensation on their distributions with elevation. The metal concentrations in the soils were comparable to other mountains worldwide except the remarkably high concentrations of Cd. Trace metals with high enrichment in the soils were influenced from anthropogenic contributions. Spatially, the concentrations of Cu and Zn in the surface horizons decreased from 2000 to 3700 m a.s.l., and then increased with elevation, whereas other metals were notably enriched in the mid-elevation area (approximately 3000 m a.s.l.). After normalization for soil organic carbon, high concentrations of Cd, Pb, Sb and Zn were observed above the timberline. Our results indicated the importance of vegetation in trace metal accumulation in an alpine ecosystem and highlighted the mountain cold trapping effect on trace metal deposition sourced from long-range atmospheric transport.

  2. Practical experience in and improvements to aerosol sampling for trace analysis of airborne radionuclides in ground level air

    International Nuclear Information System (INIS)

    Arnold, D.; Jagielak, J.; Kolb, W.; Pietruszewski, A.; Wershofen, H.; Zarucki, R.

    1994-01-01

    In November 1989 the Polish government and the German government signed a bilateral agreement for scientific and technological co-operation. In the framework of this co-operation the Central Laboratory for Radiological Protection (CLRP), Warsaw, and the Physikalisch-Technische Bundesanstalt (PTB), Braunschweig, conducted a co-operation project in the field of monitoring the airborne radioactivity in ground level air. This progress report deals with the history of the project covering the period from July 1990 to December 1992, the scientific activities and their results. A proposal for future co-operation, which is planned for the near future, is made. (orig.)

  3. A binderless, covalently bulk modified electrochemical sensor: Application to simultaneous determination of lead and cadmium at trace level

    Energy Technology Data Exchange (ETDEWEB)

    Gunigollahalli Kempegowda, Raghu [Department of Studies in Chemistry, Bangalore University, Central College Campus, Bangalore 560001 (India); Malingappa, Pandurangappa, E-mail: mprangachem@gmail.com [Department of Studies in Chemistry, Bangalore University, Central College Campus, Bangalore 560001 (India)

    2012-05-30

    Highlights: Black-Right-Pointing-Pointer Proposed sensor is a new type of binderless covalent bulk modified electrode. Black-Right-Pointing-Pointer Surface can be easily renewed by simple mechanical polishing using emery sheets. Black-Right-Pointing-Pointer Free from modifier leaching during electrochemical measurements. Black-Right-Pointing-Pointer Provides long term storage stability with good reproducibility. Black-Right-Pointing-Pointer Nanomolar level detection limit achieved with selectivity. - Abstract: A new type of covalent binderless bulk modified electrode has been fabricated and used in the simultaneous determination of lead and cadmium ions at nanomolar level. The modification of graphitic carbon with 4-amino salicylic acid was carried out under microwave irradiation through the amide bond formation. The electrochemical behavior of the fabricated electrode has been carried out to decipher the interacting ability of the functional moieties present on the modifier molecules toward the simultaneous determination of Pb{sup 2+} and Cd{sup 2+} ions using cyclic and differential pulse anodic stripping voltammetry. The possible mode of interaction of functional groups with metal ions is proposed based on the pKa values of the modifier functionalities present on the surface of graphitic carbon particles. The analytical utility of the proposed sensor has been validated by measuring the lead and cadmium content from pretreated waste water samples of lead acid batteries.

  4. Vitamin, Trace Element, and Fatty Acid Levels of Vitex agnus-castus L., Juniperus oxycedrus L., and Papaver somniferum L. Plant Seeds

    Directory of Open Access Journals (Sweden)

    Ahmet Ozkaya

    2013-01-01

    Full Text Available The levels of fat-soluble vitamin, trace element and fatty acid of Vitex agnus-castus L., Juniperus oxycedrus L., and Papaver somniferum L. seeds in Turkey were determined by using HPLC, ICP-OES, and GC, respectively. In the Vitex agnus-castus L., Juniperus oxycedrus L., and Papaver somniferum L. seeds, linoleic acid (18 : 2 was determined with the highest level rates (%54.11, %28.03, and %72.14, resp.. In the Vitex agnus-castus L. seeds, R-tocopherol, α-tocopherol, and K1 levels were determined as 9.70 μg/g, 18.20 μg/g, and 24.79 μg/g, respectively; In the Juniperus oxycedrus L. seeds, R-tocopherol, α-tocopherol, and K1 were determined as 18.50 μg/g, 0.84 μg/g, and 5.00 μg/g, respectively, and in the Papaver somniferum L. seeds, R-tocopherol, α-tocopherol, K1, and D2 levels were determined as 43.25 μg/g, 122.05 μg/g, 12.01 μg/g, and 0.62 μg/g, respectively. In the Vitex agnus-castus L., Juniperus oxycedrus L., and Papaver somniferum L. seeds, nickel (Ni, zinc (Zn, and iron (Fe were determined with the trace element level rates (4.42 mg/kg, 10.43 mg/kg, 3.71 mg/kg for Ni, 7.00 mg/kg, 7.70 mg/kg, and 24 mg/kg for Zn and 93.73 mg/kg, 187.95 mg/kg, and 149.64 mg/kg for Fe, resp.. These parameters in seeds are very important for human life.

  5. Experimental study of trace metal chemistry in soft-water lakes at different pH levels

    Energy Technology Data Exchange (ETDEWEB)

    Jackson, T A; Kipphut, G; Hesslein, R H; Schindler, D W

    1980-03-01

    The biogeochemistry of Hg, Zn, Co, Fe, Mn, Cr, V, Th, Ba, Cs, As, and Se in two soft-water lakes of the Canadian shield was investigated. The residence times of the radionuclides in the water were determined, and the partitioning of the nuclides among different metal-binding agents in the water and sediments was studied. Metals of high crystal field stabilization energy, high electronegativity, or small ionic radius were most readily scavenged by greater than 0.45 micrometer suspended particles and dispersed colloids in the water, disappeared most rapidly from the water column, and were preferentially accumulated by sedimentary binding agents, including organic substances. Hg was removed fairly rapidly from the water at pH 6.7-6.8 owing to its high electronegativity but was removed more slowly than any other metal at pH 5.1 owing to its large ionic radius. Acidification of lake water to pH 5.1 interfered with accumulation of Hg and other metals by organic ooze. Acidification also lowered the concentration of extractable colloidal phosphate in the ooze but had no effect on extractable orthophosphate content. 45 references, 10 figures, 4 tables.

  6. Ultrasensitive, real-time trace gas detection using a high-power, multimode diode laser and cavity ringdown spectroscopy.

    Science.gov (United States)

    Karpf, Andreas; Qiao, Yuhao; Rao, Gottipaty N

    2016-06-01

    We present a simplified cavity ringdown (CRD) trace gas detection technique that is insensitive to vibration, and capable of extremely sensitive, real-time absorption measurements. A high-power, multimode Fabry-Perot (FP) diode laser with a broad wavelength range (Δλlaser∼0.6  nm) is used to excite a large number of cavity modes, thereby reducing the detector's susceptibility to vibration and making it well suited for field deployment. When detecting molecular species with broad absorption features (Δλabsorption≫Δλlaser), the laser's broad linewidth removes the need for precision wavelength stabilization. The laser's power and broad linewidth allow the use of on-axis cavity alignment, improving the signal-to-noise ratio while maintaining its vibration insensitivity. The use of an FP diode laser has the added advantages of being inexpensive, compact, and insensitive to vibration. The technique was demonstrated using a 1.1 W (λ=400  nm) diode laser to measure low concentrations of nitrogen dioxide (NO2) in zero air. A sensitivity of 38 parts in 1012 (ppt) was achieved using an integration time of 128 ms; for single-shot detection, 530 ppt sensitivity was demonstrated with a measurement time of 60 μs, which opens the door to sensitive measurements with extremely high temporal resolution; to the best of our knowledge, these are the highest speed measurements of NO2 concentration using CRD spectroscopy. The reduced susceptibility to vibration was demonstrated by introducing small vibrations into the apparatus and observing that there was no measurable effect on the sensitivity of detection.

  7. High-level waste immobilization program: an overview

    International Nuclear Information System (INIS)

    Bonner, W.R.

    1979-09-01

    The High-Level Waste Immobilization Program is providing technology to allow safe, affordable immobilization and disposal of nuclear waste. Waste forms and processes are being developed on a schedule consistent with national needs for immobilization of high-level wastes stored at Savannah River, Hanford, Idaho National Engineering Laboratory, and West Valley, New York. This technology is directly applicable to high-level wastes from potential reprocessing of spent nuclear fuel. The program is removing one more obstacle previously seen as a potential restriction on the use and further development of nuclear power, and is thus meeting a critical technological need within the national objective of energy independence

  8. National high-level waste systems analysis report

    Energy Technology Data Exchange (ETDEWEB)

    Kristofferson, K.; Oholleran, T.P.; Powell, R.H.

    1995-09-01

    This report documents the assessment of budgetary impacts, constraints, and repository availability on the storage and treatment of high-level waste and on both existing and pending negotiated milestones. The impacts of the availabilities of various treatment systems on schedule and throughput at four Department of Energy sites are compared to repository readiness in order to determine the prudent application of resources. The information modeled for each of these sites is integrated with a single national model. The report suggests a high-level-waste model that offers a national perspective on all high-level waste treatment and storage systems managed by the Department of Energy.

  9. National high-level waste systems analysis report

    International Nuclear Information System (INIS)

    Kristofferson, K.; Oholleran, T.P.; Powell, R.H.

    1995-09-01

    This report documents the assessment of budgetary impacts, constraints, and repository availability on the storage and treatment of high-level waste and on both existing and pending negotiated milestones. The impacts of the availabilities of various treatment systems on schedule and throughput at four Department of Energy sites are compared to repository readiness in order to determine the prudent application of resources. The information modeled for each of these sites is integrated with a single national model. The report suggests a high-level-waste model that offers a national perspective on all high-level waste treatment and storage systems managed by the Department of Energy

  10. The ATLAS high level trigger region of interest builder

    International Nuclear Information System (INIS)

    Blair, R.; Dawson, J.; Drake, G.; Haberichter, W.; Schlereth, J.; Zhang, J.; Ermoline, Y.; Pope, B.; Aboline, M.; High Energy Physics; Michigan State Univ.

    2008-01-01

    This article describes the design, testing and production of the ATLAS Region of Interest Builder (RoIB). This device acts as an interface between the Level 1 trigger and the high level trigger (HLT) farm for the ATLAS LHC detector. It distributes all of the Level 1 data for a subset of events to a small number of (16 or less) individual commodity processors. These processors in turn provide this information to the HLT. This allows the HLT to use the Level 1 information to narrow data requests to areas of the detector where Level 1 has identified interesting objects

  11. Levels of trace elements, methylmercury and polybrominated diphenyl ethers in foraging green turtles in the South China region and their conservation implications.

    Science.gov (United States)

    Ng, Connie Ka Yan; Lam, James Chung Wah; Zhang, Xiao Hua; Gu, He Xiang; Li, Tsung Hsien; Ye, Min Bin; Xia, Zhong Rong; Zhang, Fei Yan; Duan, Jin Xia; Wang, Wen Xiong; Lam, Isaac Kam Sum; Balazs, George H; Lam, Paul K S; Murphy, Margaret B

    2018-03-01

    Sea turtles are globally endangered and face daily anthropogenic threats, including pollution. However, there is a lack of ecotoxicological information on sea turtles, especially in the Asia-Pacific region. This study aims to determine pollutant levels of foraging green turtles (Chelonia mydas) in South China, including Hong Kong, Guangdong and Taiwan, as a basis for their conservation. Scute, liver and muscle tissues of stranded green turtles were analysed for levels of 17 trace elements and methylmercury (MeHg) (n = 86 for scute and n = 14 for liver) and polybrominated diphenyl ethers (PBDEs) (n = 11 for muscle and n = 13 for liver). Ten-fold higher levels of Pb, Ba, V and Tl and 40-fold greater Cd levels were measured in green turtle livers in South China relative to other studies conducted over 10 years ago. Measured PBDE levels were also 27-fold and 50-fold greater than those reported in Australia and Japan. These results warrant further investigation of potential toxicological risks to green turtles in South China and their source rookeries in Malaysia, Micronesia, Indonesia, Marshall Islands, Japan and Taiwan. Research should target monitoring pollutant levels in sea turtles within the West Pacific/Southeast Asia regional management unit spanning East Asia to Southeast Asia to fill in knowledge gaps, in particular in areas such as Thailand, Vietnam, Indonesia, Malaysia and the Philippines where less or no data is available and where foraging grounds of sea turtles have been identified. Copyright © 2017 Elsevier Ltd. All rights reserved.

  12. Safety assessment of street vended juices in Multan-Pakistan: A study on prevalence levels of trace elements

    Directory of Open Access Journals (Sweden)

    Saeed Akhtar

    2015-08-01

    Full Text Available Street vended juices are most commonly available, accessible and economical nutritional food sources of poor slums in developing economies like Pakistan. Study was undertaken to elucidate impact of industrialization, agro chemicals induction in agronomic practices and food processing hygiene measurements on food chain heavy metals intoxication. If overlooked, certain quality risks associated either with fresh produce or processed commodity might initiate food intoxication.In order to understand gravity of the issue, street vended freshly drawn juices extracted from the food crops (orange, sugarcane, carrot and mango cultivated in Southern Punjab peri-urban areas and country sides were evaluated for microelements and heavy metals load in summer and winter 2012. The safety study of juices depicted higher concentration of lead (Pb and cadmium (Cd breaching international safety limits implemented in the country. However some microelements (Fe, Zn, Mn were found below the prescribed maximum tolerant limits. The study concluded prevalence of higher concentration of some toxic heavy metals as a serious breach of threshold levels potentially compromising consumer’s safety.

  13. Safety assessment of street vended juices in Multan-Pakistan: A study on prevalence levels of trace elements

    Directory of Open Access Journals (Sweden)

    Saeed Akhtar

    2015-07-01

    Full Text Available Street vended juices are most commonly available, accessible and economical nutritional food sources of poor slums in developing economies like Pakistan. Study was undertaken to elucidate impact of industrialization, agro chemicals induction in agronomic practices and food processing hygiene measurements on food chain heavy metals intoxication. If overlooked, certain quality risks associated either with fresh produce or processed commodity might initiate food intoxication.In order to understand gravity of the issue, street vended freshly drawn juices extracted from the food crops (orange, sugarcane, carrot and mango cultivated in Southern Punjab peri-urban areas and country sides were evaluated for microelements and heavy metals load in summer and winter 2012. The safety study of juices depicted higher concentration of lead (Pb and cadmium (Cd breaching international safety limits implemented in the country. However some microelements (Fe, Zn, Mn were found below the prescribed maximum tolerant limits. The study concluded prevalence of higher concentration of some toxic heavy metals as a serious breach of threshold levels potentially compromising consumer’s safety.

  14. Measurement of 239Pu in urine samples at ultra-trace levels using a 1 MV compact AMS system

    International Nuclear Information System (INIS)

    Hernandez-Mendoza, H.; Chamizo, E.; Yllera, A.; Garcia-Leon, M.; Delgado, A.

    2010-01-01

    Routine bioassay monitoring of Pu intake in exposed workers of research and nuclear industry is usually performed by alpha spectrometry. This technique involves large sample volumes of urine and time-consuming preparative and counting protocols. Compact accelerator mass spectrometry (AMS) facilities make feasible the determination of ultra low-level Pu activity concentrations and Pu isotopic ratios in biological samples (blood, urine and feces), being a rapid and cost-effective measurement technique. The plutonium results in urine samples presented here have been obtained on the 1 MV compact AMS system sited at the Centro Nacional de Aceleradores (CNA), in Seville, Spain. In this work, a different methodological approach has been developed alternative to the 'classical' preparation of urine samples for alpha spectrometry. The procedure avoids the Pu precipitation step, and involves acid sample evaporation and acid digestion in a microwave oven. Finally, purification of plutonium was achieved by using chromatography columns filled up with BioRad AG1X2 anion exchange resin (Bio-Rad Laboratories Inc.). The total time needed for analysis is about 10 h, unlike the 'classical' methods based on alpha spectrometry which need about 1 week. At present, it has been demonstrated that this method allows quantifying 239 Pu activity concentrations in urine of, at least, 30 μBq (13 fg 239 Pu). We can conclude that the procedure would be suitable to perform in vitro routine bioassay measurements. Moreover, the innovative application of AMS opens new and interesting analytical alternatives in this field.

  15. Electric discharge for treatment of trace contaminants

    Science.gov (United States)

    Flamm, D. L.; Wydeven, T. J. (Inventor)

    1978-01-01

    A radio frequency glow discharge reactor is described for removing trace oxidizable contaminants from an oxygen bearing atmosphere. The reaction chamber is defined by an inner metal electrode facing a dielectric backed by an outer conductive electrode. In one embodiment, a conductive liquid forms the conductor of an outer electrode and cools the dielectric. A resonator coupled to a variable radio frequency source generates the high voltages for creating a glow discharge in the chamber at a predetermined pressure whereby the trace contaminants are oxidized into a few simple non-toxic products that may be easily recovered. The corresponding process for removal of trace contaminants from an oxygen-bearing atmosphere with high efficiency independent of the concentration level is also disclosed.

  16. Handling and storage of conditioned high-level wastes

    International Nuclear Information System (INIS)

    1983-01-01

    This report deals with certain aspects of the management of one of the most important wastes, i.e. the handling and storage of conditioned (immobilized and packaged) high-level waste from the reprocessing of spent nuclear fuel and, although much of the material presented here is based on information concerning high-level waste from reprocessing LWR fuel, the principles, as well as many of the details involved, are applicable to all fuel types. The report provides illustrative background material on the arising and characteristics of high-level wastes and, qualitatively, their requirements for conditioning. The report introduces the principles important in conditioned high-level waste storage and describes the types of equipment and facilities, used or studied, for handling and storage of such waste. Finally, it discusses the safety and economic aspects that are considered in the design and operation of handling and storage facilities

  17. NOS CO-OPS Water Level Data, Verified, High Low

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This dataset has verified (quality-controlled), daily, high low water level (tide) data from NOAA NOS Center for Operational Oceanographic Products and Services...

  18. Artificial Heads for High-Level Impulse Sound Measurement

    National Research Council Canada - National Science Library

    Buck, K

    1999-01-01

    If the Insertion Loss (IL) of hearing protectors has to be determined with very high impulse or continuous noise levels, the acoustic insulation of the Artificial Test Fixture has to exceed at least the Insertion Loss (IL...

  19. Technical career opportunities in high-level radioactive waste management

    International Nuclear Information System (INIS)

    1993-01-01

    Technical career opportunities in high-level radioactive waste management are briefly described in the areas of: Hydrology; geology; biological sciences; mathematics; engineering; heavy equipment operation; and skilled labor and crafts

  20. Long-term high-level waste technology program

    International Nuclear Information System (INIS)

    1980-04-01

    The Department of Energy (DOE) is conducting a comprehensive program to isolate all US nuclear wastes from the human environment. The DOE Office of Nuclear Energy - Waste (NEW) has full responsibility for managing the high-level wastes resulting from defense activities and additional responsiblity for providing the technology to manage existing commercial high-level wastes and any that may be generated in one of several alternative fuel cycles. Responsibilities of the Three Divisions of DOE-NEW are shown. This strategy document presents the research and development plan of the Division of Waste Products for long-term immobilization of the high-level radioactive wastes resulting from chemical processing of nuclear reactor fuels and targets. These high-level wastes contain more than 99% of the residual radionuclides produced in the fuels and targets during reactor operations. They include essentially all the fission products and most of the actinides that were not recovered for use

  1. Glasses used for the high level radioactive wastes storage

    International Nuclear Information System (INIS)

    Sombret, C.

    1983-06-01

    High level radioactive wastes generated by the reprocessing of spent fuels is an important concern in the conditioning of radioactive wastes. This paper deals with the status of the knowledge about glasses used for the treatment of these liquids [fr

  2. Handling and storage of conditioned high-level wastes

    International Nuclear Information System (INIS)

    Heafield, W.

    1984-01-01

    This paper deals with certain aspects of the management of one of the most important radioactive wastes arising from the nuclear fuel cycle, i.e. the handling and storage of conditioned high-level wastes. The paper is based on an IAEA report of the same title published during 1983 in the Technical Reports Series. The paper provides illustrative background material on the characteristics of high-level wastes and, qualitatively, their requirements for conditioning. The principles important in the storage of high-level wastes are reviewed in conjunction with the radiological and socio-political considerations involved. Four fundamentally different storage concepts are described with reference to published information and the safety aspects of particular storage concepts are discussed. Finally, overall conclusions are presented which confirm the availability of technology for constructing and operating conditioned high-level waste storage facilities for periods of at least several decades. (author)

  3. Development of melt compositions for sulphate bearing high level waste

    International Nuclear Information System (INIS)

    Jahagirdar, P.B.; Wattal, P.K.

    1997-09-01

    The report deals with the development and characterization of vitreous matrices for sulphate bearing high level waste. Studies were conducted in sodium borosilicate and lead borosilicate systems with the introduction of CaO, BaO, MgO etc. Lead borosilicate system was found to be compatible with sulphate bearing high level wastes. Detailed product evaluation carried on selected formulations is also described. (author)

  4. Properties and characteristics of high-level waste glass

    International Nuclear Information System (INIS)

    Ross, W.A.

    1977-01-01

    This paper has briefly reviewed many of the characteristics and properties of high-level waste glasses. From this review, it can be noted that glass has many desirable properties for solidification of high-level wastes. The most important of these include: (1) its low leach rate; (2) the ability to tolerate large changes in waste composition; (3) the tolerance of anticipated storage temperatures; (4) its low surface area even after thermal shock or impact

  5. High-Level Waste System Process Interface Description

    International Nuclear Information System (INIS)

    D'Entremont, P.D.

    1999-01-01

    The High-Level Waste System is a set of six different processes interconnected by pipelines. These processes function as one large treatment plant that receives, stores, and treats high-level wastes from various generators at SRS and converts them into forms suitable for final disposal. The three major forms are borosilicate glass, which will be eventually disposed of in a Federal Repository, Saltstone to be buried on site, and treated water effluent that is released to the environment

  6. How healthy is urban horticulture in high traffic areas? Trace metal concentrations in vegetable crops from plantings within inner city neighbourhoods in Berlin, Germany

    International Nuclear Information System (INIS)

    Säumel, Ina; Kotsyuk, Iryna; Hölscher, Marie; Lenkereit, Claudia; Weber, Frauke; Kowarik, Ingo

    2012-01-01

    Food production by urban dwellers is of growing importance in developing and developed countries. Urban horticulture is associated with health risks as crops in urban settings are generally exposed to higher levels of pollutants than those in rural areas. We determined the concentration of trace metals in the biomass of different horticultural crops grown in the inner city of Berlin, Germany, and analysed how the local setting shaped the concentration patterns. We revealed significant differences in trace metal concentrations depending on local traffic, crop species, planting style and building structures, but not on vegetable type. Higher overall traffic burden increased trace metal content in the biomass. The presence of buildings and large masses of vegetation as barriers between crops and roads reduced trace metal content in the biomass. Based on this we discuss consequences for urban horticulture, risk assessment, and planting and monitoring guidelines for cultivation and consumption of crops. - Highlights: ► Traffic-related pollutant deposition as important pathway for crop contamination. ► Heavy metal content often over EU standards for lead concentration in food crops. ► ‘Grow your own’ food in inner cities not always ‘healthier’ than supermarket products. ► No support for generalisations of crops as ‘risky high’ or ‘safe low’ accumulators. - Higher overall traffic burden increased, while the presence of buildings and large masses of vegetation as barriers between crops and roads reduced heavy metal content in crop biomass.

  7. High level waste canister emplacement and retrieval concepts study

    International Nuclear Information System (INIS)

    1975-09-01

    Several concepts are described for the interim (20 to 30 years) storage of canisters containing high level waste, cladding waste, and intermediate level-TRU wastes. It includes requirements, ground rules and assumptions for the entire storage pilot plant. Concepts are generally evaluated and the most promising are selected for additional work. Follow-on recommendations are made

  8. Adsorption characteristics of trace levels of bromate in drinking water by modified bamboo-based activated carbons.

    Science.gov (United States)

    Chen, Ho-Wen; Chuang, Yen Hsun; Hsu, Cheng-Feng; Huang, Winn-Jung

    2017-09-19

    This study was undertaken to investigate the adsorption kinetics and isotherms of bromate (BrO 3 - ) on bamboo charcoals that are activated with nitrogen and water vapor. Bamboo-based activated carbon (AC) was dipped in acid and oxidized in a mixture of potassium permanganate and sulfuric acid. Oxidation treatment considerably improved the physicochemical properties of AC, including purity, pore structure and surface nature, significantly enhancing BrO 3 - adsorption capacity. AC with many oxygenated groups and a high mesopore volume exhibited a particularly favorable tendency for BrO 3 - adsorption. Its adsorption of BrO 3 - is best fitted using Langmuir isotherm, and forms a monolayer. A kinetic investigation revealed that the adsorption of BrO 3 - by the ACs involved chemical sorption and was controlled by intra-particle diffusion. The competitive effects of natural organic matter (NOM) on AC were evaluated, and found to reduce the capacity of carbon to adsorb BrO 3 - . Residual dissolved ozone reacted with AC, reducing its capacity to absorb BrO 3 - . Proper dosing and staging of the ozonation processes can balance the ozone treatment efficiency, BrO 3 - formation, and the subsequent removal of BrO 3 - .

  9. Arbuscular mycorrhizal fungal inoculation protects Miscanthus × giganteus against trace element toxicity in a highly metal-contaminated site.

    Science.gov (United States)

    Firmin, Stéphane; Labidi, Sonia; Fontaine, Joël; Laruelle, Frédéric; Tisserant, Benoit; Nsanganwimana, Florian; Pourrut, Bertrand; Dalpé, Yolande; Grandmougin, Anne; Douay, Francis; Shirali, Pirouz; Verdin, Anthony; Lounès-Hadj Sahraoui, Anissa

    2015-09-15

    Arbuscular mycorrhizal fungus (AMF)-assisted phytoremediation could constitute an ecological and economic method in polluted soil rehabilitation programs. The aim of this work was to characterize the trace element (TE) phytoremediation potential of mycorrhizal Miscanthus × giganteus. To understand the mechanisms involved in arbuscular mycorrhizal symbiosis tolerance to TE toxicity, the fatty acid compositions and several stress oxidative biomarkers were compared in the roots and leaves of Miscanthus × giganteus cultivated under field conditions in either TE-contaminated or control soils. TEs were accumulated in greater amounts in roots, but the leaves were the organ most affected by TE contamination and were characterized by a strong decrease in fatty acid contents. TE-induced oxidative stress in leaves was confirmed by an increase in the lipid peroxidation biomarker malondialdehyde (MDA). TE contamination decreased the GSSG/GSH ratio in the leaves of exposed plants, while peroxidase (PO) and superoxide dismutase (SOD) activities were increased in leaves and in whole plants, respectively. AMF inoculation also increased root colonization in the presence of TE contamination. The mycorrhizal colonization determined a decrease in SOD activity in the whole plant and PO activities in leaves and induced a significant increase in the fatty acid content in leaves and a decrease in MDA formation in whole plants. These results suggested that mycorrhization is able to confer protection against oxidative stress induced by soil pollution. Our findings suggest that mycorrhizal inoculation could be used as a bioaugmentation technique, facilitating Miscanthus cultivation on highly TE-contaminated soil. Copyright © 2015. Published by Elsevier B.V.

  10. INAA for the determination of trace elements and evaluation of their enrichment factors in lichens of high altitude areas

    International Nuclear Information System (INIS)

    Bergamaschi, L.; Rizzio, E.; Giaveri, G.; Profumo, A.; Gallorini, M.; Giordani, L.

    2005-01-01

    Trace element (TE) characterization and analysis in epiphytic lichens collected in different areas of the Himalayas (Nepal) and of the Alps (Italy) is presented. The results give information for the assessment of TE distribution present in the two different areas. The evaluation of the enrichment factors may provide information for many elements about their association to long-distance atmospheric transport phenomena. To this purpose, samples of superficial soils, collected in the same areas of those of the lichens, have also been analyzed. Most of the trace elements were determined by instrumental neutron activation analysis (INAA), while lead and cadmium measurements were carried out with electrothermal atomic absorption spectroscopy (ET-AAS). (author)

  11. Elevated level of polysaccharides in a high level UV-B tolerant cell ...

    African Journals Online (AJOL)

    Jane

    2011-04-26

    Apr 26, 2011 ... A cell line of Bupleurum scorzonerifolium Willd with high level ... mechanisms to repair UV-induced damages via repairing ... for treatment or prevention of solar radiation. ..... working as both UV-B absorbing compounds and.

  12. High level of CA 125 due to large endometrioma.

    Science.gov (United States)

    Phupong, Vorapong; Chen, Orawan; Ultchaswadi, Pornthip

    2004-09-01

    CA 125 is a tumor-associated antigen. Its high levels are usually associated with ovarian malignancies, whereas smaller increases in the levels were associated with benign gynecologic conditions. The authors report a high level of CA 125 in a case of large ovarian endometrioma. A 45-year-old nulliparous Thai woman, presented with an increase of her abdominal girth for 7 months. Transabdominal ultrasonogram demonstrated a large ovarian cyst and multiple small leiomyoma uteri, and serum CA 125 level was 1,006 U/ml. The preoperative diagnosis was ovarian cancer with leiomyoma uteri. Exploratory laparotomy was performed. There were a large right ovarian endometrioma, small left ovarian endometrioma and multiple small leiomyoma. Total abdominal hysterectomy and bilateral salpingo-oophorectomy was performed and histopathology confirmed the diagnosis of endometrioma and leiomyoma. The serum CA 125 level declined to non-detectable at the 4th week. She was well at discharge and throughout her 4th week follow-up period Although a very high level of CA 125 is associated with a malignant process, it can also be found in benign conditions such as a large endometrioma. The case emphasizes the association of high levels of CA 125 with benign gynecologic conditions.

  13. Temporal variability of the quality of Taraxacum officinale seed progeny from the East-Ural radioactive trace: is there an interaction between low level radiation and weather conditions?

    Science.gov (United States)

    Pozolotina, Vera N; Antonova, Elena V

    2017-03-01

    The multiple stressors, in different combinations, may impact differently upon seed quality, and low-level doses of radiation may enhance synergistic or antagonistic effects. During 1991-2014 we investigated the quality of the dandelion (Taraxacum officinale s.l.) seed progeny growing under low-level radiation exposure at the East-Ural Radioactive Trace (EURT) area (result of the Kyshtym accident, Russia), and in plants from areas exposed to background radiation. The viability of the dandelion seed progeny was assessed according to chronic radiation exposure, accounting for the variability of weather conditions among years. Environmental factors (temperature, precipitation, and their ratio in different months) can modify the radiobiological effects. We found a wide range of possible responses to multiple stressors: inhibition, stimulation, and indifferent effects in different seasons. The intraspecific variability of the quality of dandelion seed progeny was greatly increased under conditions of low doses of chronic irradiation. Temperature was the most significant factor for seed progeny formation in the EURT zone, whereas the sums of precipitation and ratios of precipitation to temperature dominantly affected organisms from the background population.

  14. Treatment of High-Level Waste Arising from Pyrochemical Processes

    International Nuclear Information System (INIS)

    Lizin, A.A.; Kormilitsyn, M.V.; Osipenko, A.G.; Tomilin, S.V.; Lavrinovich, Yu.G.

    2013-01-01

    JSC “SSC RIAR” has been performing research and development activities in support of closed fuel cycle of fast reactor since the middle of 1960s. Fuel cycle involves fabrication and reprocessing of spent nuclear fuel (SNF) using pyrochemical methods of reprocessing in molten alkali metal chlorides. At present pyrochemical methods of SNF reprocessing in molten chlorides has reached such a level in their development that makes it possible to compare their competitiveness with classic aqueous methods. Their comparative advantage lies in high safety, compactness, high protectability as to nonproliferation of nuclear materials, and reduction of high level waste volume

  15. High-level trigger system for the LHC ALICE experiment

    CERN Document Server

    Bramm, R; Lien, J A; Lindenstruth, V; Loizides, C; Röhrich, D; Skaali, B; Steinbeck, T M; Stock, Reinhard; Ullaland, K; Vestbø, A S; Wiebalck, A

    2003-01-01

    The central detectors of the ALICE experiment at LHC will produce a data size of up to 75 MB/event at an event rate less than approximately equals 200 Hz resulting in a data rate of similar to 15 GB/s. Online processing of the data is necessary in order to select interesting (sub)events ("High Level Trigger"), or to compress data efficiently by modeling techniques. Processing this data requires a massive parallel computing system (High Level Trigger System). The system will consist of a farm of clustered SMP-nodes based on off- the-shelf PCs connected with a high bandwidth low latency network.

  16. Comparative Study of Trace Metrics between Bibliometrics and Patentometrics

    Directory of Open Access Journals (Sweden)

    Fred Y. Ye

    2016-06-01

    Full Text Available Purpose: To comprehensively evaluate the overall performance of a group or an individual in both bibliometrics and patentometrics. Design/methodology/approach: Trace metrics were applied to the top 30 universities in the 2014 Academic Ranking of World Universities (ARWU — computer sciences, the top 30 ESI highly cited papers in the computer sciences field in 2014, as well as the top 30 assignees and the top 30 most cited patents in the National Bureau of Economic Research (NBER computer hardware and software category. Findings: We found that, by applying trace metrics, the research or marketing impact efficiency, at both group and individual levels, was clearly observed. Furthermore, trace metrics were more sensitive to the different publication-citation distributions than the average citation and h-index were. Research limitations: Trace metrics considered publications with zero citations as negative contributions. One should clarify how he/she evaluates a zero-citation paper or patent before applying trace metrics. Practical implications: Decision makers could regularly examinine the performance of their university/company by applying trace metrics and adjust their policies accordingly. Originality/value: Trace metrics could be applied both in bibliometrics and patentometrics and provide a comprehensive view. Moreover, the high sensitivity and unique impact efficiency view provided by trace metrics can facilitate decision makers in examining and adjusting their policies.

  17. Upgrade of long trace profiler for characterization of high-precision X-ray mirrors at SPring-8

    International Nuclear Information System (INIS)

    Senba, Y.; Kishimoto, H.; Ohashi, H.; Yumoto, H.; Zeschke, T.; Siewert, F.; Goto, S.; Ishikawa, T.

    2010-01-01

    The long trace profiler (LTP) at SPring-8 has been upgraded to improve stability and resolution of slope measurement. The performances of the upgraded LTP at SPring-8 are presented by cross-checking measurements on a flat mirror with data obtained using Nanometer Optical Component Measuring Machine (NOM) at the Helmholtz Zentrum Berlin/BESSY-II.

  18. Variation along the year of trace metal levels in the compartments of the seagrass Posidonia oceanica in Port El Kantaoui, Tunisia.

    Science.gov (United States)

    Zakhama-Sraieb, Rym; Sghaier, Yassine Ramzi; Hmida, Ahmed Ben; Cappai, Giovanna; Carucci, Alessandra; Charfi-Cheikhrouha, Faouzia

    2016-01-01

    The accumulation of the five trace metals (TMs) cadmium, copper, lead, nickel and zinc was measured in Posidonia oceanica leaves. Shoots were seasonally sampled at 8-10-m depth from four stations located in Port El Kantaoui area, Tunisia, during four campaigns performed in 2012. Levels of the five TMs were analyzed using inductively coupled plasma atomic emission spectrometry (ICP-AES) in three compartments of P. oceanica shoots: blades and sheaths of adult leaves and intermediate leaves. Results showed a preferential accumulation of Cd, Pb, Ni and Zn in adult leaf blades. Therefore, we focus on the study of this compartment. TM levels of blades of adult leaves decreased in the following order: Zn > Ni > Cu > Pb > Cd, irrespective of the season. Levels of the five TMs significantly differed between seasons (p < 0.01). Levels of Cd and Cu showed a seasonal pattern: Cd decreased from spring to winter while Cu increased during that same period of time. A significant correlation (p < 0.01) was found between Cd-Cu and Cd-Pb. A significant correlation (p < 0.05) was also noted between Cd-Ni in the adult leaf blades. A relationship was recorded between the foliar surface of the adult leaf blades and Zn accumulation. This survey allowed to highlight the annual variation of TM accumulation in adult leaf blades of P. oceanica, in relation with ecophysiology of this seagrass. Therefore, this study reinforces the usefulness and the relevance of this compartment of P. oceanica, easy to sample without destruction of whole shoot, as a bioindicator of Zn, Ni, Cd and Pb contamination.

  19. Implementation trial of high performance trace analysis/environmental sampling (HPTA/ES) in uranium centrifuge enrichment plants

    International Nuclear Information System (INIS)

    Nackaerts, H.; Kloeckner, W.; Landresse, G.; MacLean, F.; Betti, M.; Forcina, V.; Hiernaut, T.; Tamborini, G.; Koch, L.; Schenkel, R.

    1999-01-01

    Field trials have demonstrated that the analysis of particles upon swipes obtained from inside nuclear installations provides clear signatures of past operations in that installation. This can offer a valuable tool for gaining assurance regarding the compliance with declared activities and the absence of undeclared activities (e.g. enrichment, reprocessing, and reactor operation) at such sites. This method, known as 'Environmental Sampling' (ES) or 'High Performance Trace Analysis' (HPTA) in EURATOM terminology, is at present being evaluated by the EURATOM Safeguards Directorate (ESD) in order to assess its possible use in nuclear installations within the European Union. It is expected that incorporation of HPTA/ES of sample collection and analysis into routine inspection activities will allow EURATOM to improve the effectiveness of safeguards in these installations and hopefully save inspection resources as well. The EURATOM Safeguards Directorate has therefore performed implementation trials involving the collection of particles by the so-called swipe sampling method in uranium centrifuge enrichment plants and hot cells in the European Union. These samples were subsequently analysed by the Joint Research Centre, Institute for Transuranium Elements (ITU) in Karlsruhe. Sampling points were chosen on the basis of the activities performed in the vicinity and by considering the possible ways through which particles are released, diffused and transported. The aim was to test the efficiency of the method as regards: the collection of enough representative material; the identification of a large enough number of uranium particles; the accurate measurement of the enrichment of the uranium particles found on the swipe; the representativity of the results in respect of past activities in the plant; the capability of detecting whether highly enriched uranium has been produced, used or occasionally transported in a location where low enriched uranium is routinely produced in

  20. Background levels of some major, trace, and rare earth elements in indigenous plant species growing in Norway and the influence of soil acidification, soil parent material, and seasonal variation on these levels.

    Science.gov (United States)

    Gjengedal, Elin; Martinsen, Thomas; Steinnes, Eiliv

    2015-06-01

    Baseline levels of 43 elements, including major, trace, and rare earth elements (REEs) in several native plant species growing in boreal and alpine areas, are presented. Focus is placed on species metal levels at different soil conditions, temporal variations in plant tissue metal concentrations, and interspecies variation in metal concentrations. Vegetation samples were collected at Sogndal, a pristine site in western Norway, and at Risdalsheia, an acidified site in southernmost Norway. Metal concentrations in the different species sampled in western Norway are compared with relevant literature data from Norway, Finland, and northwest Russia, assumed to represent natural conditions. Except for aluminium (Al) and macronutrients, the levels of metals were generally lower in western Norway than in southern Norway and may be considered close to natural background levels. In southern Norway, the levels of cadmium (Cd) and lead (Pb) in particular appear to be affected by air pollution, either by direct atmospheric supply or through soil acidification. Levels of some elements show considerable variability between as well as within plant species. Calcium (Ca), magnesium (Mg), and potassium (K) are higher in most species at Sogndal compared to Risdalsheia, despite increased extractable concentrations in surface soil in the south, probably attributed to different buffer mechanisms in surface soil. Antagonism on plant uptake is suggested between Ca, Mg, and K on one hand and Al on the other. Tolerance among calcifuges to acid conditions and a particular ability to detoxify or avoid uptake of Al ions are noticeable for Vaccinium vitis-idaea.

  1. Overview: Defense high-level waste technology program

    International Nuclear Information System (INIS)

    Shupe, M.W.; Turner, D.A.

    1987-01-01

    Defense high-level waste generated by atomic energy defense activities is stored on an interim basis at three U.S. Department of Energy (DOE) operating locations; the Savannah River Plant in South Carolina, the Hanford Site in Washington, and the Idaho National Engineering Laboratory in Idaho. Responsibility for the permanent disposal of this waste resides with DOE's Office of Defense Waste and Transportation Management. The objective of the Defense High-Level Wast Technology Program is to develop the technology for ending interim storage and achieving permanent disposal of all U.S. defense high-level waste. New and readily retrievable high-level waste are immobilized for disposal in a geologic repository. Other high-level waste will be stabilized in-place if, after completion of the National Environmental Policy Act (NEPA) process, it is determined, on a site-specific basis, that this option is safe, cost effective and environmentally sound. The immediate program focus is on implementing the waste disposal strategy selected in compliance with the NEPA process at Savannah River, while continuing progress toward development of final waste disposal strategies at Hanford and Idaho. This paper presents an overview of the technology development program which supports these waste management activities and an assessment of the impact that recent and anticipated legal and institutional developments are expected to have on the program

  2. Chromosome Aberration on High Level Background Natural Radiation Areas

    International Nuclear Information System (INIS)

    Yanti-Lusiyanti; Zubaidah-Alatas

    2001-01-01

    When the body is irradiated, all cells can suffer cytogenetic damage that can be seen as structural damage of chromosome in the lymphocytes. People no matter where they live in world are exposed to background radiation from natural sources both internal and external such as cosmic radiation, terrestrial radiation, cosmogenic radiation radon and thoron. Level of area natural ionizing radiation is varies depending on the altitude, the soil or rock conditions, particular food chains and the building materials and construction features. Level of normal areas of background exposure is annual effective dose 2.4 mSv and the high level areas of background exposure 20 mSv. This paper discuses the frequency of aberration chromosome especially dysenteries in several countries having high level radiation background. It seems that frequency of chromosome aberrations increase, generally with the increase of age of the people and the accumulated dose received. (author)

  3. Trace conditioning in insects-keep the trace!

    Science.gov (United States)

    Dylla, Kristina V; Galili, Dana S; Szyszka, Paul; Lüdke, Alja

    2013-01-01

    Trace conditioning is a form of associative learning that can be induced by presenting a conditioned stimulus (CS) and an unconditioned stimulus (US) following each other, but separated by a temporal gap. This gap distinguishes trace conditioning from classical delay conditioning, where the CS and US overlap. To bridge the temporal gap between both stimuli and to form an association between CS and US in trace conditioning, the brain must keep a neural representation of the CS after its termination-a stimulus trace. Behavioral and physiological studies on trace and delay conditioning revealed similarities between the two forms of learning, like similar memory decay and similar odor identity perception in invertebrates. On the other hand differences were reported also, like the requirement of distinct brain structures in vertebrates or disparities in molecular mechanisms in both vertebrates and invertebrates. For example, in commonly used vertebrate conditioning paradigms the hippocampus is necessary for trace but not for delay conditioning, and Drosophila delay conditioning requires the Rutabaga adenylyl cyclase (Rut-AC), which is dispensable in trace conditioning. It is still unknown how the brain encodes CS traces and how they are associated with a US in trace conditioning. Insects serve as powerful models to address the mechanisms underlying trace conditioning, due to their simple brain anatomy, behavioral accessibility and established methods of genetic interference. In this review we summarize the recent progress in insect trace conditioning on the behavioral and physiological level and emphasize similarities and differences compared to delay conditioning. Moreover, we examine proposed molecular and computational models and reassess different experimental approaches used for trace conditioning.

  4. Trace conditioning in insects – Keep the trace!

    Directory of Open Access Journals (Sweden)

    Kristina V Dylla

    2013-08-01

    Full Text Available Trace conditioning is a form of associative learning that can be induced by presenting a conditioned stimulus (CS and an unconditioned stimulus (US following each other, but separated by a temporal gap. This gap distinguishes trace conditioning from classical delay conditioning, where the CS and US overlap. To bridge the temporal gap between both stimuli and to form an association between CS and US in trace conditioning, the brain must keep a neural representation of the CS after its termination – a stimulus trace. Behavioral and physiological studies on trace and delay conditioning revealed similarities between the two forms of learning, like similar memory decay and similar odor identity perception in invertebrates. On the other hand differences were reported also, like the requirement of distinct brain structures in vertebrates or disparities in molecular mechanisms in both vertebrates and invertebrates. For example, in commonly used vertebrate conditioning paradigms the hippocampus is necessary for trace but not for delay conditioning, and Drosophila delay conditioning requires the Rutabaga adenylyl cyclase, which is dispensable in trace conditioning. It is still unknown how the brain encodes CS traces and how they are associated with a US in trace conditioning. Insects serve as powerful models to address the mechanisms underlying trace conditioning, due to their simple brain anatomy, behavioral accessibility and established methods of genetic interference. In this review we summarize the recent progress in insect trace conditioning on the behavioral and physiological level and emphasize similarities and differences compared to delay conditioning. Moreover, we examine proposed molecular and computational models and reassess different experimental approaches used for trace conditioning.

  5. The Ring of Five follows the traces

    International Nuclear Information System (INIS)

    Anon.

    2015-01-01

    The Ring of Five is an informal network of European experts in radioactivity detection belonging to public bodies such as the IRSN. After having evoked different cases of detection (detection of unusual traces of iodine 131 in the region of Stockholm in 2015, detection of high levels of traces of caesium 137 in Switzerland in 1968) which leaded to the identification of the origin of these traces, this article briefly recalls the history of the creation of this network which extended with the occurrence of the Chernobyl accident, describes how the information is transmitted, the use of modelling tools, and outlines that the detection of some species can be associated either to a nuclear accident or to an atmospheric nuclear bomb test, and indicates how new sensors, not sensitive to humidity, have been developed after a lack of detection of iodine 131. In a brief interview, the future of the Ring of Five, topics to be studied and current projects are briefly evoked

  6. Tracing Clues

    DEFF Research Database (Denmark)

    Feldt, Liv Egholm

    The past is all messiness and blurred relations. However, we tend to sort the messiness out through rigorous analytical studies leaving the messiness behind. Carlo Ginzburgs´ article Clues. Roots of an Evidential Paradigm from 1986 invigorates methodological elements of (historical) research, which...... central methodological elements will be further elaborated and discussed through a historical case study that traces how networks of philanthropic concepts and practices influenced the Danish welfare state in the period from the Danish constitution of 1849 until today. The overall aim of this paper...

  7. Managing the nation's commercial high-level radioactive waste

    International Nuclear Information System (INIS)

    1985-03-01

    This report presents the findings and conclusions of OTA's analysis of Federal policy for the management of commercial high-level radioactive waste. It represents a major update and expansion of the Analysis presented to Congress in our summary report, Managing Commercial High-Level Radioactive Waste, published in April of 1982 (NWPA). This new report is intended to contribute to the implementation of NWPA, and in particular to Congressional review of three major documents that DOE will submit to the 99th Congress: a Mission Plan for the waste management program; a monitored retrievable storage (MRS) proposal; and a report on mechanisms for financing and managing the waste program. The assessment was originally focused on the ocean disposal of nuclear waste. OTA later broadened the study to include all aspects of high-level waste disposal. The major findings of the original analysis were published in OTA's 1982 summary report

  8. Techniques for the solidification of high-level wastes

    International Nuclear Information System (INIS)

    1977-01-01

    The problem of the long-term management of the high-level wastes from the reprocessing of irradiated nuclear fuel is receiving world-wide attention. While the majority of the waste solutions from the reprocessing of commercial fuels are currently being stored in stainless-steel tanks, increasing effort is being devoted to developing technology for the conversion of these wastes into solids. A number of full-scale solidification facilities are expected to come into operation in the next decade. The object of this report is to survey and compare all the work currently in progress on the techniques available for the solidification of high-level wastes. It will examine the high-level liquid wastes arising from the various processes currently under development or in operation, the advantages and disadvantages of each process for different types and quantities of waste solutions, the stages of development, the scale-up potential and flexibility of the processes

  9. Spent fuel and high-level radioactive waste storage

    International Nuclear Information System (INIS)

    Trigerman, S.

    1988-06-01

    The subject of spent fuel and high-level radioactive waste storage, is bibliographically reviewed. The review shows that in the majority of the countries, spent fuels and high-level radioactive wastes are planned to be stored for tens of years. Sites for final disposal of high-level radioactive wastes have not yet been found. A first final disposal facility is expected to come into operation in the United States of America by the year 2010. Other final disposal facilities are expected to come into operation in Germany, Sweden, Switzerland and Japan by the year 2020. Meanwhile , stress is placed upon the 'dry storage' method which is carried out successfully in a number of countries (Britain and France). In the United States of America spent fuels are stored in water pools while the 'dry storage' method is still being investigated. (Author)

  10. Production and properties of solidified high-level waste

    International Nuclear Information System (INIS)

    Brodersen, K.

    1980-08-01

    Available information on production and properties of solidified high-level waste are presented. The review includes literature up to the end of 1979. The feasibility of production of various types of solidified high-level wast is investigated. The main emphasis is on borosilicate glass but other options are also mentioned. The expected long-term behaviour of the materials are discussed on the basis of available results from laboratory experiments. Examples of the use of the information in safety analysis of disposal in salt formations are given. The work has been made on behalf of the Danish utilities investigation of the possibilities of disposal of high-level waste in salt domes in Jutland. (author)

  11. Translation of a High-Level Temporal Model into Lower Level Models: Impact of Modelling at Different Description Levels

    DEFF Research Database (Denmark)

    Kraft, Peter; Sørensen, Jens Otto

    2001-01-01

    given types of properties, and examine how descriptions on higher levels translate into descriptions on lower levels. Our example looks at temporal properties where the information is concerned with the existence in time. In a high level temporal model with information kept in a three-dimensional space...... the existences in time can be mapped precisely and consistently securing a consistent handling of the temporal properties. We translate the high level temporal model into an entity-relationship model, with the information in a two-dimensional graph, and finally we look at the translations into relational...... and other textual models. We also consider the aptness of models that include procedural mechanisms such as active and object databases...

  12. Research on high level radioactive waste repository seismic design criteria

    International Nuclear Information System (INIS)

    Jing Xu

    2012-01-01

    Review seismic hazard analysis principle and method in site suitable assessment process of Yucca Mountain Project, and seismic design criteria and seismic design basis in primary design process. Demonstrated spatial character of seismic hazard by calculated regional seismic hazard map. Contrasted different level seismic design basis to show their differences and relation. Discussed seismic design criteria for preclosure phrase of high level waste repository and preference goal under beyond design basis ground motion. (author)

  13. Validation of an extraction paper chromatography (EPC) technique for estimation of trace levels of 90Sr in 90Y solutions obtained from 90Sr/90Y generator systems

    International Nuclear Information System (INIS)

    Usha Pandey; Yogendra Kumar; Ashutosh Dash

    2014-01-01

    While the extraction paper chromatography (EPC) technique constitutes a novel paradigm for the determination of few Becquerels of 90 Sr in MBq quantities of 90 Y obtained from 90 Sr/ 90 Y generator, validation of the technique is essential to ensure its usefulness as a real time analytical tool. With a view to explore the relevance and applicability of EPC technique as a real time quality control (QC) technique for the routine estimation of 90 Sr content in generator produced 90 Y, a systematic validation study was carried out diligently not only to establish its worthiness but also to broaden its horizon. The ability of the EPC technique to separate trace amounts of Sr 2+ in the presence of large amounts of Y 3+ was verified. The specificity of the technique for Y 3+ was demonstrated with 90 Y obtained by neutron irradiation. The method was validated under real experimental conditions and compared with a QC method described in US Pharmacopeia for detection of 90 Sr levels in 90 Y radiopharmaceuticals. (author)

  14. Trace level determination of precious metals in aqueous medium, U, Th and Zr based nuclear materials by ICP-AES and EDXRF - a comparative study

    International Nuclear Information System (INIS)

    Sengupta, Arijit; Thulasidas, S.K.; Natarajan, V.

    2015-01-01

    A comparative study was carried out to determine Ag, Au and Pt in aqueous samples, uranium, zirconium, and thorium based nuclear fuels and associated materials by CCD based ICP-AES and EDXRF. In ICP-AES, the spectral interference of U, Th, Zr matrices on trace level determination of Ag, Au and Pt were studied for different analytical lines of these analytes. The analytical performance of different lines including detection limits, sensitivity, linear dynamic range etc were studied both by ICP-AES and EDXRF. Though EDXRF technique was known its non destructive nature, the overall analytical performance of ICP-AES technique was found to be superior to EDXRF. Based on the spectral contribution from emission rich matrix elements and the analytical performance of different analytical lines of these analytes, a method was developed for direct determination of these analytes by ICP-AES without chemical separation. The method was validated with synthetic samples and compared with EDXRF technique and conventional ICP-AES technique where the major matrix was chemically separated using suitable organic phase containing selective ligands. The ICP-AES method for direct determination of analytes without chemical separation was found to be simple, less time consuming, without generation of organic waste with acceptable analytical performance

  15. High level radioactive waste management facility design criteria

    International Nuclear Information System (INIS)

    Sheikh, N.A.; Salaymeh, S.R.

    1993-01-01

    This paper discusses the engineering systems for the structural design of the Defense Waste Processing Facility (DWPF) at the Savannah River Site (SRS). At the DWPF, high level radioactive liquids will be mixed with glass particles and heated in a melter. This molten glass will then be poured into stainless steel canisters where it will harden. This process will transform the high level waste into a more stable, manageable substance. This paper discuss the structural design requirements for this unique one of a kind facility. A special emphasis will be concentrated on the design criteria pertaining to earthquake, wind and tornado, and flooding

  16. Development of technical information database for high level waste disposal

    International Nuclear Information System (INIS)

    Kudo, Koji; Takada, Susumu; Kawanishi, Motoi

    2005-01-01

    A concept design of the high level waste disposal information database and the disposal technologies information database are explained. The high level waste disposal information database contains information on technologies, waste, management and rules, R and D, each step of disposal site selection, characteristics of sites, demonstration of disposal technology, design of disposal site, application for disposal permit, construction of disposal site, operation and closing. Construction of the disposal technologies information system and the geological disposal technologies information system is described. The screen image of the geological disposal technologies information system is shown. User is able to search the full text retrieval and attribute retrieval in the image. (S.Y. )

  17. High-Level Waste (HLW) Feed Process Control Strategy

    International Nuclear Information System (INIS)

    STAEHR, T.W.

    2000-01-01

    The primary purpose of this document is to describe the overall process control strategy for monitoring and controlling the functions associated with the Phase 1B high-level waste feed delivery. This document provides the basis for process monitoring and control functions and requirements needed throughput the double-shell tank system during Phase 1 high-level waste feed delivery. This document is intended to be used by (1) the developers of the future Process Control Plan and (2) the developers of the monitoring and control system

  18. Final report on cermet high-level waste forms

    International Nuclear Information System (INIS)

    Kobisk, E.H.; Quinby, T.C.; Aaron, W.S.

    1981-08-01

    Cermets are being developed as an alternate method for the fixation of defense and commercial high level radioactive waste in a terminal disposal form. Following initial feasibility assessments of this waste form, consisting of ceramic particles dispersed in an iron-nickel base alloy, significantly improved processing methods were developed. The characterization of cermets has continued through property determinations on samples prepared by various methods from a variety of simulated and actual high-level wastes. This report describes the status of development of the cermet waste form as it has evolved since 1977. 6 tables, 18 figures

  19. Managing the high level waste nuclear regulatory commission licensing process

    International Nuclear Information System (INIS)

    Baskin, K.P.

    1992-01-01

    This paper reports that the process for obtaining Nuclear Regulatory Commission permits for the high level waste storage facility is basically the same process commercial nuclear power plants followed to obtain construction permits and operating licenses for their facilities. Therefore, the experience from licensing commercial reactors can be applied to the high level waste facility. Proper management of the licensing process will be the key to the successful project. The management of the licensing process was categorized into four areas as follows: responsibility, organization, communication and documentation. Drawing on experience from nuclear power plant licensing and basic management principles, the management requirement for successfully accomplishing the project goals are discussed

  20. Treatment technologies for non-high-level wastes (USA)

    International Nuclear Information System (INIS)

    Cooley, C.R.; Clark, D.E.

    1976-06-01

    Non-high-level waste arising from operations at nuclear reactors, fuel fabrication facilities, and reprocessing facilities can be treated using one of several technical alternatives prior to storage. Each alternative and the associated experience and status of development are summarized. The technology for treating non-high-level wastes is generally available for industrial use. Improved techniques applicable to the commercial nuclear fuel cycle are being developed and demonstrated to reduce the volume of waste and to immobilize it for storage. 36 figures, 59 references

  1. High-level radioactive waste disposal type and theoretical analyses

    International Nuclear Information System (INIS)

    Lu Yingfa; Wu Yanchun; Luo Xianqi; Cui Yujun

    2006-01-01

    Study of high-level radioactive waste disposal is necessary for the nuclear electrical development; the determination of nuclear waste depository type is one of importance safety. Based on the high-level radioactive disposal type, the relative research subjects are proposed, then the fundamental research characteristics of nuclear waste disposition, for instance: mechanical and hydraulic properties of rock mass, saturated and unsaturated seepage, chemical behaviors, behavior of special soil, and gas behavior, etc. are introduced, the relative coupling equations are suggested, and a one dimensional result is proposed. (authors)

  2. Evaluation of solidified high-level waste forms

    International Nuclear Information System (INIS)

    1981-01-01

    One of the objectives of the IAEA waste management programme is to coordinate and promote development of improved technology for the safe management of radioactive wastes. The Agency accomplished this objective specifically through sponsoring Coordinated Research Programmes on the ''Evaluation of Solidified High Level Waste Products'' in 1977. The primary objectives of this programme are to review and disseminate information on the properties of solidified high-level waste forms, to provide a mechanism for analysis and comparison of results from different institutes, and to help coordinate future plans and actions. This report is a summary compilation of the key information disseminated at the second meeting of this programme

  3. Aeon: Synthesizing Scheduling Algorithms from High-Level Models

    Science.gov (United States)

    Monette, Jean-Noël; Deville, Yves; van Hentenryck, Pascal

    This paper describes the aeon system whose aim is to synthesize scheduling algorithms from high-level models. A eon, which is entirely written in comet, receives as input a high-level model for a scheduling application which is then analyzed to generate a dedicated scheduling algorithm exploiting the structure of the model. A eon provides a variety of synthesizers for generating complete or heuristic algorithms. Moreover, synthesizers are compositional, making it possible to generate complex hybrid algorithms naturally. Preliminary experimental results indicate that this approach may be competitive with state-of-the-art search algorithms.

  4. Sterilization, high-level disinfection, and environmental cleaning.

    Science.gov (United States)

    Rutala, William A; Weber, David J

    2011-03-01

    Failure to perform proper disinfection and sterilization of medical devices may lead to introduction of pathogens, resulting in infection. New techniques have been developed for achieving high-level disinfection and adequate environmental cleanliness. This article examines new technologies for sterilization and high-level disinfection of critical and semicritical items, respectively, and because semicritical items carry the greatest risk of infection, the authors discuss reprocessing semicritical items such as endoscopes and automated endoscope reprocessors, endocavitary probes, prostate biopsy probes, tonometers, laryngoscopes, and infrared coagulation devices. In addition, current issues and practices associated with environmental cleaning are reviewed. Copyright © 2011. Published by Elsevier Inc.

  5. Parity dependence of the nuclear level density at high excitation

    International Nuclear Information System (INIS)

    Rao, B.V.; Agrawal, H.M.

    1995-01-01

    The basic underlying assumption ρ(l+1, J)=ρ(l, J) in the level density function ρ(U, J, π) has been checked on the basis of high quality data available on individual resonance parameters (E 0 , Γ n , J π ) for s- and p-wave neutrons in contrast to the earlier analysis where information about p-wave resonance parameters was meagre. The missing level estimator based on the partial integration over a Porter-Thomas distribution of neutron reduced widths and the Dyson-Mehta Δ 3 statistic for the level spacing have been used to ascertain that the s- and p-wave resonance level spacings D(0) and D(1) are not in error because of spurious and missing levels. The present work does not validate the tacit assumption ρ(l+1, J)=ρ(l, J) and confirms that the level density depends upon parity at high excitation. The possible implications of the parity dependence of the level density on the results of statistical model calculations of nuclear reaction cross sections as well as on pre-compound emission have been emphasized. (orig.)

  6. Atmospheric Pressure Effect of Retained Gas in High Level Waste

    International Nuclear Information System (INIS)

    Weber, A.H.

    1999-01-01

    Isolated high level waste tanks in H-Area have unexplained changes in waste-level which have been attributed to environmental effects including pressure, temperature, and relative humidity. Previous studies at SRS have considered waste-level changes from causes not including the presence of gas in the salt cake. This study was undertaken to determine the effect of atmospheric pressure on gas in the salt cake and resultant changes in the supernate level of Tank 41H, and to model that effect if possible. A simple theory has been developed to account for changes in the supernate level in a high level waste tank containing damp salt cake as the response of trapped gases to changes in the ambient pressure. The gas is modeled as an ideal gas retained as bubbles within the interstitial spaces in the salt cake and distributed uniformly throughout the tank. The model does not account for consistent long term increases or decreases in the tank level. Any such trend in the tank level is attributed to changes in the liquid content in the tank (from condensation, evaporation, etc.) and is removed from the data prior to the void estimation. Short term fluctuations in the tank level are explained as the response of the entrained gas volume to changes in the ambient pressure. The model uses the response of the tank level to pressure changes to estimate an average void fraction for the time period of interest. This estimate of the void is then used to predict the expected level response. The theory was applied to three separate time periods of the level data for tank 41H as follows: (1) May 3, 1993 through August 3, 1993, (2) January 23, 1994 through April 21, 1994, and (3) June 4, 1994 through August 24, 1994. A strong correlation was found between fluctuations in the tank level and variations in the ambient pressure. This correlation is a clear marker of the presence of entrained gases in the tank. From model calculations, an average void fraction of 11 percent was estimated to

  7. Transmission Level High Temperature Superconducting Fault Current Limiter

    Energy Technology Data Exchange (ETDEWEB)

    Stewart, Gary [SuperPower, Inc., Schenectady, NY (United States)

    2016-10-05

    The primary objective of this project was to demonstrate the feasibility and reliability of utilizing high-temperature superconducting (HTS) materials in a Transmission Level Superconducting Fault Current Limiter (SFCL) application. During the project, the type of high-temperature superconducting material used evolved from 1st generation (1G) BSCCO-2212 melt cast bulk high-temperature superconductors to 2nd generation (2G) YBCO-based high-temperature superconducting tape. The SFCL employed SuperPower's “Matrix” technology, that offers modular features to enable scale up to transmission voltage levels. The SFCL consists of individual modules that contain elements and parallel inductors that assist in carrying the current during the fault. A number of these modules are arranged in an m x n array to form the current-limiting matrix.

  8. Leaching behavior of simulated high-level waste glass

    International Nuclear Information System (INIS)

    Kamizono, Hiroshi

    1987-03-01

    The author's work in the study on the leaching behavior of simulated high-level waste (HLW) glass were summarized. The subjects described are (1) leach rates at high temperatures, (2) effects of cracks on leach rates, (3) effects of flow rate on leach rates, and (4) an in-situ burial test in natural groundwater. In the following section, the leach rates obtained by various experiments were summarized and discussed. (author)

  9. The tracking of high level waste shipments-TRANSCOM system

    International Nuclear Information System (INIS)

    Johnson, P.E.; Joy, D.S.; Pope, R.B.

    1995-01-01

    The TRANSCOM (transportation tracking and communication) system is the U.S. Department of Energy's (DOE's) real-time system for tracking shipments of spent fuel, high-level wastes, and other high-visibility shipments of radioactive material. The TRANSCOM system has been operational since 1988. The system was used during FY1993 to track almost 100 shipments within the US.DOE complex, and it is accessed weekly by 10 to 20 users

  10. The american high school graduation rate : trends and levels

    OpenAIRE

    Heckman, James J.; LaFontaine, Paul A.

    2008-01-01

    This paper uses multiple data sources and a unified methodology to estimate the trends and levels of the U.S. high school graduation rate. Correcting for important biases that plague previous calculations, we establish that (a) the true high school graduation rate is substantially lower than the official rate issued by the National Center for Educational Statistics; (b) it has been declining over the past 40 years; (c) majority/minority graduation rate differentials are substantial and have n...

  11. High-level neutron coincidence counter (HLNCC): users' manual

    International Nuclear Information System (INIS)

    Krick, M.S.; Menlove, H.O.

    1979-06-01

    This manual describes the portable High-Level Neutron Coincidence Counter (HLNCC) developed at the Los Alamos Scientific Laboratory (LASL) for the assay of plutonium, particularly by inspectors of the International Atomic Energy Agency (IAEA). The counter is designed for the measurement of the effective 240 Pu mass in plutonium samples which may have a high plutonium content. The following topics are discussed: principle of operation, description of the system, operating procedures, and applications

  12. Development of cermets for high-level radioactive waste fixation

    International Nuclear Information System (INIS)

    Aaron, W.S.; Quinby, T.C.; Kobisk, E.H.

    1979-01-01

    A method is currently under development for the solidification and fixation of commercial and defense high-level radioactive wastes in the form of ceramic particles encapsulated by metal, i.e., a cermet. The chemical and physical processing techniques which have been developed and the properties of the resulting cermet bodies are described in this paper. These cermets have the advantages of high thermal conductivity and low leach rates

  13. The tracking of high level waste shipments - TRANSCOM system

    International Nuclear Information System (INIS)

    Johnson, P.E.; Joy, D.S.; Pope, R.B.; Thomas, T.M.; Lester, P.B.

    1994-01-01

    The TRANSCOM (transportation tracking and communication) system is the US Department of Energy's (DOE's) real-time system for tracking shipments of spent fuel, high-level wastes, and other high-visibility shipments of radioactive material. The TRANSCOM system has been operational since 1988. The system was used during FY 1993 to track almost 100 shipments within the US DOE complex, and it is accessed weekly by 10 to 20 users

  14. Partitioning of high level liquid waste: experiences in plant level adoption

    International Nuclear Information System (INIS)

    Manohar, Smitha; Kaushik, C.P.

    2016-01-01

    High Level Radioactive Wastes are presently vitrified in borosilicate matrices in all our back end facilities in our country. This is in accordance with internationally endorsed methodology for the safe management of high level radioactive wastes. Recent advancements in the field of partitioning technology in our group, has presented us with an opportunity to have a fresh perspective on management of high level liquid radioactive wastes streams, that emanate from reprocessing operations. This paper will highlight our experiences with respect to both partitioning studies and vitrification practices, with a focus on waste volume reduction for final disposal. Incorporation of this technique has led to the implementation of the concept of recovering wealth from waste, a marked decrease on the load of disposal in deep geological repositories and serve as a step towards the vision of transmutation of long lived radionuclides

  15. Analysis of trace levels of impurities and hydrogen isotopes in helium purge gas using gas chromatography for tritium extraction system of an Indian lead lithium ceramic breeder test blanket module.

    Science.gov (United States)

    Devi, V Gayathri; Sircar, Amit; Yadav, Deepak; Parmar, Jayraj

    2018-01-12

    In the fusion fuel cycle, the accurate analysis and understanding of the chemical composition of any gas mixture is of great importance for the efficient design of a tritium extraction and purification system or any tritium handling system. Methods like laser Raman spectroscopy and gas chromatography with thermal conductivity detector have been considered for hydrogen isotopes analyses in fuel cycles. Gas chromatography with a cryogenic separation column has been used for the analysis of hydrogen isotopes gas mixtures in general due to its high reliability and ease of operation. Hydrogen isotopes gas mixture analysis with cryogenic columns has been reported earlier using different column materials for percentage level composition. In the present work, trace levels of hydrogen isotopes (∼100 ppm of H 2 and D 2 ) have been analyzed with a Zeolite 5A and a modified γ-Al 2 O 3 column. Impurities in He gas (∼10 ppm of H 2 , O 2 , and N 2 ) have been analyzed using a Zeolite 13-X column. Gas chromatography with discharge ionization detection has been utilized for this purpose. The results of these experiments suggest that the columns developed were able to separate ppm levels of the desired components with a small response time (<6 min) and good resolution in both cases. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. Design concepts of definitive disposal for high level radioactive wastes

    International Nuclear Information System (INIS)

    Badillo A, V.E.; Alonso V, G.

    2007-01-01

    It is excessively known the importance about finding a solution for the handling and disposition of radioactive waste of all level. However, the polemic is centered in the administration of high level radioactive waste and the worn out fuel, forgetting that the more important volumes of waste its are generated in the categories of low level wastes or of very low level. Depending on the waste that will be confined and of the costs, several technological modalities of definitive disposition exist, in function of the depth of the confinement. The concept of deep geologic storage, technological option proposed more than 40 years ago, it is a concept of isolation of waste of long half life placed in a deep underground installation dug in geologic formations that are characterized by their high stability and their low flow of underground water. In the last decades, they have registered countless progresses in technical and scientific aspects of the geologic storage, making it a reliable technical solution supported with many years of scientific work carried out by numerous institutions in the entire world. In this work the design concepts that apply some countries for the high level waste disposal that its liberate heat are revised and the different geologic formations that have been considered for the storage of this type of wastes. (Author)

  17. Ultrasonic energy enhanced the efficiency of advance extraction methodology for enrichment of trace level of copper in serum samples of patients having neurological disorders.

    Science.gov (United States)

    Arain, Mariam S; Kazi, Tasneem G; Afridi, Hassan I; Ali, Jamshed; Akhtar, Asma

    2017-07-01

    An innovative dual dispersive ionic liquid based on ultrasound assisted microextraction (UDIL-μE), for the enrichment of trace levels of copper ion (Cu 2+ ), in serum (blood) of patients suffering from different neurological disorders. The enriched metal ions were subjected to flame atomic absorption spectrometry (FAAS). In the UDIL-μE method, the extraction solvent, ionic liquid, 1-butyl-3-methylimidazolium hexafluorophosphate [C 4 mim][PF 6 ], was dispersed into the aqueous samples using an ultrasonic bath. The(PAN) 1-(2-pyridylazo)-2-naphthol was used as ligand for the complexation of Cu ion in IL (as extracting solvent). The various variables such as sonication time, pH, concentration of complexing agent, time and rate of centrifugation, IL volume that affect the extraction process were optimized. The enhancement factor (EF) and detection limit (LOD) was found under favorable condition was 31 and 0.36μgL -1 , respectively. Reliability of the proposed method was checked by relative standard deviation (%RSD), which was found to be <5%. The accuracy of developed procedure was assured by using certified reference material (CRM) of blood serum. The developed procedure was applied successfully to the analysis of concentration of Cu ion in blood serum of different neurological disorders subjects and referents of same age group. It was observed that the levels of Cu ion was two folds higher in serum samples of neurological disorders patients as related to normal referents of same age group. Copyright © 2016. Published by Elsevier B.V.

  18. Sequential injection/bead injection lab-on-valve schemes for on-line solid phase extraction and preconcentration of ultra-trace levels of heavy metals with determination by ETAAS and ICPMS

    DEFF Research Database (Denmark)

    Wang, Jianhua; Hansen, Elo Harald; Miró, Manuel

    2003-01-01

    are focused on the applications of SI-BI-LOV protocols for on-line microcolumn based solid phase extraction of ultra-trace levels of heavy metals, employing the so-called renewable surface separation and preconcentration manipulatory scheme. Two types of sorbents have been employed as packing material...

  19. Two reports: (i) Correlation properties of delayed neutrons from fast neutron induced fission. (ii) Method and set-up for measurements of trace level content of heavy fissionable elements based on delayed neutron counting

    International Nuclear Information System (INIS)

    Piksaikin, V.M.; Isaev, S.G.; Goverdovski, A.A.; Pshakin, G.M.

    1998-10-01

    The document includes the following two reports: 'Correlation properties of delayed neutrons from fast neutron induced fission' and 'Method and set-up for measurements of trace level content of heavy fissionable elements based on delayed neutron counting. A separate abstract was prepared for each report

  20. Licensing information needs for a high-level waste repository

    International Nuclear Information System (INIS)

    Wright, R.J.; Greeves, J.T.; Logsdon, M.J.

    1985-01-01

    The information needs for licensing findings during the development of a repository for high-level waste (HLW) are described. In particular, attention is given to the information and needs to demonstrate, for construction authorization purposes: repository constructibility, waste retrievability, waste containment, and waste isolation

  1. Site suitability criteria for solidified high level waste repositories

    International Nuclear Information System (INIS)

    Heckman, R.A.; Holdsworth, T.; Towse, D.F.

    1979-01-01

    Activities devoted to development of regulations, criteria, and standards for storage of solidified high-level radioactive wastes are reported. The work is summarized in sections on site suitability regulations, risk calculations, geological models, aquifer models, human usage model, climatology model, and repository characteristics. Proposed additional analytical work is also summarized

  2. Answers to your questions on high-level nuclear waste

    International Nuclear Information System (INIS)

    1987-11-01

    This booklet contains answers to frequently asked questions about high-level nuclear wastes. Written for the layperson, the document contains basic information on the hazards of radiation, the Nuclear Waste Management Program, the proposed geologic repository, the proposed monitored retrievable storage facility, risk assessment, and public participation in the program

  3. The ATLAS Data Acquisition and High Level Trigger system

    International Nuclear Information System (INIS)

    2016-01-01

    This paper describes the data acquisition and high level trigger system of the ATLAS experiment at the Large Hadron Collider at CERN, as deployed during Run 1. Data flow as well as control, configuration and monitoring aspects are addressed. An overview of the functionality of the system and of its performance is presented and design choices are discussed.

  4. Extending Java for High-Level Web Service Construction

    DEFF Research Database (Denmark)

    Christensen, Aske Simon; Møller, Anders; Schwartzbach, Michael Ignatieff

    2003-01-01

    We incorporate innovations from the project into the Java language to provide high-level features for Web service programming. The resulting language, JWIG, contains an advanced session model and a flexible mechanism for dynamic construction of XML documents, in particular XHTML. To support program...

  5. High level cognitive information processing in neural networks

    Science.gov (United States)

    Barnden, John A.; Fields, Christopher A.

    1992-01-01

    Two related research efforts were addressed: (1) high-level connectionist cognitive modeling; and (2) local neural circuit modeling. The goals of the first effort were to develop connectionist models of high-level cognitive processes such as problem solving or natural language understanding, and to understand the computational requirements of such models. The goals of the second effort were to develop biologically-realistic model of local neural circuits, and to understand the computational behavior of such models. In keeping with the nature of NASA's Innovative Research Program, all the work conducted under the grant was highly innovative. For instance, the following ideas, all summarized, are contributions to the study of connectionist/neural networks: (1) the temporal-winner-take-all, relative-position encoding, and pattern-similarity association techniques; (2) the importation of logical combinators into connection; (3) the use of analogy-based reasoning as a bridge across the gap between the traditional symbolic paradigm and the connectionist paradigm; and (4) the application of connectionism to the domain of belief representation/reasoning. The work on local neural circuit modeling also departs significantly from the work of related researchers. In particular, its concentration on low-level neural phenomena that could support high-level cognitive processing is unusual within the area of biological local circuit modeling, and also serves to expand the horizons of the artificial neural net field.

  6. High-Level Overview of Data Needs for RE Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Lopez, Anthony

    2016-12-22

    This presentation provides a high level overview of analysis topics and associated data needs. Types of renewable energy analysis are grouped into two buckets: First, analysis for renewable energy potential, and second, analysis for other goals. Data requirements are similar but and they build upon one another.

  7. The Estuary Guide. Level 3: High School. Draft.

    Science.gov (United States)

    Alexander, Glen; And Others

    Estuaries are marine systems that serve as nurseries for animals, links in the migratory pathways, and habitat for a complex community of organisms. This curriculum guide intended for use at the high school level seeks to teach what estuaries are; provide opportunities to practice decision-making that affects estuaries; and encourage students to…

  8. High-Level waste process and product data annotated bibliography

    International Nuclear Information System (INIS)

    Stegen, G.E.

    1996-01-01

    The objective of this document is to provide information on available issued documents that will assist interested parties in finding available data on high-level waste and transuranic waste feed compositions, properties, behavior in candidate processing operations, and behavior on candidate product glasses made from those wastes. This initial compilation is only a partial list of available references

  9. High-Level Development of Multiserver Online Games

    Directory of Open Access Journals (Sweden)

    Frank Glinka

    2008-01-01

    Full Text Available Multiplayer online games with support for high user numbers must provide mechanisms to support an increasing amount of players by using additional resources. This paper provides a comprehensive analysis of the practically proven multiserver distribution mechanisms, zoning, instancing, and replication, and the tasks for the game developer implied by them. We propose a novel, high-level development approach which integrates the three distribution mechanisms seamlessly in today's online games. As a possible base for this high-level approach, we describe the real-time framework (RTF middleware system which liberates the developer from low-level tasks and allows him to stay at high level of design abstraction. We explain how RTF supports the implementation of single-server online games and how RTF allows to incorporate the three multiserver distribution mechanisms during the development process. Finally, we describe briefly how RTF provides manageability and maintenance functionality for online games in a grid context with dynamic resource allocation scenarios.

  10. High-level radioactive waste repositories site selection plan

    International Nuclear Information System (INIS)

    Castanon, A.; Recreo, F.

    1985-01-01

    A general vision of the high level nuclear waste (HLNW) and/or nuclear spent fuel facilities site selection processes is given, according to the main international nuclear safety regulatory organisms quidelines and the experience from those countries which have reached a larger development of their national nuclear programs. (author)

  11. High-level waste-form-product performance evaluation

    International Nuclear Information System (INIS)

    Bernadzikowski, T.A.; Allender, J.S.; Stone, J.A.; Gordon, D.E.; Gould, T.H. Jr.; Westberry, C.F. III.

    1982-01-01

    Seven candidate waste forms were evaluated for immobilization and geologic disposal of high-level radioactive wastes. The waste forms were compared on the basis of leach resistance, mechanical stability, and waste loading. All forms performed well at leaching temperatures of 40, 90, and 150 0 C. Ceramic forms ranked highest, followed by glasses, a metal matrix form, and concrete. 11 tables

  12. An emergency management demonstrator using the high level architecture

    International Nuclear Information System (INIS)

    Williams, R.J.

    1996-12-01

    This paper addresses the issues of simulation interoperability within the emergency management training context. A prototype implementation in Java of a subset of the High Level Architecture (HLA) is described. The use of Web Browsers to provide graphical user interfaces to HLA is also investigated. (au)

  13. High-level manpower movement and Japan's foreign aid.

    Science.gov (United States)

    Furuya, K

    1992-01-01

    "Japan's technical assistance programs to Asian countries are summarized. Movements of high-level manpower accompanying direct foreign investments by private enterprise are also reviewed. Proposals for increased human resources development include education and training of foreigners in Japan as well as the training of Japanese aid experts and the development of networks for information exchange." excerpt

  14. Reachability Trees for High-level Petri Nets

    DEFF Research Database (Denmark)

    Jensen, Kurt; Jensen, Arne M.; Jepsen, Leif Obel

    1986-01-01

    the necessary analysis methods. In other papers it is shown how to generalize the concept of place- and transition invariants from place/transition nets to high-level Petri nets. Our present paper contributes to this with a generalization of reachability trees, which is one of the other important analysis...

  15. High-level lipase production by Aspergillus candidus URM 5611 ...

    African Journals Online (AJOL)

    The current study evaluated lipase production by Aspergillus candidus URM 5611 through solid state fermentation (SSF) by using almond bran licuri as a new substrate. The microorganism produced high levels of the enzyme (395.105 U gds-1), thus surpassing those previously reported in the literature. The variable ...

  16. Observation of high spin levels in Cs from Ba decay

    Indian Academy of Sciences (India)

    physics pp. 1157–1162. Observation of high spin levels in. 131. Cs from. 131. Ba decay. M SAINATH, DWARAKA RANI RAO*, K VENKATARAMANIAH and P C SOOD. Department of Physics, Sri Sathya Sai Institute of Higher Learning, Prasanthinilayam 515 134, India. £Permanent address: Department of Physics, ...

  17. The 2011 United Nations High-Level Meeting on Non ...

    African Journals Online (AJOL)

    The 2011 United Nations High-Level Meeting on Non- Communicable Diseases: The Africa agenda calls for a 5-by-5 approach. ... The Political Declaration issued at the meeting focused the attention of world leaders and the global health community on the prevention and control of noncommunicable diseases (NCDs).

  18. In-situ nitrite analysis in high level waste tanks

    International Nuclear Information System (INIS)

    O'Rourke, P.E.; Prather, W.S.; Livingston, R.R.

    1992-01-01

    The Savannah River Site produces special nuclear materials used in the defense of the United States. Most of the processes at SRS are primarily chemical separations and purifications. In-situ chemical analyses help improve the safety, efficiency and quality of these operations. One area where in situ fiberoptic spectroscopy can have a great impact is the management of high level radioactive waste. High level radioactive waste at SRS is stored in more than 50 large waste tanks. The waste exists as a slurry of nitrate salts and metal hydroxides at pH's higher than 10. Sodium Nitrite is added to the tanks as a corrosion inhibitor. In-situ fiberoptic probes are being developed to measure the nitrate, nitrite and hydroxide concentrations in both liquid and solid fractions. Nitrite levels can be measured between 0.01M and 1M in a 1mm pathlength optical cell

  19. Radiation transport in high-level waste form

    International Nuclear Information System (INIS)

    Arakali, V.S.; Barnes, S.M.

    1992-01-01

    The waste form selected for vitrifying high-level nuclear waste stored in underground tanks at West Valley, NY is borosilicate glass. The maximum radiation level at the surface of a canister filled with the high-level waste form is prescribed by repository design criteria for handling and disposition of the vitrified waste. This paper presents an evaluation of the radiation transport characteristics for the vitreous waste form expected to be produced at West Valley and the resulting neutron and gamma dose rates. The maximum gamma and neutron dose rates are estimated to be less than 7500 R/h and 10 mRem/h respectively at the surface of a West Valley canister filled with borosilicate waste glass

  20. High-Level Waste Vitrification Facility Feasibility Study

    International Nuclear Information System (INIS)

    D. A. Lopez

    1999-01-01

    A ''Settlement Agreement'' between the Department of Energy and the State of Idaho mandates that all radioactive high-level waste now stored at the Idaho Nuclear Technology and Engineering Center will be treated so that it is ready to be moved out of Idaho for disposal by a compliance date of 2035. This report investigates vitrification treatment of the high-level waste in a High-Level Waste Vitrification Facility based on the assumption that no more New Waste Calcining Facility campaigns will be conducted after June 2000. Under this option, the sodium-bearing waste remaining in the Idaho Nuclear Technology and Engineering Center Tank Farm, and newly generated liquid waste produced between now and the start of 2013, will be processed using a different option, such as a Cesium Ion Exchange Facility. The cesium-saturated waste from this other option will be sent to the Calcine Solids Storage Facilities to be mixed with existing calcine. The calcine and cesium-saturated waste will be processed in the High-Level Waste Vitrification Facility by the end of calendar year 2035. In addition, the High-Level Waste Vitrification Facility will process all newly-generated liquid waste produced between 2013 and the end of 2035. Vitrification of this waste is an acceptable treatment method for complying with the Settlement Agreement. This method involves vitrifying the waste and pouring it into stainless-steel canisters that will be ready for shipment out of Idaho to a disposal facility by 2035. These canisters will be stored at the Idaho National Engineering and Environmental Laboratory until they are sent to a national geologic repository. The operating period for vitrification treatment will be from the end of 2015 through 2035

  1. High-Level Waste Vitrification Facility Feasibility Study

    Energy Technology Data Exchange (ETDEWEB)

    D. A. Lopez

    1999-08-01

    A ''Settlement Agreement'' between the Department of Energy and the State of Idaho mandates that all radioactive high-level waste now stored at the Idaho Nuclear Technology and Engineering Center will be treated so that it is ready to be moved out of Idaho for disposal by a compliance date of 2035. This report investigates vitrification treatment of the high-level waste in a High-Level Waste Vitrification Facility based on the assumption that no more New Waste Calcining Facility campaigns will be conducted after June 2000. Under this option, the sodium-bearing waste remaining in the Idaho Nuclear Technology and Engineering Center Tank Farm, and newly generated liquid waste produced between now and the start of 2013, will be processed using a different option, such as a Cesium Ion Exchange Facility. The cesium-saturated waste from this other option will be sent to the Calcine Solids Storage Facilities to be mixed with existing calcine. The calcine and cesium-saturated waste will be processed in the High-Level Waste Vitrification Facility by the end of calendar year 2035. In addition, the High-Level Waste Vitrification Facility will process all newly-generated liquid waste produced between 2013 and the end of 2035. Vitrification of this waste is an acceptable treatment method for complying with the Settlement Agreement. This method involves vitrifying the waste and pouring it into stainless-steel canisters that will be ready for shipment out of Idaho to a disposal facility by 2035. These canisters will be stored at the Idaho National Engineering and Environmental Laboratory until they are sent to a national geologic repository. The operating period for vitrification treatment will be from the end of 2015 through 2035.

  2. The measurement for level of marine high-temperature and high-pressure vessels

    International Nuclear Information System (INIS)

    Lin Jie.

    1986-01-01

    The various error factors in measurement for level of marine high-temperature and high-pressure vessels are anslysed. The measuring method of error self compensation and its simplification for land use are shown

  3. Development of high-level waste solidification technology 1

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Joon Hyung; Kim, Hwan Young; Kim, In Tae [and others

    1999-02-01

    Spent nuclear fuel contains useful nuclides as valuable resource materials for energy, heat and catalyst. High-level wastes (HLW) are expected to be generated from the R and D activities and reuse processes. It is necessary to develop vitrification or advanced solidification technologies for the safe long-term management of high level wastes. As a first step to establish HLW vitrification technology, characterization of HLWs that would arise at KAERI site, glass melting experiments with a lab-scale high frequency induction melter, and fabrication and property evaluation of base-glass made of used HEPA filter media and additives were performed. Basic study on the fabrication and characterization of candidate ceramic waste form (Synroc) was also carried out. These HLW solidification technologies would be directly useful for carrying out the R and Ds on the nuclear fuel cycle and waste management. (author). 70 refs., 29 tabs., 35 figs.

  4. Trace spaces

    DEFF Research Database (Denmark)

    Fajstrup, Lisbeth; Goubault, Eric; Haucourt, Emmanuel

    2012-01-01

    in the interleaving semantics of a concurrent program, but rather some equivalence classes. The purpose of this paper is to describe a new algorithm to compute such equivalence classes, and a representative per class, which is based on ideas originating in algebraic topology. We introduce a geometric semantics...... of concurrent languages, where programs are interpreted as directed topological spaces, and study its properties in order to devise an algorithm for computing dihomotopy classes of execution paths. In particular, our algorithm is able to compute a control-flow graph for concurrent programs, possibly containing...... loops, which is “as reduced as possible” in the sense that it generates traces modulo equivalence. A preliminary implementation was achieved, showing promising results towards efficient methods to analyze concurrent programs, with very promising results compared to partial-order reduction techniques....

  5. The Role of Trace Elements in Tinnitus.

    Science.gov (United States)

    Yaşar, Mehmet; Şahin, Mehmet İlhan; Karakükçü, Çiğdem; Güneri, Erhan; Doğan, Murat; Sağıt, Mustafa

    2017-03-01

    In this study, we aimed to investigate the role of three trace elements, namely, zinc, copper, and lead, in tinnitus by analyzing the serum level of copper and lead and both the serum and tissue level of zinc. Eighty patients, who applied to outpatient otolaryngology clinic with the complaints of having tinnitus, and 28 healthy volunteers were included. High-frequency audiometry was performed, and participants who had hearing loss according to the pure tone average were excluded; tinnitus frequency and loudness were determined and tinnitus reaction questionnaire scores were obtained from the patients. Of all the participants, serum zinc, copper, and lead values were measured; moreover, zinc levels were examined in hair samples. The levels of trace elements were compared between tinnitus and control groups. The level of copper was found to be significantly lower in the tinnitus group (p = 0.02), but there was no significant difference between the groups in terms of the levels of zinc, neither in serum nor in hair, and lead in serum (p > 0.05). The lack of trace elements, especially that of "zinc," have been doubted for the etiopathogenesis of tinnitus in the literature; however, we only found copper levels to be low in patients having tinnitus.

  6. Trace metal emissions from the Estonian oil shale fired power

    DEFF Research Database (Denmark)

    Aunela-Tapola, Leena A.; Frandsen, Flemming; Häsänen, Erkki K.

    1998-01-01

    Emission levels of selected trace metals from the Estonian oil shale fired power plant were studied. The plant is the largest single power plant in Estonia with an electricity production capacity of 1170 MWe (1995). Trace metals were sampled from the flue gases by a manual method incorporating...... in the flue gases of the studied oil shale plant contribute, however, to clearly higher total trace metal emission levels compared to modern coal fired power plants. Although the old electrostatic precipitators in the plant have been partly replaced by state-of-the-art electrostatic precipitators...... a two-fraction particle sampling and subsequent absorption of the gaseous fraction. The analyses were principally performed with ICP-MS techniques. The trace metal contents of Estonian oil shale were found to be in the same order of magnitude as of coal on average. The high total particle concentrations...

  7. A high Tc superconducting liquid nitrogen level sensor

    International Nuclear Information System (INIS)

    Jin, J. X.; Liu, H. K.; Dou, S. X.; Grantham, C.; Beer, J.

    1996-01-01

    Full text: The dramatic resistance change in the superconducting-normal transition temperature range enables a high T c superconductor to be considered for designing a liquid nitrogen level sensor. A (Bi,Pb) 2 Sr 2 Ca 2 Cu 3 O 10+x Ag clad superconducting wire is selected and tested as a continuous liquid nitrogen level sensor to investigate the possibility for this application. The (Bi,Pb) 2 Sr 2 Ca 2 Cu 3 O 10+x Ag clad superconducting wire has approximately 110 K critical temperature, with more flexible and stable properties compared with bulk shape ceramic high T c superconductors. The voltage drops across the sensor are tested with different immersion lengths in liquid nitrogen. The accuracy of the HTS sensor is analysed with its dR/dT in the superconducting-normal transition range. The voltage signal is sensitive to liquid nitrogen level change, and this signal can be optimized by controlling the transport current. The problems of the Ag clad superconductor are that the Ag sheath thermal conductivity is very high, and the sensor normal resistance is low. These are the main disadvantages for using such a wire as a continuous level sensor. However, a satisfactory accuracy can be achieved by control of the transport current. A different configuration of the wire sensor is also designed to avoid this thermal influence

  8. Lumbar disc herniation at high levels : MRI and clinical findings

    International Nuclear Information System (INIS)

    Paek, Chung Ho; Kwon, Soon Tae; Lee, Jun Kyu; Ahn, Jae Sung; Lee, Hwan Do; Chung, Yon Su; Jeong, Ki Ho; Cho, Jun Sik

    1999-01-01

    To assess the frequency, location, associated MR findings, and clinical symptoms of the high level lumbar disc herniation(HLDH). A total of 1076 patients with lunbar disc herniation were retrospectively reviewed. MR images of 41 of these with HLDH(T12-L1, L1-2, L2-3) were analysed in terms of frequency, location, and associated MR findings, and correlated with clinical symptoms of HLDH. The prevalence of HLDH was 3.8%(41/1076). HLDH was located at T12-L1 level in four patients(10%), at L1-2 level in 14(34%), at L2-3 level in 21(51%), and at both L1-2 and L2-3 levels in two. The age of patients ranged from 20 to 72 years (mean, 44), and there were 26 men and 16 women. In 11(27%), whose mean age was 32 years, isolated disc herniation was limited to these high lumbar segments. The remaining 30 patients had HLDH associated with variable involvement of the lower lumbar segments. Associated lesions were as follow : lower level disc herniation(14 patients, 34%); apophyseal ring fracture(8 patients, 19%); Schmorl's node and spondylolisthesis (each 6 patients, each 14%); spondylolysis(3 patients, 7%); and retrolisthesis(2 patients, 5%). In 20 patients(49%) with HLDH(n=41), there was a previous history of trauma. Patients with HLDH showed a relatively high incidence of associated coexisting abnormalities such as lower lumbar disc herniation, apophyseal ring fracture, Schmorl's node, spondylolysis, and retrolisthesis. In about half of all patients with HLDH there was a previous history of trauma. The mean age of patients with isolated HLDH was lower; clinical symptoms of the condition were relatively nonspecific and their incidence was low

  9. Lumbar disc herniation at high levels : MRI and clinical findings

    Energy Technology Data Exchange (ETDEWEB)

    Paek, Chung Ho; Kwon, Soon Tae; Lee, Jun Kyu; Ahn, Jae Sung; Lee, Hwan Do; Chung, Yon Su; Jeong, Ki Ho; Cho, Jun Sik [Chungnam National Univ. College of Medicine, Taejon (Korea, Republic of)

    1999-04-01

    To assess the frequency, location, associated MR findings, and clinical symptoms of the high level lumbar disc herniation(HLDH). A total of 1076 patients with lunbar disc herniation were retrospectively reviewed. MR images of 41 of these with HLDH(T12-L1, L1-2, L2-3) were analysed in terms of frequency, location, and associated MR findings, and correlated with clinical symptoms of HLDH. The prevalence of HLDH was 3.8%(41/1076). HLDH was located at T12-L1 level in four patients(10%), at L1-2 level in 14(34%), at L2-3 level in 21(51%), and at both L1-2 and L2-3 levels in two. The age of patients ranged from 20 to 72 years (mean, 44), and there were 26 men and 16 women. In 11(27%), whose mean age was 32 years, isolated disc herniation was limited to these high lumbar segments. The remaining 30 patients had HLDH associated with variable involvement of the lower lumbar segments. Associated lesions were as follow : lower level disc herniation(14 patients, 34%); apophyseal ring fracture(8 patients, 19%); Schmorl's node and spondylolisthesis (each 6 patients, each 14%); spondylolysis(3 patients, 7%); and retrolisthesis(2 patients, 5%). In 20 patients(49%) with HLDH(n=41), there was a previous history of trauma. Patients with HLDH showed a relatively high incidence of associated coexisting abnormalities such as lower lumbar disc herniation, apophyseal ring fracture, Schmorl's node, spondylolysis, and retrolisthesis. In about half of all patients with HLDH there was a previous history of trauma. The mean age of patients with isolated HLDH was lower; clinical symptoms of the condition were relatively nonspecific and their incidence was low.

  10. To trace the water movements in the sites of nuclear waste repositories by chlorine-36

    International Nuclear Information System (INIS)

    Sun Zhanxue

    1995-01-01

    Chlorine-36 tracing of the water movements in the potential high-level radioactive waste disposal repository sites has been briefly reviewed. The application of this method to the tracing of precipitation infiltration into the unsaturated zone and the water movement in the saturated zone, to the dating of groundwater and the study of solute migration rates have been discussed

  11. Cermet high level waste forms: a pregress report

    International Nuclear Information System (INIS)

    Aaron, W.S.; Quinby, T.C.; Kobisk, E.H.

    1978-06-01

    The fixation of high level radioactive waste from both commercial and DOE defense sources as cermets is currently under study. This waste form consists of a continuous iron-nickel base metal matrix containing small particles of fission product oxides. Preliminary evaluations of cermets fabricated from a variety of simulated wastes indicate they possess properties providing advantages over other waste forms presently being considered, namely thermal conductivity, waste loading levels, and leach resistance. This report describes the progress of this effort, to date, since its initiation in 1977

  12. Low level neutron monitoring using high pressure 3He detectors

    International Nuclear Information System (INIS)

    Pszona, S.

    1995-01-01

    Three detectors, two spherical proportional counters and an ionisation chamber, all filled with 3 He to pressures of 160 kPa, 325 kPa and 1 MPa respectively have been experimentally studied with respect to their use for low level neutron monitoring. The ambient dose equivalent responses and the energy resolutions of these detectors have been determined. It is shown that spectral analysis of the signals from these detectors not only gives high sensitivity with regard to ambient dose equivalent but also improves the quality of the measurements. A special instrumentation for low level neutron monitoring is described in which a quality control method has been implemented. (Author)

  13. Very-high-level neutral-beam control system

    International Nuclear Information System (INIS)

    Elischer, V.; Jacobson, V.; Theil, E.

    1981-10-01

    As increasing numbers of neutral beams are added to fusion machines, their operation can consume a significant fraction of a facility's total resources. LBL has developed a very high level control system that allows a neutral beam injector to be treated as a black box with just 2 controls: one to set the beam power and one to set the pulse duration. This 2 knob view allows simple operation and provides a natural base for implementing even higher level controls such as automatic source conditioning

  14. Overview of high-level waste management accomplishments

    International Nuclear Information System (INIS)

    Lawroski, H.; Berreth, J.R.; Freeby, W.A.

    1980-01-01

    Storage of power reactor spent fuel is necessary at present because of the lack of reprocessing operations particularly in the U.S. By considering the above solidification and storage scenario, there is more than reasonable assurance that acceptable, stable, low heat generation rate, solidified waste can be produced, and safely disposed. The public perception of no waste disposal solutions is being exploited by detractors of nuclear power application. The inability to even point to one overall system demonstration lends credibility to the negative assertions. By delaying the gathering of on-line information to qualify repository sites, and to implement a demonstration, the actions of the nuclear power detractors are self serving in that they can continue to point out there is no demonstration of satisfactory high-level waste disposal. By maintaining the liquid and solidified high-level waste in secure above ground storage until acceptable decay heat generation rates are achieved, by producing a compatible, high integrity, solid waste form, by providing a second or even third barrier as a compound container and by inserting the enclosed waste form in a qualified repository with spacing to assure moderately low temperature disposal conditions, there appears to be no technical reason for not progressing further with the disposal of high-level wastes and needed implementation of the complete nuclear power fuel cycle

  15. Trace element determination using static high-sensitivity inductively coupled plasma optical emission spectrometry (SHIP-OES).

    Science.gov (United States)

    Engelhard, Carsten; Scheffer, Andy; Nowak, Sascha; Vielhaber, Torsten; Buscher, Wolfgang

    2007-02-05

    A low-flow air-cooled inductively coupled plasma (ICP) design for optical emission spectrometry (OES) with axial plasma viewing is described and an evaluation of its analytical capabilities in trace element determinations is presented. Main advantage is a total argon consumption of 0.6 L min(-1) in contrast to 15 L min(-1) using conventional ICP sources. The torch was evaluated in trace element determinations and studied in direct comparison with a conventional torch under the same conditions with the same OES system, ultrasonic nebulization (USN) and single-element optimization. A variety of parameters (x-y-position of the torch, rf power, external air cooling, gas flow rates and USN operation parameters) was optimized to achieve limits of detection (LOD) which are competitive to those of a conventional plasma source. Ionic to atomic line intensity ratios for magnesium were studied at different radio frequency (rf) power conditions and different sample carrier gas flows to characterize the robustness of the excitation source. A linear dynamic range of three to five orders of magnitude was determined under compromise conditions in multi-element mode. The accuracy of the system was investigated by the determination of Co, Cr, Mn, Zn in two certified reference materials (CRM): CRM 075c (Copper with added impurities), and CRM 281 (Trace elements in rye grass). With standard addition values of 2.44+/-0.04 and 3.19+/-0.21 microg g(-1) for Co and Mn in the CRM 075c and 2.32+/-0.09, 81.8+/-0.4, 32.2+/-3.9 for Cr, Mn and Zn, respectively, were determined in the samples and found to be in good agreement with the reported values; recovery rates in the 98-108% range were obtained. No influence on the analysis by the matrix load in the sample was observed.

  16. A high-throughput solid-phase extraction microchip combined with inductively coupled plasma-mass spectrometry for rapid determination of trace heavy metals in natural water.

    Science.gov (United States)

    Shih, Tsung-Ting; Hsieh, Cheng-Chuan; Luo, Yu-Ting; Su, Yi-An; Chen, Ping-Hung; Chuang, Yu-Chen; Sun, Yuh-Chang

    2016-04-15

    Herein, a hyphenated system combining a high-throughput solid-phase extraction (htSPE) microchip with inductively coupled plasma-mass spectrometry (ICP-MS) for rapid determination of trace heavy metals was developed. Rather than performing multiple analyses in parallel for the enhancement of analytical throughput, we improved the processing speed for individual samples by increasing the operation flow rate during SPE procedures. To this end, an innovative device combining a micromixer and a multi-channeled extraction unit was designed. Furthermore, a programmable valve manifold was used to interface the developed microchip and ICP-MS instrumentation in order to fully automate the system, leading to a dramatic reduction in operation time and human error. Under the optimized operation conditions for the established system, detection limits of 1.64-42.54 ng L(-1) for the analyte ions were achieved. Validation procedures demonstrated that the developed method could be satisfactorily applied to the determination of trace heavy metals in natural water. Each analysis could be readily accomplished within just 186 s using the established system. This represents, to the best of our knowledge, an unprecedented speed for the analysis of trace heavy metal ions. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. German Spent Nuclear Fuel Legacy: Characteristics and High-Level Waste Management Issues

    Directory of Open Access Journals (Sweden)

    A. Schwenk-Ferrero

    2013-01-01

    Full Text Available Germany is phasing-out the utilization of nuclear energy until 2022. Currently, nine light water reactors of originally nineteen are still connected to the grid. All power plants generate high-level nuclear waste like spent uranium or mixed uranium-plutonium dioxide fuel which has to be properly managed. Moreover, vitrified high-level waste containing minor actinides, fission products, and traces of plutonium reprocessing loses produced by reprocessing facilities has to be disposed of. In the paper, the assessments of German spent fuel legacy (heavy metal content and the nuclide composition of this inventory have been done. The methodology used applies advanced nuclear fuel cycle simulation techniques in order to reproduce the operation of the German nuclear power plants from 1969 till 2022. NFCSim code developed by LANL was adopted for this purpose. It was estimated that ~10,300 tonnes of unreprocessed nuclear spent fuel will be generated until the shut-down of the ultimate German reactor. This inventory will contain ~131 tonnes of plutonium, ~21 tonnes of minor actinides, and 440 tonnes of fission products. Apart from this, ca.215 tonnes of vitrified HLW will be present. As fission products and transuranium elements remain radioactive from 104 to 106 years, the characteristics of spent fuel legacy over this period are estimated, and their impacts on decay storage and final repository are discussed.

  18. Geological disposal of high-level radioactive waste. Conceptual repository design in hard rock

    International Nuclear Information System (INIS)

    Beale, H.; Griffin, J.R.; Davies, J.W.; Burton, W.R.

    1980-01-01

    The paper gives an interim report on UK studies on possible designs for a repository for vitrified high-level radioactive waste in crystalline rock. The properties of the waste are described and general technical considerations of consequences of disposal in the rock. As an illustration, two basic designs are described associated with pre-cooling in an intermediate store. Firstly, a 'wet repository' is outlined wherein canisters are sealed up closely in boreholes in the rock in regions of low groundwater movement. Secondly, a 'dry repository' above sea level is described where emplacement in tunnels is followed by a loose backfill containing activity absorbers. A connection to deep permeable strata maintains water levels below emplacement positions. Variants on the two basic schemes (tunnel emplacement in a wet repository and in situ cooling) are also assessed. It is concluded that all designs discussed produce a size of repository feasible for construction in the UK. Further, (1) a working figure of 100 0 C per maximum rock temperature is not exceeded, (2) no insuperable engineering problems have so far been found, though rock mechanics studies are at an early stage; (3) it is not possible to discount the escape of a few long-lived 'man-made' isotopes. A minute increment to natural activity in the biosphere may occur from traces of uranium and its decay chains; (4) at this stage, all the designs are still possible candidates for the construction of a UK repository. (author)

  19. Suitability of different containers for the sampling and storage of biogas and biomethane for the determination of the trace-level impurities--A review.

    Science.gov (United States)

    Arrhenius, Karine; Brown, Andrew S; van der Veen, Adriaan M H

    2016-01-01

    The traceable and accurate measurement of biogas impurities is essential in order to robustly assess compliance with the specifications for biomethane being developed by CEN/TC408. An essential part of any procedure aiming to determinate the content of impurities is the sampling and the transfer of the sample to the laboratory. Key issues are the suitability of the sample container and minimising the losses of impurities during the sampling and analysis process. In this paper, we review the state-of-the-art in biogas sampling with the focus on trace impurities. Most of the vessel suitability studies reviewed focused on raw biogas. Many parameters need to be studied when assessing the suitability of vessels for sampling and storage, among them, permeation through the walls, leaks through the valves or physical leaks, sorption losses and adsorption effects to the vessel walls, chemical reactions and the expected initial concentration level. The majority of these studies looked at siloxanes, for which sampling bags, canisters, impingers and sorbents have been reported to be fit-for-purpose in most cases, albeit with some limitations. We conclude that the optimum method requires a combination of different vessels to cover the wide range of impurities commonly found in biogas, which have a wide range of boiling points, polarities, water solubilities, and reactivities. The effects from all the parts of the sampling line must be considered and precautions must be undertaken to minimize these effects. More practical suitability tests, preferably using traceable reference gas mixtures, are needed to understand the influence of the containers and the sampling line on sample properties and to reduce the uncertainty of the measurement. Copyright © 2015 Elsevier B.V. All rights reserved.

  20. Impact of geo-chemical environment of subsurface water on the measurement of ultra trace level of uranium in ground water by adsorptive stripping voltammetry

    International Nuclear Information System (INIS)

    Singhal, R.K.; Preetha, J.; Karpe, Rupali; Ajay Kumar; Hegde, A.G.

    2005-01-01

    During the present work, impacts of cations (Ca 2+ , Mg 2+ , K + ,), anions (Cl -1 , F -1 , and PO 4 3- ) and DOC (Dissolved Organic Carbon) on the measurement of ultra trace level of uranium (VI) in subsurface water by adsorptive stripping voltammetry (AdSV) is studied. The concentrations of these anions, cations and DOC in subsurface water changes due to change in the geo-chemical environment at different locations. In AdSV, concentration of U was determined by forming an uranium-chloranilic acid complex (2,5-dichloro- 3,6-dihydroxy-1,4-benzoquinone). AdSV measurements were carried out in the differential pulse (DP) mode using a pulse amplitude of -50 mV, a pulse time of 30 ms and a potential step of 4 mV. The detection limit, was calculated to 2+ , Mg 2+ , K + ) and anions (Cl -1 , F -1 , and PO 4 3- ) was carried out by using Ion Chromatography. Ground water samples were spiked with varying degree of cations, anions and DOC (dissolved organic carbon). DOC in ground waters were measured by Total Organic Carbon (TOC) analyzer. Various experiments show that analysis of uranium in the concentration range of 2+ , Mg 2+ , K + , Cl -1 , F -1 , and PO 4 3- . In case of DOC there is no interference observed in the concentration range of 0.02-15 ppm but beyond 15 ppm the concentration of uranium decrease sharply. Further, if DOC exceeded 16 ppm it was not possible to do the analysis of uranium by AdSV without destruction of DOC, as DOC is surface active organic compound and accumulates on Hg electrode preferentially over uranium-chloroanailic complex. (author)