WorldWideScience

Sample records for trace elements analysis

  1. Trace element analysis of nail polishes

    International Nuclear Information System (INIS)

    Misra, G.; Mittal, V.K.; Sahota, H.S.

    1999-01-01

    Instrumental neutron activation analysis (INAA) technique was used to measure the concentrations of various trace elements in nail polishes of popular Indian and foreign brands. The aim of the present experiment was to see whether trace elements could distinguish nail polishes of different Indian and foreign brands from forensic point of view. It was found that cesium can act as a marker to differentiate foreign and Indian brands. (author)

  2. Trace Element Analysis of Selenium

    International Nuclear Information System (INIS)

    Soliman, M.S.A.

    2010-01-01

    The present thesis divided into four chapters as follows:Chapter (1):This chapter contains an introduction on different oxidation states of organic and inorganic species for selenium in environmental and biological samples, the process for separation of selenium from these samples and the importance of selenium as a component for these samples. Also gives notes about the techniques which are used in the elemental analysis for selenium species and the detection limits for selenium in these techniques, selenium species in human body and the importance of these species in protecting the body from the different types of cancer and the sources of selenium in environmental samples (soil and water) and distribution levels of selenium in these samples.Chapter (2):This chapter is divided into two parts :The first part deals with the sample collection process for environmental samples (underground water, soil) and the wet digestion ( microwave digestion ) process of soil samples. It also contains the theory of work of the closed microwave digestion system.The second part contains detailed information concerning the theoretical considerations of the used analytical techniques. These techniques include Hydride generation - Atomic Absorption Spectrometer (HG-AAS), Inductively Coupled Plasma Mass Spectrometer (ICP-MS) and Neutron Activation Analysis (NAA).Chapter (3): This chapter includes the methods of sampling, sample preparation, and sample digesition. The measures of quality assurance are disscused in this chapter. It describes in details the closed microwave digestion technique and the analytical methods used in this study which are present in Central Laboratory for Elemental and Isotopic Analysis (CLEIA) and the Egypt Second Research Reactor (ETRR-2). The described techniques are Atomic Absorption Spectrometer (AAS 6 vario, Analytical Jena GmbH, Germany), JMS-PLASMAX2 Mass Spectrometer (ICP-MS) and the Egypt Second Research Reactor (NAA).

  3. Examination of paints by trace element analysis.

    Science.gov (United States)

    Krishnan, S S

    1976-10-01

    Trace element analysis using neutron activation analysis is effective and valuable, particularly in the examination of white household paint. Although physical appearance and resin composition are generally similar in these paint samples, trace element composition provides an effective way of distinguishing among them. In the case of automobile paint samples, NAA serves as an important additional technique for discrimination. The technique is important when sample sizes are very small. The technique developed takes a few minutes for sample preparation, a few hours of irradiation time (during which the examiner's presence is not required), and then a few minutes for counting and obtaining quantitative multielement concentration patterns. A technician can easily handle 30 to 50 samples per day.

  4. Trace-element analysis in environmental sciences

    International Nuclear Information System (INIS)

    Valkovic, V.; Moschini, G.

    1988-01-01

    The use of charged-particle accelerators in trace-element analysis in the field of environmental sciences is described in this article. Nuclear reactions, charged-particle-induced X-ray emission as well as other nuclear and atomic processes can be used individually, or combined, in developing adequate analytical systems. In addition to concentration levels, concentration levels, concentration profiles can be measured, resulting in unique information. Some examples of experiments performed are described together with the suggestions for future measurements [pt

  5. Trace element analysis in soy sauce. 2

    International Nuclear Information System (INIS)

    Haruyama, Yoichi; Saito, Manabu; Tomita, Michio; Yoshida, Koji.

    1994-01-01

    Trace elements in four kinds of soybean and three kinds of salt have been measured by means of in-air PIXE. In soybeans, which were made in Japan, America, Canada and China, six kinds of trace elements were detected, such as Mn, Fe, Ni, Cu, Zn and Br. The concentration of these elements varied depending on the place they were made. American soybean showed characteristic feature compared with other soybeans. As to the bromine concentration, American soybean contains ten times as much as Japanese one. In salts Br and Sr were detected. (author)

  6. Application of trace element analysis to determine trace element concentrations in the field of medicine

    International Nuclear Information System (INIS)

    Kasperek, K.; Feinendegen, L.E.

    1976-01-01

    Applied trace elements research in medicine requires a sensitive and efficient technique of trace elements analysis such as, e.g., neutron activation analysis. Essential trace elements act as stabilisators (iron in haem), structural elements (silicium in fibrous tissue), in hormones (iodine in thyroid hormone), in vitamins (cobalt in vitamin B 12), and in enzymes. Most of the essential trace elements act as coenzymes or in coenzymes or directly as metabolic catalysators. For example, selenium deficiency in PKU and maple syrup patients receiving dietary treatment can be detected by determining the selenium content of the serum, while low selenium values in the whole blood indicate liver cirrhosis. Acrodermatitis enteropathica can be diagnosed by determinig zinc in the serum, and pancreatic insufficiency by determining zinc in the pancreatic juice. Zinc also plays a part in disturbances of growth, in the healing of wounds, and in the insulin metabolism. Cobalt is important in some types of anaemia and in myocardiopathies. Trace elements are also necessary in the treatment of diseases, e.g. iron cobalt in some types of anaemia, and zinc in the delayed healing of wounds in the postoperative phase and in acrodermatitis enteropathica. Chromium is now being tested for the treatment of diabetes mellitus, and fluorides may be of interest in the treatment of osteoporosis. Finally, trace elements are important in the aetiology of acute poisoning, in nutrition, and in environmental protection. (orig./AK) [de

  7. Trace elements in termites by PIXE analysis

    Energy Technology Data Exchange (ETDEWEB)

    Yoshimura, T. E-mail: tsuyoshi@termite.kuwri.kyoto-u.ac.jp; Kagemori, N.; Kawai, S.; Sera, K.; Futatsugawa, S

    2002-04-01

    Trace elements in a Japanese subterranean xylophagous termite, Coptotermes formosanus Shiraki, were analyzed by the PIXE method. The total amount of the 14 predominant elements out of 27 detected in an intact termite was higher in a soldier termite (23 000 {mu}g/g) than in a worker termite (10 000 {mu}g/g). A block of wood (Pinus densiflora Sieb. et Zucc.) for termite feed had a much lower concentration (3600 {mu}g/g) compared with that in an intact termite. This probably relates the functional bio-condensation and/or bio-recycling of trace elements in C. formosanus. When a termite was separated into three anatomical parts, head, degutted body and gut, the worker gut contained the highest total amount of the 14 predominant measured elements (31 000 {mu}g/g). This might be correlated with the higher activity of food digestion and energy production in the worker gut. Moreover, the mandible of the soldier head, with an exoskeleton that is intensely hardened, showed a preferential distribution of Mn and Fe. These results suggest that the characteristic localization of elements will be closely related to the functional role of the individual anatomical part of C. formosanus.

  8. Instrumental trace element analysis of California market milk

    International Nuclear Information System (INIS)

    Ragaini, R.C.; Langhorst, A.L.; Ralston, H.R.; Heft, R.

    1975-01-01

    Trace element analysis for 15 elements (Zn, Na, Br, Rb, Sr, Mg, Al, Ca, Cl, I, K, Fe, Co, Se, Cs) was carried out on 32 samples of California market milk and 6 samples of Colorado milk in a pilot study of toxic and nutrient trace elements in the soil-forage-cow-milk food chain. The techniques of instrumental neutron activation analysis and x-ray fluorescence analysis are described. Sample collection, preparation, analysis, and data reduction procedures are discussed. The mean values and variations of trace element concentrations in milk are compared to data from other studies. (U.S.)

  9. Probing Trace-elements in Bitumen by Neutron Activation Analysis

    NARCIS (Netherlands)

    Nahar, S.N.; Schmets, A.J.M.; Scarpas, Athanasios

    Trace elements and their concentrations play an important role in both chemical and physical properties of bitumen. Instrumental Neutron Activation Analysis (INAA) has been applied to determine the concentration of trace elements in bitumen. This method requires irradiation of the material with

  10. Preparation of fingernails for trace element analysis.

    Science.gov (United States)

    Bank, H L; Robson, J; Bigelow, J B; Morrison, J; Spell, L H; Kantor, R

    1981-10-26

    There are substantial differences in the reported elemental composition of human nails. Most investigators have used extensive washing procedures to minimize environmental contamination, however, such washing poses the risk of extraction of elements bound to the nail matrix. To determine if a portion of this variability could be accounted for by the "washing solutions" used by different investigators, nails were washed in nine solvents previously used for cleaning nails and their residual elemental composition measured by atomic absorption spectroscopy or energy dispersion analysis. In general, treatment with organic solvents resulted in less elemental loss than did treatment with aqueous detergents, while aqueous acids caused the greatest loss. Organic solvents more readily extracted iron and magnesium than calcium, copper and zinc. Virtually all of the magnesium was extracted by distilled water or aqueous detergents.

  11. PIXE analysis of trace elements in cetacean teeth

    International Nuclear Information System (INIS)

    Mitani, Yoko; Arai, Nobuaki; Sakamoto, Wataru; Yoshida, Koji

    1997-01-01

    PIXE was adopted for analysis of trace elements in teeth of two species of cetaceans, sperm whale (Physeter microcephalus) and pantropical spotted dolphin (Stenella attenuata). The analyses were performed along with the growth layer of the teeth, which is formed annually, suitable for age determination. Mn, Fe, Cu, Zu and Sr were detected in the teeth of sperm whale and pantropical spotted dolphin. Among these trace elements, gradual increase was observed for Zn/Ca ratio in the sperm whale's teeth. (author)

  12. Trace and ultratrace level elemental and speciation analysis

    International Nuclear Information System (INIS)

    Arunachalam, J.

    2012-01-01

    Accurate determination of elements present at parts per million and billion levels in various matrices is a growing requirement in different fields. In environmental sciences various trace elements need to be analyzed so as establish the dispersal models of pollutants or the adequacy of effluent treatment prior to discharge into water bodies. The issues of bioaccumulation and magnification are important in aquatic systems. In nutrition and biochemistry one has to establish the bio-availability of essential and toxic elemental species as toxic elements prevent assimilation of essential elements. Fission and fusion technologies use a variety of structural materials requiring many trace elements to be present at levels strictly below the specified levels. Ultra-pure bulk semiconductor materials are required for fabrication devices. In metallurgy and materials sciences too, various trace elements are known to influence the properties. In the emerging fields like nanotechnology, it is necessary to understand the passage and accumulation of nano-particles inside the cells, through trace analysis. Many analytical techniques exist which can provide the concentration information in the bulk materials with good accuracy. They include ICP-AES, FAAS, and ICP-MS, which are solution based techniques. Direct solid state analytical techniques are Glow Discharge Mass Spectrometry (GDMS) and XRF. Accelerator based ion-beam analysis techniques can provide information on concentration and depth profiles of different elements in layered structures. Hyphenated techniques such as HPLC/lC-ICPMS, are helpful in identifying various chemical oxidation states in which a given element might be present in a matrix, which is termed as speciation analysis. This presentation will include the existing analytical competencies and the laboratory requirements for trace and ultra trace element elemental and speciation analyses and their applications. (author)

  13. Trace elements in coloured opals using neutron activation analysis

    Energy Technology Data Exchange (ETDEWEB)

    McOrist, G.D.; Smallwood, A. [Australian Nuclear Science and Technology Organisation, Lucas Heights, NSW (Australia)

    1996-12-31

    Neutron activation analysis (NAA) is a technique particularly suited to analysing opals since it is non-destructive and the silica matrix of opals is not prone to significant activation. It was used to determine the concentration of trace elements in 50 samples of orange, yellow, green, blue and pink opals as well as 18 samples of colourless opals taken from a number of recognised fields in Australia, Peru, Mexico and USA. The results were then evaluated to determine if a relationship existed between trace element content and opal colour. The mean concentration of most of the elements found in orange, yellow and colourless opals were similar with few exceptions. This indicated that, for these samples, colour is not related to the trace elements present. However, the trace element profile of the green, pink and blue opals was found to be significantly different with each colour having a much higher concentration of certain trace elements when compared with all other opals analysed. 7 refs.

  14. Trace elements in coloured opals using neutron activation analysis

    International Nuclear Information System (INIS)

    McOrist, G.D.; Smallwood, A.

    1996-01-01

    Neutron activation analysis (NAA) is a technique particularly suited to analysing opals since it is non-destructive and the silica matrix of opals is not prone to significant activation. It was used to determine the concentration of trace elements in 50 samples of orange, yellow, green, blue and pink opals as well as 18 samples of colourless opals taken from a number of recognised fields in Australia, Peru, Mexico and USA. The results were then evaluated to determine if a relationship existed between trace element content and opal colour. The mean concentration of most of the elements found in orange, yellow and colourless opals were similar with few exceptions. This indicated that, for these samples, colour is not related to the trace elements present. However, the trace element profile of the green, pink and blue opals was found to be significantly different with each colour having a much higher concentration of certain trace elements when compared with all other opals analysed. 7 refs

  15. Trace element analysis in rheumatoid arthritis under chrysotherapy

    International Nuclear Information System (INIS)

    Lecomte, R.; Paradis, P.; Monaro, S.; Barrette, M.; Lamoureux, G.; Menard, H.A.

    1981-01-01

    Proton induced X-ray emission (PIXE) analysis is used to measure trace element concentrations in blood serum from patients with rheumatoid arthritis. Initially trace element contaminations in blood-collecting and storing devices are determined. Then mean values and nyctemeral cycles are measured both in normal subjects and patients with rheumatoid arthritis and other similar pathologies. Abnormal concentrations of Cu and Zn and anomalies in the nyctemeral cycle are found in the patients. In the second phase of the project, the special case of chrysotherapeutically treated (gold salt treatment) rheumatoid arthritis patients is studied for extended periods of time (up to 53 weeks). (orig.)

  16. Multivariate statistical analysis of major and trace element data for ...

    African Journals Online (AJOL)

    Multivariate statistical analysis of major and trace element data for niobium exploration in the peralkaline granites of the anorogenic ring-complex province of Nigeria. PO Ogunleye, EC Ike, I Garba. Abstract. No Abstract Available Journal of Mining and Geology Vol.40(2) 2004: 107-117. Full Text: EMAIL FULL TEXT EMAIL ...

  17. Trace elements in higher fungi (mushrooms) determined by activation analysis

    Czech Academy of Sciences Publication Activity Database

    Řanda, Zdeněk; Kučera, Jan

    2004-01-01

    Roč. 259, č. 1 (2004), s. 99-107 ISSN 0236-5731 R&D Projects: GA ČR GV202/97/K038 Institutional research plan: CEZ:AV0Z1048901 Keywords : trace elements * activation analysis * mushrooms Subject RIV: DN - Health Impact of the Environment Quality Impact factor: 0.457, year: 2004

  18. Analysis of Trace Elements in South African Clinkers using Latent ...

    African Journals Online (AJOL)

    The trace element content of clinkers (and possibly of cements) can be used to identify the manufacturing factory. The Mg, Sr, Ba, Mn, Ti, Zr, Zn and V content of clinkers give detailed information for the determination of the origin of clinkers produced in different factories. However, for the analysis of such complex data there ...

  19. Comparative pixe analysis of trace elements in archaeological samples

    Science.gov (United States)

    Zhang, Dazhong; Chen, Jianxuan; Chen, Suqing; Wang, Nengming

    1987-04-01

    Comparative analysis of trace elements in tomato seeds from the earlier Western Han dynasty (200 B.C.) tomb in suburban Chengdu and present tomato seeds in Chengdu Qingdao and Beijing has been performed. The intended purpose of this analysis is to provide some useful information for archaeologists and biologists to solve controversial problems involved in the place of origin of the ancient tomato seeds. In order to study the ancient agricultural technique, seed reservation and environment science, the trace elements in carbonized food and the wood of a coffin have also been analyzed. The experimental results demonstrate that there are significant differences between the elemental composition and relative contents of ancient tomato seeds. In this paper the analysis of trace elements in historic relics from the group tombs of the minority nationality in Aba Tibetan Autonomy State of Sichuan Province is also reported. It is found that in the glazed pearls there is much Ba and Pb which is significant for the study of glass manufacture techniques in ancient China All experiments were done in vacuum by nondestructive PIXE analysis using a 2.5 MV Van de Graaff accelerator and a Si(Li) spectrometer at the Institute of Nuclear Science and Technology of Sichuan University.

  20. Trace element analysis by PIXE in several biomedical fields

    Science.gov (United States)

    Weber, G.; Robaye, G.; Bartsch, P.; Collignon, A.; Beguin, Y.; Roelandts, I.; Delbrouck, J. M.

    1984-04-01

    Since 1980 in the University of Liége trace element analysis by PIXE has been developed in several directions, among these: the elemental composition of lung parenchyma, hilar lymph nodes, blood content in hematological disorders and renal insufficiency. The content in trace elements of lung tumor and surrounding tissue is measured and compared to similar content previously obtained on unselected patients of comparable ages. The normalization of the bromine deficiency observed in hemodialized patients is achieved by using a dialyzing bath doped with NaBr in order to obtain a normal bromine level of 5.7 μg/ml. The content of Cu, Zn, Br and Se in blood serum from more than 100 patients suffering from malignant hemopathy has been measured. The results are compared with a reference group. These oligoelements have also been measured sequentially for patients under intensive chemotherapy in acute myeloid leukemia.

  1. Elemental analysis of biological materials. Current problems and techniques with special reference to trace elements

    International Nuclear Information System (INIS)

    1980-01-01

    Selected techniques were reviewed for the assay of trace and minor elements in biological materials. Other relevant information is also presented on the need for such analyses, sampling, sample preparation and analytical quality control. In order to evaluate and compare the applicability of the various analytical techniques on a meaningful and objective basis, the materials chosen for consideration were intended to be typical of a wide range of biological matrics of different elemental compositions, namely Bowen's kale, representing a plant material, and NBS bovine liver, IAEA animal muscle, and blood serum, representing animal tissues. The subject is reviewed under the following headings: on the need for trace element analyses in the life sciences (4 papers); sampling and sample preparation for trace element analysis (2 papers); analytical techniques for trace and minor elements in biological materials (7 papers); analytical quality control (2 papers)

  2. PIXE analysis of caries related trace elements in tooth enamel

    International Nuclear Information System (INIS)

    Annegarn, H.J.; Jodaikin, A.; Cleaton-Jones, P.E.; Sellschop, J.P.F.; Madiba, C.C.P.; Bibby, D.; University of the Witwatersrand, Johannesburg

    1981-01-01

    PIXE analysis has been applied to a set of twenty human teeth to determine trace element concentration in enamel from areas suceptible to dental caries (mesial and distal contact points) and in areas less susceptible to the disease (buccal surface), with the aim of determining the possible roles of trace elements in the carious process. The samples were caries-free anterior incisors extracted for periodontal reasons from subjects 10-30 years of age. Prior to extraction of the sample teeth, a detailed dental history and examination was carried out in each individual. PIXE analysis, using a 3 MeV proton beam of 1 mm diameter, allowed the determination of Ca, Mn, Fe, Cu, Zn, Sr and Pb above detection limits. As demonstrated in this work, the enhanced sensitivity of PIXE analysis over electron microprobe analysis, and capability of localised surface analysis compared with the pooled samples require for neutron activation analysis, makes it a powerful and useful technique in dental analysis. (orig.)

  3. Chemical analysis of useful trace elements in sea water

    International Nuclear Information System (INIS)

    Katoh, Shunsaku; Fujii, Ayako; Miyai, Yoshitaka; Sakane, Kohji; Ogata, Noboru.

    1983-01-01

    The methods for the analysis of useful trace elements in sea water which have been tried so far are reviewed, and these methods are described briefly from the standpoint of studying the collection of resources. Ag and Au can be determined by concentrating sea water by ion-exchange method, solvent extraction method and electrodeposition method, then the elements are measured quantitatively by activation analysis and atomic absorption spectrochemical analysis. Sr, B and Li, which exist in relatively high concentration in sea water, are determined easily by atomic absorption spectrochemical analysis and absorption spectrometry. U, Mo and V are measured suitably by concentrating the elements by coprecipitation or solvent extraction method, and measuring by fluorescence analysis and arsenazo-3 method for U and through graphite-atomic absorption analysis for Mo and V. It has been revealed that the concentration of Ag and Au in sea water is extremely low, accordingly the recovery study is not conducted recently. On the other hand, the adsorption method using hydrated titanium oxide and amidoxim adsorbents for U, Mo and V, the adsorption method using aluminum adsorbent for Li, and the adsorption method using magnesium oxide and zirconium hydroxide and the solvent extraction method for B are hopeful to recover these elements. (Yoshitake, I.)

  4. PIXE analysis for bioaccumulation studies of trace elements

    International Nuclear Information System (INIS)

    Iwata, Y.; Satoh, A.; Sasaki, Y.; Ito, R.; Kuramachi, K.

    2005-01-01

    Bioaccumulation by micro-alga in the ocean was simulated in nutritive seawater containing known amounts of trace metals, and the concentration factors for Fe, Zn and Cd were measured by PIXE. Trace transition metals in nearshore seawater were removed by Chelex-100. Then a culture solution was prepared by adding known amounts of trace metals and nutritive salts to the purified seawater. Marine micro-algae (Nannochloropsis sp., and Phaeodactylum sp.,) were purely cultured in the culture solution. An interested metal ion was added to the culture solution (0.01-5.0 mg/l). Alga in 10 ml of the culture solution was collected on a polycarbonate filter (pore size: 1.0 ) by suction filtration and subjected to 2.9 MeV proton bombardment. Na, Mg, Al, Si, P, S, Cl, K, Ca, Cr, Mn, Fe, Zn and Cd were simultaneously determined. PIXE multi-element analysis was possible using less than 1 mg of analytical sample. The quantity of the metal in the alga was increased in proportion to the concentration in the culture solution. The concentration factors for Zn, Fe and Cd were measured, e.g., 10200 ± 300 ml/g to Zn for Phaeodactylum. The trend of the affinity for the trace metals in the case of Nannochloropsis was Fe 3+ > Zn 2+ > Pb 2+ > Cd 2+ . (author)

  5. Nuclear reaction analysis (NRA) for trace element detection

    Energy Technology Data Exchange (ETDEWEB)

    Doebeli, M. [Paul Scherrer Inst. (PSI), Villigen (Switzerland); Noll, K. [Bern Univ. (Switzerland)

    1997-09-01

    Ion beam induced nuclear reactions can be used to analyse trace element concentrations in materials. The method is especially suited for the detection of light contaminants in heavy matrices. (author) 3 figs., 2 refs.

  6. Medical and health-related trace element analysis by TXRF

    International Nuclear Information System (INIS)

    Greaves, E.D.

    2000-01-01

    The advantages offered with TXRF analysis by direct irradiation with monochromatic X-rays of tissue homogenates and body fluids make the technique appropriate for a number of medical and health related applications. The ability to detect low levels of toxic heavy elements is being used as an aid in accidental poisoning diagnosis and treatment, in treatment-induced toxicity control and as an accessory in medical and health research. Thus lead-in-whole-blood analysis is used in confirmation of diagnosis of victims of poisoning, or monitoring the evolution and efficiency of the clinical treatment. Measurement and control of plasma platinum levels of cancer patients undergoing chemotherapy with Pt-containing drugs includes: establishment of the drug level-tumor remission response, measurement of Pt plasma level curves and establishment of optimum dosage to minimize the nephrotoxicity of platinum, and bioequivalence comparisons of different commercially available platinum containing anticancer drugs. Analysis as an aid in clinical research applications includes: trace element determination of amniotic fluid in fetus malformation studies; analysis of brain specimens and cerebrospinal fluid in diagnosis of central nervous system disorders; the influence of trace elements in cataract genesis and the influence of heavy elements in semen quality in human reproduction studies. Human body samples require the use of monochromatized beams of x-rays in order to derive the special advantage of its use: i) The reduction in the spectrum background allowing direct irradiation of organic matter specimens. Hence human tissue and body fluids are prepared by simple procedures involving dilution, homogenization and standard addition avoiding the need for specimen digestion. This results in faster, cheaper methods that decrease sample contamination problems. ii) The presence of a large Compton scattered signal in the spectrum and its use as an internal standard reference allows further

  7. Trace element analysis in silicon by accelerator SIMS

    Energy Technology Data Exchange (ETDEWEB)

    Ender, R.M.; Suter, M. [Eidgenoessische Technische Hochschule, Zurich (Switzerland); Doebeli, M.; Synal, H.A. [Paul Scherrer Inst. (PSI), Villigen (Switzerland)

    1997-09-01

    The accelerator SIMS technique has been applied to Si samples implanted with different elements. It has been shown that concentrations of several trace elements can be analysed down to about 1 ppb in depth profiling mode. (author) 2 figs., 1 ref.

  8. Neutron activation analysis of trace elements in sea water samples

    International Nuclear Information System (INIS)

    Kusaka, Yuzuru; Tsuji, Haruo; Imai, Sakingo; Ohmori, Sayoko.

    1979-01-01

    Analytical values of trace elements in sea water samples have been fluctuated according to the sampling locations, the analytical procedures and so on. It is very important in marine chemistry to elucidate the cause of such concentration variations. This report is the analytical results of the samples obtained in the Pacific Ocean, the Indian Ocean and the Sea of Japan, by means of neutron activation analysis. As the preconcentration, 1-pyrrolidine carbothio acid (APDC)-chelate extraction and freeze-drying were adopted. The specimens obtained by this extraction from 500 or 800 ml samples were irradiated by KUR reactor for 1 min, 1 hr to 10 hrs and the gamma-ray spectrometry with a Ge(Li) detector was used for the determination of V, Mn, Cu, Zn, U, Fe, Co, Ni, Ag, Sb and Au. By about 80 hrs irradiation of the specimens obtained by freeze-drying from 20 ml samples and their gamma-ray spectrometry, Sc, Cr, Fe, Co, Zn, Rb, Sr, Ag, Sb and Cs were determined. The former procedure gives concentrations of elements in species reactable with APDC, but the latter method shows entire concentrations of the elements in the sea water samples. Some considerations on the analytical values and the comparisons of the both methods are described. (author)

  9. Optical selection of trace elements for discriminant analysis

    International Nuclear Information System (INIS)

    Rasmussen, S.E.; Erasmus, C.S.; Watterson, J.I.W.; Sellschop, J.P.F.

    This report describes different methods of element selection; a combination of stepwise multivariate analysis of variance for primary element selection, and principle component analysis regression for the element interrelationship analysis. These offer a satisfactory solution to the problem of element selection

  10. X-ray trace element analysis with positive ion beams

    International Nuclear Information System (INIS)

    Davis, R.H.

    1973-01-01

    A new trace element analysis having the advantage that many elements may be detected in a single measurement, based on positive charged particle induced X-ray florescence and on the production of X-rays by heavy ions, is described. Because of the large cross-sections for the production of discrete X-ray and the low yield of continuum radiation, positive charged particle X-ray florescence is a competitive, fast, analytic tool. In the experiment a beam of positive charged particles from an accelerator was directed toward a target. X-rays induced by the bombardment were detected by a Si(Li) detector the ouput from which was amplified and sorted in a multichannel analyzer. For rapid data handling and analysis, the multichannel analyzer or ADC unit was connected to an on-line computer. A large variety of targets prepared in collaboration with the oceanographers have been studied and spectra obtained for different particles having the same velocity are presented to show that the yield of discrete X-rays increases at least as rapidly as Z 2 . While protons of several MeV appear to be already competitive further advantage may be gained by heavy ions at lower energies since the continuum is reduced while the peak ''signals'' retain strength due to the Z 2 dependence. (S.B.)

  11. Neutron activation analysis of trace elements in Japanese hormesis cosmetics

    International Nuclear Information System (INIS)

    Furuta, E.; Nakahara, H.; Hatsukawa, Y.; Matsue, H.; Sakane, H.

    2008-01-01

    In Japan, cosmetics claiming hormesis effect are available through Internet. Although these cosmetics show the contents, they never mention the minor elements and radioactive sources. The existence of radioisotopes, however, was observed by measurements of the gamma-rays with a HPGe detector. In this study, in order to clarify the contents of trace elements, the hormesis cosmetics including radioactive sources were analyzed using INAA, PGAA and NAA with multiple gamma-ray detection (NAAMG). Nineteen elements were analyzed quantitatively in hormesis cosmetics by INAA, PGAA and NAAMG and 16 elements were detected qualitatively by SEM-EPMA. (author)

  12. PIXE analysis of trace elements in Genus Hippophae L

    International Nuclear Information System (INIS)

    Yin Zhongli; Jiang Xiangzhou; Ma Chengjun; Hao Jifang

    1993-01-01

    Trace elements in four kinds of the Genus Hippophae L pulps were analysed by PIXE. Optimization of the system performance was done by carefully selecting the absorbers. Analytical sensitivities of the PIXE system were obtained by means of 'external standard method'

  13. Analysis of Trace Elements in South African Clinkers using Latent ...

    African Journals Online (AJOL)

    Application of two-dimensional probabilistic PCA, and hierarchical clustering of the latent variables. 4.1. Model 1. The clustering algorithm is sensitive to variations in the numerical ranges of different features. Hence, the obtained clusters can be negatively influenced by the different magnitude of the trace element contents.

  14. Neutron activation analysis of trace elements in foodstuffs

    International Nuclear Information System (INIS)

    Schelenz, R.; Bayat, I.; Fischer, E.

    1976-05-01

    For the determination of trace elements in foodstuffs with the aid of neutron activation analysis the separation of volatile radionuclides after digestion of the sample is of special interest for radiochemical processing. A distillation procedure was developed to give reproducable results, however optimal conditions were not found for all volatile radionuclides studied. The required selective separation of Br-82 from the distillate was best achieved by the application of an ion-exchange column-chromatography technique. The computer programs for the evaluation of complex gamma spectra have been developed further. The automatic peak search and peak area determination is based on a computer program using the correlation technique and carried out with a mini-computer coupled with a multi-channel gamma spectrometer. The results, which are presented in 3 earlier reports relating to this research program, reveal the advantages and disadvantages of the individual steps of the radiochemical separation scheme. Before neutron activation analysis can be introduced on a routine basis, some aspects of the radiochemical process remain to be tested; these studies will be published in a fourth and final report. (orig.) [de

  15. [Analysis of trace elements in limestone for archeological functions

    Energy Technology Data Exchange (ETDEWEB)

    Blanc, A. [Lab. de Recherche des Monuments Historiques, Champs-sur-Marne (France); Holmes, L.; Harbottle, G. [Brookhaven National Lab., Upton, NY (US). Chemistry Dept.

    1998-12-31

    Numerous quarries in the Lutetian limestone formations of the Paris Basin provided stone for the building and the decoration of monuments from antiquity to the present. To determine the origin of stone used for masonry and sculptures in these monuments, a team of geologists and archaeologists has investigated 300 quarries and collected 2,300 samples. Petrographic and paleontologic examination of thin sections allows geologists to distinguish Lutetian limestones from Jurassic and Cretaceous limestones. Geologists also seek to formulate hypotheses regarding the origin of Lutetian limestones used for building and sculpture in the Paris region. In the search for the sources of building and sculptural stone, the analytical methods of geologists are limited because often several quarries produce the same lithofacies. A new tool is now available, however, to attack questions of provenance raised by art historians. Because limestones from different sources have distinctive patterns of trace-element concentrations, compositional analysis by neutron activation allows one to compare building or sculptural stone from one monument with stone from quarries or other monuments. This analytical method subjects a powdered limestone sample to standard neutron activation analysis procedures at Brookhaven National Laboratory. With the help of computer programs, the compositional fingerprints of Lutetian limestones can be determined and stored in a database. The limestone database contains data for approximately 2,100 samples from monuments, sculptures and quarries. It is particularly rich in samples from the Paris Basin.

  16. [Determination and correlation analysis of trace elements in Boletus tomentipes].

    Science.gov (United States)

    Li, Tao; Wang, Yuan-zhong; Zhang, Ji; Zhao, Yan-li; Liu, Hong-gao

    2011-07-01

    The contents of eleven trace elements in Boletus tomentipes were determined by inductively coupled plasma atomic emission spectroscopy (ICP-AES). The results showed that the fruiting bodies of B. tomentipes were very rich in Mg and Fe (>100 mg x kg(-1)) and rich in Mn, Zn and Cu (>10 mg x kg(-1)). Cr, Pb, Ni, Cd, and As were relatively minor contents (0.1-10.0 mg x kg(-1)) of this species, while Hg occurred at the smallest content (< 0.1 mg x kg(-1)). Among the determined 11 trace elements, Zn-Cu had significantly positive correlation (r = 0.659, P < 0.05), whereas, Hg-As, Ni-Fe, and Zn-Mg had significantly negative correlation (r = -0.672, -0.610, -0.617, P < 0.05). This paper presented the trace elements properties of B. tomentipes, and is expected to be useful for exploitation and quality evaluation of this species.

  17. Storage and pre-neutron-activation-analysis treatment for trace-element analysis in urine

    International Nuclear Information System (INIS)

    Blotcky, A.J.; Rack, E.P.

    1985-01-01

    The problems regarding storage and pre-neutron-activation-analysis treatment for the elements aluminum, calcium, vanadium, selenium, copper, iodine, zinc, manganese, and magnesium in a urine matrix are reviewed. The type of collection and storage procedure and pre-neutron activation analysis treatment of urine depend on the specific trace element; that is, its inherent physical and chemical properties. Specifically polyethylene in teflon containers are the most suitable for general determinations. Whether any preservative is added would depend upon the stability of the trace element and its tendency for surface adsorption. Preferably, preservatives should contain no radioactivatable elements for maximum efficacy. Freeze drying or packing urine shipments under dry ice needs to be explored on an individual basis. Each pre- or post-neutron activation analysis treatment is specific and optimized for the trace element analyzed

  18. The analysis of trace elements in new superconducting materials

    International Nuclear Information System (INIS)

    Comtois, R.R.

    1988-01-01

    Dramatic advances in the engineering and performance of the new superconducting oxides have lead to the need for in depth material characterization. Although physical measurements have been the rule by which improvements have been measured it is imperative that studies be conducted to obtain information on the chemical makeup and structure of each superconducting test sample. This data is key to establishing a basis for the next stage of development. Recent technological innovation in the developmental engineering of Zeeman-corrected, graphite furnace atomic absorption spectrophotometry has resulted in an instrument that is capable of directly determining trace elements in solid material. The Grun SM-20 has been tested for its applicability to the direct determination of six trace elements in SC materials. The ability to achieve accurate results in total methodology time of several minutes will be discussed, as well as performance figures of merit and problems encountered. Recommended future developments and further areas of study resulting from this study are also covered

  19. Environmental trace-element analysis using a benchtop total reflection X-ray fluorescence spectrometer.

    Science.gov (United States)

    Stosnach, Hagen

    2005-07-01

    Total reflection X-ray fluorescence (TXRF) analysis is an established technique for trace-element analysis in various types of samples. Though expensive large-scale systems restricted the applications in the past, in this study the capability of a benchtop system for trace elemental analysis is reported. The suitability of this system for the mobile on-site analysis of heavy metal contaminated soils and sediments is reported as well as the possibilities and restrictions of TXRF for additional applications, including trace-element analysis of water, glass and biological samples.

  20. Multi-element analysis of mineral and trace elements in medicinal herbs and their infusions.

    Science.gov (United States)

    Pytlakowska, K; Kita, A; Janoska, P; Połowniak, M; Kozik, V

    2012-11-15

    Twelve mineral and trace elements (Al, B, Ba, Fe, Zn, Mn, Mg, K, Na, P, Cu, Sr, and Ca) were determined in the herbs and their infusions consumed for medical purposes in Poland such as chamomile (Matricaria chamomilla L.), peppermint (Mentha xpiperita), melissa (Melissa officinalis), sage (Salvia officinalis), nettle (Urtica dioica), linden (Tilia vulgaris) and St. John's wort (Hypericum calycinum). Dry digestion procedure for total concentration and wet digestion procedure for infusions were applied under optimized conditions for dissolution of medicinal herbs. Element concentrations in herbs and their infusions were determined by ICP-OES. The accuracy and precision were verified against NCS DC 73349 - bush branches and leaves certified reference material. The result of total concentrations of elements in herb leaves shows that all herbs contain most of the elements, except K and P, in the μg/g range, and that elemental concentrations varied widely. Moreover, on the basis of experimental results for the extraction efficiencies, the elements in herb infusions were classified into three specific groups: highly-extractable (>55%) including K; moderately-extractable (20-55%) including Mg, Na, P, B, Zn and Cu and poorly-extractable (<20%) including Al, Fe, Mn, Ba, Ca and Sr. The results of analysis were evaluated statistically using ANOVA one-way and three-way analysis of variance, variance correlation test and Spearman's test. Copyright © 2012 Elsevier Ltd. All rights reserved.

  1. Trace element evaluation of different varieties of chewing gum by radiochemical neutron activation analysis

    International Nuclear Information System (INIS)

    Zaidi, J.H.; Arif, M.; Fatima, I.; Ahmad, S.; Qureshi, I.H.

    2000-01-01

    Extensive use of chewing gums, by children in particular, entails the evaluation of trace element contents in them. Radiochemical neutron activation analysis (RNAA) was successfully employed to determine the concentration of 35 trace elements (essential, toxic and nonessential) in eight different brands of chewing gum generally consumed in Rawalpindi/Islamabad area. Comparison of trace element data of our work with literature has been presented. None of the elements detected in the brands of chewing gum examined was found to be present at a level representing a substantial contribution to the total dietary intake of the element. (author)

  2. Concentration of 24 Trace Elements in Human Heart Tissue Determined by Neutron Activation Analysis

    International Nuclear Information System (INIS)

    Wester, P.O.

    1964-06-01

    By means of neutron-activation analysis, human heart tissue from autopsy of 20 victims of traumatic accidents has been investigated with respect to the concentration of 24 different trace elements. A recently developed ion-exchange technique combined with gamma spectrometry has been used, which permits simultaneous determination of a large number of trace elements. The following trace elements have been determined quantitatively: Ag, As, Au, Ba, Br; Ca, Cd, Ce, Co, Cr, Cs, Cu, Fe, Hg, La, Mo, Pt, Rb, Sb, Se, Se, Sm, Zn, W. In some heart samples, Hf and Os were determined qualitatively. The mean and standard deviation are given for the elements Cu, Fe, Se and Zn, Since none of the other quantitatively determined trace elements were normally distributed, the median is given as the central value. When possible, comparisons with values from other investigations have been made. No marked differences in the trace-element concentrations with age or sex could be detected

  3. Assurance and control of quality in trace element analysis

    International Nuclear Information System (INIS)

    Heinonen, J.

    1979-01-01

    The study demonstrates in practice the assurance and control of the quality of results from trace analysis in biological materials. The performance of three analytical methods is studied: one involving the determination of Cs and two the determination of As by neutron activation techniques in biological materials at the natural background level. In the case of Cs, the validity of the analytical procedure was investigated by the means available in the laboratory of the Institute and by utilizing the specific properties of the determinant. In the establishment and control of accuracy, the analysis of precision was essential. The investigation of the two different methods applied for the determination of arsenic demonstrates the many problems connected with trace analysis. For the control of accuracy a number of different kinds of reference materials (RMs) were used, namely four former intercomparison materials of the IAEA and two certified RMs of the NBS. The various tests performed revealed two different types of systematic errors. The scheme applied for the long-term surveillance of systematic and random errors is found to be suitable for the continuous control of quality of results from routine analysis. (author)

  4. Biomonitoring of air pollution through trace element analysis

    International Nuclear Information System (INIS)

    Bamford, S.A.; Osae, E.K.; Aboh, I. J.; Serfor-Armah, Y.; Nyarko, B.; Ofosu, F.; Odamtten, G.T.

    1999-04-01

    Studies are being carried out to determine the potential and reliability in the use of local lichen species for biomonitoring air pollution in Ghana. The location of most of the gold mines in forest areas of the country presents the gold mining industry as a suitable setting for such investigations. The nuclear-related techniques being used in the multielement analysis of lichen samples and air filter samples are instrumental neutron activation analysis (Miniature Neutron Source Reactor) and energy dispersive x-ray fluorescence analysis (tube-excitation). Validation of the quantitative methods of the INAA through analysis of standard certified reference materials of orchard leaves NBS SRM 1571 and BCR-CRM No. 279 gave very good results for most elements analyzed. Elemental analysis of identified lichen samples will be done bearing in mind microclimatic factors, specie type and nature of soil. (author)

  5. Biomonitoring of air pollution through trace element analysis

    International Nuclear Information System (INIS)

    Bamford, S.A.; Osae, E.K.; Aboh, I.J.; Serfor-Armah, Y.; Nyarko, B.; Odamtten, G.T.

    1999-01-01

    Studies are being carried out to determine the potential and reliability in the use of local lichen species for biomonitoring air pollution in Ghana. The location of most of the gold mines in forest areas of the country presents the gold mining industry as a suitable setting for such investigations. The nuclear-related techniques being used in the multielement analysis of lichen samples and air filter samples are instrumental neutron activation analysis (Miniature Neutron Source Reactor) and energy dispersive x-ray fluorescence analysis (tube-excitation). Validation of the quantitative methods of the INAA through analysis of standard and certified reference materials of orchard leaves NBS SRM 1571 and BCR-CRM No. 279 gave very good results for most elements analyzed. Elemental analysis of identified lichen samples will be done beating in mind microclimatic factors, specie type and nature of soil. (author)

  6. Multivariate cluster analysis of some major and trace elements ...

    African Journals Online (AJOL)

    UFUOMA

    This study comprises soils formed on Paleoproterozoic Birimian Basement rocks (poorly graded silty sand, gravely sand and silty clays) from the unsaturated zone of the Densu River Basin, taken from a five meter depth. Elemental analysis of the soils samples were carried out by Energy Dispersive X-ray. Fluorescence ...

  7. Neutron activation analysis as applied to instrumental analysis of trace elements from seawater

    International Nuclear Information System (INIS)

    Boniforti, R.; Moauro, A.; Madaro, M.

    1983-01-01

    Particulate matter collected from the coastal area delimited by the mouth of the river Volturno and the Sabaudia lake has been analyzed by instrumental neutron activation analysis for its content of twenty-two trace elements. The results for surface water and bottom water are reported separately, thus evidencing the effect of sampling depth on the concentration of many elements. The necessity of accurately 'cleaning' the filters before use is stressed

  8. Instrumental neutron activation analysis in environmental studies of trace elements

    International Nuclear Information System (INIS)

    Salmon, L.

    1975-06-01

    The application of a routine instrumental nuclear method is described in relation to environmental surveys and studies. A working rather than formal review is made of the techniques applied with particular reference to the data processing methods involved. The elements measured by instrumental activation analysis were: Ag, Al, As, Au, Ba, Br, Ca, Ce, Cl, Cd, Co, Cr, Cs, Cu, Fe, Hg, I, In, La, Mn, Na, Ni, Pb, Rb, Sb, Sc, Se, Th, Ti, U, V, W, Zn. (author)

  9. Particle induced X-ray emission for quantitative trace-element analysis using the Eindhoven cyclotron

    International Nuclear Information System (INIS)

    Kivits, H.

    1980-01-01

    Development of a multi-elemental trace analysis technique using PIXE (Particle Induced X-ray Emission), was started almost five years ago at the Eindhoven University of Technology, in the Cyclotron Applications Group of the Physics Department. The aim of the work presented is to improve the quantitative aspects of trace-element analysis with PIXE, as well as versatility, speed and simplicity. (Auth.)

  10. [Analysis of trace elements in chrysanthemum from different habitats with ICP-MS].

    Science.gov (United States)

    Nie, Jiu-Sheng; Zhai, Hong-Yan; Wu, De-Ling; Zhang, Ya-Zhong; Fang, Cheng-Wu; Yu, Nian-Jun

    2013-03-01

    To establish a method for determination of trace elements in chrysanthemum and analyze trace elements in chrysanthemum from different habitats. The preprocessing for determination of trace elements in chrysanthemum was carried out by microwave digestion,the content of trace elements in chrysanthemum was determined by ICP-MS. The content of trace elements of chryscmthemum varied with the habitats. The contents of trace elements as well as heavy metals of Chrysanthemum relate to its species and habitats to a certain degree.

  11. Neutron activation analysis of traces of metallic elements in water

    International Nuclear Information System (INIS)

    Pinte, G.; Lefol, N.; May, S.; Darras, R.

    1975-01-01

    The application of neutron activation analysis is examined for the elements iron, nickel, chromium and cobalt which are constituents of the aqueous corrosion products of stainless steels and which are present in very low concentrations in the water used in the heat transfer systems of nuclear reactors. The best results were obtained by slow evaporation of the water sample in a quartz ampoule in an oven followed by irradiation of the dry sample in the same ampoule. The problems of blanks, of losses during concentration, and of conservation of solutions at very low concentrations were studied. Good agreement was found between the theoretical quantities and experimental results with standard samples containing 50ppb of each of the studied elements. There was also excellent agreement between neutron activation and spectrophotometric methods in the case of determinations of iron in solution [fr

  12. Trace element determination in beauty products by k0-instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Sneyers, L.; Verheyen, L.; Vermaercke, P.; Bruggeman, M.

    2009-01-01

    A recent study on trace elements in beauty products and cosmetics sold on the Asian market has shown the presence of high levels of U, Th and rare earth elements in so called 'Hormesis cosmetics'. For the purpose of comparison, some more information about trace elements in European cosmetics would be useful. In this paper the results obtained using k 0 -standardised Instrumental Neutron Activation Analysis (k 0 -INAA) for more than 20 trace elements in 20 different beauty products collected from the European market are presented. We found traces of Ba, As and Sb which is in breach with European legislation. For some of the other elements like Cr and Co further speciation is needed in order to evaluate their presence in beauty products. (author)

  13. Trace elements and human fertility.

    OpenAIRE

    Stovell, Alex Gordon.

    1999-01-01

    Methods were developed and validated for the analysis of trace elements in human scalp hair, blood serum, ovarian follicular fluid and seminal plasma by inductively coupled plasma mass spectrometry (ICP-MS). An interlaboratory comparison was also undertaken to compare the analysis of biological materials by ICP-MS with instrumental neutron activation analysis (INAA). Preliminary trace element protein speciation experiments were carried out using size exclusion high performance liquid chromato...

  14. Biomonitoring of air pollution through trace element analysis

    International Nuclear Information System (INIS)

    Akoto Bamford, Samuel; Osae, E.K.; Serfor-Armah, Y.; Nyarko, B.; Ofosu, F.; Aboh, I.J.; Odamtten, G.T.

    2001-01-01

    Research work is currently going on to determine the suitability in the use of local lichen species for biomonitoring air pollution in Ghana. The study areas being investigated are the gold-mining areas situated in the Moist Evergreen and Semi-Deciduous forests in Ghana. The nuclear analytical techniques being used in this work are instrumental neutron activation analysis and tube-excited x-ray fluorescence spectrometry. The present report covers results of quality control exercise carried out to validate the quantitative methods being used. This includes our participation in an intercomparison exercise carried out among participants of the IAEA coordinated research project. The samples analyzed were two lichen samples from two completely different areas using neutron activation analysis. Only short- and medium-lived irradiations were carried out. Satisfactory results were obtained for most of the elements identified and quantified. (author)

  15. Preparation steps in environmental trace element analysis - facts and traps.

    Science.gov (United States)

    Hoenig, M

    2001-07-06

    The laboratory of CERVA is for several decades involved in the Belgian environmental research. The activity was associated to national monitoring programs dealing with trace metal pollution of all compartments of the environment (sea and river waters, sediments and organisms but also soils, plants, animal and food samples). Such a monitoring dealing with the total analyte contents in samples needed a comprehensive development of the whole methodology associated to the analyses using atomic absorption and emission spectroscopy techniques. This includes measurement but also preparation steps. The latter is the subject of this work. Long-term experience has shown that precisely sample preparation is the most critical part of the analysis because it is responsible for the largest and often hidden sources of errors. Errors due to contaminations may be usually overcome if necessary precautions are taken concerning reagents, tools and the manner of working. The problem is different for analyte losses: in this case, the responsible factor is an inappropriate methodology. This is particularly true for preparation of solid samples that have to be brought in a solution in order to satisfy needs of introduction systems of most spectroscopic techniques utilized in routine laboratories. For some types of samples (e.g. animal tissues), the dissolution is not a problem: it may be readily achieved by several procedures. This is not the case for samples that contain silicates in their matrix (e.g. soils, sediments, plants) because their complete dissolution cannot be ensured by a simple procedure. This review describes the present knowledge regarding possibilities and errors that concern preparation steps. In addition, possible effects of the preparation procedure on the quality of measurement are also systematically discussed.

  16. Speciation of trace elements in river water utilizing activation analysis and size fractionation methods

    Energy Technology Data Exchange (ETDEWEB)

    Tanizaki, Yoshiyuki [Tokyo Metropolitan Isotope Research Center (Japan)

    1994-07-01

    It is significant to elucidate the forms of existence of trace elements in natural water for knowing the physical and chemical behaviors of respective elements in hydrosphere, and evaluating the usefulness or toxicity for living bodies. But it is very difficult to analyze directly the chemical forms of many trace elements by ordinary chemical techniques. The authors pay attention to the fact that the particle size of the trace elements in natural water is different according to their forms of existence, and have carried out the examination of a simple and convenient form analysis method `Particle size fractionation method`. This is to fractionate the trace elements in natural water, classifying them by particle size using the millipore filters and ultrafilters having various pore diameter, and to presume the forms of existence according to the state of particle size distribution of respective elements. The information on chemical forms cannot be obtained by this method, therefore, the irradiation of sample water with gamma ray is carried out. Gamma ray irradiation treatment, particle size fractionation treatment, activation analysis, the form classification method for trace elements, and the results of fractionation of respective elements are reported. (K.I.).

  17. Trace element analysis of soil type collected from the Manjung and central Perak

    Energy Technology Data Exchange (ETDEWEB)

    Azman, Muhammad Azfar, E-mail: m-azfar@nuclearmalaysia.gov.my; Hamzah, Suhaimi; Rahman, Shamsiah Abdul; Elias, Md Suhaimi; Abdullah, Nazaratul Ashifa; Hashim, Azian; Shukor, Shakirah Abd; Kamaruddin, Ahmad Hasnulhadi Che [Blok 18, Makmal Analisis Kimia (Aca/Bas), Agensi Nuklear Malaysia, 43000 Kajang, Selangor (Malaysia)

    2015-04-29

    Trace elements in soils primarily originated from their parent materials. Parents’ material is the underlying geological material that has been undergone different types of chemical weathering and leaching processes. Soil trace elements concentrations may be increases as a result of continuous input from various human activities, including power generation, agriculture, mining and manufacturing. This paper describes the Neutron Activation Analysis (NAA) method used for the determination of trace elements concentrations in part per million (ppm) present in the terrestrial environment soil in Perak. The data may indicate any contamination of trace elements contributed from human activities in the area. The enrichment factors were used to check if there any contamination due to the human activities (power plants, agricultural, mining, etc.) otherwise the values would serve as a baseline data for future study. The samples were collected from 27 locations of different soil series in the area at two different depths: the top soil (0-15cm) and the sub soil (15-30cm). The collected soil samples were air dried at 60°C and passed through 2 µm sieve. Instrumental Neutron Activation Analysis (NAA) has been used for the determination of trace elements. Samples were activated in the Nuclear Malaysia TRIGA Mark II reactor followed by gamma spectrometric analysis. By activating the stable elements in the samples, the elements can be determined from the intensities of gamma energies emitted by the respected radionuclides.

  18. Application of micro-PIXE analysis to investigate trace elements in deciduous teeth enamel

    International Nuclear Information System (INIS)

    Igari, K.; Takahashi, A.; Ando, H.

    2010-01-01

    The early life environment has widespread consequences for later health and disease. To prevent the disease in later life, the assessment of fetal environment is very important. In Japan, birthweight has fallen rapidly during recent two decades. The reduction of birthweight represents reduced fetal nutrition. Deciduous tooth enamel contains pre- and postnatal enamel and its chemical composition reflects the status of metabolism of trace elements during formation period. Deciduous tooth enamel is considered to be a suitable indicator of trace elements exposure in utero. We applied micro-PIXE analysis to investigate the trace elemental content in deciduous tooth enamel. Two deciduous canines from one healthy Japanese boy were used for this study. The enamel section including pre- and postnatal enamel was prepared for micro-PIXE analysis. Five trace elements (Na, Mg, Cl, Zn, and Sr) were detected in the scanning area of tooth. The distribution profiles of 5 elements were obtained as X-ray maps. The distribution profiles of zinc and chlorine were specific, and showed higher concentration in surface enamel. No elements showed different profiles of X-ray maps between pre- and postnatal enamel in this sample. The results of this study suggested that micro-PIXE analysis would be able to estimate the trace elements in prenatal and postnatal enamel, respectively. (author)

  19. Trace elements in Turkish tobacco determined by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Guelovali, M.C.; Guenduez, G.

    1983-01-01

    The concentration of 20 trace elements in nine brands of Turkish cigarette tobacco and in a brand of pipe tobacco ash has been determined by instrumental neutron activation analysis. The percent transference of elements into smoke has been estimated from the amounts remaining in the ash. (author)

  20. [Distribution Characteristics and Source Analysis of Dustfall Trace Elements During Winter in Beijing].

    Science.gov (United States)

    Xiong, Qiu-lin; Zhao, Wen-ji; Guo, Xiao-yu; Chen, Fan-tao; Shu, Tong-tong; Zheng, Xiao-xia; Zhao, Wen-hui

    2015-08-01

    The dustfall content is one of the evaluation indexes of atmospheric pollution. Trace elements especially heavy metals in dustfall can lead to risks to ecological environment and human health. In order to study the distribution characteristics of trace elements, heavy metals pollution and their sources in winter atmospheric dust, 49 dustfall samples were collected in Beijing City and nearby during November 2013 to March 2014. Then the contents (mass percentages) of 40 trace elements were measured by Elan DRC It type inductively coupled plasma mass (ICP-MS). Test results showed that more than half of the trace elements in the dust were less than 10 mg x kg(-1); about a quarter were between 10-100 mg x kg-1); while 7 elements (Pb, Zr, Cr, Cu, Zn, Sr and Ba) were more than 100 mg x kg(-1). The contents of Pb, Cu, Zn, Bi, Cd and Mo of winter dustfall in Beijing city.were respectively 4.18, 4.66, 5.35, 6.31, 6.62, and 8.62 times as high as those of corresponding elements in the surface soil in the same period, which went beyond the soil background values by more than 300% . The contribution of human activities to dustfall trace heavy metals content in Beijing city was larger than that in the surrounding region. Then sources analysis of dustfall and its 20 main trace elements (Cd, Mo, Nb, Ga, Co, Y, Nd, Li, La, Ni, Rb, V, Ce, Pb, Zr, Cr, Cu, Zn, Sr, Ba) was conducted through a multi-method analysis, including Pearson correlation analysis, Kendall correlation coefficient analysis and principal component analysis. Research results indicated that sources of winter dustfall in Beijing city were mainly composed of the earth's crust sources (including road dust, construction dust and remote transmission of dust) and the burning of fossil fuels (vehicle emissions, coal combustion, biomass combustion and industrial processes).

  1. Determination of trace elements in chewing gum by neutron activation analysis

    International Nuclear Information System (INIS)

    Dietz, M.L.

    1990-01-01

    Six trace elements of nutritional or toxicological interest (Al, Ca, Cl, Mn, Na and Sr) were determined in three different brands of chewing gum by instrumental neutron activation analysis. For the particular brands of gum examined, none of the detected elements was found to be present at a level representing a substantial contribution to the total dietary intake of the element for an American adult. (author) 11 refs.; 3 tabs

  2. Application of the neutron activation analysis method for determing trace elements in Brazilian food sample

    International Nuclear Information System (INIS)

    Maihara, V.A.; Vasconcellos, M.B.A.

    1988-01-01

    Recently there has been an increase of consciousness about the importance of trace elements in human health and disease as well as rising concern about food contamination. The development of sensitive, accurate and price methods is one of the most important of the knowledge of trace elements contents in foods and in biological samples. Neutron activation analysis is one of the most suitable tecniques because a great number of elements can be determined in concentrations in the range of μg/g to ng/g. The present work is a part of an AIEA Co-ordinated Research Programme on the applications of nuclear techniques for toxic elements in foodstuffs. Neutron activation analysis is applied to analysis of bread, milk powder and rice that are considered essential foods in the Brazilian diet. Some aspects of the activation analysis of biological matrices are discussed. (author) [pt

  3. Trace elements in adolescents

    OpenAIRE

    Barany, Ebba

    2002-01-01

    The major aim of the thesis was to monitor toxic and essential trace elements in a cohort of adolescents by blood and serum analyses, and describe the impact of different factors on the element concentrations. The adolescents were from the Swedish cities Uppsala and Trollhättan which represent different socioeconomic and environmental conditions, and were investigated at age 15 and 17. It was shown that an inductively coupled plasma mass spectrometry method was suitable for simultaneous deter...

  4. Accurate and precise major and trace element determination in marine samples by neutron activation analysis

    International Nuclear Information System (INIS)

    Sucgang, Raymond J.; Cao Dong Vu; Tran Quang Thien; Ho Van Doanh; Shirai, Naoki; Ebihara, Mitsuru

    2014-01-01

    The determination of elemental composition of marine samples has attracted a great deal of attention in environmental investigations,despite the obscurities presented by extremely low trace element concentrations and high calcium, sodium, and chloride interferences in those matrices. In this study, the expediency of instrumental neutron activation analysis, INAA, to measure major and trace elements in white sand, fish tissue, coral, and algae samples was evaluated. Sample irradiation was done at the IVV-9 nuclear research reactor in Dalat, Vietnam, using a fuel of WWR-M2, LEU (19.75% 2 '3 5 U), and neutron flux of 4.2x10 12 n/cm 2 /s for both short and long irradiation. Counts were determined using high purity coaxial type germanium detector, and quantified by K-zero method. The accuracy of the method was validated by a concurrent analyses of standard reference materials, NIST SRM 1646a (estuarine sediment) and NIST SRM 1400 (bone ash). No significant matrix effects were observed and the obtained results were in good agreement with certified values (accuracy of 5-15%). The less elaborate sample preparation in INAA compared to other wet techniques of trace element analysis has been shown to produce lesser risk of ultra trace element contamination and losses. Detection limits in the order of parts per billion, ppb, range can be reached. The relative standard deviations for most elements were found to be about or below zero, indicating good reproducibility. (author)

  5. Trace elements detection in whole food samples by Neutron Activation Analysis, k{sub 0}-method

    Energy Technology Data Exchange (ETDEWEB)

    Sathler, Márcia Maia; Menezes, Maria Ângela de Barros Correia, E-mail: maia.sathler@gmail.com, E-mail: menezes@cdtn.br [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil); Salles, Paula Maria Borges de, E-mail: pauladesalles@yahoo.com.br [Universidade Federal de Minas Gerais (DEN/UFMG), Belo Horizonte, MG (Brazil). Departamento de Engenharia Nuclear

    2017-07-01

    Inorganic elements, from natural and anthropogenic sources are present in foods in different concentrations. With the increase in anthropogenic activities, there was also a considerable increase in the emission of these elements in the environment, leading to the need of monitoring the elemental composition of foods available for consumption. Numerous techniques have been used to detect inorganic elements in biological and environmental matrices, always aiming at reaching lower detection limits in order to evaluate the trace element content in the sample. Neutron activation analysis (INAA), applying the k{sub 0}-method, produces accurate and precise results without the need of chemical preparation of the samples – that could cause their contamination. This study evaluated the presence of inorganic elements in whole foods samples, mainly elements on trace levels. For this purpose, seven samples of different types of whole foods were irradiated in the TRIGA MARK I IPR-R1 research reactor - located at CDTN/CNEN, in Belo Horizonte, MG. It was possible to detect twenty two elements above the limit of detection in, at least, one of the samples analyzed. This study reaffirms the INAA, k{sub 0} - method, as a safe and efficient technique for detecting trace elements in food samples. (author)

  6. Trace elements detection in whole food samples by Neutron Activation Analysis, k0-method

    International Nuclear Information System (INIS)

    Sathler, Márcia Maia; Menezes, Maria Ângela de Barros Correia; Salles, Paula Maria Borges de

    2017-01-01

    Inorganic elements, from natural and anthropogenic sources are present in foods in different concentrations. With the increase in anthropogenic activities, there was also a considerable increase in the emission of these elements in the environment, leading to the need of monitoring the elemental composition of foods available for consumption. Numerous techniques have been used to detect inorganic elements in biological and environmental matrices, always aiming at reaching lower detection limits in order to evaluate the trace element content in the sample. Neutron activation analysis (INAA), applying the k 0 -method, produces accurate and precise results without the need of chemical preparation of the samples – that could cause their contamination. This study evaluated the presence of inorganic elements in whole foods samples, mainly elements on trace levels. For this purpose, seven samples of different types of whole foods were irradiated in the TRIGA MARK I IPR-R1 research reactor - located at CDTN/CNEN, in Belo Horizonte, MG. It was possible to detect twenty two elements above the limit of detection in, at least, one of the samples analyzed. This study reaffirms the INAA, k 0 - method, as a safe and efficient technique for detecting trace elements in food samples. (author)

  7. Clean laboratories and clean rooms for analysis of radionuclides and trace elements

    International Nuclear Information System (INIS)

    2003-01-01

    requirements are summarized of clean laboratory environments, for construction materials as well as for materials used during routine analysis, maintenance, and pitfalls in the analysis of radionuclides and elements at trace- and ultra trace levels. Current methodologies and practices are described for planning the installation of a clean environment as well as protocols for maximizing the benefit-to-cost ratio and for achieving QA/QC. Special emphasis is given to the analysis of radionuclides, and measurement of trace, minor and major elements using nuclear and related analytical techniques such as NAA and XRF. Also included are papers contributed by experts from India, the Netherlands, the United States of America and the IAEA Laboratories, Seibersdorf

  8. Epidemiology and trace elements.

    Science.gov (United States)

    Elwood, P C

    1985-08-01

    Basically, epidemiology is the making of measurements of known reproducibility, in a bias-free manner, on representative samples of subjects drawn from defined communities. Epidemiology has become a relatively precise science and its value in medicine is widely appreciated. So too are its limitations: the difficulties in achieving a high response rate, in identifying and controlling confounding factors in the examination of an association, and the ultimate difficulties in distinguishing causation from association. While the value of community-based studies seems to be recognized by those interested in man and his environment, the need for the strict application of epidemiological procedures, and the limitations imposed on conclusions drawn from studies in which these procedures have been compromised, does not seem to be adequately understood. There are certain known links between trace elements in the environment and disease: for example the level of iodine in soil and water and the prevalence of goitre; the level of fluoride in water and the prevalence of dental caries. The investigation of other possible associations is difficult for a number of reasons, including interrelationships between trace elements, confounding of trace element levels (and disease) with social and dietary factors, and the probability that relationships are generally weak. Two conditions in which associations are likely are cardiovascular disease and cancer. Despite research along a number of lines, the relevance of trace elements to cardiovascular disease is not clear, and certainly the apparent association with hardness of domestic water supply seems unlikely to be causal. The same general conclusion seems reasonable for cancer, and although there are a very few well established associations which are likely to be causal, such as exposure to arsenic and skin cancer, the role of trace elements is obscure, and likely to be very small.

  9. Studies of sand drift by neutron activation analysis of trace elements in natural sand

    International Nuclear Information System (INIS)

    Ma, J.; Chai, Z.; Ma, S.; Mao, X.; Qian, Q.; Mao, Z.; Yan, P.

    1991-01-01

    On the basis of the inhomogeneous distribution of trace elements in nature and essential characteristics of the sand drift, the authors have proposed a so-called mix-model of trace elements as a law of the sand drift, and developed a few calculation methods to determine the drift directions, possible sources as well as their contributions to the sand. Using neutron activation analysis method for determining the concentrations of the trace elements in natural sand samples from different sources, they have investigated three areas, the Shantou Harbor, the Shanghai Harbor and a section of the Great Canal of China, to decipher the movement and sedimentation tendency of the sands there. Their results agree with those by conventional measurement methods in water conservancy works, and their method has provided some obvious advantages of time-saving, cost-saving, sampling without restriction of time and ease to be implemented

  10. Application of neutron activation analysis for determination of trace element Pt in the rat's tissue sample

    International Nuclear Information System (INIS)

    Wardani, S.; Mulyaningsih, R.

    1996-01-01

    The neutron activation analysis (NAA) have been developed as an analytical method with fast, high sensitivity, high accuracy and high precision for medical research purposes to determine the trace elements in the rat's tissue sample. Determination of the trace elements Pt and Se have done using bovine liver standard of NBS as a reference. This standard has used also as a tool to verify an equipment and method will be used further. The measurement results shows that using the available equipment and method, the lower limit of detection for Pt was 1 ppm. Distribution of the trace elements Pt and Se in the different rat's tissue previously treated with cisplatin can be determined. The results shows that Pt content in the several rat's tissue previously treated cisplatin plus sodium selenite is much bigger than that previously treated with cisplatin only. (author)

  11. Trace element analysis in liquids by proton induced x-ray emission

    International Nuclear Information System (INIS)

    Deconninck, G.

    Proton induced x-ray emission (PIXE) from liquid has been developed for quantitative and simultaneous analysis of trace elements. Liquid drops and trickles are bombarded at atmospheric pressure, x-rays are detected in a non dispersive Si(Li) solid state detector. Absolute determinations are made by comparison with standard solutions. Detection limits in a 5 minutes run are in the ppm range for a single drop (0.05 ml). The application of this technique to the determination of trace elements in biological liquids is investigated (Cr, Mn, Fe, Co, Ni, Cu, Zn, in plant extracts, haemocyanine, albumins...). (author)

  12. Archaeological significance of trace element analysis of South West African potsherds

    International Nuclear Information System (INIS)

    Boule, G.J.; Peisach, M.; Jacobson, L.

    1979-01-01

    The archaeological study of early population movements in South West Africa/Namibia has been aided by trace element analysis of potsherds. The results suggest that the central areas of the country were populated by mobile groups of pastoralists and hunter-gatherers, while the northern areas were settled by sedentary peoples [af

  13. Trace elements monitored with neutron activation analysis durig neurodegeneration in brains of mutant mice

    Czech Academy of Sciences Publication Activity Database

    Kranda, Karel; Kučera, Jan; Bäurle, J.

    2006-01-01

    Roč. 269, č. 3 (2006), s. 555-559 ISSN 0236-5731 Institutional research plan: CEZ:AV0Z10480505 Keywords : trace elements * neutron activation analysis * brain neurodegeneration * mutant mice Subject RIV: CB - Analytical Chemistry, Separation Impact factor: 0.509, year: 2006

  14. Trace elements in cigarette tobacco by a method of instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Noordin Ibrahim

    1986-01-01

    A total of ten cigarette brands were investigated for determining the trace elemental concentrations in tobacco so as to assess their role in the induction of related diseases through smoking. A method instrumental Neutron Activation analysis was employed due to high sensitivity, speed and ability to analyse sample for a wide spectrum of elements simultaneously. A total of 18 elements were detected of which the majority are toxic elements. A full result and conclusion will be reported in the forthcoming paper. (A.J.)

  15. Improved PIXE analysis of micro- and trace elements in dental composites

    International Nuclear Information System (INIS)

    Preoteasa, E. A.; Ciortea, C.; Fluerasu, D.; Enescu, S. E.; Preoteasa, E.

    2001-01-01

    Due to the interactions occurring at the solid-solid and solid-liquid interfaces of a tooth's filling, the mineral elements of the restorative composite may induce a complex response of the organism. To study such problems, sensitive surface trace element analysis is required. Particle-induced X-ray emission (PIXE) has a detection limit one order of magnitude lower than XRF and has been used for hard dental tissues, but not yet for dental composites. We evaluated the potential of PIXE in a study of ten types of composites used in restorative dentistry, some of them with two color shades each. The samples were prepared as described for XRF. The measurements were performed with 3 MeV protons from a van de Graaff tandem linear accelerator, using a hyper pure Ge detector and collecting the spectra for 1.5-4 hours. The spectra were processed with the program Leone. The proton route in the sample calculated with the Trim program (∼ 50-100 μm) exceeded the size of mineral particles (0.02-30 μm), thus granularity did not affect the analysis. The PIXE analysis detected Z ≥ 19 elements in all composites, and Z≥14 elements in only one low Z material. PIXE detected generally the same dominant elements, but many more trace elements than XRF. Thus both Charisma (Kulzer) and Pekafill (Bayer) contained Ba as the major element, but trace elements were Ni, Zn, In, in the first, and Fe, Cu, Zn, Sr, Ag in the second. In other glass- and ceramics-based materials we found: Ca, Zr, Ba, Yb and traces of Sr, In, and possibly Ti in Tetric Ceram and in Ariston (both from Vivadent); Ca, Zr, Ba, Hf, possibly Mn, and traces of Ni, Ho, Ti, Fe, Cr in Valux Plus (3M Dental); Sr, Ba (major), K, Fe, Mn (minor), and traces of Ni, Zn, In, in F2000 Compomer (3M Dental); Ba (major) and traces of Fe, Ni, Sr in Surefil (Dentsply). In quartz-based materials we detected: Si, Ca, Ti, Fe and traces of K, Cl, Cr, Ni, Cu, Zn in Evicrol (Spofa); low and trace levels of Ca, Ti, Cr, Mn, Fe, Cu in

  16. Determination of trace element impurities in aspirin tablets by neutron activation analysis

    International Nuclear Information System (INIS)

    Iskander, F.Y.; Klein, D.E.; Bauer, T.L.

    1986-01-01

    Twenty-five trace and minor elements in five different Egyptian aspirin brands (Aspo, Askin, Aspocid, Aspeol and Rivo) were determined by instrumental neutron activation analysis. It was concluded that the concentration of As, Ba, Br, Co, Cr, Fe (except in Aspocid), Mg, Mn, Rb, Se, Sr and Zn in the Egyptian brands is below or within the concentration range reported for these elements in 16 American aspirin and aspirin-like brands. (author)

  17. Determination of trace elements in wool fibre by instrumental neutron activation analysis and relation between trace element contents and quality of wool

    International Nuclear Information System (INIS)

    Eozyol, H.

    1990-01-01

    Wool samples were analyzed by neutron activation analysis and 17 elements, Al, Ag, Au, As, Br, Ca, Co, Cr, Cu, Fe, La, Mg, Mn, Na, Sb, Se and Zn were measured quantitatively. The presence of seven others, Ce, Eu, I, Mo, Te and W was noted. Since several elements, such as Cd, Hg and Pb could not be conveniently determined by NAA, Atomic Absorption Spectroscopy (AAS) was used instead. Cu and Zn were also analyzed by NAA and AAS to compare these two methods. Mechanical properties of samples were measured and the relations between the trace element contents and properties were investigated. (author) 16 refs.; 7 tabs

  18. Trace element analysis at the Livermore pool-type reactor using neutron activation techniques

    International Nuclear Information System (INIS)

    Ragaini, R.C.; Ralston, R.; Garvis, D.

    1975-01-01

    The capabilities of trace element analysis at the Livermore Pool-Type Reactor (LPTR) using instrumental neutron activation analysis (INAA) are discussed. A description is given of the technology and the methods employed, including sample preparation, irradiation, and analysis. Applications of the INAA technique in past and current projects are described. A computer program, GAMANAL, has been used for nuclide identification and quantification. (U.S.)

  19. Trace element analysis in ants collected in Japan, Finland and Sweden

    Energy Technology Data Exchange (ETDEWEB)

    Kitao, K. [National Inst. of Radiological Sciences, Chiba (Japan)

    1992-12-31

    Particle induced x-ray emission has been used to determine the concentration of trace elements in ants (Formicidae). Scanning PIXE analysis was also used to determine the distribution of these elements. Samples of ants were collected from gardens, buildings or from the roadway in Japan. Finland and Sweden. The only pre-treatments were dusting and washing. In each run of experiments we used only one individual ant and have obtained the analytical results of a reasonable accuracy. We have detected chemical minor elements, i.e., Mn, Fe, Cu, Zn, Rb, Br and Sr. The PIXE, and scanning PIXE method proved to be useful and sensitive enough to measure trace elements in such small insects as ants. (author).

  20. Trace element analysis in ants collected in Japan, Finland and Sweden

    International Nuclear Information System (INIS)

    Kitao, K.

    1992-01-01

    Particle induced x-ray emission has been used to determine the concentration of trace elements in ants (Formicidae). Scanning PIXE analysis was also used to determine the distribution of these elements. Samples of ants were collected from gardens, buildings or from the roadway in Japan. Finland and Sweden. The only pre-treatments were dusting and washing. In each run of experiments we used only one individual ant and have obtained the analytical results of a reasonable accuracy. We have detected chemical minor elements, i.e., Mn, Fe, Cu, Zn, Rb, Br and Sr. The PIXE, and scanning PIXE method proved to be useful and sensitive enough to measure trace elements in such small insects as ants. (author)

  1. Investigation of trace elements in Elbe water by means of instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Motamedi, K.

    1977-01-01

    Investigations of trace elements in Elbe water were carried out as a contribution to environmental research, hydrology, and geochemistry. The method applied - instrumental neutron activation analysis - is described, and problems connected with the course of analysis - sample taking, handling and preparation as well as optimization of in-pile irradiation and measurement by means of γ spectrometry - are discussed and presented one by one. The computer programme set up for automatic evaluation is described in more detail. This programme AKAN has a very general concept which makes it applicable for general use. The reliability of the evaluation procedure - monostandard method - and the reproducibility of the results are discussed. For the studies, samples were taken at different times, every time from 8 positions along a long section of the Elbe. The content of solids was analyzed; in a number of samples, this was done by separating suspended and dissolved materials. Up to 38 elements were analyzed, whose local and time-dependent concentration curves are given. The contents of some elements are compared with the few available data from literature. Correlation calculations indicate a similar behaviour of single element groups and yield information on the natural origin of the trace elements and on anthropogenic influence to be noticed in the trace element contents. (orig.) [de

  2. Methods for analysis of trace elements in coal, coal fly ash, soil, and plant samples. [59 refs

    Energy Technology Data Exchange (ETDEWEB)

    Slates, R.V.

    1976-11-01

    Results of a literature search are presented, and analytical methods are proposed for studies of trace elements in coal, coal ash residue, soil, and vegetation. Increased trace element levels in soils and plants collected near power plants have been reported by several investigators. Many sample dissolution and analysis techniques were used in the reported studies. A nine-laboratory comparison of trace element analyses for a variety of methods showed excessive variation relative to quoted uncertainty limits. Analysis results from a subsequent four-laboratory comparison of instrumental nuclear techniques for trace element analysis agreed with the National Bureau of Standards certified values for all nine elements determined. Instrumental neutron activation analysis, spark source mass spectrometry, and atomic absorption spectrometry are proposed as primary analysis methods for coal, coal ash, soil, and plants in a Savannah River Laboratory study of trace elements. Bomb procedures are proposed for dissolution of samples.

  3. Trace element analysis in the serum and hair of Antarctic leopard seal, Hydrurga leptonyx, and Weddell seal, Leptonychotes weddellii

    International Nuclear Information System (INIS)

    Gray, Rachael; Canfield, Paul; Rogers, Tracey

    2008-01-01

    Leopard seal, Hydrurga leptonyx, and Weddell seal, Leptonychotes weddellii, occupy an upper trophic level within the Antarctic ecosystem and are useful indicator species in the Southern Ocean of trace element concentrations. Reference values for the concentration of 19 trace elements were determined in the serum and hair of leopard and Weddell seals sampled in Eastern Antarctica. These reference values can be used as 'baseline' levels for monitoring trace element concentrations in these species. Greater trace element concentrations were determined in hair compared to serum, indicating different time scales of trace element accumulation in these samples. For the majority of trace elements, except for Se in the leopard seal samples and Cr in the Weddell seal samples, significant regression relationships for trace element concentrations in hair and serum were not elucidated. Significant differences were determined in the concentrations of seven out of 15 elements with hair type, moult and new, in the leopard seal; concentrations in moult hair were determined to be greater than in new hair for all elements except Zn. Hair analysis was determined to be useful for monitoring exposure to trace elements and when collected off the ice from moulting seals, hair can be employed as a non-invasive sample for trace element analysis in leopard and Weddell seals

  4. Trace element analysis in the serum and hair of Antarctic leopard seal, Hydrurga leptonyx, and Weddell seal, Leptonychotes weddellii

    Energy Technology Data Exchange (ETDEWEB)

    Gray, Rachael [Faculty of Veterinary Science, University of Sydney, NSW 2006 Australia (Australia); Australian Marine Mammal Research Centre PO Box 20 Mosman, NSW 2088 (Australia)], E-mail: rgray@vetsci.usyd.edu.au; Canfield, Paul [Faculty of Veterinary Science, University of Sydney, NSW 2006 (Australia); Rogers, Tracey [Australian Marine Mammal Research Centre PO Box 20 Mosman, NSW 2088 (Australia); Evolution and Ecology Research Centre and School of Biological Earth and Environmental Sciences, University of New South Wales, NSW 2052 (Australia)

    2008-07-25

    Leopard seal, Hydrurga leptonyx, and Weddell seal, Leptonychotes weddellii, occupy an upper trophic level within the Antarctic ecosystem and are useful indicator species in the Southern Ocean of trace element concentrations. Reference values for the concentration of 19 trace elements were determined in the serum and hair of leopard and Weddell seals sampled in Eastern Antarctica. These reference values can be used as 'baseline' levels for monitoring trace element concentrations in these species. Greater trace element concentrations were determined in hair compared to serum, indicating different time scales of trace element accumulation in these samples. For the majority of trace elements, except for Se in the leopard seal samples and Cr in the Weddell seal samples, significant regression relationships for trace element concentrations in hair and serum were not elucidated. Significant differences were determined in the concentrations of seven out of 15 elements with hair type, moult and new, in the leopard seal; concentrations in moult hair were determined to be greater than in new hair for all elements except Zn. Hair analysis was determined to be useful for monitoring exposure to trace elements and when collected off the ice from moulting seals, hair can be employed as a non-invasive sample for trace element analysis in leopard and Weddell seals.

  5. Trace element analysis in the serum and hair of Antarctic leopard seal, Hydrurga leptonyx, and Weddell seal, Leptonychotes weddellii.

    Science.gov (United States)

    Gray, Rachael; Canfield, Paul; Rogers, Tracey

    2008-07-25

    Leopard seal, Hydrurga leptonyx, and Weddell seal, Leptonychotes weddellii, occupy an upper trophic level within the Antarctic ecosystem and are useful indicator species in the Southern Ocean of trace element concentrations. Reference values for the concentration of 19 trace elements were determined in the serum and hair of leopard and Weddell seals sampled in Eastern Antarctica. These reference values can be used as 'baseline' levels for monitoring trace element concentrations in these species. Greater trace element concentrations were determined in hair compared to serum, indicating different time scales of trace element accumulation in these samples. For the majority of trace elements, except for Se in the leopard seal samples and Cr in the Weddell seal samples, significant regression relationships for trace element concentrations in hair and serum were not elucidated. Significant differences were determined in the concentrations of seven out of 15 elements with hair type, moult and new, in the leopard seal; concentrations in moult hair were determined to be greater than in new hair for all elements except Zn. Hair analysis was determined to be useful for monitoring exposure to trace elements and when collected off the ice from moulting seals, hair can be employed as a non-invasive sample for trace element analysis in leopard and Weddell seals.

  6. Use of a neutron activation analysis for studying the behavior of trace elements in river water

    Energy Technology Data Exchange (ETDEWEB)

    Tanizaki, Yoshiyuki [Tokyo Metropolitan Isotope Research Center (Japan)

    1996-12-31

    The determination of the physicochemical forms of trace elements, therefore, is of great importance not only to estimate the availability and toxicity toward aquatic organisms but to substantiate the geochemical behavior of trace elements in river waters. The trace element species in river water can be classified according to their size or molecular weight ranging. I tried to speciate 40 elements in river waters using both the filtration and ultrafiltration techniques combined with neutron activation analysis. Trace elements were first separated by size between two fractions, the suspended size (>0.45{mu}m) and the dissolved size (<0.45{mu}m) fractions using a Millipore filter. The constituents fractionated in the dissolved size fraction were further classified into three fractions by molecular weight (MW) ranging, colloidals (MW>10{sup 4}), complexes (MW10{sup 4}-500), and simple ions (MW<500), using ultrafilters. The colloidal and complex species were further separated organic and/or inorganic species using a gamma-ray irradiation technique. It was clarified that the dissolved species of the alkali and alkaline earth elements, Al, V, Mn, Sb and Au were mainly present as simple inorganic ions in river waters. The dissolved heavy rare earth elements, Sc, Cr, Co, Ni, Zn and Se predominantly existed as soluble organic complexes, even though significant amounts of Cr, Co, Ni, Zn and Se were also present as simple ions. The dissolved light rare earth elements, Fe, Ag, and Th were chiefly associated with organic colloids. The elements As, Mo and W which tend to form their oxoanions, on the other hand, may be held on inorganic colloids having small size. (J.P.N.)

  7. Solvent extraction of oil-sand components for determination of trace elements by neutron activation analysis

    International Nuclear Information System (INIS)

    Jacobs, F.S.; Filby, R.H.

    1983-01-01

    Instrumental neutron activation analysis was used to measure the concentrations of 30 elements in Athabasca oil sands and oil-sand components. The oil sands were separated into solid residue, bitumen, and fines by Soxhlet extraction with toluene-bitumen extract. The mineral content of the extracted bitumen was dependent on the treatment of the oil sand prior to extraction. The geochemically important and organically associated trace element contents of the bitumen (and asphaltenes) were determined by subtracting the mineral contributions from the total measured concentrations. The method allows analysis of the bitumen without the necessity of ultracentrifugation or membrane filtration, which might remove geochemically important components of the bitumen. The method permits classification of trace elements into organic and inorganic combinations

  8. [Trace elements of bone tumors].

    Science.gov (United States)

    Kalashnikov, V M; Zaĭchik, V E; Bizer, V A

    1983-01-01

    Due to activation analysis involving the use of neutrons from a nuclear reactor, the concentrations of 11 trace elements: scandium, iron, cobalt, mercury, rubidium, selenium, silver, antimony, chrome, zinc and terbium in intact bone and skeletal tumors were measured. 76 specimens of bioptates and resected material of operations for bone tumors and 10 specimens of normal bone tissue obtained in autopsies of cases of sudden death were examined. The concentrations of trace elements and their dispersion patterns in tumor tissue were found to be significantly higher than those in normal bone tissue. Also, the concentrations of some trace elements in tumor differed significantly from those in normal tissue; moreover, they were found to depend on the type and histogenesis of the neoplasm.

  9. PIXE analysis of trace and other mineral elements in phytopharmaceutical drugs

    International Nuclear Information System (INIS)

    Preoteasa, E. A.; Harangus, Livia; Iordan, Andreea; Gugiu, M.

    2002-01-01

    Despite of ongoing progress in the biochemistry of phytopharmaceutical drugs, their mineral micro- and trace elements have not been studied in detail. These elements may have therapeutic or toxic activity which should be assessed by sensitive investigations. The latter can be done by multielemental analysis with nuclear and atomic methods. We previously found 28 elements in some Romanian plant drugs by nuclear activation analysis. The availability of this method is, however, limited by the access to a nuclear reactor. Particle-induced X-ray emission (PIXE) is an alternative method with high performances in biomedicine and requiring no sample preparation for drugs' studies. We applied PIXE in the qualitative analysis of three plant drugs - Liv52, Mentat, and Geriforte - used as invigorators, protectors and prophylactics in oxidative stress diseases. Measurements with 3 MeV protons at the 8.5 MV NIPNE-HH (Horia Hulubei National Institute for Physics and Nuclear Engineering) tandem accelerator, using a hyper-pure Ge detector and no additional absorber foil, evidenced unusually complex elemental compositions of drugs. Up to 31 elements with Z > 15 were found: P, S, Cl, K, Ca, Sc, Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, Ga, Br, Rb, Sr, Y, Zr, Cs, Ba, La, Ce, Pr, Nd, Sm, Eu, Hg, and As and/or Pb, from major to trace levels. The three drugs' qualitative composition were found to be rather similar. Relative concentrations were well evaluated with X-ray yields calculated for another kind of light element thick target. Drug's toxic elements - As and/or Pb, Hg, and possibly Ga - were all at trace levels, but their accumulation might be harmful. Some essential elements like K, Ca, Cr, Fe, Cu, Zn, Br, Rb, Sr can be biologically useful. X-ray yields improvement and other ways for PIXE quantitative analysis of the phytotherapeutic drugs are outlined. (authors)

  10. Trace Elements in Human Myocardial Infarction Determined by Neutron Activation Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Wester, P.O.

    1965-05-15

    By means of neutron activation analysis, injured and adjacent uninjured human heart tissue from 12 autopsy cases with myocardial infarction are investigated with respect to the concentration of 23 trace elements. The bulk elements K, Na and P are also determined. A recently developed ion-exchange technique, combined with subsequent y-spectrometry, is used. The following trace elements are determined: Ag, As, Au, Ba, Br, Ca, Cd, Ce, Co, Cr, Cs, Cu, Fe, Hg, La, Mo, Rb, Sb, Sc, Se, Sm, Zn and W. In the injured tissue compared to the uninjured, calculation on a wet weight basis showed a decrease in Co, Cs, K, Mo, P, Rb and Zn, and an increase in Br, Ca, Ce, La, Na, Sb and Sm. The differences in Ca, La, Mo, P and Zn are dependent on the age of the myocardial infarction, and the regression lines for these elements are given. The concentration of the trace elements in uninjured tissue from infarcted hearts is compared to the concentration of these elements in normal heart tissue, determined in a previous study. In the uninjured tissue from infarcted hearts a decrease is found in Cu and Mo, and an increase in As and Ce.

  11. Trace Elements in Human Myocardial Infarction Determined by Neutron Activation Analysis

    International Nuclear Information System (INIS)

    Wester, P.O.

    1965-05-01

    By means of neutron activation analysis, injured and adjacent uninjured human heart tissue from 12 autopsy cases with myocardial infarction are investigated with respect to the concentration of 23 trace elements. The bulk elements K, Na and P are also determined. A recently developed ion-exchange technique, combined with subsequent y-spectrometry, is used. The following trace elements are determined: Ag, As, Au, Ba, Br, Ca, Cd, Ce, Co, Cr, Cs, Cu, Fe, Hg, La, Mo, Rb, Sb, Sc, Se, Sm, Zn and W. In the injured tissue compared to the uninjured, calculation on a wet weight basis showed a decrease in Co, Cs, K, Mo, P, Rb and Zn, and an increase in Br, Ca, Ce, La, Na, Sb and Sm. The differences in Ca, La, Mo, P and Zn are dependent on the age of the myocardial infarction, and the regression lines for these elements are given. The concentration of the trace elements in uninjured tissue from infarcted hearts is compared to the concentration of these elements in normal heart tissue, determined in a previous study. In the uninjured tissue from infarcted hearts a decrease is found in Cu and Mo, and an increase in As and Ce

  12. Determination of trace elements in leaves of tropical trees in Malaysia by neutron activation analysis

    International Nuclear Information System (INIS)

    Aidid, S.B.

    1988-01-01

    Instrumental neutron activation analysis was used to measure 17 elements in 2 families of leaves of tropical plants. The concentrations of most of the trace elements measured, especially toxic elements like As, Br, Cr, Hg, Sb and Zn, were found to correlate well with the polluted nature of the locations where the trees were grown and also with the age of the plants. It was observed that the trees used in this study could be used as bioindicators for the pollution state of the surrounding environment. (author) 9 refs.; 6 tabs

  13. Major and Trace Element Analysis of Natural and Experimental Igneous Systems using LA-ICP-MS

    Science.gov (United States)

    Jenner, Frances E.; Arevalo, Ricardo D., Jr.

    2016-01-01

    Major- and trace-element compositions of minerals provide valuable information on a variety of global Earth-system processes, including melting of distinct mantle reservoirs, the growth and evolution of the Earths crust and the formation of economically viable ore deposits. In the mid-1980s and early 1990s, attempts were made to couple laser ablation (LA) systems to inductively coupled plasma mass spectrometry (ICPMS) instruments (e.g. Fryer et al. 1995; Jackson et al. 1992). The goal was to develop a rapid, highly sensitive in situ analytical technique to measure abundances and spatial distributions of trace elements in minerals and other geological samples. Elemental analysis using LAICPMS was envisaged as a quicker and less destructive means of chemical analysis (requiring only g quantities) than labour-intensive sample digestion and solution analysis (requiring mg-levels of material); and it would be a more cost-effective method than secondary ion mass spectrometry (SIMS) for the routine analysis of trace elements from solid samples. Furthermore, it would have lower limits-of-detection than electron probe microanalysis (EPMA) (e.g. Jackson et al. 1992; Eggins 2003).

  14. Trace elements in Turkish tobacco determined by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Gulovali, M.C.

    1977-01-01

    This study was undertaken to determine the concentration of trace elements in nine different brands of Turkish cigarette tobacco, pipe tobacco and tobacco ash. Instrumental neutron activation analysis was employed, and a gamma-ray spectrometer consisting of 40 cm 3 Ge(Li) detector coupled to 1024 and 4096-channel analyzers were used. Samples were irradiated at a thermal neutron flux of about 10 13 cm -2 sec -1 . Concentrations of Na, K, Sc, Cr, Fe, Co, Zn, As, Se, Br, Rb, Sb, Cs, Ba, La, Ce, Eu, Hf, Hg and Th were determined in tobacco and ash; percent transference of these elements into ash were calculated. It was found out that trace elements in cigarette tobacco are left in the ash but only a small percentage is transferred into the smoke

  15. Trace elemental analysis of carcinoma kidney and stomach by PIXE method

    International Nuclear Information System (INIS)

    Reddy, S. Bhuloka; John Charles, M.; Naga Raju, G.J.; Vijayan, V.; Seetharami Reddy, B.; Ravi Kumar, M.; Sundareswar, B.

    2003-01-01

    Trace elemental analysis was carried out in the biological samples of carcinoma kidney and stomach using particle induced X-ray emission technique. A 2 MeV proton beam was employed to excite the samples. From the present results, the levels of elements K, Ca, Fe, Ni and Se are lower and those of the elements Ti, Co, Zn, As and Cd are higher in the cancer tissue of kidney than those observed in the normal tissue. In the case of stomach, the concentrations of elements Cl, K, Ca, Ti, Mn, Fe, Co, Cu and Zn are lower while concentrations of elements Cr, Ni, As and Br are higher in the cancer tissue of stomach than those observed in the normal tissue. The observed deficiency or excess of certain elements is correlated to carcinogenesis of that organ. The present results of carcinoma stomach support the previous observations that nickel and chromium are carcinogenic agents. The low levels of selenium observed in the carcinoma tissue of kidney and the low levels of manganese observed in the carcinoma tissue of stomach support the view that selenium and manganese inhibit the growth of cancer in kidney and stomach respectively. The observed high levels of zinc in the cancer tissue of kidney suggest that zinc is involved in the tumor growth and development of neoplastic transformation in kidney while the observed low levels of zinc in the carcinoma tissue of stomach suggest that zinc inhibits the growth of cancer in this organ. For correctly assessing the role played by the trace elements in initiating, promoting or inhibiting cancer in various organs, there is a need for acquisition of more data by trace elemental analysis from several investigations of this type undertaken in different regions

  16. Osteoporosis and trace elements

    DEFF Research Database (Denmark)

    Aaseth, J.; Boivin, G.; Andersen, Ole

    2012-01-01

    More than 200 million people are affected by osteoporosis worldwide, as estimated by 2 million annual hip fractures and other debilitating bone fractures (vertebrae compression and Colles' fractures). Osteoporosis is a multi-factorial disease with potential contributions from genetic, endocrine...... in new bone and results in a net gain in bone mass, but may be associated with a tissue of poor quality. Aluminum induces impairment of bone formation. Gallium and cadmium suppresses bone turnover. However, exact involvements of the trace elements in osteoporosis have not yet been fully clarified...

  17. Determination of short-lived trace elements in environmental samples by neutron activation analysis

    International Nuclear Information System (INIS)

    Wardani, S.; Sihombing, E.; Hamzah, A.; Rochidi; Hery, P.S.; Hartaman, S.; Iman, J.

    1998-01-01

    Concentration of a short-lived trace elements in environmental samples were determined by neutron activation analysis, a counting loss often occur due to the high counting rate. A Pile-Up Rejecter (PUR) electric circuit was installed in counting a short-lived trace elements by a γ-ray spectrometer in order to correct a counting loss. The samples were irradiated for 30∼60 seconds at neutron flux of 3.5 x 10 12 n.cm -2 .s -1 , then the samples cooled for 120 second and counted for 180 second using this system. The nuclides concentration in the varieties environmental samples have a difference analysis result, was more accurate and precise, which the measured result would be 30 % more higher by PUR system than the result would be counted using a conventional γ-ray spectrometry method

  18. Proton induced X-Ray fluorescence study as a tool trace element analysis

    International Nuclear Information System (INIS)

    El-Kady, Ahmed A.

    1978-01-01

    Usefulness and limitations of trace elemental analysis by high energy charged particles and photon induced X-ray have been discussed. Comparison with the well established neutron activation analysis technique is also given. Back-ground radiation due to bremsstrahlung from secondary electrons and due to charged particle bremsstrahlung have been reviewed for different projectiles. The sensitivity of elemental analysis by proton induced X-ray fluorescence have been examined by measuring the characteristic X-ray emission cross section for K and L transitions of many elements and for different proton energies and compared with theroretical values. The discussion given in this report show that with suitable proton generator and a high resolution X-ray detector, proton X-ray fluorescence technique is capable of analyzing many elements simultaneously at the part per million level and offers a rapid and reliable method for trace element analysis. Data on water, blood and tissue samples given in this report are few examples of many possible applications

  19. Distribution of trace elements in whole blood of Syrian lymphomas patients using instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Bakir, M. A.; Serhil, A.; Mohammad, A.; Habil, K.

    2013-12-01

    In recent years, there had been much interest in the concentrations of trace metals occurring in human and animal tissues and in the manner in which these concentrations may alter in malignant and other diseases. Neutron activation analysis is consider one of several methods that have been described for the determination of trace elements in biological materials. This method possesses the sensitivity and specificity necessary for the estimation at the concentrations existing naturally in most tissues, particularly when only small samples are available for analysis. The purpose of this study was to compare blood concentrations of trace elements Co, Cr, Fe, Rb, Sc, Se, Th, and Zn of lymphomas Syrian patients with those of healthy volunteers. Also, determine the relationships between trace elements concentration and the histological type of lymphomas. The blood samples were collected from 39 healthy volunteers and 49 patients with histologically confirmed lymphomas (29 Hodgkin's HL and 20 non-Hodgkin's lymphomas NHL), and analyzed to obtain the concentration of the trace elements in blood. Then, comparison between the healthy volunteers and lymphomas patients (both HL and NHL) was made to elucidate differences of the concentration distributions of the elements in blood. However, statistical analysis using Student's t test revealed significantly high concentrations of Co, Cr, Sc, and Th in lymphoma patients. Whereas Fe and Rb were found significantly decreased in lymphomas patient comparing to control group. Increasing or decreasing concentrations of Se and Zn in lymphoma patients was found not significant. Comparison between the healthy volunteers and non-Hodgkin's lymphomas patients reveled that Co, Cr, Sc, and Th were significantly elevated whereas, Rb only one trace element was decreased and all change in concentrations (elevating or decreasing) of Se and Zn were not significant. Comparison between the healthy volunteers and Hodgkin

  20. Radiochemical neutron activation analysis for trace elements evaluation of human milk

    International Nuclear Information System (INIS)

    Gill, K.P.; Zaidi, J.H.; Ahmad, S.

    2003-01-01

    The principal objective pursued in this study is to establish the base-line data on the status of elemental composition in human milk from Pakistani subjects of Rawalpindi/Islamabad area. Radiochemical neutron activation analysis (RNAA) methodology was developed and successfully employed to determine the concentration of 18 minor and trace elements (essential, toxic and nonessential) in human milk. This methodology has significantly improved the detection limits of most of these elements due to suppression of Compton background. The data provide the base-line values of these elements in human milk of low- and medium-income group subjects of the region. The results obtained show good compatibility with the data reported by the WHO on elemental composition of human milk from different geological regions. (orig.)

  1. Trace elemental analysis of adenoma and carcinoma thyroid by PIXE method

    Science.gov (United States)

    Reddy, S. Bhuloka; John Charles, M.; Ravi Kumar, M.; Reddy, B. Seetharami; Anjaneyulu, Ch.; Naga Raju, G. J.; Sundareswar, B.; Vijayan, V.

    2002-11-01

    Trace elemental analysis was carried out in the biological samples of normal, adenoma and carcinoma thyroids using particle induced X-ray emission technique (PIXE). A 2 MeV proton beam was employed to excite the samples. The elements Cl, K, Ca, Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, As, Sr, I, Hg and Pb were identified and their concentrations were estimated. The concentrations of the elements Ca, Cu, Zn, As, I and Hg are found to be much lower in carcinoma thyroid than those in the normal thyroid while the concentration of the elements K, Ti, V, Cr, Mn, Fe, Co and Sr in carcinoma thyroid are higher than the concentrations in normal thyroid. The lower and higher values of some of the elements in carcinoma thyroid may be attributed to some pathological factors.

  2. Activation analysis of hair as an indicator of contamination of man by environmental trace element pollutants

    International Nuclear Information System (INIS)

    Ryabukhin, Yu.S.

    1976-10-01

    The burning of fossil fuel, discharges from metallurgical and chemical plants, the wide use of chemicals, and other human activities, result in releasing into the biosphere large quantities of elements which are found in relatively low concentrations in the human organism. The pollution of the biosphere by such trace elements, and in particular heavy metals, has reached such proportions that on the scale of significance of the factors causing the 'stressed' state of the environment of heavy metals occupy the second place and, according to forecasts, may in the future move on to the first. In the problem of pollution of the biosphere, man himself undoubtedly occupies the central position as a target. The pollution of air, soil and water, the contamination of micro-organisms, plants and animals are certainly growing into a serious threat and leading to heavy losses. However, it would be a real disaster if man himself became contaminated to levels giving rise to large scale harmful somatic or genetic effects. It is therefore an urgent problem today to determine the initial levels of trace elements in man and the extent of his contamination in areas where these elements are expected to show anomalous concentrations. Attention should be paid in the first place to those trace elements which probably play no physiological role, are particularly abundant in the environment, and have high toxicity (arsenic, mercury, lead, cadmium, etc.). Moreover, it should be born in mind that in anomalously high concentrations even the physiologically necessary trace elements (copper, zinc, manganese, fluorine, etc.) cause harmful effects. This paper justifies the use of hair samples as a biological indicator of environmental pollutants from physiological and morphological aspect and recommends on sample preparation and analysis methods

  3. Accurate determination of trace elements in sediment CRMs by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Becker, D.A.

    1999-01-01

    The accurate determination of major, minor and trace elements in two sediment reference materials is described. One material is from the National Institute of Standards and Technology (SRM 1646a), and the other is from the National Research Council of Canada (HISS-1). The analytical technique used was high accuracy instrumental neutron activation analysis. The procedures used are described, the problems found are discussed, and the results obtained are compared to the certified values for both CRMs. (author)

  4. X-ray fluorescence analysis for trace element determination in foodstuff chemistry

    International Nuclear Information System (INIS)

    Wildanger, W.

    The physical fundamentals of X-ray fluorescence analysis are given and the routine spectrometers described. The basic principles are given of analytical methods used in qualitative and quantitative fluorescence analyses. Examples are given of the use of the method in a number of fields and the possibility and usefulness is discussed for the determination of trace elements in foodstuffs. The preparation of samples, preliminary concentration of components and calibration methods are discussed. (M.K.)

  5. Analysis of trace elements by means of accelerator secondary ion mass spectrometry

    International Nuclear Information System (INIS)

    Ender, R.M.

    1997-01-01

    The analysis of material composition and trace element concentration is of increasing interest primarily in semiconductor technology but also in metallurgy, geology, biology and medicine. At present, Secondary Ion Mass Spectrometry (SIMS) is in many respects the best technique to provide 3-dimensional information on the distribution of trace elements with concentrations below 1 ppm. However, due to the presence of molecular ions the detectability of many trace elements it restricted because of molecular mass interferences. In addition, detectors used in SIMS have a background counting rate of 0.1-1 Hz, which further limits trace element analysis. In Accelerator Mass Spectrometry (AMS) long-lived radionuclides are detected free of molecular interferences and detector background at isotopic ratios as low as 10 -15 . Moreover, isobaric interferences can be reduced as well. In order to benefit from these advantages a combination of SIMS and AMS (Accelerator SIMS) has been proposed almost 20 years ago, but no facility has ever been fully developed. It has been the aim of this work to add a new sputtering chamber for AMS measurements of ultrapure semiconductor material to the existing PSI/ETH AMS facility. To fulfill the requirements of material analysis, an UHV chamber with special precautions against contamination has been built and adapted to the existing AMS setup. For sputtering, a commercial Cs gun with an ExB filter and a 1 o beam bend for neutral particle suppression is used to obtain a pure Cs ion beam. The gun is equipped with different apertures for varying the diameter of the beam spot. With the integrated scanning unit the 10 keV Cs beam can be rastered over approximately 1 mm 2 . This allows different applications such as bulk analysis, depth profiling and imaging. The secondary ion extraction is matched to the ion optical and geometrical requirements of the existing accelerator mass spectrometer. (author) figs., tabs., 67 refs

  6. Determination of trace elements in a cigarette paper by neutron activation analysis

    International Nuclear Information System (INIS)

    Abedinzadeh, Z.; Khalkhali, Zh.; Razeghi, M.; Parsa, B.

    The concentration of 19 trace elements in a cigarette paper (Zig-Zag Paper Company, France) which is used in making different brands of Iranian cigarettes, has been measured by neutron activation analysis, employing a high-resolution Ge(Li) detector. They include Na, K, Ca, Sc, Cr, Mn, Fe, Co, Zn, Br, Sr, Sb, Ba, Ce, Eu, Gd, Au, Hg, and Th. (author)

  7. Analysis of trace elements in scalp hair for long-lived people, hypertensives and healthy students

    International Nuclear Information System (INIS)

    Wu Xiaofeng; Zhang Yurong; Zhang Longxing; Zhang Agen

    1989-01-01

    The XRF method was used to analyse nine kinds of trace elements in hair samples for three groups of people. While the information on long-lived people is used to explore the secret of long life, the work on hypertensives helps understand the effect of some trace elements on the disease. The normal values of trace elements for university students have been also set up

  8. PIXE analysis of trace elements in relation to chlorophyll concentration in Plantago ovata Forsk

    International Nuclear Information System (INIS)

    Saha, Priyanka; Sen Raychaudhuri, Sarmistha; Chakraborty, Anindita; Sudarshan, Mathummal

    2010-01-01

    Plantago ovata Forsk - an economically important medicinal plant - was analyzed for trace elements and chlorophyll in a study of the effects of gamma radiation on physiological responses of the seedlings. Proton-induced X-ray emission (PIXE) technique was used to quantify trace elements in unirradiated and gamma-irradiated plants at the seedling stage. The experiments revealed radiation-induced changes in the trace element and chlorophyll concentrations.

  9. Trace element analysis by EPMA in geosciences: detection limit, precision and accuracy

    Science.gov (United States)

    Batanova, V. G.; Sobolev, A. V.; Magnin, V.

    2018-01-01

    Use of the electron probe microanalyser (EPMA) for trace element analysis has increased over the last decade, mainly because of improved stability of spectrometers and the electron column when operated at high probe current; development of new large-area crystal monochromators and ultra-high count rate spectrometers; full integration of energy-dispersive / wavelength-dispersive X-ray spectrometry (EDS/WDS) signals; and the development of powerful software packages. For phases that are stable under a dense electron beam, the detection limit and precision can be decreased to the ppm level by using high acceleration voltage and beam current combined with long counting time. Data on 10 elements (Na, Al, P, Ca, Ti, Cr, Mn, Co, Ni, Zn) in olivine obtained on a JEOL JXA-8230 microprobe with tungsten filament show that the detection limit decreases proportionally to the square root of counting time and probe current. For all elements equal or heavier than phosphorus (Z = 15), the detection limit decreases with increasing accelerating voltage. The analytical precision for minor and trace elements analysed in olivine at 25 kV accelerating voltage and 900 nA beam current is 4 - 18 ppm (2 standard deviations of repeated measurements of the olivine reference sample) and is similar to the detection limit of corresponding elements. To analyse trace elements accurately requires careful estimation of background, and consideration of sample damage under the beam and secondary fluorescence from phase boundaries. The development and use of matrix reference samples with well-characterised trace elements of interest is important for monitoring and improving of the accuracy. An evaluation of the accuracy of trace element analyses in olivine has been made by comparing EPMA data for new reference samples with data obtained by different in-situ and bulk analytical methods in six different laboratories worldwide. For all elements, the measured concentrations in the olivine reference sample

  10. Trace element analysis of human blood serum by neutron activation analysis

    International Nuclear Information System (INIS)

    Nakahara, H.; Nagame, Y.; Yoshizawa, Y.; Oda, H.; Gotoh, S.; Murakami, Y.

    1979-01-01

    An attempt was made to determine if there is any correlation between trace element concentrations in human blood serum and some specific diseases. The serum samples of the patients suffering from cancer, Down syndrome, and Banti syndrome were analyzed by the neutron activation method and compared with the trace element concentrations observed among clinically healthy men. The cancer patients had concentrations in Rb, Mn, Fe, Co, Cu, Zn, Al and Se below normal. The Down syndrome patients were found to have similar deficiencies in Cr, Mn, Fe, Co, Zn, Cu and Sb. (author)

  11. Determination of trace elements in total particulate matter of cigarette smoke by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Mishra, U.C.; Shaikh, G.N.

    1985-01-01

    Cigarette smoke contains many trace elements hazardous for human body. Tobacco samples were analyzed for their trace element contents and the results were reported earlier. This paper presents results on the trace element content analyzed in cigarette smoke using an automatic smoking machine developed in laboratory to simulate actual smoking pattern. The trace element levels in the total particulate matter samples of the cigarette smoke collected on filter papers were measured and compared with those of cigarette smoke condensate reported in the literature. Both methods of collection give comparable results. (author)

  12. The determination of trace elements in new food grain SRM's using neutron activation analysis

    International Nuclear Information System (INIS)

    Gills, T.E.; Gallorini, M.; Rook, H.L.

    1978-01-01

    Potentially toxic metals in the food chain that can lead to deleterious effects on human health have been well documented. Because of the toxicity of some metals, levels of 1 ppm or less must be routinely monitored in foods to ensure human safety. To ensure the accuracy of measurement, NBS in a cooperative interagency agreement with the Food and Drug Administration is involved in developing and certifying selected elements in food grain as a part of the Standard Reference Material program. Both instrumental and radiochemical neutron activation analysis were used to analyze two food grain standard reference materials (Rice and Wheat Flours) for trace element certification. (author)

  13. Evaluation of trace elements in different species of lichens by neutron activation analysis

    International Nuclear Information System (INIS)

    Coccaro, D.M.B.; Saiki, M.; Vasconcellos, M.B.A.

    2000-01-01

    Instrumental neutron activation analysis has been applied for the determination of trace elements in five epiphytic lichens: Canoparmelia texana, Canoparmelia caroliniana, Parmotrema tinctorum, Parmotrema sancti-angeli and Usnea sp. that were collected at the same sampling area of the Botanic Institute, Sao Paulo, Brazil. The elemental concentration results showed that these five lichens can be chosen in the species intercalibration for biomonitoring studies. Also, some aspects related to the occurrence, tolerance to pollution, treatment and ease of sampling of the species are presented. (author)

  14. Certified sediment reference materials for trace element analysis from the National Metrology Institute of Japan (NMIJ).

    Science.gov (United States)

    Inagaki, Kazumi; Takatsu, Akiko; Kuroiwa, Takayoshi; Nakama, Atsuko; Eyama, Sakae; Chiba, Koichi; Okamoto, Kensaku

    2004-03-01

    Two types of sediment reference material (NMIJ 7302-a and 7303-a) for trace elements analysis have been prepared and certified by the National Metrology Institute of Japan in the National Institute of Advanced Industrial Science and Technology (NMIJ/AIST). The original materials were collected from a bay near industrial activity in Kyushu (NMIJ CRM 7302-a; marine sediment) and from Lake Biwa (NMIJ CRM 7303-a; lake sediment). The sediment materials were air-dried, sieved, homogenized, packaged in 1000 glass bottles (60 g each), and radiation sterilized. Certification of these CRM for trace elements was conducted by NMIJ, where each element was determined by at least two independent analytical techniques. Isotope-dilution inductively coupled plasma mass spectrometry (ICP-MS) was applied for certification of all the elements except mono-nuclide elements such as As and Co. Other techniques such as ICP-MS with quadrupole mass spectrometry and sector-field mass spectrometry, inductively coupled plasma atomic emission spectrometry (ICP-AES), and atomic absorption spectrometry (AAS), were also used. Certified values have been provided for 14 elements (Sb, As, Cd, Cr, Co, Cu, Pb, Hg, Mo, Ni, Se, Ag, Sn, and Zn) in both CRM.

  15. Trace elemental analysis of Indian natural moonstone gems by PIXE and XRD techniques

    International Nuclear Information System (INIS)

    Venkateswara Rao, R.; Venkateswarulu, P.; Kasipathi, C.; SivaJyothi, S.

    2013-01-01

    A selected number of Indian Eastern Ghats natural moonstone gems were studied with a powerful nuclear analytical and non-destructive Proton Induced X-ray Emission (PIXE) technique. Thirteen elements, including V, Co, Ni, Zn, Ga, Ba and Pb, were identified in these moonstones and may be useful in interpreting the various geochemical conditions and the probable cause of their inceptions in the moonstone gemstone matrix. Furthermore, preliminary XRD studies of different moonstone patterns were performed. The PIXE technique is a powerful method for quickly determining the elemental concentration of a substance. A 3 MeV proton beam was employed to excite the samples. The chemical constituents of moonstones from parts of the Eastern Ghats geological formations of Andhra Pradesh, India were determined, and gemological studies were performed on those gems. The crystal structure and the lattice parameters of the moonstones were estimated using X-Ray Diffraction studies, trace and minor elements were determined using the PIXE technique, and major compositional elements were confirmed by XRD. In the present work, the usefulness and versatility of the PIXE technique for research in geo-scientific methodology is established. - Highlights: • For the first time, PIXE technique was employed to analyze the East Indian natural moonstone gems. • The trace and minor elements are estimated using PIXE technique whereas major compositional elements are confirmed by XRD. • Adularia variety of moonstone is found to be abundant in the present study. • The PIXE analysis concludes that Eastern Ghats of India are rich not only in gemstones but also in trace elements

  16. Research review trends of food analysis in Latvia: major and trace element content.

    Science.gov (United States)

    Vincevica-Gaile, Zane; Klavins, Maris; Rudovica, Vita; Viksna, Arturs

    2013-10-01

    The current paper involves overview of several studies concerning quantitative major and trace element analysis of different food samples, such as products of plant origin, e.g., locally grown vegetables (carrots, onions, potatoes) and products of animal origin derived with or without processing (cottage cheese, eggs, honey). Food samples were collected over the territory of Latvia in the time period 2009-2012. Sample pre-treatment was chosen according to the product specifics but mostly wet mineralization with concentrated nitric acid was applied. Analysis of major elements (e.g., Ca, Fe, K, Mg, Na) and trace elements (e.g., As, Cd, Co, Cr, Cu, Ni, Pb, Se, Zn) was performed by appropriate quantitative analytical technique: atomic absorption spectrometry, inductively coupled plasma mass spectrometry or total reflection X-ray fluorescence spectrometry. Not only the influence of environmental factors (e.g., geographical or seasonal impact) was detected in element dissemination in food, also botanical origin (if applicable) and applied agricultural praxis, product processing and storage specifics were found to be important. Possible food contamination by potentially toxic elements can be associated mostly with the consequences of anthropogenic activities. The studies revealed the significance of food research in the context of environmental science.

  17. Determination of minor and trace elements concentration in kidney stones using elemental analysis techniques

    Science.gov (United States)

    Srivastava, Anjali

    The determination of accurate material composition of a kidney stone is crucial for understanding the formation of the kidney stone as well as for preventive therapeutic strategies. Radiations probing instrumental activation analysis techniques are excellent tools for identification of involved materials present in the kidney stone. The X-ray fluorescence (XRF) and neutron activation analysis (NAA) experiments were performed and different kidney stones were analyzed. The interactions of X-ray photons and neutrons with matter are complementary in nature, resulting in distinctly different materials detection. This is the first approach to utilize combined X-ray fluorescence and neutron activation analysis for a comprehensive analysis of the kideny stones. Presently, experimental studies in conjunction with analytical techniques were used to determine the exact composition of the kidney stone. The use of open source program Python Multi-Channel Analyzer was utilized to unfold the XRF spectrum. A new type of experimental set-up was developed and utilized for XRF and NAA analysis of the kidney stone. To verify the experimental results with analytical calculation, several sets of kidney stones were analyzed using XRF and NAA technique. The elements which were identified from XRF technique are Br, Cu, Ga, Ge, Mo, Nb, Ni, Rb, Se, Sr, Y, Zr. And, by using Neutron Activation Analysis (NAA) are Au, Br, Ca, Er, Hg, I, K, Na, Pm, Sb, Sc, Sm, Tb, Yb, Zn. This thesis presents a new approach for exact detection of accurate material composition of kidney stone materials using XRF and NAA instrumental activation analysis techniques.

  18. Trace element analysis on Si wafer surfaces by TXRF at the ID32 ESRF undulator beamline.

    Science.gov (United States)

    Ortega, L; Comin, F; Formoso, V; Stierle, A

    1998-05-01

    Synchrotron radiation total-reflection X-ray fluorescence (SR-TXRF) has been applied to the impurity analysis of Si wafers using a third-generation synchrotron radiation undulator source. A lower limit of detectability (LLD) for Ni atoms of 17 fg (1.7 x 10(8) atoms cm(-2)) has been achieved with an optical set-up based on an Si(111) double-crystal monochromator and a horizontal sample geometry. These first results are very promising for synchrotron radiation trace element analysis since we estimate that it is possible to lower the LLD by a factor of about 25 by employing appropriate optics and detectors. The use of a crystal monochromator opens new possibilities to perform absorption and scattering experiments (NEXAFS and X-ray standing-wave methods) for chemical and structural analysis of ultratrace elements.

  19. Investigation of different types of filters for atmospheric trace elements analysis by three analytical techniques

    International Nuclear Information System (INIS)

    Ali, A.E.; Bacso, J.

    1996-01-01

    Different atmospheric aerosol samples were collected on three types of filters. Disks of both loaded and clean areas of each kind of filter were investigated by XRF, PIXE and Scanning Electron Microscope (SEM) methods. The blank concentration values of the elements Al, Si, P, S, Cl, K, Ca, Sc, Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, As, Br and Pb in the three types of filters are discussed. It is found that for trace elemental analysis, the Nuclepore membrane filters are the most suitable for sampling. These have much lower blank element concentration values than the glass fibres and ash free filters. It was found also that the PIXE method is a more reliable analytical technique for atmospheric aerosol particles than the other methods. (author). 20 refs., 3 figs., 3 tabs

  20. Trace element contents in atmospheric suspended particles: inferences from instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Querol, X.; Alastuey, A.; Lopez-Soler, A.; Boix, A.; Sanfeliu, T.; Martynov, V.V.; Piven, P.I.; Kabina, L.P.; Souschov, P.A.

    1997-01-01

    This study focuses on the determination of trace element concentrations in total suspended particles by instrumental neutron activation analysis (INAA) in two different areas in Northeastern Spain (a rural area influenced by the emissions of a large coal-fired power station, and the urban and industrial areas of Castellon). Total suspended particles were sampled by means of standard MCV high- and medium-volume captors, using cellulose membrane filters of 0.8 and 0.45 μm pore size. Preliminary research was performed on the homogeneous distribution of elements in the sample filters and on the study of blank filters for the calculations of the background average element contents. The results obtained allowed to distinguish different major anthropogenic sources of trace elements in the atmosphere at the sampling sites: (a) Zr, Hf, Sc, U and Th are related to atmospheric pollution derived from the ceramic industry of the Castellon area; (b) As, Cr, Cs, Rb, Sb, Se, Zn are related to traffic and other industrial emission in the Castellon area, and As, Cr, Sb and Zn to power generation emissions in the rural area. (orig.). With 3 figs., 5 tabs

  1. Trace Elements in the Conductive Tissue of Beef Heart Determined by Neutron Activation Analysis

    International Nuclear Information System (INIS)

    Wester, P.O.

    1965-08-01

    By means of neutron activation analysis, samples of four beef hearts taken from the bundle of His and adjacent ventricular muscle, the AV node and adjacent atrial muscle are investigated with respect to the concentration of 23 trace elements. The bulk elements K, Na and P are also determined. A recently developed ion-exchange technique, combined with subsequent γ-spectrometry, is used. The following trace elements are determined: Ag, As, Au, Ba, Br, .Ca, Cd, Ce, Co, Cr, Cs, Cu, Fe, Hg, La, Mo, Rb, Sb, Sc, Se, Sm, W and Zn. In the conductive tissue compared to adjacent muscle tissue, calculations on a wet weight basis show a lower concentration of Cs, Cu, Fe, K, P, Rb and Zn in the former, and a higher concentration of Ag, Au, Br, Ca and Na. The mean differences (μg/g wet tissue), as well as their degree of significance, between the bundle of His and adjacent tissue from the ventricular septum, between the AV node and adjacent atrial muscle, between the ventricular septum and the right atrium, and between the bundle of His and the AV node are given for the elements Cu, Fe, K, Na, P and Zn

  2. Trace element determination study in human hair by neutron activation analysis

    International Nuclear Information System (INIS)

    Frazao, Selma Violato

    2008-01-01

    Human hair analysis studies have been subject of continuous interest due to the fact that they can be used as an important tool to evaluate trace element levels in the human body. These determinations have been carried out to use hair for environmental and occupational monitoring, to identify intoxication or poisoning by toxic metals, to assess nutritional status, to diagnose and to prevent diseases and in forensic sciences. Although hair analysis presents several advantages over other human tissue or fluid analyses, such as organ tissue, blood, urine and saliva, there are some controversies regarding the use of hair analysis data. These controversies arise from the fact that it is difficult to establish reliable reference values for trace elements in hair. The purpose of this study was to evaluate the factors that affect element concentrations in hair samples from a population considered healthy and residing in the Sao Paulo metropolitan area. The collected human head hair was cut in small pieces, washed, dried and analyzed by neutron activation analysis (NAA). Aliquots of hair samples and synthetic elemental standards were irradiated at the IEA-R1 nuclear research reactor for 16 h under a thermal neutron flux of about 5x10 12 n cm -2 s -1 for As, Br, Ca, Co, Cr, Cs, Cu, Fe, K, La, Na, Sb, Sc, Se and Zn determinations. The induced gamma activities of the standards and samples were measured using a gamma ray spectrometer coupled to an hiperpure Ge detector. For quality control of the results, IAEA- 85 Human Hair and INCT-TL-1 Tea Leaves certified reference materials (CRMs) were analyzed. Results obtained in these CRMs presented for most of elements, good agreement with the values of the certificates (relative errors less than 10%) and good precision (variation coefficients less than 13.6%). Results of replicate hair sample analysis showed good reproducibility indicating homogeneity of the prepared sample. Results obtained in the analyses of dyed and non-dyed hair

  3. Determination of minor-and trace elements in magnesite samples, by activation analysis

    International Nuclear Information System (INIS)

    Sepulveda Munita, C.J.A.

    1979-01-01

    A method employing activation analysis with thermal neutron was developed for the determination of minor and trace elements in magnesite samples from the states of Ceara and Bahia (Brazil). Ten samples were analyzed. A qualitative analysis of the samples indicated the presence of Mn, Fe, Sc, Ca, Cu, Co and some of the lanthanides. The experimental part includes a non-destructive analysis of manganese and analysis with chemical separation of the other elements, individually or in groups, after sample dissolution, The dissolutions were made with concentrated HCl and the further separations were carried out in 8 N HCl medium. Iron was separated by means of an extraction of HFeCl 4 with isopropyl ether. Scandium and calcium were determined by retention of scandium with di-(2-ehylhexyl) phosphoric acid (HDEHP). The activities of 46 Sc and 47 Sc (a 47 Ca descendant) were employed for the analysis of scandium and calcium in the sample. In the effluent of the kieselguhr column copper and cobalt were determined, after retention in an anionic resin of the CuCl - 3 and CoCl - 3 complexes. Finally, in the effluent of the resin, the lanthanide group was separated by oxalate precipitation. In the gamma-ray spectrum of this precipitate the elements europium, cerium, samarium and lanthanum were determined. A detailed study of the possible interferences in the neutron activation analysis of the elements analysed was also made. The precision and accuracy of the results obtained and the sensitivity of the method are discussed. (Author) [pt

  4. Radiochemical neutron-activation analysis of uncertified ultra-trace rare earth elements in two biological certified reference materials

    International Nuclear Information System (INIS)

    Cao, Lei; Tian, Weizhi; Ni, Bangfa; Wang, Pingsheng; Zhang, Yangmei

    2002-01-01

    Radiochemical neutron activation analysis (RNAA) has been used for the determination of eight rare earth elements (La, Ce, Nd, Sm, Eu, Tb, Yb, and Lu) in two Chinese certified reference materials (CRM), GBW 08503 (wheat powder) and GBW 09101 (human hair). These determinations are important for possible certification of the above mentioned ultra-trace elements, so far not certified. A simple one-step (REE)F 3 precipitation was used. Chemical yields were determined for all relevant elements by means of tracer experiments. The two CRM were also analyzed by inductively coupled plasma-mass spectrometry (ICP-MS) to compare the merits and drawbacks of these two major trace analytical techniques for these particular elements. RNAA was proven to be a reliable technique for ultra-trace analysis, especially in the certification of some ultra-trace elements. (orig.)

  5. Application of the neutron activation analysis technique in trace elements analysis

    International Nuclear Information System (INIS)

    Khamis, I.; Sarheel, A.; Al-Somel, N.

    2006-12-01

    The main objective in this study is the implementation k 0 -standardization method (single comparator method) using gold comparator as a routine method in neutron activation analysis laboratory in Engineering Nuclear Department. Cadmium ratio Rcd; Cd-ratio = [A s p/(A s p) C d] and the nuclear reactor constants (f=φ t h/φ e pi subcadimum thermal- to- epithermal neutron flux ratio and α with describing the φ e (E)∼ 1/E 1+α neutron flux distribution) were determined in the inner and outer irradiation sites at MNS Reactor. K 0 -IAEA software, which provided by the Agency, has been installed and applied in our laboratory. Trace elements in many kinds of samples (biological, environmental, alloy ...etc) were determined using K 0 -IAEA software. The results of standard reference materials (SRM's) obtained in this work show a good agreement with the certified values, and we got these results with a good accuracy closer to results which we got from relative NAA method. (author)

  6. Determination of trace elements in Turkish tea leaves by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Demiralp, R.

    1986-01-01

    The human body continuously assimilates a variety of inorganic elements from food and the environment. Some of these elements are closely related to human health and disorder. Tea is one of the most popular stimulating beverages which is consumed by low and high income family groups in many countries. Instrumental neutron activation analysis is one of the preferred methods because information on a large number of elements can be obtained simultaneously. Five packets each of the seven commonly used brands of tea were obtained from the market. In order to determine the transfer of trace elements into the drinkable portion about 2-3g. of the tea leaves were boiled in hot water for 2 min. After filtration the used tea leaves were dried at 65 deg. C in an oven and a portion, about 200mg was used for analysis. Samples and standards were irradiated 10 min. and 2 hrs. at pneumatic system and central thimble in the TRIGA MARK-II research reactor. After irradiation, the activities of samples and standards were measured with a aoaxial Ge detector coupled to a spectroscopic amplifier. A Canbera 90 model multi- channel analyzer with an 8K memory was used for pulse height analysis. The system has a resolution of 2.0 KeV. for the 1332.5 KeV gamma ray of 60 Co. The activity of the sample and standard was compared and the element contst of the sample was calculated. (author)

  7. Determination of trace elements of Egyptian crops by neutron activation analysis Pt. 3

    International Nuclear Information System (INIS)

    Sherif, M.K.; Awadallah, R.M.; Amrallah, A.H.

    1980-01-01

    Multielemental neutron activation analysis was used for the determination of Al, As, Au, Br, Ca, Cd, Co, Cr, Cu, Fe, La, Mn, Mo, Sb, Se, W and Zn in African tea and lady's fingers (Malvaceae Family), ginger (Zingiperanceae Family), canella bark (Laureceae Family), black pepper (Piperaceae Family), cucumber seeds and vegetable marrow seeds (Cucurbitaceae Family), tomatos seed (Solanaceae Family), safflower seeds (Compositae Family), jew's mallow seed (Tiliaceae Family) and sesame (Pedaliaceae Family). Trace elements determination was made for the analysis of destructive (using super pure nitric acid and adsorbing the metal-APDC and metal-Dz complexes on activated charcoal) and nondestructive (dry seeds) samples. The method is simple, precise and sensitive for the determination of microamounts of the elements (ppm to ppb). (author)

  8. Determination of trace elements in tea leaves by neutron activation analysis

    International Nuclear Information System (INIS)

    Kasrai, M.; Shoushtarian, M.J.; Bozorgzadeh, M.H.

    1977-01-01

    Instrumental neutron-activation analysis has been employed to determine 14 trace elements in two brands of Iranian and foreign tea. A popular local brand (Ghoncheh) and a foreign brand (Lipton tea bags) were randomly purchased. The samples were dried in an oven (100 deg C) and used without further treatment. In order to measure the concentration of elements in tea solution, weighed amounts of tea were mixed with double-distilled boiling water. After cooling the leaves were separated by centrifugation. Aliquots of clear solution were dried for analysis. Three sets of standards containing the following elements using the spec-pure materials were prepared: (a) Cl, Mn, Na, K; (b) Br, La, Au; (c) Cr, Fe, Rb, Sc, Cs, Zn, Co. In each irradiation, one set of standards, along with the sample, was neutron irradiated at a thermal flux of approximately 2x10 13 ncm -2 sec -1 in the Research Reactor of the Nuclear Research Centre. The period of irradiation ranged from 10 min to 4 hrs, depending on the radionuclides to be measured. The transference ratio of the elements into solution, when tea is leached by percolation, is also reported. It was found that some elements are totally transferred into solution and some are partially retained by the leaves. (T.G.)

  9. Trace element characterization of Indian vegetarian diet and its constituents by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Singh, V.K.N.; Garg, A.N.; Burte, P.P.

    1995-01-01

    Nutritive trace elements have been determined in a typical vegetarian diet and its various components. A hospital diet, pulses and vegetables have been characterised for 18 elements. Daily intake of elements have been compared with the International diet standards. (author). 5 refs., 1 tab

  10. Trace elements determinations in cancerous and non-cancerous human tissues using instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Choi, Insup.

    1989-01-01

    Recent improvements in analyzing techniques when coupled to the growing knowledge of trace element biochemistry provide a powerful tool to investigate the relationship between trace elements and cancer. It is hoped that selective delivery or restriction of specific minerals may aid in cancer prevention or treatment. Tissues were collected at the time of surgery of various cancer patients including colon cancer and breast cancer. Three kinds of tissues were taken from a patient; cancerous, noncancerous, and transitional tissue obtained from a region located between the cancer and healthy tissues. A total of 57 tissues were obtained from 19 cancer patients. Seven of them were colon cancer patients, and 5 of them were breast cancer patients. Nine elements were determined using instrumental activation analysis. Cancerous colon tissue had significantly higher concentrations of selenium and iron than healthy tissues. Cancerous breast tissue had significantly higher concentrations of selenium, iron, manganese, and rubidium than healthy tissues. Iron can be enriched in cancer tissue because cancer tissue retains more blood vessels. Selenium is enriched in cancer tissue, possibly in an effort of the body to inhibit the growth of tumors. The manganese enrichment can be explained in the same manner as selenium considering its suspected anticarcinogenicity. It is not certain why rubidium was enriched in cancer tissue. It could be that this is the result of alteration of cell membrane permeability, change in extracellular matrix, or increased metabolism in cancer tissue

  11. Analysis of Trace Elements in Rat Bronchoalveolar Lavage Fluid by Inductively Coupled Plasma Mass Spectrometry.

    Science.gov (United States)

    Qamar, Wajhul; Al-Ghadeer, Abdul Rahman; Ali, Raisuddin; Abuelizz, Hatem A

    2017-08-01

    The main objective was to determine the elemental profile of the lung lining fluid of rats which are used as model animals in various experiments. Lung lining fluid elemental constitution obtained after bronchoalveolar lavage fluid (BALF) was analyzed by inductively coupled plasma mass spectrometry (ICP-MS) to determine the biological trace elements along with calcium and magnesium. BALF was collected from healthy rats using a tracheal cannula. However, cells in BALF were counted to monitor any underlying inflammatory lung condition. Cell free BALF samples were processed and analyzed for the elements including magnesium (Mg), calcium (Ca), chromium (Cr), manganese (Mn), iron (Fe), nickel (Ni), copper (Cu), zinc (Zn), selenium (Se), bromine (Br), and iodine (I). In view of this, calcium concentration was the highest (6318.08 ± 3094.3 μg/L) and copper concentration was the lowest (0.89 ± 0.21 μg/L). The detected elements, from high to low concentration, include Ca > Mg > Fe > Br > I > Cr > Ni > Zn > Mn > Se > Cu. Pearson's correlation analysis revealed no significant correlation between cell count and concentration of any of the element detected in BALF. Correlation analysis also revealed significant positive correlation among Fe, I, Cr, Ni, and Mn. Ca was found to be correlated negatively with Cu and positively with Se. Br and Mg found to be positively correlated with each other. Zn remained the only element that was not found to be correlated with any of the elements in the rat BALF.

  12. Analysis of trace elements in scalp hair of mentally retarded children

    International Nuclear Information System (INIS)

    Man, C.K.; Zheng, Y.H.

    2002-01-01

    Hair samples of mildly mentally retarded (LR), moderately mentally retarded (MR), severely mentally retarded (SR) and normal children were collected and measured, using neutron activation analysis and X-ray fluorescence to determine the concentrations of Al, Sb, As, Ca, Cu, I, Fe Pb, Mg, Mn, Hg, K, Sr, S, V and Zn. The groups of children were of ages between 5 and 13. Difference in the mean concentration of each element between groups was tested by Student's t-test. No trend, either decreasing or increasing, has been established as the degree of severity increased from normal to SR children, except for the case of Cu. The present work may shed some light in the interpretation of findings on the effects of trace elements on neurobehavioral functions. (author)

  13. Application of micro-PIXE to fish life history analyses: trace element analysis of otoliths

    International Nuclear Information System (INIS)

    Elfman, M.; Limburg, K.E.; Kristiansson, P.; Malmqvist, K.; Pallon, J.

    1999-01-01

    Otoliths are biogenic, carbonate concretions which form part of the hearing/balance system in fishes. The radial growth of otoliths and the variation of trace elements along the radius appear to capture important aspects of fishes' environmental history. At the Lund Nuclear Microprobe Laboratory, we have begun to use Proton-Induced X-ray Emission spectroscopy (PIXE) for micro-elemental analysis of otoliths. The experimental procedure is discussed and a number of examples of what can be investigated are presented. In particular, movement of diadromous species (eel, menhaden, and anadromous brown trout) can be detected between fresh and brackish water by Sr/Ca ratio. This technique has also been used to identify fish that were raised in freshwater hatcheries and then released to brackish water (pike-perch example)

  14. Analysis of toxic trace elements in sea food samples by neutron activation

    International Nuclear Information System (INIS)

    Sarmani, S.; Majid, A.A.; Wood, A.K.; Hamzah, Z.

    1993-01-01

    The contents of toxic and essential trace element were analysed such as As, Hg, Se and Zn by neutron activation analysis in coastal fishes consumed by the general population of Malaysia. The mean values of the elements analysed expressed in mg/kg fresh weight ranged 1.42-5.61, 0.06-0.42, 4.2-20.6, 0.41-1.28 for As, Hg, Zn and Se, respectively. The maximum permissible limit for As in food was set at 1.0 mg/kg under the Malaysian Food Regulations. The results showed that consumption of coastal fishes is not permitted under the regulations, while the levels of Hg, Se and Zn were within the permissible limits. The daily dietary intake of As and Hg at 400 μg and 30 μg respectively are still within the tolerance levels. (author) 9 refs.; 2 tabs

  15. Neutron activation analysis in forensic investigations. Trace elements characterization of cigarettes

    International Nuclear Information System (INIS)

    Giordani, L.; Rizzio, E.; Brandone, A.

    2005-01-01

    Police investigations of the Italian Ministry of Treasury Police involving the illicit sale of tobacco lead to the confiscation of large quantities of smuggled cigarettes. Thousands of tons of cigarettes of different manufacturers are sequestrated yearly in many regions of Italy and different criminal organizations have been identified as unlawful importers. In order to verify whether the recovered smuggled lots of cigarettes come from the official manufacturers, or they have produced illicitly, usually chemical analysis are carried out. By the determination of trace elements content, specific information can be obtained by comparing different brands of cigarettes and different batches of tobacco. Samples of tobacco of cigarettes manufactured by the Italian State Monopoly, taken as 'reference samples', have been compared with those of illicit origin. Elements such as Co, Br, Cr and Sc have been found to be useful for the selective characterization. The results, submitted to statistical elaboration, provided important information on the origin of smuggled cigarettes. (author)

  16. Collection and preparation of bottom sediment samples for analysis of radionuclides and trace elements

    International Nuclear Information System (INIS)

    2003-07-01

    The publication is the first in a series of TECDOCs on sampling and sample handling as part of the IAEA support to improve reliability of nuclear analytical techniques (NATs) in Member State laboratories. The purpose of the document is to provide information on the methods for collecting sediments, the equipment used, and the sample preparation techniques for radionuclide and elemental analysis. The most appropriate procedures for defining the strategies and criteria for selecting sampling locations, for sample storage and transportation are also given. Elements of QA/QC and documentation needs for sampling and sediment analysis are discussed. Collection and preparation of stream and river bottom sediments, lake bottom sediments, estuary bottom sediments, and marine (shallow) bottom sediments are covered. The document is intended to be a comprehensive manual for the collection and preparation of bottom sediments as a prerequisite to obtain representative and meaningful results using NATs. Quality assurance and quality control (QA/QC) is emphasized as an important aspect to ensure proper collection, transportation, preservation, and analysis since it forms the basis for interpretation and legislation. Although there are many approaches and methods available for sediment analyses, the scope of the report is limited to sample preparation for (1) analysis of radionuclides (including sediment dating using radionuclides such as Pb-210 and Cs-137) and (2) analysis of trace, minor and major elements using nuclear and related analytical techniques such as NAA, XRF and PIXE

  17. Materials of the 3.Poznan analytical meeting: The novel methods of samples preparation and analysis of trace amounts of elements

    International Nuclear Information System (INIS)

    1994-01-01

    The conference on Novel Methods of Samples Preparation and Analysis of Trace Amounts of Elements was the eight of succeeding meetings organized annually since 1985 by the Committee of Analytical Chemistry of the Polish Academy of Sciences. The following groups of topics have been extensively discussed: accuracy and precision in trace amounts analysis, sample preparation methods, certification and application of standards and many other topics important for analytical chemistry of trace amount of different elements. Total 43 lectures have been presented in the course of meeting

  18. Elemental composition of platelets. Part I. Sampling and sample preparation of platelets for trace-element analysis

    International Nuclear Information System (INIS)

    Iyengar, G.V.; Borberg, H.; Kasperek, K.; Kiem, J.; Siegers, M.; Feinendegen, L.E.; Gross, R.

    1979-01-01

    Sampling of platelets for trace-element analysis poses special problems: obtaining adequate sample materials, achieving a sufficient cell purity, preserving viability (integrity), correcting for trapped plasma, and controlling contamination. We used a blood-cell separator for the primary isolation of platelets from blood, and differential centrifugation in natural plasma to further isolate them. The pyrimidopyrimidine RA233 was used as a stabilizer to maintain viability. 131 I-labeled human serum albumin was used to estimate trapped plasma. Contamination was controlled by using five-times-distilled water to simulate donor's blood in the system and by comparing three fractions: the serum, the first portion of the platelet-rich plasma, and the supernatant plasma after the final centrifugation. Neutron activation analysis was used for the elemental analysis. A single differential centrifugation of the platelet-rich plasma from the blood-cell separator at 400 x g for 8 min was optimum (mean mass fractions: erythrocytes/platelets < 5 mg/g and leukocytes/platelets < 20 mg/g). The trapped plasma in the wet platelet samples amounted to about 0.40 g/g. No appreciable contamination from the sampling system was found for the elements Ag, Cd, Co, Cr, Cs, Cu, Fe, Mo, Rb, Sb, Se, and Zn. 2 figures, 3 tables

  19. Determination of trace elements in drinking water by neutron activation analysis

    International Nuclear Information System (INIS)

    Munita, C.S.; Abe, R.M.; Andrade e Silva, L.G. de.

    1988-10-01

    The concentracao of Hg, Cr, Zn, Fe and Co has been determined in fresh drinking water by a combination of preconcentration and neutron activation analysis. In order to preconcentrate the trace metals, a Chelex-100 resin in the NH + - form has been employed and it was not necessary to use special NH 4 + - form has been employed and it was not necessary to use special agents for the adsorption of the elements which are practically quantitatively retained by the resin. The retention of each element during the preconcentration was investigated using radioactive tracers. Selenium is known as a strongly interferent element for the analysis since the (n,Π) produced 75 Se has a Π-line at 0.279 MeV which coincides with the only Π-line of 203 Hg. The separation was made by a selective retention of mercury. After the sample had passed through the resin, the column was transfered to a polythylene envelope and irradiated at a neutron flux of about 5.10 12 ncm -2 s -1 for 8 h. For Hg the resin was irradiated in quartz ampoules. The samples were counted 15 days after the irradiation. The present method is superior to most other Chelex-100 separation procesures where elements of interest are eluted from the resin prior determinations thereby introducing the possibility of additional reagent blanks and incomplete as well as non-reproducible recoveries. (author) [pt

  20. Ultra-sensitive trace element analysis of environmental samples using advanced TRXRF techniques

    International Nuclear Information System (INIS)

    Schwenke, H.; Knoth, J.; Michaelis, W.

    1980-01-01

    X-ray fluorescence analysis is a widely adopted technique for measuring elemental concentrations in a variety of sample species. The particular advantages compared to other methods are simplicity in instrumentation, rapidity of measurement and the high degree of automation attainable. In trace element analysis, however, the sensitivity of conventional x-ray fluorescence analysis is often insufficient. The paper describes a new type of energy-dispersive equipment which reveals ultimate performance with respect to detection limits and which thus considerably extends the applicability of XRF analysis. The essential feature of the system is the utilization of multiple total reflection (TR) of the exciting x-ray beam from polished quartz glass surfaces. Since the refractive index is slightly smaller than 1, total reflection occurs if the radiation strikes the surface at angles of less than 5'. The grazing incident beam from a fine-structure x-ray tube is twice reflected and follows a zigzag path before it is directed to the sample prepared as a thin film on the third quartz glass surface. The direct beam and scattered radiation are eliminated by diaphragms. In this way, a further reduction of the background in the fluorescence spectrum is achieved compared to a previously published version with single reflection of the exciting beam. The performance of the instrument leads to detection limits for aqueous solutions below 10 -11 g or 0.1 ppB, respectively, for at least 20 elements

  1. Multivariate statistical analysis to characterize/discriminate between anthropogenic and geogenic trace elements occurrence in the Campania Plain, Southern Italy.

    Science.gov (United States)

    Busico, Gianluigi; Cuoco, Emilio; Kazakis, Nerantzis; Colombani, Nicolò; Mastrocicco, Micòl; Tedesco, Dario; Voudouris, Konstantinos

    2018-03-01

    Shallow aquifers are the most accessible reservoirs of potable groundwater; nevertheless, they are also prone to various sources of pollution and it is usually difficult to distinguish between human and natural sources at the watershed scale. The area chosen for this study (the Campania Plain) is characterized by high spatial heterogeneities both in geochemical features and in hydraulic properties. Groundwater mineralization is driven by many processes such as, geothermal activity, weathering of volcanic products and intense human activities. In such a landscape, multivariate statistical analysis has been used to differentiate among the main hydrochemical processes occurring in the area, using three different approaches of factor analysis: (i) major elements, (ii) trace elements, (iii) both major and trace elements. The elaboration of the factor analysis approaches has revealed seven distinct hydrogeochemical processes: i) Salinization (Cl - , Na + ); ii) Carbonate rocks dissolution; iii) Anthropogenic inputs (NO 3 - , SO 4 2- , U, V); iv) Reducing conditions (Fe 2+ , Mn 2+ ); v) Heavy metals contamination (Cr and Ni); vi) Geothermal fluids influence (Li + ); and vii) Volcanic products contribution (As, Rb). Results from this study highlight the need to separately apply factor analysis when a large data set of trace elements is available. In fact, the impact of geothermal fluids in the shallow aquifer was identified from the application of the factor analysis using only trace elements. This study also reveals that the factor analysis of major and trace elements can differentiate between anthropogenic and geogenic sources of pollution in intensively exploited aquifers. Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. LASER SPECTROSCOPY AND TRACE ELEMENT ANALYSIS Chapter from the Energy and Environment Division Annual Report 1980

    Energy Technology Data Exchange (ETDEWEB)

    Various, Authors

    1981-05-01

    In order to control pollutants resulting from energy production and utilization, adequate methods are required for monitoring the level of various substances often present at low concentrations. The Energy and Environment Division Applied Research in Laser Spectroscopy & Analytical Techniques Program is directed toward meeting these needs, Emphasis is on the development of physical methods, as opposed to conventional chemical analysis techniques. The advantages, now widely recognized, include ultra-high sensitivity coupled with minimal sample preparation. In some instances physical methods provide multi-parameter measurements which often provide the only means of achiev·ing the sensitivity necessary for the detection of trace contaminants. Work is reported in these areas: APPLIED PHYSICS AND LASER SPECTROSCOPY RESEARCH; MICROPROCESSOR CONTROLLER ANODIC STRIPPING VOLTAMETER FOR TRACE METALS ANALYSIS IN WATER; THE SURVEY OF INSTRUMENTATION FOR ENVIRONMENTAL MONITORING; THE POSSIBLE CHRONDRITIC NATURE OF THE DANISH CRETACEOUS~TERTIARY BOUNDARY; IMPROVEMENT OF THE SENSITIVITY AND PRECISION OF NEUTRON ACTIVATION ANALYSIS OF SOME ELEMENTS IN PLANKTON AND PLANKTONIC FISH; and SOURCES OF SOME SECONDARILY WORKED OBSIDIAN ARTIFACTS FROM TIKAL, GUATEMALA.

  3. Sample preparation techniques in trace element analysis by X-ray emission spectroscopy

    International Nuclear Information System (INIS)

    Valkovic, V.

    1983-11-01

    The report, written under a research contract with the IAEA, contains a detailed presentation of the most difficult problem encountered in the trace element analysis by methods of the X-ray emission spectroscopy, namely the sample preparation techniques. The following items are covered. Sampling - with specific consideration of aerosols, water, soil, biological materials, petroleum and its products, storage of samples and their handling. Pretreatment of samples - preconcentration, ashing, solvent extraction, ion exchange and electrodeposition. Sample preparations for PIXE - analysis - backings, target uniformity and homogeneity, effects of irradiation, internal standards and specific examples of preparation (aqueous, biological, blood serum and solid samples). Sample preparations for radioactive sources or tube excitation - with specific examples (water, liquid and solid samples, soil, geological, plants and tissue samples). Finally, the problem of standards and reference materials, as well as that of interlaboratory comparisons, is discussed

  4. Applications of mass spectrometry in the trace element analysis of biological materials

    International Nuclear Information System (INIS)

    Moens, L.

    1997-01-01

    The importance of mass spectrometry for the analysis of biological material is illustrated by reviewing the different mass spectrometric methods applied and describing some typical applications published recently. Though atomic absorption spectrometry is used in the majority of analyses of biological material, most mass spectrometric methods have been used to some extent for trace element determination in biomedical research. The relative importance of the different methods is estimated by reviewing recent research papers. It is striking that especially inductively coupled plasma mass spectrometry is increasingly being applied, partly because the method can be used on-line after chromatographic separation, in speciation studies. Mass spectrometric methods prove to offer unique possibilities in stable isotope tracer studies and for this purpose also experimentally demanding methods such as thermal ionization mass spectrometry and accelerator mass spectrometry are frequently used. (orig.)

  5. Neutron activation analysis applied to the determination of trace elements in human nails

    International Nuclear Information System (INIS)

    Aguiar, Amilton Reinaldo

    2001-01-01

    There is a considerable interest in the determination of trace elements in human nails in order to use this tissue as a monitor of nutritional and healthy status of individuals, of occupational exposure diseases and of the environmental contamination. In this work, instrumental neutron activation analysis was applied to determine trace elements in finger nail clippings to make comparisons between the elemental concentrations obtained in nails from healthy individuals of a control group and those from cystic fibrosis (CF) patients. Firstly, a protocol for sample collection and preparation for analysis was established. Finger and toe nail samples from CF patients were collected at the Instituto da Crianca of Medicine School, University of Sao Paulo, SP. The nail samples from control group were collected from healthy adults and from children living in Sao Paulo city, SP. These samples were cleaned by stirring them witha a diluted Triton X100 solution and then by washing with distilled water and acetone. The analytical procedure consisted of irradiation nail samples and elemental standards in the IEA-R1m nuclear reactor under thermal neutro flux of about 10 12 n cm -2 s -1 , for short and long period irradiations. The activities of the radionuclides were measured using a gamma-ray spectrometer comprising an hyperpure Ge detector and associated electronic system. The biological reference materials Bovine Liver 1577b and Oyster Tissue 1566a, both from National Institute of Standards and Technology, USA were analysed in order to evaluate the accuracy and precision of the results. The analysis of variance (ANOVA) and F-test at the significance level of 5% were used to make a comparison between the sets of results obtained in this work. In the comparison of the results obtained for finger and toe nails from CF patients, the Br concentrations were higher in finger nails that those obtained for toe nails. For the control group of children, the finger nails presented different

  6. Application of neutron activation analysis to trace element determinations in lung samples

    International Nuclear Information System (INIS)

    Rocero, Sizue Ota

    1992-01-01

    The purpose of this work was to apply the instrumental neutron activation analysis method to determine trace elements in lung samples from smokers and non smokers. Samples of lung tissues and lymph nodes from pulmonary hilum analyzed were collected from autopsies by researchers from the Medicine College of the University of Sao Paulo, SP, Brazil. Adequate conditions for preparation and analysis of samples were previously established. The preparation of samples consisted of homogenization, lyophilization and sterilization in 60 Co source. The samples and standards were irradiated in the IEA-R1 reactor under thermal neutron flux of 3.7 x 10 11 n.cm -2 .s -1 for 30 min to determine Cl, K, Mn and Na and for 16 h under flux of 10 19 n.cm -2 .s -1 for the determination of Au, Br, Ce, Co, Cr, Cs, Eu, Fe, Hf, La, Rb, Sb, Sc, Se, Th and Zn. The counting were carried out with a hiperpure (ge) detector connected to a 4096 channels analyzer and a microcomputer. the results obtained for lung sample analyses indicated a good reproducibility of the method for most of the elements determined with relative standard deviations lower than 10.5%. The accuracy of the method was evaluated by analyzing reference materials such as IAEA Animal Muscle H-4, NIST Bovine Liver 1577a, IUPAC Bowen's Kale and NIES Vehicle Exhaust Particulates. The results obtained from these analyzes agreed with the values of the literature for several elements with relative errors less than 20%. Less precise and accurate results were obtained for elements with concentrations at the Mup/Kg levels. Elemental concentrations obtained in the lung tissue analyses were within the range of reference values for normal subjects presented in the literature, except for the Cl concentrations for non smokers, Hf in both groups and Sb for the smokers. By comparing results obtained for lung samples from smokers and non smokers, the concentrations of Ce, Cr and Sb were higher in lungs from smokers and the others elements were

  7. Determination of minor and trace elements in kidney stones by x-ray fluorescence analysis

    Science.gov (United States)

    Srivastava, Anjali; Heisinger, Brianne J.; Sinha, Vaibhav; Lee, Hyong-Koo; Liu, Xin; Qu, Mingliang; Duan, Xinhui; Leng, Shuai; McCollough, Cynthia H.

    2014-03-01

    The determination of accurate material composition of a kidney stone is crucial for understanding the formation of the kidney stone as well as for preventive therapeutic strategies. Radiations probing instrumental activation analysis techniques are excellent tools for identification of involved materials present in the kidney stone. In particular, x-ray fluorescence (XRF) can be very useful for the determination of minor and trace materials in the kidney stone. The X-ray fluorescence measurements were performed at the Radiation Measurements and Spectroscopy Laboratory (RMSL) of department of nuclear engineering of Missouri University of Science and Technology and different kidney stones were acquired from the Mayo Clinic, Rochester, Minnesota. Presently, experimental studies in conjunction with analytical techniques were used to determine the exact composition of the kidney stone. A new type of experimental set-up was developed and utilized for XRF analysis of the kidney stone. The correlation of applied radiation source intensity, emission of X-ray spectrum from involving elements and absorption coefficient characteristics were analyzed. To verify the experimental results with analytical calculation, several sets of kidney stones were analyzed using XRF technique. The elements which were identified from this techniques are Silver (Ag), Arsenic (As), Bromine (Br), Chromium (Cr), Copper (Cu), Gallium (Ga), Germanium (Ge), Molybdenum (Mo), Niobium (Nb), Rubidium (Rb), Selenium (Se), Strontium (Sr), Yttrium (Y), Zirconium (Zr). This paper presents a new approach for exact detection of accurate material composition of kidney stone materials using XRF instrumental activation analysis technique.

  8. Determination of arsenic and other trace elements in cosmetics by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Gonzalez Cepeda, A.M.; Cienfuegos Silva, E.E.

    1978-01-01

    A general survey of trace-elements in different types of cosmetics, in particular arsenic, was carried out in order to detect elements that might be detrimental to human health. The samples were analyzed by instrumental neutron activation analysis and high-resolution gamma-ray spectrometry with Ge(Li) detectors. Different amounts of Br and Sb, detected in almost all the samples, produced interferencies in the determination of As when the 559 KeV photopeak was used. Since the triplet formed could not be resolved by the Ge(Li) detector, a mathematical procedure was developed using the 776 KeV gamma-ray emission of 82-Br and various factors found experimentally. This procedure was checked using laboratory-made samples of known concentrations and the results obtained had good precision and accuracy. In addition to arsenic the elements Co, Cr, Br, Sc, Fe and Zn were also quantitatively determined. Those cosmetics made from inorganic raw materials have an As concentration higher than those elaborated from organic materials. (EC)

  9. Instrumental Neutron Activation Analysis of Trace Elements in Some Food Spices Consumed In Tehran, Iran

    Directory of Open Access Journals (Sweden)

    ali asghar fathivand

    2017-03-01

    Full Text Available Introduction There is a growing interest in determining the concentration of various elements in food spices. In the present study, the instrumental neutron activation analysis (INAA was employed to measure the trace elements in 11 commonly food spices consumed in Tehran, Iran. Materials and Methods The levels of K, Mn, Na, Cl, V, Br, Al, and As were determined and their effects on human health were discussed. The results were compared with the values reported in the literature. The accuracy and precision of the analytical procedure was estimated by analyzing the Lichen (IAEA-336 reference material. Results The concentrations of the measured elements in the spices were 3850-29157, 10-335, 153-2849, 186-3063, 0.2-2.8, 2.1-58.7, and 72-2102 ppm for K, Mn, Na, Cl, V, Br, and Al, respectively. As was only detected in thyme (0.8 ppm and plantain (0.42 ppm. Conclusion As the findings of the present study indicated, the concentrations of K and Na in the black pepper, garlic, and ginger were significantly higher than the values reported in other countries. The Mn levels in the black pepper and garlic consumed in Tehran were comparable with those in Poland. Furthermore, the concentration of As in these spices were lower than the maximum permissible limit.

  10. Analysis of trace element in intervertebral disc by Atomic Absorption Spectrometry techniques in degenerative disc disease in the Polish population

    Directory of Open Access Journals (Sweden)

    Andrzej Nowakowski

    2015-05-01

    Full Text Available Objective. Although trace elements are regarded crucial and their content has been determined in number of tissue there are only few papers addressing this problem in intervertebral disc in humans. Most of the trace elements are important substrates of enzymes influencing metabolism and senescence process. Others are markers of environmental pollution. Therefore the aim of the research was to analyzed of the trace element content in the intervertebral disc, which may be a vital argument recognizing the background of degenerative changes to be the effect of the environment or metabolic factors. Materials and methods. Material consist of 18 intervertebral disc from 15 patients, acquired in surgical procedure of due to the degenerative disease with Atomic Absorption Spectrometry content of Al, Cd, Co, Pb, Cu, Ni, Mo, Mg, Zn was evaluated. Results. Only 4 of the trace elements were detected in all samples. The correlation analysis showed significant positive age correlation with Al and negative in case of Co. Among elements significant positive correlation was observed between Al/Pb, Co/Mo, Al/Mg, Al/Zn Pb/Zn and Mg/Zn. Negative correlation was observed in Al/Co, Cd/Mg, Co/Mg, Mo/Mg, Co/Zn and Mo/Zn. Conclusions. This study is the first to our knowledge that profiles the elements in intervertebral disc in patients with degenerative changes. We have confirmed significant differences between the trace element contents in intervertebral disc and other tissue. It can be ground for further investigation.

  11. Determination of essential trace elements in wine by neutron activation analysis

    International Nuclear Information System (INIS)

    Daniele, Anna Paula

    2016-01-01

    Several studies have been carried out for determining essential elements in foodstuffs, including wine, due to its important nutritional role in human body functions. It was shown that daily consumption of wine in moderation contributes significantly to the needs of essential elements in human body such as Ca, Co, Cr, Fe, K, Mg, Mn, Zn, V, among others, and has health benefits in the prevention of numerous diseases and longer life expectancy, related in particular to the intake of antioxidants such as polyphenolic compounds. Trace elements are good indicators of origin of wines and their concentrations can be used as criteria to ensure authenticity, quality and show that the tolerance limits established by law were respected throughout the production process. However, although Brazilian wine industry is among the 15 largest in the world, analytical studies for organic and inorganic compounds of wine content are still small when compared to other major producers. In this sense, this study aimed to evaluate some procedures of wine sample preparation to determine essential elements by Instrumental Neutron Activation Analysis (INAA) and compare the results with those determined by Inductively Coupled Plasma Atomic Emission Spectrometry (ICP OES). Three sample preparation procedures were studied: freeze-drying, evaporation and dry ashing. The parameters studied were precision, accuracy and detection limit. ANOVA and Tukey-Kramer tests were applied to verify the statistical differences between the mean values obtained by the three wine preparation procedures for INAA with those means obtained by ICP OES. It was noticed that about 60% of results obtained by freeze-drying agreed with those obtained by ICP OES. (author)

  12. Proton induced X-ray emission analysis of trace elements in human blood serum

    International Nuclear Information System (INIS)

    Cheek, D.B.; Hay, H.J.; Newton, C.S.

    1979-01-01

    Proton induced x-ray emission has been used for quantitative analyses of trace elements in blood serum samples. This work is part of a survey concerned with Zn, Cu, Fe, Cr, Mn and Se in Australian Aboriginal people not receiving optimal diet. Special attention is being directed to Cr because of the high incidence of diabetes mellitus in these people

  13. Total reflection PIXE (TPIXE) and RBS for surface and trace element analysis.

    NARCIS (Netherlands)

    van Kan, J.A.; Vis, R.D.

    1996-01-01

    MeV proton and α beams at small incident angles (0-35 mrad) were used to analyse flat surfaces such as Si wafers and coated quartz substrates. X-rays and backscattered particles were detected in a total reflection geometry. Using TPIXE a quick and simultaneous detection of different trace elements

  14. Trace elemental analysis of drugs of abuse using synchrotron radiation total reflection X-ray fluorescence analysis (SR-TXRF).

    Science.gov (United States)

    Muratsu, Seiji; Ninomiya, Toshio; Kagoshima, Yasushi; Matsui, Junji

    2002-09-01

    Synchrotron radiation total reflection X-ray fluorescence spectroscopy (SR-TXRF) was utilized to analyze various trace elements in small amounts of drugs of abuse. Sample amounts of 1 microL solutions containing 10 microg of drugs (methamphetamine, amphetamine, 3,4-methylenedioxymethamphetamine, cocaine, and heroin) were spotted on silicon wafers for direct analysis. In addition, a leaflet of marijuana was set directly on a silicon wafer, and opium in the form of a soft lump was smeared on another silicon wafer for analysis. In these experiments, about 10 pg of contaminant elements could be detected. For example, in a seized methamphetamine sample, iodine was found, which could be indicative of synthetic route. In seized 3,4-methylenedioxymethamphetamine samples, variable amounts of phosphorus, calcium, sulfur, and potassium were found, which could not be detected in a control 3,4-methylenedioxymethamphetamine sample. For marijuana and opium, two spectral patterns were obtained that were far different from each other and could be easily discriminated. Using SR-TXRF, pg amounts of each trace element in 10 microg of various drugs can be easily detected, which is not the case either for a standard TXRF experimental system or for other elemental analysis techniques.

  15. Major and trace elements assessment in sediment from Ituparanga reservoir, by activation analysis and ICP OES

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Sharlleny A., E-mail: sharllenya@cetesbnet.sp.gov.br [Companhia de Tecnologia de Saneamento Ambiental (CETESB), Sao Paulo, SP (Brazil). Lab. de Quimica Inorganica; Bevilacqua, Jose Eduardo [Companhia de Tecnologia de Saneamento Ambiental (CETESB), Sao Paulo, SP (Brazil). Diretoria de Tecnologia, Qualidade e Avaliacao Ambiental; Favaro, Deborah I.T., E-mail: defavaro@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil). Lab. de Analise por Ativacao Neutronica

    2011-07-01

    The Ituparanga reservoir was built to generate electric power by the LIGHT Company and started its operation in 1912. It is fed by the Una, Sorocamirim and Sorocabucu rivers. This reservoir supplies water to a population of 600.000. This water system is affected by irregular soil occupation and urban development which has caught CETESB's (Environmental Company of Sao Paulo State) attention. In this study four geo-referenced sampling points were used and bottom sediment samples were collected. The sediment samples were dried at 400 deg C, ground in an agate mortar, sieved (200 mesh) and again homogenized. The instrumental neutron activation analysis was applied to the sediment samples in order to determine some major elements (Fe, K and Na), trace (As, Ba, Br, Co, Cr, Cs, Hf, Rb, Sb, Sc, Ta, Tb, Th, U and Zn) and rare earth (Ce, Eu, La, Lu, Nd, Sm, Tb and Yb) elements. By using ICP OES metals determination for Cd, Cr, Cu, Pb and Ni was undertaken after digestion procedure according to the 3051 method from US EPA. The methodology validation for precision and accuracy was carried out by reference material analyses. For metals Cd, Cr, Cu, Pb and Ni the concentration values were compared to the oriented values from Environmental Canada (TEL and PEL). The Enrichment Factor (EF) was calculated for sediment contamination assessment. (author)

  16. Studies of trace element determinations in nails by neutron activation analysis method

    International Nuclear Information System (INIS)

    Aguiar, Amilton Reinaldo; Saiki, Mitiko

    1996-01-01

    The purpose of this work was to develop the neutron activation analysis for trace element determinations in nails in order to apply this method to the study of the cystic fibrosis disease. It was verified that the elements Al, As, Br, Ca, Cd, Cl, Co, Cr, Cu, Fe, K, Mg, Mn, Na, Se and Zn can be determined by using short and long irradiations with thermal neutron flux from 10 11 to 10 13 n.cm -2 . -1 at the IEA-R1 nuclear research reactor. The washing solutions of triton-X100, NH 4 OH and acetone were tested in order to eliminate external contaminants from the nail samples. The nail analyses of the individual fingers from both of hands showed that the samples must be collected from all the fingers from both of hands to have a representative sample. The precision and the accuracy of the results were also examined by analyzing NIES 10C Rice Flour, IUPAC Bowen's Kale and NIST 1572 Citrus Leaves reference materials. (author)

  17. Trace elements in 11 fruits widely-consumed in the USA as determined by neutron activation analysis

    International Nuclear Information System (INIS)

    Michenaud-Rague, A.; Robinson, S.; Landsberger, S.

    2012-01-01

    While there is a lot of information on the elemental content of food for nutritional and pollution studies, the analysis of fruits has received little attention. We have investigated 11 commonly eaten fruits for their trace and minor element constituents by neutron activations including thermal and epithermal neutron activation analysis. Our results revealed that both blueberries and strawberries had the most of top two highest elemental concentrations followed by raspberries, oranges and mango. Bananas, grapes, plums, apples, pears, and cherries had the fewest or none of the most elevated elemental concentrations. (author)

  18. [Impact of specimen collection and storage consumable products on trace element quantitative analysis].

    Science.gov (United States)

    Song, Yan-shuang; Gu, Yong-en; Ba, Te; Zhai, Min; Pu, Ji; Shen, Zhen-lin; Tang, Shi-chuan; Jia, Guang

    2012-07-01

    This study aimed to explore the impact of specimen collection and storage consumable products on trace element quantitative analysis. Devices and consumable products of different brands used in specimen collection or storage were selected and treated separately as below:urine collection and storage tubes (Brand A, B, C and D, 2 samples for each brand) were treated with 1% of HNO(3) volume fraction for 2 - 4 h; blood taking device (Brand O, P and Q, 3 samples for each brand) were used for ultra-pure water samples collecting as simulation of blood sampling;dust sampling filters (Brand X, Y and Z, 2 samples for each brand) were cold digested by nitric acid for 12 h, followed by microwave digestion. Then cadmium, cobalt, chromium, copper, iron, manganese, molybdenum, nickel, lead, selenium, stannum, titanium, vanadium and zinc concentrations in the solutions obtained during the course of collect or storage were quantified by inductively coupled plasma mass spectrometer. For the urine collection and storage consumable products, background values of elements were described as mean of parellel samples. The consentration of 14 quantified elements were relatively low for 5 ml cryogenic vials (brand B) with background values range of 0.001 - 0.350 ng/ml. The background values of copper of 50 ml centrifuge tubes (brand A), chromium of 5 ml cryogenic vials (brand C) and zinc of 1.5 ml centrifuge tubes (brand D) were relatively high, which were 1.900, 1.095 and 1.368 ng/ml, respectively. Background values of elements in blood sampling devices were described as x(-) ± s. Background values of chromium for brand O, P and Q were (0.120 ± 0.017), (0.337 ± 0.093) and (0.360 ± 0.035) ng/ml; for copper were (0.050 ± 0.001), (0.017 ± 0.012) and (0.103 ± 0.015) ng/ml; for lead were (0.057 ± 0.072), (0.183 ± 0.118) and (0.347 ± 0.006) ng/ml; for titanium were (7.883 ± 0.145), (8.863 ± 0.190) and (8.613 ± 0.274) ng/ml; zinc were (2.240 ± 0.573), (42.140 ± 22.756) and (8

  19. [Particle Induced X-ray Emission (PIXE) for analysis of trace elements in biological materials].

    Science.gov (United States)

    Iwata, Y

    1996-01-01

    Outline of Particle Induced X-ray Emission (PIXE) and its application to biomedical samples are described. Charged particles from cyclotron or van de Graaff generator bombards analytical samples and semiconductor detector measures energy and intensity of induced characteristic x-ray. Simultaneous determination for 22Na to 92U is possible by PIXE. 100 nA of 3 MeV protons bombards biomedical samples and detection limits for almost all trace essential elements are sub microgram/g. Only 1 mg of biomedical sample is necessary for determination of trace elements and no chemical procedure is necessary for preparation of analytical sample. PIXE is powerful tool for determination of essential elements and applied for diagnosis for several diseases.

  20. Analysis of trace elements in the giant panda and arrow bamboo

    Science.gov (United States)

    Wang, Nengming; Chen, Suqing; Chen, Jianxuan; Zhang, Dazhong; Feng, Wenhe

    1987-04-01

    Trace elements from the giant panda including hair, liver, kidney, ovary and testis, were determined by PIXE. Comparative studies of the elemental contents in hair, liver and kidney from epileptic and normal giant pandas were performed respectively. The differences in the elemental contents of leaf, stalk, and bamboo shoots from normal and withered arrows were determined. For this research work a Van de Graaff electrostatic accelerator and a Si(Li) semiconductor spectrometer at the Institute of Nuclear Science and Technology of Sichuan University were employed.

  1. Analysis of Indian mint (Mentha spicata) for essential, trace and toxic elements and its antioxidant behaviour.

    Science.gov (United States)

    Choudhury, R Paul; Kumar, A; Garg, A N

    2006-06-07

    Mint, belonging to the genus Mentha in the family Labiatae (Lamiaceae) is pungent in taste with post digestive effects and hot potency. Ten samples of mint leaves, collected from four different locations in North-West parts of India (Roorkee, Dehradun, Baghpat and Uttarkashi) were analysed for seven minor (Al, Na, K, Ca, Cl, Mg, and P) and 20 trace (As, Au, Ba, Br, Co, Cr, Cs, Eu, Fe, Hf, Hg, La, Mn, Rb, Sb, Sc, Se, Sn, Th and Zn) elements by instrumental neutron activation analysis (INAA). Also Ni, Cu and Cd were determined by atomic absorption spectrophotometry (AAS). Samples along with reference materials (RMs) and synthetic primary standard were irradiated at approximately 10(13) n cm-2s-1 and its gamma-activity was measured using HPGe detector and MCA system. Most elements were found in widely varying amounts depending on the location, e.g. Na (0.21-0.86 mg/g), K (12.4-53.3 mg/g) and Ca (5.82-16.8 mg/g) whereas mean contents of other nutrient elements in mint were: Fe (108+/-22 microg/g), Mg (4.83+/-0.92 mg/g), Mn (53.5+/-9.6 microg/g), P (3.88+/-0.94 mg/g), Cu (16.9+/-1.8 microg/g), Zn (21.0+/-4.7 microg/g) and Se (0.18+/-0.03 microg/g). Further, DPPH free radical scavenging activity test in diethyl ether extract showed 100% activity at approximately 40 microg/L suggesting it to be antioxidant in accordance with literature reports.

  2. [Determination of polysaccharide from Chinese medicine Morinda officinalis how and its trace elements analysis].

    Science.gov (United States)

    Wu, Yong-Jun; Liu, Jie; Wu, Yu-Ming; Liu, Li-E; Zhang, Hong-Quan

    2005-12-01

    Polysaccharide was extracted from morinda officinalis how by back-flowing with 80% ethanol for 1 h, and the method of improved phenol-sulfuric acid spectroscopy was adopted to determine the content of morinda officinalis how polysaccharide. As for its trace elements, the atomic absorption spectroscopy was used to detect the content of Zn, Fe and Cu, which were compared with its fake; and cold atomic fluorometry was applied to determine the trace mercury. The results were satisfactory, which can give reference about the effective components of morinda officinalis how, and will help to exploit it.

  3. Distribution of Trace Elements in Core Marine Sediments of Coastal East Malaysia by Instrumental Neutron Activation Analysis

    International Nuclear Information System (INIS)

    Ashraf, Ahmadreza; Saion, Elias; Gharibshahi, Elham; Kamari, Halimah Mohamed; Yap, Chee Kong; Hamzah, Mohd Suhaimi; Elias, Md Suhaimi

    2017-01-01

    A study was carried out on the distribution and enrichment of trace elements in the core marine sediments of East Malaysia from three stations at South China Sea and one station each at Sulu Sea and Sulawesi Sea. Five stations of sediment cores were recovered and the vertical concentration profiles of six elements namely Br, Cs, Hf, Rb, Ta, and V were determined using the instrumental neutron activation analysis. The enrichment factor, geoaccumulation index and the modified degree of contamination were used to calculate the anthropogenic and pollution status of the elements in the samples. Except for Cs and Hf, which by the enrichment factor are categorized from minimum enrichment to moderate enrichment in all stations and for V and Rb in Sulu Sea and Sulawesi Sea, which are categorized minimum enrichment, other elements are found to be no enrichment at all stations. The geoaccumulation index of Hf in one station shows moderately polluted and for other elements are unpolluted. However, the modified degree values of all samples are less than 1, suggesting very low contamination of elements found in all the stations. - Highlights: • Measurement of trace elements distribution in the Malaysian East core marine sediment by INAA. • Standard reference materials were used as quality control of analytical procedure. • Assessment of pollution based on EF of related elements to the average shale. • Determine the contamination status of trace elements with the modified degree of contamination. • Evaluation of pollution status by I geo calculation.

  4. Trace elements and bone health.

    Science.gov (United States)

    Zofková, Ivana; Nemcikova, Petra; Matucha, Petr

    2013-08-01

    The importance of nutrition factors such as calcium, vitamin D and vitamin K for the integrity of the skeleton is well known. Moreover, bone health is positively influenced by certain elements (e.g., zinc, copper, fluorine, manganese, magnesium, iron and boron). Deficiency of these elements slows down the increase of bone mass in childhood and/or in adolescence and accelerates bone loss after menopause or in old age. Deterioration of bone quality increases the risk of fractures. Monitoring of homeostasis of the trace elements together with the measurement of bone density and biochemical markers of bone metabolism should be used to identify and treat patients at risk of non-traumatic fractures. Factors determining the effectivity of supplementation include dose, duration of treatment, serum concentrations, as well as interactions among individual elements. Here, we review the effect of the most important trace elements on the skeleton and evaluate their clinical importance.

  5. Trace element determination in fingernails, hair and blood serum in patients with Crohn's disease using neutron activation analysis

    International Nuclear Information System (INIS)

    Buschmann, H.

    1984-01-01

    The determination of trace elements and electrolyte concentrations in blood serum, hair and fingernails of 16 patients with Crohn's disease was carried out by means of instrumental neutron activation analysis. In the serum a significant decline in the zinc content could be registered, while the remaining trace elements remained in the normal range. The parenteral nutrition also showed a zinc deficiency. There was, however, also an iron deficiency. The studies of the hair and fingernails gave the following results: Rubidium and antimony in the normal range; zinc, selenium, iron and cobalt below normal values. (orig./PW) [de

  6. Santos estuarine sediments, Brazil - metal and trace element assessment by neutron activation analysis

    Energy Technology Data Exchange (ETDEWEB)

    Amorim, Eduardo P.; Favaro, Deborah I.T., E-mail: ducamorim@yahoo.com.b, E-mail: defavaro@ipen.b [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP) Sao Paulo, SP (Brazil); Berbel, Glaucia; Braga, Elisabete S., E-mail: edsbraga@usp.b [Universidade de Sao Paulo (USP), SP (Brazil). Inst. Oceanografico. Lab. de Nutrientes, Micronutrientes e Tracos nos Oceanos (LABNUT)

    2009-07-01

    The Santos estuary system is an intricate pattern of tidal channels and small rivers originating from the adjacent Pre-Cambrian slopes. These two major estuaries share a common area in the upper portion of the region which interacts with each other. The largest harbor in Latin America is located at the eastern outlet of the Santos estuary. This intricate and sensitive ecosystem is highly susceptible to human impact from industrial activities, urban sewage and polluted solid wastes disposal. Due to its high vulnerability CETESB (Environmental Control Agency of the Sao Paulo State) sporadically monitors the contamination levels of water, sediment and marine organisms in this region. The present study reports results concerning the distribution of some major, trace and rare earth elements in the Santos estuarine marine sediments. Thirty two bottom sediment samples (SS0601 to SS0616 (summer) and SW0601 to SW0616 (winter) were collected in this estuary, including regions of Sao Vicente, Santos, Cubatao and Vicente de Carvalho, by a vanVeen sampler in the summer and winter of 2006. Multielemental analysis was carried out by instrumental neutron activation analysis (INAA). The concentration values obtained for As and metals Cr and Zn in the sediment samples were compared to Canadian Council of Minister of the Environment (CCME) oriented values (TEL and PEL values) and are adopted by CETESB. (author)

  7. Santos estuarine sediments, Brazil - metal and trace element assessment by neutron activation analysis

    International Nuclear Information System (INIS)

    Amorim, Eduardo P.; Favaro, Deborah I.T.; Berbel, Glaucia; Braga, Elisabete S.

    2009-01-01

    The Santos estuary system is an intricate pattern of tidal channels and small rivers originating from the adjacent Pre-Cambrian slopes. These two major estuaries share a common area in the upper portion of the region which interacts with each other. The largest harbor in Latin America is located at the eastern outlet of the Santos estuary. This intricate and sensitive ecosystem is highly susceptible to human impact from industrial activities, urban sewage and polluted solid wastes disposal. Due to its high vulnerability CETESB (Environmental Control Agency of the Sao Paulo State) sporadically monitors the contamination levels of water, sediment and marine organisms in this region. The present study reports results concerning the distribution of some major, trace and rare earth elements in the Santos estuarine marine sediments. Thirty two bottom sediment samples (SS0601 to SS0616 (summer) and SW0601 to SW0616 (winter) were collected in this estuary, including regions of Sao Vicente, Santos, Cubatao and Vicente de Carvalho, by a vanVeen sampler in the summer and winter of 2006. Multielemental analysis was carried out by instrumental neutron activation analysis (INAA). The concentration values obtained for As and metals Cr and Zn in the sediment samples were compared to Canadian Council of Minister of the Environment (CCME) oriented values (TEL and PEL values) and are adopted by CETESB. (author)

  8. Development of a compact grazing exit X-ray fluorescence spectrometer for fast trace elemental analysis

    Energy Technology Data Exchange (ETDEWEB)

    Ashida, Takafumi, E-mail: ashidatakafumi@gmail.com; Tsuji, Kouichi

    2014-11-01

    A compact grazing exit X-ray fluorescence (GE-XRF) spectrometer was developed in the laboratory. An Al cylindrical collimator for the primary X-rays was placed just above the sample stage. This collimator also played the role of an exit slit to detect fluorescent X-rays at small grazing exit angles. Therefore, no additional exit slit was used in this setup, leading to a compact design. The entire size of the analysis equipment was 80 mm × 200 mm × 170 mm (horizontal × vertical × height). The maximum exit angle was adjusted to the height of the sample stage. The background was drastically reduced at grazing exit angles, enabling trace elemental analysis. A calibration curve was obtained using 10 μL Ga solutions. Accordingly, the detection limit for Ga was evaluated to be 20 ppb. - Highlights: • We developed a compact GE-XRF spectrometer. • The dimension of GE-XRF spectrometer was 80 mm × 200 mm × 170 mm. • A detection limit of 20 ppb for Ga was obtained. • Analytical performance was comparable with that of a table-top TXRF spectrometer.

  9. Mapping of Trace Elements in Coal and Ash Research Based on a Bibliometric Analysis Method Spanning 1971–2017

    Directory of Open Access Journals (Sweden)

    Liu Yang

    2018-02-01

    Full Text Available Coal is the most important fossil energy used in China. The environmental impact of trace elements released in coal combustion has become one of the hottest issues in recent years. Based on a software named CiteSpace, and social network analysis (SNA, a bibliometric analysis of research into trace elements in coal and ash field during 1971–2017 is presented with the information of authors, countries, institutions, journals, hot issues and research trends in the present study. The study results indicate that: (1 Shifeng Dai, Robert B Finkelman, Guijian Liu and James C Hower have a large number of publications with great influence. (2 China (29.8% and USA (22.2% have high productivity in total publications. China and the USA correlate closely in the cooperative web system. (3 China University of Mining and Technology and Chinese Academy of Sciences take the leading position in the quantity of publications among all research institutions. (4 Energy and fuels, engineering and environmental science are three disciplines with the most studies in this field. (5 International Journal of Coal Geology, Fuel, Energy and Fuels and Fuel Processing Technology are the top four journals with the most publications in this field. (6 The enrichment origin and modes of occurrence of trace elements are the mainstream research related to trace elements in coal and ash. The environmental problems caused by coal combustion have promoted the development of trace elements in coal research, and human health is getting more and more popular in recent years. The study findings provide a better understanding of features of trace elements in coal and ash research, which could be taken as a reference for future studies in this field.

  10. Minerals and trace elements determination in diets by neutron activation analysis

    International Nuclear Information System (INIS)

    Eiras, Maria Izabel O.; Favaro, Debora I.T.; Ribeiro, Marisilda; Cozzolino, Silvia M.F.

    2002-01-01

    In the present study 12 diets, each one consisting of a pool of seven day diets, composed by four meals: breakfast, lunch, dinner and snack, adequate in energy and macro nutrients according to the RDA (Recommended Daily Allowance) recommendations, were elaborated and offered to a group of 12 men (19-42 years). The diets were collected by duplicate portion technique and dried by two different processes: freeze drying and 60 deg C ventilated oven drying. In the total, 24 diets were analyzed. The content of some minerals and trace elements (Ca, Fe, Mg, Mn, Na, Se and Zn) were determined by Instrumental Neutron Activation Analysis. The validation of methodology was made by analysis of the reference materials Typical Diet (NIST SRM 1548 a ), Orchard Leaves (NIST SRM 1541) and Peach Leaves (NIST SRM 1547). The results observed by two different drying processes used were statistically compared by test T of Student. It was possible to conclude that the concentration means can be considered as statistically equal, within a significance level of 0.05. The daily intake values calculated from the concentration results were: 712 (± 59) mg Ca/day; 10.7 (± 0.8) mg Fe/ day; 3387 (± 16) mg K/ day; 275 (± 6) mg Mg/ day; 3.0 (± 0.5) mg Mn/ day; 3656 (± 699) mg Na/ day; 42 (± 6) μg Se/ day e 11.6 (± 2.4) mg Zn/ day. The calculated intake was compared to the new daily recommended values set by RDA (National Research Council-USA) for the range age of individuals studied. It was possible to conclude that the diets were adequate in Fe and Zn and inadequate for the other elements. Concerning the minerals Na and K we verified high daily intake levels and this was already observed in other Brazilian regional diets. (author)

  11. Application of a portable total reflection x-ray fluorescence spectrometer to a trace elemental analysis of wines

    International Nuclear Information System (INIS)

    Kunimura, Shinsuke; Kawai, Jun

    2009-01-01

    A portable total reflection X-ray fluorescence (TXRF) spectrometer has been applied to a trace elemental analysis of wines. Sulfur, K, Mn, Fe, and Rb were detected. These five elements were quantified by using 1 ppm of Co as an internal standard. The quantified concentrations ranged from sub-ppm to several hundred ppm. Because of organic substances in wines, the scattering of the incident X-rays from the dry residues of wines becomes strong. Therefore, a high spectral background appears in TXRF spectra of wines. Because of this background, relative standard deviations of the quantified concentrations were from 4 to 28%. Although the high spectral background appeared in the TXRF spectra of the wines, a detection limit down to several tens of ppb was achieved. The present portable spectrometer can be applied to screening for trace elements in wines before an accurate and precise analysis using a large elemental analyzer. (author)

  12. Evaluation of a tungsten coil atomization-laser-induced fluorescence detection approach for trace elemental analysis

    International Nuclear Information System (INIS)

    Ezer, Muhsin; Elwood, Seth A.; Jones, Bradley T.; Simeonsson, Josef B.

    2006-01-01

    The analytical utility of a tungsten (W)-coil atomization-laser-induced fluorescence (LIF) approach has been evaluated for trace level measurements of elemental chromium (Cr), arsenic (As), selenium (Se), antimony (Sb), lead (Pb), tin (Sn), copper (Cu), thallium (Tl), indium (In), cadmium (Cd), zinc (Zn) and mercury (Hg). Measurements of As, Cr, In, Se, Sb, Pb, Tl, and Sn were performed by laser-induced fluorescence using a single dye laser operating near 460 nm whose output was converted by frequency doubling and stimulated Raman scattering to wavelengths ranging from 196 to 286 nm for atomic excitation. Absolute limits of detection (LODs) of 1, 0.3, 0.3, 0.2, 1, 6, 1, 0.2 and 0.8 pg and concentration LODs of 100, 30, 30, 20, 100, 600, 100, 20, and 80 pg/mL were achieved for As, Se, Sb, Sn, In, Cu, Cr, Pb and Tl, respectively. Determinations of Hg, Pb, Zn and Cd were performed using two-color excitation approaches and resulted in absolute LODs of 2, 30, 5 and 0.6 pg, respectively, and concentration LODs of 200, 3000, 500 and 60 pg/mL, respectively. The sensitivities achieved by the W-coil LIF approaches compare well with those reported by W-coil atomic absorption spectrometry, graphite furnace atomic absorption spectrometry, and graphite furnace electrothermal atomization-LIF approaches. The accuracy of the approach was verified through the analysis of a multielement reference solution containing Sb, Pb and Tl which each had certified performance acceptance limits of 19.6-20.4 μg/mL. The determined concentrations were 20.05 ± 2.60, 20.70 ± 2.27 and 20.60 ± 2.46 μg/mL, for Sb, Pb and Tl, respectively. The results demonstrate that W-coil LIF provides good analytical performance for trace analyses due to its high sensitivity, linearity, and capability to measure multiple elements using a single tunable laser and suggest that the development of portable W-coil LIF instrumentation using compact, solid-state lasers is feasible

  13. Evaluation of a tungsten coil atomization-laser-induced fluorescence detection approach for trace elemental analysis.

    Science.gov (United States)

    Ezer, Muhsin; Elwood, Seth A; Jones, Bradley T; Simeonsson, Josef B

    2006-06-30

    The analytical utility of a tungsten (W)-coil atomization-laser-induced fluorescence (LIF) approach has been evaluated for trace level measurements of elemental chromium (Cr), arsenic (As), selenium (Se), antimony (Sb), lead (Pb), tin (Sn), copper (Cu), thallium (Tl), indium (In), cadmium (Cd), zinc (Zn) and mercury (Hg). Measurements of As, Cr, In, Se, Sb, Pb, Tl, and Sn were performed by laser-induced fluorescence using a single dye laser operating near 460 nm whose output was converted by frequency doubling and stimulated Raman scattering to wavelengths ranging from 196 to 286 nm for atomic excitation. Absolute limits of detection (LODs) of 1, 0.3, 0.3, 0.2, 1, 6, 1, 0.2 and 0.8 pg and concentration LODs of 100, 30, 30, 20, 100, 600, 100, 20, and 80 pg/mL were achieved for As, Se, Sb, Sn, In, Cu, Cr, Pb and Tl, respectively. Determinations of Hg, Pb, Zn and Cd were performed using two-color excitation approaches and resulted in absolute LODs of 2, 30, 5 and 0.6 pg, respectively, and concentration LODs of 200, 3000, 500 and 60 pg/mL, respectively. The sensitivities achieved by the W-coil LIF approaches compare well with those reported by W-coil atomic absorption spectrometry, graphite furnace atomic absorption spectrometry, and graphite furnace electrothermal atomization-LIF approaches. The accuracy of the approach was verified through the analysis of a multielement reference solution containing Sb, Pb and Tl which each had certified performance acceptance limits of 19.6-20.4 microg/mL. The determined concentrations were 20.05+/-2.60, 20.70+/-2.27 and 20.60+/-2.46 microg/mL, for Sb, Pb and Tl, respectively. The results demonstrate that W-coil LIF provides good analytical performance for trace analyses due to its high sensitivity, linearity, and capability to measure multiple elements using a single tunable laser and suggest that the development of portable W-coil LIF instrumentation using compact, solid-state lasers is feasible.

  14. Trace element analysis of old exposed air filters: a feasibility study

    International Nuclear Information System (INIS)

    Pattenden, N.J.; Fisher, E.M.R.; Bones, E.M.

    1979-10-01

    A limited number of old exposed air filters from a network of sampling stations extending the length of North and South America have been analysed for many trace elements. (The network is run by the United States Department of Energy Environmental Measurements Laboratory). The objective was to assess the possible value of a large program of such measurements for providing information on the trace element concentrations in airborne particulates existing at the time of sample collection. On the basis of the evidence obtained, it is considered that valid information could be extracted in this way. In view of the extent of the store of old filters, which cover about a 10 year period up to the present day from stations spread over the North and South American continents and elsewhere, such a program appears to be well worthwhile. (author)

  15. Analysis of trace elements responsible for antioxidant protection by SRXFA method

    Science.gov (United States)

    Gonchar, A.; Kolmogorov, Yu; Dikalova, A.; Yelinova, V.; Kondratev, V.

    2001-09-01

    The possibilities of using the energy dispersion synchrotron radiation X-ray fluorescence analysis (SRXFA) for control of blood plasma and liver trace element (TE) content in rats with hyperproduction of oxygen radicals and hair TE content in women with mammary hyperplasia and cancer are demonstrated. Our data show that activity of antioxidant enzymes superoxide dismutase (SOD) and catalase in the blood and liver depends on the amount of TE incorporated into the structure of the active center of these enzymes, which are responsible for antioxidant protection. A decrease of activity of these enzymes is accompanied by an increase of production of free OH radicals in the tissues. Clinical data demonstrated that scalp hair of patients with oncological mammary pathology was characterized by a significant decrease of concentrations of selenium (Se) and zinc (Zn) and by an increase of chromium (Cr). The Se deficit was more pronounced in patients with cancer than in those with mammary hyperplasia ( p<0.05). The SRXFA method permits one to carry out a controllable correction of TE imbalance in many diseases whose development is caused by oxygen radical injury.

  16. Mesh Refinement in Finite Element Analysis by Minimization of the Stiffness Matrix Trace

    Science.gov (United States)

    1989-11-01

    preceed the last card "CEND" in the Executive Control Deck. The following set of DMAP instructions were used in the trace calculations: Nastran Executive...3 edges. NASTRAN MSGMESH t , GIFTSc , SUPERSAP. and SUPARTABt (in I-DEAS) have this capability. For a more complicated geometry Schwarz-Christoffel...distortion factors of the elements. t NASTRAN MSGMESH is developed by MacNeal-Schwendler Corporation C) GIFTS is developed by Sperry Univac Computer System

  17. Nuclear techniques for trace element analysis. PIXE and its applications to biomedical samples

    International Nuclear Information System (INIS)

    Cata-Danil, I.; Moro, R.; Gialanella, G.

    1996-01-01

    Problems in understanding the role of trace elements in the functioning of life processes are discussed. A brief review of the state of the PIXE technique is given. Principles and recent advances in beam systems, instrumentation and sample handling are covered. A rather comprehensive list of references regarding varies methodological aspects and biomedical applications is given. Some applications are discussed. In particular, preliminary results of an investigation regarding pediatric obesity are presented. (author) 5 tabs., 21 refs

  18. Trace elements in brazilian soils

    International Nuclear Information System (INIS)

    Rocha, Geraldo Cesar

    1995-01-01

    A literature revision on trace elements (Zn, B, Mn, Mo, Cu, Fe, and Cl) in Brazilian soils was prepared, with special attention to the chemical form and range in the soil, extraction methods and correlation of the amount in soils with soil properties

  19. Determination of trace elements and heavy metals in the Zarka River sediments by instrumental neutron activation analysis

    Science.gov (United States)

    Al-Jundi, J.

    2000-09-01

    Instrumental neutron activation analysis (INAA) technique was employed to analyze the sediments from several sites along the Zarka River (Jordan). Measurements of heavy and trace metals in the river are reported. The results show that the concentration of the elements is site dependent. Almost all the toxic and trace elements show a high level concentration in certain sites. The data suggest that an anthropogenic input into the river for elements such as Zn, Cr, As, V, Co and Zr occurred. These elements, however, found their ways into the river from different sources. The main sources were the presence of textile, paint and tier plants, in addition to the waste sewage discharges and water treatment stations.

  20. Trace element analysis of the scalp hair from pregnant women by PIXE

    International Nuclear Information System (INIS)

    Zeng Xianzhou; Yao Huiying; Yuan Aina; Zhao Huiyang

    1986-01-01

    On the basis of a self-comparison method for each individual, a study on the changes of the elemental concentrations in the scalp hair from pregnant women before and after childbirth was made by PIXE. The hair samples were collected from 10 young mothers about 3 months after the delivery of their first child. In the control group, the hair samples from 11 normal girls were collected and analyzed in the same manner. Experimental results show that no significant changes of the trace element Cu and Zn concentrations in the hair correlated with pregnancy were observed while remarkable changes in the Ca, Fe and Mn concentrations in the hair before and after delivery were found. These results were compared with previously published data on the changes of the corresponding elements during pregnancy in serum

  1. PM2.5 in Urban and Rural Nursery Schools in Upper Silesia, Poland: Trace Elements Analysis

    Directory of Open Access Journals (Sweden)

    Anna Mainka

    2015-07-01

    Full Text Available Indoor air quality (IAQ in nursery schools is an emerging public health challenge. Particular attention should be paid to younger children, because they are more vulnerable to air pollution than older children. Among air pollutants, fine particulate matter (PM2.5 is of the greatest interest mainly due to its strong association with acute and chronic effects on children’s health. In this paper, we present concentrations of PM2.5 and the composition of its trace elements at naturally ventilated nursery schools located in the area of Gliwice, Poland. The nursery schools were selected to characterize areas with different degrees of urbanization and traffic densities during the winter and spring seasons. The results indicate there is a problem with elevated concentrations of PM2.5 inside the examined classrooms. The children’s exposure to trace elements was different based on localization and season. PM2.5 concentration and its trace element composition have been studied using correlation coefficients between the different trace elements, the enrichment factor (EF and principal component analysis (PCA. PCA allowed the identification of the three components: anthropogenic and geogenic sources (37.2%, soil dust contaminated by sewage sludge dumping (18.6% and vehicular emissions (19.5%.

  2. Comparative trace elemental analysis of cancerous and non-cancerous tissues of rectal cancer patients using PIXE

    Science.gov (United States)

    Naga Raju, G. J.; Sarita, P.; Murthy, K. S. R.

    2017-08-01

    Particle Induced X-ray Emission (PIXE), an accelerator based analytical technique has been employed in this work for the analysis of trace elements in the cancerous and non-cancerous tissues of rectal cancer patients. A beam of 3 MeV protons generated from 3 MV Pelletron accelerator at the Ion Beam Laboratory of Institute of Physics, Bhubaneswar, India was used as projectile to excite the atoms present in the tissues samples. PIXE technique, with its capability to detect simultaneously several elements present at very low concentrations, offers an excellent tool for trace element analysis. The characteristic X-rays emitted by the samples were recorded by a high resolution Si (Li) detector. On the basis of the PIXE spectrum obtained for each sample, the elements Cl, K, Ca, Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, As, and Br were identified and their relative concentrations were estimated in the cancerous and non-cancerous tissues of rectum. The levels of Mn, Fe, Co, Cu, Zn, and As were higher (p cancer tissues relative to the normal tissues. The alterations in the levels of the trace elements observed in the present work are discussed in this paper with respect to their potential role in the initiation, promotion and inhibition of cancer of the rectum.

  3. Trace elements in wine and other beverages

    International Nuclear Information System (INIS)

    Eschnauer, H.

    1974-01-01

    Survey of the mostly physical methods of analysis (e.g. activation analysis) for the dectection of trace elements in wine and in other alcoholic and non-alcoholic beverages as well as for detection of radioactivity (natural and man-made) in these beverages. (HP) [de

  4. Temporal and spatial trends studied by lichen analysis: atmospheric deposition of trace elements in Mexico

    Energy Technology Data Exchange (ETDEWEB)

    Aspiazu, J.; Cervantes, L.; Ramirez, J.; Lopez, J.; Villasenor, P. [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico); Ramos, R.; Munoz, R. [Secretaria del Medio Ambiente, Gestion Ambiental del Aire, Mexico City (Mexico)

    2007-07-01

    Ball moss on Tillandsia recurvata (Bromeliaceae), collected in an area previously identified as unpolluted, was transplanted to thirteen bio-monitoring sites in the downtown and metropolitan areas of Mexico City (which cover a surface of 9,560 km{sup 2}) during the periods August 2002 - January 2003 and July 2003 - October 2003. A total of 52 lichens (weighing 300 g) were transplanted to each place. Two were analysed as zero or reference, El Chico National Park, a location 100 Km upwind from the city and the remaining 26 were hung in nylon net bags in order to be able to collect two transplanted tree month, out of every season over a one-year period. The concentrations were measured by the quantitative PIXE method based on an extemal beam facility. The atmospheric deposition for trace elements was inferred by its concentration in lichen samples collected in 2002 from 13 sites in Mexico and compared with data from a similar survey in 2003. The concentration of Cr, Cu, Co, Fe, Mn, Ni, Pb and Zn and other elements was determined for each sample. Maps for each element were drawn after a geostatistical estimate of the metal concentration in the sample was made. Maps were drawn for all elements with the estimated values. Geographical distribution patterns were obtained for the different metals, reflecting the contribution of natural and anthropogenic emission sources. The deposition patterns of V, As, Se, Cd and Pb are substantially influenced by long-range transport from other parts of Mexico City. For Cr, Fe, Co, Ni, and Cu, the deposition patterns are largely determined by contribution from point sources within Mexico and in the metropolitan area. The lichen data for Br and, in part, Se reflect an airborne supply from the environment. Contributions to trace element concentrations in lichen sources other than atmospheric deposition are identified and discussed. The Spatial and temporal variations in the distribution of metal concentration are discussed. (Author)

  5. Temporal and spatial trends studied by lichen analysis: atmospheric deposition of trace elements in Mexico

    International Nuclear Information System (INIS)

    Aspiazu, J.; Cervantes, L.; Ramirez, J.; Lopez, J.; Villasenor, P.; Ramos, R.; Munoz, R.

    2007-01-01

    Ball moss on Tillandsia recurvata (Bromeliaceae), collected in an area previously identified as unpolluted, was transplanted to thirteen bio-monitoring sites in the downtown and metropolitan areas of Mexico City (which cover a surface of 9,560 km 2 ) during the periods August 2002 - January 2003 and July 2003 - October 2003. A total of 52 lichens (weighing 300 g) were transplanted to each place. Two were analysed as zero or reference, El Chico National Park, a location 100 Km upwind from the city and the remaining 26 were hung in nylon net bags in order to be able to collect two transplanted tree month, out of every season over a one-year period. The concentrations were measured by the quantitative PIXE method based on an extemal beam facility. The atmospheric deposition for trace elements was inferred by its concentration in lichen samples collected in 2002 from 13 sites in Mexico and compared with data from a similar survey in 2003. The concentration of Cr, Cu, Co, Fe, Mn, Ni, Pb and Zn and other elements was determined for each sample. Maps for each element were drawn after a geostatistical estimate of the metal concentration in the sample was made. Maps were drawn for all elements with the estimated values. Geographical distribution patterns were obtained for the different metals, reflecting the contribution of natural and anthropogenic emission sources. The deposition patterns of V, As, Se, Cd and Pb are substantially influenced by long-range transport from other parts of Mexico City. For Cr, Fe, Co, Ni, and Cu, the deposition patterns are largely determined by contribution from point sources within Mexico and in the metropolitan area. The lichen data for Br and, in part, Se reflect an airborne supply from the environment. Contributions to trace element concentrations in lichen sources other than atmospheric deposition are identified and discussed. The Spatial and temporal variations in the distribution of metal concentration are discussed. (Author)

  6. Extractable sulphate-sulphur, total sulphur and trace-element determinations in plant material by flow injection analysis

    Energy Technology Data Exchange (ETDEWEB)

    Heanes, D.L. (South Australian Department of Agriculture, Adelaide (Australia))

    1990-01-01

    A rapid, accurate and reproducible procedure for determining total sulphur(S) and trace elements (copper, zinc, manganese and iron) in plant material is described. Plant material is digested in culture tubes with a mixture of nitric and perchloric acids containing ammonium metavanadate and calcium chloride. In the acid digest, concentrations of total-S as sulphate are determined by turbidimetry and trace-elements by flame atomic absorption spectrophotometry using flow injection analysis. The results for a range of plant materials compare well with those obtained by conventional procedures for the same elements. The microprocessor controlled digestion and multielement assay procedure described here offers improved laboratory efficiencies in materials, time and cost effectiveness. The techniques should be particularly useful when plant tissues are in limited supply.

  7. Trace element analysis of mineral water samples by PIXE and ICP-MS

    International Nuclear Information System (INIS)

    Kennedy, V.John; Augusthy, A.; Varier, K. M.; Magudapathy, P.; Panchapakesan, S.; Nair, K.G.M.

    1998-01-01

    Trace elements present in bottled mineral water have been studied by PIXE and ICP-MS. Samples from ten different brands of brands of bottled mineral water were prepared by preconcentration techniques. Measurements were carried out using the 2 MeV proton beam obtained from 3 MV Tandem pelletron accelerator at the Institute of Physics, Bhubaneswar. Our results are compared with Indian standard packaged natural mineral water specifications, World Health Organisation (WHO) and European guidelines for drinking water standards. Concentration of aluminum was found to be more in one of the brands. In general, our results are comparable to the above standards. (author)

  8. Trace elemental characterisation of different Indian tea samples by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Lagad, Rupali A.; Alamelu, D.; Aggarwal, S.K.; Acharya, R.

    2010-01-01

    Determination of elemental content of different food materials is of importance since excess or deficiency of some of the elements have direct consequence to health of human beings. Tea is a common beverage consumed widely in India. India is one of the major country where good quality tea is produced. The tea plants are grown over a wide region of the country. It was of interest to study the elemental composition in tea samples from different geographical locations and to develop a suitable methodology to identify the geographical origin from the trace element profiles. With this objective, about 40 tea samples (both from plantations as well as from market) from the different locations in India viz. Assam, Munnar, Himachal Pradesh and Darjeeling were analyzed by INAA. About 150 mg of each of the sample packed in aluminium foil was irradiated in the self serve position of CIRUS reactor, BARC, for 3 to 5 hours at a neutron flux of ∼10 13 cm -2 s -1 . Along with the samples, Certified Reference Materials (CRMs) GBS-7(Tea leaves, as reference standard) and SRM-1515 (Apple leaves as control sample) were irradiated. Radioactive assay of the irradiated samples were carried out using a 40% relative efficiency HPGe detector coupled to 8K MCA and gamma-ray spectra were recorded for sufficient time for obtaining good counting statistics. Peak areas were determined using a peak-fit software PHAST. Concentrations of the different elements in tea samples were determined using relative method of INAA

  9. Evaluation of essential trace elements in preterm and full term milk and childhood formulas by neutron activation analysis

    International Nuclear Information System (INIS)

    Santos, Paola de Souza

    2009-01-01

    Many studies have emphasized the need of trace elements during infancy and their adequate availability in human milk. Deficiency of minor and trace elements can lead to various disorders in infants. During early childhood trace element requirements, are more critical due to faster growth rates. In this study, Ca, Cl, Fe, K, Mg, Mn, Na, Se and Zn were determined in human colostrum samples from mothers of preterm and full-term newborns. Samples were collected by manual expression from the first to the fifth day after birth. After collection, human colostrum samples were frozen and freeze-dried for analyses. Few of the most commonly commercialized were also analyzed. The essential element concentrations were determined in 30 colostrum samples and 17 milk formula brands by Instrumental Neutron Activation Analysis. Multivariate analyses were applied and the results were separated in two clusters. However the separation was not related to the corresponding gestational age. Results of this study showed that the concentration levels of the essential element Ca, K and Na in the milk formula samples analyzed were in agreement with the printed information on the labels. All concentration levels were also within ANVISA and Codex Allimentarius recommended values and thus adequate for infant nutritional needs. (author)

  10. Brain trace elements and aging

    International Nuclear Information System (INIS)

    Hebbrecht, Geert; Maenhaut, Willy; Reuck, Jacques de

    1999-01-01

    Degenerative mechanisms involved in the aging process of the brain are to a certain extent counteracted by repair mechanisms. In both degenerative and recovery processes, trace elements are involved. The present study focused on the role of two minor (i.e., K and Ca) and six trace elements (i.e., Mn, Fe, Cu, Zn, Se and Rb) in the aging process. The elements were determined by PIXE in cerebral cortex and white matter, basal ganglia, brainstem and cerebellar cortex of 18 postmortem human brains, from persons without a history of neurologic or psychiatric disease who deceased between the age of 7 and 79. This age range allowed us to study the relationship between elemental concentrations and age. The most prominent findings were a concentration decrease for K and Rb and a concentration increase for the elements Ca, Fe, Zn and Se. The study supports recent findings that Ca and Fe are involved in brain degenerative processes initiated by oxygen free radicals, whereas Zn and Se are involved in immunological reactions counteracting the aging process

  11. Trace element analysis of the Otani Collection's Dunhuang and Turfan manuscripts by PIXE

    Energy Technology Data Exchange (ETDEWEB)

    Kohno, M.; Yoshida, K.; Moritani, K.; Norizawa, K. [Department of Nuclear Engineering, Kyoto Univ., Sakyo, Kyoto (Japan); Enami, K.; Kasajima, H. [Ryukoku Univ., Department of Mechanical and System Engineering, Otsu, Shiga (Japan); Ueyama, D. [Ryukoku Univ., Faculty of Intercultural Communication, Otsu, Shiga (Japan); Takada, J.; Matsushita, R. [Kyoto Univ., Kumatori, Osaka (Japan). Research Reactor Inst

    1999-07-01

    In order to classify the Otani Collection's Dunhuang and Turfan manuscripts, their trace elements were analyzed by PIXE. The paper samples of these manuscripts were fallen off when they were photographed for a CD-ROM catalog. These samples were very small and their size was less than several millimeters. In addition, some paper fragments dating from the late Edo-era of Japan and the late Qing Dynasty of China, and modern Japanese handmade paper were analyzed using PIXE and NAA. Quite interesting results were obtained when analyzing the trace elements - Na, Mg, Al, Si, S, Cl, K, Ca, Sc, Mn, Fe, Cu, Zn, As, Br, Sr, Ba, Pb, La, Sm. It was found that Dunhuang and Turfan papers of the Otani Collection were characterized by its highest iron and bromine content. The reason of the highest iron content probably originates in their making process and/or depends on their preservative environment. On the other hand, it became clear as for the highest bromine content that the origin is from fumigation of methyl bromide. (author)

  12. Simple approach to sediment provenance tracing using element analysis and fundamental principles

    Science.gov (United States)

    Matys Grygar, Tomas; Elznicova, Jitka; Popelka, Jan

    2016-04-01

    Common sediment fingerprinting techniques use either (1) extensive analytical datasets, sometimes nearly complete with respect to accessible characterization techniques; they are processed by multidimensional statistics based on certain statistical assumptions on distribution functions of analytical results and conservativeness/additivity of some components, or (2) analytically demanding characteristics such as isotope ratios assumed to be unequivocal "labels" on the parent material unaltered by any catchment process. The inherent problem of the approach ad (1) is that interpretation of statistical components ("sources") is done ex post and remains purely formal. The problem of the approach ad (2) is that catchment processes (weathering, transport, deposition) can modify most geochemical parameters of soils and sediments, in other words, that the idea that some geochemistry parameters are "conservative" may be idealistic. Grain-size effects and sediment provenance have a joint influence on chemical composition of fluvial sediments that is indeed not easy to distinguish. Attempts to separate those two main components using only statistics seem risky and equivocal, because grain-size dependence of element composition is nearly individual for each element and reflects sediment maturity and catchment-specific formation transport processes. We suppose that the use of less extensive datasets of analytical results and their interpretation respecting fundamental principles should be more robust than only statistic tools applied to overwhelming datasets. We examined sediment composition, both published by other researchers and gathered by us, and we found some general principles, which are in our opinion relevant for fingerprinting: (1) Concentrations of all elements are grain-size sensitive, i.e. there are no "conservative" elements in conventional sense of provenance- or transport-pathways tracing, (2) fractionation by catchment processes and fluvial transport changes

  13. Neutron activation analysis of trace metallic elements eluted from molecular sieves in the dehydration process of safflower oil

    International Nuclear Information System (INIS)

    Takasago, Masahisa; Kobayashi, Koichi; Taru, Yasunori; Takaoka, Kyo

    1992-01-01

    Dissolved water in safflower oil affects the autoxidation of this oil significantly. Molecular sieves were used to remove the dissolved water from the oil. This method is much simpler than that of distillation, and dissolved water can be removed to the same extent as that by distillation. But, due to the elution of many kinds of trace metallic elements in the oil dehydrated with molecular sieves, these elements were analyzed by neutron activation analysis. For a data comparison trace amounts of metallic elements in the oil dehydrated by distillation were also analyzed. Since the intensity of the γ ray-photoelectric peak of nuclide 28 Al was largest among the detected elements, this element was analyzed quantitatively and the other elements qualitatively. In safflower oil dehydrated with molecular sieves, 14 kinds of the elements (I, Br, Al, Mg, Si, V, Cl, Nd, Ta, Cr, Sb, Cs, Co, Na) were detected. Also, I, Br, Cl, Cr, Ta, Sb, and Al elements were detected in the oil dehydrated by distillation. The intensity of the photoelectric peak of nuclide except 28 Al was essentially the same as that in the oil dehydrated by distillation, but the intensity of 28 Al in the oil with molecular sieves was about 28 times stronger than that in distillation oil. In the molecular sieves, 19 impure elements in addition to the original constituents (Na, K, Al, si, O) were detected. It was Al, Na, Si, Nd, Cs, and Co along with impure elements may possibly have been eluted in the oil. Al element in safflower oil dehydrated with molecular sieves was analyzed quantitatively. 0.91 ppm of Al was detected in safflower oil. The eluted amount of Al in safflower oil dehydrated by distillation was 0.032 ppm. A larger amount of Al element was thus eluted into the oil dehydrated with molecular sieves than by distillation. (author)

  14. Analysis of trace elements in scalp hair of healthy people, hyperplasia and breast cancer patients with XRF method

    Science.gov (United States)

    Kolmogorov, Yuriy; Kovaleva, Valentina; Gonchar, Alexandr

    2000-06-01

    The possibilities of using the energy dispersion X-ray fluorescence analysis (XRF) and synchrotron radiation X-ray fluorescence analysis (SRXFA) for the control of trace elements (TE) content in the hair of women with mammary hyperplasia and cancer are demonstrated. Ten hair samples were taken from 25- to 60-year-old women who have been operated for mammary cancer and from 23 patients under oncologist's observation on the occasion of hyperplastic process in the mammary gland (fibrocystous mastopathy). The results of the analyses of trace elements content in the hair of 52 practically healthy women were used as control. The results demonstrated that scalp hair of patients with oncological mammary pathology are characterized by the significant decrease of the concentration of selenium (Se) and zinc (Zn), and by the increase of chromium (Cr). The Se deficit was more pronounced in patients with cancer than in those with hyperplasia (fiducial probability p<0.05)

  15. Analysis of trace elements in airborne particulate matters collected in Ankara, Turkey by TXRF

    Directory of Open Access Journals (Sweden)

    Durukan I.

    2013-04-01

    Full Text Available The main focus point of the presented study was the assessment of atmospheric burden of particulate matter and toxic trace metals in the atmosphere of Ankara, Turkey. For this purpose, outdoor samplings were accomplished in the capital city, Ankara. The types of filters, sample collection and sample preparation methods were investigated and optimized. Analyses were provided by the total reflection X-ray fluorescence (TXRF spectroscopic technique in Germany. Spatial and temporal variations of air particulate matter (APM levels in the city were examined. In some stations, APM sampled in according to their size distribution such as PM10 and PM2.5. Elemental characterization of size distributed PM were achieved and evaluated. It was detected that the elements mainly originated from soil in Beytepe station, from soil and solid fuel usage in Kayas station and from traffic and a variety of human activities in Sıhhiye station in air samplings. While the elements of natural origin observed in PM10 fraction, the elements from traffic and human activities were in PM2.5. Eventually, enrichment calculations were performed in order to identify the pollution sources.

  16. Trace elemental analysis of Indian natural moonstone gems by PIXE and XRD techniques.

    Science.gov (United States)

    Venkateswara Rao, R; Venkateswarulu, P; Kasipathi, C; Sivajyothi, S

    2013-12-01

    A selected number of Indian Eastern Ghats natural moonstone gems were studied with a powerful nuclear analytical and non-destructive Proton Induced X-ray Emission (PIXE) technique. Thirteen elements, including V, Co, Ni, Zn, Ga, Ba and Pb, were identified in these moonstones and may be useful in interpreting the various geochemical conditions and the probable cause of their inceptions in the moonstone gemstone matrix. Furthermore, preliminary XRD studies of different moonstone patterns were performed. The PIXE technique is a powerful method for quickly determining the elemental concentration of a substance. A 3MeV proton beam was employed to excite the samples. The chemical constituents of moonstones from parts of the Eastern Ghats geological formations of Andhra Pradesh, India were determined, and gemological studies were performed on those gems. The crystal structure and the lattice parameters of the moonstones were estimated using X-Ray Diffraction studies, trace and minor elements were determined using the PIXE technique, and major compositional elements were confirmed by XRD. In the present work, the usefulness and versatility of the PIXE technique for research in geo-scientific methodology is established. © 2013 Elsevier Ltd. All rights reserved.

  17. Natural wetland emissions of methylated trace elements

    NARCIS (Netherlands)

    Vriens, B.; Lenz, M.; Charlet, L.; Berg, M.; Winkel, L.H.E.

    2014-01-01

    Natural wetlands are well known for their significant methane emissions. However, trace element emissions via biomethylation and subsequent volatilization from pristine wetlands are virtually unstudied, even though wetlands constitute large reservoirs for trace elements. Here we show that the

  18. Sampling and sample preparation methods for the analysis of trace elements in biological material

    International Nuclear Information System (INIS)

    Sansoni, B.; Iyengar, V.

    1978-05-01

    The authors attempt to give a most systamtic possible treatment of the sample taking and sample preparation of biological material (particularly in human medicine) for trace analysis (e.g. neutron activation analysis, atomic absorption spectrometry). Contamination and loss problems are discussed as well as the manifold problems of the different consistency of solid and liquid biological materials, as well as the stabilization of the sample material. The process of dry and wet ashing is particularly dealt with, where new methods are also described. (RB) [de

  19. Total reflection X-ray fluorescence analysis of trace-elements in candies marketed in Mexico

    Science.gov (United States)

    Martinez, T.; Lartigue, J.; Zarazua, G.; Avila-Perez, P.; Navarrete, M.; Tejeda, S.

    2010-06-01

    Trace metals concentrations in food are significant for nutrition, due either to their nature or toxicity. Sweets, including chewing gum and candies, are not exactly a food, but they usually are unwearied consumed by children, the most vulnerable age-group to any kind of metal contamination in the food chain. The presence of relatively high concentrations of heavy metals such as Lead elicits concern since children are highly susceptible to heavy metals poisoning. Trace-metals concentrations were determined for six different flavors of a Mexican candy by means of Total X-ray Fluorescence Spectrometry. Triplicate samples of the various candy's flavours (strawberry, pineapple, lemon, blackberry, orange and chilli) were digested in 8 mL of a mix of supra-pure HNO 3 and H 2O 2 (6 mL: 2 mL) in a microwave oven MARS-X. Results show the presence of essential and toxic elements such as Ti, Cr, Mn, Fe, Ni, Cu, Zn, Br, Rb, Sr, and Pb. All metal concentrations were higher and significantly different ( α = 0.05) in chilli candy, compared to other candy flavours. Lead concentration fluctuated in the range of 0.102 to 0.342 μg g - 1 . A discussion about risk consumption and concentration allowed by Mexican and International Norms is made. As a part of the Quality Control Program, a NIST standard of "Citrus Leaves" and a blank were treated in the same way.

  20. Total reflection X-ray fluorescence analysis of trace-elements in candies marketed in Mexico

    International Nuclear Information System (INIS)

    Martinez, T.; Lartigue, J.; Zarazua, G.; Avila-Perez, P.; Navarrete, M.; Tejeda, S.

    2010-01-01

    Trace metals concentrations in food are significant for nutrition, due either to their nature or toxicity. Sweets, including chewing gum and candies, are not exactly a food, but they usually are unwearied consumed by children, the most vulnerable age-group to any kind of metal contamination in the food chain. The presence of relatively high concentrations of heavy metals such as Lead elicits concern since children are highly susceptible to heavy metals poisoning. Trace-metals concentrations were determined for six different flavors of a Mexican candy by means of Total X-ray Fluorescence Spectrometry. Triplicate samples of the various candy's flavours (strawberry, pineapple, lemon, blackberry, orange and chilli) were digested in 8 mL of a mix of supra-pure HNO 3 and H 2 O 2 (6 mL: 2 mL) in a microwave oven MARS-X. Results show the presence of essential and toxic elements such as Ti, Cr, Mn, Fe, Ni, Cu, Zn, Br, Rb, Sr, and Pb. All metal concentrations were higher and significantly different (α = 0.05) in chilli candy, compared to other candy flavours. Lead concentration fluctuated in the range of 0.102 to 0.342 μg g -1 . A discussion about risk consumption and concentration allowed by Mexican and International Norms is made. As a part of the Quality Control Program, a NIST standard of 'Citrus Leaves' and a blank were treated in the same way.

  1. Food for Thought: A Critical Overview of Current Practical and Conceptual Challenges in Trace Element Analysis in Natural Waters

    Directory of Open Access Journals (Sweden)

    Montserrat Filella

    2013-07-01

    Full Text Available The practical and conceptual challenges faced by the analysis of trace elements present in natural waters are not merely, as is often thought, an endless race towards lower detection limits or to the development of techniques allowing the determination of any possible chemical species formed by all chemical elements. Rather, as discussed in this paper, they include the development of (i robust, cheap, and reliable methods that could also be used by laypeople (the experience gained in the development of field kits for As is discussed as an example from which similar developments for other elements may be drawn; (ii more environmentally-friendly methods (the current guiding criteria probably being too simplistic; and (iii methods making it possible to follow diel concentration changes and sharp concentration variations caused by the probable increase of heavy rainfall events. This paper also claims that neither the measurement of total concentrations (reliable methods are lacking for many elements of the periodic table of trace elements, as illustrated through the cases of Bi, Te, and Sb, nor chemical speciation analysis, are as mature as often thought. In particular, chemical speciation studies demand the development of a better, comprehensive conceptual framework. A trial is carried out to lay the basis of such a framework.

  2. Study of selected trace elements in cancerous and non-cancerous human breast tissues using neutron activation analysis

    International Nuclear Information System (INIS)

    Ebrahim, A. M.

    2006-03-01

    This study was performed to investigate the influence of cancer on selected trace elements among sudanese patients with confirmed breast cancer. Eighty samples of cancerous and normal tissues (total of one hundred and sixty) were obtained from the same breast of the same subject from different hospitals in Khartoum State. Samples were freeze dried and analyzed using neutron activation analysis (NAA). Neutron irradiations were performed at Egypt second research reactor with a maximum thermal flux of 2.37 Χ 10 14 n cm -2 s -1 . To examine if there was any difference in the concentrations of elements from normal and malignant tissues; Wilcox on signed ranks test was used. It was found that Al, Mn, Mg, Se, Zn, and Cr elements from the malignant tissues are significantly elevated (p 0.05). The results obtained have shown consistency with results obtained by some previous studies, however, no data could be found for the elements Mg, Cr, and Sc.(Author)

  3. The trace element analysis in freshwater fish species, water and sediment in Iyidere stream (Rize-Turkey).

    Science.gov (United States)

    Verep, Bulent; Mutlu, Cengiz; Apaydin, Gokhan; Cevik, Ugur

    2012-07-15

    Many environmental problems like dam construction, agricultural debris, flooding and industrial establishments threaten Iyidere stream (Rize, Turkey) on the southeastern coast of the Black Sea (Turkey). The trace element concentrations in water, fish and sediments in lyidere stream (Rize, Turkey) were investigated in this study. The concentration of six different elements in ten freshwater fish species and sediment was determined using energy dispersive X-ray fluorescence method. A radioisotope excited X-ray fluorescence analysis using the method of multiple standard addition is applied for the elemental analysis of fish and sediments. Water samples for trace metals were analyzed using standard spectrophotometry methods. A qualitative analysis of spectral peaks showed that ten different freshwater fish samples (Chondrostoma colchicum, Chalcalburnus chalcoides, Salmo trutta labrax, Alburnoides bipunctatus, Leuciscus cephalus, Barbus taurus escherichia, Capoeta tinca, Neogobius kessleri, Rutilus frisii, Lampetra lanceolata) and sediment contained phosphorus (P), sulphur (S), chlorine (Cl), potassium (K), calcium (Ca) and titanium (Ti). Heavy metals as toxic elements for biota (Pb, Cd, Hg, Zn and Mn etc.) were not detected in fish, water and sediments. Thus, It can be declared that freshwater fish of Iyidere does not contains health risks for consumers in terms of metal pollution.

  4. Direct Trace Element Analysis of Liquid Blood Samples by In-Air Ion Beam Analytical Techniques (PIXE-PIGE).

    Science.gov (United States)

    Huszank, Robert; Csedreki, László; Török, Zsófia

    2017-02-07

    There are various liquid materials whose elemental composition is of interest in various fields of science and technology. In many cases, sample preparation or the extraction can be complicated, or it would destroy the original environment before the analysis (for example, in the case of biological samples). However, multielement direct analysis of liquid samples can be realized by an external PIXE-PIGE measurement system. Particle-induced X-ray and gamma-ray emission spectroscopy (PIXE, PIGE) techniques were applied in external (in-air) microbeam configuration for the trace and main element determination of liquid samples. The direct analysis of standard solutions of several metal salts and human blood samples (whole blood, blood serum, blood plasma, and formed elements) was realized. From the blood samples, Na, P, S, Cl, K, Ca, Fe, Cu, Zn, and Br elemental concentrations were determined. The focused and scanned ion beam creates an opportunity to analyze very small volume samples (∼10 μL). As the sample matrix consists of light elements, the analysis is possible at ppm level. Using this external beam setup, it was found that it is possible to determine elemental composition of small-volume liquid samples routinely, while the liquid samples do not require any preparation processes, and thus, they can be analyzed directly. In the case of lower concentrations, the method is also suitable for the analysis (down to even ∼1 ppm level) but with less accuracy and longer measurement times.

  5. Determination of trace elements in lichen samples by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Saiki, Mitiko; Horimoto, Lidia K.; Vasconcellos, Marina B.A.; Marcelli, Marcelo P.; Sumita, Nairo M.; Saldiva, Paulo H.N.

    2001-01-01

    Samples of Canoparmelia texana lichen collected in different sites of Sao Paulo and Parana States, Brazil, were analysed by neutron activation analysis in order to obtain preliminary information on the air quality in these regions and also to select a region of interest for biomonitoring studies. Also Tadescantia pallida plant has been analysed in order to study the viability of using this specimen in environmental pollution monitoring. Lichens samples were collected from tree barks which were also collected to investigate the contribution of substrate derived elements to elements present in lichens. Young and old leaves of T. pallida were collected separately in order to study the leaf age effects on their elemental levels. The samples were cleaned, washed with distilled water, dried and ground for the analyses. Samples and standards were irradiated at the IEA-Rlm nuclear reactor for short and long periods and concentrations of the elements Al, As, Ca, Cd, Cl, Co, Cr, Cs, Fe, Hf, Mg, Mn, Rb, Sb, Sc, D, Th, U, V Zn and lanthanides were determined. Preliminary results obtained for T. texana lichen indicated that three sites (Ibiuna, Botanical Garden and Parque de Vila Velha) present low concentrations of the most elements analysed. Therefore lichens from these regions could be analysed to establish baseline levels of elements for monitoring purposes. Samples collected in open areas presented high concentrations of some elements probably due to the accumulation of elements originating from soil and from heavy vehicular traffic. Elemental concentrations obtained in outer barks were similar or smaller than those results obtained for lichens. Results obtained for T. pallida indicated that concentrations of elements in old leaves of this plant are of the same magnitude or slightly higher than those presented in young ones. (author)

  6. Microwave-assisted diluted acid digestion for trace elements analysis of edible soybean products.

    Science.gov (United States)

    Barbosa, José Tiago P; Santos, Clarissa M M; Peralva, Vanessa N; Flores, Erico M M; Korn, Mauro; Nóbrega, Joaquim A; Korn, Maria Graças A

    2015-05-15

    A new method for the decomposition of soybean based edible products (soy extract, textured soy protein, transgenic soybeans, and whole soy flour) was developed to essential (Co, Cr, Cu, Fe, Mn, Ni, Se, V, and Zn) and non-essential (As, Ba, Cd, Pb, and Sr) trace elements determination by ICP OES and ICP-MS respectively. Effects related to the concentration of HNO3 (2.1-14.5 mol L(-1)) and the use of hydrogen peroxide on the efficiency of decomposition was evaluated based on the residual carbon content (RCC). It was demonstrated that 2.1 mol L(-1) HNO3 plus 1.0 mL H2O2 was suitable for an efficient digestion, since RCC was lower than 18% and the agreement with certified values and spike recoveries were higher than 90% for all analytes. The concentrations of analytes in the samples (minimum-maximum in mgkg(-1)) were: The concentrations of analytes in the samples (minimum-maximum in mgkg(-1)) were: As (foods investigated in this study presented variable composition in terms of essential and potentially toxic elements, which can be attributed to different methods of processing. Copyright © 2014 Elsevier Ltd. All rights reserved.

  7. Atmospheric pollution in an urban environment by tree bark biomonitoring--part I: trace element analysis.

    Science.gov (United States)

    Guéguen, Florence; Stille, Peter; Lahd Geagea, Majdi; Boutin, René

    2012-03-01

    Tree bark has been shown to be a useful biomonitor of past air quality because it accumulates atmospheric particulate matter (PM) in its outermost structure. Trace element concentrations of tree bark of more than 73 trees allow to elucidate the impact of past atmospheric pollution on the urban environment of the cities of Strasbourg and Kehl in the Rhine Valley. Compared to the upper continental crust (UCC) tree barks are strongly enriched in Mn, Ni, Cu, Zn, Cd and Pb. To assess the degree of pollution of the different sites in the cities, a geoaccumulation index I(geo) was applied. Global pollution by V, Ni, Cr, Sb, Sn and Pb was observed in barks sampled close to traffic axes. Cr, Mo, Cd pollution principally occurred in the industrial area. A total geoaccumulation index I(GEO-tot) was defined; it is based on the total of the investigated elements and allows to evaluate the global pollution of the studied environment by assembling the I(geo) indices on a pollution map. Copyright © 2011 Elsevier Ltd. All rights reserved.

  8. Utilization of Neutron Activation Analysis for geochemical study of major and trace elements in Bouregreg river basin (Morocco)

    International Nuclear Information System (INIS)

    Bounouira, H.; Bounakhla, M.; Embarch, K.; Choukri, A.; Cherkaoui, R.; Gaudry, A.; Treuil, M.; Chakiri, S.

    2010-01-01

    The Bouregreg river basin is located in the moroccan central massif which consists mainly of palaeozoic formations that were subject to the Hercynian orogeny. This study documents the backround geochemistry and hydrochemistry of the Bouregreg river basin, focusing on the distribution of major and trace elements, Rock samples were collected at 9 locations along the bouregreg river and its tributaries in the winter of 2005. Major (Al, fe, Mn, Na, K and Ti) and trace (Rb, Cs, Sr, Sc, Ba, Cr, V, Co, Ni, Zn, As, Sb, La, Ce, Nd, Sm, Tb, Dy, Yb, Lu, Hf, Ta, Mo, Th and U) elements were anlysed using instrumental Neutron Activation Analysis (INAA). Data show that most of the geochemistry and hydrochemistry are related to regional and local geology. the geochemical heritage of geological environment in the Bouregreg river basin is very important, that results from the more compatible behaviour and the inertia of some elements during the weathering (3d transition elements (Co, Ni, Cr,...), interne transition elements f (lanthanides, Zr, Hf, Nb, Ta,...)). The geochemical homogeneity of the basin shows also heritage during the crustal accretion (magmatism-metamorphism-sedimention) and the typology of this continental area is the same that the Upper Continental Crust (UCC). Some anomalously high heavy metal analyses, particulary for As and Sb, may be related to anthropogenic activities

  9. Determination of trace elements in eyeshadow, face powder and rouge make-up cosmetics by neutron activation analysis

    International Nuclear Information System (INIS)

    Kanias, G.D.

    1985-01-01

    Some trace elements exist in cosmetics due to the mineral origin of their raw materials and there is no information about their concentration levels in these products. Instrumental neutron activation analysis was applied to determine the elements: cerium, cesium, europium, hafnium, lanthanum, lutetium, potassium, rubidium, samarium, scandium, sodium, tantalum, terbium, tungsten and ytterbium in eyeshadow, face powder and rouge make-up cosmetic products from the Greek market. According to the results, a wide range of values was found between the three examined cosmetics as well as between the different samples belonging to the same kind of cosmetics. This probably could be attributed to the various manufacturers of the analyzed samples. Moreover, the use of neutron activation analysis as a suitable routine method is discussed for the control of some elements which must not be contained in cosmetics. (author)

  10. Identification of Se trace element in the soybean using neutron activation analysis

    International Nuclear Information System (INIS)

    Sihombing, E.; Sri Wardani; Hamzah, A.

    1999-01-01

    Neutron Activation Analysis method has been developed as a fast analysis method with high sensitivity, accuracy and precision in determining distribution of element content of various types of seed food materials. In this research the element content of Se was determined by irradiating sample of black and white soybean that can be bought in the market. For determining the content of long decay time element of Se, a samples of 1.3 - 2.3 grams of seed was irradiated within 45 minutes where as for short decay time of Se, the 1,2 - 2,2 grams of seed was irradiated within 30 minutes in the reactor wall. The activated sample, then, was analyzed using gamma spectrometry method. The gamma spectrum was acquired with Hp Ge detector with counting time within 2 - 60 minutes. The results showed that there is a small deviation on Se's quantity of contents with vary between 154,2 and 165,8 ppb

  11. Atom trap trace analysis

    Energy Technology Data Exchange (ETDEWEB)

    Lu, Z.-T.; Bailey, K.; Chen, C.-Y.; Du, X.; Li, Y.-M.; O' Connor, T. P.; Young, L.

    2000-05-25

    A new method of ultrasensitive trace-isotope analysis has been developed based upon the technique of laser manipulation of neutral atoms. It has been used to count individual {sup 85}Kr and {sup 81}Kr atoms present in a natural krypton sample with isotopic abundances in the range of 10{sup {minus}11} and 10{sup {minus}13}, respectively. The atom counts are free of contamination from other isotopes, elements,or molecules. The method is applicable to other trace-isotopes that can be efficiently captured with a magneto-optical trap, and has a broad range of potential applications.

  12. Trace element and stable isotope analysis of fourteen species of marine invertebrates from the Bay of Fundy, Canada.

    Science.gov (United States)

    English, Matthew D; Robertson, Gregory J; Mallory, Mark L

    2015-12-15

    The Bay of Fundy, Canada, is a macrotidal bay with a highly productive intertidal zone, hosting a large abundance and diversity of marine invertebrates. We analysed trace element concentrations and stable isotopic values of δ(15)N and δ(13)C in 14 species of benthic marine invertebrates from the Bay of Fundy's intertidal zone to investigate bioaccumulation or biodilution of trace elements in the lower level of this marine food web. Barnacles (Balanus balanus) consistently had significantly greater concentrations of trace elements compared to the other species studied, but otherwise we found low concentrations of non-essential trace elements. In the range of trophic levels that we studied, we found limited evidence of bioaccumulation or biodilution of trace elements across species, likely due to the species examined occupying similar trophic levels in different food chains. Copyright © 2015 Elsevier Ltd. All rights reserved.

  13. Total reflection X-ray fluorescence analysis of trace-elements in candies marketed in Mexico

    Energy Technology Data Exchange (ETDEWEB)

    Martinez, T., E-mail: tmc@servidor.unam.m [Facultad de Quimica, Departamento de Quimica Inorganica y Nuclear. Universidad Nacional Autonoma de Mexico, Mexico D.F. 04510 (Mexico); Lartigue, J. [Facultad de Quimica, Departamento de Quimica Inorganica y Nuclear. Universidad Nacional Autonoma de Mexico, Mexico, D.F. 04510 (Mexico); Zarazua, G.; Avila-Perez, P. [National Institute of Nuclear Research. Ocoyoacac, Edo. de Mexico, 05045 (Mexico); Navarrete, M. [Facultad de Quimica, Departamento de Quimica Inorganica y Nuclear. Universidad Nacional Autonoma de Mexico, Mexico, D.F. 04510 (Mexico); Tejeda, S. [National Institute of Nuclear Research. Ocoyoacac, Edo. de Mexico, 05045 (Mexico)

    2010-06-15

    Trace metals concentrations in food are significant for nutrition, due either to their nature or toxicity. Sweets, including chewing gum and candies, are not exactly a food, but they usually are unwearied consumed by children, the most vulnerable age-group to any kind of metal contamination in the food chain. The presence of relatively high concentrations of heavy metals such as Lead elicits concern since children are highly susceptible to heavy metals poisoning. Trace-metals concentrations were determined for six different flavors of a Mexican candy by means of Total X-ray Fluorescence Spectrometry. Triplicate samples of the various candy's flavours (strawberry, pineapple, lemon, blackberry, orange and chilli) were digested in 8 mL of a mix of supra-pure HNO{sub 3} and H{sub 2}O{sub 2} (6 mL: 2 mL) in a microwave oven MARS-X. Results show the presence of essential and toxic elements such as Ti, Cr, Mn, Fe, Ni, Cu, Zn, Br, Rb, Sr, and Pb. All metal concentrations were higher and significantly different ({alpha} = 0.05) in chilli candy, compared to other candy flavours. Lead concentration fluctuated in the range of 0.102 to 0.342 {mu}g g{sup -1}. A discussion about risk consumption and concentration allowed by Mexican and International Norms is made. As a part of the Quality Control Program, a NIST standard of 'Citrus Leaves' and a blank were treated in the same way.

  14. A comparison of sample preparation strategies for biological tissues and subsequent trace element analysis using LA-ICP-MS.

    Science.gov (United States)

    Bonta, Maximilian; Török, Szilvia; Hegedus, Balazs; Döme, Balazs; Limbeck, Andreas

    2017-03-01

    Laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS) is one of the most commonly applied methods for lateral trace element distribution analysis in medical studies. Many improvements of the technique regarding quantification and achievable lateral resolution have been achieved in the last years. Nevertheless, sample preparation is also of major importance and the optimal sample preparation strategy still has not been defined. While conventional histology knows a number of sample pre-treatment strategies, little is known about the effect of these approaches on the lateral distributions of elements and/or their quantities in tissues. The technique of formalin fixation and paraffin embedding (FFPE) has emerged as the gold standard in tissue preparation. However, the potential use for elemental distribution studies is questionable due to a large number of sample preparation steps. In this work, LA-ICP-MS was used to examine the applicability of the FFPE sample preparation approach for elemental distribution studies. Qualitative elemental distributions as well as quantitative concentrations in cryo-cut tissues as well as FFPE samples were compared. Results showed that some metals (especially Na and K) are severely affected by the FFPE process, whereas others (e.g., Mn, Ni) are less influenced. Based on these results, a general recommendation can be given: FFPE samples are completely unsuitable for the analysis of alkaline metals. When analyzing transition metals, FFPE samples can give comparable results to snap-frozen tissues. Graphical abstract Sample preparation strategies for biological tissues are compared with regard to the elemental distributions and average trace element concentrations.

  15. Neutron activation analysis and the geochemistry of common and trace elements at extinction boundaries in the geological record

    International Nuclear Information System (INIS)

    Attrep, M. Jr.; Orth, C.J.; Quintana, L.R.

    1994-01-01

    The discovery of the iridium anomaly at the 65-Ma Cretaceous-Tertiary (K-T) extinction boundary initiated numerous investigations, including the search for the coupling of these extinctions with other astronomical events. One hypothesis is that these periodic extinctions are coupled to terrestrial impacts from cyclic swarms of comets or asteroids. The studies have focused on elucidating the conditions and causes of extinction of life at these geological boundaries using elemental abundance patterns. The authors use instrumental neutron activation methods to determine whole-rock abundances for about 40 trace and common elements in thousands of samples. The platinum group elements (iridium, gold, platinum, and osmium) and nickel are measured by radiochemical activation analysis. The authors can measure iridium at levels down to 1 picogram/gram level

  16. Trace elemental analysis in cancer-afflicted tissues of penis and testis by PIXE technique

    International Nuclear Information System (INIS)

    Naga Raju, G.J.; John Charles, M.; Bhuloka Reddy, S.; Sarita, P.; Seetharami Reddy, B.; Rama Lakshmi, P.V.B.; Vijayan, V.

    2005-01-01

    PIXE technique was employed to estimate the trace elemental concentrations in the biological samples of cancerous penis and testis. A 3 MeV proton beam was employed to excite the samples. From the present results it can be seen that the concentrations of Cl, Fe and Co are lower in the cancerous tissue of the penis when compared with those in normal tissue while the concentrations of Cu, Zn and As are relatively higher. The concentrations of K, Ca, Ti, Cr, Mn, Br, Sr and Pb are in agreement within standard deviations in both cancerous and normal tissues. In the cancerous tissue of testis, the concentrations of K, Cr and Cu are higher while the concentrations of Fe, Co and Zn are lower when compared to those in normal tissue of testis. The concentrations of Cl, Ca, Ti and Mn are in agreement in both cancerous and normal tissues of testis. The higher levels of Cu lead to the development of tumor. Our results also support the underlying hypothesis of an anticopper, antiangiogenic approach to cancer therapy. The Cu/Zn ratios of both penis and testis were higher in cancer tissues compared to that of normal

  17. Trace elemental analysis in cancer-afflicted tissues of penis and testis by PIXE technique

    Energy Technology Data Exchange (ETDEWEB)

    Naga Raju, G.J. [Swami Jnanananda Laboratories for Nuclear Research, Andhra University, Visakhapatnam 530 003 (India); John Charles, M. [Swami Jnanananda Laboratories for Nuclear Research, Andhra University, Visakhapatnam 530 003 (India); Bhuloka Reddy, S. [Swami Jnanananda Laboratories for Nuclear Research, Andhra University, Visakhapatnam 530 003 (India)]. E-mail: sbr_r@yahoo.com; Sarita, P. [Swami Jnanananda Laboratories for Nuclear Research, Andhra University, Visakhapatnam 530 003 (India); Seetharami Reddy, B. [Swami Jnanananda Laboratories for Nuclear Research, Andhra University, Visakhapatnam 530 003 (India); Rama Lakshmi, P.V.B. [Pathology Department, Andhra Medical College, Visakhapatnam 530 002 (India); Vijayan, V. [Institute of Physics, Sachivalaya Marg, Bhubaneswar 751 001 (India)

    2005-04-01

    PIXE technique was employed to estimate the trace elemental concentrations in the biological samples of cancerous penis and testis. A 3 MeV proton beam was employed to excite the samples. From the present results it can be seen that the concentrations of Cl, Fe and Co are lower in the cancerous tissue of the penis when compared with those in normal tissue while the concentrations of Cu, Zn and As are relatively higher. The concentrations of K, Ca, Ti, Cr, Mn, Br, Sr and Pb are in agreement within standard deviations in both cancerous and normal tissues. In the cancerous tissue of testis, the concentrations of K, Cr and Cu are higher while the concentrations of Fe, Co and Zn are lower when compared to those in normal tissue of testis. The concentrations of Cl, Ca, Ti and Mn are in agreement in both cancerous and normal tissues of testis. The higher levels of Cu lead to the development of tumor. Our results also support the underlying hypothesis of an anticopper, antiangiogenic approach to cancer therapy. The Cu/Zn ratios of both penis and testis were higher in cancer tissues compared to that of normal.

  18. Neutron activation analysis of trace elements in human hair by using a research reactor

    International Nuclear Information System (INIS)

    Takeuchi, Takayuki

    1997-01-01

    Recently, hair has been used for diagnosis of various diseases as well as blood and urine since hair is one of excretory tissues for various elements in humans. Many elements are excreted in hairs at higher concentrations than those in blood and urine. Therefore, it seems possible to estimate the effects of radiation exposure in the past. Here, the levels of elements in hairs were determined by radiation analysis using nuclear reactor. When mercury level was compared among the hairs from various countries of the world, the levels of Japanese and English were 4 ppm or more, significantly higher than around 2 ppm for the subjects in other countries. The levels were higher in cities than in the suburbs in any country, indicating that the differences might be due to air pollution. Furthermore, it was found that radioactive levels of some elements in hair were dependent on sex, especially for Ca, Cu etc. and on preexposure to a perm for Br, Ca, Mg etc. In addition, neutron analysis was indicated to be available for diagnosis of some diseases; the aluminum concentration in hairs was significantly lower in the patients with Alzheimer's disease than those with cerebrovascular diseases and the control subjects. The levels of As, Co, Cd and Hg in hairs were demonstrated to be several hundred fold higher in a woman named Otaki who died in nearly 1829 than those levels of the modern Japanese women, showing that various toxic materials such as cosmetics were used in those days. (M.N.)

  19. Major to ultra trace element bulk rock analysis of nanoparticulate pressed powder pellets by LA-ICP-MS

    Science.gov (United States)

    Peters, Daniel; Pettke, Thomas

    2016-04-01

    An efficient, clean procedure for bulk rock major to trace element analysis by 193 nm Excimer LA-ICP-MS analysis of nanoparticulate pressed powder pellets (PPPs) employing a binder is presented. Sample powders are milled in water suspension in a planetary ball mill, reducing average grain size by about one order of magnitude compared to common dry milling protocols. Microcrystalline cellulose (MCC) is employed as a binder, improving the mechanical strength of the PPP and the ablation behaviour, because MCC absorbs 193 nm laser light well. Use of MCC binder allows for producing cohesive pellets of materials that cannot be pelletized in their pure forms, such as quartz powder. Rigorous blank quantification was performed on synthetic quartz treated like rock samples, demonstrating that procedural blanks are irrelevant except for a few elements at the 10 ng g-1 concentration level. The LA-ICP-MS PPP analytical procedure was optimised and evaluated using six different SRM powders (JP-1, UB-N, BCR-2, GSP-2, OKUM, and MUH-1). Calibration based on external standardization using SRM 610, SRM 612, BCR-2G, and GSD-1G glasses allows for evaluation of possible matrix effects during LA-ICP-MS analysis. The data accuracy of the PPP LA-ICP-MS analytical procedure compares well to that achieved for liquid ICP-MS and LA-ICP-MS glass analysis, except for element concentrations below ˜30 ng g-1, where liquid ICP-MS offers more precise data and in part lower limits of detection. Uncertainties on the external reproducibility of LA-ICP-MS PPP element concentrations are of the order of 0.5 to 2 % (1σ standard deviation) for concentrations exceeding ˜1 μg g-1. For lower element concentrations these uncertainties increase to 5-10% or higher when analyte-depending limits of detection (LOD) are approached, and LODs do not significantly differ from glass analysis. Sample homogeneity is demonstrated by the high analytical precision, except for very few elements where grain size effects can

  20. The potential of on-line continuous leach ICP-MS analysis for linking trace elements to mineralogy

    Science.gov (United States)

    Roskam, Gerlinde; Verheul, Marc; Moraetis, Daniel; Giannakis, George; van Gaans, Pauline

    2014-05-01

    A set of five soil samples was subjected to an on-line continuous leach inductively coupled plasma mass spectrometry experiment, with progressively reactive solvents (0.01M CaCl2, 0.1 M HNO3, 1M HNO3, 4M HNO3) Each sample was packed in a quartz tube (Ø= 1 cm, length 2 cm) and diluted 1:1 with acid washed quartz to prevent clogging. The gas that was produced during the extraction was removed by leading the effluent into a small container, from where the sample was directly pumped into the ICP-MS. 115In was used as an internal standard. Continuous leach experiments have the advantage of real time (every 2 seconds) full elemental analysis. Mineral breakdown reactions can be monitored via the major elements. The trace elements associated with the minerals are monitored simultaneously, thus eliminating the uncertainties of host mineral-trace element combinations in traditional off-line sequential extractions. The continuous leach experimental data are correlated to XRD-results for mineralogy and total elemental concentrations. The soil samples used were collected from different sites in the Koiliaris River watershed, Crete, Greece 1). The selection of the sites was based on variability in bedrock (limestone, metamorphic and alluvial sediments) and current land use (grape farming, olive trees). Soils were sampled at two depths: at the surface and just above the bedrock. No large differences in the major elements between the two depths were measured. To provide background to the on-line sequential data, also total concentrations of the major elements were analysed by XRF and the mineralogy was analysed by XRD. The fraction <2mm was sieved and digested with HF, HClO4 and HNO3 for additional trace element analysis. 1) See related abstract Roskam et al., 2014: REE profiles in continuous leach ICP-MS (CL-ICP-MS) experiments in soil, linked to REE profiles in surface water in the Koiliaris River Critical Zone Observatory (CZO), Crete, Greece.

  1. Statistically sound evaluation of trace element depth profiles by ion beam analysis

    International Nuclear Information System (INIS)

    Schmid, K.; Toussaint, U. von

    2012-01-01

    This paper presents the underlying physics and statistical models that are used in the newly developed program NRADC for fully automated deconvolution of trace level impurity depth profiles from ion beam data. The program applies Bayesian statistics to find the most probable depth profile given ion beam data measured at different energies and angles for a single sample. Limiting the analysis to % level amounts of material allows one to linearize the forward calculation of ion beam data which greatly improves the computation speed. This allows for the first time to apply the maximum likelihood approach to both the fitting of the experimental data and the determination of confidence intervals of the depth profiles for real world applications. The different steps during the automated deconvolution will be exemplified by applying the program to artificial and real experimental data.

  2. Additional considerations for trace element analysis of environmental matrices using inductively coupled plasma atomic emission spectrometry with ultrasonic nebulization

    Energy Technology Data Exchange (ETDEWEB)

    Hoenig, M.; Baeten, H. [Cerva, Tervuren (Belgium); Docekalova, H. [Brno Univ. Technical, Faculty of Chemistry (Czech Republic)

    2000-06-01

    This work compares efficiencies of pneumatic and ultrasonic nebulizers and discusses drawbacks observed in trace element analyses of environmental matrices using ICP-AES with ultrasonic nebulization. The interference observed is mainly due to variable calcium content in samples; in most cases the excessive plasma loading by Ca'is responsible for signal suppression of analyte elements. Such matrix effect may be managed to a certain extent using a classical internal standardisation that is discussed in details. Under well defined conditions, the ICP-AES-USN analysis of most trace elements leads to accurate results for matrices usually studied. However, due to chemical reactions occurring in the condensation stage of the ultrasonic nebulizer and subsequent analyte losses to the waste, the ICP-AES-USN analysis of copper and particularly of boron has to be avoided because it leads unavoidably to erroneous results. This drawback cannot be resolved by usual means of correction but may be overcome by using conventional pneumatic nebulizers. (authors)

  3. Zinc: a multipurpose trace element

    Energy Technology Data Exchange (ETDEWEB)

    Stefanidou, M.; Maravelias, C.; Dona, A.; Spiliopoulou, C. [University of Athens, Department of Forensic Medicine and Toxicology, Athens (Greece)

    2006-01-01

    Zinc (Zn) is one of the most important trace elements in the body and it is essential as a catalytic, structural and regulatory ion. It is involved in homeostasis, in immune responses, in oxidative stress, in apoptosis and in ageing. Zinc-binding proteins (metallothioneins, MTs), are protective in situations of stress and in situations of exposure to toxic metals, infections and low Zn nutrition. Metallothioneins play a key role in Zn-related cell homeostasis due to their high affinity for Zn, which is in turn relevant against oxidative stress and immune responses, including natural killer (NK) cell activity and ageing, since NK activity and Zn ion bioavailability decrease in ageing. Physiological supplementation of Zn in ageing and in age-related degenerative diseases corrects immune defects, reduces infection relapse and prevents ageing. Zinc is not stored in the body and excess intakes result in reduced absorption and increased excretion. Nevertheless, there are cases of acute and chronic Zn poisoning. (orig.)

  4. Characterisation and analysis of persistent organic pollutants and major, minor and trace elements in Calabash chalk.

    Science.gov (United States)

    Dean, J R; Deary, M E; Gbefa, B K; Scott, W C

    2004-10-01

    Analysis of Calabash chalk has been done using energy dispersive X-ray fluorescence spectroscopy (EDXRF), X-ray diffraction (XRD) and pressurised fluid extraction (PFE) followed by gas chromatography (GC) with mass selective detection (MSD). It was found by XRD that the composition of Calabash chalk was an aluminium silicate hydroxide from the kaolin clay group with the possible formula Al(2)Si(2)O(5)(OH)(4). Multi-elemental analysis by EDXRF was able to quantify 22 elements in Calabash chalk including lead at a mean concentration of approximately 40 mg/kg. A range of persistent organic pollutants were identified and quantified in Calabash chalk including alpha lindane, endrin, endosulphan II and p,p'-DDD using PFE-GC-MSD.

  5. Trace element characteristics of indian cigarette tobacco by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Garg, A.N.; Vivek Singh; Chutke, N.L.; Ambulkar, M.N.

    1995-01-01

    In order to determine hazardous effects of smoking five different brands of Indian cigarette tobacco including its ash and smoke, three brands of bi di (a typical of Indian subcontinent) and two of chewing tobacco have been analysed for 24 elements (As, Ba, Br, Ca, Ce, Co, Cr, Cs, Cu, Eu, Fe, Hg, K, Hf, La, Na, P, Rb, Sb, Sc, Se, Sr, Th and Zn) by instrumental neutron activation analysis (INAA). A simple and indigenous smoking device has been developed. A mean ash content of 16.5 ± 1.1% was obtained for different brands of cigarettes whereas smoke content was found to be 4.8±0.8%. It is observed that most elements are retained in ash and a few are transferred to smoke. Percent amount of elements retained in ash and transferred to smoke condensate have been calculated. Significant amounts of Sb, Hg, Co, Se and Zn are transferred to smoke but >90% of Ca, Fe, Sr and Cr are retained in ash. a comparison of elemental contents with the cigarette tobacco from other countries shows comparable amounts for most elements except few minor variations attributable to local soil characteristics. Most elemental contents in bi di and chewing tobacco are comparable except Br, Cr, Na, Se and Sr which are higher in chewing tobacco but its Ca content is lower. Standard Reference Materials Bowen's Kale, Kentucky Reference Cigarette and Citrus Leaves (SRM 1572) along with a newly developed tobacco CRM OTL-1 from Poland were also analysed. (author). 31 refs., 1 fig., 4 tabs

  6. Determination of seven trace elements in human milk, powdered cow's milk and infant foods by neutron activation analysis

    International Nuclear Information System (INIS)

    Grimanis, A.P.; Vassilaki-Grimani, M.; Alexiou, D.; Papadatos, C.

    1979-01-01

    The purpose of this study was to apply neutron activation analysis to the determination of seven trace elements (Co, Cr, Cu, Se, Zn, Rb and As) in colostrum, transitional and mature human milk as well as in powdered cow's milk and commercial infant foods, and thus to find out whether non-breast-fed infants received the same or different amounts of these trace elements as breast-fed ones. Ranges and averages for trace elements in mature human milk, expressed as microgrammes per gramme wet weight, varied as follows: Cr 0.018-0.040 and 0.027; Co 0.0013-0.0030 and 0.0020; Cu 0.38-0.50 and 0.46; Se 0.011-0.022 and 0.015; Zn 1.4-1.7 and 1.5; Rb 0.60-0.66 and 0.63; and As 0.0016-0.0060 and 0.0032. The mean concentrations of the essential trace elements Zn, Se, Cu, Cr and Co in colostrum were, respectively, 3.7, 3.2, 2.4, 1.8 and 1.7 times higher than those in mature human milk. No significant differences in Rb and As concentrations were found between colostrum and mature milk. Average values of Zn and Cu in transitional human milk were, respectively, 3.4 and 1.5 times higher than in mature milk. No significant differences for the rest of the elements were found between these two milk samples. The two milk formulas, half-cream and humanized, contained higher mean concentrations of Zn, Rb and As and similar or lower concentrations of Cr, Co and Se than mature human milk. Half-cream is deficient in Cu; mature human milk contains about 9 times more Cu than the half-cream cow's milk. Humanized milk contains a similar mean concentration of Cu as the mature milk. All examined infant foods contained similar or higher concentrations of all elements determined than did the mature human milk

  7. Evaluation of trace elements in human milk from patients of the Chile metropolitan area by neutron activation analysis

    International Nuclear Information System (INIS)

    Luco Mujica, H.

    1983-01-01

    Human milk samples from 23 patients of the Metropolitan Area of Santiago, Chile, were collected and analysed for the determination of their trace element content. Samples were collected from each patient at the third, fifth and thirtieth day post-partum. The samples were analyzed by neutron activation analysis in its instrumental form, for the determination of Cr, Fe, Co, Zn, Se and Rb, and radiochemically for the analysis of Cu and As. It was observed than those elements classified as essential for the normal growth of child, presented concentration levels in agreement with the values recommended by International Health Organizations. Arsenic was not detected in the samples analyzed. It was found not significant difference between the three types of milk analyzed (calostrum, transition and madure), with the exception of Rb and Zn. (Author)

  8. Determination of trace elements in airborne particulate matter. Pt. 2

    International Nuclear Information System (INIS)

    Pamuk, F.; Kahraman, N.; Kut, D.

    1975-04-01

    Several trace elements are being introduced into the atmosphere from various sources. Since many of the trace elements are highly toxic, the concentrations of them should be measured and controlled continuously for public health. Concentrations of trace elements have been determined in air samples collected from seven different districts of Ankara by the use of instrumental neutron activation analysis and atomic absorption spectrophotometer. (Pamuk, F.; Kahraman, N.; Kut, D.)

  9. Trace elements and protein in human milk

    International Nuclear Information System (INIS)

    Abusamra, Y.I.H.

    1995-01-01

    The trace elements Zn, Fe, Cu, Mn, Ni and Pb and some related major elements which are Ca, Cl K and total protein contents of human samples from ninety mothers were examined in this study. Samples were collected from Khartoum, Khartoum North and Omdurman, from the second day of delivery up to the third month where the milk reaches a relatively stable levels. These samples representing different stages of lactation which are colostrum ( 1-3 days ), tranitional ( up to 14 days ) and mature milk. The principle aim of this study is to measure the trace elements and protein contents in relation to stage of lactation and to compare with the literature. Atomic absorption spectroscopy and X-ray fluorescence were used to measure trace elements in the samples. The methods were found to be quite reliable as proved by the analysis of the standard reference material HM-1. Whereas neutron activation analysis was used for measurements of total protein. Colostrum was found to have the highest amounts of trace elements and protein. Fe mean concentration was 273 g/dm 3 at colostrum stage and it decreased to 146 g/dm 3 in mature milk ( 49% ). Zn decreased from 6000 g/dm 3 in colostrum to 1300 g/dm 3 in mature stage ( 78% ). Mn was 12g/dm 3 in colostrum, and it decreased to 2.9 g/dm 3 in mature milk ( 75% ). Cu decreased from 370 g/dm 3 to 117 g/dm 3 ( 68% ). Ni decreased from 24 g/dm 3 to 8.8 g/dm 3 ( 63% ) and Pb from 12 g/dm 3 to 2.6 g/dm 3 ( 76% ). Total protein was 37.3% of the dry milk in colostrum and it was 12.2% in mature milk. (author). 75 refs., 25 tabs., 30 figs

  10. Trace element pharmacognostical study on diuretic drugs by neutron activation analysis

    International Nuclear Information System (INIS)

    Kanias, G.D.; Loukis, A.; Philianos, S.M.

    1979-01-01

    Some pharmacological properties and especially diuretic action of medicinal plants are attributed to their elemental content. The elements chlorine, manganese, potassium and sodium are determined by instrumental neutron activation analysis in the dry samples of the following drugs: stigmata of Zea mays, leaves of Uva ursi, rhizome of Cynodon dactylon, whole plant of Ceterach officinarum as well as in infusions, decoction of the same drugs and in the water used for these preparations. It has been found that manganese and potassium are transferred partially into prepared solutions. Sodium is not transferred into solutions from any of these drugs while only chlorine is transferred partially into infusion of Zea mays. From these results it is concluded that the diuretic action of the examined drugs should not be attributed exclusively to the presence of their potassium and chlorine content but also to other constituents. (author)

  11. Characterization of trace elements in Casearia medicinal plant by neutron activation analysis.

    Science.gov (United States)

    Yamashita, C I; Saiki, M; Vasconcellos, M B A; Sertié, J A A

    2005-01-01

    Leaves of Casearia sylvestris, Casearia decandra and Casearia obliqua plant species, collected at the Atlantic Forest in Brazil, were analyzed by using instrumental neutron activation analysis (INAA). Short and long irradiations using thermal neutron flux of the IEA-R1 nuclear reactor were carried out for these analyses. Concentrations of Ca, K and Mg were found in these samples at the percentage levels, Br, Cl, Fe, Mn, Na, Rb and Zn at the microg g(-1) levels and Co, Cr, Cs, La, and Sc at the microg kg(-1) levels. Comparisons were made among the element concentrations obtained in these three Casearia species and significant differences were found for the elements Cl, Co, Cs, Cr, La, Mn, Na and Sc. The precision and the accuracy of the results were evaluated by analyzing the certified reference materials NIST-1515 Apple Leaves and NIST-1573a Tomato Leaves.

  12. Determination of major, minor and trace elements in urinary stones by neutron activation analysis

    International Nuclear Information System (INIS)

    Lin, S.M.; Tseng, C.L.; Yang, M.H.

    1987-01-01

    In five kinds of human urinary stones 18 elements have been identified by instrumental neutron activation analysis (INAA). From the results it may be concluded that calcium is the most important initiating cation, magnesium is the second most significant one, and Na, Cl, Sr, Zn, Fe, Br and Co may also play an important role in the stone formation. The results indicate also that ions like Ca, Br and Cu are easily incorporated into the nucleus to form a urate stone: Mg and Sr, into the nucleus to form a magnesium ammonium phosphate stone: and Zn, into the nucleus to form a calcium oxalate combined with apatite stone. The differences in elemental composition among the different kinds of stones as well as across the layers of stones are statistically evaluated. (author)

  13. Determination of trace elements in Tillandsia usneoides by neutron activation analysis for environmental biomonitoring

    International Nuclear Information System (INIS)

    Figueiredo, A.M.G.; Saiki, M.; Ticianelli, R.B.; Domingos, M.; Alves, E.S.; Markert, B.

    2001-01-01

    Neutron activation analysis was applied to the determination of the elements Al, As, Ba, Br, Cl, Co, Cr, Fe, K, Mg, Mn, Mo, Na, Rb, Sb, Sc, Ti, Th, V, Zn and the rare earths La, Ce, Nd, Sm, Eu, Tb and Yb in the epiphytic bromeliad Tillandsia usneoides. The samples were collected at an unpolluted area and exposed in different sites of the city of Sao Paulo, Brazil, and in a control site outside Sao Paulo. The results obtained showed an accumulation of Al, As, Cr, Fe, Mo, Sb, Ti, V and Zn elements in Tillandsia usneoides exposed in polluted sites, indicating a promising potential of this species as a biomonitor of air pollution in Sao Paulo. (author)

  14. Determination of trace elements in lichen samples by neutron activation analysis

    International Nuclear Information System (INIS)

    Saiki, Mitiko; Coccaro, D.M.B.; Vasconcellos, M.B.A.; Marcelli, M.P.

    1999-01-01

    Epiphytic lichens have been used as bioindicators of environmental pollution studies because of their ability to accumulate metals present in the atmosphere at very low concentrations. In this work, experimental conditions for collection and preparation of the lichen samples as well as the experimental procedure for neutron activation analysis were established in order to obtain reliable and useful data for environmental monitoring purposes. Lichen samples were collected from the barks of trees. They were first examined in a stereo microscope, cleaned and then they were washed with water, freeze-dried and ground for analysis. Out of the five species Usnea sp, Parmotrena tinctorum, Canoparmelia caroliniana, Parmotrema sanctiangeli and Canoparmelia texana analysed, the latter was chosen for this work since this species is very abundant on the Brazilian territory except for the coast. The samples and synthetic standards of elements were irradiated at the IEA-R1 nuclear reactor and the concentrations of the elements Al, As, Br, Ca, Cd, Cl, Co, Cr, Cs, Fe, K, lanthanides, Mg, Mn, Na, Rb, Sb, Sc, Se, Th, U, V and Zn were determined by using short and long irradiations. Results obtained in the washed and unwashed lichen samples showed that the cleaning with water can be used in order to eliminate adhering materials. Indeed, most of elements of interest for the environmental contamination accumulated by the lichens were not removed. The study of the influence of the age of the lichen indicated that its elemental concentrations increase with its age or with the length of exposure. Results obtained for lichens collected from four different trees in the same sampling area varied from about 3.4 to 50%. The homogeneity of the sample was checked by analyzing replicates. The precision and the accuracy of the method were evaluated by analyzing IAEA 336 Lichen and NIST 1752 Citrus Leaves. (author)

  15. Trace element content of precipitation in a remote area

    International Nuclear Information System (INIS)

    Merritt, W.F.

    1976-01-01

    Rain and snow, sampled over a period of 18 months at Chalk River Nuclear Laboratories, were analysed for 40 elements by thermal neutron activation analysis. Correlation analysis revealed that the elements detected could be divided into groups of similar behaviour. Storm tracks for the events sampled were obtained, but only generalizations as to the probable origin of the trace elements could be made. Deuterium content of the samples was not correlated with levels of trace elements. (author)

  16. Trace elements in sera from patients with visceral leishmaniasis

    International Nuclear Information System (INIS)

    Mukhopadhyay, R.; Bhattacharya, A.; Chakraborty, A.; Sudarshan, M.; Jal, P.K.; Chintalapudi, S.N.; Dutta, R.K.

    2000-01-01

    Trace elements are known to have pivotal role in human health and disease. Present investigation employed PIXE analysis to probe into the elemental profile of patients suffering from visceral Leishmaniasis. Remarkable alternations were observed in concentration of elements like Cl, K, Ca, Mn, Fe, Cu, Zn. The pattern of enhancement of elemental concentration corresponds to the progression of the disease. Additionally, our present data reflect probable correlation between alteration in trace elemental status and other pathological syndromes associated with Leishmaniasis. The possibility of considering trace elements as a diagnostic marker for a better understanding of the disease is discussed. (author)

  17. Trace elements in sera from patients with visceral leishmaniasis

    Energy Technology Data Exchange (ETDEWEB)

    Mukhopadhyay, R.; Bhattacharya, A. [Department of Zoology, Calcutta University, Calcutta (India); Chakraborty, A.; Sudarshan, M.; Jal, P.K.; Chintalapudi, S.N. [Inter University Consortium for DAE Facilities, Calcutta Centre 3/LB-8, Bidhan Nagar, Calcutta (India); Dutta, R.K. [Schonland Research Centre for Nuclear Sciences, University of Witwatersrand, Johannesburg (South Africa)

    2000-07-01

    Trace elements are known to have pivotal role in human health and disease. Present investigation employed PIXE analysis to probe into the elemental profile of patients suffering from visceral Leishmaniasis. Remarkable alternations were observed in concentration of elements like Cl, K, Ca, Mn, Fe, Cu, Zn. The pattern of enhancement of elemental concentration corresponds to the progression of the disease. Additionally, our present data reflect probable correlation between alteration in trace elemental status and other pathological syndromes associated with Leishmaniasis. The possibility of considering trace elements as a diagnostic marker for a better understanding of the disease is discussed. (author)

  18. Determination of trace elements in food reference materials by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Cho, K. H.; Park, K. W.; Zeisler, R.

    2005-01-01

    Two biological Certified Reference Materials (CRMs), KRISS 108-04-001 (ouster tissue) and 108-05-001 (water dropwort stem), were prepared by Korea Research Institute of Standards and Science (KRISS) during FY '01. The certified values of these materials had been determined by Isotope Dilution Mass Spectrometry (IDMS) for six elements (Cd, Cr, Cu, Fe, Pb and Zn). Additional analytical works are now progressing to certify the concentrations of a number of the environmental and nutrimental elements in these CRMs. The certified values in a CRM are usually determined by using a single primary method with confirmation by other method(s) or using two independent critically-evaluated methods. Instrumental Neutron Activation Analysis (INAA) plays an important role in the determination of certified values as it can eliminate the possibility of common error sources resulting from sample dissolution. In this study INAA procedure was used in determination of 23 elements in these two biological CRMs to acquire the concentration information and the results were compared with KRISS certified values

  19. Determination of trace elements in cardiotonic drugs by neutron activation analysis

    International Nuclear Information System (INIS)

    Kanias, G.D.

    1980-01-01

    Potassium may be intimately involved in the action of cardiac glycosides. Chlorine and potassium also act as diuretics. The elements chlorine, manganese, potassium and sodium are determined by instrumental neutron activation analysis in the cardiotonic drugs (pills, injections, water solutions). It has been found that there is a wide variation among the different values for manganese, sodium and chlorine while for potassium values are relatively constant. Results are discussed from the pharmacological point of view. It is proposed to study the role of manganese in cardiotonic drugs as well as the effect of potassium addition in oral pharmaceutical form of cardiotonic drugs in decreasing the toxicity of cardiac glycosides. (author)

  20. Quantitative analysis of selected minor and trace elements through use of a computerized automatic x-ray spectrograph

    International Nuclear Information System (INIS)

    Fabbi, B.P.; Elsheimer, H.N.; Espos, L.F.

    1976-01-01

    Upgrading a manual X-ray spectrograph, interfacing with an 8K computer, and employment of interelement correction programs have resulted in a several-fold increase in productivity for routine quantitative analysis and an accompanying decrease in operator bias both in measurement procedures and in calculations. Factors such as dead time and self-absorption also are now computer corrected, resulting in improved accuracy. All conditions of analysis except for the X-ray tube voltage are controlled by the computer, which enhances precision of analysis. Elemental intensities are corrected for matrix effects, and from these the percent concentrations are calculated and printed via teletype. Interelement correction programs utilizing multiple linear regression are employed for the determination of the following minor and trace elements: K, S, Rb, Sr, Y, and Zr in silicate rocks, and Ba, As, Sb, and Zn in both silicate and carbonate rock samples. The last named elements use the same regression curves for both rock types. All these elements are determined in concentrations generally ranging from 0.0025 percent to 4.00 percent. The sensitivities obtainable range from 0.0001 percent for barium to 0.001 percent for antimony. The accuracy, as measured by the percent relative error for a variety of silicate and carbonate rocks, is on the order of 1-7 percent. The exception is yttrium

  1. Some investigation on trace elements content of Iranian breads using neutron activation analysis and atomic absorption spectroscopy

    International Nuclear Information System (INIS)

    Gharib, A.; Fatemi, K.; Moazezi, A.; Mahmoodzadeh, A.; Koushkestani, R.

    1988-01-01

    Since bread is consumed as a principal dietary staple by the majority of Iranian communities, actual natural portion of required protein and energy are provided via bread. Therefore, with respect to this matter, a considerable amount of needed minerals must also be met through this way. Literature survey indicates some elemental deficiencies as the result of consumption of bread in Iran. On the other hand, essentiality of these elements to human which are mostly in the range of trace amounts, makes this investigation very much important and interesting from both sides, nutritionally and instrumentally. To meet the above requirements, applications of very sensitive analytical tools are unavoidable. Hence, atomic absorption spectroscopy and neutron activation analysis both RNAA and INAA are employed. Results are controversial and constructive

  2. Concentration of trace elements in marine organisms

    International Nuclear Information System (INIS)

    Ishii, Takaaki; Suzuki, Hamaji; Iimura, Mitsue; Koyanagi, Taku

    1976-01-01

    Information on the quality and quantity of stable trace elements in marine environments is frequently required to analyze the radioecological behavior of radionuclides released from nuclear facilities into the sea. In the present work, special attention was concentrated in determination of stable Mn, Fe, Co, Zn, Rb and Cs in marine organisms to estimate the concentration factors for these elements and corresponding radionuclides. Marine organisms (fishes, marine invertebrates and seaweeds) were collected at the seashore of Ibaragi prefecture and provided for chemical analysis after dry-ashing and wet-ashing. Atomic absorption spectrophotometry and neutron activation analysis were applied to determine the concentration of elements. The concentration of stable elements in fish muscle was independent on species of the fishes though slightly higher trends were observed in ''Usumebaru'', Sebastes nivosus for Cs, ''Ishimochi'', Nibea mitsukurii for Zn and Fe compared with other species. The concentration of Co, Zn and Fe in muscle of marine invertebrates was one order of magnitude higher than fish muscles especially in shellfishes for Co. Seaweeds showed peculiar species specificity for the concentration of stable trace elements and remarkable differences was observed between the species even among the same genus. (auth.)

  3. Evaluation of some procedures relevant to the determination of trace elemental components in biological materials by destructive neutron activation analysis

    International Nuclear Information System (INIS)

    Berry, D.L.

    1979-01-01

    The development of a simplified procedure for the analysis of biological materials by destructive neutron activation analysis (DNAA) is described. The sample manipulations preceding gamma ray assay were investigated as five specific stages of processing: (1) pre-irradiation treatment; (2) sample irradiation; (3) removal of the organic matrix; (4) removal of interfering radioactivities; and (5) concentration and separation of analyte activities. Each stage was evaluated with respect to susceptibility to sample contamination, loss of trace elemental components, and compatibility with other operations in the overall DNAA procedures. A complete DNAA procedure was proposed and evaluated for the analysis of standard bovine liver and blood samples. The DNAA system was effective for the determination of As, Cu, Fe, Hg, Mo, Rb, Sb, Se, and Zn without yield determinations and with a minimum turn-around time of approximately 3 days

  4. Evaluation of some procedures relevant to the determination of trace elemental components in biological materials by destructive neutron activation analysis

    Energy Technology Data Exchange (ETDEWEB)

    Berry, D.L.

    1979-01-01

    The development of a simplified procedure for the analysis of biological materials by destructive neutron activation analysis (DNAA) is described. The sample manipulations preceding gamma ray assay were investigated as five specific stages of processing: (1) pre-irradiation treatment; (2) sample irradiation; (3) removal of the organic matrix; (4) removal of interfering radioactivities; and (5) concentration and separation of analyte activities. Each stage was evaluated with respect to susceptibility to sample contamination, loss of trace elemental components, and compatibility with other operations in the overall DNAA procedures. A complete DNAA procedure was proposed and evaluated for the analysis of standard bovine liver and blood samples. The DNAA system was effective for the determination of As, Cu, Fe, Hg, Mo, Rb, Sb, Se, and Zn without yield determinations and with a minimum turn-around time of approximately 3 days.

  5. Biomonitoring of air pollution in Jamaica through trace-element analysis of epiphytic plants using nuclear and related analytical techniques

    International Nuclear Information System (INIS)

    Vutchkov, Mitko

    2001-01-01

    The main goal of the Coordinated Research Project (No:9937/R0), entitled 'Biomonitoring of Air Pollution in Jamaica Through Trace-Element Analysis of Epiphytic Plants Using Nuclear and Related Analytical Techniques', is to identify and validate site specific epiphytic plants for biomonitoring the atmospheric pollution in Jamaica using nuclear analytical techniques at the International Centre for Environmental and Nuclear Sciences (ICENS). The specific objectives for the second year of the project were: Development of HOP for sampling epiphytic plants in Jamaica; Sampling design and sample collection; Sample preparation and analysis; Development of an in-house SRM and participation in the NAT-5 inter-laboratory study; Data analysis and interpretation of the results; Development of a work plan of the third year of the project

  6. Remediation using trace element humate surfactant

    Science.gov (United States)

    Riddle, Catherine Lynn; Taylor, Steven Cheney; Bruhn, Debra Fox

    2016-08-30

    A method of remediation at a remediation site having one or more undesirable conditions in which one or more soil characteristics, preferably soil pH and/or elemental concentrations, are measured at a remediation site. A trace element humate surfactant composition is prepared comprising a humate solution, element solution and at least one surfactant. The prepared trace element humate surfactant composition is then dispensed onto the remediation site whereby the trace element humate surfactant composition will reduce the amount of undesirable compounds by promoting growth of native species activity. By promoting native species activity, remediation occurs quickly and environmental impact is minimal.

  7. Source Attribution of Cyanides using Anionic Impurity Profiling, Stable Isotope Ratios, Trace Elemental Analysis and Chemometrics

    Energy Technology Data Exchange (ETDEWEB)

    Mirjankar, Nikhil S.; Fraga, Carlos G.; Carman, April J.; Moran, James J.

    2016-01-08

    Chemical attribution signatures (CAS) for chemical threat agents (CTAs) are being investigated to provide an evidentiary link between CTAs and specific sources to support criminal investigations and prosecutions. In a previous study, anionic impurity profiles developed using high performance ion chromatography (HPIC) were demonstrated as CAS for matching samples from eight potassium cyanide (KCN) stocks to their reported countries of origin. Herein, a larger number of solid KCN stocks (n = 13) and, for the first time, solid sodium cyanide (NaCN) stocks (n = 15) were examined to determine what additional sourcing information can be obtained through anion, carbon stable isotope, and elemental analyses of cyanide stocks by HPIC, isotope ratio mass spectrometry (IRMS), and inductively coupled plasma optical emission spectroscopy (ICP-OES), respectively. The HPIC anion data was evaluated using the variable selection methods of Fisher-ratio (F-ratio), interval partial least squares (iPLS), and genetic algorithm-based partial least squares (GAPLS) and the classification methods of partial least squares discriminate analysis (PLSDA), K nearest neighbors (KNN), and support vector machines discriminate analysis (SVMDA). In summary, hierarchical cluster analysis (HCA) of anion impurity profiles from multiple cyanide stocks from six reported country of origins resulted in cyanide samples clustering into three groups: Czech Republic, Germany, and United States, independent of the associated alkali metal (K or Na). The three country groups were independently corroborated by HCA of cyanide elemental profiles and corresponded to countries with known solid cyanide factories. Both the anion and elemental CAS are believed to originate from the aqueous alkali hydroxides used in cyanide manufacture. Carbon stable isotope measurements resulted in two clusters: Germany and United States (the single Czech stock grouped with United States stocks). The carbon isotope CAS is believed to

  8. Trace elements determination in silicon and ferrosilicon reference materials by instrumental neutron activation analysis method

    International Nuclear Information System (INIS)

    Moreira, Edson Goncalves; Vasconcellos, Marina Beatriz Agostini; Saiki, Mitiko; Iamashita, Celia Omine

    2002-01-01

    The use of certified reference materials, CRM, is of uppermost importance in the rastreability realization of the measurement process. At times, CRM use is restricted by the non existence of a suitable CRM with similarity to the sample in respect to matrix composition or with element levels in different orders of magnitude. IPT Chemical Division launched a project to prepare a metallic silicon CRM, due to the requirements of the industries in this field. To characterize this new CRM, IPEN Nuclear Reactor Center is able to perform instrumental neutron activation analysis, INAA, a very suitable method for silicon matrix samples because they produce basically the short lived radionuclide 3 1 Si under thermal neutrons flux, which after radioactive decay, does not interfere in the determination of other elements. In this paper, it is presented the determination of As, Br, Co, Cr, K, Eu, Fe, La, Mn, Na Nb, Sb, Sm, Sc, Th, Tb, U, V, W and Yb in silicon CRM NBS SRM 57; ferrosilicon CRM IPT 56; IPT 70; NBS SRM 58a; NBS SRM 59a and silicon RM under preparation IPT 132. From the results, the accuracy and the precision of the process were assessed. (author)

  9. The study of the trace element in organisms by neutron activation analysis, 1

    International Nuclear Information System (INIS)

    Shinogi, Masaki; Murai, Yasuko; Mori, Itsuhiko; Takeuchi, Takayuki.

    1974-01-01

    Examinations were made on optimal experimental conditions for instrumental determination of various elements in cannabis by neutron activation analysis, without any radiochemical separation, and the following conditions were found to be useful. Irradiation samples to be used are about 300 mg of the leaves or stem bark, and about 100 mg of the root. For soil sample, about 50 mg is used for the determination of short half-life nuclides and about 300 mg for long half-life nuclides. For short half-life nuclides, the samples are irradiated for 1 min, activity is measured for 200 sec after a decay of 3 min, and for 400 sec after a decay of 10 min. For long half-life nuclides, the samples are irradiated for 60 min and the activites are measured for 4 K sec after 1 week and for 10 K sec after 1 month. Use of supersonic waves is also convenient for cleansing of the samples. Thirty-five kinds of interesting elements were determined by this method from cannabis cultivated in Maizuru area. (auth.)

  10. Trace element analysis of Alexander the Great's silver tetradrachms minted in Macedonia

    International Nuclear Information System (INIS)

    Kallithrakas-Kontos, N.; Katsanos, A.A.; Touratsoglou, J.

    2000-01-01

    The coinage of Alexander the Great presents a special interest because of its international character in the frame of the ancient times. At least 31 mints (from Aigai to Babylon and from Pella to Alexandreia) operated in the vast state, which was created by Alexander in just over 10 years (334-323 BC). Impressive quantities of tetradrachms were consequently minted for the economic affairs of an expanding state. The mints continued to be active and after the premature death of the Macedonian king, producing among others and tetradrachms in his name. The elemental chemical composition of silver tetradrachms minted in Amphipolis as well as in other Macedonian Greek cities was analysed by energy dispersive X-ray fluorescence (EDXRF), and 12 elements were determined. The problem of the patina (silver corrosion layer) effects on the results was examined by analysis before and after the corrosion product removal. From the results of the chemical composition, a similar numismatic policy is deduced for all the analysed coin as well as metal provenance indications for some of the coins

  11. Toxic trace element content of local fruits using instrumental neutron activation analysis (INAA)

    International Nuclear Information System (INIS)

    Siddique, N.; Ahmed, S.; Rahman, A; Waheed, S.; Chaudhary, M.M.; Qureshi, I.H.

    1997-01-01

    An important route of entry of environmental contaminants into the human system is through food intake. To study the effect of environmental pollution on the food chain, base line levels of toxic element content of commonly available food articles must be established. This study was undertaken to determine the toxic meal content of Pakistani fruits. The techniques of instrumental Neutron Activation Analysis (INAA) and Atomic Absorption Spectrometry (AAS) were employed for this purpose. Fourteen fruits apple, apricot, banana, data guava, kino, mango, melon, orange, peach, pear, plum, pomegranate and watermelon, as well as, the peels of apple and pear have been investigated and the results are discussed in this paper. The results were found to lie within 95 % confidence limit using Student's t test. Hg, As and Sb were detected, using INAA, in pear, pomegranate and water melon in low amounts (ppb levels) but were not detected in orange, plum and melon. Lesser amounts of toxic elements were detected in the peels of pear and high amounts were detected in apple peel as compared to the edible part of the fruit. Cadmium and lead were determined using Graphite Furnace atomic absorption Spectrometry. Cadmium was found to lie in the range of 18-42 ppb, in most fruits, whereas the amount of lead varied between 39-128 ppb. Lead was below detection limit in melon, guava, mango, and peach contained the highest amount of As, Cd, Hg and Pb. (author)

  12. Chemometric analysis of minerals and trace elements in Sicilian wines from two different grape cultivars.

    Science.gov (United States)

    Potortί, Angela Giorgia; Lo Turco, Vincenzo; Saitta, Marcello; Bua, Giuseppe Daniel; Tropea, Alessia; Dugo, Giacomo; Di Bella, Giuseppa

    2017-05-01

    Chemometric analysis are used for food authenticity evaluation, correlating botanical and geographical origins with food chemical composition. This research was carried out in order to prove that it is possible linked red wines to Nero d'Avola and Syrah cultivars of Vitis vinifera according to their mineral content, while the values of the physical and chemical parameters do not affect relevantly this discrimination. The levels of mineral elements were determined by ICP-OES and ICP-MS. Samples from cv Nero d'Avola had the highest content of Zn, Cr, Ni, As and Cd, whereas the highest mineral concentration in cv Syrah samples was represented by K, Mg, Cu, and Sb. The research highlights that it is possible linked red wines to Nero d'Avola and Syrah cultivars of V. vinifera according to their mineral contents, adding knowledge to the determination studies of the wine botanical origin.

  13. Trace elements in Turkish tea leaves determined by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Demiralp, R.

    1985-01-01

    The concentrations of the elements As, Sb, Zn, Co, which are closely related to human health and disorder, was determined by means of INAA in seven of the most commonly used brands of tea. Samples and standards were irradiated 10 min and 2 hrs at pneumatic system and central thimble in the TRIGA MARK-11 research reactor. After irradiation the activities were measured with a coaxial Ge detector coupled to a spectroscopic amplifier. A Cambera 90 model multichannel analyser with an 8K memory was used for pulse hight analysis. The system has a resolution of 2,0 KeV for 1332,5 KeV gamma ray of 60 Co with peak to Compton ratio of 43:1 and efficiency of 18 relative to the 3'' x 3'' NaI(Tl) crystal. Results of the study were presented

  14. Determination of trace elements in aerosols from the antarctic peninsula by neutron activation analysis

    International Nuclear Information System (INIS)

    Loureiro, A.L.M.

    1989-01-01

    In this work the neutron activation method was applied to carry out multielemental analysis in aerosols collected in the Brazilian Station 'Comandante Ferraz', located on King George Island, at the Antarctic Peninsula, during 1986 and 1987. The aerosols were collected on 0.45 μum Millipore-MF filter paper, type HA. The analytical method was based on the simultaneous irradiations of filters and synthetic standards in the IEA-R1 nuclear reactor under a thermal neutron flux of about 10 12 n cm -2 s -1 . The induced radioactivity was measured in a gamma ray spectrometer after suitable cooling times. Samples were irradiated twice, with irradiation times varying from 5 minutes to 24 hours. The elements Na, Al, Cl, K, Ca, Sc, V, Mn, Fe, Zn, Br, Sb, La, Au and Th were determined with concentration levels from ng/m 3 to pg/m 3 [pt

  15. Determination of trace cadmium and other elements in bone by epithermal neutron activation analysis

    International Nuclear Information System (INIS)

    Dowlati, R.; Jervis, R.E.

    1991-01-01

    Epithermal neutron activation analysis (ENAA) was applied to measure quantitatively Cd and other elements in bone samples from control and Cd-fed rats. This method was found to be non-destructive to the bone samples, with no sign of 'radiolytic charring' and was sensitive enough to detect and quantify Cd in bone samples at normal levels for mammals (viz. 0.5-1.0μg/g) and higher. Two different thermal neutron shield materials were utilized, namely cadmium and boron. The boron shield resulted in a 27% improvement in the detection limit of Cd in bone. The accuracy of ENAA for Cd was assessed by intercomparison with electrothermal atomic absorption spectrophotometry (ETAAS), and the results were in fair agreement (±23%) with those from ENAA. (author) 24 refs.; 5 tabs

  16. Measurement of trace cadmium and elements in bone by epithermal neutron activation analysis

    International Nuclear Information System (INIS)

    Dowlati, R.; Jervis, R.E.

    1991-01-01

    Epithermal neutron activation analysis (ENAA) was applied to measure quantitatively Cd and other elements in bone samples from control and Cd-fed rats. This method was found to be non-destructive to the bone samples, with no sign of 'radiolytic charring' and was sensitive enough to detect and quantify Cd in bone samples at normal levels for mammals (viz. 0.5-1.0 μg/g) and higher. Two different thermal neutron shield materials were utilized, namely cadmium and boron. The boron shield resulted in a 27% improvement in the detection limit of Cd in bone. The accuracy of ENAA for Cd was assessed by intercomparison with electrothermal atomic absorption spectrophotometry (ETAAS), and the results in fair agreement (±23%) with those from ENAA

  17. X-ray fluorescence analysis of K, Al and trace elements in chloroaluminate melts

    Science.gov (United States)

    Shibitko, A. O.; Abramov, A. V.; Denisov, E. I.; Lisienko, D. G.; Rebrin, O. I.; Bunkov, G. M.; Rychkov, V. N.

    2017-09-01

    Energy dispersive x-ray fluorescence spectrometry was applied to quantitative determination of K, Al, Cr, Fe and Ni in chloroaluminate melts. To implement the external standard calibration method, an unconventional way of samples preparation was suggested. A mixture of metal chlorides was melted in a quartz cell at 350-450 °C under a slightly excessive pressure of purified argon (99.999 %). The composition of the calibration samples (CSs) prepared was controlled by means of the inductively coupled plasma atomic emission spectrometry (ICP-AES). The optimal conditions for analytical lines excitation were determined, the analytes calibration curves were obtained. There was some influence of matrix effects in synthesized samples on the analytical signal of some elements. The CSs are to be stored in inert gas atmosphere. The precision, accuracy, and reproducibility factors of the quantitative chemical analysis were computed.

  18. Comparison of trace element contamination levels (Cu, Zn, Fe, Cd ...

    African Journals Online (AJOL)

    SERVER

    2008-03-18

    Mar 18, 2008 ... Chemical analysis of the trace elements in the soft tissues. The trace elements of interest (Cu, Zn, Fe, Pb, Cd) were then determined in the digested solutions, using Thermoelemental type. M6 brand of an atomic absorption Spectrometer equipped with a flame operated atomisation system and a deuterium ...

  19. Trace elements determination in municpal water supply in Damaturu ...

    African Journals Online (AJOL)

    This study examines the presence of trace elements in the municipal water supplies of Damaturu Metropolis, Yobe state. The trace elements were determined using standard methods for the examination of water and wastewater from the US Environmental Protection Agency (USEPA). The result of the analysis shows that ...

  20. Application of neutron activation analysis to the study of the variations of the concentration of trace elements in various organs of rat as a function of age

    International Nuclear Information System (INIS)

    Maziere, B.; Loc'h, C.; Stulzaft, O.; Gaudry, A.; Comar, D.

    1976-01-01

    In order to know the normal distribution of trace elements in rats as accurately as possible, the composition of different organs and body tissues by neutron activation analysis was determined in animals from 15 days to 22 months old. The experiment conditions were described. Normal concentrations for more than 20 trace elements were obtained, some of them being less than a tenth of a part per billion. The experiment has shown that variations in elemental concentrations in terms of age were a general phenomenon and that for some elements a steady state is apparently never attained

  1. Determination of trace elements in Stenopsyche griseipennis by neutron activation analysis

    Energy Technology Data Exchange (ETDEWEB)

    Nagatsuka, S.; Tanizaki, Y. (Tokyo Metropolitan Isotope Research Center (Japan))

    1981-05-01

    An instrumental neutron activation analysis was applied to the multielemental analysis of the Stenopsyche griseipennis taken from the head water area and the lower of Tama river. The dry Stenopsyche griseipennis were irradiated for 3 minutes and 12 hours in a thermal neutron flux 1.5 x 10/sup 12/ n.cm/sup -2/.sec/sup -1/ of TRIGA-II reactor of Rikkyo University. Thus, Al, Ca, Cl, Mn, V, Na, K, Br, La, Sm, Se, Cr, Ba, Cs, Sc, Rb, Zn, Co, Fe, and Sb could be analyzed. Analysis of the river water samples taken from the sampling points of the Stenopsyche griseipennis was carried out by the method given in the author's previous paper. The analytical results of Na, K, Zn and Se for the Stenopsyche griseipennis showed constant value independently of the river water quality, and Mn showed the different concentration between at the head water area and at the lower. On the other hand, the analytical results of Al, Fe, Sc, V, As, Sb, etc. showed wide range values. It can be considered that these elements were affected by taking up river sediment, and V, As and Sb concentrations in the Stenopsyche griseipennis at head water area showed larger values than those at the lower.

  2. Trace element metabolism in man and animals

    International Nuclear Information System (INIS)

    Kirchgessner, M.

    1977-01-01

    Uptake, distribution, storage, excretion of different trace elements and resulting disturbances are investigated in blood and organs in animal experiments and in human diagnostics with the aid of radioisotopes. Apart from this, untritional disturbances are mentioned. Finally, future aspects of physiological trace element examinations are listed. (AJ) 891 AJ [de

  3. Trace elements characterization of the hydrothermally deposited ...

    African Journals Online (AJOL)

    With the exception of higher barium contents in pelites, trace element contents in the psammitic and pelitic gneisses show some similarities while in the hydrothermally altered rocks where gemstones (tanzanite and green grossular) are localized reveal that the following trace elements: Ba, Cu, Mo, Ni, Rb, Sr, U, V and Zn ...

  4. Trace element analysis of mineral and tap water samples using total reflection x-ray fluorescence (TXRF)

    International Nuclear Information System (INIS)

    Mangala, M.J.; Korir, K.A.; Maina, D.M.; Kinyua, A.M.

    2000-01-01

    Results of trace element analysis by TXRF of tap water and various brands of bottled mineral water samples which are representative of local and imported brands sold in Nairobi are reported. The variation in elemental concentrations in water samples analyzed were as follows: potassium (K) 0.2 to 28.9 μg/ml; calcium (Ca) 2.2 to 120 μg/ml; titanium (Ti) 11 to 60 μg/l; manganese (Mn) 8 to 670 μg/l; iron (Fe) 31 to 540 μg/l; copper (Cu) 8 to 30 μg/l; zinc (Zn) 8 to 4730 μg/l; bromine (Br) 9 to 248 μg/l; rubidium (Rb) 10 to 40 μg/l and strontium (Sr) 10 to 1000 μg/l. Local mineral water samples contain higher levels of trace elements; manganese (Mn), zinc (Zn), bromine (Br), rubidium (Rb) and strontium (Sr) as compared to the imported brands. Principal component analysis of the results revealed three component loading factors clusters for: rubidium (Rb), strontium (Sr) and calcium (Ca); titanium (Ti), iron (Fe), bromine (Br), and zinc (Zn); zinc (Zn), manganese (Mn) and potassium (K) respectively. The percentage of total variance explained by the components was 31.4, 27.3, and 14.8 respectively. In this study, we also found that a limited spread of 5-6 mm for a 10 μl sample was achieved when the quartz sample carrier was dried in a low pressure (300 mbar) oven at 70 o C for 10 hours. (author)

  5. Analysis of trace element in intervertebral disc by Atomic Absorption Spectrometry techniques in degenerative disc disease in the Polish population

    Directory of Open Access Journals (Sweden)

    Andrzej Nowakowski

    2015-05-01

    This study is the first to our knowledge that profiles the elements in intervertebral disc in patients with degenerative changes. We have confirmed significant differences between the trace element contents in intervertebral disc and other tissue. It can be ground for further investigation.

  6. Use of neutron activation analysis to measure the variation in trace element concentrations in a coal seam

    International Nuclear Information System (INIS)

    Fardy, J.J.; Swaine, D.J.

    1985-01-01

    Trace element concentrations were measured by neutron activation on 57 run-of-mine coal samples from several locations in seven mines located in the Lithgow seam in the Western Coalfield, Sydney Basin. Results were tabulated as ratios of the highest to the lowest variance for each element

  7. Determination of trace elements in freshwater diatoms by neutron activation analysis

    Energy Technology Data Exchange (ETDEWEB)

    Nagatsuka, S.; Tanizaki, Y.; Yamazaki, M. (Tokyo Metropolitan Isotope Research Center (Japan))

    1982-02-01

    The instrumental neutron activation analysis was applied to the multielemental analysis of the freshwater diatoms taken from the head and the lower areas of Tama river. Dry samples of the diatoms were irradiated for 1 minute (for the measurement of short lived nuclides) by pneumatic tube of TRIGA-II reactor of Musashi Institute of Technology, and 12 hours (for the measurement of long lives nuclides) in F ring of TRIGA-II reactor of Rikkyo University. The analytical results of 20 elements in the samples were obtained, and the concentration of Ti showed high values in all the sample. Since it is considered that Ti is absent in algae, these high values indicate that appreciable amounts of river sediment were contained in the samples. Therefore, the analytical results were corrected for Ti contents in the samples. The concentrations of Mg, K, Zn, Mn and Co in the diatoms showed no difference between the two sampling points. The concentrations of Cr, V, As and Sb in the diatoms, however, showed difference between the two sampling points, depending on the river water quality. In Stenopsyche grisepennis, on the other hand, the concentrations of Mn and Co depend on the river water quality, and the concentrations of Cr depend on the amount of diatoms staying in the body. The concentrations of V, As and Sb in the Stenopsyche griseipennis are considered to depend both on the amount of diatoms and river sediment staying in the body.

  8. Metal and trace element assessment of sediments from Guarapiranga reservoir, Sao Paulo State, by neutron activation analysis

    International Nuclear Information System (INIS)

    Guimaraes, Guilherme M.; Favaro, Deborah I.T.; Franklin, Robson L.; Ferreira, Francisco J.; Bevilacqua, Jose E.

    2009-01-01

    Guarapiranga Reservoir is extremely important due to the fact that it is one of the main water reservoirs for South America's largest city, Sao Paulo, Brazil. Guarapiranga Basin is located within the Metropolitan Region of Sao Paulo - RMSP, and occupies an area of approximately 630 km 2 , and the reservoir itself is located in the northern part of the basin occupying approximately 26 km 2 . This reservoir is characterized by environmental impacts from urban invasion, industrial and sewage wastes, all of which seriously affect its water quality. Due to its vulnerability CETESB (Environmental Control Agency of the Sao Paulo State) regularly monitors the contamination levels of waters and once a year sediment samples. In order to better understand geochemical and environmental processes and their possible changes due to anthropogenic activities trace metals analyses and their distribution in sediments are commonly undertaken. The present study reports results concerning the distribution of some major (Fe, K and Na), trace (As, Ba, Br, Co, Cr, Cs, Hf, Hg, Rb, Sb, Sc, Ta, Tb, Th, U and Zn) and rare earth (Ce, Eu, La, Lu, Nd, Sm, Tb and Yb) elements in sediments from the Guarapiranga Reservoir. Multielementar analysis was carried out by instrumental neutron activation analysis (INAA). Multielemental concentrations in the sediment samples were compared to NASC (North American Shale Composite) values. The concentration values for metals As, Cr and Zn in the sediment samples were compared to the Canadian Council of Minister of the Environment (CCME) oriented values (TEL and PEL values) and adopted by CETESB. (author)

  9. µ-XRF Analysis of Trace Elements in Lapis Lazuli-Forming Minerals for a Provenance Study.

    Science.gov (United States)

    Angelici, Debora; Borghi, Alessandro; Chiarelli, Fabrizia; Cossio, Roberto; Gariani, Gianluca; Lo Giudice, Alessandro; Re, Alessandro; Pratesi, Giovanni; Vaggelli, Gloria

    2015-04-01

    This paper presents new developments on the provenance study of lapis lazuli started by our group in 2008: during the years a multi-technique approach has been exploited to obtain minero-petrographic characterization and creation of a database considering only rock samples of known provenance. Since the final aim of the study is to develop a method to analyze archeological findings and artworks made with lapis lazuli in a completely non-invasive way, ion beam analysis techniques were employed to trace the provenance of the raw material used for the production of artifacts. Continuing this goal and focusing the analysis on determination of more significant minero-chemical markers for the provenance study of trace elements in different minerals, the method was extended with the use of micro X-ray fluorescence (µ-XRF), to test the potential of the technique for this application. The analyzes were focused on diopside and pyrite in lapis lazuli samples of known provenance (Afghanistan, Tajikistan, and Siberia). In addition, µ-XRF data were compared with micro proton-induced X-ray emission (µ-PIXE) results to verify the agreement between the two databases and to compare the analytical performance of both techniques for this application.

  10. The application of chelating resin to the elimination of interferences in the analysis of trace hazardous elements

    International Nuclear Information System (INIS)

    Yamazaki, Masao; Goto, Michiko; Nakagawa, Seiko; Hukuchi, Ryouichi; Shirako, Sadaharu

    2005-01-01

    In general, digestion with nitric and sulfuric acids are applied in the analysis of trace elements in solid materials like industrial products and soils. This causes the digested solution to contain high concentrations of sulfate ion. In addition, silicate, chloride and other interferences, which are contained in the material itself, can also be included. These interfering matrices are separated generally through solvent extraction. In stead of the solvent extraction method, we applied the solid phase extraction method using chelating resin, which has a functional group of iminodiacetic acid, for the analysis of trace hazardous metals such as Cd and Pb in industrial products, soils, and other materials containing high concentrations of matrix components. In the presence of high concentrations of interfering ions, over 80% of Cd and Pb and Pb were extracted, with one exception that the recovery of Cd from seawater decreased to 60-30% in the presence of 19g/L of chloride ion. On the other hand, Cr, As and Se were extracted at a low recovery rate with this type of chelating resin. (author)

  11. Comparative Analysis on the Effect of Plantago Species Aqueous Extracts on Tissue Trace Element Content in Rats.

    Science.gov (United States)

    Gatiatulina, Evgenia R; Nemereshina, Olga N; Suliburska, Joanna; Nagaraja, Tejo Prakash; Skalnaya, Anastasia A; Nikonorov, Alexandr A; Skalny, Anatoly V; Tinkov, Alexey A

    2017-09-01

    The primary objective of this study is to assess the influence of water extracts of Plantago major L., Plantago lanceolata L., and Plantago maxima Juss. ex Jacq. leaves on tissue trace element content in healthy adult Wistar rats. Twenty-eight female Wistar rats consumed pure drinking water or one of the three aqueous extracts of Plantago for 1 month. The extracts and liver, serum, hair, and adipose tissue of the rats were examined for trace element contents using inductively coupled plasma mass spectrometry. The aqueous extracts of Plantago species contained significant levels of trace elements, which were highest in P. lanceolata and P. major. The administration of every extract led to an increase in V and Si levels in the rats. At the same time, the consumption of P. lanceolata aqueous extract resulted in the accumulation of toxic elements (As, Pb) in the rats' tissues. Despite the rather high concentration of heavy metals in the P. major leaf extract, its administration did not result in the accumulation of these elements. In turn, P. maxima extract induced a significant decrease in the tissue levels of Al, Cr, I, Li, and Mn in the rats. The beneficial effect of the P. major and P. maxima preparations may be at least partially associated with the increased supply of essential trace elements, whereas the use of P. lanceolata may be harmful due to the possibility of heavy metal overexposure.

  12. Study of distribution and differential accumulation of trace elements in plant leaves using neutron activation analysis

    International Nuclear Information System (INIS)

    Koyama, Mutsuo; Takada, Jitsuya; Shirakawa, Masahiro; Katayama, Koshi.

    1983-01-01

    Plant leaves were collected from geologically different forests three times from April to May, from August to September, and from October to November. Although the concentration of inorganic elements showed the constant distribution pattern in the same trees, the distribution pattern was peculiar to plant species and elements. Ia and halogen groups were prominent in herbaceous plants, while IIa group, except for Ba accumulated into pteridophyta, was prominent in woody plants. Of the transition metal elements, Mn was highly accumulated in Tea senensis. The high concentration of Mn was more marked in Araliaceae than in Tea senensis. Specific high concentrations of Fe and Co were noted in Ecephorbiaceae, Zn and Cd in Aquifoliaceae, and Al, rare earth elements and Ra in Gleichenia japonica and Dicranopteris dichotome. (Namekawa, K.)

  13. Analysis of trace elements in medicinal plants with energy dispersive X-ray fluorescence

    International Nuclear Information System (INIS)

    Ekinci, N.; Polat, R.; Budak, G.; Ekinci, R.

    2004-01-01

    Mankind still depend on traditional herbal medicine for the treatment of various diseases and ailments. Elemental composition and concentration of medicinal plants have been investigated by energy dispersive X-ray fluorescence. The elements present in medicinal plants are P, Cl, K, Ca, S, Al, Ti, V, Rb, Sr, Zr, Nb, Mo, In, Sn, I and Ce. The physical basis of the used analytical method, the experimental set up and the procedure of sample preparation are presented. (author)

  14. Trace elements in airborne particles in internal industrial environments: spectrometric analysis of x-ray fluorescence (XRF)

    International Nuclear Information System (INIS)

    Salazar Matarrita, Alfonso

    2001-01-01

    Fluorescence spectroscopy x-ray, is a technique of non-destructive analysis, that allows quantitative determination of the absolute concentration of chemical elements that make up a given matrix. The detected elements depend on atomic number and energy of the secondary target used for irradiation of samples. X-rays are detected and counted in a spectroscopy system based on a multichannel analyzer, that discriminates by energy and form a spectrum of independent photopeaks, whose energy identifies the element and its intensity is proportional to its concentration. The quantification requires the irradiation and counting of a set of pattern comparators, of the same elements identified in the samples. The x-ray emission shows only during the time that the selected sample is subjected to irradiation by x-ray tube. This irradiation does not change the structure nor the chemical composition of the matrix, so the sample remains unchanged, after irradiation. This condition non-destructive characterizes the fluorescence x-ray. The trace elements present in airborne particles, are determined and collected on a Nuclepore filter. The collection sites selected are: Taller de Mecanica de Precision de la Escuela de Fisica, Universidad de Costa Rica; Taller J. V. G. Precision, San Antonio de Coronado; Taller de Muflas, MUFLASA, Alto de Guadalupe; Industria Silvania S. A., Pavas. In addition, it is attached the service rendered to the enterprise Sellos Generales S. A. The working conditions and physical conditions of facilities were considered. An aerosol sampler with a temporal variation was used. Irradiation of samples and an evaluation of the concentrations have been made. (author) [es

  15. Changes of trace element concentrations in vegetables during the usual food processing in the household found out by means of activation analysis

    International Nuclear Information System (INIS)

    Schelenz, R.

    1981-01-01

    The influence of processing of various vegetables and potatoes (cleaning, cutting, washing, cooking, steam-cooking) on the concentration of ingestion-physiologically important mineral- and trace elements has been studied by means of instrumental activation analysis. The leaching effects play a less important role in steam-cooking. Than in normal cooking. The most important loss already occurs when preparing the vegetables for cooking. This applies especially also to the essential trace elements; but also toxic elements such as arsenic are greatly reduced during this process. (RB) [de

  16. Temporal and diurnal analysis of trace elements in the Cryospheric water at remote Laohugou basin in northeast Tibetan Plateau.

    Science.gov (United States)

    Dong, Zhiwen; Kang, Shichang; Qin, Dahe; Qin, Xiang; Yan, Fangping; Du, Wentao; Wei, Ting

    2017-03-01

    An evaluation of glacial meltwater chemistry is needed under recent dramatic glacier melting when water resources might be significantly impacted. This study investigated trace elements variation in the meltwater stream, and its related aquatic environmental information, at the Laohugou (LHG) glacier basin (4260 m a.s.l.) at a remote location in northeast Tibetan Plateau. We focused on the spatial, temporal and diurnal change of trace elements during the glacier ablation period. Results showed evident elements spatial difference on the glacier surface meltwater, as most of the elements showed increased concentration at the terminus compared to higher elevations sites. Dominant elements in the meltwater were Ba, Sr and Cr, whereas elements with high enrichment factors (EFs) were Sb, Ni, Mo and Zn. Temporal change of some trace elements concentration (e.g. Sc, Cu, and Rb) indicated increasing trend with accelerated snow-ice melting, whereas others (e.g. Ni, Zn, and Pb) showed decreasing trend. We find that, trace elements showed evident diurnal change and a peak value of concentration was observed each day at about 15:00-17:00, and the diurnal change was influenced by runoff level and pH. Moreover, EFs calculations revealed that heavy metals were partially originated from regional anthropogenic sources. Overall, the accelerated diurnal and temporal snow-ice melting (with high runoff level) were correlated to increased elemental concentration, pH, EC and elemental change mode, and thus this work is of great importance for evaluating the impacts of accelerated glacier melting to meltwater chemistry and downstream ecosystem in the northeast Tibetan Plateau. Copyright © 2016 Elsevier Ltd. All rights reserved.

  17. Application of spectroscopic techniques of analysis for the determination of trace elements concentrations in some sudanese food items

    International Nuclear Information System (INIS)

    Ahmed, A. N.; Ali, A.H.; Eltayeb, M. A.; Ahmed, M.M.O

    2004-01-01

    The objectives of this study were to determine the levels of the mineral nutrients, especially of trace elements, in some food items commonly consumed in sudan and to compare the results of this work with local and inter nation data. to achieve these objectives.Food samples were collected from different localities in sudan, and the samples were prepared for analysis using dry ashing and wet digestion. Atomic absorption spectroscopy (Aas), X-ray florescence spectroscopy (XRF), flame photometry and colorimetry were used for the determination of the concentrations of elements in the samples. Samples were ashed using muffle furnace at temperature 55 degree C. The quality of the data was verified by the analysis of standard reference materials TDD-Id and hay-9. The levels of the elemental contents (Br,Ca,Co,Cu,Fe,Mg,Mn,P,Pb,Na,Rb,Sr, and Zn) were determined in legumes, cereals, oil seeds, flour and cereal products, vegetables, fruits, milk and milk products, egg, meats and fish, and oils and fats. The sudanese food items analyzed were found to contain considerable ranges of nutrients as follows:-concentration levels for some of these elements Ca, Cu and Fe show values which were higher in fruits (4709,21, and 633 ppm, respectively), and lower in oils and fat s (25, 2, and 11 ppm, respectively). Pb and Mn were higher in flour and cereals products (4 and 34 ppm, respectively) and lower in fruits (1 ppm) and meats and fish (1 ppm and 4 ppm, respectively ). Na and Zn were higher in flour and cereals products and legumes (4970 and 39 ppm, respectively). The values obtained agree, in general, with data available from other countries. Variations were observed among certain varieties of food. (Author)

  18. Trace elements as paradigms of developmental neurotoxicants

    DEFF Research Database (Denmark)

    Grandjean, Philippe; Herz, Katherine T

    2015-01-01

    Trace elements have contributed unique insights into developmental neurotoxicity and serve as paradigms for such adverse effects. Many trace elements are retained in the body for long periods and can be easily measured to assess exposure by inexpensive analytical methods that became available...... neurotoxicants that provide a reference for other substances that may have similar adverse effects. Less evidence is available on manganese, fluoride, and cadmium, but experience from the former trace elements suggest that, with time, adverse effects are likely to be documented at exposures previously thought...

  19. Forensic identification of trunk mat by trace element analysis of single fiber with laser ablation ICP-MS

    International Nuclear Information System (INIS)

    Hiroma, Yuki; Nakai, Izumi; Hokura, Akiko

    2010-01-01

    The application of LA-ICP-MS (laser ablation inductively coupled plasma mass spectrometry) to the chemical characterization of single trunk mat fibers made of PET was investigated in order to establish a forensic analytical method for the discrimination of samples of different origins. The analytical conditions of LA-ICP-MS equipped with a 213 nm Nd : YAG laser were optimized to analyze trace elements, such as Cu, Sb, and Ba at ppm levels. A total of 31 samples produced by 7 car manufactures in Japan were used for analysis. The concentrations of Li, Mg, Al, P, Ca, Ti, Co, Cu, Ge, Nb, Sb, Ta, and Pb were successfully measured from a single fiber sample with a diameter of ca. 20 μm. It was possible to discriminate all 31 samples based on the analytical results of a single fiber by LA-ICP-MS combined with those of FT-IR and SEM-EDS. LA-ICP-MS has good analytical sensitivity, and requires a much shorter preparation time and a smaller sample size than any other conventional element analysis methods. This paper demonstrates for the first time that this method is practically useful as a powerful tool for the forensic identification of a single trunk mat fiber. (author)

  20. PIXE analysis of trace elements in human hair of patients with liver disorders

    International Nuclear Information System (INIS)

    Bolormaa, O.; Tsuji, M.; Kawasaki, K.; Narantsetseg, S.; Hattori, T.

    2006-01-01

    Human hairs of cirrhosis, acute viral hepatitis patients and healthy people in Ulaanbaatar, capital city of Mongolia, were analyzed for the presence of heavy elements by PIXE spectrometry using 2.5 MeV proton beam at the Tokyo Institute of Technology Van de Graaff Laboratory. The samples were dissolved in a mixture of nitric acid and hydrogen peroxide. Then a 20μl aliquot was dropped on a Nuclepore Track-etch Membrane. The IAEA Reference Hair IAEA-086 certified reference material was used in order to verify accuracy of the method and the results were in good agreement with the certified values. To determine the interaction among nine elements in hair, correlation coefficients were evaluated for several pairs of elements. in the group of healthy control, no correlation between elements was identified. Opposite to this, the strong positive correlations were observed for Zn and Ca or Fe; Mn and Ca or Ti; Sr and Zn or Fe in the patients hair. In the present study, the mean concentrations of Ca, Ti, As and Sr in Mongolian patients were higher than those in the hair of normal people in Japan, Mongolia, Iran and Indonesia. The levels of Cu, Zn and Mn concentration in hair of normal people were almost the same for all the cohorts. (Author)

  1. Use of activation analysis method for determining trace elements in human nail clippings

    International Nuclear Information System (INIS)

    Aguiar, Amilton Reinaldo; Saiki, Mitiko

    1999-01-01

    This work presents results obtained in nail clipping samples analyses. These nail samples were collected from healthy group of individuals and from patients with cystic fibrosis disease. Irradiation of nail clippings was carried out with a thermal neutron flux from 10 11 to 10 13 n.cm -2 .s -1 at the IEA-R1m nuclear research reactor and the elements Al, As, Br, Ca, cd, Cl, Co, Cr, Cu, Fe, K, Mg, Mn, Na, Se and Zn were determined. The results obtained for healthy group were within the range of concentrations published, for normal population. However for several elements, the group of patients presented higher concentrations than those presented for healthy individuals. The precision and the accuracy of the results were evaluated by analyzing reference materials NIST 1577b Bovine Liver and 1566a Oyster Tissue. (author)

  2. Trace Element Levels in Congenital Hypogonadotrophic Hypogonadism.

    Science.gov (United States)

    Aydogdu, A; Haymana, C; Soykut, B; Erdem, O; Basaran, Y; Baskoy, K; Dinc, M; Taslipinar, A; Sonmez, A; Bolu, E; Azal, O

    2016-05-01

    Cardiometabolic diseases are prevalent in hypogonadism. The pathophysiologic mechanism of increased cardiometabolic risk in hypogonadal patients is not clear. Recently, trace elements have been linked to the development of chronic disease especially cardiovascular disease. We investigated the trace element levels in an unconfounded population of congenital hypogonadotrophic hypogonadism (CHH) and also searched for the relationship with metabolic risk factors. A total of 89 patients with CHH (mean age 21.8 ± 2.0 years) and 80 healthy control subjects (mean age 21.3 ± 1.1 years) were enrolled. The demographic parameters, homeostatic model assessment of insulin resistance (HOMA-IR) levels and plasma zinc, copper, and selenium levels, were measured in patients and healthy controls. The patients had higher waist circumferences (p = 0.014), triglyceride (p = 0.04), insulin (p = 0.004), HOMA-IR levels (p = 0.001), and lower selenium (p = 0.049), zinc (p = 0.004), and copper (p = 0.012) levels when compared to the healthy controls. There was a significant relationship between zinc levels and HOMA-IR levels (p = 0.015). In the regression analysis, zinc levels were independently associated with the calculated HOMA-IR levels (p = 0.015). The results of the present study show that plasma selenium, zinc, and copper levels are decreased in patients with CHH. Also, plasma zinc levels are independently associated with insulin resistance in patients with hypogonadism. Long-term follow-up studies are warranted to investigate the effect of trace elements on the increased cardiometabolic risk in hypogonadism.

  3. Determination of the minor and trace elements in Biriniwa's tin pyrite and ornamental lead/zinc ore using neutron activation analysis

    Directory of Open Access Journals (Sweden)

    A.O. Adebayo

    2002-12-01

    Full Text Available Preliminary results of analysis of two common decorative/ornamental minerals analysed for minor and trace elements with the neutron activation analysis technique are discussed. The samples of interest were the Biriniwa tin pyrite, which the local indigenous used to paint their huts and the ornamental lead which women use to adorn their eyelashes nation-wide. These samples were irradiated along the certified reference sample, CANMET-BLI, with thermal neutron at the Julich Reactor Centre, Julich, Germany. The prominent elements determined in the ornamental lead included zinc (35.8%, iron (6.15%, Na, Sb, Cd, Hg, Ag and Co at trace level (μg g-1. Tin pyrite sample was found to contain traces of Na, K, As, Br, Sb, Fe, La, Nd, Sm and Ce as the prominent impurities. Lead and tin, the major elements, respectively, of the lead/zinc ore and tin pyrite samples were determined by classical methods.

  4. Trace elements in ancient ceramics: Pt.4

    International Nuclear Information System (INIS)

    Li Huhou; Sun Yongjun; Zhang Xiangdong

    1987-01-01

    In the last period of Tong Dynasty, Jingdezhen began its production of ceramics. During the Song Dynasty, the ceramic industry greatly developed and produced fine white ware at Hutian. In the Yuan Dynastry, Hutian became the centre of production making the world famous blue and white wares. Here are reported results of analyses of ancient porcelians of Hutian in Jiangdezhen by reactor neutron activation analysis. The results show that the patterns of eight rare earth elements are apparently different for products in different periods, indicating that methods for producing ceramics or kinds of clay used were different. The contents of some other trace elements such as hafnium, tantalum, thorium and uranium show the same regularity in difference of composition also

  5. Determination of trace elements in Pre-Hispanic ceramics from Chile's Central Zone using instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Andonie, O; Munoz, L; Kohnnenkamp, I; Falabella, F

    2000-01-01

    The determination of the element composition in archaeological ceramics is an often unexplored potential, that could provide a unique set of data to verify regional economic and socio-political hypotheses. By chemically defining the elements in these materials, their manufacturing and production centers may be identified, as well as the territorial and social organization of the peoples. Appropriate analytical methodologies for this type of research are limited since there are strict requirements with reference to precision, sensitivity and detection limits, all characteristics that the activation analysis technique provides. The Chilean Nuclear Energy Commission, the University of Chile, the Smithsonian Institution and the International Atomic Energy Agency developed together a cooperative interregional project to promote interdisciplinary research, to resolve archaeological problems and to develop a new application for a nuclear analytical technique. Until this work was undertaken, no systematic studies of trace elements in archaeological ceramics had been done in Chile using the technique of Instrumental Neutron Activation Analysis (INAA). This analytical technique was used in this research to chemically characterize archaeological pieces with the sensitivity, precision and accuracy needed to be able to work with mathematical models that can or cannot establish relationships between the different samples. Protocols were defined first for preparing the pottery samples in order to generate representative samples that could be analyzed by INAA. The homogeneity in preparing the samples used was defined using a group of elements that could be determined by INAA with a precision under 2%. A group of 18 elements was selected and an analytical test procedure was planned that included the type of packaging for the irradiation, the irradiation times, decline and count, the standards to be used and the type of monitor for correcting the neutron flow. The methodology used

  6. A subdivision of the upper Witwatersrand system based on the statistical analysis of trace element data

    International Nuclear Information System (INIS)

    Rasmussen, S.E.

    1976-08-01

    Some 71 samples were collected from the Upper Witwatersrand System; from below the Jeppestown Shales to the Upper Kimberley Conglomerates. A total of 74 samples plus standards were analyzed in duplicate for 26 elements; a total of 4000 determinations. A multivariate segmentation technique was developed and applied to the data. All the main stratographic features were succesfully identified. Samples could be back classified with an accurucy of 75% to the 7 segments identified, but this was increased to over 80% for the 3 most significant segments

  7. Benefit-cost framework for analysis of trace element emissions from coal-fired power plants. [103 references

    Energy Technology Data Exchange (ETDEWEB)

    None

    1979-11-01

    The major conclusions of this report may be summarized in the following four points: (1) It is probable that atmospheric emissions of trace elements from Southwestern coal-fired power plants will not cause major problems over the next 20 years. But monitoring for trace element build-up (especially mercury, selenium, and arsenic) in the mountains of southern Colorado, Navajo Reservoir, and other local hot spots would be an important and desirable step. (2) It appears that damage from trace elements in disposed ash is more likely than damage from atmospheric trace element emissions. But whether damage from disposed ash will actually occur is highly uncertain. We recommend that additional research be conducted on the entire range of issues surrounding ash disposal. (3) In the area of legislation and regulation, there may be some need for review of regulations concerning trace element atmospheric emissions. Present regulation of ash disposal is very likely to need revision and extension. (4) Future research on the environmental problems of coal-fired power plants should place emphasis on atmospheric emissions of sulfur and nitrogen oxides; consequent problems of acid precipitation also need exploration. Environmental research on coal-fired power plants does not need to exclude other problems. But issues surrounding sulfur emissions, nitrogen emissions, sulfate transformations, and acid precipitation appear to merit major emphasis. Perhaps the most important aspect of the preceding list of conclusions is that more questions are raised than are answered. As work on the subject proceeded, it became apparent that an important task was to point future research in the right direction.

  8. Proper use of reference materials for trace element analysis and updates on their availability

    International Nuclear Information System (INIS)

    Snell, J.P.

    2009-01-01

    Full text: As different spectroscopic methods are used to certify reference materials (RMs) for element content, there is close interrelation between development of new methods and availability of new certified reference materials (CRMs). The Institute for Reference Materials and Measurements (IRMM) monitors changing scientific and regulatory interests, and adapts materials to current and predicted needs. This includes the development of CRMs with new matrices, or changing analytes and concentration levels for existing types of CRMs. Recent examples are CRMs to support the EC Directives on air quality and water, for nanoparticle characterization, and progressing international standards for biofuel measurements. User guidance including appropriate CRM selection, and use of uncertainties in comparing results will be highlighted. (author)

  9. Quantitative sampling and analysis of trace elements in atmospheric aerosols: impactor characterization and Synchrotron-XRF mass calibration

    Directory of Open Access Journals (Sweden)

    A. Richard

    2010-10-01

    Full Text Available Identification of trace elements in ambient air can add substantial information to pollution source apportionment studies, although they do not contribute significantly to emissions in terms of mass. A method for quantitative size and time-resolved trace element evaluation in ambient aerosols with a rotating drum impactor and synchrotron radiation based X-ray fluorescence is presented. The impactor collection efficiency curves and size segregation characteristics were investigated in an experiment with oil and salt particles. Cutoff diameters were determined through the ratio of size distributions measured with two particle sizers. Furthermore, an external calibration technique to empirically link fluorescence intensities to ambient concentrations was developed. Solutions of elemental standards were applied with an ink-jet printer on thin films and area concentrations were subsequently evaluated with external wet chemical methods. These customized and reusable reference standards enable quantification of different data sets analyzed under varying experimental conditions.

  10. Trace element distribution in the rat cerebellum

    International Nuclear Information System (INIS)

    Kwiatek, W.M.; Long, G.J.; Pounds, J.G.; Reuhl, K.R.; Hanson, A.L.; Jones, K.W.

    1989-10-01

    Spatial distributions and concentrations of trace elements (TE) in the brain are important because TE perform catalytic structural functions in enzymes which regulate brain function and development. We have investigated the distributions of TE in rat cerebellum. Structures were sectioned and analyzed by the Synchrotron Radiation Induced X-ray Emission (SRIXE) method using the NSLS X-26 white-light microprobe facility. Advantages important for TE analysis of biological specimens with x-ray microscopy include short time of measurement, high brightness and flux, good spatial resolution, multielemental detection, good sensitivity, and non-destructive irradiation. Trace elements were measured in thin rat brain sections of 20-micrometers thickness. The analyses were performed on sample volumes as small as 0.2 nl with Minimum Detectable Limits (MDL) of 50 ppb wet weight for Fe, 100 ppb wet weight for Cu, and Zn, and 1 ppM wet weight for Pb. The distribution of TE in the molecular cell layer, granule cell layer and fiber tract of rat cerebella was investigated. Both point analyses and two-dimensional semi-quantitative mapping of the TE distribution in a section were used

  11. Determination of Trace Elements in Thai Cereal

    International Nuclear Information System (INIS)

    Permnamtip, Vorapot; Busamongkol, Arporn; Laoharojanaphand, Sirinart; Chaiyasith, Suwan

    2007-08-01

    Full text: Trace elements were analyzed in Thai cereal, e.g. rice and bean, by using neutron activation analysis (NAA). The selected cereals are major food items for Thai population. The data obtained from this work will be useful for nutrition and safety consumption of Thai cereal. Trace elements verified include Al, As, Br, Ca, Cd, Cl, Cr, Cu, Fe, I, K, Mg, Mn, Mo, Se, Sn, V and Zn. It was found that Al, As, Br, Cl, Cu, Fe, Mn, Zn, Ca, K and Mg are presented in the range of 2.2 to 35.7, 0.15 to 0.21, 0.44 to 13.5, 55.6 to 640.3, 16.3 to 16.5, 158.9 to 161.1, 12.2 to 55.7, 8.2 to 58.1 (g/g (ppm) , 0.02 to 0.28, 0.09 to 1.99 and 0.03 to 0.26 %, respectively. For Cd, Cr, I, Mo, Se, Sn and V were not found in sample because the concentrations were lower than detection limit. Precision and accuracy were determined by analyzing standard reference materials: NIST 1568a, NIST 8704, ACSP DORM-1, NIES No.9 and NMIJ 7302 to a

  12. Application of multivariate analysis to investigate the trace element contamination in top soil of coal mining district in Jorong, South Kalimantan, Indonesia

    Science.gov (United States)

    Pujiwati, Arie; Nakamura, K.; Watanabe, N.; Komai, T.

    2018-02-01

    Multivariate analysis is applied to investigate geochemistry of several trace elements in top soils and their relation with the contamination source as the influence of coal mines in Jorong, South Kalimantan. Total concentration of Cd, V, Co, Ni, Cr, Zn, As, Pb, Sb, Cu and Ba was determined in 20 soil samples by the bulk analysis. Pearson correlation is applied to specify the linear correlation among the elements. Principal Component Analysis (PCA) and Cluster Analysis (CA) were applied to observe the classification of trace elements and contamination sources. The results suggest that contamination loading is contributed by Cr, Cu, Ni, Zn, As, and Pb. The elemental loading mostly affects the non-coal mining area, for instances the area near settlement and agricultural land use. Moreover, the contamination source is classified into the areas that are influenced by the coal mining activity, the agricultural types, and the river mixing zone. Multivariate analysis could elucidate the elemental loading and the contamination sources of trace elements in the vicinity of coal mine area.

  13. Neutron activation analysis of trace elements in a marine sediment reference material

    International Nuclear Information System (INIS)

    Esquivel, D.; Eguren, L.; Montoya, E.

    1993-01-01

    As part of the second intercomparison run of ARCAL-IV, it was analyzed the marine sediment, reference materials PACS-NR CC1 by INAA, in the RP-10 Reactor with a thermal flux of 7,8 x 10 13 n/cm 2 s. The results obtained (± 1σ,n=4) were: Co: 17,2±0,8 ppm; Cr:97,8±0,6 ppm; Fe: 46,0± 0,7 ppm; Na: 31,0±1,09/kg; Sb: 175±5 ppm; in good agreement with the certified values. The results in ppm (±18,n=4), for non certified elements were:Ba: 730±58; Ce: 25±3; Cs: 3,8±0,8; Eu: 1,00±0,03; Hf: 3,30±0,07; Lu:0,25±0,04; Rb: 44,0±0,9; Sc: 14,40±0,04; Sm: 3,4±0,5; Ta: 0,60±0,03; Tb: 0,5±0,05; Th: 3,80±0,02; U: 2,6±0,4; which are in good agreement with other three Latin American and one European INAA Laboratories. It was used the comparative method with AGV-1, GSP-1 and G-2 , USGS reference materials, as standards. (authors). 7 refs., 4 tabs

  14. A simple chemical method for the separation of phosphorus interfering the trace element determinations by neutron activation analysis in high doped silicon wafers

    International Nuclear Information System (INIS)

    Wagler, H.; Flachowsky, J.

    1986-01-01

    Neutron activation analysis is one of the most available method for the determination of trace elements, but in the case of P-doped silicon wafers the 32 P-activity interferes the gamma spectrometry. It is not possible to determine the trace elements without chemical manipulations. On the other hand, time consuming chemical separations should be avoided. Therefore, a simple and rapid P-separation method has to be developed, in which the following twelve trace elements should be taken into consideration: Ag, As, Au, Co, Cr, Cu, Fe, Mo, Na, Sb, W, and Zn. After acid oxidative dissolution of the activated sample, P is present as phosphate ion. The phosphate ion is removed by precipitation as BiPO 4 . (author)

  15. Multi trace element analysis of dry biological materials by neutron activation analysis including a chemical group separation

    International Nuclear Information System (INIS)

    Weers, C.A.

    1980-07-01

    Multi-element analysis of dry biological material by neutron activation analysis has to include radiochemical separation. The evaporation process is described in terms of the half-volume. The pretreatment of the samples and the development of the destruction-evaporation apparatus are described. The successive adsorption steps with active charcoal, Al 2 O 3 and coprecipitation with Fe(OH) 3 are described. Results obtained for standard reference materials are summarized. (G.T.H.)

  16. Metal and trace element sediment assessment from Salto Grande reservoir, Sao Paulo state, Brazil, by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Soares, Walace A.A.; Favaro, Deborah I.T.

    2011-01-01

    The Salto Grande Reservoir is used for electric generation, irrigation, fish farming, recreation and water supply for the region's cities. The reservoir belongs to the city of Americana, located in on the eastern region of Sao Paulo State, Brazil. It belongs to the Piracicaba River Hydrographic Basin, the second most important economic and populated region and one of the most polluted areas in the State. This basin is located in a highly industrialized and agricultural region. Due to urban, industrial and agricultural activities as well as sewage wastes the water and sediments of this reservoir and surroundings are extremely contaminated, mainly by metals, according to CETESB (Environmental Control Agency of the Sao Paulo State). In order to obtain better information about its sediment contamination the present study reports results of the concentration of some major (Ca, Fe, K and Na), trace (As, Ba, Br, Co, Cr, Cs, Hf, Rb, Sb, Se, Ta, Th, U, Zn and rare earth (Ce, Eu, La, Lu, Nd, Sc, Sm, Tb and Yb)) elements in sediments and Cd, Cr, Cu, Ni and Pb concentration in sediments and water from the Salto Grande Reservoir. Multielementar analysis was carried out by Instrumental Neutron Activation Analysis (INAA). Multielemental concentrations in the sediment samples were compared to NASC (North American Shale Composite) values. The concentration values for metals As, Cd, Cr, Cu, Pb, Ni and Zn were compared to the Canadian Council of Minister of the Environment (CCME) oriented values (TEL and PEL) and adopted by CETESB, (author)

  17. Analysis of five trace elements in medicinal plants used in ayurvedic medicine to control diabetes

    International Nuclear Information System (INIS)

    Hewamanna, R.; Anuraadhi, N.; Fernando, R.K.S.

    2004-12-01

    Analysis of Chromium, Vanadium, Iron, Copper and Zinc known to influence the glucose/ insulin system was carried out in 36 different Ayurvedic medicinal plant species used to control and treat diabetes in Sri Lanka using the Energy Dispersive X ray fuorescence technique. Chromium, which is an essential nutrient in carbohydrate and lipid metabolism, was measured in 7 plant species ranging from 13-82 ppm dry ash weight. Polarographic analysis showed that one fourth of the chromium was present in the trivalent state in all seven plant species namely Ficus banghalensis, Ficus racemosa, Musa pradisiaca, Coccinea grandis, Benincasa hispida, Pongamia pinnata and Acacia nilotica. The importance of the other metals in the control of diabetes is also briefly discussed

  18. Isotopic and trace-element analysis of the continental carbonates in the Ballik area, Denizli, Turkey

    OpenAIRE

    Claes, Hannes; Soete, Jeroen; Swennen, Rudy; Foubert, Anneleen; Özkul, Mehmet; Baykara, Mehmet Oruç

    2012-01-01

    The Ballık continental carbonates were geochemically characterized using Inductively Coupled Plasma Optical Emission Spectroscopy (ICP-OES) and a δ18O, δ13C and strontium stable isotopic analysis. The geochemical delineation of the lithofacies, characterizing certain depositional environments, can be used in a chemo-stratigraphic approach to correlate the geobodies. Based on the stable isotopic composition the fluido characteristics and possible source rocks are deduced. The co...

  19. The analysis of a trace amount of elements in crude drugs

    International Nuclear Information System (INIS)

    Wakayama, I.; Akagawa, J.; Yase, Y.; Yoshida, S.; Sasajima, Kazuhisa

    2001-01-01

    The concentrations and the pharmacological actions of iron and zinc in nearly 30 kinds of crude drugs of Chinese medicine are studied using the neutron activation analysis, quantitatively. The quantitative analytical results are also compared with the semi-quantitative analytical results of iron and zinc obtained by particle induced X-ray emission spectroscopy. The crude drugs with higher iron concentration were almost drugs for the mentality. The crude drugs with highest zinc concentration were also the drugs for the mentality. (H. Katsuta)

  20. Trace elements in California aerosols. Part I. Instrumental neutron activation analysis techniques

    International Nuclear Information System (INIS)

    Ragaini, R.C.; Ralston, H.R.; Garvis, D.; Kaifer, R.

    1975-01-01

    Instrumental Neutron Activation Analysis (INAA) done at LLL played a key role in the 1972--1974 California Aerosol Characterization Experiment (ACHEX), a major experiment in the chemistry of aerosols in urban and non-urban sites of California sponsored by the State of California Air Resources Board. The main purpose of INAA was to measure the particle size distributions and diurnal patterns of key chemical constituents in aerosols collected in California. These data were used to satisfy some of the key objectives of ACHEX, including aerosol characterization and evaluation of the origins and evolutions of aerosols. Secondary uses of INAA were the validations of the Lundgren rotating drum cascade impactors used in the ACHEX, and validations of other analytical techniques used in the chemical analyses. As a result of these studies, it was concluded that techniques using INAA were useful operational methods for chemical analysis of aerosols collected over two-hour periods in urban air with an active monitoring program. (U.S.)

  1. Biomonitoring of air pollution in Jamaica through trace-element analysis of epiphytic plants using nuclear and related analytical techniques

    International Nuclear Information System (INIS)

    Vutchkov, M.; Lalor, G.C.; Preston, J.

    1999-01-01

    Air quality has been monitored at selected areas in Jamaica using high volume samplers. The results obtained, showed elevated levels of aluminium in bauxitic areas and very high lead concentrations in urban areas, from 5 to 35 times greater than in rural areas. The lower throughput of the conventional air particulate samplers however, restricts the air quality and health assessment on a nation-wide scale. Biomonitoring offers a cost-effective alternative to air-quality assessment if appropriate indicator species are chosen. The epiphytic lower plants such as lichens and mosses have been used as indicators of regional air quality in several European countries and USA. However, there is not enough studies on lichens and mosses in tropical countries, probably due to the lower occurrence of these species, which cover only 8% of the world's land surface. In Jamaica the epiphytic higher plants, represented by the genus Tillandsia are widely distributed, which make them along with the lichens and mosses potential site-specific bioindicators of air quality. The IAEA Co-ordinated Research Project entitled 'Biomonitoring of Air Pollution in Jamaica Through Trace-Element Analysis of Epiphytic Plants Using Nuclear And Related Analytical Techniques' will address these needs of the country. The primary purpose of the present study was to develop specific bioindicators of atmospheric air pollution in Jamaica, which will provide baseline information for health hazards assessment

  2. Metal and trace element sediment assessment from Ribeira do Iguape river, Sao Paulo state, Brazil, by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Castro, Francisco J.V. de; Quinaglia, Gilson A.; Favaro, Deborah I.T.; Franklin, Robson L.; Ferreira, Francisco J.

    2011-01-01

    The watershed region of the Ribeira do Iguape River and the estuarine complex of the Paranagua-Iguape- Cananeia and the various river basins located between this region and the Atlantic Ocean, is known as the Ribeira Valley. The Ribeira do Iguape River runs a total length of approximately 470 km, being the main source of fresh water in the Estuarine Complex of the Iguape-Cananeia-Paranagua (Lagamar). The Ribeira do Iguape River is the last major river in the State of Sao Paulo that has not been altered by dams. During virtually the entire 20th century, the region of the Ribeira Valley was the scene of constant environmental degradation resulting from the intense exploration and refining of lead, zinc and silver ores that were processed in the mines of the region, in a rudimentary way and without any control over environmental impacts. Since 1996, all such activities ceased, however, leaving behind a huge amount of environmental liabilities. This study aims to investigate the presence and concentration levels of metals and semi-metals arsenic (As), cadmium (Cd) and lead (Pb) in the sediment and water of aquatic systems of Ribeira do Iguape River and its tributaries, for an environmental assessment and monitoring of the region. The determination of these elements was carried out by GF AAS technique for water samples and ICP OES for the sediment samples. This study also assessed the occurrence of some major (Ca, Fe, K and Na), trace (As, Ba, Br, Co, Cs, Hf, Rb, Sb, Sc, Se, Ta, Th, U, Zn) and rare earth elements (La, Ce, Eu, Nd, Sm, Lu, Tb and Yb) by Neutron Activation Analysis (NAA). Validation of both methodologies, according to precision and accuracy, was done by reference material analyses. The results obtained for As, Cd and Pb were compared to the Canadian Environmental oriented values (TEL and PEL). The results obtained for multielemental analyses in the sediment samples were compared to UCC values (Upper Continental Crust). (author)

  3. Trace element composition of hair in the Italian population

    International Nuclear Information System (INIS)

    Clemente, G.F.; Cigna Rossi, L.

    1979-01-01

    The content of the trace elements Ag, Co, Cr, Cs, Fe, Hg, Ni, Rb, Sb, Sc, Se and Zn has been evaluated in hair samples collected from five different groups of subjects in Italy. All the measurements were performed by means of non-destructive neutron activation analysis of the hair samples that were carefully washed before analysis. In most of the samples the Cs, Rb and Sc content was below the detection limit of the analytical method. Each population group was formed of about five individuals of each sex, selected to be representative of the adult population living in a well-defined community. The five groups were chosen from distinct regions with different socio-economical living habits in order to detect the variability, if any, of the trace element burden among the Italian population. The trace element hair concentration of each subject was correlated with the trace element blood concentration and daily urinary excretion in order to differentiate the trace element content due to exogenous deposition on hair from that due to endogenous absorption routes. The results obtained show that the variability of the hair content among the various groups is strongly linked to local environmental factors. The histograms of the individual values of the hair concentration are given for all trace elements measured, together with a statistical analysis of all data. (author)

  4. Advantages of the iridium permanent modifier in fast programs applied to trace-element analysis of plant samples by electrothermal atomic absorption spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Vassileva, E.; Baeten, H.; Hoenig, M. [Centre for Veterinary and Agrochemical Research (CERVA), Tervuren (Belgium)

    2001-03-01

    The application of a fast program combined with the advantages of the iridium permanent modifier is proposed for trace element analysis of plant samples by electrothermal atomic absorption spectrometry (ETAAS). For two volatile elements (Cd, Pb) and two mid-refractory elements (Cr, Ni) it was demonstrated that coating of the platform or of the tube atomization area with Ir is an efficient means of improving the accuracy and precision of results. A detailed study of interference from individual main matrix components and from composite plant matrices has confirmed the usefulness of the whole approach. The validity of the method has been confirmed by analysis of eight reference plant materials. (orig.)

  5. Toxic trace elements in Chilean seafoods

    International Nuclear Information System (INIS)

    De Gregori, I.; Delgado, D.; Pinochet, H.; Gras, N.; Thieck, M.; Munoz, L.; Bruhn, C.; Navarrete, G.

    1992-01-01

    Chile is a well known producer and exporter of shell fish. These seafoods, like other specimens of marine origin, are susceptible to environmental and other contaminations like trace elements, including toxicants. Therefore adequate analytical quality assurance is mandatory before accepting analytical results. In this context, use of at least 2 independent methods of determination and validation with certified reference materials (CRM) provides acceptable criteria for judging the reliability of the data. This paper describes sample treatments and analytical procedures for Cd, Cu and Hg determinations in mollusc samples. Three independent analytical techniques, namely differential pulse anodic stripping voltammetry, neutron activation analysis and atomic absorption spectrometry, were used. CRM standards of the IAEA, NIST and BCR were analyzed to evaluate quality assurance. Following the quality control phase, the concentrations of cadmium, copper, and mercury in fresh and canned mollusc samples Tagelus dombeii and Semelle solida (Navajuelas and Almejas chilenas respectively) from different locations were determined. (author). 32 refs.; 4 figs.; 7 tabs

  6. Use of Instrumental Neutron Activation Analysis for Determination of Some Trace Elements of Biological Importance in Different Jute(Corchorus Capsularis) Seed Samples

    International Nuclear Information System (INIS)

    Metwally, E.; Abd-El-Khalik, H.; El-Sweify, F.H.; El-Sweify, A.H.H.

    2004-01-01

    Instrumental neutron activation analysis technique was used to determine some trace elements in seeds of jute (corchorus capsularis). The seed samples were obtained from Agricultural Research Center (ARC), Giza, (EG). The analyzed seed samples were produced from cultivation of three different strains, namely: St. DC 1105, st. JRC 7447 and St. PADMA. These strains were imported from Bangladesh. The jute plant was cultivated in sandy soil in Ismailaya research station farm at may on two seasons 1999 and 2000. The plant was irrigated with water from Ismailaya canal. The study was carried out to compare the influence of applying different kinds of fertilizers of different rates, i.e. mineral fertilizer and biofertilizer, on the uptake of some biologically important trace elements and to determine their concentration in the analyzed jute seed samples. These elements were; Co,Cr,Fe,Zn and others eight elements were analyzed quantitatively

  7. Nutritional values of trace elements in dried desserts

    International Nuclear Information System (INIS)

    Kyritsis, A.; Kanias, G.D.; Tzia, C.

    1997-01-01

    Desserts are the most aromatic and delicious parts of meals, and also a source of nutrient trace elements for the human body. In this work, instrumental neutron activation analysis has been applied to determine the trace elements antimony, chromium, cobalt, iron, manganese, potassium, rubidium, scandium, sodium and zinc in creme caramel, ice-creams, jellies and mousse dried desserts from the Greek market. According to our results, their classification as nutrient trace element sources for the human body is: mousse>ice-cream> creme caramel> jelly. Among the different studied flavours, chocolate and its derivatives are the richest in nutrient trace elements. Moreover, the consumption of one portion of a chocolate mousse dessert can offer to the human body about 60% of the daily required chromium, 40% of the daily required iron, 10% of the daily required manganese and potassium and 4% of the daily required sodium. (author)

  8. Trace elements distribution in environmental compartments

    Energy Technology Data Exchange (ETDEWEB)

    Queiroz, Juliana C. de; Peres, Sueli da Silva; Godoy, Maria Luiza D.P., E-mail: suelip@ird.gov.br [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2017-11-01

    Trace elements term defines the presence of low concentrations metals at environment. Some of them are considered biologically essential, as Co, Cu and Mn. Others can cause detriment to environment and human health, as Pb, Cd, Hg, As, Ti and U. A large number of them have radioactive isotopes, implying the evaluation of risks for human health should be done considering the precepts of environmental radiological protection. The ecosystem pollution with trace elements generates changes at the geochemistry cycle of these elements and in environmental quality. Soils have single characteristics when compared with another components of biosphere (air, water and biota), cause they introduce themselves not only as a drain towards contaminants, but also as natural buffer that control the transport of chemical elements and other substances for atmosphere, hydrosphere and biota. The main purpose of environmental monitoring program is to evaluate the levels of contaminants in the various compartments of the environment: natural or anthropogenic, and to assess the contribution of a potential contaminant source on the environment. Elemental Composition for the collected samples was determined by inductively coupled plasma mass spectroscopy. The main objective of this work was to evaluate the map baseline of concentration of interest trace elements in environmental samples of water, sediment and soil from Environmental Monitoring Program of Instituto de Radioprotecao e Dosimetria (IRD). The samples were analyzed using an inductively coupled plasma mass spectrometer (ICP-MS) at IRD. >From the knowledge of trace elements concentrations, could be evaluated the environmental quality parameters at the studied ecosystems. The data allowed evaluating some relevant aspects of the study of trace elements in soil and aquatic systems, with emphasis at the distribution, concentration and identification of main anthropic sources of contamination at environment. (author)

  9. Trace elements distribution in environmental compartments

    International Nuclear Information System (INIS)

    Queiroz, Juliana C. de; Peres, Sueli da Silva; Godoy, Maria Luiza D.P.

    2017-01-01

    Trace elements term defines the presence of low concentrations metals at environment. Some of them are considered biologically essential, as Co, Cu and Mn. Others can cause detriment to environment and human health, as Pb, Cd, Hg, As, Ti and U. A large number of them have radioactive isotopes, implying the evaluation of risks for human health should be done considering the precepts of environmental radiological protection. The ecosystem pollution with trace elements generates changes at the geochemistry cycle of these elements and in environmental quality. Soils have single characteristics when compared with another components of biosphere (air, water and biota), cause they introduce themselves not only as a drain towards contaminants, but also as natural buffer that control the transport of chemical elements and other substances for atmosphere, hydrosphere and biota. The main purpose of environmental monitoring program is to evaluate the levels of contaminants in the various compartments of the environment: natural or anthropogenic, and to assess the contribution of a potential contaminant source on the environment. Elemental Composition for the collected samples was determined by inductively coupled plasma mass spectroscopy. The main objective of this work was to evaluate the map baseline of concentration of interest trace elements in environmental samples of water, sediment and soil from Environmental Monitoring Program of Instituto de Radioprotecao e Dosimetria (IRD). The samples were analyzed using an inductively coupled plasma mass spectrometer (ICP-MS) at IRD. >From the knowledge of trace elements concentrations, could be evaluated the environmental quality parameters at the studied ecosystems. The data allowed evaluating some relevant aspects of the study of trace elements in soil and aquatic systems, with emphasis at the distribution, concentration and identification of main anthropic sources of contamination at environment. (author)

  10. Comparative evaluation of trace elements in blood

    International Nuclear Information System (INIS)

    Goeij, J.J.M. de; Tjioe, P.S.; Pries, C.; Zwiers, J.H.L.

    1976-01-01

    The Interuniversitair Reactor Instituut and the Centraal Laboratorium TNO have carried out a common investigation on neutron-activation-analytical procedures for the determination of trace elements in blood. A comparative evaluation of five methods, destructive as well as non-destructive, is given. The sensitivity and reproducibility of the procedures are discussed. By combining some of the methods it is possible, starting with 1 ml blood, to give quantitative information on 14 important trace elements: antimony, arsenic, bromine, cadmium, cobalt, gold, copper, mercury, molybdenum, nickel, rubidium, selenium, iron and zinc. The methods have also been applied to sodium, chromium and potassium

  11. A comparative study of minor and trace elements in human, animal and commercial milk samples by neutron activation analysis

    International Nuclear Information System (INIS)

    Garg, A.N.; Weginwar, R.G.; Chutke, N.L.

    1993-01-01

    Human, animal (cow, buffalo and goat) and commercial milk powders (for infants and adults) have been analyzed for 5 minor (Na, K, Mg, Cl and P) and 13 trace elements (Cr, Mn, Fe, Co, Cu, Zn, Cd, Hg, As, Se, Sb, Cs and Br) by instrumental and radiochemical neutron activation. Milk standards NIST SRM 1549 and IAEA A-11 along with diet standards RM 8431a and IAEA H-9 were also analyzed for quality assurance. The method involves thermal neutron irradiation for 10 m, 1 h, 6 h and 1 week in a reactor followed by high resolution γ-spectrometry. Concentrations of Fe, Co, Zn, Sb and Se were also determined by radiochemical solvent extraction. Mean concentrations of Na, K, Mg, P, Cl, Fe, Mn and Cu in human milk (colostrum) are comparable with that of a WHO/IAEA study. It has, however, lower contents of toxic trace elements (Cr, Cd, Hg, Br, Se, Sb and As) compared to breast tissue from the same area. Cow milk is richer in Na, K, Cl, Mn and Se but it has comparable amounts of Mg, Zn, Br, Fe and Sb with respect to breast milk. Significant differences have been observed for elemental concentrations of Na, K, P and Fe in commercial formula milk powders for infants and adults. Infant's milk powders contain all the nutrient elements in balanced amounts required for the higher growth rate of a child. (author) 41 refs.; 2 figs.; 3 tabs

  12. Newer trace elements measured by RNAA and AAS

    International Nuclear Information System (INIS)

    Gharib, A.G.

    2004-01-01

    Very recently, quite attention has been made on a few more trace elements in foodstuff as essential for animal and human health in certain ranges of concentration or intake. These traces are: aluminum, nickel, vanadium and tin. Al and Ni have been measured by atomic absorption spectroscopy (AAS), and the two latter ones measured by radiochemical neutron activation analysis (RNAA) in few references laboratories. Here, scandium was also analysed by instrumental neutron activation analysis (INAA). These measurements were made for the most of the Iranian diets and other participant countries' diets under the framework of a co-ordinated research project (CRP) of the IAEA during the period 1986-1994, but practically it took more years. Here in this work the daily dietary intakes of above mentioned trace elements are given and discussed while the results of 20 other nutritionally important trace elements appeared somewhere else. (author)

  13. A study on human hair element content as monitor for trace elements pollution in Eg

    International Nuclear Information System (INIS)

    Tadros, N.; Metwally, E.

    2004-01-01

    Trace element content in human is a suitable indicator of exposure to trace element pollutants. Concentration levels of 12 trace elements in human head hair samples collected from more than 23 individuals have been determined. The collected hair samples were classified into four groups collected from workers at nuclear research center and others far away from the center. Neutron activation analysis technique was used in the preset study. The data reported for trace elements content in different hair samples were discussed. Significant differences were observed for several elements levels. comparative studies demonstrated that the concentration of some elements in hair of exposed workers, are greater than those corresponding to non exposed workers. Also, there was no clear significant correlation between the elements content of different hair samples and the age of the donors

  14. Trace elements in glucometabolic disorders: an update

    Directory of Open Access Journals (Sweden)

    Wiernsperger Nicolas

    2010-12-01

    Full Text Available Abstract Many trace elements, among which metals, are indispensable for proper functioning of a myriad of biochemical reactions, more particularly as enzyme cofactors. This is particularly true for the vast set of processes involved in regulation of glucose homeostasis, being it in glucose metabolism itself or in hormonal control, especially insulin. The role and importance of trace elements such as chromium, zinc, selenium, lithium and vanadium are much less evident and subjected to chronic debate. This review updates our actual knowledge concerning these five trace elements. A careful survey of the literature shows that while theoretical postulates from some key roles of these elements had led to real hopes for therapy of insulin resistance and diabetes, the limited experience based on available data indicates that beneficial effects and use of most of them are subjected to caution, given the narrow window between safe and unsafe doses. Clear therapeutic benefit in these pathologies is presently doubtful but some data indicate that these metals may have a clinical interest in patients presenting deficiencies in individual metal levels. The same holds true for an association of some trace elements such as chromium or zinc with oral antidiabetics. However, this area is essentially unexplored in adequate clinical trials, which are worth being performed.

  15. The distribution of trace elements in normal human liver determined by semi-automated radiochemical neutron activation analysis

    International Nuclear Information System (INIS)

    Lievens, P.; Cornelis, R.; Hoste, J.; Versieck, J.

    1977-01-01

    The eight segments of five normal human livers are analysed for 25 trace elements by radiochemical NAA. This consists of an automated wet destruction of the samples and two distillations, followed by ion exchange procedures. Ru is used as triplecomparator for the standardization. Short-lived and matrixisotopes are standardized by the Bowen's kale powder. The results reveal that the coefficient of variation within the liver is smaller than 10% for the elements Cd, Cl, Cs, Cu, Fe, K, Mg, Mn, Rb, Se and Zn. The highest range observed for the elements As, Br, Co, Cr, Hg, La, Mo, Na and Sb within a liver is smaller than the range observed between the five livers. (T.G.)

  16. Analysis of trace elements in power plant and industrial incinerator fly ashes by instrumental neutron activation analysis (INAA)

    International Nuclear Information System (INIS)

    Al-Areqi, Wadeeah M.; Amran Abdul Majid; Sukiman Sarmani

    2008-01-01

    An elemental analysis of fly ash samples from Selangor and Perak coal-fired power plants and an industrial incinerator from Negeri Sembilan were carried out using instrumental neutron activation analysis (INAA). All samples were irradiated at the Malaysian Nuclear Agency laboratory PUSPATI Reactor for 6 hours and later counted at the Nuclear Science Program, UKM using an HPGe detector with a relative efficiency of 10% and resolution of 1.8 KeV (FWHM) at 1.33 MeV. International Atomic Energy Agency (IAEA) coal fly ash 1633a reference material (SRM) was used as a standard for quantitative analysis. A total of 11 elements (i.e. As, Ba, Ca, Ce, Cr, Co, Fe, Hf, Sc, Th and U) were determined in all three types of fly ashes. The concentration range of environmentally concern elements, As and Cr in the Selangor coal-fired power plant samples are 11.17 - 23.24 and 160.28 - 867.97 μg.g -1 respectively. The concentration range of radioactive elements U and Th are 4.79 - 10.29 and 14.6 - 61.29 μg.g -1 respectively, and the concentration range of Co, Hf, Fe, Sc, Ba, Ce, Ca are 11.88-83.61, 3.24 - 10.48, 30338 - 53885, 16.62 - 28.48, 178.97 - 8491, 127.41 - 217.2 and 10447 -20647 μg.g -1 respectively. The concentration range of As, Cr, U, Th in the Perak samples were found to be 22.16 - 48.38, 44.37 - 74.78, 4.18 - 6.85, 8.71 - 11.43 μg.g -1 respectively, whereas the concentration range of Co, Fe, Sc, Ba, Ce and Ca are 23.21 -29.66, 54621 - 71099, 30.9 - 31.77, 100.34 - 116.61 and 11533 -16423 μg.g -1 respectively. Differences exist in the elemental concentrations of both power plant fly ash samples due to the different feed coal and combustion temperature used. The concentration of Cr, Th and Ce in the Selangor fly ash samples was generally higher compared to the samples obtained from the Perak power plant. This study also shows that only As and Ca were detected in the Negeri Sembilan samples with the concentration ranging from 36.66 - 98.67 and 31709.10 - 45606 μg.g -1

  17. Determination of natural radioactive elements in building materials by gamma spectroscopy, trace dosimetry and neutron activation analysis

    International Nuclear Information System (INIS)

    Perez, G.; Desdin, L.F.; Hernandez, A.T.; Gonzalez, D.; Labrada, A.; Tenreiro, J.J.; Capote, G.; Perelyguin, V.P.; Herrera, H.; Tellez, E.

    1993-01-01

    Five types of Cuban concretes and their main components (minerals aggregates and cement) were investigated in order to analyze the content of uranium, thorium, radium, potassium and radon 220,222, using gamma spectroscopy, trace dosimetry and neutron activation analysis. The comparative evaluation of different concretes, aggregates and two types of cements according to natural radioactivity is shown

  18. Determination of the minor and trace elements in Biriniwa's tin pyrite and ornamental lead/zinc ore using neutron activation analysis

    OpenAIRE

    A.O. Adebayo; H.O. Ogunsuyi; M.O.A. Oladipo; O.O. Ajayi

    2002-01-01

    Preliminary results of analysis of two common decorative/ornamental minerals analysed for minor and trace elements with the neutron activation analysis technique are discussed. The samples of interest were the Biriniwa tin pyrite, which the local indigenous used to paint their huts and the ornamental lead which women use to adorn their eyelashes nation-wide. These samples were irradiated along the certified reference sample, CANMET-BLI, with thermal neutron at the Julich Reactor Centre, Julic...

  19. Biomonitoring of coastal areas in Tunisia: Stable isotope and trace element analysis in the Yellow-legged Gull

    International Nuclear Information System (INIS)

    Abdennadher, Aida; Ramirez, Francisco; Romdhane, Mohamed Salah; Ruiz, Xavier; Jover, Lluis; Sanpera, Carolina

    2010-01-01

    We used Yellow-legged Gull (YLG) chicks to monitor trace elements in Tunisian areas subject to different pollution stresses: urban contamination (Chikly), industrial pollution (Thyna) and an unpolluted area (Kneis). We measured trace element concentrations (Hg, Se and Pb) in chick feathers. We also assessed their feeding ecology by analyzing both regurgitates and stable isotopes (SIA) in chick feathers and in their prey, to determine the main entry route of pollutants. SIA revealed that YLG feed mainly on aquatic resources from the Lake of Tunis (Chikly colony) and the Gulf of Gabes (Thyna and Kneis colonies). Moreover, the enriched δ 15 N found in feathers from Chikly are attributed to the eutrophication of the Lake of Tunis. Hg and Se were higher in Kneis and Thyna colonies, in agreement with the higher consumption of marine resources and the greater availability of these elements resulting from the impact of the industrial activity in the area. Pb concentrations were higher in Chikly, related to the heavier traffic around the Lake of Tunis and the use of leaded gasoline.

  20. Trace Elements in Human Nutrition and Health

    African Journals Online (AJOL)

    Trace Elements in Human Nutrition and Health, a report of a. World Heatth Organisation Expert Committee, contains material contributed by numerous experts consulted in different specialised fields, together with the conClusions reached and recommendations made by the Expert. Consultation. The nineteen nutritionally ...

  1. Changes in Trace Elements In Kwashiorkor

    African Journals Online (AJOL)

    1974-03-13

    Mar 13, 1974 ... Evidence exists that trace elements are in imbalance in kwashiorkor. A decrease in the plasma zinc and copper'· and liver copper'l has been found. The copper content of hair determined in kwashiorkor patients gave contro- versial results.""" Elood selenium levels decreased, and the in vivo red cell uptake ...

  2. Environmental Risk Limits for Nine Trace Elements

    NARCIS (Netherlands)

    Vlaardingen PLA van; Posthumus R; Posthuma-Doodeman CJAM; SEC

    2005-01-01

    In this report, we present an update of environmental risk limits (ERLs), based on the literature, for nine trace elements, namely, beryllium (Be), vanadium (V), cobalt (Co), selenium (Se), molybdenum (Mo), tin (Sn), antimony (Sb), barium (Ba) and thallium (Tl). The updated ERLs, established for

  3. Incorporation of trace elements into hair structure

    International Nuclear Information System (INIS)

    Limic, N.; Valkovic, V.

    1985-01-01

    Examining blood and urine provides an immense insight into human diseases. It is natural to hope that the hair studies will be added routinely to the examinations. Human head hair is a recording filament which can reflect metabolic changes of many elements over a long period of time. The idea of hair analysis is very inviting, because hair is easily samples, shipped and analyzed. In this paper the authors propose a method for the determination of some diffusion parameters from experimental data on the distribution of trace element concentrations in hair and then a method for the determination of the radial diffusion constants of Se, Zn and Pb. The authors' model of hair structure with respect to diffusion is based on the supposition of cross-sectional homogeneity as well as the longitudinal homogeneity of hair. This supposition implies nonisotropic diffusion in hair which is described by two diffusion constants. Diffusion constants can be determined by experiment on wetting hair in solvents or by measurements of natural contamination of hair in air. The first type of experiments can be arranged in various ways to separate radial diffusion from the longitudinal one and, consequently, to determine two diffusion constants from various sets of experiments. The authors' aim is to consider only radial diffusion in hair and to determine the radial diffusion constants of Se, Zn and Pb

  4. Trace element analysis by PIXE in liver samples from dogs with chronic active hepatitis and liver cirrhosis

    Science.gov (United States)

    Andersson, Marianne; Ekholm, Ann-Kristin; Sevelius, Ewa

    1990-04-01

    Trace element levels of liver samples obtained from necropsied dogs suffering from hepatitis and/or liver cirrhosis were determined by PIXE. Two different techniques for preparation of the samples were compared: the pellet press method and wet digestion. Both methods gave similar results, but the pellet press method was chosen for the subsequent routine analyses because of its simplicity due to few preparation steps and little risk of contamination. Preliminary results indicate elevated levels of Cu in chronic hepatitis and cirrhosis. In hereditary copper-induced hepatitis (Bedlington hepatitis) Fe and Br levels were increased as well.

  5. Determination and statistical analysis of trace element and active constituent concentrations in the medicinal plant Eucalyptus camaldulensis Dehnh (E. rostratus Schlecht)

    International Nuclear Information System (INIS)

    Kanias, G.D.; Kilikoglou, V.; Tsitsa, E.; Loukis, A.

    1993-01-01

    In the leaves of the medicinal plant Eucalyptus camaldulensis Dehnh (E. rostratus Schlecht) collected from different sampling areas of Greece the trace elements antimony, cesium, chromium, cobalt, iron, europium, rubidium scandium, strontium, thorium and zinc were determined by Instrumental Neutron Activation Analysis. In the same samples, the essential oil was determined by steam distillation and the percent relative composition of the essential oil in 1,8-cineole, p-cymene, α-pinene by gas liquid chromatography. Also the refractive index of the essential oil was determined by a refractometer. Statistical analysis included the calculation of the correlation coefficient. Multiple correlation and cluster analysis was applied to all analytical data. The results showed that the trace elements iron, chromium, cobalt and zinc are correlated with the variation of the concentration of essential oil in the examined plant. These four elements along with rubidium and essential oil content could be used for the separation of the samples into groups related to the sampling areas. Statistically significant correlation between active constituents and some trace elements and a linear negative correlation between 1,8-cineole and refractive index were found. (author) 13 refs.; 2 figs.; 2 tabs

  6. The study of the trace element in organisms by neutron analysis. I. Multielement instrumental neutron activation analysis of cannabis

    International Nuclear Information System (INIS)

    Shinogi, M.; Murai, Y.; Mori, I.; Takeuchi, T.

    1977-05-01

    Examinations were made on optimal experimental conditions for instrumental determination of various elements in cannabis by neutron activation analysis, without any radiochemical separation, and the following conditions were found to be useful. Irradiation samples to be used are about 300 mg of the leaves or stem bark, and about 100 mg of the root. For soil sample, about 50 mg is used for the determination of short half-life nuclides and about 300 mg for long half-life nuclides. For short half-life nuclides, the samples are irradiated for 1 min, activity is measured for 200 sec after a decay of 3 min, and for 400 sec after a decay of 10 min. For long half-life nuclides, the samples are irradiated for 60 min and the activities are measured for 4 K sec after 1 week and for 10 K sec after 1 month. Use of supersonic waves is also convenient for cleansing of the samples. Thirty-five kinds of interesting elements were determined by this method from cannabis cultivated in Maizuru area. (Author)

  7. Instrumental neutron activation analysis of site-dependent uptake and distribution of trace elements in the saltmarsh plant Aster tripolium from marsh fields in the Schelde estuary, Netherlands

    International Nuclear Information System (INIS)

    Rossbach, M.

    1986-07-01

    As part of an environmental chemical investigation the uptake of heavy metals by a saltmarsh plant Aster tripolium from two differently polluted salt marsh sites of the North Sea between 20 to 30 trace elements were determined in soil and plant organs. A sensitive gamma ray counting system was installed and tested for instrumental activation analyses (INAA). Installations to improve sensitivity as well as conditions necessary for reliable trace element analysis with the aid of Anticompton spectrometers (ACS) are described. The accuracy and reproducibility of the method was determined by the analysis of reference- and control materials of the german environmental specimen bank. In order to characterise the state of pollution of the salt marsh soils pollution-factors for single elements as well as interelemental correlations were evaluated. In addition, uptake and translocation factors of the biological samples were calculated. The many highly significant correlations between elements within the plant organs indicated that uptake appears to be physiologicaly controlled and not dependent on soil concentration. In order to detect further consequences of differing pollution influences within these plants biochemical separation techniques were applied and trace element levels in selected extracts were determined. For the specification of heavy metals gelpermeation chromatography of ethanolic extracts proved to be the most promising method. Furthermore, propositions for the use of trace elements as a fingerprint for pollution status and characterisation of species for referenz- and specimenbank materials have been developed. Aster tripolium as a cadmium accumulating plant can probably be used as an indicator in the monitoring of cadmium polluted salt marsh areas. (orig.) [de

  8. Determination of the levels of trace elements in ten years old children from Antofagasta city, Chile by neutron activation analysis

    International Nuclear Information System (INIS)

    Gras, N.; Munoz, A.L.; Jamett J, A.; Pena C, L.; Santander M, M.

    1988-01-01

    The levels of trace elements in scalp hair of ten years old children of Antofagasta city were determined. For this study, the city was divided in convenient areas. Comparisons between levels of concentrations considering residential areas, sex, values obtained for children of Santiago, and the ranges given in the literature were established. Fifty samples of hair were analyzed by instrumental neutron activation analisis. The elements selected were: As, Br, Co, Cr, Cu, Fe, Hg, K, Na. Sb, and Zn. The effectiveness of wash procedure before irradiation was studied. Ten samples were taken with sufficient amount of hair and each was divided into two, only one of them was washed and both were analyzed. The levels of concentrations were compared. (author)

  9. TRACE ELEMENTS IN FRUIT AND VEGETABLE

    Directory of Open Access Journals (Sweden)

    Stefania Papa

    2009-12-01

    Full Text Available The concentration of six different trace metals [vanadium (V, nickel (Ni, chromium (Cr,  lead (Pb, copper (Cu and cadmium (Cd] were determined in various fruit and vegetables [peach (Prunus persica L., plum (Prunus domestica L., tomato (Solanum lycopersicum L., courgette or marrow (Cucurbita pepo L. and lettuce (Lactuca sativa L.] provided by diverse farms. Metal distribution was also separately evaluated, in skin and pulp, where it was possible. Their contributions to human daily intake of trace metals were investigated. Atomic absorption spectrometry was used to determine the concentrations of these metals in the fruit and vegetables. All traces of elements tested in peaches and tomatoes were higher in the skin than in the pulp except for Cd in the peaches; all traces of elements tested in plums and marrows were higher in the pulp than in the skin. The concentrations of Pb and Cd in lettuce were 1.3 and 2.7 times above the permissible levels, respectively. It is concluded that the regular monitoring of food trace metals is very important to prevent diseases that depend on their excessive accumulation in the human food chain.

  10. Dietary reconstruction from trace element analysis and dental microwear in an Early Medieval population from Gán (Galanta district, Slovakia).

    Science.gov (United States)

    Bodoriková, Silvia; Tibenská, Kristína Domonkosová; Katina, Stanislav; Uhrová, Petra; Dörnhöferová, Michaela; Takács, Michal; Urminský, Jozef

    2013-01-01

    The aim of the study was to determine the diet of an historical human population using the trace elements in dental tissues and dental buccal microwear. Although 38 individuals had been buried in the cemetery, preservation of the remains did not allow analysis of all of them. A total of 13 individuals were analysed, of which the samples for trace-element analysis consisted of 12 permanent premolars from 12 individuals. Buccal microwear was studied in a sample of nine teeth from nine individuals. Both trace-element and microwear analyses were performed on eight individuals. All analyzed teeth were intact, with fully developed roots, without dental calculus and macro-abrasion. Concentrations of Sr, Zn, and Ca, and their ratios, were used to determine the relative proportions of plant and animal protein in the diet. Samples were analyzed using optical emission spectrometry with inductively coupled plasma. The values of the Sr and Zn concentrations indicate that a diet of the investigated population was of a mixed character with approximately the same proportion of plants and meat in their food. Buccal microwear was studied in molds ofbuccal surfaces and observed at 100x magnification with a scanning electron microscope (SEM). Length and orientation of striations were determined with the SigmaScan Pro 5.0 image analysis program. The results obtained from microwear analysis correspond with those from trace-element analysis and showed that the population consumed a mixed diet. The density of the scratches indicates that the diet contained a considerable vegetable component. The high number of vertical scratches and their high average length suggest that individuals also consumed a large portion of meat. The results of both analyses showed that there were also individuals whose diet had probably been poor, i.e. richer in animal protein, which probably could be related to their health or social status in the population.

  11. Trace elements distribution in bottom sediments from Amazon River estuary

    International Nuclear Information System (INIS)

    Lara, L.B.L.S.; Nadai Fernandes, E. de; Oliveira, H. de; Bacchi, M.A.

    1994-01-01

    The Amazon River discharges into a dynamic marine environment where there have been many interactive processes affecting dissolved and particulate solids, either those settling on the shelf or reaching the ocean. Trace elemental concentration, especially of the rare earth elements, have been determined by neutron activation analysis in sixty bottom sediment samples of the Amazon River estuary, providing information for the spatial and temporal variation study of those elements. (author). 16 refs, 6 figs, 3 tabs

  12. Simulation of Iranian total mixed diets and their analysis for essential and toxic trace elements using nuclear and complementary analytical techniques

    International Nuclear Information System (INIS)

    Gharib, A.G.; Ahmadiniar, A.; Aminpour, A.A.

    2001-01-01

    Neutron activation analysis, inductively coupled plasma emission spectrometry (ICP-ES) and atomic absorption spectroscopy (AAS) have been used to determine actual daily dietary intakes of minerals and trace elements in the Iranian population. Trace elemental analysis of daily diets of the Iranian population differentiated with respect to food habits, geographical variability, literacy and income is examined. Three study groups in five regions were defined. Thirty total daily diet samples were prepared based on the method of dietary records. Also a few samples representing the intakes of two other study groups, males and females, were prepared by the duplicate diet method. Therefore, not only representative dietary patterns of almost all adult people in Iran are covered in a pilot study, but also the validity of the sampling methodology for total mixed diet simulation is checked. (author)

  13. The chemical speciation and analysis of trace elements in sediment with Neutron Activation Analytical method(NAA) and atomic mass spectrometry

    International Nuclear Information System (INIS)

    Nam, Sang-Ho; Kim, Jae-Jin; Chung, Yong-Sam; Kim, Sun-Ha

    2003-01-01

    In this research, first of all, the analytical methods for the determination of major elements in sediment have been developed with ICP-MS (Inductively Coupled Plasma Mass Spectrometry). The analytical results of major elements (Al, Ca, K, Fe, Mg) with Cool ICP-MS were much better than those with normal ICP-MS. The analytical results were compared with those of NAA (Neutron Activation Analysis). NAA were a little superior to ICP-MS for the determination of major elements in sediment as a non-destructive trace analytical trace analytical method. The analytical methods for the determination of minor elements (Cr, Ce, U, Co, Pb, As, Se) have been also developed with ICP-MS. The analytical results by standard calibration curve with ICP-MS were not accurate due to the matrix interferences. Thus, the internal standard method was applied, then the analytical results for minor elements with ICP-MS were greatly improved. The analytical results obtained by ICP-MS were compared with those obtained by NAA. It showed that the two analytical methods have great capabilities for the determination of minor elements in sediments. Accordingly, the NAA will plan an important role in analysis of environment sample with complex matrix. ICP-MS also will play an important role because it has a great capability for the determination of Pb that could not be determined by NAA

  14. Coordinated U-Pb geochronology, trace element, Ti-in-zircon thermometry and microstructural analysis of Apollo zircons

    Science.gov (United States)

    Crow, Carolyn A.; McKeegan, Kevin D.; Moser, Desmond E.

    2017-04-01

    We present the results of a coordinated SIMS U-Pb, trace element, Ti-in-zircon thermometry, and microstructural study of 155 lunar zircons separated from Apollo 14, 15, and 17 breccia and soil samples that help resolve discrepancies between the zircon data, the lunar whole rock history and lunar magma ocean crystallization models. The majority of lunar grains are detrital fragments, some nearly 1 mm in length, of large parent crystals suggesting that they crystallized in highly enriched KREEP magmas. The zircon age distributions for all three landing sites exhibit an abundance of ages at ∼4.33 Ga, however they differ in that only Apollo 14 samples have a population of zircons with ages between 4.1 and 3.9 Ga. These younger grains comprise only 10% of all dated lunar zircons and are usually small and highly shocked making them more susceptible to Pb-loss. These observations suggest that the majority of zircons crystallized before 4.1 Ga and that KREEP magmatism had predominantly ceased by this time. We also observed that trace element analyses are easily affected by contributions from inclusions (typically injected impact melt) within SIMS analyses spots. After filtering for these effects, rare-earth element (REE) abundances of pristine zircon are consistent with one pattern characterized by a negative Eu anomaly and no positive Ce anomaly, implying that the zircons formed in a reducing environment. This inference is consistent with crystallization temperatures based on measured Ti concentrations and new estimates of oxide activities which imply temperatures ranging between 958 ± 57 and 1321 ± 100 °C, suggesting that zircon parent magmas were anhydrous. Together, the lunar zircon ages and trace elements are consistent with a ⩽300 My duration of KREEP magmatism under anhydrous, reducing conditions. We also report two granular texture zircons that contain baddeleyite cores, which both yield 207Pb-206Pb ages of 4.33 Ga. These grains are our best constraints on

  15. Trace analysis by TXRF

    International Nuclear Information System (INIS)

    Hockett, R.S.

    1995-01-01

    Total reflection X-Ray Fluorescence (TXRF) originally was developed for trace analysis of small residues but has become a widespread method for measuring trace surface metal contamination an semiconductor substrates. It is estimated that approximately 100 TXRF instruments are in se in the semiconductor industry worldwide, and approximately half that for residue analysis x analytical laboratories. TXRF instrumentation is available today for reaching detection limits d the order of 10 9 atoms/cm 2 . This review emphasizes some of the more recent developments in TXRF for trace analysis, in particular with the use of synchrotron x-ray sources (SR-TXRF). There is some promise of reaching 10 7 atoms/cm 2 detection limits for surface analysis of semi-conductor substrates. 19 refs

  16. Novel use of field-portable-XRF for the direct analysis of trace elements in marine macroalgae.

    Science.gov (United States)

    Bull, Annie; Brown, Murray T; Turner, Andrew

    2017-01-01

    Samples of dried marine macroalgae (Fucus serratus, Palmaria palmata and Ulva lactuca) have been analysed for trace elements by a novel, non-destructive approach involving a Niton field-portable-X-ray fluorescence (FP-XRF) spectrometer configured in a low density plastics mode with thickness correction. Detection limits for a 200-s counting time ranged from palmata to several tens of μg g -1 for Cd, Sb and Sn in all species tested. Arsenic, Cu, Pb and Zn were detected by the XRF in samples collected from a protected beach (n = 18) and in samples therefrom that had been exposed to additional aqueous elements in combination (n = 72) with concentrations returned (in μg g -1 ) ranging from 3.9 to 39.7 for As, 13.0 to 307 for Cu, 6.1 to 14.7 for Pb and 12.5 to 522 for Zn. Independent measurements of trace elements in the macroalgae by ICP-MS following nitric acid digestion revealed a direct and significant proportionality with concentrations returned by the XRF, with slopes of the XRF-ICP relationships (As = 1.0; Cu = 2.3; Pb = 2.4; Zn = 1.7) that can be used to calibrate the instrument for direct measurements. The approach shows potential for the in situ monitoring of macroalgae in coastal regions that is currently being investigated. Copyright © 2016 Elsevier Ltd. All rights reserved.

  17. Physico-chemical speciation of trace elements in river water

    Energy Technology Data Exchange (ETDEWEB)

    Tanizaki, Yoshiyuki; Shimokawa, Toshinari (Tokyo Metropolitan Isotope Research Center (Japan)); Yamazaki, Masao

    1990-01-01

    Size fractionation (ultrafiltration) and gamma-ray irradiation methods have been used for the speciation of trace elements in river waters. The size distribution was clarified for 37 elements by neutron activation analysis. The chemical forms (organics or inorganics) of trace elements in the waters were discussed by comparison of their size distribution for the gamma-ray irradiated water samples and those for the unirradiated samples. As the results, it was proved that; (1) Alkali and alkaline-earth elements, halogens, Al, Au, Mn, Sb, V, etc were tend to dissolve in the waters as simple inorganic ions and/or hydroxo complexes with smaller size. (2) The elements As, Mo, U, W were present as both species, simple ions and inorganic complexes. (3) The dissolved species of rare-earth elements, Ag, Co, Cr, Fe, Hf, Ir, Ni, Sc, Se, Zn etc were tend to form the complexes with naturally-occurring organic substances such as humic and fluvic acid. (author).

  18. Evaluation of trace element status of organic dairy cattle.

    Science.gov (United States)

    Orjales, I; Herrero-Latorre, C; Miranda, M; Rey-Crespo, F; Rodríguez-Bermúdez, R; López-Alonso, M

    2017-11-06

    The present study aimed to evaluate trace mineral status of organic dairy herds in northern Spain and the sources of minerals in different types of feed. Blood samples from organic and conventional dairy cattle and feed samples from the respective farms were analysed by inductively coupled plasma mass spectrometry to determine the concentrations of the essential trace elements (cobalt (Co), chromium (Cr), copper (Cu), iron (Fe), iodine (I), manganese (Mn), molybdenum (Mo), nickel (Ni), selenium (Se) and zinc (Zn)) and toxic trace elements (arsenic (As), cadmium (Cd), mercury (Hg) and lead (Pb)). Overall, no differences between organic and conventional farms were detected in serum concentrations of essential and toxic trace elements (except for higher concentrations of Cd on the organic farms), although a high level of inter-farm variation was detected in the organic systems, indicating that organic production greatly depends on the specific local conditions. The dietary concentrations of the essential trace elements I, Cu, Se and Zn were significantly higher in the conventional than in the organic systems, which can be attributed to the high concentration of these minerals in the concentrate feed. No differences in the concentrations of trace minerals were found in the other types of feed. Multivariate chemometric analysis was conducted to determine the contribution of different feed sources to the trace element status of the cattle. Concentrate samples were mainly associated with Co, Cu, I, Se and Zn (i.e. with the elements supplemented in this type of feed). However, pasture and grass silage were associated with soil-derived elements (As, Cr, Fe and Pb) which cattle may thus ingest during grazing.

  19. Application of neutron activation analysis to the determination of minor-and trace elements in magnesite ore

    International Nuclear Information System (INIS)

    Sepulveda Munita, C.J.A.; Atalla, L.T.

    1979-01-01

    A method employing analysis with thermal neutrons was developed for analyzing magnesite samples coming from the States do Ceara and Bahia (Brazil). Ten samples were analyzed. Qualitative analysis of the samples indicated the presence of Mn, Fe, Sc, Ca, Cu, Co and some of the lanthanides. Mn was analyzed by non-destructive activation analysis and the other elements were analyzed, individually or in group, after sample dissolution with 8 N HCl solution. A detailed study of the possible interferences in neutron activation analysis of the elements considered was also undertaken. The precision and accuracy of the results obtained and the sensitivity of the method are discussed. (Author) [pt

  20. Trace element distribution in geological crystals

    Energy Technology Data Exchange (ETDEWEB)

    Den Besten, J.L.; Jamieson, D.N.; Weiser, P.S. [Melbourne Univ., Parkville, VIC (Australia). School of Physics

    1996-12-31

    Channelling is a useful microprobe technique for determining the structure of crystals, but until now has not been performed on geological crystals. The composition has been investigated rather than the structure, which can further explain the origin of the crystal and provide useful information on the substitutionality of trace elements. This may then lead to applications of extraction of valuable metals and semiconductor electronics. Natural crystals of pyrite, FeS{sub 2}, which contains a substantial concentration of gold were channeled and examined to identify the channel axis orientation. Rutherford Backscattering (RBS) and Particle Induced X-Ray Emission (PIXE) spectra using MeV ions were obtained in the experiment to provide a comparison of lattice and non-lattice trace elements. 3 figs.

  1. The use of neutron activation analysis for particle size fractionation and chemical characterization of trace elements in urban air particulate matter

    International Nuclear Information System (INIS)

    Rizzio, E.; Bergamaschi, G.; Profumo, A.; Gallorini, M.

    2001-01-01

    The concentration of more than 25 trace elements have been determined in total air particulate matter and in the size segregated fractions from the urban area of Pavia (North Italy). The PM10 fraction was also collected and analyzed. A study of the solubility in water and in physiological solution of the trace elements contained in the PM10 was also carried out. The resulting solutions were further submitted to column chromatography using Chelex 100 to perform a preliminary chemical characterization. INAA was used as the main analytical technique. ET-AAS was used for all Pb and Cd measurements and, in some cases, for the analysis of V, Mn, Cu and Ni. (author)

  2. Assessment of trace element stabilization in soil

    OpenAIRE

    Kumpiene, Jurate

    2005-01-01

    The thesis deals with the remediation of trace element contaminated soil by the chemical stabilization technique. The objective is to complement the knowledge about possibilities of applying the stabilization either (1) as an alternate soil remediation method to excavation and landfilling or (2) for a pre-treatment of contaminated soil before landfilling. The work is based on two case studies of the stabilization of 1) Cr, Cu, As, and Zn contaminated soil using metallic iron and 2) Pb and Cu ...

  3. Determination of rare-earths and other trace elements in neo proterozoic-neo paleozoic dykes from Ceara state, Brazil, by neutron activation analysis

    Energy Technology Data Exchange (ETDEWEB)

    Anjos, Rafael Martins dos; Figueiredo, Ana M.G., E-mail: rafael.anjos@usp.b, E-mail: anamaria@ipen.b [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil). Centro do Reator Nuclear de Pesquisas. Lab. de Analise por Ativacao com Neutrons; Cardoso, Gustavo Luan; Marques, Leila S., E-mail: leila@iag.usp.b [Universidade de Sao Paulo (IAG/USP), SP (Brazil). Inst. de Astronomia, Geofisica e Ciencias Atmosfericas

    2011-07-01

    Trace elements such as rare earths, U, Th, Ta, Ba and Hf can be very useful in petrogenetic studies of igneous and metamorphic rocks, giving information about the origin and evolution of magmas. Instrumental Neutron Activation Analysis (INAA) is an accurate and precise for trace element analysis in geological samples, and provides the information required for this kind of studies. In this study, rare earths and incompatible trace elements were determined by INAA in the geological reference materials GS-N and BE-N, to quality control, and for the investigation of acid dykes of neo proterozoic-neo paleozoic ages, which outcrop in the Medio Coreau and Ceara Central domains from the Borborema Province (Ceara State). The powdered samples (particle sizes less than 100 mesh), crushed by using a mechanical agate mortar grinder, were irradiated at the IEA-R1 nuclear reactor at IPEN-CNEN/SP, and the induced activity was measured by high resolution gamma-ray spectrometry. The accuracy and precision of the method were evaluated and preliminary results of dyke samples are presented. (author)

  4. Dietary patterns and trace elements intake evaluation

    International Nuclear Information System (INIS)

    Rahman, A.; Waheed, S.; Zaidi, J.H.; Ahmad, S.

    1998-01-01

    The dietary patterns and trace element contents of the integrated diets of middle income population in Gujranwala and of Islamabad have been studied and dietary intake of winter and summer are given. An overview of the elemental concentration in the two sets of integrated diets reveals similar zinc and manganese concentrations; comparatively higher nickel, selenium and potassium concentrations in Gujranwala and higher chromium, cesium, scandium, sodium and chlorine concentrations in Islamabad. These results undoubtedly reflect the difference in food selection and habits of the two populations, the influence of soil content and industrial pollution

  5. Analysis of trace elements in gold alloys by SR-XRF at high energy at the BAMline

    International Nuclear Information System (INIS)

    Guerra, M.F.; Radtke, M.; Reiche, I.; Riesemeier, H.; Strub, E.

    2008-01-01

    Measuring in a non-destructive way the characteristic trace elements of the metal allows following the circulation of gold in the past. The aim of this work is to probe the possibilities of X-ray fluorescence with high energy synchrotron radiation (SR-XRF) at the BAMline at BESSY II to determine the concentration of Pt in ancient gold alloys. A HP-Ge detector was used to measure the Pt K-lines excited with an incident energy of 79.5 keV. Data processing was done by subtraction of a Pt free gold standard spectrum from the spectrum of the sample. Depending on the sample composition, the MDL ranges between 40 and 90 ppm. The first results obtained for a small set of gold alloys of different thickness, size and composition showed that high energy SR-XRF is a significant method for the non-destructive determination of Pt in gold

  6. The Role of Trace Elements in Tinnitus.

    Science.gov (United States)

    Yaşar, Mehmet; Şahin, Mehmet İlhan; Karakükçü, Çiğdem; Güneri, Erhan; Doğan, Murat; Sağıt, Mustafa

    2017-03-01

    In this study, we aimed to investigate the role of three trace elements, namely, zinc, copper, and lead, in tinnitus by analyzing the serum level of copper and lead and both the serum and tissue level of zinc. Eighty patients, who applied to outpatient otolaryngology clinic with the complaints of having tinnitus, and 28 healthy volunteers were included. High-frequency audiometry was performed, and participants who had hearing loss according to the pure tone average were excluded; tinnitus frequency and loudness were determined and tinnitus reaction questionnaire scores were obtained from the patients. Of all the participants, serum zinc, copper, and lead values were measured; moreover, zinc levels were examined in hair samples. The levels of trace elements were compared between tinnitus and control groups. The level of copper was found to be significantly lower in the tinnitus group (p = 0.02), but there was no significant difference between the groups in terms of the levels of zinc, neither in serum nor in hair, and lead in serum (p > 0.05). The lack of trace elements, especially that of "zinc," have been doubted for the etiopathogenesis of tinnitus in the literature; however, we only found copper levels to be low in patients having tinnitus.

  7. Trace Elements in Teeth by ICPMS

    International Nuclear Information System (INIS)

    Zahran, N.F.; Helal, A.I.; Amr, M.A.; Amr, M.A.; Al-saad, K.A.

    2008-01-01

    Teeth are reported to be suitable indicators of trace element exposure from environment and nutritional status. Inductively coupled plasma mass spectrometry (ICP-MS) is used to compare the trace element content of children's primary teeth and adult teeth. Primary teeth are collected from 28 children and 42 adult from non-industrial City. The data are assessed statistically using t-tests. The adult teeth contained significantly greater concentrations of Na, Mg, Al, Fe, Ni, Cu, Sr, Cd, Ba, Pb and U and significantly less Mn, Co, As, Se, Mo and Bi than the children teeth. Additional measurements on adult teeth pulps are performed. Comparison between trace element concentrations in health and caries teeth pulps show that the mean concentrations of Na, Al, K, Cr, Mn, Co, Cu, Zn, Mo, Ag, Bi and U are lower in caries than healthy teeth pulps. On the other hand, the mean concentrations of Mg, Cd and Pb are higher in caries samples than healthy teeth pulps

  8. Concentration of trace elements on branded cigarette in Malaysia

    Science.gov (United States)

    Azman, Muhammad Azfar; Yasir, Muhamad Samudi; Rahman, Irman Abdul; Hamzah, Suhaimi; Rahman, Shamsiah Abdul; Elias, Md Suhaimi; Abdullah, Nazaratul Ashifa; Hashim, Azian; Shukor, Shakirah Abd

    2016-01-01

    Tobacco is a plant that is used as a recreational drug since the beginning of its use by the Native Americans. Now with the development of the tobacco industry, smoking has become a norm for the public in Malaysia. Trace elements in plants are mostly due to the uptake processes from the soils into the roots of the plants. The concentration of the elements may also be influenced by the elements contained in the water and also fertilizers. This paper aim to analyze the concentration of the trace elements contained in the branded cigarettes sold in Malaysia by utilizing the neutron activation analysis. The tobaccos were taken out from the cigarettes. The collected samples were air dried and passed through 2 mm sieve. Instrumental Neutron Activation Analysis (NAA) has been used for the determination of trace elements. Samples were activated in the Nuclear Malaysia Triga Mark II reactor with a neutron flux of 2.0 x 1012 n cm-2 s-1. The samples then were analyzed using ORTEC Gamma Spectrometer a co-axial n-type HPGe detector with resolution of 2.0 keV at 1332 keV and relative efficiency of 20%. The data obtained could help in assessing the concentration of the trace elements that complying with the standard limitation dose proposed by World Health Organization (WHO).

  9. Concentration of trace elements on branded cigarette in Malaysia

    International Nuclear Information System (INIS)

    Azman, Muhammad Azfar; Hamzah, Suhaimi; Rahman, Shamsiah Abdul; Elias, Md Suhaimi; Abdullah, Nazaratul Ashifa; Hashim, Azian; Shukor, Shakirah Abd; Yasir, Muhamad Samudi; Rahman, Irman Abdul

    2016-01-01

    Tobacco is a plant that is used as a recreational drug since the beginning of its use by the Native Americans. Now with the development of the tobacco industry, smoking has become a norm for the public in Malaysia. Trace elements in plants are mostly due to the uptake processes from the soils into the roots of the plants. The concentration of the elements may also be influenced by the elements contained in the water and also fertilizers. This paper aim to analyze the concentration of the trace elements contained in the branded cigarettes sold in Malaysia by utilizing the neutron activation analysis. The tobaccos were taken out from the cigarettes. The collected samples were air dried and passed through 2 mm sieve. Instrumental Neutron Activation Analysis (NAA) has been used for the determination of trace elements. Samples were activated in the Nuclear Malaysia Triga Mark II reactor with a neutron flux of 2.0 x 10 12 n cm -2 s -1 . The samples then were analyzed using ORTEC Gamma Spectrometer a co-axial n-type HPGe detector with resolution of 2.0 keV at 1332 keV and relative efficiency of 20%. The data obtained could help in assessing the concentration of the trace elements that complying with the standard limitation dose proposed by World Health Organization (WHO)

  10. Concentration of trace elements on branded cigarette in Malaysia

    Energy Technology Data Exchange (ETDEWEB)

    Azman, Muhammad Azfar, E-mail: m-azfar@nuclearmalaysia.gov.my; Hamzah, Suhaimi; Rahman, Shamsiah Abdul; Elias, Md Suhaimi; Abdullah, Nazaratul Ashifa; Hashim, Azian; Shukor, Shakirah Abd [Blok 18, Makmal Kimia Analisis (ACA/BAS), Agensi Nuklear Malaysia, 43000 Kajang, Selangor (Malaysia); Yasir, Muhamad Samudi; Rahman, Irman Abdul [Bangunan Sains Nuklear, Fakulti Sains & Teknologi, UKM Bangi, 43600 Bangi, Selangor (Malaysia)

    2016-01-22

    Tobacco is a plant that is used as a recreational drug since the beginning of its use by the Native Americans. Now with the development of the tobacco industry, smoking has become a norm for the public in Malaysia. Trace elements in plants are mostly due to the uptake processes from the soils into the roots of the plants. The concentration of the elements may also be influenced by the elements contained in the water and also fertilizers. This paper aim to analyze the concentration of the trace elements contained in the branded cigarettes sold in Malaysia by utilizing the neutron activation analysis. The tobaccos were taken out from the cigarettes. The collected samples were air dried and passed through 2 mm sieve. Instrumental Neutron Activation Analysis (NAA) has been used for the determination of trace elements. Samples were activated in the Nuclear Malaysia Triga Mark II reactor with a neutron flux of 2.0 x 10{sup 12} n cm{sup -2} s{sup -1}. The samples then were analyzed using ORTEC Gamma Spectrometer a co-axial n-type HPGe detector with resolution of 2.0 keV at 1332 keV and relative efficiency of 20%. The data obtained could help in assessing the concentration of the trace elements that complying with the standard limitation dose proposed by World Health Organization (WHO)

  11. The trace element analysis of ancient Indian coins using proton induced x-ray emission (PIXE) technique

    International Nuclear Information System (INIS)

    PURI, N.K.; HAJIVALIEI, M.; BEDI, S.C.; SINGH, N.; GOVIL, I.M.; GARG, M.L.; HANDA, D.K.; GOVIL, K.L.; ROUT, B.; VIJAYAN, V.

    2004-01-01

    Elemental analysis of ancient Indian coins viz. thirty-three punched marked coins (6 th century B.C.), fifty-nine coins belonging to Kusanas (78-250 A.D) and twenty-five coins belonging to medieval period (11 th -14 th century A.D), from India have been analysed using Proton Induced X-ray Emission (PIXE) technique. The elements namely S, Ca, Fe, Ag, Cu, Ni and Pb were detected in most of the punch-marked coins while elements namely S, Cl, K, Ca, Ti, Cr, Mn, Fe, Ni, Cu, As and Zn were detected in most of the Kusanas coins and the S, Ca, Fe, Cu, Ag, Sn, Pb were detected in 11 th -14 th century A.D. coins. Based on the elemental analysis different hypotheses put forward in the earlier literature were examined. This is the first attempt where reasonable number of ancient coins belonging to different periods were analysed by modern non destructive multi-elemental technique such as PIXE and has put the importance of the elemental analysis of ancient Indian coins in the proper perspective

  12. Wet deposition flux of trace elements to the Adirondack region

    International Nuclear Information System (INIS)

    Huang, X.; Keskin, S.S.; Gullu, G.; Olmez, I.

    2001-01-01

    Wet deposition samples from two locations in the Adirondack region of New York were analyzed for trace elemental composition by instrumental neutron activation analysis. Annual fluxes of the measured species were determined by precipitation-weighted and linear-regression methods. Despite several episodes of high deposition fluxes, the cumulative areal wet deposition of trace elements increased fairly linearly (r 2 > 0.9) over the two year sampling period at both sites. This implies that short duration sampling programs may be used to estimate long-term fluxes and cumulative wet deposition impacts. Based on the magnitude of their fluxes, the measured species have been divided into four groups: acidic anions, electroneutral balancing cations, and minor and trace elements of anthropogenic origin. (author)

  13. Trace elements distribution in the Amazon floodplain soils

    International Nuclear Information System (INIS)

    Fernandes, E.A.N.; Ferraz, E.S.B.; Oliveira, H.

    1994-01-01

    Neutron activation analysis was performed on aluvial soil samples from several sites on the foodplains of the Amazon River and its major tributaries for trace elements determination. The spatial and temporal variations of chemical composition of floodland sediments in the Amazon basin are discussed. No significant difference was found in trace elemental distribution in the floodland soils along the Amazon main channel, even after the source material has been progressively diluted with that from lowland draining tributaries. It was also seen that the average chemical composition of floodplain soils compares well with that of the suspended sedimets. (author) 12 refs.; 5 figs.; 2 tabs

  14. Determination of trace elements in electronic materials by NAA

    International Nuclear Information System (INIS)

    Kobayashi, Kenji

    1986-01-01

    Trace amounts of elements in electronic materials were determined by instrumental neutron activation analysis (INAA), re-activation analysis and substoichiometric radioactivation analysis using gamma-ray spectrometry. Ten elements (Cr, Cu, Fe, Zn, Co, Eu, Ir, Sb, Sc, Tb) in gallium arsenide single crystal were determined by INAA and substoichiometric radioactivation analysis. Trace level of chromium (10 13 atoms/cm 3 ) and zinc (10 14 atoms/cm 3 ) in gallium arsenide single crystal were determined by INAA. The chromium concentrations in horizontal Bridgmangrown semi-insulating gallium arsenide ingot were ranged from 1.2 x 10 16 atoms/cm 3 at seed end to 3.5 x 10 16 atoms/cm 3 at tail end. The trace determinations of iron (10 14 atoms/cm 3 ) and copper (10 14 atoms/cm 3 ) in silicon, gallium arsenide and indium phoshide single crystals were carried out by substoichiometric radioactivation analysis. The reactivation analysis for the multielement determination of indium phosphide single crystal was carried out and nineteen elements were determined simultaneously by gamma-ray spectrometry. Eleven elements (Ag, As, Br, Co, Cr, Fe, K, Mn, Sb, Sc, Zn) in four NIES standard reference materials (Pond Sediment, Chlorella, Mussel and Tea Leaves) and seven elements (Co, Cr, Eu, Fe, Sc, Tb, Yb) in two NBS glasses (SRM-615 and SRM-613) were determined by INAA and substoichiometric radioactivation analysis and the analytical results obtained by the methods were in good agreement with certified values by NIES and NBS. (author)

  15. trace element determination in municipal water supply of Damaturu

    African Journals Online (AJOL)

    DR. AMINU

    ABSTRACT. Groundwater is the only source of drinking water for residents of Damaturu Metropolis. This is ... result of the analysis shows that metals such as Lead, Cadmium, Zinc and Copper were not found in all the water samples, ... Key words: Contamination, Trace elements, Toxic, underground water. INTRODUCTION.

  16. Environmental lichenology: Biomonitoring of trace element air pollution

    International Nuclear Information System (INIS)

    Sukhodub, L.S.; Sulkio-Cleff, B.

    2001-01-01

    The review of application of lichens and mosses as biomonitors of air pollution have been presented. The neutron activation analysis and atomic absorption spectroscopy have been used for trace element content determination in lichens and mosses taken from different regions of Europe

  17. Two-dimensional micro-beam imaging of trace elements in a single plankton measured by a synchrotron radiation X-ray fluorescence analysis

    International Nuclear Information System (INIS)

    Ezoe, Masako; Sasaki, Miho; Hokura, Akiko; Nakai, Izumi; Terada, Yasuko; Yoshinaga, Tatsuki; Tukamoto, Katsumi; Hagiwara, Atsushi

    2002-01-01

    Two-dimensional imaging and a quantitative analysis of trace elements in rotifer, Brachionus plicatilis, belonging to zooplankton, were carried out by a synchrotron radiation X-ray fluorescence analysis (SR-XRF). The XRF imaging revealed that female rotifers accumulated Fe and Zn in the digestive organ and Fe, Zn, Cu, and Ca in the sexual organs, while the Mn level was high in the head. From a quantitative analysis by inductively coupled plasma mass spectrometry (ICP-MS), we found that rotifers eat the chlorella and accumulate the above elements in the body. The result of quantitative analyses of Mn, Cu, and Zn by SR-XRF in a single sample is in fair agreement with the average values determined by ICP-MS analyses, which were obtained by measuring a large number of rotifers, digested by nitric acid. The present study has demonstrated that SR-XRF is an effective tool for the trace element analysis of a single individual of rotifer. (author)

  18. Trace element changes in cardiovascular diseases

    Science.gov (United States)

    Pinheiro, T.; Fernandes, R.; Maenhaut, W.; Hebbrecht, G.; Wätjen, U.; Halpern, M. J.

    1993-04-01

    Artery samples and five different brain structures originating from both atherosclerosis affected and healthy Portuguese individuals were examined for their elemental content. Particle-induced X-ray emission (PIXE) was used to determine K, Ca, Mn, Fe, Cu, Zn, Se and Rb in all the tissues studied. The most prominent differences between the pathological and reference data were those for Mn, Fe, Cu and Zn in the nucleus caudatus, putamen and substantia nigra brain regions. In the arteries a significant increase in Ca and Mn content was observed, whereas the K and Fe content declined. The decreased K and Rb content in the five brain structures from the pathological group and the changes for Mn in the nucleus caudatus, putamen and substantia nigra regions can be associated with aging. However, age cannot explain the other trace element alterations, e.g., for Fe, Cu and Zn. Most likely, the changes for these elements are due to atherosclerosis progression.

  19. The role of trace elements in male infertility.

    Science.gov (United States)

    Abou-Shakra, F R; Ward, N I; Everard, D M

    1989-08-01

    The elemental status of seminal plasma collected from four populations subdivided on the basis of sperm counts is presented. Elemental analysis was performed by inductively coupled plasma-source mass spectrometry (ICP-MS) for calcium, cadmium, cobalt, chromium, copper, iron, magnesium, manganese, molybdenum, nickel, lead, rubidium, selenium, vanadium, and zinc. The majority of elements reflected no statistically significant differences among the four groups. The role of trace elements in infertility may be more directly related to sperm and whole semen than seminal plasma levels.

  20. Trace element impurity determination in aspirin tablets by INAA

    International Nuclear Information System (INIS)

    Miyoshi, E.K.; Saiki, M.

    2009-01-01

    Instrumental neutron activation analysis (INAA) was applied to assess trace element concentrations in six samples of aspirin tablets acquired in Sao Paulo city, Brazil. Concentrations of the elements Br, Ca, Co, Cr, Fe, K, La, Na, Sc and Zn were determined. Comparisons were made between the results obtained with published data for aspirins from foreign countries. Certified reference materials, INCT-MPH-2 Mixed Polish Herbs were analyzed for quality control of the analytical results. (author)

  1. The trace elements selenium, copper and zinc in pediatric practice

    NARCIS (Netherlands)

    M. van Caillie-Bertrand (Micheline)

    1985-01-01

    textabstractThe aim of the studies presented in this thesis was to investigate some pediatric aspects of trace element metabolism .The effects are described of 1) inadequate trace element intake , 2) trace element malabsorption mine and 4) sulphate.Within ,3) urinary losses during therapy with

  2. Trace element geochemistry of Amba Dongar carbonatite complex ...

    Indian Academy of Sciences (India)

    R. Narasimhan (Krishtel eMaging) 1461 1996 Oct 15 13:05:22

    melt partition coefficients for various trace elements, and the observed data from carbonatites, we have tried to simulate trace ... Keywords. Carbonatite; Amba Dongar; India; liquid immiscibility; trace elements; REE. Proc. Indian Acad. ...... clature, average chemical compositions and element dis- tribution; In: Carbonatites: ...

  3. Quantitative analysis of major and trace elements in NH4HF2-modified silicate rock powders by laser ablation - inductively coupled plasma mass spectrometry.

    Science.gov (United States)

    Zhang, Wen; Hu, Zhaochu; Liu, Yongsheng; Yang, Wenwu; Chen, Haihong; Hu, Shenghong; Xiao, Hongyan

    2017-08-29

    In this paper, we described a NH 4 HF 2 digestion method as sample preparation for the rapid determination of major and trace elements in silicate rocks using laser ablation-inductively coupled plasma mass spectrometry (LA-ICP-MS). Sample powders digested by NH 4 HF 2 at 230 °C for 3 h form ultrafine powders with a typical grain size d 80  rocks have a consistent grain morphology and size, allowing us to produce pressed powder pellets that have excellent cohesion and homogeneity suitable for laser ablation micro-analysis without the addition of binder. The influences of the digestion parameters were investigated and optimized, including the evaporation stage of removing residual NH 4 HF 2 , sample homogenization, selection of the digestion vessel and calibration strategy of quantitative analysis. The optimized NH 4 HF 2 digestion method was applied to dissolve six silicate rock reference materials (BCR-2, BHVO-2, AGV-2, RGM-2, GSP-2, GSR-1) covering a wide range of rock types. Ten major elements and thirty-five trace elements were simultaneously analyzed by LA-ICP-MS. The analytical results of the six reference materials generally agreed with the recommended values, with discrepancies of less than 10% for most elements. The analytical precision is within 5% for most major elements and within 10% for most trace elements. Compared with previous methods of LA-ICP-MS bulk analysis, our method enables the complete dissolution of refractory minerals, such as zircon, in intermediate-acidic intrusive rocks and limits contamination as well as the loss of volatile elements. Moreover, there are many advantages for the new technique, including reducing matrix effects between reference materials and samples, spiking the internal standard simply and feasibly and sample batch processing. The applicability filed of the new technique in this study was focused on the whole-rock analysis of igneous rock samples, which are from basic rocks to acid rocks (45% rock analysis

  4. Trace elements in renal disease and hemodialysis

    International Nuclear Information System (INIS)

    Miura, Yoshinori; Nakai, Keiko; Suwabe, Akira; Sera, Koichiro

    2002-01-01

    A number of considerations suggest that trace element disturbances might occur in patients with renal disease and in hemodialysis (HD) patients. Using particle induced X-ray emission, we demonstrated the relations between serum concentration, urinary excretion of the trace elements and creatinine clearance (Ccr) in randomized 50 patients. To estimate the effects of HD, we also observed the changes of these elements in serum and dialysis fluids during HD. Urinary silicon excretion decreased, and serum silicon concentration increased as Ccr decreased, with significant correlation (r=0.702, p<0.001 and r=0.676, p<0.0001, respectively). We also observed the increase of serum silicon, and the decrease of silicon in dialysis fluids during HD. These results suggested that reduced renal function and also dialysis contributed to silicon accumulation. Although serum selenium decreased significantly according to Ccr decrease (r=0.452, p<0.01), we could detect no change in urinary selenium excretion and no transfer during HD. Serum bromine and urinary excretion of bromine did not correlate to Ccr. However we observed a bromine transfer from the serum to the dialysis fluid that contributed to the serum bromine decrease in HD patients

  5. Sources of trace elements in total diet. A statistical approach

    International Nuclear Information System (INIS)

    Aras, N.K.; Chatt, A.

    2004-01-01

    Sixteen total diet samples have been collected from two socioeconomic groups in Turkey by duplicate portion techniques. Samples were homogenized with titanium-blade homogenizer, freeze dried and analyzed for their minor and trace elements mostly by neutron activation analysis. Bread and flour samples were also collected from the same regions and analyzed similarly by instrumental neutron activation analysis. Concentrations of more than 25 elements in total diets, bread and flour, and fiber and phytate in total diets have been determined. Daily dietary intakes of these population groups, probable source of elements through correlation coefficients, and enrichment factor calculations have been determined. (author)

  6. Trace elemental analysis of school chalk using energy dispersive X-ray florescence spectroscopy (ED-XRF)

    Science.gov (United States)

    Maruthi, Y. A.; Das, N. Lakshmana; Ramprasad, S.; Ram, S. S.; Sudarshan, M.

    2015-08-01

    The present studies focus the quantitative analysis of elements in school chalk to ensure the safety of its use. The elements like Calcium (Ca), Aluminum (Al), Iron (Fe), Silicon (Si) and Chromium (Cr) were analyzed from settled chalk dust samples collected from five classrooms (CD-1) and also from another set of unused chalk samples collected from local market (CD-2) using Energy Dispersive X-Ray florescence(ED-XRF) spectroscopy. Presence of these elements in significant concentrations in school chalk confirmed that, it is an irritant and occupational hazard. It is suggested to use protective equipments like filtered mask for mouth, nose and chalk holders. This study also suggested using the advanced mode of techniques like Digital boards, marker boards and power point presentations to mitigate the occupational hazard for classroom chalk

  7. Neutron activation analysis determination of trace elements in suspended particulate material and in central Thyrrenian sea sediments

    International Nuclear Information System (INIS)

    Madaro, M.; Moauro, R.; Boniforti, R.

    1985-01-01

    Neutron activation analysis and gamma-spectrometry have been applied to the instrumental determination of 26 elements (As, Au, Ca, Ce, Co, Cr, Cs, Eu, Fe, Hf, Hg, La, Lu, Mn, Rb, Sb, Sc, Se, Sm, Ta, Tb, Th, W, Yb, Zn, Zr) in samples of suspended particulate matter and sediments collected in the stretch of Tyrrhenian Sea between the Volturno River mouth and the Cape of Circeo. Some of these elements have particular importance because they can be toxic to the organisms or can be used as tracers in the aquatic environment of radioisotopes generated in activation or fission processes. Results show that some elements, not constituting particular crystal lattices, are more concentrated in particulate matter than in sediments. Such results agree with the hypothesis, supported also by others, that particulate matter acts as a scavenger with respect to most microelements, because of both biological and physico-chemical phenomena

  8. Classification of cultivated mussels from Galicia (Northwest Spain) with European Protected Designation of Origin using trace element fingerprint and chemometric analysis

    International Nuclear Information System (INIS)

    Costas-Rodriguez, M.; Lavilla, I.; Bendicho, C.

    2010-01-01

    Inductively coupled plasma-mass spectrometry (ICP-MS) in combination with different supervised chemometric approaches has been used to classify cultivated mussels in Galicia (Northwest of Spain) under the European Protected Designation of Origin (PDO). 158 mussel samples, collected in the five rias on the basis of the production, along with minor and trace elements, including high field strength elements (HFSEs) and rare earth elements (REEs), were used with this aim. The classification of samples was achieved according to their origin: Galician vs. other regions (from Tarragona, Spain, and Ethang de Thau, France) and between the Galician Rias. The ability of linear discriminant analysis (LDA), soft independent modelling of class analogy (SIMCA) and artificial neural network (ANN) to classify the samples was investigated. Correct assignations for Galician and non-Galician samples were obtained when LDA and SIMCA were used. ANNs were more effective when a classification according to the ria of origin was to be applied.

  9. Classification of cultivated mussels from Galicia (Northwest Spain) with European Protected Designation of Origin using trace element fingerprint and chemometric analysis

    Energy Technology Data Exchange (ETDEWEB)

    Costas-Rodriguez, M.; Lavilla, I. [Departamento de Quimica Analitica y Alimentaria, Area de Quimica Analitica, Facultad de Quimica, Universidad de Vigo, As Lagoas-Marcosende s/n, 36310 Vigo (Spain); Bendicho, C., E-mail: bendicho@uvigo.es [Departamento de Quimica Analitica y Alimentaria, Area de Quimica Analitica, Facultad de Quimica, Universidad de Vigo, As Lagoas-Marcosende s/n, 36310 Vigo (Spain)

    2010-04-07

    Inductively coupled plasma-mass spectrometry (ICP-MS) in combination with different supervised chemometric approaches has been used to classify cultivated mussels in Galicia (Northwest of Spain) under the European Protected Designation of Origin (PDO). 158 mussel samples, collected in the five rias on the basis of the production, along with minor and trace elements, including high field strength elements (HFSEs) and rare earth elements (REEs), were used with this aim. The classification of samples was achieved according to their origin: Galician vs. other regions (from Tarragona, Spain, and Ethang de Thau, France) and between the Galician Rias. The ability of linear discriminant analysis (LDA), soft independent modelling of class analogy (SIMCA) and artificial neural network (ANN) to classify the samples was investigated. Correct assignations for Galician and non-Galician samples were obtained when LDA and SIMCA were used. ANNs were more effective when a classification according to the ria of origin was to be applied.

  10. Study of mineral and essential trace elements in milk and dairy products by inductively coupled plasma atomic emission spectrometry and neutron activation analysis

    International Nuclear Information System (INIS)

    Kira, Carmen Silvia

    2002-01-01

    The importance of food composition related to nutritional and toxicological contents has been emphasized in recent years. Some chemical elements are needed for cell metabolism, while excess or deficiency may be responsible for disorders. Milk is considered the most important food during the first months of life, nutritional needs of children being satisfied by milk and dairy products. These foods provide the main trace elements for the good growth of different tissues as well as the functioning of several enzymatic systems. Important deficiencies in mineral during this period can interfere with children's development. Determination of mineral and trace elements by using spectroscopic techniques generally involves a pretreatment of sample. Sample preparation is the most critical part of the analysis because of the long preparation time and the possibilities for contamination and losses of the analyte associated with this step. Different procedures of sample preparation (dry ashing digestion, wet digestion using an open focused microwave and a hot plate) were evaluated for determining Ca, Cr, Cu, Fe, K, Mg, Mn, Na, P and Zn in milk and dairy products by the ICP OES technique. In this work the concentrations obtained for the elements determined by the ICP OES technique after using the different treatments of sample were compared to the results obtained by the INAA technique, that does not require dissolution of sample. The partial digestion with diluted hydrochloric acid was found to be suitable for determining Ca, Cr, Cu, Fe, K, Mg, Mn, Na, P and Zn in milk samples and dairy products. (author)

  11. Determination of trace elements in scallop and fish otolith by instrumental neutron activation analysis using anti-coincidence and coincidence counting methods

    International Nuclear Information System (INIS)

    Suzuki, Shogo; Okada, Yukiko; Hirai, Shoji

    2005-01-01

    Trace element concentrations in scallop reference material and fish otolith certified reference materials prepared at the National Institute for Environmental Studies (NIES) of Japan were determined by instrumental neutron activation analysis (INAA). Nine aliquots of scallop sample (ca. 252∼507 mg) and five aliquots of fish otolith sample (ca. 502 ∼ 988 mg) and comparative standards were irradiated for a short time (10 s) at a thermal neutron flux of 1.5 x 10 12 n cm -2 s -1 (pneumatic transfer) and for a long time (6 h) at a thermal neutron flux of 3.7 x 10 12 n cm -2 s -1 (central thimble) in the Rikkyo University Research Reactor (100 kW). The irradiated samples were measured by conventional γ-ray spectrometry using a coaxial Ge detector, and by anti-coincidence and coincidence γ-ray spectrometry with a coaxial Ge detector and a well-type NaI (Tl) detector to determine as many trace elements as possible with high sensitivity. The concentrations of 34 elements of the NIES No.15 scallop reference material and 16 elements of the NIES No.22 fish otolith CRM were determined. Using the coincidence counting method to determine Se, Ba and Hf, the lower limit of the determination was improved by 2 times compared with the conventional counting method. (author)

  12. Trace element patterns in lichens following uranium mine closures

    International Nuclear Information System (INIS)

    Fahselt, D.; Wu, T.W.; Mott, B.

    1995-01-01

    Instrumental neutron activation analysis was used to determine trace elements in Cladina mitis (Sandst). Hale ampersand Culb. along transects extending from uranium mines at Elliot Lake and Agnew Lake in central Ontario, Canada. Levels of 11 elements were reported and the presence of uranium (U) was confirmed, although U concentrations were much less than in Cladina rangiferina 10 years earlier. Among the elements identified in lichen thalli was Th, which occurred in higher concentrations than U. All trace elements, including the two radionuclides, were found in deteriorating thallus parts as well as living podetia, and five of these seem to have originated as airborne particulates from minesites. In spite of mine closures, levels of Th and U remained higher near sources of ore dust and there was little relationship between radionuclide concentrations in thallus and substrate. 24 refs., 4 figs., 3 tabs

  13. Trace element determination study in human hair by neutron activation analysis; Estudo da determinacao de elementos traco em cabelos humanos pelo metodo de analise por ativacao com neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Frazao, Selma Violato

    2008-07-01

    Human hair analysis studies have been subject of continuous interest due to the fact that they can be used as an important tool to evaluate trace element levels in the human body. These determinations have been carried out to use hair for environmental and occupational monitoring, to identify intoxication or poisoning by toxic metals, to assess nutritional status, to diagnose and to prevent diseases and in forensic sciences. Although hair analysis presents several advantages over other human tissue or fluid analyses, such as organ tissue, blood, urine and saliva, there are some controversies regarding the use of hair analysis data. These controversies arise from the fact that it is difficult to establish reliable reference values for trace elements in hair. The purpose of this study was to evaluate the factors that affect element concentrations in hair samples from a population considered healthy and residing in the Sao Paulo metropolitan area. The collected human head hair was cut in small pieces, washed, dried and analyzed by neutron activation analysis (NAA). Aliquots of hair samples and synthetic elemental standards were irradiated at the IEA-R1 nuclear research reactor for 16 h under a thermal neutron flux of about 5x10{sup 12} n cm{sup -2} s{sup -1} for As, Br, Ca, Co, Cr, Cs, Cu, Fe, K, La, Na, Sb, Sc, Se and Zn determinations. The induced gamma activities of the standards and samples were measured using a gamma ray spectrometer coupled to an hiperpure Ge detector. For quality control of the results, IAEA- 85 Human Hair and INCT-TL-1 Tea Leaves certified reference materials (CRMs) were analyzed. Results obtained in these CRMs presented for most of elements, good agreement with the values of the certificates (relative errors less than 10%) and good precision (variation coefficients less than 13.6%). Results of replicate hair sample analysis showed good reproducibility indicating homogeneity of the prepared sample. Results obtained in the analyses of dyed and

  14. Analysis of trace elements in ceramic prints on automobile glasses for forensic examination using high-energy synchrotron radiation x-ray fluorescence spectrometry

    International Nuclear Information System (INIS)

    Nishiwaki, Yoshinori; Takatsu, Masahisa; Miyamoto, Naoki; Watanabe, Seiya; Shimoda, Osamu; Muratsu, Seiji; Nakanishi, Toshio; Nakai, Izumi

    2007-01-01

    This study revealed that high-energy SRXRF (synchrotron radiation X-ray fluorescence spectrometry) utilizing 75.5 keV X-rays of SPring-8 is a powerful technique for trace elemental analysis of ceramic prints on automotive glasses for forensic examination. Fragments of 99 ceramic prints were collected from automobiles of various manufacturers, types and model years. Their major heavy element-components were found to be either Pb or Bi. Because of recent environment protection movement for lead-free material, there was a tendency of the shift of material from the Pb Type to the Bi Type with years of the production. A utilization of 75.5 keV X-rays as excitation source allowed us to detect trace heavy-elements, such as Sb, La, Ce, Hf and W, as well as relatively light-elements, such as V, Cr, Mn, Fe, Co, Ni, Cu, Zn, Zr and Mo, in samples using K series of XRF emission lines. XRF intensities of these elements normalized by those of the major heavy-elements (Pb or Bi) became characteristic finger prints, showing the identity of each sample with a size of less than 0.5x0.5 mm 2 . The mean relative standard deviations of the normalized XRF intensities measured for the three fragments of each sample were less than 9.3%. These results show that the ceramic prints on automobile glasses contain rich elemental information for discrimination, and therefore the materials can be important evidence for practical forensic examinations. (author)

  15. Analysis of nutrients, selected inorganic constituents, and trace elements in water from Illinois community-supply wells, 1984-91

    Science.gov (United States)

    Warner, Kelly L.

    2000-01-01

    The lower Illinois River Basin (LIRB) study unit is part of the National Water-Quality Assessment program that includes studies of most major aquifer systems in the United States. Retrospective water-quality data from community-supply wells in the LIRB and in the rest of Illinois are grouped by aquifer and depth interval. Concentrations of selected chemical constituents in water samples from community-supply wells within the LIRB vary with aquifer and depth of well. Ranked data for 16 selected trace elements and nutrients are compared by aquifer, depth interval, and between the LIRB and the rest of Illinois using nonparametric statistical analyses. For all wells, median concentrations of nitrate and nitrite (as Nitrogen) are highest in water samples from the Quaternary aquifer at well depths less than 100 ft; ammonia concentrations (as Nitrogen), however, are highest in samples from well depths greater than 200 ft. Chloride and sulfate concentrations are higher in samples from the older bedrock aquifers. Arsenic, lead, sulfate, and zinc concentrations are appreciably different between samples from the LIRB and samples from the rest of Illinois for ground water from the Quaternary aquifer. Arsenic concentration is highest in the deep Quaternary aquifer. Chromium, cyanide, lead, and mercury are not frequently detected in water samples from community-supply wells in Illinois.

  16. Trace elements in natural drugs determined by INAA

    International Nuclear Information System (INIS)

    Chen Kehshaw; Tseng Chialiang; Lin Tehsien

    1993-01-01

    Natural drugs are widely used for diuretic, phlegm elimination and stomach invigoration purposes. Seventy-five of the most common remedies used by Chinese people have been subjected to trace element survey analysis by instrumental neutron activation. Within this large number of different natural products, fourteen trace elements (K, Sc, Cr, Fe, Co, Zn, Br, Rb, Cs, La, Sm, Eu, Au and Th) are commonly detected. Among these elements, Fe had the highest concentration followed by Zn, and Rb, Sm, Eu and Au were found to have the lowest concentrations. Although the three groups of natural drugs exhibit a widely different therapeutic action, the concentration ranges of the fourteen elements were very similar. While this suggests no apparent specific role for the trace elements in the drug function, parallels are drawn between the known drug related functions of Rb, Zn, Br, Fe, Co and K and the levels of elements found in the natural drugs. It is concluded that the various natural drugs also provide human benefits through supplements of essential elements such as Fe, Zn, Cr, Sc, Rb and Co. (author) 13 refs.; 5 tabs

  17. New Insights into Trace Element Partitioning in Amphibole from Multiple Regression Analysis, with Application to the Magma Plumbing System of Mt. Lamington (Papua New Guinea)

    Science.gov (United States)

    Zhang, J.; Humphreys, M.; Cooper, G.; Davidson, J.; Macpherson, C.

    2015-12-01

    We present a new multiple regression (MR) analysis of published amphibole-melt trace element partitioning data, with the aim of retrieving robust relationships between amphibole crystal-chemical compositions and trace element partition coefficients (D). We examined experimental data for calcic amphiboles of kaersutite, pargasite, tschermakite (Tsch), magnesiohornblende (MgHbl) and magnesiohastingsite (MgHst) compositions crystallized from basanitic-rhyolitic melts (n = 150). The MR analysis demonstrates the varying significance of amphibole major element components assigned to different crystallographic sites (T, M1-3, M4, A) as independent variables in controlling D, and it allows us to retrieve statistically significant relationships for REE, Y, Rb, Sr, Pb, Ti, Zr, Nb (n > 25, R2 > 0.6, p-value Ridolfi & Renzulli 2012) with lower Rb and Sr and higher Pb, relative to a hot, andesitic-dacitic melt (950-1,000±50 ºC; 60-70±5 wt % SiO2) where MgHst are crystallized. REE and Nb contents are similar in both types of melts despite higher REE and Nb in MgHbl-Tsch. Therefore, the REE compositional disparity between MgHst and MgHbl-Tsch is driven by the difference in the DREE, rather than the melt REE concentrations.

  18. Factor analytical approaches for evaluating groundwater trace element chemistry data

    International Nuclear Information System (INIS)

    Farnham, I.M.; Johannesson, K.H.; Singh, A.K.; Hodge, V.F.; Stetzenbach, K.J.

    2003-01-01

    The multivariate statistical techniques principal component analysis (PCA), Q-mode factor analysis (QFA), and correspondence analysis (CA) were applied to a dataset containing trace element concentrations in groundwater samples collected from a number of wells located downgradient from the potential nuclear waste repository at Yucca Mountain, Nevada. PCA results reflect the similarities in the concentrations of trace elements in the water samples resulting from different geochemical processes. QFA results reflect similarities in the trace element compositions, whereas CA reflects similarities in the trace elements that are dominant in the waters relative to all other groundwater samples included in the dataset. These differences are mainly due to the ways in which data are preprocessed by each of the three methods. The highly concentrated, and thus possibly more mature (i.e. older), groundwaters are separated from the more dilute waters using principal component 1 (PC 1). PC 2, as well as dimension 1 of the CA results, describe differences in the trace element chemistry of the groundwaters resulting from the different aquifer materials through which they have flowed. Groundwaters thought to be representative of those flowing through an aquifer composed dominantly of volcanic rocks are characterized by elevated concentrations of Li, Be, Ge, Rb, Cs, and Ba, whereas those associated with an aquifer dominated by carbonate rocks exhibit greater concentrations of Ti, Ni, Sr, Rh, and Bi. PC 3, and to a lesser extent dimension 2 of the CA results, show a strong monotonic relationship with the percentage of As(III) in the groundwater suggesting that these multivariate statistical results reflect, in a qualitative sense, the oxidizing/reducing conditions within the groundwater. Groundwaters that are relatively more reducing exhibit greater concentrations of Mn, Cs, Co, Ba, Rb, and Be, and those that are more oxidizing are characterized by greater concentrations of V, Cr, Ga

  19. Toxic trace element assessment for soils/sediments deposited during Hurricanes Katrina and Rita from southern Louisiana, USA: a sequential extraction analysis.

    Science.gov (United States)

    Shi, Honglan; Witt, Emitt C; Shu, Shi; Su, Tingzhi; Wang, Jianmin; Adams, Craig

    2010-07-01

    Analysis of soil/sediment samples collected in the southern Louisiana, USA, region three weeks after Hurricanes Katrina and Rita passed was performed using sequential extraction procedures to determine the origin, mode of occurrence, biological availability, mobilization, and transport of trace elements in the environment. Five fractions: exchangeable, bound to carbonates, bound to iron (Fe)-manganese (Mn) oxides, bound to organic matter, and residual, were subsequently extracted. The toxic trace elements Pb, As, V, Cr, Cu, and Cd were analyzed in each fraction, together with Fe in 51 soil/sediment samples. Results indicated that Pb and As were at relatively high concentrations in many of the soil/sediment samples. Because the forms in which Pb and As are present tend to be highly mobile under naturally occurring environmental conditions, these two compounds pose an increased health concern.Vanadium and Cr were mostly associated with the crystal line nonmobile residual fraction. A large portion of the Cu was associated with organic matter and residual fraction. Cadmium concentrations were low in all soil/sediment samples analyzed and most of this element tended to be associated with the mobile fractions. An average of 21% of the Fe was found in the Fe-Mn oxide fraction, indicating that a substantial part of the Fe was in an oxidized form. The significance of the overall finding of the present study indicated that the high concentrations and high availabilities of the potentially toxic trace elements As and Pb may impact the environment and human health in southern Louisiana and, in particular, the New Orleans area. Copyright (c) 2010 SETAC.

  20. Determination of trace elements in small water samples by total reflexion X-ray fluorescence (TXRF) and by neutron activation analysis (NAA)

    Energy Technology Data Exchange (ETDEWEB)

    Lieser, K.H. (Fachbereich Chemie, Eduard Zintl-Inst., Technische Hochschule Darmstadt (Germany)); Flakowski, M. (Fachbereich Chemie, Eduard Zintl-Inst., Technische Hochschule Darmstadt (Germany)); Hoffmann, P. (Fachbereich Chemie, Eduard Zintl-Inst., Technische Hochschule Darmstadt (Germany))

    1994-09-01

    The problems encountered in the determination of trace elements in small sample volumes of the order of 1 to 10 [mu]l (e.g. in droplets of water) are discussed. Total reflexion X-ray fluorescence (TXRF) and neutron activation analysis (NAA) are applied for the determination of Na, Mg, K, Ca, Mn, Fe, Co, and Cu in concentrations of 0.01 to 10 mg/L in 1 to 10 [mu]L of water. The applied methods are described, the results are discussed and the advantages of TXRF are brought forward. (orig.)

  1. Determination of trace elements in Brazilian rice grains and in biological reference materials by neutron activation analysis

    International Nuclear Information System (INIS)

    Maihara, V.A.; Vasconcellos, M.B.A.

    1989-01-01

    Instrumental neutron activation analysis was applied to the determination of the elements Na, K, Br, As, Rb, Zn, Co, Fe and Sc in Brazilian rice samples and in biological standards. Hg and Se concentrations were determined by using a simple radiochemical separation. The chemical procedure was carried out by means of distillation of Hg and Se in HBr medium and subsequent precipitation of selenium by sodium methabissulfide and mercury by thioacetamide. The accuracy of the instrumental and radiochemical methods was evaluated by means of analysis of the Reference Materials NBS-Bovine Liver, Bowen's Kale and NBS-Rice Flour. (author) [pt

  2. Vapor phase treatment–total reflection X-ray fluorescence for trace elemental analysis of silicon wafer surface

    Energy Technology Data Exchange (ETDEWEB)

    Takahara, Hikari, E-mail: hikari@rigaku.co.jp [Rigaku Corp., 14-8 Akaoji-cho, Takatsuki, Osaka 569-1146 (Japan); Mori, Yoshihiro [Horiba Ltd., 2 Miyanohigashi, Kisshoin, Minami-ku, Kyoto 601-8510 (Japan); Shibata, Harumi [SUMCO Corporation, Seavance North, 1-2-1 Shibaura, Minato-ku, Tokyo 105-8634 (Japan); Shimazaki, Ayako [Toshiba Corporation, 8, Shinsugita-cho, Isogo-ku, Yokohama 235-8522 (Japan); Shabani, Mohammad B. [Mitsubishi Material Corporation, 1-297, Kitabukuro-cho, Omiya-ku, Saitama 330-8508 (Japan); Yamagami, Motoyuki [Rigaku Corp., 14-8 Akaoji-cho, Takatsuki, Osaka 569-1146 (Japan); Yabumoto, Norikuni [Analysis Atelier Co., 4-36-4, Yoyogi, Shibuya-ku, Tokyo 151-0053 (Japan); Nishihagi, Kazuo [Horiba Ltd., 2 Miyanohigashi, Kisshoin, Minami-ku, Kyoto 601-8510 (Japan); Gohshi, Yohichi [Tsukuba University, 1-1-1, Tennodai, Tsukuba, Ibaraki 305-8571 (Japan)

    2013-12-01

    Vapor phase treatment (VPT) was under investigation by the International Organization for Standardization/Technical Committee 201/Working Group 2 (ISO/TC201/WG2) to improve the detection limit of total reflection X-ray fluorescence spectroscopy (TXRF) for trace metal analysis of silicon wafers. Round robin test results have confirmed that TXRF intensity increased by VPT for intentional contamination with 5 × 10{sup 9} and 5 × 10{sup 10} atoms/cm{sup 2} Fe and Ni. The magnification of intensity enhancement varied greatly (1.2–4.7 in VPT factor) among the participating laboratories, though reproducible results could be obtained for average of mapping measurement. SEM observation results showed that various features, sizes, and surface densities of particles formed on the wafer after VPT. The particle morphology seems to have some impact on the VPT efficiency. High resolution SEM observation revealed that a certain number of dots with SiO{sub 2}, silicate and/or carbon gathered to form a particle and heavy metals, Ni and Fe in this study were segregated on it. The amount and shape of the residue should be important to control VPT factor. - Highlights: • This paper presents a summary of study results of VPT–TXRF using ISO/TC201/WG2. • Our goal is to analyze the trace metallic contamination on silicon wafer with concentrations below 1 × 10{sup 10} atoms/cm{sup 2}. • The efficiency and mechanism of VPT are discussed under several round robin tests and systematic studies.

  3. Bioaccumulation of trace elements by Avicennia marina

    Directory of Open Access Journals (Sweden)

    Kandasamy Kathiresan

    2014-11-01

    Full Text Available Objective: To analyze the concentrations of 12 micro-nutrients (Al, B, Cd, Co, Cr, Cu, Fe, Mg, Mn, Ni, Pb, and Zn in different plant parts of Avicennia marina and its rhizosphere soil of the south east coast of India. Methods: The samples were acid digested, then analyzed by using inductively coupled plasma system (ICP-Optical Emission Spectrophotometer. Results: Levels of metals were found in the decreasing order: Cd>Co>Ni>Pb>B >Cr>Zn>Mg>Mn>Cu>Fe>Al. The soil held more levels of metals than plant parts, but within the permissible limits of concentration. Bark and root accumulated higher levels of trace elements in a magnitude of 10-80 folds than other plant parts. The overall bioaccumulation factor in the sampling sites of Vellar, Pichavaram and Cuddalore was 2.88, 1.42 0.47 respectively. Essential elements accumulate high in mature mangroves forest while non-essential elements accumulate high in the industrially polluted mangroves. Conclusions: The ratio between essential and non-essential elements was found higher in young mangrove forest than that in mature mangrove forest and polluted mangrove areas. Thus, the ratio of accumulation can be used as an index of the growth and pollution status of mangroves.

  4. A preliminary analysis of trace-elemental signatures in statoliths of different spawning cohorts for Dosidicus gigas off EEZ waters of Chile

    Science.gov (United States)

    Liu, Bilin; Chen, Xinjun; Fang, Zhou; Hu, Song; Song, Qian

    2015-12-01

    We applied solution-based ICP-MS method to quantify the trace-elemental signatures in statoliths of jumbo flying squid, Dosidius gigas, which were collected from the waters off northern and central Chile during the scientific surveys carried out by Chinese squid jigging vessels in 2007 and 2008. The age and spawning date of the squid were back-calculated based on daily increments in statoliths. Eight elemental ratios (Sr/Ca, Ba/Ca, Mg/Ca, Mn/Ca, Na/Ca, Fe/Ca, Cu/Ca and Zn/Ca) were analyzed. It was found that Sr is the second most abundant element next to Ca, followed by Na, Fe, Mg, Zn, Cu, Ba and Mn. There was no significant relationship between element/Ca and sea surface temperature (SST) and sea surface salinity (SSS), although weak negative or positive tendency was found. MANOVA analysis showed that multivariate elemental signatures did not differ among the cohorts spawned in spring, autumn and winter, and no significant difference was found between the northern and central sampling locations. Classification results showed that all individuals of each spawned cohorts were correctly classified. This study demonstrates that the elemental signatures in D. gigas statoliths are potentially a useful tool to improve our understanding of its population structure and habitat environment.

  5. Determination of some of the trace elements in bark by neutron activation analysis and high-resolution spectroscopy

    International Nuclear Information System (INIS)

    Hattula, T.; Johanson, M.

    1978-01-01

    Thermal neutron activation analysis, effected with a high resolution Ge(Li)-gamma spectrometer, has been applied for determination of the content of Na, K, Mn, Zn, Co, Sb, Ba, Cr, Sc, and Au in bark from birch (Betula pubescens), pine (Pinus silvestris), and spruce (Picea abies). The samples were taken from the bark of a newly-cut tree, from bark which has been stored on the shore, and from bark which had been kept in the ''dirty'' water of the storage pool for mill-wood for varying lengths of time. No technique of radiochemical separation was employed. This method thus eliminates many of the inherent errors associated with chemical determinations. A check was made of the homogeneity of the samples by determining three elements in the different layers of birch bark. The reproducibility of the determinations was checked by making six parallel determinations of five elements in a sample of pine bark made as homogeneous as possible. (author)

  6. Trace elements in the atmosphere over South Africa

    International Nuclear Information System (INIS)

    Wells, R.B.; Van As, D.

    1976-01-01

    Natural sources of trace elements in the atmosphere are suspended soil particles, the evaporation of sea spray and smoke from veld fires. In urban and industrialised areas the main sources are fossil-fuel power plants, metallurgical smelters, blast furnaces, incinerators, automobiles, fossil-fueled locomotives and open fires in the Black townships. Often a source can be recognised by the relative concentrations of particular trace elements. A monitoring programme was established in 1974 by the Air Pollution Research Group of the CSIR and the Isotope and Radiation Division of the Atomic Energy Board in order to study the levels of trace elements in urban areas such as Johannesburg, Cape Town, and Durban, to measure the effects of industrialisation on trace elements levels in developing areas such as Richards Bay and Saldanha Bay and also to determine baseline values in rural areas. Extremely sensitive analytical techniques, e.g. neutron activation and atomic absorption were used for the analyses of filter samples. Methods of sampling and analysis are discussed and the preliminary results of this programme are presented

  7. The content of minerals and trace elements in meals

    International Nuclear Information System (INIS)

    Bognar, A.; Schelenz, R.; Gruenewald, T.; Frahm, H.; Heine, K.; Wiechen, A.; Bundesanstalt fuer Milchforschung, Kiel

    1981-07-01

    Within the frame work of the research programme 'School Feeding', 68 menu items of different producers were investigated for the content of the minerals calcium, chlorine, iron, potassium, magnesium, sodium and phosphorus, and for the trace elements antimony, barium, bromine, cesium, chromium, hafnium, iridium,cobalt, copper, manganese, mercury, rubidium, scandium, selenium, silver, strontium, tin and zinc. For the analytical determination of the elements, instrumental neutron activation analysis and X-ray fluorometry were applied. The studies showed that a calculation of the content of minerals and trace elements in meals on the basis of recipes and nutritive tables for raw foods is not justified, expect for sodium and phosphorus, because incorrect results can be obtained for the majority of meals. (orig./MG) [de

  8. Compton suppression instrumental neutron activation analysis performance in determining trace- and minor-element contents in foodstuff

    International Nuclear Information System (INIS)

    Freitas, M.C.; Dionisio, I.; Pacheco, A.M.G.; Bacchi, M.A.; Fernandes, E.A.N.; Landsberger, S.; Braisted, J.

    2008-01-01

    In 2003-2004, several food items were purchased from large commercial outlets in Coimbra, Portugal. Such items included meats (chicken, pork, beef), eggs, rice, beans and vegetables (tomato, carrot, potato, cabbage, broccoli, lettuce). Elemental analysis was carried out through INAA at the Technological and Nuclear Institute (ITN, Portugal), the Nuclear Energy Centre for Agriculture (CENA, Brazil), and the Nuclear Engineering Teaching Lab of the University of Texas at Austin (NETL, USA). At the latter two, INAA was also associated to Compton suppression. It can be concluded that by applying Compton suppression (1) the detection limits for arsenic, copper and potassium improved; (2) the counting-statistics error for molybdenum diminished; and (3) the long-lived zinc had its 1115-keV photopeak better defined. In general, the improvement sought by introducing Compton suppression in foodstuff analysis was not significant. Lettuce, cabbage and chicken (liver, stomach, heart) are the richest diets in terms of human nutrients. (author)

  9. Determination of minor, trace and toxic elements in chewing tobacco products by instrumental neutron activation analysis and identification of glutamic acid

    International Nuclear Information System (INIS)

    Garg, A.N.; Paul Choudhury, R.; Acharya, R.; Reddy, A.V.R.

    2012-01-01

    Tobacco smoking/chewing has been a cause of concern because of it being related with oral cancer. It causes stimulation and ill physiological effects. Ten different brands of spit tobacco, eight gutkaas and five paan masalas have been analyzed for seven minor (Al, Na, K, Ca, Cl, Mg, and P) and 17 trace (As, Ba, Br, Co, Cr, Cs, Cu, Eu, Fe, Hg, La, Mn, Rb, Sb, Sc, Th, and Zn) elements by instrumental neutron activation analysis. Also Ni and Pb were determined by atomic absorption spectrophotometry. Concentration of Cd was below detection limit ( -1 ) in the tobacco samples. Mg, generally added as MgCO 3 to prevent caking, is present as minor constituent in spit tobacco and gutkaas but is below detection limit ( -1 ) in paan masalas. Most elemental concentrations vary in a wide range depending on the nature of chewing tobacco. Spit tobacco has been found to be more enriched in essential elements (Ca, K, Na, P, Mn, and Rb), whereas gutkaas contain higher concentrations of Fe, Cr, Cu, and Zn. Paan masalas contain lower contents of other elements but higher content of Hg. Gutkaas also contain higher amounts of As and Pb. Further glutamic acid has been separated from tobacco leaves and characterized as it might bind with some elements. (author)

  10. Study of trace elements distribution in various tissues structures

    International Nuclear Information System (INIS)

    Kwiatek, W.M.; Marczewska, E.

    1994-01-01

    Many papers have been written during the past ten years about TE study in cancer and normal tissues describing the use of different methods for detection of trace elements. Concentration of TE depends strongly on the sample measured. However, according to our knowledge, the role of TE in cancerous tissue is still known. Therefore, we propose to perform an experiment which will hopefully given us more information about the relationship between the concentration of elements in different tissues. The developing industry localised near Cracow becomes a serious danger for health of it's inhabitants. The negative influence of the air pollution to the living organisms is seen not only in the nature but also in humans. Therefore we want to analyse the trace element contents in the air. Such investigation will give the information about the pollution level in the City. The pollution has its obvious negative influence to health and toxic element concentration level in blood. It is interesting to check if placenta plays an effective role in foetus protection against toxic metals. In order to study this problem, the trace element analysis of placenta tissues will be done by means of synchrotron microbeam. (author). 1 ref

  11. Trace elements in human seminal plasma and spermatozoa.

    Science.gov (United States)

    Pleban, P A; Mei, D S

    1983-09-15

    Methodologies for the analysis of cadmium, copper, iron, lead, selenium and zinc in human seminal plasma and spermatozoa have been developed. Analyses were made directly in a dilution of seminal plasma or nitric acid digest of lyophilized cells using Zeeman-effect atomic absorption spectroscopy. Within-run coefficients of variation (CV's) for pooled specimens ranged from 0.5% to 9%. Between-run CV's ranged from 4% to 13%. Analysis of a seminal plasma specimen at 1/2, 1, 1 1/2, 3 1/2 and 5 hours post emission indicated that no change in seminal plasma trace element concentrations occurred on standing in contact with spermatozoa. Trace element concentrations were determined in specimens from patients undergoing infertility studies.

  12. A study on monitoring methodology for trace elements in the environment through chemical analysis of hair. Part of a coordinated programme on nuclear methods in health-related monitoring of trace element pollutants

    International Nuclear Information System (INIS)

    Fukushima, I.

    1981-06-01

    An attempt was made to monitor community exposure to environmental As, Cd, Cr, Hg, Mn, Pb and Se using hair analysis by instrumental neutron activation analysis and atomic absorption spectroscopy. Hair samples were collected from male and female subjects from six Japanese localities. Samples from each locality were respectively mixed and analysed for elements of interest. The results indicated that this approach was effective in revealing geographical differences of hair elemental levels. The method is suitable for a routine monitoring programme of community exposure to environmental metal pollutants

  13. Thermal neutron activation analysis of essential and trace elements and organic constituents in Trikatu. An Ayurvedic formulation

    International Nuclear Information System (INIS)

    Choudhury, R.P.; Kumar, A.; Garg, A.N.; Reddy, A.V.R.

    2007-01-01

    Trikatu, an Ayurvedic formulation of three dried powder spices, ginger, black pepper and pipali in equal proportion is widely used to promote digestion, assimilation and bioavailibility of food. It works synergistically, and hence, is more effective than an equal amount of any of its three ingredients taken separately. Five different brands and its three constituents were analyzed for 31 elements by instrumental neutron activation analysis (INAA) using 5-minute and 6-hour thermal neutron irradiation followed by high-resolution γ-ray spectrometry. Heavy toxic metals Cd, Ni and Pb determined by atomic absorption spectrometry (AAS) were found below permissible limits. Most elements in different brands vary in a narrow range. Ginger is particularly enriched in Ca, Fe, Mg and Mn whereas black pepper is enriched in Cr, Se, P and Zn. Cu/Zn shows linear relationship (r = 0.92) with Cu whereas Fe and Mn exhibit inverse correlation (r = -0.89) in different brands. Hydro distillation of pipali yielded an essential oil whereby 10 organic constituents were identified by GC-MS. Also barbituric and tannic acids were isolated from the aqueous methanolic extract of pipali. (author)

  14. Particle size gradation of trace elements in river water

    Energy Technology Data Exchange (ETDEWEB)

    Tanizaki, Yoshiyuki; Yamazaki, Masao; Nagatsuka, Sumiko (Tokyo Metropolitan Isotope Research Center (Japan))

    1983-09-01

    It is important to know the physical and chemical existence form of trace elements for understanding the origins, physical behavior, chemical behavior and the concentration of harmful elements in aquatic organisms. But, it is difficult to analyze many kinds of elements directly. The determination of chemical species from physical state through the distribution of particle size is effective. Filtration method is most simple, and is possible to handle large amount of sample water. The existing states of about 30 elements were made clear by the application of filtration and radioactivation analysis. The specimens of river water were collected at Hamura, the upper stream of the Tama River, and at Inagi, the middle of the same river. The specimens were divided into 9 portions using 8 steps of milli-pore filters. Suspension, colloid and solution are the state of elements. As the results of consideration, the distributions of elements were divided into three patterns in accordance with their states of existence in water. The tendency of the distributions of elements in water was made clear as follows. Alkali metals, alkali earth metals and the elements of high valency were present in the state of solution, and transition elements and rare earth elements were present as suspension. Further studies on the effects of organic substances on the solubility of transition elements are scheduled.

  15. Developments and trends in inductively coupled plasma mass spectrometry and its influence on the recent advances in trace element analysis

    International Nuclear Information System (INIS)

    Balaram, V.

    1995-01-01

    A brief introduction to the various instrumental methods such as atomic absorption spectrometry, x-ray fluorescence spectrometry, neutron activation analysis, inductively coupled plasma atomic emission spectrometry, thermal ionization mass spectrometry, etc. are presented highlighting their relative merits and demerits. The history and developments of inductively coupled plasma mass spectrometry (ICP-MS) and its advantages and limitations over other multi-element instrumental techniques are reviewed. Extended capabilities by hyphenating ICP-MS to various other well-known sample introduction techniques such as flow-injection, electrothermal vaporization, chromatographic methods and laser ablation are discussed in brief. The recent development of high resolution multi-collector double-focusing magnetic mass spectrometer with inductively coupled plasma at atmospheric pressure as source is also discussed. Some of the areas where more developments can be expected in future are suggested. (author). 77 refs., 4 tabs., 3 figs

  16. Nuclear analytical methods for trace element studies in calcified tissues

    International Nuclear Information System (INIS)

    Chaudhry, M.A.; Chaudhry, M.N.

    2001-01-01

    Full text: Various nuclear analytical methods have been developed and applied to determine the elemental composition of calcified tissues (teeth and bones). Fluorine was determined by prompt gamma activation analysis through the 19 F(p,ag) 16 O reaction. Carbon was measured by activation analysis with He-3 ions, and the technique of Proton-Induced X-ray Emission (PIXE) was applied to simultaneously determine Ca, P, and trace elements in well-documented teeth. Dental hard tissues, enamel, dentine, cement, and their junctions, as well as different parts of the same tissue, were examined separately. Furthermore, using a Proton Microprobe, we measured the surface distribution of F and other elements on and around carious lesions on the enamel. The depth profiles of F, and other elements, were also measured right up to the amelodentin junction

  17. Synchrotron radiation TXRF and EDXRS on AP1 foils applied to the analysis of trace elements in metal alloys: a comparison

    International Nuclear Information System (INIS)

    Wobrauschek, P.; Pepponi, G.; Streli, C.; Zoeger, N.; Jokubonis, C.; Hegedues, F.; Falkenberg, G.

    2000-01-01

    Synchrotron radiation induced TXRF and conventional 45 o EDXRF using a film 150 nm thick have been exploited for the elemental analysis of traces in alloys used for the construction of reactor pressure vessels of nuclear power plants. The methods used achieve a very low background due to the total reflection phenomenon and the thin sample support. Synchrotron radiation was needed since there are no laboratory sources which can deliver a collimated beam of the energy needed to excite the K-shell of the Rare Earth Elements, allowing the achievement of minimum detection limits relevant for the proposed purpose (pg/g range). Moreover the linear polarization of synchrotron radiation combined with a side-looking detection manages to reduce the scattering due to the remaining matrix contained in the analyzed samples. Lowest detection limits for Nb and for some of the rare earth elements obtained with the two techniques are presented and the two approaches compared. Experiments have been carried out at Hasylab beamline L (bending magnet). For the TXRF experiments the beamline was equipped with a double reflector collimator, which acts as a collimator also as a high energy cut-off, and a multilayer for the monochromatization of the beam. For the measurements in the standard 45 o geometry the microfluorescence facility installed at the beamline was used. Chemical preparation of the sample included dissolution and separation by means of ionic exchange chromatography. Detection of traces of Niobium allows a retrospective fast neutron flux determination on nuclear reactor pressure vessels. Thus an indirect monitoring of the status of the vessel can be done analyzing small quantities of steel taken from the inner surface of the pressure vessel. Both the techniques are well suited to the analysis since they require a low amount of sample, important on one hand because of the limited disposal and on the other because of its high specific activity. Of interest is also the

  18. Risk of human exposure to arsenic and other toxic elements from geophagy: trace element analysis of baked clay using inductively coupled plasma mass spectrometry

    Directory of Open Access Journals (Sweden)

    Watts Michael J

    2010-12-01

    Full Text Available Abstract Background Geophagy or earth-eating is common amongst some Bangladeshi women, especially those who are pregnant, both in Bangladesh and in the United Kingdom. A large proportion of the population in Bangladesh is already exposed to high concentrations of arsenic (As and other toxic elements from drinking contaminated groundwater. Additional exposure to As and other toxic elements from non-food sources has not been adequately addressed and here we present the first study to monitor As levels in baked clay (known as sikor. Methods Sikor samples originating from Bangladesh were digested using a microwave digester and analysed for their As, Pb, Cd, Mn, Fe and Zn levels using ICP-MS. Detailed As speciation analysis was performed using HPLC-ICP-MS. Results Of particular concern were the levels of As (3.8-13.1 mg kg-1, Cd (0.09-0.4 mg kg-1 and Pb (21-26.7 mg kg-1 present in the sikor samples and their possible impact on human health. Speciation analysis revealed that sikor samples contained mainly inorganic As. Modest consumption of 50 g of sikor is equivalent to ingesting 370 μg of As and 1235 μg of Pb per day, based on median concentration values. This level of sikor consumption exceeds the permitted maximum tolerable daily intake (PMTDI of inorganic As by almost 2-fold. Conclusion We conclude that sikor can be a significant source of As, Cd and Pb exposure for the Bangladeshi population consuming large quantities of this material. Of particular concern in this regard is geophagy practiced by pregnant women concurrently exposed to As contaminated drinking water. Future studies needs to evaluate the bioavailability of As and other elements from sikor and their impact on human health.

  19. Trace Element Analysis of Minerals in Magmatic-Hydrothermal Ores by Laser Ablation Inductively-Coupled Plasma Mass Spectrometry: Approaches and Opportunities

    Directory of Open Access Journals (Sweden)

    Nigel Cook

    2016-10-01

    Full Text Available Laser ablation inductively-coupled plasma mass spectrometry (LA-ICP-MS has rapidly established itself as the method of choice for generation of multi-element datasets for specific minerals, with broad applications in Earth science. Variation in absolute concentrations of different trace elements within common, widely distributed phases, such as pyrite, iron-oxides (magnetite and hematite, and key accessory minerals, such as apatite and titanite, can be particularly valuable for understanding processes of ore formation, and when trace element distributions vary systematically within a mineral system, for a vector approach in mineral exploration. LA-ICP-MS trace element data can assist in element deportment and geometallurgical studies, providing proof of which minerals host key elements of economic relevance, or elements that are deleterious to various metallurgical processes. This contribution reviews recent advances in LA-ICP-MS methodology, reference standards, the application of the method to new mineral matrices, outstanding analytical uncertainties that impact on the quality and usefulness of trace element data, and future applications of the technique. We illustrate how data interpretation is highly dependent on an adequate understanding of prevailing mineral textures, geological history, and in some cases, crystal structure.

  20. Analysis of bioaccessible concentration of trace elements in plant based edible materials by INAA and ICPMS methods

    International Nuclear Information System (INIS)

    Dutta, R.K.; Maharia, R.S.; Acharya, R.; Reddy, A.V.R.

    2014-01-01

    The total metal concentration and bioaccessible concentration of Cr, Mn, Fe, Cu, Zn, Se in Momordica charantia, Asparagus racemosus, Terminalia arjuna and Syzyzium cumini were measured by instrumental neutron activation analysis and by inductively coupled plasma mass spectrometry analysis (ICP-MS). The bioaccessible concentrations were determined in the gastrointestinal digest obtained after treating dried powdered samples sequentially in gastric and intestinal fluid of porcine origin at physiological conditions. The bioaccessible concentration of Fe was in the range of 58-67 mg kg -1 , Mn was 10.2-14.6 mg kg -1 , Cu was 3.7-4.8 mg kg -1 and Zn was 10.6-18.4 mg kg -1 , were within the safety limits set for vegetable food stuff set by Joint FAO/WHO. The bioaccessibility of Zn, an essential element, was high (40-50 %) in M. charantia and in S. cumini. In addition, the total metal contents and bioaccessible concentration of Ni, Se, Cd and Pb in these samples were measured by ICP-MS. The total Cd content in S. cumini (2.6 ± 0.2 mg kg -1 ) and its bioaccessible concentration (0.6 mg kg -1 ) were strikingly high as compared to the other samples. Though total Hg contents were determined by ICP-MS, but their bioaccessible concentrations were below the detection limit (0.036 mg kg -1 ). (author)

  1. Role of trace elements in animals: a review

    Directory of Open Access Journals (Sweden)

    Mohd Iqbal Yatoo

    2013-12-01

    Full Text Available Trace elements, though required in minute quantities (less than 100 mg/kg dry matter, are essential for maintaining health andimmunity. They are involved in growth, production and reproduction. Trace elements act as cofactors of enzymes which areimportant to the immunity of animal. Superoxide dismutase , glutathione reductase, glutathione peroxidase, thioredoxinreductase, ceruloplasmin and catalase are important enzymes that have trace elements as cofactors. These enzymes act asantioxidants and prevent oxidative stress by neutralizing oxidants produced under different stresses. Besides, trace elementscontribute to general health of animal thereby enhancing disease resistance. Trace elements are important for properfunctioning of a number of enzymes and proteins which are involved in many physiological, biochemical and metabolicprocesses that contribute to growth and production. Overall, trace elements improve immune competence and productiveperformance.

  2. Trace analysis of semiconductor materials

    CERN Document Server

    Cali, J Paul; Gordon, L

    1964-01-01

    Trace Analysis of Semiconductor Materials is a guidebook concerned with procedures of ultra-trace analysis. This book discusses six distinct techniques of trace analysis. These techniques are the most common and can be applied to various problems compared to other methods. Each of the four chapters basically includes an introduction to the principles and general statements. The theoretical basis for the technique involved is then briefly discussed. Practical applications of the techniques and the different instrumentations are explained. Then, the applications to trace analysis as pertaining

  3. Hyperaccumulators of metal and metalloid trace elements: facts and fiction.

    NARCIS (Netherlands)

    van der Ent, A.; Baker, A.J.M.; Reeves, R.D.; Pollard, A.J.; Schat, H.

    2012-01-01

    Background: Plants that accumulate metal and metalloid trace elements to extraordinarily high concentrations in their living biomass have inspired much research worldwide during the last decades. Hyperaccumulators have been recorded and experimentally confirmed for elements such as nickel, zinc,

  4. Canned foods: appropriate in trace element studies?

    Science.gov (United States)

    Henriksen, L K; Mahalko, J R; Johnson, L K

    1985-05-01

    This study was conducted to help decrease the variability of metabolic diets. The effects of production lot and storage time on the trace element content of canned food products were compared. Various production lots of peaches, green beans, and tomatoes, canned in tinplate, were purchased and opened at three different times, spaced at 6-month periods. Storage time contributed more to the variability of tomatoes and green beans than production lot. Production lot was the more important factor in peaches. The following guidelines may be useful for metabolic studies lasting more than a few weeks: Use only frozen foods or foods canned in glass, maintaining constant production lots when possible. If only tin-canned products are available, remove the product from the can and freeze when appropriate. When products are retained in the can, maintain storeroom at a low temperature above freezing. In all cases, purchase specifications should require products to be from the most recent canning season, and kitchen procedures should be constant.

  5. Analysis of nutrition-relevant trace elements in human blood and serum by means of total reflection X-ray fluorescence (TXRF) spectroscopy

    International Nuclear Information System (INIS)

    Stosnach, Hagen; Mages, Margarete

    2009-01-01

    In clinical service laboratories, one of the most common analytical tasks with regard to inorganic traces is the determination of the nutrition-relevant elements Fe, Cu, Zn, and Se. Because of the high numbers of samples and the commercial character of these analyses, a time-consuming sample preparation must be avoided. In this presentation, the results of total reflection X-ray fluorescence measurements with a low-power system and different sample preparation procedures are compared with those derived from analysis with common methods like Atomic Absorption Spectroscopy (AAS) and Inductively Coupled Plasma Mass Spectroscopy (ICP-MS). The results of these investigations indicate that the optimal total reflection X-ray fluorescence analysis of the nutrition-relevant elements Fe, Cu, Zn, and Se can be performed by preparing whole blood and serum samples after dilution with ultrapure water and transferring 10 μl of internally standardized sample to an unsiliconized quartz glass sample carrier with subsequent drying in a laboratory oven. Suitable measurement time was found to be 600 s. The enhanced sample preparation by means of microwave or open digestion, in parts combined with cold plasma ashing, led to an improvement of detection limits by a factor of 2 for serum samples while for whole blood samples an improvement was only observed for samples prepared by means of microwave digestion. As the matrix elements P, S, Cl, and for whole blood Fe have a major influence on the detection limits, most probably a further enhancement of analytical quality requires the removal of the organic matrix. However, for the routine analysis of the nutrition-relevant elements, the dilution preparation was found to be sufficient.

  6. Determination of elemental concentrations at trace levels in alumina by charged particle activation analysis using proton beam from VEC accelerator

    International Nuclear Information System (INIS)

    Datta, J.; Dasgupta, S.; Chowdhury, D.P.; Verma, R.

    2015-01-01

    The elemental impurities have been determined in high purity alumina material used in nuclear reactors at ppb (μg kg -1 ) to ppm (mg kg -1 ) levels by CPAA using proton beam from VEC machine. Proton beam has the advantage of high cross section for (p, n) reaction to produce suitable nuclide for activation analysis by instrumental approach. The cross sections of higher reaction channels like (p, 2n), (p, pn) are found to be less than 1 mb below 13 MeV proton by theoretical calculation using ALICE 91 computer code. Therefore, 13 MeV proton beam was used to irradiate the alumina samples along with standards, Lake (IAEA-SL -1 ) and Marine (PACS-2) sediments, both in pellet and powder forms. The irradiation was carried out with 50 nA to 1μA beam current for 10 min to 10 h depending on types of samples and standards. The beam current was measured by Faraday cup and also checked by putting Ti monitoring foil before the target. Ni is determined by (p, pn) reaction using 18 MeV proton as there is no suitable product from (p, n) reaction. The counting measurements of irradiated samples were performed with a high resolution γ-spectrometer using HPGe detector (relative efficiency - 40%, resolution - 2.0 keV at 1332 keV) coupled to a PC based 8 k MCA. The validation of the CPAA results has been carried out by INAA with the same alumina samples, carried out in Dhruva reactor with neutron flux 10 14 cm 2 s -1 using standards IAEA-SL-1 and PACS-2

  7. Trace element fingerprinting of emeralds by PIXE/PIGE

    International Nuclear Information System (INIS)

    Ma Xinpei; MacArthur, J.D.; Roeder, P.L.; Mariano, A.N.

    1993-01-01

    Gemologists consider the mineral beryl, beryllium aluminium silicate, to be the gem, emerald, when it contains sufficient chromium, >0.1%, to colour it a strong green. Emeralds usually contain other trace elements. To investigate the feasibility of distinguishing an emerald's country of origin through its trace content, the trace elements in emeralds and a few beryls from sixteen locations have been determined with a single nondestructive measurement using PIXE and PIGE. From the database established with this limited number of samples, distinguishing trace element patterns were found. (orig.)

  8. Late Pliensbachian-early Toarcian paleoenvironmental changes in the Cleveland Basin: new clues from high-resolution trace element analysis

    DEFF Research Database (Denmark)

    Thibault, Nicolas Rudolph; Ruhl, Micha; Ullmann, Clemens Vinzenz

    elements across the late Pliensbachian to middle Toarcian of the Cleveland Basin. The Pl/To boundary CIE is associated with low Total Organic Carbon (TOC... on the behaviour of elements associated with organic matter and the sulphur cycle such as Ni, Cu, Zn and As. Cu is well-correlated to the TOC whereas As shows an enrichment in the interval of black shale deposition after the CIE and two distinct correlation lines with sulphur, one before and during the event...

  9. Distribution of trace elements in moss biomonitors near Mumbai

    International Nuclear Information System (INIS)

    Chakrabortty, S.; Paratkar, G.T.; Jha, S.K.; Puranik, V.D.

    2004-01-01

    Elemental composition of mosses from Mahabaleshwar, a remote hill station near Mumbai was measured. Trace element profiles of two different species of mosses were compared. Chemical analysis for washed and unwashed moss samples was done using Energy Dispersive X-ray Fluorescence Spectrometry (EDXRF) and Instrumental Neutron Activation Analysis (INAA) techniques in an attempt to understand the variation. The comparative concentration of Al, Sr , Zn and Rb in both the mosses reflected the order of abundance of metal in the soil. The enrichment factor of Pb, was found more in Pinnatella alopccuroides than the other one whereas enrichment factor of Cr was more in Pterobryopsis flexiceps compared to Pinnatella alopccuroides. So they can be preferentially used as bioindicators for respective elements. (author)

  10. Distribution of trace elements in land plants and botanical taxonomy with special reference to rare earth elements and actinium

    International Nuclear Information System (INIS)

    Koyama, Mutsuo

    1989-01-01

    Distribution profiles of trace elements in land plants were studied by neutron activation analysis and radioactivity measurements without activation. Number of botanical samples analyzed were more than three thousand in which more than three hundred botanical species were included. New accumulator plants of Co, Cr, Zn, Cd, rare earth elements, Ac, U, etc., were found. Capabilities of accumulating trace elements can be related to the botanical taxonomy. Discussions are given from view points of inorganic chemistry as well as from botanical physiology

  11. Horizontal variation in trace elements and soil characteristics at ...

    African Journals Online (AJOL)

    The aim of this study was to determine the horizontal variation in trace element concentrations and soil indicators in surface soil associated with the geothermal springs at Siloam and Tshipise. Results show that, in general, the trace element concentrations present in the soil decrease with horizontal distance from the ...

  12. Trace Elements Removal from Waster water by Ceratophyllum ...

    African Journals Online (AJOL)

    Trace element contamination in aquatic ecosystems is one of the most important concerning of environmental health. Submerged aquatic plants can be used for the removal of Trace elements. The aim of this study was to investigate how Ceratophyllum demersum could affect on wastewater quality for recycling the ...

  13. Removal of trace element by isolates of Aspergillus brasiliensis ...

    African Journals Online (AJOL)

    Coffee beans processing generates a large volume of wastewater composed of trace elements which can be detrimental to human health. The present study aimed at evaluating the capacity of strains of Aspergillus brasiliensis and Penicillium citrinum in tolerating and removing trace elements namely: Cu, Mn and Zn from ...

  14. Chemical characteristics and trace element concentration of non ...

    African Journals Online (AJOL)

    The present study investigates the details on the aspects of Coal quality such as proximate, ultimate, calorific value and trace element concentration and its impact on human health. Trace elements are present in very low percentage in coal but their concentration increases manifold after coal combustion and utilization.

  15. Relationship between epiphytic lichens, trace elements and gaseous atmospheric pollutants

    NARCIS (Netherlands)

    Dobben, van H.F.; Wamelink, G.W.W.; Braak, ter C.J.F.

    2001-01-01

    A study was conducted to determine the joint effect of gaseous atmospheric pollutants and trace elements on epiphytic lichens. We used our data to test the hypothesis that lichens are generally insensitive to toxic effects of trace elements, and can therefore be used as accumulator organisms to

  16. Biogeochemistry of trace elements and isotopes in the Indian Ocean

    Indian Academy of Sciences (India)

    MassSpec

    2016-07-02

    Jul 2, 2016 ... HNLC (High Nutrient Low Chlorophyll) region in world Ocean. >The low productivity was found to be a result of deficiency of key trace elements, e.g.: Fe. > Trace elements serve as micronutrients and regulates marine ecosystem dynamics and carbon cycle. > They serve as paleo-oceanographic tracers.

  17. Trace Elements in Apple Fruits of Several Regions in the Republic of Macedonia

    International Nuclear Information System (INIS)

    Boev, Blazho; Lepitkova, Sonja; Paneva-Zajkova, Vesna; Georgiev, Lazar

    2006-01-01

    Determination of macro elements and trace elements in apple fruits was carried out by ICP-AES method. Apples were picked up fresh in December 2005. Seven different types of apples from different parts of the country were selected. Apples were sliced into large pieces, dried, and after grinding were dissolved in nitric acid (HNO 3 ) and hydroperoxide (H 2 O 2 ). After digestion, multi-element analysis was carried out. Data obtained were compared to published values for trace elements in apples in other regions of the world. Data obtained indicated that the concentration of trace elements in apples were within the values and data in other regions of the world. (Author)

  18. Beyond the transect: An alternative microchemical imaging method for fine scale analysis of trace elements in fish otoliths during early life

    International Nuclear Information System (INIS)

    McGowan, Nicole; Fowler, Ashley M.; Parkinson, Kerryn; Bishop, David P.; Ganio, Katherine; Doble, Philip A.; Booth, David J.; Hare, Dominic J.

    2014-01-01

    Microchemical analysis of otolith (calcified ‘ear stones’ used for balance and orientation) of fishes is an important tool for studying their environmental history and management. However, the spatial resolution achieved is often too coarse to examine short-term events occurring in early life. Current methods rely on single points or transects across the otolith surface, which may provide a limited view of elemental distributions, a matter that has not previously been investigated. Imaging by laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS) permits microchemical analyses of short-term events in early life with high (< 10 μm) resolution, two-dimensional (2D) visualization of elemental distributions. To demonstrate the potential of this method, we mapped the concentrations of Sr and Ba, two key trace elements, in a small number of juvenile otoliths of neon damselfish (Pomacentrus coelestis) using an 8 μm beam diameter (laser fluence of 13.8 ± 3.5 J cm −2 ). Quantification was performed using the established method by Longerich et al. (1996), which is applied to 2D imaging of a biological matrix here for the first time. Accuracy of > 97% was achieved using a multi-point non matrix-matched calibration of National Institute of Standards and Technology (NIST) 610 and 612 (trace elements in glass) using Longerich's calculation method against the matrix-matched standard FEBS-1 (powdered red snapper [Lutjanus campechanus] otolith). The spatial resolution achieved in the otolith corresponded to a time period of 2 ± 1 days during the larval phase, and 4 ± 1 days during the post-settlement juvenile phase. This method has the potential to improve interpretations of early life-history events at scales corresponding to specific events. While the images showed gradients in Sr and Ba across the larval settlement zone more clearly than single transects, the method proved sample homogeneity throughout the structure; demonstrating that 2D

  19. Beyond the transect: An alternative microchemical imaging method for fine scale analysis of trace elements in fish otoliths during early life

    Energy Technology Data Exchange (ETDEWEB)

    McGowan, Nicole [Elemental Bio-imaging Facility, University of Technology, Sydney, New South Wales (Australia); CCFS ARC Centre of Excellence, Department of Earth and Planetary Sciences, Macquarie University, Sydney (Australia); Fowler, Ashley M.; Parkinson, Kerryn [Fish Ecology Laboratory, School of the Environment, University of Technology, Sydney, New South Wales (Australia); Bishop, David P. [Elemental Bio-imaging Facility, University of Technology, Sydney, New South Wales (Australia); Ganio, Katherine [Florey Department of Neuroscience and Mental Health, University of Melbourne, Victoria (Australia); Doble, Philip A. [Elemental Bio-imaging Facility, University of Technology, Sydney, New South Wales (Australia); Booth, David J. [Fish Ecology Laboratory, School of the Environment, University of Technology, Sydney, New South Wales (Australia); Hare, Dominic J., E-mail: dominic.hare@uts.edu.au [Elemental Bio-imaging Facility, University of Technology, Sydney, New South Wales (Australia); Florey Department of Neuroscience and Mental Health, University of Melbourne, Victoria (Australia)

    2014-10-01

    Microchemical analysis of otolith (calcified ‘ear stones’ used for balance and orientation) of fishes is an important tool for studying their environmental history and management. However, the spatial resolution achieved is often too coarse to examine short-term events occurring in early life. Current methods rely on single points or transects across the otolith surface, which may provide a limited view of elemental distributions, a matter that has not previously been investigated. Imaging by laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS) permits microchemical analyses of short-term events in early life with high (< 10 μm) resolution, two-dimensional (2D) visualization of elemental distributions. To demonstrate the potential of this method, we mapped the concentrations of Sr and Ba, two key trace elements, in a small number of juvenile otoliths of neon damselfish (Pomacentrus coelestis) using an 8 μm beam diameter (laser fluence of 13.8 ± 3.5 J cm{sup −2}). Quantification was performed using the established method by Longerich et al. (1996), which is applied to 2D imaging of a biological matrix here for the first time. Accuracy of > 97% was achieved using a multi-point non matrix-matched calibration of National Institute of Standards and Technology (NIST) 610 and 612 (trace elements in glass) using Longerich's calculation method against the matrix-matched standard FEBS-1 (powdered red snapper [Lutjanus campechanus] otolith). The spatial resolution achieved in the otolith corresponded to a time period of 2 ± 1 days during the larval phase, and 4 ± 1 days during the post-settlement juvenile phase. This method has the potential to improve interpretations of early life-history events at scales corresponding to specific events. While the images showed gradients in Sr and Ba across the larval settlement zone more clearly than single transects, the method proved sample homogeneity throughout the structure; demonstrating that 2D

  20. Determination of essential trace elements in wine by neutron activation analysis; Determinacao de elementos essenciais em vinhos por analise por ativacao com neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Daniele, Anna Paula

    2016-07-01

    Several studies have been carried out for determining essential elements in foodstuffs, including wine, due to its important nutritional role in human body functions. It was shown that daily consumption of wine in moderation contributes significantly to the needs of essential elements in human body such as Ca, Co, Cr, Fe, K, Mg, Mn, Zn, V, among others, and has health benefits in the prevention of numerous diseases and longer life expectancy, related in particular to the intake of antioxidants such as polyphenolic compounds. Trace elements are good indicators of origin of wines and their concentrations can be used as criteria to ensure authenticity, quality and show that the tolerance limits established by law were respected throughout the production process. However, although Brazilian wine industry is among the 15 largest in the world, analytical studies for organic and inorganic compounds of wine content are still small when compared to other major producers. In this sense, this study aimed to evaluate some procedures of wine sample preparation to determine essential elements by Instrumental Neutron Activation Analysis (INAA) and compare the results with those determined by Inductively Coupled Plasma Atomic Emission Spectrometry (ICP OES). Three sample preparation procedures were studied: freeze-drying, evaporation and dry ashing. The parameters studied were precision, accuracy and detection limit. ANOVA and Tukey-Kramer tests were applied to verify the statistical differences between the mean values obtained by the three wine preparation procedures for INAA with those means obtained by ICP OES. It was noticed that about 60% of results obtained by freeze-drying agreed with those obtained by ICP OES. (author)

  1. Impact of trace elements on biocompatibility of titanium scaffolds

    Energy Technology Data Exchange (ETDEWEB)

    Sabetrasekh, R; Tiainen, H; Reseland, J E; Lyngstadaas, S P; Haugen, H J [Department for Biomaterials, Faculty of Dentistry, University of Oslo, PO Box 1109 Blindern, 0317 Oslo (Norway); Will, J [Department of Materials Science and Engineering, Institute of Glass and Ceramics, University of Erlangen-Nuernberg, Henkestr. 91, 91052 Erlangen (Germany); Ellingsen, J E, E-mail: h.j.haugen@odont.uio.n [Faculty of Dentistry, Oral Research Laboratory, University of Oslo, PO Box 1109 Blindern, 0317 Oslo (Norway)

    2010-02-15

    A titanium oxide scaffold has recently been reported with high compressive strength (>2 MPa) which may allow its use in bone. However, would it be possible to enhance the scaffolds' performance by selecting a titanium oxide raw material without elemental contamination? Elements in implant surfaces have been reported to provoke implant failure. Thus, this study aims to compare different commercial titanium dioxide powders in order to choose the appropriate powder for scaffold making. The x-ray photoelectron spectroscopy (XPS) analysis identified the trace elements, mainly Al, Si, C, Ca and P. Cellular response was measured by cytotoxic effect, cell growth and cytokine secretion from murine preosteoblasts (MC3T3-E1) in vitro. The XPS data showed that traces of carbon-based molecules, silicon, nitrogen and aluminium in the powder were greatly reduced after cleaning in 1 M NaOH. As a result, reduction in cytotoxicity and inflammatory response was observed. Carbon contamination seemed to have a minor effect on the cellular response. Strong correlations were found between Al and Si contamination levels and the inflammatory response and cytotoxic effect. Thus, it is suggested that the concentration of these elements should be reduced in order to enhance the scaffolds' biocompatibility.

  2. Studies of trace element determinations in nails by neutron activation analysis method; Estudo de elementos traco em unhas pelo metodo de analise por ativacao com neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Aguiar, Amilton Reinaldo; Saiki, Mitiko [Instituto de Pesquisas Energeticas e Nucleares (IPEN), Sao Paulo, SP (Brazil)

    1996-07-01

    The purpose of this work was to develop the neutron activation analysis for trace element determinations in nails in order to apply this method to the study of the cystic fibrosis disease. It was verified that the elements Al, As, Br, Ca, Cd, Cl, Co, Cr, Cu, Fe, K, Mg, Mn, Na, Se and Zn can be determined by using short and long irradiations with thermal neutron flux from 10{sup 11} to 10{sup 13} n.cm{sup -2}.{sup -1} at the IEA-R1 nuclear research reactor. The washing solutions of triton-X100, NH{sub 4} OH and acetone were tested in order to eliminate external contaminants from the nail samples. The nail analyses of the individual fingers from both of hands showed that the samples must be collected from all the fingers from both of hands to have a representative sample. The precision and the accuracy of the results were also examined by analyzing NIES 10C Rice Flour, IUPAC Bowen's Kale and NIST 1572 Citrus Leaves reference materials. (author)

  3. Evaluation of dietary status with respect to trace element intake from dry fruits consumed in Pakistan: a study using instrumental neutron activation analysis.

    Science.gov (United States)

    Waheed, Shahida; Siddique, Naila

    2009-06-01

    Instrumental neutron activation analysis has been utilized for the quantification of 24 major, minor and trace elements in dried apricots (Prunus armeniaca), dates (Phoenix dectylifera), figs (Ficus carica) and raisins (Vitis vinifera) using a low-power reactor as the neutron source. The weekly intakes of aluminium, arsenic, boron, calcium, chlorine, cobalt, chromium, iron, mercury, potassium, sodium, magnesium, manganese, molybdenum, antimony, selenium and zinc have been calculated and compared with the Recommended Dietary Allowance/Estimated Safe and Adequate Dietary Intake values through consumption of 100 g dried fruit. Fairly adequate levels of calcium, cobalt, iron, potassium and magnesium were determined in these dried fruits while the contribution of chlorine, chromium, molybdenum and sodium to the Recommended Dietary Allowance was found to be insignificant. Apricot is a nutritionally rich source of potassium, magnesium and cobalt, while chlorine and manganese contents were found to be highest in dates. Figs are an ample source of calcium, iron, magnesium and manganese, whereas raisins provide the highest intake of chromium, molybdenum and sodium. The toxic element contents of these dry fruits are considerably below the tolerance limits.

  4. Trace elements in sickle cell disease

    International Nuclear Information System (INIS)

    Durosinmi, M.A.; Ojo, J.O.; Oluwole, A.F.; Akanle, O.A.; Arshed, W.; Spyrou, N.M.

    1993-01-01

    Instrumental Neutron Activation Analysis (INAA) and Proton-Induced X-ray Emission (PIXE) analysis (employed as a complementary technique) have been used to determine the concentration of 11 elements in blood samples and its components erythrocytes and plasma obtained from three groups of subjects in Nigeria viz: sickle cell anaemia (SCA) subjects, subjects with sickle cell trait and normal control subjects. The results suggest that SCA subjects have significantly higher concentrations of Na, Cl, Ca and Cu in their whole blood and erythrocytes and a higher concentration of Cl and Cu in their plasma relative to control subjects. Furthermore, a significantly lower concentration of K, Fe, Zn, Se, Br and Rb were found in the whole blood and erythrocytes of the SCA subjects as compared to the controls while the concentration of K and Fe in the plasma of the SCA subjects were however, found to be significantly higher than that of the control group. The study also shows that there were no significant differences between the concentration of these 11 elements in the group with sickle cell trait and the normal control group. (author) 20 refs.; 4 tabs

  5. Trace elements in a dated ice core from Antarctica

    International Nuclear Information System (INIS)

    Keshin, S.S.; Xudong Huang; Olmez, I.; Langway, C.C. Jr.

    1992-01-01

    Aerosol particles from both natural and anthropogenic sources are emitted into the atmosphere and transported by wind systems by various mechanisms. Once airborne, the particles, which contain various trace elements, accumulate on the earth's surface as either condensation nuclei or by dry fallout processes. In the polar regions, these particles are incorporated and deposited in snow layers in sequential time-unit increments. The trace analysis of elements contained in dated annual snow layers provides a measure of the elemental chemistry content of the atmosphere for the same time interval. A 164-m-deep, 10-cm-diam ice core was obtained at Byrd Station, Antarctica, in November 1989. Other physical and chemistry studies on this ice core have identified its detailed chronology in annual increments for the past 1360 yr. This study presents the results of the instrumental neutron activation analysis (INAA) measurements made on 26 individually dated samples of this core, selected between the 6.43- and 118.15-m depths

  6. Mercury, trace elements and organic constituents in atmospheric fine particulate matter, Shenandoah National Park, Virginia, USA: A combined approach to sampling and analysis

    Science.gov (United States)

    Kolker, A.; Engle, M.A.; Orem, W.H.; Bunnell, J.E.; Lerch, H.E.; Krabbenhoft, D.P.; Olson, M.L.; McCord, J.D.

    2008-01-01

    Compliance with U.S. air quality regulatory standards for atmospheric fine particulate matter (PM2.5) is based on meeting average 24 hour (35 ?? m-3) and yearly (15 ??g m-3) mass-per-unit-volume limits, regardless of PM2.5 composition. Whereas this presents a workable regulatory framework, information on particle composition is needed to assess the fate and transport of PM2.5 and determine potential environmental/human health impacts. To address these important non-regulatory issues an integrated approach is generally used that includes (1) field sampling of atmospheric particulate matter on filter media, using a size-limiting cyclone, or with no particle-size limitation; and (2) chemical extraction of exposed filters and analysis of separate particulate-bound fractions for total mercury, trace elements and organic constituents, utilising different USGS laboratories optimised for quantitative analysis of these substances. This combination of sampling and analysis allowed for a more detailed interpretation of PM2.5 sources and potential effects, compared to measurements of PM2.5 abundance alone. Results obtained using this combined approach are presented for a 2006 air sampling campaign in Shenandoah National Park (Virginia, USA) to assess sources of atmospheric contaminants and their potential impact on air quality in the Park. PM2.5 was collected at two sampling sites (Big Meadows and Pinnacles) separated by 13.6 km. At both sites, element concentrations in PM2.5 were low, consistent with remote or rural locations. However, element/Zr crustal abundance enrichment factors greater than 10, indicating anthropogenic input, were found for Hg, Se, S, Sb, Cd, Pb, Mo, Zn and Cu, listed in decreasing order of enrichment. Principal component analysis showed that four element associations accounted for 84% of the PM 2.5 trace element variation; these associations are interpreted to represent: (1) crustal sources (Al, REE); (2) coal combustion (Se, Sb), (3) metal production

  7. Bioaccessibility of 12 trace elements in marine molluscs.

    Science.gov (United States)

    He, Mei; Wang, Wen-Xiong

    2013-05-01

    We conducted a large scale investigation of the bioaccessibility of 12 trace elements from 11 marine mollusc species (scallop, oyster, clam, abalone, snail, and mussel) collected from five locations in Chinese coastal waters. The bioaccessibility of all the 12 trace elements was generally high, with the average values ranging from 42.5% to 90.7%. The highest bioaccessibility was observed for As, Cu, Ni and Se, and the lowest for Fe, Co and Pb. Steaming decreased the bioaccessibility of all 12 trace elements and thus diminished their risks. No correlation was observed between the bioaccessibility and the total concentration of the 12 elements. However, there was a significant correlation between the bioaccessibility of the 12 elements and their subcellular distribution. For most trace elements, a significantly negative relationship was demonstrated between the bioaccessibility and the elemental partitioning in the metal-rich granule fraction or in the cellular debris fraction, and a significantly positive correlation was observed between the bioaccessibility and the elemental partitioning in the heat-stable protein fraction and in the trophically available fraction. Hence, the elemental subcellular distribution, especially the elemental partitioning in the trophically available fraction, might be a good predictor of the bioaccessibility and risks of trace elements in molluscs. Copyright © 2013 Elsevier Ltd. All rights reserved.

  8. Development of an approach for qualitative and quantitative analysis of trace elements present in canine breast tumors by energy dispersive X-ray fluorescence

    Energy Technology Data Exchange (ETDEWEB)

    Cozer, Thamara C.; Conceicao, Andre L.C.; Paschuk, Sergei A.; Rocha, Anna S.S. da; Fagundes, Alana C.F.; Maciel, Karla F.R.; Pimentel, Gustavo R.O.; Badelli, Juliana C., E-mail: thamara.cozer@gmail.com, E-mail: alconceicao@utfpr.edu.br, E-mail: sergei@utfpr.edu.br, E-mail: anna@utfpr.edu.br, E-mail: alanacarolinef@gmail.com, E-mail: karla_rimanski@hotmail.com, E-mail: g_rop@hotmail.com, E-mail: jubadellin@gmail.com [Universidade Tecnologica Federal do Parana (UTFPR), Curitiba, PR (Brazil). Lab. de Espectroscopia de Raio-X

    2015-07-01

    Studies performed with canines indicate that one of the main neoplasia which affect these animals are the breast tumors, representing from 25% to 50% of all kinds of tumors. Moreover, half of them are classified as malignant. In this sense, recent researches on humans have been associated the presence of certain trace elements with the development of breast neoplasia in those individuals. Then, as the breast tissue composition in canines is very similar to the humans, it is expected the same behavior. In this direction, a very effective technique to identify and to determinate trace elements concentration is the EDXRF. However, studies on this area are scarce in the literature. Therefore, in this work it was developed an approach to quantify the main trace elements present into these tumors with high sensitivity. For this purpose, it was determined calibration curves of standards samples diluted in water, with concentrations of Ca, Fe, Cu and Zn, ranging from 400mg/kg to 35mg/kg, from 20mg/kg to 2mg/kg, from 10mg/kg to 1mg/kg and from 100mg/kg to 10mg/kg, respectively. All calibration curves were linearly fitted and on basis in this behavior it was determined the sensitivity of our approach to quantify the concentration of the trace elements mentioned above. In addition, it is important to mention that studies in this area are of great potential, because EDXRF represents a quickly practical and non-destructive alternative to quantify trace elements. (author)

  9. Development of an approach for qualitative and quantitative analysis of trace elements present in canine breast tumors by energy dispersive X-ray fluorescence

    International Nuclear Information System (INIS)

    Cozer, Thamara C.; Conceicao, Andre L.C.; Paschuk, Sergei A.; Rocha, Anna S.S. da; Fagundes, Alana C.F.; Maciel, Karla F.R.; Pimentel, Gustavo R.O.; Badelli, Juliana C.

    2015-01-01

    Studies performed with canines indicate that one of the main neoplasia which affect these animals are the breast tumors, representing from 25% to 50% of all kinds of tumors. Moreover, half of them are classified as malignant. In this sense, recent researches on humans have been associated the presence of certain trace elements with the development of breast neoplasia in those individuals. Then, as the breast tissue composition in canines is very similar to the humans, it is expected the same behavior. In this direction, a very effective technique to identify and to determinate trace elements concentration is the EDXRF. However, studies on this area are scarce in the literature. Therefore, in this work it was developed an approach to quantify the main trace elements present into these tumors with high sensitivity. For this purpose, it was determined calibration curves of standards samples diluted in water, with concentrations of Ca, Fe, Cu and Zn, ranging from 400mg/kg to 35mg/kg, from 20mg/kg to 2mg/kg, from 10mg/kg to 1mg/kg and from 100mg/kg to 10mg/kg, respectively. All calibration curves were linearly fitted and on basis in this behavior it was determined the sensitivity of our approach to quantify the concentration of the trace elements mentioned above. In addition, it is important to mention that studies in this area are of great potential, because EDXRF represents a quickly practical and non-destructive alternative to quantify trace elements. (author)

  10. Trace element fingerprinting of jewellery rubies by external beam PIXE

    Energy Technology Data Exchange (ETDEWEB)

    Calligaro, T. E-mail: calli@culture.nl; Poirot, J.-P.; Querre, G

    1999-04-02

    External beam PIXE analysis allows the non-destructive in situ characterisation of gemstones mounted on jewellery pieces. This technique was used for the determination of the geographical origin of 64 rubies set on a high-valued necklace. The trace element content of these gemstones was measured and compared to that of a set of rubies of known sources. Multivariate statistical processing of the results allowed us to infer the provenance of rubies: one comes from Thailand/Cambodia deposit while the remaining are attributed to Burma. This highlights the complementary capabilities of PIXE and conventional geological observations.

  11. Trace element fingerprinting of jewellery rubies by external beam PIXE

    International Nuclear Information System (INIS)

    Calligaro, T.; Poirot, J.-P.; Querre, G.

    1999-01-01

    External beam PIXE analysis allows the non-destructive in situ characterisation of gemstones mounted on jewellery pieces. This technique was used for the determination of the geographical origin of 64 rubies set on a high-valued necklace. The trace element content of these gemstones was measured and compared to that of a set of rubies of known sources. Multivariate statistical processing of the results allowed us to infer the provenance of rubies: one comes from Thailand/Cambodia deposit while the remaining are attributed to Burma. This highlights the complementary capabilities of PIXE and conventional geological observations

  12. Trace element fingerprinting of jewellery rubies by external beam PIXE

    Science.gov (United States)

    Calligaro, T.; Poirot, J.-P.; Querré, G.

    1999-04-01

    External beam PIXE analysis allows the non-destructive in situ characterisation of gemstones mounted on jewellery pieces. This technique was used for the determination of the geographical origin of 64 rubies set on a high-valued necklace. The trace element content of these gemstones was measured and compared to that of a set of rubies of known sources. Multivariate statistical processing of the results allowed us to infer the provenance of rubies : one comes from Thailand/Cambodia deposit while the remaining are attributed to Burma. This highlights the complementary capabilities of PIXE and conventional gemological observations.

  13. Trace and major element compositions of Black Sea aerosol

    International Nuclear Information System (INIS)

    Karakas, D.; Oelmez, I.; Tosun, S.; Tuncel, G.

    2004-01-01

    Instrumental neutron activation analysis (INAA), flame atomic absorption spectrometry (FAAS), flame atomic emission spectrometry (FAES), graphite furnace atomic absorption spectrometry (GF-AAS), ion chromatography (IC) and visible spectrometry (VIS) were used to determine the composition of atmospheric aerosols, collected at a rural site in the Western Black Sea Coast of Turkey. A total of 354 daily aerosol samples were analyzed for 46 trace and major elements and ions. Sample preparation, quality control procedures, instrumental operating conditions for INAA and source apportionment work is presented. (author)

  14. Gene expression analysis of 4 biomarker candidates in Eisenia fetida exposed to an environmental metallic trace elements gradient: A microcosm study

    Energy Technology Data Exchange (ETDEWEB)

    Brulle, Franck; Lemiere, Sebastien [Univ Lille Nord de France, F-59000 Lille (France); LGCgE, Equipe Ecologie Numerique et Ecotoxicologie, Lille 1, F-59650 Villeneuve d' Ascq (France); Waterlot, Christophe; Douay, Francis [Univ Lille Nord de France, F-59000 Lille (France); LGCgE, Equipe Sols et Environnement, Groupe ISA, 48 boulevard Vauban, F-59046 Lille Cedex (France); Vandenbulcke, Franck, E-mail: franck.vandenbulcke@univ-lille1.fr [Univ Lille Nord de France, F-59000 Lille (France); LGCgE, Equipe Ecologie Numerique et Ecotoxicologie, Lille 1, F-59650 Villeneuve d' Ascq (France)

    2011-11-15

    Past activities of 2 smelters (Metaleurop Nord and Nyrstar) led to the accumulation of high amounts of Metal Trace Elements (TEs) in top soils of the Noyelles-Godault/Auby area, Northern France. Earthworms were exposed to polluted soils collected in this area to study and better understand the physiological changes, the mechanisms of acclimation, and detoxification resulting from TE exposure. Previously we have cloned and transcriptionally characterized potential biomarkers from immune cells of the ecotoxicologically important earthworm species Eisenia fetida exposed in vivo to TE-spiked standard soils. In the present study, analysis of expression kinetics of four candidate indicator genes (Cadmium-metallothionein, coactosin like protein, phytochelatin synthase and lysenin) was performed in E. fetida after microcosm exposures to natural soils exhibiting an environmental cadmium (Cd) gradient in a kinetic manner. TE body burdens were also measured. This microcosm study provided insights into: (1) the ability of the 4 tested genes to serve as expression biomarkers, (2) detoxification processes through the expression analysis of selected genes, and (3) influence of land uses on the response of potential biomarkers (gene expression or TE uptake). - Highlights: {yields} Expression biomarkers in animals exposed to Cadmium-contaminated field soils. {yields} Expression kinetics to test the ability of genes to serve as expression biomarkers. {yields} Study of detoxification processes through the expression analysis of selected genes.

  15. Trace element accumulation in lotic dragonfly nymphs: Genus matters.

    Science.gov (United States)

    Fletcher, Dean E; Lindell, Angela H; Stillings, Garrett K; Blas, Susan A; McArthur, J Vaun

    2017-01-01

    Constituents of coal combustion waste (CCW) expose aquatic organisms to complex mixtures of potentially toxic metals and metalloids. Multi-element trace element analyses were used to distinguish patterns of accumulation among 8 genera of dragonfly nymphs collected from two sites on a CCW contaminated coastal plain stream. Dragonfly nymphs are exceptional for comparing trace element accumulation in syntopic macroinvertebrates that are all predators within the same order (Odonata) and suborder (Anisoptera), but differ vastly in habitat use and body form. Sixteen trace element (Be, V, Cr, Ni, Cu, Zn, As, Se, Sr, Cd, Sb, Cs, Ba, Hg, Tl, and Pb) were analyzed and trophic position and basal carbon sources assessed with stable isotope analyses (C and N). Trophic positions varied within relatively narrow ranges. Size did not appear to influence trophic position. Trophic position rarely influenced trace element accumulation within genera and did not consistently correlate with accumulation among genera. Patterns between δ13C and trace element accumulation were generally driven by differences between sites. An increase in trace element accumulation was associated with a divergence of carbon sources between sites in two genera. Higher trace element concentrations tended to accumulate in nymphs from the upstream site, closer to contaminant sources. Influences of factors such as body form and habitat use appeared more influential on trace element accumulation than phylogeny for several elements (Ni, Ba, Sr, V, Be, Cd, and Cr) as higher concentrations accumulated in sprawler and the climber-sprawler genera, irrespective of family. In contrast, As and Se accumulated variably higher in burrowers, but accumulation in sprawlers differed between sites. Greater variation between genera than within genera suggests genus as an acceptable unit of comparison in dragonfly nymphs. Overall, taxonomic differences in trace element accumulation can be substantial, often exceeding variation

  16. The EU network on trace element speciation in full swing

    DEFF Research Database (Denmark)

    Cornelis, R.; Camara, C.; Ebdon, L.

    2000-01-01

    The EC-funded thematic network 'Speciation 21' links scientists in analytical chemistry working in method development for the chemical speciation of trace elements, and potential users from industry and representatives of legislative agencies, in the field of environment, food and occupational...... as the influence of packing materials. Once the analytical methodology for the measurement of the trace element species has been optimised, the importance of trace element speciation will grow enormously. Food sciences, material sciences, medicine and occupational health, environmental sciences and related fields...

  17. Progress of pharmacogenomic research related to minerals and trace elements.

    Science.gov (United States)

    Zeng, Mei-Zi; Tang, Jie; Liu, Zhao-Qian; Zhou, Hong-Hao; Zhang, Wei

    2015-10-01

    Pharmacogenomics explores the variations in both the benefits and the adverse effects of a drug among patients in a target population by analyzing genomic profiles of individual patients. Minerals and trace elements, which can be found in human tissues and maintain normal physiological functions, are also in the focus of pharmacogenomic research. Single-nucleotide polymorphisms (SNPs) affect the metabolism, disposition and efficacy of minerals and trace elements in humans, resulting in changes of body function. This review describes some of the recent progress in pharmacogenomic research related to minerals and trace elements.

  18. A new AMS with RFQ LINAC for trace elements

    International Nuclear Information System (INIS)

    Ueda, Shintaro; Hattori, Toshiyuki; Hayashizaki, Noriyosu; Hata, Toshiki; Kawasaki, Katunori

    2004-01-01

    Accelerator Mass Spectrometry (AMS) is able to measure abundance ratio of the radioisotope, and measurable limit is about 1 x 10 -15 (ppq). Measurable limit is very excellent comparison with other analyzers for trace element. Therefore we have studied a new AMS for trace element. Our system is combined LINAC with a multivalent ion source. The features of new system are following: trace elemental analyses by detect energy of particles, and miniaturization of the system. We are going to report a condition of study. (author)

  19. Trace elements induce predominance among methanogenic activity in anaerobic digestion

    Directory of Open Access Journals (Sweden)

    Babett Wintsche

    2016-12-01

    Full Text Available Trace elements play an essential role in all organisms due to their functions in enzyme complexes. In anaerobic digesters, control and supplementation of trace elements lead to stable and more efficient methane production processes while trace element deficits cause process imbalances. However, the underlying metabolic mechanisms and the adaptation of the affected microbial communities to such deficits are not yet fully understood. Here, we investigated the microbial community dynamics and resulting process changes induced by trace element deprivation. Two identical lab-scale continuous stirred tank reactors fed with distiller’s grains and supplemented with trace elements (cobalt, molybdenum, nickel, tungsten and a commercial iron additive were operated in parallel. After 72 weeks of identical operation, the feeding regime of one reactor was changed by omitting trace element supplements and reducing the amount of iron additive. Both reactors were operated for further 21 weeks. Various process parameters (biogas production and composition, total solids and volatile solids, trace element concentration, volatile fatty acids, total ammonium nitrogen, total organic acids/alkalinity ratio, and pH and the composition and activity of the microbial communities were monitored over the total experimental time. While the methane yield remained stable, the concentrations of hydrogen sulfide, total ammonia nitrogen, and acetate increased in the trace element-depleted reactor compared to the well-supplied control reactor. Methanosarcina and Methanoculleus dominated the methanogenic communities in both reactors. However, the activity ratio of these two genera was shown to depend on trace element supplementation explainable by different trace element requirements of their energy conservation systems. Methanosarcina dominated the well-supplied anaerobic digester, pointing to acetoclastic methanogenesis as the dominant methanogenic pathway. Under trace element

  20. Trace elements in Mediterranean seagrasses and macroalgae. A review.

    Science.gov (United States)

    Bonanno, Giuseppe; Orlando-Bonaca, Martina

    2018-03-15

    This review investigates the current state of knowledge on the levels of the main essential and non-essential trace elements in Mediterranean vascular plants and macroalgae. The research focuses also on the so far known effects of high element concentrations on these marine organisms. The possible use of plants and algae as bioindicators of marine pollution is discussed as well. The presence of trace elements is overall well known in all five Mediterranean vascular plants, whereas current studies investigated element concentrations in only c. 5.0% of all native Mediterranean macroalgae. Although seagrasses and macroalgae can generally accumulate and tolerate high concentrations of trace elements, phytotoxic levels are still not clearly identified for both groups of organisms. Moreover, although the high accumulation of trace elements in seagrasses and macroalgae is considered as a significant risk for the associated food webs, the real magnitude of this risk has not been adequately investigated yet. The current research provides enough scientific evidence that seagrasses and macroalgae may act as effective bioindicators, especially the former for trace elements in sediments, and the latter in seawater. The combined use of seagrasses and macroalgae as bioindicators still lacks validated protocols, whose application should be strongly encouraged to biomonitor exhaustively the presence of trace elements in the abiotic and biotic components of coastal ecosystems. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Developed determination method of ultra trace elements and ultra trace element levels in plasma of rat fed low magnesium diet.

    Science.gov (United States)

    Kimura, Mieko; Honda, Kazuto; Takeda, Atsuko; Imanishi, Masayo; Takeda, Takahisa

    2004-12-01

    Homeostatic mechanisms keep plasma mineral concentrations largely unchangeable, and are not always reflective of the nutritional status. For that reason, nutritional assessment is difficult and another biological index may be of value. Recently, improvement of measuring instruments has permitted more accurate measurement of trace and ultra trace elements. A new determination method for trace and ultra trace elements in rat plasma, that uses an inductively coupled plasma mass spectrometry (ICP-MS Elan-6000, Perkin Elmer, Co., USA) without pre-treatment has enabled study of basic data of ultra trace element concentrations for the first time. The effect of low magnesium (Mg) intake, as compared with the effect of a normal diet, status of 10 trace and ultra trace element status was studied in 12 young male Wistar rats (3-weeks-old), divided into two groups and fed a normal diet or low Mg diet for 4 weeks. The plasma was diluted with ultra pure water (TAMAPURE-AA: Tama Chemical Co., Japan). Ten trace and ultra trace element (As: 75, Se: 82, Rb: 85, Sr: 87, Mo: 95, Ba: 137, Ta: 181, Ir: 193, Au: 197, Pb: 208) concentrations in the plasma were measured with ICP-MS Elan 6000. As, Rb, Sr, Ta, Ir and Au concentrations were significantly high in the plasma of low Mg rats, compared to levels in rats fed normal diets. Essentiality for mammals has been certified for Se, Rb, Mo, As and Pb, but not yet for Sr, Ba, Au, Ir and Ta. These results prove that trace and ultra trace element concentrations in plasma are changeable by nutritional conditions, and suggest that new physiological functions may be found for these elements, and that they may be proved to be essential for mammals.

  2. Trace elements in oil shale. Progress report, 1979-1980

    Energy Technology Data Exchange (ETDEWEB)

    Chappell, W R

    1980-01-01

    The purpose of this research program is to understand the potential impact of an oil shale industry on environmental levels of trace contaminants in the region. The program involves a comprehensive study of the sources, release mechanisms, transport, fate, and effects of toxic trace chemicals, principally the trace elements, in an oil shale industry. The overall objective of the program is to evaluate the environmental and health consequences of the release of toxic trace elements by shale and oil production and use. The baseline geochemical survey shows that stable trace elements maps can be constructed for numerous elements and that the trends observed are related to geologic and climatic factors. Shale retorted by above-ground processes tends to be very homogeneous (both in space and in time) in trace element content. Leachate studies show that significant amounts of B, F, and Mo are released from retorted shales and while B and Mo are rapidly flushed out, F is not. On the other hand, As, Se, and most other trace elements are not present in significant quantities. Significant amounts of F and B are also found in leachates of raw shales. Very large concentrations of reduced sulfur species are found in leachates of processed shale. Very high levels of B and Mo are taken up in some plants growing on processed shale with and without soil cover. There is a tendency for some trace elements to associate with specific organic fractions, indicating that organic chelation or complexation may play an important role. Many of the so-called standard methods for analyzing trace elements in oil shale-related materials are inadequate. A sampling manual is being written for the environmental scientist and practicing engineer. A new combination of methods is developed for separating the minerals in oil shale into different density fractions. Microbial investigations have tentatively identified the existence of thiobacilli in oil shale materials such as leachates. (DC)

  3. Development and characterization of a portable total reflection X-ray fluorescence system using a waveguide for trace elements analysis.

    Science.gov (United States)

    da Costa, Ana Cristina M; de Araújo, Ubiratan B; de Jesus, Edgar F O; Anjos, Marcelino J; Lopes, Ricardo T

    2014-01-01

    This paper presents a portable total reflection X-ray fluorescence system composed of a 15 W X-ray tube, with a gold anode, a waveguide constituted by two Perspex(®) parallel plates, a Si PIN detector and a quartz optical flat. The critical angle of the total reflection system was experimentally determined by measuring a zinc solution (100 mg/L). The accuracy of the system was checked using SRM 1577b Bovine Liver by NIST as standard reference material. We obtained the absolute detection limits of the following elements: P (450 ± 40 ng), S (200 ± 31 ng), K (30 ± 2.5 ng), Ca (19 ± 3.5 ng), Mn (4.1 ± 0.5 ng), Fe (3.6 ± 0.9 ng), Cu (3.3 ± 0.4 ng) and Zn (3.5 ± 0.3 ng). This paper shows that it is possible to produce total reflection X-ray fluorescence with very compact, efficient, low-cost and easy-to-handle instrumentation using a low-power X-ray tube and a Si PIN compact detector.

  4. Trace elemental analysis of glass and paint samples of forensic interest by ICP-MS using laser ablation solid sample introduction

    Science.gov (United States)

    Almirall, Jose R.; Trejos, Tatiana; Hobbs, Andria; Furton, Kenneth G.

    2003-09-01

    -six automotive glasses (side windows and windshields) representing casework glass from different vehicle manufacturers over several years was also characterized by RI and elemental composition analysis. The solution sample introduction techniques (external calibration and isotope dilution) provide for excellent sensitivity and precision but have the disadvantages of destroying the sample and also involve complex sample preparation. The laser ablation method was simpler, faster and produced comparable discrimination to the EC-ICP-MS and ID-ICP-MS. LA-ICP-MS can provide for an excellent alternative to solution analysis of glass in forensic casework samples. Paints and coatings are frequently encountered as trace evidence samples submitted to forensic science laboratories. A LA-ICP-MS method has been developed to complement the commonly used techniques in forensic laboratories in order to better characterize these samples for forensic purposes. Time-resolved plots of each sample can be compared to associate samples to each other or to discriminate between samples. Additionally, the concentration of lead and the ratios of other elements have been determined in various automotive paints by the reported method. A sample set of eighteen (18) survey automotive paint samples have been analyzed with the developed method in order to determine the utility of LA-ICP-MS and to compare the method to the more commonly used scanning electron microscopy (SEM) method for elemental characterization of paint layers in forensic casework.

  5. Spatial and temporal characterization of trace elements and nutrients in the Rawal Lake Reservoir, Pakistan using multivariate analysis techniques.

    Science.gov (United States)

    Malik, Riffat Naseem; Nadeem, Muhammad

    2011-12-01

    Rawal Lake Reservoir is renowned for its ecological significance and is the sole source of drinking water of the third largest city of Pakistan. However, fish kill in recent years and anthropogenic impacts from human-related activities in its catchment area have resulted in deterioration of its surface water quality. This study aims to characterize spatial and temporal variations in surface water quality, identify contaminant sources, and compare their levels with quality guidelines. Surface water samples were collected from 10 sites and analyzed for 27 physicochemical parameters for a period of 2 years on a seasonal basis. Concentration of metals in surface water in pre-monsoon were in the order: Fe > Mg > Ca > Mn > Zn > Ni > Cr > Cu > Co > Pb, whereas in post-monsoon, the order of elemental concentrations was: Ca > Mg > Na > Fe > K > Zn > Cr > Li > Pb > Co > Ni > Cu > Mn > Cd. Metals (Ni, Fe, Zn, and Ca), pH, electrical conductivity (EC), dissolved oxygen (DO), chemical oxygen demand (COD), and nutrients (PO (4) (3-) , NO(3)-N, and SO (4) (2-) ) were measured higher in pre-monsoon, whereas concentration of Cu, Mn, Cr, Co, Pb, Cd, K, Na, Mg, Li, Cl(-), and NH(4)-N were recorded higher in post-monsoon. Results highlighted serious metal pollution of surface water. Mean concentration of Zn, Cd, Ni, Cu, Fe, Cr, and Pb in both seasons and Mn in post-monsoon were well above the permissible level of surface water quality criteria. Results stress the dire need to reduce heavy-metal input into the lake basin and suggest that heavy-metal contamination should be considered as an integral part of future planning and management strategies for restoration of water quality of the lake reservoir.

  6. Trace elements in quartz from Li-enriched pegmatite

    Czech Academy of Sciences Publication Activity Database

    Breiter, Karel; Svojtka, Martin; Ďurišová, Jana; Ackerman, Lukáš; Novák, M.

    2014-01-01

    Roč. 160, č. 1 (2014), s. 31-36 ISSN 1609-0144. [Pegmatite : Österreichische Arbeitstagung /1./. Leoben, 11.04.2014] Institutional support: RVO:67985831 Keywords : trace elements * pegmatite Subject RIV: DB - Geology ; Mineralogy

  7. Trace element analysis in geochemistry using a nuclear microprobe. Ionoluminescence and particle induced X-ray emission

    International Nuclear Information System (INIS)

    Homman, P.

    1994-01-01

    In PIXE analysis of geological specimens based on X-ray detection with Si(Li) detectors, effects of detector tailing, pulse pileup, and gamma-ray production are pronounced. In this work the tailing effect has been addressed through characterization of the response function of a Si(Li) detector using an absorber technique. The pileup interval, in the pulse forming electronics of a PIXE detection system, has been improved to 100 ns X-ray energies above 8 keV by means of pulse shape analysis. Pulses due to tailing effects were also isolated but no major improvement was obtained. A means of reducing the increased background in the PIXE spectrum due to Compton scattering of high energetic gamma-rays in the Si(Li) crystal has been investigated by installation of an anti-Compton shield consisting of an organic scintillator mounted inside the detector cryostat and read out by a photomultiplier. Ionoluminescence, a new analytical technique for the nuclear microprobe, has shown to be a technique that can be employed as a fast diagnostic tool in imaging applications. The technique is based on analysis of the light that often can be observed when an ion beam impinges on a geological specimen. This light, luminescence, can often be associated with impurities in the crystal lattice or other structural defects. It can therefore be employed for revealing some chemical information about the specimens in contradiction to PIXE which is rather insensitive to chemical variations. The potential of the method is demonstrated and discussed both as an imaging tool and for spectroscopic studies. 19 refs, 10 figs

  8. Trace elements in airborne particulates in South Africa

    International Nuclear Information System (INIS)

    Vleggaar, C.M.; Van As, D.; Watkins, J.L.; Mingay, D.W.; Wells, R.B.; Briggs, A.B.; Louw, C.W.

    1980-10-01

    Airborne particulate materials were monitored continously with calendar month sampling periods at 5 rural/background, 4 rural/developing/peri-urban, 6 urban and 7 industrial sites in South Africa. Concentrations of Al, Br, Ca, Cs, Cd, Cl, Co, Cr, Cu, Eu, Fe, K, Mg, Mn, Na, Ni, Pb, Rb, S, Sb, Sc, Se, Ti, V and Zn were determined with neutron activation analysis (NAA), atomic absorption spectroscopy (AAS) and particle-induced X-ray emission spectroscopy (PIXE) employed on a complementary basis. A review of sources of airborne trace elements is given. The monitoring program, sampling, sample-handling procedures, as well as the analytical methods used, are discussed in detail. The results of related studies, i.e. effects of filter materials; sampling rates and geometry; determinations of collection efficiencies; particle size ranges; effects of internal flux monitors on the precision and accuracy of NAA; trace impurities in blank materials; quality control by routine analysis of reference materials; comparison of results obtained by NAA, AAS, and PIXE analysis; are given, as is a review of air-pollution control and research policy in South Africa and of ambient air quality standards. Results are discussed in terms of general patterns in trace-element concentrations and enrichments, the general pattern in population centres, the variability of monthly concentrations, and in terms of long-term trends at background, rural, developing, peri-urban, urban and industrial sites. Cases of concern in respect of increasing concentrations are pointed out, as are the constantly high Pb levels at urban sites [af

  9. Environmental lichenology: Biomonitoring trace-element air pollution

    Energy Technology Data Exchange (ETDEWEB)

    Sloof, J.E.

    1993-09-27

    Chapter 1 describes the possibilities to study trace-element air pollution in order to get insight in the character and element levels of such pollution. Chapter 2 describes two monitoring surveys using Parmelia sulcata Taylor on a national scale, in which spatial and temporal patterns of heavy metals were investigated. The surveys were carried out in 1982-1983 at 110 sampling sites and in 1986-1987 at 210 sampling sites. From these studies it was concluded that lichens are at least good qualitative biomonitors for atmospheric trace-element levels. Chapter 3 describes the response of lichens to the cesium-137 activity as a result of the Chernobyl accident, deposited by rainfall in the Netherlands. From this study it was concluded that lichens are good biomonitors for atmospheric cesium-137 activity too. Chapter 4 describes the application of factor analysis to a lichen data set from a monitoring survey on a national scale (1986-1987), for source apportionment. In Chapter 5 a field study is described on the contribution of a possible influence from the soil to element concentrations in Parmelia sulcata Taylor growing on trees in a an area with polluted soil. Chapter 6 describes a field study on the interchangeability of two tolerant lichen species (Parmelia sulcata Taylor and Lecanora conizaeoides Nyl.) in a polluted area. In Chapter 7 a field study is described in which the quantitative relationships between concentrations of cobalt, scandium and zinc in lichens and concentrations in air particulate matter and total deposition (wet and dry) were investigated. Chapter 8 describes a laboratory study on the kinetics of the uptake-and release of cadmium in a green algae species (Selenastrum capricornutum Printz), which is regarded to be representative for the algal symboint in the lichens used in this thesis. Chapter 9 presents the central conclusions of this thesis for the lichen species, elements and conditions under study. (orig./MG).

  10. Environmental lichenology: Biomonitoring trace-element air pollution

    International Nuclear Information System (INIS)

    Sloof, J.E.

    1993-01-01

    Chapter 1 describes the possibilities to study trace-element air pollution in order to get insight in the character and element levels of such pollution. Chapter 2 describes two monitoring surveys using Parmelia sulcata Taylor on a national scale, in which spatial and temporal patterns of heavy metals were investigated. The surveys were carried out in 1982-1983 at 110 sampling sites and in 1986-1987 at 210 sampling sites. From these studies it was concluded that lichens are at least good qualitative biomonitors for atmospheric trace-element levels. Chapter 3 describes the response of lichens to the cesium-137 activity as a result of the Chernobyl accident, deposited by rainfall in the Netherlands. From this study it was concluded that lichens are good biomonitors for atmospheric cesium-137 activity too. Chapter 4 describes the application of factor analysis to a lichen data set from a monitoring survey on a national scale (1986-1987), for source apportionment. In Chapter 5 a field study is described on the contribution of a possible influence from the soil to element concentrations in Parmelia sulcata Taylor growing on trees in a an area with polluted soil. Chapter 6 describes a field study on the interchangeability of two tolerant lichen species (Parmelia sulcata Taylor and Lecanora conizaeoides Nyl.) in a polluted area. In Chapter 7 a field study is described in which the quantitative relationships between concentrations of cobalt, scandium and zinc in lichens and concentrations in air particulate matter and total deposition (wet and dry) were investigated. Chapter 8 describes a laboratory study on the kinetics of the uptake-and release of cadmium in a green algae species (Selenastrum capricornutum Printz), which is regarded to be representative for the algal symboint in the lichens used in this thesis. Chapter 9 presents the central conclusions of this thesis for the lichen species, elements and conditions under study. (orig./MG)

  11. Trace element measurement for assessment of dog food safety.

    Science.gov (United States)

    De Nadai Fernandes, Elisabete A; Elias, Camila; Bacchi, Márcio Arruda; Bode, Peter

    2018-01-01

    The quality of dog diets depends on adequate ingredients capable of providing optimal nutrition and free of contaminants, for promoting long-term health. Trace elements in 95 samples of dry food for dog puppies (n = 32) and adults (n = 63) of various brands were measured using instrumental neutron activation analysis (INAA). The mass fractions of most elements were within the permissible limits for dogs. Aluminum, antimony, and uranium presented fairly high levels in some samples, which may imply health risks. Aluminum mass fractions ranged from brand, super-premium dog food. Antimony mass fractions ranged up to 5.14 mg/kg, with the highest values measured in six samples of dog food from the same producer. The mass fractions of uranium was found up to 4 mg/kg in commercial brands from five different producers.

  12. Trace Element Content of Monovarietal and Commercial Portuguese Olive Oils.

    Science.gov (United States)

    Gouvinhas, Irene; Machado, Nelson; Cunha, Maria; Pereira, Marisa; Matos, Carlos; Gomes, Sónia; Lopes, João; Martins-Lopes, Paula; Barros, Ana I R N A

    2015-01-01

    Olive (Olea europaea L.) represents one of the most important and ancient crops in the Mediterranean countries, being widely known due to the optimal organoleptic characteristics of its oil, besides the important health benefits assigned to this product in the last few years. Since olive oil composition, respecting specific trace elements, has a direct impact on the quality and safety of this product, eleven monovarietal and twelve commercial olive oils were analysed spectrometrically concerning their metal composition. Regarding quality parameters, the monovarietal olive oils display larger quantities of Mg, Fe, Mn, while the commercial samples are characterized by greater amounts of Na, Ca, Cu and Zn. In which respects to safety parameters, the commercial samples present higher values for Al and Pb, and lower quantities of Cd, respecting the monovarietal ones. The assessment of the values observed for the trace elements, resorting to multivariate statistical methods, allowed to clearly distinguish the type of olive oil production-monovarietal or commercial blend. For this purpose, besides Cluster analysis, the data have been subjected to Principal Component Analysis-undertaken for either all the evaluated parameters simultaneously, or the quality/safety parameters separately, both data sets allowing the discrimination of the samples.

  13. The separation and determination of trace elements in iron ore

    International Nuclear Information System (INIS)

    Jones, E.A.

    1977-01-01

    The separation, concentration, and determination of trace elements in iron ores are described. After the sample has been dissolved, the iron is separated by liquid-liquid extraction with a liquid cation-exchanger, di-(2-ethylhexyl) phosphoric acid. The trace elements aluminium, cadmium, calcium, chromium, cobalt, copper, lead, magnesium, manganese, mercury, potassium, sodium, vanadium, and zinc are determined in the aqueous phase by atomic-absorption spectrophotometry

  14. K-AR AGES, MINERALOGY, MAJOR AND TRACE ELEMENT ...

    African Journals Online (AJOL)

    The mafic rocks are characterised by high Fe2O3, TiO2, MgO, CaO and variable enrichment in compatible trace elements (Cr, Ni, Co) all of which abruptly decrease with increase in fractionation. Na2O, K2O and Al2O3 and the LILE increase with magma differentiation. Normalised incompatible trace elements show marked ...

  15. Trace elements in shellfish on the Danish market.

    Science.gov (United States)

    Petersen, A; Mortensen, G K

    1994-01-01

    Different kinds of shellfish have been investigated for their contents of the trace elements cadmium, lead, mercury, nickel, chromium, arsenic and selenium. The investigation included shrimps, mussels, lobster, langoustine, crayfish, crab claws and oyster. None of the Danish action levels for cadmium, lead and mercury respectively were exceeded, but the highest concentration of lead was very close to the Danish action levels. Shellfish do not contribute significantly to the intake of the trace elements investigated.

  16. The total trace element content of some Scottish soils by spark source mass spectrometry

    International Nuclear Information System (INIS)

    Ure, A.M.; Bacon, J.R.; Berrow, M.L.; Watt, J.J.

    1979-01-01

    Quantitative methods of analysis by spark source mass spectrometry have been used to determine the total trace element content of the surface horizons of 10 arable Scottish soils derived from parent materials of different geological origin and used for earlier trace element surveys. Other methods have been used to supplement these analyses for 12 elements including the major elements, and results for a total of 62 elements in the 10 soils are reported. The results are discussed in terms of the geological nature of the soil parent material making use of 62-element soil fingerprints for visual comparison. It is concluded that the total trace element contents of a Scottish soil corresponds to that expected on the basis of the geochemistry of its parent materials and that the influence of agricultural operations on soil contents is of secondary importance. Average soil contents for most elements are closely similar to published values for crustal abundance. (Auth.)

  17. Trace elements have limited utility for studying migratory connectivity in shorebirds that winter in Argentina

    Science.gov (United States)

    Torres-Dowdall, J.; Farmer, A.H.; Abril, M.; Bucher, E.H.; Ridley, I.

    2010-01-01

    Trace-element analysis has been suggested as a tool for the study of migratory connectivity because (1) trace-element abundance varies spatially in the environment, (2) trace elements are assimilated into animals' tissues through the diet, and (3) current technology permits the analysis of multiple trace elements in a small tissue sample, allowing the simultaneous exploration of several elements. We explored the potential of trace elements (B, Na, Mg, Al, Si, P, S, K, Ca, Ti, Cr, Mn, Ni, Cu, Zn, As, Sr, Cs, Hg, Tl, Pb, Bi, Th, and U) to clarify the migratory connectivity of shorebirds that breed in North America and winter in southern South America. We collected 66 recently replaced secondary feathers from Red Knots (Calidris canutus) at three sites in Patagonia and 76 from White-rumped Sandpipers (C. fuscicollis) at nine sites across Argentina. There were significant differences in trace-element abundance in shorebird feathers grown at different nonbreeding sites, and annual variability within a site was small compared to variability among sites. Across Argentina, there was no large-scale gradient in trace elements. The lack of such a gradient restricts the application of this technique to questions concerning the origin of shorebirds to a small number of discrete sites. Furthermore, our results including three additional species, the Pectoral Sandpiper (C. melanotos), Wilson's Phalarope (Phalaropus tricolor), and Collared Plover (Charadrius collaris), suggest that trace-element profiles change as feathers age. Temporal instability of trace-element values could undermine their application to the study of migratory connectivity in shorebirds. ?? The Cooper Ornithological Society 2010.

  18. Comparison of leaves of Nerium oleander collected the monitoring trace elements in environmental pollution in Rio de Janeiro and Campinas Cities using of synchrotron radiation fluorescence analysis

    International Nuclear Information System (INIS)

    Simabuco, Silvana M.; Ferreira Pinto, Jefferson; Dos Anjos, Marcelino J.

    1999-01-01

    These works describes the use of synchrotron radiation fluorescence analysis as a technique for monitoring trace elements in bio-indicators for environmental pollution control. The analyses were made on leaves of Nerium oleander collected in streets with different traffic flow in Rio de Janeiro and Campinas Cities, Brazil, with one sample from rural zone. Part of the leaves were cleaned with 0,1% v/v detergent in deionized water and than all were dry at 60o C until constant weight. The leaves were than cut in small pieces and submitted to a nitric digestion in a open system. The liquid residue was pre-concentrated with ammonium pirrrolidine dithiocarbamate and filtrated by vacuum pump in cellulose membrane. The measurement was made with a white beam of synchrotron radiation calibrated with thin film standards. The results indicate that same metals like Ti, V, Fe and Zn have major content in sample that came from places with high traffic flow even in leaves that have been washed. The levels of Mn, Co, Cu and Ni did not show significant difference between the samples. The Pb level also did not vary significantly what was expected because in Brazil the gasoline did not use plumb as a additive from many years. The results seems to indicate that the leaves from Nerium oleander absorb metals from the atmosphere and may be used as one environmental indicator

  19. TRACE ELEMENTS IN FRUIT AND VEGETABLE

    OpenAIRE

    Stefania Papa; Laura Cerullo; Anna Di Monaco; Giovanni Bartoli; Antonietta Fioretto

    2009-01-01

    The concentration of six different trace metals [vanadium (V), nickel (Ni), chromium (Cr),  lead (Pb), copper (Cu) and cadmium (Cd)] were determined in various fruit and vegetables [peach (Prunus persica L.), plum (Prunus domestica L.), tomato (Solanum lycopersicum L.), courgette or marrow (Cucurbita pepo L.) and lettuce (Lactuca sativa L.)] provided by diverse farms. Metal distribution was also separately evaluated, in skin and pulp, where it was possible. Their contributions to human daily ...

  20. Determination of trace elements in cockle Anadara Granosa L. Using INAA.

    Science.gov (United States)

    Ibrahim, N

    1994-08-01

    This study determines the trace metal content in Anadara Granosa L., a popular seafood amongst South-East-Asians. Using the technique of instrumental neutron activation analysis (INAA) identification has been made of the presence of 17 trace metals including elements which are classified as toxic (As, Br, Cs) and those which are rare-earths (Eu, Ce, Lu, Tb, Yb).

  1. Determination of trace elements in cockle Anadara Granosa L. using INAA

    Energy Technology Data Exchange (ETDEWEB)

    Ibrahim, Noorddin (Malaya Univ., Kuala Lumpur (Malaysia). Centre for Foundation Studies in Science)

    1994-08-01

    This study determines the trace metal content in Anadara Granosa L., a popular seafood amongst South-East-Asians. Using the technique of instrumental neutron activation analysis (INAA) identification has been made of the presence of 17 trace metals including elements which are classified as toxic (As, Br, Cs) and those which are rare-earths (Eu, Ce, Lu, Tb, Yb). (author).

  2. New trace element determinations in the fingernails of ALS patients

    Energy Technology Data Exchange (ETDEWEB)

    Van Dalsem, D.J.; Ehmann, W.D. [Univ. of Kentucky, Lexington, KY (United States); Robinson, L. [Oak Ridge National Laboratory, TN (United States)

    1996-12-31

    Amyotrophic lateral sclerosis (ALS) afflicts 2 of every 100,000 people in the United States each year. A well-known example of ALS today is Stephen Hawking. He is a theoretical physicist, the author of A Brief History of Time, and is virtually immobilized by ALS. Diseases that cause progressive paralysis because of motor neuron degeneration in the central nervous system are termed motor neuron disorders (MND). Amyotrophic lateral sclerosis is a common form of MND. Pain-free, progressive muscular weakness is the most common clinical symptom. There is chronic weakness with atrophy of the affected muscles by the time the disease is diagnosed. Atrophy eventually results in wheelchair confinement and then only bed without the ability to speak or swallow. Death often occurs as a result of respiratory problems. Unlike other neurodegenerative diseases, in ALS the patient`s bladder and bowel control, eye movement, and mental faculties are preserved. The question today is whether or not certain trace elements are involved in the etiology or pathogenesis of ALS. A collaborative study was undertaken by the University of Kentucky and Oak Ridge National Laboratory (ORNL) using neutron activation analysis (NAA) to study trace element concentrations in ALS patients fingernails to determine if there existed statistically significant imbalances.

  3. Total reflection X-ray spectrometry (TXRF) for trace elements assessment in edible clams.

    Science.gov (United States)

    Marguí, Eva; de Fátima Marques, Alexandra; de Lurdes Prisal, Maria; Hidalgo, Manuela; Queralt, Ignasi; Carvalho, Maria Luisa

    2014-01-01

    The present contribution presents a preliminary investigation of the chemical composition with respect to major, minor, trace, and ultratrace elements in several clam species that are frequently used for human consumption in Portuguese markets and worldwide. In order to use a simple and rapid analytical methodology for clam analysis, energy dispersive X-ray fluorescence (EDXRF) spectrometry and total reflection X-ray fluorescence (TXRF) spectrometry were selected as analytical techniques. The analytical capabilities of TXRF spectrometry were evaluated for the determination of minor and trace elements in commercial edible clams. We compared the direct analysis of powdered suspensions (using different sample amounts and dispersant agents) with the analysis of the digested samples for trace element determination. Inductively coupled plasma mass spectrometry analysis of clam digests was also performed to evaluate the analytical possibilities of TXRF spectrometry for trace and ultratrace analysis.

  4. The effects of trace element content on pyrite oxidation rates

    Science.gov (United States)

    Gregory, D. D.; Lyons, T.; Cliff, J. B.; Perea, D. E.; Johnson, A.; Romaniello, S. J.; Large, R. R.

    2017-12-01

    Pyrite acts as both an important source and sink for many different metals and metalloids in the environment, including many that are toxic. Oxidation of pyrite can release these elements while at the same time producing significant amounts of sulfuric acid. Such issues are common in the vicinity of abandoned mines and smelters, but, as pyrite is a common accessory mineral in many different lithologies, significant pyrite oxidation can occur whenever pyritic rocks are exposed to oxygenated water or the atmosphere. Accelerated exposure to oxygen can occur during deforestation, fracking for petroleum, and construction projects. Geochemical models for pyrite oxidation can help us develop strategies to mitigate these deleterious effects. An important component of these models is an accurate pyrite oxidation rate; however, current pyrite oxidation rates have been determined using relatively pure pyrite. Natural pyrite is rarely pure and has a wide range of trace element concentrations that may affect the oxidation rate. Furthermore, the position of trace elements within the mineral lattice can also affect the oxidation rate. For example, elements such as Ni and Co, which substitute into the pyrite lattice, are thought to stabilize the lattice and thus prevent pyrite oxidation. Alternatively, trace elements that are held within inclusions of other minerals could form a galvanic cell with the surrounding pyrite, thus enhancing pyrite oxidation rates. In this study, we present preliminary analyses from three different pyrite oxidation experiments each using natural pyrite with different trace element compositions. These results show that the pyrite with the highest trace element concentration has approximately an order of magnitude higher oxidation rate compared to the lowest trace element sample. To further elucidate the mechanisms, we employed microanalytical techniques to investigate how the trace elements are held within the pyrite. LA-ICPMS was used to determine the

  5. X-ray Fluorescence Method for Trace Analysis and Imaging

    OpenAIRE

    Hayakawa, Shinjiro

    2000-01-01

    X-ray fluorescence analysis has a long history as a conventional bulk elemental analysis with medium sensitivity. However, with the use of synchrotron radiation x-ray fluorescence method has become a unique analytical technique which can provide trace elemental information with the spatial resolution. To obtain quantitative information of trace elemental distribution by using the x-ray fluorescence method, theoretical description of x-ray fluorescence yield is described. Moreover, methods and...

  6. Trace Elements in Manganese Minerals as Potential Biosignatures on Mars

    Science.gov (United States)

    Lanza, N.; Clegg, S. M.; Cousin, A.; Forni, O.; Kirk, M. F.; Lamm, S. N.; Ollila, A.; Wiens, R. C.

    2017-12-01

    Observations from the Curiosity rover in Gale crater, Mars have shown the presence of high abundances of manganese (>3 wt% MnO) within sedimentary rocks throughout the traverse. Such high Mn abundances point to the past presence of abundant liquid water and strongly oxidizing conditions. On Earth, these types of environments are almost always habitable and are frequently inhabited by microbes. Given its close association with life and habitable environments on Earth, manganese has long been considered a potential biosignature for Mars. However, high concentrations of martian Mn have only recently been observed. In addition to the observations in Gale crater, high abundances of Mn have also been observed in Endeavor crater by the Opportunity rover and in the paired martian meteorites NWA 7034 and 7533 (`Black Beauty'), suggesting that Mn deposits may be more widespread on Mars than previously thought. The goal of this work is to determine whether there are unique signatures from rover payload instruments that can distinguish Mn-rich deposits as biogenic in origin (i.e., produced by life) from abiogenic Mn deposits. Importantly, Mn-oxides are known to scavenge trace metals from water because of their surface charge properties. We hypothesize that the presence and abundance of specific trace elements are the critical, distinguishing evidence for identifying the biogenic origin of Mn-bearing materials. A suite of natural rocks containing Mn-rich minerals with a range of Mn redox states was selected for analysis with laser-induced breakdown spectroscopy (LIBS). Samples with a biogenic origin had mixed valence redox states between Mn3+ and Mn4+ as inferred by mineralogy. Trace elements Ba, Li, Sr, and Rb were quantified and the presence or absence of Zn and Cu was ascertained by examining key LIBS peaks. Results show that samples with a known microbial origin had moderate Mn abundances >30 wt% MnO and higher Li and Ba. These results suggest that high Mn abundance alone

  7. Major element, trace element, nutrient, and radionuclide mobility in a mining by-product-amended soil.

    Science.gov (United States)

    Douglas, G; Adeney, J; Johnston, K; Wendling, L; Coleman, S

    2012-01-01

    This study investigates the use of a mineral processing by-product, neutralized used acid (NUA), primarily composed of gypsum and Fe-oxyhydroxide, as a soil amendment. A 1489-d turf farm field trial assessed nutrient, trace element, and radionuclide mobility of a soil amended with ∼5% by mass to a depth of 15 cm of NUA. Average PO-P fluxes collected as subsoil leachates were 0.7 and 26.6 kg ha yr for NUA-amended and control sites, respectively, equating to a 97% reduction in PO-P loss after 434 kg P ha was applied. Total nitrogen fluxes in NUA-amended soil leachates were similarly reduced by 82%. Incorporation of NUA conferred major changes in leachate geochemistry with a diverse suite of trace elements depleted within NUA-amended leachates. Gypsum dissolution from NUA resulted in an increase from under- to oversaturation of the soil leachates for a range of Fe- and Ca-minerals including calcite and ferrihydrite, many of which have a well-documented ability to assimilate PO-P and trace elements. Isotopic analysis indicated little Pb addition from NUA. Both Sr and Nd isotope results revealed that NUA and added fertilizer became an important source of Ca to leachate and turf biomass. The NUA-amended soils retained a range of U-Th series radionuclides, with little evidence of transfer to soil leachate or turf biomass. Calculated radioactivity dose rates indicate only a small increment due to NUA amendment. With increased nutrient, trace element, and solute retention, and increased productivity, a range of potential agronomic benefits may be conferred by NUA amendment of soils, in addition to the potential to limit offsite nutrient loss and eutrophication. Copyright © by the American Society of Agronomy, Crop Science Society of America, and Soil Science Society of America, Inc.

  8. Trace elements in human milk. Part of a coordinated programme on comparative methods for the study of trace elements in human nutrition

    International Nuclear Information System (INIS)

    Kosta, L.

    1981-01-01

    New analytical methods based on radiochemical neutron activation analysis were developed for the determination of Sn, V, I and Se at nanogram levels in biological materials, particularly in milk and other foodstuffs. By the application of these and similar methods, results for trace elements in human and cow's milk were collected from which the normal concentration ranges of up to 12 trace elements were established. Significant data on vanadium levels were also collected allowing assessment of the dietary intake and body pool of this element and a reappraisal of its significance in nutrition. Similar data on a smaller scale were also collected for tin. Results were also obtained for several different trace elements in a range of biological reference materials

  9. Sensitivity and accuracy of atomic absorption spectrophotometry for trace elements in marine biological samples

    International Nuclear Information System (INIS)

    Fukai, R.; Oregioni, B.

    1976-01-01

    During the course of 1974-75 atomic absorption spectrophotometry (AAS) has been used extensively in our laboratory for measuring various trace elements in marine biological materials in order to conduct homogeneity tests on the intercalibration samples for trace metal analysis as well as to obtain baseline data for trace elements in various kinds of marine organisms collected from different locations in the Mediterranean Sea. Several series of test experiments have been conducted on the current methodology in use in our laboratory to ensure satisfactory analytical performance in measuring a number of trace elements for which analytical problems have not completely been solved. Sensitivities of the techniques used were repeatedly checked for various elements and the accuracy of the analyses were always critically evaluated by analyzing standard reference materials. The results of these test experiments have uncovered critical points relevant to the application of the AAS to routine analysis

  10. Trace-element content of human scalp hair

    International Nuclear Information System (INIS)

    Gordus, A.A.; Wysocki, C.M.; Maher, C.C. III; Wieland, R.C.

    1974-01-01

    The importance of some of the factors that could affect the measured trace-element content of human scalp hair have been evaluated. Included are frequency of hair washing and swimming, shampoos used, gross differences in diet, and the variation in content along the strands of hair. The data for length-content variation suggest that, for some elements, eccrine sweat may contribute significantly to the measured trace-element content of hair and that such variation must be taken into account in assessing data for historical hair samples, many of which represent clippings of distal segments of hair

  11. Trace elements contents of carbonate sediments from the Mazagan Escarpment off central Morocco (CYAMAZ, 1982)

    OpenAIRE

    Renard, M

    1985-01-01

    Trace element analysis (Mg, Sr, Na, K, Mn, Fe, Ni, Cr, and Zn) of CYAMAZ carbonates shows that a geochemical characterization of platform and post-platform sediments is possible. Platform sediments geochemical study leads to precise the paleoenvironment and shows that late oceanic diagenesis (which take place after subsidence of the platform) does not alter trace element contents of rocks. An attempt of geochemical dating (chemostratigraphy) of post-platform sediments is made.

  12. A search for losses of chromium and other trace elements during lyophilization of human liver tissue

    International Nuclear Information System (INIS)

    Goeij, J.J.M. de; Volkers, K.J.; Tjioe, P.S.

    1979-01-01

    Human liver tissues were investigated for possible trace-element losses during lyophilization by comparison of concentrations of lyophilized and untreated (wet) samples. When destructive neutron activation analysis (n.a.a.) was used, no significant losses were observed for As, Br, Cd, Co, Cr, Cu, Fe, Hg, Mo, Sb, Se, and Zn. The advantages of n.a.a. over radio-tracer techniques for studies of trace-element volatility are discussed. (Auth.)

  13. Study on correlation of trace elements in human hair and internal organs by nuclear methods. A final report of the co-ordinated research programme on the significance of hair mineral analysis as a means for assessing internal body burdens of environmental mineral pollutants. Final report for the period October 1985 - October 1988

    International Nuclear Information System (INIS)

    Cheng Yuandi

    1988-01-01

    Autopsy samples of hair, kidney-cortex, liver and lung were analysed by radiochemical neutron activation analysis to determine the trace elements As, Cd, Hg, Cu and Zn, by instrumental neutron activation analysis to determine the trace elements Se, Na, Mg, Cl, Br, S, Cr, Co, and Rb and by PIXE to determine Fe, Ca and Mn. 15 refs, 22 figs, 10 tabs

  14. Spatial and temporal analysis of the risks posed by total petroleum hydrocarbon and trace element contaminants in coastal waters of Kuwait.

    Science.gov (United States)

    Nicolaus, E E M; Wright, S R; Barry, J; Bolam, T P C; Ghareeb, K; Ghaloom, M; Al-Kanderi, N; Harley, B F M; Le Quesne, W J F; Devlin, M J; Lyons, B P

    2017-07-15

    Nine trace elements including As, Cd, Cu, Fe, Hg, Ni, Pb, V and Zn, and total petroleum hydrocarbons were analysed from water samples collected from 23 stations since 1984 from Kuwaiti coastal waters. Here it was investigated whether concentrations of these determinants are at levels above Kuwaiti and internationally established assessment criteria (AC). The results indicate that Cu and Cd had the most Kuwaiti AC breaches over time. Comparing the data of the last sampled year to the least stringent international AC, then Cu and Cd showed breaches at all stations. The trends for trace metals are significantly downwards, especially for Cd and Hg. No determinant measured showed a significant upward trend, indicating that water pollution for these contaminants is not a worsening situation. However, further sampling should be carried out to confirm these findings, especially at shoreline locations, where routine monitoring ceased in 2011 to investigate any recent changes. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  15. Monitoring of trace element air pollution

    International Nuclear Information System (INIS)

    Freitas, M.C.; Gouveia, M.A.; Prudencio, M.I.; Ferreira, P.; Morgado, I.; Amaro, A.; Fernandes, T.; Dionisio, I.; Reis, M.A.; Alves, L.C.

    1994-01-01

    With this project, a biomonitoring survey will be carried out with epiphytic lichens. The lichens Parmelia sulcata (or caperata) will be collected from olive trees about 1-2 m above the ground, using a 10x10 km grid or 50x50 km gird. In total, about 300 sampling sites will be set up. Within one sampling site, variations in elemental concentrations of lichen material taken from several trees of the same species will be analyzed to obtained the local variation for each element (made in 10% of the grid). In addition some typical soil samples will be collected so that the contribution of soil suspended in air particulate matter can be recognized. The samples will be analyzed for ∼50 elements by NAA and PIXE. The expected results will be integrated data sets, which will be used in the next step for application of a statistical procedure to identify particular pollution sources. The project also consists of exposure experiments with lichen transplant samples at several sampling sites, which are representative for the regions under study. In addition at each sampling site air particular matter and total deposition will be collected monthly, during 1 year. The aim is to establish a quantitative relationship between results obtained with the lichen transplant samples and with air particulate matter and total deposition. (author). 12 refs, 2 figs, 2 tabs

  16. Dispersed particle extraction--a new procedure for trace element enrichment from natural aqueous samples with subsequent ICP-OES analysis.

    Science.gov (United States)

    Bauer, Gerald; Neouze, Marie-Alexandra; Limbeck, Andreas

    2013-01-15

    A novel sample pre-treatment method for multi trace element enrichment from environmental waters prior to optical emission spectrometry analysis with inductively coupled plasma (ICP-OES) is proposed, based on dispersed particle extraction (DPE). This method is based on the use of silica nanoparticles functionalized with strong cation exchange ligands. After separation from the investigated sample solution, the nanoparticles used for the extraction are directly introduced in the ICP for measurement of the adsorbed target analytes. A prerequisite for the successful application of the developed slurry approach is the use of sorbent particles with a mean size of 500 nm instead of commercially available μm sized beads. The proposed method offers the known advantages of common bead-injection (BI) techniques, and further circumvents the elution step required in conventional solid phase extraction procedures. With the use of 14.4 mL sample and addition of ammonium acetate buffer and particle slurry limits of detection (LODs) from 0.03 μg L(-1) for Be to 0.48 μg L(-1) for Fe, with relative standard deviations ranging from 1.7% for Fe and 5.5% for Cr and an average enrichment factor of 10.4 could be achieved. By implementing this method the possibility to access sorbent materials with irreversible bonding mechanisms for sample pre-treatment is established, thus improvements in the selectivity of sample pre-treatment procedures can be achieved. The presented procedure was tested for accuracy with NIST standard reference material 1643e (fresh water) and was applied to drinking water samples from the vicinity of Vienna. Copyright © 2012 Elsevier B.V. All rights reserved.

  17. Postpartum Depression and Role of Serum Trace Elements

    Directory of Open Access Journals (Sweden)

    Mohammad Reza Zarrindast

    2010-06-01

    Full Text Available "nPostpartum depression (PPD is a major depressive disorder that most often emerges within 6 to 12 weeks of delivery, but can happen any time up to 1 year after birth. In developed countries, the incidence of postnatal depression about 10-15% in adult women depending upon the diagnostic criteria, timing of screening and screening instruments used. Mothers with depressive symptoms have been found to have more complex behavioral contacts with their children; this situation can damage family relationships, and even leads to infanticide. Various pathophysiologies are proposed for postpartum depression: Nutritional deficiencies, iron deficiency anemia, rapid decrease in the levels of reproductive hormones following delivery, alterations in hypothalamic-pituitary-adernocortical mechanism and alterations in neurotransmitter levels. Among pathophysiologies of postpartum depression, the role of trace elements is highlighted. The purpose of this review is to assess the role of trace elements including zinc, magnesium, iron and copper PPD. Zinc as a trace element has the second highest concentration of all transition metals in the brain, and its deficiency is associated with behavioral disturbances. Lower zinc blood concentration was found in women with postpartum depression. Another trace element, magnesium, also influences the nervous system via its actions on the release and metabolism of neurotransmitters. Various studies have focused on antidepressant-like effects of magnesium and its deficiency has been reported in depression. Depletion of magnesium stores during pregnancy is hypothesized to be the cause of postpartum depression. Iron deficiency is the most common single nutrient deficiency in the world. There is an association between anemia and depressive disorders. Copper has been recognized as an essential element for many years. Iron also plays a vital role in neurological disorders and its levels are relevant to postpartum depression

  18. Macro-Elements and Trace Elements in Cereal Grains Cultivated in Latvia

    Directory of Open Access Journals (Sweden)

    Jākobsone Ida

    2015-09-01

    Full Text Available Cereal-based foods have great importance in the compensation of micro- and trace element deficiency, because 50% of the foods produced worldwide are made up of cereal grains. The aim of the research was to determine the concentration of macro-elements and trace elements in different cereals cultivated in Latvia. Various cereals were used in the research: rye (n = 45, barley (n = 54, spring wheat (n = 27, winter wheat (n = 53, triticale (n = 45 and oats (n = 42. Thirteen macro- and trace elements (Cd, Pb, Ni, Cr, Al, Cu, K, Na, Mn, Fe, Zn, Mg, Ca were determined in cereal grain samples (n = 266. Macro-elements and trace elements varied significantly (p < 0.01 or p < 0.001. The highest concentrations of macro- and trace elements were found in oats and the lowest in rye. The obtained data will expand the opportunity for food and nutrition scientists to evaluate content of the examined elements in grain products, and dietary consumption (bioavailability of the examined macro-elements and trace elements.

  19. Study of some Ayurvedic Indian medicinal plants for the essential trace elemental contents by instrumental neutron activation analysis and atomic absorption spectroscopy techniques

    International Nuclear Information System (INIS)

    Lokhande, R.S.; Singare, P.U.; Andhele, M.L.; Acharya, R.; Nair, A.G.C.; Reddy, A.V.R.

    2009-01-01

    Elemental analysis of some medicinal plants used in the Indian Ayurvedic system was performed by employing instrumental neutron activation analysis (INAA) and atomic absorption spectroscopy (AAS) techniques. The samples were irradiated with thermal neutrons in a nuclear reactor and the induced activity was counted by gamma ray spectrometry using an efficiency calibrated high resolution high purity germanium (HPGe) detector. Most of the medicinal plants were found to be rich in one or more of the elements under study. The variation in elemental concentration in same medicinal plants samples collected in summer, winter and rainy seasons was studied and the biological effects of these elements on human beings are discussed. (orig.)

  20. Total-reflection X-ray fluorescence studies of trace elements in biomedical samples

    Energy Technology Data Exchange (ETDEWEB)

    Kubala-Kukus, A. [Institute of Physics, Swietokrzyska Academy, Swietokrzyska 15, 25-406 Kielce (Poland)]. E-mail: Aldona.Kubala-Kukus@pu.kielce.pl; Braziewicz, J. [Institute of Physics, Swietokrzyska Academy, Swietokrzyska 15, 25-406 Kielce (Poland); Pajek, M. [Institute of Physics, Swietokrzyska Academy, Swietokrzyska 15, 25-406 Kielce (Poland)

    2004-08-31

    Application of the total-reflection X-ray fluorescence (TXRF) analysis in the studies of trace element contents in biomedical samples is discussed in the following aspects: (i) a nature of trace element concentration distributions, (ii) censoring approach to the detection limits, and (iii) a comparison of two sets of censored data. The paper summarizes the recent results achieved in this topics, in particular, the lognormal, or more general logstable, nature of concentration distribution of trace elements, the random left-censoring and the Kaplan-Meier approach accounting for detection limits and, finally, the application of the logrank test to compare the censored concentrations measured for two groups. These new aspects, which are of importance for applications of the TXRF in different fields, are discussed here in the context of TXRF studies of trace element in various samples of medical interest.

  1. Trace element content of vegetables grown in the victorian goldfields: characterization of a potential hazard

    International Nuclear Information System (INIS)

    Harvey, G.; Dowling, K.; Waldron, H.; Garnett, D.

    2003-01-01

    Plants take-up trace elements essential to healthy growth, but if metal accumulation is excessive, harmful effects are noted in the plant and potentially in the organisms that feed on them. Central Victoria has a rich gold mining heritage, and as such, much of the landscape has been disturbed by the addition of mine waste material, providing an abundant source of metals in a mobile environment. A biogeochemical survey was conducted to evaluate the trace element content of backyard vegetable gardens in the gold field region and the trace element accumulation in commonly grown vegetables. Vegetable (n150) and soil (n59) samples were analysed by instrumental neutron activation analysis. Results indicate that vegetables grown in the central Victorian goldfields have only slightly elevated trace element content. Some exceptions exist, specifically for silverbeet, but the hazard potential is minimal

  2. Characterization of trace element emissions from coal-fired power plants

    International Nuclear Information System (INIS)

    Ondov, J.M.; Ragaini, R.C.; Biermann, A.H.

    1977-01-01

    Samples of suspended particulate material collected in-stack and in the plume at two major Western power plants were analyzed for up to 45 elements using instrumental neutron activation analysis, atomic absorption spectroscopy, and x-ray fluorescence. Enrichments of trace species are compared as a function of particle size from each of the units tested at several distances in the plume. The results of our studies are compared with other trace element studies of coal-fired power plants. Geochemical enrichments of trace elements in coal and enrichment processes occurring during combustion in power plants, and atmospheric transport are discussed. Trace element enrichments in ambient plume aerosols are predicted for an average coal plant. Comparison of the predicted enrichments with mean enrichments of aerosols in 29 cities suggests that coal-fired power plants can be significant sources of Se, As, Mo, W, U, Co, and Ga

  3. Assessment of soil pollution through trace element contamination in a coal mine environment of Jharia

    International Nuclear Information System (INIS)

    Singh, Gurdeep; Shrivastava, B.K.

    1997-01-01

    Coal mining environment is associated with liberation of several trace elements. Soils in such regions particularly have been polluted with these trace elements from a wide range of sources. Trace elements such as lead, copper, iron, zinc, chromium, manganese, cobalt, nickel, cadmium, etc. have caused major human health problems in several parts of the world. Concern over such incidents has prompted numerous investigations into the metabolism and toxic effects of these elements. The trace element contamination of soils (e.g. roadside, overburden dump, residential area etc.) in a part of the Jharia coal field running through a large industrial zone was studied. Representative soil samples from several highly polluted spots of the mining areas were collected and analysed. Results of the investigation revealed that the soils are polluted with trace elements to an appreciable level. Pollution index for soil was developed on the basis of observed concentration levels of trace elements of the study area which may help in better understanding of pollution analysis in coal mining areas. (author)

  4. Determination of trace elements in sedimentary phosphorites with ultraviolet laser ablation ICP-MS

    International Nuclear Information System (INIS)

    Walsh, S.R.

    1999-01-01

    Full text: Analyses of trace elements in sedimentary phosphorites used in fertiliser production are important because many trace elements that are enriched in these rocks can be further enriched during fertiliser production and then transferred to plants and animals. Few detailed studies of trace metals in potential phosphate ores have been published and most published studies involve few samples or present data for a limited range of trace elements. This study uses UV laser ablation ICP-MS with 3mm line burns and calibration against NIST glass standards to provide rapid multi-element analyses of an extensive phosphorite specimen collection from around the world. Because there are no published reports using UV laser ablation to examine phosphorites, no limitations were placed on element combinations during initial multi-element analyses. Selection of up to 30 elements produced unreliable results for a single nodular phosphorite sample compared to data from several other analytical techniques. Results from PIXE analyses were then used for cross-calibration of several major and trace elements determined using UV laser ablation and it was found that three groups of elements need to be analysed separately. Although elements, whether as major or trace elements, within any one group can be determined in any number or combination, elements from other groups cannot be reliably determined at the same time. Group 1 includes any element not in Period 4 of the Periodic Table, the other two groups consist of particular elements from Period 4. Membership of groups is probably related to one or more of the following: 1) saturation of various mass numbers in Period 4 that coincide with argon isotopes, 2) interference from argyles and doubly charged ions that form during analysis from phosphorus, calcium and other light elements in the phosphorites, and 3) the effect of the high energy/frequency UV laser. Raw data are adjusted using results from analytical techniques such as PIXE

  5. Trace element accumulation in Pseudevernia furfuracea (L.) Zopf exposed in Italy's so called Triangle of Death.

    Science.gov (United States)

    Sorbo, S; Aprile, G; Strumia, S; Cobianchi, R Castaldo; Leone, A; Basile, A

    2008-12-15

    Trace element accumulation in the lichen Pseudevernia furfuracea (L.) Zopf was studied in the district of Acerra (province of Naples, southern Italy), one of the points forming Italy's Triangle of Death. P. furfuracea thalli, collected from Mt. Faito (province of Naples), were transplanted and exposed in bags at different sites in Acerra district, classified into three different site types (urban, rural and industrial). We aimed to test the hypothesis that P. furfuracea, when transplanted in the district of Acerra, would respond to air pollution accumulating trace elements and that element concentrations in the exposed lichens were different in relation to the three different environments, characterised by different pollution sources. Samples were exposed for six months, periodically collected and examined by ICP MS spectrometer assays to measure concentrations of 10 trace elements (Al, As, Cd, Cr, Cu, Fe, Mn, Pb, V and Zn). The exposed samples showed increases in concentrations of all the examined elements; the trace element concentrations were evaluated by calculating exposed to control (EC) ratios, for each site and each trace element, to better understand the accumulation rates. EC ratios were evaluated after 3 and 6 month exposures, at the end of spring and summer respectively: 6 month EC values were the highest. The urban sites showed EC ratios generally higher than industrial and rural; the most accumulated elements were Pb and Cu (at the urban sites), Cu and Zn (at the industrial sites), and Cu and As (at the rural sites). The chemical data were then processed using a multivariate approach (ordination, PCA) to better understand environmental gradients. Bioaccumulation data and PCA analysis showed the sampling sites separated by different trace element abundance. Trace element abundance patterns in the three site types are discussed in relation to the land use and the pollution sources.

  6. Chemometric evaluation of trace elements in Brazilian medicinal plants

    International Nuclear Information System (INIS)

    Silva, Paulo S.C. da; Francisconi, Lucilaine S.; Goncalves, Rodolfo D.M.R.

    2013-01-01

    The growing interest in herbal medicines has required standardization in order to ensure their safe use, therapeutic efficacy and quality of the products. Despite the vast flora and the extensive use of medicinal plants by the Brazilian population, scientific studies on the subject are still insufficiency In this study, 59 medicinal plans were analyzed for the determination of As, Ba, Br, Ca, Cl, Cs, Co, Cr, Fe, Hf, K, Mg, Mn, Na, Rb, Sb, Sc, Se, Ta, Th, U, Zn and Zr by neutron activation analysis and Cu, Ni, Pb, Cd and Hg by atomic absorption. The results were analyzed by chemometric methods: correlation analysis, principal component analysis and cluster analysis, in order to verify whether or not there is similarity with respect to their mineral and trace metal contents. Results obtained permitted to classify distinct groups among the analyzed plants and extracts so that these data can be useful in future studies, concerning the therapeutic action the elements here determined may exert. (author)

  7. Determination of rare earth and refractory trace element ...

    Indian Academy of Sciences (India)

    Abundances of rare earth and several other refractory trace elements in a set of early solar system objects isolated from two primitive carbonaceous chondrites were determined using the procedures devised by us. The results suggest that some of these objects could be high temperature nebular condensates, while others ...

  8. Trace element measurement for assessment of dog food safety

    NARCIS (Netherlands)

    Bode, P.; De Nadai Fernandes, E.A.; Elias, Camila; Bacchi, Marcio

    2017-01-01

    The quality of dog diets depends on adequate ingredients capable of providing optimal nutrition and free of contaminants, for promoting long-term health. Trace elements in 95 samples of dry food for dog puppies (n = 32) and adults (n = 63) of various brands were measured using instrumental neutron

  9. Macro and Trace Element Accumulation in Edible Crabs and Frogs ...

    African Journals Online (AJOL)

    The tissue accumulation of five macroelements (Na, Mg, K, Ca, Fe) and twelve trace elements (Vd, Mn, Co, Ni, Cu, Zn, As, Se, Mo, Ag, Cd, Pb) were assessed in the organs of the edible frogs; Xenopus laevis and Rana esculentus, and whole body of the crab, Callinestes caught from Alaro Stream Floodplain (Ibadan, ...

  10. The trace elements in congenital cyanotic heart disease

    Directory of Open Access Journals (Sweden)

    Mohamed Ali Hegazi

    2014-03-01

    Conclusion: Congenital cyanotic heart disease were associated with a highly significant decrease in the mean serum selenium and zinc levels, when compared with control group and non significant increase the mean serum copper levels. Changes in these trace elements suggested to play an important role in the pathogenesis of myocardial damage in congenital cyanotic heart disease.

  11. Effect of soil moisture on trace elements concentrations using

    African Journals Online (AJOL)

    H. Sahraoui and M. Hachicha

    2017-01-01

    Jan 1, 2017 ... ABSTRACT. Portable X-ray fluorescence (PXRF) technology can offer rapid and cost-effective determination of the trace elements concentrations in soils. The aim of this study was to assess the influence of soil moisture content under different condition on PXRF measurement quality. For this purpose ...

  12. Trace Elements Concentrations in Water and Aquatic Biota from Ase ...

    African Journals Online (AJOL)

    MICHAEL HORSFALL

    www.bioline.org.br/ja. Trace Elements Concentrations in Water and Aquatic Biota from Ase Creek in Niger. Delta. OVERAH, C L; *IWEGBUE, C M A; OSSA, E K; NWAJEI, G E. Department of Chemistry, Delta State University, Abraka, Nigeria. ABSTRACT: Water, Tilapia zilli, Synodontis nigrita, Clarias angillaris, Ipomoe cearri ...

  13. Trace Elements Profile among Alcohol Abusers in a Nigerian ...

    African Journals Online (AJOL)

    This showed that Mn, Fe and Cu were significantly increased while Zn was reduced significantly in alcohol abusers when compared with the control group of total abstainers. Excessive consumption of burukutu seems to significantly alter the trace elements status in abusers. Duration of intake and excessive use of burukutu ...

  14. Measurement of trace elements in liver biopsy samples from cattle

    NARCIS (Netherlands)

    Ouweltjes, W.; Zeeuw, de A.C.; Moen, A.; Counotte, G.H.M.

    2007-01-01

    Serum, plasma, or urine samples are usually used for the measurement of the trace elements copper, zinc, iron, selenium, because these samples are easy to obtain; however, these samples are not always appropriate. For example, it is not possible to measure molybdenum, the major antagonist of copper,

  15. Effect of soil moisture on trace elements concentrations using ...

    African Journals Online (AJOL)

    Portable X-ray fluorescence (PXRF) technology can offer rapid and cost-effective determination of the trace elements concentrations in soils. The aim of this study was to assess the influence of soil moisture content under different condition on PXRF measurement quality. For this purpose, PXRF was used to evaluate the soil ...

  16. Trace elements in brazilian soils; Micronutrientes nos solos do Brasil

    Energy Technology Data Exchange (ETDEWEB)

    Rocha, Geraldo Cesar [Juiz de Fora Univ., MG (Brazil). Dept. de Geociencias

    1995-03-01

    A literature revision on trace elements (Zn, B, Mn, Mo, Cu, Fe, and Cl) in Brazilian soils was prepared, with special attention to the chemical form and range in the soil, extraction methods and correlation of the amount in soils with soil properties. 76 refs.

  17. Comparison of trace element contamination levels (Cu, Zn, Fe, Cd ...

    African Journals Online (AJOL)

    Comparison of trace element contamination levels (Cu, Zn, Fe, Cd and Pb) in the soft tissues of the gastropods Tympanotonus fuscatus fuscatus and Tf radula collected in the Ebrié Lagoon (Côte d'Ivoire): Evidence of the risks linked to linked to lead and.

  18. Role of Trace Elements In Diabetes And Hypertension | Odusan ...

    African Journals Online (AJOL)

    Nigerian Endocrine Practice ... Low concentrations and imbalances of certain trace elements occur from poor dietary intake, chronic illnesses,disasters or old age and may result in malfunction of the cardiovascular system, hypertension, arrhythmias andsudden death, or be significantly associated with diabetes. Major role of ...

  19. Trace elements in the kidney tissue of Bluefin Tuna ( Thunnus ...

    African Journals Online (AJOL)

    Trace elements, namely lead (Pb), copper (Cu), manganese (Mn), nickel (Ni), zinc (Zn), and iron (Fe), found in kidney tissues were analyzed and compared between wild/fattened and female/male bluefin tuna (BFT) in the Eastern Mediterranean region of Turkey. One hundred (that is, 50 female and 50 male) individual ...

  20. The EU network on trace element speciation in full swing

    DEFF Research Database (Denmark)

    Cornelis, R.; Camara, C.; Ebdon, L.

    2000-01-01

    The EC-funded thematic network 'Speciation 21' links scientists in analytical chemistry working in method development for the chemical speciation of trace elements, and potential users from industry and representatives of legislative agencies, in the field of environment, food and occupational he...