WorldWideScience

Sample records for totally implantable trans-ventricular

  1. Total Artificial Heart Implantation after Excision of Right Ventricular Angiosarcoma.

    Science.gov (United States)

    Bruckner, Brian A; Abu Saleh, Walid K; Al Jabbari, Odeaa; Copeland, Jack G; Estep, Jerry D; Loebe, Matthias; Reardon, Michael J

    2016-06-01

    Primary cardiac sarcomas, although rare, are aggressive and lethal, requiring thorough surgical resection and adjuvant chemotherapy for the best possible outcome. We report the case of a 32-year-old woman who underwent total artificial heart implantation for right-sided heart failure caused by right ventricular angiosarcoma. For the first several weeks in intensive care, the patient recovered uneventfully. However, a postoperative liver biopsy indicated hepatocellular injury consistent with preoperative chemotherapy. She developed continuing liver failure, from which she died despite good cardiac function.

  2. Effect of right ventricular electrode location (outflow tract vs. apex) on mechanical Ventricular synchrony in patients that underwent pacemaker implant therapy

    International Nuclear Information System (INIS)

    Rincon, Oscar S; Saenz, Luis C; Salazar, Gabriel; Hernandez, Edgar

    2008-01-01

    Objective: to assess in depth the effect of ventricular stimulation from the right ventricular outflow tract and the apex on mechanical ventricular synchrony. Materials And Methods: cohort analytical study. 20 patients with indication of definitive pacemaker indication underwent trans thoracic echocardiogram before and after pacemaker implant with electrode implantation in the right ventricular outflow tract and in the apex (10 patients in each group). There was no structural cardiopathy, ejection fraction was ? 50%, QRS and AV conduction were normal. Mechanical ventricular asynchrony (M mode and tissue doppler) and implant and device parameters were evaluated. Statistical Analysis: results are given as mean values, standard deviation or percentages.Continuous variables were compared using Chi-square test and ANOVA. A p <0.05 value was considered statistically significant. Results: in five patients (25%) a pre-implant ventricular asynchrony was found; in seven (70%) ventricular asynchrony post-implant in the right ventricle outflow tract and in 5 (50%) in the apex. Mean interventricular pot-implant delay was 21,6 ms in the right ventricular outflow tract and 11,5 ms in the apex (p = 0,8); mean septal to lateral wall delay was 73 ms in the right ventricular outflow tract and 26 ms in the apex (p = 0,8). QRS post-implant delay was 134 ms in the right ventricular outflow tract and 140 ms in the apex (p = 0,1). No differences between implant parameters and device programming were found. Conclusions: presence of ventricular asynchrony was evidenced in patients with normal QRS and structurally healthy heart. Ventricular stimulation with pacemaker from the apex or the right ventricular outflow tract suggests acute ventricular asynchrony at least in 60% of the cases, without statistically significant difference between both groups.

  3. Total Artificial Heart Implantation Blood Pressure Management as Resolving Treatment for Massive Hemolysis following Total Artificial Heart Implantation.

    Science.gov (United States)

    Ghodsizad, Ali; Koerner, Michael M; El-Banayosy, A; Zeriouh, Mohamed; Ruhparwar, Arjang; Loebe, Matthias

    2016-10-21

    The SynCardia Total Artificial Heart (TAH) has been used for patients with biventricular failure, who cannot be managed with implantation of a left ventricular (LV) assist device. Following TAH implantation, our patient developed severe hemolysis, which could only be managed successfully by aggressive blood pressure control [Ohashi 2003; Nakata 1998].

  4. Development and evaluation of totally implantable ventricular assist system using a vibrating flow pump and transcutaneous energy transmission system with amorphous fibers.

    Science.gov (United States)

    Yambe, T; Hashimoto, H; Kobayashi, S; Sonobe, T; Naganuma, S; Nanka, S S; Matsuki, H; Yoshizawa, M; Tabayashi, K; Takayasu, H; Takeda, H; Nitta, S

    1997-01-01

    We have developed a vibrating flow pump (VFP) that can generate oscillated blood flow with a relatively high frequency (10-50 Hz) for a totally implantable ventricular assist system (VAS). To evaluate the newly developed VAS, left heart bypasses, using the VFP, were performed in chronic animal experiments. Hemodynamic parameters were recorded in a data recorder in healthy adult goats during an awake condition and analyzed in a personal computer system through an alternating-direct current converter. Basic performance of the total system with a transcutaneous energy transmission system were satisfactory. During left ventricular assistance with the VFP, Mayer wave fluctuations of hemodynamics were decreased in the power spectrum, the fractal dimensions of the hemodynamics were significantly decreased, and peripheral vascular resistance was significantly decreased. These results suggest that cardiovascular regulatory nonlinear dynamics, which mediate the hemodynamics, may be affected by left ventricular bypass with oscillated flow. The decreased power of the Mayer wave in the spectrum caused the limit cycle attractor of the hemodynamics and decreased peripheral resistance. These results suggest that this newly developed VAS is useful for the totally implantable system with unique characteristics that can control hemodynamic properties.

  5. Right ventricular failure after implantation of a continuous-flow left ventricular assist device

    DEFF Research Database (Denmark)

    Cordtz, Johan Joakim; Nilsson, Jens C; Hansen, Peter B

    2014-01-01

    Right ventricular failure (RVF) is a significant complication after implantation of a left ventricular assist device. We aimed to identify haemodynamic changes in the early postoperative phase that predicted subsequent development of RVF in a cohort of HeartMate II (HMII) implanted patients....

  6. Prophylactic implantable defibrillator in patients with arrhythmogenic right ventricular cardiomyopathy/dysplasia and no prior ventricular fibrillation or sustained ventricular tachycardia.

    LENUS (Irish Health Repository)

    Corrado, Domenico

    2010-09-21

    The role of implantable cardioverter-defibrillator (ICD) in patients with arrhythmogenic right ventricular cardiomyopathy\\/dysplasia and no prior ventricular fibrillation (VF) or sustained ventricular tachycardia is an unsolved issue.

  7. Late deterioration of left ventricular function after right ventricular pacemaker implantation.

    Science.gov (United States)

    Bellmann, Barbara; Muntean, Bogdan G; Lin, Tina; Gemein, Christopher; Schmitz, Kathrin; Schauerte, Patrick

    2016-09-01

    Right ventricular (RV) pacing induces a left bundle branch block pattern on ECG and may promote heart failure. Patients with dual chamber pacemakers (DCPs) who present with progressive reduction in left ventricular ejection fraction (LVEF) secondary to RV pacing are candidates for cardiac resynchronization therapy (CRT). This study analyzes whether upgrading DCP to CRT with the additional implantation of a left ventricular (LV) lead improves LV function in patients with reduced LVEF following DCP implantation. Twenty-two patients (13 males) implanted with DCPs and a high RV pacing percentage (>90%) were evaluated in term of new-onset heart failure symptoms. The patients were enrolled in this retrospective single-center study after obvious causes for a reduced LVEF were excluded with echocardiography and coronary angiography. In all patients, DCPs were then upgraded to biventricular devices. LVEF was analyzed with a two-sided t-test. QRS duration and brain natriuretic peptide (BNP) levels were analyzed with the unpaired t-test. LVEF declined after DCP implantation from 54±10% to 31±7%, and the mean QRS duration was 161±20 ms during RV pacing. NT-pro BNP levels were elevated (3365±11436 pmol/L). After upgrading to a biventricular device, a biventricular pacing percentage of 98.1±2% was achieved. QRS duration decreased to 108±16 ms and 106±20 ms after 1 and 6 months, respectively. There was a significant increase in LVEF to 38±8% and 41±11% and a decrease in NT-pro BNP levels to 3088±2326 pmol/L and 1860±1838 pmol/L at 1 and 6 months, respectively. Upgrading to CRT may be beneficial in patients with DCPs and heart failure induced by a high RV pacing percentage.

  8. Perioperative management of calves undergoing implantation of a left ventricular assist device.

    Science.gov (United States)

    Wilson, D V; Kantrowitz, A; Pacholewicz, J; Salat, O; Paules, B R; Zhou, Y; Dawe, E J

    2000-01-01

    To describe perioperative management of calves that underwent left lateral thoracotomy, aortic cross-clamping, partial left heart bypass and implantation of a left ventricular assist device. A total of 43 healthy castrated male calves, weighing 121 +/- 24 kg. Diazepam (mean +/- SD, 0.26 +/- 0.07 mg/kg), ketamine (5.9 +/- 2.17 mg/kg) and isoflurane were used in the anesthetic management of calves undergoing implantation of a left ventricular assist device in the descending thoracic aorta. Other adjunctive agents administered were fentanyl (11 +/- 5.4 microg/kg), lidocaine (4.9 +/- 3.19 mg/kg), bupivacaine (0.75%) and butorphanol (0.49 +/- 0.13 mg/kg). None of the calves regurgitated at induction or during intubation. A tube was used to drain the rumen and prevent bloat during the procedure. Partial left heart bypass was used to perfuse the caudal half of the body during the period of aortic cross clamp and device implantation. Initial mean systemic blood pressure was 96 +/- 25 mm Hg, and pressures measured in the auricular artery increased during aortic cross-clamping and bypass. Vasoconstrictor therapy was required to treat caudal arterial hypotension during the procedure in 9 calves. Mean systemic arterial pressures returned to baseline values by the end of the anesthetic period. Initial mean pulmonary arterial pressures (PAP) were 22 +/- 3 mm Hg. A significant but transient increase in pulmonary arterial pressure occurred after both heparin and protamine administration. The described anesthetic protocol was effective for thoracotomy and implantation of an intra-aortic left ventricular assist device in normal calves. Partial left ventricular bypass was a useful adjunct during the period of aortic cross clamp. The doses of heparin and protamine administered were effective. Responsibility to monitor oxygenation of the cranial half of the animal continues during the bypass period as hypoxemia due to pulmonary dysfunction will not be detected by the perfusionist.

  9. Intraoperative Transesophageal Echocardiography and Right Ventricular Failure After Left Ventricular Assist Device Implantation.

    Science.gov (United States)

    Silverton, Natalie A; Patel, Ravi; Zimmerman, Josh; Ma, Jianing; Stoddard, Greg; Selzman, Craig; Morrissey, Candice K

    2018-02-15

    To determine whether intraoperative measures of right ventricular (RV) function using transesophageal echocardiography are associated with subsequent RV failure after left ventricular assist device (LVAD) implantation. Retrospective, nonrandomized, observational study. Single tertiary-level, university-affiliated hospital. The study comprised 100 patients with systolic heart failure undergoing elective LVAD implantation. Transesophageal echocardiographic images before and after cardiopulmonary bypass were analyzed to quantify RV function using tricuspid annular plane systolic excursion (TAPSE), tricuspid annular systolic velocity (S'), fractional area change (FAC), RV global longitudinal strain, and RV free wall strain. A chart review was performed to determine which patients subsequently developed RV failure (right ventricular assist device placement or prolonged inotrope requirement ≥14 days). Nineteen patients (19%) subsequently developed RV failure. Postbypass FAC was the only measure of RV function that distinguished between the RV failure and non-RV failure groups (21.2% v 26.5%; p = 0.04). The sensitivity, specificity, and area under the curve of an abnormal RV FAC (failure after LVAD implantation were 84%, 20%, and 0.52, respectively. No other intraoperative measure of RV function was associated with subsequent RV failure. RV failure increased ventilator time, intensive care unit and hospital length of stay, and mortality. Intraoperative measures of RV function such as tricuspid annular plane systolic excursion, tricuspid annular systolic velocity, and RV strain were not associated with RV failure after LVAD implantation. Decreased postbypass FAC was significantly associated with RV failure but showed poor discrimination. Copyright © 2018 Elsevier Inc. All rights reserved.

  10. Terapia de resincronización con implante de electrodo ventricular izquierdo por vía epicárdica Resynchronization therapy with left ventricular electrode implant via epicardium

    Directory of Open Access Journals (Sweden)

    Francisco Gómez

    2007-12-01

    Full Text Available Introducción: la terapia de resincronización cardiaca es segura y efectiva para mejorar la clase funcional y la calidad de vida, y reducir la mortalidad en pacientes con falla cardiaca en estado funcional III y IV con terapia médica óptima. Métodos: este es el reporte del procedimiento realizado a un grupo de pacientes a quienes se les implantó un marcapasos tricameral para resincronización cardiaca, con inserción del electrodo ventricular izquierdo por vía epicárdica, realizado en la Unidad Cardiovascular y de Trasplantes del Hospital Universitario San Vicente de Paúl y la Universidad de Antioquia, en noviembre de 2004 a febrero de 2006. Los pacientes elegidos para la inserción cumplían con los criterios de falla cardiaca estadio C o D, según la clasificación de la NYHA III ó IV, corroborado con prueba funcional menor de 5 MET, fracción de eyección menor del 35%, QRS mayor de 120 milisegundos y criterios ecocardiográficos de disincronía intraventricular, interventricular o aurículo-ventricular. Resultados: se incluyeron nueve pacientes: cinco hombres y cuatro mujeres, con edad promedio de 57 años; ocho pacientes tenían bloqueo de rama izquierda del haz de His. El procedimiento de implante se realizó en dos tiempos, el primero en la sala de hemodinámica donde se ubicó el electrodo de aurícula derecha y ventrículo derecho, y el segundo en el quirófano, donde se puso un electrodo del ventrículo izquierdo por vía epicárdica por minitoracotomía anterior izquierda. El tiempo total del procedimiento osciló entre 35 a 210 minutos con un promedio de 105 minutos, menor en los últimos pacientes. Las medidas intraoperatorias demuestran un umbral de estimulación promedio de 0,9 mv; la duración del QRS fue menor a 130 milisegundos luego de la estimulación biventricular en el 100% de los casos y el tiempo de detección al estimular con el electrodo ventricular izquierdo, fue mayor de 100 milisegundos en el 100% de los

  11. Efecto de la localización del electrodo ventricular derecho (tracto de salida vs. ápex sobre la sincronía ventricular mecánica, en pacientes sometidos a terapia de implante de marcapaso cardiaco Effect of right ventricular electrode location (outflow tract vs. apex on mechanical ventricular synchrony in patients that underwent pacemaker implant therapy

    Directory of Open Access Journals (Sweden)

    Oscar S Rincón

    2008-12-01

    Full Text Available Objetivo: evaluar a profundidad el efecto de la estimulación ventricular desde el tracto de salida del ventrículo derecho y el ápex, sobre la sincronía ventricular mecánica. Materiales y métodos: estudio analítico de cohorte, en el que se realizó ecocardiograma transtorácico pre y post implante de marcapaso a 20 pacientes (diez por cada grupo con indicación de marcapaso definitivo, con implante del electrodo en el tracto de salida del ventrículo derecho y el ápex, sin cardiopatía estructural, fracción de eyección > 50%; QRS y conducción aurículo-ventricular normal, con el fin de evaluar la asincronía ventricular mecánica (modo M y Doppler tisular y los parámetros de implante y programación del dispositivo. Análisis estadístico: los resultados se presentan como promedios, desviación estándar o porcentajes. Las variables continuas se compararon utilizando prueba Chi cuadrado y ANOVA. Se consideró como estadísticamente significativa una p Objective: to assess in depth the effect of ventricular stimulation from the right ventricular outflow tract and the apex on mechanical ventricular synchrony. Materials and Methods: cohort analytical study. 20 patients with indication of definitive pacemaker indication underwent transthoracic echocardiogram before and after pacemaker implant with electrode implantation in the right ventricular outflow tract and in the apex (10 patients in each group. There was no structural cardiopathy, ejection fraction was > 50%, QRS and AV conduction were normal. Mechanical ventricular asynchrony (M mode and tissue doppler and implant and device parameters were evaluated. Statistical Analysis: results are given as mean values, standard deviation or percentages. Continuous variables were compared using Chi-square test and ANOVA. A p <0.05 value was considered statistically significant. Results: in five patients (25% a pre-implant ventricular asynchrony was found; in seven (70% ventricular asynchrony

  12. Inhaled Milrinone After Left Ventricular Assist Device Implantation.

    Science.gov (United States)

    Haglund, Nicholas A; Burdorf, Adam; Jones, Tara; Shostrom, Valerie; Um, John; Ryan, Timothy; Shillcutt, Sasha; Fischer, Patricia; Cox, Zachary L; Raichlin, Eugenia; Anderson, Daniel R; Lowes, Brian D; Dumitru, Ioana

    2015-10-01

    Proven strategies to reduce right ventricular (RV) dysfunction after continuous-flow left ventricular assist device (CF-LVAD) implantation are lacking. We sought to evaluate the tolerability, feasibility, efficacy, and pharmacokinetics of inhaled milrinone (iMil) delivery after CF-LVAD implantation. We prospectively evaluated fixed-dose nebulized iMil delivered into a ventilator circuit for 24 hours in 10 postoperative CF-LVAD (Heartmate-II) patients. Tolerability (arrhythmias, hypotension, and hypersensitivity reaction), efficacy (hemodynamics), pharmacokinetics (plasma milrinone levels), and cost data were collected.Mean age was 56 ± 9 years, 90% were male, and mean INTERMACS profile was 2.5 ± 0.8. No new atrial arrhythmia events occurred, although 3 (30%) ventricular tachycardia (1 nonsustained, 2 sustained) events occurred. Sustained hypotension, drug hypersensitivity, death, or need for right ventricular assist device were not observed. Invasive mean pulmonary arterial pressure from baseline to during iMil therapy was improved (P = .017). Mean plasma milrinone levels (ng/mL) at baseline, and 1, 4, 8, 12, and 24 hours were 74.2 ± 35.4, 111.3 ± 70.9, 135.9 ± 41.5, 205.0 ± 86.7, 176.8 ± 61.3 187.6 ± 105.5, respectively. Reduced institutional cost was observed when iMil was compared with nitric oxide therapy over 24 hours ($165.29 vs $1,944.00, respectively). iMil delivery after CF-LVAD implantation was well tolerated, feasible, and demonstrated favorable hemodynamic, pharmacokinetic, and cost profiles. iMil therapy warrants further study in larger clinical trials. Copyright © 2015 Elsevier Inc. All rights reserved.

  13. Percutaneous Repair of Postoperative Mitral Regurgitation After Left Ventricular Assist Device Implant.

    Science.gov (United States)

    Cork, David P; Adamson, Robert; Gollapudi, Raghava; Dembitsky, Walter; Jaski, Brian

    2018-02-01

    Mitral regurgitation commonly improves after implantation of a left ventricular assist device without concomitant valvular repair owing to the mechanical unloading of the left ventricle. However, the development (or persistence) of significant mitral regurgitation after implantation of a left ventricular assist device is associated with adverse clinical events. We present a case of a left ventricular assist device patient who successfully underwent a percutaneous MitraClip procedure for repair of persistent late postoperative mitral insufficiency with demonstrable clinical and hemodynamic improvement. Copyright © 2018 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  14. Hemodynamic deterioration precedes onset of ventricular tachyarrhythmia after Heartmate II implantation.

    Science.gov (United States)

    Yaksh, Ameeta; Kik, Charles; Knops, Paul; Zwiers, Korinne; van Ettinger, Maarten J B; Manintveld, Olivier C; de Wijs, Marcel C J; van der Kemp, Peter; Bogers, Ad J J C; de Groot, Natasja M S

    2016-07-08

    Early postoperative ventricular tachyarrhythmia (PoVT) after left ventricular assist device (LVAD) implantation are common and associated with higher mortality-rates. At present, there is no data on initiation of these PoVT and the role of alterations in cardiac hemodynamics. A LVAD was implanted in a patient with end-stage heart failure due to a ischemic cardiomyopathy. Alterations in cardiac rhythm and hemodynamics preceding PoVT-episodes during the first five postoperative days were examined by using continuous recordings of cardiac rhythm and various hemodynamic parameters. All PoVT (N=120) were monomorphic, most often preceded by short-long-short-sequences or regular SR and initiated by ventricular runs. Prior to PoVT, mean arterial pressure decreased; heart rate and ST-segments deviations increased. PoVT are caused by different underlying electrophysiological mechanisms. Yet, they are all monomorphic and preceded by hemodynamic deterioration due to myocardial ischemia.

  15. Patient-prosthesis mismatch and left ventricular remodelling after implantation of Shelhigh SuperStentless aortic valve prostheses.

    Science.gov (United States)

    Germing, A; Lindstaedt, M; Holt, S; Reber, D; Mügge, A; Laczkovics, A; Fritz, M

    2008-08-01

    Aortic valve replacement is a standard procedure for the treatment of severe aortic valve stenosis. Due to lower flow velocities stentless valves are associated with a more effective regression of left ventricular hypertrophy in comparison to stented valves. However, mismatch between body surface area and valve size supports unfavourable hemodynamic results. The aim of the study was to analyze hemodynamic parameters by echocardiography after implantation of the Shelhigh SuperStentless bioprosthesis and to analyze the occurrence of patient-prosthesis mismatch and left ventricular remodelling in this specific valve type. A total of 20 patients with severe aortic stenosis underwent implantation of a Shelhigh Super Stentless prosthesis. Clinical and echocardiographic assessment was done prior to, immediate after and six months after surgery. All surgical procedures were successful, no surgery-related complication was documented perioperatively. One patient died after development of multiorgan failure. Echocardiography during the first eight days after surgery showed mean gradients of 16 mmHg, mean valve orifice areas of 1.8 cm(2) and indexed effective orifice areas at 0.95 cm(2)/m(2). Six-months follow-up data were obtained in 19/20 patients. There were no relevant changes in echocardiographic hemodynamic findings at the time of follow-up measurements. Significant regression of left ventricular hypertrophy was shown (P=0.0088). A patient-prosthesis mismatch occurred in one patient (0.54 cm(2)/m(2)). No recurrent symptoms were documented. Patient-prosthesis mismatch after implantation of SuperStentless Shelhigh prosthesis is rare. A significant regression of left ventricular hypertrophy could be shown after six months. Hemodynamic valve function assessed by echocardiography may be predicted early after surgery.

  16. Anxiety and risk of ventricular arrhythmias or mortality in patients with an implantable cardioverter defibrillator

    DEFF Research Database (Denmark)

    Habibović, Mirela; Pedersen, Susanne S.; van den Broek, Krista C

    2013-01-01

    A subgroup of patients with an implantable cardioverter defibrillator (ICD) experiences anxiety after device implantation. The purpose of the present study was to evaluate whether anxiety is predictive of ventricular arrhythmias and all-cause mortality 1 year post ICD implantation....

  17. Neuroendoscopic Trans-Third Ventricular Approach for Surgical Management of Ecchordosis Physaliphora.

    Science.gov (United States)

    Adib, Sasan Darius; Bisdas, Sotirios; Bornemann, Antje; Schuhmann, Martin U

    2016-06-01

    We sought to report the successful surgical management of a case of ecchordosis physaliphora (EP) using a neuro-endoscopic trans-third ventricular approach (ETTVA) and to provide a current review of literature on EP. A 57-year-old man presenting with a 2-year history of diplopia due to right abducens nerve palsy and paresthesia of the left body underwent magnetic resonance imaging, which revealed a retroclival intracisternal lesion. The cystic lesion was considered to be most likely EP according to neuroradiologic features. The patient underwent an endoscopic trans-third ventricular resection. A pediatric endoscope was passed from a precoronal burr hole through the left lateral into the third ventricle. The floor of the third ventricle was opened by a 2-micron laser. This approach permitted us to expose the lesion in the retroclival cistern and follow up with a subtotal removal. Remnants of the capsule, which were firmly adherent to small pontine arteries and the left abducens nerve, were left. Histology confirmed EP. The patient recovered well from surgery, and symptoms regressed at clinical follow-up. The endoscopic approach for third ventriculostomy can also be used for the surgical management of retroclival lesions. However, a small pediatric endoscope with an angled view, which can be passed through the floor of the third ventricle without causing harm, is mandatory to explore all important structures in the narrow surgical space. Limitations in this delicate environment are firm adhesions to vessels and nerves because only 1-instrument manipulation is possible and bleeding must be avoided. Copyright © 2016 Elsevier Inc. All rights reserved.

  18. Trans-apical aortic valve implantation in a patient with stentless valve degeneration.

    Science.gov (United States)

    Kapetanakis, Emmanouil I; MacCarthy, Philip; Monaghan, Mark; Wendler, Olaf

    2011-06-01

    Trans-apical valve-in-valve trans-catheter aortic valve implantation (TAVI) has successfully been performed in selected, high-risk patients, who suffered prosthetic degeneration after aortic valve replacement using stented xenografts. We report the case of a 79-year-old male patient who underwent one of the first successful TAVIs in a failing stentless bioprosthesis. Copyright © 2010 European Association for Cardio-Thoracic Surgery. Published by Elsevier B.V. All rights reserved.

  19. Prospective Randomized Evaluation of Implantable Cardioverter-Defibrillator Programming in Patients With a Left Ventricular Assist Device.

    Science.gov (United States)

    Richardson, Travis D; Hale, Leslie; Arteaga, Christopher; Xu, Meng; Keebler, Mary; Schlendorf, Kelly; Danter, Matthew; Shah, Ashish; Lindenfeld, JoAnn; Ellis, Christopher R

    2018-02-23

    Ventricular arrhythmias are common in patients with left ventricular assist devices (LVADs) but are often hemodynamically tolerated. Optimal implantable cardioverter defibrillator (ICD) tachy-programming strategies in patients with LVAD have not been determined. We sought to determine if an ultra-conservative ICD programming strategy in patients with LVAD affects ICD shocks. Adult patients with an existing ICD undergoing continuous flow LVAD implantation were randomized to standard ICD programming by their treating physician or an ultra-conservative ICD programming strategy utilizing maximal allowable intervals to detection in the ventricular fibrillation and ventricular tachycardia zones with use of ATP. Patients with cardiac resynchronization therapy (CRT) devices were also randomized to CRT ON or OFF. Patients were followed a minimum of 6 months. The primary outcome was time to first ICD shock. Among the 83 patients studied, we found no statistically significant difference in time to first ICD shock or total ICD shocks between groups. In the ultra-conservative group 16% of patients experienced at least one shock compared with 21% in the control group ( P =0.66). There was no difference in mortality, arrhythmic hospitalization, or hospitalization for heart failure. In the 41 patients with CRT ICDs fewer shocks were observed with CRT-ON but this was not statistically significant: 10% of patients with CRT-ON (n=21) versus 38% with CRT-OFF (n=20) received shocks ( P =0.08). An ultra-conservative programming strategy did not reduce ICD shocks. Programming restrictions on ventricular tachycardia and ventricular fibrillation zone therapy should be reconsidered for the LVAD population. The role of CRT in patients with LVAD warrants further investigation. URL: https://www.clinicaltrials.gov. Unique identifier: NCT01977703. © 2018 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.

  20. Calculation of the ALMA Risk of Right Ventricular Failure After Left Ventricular Assist Device Implantation.

    Science.gov (United States)

    Loforte, Antonio; Montalto, Andrea; Musumeci, Francesco; Amarelli, Cristiano; Mariani, Carlo; Polizzi, Vincenzo; Lilla Della Monica, Paola; Grigioni, Francesco; Di Bartolomeo, Roberto; Marinelli, Giuseppe

    2018-05-08

    Right ventricular failure after continuous-flow left ventricular assist device (LVAD) implantation is still an unsolved issue and remains a life-threatening event for patients. We undertook this study to determine predictors of the patients who are candidates for isolated LVAD therapy as opposed to biventricular support (BVAD). We reviewed demographic, echocardiographic, hemodynamic, and laboratory variables for 258 patients who underwent both isolated LVAD implantation and unplanned BVAD because of early right ventricular failure after LVAD insertion, between 2006 and 2017 (LVAD = 170 and BVAD = 88). The final study patients were randomly divided into derivation (79.8%, n = 206) and validation (20.1%, n = 52) cohorts. Fifty-seven preoperative risk factors were compared between patients who were successfully managed with an LVAD and those who required a BVAD. Nineteen variables demonstrated statistical significance on univariable analysis. Multivariable logistic regression analysis identified destination therapy (odds ratio [OR] 2.0 [1.7-3.9], p = 0.003), a pulmonary artery pulsatility index right ventricle/left ventricle end-diastolic diameter ratio >0.75 (OR 2.7 [1.5-5.5], p = 0.001), an right ventricle stroke work index 17 (OR 3.5 [1.9-6.9], p the major predictors of the need for BVAD. Using these data, we propose a simple risk calculator to determine the suitability of patients for isolated LVAD support in the era of continuous-flow mechanical circulatory support devices.

  1. Successful Implantation of a Left Ventricular Assist Device After Treatment With the Paracor HeartNet.

    Science.gov (United States)

    Schweiger, Martin; Stepanenko, Alexander; Potapov, Evgenji; Drews, Thorsten; Hetzer, Roland; Krabatsch, Thomas

    2010-01-01

    The Paracor HeartNet, a ventricular constraint device for the treatment of heart failure (HF), is implanted through a left lateral thoracotomy. It envelopes the heart like a mesh "bag." This method of application raises the question of whether adhesions with the pericardium allow the safe implantation of a left ventricular assist device (LVAD) if HF worsens. A male patient who had undergone implantation of the Paracor HeartNet 42 months earlier presented with advanced HF for cardiac transplantation. The patient's condition deteriorated, and because no suitable organ for transplantation was available, implantation of an LVAD became necessary. Surgery was performed via a median sternotomy without complications. No severe adhesions were found. This is the first report on "how to do" LVAD implantation after Paracor HeartNet implantation with images and information about cutting the constraint. Because the Paracor HeartNet is "wrapped" around the heart, concerns persist that severe adhesions with the pericardium might occur. In this case, LVAD implantation after therapy with the Paracor HeartNet was without complications, and the expected massive adhesions were absent.

  2. Using left-ventricular-only pacing to eliminate T-wave oversensing in a biventricular implantable cardiac defibrillator.

    Science.gov (United States)

    Khoo, Clarence; Bennett, Matthew; Chakrabarti, Santabhanu; LeMaitre, John; Tung, Stanley K K

    2013-02-01

    A man aged 75 years and with nonischemic cardiomyopathy had implantation of a biventricular implantable cardiac defibrillator (ICD). Consistent biventricular pacing was limited by intermittent T-wave oversensing (TWOS). A strategy of left-ventricular-only pacing was used to eliminate TWOS. This strategy obviates the need to reduce ventricular sensitivity and thus may be an effective alternative to biventricular pacing complicated by TWOS. Copyright © 2013 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.

  3. Ventricular Tachyarrhythmias and Mortality in Patients With an Implantable Cardioverter Defibrillator

    DEFF Research Database (Denmark)

    Mastenbroek, Mirjam H; Versteeg, Henneke; Jordaens, Luc

    2014-01-01

    Objective We examined whether depression is independently associated with implantable cardioverter defibrillator (ICD) therapy for ventricular tachyarrhythmias and mortality. Methods A cohort of 430 consecutive patients with a first-time ICD (79% men; mean [standard deviation] age = 57.8 [12.1] y...

  4. Ventricular fibrillation induced by coagulating mode bipolar electrocautery during pacemaker implantation in Myotonic Dystrophy type 1 patient.

    Science.gov (United States)

    Russo, Vincenzo; Rago, Anna; DI Meo, Federica; Cioppa, Nadia Della; Papa, Andrea Antonio; Russo, Maria Giovanna; Nigro, Gerardo

    2014-12-01

    The occurrence of ventricular fibrillation, induced by bipolar electrocautery during elective dual chamber pacemaker implantation, is reported in a patient affected by Myotonic Distrophy type 1 with normal left ventricular ejection fraction.

  5. [Implantable sensors for outpatient assessment of ventricular filling pressure in advanced heart failure : Which telemonitoring design is optimal?

    Science.gov (United States)

    Herrmann, E; Fichtlscherer, S; Hohnloser, S H; Zeiher, A M; Aßmus, B

    2016-12-01

    Patients with advanced heart failure suffer from frequent hospitalizations. Non-invasive hemodynamic telemonitoring for assessment of ventricular filling pressure has been shown to reduce hospitalizations. We report on the right ventricular (RVP), the pulmonary artery (PAP) and the left atrial pressure (LAP) sensor for non-invasive assessment of the ventricular filling pressure. A literature search concerning the available implantable pressure sensors for noninvasive haemodynamic telemonitoring in patients with advanced heart failure was performed. Until now, only implantation of the PAP-sensor was able to reduce hospitalizations for cardiac decompensation and to improve quality of life. The right ventricular pressure sensor missed the primary endpoint of a significant reduction of hospitalizations, clinical data using the left atrial pressure sensor are still pending. The implantation of a pressure sensor for assessment of pulmonary artery filling pressure is suitable for reducing hospitalizations for heart failure and for improving quality of life in patients with advanced heart failure.

  6. Our experience with implantation of VentrAssist left ventricular assist device

    Directory of Open Access Journals (Sweden)

    Hiriyur Shivalingappa Jayanthkumar

    2013-01-01

    Full Text Available Perioperative anaesthetic management of the VentrAssist TM left ventricular assist device (LVAD is a challenge for anaesthesiologists because patients presenting for this operation have long-standing cardiac failure and often have associated hepatic and renal impairment, which may significantly alter the pharmacokinetics of administered drugs and render the patients coagulopathic. The VentrAssist is implanted by midline sternotomy. A brief period of cardiopulmonary bypass (CPB for apical cannulation of left ventricle is needed. The centrifugal pump, which produces non-pulsatile, continuous flow, is positioned in the left sub-diaphragmatic pocket. This LVAD is preload dependent and afterload sensitive. Transoesophageal echocardiography is an essential tool to rule out contraindications and to ensure proper inflow cannula position, and following the implantation of LVAD, to ensure right ventricular (RV function. The anaesthesiologist should be prepared to manage cardiac decompensation and acute desaturation before initiation of CPB, as well as RV failure and severe coagulopathic bleeding after CPB. Three patients had undergone implantation of VentrAssist in our hospital. This pump provides flow of 5 l/min depending on preload, afterload and pump speed. All the patients were discharged after an average of 30 days. There was no perioperative mortality.

  7. New method for cardiac resynchronization therapy: Transapical endocardial lead implantation for left ventricular free wall pacing

    NARCIS (Netherlands)

    I. Kassai (Imre); C. Foldesi (Csaba); A. Szekely (Andrea); T. Szili-Torok (Tamas)

    2008-01-01

    textabstractCoronary sinus lead placement for transvenous left ventricular (LV) pacing in cardiac resynchronization therapy (CRT) has a significant failure rate at implant and a significant dislocation rate during follow-up. For these patients, epicardial pacing lead implantation is the most

  8. Total artificial heart implantation for biventricular failure due to eosinophilic myocarditis.

    Science.gov (United States)

    Kawabori, Masashi; Kurihara, Chitaru; Miller, Yair; Heck, Kent A; Bogaev, Roberta C; Civitello, Andrew B; Cohn, William E; Frazier, O H; Morgan, Jeffrey A

    2017-09-01

    Idiopathic hypereosinophilic syndrome is a condition of unknown etiology characterized by proliferation of eosinophils and their infiltration into tissues. Although cardiac involvement is rare, eosinophilic myocarditis can lead to life-threating fulminant congestive heart failure. Treatment of patients with eosinophilic myocarditis is challenging as heart failure can be caused by biventricular dysfunction. To our knowledge, this is the first case reported in the literature describing a patient with acute severe biventricular heart failure caused by eosinophilic myocarditis with mural left ventricular apical thrombus who was successfully treated with implantation of a total artificial heart as a bridge to heart transplant.

  9. Relation between total shock energy and mortality in patients with implantable cardioverter-defibrillator.

    Science.gov (United States)

    Tenma, Taro; Yokoshiki, Hisashi; Mitsuyama, Hirofumi; Watanabe, Masaya; Mizukami, Kazuya; Kamada, Rui; Takahashi, Masayuki; Sasaki, Ryo; Maeno, Motoki; Okamoto, Kaori; Chiba, Yuki; Anzai, Toshihisa

    2018-05-15

    Implantable Cardioverter-Defibrillator (ICD) shocks have been associated with mortality. However, no study has examined the relation between total shock energy and mortality. The aim of this study is to assess the association of total shock energy with mortality, and to determine the patients who are at risk of this association. Data from 316 consecutive patients who underwent initial ICD implantation in our hospital between 2000 and 2011 were retrospectively studied. We collected shock energy for 3 years from the ICD implantation, and determined the relation of shock energy on mortality after adjusting confounding factors. Eighty-seven ICD recipients experienced shock(s) within 3 years from ICD implantation and 43 patients had died during the follow-up. The amount of shock energy was significantly associated with all-cause death [adjusted hazard ratio (HR) 1.26 (per 100 joule increase), p energy accumulation (≥182 joule) was lower (p energy accumulation (energy accumulation and all-cause death was remarkable in the patients with low left ventricular ejection fraction (LVEF ≤40%) or atrial fibrillation (AF). Increase of shock energy was related to mortality in ICD recipients. This relation was evident in patients with low LVEF or AF. Copyright © 2018 Elsevier B.V. All rights reserved.

  10. Implantation of a HeartMate II left ventricular assist device via left thoracotomy.

    Science.gov (United States)

    Cho, Yang Hyun; Deo, Salil V; Schirger, John A; Pereira, Naveen L; Stulak, John M; Park, Soon J

    2012-11-01

    Left thoracotomy was used as an approach for the implantation of pulsatile ventricular assist devices. Avoiding the standard approach of median sternotomy is attractive in patients undergoing complicated redo cardiac surgery, especially with prior mediastinal radiation. We report a case of the use of left thoracotomy for the implantation of the HeartMate II axial-flow pump. Copyright © 2012 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  11. The successful implantation of continuous-flow left ventricular assist device as a destination therapy in Korea: echocardiographic assessment.

    Science.gov (United States)

    Lee, Ga Yeon; Park, Sung-Ji; Kim, Sujin; Choi, Namgyung; Jeong, Dong Seop; Jeon, Eun-Seok; Lee, Young Tak

    2014-01-01

    Left ventricular assist device (LVAD) is a good treatment option for the patients ineligible for cardiac transplantation. Several studies have demonstrated that a ventricular assist device improves the quality of life and prognosis of the patients with end-stage heart failure. A 75-yr-old man debilitated with New York Heart Association (NYHA) functional class III-IV due to severe left ventricular systolic dysfunction received LVAD implantation as a destination therapy. The patient was discharged with improved functional status (NYHA functional class II) after appropriate cardiac rehabilitation and education about how to manage the device and potential emergency situations. This is the first case of successful continuous-flow LVAD implantation as a destination therapy in Korea.

  12. Right ventricular perforation by a passive-fixation pacemaker lead two weeks after implantation

    Directory of Open Access Journals (Sweden)

    Azeem S. Sheikh, BSc, MBBS, FCPS, MRCP

    2014-12-01

    Full Text Available Myocardial perforation is a rare complication of permanent pacemaker implantation. While most of the perforations occur at the time of implantation or within the first 24 h, delayed myocardial perforations are very rare. The clinical course is extremely variable with some patients presenting completely asymptomatic, while others can develop cardiac tamponade and haemodynamic instability. We report an unusual case of a subacute ventricular perforation caused by a passive-fixation lead two weeks after implantation and we successfully managed to extract the lead under local anaesthesia, without the patient undergoing surgery, as recommended in the previously published reports.

  13. Beneficial aspects of real time flow measurements for the management of acute right ventricular heart failure following continuous flow ventricular assist device implantation

    Directory of Open Access Journals (Sweden)

    Spiliopoulos Sotirios

    2012-11-01

    Full Text Available Abstract Background Optimal management of acute right heart failure following the implantation of a left ventricular assist device requires a reliable estimation of left ventricular preload and contractility. This is possible by real-time pump blood flow measurements. Clinical case We performed implantation of a continuous flow left ventricular assist device in a 66 years old female patient with an end-stage heart failure on the grounds of a dilated cardiomyopathy. Real-time pump blood flow was directly measured by an ultrasonic flow probe placed around the outflow graft. Diagnosis The progressive decline of real time flow and the loss of pulsatility were associated with an increase of central venous pressure, inotropic therapy and progressive renal failure suggesting the presence of an acute right heart failure. Diagnosis was validated by echocardiography and thermodilution measurements. Treatment Temporary mechanical circulatory support of the right ventricle was successfully performed. Real time flow measurement proved to be a useful tool for the diagnosis and ultimately for the management of right heart failure including the weaning from extracorporeal membrane oxygenation.

  14. Outcomes of patients with right ventricular failure on milrinone after left ventricular assist device implantation.

    Science.gov (United States)

    Tsiouris, Athanasios; Paone, Gaetano; Brewer, Robert J; Nemeh, Hassan W; Borgi, Jamil; Morgan, Jeffrey A

    2015-01-01

    Previous studies have grouped together both patients requiring right ventricular assist devices (RVADs) with patients requiring prolonged milrinone therapy after left ventricular assist device (LVAD) implantation. We retrospectively identified 149 patients receiving LVADs and 18 (12.1%) of which developed right ventricular (RV) failure. We then separated these patients into those requiring RVADs versus prolonged milrinone therapy. This included 10 patients who were treated with prolonged milrinone and eight patients who underwent RVAD placement. Overall, the RV failure group had worse survival compared with the non-RV failure cohort (p = 0.038). However, this was only for the subgroup of patients who required RVADs, who had a 1, 6, 12, and 24 month survival of 62.5%, 37.5%, 37.5%, and 37.5%, respectively, versus 96.8%, 92.1%, 86.7%, and 84.4% for patients without RV failure (p milrinone therapy for RV failure had similar survivals compared with patients without RV failure. In the RV failure group, age, preoperative renal failure, and previous cardiac surgery were predictors of the need for prolonged postoperative milrinone. As LVADs become a more widely used therapy for patients with refractory, end-stage heart failure, it will be important to reduce the incidence of RV failure, as it yields significant morbidity and increases cost.

  15. Implantable Cardioverter-Defibrillator Therapy in Arrhythmogenic Right Ventricular Dysplasia/Cardiomyopathy: Predictors of Appropriate Therapy, Outcomes, and Complications.

    Science.gov (United States)

    Orgeron, Gabriela M; James, Cynthia A; Te Riele, Anneline; Tichnell, Crystal; Murray, Brittney; Bhonsale, Aditya; Kamel, Ihab R; Zimmerman, Stephan L; Judge, Daniel P; Crosson, Jane; Tandri, Harikrishna; Calkins, Hugh

    2017-06-06

    Arrhythmogenic right ventricular dysplasia/cardiomyopathy is characterized by ventricular arrhythmias and sudden cardiac death. Once the diagnosis is established, risk stratification to determine whether implantable cardioverter-defibrillator (ICD) placement is warranted is critical. The cohort included 312 patients (163 men, age at presentation 33.6±13.9 years) with definite arrhythmogenic right ventricular dysplasia/cardiomyopathy who received an ICD. Over 8.8±7.33 years, 186 participants (60%) had appropriate ICD therapy and 58 (19%) had an intervention for ventricular fibrillation/flutter. Ventricular tachycardia at presentation (hazard ratio [HR]: 1.86; 95% confidence interval [CI], 1.38-2.49; P right ventricular dysplasia/cardiomyopathy. © 2017 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.

  16. Intraoperative Hemodynamic and Echocardiographic Measurements Associated With Severe Right Ventricular Failure After Left Ventricular Assist Device Implantation.

    Science.gov (United States)

    Gudejko, Michael D; Gebhardt, Brian R; Zahedi, Farhad; Jain, Ankit; Breeze, Janis L; Lawrence, Matthew R; Shernan, Stanton K; Kapur, Navin K; Kiernan, Michael S; Couper, Greg; Cobey, Frederick C

    2018-06-05

    Severe right ventricular failure (RVF) after left ventricular assist device (LVAD) implantation increases morbidity and mortality. We investigated the association between intraoperative right heart hemodynamic data, echocardiographic parameters, and severe versus nonsevere RVF. A review of LVAD patients between March 2013 and March 2016 was performed. Severe RVF was defined by the need for a right ventricular mechanical support device, inotropic, and/or inhaled pulmonary vasodilator requirements for >14 days. From a chart review, the right ventricular failure risk score was calculated and right heart hemodynamic data were collected. Pulmonary artery pulsatility index (PAPi) [(pulmonary artery systolic pressure - pulmonary artery diastolic pressure)/central venous pressure (CVP)] was calculated for 2 periods: (1) 30 minutes before cardiopulmonary bypass (CPB) and (2) after chest closure. Echocardiographic data were recorded pre-CPB and post-CPB by a blinded reviewer. Univariate logistic regression models were used to examine the performance of hemodynamic and echocardiographic metrics. A total of 110 LVAD patients were identified. Twenty-five did not meet criteria for RVF. Of the remaining 85 patients, 28 (33%) met criteria for severe RVF. Hemodynamic factors associated with severe RVF included: higher CVP values after chest closure (18 ± 9 vs 13 ± 5 mm Hg; P = .0008) in addition to lower PAPi pre-CPB (1.2 ± 0.6 vs 1.7 ± 1.0; P = .04) and after chest closure (0.9 ± 0.5 vs 1.5 ± 0.8; P = .0008). Post-CPB echocardiographic findings associated with severe RVF included: larger right atrial diameter major axis (5.4 ± 0.9 vs 4.9 ± 1.0 cm; P = .03), larger right ventricle end-systolic area (22.6 ± 8.4 vs 18.5 ± 7.9 cm; P = .03), lower fractional area of change (20.2 ± 10.8 vs 25.9 ± 12.6; P = .04), and lower tricuspid annular plane systolic excursion (0.9 ± 0.2 vs 1.1 ± 0.3 cm; P = .008). Right ventricular failure risk score was not a significant predictor of

  17. Recent progress in the development of Terumo implantable left ventricular assist system.

    Science.gov (United States)

    Nojiri, C; Kijima, T; Maekawa, J; Horiuchi, K; Kido, T; Sugiyama, T; Mori, T; Sugiura, N; Asada, T; Shimane, H; Ozaki, T; Suzuki, M; Akamatsu, T; Akutsu, T

    1999-01-01

    The research group of the Terumo Corporation, the NTN Corporation, and Setsunan University (T. Akamatsu) has been developing an implantable left ventricular assist system (ILVAS) featuring a centrifugal blood pump with a magnetically suspended impeller (MSCP). The impeller of the MSCP is suspended by a magnetic bearing, providing contact-free rotation of the impeller inside the pump housing. Thus the MSCP is expected to provide years of long-term durability. Ex vivo chronic sheep experiments using the extracorporeal model (Model I) demonstrated long-term durability, nonthrombogenicity, and a low hemolysis rate (plasma free Hb model (Model II; 196 ml, 400 g) was evaluated ex vivo in 2 sheep and intrathoracically implanted in a small sheep (45 kg). These experiments were terminated at 70, 79, and 17 days, respectively, because of blood leakage through the connector system within the housing of Model II. There was no thrombus formation on the retrieved pump surfaces. A new connector system was introduced to the Model II pump (modified Model II), and the pump was intrathoracically implanted in a sheep. Pump flow rate was maintained at 3-7 L/min at 1700-1800 rpm. The temperature elevation on the surfaces of the motor and the electromagnet inside the pump casing was kept less than 6 degrees C. The temperature of the tissue adjacent to the pump casing became normal 10 days postoperatively. The sheep survived for more than 5 months without any sign of mechanical failure or thromboembolic complication. In vitro real-time endurance tests of motor bearings made of stainless steel and silicone nitride have been conducted for more than 1 year without any sign of bearing wear. The next prototype system (Model III), with an implantable controller and a new MSCP with reduced input power, has been developed with a view toward a totally implantable LVAS.

  18. Preoperative atrial fibrillation increases risk of thromboembolic events after left ventricular assist device implantation.

    Science.gov (United States)

    Stulak, John M; Deo, Salil; Schirger, John; Aaronson, Keith D; Park, Soon J; Joyce, Lyle D; Daly, Richard C; Pagani, Francis D

    2013-12-01

    Because no series has specifically analyzed the impact of preoperative atrial fibrillation (AF) on patients already at higher risk of thromboembolism after implantation of a left ventricular assist device (LVAD), we review our experience with these patients. Between July 2003 and September 2011, 389 patients (308 male) underwent implantation of a continuous flow LVAD at University of Michigan Hospital and Mayo Clinic. Median age at implant was 60 years (range, 18 to 79 years). Preoperative AF was present in 120 patients (31%). Outcomes were analyzed for the association of preoperative AF and postoperative thromboembolic (TE) events defined as stroke, transient ischemic attack, hemolysis, or pump thrombosis. Thromboembolic events occurring within the first 30 days were not counted. One hundred thirty-eight TEs events occurred in 97/389 patients (25%) for an event rate of 0.31 TE events/patient-years of support. Freedom from a TE event in patients with preoperative AF was 62% at 1 year and 46% at 2 years compared with 79% and 72% at 1 and 2 years, respectively, in patients without preoperative AF (p < 0.001). Median survival was 10 months (maximum 7.2 years, total 439 patient-years). Preoperative AF did not decrease late survival at 1 and 2 years after LVAD implant (preop AF: 85% and 70% versus no preop AF: 82% and 70%, respectively; p = 0.55). Patients with preoperative AF have a lower freedom from TE events after LVAD implant. While overall late survival was not significantly reduced in these patients, refinement in anticoagulation strategies after VAD implant may be required. Copyright © 2013 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  19. Predictors of ventricular tachyarrhythmia occurring late after intracardiac repair of tetralogy of Fallot: combination of QRS duration change rate and tricuspid regurgitation pressure gradient

    Science.gov (United States)

    Takahashi, Masashi; Sugimoto, Ai; Tsuchida, Masanori

    2017-01-01

    Background To determine potential predictors of ventricular tachyarrhythmia and sudden cardiac death (SCD) occurring late after repair of tetralogy of Fallot (TOF). Methods Since 1964, 415 patients had undergone total repair for TOF at Niigata University Hospital. Of these, 89 patients who were followed for more than 10 years at our institute were retrospectively reviewed. Results The mean follow-up period was 24.3 years. During the study period, one patient died of cerebral bleeding, and two patients had SCD. The overall survival rates at 20, 30, and 40 years were 100%, 94.6%, and 94.6%, respectively. Eight (9.0%) patients required re-intervention during the late period associated with right ventricular outflow (n=4), tricuspid valve (n=3), aortic valve (n=2), and others (n=2). Ten (11.2%) patients had a history of ventricular tachycardia (VT) or ventricular fibrillation (VF), and six underwent implantation of an implantable cardiac defibrillator. Multivariate analysis selected the change rate of QRS duration [ms/year; odds ratio (OR), 2.44; 95% confidence interval (CI): 1.28–4.65; P=0.007] and the pressure gradient at tricuspid valve regurgitation on echocardiography (OR, 1.12; 95% CI: 1.02–1.22; P=0.017) as risk factors for VT/VF or SCD. Trans-annular patch (TAP) repair was not an independent risk factor for ventricular arrhythmia. Conclusions The combination of rapid change rate of QRS duration and higher-pressure gradient at tricuspid regurgitation were risk factors for ventricular tachyarrhythmia late after TOF repair. Adequate surgical or catheter intervention for pressure and volume load in the right ventricle might decrease the prevalence of VT/VF and SCD. PMID:29312717

  20. Multigated radionuclide study of the total artificial heart

    International Nuclear Information System (INIS)

    Datz, F.L.; Christian, P.E.; Taylor, A. Jr.; Hastings, W.L.; De Vries, W.C.

    1987-01-01

    A permanent total artificial heart, the Jarvik-7, was implanted into a 61-year-old male with a severe cardiomyopathy. Gated radionuclide studies were performed in the patient both prior to surgery and following implantation. Preoperative gated radionuclide cardiac studies revealed marked left ventricular enlargement, severe hypokinesis and a left ventricular ejection fraction of 10%. The right ventricle was moderately enlarged with a 27% ejection fraction. Following implantation of the Jarvik-7 artificial heart, gated cardiac studies were performed with a computer gated by a signal from the heart controller. The left ventricular ejection fraction was 69% and the right ventricular ejection fraction was 62%. This compared to a theoretical ejection fraction of 74% for each ventricle based on chamber anatomy. There was excellent ventricular emptying. Phase analysis showed uniform diaphragm motion. The use of gated cardiac studies in humans may prove helpful in evaluating mechanical problems with the artificial heart, such as manlfunction of the diaphragm, before they become clinically apparent. (orig.)

  1. Multigated radionuclide study of the total artificial heart

    Energy Technology Data Exchange (ETDEWEB)

    Datz, F L; Christian, P E; Taylor, A Jr; Hastings, W L; De Vries, W C

    1987-07-01

    A permanent total artificial heart, the Jarvik-7, was implanted into a 61-year-old male with a severe cardiomyopathy. Gated radionuclide studies were performed in the patient both prior to surgery and following implantation. Preoperative gated radionuclide cardiac studies revealed marked left ventricular enlargement, severe hypokinesis and a left ventricular ejection fraction of 10%. The right ventricle was moderately enlarged with a 27% ejection fraction. Following implantation of the Jarvik-7 artificial heart, gated cardiac studies were performed with a computer gated by a signal from the heart controller. The left ventricular ejection fraction was 69% and the right ventricular ejection fraction was 62%. This compared to a theoretical ejection fraction of 74% for each ventricle based on chamber anatomy. There was excellent ventricular emptying. Phase analysis showed uniform diaphragm motion. The use of gated cardiac studies in humans may prove helpful in evaluating mechanical problems with the artificial heart, such as manlfunction of the diaphragm, before they become clinically apparent.

  2. Ventricular assist device implantation in a young patient with non-compaction cardiomyopathy and hereditary spherocytosis.

    Science.gov (United States)

    Huenges, Katharina; Panholzer, Bernd; Cremer, Jochen; Haneya, Assad

    2018-04-01

    A case of a 15-year-old female patient with acute heart failure due to non-compaction cardiomyopathy and hereditary anaemia (hereditary spherocytic elliptocytosis) requiring ventricular assist device implantation as a bridge to transplantation is presented. The possible effects of mechanical stress on erythrocytes potentially induced by mechanical circulatory support remains unclear, but it may lead to haemolytic crisis in patients suffering from hereditary anaemia. In our case, ventricular assist device therapy was feasible, and haematological complications did not occur within 6 weeks of bridging our patient to heart transplantation.

  3. Outcomes of ventricular assist device implantation in children and young adults: the Melbourne experience.

    Science.gov (United States)

    Shi, William Y; Marasco, Silvana F; Saxena, Pankaj; d'Udekem, Yves; Yong, Matthew S; Mitnovetski, Sergei; Brizard, Christian P; McGiffin, David C; Weintraub, Robert G; Konstantinov, Igor E

    2016-12-01

    We evaluated our experience with ventricular assist device (VAD) implantation in children and young adults. A total of 64 patients underwent VAD implantation in two centres. The mean age was 15 ± 7.2 years. Thirty-five (55%) patients were under 18 years of age. Devices implanted included the Thoratec Paracorporeal in 30 (47%) patients, Berlin Heart EXCOR in 11 (17%) and VentrAssist in 14 (22%). The diagnosis was cardiomyopathy in 53, congenital heart disease in 11, and graft failure in four patients. There were 10 (16%) in-hospital deaths. Mortality was higher in patients <18 years of age (26% compared with 3.4% for those ≥18 years, P = 0.02). The use of extracorporeal membrane oxygenation prior to VAD implantation was associated with higher mortality (P = 0.006). Seventeen (27%) patients experienced stroke. Nine patients (14%) required change of VAD because of thrombosis. Transplantation was performed in 44 patients after a mean of 131 ± 141 days on VAD, 11 patients died without transplantation and three patients currently await transplantation. The VAD was explanted in six patients because of recovery. Overall survival from VAD implantation was 69% and 61% at 5 and 10 years, respectively. The 5-year post-transplant survival for those bridged with VAD support was 91% and was comparable with a cohort of patients who did not receive a pre-transplant VAD. Children requiring pre-transplant VAD support have a higher mortality and morbidity compared with young adults. Survival after heart transplantation those supported with VADs was similar to patients of similar age who did not require pre-transplant support. © 2015 Royal Australasian College of Surgeons.

  4. Left Ventricular Assist Device Implantation with Concomitant Aortic Valve and Ascending Aortic Replacement.

    Science.gov (United States)

    Huenges, Katharina; Panholzer, Bernd; Cremer, Jochen; Haneya, Assad

    2018-01-01

    Left ventricular assist device (LVAD) is nowadays a routine therapy for patients with advanced heart failure. We present the case of a 74-year-old male patient who was admitted to our center with terminal heart failure in dilated cardiomyopathy and ascending aortic aneurysm with aortic valve regurgitation. The LVAD implantation with simultaneous aortic valve and supracoronary ascending aortic replacement was successfully performed.

  5. Optimal Timing of Heart Transplant After HeartMate II Left Ventricular Assist Device Implantation.

    Science.gov (United States)

    Steffen, Robert J; Blackstone, Eugene H; Smedira, Nicholas G; Soltesz, Edward G; Hoercher, Katherine J; Thuita, Lucy; Starling, Randall C; Mountis, Maria; Moazami, Nader

    2017-11-01

    Optimal timing of heart transplantation in patients supported with second-generation left ventricular assist devices (LVADs) is unknown. Despite this, patients with LVADs continue to receive priority on the heart transplant waiting list. Our objective was to determine the optimal timing of transplantation for patients bridged with continuous-flow LVADs. A total of 301 HeartMate II LVADs (Thoratec Corp, Pleasanton, CA) were implanted in 285 patients from October 2004 to June 2013, and 86 patients underwent transplantation through the end of follow-up. Optimal transplantation timing was the product of surviving on LVAD support and surviving transplant. Three-year survival after both HeartMate II implantation and heart transplantation was unchanged when transplantation occurred within 9 months of implantation. Survival decreased as the duration of support exceeded this. Preoperative risk factors for death on HeartMate II support were prior valve operation, prior coronary artery bypass grafting, low albumin, low glomerular filtration rate, higher mean arterial pressure, hypertension, and earlier date of implant. Survival for patients without these risk factors was lowest when transplant was performed within 3 months but was relatively constant with increased duration of support. Longer duration of support was associated with poorer survival for patients with many of these risk factors. Device reimplantation, intracranial hemorrhage, and postimplant dialysis during HeartMate II support were associated with decreased survival. Survival of patients supported by the HeartMate II is affected by preoperative comorbidities and postoperative complications. Transplantation before complications is imperative in optimizing survival. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  6. Transcatheter aortic valve implantation: emerging role in poor left ventricular function severe aortic stenosis?

    Directory of Open Access Journals (Sweden)

    K. M. John Chan

    2014-01-01

    Full Text Available Transcatheter aortic valve implantation (TAVI has become an established treatment option for high risk elderly patients with symptomatic severe aortic stenosis. Its role in less high risk patients is being evaluated in clinical trials. Patients with severely impaired left ventricular function may be another group who may benefit from this emerging percutaneous treatment option.

  7. Percutaneous pulmonary valve implantation in patients with dysfunction of a "native" right ventricular outflow tract - Mid-term results.

    Science.gov (United States)

    Georgiev, Stanimir; Tanase, Daniel; Ewert, Peter; Meierhofer, Christian; Hager, Alfred; von Ohain, Jelena Pabst; Eicken, Andreas

    2018-05-01

    To investigate the feasibility and mid-term results of percutaneous pulmonary valve implantation (PPVI) in patients with conduit free or "native" right ventricular outflow tracts (RVOT). We identified all 18 patients with conduit free or "native" right ventricular outflow tract, who were treated with percutaneous pulmonary valve implantation (PPVI) in our institution. They were divided into two groups - these in whom the central pulmonary artery was used as an anchoring point for the preparation of the landing zone (n=10) for PPVI and these, in whom a pulmonary artery branch was used for this purpose (n=8). PPVI was performed successfully in all patients with significant immediate RVOT gradient and pulmonary regurgitation grade reduction. Four patients had insignificant paravalvular regurgitation. In one patient the valve was explanted after 4months because of bacterial endocarditis. A follow-up of 19 (4-60) months showed sustained good function of the other implanted valves. The MRI indexed right ventricular end diastolic volume significantly decreased from 108(54-174) ml/m 2 before the procedure to 76(60-126) ml/m 2 six months after PPVI, p=0.01. PPVI is feasible with good mid-term results in selected patients with a "native" RVOT without a previously implanted conduit. Creating a stable landing zone with a diameter less than the largest available valve (currently 29mm) is crucial for the technical success of the procedure. Further studies and the development of new devices could widen the indications for this novel treatment. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Can using a peel-away sheath in shunt implantation prevent ventricular catheter obstruction?

    Science.gov (United States)

    Camlar, Mahmut; Ersahin, Yusuf; Ozer, Fusun Demirçivi; Sen, Fatih; Orman, Mehmet

    2011-02-01

    Shunt obstruction is the most common shunt complication. In 2003, Kehler et al. used peel-away sheath while implanting the ventricular catheter in 20 patients. They found less revision rate in the peel-away sheath group. We aimed to test the efficacy of this technique in cadavers. We used 100 fresh brains obtained from medicolegal autopsies. Posterior parietal and frontal approaches were used to puncture the lateral ventricle in each cerebral hemisphere. The ventricle is punctured with a peel-away sheath system. After the ventricle is reached, the mandarin is retracted and the ventricular catheter is introduced through the opening. The ventricular catheter was removed from the ventricle, the opening at the tip of the ventricular catheter was checked out for obstruction, and the number of patent and plugged openings was recorded. This procedure was repeated four times for each location with and without using peel-away sheath. The control group consisted of the procedures done without using peel-away sheath. The number of the plugged openings in the peel-away sheath group was significantly smaller than the control group. There was no significant difference between the two groups in terms of gender and left and right cerebral hemispheres. The obstruction rate was significantly lower in the posterior parietal approach. Pearson's correlation showed that increasing age was associated with less obstruction rate. Peel-away sheath decreases the number of plugged openings of the ventricular catheter. A clinical cooperative study is needed to prove that a peel-away sheath should be included in the ventricular shunt systems in the market.

  9. Reduced Anxiety and Depression in Patients With Advanced Heart Failure After Left Ventricular Assist Device Implantation.

    Science.gov (United States)

    Yost, Gardner; Bhat, Geetha; Mahoney, Edward; Tatooles, Antone

    Despite the high prevalence of depression and anxiety in patients with advanced heart failure, the effects of left ventricular assist device (LVAD) implantation on these critically important aspects of mental health are not well understood. We sought to assess changes in depression and anxiety following LVAD implantation. The Beck Depression Inventory-II (BDI-II) and Beck Anxiety Inventory (BAI) were administered to 54 patients by a clinical psychologist at a mean of 12 days before LVAD implantation and 251 days after implantation. Patient demographics and clinical data were collected concurrently to psychologic testing. Changes in BDI-II, BAI, and clinical markers of heart failure were assessed using paired t-tests. A p Psychosomatic Medicine. Published by Elsevier Inc. All rights reserved.

  10. Unmappable ventricular tachycardia after an old myocardial infarction. Long-term results of substrate modification in patients with an implantable cardioverter defibrillator

    OpenAIRE

    Alzand, B. S. N.; Timmermans, C. C. M. M.; Wellens, H. J. J.; Dennert, R.; Philippens, S. A. M.; Portegijs, P. J. M.; Rodriguez, LM.

    2011-01-01

    Purpose The frequent occurrence of ventricular tachycardia can create a serious problem in patients with an implantable cardioverter defibrillator. We assessed the long-term efficacy of catheter-based substrate modification using the voltage mapping technique of infarct-related ventricular tachycardia and recurrent device therapy. Methods The study population consisted of 27 consecutive patients (age 68 ± 8 years, 25 men, mean left ventricular ejection fraction 31 ± 9%) with an old myocardial...

  11. Implantable cardioverter-defibrillators improve survival after coronary artery bypass grafting in patients with severely impaired left ventricular function

    Directory of Open Access Journals (Sweden)

    Pasque Michael K

    2007-01-01

    Full Text Available Abstract Objective Patients with severe left ventricular (LV dysfunction have a poor long term survival despite complete surgical revascularization. Recent data suggests that the use of Implantable Cardioverter-Defibrillator (ICD improves survival in patients with severe LV dysfunction. We compared the survival impact of ICD implantation in patients with severe LV dysfunction who underwent CABG. Methods Between January 1996 and August 2004, 305 patients with LV ejection fraction (EF ≤25% had CABG surgery at our institution. Demographics of patients who had received an ICD (ICD+ in the post -operative period was compared to those without ICD (ICD-. Survival was evaluated by the Kaplan-Meier method. Results Of the entire group, 35 (11.5% patients received an ICD with a median of 2 (+/-2 years after CABG. Indication for ICD implantation was clinical evidence of non sustained ventricular tachycardia (NSVT. There were no differences between the 2 groups with respect to age, gender, NYHA classification, number of bypasses, or other co-morbidities. Survival at 1, 3 and 5 years was 88%, 79%, and 67% for the ICD- group compared to 94%, 89% and 83% for the ICD+ group, respectively (figure, p Conclusion Implantation of ICD after CABG confers improved short and long term survival benefit to patients with severe LV dysfunction. Prophylactic ICD implantation in the setting of severe LV dysfunction and CABG surgery should be considered.

  12. Importance of the atrial channel for ventricular arrhythmia therapy in the dual chamber implantable cardioverter defibrillator.

    Science.gov (United States)

    Dijkman, B; Wellens, H J

    2000-12-01

    Performance of dual chamber implantable cardioverter defibrillator (ICD) systems has been judged based on functioning of the ventricular tachycardia:supraventricular tachycardia (VT:SVT) discrimination criteria and DDD pacing. The purpose of this study was to evaluate the use of dual chamber diagnostics to improve the electrical and antiarrhythmic therapy of ventricular arrhythmias. Information about atrial and ventricular rhythm in relation to ventricular arrhythmia occurrence and therapy was evaluated in 724 spontaneous arrhythmia episodes detected and treated by three types of dual chamber ICDs in 41 patients with structural heart disease. Device programming was based on clinically documented and induced ventricular arrhythmias. In ambulatory patients, sinus tachycardia preceded ventricular arrhythmias more often than in the hospital during exercise testing. The incidence of these VTs could be reduced by increasing the dose of a beta-blocking agent in only two patients. In five patients in whom sinus tachycardia developed after onset of hemodynamic stable VT, propranolol was more effective than Class III antiarrhythmics combined with another beta-blocking agent with regard to the incidence of VT and pace termination. In all but three cases, atrial arrhythmias were present for a longer time before the onset of ventricular arrhythmias. During atrial arrhythmias, fast ventricular rates before the onset of ventricular rate were observed more often than RR irregularities and short-long RR sequences. Dual chamber diagnostics allowed proper interpretation of detection and therapy outcome in patients with different types of ventricular arrhythmia. The advantages of the dual chamber ICD system go further than avoiding the shortcomings of the single chamber system. Information from the atrial chamber allows better device programming and individualization of drug therapy for ventricular arrhythmia.

  13. Ventricular fibrillation in an ambulatory patient supported by a left ventricular assist device: highlighting the ICD controversy.

    Science.gov (United States)

    Boilson, Barry A; Durham, Lucian A; Park, Soon J

    2012-01-01

    Left ventricular assist devices (LVADs) provide an effective means of managing advanced pump failure as a means of bridging to cardiac transplantation or as permanent therapy. Although ventricular arrhythmias remain common post-LVAD implantation, such therapy may allow malignant arrhythmias to be tolerated hemodynamically. This report describes the clinical findings in a patient who had likely been in a ventricular tachyarrhythmia for several days and presented in ventricular fibrillation, ambulatory, and mentating normally. This report, with previous similar reports, is additive to the body of evidence that LVADs alter the physiologic impact of ventricular arrhythmias in advanced heart failure and highlights the need for thoughtful programming of implantable cardioverter defibrillator therapies in these patients.

  14. Totally implantable total artificial heart and ventricular assist device with multipurpose miniature electromechanical energy system.

    Science.gov (United States)

    Takatani, S; Orime, Y; Tasai, K; Ohara, Y; Naito, K; Mizuguchi, K; Makinouchi, K; Damm, G; Glueck, J; Ling, J

    1994-01-01

    A multipurpose miniature electromechanical energy system has been developed to yield a compact, efficient, durable, and biocompatible total artificial heart (TAH) and ventricular assist device (VAD). Associated controller-driver electronics were recently miniaturized and converted into hybrid circuits. The hybrid controller consists of a microprocessor and controller, motor driver, Hall sensor, and commutation circuit hybrids. The sizing study demonstrated that all these components can be incorporated in the pumping unit of the TAH and VAD, particularly in the centerpiece of the TAH and the motor housing of the VAD. Both TAH and VAD pumping units will start when their power line is connected to either the internal power pack or the external battery unit. As a redundant driving and diagnostic port, an emergency port was newly added and will be placed in subcutaneous location. In case of system failure, the skin will be cut down, and an external motor drive or a pneumatic driver will be connected to this port to run the TAH. This will minimize the circulatory arrest time. Overall efficiency of the TAH without the transcutaneous energy transmission system was 14-18% to deliver pump outputs of 4-9 L/min against the right and left afterload pressures of 25 and 100 mm Hg. The internal power requirement ranged from 6 to 13 W. The rechargeable batteries such as NiCd or NiMH with 1 AH capacity can run the TAH for 30-45 min. The external power requirement, when TETS efficiency of 75% was assumed, ranged from 8 to 18 W. The accelerated endurance test in the 42 degrees C saline bath demonstrated stable performance over 4 months. Long-term endurance and chronic animal studies will continue toward a system with 5 years durability by the year 2000.

  15. "Pseudo" Faraday cage: a solution for telemetry link interaction between a left ventricular assist device and an implantable cardioverter defibrillator.

    Science.gov (United States)

    Jacob, Sony; Cherian, Prasad K; Ghumman, Waqas S; Das, Mithilesh K

    2010-09-01

    Patients implanted with left ventricular assist devices (LVAD) may have implantable cardioverter defibrillators (ICD) implanted for sudden cardiac death prevention. This opens the possibility of device-device communication interactions and thus interferences. We present a case of such interaction that led to ICD communication failure following the activation of an LVAD. In this paper, we describe a practical solution to circumvent the communication interference and review the communication links of ICDs and possible mechanisms of ICD-LVAD interactions.

  16. Performance of the 2015 International Task Force Consensus Statement Risk Stratification Algorithm for Implantable Cardioverter-Defibrillator Placement in Arrhythmogenic Right Ventricular Dysplasia/Cardiomyopathy.

    Science.gov (United States)

    Orgeron, Gabriela M; Te Riele, Anneline; Tichnell, Crystal; Wang, Weijia; Murray, Brittney; Bhonsale, Aditya; Judge, Daniel P; Kamel, Ihab R; Zimmerman, Stephan L; Tandri, Harikrishna; Calkins, Hugh; James, Cynthia A

    2018-02-01

    Ventricular arrhythmias are a feared complication of arrhythmogenic right ventricular dysplasia/cardiomyopathy. In 2015, an International Task Force Consensus Statement proposed a risk stratification algorithm for implantable cardioverter-defibrillator placement in arrhythmogenic right ventricular dysplasia/cardiomyopathy. To evaluate performance of the algorithm, 365 arrhythmogenic right ventricular dysplasia/cardiomyopathy patients were classified as having a Class I, IIa, IIb, or III indication per the algorithm at baseline. Survival free from sustained ventricular arrhythmia (VT/VF) in follow-up was the primary outcome. Incidence of ventricular fibrillation/flutter cycle length the algorithm appropriately differentiated risk of VT/VF, incidence of VT/VF was underestimated (observed versus expected: 29.6 [95% confidence interval, 25.2-34.0] versus >10%/year Class I; 15.5 [confidence interval 11.1-21.6] versus 1% to 10%/year Class IIa). In addition, the algorithm did not differentiate survival free from ventricular fibrillation/flutter between Class I and IIa patients ( P =0.97) or for VT/VF in Class I and IIa primary prevention patients ( P =0.22). Adding Holter results (the algorithm differentiates arrhythmic risk well overall, it did not distinguish ventricular fibrillation/flutter risks of patients with Class I and IIa implantable cardioverter-defibrillator indications. Limited differentiation was seen for primary prevention cases. As these are vital uncertainties in clinical decision-making, refinements to the algorithm are suggested prior to implementation. © 2018 American Heart Association, Inc.

  17. Expanding TAVI options: elective rotational atherectomy during trans-catheter aortic valve implantation

    International Nuclear Information System (INIS)

    Piccoli, Anna; Lunardi, Mattia; Ariotti, Sara; Ferrero, Valeria; Vassanelli, Corrado; Ribichini, Flavio

    2015-01-01

    Summary: Aortic valve stenosis (AVS) in the elderly is frequently associated to coronary artery disease (CAD). In patients with significant coronary stenosis surgical valve replacement is associated to coronary bypass grafting, but whether coronary angioplasty is needed in patients receiving trans-catheter aortic valve implantation (TAVI) is unknown. Given the frequent complexity of CAD in the elderly with calcific AVS, rotational atherectomy (RA) may be needed in some cases. No data are available about feasibility and safety of RA during TAVI. The need for myocardial revascularization in TAVI candidates is discussed, and a series of RA cases performed during TAVI is described

  18. Expanding TAVI options: elective rotational atherectomy during trans-catheter aortic valve implantation

    Energy Technology Data Exchange (ETDEWEB)

    Piccoli, Anna; Lunardi, Mattia; Ariotti, Sara; Ferrero, Valeria; Vassanelli, Corrado; Ribichini, Flavio, E-mail: flavio.ribichini@univr.it

    2015-01-15

    Summary: Aortic valve stenosis (AVS) in the elderly is frequently associated to coronary artery disease (CAD). In patients with significant coronary stenosis surgical valve replacement is associated to coronary bypass grafting, but whether coronary angioplasty is needed in patients receiving trans-catheter aortic valve implantation (TAVI) is unknown. Given the frequent complexity of CAD in the elderly with calcific AVS, rotational atherectomy (RA) may be needed in some cases. No data are available about feasibility and safety of RA during TAVI. The need for myocardial revascularization in TAVI candidates is discussed, and a series of RA cases performed during TAVI is described.

  19. Malignant ventricular tachycardia in acromegaly: a case report

    Directory of Open Access Journals (Sweden)

    Zhe An

    Full Text Available CONTEXT: In patients with acromegaly, cardiovascular complications are the main cause of death; sudden death has been associated with ventricular tachyarrhythmias. In other patients with life-threatening malignant ventricular tachyarrhythmias, surgical placement of an implantable cardioverter-defibrillator (ICD has proved highly effective in reducing sudden death rates. CASE REPORT: The present article reports the case of a 50-year-old male acromegalic patient who presented symptoms of syncope induced by ventricular tachycardia. An ICD was surgically implanted and a pituitary adenoma, which was responsible for the acromegaly, was completely removed in the same procedure. The surgery was successful and the ventricular arrhythmias were effectively terminated. During six months of follow-up, no documented arrhythmic episodes occurred. CONCLUSION: In patients with acromegaly, malignant ventricular tachyarrhythmia might be effectively controlled by implantation of an ICD and surgical removal of the pituitary adenoma.

  20. Prognostic significance of nonsustained ventricular tachycardia after revascularization.

    Science.gov (United States)

    Mittal, Suneet; Lomnitz, David J; Mirchandani, Sunil; Stein, Kenneth M; Markowitz, Steven M; Slotwiner, David J; Iwai, Sei; Das, Mithilesh K; Lerman, Bruce B

    2002-04-01

    Two randomized trials (Multicenter Automatic Defibrillator Implantation Trial [MADIT] and Multicenter Unsustained Tachycardia Trial [MUSTT]) suggest that implantable cardioverter defibrillator (ICD) placement is associated with improved survival in patients with coronary artery disease, depressed left ventricular function, and nonsustained ventricular tachycardia (VT) who also have inducible sustained VT. However, neither study directly addresses the management of such patients who develop nonsustained VT early after revascularization. We evaluated 109 consecutive patients who underwent electrophysiologic testing to evaluate nonsustained VT, which occurred 5 +/- 4 days following revascularization. Sustained monomorphic VT was inducible in 46 (42%) patients; these patients received an ICD. The remaining 63 (58%) noninducible patients received neither antiarrhythmic drug therapy nor an ICD. During 27 +/- 12 months of follow-up, 15 (33%) of 45 patients with an implanted ICD received at least one appropriate therapy from the device and 26 (24%) of the 109 study patients died. The 1- and 2-year freedom from ventricular tachycardia/fibrillation or sudden death in noninducible patients (97% and 93%) was significantly greater than that of inducible patients (84% and 71%; P = 0.001). However, no difference was observed in total mortality. Patients with nonsustained VT during the early postrevascularization period who have inducible VT have a high incidence of arrhythmic events. Although this study was not designed to assess the impact of ICD placement on the total mortality of inducible patients, the finding that one third of these patients received appropriate ICD therapy suggests that the device may have a protective effect in these patients.

  1. Durability of central aortic valve closure in patients with continuous flow left ventricular assist devices.

    Science.gov (United States)

    McKellar, Stephen H; Deo, Salil; Daly, Richard C; Durham, Lucian A; Joyce, Lyle D; Stulak, John M; Park, Soon J

    2014-01-01

    A competent aortic valve is essential to providing effective left ventricular assist device support. We have adopted a practice of central aortic valve closure by placing a simple coaptation stitch at left ventricular assist device implantation in patients with significant aortic insufficiency. We conducted a follow-up study to evaluate the efficacy and durability of this procedure. The study included patients who had undergone continuous flow left ventricular assist device implantation. The patients were divided into 2 groups, those who did not require any aortic procedure because the valve was competent and those who underwent central aortic valve closure for mild or greater aortic regurgitation. The clinical endpoints were mortality, progression or recurrence of aortic insufficiency, and reoperation for aortic valve pathologic features. Aortic insufficiency was measured qualitatively from mild to severe on a scale of 0 to 5. A total of 123 patients received continuous flow left ventricular assist devices from February 2007 to August 2011. Of those, 18 (15%) underwent central aortic valve closure at left ventricular assist device implantation because of significant aortic insufficiency (1.8 ± 1.4) and 105 who did not (competent aortic valve, 0.15 ± 0.43; P assist device-supported patients, with follow-up extending into 2 years. Although aortic insufficiency progressed over time in those with minimal native valve regurgitation initially, no such progression was noted in those with central aortic valve closure. Additional investigation is needed to evaluate whether prophylactic central aortic valve closure should be performed at left ventricular assist device implantation to avoid problematic aortic regurgitation developing over time, in particular in patients undergoing left ventricular assist device implantation for life-long (destination therapy) support. Copyright © 2014 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights

  2. Successful Implantation of a Left Ventricular Assist Device in a Patient with Heparin-Induced Thrombocytopenia and Thrombosis

    Science.gov (United States)

    Garland, Cassandra; Somogyi, David

    2014-01-01

    Abstract: We report the case of a 27-year-old woman with signs of heparin-induced thrombocytopenia and thrombosis (HITT) and left heart failure presenting for urgent implantation of a left ventricular assist device (LVAD). HITT can occur in 4.2–6.1% of patients with LVADs. If the patient remains hemodynamically stable, implantation can be delayed for several months until the heparin/PF-4 antibodies decline allowing the use of heparin on cardiopulmonary bypass, However, in most cases related to cardiogenic shock, surgery cannot be delayed. We present the case of a patient who underwent implantation of a HeartMate II LVAD and discuss management strategy using bivalirudin during cardiopulmonary bypass. PMID:25208434

  3. Ventricular Tachycardia Detected by Implantable Loop Recorder in a Child with Recurrent Syncope

    Directory of Open Access Journals (Sweden)

    İsa Özyılmaz

    2014-06-01

    Full Text Available In this article, we present a 10-year-old boy who was admitted to the hospital with recurrent syncope. There was no remarkable finding in patient’s physical examination, family history, and the diagnostic 12-lead electrocardiogram (ECG, chest x-ray, ECG Holter monitoring, event recording, echocardiography, coronary computed tomography (CT angiography, Ajmaline test for the diagnosis of Brugada syndrome, brain magnetic resonance imaging, and sleep/wake electroencephalogram. We started beta-blocker therapy because the patient had exercise-induced syncope. An Implantable loop recorder (ILR was inserted to the patient. Three years later, polymorphic ventricular tachycardia called torsades de pointes was detected by the ILR during syncope occurred with exercise. The patient had been taking high-dose betablocker treatment, an implantable cardioverter defibrillator was implanted into the patient. ILR can play an important role in the diagnosis of life-threatening arrhythmia in children with unexplained syncope. (The Me­di­cal Bul­le­tin of Ha­se­ki 2014; 52: 123-5

  4. Surgeons' Perspectives on Premium Implants in Total Joint Arthroplasty.

    Science.gov (United States)

    Wasterlain, Amy S; Bello, Ricardo J; Vigdorchik, Jonathan; Schwarzkopf, Ran; Long, William J

    2017-09-01

    Declining total joint arthroplasty reimbursement and rising implant prices have led many hospitals to restrict access to newer, more expensive total joint arthroplasty implants. The authors sought to understand arthroplasty surgeons' perspectives on implants regarding innovation, product launch, costs, and cost-containment strategies including surgeon gain-sharing and patient cost-sharing. Members of the International Congress for Joint Reconstruction were surveyed regarding attitudes about implant technology and costs. Descriptive and univariate analyses were performed. A total of 126 surgeons responded from all 5 regions of the United States. Although 76.9% believed new products advance technology in orthopedics, most (66.7%) supported informing patients that new implants lack long-term clinical data and restricting new implants to a small number of investigators prior to widespread market launch. The survey revealed that 66.7% would forgo gain-sharing incentives in exchange for more freedom to choose implants. Further, 76.9% believed that patients should be allowed to pay incremental costs for "premium" implants. Surgeons who believed that premium products advance orthopedic technology were more willing to forgo gain-sharing (P=.040). Surgeons with higher surgical volume (P=.007), those who believed implant companies should be allowed to charge more for new technology (Pnew implants with patients. Many surgeons support alternative payment models permitting surgeons and patients to retain implant selection autonomy. Most respondents prioritized patient beneficence and surgeon autonomy above personal financial gain. [Orthopedics. 2017; 40(5):e825-e830.]. Copyright 2017, SLACK Incorporated.

  5. QRS Width as a Predictor of Right Ventricular Remodeling After Percutaneous Pulmonary Valve Implantation.

    Science.gov (United States)

    Paech, C; Dähnert, I; Riede, F T; Wagner, R; Kister, T; Nieschke, K; Wagner, F; Gebauer, R A

    2017-08-01

    Recent data showed a right ventricular dyssynchrony in patients with tetralogy of Fallot (TOF). Percutaneous pulmonary valve implantation (PPVI) has become an important procedure to treat a pulmonary stenosis and/or regurgitation of the right ventricular outflow tract in these patients. Despite providing good results, there is still a considerable number of nonresponders to PPVI. The authors speculated that electrical dysfunction of the right ventricle plays an underestimated role in the outcome of patients after PPVI. This study aimed to investigate the influence of right ventricular electrical dysfunction, i.e., right bundle branch block (RBBB) on the RV remodeling after PPVI. The study included consecutive patients after correction of TOF with or without RBBB, who had received a PPVI previously at the Heart Center of the University of Leipzig, Germany during the period from 2012 to 2015. 24 patients were included. Patients without RBBB, i.e., with narrow QRS complexes pre-intervention, had significantly better RV function and had smaller right ventricular volumes. Patients with pre-interventionally QRS width below 150 ms showed a post-interventional remodeling of the right ventricle with the decreasing RV volumes (p = 0.001). The parameters of LV function and volume as well as RV ejection fraction remained unaffected by RBBB. The presented data indicate that the QRS width seems to be a valuable parameter in the prediction of right ventricular remodeling after PPVI, as it represents both electrical and mechanical functions of the right ventricle and may serve as an additional parameter for optimal timing of a PPVI.

  6. Real-time adjustment of ventricular restraint therapy in heart failure.

    Science.gov (United States)

    Ghanta, Ravi K; Lee, Lawrence S; Umakanthan, Ramanan; Laurence, Rita G; Fox, John A; Bolman, Ralph Morton; Cohn, Lawrence H; Chen, Frederick Y

    2008-12-01

    Current ventricular restraint devices do not allow for either the measurement or adjustment of ventricular restraint level. Periodic adjustment of restraint level post-device implantation may improve therapeutic efficacy. We evaluated the feasibility of an adjustable quantitative ventricular restraint (QVR) technique utilizing a fluid-filled polyurethane epicardial balloon to measure and adjust restraint level post-implantation guided by physiologic parameters. QVR balloons were implanted in nine ovine with post-infarction dilated heart failure. Restraint level was defined by the maximum restraint pressure applied by the balloon to the epicardium at end-diastole. An access line connected the balloon lumen to a subcutaneous portacath to allow percutaneous access. Restraint level was adjusted while left ventricular (LV) end-diastolic volume (EDV) and cardiac output was assessed with simultaneous transthoracic echocardiography. All nine ovine successfully underwent QVR balloon implantation. Post-implantation, restraint level could be measured percutaneously in real-time and dynamically adjusted by instillation and withdrawal of fluid from the balloon lumen. Using simultaneous echocardiography, restraint level could be adjusted based on LV EDV and cardiac output. After QVR therapy for 21 days, LV EDV decreased from 133+/-15 ml to 113+/-17 ml (p<0.05). QVR permits real-time measurement and physiologic adjustment of ventricular restraint therapy after device implantation.

  7. Unmappable ventricular tachycardia after an old myocardial infarction. Long-term results of substrate modification in patients with an implantable cardioverter defibrillator.

    Science.gov (United States)

    Alzand, B S N; Timmermans, C C M M; Wellens, H J J; Dennert, R; Philippens, S A M; Portegijs, P J M; Rodriguez, L M

    2011-08-01

    The frequent occurrence of ventricular tachycardia can create a serious problem in patients with an implantable cardioverter defibrillator. We assessed the long-term efficacy of catheter-based substrate modification using the voltage mapping technique of infarct-related ventricular tachycardia and recurrent device therapy. The study population consisted of 27 consecutive patients (age 68 ± 8 years, 25 men, mean left ventricular ejection fraction 31 ± 9%) with an old myocardial infarction and multiple and/or hemodynamically not tolerated ventricular tachycardia necessitating repeated device therapy. A total of 31 substrate modification procedures were performed using the three-dimensional electroanatomical mapping system. Patients were followed up for a median of 23.5 (interquartile range 6.5-53.2) months before and 37.8 (interquartile range 11.7-71.8) months after ablation. Antiarrhythmic drugs were not changed after the procedure, and were stopped 6 to 9 months after the procedure in patients who did not show ventricular tachycardia recurrence. Median ventricular tachycardias were 1.6 (interquartile range 0.7-6.7) per month before and 0.2 (interquartile range 0.00-1.3) per month after ablation (P = 0.006). Nine ventricular fibrillation episodes were registered in seven patients before and two after ablation (P = 0.025). Median antitachycardia pacing decreased from 1.6 (interquartile range 0.01-5.5) per month before to 0.18 (interquartile range 0.00-1.6) per month after ablation (P = 0.069). Median number of shocks decreased from 0.19 (interquartile range 0.04-0.81) per month before to 0.00 (interquartile range 0.00-0.09) per month after ablation (P = 0.001). One patient had a transient ischemic attack during the procedure, and another developed pericarditis. Nine patients died during follow-up, eight patients due to heart failure and one patient during valve surgery. Catheter-based substrate modification using voltage mapping results in a long-lasting reduction

  8. Sobredentadura total superior implantosoportada Superior total overdenture on implants

    Directory of Open Access Journals (Sweden)

    Luis Orlando Rodríguez García

    2010-06-01

    Full Text Available Se presenta un caso de un paciente desdentado total superior, rehabilitado en la consulta de implantología de la Clínica "Pedro Ortiz" del municipio Habana del Este en Ciudad de La Habana, Cuba, en el año 2009, mediante prótesis sobre implantes osteointegrados, técnica que se ha incorporado a la práctica estomatológica en Cuba como alternativa al tratamiento convencional en los pacientes desdentados totales. Se siguió un protocolo que comprendió una fase quirúrgica, procedimiento con o sin realización de colgajo y carga precoz o inmediata. Se presenta un paciente masculino de 56 años de edad, que acudió a la consulta multidisciplinaria, preocupado, porque se le habían elaborado tres prótesis en los últimos dos años y ninguna reunía los requisitos de retención que él necesitaba para sentirse seguro y cómodo con las mismas. El resultado final fue la satisfacción total del paciente, con el mejoramiento de la calidad estética y funcional.This is the case of a total maxilla edentulous patient seen in consultation of the "Pedro Ortíz" Clinic Implant of Habana del Este municipality in 2009 and con rehabilitation by prosthesis over osteointegration implants added to stomatology practice in Cuba as an alternative to conventional treatment in patients totally edentulous. We follow a protocol including a surgery or surgical phase, technique without or with flap creation and early or immediate load. This is a male patient aged 56 came to our multidisciplinary consultation worried because he had three prostheses in last two years and any fulfilled the requirements of retention to feel safe and comfortable with prostheses. The final result was the total satisfaction of rehabilitated patient improving its aesthetic and functional quality.

  9. Thoracoscopic Left Cardiac Sympathetic Denervation for a Patient with Catecholaminergic Polymorphic Ventricular Tachycardia and Recurrent Implantable Cardioverter-Defibrillator Shocks

    Directory of Open Access Journals (Sweden)

    Woo-Sik Yu

    2015-06-01

    Full Text Available A patient presented with loss of consciousness and conversion. During an exercise test, catecholaminergic polymorphic ventricular tachycardia (CPVT resulted in cardiac arrest. He started taking medication (a beta-blocker and flecainide and an implantable cardioverter defibrillator (ICD was inserted, but the ventricular tachycardia did not resolve. Left cardiac sympathetic denervation (LCSD was then performed under general anesthesia, and the patient was discharged on the second postoperative day without complications. One month after the operation, no shock had been administered by the ICD, and an exercise stress test did not induce ventricular tachycardia. Although beta- blockers are the gold standard of therapy in patients with CPVT, thoracoscopic LCSD is safe and can be an effective alternative treatment option for patients with intractable CPVT.

  10. Failed anti-tachycardia pacing can be used to differentiate atrial arrhythmias from ventricular tachycardia in implantable cardioverter-defibrillators.

    Science.gov (United States)

    Michael, Kevin A; Enriquez, Andres; Baranchuk, Adrian; Haley, Charlotte; Caldwell, Jane; Simpson, Christopher S; Abdollah, Hoshiar; Redfearn, Damian P

    2015-01-01

    Atrial fibrillation/tachycardia (AF/AT) may result in inappropriate therapies in implantable cardioverter-defibrillators (ICDs). The post-pacing interval (PPI) and tachycardia cycle length difference (PPI - TCL) has been previously demonstrated to indicate the proximity of the pacing site to a tachycardia origin. We postulated that the PPI and PPI - TCL would be greater in AT/AF vs. ventricular tachycardia (VT) after episodes of failed anti-tachycardia pacing (ATP). This was a single-centre, retrospective study evaluating consecutive patients implanted with dual (DR)/biventricular (BIV) ICDs. Stored electrograms were used to determine whether the ATP captured the arrhythmia and the arrhythmia did not present with primary or secondary termination. Measurements were done using manual calipers. A total of 155 patients were included. There were 79 BIV and 76 DR devices. In total, 39 episodes were identified in 20 patients over a 23-month follow-up period. A total of 76 sequences of ATP (burst/ramp) were delivered, 28 (37%) of them inappropriate. Fifty-one events (18 AT/AF and 33 VT) were compared. The mean PPI was 693 ± 96 vs. 512 ± 88 ms (P failed ATP differs significantly between AF/AT and VT and are therefore useful indices to discriminate between supraventricular tachycardia and VT in ICDs. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2014. For permissions please email: journals.permissions@oup.com.

  11. Is the epicardial left ventricular lead implantation an alternative approach to percutaneous attempt in patients with Steinert disease? A case report

    Science.gov (United States)

    PAPA, ANDREA ANTONIO; RAGO, ANNA; PETILLO, ROBERTA; D’AMBROSIO, PAOLA; SCUTIFERO, MARIANNA; FEO, MARISA DE; MAIELLO, CIRO; PALLADINO, ALBERTO

    2017-01-01

    Steinert’s disease or Myotonic Dystrophy type 1 (DM1) is an autosomal dominant multisystemic disorder characterized by myotonia, muscle and facial weakness, cataracts, cognitive, endocrine and gastrointestinal involvement, and cardiac conduction abnormalities. Although mild myocardial dysfunction may be detected in this syndrome with age, overt myocardial dysfunction with heart failure is not frequent. Cardiac resynchronization therapy is an effective treatment to improve morbidity and reduce mortality in patients with DM1 showing intra-ventricular conduction delay and/or congestive heart failure. We report the case of a patient with Steinert disease showing an early onset ventricular dysfunction due to chronic right ventricular apical pacing, in which an epicardial left ventricular lead implantation was performed following the failure of the percutaneous attempt. As no relief in symptoms of heart failure, nor an improvement of left ventricular ejection fraction and reverse remodelling was observed six months later, the patient was addressed to the heart transplantation.

  12. Early Right Ventricular Assist Device Use in Patients Undergoing Continuous-Flow Left Ventricular Assist Device Implantation: Incidence and Risk Factors From the Interagency Registry for Mechanically Assisted Circulatory Support.

    Science.gov (United States)

    Kiernan, Michael S; Grandin, E Wilson; Brinkley, Marshall; Kapur, Navin K; Pham, Duc Thinh; Ruthazer, Robin; Rame, J Eduardo; Atluri, Pavan; Birati, Edo Y; Oliveira, Guilherme H; Pagani, Francis D; Kirklin, James K; Naftel, David; Kormos, Robert L; Teuteberg, Jeffrey J; DeNofrio, David

    2017-10-01

    To investigate preimplant risk factors associated with early right ventricular assist device (RVAD) use in patients undergoing continuous-flow left ventricular assist device (LVAD) surgery. Patients in the Interagency Registry for Mechanically Assisted Circulatory Support who underwent primary continuous-flow-LVAD surgery were examined for concurrent or subsequent RVAD implantation within 14 days of LVAD. Risk factors for RVAD implantation and the combined end point of RVAD or death within 14 days of LVAD were assessed with stepwise logistic regression. We compared survival between patients with and without RVAD using Kaplan-Meier method and Cox proportional hazards modeling. Of 9976 patients undergoing continuous-flow-LVAD implantation, 386 patients (3.9%) required an RVAD within 14 days of LVAD surgery. Preimplant characteristics associated with RVAD use included interagency registry for mechanically assisted circulatory support patient profiles 1 and 2, the need for preoperative extracorporeal membrane oxygenation or renal replacement therapy, severe preimplant tricuspid regurgitation, history of cardiac surgery, and concomitant procedures other than tricuspid valve repair at the time of LVAD. Hemodynamic determinants included elevated right atrial pressure, reduced pulmonary artery pulse pressure, and reduced stroke volume. The final model demonstrated good performance for both RVAD implant (area under the curve, 0.78) and the combined end point of RVAD or death within 14 days (area under the curve, 0.73). Compared with patients receiving an isolated LVAD, patients requiring RVAD had decreased 1- and 6-month survival: 78.1% versus 95.8% and 63.6% versus 87.9%, respectively ( P The need for RVAD implantation after LVAD is associated with indices of global illness severity, markers of end-organ dysfunction, and profiles of hemodynamic instability. © 2017 American Heart Association, Inc.

  13. Arrhythmogenic right ventricular dysplasia: A case report

    Directory of Open Access Journals (Sweden)

    Tessa Negrín Valdés

    2015-10-01

    Full Text Available Arrhythmogenic right ventricular dysplasia is a heart muscle disease that predominantly affects the right ventricle, bringing about the replacement of normal myocardium with fatty or fibrofatty tissue and causing sudden death in young individuals. Ventricular tachycardia is an important clinical manifestation, although there are reports of right or global heart failure. The diagnosis is confirmed by echocardiography and magnetic resonance imaging. The case of a 65-year-old former smoker, with hypertension and ischemic heart disease, a history of effort syncope symptoms and proven non-sustained ventricular tachycardia, with morphology of left bundle branch block, is reported. Relevant diagnostic studies were performed, and echocardiographic elements which were compatible with arrhythmogenic right ventricular dysplasia were found. Therefore, an implantable cardioverter defibrillator was implanted, after which the patient has had a favorable outcome.

  14. The effect of acute mechanical left ventricular unloading on ovine tricuspid annular size and geometry.

    Science.gov (United States)

    Malinowski, Marcin; Wilton, Penny; Khaghani, Asghar; Brown, Michael; Langholz, David; Hooker, Victoria; Eberhart, Lenora; Hooker, Robert L; Timek, Tomasz A

    2016-09-01

    Left ventricular assist device (LVAD) implantation may alter right ventricular shape and function and lead to tricuspid regurgitation. This in turn has been reported to be a determinant of right ventricular (RV) failure after LVAD implantation, but the effect of mechanical left ventricular (LV) unloading on the tricuspid annulus is unknown. The aim of the study was to provide insight into the effect of LVAD support on tricuspid annular geometry and dynamics that may help to optimize LV unloading with the least deleterious effect on the right-sided geometry. In seven open-chest anaesthetized sheep, nine sonomicrometry crystals were implanted on the right ventricle. Additional nine crystals were implanted around the tricuspid annulus, with one crystal at each commissure defining three separate annular regions: anterior, posterior and septal. Left ventricular unloading was achieved by connecting a cannula in the left atrium and the aorta to a continuous-flow pump. The pump was used for 15 min at a full flow of 3.8 ± 0.3 l/min. Epicardial echocardiography was used to assess the degree of tricuspid insufficiency. Haemodynamic, echocardiographic and sonomicrometry data were collected before and during full unloading. Tricuspid annular area, and the regional and total perimeter were calculated from crystal coordinates, while 3D annular geometry was expressed as the orthogonal distance of each annular crystal to the least squares plane of all annular crystals. There was no significant tricuspid regurgitation observed either before or during LV unloading. Right ventricular free wall to septum diameter increased significantly at end-diastole during unloading from 23.6 ± 5.8 to 26.3 ± 6.5 mm (P = 0.009), but the right ventricular volume, tricuspid annular area and total perimeter did not change from baseline. However, the septal part of the annulus significantly decreased its maximal length (38.6 ± 8.1 to 37.9 ± 8.2 mm, P = 0.03). Annular contraction was not altered. The

  15. Effects of Percutaneous LVAD Support on Right Ventricular Load and Adaptation.

    Science.gov (United States)

    Yourshaw, Jeffrey P; Mishra, Prabodh; Armstrong, M Christopher; Ramu, Bhavadharini; Craig, Michael L; Van Bakel, Adrian B; Steinberg, Daniel H; DiSalvo, Thomas G; Tedford, Ryan J; Houston, Brian A

    2018-04-30

    Both operative and hemodynamic mechanisms have been implicated in right heart failure (RHF) following surgical left ventricular assist device (LVAD) implantation. We investigated the effects of percutaneous LVAD (pLVAD; Impella®, Abiomed) support on right ventricular (RV) load and adaptation. We reviewed all patients receiving a pLVAD for cardiogenic shock at our institution between July 2014 and April 2017, including only those with pre- and post-pLVAD invasive hemodynamic measurements. Hemodynamic data was recorded immediately prior to pLVAD implantation and up to 96 h post-implantation. Twenty-five patients were included. Cardiac output increased progressively during pLVAD support. PAWP improved early post-pLVAD but did not further improve during continued support. Markers of RV adaptation (right ventricular stroke work index, right atrial pressure (RAP), and RAP to pulmonary artery wedge pressure ratio (RAP:PAWP)) were unchanged acutely implant but progressively improved during continued pLVAD support. Total RV load (pulmonary effective arterial elastance; E A ) and resistive RV load (pulmonary vascular resistance; PVR) both declined progressively. The relationship between RV load and RV adaptation (E A /RAP and E A /RAP:PAWP) was constant throughout. Median vasoactive-inotrope score declined after pLVAD placement and continued to decline throughout support. Percutaneous LVAD support in patients with cardiogenic shock did not acutely worsen RV adaptation, in contrast to previously described hemodynamic effects of surgically implanted durable LVADs. Further, RV load progressively declined during support, and the noted RV adaptation improvement was load-dependent as depicted by constant E A /RA and E A /RAP:PAWP relationships. These findings further implicate the operative changes associated with surgical LVAD implantation in early RHF following durable LVAD.

  16. Optimizing implantable cardioverter-defibrillator treatment of rapid ventricular tachycardia: antitachycardia pacing therapy during charging.

    Science.gov (United States)

    Schoels, Wolfgang; Steinhaus, David; Johnson, W Ben; O'hara, Gilles; Schwab, Joerg O; Jenniskens, Inge; Degroot, Paul J; Tang, Feng; Helmling, Erhard

    2007-07-01

    Previous studies in implantable cardioverter-defibrillator (ICD) patients demonstrated the efficacy and safety of antitachycardia pacing (ATP) for rapid ventricular tachycardias (VT). To prevent shock delay in case of ATP failure, a new feature (ATP during charging) was developed to deliver ATP for rapid VT while charging for shock. The purpose of this study was to determine the efficacy and safety of this new feature. In a prospective, nonrandomized trial, patients with standard ICD indication received an EnTrust ICD. VT and ventricular fibrillation (VF) episodes were reviewed for appropriate detection, ATP success, rhythm acceleration, and related symptoms. In 421 implanted patients, 116 VF episodes occurred in 37 patients. Eighty-four (72%) episodes received ATP during or before charging. ATP prevented a shock in 58 (69%) of 84 episodes in 15 patients. ATP stopped significantly more monomorphic (77%) than polymorphic VTs (44%, P = .05). Five (6%) episodes accelerated after ATP but were terminated by the backup shock(s). No symptoms were related to ATP during charging. In four patients, 38 charges were saved by delivering ATP before charging. Of 98 induced VF episodes, 28% were successfully terminated by ATP versus 69% for spontaneous episodes (P <.01). Most VTs detected in the VF zone can be painlessly terminated by ATP delivered during charging, with a low risk of acceleration or symptoms. ATP before charging allows delivery of two ATP attempts before shock in the same time that would otherwise be required to deliver only one ATP plus a shock. It also offers potential battery energy savings.

  17. Systemic assessment of patients undergoing dental implant surgeries: A trans- and post-operative analysis

    OpenAIRE

    Sanjay Byakodi; Sachin Kumar; Rajesh Kumar Reddy; Vipin Kumar; Shipra Sepolia; Shivangi Gupta; Harkanwal Preet Singh

    2017-01-01

    Background: Procedure-related and patient-related factors influence the prognosis of dental implants to a major extent. Hence, we aimed to evaluate and analyze various systemic factors in patients receiving dental implants. Materials and Methods: Fifty-one patients were included in the study, in which a total of 110 dental implants were placed. Complete examination of the subjects was done before and after placement of dental implants. Implant surgery was planned, and osseointegrated dental i...

  18. A case of Lamin C gene-mutation with preserved systolic function and ventricular dysrrhythmia

    Directory of Open Access Journals (Sweden)

    Kevin Kit Ng

    2013-02-01

    Full Text Available Lamin A/C gene-related cardiomyopathy is associated with progressive heart failure and malignant arrhythmias. Current guidelines advise the use of implantable defibrillators to prevent arrhythmogenic sudden cardiac death only in situations where there is evidence of severe left ventricular dysfunction. We describe a case of a woman with genetically confirmed Lamin C deficiency with preserved left ventricular function in whom an implantable defibrillator was inserted and within a month of implantation was used to terminate symptomatic ventricular tachycardia.

  19. Ventricular arrhythmias in Chagas disease

    Directory of Open Access Journals (Sweden)

    Marco Paulo Tomaz Barbosa

    2015-02-01

    Full Text Available Sudden death is one of the most characteristic phenomena of Chagas disease, and approximately one-third of infected patients develop life-threatening heart disease, including malignant ventricular arrhythmias. Fibrotic lesions secondary to chronic cardiomyopathy produce arrhythmogenic substrates that lead to the appearance and maintenance of ventricular arrhythmias. The objective of this study is to discuss the main clinical and epidemiological aspects of ventricular arrhythmias in Chagas disease, the specific workups and treatments for these abnormalities, and the breakthroughs needed to determine a more effective approach to these arrhythmias. A literature review was performed via a search of the PubMed database from 1965 to May 31, 2014 for studies of patients with Chagas disease. Clinical management of patients with chronic Chagas disease begins with proper clinical stratification and the identification of individuals at a higher risk of sudden cardiac death. Once a patient develops malignant ventricular arrhythmia, the therapeutic approach aims to prevent the recurrence of arrhythmias and sudden cardiac death by the use of implantable cardioverter defibrillators, antiarrhythmic drugs, or both. In select cases, invasive ablation of the reentrant circuit causing tachycardia may be useful. Ventricular arrhythmias are important manifestations of Chagas cardiomyopathy. This review highlights the absence of high-quality evidence regarding the treatment of ventricular arrhythmias in Chagas disease. Recognizing high-risk patients who require specific therapies, especially invasive procedures such as the implantation of cardioverter defibrillators and ablative approaches, is a major challenge in clinical practice.

  20. Totally implantable venous catheters for chemotherapy: experience in 500 patients

    Directory of Open Access Journals (Sweden)

    Nelson Wolosker

    Full Text Available CONTEXT: Totally implantable devices are increasingly being utilized for chemotherapy treatment of oncological patients, although few studies have been done in our environment to analyze the results obtained from the implantation and utilization of such catheters. OBJECTIVE: To study the results obtained from the implantation of totally implantable catheters in patients submitted to chemotherapy. TYPE OF STUDY: Prospective. SETTING: Hospital do Câncer A.C. Camargo, São Paulo, Brazil. METHODS: 519 totally implantable catheters were placed in 500 patients submitted to chemotherapy, with preference for the use of the right external jugular vein. Evaluations were made of the early and late-stage complications and patient evolution until removal of the device, death or the end of the treatment. RESULTS: The prospective analysis showed an average duration of 353 days for the catheters. There were 427 (82.2% catheters with no complications. Among the early complications observed, there were 15 pathway hematomas, 8 cases of thrombophlebitis of the distal stump of the external jugular vein and one case of pocket infection. Among the late-stage complications observed, there were 43 infectious complications (0.23/1000 days of catheter use, 11 obstructions (0.06/1000 days of catheter use and 14 cases of deep vein thrombosis (0.07/1000 days of catheter use. Removal of 101 catheters was performed: 35 due to complications and 66 upon terminating the treatment. A total of 240 patients died while the catheter was functioning and 178 patients are still making use of the catheter. CONCLUSION: The low rate of complications obtained in this study confirms the safety and convenience of the use of totally implantable accesses in patients undergoing prolonged chemotherapy regimes.

  1. Amiodarone for the treatment and prevention of ventricular fibrillation and ventricular tachycardia

    Directory of Open Access Journals (Sweden)

    Hugo Van Herendael

    2010-06-01

    Full Text Available Hugo Van Herendael, Paul DorianDivision of Cardiology, St. Michael’s Hospital, University of Toronto, Toronto, CanadaAbstract: Amiodarone has emerged as the leading antiarrhythmic therapy for termination and prevention of ventricular arrhythmia in different clinical settings because of its proven efficacy and safety. In patients with shock refractory out-of-hospital cardiac arrest and hemodynamically destabilizing ventricular arrhythmia, amiodarone is the most effective drug available to assist in resuscitation. Although the superiority of the transvenous implantable cardioverter defibrillator (ICD over amiodarone has been well established in the preventive treatment of patients at high risk of life-threatening ventricular arrhythmias, amiodarone (if used with a beta-blocker is the most effective antiarrhythmic drug to prevent ICD shocks and treat electrical storm. Both the pharmacokinetics and the electrophysiologic profile of amiodarone are complex, and its optimal and safe use requires careful patient surveillance with respect to potential adverse effects.Keywords: amiodarone, ventricular fibrillation, unstable ventricular tachycardia

  2. Right ventricular remodelling after transcatheter pulmonary valve implantation.

    Science.gov (United States)

    Pagourelias, Efstathios D; Daraban, Ana M; Mada, Razvan O; Duchenne, Jürgen; Mirea, Oana; Cools, Bjorn; Heying, Ruth; Boshoff, Derize; Bogaert, Jan; Budts, Werner; Gewillig, Marc; Voigt, Jens-Uwe

    2017-09-01

    To define the optimal timing for percutaneous pulmonary valve implantation (PPVI) in patients with severe pulmonary regurgitation (PR) after Fallot's Tetralogy (ToF) correction. PPVI among the aforementioned patients is mainly driven by symptoms or by severe right ventricular (RV) dilatation/dysfunction. The optimal timing for PPVI is still disputed. Twenty patients [age 13.9 ± 9.2 years, (range 4.3-44.9), male 70%] with severe PR (≥3 grade) secondary to previous correction of ToF, underwent Melody valve (Medtronic, Minneapolis, MN) implantation, after a pre-stent placement. Full echocardiographic assessment (traditional and deformation analysis) and cardiovascular magnetic resonance evaluation were performed before and at 3 months after the intervention. 'Favorable remodelling' was considered the upper quartile of RV size decrease (>20% in 3 months). After PPVI, indexed RV effective stroke volume increased from 38.4 ± 9.5 to 51.4 ± 10.7 mL/m 2 , (P = 0.005), while RV end-diastolic volume and strain indices decreased (123.1 ± 24.1-101.5 ± 18.3 mL/m 2 , P = 0.005 and -23.5 ± 2.5 to -21 ± 2.5%, P = 0.002, respectively). After inserting pre-PPVI clinical, RV volumetric and deformation parameters in a multiple regression model, only time after last surgical correction causing PR remained as significant regressor of RV remodelling [R 2  = 0.60, beta = 0.387, 95%CI(0.07-0.7), P = 0.019]. Volume reduction and functional improvement were more pronounced in patients treated with PPVI earlier than 7 years after last RV outflow tract (RVOT) correction, reaching close-to-normal values. Early PPVI (<7 years after last RVOT operation) is associated with a more favorable RV reverse remodelling toward normal range and should be considered, before symptoms or RV damage become apparent. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  3. Arrhythmogenic Right Ventricular Cardiomyopathy: Risk Stratification and Indications for Defibrillator Therapy.

    Science.gov (United States)

    Zorzi, Alessandro; Rigato, Ilaria; Bauce, Barbara; Pilichou, Kalliopi; Basso, Cristina; Thiene, Gaetano; Iliceto, Sabino; Corrado, Domenico

    2016-06-01

    Arrhythmogenic right ventricular cardiomyopathy (ARVC) is a genetically determined disease which predisposes to life-threatening ventricular arrhythmias. The main goal of ARVC therapy is prevention of sudden cardiac death (SCD). Implantable cardioverter defibrillator (ICD) is the most effective therapy for interruption of potentially lethal ventricular tachyarrhythmias. Despite its life-saving potential, ICD implantation is associated with a high rate of complications and significant impact on quality of life. Accurate risk stratification is needed to identify individuals who most benefit from the therapy. While there is general agreement that patients with a history of cardiac arrest or hemodynamically unstable ventricular tachycardia are at high risk of SCD and needs an ICD, indications for primary prevention remain a matter of debate. The article reviews the available scientific evidence and guidelines that may help to stratify the arrhythmic risk of ARVC patients and guide ICD implantation. Other therapeutic strategies, either alternative or additional to ICD, will be also addressed.

  4. Poorer survival after a primary implant during revision total knee arthroplasty

    NARCIS (Netherlands)

    Meijer, Marrigje F.; Reininga, Inge H. F.; Boerboom, Alexander L.; Stevens, Martin; Bulstra, Sjoerd K.

    Revision total knee arthroplasty (rTKA) is a complex procedure. Depending on the degree of ligament and bone damage, either primary or revision implants are used. The purpose of this study was to compare survival rates of primary implants with revision implants when used during rTKA. A retrospective

  5. Efeitos da estimulação ventricular convencional em pacientes com função ventricular normal Efectos de la estimulación ventricular convencional en pacientes con función ventricular normal Conventional ventricular stimulation effects on patients with normal ventricular function

    Directory of Open Access Journals (Sweden)

    Luiz Antonio Batista de Sá

    2009-08-01

    Full Text Available FUNDAMENTO: A estimulação de ventrículo direito pode ser deletéria em pacientes com disfunção ventricular, entretanto há poucas evidências sobre o impacto dessa estimulação em pacientes com função normal. OBJETIVO: Avaliar a evolução clínica e laboratorial de pacientes com função ventricular normal submetidos a implante de marcapasso cardíaco artificial. MÉTODOS: Foram estudados de forma prospectiva 16 pacientes com os seguintes critérios de inclusão: função ventricular normal definida pelo ecocardiograma e presença de estimulação ventricular superior 90% (avaliação por telemetria do gerador. Parâmetros analisados: classe funcional (CF, teste de caminhada, dosagem de BNP, ecocardiograma (convencional e parâmetros de dessincronia intraventricular e teste de qualidade de vida (SF36. Essas medidas fora feitas com 10 dias(d (t1, 120d(t2 e 240 d(t3. Os dados foram comparados ao longo do tempo segundo método ANOVA. Comparações múltiplas de médias foram efetuadas utilizando-se o método de Tukey. RESULTADOS: Dos dados avaliados os seguintes não apresentaram variação estatística significante (p>0,05: classe funcional, dosagem de BNP, parâmetros ecocardiográficos convencionais, dessincronia intraventricular (Doppler tecidual. Apresentaram piora (pFUNDAMENTO: La estimulación del ventrículo derecho puede ser dañosa a pacientes con disfunción ventricular. Sin embargo, hay pocas evidencias sobre el impacto de esa estimulación en pacientes con función normal. OBJETIVO: Evaluar la evolución clínica y laboratorial de pacientes con función ventricular normal sometidos a implante de marcapaso cardíaco artificial. MÉTODOS: Se estudiaron de forma prospectiva a 16 pacientes con los siguientes criterios de inclusión: función ventricular normal definida por el ecocardiograma y presencia de estimulación ventricular superior a 90% (evaluación por telemetría del generador. Parámetros analizados: clase funcional

  6. The role of cerebral hyperperfusion in postoperative neurologic dysfunction after left ventricular assist device implantation for end-stage heart failure.

    Science.gov (United States)

    Lietz, Katherine; Brown, Kevin; Ali, Syed S; Colvin-Adams, Monica; Boyle, Andrew J; Anderson, David; Weinberg, Alan D; Miller, Leslie W; Park, Soon; John, Ranjit; Lazar, Ronald M

    2009-04-01

    Cerebral hyperperfusion is a life-threatening syndrome that can occur in patients with chronically hypoperfused cerebral vasculature whose normal cerebral circulation was re-established after carotid endarterectomy or angioplasty. We sought to determine whether the abrupt restoration of perfusion to the brain after left ventricular assist device (LVAD) implantation produced similar syndromes. We studied the role of increased systemic flow after LVAD implantation on neurologic dysfunction in 69 consecutive HeartMate XVE LVAD (Thoratec, Pleasanton, Calif) recipients from October 2001 through June 2006. Neurologic dysfunction was defined as postoperative permanent or transient central change in neurologic status, including confusion, focal neurologic deficits, visual changes, seizures, or coma for more than 24 hours within 30 days after LVAD implantation. We found that 19 (27.5%) patients had neurologic dysfunction, including encephalopathy (n = 11), coma (n = 3), and other complications (n = 5). The multivariate analysis showed that an increase in cardiac index from the preoperative baseline value (relative risk, 1.33 per 25% cardiac index increase; P = .01) and a previous coronary bypass operation (relative risk, 4.53; P = .02) were the only independent predictors of neurologic dysfunction. Reduction of left ventricular assist device flow in 16 of the 19 symptomatic patients led to improvement of symptoms in 14 (87%) patients. Our findings showed that normal flow might overwhelm cerebral autoregulation in patients with severe heart failure, suggesting that cerebral hyperperfusion is possible in recipients of mechanical circulatory support with neurologic dysfunction.

  7. Ventricular Effective Refraction Period and Ventricular Repolarization Analysis in Experimental Tachycardiomyopathy in Swine.

    Science.gov (United States)

    Noszczyk-Nowak, Agnieszka; Pasławska, Urszula; Gajek, Jacek; Janiszewski, Adrian; Pasławski, Robert; Zyśko, Dorota; Nicpoń, Józef

    2016-01-01

    Swine are recognized animal models of human cardiovascular diseases. However, little is known on the CHF-associated changes in the electrophysiological ventricular parameters of humans and animals. The aim of this study was to analyze changes in the durations of ventricular effective refraction period (VERP), QT and QTc intervals of pigs with chronic tachycardia-induced tachycardiomyopathy (TIC). The study was comprised of 28 adult pigs (8 females and 20 males) of the Polish Large White breed. A one-chamber pacemaker was implanted in each of the 28 pigs. Electrocardiographic, echocardiographic and electrophysiological studies were carried out prior to the pacemaker implantation and at subsequent 4-week intervals. All electrocardiographic, echocardiographic and short electrophysiological study measurements in all swine were done under general anesthesia (propofol) after premedication with midazolam, medetomidine, and ketamine. No significant changes in the duration of QT interval and corrected QT interval (QTc) were observed during consecutive weeks of the experiment. The duration of the QTc interval of female pigs was shown to be significantly longer than that of the males throughout the whole study period. Beginning from the 12th week of rapid ventricular pacing, a significant increase in duration of VERP was observed in both male and female pigs. Males and females did not differ significantly in terms of VERP duration determined throughout the whole study period. Ventricular pacing, stimulation with 2 and 3 premature impulses at progressively shorter coupling intervals and an imposed rhythm of 130 bpm or 150 bpm induced transient ventricular tachycardia in one female pig and four male pigs. One episode of permanent ventricular tachycardia was observed. The number of induced arrhythmias increased proportionally to the severity of heart failure and duration of the experiment. However, relatively aggressive protocols of stimulation were required in order to induce

  8. Hybrid approach of ventricular assist device and autologous bone marrow stem cells implantation in end-stage ischemic heart failure enhances myocardial reperfusion

    Directory of Open Access Journals (Sweden)

    Khayat Andre

    2011-01-01

    Full Text Available Abstract We challenge the hypothesis of enhanced myocardial reperfusion after implanting a left ventricular assist device together with bone marrow mononuclear stem cells in patients with end-stage ischemic cardiomyopathy. Irreversible myocardial loss observed in ischemic cardiomyopathy leads to progressive cardiac remodelling and dysfunction through a complex neurohormonal cascade. New generation assist devices promote myocardial recovery only in patients with dilated or peripartum cardiomyopathy. In the setting of diffuse myocardial ischemia not amenable to revascularization, native myocardial recovery has not been observed after implantation of an assist device as destination therapy. The hybrid approach of implanting autologous bone marrow stem cells during assist device implantation may eventually improve native cardiac function, which may be associated with a better prognosis eventually ameliorating the need for subsequent heart transplantation. The aforementioned hypothesis has to be tested with well-designed prospective multicentre studies.

  9. Total Artificial Heart Implantation After Undifferentiated High-Grade Sarcoma Excision.

    Science.gov (United States)

    Kremer, Jamila; Farag, Mina; Arif, Rawa; Brcic, Andreas; Sabashnikov, Anton; Schmack, Bastian; Popov, Aron-Frederik; Karck, Matthias; Dohmen, Pascal M; Ruhparwar, Arjang; Weymann, Alexander

    2016-11-02

    BACKGROUND Total artificial heart (TAH) implantation in patients with aggressive tumor infiltration of the heart can be challenging. CASE REPORT We report on a patient with a rare primary undifferentiated high-grade spindle cell sarcoma of the mitral valve and in the left atrium, first diagnosed in 2014. The referring center did a first resection in 2014. In the course of 17 months, computer tomography (CT) scan again showed massive invasion of the mitral valve and left atrium. Partial resection and mitral valve replacement was not an option. We did a subtotal heart excision with total artificial heart implantation. In this report we discuss complications, risk factors, and perioperative management of this patient. CONCLUSIONS Patients with aggressive tumors of the heart can be considered for TAH implantation.

  10. Incidence of postoperative implant-related bacterial endocarditis in dogs that underwent trans-catheter embolization of a patent ductus arteriosus without intra- and post-procedural prophylactic antibiotics

    NARCIS (Netherlands)

    Szatmári, Viktor

    2017-01-01

    Intra- and post-procedural prophylactic antibiotics are routinely administered by veterinary cardiologists to dogs that undergo trans-catheter embolization of a patent ductus arteriosus for prevention of implant-related infective endocarditis. The hypothesis of our study was that primary antibiotic

  11. Moderate hypothermia technique for chronic implantation of a total artificial heart in calves.

    Science.gov (United States)

    Karimov, Jamshid H; Grady, Patrick; Sinkewich, Martin; Sunagawa, Gengo; Dessoffy, Raymond; Byram, Nicole; Moazami, Nader; Fukamachi, Kiyotaka

    2017-06-01

    The benefit of whole-body hypothermia in preventing ischemic injury during cardiac surgical operations is well documented. However, application of hypothermia during in vivo total artificial heart implantation has not become widespread because of limited understanding of the proper techniques and restrictions implied by constitutional and physiological characteristics specific to each animal model. Similarly, the literature on hypothermic set-up in total artificial heart implantation has also been limited. Herein we present our experience using hypothermia in bovine models implanted with the Cleveland Clinic continuous-flow total artificial heart.

  12. Total artificial heart implantation in a young Marfan syndrome patient.

    Science.gov (United States)

    Rao, Prashant; Keenan, Jack B; Rajab, Taufiek K; Kim, Samuel; Smith, Richard; Amabile, Orazio; Khalpey, Zain

    2018-03-01

    Cardiovascular complications represent the leading cause of morbidity and mortality in patients with Marfan syndrome. Here, we describe a unique case where a total artificial heart was implanted in a young Marfan syndrome woman. A 22-year-old postpartum African American female with Marfan syndrome developed multiple severe valve dysfunction and biventricular failure that was refractory to medical management. She previously had a Bentall procedure for Type A aortic dissection and repair of a Type B dissection. We implanted a total artificial heart with a good outcome. Total artificial heart is a durable option for severe biventricular failure and multiple valvular dysfunction as a bridge to transplant in a young patient with Marfan syndrome.

  13. Worldwide experience with a totally subcutaneous implantable defibrillator

    DEFF Research Database (Denmark)

    Lambiase, Pier D; Barr, Craig; Theuns, Dominic A M J

    2014-01-01

    AIMS: The totally subcutaneous implantable-defibrillator (S-ICD) is a new alternative to the conventional transvenous ICD system to minimize intravascular lead complications. There are limited data describing the long-term performance of the S-ICD. This paper presents the first large internationa...

  14. Strategies for reducing implant costs in the revision total knee arthroplasty episode of care.

    Science.gov (United States)

    Elbuluk, Ameer M; Old, Andrew B; Bosco, Joseph A; Schwarzkopf, Ran; Iorio, Richard

    2017-12-01

    Implant price has been identified as a significant contributing factor to high costs associated with revision total knee arthroplasty (rTKA). The goal of this study is to analyze the cost of implants used in rTKAs and to compare this pricing with 2 alternative pricing models. Using our institutional database, we identified 52 patients from January 1, 2014 to December 31, 2014. Average cost of components for each case was calculated and compared to the total hospital cost for that admission. Costs for an all-component revision were then compared to a proposed "direct to hospital" (DTH) standardized pricing model and a fixed price revision option. Potential savings were calculated from these figures. On average, 28% of the total hospital cost was spent on implants for rTKA. The average cost for revision of all components was $13,640 and ranged from $3000 to $28,000. On average, this represented 32.7% of the total hospital cost. Direct to hospital implant pricing could potentially save approximately $7000 per rTKA, and the fixed pricing model could provide a further $1000 reduction per rTKA-potentially saving $8000 per case on implants alone. Alternative implant pricing models could help lower the total cost of rTKA, which would allow hospitals to achieve significant cost containment.

  15. Ethical challenges with the left ventricular assist device as a destination therapy

    Directory of Open Access Journals (Sweden)

    Rady Mohamed Y

    2008-08-01

    Full Text Available Abstract The left ventricular assist device was originally designed to be surgically implanted as a bridge to transplantation for patients with chronic end-stage heart failure. On the basis of the REMATCH trial, the US Food and Drug Administration and the US Centers for Medicare & Medicaid Services approved permanent implantation of the left ventricular assist device as a destination therapy in Medicare beneficiaries who are not candidates for heart transplantation. The use of the left ventricular assist device as a destination therapy raises certain ethical challenges. Left ventricular assist devices can prolong the survival of average recipients compared with optimal medical management of chronic end-stage heart failure. However, the overall quality of life can be adversely affected in some recipients because of serious infections, neurologic complications, and device malfunction. Left ventricular assist devices alter end-of-life trajectories. The caregivers of recipients may experience significant burden (e.g., poor physical health, depression, anxiety, and posttraumatic stress disorder from destination therapy with left ventricular assist devices. There are also social and financial ramifications for recipients and their families. We advocate early utilization of a palliative care approach and outline prerequisite conditions so that consenting for the use of a left ventricular assist device as a destination therapy is a well informed process. These conditions include: (1 direct participation of a multidisciplinary care team, including palliative care specialists, (2 a concise plan of care for anticipated device-related complications, (3 careful surveillance and counseling for caregiver burden, (4 advance-care planning for anticipated end-of-life trajectories and timing of device deactivation, and (5 a plan to address the long-term financial burden on patients, families, and caregivers. Short-term mechanical circulatory devices (e

  16. The effect of heart failure and left ventricular assist device treatment on right ventricular mechanics: a computational study.

    Science.gov (United States)

    Park, Jun I K; Heikhmakhtiar, Aulia Khamas; Kim, Chang Hyun; Kim, Yoo Seok; Choi, Seong Wook; Song, Kwang Soup; Lim, Ki Moo

    2018-05-22

    Although it is important to analyze the hemodynamic factors related to the right ventricle (RV) after left ventricular assist device (LVAD) implantation, previous studies have focused only on the alteration of the ventricular shape and lack quantitative analysis of the various hemodynamic parameters. Therefore, we quantitatively analyzed various hemodynamic parameters related to the RV under normal, heart failure (HF), and HF incorporated with continuous flow LVAD therapy by using a computational model. In this study, we combined a three-dimensional finite element electromechanical model of ventricles, which is based on human ventricular morphology captured by magnetic resonance imaging (MRI) with a lumped model of the circulatory system and continuous flow LVAD function in order to construct an integrated model of an LVAD implanted-cardiovascular system. To induce systolic dysfunction, the magnitude of the calcium transient function under HF condition was reduced to 70% of the normal value, and the time constant was reduced by 30% of the normal value. Under the HF condition, the left ventricular end systolic pressure decreased, the left ventricular end diastolic pressure increased, and the pressure in the right atrium (RA), RV, and pulmonary artery (PA) increased compared with the normal condition. The LVAD therapy decreased the end-systolic pressure of the LV by 41%, RA by 29%, RV by 53%, and PA by 71%, but increased the right ventricular ejection fraction by 52% and cardiac output by 40%, while the stroke work was reduced by 67% compared with the HF condition without LVAD. The end-systolic ventricular tension and strain decreased with the LVAD treatment. LVAD enhances CO and mechanical unloading of the LV as well as those of the RV and prevents pulmonary hypertension which can be induced by HF.

  17. Incidence of postoperative implant-related bacterial endocarditis in dogs that underwent trans-catheter embolization of a patent ductus arteriosus without intra- and post-procedural prophylactic antibiotics.

    Science.gov (United States)

    Szatmári, Viktor

    2017-08-01

    Intra- and post-procedural prophylactic antibiotics are routinely administered by veterinary cardiologists to dogs that undergo trans-catheter embolization of a patent ductus arteriosus for prevention of implant-related infective endocarditis. The hypothesis of our study was that primary antibiotic prophylaxis is not necessary to prevent bacterial endocarditis. In this retrospective case series 54 client-owned dogs that underwent trans-catheter occlusion of a patent ductus arteriosus in a single tertiary veterinary referral center between 2004 and 2016 were evaluated. Follow-up information was gained by telephone interviews with the owners or the referring veterinarians, or from the digital archives of the authors' clinic. Inclusion criteria were that at least one metal implant (a coil or an Amplatz duct occluder) had to be delivered in the ductal ampulla, no local or systemic antibiotics were given on the day of the intervention or the week thereafter, at least 3 months of postoperative follow-up information was available, and the author was performing the procedure either as the primary or as the supervising cardiology specialist. None of the 54 dogs developed infective endocarditis in the postoperative 3 months. A study describing a similar population reports 2 of the included 47 dogs having developed infective endocarditis in the postoperative period despite the administration of intra- and post-procedural prophylactic antibiotics. We conclude that intra- and post-procedural antibiotic prophylaxis is not justified in dogs that undergo trans-catheter closure of a patent ductus arteriosus. Proper surgical technique and the use of new sterile catheters and implants are sufficient to prevent infective endocarditis in these dogs. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. New strict left bundle branch block criteria reflect left ventricular activation differences

    DEFF Research Database (Denmark)

    Emerek, Kasper Janus Grønn; Risum, Niels; Hjortshøj, Søren Pihlkjær

    2015-01-01

    AIMS: Pacing lead electrical delays and strict left bundle branch block (LBBB) criteria were assessed against cardiac resynchronization therapy (CRT) outcome. METHODS: Forty-nine patients with LBBB and QRS duration >130 milliseconds underwent CRT-implantation. Sensed right ventricular to left ven....... CONCLUSION: Interventricular electrical delay predicts left ventricular remodeling after CRT and new, strict ECG criteria of LBBB are superior in predicting remodeling.......AIMS: Pacing lead electrical delays and strict left bundle branch block (LBBB) criteria were assessed against cardiac resynchronization therapy (CRT) outcome. METHODS: Forty-nine patients with LBBB and QRS duration >130 milliseconds underwent CRT-implantation. Sensed right ventricular to left...... ventricular electrical delay (RV-LV-IED) was measured. Response to CRT was defined as ≥15% decrease in left ventricular end-systolic volume. RESULTS: Eighteen of 20 (90%) patients with non-ischemic dilated cardiomyopathy (DCM) and 18 of 29 (62%) with ischemic heart disease (IHD) responded to CRT, p

  19. Frailty and outcomes after implantation of left ventricular assist device as destination therapy.

    Science.gov (United States)

    Dunlay, Shannon M; Park, Soon J; Joyce, Lyle D; Daly, Richard C; Stulak, John M; McNallan, Sheila M; Roger, Véronique L; Kushwaha, Sudhir S

    2014-04-01

    Frailty is recognized as a major prognostic indicator in heart failure. There has been interest in understanding whether pre-operative frailty is associated with worse outcomes after implantation of a left ventricular assist device (LVAD) as destination therapy. Patients undergoing LVAD implantation as destination therapy at the Mayo Clinic, Rochester, Minnesota, from February 2007 to June 2012, were included in this study. Frailty was assessed using the deficit index (31 impairments, disabilities and comorbidities) and defined as the proportion of deficits present. We divided patients based on tertiles of the deficit index (>0.32 = frail, 0.23 to 0.32 = intermediate frail, <0.23 = not frail). Cox proportional hazard regression models were used to examine the association between frailty and death. Patients were censored at death or last follow-up through October 2013. Among 99 patients (mean age 65 years, 18% female, 55% with ischemic heart failure), the deficit index ranged from 0.10 to 0.65 (mean 0.29). After a mean follow-up of 1.9 ± 1.6 years, 79% of the patients had been rehospitalized (range 0 to 17 hospitalizations, median 1 per person) and 45% had died. Compared with those who were not frail, patients who were intermediate frail (adjusted HR 1.70, 95% CI 0.71 to 4.31) and frail (HR 3.08, 95% CI 1.40 to 7.48) were at increased risk for death (p for trend = 0.004). The mean (SD) number of days alive out of hospital the first year after LVAD was 293 (107) for not frail, 266 (134) for intermediate frail and 250 (132) for frail patients. Frailty before destination LVAD implantation is associated with increased risk of death and may represent a significant patient selection consideration. Copyright © 2014 International Society for Heart and Lung Transplantation. Published by Elsevier Inc. All rights reserved.

  20. Systemic Assessment of Patients Undergoing Dental Implant Surgeries: A Trans- and Post-operative Analysis.

    Science.gov (United States)

    Byakodi, Sanjay; Kumar, Sachin; Reddy, Rajesh Kumar; Kumar, Vipin; Sepolia, Shipra; Gupta, Shivangi; Singh, Harkanwal Preet

    2017-01-01

    Procedure-related and patient-related factors influence the prognosis of dental implants to a major extent. Hence, we aimed to evaluate and analyze various systemic factors in patients receiving dental implants. Fifty-one patients were included in the study, in which a total of 110 dental implants were placed. Complete examination of the subjects was done before and after placement of dental implants. Implant surgery was planned, and osseointegrated dental implants were placed in the subjects. Postoperative evaluation of the dental implant patients was done after 3 weeks. Anxiety levels were determined using State-Trait Anxiety Inventory (STAI) questionnaire on the surgery day and after 1 week of surgery. The participant describes how they feel at the moment by responding to twenty items as follows: (1) absolutely not, (2) slightly, (3) somewhat, or (4) very much. All the results were recorded and statistical analyzed by SPSS software. Out of 51, 29 patients were males while 22 were females, with ratio of 1.32:1. Female patients' mean age was 50.18 years while male patients' mean age was 52.71 years, with statistically nonsignificant difference between them. Functional rehabilitation was the main purpose of choosing dental implants in more than 90% of the subjects. Diameter of 3.75 mm was the shortest implants to be placed in the present study, whereas in terms of length, 8.5 mm was the shortest length of dental implant used in the present study. Tooth area in which maximum implants were placed in our study was 36 tooth region. Maximum implants were placed in Type II bone quality ( n = 38). Implants installed in the mandible were clamped more efficiently than implants placed in the maxilla ( P < 0.001). The difference of average STAI-State subscore before and after the surgery was statistically significant ( P < 0.05; significant). Mandibular dental implants show more clamping (torque) than maxillary dental implants.

  1. Systemic assessment of patients undergoing dental implant surgeries: A trans- and post-operative analysis

    Directory of Open Access Journals (Sweden)

    Sanjay Byakodi

    2017-01-01

    Full Text Available Background: Procedure-related and patient-related factors influence the prognosis of dental implants to a major extent. Hence, we aimed to evaluate and analyze various systemic factors in patients receiving dental implants. Materials and Methods: Fifty-one patients were included in the study, in which a total of 110 dental implants were placed. Complete examination of the subjects was done before and after placement of dental implants. Implant surgery was planned, and osseointegrated dental implants were placed in the subjects. Postoperative evaluation of the dental implant patients was done after 3 weeks. Anxiety levels were determined using State-Trait Anxiety Inventory (STAI questionnaire on the surgery day and after 1 week of surgery. The participant describes how they feel at the moment by responding to twenty items as follows: (1 absolutely not, (2 slightly, (3 somewhat, or (4 very much. All the results were recorded and statistical analyzed by SPSS software. Results: Out of 51, 29 patients were males while 22 were females, with ratio of 1.32:1. Female patients' mean age was 50.18 years while male patients' mean age was 52.71 years, with statistically nonsignificant difference between them. Functional rehabilitation was the main purpose of choosing dental implants in more than 90% of the subjects. Diameter of 3.75 mm was the shortest implants to be placed in the present study, whereas in terms of length, 8.5 mm was the shortest length of dental implant used in the present study. Tooth area in which maximum implants were placed in our study was 36 tooth region. Maximum implants were placed in Type II bone quality (n = 38. Implants installed in the mandible were clamped more efficiently than implants placed in the maxilla (P < 0.001. The difference of average STAI-State subscore before and after the surgery was statistically significant (P < 0.05; significant. Conclusion: Mandibular dental implants show more clamping (torque than maxillary

  2. A case of short-coupled premature ventricular beat-induced ventricular fibrillation with early repolarization in the inferolateral leads

    Directory of Open Access Journals (Sweden)

    Hidekazu Kondo, MD

    2015-02-01

    Full Text Available This case report describes a 19-year-old man with early repolarization (ER in the inferolateral leads and a normal QT interval who survived a cardiac arrest that was likely related to polymorphic ventricular tachycardia (VT. Electrocardiograms (ECGs also showed unifocal premature ventricular beats (PVBs with a relatively narrow QRS duration. A Holter ECG documented occasional short-coupled PVBs following non-sustained VTs. Pharmacological stress testing was also performed to assess the effects of anti-arrhythmic drugs on ER (the J wave and PVBs. We performed successful radiofrequency catheter ablation to prevent the recurrence of ventricular fibrillation after cardioverter-defibrillator implantation.

  3. Continuous ambulatory right heart pressure measurements with an implantable hemodynamic monitor: a multicenter, 12-month follow-up study of patients with chronic heart failure.

    Science.gov (United States)

    Magalski, Anthony; Adamson, Philip; Gadler, Frederick; Böehm, Michael; Steinhaus, David; Reynolds, Dwight; Vlach, Kathryn; Linde, Cecilia; Cremers, Bodo; Sparks, Brandon; Bennett, Tom

    2002-04-01

    We describe the performance of an implantable hemodynamic monitor (IHM) that allows continuous recording of heart rate, patient activity levels, and right ventricular systolic, right ventricular diastolic, and estimated pulmonary artery diastolic pressures. Pressure parameters derived from the implantable monitor were correlated to measurements made with a balloon-tipped catheter to establish accuracy and reproducibility over time in patients with chronic heart failure (CHF). IHM devices were implanted in 32 patients with CHF (left ventricular ejection fraction, 29% +/- 11%; range, 14%-62%) and were tested with right heart catheterization at implantation and 3, 6, and 12 months later. Hemodynamic variables were digitally recorded simultaneously from the IHM and catheter. Values were recorded during supine rest, peak response of Valsalva maneuver, sitting, peak of a 2-stage (25-50 W) bicycle exercise test, and final rest period. The median of 21 paired beat-to-beat cardiac cycles was analyzed for each intervention. A total of 217 paired data values from all maneuvers were analyzed for 32 patients at implantation and 129 paired data values for 20 patients at 1 year. The IHM and catheter values were not different at baseline or at 1 year (P >.05). Combining all interventions, correlation coefficients were 0.96 and 0.94 for right ventricular systolic pressure, 0.96 and 0.83 for right ventricular diastolic pressure, and 0.87 and 0.87 for estimated pulmonary artery diastolic pressure at implantation and 1 year, respectively. The IHM and a standard reference pressure system recorded comparable right heart pressure values in patients with CHF. This implantable pressure transducer is accurate over time and provides a means to precisely monitor the hemodynamic condition of patients with CHF in a continuous fashion.

  4. Early Right Ventricular Apical Pacing-Induced Gene Expression Alterations Are Associated with Deterioration of Left Ventricular Systolic Function

    Directory of Open Access Journals (Sweden)

    Haiyan Xu

    2017-01-01

    Full Text Available The chronic high-dose right ventricular apical (RVA pacing may have deleterious effects on left ventricular (LV systolic function. We hypothesized that the expression changes of genes regulating cardiomyocyte energy metabolism and contractility were associated with deterioration of LV function in patients who underwent chronic RVA pacing. Sixty patients with complete atrioventricular block and preserved ejection fraction (EF who underwent pacemaker implantation were randomly assigned to either RVA pacing (n=30 group or right ventricular outflow tract (RVOT pacing (n=30 group. The mRNA levels of OPA1 and SERCA2a were significantly lower in the RVA pacing group at 1 month’s follow-up (both p<0.001. Early changes in the expression of selected genes OPA1 and SERCA2a were associated with deterioration in global longitudinal strain (GLS that became apparent months later (p=0.002 and p=0.026, resp. The altered expressions of genes that regulate cardiomyocyte energy metabolism and contractility measured in the peripheral blood at one month following pacemaker implantation were associated with subsequent deterioration in LV dyssynchrony and function in patients with preserved LVEF, who underwent RVA pacing.

  5. Does the Implantation Technique for Totally Implantable Venous Access Ports (TIVAPs) Influence Long-Term Outcome?

    Science.gov (United States)

    Biacchi, Daniele; Sammartino, Paolo; Sibio, Simone; Accarpio, Fabio; Cardi, Maurizio; Sapienza, Paolo; De Cesare, Alessandro; Atta, Joseph Maher Fouad; Impagnatiello, Alessio; Di Giorgio, Angelo

    2016-02-01

    Totally implantable venous access ports (TIVAP) are eventually explanted for various reasons, related or unrelated to the implantation technique used. Having more information on long-term explantation would help improve placement techniques. From a series of 1572 cancer patients who had TIVAPs implanted in our center with the cutdown technique or Seldinger technique, we studied the 542 patients who returned to us to have their TIVAP explanted after 70 days or more. As outcome measures we distinguished between TIVAPs explanted for long-term complications (infection, catheter-, reservoir-, and patient-related complications) and TIVAPs no longer needed. Univariate and multivariate analyses were run to investigate the reasons for explantation and their possible correlation with implantation techniques. The most common reason for explantation was infection (47.6 %), followed by catheter-related (20.8 %), patient-related (14.7 %), and reservoir-related complications (4.7 %). In the remaining 12.2 % of cases, the TIVAP was explanted complication free after the planned treatments ended. Infection correlated closely with longer TIVAP use. Univariate and multivariate analyses identified the Seldinger technique as a major risk factor for venous thrombosis and catheter dislocation. The need for long-term TIVAP explantation in about one-third of cancer patients is related to the implantation techniques used.

  6. Surgical treatment of tricuspid valve insufficiency promotes early reverse remodeling in patients with axial-flow left ventricular assist devices.

    Science.gov (United States)

    Maltais, Simon; Topilsky, Yan; Tchantchaleishvili, Vakhtang; McKellar, Stephen H; Durham, Lucian A; Joyce, Lyle D; Daly, Richard C; Park, Soon J

    2012-06-01

    The HeartMate II (Thoratec Corp, Pleasanton, Calif) continuous-flow left ventricular assist device has emerged as the standard of care for patients with advanced heart failure. The objective of this study was to assess the safety and early effectiveness of concomitant tricuspid valve procedures in patients undergoing implantation of a HeartMate II device. From February 2007 to April 2010, 83 patients underwent HeartMate II left ventricular assist device implantation. Of these, 37 patients had concomitant tricuspid valve procedures (32 repairs, 5 replacements) for severe tricuspid regurgitation. The effects of a tricuspid valve procedure on tricuspid regurgitation and right ventricular remodeling were assessed comparing echocardiographic findings at baseline and 30 days after left ventricular assist device implantation. Overall survival was also compared. Patients undergoing a concomitant tricuspid valve procedure had more tricuspid regurgitation (vena contracta, 5.6 ± 2.1 mm vs 2.9 ± 2.0 mm; P tricuspid regurgitation was worse in patients who underwent left ventricular assist device implantation alone (+18.6%), whereas it improved significantly in patients undergoing a concomitant tricuspid valve procedure (-50.2%) (P = .005). A corresponding significant reduction in right ventricular end-diastolic area (33.6% ± 6.2% vs 30.1% ± 9.7%; P = .03) and a trend toward better right ventricular function (55.5% ± 79.7% vs 35.7% ± 60.5%; P = .28) were noted in patients undergoing a concomitant tricuspid valve procedure. Survival was comparable between the 2 groups. In patients with severe tricuspid regurgitation undergoing left ventricular assist device implantation, a concomitant tricuspid valve procedure effectively reduces tricuspid regurgitation and promotes reverse remodeling of the right ventricle. Copyright © 2012 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.

  7. Postoperative B-Type Natriuretic Peptide as Predictor for Postoperative Outcomes in Patients Implanted With Left Ventricular Assist Devices.

    Science.gov (United States)

    Yost, Gardner; Bhat, Geetha; Pappas, Patroklos; Tatooles, Antone

    2018-04-18

    Brain natriuretic peptide (BNP) is a cardiac neurohormone known to correlate with left ventricular (LV) dilation, decreased contractility, and increased stiffness. Consequently, BNP has been used as a prognostic tool to assess the degree of LV unloading for patients supported by continuous-flow LV assist devices (LVADs). We assessed the prognostic value of changes in BNP in the 2 weeks after LVAD implantation. This retrospective study analyzed laboratory findings and outcomes of 189 LVAD patients. Patients were separated into two groups based on whether serum BNP levels had improved from preoperative levels by postoperative day 14. Group 1 had improvement in BNP levels, whereas group 2 had no improvement or worsening in BNP. There were no significant differences between the groups in age, gender, race, body mass index, or comorbidities. Group 1 had preoperative BNP 1,125 ± 1,078.3 pg/dl and postoperative BNP 440.2 ± 267.7 pg/dl (ΔBNP = -693.09 ± 942.4 pg/dl), whereas group 2 had preoperative BNP 346.0 ± 309.1 pg/dl and postoperative BNP 631.57 ± 483.4 pg/dl (ΔBNP = 289.32 ± 329.7 pg/dl). Postoperative survival in group 2 was significantly worse than in group 1. Rates of right ventricular failure (RVF) were significantly higher in group 2 (group 1: 39%, group 2: 52.7%; p = 0.01). In most patients implanted with a LVAD, BNP improves significantly in the postoperative period as the LV is unloaded. Our results indicate that lack of improvement in postoperative BNP is associated with longer length of stay, increased rates of RVF, and is an independent risk factor for reduced postoperative survival.

  8. A case of delayed cardiac perforation of active ventricular lead

    Directory of Open Access Journals (Sweden)

    Hangyuan Guo

    2011-12-01

    Full Text Available A 65-year-old man was admitted as for one month of repetitive dizziness and one episode of syncope. Electrocardiogram showed sinus bradycardia and his Holter monitoring also showed sinus bradycardia with sinus arrest, sino-atrial block and a longest pause of 4.3 s. Then sick sinus syndrome and Adam-Stokes syndrome were diagnosed. Then a dual chamber pacemaker (Medtronic SDR303 was implanted and the parameters were normal by detection. The patient was discharged 1 week later with suture removed. Then 1.5 month late the patient was presented to hospital once again for sudden onset of chest pain with exacerbation after taking deep breath. Pacemaker programming showed both pacing and sensing abnormality with threshold of?5.0V and resistance of 1200?. Lead perforation was revealed by chest X-ray and confirmed by echocardiogram. Considering the fact that there was high risk to remove ventricular lead, spiral tip of previous ventricular lead was withdrew followed by implantation of a new ventricular active lead to the septum. Previous ventricular lead was maintained. As we know that the complications of lead perforation in the clinic was rare. Here we discuss the clinical management and the possible reasons for cardiac perforation of active ventricular lead.

  9. Left Ventricular Assist Devices

    Directory of Open Access Journals (Sweden)

    Khuansiri Narajeenron

    2017-04-01

    Full Text Available Audience: The audience for this classic team-based learning (cTBL session is emergency medicine residents, faculty, and students; although this topic is applicable to internal medicine and family medicine residents. Introduction: A left ventricular assist device (LVAD is a mechanical circulatory support device that can be placed in critically-ill patients who have poor left ventricular function. After LVAD implantation, patients have improved quality of life.1 The number of LVAD patients worldwide continues to rise. Left-ventricular assist device patients may present to the emergency department (ED with severe, life-threatening conditions. It is essential that emergency physicians have a good understanding of LVADs and their complications. Objectives: Upon completion of this cTBL module, the learner will be able to: 1 Properly assess LVAD patients’ circulatory status; 2 appropriately resuscitate LVAD patients; 3 identify common LVAD complications; 4 evaluate and appropriately manage patients with LVAD malfunctions. Method: The method for this didactic session is cTBL.

  10. A novel implantable electromechanical ventricular assist device - First acute animal testing

    NARCIS (Netherlands)

    Kaufmann, R; Rakhorst, G; Mihaylov, D; Elstrodt, J; Nix, C; Reul, H; Rau, G

    1997-01-01

    A novel ventricular assist device (HIA-EMLVAD-AT1, Helmholtz Institute Aachen-electromechanical Left Ventricular Assist Device-Animal Test Version 1), driven by a uniformly and unidirectionally rotating actuator and a patented hypocycloidic pusherplate displacement gear unit, was developed and

  11. Do implantable cardioverter defibrillators improve survival in patients with severe left ventricular systolic dysfunction after coronary artery bypass graft surgery?

    Science.gov (United States)

    Fazal, Iftikhar A; Bates, Matthew G D; Matthews, Iain G; Turley, Andrew J

    2011-06-01

    A best evidence topic in cardiac surgery was written according to a structured protocol. The question addressed was whether implantable cardioverter defibrillators (ICD) improve survival in patients with severe left ventricular systolic dysfunction (LVSD) after coronary artery bypass graft (CABG) surgery. ICDs are designed to terminate potentially fatal cardiac tachyarrhythmias. A right ventricular lead is mandatory for detection, pacing and defibrillation capabilities. Dual chamber ICDs have an additional right atrial lead and are used for patients with conventional atrioventricular pacing indications. More sophisticated, biventricular devices exist to provide cardiac resynchronisation therapy (CRT) in addition to defibrillation (CRT-D). ICDs have been extensively investigated in patients with LVSD post myocardial infarction and in patients with non-ischaemic cardiomyopathy for both secondary prevention (history of ventricular arrhythmias) and primary prevention (deemed high risk for ventricular arrhythmias). This best evidence topic aims to review the evidence and its applicability to patients post CABG. Nine hundred and sixteen papers were identified using the search method outlined. Eight randomised controlled trials, two meta-analyses, and one non-randomised trial, in addition to international guidelines presented the best evidence to answer the clinical question. The current evidence base and guidelines suggest that ICDs should be considered for all patients with LVSD [ejection fraction (EF) ≤30-40%] receiving optimal pharmacological management, who are ≥40 days post MI [four weeks for National Institute for Health and Clinical Excellence (NICE)] and in New York Heart Association (NYHA) class I-III. UK NICE guidelines require in addition; non-sustained ventricular tachycardia (NSVT) on a Holter monitor and inducible ventricular tachycardia at electrophysiological study for EF between 30 and 35%; or a QRS >120 ms if EF <30%. The North American guidelines

  12. [A totally implantable venous access device. Implantation in general or local anaesthesia? A retrospective cost analysis].

    Science.gov (United States)

    Schuld, J; Richter, S; Moussavian, M R; Kollmar, O; Schilling, M K

    2009-08-01

    Implantation of venous access port systems can be performed in local or general anesthesia. In spite of the increasing rate of interventionally implanted systems, the surgical cut-down represents a safe alternative. Thus, the question arises whether--in context to the increasing health-economic pressure--open implantation in general anesthesia is still a feasible alternative to implantation in local anesthesia regarding OR efficiency and costs. In a retrospective analysis, 993 patients receiving a totally implantable venous access device between 2001 and 2007 were evaluated regarding OR utilization, turnover times, intraoperative data and costs. Implantations in local (LA) and general anesthesia (GA) were compared. GA was performed in 762 cases (76.6 %), LA was performed in 231 patients (23.3 %). Mean operation time was similar in both groups (LA 47.27 +/- 1.40 min vs. GA 45.41 +/- 0.75 min, p = 0.244). Patients receiving local anesthesia had a significantly shorter stay in the OR unit (LA 95.9 +/- 1.78 min vs. GA 105.92 +/- 0.92 min; p cut (LA 39.57 +/- 0.69 min vs. GA 50.46 +/- 0.52 min; p material costs were significantly lower in the LA group compared with the GA group (LA: 400.72 +/- 8.25 euro vs. GA: 482.86 +/- 6.23 euro; p systems in local anesthesia is superior in comparison to the implantation under general anesthesia regarding procedural times in the OR unit and costs. With the same operation duration, but less personnel and material expenditure, implantation in local anesthesia offers a potential economic advantage by permitting faster changing times. Implantation in GA only should be performed at a special request by the patient or in difficult venous conditions. Georg Thieme Verlag Stuttgart.New York.

  13. Intracorporeal Heat Distribution from Fully Implantable Energy Sources for Mechanical Circulatory Support: A Computational Proof-of-Concept Study

    OpenAIRE

    Biasetti, Jacopo; Pustavoitau, Aliaksei; Spazzini, Pier Giorgio

    2017-01-01

    Mechanical circulatory support devices, such as total artificial hearts and left ventricular assist devices, rely on external energy sources for their continuous operation. Clinically approved power supplies rely on percutaneous cables connecting an external energy source to the implanted device with the associated risk of infections. One alternative, investigated in the 70s and 80s, employs a fully implanted nuclear power source. The heat generated by the nuclear decay can be converted into ...

  14. Comparative analysis of von Willebrand factor profiles after implantation of left ventricular assist device and total artificial heart.

    Science.gov (United States)

    Reich, H J; Morgan, J; Arabia, F; Czer, L; Moriguchi, J; Ramzy, D; Esmailian, F; Lam, L; Dunhill, J; Volod, O

    2017-08-01

    Essentials Bleeding is a major source of morbidity during mechanical circulatory support. von Willebrand factor (VWF) multimer loss may contribute to bleeding. Different patterns of VWF multimer loss were seen with the two device types. This is the first report of total artificial heart associated VWF multimer loss. Background Bleeding remains a challenge during mechanical circulatory support and underlying mechanisms are incompletely understood. Functional von Willebrand factor (VWF) impairment because of loss of high-molecular-weight multimers (MWMs) produces acquired von Willebrand disease (VWD) after left ventricular assist device (LVAD). Little is known about VWF multimers with total artificial hearts (TAHs). Here, VWF profiles with LVADs and TAHs are compared using a VWD panel. Methods VWD evaluations for patients with LVAD or TAH (2013-14) were retrospectively analyzed and included: VWF activity (ristocetin cofactor, VWF:RCo), VWF antigen (VWF:Ag), ratio of VWF:RCo to VWF:Ag, and quantitative VWF multimeric analysis. Results Twelve patients with LVADs and 12 with TAHs underwent VWD evaluation. All had either normal (47.8%) or elevated (52.2%) VWF:RCo, normal (26.1%) or elevated (73.9%) VWF:Ag and 50.0% were disproportional (ratio ≤ 0.7). Multimeric analysis showed abnormal patterns in all patients with LVADs: seven with high MWM loss; five with highest MWM loss. With TAH, 10/12 patients had abnormal patterns: all with highest MWM loss. High MWM loss correlated with presence of LVAD and highest MWM loss with TAH. Increased low MWMs were detected in 22/24. Conclusion Using VWF multimeric analysis, abnormalities after LVAD or TAH were detected that would be missed with measurements of VWF level alone: loss of high MWM predominantly in LVAD, loss of highest MWM in TAH, and elevated levels of low MWM in both. This is the first study to describe TAH-associated highest MWM loss, which may contribute to bleeding. © 2017 International Society on Thrombosis and

  15. Implante transcateter de valva aórtica: resultados atuais do desenvolvimento e implante de um nova prótese brasileira Transcatheter aortic valve implantation: results of the current development and implantation of a new Brazilian prosthesis

    Directory of Open Access Journals (Sweden)

    Diego Felipe Gaia

    2011-09-01

    Full Text Available OBJETIVO: A troca valvar aórtica é procedimento rotineiro com risco aceitável. Em alguns casos, a mortalidade é elevada, contraindicando o procedimento. O implante minimamente invasivo transcateter de valva aórtica parece ser alternativa, reduzindo a morbimortalidade. A avaliação dos resultados clínicos, segurança e eficácia do procedimento são o objetivo desse estudo. MÉTODOS: Uma prótese transcateter, balão expansível foi utilizada em 33 casos de alto risco. EuroScore médio foi de 39,30% e STS score de 30,28%. Oito pacientes apresentavam disfunção de bioprótese e o restante, estenose aórtica calcificada. Os procedimentos foram realizados em ambiente cirúrgico híbrido, sob controle ecocardiográfico e fluoroscópico. Através de minitoracotomia esquerda, as próteses foram implantadas pelo ápice ventricular, sob estimulação de alta frequência ou choque hemorrágico. Foram realizados controles clínicos e ecocardiográficos. RESULTADOS: A correta liberação da prótese foi possível em 30 casos. Três conversões ocorreram. A mortalidade operatória foi de um caso e a mortalidade em 30 dias, 18,18%. O gradiente médio reduziu de 43,58 para 10,54 mmHg. A fração de ejeção apresentou aumento significativo após o 7º pós-operatório. Insuficiência aórtica residual esteve presente em 30,30% dos pacientes. Ocorreu uma complicação vascular periférica e um caso de bloqueio atrioventricular total. Um paciente apresentou acidente vascular cerebral. A mortalidade em 30 dias foi de 18,18%. CONCLUSÃO: O implante transapical de valva aórtica transcateter é procedimento seguro e com resultados de médio prazo satisfatórios. São necessários estudos de longo prazo com maior poder amostral no intuito de determinar resultado hemodinâmico, qualidade de vida e sobrevida em longo prazoOBJECTIVE: Aortic valve replacement is a routine procedure with acceptable risk, but in some cases, such risk can justify contraindication

  16. The natural history of new-onset heart failure with a severely depressed left ventricular ejection fraction: implications for timing of implantable cardioverter-defibrillator implantation.

    Science.gov (United States)

    Teeter, William A; Thibodeau, Jennifer T; Rao, Krishnasree; Brickner, M Elizabeth; Toto, Kathleen H; Nelson, Lauren L; Mishkin, Joseph D; Ayers, Colby R; Miller, Justin G; Mammen, Pradeep P A; Patel, Parag C; Markham, David W; Drazner, Mark H

    2012-09-01

    Guidelines recommend that patients with new-onset systolic heart failure (HF) receive a trial of medical therapy before an implantable cardiac defibrillator (ICD). This strategy allows for improvement of left ventricular ejection fraction (LVEF), thereby avoiding an ICD, but exposes patients to risk of potentially preventable sudden cardiac death during the trial of medical therapy. We reviewed a consecutive series of patients with HF of <6 months duration with a severely depressed LVEF (<30%) evaluated in a HF clinic (N = 224). The ICD implantation was delayed with plans to reassess LVEF approximately 6 months after optimization of β-blockers. Mortality was ascertained by the National Death Index. Follow-up echocardiograms were performed in 115 of the 224 subjects. Of these, 50 (43%) had mildly depressed or normal LVEF at follow-up ("LVEF recovery") such that an ICD was no longer indicated. In a conservative sensitivity analysis (using the entire study cohort, whether or not a follow-up echocardiogram was obtained, as the denominator), 22% of subjects had LVEF recovery. Mortality at 6, 12, and 18 months in the entire cohort was 2.3%, 4.5%, and 6.8%, respectively. Of 87 patients who tolerated target doses of β-blockers, only 1 (1.1%) died during the first 18 months. Patients with new-onset systolic HF have both a good chance of LVEF recovery and low 6-month mortality. Achievement of target β-blocker dose identifies a very low-risk population. These data support delaying ICD implantation for a trial of medical therapy. Copyright © 2012 Mosby, Inc. All rights reserved.

  17. Ventricular tachyarrhythmias and mortality in patients with an implantable cardioverter defibrillator: impact of depression in the MIDAS cohort.

    Science.gov (United States)

    Mastenbroek, Mirjam H; Versteeg, Henneke; Jordaens, Luc; Theuns, Dominic A M J; Pedersen, Susanne S

    2014-01-01

    We examined whether depression is independently associated with implantable cardioverter defibrillator (ICD) therapy for ventricular tachyarrhythmias and mortality. A cohort of 430 consecutive patients with a first-time ICD (79% men; mean [standard deviation] age = 57.8 [12.1] years) completed the Hospital Anxiety and Depression Scale 1 day before implantation. During follow-up, the ICD was interrogated at 3-month intervals. Cox proportional hazard regression analyses were used to examine the impact of depression on time to first appropriate ICD therapy and all-cause mortality during a median follow-up period of 3.8 years. Of all patients, 108 (25.1%) were depressed. Depression was not associated with time to first appropriate ICD therapy (unadjusted hazard ratio [HR] = 1.07, 95% confidence interval [CI] = 0.73-1.56). However, depression was associated with an increased risk for all-cause mortality (unadjusted HR = 2.18, 95% CI = 1.36-3.49). Depression remained independently associated with all-cause mortality (HR = 1.94, 95% CI = 1.06-3.54, p = .031), after adjusting for demographic and clinical characteristics. Patients who remained depressed during the first 3 months after implantation were at greatest risk for dying (HR = 2.88, 95% CI = 1.29-6.45, p = .010). The current study showed that depression at the time of implant is not associated with time to first appropriate ICD therapy but almost doubled the risk for all-cause mortality in patients with an ICD. Patients with persistent depression during the first 3 months after implantation face the greatest risk of dying. Current evidence indicates that multifactorial interventions are likely to be the most successful in terms of reducing distress. Whether this translates into enhanced survival has yet to be determined.

  18. Percutaneous Trans-hepatic Obliteration for Bleeding Esophagojejunal Varices After Total Gastrectomy and Esophagojejunostomy

    International Nuclear Information System (INIS)

    Boku, Michiko; Sugimoto, Koji; Nakamura, Tetsu; Kita, Yasufumi; Zamora, Carlos A.; Sugimura, Kazuro

    2006-01-01

    A 72-year-old man who had undergone a total gastrectomy with a Roux-en-Y esophagojejunostomy for gastric cancer 6 years earlier presented to our hospital with massive hematemesis and melena. Endoscopic examination indicated esophageal varices with cherry-red spots and hemorrhage arising from beyond the anastomosis. Abdominal contrast-enhanced computed tomography and angiography revealed a dilated vein in the elevated jejunal limb supplying the varices. Percutaneous trans-hepatic obliteration (PTO) of the varices through the jejunal vein was performed using microcoils, ethanolamine oleate, and gelatin sponge cubes. Ten days after the procedure, endoscopic examination revealed reduction and thrombosis of the varices. We consider PTO to be an effective alternative method for treating ruptured esophagojejunal varices after total gastrectomy

  19. Atrioventricular and ventricular-to-ventricular programming in patients with cardiac resynchronization therapy: results from ALTITUDE.

    Science.gov (United States)

    Steinberg, Benjamin A; Wehrenberg, Scott; Jackson, Kevin P; Hayes, David L; Varma, Niraj; Powell, Brian D; Day, John D; Frazier-Mills, Camille G; Stein, Kenneth M; Jones, Paul W; Piccini, Jonathan P

    2015-12-01

    Cardiac resynchronization therapy (CRT) improves outcomes in patients with heart failure, yet response rates are variable. We sought to determine whether physician-specified CRT programming was associated with improved outcomes. Using data from the ALTITUDE remote follow-up cohort, we examined sensed atrioventricular (AV) and ventricular-to-ventricular (VV) programming and their associated outcomes in patients with de novo CRT from 2009-2010. Outcomes included arrhythmia burden, left ventricular (LV) pacing, and all-cause mortality at 4 years. We identified 5709 patients with de novo CRT devices; at the time of implant, 34% (n = 1959) had entirely nominal settings programmed, 40% (n = 2294) had only AV timing adjusted, 11% (n = 604) had only VV timing adjusted, and 15% (n = 852) had both AV and VV adjusted from nominal programming. Suboptimal LV pacing (5% was lowest in the AV-only adjusted group (17.9%) and highest in the nominal (27.7%) and VV-only adjusted (28.3%) groups. Adjusted all-cause mortality was significantly higher among patients with non-nominal AV delay >120 vs. 180 vs. ≤180 ms, p = 0.4). Nominal settings for de novo CRT implants are frequently altered, most commonly the AV delay. There is wide variability in reprogramming. Patients with nominal or AV-only adjustments appear to have favorable pacing and arrhythmia outcomes. Sensed AV delays less than 120 ms are associated with improved survival.

  20. Total dose hardening of buried insulator in implanted silicon-on-insulator structures

    International Nuclear Information System (INIS)

    Mao, B.Y.; Chen, C.E.; Pollack, G.; Hughes, H.L.; Davis, G.E.

    1987-01-01

    Total dose characteristics of the buried insulator in implanted silicon-on-insulator (SOI) substrates have been studied using MOS transistors. The threshold voltage shift of the parasitic back channel transistor, which is controlled by charge trapping in the buried insulator, is reduced by lowering the oxygen dose as well as by an additional nitrogen implant, without degrading the front channel transistor characteristics. The improvements in the radiation characteristics of the buried insulator are attributed to the decrease in the buried oxide thickness or to the presence of the interfacial oxynitride layer formed by the oxygen and nitrogen implants

  1. Changes in Speckle Tracking Echocardiography Measures of Ventricular Function after Percutaneous Implantation of the Edwards SAPIEN Transcatheter Heart Valve in the Pulmonary Position

    Science.gov (United States)

    Chowdhury, Shahryar M.; Hijazi, Ziyad M.; Rhodes, John F.; Kar, Saibal; Makkar, Raj; Mullen, Michael; Cao, Qi-Ling; Mandinov, Lazar; Buckley, Jason; Pietris, Nicholas P.; Shirali, Girish S.

    2015-01-01

    Background Patients with free pulmonary regurgitation or mixed pulmonary stenosis and regurgitation and severely dilated right ventricles (RV) show little improvement in ventricular function after pulmonary valve replacement when assessed by traditional echocardiographic markers. We evaluated changes in right and left ventricular (LV) function using speckle tracking echocardiography in patients after SAPIEN transcatheter pulmonary valve (TPV) placement. Methods Echocardiograms were evaluated at baseline, discharge, 1 and 6 months after TPV placement in 24 patients from 4 centers. Speckle tracking measures of function included peak longitudinal strain, strain rate, and early diastolic strain rate. RV fractional area change, tricuspid annular plane systolic excursion, and left ventricular LV ejection fraction were assessed. Routine Doppler and tissue Doppler velocities were measured. Results At baseline, all patients demonstrated moderate to severe pulmonary regurgitation; this improved following TPV placement. No significant changes were detected in conventional measures of RV or LV function at 6 months. RV longitudinal strain (−16.9% vs. −19.6%, P echocardiography may be more sensitive than traditional measures in detecting changes in systolic function after TPV implantation. (Echocardiography 2015;32:461–469) PMID:25047063

  2. Costs and reimbursement gaps after implementation of third-generation left ventricular assist devices.

    Science.gov (United States)

    Mishra, Vinod; Geiran, Odd; Fiane, Arnt E; Sørensen, Gro; Andresen, Sølvi; Olsen, Ellen K; Khushi, Ishtiaq; Hagen, Terje P

    2010-01-01

    The purpose of this study was to compare and contrast total hospital costs and subsequent reimbursement of implementing a new program using a third-generation left ventricular assist device (LVAD) in Norway. Between July 2005 and March 2008, the total costs of treatment for 9 patients were examined. Costs were calculated for three periods-the pre-implantation LVAD phase, the LVAD implantation phase and the post-implantation LVAD phase-as well as for total hospital care. Patient-specific costs were obtained prospectively from patient records and included personnel resources, medication, blood products, blood chemistry and microbiology, imaging, and procedure costs including operating room costs. Overhead costs were registered retrospectively and allocated to the specific patient by pre-defined allocation keys. Finally, patient-specific costs and overhead costs were aggregated into total patient costs. The average total patient cost in 2007 U.S. dollars was $735,342 and the median was $613,087 (range $342,581 to $1,256,026). The mean length of stay was 77 days (range 40 to 127 days). For the LVAD implantation phase, the mean cost was $457,795 and median cost was $458,611 (range $246,239 to $677,680). The mean length of stay for the LVAD implantation phase was 55 days (range 25 to 125 days). The diagnosis-related group (DRG) reimbursement (2007) was $143,192. There is significant discrepancy between actual hospital costs and the current Norwegian DRG reimbursement for the LVAD procedure. This discrepancy can be partly explained by excessive costs related to the introduction of a new program with new technology. Costly innovations should be considered in price setting of reimbursement for novel technology. Copyright (c) 2010 International Society for Heart and Lung Transplantation. Published by Elsevier Inc. All rights reserved.

  3. Hollow mandrin facilitates external ventricular drainage placement.

    Science.gov (United States)

    Heese, O; Regelsberger, J; Kehler, U; Westphal, M

    2005-07-01

    Placement of ventricular catheters is a routine procedure in neurosurgery. Ventricle puncture is done using a flexible ventricular catheter stabilised by a solid steel mandrin in order to improve stability during brain penetration. A correct catheter placement is confirmed after removing the solid steel mandrin by observation of cerebrospinal fluid (CSF) flow out of the flexible catheter. Incorrect placement makes further punctures necessary. The newly developed device allows CSF flow observation during the puncture procedure and in addition precise intracranial pressure (ICP) measurement. The developed mandrin is hollow with a blunt tip. On one side 4-5 small holes with a diameter of 0.8 mm are drilled corresponding exactly with the holes in the ventricular catheter, allowing CSF to pass into the hollow mandrin as soon as the ventricle is reached. By connecting a small translucent tube at the distal portion of the hollow mandrin ICP can be measured without loss of CSF. The system has been used in 15 patients with subarachnoid haemorrhage (SAH) or intraventricular haemeorrhage (IVH) and subsequent hydrocephalus. The new system improved the external ventricular drainage implantation procedure. In all 15 patients catheter placement was correct. ICP measurement was easy to perform immediately at ventricle puncture. In 4 patients at puncture no spontaneous CSF flow was observed, therefore by connecting a syringe and gentle aspiration of CSF correct placement was confirmed in this unexpected low pressure hydrocephalus. Otherwise by using the conventional technique further punctures would have been necessary. Advantages of the new technique are less puncture procedures with a lower risk of damage to neural structures and reduced risk of intracranial haemorrhages. Implantation of the ventricular catheter to far into the brain can be monitored and this complication can be overcome. Using the connected pressure monitoring tube an exact measurement of the opening

  4. Sub-meninges implantation reduces immune response to neural implants.

    Science.gov (United States)

    Markwardt, Neil T; Stokol, Jodi; Rennaker, Robert L

    2013-04-15

    Glial scar formation around neural interfaces inhibits their ability to acquire usable signals from the surrounding neurons. To improve neural recording performance, the inflammatory response and glial scarring must be minimized. Previous work has indicated that meningeally derived cells participate in the immune response, and it is possible that the meninges may grow down around the shank of a neural implant, contributing to the formation of the glial scar. This study examines whether the glial scar can be reduced by placing a neural probe completely below the meninges. Rats were implanted with sets of loose microwire implants placed either completely below the meninges or implanted conventionally with the upper end penetrating the meninges, but not attached to the skull. Histological analysis was performed 4 weeks following surgical implantation to evaluate the glial scar. Our results found that sub-meninges implants showed an average reduction in reactive astrocyte activity of 63% compared to trans-meninges implants. Microglial activity was also reduced for sub-meninges implants. These results suggest that techniques that isolate implants from the meninges offer the potential to reduce the encapsulation response which should improve chronic recording quality and stability. Published by Elsevier B.V.

  5. A case of appropriate inappropriate device therapy: Hyperkalemia-induced ventricular oversensing

    Science.gov (United States)

    Oudit, Gavin Y; Cameron, Doug; Harris, Louise

    2008-01-01

    The present case describes a patient who received inappropriate, but potentially life-saving, therapy from her implantable cardioverter defibrillator (ICD) in the setting of acute hyperkalemia (plasma potassium concentration = 8 mM). Hyperkalemia was associated with the development of a slow sinusoidal ventricular tachycardia, at a rate of 100 beats/min to 125 beats/min (610 ms to 480 ms) in a patient who is pacemaker-dependent. There was associated fractionation of the ICD electrogram and T wave oversensing, leading to ventricular oversensing with resultant detection in the ventricular fibrillation rate zone. This was followed by shock therapy, even though the ventricular tachycardia rate was below the programmed detection rate of the ICD. The subsequent emergency treatment of the hyperkalemia normalized the electrogram, corrected the ventricular oversensing and arrhythmia, and restored rate-adaptive single-chamber ventricular pacing. PMID:18340383

  6. Prognostic value of tissue Doppler imaging for predicting ventricular arrhythmias and cardiovascular mortality in ischaemic cardiomyopathy

    DEFF Research Database (Denmark)

    Biering-Sørensen, Tor; Olsen, Flemming Javier; Storm, Katrine

    2016-01-01

    AIMS: Only 30% of patients receiving an implantable cardioverter defibrillator (ICD) for primary prevention receive appropriately therapy. We sought to investigate the value of tissue Doppler imaging (TDI) to predict ventricular tachycardia (VT), ventricular fibrillation (VF), and cardiovascular...

  7. Machines versus medication for biventricular heart failure: focus on the total artificial heart.

    Science.gov (United States)

    Arabia, Francisco A; Moriguchi, Jaime D

    2014-09-01

    The medical/surgical management of advanced heart failure has evolved rapidly over the last few decades. With better understanding of heart failure pathophysiology, new pharmacological agents have been introduced that have resulted in improvements in survival. For those patients that fail to improve, mechanical circulatory support with left ventricular assist devices and total artificial hearts (TAHs) have served as a beneficial bridge to transplantation. The TAH has continued to play a significant role as a bridge to transplantation in patients with biventricular failure and more selected indications that could not be completely helped with left ventricular assist devices. Improved survival with the TAH has resulted in more patients benefiting from this technology. Improvements will eventually lead to a totally implantable device that will permanently replace the failing human heart.

  8. The total artificial heart.

    Science.gov (United States)

    Cook, Jason A; Shah, Keyur B; Quader, Mohammed A; Cooke, Richard H; Kasirajan, Vigneshwar; Rao, Kris K; Smallfield, Melissa C; Tchoukina, Inna; Tang, Daniel G

    2015-12-01

    The total artificial heart (TAH) is a form of mechanical circulatory support in which the patient's native ventricles and valves are explanted and replaced by a pneumatically powered artificial heart. Currently, the TAH is approved for use in end-stage biventricular heart failure as a bridge to heart transplantation. However, with an increasing global burden of cardiovascular disease and congestive heart failure, the number of patients with end-stage heart failure awaiting heart transplantation now far exceeds the number of available hearts. As a result, the use of mechanical circulatory support, including the TAH and left ventricular assist device (LVAD), is growing exponentially. The LVAD is already widely used as destination therapy, and destination therapy for the TAH is under investigation. While most patients requiring mechanical circulatory support are effectively treated with LVADs, there is a subset of patients with concurrent right ventricular failure or major structural barriers to LVAD placement in whom TAH may be more appropriate. The history, indications, surgical implantation, post device management, outcomes, complications, and future direction of the TAH are discussed in this review.

  9. [Electrical storm in patients with prophylactic defibrillator implantation].

    Science.gov (United States)

    Rodríguez-Mañero, Moisés; González-Cambeiro, Cristina; Moreno-Arribas, Jose; Expósito-García, Víctor; Sánchez-Gómez, Juan Miguel; González-Torres, Luis; Arce-León, Álvaro; Arguedas-Jiménez, Hugo; Gaztañaga, Larraitz; Salvador-Montañés, Oscar; Iglesias-Bravo, Jose Antonio; Huerta, Ana Andrés La; Fernández-Armenta, Juan; Arias, Miguel Ángel; Martínez-Sande, Luis

    2016-01-01

    Little is known about the prevalence of electrical storm, baseline characteristics and mortality implications of patients with implantable cardioverter defibrillator in primary prevention versus those patients without electrical storm. We sought to assess the prevalence, baseline risk profile and survival significance of electrical storm in patients with implantable defibrillator for primary prevention. Retrospective multicenter study performed in 15 Spanish hospitals. Consecutives patients referred for desfibrillator implantation, with or without left ventricular lead (at least those performed in 2010 and 2011), were included. Over all 1,174 patients, 34 (2,9%) presented an electrical storm, mainly due to ventricular tachycardia (82.4%). There were no significant baseline differences between groups, with similar punctuation in the mortality risk scores (SHOCKED, MADIT and FADES). A clear trigger was identified in 47% of the events. During the study period (38±21 months), long-term total mortality (58.8% versus 14.4%, pstorm patients. Rate of inappropriate desfibrillator intervention was also higher (14.7 versus 8.6%, pstorm was 2.9%. There were no baseline differences in the cardiovascular risk profile versus those without electrical storm. However, all cause mortality and cardiovascular mortality was increased in these patients versus control desfibrillator patients without electrical storm, as was the rate of inappropriate desfibrillator intervention. Copyright © 2015 Instituto Nacional de Cardiología Ignacio Chávez. Published by Masson Doyma México S.A. All rights reserved.

  10. Importance of beta-blocker dose in prevention of ventricular tachyarrhythmias, heart failure hospitalizations, and death in primary prevention implantable cardioverter-defibrillator recipients

    DEFF Research Database (Denmark)

    Ruwald, A C; Gislason, G H; Vinther, M

    2018-01-01

    Aims: There is a paucity of studies investigating a dose-dependent association between beta-blocker therapy and risk of outcome. In a nationwide cohort of primary prevention implantable cardioverter-defibrillator (ICD) patients, we aimed to investigate the dose-dependent association between beta-blocker...... therapy and risk of ventricular tachyarrhythmias (VT/VF), heart failure (HF) hospitalizations, and death. Methods and results: Information on ICD implantation, endpoints, comorbidities, beta-blocker usage, type, and dose were obtained through Danish nationwide registers. The two major beta-blockers...... carvedilol and metoprolol were examined in three dose levels; low (metoprolol ≤ 25 mg; carvedilol ≤ 12.5 mg), intermediate (metoprolol 26-199 mg; carvedilol 12.6-49.9 mg), and high (metoprolol ≥ 200 mg; carvedilol ≥ 50 mg). Time to events was investigated utilizing multivariate Cox models with beta-blocker...

  11. Ischemic Stroke with Cardiac Pacemaker Implantation: Comparison of Physiological and Ventricular Pacing Modes.

    Science.gov (United States)

    Kato, Yuji; Hayashi, Takeshi; Kato, Ritsushi; Tanahashi, Norio; Takao, Masaki

    2017-09-01

    The clinical characteristics of ischemic stroke in patients with a pacemaker (PM) are not well understood. Forty-six ischemic stroke patients with a PM were investigated retrospectively, and the impact of different pacing modes was compared. The patients were divided into a physiological pacing group (n = 22) and a ventricular pacing group (n = 24). The prevalence of atrial fibrillation (AF) was significantly higher in the ventricular pacing group (36% versus 75%; P = .008). The mean left atrial dimension was relatively large in the ventricular pacing group than in the physiological pacing group (44.5 ± 6.7 mm versus 39.1 ± 8.5 mm, respectively; P = .071). Twenty-four percent of the patients were receiving anticoagulants, whereas 41% of the patients were receiving antiplatelet drugs. Cardioembolism was the most common stroke subtype in both groups. Although there was no statistically significant difference, neurological severity on admission was higher in the ventricular pacing group than in the physiological pacing group (P = .061). Functional outcomes, excluding patients with transient ischemic attack or prior stroke, significantly declined in the ventricular pacing group compared with the physiological pacing group (P = .044). The avoidance of the ventricular pacing mode may result in improved clinical outcomes. In patients without persistent AF, it may be important to select physiological pacing instead of ventricular pacing to decrease potential stroke severity. Copyright © 2017 National Stroke Association. Published by Elsevier Inc. All rights reserved.

  12. Management of Implantable Cardioverter Defibrillator Recipients: Care Beyond Guidelines.

    Science.gov (United States)

    Philippon, François; Sterns, Laurence D; Nery, Pablo B; Parkash, Ratika; Birnie, David; Rinne, Claus; Mondesert, Blandine; Exner, Derek; Bennett, Matthew

    2017-08-01

    This companion article is intended to address common clinical scenarios in patients with implantable defibrillators that were not addressed in the 2016 Canadian Cardiovascular Society/Canadian Heart Rhythm Society implantable cardioverter defibrillator guidelines including recommendations for device programming to improve detection, to minimize shocks (appropriate and inappropriate), and to minimize ventricular pacing. Important issues at the time of replacement such as device prescription, technical aspects (vascular access, extraction), and management of components on advisories are also discussed. Finally, common clinical scenarios such as management of patients with terminal illnesses, recurrent ventricular tachycardia, electrical storms, catheter ablation for ventricular tachycardia, and system infection management are considered. The management of these patients requires a team approach and comprehensive knowledge surrounding these common clinical scenarios. Copyright © 2017 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.

  13. Accuracy of Implant Placement Utilizing Customized Patient Instrumentation in Total Knee Arthroplasty

    Directory of Open Access Journals (Sweden)

    William D. Bugbee

    2013-01-01

    Full Text Available Customized patient instrumentation (CPI combines preoperative planning with customized cutting jigs to position and align implants during total knee arthroplasty (TKA. We compared postoperative implant alignment of patients undergoing surgery with CPI to traditional TKA instrumentation for accuracy of implant placement. Twenty-five consecutive TKAs using CPI were analyzed. Preoperative CT scans of the lower extremities were segmented using a computer program. Limb alignment and mechanical axis were computed. Virtual implantation of computer-aided design models was done. Postoperative coronal and sagittal view radiographs were obtained. Using 3D image-matching software, relative positions of femoral and tibial implants were determined. Twenty-five TKAs implanted using traditional instrumentation were also analyzed. For CPI, difference in alignment from the preoperative plan was calculated. In the CPI group, the mean absolute difference between the planned and actual femoral placements was 0.67° in the coronal plane and 1.2° in the sagittal plane. For tibial alignment, the mean absolute difference was 0.9° in the coronal plane and 1.3° in the sagittal plane. For traditional instrumentation, difference from ideal placement for the femur was 1.5° in the coronal plane and 2.3° in the sagittal plane. For the tibia, the difference was 1.8° in the coronal plane. CPI achieved accurate implant positioning and was superior to traditional TKA instrumentation.

  14. Is right ventricular mid-septal pacing superior to apical pacing in patients with high degree atrio-ventricular block and moderately depressed left ventricular function?

    Science.gov (United States)

    Chen, Kang; Mao, Ye; Liu, Shao-hua; Wu, Qiong; Luo, Qing-zhi; Pan, Wen-qi; Jin, Qi; Zhang, Ning; Ling, Tian-you; Chen, Ying; Gu, Gang; Shen, Wei-feng; Wu, Li-qun

    2014-06-01

    We are aimed to investigate whether right ventricular mid-septal pacing (RVMSP) is superior to conventional right ventricular apical pacing (RVAP) in improving clinical functional capacity and left ventricular ejection fraction (LVEF) for patients with high-degree atrio-ventricular block and moderately depressed left ventricle (LV) function. Ninety-two patients with high-degree atrio-ventricular block and moderately reduced LVEF (ranging from 35% to 50%) were randomly allocated to RVMSP (n=45) and RVAP (n=47). New York Heart Association (NYHA) functional class, echocardiographic LVEF, and distance during a 6-min walk test (6MWT) were determined at 18 months after pacemaker implantation. Serum levels of N-terminal pro-brain natriuretic peptide (NT-proBNP) were measured using an enzyme-linked immunosorbent assay (ELISA) kit. Compared with baseline, NYHA functional class remained unchanged at 18 months, distance during 6MWT (485 m vs. 517 m) and LVEF (36.7% vs. 41.8%) were increased, but BNP levels were reduced (2352 pg/ml vs. 710 pg/ml) in the RVMSP group compared with those in the RVAP group, especially in patients with LVEF 35%-40% (for all comparisons, Pfunction capacity and LV function measurements were not significantly changed in patients with RVAP, despite the pacing measurements being similar in both groups, such as R-wave amplitude and capture threshold. RVMSP provides a better clinical utility, compared with RVAP, in patients with high-degree atrioventricular block and moderately depressed LV function whose LVEF levels ranged from 35% to 40%.

  15. Is there a correlation between operative results and change in ventricular volume after shunt placement? A study of 60 cases of idiopathic normal-pressure hydrocephalus

    Energy Technology Data Exchange (ETDEWEB)

    Meier, U.; Graewe, A.; Hajdukova, A. [Department of Neurosurgery, Unfallkrankenhaus Berlin, Warener Strasse 7, 12683, Berlin (Germany); Paris, S.; Stockheim, D.; Mutze, S. [Department of Radiology, Unfallkrankenhaus Berlin, Warener Strasse 7, 12683, Berlin (Germany)

    2003-06-01

    In patients with communicating or normal-pressure hydrocephalus, ventricular volume decreases following implantation of differential pressure valves. We implanted hydrostatic (Miethke dual-switch) valves in 60 patients with normal-pressure hydrocephalus (NPH) between September 1997 and December 2001. The patients underwent CT 1 year after operation, and we measured the Evans index. Although 83% of the patients showed no change in ventricular volume as assessed by this index, 72% nevertheless showed good to excellent and 16% satisfactory clinical improvement, while 12% showed no improvement. Moderate or marked reduction in ventricular size was observed in 17%, of whom 40% of these patients showed good to excellent and 20% satisfactory clinical improvement; 40% showed unsatisfactory improvement. The favourable outcome following implantation of a hydrostatic shunt thus did not correlate with decreased ventricular volume 1 year after operation, better outcomes being observed in patients with little or no alteration in ventricular size than in those with a marked decrease. Postoperative change in ventricular volume in NPH thus does not have the same significance as in patients with high-pressure hydrocephalus. (orig.)

  16. Is there a correlation between operative results and change in ventricular volume after shunt placement? A study of 60 cases of idiopathic normal-pressure hydrocephalus

    International Nuclear Information System (INIS)

    Meier, U.; Graewe, A.; Hajdukova, A.; Paris, S.; Stockheim, D.; Mutze, S.

    2003-01-01

    In patients with communicating or normal-pressure hydrocephalus, ventricular volume decreases following implantation of differential pressure valves. We implanted hydrostatic (Miethke dual-switch) valves in 60 patients with normal-pressure hydrocephalus (NPH) between September 1997 and December 2001. The patients underwent CT 1 year after operation, and we measured the Evans index. Although 83% of the patients showed no change in ventricular volume as assessed by this index, 72% nevertheless showed good to excellent and 16% satisfactory clinical improvement, while 12% showed no improvement. Moderate or marked reduction in ventricular size was observed in 17%, of whom 40% of these patients showed good to excellent and 20% satisfactory clinical improvement; 40% showed unsatisfactory improvement. The favourable outcome following implantation of a hydrostatic shunt thus did not correlate with decreased ventricular volume 1 year after operation, better outcomes being observed in patients with little or no alteration in ventricular size than in those with a marked decrease. Postoperative change in ventricular volume in NPH thus does not have the same significance as in patients with high-pressure hydrocephalus. (orig.)

  17. Improvement of Left Ventricular Function by Permanent Direct His-Bundle Pacing in a Case with Dilated Cardiomyopathy

    Directory of Open Access Journals (Sweden)

    Yukiko Sashida, MD

    2006-01-01

    Full Text Available The patient was a 67-year-old female diagnosed with dilated cardiomyopathy. She had chronic atrial fibrillation (AF with bradycardia and low left ventricular function (left ventricular ejection fraction (LVEF 40%. She was admitted for congestive heart failure. She remained New York Heart Association (NYHA functional class III due to AF bradycardia. Pacemaker implantation was necessary for treatment of heart failure and administration of dose intensive β-blockers. As she had normal His-Purkinje activation, we examined the optimal pacing sites. Hemodynamics of His-bundle pacing and biventricular pacing were compared. Pulmonary capillary wedge pressure (PCWP was significantly lower on Hisbundle pacing than right ventricular (RV apical pacing and biventricular pacing (13mmHg, 19mmHg, and 19mmHg, respectively with an almost equal cardiac index. Based on the examination we implanted a permanent pacemaker for Direct His-bundle pacing (DHBP. After the DHBP implantation, the LVEF immediately improved from 40% to 55%, and BNP level decreased from 422 pg/ml to 42 pg/ml. The number of premature ventricular complex (PVC was decreased, and non sustained ventricular tachycardia (NSVT disappeared. Pacing threshold for His-bundle pacing has remained at the same level. His-bundle pacing has been maintained during 27 months and her long-term DHBP can improve cardiac function and the NYHA functional class.

  18. Repair of the myocardium infarct, with intracoronary implant of mother cells (stem cells) precocious improvement of the ventricular function and the ischemy (first reports of the TECELCOR report)

    International Nuclear Information System (INIS)

    Fernandez Vina, Roberto; Vrsalovic, Francisco; Andrin, Oberdan and others

    2004-01-01

    Twenty patients who suffered extensive anterior myocardial infarction with an evolution of 5 to 72 hours were submitted to a primary PTCA with Stent. The ventricular ejection fraction oscillated between 21 to 30% in correlation to the bidimensional echocardiography. Between the 7th and 12th day, mononuclear CD 34(+) and CD 38(-) cells extracted from the patient's bone marrow were implanted through the anterior descendent coronary artery, with occlusion of the anterior coronary vein, in an average amount of 22 x 10 P6. echocardiographic controls were performed each 7 days until 60 days, noticing a progressive increment in the ejection fraction (EF) from 25 to 45% in the first 60 days, and an improvement of the EF up to 80% after 90 days. Between 90 and 120 days after, a coronary ventriculography was performed, and the permeability of all the implanted stents and an improvement of the EF up to 80% with respect to the basal EF, were observed. The Spect studies were negative with negative ergonometry at 700 kgm. This group of patients was comparing red with 16 patients who were submitted only to primary PTCA with Stent. They had an increase of only 45% of the EF respect to the basal one in the next 90 days and 12 % presented restenosis. Stems cells implant improves the left ventricular performance after a myocardial infarction and it seems to avoid the coronary post-restenosis

  19. Assessment of Safety and Effectiveness of the Extracorporeal Continuous-Flow Ventricular Assist Device (BR16010) Use as a Bridge-to-Decision Therapy for Severe Heart Failure or Refractory Cardiogenic Shock: Study Protocol for Single-Arm Non-randomized, Uncontrolled, and Investigator-Initiated Clinical Trial.

    Science.gov (United States)

    Fukushima, Norihide; Tatsumi, Eisuke; Seguchi, Osamu; Takewa, Yoshiaki; Hamasaki, Toshimitsu; Onda, Kaori; Yamamoto, Haruko; Hayashi, Teruyuki; Fujita, Tomoyuki; Kobayashi, Junjiro

    2018-06-08

    The management of heart failure patients presenting in a moribund state remains challenging, despite significant advances in the field of ventricular assist systems. Bridge to decision involves using temporary devices to stabilize the hemodynamic state of such patients while further assessment is performed and a decision can be made regarding patient management. The purpose of this study (NCVC-BTD_01, National Cerebral and Cardiovascular Center-Bridge to Dicision_01) is to assess the safety and effectiveness of the newly developed extracorporeal continuous-flow ventricular assist system employing a disposable centrifugal pump with a hydrodynamically levitated bearing (BR16010) use as a bridge-to-decision therapy for patients with severe heart failure or refractory cardiogenic shock. NCVC-BTD_01 is a single-center, single-arm, open-label, exploratory, medical device, investigator-initiated clinical study. It is conducted at the National Cerebral and Cardiovascular Center in Japan. A total of nine patients will be enrolled in the study. The study was planned using Simon's minimax two-stage phase design. The primary endpoint is a composite of survival free of device-related serious adverse events and complications during device support. For left ventricular assistance, withdrawal of a trial device due to cardiac function recovery or exchange to other ventricular assist devices (VADs) for the purpose of bridge to transplantation (BTT) during 30 days after implantation will be considered study successes. For right ventricular assistance, withdrawal of tal device due to right ventricular function recovery within 30 days after implantation will be considered a study success. Secondary objectives include changes in brain natriuretic peptide levels (7 days after implantation of a trial device and the day of withdrawal of a trial device), period of mechanical ventricular support, changes in left ventricular ejection fraction (7 days after implantation of a trial device

  20. The Effect of Preoperative Cognitive Behavior and Exercise Therapy for a Patient With an Implanted Left Ventricular Assist Device in Korea.

    Science.gov (United States)

    Seo, Yong Gon; Park, Won Hah; Jeon, Eun Seok; Sung, Ji Dong; Jang, Mi Ja

    2017-10-01

    Left ventricular assist devices (LVADs) are used in patients with progressive heart failure symptoms to provide circulatory support. Patients with LVADs are referred to inpatient cardiac rehabilitation to prevent postoperative complications and improve aerobic capacity and quality of life. Preoperative exercise therapy for cardiac patients is an emerging treatment modality, and several studies have reported that it improves postoperative outcomes, such as length of hospital stay and postoperative complications. This case report describes the benefits of preoperative cognitive behavioral and exercise therapy in a Korean patient undergoing LVAD implantation. V. Copyright © 2017 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.

  1. Radionuclide analysis of right and left ventricular response to exercise in patients with atrial and ventricular septal defects

    International Nuclear Information System (INIS)

    Peter, C.A.; Bowyer, K.; Jones, R.H.

    1983-01-01

    In patients with ventricular or atrial septal defect, the ventricle which is chronically volume overloaded might not appropriately respond to increased demand for an augmentation in output and thereby might limit total cardiac function. In this study we simultaneously measured right and left ventricular response to exercise in 10 normal individuals, 10 patients with ventricular septal defect (VSD), and 10 patients with atrial septal defect (ASD). The normal subjects increased both right and left ventricular ejection fraction, end-diastolic volume, and stroke volume to achieve a higher cardiac output during exercise. Patients with VSD failed to increase right ventricular ejection fraction, but increased right ventricular end-diastolic volume and stroke volume. Left ventricular end-diastolic volume did not increase in these patients but ejection fraction, stroke volume, and forward left ventricular output achieved during exercise were comparable to the response observed in healthy subjects. In the patients with ASD, no rest-to-exercise change occurred in either right ventricular ejection fraction, end-diastolic volume, or stroke volume. In addition, left ventricular end-diastolic volume failed to increase, and despite an increase in ejection fraction, left ventricular stroke volume remained unchanged from rest to exercise. Therefore, cardiac output was augmented only by the heart rate increase in these patients. Right ventricular function appeared to be the major determinant of total cardiac output during exercise in patients with cardiac septal defects and left-to-right shunt

  2. Screening for heart transplantation and left ventricular assist system

    DEFF Research Database (Denmark)

    Lund, Lars H; Trochu, Jean-Noel; Meyns, Bart

    2018-01-01

    BACKGROUND: Heart transplantation (HTx) and implantable left ventricular assist systems (LVAS) improve outcomes in advanced heart failure but may be underutilized. We hypothesized that screening can identify appropriate candidates. METHODS AND RESULTS: The ScrEEning for advanced Heart Failure...... treatment (SEE-HF) study was a multicentre prospective study screening patients with existing cardiac resynchronization therapy (CRT) and/or implantable cardioverter-defibrillator (ICD) for ejection fraction ≤40% and New York Heart Association (NYHA) class III-IV, and subsequently for guideline-based HTx...

  3. Arrhythmogenic right ventricular cardiomyopathy: contribution of different electrocardiographic techniques.

    Science.gov (United States)

    Moreira, Davide; Delgado, Anne; Marmelo, Bruno; Correia, Emanuel; Gama, Pedro; Pipa, João; Nunes, Luís; Santos, Oliveira

    2014-04-01

    Arrhythmogenic right ventricular cardiomyopathy, also known as arrhythmogenic right ventricular dysplasia, is a condition in which myocardium is replaced by fibrous or fibrofatty tissue, predominantly in the right ventricle. It is clinically characterized by potentially lethal ventricular arrhythmias, and is a leading cause of sudden cardiac death. Its prevalence is not known exactly but is estimated at approximately 1:5000 in the adult population. Diagnosis can be on the basis of structural and functional alterations of the right ventricle, electrocardiographic abnormalities (including depolarization and repolarization alterations and ventricular arrhythmias) and family history. Diagnostic criteria facilitate the recognition and interpretation of non-specific clinical features of this disease. The authors present a case in which the diagnosis of arrhythmogenic right ventricular cardiomyopathy was prompted by the suspicion of right ventricular disease on transthoracic echocardiography. This was confirmed by detection of epsilon waves on analysis of the ECG, which generally go unnoticed but in this case were the key to the diagnosis. Their presence was also shown by non-conventional ECG techniques such as modified Fontaine ECG. The course of the disease culminated in the occurrence of ventricular tachycardia, which prompted placement of an implantable cardioverter-defibrillator. Copyright © 2013 Sociedade Portuguesa de Cardiologia. Published by Elsevier España. All rights reserved.

  4. The effect of postoperative medical treatment on left ventricular mass regression after aortic valve replacement.

    Science.gov (United States)

    Helder, Meghana R K; Ugur, Murat; Bavaria, Joseph E; Kshettry, Vibhu R; Groh, Mark A; Petracek, Michael R; Jones, Kent W; Suri, Rakesh M; Schaff, Hartzell V

    2015-03-01

    The study objective was to analyze factors associated with left ventricular mass regression in patients undergoing aortic valve replacement with a newer bioprosthesis, the Trifecta valve pericardial bioprosthesis (St Jude Medical Inc, St Paul, Minn). A total of 444 patients underwent aortic valve replacement with the Trifecta bioprosthesis from 2007 to 2009 at 6 US institutions. The clinical and echocardiographic data of 200 of these patients who had left ventricular hypertrophy and follow-up studies 1 year postoperatively were reviewed and compared to analyze factors affecting left ventricular mass regression. Mean (standard deviation) age of the 200 study patients was 73 (9) years, 66% were men, and 92% had pure or predominant aortic valve stenosis. Complete left ventricular mass regression was observed in 102 patients (51%) by 1 year postoperatively. In univariate analysis, male sex, implantation of larger valves, larger left ventricular end-diastolic volume, and beta-blocker or calcium-channel blocker treatment at dismissal were significantly associated with complete mass regression. In the multivariate model, odds ratios (95% confidence intervals) indicated that male sex (3.38 [1.39-8.26]) and beta-blocker or calcium-channel blocker treatment at dismissal (3.41 [1.40-8.34]) were associated with increased probability of complete left ventricular mass regression. Patients with higher preoperative systolic blood pressure were less likely to have complete left ventricular mass regression (0.98 [0.97-0.99]). Among patients with left ventricular hypertrophy, postoperative treatment with beta-blockers or calcium-channel blockers may enhance mass regression. This highlights the need for close medical follow-up after operation. Labeled valve size was not predictive of left ventricular mass regression. Copyright © 2015 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

  5. The Cost-Effectiveness of Dual Mobility Implants for Primary Total Hip Arthroplasty: A Computer-Based Cost-Utility Model.

    Science.gov (United States)

    Barlow, Brian T; McLawhorn, Alexander S; Westrich, Geoffrey H

    2017-05-03

    Dislocation remains a clinically important problem following primary total hip arthroplasty, and it is a common reason for revision total hip arthroplasty. Dual mobility (DM) implants decrease the risk of dislocation but can be more expensive than conventional implants and have idiosyncratic failure mechanisms. The purpose of this study was to investigate the cost-effectiveness of DM implants compared with conventional bearings for primary total hip arthroplasty. Markov model analysis was conducted from the societal perspective with use of direct and indirect costs. Costs, expressed in 2013 U.S. dollars, were derived from the literature, the National Inpatient Sample, and the Centers for Medicare & Medicaid Services. Effectiveness was expressed in quality-adjusted life years (QALYs). The model was populated with health state utilities and state transition probabilities derived from previously published literature. The analysis was performed for a patient's lifetime, and costs and effectiveness were discounted at 3% annually. The principal outcome was the incremental cost-effectiveness ratio (ICER), with a willingness-to-pay threshold of $100,000/QALY. Sensitivity analyses were performed to explore relevant uncertainty. In the base case, DM total hip arthroplasty showed absolute dominance over conventional total hip arthroplasty, with lower accrued costs ($39,008 versus $40,031 U.S. dollars) and higher accrued utility (13.18 versus 13.13 QALYs) indicating cost-savings. DM total hip arthroplasty ceased being cost-saving when its implant costs exceeded those of conventional total hip arthroplasty by $1,023, and the cost-effectiveness threshold for DM implants was $5,287 greater than that for conventional implants. DM was not cost-effective when the annualized incremental probability of revision from any unforeseen failure mechanism or mechanisms exceeded 0.29%. The probability of intraprosthetic dislocation exerted the most influence on model results. This model

  6. Comparison of early versus delayed timing of left ventricular assist device implantation as a bridge-to-transplantation: An analysis of the UNOS dataset.

    Science.gov (United States)

    Kitada, Shuichi; Schulze, P Christian; Jin, Zhezhen; Clerkin, Kevin; Homma, Shunichi; Mancini, Donna M

    2016-01-15

    Placement of left ventricular assist devices (LVAD) as a bridge-to-heart transplantation (HTx) has rapidly expanded due to organ donor shortage. However, the timing of LVAD implantation is variable and it remains unclear if earlier implantation improves survival. We analyzed 14,187 adult candidates from the United Network of Organ Sharing database. Patients were classified by 3 treatment strategies including patients medically treated alone (MED, n=11,009), patients on LVAD support at listing (Early-LVAD, n=1588) and patients undergoing LVAD placement while awaiting HTx (Delayed-LVAD, n=1590). Likelihood of HTx and event-free survival were assessed in patients subcategorized by clinical strategies and UNOS status at listing. The device support strategy, despite the timing of placement, was not associated with increased likelihood of HTx compared to MED group. However, both LVAD implantation strategies showed better survival compared to MED group (Early-LVAD: HR 0.811 and 0.633, 95% CI 0.668-0.984 and 0.507-0.789, for 1A and 1B; p=0.034 and p<0.001, Delayed-LVAD: HR 0.553 and 0.696, 95% CI 0.415-0.736 and 0.571-0.847, for 1A and 1B; both p<0.001, respectively). Furthermore, there was no significant difference in survival between these LVAD implantation strategies in patients listed as 1B (p=0.500), although Early-LVAD implantation showed worse survival in patients listed as 1A (HR 1.467, 95% CI 1.076-2.000; p=0.015). LVAD support strategies offer a safe bridge-to-HTx. Those candidates who receive urgent upfront LVAD implantation for HTx, and improve to 1B status, would achieve competitive survival with those who receive elective LVAD implantation. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  7. [The complex origin of ventricular tachycardia after the total correction of tetralogy of Fallot].

    Science.gov (United States)

    Ressia, L; Graffigna, A; Salerno-Uriarte, J A; Viganò, M

    1993-09-01

    Two patients underwent surgical treatment of ventricular tachycardia after repair of tetralogy of Fallot. Both patients had right bundle branch block, moderate pulmonary valve incompetence and right ventricular dilatation, and were refractory to electrophysiologically guided drug therapy. Both patients underwent intraoperative epicardial mapping, which located the arrhythmogenic focus on the right ventricular outflow tract, on the border of the previous ventriculotomy. In one patient removal of the previous scar and endocardial cryoablation was successful in ablating the arrhythmia. In the other, the same procedure was only temporarily effective. VT recurred and was subsequently identified at the superior border of the closed ventricular septal defect. It was ablated by means of transcatheter radiofrequency. While VT from foci located on the right ventricular free wall can be easily detected and ablated, septal origin of VT requires extensive preoperative and intraoperative electrophysiological evaluation and may necessitate combined surgical and transcatheter procedures.

  8. Reverse Engineering Nature to Design Biomimetic Total Knee Implants.

    Science.gov (United States)

    Varadarajan, Kartik Mangudi; Zumbrunn, Thomas; Rubash, Harry E; Malchau, Henrik; Muratoglu, Orhun K; Li, Guoan

    2015-10-01

    While contemporary total knee arthroplasty (TKA) provides tremendous clinical benefits, the normal feel and function of the knee is not fully restored. To address this, a novel design process was developed to reverse engineer "biomimetic" articular surfaces that are compatible with normal soft-tissue envelope and kinematics of the knee. The biomimetic articular surface is created by moving the TKA femoral component along in vivo kinematics of normal knees and carving out the tibial articular surface from a rectangular tibial block. Here, we describe the biomimetic design process. In addition, we utilize geometric comparisons and kinematic simulations to show that; (1) tibial articular surfaces of conventional implants are fundamentally incompatible with normal knee motion, and (2) the anatomic geometry of the biomimetic surface contributes directly to restoration of normal knee kinematics. Such biomimetic implants may enable us to achieve the long sought after goal of a "normal" knee post-TKA surgery. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  9. Stent fracture, valve dysfunction, and right ventricular outflow tract reintervention after transcatheter pulmonary valve implantation: patient-related and procedural risk factors in the US Melody Valve Trial.

    Science.gov (United States)

    McElhinney, Doff B; Cheatham, John P; Jones, Thomas K; Lock, James E; Vincent, Julie A; Zahn, Evan M; Hellenbrand, William E

    2011-12-01

    Among patients undergoing transcatheter pulmonary valve (TPV) replacement with the Melody valve, risk factors for Melody stent fracture (MSF) and right ventricular outflow tract (RVOT) reintervention have not been well defined. From January 2007 to January 2010, 150 patients (median age, 19 years) underwent TPV implantation in the Melody valve Investigational Device Exemption trial. Existing conduit stents from a prior catheterization were present in 37 patients (25%, fractured in 12); 1 or more new prestents were placed at the TPV implant catheterization in 51 patients. During follow-up (median, 30 months), MSF was diagnosed in 39 patients. Freedom from a diagnosis of MSF was 77±4% at 14 months (after the 1-year evaluation window) and 60±9% at 39 months (3-year window). On multivariable analysis, implant within an existing stent, new prestent, or bioprosthetic valve (combined variable) was associated with longer freedom from MSF (Pbioprosthetic valve was associated with lower risk of MSF and reintervention.

  10. Deairing Techniques for Double-Ended Centrifugal Total Artificial Heart Implantation.

    Science.gov (United States)

    Karimov, Jamshid H; Horvath, David J; Byram, Nicole; Sunagawa, Gengo; Grady, Patrick; Sinkewich, Martin; Moazami, Nader; Sale, Shiva; Golding, Leonard A R; Fukamachi, Kiyotaka

    2017-06-01

    The unique device architecture of the Cleveland Clinic continuous-flow total artificial heart (CFTAH) requires dedicated and specific air-removal techniques during device implantation in vivo. These procedures comprise special surgical techniques and intraoperative manipulations, as well as engineering design changes and optimizations to the device itself. The current study evaluated the optimal air-removal techniques during the Cleveland Clinic double-ended centrifugal CFTAH in vivo implants (n = 17). Techniques and pump design iterations consisted of developing a priming method for the device and the use of built-in deairing ports in the early cases (n = 5). In the remaining cases (n = 12), deairing ports were not used. Dedicated air-removal ports were not considered an essential design requirement, and such ports may represent an additional risk for pump thrombosis. Careful passive deairing was found to be an effective measure with a centrifugal pump of this design. In this report, the techniques and design changes that were made during this CFTAH development program to enable effective residual air removal and prevention of air embolism during in vivo device implantation are explained. © 2016 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  11. Feasibility and Safety of Endovascular Stripping of Totally Implantable Venous Access Devices

    International Nuclear Information System (INIS)

    Heye, Sam; Maleux, Geert; Goossens, G. A.; Vaninbroukx, Johan; Jerôme, M.; Stas, M.

    2012-01-01

    Purpose: To evaluate the safety and feasibility of percutaneous stripping of totally implantable venous access devices (TIVAD) in case of catheter-related sleeve and to report a technique to free the catheter tip from vessel wall adherence. Materials and Methods: A total of 37 stripping procedures in 35 patients (14 men, 40%, and 21 women, 60%, mean age 53 ± 14 years) were reviewed. Totally implantable venous access devices were implanted because of malignancy in most cases (85.7%). Catheter-related sleeve was confirmed as cause of persistent catheter dysfunction despite instillation of thrombolytics. A technique to mobilize the catheter tip from the vessel wall was used when stripping with the snare catheter was impossible. Technical success, complication rate, and outcome were noted. Results: A total of 55.9% (n = 19) of the 34 technically successful procedures (91.9%) could be done with the snare catheter. In 15 cases (44.1%), additional maneuvers to free the TIVAD’s tip from the vessel wall were needed. Success rate was not significantly lower before (72.4%) than after (96.7%) implementation of the new technique (P = 0.09). No complications were observed. Follow-up was available in 67.6% of cases. Recurrent catheter dysfunction was found in 17 TIVADs (78.3%) at a mean of 137.7 days and a median of 105 days. Conclusions: Stripping of TIVADs is technically feasible and safe, with an overall success rate of 91.9%. Additional endovascular techniques to mobilize the distal catheter tip from the wall of the superior vena cava or right atrium to allow encircling the TIVAD tip with the snare catheter may be needed in 44.1% of cases.

  12. Exercise-Induced Ventricular Fibrillation: Seven Years Follow-Up

    Directory of Open Access Journals (Sweden)

    Gökmen Gemici

    2011-11-01

    Full Text Available We present a 7-year follow-up of a 55-year-old male who experienced ventricular fibrillation during the recovery period of exercise testing and refused implantation of an ICD. Normal left ventricular systolic function was found on echocardiographic examination, and coronary angiography revealed only a side branch disease with a vessel diameter of less than 2 millimeters. The patient was discharged on metoprolol and ASA in addition to his previous treatment with lisinopril and simvastatin. Outpatient cardiac evaluation by repeated 24-hour ECG monitorizations (Holter revealed normal findings. On follow up visits every six months for the past seven years, the patient was found to be asymptomatic.

  13. Heart rhythm at the time of death documented by an implantable loop recorder

    DEFF Research Database (Denmark)

    Gang, Uffe Jakob Ortved; Jøns, Christian; Jørgensen, Rikke Mørch

    2010-01-01

    The aims of this study were to describe arrhythmias documented with an implantable loop recorder (ILR) in post-acute myocardial infarction (AMI) patients with left ventricular dysfunction at the time of death and to establish the correlation to mode of death.......The aims of this study were to describe arrhythmias documented with an implantable loop recorder (ILR) in post-acute myocardial infarction (AMI) patients with left ventricular dysfunction at the time of death and to establish the correlation to mode of death....

  14. Association of air pollution with increased incidence of ventricular tachyarrhythmias recorded by implantable cardioverter defibrillators: Vulnerable patients to air pollution.

    Science.gov (United States)

    Kim, In-Soo; Sohn, Jungwoo; Lee, Seung-Jun; Park, Jin-Kyu; Uhm, Jae-Sun; Pak, Hui-Nam; Lee, Moon-Hyoung; Kim, Changsoo; Joung, Boyoung

    2017-08-01

    This study investigated the acute effects of exposure to air pollution on ventricular tachyarrhythmias (VTAs) in an East Asian population. The association between air pollution and VTA has not yet been studied in an East Asian country affected by the Asian dust phenomenon, which worsens air quality. The study cohort consisted of 160patients with implantable cardioverter defibrillator (ICD) devices in the Seoul metropolitan area who were followed for 5.5±3.8years. We used ICD records of VTAs and matched these with hourly measurements of air pollutant concentrations and meteorological data. Fine particle mass and gaseous air pollution plus temperature and relative humidity were measured hourly during the study period. During the study period, 1064 VTA events including 204 instances of ventricular fibrillation (VF) were observed. We found a statistically significant association between overall VTA events and SO 2 (lag 24h; OR 1.49, 95%CI 1.16-1.92, p=0.002), PM 10 (lag 2h; OR 2.56, 95%CI 2.03-3.23, pair pollution and VTA were observed in a metropolitan area of an East Asian country. Exposures to SO 2 , PM 10 , NO 2 , and CO were significantly associated with VTAs in ICD patients with SHD. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Extracorporeal Life Support Bridge to Ventricular Assist Device: The Double Bridge Strategy.

    Science.gov (United States)

    Marasco, Silvana F; Lo, Casey; Murphy, Deirdre; Summerhayes, Robyn; Quayle, Margaret; Zimmet, Adam; Bailey, Michael

    2016-01-01

    In patients requiring left ventricular assist device (LVAD) support, it can be difficult to ascertain suitability for long-term mechanical support with LVAD and eventual transplantation. LVAD implantation in a shocked patient is associated with increased morbidity and mortality. Interest is growing in the utilization of extracorporeal life support (ECLS) as a bridge-to-bridge support for these critically unwell patients. Here, we reviewed our experience with ECLS double bridging. We hypothesized that ECLS double bridging would stabilize end-organ dysfunction and reduce ventricular assist device (VAD) implant perioperative mortality. We conducted a retrospective review of prospectively collected data for 58 consecutive patients implanted with a continuous-flow LVAD between January 2010 and December 2013 at The Alfred Hospital, Melbourne, Victoria, Australia. Twenty-three patients required ECLS support pre-LVAD while 35 patients underwent LVAD implantation without an ECLS bridge. Preoperative morbidity in the ECLS bridge group was reflected by increased postoperative intensive care duration, blood loss, blood product use, and postoperative renal failure, but without negative impact upon survival when compared with the no ECLS group. ECLS stabilization improved end-organ function pre-VAD implant with significant improvements in hepatic and renal dysfunction. This series demonstrates that the use of ECLS bridge to VAD stabilizes end-organ dysfunction and reduces VAD implant perioperative mortality from that traditionally reported in these "crash and burn" patients. Copyright © 2015 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  16. A Prospective Study of Ripple Mapping the Post-Infarct Ventricular Scar to Guide Substrate Ablation for Ventricular Tachycardia.

    Science.gov (United States)

    Luther, Vishal; Linton, Nick W F; Jamil-Copley, Shahnaz; Koa-Wing, Michael; Lim, Phang Boon; Qureshi, Norman; Ng, Fu Siong; Hayat, Sajad; Whinnett, Zachary; Davies, D Wyn; Peters, Nicholas S; Kanagaratnam, Prapa

    2016-06-01

    Post-infarct ventricular tachycardia is associated with channels of surviving myocardium within scar characterized by fractionated and low-amplitude signals usually occurring late during sinus rhythm. Conventional automated algorithms for 3-dimensional electro-anatomic mapping cannot differentiate the delayed local signal of conduction within the scar from the initial far-field signal generated by surrounding healthy tissue. Ripple mapping displays every deflection of an electrogram, thereby providing fully informative activation sequences. We prospectively used CARTO-based ripple maps to identify conducting channels as a target for ablation. High-density bipolar left ventricular endocardial electrograms were collected using CARTO3v4 in sinus rhythm or ventricular pacing and reviewed for ripple mapping conducting channel identification. Fifteen consecutive patients (median age 68 years, left ventricular ejection fraction 30%) were studied (6 month preprocedural implantable cardioverter defibrillator therapies: median 19 ATP events [Q1-Q3=4-93] and 1 shock [Q1-Q3=0-3]). Scar (ripple mapping conducting channels were seen within each scar (length 60 mm; initial component 0.44 mV; delayed component 0.20 mV; conduction 55 cm/s). Ablation was performed along all identified ripple mapping conducting channels (median 18 lesions) and any presumed interconnected late-activating sites (median 6 lesions; Q1-Q3=2-12). The diastolic isthmus in ventricular tachycardia was mapped in 3 patients and colocated within the ripple mapping conducting channels identified. Ventricular tachycardia was noninducible in 85% of patients post ablation, and 71% remain free of ventricular tachycardia recurrence at 6-month median follow-up. Ripple mapping can be used to identify conduction channels within scar to guide functional substrate ablation. © 2016 American Heart Association, Inc.

  17. Failure of total hip implants: metals and metal release in 52 cases

    DEFF Research Database (Denmark)

    Jakobsen, Stig Storgaard; Lidén, Carola; Søballe, Kjeld

    2014-01-01

    Background . The pathogenesis of total joint replacement failure is multifactorial. One hypothesis suggests that corrosion and wear of alloys result in metal ion release, which may then cause sensitization and even implant failure, owing to the acquired immune reactivity. Objectives . To assess c...

  18. [Ventricular tachyarrhythmias in patients with cardiomyopathy

    DEFF Research Database (Denmark)

    Henningsen, K.; Christensen, A.H.; Svendsen, Jesper Hastrup

    2008-01-01

    by disease, gender, age, previous cardiac arrest and treatment with implantable cardioverter-defibrillator (ICD). RESULTS: 993 patients were screened and 128 patients with cardiomyopathy were identified, corresponding to 13% of the screened patients. 58 (45%) of the patients had dilated cardiomyopathy (DCM......), 57 (45%) patients had arrhythmogenic right ventricular cardiomyopathy (ARVC) and 13 (10%) had hypertrophic cardiomyopathy (HCM). The average age was 44 years for HCM, 41 years for ARVC and 58 years for DCM. The majority of the patients were male. ICD treatment was used in 95% of the patients...... with ARVC, 70% of the patients with HCM and 59% of the patients with DCM. Only 5 patients had previous cardiac arrest without reversible cause. CONCLUSION: The study shows that cardiomyopathies are relatively frequent causes of ventricular tachyarrhythmias in patients discharged from a specialised...

  19. Supracristal ventricular septal defect with severe right coronary cusp prolapse

    International Nuclear Information System (INIS)

    Hussain, A.H.; Hanif, B.; Khan, G.; Hasan, K.

    2011-01-01

    The case of a 20 years old male, diagnosed as supracristal ventricular septal defect (VSD) for last 6 years is being presented. He came in emergency department with decompensated congestive cardiac failure. After initial stabilization, he underwent trans thoracic echocardiogram which showed large supracristal VSD, severely prolapsing right coronary cusp, severe aortic regurgitation and severe pulmonary hypertension. Right heart catheterization was performed which documented reversible pulmonary vascular resistance after high flow oxygen inhalation. He underwent VSD repair, right coronary cusp was excised and aortic valve was replaced by mechanical prosthesis. Post operative recovery was uneventful. He was discharged home in one week.The case of a 20 years old male, diagnosed as supracristal ventricular septal defect (VSD) for last 6 years is being presented. He came in emergency department with decompensated congestive cardiac failure. After initial stabilization, he underwent trans thoracic echocardiogram which showed large supracristal VSD, severely prolapsing right coronary cusp, severe aortic regurgitation and severe pulmonary hypertension. Right heart catheterization was performed which documented reversible pulmonary vascular resistance after high flow oxygen inhalation. He underwent VSD repair, right coronary cusp was excised and aortic valve was replaced by mechanical prosthesis. Post operative recovery was uneventful. He was discharged home in one week. (author)

  20. Noninvasive diagnosis of suspected severe pulmonary embolism. Trans-esophageal echocardiography vs spiral CT

    International Nuclear Information System (INIS)

    Pruszczyk, P.; Torbicki, A.; Pacho, R.

    1998-01-01

    Patients with pulmonary embolism (PE) and echocardiographic signs of right ventricular over-lead have worse prognosis and may be require aggressive therapy. Unequivocal confirmation of PE is required before thrombolysis or embolectomy. This study compares the value of trans-esophageal echocardiography (TEE) and spiral CT (sCT) in direct visualization of pulmonary artery thrombo-emboli in patients with suspected PE and echocardiographic signs of right ventricular over-lead. Because of high prevalence of bilateral central pulmonary thrombo-emboli in patients with hemo-dynamically significant PE, both sCT and TEE allow its definitive confirmation in most cases. Thrombi reported by sCT distally to lobar arteries should be interpreted with caution. (author)

  1. A novel method of placing right ventricular leads in patients with persistent left superior vena cava using a conventional j stylet.

    Science.gov (United States)

    Mora, Guillermo

    2014-03-01

    Locating pacemaker electrodes can become complicated by congenital abnormalities such as persistent left superior vena cava (LSVC). To evaluate a technique for the implanting of ventricular electrode in patients with persistent LSVC. The study was carried out from June 2001 to June 2010 involving all patients who were admitted to the Hospital Universitario Mayor, Instituto de Corazon de Bogota and Hospital Universitario Clinica San Rafael (Bogota-Colombia) for implanting pacemakers or cardiac defibrillators. LSVC was diagnosed by fluoroscopic observation (anterior-posterior view) of the course of the stylet. Four steps were followed: 1) Move the electrode with a straight stylet to the right atrium. 2) Change the straight stylet by a conventional J stylet and push the electrode to the lateral or anterolateral wall of the right atrium. 3) Remove the guide 3-5 cm and 4) Push the electrode which crosses the tricuspid valve into the right ventricle and finally deploy the active fixation mechanism. A total of 1198 patients were admitted for pacemaker or cardiac defibrillator implant during the 9-year study period, 1114 received a left subclavian venous approach. There were 573 males and 541 females. Persistent LSVC was found in five patients (0.45%) Fluoroscopy time for implanting the ventricular electrode ranged from 60 to 250 seconds, 40 to 92 minutes being taken to complete the whole procedure. We present a simple and rapid technique for electrode placement in patients with LSVC using usual J guide and active fixation electrodes with high success.

  2. Ventricular Pacing via the Coronary Sinus in a Patient with a Mechanical Tricuspid Valve Prosthesis

    Directory of Open Access Journals (Sweden)

    Janice Swampillai, MD

    2011-01-01

    Full Text Available Implantation of a transvenous endocardial pacing lead in the right ventricle is contra-indicated after mechanical tricuspid valve replacement; therefore a surgical approach to the epicardium is usually required. This case report describes ventricular pacing via a branch of the coronary sinus in a patient with mechanical mitral, aortic and tricuspid valve replacements. In conclusion, this approach is minimally invasive, provides effective ventricular stimulation with low pacing threshold and stable lead position, and is a feasible option when transvenous right ventricular pacing is not possible.

  3. Complications after percutaneous placement of totally implantable venous access ports in the forearm

    International Nuclear Information System (INIS)

    Goltz, J.P.; Petritsch, B.; Thurner, A.; Hahn, D.; Kickuth, R.

    2012-01-01

    This article focuses on radiological imaging of complications after interventional percutaneous insertion of totally implantable venous access ports (TIVAPs) which were placed in the forearm. Thus far most reviews have dealt with pectorally-placed TIVAPs. Compared with the pectoral approach, implantation in the forearm has been associated with certain complications owing to a longer route of the port catheter within a smaller vein, and owing to the route across the elbow joint, resulting in higher rates of catheter-associated thrombosis and possible mechanical complications. The purpose of this review is to describe the complications after implantation of TIVAPs in the forearm, and to make radiologists familiar with the key findings of the complications during radiological imaging, including colour-coded and compression Duplex ultrasound, computed tomography, and digital subtraction venography.

  4. Survey of the trans-resveratrol and trans-piceid content of cocoa-containing and chocolate products.

    Science.gov (United States)

    Hurst, W Jeffrey; Glinski, Jan A; Miller, Kenneth B; Apgar, Joan; Davey, Matthew H; Stuart, David A

    2008-09-24

    Dietary resveratrol (3,4',5-trihydroxystilbene) has been implicated in the health benefits associated with grapes and red wine, more specifically with potential benefits for metabolic syndrome, energy use, and increased endurance. Levels of trans-resveratrol and its glucoside, trans-piceid, were determined in 19 top selling commercially available cocoa-containing and chocolate products from the U.S. market. Amounts of trans-resveratrol and trans-piceid were closely correlated with the amount of nonfat cocoa solids (NFCS) in the cocoa-containing products. Among these products, trans-resveratrol levels were highest in cocoa powders (1.85 +/- 0.43 microg/g), followed by unsweetened baking chocolates (1.24 +/- 0.22), semisweet chocolate baking chips (0.52 +/- 0.14), dark chocolates (0.35 +/- 0.08), milk chocolates (0.10 +/- 0.05), and chocolate syrups (0.09 +/- 0.02). These cocoa-containing and chocolate products have about 3-5 times more trans-piceid than trans-resveratrol. Levels of trans-piceid were highest in the cocoa powders (7.14 +/- 0.80 microg/g), followed by unsweetened baking chocolates (4.04 +/- 0.14), semisweet chocolate baking chips (2.01 +/- 0.18), dark chocolates (1.82 +/- 0.36), milk chocolates (0.44 +/- 0.06), and chocolate syrups (0.35 +/- 0.06). On an equal weight basis, cocoa powder had about half as much trans-resveratrol as the average California red wine. On a per serving basis, cocoa-containing and chocolate products had less trans-resveratrol than red wine and grape juice but more than roasted peanuts. Overall, these cocoa-containing and chocolate products rank second after red wines and grape juice in foods with the highest levels of total trans-resveratrol in the diet.

  5. Effect of weaning status on lipids of Galician Blond veal: total fatty acids and 18:1 cis and trans isomers.

    Science.gov (United States)

    Bispo, Esperanza; Moreno, Teresa; Latorre, Alicia; González, Laura; Herradón, Pedro G; Franco, Daniel; Monserrat, Lorenzo

    2010-10-01

    The effect of weaning at different ages (NW=not weaned, W5=5.5 months and W2=2 months) on fatty acids (FA) of the Longissimus thoracis (LT) muscle was studied in 36 Galician Blond (GB) calves. Total FA (TFA) were determined by gas chromatography (GC) and 18:1 isomers by a combination of reversed-phase high performance liquid chromatography (HPLC) and GC. NW group showed higher (Pconjugated linoleic acid (CLA) and 18:1 trans-11 compared to LT from W5 and W2 calves. W2 calves showed the highest levels of n-6 PUFA (P<0.01), 18:1 trans-10 and 18:1 trans-6/7/8 (P<0.001). Generally, W5 calves had intermediate values for TFA and 18:1 isomers. As the suckling period was longer, GB milk and veal FA profiles became more similar, it seems that muscle FA were partially transmitted by the milk FA intake due to the persistence of the reticular grove closing reflex. Copyright (c) 2010 The American Meat Science Association. Published by Elsevier Ltd.. All rights reserved.

  6. Implantable defibrillator therapy: more than defibrillation...

    NARCIS (Netherlands)

    D.A.M.J. Theuns (Dominic)

    2005-01-01

    textabstractDuring the past 25 years, the implantable cardioverter-defibrillator (ICD) has evolved from the treatment of last resort to the gold standard for patients at high risk for life­threatening ventricular tachyarrhythmias. Patients at high risk include those who survived life-threatening

  7. Choice of implant combinations in total hip replacement: systematic review and network meta-analysis.

    Science.gov (United States)

    López-López, José A; Humphriss, Rachel L; Beswick, Andrew D; Thom, Howard H Z; Hunt, Linda P; Burston, Amanda; Fawsitt, Christopher G; Hollingworth, William; Higgins, Julian P T; Welton, Nicky J; Blom, Ashley W; Marques, Elsa M R

    2017-11-02

    Objective  To compare the survival of different implant combinations for primary total hip replacement (THR). Design  Systematic review and network meta-analysis. Data sources  Medline, Embase, The Cochrane Library, ClinicalTrials.gov, WHO International Clinical Trials Registry Platform, and the EU Clinical Trials Register. Review methods  Published randomised controlled trials comparing different implant combinations. Implant combinations were defined by bearing surface materials (metal-on-polyethylene, ceramic-on-polyethylene, ceramic-on-ceramic, or metal-on-metal), head size (large ≥36 mm or small meta-analysis for revision. There was no evidence that the risk of revision surgery was reduced by other implant combinations compared with the reference implant combination. Although estimates are imprecise, metal-on-metal, small head, cemented implants (hazard ratio 4.4, 95% credible interval 1.6 to 16.6) and resurfacing (12.1, 2.1 to 120.3) increase the risk of revision at 0-2 years after primary THR compared with the reference implant combination. Similar results were observed for the 2-10 years period. 31 studies (2888 patients) were included in the analysis of Harris hip score. No implant combination had a better score than the reference implant combination. Conclusions  Newer implant combinations were not found to be better than the reference implant combination (metal-on-polyethylene (not highly cross linked), small head, cemented) in terms of risk of revision surgery or Harris hip score. Metal-on-metal, small head, cemented implants and resurfacing increased the risk of revision surgery compared with the reference implant combination. The results were consistent with observational evidence and were replicated in sensitivity analysis but were limited by poor reporting across studies. Systematic review registration  PROSPERO CRD42015019435. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence

  8. Ongoing right ventricular hemodynamics in heart failure: clinical value of measurements derived from an implantable monitoring system.

    Science.gov (United States)

    Adamson, Philip B; Magalski, Anthony; Braunschweig, Frieder; Böhm, Michael; Reynolds, Dwight; Steinhaus, David; Luby, Allyson; Linde, Cecilia; Ryden, Lars; Cremers, Bodo; Takle, Teri; Bennett, Tom

    2003-02-19

    This study examined the characteristics of continuously measured right ventricular (RV) hemodynamic information derived from an implantable hemodynamic monitor (IHM) in heart failure patients. Hemodynamic monitoring might improve the day-to-day management of patients with chronic heart failure (CHF). Little is known about the characteristics of long-term hemodynamic information in patients with CHF or how such information relates to meaningful clinical events. Thirty-two patients with CHF received a permanent RV IHM system similar to a single-lead pacemaker. Right ventricular systolic and diastolic pressures, heart rate, and pressure derivatives were continuously measured for nine months without using the data for clinical decision-making or management of patients. Data were then made available to clinical providers, and the patients were followed up for 17 months. Pressure characteristics during optimal volume, clinically determined volume-overload exacerbations, and volume depletion events were examined. The effect of IHM on hospitalizations was examined using the patients' historical controls. Long-term RV pressure measurements had either marked variability or minimal time-related changes. During 36 volume-overload events, RV systolic pressures increased by 25 +/- 4% (p < 0.05) and heart rate increased by 11 +/- 2% (p < 0.05). Pressure increases occurred in 9 of 12 events 4 +/- 2 days before the exacerbations requiring hospitalization. Hospitalizations before using IHM data for clinical management averaged 1.08 per patient year and decreased to 0.47 per patient-year (57% reduction, p < 0.01) after hemodynamic data were used. Long-term ambulatory pressure measurements from an IHM may be helpful in guiding day-to-day clinical management, with a potentially favorable impact on CHF hospitalizations.

  9. Transcatheter coil occluder for closure of ventricular septal defect (a report of 4 cases)

    International Nuclear Information System (INIS)

    Gao Wei; Zhou Aiqing; Yu Zhiqing; Li Fen; Zhong Yumin; Zhang Yuqi; Huang Meirong; Sun Kun

    2005-01-01

    Objective: To explore the indication, methodology and complication of transcatheter coil closure of ventricular septal defect (VSD) in children. Methods: Transcatheter closure of perimembranous VSD with coils was performed in 4 cases from 2003 to 2005. The Duct-Occlude (pfm) and detachable coil (Cook) were chosen for embolization depending on the results of the left ventricular angiogram. The coil size was generally about 1-4 mm larger than the diameter of VSD. Follow up was carried out with echocardiography, ultrasound and clinical examination. Results: The defect diameters of the four cases were 2.0 mm, 2.7 mm, 2.5 mm and 1.5 mm respectively. The Duct-Occlude were successfully implanted in 3 cases of perimembranous VSD with the same type coil (OD[mm]7-3-6, windings 5-3-4) for each. One detachable coil (Cook) (5 x 5) was implanted in the remaining case. All cases had trivial residual shunt immediately after implantation which disappeared 24 hours later. Follow-up for 2 months to one year showed no coil displacement and secondary bacterial arteritis. No tricuspid and aortic regurgitation, no emboli, no endocarditis, and no arrhythmia were found. Conclusions: Coil closure of some small VSD with membranate part pseudo-ventricular aneurysm has good efficacy with the advantages of simple operation, less metal content and mini-invasion also applicable for infants. (authors)

  10. EXPERIMENTAL RESEARCH OF REGENERATIVE FEATURES IN BONE TISSUES AROUND IMPLANTS AFTER ONE-STAGE BILATERAL TOTAL HIP REPLACEMENT

    Directory of Open Access Journals (Sweden)

    V. M. Mashkov

    2012-01-01

    Full Text Available Objective: to research the specific features of regenerative processes of bone tissue around implants after one-stage bilateral total hip replacement in experiment. Material and methods: 27 total hip replacement operations have been performed in 18 rabbits of breed "chinchilla" to which bipolar femoral endoprosthesis made of titanic alloy PT-38, one type-size, with friction pair metal-on-metal and neck-shaft angle 165 degrees have been implanted: total unilateral hip replacement operations have been performed in 9 animals (control group, one-stage bilateral total hip replacement operations have been performed in 9 animals (experimental group. During research they have been on radiological and clinical checking-up. After the experiment the animals had histological tests of the tissues around endoprosthesis components. Results and conclusions: After one-stage bilateral total hip replacement in early terms of research more expressed changes of bone tissue in the form of its thinning and decompaction were found around implants. One-stage bilateral total hip replacement did not essentially influence on the speed of osteogenesis around endoprothesis components in comparison with unilateral total hip replacement, so in late terms of observation in both groups the fixing of endoprothesis components did not differ.

  11. The Achilles' heel of left ventricular assist device therapy: right ventricle.

    Science.gov (United States)

    Ranganath, Neel K; Smith, Deane E; Moazami, Nader

    2018-06-01

    Many patients suffer from either persistent right ventricular failure (RVF) at the time of left ventricular assist device (LVAD) or have ongoing symptoms consistent with RVF during chronic mechanical circulatory support. The lack of long-term right ventricular assist devices (RVADs) has limited the impact that mechanical circulatory support can provide to patients with biventricular failure. We aim to review the entire spectrum of RVF in patients receiving LVADs and reflect on why this entity remains the Achilles' heel of LVAD therapy. In the early postoperative period, LVAD implantation reduces right ventricle (RV) afterload, but RV dysfunction may be exacerbated secondary to increased venous return. With prolonged therapy, the decreased RV afterload leads to improved RV contractile function. Bayesian statistical models outperform previously published preoperative risk scores by considering inter-relationships and conditional probabilities amongst independent variables. Various echocardiographic parameters and the pulmonary artery pulsatility index have shown promise in predicting post-LVAD RVF. Recent publications have delineated the emergence of 'delayed' RVF. Several devices are currently being investigated for use as RVADs. Post-LVAD RVF depends on the RV's ability to adapt to acute hemodynamic changes imposed by the LVAD. Management options are limited due to the lack of an easily implantable, chronic-use RVAD.

  12. Electromagnetic Compatibility of Transcutaneous Energy Transmission Systemfor Totally Implantable Artificial Heart

    Science.gov (United States)

    Shiba, Kenji; Koshiji, Kohji

    Transcutaneous Energy Transmission (TET) is one way of providing the energy needed to power a totally implantable artificial heart (TIAH). In the present study, an externally coupled TET system was implanted in a prototype human phantom to evaluate emission and immunity. In the emission evaluation, measurements were conducted based on CISPR Pub.11 and VDE 0871 standards, while immunity tests were based on the standards of the IEC 61000-4 series. The magnetic field of the radiated emission was measured using a loop antenna. At 0.1[MHz], we found the greatest magnetic field of 47.8 [dBμA/m], somewhat less than CISPR’s upper limit of 54 [dBμA/m]. For the conducted emission, by installing a noise filter and ferrite beads in the input section of the DC-power supply, conducted emission could be kept within the allowable limits of CISPR Pub.11 and VDE 0871. Finally, the immunity tests against radiated and conducted emission, electrostatic discharge and voltage fluctuation proved that the prototype could withstand the maximum level of disturbance. These results confirmed that the TET system implanted in a human phantom could, through modification, meet the emission and immunity standards.

  13. Haemodynamic effects of dual-chamber pacing versus ventricular pacing during a walk test in patients with depressed or normal left ventricular function

    Energy Technology Data Exchange (ETDEWEB)

    Ferro, Adele; Salvatore, Marco; Cuocolo, Alberto [University Federico II, Department of Biomorphological and Functional Sciences, Institute of Biostructure and Bioimages of the National Council of Research, Naples (Italy); Duilio, Carlo; Santomauro, Maurizio [University Federico II, Department of Clinical Medicine, Cardiovascular and Immunological Sciences, Naples (Italy)

    2005-09-01

    Dual-chamber rate-modulated pacing provides haemodynamic benefits compared with ventricular pacing at rest, but it is unclear whether this also holds true during physical exercise in patients with heart failure. This study assessed the haemodynamic response to a walk test during dual-chamber pacing and ventricular pacing in patients with depressed or normal left ventricular (LV) function. Twelve patients with an LV ejection fraction <50% and 11 patients with an LV ejection fraction {>=}50% underwent two randomised 6-min walk tests under dual-chamber rate-modulated pacing and ventricular pacing at a fixed rate of 70 beats/min. All patients had a dual-chamber pacemaker implanted for complete heart block. LV function was monitored by a radionuclide ambulatory system. In patients with depressed LV function, the change from dual-chamber pacing to ventricular pacing induced a decrease in end-systolic volume at the peak of the walk test (P<0.05), with no difference in end-diastolic volume. As a consequence, higher increases in LV ejection fraction (P<0.0001) and stroke volume (P<0.01) were observed during ventricular pacing. No difference in cardiac output was found between the two pacing modes. In patients with normal LV function, the change from dual-chamber pacing to ventricular pacing induced a significant decrease in cardiac output (P<0.005 at rest and P<0.05 at the peak of the walk test). Compared with dual-chamber rate-modulated pacing, ventricular pacing improves cardiac function and does not affect cardiac output during physical activity in patients with depressed LV function, whereas it impairs cardiac output in those with normal function. (orig.)

  14. Haemodynamic effects of dual-chamber pacing versus ventricular pacing during a walk test in patients with depressed or normal left ventricular function

    International Nuclear Information System (INIS)

    Ferro, Adele; Salvatore, Marco; Cuocolo, Alberto; Duilio, Carlo; Santomauro, Maurizio

    2005-01-01

    Dual-chamber rate-modulated pacing provides haemodynamic benefits compared with ventricular pacing at rest, but it is unclear whether this also holds true during physical exercise in patients with heart failure. This study assessed the haemodynamic response to a walk test during dual-chamber pacing and ventricular pacing in patients with depressed or normal left ventricular (LV) function. Twelve patients with an LV ejection fraction <50% and 11 patients with an LV ejection fraction ≥50% underwent two randomised 6-min walk tests under dual-chamber rate-modulated pacing and ventricular pacing at a fixed rate of 70 beats/min. All patients had a dual-chamber pacemaker implanted for complete heart block. LV function was monitored by a radionuclide ambulatory system. In patients with depressed LV function, the change from dual-chamber pacing to ventricular pacing induced a decrease in end-systolic volume at the peak of the walk test (P<0.05), with no difference in end-diastolic volume. As a consequence, higher increases in LV ejection fraction (P<0.0001) and stroke volume (P<0.01) were observed during ventricular pacing. No difference in cardiac output was found between the two pacing modes. In patients with normal LV function, the change from dual-chamber pacing to ventricular pacing induced a significant decrease in cardiac output (P<0.005 at rest and P<0.05 at the peak of the walk test). Compared with dual-chamber rate-modulated pacing, ventricular pacing improves cardiac function and does not affect cardiac output during physical activity in patients with depressed LV function, whereas it impairs cardiac output in those with normal function. (orig.)

  15. Pacemaker Implantation Associated Myocardial Micro-Damage: A Randomised Comparison between Active and Passive Fixation Leads.

    Science.gov (United States)

    Blažek, Patrick; Ferri-Certić, Jerko; Vražić, Hrvoje; Lennerz, Carsten; Grebmer, Christian; Kaitani, Kazuaki; Karch, Martin; Starčević, Boris; Semmler, Verena; Kolb, Christof

    2018-03-20

    Fixation of the pacemaker leads during pacemaker implantation leads to an increase of cardiac Troponin T (cTnT) that can be interpreted as a sign of minimal myocardial damage. This trial evaluates whether the mechanism type of lead fixation influences the magnitude of cTnT release. Patients having a de-novo cardiac pacemaker implantation or a lead revision were centrally randomized to receive either a ventricular lead with an active (screw) or passive (tine) fixation mechanism. High-sensitive Troponin T (hsTnT) was determined on the day of the procedure beforehand and on the following day. 326 Patients (median age (IQR) 75.0 (69.0-80.0) years, 64% male) from six international centers were randomized to receive ventricular leads with an active (n = 166) or passive (n = 160) fixation mechanism. Median (IQR) hsTnT levels increased by 0.009 (0.004-0.021) ng/ml in the group receiving screw-in ventricular leads and by 0.008 (0.003-0.030) ng/ml in the group receiving tined ventricular leads (n.s.). In conclusion pacemaker implantations are followed by a release of hsTnT. The choice between active or passive fixation ventricular leads does not have a significant influence on the extent of myocardial injury and the magnitude of hsTnT release.

  16. [CONTENT OF TRANS FATTY ACIDS IN FOOD PRODUCTS IN SPAIN].

    Science.gov (United States)

    Robledo de Dios, Teresa; Dal Re Saavedra, M Ángeles; Villar Villalba, Carmen; Pérez-Farinós, Napoleón

    2015-09-01

    trans fatty acids are associated to several health disorders, as ischemic heart disease or diabetes mellitus. to assess the content of trans fatty acids in products in Spain, and the percentage of trans fatty acids respecting total fatty acids. 443 food products were acquired in Spain, and they were classified into groups. The content in fatty acids was analyzed using gas chromatography. Estimates of central tendency and variability of the content of trans fatty acids in each food group were computed (in g of trans fatty acids/100 g of product). The percentage of trans fatty acids respecting total fatty acids was calculated in each group. 443 products were grouped into 42 groups. Median of trans fatty acids was less than 0.55 g / 100 g of product in all groups except one. 83 % of groups had less than 2 % of trans fatty acids, and 71 % of groups had less than 1 %. the content of trans fatty acids in Spain is low, and it currently doesn't play a public health problem. Copyright AULA MEDICA EDICIONES 2014. Published by AULA MEDICA. All rights reserved.

  17. Arrhythmogenic right ventricular dysplasia: Atypical clinical presentation.

    Science.gov (United States)

    Marçalo, José; Menezes Falcão, Luiz

    2017-03-01

    A 67-year-old man was admitted to our hospital after episodes of syncope preceded by malaise and diffuse neck and chest discomfort. No family history of cardiac disease was reported. Laboratory workup was within normal limits, including D-dimers, serum troponin I and arterial blood gases. The electrocardiogram showed sinus rhythm with T-wave inversion in leads V1 to V3. Computed tomography angiography to investigate pulmonary embolism showed no abnormal findings. Transthoracic echocardiography (TTE) displayed massive enlargement of the right ventricle with intact interatrial septum and no pulmonary hypertension. Cardiac magnetic resonance imaging (MRI) confirmed right ventricular (RV) dilatation and revealed marked hypokinesia/akinesia of the lateral wall. Exercise stress testing was negative for ischemia. According to the 2010 Task Force criteria for arrhythmogenic right ventricular dysplasia (ARVD), this patient presented two major criteria (global or regional dysfunction and structural alterations: by MRI, regional RV akinesia or dyskinesia or dyssynchronous RV contraction and RV ejection fraction ≤40%, and repolarization abnormalities: inverted T waves in right precordial leads [V1, V2, and V3]); and one minor criterion (>500 ventricular extrasystoles per 24 hours by Holter), and so a diagnosis of ARVD was made. After electrophysiologic study (EPS) the patient received an implantable cardioverter-defibrillator (ICD). This late clinical presentation of ARVD highlights the importance of TTE screening, possibly complemented by MRI. The associated risk of sudden death was assessed by EPS leading to the implantation of an ICD. Genetic association studies should be offered to the offspring of all ARVD patients. Copyright © 2016 Sociedade Portuguesa de Cardiologia. Publicado por Elsevier España, S.L.U. All rights reserved.

  18. Statins as anti-arrhythmics: a systematic review part II: effects on risk of ventricular arrhythmias.

    Science.gov (United States)

    Abuissa, Hussam; O'Keefe, James H; Bybee, Kevin A

    2009-10-01

    Recent studies have demonstrated that statins may possess anti-arrhythmic properties in addition to their lipid-lowering effects. Studies which reported the association of statins with the incidence of ventricular arrhythmias were identified through a systematic review of the published literature. Statins have been associated with a significant reductions in ventricular arrhythmia in cardiomyopathy patients with an implantable cardioverter defibrillator, although randomized trials have not been completed. Published data suggests that statins may possess anti-arrhythmic properties that reduce the propensity for ventricular arrhythmias. Most of this data is observational; more randomized, placebo-controlled trials are needed.

  19. Implant experience with an implantable hemodynamic monitor for the management of symptomatic heart failure.

    Science.gov (United States)

    Steinhaus, David; Reynolds, Dwight W; Gadler, Fredrik; Kay, G Neal; Hess, Mike F; Bennett, Tom

    2005-08-01

    Management of congestive heart failure is a serious public health problem. The use of implantable hemodynamic monitors (IHMs) may assist in this management by providing continuous ambulatory filling pressure status for optimal volume management. The Chronicle system includes an implanted monitor, a pressure sensor lead with passive fixation, an external pressure reference (EPR), and data retrieval and viewing components. The tip of the lead is placed near the right ventricular outflow tract to minimize risk of sensor tissue encapsulation. Implant technique and lead placement is similar to that of a permanent pacemaker. After the system had been successfully implanted in 148 patients, the type and frequency of implant-related adverse events were similar to a single-chamber pacemaker implant. R-wave amplitude was 15.2 +/- 6.7 mV and the pressure waveform signal was acceptable in all but two patients in whom presence of artifacts required lead repositioning. Implant procedure time was not influenced by experience, remaining constant throughout the study. Based on this evaluation, permanent placement of an IHM in symptomatic heart failure patients is technically feasible. Further investigation is warranted to evaluate the use of the continuous hemodynamic data in management of heart failure patients.

  20. The Managed Ventricular pacing versus VVI 40 Pacing (MVP) Trial: clinical background, rationale, design, and implementation.

    Science.gov (United States)

    Sweeney, Michael O; Ellenbogen, Kenneth A; Miller, Elaine Hogan; Sherfesee, Lou; Sheldon, Todd; Whellan, David

    2006-12-01

    Implantable cardioverter defibrillators (ICDs) reduce mortality among appropriately selected patients who have had or are at risk for life-threatening ventricular arrhythmia. Right ventricular apical (RVA) pacing has been implicated in worsening heart failure and death. The optimal pacemaker mode for bradycardia support while minimizing unnecessary and potentially harmful RVA pacing has not been determined. The Managed Ventricular pacing vs. VVI 40 Pacing Trial (MVP) is a prospective, multicenter, randomized, single-blind, parallel, controlled clinical trial designed to establish whether atrial-based dual-chamber managed ventricular pacing mode (MVP) is equivalent or superior to back-up only ventricular pacing (VVI 40) among patients with standard indications for ICD therapy and no indication for bradycardia pacing. The MVP Trial is designed with 80% power to detect a 10% reduction in the primary endpoint of new or worsening heart failure or all-cause mortality in the MVP-treated group. Approximately 1,000 patients at 80 centers in the United States, Canada, Western Europe, and Israel will be randomized to MVP or VVI 40 pacing after successful implantation of a dual-chamber ICD. Heart failure therapies will be optimized in accordance with evidence-based guidelines. Prespecified secondary endpoints will include ventricular arrhythmias, atrial fibrillation, new indication for bradycardia pacing, health-related quality of life, and cost effectiveness. Enrollment began in October 2004 and concluded in April 2006. The study will be terminated upon recommendation of the Data Monitoring Committee or when the last patient enrolled and surviving has reached a minimum 2 years of follow-up. The MVP Trial will meet the clinical need for carefully designed prospective studies to define the benefits of atrial-based dual-chamber minimal ventricular pacing versus single-chamber ventricular pacing in conventional ICD patients.

  1. Modo de inicio de las taquiarritmias ventriculares en la cardiopatía chagásica crónica

    OpenAIRE

    Rabinovich,Rafael F; Muratore,Claudio A; Baranchuk,Adrián

    2008-01-01

    Objetivo: El objetivo del estudio fue investigar el modo de inicio de las taquiarritmias ventriculares malignas (taquicardia/fibrilación ventricular) en pacientes con cardiopatía chagásica crónica, portadores de un cardiodesfibrilador implantable. Métodos: Se analizaron 179 episodios espontáneos de taquiarritmia ventricular a través de electrogramas endocavitarios almacenados en los cardiodesfibriladores de 15 pacientes con cardiopatía chagásica crónica. Se objetivaron 2 tipos de secuencia de...

  2. Sex and intimacy among patients with implantable left-ventricular assist devices.

    Science.gov (United States)

    Marcuccilli, Linda; Casida, Jesus Jessie; Peters, Rosalind M; Wright, Susan

    2011-01-01

    Left-ventricular assist devices (LVADs) sustain and improve the quality of life of people living with an advanced stage of heart failure. Past research focused on the development and advancement of LVAD technology, complications, and survival rates. Limited research addressed the psychosocial aspects of living with an LVAD, yet research related to sexual functioning and intimacy is lacking. The purpose of this study was to explore and describe sex and intimacy among adults living with an LVAD. We used an interpretive phenomenological study to explore the experiences of adults living with a long-term implantable LVAD, including the effect of the LVAD on their intimate and sexual functioning. Semistructured interviews were conducted with 7 men and 2 women, 31 to 70 years of age, who had lived with the LVAD at home for at least 3 months. Interviews were audiorecorded and transcribed. The wholistic and selective approach by van Manen (Researching Lived Experience: Human Science for an Action Sensitive Pedagogy. Albany, NY: SUNY Press; 1990) guided the analysis and interpretation of the transcribed interviews. Data were organized and coded into words and phrases using qualitative software. Three themes emerged from the data: (a) improved sexual relations with LVAD, (b) sexual adjustment, and (c) nonsexual intimacy. The themes identified were consistent with the concept of normalcy from the theory of self-care. Participants reported that as the LVAD improved their overall health, their sexual functioning also improved. Participants also reported an increased sense of connectedness and intimacy with their partners even in the absence of sexual intercourse. Participants discussed ways in which they continued to develop intimate relationships even in the presence of limitations in structural and functional integrity. The knowledge derived from this study can be used as a guide for healthcare providers in counseling LVAD recipients on psychosocial and sexual health essential

  3. Use of Cardiac Computed Tomography for Ventricular Volumetry in Late Postoperative Patients with Tetralogy of Fallot.

    Science.gov (United States)

    Kim, Ho Jin; Mun, Da Na; Goo, Hyun Woo; Yun, Tae-Jin

    2017-04-01

    Cardiac computed tomography (CT) has emerged as an alternative to magnetic resonance imaging (MRI) for ventricular volumetry. However, the clinical use of cardiac CT requires external validation. Both cardiac CT and MRI were performed prior to pulmonary valve implantation (PVI) in 11 patients (median age, 19 years) who had undergone total correction of tetralogy of Fallot during infancy. The simplified contouring method (MRI) and semiautomatic 3-dimensional region-growing method (CT) were used to measure ventricular volumes. All volumetric indices measured by CT and MRI generally correlated well with each other, except for the left ventricular end-systolic volume index (LV-ESVI), which showed the following correlations with the other indices: the right ventricular end-diastolic volume index (RV-EDVI) (r=0.88, p<0.001), the right ventricular end-systolic volume index (RV-ESVI) (r=0.84, p=0.001), the left ventricular end-diastolic volume index (LV-EDVI) (r=0.90, p=0.001), and the LV-ESVI (r=0.55, p=0.079). While the EDVIs measured by CT were significantly larger than those measured by MRI (median RV-EDVI: 197 mL/m 2 vs. 175 mL/m 2 , p=0.008; median LV-EDVI: 94 mL/m 2 vs. 92 mL/m 2 , p=0.026), no significant differences were found for the RV-ESVI or LV-ESVI. The EDVIs measured by cardiac CT were greater than those measured by MRI, whereas the ESVIs measured by CT and MRI were comparable. The volumetric characteristics of these 2 diagnostic modalities should be taken into account when indications for late PVI after tetralogy of Fallot repair are assessed.

  4. Implant Strategy-Specific Changes in Symptoms in Response to Left Ventricular Assist Devices.

    Science.gov (United States)

    Lee, Christopher S; Gelow, Jill M; Chien, Christopher V; Hiatt, Shirin O; Bidwell, Julie T; Denfeld, Quin E; Grady, Kathleen L; Mudd, James O

    Although we know that the quality of life generally improves after left ventricular assist device (LVAD) implantation, we know little about how symptoms change in response to LVAD. The purpose of this study was to compare the changes in symptoms between bridge and destination therapy patients as part of a prospective cohort study. Physical (dyspnea and wake disturbances) and affective symptoms (depression and anxiety) were measured before LVAD and at 1, 3, and 6 months after LVAD. Multiphase growth modeling was used to capture the 2 major phases of change: initial improvements between preimplant and 1 month after LVAD and subsequent improvements between 1 and 6 months after LVAD. The sample included 64 bridge and 22 destination therapy patients as the preimplant strategy. Destination patients had worse preimplant dyspnea and wake disturbances, and they experienced greater initial improvements in these symptoms compared with bridge patients (all P .05). Destination patients had worse preimplant depression (P = .042) but experienced similar initial and subsequent improvements in depression in response to LVAD compared with bridge patients (both P > .05). Destination patients had similar preimplant anxiety (P = .279) but experienced less initial and greater subsequent improvements in anxiety after LVAD compared with bridge patients (both P < .05). There are many differences in the magnitude and timing of change in symptom responses to LVAD between bridge and destination therapy patients. Detailed information on changes in specific symptoms may better inform shared decision-making regarding LVAD.

  5. Relationship between Fibrosis and Ventricular Arrhythmias in Chagas Heart Disease Without Ventricular Dysfunction

    Energy Technology Data Exchange (ETDEWEB)

    Tassi, Eduardo Marinho, E-mail: etassi@ibest.com.br [Instituto de Cardiologia Edson Saad - Universidade Federal do Rio de Janeiro (UFRJ), Rio de Janeiro, RJ (Brazil); Continentino, Marcelo Abramoff [Hospital Frei Galvão, Guaratinguetá, SP (Brazil); Nascimento, Emília Matos do; Pereira, Basílio de Bragança [Instituto de Cardiologia Edson Saad - Universidade Federal do Rio de Janeiro (UFRJ), Rio de Janeiro, RJ (Brazil); Coppe - Instituto Alberto Luiz Coimbra de Pós-Graduação e Pesquisa de Engenharia - UFRJ, Rio de Janeiro, RJ (Brazil); Pedrosa, Roberto Coury [Instituto de Cardiologia Edson Saad - Universidade Federal do Rio de Janeiro (UFRJ), Rio de Janeiro, RJ (Brazil)

    2014-05-15

    Patients with Chagas disease and segmental wall motion abnormality (SWMA) have worse prognosis independent of left ventricular ejection fraction (LVEF). Cardiac magnetic resonance (CMR) is currently the best method to detect SWMA and to assess fibrosis. To quantify fibrosis by using late gadolinium enhancement CMR in patients with Chagas disease and preserved or minimally impaired ventricular function (> 45%), and to detect patterns of dependence between fibrosis, SWMA and LVEF in the presence of ventricular arrhythmia. Electrocardiogram, treadmill exercise test, Holter and CMR were carried out in 61 patients, who were divided into three groups as follows: (1) normal electrocardiogram and CMR without SWMA; (2) abnormal electrocardiogram and CMR without SWMA; (3) CMR with SWMA independently of electrocardiogram. The number of patients with ventricular arrhythmia in relation to the total of patients, the percentage of fibrosis, and the LVEF were, respectively: Group 1, 4/26, 0.74% and 74.34%; Group 2, 4/16, 3.96% and 68.5%; and Group 3, 11/19, 14.07% and 55.59%. Ventricular arrhythmia was found in 31.1% of the patients. Those with and without ventricular arrhythmia had mean LVEF of 59.87% and 70.18%, respectively, and fibrosis percentage of 11.03% and 3.01%, respectively. Of the variables SWMA, groups, age, LVEF and fibrosis, only the latter was significant for the presence of ventricular arrhythmia, with a cutoff point of 11.78% for fibrosis mass (p < 0.001). Even in patients with Chagas disease and preserved or minimally impaired ventricular function, electrical instability can be present. Regarding the presence of ventricular arrhythmia, fibrosis is the most important variable, its amount being proportional to the complexity of the groups.

  6. Relationship between Fibrosis and Ventricular Arrhythmias in Chagas Heart Disease Without Ventricular Dysfunction

    International Nuclear Information System (INIS)

    Tassi, Eduardo Marinho; Continentino, Marcelo Abramoff; Nascimento, Emília Matos do; Pereira, Basílio de Bragança; Pedrosa, Roberto Coury

    2014-01-01

    Patients with Chagas disease and segmental wall motion abnormality (SWMA) have worse prognosis independent of left ventricular ejection fraction (LVEF). Cardiac magnetic resonance (CMR) is currently the best method to detect SWMA and to assess fibrosis. To quantify fibrosis by using late gadolinium enhancement CMR in patients with Chagas disease and preserved or minimally impaired ventricular function (> 45%), and to detect patterns of dependence between fibrosis, SWMA and LVEF in the presence of ventricular arrhythmia. Electrocardiogram, treadmill exercise test, Holter and CMR were carried out in 61 patients, who were divided into three groups as follows: (1) normal electrocardiogram and CMR without SWMA; (2) abnormal electrocardiogram and CMR without SWMA; (3) CMR with SWMA independently of electrocardiogram. The number of patients with ventricular arrhythmia in relation to the total of patients, the percentage of fibrosis, and the LVEF were, respectively: Group 1, 4/26, 0.74% and 74.34%; Group 2, 4/16, 3.96% and 68.5%; and Group 3, 11/19, 14.07% and 55.59%. Ventricular arrhythmia was found in 31.1% of the patients. Those with and without ventricular arrhythmia had mean LVEF of 59.87% and 70.18%, respectively, and fibrosis percentage of 11.03% and 3.01%, respectively. Of the variables SWMA, groups, age, LVEF and fibrosis, only the latter was significant for the presence of ventricular arrhythmia, with a cutoff point of 11.78% for fibrosis mass (p < 0.001). Even in patients with Chagas disease and preserved or minimally impaired ventricular function, electrical instability can be present. Regarding the presence of ventricular arrhythmia, fibrosis is the most important variable, its amount being proportional to the complexity of the groups

  7. Hemodynamic Effects of Ventricular Assist Device Implantation on Norwood, Glenn, and Fontan Circulation: A Simulation Study.

    Science.gov (United States)

    Di Molfetta, Arianna; Amodeo, Antonio; Gagliardi, Maria G; Trivella, Maria G; Fresiello, Libera; Filippelli, Sergio; Toscano, Alessandra; Ferrari, Gianfranco

    2016-01-01

    The growing population of failing single-ventricle (SV) patients might benefit from ventricular assist device (VAD) support as a bridge to heart transplantation. However, the documented experience is limited to isolated case reports. Considering the complex and different physiopathology of Norwood, Glenn, and Fontan patients and the lack of established experience, the aim of this work is to realize and test a lumped parameter model of the cardiovascular system able to simulate SV hemodynamics and VAD implantation effects to support clinical decision. Hemodynamic and echocardiographic data of 30 SV patients (10 Norwood, 10 Glenn, and 10 Fontan) were retrospectively collected and used to simulate patients' baseline. Then, the effects of VAD implantation were simulated. Simulation results suggest that the implantation of VAD: (i) increases the cardiac output and the mean arterial systemic pressure in all the three palliation conditions (Norwood 77.2 and 19.7%, Glenn 38.6 and 32.2%, and Fontan 17.2 and 14.2%); (ii) decreases the SV external work (Norwood 55%, Glenn 35.6%, and Fontan 41%); (iii) decreases the pressure pulsatility index (Norwood 65.2%, Glenn 81.3%, and Fontan 64.8%); (iv) increases the pulmonary arterial pressure in particular in the Norwood circulation (Norwood 39.7%, Glenn 12.1% and Fontan 3%); and (v) decreases the atrial pressure (Norwood 2%, Glenn 10.6%, and Fontan 8.6%). Finally, the VAD work is lower in the Norwood circulation (30.4 mL·mm Hg) in comparison with Fontan (40.3 mL·mm Hg) and to Glenn (64.5 mL·mm Hg) circulations. The use of VAD in SV physiology could be helpful to bridge patients to heart transplantations by increasing the CO and unloading the SV with a decrement of the atrial pressure and the SV external work. The regulation of the pulmonary flow is challenging because the Pap is increased by the presence of VAD. The hemodynamic changes are different in the different SV palliation step. The use of numerical models

  8. Exercise therapy for an older patient with left ventricular assist device.

    Science.gov (United States)

    Park, Won Hah; Seo, Yong Gon; Sung, Ji Dong

    2014-06-01

    A left ventricular assist device (LVAD) is a mechanical circulation support implanted for patients with end-stage heart failure. It may be used either as a bridge to cardiac transplantation or as a destination therapy. The health of a 75-year-old man with a medical history of systolic heart failure worsened. Therefore, he was recommended to have implanted a LVAD (Thoratec Corp.) as a destination therapy. After the surgery, he was enrolled in patient cardiac rehabilitation for the improvement of dyspnea and exercise capacity. In results, there is an improvement on his exercise capacity and quality of life. For the first time in Korea, we reported a benefit of exercise therapy after being implanted with a LVAD.

  9. Heart rhythm at the time of death documented by an implantable loop recorder

    DEFF Research Database (Denmark)

    Gang, Uffe Jakob Ortved; Jøns, Christian; Jørgensen, Rikke Mørch

    2009-01-01

    Aims The aims of this study were to describe arrhythmias documented with an implantable loop recorder (ILR) in post-acute myocardial infarction (AMI) patients with left ventricular dysfunction at the time of death and to establish the correlation to mode of death. Methods and results Post......-mortem ILR device interrogations were analysed from patients dying in the CARISMA study. Mode of death was classified by a modified CAST classification. Twenty-six patients died with an implanted ILR. Of these, 16 had an electrocardiogram recorded at the time of death. Ventricular tachycardia (VT......)/ventricular fibrillation (VF) was terminal rhythm in eight patients and bradyarrhythmias were observed in another eight patients. Of the deaths with peri-mortem recordings, seven were classified as sudden cardiac death (SCD). In six of these, VF was documented at the time of death. Six monitored deaths were classified...

  10. Anuloplastia de homoenxerto pulmonar criopreservado com anel de Delrin na atresia pulmonar com comunicação interventricular Annuloplasty of cryopreserved pulmonary homograft with Delrin stent in pulmonary atresia with ventricular septal defect

    Directory of Open Access Journals (Sweden)

    Ulisses Alexandre Croti

    2007-05-01

    Full Text Available Criança de seis anos portadora de atresia pulmonar com comunicação interventricular, submetida a correção total com um ano, empregando monoválvula de pericárdio bovino na reconstrução da via de saída do ventrículo direito. Evoluiu com importante regurgitação valvar pulmonar (RVP e disfunção do ventrículo direito. Na reoperação foi implantado homoenxerto pulmonar criopreservado (HPC com anuloplastia, utilizando anel de Delrin com o intuito de evitar distorção geométrica do conduto. Após dois anos, o ecocardiograma, semelhante ao pós-operatório imediato, demonstra RVP discreta e função ventricular direita normal, sugerindo que essa manobra pode ser utilizada como coadjuvante para otimizar o resultado do implante do HPC.A six-year-old child was suffering from pulmonary atresia with ventricular septal defect after a total correction at 1 year of age using a bovine pericardial monocusp valve in the reconstruction of the right ventricle outflow tract. The infant evolved with significant pulmonary valve regurgitation (PVR and right ventricle dysfunction. On reoperation, a cryopreserved pulmonary homograft (CPH was implanted with annuloplasty utilizing a Delrin ring with the aim of avoiding geometric distortion of the vessel. After two years, an echocardiogram proved a similar state to the immediate postoperative period with slight pulmonary valve regurgitation and normal right ventricular function suggesting that this maneuver may be used as coadjuvant treatment to optimize the result of CPH implantation.

  11. The evolutionary landscape of intergenic trans-splicing events in insects

    Science.gov (United States)

    Kong, Yimeng; Zhou, Hongxia; Yu, Yao; Chen, Longxian; Hao, Pei; Li, Xuan

    2015-01-01

    To explore the landscape of intergenic trans-splicing events and characterize their functions and evolutionary dynamics, we conduct a mega-data study of a phylogeny containing eight species across five orders of class Insecta, a model system spanning 400 million years of evolution. A total of 1,627 trans-splicing events involving 2,199 genes are identified, accounting for 1.58% of the total genes. Homology analysis reveals that mod(mdg4)-like trans-splicing is the only conserved event that is consistently observed in multiple species across two orders, which represents a unique case of functional diversification involving trans-splicing. Thus, evolutionarily its potential for generating proteins with novel function is not broadly utilized by insects. Furthermore, 146 non-mod trans-spliced transcripts are found to resemble canonical genes from different species. Trans-splicing preserving the function of ‘breakup' genes may serve as a general mechanism for relaxing the constraints on gene structure, with profound implications for the evolution of genes and genomes. PMID:26521696

  12. Diastolic And Systolic Right Ventricular Dysfunction Precedes Left Ventricular Dysfunction In Patients Paced From Right Ventricular Apex

    Directory of Open Access Journals (Sweden)

    Dwivedi SK

    2006-07-01

    Full Text Available Background: Cardiac dysfunction after right ventricular (RV apical pacing is well known but its extent, time frame of appearance and individual effect on left ventricular (LV, RV systolic and diastolic parameters has not evaluated in a systematic fashion. Methods: Patients with symptomatic bradycardia and ACC-AHA Class I indication for permanent pacemaker implantation (PPI were implanted a single chamber (VVI pacemaker. They were followed prospectively by echocardiographic examination which was done at baseline, 1 week, 1 month and 6 months after implantation. Parameters observed were chamber dimensions (M-line, chamber volumes, cardiac output (modified Simpson's method, systolic functions (ejection fraction, pre-ejection period, ejection time and ratio and diastolic functions( isovolumic relaxation time & deceleration time of left and right heart. Results: Forty eight consecutive patients (mean age 65.6±11.8 yrs, 66.7% males, mean EF 61.82±10.36% implanted a VVI pacemaker were enrolled in this study. The first significant change to appear in cardiac function after VVI pacing was in diastolic properties of RV as shown by increase in RV isovolumic relaxation time (IVRT from 65.89±15.93 to 76.58±17.00 ms,(p<0.001 at 1week and RV deceleration time (DT from 133.84±38.13 to 153.09±31.41 ms, (p=0.02 at 1 month. Increase in RV internal dimension (RVID from 1.26±0.41 to 1.44±0.44, (p<0.05 was also noticed at 1 week. The LV diastolic parameters were significantly altered after 1 month with increase in LV-IVRT from 92.36±21.47 to 117.24±27.21ms, (p<0.001 and increase in LV DT from 147.56±31.84 to 189.27±28.49ms,(p<0.01. This was followed by LV systolic abnormality which appeared at 6 months with an increase in LVPEP from 100.33±14.43 to 118.41±21.34ms, (p<0.001 and increase in LVPEP/LVET ratio from 0.34±0.46 to 0.44±0.10, (p<0.001]. The reduction in LV EF was manifested at 6 months falling from 61.82±10.36% to52.52±12.11%, (p<0

  13. Electrophysiology Catheter-Facilitated coronary sinus cannulation and implantation of cardiac resynchronization therapy systems

    Directory of Open Access Journals (Sweden)

    Antonis S. Manolis, MD, FESC, FACC, FHRS

    2018-01-01

    Full Text Available Background: Cardiac resynchronization therapy (CRT device implantation is hampered by difficult placement of the left ventricular (LV lead. We have routinely used a steerable electrophysiology catheter to guide coronary sinus (CS cannulation and facilitate LV lead positioning. The aim of this prospective study is to present our results with this approach in 138 consecutive patients receiving a CRT device over 10 years. Methods: The study included 120 men and 18 women, aged 64.8±11.4 years, with coronary disease (n=63, cardiomyopathy (n=72, or other disease (n=3, and mean ejection fraction of 24.5±4.5%. Devices were implanted for refractory heart failure and dyssynchrony, all but 2 in the presence of left bundle branch block. Implanted devices included biventricular pacemakers (CRT-P (n=33 and cardioverter defibrillators (CRT-D (n=105. Results: Using the electrophysiology catheter, the CS could be engaged in 134 (97.1% patients. In 4 patients failing CS cannulation, a dual-chamber device was implanted in 2, and bifocal right ventricular pacing was effected in 2. Bifocal (n=2 or conventional (n=1 systems were implanted in another 3 patients, in whom the LV lead got dislodged (n=2 or removed because of local dissection (n=1. Thus, finally, a CRT system was successfully established in 131 (94.9% patients. There were 3 patients with CS dissection, of whom 1 was complicated by cardiac tamponade managed with pericardiocentesis. There were no perioperative deaths. During follow-up (31.0±21.2 months, clinical improvement was reported by 108 (82.4% patients. Conclusion: Routine use of an electrophysiology catheter greatly facilitated CS cannulation and successful LV lead placement in ∼95% of patients undergoing CRT system implantation. Keywords: heart failure, cardiac resynchronization therapy, implantable cardioverter defibrillator, coronary sinus, left ventricular lead

  14. Use of Ventricular Assist Device in Univentricular Physiology: The Role of Lumped Parameter Models.

    Science.gov (United States)

    Di Molfetta, Arianna; Ferrari, Gianfranco; Filippelli, Sergio; Fresiello, Libera; Iacobelli, Roberta; Gagliardi, Maria G; Amodeo, Antonio

    2016-05-01

    Failing single-ventricle (SV) patients might benefit from ventricular assist devices (VADs) as a bridge to heart transplantation. Considering the complex physiopathology of SV patients and the lack of established experience, the aim of this work was to realize and test a lumped parameter model of the cardiovascular system, able to simulate SV hemodynamics and VAD implantation effects. Data of 30 SV patients (10 Norwood, 10 Glenn, and 10 Fontan) were retrospectively collected and used to simulate patients' baseline. Then, the effects of VAD implantation were simulated. Additionally, both the effects of ventricular assistance and cavopulmonary assistance were simulated in different pathologic conditions on Fontan patients, including systolic dysfunction, diastolic dysfunction, and pulmonary vascular resistance increment. The model can reproduce patients' baseline well. Simulation results suggest that the implantation of VAD: (i) increases the cardiac output (CO) in all the three palliation conditions (Norwood 77.2%, Glenn 38.6%, and Fontan 17.2%); (ii) decreases the SV external work (SVEW) (Norwood 55%, Glenn 35.6%, and Fontan 41%); (iii) increases the mean pulmonary arterial pressure (Pap) (Norwood 39.7%, Glenn 12.1%, and Fontan 3%). In Fontan circulation, with systolic dysfunction, the left VAD (LVAD) increases CO (35%), while the right VAD (RVAD) determines a decrement of inferior vena cava pressure (Pvci) (39%) with 34% increment of CO. With diastolic dysfunction, the LVAD increases CO (42%) and the RVAD decreases the Pvci. With pulmonary vascular resistance increment, the RVAD allows the highest CO (50%) increment with the highest decrement of Pvci (53%). The single ventricular external work (SVEW) increases (decreases) increasing the VAD speed in cavopulmonary (ventricular) assistance. Numeric models could be helpful in this challenging and innovative field to support patients and VAD selection to optimize the clinical outcome and personalize the therapy

  15. Exacerbation of electrical storm subsequent to implantation of a right vagal stimulator.

    Science.gov (United States)

    Shalaby, Alaa A; El-Saed, Aiman; Nemec, Jan; Moossy, John J; Balzer, Jeffrey R

    2007-12-01

    A patient with advanced ischemic cardiomyopathy underwent implantation of a vagal stimulator in an attempt to control recurrent drug refractory ventricular arrhythmia. Electrical storm was exacerbated after the implant and continued after neurostimulation was discontinued. The report aims to provide a cautionary note to application of vagal stimulation for control of cardiac arrhythmia.

  16. Transcatheter Pulmonary Valve Replacement for Right Ventricular Outflow Tract Conduit Dysfunction After the Ross Procedure

    DEFF Research Database (Denmark)

    Gillespie, Matthew J; McElhinney, Doff B; Kreutzer, Jacqueline

    2015-01-01

    BACKGROUND: Right ventricular outflow tract (RVOT) conduit dysfunction is a limitation of the Ross procedure. Transcatheter pulmonary valve replacement (TPVR) could alter the impact of conduit dysfunction and the risk-benefit balance for the Ross procedure. METHODS: Retrospective review of databa......BACKGROUND: Right ventricular outflow tract (RVOT) conduit dysfunction is a limitation of the Ross procedure. Transcatheter pulmonary valve replacement (TPVR) could alter the impact of conduit dysfunction and the risk-benefit balance for the Ross procedure. METHODS: Retrospective review....... Of these, 56 (84%) received a Melody valve; in 5 of the 11 patients who did not, the implant was aborted due to concern for coronary artery compression, and 1 implanted patient required emergent surgery for left coronary compression. The RVOT gradient decreased from a median 38 mm Hg to 13.5 mm Hg (p

  17. Skin Sodium Concentration Correlates with Left Ventricular Hypertrophy in CKD.

    Science.gov (United States)

    Schneider, Markus P; Raff, Ulrike; Kopp, Christoph; Scheppach, Johannes B; Toncar, Sebastian; Wanner, Christoph; Schlieper, Georg; Saritas, Turgay; Floege, Jürgen; Schmid, Matthias; Birukov, Anna; Dahlmann, Anke; Linz, Peter; Janka, Rolf; Uder, Michael; Schmieder, Roland E; Titze, Jens M; Eckardt, Kai-Uwe

    2017-06-01

    The pathogenesis of left ventricular hypertrophy in patients with CKD is incompletely understood. Sodium intake, which is usually assessed by measuring urinary sodium excretion, has been inconsistently linked with left ventricular hypertrophy. However, tissues such as skin and muscle may store sodium. Using 23 sodium-magnetic resonance imaging, a technique recently developed for the assessment of tissue sodium content in humans, we determined skin sodium content at the level of the calf in 99 patients with mild to moderate CKD (42 women; median [range] age, 65 [23-78] years). We also assessed total body overhydration (bioimpedance spectroscopy), 24-hour BP, and left ventricular mass (cardiac magnetic resonance imaging). Skin sodium content, but not total body overhydration, correlated with systolic BP ( r =0.33, P =0.002). Moreover, skin sodium content correlated more strongly than total body overhydration did with left ventricular mass ( r =0.56, P skin sodium content is a strong explanatory variable for left ventricular mass, unaffected by BP and total body overhydration. In conclusion, we found skin sodium content to be closely linked to left ventricular mass in patients with CKD. Interventions that reduce skin sodium content might improve cardiovascular outcomes in these patients. Copyright © 2017 by the American Society of Nephrology.

  18. Acquired tricuspid valve stenosis associated with two ventricular endocardial pacing leads in a dog.

    Science.gov (United States)

    Tompkins, Emily; Dulake, Michelle I; Ghaffari, Shadie; Nakamura, Reid K

    2015-01-01

    Acquired tricuspid valve stenosis (TVS) is a rare complication of endocardial pacing lead implantation in humans that has only been described once previously in the veterinary literature in a dog with excessive lead redundancy. A 12 yr old terrier presented with right-sided congestive heart failure 6 mo after implantation of a second ventricular endocardial pacing lead. The second lead was placed due to malfunction of the first lead, which demonstrated abnormally low impedance. Transthoracic echocardiography identified hyperechoic tissue associated with the pacing leads as they crossed the tricuspid valve annulus as well as a stenotic tricuspid inflow pattern via spectral Doppler interrogation. Medical management was ultimately unsuccessful and the dog was euthanized 6 wk after TVS was diagnosed. The authors report the first canine case of acquired TVS associated with two ventricular endocardial pacing leads.

  19. Shock whilst gardening--implantable defibrillators & lawn mowers.

    Science.gov (United States)

    Von Olshausen, G; Lennerz, C; Grebmer, C; Pavaci, H; Kolb, C

    2014-02-01

    Electromagnetic interference with implantable cardioverter defibrillators (ICDs) can cause inappropriate shock delivery or temporary inhibition of ICD functions. We present a case of electromagnetic interference between a lawn mower and an ICD resulting in an inappropriate discharge of the device due to erroneous detection of ventricular fibrillation.

  20. Long-term prospective outcomes after minimally invasive trans-iliac sacroiliac joint fusion using triangular titanium implants.

    Science.gov (United States)

    Darr, Emily; Meyer, S Craig; Whang, Peter G; Kovalsky, Don; Frank, Clay; Lockstadt, Harry; Limoni, Robert; Redmond, Andy; Ploska, Philip; Oh, Michael Y; Cher, Daniel; Chowdhary, Abhineet

    2018-01-01

    Minimally invasive sacroiliac joint fusion (SIJF) has become an increasingly accepted surgical option for chronic sacroiliac (SI) joint dysfunction, a prevalent cause of unremitting low back/buttock pain. The objective of this study was to report clinical and functional outcomes of SIJF using triangular titanium implants (TTI) in the treatment of chronic SI joint dysfunction due to degenerative sacroiliitis or sacroiliac joint (SIJ) disruption at 3 years postoperatively. A total of 103 subjects with SIJ dysfunction at 12 centers were treated with TTI in two prospective clinical trials (NCT01640353 and NCT01681004) and enrolled in this long-term follow-up study (NCT02270203). Subjects were evaluated in study clinics at study start and again at 3, 4, and 5 years. Mean (SD) preoperative SIJ pain score was 81.5, and mean preoperative Oswestry Disability Index (ODI) was 56.3. At 3 years, mean pain SIJ pain score decreased to 26.2 (a 55-point improvement from baseline, p <0.0001). At 3 years, mean ODI was 28.2 (a 28-point improvement from baseline, p <0.0001). In all, 82% of subjects were very satisfied with the procedure at 3 years. EuroQol-5D (EQ-5D) time trade-off index improved by 0.30 points ( p <0.0001). No adverse events definitely related to the study device or procedure were reported; one subject underwent revision surgery at year 3.7. SIJ pain contralateral to the originally treated side occurred in 15 subjects of whom four underwent contralateral SIJF. The proportion of subjects who were employed outside the home full- or part-time at 3 years decreased somewhat from baseline ( p =0.1814), and the proportion of subjects who would have the procedure again was lower at 3 years compared to earlier time points. In long-term (3-year) follow-up, minimally invasive trans-iliac SIJF with TTI was associated with improved pain, disability, and quality of life with relatively high satisfaction rates. Level II. SIJF with TTI.

  1. Unconstrained tripolar implants for primary total hip arthroplasty in patients at risk for dislocation.

    Science.gov (United States)

    Guyen, Olivier; Pibarot, Vincent; Vaz, Gualter; Chevillotte, Christophe; Carret, Jean-Paul; Bejui-Hugues, Jacques

    2007-09-01

    We performed a retrospective study on 167 primary total hip arthroplasty (THA) procedures in 163 patients at high risk for instability to assess the reliability of unconstrained tripolar implants (press-fit outer metal shell articulating a bipolar polyethylene component) in preventing dislocations. Eighty-four percent of the patients had at least 2 risk factors for dislocation. The mean follow-up length was 40.2 months. No dislocation was observed. Harris hip scores improved significantly. Six hips were revised, and no aseptic loosening of the cup was observed. The tripolar implant was extremely successful in achieving stability. However, because of the current lack of data documenting polyethylene wear at additional bearing, the routine use of tripolar implants in primary THA is discouraged and should be considered at the present time only for selected patients at high risk for dislocation and with limited activities.

  2. Extraocular surgery for implantation of an active subretinal visual prosthesis with external connections: feasibility and outcome in seven patients.

    Science.gov (United States)

    Besch, D; Sachs, H; Szurman, P; Gülicher, D; Wilke, R; Reinert, S; Zrenner, E; Bartz-Schmidt, K U; Gekeler, F

    2008-10-01

    Due to low energy levels in microphotodiode-based subretinal visual prostheses, an external power supply is mandatory. We report on the surgical feasibility and the functional outcome of the extraocular part of an approach to connect a subretinal prosthesis to an extracorporeal connector in the retro-auricular space via a trans-scleral, transchoroidal cable. Seven volunteers with retinitis pigmentosa received an active subretinal implant; energy was supplied by gold wires on a trans-sclerally, transchoroidally implanted polyimide foil leading to the lateral orbital rim where it was fixated and connected to a silicone cable. The cable was implanted subperiostally beneath the temporal muscle using a trocar to the retro-auricular space where it penetrated the skin for connection to a stimulator. To avoid subretinal movement of the implant, three tension relief points have been introduced. All implantations were performed as planned without complications, and no serious adverse events occurred in the postoperative period. Fixation of the implants was stable throughout the entire study duration of 4 weeks; permanent skin penetration proved to be uncomplicated. Motility was minimally restricted in downgaze and ab-/adduction. Explantation was uneventful. The above-described procedure provides a method for stable fixation of a subretinal device with a trans-scleral, transchoroidal cable connection to an extracorporeal connector.

  3. Nonischemic Left Ventricular Scar as a Substrate of Life-Threatening Ventricular Arrhythmias and Sudden Cardiac Death in Competitive Athletes.

    Science.gov (United States)

    Zorzi, Alessandro; Perazzolo Marra, Martina; Rigato, Ilaria; De Lazzari, Manuel; Susana, Angela; Niero, Alice; Pilichou, Kalliopi; Migliore, Federico; Rizzo, Stefania; Giorgi, Benedetta; De Conti, Giorgio; Sarto, Patrizio; Serratosa, Luis; Patrizi, Giampiero; De Maria, Elia; Pelliccia, Antonio; Basso, Cristina; Schiavon, Maurizio; Bauce, Barbara; Iliceto, Sabino; Thiene, Gaetano; Corrado, Domenico

    2016-07-01

    The clinical profile and arrhythmic outcome of competitive athletes with isolated nonischemic left ventricular (LV) scar as evidenced by contrast-enhanced cardiac magnetic resonance remain to be elucidated. We compared 35 athletes (80% men, age: 14-48 years) with ventricular arrhythmias and isolated LV subepicardial/midmyocardial late gadolinium enhancement (LGE) on contrast-enhanced cardiac magnetic resonance (group A) with 38 athletes with ventricular arrhythmias and no LGE (group B) and 40 healthy control athletes (group C). A stria LGE pattern with subepicardial/midmyocardial distribution, mostly involving the lateral LV wall, was found in 27 (77%) of group A versus 0 controls (group C; P<0.001), whereas a spotty pattern of LGE localized at the junction of the right ventricle to the septum was respectively observed in 11 (31%) versus 10 (25%; P=0.52). All athletes with stria pattern showed ventricular arrhythmias with a predominant right bundle branch block morphology, 13 of 27 (48%) showed ECG repolarization abnormalities, and 5 of 27 (19%) showed echocardiographic hypokinesis of the lateral LV wall. The majority of athletes with no or spotty LGE pattern had ventricular arrhythmias with a predominant left bundle branch block morphology and no ECG or echocardiographic abnormalities. During a follow-up of 38±25 months, 6 of 27 (22%) athletes with stria pattern experienced malignant arrhythmic events such as appropriate implantable cardiac defibrillator shock (n=4), sustained ventricular tachycardia (n=1), or sudden death (n=1), compared with none of athletes with no or LGE spotty pattern and controls. Isolated nonischemic LV LGE with a stria pattern may be associated with life-threatening arrhythmias and sudden death in the athlete. Because of its subepicardial/midmyocardial location, LV scar is often not detected by echocardiography. © 2016 The Authors.

  4. Median Sternotomy or Right Thoracotomy Techniques for Total Artificial Heart Implantation in Calves.

    Science.gov (United States)

    Karimov, Jamshid H; Moazami, Nader; Sunagawa, Gengo; Kobayashi, Mariko; Byram, Nicole; Sale, Shiva; Such, Kimberly A; Horvath, David J; Golding, Leonard A R; Fukamachi, Kiyotaka

    2016-10-01

    The choice of optimal operative access technique for mechanical circulatory support device implantation ensures successful postoperative outcomes. In this study, we retrospectively evaluated the median sternotomy and lateral thoracotomy incisions for placement of the Cleveland Clinic continuous-flow total artificial heart (CFTAH) in a bovine model. The CFTAH was implanted in 17 calves (Jersey calves; weight range, 77.0-93.9 kg) through a median sternotomy (n = 9) or right thoracotomy (n = 8) for elective chronic implantation periods of 14, 30, or 90 days. Similar preoperative preparation, surgical techniques, and postoperative care were employed. Implantation of the CFTAH was successfully performed in all cases. Both methods provided excellent surgical field visualization. After device connection, however, the median sternotomy approach provided better visualization of the anastomoses and surgical lines for hemostasis confirmation and repair due to easier device displacement, which is severely limited following right thoracotomy. All four animals sacrificed after completion of the planned durations (up to 90 days) were operated through full median sternotomy. Our data demonstrate that both approaches provide excellent initial field visualization. Full median sternotomy provides larger viewing angles at the anastomotic suture line after device connection to inflow and outflow ports. Copyright © 2015 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  5. Spectroscopic and density functional theory studies of trans-3-(trans-4-imidazolyl)acrylic acid.

    Science.gov (United States)

    Arjunan, V; Remya, P; Sathish, U; Rani, T; Mohan, S

    2014-08-14

    The structural parameters, thermodynamic properties and vibrational frequencies of the optimised geometry of trans-3-(trans-4-imidazolyl)acrylic acid have been determined from B3LYP methods with 6-311++G(**) and cc-pVTZ basis sets. The effects of substituents (acrylyl group) on the imidazole vibrational frequencies are analysed. The vibrational frequencies of the fundamental modes of trans-3-(trans-4-imidazolyl)acrylic acid have been precisely assigned and analysed and the theoretical results are compared with the experimental vibrations. (1)H and (13)C NMR isotropic chemical shifts are calculated and the assignments made are compared with the experimental values. The energies of important MO's of the compound are also determined from DFT method. The total electron density and electrostatic potential of the compound are determined by natural bond orbital analysis. Various reactivity and selectivity descriptors such as chemical hardness, chemical potential, softness, electrophilicity, nucleophilicity and the appropriate local quantities employing natural population analysis (NPA) are calculated. Copyright © 2014 Elsevier B.V. All rights reserved.

  6. Implante transapical de valva aórtica: resultados de uma nova prótese brasileira Transapical aortic valve implantation: results of a brazilian prosthesis

    Directory of Open Access Journals (Sweden)

    Diego Felipe Gaia

    2010-09-01

    Full Text Available OBJETIVO: A troca valvar aórtica é procedimento rotineiro com risco aceitável. Em alguns casos, a mortalidade é elevada, levando à contraindicação do procedimento, apesar dos sintomas. O implante minimamente invasivo transcateter de valva aórtica parece ser uma alternativa, reduzindo a morbi-mortalidade. O objetivo deste estudo foi o desenvolvimento e implante de nova prótese para implante transcateter. MÉTODOS: Após desenvolvimento em animais, uma prótese transcateter, balão-expansível foi utilizada em 14 casos de alto risco. O EuroSCORE médio foi de 43,7%. Quatro pacientes apresentavam disfunção de biopróteses e o restante, estenose aórtica calcificada. Todos os pacientes eram sintomáticos. Os procedimentos foram realizados em ambiente cirúrgico híbrido, sob controle ecocardiográfico e fluoroscópico. Com o uso de minitoracotomia esquerda, as próteses foram implantadas através do ápice ventricular, sob estimulação ventricular de alta frequência ou choque hemorrágico controlado, após valvoplastia aórtica. Foram realizados controles clínicos e ecocardiográficos seriados. RESULTADOS: A correta liberação da prótese foi possível em 13 casos. Uma conversão ocorreu. Não houve mortalidade operatória. O gradiente de pico médio pós-implante foi de 25 mmHg. A fração de ejeção apresentou aumento significativo após o 7º pós-operatório. Insuficiência aórtica residual não significativa esteve presente em 71% dos casos, nenhuma significativa. Não ocorreu complicação vascular periférica. Não houve necessidade de marcapasso definitivo. Um caso de acidente vascular cerebral ocorreu. A mortalidade geral foi de 42%. CONCLUSÃO: O implante transapical de valva aórtica transcateter é um procedimento possível com esta nova prótese. O comportamento hemodinâmico foi satisfatório. São necessários estudos de longo prazo e com maior poder amostral, no intuito de determinar a real eficácia e indicação do

  7. [Total cervical disk replacement--implant-specific approaches: keel implant (Prodisc-C intervertebral disk prosthesis)].

    Science.gov (United States)

    Korge, Andreas; Siepe, Christoph J; Heider, Franziska; Mayer, H Michael

    2010-11-01

    Dynamic intervertebral support of the cervical spine via an anterolateral approach using a modular artificial disk prosthesis with end-plate fixation by central keel fixation. Cervical median or mediolateral disk herniations, symptomatic cervical disk disease (SCDD) with anterior osseous, ligamentous and/or discogenic narrowing of the spinal canal. Cervical fractures, tumors, osteoporosis, arthrogenic neck pain, severe facet degeneration, increased segmental instability, ossification of posterior longitudinal ligament (OPLL), severe osteopenia, acute and chronic systemic, spinal or local infections, systemic and metabolic diseases, known implant allergy, pregnancy, severe adiposity (body mass index > 36 kg/m2), reduced patient compliance, alcohol abuse, drug abuse and dependency. Exposure of the anterior cervical spine using the minimally invasive anterolateral approach. Intervertebral fixation of retainer screws. Intervertebral diskectomy. Segmental distraction with vertebral body retainer and vertebral distractor. Removal of end-plate cartilage. Microscopically assisted decompression of spinal canal. Insertion of trial implant to determine appropriate implant size, height and position. After biplanar image intensifier control, drilling for keel preparation using drill guide and drill bit, keel-cut cleaner to remove bone material from the keel cut, radiologic control of depth of the keel cut using the corresponding position gauge. Implantation of original implant under lateral image intensifier control. Removal of implant inserter. Functional postoperative care and mobilization without external support, brace not used routinely, soft brace possible for 14 days due to postoperative pain syndromes. Implantation of 100 cervical Prodisc-C disk prostheses in 78 patients (average age 48 years) at a single center. Clinical and radiologic follow-up 24 months postoperatively. Significant improvement based on visual analog scale and Neck Disability Index. Radiologic

  8. Use of Cardiac Computed Tomography for Ventricular Volumetry in Late Postoperative Patients with Tetralogy of Fallot

    Directory of Open Access Journals (Sweden)

    Ho Jin Kim

    2017-04-01

    Full Text Available Background: Cardiac computed tomography (CT has emerged as an alternative to magnetic resonance imaging (MRI for ventricular volumetry. However, the clinical use of cardiac CT requires external validation. Methods: Both cardiac CT and MRI were performed prior to pulmonary valve implantation (PVI in 11 patients (median age, 19 years who had undergone total correction of tetralogy of Fallot during infancy. The simplified contouring method (MRI and semiautomatic 3-dimensional region-growing method (CT were used to measure ventricular volumes. Results: All volumetric indices measured by CT and MRI generally correlated well with each other, except for the left ventricular end-systolic volume index (LV-ESVI, which showed the following correlations with the other indices: the right ventricular end-diastolic volume index (RV-EDVI (r=0.88, p<0.001, the right ventricular end-systolic volume index (RV-ESVI (r=0.84, p=0.001, the left ventricular end-diastolic volume index (LV-EDVI (r=0.90, p=0.001, and the LV-ESVI (r=0.55, p=0.079. While the EDVIs measured by CT were significantly larger than those measured by MRI (median RV-EDVI: 197 mL/m 2 vs. 175 mL/m 2 , p=0.008; median LV-EDVI: 94 mL/m 2 vs. 92 mL/m 2 , p=0.026, no significant differences were found for the RV-ESVI or LV-ESVI. Conclusion: The EDVIs measured by cardiac CT were greater than those measured by MRI, whereas the ESVIs measured by CT and MRI were comparable. The volumetric characteristics of these 2 diagnostic modalities should be taken into account when indications for late PVI after tetralogy of Fallot repair are assessed.

  9. "Rescue" ablation of electrical storm in arrhythmogenic right ventricular cardiomyopathy in pregnancy.

    Science.gov (United States)

    Stec, Sebastian; Krynski, Tomasz; Baran, Jakub; Kulakowski, Piotr

    2013-08-13

    Radiofrequency ablation (RFCA) became a treatment of choice in patients with recurrent ventricular tachycardia, ventricular fibrillation, and appropriate interventions of implanted cardioverter-defibrillator (ICD), however, electrical storm (ES) ablation in a pregnant woman has not yet been reported. We describe a case of a successful rescue ablation of recurrent ES in a 26-year-old Caucasian woman during her first pregnancy (23rd week). The arrhythmogenic right ventricular dysplasia/cardiomyopathy (ARVD/C) was diagnosed 3 years earlier and several drugs as well as 2 ablations failed to control recurrences of ventricular tachycardia. RFCA was performed on the day of the third electric storm. The use of electroanatomic mapping allowed very low X-ray exposure, and after applications in the right ventricular outflow tract, arrhythmia disappeared. Three months after ablation, a healthy girl was delivered without any complications. During twelve-month follow-up there was no recurrence of ventricular tachycardia or ICD interventions. This case documents the first successful RFCA during ES due to recurrent unstable ventricular arrhythmias in a patient with ARVD/C in pregnancy. Current guidelines recommend metoprolol, sotalol and intravenous amiodarone for prevention of recurrent ventricular tachycardia in pregnancy, however, RFCA should be considered as a therapeutic option in selected cases. The use of 3D navigating system and near zero X-ray approach is associated with minimal radiation exposure for mother and fetus as well as low risk of procedural complication.

  10. Ventricular Tachycardia in the Absence of Structural Heart Disease

    Directory of Open Access Journals (Sweden)

    Luis R. P. Scott

    2005-04-01

    Full Text Available In up to 10% of patients who present with ventricular tachycardia (VT, obvious structural heart disease is not identified. In such patients, causes of ventricular arrhythmia include right ventricular outflow tract (RVOT VT, extrasystoles, idiopathic left ventricular tachycardia (ILVT, idiopathic propranolol-sensitive VT (IPVT, catecholaminergic polymorphic VT (CPVT, Brugada syndrome, and long QT syndrome (LQTS. RVOT VT, ILVT, and IPVT are referred to as idiopathic VT and generally do not have a familial basis. RVOT VT and ILVT are monomorphic, whereas IPVT may be monomorphic or polymorphic. The idiopathic VTs are classified by the ventricle of origin, the response to pharmacologic agents, catecholamine dependence, and the specific morphologic features of the arrhythmia. CPVT, Brugada syndrome, and LQTS are inherited ion channelopathies. CPVT may present as bidirectional VT, polymorphic VT, or catecholaminergic ventricular fibrillation. Syncope and sudden death in Brugada syndrome are usually due to polymorphic VT. The characteristic arrhythmia of LQTS is torsades de pointes. Overall, patients with idiopathic VT have a better prognosis than do patients with ventricular arrhythmias and structural heart disease. Initial treatment approach is pharmacologic and radiofrequency ablation is curative in most patients. However, radiofrequency ablation is not useful in the management of inherited ion channelopathies. Prognosis for patients with VT secondary to ion channelopathies is variable. High-risk patients (recurrent syncope and sudden cardiac death survivors with inherited ion channelopathies benefit from implantable cardioverter-defibrillator placement. This paper reviews the mechanism, clinical presentation, and management of VT in the absence of structural heart disease.

  11. Left ventricular assist device exchange: the Toronto General Hospital experience.

    Science.gov (United States)

    Tsubota, Hideki; Ribeiro, Roberto V P; Billia, Filio; Cusimano, Robert J; Yau, Terrence M; Badiwala, Mitesh V; Stansfield, William E; Rao, Vivek

    2017-08-01

    As support times for left ventricular assist devices (LVADs) become longer, several complications requiring device exchange may occur. To our knowledge, this is the first Canadian report regarding implantable LVAD exchange. We retrospectively reviewed the cases of consecutive, unique patients implanted with an LVAD between June 2006 and October 2015 at Toronto General Hospital. In total, 122 patients were impanted with an LVAD during the study period. Eight patients required LVAD exchange, and 1 patient had 2 replacements (9 of 122, 7.3%). There were 7 HeartMate II (HMII), 1 HVAD and 1 DuraHeart pumps exchanged. Two of these exchanges occurred early at the time of initial implant, whereas 7 occurred late (range 8-623 d). Six exchanges were made owing to pump thrombosis. Of the 3 exchanges made for other causes, 1 HMII exchange was owing to a driveline fracture, 1 DuraHeart patient had early inflow obstruction requiring exchange to HMII at the initial implant, and the third had a suspected inflow obstruction with no evidence of thrombosis at the time of the procedure. The mean support time before exchange was 225 days, and time from exchange to transplant, death or ongoing support was 245 days. Three patients were successfully bridged to transplant, and at the time of data collection 2 were supported awaiting transplant. Three patients died after a mean duration of 394.3 days (range 78-673 d) of support postreplacement. Four cases were successfully performed using a subcostal approach. Pump thrombosis is the most common cause for LVAD exchange, which can be performed with acceptable morbidity and mortality. The subcostal approach may be the preferred procedure for an HMII exchange when indicated.

  12. Impact of Tricuspid Valve Surgery at the Time of Left Ventricular Assist Device Insertion on Postoperative Outcomes

    OpenAIRE

    Dunlay, Shannon M.; Deo, Salil V.; Park, Soon J.

    2015-01-01

    Tricuspid regurgitation (TR) is common in patients with heart failure undergoing left ventricular assist device (LVAD) implantation. Whether the TR should be surgically managed at the time of LVAD surgery is controversial.

  13. Peripherally Placed Totally Implantable Venous-access Port Systems of the Forearm: Clinical Experience in 763 Consecutive Patients

    International Nuclear Information System (INIS)

    Goltz, Jan P.; Scholl, Anne; Ritter, Christian O.; Wittenberg, Guenther; Hahn, Dietbert; Kickuth, Ralph

    2010-01-01

    The aim of this study is to evaluate the effectiveness and safety of percutaneously placed totally implantable venous-access ports (TIVAPs) of the forearm. Between January 2006 and October 2008, peripheral TIVAPs were implanted in 763 consecutive patients by ultrasound and fluoroscopic guidance. All catheters were implanted under local anesthesia and were tunneled subcutaneously. Indication, technical success, and complications were retrospectively analyzed according to Society of Interventional Radiology (SIR) criteria. Presence of antibiotic prophylaxis, periprocedurally administered drugs (e.g., sedation), and laboratory results at the time of implantation were analyzed. Maintenance during the service interval was evaluated. In total, 327,499 catheter-days were analyzed. Technical success rate was 99.3%. Reasons for initial failure of implantation were either unexpected thrombosis of the subclavian vein, expanding tumor mass of the mediastinum, or failure of peripheral venous access due to fragile vessels. Mean follow-up was 430 days. There were 115 complications observed (15.1%, 0.03 per 100 catheter-days), of which 33 (4.3%) were classified as early (within 30 days from implantation) and 82 (10.7%) as late. Catheter-related venous thrombosis was found in 65 (8.5%) of 763 (0.02 per 100 catheter-days) TIVAPs. Infections were observed in 41 (5.4%) of 763 (0.01 per 100 catheter-days) devices. Other complications observed included dislocation of the catheter tip (0.8%), occlusion (0.1%), or rupture (0.1%) of the port catheter. Dislocated catheters were corrected during a second interventional procedure. In conclusion, implantation of percutaneously placed peripheral TIVAPs shows a high technical success rate and low risk of early complications when ultrasound and fluoroscopic guidance are used. Late complications are observed three times as often as early complications.

  14. The influence of right ventricular apical pacing on left atrial volume in patients with normal left ventricular function

    Directory of Open Access Journals (Sweden)

    AR Moaref1

    2008-03-01

    Full Text Available Background: Right ventricular apical (RVA pacing has been reported to induce several deleterious effects particularly in the presence of structural heart disease but can also involve patients with normal left ventricular (LV function. Left atrial (LA enlargement is one of these effects, but the majority of studies have measured LA dimension rather than volume.Objective: The present prospective study was designed to assess the effect of RVA pacing on LA volume in patients with normal LV function.Patients and Methods: The study comprised 41 consecutive patients with LV ejection fraction ≥ 45% and LV end diastolic dimension ≤ 56 mm who underwent single-or dual- chamber pacemaker implantation in RVA and followed for LA volume measurement and pacemaker analysis at least during the ensuing 4.2 months. Results: In all, 21 patients were excluded from the study due to five spontaneous wide QRS complex (≥120msec, one recent acute coronary syndrome,one significant valvular heart disease, three pacing frequency <90%, eight death or losing follow up in three cases. In remaining 20 patients, LA volume ragned from 21 to 54 mm3 with mean of 37.3±9.7 mm3 prior to pacemaker implantation that increased to 31 to 103 mm3 (54.3±17.0 during follow-up (P<0.001.Conclusion: RVA pacing might lead to an increase in LA volume even in patients with normal LV function.

  15. The NO Regular Defibrillation testing In Cardioverter Defibrillator Implantation (NORDIC ICD) trial: concept and design of a randomized, controlled trial of intra-operative defibrillation testing during de novo defibrillator implantation.

    Science.gov (United States)

    Bänsch, Dietmar; Bonnemeier, Hendrik; Brandt, Johan; Bode, Frank; Svendsen, Jesper Hastrup; Felk, Angelika; Hauser, Tino; Wegscheider, Karl

    2015-01-01

    Although defibrillation (DF) testing is still considered a standard procedure during implantable cardioverter-defibrillator (ICD) insertion and has been an essential element of all trials that demonstrated the survival benefit of ICD therapy, there are no large randomized clinical trials demonstrating that DF testing improves clinical outcome and if the outcome would remain the same by omitting DF testing. Between February 2011 and July 2013, we randomly assigned 1077 patients to ICD implantation with (n = 540) or without (n = 537) DF testing. The intra-operative DF testing was standardized across all participating centres. After inducing a fast ventricular tachycardia (VT) with a heart rate ≥240 b.p.m. or ventricular fibrillation (VF) with a low-energy T-wave shock, DF was attempted with an initial 15 J shock. If the shock reversed the VT or VF, DF testing was considered successful and terminated. If unsuccessful, two effective 24 J shocks were administered. If DF was unsuccessful, the system was reconfigured and another DF testing was performed. An ICD shock energy of 40 J had to be programmed in all patients for treatment of spontaneous VT/VF episodes. The primary endpoint was the average efficacy of the first ICD shock for all true VT/VF episodes in each patient during follow-up. The secondary endpoints included the frequency of system revisions, total fluoroscopy, implantation time, procedural serious adverse events, and all-cause, cardiac, and arrhythmic mortality during follow-up. Home Monitoring was used in all patients to continuously monitor the system integrity, device programming and performance. The NO Regular Defibrillation testing In Cardioverter Defibrillator Implantation (NORDIC ICD) trial is one of two large prospective randomized trials assessing the effect of DF testing omission during ICD implantation. NCT01282918. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2014. For permissions please email

  16. Cardioverter-defibrillator implantation in myeloma-associated cardiac amyloidosis.

    Science.gov (United States)

    Campanile, Alfonso; Sozzi, Fabiola B; Canetta, Ciro; Danzi, Gian Battista

    2013-01-01

    A 62-year-old woman with multiple myeloma and light-chain amyloidosis with significant heart involvement developed an in-hospital cardiac arrest. After cardiopulmonary resuscitation, a stable sinus rhythm without any cerebral damage was restored, and the patient was admitted to the coronary care unit. A cardioverter-defibrillator was implanted, and it successfully intervened in two sustained ventricular tachycardia episodes and one ventricular fibrillation episode, which were recorded during hospitalization. After achieving discrete cardiac compensation, the patient was transferred to the emergency medicine department where she underwent chemotherapy for multiple myeloma. The patient died 40 days after admission from refractory heart failure. In the literature, there are studies that describe the use of cardioverter-defibrillator implantation in cardiac amyloidosis; however, at present, there is no evidence of a beneficial effect on survival with the use of this intervention. A high index of suspicion for amyloid heart disease and early diagnosis are critical to improving outcomes.

  17. Left Ventricular Dysfunction Caused by Unrecognized Surgical AV block in a Patient with a Manifest Right Free Wall Accessory Pathway

    Directory of Open Access Journals (Sweden)

    Rakesh Gopinathannair, MD, MA

    2013-05-01

    Full Text Available A 24-year-old male with Wolff-Parkinson-White syndrome developed systolic cardiomyopathy and severe heart failure following membranous ventricular septal defect repair and tricuspid valve replacement. Following successful catheter ablation of a right anterolateral accessory pathway (AP, complete AV block with junctional escape rhythm was noted. Patient subsequently underwent implantation of a biventricular ICD. Heart failure symptoms significantly improved soon after and left ventricular systolic function normalized 3 months post-procedure. In this case, surgically acquired AV block likely explains development of postoperative cardiomyopathy by facilitating ventricular activation solely via the AP and thereby increasing the degree of ventricular dyssynchrony.

  18. Patient - implant dimension mismatch in total knee arthroplasty: Is it worth worrying? An Indian scenario

    Directory of Open Access Journals (Sweden)

    Jai Thilak

    2016-01-01

    Full Text Available Background: The correct sizing of the components in both anteroposterior and mediolateral (ML dimensions is crucial for the success of a total knee arthroplasty (TKA. The size of the implants selected is based on the intraoperative measurements. The currently used TKA implants available to us are based on morphometric measurements obtained from a Western/Caucasian population. Hence, the risk of component ML mismatch is more common in Asian sub-population, as they are of a smaller built and stature. This study aims to look into the following aspects agnitude of the ML mismatch between the femoral component and the patient′s anatomical dimension, evaluation of gender variations in distal femur dimensions, and gender-wise and implant-wise correlation of ML mismatch. Materials and Methods: Intraoperatively, the distal femoral dimensions were measured using sterile calipers after removing the osteophytes and compared with the ML dimension of the implant used. ML mismatch length thus obtained is correlated with the various parameters. Results: Males showed larger distal femoral dimensions when compared to females. Males had larger ML mismatch. None of the implants used perfectly matched the patient′s anatomical dimensions. Patients with larger mismatch had lower scorings at 2 years postoperative followup. Conclusion: Implant manufacturers need to design more options of femoral implants for a better fit in our subset of patients. The exact magnitude of mismatch which can cause functional implications need to be made out. The mismatch being one of the important factors for the success of the surgery, we should focus more on this aspect.

  19. Managed ventricular pacing vs. conventional dual-chamber pacing for elective replacements: the PreFER MVP study: clinical background, rationale, and design.

    Science.gov (United States)

    Quesada, Aurelio; Botto, Gianluca; Erdogan, Ali; Kozak, Milan; Lercher, Peter; Nielsen, Jens Cosedis; Piot, Olivier; Ricci, Renato; Weiss, Christian; Becker, Daniel; Wetzels, Gwenn; De Roy, Luc

    2008-03-01

    Several clinical studies have shown that, in patients with intact atrioventricular (AV) conduction, unnecessary chronic right ventricular (RV) pacing can be detrimental. The managed ventricular pacing (MVP) algorithm is designed to give preference to spontaneous AV conduction, thus minimizing RV pacing. The clinical outcomes of MVP are being studied in several ongoing trials in patients undergoing a first device implantation, but it is unknown to what extent MVP is beneficial in patients with a history of ventricular pacing. The purpose of the Prefer for Elective Replacement MVP (PreFER MVP) study is to assess the superiority of the MVP algorithm to conventional pacemaker and implantable cardioverter-defibrillator programming in terms of freedom from hospitalization for cardiovascular causes in a population of patients exposed to long periods of ventricular pacing. PreFER MVP is a prospective, 1:1 parallel, randomized (MVP ON/MVP OFF), single-blinded multi-centre trial. The study population consists of patients with more than 40% ventricular pacing documented with their previous device. Approximately, 600 patients will be randomized and followed for at least 24 months. The primary endpoint comprises cardiovascular hospitalization. The PreFER MVP trial is the first large prospective randomized clinical trial evaluating the effect of MVP in patients with a history of RV pacing.

  20. First implantation of selective his bundle pacing in Colombia. Report of two cases

    International Nuclear Information System (INIS)

    Velasquez, Jorge E; Duque, Mauricio; Marin V, Jorge E; Aristizabal, Julian M; Medina, Luis E; Gonzalez, Edgardo; Duque, Laura; Uribe, William

    2010-01-01

    Pacing in the right ventricular apex is known to produce ventricular dysynchrony and patients often develop dilated cardiomyopathy. For this reason, a more physiological stimulation has been performed. With the recent technological development of electrodes for selective stimulation of the His bundle, we want to show the experience of this type of implantation in the first two cases made in the electrophysiology laboratory in Medellin.

  1. Minimally Invasive Epicardial Pacemaker Implantation in Neonates with Congenital Heart Block.

    Science.gov (United States)

    Costa, Roberto; Silva, Katia Regina da; Martinelli Filho, Martino; Carrillo, Roger

    2017-10-01

    Few studies have characterized the surgical outcomes following epicardial pacemaker implantation in neonates with congenital complete atrioventricular block (CCAVB). This study sought to assess the long-term outcomes of a minimally invasive epicardial approach using a subxiphoid access for pacemaker implantation in neonates. Between July 2002 and February 2015, 16 consecutive neonates underwent epicardial pacemaker implantation due to CCAVB. Among these, 12 (75.0%) had congenital heart defects associated with CCAVB. The patients had a mean age of 4.7 ± 5.3 days and nine (56.3%) were female. Bipolar steroid-eluting epicardial leads were implanted in all patients through a minimally invasive subxiphoid approach and fixed on the diaphragmatic ventricular surface. The pulse generator was placed in an epigastric submuscular position. All procedures were successful, with no perioperative complications or early deaths. Mean operating time was 90.2 ± 16.8 minutes. None of the patients displayed pacing or sensing dysfunction, and all parameters remained stable throughout the follow-up period of 4.1 ± 3.9 years. Three children underwent pulse generator replacement due to normal battery depletion at 4.0, 7.2, and 9.0 years of age without the need of ventricular lead replacement. There were two deaths at 12 and 325 days after pacemaker implantation due to bleeding from thrombolytic use and progressive refractory heart failure, respectively. Epicardial pacemaker implantation through a subxiphoid approach in neonates with CCAVB is technically feasible and associated with excellent surgical outcomes and pacing lead longevity.

  2. [Diagnosis and therapy of arrhythmogenic right ventricular cardiomyopathy].

    Science.gov (United States)

    Zorzi, Alessandro; Rigato, Ilaria; Migliore, Federico; Perazzolo Marra, Martina; Basso, Cristina; Thiene, Gaetano; Bauce, Barbara; Corrado, Domenico

    2014-11-01

    Arrhythmogenic right ventricular cardiomyopathy (ARVC) is an inherited heart muscle disease that predisposes to the occurrence of ventricular arrhythmias and sudden death, particularly in the young and athlete. The classic variant of the disease predominantly affects the right ventricle, but phenotypic variants with early and prevalent left ventricular involvement ("left-dominant" ARVC) have also been described, supporting the concept that arrhythmogenic cardiomyopathy is a disease of both ventricles. The diagnosis is multiparametric and is based on a series of criteria, including ECG abnormalities, arrhythmic manifestations, morpho-functional abnormalities and genetic defects. The main goal of therapy is sudden death prevention. Implant of a cardioverter-defibrillator is the most effective strategy for prevention of sudden death, but it should be reserved to selected patients after accurate risk stratification, in view of the high complication rate over a long-term follow-up, the costs and the significant psychological impact of such therapy, especially in the young individual. The other therapies (either pharmacological or not) are palliative and aimed at relieving symptoms and preventing disease progression. The definitive cure of ARVC will be based on the discovery of the molecular mechanisms that are involved in the etiology and pathogenesis of the disease.

  3. Immediate prostheses on one-piece trans-mucosal implants in flapless surgical procedures Case Series Report. Part I: full arch rehabilitations

    Directory of Open Access Journals (Sweden)

    Aris Petros Tripodakis

    2012-06-01

    Full Text Available Aim: The aim of the present case series report is to illustrate a clinical technique and present the application of onepiece transmucosal implants in flapless surgical procedures, supporting full arch immediate prostheses. Materials and methods: A total of 294 implants (Xive TG, Friadent, Germany have been used to support full arch immediate prostheses, over the last six years and have been in function for at least one year. The surgical placement of five or more implants per case involved immediate extraction and intrasocket flapless placement, combined with minimal flap elevation in the areas of healed extraction sites (43 mandibular and 7 maxillary arches. In all cases immediate provisionalization followed. Detailed three-dimensional cone-beam localized volumetric tomography preceeded the surgical procedures. The delivery of the final ceramo-metal prostheses was accomplished within a 20 day period. Materials and methods: Results Six implants failed to osseointegrate. All other implants are still successfully bearing the final prosthesis for the time that they have been followed. Soft tissue reaction was favorable from both the biologic and esthetic point of view. Conclusion: The flapless placement of one piece implants into edentulous healed sites is a predictable procedure in the presence of abundance of supporting bone as confirmed by 3-D imaging. On the other hand, immediate extraction placement of one piece implants allows the engagement of sound bone located deeper into the socket and provides adequate mechanical support of the soft tissue architecture that is preserved predictably. In all cases the prosthetic procedures are accomplished without disturbing the hardsoft tissue interface as the abutment-prosthesis interface is coronally elevated by the virtual design of the implant.

  4. Late Ratchet syndrome involving isolated left ventricular lead dislodgement post-cardiac resynchronization therapy defibrillator generator change.

    Science.gov (United States)

    Tan, Vern Hsen; Wong, Kelvin

    2018-04-01

    Lead dislodgement following cardiac implantable electronic device (CIED) generator change is rare. We report a case including the postulate mechanism of an isolated left ventricular lead dislodgement 3 months after cardiac resynchronization therapy defibrillator pulse generator change.

  5. A new "twist" on right heart failure with left ventricular assist systems.

    Science.gov (United States)

    Houston, Brian A; Shah, Keyur B; Mehra, Mandeep R; Tedford, Ryan J

    2017-07-01

    Despite significant efforts to predict and prevent right heart failure, it remains a leading cause of morbidity and mortality after implantation of left ventricular assist systems (LVAS). In this Perspective, we review the underappreciated anatomic and physiologic principles that govern the relationship between left and right heart function and contribute to this phenomenon. This includes the importance of considering the right ventricle (RV) and pulmonary arterial circuit as a coupled system; the contribution of the left ventricle (LV) to RV contractile function and the potential negative impact of acutely unloading the LV; the influence of the pericardium and ventricular twist on septal function; the role of RV deformation in reduced mechanical efficiency after device placement; and the potential of ongoing stressors of an elevated right-sided preload. We believe an appreciation of these complex issues is required to fully understand the expression of the unique phenotypes of right heart failure after LVAS implantation and for developing better prognostic and therapeutic strategies. Copyright © 2017 International Society for the Heart and Lung Transplantation. Published by Elsevier Inc. All rights reserved.

  6. Cerebrovascular accidents in patients with a ventricular assist device.

    Science.gov (United States)

    Tsukui, Hiroyuki; Abla, Adib; Teuteberg, Jeffrey J; McNamara, Dennis M; Mathier, Michael A; Cadaret, Linda M; Kormos, Robert L

    2007-07-01

    A cerebrovascular accident is a devastating adverse event in a patient with a ventricular assist device. The goal was to clarify the risk factors for cerebrovascular accident. Prospectively collected data, including medical history, ventricular assist device type, white blood cell count, thrombelastogram, and infection, were reviewed retrospectively in 124 patients. Thirty-one patients (25%) had 48 cerebrovascular accidents. The mean ventricular assist device support period was 228 and 89 days in patients with and without cerebrovascular accidents, respectively (P cerebrovascular accidents occurred within 4 months after implantation. Actuarial freedom from cerebrovascular accident at 6 months was 75%, 64%, 63%, and 33% with the HeartMate device (Thoratec Corp, Pleasanton, Calif), Thoratec biventricular ventricular assist device (Thoratec Corp), Thoratec left ventricular assist device (Thoratec), and Novacor device (WorldHeart, Oakland, Calif), respectively. Twenty cerebrovascular accidents (42%) occurred in patients with infections. The mean white blood cell count at the cerebrovascular accident was greater than the normal range in patients with infection (12,900/mm3) and without infection (9500/mm3). The mean maximum amplitude of the thrombelastogram in the presence of infection (63.6 mm) was higher than that in the absence of infection (60.7 mm) (P = .0309). The risk of cerebrovascular accident increases with a longer ventricular assist device support period. Infection may activate platelet function and predispose the patient to a cerebrovascular accident. An elevation of the white blood cell count may also exacerbate the risk of cerebrovascular accident even in patients without infection. Selection of device type, prevention of infection, and meticulous control of anticoagulation are key to preventing cerebrovascular accident.

  7. Effects of AV delay programming on ventricular resynchronisation: role of radionuclide ventriculography

    Energy Technology Data Exchange (ETDEWEB)

    Siegrist, Patrick T.; Comte, Nathalie; Holzmeister, Johannes; Suetsch, Gabor; Koepfli, Pascal; Namdar, Mehdi; Duru, Firat; Brunckhorst, Corinna; Scharf, Christoph [Universitiy Hospital Zurich NUK C 32, Cardiovascular Center, Zurich (Switzerland); Kaufmann, Philipp A. [Universitiy Hospital Zurich NUK C 32, Cardiovascular Center, Zurich (Switzerland); University of Zurich, Zurich Center for Integrative Human Physiology, Zurich (Switzerland)

    2008-08-15

    Optimal atrioventricular delay (AVD) setting for cardiac resynchronisation therapy, i.e. biventricular pacing in patients with heart failure, remains a formidable challenge. Thus, the purpose of this study was to evaluate the effects of different AVD on inter- and intra-ventricular resynchronisation using phase histograms of radionuclide ventriculography (RNV). In 17 consecutive patients (mean age 64 {+-} 6 years), RNV was performed 236 {+-} 350 days after pacemaker implantation for cardiac resynchronisation therapy. Images were acquired during atrial pacing at 80 bpm and during biventricular pacing with AVD ranging from 80 to 160 ms. Inter-ventricular dyssynchrony was measured by the delay between the mean phase angles of the left and right ventricles. Intra-ventricular dyssynchrony was measured by the standard deviation (SD) of left ventricular phase histograms. Left ventricular (LV) ejection fraction (EF) was inversely correlated to LV dyssynchrony (SD of LV phase histogram, R = -0.82, p < 0.0001). However, the increase in LVEF by biventricular pacing (mean +4.4 {+-} 4%) showed only modest correlation to the resulting resynchronisation effect (characterised by a -13 {+-} 8 decrease in LV phase histogram SD, R = -0.38, p < 0.0001). RNV is helpful in optimising pacing parameters for resynchronisation therapy. Varying AVD did not have a major impact on intra- or inter-ventricular resynchronisation. Thus, the benefit of AVD-based LVEF optimisation seems to result from atrioventricular resynchronisation. (orig.)

  8. Pulmonary Hypertension After Heart Transplantation in Patients Bridged with the Total Artificial Heart.

    Science.gov (United States)

    Shah, Rachit; Patel, Dhavalkumar B; Mankad, Anit K; Rennyson, Stephen L; Tang, Daniel G; Quader, Mohammed A; Smallfield, Melissa C; Kasirajan, Vigneshwar; Shah, Keyur B

    2016-01-01

    Pulmonary hypertension (PH) among heart transplant recipients is associated with an increased risk of mortality. Pulmonary hemodynamics improves after left ventricular assist device (LVAD) implantation; however, the impact of PH before total artificial heart (TAH) implantation on posttransplant hemodynamics and survival is unknown. This is a single center retrospective study aimed to evaluate the impact of TAH implantation on posttransplant hemodynamics and mortality in two groups stratified according to severity of PH: high (≥3 Woods units [WU]) and low (heart catheterization performed at baseline (before TAH) and posttransplant at 1 and 12 months. Patients in the high PVR group (n = 12) experienced improvement in PVR (baseline = 4.31 ± 0.7; 1-month = 1.69 ± 0.7, p heart transplantation (HT), but remained elevated. There was no significant difference in survival between the two groups at 12 months follow-up. Patients with high PVR who are bridged to transplant with TAH had improvement in PVR at 12 months after transplant, and the degree of PVR did not impact posttransplant survival.

  9. Noninvasive risk stratification of lethal ventricular arrhythmias and sudden cardiac death after myocardial infarction

    Directory of Open Access Journals (Sweden)

    Kenji Yodogawa, MD

    2014-08-01

    Full Text Available Prediction of lethal ventricular arrhythmias leading to sudden cardiac death is one of the most important and challenging problems after myocardial infarction (MI. Identification of MI patients who are prone to ventricular tachyarrhythmias allows for an indication of implantable cardioverter-defibrillator placement. To date, noninvasive techniques such as microvolt T-wave alternans (MTWA, signal-averaged electrocardiography (SAECG, heart rate variability (HRV, and heart rate turbulence (HRT have been developed for this purpose. MTWA is an indicator of repolarization abnormality and is currently the most promising risk-stratification tool for predicting malignant ventricular arrhythmias. Similarly, late potentials detected by SAECG are indices of depolarization abnormality and are useful in risk stratification. However, the role of SAECG is limited because of its low predictive accuracy. Abnormal HRV and HRT patterns reflect autonomic disturbances, which may increase the risk of lethal ventricular arrhythmias, but the existing evidence is insufficient. Further studies of noninvasive assessment may provide a new insight into risk stratification in post-MI patients.

  10. Presentación tardía de aneurisma ventricular post-infarto. Caracterización por múltiples modalidades de imagen

    Directory of Open Access Journals (Sweden)

    Julio Oscar Cabrera Rego

    2011-12-01

    Full Text Available El aneurisma ventricular verdadero a nivel de la pared posteroinferior es infrecuente. Se presenta el caso de un paciente con episodios de taquicardia ventricular sostenida como primera manifestación de aneurisma ventricular post-infarto diagnosticado por ecocardiografía transtorácica y tridimensional, coronariografía invasiva y tomografía computarizada multicortes. La situación se resolvió favorablemente con optimización del tratamiento médico e implantación de un desfibrilador automático.Late Ventricular Post-myocardial Infarction Aneurysm. Characterization through Several Imaging TestsTrue ventricular aneurysm in the low posterior wall is uncommon. The case of a patient with sustained ventricular tachycardia as first symptom of a post-myocardial left ventricular aneurysm, finally diagnosed through transthoracic 2D and 3D-echocardiography, invasive coronary angiography and multislice computed tomography is presented. Medical treatment was optimized and an automatic implantable cardioverter defibrillator was used. Thus, the patient evolved favourably.

  11. Conjugated linoleic acid (CLA. Cis 9, trans 11 and trans 10, cis 12 isomer detection in crude and refined corn oils by capillary GC

    Directory of Open Access Journals (Sweden)

    Özlem Tokuşoğlu

    2008-06-01

    Full Text Available Conjugated linoleic acids (CLAs exhibit protective effects against various types of cancer and heart diseases. With the newly developed capillary gas chromatographic method (GC, cis9, trans11 and trans10, cis12 octadecadienoic acid isomers of CLA (C18:2 were determined in crude and refined corn oils as qualitative and quantitative measurements. Cis 9, trans11 C18:2 (c9, t11 CLA was the major CLA isomer in both oils. It was found that c9, t11 CLA was 0.62% of the total lipid in crude oil and 1.24% of the total lipid in refined oil. Using the refining process, the total CLA was 1.38% whereas that of crude corn oil was 0.62%. An approximate 2.2 fold increase in the total CLA was found in refined oil (n = 9 (p y = 2.782x + 0.046 (R2 = 0.9999] were performed (p El ácido linoleico conjugado (CLA parece exhibir efecto protector frente a enfermedades cardiovasculares y varios tipos de cáncer. En este trabajo, se establece un mátodo analítico mediante cromatografía de gases con columna capilar para la determinación cualitativa y cuantitativa de los isómeros cis 9,trans 11 y trans 10, cis 12 en aceites de maiz crudo y refinado. El isómero cis 9, trans11 C18:2 fue el mayoritario encontrándose en concentraciones de 0.62% en el aceite cru,do y de 1.24 % en el aceite refinado. La cantidad total de CLA encontrada en el aceite refinado (n = 9 (p 2 = 0.9999 y de recuperación [y = 2.782x+0.046 (R2 = 0.9999]. El método cromatográfico propuesto podría ser usado para el control de calidad de los aceites vegetales.

  12. Current Trends in Implantable Left Ventricular Assist Devices

    Directory of Open Access Journals (Sweden)

    Jens Garbade

    2011-01-01

    Full Text Available The shortage of appropriate donor organs and the expanding pool of patients waiting for heart transplantation have led to growing interest in alternative strategies, particularly in mechanical circulatory support. Improved results and the increased applicability and durability with left ventricular assist devices (LVADs have enhanced this treatment option available for end-stage heart failure patients. Moreover, outcome with newer pumps have evolved to destination therapy for such patients. Currently, results using nonpulsatile continuous flow pumps document the evolution in outcomes following destination therapy achieved subsequent to the landmark Randomized Evaluation of Mechanical Assistance for the Treatment of Congestive Heart Failure Trial (REMATCH, as well as the outcome of pulsatile designed second-generation LVADs. This review describes the currently available types of LVADs, their clinical use and outcomes, and focuses on the patient selection process.

  13. Metastatic spread from squamous cell carcinoma of the hypopharynx to the totally implantable venous access port insertion site: Case report and review of literature.

    Science.gov (United States)

    Mangla, Ankit; Agarwal, Nikki; Mullane, Michael Russell

    2017-12-01

    The totally implantable venous access port plays a crucial role in delivering chemotherapy in the outpatient setting. Here, we report the first case of a patient with hypopharyngeal tumor who developed chest wall metastasis over the totally implantable venous access port inserted in the internal jugular vein. Our patient, a 58-year-old man with a hypopharyngeal tumor presented with a lump over the totally implantable venous access port site. The port was removed and the lump was biopsied. The CT studies showed that the tumor had spread along the catheter from the hypopharynx to the chest wall. The pathology from the biopsy showed squamous cell carcinoma (SCC). The patient had poor performance status and opted for hospice care. We present a novel case of metastasis over the totally implantable venous access port implanted in a patient with a hypopharyngeal tumor. We also reviewed relevant literature comparing the data from percutaneous endoscopic gastrostomy (PEG) tube site metastasis with our patient and other similar case reports. © 2017 Wiley Periodicals, Inc.

  14. Implantation of a cardiac resynchronization therapy-defibrillator device in a patient with persistent left superior vena cava.

    Science.gov (United States)

    Atar, İlyas; Karaçağlar, Emir; Özçalık, Emre; Özin, Bülent; Müderrisoğlu, Haldun

    2015-06-01

    Presence of a persistent left superior vena cava (PLSVC) is generally clinically asymptomatic and discovered incidentally during central venous catheterization. However, PLSVC may cause technical difficulties during cardiac device implantation. An 82-year-old man with heart failure symptoms and an ejection fraction (EF) of 20% was scheduled for resynchronization therapy-defibrillator device (CRT-D) implantation. A PLSVC draining via a dilated coronary sinus into an enlarged right atrium was diagnosed. First, an active-fixation right ventricular lead was inserted into the right atrium through the PLSVC. The stylet was preshaped to facilitate its passage to the right ventricular apex. An atrial lead was positioned on the right atrium free wall, and an over-the-wire coronary sinus lead deployed to a stable position. CRT-D implantation procedure was successfully completed.

  15. Agenesia de cava superior associada a bloqueio atrioventricular de 3º grau Agenesis of the right superior vena cava associated with total heart block

    Directory of Open Access Journals (Sweden)

    Gustavo J. Ventura Couto

    2008-03-01

    Full Text Available A persistência de veia cava superior esquerda com ausência da veia cava superior é uma anomalia rara, principalmente quando associada a bloqueio atrioventricular de 3º grau. Relatamos o caso de uma paciente, na qual durante implante de marca-passo definitivo, para a correção de bloqueio atrioventricular total, foi detectada presença de veia cava superior esquerda com suspeição de ausência de veia cava superior, o que levou ao emprego de técnica diferenciada para fixação do eletrodo ventricular. Para confirmação da provável agenesia, foram realizados diversos exames complementares de imagem, demonstrando-se a dificuldade no diagnóstico da síndrome aqui descrita.The superior left vena cava with the absent superior vena cava is a rare abnormality, especially when associated with total heart block. We report a case of a patient in which the presence of superior left vena cava and the absence of the superior vena cava was detected during the implantation of a pacemaker for the correction of a total heart block, which led us to use a different technique for the fixation of the ventricular electrode. To confirm the supposed absence, several image exams were made showing the difficulty on the diagnosis of the described syndrome.

  16. Prototype Development of an Implantable Compliance Chamber for a Total Artificial Heart.

    Science.gov (United States)

    Schmitz, Stephanie; Unthan, Kristin; Sedlaczek, Marc; Wald, Felix; Finocchiaro, Thomas; Spiliopoulos, Sotirios; Koerfer, Reiner; Steinseifer, Ulrich

    2017-02-01

    At our institute a total artificial heart is being developed. It is directly actuated by a linear drive in between two ventricles, which comprise membranes to separate the drive and blood flow. A compliance chamber (CC) is needed to reduce pressure peaks in the ventricles and to increase the pump capacity. Therefore, the movement of the membrane is supported by applying a negative pressure to the air volume inside the drive unit. This study presents the development of the implantable CC which is connected to the drive unit of the total artificial hearts (TAH). The anatomical fit of the CC is optimized by analyzing CT data and adapting the outer shape to ensure a proper fit. The pressure peaks are reduced by the additional volume and the flexible membrane of the CC. The validation measurements of change in pressure peaks and flow are performed using the complete TAH system connected to a custom mock circulation loop. Using the CC, the pressure peaks could be damped below 5 mm Hg in the operational range. The flow output was increased by up to 14.8% on the systemic side and 18.2% on the pulmonary side. The described implantable device can be used for upcoming chronic animal trials. © 2016 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  17. Left ventricular assist device: exercise capacity evolution and rehabilitation added value.

    Science.gov (United States)

    Lamotte, Michel X; Chimenti, Sara; Deboeck, Gael; Gillet, Alexis; Kacelenenbogen, Raymond; Strapart, Jonathan; Vandeneynde, Frédéric; Van Nooten, Guido; Antoine, Martine

    2018-06-01

    With more than 15,000 implanted patients worldwide and a survival rate of 80% at 1-year and 59% at 5-years, left ventricular assist device (LVAD) implantation has become an interesting strategy in the management of heart failure patients who are resistant to other kinds of treatment. There are limited data in the literature on the change over time of exercise capacity in LVAD patients, as well as limited knowledge about the beneficial effects that rehabilitation might have on these patients. Therefore, the aim of our study was to evaluate the evolution of exercise capacity on a cohort of patients implanted with the same device (HeartWare © ) and to analyse the potential impact of rehabilitation. Sixty-two patients implanted with a LVAD between June 2011 and June 2015 were screened. Exercise capacity was evaluated by cardiopulmonary exercise testing at 6 weeks, 6 and 12 months after implantation. We have observed significant differences in the exercise capacity and evolution between the trained and non-trained patients. Some of the trained patients nearly normalised their exercise capacity at the end of the rehabilitation programme. Exercise capacity of patient implanted with a HeartWare © LVAD increased in the early period after implantation. Rehabilitation allowed implanted patients to have a significantly better evolution compared to non-rehabilitated patients.

  18. Postmortem analysis of encapsulation around long-term ventricular endocardial pacing leads.

    Science.gov (United States)

    Candinas, R; Duru, F; Schneider, J; Lüscher, T F; Stokes, K

    1999-02-01

    To analyze the site and thickness of encapsulation around ventricular endocardial pacing leads and the extent of tricuspid valve adhesion, from today's perspective, with implications for lead removal and sensor location. Gross cardiac postmortem analysis was performed in 11 cases (8 female and 3 male patients; mean age, 78+/-7 years). None of the patients had died because of pacemaker malfunction. The mean implant time was 61+/-60 months (range, 4 to 184). The observations ranged from encapsulation only at the tip of the pacing lead to complete encapsulation along the entire length of the pacing lead within the right ventricle. Substantial areas of adhesion at the tricuspid valve apparatus were noted in 7 of the 11 cases (64%). The firmly attached leads could be removed only by dissection, and in some cases, removal was possible only by damaging the associated structures. No specific optimal site for sensor placement could be identified along the ventricular portion of the pacing leads; however, the fibrotic response was relatively less prominent in the atrial chamber. Extensive encapsulation is present in most long-term pacemaker leads, which may complicate lead removal. The site and thickness of encapsulation seem to be highly variable. Tricuspid valve adhesion, which is usually underestimated, may be severe. In contrast to earlier reports, our study demonstrates that the extent of fibrotic encapsulation may not be related to the duration since lead implantation. Moreover, we noted no ideal encapsulation-free site for sensors on the ventricular portion of long-term pacing leads.

  19. Echocardiographic evaluation of right ventricular stroke work index in advanced heart failure: a new index?

    Science.gov (United States)

    Frea, Simone; Bovolo, Virginia; Bergerone, Serena; D'Ascenzo, Fabrizio; Antolini, Marina; Capriolo, Michele; Canavosio, Federico Giovanni; Morello, Mara; Gaita, Fiorenzo

    2012-12-01

    Right ventricular (RV) function plays a pivotal role in advanced heart failure patients, especially for screening those who may benefit from left ventricular assist device (LVAD) implantation. We introduce RV contraction pressure index (RVCPI) as a new echo-Doppler parameter of RV function. The accuracy of RVCPI in detecting RV failure was compared with the criterion standard, the RV stroke work index (RVSWI) obtained through right heart catheterization in advanced heart failure patients referred for heart transplantation or LVAD implantation. Right heart catheterization and echo-Doppler were simultaneously performed in 94 consecutive patients referred to our center for advanced heart failure (ejection fraction (EF) 24 ± 8.8%, 40% NYHA functional class IV). RV stroke volume and invasive pulmonary pressures were used to obtain RVSWI. Simplified RVCPI (sRVCPI) was derived as TAPSE × (RV - right atrial pressure gradient). Close positive correlation between sRVCPI and RVSWI was found (r = 0.68; P rights reserved.

  20. Role of ventricular assist therapy for patients with heart failure and restrictive physiology: Improving outcomes for a lethal disease.

    Science.gov (United States)

    Grupper, Avishay; Park, Soon J; Pereira, Naveen L; Schettle, Sarah D; Gerber, Yariv; Topilsky, Yan; Edwards, Brooks S; Daly, Richard C; Stulak, John M; Joyce, Lyle D; Kushwaha, Sudhir S

    2015-08-01

    Restrictive cardiomyopathy (RCM) patients have poor prognosis due to progressive heart failure characterized by impaired ventricular filling of either or both ventricles. The goal of this study was to evaluate the outcome of end-stage RCM patients after left ventricular assist device (LVAD) implantation and to determine factors that may be associated with improved survival. This investigation is a retrospective study of prospectively collected data that include 28 consecutive patients with end-stage RCM who received continuous-flow LVADs at the Mayo Clinic, Rochester, Minnesota. Outcome was assessed by survival with LVAD support until heart transplantation or all-cause mortality. The mean follow-up time post-LVAD implantation was 448 ± 425 days. The mean hospitalization time was 29 ± 19 days and was complicated mainly by post-operative right ventricular (RV) failure requiring short-term medical support. The short-term in-hospital mortality was 14%. Ten patients underwent heart transplantation with 100% survival post-transplant during the follow-up period. One-year survival for patients with LVADs without transplantation was 64%, and was not significantly different between amyloidosis and non-amyloidosis patients. Larger left ventricle (LV) end-diastolic and end-systolic dimensions were significantly associated with improved survival rates (RR = 0.94 and 0.95, p < 0.05, respectively), and left ventricular end-diastolic diameter (LVEDD) ≤46 mm was associated with increased mortality post-LVAD implantation. LVAD is a feasible, life-saving therapy for end-stage heart failure related to RCM, especially as a bridge to transplant and in patients with larger LV dimensions. Copyright © 2015 International Society for Heart and Lung Transplantation. Published by Elsevier Inc. All rights reserved.

  1. Trans-dinitroglycoluril isomers-A DFT treatment

    Directory of Open Access Journals (Sweden)

    Lemi Türker

    2017-02-01

    Full Text Available Isomers of trans-1,4-Dinitroglycoluril (trans-DINGU and their 1,3-tautomers are considered within the constraints of B3LYP/6-31++G (d,p and B3LYP/CC-PVTZ levels of DFT calculations. Additionally, the interactions of these isomers and proton in vacuum are investigated. The data have revealed that two of the three isomers undergo CH bond cleavage as the result of interaction with proton in vacuum. The total energies, some structural properties, the calculated IR and UV spectra are discussed.

  2. Proximal thoracic aorta dimensions after continuous-flow left ventricular assist device implantation: Longitudinal changes and relation to aortic valve insufficiency.

    Science.gov (United States)

    Fine, Nowell M; Park, Soon J; Stulak, John M; Topilsky, Yan; Daly, Richard C; Joyce, Lyle D; Pereira, Naveen L; Schirger, John A; Edwards, Brooks S; Lin, Grace; Kushwaha, Sudhir S

    2016-04-01

    In this study we examined the impact of continuous-flow left ventricular assist device (CF-LVAD) support on proximal thoracic aorta dimensions. Aortic root and ascending aorta diameter were measured from serial echocardiograms before and after CF-LVAD implantation in patients with ≥6 months of support, and correlated with the development of >mild aortic valve insufficiency (AI). Of 162 patients included, mean age was 58 ± 11 years and 128 (79%) were male. Seventy-nine (63%) were destination therapy patients. Mean aortic root and ascending aorta diameters at baseline, 1 month, 6 months, 12 months and long-term follow-up (mean 2.0 ± 1.4 years) were 3.5 ± 0.4, 3.5 ± 0.3, 3.9 ± 0.3, 3.9 ± 0.2 and 4.0 ± 0.3, and 3.3 ± 0.2, 3.3 ± 0.3, 3.6 ± 0.2, 3.6 ± 0.3 and 3.6 ± 0.3 cm, respectively. Only change in aortic root diameter from 1-month to 6-month follow-up reached statistical significance (p = 0.03). Nine (6%) patients had accelerated proximal thoracic aorta expansion (>0.5 cm/year), occurring predominantly in the first 6 months after implantation. These patients were older and more likely to have hypertension and baseline proximal thoracic aorta dilation. Forty-five (28%) patients developed >mild AI at long-term follow-up, including 7 of 9 (78%) of those with accelerated proximal thoracic aorta expansion. All 7 had aortic valves that remained closed throughout the cardiac cycle, and this, along with duration of CF-LVAD support and increase in aortic root diameter, were significantly associated with developing >mild AI. CF-LVAD patients have small increases in proximal thoracic aorta dimensions that predominantly occur within the first 6 months after implantation and then stabilize. Increasing aortic root diameter was associated with AI development. Copyright © 2016 International Society for Heart and Lung Transplantation. Published by Elsevier Inc. All rights reserved.

  3. Does reducing unnecessary right ventricular pacing improve sympathetic activity and innervation of heart in sinus node disease patients? MVP and SafeR study.

    Science.gov (United States)

    Miyamoto, Mihoko; Kimura, Yuichiro; Hosoda, Junya; Matsumoto, Katsumi; Matsushita, Kohei; Ishikawa, Toshiyuki; Umemura, Satoshi

    2012-01-01

    Ventricular desynchronization imposed by ventricular pacing causes regional disturbances of adrenergic innervation in the left ventricular myocardium and increases the risk of heart failure and atrial fibrillation (AF) in patients with sinus node disease (SND). As a result, decreased iodine-123 metaiodobenzylguanidine (I-(123 )MIBG) uptake occurs in patients with an implanted permanent pacemaker. Fourteen SND patients with an implanted pacemaker equipped with an algorithm for reducing unnecessary right ventricular pacing (RURVP) were enrolled. Pacemakers were programmed to RURVP mode for the first 12 weeks, and then reprogrammed to DDD for the last 12 weeks. At the end of each mode, data on cumulative percent ventricular pacing (%Vp), atrial high rate episodes (%AHR), I-(123 )MIBG myocardial scintigraphy, brain natriuretic peptide (BNP), human atrial natriuretic peptide (hANP), and myocardial damage indices typified by troponin T and C-reactive protein (CRP) were collected. %Vp was lower in RURVP than in DDD (0.2% versus 95.7%, P = 0.00098). BNP, hANP, troponin T, and CRP did not differ significantly between the pacing modes. However, I-(123 )MIBG findings of patients with full ventricular pacing in DDD improved in RURVP. In contrast, among patients without full ventricular pacing in DDD, their I-(123 )MIBG findings did not differ significantly between the pacing modes. In SND patients with normal cardiac function and intact atrioventricular conduction, the reduction of %Vp in RURVP was due to the reduction of ineffective pacing and fusion pacing in DDD. Therefore, these 2 types of pacing do not affect cardiac pump function.

  4. A new one-step procedure for pulmonary valve implantation of the melody valve: Simultaneous prestenting and valve implantation.

    Science.gov (United States)

    Boudjemline, Younes

    2018-01-01

    To describe a new modification, the one-step procedure, that allows interventionists to pre-stent and implant a Melody valve simultaneously. Percutaneous pulmonary valve implantation (PPVI) is the standard of care for managing patients with dysfunctional right ventricular outflow tract, and the approach is standardized. Patients undergoing PPVI using the one-step procedure were identified in our database. Procedural data and radiation exposure were compared to those in a matched group of patients who underwent PPVI using the conventional two-step procedure. Between January 2016 and January 2017, PPVI was performed in 27 patients (median age/range, 19.1/10-55 years) using the one-step procedure involving manual crimping of one to three bare metal stents over the Melody valve. The stent and Melody valve were delivered successfully using the Ensemble delivery system. No complications occurred. All patients had excellent hemodynamic results (median/range post-PPVI right ventricular to pulmonary artery gradient, 9/0-20 mmHg). Valve function was excellent. Median procedural and fluoroscopic times were 56 and 10.2 min, respectively, which significantly differed from those of the two-step procedure group. Similarly, the dose area product (DAP), and radiation time were statistically lower in the one-step group than in the two-step group (P step procedure is a safe modification that allows interventionists to prestent and implants the Melody valve simultaneously. It significantly reduces procedural and fluoroscopic times, and radiation exposure. © 2017 Wiley Periodicals, Inc.

  5. Arrhythmogenic right ventricular cardiomyopathy in monozygotic twin sisters, and persistent left superior vena cava in one complicating implantation of ICD.

    Science.gov (United States)

    Astarcıoğlu, Mehmet Ali; Yaymacı, Mehmet; Şen, Taner; Kilit, Celal; Amasyalı, Basri

    2015-10-01

    Arrhythmogenic right ventricular cardiomyopathy (ARVC) is an inherited cardiomyopathy characterized histologically by fibro-fatty replacement of heart muscle, and clinically by ventricular arrhythmias and right ventricular dysfunction. This report presents monozygotic twins with ARVC, suggesting a genetic abnormality as the most probable cause.

  6. A Comparison of Clinical Outcomes with Regular- and Low-Profile Totally Implanted Central Venous Port Systems

    International Nuclear Information System (INIS)

    Teichgraeber, Ulf Karl-Martin; Steitparth, Florian; Cho, Chie Hee; Benter, Thomas; Gebauer, Bernhard

    2009-01-01

    The purpose of this study was to evaluate whether low-profile totally implanted central venous port systems can reduce the late complication of skin perforation. Forty patients (age, 57 ± 13 years; 22 females, 18 males) were randomized for the implantation of a low-profile port system, and another 40 patients (age, 61 ± 14 years; 24 females, 16 males) received a regular port system as control group. Indications for port catheter implantation were malignant disease requiring chemotherapy. All port implantations were performed in the angiography suite using sonographically guided central venous puncture and fluoroscopic guidance of the catheter placement. Procedure time, number of complications (procedure-related immediate, early, and late complications), and number of explantations were assessed. Follow-up was performed for 6 months. All port implantations were successfully completed in both study groups. There were two incidents of skin perforation observed in the control group. One skin perforation occurred 13 weeks and the other 16 weeks after port implantation (incidence, 5%) in patients with regular-profile port systems. Two infections were observed, one port infection in each study group. Both infections were characterized as catheter-related infections (infection rate: 0.15 catheter-related infections per 1000 catheter days). In conclusion, low-profile port systems can be placed as safely as traditional chest ports and reduce the risk of developing skin perforations, which occurs when the port system is too tight within the port pocket.

  7. Immediate electrical storm of Torsades de Pointes after CRT-D implantation in an ischemic cardiomyopathy patient

    Directory of Open Access Journals (Sweden)

    Adnan Kaya, MD

    2015-06-01

    Full Text Available Cardiac resynchronization therapy with an implantable cardioverter-defibrillator (CRT-D is the preferred treatment for patients with severe heart failure, dyssynchrony, and an increased risk of sudden cardiac death or for primary ventricular arrhythmia survivors. Rarely, left ventricular epicardial pacing can induce ventricular tachyarrhythmia rather than a beneficial effect. We describe an ischemic cardiomyopathy patient who underwent CRT-D therapy and developed sustained torsades de pointes (TdP immediately after switching to biventricular pacing (BVP mode. Here, TdP possibly developed owing to the change in the dispersion of repolarization of the left ventricle myocardium. The diagnosis and management of BVP-induced ventricular arrhythmia is discussed.

  8. System overview of the fully implantable destination therapy--ReinHeart-total artificial heart.

    Science.gov (United States)

    Pelletier, Benedikt; Spiliopoulos, Sotirios; Finocchiaro, Thomas; Graef, Felix; Kuipers, Kristin; Laumen, Marco; Guersoy, Dilek; Steinseifer, Ulrich; Koerfer, Reiner; Tenderich, Gero

    2015-01-01

    Owing to the lack of suitable allografts, the demand for long-term mechanical circulatory support in patients with biventricular end-stage heart failure is rising. Currently available Total Artificial Heart (TAH) systems consist of pump units with only limited durability, percutaneous tubes and bulky external equipment that limit the quality of life. Therefore we are focusing on the development of a fully implantable, highly durable destination therapy total artificial heart. The ReinHeart-TAH system consists of a passively filling pump unit driven by a low-wear linear drive between two artificial ventricles, an implantable control unit and a compliance chamber. The TAH is powered by a transcutaneous energy transmission system. The flow distribution inside the ventricles was analysed by fluid structure interaction simulation and particle image velocimetry measurements. Along with durability tests, the hydrodynamic performance and flow balance capability were evaluated in a mock circulation loop. Animal trials are ongoing. Based on fluid structure interaction simulation and particle image velocimetry, blood stagnation areas have been significantly reduced. In the mock circulation loop the ReinHeart-TAH generated a cardiac output of 5 l/min at an operating frequency of 120 bpm and an aortic pressure of 120/80 mmHg. The highly effective preload sensitivity of the passively filling ventricles allowed the sensorless integration of the Frank Starling mechanism. The ReinHeart-TAH effectively replaced the native heart's function in animals for up to 2 days. In vitro and in vivo testing showed a safe and effective function of the ReinHeart-TAH system. This has the potential to become an alternative to transplantation. However, before a first-in-man implant, chronic animal trials still have to be completed. © The Author 2014. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  9. Management of patients with Arrhythmogenic Right Ventricular Cardiomyopathy in the Nordic countries.

    Science.gov (United States)

    Haugaa, Kristina H; Bundgaard, Henning; Edvardsen, Thor; Eschen, Ole; Gilljam, Thomas; Hansen, Jim; Jensen, Henrik Kjærulf; Platonov, Pyotr G; Svensson, Anneli; Svendsen, Jesper H

    2015-01-01

    Diagnostics of patients with arrhythmogenic right ventricular cardiomyopathy (ARVC) are complex, and based on the 2010 Task Force document including different diagnostic modalities. However, recommendations for clinical management and follow-up of patients with ARVC and their relatives are sparse. This paper aims to give a practical overview of management strategies, risk stratification, and selection of appropriate therapies for patients with ARVC and their family members. This paper summarizes follow-up and treatment strategies in ARVC patients in the Nordic countries. The author group represents cardiologists who are actively involved in the Nordic ARVC Registry which was established in 2009, and contains prospectively collected clinical data from more than 590 ARVC patients from Denmark, Norway, Sweden, and Finland. Different approaches of management and follow-up are required in patients with definite ARVC and in genetic-mutation-positive family members. Furthermore, ARVC patients with and without implantable cardioverter defibrillators (ICDs) require different follow-up strategies. Careful follow-up is required in patients with ARVC diagnosis to evaluate the need of anti-arrhythmic therapy and ICD implantation. Mutation-positive family members should be followed regularly for detection of early disease and risk stratification of ventricular arrhythmias.

  10. Right ventricular function in patients with dilated cardiomyopathy

    International Nuclear Information System (INIS)

    Kubota, Shuhei; Kubota, Sachio; Iwase, Takashi; Iizuka, Toshio; Imai, Susumu; Murata, Kazuhiko; Inoue, Tomio; Suzuki, Tadashi; Sasaki, Yasuhito.

    1993-01-01

    The characteristics and pathogenesis of right ventricular dysfunction in 14 patients with dilated cardiomyopathy (DCM) were investigated by equilibrium right ventricular blood pool scintigraphy using ultrashort-lifetime 81m Kr. Thirteen patients with severe left ventricular dysfunction due to old anterior myocardial infarction (OMI) and nine normal subjects were used as controls. The right ventricular end-diastolic pressure and volume index, mean pulmonary arterial pressure, and total pulmonary vascular resistance index were almost the same in the DCM and OMI patients. The right ventricular ejection fraction was 44.2±6.0% (mean±SD) in DCM patients and 47.1±7.9% in OMI patients, both significantly lower than those in the normal subjects (54.5±5.3%), but with no difference between the two case groups. The right ventricular peak filling rate was significantly reduced in both case groups as compared with the normal subjects (2.46±0.81 EDV/sec). The reduction was significantly greater (p 81m Kr blood pool scintigraphy is useful in the study of the right ventricular systolic and diastolic function. The diastolic parameters are more sensitive indicators for evaluation of right ventricular function in DCM than the systolic parameters. (author)

  11. Primer implante de electrodo de estimulación selectiva del haz de His en Colombia: Reporte de dos casos First implantation of selective his bundle pacing in Colombia: Report of two cases

    Directory of Open Access Journals (Sweden)

    Jorge E Velásquez

    2010-06-01

    Full Text Available Se conoce que la estimulación en el ápex del ventrículo derecho produce disincronía ventricular y muchas veces los pacientes desarrollan miocardiopatía dilatada, lo que ha llevado a realizar una estimulación más fisiológica. Con el reciente desarrollo tecnológico de los electrodos para la estimulación selectiva del haz de His (fisiológica, se quiere mostrar la experiencia en el implante de este tipo de electrodos en los dos primeros casos del servicio de electrofisiología de la Clínica Medellín.Pacing in the right ventricular apex is known to produce ventricular dysynchrony and patients often develop dilated cardiomiopathy. For this reason, a more physiological stimulation has been performed. With the recent technological development of electrodes for selective stimulation of the His bundle, we want to show the experience of this type of implantation in the first two cases made in the electrophysiology laboratory in Medellin.

  12. Left ventricular assist device implantation via left thoracotomy: alternative to repeat sternotomy.

    Science.gov (United States)

    Pierson, Richard N; Howser, Renee; Donaldson, Terri; Merrill, Walter H; Dignan, Rebecca J; Drinkwater, Davis C; Christian, Karla G; Butler, Javed; Chomsky, Don; Wilson, John R; Clark, Rick; Davis, Stacy F

    2002-03-01

    Repeat sternotomy for left ventricular assist device insertion may result in injury to the right heart or patent coronary grafts, complicating intraoperative and postoperative management. In 4 critically ill patients, left thoracotomy was used as an alternative to repeat sternotomy. Anastomosis of the outflow conduit to the descending thoracic aorta provided satisfactory hemodynamic support.

  13. Effect of defibrillation threshold testing on effectiveness of the subcutaneous implantable cardioverter defibrillator.

    Science.gov (United States)

    Peddareddy, Lakshmi; Merchant, Faisal M; Leon, Angel R; Smith, Paige; Patel, Akshar; El-Chami, Mikhael F

    2018-06-12

    Defibrillation threshold (DFT) testing is recommended with the subcutaneous ICD (SICD). To describe first shock efficacy for appropriate SICD therapies stratified by the presence of implant DFT testing. We reviewed all patients receiving SICDs at our institution and stratified them based on whether implant DFT testing was performed. Appropriate shocks were reviewed to see if ventricular tachycardia/ventricular fibrillation (VT/VF) terminated with a single shock. First shock efficacy was stratified by implant DFT status. 178 patients implanted with SICDs and followed in our center were included in this study. Of these, 135 (76 %) underwent DFT testing (DFT (+) group). In the DFT (+) 80 appropriate shocks were needed to treat 69 episodes of VT/VF. The first shock was effective in 61 out of 69 episodes (88.4 %), whereas multiple shocks were required to terminate VT/VF in the remaining 8 episodes. Among 43 patients without implant DFT testing (DFT (-) group), 20 appropriate shocks to treat 17 episodes of VT/VF occurred in 7 patients. VT/VF was successfully terminated with the first shock in 16 out of 17 episodes (first shock efficacy 94.1 %). There was no significant difference in first shock effectiveness between those with and without implant DFT testing (p = 0.97). A strategy that omits DFT testing at implant did not appear to compromise the effictiveness of the SICD. These data suggest that routine DFT testing at SICD implant might not be necessary. Randomized trials are needed to confirm this finding. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  14. Significance of change in serum bilirubin in predicting left ventricular reverse remodeling and outcomes in heart failure patients with cardiac resynchronization therapy.

    Science.gov (United States)

    Hosoda, Junya; Ishikawa, Toshiyuki; Matsumoto, Katsumi; Iguchi, Kohei; Matsushita, Hirooki; Ogino, Yutaka; Taguchi, Yuka; Sugano, Teruyasu; Ishigami, Tomoaki; Kimura, Kazuo; Tamura, Kouichi

    2017-11-01

    Research on the correlation of serum bilirubin level with cardiac function as well as outcomes in heart failure patients with cardiac resynchronization therapy (CRT) has not yet been reported. The aim of this study was to analyze the relationship between change in serum bilirubin level and left ventricular reverse remodeling, and also to clarify the impact of bilirubin change on clinical outcomes in CRT patients. We evaluated 105 consecutive patients who underwent CRT. Patients who had no serum total-bilirubin data at both baseline and 3-9 months' follow-up or had died less than 3 months after CRT implantation were excluded. Accordingly, a total of 69 patients were included in the present analysis. The patients were divided into two groups: decreased bilirubin group (serum total-bilirubin level at follow-up≤that at baseline; n=48) and increased bilirubin group (serum total-bilirubin level at follow-up>that at baseline; n=21). Mean follow-up period was 39.3 months. In the decreased bilirubin group, mean left ventricular end-systolic diameter decreased from 54.5mm to 50.2mm (p=0.001) and mean left ventricular ejection fraction increased significantly from 29.8% to 37.0% (p=0.001). In the increased bilirubin group, there was no significant change in echocardiographic parameters from baseline to follow-up. In Kaplan-Meyer analysis, cardiac mortality combined with heart failure hospitalization in the increased bilirubin group was significantly higher than that in the decreased bilirubin group (log-rank p=0.018). Multivariate Cox regression analysis revealed that increased bilirubin was an independent predictor of cardiac mortality combined with heart failure hospitalization (OR=2.66, p=0.023). The change in serum bilirubin is useful for assessment of left ventricular reverse remodeling and prediction of outcomes in heart failure patients with CRT. Copyright © 2017 Japanese College of Cardiology. Published by Elsevier Ltd. All rights reserved.

  15. THE INFLUENCE OF SURFACE-FREE ENERGY ON SUPRAGINGIVAL AND SUBGINGIVAL PLAQUE MICROBIOLOGY - AN IN-VIVO STUDY ON IMPLANTS

    NARCIS (Netherlands)

    QUIRYNEN, M; VANDERMEI, HC; BOLLEN, CML; VANDENBOSSCHE, LH; DOORNBUSCH, GI; VANSTEENBERGHE, D; BUSSCHER, HJ

    THE INFLUENCE OF SURFACE FREE ENERGY on supra- and subgingival plaque microbiology was examined in 9 patients with functional fixed prostheses supported by endosseous titanium implants. Two abutments (trans-mucosal part of the 2 stage implant) were replaced by either a new titanium abutment or a

  16. Heart rate turbulence and variability in patients with ventricular arrhythmias

    Directory of Open Access Journals (Sweden)

    Diego Tarricone

    2009-08-01

    Full Text Available Background: To evaluate the changes in autonomic neural control mechanisms before malignant ventricular arrhythmias, we measured heart rate variability (HRV and heart rate turbulence (HRT in patients with ventricular tachycardia or fibrillation (Group I; n=6, non sustained ventricular tachycardia (Group II; n=32, frequent premature ventricular beats (Group III; n=26 and with ICD implantation (Group IV; n=11. Methods: Time domain parameters of HRV and turbulence onset (TO and slope (TS were calculated on 24 hour Holter recordings. Normal values were: SDNN > 70 msec for HRV, TO <0% and TS >2.5 msec/RR-I for HRT. Results: Whereas SDNN was within normal range and similar in all study groups, HRT parameters were significantly different in patients who experienced VT/VF during Holter recording. Abnormal TO and/or TS were present in 100% of Group I patients and only in about 50% of Group II and IV. On the contrary, normal HRT parameters were present in 40-70% of Group II, III and IV patients and none of Group I. Conclusions: These data suggest that HRT analysis is more suitable than HRV to detect those transient alterations in autonomic control mechanisms that are likely to play a major trigger role in the genesis of malignant cardiac arrhythmias. (Heart International 2007; 3: 51-7

  17. Current state of knowledge and experts' perspective on the subcutaneous implantable cardioverter-defibrillator.

    Science.gov (United States)

    Santini, Massimo; Cappato, Riccardo; Andresen, Dietrich; Brachmann, Johannes; Davies, D Wyn; Cleland, John; Filippi, Alessandro; Gronda, Edoardo; Hauer, Richard; Steinbeck, Gerhard; Steinhaus, David

    2009-06-01

    ICD implantation is today a well-recognized therapy to prevent sudden cardiac death. The available implantable devices at present need the use of permanent endocavitary leads which may cause, in some instances, serious troubles to the patients (lead dislodgement, ventricular perforation, lead infections, etc.). A new implantable defibrillator provided by only a subcutaneous lead is at present under evaluation. Its potential indications, usefulness benefits, and problems represent an interesting field of investigation and discussion. This paper describes the conclusions recently reached by a panel of experts, with regard to the potential role of an implantable subcutaneous defibrillator in the prevention of sudden cardiac death.

  18. Visual acuity after trans-scleral sutured posterior chamber intraocular lens

    International Nuclear Information System (INIS)

    Mahmood, S.A.; Zafar, S.

    2014-01-01

    To determine the changes in visual acuity in patients undergoing Trans-Scleral Sutured Posterior Chamber Intra-Ocular Lens (TSSPCIOL) implantation at a tertiary care hospital in Karachi, Pakistan. Study Design: Case series. Place and Duration of Study: LRBT Tertiary Eye Hospital, Karachi, from January 2006 to December 2010. Methodology: Records of all patients undergoing implantation of TSSPCIOL were reviewed. Patients with diagnosed glaucoma, diabetic retinopathy, macular degeneration, history of recurrent uveitis, corneal haze or central corneal scars were excluded. For the final analysis, 70 eyes out of a total of 75 were selected. Main outcomes of interest were pre and postoperative visual acuities and surgical complications. SPSS 21 was used for data analysis. Results: Pre-operatively, the average Best Spectacle-Corrected Visual Acuity (BSCVA) was 6/36 on the Snellen chart. This improved to 6/12 postoperatively. The mean improvement seen was 2.4 lines on the Snellen chart (p < 0.05). Complications include transient intraocular pressure elevation in 25 eyes (36%), IOL tilt in 4 eyes (7.1%), Cystoid Macular Edema (CME) in 4 eyes (5.7%), vitreous haemorrhage in 2 eyes (2.9%), hyphema in 2 eyes (2.9%), uveitis in 1 eye (1.4%), and retinal detachment 1 eye (1.4%). No IOL subluxation, suture erosion, iris capture, choroidal effusion or endophthalmitis was encountered and no re-operations were needed. Conclusion: TSSPCIOLs are a good management option for patients with aphakia in whom PC IOLs cannot be placed. (author)

  19. Imaging of implants on chest radiographs: a radiological perspective

    International Nuclear Information System (INIS)

    Burney, K.; Thayur, N.; Husain, S.A.; Martin, R.P.; Wilde, P.

    2007-01-01

    Endovascular and percutaneous techniques have emerged as alternatives to surgical management in the treatment for a wide range of congenital and acquired cardiac, non-vascular and vascular conditions. Consequently, there has been an increasing use of implants such as closure devices, vascular stents (coronary, aortic, pulmonary and superior vena cava) and non-vascular stents like oesophageal and tracheo-bronchial stents. A large number of percutaneously sited implants are used for treating congenital cardiac anomalies such as atrial septal defects (ASD), ventricular septal defects (VSD), and patent ductus arteriosus (PDA). These implants take many shapes and forms. The aim of this review is to demonstrate the radiographic appearances of the various types of cardiovascular, bronchial and oesophageal implants that are visible on plain films. A brief outline of the aims and indications of various implant procedures, the general appearance of the commonest types of implants, and the radiological procedures are discussed. All radiologists are likely to come across implanted devices in plain film reporting. Imaging can be useful in identifying the device, assessing the position, integrity, and for the identification of complications related directly to the implant

  20. Imaging of implants on chest radiographs: a radiological perspective

    Energy Technology Data Exchange (ETDEWEB)

    Burney, K [Department of Clinical Radiology, Bristol Royal Infirmary (United Kingdom); Thayur, N [Department of Clinical Radiology, Bristol Royal Infirmary (United Kingdom); Husain, S A [Department of Respiratory Medicine, Bristol Royal Infirmary (United Kingdom); Martin, R P [Department of Cardiology, Bristol Royal Hospital for Children, Bristol (United Kingdom); Wilde, P [Department of Clinical Radiology, Bristol Royal Infirmary (United Kingdom)

    2007-03-15

    Endovascular and percutaneous techniques have emerged as alternatives to surgical management in the treatment for a wide range of congenital and acquired cardiac, non-vascular and vascular conditions. Consequently, there has been an increasing use of implants such as closure devices, vascular stents (coronary, aortic, pulmonary and superior vena cava) and non-vascular stents like oesophageal and tracheo-bronchial stents. A large number of percutaneously sited implants are used for treating congenital cardiac anomalies such as atrial septal defects (ASD), ventricular septal defects (VSD), and patent ductus arteriosus (PDA). These implants take many shapes and forms. The aim of this review is to demonstrate the radiographic appearances of the various types of cardiovascular, bronchial and oesophageal implants that are visible on plain films. A brief outline of the aims and indications of various implant procedures, the general appearance of the commonest types of implants, and the radiological procedures are discussed. All radiologists are likely to come across implanted devices in plain film reporting. Imaging can be useful in identifying the device, assessing the position, integrity, and for the identification of complications related directly to the implant.

  1. A comparison of the health status and psychological distress of partners of patients with a left ventricular assist device versus an implantable cardioverter defibrillator

    DEFF Research Database (Denmark)

    Brouwers, Corline; Caliskan, Kadir; de Jonge, Nicolaas

    2014-01-01

    (F = 10.71, p = .001) but poorer mental health status (F = 14.82, p depression scores compared to ICD partners (F = 3.68, p = .05) at 6 months follow-up, also in adjusted analyses. There was no significant difference between groups on anxiety. CONCLUSION: Caregivers of LVAD......OBJECTIVE: To examine if the caregiving for patients with a left ventricular assist device (LVAD) is related to a poorer health status and more distress compared to patients with an implantable cardioverter defibrillator (ICD). BACKGROUND: Partners distress may influence patient outcomes...... and is therefore an important aspect in the care of LVAD and ICD patients. METHODS: Multi-center prospective observational study with 6 months follow-up of 33 LVAD partners (27% men; mean age = 54 ± 10 years) and 414 ICD partners (22% men; mean age = 60 ± 12 years). RESULTS: LVAD partners reported better physical...

  2. Lightlike Hypersurfaces in Indefinite Trans-Sasakian Manifolds

    International Nuclear Information System (INIS)

    Massamba, Fortune

    2010-07-01

    This paper deals with lightlike hypersurfaces of indefinite trans-Sasakian manifolds of type (α, β), tangent to the structure vector field. Characterization Theorems on parallel vector fields, integrable distributions, minimal distributions, Ricci-semi symmetric, geodesibility of lightlike hypersurfaces are obtained. The geometric configuration of lightlike hypersurfaces is established. We prove, under some conditions, that there are no parallel and totally contact umbilical lightlike hypersurfaces of trans-Sasakian space forms, tangent to the structure vector field. We show that there exists a totally umbilical distribution in an Einstein parallel lightlike hypersurface which does not contain the structure vector field. We characterize the normal bundle along any totally contact umbilical leaf of an integrable screen distribution. We finally prove that the geometry of any leaf of an integrable distribution is closely related to the geometry of a normal bundle and its image under φ-bar. (author)

  3. High pulmonary vascular resistance in addition to low right ventricular stroke work index effectively predicts biventricular assist device requirement.

    Science.gov (United States)

    Imamura, Teruhiko; Kinugawa, Koichiro; Kinoshita, Osamu; Nawata, Kan; Ono, Minoru

    2016-03-01

    Although the right ventricular stroke work index (RVSWI) is a good index for RV function, a low RVSWI is not necessarily an indicator for the need for a right ventricular assist device at the time of left VAD implantation. We here aimed to determine a more precise indicator for the need for a biventricular assist device (BiVAD). In total, 116 patients (mean age, 38 ± 14 years), who underwent hemodynamic assessments preoperatively including 12 BiVAD patients, and had been followed at our institute from 2003 to 2015, were included. Multivariate logistic regression analysis indicated that RVSWI and pulmonary vascular resistance (PVR) were independent predictors of BiVAD requirement (P 5 g/m, PVR 5, PVR > 3.7), (3) RV failure (RVSWI 3.7), and examined. Most of the patients in Group 4 (75 %), with acutely depressed hemodynamics and inflammatory responses in the myocardium, required BiVAD. Overall, patients with BiVAD had a worse survival rate as compared with those with LVAD alone. In conclusion, high PVR in addition to low RVSWI effectively predicts BiVAD requirement.

  4. Trans Fat Intake and Its Dietary Sources in General Populations Worldwide: A Systematic Review

    Science.gov (United States)

    Wanders, Anne J.; Zock, Peter L.; Brouwer, Ingeborg A.

    2017-01-01

    After the discovery that trans fat increases the risk of coronary heart disease, trans fat content of foods have considerably changed. The aim of this study was to systematically review available data on intakes of trans fat and its dietary sources in general populations worldwide. Data from national dietary surveys and population studies published from 1995 onward were searched via Scopus and websites of national public health institutes. Relevant data from 29 countries were identified. The most up to date estimates of total trans fat intake ranged from 0.3 to 4.2 percent of total energy intake (En%) across countries. Seven countries had trans fat intakes higher than the World Health Organization recommendation of 1 En%. In 16 out of 21 countries with data on dietary sources, intakes of trans fat from animal sources were higher than that from industrial sources. Time trend data from 20 countries showed substantial declines in industrial trans fat intake since 1995. In conclusion, nowadays, in the majority of countries for which data are available, average trans fat intake is lower than the recommended maximum intake of 1 En%, with intakes from animal sources being higher than from industrial sources. In the past 20 years, substantial reductions in industrial trans fat have been achieved in many countries. PMID:28783062

  5. A estimulação cardíaca convencional é prejudicial em pacientes com função ventricular normal?

    Directory of Open Access Journals (Sweden)

    Luiz Antonio Batista de Sá

    2013-12-01

    Full Text Available FUNDAMENTO: A estimulação de ventrículo direito pode ser deletéria em pacientes com disfunção ventricular, porém, em pacientes com função normal, o impacto desta estimulação desencadeando disfunção ventricular clinicamente relevante não é completamente estabelecido. OBJETIVOS: Avaliar a evolução clínica, ecocardiográfica e laboratorial de pacientes, com função ventricular esquerdapreviamente normal, submetidos a implante de marca-passo. MÉTODO: Estudo observacional transversal em que foram acompanhados de forma prospectiva 20 pacientes submetidos a implante de marca-passo com os seguintes critérios de inclusão: função ventricular esquerda normal definida pelo ecocardiograma e estimulação ventricular superior a 90%. Foram avaliados: classe funcional (CF (New York Heart Association, teste de caminhada de 6 minutos (TC6, dosagem do hormônio natriurético tipo B (BNP, avaliação ecocardiográfica (convencional e parâmetros de dessincronismo e questionário de qualidade de vida (QV (SF-36. A avaliação foi feita com dez dias (t1, quatro meses (t2, oito meses (t3, 12 meses (t4 e 24 meses (t5. RESULTADOS: Os parâmetros ecocardiográficos convencionais e de dessincronismo não apresentaram variação estatística significante ao longo do tempo. O TC6, a CF e a dosagem de BNP apresentaram piora ao final dos dois anos. A QV teve melhora inicial e piora ao final dos dois anos. CONCLUSÃO: O implante de marca-passo convencional foi associado à piora da classe funcional, piora do teste de caminhada, aumento da dosagem de BNP, aumento da duração do QRS e piora em alguns domínios da QV ao final de dois anos. Não houve alterações nas medidas ecocardiográficas (convencionais e medidas de assincronia.

  6. Trans-jugular catheter-directed thrombolysis combined with trans-dorsalis pedis vein thrombolysis for the treatment of deep venous thrombosis of the lower limbs

    International Nuclear Information System (INIS)

    Qian Jiesheng; Li Zhengran; Jiang Zaibo; Zhu Kangshun; Guan Shouhai; Zhou Bing; Xu Changmou; He Keke; Shang Hong

    2009-01-01

    Objective: To investigate the feasibility and efficacy of trans-jugular catheter-directed thrombolysis (CDT) together with trans-dorsalis pedis vein thrombolysis for the treatment of deep venous thrombosis (DVT) of the lower limbs. Methods: Jugular vein puncture, indwelling catheter and placement of IVC filter were performed in 18 patients with DVT (study group) followed by continuous trans-jugular CDT together with trans-dorsalis pedis vein thrombolysis. During the corresponding period, 16 patients with DVT (control group) received trans-dorsalis pedis vein thrombolysis only. Results: The thrombolytic time and total dose of urokinase in study group and control group were (6.6 ± 2.3) days, (5.52 ± 2.24) x 106 units and (8.2 ± 1.4) days, (7.00 ± 1.66) x 106 units respectively. The thrombolytic time and total dose of urokinase in study group were significantly lower than that in control group (P < 0.05). After the treatment the thigh circumference and calf circumference in study group showed a reduction of (4.6 ± 2.1) cm and (4.0 ± 2.1) cm respectively, which were (3.2 ± 1.7) cm and (2.7 ± 1.5) cm respectively in control group, the difference between two groups was statistically significant (P < 0.05). The complete patent of the veins was 66.7% in study group and 31.3% in control group, the difference between two groups was significant (P < 0.05). In four cases of the study group, the filters were withdrawn through the original puncture site after the thrombus was completely dissolved. Conclusion: Trans-jugular CDT combined with trans-dorsalis pedis vein thrombolysis is an effective and safe therapeutic technique for the treatment of deep venous thrombosis of the lower extremities, moreover, the filter can be taken back via the original puncture site when the thrombus is completely dissolved. (authors)

  7. Development of an acoustic measurement protocol to monitor acetabular implant fixation in cementless total hip Arthroplasty: A preliminary study.

    Science.gov (United States)

    Goossens, Quentin; Leuridan, Steven; Henyš, Petr; Roosen, Jorg; Pastrav, Leonard; Mulier, Michiel; Desmet, Wim; Denis, Kathleen; Vander Sloten, Jos

    2017-11-01

    In cementless total hip arthroplasty (THA), the initial stability is obtained by press-fitting the implant in the bone to allow osseointegration for a long term secondary stability. However, finding the insertion endpoint that corresponds to a proper initial stability is currently based on the tactile and auditory experiences of the orthopedic surgeon, which can be challenging. This study presents a novel real-time method based on acoustic signals to monitor the acetabular implant fixation in cementless total hip arthroplasty. Twelve acoustic in vitro experiments were performed on three types of bone models; a simple bone block model, an artificial pelvic model and a cadaveric model. A custom made beam was screwed onto the implant which functioned as a sound enhancer and insertor. At each insertion step an acoustic measurement was performed. A significant acoustic resonance frequency shift was observed during the insertion process for the different bone models; 250 Hz (35%, second bending mode) to 180 Hz (13%, fourth bending mode) for the artificial bone block models and 120 Hz (11%, eighth bending mode) for the artificial pelvis model. No significant frequency shift was observed during the cadaveric experiment due to a lack of implant fixation in this model. This novel diagnostic method shows the potential of using acoustic signals to monitor the implant seating during insertion. Copyright © 2017 IPEM. Published by Elsevier Ltd. All rights reserved.

  8. Research on total-dose hardening for H-gate PD NMOSFET/SIMOX by ion implanting into buried oxide

    International Nuclear Information System (INIS)

    Qian Cong; Zhang Zhengxuan; Zhang Feng; Lin Chenglu

    2008-01-01

    In this work, we investigate the back-gate I-V characteristics for two kinds of NMOSFET/SIMOX transistors with H gate structure fabricated on two different SOI wafers. A transistors are made on the wafer implanted with Si + and then annealed in N 2 , and B transistors are made on the wafer without implantation and annealing. It is demonstrated experimentally that A transistors have much less back-gate threshold voltage shift ΔV th than B transistors under X-ray total close irradiation. Subthreshold charge separation technique is employed to estimate the build-up of oxide charge and interface traps during irradiation, showing that the reduced ΔV th for A transistors is mainly due to its less build-up of oxide charge than B transistors. Photo-luminescence (PL) research indicates that Si implantation results in the formation of silicon nanocrystalline (nanocluster) whose size increases with the implant dose. This structure can trap electrons to compensate the positive charge build-up in the buried oxide during irradiation, and thus reduce the threshold voltage negative shift. (authors)

  9. Pulmonary Arterial Stent Implantation in an Adult with Williams Syndrome

    International Nuclear Information System (INIS)

    Reesink, Herre J.; Henneman, Onno D. F.; Delden, Otto M. van; Biervliet, Jules D.; Kloek, Jaap J.; Reekers, Jim A.; Bresser, Paul

    2007-01-01

    We report a 38-year-old patient who presented with pulmonary hypertension and right ventricular dysfunction due to pulmonary artery stenoses as a manifestation of Williams syndrome, mimicking chronic thromboembolic pulmonary hypertension. The patient was treated with balloon angioplasty and stent implantation. Short-term follow-up showed a good clinical result with excellent patency of the stents but early restenosis of the segments in which only balloon angioplasty was performed. These stenoses were subsequently also treated successfully by stent implantation. Stent patency was observed 3 years after the first procedure

  10. Troponin T elevation after permanent pacemaker implantation.

    Science.gov (United States)

    Chen, Xueying; Yu, Ziqing; Bai, Jin; Hu, Shulan; Wang, Wei; Qin, Shengmei; Wang, Jingfeng; Sun, Zhe; Su, Yangang; Ge, Junbo

    2017-08-01

    The objective of the study is to study the incidence, significance, and factors associated with cardiac troponin T (CTNT) elevation after pacemaker implantation. Three hundred seventy-four patients (104 single-chamber pacemakers or ICD, 243 dual-chamber pacemakers, and 27 cardiac resynchronization therapy/cardiac resynchronization therapy defibrillator) who had normal levels of CTNT at baseline and underwent implantation of a permanent pacemaker system were included in this study. Serum levels of CTNT were measured at baseline, 6 and 24 h after the implantation procedure. The median of CTNT levels increased from 0.012 ng/mL at baseline to 0.032 and 0.019 ng/mL at 6 and 24 h after the procedure, respectively (all p 0.09 ng/mL). After 1-year follow-up, the incidence of complications including dislodgement of the lead, pocket infection, pneumothorax, hemothorax, and vein thrombus and cardiac outcomes including hospitalization of heart failure, coronary artery disease, arrhythmia, and cardiovascular mortality was not significantly different between the normal and elevated CTNT groups at 6 h after the procedure. By logistic regression analysis, gender, N-terminal pro-B type natriuretic peptide (NT-pro-BNP) at baseline, left ventricular ejection fractions (LVEF), estimated glomerular filtration rate (eGFR), and fluoroscopy time were independently associated with CTNT elevation after adjusted for age, pacemaker types, right ventricle lead location (RVA or RVOT), heart function, and left ventricular end systolic dimension. Pacemaker implantation was found to be accompanied with CTNT elevation in 55.6% of the patients at 6 h after the procedure, and its kinetics were fast, which might not be related to the complications and adverse cardiac outcomes within 1 year of follow-up. Moreover, gender, NT-pro-BNP at baseline, LVEF, eGFR, and fluoroscopy time were found to be independent predictors of CTNT elevation.

  11. Aortic valve replacement and prosthesis-patient mismatch in the era of trans-catheter aortic valve implantation.

    Science.gov (United States)

    Morita, Shigeki

    2016-08-01

    The treatment strategy for aortic stenosis (AS) has been changing due to newly developed valvular prostheses and trans-catheter aortic valve implantation (TAVI). To determine the role of new modalities for AS with a small aortic root, papers using the concept of prosthesis-patient mismatch (PPM) were reviewed. First, to determine the cut-off value of the indexed effective orifice area (IEOA) for defining PPM, the studies of surgical aortic valve replacement (SAVR) with a follow-up longer than 5 years and a patient number larger than 500 were reviewed. Second, the papers comparing TAVI and SAVR were reviewed. Furthermore, the prevalence of PPM was reviewed, with the addition of papers on aortic root enlargement, sutureless AVR, and aortic valve reconstruction with autologous pericardium. The results of the long-term survival after aortic valve replacement (AVR) have indicated that an IEOA less than 0.65 cm(2)/m(2) should be avoided in all cases, whereas the indications for patients with an IEOA between 065 and 0.85 cm(2)/m(2) should be determined by considering multiple factors. A large body size and younger age have a significantly negative influence on the long-term survival. In Asian population, the prevalence of PPM was low, despite the fact that the size of the aortic annulus was small. The IEOA after TAVI was larger than after surgical AVR in population-matched studies. To evaluate the role of TAVI and other modalities for a small aortic root, studies with a longer follow-up and larger volume are thus warranted.

  12. Energy transmission and power sources for mechanical circulatory support devices to achieve total implantability.

    Science.gov (United States)

    Wang, Jake X; Smith, Joshua R; Bonde, Pramod

    2014-04-01

    Left ventricular assist device therapy has radically improved congestive heart failure survival with smaller rotary pumps. The driveline used to power today's left ventricular assist devices, however, continues to be a source of infection, traumatic damage, and rehospitalization. Previous attempts to wirelessly power left ventricular assist devices using transcutaneous energy transfer systems have been limited by restrictions on separation distance and alignment between the transmit and receive coils. Resonant electrical energy transfer allows power delivery at larger distances without compromising safety and efficiency. This review covers the efforts to wirelessly power mechanical circulatory assist devices and the progress made in enhancing their energy sources. Copyright © 2014 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  13. Dietary trans-fatty acids and metabolic syndrome

    Directory of Open Access Journals (Sweden)

    Zdzisław Kochan

    2010-12-01

    Full Text Available Trans-fatty acids (TFAs, products of partial hydrogenation of vegetable oils, have become more prevalent in our diet since the 1960s, when they replaced animal fats. TFAs also occur naturally in meat and dairy products from ruminants. There is growing evidence that dietary trans-fatty acids may increase the risk of metabolic syndrome. Several studies have demonstrated adverse effects of TFAs on plasma lipids and lipoproteins. In dietary trials, trans-fatty acids have been shown to raise the total cholesterol/HDL cholesterol ratio and Lp(a levels in blood. Moreover, a high intake of TFAs has been associated with an increased risk of coronary heart disease. Prospective cohort studies have shown that dietary trans-fatty acids promote abdominal obesity and weight gain. In addition, it appears that TFA consumption may be associated with the development of insulin resistance and type 2 diabetes. The documented adverse health effects of TFAs emphasise the importance of efforts to reduce the content of partially hydrogenated vegetable oils in foods.

  14. The management of patients with aortic regurgitation and severe left ventricular dysfunction: a systematic review.

    Science.gov (United States)

    Badar, Athar A; Brunton, Alan P T; Mahmood, Ammad H; Dobbin, Stephen; Pozzi, Andrea; McMinn, Jenna F; Sinclair, Andrew J E; Gardner, Roy S; Petrie, Mark C; Curry, Phil A; Al-Attar, Nawwar H K; Pettit, Stephen J

    2015-01-01

    A systematic search of Medline, EMBASE and CINAHL electronic databases was performed. Original research articles reporting all-cause mortality following surgery in patients with aortic regurgitation and severe left ventricular systolic dysfunction (LVSD) were identified. Nine of the 10 eligible studies were observational, single-center, retrospective analyses. Survival ranged from 86 to 100% at 30 days; 81 to 100% at 1 year and 68 to 84% at 5 years. Three studies described an improvement in mean left ventricular ejection fraction (LVEF) following aortic valve replacement (AVR) of 5-14%; a fourth study reported an increase in mean left ventricular ejection fraction (LVEF) of 9% in patients undergoing isolated AVR but not when AVR was combined with coronary artery bypass graft and/or mitral valve surgery. Three studies demonstrated improvements in functional New York Heart Association (NYHA) class following AVR. Additional studies are needed to clarify the benefits of AVR in patients with more extreme degrees of left ventricular systolic dysfunction (LVSD) and the potential roles of cardiac transplantation and transaortic valve implantation.

  15. Anatomy of the bovine ascending aorta and brachiocephalic artery found unfavorable for total artificial heart implant.

    Science.gov (United States)

    Karimov, Jamshid H; Sunagawa, Gengo; Such, Kimberly A; Sale, Shiva; Golding, Leonard A R; Moazami, Nader; Fukamachi, Kiyotaka

    2015-12-01

    The biocompatibility assessment of the Cleveland Clinic continuous-flow total artificial heart is an important part of the device developmental program. Surgical and postoperative management are key factors in achieving optimal outcomes. However, the presence of vascular anatomical abnormalities in experimental animal models is often unpredictable and may worsen the expected outcomes. We report a technical impediment encountered during total artificial heart implantation complicated by unfavorable bovine anatomy of the ascending aorta and brachiocephalic arterial trunk.

  16. Risk of pacemaker or implantable cardioverter defibrillator after radiotherapy for early-stage breast cancer in Denmark, 1982-2005

    DEFF Research Database (Denmark)

    Rehammar, Jens Christian; Johansen, Jens Brock; Jensen, Maj-Britt

    2017-01-01

    BACKGROUND AND PURPOSE: To examine the risk of cardiac conduction abnormalities or severe ventricular arrhythmias requiring implantation of a cardiac implantable electronic device (CIED), either a pacemaker or an implantable cardioverter-defibrillator, subsequent to breast cancer (BC) radiotherapy...... (RT). MATERIAL AND METHODS: All women treated for early-stage BC in Denmark from 1982 to 2005 were identified from the Danish Breast Cancer Cooperative Group. By record linkage to the Danish Pacemaker and ICD Registry information was retrieved on CIED implants subsequent to RT. Standardized incidence...

  17. Trans Fat Intake and Its Dietary Sources in General Populations Worldwide: A Systematic Review

    Directory of Open Access Journals (Sweden)

    Anne J. Wanders

    2017-08-01

    Full Text Available After the discovery that trans fat increases the risk of coronary heart disease, trans fat content of foods have considerably changed. The aim of this study was to systematically review available data on intakes of trans fat and its dietary sources in general populations worldwide. Data from national dietary surveys and population studies published from 1995 onward were searched via Scopus and websites of national public health institutes. Relevant data from 29 countries were identified. The most up to date estimates of total trans fat intake ranged from 0.3 to 4.2 percent of total energy intake (En% across countries. Seven countries had trans fat intakes higher than the World Health Organization recommendation of 1 En%. In 16 out of 21 countries with data on dietary sources, intakes of trans fat from animal sources were higher than that from industrial sources. Time trend data from 20 countries showed substantial declines in industrial trans fat intake since 1995. In conclusion, nowadays, in the majority of countries for which data are available, average trans fat intake is lower than the recommended maximum intake of 1 En%, with intakes from animal sources being higher than from industrial sources. In the past 20 years, substantial reductions in industrial trans fat have been achieved in many countries.

  18. Left Ventricular Assist Devices: The Adolescence of a Disruptive Technology.

    Science.gov (United States)

    Pinney, Sean P

    2015-10-01

    Clinical outcomes for patients with advanced heart failure receiving left ventricular assist devices are driven by appropriate patient selection, refined surgical technique, and coordinated medical care. Perhaps even more important is innovative pump design. The introduction and widespread adoption of continuous-flow ventricular assist devices has led to a paradigm shift within the field of mechanical circulatory support, making the promise of lifetime device therapy closer to reality. The disruption caused by this new technology, on the one hand, produced meaningful improvements in patient survival and quality of life, but also introduced new clinical challenges, such as bleeding, pump thrombosis, and acquired valvular heart disease. Further evolution within this field will require financial investment to sustain innovation leading to a fully implantable, durable, and cost-effective pump for a larger segment of patients with advanced heart failure. Copyright © 2015 Elsevier Inc. All rights reserved.

  19. Percutaneous Implantation of A Parachute Device For Treatment of Ischemic Heart Failure

    Energy Technology Data Exchange (ETDEWEB)

    Cilingiroglu, Mehmet, E-mail: mcilingiroglu@yahoo.com; Rollefson, William A.; Mego, David

    2013-07-15

    Congestive heart failure (CHF) secondary to ischemic cardiomyopathy is associated with significant morbidity and mortality despite currently available medical therapy. The Parachute{sup TM} device is a novel left ventricular partitioning device that is delivered percutaneously in the left ventricle (LV) in patients with anteroapical regional wall motion abnormalities, dilated LV and systolic dysfunction after anterior myocardial infarction with favorable clinical and LV hemodynamic improvements post-implantation. Here, we do review the current literature and present a case of the Parachute device implantation.

  20. Percutaneous Implantation of A Parachute Device For Treatment of Ischemic Heart Failure

    International Nuclear Information System (INIS)

    Cilingiroglu, Mehmet; Rollefson, William A.; Mego, David

    2013-01-01

    Congestive heart failure (CHF) secondary to ischemic cardiomyopathy is associated with significant morbidity and mortality despite currently available medical therapy. The Parachute TM device is a novel left ventricular partitioning device that is delivered percutaneously in the left ventricle (LV) in patients with anteroapical regional wall motion abnormalities, dilated LV and systolic dysfunction after anterior myocardial infarction with favorable clinical and LV hemodynamic improvements post-implantation. Here, we do review the current literature and present a case of the Parachute device implantation

  1. Evaluation of a novel ventricular support device with defibrillation capabilities in canine and porcine animal models.

    Science.gov (United States)

    Killingsworth, Cheryl R; Rippy, Marian K; Virmani, Renu; Rollins, Dennis L; McGiffin, David C; Ideker, Raymond E

    2008-08-01

    Sudden death is prevalent in heart failure patients. We tested an implantable ventricular support device consisting of a wireform harness with one or two pairs of integrated defibrillation electrode coils. The device was implanted into six pigs (36-44 kg) through a subxiphoid incision. Peak voltage (V) defibrillation thresholds (DFT) were determined for five test configurations compared with a control transvenous lead (RV to CanPect). Defibrillator can location (abdominal or pectoral) and common coil separation on the implant (0 degrees or 60 degrees ) were studied.(.) The DFT for RV60 to LV60 + CanPect was significantly less than control (348 +/- 57 vs 473 +/- 27 V, P < 0.05). The DFTs for other vectors were similar to control except for RV0 to LV0 + CanAbd (608 +/- 159 V). The device was implanted into 12 adult dogs for 42, 90, or 180 days with DFT and pathological examination performed at the terminal study. Cardiac pressures were determined at baseline, after implantation, and at the terminal study. The DFT was also determined in a separate group of four dogs at 42 days following implantation of the support device with one pair of defibrillation electrodes. The DFTs at implant and explant in dogs with one pair (8 +/- 1.5 Joules [J] and 6 +/- 1.9 J) or two pairs (8 +/- 3.4 J and 7 +/- 1.9 J) of defibrillation electrodes were not significantly different from each other but significantly less than control measured at the terminal study (18 +/- 3.4 J). Left-sided pressures were significantly decreased at explant but within expected normal ranges. Right-sided pressures were not different except for RV systolic. Histopathology indicated mild to moderate epicardial inflammation and fibrosis, consistent with a foreign body healing response. This defibrillation-enabled ventricular support system maintained mechanical functionality for up to 6 months while inducing typical chronic healing responses. The DFT was equal to or lower than a standard transvenous vector.

  2. A case of appropriate inappropriate device therapy: Hyperkalemia-induced ventricular oversensing

    OpenAIRE

    Oudit, Gavin Y; Cameron, Doug; Harris, Louise

    2008-01-01

    The present case describes a patient who received inappropriate, but potentially life-saving, therapy from her implantable cardioverter defibrillator (ICD) in the setting of acute hyperkalemia (plasma potassium concentration = 8 mM). Hyperkalemia was associated with the development of a slow sinusoidal ventricular tachycardia, at a rate of 100 beats/min to 125 beats/min (610 ms to 480 ms) in a patient who is pacemaker-dependent. There was associated fractionation of the ICD electrogram and T ...

  3. Usefulness of implantable loop recorder in a patient with syncope during bathing

    Directory of Open Access Journals (Sweden)

    Motohiro Nakao, MD

    2013-02-01

    Full Text Available A 27-year-old man presented to our hospital with a 1-year-hisory of repeated syncope, which particularly occurred while bathing or on a hot day. The head-up tilt test did not induce arrhythmia; however, blood pressure decreased by 39 mm Hg without any symptoms. Given that no bradycardia/tachycardia was induced on electrophysiological study and carotid sinus massage, an implantable loop recorder (ILR was implanted. After 2 months, syncope again occurred during bathing at midnight. Sinus arrest and a maximum ventricular pause of 10.2 s were documented using the ILR. After pacemaker implantation, the patient had not experienced syncope for 14 months.

  4. Concerns about the implantable cardioverter defibrillator

    DEFF Research Database (Denmark)

    Pedersen, Susanne S.; van Domburg, Ron T; Theuns, Dominic A M J

    2005-01-01

    Patients with an implantable cardioverter defibrillator (ICD) are at increased risk of anxiety disorders. In turn, anxiety has been identified as a precipitant of ventricular arrhythmias. Anxiety may in part be attributed to concerns about the ICD firing, but the relationship between ICD concerns......, psychological morbidity, and shocks has not been systematically investigated. We examined the relative importance of experienced shocks versus subjective concerns about the ICD as determinants of anxiety and depressive symptoms in ICD patients....

  5. Trans fatty acid isomers and the trans-9/trans-11 index in fat containing foods

    Science.gov (United States)

    Kuhnt, Katrin; Baehr, Melanie; Rohrer, Carsten; Jahreis, Gerhard

    2011-01-01

    To determine trans fatty acid (TFA) distribution of contemporary foods, especially regarding individual trans octadecenoic acids (trans C18:1), 339 German foods of six categories (semi-solid fats, deep-fried potato products, bakery products, confectioneries, instant products and butter) were analysed using two GC methods. Results showed a high variation of TFA content between and within the categories containing between 0 and 40.5% of FAME except in butter, which is a source of natural TFA. The mean TFA values were below 2.0% of FAME, however, bakery products contained 4.5% and butter fat 3.2%, respectively. In addition, the distribution of individual trans C18:1 differed. In samples containing ruminant fat (butter and various confectioneries), vaccenic acid (t11-C18:1, t11) predominated, while in foods containing industrially hydrogenated fats, elaidic acid (trans-9, t9-) and t10-C18:1 were the major trans isomers.. This was reflected by a low t9/t11 index of 0.3 and 0.5 in butter and ruminant fat containing confectioneries, respectively, whilst the highest index was observed in shortenings and deep-fried potato products at 5.2 and 6.8, respectively. In conclusion, the TFA content of foods available on the German market is generally declining, but substantial variations are present. The t9/t11 index could be used as an indicator to determine ruminant fat. Practical applications: A number of studies provide evidence that a high TFA intake, particularly of industrial origin, adversely affects human health. The TFA content of foods could be reduced due to the introduction of several mandatory regulations and modifications regarding the hydrogenation process of oils. The most abundant dietary TFA are the isomers of trans C18:1. Unfortunately, the differentiation of these isomers is not yet very common, though the trans C18:1 profile differs depending on its origin (bacterial hydrogenation in the rumen or industrial hydrogenation). To date, data for TFA content

  6. Computer-navigated minimally invasive total knee arthroplasty for patients with retained implants in the femur

    Directory of Open Access Journals (Sweden)

    Sung-Yen Lin

    2014-08-01

    Full Text Available Total knee arthroplasty (TKA in patients with knee arthritis and retained implants in the ipsilateral femur is a challenge for knee surgeons. Use of a conventional intramedullary femoral cutting guide is not practical because of the obstruction of the medullary canal by implants. Previous studies have shown that computer-assisted surgery (CAS can help restore alignment in conventional TKA for patients with knee arthritis with retained femoral implants or extra-articular deformity, without the need for implant removal or osteotomy. However, little has been published regarding outcomes with the use of navigation in minimally invasive surgery (MIS-TKA for patients with this complex knee arthritis. MIS has been proven to provide less postoperative pain and faster recovery than conventional TKA, but MIS-TKA in patients with retained femoral implants poses a greater risk in limb malalignment. The purpose of this study is to report the outcome of CAS-MIS-TKA in patients with knee arthritis and retained femoral implants. Between April 2006 and March 2008, eight patients with knee arthritis and retained femoral implants who underwent the CAS-MIS-TKA were retrospectively reviewed. Three of the eight patients had extra-articular deformity, including two femur bones and one tibia bone, in the preoperative examination. The anteroposterior, lateral, and long-leg weight-bearing radiographs carried out at 3-month follow-up was used to determine the mechanical axis of lower limb and the position of components. The mean preoperative femorotibial angle in patients without extra-articular deformity was 3.8° of varus and was corrected to 4.6° of valgus. With the use of navigation in MIS-TKA, the two patients in this study with extra-articular femoral deformity also obtained an ideal postoperative mechanical axis within 2° of normal alignment. Overall, there was a good restoration of postoperative mechanical alignment in all cases, with a mean angle of 0.4° of

  7. Surgical ablation of ventricular tachycardia secondary to congenital ventricular septal aneurysm.

    Science.gov (United States)

    Graffigna, A; Minzioni, G; Ressia, L; Vigano, M

    1994-04-01

    Three patients underwent surgical ablation for ventricular tachycardia resulting from an aneurysm of the membranous portion of the ventricular septum. Two patients had a definite history of cardiac murmur during infancy, and one of them was found at the time of operation to have a left-to-right shunt through the apex of the aneurysm. The earliest ventricular activation sites were located around the neck of the aneurysm and were ablated in 1 patient by encircling the endocardial ventriculotomy and by cryoablation in the remaining 2. After focus resection had been completed, aneurysm resection and ventricular septal reconstruction were performed. All patients were alive and free of ventricular tachycardia and did not need medication as of 61, 66, and 88 months postoperatively. Spontaneous closure of a ventricular septal defect may lead to the formation of an aneurysm in the ventricular septum that may sustain ventricular tachycardias. Such arrhythmias can be effectively treated using electrically guided surgical techniques.

  8. Totally implantable vascular access device (TIVAD) placement: a modified technique that takes post-procedure aesthetic aspects into account.

    Science.gov (United States)

    Liberale, Gabriel

    2017-04-01

    Major progress has been made in breast cancer reconstruction surgery. The standard technique for totally implanted vascular access device (TIVAD) implantation generally requires an incision for port insertion on the anterior part of the thorax that leaves a scar in the middle of the neckline in patients who have undergone mastectomy with complex breast reconstruction. The aim of this technical note is to report our revised surgical technique for TIVAD placement. In patients with breast cancer, we take a lateralized approach, performing an oblique incision on the lowest part of the deltopectoral groove. This allows us to introduce the port and to place it on the anterolateral part of the thorax, thus avoiding an unaesthetic scar on the anterior part of the thorax. Our modified technique for TIVAD implantation is described.

  9. Trans-Planckian wimpzillas

    CERN Document Server

    Kolb, E W; Tkachev, I I

    2007-01-01

    Two previously proposed conjectures--gravitational trans-Planckian particle creation in the expanding universe, and the existence of ultra-heavy stable particles with masses up to the Planck scale (wimpzillas)--are combined in a proposal for trans-Planckian particle creation of wimpzillas. It is shown that the trans-Planckian particle creation parameter should be rather small to avoid overproduction of such particles. This ensures that wimpzillas are mainly created at the end of primordial inflation. Conditions under which trans-Planckian wimpzillas can constitute the present dark matter are determined.

  10. Pathology in patients with ventricular assist devices: a study of 21 autopsies, 24 ventricular apical core biopsies and 24 explanted hearts.

    Science.gov (United States)

    Rose, Alan G; Park, Soon J

    2005-01-01

    Ventricular assist devices (VADs) are used as a bridge to cardiac transplantation or as a permanent or sometimes temporary treatment for end stage heart failure. Our autopsy and surgical pathology experience with VADs prior to August 2002 was reviewed. Noted were patient's age, sex, underlying (UCOD) and proximate causes of death (PCOD), duration of VAD implantation, presence of native or prosthetic valvar disease and organ complications. Myocardium from biopsies and explanted hearts were blindly assessed for coagulative necrosis (CN), contraction bands (CB), myocytolysis (MC), increased eosinophilia (IE), myocyte waviness (MW) and fibrosis (F). Each was graded as either mild (score 1), moderate (score 2) or severe (score 3). Autopsy patients: Twenty-one patients, with mean age 55 years (range 10-73), comprised 10 women and 11 men. UCOD was ischemic disease in 16 patients, dilated cardiomyopathy in 4 and aortic valve disease in 1. The mean duration of VAD implantation was 125.7 days (range 1-1095 days, S.D.=253.6). Five patients had biventricular VADs, and 16 had LVAD only. Acquired aortic valve fusion was noted in three patients. PCOD was VAD related in six, donor heart problem in four, cerebrovascular accident in four, miscellaneous in three, pulmonary hypertension in two and aortic disease in two patients. Morbidity: local liver necrosis in seven, acquired aortic valve disease in four, gut infarction in three, abdominal aortic aneurysm in two and host cell assault against VAD porcine aortic valves in one case. Biopsies and explanted hearts: Twenty-four patients had a mean age of 53 years (range 38-68, S.D.=8.6). VADs were implanted for 177.8 days (range 7-593 days, S.D.=151.1). Comparison of histologic scores of biopsies with explanted hearts showed the following: CN 1.33 (S.D.=1.4)/0.21 (S.D.=0.66; P<.001); CB: 2.1 (S.D.=0.93)/0.83 (S.D.=0.28; NS); MC: 0.88 (S.D.=1.19)/0.13 (S.D.=0.34; P<.01); IE: 1.71 (S.D.=1.27)/0.38 (S.D.=0.65; NS); fibrosis: 1.08 (S.D.=1

  11. [Total artificial heart].

    Science.gov (United States)

    Antretter, H; Dumfarth, J; Höfer, D

    2015-09-01

    To date the CardioWest™ total artificial heart is the only clinically available implantable biventricular mechanical replacement for irreversible cardiac failure. This article presents the indications, contraindications, implantation procedere and postoperative treatment. In addition to a overview of the applications of the total artificial heart this article gives a brief presentation of the two patients treated in our department with the CardioWest™. The clinical course, postoperative rehabilitation, device-related complications and control mechanisms are presented. The total artificial heart is a reliable implant for treating critically ill patients with irreversible cardiogenic shock. A bridge to transplantation is feasible with excellent results.

  12. Effect of Trans, Trans-Farnesol on Pseudogymnoascus destructans and Several Closely Related Species.

    Science.gov (United States)

    Raudabaugh, Daniel B; Miller, Andrew N

    2015-12-01

    Bat white-nose syndrome, caused by the psychrophilic fungus Pseudogymnoascus destructans, has dramatically reduced the populations of many hibernating North American bat species. The search for effective biological control agents targeting P. destructans is of great importance. We report that the sesquiterpene trans, trans-farnesol, which is also a Candida albicans quorum sensing compound, prevented in vitro conidial germination for at least 14 days and inhibited growth of preexisting hyphae of five P. destructans isolates in filtered potato dextrose broth at 10 °C. Depending on the inoculation concentrations, both spore and hyphal inhibition occurred upon exposure to concentrations as low as 15-20 µM trans, trans-farnesol. In contrast, most North American Pseudogymnoascus isolates were more tolerant to the exposure of trans, trans-farnesol. Our results suggest that some Candida isolates may have the potential to inhibit the growth of P. destructans and that the sesquiterpene trans, trans-farnesol has the potential to be utilized as a biological control agent.

  13. Differential effect of corn oil-based low trans structured fat on the plasma and hepatic lipid profile in an atherogenic mouse model: comparison to hydrogenated trans fat

    Directory of Open Access Journals (Sweden)

    Kim Hye-Jin

    2011-01-01

    Full Text Available Abstract Background Trans fat are not desirable in many aspects on health maintenance. Low trans structured fats have been reported to be relatively more safe than trans fats. Methods We examined the effects of low trans structured fat from corn oil (LC, compared with high trans fat shortening, on cholesterol and fatty acid metabolism in apo E deficient mice which is an atherogenic animal model. The animals were fed a high trans fat (10% fat: commercial shortening (CS or a low trans fat (LC diet for 12 weeks. Results LC decreased apo B and hepatic cholesterol and triglyceride concentration compared to the CS group but significantly increased plasma total cholesterol and triglyceride concentration and fecal lipids with a simultaneous increase in HDL-cholesterol level, apo A-I, and the ratio of HDL-cholesterol to total cholesterol (HTR. Reduction of hepatic lipid levels by inclusion of LC intake was observed alongside modulation of hepatic enzyme activities related to cholesterol esterification, fatty acid metabolism and fecal lipids level compared to the CS group. The differential effects of LC intake on the plasma and hepatic lipid profile seemed to be partly due to the fatty acid composition of LC which contains higher MUFA, PUFA and SFA content as well as lower content of trans fatty acids compared to CS. Conclusions We suggest that LC may exert a dual effect on plasma and hepatic lipid metabolism in an atherogenic animal model. Accordingly, LC, supplemented at 10% in diet, had an anti-atherogenic effect on these apo E-/- mice, and increased fecal lipids, decreased hepatic steatosis, but elevated plasma lipids. Further studies are needed to verify the exact mode of action regarding the complex physiological changes and alteration in lipid metabolism caused by LC.

  14. Differential effect of corn oil-based low trans structured fat on the plasma and hepatic lipid profile in an atherogenic mouse model: comparison to hydrogenated trans fat

    Science.gov (United States)

    2011-01-01

    Background Trans fat are not desirable in many aspects on health maintenance. Low trans structured fats have been reported to be relatively more safe than trans fats. Methods We examined the effects of low trans structured fat from corn oil (LC), compared with high trans fat shortening, on cholesterol and fatty acid metabolism in apo E deficient mice which is an atherogenic animal model. The animals were fed a high trans fat (10% fat: commercial shortening (CS)) or a low trans fat (LC) diet for 12 weeks. Results LC decreased apo B and hepatic cholesterol and triglyceride concentration compared to the CS group but significantly increased plasma total cholesterol and triglyceride concentration and fecal lipids with a simultaneous increase in HDL-cholesterol level, apo A-I, and the ratio of HDL-cholesterol to total cholesterol (HTR). Reduction of hepatic lipid levels by inclusion of LC intake was observed alongside modulation of hepatic enzyme activities related to cholesterol esterification, fatty acid metabolism and fecal lipids level compared to the CS group. The differential effects of LC intake on the plasma and hepatic lipid profile seemed to be partly due to the fatty acid composition of LC which contains higher MUFA, PUFA and SFA content as well as lower content of trans fatty acids compared to CS. Conclusions We suggest that LC may exert a dual effect on plasma and hepatic lipid metabolism in an atherogenic animal model. Accordingly, LC, supplemented at 10% in diet, had an anti-atherogenic effect on these apo E-/- mice, and increased fecal lipids, decreased hepatic steatosis, but elevated plasma lipids. Further studies are needed to verify the exact mode of action regarding the complex physiological changes and alteration in lipid metabolism caused by LC. PMID:21247503

  15. Impact of Vice President Cheney on public interest in left ventricular assist devices and heart transplantation.

    Science.gov (United States)

    Pandey, Ambarish; Abdullah, Kazeen; Drazner, Mark H

    2014-05-01

    Although celebrity illnesses attract a significant amount of media attention in the United States, there are few studies that have looked at how celebrity health conditions impact the awareness of the illness in the general population. Recently, Vice President Cheney underwent left ventricular assist device (LVAD) implantation and subsequently a cardiac transplant. The aim of this study was to determine whether there was evidence of increased interest in these 2 procedures as assessed by social media. We determined the relative frequency of Google searches for LVAD and heart transplantation from 2004 to 2013 using Google trends. We also counted the number of YouTube videos and Twitter messages posted monthly concerning LVADs over a 7-year time frame. There was a significant spike in the Google search interest for LVAD and heart transplantation in the month when Vice President Cheney underwent the respective procedure. Similarly, there was a large increase in YouTube videos and Twitter messages concerning LVADs shortly after he was implanted. In total, these data support the concept that a public figure's illness can significantly influence the public's interest in that condition and its associated therapies. Copyright © 2014 Elsevier Inc. All rights reserved.

  16. Assessment of inter-atrial, inter-ventricular, and atrio-ventricular interactions in tetralogy of Fallot patients after surgical correction. Insights from two-dimensional speckle tracking and three-dimensional echocardiography.

    Science.gov (United States)

    Abd El Rahman, Mohamed; Raedle-Hurst, Tanja; Rentzsch, Axel; Schäfers, Hans-Joachim; Abdul-Khaliq, Hashim

    2015-10-01

    We aimed to assess biatrial size and function, interactions on atrial and ventricular levels, and atrio-ventricular coupling in patients after tetralogy of Fallot repair. A total of 34 patients with a mean age of 20.9±9 years, and 35 healthy controls, underwent two-dimensional speckle tracking echocardiography for ventricular and atrial strain measurements and real-time three-dimensional echocardiography to assess ventricular and atrial volumes. When compared with controls, tetralogy of Fallot patients had significantly reduced right atrial peak atrial longitudinal strain (ptetralogy of Fallot group, left ventricular ejection fraction was negatively related to the right ventricular end-systolic volume normalised to body surface area (r=-0.62, ptetralogy of Fallot patients, biatrial dysfunction exists and can be quantified via two-dimensional speckle tracking echocardiography as well as real-time three-dimensional echocardiography. Different forms of interactions on atrial and ventricular levels are evident among such cohorts.

  17. Battery longevity in cardiac resynchronization therapy implantable cardioverter defibrillators.

    Science.gov (United States)

    Alam, Mian Bilal; Munir, Muhammad Bilal; Rattan, Rohit; Flanigan, Susan; Adelstein, Evan; Jain, Sandeep; Saba, Samir

    2014-02-01

    Cardiac resynchronization therapy (CRT) implantable cardioverter defibrillators (ICDs) deliver high burden ventricular pacing to heart failure patients, which has a significant effect on battery longevity. The aim of this study was to investigate whether battery longevity is comparable for CRT-ICDs from different manufacturers in a contemporary cohort of patients. All the CRT-ICDs implanted at our institution from 1 January 2008 to 31 December 2010 were included in this analysis. Baseline demographic and clinical data were collected on all patients using the electronic medical record. Detailed device information was collected on all patients from scanned device printouts obtained during routine follow-up. The primary endpoint was device replacement for battery reaching the elective replacement indicator (ERI). A total of 646 patients (age 69 ± 13 years), implanted with CRT-ICDs (Boston Scientific 173, Medtronic 416, and St Jude Medical 57) were included in this analysis. During 2.7 ± 1.5 years follow-up, 113 (17%) devices had reached ERI (Boston scientific 4%, Medtronic 25%, and St Jude Medical 7%, P battery was significantly worse for Medtronic devices compared with devices from other manufacturers (94% for Boston scientific, 67% for Medtronic, and 92% for St Jude Medical, P battery longevity by manufacturer was independent of pacing burden, lead parameters, and burden of ICD therapy. There are significant discrepancies in CRT-ICD battery longevity by manufacturer. These data have important implications on clinical practice and patient outcomes.

  18. Demikhov's "Mechanical Heart": The Circumstances Surrounding Creation of the World's First Implantable Total Artificial Heart in 1937.

    Science.gov (United States)

    Glyantsev, Sergey P; Tchantchaleishvili, Vakhtang; Bockeria, Leo A

    2016-01-01

    The world's first implantable total artificial heart was designed by Vladimir Demikhov as a fourth year biology student in Voronezh, Soviet Union, in 1937. As a prototype of his device, Demikhov must have used an apparatus for extracorporeal blood circulation invented by Sergei Bryukhonenko of Moscow. The device was the size of a dog's native heart and consisted of two diaphragm pumps brought into motion by an electric motor. A dog with an implanted device lived for 2.5 hours. In addition to having the prototype, the preconditions for Demikhov's artificial heart creation were his manual dexterity, expertise in animal physiology, and his mechanistic worldview.

  19. Inappropriate shock delivery by implantable cardioverter defibrillator due to electrical interference with washing machine.

    Science.gov (United States)

    Chongtham, Dhanaraj Singh; Bahl, Ajay; Kumar, Rohit Manoj; Talwar, K K

    2007-05-31

    We report a patient with hypertrophic cardiomyopathy who received an inappropriate implantable cardioverter defibrillator shock due to electrical interference from a washing machine. This electrical interference was detected as an episode of ventricular fibrillation with delivery of shock without warning symptoms.

  20. Ventricular arrhythmias and sudden cardiac arrest in Takotsubo cardiomyopathy: Incidence, predictive factors, and clinical implications.

    Science.gov (United States)

    Jesel, Laurence; Berthon, Charlotte; Messas, Nathan; Lim, Han S; Girardey, Mélanie; Marzak, Halim; Marchandot, Benjamin; Trinh, Annie; Ohlmann, Patrick; Morel, Olivier

    2018-04-06

    Takotsubo cardiomyopathy (TTC) is a stress-related transient cardiomyopathy. Life-threatening arrhythmias (LTA) can occur and worsen prognosis. The purpose of this study was to assess the incidence and outcome of LTA in TTC, as well as its predictive factors and clinical implications. We studied 214 consecutive cases of TTC over 8 years. The study cohort was divided into 2 groups: those with LTA (LTA group) and those without (non-LTA group). LTA was defined as ventricular tachycardia, ventricular fibrillation, or cardiac arrest. LTA occurred in 10.7% of patients mainly in the first 24 hours of hospitalization: ventricular tachycardia (n = 2), ventricular fibrillation (n = 11), cardiac arrest (n = 10: 5 asystole, 3 complete heart block, and 2 sinoatrial block). LTA were associated with lower left ventricular ejection fraction (LVEF) and a high rate of conduction disturbances. In-hospital (39.1% vs 8.9%; P 105 ms were independent predictors of LTA. In cases where a device was implanted, conduction disturbances persisted after the index event despite complete recovery of LVEF. There was no ventricular arrhythmia recurrence during follow-up. LTA occur early in patients presenting with TTC and is associated with significantly worse short- and long-term prognosis. Left ventricular impairment and QRS duration >105 ms are independent predictors of LTA. Ventricular arrhythmias occurred in the acute phase without further recurrence recorded in hospital survivors, whereas severe conduction disorders persisted during long-term follow-up. These findings may have implications on the choice of device therapy for this specific patient subgroup. Copyright © 2018 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  1. Trans trochanteric approach with coronal osteotomy of the great trochanter: A new technique for extra-capsular trochanteric fracture patients treated by total hip arthroplasty (THA) in elderly.

    Science.gov (United States)

    Steffann, Francois; Prudhon, Jean-Louis; Puch, Jean-Marc; Ferreira, André; Descamps, Loys; Verdier, Régis; Caton, Jacques

    2015-06-05

    Several surgical approaches could be used in hip arthroplasty or trauma surgery: anterior, anterolateral, lateral, posterior (with or without trochanterotomy), using or not an orthopedic reduction table. Subtrochanteric and extra-capsular trochanteric fractures (ECTF) are usually treated by internal fixation with mandatory restrictions on weight bearing. Specific complications have been widely described. Mechanical failures are particularly high in unstable fractures. Hip fractures are a major public health issue with a mortality rate of 12%-23% at 1 year. An alternative option is to treat ECTF by total hip arthroplasty (THA) to prevent decubitus complications, to help rapid recovery, and to permit immediate weight bearing as well as quick rehabilitation. However, specific risks of THA have to be considered such as dislocation or cardiovascular failure. The classical approach (anterior or posterior) requires the opening of the joint and capsule, weakening hip stability and the repair of the great trochanter is sometimes hazardous. For 15 years, we have been treating unstable ECTF by THA with cementless stem, dual mobility cup (DMC), greater trochanter (GT) reattachment, and a new surgical approach preserving capsule, going through the fracture and avoiding joint dislocation. Bombaci first described a similar approach in 2008; our trans fractural digastric approach (medial gluteus and lateral vastus) is different. A coronal GT osteotomy is performed when there is no coronal fracture line. It allows easy access to the femoral neck and acetabulum. The THA is implanted without femoral internal rotation to avoid extra bone fragment displacement. With pre-operative planning, cup implantation is easy and stem positioning is adjusted referring to the top of the GT after trial reduction and preoperative planning. The longitudinal osteotomy and trochanteric fracture are repaired with wires and the digastric incision is closed. This variant of Bombaci approach could be use

  2. Usefulness of Totally Implantable Central Venous Access Devices in Elderly Patients: A Retrospective Study.

    Science.gov (United States)

    Imaoka, Yuki; Kuranishi, Fumito; Ogawa, Yoshiteru

    2018-01-01

    The need for totally implantable central venous access devices (TICVADs) has increased with increased opportunities in the use of chemotherapy and parenteral nutrition. This study aimed to determine the outcomes of TICVAD implantation and use in patients aged ≥85 years. Between January 2010 and August 2016, 117 patients underwent TICVAD implantation and their records were retrospectively reviewed. Participants were divided into 2 groups (plus-85 and sub-85 groups). Fifty-five patients (47.0%) had solid organ cancer alone; 35 patients (29.9%) had cerebrovascular or cranial nerve disease. The average follow-up period was 201 (2-1,620) days. Major complications were identified in 6 (14.6%) plus-85 patients and 11 (14.5%) sub-85 patients (p = 0.9813). Catheter-related infections developed in 3 plus-85 (7.3%) and 4 sub-85 patients (5.3%; p = 0.6549). There were no significant group differences in hematoma, pneumothorax, occlusion, and removal rates. In plus-85 patients examined just before surgery and a month after surgery, increased rates of serum albumin and Onodera's prognostic nutritional index were observed in 48% (14/39) and 41% (12/39), respectively. The use of TICVADs in the plus-85 group resulted in effective outcomes. The results of this retrospective study support the wider use of TICVADs in patients aged ≥85 years. © 2018 S. Karger AG, Basel.

  3. Percutaneous closure of patent ductus arteriosus in children: Immediate and short-term changes in left ventricular systolic and diastolic function

    OpenAIRE

    Gupta, Saurabh Kumar; Krishnamoorthy, KM; Tharakan, Jaganmohan A; Sivasankaran, S; Sanjay, G; Bijulal, S; Anees, T

    2011-01-01

    Objective: To evaluate the effect of percutaneous closure of patent ductus arteriosus (PDA) on left ventricular (LV) systolic and diastolic function in children. Background: Limited studies are available on alteration in LV hemodynamics, especially diastolic function, after PDA closure. Methods: Thirty-two consecutive children with isolated PDA treated by trans-catheter closure were studied. The LV systolic and diastolic function were assessed by two-dimensional (2D) echocardiography ...

  4. Right ventricular bifocal stimulation in the treatment of dilated cardiomyopathy with heart failure

    Directory of Open Access Journals (Sweden)

    José Carlos Pachón Mateos

    1999-12-01

    Full Text Available OBJECTIVE: To describe a new more efficient method of endocardial cardiac stimulation, which produces a narrower QRS without using the coronary sinus or cardiac veins. METHODS: We studied 5 patients with severe dilated cardiomyopathy, chronic atrial fibrillation and AV block, who underwent definitive endocardial pacemaker implantation, with 2 leads, in the RV, one in the apex and the other in the interventricular septum (sub pulmonary, connected, respectively, to ventricular and atrial bicameral pacemaker outputs. Using Doppler echocardiography, we compared, in the same patient, conventional (VVI, high septal ("AAI" and bifocal ("DDT" with AV interval ~ 0 stimulation. RESULTS: The RV bifocal stimulation had the best results with an increase in ejection fraction and cardiac output and reduction in QRS duration, mitral regurgitation and in the left atrium area (p <= 0.01. The conventional method of stimulation showed the worst result. CONCLUSION: These results suggest that, when left ventricular stimulation is not possible, right ventricular bifocal stimulation should be used in patients with severe cardiomyopathy where a pacemaker is indicated.

  5. Implant survival of the most common cemented total hip devices from the Nordic Arthroplasty Register Association database

    DEFF Research Database (Denmark)

    Junnila, Mika; Laaksonen, Inari; Eskelinen, Antti

    2016-01-01

    Background and purpose - According to previous Nordic Arthroplasty Register Association (NARA) data, the 10-year implant survival of cemented total hip arthroplasties (THAs) is 94% in patients aged 65-74 and 96% in patients aged 75 or more. Here we report a brand-level comparison of cemented THA...

  6. Mechanical dispersion and global longitudinal strain by speckle tracking echocardiography: Predictors of appropriate implantable cardioverter defibrillator therapy in hypertrophic cardiomyopathy.

    Science.gov (United States)

    Candan, Ozkan; Gecmen, Cetin; Bayam, Emrah; Guner, Ahmet; Celik, Mehmet; Doğan, Cem

    2017-06-01

    In this study, we investigated whether mechanical dispersion which reflects electrical abnormality and other echocardiographic and clinic parameters predict appropriate ICD shock in patients undergone ICD implantation for hypertrophic cardiomyopathy. Sixty-three patients who received ICD implantation for primary or secondary prevention were included in the study. Patients' clinical, electrocardiographic, 2D classic, and speckle tracking echocardiographic data were collected. Mechanical dispersion was defined as the standard deviation of time to peak negative strain in 18 left ventricular segments. Appropriate ICD therapy was defined as cardioversion or defibrillation due to ventricular tachycardia or fibrillation. Patients were divided into two groups as occurrence or the absence of appropriate ICD therapy. A total of 17 (26.9%) patients were observed to have an appropriate ICD therapy during follow-up periods. In patients who performed appropriate ICD therapy, a larger left atrial volume index, higher sudden cardiac death (SCD)-Risk Score, longer mechanical dispersion, and decreased global longitudinal peak strain (GLPS) were observed. In multivariate logistic regression analysis, including (GLPS, mechanical dispersion, LAVi, and SCD-Risk Score) was used to determine independent predictors of occurrence of appropriate ICD therapy during the follow-up. Mechanical dispersion, GLPS, and SCD-Risk Score were found to be independent predictors of occurrence of appropriate ICD therapy. Mechanical dispersion, GLPS, and SCD-Risk Score were found to be predictive for appropriate ICD therapy in patients receiving ICD implantation. Readily measurable mechanical dispersion and GLPS could be helpful to distinguish patients at high risk who could optimally benefit from ICD therapy. © 2017, Wiley Periodicals, Inc.

  7. Muscular anatomy of the human ventricular folds.

    Science.gov (United States)

    Moon, Jerald; Alipour, Fariborz

    2013-09-01

    Our purpose in this study was to better understand the muscular anatomy of the ventricular folds in order to help improve biomechanical modeling of phonation and to better understand the role of these muscles during phonatory and nonphonatory tasks. Four human larynges were decalcified, sectioned coronally from posterior to anterior by a CryoJane tape transfer system, and stained with Masson's trichrome. The total and relative areas of muscles observed in each section were calculated and used for characterizing the muscle distribution within the ventricular folds. The ventricular folds contained anteriorly coursing thyroarytenoid and ventricularis muscle fibers that were in the lower half of the ventricular fold posteriorly, and some ventricularis muscle was evident in the upper and lateral portions of the fold more anteriorly. Very little muscle tissue was observed in the medial half of the fold, and the anterior half of the ventricular fold was largely devoid of any muscle tissue. All 4 larynges contained muscle bundles that coursed superiorly and medially through the upper half of the fold, toward the lateral margin of the epiglottis. Although variability of expression was evident, a well-defined thyroarytenoid muscle was readily apparent lateral to the arytenoid cartilage in all specimens.

  8. Teores de ácidos graxos trans de alguns alimentos consumidos no Rio de Janeiro Trans fatty acids of some foods consumed in Rio de Janeiro, Brazil

    Directory of Open Access Journals (Sweden)

    Vera Lúcia Chiara

    2003-06-01

    Full Text Available Desconhecem-se os teores de ácidos graxos trans em diversos alimentos. Este estudo analisou os teores de ácidos graxos trans, saturados, monoinsaturados e poliinsaturados em batatas fritas, biscoitos e sorvetes. As batatas fritas foram dos tipos chips e de duas redes de fast food, os sorvetes, de duas marcas comerciais e de duas lojas de fast food, e os biscoitos, de marcas diferentes. As amostras de batatas chips e de biscoitos pertenciam a lotes distintos e foram adquiridas em supermercados da região. Analisaram-se seis amostras por produto, através de cromatografia gasosa. O valor médio dos ácidos trans de batatas fritas de redes de fast food foi de 4,74g/100g, enquanto em batatas chips estes ácidos graxos não foram detectados. Nos sorvetes os valores variaram de 0,041g a 1,41g e em biscoitos, de 2,81g a 5,60g. Biscoitos tipo cream cracker apresentaram teores de ácidos graxos trans mais altos e de insaturados mais baixos. Concluiu-se que alguns produtos apresentaram, em 100g, teores de ácidos graxos trans superiores aos recomendados para ingestão total diária em diversos países.The content of trans fatty acids in most consumed foods in Brazil is unknown. This study assessed trans saturated, monounsaturated and polyunsaturated fatty acids in samples of fried potatoes, cookies and ice cream. The analysis included: potato chips and fried potatoes from two popular fast food restaurants, ice cream of two different trademarks and from two fast food restaurants, and cookies of different trademarks. The samples of potato chips and cookies were acquired in different supermarkets in the city of Rio de Janeiro, and distinct manufacture dates were chosen. Six samples of each product were analyzed through gas chromatography. The average trans fatty acids content in fried potatoes from fast food restaurants was 4.74g/100g; in ice cream the values varied from 0.041g to 1.41g; and in cookies the values varied from 2.81g to 5.60g. No trans fatty

  9. Studies of left ventricular volume estimation from single photon emission computed tomography

    International Nuclear Information System (INIS)

    Hiraki, Yoshio; Shimizu, Mitsuharu; Joja, Ikuo; Aono, Kaname; Yanagi, Hidekiyo; Indo, Haruaki; Seno, Yoshimasa; Teramoto, Shigeru; Nagaya, Isao.

    1988-01-01

    We studied the comparative accuracy of 99m Tc cardiac blood pool Single Photon Emission Computed Tomography (SPECT) for the measurement of left ventricular volume in 20 patients undergoing SPECT and single plane contrast left ventriculography (LVG). Left ventricular volume was calculated based on the total number of voxels in left ventricle. End-diastolic left ventricular volume (EDV) and end-systolic left ventricular volume (ESV) calculated from SPECT were compared with those from LVG. SPECT volume values showed a high degree of correlation with those by LVG (r = 0.923 for EDV, r = 0.903 for ESV). We appreciated the usefulness and accuracy of SPECT in measuring left ventricular volume because of its three-dimensional information. (author)

  10. HEART ELECTRICAL AXIS Α ANGLE VALUES DISTRIBUTION IN PATIENTS, UNDERGOING PERMANENT PACEMAKER IMPLANTATION

    Directory of Open Access Journals (Sweden)

    O. S. Voronenko

    2016-06-01

    Full Text Available 52 patients (24 male and 28 female aged 71 ± 8 years, underwent permanent pacemaker implantation were included in the study. Analysis of heart electrical axis (HEA α angle values distribution was carried out in three dimensions in patience before and after pacemaker (PM implantation. The data processed in Microsoft Excel with calculation of the average and it’s standard deviation. Significance of differences in data before and after PM implantation was assessed using Friedman ANOVA test and Kendall concordance coefficient. It was found, that α angle values distribution in patients with implanted PM is transformed from a unimodal to bimodal on the permanent cardiac pacing background. It’s assumed, that α angle changes resulting due to right ventricular electrode positioning options during PM implantation. Clarification of the nature of this change requires a special study.

  11. Implante valve-in-valve transcateter em posição aórtica: uma mudança de seleção? Transcatheter aortic valve-in-valve implantation: a selection change?

    Directory of Open Access Journals (Sweden)

    Diego Felipe Gaia

    2012-09-01

    Full Text Available INTRODUÇÃO: A reoperação para substituição de biopróteses aórticas com disfunção é procedimento que envolve considerável risco. Em alguns casos, a mortalidade é elevada e pode contraindicar o procedimento. O implante minimamente invasivo "valve-in-valve" transcateter de valva aórtica parece ser uma alternativa, reduzindo morbimortalidade. O objetivo deste estudo foi avaliar esses implantes utilizando a prótese Braile Inovare. MÉTODOS: A prótese Braile Inovare, transcateter, balão expansível foi utilizada em 14 casos. Euroscore médio foi de 42,9%. Todos os pacientes eram portadores de dupla disfunção de bioprótese aórtica. Os procedimentos foram realizados em ambiente cirúrgico híbrido, sob controle ecocardiográfico e fluoroscópico. Por meio de minitoracotomia esquerda, as próteses foram implantadas através do ápice ventricular, sob estimulação ventricular de alta frequência. Foram realizados controles clínicos e ecocardiográficos seriados. O seguimento variou de 1 a 30 meses. RESULTADOS: A correta liberação protética foi possível em todos os casos. Não ocorreu conversão. Não houve mortalidade operatória. A mortalidade em 30 dias foi de 14,3% (dois casos. A fração de ejeção apresentou aumento significativo após o 7º pós-operatório e o gradiente aórtico apresentou redução significativa. A insuficiência aórtica residual não esteve presente. Não ocorreu complicação vascular periférica ou bloqueio atrioventricular total. CONCLUSÕES: O implante "valve-in-valve" de valva aórtica transcateter em biopróteses com disfunção é um procedimento seguro e com morbimortalidade baixa. Essa possibilidade poderá alterar a indicação de seleção de prótese no procedimento inicial, favorecendo próteses biológicas.OBJECTIVE: Aortic valve replacement for bioprosthesis dysfunction is a procedure involving considerable risk. In some cases, mortality is high and may contraindicate the procedure

  12. Implant of permanent pacemaker during acute coronary syndrome: Mortality and associated factors in the ARIAM registry.

    Science.gov (United States)

    Pola-Gallego-de-Guzmán, María Dolores; Ruiz-Bailén, Manuel; Martínez-Arcos, Maria-Angeles; Gómez-Blizniak, Artur; Castillo Rivera, Ana-Maria; Molinos, Jesus Cobo

    2018-04-01

    Patients with acute coronary syndrome complicated with high degree atrioventricular block still have a high mortality. A low percentage of these patients need a permanent pacemaker (PPM) but mortality and associated factors with the PPM implant in acute coronary syndrome patients are not known. We assess whether PPM implant is an independent variable in the mortality of acute coronary syndrome patients. Also, we explored the variables that remain independently associated with PPM implantation. This was an observational study on the Spanish ARIAM register. The inclusion period was from January 2001 to December 2011. This registry included all Andalusian acute coronary syndrome patients. Follow-up for global mortality was until November 2013. We selected 27,608 cases. In 62 patients a PPM was implanted (0.024%). The mean age in PPM patients was 70.71±11.214 years versus 64.46±12.985 years in patients with no PPM. PPM implant was associated independently with age (odds ratio (OR) 1.031, 95% confidence interval (CI) 1.007-1.055), with left ventricular branch block (OR 6.622, 95% CI 2.439-18.181), with any arrhythmia at intensive care unit admission (OR 2.754, 95% CI 1.506-5.025) and with heart failure (OR 3.344, 95% CI 1.78-8.333). PPM implant was independently associated with mortality (OR 11.436, 95% CI 1.576-83.009). In propensity score analysis PPM implant was still associated with mortality (OR 5.79, 95% CI 3.27-25.63). PPM implant is associated with mortality in the acute coronary syndrome population in the ARIAM registry. Advanced age, heart failure, arrhythmias and left ventricular branch block at intensive care unit admission were found associated factors with PPM implant in acute coronary syndrome patient.

  13. Association of HeartMate II left ventricular assist device flow estimate with thermodilution cardiac output.

    Science.gov (United States)

    Hasin, Tal; Huebner, Marianne; Li, Zhuo; Brown, Daniel; Stulak, John M; Boilson, Barry A; Joyce, Lyle; Pereira, Naveen L; Kushwaha, Sudhir S; Park, Soon J

    2014-01-01

    Cardiac output (CO) assessment is important in treating patients with heart failure. Durable left ventricular assist devices (LVADs) provide essentially all CO. In currently used LVADs, estimated device flow is generated by a computerized algorithm. However, LVAD flow estimate may be inaccurate in tracking true CO. We correlated LVAD (HeartMate II) flow with thermodilution CO during postoperative care (day 2-10 after implant) in 81 patients (5,616 paired measurements). Left ventricular assist device flow and CO correlated with a low correlation coefficient (r = 0.42). Left ventricular assist device readings were lower than CO measurements by approximately 0.36 L/min, trending for larger difference with higher values. Left ventricular assist device flow measurements showed less temporal variability compared with CO. Grouping for simultaneous measured blood pressure (BP device flow generally trends with measured CO, but large variability exists, hence flow measures should not be assumed to equal with CO. Clinicians should take into account variables such as high CO, BP, and opening of the aortic valve when interpreting LVAD flow readout. Direct flow sensors incorporated in the LVAD system may allow for better estimation.

  14. Perfil de ácidos graxos trans de óleo e gordura hidrogenada de soja no processo de fritura Fatty acids trans profile of oil and hidrogenated soy fat in frying process

    Directory of Open Access Journals (Sweden)

    Elaine Abrão Assef Sanibal

    2004-03-01

    Full Text Available O objetivo desse estudo foi avaliar as alterações dos ácidos graxos e a formação de isômeros trans, durante o aquecimento de óleo de soja (OS e gordura parcialmente hidrogenada de soja (GPHS no processo de fritura de batata por 100 horas com reposição lipídica. O perfil de ácidos graxos foi avaliado através de cromatografia gasosa em coluna capilar de 100m. Os ácidos graxos monoinsaturados trans foram os predominantes entre os isômeros trans. A partir de 10 horas de fritura, o OS formou 2,1% de isômeros mono trans e ao final de 50 horas este valor passou a 14,3% contra uma diminuição do total de ácidos graxos poliinsaturados, que passou de 59,9% antes do processamento para 32,6% após 50h de fritura. Entretanto, a GPHS apresentou 20,2% de ácidos graxos mono trans antes de ser submetida à fritura e após 50 horas apresentou uma concentração de 28%. Houve também, uma diminuição do total de ácidos graxos essenciais séries ômega6 e ômega3, de 12,8% para 7,3% no mesmo período. Os resultados obtidos revelaram que isômeros trans são formados no óleo e na gordura durante o processo de fritura, sendo que a formação de isômeros trans, ocorreu em menor proporção na GPHS, confirmando a sua maior estabilidade em relação ao OS. Estes resultados indicam a importância de se identificar os ácidos graxos trans nos óleos e gorduras ulizadas em processos de fritura.The objective of this study, was to examine the alterations of the fatty acids profile and the formation of trans fatty acids isomers during heating of soy oil (SO and partially hydrogenated soy fat (PHSF in the process of french frying. The fatty acids profile was examined by gas chromatography with a 100m capillary column. The fatty acids trans monounsaturated were the predominant among trans isomers. The isomers trans monounsaturated corresponded to 2.1% of the total, after 10 hours of frying, and 14.3% after 50h - frying. Poliunsaturated fatty acids

  15. Detection of premature ventricular contractions on a ventricular electrocardiogram for patients with left ventricular assist devices.

    Science.gov (United States)

    Park, Sung Min; Lee, Jin Hong; Choi, Seong Wook

    2014-12-01

    The ventricular electrocardiogram (v-ECG) was developed for long-term monitoring of heartbeats in patients with a left ventricular assist device (LVAD) and does not normally have the functionality necessary to detect additional heart irregularities that can progress to critical arrhythmias. Although the v-ECG has the benefits of physiological optimization and counterpulsation control, when abnormal heartbeats occur, the v-ECG does not show the distinct abnormal waveform that enables easy detection of an abnormal heartbeat among normal heartbeats on the conventional ECG. In this study, the v-ECGs of normal and abnormal heartbeats are compared with each other with respect to peak-to-peak voltage, area, and maximal slopes, and a new method to detect abnormal heartbeats is suggested. In a series of animal experiments with three porcine models (Yorkshire pigs weighing 30-40 kg), a v-ECG and conventional ECG were taken simultaneously during LVAD perfusion. Clinical experts found 104 abnormal heartbeats from the saved conventional ECG data and confirmed that the other 3159 heartbeats were normal. Almost all of the abnormal heartbeats were premature ventricular contractions (PVCs), and there was short-term tachycardia for 3 s. A personal computer was used to automatically detect abnormal heartbeats with the v-ECG according to the new method, and its results were compared with the clinicians' results. The new method found abnormal heartbeats with 90% accuracy, and less than 15% of the total PVCs were missed. Copyright © 2014 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  16. Study of reactions of isotopic exchange of trans-zeatin with tritium

    International Nuclear Information System (INIS)

    Sidorov, G.V.; Myasoedov, N.F.

    2006-01-01

    Reactions of isotopic exchange of trans-zeatin with high-radioactive tritium water, with gaseous tritium in solution and solid-phase catalytic hydrogenation are studied to prepare trans-zeatin and dihydrozeatin labelled with tritium. It is shown that reaction of isotopic exchange of trans-zeatin with gaseous tritium both in solutions and without solvents at 160 Deg C and above leads to practically total hydrogenation of initial compound with formation of dihydrozeatin labelled with tritium. Isotopic exchange with tritium water permits to prepare zeatin labelled with tritium with 67 % yield and specific radioactivity 0.68 PBq/mol. It is determined that in the case of solid-phase isotopic exchange within 150-155 Deg C temperature interval both dihydrozeatin and trans-zeatin labelled with tritium are formed [ru

  17. Remote Left Ventricular Hemodynamic Monitoring Using a Novel Intracardiac Sensor.

    Science.gov (United States)

    Mondritzki, Thomas; Boehme, Philip; White, Jason; Park, Jin Woo; Hoffmann, Jessica; Vogel, Julia; Kolkhof, Peter; Walsh, Stuart; Sandner, Peter; Bischoff, Erwin; Dinh, Wilfried; Hüser, Jörg; Truebel, Hubert

    2018-05-01

    Heart failure (HF) remains the most common reason for hospital admission in patients aged >65 years. Despite modern drug therapy, mortality and readmission rates for patients hospitalized with HF remain high. This necessitates further research to identify early patients at risk for readmission to limit hospitalization by timely adjustment of medical therapy. Implantable devices can monitor left ventricular (LV) hemodynamics and remotely and continuously detect the early signs of decompensation to trigger interventions and reduce the risk of hospitalization for HF. Here, we report the first preclinical study validating a new batteryless and easy to implant LV-microelectromechanical system to assess LV performance. A miniaturized implantable wireless pressure sensor was adapted for implantation in the LV apex. The LV-microelectromechanical system sensor was tested in a canine model of HF. The wireless pressure sensor measurements were compared with invasive left heart catheter-derived measurements at several time points. During different pharmacological challenge studies with dobutamine or vasopressin, the device was equally sensitive compared with invasive standard procedures. No adverse events or any observable reaction related to the implantation and application of the device for a period of 35 days was observed. Our miniaturized wireless pressure sensor placed in the LV (LV-microelectromechanical system) has the potential to become a new telemetric tool to earlier identify patients at risk for HF decompensation and to guide the treatment of patients with HF. © 2018 American Heart Association, Inc.

  18. Does the number of implants have any relation with peri-implant disease?

    Directory of Open Access Journals (Sweden)

    Bernardo Born PASSONI

    2014-10-01

    Full Text Available Objective: The aim of this study was to evaluate the relationship between the number of pillar implants of implant-supported fixed prostheses and the prevalence of periimplant disease. Material and Methods: Clinical and radiographic data were obtained for the evaluation. The sample consisted of 32 patients with implant-supported fixed prostheses in function for at least one year. A total of 161 implants were evaluated. Two groups were formed according to the number of implants: G1 ≤5 implants and G2 >5 implants. Data collection included modified plaque index (MPi, bleeding on probing (BOP, probing depth (PD, width of keratinized mucosa (KM and radiographic bone loss (BL. Clinical and radiographic data were grouped for each implant in order to conduct the diagnosis of mucositis or peri-implantitis. Results: Clinical parameters were compared between groups using Student’s t test for numeric variables (KM, PD and BL and Mann-Whitney test for categorical variables (MPi and BOP. KM and BL showed statistically significant differences between both groups (p<0.001. Implants from G1 – 19 (20.43% – compared with G2 – 26 (38.24% – showed statistically significant differences regarding the prevalence of peri-implantitis (p=0.0210. Conclusion: It seems that more than 5 implants in total fixed rehabilitations increase bone loss and consequently the prevalence of implants with periimplantitis. Notwithstanding, the number of implants does not have any influence on the prevalence of mucositis.

  19. Systolic left ventricular function according to left ventricular concentricity and dilatation in hypertensive patients

    DEFF Research Database (Denmark)

    Bang, Casper; Gerdts, Eva; Aurigemma, Gerard P

    2013-01-01

    Left ventricular hypertrophy [LVH, high left ventricular mass (LVM)] is traditionally classified as concentric or eccentric based on left ventricular relative wall thickness. We evaluated left ventricular systolic function in a new four-group LVH classification based on left ventricular dilatation...... [high left ventricular end-diastolic volume (EDV) index and concentricity (LVM/EDV)] in hypertensive patients....

  20. Left ventricular function in patients with ventricular arrhythmias and aortic valve disease

    International Nuclear Information System (INIS)

    Santinga, J.T.; Kirsh, M.M.; Brady, T.J.; Thrall, J.; Pitt, B.

    1983-01-01

    Forty patients having aortic valve replacement were evaluated preoperatively for ventricular arrhythmia and left ventricular ejection fraction. Arrhythmias were classified as complex or simple using the Lown criteria on the 24-hour ambulatory electrocardiogram; ejection fractions were determined by radionuclide gated blood pool analysis and contrast angiography. The ejection fractions determined by radionuclide angiography were 59.1 +/- 13.1% for 26 patients with simple or no ventricular arrhythmias, and 43.9 +/- 20.3% for 14 patients with complex ventricular arrhythmias (p less than 0.01). Ejection fractions determined by angiography, available for 31 patients, were also lower in patients with complex ventricular arrhythmias (61.1 +/- 16.3% versus 51.4 +/- 13.4%; p less than 0.05). Seven of 9 patients showing conduction abnormalities on the electrocardiogram had complex ventricular arrhythmias. Eight of 20 patients with aortic stenosis had complex ventricular arrhythmias, while 2 of 13 patients with aortic insufficiency had such arrhythmias. It is concluded that decreased left ventricular ejection fraction, intraventricular conduction abnormalities, and aortic stenosis are associated with an increased frequency of complex ventricular arrhythmias in patients with aortic valve disease

  1. Rest and exercise ventricular function in adults with congenital ventricular septal defects

    International Nuclear Information System (INIS)

    Jablonsky, G.; Hilton, J.D.; Liu, P.P.; Morch, J.E.; Druck, M.N.; Bar-Shlomo, B.Z.; McLaughlin, P.R.

    1983-01-01

    Rest and exercise right and left ventricular function were compared using equilibrium gated radionuclide angiography in 19 normal sedentary control subjects and 34 patients with hemodynamically documented congenital ventricular septal defect (VSD). Gated radionuclide angiography was performed at rest and during each level of graded supine bicycle exercise to fatigue. Heart rate, blood pressure, maximal work load achieved, and right and left ventricular ejection fractions were assessed. The control subjects demonstrated an increase in both the left and right ventricular ejection fractions with exercise. All study groups failed to demonstrate an increase in ejection fraction in either ventricle with exercise. Furthermore, resting left ventricular ejection fraction in Groups 2 and 3 was lower than that in the control subjects and resting right ventricular ejection fraction was lower in Group 3 versus control subjects. Thus left and right ventricular function on exercise were abnormal in patients with residual VSD as compared with control subjects; rest and exercise left ventricular ejection fractions remained abnormal despite surgical closure of VSD in the remote past; resting left and right ventricular function was abnormal in patients with Eisenmenger's complex; lifelong volume overload may be detrimental to myocardial function

  2. Left ventricular performance during psychological stress

    International Nuclear Information System (INIS)

    Young, D.Z.; Massachusetts General Hospital, Boston; Dimsdale, J.E.; Moore, R.H.; Barlai-Kovach, M.; Newell, J.B.; McKusick, K.A.; Boucher, C.A.; Fifer, M.A.; Strauss, H.W.

    1989-01-01

    Left ventricular ejection fraction, systolic blood pressure and plasma norepinephrine were measured in six normotensive and six mildly hypertensive subjects during rest and psychological stress. Compared with rest, 8 of the 12 subjects developed significant changes in ejection fraction (increase in 6, decrease in 2); 10 of 12 subjects developed significant elevations of plasma norepinephrine; and all developed significant increases in systolic blood pressure. When the stress effects were examined for the total group, as opposed to within subjects, there were significant increases in plasma norepinephrine and systolic blood pressure but, interestingly, mean ejection fraction and stroke volume remained unchanged, implying stress led to increased left ventricular contractility. (orig.)

  3. Effects of SMILE and Trans-PRK on corneal higher order aberrations after myopic correction

    Directory of Open Access Journals (Sweden)

    Jiao Zhao

    2018-02-01

    Full Text Available AIM:To observe the effects of small incision lenticule extraction(SMILEand trans-epithelial photorefractive keratectomy(Trans-PRKon corneal horizontal coma, vertical coma, and spherical aberration and total higher order aberrations after refractive correction for myopia. METHODS: This was a prospective non-randomized cohort study. The cohort included 40 patients(80 eyeswith myopia, who received refraction correction surgery from December 2016 to February 2017 in Leshan Ophthalmic Center. Twenty patients(40 eyesreceived SMILE surgery and the other 20 patients(40 eyesreceived Trans-PRK surgery. Corneal aberrations were determined by a high-resolution Pentacam Scheimpflug camera before the surgery and at 1 and 3mo after the operation. Statistical analyses were performed using analysis of variance of repeated measures. RESULTS: At 1 and 3mo post-operation, the uncorrected visual acuity in both groups was better than or equal to the preoperative best corrected visual acuity. The preoperative corneal aberrations showed no significant difference between the two groups(P>0.05. Significantly higher aberration was found after the surgery in both groups(PP>0.05. Post-operation, horizontal and vertical coma had no significant difference between the two groups(P>0.05, while SMILE group showed lower spherical aberration and lower total higher order aberration than Trans-PRK group(PCONCLUSION: Both SMILE and Trans-PRK increase corneal aberration and their effects on horizontal and vertical coma are similar. However, SMILE has a minor influence on spherical aberration and total high order aberration than Trans-PRK.

  4. Right ventricular dysfunction following continuous flow left ventriccular assist device placement in 51 patients: predicators and outcomes

    Directory of Open Access Journals (Sweden)

    Neragi-Miandoab Siyamek

    2012-06-01

    Full Text Available Abstract Background Right ventricular (RV dysfunction following implantation of a left ventricular assist device (LVAD is a serious condition and is associated with increased mortality. Methods The aim of the study is to investigate the significance of pre-existing RV dysfunction, tricuspid valve (TV insufficiency, and the severity of septal deviation following LVAD implantation on RV dysfunction, as well as the outcome and short-term complications in 51 patients from June 2006 to August 2010. Student t test was used to compare the data and estimate the p value. Results Mean age was 55.1 ± 13, with a male to female ratio of 3.25. The 30-day mortality was 13.7% (7/51 patients, and the overall mortality was 23.5% (12/51 patients. Meanwhile, 21 patients (21/51; 41.2% have undergone orthotopic heart transplantation. The mean time of support was 314.5±235 days with a median of 240 days at the time of closing this study. Echocardiographic evaluation of RV function pre- and post-implantation of an LVAD demonstrated septal deviation towards the left ventricle in immediate postoperative phase, which correlated with acute RV dysfunction (p = 0.002. Preoperative RV dysfunction was a significant predictor of postoperative right heart dysfunction following implantation of an LVAD (p = 0.001. Conclusion Preoperative RV dysfunction is a predictor of RV failure in LVAD patients. The adjustment of septal deviation through gradual increase of the LVAD flow can prevent the acute RV dysfunction following LVAD placement.

  5. Effect of dual-chamber minimal ventricular pacing on paroxysmal atrial fibrillation incidence in myotonic dystrophy type 1 patients: A prospective, randomized, single-blind, crossover study.

    Science.gov (United States)

    Russo, Vincenzo; Papa, Andrea Antonio; Rago, Anna; Ciardiello, Carmine; Nigro, Gerardo

    2018-03-08

    Atrial fibrillation (AF) is a common finding in the myotonic dystrophy type 1 (DM1) population. Pacemakers (PMs) may facilitate the diagnosis and management of frequent subclinical asymptomatic AF episodes. The purpose of this study was to evaluate the effect of minimal ventricular pacing on paroxysmal AF incidence in DM1 patients during a 24-month follow-up period. We enrolled 70 DM1 patients (age 43.4 ± 13.8 years; 39 women) who underwent dual-chamber PM implantation. Patients were randomized to minimizing ventricular pacing features (ON) or not (OFF). Patients crossed over to the opposite pacing programming 12 months later. We counted the number of DM1 patients with at least 1 episode of AF, the AF total duration, and the burden recorded by PM diagnostics during the MVP ON and OFF phases. Twenty-five DM1 patients (41.7%) showed at least 1 AF episode. Seven patients (11.7%) demonstrated AF episodes during MVP ON phase and 25 patients (41.7%) during MVP OFF phase (P MVP ON or OFF phase, 3 patients had AF episodes only during MVP ON phase, 21 patients had AF episodes only during MVP OFF phase, and 4 patients had AF episodes during MVP ON and OFF phases. Activation of the MVP algorithm was associated with a 44% reduction in relative risk of developing AF. Furthermore, during the MVP ON phases, the study population showed a shorter total AF duration and a lower AF burden. MVP is an efficacy strategy for reducing the risk of AF in DM1 patients who have undergone PM implantation. Copyright © 2018 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  6. Trans fatty acid intake among the population of the city of São Paulo, Brazil Consumo de ácidos grasos trans en la población de la ciudad de Sao Paulo, Sureste de Brasil Consumo de ácidos graxos trans na população da cidade de São Paulo, Brasil

    Directory of Open Access Journals (Sweden)

    Michelle Alessandra de Castro

    2009-12-01

    Full Text Available OBJECTIVE: To analyze the monounsaturated and polyunsaturated trans fatty acid intake among the general population. METHODS: A cross-sectional study was conducted in São Paulo, Southeastern Brazil, in 2003, on a representative sample of 2,298 male and female subjects, including 803 adolescents (12 to 19 years, 713 adults (20 to 59 years and 782 elderly people (60 years or over. Food intake was measured using 24-hour recall. Mean trans fatty acid intake was described according to gender and age group. RESULTS: The mean trans fatty acid intake was 5.0 g/day (SE = 0.1, accounting for 2.4% (SE = 0.1 of total energy and 6.8% (SE = 0.1 of total lipids. The adolescents had the highest mean intake levels (7.4 g/day; 2.9% of energy while the adults and the elderly had similar intake (2.2% of energy for both; 6.4% of lipids and 6.5% of lipids, respectively. The mean trans fatty acid intake among adult and elderly women (approximately 2.5% of energy and 7.0% of lipids was higher than among men in the same age group. The food item with the highest contribution towards trans fatty acids was margarine, accounting for more than 30% of total intake, followed by filled cookies among adolescents and meat among adults and the elderly. CONCLUSIONS: The trans fatty acid intake is above the level recommended by the World Health Organization. Replacement of the trans fatty acids in manufactured food items may be an effective measure for reducing trans fatty acid intake in Brazil.OBJETIVO: Analizar el consumo de ácidos grasos moninsaturados y polinsaturados de configuración trans en la población general. MÉTODOS: Estudio transversal realizado en Sao Paulo, Sureste de Brasil, 2003, con muestra representativa de 2.298 individuos, siendo 803 adolescentes (12 a 19 años, 713 adultos (20 a 59 años y 782 ancianos (60 años o más, de ambos sexos. El consumo alimentario fue medido por medio del recordatorio alimentario de 24 horas. Los valores promedios de ingestión de

  7. Incidence and impact of prosthesis-patient mismatch after transcatheter aortic valve implantation.

    Science.gov (United States)

    Bleiziffer, Sabine; Hettich, Ina; Hutter, Andrea; Wagner, Anke; Deutsch, Marcus-André; Piazza, Nicolo; Lange, Rüdiger

    2013-05-01

    The study aim was to investigate the incidence of patient-prosthesis mismatch (PPM) with new catheter valves, and its influence on the patients' clinical state. At present, few echocardiographic data are available on the incidence and impact of PPM with the CoreValve and Sapien prostheses for transcatheter aortic valve implantation (TAVI). The reliability of effective orifice area (EOA) measurements was assured by awaiting an interval of six months after TAVI. Of 256 survivors after TAVI, 149 complete echocardiographic data sets were available for the assessment of the indexed EOA (iEOA). In total, 106 CoreValve prostheses and 43 Sapien prostheses were implanted in this high-risk cohort (mean age 81 +/- 6 years, mean logistic EuroSCORE 20 +/- 13%). The overall incidence of PPM (iEOA body surface area were more likely to develop PPM (p = 0.001), while the prosthesis type, native annulus diameter, preoperative EOA, gender and prosthesis size had no influence. The mean aortic gradient was significantly higher in patients with PPM. A reduction in the left ventricular end-diastolic diameter was seen in all patients, without significant differences between groups. There were no differences in postoperative NYHA class or self-assessed health state between patients with or without PPM. PPM was common after TAVI in the presented cohort, presumably because the native calcium masses narrow the outflow area available for blood flow. As expected for low gradients, there was no impairment of left ventricular dimension regression or clinical state of the patients, even if severe PPM was present. Based on the presented data, it is assumed that PPM might be less relevant in TAVI patients.

  8. Predictors of clinical outcome in total hip and knee replacement : a methodological appraisal of implants and patient factors

    NARCIS (Netherlands)

    Keurentjes, Johan Christiaan

    2014-01-01

    In this thesis, we studied both implants and patient and surgeon factors as predictors of clinical outcome after total hip and knee replacement. Additionally, we studied a number of methodological aspects of orthopaedic research, such as competing risks in estimating the probability of revision

  9. The Subcutaneous Implantable Cardioverter-Defibrillator: A Practical Review and Real-World Use and Application

    Directory of Open Access Journals (Sweden)

    Mark E. Panna Jr, MD, FACC, FHRS

    2016-02-01

    Full Text Available The subcutaneous implantable cardioverter-defibrillator (ICD is a novel technology using a subcutaneous (extrathoracic system for treatment of potential lethal ventricular arrhythmias. It avoids many of the risks of transvenous ICD implantation. It may be considered in patients having an ICD indication who do not have a pacing and/or cardiac resynchronization therapy indication, and who are unlikely to benefit from antitachycardia pacing therapy. We review patient selection, system components, the implantation technique, and screening considerations for subcutaneous ICD implantation. Its uses in specific patient populations, including children, patients with congenital heart disease, hypertrophic cardiomyopathy, or end-stage renal disease, and patients with preexisting pacemakers, are highlighted. Areas of future investigation are reviewed, including potential use with leadless pacing and magnetic resonance imaging.

  10. Arrhythmogenic Right Ventricular Cardiomyopathy in an Endurance Athlete Presenting with Ventricular Tachycardia and Normal Right Ventricular Function.

    Science.gov (United States)

    Hedley, Jeffrey S; Al Mheid, Ibhar; Alikhani, Zoubin; Pernetz, Maria A; Kim, Jonathan H

    2017-08-01

    Arrhythmogenic right ventricular cardiomyopathy, a genetically inherited disease that results in fibrofatty replacement of normal cardiac myocytes, has been associated with sudden cardiac death in athletes. Long-term participation in endurance exercise hastens the development of both the arrhythmic and structural arrhythmogenic right ventricular cardiomyopathy phenotypes. We describe the unusual case of a 34-year-old, symptomatic, female endurance athlete who had arrhythmogenic right ventricular cardiomyopathy in the presence of a structurally normal right ventricle. Clinicians should be aware of this infrequent presentation when evaluating athletic patients who have ventricular arrhythmias and normal findings on cardiac imaging studies.

  11. Post procedural complications of cardiac implants done in a resource limited setting under 'C' arm: A single centre experience.

    Science.gov (United States)

    Jayachandra, A; Aggarwal, Vivek; Kumar, Sandeep; Nagesh, I V

    2018-04-01

    Cardiology interventions in peripheral hospitals is a challenging task where cardiologist have to fight against time and limited resources. Most of the sudden cardiac deaths occur due to arrhythmia and heart blocks/sinus node dysfunction. Our study is a single peripheral center experience of cardiac devices implantation using a 'C' Arm. The aim of this study was to post procedural complications of cardiac implants done in aresource limited setting under 'C' arm. This study is done at a peripheral cardiology center with no cardiac catheterization laboratory (CCL) facilities. Consecutive patients reporting to cardiology center, between Jan 2015 and Oct 2016, with a definite indication for cardiac device implant were included in the study. All the procedure of implantation was done in the operation theatre under 'C' arm under local anesthesia with continuous cardiac monitoring and critical care back up. Total 58 device implantations were done from Jan 2015 to Oct 2016. The mean age of the patients was 67.15 ± 10.85 years. Males constituted almost two third (68.9%) of patients. The commonest indication for device implantation was sinus node dysfunction in 60.34% followed by complete heart block in 25.86% and ventricular tachycardia in 12.06%. No post procedure infection was observed in our study. Device implantation constitute a major group of life saving interventions in cardiology practice. Our study has emphasised that when appropriate aseptic measures are taken during device implantation at peripheral centres, the complications rate are comparable to interventions done at advance cardiac centres.

  12. Modified cementless total coxofemoral prosthesis: development, implantation and clinical evaluation

    Directory of Open Access Journals (Sweden)

    S.A. Arias

    2013-12-01

    Full Text Available The aim of this study was to modify canine coxofemoral prostheses and the clinical evaluation of the implantation. Fifteen canine hips and femora of cadavers were used in order to study the surface points of modification in prostheses and develop a perforation guide. Femoral stems and acetabular components were perforated and coated with biphasic calcium phosphate layer. Twelve young adult male mongrel dogs were implanted with coxofemoral prostheses. Six were operated upon and implanted with cemented canine modular hip prostheses, establishing the control group. The remaining six were implanted with a novel design of cementless porous tricalcic phosphate-hydroxyapatite coated hip prostheses. Clinical and orthopedic performance, complications, and thigh muscular hypotrophy were assessed up to the 120th post-operatory day. After 120 days, animals with cementless prostheses had similar clinical and orthopedic performance compared to the cemented group despite the increased pain thigh hypotrophy. Animals that underwent cementless hip prosthesis evidenced more pain, compared to animals with cemented hip prosthesis that required longer recuperation time. No luxations, two fractures and two isquiatic neurapraxies were identified in the course of the study. Using both the cemented and the bioactive coated cementless model were suitable to dogs, showing clinical satisfactory results. Osseointegration and biological fixation were observed in the animals with the modified cementless hip prosthesis.

  13. Why are mini-implants lost: the value of the implantation technique!

    Science.gov (United States)

    Romano, Fabio Lourenço; Consolaro, Alberto

    2015-01-01

    The use of mini-implants have made a major contribution to orthodontic treatment. Demand has aroused scientific curiosity about implant placement procedures and techniques. However, the reasons for instability have not yet been made totally clear. The aim of this article is to establish a relationship between implant placement technique and mini-implant success rates by means of examining the following hypotheses: 1) Sites of poor alveolar bone and little space between roots lead to inadequate implant placement; 2) Different sites require mini-implants of different sizes! Implant size should respect alveolar bone diameter; 3) Properly determining mini-implant placement site provides ease for implant placement and contributes to stability; 4) The more precise the lancing procedures, the better the implant placement technique; 5) Self-drilling does not mean higher pressures; 6) Knowing where implant placement should end decreases the risk of complications and mini-implant loss.

  14. Why are mini-implants lost: The value of the implantation technique!

    Directory of Open Access Journals (Sweden)

    Fabio Lourenço Romano

    2015-02-01

    Full Text Available The use of mini-implants have made a major contribution to orthodontic treatment. Demand has aroused scientific curiosity about implant placement procedures and techniques. However, the reasons for instability have not yet been made totally clear. The aim of this article is to establish a relationship between implant placement technique and mini-implant success rates by means of examining the following hypotheses: 1 Sites of poor alveolar bone and little space between roots lead to inadequate implant placement; 2 Different sites require mini-implants of different sizes! Implant size should respect alveolar bone diameter; 3 Properly determining mini-implant placement site provides ease for implant placement and contributes to stability; 4 The more precise the lancing procedures, the better the implant placement technique; 5 Self-drilling does not mean higher pressures; 6 Knowing where implant placement should end decreases the risk of complications and mini-implant loss.

  15. Comparison of clinical benefits and outcome in patients with programmable and nonprogrammable implantable cardioverter defibrillators.

    Science.gov (United States)

    Mehta, D; Saksena, S; Krol, R B; Makhija, V

    1992-09-01

    Technological advances in implantable cardioverter defibrillators (ICDs) have provided a variety of programmable parameters and antitachycardia therapies whose utility and impact on clinical outcome is presently unknown. ICDs have capabilities for cardioversion defibrillation alone (first generation ICDs), or in conjunction with demand ventricular pacing (second generation ICDs), or with demand pacing and antitachycardia pacing (third generation ICDs). We examined the pattern of antitachycardia therapy use and long-term survival in 110 patients with sustained ventricular tachycardia (VT) or ventricular fibrillation (VF). Group I included 62 patients with nonprogrammable first generation ICDs that delivered committed shock therapy after ventricular tachyarrhythmia detection based on electrogram rate and/or morphology was satisfied. Group II included 48 patients with multiprogrammable ICDs (including second and third generation ICDs) that had programmable tachyarrhythmia detection based on rate and tachycardia confirmation prior to delivery of electrical treatment with either programmable shocks and/or, as in the third generation ICDs, antitachycardia pacing. Incidence and patterns of antitachycardia therapy use and long-term survival were compared in the two groups. The incidence of appropriate shocks in patients who completed 1 year of follow-up was significantly greater in group I (30 of 43 patients = 70% vs 11 of 26 patients = 42%; P less than 0.05). In the total follow-up period, a significantly larger proportion of group I patients as compared to group II patients used the shock therapies (46 of 62 patients = 74% vs 25 of 48 patients = 52%; P less than 0.01), with the majority doing so within the first year of implantation (96% and 92%, respectively). Although the frequency of antitachycardia therapy activation was similar, the number of shocks delivered per patient was lower in group II, particularly in the initial 3 months of follow-up (P = 0.06). No clinical

  16. Implant survival after total elbow arthroplasty

    DEFF Research Database (Denmark)

    Plaschke, Hans Christian; Thillemann, Theis M; Brorson, Stig

    2014-01-01

    in 234 patients at a mean follow-up of 8.7 years (range, 0-27 years). The overall 5-year survival was 90% (95% confidence interval [CI], 88%-94%), and 10-year survival was 81% (95% CI, 76%-86%). TEAs performed with the unlinked design had a relative risk of revision of 1.9 (95% CI, 1.1-3.2) compared...... was to evaluate implant survival and risk factors for revision of TEAs inserted in patients in the eastern part of Denmark in the period from 1980 until 2008. MATERIAL AND METHODS: The Danish National Patient Register provided personal identification numbers for patients who underwent TEA procedures from 1980...

  17. Trans-Cultural, Trans-Language Practices: Potentialities for Rethinking Doctoral Education Pedagogies

    Directory of Open Access Journals (Sweden)

    Sarojni Choy

    2017-01-01

    Full Text Available Over the last decade, there has been a rapid increase in doctoral enrolments of Asian international students in Australian universities. While policies have been developed to meet the needs of these students, there seems to be some confusion around the terms internationalisation, globalisation, bi-cultural, inter-cultural, multi-cultural, and trans-cultural within these policies. In this paper, we define these terms and advocate for a policy position which orients to a futurist definition of culture. We then review the work of Michael Singh and his research team at Western Sydney University who have responded to this rapid increase in Asian international student doctoral enrolments in Australian universities by developing pedagogic principles around notions of trans-language and trans-cultural practices. In the final section of the paper, we then draw on our own experiences of doctoral supervision in Australian universities to reflect on our positioning within the pedagogic principles around trans-language and trans-cultural practices.

  18. Dexmedetomidine could enhance surgical satisfaction in Trans-sphenoidal resection of pituitary adenoma.

    Science.gov (United States)

    Salimi, Alireza; Sharifi, Guive; Bahrani, Houshang; Mohajerani, Seyed A; Jafari, Alireza; Safari, Farhad; Jalessi, Maryam; Mirkheshti, Alireza; Mottaghi, Kamran

    2017-02-01

    Excessive bleeding is an unwanted complication of trans-sphenoidal resection of pituitary adenoma due to increases in intracranial pressure (ICP) and hemodynamic instability. Dexmedetomidine (Dex) anα2-agonists is the drug of choice in intensive care units (ICU) and cardiac surgeries to control abrupt changes in hemodynamic. Severe cardiovascular responses occur during trans-sphenoidal resection (TSR) of the pituitary adenoma despite adequate depth of anesthesia. The aim of this paper was to determine the effect of Dexmedetomidine on bleeding as primary outcome, and surgeon's satisfaction and hemodynamic stability as secondary outcomes in patients undergoing trans-sphenoidal resection of pituitary adenoma. Total numbers of 60 patients between 18-65 years old and candidate for elective trans-sphenoidal resection of pituitary adenoma were randomLy allocated to two groups; Dexmedetomidine infusion (0.6µg/kg/hour) or normal saline infusion. Mean arterial pressure (MAP), heart rate (HR), dose of hypnotics and narcotics during surgery, bleeding, and surgeon's satisfaction were recorded. Propofol maintenance dose (µg/kg/min) and total Fentanyl use (µg) were significantly lower in Dex group compare to control group (P=0.01 and 0.003, respectively). Total bleeding amount during operation in Dex group was significantly lower than control group (P=0.012). Surgeon's satisfaction was significantly higher in Dex group at the end of surgery. MAP and heart rate throughout surgery were significantly lower in Dex group compare to control group (P=0.001). Dexmedetomidine infusion (0.6µg/kg/hour) could reduce bleeding and provide surgeon's satisfaction during trans-sphenoidal resection of pituitary adenoma.

  19. Twenty-Seven Years Experience With Transvenous Pacemaker Implantation in Children Weighing <10 kg.

    Science.gov (United States)

    Konta, Laura; Chubb, Mark Henry; Bostock, Julian; Rogers, Jan; Rosenthal, Eric

    2016-02-01

    Epicardial pacemaker implantation is the favored approach in children weighing pacemaker implantation in neonates and infants from 1987. To date there have been no long-term follow-up reports of what is for many a controversial strategy. Between 1987 and 2003, 37 neonates and infants-median age 6.7 months (1 day to 3 years) and median weight 4.6 kg (2.7-10 kg)-had a permanent transvenous pacing system implanted. Pacing leads were placed into the right ventricular apex/outflow tract through a subclavian vein puncture with a redundant loop in the atrium. Three patients were lost to follow-up, 4 patients died from complications of cardiac surgery, and 2 patients had their system removed. At long-term follow-up in 28 patients at a median of 17.2 (range, 11.2-27.4) years, 10 patients have a single chamber ventricular pacemaker, 14 a dual chamber pacemaker, 3 a biventricular pacemaker, and 1 has a single chamber implantable cardioverter defibrillator. Subclavian vein patency was assessed in 26 patients. The overall subclavian vein occlusion rate was 10 of 13 (77%) 5 kg during long-term follow-up. After a median of 14.3 (range, 13.4-17.6) years of pacing, 7 patients continue with their original lead. Transvenous pacing in infants <10 kg results in encouraging short- and long-term clinical outcomes. Subclavian vein occlusion remains an important complication, occurring predominantly in those weighing <5 kg. © 2016 American Heart Association, Inc.

  20. Clinical predictors and prognostic significance of electrical storm in patients with implantable cardioverter defibrillators.

    Science.gov (United States)

    Brigadeau, François; Kouakam, Claude; Klug, Didier; Marquié, Christelle; Duhamel, Alain; Mizon-Gérard, Frédérique; Lacroix, Dominique; Kacet, Salem

    2006-03-01

    Insufficient data exists regarding predictors of electrical storms (ES) and clinical outcome in patients treated with an implantable cardioverter defibrillator (ICD). The purpose of this study was to delineate a subgroup of patients likely to experience ES and to determine the impact of ES on mortality in ICD recipients. Baseline characteristics of 307 ICD-treated patients were retrospectively analysed. ES was defined as two or more ventricular tachyarrhythmias within 24 h leading to an immediate electrical therapy (antitachycardia pacing and/or shock), separated by a period of sinus rhythm. Clinical characteristics and survival of 123 patients experiencing a total of 294 episodes of ES (median 2 ES/patient, range 1-9), were compared with those of 184 ES-free patients during a median follow-up of 826 days (inter-quartile 1141 days). Median actuarial duration for the first ES occurrence after ICD implant was 1417 days [95% confidence interval (CI) 1061-2363] with a median follow-up of 816 days (7-4642 days) in ES-free patients. Univariate analysis identified older age, depressed left ventricular ejection fraction (LVEF), ventricular tachycardia (VT) as index arrhythmia, chronic renal failure and absence of lipid-lowering drugs as variables significantly associated with an increased risk of ES. Multivariable Cox analysis confirmed an independent predictive value for chronic renal failure [hazard ratio (HR) 1.54, 95% CI 0.95-2.51, P=0.052], VT (HR 2.20, 95% CI 1.44-3.37, P=0.0003), and LVEF (HR 0.98, 95% CI 0.97-0.99, P=0.027). In contrast, diabetics (HR 0.49, 95% CI 0.27-0.90, P=0.022) were less affected by ES. There was no difference in survival between both groups. ES is frequent but does not increase mortality in ICD's recipients. Patients with severe systolic dysfunction, chronic renal failure and VT as initial arrhythmia are likely to experience ES. Diabetics are less affected by ES.

  1. Implantable cardioverter defibrillator therapy in pediatric and congenital heart disease patients: a single tertiary center experience in Korea

    Directory of Open Access Journals (Sweden)

    Bo Kyung Jin

    2013-03-01

    Full Text Available Purpose: The use of implantable cardioverter defibrillators (ICDs to prevent sudden cardiac death is increasing in children and adolescents. This study investigated the use of ICDs in children with congenital heart disease. Methods: This retrospective study was conducted on the clinical characteristics and effectiveness of ICD implantation at the department of pediatrics of a single tertiary center between 2007 and 2011. Results: Fifteen patients underwent ICD implantation. Their mean age at the time of implantation was 14.5±5.4 years (range, 2 to 22 years. The follow-up duration was 28.9±20.4 months. The cause of ICD implantation was cardiac arrest in 7, sustained ventricular tachycardia in 6, and syncope in 2 patients. The underlying disorders were as follows: ionic channelopathy in 6 patients (long QT type 3 in 4, catecholaminergic polymorphic ventricular tachycardia [CPVT] in 1, and J wave syndrome in 1, cardiomyopathy in 5 patients, and postoperative congenital heart disease in 4 patients. ICD coils were implanted in the pericardial space in 2 children (ages 2 and 6 years. Five patients received appropriate ICD shock therapy, and 2 patients received inappropriate shocks due to supraventricular tachycardia.During follow-up, 2 patients required lead dysfunction-related revision. One patient with CPVT suffered from an ICD storm that was resolved using sympathetic denervation surgery. Conclusion: The overall ICD outcome was acceptable in most pediatric patients. Early diagnosis and timely ICD implantation are recommended for preventing sudden death in high-risk children and patients with congenital heart disease.

  2. Inverse Relation between Condition of Heart Failure and Intrathoracic Impedance Measured by Implantable Cardioverter Defibrillator—A case report—

    Directory of Open Access Journals (Sweden)

    Kohei Matsushita, MD

    2005-01-01

    Full Text Available The patient was a 78-year-old man with dilated cardiomyopathy. His cardio-thoracic ratio was 60.4% and left ventricular ejection fraction (LVEF was 33%. He had been repeatedly admitted for congestive heart failure. He underwent implantation of an implantable cardioverter-defibrillator (ICD for ventricular fibrillation. We compared the values of BNP and shock impedance stored by the ICD. The correlation coefficient (p-value between BNP and shock impedance was −0.700 (p < 0.0005, increase of BNP and shock impedance was −0.778 (p < 0.0001, percent increase of BNP and shock impedance was −0.767 (p < 0.0005. In conclusion, there is an inverse relation between BNP and shock impedance, and measurements of shock impedance may be useful in the management of congestive heart failure.

  3. Use of PTFE patch for pericardial closure after minimal invasive LVAD implantation.

    Science.gov (United States)

    Mohite, Prashant N; Sabashnikov, Anton; Popov, Aron F; Fatullayev, Javid; Simon, André R

    2016-07-01

    The left ventricular assist device (LVAD) is now a routine therapy for advanced heart failure. The thoracotomy approach for LVAD implantation, in which the left ventricle is approached through a pericardial rent, is becoming popular. We demonstrate closure of the pericardial rent with a polytetrafluoroethylene (PTFE) patch and its advantages. © The Author(s) 2015.

  4. Use of Prothrombin Complex Concentrate in Patients during Heart Transplantation after Implantation of a Left Ventricular Mechanical Support System

    Directory of Open Access Journals (Sweden)

    V. V. Lomivorotov

    2012-01-01

    Full Text Available Heart transplantation in patients after implantation of mechanical cardiac support devices entails an extremely high risk for perioperative bleeding. Recombinant activated coagulation factor VII is presently used to reduce the volume of bleeding in this patient group. There are parallel data on its administration-induced thromboembolic events in the literature. This paper describes a case of using a prothrombin complex concentrate in a patient during explantation of a left ventricular bypass system and subsequent orthotopic heart transplantation in the presence of significant hypocoagulation. At the end of a surgery, 1200 IU of the agent was used at a remaining bleeding rate of more than 1000 ml/hour. Within the first 24 hours after surgery, the rate of discharge drainage was less than 100 ml/hour. A control plain chest X-ray study revealed massive left-sided hydrothorax on day 2 postsurgery. The left pleural cavity was revised under thoracoscopic guidance and 1000 ml of blood clots were evacuated. Although the administration of prothrombin complex concentrate did not guard against re-intervention, its use seems a promising strategy in life-threatening bleedings in patients after explantation of mechanical cardiac support devices. Further multicenter investigations are required to determine the efficacy and safety of prothrom-bin complex concentration in cardiac surgery. Key words: Recombinant activated coagulation factor VII, prothrombin complex concentration, mechanical cardiac support device, orthotopic heart transplantation.

  5. Trans* Leadership.

    Science.gov (United States)

    Jourian, T J; Simmons, Symone L

    2017-06-01

    Focusing on emerging literature on trans* and gender-nonconforming students and their leadership, this chapter outlines the ways trans* students are engaged in leadership in educational institutions and outside of them and discusses implications for staff and faculty regarding how to support and engage these students and their leadership. © 2017 Wiley Periodicals, Inc., A Wiley Company.

  6. The Syncardia™ total artificial heart: in vivo, in vitro, and computational modeling studies

    Science.gov (United States)

    Slepian, Marvin J.; Alemu, Yared; Soares, João Silva; Smith, Richard G.; Einav, Shmuel; Bluestein, Danny

    2014-01-01

    The SynCardia™ total artificial heart (TAH) is the only FDA-approved TAH in the world. The SynCardia™ TAH is a pneumatically driven, pulsatile system capable of flows of >9 L/min. The TAH is indicated for use as a bridge to transplantation (BTT) in patients at imminent risk of death from non-reversible bi-ventricular failure. In the Pivotal US approval trial the TAH achieved a BTT rate of >79%. Recently a multi-center, post-market approval study similarly demonstrated a comparable BTT rate. A major milestone was recently achieved for the TAH, with over 1100 TAHs having been implanted to date, with the bulk of implantation occurring at an ever increasing rate in the past few years. The TAH is most commonly utilized to save the lives of patients dying from end-stage bi-ventricular heart failure associated with ischemic or non-ischemic dilated cardiomyopathy. Beyond progressive chronic heart failure, the TAH has demonstrated great efficacy in supporting patients with acute irreversible heart failure associated with massive acute myocardial infarction. In recent years several diverse clinical scenarios have also proven to be well served by the TAH including severe heart failure associated with advanced congenital heart disease. failed or burned-out transplants, infiltrative and restrictive cardiomyopathies and failed ventricular assist devices. Looking to the future a major unmet need remains in providing total heart support for children and small adults. As such, the present TAH design must be scaled to fit the smaller patient, while providing equivalent, if not superior flow characteristics, shear profiles and overall device thrombogenicity. To aid in the development of a new “pediatric,” TAH an engineering methodology known as “Device Thrombogenicity Emulation (DTE)”, that we have recently developed and described, is being employed. Recently, to further our engineering understanding of the TAH, as steps towards next generation designs we have: (1

  7. Microvolt T-wave alternans and autonomic nervous system parameters can be helpful in the identification of low-arrhythmic risk patients with ischemic left ventricular systolic dysfunction.

    Science.gov (United States)

    Daniłowicz-Szymanowicz, Ludmiła; Kaufmann, Damian; Rozwadowska, Katarzyna; Kempa, Maciej; Lewicka, Ewa; Raczak, Grzegorz

    2018-01-01

    The role of implantable cardioverter-defibrillator (ICD) placement in the primary prevention of sudden cardiac death (SCD) in all consecutive patients with left ventricular ejection fraction (LVEF) ≤ 35% is still a matter of hot debate due to the fact that the population of these patients is highly heterogeneous in terms of the SCD risk. Nevertheless, reduced LVEF is still the only established criterion during qualification of patients for ICD implantation in the primary prevention of SCD, therefore identification of persons with particularly high risk among patients with LVEF ≤35% is currently of lesser importance. More important seems to be the selection of individuals with relatively low risk of SCD in whom ICD implantation can be safely postponed. The aim of the study was to determine whether well-known, non-invasive parameters, such as microvolt T-wave alternans (MTWA), baroreflex sensitivity (BRS) and short-term heart rate variability (HRV), can be helpful in the identification of low-arrhythmic risk patients with ischemic left ventricular systolic dysfunction. In 141 patients with coronary artery disease and LVEF ≤ 35%, MTWA testing, as well as BRS and short-term HRV parameters, were analysed. During 34 ± 13 months of follow-up 37 patients had arrhythmic episode (EVENT): SCD, non-fatal sustained ventricular arrhythmia (ventricular tachycardia [VT] or ventricular fibrillation [VF]), or adequate high-voltage ICD intervention (shock) due to a rapid ventricular arrhythmia ≥200/min. LVEF, non-negative MTWA (MTWA_non-neg), BRS and low frequency power in normalized units (LFnu) turned out to be associated with the incidence of EVENT in univariate Cox analysis. The cut-off values for BRS and LFnu that most accurately distinguished between patients with and without EVENT were 3 ms/mmHg and 23, respectively. The only variable that provided 100% negative predictive value (NPV) for EVENT was negative MTWA result (MTWA_neg), but solely for initial 12 months of

  8. Reliable porcine coronary model of chronic total occlusion using copper wire stents and bioabsorbable levo-polylactic acid polymer.

    Science.gov (United States)

    Sim, Doo Sun; Jeong, Myung Ho; Cha, Kyoung Rae; Park, Suk Ho; Park, Jong Oh; Shin, Young Min; Shin, Heungsoo; Hong, Young Joon; Ahn, Youngkeun; Schwartz, Robert S; Kang, Jung Chaee

    2012-12-01

    Chronic total occlusion (CTO) remains a challenge in interventional cardiology. We investigated the feasibility and reliability of copper wire stents and levo-polylactic acid (l-PLA) as a means of CTO induction in a porcine model. In one group of 20 swine, copper stents were crimped on a 3.0mm angioplasty balloon and inserted into the mid-left anterior descending coronary artery (LAD). In the other group of 20 swine, l-PLA was wrapped on a guidewire and pushed into the distal LAD with a 3.0mm balloon catheter to induce embolization. Of 20 swine which underwent copper stent implantation, 13 died of stent thrombosis. In the remaining 7 swine, total or near total occlusion with collateral circulation was observed at 5 weeks. Of 20 swine which underwent l-PLA embolization, 4 died of ventricular fibrillation during or shortly after the procedure. Serial histopathologic studies showed complete absorption of the polymer with replacement by fibrotic tissue approximately 4 weeks following the polymer implantation. CTO could be reliably induced in porcine coronary arteries by copper stents and l-PLA. These models may support investigation of new percutaneous devices to facilitate CTO interventions. Copyright © 2012 Japanese College of Cardiology. Published by Elsevier Ltd. All rights reserved.

  9. Late outcomes of subcostal exchange of the HeartMate II left ventricular assist device: a word of caution.

    Science.gov (United States)

    Yu, Sarah N; Takayama, Hiroo; Han, Jiho; Garan, Arthur R; Kurlansky, Paul; Yuzefpolskaya, Melana; Colombo, Paolo C; Naka, Yoshifumi; Takeda, Koji

    2018-04-10

    Previous studies have shown the usefulness of the subcostal exchange of the HeartMate II left ventricular assist device for device malfunction. However, long-term data are still limited. Between March 2004 and July 2017, 41 of 568 (7.2%) patients who had received a HeartMate II implant at our institution had a device exchange via a subcostal incision. We summarized early and late outcomes. Forty-one patients had a total of 48 subcostal pump exchanges. Indications for device exchange included device thrombosis (n = 31, 76%), driveline infection (n = 2, 5%) and driveline injury (n = 8, 19%). All of the procedures were successful, and there were no in-hospital deaths. A Kaplan-Meier survival curve showed 30-day and 1-year survival rates after subcostal exchange of 100% and 94.6%, respectively. However, 10 (25%) patients had left ventricular assist device-related infections following subcostal exchange that included 7 pump pocket infections and 3 driveline infections. Freedom from left ventricular assist device-related infection at 1 year after subcostal exchange was 79.3%. Thirteen (32%) patients had device malfunction due to pump thrombosis that required a 2nd device exchange. Seven patients had recurrent thrombosis. Three (7%) patients had a stroke. Freedom from device thrombosis and from a stroke event at 1 year was 74.4%. Subcostal pump exchange can be safely performed. However, there is a substantial risk of infection and recurrent thrombosis. Careful follow-up for late complications is mandatory.

  10. Stress induced right ventricular dysfunction: An indication of reversible right ventricular ischaemia

    International Nuclear Information System (INIS)

    Underwood, S.R.; Walton, S.; Emanuel, R.W.; Swanton, R.H.; Campos Costa, D.; Laming, P.J.; Ell, P.J.

    1987-01-01

    Stress induced changes in left ventricular ejection fraction are widely used in the detection and assessment of coronary artery disease. This study demonstrates that right ventricular dysfunction may also occur, and assesses its significance in terms of coronary artery anatomy. This study involved 14 normal subjects and 26 with coronary artery disease investigated by equilibrium radionuclide ventriculography, at rest and during maximal dynamic exercise. Mean normal resting right ventricular ejection fraction (RVEF) was 0.40 (SD 0.118), and all normal subjects increased RVEF with stress (mean ΔRVEF+0.13 SD 0.099). Mean ΔRVEF in the subjects with coronary artery disease was significantly lower at 0.00 (SD 0.080), but there was overlap between the two groups. The largest falls in RVEF were seen if the right coronary artery was occluded without retrograde filling. In this subgroup with the most severely compromised right ventricular perfusion (nine subjects), RVEF always fell with stress, and mean ΔRVEF was -0.08 (SD 0.050). There was no significant correlation between ΔLVEF and ΔRVEF, implying that the right ventricular dysfunction was due to right ventricular ischaemia, rather than secondary to left ventricular dysfunction. Stress induced right ventricular ischaemia can therefore be detected readily by radionuclide ventriculography. (orig.)

  11. Biotransformation of trans-1-chloro-3,3,3-trifluoropropene (trans-HCFO-1233zd)

    International Nuclear Information System (INIS)

    Schmidt, Tobias; Bertermann, Rüdiger; Rusch, George M.; Tveit, Ann; Dekant, Wolfgang

    2013-01-01

    trans-1-Chloro-3,3,3-trifluoropropene (trans-HCFO-1233zd) is a novel foam blowing and precision cleaning agent with a very low impact for global warming and ozone depletion. trans-HCFO-1233zd also has a low potential for toxicity in rodents and is negative in genotoxicity testing. The biotransformation of trans-HCFO-1233zd and kinetics of metabolite excretion with urine were assessed in vitro and in animals after inhalation exposures. For in vitro characterization, liver microsomes from rats, rabbits and humans were incubated with trans-HCFO-1233zd. Male Sprague Dawley rats and female New Zealand White rabbits were exposed to 2,000, 5,000 and 10,000 ppm for 6 h and urine was collected for 48 h after the end of the exposure. Study specimens were analyzed for metabolites using 19 F NMR, LC-MS/MS and GC/MS. S-(3,3,3-trifluoro-trans-propenyl)-glutathione was identified as predominant metabolite of trans-HCFO-1233zd in all microsomal incubation experiments in the presence of glutathione. Products of the oxidative biotransformation of trans-HCFO-1233zd were only minor metabolites when glutathione was present. In rats, both 3,3,3-trifluorolactic acid and N-acetyl-(3,3,3-trifluoro-trans-propenyl)-L-cysteine were observed as major urinary metabolites. 3,3,3-Trifluorolactic acid was not detected in the urine of rabbits. Quantitation showed rapid excretion of both metabolites in both species (t 1/2 1/2 < 6 h). ► Glutathione adduct as predominant in vitro metabolite in all tested species. ► Toxic metabolites could not be detected in any great extent

  12. Biotransformation of trans-1-chloro-3,3,3-trifluoropropene (trans-HCFO-1233zd)

    Energy Technology Data Exchange (ETDEWEB)

    Schmidt, Tobias [Institut für Toxikologie, Universität Würzburg, Versbacher Str. 9, 97078 Würzburg (Germany); Bertermann, Rüdiger [Institut für Anorganische Chemie, Universität Würzburg, Am Hubland, 97074 Würzburg (Germany); Rusch, George M.; Tveit, Ann [Honeywell, P.O. Box 1057, Morristown, NJ 07962-1057 (United States); Dekant, Wolfgang, E-mail: dekant@toxi.uni-wuerzburg.de [Institut für Toxikologie, Universität Würzburg, Versbacher Str. 9, 97078 Würzburg (Germany)

    2013-05-01

    trans-1-Chloro-3,3,3-trifluoropropene (trans-HCFO-1233zd) is a novel foam blowing and precision cleaning agent with a very low impact for global warming and ozone depletion. trans-HCFO-1233zd also has a low potential for toxicity in rodents and is negative in genotoxicity testing. The biotransformation of trans-HCFO-1233zd and kinetics of metabolite excretion with urine were assessed in vitro and in animals after inhalation exposures. For in vitro characterization, liver microsomes from rats, rabbits and humans were incubated with trans-HCFO-1233zd. Male Sprague Dawley rats and female New Zealand White rabbits were exposed to 2,000, 5,000 and 10,000 ppm for 6 h and urine was collected for 48 h after the end of the exposure. Study specimens were analyzed for metabolites using {sup 19}F NMR, LC-MS/MS and GC/MS. S-(3,3,3-trifluoro-trans-propenyl)-glutathione was identified as predominant metabolite of trans-HCFO-1233zd in all microsomal incubation experiments in the presence of glutathione. Products of the oxidative biotransformation of trans-HCFO-1233zd were only minor metabolites when glutathione was present. In rats, both 3,3,3-trifluorolactic acid and N-acetyl-(3,3,3-trifluoro-trans-propenyl)-L-cysteine were observed as major urinary metabolites. 3,3,3-Trifluorolactic acid was not detected in the urine of rabbits. Quantitation showed rapid excretion of both metabolites in both species (t{sub 1/2} < 6 h) and the extent of biotransformation of trans-HCFO-1233zd was determined as approximately 0.01% of received dose in rabbits and approximately 0.002% in rats. trans-HCFO-1233zd undergoes both oxidative biotransformation and glutathione conjugation at very low rates. The low extent of biotransformation and the rapid excretion of metabolites formed are consistent with the very low potential for toxicity of trans-HCFO-1233zd in mammals. - Highlights: ► No lethality and clinical signs were observed. ► Glutathione S-transferase and cytochrome P-450 dependent

  13. The need for multisectoral food chain approaches to reduce trans fat consumption in India.

    Science.gov (United States)

    Downs, Shauna M; Singh, Archna; Gupta, Vidhu; Lock, Karen; Ghosh-Jerath, Suparna

    2015-07-22

    The World Health Organization (WHO) recommends virtually eliminating trans fat from the global food supply. Although several high-income countries have successfully reduced trans fat levels in foods, low- and middle-income countries such as India face additional challenges to its removal from the food supply. This study provides a systems analysis of the Indian food chain to assess intervention options for reducing trans fat intake in low-income consumers. Data were collected at the manufacturer, retailer and consumer levels. Qualitative interviews were conducted with vanaspati manufacturers (n = 13) and local food vendors (n = 44). Laboratory analyses (n = 39) of street foods/snacks sold by the vendors were also conducted. Trans fat and snack intakes were also examined in low-income consumers in two rural villages (n = 260) and an urban slum (n = 261). Manufacturers of vanaspati described reducing trans fat levels as feasible but identified challenges in using healthier oils. The fat content of sampled oils from street vendors contained high levels of saturated fat (24.7-69.3 % of total fat) and trans fat (0.1-29.9 % of total fat). Households were consuming snacks high in trans fat as part of daily diets (31 % village and 84.3 % of slum households) and 4 % of rural and 13 % of urban households exceeded WHO recommendations for trans fat intakes. A multisectoral food chain approach to reducing trans fat is needed in India and likely in other low- and middle-income countries worldwide. This will require investment in development of competitively priced bakery shortenings and economic incentives for manufacturing foods using healthier oils. Increased production of healthier oils will also be required alongside these investments, which will become increasingly important as more and more countries begin investing in palm oil production.

  14. Powdered activated carbon adsorption of two fishy odorants in water: Trans,trans-2,4-heptadienal and trans,trans-2,4-decadienal.

    Science.gov (United States)

    Li, Xin; Wang, Jun; Zhang, Xiaojian; Chen, Chao

    2015-06-01

    Powdered activated carbon (PAC) adsorption of two fishy odorants, trans,trans-2,4-heptadienal (HDE) and trans,trans-2,4-decadienal (DDE), was investigated. Both the pseudo first-order and the pseudo second-order kinetic models well described the kinetics curves, and DDE was more readily removed by PAC. In isotherm tests, both Freundlich and Modified Freundlich isotherms fitted the experimental data well. PAC exhibited a higher adsorption capacity for DDE than for HDE, which could be ascribed to the difference in their hydrophobicity. The calculated thermodynamic parameters (ΔG0, ΔH0, and ΔS0) indicated an exothermic and spontaneous adsorption process. PAC dosage, pH, and natural organic matter (NOM) presence were found to influence the adsorption process. With increasing PAC dosage, the pseudo first-order and pseudo second-order rate constants both increased. The value of pH had little influence on HDE or DDE molecules but altered the surface charge of PAC, and the maximum adsorption capacity occurred at pH9. The presence of NOM, especially the fraction with molecular weight less than 1k Dalton, hindered the adsorption. The study showed that preloaded NOM impaired the adsorption capacity of HDE or DDE more severely than simultaneously fed NOM did. Copyright © 2015. Published by Elsevier B.V.

  15. Late gadolinium enhancement by magnetic resonance explains adverse cardiac events in individuals with ventricular arrhythmia

    International Nuclear Information System (INIS)

    Courtis, J.; Vasallo, J.; Arabia, L.; Dimitroff, M.; Gonzalez, A.; Tibaldi, M.

    2012-01-01

    Objective: To determine whether the presence of late gadolinium enhancement (LGE) by cardiovascular magnetic resonance (CMR) predict adverse cardiac events in patients with ventricular arrhythmia. Methods: We selected 74 consecutive patients with symptomatic ventricular arrhythmia (premature ventricular contractions and ventricular tachycardia) and left ventricular ejection fraction (LVEF) >55% sent to CMR for evaluation of structural heart disease previously undetected by other complementary methods. LGE, systolic function and volumes of both ventricles were analyzed. At follow-up was assessed a combined end point: hospitalization for ventricular arrhythmia, appropriate implantable cardioverter-defibrillator therapy and cardiac death. Results: During a median follow up of 575 days (interquartile range 24-1120 days) and by analyzing the population according to the presence (n=9, 12%) or not (n=65, 88%) LGE was observed that the group with positive Gd had lower LVEF (58% vs. 66% respectively, p=0.01) and larger volumes (EDV: 185 ml vs. 123 ml respectively, p=0.01 and ESV: 81 ml vs. 42 ml respectively, p=0.01) than the other group. Two (22%) patients in the LGE + group vs. one (4%) of those without LGE showed the combined endpoint (p=0.01) and when performing a logistic regression analysis it was found that the LGE is a predictor of adverse cardiac events analyzed (p=0.029). Conclusions: In this consecutive series of patients with ventricular arrhythmia we demonstrate a strong association between myocardial LGE and adverse cardiac events; this supports the hypothesis that myocardial fibrosis is an important arrhythmogenic substrate. In addition, almost all individuals without LGE were free of events during follow-up suggesting that it is possible to identify through the CMR low-risk individuals who can be treated conservatively. (authors) [es

  16. General anaesthesia for insertion of an automated implantable cardioverter defibrillator in a child with Brugada and autism

    Directory of Open Access Journals (Sweden)

    Shwetal Goraksha

    2010-01-01

    Full Text Available A 14-year-old autistic boy presented with acute gastroenteritis and hypotension. The electrocardiogram showed a ventricular fibrillation rhythm - he went into cardiorespiratory arrest and was immediately resuscitated. On investigation, the electrocardiogram showed a partial right bundle branch block with a "coved" pattern of ST elevation in leads v 1 -v 3 . A provisional diagnosis of Brugada syndrome was made, for which an automated implantable cardioverter defibrillator (AICD implantation was advised. Although the automated implantable cardioverter defibrillator implantation is usually performed under sedation, because this was an autistic child, he needed general anaesthesia. We performed the procedure uneventfully under general anaesthesia and he was discharged after a short hospital stay.

  17. ["Let me tell you about my little box": phenomenological study on the experience of living with a totally implantable central venous catheter].

    Science.gov (United States)

    Mutti, Carolina; Fumagalli, Anna; Monni, Pierina; Rancati, Stefania; Rosi, Ivana Maria

    2016-01-01

    . "Let me tell you about my little box": phenomenological study on the experience of living with a totally implantable central venous catheter. Many variables impact on the choice to implant a totally implantable long-term central venous catheter's (Port), in spite of its proven efficacy. The patients' perception is pivotal, and only few qualitative studies dig deep into patients' feelings and experiences. To understand if, and how, the Port affects the patient's life. Qualitative phenomenological study based on semi-structured interviews on a convenience sample of patients implanted a Port, selected in an oncohematology Day Hospital in Milan. The analysis was carried out by three researchers with a phenomenological method. Four main themes, and sub-themes, emerged from twenty interviews. Relief, both physical and psychological; the process of the choice of inserting the Port and the importance of thinking about its positioning since the beginning of the treatment course; the symbol- the device reminds of the disease and its removal is of utmost importance; the technology progresses- the need of trust in the health care personnel and in their competences. The Port improved the patients' quality of life. The study allows some reflections on the need of considering the actual and future conditions of the patient to make a shared and informed choice.

  18. Ventricular Arrhythmic Storm after Initiating Sacubitril/Valsartan.

    Science.gov (United States)

    Vicent, Lourdes; Juárez, Miriam; Martín, Irene; García, Jorge; González-Saldívar, Hugo; Bruña, Vanesa; Devesa, Carolina; Sousa-Casasnovas, Iago; Fernández-Avilés, Francisco; Martínez-Sellés, Manuel

    Sacubitril/valsartan was approved recently for the treatment of patients with heart failure and reduced ejection fraction. We present 6 cases of ventricular arrhythmia, that occurred shortly after sacubitril/valsartan initiation, that required drug withdrawal. Other potential triggering factors of electrical storm were ruled out and, from the arrhythmic perspective, all of the patients were stable in the previous year. Our aim is to describe the possible association of sacubitril/valsartan with arrhythmic storm. This was an observational monocentric study performed in the first 7 months of sacubitril/valsartan commercialization in Spain (October 2016). All patients were included in the SUMA (Sacubitril/Varsartan Usado Ambulatoriamente en Madrid [Sacubitril/Valsartan Used in Outpatients in Madrid]) registry. Patients were consecutively enrolled on the day they started the drug. Ventricular arrhythmic storm was defined as ≥2 episodes of sustained ventricular arrhythmia or defibrillator therapy application in 24 h. From 108 patients who received the drug, 6 presented with ventricular arrhythmic storm (5.6%). Baseline characteristics were similar in the patients with and without ventricular arrhythmic storm. The total number of days that sacubitril/valsartan was administered to each patient was 5, 6, 44 (8 since titration), 84, 93, and 136 (105 since titration), respectively. Our data are not enough to infer a cause-and-effect relationship. Further investigations regarding a potential proarrhythmic effect of sacubitril/valsartan are probably needed. © 2018 S. Karger AG, Basel.

  19. Effect of trimetazidine on recurrent angina pectoris and left ventricular structure in elderly multivessel coronary heart disease patients with diabetes mellitus after drug-eluting stent implantation: a single-centre, prospective, randomized, double-blind study at 2-year follow-up.

    Science.gov (United States)

    Xu, Xiaohan; Zhang, Weijun; Zhou, Yujie; Zhao, Yingxin; Liu, Yuyang; Shi, Dongmei; Zhou, Zhiming; Ma, Hanying; Wang, Zhijian; Yu, Miao; Ma, Qian; Gao, Fei; Shen, Hua; Zhang, Jianwei

    2014-04-01

    Trimetazidine has been shown to improve angina pectoris and left ventricular (LV) function in diabetic patients with ischaemic cardiomyopathy. The objective of this study was to evaluate the effects of trimetazidine on recurrent angina pectoris and LV structure after drug-eluting stent (DES) implantation in elderly multivessel coronary heart disease (CHD) patients with diabetes mellitus (DM) and a left ventricular ejection fraction (LVEF) of ≥ 50 %. This was a single-centre, prospective, randomized, double-blind evaluation study. Between January 2010 and September 2010, 700 CHD patients with DM who were aged ≥ 65 years and undergoing coronary angiography at An Zhen Hospital (Beijing, China) were recruited and prospectively randomized to receive trimetazidine (20 mg three times daily) or placebo after DES implantation as an addition to conventional CHD treatment. The primary end points were the incidence of recurrent angina pectoris and measures of various echocardiographic parameters, which included LVEF. At 2-year follow-up, patients in the trimetazidine group (n = 255) showed significant improvements in the incidence (P = 0.024) and severity of angina pectoris, compared with the control group, as well as silent myocardial ischaemia (P = 0.009) and angina pectoris-free survival (P = 0.011). LV function and structure in trimetazidine-treated patients were relatively stable at 2-year follow-up, while they deteriorated in the control group (n = 255) with a significant difference between groups (all P angina pectoris as well as LV function and structure in elderly multivessel CHD patients with DM.

  20. Systolic ventricular filling.

    Science.gov (United States)

    Torrent-Guasp, Francisco; Kocica, Mladen J; Corno, Antonio; Komeda, Masashi; Cox, James; Flotats, A; Ballester-Rodes, Manel; Carreras-Costa, Francesc

    2004-03-01

    The evidence of the ventricular myocardial band (VMB) has revealed unavoidable coherence and mutual coupling of form and function in the ventricular myocardium, making it possible to understand the principles governing electrical, mechanical and energetical events within the human heart. From the earliest Erasistratus' observations, principal mechanisms responsible for the ventricular filling have still remained obscured. Contemporary experimental and clinical investigations unequivocally support the attitude that only powerful suction force, developed by the normal ventricles, would be able to produce an efficient filling of the ventricular cavities. The true origin and the precise time frame for generating such force are still controversial. Elastic recoil and muscular contraction were the most commonly mentioned, but yet, still not clearly explained mechanisms involved in the ventricular suction. Classical concepts about timing of successive mechanical events during the cardiac cycle, also do not offer understandable insight into the mechanism of the ventricular filling. The net result is the current state of insufficient knowledge of systolic and particularly diastolic function of normal and diseased heart. Here we summarize experimental evidence and theoretical backgrounds, which could be useful in understanding the phenomenon of the ventricular filling. Anatomy of the VMB, and recent proofs for its segmental electrical and mechanical activation, undoubtedly indicates that ventricular filling is the consequence of an active muscular contraction. Contraction of the ascendent segment of the VMB, with simultaneous shortening and rectifying of its fibers, produces the paradoxical increase of the ventricular volume and lengthening of its long axis. Specific spatial arrangement of the ascendent segment fibers, their interaction with adjacent descendent segment fibers, elastic elements and intra-cavitary blood volume (hemoskeleton), explain the physical principles

  1. Age at implantation and auditory memory in cochlear implanted children.

    Science.gov (United States)

    Mikic, B; Miric, D; Nikolic-Mikic, M; Ostojic, S; Asanovic, M

    2014-05-01

    Early cochlear implantation, before the age of 3 years, provides the best outcome regarding listening, speech, cognition an memory due to maximal central nervous system plasticity. Intensive postoperative training improves not only auditory performance and language, but affects auditory memory as well. The aim of this study was to discover if the age at implantation affects auditory memory function in cochlear implanted children. A total of 50 cochlear implanted children aged 4 to 8 years were enrolled in this study: early implanted (1-3y) n = 27 and late implanted (4-6y) n = 23. Two types of memory tests were used: Immediate Verbal Memory Test and Forward and Backward Digit Span Test. Early implanted children performed better on both verbal and numeric tasks of auditory memory. The difference was statistically significant, especially on the complex tasks. Early cochlear implantation, before the age of 3 years, significantly improve auditory memory and contribute to better cognitive and education outcomes.

  2. Can we conserve trans-resveratrol content and antioxidant activity during industrial production of chocolate?

    Science.gov (United States)

    Salvador, Izabela; Massarioli, Adna P; Silva, Anna Paula S; Malaguetta, Heloísa; Melo, Priscilla S; Alencar, Severino M

    2018-05-23

    Cocoa exhibits high content of phenolic compounds, among which trans-resveratrol stands out, associated with several bioactive activities such as antioxidant properties. Chocolate contains reduced amounts of these bioactive compounds due to losses during the production process. Therefore, this study aimed to assess changes in total phenolic content and specifically trans-resveratrol, as well as in the antioxidant activity of cocoa and its products during industrial production of chocolate. A total of ten different cocoa products were analyzed. The processes of fermentation and roasting caused significant loss of total phenolic compounds and antioxidant activity. However, due to high temperature, roasting had a major influence on this loss (71% for total phenolic compounds and 53% to 77% for antioxidant activity), except for trans-resveratrol. The content of trans-resveratrol formed after fermentation (9.8 μg kg -1 ) showed little variation during the processes, and it was detected in higher concentrations both in natural (11.4 μg kg -1 ) and in alkalized cocoa powder (13.5 μg kg -1 ). Alkalization of cocoa products led to loss of capacity of deactivating superoxide radical. These findings contribute to the optimization of the production process of chocolate and other food products containing cocoa and its derivatives aiming to better preserve their bioactive compounds. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  3. Prevalence, clinical significance, and natural history of left ventricular apical aneurysms in hypertrophic cardiomyopathy.

    Science.gov (United States)

    Maron, Martin S; Finley, John J; Bos, J Martijn; Hauser, Thomas H; Manning, Warren J; Haas, Tammy S; Lesser, John R; Udelson, James E; Ackerman, Michael J; Maron, Barry J

    2008-10-07

    Hypertrophic cardiomyopathy (HCM) is the most common genetic heart disease characterized by a diverse clinical and phenotypic spectrum. This study reports the prevalence, morphology, clinical course, and management of an underrecognized subgroup of HCM patients with left ventricular apical aneurysms. Of 1299 HCM patients, 28 (2%) were identified with left ventricular apical aneurysms, including a pair of identical twins. Aneurysms were recognized at a wide age range (26 to 83 years), including 12 patients (43%) who were rims, and were associated with transmural (and often more extensive) myocardial scarring identified by late gadolinium enhancement cardiovascular magnetic resonance. Apical aneurysms were recognized by echocardiography in only 16 of 28 patients (57%) but by cardiovascular magnetic resonance in the 12 patients undetected by echocardiography. Left ventricular chamber morphology varied; however, 19 patients (68%) showed an "hourglass" contour, with midventricular hypertrophy producing muscular narrowing and intracavitary gradients in 9 patients (74+/-42 mm Hg). Sarcomeric protein missense mutations known to cause other phenotypic expressions of HCM were present in 3 patients. Over 4.1+/-3.7 years of follow-up, 12 patients (43%) with left ventricular apical aneurysms experienced adverse disease complications (event rate, 10.5%/y), including sudden death, appropriate implantable cardioverter-defibrillator discharges, nonfatal thromboembolic stroke, and progressive heart failure and death. Patients with left ventricular apical aneurysms represent an underappreciated subset in the heterogeneous HCM disease spectrum with important clinical implications, often requiring a high index of suspicion and cardiovascular magnetic resonance for identification. Apical aneurysms in HCM are associated with substantial cardiovascular morbidity and mortality and raise novel treatment considerations.

  4. The Total Artificial Heart in End-Stage Congenital Heart Disease.

    Science.gov (United States)

    Villa, Chet R; Morales, David L S

    2017-01-01

    The development of durable ventricular assist devices (VADs) has improved mortality rates and quality of life in patients with end stage heart failure. While the use of VADs has increased dramatically in recent years, there is limited experience with VAD implantation in patients with complex congenital heart disease (CHD), despite the fact that the number of patients with end stage CHD has grown due to improvements in surgical and medical care. VAD use has been limited in patients with CHD and end stage heart failure due to anatomic (systemic right ventricle, single ventricle, surgically altered anatomy, valve dysfunction, etc.) and physiologic constraints (diastolic dysfunction). The total artificial heart (TAH), which has right and left sided pumps that can be arranged in a variety of orientations, can accommodate the anatomic variation present in CHD patients. This review provides an overview of the potential use of the TAH in patients with CHD.

  5. Three-Dimensional Electroanatomic Mapping System-Enhanced Cardiac Resynchronization Therapy Device Implantation: Results From a Multicenter Registry.

    Science.gov (United States)

    Del Greco, Maurizio; Maines, Massimiliano; Marini, Massimiliano; Colella, Andrea; Zecchin, Massimo; Vitali-Serdoz, Laura; Blandino, Alessandro; Barbonaglia, Lorella; Allocca, Giuseppe; Mureddu, Roberto; Marenna, Biondino; Rossi, Paolo; Vaccari, Diego; Chianca, Roberto; Indiani, Stefano; DI Matteo, Irene; Angheben, Carlo; Zorzi, Alessandro

    2017-01-01

    Cardiac resynchronization therapy (CRT) device implantation guided by an electroanatomic mapping system (EAMS) is an emerging technique that may reduce fluoroscopy and angiography use and provide information on coronary sinus (CS) electrical activation. We evaluated the outcome of the EAMS-guided CRT implantation technique in a multicenter registry. During the period 2011-2014 we enrolled 125 patients (80% males, age 74 [71-77] years) who underwent CRT implantation by using the EnSite system to create geometric models of the patient's cardiac chambers, build activation mapping of the CS, and guide leads positioning. Two hundred and fifty patients undergoing traditional CRT implantation served as controls. Success and complication rates, fluoroscopy and total procedure times in the overall study population and according to center experience were collected. Centers that performed ≥10 were defined as highly experienced. Left ventricular lead implantation was successful in 122 (98%) cases and 242 (97%) controls (P = 0.76). Median fluoroscopy time was 4.1 (0.3-10.4) minutes in cases versus 16 (11-26) minutes in controls (P < 0.001). Coronary sinus angiography was performed in 33 (26%) cases and 208 (83%) controls (P < 0.001). Complications occurred in 5 (4%) cases and 17 (7%) controls (P = 0.28). Median fluoroscopy time (median 11 minutes vs. 3 minutes, P < 0.001) and CS angiography rate (55% vs. 21%, P < 0.001) were significantly higher in low experienced centers, while success rate and complications rate were similar. EAMS-guided CRT implantation proved safe and effective in both high- and low-experienced centers and allowed to reduce fluoroscopy use by ≈75% and angiography rate by ≈70%. © 2016 Wiley Periodicals, Inc.

  6. Short- and long-term performance of a tripolar down-sized single lead for implantable cardioverter defibrillator treatment: a randomized prospective European multicenter study. European Endotak DSP Investigator Group.

    Science.gov (United States)

    Sandstedt, B; Kennergren, C; Schaumann, A; Herse, B; Neuzner, J

    1998-11-01

    A new, thinner (10 Fr) and more flexible, single-pass transvenous endocardial ICD lead, Endotak DSP, was compared with a conventional lead, Endotak C, as a control in a prospective randomized multicenter study in combination with a nonactive can ICD. A total of 123 patients were enrolled, 55 of whom received a down-sized DSP lead. Lead-alone configuration was successfully implanted in 95% of the DSP patients vs 88% in the control group. The mean defibrillation threshold (DFT) was determined by means of a step-down protocol, and was identical in the two groups, 10.5 +/- 4.8 J in the DSP group versus 10.5 +/- 4.8 J in the control group. At implantation, the DSP mean pacing threshold was lower, 0.51 +/- 0.18 V versus 0.62 +/- 0.35 V (p < 0.05) in the control group, and the mean pacing impedance higher, 594 +/- 110 omega vs 523 +/- 135 omega (p < 0.05). During the follow-up period, the statistically significant difference in thresholds disappeared, while the difference in impedance remained. Tachyarrhythmia treatment by shock or antitachycardia pacing (ATP) was delivered in 53% and 41%, respectively, of the patients with a 100% success rate. In the DSP group, all 28 episodes of polymorphic ventricular tachycardia or ventricular fibrillation were converted by the first shock as compared to 57 of 69 episodes (83%) in the control group (p < 0.05). Monomorphic ventricular tachycardias were terminated by ATP alone in 96% versus 94%. Lead related problems were minor and observed in 5% and 7%, respectively. In summary, both leads were safe and efficacious in the detection and treatment of ventricular tachyarrhythmias. There were no differences between the DSP and control groups regarding short- or long-term lead related complications.

  7. Implant Gigi One-Piece vs Two-Pieces dalam Praktek Sehari-Hari

    Directory of Open Access Journals (Sweden)

    Dian Lestari Kurnia

    2014-12-01

    prosedur bedah dan prosedur prostetik lebih sederhana. Desain ini juga meniadakan celah mikro pada perbatasan implant dan abutment. Desain implant gigi one-piece memiliki keterbatasan pada pilihan prosedur prostetik apabila dibandingkan dengan desain implant gigi two-pieces.   One-Piece Versus Two-pieces Tooth Implant In Daily Practice. Implant had been a gold standard to replace missing tooth. However, implant marketed today was considered complex, and needs a second surgery. Complications may occur such as screw loosening or fracture and the presence of micro gap at implant-abutment-junction that is found causing fixture failure. The one-piece-implant design may offer some advantages. Purpose: this paper was aimed to discuss the pros and cons of one-piece-implants and two-piece-implants. Case 1 A 43-year-old woman came to place an implant on #16. The available bone height was 5 mm. A trans alveolar sinus lift procedure was performed with 0,5 cc allograft. A 12 mm one-piece-implant was inserted. Case 2 A 24-year-old woman came to place an implant on #46. The available bone height was 12 mm and a 10 mm two-piece-implant was inserted. Discussion: One-piece-implant offers some advantage. It needs no second surgery, easier placement protocol, and more natural prosthetic procedures. The design is preventing the failure in implant-abutment-junction failure. The absence of micro gap in one-piece-implant seems superior in preventing crestal bone resorption. However, the prosthetic option was limited in one-piece-implant. Two-piece-implant offers more choices in prosthetic abutment. Conclusion: One-piece-implant was easier and provide simple protocol with limited choice on prosthetic.

  8. AbioCor totally implantable artificial heart. How will it impact hospitals?

    Science.gov (United States)

    2002-09-01

    Although heart transplantation remains the most effective treatment for severe heart failure, there are far fewer donor hearts available than there are patients who could benefit from them. One approach to addressing this shortfall is the total artificial heart, or TAH. To date, however, no TAH design has been able to achieve one of the ultimate goals of heart replacement: to allow a patient to live a reasonably normal life without being connected to external machinery. A new design, the AbioCor TAH developed by Abiomed Inc., may make this goal achievable. Thanks to a power system that transfers energy through the skin without the aid of wires, the AbioCor--currently undergoing clinical trials in the United States--allows the patient to be completely mobile. The lack of transcutaneous wires also eliminates the primary source of the infections that have plagued TAH patients in the past. Though it is not without drawbacks, the AbioCor could represent a crucial advance in TAH technology. In this Technology Overview, we describe the operation of the AbioCor and discuss its likely impact on hospitals if it is approved for marketing in the United States. We also discuss a related cardiac-support technology: ventricular assist devices (VADs), which may also be used for permanent cardiac support someday.

  9. Epicardial left ventricular lead placement for cardiac resynchronization therapy: optimal pace site selection with pressure-volume loops.

    Science.gov (United States)

    Dekker, A L A J; Phelps, B; Dijkman, B; van der Nagel, T; van der Veen, F H; Geskes, G G; Maessen, J G

    2004-06-01

    Patients in heart failure with left bundle branch block benefit from cardiac resynchronization therapy. Usually the left ventricular pacing lead is placed by coronary sinus catheterization; however, this procedure is not always successful, and patients may be referred for surgical epicardial lead placement. The objective of this study was to develop a method to guide epicardial lead placement in cardiac resynchronization therapy. Eleven patients in heart failure who were eligible for cardiac resynchronization therapy were referred for surgery because of failed coronary sinus left ventricular lead implantation. Minithoracotomy or thoracoscopy was performed, and a temporary epicardial electrode was used for biventricular pacing at various sites on the left ventricle. Pressure-volume loops with the conductance catheter were used to select the best site for each individual patient. Relative to the baseline situation, biventricular pacing with an optimal left ventricular lead position significantly increased stroke volume (+39%, P =.01), maximal left ventricular pressure derivative (+20%, P =.02), ejection fraction (+30%, P =.007), and stroke work (+66%, P =.006) and reduced end-systolic volume (-6%, P =.04). In contrast, biventricular pacing at a suboptimal site did not significantly change left ventricular function and even worsened it in some cases. To optimize cardiac resynchronization therapy with epicardial leads, mapping to determine the best pace site is a prerequisite. Pressure-volume loops offer real-time guidance for targeting epicardial lead placement during minimal invasive surgery.

  10. Implantation technique of the 50-cm3 SynCardia Total Artificial Heart: does size make a difference?

    Science.gov (United States)

    Spiliopoulos, Sotirios; Guersoy, Dilek; Dimitriou, Alexandros Merkourios; Koerfer, Reiner; Tenderich, Gero

    2015-01-01

    Despite downsizing, implantation technique of the 50-cm(3) SynCardia Total Artificial Heart and settings of the Companion driver remain unchanged. Owing to the absence of de-airing nipples, de-airing procedure is even more crucial and has to be performed carefully. © The Author 2015. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  11. Identification of non-HLA antibodies in ventricular assist device recipients

    Directory of Open Access Journals (Sweden)

    Sandy von Salisch

    2013-11-01

    Full Text Available Aims Recipients of ventricular assist devices (VADR have a higher incidence to develop antibodies (Abs against human leukocyte antigens (HLA. Non-HLA antibodies like major histocompatibility complex class I-related chain A (MICA and autoantibodies against angiotensin type 1 receptor (AT1R and endothelin receptor A (ETAR are also implicated in the pathogenesis of acute rejection and allograft vasculopathy. We monitored non-HLA- and HLA-Abs in VADR up to one year after implantation. Materials and methods Sera of 56 VADR (54.1±12.8 years old, 50 men were analyzed for Abs against HLA-, MICA-, AT1R- and ETAR several times over one year after implantation using ELISA and Luminex xMAP technology. Blood transfusions, gender and age were reviewed. Results Sera of 56 VADR (54.1±12.8 years old, 50 men were analyzed for Abs against HLA-, MICA-, AT1R- and ETAR several times over one year after implantation using ELISA and Luminex xMAP technology. Blood transfusions, gender and age were reviewed. Conclusion Beside HLA- and MICA-Abs, VADR showed high titres of Abs against AT1R or ETAR, which underlines the necessity for monitoring non-HLA antibodies in VADR prior heart transplantation.

  12. Correlation between trans and intra-thoracic impedance and conductance in patients with chronic heart failure.

    Science.gov (United States)

    Malfatto, Gabriella; Villani, Alessandra; Rosa, Francesco Della; Rella, Valeria; Oldani, Matteo; Giglio, Alessia; Facchini, Mario; Parati, Gianfranco

    2016-04-01

    In chronic heart failure, changes of intra-thoracic impedance (Z0IT) may suggest impending pulmonary congestion; a similar result has been found by measuring trans-thoracic conductance (TFCTT = 1/Z0 = 1/kΩ). We assumed that a relationship could exist between Z0IT and TFCTT. We collected 140 measurements from 70 patients carrying an implantable cardioverter-defibrillator/cardiac resynchronization device with the CareLink function (71 ± 9 years, New York Heart Association (NYHA) 2.4 ± 0.9, ejection fraction 31 ± 8%, optimal treatment); they were studied during system alarms and after appropriate treatment (diuretics and/or vasodilators, n = 42) or during clinical stability and at the time of a system alarm (n = 28); correspondent BNP values were obtained. We related Z0IT obtained by the device, with TFCTT obtained with a commercial system. A strong relationship was found between Z0IT and TFCTT. Changes in the variables after treatment or during worsening conditions were of the same direction and order of magnitude, and were related to BNP levels obtained simultaneously. Trans-thoracic conductance, similarly to intra-thoracic impedance, may noninvasively point to pulmonary congestion and be useful in patients not carrying an implanted device. The possibility of remotely obtaining this variable should be evaluated for the telemonitoring of heart failure patients.

  13. Homologous SV40 RNA trans-splicing: Special case or prime example of viral RNA trans-splicing?

    Directory of Open Access Journals (Sweden)

    Sushmita Poddar

    2014-06-01

    Full Text Available To date the Simian Virus 40 (SV40 is the only proven example of a virus that recruits the mechanism of RNA trans-splicing to diversify its sequences and gene products. Thereby, two identical viral transcripts are efficiently joined by homologous trans-splicing triggering the formation of a highly transforming 100 kDa super T antigen. Sequences of other viruses including HIV-1 and the human adenovirus type 5 were reported to be involved in heterologous trans-splicing towards cellular or viral sequences but the meaning of these events remains unclear. We computationally and experimentally investigated molecular features associated with viral RNA trans-splicing and identified a common pattern: Viral RNA trans-splicing occurs between strong cryptic or regular viral splice sites and strong regular or cryptic splice sites of the trans-splice partner sequences. The majority of these splice sites are supported by exonic splice enhancers. Splice sites that could compete with the trans-splicing sites for cis-splice reactions are weaker or inexistent. Finally, all but one of the trans-splice reactions seem to be facilitated by one or more complementary binding domains of 11 to 16 nucleotides in length which, however occur with a statistical probability close to one for the given length of the involved sequences. The chimeric RNAs generated via heterologous viral RNA trans-splicing either did not lead to fusion proteins or led to proteins of unknown function. Our data suggest that distinct viral RNAs are highly susceptible to trans-splicing and that heterologous viral trans-splicing, unlike homologous SV40 trans-splicing, represents a chance event.

  14. [Arrhythmogenic right ventricular cardiomyopathy. Case report and a brief literature review].

    Science.gov (United States)

    Izurieta, Carlos; Curotto-Grasiosi, Jorge; Rocchinotti, Mónica; Torres, María J; Moranchel, Manuel; Cañas, Sebastián; Cardús, Marta E; Alasia, Diego; Cordero, Diego J; Angel, Adriana

    2013-01-01

    A 51-year-old man was admitted to this hospital because of palpitations and a feeling of dizziness for a period of 2h. The electrocardiogram revealed a regular wide-QRS complex tachycardia at a rate of 250 beats per minute, with superior axis and left bundle branch block morphology without hemodynamically decompensation, the patient was cardioverted to sinus rhythm after the administration of a loading and maintenance dose of amiodarone. The elechtrophysiological study showed the ventricular origin of the arrhythmia. In order to diagnose the etiology of the ventricular tachycardia we performed a coronary arteriography that showed normal epicardial vessels, thus ruling out coronary disease. Doppler echocardiography revealed systolic and diastolic functions of both left and right ventricles within normal parameters, and normal diameters as well. A cardiac magnetic resonance with late enhancement was done, showing structural abnormalities of the right ventricle wall with moderate impairment of the ejection fraction, and a mild dysfunction of the left ventricle. The diagnosis of arrhythmogenic right ventricular cardiomyopathy was performed as 2 major Task Force criteria were met. We implanted an automatic cardioverter defibrillator as a prophylactic measure. The patient was discharged without complications. Copyright © 2012 Instituto Nacional de Cardiología Ignacio Chávez. Published by Masson Doyma México S.A. All rights reserved.

  15. Multicentre clinical trial experience with the HeartMate 3 left ventricular assist device: 30-day outcomes.

    Science.gov (United States)

    Zimpfer, Daniel; Netuka, Ivan; Schmitto, Jan D; Pya, Yuriy; Garbade, Jens; Morshuis, Michiel; Beyersdorf, Friedhelm; Marasco, Silvana; Rao, Vivek; Damme, Laura; Sood, Poornima; Krabatsch, Thomas

    2016-09-01

    The objective of this study was to describe the operative experience and 30-day outcomes of patients implanted with the HeartMate 3 Left Ventricular Assist System (LVAS) during the Conformité Européenne (CE) Mark clinical trial. Adult patients met inclusion and exclusion criteria defining advanced-stage heart failure and included the indications of bridge to transplant and destination therapy. Operative parameters, outcomes, adverse events, physical status and quality-of-life parameters were assessed in the first 30 days after LVAS implant. Fifty patients were implanted with the HeartMate 3 at 10 centres in 6 countries. The 30-day survival rate was 98%. The median operative and cardiopulmonary bypass times were 200 (range: 95-585) min and 84 (range: 47-250) min, respectively. Patients required transfusion with packed red blood cells (3.6 ± 2.3 units), fresh frozen plasma (6.5 ± 5 units) and platelets (2 ± 1 units). Six patients (12%) required reoperation for postoperative bleeding and 10 patients (20%) did not require blood transfusion. The median intensive care time was 6 days (range: 1-112 days) and the total hospital stay was 28 days (range: 14-116 days). The most common adverse events were bleeding (15, 30%), arrhythmia (14, 28%) and infection (10, 20%). There were 2 (4%) strokes. The 30-day outcomes following implantation of the HeartMate 3 demonstrates excellent survival with low adverse event rates. The LVAD performed as intended with no haemolysis or device failure. NCT02170363. HeartMate 3™ CE Mark Clinical Investigation Plan (HM3 CE Mark). © The Author 2016. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  16. Veno-venous extracorporeal membrane oxygenation using an innovative dual-lumen cannula following implantation of a total artificial heart.

    Science.gov (United States)

    Youdle, Jemma; Penn, Sarah; Maunz, Olaf; Simon, Andre

    2017-01-01

    We report our first clinical use of the new Protek Duo TM cannula for peripheral veno-venous extra-corporeal life support (ECLS). A 53-year-old male patient underwent implantation of a total artificial heart (TAH) for biventricular failure. However, due to the development of post-operative respiratory dysfunction, the patient required ECLS for six days.

  17. Implanted near-infrared spectroscopy for cardiac monitoring

    Science.gov (United States)

    Bhunia, Sourav K.; Cinbis, Can

    2011-02-01

    Implanted Cardioverter Defibrillator (ICD) provides one of the most effective therapies for the prevention of sudden cardiac death, but also delivers some high voltage shocks inappropriately, causing morbidity and mortality. Implanted near-infrared spectroscopy (NIRS) may augment ICD arrhythmia detection by monitoring skeletal muscle perfusion. A two-wavelength, single-distance, continuous-wave implanted NIRS has been evaluated in-vivo. A weighted difference of the changes in attenuation at two wavelengths, across the isobestic point of the hemoglobin spectra, was taken to be the microvascular oxygenation trend indicator (O2 Index). Although the exact weight depends on the local vascular distribution and their oxygen levels, the hypothesis that a constant weight may be adequate for hemodynamic trending during short arrhythmic episodes, was tested. The sensor was implanted subcutaneously both on fresh tissue and inside scar tissue that formed around a pre-existing implant, in 3 animals each. Attenuations were recorded at 660 and 890 nm during normal sinus rhythm (NSR) and induced ventricular fibrillation (VF). The slope of the O2 Index over 10 seconds was computed for 7 NSR and 8 VF episodes in fresh and 13 NSR and 15 VF episodes in scar tissue pockets. The mean O2 Index slope was significantly different (p<0.0001) between NSR and VF rhythms for both the fresh and scar tissue pockets. Therefore implanted NIRS may be useful for preventing inappropriate detection of VF during electromagnetic interference, double counting of ECG T-wave as an R-wave, ICD lead failure, electrocardiographic aberrancy etc.

  18. Comparison of Venae Sectio vs. modified Seldinger Technique for Totally Implantable Access Ports; Portas-trial [ISRCTN:52368201

    Directory of Open Access Journals (Sweden)

    Luntz S

    2006-06-01

    Full Text Available Abstract Background The insertion of a Totally Implantable Access Port (TIAP is a routinely employed technique in patients who need a safe and permanent venous access. The number of TIAP implantations is increasing constantly mainly due to advanced treatment options for malignant diseases. Therefore it is important to identify the implantation technique which has the optimal benefit/risk ratio for the patient. Study design A single-centre, randomized, controlled superiority trial to compare two different TIAP implantation techniques. Sample size: 160 patients will be included and randomized intra-operatively. Eligibility criteria: Age equal or older than 18 years, patients scheduled for primary elective implantation of a TIAP in local anaesthesia and a signed informed consent. Primary endpoint: Primary success rate of the randomized technique. Intervention: Venae Sectio in combination with the Seldinger Technique (guide wire and a peel away sheath will be used to place a TIAP. Reference treatment: Conventional Venae Sectio will be used with a direct insertion of the TIAP without guide wire or peel away sheath. Duration of study: Approximately 20 months. Organisation/Responsibility The trial will be conducted in compliance with the protocol and in accordance with the moral, ethical, and scientific principles governing clinical research as set out in the Declaration of Helsinki (1989 and Good Clinical Practice (GCP. The trial will also be carried out in keeping with local and regulatory requirements. The Klinisches Studienzentrum Chirurgie (KSC – Centre of Clinical Trials in Surgery at the Department of Surgery, University Hospital Heidelberg is responsible for planning and conduction of the trial. Documentation of patient's data will be accomplished via electronical Case Report Files (eCRF with MACRO®-Software by the KSC. Randomization, data management, monitoring and biometry are provided by the independent Koordinierungszentrum f

  19. Ventricular Assist Device implant (AB 5000 prototype cannula: In vitro assessment of MRI issues at 3-Tesla

    Directory of Open Access Journals (Sweden)

    Valencerina Samuel

    2008-05-01

    Full Text Available Abstract Purpose To evaluate MRI issues at 3-Tesla for a ventricular assist device (VAD. Methods The AB5000 Ventricle with a prototype Nitinol wire-reinforced In-Flow Cannula and Out-Flow Cannula attached (Abiomed, Inc., Danvers, MA was evaluated for magnetic field interactions, heating, and artifacts at 3-Tesla. MRI-related heating was assessed with the device in a gelled-saline-filled, head/torso phantom using a transmit/received RF body coil while performing MRI at a whole body averaged SAR of 3-W/kg for 15-min. Artifacts were assessed for the main metallic component of this VAD (atrial cannula using T1-weighted, spin echo and gradient echo pulse sequences. Results The AB5000 Ventricle with the prototype In-Flow Cannula and Out-Flow Cannula attached showed relatively minor magnetic field interactions that will not cause movement in situ. Heating was not excessive (highest temperature change, +0.8°C. Artifacts may create issues for diagnostic imaging if the area of interest is in the same area or close to the implanted metallic component of this VAD (i.e., the venous cannula. Conclusion The results of this investigation demonstrated that it would be acceptable for a patient with this VAD (AB5000 Ventricle with a prototype Nitinol wire-reinforced In-Flow Cannula and Out-Flow Cannula attached to undergo MRI at 3-Tesla or less. Notably, it is likely that the operation console for this device requires positioning a suitable distance (beyond the 100 Gauss line or in the MR control room from the 3-Tesla MR system to ensure proper function of the VAD.

  20. Aorto-Right Ventricular Tunnel in Transposition of the Great Arteries

    Directory of Open Access Journals (Sweden)

    Antonio F. Corno

    2018-02-01

    Full Text Available Aorto-ventricular tunnel is an extremely rare congenital heart defect, consisting of failure of attachment of an aortic leaflet along the semilunar hinge. In all published reports the leaflet involved was either the right coronary leaflet, most frequently, or the left coronary leaflet, in most of the cases opening toward the left ventricle, with only one-eighth of the reported cases communicating with the right ventricle. Treatment of the aorto-ventricular tunnel has been anecdotally reported by interventional closure with a device and more frequently with surgical approach, either as an isolated malformation or as associated lesions. To the best of our knowledge, the presence of an aorto-ventricular tunnel of the non-adjacent aortic leaflet in transposition of the great arteries has never been reported. We have observed an aorto-ventricular tunnel involving the non-adjacent leaflet of the aortic root, which after arterial switch became the pulmonary root. The patient presented 18 years after the arterial switch with progressive dilatation of the right ventricle due to severe degree of pulmonary valve regurgitation, confirmed by echocardiography and cardiac MRI. Indication for surgery was given with the plan for a pulmonary valve implantation. Because of the intra-operative finding of disconnection of the anterior leaflet of the pulmonary valve (former aortic valve along the semilunar hinge, the surgical plan was modified and the anterior leaflet was attached to the valve annulus, with subsequent plasty in correspondence with the right and left commissurae to reduce the size of the dilated annulus to normal diameter. The post-operative course was uneventful, with extubation after few hours and discharge 4 days after surgery, with echocardiography showing trivial degree of pulmonary valve regurgitation. The patient remains in good conditions 6 months after surgery.

  1. Effect of Extruding Full-Fat Soy Flakes on Trans Fat Content

    Directory of Open Access Journals (Sweden)

    Hongxia Feng

    2014-01-01

    Full Text Available To evaluate the effects of extrusion process on the trans fatty acids (TFAs formation in soybean crude oils, three different extrusion parameters, namely, extrusion temperature (80–160°C, feed moisture (10–26%, and screw speed (100–500 rpm, were carried out. It was found that only five different types of TFAs were detected out using gas chromatography-mass spectrometry. Before the extrusion started, the initial amount of total TFAs was 3.04 g/100 g. However, after extruding under every level of any variable, the total amounts of TFAs were significantly higher than those in the control sample (P<0.05. For example, taking the effect of extrusion temperature into account, we can find that the highest amount of total of trans fatty acid (TTFA was 1.62 times the amount of that in the control sample, whereas the lowest amount of TTFA was 1.54 times the amount of that in the control sample. Importantly, it was observed that the amounts of every type of trans fatty acid were not continuously increasing with the increase of the level of any extrusion variable. This phenomenon demonstrated that the formation and diversification were intricate during extruding process and need to be further studied.

  2. Exercise physiology, testing, and training in patients supported by a left ventricular assist device.

    Science.gov (United States)

    Loyaga-Rendon, Renzo Y; Plaisance, Eric P; Arena, Ross; Shah, Keyur

    2015-08-01

    The left ventricular assist device (LVAD) is an accepted treatment alternative for the management of end-stage heart failure. As we move toward implantation of LVADs in less severe cases of HF, scrutiny of functional capacity and quality of life becomes more important. Patients demonstrate improvements in exercise capacity after LVAD implantation, but the effect is less than predicted. Exercise training produces multiple beneficial effects in heart failure patients, which would be expected to improve quality of life. In this review, we describe factors that are thought to participate in the persistent exercise impairment in LVAD-supported patients, summarize current knowledge about the effect of exercise training in LVAD-supported patients, and suggest areas for future research. Copyright © 2015 International Society for Heart and Lung Transplantation. Published by Elsevier Inc. All rights reserved.

  3. Clinical performance of different DF-4 implantable cardioverter defibrillator leads.

    Science.gov (United States)

    Sarrazin, Jean-François; Philippon, François; Sellier, Romain; André, Philippe; O'Hara, Gilles; Molin, Franck; Nault, Isabelle; Blier, Louis; Champagne, Jean

    2018-06-01

    Implantable cardioverter-defibrillator (ICD) DF-4 connectors have been introduced to facilitate defibrillator lead connection and to reduce the size of device header. There are limited data regarding the overall performance of those leads and no comparison between different ICD DF-4 leads. This is a cohort study of consecutive patients implanted with ICD DF-4 lead system at one University Centre between October 2010 and February 2015. A historical control group of patients with ICD DF-1 lead implantation was used for comparison. The following ICD DF-4 leads were evaluated: St. Jude Medical Durata 7122Q (St. Jude Medical, St. Paul, MN, USA), Medtronic Sprint Quattro Secure 6935 M (Medtronic Inc., Minneapolis, MN, USA), Boston Scientific Endotak Reliance 4-Site 0293 (Boston Scientific, Marlborough, MA, USA), and Boston Scientific Reliance 4-Front 0693. This study evaluated the acute and mid-term performances of those leads as well as complications. A total of 812 patients (age 63 ± 12 years, 80% male, left ventricular ejection fraction 31 ± 12%) underwent implantation of an ICD DF-4 lead. Acute and follow-up R-wave sensing and threshold were excellent. Compared to implantation, intrinsic R waves were higher at follow-up for Boston Scientific and Medtronic leads, and pacing lead impedances were lower for all leads at first follow-up (P < 0.001). The number of lead dislodgement or failure was similar between all leads. The estimated lead survival rates at 3 years were 95.6% for Boston Scientific Endotak 4-Site, 97.1% for Boston Scientific 4-Front, 97.7% for Medtronic Sprint Quattro, and 97.5% for St. Jude Durata (P  =  0.553). All ICD DF-4 leads had excellent acute and mid-term electrical performances. Longer follow-up will be necessary to confirm their sustained performance. © 2018 Wiley Periodicals, Inc.

  4. Right ventricle/interventricular septum electrophysiological anatomy (determination of optimal right ventricular lead placement

    Directory of Open Access Journals (Sweden)

    М. В. Диденко

    2015-10-01

    Full Text Available Notwithstanding a theoretically justified lead placement into the interventricular septum (IVS, the data from the clinical trials demonstrate somewhat controversial results. One of these controversies is the absence of consolidated criteria for positioning the electrode to deliver pacing from the interventricular septum (IVS area. The study describes anatomic features of RV and IVS with respect to the cardiac conduction system, normal ventricular excitation and electrode implantation techniques for continuous pacing. A comparative study of 73 specimens of cadaver hearts was carried out by using electro-anatomic 3D mapping of the heart, X-ray examination, computer-aided tomography, morphological and morphometric investigation. It was found out that the medium part of IVS in the septomarginal trabecula zone could be considered the best for continuous pacing. The criteria for the RV lead to be implanted in this zone were determined.

  5. Left ventricular outflow tract arrhythmias with divergent QRS morphology: mapping of different exits and ablation strategy.

    Science.gov (United States)

    Reithmann, Christopher; Fiek, Michael

    2018-01-01

    Ventricular arrhythmias (VAs) from the left ventricular outflow tract (LVOT) can have multiple exits exhibiting divergent ECG features. In a series of 131 patients with VAs with LVOT origin, 10 patients presented with divergent QRS morphologies. Multisite endo- and epicardial mapping of different exit sites was performed. The earliest ventricular activity of 23 LVOT VAs in 10 patients was detected in the endocardium of the LV in 7 patients, the aortic sinuses of Valsalva (SoV) in 3 patients, the distal coronary sinus in 6 patients, the anterior interventricular vein in 3 patients, and the posterior right ventricular outflow tract (RVOT) in 4 patients. Simultaneous elimination of two divergent QRS morphologies of LVOT VAs by ablation from a single site was achieved in 5 patients (aorto-mitral continuity in 3 patients, SoV and RVOT in each 1 patient) using a mean maximum ablation energy of 46 ± 5 W. Sequential ablation from two or three different sites, including trans-pericardial and distal coronary sinus ablation in each 2 patients, led to elimination of the divergent VA QRS morphologies in the other 5 patients. During the follow-up of 28 ± 29 months, 4 of the 10 patients had recurrence of at least one LVOT VA. A 43-year-old patient with muscular dystrophy Curschmann-Steinert had recurrence of sustained LVOT VTs and died of sudden cardiac death. Multisite mapping of different exit sites of LVOT VAs can guide ablation of intramural foci but the recurrence rate after initially successful ablation was high.

  6. Quantification of in vivo implant wear in total knee replacement from dynamic single plane radiography

    Science.gov (United States)

    Teeter, Matthew G.; Seslija, Petar; Milner, Jaques S.; Nikolov, Hristo N.; Yuan, Xunhua; Naudie, Douglas D. R.; Holdsworth, David W.

    2013-05-01

    An in vivo method to measure wear in total knee replacements was developed using dynamic single-plane fluoroscopy. A dynamic, anthropomorphic total knee replacement phantom with interchangeable, custom-fabricated components of known wear volume was created, and dynamic imaging was performed. For each frame of the fluoroscopy data, the relative location of the femoral and tibial components were determined, and the apparent intersection of the femoral component with the tibial insert was used to calculate wear volume, wear depth, and frequency of intersection. No difference was found between the measured and true wear volumes. The precision of the measurements was ±39.7 mm3 for volume and ±0.126 mm for wear depth. The results suggest the system is capable of tracking wear volume changes across multiple time points in patients. As a dynamic technique, this method can provide both kinematic and wear measurements that may be useful for evaluating new implant designs for total knee replacements.

  7. Quantification of in vivo implant wear in total knee replacement from dynamic single plane radiography

    International Nuclear Information System (INIS)

    Teeter, Matthew G; Naudie, Douglas D R; Holdsworth, David W; Seslija, Petar; Milner, Jaques S; Nikolov, Hristo N; Yuan Xunhua

    2013-01-01

    An in vivo method to measure wear in total knee replacements was developed using dynamic single-plane fluoroscopy. A dynamic, anthropomorphic total knee replacement phantom with interchangeable, custom-fabricated components of known wear volume was created, and dynamic imaging was performed. For each frame of the fluoroscopy data, the relative location of the femoral and tibial components were determined, and the apparent intersection of the femoral component with the tibial insert was used to calculate wear volume, wear depth, and frequency of intersection. No difference was found between the measured and true wear volumes. The precision of the measurements was ±39.7 mm 3 for volume and ±0.126 mm for wear depth. The results suggest the system is capable of tracking wear volume changes across multiple time points in patients. As a dynamic technique, this method can provide both kinematic and wear measurements that may be useful for evaluating new implant designs for total knee replacements. (paper)

  8. Prevalencia de hipertrofia ventricular izquierda en pacientes diabéticos Prevalence of left ventricular hypertrophy in diabetic patients

    Directory of Open Access Journals (Sweden)

    Diego Valarezo-Sevilla

    2013-03-01

    Full Text Available Con el objetivo de establecer la prevalencia de hipertrofia ventricular izquierda (HVI en pacientes con diabetes mellitus tipo 2 (DM, se realizó un estudio transversal en estos pacientes, estableciendo sus características antropométricas, presión arterial y control metabólico. Para evaluar la presencia de HVI se empleó ecocardiografía transtorácica. El estudio incluyó 91 pacientes, en los cuales la prevalencia de HVI fue de 63,7%, siendo más frecuente en mujeres que en varones (p=0,001. Adicionalmente, se encontró un 46,2% de pacientes con disfunción diastólica del ventrículo izquierdo. Se concluye que existe una importante prevalencia de HVI en pacientes diabéticos sin antecedentes de causas definidas de hipertrofia. No se encontró relación con sexo, control metabólico, IMC y tiempo de diagnósticoIn order to establish the prevalence of left ventricular hypertrophy (LVH in patients with type 2 diabetes mellitus, (DM a cross-sectional study was conducted in these patients studying their anthropometric characteristics, blood pressure and metabolic control. To evaluate the presence of LVH, a trans-thoracic echocardiogram was used. The study included 91 patients, finding a 63.7% prevalence of HVI, with women being more affected than men (p=0.001. Additionally, 46.2% of patients were found to have diastolic dysfunction of the left ventricle. We conclude that there is an important prevalence of LVH in diabetic patients without defined causes of hypertrophy. There was no association with sex, metabolic control, BMI and time of diagnosis

  9. Risk of pacemaker or implantable cardioverter defibrillator after radiotherapy for early-stage breast cancer in Denmark, 1982-2005

    DEFF Research Database (Denmark)

    Rehammar, Jens Christian; Johansen, Jens Brock; Jensen, Maj-Britt

    2017-01-01

    BACKGROUND AND PURPOSE: To examine the risk of cardiac conduction abnormalities or severe ventricular arrhythmias requiring implantation of a cardiac implantable electronic device (CIED), either a pacemaker or an implantable cardioverter-defibrillator, subsequent to breast cancer (BC) radiotherapy...... (RT). MATERIAL AND METHODS: All women treated for early-stage BC in Denmark from 1982 to 2005 were identified from the Danish Breast Cancer Cooperative Group. By record linkage to the Danish Pacemaker and ICD Registry information was retrieved on CIED implants subsequent to RT. Standardized incidence...... ratios (SIR) of CIED implantation were estimated for women receiving RT and compared to women not receiving RT for BC. Uni- and multivariate Poisson regression models were used to estimate incidence rate ratios (IRR) among irradiated women compared to non-irradiated. RESULTS: Of 44,423 BC patients, 179...

  10. Late gadolinium enhancement by magnetic resonance explains adverse cardiac events in individuals with ventricular arrhythmia; Realce tardío con gadolinio por resonancia magnética explica eventos cardíacos adversos en individuos con arritmia ventricular

    Energy Technology Data Exchange (ETDEWEB)

    Courtis, J.; Vasallo, J.; Arabia, L. [Departamento de Imágenes, Cardiología Intervencionista y Electrofisiología Instituto Oulton, Córdoba (Argentina); Dimitroff, M.; Gonzalez, A. [Facultad de Ciencias Exactas, Físicas y Naturales, Universidad Nacional de Córdoba, Códoba (Argentina); Tibaldi, M., E-mail: javiercourtis@oulton.com.ar [Técnicas no Invasivas y Arritmias, Instituto Modelo de Cardiología, Córdoba (Argentina)

    2012-07-01

    Objective: To determine whether the presence of late gadolinium enhancement (LGE) by cardiovascular magnetic resonance (CMR) predict adverse cardiac events in patients with ventricular arrhythmia. Methods: We selected 74 consecutive patients with symptomatic ventricular arrhythmia (premature ventricular contractions and ventricular tachycardia) and left ventricular ejection fraction (LVEF) >55% sent to CMR for evaluation of structural heart disease previously undetected by other complementary methods. LGE, systolic function and volumes of both ventricles were analyzed. At follow-up was assessed a combined end point: hospitalization for ventricular arrhythmia, appropriate implantable cardioverter-defibrillator therapy and cardiac death. Results: During a median follow up of 575 days (interquartile range 24-1120 days) and by analyzing the population according to the presence (n=9, 12%) or not (n=65, 88%) LGE was observed that the group with positive Gd had lower LVEF (58% vs. 66% respectively, p=0.01) and larger volumes (EDV: 185 ml vs. 123 ml respectively, p=0.01 and ESV: 81 ml vs. 42 ml respectively, p=0.01) than the other group. Two (22%) patients in the LGE + group vs. one (4%) of those without LGE showed the combined endpoint (p=0.01) and when performing a logistic regression analysis it was found that the LGE is a predictor of adverse cardiac events analyzed (p=0.029). Conclusions: In this consecutive series of patients with ventricular arrhythmia we demonstrate a strong association between myocardial LGE and adverse cardiac events; this supports the hypothesis that myocardial fibrosis is an important arrhythmogenic substrate. In addition, almost all individuals without LGE were free of events during follow-up suggesting that it is possible to identify through the CMR low-risk individuals who can be treated conservatively. (authors) [Spanish] Objetivo: determinar si la presencia de realce tardío con gadolinio (RTG) por resonancia magnética cardiovascular (RMC

  11. Preliminary experience with biodegradable implants for fracture fixation

    Directory of Open Access Journals (Sweden)

    Dhillon Mandeep

    2008-01-01

    Full Text Available Background: Biodegradable implants were designed to overcome the disadvantages of metal-based internal fixation devices. Although they have been in use for four decades internationally, many surgeons in India continue to be skeptical about the mechanical strength of biodegradable implants, hence this study. Materials and Methods: A prospective study was done to assess the feasibility and surgeon confidence level with biodegradable implants over a 12-month period in an Indian hospital. Fifteen fractures (intra-articular, metaphyseal or small bone fractures were fixed with biodegradable implants. The surgeries were randomly scheduled so that different surgeons with different levels of experience could use the implants for fixation. Results: Three fractures (one humeral condyle, two capitulum, were supplemented by additional K-wires fixation. Trans-articular fixator was applied in two distal radius and two pilon fractures where bio-pins alone were used. All fractures united, but in two cases the fracture displaced partially during the healing phase; one fibula due to early walking, and one radius was deemed unstable even after bio-pin and external fixator. Conclusions: Biodegradable -implants are excellent for carefully selected cases of intra-articular fractures and some small bone fractures. However, limitations for use in long bone fractures persist and no great advantage is gained if a "hybrid" composite is employed. The mechanical properties of biopins and screws in isolation are perceived to be inferior to those of conventional metal implants, leading to low confidence levels regarding the stability of reduced fractures; these implants should be used predominantly in fracture patterns in which internal fixation is subjected to minimal stress.

  12. Relação entre Fibrose e Arritmias Ventriculares na Cardiopatia Chagásica sem Disfunção Ventricular

    Directory of Open Access Journals (Sweden)

    Eduardo Marinho Tassi

    2014-06-01

    Full Text Available Fundamento: Pacientes com doença de Chagas com alteração segmentar apresentam pior prognóstico independentemente da fração de ejeção ventricular esquerda. A ressonância magnética cardíaca é atualmente o melhor método para detecção de alteração segmentar e para avaliação de fibrose miocárdica. Objetivo: Quantificar a fibrose, por meio do realce tardio, pela ressonância magnética cardíaca, em pacientes com doença de Chagas com fração de ejeção ventricular esquerda preservada ou minimamente comprometida (> 45% e detectar padrões de dependência entre fibrose, alteração segmentar e fração de ejeção ventricular esquerda na presença de arritmia ventricular. Métodos: Foram realizados eletrocardiograma, teste ergométrico, Holter e ressonância magnética cardíaca em 61 pacientes, separados em três grupos: (1 eletrocardiograma normal e ressonância magnética cardíaca sem alteração segmentar; (2 eletrocardiograma alterado e ressonância magnética cardíaca sem alteração segmentar; e (3 ressonância magnética cardíaca com alteração segmentar independentemente de alteração no eletrocardiograma. Resultados: O número de pacientes com arritmia ventricular em relação ao número total de pacientes em cada grupo, a porcentagem de fibrose e a fração de ejeção ventricular esquerda foram, respectivamente: no primeiro grupo, 4/26, 0,74% e 74,34%; no segundo grupo, 4/16, 3,96% e 68,5%; e no terceiro grupo, 11/19, 14,07% e 55,59%. Arritmia ventricular foi encontrada em 31,1% dos pacientes. Aqueles com e sem arritmia ventricular apresentaram fração de ejeção ventricular esquerda média de 59,87% e 70,18%, respectivamente, e fibrose de 11,03% e 3,01%, respectivamente. Das variáveis alteração segmentar, grupos, idade, fração de ejeção ventricular esquerda e fibrose, a última foi a única significativa para a presença de arritmia ventricular, com ponto de corte de 11,78% para massa fibrosada (p < 0

  13. "There's no chasing involved": cis/trans relationships, "tranny chasers," and the future of a sex-positive trans politics.

    Science.gov (United States)

    Tompkins, Avery Brooks

    2014-01-01

    This article adds to a small, but growing, body of work on trans sexualities and partnerships, and provides a much-needed inquiry into the complex and contested politics of desire when we take trans identities, bodies, and sexualities into account. Using digital ethnographic data from YouTube videos along with in-person observational data from LGBTQ and trans conferences in the U.S., Tompkins argues that a sex-positive trans politics cannot emerge in trans and trans-allied communities if the rhetoric of the "tranny chaser" continues to inform discourses of desire and attraction to trans people.

  14. Spatial and temporal variability in the trans-Pacific migration of Pacific bluefin tuna (Thunnus orientalis) revealed by archival tags

    Science.gov (United States)

    Fujioka, Ko; Fukuda, Hiromu; Tei, Yaoki; Okamoto, Suguru; Kiyofuji, Hidetada; Furukawa, Seishiro; Takagi, Junichi; Estess, Ethan; Farwell, Charles J.; Fuller, Daniel W.; Suzuki, Nobuaki; Ohshimo, Seiji; Kitagawa, Takashi

    2018-03-01

    Archival electronic tags were internally implanted in 713 age-0 Pacific bluefin tuna (PBF) caught in their nursery waters off the southern coast of Japan and in the East China Sea over an extended study period (1995-2015) to clarify the spatial and temporal variability of their trans-Pacific migration. Two hundred twenty-five of these tagged tuna were recaptured by fisheries (31.6%), and we successfully retrieved tag data from 14 of 21 individuals recovered in the Eastern pacific. Furthermore, one archival tag recovered in the Western Pacific revealed that the individual had performed a trans-Pacific migration, so in total 21 tagged PBF were shown to have migrated to the Eastern Pacific (2.9% of the total tags released). We successfully downloaded data from 15 of these 21 archival tags, which revealed that some age-1 PBF migrate rapidly (123.9 ± 82.8 km day-1) and directly from waters offshore of Japan to the eastern Pacific (160.0°E to 130.0°W), a journey that takes an average of 2.5 months (ranging from 1.2 to 5.5 months) through relatively cool waters (14.7 ± 2.0 °C). All juvenile PBF began their trans-Pacific migration shortly after exposure to cooler water temperatures (physiological challenge for this age class. Three patterns were identified in the timing of the departure of juvenile PBF from the western Pacific: departing 12-14 months post-hatch (N = 7) in early summer (May-July), departing 17-19 months post-hatch (N = 7) in late autumn (October-December), and departing 21 months post-hatch (N = 1) in late winter (February). The PBF tagged along the southern coast of Japan (SCJ) arrived in the eastern Pacific earlier than those tagged in the East China Sea (ECS), most likely due to the shorter travel distance. Additionally, the PBF that began their trans-Pacific migration in the earlier period remained in an offshore foraging zone (the Kuroshio-Oyashio transition region) for shorter periods (2.8 months on average) and at lower latitudes (35.0

  15. Avaliação do desempenho hemodinâmico do dispositivo de assistência ventricular InCor como substituto do coração esquerdo Analysis of the hemodynamic performance of the InCor ventricular assist device as a substitute for the left heart

    Directory of Open Access Journals (Sweden)

    Anderson BENÍCIO

    1999-07-01

    Full Text Available FUNDAMENTO: A assistência circulatória mecânica é uma opção terapêutica em casos de choque cardiogênio refratário ao tratamento farmacológico, sendo freqüentemente utilizada como ponte para o transplante cardíaco. OBJETIVO: Avaliar o desempenho do Dispositivo de Assistência Ventricular (DAV desenvolvido pela Bioengenharia do Instituto do Coração, quando implantado com substituto do coração esquerdo. CASUÍSTICA E MÉTODOS: Foram estudados 10 bezerros da raça Girolando com peso médio de 73 kg. O implante DAV-InCor foi realizado com a cânula de drenagem posicionada no átrio esquerdo (AE ou na ponta do ventrículo esquerdo (VE e a cânula de reposição implantada na aorta torácica descendente. As pressões do coração direito e esquerdo, débito cardíaco e o fluxo do DAV foram determinados antes e após a indução farmacológica de insuficiência miocárdica, na vigência de diferentes níveis de vácuo do sistema de drenagem. RESULTADOS: Com a drenagem no AE, os valores do fluxo do DAV foram de 2,2 ± 0,5 l/min na condição sem vácuo, 3,7 ± 0,4 l/min com vácuo de 10 mmHg, de 4,3 ± 0,4 com vácuo de 20 mmHg e de 4,8 ± 0,6 com vácuo de 30 mmHg. Os valores da pressão de AE foram de 11,7 ± 6; 9,8 ± 5,3, 8,5 ± 4,4 e 5,6 ± 3,3 mmHg nas mesmas condições, respectivamente. Com a cânula ventricular, o fluxo DAV foi de 4,2 ± 0,6 na condição sem vácuo e de 4,4 ± 0,7 com vácuo de 10 mmHg, sendo observados valores de pressão de AE de 11,1 ± 2 e 10,3 ± 3,5 mmHg nas duas condições. Esses resultados foram observados em condições hemodinâmicas semelhantes, sendo o fluxo do DAV responsável por um porcentual maior do débito cardíaco total conforme o nível de vácuo. Esse porcentual foi de 86 ± 13% com a cânula atrial e vácuo de 30 mmHg e de 97 ± 3% com a drenagem ventricular e vácuo de 10 mmHg. CONCLUSÕES: O DAV-InCor mostrou-se eficiente como substituto do ventrículo esquerdo. O desempenho deste

  16. Dual chamber arrhythmia detection in the implantable cardioverter defibrillator.

    Science.gov (United States)

    Dijkman, B; Wellens, H J

    2000-10-01

    Dual chamber implantable cardioverter defibrillator (ICD) technology extended ICD therapy to more than termination of hemodynamically unstable ventricular tachyarrhythmias. It created the basis for dual chamber arrhythmia management in which dependable detection is important for treatment and prevention of both ventricular and atrial arrhythmias. Dual chamber detection algorithms were investigated in two Medtronic dual chamber ICDs: the 7250 Jewel AF (33 patients) and the 7271 Gem DR (31 patients). Both ICDs use the same PR Logic algorithm to interpret tachycardia as ventricular tachycardia (VT), supraventricular tachycardia (SVT), or dual (VT+ SVT). The accuracy of dual chamber detection was studied in 310 of 1,367 spontaneously occurring tachycardias in which rate criterion only was not sufficient for arrhythmia diagnosis. In 78 episodes there was a double tachycardia, in 223 episodes SVT was detected in the VT or ventricular fibrillation zone, and in 9 episodes arrhythmia was detected outside the boundaries of the PR Logic functioning. In 100% of double tachycardias the VT was correctly diagnosed and received priority treatment. SVT was seen in 59 (19%) episodes diagnosed as VT. The causes of inappropriate detection were (1) algorithm failure (inability to fulfill the PRventricular rate above the SVT limit); and (3) algorithm limitations (atrial tachycardia with ventricular rate around the shortest programmable SVT limit and SVT redetection following VT therapy). Programming measures improved detection ability in 13 of 59 of inappropriately detected arrhythmias. Dual chamber detection algorithms evaluated in a subset of diagnostically difficult arrhythmias allow safe detection of double tachycardias but require further extension and programmability to

  17. The Use of Pediatric Ventricular Assist Devices in Children's Hospitals From 2000 to 2010: Morbidity, Mortality, and Hospital Charges.

    Science.gov (United States)

    Mansfield, Robert T; Lin, Kimberly Y; Zaoutis, Theoklis; Mott, Antonio R; Mohamad, Zeinab; Luan, Xianqun; Kaufman, Beth D; Ravishankar, Chitra; Gaynor, J William; Shaddy, Robert E; Rossano, Joseph W

    2015-07-01

    The use of ventricular assist devices has increased dramatically in adult heart failure patients. However, the overall use, outcome, comorbidities, and resource utilization of ventricular assist devices in pediatric patients have not been well described. We sought to demonstrate that the use of ventricular assist devices in pediatric patients has increased over time and that mortality has decreased. A retrospective study of the Pediatric Health Information System database was performed for patients 20 years old or younger undergoing ventricular assist device placement from 2000 to 2010. None. Four hundred seventy-five pediatric patients were implanted with ventricular assist devices during the study period: 69 in 2000-2003 (era 1), 135 in 2004-2006 (era 2), and 271 in 2007-2010 (era 3). Median age at ventricular assist device implantation was 6.0 years (interquartile range, 0.5-13.8), and the proportion of children who were 1-12 years old increased from 29% in era 1 to 47% in era 3 (p = 0.002). The majority of patients had a diagnosis of cardiomyopathy; this increased from 52% in era 1 to 72% in era 3 (p = 0.003). Comorbidities included arrhythmias (48%), pulmonary hypertension (16%), acute renal failure (34%), cerebrovascular disease (28%), and sepsis/systemic inflammatory response syndrome (34%). Two hundred forty-seven patients (52%) underwent heart transplantation and 327 (69%) survived to hospital discharge. Hospital mortality decreased from 42% in era 1 to 25% in era 3 (p = 0.004). Median hospital length of stay increased (37 d [interquartile range, 12-64 d] in era 1 vs 69 d [interquartile range, 35-130] in era 3; p interquartile range, $227,052-$853,318] in era 1 vs $1,577,983 [interquartile range, $874,463-$2,280,435] in era 3; p < 0.001). Factors associated with increased mortality include age less than 1 year (odds ratio, 2.04; 95% CI, 1.01-3.83), acute renal failure (odds ratio, 2.1; 95% CI, 1.26-3.65), cerebrovascular disease (odds ratio, 2.1; 95% CI, 1

  18. Tribo-biological deposits on the articulating surfaces of metal-on-polyethylene total hip implants retrieved from patients

    Science.gov (United States)

    Cui, Zhiwei; Tian, Yi-Xing; Yue, Wen; Yang, Lei; Li, Qunyang

    2016-06-01

    Artificial total hip arthroplasty (THA) is one of the most effective orthopaedic surgeries that has been used for decades. However, wear of the articulating surfaces is one of the key failure causes limiting the lifetime of total hip implant. In this paper, Fourier transform infrared spectroscopy (FTIR), X-ray photoelectron spectroscopy (XPS) and atomic force microscopy (AFM) were employed to explore the composition and formation mechanism of the tribo-layer on the articulating surfaces of metal-on-polyethylene (MoPE) implants retrieved from patients. Results showed that, in contrast to conventional understanding, the attached tribo-layer contained not only denatured proteins but also a fraction of polymer particles. The formation of the tribo-layer was believed to relate to lubrication regime, which was supposed to be largely affected by the nature of the ultra-high-molecule-weight-polyethylene (UHMWPE). Wear and formation of tribo-layer could be minimized in elasto-hydrodynamic lubrication (EHL) regime when the UHMWPE was less stiff and have a morphology containing micro-pits; whereas the wear was more severe and tribo-layer formed in boundary lubrication. Our results and analyses suggest that enhancing interface lubrication may be more effective on reducing wear than increasing the hardness of material. This finding may shed light on the design strategy of artificial hip joints.

  19. Development and testing of an algorithm to detect implantable cardioverter-defibrillator lead failure.

    Science.gov (United States)

    Gunderson, Bruce D; Gillberg, Jeffrey M; Wood, Mark A; Vijayaraman, Pugazhendhi; Shepard, Richard K; Ellenbogen, Kenneth A

    2006-02-01

    Implantable cardioverter-defibrillator (ICD) lead failures often present as inappropriate shock therapy. An algorithm that can reliably discriminate between ventricular tachyarrhythmias and noise due to lead failure may prevent patient discomfort and anxiety and avoid device-induced proarrhythmia by preventing inappropriate ICD shocks. The goal of this analysis was to test an ICD tachycardia detection algorithm that differentiates noise due to lead failure from ventricular tachyarrhythmias. We tested an algorithm that uses a measure of the ventricular intracardiac electrogram baseline to discriminate the sinus rhythm isoelectric line from the right ventricular coil-can (i.e., far-field) electrogram during oversensing of noise caused by a lead failure. The baseline measure was defined as the product of the sum (mV) and standard deviation (mV) of the voltage samples for a 188-ms window centered on each sensed electrogram. If the minimum baseline measure of the last 12 beats was algorithm to detect lead failures. The minimum baseline measure for the 24 lead failure episodes (0.28 +/- 0.34 mV-mV) was smaller than the 135 ventricular tachycardia (40.8 +/- 43.0 mV-mV, P <.0001) and 55 ventricular fibrillation episodes (19.1 +/- 22.8 mV-mV, P <.05). A minimum baseline <0.35 mV-mV threshold had a sensitivity of 83% (20/24) with a 100% (190/190) specificity. A baseline measure of the far-field electrogram had a high sensitivity and specificity to detect lead failure noise compared with ventricular tachycardia or fibrillation.

  20. [Percutaneous catheter-based implantation of artificial pulmonary valves in patients with congenital heart defects].

    Science.gov (United States)

    Wyller, Vegard Bruun; Aaberge, Lars; Thaulow, Erik; Døhlen, Gaute

    2011-07-01

    Percutaneous catheter-based implantation of artificial heart valves is a new technique that may supplement surgery and which may be used more in the future. We here report our first experience with implantation of artificial pulmonary valves in children with congenital heart defects. Eligible patients were those with symptoms of heart failure combined with stenosis and/or insufficiency in an established artificial right ventricular outflow tract. The valve was inserted through a catheter from a vein in the groin or neck. Symptoms, echocardiography, invasive measurements and angiography were assessed for evaluation of treatment effect. Our treatment results are reported for the period April 2007-September 2009. Ten patients (seven men and three women, median age 17 years) were assessed. The procedure reduced pressure in the right ventricle (p = 0.008) and resolved the pulmonary insufficiency in all patients. The median time in hospital was two days. No patients had complications that were directly associated with the implantation procedure. One patient developed a pseudoaneurysm in the femoral artery, another had a short-lasting fever two days after the procedure and one patient experienced a stent fracture that required surgery 9 months after the implantation. After 6 months all patients had a reduced pressure gradient in the right ventricular outflow tract (p = 0.008), the pulmonary insufficiency had improved (p = 0.006) and they all reported improval of symptoms. These results persisted for at least 24 months for the four patients who were monitored until then. Percutaneous catheter-based implantation of artificial pulmonary valves improves hemodynamics in the right ventricle of selected patients with congenital heart defects. A randomized controlled study should be undertaken to provide a stronger evidence-base for usefulness of this procedure.

  1. Estimation of left ventricular end diastolic pressure by tissue doppler imaging in patients with acute myocardial infarction

    International Nuclear Information System (INIS)

    Ali, M.; Abid, A.R.; Rehman, T.A.; Masood, A.; Sohail, S.

    2010-01-01

    Objective: To evaluate sensitivity and specificity of E / Ea > 10 for prediction of LVEDP > 15 mmHg in patients with coronary artery disease undergoing left heart catheterization. Materials and Methods: Sixty patients of acute transmural myocardial infarction at Jinnah Hospital Lahore were enrolled in study from December 2008 to December 2009. Patients with sinus rhythm were included in the study. Patients with valvular heart disease, complete right/left bundle branch block, Pacemaker dependence, Atrial fibrillation and Post mitral valve replacement were excluded. All patients were examined by performing trans thoracic Doppler echocardiography. The trans-mitral LV filling signal was traced manually and the following variables were obtained: peak early (E) and late (A) trans-mitral velocities, and E/A ratio. Tissue - Doppler derived indices were recorded at the lateral mitral annulus. These indices included systolic velocities (S'), early diastolic (Ea) velocities and late diastolic (Aa) velocities. Finally, the dimensionless index of E/Ea was calculated. All were averaged from at least three beats. Cardiac catheterization was performed via trans-femoral / trasradial route using six French (6F) sheaths. Left ventricular diastolic pressure was directly measured by fluid filled pigtail catheter attached to a pressure transducer. Results: Mean age of the study population was 56.8 +- 12.7 years. There were 47 (78.3%) males and 13 (21.7%) females. Diabetes mellitus was present in 12(20%), hypertension in 32 (53.3%), smoking in 35 (58.3%), dyslipidemia in 24 (40%). Anterior wall myocardial infarction occurred in 44 (73.3%) and inferior wall MI in 16 (26.7%). Grade I diastolic dysfunction was present in 22 (36.7%), Grade II in 31 (51.7%) and Grade III in 7 (11.7%) patients. E/E 15 in 9 (15%). Overall 21 patients were true positive, 6 were false positive, 25 were true negative and 8 were false negative. By applying 2 X 2 table sensitivity was 77.7%, specificity was 80

  2. Estimation of left ventricular end diastolic pressure by tissue doppler imaging in patients with acute myocardial infarction

    Energy Technology Data Exchange (ETDEWEB)

    Ali, M; Abid, A R; Rehman, T A; Masood, A; Sohail, S [Allama Iqbal Medical College/Jinnah Hospital, Lahore(Pakistan)

    2010-10-15

    Objective: To evaluate sensitivity and specificity of E / Ea > 10 for prediction of LVEDP > 15 mmHg in patients with coronary artery disease undergoing left heart catheterization. Materials and Methods: Sixty patients of acute transmural myocardial infarction at Jinnah Hospital Lahore were enrolled in study from December 2008 to December 2009. Patients with sinus rhythm were included in the study. Patients with valvular heart disease, complete right/left bundle branch block, Pacemaker dependence, Atrial fibrillation and Post mitral valve replacement were excluded. All patients were examined by performing trans thoracic Doppler echocardiography. The trans-mitral LV filling signal was traced manually and the following variables were obtained: peak early (E) and late (A) trans-mitral velocities, and E/A ratio. Tissue - Doppler derived indices were recorded at the lateral mitral annulus. These indices included systolic velocities (S'), early diastolic (Ea) velocities and late diastolic (Aa) velocities. Finally, the dimensionless index of E/Ea was calculated. All were averaged from at least three beats. Cardiac catheterization was performed via trans-femoral / trasradial route using six French (6F) sheaths. Left ventricular diastolic pressure was directly measured by fluid filled pigtail catheter attached to a pressure transducer. Results: Mean age of the study population was 56.8 +- 12.7 years. There were 47 (78.3%) males and 13 (21.7%) females. Diabetes mellitus was present in 12(20%), hypertension in 32 (53.3%), smoking in 35 (58.3%), dyslipidemia in 24 (40%). Anterior wall myocardial infarction occurred in 44 (73.3%) and inferior wall MI in 16 (26.7%). Grade I diastolic dysfunction was present in 22 (36.7%), Grade II in 31 (51.7%) and Grade III in 7 (11.7%) patients. E/E < 10 was observed in 31 (51.7%), 11 - 15 in 20 (33.3%) and > 15 in 9 (15%). Overall 21 patients were true positive, 6 were false positive, 25 were true negative and 8 were false negative. By

  3. TransAlta: More than a utility

    International Nuclear Information System (INIS)

    Mikalson, D.A.

    1991-01-01

    TransAlta Utilities Corporation is Canada's largest privately owned utility and is also a major coal mining company. In 1989, TransAlta produced 20.9% of all coal mined in Canada. A brief history of TransAlta is presented along with TransAlta's present coal operations and plans for the next three years. An overview is presented of how TransAlta Fuel Supply is organized to utilize contracted mining operation, engineering and environmental services and in-house capabilities. Recent strategic initiatives to improve organizational efficiency and the mining operations are discussed. These range from developing a common departmental vision to modifying major mining equipment. TransAlta's proactive role in clean coal combustion such as low NOx-SOx burner, integrated combined cycle gasification, and other energy research projects is reviewed. A summary is provided of recent participation of TransAlta in environmental management initiatives. Recent successes of TransAlta's unregulated subsidiary in the development of cogeneration facilities and the future of this area of business are discussed. 8 refs., 4 figs

  4. Trans-fatty acid consumption and heart rate variability in two separate cohorts of older and younger adults

    Science.gov (United States)

    Soares-Miranda, Luisa; Stein, Phyllis K; Imamura, Fumiaki; Sattelmair, Jacob; Lemaitre, Rozenn N; Siscovick, David S; Mota, Jorge; Mozaffarian, Dariush

    2014-01-01

    Background Trans-fatty acid (TFA) consumption is associated with risk of coronary heart disease, and trans-18:2, but not trans-18:1, in red blood cells membranes has been associated with sudden cardiac arrest. Abnormal heart rate variability (HRV) reflects autonomic dysfunction and predicts cardiac death. Relationships between TFA consumption and HRV remain under-studied. We determined whether total TFA consumption, as well as trans-18:1 and trans-18:2 TFA consumption, were independently associated with HRV in two independent cohorts in the US and Portugal. Methods and Results In two independent cohorts of older US adults (Cardiovascular Health Study ([CHS], age=72±5yrs, 1989/1995) and young Portuguese adults (Porto, age=19±2yrs, 2008/2010), we assessed habitual TFA intake by food frequency questionnaires in CHS (separately estimating trans-18:1 and trans-18:2) and multiple 24-hour recalls in Porto (estimating total TFA only, which in a subset correlated with circulating trans-18:2, but not trans-18:1, suggesting that we captured the former). HRV was assessed using 24-hour Holters in CHS (N=1,076) and repeated short-term (5-min) ECGs in Porto (N=160). We used multivariate-adjusted linear regression to relate TFA consumption to HRV cross-sectionally (CHS, Porto) and longitudinally (CHS). In CHS, higher trans-18:2 consumption was associated with lower 24-hour standard-deviation-of-all-normal-to-normal-intervals (SDNN) both cross-sectionally (−12%, 95%CI=6–19%, p=0.001) and longitudinally (−15%, 95%CI=4–25 %, p= 0.009), and lower 24-hour SDANN and SDNN-index (pHRV, in particular time-domain indices (SDNN, SDANN, SDNN-index; pHRV in both older and young adults. Trans-18:1 consumption is associated with more favorable HRV indices in older adults. Our results support the need to investigate potential HRV related mechanisms whereby trans-18:2 may increase arrhythmic risk. PMID:22772898

  5. Transcatheter Aortic Valve Implantation and Morbidity and Mortality-Related Factors: a 5-Year Experience in Brazil

    Directory of Open Access Journals (Sweden)

    André Luiz Silveira Souza

    2016-01-01

    Full Text Available Abstract Background: Transcatheter aortic valve implantation has become an option for high-surgical-risk patients with aortic valve disease. Objective: To evaluate the in-hospital and one-year follow-up outcomes of transcatheter aortic valve implantation. Methods: Prospective cohort study of transcatheter aortic valve implantation cases from July 2009 to February 2015. Analysis of clinical and procedural variables, correlating them with in-hospital and one-year mortality. Results: A total of 136 patients with a mean age of 83 years (80-87 underwent heart valve implantation; of these, 49% were women, 131 (96.3% had aortic stenosis, one (0.7% had aortic regurgitation and four (2.9% had prosthetic valve dysfunction. NYHA functional class was III or IV in 129 cases (94.8%. The baseline orifice area was 0.67 ± 0.17 cm2 and the mean left ventricular-aortic pressure gradient was 47.3±18.2 mmHg, with an STS score of 9.3% (4.8%-22.3%. The prostheses implanted were self-expanding in 97% of cases. Perioperative mortality was 1.5%; 30-day mortality, 5.9%; in-hospital mortality, 8.1%; and one-year mortality, 15.5%. Blood transfusion (relative risk of 54; p = 0.0003 and pulmonary arterial hypertension (relative risk of 5.3; p = 0.036 were predictive of in-hospital mortality. Peak C-reactive protein (relative risk of 1.8; p = 0.013 and blood transfusion (relative risk of 8.3; p = 0.0009 were predictive of 1-year mortality. At 30 days, 97% of patients were in NYHA functional class I/II; at one year, this figure reached 96%. Conclusion: Transcatheter aortic valve implantation was performed with a high success rate and low mortality. Blood transfusion was associated with higher in-hospital and one-year mortality. Peak C-reactive protein was associated with one-year mortality.

  6. TransCanada Corporation 2003 annual report

    International Nuclear Information System (INIS)

    2004-01-01

    This annual report presents financial information from TransCanada Corp., along with a review of its operations throughout 2003 and a summary of the how the company performed in terms of providing natural gas transmission and power services in North America. In 2003, TransCanada increased earnings from continuing operations by 7 per cent. It maintained a strong cash flow and continued to strengthen its balance sheet. More than 1.2 billion was invested and dividends were increased by 7 per cent in January 2004, for a total return to shareholders of 27 per cent, including dividends. In 2003, TransCanada also increased its ownership interest in Foothills Pipe Lines Ltd. to 100 per cent from 50 per cent. It secured a position in the Mackenzie Gas Pipeline Project and progressed the development of multiple liquefied natural gas projects in the northeast United States and eastern Canada. The company acquired 31.6 per cent interest in Bruce Power, adding nearly 1,500 megawatts base load generation to its portfolio. Plans are underway for cogeneration plants in Quebec, New Brunswick and Alberta. This report summarized the company's energy resource activities and presented an operations review as well as consolidated financial statements and common share information. This included the utility's assets, liabilities, revenues, expenses and cash flows. Revenue and expenditure statements were summarized by source. tabs., figs

  7. TransCanada Corporation 2004 annual report

    International Nuclear Information System (INIS)

    2005-01-01

    TransCanada is a leading North American energy company dealing with natural gas transmission, power generation and marketing opportunities. Financial information from TransCanada was presented in this annual report along with a review of its operations in 2004 and a summary of how the company performed in terms of providing natural gas transmission and power services in North America. In 2004, TransCanada increased earnings from continuing operations and maintained a strong cash flow and continued to strengthen its balance sheet. Achievements in 2004 included the acquisition of the Gas Transmission Northwest Pipeline System and the North Baja Pipeline System; the purchase of hydroelectric generation assets in New England with a total generating capacity of more than 500 MW; and the completed construction of two new gas-fired cogeneration plants, the 165 MW MacKay River facility in Alberta and the 90 MW Grandview facility in New Brunswick. The challenges in 2004 included the performance of the company's existing asset-based businesses and the new initiatives to produce another year of solid operating and financial results. This report summarized the company's energy resource activities and presented an operations review as well as consolidated financial statements and common share information. This included the utility's assets, liabilities, revenues, expenses and cash flows. Revenue and expenditure statements were summarized by source. tabs., figs

  8. Arrhythmia and conduction disorders in acute inferior myocardial infarction with right ventricular involvement

    International Nuclear Information System (INIS)

    Samadikhah, J.; Hakim, S.H.; Azarfarin, R.; Ghaffari, S.

    2007-01-01

    To assess the prognostic impact of Right Ventricular (RV) myocardial involvement in patients with inferior MI. One hundred seventy patients who were admitted to cardiac care unit of Madani Heart Hospital, Tabriz, Iran with the diagnosis of inferior MI with (group 1) or without (group 2) simultaneous involvement of RV were studied from 2005 to 2006. Patients presenting within 12 hours of symptom onset were eligible for inclusion. Those with simultaneous Anterior wall MI, patients undergoing primary percutaneous transluminal coronary angioplasty and those with renal impairment (creatinine >2 mg/dl) were excluded. Eighty eight percent of the patients with RVMI and 75% with isolated inferior MI had some type of arrhythmia. AV block occurred in 42% of the infarctions with RV involvement and only in 29% of the control group. Intra ventricular conduction disturbance (IVCD) also were more frequent in RVMI (29.4% VS 13.1%, p=0.021), especially the RBBB (20% VS 7.4%, P=0.003). Ventricular fibrillation (VF) was observed in 5.2% and 1.2% and ventricular tachycardia in 26% and 12.2% respectively. In 27% of patients with RVMI it was necessary to implant a pacemaker as compared to 10% in control group. Mortality was higher in the patients with inferior infarction extended to the RV (15.3% vs 3.5%., P=0.0001). There was not a meaningful difference in incidence of LBBB between group 1 and 2 (3.1% vs 2.9% P=0.9). Patients with inferior MI who also have RV myocardial involvement are at increased risk of death and arrhythmias. (author)

  9. The overloaded right heart and ventricular interdependence.

    Science.gov (United States)

    Naeije, Robert; Badagliacca, Roberto

    2017-10-01

    The right and the left ventricle are interdependent as both structures are nested within the pericardium, have the septum in common and are encircled with common myocardial fibres. Therefore, right ventricular volume or pressure overloading affects left ventricular function, and this in turn may affect the right ventricle. In normal subjects at rest, right ventricular function has negligible interaction with left ventricular function. However, the right ventricle contributes significantly to the normal cardiac output response to exercise. In patients with right ventricular volume overload without pulmonary hypertension, left ventricular diastolic compliance is decreased and ejection fraction depressed but without intrinsic alteration in contractility. In patients with right ventricular pressure overload, left ventricular compliance is decreased with initial preservation of left ventricular ejection fraction, but with eventual left ventricular atrophic remodelling and altered systolic function. Breathing affects ventricular interdependence, in healthy subjects during exercise and in patients with lung diseases and altered respiratory system mechanics. Inspiration increases right ventricular volumes and decreases left ventricular volumes. Expiration decreases both right and left ventricular volumes. The presence of an intact pericardium enhances ventricular diastolic interdependence but has negligible effect on ventricular systolic interdependence. On the other hand, systolic interdependence is enhanced by a stiff right ventricular free wall, and decreased by a stiff septum. Recent imaging studies have shown that both diastolic and systolic ventricular interactions are negatively affected by right ventricular regional inhomogeneity and prolongation of contraction, which occur along with an increase in pulmonary artery pressure. The clinical relevance of these observations is being explored. Published on behalf of the European Society of Cardiology. All rights

  10. Peri-implant bone strains and micro-motion following in vivo service: a postmortem retrieval study of 22 tibial components from total knee replacements.

    Science.gov (United States)

    Mann, Kenneth A; Miller, Mark A; Goodheart, Jacklyn R; Izant, Timothy H; Cleary, Richard J

    2014-03-01

    Biological adaptation following placement of a total knee replacements (TKRs) affects peri-implant bone mineral density (BMD) and implant fixation. We quantified the proximal tibial bone strain and implant-bone micro-motion for functioning postmortem retrieved TKRs and assessed the strain/micro-motion relationships with chronological (donor age and time in service) and patient (body weight and BMD) factors. Twenty-two tibial constructs were functionally loaded to one body weight (60% medial/40% lateral), and the bone strains and tray/bone micro-motions were measured using a digital image correlation system. Donors with more time in service had higher bone strains (p = 0.044), but there was not a significant (p = 0.333) contribution from donor age. Donors with lower peri-implant BMD (p = 0.0039) and higher body weight (p = 0.0286) had higher bone strains. Long term implants (>11 years) had proximal bone strains 900 µϵ that were almost twice as high as short term (implants 570 µϵ. Micro-motion was greater for younger donors (p = 0.0161) and longer time in service (p = 0.0008). Increased bone strain with long term in vivo service could contribute to loosening of TKRs by failure of the tibial peri-implant bone. © 2013 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  11. Antifibrillatory effects of renal denervation on ventricular fibrillation in a canine model of pacing-induced heart failure.

    Science.gov (United States)

    Luo, Qingzhi; Jin, Qi; Zhang, Ning; Huang, Shangwei; Han, Yanxin; Lin, Changjian; Ling, Tianyou; Chen, Kang; Pan, Wenqi; Wu, Liqun

    2018-01-01

    What is the central question of this study? In the present study, we investigated the effects of renal denervation on the vulnerability to ventricular fibrillation and the ventricular electrical properties in a rapid pacing-induced heart failure canine model. What is the main finding and its importance? Renal denervation significantly attenuated the process of heart failure and improved left ventricular systolic dysfunction, stabilized ventricular electrophysiological properties and decreased the vulnerability of the heart to ventricular fibrillation during heart failure. Thus, renal denervation can attenuate ventricular electrical remodelling and exert a potential antifibrillatory action in a pacing-induced heart failure canine model. In this study, we investigated the effects of renal denervation (RDN) on the vulnerability to ventricular fibrillation (VF) and the ventricular electrical properties in a canine model of pacing-induced heart failure (HF). Eighteen beagles were divided into the following three groups: control (n = 6), HF (n = 6) and HF+RDN (n = 6). Heart failure was induced by rapid right ventricular pacing. Renal denervation was performed simultaneously with the pacemaker implantation in the HF+RDN group. A 64-unipolar basket catheter was used to perform global endocardial mapping of the left ventricle. The restitution properties and dispersion of refractoriness were estimated from the activation recovery intervals (ARIs) by a pacing protocol. The VF threshold (VFT) was defined as the maximal pacing cycle length required to induce VF using a specific pacing protocol. The defibrillation threshold (DFT) was measured by an up-down algorithm. Renal denervation partly restored left ventricular systolic function and attenuated the process of HF. Compared with the control group, the VFT in the HF group was decreased by 27% (106 ± 8.0 versus 135 ± 10 ms, P Renal denervation significantly flattened the ventricular ARI restitution curve by 15% (1

  12. Taser X26 discharges in swine: ventricular rhythm capture is dependent on discharge vector.

    Science.gov (United States)

    Valentino, Daniel J; Walter, Robert J; Dennis, Andrew J; Margeta, Bosko; Starr, Frederic; Nagy, Kimberly K; Bokhari, Faran; Wiley, Dorion E; Joseph, Kimberly T; Roberts, Roxanne R

    2008-12-01

    Data from our previous studies indicate that Taser X26 stun devices can acutely alter cardiac function in swine. We hypothesized that most transcardiac discharge vectors would capture ventricular rhythm, but that other vectors, not traversing the heart, would fail to capture the ventricular rhythm. Using an Institutional Animal Care and Use Committee (IACUC) approved protocol, four Yorkshire pigs (25-36 kg) were anesthetized, paralyzed with succinylcholine (2 mg/kg), and then exposed to 10 second discharges from a police-issue Taser X26. For most discharges, the barbed darts were pushed manually into the skin to their full depth (12 mm) and were arranged in either transcardiac (such that a straight line connecting the darts would cross the region of the heart) or non-transcardiac vectors. A total of 11 different vectors and 22 discharge conditions were studied. For each vector, by simply rotating the cartridge 180-degrees in the gun, the primary current-emitting dart was changed and the direction of current flow during the discharge was reversed without physically moving the darts. Echocardiography and electrocardiograms (ECGs) were performed before, during, and after all discharges. p values captured immediately in 52.5% (31 of 59) of the discharges on the ventral surface of the animal. In each of these cases, capture of the ventricular rhythm with rapid ventricular contractions consistent with ventricular tachycardia (VT) or flutter was seen throughout the discharge. A total of 27 discharges were administered with transcardiac vectors and ventricular capture occurred in 23 of these discharges (85.2% capture rate). A total of 32 non-transcardiac discharges were administered ventrally and capture was seen in only eight of these (25% capture rate). Ventricular fibrillation (VF) was seen with two vectors, both of which were transcardiac. In the remaining animals, VT occurred postdischarge until sinus rhythm was regained spontaneously. For most transcardiac vectors

  13. Surgery for ventricular tachycardia in patients undergoing surgical ventricular restoration: the Karolinska approach.

    Science.gov (United States)

    Sartipy, Ulrik; Albåge, Anders; Insulander, Per; Lindblom, Dan

    2007-09-01

    This article presents a review on the efficacy of surgical ventricular restoration and direct surgery for ventricular tachycardia in patients with left ventricular aneurysm or dilated ischemic cardiomyopathy. The procedure includes a non-electrophysiologically guided subtotal endocardiectomy and cryoablation in addition to endoventricular patch plasty of the left ventricle. Coronary artery bypass surgery and mitral valve repair are performed concomitantly as needed. In our experience, this procedure yielded a 90% success rate in terms of freedom from spontaneous ventricular tachycardia, with an early mortality rate of 3.8%. A practical guide to the pre- and postoperative management of these patients is provided.

  14. [TRENDS OF PERMANENT PACEMAKER IMPLANTATION IN A SINGLE CENTER OVER A 20-YEAR PERIOD].

    Science.gov (United States)

    Antonelli, Dante; Ilan, Limor Bushar; Freedberg, Nahum A; Feldman, Alexander; Turgeman, Yoav

    2015-05-01

    To review the changes in permanent pacemaker implantation indications, pacing modes and patients' demographics over a 20-year period. We retrospectively retrieved data on patients who underwent first implantation of the pacemaker between 1-1-1991 and 31-12-2010. One thousand and nine (1,009) patients underwent a first pacemaker implantation during that period; 535 were men (53%), their mean age was 74.6±19.5 years; the highest rate of implanted pacemaker was in patients ranging in age from 70-79 years, however there was an increasing number of patients aged over 80 years. The median survival time after initial pacemaker implantation was 8 years. Syncope was the most common symptom (62.5%) and atrioventricular block was the most common electrocardiographic indication (56.4%) leading to pacemaker implantation. There was increased utilization of dual chamber and rate responsive pacemakers over the years. There was no difference regarding mode selection between genders. Pacemaker implantation rates have increased over a 20-year period. Dual chamber replaced most of the single ventricular chamber pacemaker and rate responsive pacemakers became the norm. The data of a small volume center are similar to those reported in pacemaker surveys of high volume pacemaker implantation centers. They confirm adherence to the published guidelines for pacing.

  15. Optimal Implantable Cardioverter Defibrillator Programming.

    Science.gov (United States)

    Shah, Bindi K

    Optimal programming of implantable cardioverter defibrillators (ICDs) is essential to appropriately treat ventricular tachyarrhythmias and to avoid unnecessary and inappropriate shocks. There have been a series of large clinical trials evaluating tailored programming of ICDs. We reviewed the clinical trials evaluating ICD therapies and detection, and the consensus statement on ICD programming. In doing so, we found that prolonged ICD detection times, higher rate cutoffs, and antitachycardia pacing (ATP) programming decreases inappropriate and painful therapies in a primary prevention population. The use of supraventricular tachyarrhythmia discriminators can also decrease inappropriate shocks. Tailored ICD programming using the knowledge gained from recent ICD trials can decrease inappropriate and unnecessary ICD therapies and decrease mortality.

  16. Association between ventricular pacing and persistent atrial fibrillation in patients indicated to elective pacemaker replacement: Results of the Prefer for Elective Replacement MVP (PreFER MVP) randomized study.

    Science.gov (United States)

    Ricci, Renato P; Botto, Giovanni Luca; Bénézet, Juan M; Nielsen, Jens Cosedis; De Roy, Luc; Piot, Olivier; Quesada, Aurelio; Quaglione, Raffaele; Vaccari, Diego; Mangoni, Lorenza; Grammatico, Andrea; Kozák, Milan

    2015-11-01

    Pacing in the right ventricle can cause a variety of detrimental effects, including atrial tachyarrhythmias (atrial tachycardia [AT]/atrial fibrillation [AF]). The purpose of this study was to evaluate the incidence and predictors of persistent AT/AF in patients with long-term exposure to ventricular pacing. In a multicenter international trial, 605 patients (age 75 ± 11 years, 240 women) referred for replacement of an implanted pacemaker or implantable cardioverter-defibrillator (ICD), with a history of high-percentage (>40%) ventricular pacing, were randomly allocated to standard dual-chamber pacing or managed ventricular pacing (MVP), a pacing modality that minimizes ventricular pacing. The main end-point of this secondary analysis of the PreFER MVP randomized study was persistent AT/AF, defined as ≥7 consecutive days with AT/AF or AT/AF interrupted by atrial cardioversion or AT/AF present during 2 consecutive follow-up visits. Persistent AT/AF was observed in 71 patients (11.7%) after 2 years of follow-up. At multivariable Cox regression analysis, prior AT/AF (hazard ratio [HR] 2.85, 95% confidence interval [CI] 1.20-6.22, P = .017) and ventricular pacing percentage, estimated in the first 3 months, ≥10% (HR 3.24, 95% 95% CI 1.13-9.31, P = .029) were independent predictors for persistent AT/AF. MVP was associated with persistent AT/AF risk (HR 3.41, 95% 95% CI 1.10-10.6, P = .024) in the subgroup of patients with baseline long PR interval (PR >230 ms) but not in the whole population. In pacemaker and ICD replacement patients, a high percentage of ventricular pacing is associated with higher risk of persistent AT/AF. Use of algorithms that minimize right ventricular pacing may benefit patients with normal spontaneous AV conduction but should be evaluated with caution in patients with long PR interval. Copyright © 2015 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  17. Control of Pollutants in the Trans-Boundary Area of Taihu Basin, Yangtze Delta

    Directory of Open Access Journals (Sweden)

    Xiao Wang

    2016-12-01

    Full Text Available This work focuses on pollution control in the trans-boundary area of Taihu Basin. Considering the unique characteristics of the river network in the study area, a new methodology of pollution control is proposed aiming at improving the water quality in the trans-boundary area and reducing conflicts between up and downstream regions. Based on monitoring data and statistical analysis, important trans-boundary cross sections identified by the regional government were selected as important areas for consideration in developing management objectives; using a 1-D mathematicmodel and an effective weight evaluation model, the trans-boundary effective control scope (TECS of the study area was identified as the scope for pollutant control; the acceptable pollution load was then estimated using an established model targeting bi-directional flow. The results suggest that the water environmental capacity for chemical oxygen demand (COD, in order to guarantee reaching the target water quality standard in the TECS, is 160,806 t/year, and amounts to 16,098 t/year, 3493 t/year, and 39,768 t/year for ammonia nitrogen, total nitrogen, and total phosphorus, respectively. Our study method and results have been incorporated into the local government management project, and have been proven to be useful in designing a pollution control strategy and management policy.

  18. [The reasonable use of right ventricular protection strategy in right ventricular outflow tract reconstruction].

    Science.gov (United States)

    Zhang, Y; Yuan, H Y; Liu, X B; Wen, S S; Xu, G; Cui, H J; Zhuang, J; Chen, J M

    2018-06-01

    As a result of right ventricular outflow tract reconstruction, which is the important and basic step of complex cardiac surgery, the blood flow of right ventricular outflow tract is unobstructed, while pulmonary valve regurgitation and right heart dysfunction could be happened. These problems are often ignored in early days, more and more cases of right heart dysfunction need clinical intervention, which is quite difficult and less effective. How to protect effectively the right ventricular function is the focus. At present main methods to protect the right ventricular function include trying to avoid or reduce length of right ventricular incision, reserving or rebuilding the function of the pulmonary valve, using growth potential material for surgery. The protection of the right ventricular function is a systemic project, it involves many aspects, single measures is difficult to provide complete protection, only the comprehensive use of various protection strategy, can help to improve the long-term prognosis.

  19. Preservation of keratinized mucosa around implants using a prefabricated implant-retained stent: a case-control study

    OpenAIRE

    Kim, Chang-Soon; Duong, Hieu Pham; Park, Jung-Chul; Shin, Hyun-Seung

    2016-01-01

    Purpose The aim of this study was to clinically assess the impact of a prefabricated implant-retained stent clipped over healing abutments on the preservation of keratinized mucosa around implants after implant surgery, and to compare it with horizontal external mattress sutures. Methods A total of 50 patients were enrolled in this study. In the test group, a prefabricated implant-retained stent was clipped on the healing abutment after implant surgery to replace the keratinized tissue bucco-...

  20. Facts about trans fats

    Science.gov (United States)

    Trans fat is a type of dietary fat . Of all the fats, trans fat is the worst for your health. Too much ... from solid margarine to soft margarine. Ask what type of fats foods are cooked in when you eat out ...

  1. General and acute care surgical procedures in patients with left ventricular assist devices.

    Science.gov (United States)

    Arnaoutakis, George J; Bittle, Gregory J; Allen, Jeremiah G; Weiss, Eric S; Alejo, Jennifer; Baumgartner, William A; Shah, Ashish S; Wolfgang, Christopher L; Efron, David T; Conte, John V

    2014-04-01

    Left ventricular assist devices (LVADs) have become common as a bridge to heart transplant as well as destination therapy. Acute care surgical (ACS) problems in this population are prevalent but remain ill-defined. Therefore, we reviewed our experience with ACS interventions in LVAD patients. A total of 173 patients who received HeartMate(®) XVE or HeartMate(®) II (HMII) LVADs between December 2001 and March 2010 were studied. Patient demographics, presentation of ACS problem, operative intervention, co-morbidities, transplantation, complications, and survival were analyzed. A total of 47 (27 %) patients underwent 67 ACS procedures at a median of 38 days after device implant (interquartile range 15-110), with a peri-operative mortality rate of 5 % (N = 3). Demographics, device type, and acuity were comparable between the ACS and non-ACS groups. A total of 21 ACS procedures were performed emergently, eight were urgent, and 38 were elective. Of 29 urgent and emergent procedures, 28 were for abdominal pathology. In eight patients, the cause of the ACS problem was related to LVADs or anticoagulation. Cumulative survival estimates revealed no survival differences if patients underwent ACS procedures (p = 0.17). Among HMII patients, transplantation rates were unaffected by an ACS intervention (p = 0.2). ACS problems occur frequently in LVAD patients and are not associated with adverse outcomes in HMII patients. The acute care surgeon is an integral member of a comprehensive approach to effective LVAD management.

  2. Antitachycardia pacing programming in implantable cardioverter defibrillator: A systematic review.

    Science.gov (United States)

    De Maria, Elia; Giacopelli, Daniele; Borghi, Ambra; Modonesi, Letizia; Cappelli, Stefano

    2017-05-26

    Implantable cardioverter defibrillator (ICD) programming involves several parameters. In recent years antitachycardia pacing (ATP) has gained an increasing importance in the treatment of ventricular arrhythmias, whether slow or fast. It reduces the number of unnecessary and inappropriate shocks and improves both patient's quality of life and device longevity. There is no clear indication regarding the type of ATP to be used, except for the treatment of fast ventricular tachycardias (188 bpm-250 bpm) where it has been shown a greater efficacy and safety of burst compared to ramp; 8 impulses in each sequence of ATP appears to be the best programming option in this setting. Beyond ATP use, excellent clinical results were obtained with programming standardization following these principles: extended detection time in ventricular fibrillation (VF) zone; supraventricular discrimination criteria up to 200 bpm; first shock in VF zone at the maximum energy in order to reduce the risk of multiple shocks. The MADIT-RIT trial and some observational registries have also recently demonstrated that programming with a widespread use of ATP, higher cut-off rates or delayed intervention reduces the number of inappropriate and unnecessary therapies and improves the survival of patients during mid-term follow-up.

  3. Pectoral nerves (PECS) and intercostal nerve block for cardiac resynchronization therapy device implantation.

    Science.gov (United States)

    Fujiwara, Atsushi; Komasawa, Nobuyasu; Minami, Toshiaki

    2014-01-01

    A 71-year-old man was scheduled to undergo cardiac resynchronization therapy device (CRTD) implantation. He was combined with severe chronic heart failure due to ischemic heart disease. NYHA class was 3 to 4 and electrocardiogram showed non-sustained ventricular. Ejection fraction was about 20% revealed by transthoracic echocardiogram. He was also on several anticoagulation medications. We planned to implant the device under the greater pectoral muscle. As general anesthesia was considered risky, monitored anesthesia care utilizing peripheral nerve block and slight sedation was scheduled. Pectoral nerves (PECS) block and intercostal block was performed under ultrasonography with ropivacaine. For sedation during the procedure, continuous infusion of dexmedetomidine without a loading dose was performed. The procedure lasted about 3 hours, but the patient showed no pain or restlessness. Combination of PECS block and intercostal block may provide effective analgesia for CRTD implantation.

  4. The Role of Implantable Cardioverter Defibrillators in Patients Bridged to Transplantation with a Continuous Flow Left Ventricular Assist Device: A Propensity Score Matched Analysis

    Science.gov (United States)

    Clerkin, Kevin J.; Topkara, Veli K.; Mancini, Donna M.; Yuzefpolskaya, Melana; Demmer, Ryan T.; Dizon, Jose M.; Takeda, Koji; Takayama, Hiroo; Naka, Yoshifumi; Colombo, Paolo C.; Garan, A. Reshad

    2016-01-01

    Background Implantable cardioverter defibrillators (ICD) provide a significant mortality benefit for appropriately selected patients with advanced heart failure. ICDs are associated with a mortality benefit when used in patients with a pulsatile left ventricular assist device (LVAD). However it is unclear whether patients with a continuous flow LVAD (CF-LVAD) derive the same benefit. This study sought to determine if the presence of an ICD provided a mortality benefit during CFLVAD support as a bridge to transplantation. Methods Patients were identified in the United Network for Organ Sharing (UNOS) registry that underwent LVAD implantation as bridge to transplantation from May 2004 and April 2014, with follow-up through June 2014. The primary outcome was freedom from death while on CF-LVAD support with adjustment for complications requiring UNOS listing status upgrade. Secondary endpoints included freedom from delisting while on CF-LVAD support and incidence of transplantation. Results 2,990 patients composed the study cohort and propensity score matching identified 1,012 patients with similar propensity scores. There was no difference in survival during device support between patients with and without an ICD (Hazard Ratio [HR] 1.20, 95% Confidence Interval [CI] 0.66-2.17, p=0.55). Adjusting for device complications requiring a UNOS listing status upgrade had minimal influence (HR 1.11, 95% CI 0.60-2.05, p=0.74). There was no increased risk of delisting due to being too sick for those with an ICD (HR 1.08, 95% CI 0.63-1.86, p=0.78). Likewise, the probability of transplantation was similar (HR 1.05, 95% CI 0.87-1.27, p=0.62). Conclusions Among patients bridged to transplantation with a CF-LVAD, the presence of an ICD did not reduce mortality. PMID:28089072

  5. The role of implantable cardioverter defibrillators in patients bridged to transplantation with a continuous-flow left ventricular assist device: A propensity score matched analysis.

    Science.gov (United States)

    Clerkin, Kevin J; Topkara, Veli K; Mancini, Donna M; Yuzefpolskaya, Melana; Demmer, Ryan T; Dizon, Jose M; Takeda, Koji; Takayama, Hiroo; Naka, Yoshifumi; Colombo, Paolo C; Garan, A Reshad

    2017-06-01

    Implantable cardioverter defibrillators (ICDs) provide a significant mortality benefit for appropriately selected patients with advanced heart failure. ICDs are associated with a mortality benefit when used in patients with a pulsatile left ventricular assist device (LVAD). It is unclear whether patients with a continuous-flow LVAD (CF-LVAD) derive the same benefit. We sought to determine if the presence of an ICD provided a mortality benefit during CF-LVAD support as a bridge to transplantation. Patients were identified in the United Network for Organ Sharing (UNOS) registry who underwent LVAD implantation as bridge to transplantation between May 2004 and April 2014, with follow-up through June 2014. Primary outcome was freedom from death while on CF-LVAD support with adjustment for complications requiring UNOS listing status upgrade. Secondary end-points included freedom from delisting while on CF-LVAD support and incidence of transplantation. The study cohort comprised 2,990 patients, and propensity score matching identified 1,012 patients with similar propensity scores. There was no difference in survival during device support between patients with and without an ICD (hazard ratio [HR] = 1.20; 95% confidence interval [CI], 0.66-2.17; p = 0.55). Adjusting for device complications requiring a UNOS listing status upgrade had minimal influence (HR = 1.11; 95% CI, 0.60-2.05; p = 0.74). There was no increased risk of delisting owing to being too sick for patients with an ICD (HR = 1.08; 95% CI, 0.63-1.86; p = 0.78). Likewise, the probability of transplantation was similar (HR = 1.05; 95% CI, 0.87-1.27; p = 0.62). Among patients bridged to transplantation with a CF-LVAD, the presence of an ICD did not reduce mortality. Copyright © 2017 International Society for Heart and Lung Transplantation. Published by Elsevier Inc. All rights reserved.

  6. Exploración estocástica de las superficies de energía potencial de dímeros cis-trans y trans-trans del ácido fórmico

    Directory of Open Access Journals (Sweden)

    Said F. Figueredo

    2014-01-01

    Full Text Available Potential energy surface (PES of cis-trans and trans-trans formic acid dimers were sampled using a stochastic method, and the geometries, energies, and vibrational frequencies were computed at B3LYP/6-311++G(3df,2p level of theory. The results show that molar free energy of dimerization deviated up to 108.4% when basis set superposition error (BSSE and zero-point energy (ZPE were not considered. For cis-trans dimers, C=O and O - H bond weakened, whereas C - O bonds strengthened due to dimerization. Also, trans-trans FA dimers did not show a trend regarding strengthening or weakening of the C=O, O - H and C - O bonds.

  7. Experimental study on the effect of an artificial cardiac valve on the left ventricular flow

    Science.gov (United States)

    Wang, JiangSheng; Gao, Qi; Wei, RunJie; Wang, JinJun

    2017-09-01

    The use of artificial valves to replace diseased human heart valves is currently the main solution to address the malfunctioning of these valves. However, the effect of artificial valves on the ventricular flow still needs to be understood in flow physics. The left ventricular flow downstream of a St. Jude Medical (SJM) bileaflet mechanical heart valve (BMHV), which is a widely implanted mechanical bileaflet valve, is investigated with time-resolved particle image velocimetry in the current work. A tilting-disk valve is installed on the aortic orifice to guarantee unidirectional flow. Several post-processing tools are applied to provide combined analyses of the physics involved in the ventricular flow. The triple jet pattern that is closely related to the characteristics of the bileaflet valve is discussed in detail from both Eulerian and Lagrangian views. The effects of large-scale vortices on the transportation of blood are revealed by the combined analysis of the tracking of Lagrangian coherent structures, the Eulerian monitoring of the shear stresses, and virtual dye visualization. It is found that the utilization of the SJM BMHV complicates the ventricular flow and could reduce the efficiency of blood transportation. In addition, the kinematics of the bileaflets is presented to explore the effects of flow structures on their motion. These combined analyses could elucidate the properties of SJM BMHV. Furthermore, they could provide new insights into the understanding of other complex blood flows.

  8. Long-term prospective outcomes after minimally invasive trans-iliac sacroiliac joint fusion using triangular titanium implants

    Directory of Open Access Journals (Sweden)

    Darr E

    2018-04-01

    Full Text Available Emily Darr,1 S Craig Meyer,2 Peter G Whang,3 Don Kovalsky,4 Clay Frank,5 Harry Lockstadt,6 Robert Limoni,7 Andy Redmond,8 Philip Ploska,9 Michael Y Oh,10 Daniel Cher,11 Abhineet Chowdhary12 1Orthopaedics and Physical Medicine, Medical University of South Carolina, Charleston, SC, USA; 2Columbia Orthopaedic Medical Group, Columbia, MO, USA; 3Department of Orthopedics, Yale University, New Haven, CT, USA; 4Orthopaedic Center of Southern Illinois, Mt. Vernon, IL, USA; 5Integrated Spine Care, Wauwatosa, WI, USA; 6Bluegrass Orthopedics, Lexington, KY, USA; 7Orthopedics & Sports Medicine, BayCare Clinic, Green Bay, WI, USA; 8Precision Spine Care, Tyler, TX, USA; 9OrthoSpine Solutions, Stockbridge, GA, USA; 10Allegheny General Hospital, Pittsburgh, PA, USA; 11SI-BONE, Inc., San Jose, CA, USA; 12Overlake Medical Center, Bellevue, WA, USA Background: Minimally invasive sacroiliac joint fusion (SIJF has become an increasingly accepted surgical option for chronic sacroiliac (SI joint dysfunction, a prevalent cause of unremitting low back/buttock pain. Objective: The objective of this study was to report clinical and functional outcomes of SIJF using triangular titanium implants (TTI in the treatment of chronic SI joint dysfunction due to degenerative sacroiliitis or sacroiliac joint (SIJ disruption at 3 years postoperatively. Methods: A total of 103 subjects with SIJ dysfunction at 12 centers were treated with TTI in two prospective clinical trials (NCT01640353 and NCT01681004 and enrolled in this long-term follow-up study (NCT02270203. Subjects were evaluated in study clinics at study start and again at 3, 4, and 5 years. Results: Mean (SD preoperative SIJ pain score was 81.5, and mean preoperative Oswestry Disability Index (ODI was 56.3. At 3 years, mean pain SIJ pain score decreased to 26.2 (a 55-point improvement from baseline, p<0.0001. At 3 years, mean ODI was 28.2 (a 28-point improvement from baseline, p<0.0001. In all, 82% of subjects were very

  9. Right Ventricular Endomyocardial Fibrosis Presenting With Ventricular Tachycardia And Apical Thrombus - An Interesting Presentation

    Directory of Open Access Journals (Sweden)

    Amitesh Aggarwal

    2009-11-01

    Full Text Available Endomyocardial fibrosis is a progressive disease of unknown origin affecting children and young adults. It involves inflow portion of right and/or left ventricle and apex. It may be associated with thrombus. Literature regarding right ventricular endomyocardial fibrosis with thrombus is scarce. Here we report a rare case of right ventricular endomyocardial fibrosis presenting as ventricular tachycardia and echocardiographic evidence of apical thrombus. Interestingly there was no pulmonary involvement or evidence of deep venous thrombosis. This case also underscores the importance of urgent echocardiography in diagnosis of obscure cases of ventricular tachycardia.

  10. [Long-term effects of hydroxychloroquine on metabolism of serum lipids and left ventricular structure and function in patients of systemic lupus erythematosus].

    Science.gov (United States)

    Meng, Juan; Lu, Yuewu; Dong, Xin; Liu, Hongyan

    2014-04-08

    To observe the long-term effects of hydroxychloroquine treatment on blood lipids and left ventricular function of systemic lupus erythematosus (SLE) patients. A total of 72 SLE patients were randomly divided into 2 groups of hydroxychloroquine treatment (n = 36) and non-hydroxychloroquine (n = 36). The serum level of lipids, left ventricular end-diastolic diameter (LVEDD), left ventricular end-systolic diameter (LVESD), interventricular septum thickness (IVST), left ventricular posterior wall thickness (LVPWT), fractional shortening rate (FS), left ventricular ejection fraction (LVEF) and E/A ratio were measured before, 6 month, 12 month and 2 years after treatment. After long-term use of hydroxychloroquine, there were statistically differences in the levels of total cholesterol (TC), triglyceride (TG), low-density lipoprotein (LDL) and high-density lipoprotein (HDL). And LVEDD, LVWPT and E/A were statistically different (P lipid metabolism and left ventricular function in SLE patients.

  11. The medical physics of ventricular assist devices

    International Nuclear Information System (INIS)

    Wood, Houston G; Throckmorton, Amy L; Untaroiu, Alexandrina; Song Xinwei

    2005-01-01

    Millions of patients, from infants to adults, are diagnosed with congestive heart failure each year all over the world. A limited number of donor hearts available for these patients results in a tremendous demand for alternative, supplemental circulatory support in the form of artificial heart pumps or ventricular assist devices (VADs). The development procedure for such a device requires careful consideration of biophysical factors, such as biocompatibility, haemolysis, thrombosis, implantability, physiologic control feasibility and pump performance. Conventional pump design equations based on Newton's law and computational fluid dynamics (CFD) are readily used for the initial design of VADs. In particular, CFD can be employed to predict the pressure-flow performance, hydraulic efficiencies, flow profile through the pump, stress levels and biophysical factors, such as possible blood cell damage. These computational flow simulations may involve comprehensive steady and transient flow analyses. The transient simulations involve time-varying boundary conditions and virtual modelling of the impeller rotation in the blood pumps. After prototype manufacture, laser flow measurements with sophisticated optics and mock circulatory flow loop testing assist with validation of pump design and identification of irregular flow patterns for optimization. Additionally, acute and chronic animal implants illustrate the blood pump's ability to support life physiologically. These extensive design techniques, coupled with fundamental principles of physics, ensure a reliable and effective VAD for thousands of heart failure patients each year

  12. Higher complication risk of totally implantable venous access port systems in patients with advanced cancer - a single institution retrospective analysis.

    Science.gov (United States)

    Chang, Yi-Fang; Lo, An-Chi; Tsai, Chung-Hsin; Lee, Pei-Yi; Sun, Shen; Chang, Te-Hsin; Chen, Chien-Chuan; Chang, Yuan-Shin; Chen, Jen-Ruei

    2013-02-01

    Totally implantable port systems are generally recommended for prolonged central venous access in diverse settings, but their risk of complications remains unclear for patients with advanced cancer. The aim of this study was to assess the risk of port system failure in patients with advanced cancer. We conducted a retrospective cohort study in a comprehensive cancer centre. A detailed chart review was conducted among 566 patients with 573 ports inserted during January-June, 2009 (average 345.3 catheter-days). Cox regression analysis was applied to evaluate factors during insertion and early maintenance that could lead to premature removal of the port systems due to infection or occlusion. Port system-related infection was significantly associated with receiving palliative care immediately after implantation (hazard ratio, HR = 7.3, 95% confidence interval, 95% CI = 1.2-46.0), after adjusting for probable confounders. Primary cancer site also impacted the occurrence of device-related infection. Receiving oncologic/palliative care (HR = 3.0, P = 0.064), advanced cancer stage (HR = 6.5, P = 0.077) and body surface area above 1.71 m(2) (HR = 3.4, P = 0.029) increased the risk of port system occlusion. Our study indicates that totally implantable port systems yield a higher risk of complications in terminally ill patients. Further investigation should be carefully conducted to compare outcomes of various central venous access devices in patients with advanced cancer and to develop preventive strategies against catheter failure.

  13. Electromagnetic interference of implantable cardiac devices from a shoulder massage machine.

    Science.gov (United States)

    Yoshida, Saeko; Fujiwara, Kousaku; Kohira, Satoshi; Hirose, Minoru

    2014-09-01

    Shoulder massage machines have two pads that are driven by solenoid coils to perform a per cussive massage on the shoulders. There have been concerns that such machines might create electromagnetic interference (EMI) in implantable cardiac devices because of the time-varying magnetic fields produced by the alternating current in the solenoid coils. The objective of this study was to investigate the potential EMI from one such shoulder massage machine on implantable cardiac devices. We measured the distribution profile of the magnetic field intensity around the massage machine. Furthermore, we performed an inhibition test and an asynchronous test on an implantable cardiac pacemaker using the standardized Irnich human body model. We examined the events on an implantable cardioverter-defibrillator (ICD) using a pacemaker programmer while the massage machine was in operation. The magnetic field distribution profile exhibited a peak intensity of 212 (A/m) in one of the solenoid coils. The maximal interference distance between the massage machine and the implantable cardiac pacemaker was 28 cm. Ventricular fibrillation was induced when the massage machine was brought near the electrode of the ICD and touched the Irnich human body model. It is necessary to provide a "don't use" warning on the box or the exterior of the massage machines or in the user manuals and to caution patients with implanted pacemakers about the dangers and appropriate usage of massage machines.

  14. Tomographic ventricular reconstruction using multiple view first-pass radionuclide angiography

    International Nuclear Information System (INIS)

    Lacy, J.L.; Ball, M.E.; Verani, M.S.; Wiles, H.; Roberts, R.

    1985-01-01

    In first-pass radionuclide angiography (FPRA) images of both left and right ventricles are uncontaminated by adjacent structures. Thus, the problem of tomographic reconstruction is vastly simplified compared to equilibrium blood pool imaging in which all structures are imaged simultaneously. Tomographic reconstruction from a limited number of views may thus be possible. A simple filtered interpolative back-projection reconstruction technique was employed. In this technique interpolation was used between sectional distributions at successive angles. Interpolations yielding 9 and 13 back projection angles of 22.5 0 and 15 0 were evaluated. Ventricular borders were obtained in each back-projected tomographic slice by location of the intensity level which provided correct total ventricular volume. Cast cross sections were quantitatively well represented by these borders. This ventricular border definition algorithm forms the basis for applications of the technique in animals and humans

  15. Heart rate variability density analysis (Dyx) for identification of appropriate implantable cardioverter defibrillator recipients among elderly patients with acute myocardial infarction and left ventricular systolic dysfunction

    DEFF Research Database (Denmark)

    Jørgensen, Rikke Mørch; Levitan, Jacob; Halevi, Zohar

    2015-01-01

    AIMS: Dyx is a new heart rate variability (HRV) density analysis specifically designed to identify patients at high risk for malignant ventricular arrhythmias. The aim of this study was to test if Dyx can improve risk stratification for malignant ventricular tachyarrhythmias and to test if the pr......AIMS: Dyx is a new heart rate variability (HRV) density analysis specifically designed to identify patients at high risk for malignant ventricular arrhythmias. The aim of this study was to test if Dyx can improve risk stratification for malignant ventricular tachyarrhythmias and to test...

  16. DEGRO/DGK guideline for radiotherapy in patients with cardiac implantable electronic devices

    International Nuclear Information System (INIS)

    Gauter-Fleckenstein, Benjamin; Steil, Volker; Wenz, Frederik; Israel, Carsten W.; Dorenkamp, Marc; Dunst, Juergen; Roser, Mattias; Schimpf, Rainer; Schaefer, Joerg; Hoeller, Ulrike

    2015-01-01

    An increasing number of patients undergoing radiotherapy (RT) have cardiac implantable electronic devices [CIEDs, cardiac pacemakers (PMs) and implanted cardioverters/defibrillators (ICDs)]. Ionizing radiation can cause latent and permanent damage to CIEDs, which may result in loss of function in patients with asystole or ventricular fibrillation. Reviewing the current literature, the interdisciplinary German guideline (DEGRO/DGK) was developed reflecting patient risk according to type of CIED, cardiac condition, and estimated radiation dose to the CIED. Planning for RT should consider the CIED specifications as well as patient-related characteristics (pacing-dependent, previous ventricular tachycardia/fibrillation). Antitachyarrhythmia therapy should be suspended in patients with ICDs, who should be under electrocardiographic monitoring with an external defibrillator on stand-by. The beam energy should be limited to 6 (to 10) MV CIEDs should never be located in the beam, and the cumulative scatter radiation dose should be limited to 2 Gy. Personnel must be able to respond adequately in the case of a cardiac emergency and initiate basic life support, while an emergency team capable of advanced life support should be available within 5 min. CIEDs need to be interrogated 1, 3, and 6 months after the last RT due to the risk of latent damage. (orig.) [de

  17. Right Ventricular Hemodynamics in Patients with Pulmonary Hypertension

    Science.gov (United States)

    Browning, James; Fenster, Brett; Hertzberg, Jean; Schroeder, Joyce

    2012-11-01

    Recent advances in cardiac magnetic resonance imaging (CMR) have allowed for characterization of blood flow in the right ventricle (RV), including calculation of vorticity and circulation, and qualitative visual assessment of coherent flow patterns. In this study, we investigate qualitative and quantitative differences in right ventricular hemodynamics between subjects with pulmonary hypertension (PH) and normal controls. Fifteen (15) PH subjects and 10 age-matched controls underwent same day 3D time resolved CMR and echocardiography. Echocardiography was used to determine right ventricular diastolic function as well as pulmonary artery systolic pressure (PASP). Velocity vectors, vorticity vectors, and streamlines in the RV were visualized in Paraview and total RV Early (E) and Atrial (A) wave diastolic vorticity was quantified. Visualizations of blood flow in the RV are presented for PH and normal subjects. The hypothesis that PH subjects exhibit different RV vorticity levels than normals during diastole is tested and the relationship between RV vorticity and PASP is explored. The mechanics of RV vortex formation are discussed within the context of pulmonary arterial pressure and right ventricular diastolic function coincident with PH.

  18. Trends in cochlear implants.

    Science.gov (United States)

    Zeng, Fan-Gang

    2004-01-01

    More than 60,000 people worldwide use cochlear implants as a means to restore functional hearing. Although individual performance variability is still high, an average implant user can talk on the phone in a quiet environment. Cochlear-implant research has also matured as a field, as evidenced by the exponential growth in both the patient population and scientific publication. The present report examines current issues related to audiologic, clinical, engineering, anatomic, and physiologic aspects of cochlear implants, focusing on their psychophysical, speech, music, and cognitive performance. This report also forecasts clinical and research trends related to presurgical evaluation, fitting protocols, signal processing, and postsurgical rehabilitation in cochlear implants. Finally, a future landscape in amplification is presented that requires a unique, yet complementary, contribution from hearing aids, middle ear implants, and cochlear implants to achieve a total solution to the entire spectrum of hearing loss treatment and management.

  19. The effect of a single infusion of zoledronic acid on early implant migration in total hip arthroplasty. A randomized, double-blind, controlled trial.

    Science.gov (United States)

    Friedl, Gerald; Radl, Roman; Stihsen, Christoph; Rehak, Peter; Aigner, Reingard; Windhager, Reinhard

    2009-02-01

    Aseptic loosening is the most frequent cause of implant failure in total hip arthroplasty. While a direct link between aseptic loosening and periprosthetic bone loss remains elusive, there is plentiful evidence for a close association with early implant migration. The present trial was primarily designed to evaluate whether a single infusion of 4 mg of zoledronic acid prevented early implant migration in patients with osteonecrosis of the femoral head. Fifty patients were consecutively enrolled to receive either zoledronic acid or saline solution after cementless total hip arthroplasty. Radiographs, biochemical parameters of bone turnover, and the Harris hip-rating score were determined preoperatively and at each follow-up examination at seven weeks, six months, one year, and yearly thereafter. The median follow-up period was 2.8 years. We found a significant subsidence of the stem of up to a mean (and standard deviation) of -1.2 +/- 0.6 mm at two years within the control group, and the cups had a mean medialization of 0.6 +/- 1.0 mm and a mean cranialization of 0.6 +/- 0.8 mm (p < 0.001). Treatment with zoledronic acid effectively minimized the migration of the cups in both the transverse and the vertical direction (mean, 0.15 +/- 0.6 mm and 0.06 +/- 0.6 mm, respectively; p < 0.05), while only a trend to decreased subsidence of the stem was detected. Finally, the Harris hip score rapidly increased over time in both treatment groups, although this increase was significantly more pronounced in the zoledronate-treated group than in the control group (analysis of variance, p = 0.008). A single infusion of zoledronic acid shows promise in improving initial fixation of a cementless implant, which may improve the clinical outcome of total hip arthroplasty in patients with osteonecrosis of the femoral head.

  20. Comparison of valvar and right ventricular function following transcatheter and surgical pulmonary valve replacement.

    Science.gov (United States)

    Li, Wendy F; Pollard, Heidi; Karimi, Mohsen; Asnes, Jeremy D; Hellenbrand, William E; Shabanova, Veronika; Weismann, Constance G

    2018-01-01

    Trans-catheter (TC) pulmonary valve replacement (PVR) has become common practice for patients with right ventricular outflow tract obstruction (RVOTO) and/or pulmonic insufficiency (PI). Our aim was to compare PVR and right ventricular (RV) function of patients who received TC vs surgical PVR. Retrospective review of echocardiograms obtained at three time points: before, immediately after PVR, and most recent. Sixty-two patients (median age 19 years, median follow-up 25 months) following TC (N = 32) or surgical (N = 30) PVR at Yale-New Haven Hospital were included. Pulmonary valve and right ventricular function before, immediately after, and most recently after PVR. At baseline, the TC group had predominant RVOTO (74% vs 10%, P function was good throughout. At last follow-up, the TC group had preserved valve function, but the surgical group did not (moderate RVOTO: 6% vs 41%, P mild PI: 0% vs 24%, P = .003). Patients younger than 17 years at surgical PVR had the highest risk of developing PVR dysfunction, while PVR function in follow-up was similar in adults. Looking at RV size and function, both groups had a decline in RV size following PVR. However, while RV function remained stable in the TC group, there was a transient postoperative decline in the surgical group. TC PVR in patients age function in follow-up compared to surgical valves. There was a transient decline in RV function following surgical but not TC PVR. TC PVR should therefore be the first choice in children who are considered for PVR, whenever possible. © 2017 Wiley Periodicals, Inc.

  1. Chronic multisite brain recordings from a totally implantable bidirectional neural interface: experience in 5 patients with Parkinson's disease.

    Science.gov (United States)

    Swann, Nicole C; de Hemptinne, Coralie; Miocinovic, Svjetlana; Qasim, Salman; Ostrem, Jill L; Galifianakis, Nicholas B; Luciano, Marta San; Wang, Sarah S; Ziman, Nathan; Taylor, Robin; Starr, Philip A

    2018-02-01

    OBJECTIVE Dysfunction of distributed neural networks underlies many brain disorders. The development of neuromodulation therapies depends on a better understanding of these networks. Invasive human brain recordings have a favorable temporal and spatial resolution for the analysis of network phenomena but have generally been limited to acute intraoperative recording or short-term recording through temporarily externalized leads. Here, the authors describe their initial experience with an investigational, first-generation, totally implantable, bidirectional neural interface that allows both continuous therapeutic stimulation and recording of field potentials at multiple sites in a neural network. METHODS Under a physician-sponsored US Food and Drug Administration investigational device exemption, 5 patients with Parkinson's disease were implanted with the Activa PC+S system (Medtronic Inc.). The device was attached to a quadripolar lead placed in the subdural space over motor cortex, for electrocorticography potential recordings, and to a quadripolar lead in the subthalamic nucleus (STN), for both therapeutic stimulation and recording of local field potentials. Recordings from the brain of each patient were performed at multiple time points over a 1-year period. RESULTS There were no serious surgical complications or interruptions in deep brain stimulation therapy. Signals in both the cortex and the STN were relatively stable over time, despite a gradual increase in electrode impedance. Canonical movement-related changes in specific frequency bands in the motor cortex were identified in most but not all recordings. CONCLUSIONS The acquisition of chronic multisite field potentials in humans is feasible. The device performance characteristics described here may inform the design of the next generation of totally implantable neural interfaces. This research tool provides a platform for translating discoveries in brain network dynamics to improved neurostimulation

  2. Radiofrequency ablation of fast ventricular tachycardia causing an ICD storm in an infant with hypertrophic cardiomyopathy.

    Science.gov (United States)

    Ergul, Yakup; Ozyilmaz, Isa; Bilici, Meki; Ozturk, Erkut; Haydin, Sertaç; Guzeltas, Alper

    2018-04-01

    An implantable cardioverter defibrillator (ICD) storm involves very frequent arrhythmia episodes and ICD shocks, and it is associated with poor short-term and long-term prognosis. Radiofrequency catheter ablation can be used as an effective rescue treatment for patients with an ICD storm. To our knowledge, this is the first report of an infant with hypertrophic cardiomyopathy presenting with an ICD storm and undergoing successful radiofrequency catheter ablation salvage treatment for the fast left posterior fascicular ventricular tachycardia. © 2017 Wiley Periodicals, Inc.

  3. Cardiac magnetic resonance imaging for evaluation of non-compaction cardiomyopathy in patients with or without left ventricular systolic dysfunction

    International Nuclear Information System (INIS)

    Deviggiano, A.; Deschle, H.; Lewkowicz, J.M.; Tajer, C.D.; Carrascosa, P.; Capunay, C.; Vallejos, J.; Stewart Harris, A.

    2011-01-01

    Background: Non-compaction cardiomyopathy (NCC) is a genetic disorder characterized by deep trabeculations in the ventricular wall, which define recesses communicating with the main ventricular chamber. The prevalence of NCC is greater in symptomatic populations with left ventricular dysfunction; yet, it may also be detected in asymptomatic patients with normal left ventricular function using novel diagnostic tools. However, this condition is under-diagnosed due to a low index of clinical suspicion and to the use of echocardiography classifications based on different diagnostic criteria. The use of cardiac magnetic resonance imaging (CMRI) has established two diagnostic criteria that clearly recognize this disease. Objective: To evaluate the clinical and morphological characteristics of patients with NCC with and without systolic dysfunction undergoing cardiac magnetic resonance imaging (CMRI). Material and Methods: A total of 20 patients with NCC were retrospectively included. The following parameters were determined: left ventricular end-diastolic volume (LVEDV), left ventricular end-systolic volume (LVESV); left ventricular end-diastolic diameter (LVEDD); left ventricular end-systolic diameter (LVESD); cardiac mass and left ventricular trabeculations. The distribution of NC myocardium was evaluated according to the model of 17 myocardial segments. Results: Mean myocardial thickness was 13.1 ± 3.3 mm and 3.6 ± 0.6 mm in NC versus normal myocardium, respectively. Patients with left ventricular dysfunction presented increased LVEDD, LVEDV, total cardiac mass, and LV non-compaction and trabeculations. We found a positive correlation and a linear relationship between LVEDD and TLVM (g/m 2 ): r=0.76; r 2 =0.59; p [es

  4. Electromagnetic interference from welding and motors on implantable cardioverter-defibrillators as tested in the electrically hostile work site.

    Science.gov (United States)

    Fetter, J G; Benditt, D G; Stanton, M S

    1996-08-01

    This study was designed to determine the susceptibility of an implanted cardioverter-defibrillator to electromagnetic interference in an electrically hostile work site environment, with the ultimate goal of allowing the patient to return to work. Normal operation of an implanted cardioverter-defibrillator depends on reliable sensing of the heart's electrical activity. Consequently, there is concern that external electromagnetic interference from external sources in the work place, especially welding equipment or motor-generator systems, may be sensed and produce inappropriate shocks or abnormal reed switch operation, temporarily suspending detection of ventricular tachycardia or ventricular fibrillation. The effects of electromagnetic interference on the operation of one type of implantable cardioverter-defibrillator (Medtronic models 7217 and 7219) was measured by using internal event counter monitoring in 10 patients operating arc welders at up to 900 A or working near 200-hp motors and 1 patient close to a locomotive starter drawing up to 400 A. The electromagnetic interference produced two sources of potential interference on the sensing circuit or reed switch operation, respectively: 1) electrical fields with measured frequencies up to 50 MHz produced by the high currents during welding electrode activation, and 2) magnetic fields produced by the current in the welding electrode and cable. The defibrillator sensitivity was programmed to the highest (most sensitive) value: 0.15 mV (model 7219) or 0.3 mV (model 7217). The ventricular tachycardia and ventricular fibrillation therapies were temporarily turned off but the detection circuits left on. None of the implanted defibrillators tested were affected by oversensing of the electric field as verified by telemetry from the detection circuits. The magnetic field from 225-A welding current produced a flux density of 1.2 G; this density was not adequate to close the reed switch, which requires approximately 10 G

  5. Implantable Cardioverter-Defibrillators in Patients With a Continuous-Flow Left Ventricular Assist Device: An Analysis of the INTERMACS Registry.

    Science.gov (United States)

    Clerkin, Kevin J; Topkara, Veli K; Demmer, Ryan T; Dizon, Jose M; Yuzefpolskaya, Melana; Fried, Justin A; Mai, Xingchen; Mancini, Donna M; Takeda, Koji; Takayama, Hiroo; Naka, Yoshifumi; Colombo, Paolo C; Garan, A Reshad

    2017-12-01

    This study sought to determine if the presence of implantable cardioverter-defibrillators (ICD) provided a mortality benefit during continuous-flow left ventricular assist device (LVAD) support. An ICD decreases mortality in selected patients with advanced heart failure and have been associated with reduced mortality in patients with pulsatile LVAD. However, it is unclear whether that benefit extends to patients with a contemporary continuous-flow LVAD. Propensity score matching was used to generate a cohort of patients with similar baseline characteristics. The primary outcome was freedom from death during LVAD support. Secondary endpoints included freedom from unexpected death, likelihood of transplantation and recovery, and adverse events. Among 16,384 eligible patients in the Interagency Registry for Mechanically Assisted Circulatory Support registry, 2,209 patients with an ICD and 2,209 patients without one had similar propensity scores and were included. The presence of an ICD was associated with an increased mortality risk (hazard ratio: 1.20; 95% confidence interval [CI]: 1.04 to 1.39; p = 0.013) and an increased risk of unexpected death during device support (HR: 1.33; 95% CI: 1.03 to 1.71; p = 0.03). Patients with an ICD were more likely to undergo transplantation (HR: 1.16; 95% CI: 0.99 to 1.35; p = 0.06) and less likely to have LVAD explant for recovery (HR: 0.53, 95% CI: 0.29 to 0.98; p = 0.04). Patients with an ICD had a higher rate of treated ventricular arrhythmias (rate ratio: 1.27; 95% CI: 1.10 to 1.48; p = 0.001) and rehospitalization (rate ratio: 1.08; 95% CI: 1.04 to 1.12; p < 0.0001), but rates of hemorrhagic stroke were similar (rate ratio: 1.01; 95% CI: 0.81 to 1.26; p = 0.98). Among patients with a continuous flow LVAD, the presence of an ICD was not associated with reduced mortality. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  6. Cardiothoracic ratio for prediction of left ventricular dilation: a systematic review and pooled analysis.

    Science.gov (United States)

    Loomba, Rohit S; Shah, Parinda H; Nijhawan, Karan; Aggarwal, Saurabh; Arora, Rohit

    2015-03-01

    Increased cardiothoracic ratio noted on chest radiographs often prompts concern and further evaluation with additional imaging. This study pools available data assessing the utility of cardiothoracic ratio in predicting left ventricular dilation. A systematic review of the literature was conducted to identify studies comparing cardiothoracic ratio by chest x-ray to left ventricular dilation by echocardiography. Electronic databases were used to identify studies which were then assessed for quality and bias, with those with adequate quality and minimal bias ultimately being included in the pooled analysis. The pooled data were used to determine the sensitivity, specificity, positive predictive value and negative predictive value of cardiomegaly in predicting left ventricular dilation. A total of six studies consisting of 466 patients were included in this analysis. Cardiothoracic ratio had 83.3% sensitivity, 45.4% specificity, 43.5% positive predictive value and 82.7% negative predictive value. When a secondary analysis was conducted with a pediatric study excluded, a total of five studies consisting of 371 patients were included. Cardiothoracic ratio had 86.2% sensitivity, 25.2% specificity, 42.5% positive predictive value and 74.0% negative predictive value. Cardiothoracic ratio as determined by chest radiograph is sensitive but not specific for identifying left ventricular dilation. Cardiothoracic ratio also has a strong negative predictive value for identifying left ventricular dilation.

  7. Right Ventricular Outflow Tract Tachycardia with Structural Abnormalities of the Right Ventricle and Left Ventricular Diverticulum

    Directory of Open Access Journals (Sweden)

    Bortolo Martini

    2015-01-01

    Full Text Available A 43-year-old woman presented to the emergency room with a sustained ventricular tachycardia (VT. ECG showed a QRS in left bundle branch block morphology with inferior axis. Echocardiography, ventricular angiography, and cardiac magnetic resonance imaging (CMRI revealed a normal right ventricle and a left ventricular diverticulum. Electrophysiology studies with epicardial voltage mapping identified a large fibrotic area in the inferolateral layer of the right ventricular wall and a small area of fibrotic tissue at the anterior right ventricular outflow tract. VT ablation was successfully performed with combined epicardial and endocardial approaches.

  8. Prognostic incremental role of right ventricular function in acute decompensation of advanced chronic heart failure.

    Science.gov (United States)

    Frea, Simone; Pidello, Stefano; Bovolo, Virginia; Iacovino, Cristina; Franco, Erica; Pinneri, Francesco; Galluzzo, Alessandro; Volpe, Alessandra; Visconti, Massimiliano; Peirone, Andrea; Morello, Mara; Bergerone, Serena; Gaita, Fiorenzo

    2016-05-01

    The purpose of this study was to evaluate the additional prognostic value of echocardiography in acute decompensation of advanced chronic heart failure (CHF), focusing on right ventricular (RV) dysfunction and its interaction with loading conditions. Few data are available on the prognostic role of echocardiography in acute HF and on the significance of pulmonary hypertension in patients with severe RV failure. A total of 265 NYHA IV patients admitted for acute decompensation of advanced CHF (EF 22 ± 7%, systolic blood pressure 107 ± 20 mmHg) were prospectively enrolled. Fifty-nine patients met the primary composite endpoint of cardiac death, urgent heart transplantation, and urgent mechanical circulatory support implantation at 90 days. Pulmonary hypertension failed to predict events, while patients with a low transtricuspid systolic gradient (TR gradient statistic from 0.59 to 0.73 (P advanced CHF, pulmonary hypertension failed to predict events. The in-hospital and short-term prognosis can be better predicted by eRAP and RVCPI. © 2016 The Authors. European Journal of Heart Failure © 2016 European Society of Cardiology.

  9. Cis By Trans

    OpenAIRE

    Rodovalho,Amara Moira

    2017-01-01

    Cis, trans: above all, metaphors. Cisjordan, region skirting the Jordan River. Cisplatin, Uruguay’s ancient name, region occupying one of the banks of the Prata River. Trans- Amazonian, that which crosses the Amazon; transatlantic, that which crosses the Atlantic. Cisalpine, transalpine. The geometric isomerism of Organic Chemistry, where “cis” are atoms that, when molecules are divided in half, remain on the same side, and “trans” those remaining on opposite sides. Ev...

  10. Crystallinity and the effect of ionizing radiation in polyethylene. V. Distribution of trans-vinylene and trans, trans conjugated double bonds in linear polyethylene

    International Nuclear Information System (INIS)

    Patel, G.N.

    1975-01-01

    Freeze-dried chain folded single crystals and the single crystals without amorphous surface layers (crystalline cores) of different thicknesses of linear polyethylene were irradiated with 60 Co γ-rays up to 600 Mrad. Concentration of trans-vinylene double bonds and conjugated diene produced during irradiation of the crystals was measured by infrared. Concentrations of trans-vinylene and of the conjugated diene were independent of thickness of crystalline core which suggest that the double bonds were randomly distributed in the crystalline parts of the crystals. Concentrations of trans-vinylene and of conjugated double bonds were lower in chain-folded crystals than in the crystalline cores and this suggests that the folds (amorphous surface layers) are less preferential sites for formation of the double bonds. The zero-order growth and first-order decay kinetics of trans-vinylene double bonds was studied by the equation derived by Dole et al. The equation is strictly obeyed up to 300 Mrad and the results then deviate. Since there is the decay of trans-vinylene double bonds and though there are no crosslinks in the crystalline cores, it has been suggested that the decay of the double bond does not result in the crosslinks

  11. PUTAS Y TRANS. ¿ESTÁN LAS MUJERES TRANS EN LAS NARRATIVAS SOBRE LA PROSTITUCIÓN?

    Directory of Open Access Journals (Sweden)

    Liza García Reyes

    2015-06-01

    Full Text Available Este artículo evidencia los principales resultados de la investigación cualitativa titulada: Putas y trans. Narrativas sobre mujeres trans en España –desarrollada en 2010–, la cual estudió su presencia en textos académicos sobre prostitución en España, producidos entre los años 2000-2009. El análisis de contenido de 34 narrativas evidenció que las referencias a mujeres trans resulta escasa en ellas, aun siendo ellas quienes tienen mayor presencia en la prostitución, en proporción con las mujeres biológicas. Solo nueve textos mencionan la experiencia trans al interior de la prostitución y, entre estos, el asunto solo aparece asertivamente descrito cuando son las propias mujeres trans quienes escriben. AbstractThis paper shows the results of a qualitative research entitled: Hookers and Trans Women: Narratives about trans women in Spain. This study was developed in 2010 and it is based on presence of trans women in the academic texts of prostitution in Spain produced between 2000 and 2009. The content analysis of thirty four narratives showed that the references to in transsexual women in these texts were few, although they have more presence into prostitution, in relation to the biological women. Only nine texts show an experience of prostitution and among these, transexperience only is described assertively when transsexual women write the texts themselves.

  12. Dual chamber pacemaker implants - a new opportunity in Pakistan for children with congenital and acquired complete heart block

    International Nuclear Information System (INIS)

    Ashfaq, A.; Khan, M.A.; Atiq, M.

    2011-01-01

    Implantation of cardiac pacemakers has been practiced for at least five decades with continuous developments of the hardware. The invention of dual chamber pacemakers has initiated a debate concerning its superiority over single chamber ventricular pacemakers. Throughout the world, surgeons have been using dual chambered permanent pacemakers with successful follow ups. However, Pakistan has not yet taken the advantage of such pacemaker devices till now. We report three cases that underwent a dual chamber permanent pacemaker implantation for the first time in children less than 8 kg with successful follow ups. (author)

  13. Current State and Future Perspectives of Energy Sources for Totally Implantable Cardiac Devices.

    Science.gov (United States)

    Bleszynski, Peter A; Luc, Jessica G Y; Schade, Peter; PhilLips, Steven J; Tchantchaleishvili, Vakhtang

    There is a large population of patients with end-stage congestive heart failure who cannot be treated by means of conventional cardiac surgery, cardiac transplantation, or chronic catecholamine infusions. Implantable cardiac devices, many designated as destination therapy, have revolutionized patient care and outcomes, although infection and complications related to external power sources or routine battery exchange remain a substantial risk. Complications from repeat battery replacement, power failure, and infections ultimately endanger the original objectives of implantable biomedical device therapy - eliminating the intended patient autonomy, affecting patient quality of life and survival. We sought to review the limitations of current cardiac biomedical device energy sources and discuss the current state and trends of future potential energy sources in pursuit of a lifelong fully implantable biomedical device.

  14. Right ventricular pressure response to exercise in adults with isolated ventricular septal defect closed in early childhood.

    Science.gov (United States)

    Moller, Thomas; Lindberg, Harald; Lund, May Brit; Holmstrom, Henrik; Dohlen, Gaute; Thaulow, Erik

    2018-06-01

    We previously demonstrated an abnormally high right ventricular systolic pressure response to exercise in 50% of adolescents operated on for isolated ventricular septal defect. The present study investigated the prevalence of abnormal right ventricular systolic pressure response in 20 adult (age 30-45 years) patients who underwent surgery for early ventricular septal defect closure and its association with impaired ventricular function, pulmonary function, or exercise capacity. The patients underwent cardiopulmonary tests, including exercise stress echocardiography. Five of 19 patients (26%) presented an abnormal right ventricular systolic pressure response to exercise ⩾ 52 mmHg. Right ventricular systolic function was mixed, with normal tricuspid annular plane systolic excursion and fractional area change, but abnormal tricuspid annular systolic motion velocity (median 6.7 cm/second) and isovolumetric acceleration (median 0.8 m/second2). Left ventricular systolic and diastolic function was normal at rest as measured by the peak systolic velocity of the lateral wall and isovolumic acceleration, early diastolic velocity, and ratio of early diastolic flow to tissue velocity, except for ejection fraction (median 53%). The myocardial performance index was abnormal for both the left and right ventricle. Peak oxygen uptake was normal (mean z score -0.4, 95% CI -2.8-0.3). There was no association between an abnormal right ventricular systolic pressure response during exercise and right or left ventricular function, pulmonary function, or exercise capacity. Abnormal right ventricular pressure response is not more frequent in adult patients compared with adolescents. This does not support the theory of progressive pulmonary vascular disease following closure of left-to-right shunts.

  15. Patient with a total artificial heart maintained on outpatient dialysis while listed for combined organ transplant, a single center experience.

    Science.gov (United States)

    Hanna, Ramy M; Hasnain, Huma; Kamgar, Mohammad; Hanna, Mina; Minasian, Raffi; Wilson, James

    2017-10-01

    Advanced mechanical circulatory support is increasingly being used with more sophisticated devices that can deliver pulsatile rather than continuous flow. These devices are more portable as well, allowing patients to await cardiac transplantation in an outpatient setting. It is known that patients with renal failure are at increased risk for developing worsening acute kidney injury during implantation of a ventricular assist device (VAD) or more advanced modalities like a total artificial heart (TAH). Dealing with patients who have an implanted TAH who develop renal failure has been a challenge with the majority of such patients having to await a combined cardiac and renal transplant prior to transition to outpatient care. Protocols do exist for VAD implanted patients to be transitioned to outpatient dialysis care, but there are no reported cases of TAH patients with end stage renal disease (ESRD) being successfully transitioned to outpatient dialysis care. In this report, we identify a patient with a TAH and ESRD transitioned successfully to outpatient hemodialysis and maintained for more than 2 years, though he did not survive to transplant. It is hoped that this report will raise awareness of this possibility, and assist in the development of protocols for similar patients to be successfully transitioned to outpatient dialysis care. © 2017 International Society for Hemodialysis.

  16. Long-Term Primary Patency Rate After Nitinol Self-Expandable Stents Implantation in Long, Totally Occluded Femoropopliteal (TASC II C & D) Lesions.

    Science.gov (United States)

    Elmahdy, Mahmoud Farouk; Buonamici, Piergiovanni; Trapani, Maurizio; Valenti, Renato; Migliorini, Angela; Parodi, Guido; Antoniucci, David

    2017-06-01

    Endovascular therapy for long femoropopliteal lesions using percutaneous transluminal balloon angioplasty or first-generation of peripheral stents has been associated with unacceptable one-year restenosis rates. However, with recent advances in equipment and techniques, a better primary patency rate is expected. This study was conducted to detect the long-term primary patency rate of nitinol self-expandable stents implanted in long, totally occluded femoropopliteal lesions TransAtlantic Inter-Society Census (TASC II type C & D), and determine the predictors of reocclusion or restenosis in the stented segments. The demographics, clinical, anatomical, and procedural data of 213 patients with 240 de novo totally occluded femoropopliteal (TASC II type C & D) lesions treated with nitinol self-expandable stents were retrospectively analysed. Of these limbs, 159 (66.2%) presented with intermittent claudication, while 81 (33.8%) presented with critical limb ischaemia. The mean-time of follow-up was 36±22.6 months, (range: 6.3-106.2 months). Outcomes evaluated were, primary patency rate and predictors of reocclusion or restenosis in the stented segments. The mean age of the patients was 70.9±9.3 years, with male gender 66.2%. Mean pre-procedural ABI was 0.45±0.53. One-hundred-and-seventy-five (73%) lesions were TASC II type C, while 65 (27%) were type D lesions. The mean length of the lesions was 17.9±11.3mm. Procedure related complications occurred in 10 (4.1%) limbs. There was no periprocedural mortality. Reocclusion and restenosis were detected during follow-up in 45 and 30 limbs respectively, and all were re-treated by endovascular approach. None of the patients required major amputation. Primary patency rates were 81.4±1.1%, 77.7±1.9% and 74.4±2.8% at 12, 24, and 36 months respectively. Male gender, severe calcification, and TASC II D lesion were independent predictors for reocclusion, while predictors of restenosis were DM, smoking and TASC II D lesions

  17. [Bentall operation combined with total arch replacement and stented elephant trunk implantation for serious Debakey I aortic dissecting aneurysm].

    Science.gov (United States)

    Gu, Tian-Xiang; Wang, Chun; Zhang, Yu-Hai

    2008-12-01

    To summarize the clinical experience of Bentall operation combined with total arch replacement and stented elephant trunk implantation for serious Debakey I aortic dissecting aneurysm. Twelve patients with serious Debakey I aortic dissecting aneurysm underwent surgical treatment from January 2005 to December 2007. There were 10 male and 2 female with the mean age of (40.1 +/- 9.5) years old. There were acute aortic dissection in 9 cases, chronic aortic dissection in 3 cases. The inner diameter of aorta was (5.3 +/- 1.8) cm. There were Marfan syndrome in 4 cases, aortic regurgitation in all cases, severely persistent chest pain in 9 cases, acute left heart failure in 8 cases, and cardiac tamponade in 4 cases. Bentall operations combined with total arch replacement and stented elephant trunk implantation were performed by using deep hypothermic circulatory arrest and antegrade selective cerebral perfusion in all cases. Urgent surgery underwent in 9 cases. The mean interval between the onset of aortic dissection and the accomplishment of surgery was (41.0 +/- 15.9) hours. Cardiopulmonary bypass time was (191 +/- 26) min, average cross clamp time was (134 +/- 31) min, and average deep hypothermic circulatory arrest time was (50.0 +/- 14.5) min. One patient died in hospital. The time stayed in ICU was 3 to 27 d. Mental disorder in 6 cases, hemi-paralysis in 1 case, amputation in 1 case, hemorrhage of anastomosis in 1 case, hemorrhage of alimentary tract in 1 case, and pleural effusion in 4 cases were recorded. Eleven cases were followed-up for 8 weeks to 36 months. There were no bending of the stents and no obstruction in the vascular prosthesis.No re-operation was needed. One case died 6 months postoperatively. Bentall operation combined with total arch replacement and stented elephant trunk implantation is safe and effective for serious Debakey I aortic dissecting aneurysm, while good organs protection and consummate cardiopulmonary bypass were taken.

  18. Four cases of right ventricular dysplasia

    International Nuclear Information System (INIS)

    Takamura, Ichiro; Ando, Joji; Miyamoto, Atsushi; Kobayashi, Takeshi; Sakamoto, Sanya; Yasuda, Hisakazu

    1985-01-01

    Finding of 81 Kr right ventriculography and 201 Tl myocardial perfusion imaging in 4 patients with right ventricular dysplasia (RVD) were compared with those in 28 patients with dilated cardiomyopathy. Remarkably dilated right ventricle was detected on 201 Tl myocardial perfusion imaging in the RVD group. In a patient with RVD who died suddenly, perfusion defect of the left ventricular myocardium, a decreased right ventricular ejection fraction, and an increased right ventricular end diastolic volume were seen. Perfusion defect of the left ventricular myocardium was seen in 10 of the 28 patients with dilated cardiomyopathy, 4 of whom died suddenly. In these 4 patients, a decreased left ventricular ejection fraction and an increased right ventricular end diastolic volume were seen. These findings obtained by the radionuclide techniques suggested that there are differences in cardiac dysfunction of the both ventricles between the groups with RVD and dilated cardiomyopathy. (Namekawa, K.)

  19. Hemodynamic instability after pulmonary veins isolation in a patient with dual chamber pacemaker: The phantom injury of the ventricular lead.

    Science.gov (United States)

    Kiuchi, Márcio Galindo; Lobato, Guilherme Miglioli; Chen, Shaojie

    2017-06-01

    The standard treatment of sinus node dysfunction (SND) is the pacemaker implantation, and the ideal methodology for the management of atrial fibrillation (AF) is rhythm control, but this is sometimes very hard to accomplish. For such actions, complete isolation of all pulmonary veins (PVI) is currently widely accepted as the best endpoint. In this case, we report a female patient, 81 years old, with controlled hypertension, without coronary artery disease, bearer of bilateral knee replacement, and dual chamber pacemaker implanted 1.5 years ago owing to sinus node disease, presenting the following symptoms: presyncope episodes associated with sustained irregular palpitation tachycardia. The evaluation of the pacemaker-recorded episodes of atrial fibrillation, the echocardiogram-presented normal systolic function and measurements, as well as the resting myocardial scintigraphy and with drug use did not demonstrate ischemia and/or fibrosis. The patient was in use of valsartan 320 mg daily, amlodipine 10 mg daily, sotalol hydrochloride 120 mg 2 times daily, and dabigatran 110 mg 2 times daily. At the end of the PVI, the patient presented hemodynamic instability, with a decrease in heart rate to 30 bpm and invasive arterial blood pressure to 60/30 mmHg. The pericardial puncture was quickly carried out with the possibility of cardiac tamponade as the first hypothesis, but no pericardial effusion was found. Next, we detected acute capture loss from the ventricular pacemaker lead, unvarying with high voltage and pulse width, even with stable impedance, sense and keeping the same position visualized by fluoroscopy. And there was soon afterwards induction of sustained ventricular tachycardia degenerating to spontaneous ventricular fibrillation. Electrical cardioversion-defibrillation was performed with 200J, and the sinus rhythm was reestablished, but there was a dead short, and the pacemaker generator was burned and disabled. So, we can speculate that

  20. After runaway: The trans-Hill stage of planetesimal growth

    International Nuclear Information System (INIS)

    Lithwick, Yoram

    2014-01-01

    When planetesimals begin to grow by coagulation, they first enter an epoch of runaway, during which the biggest bodies grow faster than all the others. The questions of how runaway ends and what comes next have not been answered satisfactorily. We show that runaway is followed by a new stage—the 'trans-Hill stage'—that commences when the bodies that dominate viscous stirring ('big bodies') become trans-Hill, i.e., when their Hill velocity matches the random speed of the small bodies they accrete. Subsequently, the small bodies' random speed grows in lockstep with the big bodies' sizes, such that the system remains in the trans-Hill state. Trans-Hill growth is crucial for determining the efficiency of growing big bodies, as well as their growth timescale and size spectrum. Trans-Hill growth has two sub-stages. In the earlier one, which occurs while the stirring bodies remain sufficiently small, the evolution is collisionless, i.e., collisional cooling among all bodies is irrelevant. The efficiency of forming big bodies in this collisionless sub-stage is very low, ∼10α << 1, where α ∼ 0.005(a/AU) –1 is the ratio between the physical size of a body and its Hill radius. Furthermore, the size spectrum is flat (equal mass per size decade, i.e., q = 4). This collisionless trans-Hill solution explains results from previous coagulation simulations for both the Kuiper Belt and the asteroid belt. The second trans-Hill sub-stage commences once the stirring bodies grow big enough (>α –1 × the size of the accreted small bodies). After that time, collisional cooling among small bodies controls the evolution. The efficiency of forming big bodies rises and the size spectrum becomes more top heavy. Trans-Hill growth can terminate in one of two ways, depending on the sizes of the small bodies. First, mutual accretion of big bodies can become significant and conglomeration proceeds until half of the total mass is converted into big bodies

  1. Osseointegration of zirconia implants: an SEM observation of the bone-implant interface.

    Science.gov (United States)

    Depprich, Rita; Zipprich, Holger; Ommerborn, Michelle; Mahn, Eduardo; Lammers, Lydia; Handschel, Jörg; Naujoks, Christian; Wiesmann, Hans-Peter; Kübler, Norbert R; Meyer, Ulrich

    2008-11-06

    The successful use of zirconia ceramics in orthopedic surgery led to a demand for dental zirconium-based implant systems. Because of its excellent biomechanical characteristics, biocompatibility, and bright tooth-like color, zirconia (zirconium dioxide, ZrO2) has the potential to become a substitute for titanium as dental implant material. The present study aimed at investigating the osseointegration of zirconia implants with modified ablative surface at an ultrastructural level. A total of 24 zirconia implants with modified ablative surfaces and 24 titanium implants all of similar shape and surface structure were inserted into the tibia of 12 Göttinger minipigs. Block biopsies were harvested 1 week, 4 weeks or 12 weeks (four animals each) after surgery. Scanning electron microscopy (SEM) analysis was performed at the bone implant interface. Remarkable bone attachment was already seen after 1 week which increased further to intimate bone contact after 4 weeks, observed on both zirconia and titanium implant surfaces. After 12 weeks, osseointegration without interposition of an interfacial layer was detected. At the ultrastructural level, there was no obvious difference between the osseointegration of zirconia implants with modified ablative surfaces and titanium implants with a similar surface topography. The results of this study indicate similar osseointegration of zirconia and titanium implants at the ultrastructural level.

  2. Angiographic differentiation of type of ventricular septal defects

    International Nuclear Information System (INIS)

    Cheon, Mal Soon; Park, Hee Young; Kim, Yang Sook

    1989-01-01

    Defects of the ventricular septum are the commonest type of congenital cardiac malformations. A classification with axial angiography of the subtypes of ventricular septal defects is proposed on the study of 126 patients with defects of the ventricular septum. The results were as follows: 1. The incidence of the ventricular septal defects was 39.6% of congenital heart malformation. 2. The sex distribution of cases were 70 males and 56 females, the age ranged from 13 months to 26 years. 3. Angiographic features seen by axial angiography were as follows: a. Perimembranous defects as seen on long axial view of left ventriculogram were in continuity wity aortic valve. The relation of the defect to the tricuspid valve allows distinction of the extension of the preimembranous defect toward inlet, trabecular, or infundibular zones. This relation was determined angiographically, using the course of the contrast medium from the left ventricle through the ventricular septal defect, opacifying the right ventricle. In inlet excavation, the shunted blood opacified the recess between septal leaflet of tricuspid valve and interventricular septum in early phase, in infundibular excavation, opacified the recess between anterior leaflet of tricuspid valve and anterior free wall of right ventricle and in trabecular excavation, the shunted blood traversed anterior portion of tricuspid valve ring, opacified trabecular portion of right ventricle. b. Muscular defects were separated from the semilunar and atrioventricular valves. c, Subarterial defects were related to both semilunar valves, and they were best demonstrated on the elongated right anterior oblique view of the left ventriculogram. d. Total infundibular defects were profiled in right anterior oblique 30 and long axial view, subaortic in location in both views

  3. Radical feminists & trans activists truce

    OpenAIRE

    Mackay, F.

    2014-01-01

    #GenderWeek: Truce! When radical feminists and trans feminists empathise\\ud Feminist Times\\ud By Finn Mackay \\ud read all #GenderWeek articles.\\ud We wanted to explore the ground between the polarised, entrenched positions in the so-called “TERF-war”. Radical feminists on one pole, trans-inclusionary feminists and trans activists on the other. The disputed territory being women-only space, language and the ever changing legal framework surrounding gender.\\ud Entrenchment leads to stalemate. S...

  4. Implante transapical de endoprótese valvada balão-expansível em posição aórtica sem circulação extracorpórea Off-pump transapical balloon-expandable aortic valve endoprosthesis implantation

    Directory of Open Access Journals (Sweden)

    Diego Felipe Gaia

    2009-06-01

    Full Text Available OBJETIVO: A troca valvar aórtica é procedimento rotineiro, envolve substituição da valva nativa/prótese. Na maioria destes pacientes o risco é aceitável, porém, em alguns casos, o risco predito pode justificar contra-indicação. O implante de valva aórtica minimamente invasivo transcateter e sem circulação extracorpórea (CEC tem se mostrado viável, com menor morbi-mortalidade. O objetivo deste trabalho foi desenvolver bioprótese aórtica, montada em cateter, para implante sem CEC. MÉTODOS: Após desenvolvimento em animais, três pacientes com EuroSCORE elevado foram submetidos ao implante. Caso 1: portador de bioprótese com disfunção; Caso 2: estenose aórtica grave; Caso 3: disfunção de bioprótese aórtica. Após minitoracotomia e sob controle ecocardiográfico e fluoroscópico, cateter-balão foi posicionado sobre posição aórtica e insuflado. Após, segundo cateter-balão, com endoprótese valvada, foi posicionado e liberado sob alta frequência ventricular. Controles angiográficos e ecocardiográficos foram realizados e pacientes encaminhados para UTI. RESULTADOS: No primeiro caso foi possível implante sem CEC com resultados adequados. Evoluiu com melhora da função ventricular. Cursou com broncopneumonia, fístula traqueo-esofágica e óbito por mediastinite. Necropsia confirmou bom posicionamento valvar e preservação dos folhetos. O segundo caso apresentou migração do dispositivo após insuflação do balão, necessidade de esternotomia mediana de urgência, CEC e troca valvar convencional. O paciente evoluiu bem, recebendo alta da UTI 14 dias após procedimento e sem complicações. Cursou com infecção respiratória, choque séptico e óbito no 60º pós-operatório. O terceiro caso foi submetido a implante com sucesso. CONCLUSÃO: O implante de bioprótese transapical montada em cateter sem CEC mostrou ser procedimento factível. Detalhes técnicos e a curva de aprendizado demandam discuss

  5. The management of ventricular dysrhythmia in aconite poisoning.

    Science.gov (United States)

    Coulson, James M; Caparrotta, Thomas M; Thompson, John P

    2017-06-01

    directly correlated with the concentration of aconite alkaloids in the plasma. 54 of 65 cases developed ventricular tachycardia, six developed torsades des pointes, 15 patients developed ventricular fibrillation, 10 developed ventricular ectopics and one developed a broad complex tachycardia not otherwise specified; each dysrhythmia was regarded as separate and patients may have had more than one dysrhythmia. 10 patients died, giving a mortality of 15%. In total, 147 treatments were administered to 65 patients. 46 of the interventions were assessed by the authors as having been associated with successful restoration of sinus rhythm. Flecainide administration was accompanied by dysrhythmia termination in six of seven cases. Mexiletine was connected with correcting dysrhythmias in 3 of 3 cases. Procainamide administration was associated with return to sinus rhythm in 2 of 2 cases. Prolonged cardio-pulmonary resuscitation was administered to 15 patients where it was associated with a return to sinus rhythm in nine of these. Amiodarone was linked to success in correcting dysrhythmias in 11 of 20 cases. Cardiopulmonary bypass use was associated with a return to sinus rhythm in four out of six cases. Epinephrine was documented as being employed on four occasions, and was associated with a restoration of sinus rhythm on two of these. Magnesium sulphate administration was accompanied by dysrhythmia termination in two of nine cases. Direct cardioversion was associated with a return of sinus rhythm in 5 of 30 cases. However, it is not certain whether the drug treatment influenced the course of the dysrhythmia. Based on the evidence available from human case reports, flecainaide or amiodarone appear to be more associated with a return to sinus rhythm than lidocaine and/or cardioversion, although it is not established whether the administration of treatment caused reversion to normal sinus rhythm. The potential beneficial effects of amiodarone were not observed in animal studies. This

  6. Large right ventricular sinusoids in an infant with aorta-left ventricular tunnel and proximal right coronary artery atresia.

    Science.gov (United States)

    Chen, Peter C; Spinner, Joseph A; Heinle, Jeffrey S

    2018-07-01

    We report a 1-month-old infant diagnosed with an aorta-left ventricular tunnel, ventricular septal defect, and right coronary atresia with right ventricular sinusoids. The patient's anatomy and physiology did not indicate right-ventricular-dependent coronary circulation, and therefore right ventricular decompression could be performed without compromising coronary perfusion during surgical correction. A detailed understanding of the coronary anatomy is critical in managing this defect when coronary anomalies are present.

  7. Targeted Victimization and Suicidality Among Trans People: A Web-Based Survey.

    Science.gov (United States)

    Zeluf, Galit; Dhejne, Cecilia; Orre, Carolina; Mannheimer, Louise Nilunger; Deogan, Charlotte; Höijer, Jonas; Winzer, Regina; Thorson, Anna Ekéus

    2018-04-01

    The aim of this study was to investigate the associations between a series of empirically known risk and protective factors and suicidality among trans people in Sweden. Participants were self-selected anonymously to a web-based survey conducted in 2014. Univariable and multivariable logistic regression analyses were performed to assess associations between contributing factors and suicide ideation in the past 12 months and lifetime suicide attempts. The analysis included 796 trans individuals, between 15 and 94 years of age, who live in Sweden. A total of 37% of respondents reported that they have seriously considered suicide during the past 12 months and 32% had ever attempted a suicide. Offensive treatment during the past three months and lifetime exposure to trans-related violence were significantly associated with suicidality. Less satisfaction with contacts with friends and acquaintances and with one's own psychological wellbeing were associated with suicide ideation in the past 12 months. Lack of practical support was associated with lifetime suicide attempts. Our findings show that suicidality is directly correlated with trans-related victimization. Preventing targeted victimization is, therefore, a key preventive intervention against this elevated suicidality.

  8. Association between cell-derived microparticles and adverse events in patients with nonpulsatile left ventricular assist devices.

    Science.gov (United States)

    Nascimbene, Angelo; Hernandez, Ruben; George, Joggy K; Parker, Anita; Bergeron, Angela L; Pradhan, Subhashree; Vijayan, K Vinod; Civitello, Andrew; Simpson, Leo; Nawrot, Maria; Lee, Vei-Vei; Mallidi, Hari R; Delgado, Reynolds M; Dong, Jing Fei; Frazier, O H

    2014-05-01

    Continuous-flow left ventricular assist devices (LVADs) expose blood cells to high shear stress, potentially resulting in the production of microparticles that express phosphatidylserine (PS+) and promote coagulation and inflammation. In this prospective study, we attempted to determine whether PS+ microparticle levels correlate with clinical outcomes in LVAD-supported patients. We enrolled 20 patients undergoing implantation of the HeartMate II LVAD (Thoratec Corp, Pleasanton, CA) and 10 healthy controls who provided reference values for the microparticle assays. Plasma was collected before LVAD implantation, at discharge, at the 3-month follow-up, and when an adverse clinical event occurred. We quantified PS+ microparticles in the plasma using flow cytometry. During the study period, 8 patients developed adverse clinical events: ventricular tachycardia storm in 1, non-ST-elevation myocardial infarction in 2, arterial thrombosis in 2, gastrointestinal bleeding in 2, and stroke in 3. Levels of PS+ microparticles were higher in patients at baseline than in healthy controls (2.11% ± 1.26% vs 0.69% ± 0.46%, p = 0.007). After LVAD implantation, patient PS+ microparticle levels increased to 2.39% ± 1.22% at discharge and then leveled to 1.97% ± 1.25% at the 3-month follow-up. Importantly, levels of PS+ microparticles were significantly higher in patients who developed an adverse event than in patients with no events (3.82% ± 1.17% vs 1.57% ± 0.59%, p microparticle levels may be associated with adverse clinical events. Thus, measuring PS+ microparticle levels in LVAD-supported patients may help identify patients at increased risk for adverse events. Copyright © 2014 International Society for Heart and Lung Transplantation. Published by Elsevier Inc. All rights reserved.

  9. Palliative medicine consultation for preparedness planning in patients receiving left ventricular assist devices as destination therapy.

    Science.gov (United States)

    Swetz, Keith M; Freeman, Monica R; AbouEzzeddine, Omar F; Carter, Kari A; Boilson, Barry A; Ottenberg, Abigale L; Park, Soon J; Mueller, Paul S

    2011-06-01

    To assess the benefit of proactive palliative medicine consultation for delineation of goals of care and quality-of-life preferences before implantation of left ventricular assist devices as destination therapy (DT). We retrospectively reviewed the cases of patients who received DT between January 15, 2009, and January 1, 2010. Of 19 patients identified, 13 (68%) received proactive palliative medicine consultation. Median time of palliative medicine consultation was 1 day before DT implantation (range, 5 days before to 16 days after). Thirteen patients (68%) completed advance directives. The DT implantation team and families reported that preimplantation discussions and goals of care planning made postoperative care more clear and that adverse events were handled more effectively. Currently, palliative medicine involvement in patients receiving DT is viewed as routine by cardiac care specialists. Proactive palliative medicine consultation for patients being considered for or being treated with DT improves advance care planning and thus contributes to better overall care of these patients. Our experience highlights focused advance care planning, thorough exploration of goals of care, and expert symptom management and end-of-life care when appropriate.

  10. Short dental implants versus standard dental implants placed in the posterior jaws: A systematic review and meta-analysis.

    Science.gov (United States)

    Lemos, Cleidiel Aparecido Araujo; Ferro-Alves, Marcio Luiz; Okamoto, Roberta; Mendonça, Marcos Rogério; Pellizzer, Eduardo Piza

    2016-04-01

    The purpose of the present systematic review and meta-analysis was to compare short implants (equal or less than 8mm) versus standard implants (larger than 8mm) placed in posterior regions of maxilla and mandible, evaluating survival rates of implants, marginal bone loss, complications and prosthesis failures. This review has been registered at PROSPERO under the number CRD42015016588. Main search terms were used in combination: dental implant, short implant, short dental implants, short dental implants posterior, short dental implants maxilla, and short dental implants mandible. An electronic search for data published up until September/2015 was undertaken using the PubMed/Medline, Embase and The Cochrane Library databases. Eligibility criteria included clinical human studies, randomized controlled trials and/or prospective studies, which evaluated short implants in comparison to standard implants in the same study. The search identified 1460 references, after inclusion criteria 13 studies were assessed for eligibility. A total of 1269 patients, who had received a total of 2631 dental implants. The results showed that there was no significant difference of implants survival (P=.24; RR:1.35; CI: 0.82-2.22), marginal bone loss (P=.06; MD: -0.20; CI: -0.41 to 0.00), complications (P=.08; RR:0.54; CI: 0.27-1.09) and prosthesis failures (P=.92; RR:0.96; CI: 0.44-2.09). Short implants are considered a predictable treatment for posterior jaws. However, short implants with length less than 8 mm (4-7 mm) should be used with caution because they present greater risks to failures compared to standard implants. Short implants are frequently placed in the posterior area in order to avoid complementary surgical procedures. However, clinicians need to be aware that short implants with length less than 8mm present greater risk of failures. Copyright © 2016. Published by Elsevier Ltd.

  11. Pengaruh Kualitas Pelayanan Dan Nilai Pelanggan Terhadap Kepuasan Dan Loyalitas Pelanggan Trans Metro Pekanbaru

    OpenAIRE

    Harpadeles, Ian; ', Jushermi; Nursanti, Aida

    2016-01-01

    This study aims to measure the impact of service quality and customer value on customer satisfaction and loyalty Trans Metro Pekanbaru. The population in this study is the Trans Metro Pekanbaru customers with a total sample of 100 respondents, using purposive sampling technique. Analysis of data using path analysis with SPSS version 17.0. The results showed that the variables of service quality significantly influence customer satisfaction. Customer value significantly influence customer sati...

  12. Relic dark energy from the trans-Planckian regime

    International Nuclear Information System (INIS)

    Mersini, Laura; Bastero-Gil, Mar; Kanti, Panagiota

    2001-01-01

    As yet, there is no underlying fundamental theory for the trans-Planckian regime. There is a need to address the issue of how the observables in our present Universe are affected by processes that may have occurred at super-Planckian energies (referred to as the trans-Planckian regime). Specifically, we focus on the impact the trans-Planckian regime has on two observables: namely, dark energy and the cosmic microwave background radiation (CMBR) spectrum. We model the trans-Planckian regime by introducing a 1-parameter family of smooth non-linear dispersion relations which modify the frequencies at very short distances. A particular feature of the family of dispersion functions chosen is the production of ultralow frequencies at very high momenta k (for k>M P ). We name the range of the ultralow energy modes (of very short distances) that have frequencies equal to or less than the current Hubble rate H 0 as the tail modes. These modes are still frozen today due to the expansion of the Universe. We calculate their energy today and show that the tail provides a strong candidate for the dark energy of the Universe. During inflation, their energy is about 122 to 123 orders of magnitude smaller than the total energy, for any random value of the free parameter in the family of dispersion relations. For this family of dispersions, we present the exact solutions and show that the CMBR spectrum is that of a (nearly) blackbody, and that the adiabatic vacuum is the only choice for the initial conditions

  13. Experiences from Auditory Brainstem Implantation (ABIs) in four paediatric patients.

    Science.gov (United States)

    Lundin, Karin; Stillesjö, Fredrik; Nyberg, Gunnar; Rask-Andersen, Helge

    2016-01-01

    Indications for auditory brainstem implants (ABIs) have been widened from patients with neurofibromatosis type 2 (NF2) to paediatric patients with congenital cochlear malformations, cochlear nerve hypoplasia/aplasia, or cochlear ossification after meningitis. We present four ABI surgeries performed in children at Uppsala University Hospital in Sweden since 2009. Three children were implanted with implants from Cochlear Ltd. (Lane Cove, Australia) and one child with an implant from MedEl GMBH (Innsbruck, Austria). A boy with Goldenhar syndrome was implanted with a Cochlear Nucleus ABI24M at age 2 years (patient 1). Another boy with CHARGE syndrome was implanted with a Cochlear Nucleus ABI541 at age 2.5 years (patient 2). Another boy with post-ossification meningitis was implanted with a Cochlear Nucleus ABI24M at age 4 years (patient 3). A girl with cochlear aplasia was implanted with a MedEl Synchrony ABI at age 3 years (patient 4). In patients 1, 2, and 3, the trans-labyrinthine approach was used, and in patient 4 the retro-sigmoid approach was used. Three of the four children benefited from their ABIs and use it full time. Two of the full time users had categories of auditory performance (CAP) score of 4 at their last follow up visit (6 and 2.5 years postoperative) which means they can discriminate consistently any combination of two of Ling's sounds. One child has not been fully evaluated yet, but is a full time user and had CAP 2 (responds to speech sounds) after 3 months of ABI use. No severe side or unpleasant stimulation effects have been observed so far. There was one case of immediate electrode migration and one case of implant device failure after 6.5 years. ABI should be considered as an option in the rehabilitation of children with similar diagnoses.

  14. Platypnea-Orthodeoxia Syndrome after Transcatheter Aortic Valve Implantation

    Directory of Open Access Journals (Sweden)

    Andrew K. Roy

    2016-01-01

    Full Text Available Progressive dyspnea and hypoxaemia in the subacute phase after transcatheter aortic valve implantation (TAVI are uncommon and warrant immediate assessment of valve and prosthesis leaflet function to exclude thrombosis, as well as investigation for other causes related to the procedure, such as left ventricular dysfunction, pulmonary embolism, and respiratory sepsis. In this case, we report the observation of a patient presenting two weeks after TAVI with arterial hypoxaemia in an upright position, relieved by lying flat, and coupled with an intracardiac shunt detected on echocardiography in the absence of pulmonary hypertension, raising the suspicion of Platypnea-Orthodeoxia Syndrome (POS. Invasive intracardiac haemodynamic assessment showed a significant right-to-left shunt (Qp/Qs = 0.74, which confirmed the diagnosis, with subsequent closure of the intracardiac defect resulting in immediate relief of symptoms and hypoxaemia. To our knowledge, this is the first reported case of an interatrial defect and shunt causing Platypnea-Orthodeoxia Syndrome after transcatheter aortic valve implantation, resolved by percutaneous device closure.

  15. Trans advanced surface laser ablation (TransPRK) outcomes using SmartPulseTechnology.

    Science.gov (United States)

    Aslanides, Ioannis M; Kymionis, George D

    2017-02-01

    To evaluate early visual rehabilitation, post-operative pain, epithelial healing and haze after transepithelial photorefractive keratectomy (TransPRK) using the SmartPulseTechnology (SPT) of Schwind Amaris (Schwind eye-tech-solutions GmbH, Kleinostheim, Germany). This was a retrospective comparative evaluation of a cohort of myopic patients undergoing TransPRK with SPT (group 1), with one matched control group that underwent conventional TransPRK (group 2). All cases had a 6-month post-operative follow-up including visual acuity and slit-lamp examination. Subjective evaluation of pain was recorded post-operatively. 49 eyes of 25 patients in group 1 and 40 eyes of 20 patients in group 2 were enrolled. The patients' visual rehabilitation was significantly faster in group 1, one day and one week post-operatively (P0.05). TransPRK using SPT provides promising results in the early post-operative period. Visual rehabilitation, re-epithelialization and pain were faster in the early post-operative period in group 1 in comparison with group 2. Haze formation was not significantly different between the two groups; however, it was consistently less in group 1. Copyright © 2016 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  16. Trans as Contested Intelligibility

    DEFF Research Database (Denmark)

    Raun, Tobias

    2014-01-01

    Denne artikel rejser en række epistemologiske og metodologiske spørgsmål vedrørende læsningen af trans som identitetskategori. Disse spørgsmål er stærkt underbelyste i en skandinavisk akademisk kontekst, om end der el- lers i stigende grad produceres analyser af trans identitetsnarrativer. Artikl...

  17. Total DNA of Glycyrrhiza uralensis transformed into Hansenula anomala by ion implantation:Preparing Glycyrrhizic acid in recombined yeasts

    International Nuclear Information System (INIS)

    Jin Xiang; Mao Peihong; Lu Jie; Ma Yuan

    2010-01-01

    Glycyrrhizic acid (GA) in Glycyrrhiza uralensis (G. uralensis) is physiologically active. In this study, the total DNA of wild G. uralensis was randomly transformed into Hansenula anomaly by implantation of low-energy Ar + and N + , to produce five recombinant yeast strains relating to biological synthesis of the GA or Glycyrrhetinic acid (GAs). After culturing in liquid medium for 96 h, the resultant GA, 18α-GAs and 18β-Gas were determined by reversed-phase high performance liquid chromatography (RP-HPLC), and the corresponding concentrations were 114.49, 0.56, and 0.81 mg·L -1 . After one hundred primers were analyzed with random amplified polymorphic DNA (RAPD), the seven different DNA fragments were produced by the N7059 strain of recombined yeasts, and, the polymerase chain reaction (PCR) verified that one of them came from the genome of G. uralensis, indicating a successful transfer of genetic information by ion implantation. (authors)

  18. Uniform implantation of CNTs on total activated carbon surfaces: a smart engineering protocol for commercial supercapacitor applications.

    Science.gov (United States)

    Jiang, Jian; Li, Linpo; Liu, Yani; Liu, Siyuan; Xu, Maowen; Zhu, Jianhui

    2017-04-07

    The main obstacles to building better supercapacitors are still trade-offs between energy and power parameters. To promote commercial supercapacitor behaviors, proper optimization toward electrode configurations/architectures may be a feasible and effective way. We herein propose a smart and reliable electrode engineering protocol, by in situ implantation of carbon nanotubes (CNTs) on total activated carbon (AC) surfaces via a mild chemical vapor deposition process at ∼550 °C, using nickel nitrate hydroxide (NNH) thin films and waste ethanol solvents as the catalyst and carbon sources, respectively. The direct and conformal growth of NNH layers onto carbonaceous scaffold guarantees the later uniform implantation of long and high-quality CNTs on total AC outer surfaces. Such fluffy and entangled CNTs preserve ionic diffusion channels, well connect neighboring ACs and function as superhighways for electrons transfer, endowing electrodes with outstanding capacitive behaviors including large output capacitances of ∼230 F g -1 in 1 M Na 2 SO 4 neutral solution and ∼502.5 F g -1 in 6 M KOH using Ni valence state variation, and very negligible capacity decay in long-term cycles. Furthermore, a full symmetric supercapacitor device of CNTs@ACs//CNTs@ACs has been constructed, capable of delivering both high specific energy and power densities (maximum values reaching up to ∼97.2 Wh kg -1 and ∼10.84 kW kg -1 ), which holds great potential in competing with current mainstream supercapacitors.

  19. Role of ventricular tachycardia ablation in arrhythmogenic right ventricular cardiomyopathy

    Directory of Open Access Journals (Sweden)

    Alberto Cipriani

    2017-11-01

    Full Text Available Arrhythmogenic right ventricular cardiomyopathy (ARVC is characterized by progressive fibro-fatty replacement of the myocardium that represents the substrate for recurrent sustained ventricular tachycardia (VT. These arrhythmias characterize the clinical course of a sizeable proportion of patients and have significant implications for their quality of life and long-term prognosis. Antiarrhythmic drugs are often poorly tolerated and usually provide incomplete control of arrhythmia relapses. Catheter ablation is a potentially effective strategy to treat frequent VT episodes and ICD shocks in ARVC patients. The aims of this review are to discuss the electrophysiological and electroanatomic substrates of ventricular tachycardia in patients with ARVC and to analyze the role of catheter ablation in their management with particular reference to selection of patients, technical issues, potential complications and outcomes.

  20. A comparison of 500 prefilled textured saline breast implants versus 500 standard textured saline breast implants: is there a difference in deflation rates?

    Science.gov (United States)

    Stevens, W Grant; Hirsch, Elliot M; Stoker, David A; Cohen, Robert

    2006-06-01

    This study provides the first large-volume (1000 implant) comparison of the deflation rates of Poly Implant Prosthesis prefilled textured saline breast implants versus a control group of Mentor Siltex textured saline implants. A consecutive series of 500 Poly Implant Prosthesis prefilled textured saline breast implants was compared with a consecutive series of 500 Mentor Siltex breast implants. Each breast implant was evaluated for a 4-year period, and the annual deflation rate (number of deflations during a given year divided by the total number of implants) and cumulative deflation rate (cumulative total of deflations through a given year divided by the total number of implants) were recorded. Statistical significance was calculated using the Fisher's exact test at year 1 and the chi-square analysis at years 2 through 4. The cumulative deflation rates of the Poly Implant Prosthesis implants was as follows: year 1, 1.2 percent; year 2, 5.6 percent; year 3, 11.4 percent; and year 4, 15.4 percent. The cumulative deflation rates of the Mentor implants was: year 1, 0.2 percent; year 2, 0.6 percent; year 3, 1.6 percent; and year 4, 4.4 percent. At year 1, the difference between deflation rates was not statistically significant (Fisher's exact test, p > 0.05). However, at year 2 (chi-square, 13.29; p deflation rates of Poly Implant Prosthesis prefilled textured saline breast implants and Mentor Siltex breast implants at year 2, year 3, and year 4. After 4 years, the 15.56 percent cumulative deflation rate of Poly Implant Prosthesis implants was over 3.5 times higher than the 4.31 percent deflation rate of the Mentor Siltex implants. There may be several factors contributing to the higher deflation rate seen in Poly Implant Prosthesis implants, including possible in vitro deflation before implantation and silicone shell curing technique. Nevertheless, this statistically significant deflation difference must be taken into account when balancing the risks and benefits of

  1. Splenic implant preservation after conservation in lactated Ringer´s solution

    OpenAIRE

    MATOS FILHO, ARGOS SOARES DE; PETROIANU, ANDY; CARDOSO, VALBERT NASCIMENTO; VIDIGAL, PAULA VIEIRA TEIXEIRA

    2018-01-01

    ABSTRACT Objective: to evaluate the morphology and function of autogenous splenic tissue implanted in the greater omentum, 24 hours after storage in Ringer-lactate solution. Methods: we divided 35 male rats into seven groups (n=5): Group 1: no splenectomy; Group 2: total splenectomy without implant; Group 3: total splenectomy and immediate autogenous implant; Group 4: total splenectomy, preservation of the spleen in Ringer-lactate at room temperature, then sliced and implanted; Group 5: tot...

  2. Total Artificial Heart Implantation as a Bridge to Heart Transplantation in an Active Duty Service Member With Amyloid Cardiomyopathy.

    Science.gov (United States)

    Scully, Michael S; Wessman, Dylan E; McKee, James M; Francisco, Gregory M; Nayak, Keshav R; Kobashigawa, Jon A

    2017-03-01

    Cardiac involvement by light-chain (AL) amyloid occurs in up to 50% of patients with primary AL amyloidosis. The prognosis of amyloid heart disease is poor with 1-year survival rates of 35 to 40%. Historically, heart transplantation was considered controversial for patients with AL amyloid cardiomyopathy (CM) given the systemic nature of the disease and poor survival. We present a case report of an active duty service member diagnosed with advanced cardiac amyloid who underwent total artificial heart transplant as a bridge to heart transplant and eventual autologous stem cell transplant. A 47-year-old active duty male initially evaluated for atypical chest pain was found to have severe concentric left ventricular hypertrophy on echocardiogram but normal voltage on electrocardiogram. Cardiac magnetic resonance imaging, laboratory studies, and bone marrow biopsy established the diagnosis of cardiac amyloidosis. At the time of diagnosis, the patient's prognosis was very poor with a median survival of 5 months on the basis of the Mayo Clinic revised prognostic staging system for amyloidosis. The patient developed rapidly progressive left ventricular dysfunction and heart failure leading to cardiac arrest. The patient received a total artificial heart as a bridge to orthotopic heart and kidney transplantation and eventual stem cell transplant. He continues to be in remission and has a fair functional capacity without restriction in activities of daily living or moderate exercise. Amyloid CM is a rare and devastating disease. The natural course of the disease has made heart transplant in these patients controversial. Modern advancements in chemotherapies and advanced heart failure treatments have improved outcomes for select patients with AL amyloid CM undergoing heart transplantation. There is ongoing research seeking improvement in treatment options and outcomes for patients with this deadly disease. Reprint & Copyright © 2017 Association of Military Surgeons of the U.S.

  3. Recall management of patients with Rofil Medical breast implants.

    Science.gov (United States)

    Schott, Sarah; Bruckner, Thomas; Golatta, Michael; Wallwiener, Markus; Küffner, Livia; Mayer, Christine; Paringer, Carmen; Domschke, Christoph; Blumenstein, Maria; Schütz, Florian; Sohn, Christof; Heil, Joerg

    2014-07-01

    Some Rofil Medical breast implants are relabelled Poly Implant Prothèse (PIP) implants, and it is recommended that Rofil implants be managed in the same way as PIP implants. We report the results of a systematic recall of patients who had received Rofil implants. All patients who received Rofil implants at our centre were identified and invited for specialist consultation. In patients who opted for explantation, preoperative and intraoperative work-up was performed in accordance with national guidelines and analysed. In cases suspicious for rupture, an MRI scan was performed. Two-hundred and twenty-five patients (average age 56; range 28-80) received a total of 321 Rofil implants an average of 5.8 (range 1-11) years previously, 225/321 (70%) implants were used for reconstruction after breast cancer. A total of 43 implants were removed prior to 2011, mainly due to capsular contracture (CC). A total of 188 patients were still affected at the time of recall. Of the 188 patients, 115 (61%) attended for specialist consultation, of which 50 (44%) requested immediate implant removal. To date, 72 of 115 (63%) women attending consultation (38% of all affected) have chosen explantation, 66 of 72 (92%) opting for new implants. Of the 108 explanted implants, 25 (23%) had capsular rupture and 57 (53%) had implant bleeding. Preoperative clinical assessment was unreliable for predicting CC or rupture. The majority of patients attended for consultation and requested explantation. The quality of the explanted Rofil implants was comparable to PIP implants, with a higher rupture prevalence compared with other, non-affected implants. Nevertheless, the acceptance of breast implants for reimplantation remained high. Copyright © 2014 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  4. Radiological evaluation of ventricular septal defect with aortic insufficiency - An analysis of cineangiography in 15 cases -

    International Nuclear Information System (INIS)

    Park, Jae Hyung; Yeon, Kyung Mo; Han, Man Chung

    1981-01-01

    Fifteen cases of ventricular septal defect with aortic insufficiency were diagnosed radiographically and confirmed after operation at Seoul National University Hospital in recent two half years since 1979. Cineangiographies of ascending aorta and left ventricle were done in those cases and revealed some characteristic findings. The results of the analysis are as follow: 1. Among the 15 cases, 14 cases were male and 1 case was female. Age distribution was from 7 years to 23 years. 2. Those 15 cases were corresponded to 8% among total 193 cases of ventricular septal defect, to 11% among total 135 cases of aortic insufficiency and especially to 48% among 48 cases of aortic insufficiency below age of 20 years. 3. After operation, 11 cases were confirmed as subpulmonary type ventricular septal defect and 4 cases as subcristal type. The sizes of the ventricular septal defects were ranged between 0.6 and 2.5 cm in diameter. 4. Regurgitation of contrast media was noticed in cine aortography of all cases, and the grades of regurgitation were II-III/IV in 13 cases. 5. Various types of herniated aortic cusp through ventricular septal defect were seen. In the cases of subpulmonary ventricular septal defect characteristic saccular aneurysm was found in 7 cases. Asymmetry or mild bulging of aortic sinus was found in the cases of subcristal ventricular septal defect. 6. Infundibular stenosis was found in 3 cases with right ventriculography and those were caused by the herniated saccular aneurysm of aortic cusp. 7. It is essential for the diagnosis of ventricular septal defect with aortic insufficiency to undertake biplane cineangiography of ascending aorta and left ventricle in long axial view and right ventriculography should be done in suspicion of infundibular pulmonary stenosis

  5. Dynamic Changes of QRS Morphology of Premature Ventricular Contractions During Ablation in the Right Ventricular Outflow Tract: A Case Report.

    Science.gov (United States)

    Yue-Chun, Li; Jia-Feng, Lin; Jia-Xuan, Lin

    2015-10-01

    Electrocardiographic characteristics can be useful in differentiating between right ventricular outflow tract (RVOT) and aortic sinus cusp (ASC) ventricular arrhythmias. Ventricular arrhythmias originating from ASC, however, show preferential conduction to RVOT that may render the algorithms of electrocardiographic characteristics less reliable. Even though there are few reports describing ventricular arrhythmias with ASC origins and endocardial breakout sites of RVOT, progressive dynamic changes in QRS morphology of the ventricular arrhythmias during ablation obtained were rare.This case report describes a patient with symptomatic premature ventricular contractions of left ASC origin presenting an electrocardiogram (ECG) characteristic of right ventricular outflow tract before ablation. Pacing at right ventricular outflow tract reproduced an excellent pace map. When radiofrequency catheter ablation was applied to the right ventricular outflow tract, the QRS morphology of premature ventricular contractions progressively changed from ECG characteristics of right ventricular outflow tract origin to ECG characteristics of left ASC origin.Successful radiofrequency catheter ablation was achieved at the site of the earliest ventricular activation in the left ASC. The distance between the successful ablation site of the left ASC and the site with an excellent pace map of the RVOT was 20 mm.The ndings could be strong evidence for a preferential conduction via the myocardial bers from the ASC origin to the breakout site in the right ventricular outflow tract. This case demonstrates that ventricular arrhythmias with a single origin and exit shift may exhibit QRS morphology changes.

  6. Right ventricular pacemaker lead position is associated with differences in long-term outcomes and complications.

    Science.gov (United States)

    Witt, Chance M; Lenz, Charles J; Shih, Henry H; Ebrille, Elisa; Rosenbaum, Andrew N; van Zyl, Martin; Aung, Htin; Manocha, Kevin K; Deshmukh, Abhishek J; Hodge, David O; Mulpuru, Siva K; Cha, Yong-Mei; Espinosa, Raul E; Asirvatham, Samuel J; Mcleod, Christopher J

    2017-08-01

    Cardiac pacing from the right ventricular apex is associated with detrimental long-term effects and nonapical pacing locations may be associated with improved outcomes. There is little data regarding complications with nonapical lead positions. The aim of this study was to assess long-term outcomes and lead-related complications associated with differing ventricular lead tip position. All adult patients who underwent dual-chamber pacemaker implantation from 2004 to 2014 were included if they had postprocedure chest radiographs amenable to lead position determination. Long-term outcomes and lead-related complication rates were recorded. These were compared at 5 years between: (1) apical and septal leads, (2) apical and nonseptal nonapical (NSNA), and (3) apical and septal with >40% ventricular pacing. We retrospectively evaluated 3,450 patients, which included 238 with a septal position and 733 with NSNA lead positions. Septal lead position was associated with a lower mortality compared to apical leads (24% vs. 31%, P = 0.02). In patients with greater than 40% pacing, septal leads were associated with significantly higher rates of incident atrial fibrillation compared to apical leads (49% vs. 34%, P = 0.04). NSNA positions were associated with a significantly higher rate of lead dislodgement (4% vs. 2%, P = 0.005) and need for revision (8% vs. 5%, P = 0.005). Septal pacemaker lead position is associated with a lower mortality compared to apically placed leads, but a higher incidence of atrial fibrillation with higher percentage ventricular pacing. NSNA lead locations are associated with more complications and should be avoided. © 2017 Wiley Periodicals, Inc.

  7. Trans trochanteric approach with coronal osteotomy of the great trochanter

    Directory of Open Access Journals (Sweden)

    Steffann Francois

    2015-01-01

    Full Text Available Several surgical approaches could be used in hip arthroplasty or trauma surgery: anterior, anterolateral, lateral, posterior (with or without trochanterotomy, using or not an orthopedic reduction table. Subtrochanteric and extra-capsular trochanteric fractures (ECTF are usually treated by internal fixation with mandatory restrictions on weight bearing. Specific complications have been widely described. Mechanical failures are particularly high in unstable fractures. Hip fractures are a major public health issue with a mortality rate of 12%–23% at 1 year. An alternative option is to treat ECTF by total hip arthroplasty (THA to prevent decubitus complications, to help rapid recovery, and to permit immediate weight bearing as well as quick rehabilitation. However, specific risks of THA have to be considered such as dislocation or cardiovascular failure. The classical approach (anterior or posterior requires the opening of the joint and capsule, weakening hip stability and the repair of the great trochanter is sometimes hazardous. For 15 years, we have been treating unstable ECTF by THA with cementless stem, dual mobility cup (DMC, greater trochanter (GT reattachment, and a new surgical approach preserving capsule, going through the fracture and avoiding joint dislocation. Bombaci first described a similar approach in 2008; our trans fractural digastric approach (medial gluteus and lateral vastus is different. A coronal GT osteotomy is performed when there is no coronal fracture line. It allows easy access to the femoral neck and acetabulum. The THA is implanted without femoral internal rotation to avoid extra bone fragment displacement. With pre-operative planning, cup implantation is easy and stem positioning is adjusted referring to the top of the GT after trial reduction and preoperative planning. The longitudinal osteotomy and trochanteric fracture are repaired with wires and the digastric incision is closed. This variant of Bombaci

  8. Left ventricular assist device implantation in a patient who had previously undergone apical myectomy for hypertrophic cardiomyopathy.

    Science.gov (United States)

    Cho, Yang Hyun; Deo, Salil V; Topilsky, Yan; Grogan, Martha A; Park, Soon J

    2012-03-01

    Apical hypertrophy is a rare variant of hypertropic cardiomyopathy. These patients may present with end-stage congestive heart failure subsequent to long standing diastolic dysfunction. We report the technique for left ventricular assist device insertion in a patient with previous apical myectomy for hypertrophic cardiomyopathy. © 2012 Wiley Periodicals, Inc.

  9. The Danish trans-fatty acids ban

    DEFF Research Database (Denmark)

    Vallgårda, Signild

    2017-01-01

    In 2003 an executive order was issued banning industrially produced trans-fatty acids above a low level in food items in Denmark. To date, only a few other countries have followed Denmark’s example. The way health consequences of trans fats were translated by the different actors enabled the crea......In 2003 an executive order was issued banning industrially produced trans-fatty acids above a low level in food items in Denmark. To date, only a few other countries have followed Denmark’s example. The way health consequences of trans fats were translated by the different actors enabled...

  10. Potential energy profile, structural, vibrational and reactivity descriptors of trans-2-methoxycinnamic acid by FTIR, FT-Raman and quantum chemical studies

    Science.gov (United States)

    Arjunan, V.; Anitha, R.; Thenmozhi, S.; Marchewka, M. K.; Mohan, S.

    2016-06-01

    The stable conformers of trans-2-methoxycinnamic acid (trans-2MCA) are determined by potential energy profile analysis. The energies of the s-cis and s-trans conformers of trans-2MCA determined by B3LYP/cc-pVTZ method are -612.9788331 Hartrees and -612.9780953 Hartrees, respectively. The vibrational and electronic investigations of the stable s-cis and s-trans conformers of trans-2-methoxycinnamic acid have been carried out extensively with FTIR and FT-Raman spectral techniques. The s-cis conformer (I) with a (C16-C17-C18-O19) dihedral angle equal to 0° is found to be more favoured relative to the one s-trans (II) with (C16-C17-C18-O19) = 180°, possibly due to delocalization, hydrogen bonding and steric repulsion effects between the methoxy and acrylic acid groups. The DFT studies are performed with B3LYP method by utilizing 6-311++G** and cc-pVTZ basis sets to determine the structure, thermodynamic properties, vibrational characteristics and chemical shifts of the compound. The total dipole moments of the conformers determined by B3LYP/cc-pVTZ method are 3.35 D and 4.87 D for s-cis and s-trans, respectively. It reveals the higher polarity of s-trans conformer of trans-2MCA molecule. The electronic and steric influence of the methoxy group on the skeletal frequencies has been analysed. The energies of the frontier molecular orbitals and the LUMO-HOMO energy gap have been determined. The MEP of s-cis conformer lie in the range +1.374e × 10-2 to -1.374e × 10-2 while for s-trans it is +1.591e × 10-2 to -1.591e × 10-2. The total electron density of s-cis conformer lie in the range +5.273e × 10-2 to -5.273e × 10-2 while for s-trans it is +5.403e × 10-2 to -5.403e × 10-2. The MEP and total electron density shows that the s-cis conformer is less polar, less reactive and more stable than the s-trans conformer. All the reactivity descriptors of the molecule have been discussed. Intramolecular electronic interactions and their stabilisation energies have analysed

  11. Transcatheter leadless pacemaker implantation in a patient with a transvenous dual-chamber pacemaker already in place.

    Science.gov (United States)

    Karjalainen, Pasi P; Nammas, Wail; Paana, Tuomas

    2016-01-01

    An 83-year-old lady had a DDDR pacemaker inserted in 1997 for symptomatic atrioventricular block. She underwent battery replacement in 2008. In 2010, she developed atrial fibrillation; the pacemaker was switched to VVIR mode. During the last 2years, ventricular lead threshold increased progressively. In December 2015, she presented for elective battery replacement. After successful battery replacement, the ventricular lead threshold remained high; therefore, we implanted a leadless transcatheter pacemaker, via femoral vein access, using a dedicated catheter delivery system. Electrical measurements at this stage revealed a pacing threshold of 0.28V at 0.24msec, and an impedance of 650Ω. Copyright © 2016 Elsevier Inc. All rights reserved.

  12. Ventricular enlargement in patients with affective disorders

    International Nuclear Information System (INIS)

    Murashita, Jun; Kato, Tadafumi; Shioiri, Toshiki; Hamakawa, Inubushi, Toshiro; Hiroshi; Takahashi, Saburo

    1994-01-01

    Ventricular enlargement was determined using linear measurement on MR images in a total of 71 patients with affective disorders, including bipolar affective disorder (41) and depression (30). Fourty-one healthy persons served as controls. Evans ratio, Huckman number and minimum distance of caudate nuclei (MDCN) were used as indices for ventricular enlargment. No significant difference in Evans ratio was observed between both the group of bipolar affective disorder and the group of depression and the control group. Nor did it correlate with age in any of the groups. Huckman number was significantly higher in the group of bipolar affective disorder than the other two groups. It positively correlated with age in the group of depression. MDCN was significantly increased in the group of bipolar affective disorder, as compared with the control group; and there was a positive correlation between MDCN and age in both the group of dipolar affective disorder and the group of depression. In conclusion, ventricular enlargement was dependent upon aging in affetive disorder patients. This tendency was more noticeable in the group of depression. In addition, atrophy of the caudate nuclei was likely to be severer in the group of dipolar affective disorder than the group of depression. (N.K.)

  13. PAIN RELIEF MEDIATED BY IMPLANTABLE DRUG-DELIVERY DEVICES

    NARCIS (Netherlands)

    HOEKSTRA, A

    Various totally implantable drug delivery systems from single access ports to micropumps are now available for administration of repeated boluses, and continuous or programmable infusions. In this respect, emphasis is given to a relatively cheap, totally implantable system for self-administering

  14. Outflow monitoring of a pneumatic ventricular assist device using external pressure sensors.

    Science.gov (United States)

    Kang, Seong Min; Her, Keun; Choi, Seong Wook

    2016-08-25

    In this study, a new algorithm was developed for estimating the pump outflow of a pneumatic ventricular assist device (p-VAD). The pump outflow estimation algorithm was derived from the ideal gas equation and determined the change in blood-sac volume of a p-VAD using two external pressure sensors. Based on in vitro experiments, the algorithm was revised to consider the effects of structural compliance caused by volume changes in an implanted unit, an air driveline, and the pressure difference between the sensors and the implanted unit. In animal experiments, p-VADs were connected to the left ventricles and the descending aorta of three calves (70-100 kg). Their outflows were estimated using the new algorithm and compared to the results obtained using an ultrasonic blood flow meter (UBF) (TS-410, Transonic Systems Inc., Ithaca, NY, USA). The estimated and measured values had a Pearson's correlation coefficient of 0.864. The pressure sensors were installed at the external controller and connected to the air driveline on the same side as the external actuator, which made the sensors easy to manage.

  15. Observational studies are compatible with an association between saturated and trans fats and cardiovascular disease

    OpenAIRE

    Hooper, Lee; Mann, Jim

    2016-01-01

    Context What is the relationship between saturated or trans fats in our food and cardiovascular risk? To find out we must examine the totality of interventional and observational evidence, and all appropriate outcomes. The World Health Organization Nutrition Guidance Advisory Group (WHO NUGAG) recently commissioned systematic reviews of randomised controlled trials (RCTs) which examined effects of modifying saturated or trans fat intakes on mortality or cardiovascular health1, 2 and controlle...

  16. Splenic implant preservation after conservation in lactated Ringer´s solution.

    Science.gov (United States)

    Matos Filho, Argos Soares DE; Petroianu, Andy; Cardoso, Valbert Nascimento; Vidigal, Paula Vieira Teixeira

    2018-01-01

    to evaluate the morphology and function of autogenous splenic tissue implanted in the greater omentum, 24 hours after storage in Ringer-lactate solution. we divided 35 male rats into seven groups (n=5): Group 1: no splenectomy; Group 2: total splenectomy without implant; Group 3: total splenectomy and immediate autogenous implant; Group 4: total splenectomy, preservation of the spleen in Ringer-lactate at room temperature, then sliced ​​and implanted; Group 5: total splenectomy, ​​spleen sliced and preserved in Ringer-lactate at room temperature before implantation; Group 6: total splenectomy with preservation of the spleen in Ringer-lactate at 4°C and then sliced ​​and implanted; Group 7: total splenectomy and the spleen sliced for preservation in Ringer-lactate at 4°C before implantation. After 90 days, we performed scintigraphic studies with Tc99m-colloidal tin (liver, lung, spleen or implant and clot), haematological exams (erythrogram, leucometry, platelets), biochemical dosages (protein electrophoresis) and anatomopathological studies. regeneration of autogenous splenic implants occurred in the animals of the groups with preservation of the spleen at 4ºC. The uptake of colloidal tin was higher in groups 1, 3, 6 and 7 compared with the others. There was no difference in hematimetric values ​​in the seven groups. Protein electrophoresis showed a decrease in the gamma fraction in the group of splenectomized animals in relation to the operated groups. the splenic tissue preserved in Ringer-lactate solution at 4ºC maintains its morphological structure and allows functional recovery after being implanted on the greater omentum.

  17. Splenic implant preservation after conservation in lactated Ringer´s solution

    Directory of Open Access Journals (Sweden)

    ARGOS SOARES DE MATOS FILHO

    2018-02-01

    Full Text Available ABSTRACT Objective: to evaluate the morphology and function of autogenous splenic tissue implanted in the greater omentum, 24 hours after storage in Ringer-lactate solution. Methods: we divided 35 male rats into seven groups (n=5: Group 1: no splenectomy; Group 2: total splenectomy without implant; Group 3: total splenectomy and immediate autogenous implant; Group 4: total splenectomy, preservation of the spleen in Ringer-lactate at room temperature, then sliced and implanted; Group 5: total splenectomy, spleen sliced and preserved in Ringer-lactate at room temperature before implantation; Group 6: total splenectomy with preservation of the spleen in Ringer-lactate at 4°C and then sliced and implanted; Group 7: total splenectomy and the spleen sliced for preservation in Ringer-lactate at 4°C before implantation. After 90 days, we performed scintigraphic studies with Tc99m-colloidal tin (liver, lung, spleen or implant and clot, haematological exams (erythrogram, leucometry, platelets, biochemical dosages (protein electrophoresis and anatomopathological studies. Results: regeneration of autogenous splenic implants occurred in the animals of the groups with preservation of the spleen at 4ºC. The uptake of colloidal tin was higher in groups 1, 3, 6 and 7 compared with the others. There was no difference in hematimetric values in the seven groups. Protein electrophoresis showed a decrease in the gamma fraction in the group of splenectomized animals in relation to the operated groups. Conclusion: the splenic tissue preserved in Ringer-lactate solution at 4ºC maintains its morphological structure and allows functional recovery after being implanted on the greater omentum.

  18. Arrhythmogenic right ventricular dysplasia: MRI findings

    International Nuclear Information System (INIS)

    Wall, E.E. van der; Bootsma, M.M.; Schalij, M.J.; Kayser, H.W.M.; Roos, A. de

    2000-01-01

    Arrhythmogenic right ventricular dysplasia (ARVD) is a heart muscle disorder of unknown cause that is characterized pathologically by fibrofatty replacement of the right ventricular myocardium. Clinical manifestations include structural and functional malformations of the right ventricle, electrocardiographic abnormalities, and presentation with ventricular tachycardias with left bundle branch pattern or sudden death. The disease is often familial with an autosomal inheritance. In addition to right ventricular dilatation, right ventricular aneurysms are typical deformities of ARVD and they are distributed in the so-called ''triangle of dysplasia'', i. e., right ventricular outflow tract, apex, and infundibulum. Ventricular aneurysms at these sites can be considered pathognomonic of ARVD. Another typical hallmark of ARVD is fibrofatty infiltration of the right ventricular free wall. These functional and morphologic characteristics are relevant to clinical imaging investigations such as contrast angiography, echocardiography, radionuclide angiography, ultrafast computed tomography, and magnetic resonance imaging (MRI). Among these techniques, MRI allows the clearest visualization of the heart, in particular because the right ventricle is involved, which is usually more difficult to explore with the other imaging modalities. Furthermore, MRI offers the specific advantage of visualizing adipose infiltration as a bright signal of the right ventricular myocardium. MRI provides the most important anatomic, functional, and morphologic criteria for diagnosis of ARVD within one single study. As a result, MRI appears to be the optimal imaging technique for detecting and following patients with clinical suspicion of ARVD. (orig.) [de

  19. Effect of implant position, angulation, and attachment height on peri-implant bone stress associated with mandibular two-implant overdentures: a finite element analysis.

    Science.gov (United States)

    Hong, Hae Ryong; Pae, Ahran; Kim, Yooseok; Paek, Janghyun; Kim, Hyeong-Seob; Kwon, Kung-Rock

    2012-01-01

    The aim of this study was to analyze and compare the level and distribution of peri-implant bone stresses associated with mandibular two-implant overdentures with different implant positions. Mathematical models of mandibles and overdentures were designed using finite element analysis software. Two intraosseous implants and ball attachment systems were placed in the interforaminal region. The overdenture, which was supported by the two implants, was designed to withstand bilateral and unilateral vertical masticatory loads (total 100 N). In all, eight types of models, which differed according to assigned implant positions, height of attachments, and angulation, were tested: MI (model with implants positioned in the lateral incisor sites), MC (implants in canine sites), MP (implants in premolar sites), MI-Hi (greater height of attachments), MC-M (canine implants placed with mesial inclination), MC-D (canine implants placed with distal inclination), MC-B (canine implants placed with buccal inclination), and MC-L (canine implants placed with lingual inclination). Peri-implant bone stress levels associated with overdentures retained by lateral incisor implants resulted in the lowest stress levels and the highest efficiency in distributing peri-implant stress. MI-Hi showed increased stress levels and decreased efficiency in stress distribution. As the implants were inclined, stress levels increased and the efficiency of stress distribution decreased. Among the inclined models, MC-B showed the lowest stress level and best efficiency in stress distribution. The lowest stress and the best stability of implants in mandibular two-implant overdentures were obtained when implants were inserted in lateral incisor areas with shorter attachments and were placed parallel to the long axes of the teeth.

  20. Is exercise training safe and beneficial in patients receiving left ventricular assist device therapy?

    Science.gov (United States)

    Alsara, Osama; Perez-Terzic, Carmen; Squires, Ray W; Dandamudi, Sanjay; Miranda, William R; Park, Soon J; Thomas, Randal J

    2014-01-01

    Because a limited number of patients receive heart transplantation, alternative therapies, such as left ventricular assist device (LVAD) therapy, have emerged. Published studies have shown that LVAD implantation, by itself, improves exercise tolerance to the point where it is comparable to those with mild heart failure. The improvement in exercise capacity is maximally achieved 12 weeks after LVAD therapy and can continue even after explantation of the device. This effect varies, depending on the type of LVAD and exercise training. The available data in the literature on safety and benefits of exercise training in patients after LVAD implantation are limited, but the data that are available suggest that training trends to be safe and have an impact on exercise capacity in LVAD patients. Although no studies were identified on the role of cardiac rehabilitation programs in the management of LVAD patients, it appears that cardiac rehabilitation programs offer an ideal setting for the provision of supervised exercise training in this patient group.