WorldWideScience

Sample records for totally implantable central

  1. A Comparison of Clinical Outcomes with Regular- and Low-Profile Totally Implanted Central Venous Port Systems

    International Nuclear Information System (INIS)

    Teichgraeber, Ulf Karl-Martin; Steitparth, Florian; Cho, Chie Hee; Benter, Thomas; Gebauer, Bernhard

    2009-01-01

    The purpose of this study was to evaluate whether low-profile totally implanted central venous port systems can reduce the late complication of skin perforation. Forty patients (age, 57 ± 13 years; 22 females, 18 males) were randomized for the implantation of a low-profile port system, and another 40 patients (age, 61 ± 14 years; 24 females, 16 males) received a regular port system as control group. Indications for port catheter implantation were malignant disease requiring chemotherapy. All port implantations were performed in the angiography suite using sonographically guided central venous puncture and fluoroscopic guidance of the catheter placement. Procedure time, number of complications (procedure-related immediate, early, and late complications), and number of explantations were assessed. Follow-up was performed for 6 months. All port implantations were successfully completed in both study groups. There were two incidents of skin perforation observed in the control group. One skin perforation occurred 13 weeks and the other 16 weeks after port implantation (incidence, 5%) in patients with regular-profile port systems. Two infections were observed, one port infection in each study group. Both infections were characterized as catheter-related infections (infection rate: 0.15 catheter-related infections per 1000 catheter days). In conclusion, low-profile port systems can be placed as safely as traditional chest ports and reduce the risk of developing skin perforations, which occurs when the port system is too tight within the port pocket.

  2. Usefulness of Totally Implantable Central Venous Access Devices in Elderly Patients: A Retrospective Study.

    Science.gov (United States)

    Imaoka, Yuki; Kuranishi, Fumito; Ogawa, Yoshiteru

    2018-01-01

    The need for totally implantable central venous access devices (TICVADs) has increased with increased opportunities in the use of chemotherapy and parenteral nutrition. This study aimed to determine the outcomes of TICVAD implantation and use in patients aged ≥85 years. Between January 2010 and August 2016, 117 patients underwent TICVAD implantation and their records were retrospectively reviewed. Participants were divided into 2 groups (plus-85 and sub-85 groups). Fifty-five patients (47.0%) had solid organ cancer alone; 35 patients (29.9%) had cerebrovascular or cranial nerve disease. The average follow-up period was 201 (2-1,620) days. Major complications were identified in 6 (14.6%) plus-85 patients and 11 (14.5%) sub-85 patients (p = 0.9813). Catheter-related infections developed in 3 plus-85 (7.3%) and 4 sub-85 patients (5.3%; p = 0.6549). There were no significant group differences in hematoma, pneumothorax, occlusion, and removal rates. In plus-85 patients examined just before surgery and a month after surgery, increased rates of serum albumin and Onodera's prognostic nutritional index were observed in 48% (14/39) and 41% (12/39), respectively. The use of TICVADs in the plus-85 group resulted in effective outcomes. The results of this retrospective study support the wider use of TICVADs in patients aged ≥85 years. © 2018 S. Karger AG, Basel.

  3. ["Let me tell you about my little box": phenomenological study on the experience of living with a totally implantable central venous catheter].

    Science.gov (United States)

    Mutti, Carolina; Fumagalli, Anna; Monni, Pierina; Rancati, Stefania; Rosi, Ivana Maria

    2016-01-01

    . "Let me tell you about my little box": phenomenological study on the experience of living with a totally implantable central venous catheter. Many variables impact on the choice to implant a totally implantable long-term central venous catheter's (Port), in spite of its proven efficacy. The patients' perception is pivotal, and only few qualitative studies dig deep into patients' feelings and experiences. To understand if, and how, the Port affects the patient's life. Qualitative phenomenological study based on semi-structured interviews on a convenience sample of patients implanted a Port, selected in an oncohematology Day Hospital in Milan. The analysis was carried out by three researchers with a phenomenological method. Four main themes, and sub-themes, emerged from twenty interviews. Relief, both physical and psychological; the process of the choice of inserting the Port and the importance of thinking about its positioning since the beginning of the treatment course; the symbol- the device reminds of the disease and its removal is of utmost importance; the technology progresses- the need of trust in the health care personnel and in their competences. The Port improved the patients' quality of life. The study allows some reflections on the need of considering the actual and future conditions of the patient to make a shared and informed choice.

  4. Efficacies of 125I seed implantation in advanced stage central lung cancer via fibrobronchoscope

    International Nuclear Information System (INIS)

    Liu Jianguo; An Liqing; Cheng Jinguang; Zhang Yufen; Guo Xiaokui

    2009-01-01

    Objective: To explore the temporal curative effect of 125 I seed implantation in advanced stage central type lung cancer. Methods: 125 I seed was implanted in 56 patients confirmed advanced stage central type lung cancer via fibrobronchoscope and all cases were fellow up in certain duration to explore their efficacies and the adverse reaction. Results: Total efficient rate was 76.78% in 56 patients. Lung reexpanded rate was 90.90%. Conclusion: The therapy of 125 I seed implantation in advanced stage central type lung cancer is safe and available. (authors)

  5. Total Artificial Heart Implantation Blood Pressure Management as Resolving Treatment for Massive Hemolysis following Total Artificial Heart Implantation.

    Science.gov (United States)

    Ghodsizad, Ali; Koerner, Michael M; El-Banayosy, A; Zeriouh, Mohamed; Ruhparwar, Arjang; Loebe, Matthias

    2016-10-21

    The SynCardia Total Artificial Heart (TAH) has been used for patients with biventricular failure, who cannot be managed with implantation of a left ventricular (LV) assist device. Following TAH implantation, our patient developed severe hemolysis, which could only be managed successfully by aggressive blood pressure control [Ohashi 2003; Nakata 1998].

  6. Surgeons' Perspectives on Premium Implants in Total Joint Arthroplasty.

    Science.gov (United States)

    Wasterlain, Amy S; Bello, Ricardo J; Vigdorchik, Jonathan; Schwarzkopf, Ran; Long, William J

    2017-09-01

    Declining total joint arthroplasty reimbursement and rising implant prices have led many hospitals to restrict access to newer, more expensive total joint arthroplasty implants. The authors sought to understand arthroplasty surgeons' perspectives on implants regarding innovation, product launch, costs, and cost-containment strategies including surgeon gain-sharing and patient cost-sharing. Members of the International Congress for Joint Reconstruction were surveyed regarding attitudes about implant technology and costs. Descriptive and univariate analyses were performed. A total of 126 surgeons responded from all 5 regions of the United States. Although 76.9% believed new products advance technology in orthopedics, most (66.7%) supported informing patients that new implants lack long-term clinical data and restricting new implants to a small number of investigators prior to widespread market launch. The survey revealed that 66.7% would forgo gain-sharing incentives in exchange for more freedom to choose implants. Further, 76.9% believed that patients should be allowed to pay incremental costs for "premium" implants. Surgeons who believed that premium products advance orthopedic technology were more willing to forgo gain-sharing (P=.040). Surgeons with higher surgical volume (P=.007), those who believed implant companies should be allowed to charge more for new technology (Pnew implants with patients. Many surgeons support alternative payment models permitting surgeons and patients to retain implant selection autonomy. Most respondents prioritized patient beneficence and surgeon autonomy above personal financial gain. [Orthopedics. 2017; 40(5):e825-e830.]. Copyright 2017, SLACK Incorporated.

  7. Sobredentadura total superior implantosoportada Superior total overdenture on implants

    Directory of Open Access Journals (Sweden)

    Luis Orlando Rodríguez García

    2010-06-01

    Full Text Available Se presenta un caso de un paciente desdentado total superior, rehabilitado en la consulta de implantología de la Clínica "Pedro Ortiz" del municipio Habana del Este en Ciudad de La Habana, Cuba, en el año 2009, mediante prótesis sobre implantes osteointegrados, técnica que se ha incorporado a la práctica estomatológica en Cuba como alternativa al tratamiento convencional en los pacientes desdentados totales. Se siguió un protocolo que comprendió una fase quirúrgica, procedimiento con o sin realización de colgajo y carga precoz o inmediata. Se presenta un paciente masculino de 56 años de edad, que acudió a la consulta multidisciplinaria, preocupado, porque se le habían elaborado tres prótesis en los últimos dos años y ninguna reunía los requisitos de retención que él necesitaba para sentirse seguro y cómodo con las mismas. El resultado final fue la satisfacción total del paciente, con el mejoramiento de la calidad estética y funcional.This is the case of a total maxilla edentulous patient seen in consultation of the "Pedro Ortíz" Clinic Implant of Habana del Este municipality in 2009 and con rehabilitation by prosthesis over osteointegration implants added to stomatology practice in Cuba as an alternative to conventional treatment in patients totally edentulous. We follow a protocol including a surgery or surgical phase, technique without or with flap creation and early or immediate load. This is a male patient aged 56 came to our multidisciplinary consultation worried because he had three prostheses in last two years and any fulfilled the requirements of retention to feel safe and comfortable with prostheses. The final result was the total satisfaction of rehabilitated patient improving its aesthetic and functional quality.

  8. Pinch-off syndrome: transection of implantable central venous access device

    OpenAIRE

    Sugimoto, Takuya; Nagata, Hiroshi; Hayashi, Ken; Kano, Nobuyasu

    2012-01-01

    As the population of people with cancer increases so does the number of patients who take chemotherapy. Majority of them are administered parentally continuously. Implantable central venous catheter device is a good choice for those patients; however, severe complication would occur concerning the devices. Pinch-off syndrome is one of the most severe complications. The authors report a severe case of pinch-off syndrome. The patient with the implantable central venous device could not take che...

  9. Positional changes of maxillary central incisors following orthodontic treatment using single-crown implants as fixed reference markers.

    Science.gov (United States)

    Brahem, E B; Holm, B; Sonnesen, L; Worsaae, N; Gotfredsen, K

    2017-12-01

    This follow-up study (1) compares tooth displacement of central incisors in patients with and without pre-implant orthodontic treatment and (2) investigates whether sex, age, or orthodontic retention have an effect on tooth displacement after the insertion of single-crown implants. Fifty-seven patients - thirty-seven with (test group) and twenty without pre-implant orthodontic treatment (control group) - were rehabilitated with 89 single-crown implants in the upper maxilla. Clinical and radiographic data, clinical photographs, and dental casts were collected during baseline examinations after prosthetic rehabilitation and at the final follow-up examination at least 5 years later. A total of 114 dental casts were digitalized and aligned using a software program to measure changes in the positions of the central incisors. After a follow-up period of at least five years, 87% of the central incisors measured in the test group were displaced >0.25 mm vertically compared with 70% in the control group. Seventy-eight percent of the test group teeth had moved >0.25 mm horizontally compared with 55% in the control group. These differences were not significant, and there were no significant correlations with patient age or sex. The majority of patients had minor vertical (60%) or horizontal (67%) tooth displacement of the central incisors (0.25-0.75 mm) after a minimum follow-up period of 5 years. This study found no significant differences in tooth displacement comparing patients with and without pre-implant orthodontic treatment. No significant effect of sex, age, orthodontic retention, or implant location was observed on tooth displacement. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  10. Positional changes of maxillary central incisors following orthodontic treatment using single-crown implants as fixed reference markers

    DEFF Research Database (Denmark)

    Brahem Ben, Elissa; Holm, Bente; Sonnesen, L

    2017-01-01

    OBJECTIVES: This follow-up study (1) compares tooth displacement of central incisors in patients with and without pre-implant orthodontic treatment and (2) investigates whether sex, age, or orthodontic retention have an effect on tooth displacement after the insertion of single-crown implants...... during baseline examinations after prosthetic rehabilitation and at the final follow-up examination at least 5 years later. A total of 114 dental casts were digitalized and aligned using a software program to measure changes in the positions of the central incisors. RESULTS: After a follow-up period......, and there were no significant correlations with patient age or sex. CONCLUSION: The majority of patients had minor vertical (60%) or horizontal (67%) tooth displacement of the central incisors (0.25-0.75 mm) after a minimum follow-up period of 5 years. This study found no significant differences in tooth...

  11. Totally implantable venous catheters for chemotherapy: experience in 500 patients

    Directory of Open Access Journals (Sweden)

    Nelson Wolosker

    Full Text Available CONTEXT: Totally implantable devices are increasingly being utilized for chemotherapy treatment of oncological patients, although few studies have been done in our environment to analyze the results obtained from the implantation and utilization of such catheters. OBJECTIVE: To study the results obtained from the implantation of totally implantable catheters in patients submitted to chemotherapy. TYPE OF STUDY: Prospective. SETTING: Hospital do Câncer A.C. Camargo, São Paulo, Brazil. METHODS: 519 totally implantable catheters were placed in 500 patients submitted to chemotherapy, with preference for the use of the right external jugular vein. Evaluations were made of the early and late-stage complications and patient evolution until removal of the device, death or the end of the treatment. RESULTS: The prospective analysis showed an average duration of 353 days for the catheters. There were 427 (82.2% catheters with no complications. Among the early complications observed, there were 15 pathway hematomas, 8 cases of thrombophlebitis of the distal stump of the external jugular vein and one case of pocket infection. Among the late-stage complications observed, there were 43 infectious complications (0.23/1000 days of catheter use, 11 obstructions (0.06/1000 days of catheter use and 14 cases of deep vein thrombosis (0.07/1000 days of catheter use. Removal of 101 catheters was performed: 35 due to complications and 66 upon terminating the treatment. A total of 240 patients died while the catheter was functioning and 178 patients are still making use of the catheter. CONCLUSION: The low rate of complications obtained in this study confirms the safety and convenience of the use of totally implantable accesses in patients undergoing prolonged chemotherapy regimes.

  12. A case-control study to identify risk factors for totally implantable central venous port-related bloodstream infection.

    Science.gov (United States)

    Lee, Guk Jin; Hong, Sook Hee; Roh, Sang Young; Park, Sa Rah; Lee, Myung Ah; Chun, Hoo Geun; Hong, Young Seon; Kang, Jin Hyoung; Kim, Sang Il; Kim, Youn Jeong; Chun, Ho Jong; Oh, Jung Suk

    2014-07-01

    To date, the risk factors for central venous port-related bloodstream infection (CVPBSI) in solid cancer patients have not been fully elucidated. We conducted this study in order to determine the risk factors for CVP-BSI in patients with solid cancer. A total of 1,642 patients with solid cancer received an implantable central venous port for delivery of chemotherapy between October 2008 and December 2011 in a single center. CVP-BSI was diagnosed in 66 patients (4%). We selected a control group of 130 patients, who were individually matched with respect to age, sex, and catheter insertion time. CVP-BSI occurred most frequently between September and November (37.9%). The most common pathogen was gram-positive cocci (n=35, 53.0%), followed by fungus (n=14, 21.2%). Multivariate analysis identified monthly catheter-stay as a risk factor for CVP-BSI (p=0.000), however, its risk was lower in primary gastrointestinal cancer than in other cancer (p=0.002). Initial metastatic disease and long catheter-stay were statistically significant factors affecting catheter life span (p=0.005 and p=0.000). Results of multivariate analysis showed that recent transfusion was a risk factor for mortality in patients with CVP-BSI (p=0.047). In analysis of the results with respect to risk factors, prolonged catheter-stay should be avoided as much as possible. It is necessary to be cautious of CVP-BSI in metastatic solid cancer, especially non-gastrointestinal cancer. In addition, avoidance of unnecessary transfusion is essential in order to reduce the mortality of CVP-BSI. Finally, considering the fact that confounding factors may have affected the results, conduct of a well-designed prospective controlled study is warranted.

  13. The Effect of the Crystalline Lens on Central Vault After Implantable Collamer Lens Implantation.

    Science.gov (United States)

    Qi, Meng-Ying; Chen, Qian; Zeng, Qing-Yan

    2017-08-01

    To identify associations between crystalline lens-related factors and central vault after Implantable Collamer Lens (ICL) (Staar Surgical, Monrovia, CA) implantation. This retrospective clinical study included 320 eyes from 186 patients who underwent ICL implantation surgery. At 1 year after surgery, the central vault was measured using anterior segment optical coherence tomography. Preoperative anterior chamber depth, lens thickness, lens position (lens position = anterior chamber depth + 1/2 lens thickness), and vault were analyzed to investigate the effects of lens-related factors on postoperative vault. The mean vault was 513 ± 215 µm at 1 year after surgery. Vault was positively correlated with preoperative anterior chamber depth (r = 0.495, P lens position (r = 0.371, P lens thickness (r = -0.262, P lens position than eyes in the other two vault groups (which had vaults ≥ 250 µm) (P lens position less than 5.1 mm had greatly reduced vaults (P lens could have an important influence on postoperative vault. Eyes with a shallower anterior chamber and a forward lens position will have lower vaults. [J Refract Surg. 2017;33(8):519-523.]. Copyright 2017, SLACK Incorporated.

  14. Implantable central venous chemoport: camparision of results according to approach routes and methods

    International Nuclear Information System (INIS)

    Shin, Byung Suck; Ahn, Moon Sang

    2003-01-01

    To evaluate the results and complications of placement of implantable port according to approach routes and methods. Between April 2001 and October 2002, a total of 103 implantable chemoport was placed in 95 patients for chemotherapy using preconnected type (n=39) and attachable type (n=64). Puncture sites were left subclavian vein (n=35), right subclavian vein (n=5), left internal jugular vein (n=9), right internal jugular vein (n=54). We evaluated duration of catheterization days, complications according to approach routes and methods. Implantable chemoport was placed successfully in all cases. Duration of catheterization ranged from 8 to 554 days(mean 159, total 17,872 catheter days). Procedure related complications occurred transient pulmonary air embolism (n=1), small hematoma (n=1) and malposition in using preconnected type (n=2). Late complications occurred catheter migration (n=5), catheter malfunction (n=3), occlusion (n=1) and infection (n=11). Among them 15 chemoport was removed (14.5%). Catheter migration was occured via subclavian vein in all cases (13%, p=.008). Infection developed in 10.7% of patients(0.61 per 1000 catheter days). There were no catheter-related central vein thrombosis. Implantation of chemoport is a safe procedure. Choice of right internal jugular vein than subclavian vain vein for puncture site has less complications. And selection of attachable type of chemoport is convenient than preconnected type. Adequate care of chemoport is essential for long patency

  15. Poorer survival after a primary implant during revision total knee arthroplasty

    NARCIS (Netherlands)

    Meijer, Marrigje F.; Reininga, Inge H. F.; Boerboom, Alexander L.; Stevens, Martin; Bulstra, Sjoerd K.

    Revision total knee arthroplasty (rTKA) is a complex procedure. Depending on the degree of ligament and bone damage, either primary or revision implants are used. The purpose of this study was to compare survival rates of primary implants with revision implants when used during rTKA. A retrospective

  16. Pinch-off syndrome: transection of implantable central venous access device.

    Science.gov (United States)

    Sugimoto, Takuya; Nagata, Hiroshi; Hayashi, Ken; Kano, Nobuyasu

    2012-11-30

    As the population of people with cancer increases so does the number of patients who take chemotherapy. Majority of them are administered parentally continuously. Implantable central venous catheter device is a good choice for those patients; however, severe complication would occur concerning the devices. Pinch-off syndrome is one of the most severe complications. The authors report a severe case of pinch-off syndrome. The patient with the implantable central venous device could not take chemotherapy because the device occluded. Further examination revealed the transection of the catheter. The transected fragment of the catheter in the heart was successfully removed by using a loop snare placed through the right femoral vein.

  17. Risk factors for central line-associated bloodstream infection in pediatric oncology patients with a totally implantable venous access port: A cohort study.

    Science.gov (United States)

    Viana Taveira, Michelle Ribeiro; Lima, Luciana Santana; de Araújo, Cláudia Corrêa; de Mello, Maria Júlia Gonçalves

    2017-02-01

    Totally implantable venous access ports (TIVAPs) are used for prolonged central venous access, allowing the infusion of chemotherapy and other fluids and improving the quality of life of children with cancer. TIVAPs were developed to reduce the infection rates associated with central venous catheters; however, infectious events remain common and have not been fully investigated in pediatric oncology patients. A retrospective cohort was formed to investigate risk factors for central line-associated bloodstream infection (CLABSI) in pediatric cancer patients. Sociodemographic, clinical, and TIVAP insertion-related variables were evaluated, with the endpoint being the first CLABSI. A Kaplan-Meier analysis was performed to determine CLABSI-free catheter survival. Overall, 188 children were evaluated over 77,541 catheter days, with 94 being diagnosed with CLABSI (50%). Although coagulase-negative staphylococci were the pathogens most commonly isolated, Gram-negative microorganisms (46.8%) were also prevalent. In the multivariate analysis, factors that increased the risk for CLABSI were TIVAP insertion prior to chemotherapy (risk ratio [RR] = 1.56; P Risk factors for CLABSI in pediatric cancer patients with a TIVAP may be related to the severity of the child's condition at catheter insertion. Insertion of the catheter before chemotherapy and unfavorable conditions such as malnutrition and bone marrow aplasia can increase the risk of CLABSI. Protocols must be revised and surveillance increased over the first 10 weeks of treatment. © 2016 Wiley Periodicals, Inc.

  18. Total Artificial Heart Implantation After Undifferentiated High-Grade Sarcoma Excision.

    Science.gov (United States)

    Kremer, Jamila; Farag, Mina; Arif, Rawa; Brcic, Andreas; Sabashnikov, Anton; Schmack, Bastian; Popov, Aron-Frederik; Karck, Matthias; Dohmen, Pascal M; Ruhparwar, Arjang; Weymann, Alexander

    2016-11-02

    BACKGROUND Total artificial heart (TAH) implantation in patients with aggressive tumor infiltration of the heart can be challenging. CASE REPORT We report on a patient with a rare primary undifferentiated high-grade spindle cell sarcoma of the mitral valve and in the left atrium, first diagnosed in 2014. The referring center did a first resection in 2014. In the course of 17 months, computer tomography (CT) scan again showed massive invasion of the mitral valve and left atrium. Partial resection and mitral valve replacement was not an option. We did a subtotal heart excision with total artificial heart implantation. In this report we discuss complications, risk factors, and perioperative management of this patient. CONCLUSIONS Patients with aggressive tumors of the heart can be considered for TAH implantation.

  19. [Total cervical disk replacement--implant-specific approaches: keel implant (Prodisc-C intervertebral disk prosthesis)].

    Science.gov (United States)

    Korge, Andreas; Siepe, Christoph J; Heider, Franziska; Mayer, H Michael

    2010-11-01

    Dynamic intervertebral support of the cervical spine via an anterolateral approach using a modular artificial disk prosthesis with end-plate fixation by central keel fixation. Cervical median or mediolateral disk herniations, symptomatic cervical disk disease (SCDD) with anterior osseous, ligamentous and/or discogenic narrowing of the spinal canal. Cervical fractures, tumors, osteoporosis, arthrogenic neck pain, severe facet degeneration, increased segmental instability, ossification of posterior longitudinal ligament (OPLL), severe osteopenia, acute and chronic systemic, spinal or local infections, systemic and metabolic diseases, known implant allergy, pregnancy, severe adiposity (body mass index > 36 kg/m2), reduced patient compliance, alcohol abuse, drug abuse and dependency. Exposure of the anterior cervical spine using the minimally invasive anterolateral approach. Intervertebral fixation of retainer screws. Intervertebral diskectomy. Segmental distraction with vertebral body retainer and vertebral distractor. Removal of end-plate cartilage. Microscopically assisted decompression of spinal canal. Insertion of trial implant to determine appropriate implant size, height and position. After biplanar image intensifier control, drilling for keel preparation using drill guide and drill bit, keel-cut cleaner to remove bone material from the keel cut, radiologic control of depth of the keel cut using the corresponding position gauge. Implantation of original implant under lateral image intensifier control. Removal of implant inserter. Functional postoperative care and mobilization without external support, brace not used routinely, soft brace possible for 14 days due to postoperative pain syndromes. Implantation of 100 cervical Prodisc-C disk prostheses in 78 patients (average age 48 years) at a single center. Clinical and radiologic follow-up 24 months postoperatively. Significant improvement based on visual analog scale and Neck Disability Index. Radiologic

  20. Influence of implant position on clinical crown length and peri-implant soft tissue dimensions at implant-supported single crowns replacing maxillary central incisors

    DEFF Research Database (Denmark)

    Peng, Min; Fei, Wei; Hosseini, Mandana

    2013-01-01

    The aims of the present study were to evaluate the influence of implant position on clinical crown length and marginal soft tissue dimensions at implant-supported single crowns of maxillary central incisors, and to validate the papilla index score (PIS). Twenty-five patients, who had lost one of ...... abutments and did not necessarily result in an increased crown length. The distal implant papilla heightwas obviously shorter, althoughthe mesial papilla height was similar to thatof the healthy dentition.The papilla index score was tested to be a valid index for papilla fill....

  1. Moderate hypothermia technique for chronic implantation of a total artificial heart in calves.

    Science.gov (United States)

    Karimov, Jamshid H; Grady, Patrick; Sinkewich, Martin; Sunagawa, Gengo; Dessoffy, Raymond; Byram, Nicole; Moazami, Nader; Fukamachi, Kiyotaka

    2017-06-01

    The benefit of whole-body hypothermia in preventing ischemic injury during cardiac surgical operations is well documented. However, application of hypothermia during in vivo total artificial heart implantation has not become widespread because of limited understanding of the proper techniques and restrictions implied by constitutional and physiological characteristics specific to each animal model. Similarly, the literature on hypothermic set-up in total artificial heart implantation has also been limited. Herein we present our experience using hypothermia in bovine models implanted with the Cleveland Clinic continuous-flow total artificial heart.

  2. Total artificial heart implantation in a young Marfan syndrome patient.

    Science.gov (United States)

    Rao, Prashant; Keenan, Jack B; Rajab, Taufiek K; Kim, Samuel; Smith, Richard; Amabile, Orazio; Khalpey, Zain

    2018-03-01

    Cardiovascular complications represent the leading cause of morbidity and mortality in patients with Marfan syndrome. Here, we describe a unique case where a total artificial heart was implanted in a young Marfan syndrome woman. A 22-year-old postpartum African American female with Marfan syndrome developed multiple severe valve dysfunction and biventricular failure that was refractory to medical management. She previously had a Bentall procedure for Type A aortic dissection and repair of a Type B dissection. We implanted a total artificial heart with a good outcome. Total artificial heart is a durable option for severe biventricular failure and multiple valvular dysfunction as a bridge to transplant in a young patient with Marfan syndrome.

  3. Worldwide experience with a totally subcutaneous implantable defibrillator

    DEFF Research Database (Denmark)

    Lambiase, Pier D; Barr, Craig; Theuns, Dominic A M J

    2014-01-01

    AIMS: The totally subcutaneous implantable-defibrillator (S-ICD) is a new alternative to the conventional transvenous ICD system to minimize intravascular lead complications. There are limited data describing the long-term performance of the S-ICD. This paper presents the first large internationa...

  4. Subclavian Vein Versus Arm Vein for Totally Implantable Central Venous Port for Patients with Head and Neck Cancer: A Retrospective Comparative Analysis

    International Nuclear Information System (INIS)

    Akahane, Akio; Sone, Miyuki; Ehara, Shigeru; Kato, Kenichi; Tanaka, Ryoichi; Nakasato, Tatsuhiko

    2011-01-01

    Purpose: This study was designed to compare central venous ports (CVP) from two different routes of venous access―the subclavian vein and arm vein―in terms of safety for patients with head and neck cancer (HNC). Methods: Patients with HNC who underwent image-guided implantations of CVPs were retrospectively evaluated. All CVPs were implanted under local anesthesia. Primary outcome measurements were rates and types of adverse events (AEs). Secondary outcomes included technical success and rate and reason of CVP removal. Results: A total of 162 patients (subclavian port group, 47; arm port group, 115) were included in this study. Technical success was achieved in all patients. The median follow-up period was 94 (range, 1–891) days. Two patients in the subclavian port group experienced periprocedural complications. Postprocedural AEs were observed in 8.5 and 22.6% of the subclavian port and arm port group patients, respectively (P = 0.044). Phlebitis and system occlusions were observed only in the arm port group. The rate of infection was not significantly different between the two groups. The CVP was removed in 34 and 39.1% of the subclavian port and arm port patients, respectively. Conclusions: Both subclavian and arm CVPs are feasible in patients with HNC. AEs were more frequent in the arm port group; thus, the arm port is not recommended as the first choice for patients with HNC. However, further experience is needed to improve the placement technique and the maintenance of CVPs and a prospective analysis is warranted.

  5. Strategies for reducing implant costs in the revision total knee arthroplasty episode of care.

    Science.gov (United States)

    Elbuluk, Ameer M; Old, Andrew B; Bosco, Joseph A; Schwarzkopf, Ran; Iorio, Richard

    2017-12-01

    Implant price has been identified as a significant contributing factor to high costs associated with revision total knee arthroplasty (rTKA). The goal of this study is to analyze the cost of implants used in rTKAs and to compare this pricing with 2 alternative pricing models. Using our institutional database, we identified 52 patients from January 1, 2014 to December 31, 2014. Average cost of components for each case was calculated and compared to the total hospital cost for that admission. Costs for an all-component revision were then compared to a proposed "direct to hospital" (DTH) standardized pricing model and a fixed price revision option. Potential savings were calculated from these figures. On average, 28% of the total hospital cost was spent on implants for rTKA. The average cost for revision of all components was $13,640 and ranged from $3000 to $28,000. On average, this represented 32.7% of the total hospital cost. Direct to hospital implant pricing could potentially save approximately $7000 per rTKA, and the fixed pricing model could provide a further $1000 reduction per rTKA-potentially saving $8000 per case on implants alone. Alternative implant pricing models could help lower the total cost of rTKA, which would allow hospitals to achieve significant cost containment.

  6. Evaluation of the Necessity of Port Fixation in Central Venous Port Implantation

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sang Su; Kim, Hyung Pil [Inje University Pusan Paik Hospital, Busan (Korea, Republic of); Bae, Jae Ik; Won, Je Hwan [Ajou University School of Medicine, Suwon (Korea, Republic of)

    2010-06-15

    The technical success and complications were especially focused on and evaluated the need for fixation of a port under fluoroscopic guidance placement of the totally implantable central venous access ports for long term central venous access. Two hundred eighty nine consecutive patients (170 men, 119 women, mean age: 52-year-old) who underwent venous port implantation for the administration of chemotherapy were followed over a 1-month period. The procedures were performed in the angiographic suite by an interventional radiologist and all access was through the right jugular vein, except for the patients who had undergone a right mastectomy. The procedures were performed in the following order: 1) venous puncture, 2) making a pocket, 3) catheter tunneling, 4) port insertion, 5) catheter sizing, and 6) insertion. A port which was connected to the tunneled catheter was inserted into the minimally sized subcutaneous pocket with the aid of a small retractor. A follow-up was performed with medical records and chest radiographs. The follow-up period for evaluating the venous port ranged from 59 to 329 days (mean: 175 days) The procedures performed to gain right jugular vein access were successful without difficulty in all cases. The 18 patients that underwent procedures to gain left jugular vein access encountered some difficulty upon insertion of a catheter into the SVC due to encountering the tortuous left brachiocephalic vein. No complications occurred during and immediately after the procedure. In one case the port chamber rotated within the subcutaneous pocket; however, no catheter migration or malfunction occurred. If port insertion was followed by catheter insertion, the port chamber can be tightly implanted in the minimally sized pocket. This would avoid the need for fixation of the catheter to the port chamber leading into the pocket

  7. Higher complication risk of totally implantable venous access port systems in patients with advanced cancer - a single institution retrospective analysis.

    Science.gov (United States)

    Chang, Yi-Fang; Lo, An-Chi; Tsai, Chung-Hsin; Lee, Pei-Yi; Sun, Shen; Chang, Te-Hsin; Chen, Chien-Chuan; Chang, Yuan-Shin; Chen, Jen-Ruei

    2013-02-01

    Totally implantable port systems are generally recommended for prolonged central venous access in diverse settings, but their risk of complications remains unclear for patients with advanced cancer. The aim of this study was to assess the risk of port system failure in patients with advanced cancer. We conducted a retrospective cohort study in a comprehensive cancer centre. A detailed chart review was conducted among 566 patients with 573 ports inserted during January-June, 2009 (average 345.3 catheter-days). Cox regression analysis was applied to evaluate factors during insertion and early maintenance that could lead to premature removal of the port systems due to infection or occlusion. Port system-related infection was significantly associated with receiving palliative care immediately after implantation (hazard ratio, HR = 7.3, 95% confidence interval, 95% CI = 1.2-46.0), after adjusting for probable confounders. Primary cancer site also impacted the occurrence of device-related infection. Receiving oncologic/palliative care (HR = 3.0, P = 0.064), advanced cancer stage (HR = 6.5, P = 0.077) and body surface area above 1.71 m(2) (HR = 3.4, P = 0.029) increased the risk of port system occlusion. Our study indicates that totally implantable port systems yield a higher risk of complications in terminally ill patients. Further investigation should be carefully conducted to compare outcomes of various central venous access devices in patients with advanced cancer and to develop preventive strategies against catheter failure.

  8. Age at implantation and auditory memory in cochlear implanted children.

    Science.gov (United States)

    Mikic, B; Miric, D; Nikolic-Mikic, M; Ostojic, S; Asanovic, M

    2014-05-01

    Early cochlear implantation, before the age of 3 years, provides the best outcome regarding listening, speech, cognition an memory due to maximal central nervous system plasticity. Intensive postoperative training improves not only auditory performance and language, but affects auditory memory as well. The aim of this study was to discover if the age at implantation affects auditory memory function in cochlear implanted children. A total of 50 cochlear implanted children aged 4 to 8 years were enrolled in this study: early implanted (1-3y) n = 27 and late implanted (4-6y) n = 23. Two types of memory tests were used: Immediate Verbal Memory Test and Forward and Backward Digit Span Test. Early implanted children performed better on both verbal and numeric tasks of auditory memory. The difference was statistically significant, especially on the complex tasks. Early cochlear implantation, before the age of 3 years, significantly improve auditory memory and contribute to better cognitive and education outcomes.

  9. Does the Implantation Technique for Totally Implantable Venous Access Ports (TIVAPs) Influence Long-Term Outcome?

    Science.gov (United States)

    Biacchi, Daniele; Sammartino, Paolo; Sibio, Simone; Accarpio, Fabio; Cardi, Maurizio; Sapienza, Paolo; De Cesare, Alessandro; Atta, Joseph Maher Fouad; Impagnatiello, Alessio; Di Giorgio, Angelo

    2016-02-01

    Totally implantable venous access ports (TIVAP) are eventually explanted for various reasons, related or unrelated to the implantation technique used. Having more information on long-term explantation would help improve placement techniques. From a series of 1572 cancer patients who had TIVAPs implanted in our center with the cutdown technique or Seldinger technique, we studied the 542 patients who returned to us to have their TIVAP explanted after 70 days or more. As outcome measures we distinguished between TIVAPs explanted for long-term complications (infection, catheter-, reservoir-, and patient-related complications) and TIVAPs no longer needed. Univariate and multivariate analyses were run to investigate the reasons for explantation and their possible correlation with implantation techniques. The most common reason for explantation was infection (47.6 %), followed by catheter-related (20.8 %), patient-related (14.7 %), and reservoir-related complications (4.7 %). In the remaining 12.2 % of cases, the TIVAP was explanted complication free after the planned treatments ended. Infection correlated closely with longer TIVAP use. Univariate and multivariate analyses identified the Seldinger technique as a major risk factor for venous thrombosis and catheter dislocation. The need for long-term TIVAP explantation in about one-third of cancer patients is related to the implantation techniques used.

  10. [A totally implantable venous access device. Implantation in general or local anaesthesia? A retrospective cost analysis].

    Science.gov (United States)

    Schuld, J; Richter, S; Moussavian, M R; Kollmar, O; Schilling, M K

    2009-08-01

    Implantation of venous access port systems can be performed in local or general anesthesia. In spite of the increasing rate of interventionally implanted systems, the surgical cut-down represents a safe alternative. Thus, the question arises whether--in context to the increasing health-economic pressure--open implantation in general anesthesia is still a feasible alternative to implantation in local anesthesia regarding OR efficiency and costs. In a retrospective analysis, 993 patients receiving a totally implantable venous access device between 2001 and 2007 were evaluated regarding OR utilization, turnover times, intraoperative data and costs. Implantations in local (LA) and general anesthesia (GA) were compared. GA was performed in 762 cases (76.6 %), LA was performed in 231 patients (23.3 %). Mean operation time was similar in both groups (LA 47.27 +/- 1.40 min vs. GA 45.41 +/- 0.75 min, p = 0.244). Patients receiving local anesthesia had a significantly shorter stay in the OR unit (LA 95.9 +/- 1.78 min vs. GA 105.92 +/- 0.92 min; p cut (LA 39.57 +/- 0.69 min vs. GA 50.46 +/- 0.52 min; p material costs were significantly lower in the LA group compared with the GA group (LA: 400.72 +/- 8.25 euro vs. GA: 482.86 +/- 6.23 euro; p systems in local anesthesia is superior in comparison to the implantation under general anesthesia regarding procedural times in the OR unit and costs. With the same operation duration, but less personnel and material expenditure, implantation in local anesthesia offers a potential economic advantage by permitting faster changing times. Implantation in GA only should be performed at a special request by the patient or in difficult venous conditions. Georg Thieme Verlag Stuttgart.New York.

  11. Evaluation of radioactive seeds implantation under PET-CT guidance for the treatment of central lung cancer with obstructive atelectasis

    International Nuclear Information System (INIS)

    Zhou Yi; Jiang Zhongpu; Wang Haiting; Zhang Yanjun; Jiang Qiang; Wang Jun; Ren Lijun; Xie Bin

    2010-01-01

    Objective: To evaluate percutaneous puncturing 125 I seed implantation by using PET-CT guided target localization technique in treating central lung cancer complicated by obstructive pulmonary atelectasis. Methods: A total of 30 patients with suspected central lung cancer complicated by obstructive pulmonary atelectasis on preoperative chest films were enrolled in this study. As no clear distinction existed between the tumor and the atelectatic consolidation shadow on plain chest films, CT scanning was carried out in all patients. If CT scan was still not able to determine the margin of the tumor, an additional PET-CT scanning was adopted. After ascertaining the location of the lung cancer, percutaneous puncturing implantation of 125 I seeds under PET-CT guidance was performed. The clinical data and the therapeutic results were evaluated. Results: A sharp distinction between the tumor and the atelectatic consolidation shadow was demonstrated on PET-CT scans in 21 cases. The mean volume of the targeted lesion reckoned from PET-CT scans was 26 cm 3 , and the 125 I seeds were implanted. The mean volume of the targeted lesion calculated on CT scans was 37 cm 3 . Six months after the treatment, the follow-up CT exam showed that the effective rate was 93% (28/30). The one-year survival rate was 100% . The complications included pneumothorax (n = 8), small amount of hemoptysis (n = 12) and fever (n = 2). No displacement or immigration of the implanted seeds occurred. Conclusion: PET-CT scanning is far superior to conventional CT scanning in determining the target area of the tumor in patients with central lung cancer complicated by obstructive pulmonary atelectasis. (authors)

  12. Total dose hardening of buried insulator in implanted silicon-on-insulator structures

    International Nuclear Information System (INIS)

    Mao, B.Y.; Chen, C.E.; Pollack, G.; Hughes, H.L.; Davis, G.E.

    1987-01-01

    Total dose characteristics of the buried insulator in implanted silicon-on-insulator (SOI) substrates have been studied using MOS transistors. The threshold voltage shift of the parasitic back channel transistor, which is controlled by charge trapping in the buried insulator, is reduced by lowering the oxygen dose as well as by an additional nitrogen implant, without degrading the front channel transistor characteristics. The improvements in the radiation characteristics of the buried insulator are attributed to the decrease in the buried oxide thickness or to the presence of the interfacial oxynitride layer formed by the oxygen and nitrogen implants

  13. Complications of Central Venous Totally Implantable Access Port: Internal Jugular Versus Subclavian Access

    Directory of Open Access Journals (Sweden)

    Pil Young Jung

    Full Text Available Background: Totally implantable access port (TIAP provides reliable, long term vascular access with minimal risk of infection and allows patients normal physical activity. With wide use of ports, new complications have been encountered. We analyzed TIAP related complications and evaluated the outcomes of two different percutaneous routes of access to superior vena cava. Methods: All 172 patients who underwent port insertion with internal jugular approach (Group 1, n = 92 and subclavian approach (Group 2, n = 79 between August 2011 and May 2013 in a single center were analyzed, retrospectively. Medical records were analyzed to compare the outcomes and the occurrence of port related complications between two different percutaneous routes of access to superior vena cava. Results: Median follow-up for TIAP was 278 days (range, 1-1868. Twenty four complications were occurred (14.0%, including pneumothorax (n = 1, 0.6%, migration/malposition (n = 4, 2.3%, pinch-off syndrome (n = 4, 2.3%, malfunction (n = 2, 1.1%, infection (n = 8, 4.7%, and venous thrombosis (n = 5, 2.9%. The overall incidence was 8.7% and 20.3% in each group (p = 0.030. Mechanical complications except infectious and thrombotic complications were more often occurred in group 2 (p = 0.033. The mechanical complication free probability is significantly higher in group 1 (p = 0.040. Conclusions: We suggest that the jugular access should be chosen in patients who need long term catheterization because of high incidence of mechanical complication, such as pinch-off syndrome.

  14. Experience with the once-yearly histrelin (GnRHa subcutaneous implant in the treatment of central precocious puberty

    Directory of Open Access Journals (Sweden)

    Katherine A Lewis

    2008-12-01

    Full Text Available Katherine A Lewis, Erica A EugsterDepartment of Pediatrics, Indiana University School of Medicine, Riley Hospital for Children, Indianapolis, USAAbstract: In 2007, a hydrogel histrelin implant was approved for the treatment of children with central precocious puberty (CPP. Children with CPP commonly have reduced height potential due to premature closure of the epiphyseal growth plates from exposure to sex steroids. Gonadotropin-releasing hormone analog (GnRHa treatment halts puberty and allows for improvement of adult height. A hydrogel implant delivery system utilizing the potent GnRHa, histrelin, was first developed for use in men with prostate cancer. A once yearly histrelin subcutaneous implant was subsequently developed for the treatment of children with CPP. Studies to date have demonstrated safety, tolerability, and effectiveness of this treatment option in patients treated up to 2 years. The most common adverse effects of the implant relate to implant site pain or bruising. Cost of this treatment seems comparable to somewhat higher than the commonly used GnRHa treatment option, depot leuprolide. While long term studies are needed to establish continued efficacy and safety beyond 2 years of treatment, the histrelin implant appears to be an attractive option for GnRHa treatment in patients with CPP.Keywords: central precocious puberty, histrelin, implant, gonadotropin-releasing-hormone analogs

  15. Accuracy of Implant Placement Utilizing Customized Patient Instrumentation in Total Knee Arthroplasty

    Directory of Open Access Journals (Sweden)

    William D. Bugbee

    2013-01-01

    Full Text Available Customized patient instrumentation (CPI combines preoperative planning with customized cutting jigs to position and align implants during total knee arthroplasty (TKA. We compared postoperative implant alignment of patients undergoing surgery with CPI to traditional TKA instrumentation for accuracy of implant placement. Twenty-five consecutive TKAs using CPI were analyzed. Preoperative CT scans of the lower extremities were segmented using a computer program. Limb alignment and mechanical axis were computed. Virtual implantation of computer-aided design models was done. Postoperative coronal and sagittal view radiographs were obtained. Using 3D image-matching software, relative positions of femoral and tibial implants were determined. Twenty-five TKAs implanted using traditional instrumentation were also analyzed. For CPI, difference in alignment from the preoperative plan was calculated. In the CPI group, the mean absolute difference between the planned and actual femoral placements was 0.67° in the coronal plane and 1.2° in the sagittal plane. For tibial alignment, the mean absolute difference was 0.9° in the coronal plane and 1.3° in the sagittal plane. For traditional instrumentation, difference from ideal placement for the femur was 1.5° in the coronal plane and 2.3° in the sagittal plane. For the tibia, the difference was 1.8° in the coronal plane. CPI achieved accurate implant positioning and was superior to traditional TKA instrumentation.

  16. Relation between total shock energy and mortality in patients with implantable cardioverter-defibrillator.

    Science.gov (United States)

    Tenma, Taro; Yokoshiki, Hisashi; Mitsuyama, Hirofumi; Watanabe, Masaya; Mizukami, Kazuya; Kamada, Rui; Takahashi, Masayuki; Sasaki, Ryo; Maeno, Motoki; Okamoto, Kaori; Chiba, Yuki; Anzai, Toshihisa

    2018-05-15

    Implantable Cardioverter-Defibrillator (ICD) shocks have been associated with mortality. However, no study has examined the relation between total shock energy and mortality. The aim of this study is to assess the association of total shock energy with mortality, and to determine the patients who are at risk of this association. Data from 316 consecutive patients who underwent initial ICD implantation in our hospital between 2000 and 2011 were retrospectively studied. We collected shock energy for 3 years from the ICD implantation, and determined the relation of shock energy on mortality after adjusting confounding factors. Eighty-seven ICD recipients experienced shock(s) within 3 years from ICD implantation and 43 patients had died during the follow-up. The amount of shock energy was significantly associated with all-cause death [adjusted hazard ratio (HR) 1.26 (per 100 joule increase), p energy accumulation (≥182 joule) was lower (p energy accumulation (energy accumulation and all-cause death was remarkable in the patients with low left ventricular ejection fraction (LVEF ≤40%) or atrial fibrillation (AF). Increase of shock energy was related to mortality in ICD recipients. This relation was evident in patients with low LVEF or AF. Copyright © 2018 Elsevier B.V. All rights reserved.

  17. The Cost-Effectiveness of Dual Mobility Implants for Primary Total Hip Arthroplasty: A Computer-Based Cost-Utility Model.

    Science.gov (United States)

    Barlow, Brian T; McLawhorn, Alexander S; Westrich, Geoffrey H

    2017-05-03

    Dislocation remains a clinically important problem following primary total hip arthroplasty, and it is a common reason for revision total hip arthroplasty. Dual mobility (DM) implants decrease the risk of dislocation but can be more expensive than conventional implants and have idiosyncratic failure mechanisms. The purpose of this study was to investigate the cost-effectiveness of DM implants compared with conventional bearings for primary total hip arthroplasty. Markov model analysis was conducted from the societal perspective with use of direct and indirect costs. Costs, expressed in 2013 U.S. dollars, were derived from the literature, the National Inpatient Sample, and the Centers for Medicare & Medicaid Services. Effectiveness was expressed in quality-adjusted life years (QALYs). The model was populated with health state utilities and state transition probabilities derived from previously published literature. The analysis was performed for a patient's lifetime, and costs and effectiveness were discounted at 3% annually. The principal outcome was the incremental cost-effectiveness ratio (ICER), with a willingness-to-pay threshold of $100,000/QALY. Sensitivity analyses were performed to explore relevant uncertainty. In the base case, DM total hip arthroplasty showed absolute dominance over conventional total hip arthroplasty, with lower accrued costs ($39,008 versus $40,031 U.S. dollars) and higher accrued utility (13.18 versus 13.13 QALYs) indicating cost-savings. DM total hip arthroplasty ceased being cost-saving when its implant costs exceeded those of conventional total hip arthroplasty by $1,023, and the cost-effectiveness threshold for DM implants was $5,287 greater than that for conventional implants. DM was not cost-effective when the annualized incremental probability of revision from any unforeseen failure mechanism or mechanisms exceeded 0.29%. The probability of intraprosthetic dislocation exerted the most influence on model results. This model

  18. Reverse Engineering Nature to Design Biomimetic Total Knee Implants.

    Science.gov (United States)

    Varadarajan, Kartik Mangudi; Zumbrunn, Thomas; Rubash, Harry E; Malchau, Henrik; Muratoglu, Orhun K; Li, Guoan

    2015-10-01

    While contemporary total knee arthroplasty (TKA) provides tremendous clinical benefits, the normal feel and function of the knee is not fully restored. To address this, a novel design process was developed to reverse engineer "biomimetic" articular surfaces that are compatible with normal soft-tissue envelope and kinematics of the knee. The biomimetic articular surface is created by moving the TKA femoral component along in vivo kinematics of normal knees and carving out the tibial articular surface from a rectangular tibial block. Here, we describe the biomimetic design process. In addition, we utilize geometric comparisons and kinematic simulations to show that; (1) tibial articular surfaces of conventional implants are fundamentally incompatible with normal knee motion, and (2) the anatomic geometry of the biomimetic surface contributes directly to restoration of normal knee kinematics. Such biomimetic implants may enable us to achieve the long sought after goal of a "normal" knee post-TKA surgery. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  19. Deairing Techniques for Double-Ended Centrifugal Total Artificial Heart Implantation.

    Science.gov (United States)

    Karimov, Jamshid H; Horvath, David J; Byram, Nicole; Sunagawa, Gengo; Grady, Patrick; Sinkewich, Martin; Moazami, Nader; Sale, Shiva; Golding, Leonard A R; Fukamachi, Kiyotaka

    2017-06-01

    The unique device architecture of the Cleveland Clinic continuous-flow total artificial heart (CFTAH) requires dedicated and specific air-removal techniques during device implantation in vivo. These procedures comprise special surgical techniques and intraoperative manipulations, as well as engineering design changes and optimizations to the device itself. The current study evaluated the optimal air-removal techniques during the Cleveland Clinic double-ended centrifugal CFTAH in vivo implants (n = 17). Techniques and pump design iterations consisted of developing a priming method for the device and the use of built-in deairing ports in the early cases (n = 5). In the remaining cases (n = 12), deairing ports were not used. Dedicated air-removal ports were not considered an essential design requirement, and such ports may represent an additional risk for pump thrombosis. Careful passive deairing was found to be an effective measure with a centrifugal pump of this design. In this report, the techniques and design changes that were made during this CFTAH development program to enable effective residual air removal and prevention of air embolism during in vivo device implantation are explained. © 2016 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  20. Feasibility and Safety of Endovascular Stripping of Totally Implantable Venous Access Devices

    International Nuclear Information System (INIS)

    Heye, Sam; Maleux, Geert; Goossens, G. A.; Vaninbroukx, Johan; Jerôme, M.; Stas, M.

    2012-01-01

    Purpose: To evaluate the safety and feasibility of percutaneous stripping of totally implantable venous access devices (TIVAD) in case of catheter-related sleeve and to report a technique to free the catheter tip from vessel wall adherence. Materials and Methods: A total of 37 stripping procedures in 35 patients (14 men, 40%, and 21 women, 60%, mean age 53 ± 14 years) were reviewed. Totally implantable venous access devices were implanted because of malignancy in most cases (85.7%). Catheter-related sleeve was confirmed as cause of persistent catheter dysfunction despite instillation of thrombolytics. A technique to mobilize the catheter tip from the vessel wall was used when stripping with the snare catheter was impossible. Technical success, complication rate, and outcome were noted. Results: A total of 55.9% (n = 19) of the 34 technically successful procedures (91.9%) could be done with the snare catheter. In 15 cases (44.1%), additional maneuvers to free the TIVAD’s tip from the vessel wall were needed. Success rate was not significantly lower before (72.4%) than after (96.7%) implementation of the new technique (P = 0.09). No complications were observed. Follow-up was available in 67.6% of cases. Recurrent catheter dysfunction was found in 17 TIVADs (78.3%) at a mean of 137.7 days and a median of 105 days. Conclusions: Stripping of TIVADs is technically feasible and safe, with an overall success rate of 91.9%. Additional endovascular techniques to mobilize the distal catheter tip from the wall of the superior vena cava or right atrium to allow encircling the TIVAD tip with the snare catheter may be needed in 44.1% of cases.

  1. Failure of total hip implants: metals and metal release in 52 cases

    DEFF Research Database (Denmark)

    Jakobsen, Stig Storgaard; Lidén, Carola; Søballe, Kjeld

    2014-01-01

    Background . The pathogenesis of total joint replacement failure is multifactorial. One hypothesis suggests that corrosion and wear of alloys result in metal ion release, which may then cause sensitization and even implant failure, owing to the acquired immune reactivity. Objectives . To assess c...

  2. Central moments of ion implantation distributions derived by the backward Boltzmann transport equation compared with Monte Carlo simulations

    International Nuclear Information System (INIS)

    Bowyer, M.D.J.; Ashworth, D.G.; Oven, R.

    1992-01-01

    In this paper we study solutions to the backward Boltzmann transport equation (BBTE) specialized to equations governing moments of the distribution of ions implanted into amorphous targets. A central moment integral equation set has been derived starting from the classical plane source BBTE for non-central moments. A full generator equation is provided to allow construction of equation sets of an arbitrary size, thus allowing computation of moments of arbitrary order. A BBTE solver program has been written that uses the residual correction technique proposed by Winterbon. A simple means is presented to allow direct incorporation of Biersack's two-parameter ''magic formula'' into a BBTE solver program. Results for non-central and central moment integral equation sets are compared with Monte Carlo simulations, using three different formulae for the mean free flight path between collisions. Comparisons are performed for the ions B and As, implanted into the target a-Si, over the energy range 1 keV-1 MeV. The central moment integral equation set is found to have superior convergence properties to the non-central moment equation set. For As ions implanted into a-Si, at energies below ∼ 30 keV, significant differences are observed, for third- and fourth-order moments, when using alternative versions for the mean free flight path. Third- and fourth-order moments derived using one- and two-parameter scattering mechanisms also show significant differences over the same energy range. (Author)

  3. Centrality of collisions and total disintegration of nuclei

    International Nuclear Information System (INIS)

    Sulejmanov, M.K.; Abdinov, O.B.; Anoshin, A.I.; Bogdanowicz, J.; Kuznetsov, A.A.

    1998-01-01

    The interrelation of the processes of total disintegration of nuclei with the process, characterized by the 'centrality' of collisions and a minimum flow of energy of secondary particles emitted at a zero angle in pC, dC, 4 HeC and 12 CC interactions, is investigated at 4.2 A · GeV/c. The events with total disintegration of nuclei are characterized by a high degree 'centrality' of collisions and similar to the events having a minimum flow of energy of particles emitted at a zero angle

  4. Complications after percutaneous placement of totally implantable venous access ports in the forearm

    International Nuclear Information System (INIS)

    Goltz, J.P.; Petritsch, B.; Thurner, A.; Hahn, D.; Kickuth, R.

    2012-01-01

    This article focuses on radiological imaging of complications after interventional percutaneous insertion of totally implantable venous access ports (TIVAPs) which were placed in the forearm. Thus far most reviews have dealt with pectorally-placed TIVAPs. Compared with the pectoral approach, implantation in the forearm has been associated with certain complications owing to a longer route of the port catheter within a smaller vein, and owing to the route across the elbow joint, resulting in higher rates of catheter-associated thrombosis and possible mechanical complications. The purpose of this review is to describe the complications after implantation of TIVAPs in the forearm, and to make radiologists familiar with the key findings of the complications during radiological imaging, including colour-coded and compression Duplex ultrasound, computed tomography, and digital subtraction venography.

  5. Choice of implant combinations in total hip replacement: systematic review and network meta-analysis.

    Science.gov (United States)

    López-López, José A; Humphriss, Rachel L; Beswick, Andrew D; Thom, Howard H Z; Hunt, Linda P; Burston, Amanda; Fawsitt, Christopher G; Hollingworth, William; Higgins, Julian P T; Welton, Nicky J; Blom, Ashley W; Marques, Elsa M R

    2017-11-02

    Objective  To compare the survival of different implant combinations for primary total hip replacement (THR). Design  Systematic review and network meta-analysis. Data sources  Medline, Embase, The Cochrane Library, ClinicalTrials.gov, WHO International Clinical Trials Registry Platform, and the EU Clinical Trials Register. Review methods  Published randomised controlled trials comparing different implant combinations. Implant combinations were defined by bearing surface materials (metal-on-polyethylene, ceramic-on-polyethylene, ceramic-on-ceramic, or metal-on-metal), head size (large ≥36 mm or small meta-analysis for revision. There was no evidence that the risk of revision surgery was reduced by other implant combinations compared with the reference implant combination. Although estimates are imprecise, metal-on-metal, small head, cemented implants (hazard ratio 4.4, 95% credible interval 1.6 to 16.6) and resurfacing (12.1, 2.1 to 120.3) increase the risk of revision at 0-2 years after primary THR compared with the reference implant combination. Similar results were observed for the 2-10 years period. 31 studies (2888 patients) were included in the analysis of Harris hip score. No implant combination had a better score than the reference implant combination. Conclusions  Newer implant combinations were not found to be better than the reference implant combination (metal-on-polyethylene (not highly cross linked), small head, cemented) in terms of risk of revision surgery or Harris hip score. Metal-on-metal, small head, cemented implants and resurfacing increased the risk of revision surgery compared with the reference implant combination. The results were consistent with observational evidence and were replicated in sensitivity analysis but were limited by poor reporting across studies. Systematic review registration  PROSPERO CRD42015019435. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence

  6. Current situation regarding central venous port implantation procedures and complications: a questionnaire-based survey of 11,693 implantations in Japan.

    Science.gov (United States)

    Shiono, Masatoshi; Takahashi, Shin; Takahashi, Masanobu; Yamaguchi, Takuhiro; Ishioka, Chikashi

    2016-12-01

    We conducted a nationwide questionnaire-based survey to understand the current situation regarding central venous port implantation in order to identify the ideal procedure. Questionnaire sheets concerning the number of implantation procedures and the incidence of complications for all procedures completed in 2012 were sent to 397 nationwide designated cancer care hospitals in Japan in June 2013. Venipuncture sites were categorized as chest, neck, upper arm, forearm, and others. Methods were categorized as landmark, cut-down, ultrasound-mark, real-time ultrasound guided, venography, and other groups. We received 374 responses (11,693 procedures) from 153 centers (38.5 %). The overall complication rates were 7.4 % for the chest (598/8,097 cases); 6.8 % for the neck (157/2325); 5.2 % for the upper arm (54/1,033); 7.3 % for the forearm (9/124); and 6.1 % for the other groups (7/114). Compared to the chest group, only the upper arm group showed a significantly lower incidence of complications (P = 0.010), and multivariate logistic regression (odds ratio 0.69; 95 % confidence interval 0.51-0.91; P = 0.008) also showed similar findings. Real-time ultrasound-guided puncture was most commonly used in the upper arm group (83.8 %), followed by the neck (69.8 %), forearm (53.2 %), chest (41.8 %), and other groups (34.2 %). Upper arm venipuncture with ultrasound guidance seems the most promising technique to prevent complications of central venous port implantation.

  7. EXPERIMENTAL RESEARCH OF REGENERATIVE FEATURES IN BONE TISSUES AROUND IMPLANTS AFTER ONE-STAGE BILATERAL TOTAL HIP REPLACEMENT

    Directory of Open Access Journals (Sweden)

    V. M. Mashkov

    2012-01-01

    Full Text Available Objective: to research the specific features of regenerative processes of bone tissue around implants after one-stage bilateral total hip replacement in experiment. Material and methods: 27 total hip replacement operations have been performed in 18 rabbits of breed "chinchilla" to which bipolar femoral endoprosthesis made of titanic alloy PT-38, one type-size, with friction pair metal-on-metal and neck-shaft angle 165 degrees have been implanted: total unilateral hip replacement operations have been performed in 9 animals (control group, one-stage bilateral total hip replacement operations have been performed in 9 animals (experimental group. During research they have been on radiological and clinical checking-up. After the experiment the animals had histological tests of the tissues around endoprosthesis components. Results and conclusions: After one-stage bilateral total hip replacement in early terms of research more expressed changes of bone tissue in the form of its thinning and decompaction were found around implants. One-stage bilateral total hip replacement did not essentially influence on the speed of osteogenesis around endoprothesis components in comparison with unilateral total hip replacement, so in late terms of observation in both groups the fixing of endoprothesis components did not differ.

  8. Electromagnetic Compatibility of Transcutaneous Energy Transmission Systemfor Totally Implantable Artificial Heart

    Science.gov (United States)

    Shiba, Kenji; Koshiji, Kohji

    Transcutaneous Energy Transmission (TET) is one way of providing the energy needed to power a totally implantable artificial heart (TIAH). In the present study, an externally coupled TET system was implanted in a prototype human phantom to evaluate emission and immunity. In the emission evaluation, measurements were conducted based on CISPR Pub.11 and VDE 0871 standards, while immunity tests were based on the standards of the IEC 61000-4 series. The magnetic field of the radiated emission was measured using a loop antenna. At 0.1[MHz], we found the greatest magnetic field of 47.8 [dBμA/m], somewhat less than CISPR’s upper limit of 54 [dBμA/m]. For the conducted emission, by installing a noise filter and ferrite beads in the input section of the DC-power supply, conducted emission could be kept within the allowable limits of CISPR Pub.11 and VDE 0871. Finally, the immunity tests against radiated and conducted emission, electrostatic discharge and voltage fluctuation proved that the prototype could withstand the maximum level of disturbance. These results confirmed that the TET system implanted in a human phantom could, through modification, meet the emission and immunity standards.

  9. Total Artificial Heart Implantation after Excision of Right Ventricular Angiosarcoma.

    Science.gov (United States)

    Bruckner, Brian A; Abu Saleh, Walid K; Al Jabbari, Odeaa; Copeland, Jack G; Estep, Jerry D; Loebe, Matthias; Reardon, Michael J

    2016-06-01

    Primary cardiac sarcomas, although rare, are aggressive and lethal, requiring thorough surgical resection and adjuvant chemotherapy for the best possible outcome. We report the case of a 32-year-old woman who underwent total artificial heart implantation for right-sided heart failure caused by right ventricular angiosarcoma. For the first several weeks in intensive care, the patient recovered uneventfully. However, a postoperative liver biopsy indicated hepatocellular injury consistent with preoperative chemotherapy. She developed continuing liver failure, from which she died despite good cardiac function.

  10. Unconstrained tripolar implants for primary total hip arthroplasty in patients at risk for dislocation.

    Science.gov (United States)

    Guyen, Olivier; Pibarot, Vincent; Vaz, Gualter; Chevillotte, Christophe; Carret, Jean-Paul; Bejui-Hugues, Jacques

    2007-09-01

    We performed a retrospective study on 167 primary total hip arthroplasty (THA) procedures in 163 patients at high risk for instability to assess the reliability of unconstrained tripolar implants (press-fit outer metal shell articulating a bipolar polyethylene component) in preventing dislocations. Eighty-four percent of the patients had at least 2 risk factors for dislocation. The mean follow-up length was 40.2 months. No dislocation was observed. Harris hip scores improved significantly. Six hips were revised, and no aseptic loosening of the cup was observed. The tripolar implant was extremely successful in achieving stability. However, because of the current lack of data documenting polyethylene wear at additional bearing, the routine use of tripolar implants in primary THA is discouraged and should be considered at the present time only for selected patients at high risk for dislocation and with limited activities.

  11. Median Sternotomy or Right Thoracotomy Techniques for Total Artificial Heart Implantation in Calves.

    Science.gov (United States)

    Karimov, Jamshid H; Moazami, Nader; Sunagawa, Gengo; Kobayashi, Mariko; Byram, Nicole; Sale, Shiva; Such, Kimberly A; Horvath, David J; Golding, Leonard A R; Fukamachi, Kiyotaka

    2016-10-01

    The choice of optimal operative access technique for mechanical circulatory support device implantation ensures successful postoperative outcomes. In this study, we retrospectively evaluated the median sternotomy and lateral thoracotomy incisions for placement of the Cleveland Clinic continuous-flow total artificial heart (CFTAH) in a bovine model. The CFTAH was implanted in 17 calves (Jersey calves; weight range, 77.0-93.9 kg) through a median sternotomy (n = 9) or right thoracotomy (n = 8) for elective chronic implantation periods of 14, 30, or 90 days. Similar preoperative preparation, surgical techniques, and postoperative care were employed. Implantation of the CFTAH was successfully performed in all cases. Both methods provided excellent surgical field visualization. After device connection, however, the median sternotomy approach provided better visualization of the anastomoses and surgical lines for hemostasis confirmation and repair due to easier device displacement, which is severely limited following right thoracotomy. All four animals sacrificed after completion of the planned durations (up to 90 days) were operated through full median sternotomy. Our data demonstrate that both approaches provide excellent initial field visualization. Full median sternotomy provides larger viewing angles at the anastomotic suture line after device connection to inflow and outflow ports. Copyright © 2015 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  12. Scapula fracture incidence in reverse total shoulder arthroplasty using screws above or below metaglene central cage: clinical and biomechanical outcomes.

    Science.gov (United States)

    Kennon, Justin C; Lu, Caroline; McGee-Lawrence, Meghan E; Crosby, Lynn A

    2017-06-01

    Reverse total shoulder arthroplasty (RTSA) is a viable treatment option for rotator cuff tear arthropathy but carries a complication risk of scapular fracture. We hypothesized that using screws above the central glenoid axis for metaglene fixation creates a stress riser contributing to increased scapula fracture incidence. Clinical type III scapular fracture incidence was determined with screw placement correlation: superior screw vs. screws placed exclusively below the glenoid midpoint. Cadaveric RTSA biomechanical modeling was employed to analyze scapular fractures. We reviewed 318 single-surgeon single-implant RTSAs with screw correlation to identify type III scapular fractures. Seventeen cadaveric scapula specimens were matched for bone mineral density, metaglenes implanted, and fixation with 2 screw configurations: inferior screws alone (group 1 INF ) vs. inferior screws with one additional superior screw (group 2 SUP ). Biomechanical load to failure was analyzed. Of 206 patients, 9 (4.4%) from the superior screw group experienced scapula fractures (type III); 0 fractures (0/112; 0%) were identified in the inferior screw group. Biomechanically, superior screw constructs (group 2 SUP ) demonstrated significantly (P < .05) lower load to failure (1077 N vs. 1970 N) compared with constructs with no superior screws (group 1 INF ). There was no significant age or bone mineral density discrepancy. Clinical scapular fracture incidence significantly decreased (P < .05) for patients with no screws placed above the central cage compared with patients with superior metaglene screws. Biomechanical modeling demonstrates significant construct compromise when screws are used above the central cage, fracturing at nearly half the ultimate load of the inferior screw constructs. We recommend use of inferior screws, all positioned below the central glenoid axis, unless necessary to stabilize the metaglene construct. Copyright © 2016 Journal of Shoulder and Elbow Surgery

  13. Peripherally Placed Totally Implantable Venous-access Port Systems of the Forearm: Clinical Experience in 763 Consecutive Patients

    International Nuclear Information System (INIS)

    Goltz, Jan P.; Scholl, Anne; Ritter, Christian O.; Wittenberg, Guenther; Hahn, Dietbert; Kickuth, Ralph

    2010-01-01

    The aim of this study is to evaluate the effectiveness and safety of percutaneously placed totally implantable venous-access ports (TIVAPs) of the forearm. Between January 2006 and October 2008, peripheral TIVAPs were implanted in 763 consecutive patients by ultrasound and fluoroscopic guidance. All catheters were implanted under local anesthesia and were tunneled subcutaneously. Indication, technical success, and complications were retrospectively analyzed according to Society of Interventional Radiology (SIR) criteria. Presence of antibiotic prophylaxis, periprocedurally administered drugs (e.g., sedation), and laboratory results at the time of implantation were analyzed. Maintenance during the service interval was evaluated. In total, 327,499 catheter-days were analyzed. Technical success rate was 99.3%. Reasons for initial failure of implantation were either unexpected thrombosis of the subclavian vein, expanding tumor mass of the mediastinum, or failure of peripheral venous access due to fragile vessels. Mean follow-up was 430 days. There were 115 complications observed (15.1%, 0.03 per 100 catheter-days), of which 33 (4.3%) were classified as early (within 30 days from implantation) and 82 (10.7%) as late. Catheter-related venous thrombosis was found in 65 (8.5%) of 763 (0.02 per 100 catheter-days) TIVAPs. Infections were observed in 41 (5.4%) of 763 (0.01 per 100 catheter-days) devices. Other complications observed included dislocation of the catheter tip (0.8%), occlusion (0.1%), or rupture (0.1%) of the port catheter. Dislocated catheters were corrected during a second interventional procedure. In conclusion, implantation of percutaneously placed peripheral TIVAPs shows a high technical success rate and low risk of early complications when ultrasound and fluoroscopic guidance are used. Late complications are observed three times as often as early complications.

  14. Patient - implant dimension mismatch in total knee arthroplasty: Is it worth worrying? An Indian scenario

    Directory of Open Access Journals (Sweden)

    Jai Thilak

    2016-01-01

    Full Text Available Background: The correct sizing of the components in both anteroposterior and mediolateral (ML dimensions is crucial for the success of a total knee arthroplasty (TKA. The size of the implants selected is based on the intraoperative measurements. The currently used TKA implants available to us are based on morphometric measurements obtained from a Western/Caucasian population. Hence, the risk of component ML mismatch is more common in Asian sub-population, as they are of a smaller built and stature. This study aims to look into the following aspects agnitude of the ML mismatch between the femoral component and the patient′s anatomical dimension, evaluation of gender variations in distal femur dimensions, and gender-wise and implant-wise correlation of ML mismatch. Materials and Methods: Intraoperatively, the distal femoral dimensions were measured using sterile calipers after removing the osteophytes and compared with the ML dimension of the implant used. ML mismatch length thus obtained is correlated with the various parameters. Results: Males showed larger distal femoral dimensions when compared to females. Males had larger ML mismatch. None of the implants used perfectly matched the patient′s anatomical dimensions. Patients with larger mismatch had lower scorings at 2 years postoperative followup. Conclusion: Implant manufacturers need to design more options of femoral implants for a better fit in our subset of patients. The exact magnitude of mismatch which can cause functional implications need to be made out. The mismatch being one of the important factors for the success of the surgery, we should focus more on this aspect.

  15. Metastatic spread from squamous cell carcinoma of the hypopharynx to the totally implantable venous access port insertion site: Case report and review of literature.

    Science.gov (United States)

    Mangla, Ankit; Agarwal, Nikki; Mullane, Michael Russell

    2017-12-01

    The totally implantable venous access port plays a crucial role in delivering chemotherapy in the outpatient setting. Here, we report the first case of a patient with hypopharyngeal tumor who developed chest wall metastasis over the totally implantable venous access port inserted in the internal jugular vein. Our patient, a 58-year-old man with a hypopharyngeal tumor presented with a lump over the totally implantable venous access port site. The port was removed and the lump was biopsied. The CT studies showed that the tumor had spread along the catheter from the hypopharynx to the chest wall. The pathology from the biopsy showed squamous cell carcinoma (SCC). The patient had poor performance status and opted for hospice care. We present a novel case of metastasis over the totally implantable venous access port implanted in a patient with a hypopharyngeal tumor. We also reviewed relevant literature comparing the data from percutaneous endoscopic gastrostomy (PEG) tube site metastasis with our patient and other similar case reports. © 2017 Wiley Periodicals, Inc.

  16. Scintigraphic examinations after stent implantation in central airways

    International Nuclear Information System (INIS)

    Richter, W.S.; Kettner, B.I.; Munz, D.L.

    1998-01-01

    Endotracheal and endobronchial stent implantation has been developed as an effective treatment of benign and malignant airway stenosis and of tracheo- or bronchoesophageal fistulas. The selection of the stent type depends on the kind and site of disease. Chest X-ray and bronchoscopy are the procedures of choice for monitoring of stent position, structure, and function. However, with scintigraphic methods the effects of stent implantation on pulmonary ventilation and perfusion can be assessed non-invasively. The validation of the effect of a stent implantation on mucociliary and tussive clearance remains to be elucidated. (orig.) [de

  17. Prototype Development of an Implantable Compliance Chamber for a Total Artificial Heart.

    Science.gov (United States)

    Schmitz, Stephanie; Unthan, Kristin; Sedlaczek, Marc; Wald, Felix; Finocchiaro, Thomas; Spiliopoulos, Sotirios; Koerfer, Reiner; Steinseifer, Ulrich

    2017-02-01

    At our institute a total artificial heart is being developed. It is directly actuated by a linear drive in between two ventricles, which comprise membranes to separate the drive and blood flow. A compliance chamber (CC) is needed to reduce pressure peaks in the ventricles and to increase the pump capacity. Therefore, the movement of the membrane is supported by applying a negative pressure to the air volume inside the drive unit. This study presents the development of the implantable CC which is connected to the drive unit of the total artificial hearts (TAH). The anatomical fit of the CC is optimized by analyzing CT data and adapting the outer shape to ensure a proper fit. The pressure peaks are reduced by the additional volume and the flexible membrane of the CC. The validation measurements of change in pressure peaks and flow are performed using the complete TAH system connected to a custom mock circulation loop. Using the CC, the pressure peaks could be damped below 5 mm Hg in the operational range. The flow output was increased by up to 14.8% on the systemic side and 18.2% on the pulmonary side. The described implantable device can be used for upcoming chronic animal trials. © 2016 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  18. Evaluation of anterior chest wall implanted port: technical aspects, results, and complications

    International Nuclear Information System (INIS)

    Jeon, Young Hwan; Oh, Joo Hyeong; Yoon, Yup; Kim, Si Young

    2000-01-01

    To evaluate the technical aspects, results and complications of patients with implanted anterior chest wall port. Between April 1997 and June 1999, a total of 63 implanted ports were placed at the anterior chest wall of 63 consecutive patients by interventional radiologists. The indications were chemotherapy in 61 patients and total parenteral nutrition in two. The peripheral portion of the subclavian vein was punctured under fluoroscopic guidance via ipsilateral peripheral vein during venography. A central venous catheter was placed in the superior vena cava, and using the subcutaneous tunneling method, a connected infusion port was implanted at the anterior chest wall. Results and complications were reviewed, and by means of Kaplan-Meier survival analysis, the expected patency of the port was determined. The technical success rate for implanted port at the anterior chest wall was 100% (63/63 patients). In two patients, hematoma and oozing were treated by compression. The duration of port implantation ranged from 12 to 855 (mean, 187) days, and the port patency rate was 305.7±47.6 days. In seven patients (completed chemotherapy (n=3D3), central venous thrombosis (n=3D3) catheter-related infection (n=3D1)), the port was removed. Catheter obstruction occurred in two patients, and in one, the use of urokinase led to successful recanalization. Sixteen patients died of an underlying malignancy, but no catheter-related death was noted. Implantation of an anterior chest wall port is a safe and useful procedure, with long patency, for patients requiring chemotherapy and long-term venous access. (author)

  19. Evaluation of anterior chest wall implanted port: technical aspects, results, and complications

    Energy Technology Data Exchange (ETDEWEB)

    Jeon, Young Hwan; Oh, Joo Hyeong; Yoon, Yup; Kim, Si Young [Kyung Hee University Hospital, Seoul (Korea, Republic of)

    2000-07-01

    To evaluate the technical aspects, results and complications of patients with implanted anterior chest wall port. Between April 1997 and June 1999, a total of 63 implanted ports were placed at the anterior chest wall of 63 consecutive patients by interventional radiologists. The indications were chemotherapy in 61 patients and total parenteral nutrition in two. The peripheral portion of the subclavian vein was punctured under fluoroscopic guidance via ipsilateral peripheral vein during venography. A central venous catheter was placed in the superior vena cava, and using the subcutaneous tunneling method, a connected infusion port was implanted at the anterior chest wall. Results and complications were reviewed, and by means of Kaplan-Meier survival analysis, the expected patency of the port was determined. The technical success rate for implanted port at the anterior chest wall was 100% (63/63 patients). In two patients, hematoma and oozing were treated by compression. The duration of port implantation ranged from 12 to 855 (mean, 187) days, and the port patency rate was 305.7{+-}47.6 days. In seven patients (completed chemotherapy (n=3D3), central venous thrombosis (n=3D3) catheter-related infection (n=3D1)), the port was removed. Catheter obstruction occurred in two patients, and in one, the use of urokinase led to successful recanalization. Sixteen patients died of an underlying malignancy, but no catheter-related death was noted. Implantation of an anterior chest wall port is a safe and useful procedure, with long patency, for patients requiring chemotherapy and long-term venous access. (author)

  20. Total artificial heart implantation for biventricular failure due to eosinophilic myocarditis.

    Science.gov (United States)

    Kawabori, Masashi; Kurihara, Chitaru; Miller, Yair; Heck, Kent A; Bogaev, Roberta C; Civitello, Andrew B; Cohn, William E; Frazier, O H; Morgan, Jeffrey A

    2017-09-01

    Idiopathic hypereosinophilic syndrome is a condition of unknown etiology characterized by proliferation of eosinophils and their infiltration into tissues. Although cardiac involvement is rare, eosinophilic myocarditis can lead to life-threating fulminant congestive heart failure. Treatment of patients with eosinophilic myocarditis is challenging as heart failure can be caused by biventricular dysfunction. To our knowledge, this is the first case reported in the literature describing a patient with acute severe biventricular heart failure caused by eosinophilic myocarditis with mural left ventricular apical thrombus who was successfully treated with implantation of a total artificial heart as a bridge to heart transplant.

  1. Braile vena cava filter and greenfield filter in terms of centralization.

    Science.gov (United States)

    de Godoy, José Maria Pereira; Menezes da Silva, Adinaldo A; Reis, Luis Fernando; Miquelin, Daniel; Torati, José Luis Simon

    2013-01-01

    The aim of this study was to evaluate complications experienced during implantation of the Braile Vena Cava filter (VCF) and the efficacy of the centralization mechanism of the filter. This retrospective cohort study evaluated all Braile Biomédica VCFs implanted from 2004 to 2009 in Hospital de Base Medicine School in São José do Rio Preto, Brazil. Of particular concern was the filter's symmetry during implantation and complications experienced during the procedure. All the angiographic examinations performed during the implantation of the filters were analyzed in respect to the following parameters: migration of the filter, non-opening or difficulties in the implantation and centralization of the filter. A total of 112 Braile CVFs were implanted and there were no reports of filter opening difficulties or in respect to migration. Asymmetry was observed in 1/112 (0.9%) cases. A statistically significant difference was seen on comparing historical data on decentralization of the Greenfield filter with the data of this study. The Braile Biomédico filter is an evolution of the Greenfield filter providing improved embolus capture and better implantation symmetry.

  2. Stresses generated by two zygomatic implant placement techniques associated with conventional inclined anterior implants

    Directory of Open Access Journals (Sweden)

    Paulo H.T. Almeida

    2018-06-01

    Full Text Available Purpose: To make a comparative evaluation, by means of the finite element method, of the stress generated on supporting tissues and prosthetic system components, using zygomatic implants with the exteriorized and extramaxillary techniques, and different placement positions, associated either with inclined anterior implants, or those without inclination. Materials and methods: Eight (8 tridimensional models were created to represent the clinical situations being researched, using the dataset of scanned images of an edentulous model. The implants and prosthetic components were photographed on millimeter paper and inserted into Rhinoceros 3D modeling computer software. From the measurements made on the image, the virtual models were made. The application force was distributed on the occlusal surface of the working side of the left maxillary first molar, first and second premolars, and incisal regions of the central incisor, simulating the occlusal load during mastication, in a total of 150 N. Results: The extramaxillary technique presented considerable variation in increased tension on the prosthesis screws and bone tissue. In the exteriorized technique, the highest tension values occurred in the region of the ridge, and the lowest, on the zygomatic process; the absence of cantilever reduced the stress on bone tissue in almost all regions. Conclusion: The exteriorized technique was shown to be more favorable to the distribution of stresses on the micro-unit screws and bone tissue, with the model with zygomatic implant placed in the region of the first molar and inclined anterior implant presenting the best results. Keywords: Zygomatic implants, Atrophic maxilla, Finite element analysis, Cantilever, Inclined implant

  3. System overview of the fully implantable destination therapy--ReinHeart-total artificial heart.

    Science.gov (United States)

    Pelletier, Benedikt; Spiliopoulos, Sotirios; Finocchiaro, Thomas; Graef, Felix; Kuipers, Kristin; Laumen, Marco; Guersoy, Dilek; Steinseifer, Ulrich; Koerfer, Reiner; Tenderich, Gero

    2015-01-01

    Owing to the lack of suitable allografts, the demand for long-term mechanical circulatory support in patients with biventricular end-stage heart failure is rising. Currently available Total Artificial Heart (TAH) systems consist of pump units with only limited durability, percutaneous tubes and bulky external equipment that limit the quality of life. Therefore we are focusing on the development of a fully implantable, highly durable destination therapy total artificial heart. The ReinHeart-TAH system consists of a passively filling pump unit driven by a low-wear linear drive between two artificial ventricles, an implantable control unit and a compliance chamber. The TAH is powered by a transcutaneous energy transmission system. The flow distribution inside the ventricles was analysed by fluid structure interaction simulation and particle image velocimetry measurements. Along with durability tests, the hydrodynamic performance and flow balance capability were evaluated in a mock circulation loop. Animal trials are ongoing. Based on fluid structure interaction simulation and particle image velocimetry, blood stagnation areas have been significantly reduced. In the mock circulation loop the ReinHeart-TAH generated a cardiac output of 5 l/min at an operating frequency of 120 bpm and an aortic pressure of 120/80 mmHg. The highly effective preload sensitivity of the passively filling ventricles allowed the sensorless integration of the Frank Starling mechanism. The ReinHeart-TAH effectively replaced the native heart's function in animals for up to 2 days. In vitro and in vivo testing showed a safe and effective function of the ReinHeart-TAH system. This has the potential to become an alternative to transplantation. However, before a first-in-man implant, chronic animal trials still have to be completed. © The Author 2014. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  4. Surgical implantation of intra-abdominal radiotransmitters in marine otters (Lontra felina) in central Chile.

    Science.gov (United States)

    Soto-Azat, Claudio; Boher, Francisca; Fabry, Mauricio; Pascual, Paulo; Medina-Vogel, Gonzalo

    2008-10-01

    Six free-ranging marine otters (Lontra felina) were livetrapped on the central coast of Chile and implanted with specially designed radiotransmitters as part of a spatial ecology study. Marine otters frequent the rocky seashore, often squeezing their narrow bodies through cracks and crevices and grooming themselves on the rocks. They are also among the smallest of the otter species, weighing between 3.4 kg and 4.5 kg. For these reasons, the transmitter used was small, rectangular, and flat, measuring 3.5 x 3.2 x 1.0 cm. They were implanted using a ventral midline approach to minimize contact between the skin incision and sharp-edged rocks. Surgical incisions healed within 2 wk. The transmitters functioned well, but the duration varied from 62 days to 143 days instead of the 240 days predicted by the manufacturer. All six marine otters reestablished in their home ranges, and survey results suggest they survived well beyond the life of the transmitters.

  5. Development of an acoustic measurement protocol to monitor acetabular implant fixation in cementless total hip Arthroplasty: A preliminary study.

    Science.gov (United States)

    Goossens, Quentin; Leuridan, Steven; Henyš, Petr; Roosen, Jorg; Pastrav, Leonard; Mulier, Michiel; Desmet, Wim; Denis, Kathleen; Vander Sloten, Jos

    2017-11-01

    In cementless total hip arthroplasty (THA), the initial stability is obtained by press-fitting the implant in the bone to allow osseointegration for a long term secondary stability. However, finding the insertion endpoint that corresponds to a proper initial stability is currently based on the tactile and auditory experiences of the orthopedic surgeon, which can be challenging. This study presents a novel real-time method based on acoustic signals to monitor the acetabular implant fixation in cementless total hip arthroplasty. Twelve acoustic in vitro experiments were performed on three types of bone models; a simple bone block model, an artificial pelvic model and a cadaveric model. A custom made beam was screwed onto the implant which functioned as a sound enhancer and insertor. At each insertion step an acoustic measurement was performed. A significant acoustic resonance frequency shift was observed during the insertion process for the different bone models; 250 Hz (35%, second bending mode) to 180 Hz (13%, fourth bending mode) for the artificial bone block models and 120 Hz (11%, eighth bending mode) for the artificial pelvis model. No significant frequency shift was observed during the cadaveric experiment due to a lack of implant fixation in this model. This novel diagnostic method shows the potential of using acoustic signals to monitor the implant seating during insertion. Copyright © 2017 IPEM. Published by Elsevier Ltd. All rights reserved.

  6. Research on total-dose hardening for H-gate PD NMOSFET/SIMOX by ion implanting into buried oxide

    International Nuclear Information System (INIS)

    Qian Cong; Zhang Zhengxuan; Zhang Feng; Lin Chenglu

    2008-01-01

    In this work, we investigate the back-gate I-V characteristics for two kinds of NMOSFET/SIMOX transistors with H gate structure fabricated on two different SOI wafers. A transistors are made on the wafer implanted with Si + and then annealed in N 2 , and B transistors are made on the wafer without implantation and annealing. It is demonstrated experimentally that A transistors have much less back-gate threshold voltage shift ΔV th than B transistors under X-ray total close irradiation. Subthreshold charge separation technique is employed to estimate the build-up of oxide charge and interface traps during irradiation, showing that the reduced ΔV th for A transistors is mainly due to its less build-up of oxide charge than B transistors. Photo-luminescence (PL) research indicates that Si implantation results in the formation of silicon nanocrystalline (nanocluster) whose size increases with the implant dose. This structure can trap electrons to compensate the positive charge build-up in the buried oxide during irradiation, and thus reduce the threshold voltage negative shift. (authors)

  7. Totally implantable central venous access port infections in patients with digestive cancer: incidence and risk factors.

    Science.gov (United States)

    Touré, Abdoulaye; Vanhems, Philippe; Lombard-Bohas, Catherine; Cassier, Philippe; Péré-Vergé, Denis; Souquet, Jean-Christophe; Ecochard, René; Chambrier, Cécile

    2012-12-01

    Central venous access port-related bloodstream infection (CVAP-BSI) is associated with morbidity and mortality in patients with cancer. This study examined the incidence rates and risk factors for CVAP-BSI in adult patients with digestive cancer. This prospective observational cohort study was performed from 2007 to 2011 in 2 oncology units of a university hospital. Incidence rate was expressed as number of CVAP-BSI per 1,000 catheter-days. A Cox regression model was used to identify risk factors for CVAP-BSI. A total of 315 patients were included. CVAP-BSI occurred in 41 patients (13.0%). The overall incidence rate was 0.76/1,000 catheter-days. The rate was higher in patients with esophageal cancer (1.28. P = .05) and pancreatic cancer (1.24; P = .007). Risk factors independently associated with CVAP-BSI were World Health Organization performance status between 2 and 4, catheter utilization-days in the previous month, pancreatic cancer, and parenteral nutrition. Coagulase-negative Staphylococci and enterobacteria were the main microorganisms isolated. In adult patients with digestive cancer, pancreatic cancer, cumulative catheter utilization-days, World Health Organization performance status, and parenteral nutrition were identified as independent risk factors for CVAP-BSI. Patients with any of these risk factors could be candidates for preventive strategies. Copyright © 2012 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Mosby, Inc. All rights reserved.

  8. Anatomy of the bovine ascending aorta and brachiocephalic artery found unfavorable for total artificial heart implant.

    Science.gov (United States)

    Karimov, Jamshid H; Sunagawa, Gengo; Such, Kimberly A; Sale, Shiva; Golding, Leonard A R; Moazami, Nader; Fukamachi, Kiyotaka

    2015-12-01

    The biocompatibility assessment of the Cleveland Clinic continuous-flow total artificial heart is an important part of the device developmental program. Surgical and postoperative management are key factors in achieving optimal outcomes. However, the presence of vascular anatomical abnormalities in experimental animal models is often unpredictable and may worsen the expected outcomes. We report a technical impediment encountered during total artificial heart implantation complicated by unfavorable bovine anatomy of the ascending aorta and brachiocephalic arterial trunk.

  9. Long latency auditory evoked potentials in children with cochlear implants: systematic review.

    Science.gov (United States)

    Silva, Liliane Aparecida Fagundes; Couto, Maria Inês Vieira; Matas, Carla Gentile; Carvalho, Ana Claudia Martinho de

    2013-11-25

    The aim of this study was to analyze the findings on Cortical Auditory Evoked Potentials in children with cochlear implant through a systematic literature review. After formulation of research question and search of studies in four data bases with the following descriptors: electrophysiology (eletrofisiologia), cochlear implantation (implante coclear), child (criança), neuronal plasticity (plasticidade neuronal) and audiology (audiologia), were selected articles (original and complete) published between 2002 and 2013 in Brazilian Portuguese or English. A total of 208 studies were found; however, only 13 contemplated the established criteria and were further analyzed; was made data extraction for analysis of methodology and content of the studies. The results described suggest rapid changes in P1 component of Cortical Auditory Evoked Potentials in children with cochlear implants. Although there are few studies on the theme, cochlear implant has been shown to produce effective changes in central auditory path ways especially in children implanted before 3 years and 6 months of age.

  10. Comparison of blood loss between using non central part cutting knee prosthesis and distal central part cutting.

    Science.gov (United States)

    Malairungsakul, Anan

    2014-12-01

    Patients who undergo knee replacement surgery may need to receive a blood transfusion due to blood loss during the operation. Therefore it was important to improve the design of knee implant operative procedures in an attempt to reduce the rate of blood loss. The present study aimed to compare the blood loss between two types of knee replacement surgery. This is a retrospective study in which 78 patients received cemented knee replacements in Phayao Hospital between October 2010 and March 2012. There were two types of surgical procedure: 1) using an implant position covering the end of the femoral bone without cutting into the central part of the distal femoral, 2) using an implant position covering the end of the femoral bone cutting the central part of the distal femoral. Blood loss, blood transfusion, hemoglobin and hematocrit were recorded preoperatively, immediately postsurgery and 48 hours after surgery. Findings revealed that the knee replacement surgery using the implant position covering the end of the femoral bone without cutting the central part of the distal femoral significantly lowered the rate of blood loss when compared to using the implant position covering the end of the femoral bone with central cutting of the distal femor. The average blood loss during the operation without cutting at the central part of distal femoral was 49.50 ± 11.11 mL; whereas the operation cutting the central part of the distal femoral was 58.50 ± 11.69 mL. As regards blood loss, the knee replacement surgery using the implant position covering the end ofthefemoral bone without cutting the central part of distal femor was better than using the implant position covering the end of the femoral bone cutting at the central part of the distal femor.

  11. Computer-navigated minimally invasive total knee arthroplasty for patients with retained implants in the femur

    Directory of Open Access Journals (Sweden)

    Sung-Yen Lin

    2014-08-01

    Full Text Available Total knee arthroplasty (TKA in patients with knee arthritis and retained implants in the ipsilateral femur is a challenge for knee surgeons. Use of a conventional intramedullary femoral cutting guide is not practical because of the obstruction of the medullary canal by implants. Previous studies have shown that computer-assisted surgery (CAS can help restore alignment in conventional TKA for patients with knee arthritis with retained femoral implants or extra-articular deformity, without the need for implant removal or osteotomy. However, little has been published regarding outcomes with the use of navigation in minimally invasive surgery (MIS-TKA for patients with this complex knee arthritis. MIS has been proven to provide less postoperative pain and faster recovery than conventional TKA, but MIS-TKA in patients with retained femoral implants poses a greater risk in limb malalignment. The purpose of this study is to report the outcome of CAS-MIS-TKA in patients with knee arthritis and retained femoral implants. Between April 2006 and March 2008, eight patients with knee arthritis and retained femoral implants who underwent the CAS-MIS-TKA were retrospectively reviewed. Three of the eight patients had extra-articular deformity, including two femur bones and one tibia bone, in the preoperative examination. The anteroposterior, lateral, and long-leg weight-bearing radiographs carried out at 3-month follow-up was used to determine the mechanical axis of lower limb and the position of components. The mean preoperative femorotibial angle in patients without extra-articular deformity was 3.8° of varus and was corrected to 4.6° of valgus. With the use of navigation in MIS-TKA, the two patients in this study with extra-articular femoral deformity also obtained an ideal postoperative mechanical axis within 2° of normal alignment. Overall, there was a good restoration of postoperative mechanical alignment in all cases, with a mean angle of 0.4° of

  12. Totally implantable vascular access device (TIVAD) placement: a modified technique that takes post-procedure aesthetic aspects into account.

    Science.gov (United States)

    Liberale, Gabriel

    2017-04-01

    Major progress has been made in breast cancer reconstruction surgery. The standard technique for totally implanted vascular access device (TIVAD) implantation generally requires an incision for port insertion on the anterior part of the thorax that leaves a scar in the middle of the neckline in patients who have undergone mastectomy with complex breast reconstruction. The aim of this technical note is to report our revised surgical technique for TIVAD placement. In patients with breast cancer, we take a lateralized approach, performing an oblique incision on the lowest part of the deltopectoral groove. This allows us to introduce the port and to place it on the anterolateral part of the thorax, thus avoiding an unaesthetic scar on the anterior part of the thorax. Our modified technique for TIVAD implantation is described.

  13. Immediate Implant Placement of a Single Central Incisor Using a CAD/CAM Crown-Root Form Technique: Provisional to Final Restoration.

    Science.gov (United States)

    Vafiadis, Dean; Goldstein, Gary; Garber, David; Lambrakos, Anthony; Kowalski, Bj

    2017-02-01

    Preserving soft and hard tissues after extraction and implant placement is crucial for anterior esthetics. This technique will show how the information gathered from a cone-beam computed tomography (CBCT) scan of the maxillary left central incisor and an intra-oral digital impression can be merged to fabricate a CAD/CAM crown-root matrix to be used as an immediate provisional restoration that mimics the natural anatomy. Due to trauma, a left central incisor appeared to be fractured and was scheduled for extraction and implant placement. The crown-root configuration captured by the CBCT scan was merged with the digital files from an intra-oral digital impression. A CAD/CAM crown-root matrix was fabricated. Because the matrix shell was fabricated with the exact anatomy of the natural tooth, it replicated the position and three dimensional anatomy of the soft and hard tissue. It was connected to the implant with a customized provisional abutment. A digital impression of a coded healing abutment was made to fabricate the final implant abutment and final restoration. Throughout the treatment time and 36 months after completion, the thickness of tissue, emergence profile, and adjacent papilla was analyzed by clinical evaluation and photography and seemed to be maintained. The use of a pre-operative intra-oral digital scan of the clinical crown-root architecture and the CBCT scan of the bone/root anatomy, can be used together to fabricate a CAD/CAM crown-root form provisional matrix. This digital design helps in the preservation of the 3D tissue topography, as well as the final restoration. The preservation of soft and hard tissue after extraction and implant placement has always been paramount for ideal anterior implant esthetics. Using the information from digital files from CBCT scans and intra-oral scans may help the clinician identify critical anatomical features that can be replicated in the provisional and final CAD/CAM restoration. (J Esthet Restor Dent 29

  14. [Total artificial heart].

    Science.gov (United States)

    Antretter, H; Dumfarth, J; Höfer, D

    2015-09-01

    To date the CardioWest™ total artificial heart is the only clinically available implantable biventricular mechanical replacement for irreversible cardiac failure. This article presents the indications, contraindications, implantation procedere and postoperative treatment. In addition to a overview of the applications of the total artificial heart this article gives a brief presentation of the two patients treated in our department with the CardioWest™. The clinical course, postoperative rehabilitation, device-related complications and control mechanisms are presented. The total artificial heart is a reliable implant for treating critically ill patients with irreversible cardiogenic shock. A bridge to transplantation is feasible with excellent results.

  15. Demikhov's "Mechanical Heart": The Circumstances Surrounding Creation of the World's First Implantable Total Artificial Heart in 1937.

    Science.gov (United States)

    Glyantsev, Sergey P; Tchantchaleishvili, Vakhtang; Bockeria, Leo A

    2016-01-01

    The world's first implantable total artificial heart was designed by Vladimir Demikhov as a fourth year biology student in Voronezh, Soviet Union, in 1937. As a prototype of his device, Demikhov must have used an apparatus for extracorporeal blood circulation invented by Sergei Bryukhonenko of Moscow. The device was the size of a dog's native heart and consisted of two diaphragm pumps brought into motion by an electric motor. A dog with an implanted device lived for 2.5 hours. In addition to having the prototype, the preconditions for Demikhov's artificial heart creation were his manual dexterity, expertise in animal physiology, and his mechanistic worldview.

  16. Incidence and risk factors for central venous access port-related infection in Chinese cancer patients

    Directory of Open Access Journals (Sweden)

    Ting-Yao Wang

    2015-11-01

    Conclusion: Infection remains to be a challenging issue for totally implantable central venous ports. Implementation of an insertion bundle for the prevention of central line-associated bloodstream infections is warranted, especially for those patients with hematological and head and neck cancers, as well as for patients receiving chemotherapy in the metastatic settings.

  17. Implant survival of the most common cemented total hip devices from the Nordic Arthroplasty Register Association database

    DEFF Research Database (Denmark)

    Junnila, Mika; Laaksonen, Inari; Eskelinen, Antti

    2016-01-01

    Background and purpose - According to previous Nordic Arthroplasty Register Association (NARA) data, the 10-year implant survival of cemented total hip arthroplasties (THAs) is 94% in patients aged 65-74 and 96% in patients aged 75 or more. Here we report a brand-level comparison of cemented THA...

  18. Does the number of implants have any relation with peri-implant disease?

    Directory of Open Access Journals (Sweden)

    Bernardo Born PASSONI

    2014-10-01

    Full Text Available Objective: The aim of this study was to evaluate the relationship between the number of pillar implants of implant-supported fixed prostheses and the prevalence of periimplant disease. Material and Methods: Clinical and radiographic data were obtained for the evaluation. The sample consisted of 32 patients with implant-supported fixed prostheses in function for at least one year. A total of 161 implants were evaluated. Two groups were formed according to the number of implants: G1 ≤5 implants and G2 >5 implants. Data collection included modified plaque index (MPi, bleeding on probing (BOP, probing depth (PD, width of keratinized mucosa (KM and radiographic bone loss (BL. Clinical and radiographic data were grouped for each implant in order to conduct the diagnosis of mucositis or peri-implantitis. Results: Clinical parameters were compared between groups using Student’s t test for numeric variables (KM, PD and BL and Mann-Whitney test for categorical variables (MPi and BOP. KM and BL showed statistically significant differences between both groups (p<0.001. Implants from G1 – 19 (20.43% – compared with G2 – 26 (38.24% – showed statistically significant differences regarding the prevalence of peri-implantitis (p=0.0210. Conclusion: It seems that more than 5 implants in total fixed rehabilitations increase bone loss and consequently the prevalence of implants with periimplantitis. Notwithstanding, the number of implants does not have any influence on the prevalence of mucositis.

  19. Influence of controlled immediate loading and implant design on peri-implant bone formation.

    Science.gov (United States)

    Vandamme, Katleen; Naert, Ignace; Geris, Liesbet; Vander Sloten, Jozef; Puers, Robert; Duyck, Joke

    2007-02-01

    Tissue formation at the implant interface is known to be sensitive to mechanical stimuli. The aim of the study was to compare the bone formation around immediately loaded versus unloaded implants in two different implant macro-designs. A repeated sampling bone chamber with a central implant was installed in the tibia of 10 rabbits. Highly controlled loading experiments were designed for a cylindrical (CL) and screw-shaped (SL) implant, while the unloaded screw-shaped (SU) implant served as a control. An F-statistic model with alpha=5% determined statistical significance. A significantly higher bone area fraction was observed for SL compared with SU (pimplant contact occurred was the highest for SL and significantly different from SU (pimplant contact was observed, a loading (SL versus SU: p=0.0049) as well as an implant geometry effect (SL versus CL: p=0.01) was found, in favour of the SL condition. Well-controlled immediate implant loading accelerates tissue mineralization at the interface. Adequate bone stimulation via mechanical coupling may account for the larger bone response around the screw-type implant compared with the cylindrical implant.

  20. Placement of central venous port catheters and peripherally inserted central catheters in the routine clinical setting of a radiology department: analysis of costs and intervention duration learning curve.

    Science.gov (United States)

    Rotzinger, Roman; Gebauer, Bernhard; Schnapauff, Dirk; Streitparth, Florian; Wieners, Gero; Grieser, Christian; Freyhardt, Patrick; Hamm, Bernd; Maurer, Martin H

    2017-12-01

    Background Placement of central venous port catheters (CVPS) and peripherally inserted central catheters (PICC) is an integral component of state-of-the-art patient care. In the era of increasing cost awareness, it is desirable to have more information to comprehensively assess both procedures. Purpose To perform a retrospective analysis of interventional radiologic implantation of CVPS and PICC lines in a large patient population including a cost analysis of both methods as well as an investigation the learning curve in terms of the interventions' durations. Material and Methods All CVPS and PICC line related interventions performed in an interventional radiology department during a three-year period from January 2011 to December 2013 were examined. Documented patient data included sex, venous access site, and indication for CVPS or PICC placement. A cost analysis including intervention times was performed based on the prorated costs of equipment use, staff costs, and expenditures for disposables. The decrease in intervention duration in the course of time conformed to the learning curve. Results In total, 2987 interventions were performed by 16 radiologists: 1777 CVPS and 791 PICC lines. An average implantation took 22.5 ± 0.6 min (CVPS) and 10.1 ± 0.9 min (PICC lines). For CVPS, this average time was achieved by seven radiologists newly learning the procedures after performing 20 CVPS implantations. Total costs per implantation were €242 (CVPS) and €201 (PICC lines). Conclusion Interventional radiologic implantations of CVPS and PICC lines are well-established procedures, easy to learn by residents, and can be implanted at low costs.

  1. Predictors of clinical outcome in total hip and knee replacement : a methodological appraisal of implants and patient factors

    NARCIS (Netherlands)

    Keurentjes, Johan Christiaan

    2014-01-01

    In this thesis, we studied both implants and patient and surgeon factors as predictors of clinical outcome after total hip and knee replacement. Additionally, we studied a number of methodological aspects of orthopaedic research, such as competing risks in estimating the probability of revision

  2. Modified cementless total coxofemoral prosthesis: development, implantation and clinical evaluation

    Directory of Open Access Journals (Sweden)

    S.A. Arias

    2013-12-01

    Full Text Available The aim of this study was to modify canine coxofemoral prostheses and the clinical evaluation of the implantation. Fifteen canine hips and femora of cadavers were used in order to study the surface points of modification in prostheses and develop a perforation guide. Femoral stems and acetabular components were perforated and coated with biphasic calcium phosphate layer. Twelve young adult male mongrel dogs were implanted with coxofemoral prostheses. Six were operated upon and implanted with cemented canine modular hip prostheses, establishing the control group. The remaining six were implanted with a novel design of cementless porous tricalcic phosphate-hydroxyapatite coated hip prostheses. Clinical and orthopedic performance, complications, and thigh muscular hypotrophy were assessed up to the 120th post-operatory day. After 120 days, animals with cementless prostheses had similar clinical and orthopedic performance compared to the cemented group despite the increased pain thigh hypotrophy. Animals that underwent cementless hip prosthesis evidenced more pain, compared to animals with cemented hip prosthesis that required longer recuperation time. No luxations, two fractures and two isquiatic neurapraxies were identified in the course of the study. Using both the cemented and the bioactive coated cementless model were suitable to dogs, showing clinical satisfactory results. Osseointegration and biological fixation were observed in the animals with the modified cementless hip prosthesis.

  3. Why are mini-implants lost: the value of the implantation technique!

    Science.gov (United States)

    Romano, Fabio Lourenço; Consolaro, Alberto

    2015-01-01

    The use of mini-implants have made a major contribution to orthodontic treatment. Demand has aroused scientific curiosity about implant placement procedures and techniques. However, the reasons for instability have not yet been made totally clear. The aim of this article is to establish a relationship between implant placement technique and mini-implant success rates by means of examining the following hypotheses: 1) Sites of poor alveolar bone and little space between roots lead to inadequate implant placement; 2) Different sites require mini-implants of different sizes! Implant size should respect alveolar bone diameter; 3) Properly determining mini-implant placement site provides ease for implant placement and contributes to stability; 4) The more precise the lancing procedures, the better the implant placement technique; 5) Self-drilling does not mean higher pressures; 6) Knowing where implant placement should end decreases the risk of complications and mini-implant loss.

  4. Why are mini-implants lost: The value of the implantation technique!

    Directory of Open Access Journals (Sweden)

    Fabio Lourenço Romano

    2015-02-01

    Full Text Available The use of mini-implants have made a major contribution to orthodontic treatment. Demand has aroused scientific curiosity about implant placement procedures and techniques. However, the reasons for instability have not yet been made totally clear. The aim of this article is to establish a relationship between implant placement technique and mini-implant success rates by means of examining the following hypotheses: 1 Sites of poor alveolar bone and little space between roots lead to inadequate implant placement; 2 Different sites require mini-implants of different sizes! Implant size should respect alveolar bone diameter; 3 Properly determining mini-implant placement site provides ease for implant placement and contributes to stability; 4 The more precise the lancing procedures, the better the implant placement technique; 5 Self-drilling does not mean higher pressures; 6 Knowing where implant placement should end decreases the risk of complications and mini-implant loss.

  5. Implant survival after total elbow arthroplasty

    DEFF Research Database (Denmark)

    Plaschke, Hans Christian; Thillemann, Theis M; Brorson, Stig

    2014-01-01

    in 234 patients at a mean follow-up of 8.7 years (range, 0-27 years). The overall 5-year survival was 90% (95% confidence interval [CI], 88%-94%), and 10-year survival was 81% (95% CI, 76%-86%). TEAs performed with the unlinked design had a relative risk of revision of 1.9 (95% CI, 1.1-3.2) compared...... was to evaluate implant survival and risk factors for revision of TEAs inserted in patients in the eastern part of Denmark in the period from 1980 until 2008. MATERIAL AND METHODS: The Danish National Patient Register provided personal identification numbers for patients who underwent TEA procedures from 1980...

  6. [Subcutaneous implantation type central venous port management in patients with malignant tumors effect of different antiseptic agents on central venous port-related infection].

    Science.gov (United States)

    Sato, Junya; Kumagai, Masumi; Kato, Kenichi; Akahane, Akio; Suzuki, Michiko; Kashiwaba, Masahiro; Sone, Miyuki; Kudo, Kenzo

    2014-08-01

    Subcutaneous implantation type central venous ports(CV ports)are used in chemotherapy. Here, we prospectively examined the frequency of CV port-related infections when the disinfectant was changed from 10% povidone iodine to 1% chlorhexidine ethanol or 70% ethanol. The subjects were patients with malignant tumors, who had newly been implanted with CV ports. We examined CV port-related infections at 1 week after CV port implantation and every 2 weeks thereafter, following sterilization upon insertion of a Huber needle to the CV port. CV port evulsion due to CV port-related infection was noted in 3 patients(4.8%)in whom 15%chlorhexidine ethanol was used(n=62)and in 2 patients(3.3%)in whom 70% ethanol was used(n=60). Infection rates per 1,000 days of CV port use were 1.48% and 1.01%, respectively. Thus, the outcomes of sterilization using 1% chlorhexidine ethanol and 70% ethanol did not differ significantly from those on using 10% povidone iodine for sterilization, based on preliminary results at our institution(3 of 59 patients[5.1%]had port evulsion due to CV port-related infection and the infection rate per 1,000 days of CV port use was 1.47%, Akahane et al, 2012). Chlorhexidine ethanol and ethanol are very convenient to use because they dry quickly and do not need discoloration. Accordingly, chlorhexidine ethanol and ethanol might be useful in CV port management.

  7. Effect of implant number and distribution on load transfer in implant-supported partial fixed dental prostheses for the anterior maxilla: A photoelastic stress analysis study.

    Science.gov (United States)

    Lee, Jae-In; Lee, Yoon; Kim, Yu-Lee; Cho, Hye-Won

    2016-02-01

    The 4-, 3- or even 2-implant-supported partial fixed dental prosthesis (PFDP) designs have been used to rehabilitate the anterior edentulous maxilla. The purpose of this in vitro study was to compare the stress distribution in the supporting tissues surrounding implants placed in the anterior maxilla with 5 PFDP designs. A photoelastic model of the human maxilla with an anterior edentulous region was made with photoelastic resin (PL-2; Vishay Micro-Measurements), and 6 straight implants (OsseoSpeed; Astra Tech AB) were placed in the 6 anterior tooth positions. The 5 design concepts based on implant location were as follows: model 6I: 6 implants; model 2C2CI: 4 implants (2 canines and 2 central incisors); model 2C2LI: 4 implants (2 canines and 2 lateral incisors); model 2C1CI: 3 implants (2 canines and 1 central incisor); and model 2C: 2 canines. A load of 127.4 N was applied on the cingulum of 3 teeth at a 30-degree angle to the long axis of the implant. Stresses that developed in the supporting structure were recorded photographically. The 6-implant-supported PFDP exhibited the most even and lowest distribution of stresses in all loading conditions. When the canine was loaded, the 2- or 3-implant-supported PFDP showed higher stresses around the implant at the canine position than did the 4- or 6-implant-supported PFDP. When the central incisor or lateral incisor was loaded, the two 4-implant-supported PFDPs exhibited similar levels of stresses around the implants and showed lower stresses than did the 2- or 3-implant-supported PFDP. Implant number and distribution influenced stress distribution around the implants in the anterior maxilla. With a decrease in implant number, the stresses around the implants increased. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  8. Placement of a Port Catheter Through Collateral Veins in a Patient with Central Venous Occlusion

    International Nuclear Information System (INIS)

    Teichgraeber, Ulf Karl-Martin; Streitparth, Florian; Gebauer, Bernhard; Benter, Thomas

    2010-01-01

    Long-term utilization of central venous catheters (CVCs) for parenteral nutrition has a high incidence of central venous complications including infections, occlusions, and stenosis. We report the case of a 31-year-old woman presenting with a malabsorption caused by short gut syndrome due to congenital aganglionic megacolon. The patient developed a chronic occlusion of all central neck and femoral veins due to long-term use of multiple CVCs over more than 20 years. In patients with central venous occlusion and venous transformation, the implantation of a totally implanted port system by accessing collateral veins is an option to continue long-term parenteral nutrition when required. A 0.014-in. Whisper guidewire (Terumo, Tokyo) with high flexibility and steerability was chosen to maneuver and pass through the collateral veins. We suggest this approach to avoid unfavorable translumbar or transhepatic central venous access and to conserve the anatomically limited number of percutaneous access sites.

  9. Machine learning techniques for the optimization of joint replacements: Application to a short-stem hip implant.

    Science.gov (United States)

    Cilla, Myriam; Borgiani, Edoardo; Martínez, Javier; Duda, Georg N; Checa, Sara

    2017-01-01

    Today, different implant designs exist in the market; however, there is not a clear understanding of which are the best implant design parameters to achieve mechanical optimal conditions. Therefore, the aim of this project was to investigate if the geometry of a commercial short stem hip prosthesis can be further optimized to reduce stress shielding effects and achieve better short-stemmed implant performance. To reach this aim, the potential of machine learning techniques combined with parametric Finite Element analysis was used. The selected implant geometrical parameters were: total stem length (L), thickness in the lateral (R1) and medial (R2) and the distance between the implant neck and the central stem surface (D). The results show that the total stem length was not the only parameter playing a role in stress shielding. An optimized implant should aim for a decreased stem length and a reduced length of the surface in contact with the bone. The two radiuses that characterize the stem width at the distal cross-section in contact with the bone were less influential in the reduction of stress shielding compared with the other two parameters; but they also play a role where thinner stems present better results.

  10. Implantation technique of the 50-cm3 SynCardia Total Artificial Heart: does size make a difference?

    Science.gov (United States)

    Spiliopoulos, Sotirios; Guersoy, Dilek; Dimitriou, Alexandros Merkourios; Koerfer, Reiner; Tenderich, Gero

    2015-01-01

    Despite downsizing, implantation technique of the 50-cm(3) SynCardia Total Artificial Heart and settings of the Companion driver remain unchanged. Owing to the absence of de-airing nipples, de-airing procedure is even more crucial and has to be performed carefully. © The Author 2015. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  11. Dexamethasone Implant (Ozurdex in a Case with Unilateral Simultaneous Central Retinal Vein and Branch Retinal Artery Occlusion

    Directory of Open Access Journals (Sweden)

    Taylan Ozturk

    2015-02-01

    Full Text Available Simultaneous branch retinal artery and vein occlusion is a rare condition that may cause severe visual loss, and its treatment is often unrewarding. Herein, we report a case with simultaneous central retinal vein and branch retinal artery occlusion; it was successfully treated with a single dexamethasone intravitreal implant. The affected eye attained a visual acuity level of 20/25 from the visual acuity of hand motions at presentation with a residual, but relatively diminished, altitudinal scotoma during a follow-up period of 6 months.

  12. Veno-venous extracorporeal membrane oxygenation using an innovative dual-lumen cannula following implantation of a total artificial heart.

    Science.gov (United States)

    Youdle, Jemma; Penn, Sarah; Maunz, Olaf; Simon, Andre

    2017-01-01

    We report our first clinical use of the new Protek Duo TM cannula for peripheral veno-venous extra-corporeal life support (ECLS). A 53-year-old male patient underwent implantation of a total artificial heart (TAH) for biventricular failure. However, due to the development of post-operative respiratory dysfunction, the patient required ECLS for six days.

  13. Comparison of Venae Sectio vs. modified Seldinger Technique for Totally Implantable Access Ports; Portas-trial [ISRCTN:52368201

    Directory of Open Access Journals (Sweden)

    Luntz S

    2006-06-01

    Full Text Available Abstract Background The insertion of a Totally Implantable Access Port (TIAP is a routinely employed technique in patients who need a safe and permanent venous access. The number of TIAP implantations is increasing constantly mainly due to advanced treatment options for malignant diseases. Therefore it is important to identify the implantation technique which has the optimal benefit/risk ratio for the patient. Study design A single-centre, randomized, controlled superiority trial to compare two different TIAP implantation techniques. Sample size: 160 patients will be included and randomized intra-operatively. Eligibility criteria: Age equal or older than 18 years, patients scheduled for primary elective implantation of a TIAP in local anaesthesia and a signed informed consent. Primary endpoint: Primary success rate of the randomized technique. Intervention: Venae Sectio in combination with the Seldinger Technique (guide wire and a peel away sheath will be used to place a TIAP. Reference treatment: Conventional Venae Sectio will be used with a direct insertion of the TIAP without guide wire or peel away sheath. Duration of study: Approximately 20 months. Organisation/Responsibility The trial will be conducted in compliance with the protocol and in accordance with the moral, ethical, and scientific principles governing clinical research as set out in the Declaration of Helsinki (1989 and Good Clinical Practice (GCP. The trial will also be carried out in keeping with local and regulatory requirements. The Klinisches Studienzentrum Chirurgie (KSC – Centre of Clinical Trials in Surgery at the Department of Surgery, University Hospital Heidelberg is responsible for planning and conduction of the trial. Documentation of patient's data will be accomplished via electronical Case Report Files (eCRF with MACRO®-Software by the KSC. Randomization, data management, monitoring and biometry are provided by the independent Koordinierungszentrum f

  14. Survival of Implants in Immediate Extraction Sockets of Anterior Teeth: Early Clinical Results.

    Science.gov (United States)

    Sabir, Mohammad; Alam, Mohammad Nazish

    2015-06-01

    The aims and objectives of this study were placement of implants in freshly extracted sockets of anterior teeth and to evaluate the implant stability, peri-implant radiolucency and gingival inflammation around implant over a short period of 30 months. A total of 12 patients (8 male and 4 female), ranging in the age from 20 to 50 years, from March 2007 to June 2007, were evaluated for immediate implant placement into 22 fresh extraction sockets. Only maxillary and mandibular anterior teeth/roots (central incisors, lateral incisors and canines) were considered for replacement with implants. One piece implant with integrated abutment and integrated surface, non-submerged, threaded and tapered at apical 5 mm, sand-blasted and acid etched surfaced implants (HI-TEC TRX-OP Implants of Life Care Company) were used. The mobility was not present in any of the implants at all the follow up visits. There were 2 implants at 6 month, 1 implant at 12 month, 1 implant at 18 month visits, showing peri-implant radiolucency at some sites at bone to implant contact site. Severe gingival inflammation was not observed in any of the implant site. At every follow-up visit, every implant met the criteria of success and none was found to be failed over a 30 months duration i.e. 100% success rate was achieved by implants in immediate extraction socket. The success rate of implant survival in this study was found 100%. These implants have fulfilled all the criteria of implant success and based on the defined criteria, the success rate of implants placed in immediate extraction sockets of anterior teeth compared favorably with the conventional implants. The early results of the present study showed that high survival rates with the implants in immediate extraction sockets can be achieved.

  15. Protocol of an expertise based randomized trial comparing surgical Venae Sectio versus radiological Puncture of Vena Subclavia for insertion of Totally Implantable Access Port in oncological patients

    Directory of Open Access Journals (Sweden)

    Radeleff Boris

    2008-10-01

    Full Text Available Abstract Background Totally Implantable Access Ports (TIAP are being extensively used world-wide and can be expected to gain further importance with the introduction of new neoadjuvant and adjuvant treatments in oncology. Two different techniques for the implantation can be selected: A direct puncture of a central vein and the utilization of a Seldinger device or the surgical Venae sectio. It is still unclear which technique has the optimal benefit/risk ratio for the patient. Design A single-center, expertise based randomized, controlled superiority trial to compare two different TIAP implantation techniques. 100 patients will be included and randomized pre-operatively. All patients aged 18 years or older scheduled for primary elective implantation of a TIAP under local anesthesia who signed the informed consent will be included. The primary endpoint is the primary success rate of the randomized technique. Control Intervention: Venae Sectio will be employed to insert a TIAP by a surgeon; Experimental intervention: Punction of V. Subclavia will be used to place a TIAP by a radiologist. Duration of study: Approximately 10 months, follow up time: 90 days. Organisation/Responsibility The PORTAS 2 – Trial will be conducted in accordance with the protocol and in compliance with the moral, ethical, and scientific principles governing clinical research as set out in the Declaration of Helsinki (1989 and Good Clinical Practice (GCP. The Center of Clinical Trials at the Department of Surgery, University Hospital Heidelberg is responsible for design and conduct of the trial including randomization and documentation of patients' data. Data management and statistical analysis will be performed by the independent Institute for Medical Biometry and Informatics (IMBI, University of Heidelberg. Trial Registration The trial is registered at ClinicalTrials.gov (NCT00600444.

  16. Bimaxillary protrusion with an atrophic alveolar defect: orthodontics, autogenous chin-block graft, soft tissue augmentation, and an implant.

    Science.gov (United States)

    Chiu, Grace S C; Chang, Chris H N; Roberts, W Eugene

    2015-01-01

    Bimaxillary protrusion in a 28-year-old woman was complicated by multiple missing, restoratively compromised, or hopeless teeth. The maxillary right central incisor had a history of avulsion and replantation that subsequently evolved into generalized external root resorption with Class III mobility and severe loss of the supporting periodontium. This complex malocclusion had a discrepancy index of 21, and 8 additional points were scored for the atrophic dental implant site (maxillary right central incisor). The comprehensive treatment plan included extraction of 4 teeth (both maxillary first premolars, the maxillary right central incisor, and the mandibular right first molar), orthodontic closure of all spaces except for the future implant site (maxillary right central incisor), augmentation of the alveolar defect with an autogenous chin-block graft, enhancement of the gingival biotype with a connective tissue graft, and an implant-supported prosthesis. Orthodontists must understand the limitations of bone grafts. Augmented alveolar defects are slow to completely turn over to living bone, so they are usually good sites for implants but respond poorly to orthodontic space closure. However, postsurgical orthodontic treatment is often indicated to optimally finish the esthetic zone before placing the final prosthesis. The latter was effectively performed for this patient, resulting in a total treatment time of about 36 months for comprehensive interdisciplinary care. An excellent functional and esthetic result was achieved. Copyright © 2015 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.

  17. Experimental research of covered stent implanted in canine hepatic artery

    International Nuclear Information System (INIS)

    Zhou Bing; Liu Linxiang; Li Minghua; Wang Yongli; Cheng Yongde

    2007-01-01

    Objective: To evaluate the feasibility of success rate of implantation, post-procedure stenosis rate, apposition ability and endothelialization level, etc. for implantation with balloon-expandable covered stent in canine hepatic artery. Methods: 8 adult canines were implanted with balloon-expendable stents covered by expandable poly Teflon ester membrane (e-PTFEM). Follow-up DSA was performed immediately, 2, 4 and 12 wk after the procedure. The canines were sacrificed for histopathologic examination and statistical analysis with correlation of implantation manenvor and angiographic manifestations. Results: 8 cases were all implanted with the covered stents in proper hepatic artery/right hepatic artery successfully; showing good apposition ability and non-opacification of the separated branches. 2 cases showed intraluminal obvious stenosis( > 50%)of the stent at 2 weeks follow-up, so did 3 cases at 12 weeks follow-up, and the total stenosis rate was 37.5% and 5 cases manifested full endothelialization (3 different locations of the sample all manifested full endothelialization), 3 cased manifested partial endothelialization (at least 1 location of the sample didn't show full endothelialization), and the two terminal parts were easier to get endothelialization than the central part. Before and after the stent implantation, hepatic function of all cases didn't demonstrate any obvious changes. Conclusions: Balloon-expandable covered stent can be implanted in canine hepatic artery. successfully, with good apposition ability, full endothelialization, and no influence on hepatic function. (authors)

  18. Quantification of in vivo implant wear in total knee replacement from dynamic single plane radiography

    Science.gov (United States)

    Teeter, Matthew G.; Seslija, Petar; Milner, Jaques S.; Nikolov, Hristo N.; Yuan, Xunhua; Naudie, Douglas D. R.; Holdsworth, David W.

    2013-05-01

    An in vivo method to measure wear in total knee replacements was developed using dynamic single-plane fluoroscopy. A dynamic, anthropomorphic total knee replacement phantom with interchangeable, custom-fabricated components of known wear volume was created, and dynamic imaging was performed. For each frame of the fluoroscopy data, the relative location of the femoral and tibial components were determined, and the apparent intersection of the femoral component with the tibial insert was used to calculate wear volume, wear depth, and frequency of intersection. No difference was found between the measured and true wear volumes. The precision of the measurements was ±39.7 mm3 for volume and ±0.126 mm for wear depth. The results suggest the system is capable of tracking wear volume changes across multiple time points in patients. As a dynamic technique, this method can provide both kinematic and wear measurements that may be useful for evaluating new implant designs for total knee replacements.

  19. Quantification of in vivo implant wear in total knee replacement from dynamic single plane radiography

    International Nuclear Information System (INIS)

    Teeter, Matthew G; Naudie, Douglas D R; Holdsworth, David W; Seslija, Petar; Milner, Jaques S; Nikolov, Hristo N; Yuan Xunhua

    2013-01-01

    An in vivo method to measure wear in total knee replacements was developed using dynamic single-plane fluoroscopy. A dynamic, anthropomorphic total knee replacement phantom with interchangeable, custom-fabricated components of known wear volume was created, and dynamic imaging was performed. For each frame of the fluoroscopy data, the relative location of the femoral and tibial components were determined, and the apparent intersection of the femoral component with the tibial insert was used to calculate wear volume, wear depth, and frequency of intersection. No difference was found between the measured and true wear volumes. The precision of the measurements was ±39.7 mm 3 for volume and ±0.126 mm for wear depth. The results suggest the system is capable of tracking wear volume changes across multiple time points in patients. As a dynamic technique, this method can provide both kinematic and wear measurements that may be useful for evaluating new implant designs for total knee replacements. (paper)

  20. Preoperative Biometric Parameters Predict the Vault after ICL Implantation: A Retrospective Clinical Study.

    Science.gov (United States)

    Zheng, Qian-Yin; Xu, Wen; Liang, Guan-Lu; Wu, Jing; Shi, Jun-Ting

    2016-01-01

    To investigate the correlation between the preoperative biometric parameters of the anterior segment and the vault after implantable Collamer lens (ICL) implantation via this retrospective study. Retrospective clinical study. A total of 78 eyes from 41 patients who underwent ICL implantation surgery were included in this study. Preoperative biometric parameters, including white-to-white (WTW) diameter, central corneal thickness, keratometer, pupil diameter, anterior chamber depth, sulcus-to-sulcus diameter, anterior chamber area (ACA) and central curvature radius of the anterior surface of the lens (Lenscur), were measured. Lenscur and ACA were measured with Rhinoceros 5.0 software on the image scanned with ultrasound biomicroscopy (UBM). The vault was assessed by UBM 3 months after surgery. Multiple stepwise regression analysis was employed to identify the variables that were correlated with the vault. The results showed that the vault was correlated with 3 variables: ACA (22.4 ± 4.25 mm2), WTW (11.36 ± 0.29 mm) and Lenscur (9.15 ± 1.21 mm). The regressive equation was: vault (mm) = 1.785 + 0.017 × ACA + 0.051 × Lenscur - 0.203 × WTW. Biometric parameters of the anterior segment (ACA, WTW and Lenscur) can predict the vault after ICL implantation using a new regression equation. © 2016 The Author(s) Published by S. Karger AG, Basel.

  1. Durability of central aortic valve closure in patients with continuous flow left ventricular assist devices.

    Science.gov (United States)

    McKellar, Stephen H; Deo, Salil; Daly, Richard C; Durham, Lucian A; Joyce, Lyle D; Stulak, John M; Park, Soon J

    2014-01-01

    A competent aortic valve is essential to providing effective left ventricular assist device support. We have adopted a practice of central aortic valve closure by placing a simple coaptation stitch at left ventricular assist device implantation in patients with significant aortic insufficiency. We conducted a follow-up study to evaluate the efficacy and durability of this procedure. The study included patients who had undergone continuous flow left ventricular assist device implantation. The patients were divided into 2 groups, those who did not require any aortic procedure because the valve was competent and those who underwent central aortic valve closure for mild or greater aortic regurgitation. The clinical endpoints were mortality, progression or recurrence of aortic insufficiency, and reoperation for aortic valve pathologic features. Aortic insufficiency was measured qualitatively from mild to severe on a scale of 0 to 5. A total of 123 patients received continuous flow left ventricular assist devices from February 2007 to August 2011. Of those, 18 (15%) underwent central aortic valve closure at left ventricular assist device implantation because of significant aortic insufficiency (1.8 ± 1.4) and 105 who did not (competent aortic valve, 0.15 ± 0.43; P assist device-supported patients, with follow-up extending into 2 years. Although aortic insufficiency progressed over time in those with minimal native valve regurgitation initially, no such progression was noted in those with central aortic valve closure. Additional investigation is needed to evaluate whether prophylactic central aortic valve closure should be performed at left ventricular assist device implantation to avoid problematic aortic regurgitation developing over time, in particular in patients undergoing left ventricular assist device implantation for life-long (destination therapy) support. Copyright © 2014 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights

  2. Correction of Malpositioned Implants through Periodontal Surgery and Prosthetic Rehabilitation Using Angled Abutment

    Directory of Open Access Journals (Sweden)

    Érica Dorigatti de Avila

    2014-01-01

    Full Text Available When dental implants are malpositioned in relation to the adjacent teeth and alveolar bone or in an excessive buccal or lingual position, the final prosthesis rehabilitation impairs the peri-implant health of the gingival tissues and the aesthetics of the patient. Thus, the purpose of this case was to report and discuss a multidisciplinary protocol for the treatment of a compromised maxillary tooth in a patient with an abscess in his right central incisor due to an excessive buccal implant position. The patient presented with an implant-supported provisional restoration on his right maxillary central incisor and a traumatic injury in his left central incisor. The treatment protocol consisted in (i abutment substitution to compensate the incorrect angulation of the implant, (ii clinical crown lengthening, (iii atraumatic extraction of the left central incisor, and (iv immediate implant placement. Finally, (v a custom abutment was fabricated to obtain a harmonious gingival contour around the prosthetic crown. In conclusion, when implants are incorrectly positioned in relation to the adjacent teeth, associated with soft-tissue defects, the challenge to create a harmonious mucogingival contours may be achieved with an interdisciplinary approach and with the placement of an appropriate custom abutment.

  3. Tribo-biological deposits on the articulating surfaces of metal-on-polyethylene total hip implants retrieved from patients

    Science.gov (United States)

    Cui, Zhiwei; Tian, Yi-Xing; Yue, Wen; Yang, Lei; Li, Qunyang

    2016-06-01

    Artificial total hip arthroplasty (THA) is one of the most effective orthopaedic surgeries that has been used for decades. However, wear of the articulating surfaces is one of the key failure causes limiting the lifetime of total hip implant. In this paper, Fourier transform infrared spectroscopy (FTIR), X-ray photoelectron spectroscopy (XPS) and atomic force microscopy (AFM) were employed to explore the composition and formation mechanism of the tribo-layer on the articulating surfaces of metal-on-polyethylene (MoPE) implants retrieved from patients. Results showed that, in contrast to conventional understanding, the attached tribo-layer contained not only denatured proteins but also a fraction of polymer particles. The formation of the tribo-layer was believed to relate to lubrication regime, which was supposed to be largely affected by the nature of the ultra-high-molecule-weight-polyethylene (UHMWPE). Wear and formation of tribo-layer could be minimized in elasto-hydrodynamic lubrication (EHL) regime when the UHMWPE was less stiff and have a morphology containing micro-pits; whereas the wear was more severe and tribo-layer formed in boundary lubrication. Our results and analyses suggest that enhancing interface lubrication may be more effective on reducing wear than increasing the hardness of material. This finding may shed light on the design strategy of artificial hip joints.

  4. Peri-implant bone strains and micro-motion following in vivo service: a postmortem retrieval study of 22 tibial components from total knee replacements.

    Science.gov (United States)

    Mann, Kenneth A; Miller, Mark A; Goodheart, Jacklyn R; Izant, Timothy H; Cleary, Richard J

    2014-03-01

    Biological adaptation following placement of a total knee replacements (TKRs) affects peri-implant bone mineral density (BMD) and implant fixation. We quantified the proximal tibial bone strain and implant-bone micro-motion for functioning postmortem retrieved TKRs and assessed the strain/micro-motion relationships with chronological (donor age and time in service) and patient (body weight and BMD) factors. Twenty-two tibial constructs were functionally loaded to one body weight (60% medial/40% lateral), and the bone strains and tray/bone micro-motions were measured using a digital image correlation system. Donors with more time in service had higher bone strains (p = 0.044), but there was not a significant (p = 0.333) contribution from donor age. Donors with lower peri-implant BMD (p = 0.0039) and higher body weight (p = 0.0286) had higher bone strains. Long term implants (>11 years) had proximal bone strains 900 µϵ that were almost twice as high as short term (implants 570 µϵ. Micro-motion was greater for younger donors (p = 0.0161) and longer time in service (p = 0.0008). Increased bone strain with long term in vivo service could contribute to loosening of TKRs by failure of the tibial peri-implant bone. © 2013 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  5. Group D. Initiator paper. Implants--peri-implant (hard and soft tissue) interactions in health and disease: the impact of explosion of implant manufacturers.

    Science.gov (United States)

    Ivanovski, Saso

    2015-01-01

    1. The best-documented implants have a threaded solid screw-type design and are manufactured from commercially pure (grade IV) titanium. There is good evidence to support implants ≥ 6 mm in length, and ≥ 3 mm in diameter. 2. Integrity of the seal between the abutment and the implant is important for several reasons, including minimization of mechanical and biological complications and maintaining marginal bone levels. Although the ideal design features of the implant-abutment connection have not been determined, an internal connection, micro-grooves at the implant collar, and horizontal offset of the implant-abutment junction (platform switch) appear to impart favorable properties. 3. Implants with moderately rough implant surfaces provide advantages over machined surfaces in terms of the speed and extent of osseointegration. While the favorable performances of both minimally and moderately rough surfaces are supported by long-term data, moderately rough surfaces provide superior outcomes in compromised sites, such as the posterior maxilla. 4. Although plaque is critical in the progression of peri-implantitis, the disease has a multi-factorial aetiology, and may be influenced by poor integrity of the abutment/implant connection. Iatrogenic factors, such as the introduction of a foreign body. (e.g., cement) below the mucosal margin, can be important contributors. 5. Clinicians should exercise caution when using a particular implant system, ensuring that the implant design is appropriate and supported by scientific evidence. Central to this is access to and participation in quality education on the impact that implant characteristics can have on clinical outcomes. Caution should be exercised in utilizing non-genuine restorative componentry that may lead to a poor implant-abutment fit and subsequent technical and biological complications.

  6. Preservation of keratinized mucosa around implants using a prefabricated implant-retained stent: a case-control study

    OpenAIRE

    Kim, Chang-Soon; Duong, Hieu Pham; Park, Jung-Chul; Shin, Hyun-Seung

    2016-01-01

    Purpose The aim of this study was to clinically assess the impact of a prefabricated implant-retained stent clipped over healing abutments on the preservation of keratinized mucosa around implants after implant surgery, and to compare it with horizontal external mattress sutures. Methods A total of 50 patients were enrolled in this study. In the test group, a prefabricated implant-retained stent was clipped on the healing abutment after implant surgery to replace the keratinized tissue bucco-...

  7. Implant Supported Fixed Restorations versus Implant Supported Removable Overdentures: A Systematic Review

    Science.gov (United States)

    Selim, Khaled; Ali, Sherif; Reda, Ahmed

    2016-01-01

    AIM: The aim of this study is to systematically evaluate and compare implant retained fixed restoration versus implant retained over denture. MATERIAL AND METHODS: Search was made in 2 databases including PubMed and PubMed Central. Title and abstract were screened to select studies comparing implant retained fixed restorations versus implant retained removable overdentures. Articles which did not follow the inclusion criteria were excluded. Included papers were then read carefully for a second stage filter, this was followed by manual searching of bibliography of selected articles. RESULTS: The search resulted in 5 included papers. One study evaluated the masticatory function, while the other 4 evaluated the patient satisfaction. Two of them used Visual Analogue Scale (VAS) as a measurement tool, while the other two used VAS and Categorical Scales (CAT). Stability, ability to chew, ability to clean, ability to speak and esthetics were the main outcomes of the 4 included papers. CONCLUSION: Conflicting results was observed between the fixed and removable restorations. PMID:28028423

  8. An analysis of reliability and validity of the papilla index score of implant-supported single crowns of maxillary central incisors

    DEFF Research Database (Denmark)

    Peng, Min; Fei, Wei; Hosseini, Mandana

    2012-01-01

    Objectives: To test the reliability and validity of the papilla index scores of the implant-supported single crowns (ISSCs) of maxillary central incisors. Materials and Methods: Twenty-five patients with 25 ISSCs were included. Two prosthodontists evaluated the papilla index score (PIS) of three...... inter-observer agreement. The PIS score demonstrated significant correlation to the corresponding PP value (rs=.567, p=.000). Conclusions: The feasibility, reliability and validity of the PIS made the parameter useful for quality control of the pri-implant soft tissue of ISSCs....... fill percent (PP) was calculated. The validity of PIS was tested against the corresponding papilla fill percent (PP) by using the Spearman correlation analysis. Results: The intra-observer agreement was >70% in 4/5 and >50% in all observations, the pooled Cohen’s ¿ was 0.64 and 0.70 for two observers...

  9. A comparative study on the stress distribution around dental implants in three arch form models for replacing six implants using finite element analysis.

    Science.gov (United States)

    Zarei, Maryam; Jahangirnezhad, Mahmoud; Yousefimanesh, Hojatollah; Robati, Maryam; Robati, Hossein

    2018-01-01

    Dental implant is a method to replacement of missing teeth. It is important for replacing the missed anterior teeth. In vitro method is a safe method for evaluation of stress distribution. Finite element analysis as an in vitro method evaluated stress distribution around replacement of six maxillary anterior teeth implants in three models of maxillary arch. In this in vitro study, using ABAQUS software (Simulia Corporation, Vélizy-Villacoublay, France), implant simulation was performed for reconstruction of six maxillary anterior teeth in three models. Two implants were placed on both sides of the canine tooth region (A model); two implants on both sides of the canine tooth region and another on one side of the central incisor region (B model); and two implants on both sides of the canine tooth region and two implants in the central incisor area (C model). All implants evaluated in three arch forms (tapered, ovoid, and square). Data were analyzed by finite analysis software. Von Mises stress by increasing of implant number was reduced. In a comparison of A model in each maxillary arch, the stress created in the cortical and cancellous bones in the square arch was less than ovoid and tapered arches. The stress created in implants and cortical and cancellous bones in C model was less than A and B models. The C model (four-implant) reduced the stress distribution in cortical and cancellous bones, but this pattern must be evaluated according to arch form and cost benefit of patients.

  10. Trends in cochlear implants.

    Science.gov (United States)

    Zeng, Fan-Gang

    2004-01-01

    More than 60,000 people worldwide use cochlear implants as a means to restore functional hearing. Although individual performance variability is still high, an average implant user can talk on the phone in a quiet environment. Cochlear-implant research has also matured as a field, as evidenced by the exponential growth in both the patient population and scientific publication. The present report examines current issues related to audiologic, clinical, engineering, anatomic, and physiologic aspects of cochlear implants, focusing on their psychophysical, speech, music, and cognitive performance. This report also forecasts clinical and research trends related to presurgical evaluation, fitting protocols, signal processing, and postsurgical rehabilitation in cochlear implants. Finally, a future landscape in amplification is presented that requires a unique, yet complementary, contribution from hearing aids, middle ear implants, and cochlear implants to achieve a total solution to the entire spectrum of hearing loss treatment and management.

  11. The effect of a single infusion of zoledronic acid on early implant migration in total hip arthroplasty. A randomized, double-blind, controlled trial.

    Science.gov (United States)

    Friedl, Gerald; Radl, Roman; Stihsen, Christoph; Rehak, Peter; Aigner, Reingard; Windhager, Reinhard

    2009-02-01

    Aseptic loosening is the most frequent cause of implant failure in total hip arthroplasty. While a direct link between aseptic loosening and periprosthetic bone loss remains elusive, there is plentiful evidence for a close association with early implant migration. The present trial was primarily designed to evaluate whether a single infusion of 4 mg of zoledronic acid prevented early implant migration in patients with osteonecrosis of the femoral head. Fifty patients were consecutively enrolled to receive either zoledronic acid or saline solution after cementless total hip arthroplasty. Radiographs, biochemical parameters of bone turnover, and the Harris hip-rating score were determined preoperatively and at each follow-up examination at seven weeks, six months, one year, and yearly thereafter. The median follow-up period was 2.8 years. We found a significant subsidence of the stem of up to a mean (and standard deviation) of -1.2 +/- 0.6 mm at two years within the control group, and the cups had a mean medialization of 0.6 +/- 1.0 mm and a mean cranialization of 0.6 +/- 0.8 mm (p < 0.001). Treatment with zoledronic acid effectively minimized the migration of the cups in both the transverse and the vertical direction (mean, 0.15 +/- 0.6 mm and 0.06 +/- 0.6 mm, respectively; p < 0.05), while only a trend to decreased subsidence of the stem was detected. Finally, the Harris hip score rapidly increased over time in both treatment groups, although this increase was significantly more pronounced in the zoledronate-treated group than in the control group (analysis of variance, p = 0.008). A single infusion of zoledronic acid shows promise in improving initial fixation of a cementless implant, which may improve the clinical outcome of total hip arthroplasty in patients with osteonecrosis of the femoral head.

  12. Chronic multisite brain recordings from a totally implantable bidirectional neural interface: experience in 5 patients with Parkinson's disease.

    Science.gov (United States)

    Swann, Nicole C; de Hemptinne, Coralie; Miocinovic, Svjetlana; Qasim, Salman; Ostrem, Jill L; Galifianakis, Nicholas B; Luciano, Marta San; Wang, Sarah S; Ziman, Nathan; Taylor, Robin; Starr, Philip A

    2018-02-01

    OBJECTIVE Dysfunction of distributed neural networks underlies many brain disorders. The development of neuromodulation therapies depends on a better understanding of these networks. Invasive human brain recordings have a favorable temporal and spatial resolution for the analysis of network phenomena but have generally been limited to acute intraoperative recording or short-term recording through temporarily externalized leads. Here, the authors describe their initial experience with an investigational, first-generation, totally implantable, bidirectional neural interface that allows both continuous therapeutic stimulation and recording of field potentials at multiple sites in a neural network. METHODS Under a physician-sponsored US Food and Drug Administration investigational device exemption, 5 patients with Parkinson's disease were implanted with the Activa PC+S system (Medtronic Inc.). The device was attached to a quadripolar lead placed in the subdural space over motor cortex, for electrocorticography potential recordings, and to a quadripolar lead in the subthalamic nucleus (STN), for both therapeutic stimulation and recording of local field potentials. Recordings from the brain of each patient were performed at multiple time points over a 1-year period. RESULTS There were no serious surgical complications or interruptions in deep brain stimulation therapy. Signals in both the cortex and the STN were relatively stable over time, despite a gradual increase in electrode impedance. Canonical movement-related changes in specific frequency bands in the motor cortex were identified in most but not all recordings. CONCLUSIONS The acquisition of chronic multisite field potentials in humans is feasible. The device performance characteristics described here may inform the design of the next generation of totally implantable neural interfaces. This research tool provides a platform for translating discoveries in brain network dynamics to improved neurostimulation

  13. Prevention and management of cochlear implant infections.

    Science.gov (United States)

    Gluth, Michael B; Singh, Rajesh; Atlas, Marcus D

    2011-11-01

    Understanding the issues of infection related to an implantable medical device is crucial to all cochlear implant teams. Furthermore, given the risk of central nervous system complications and the relatively high quantity of underlying resource investment associated with cochlear implantation, the stakes of infection are high. The optimal strategies to prevent and manage such infections are still evolving as good-quality prospective data to guide such management decisions are not yet abundant within the medical literature and many recommendations are based on retrospective reviews or anecdotal evidence. We will outline a general strategy to deal with cochlear implant-related infection based on both the authors' experience and the published literature.

  14. Current State and Future Perspectives of Energy Sources for Totally Implantable Cardiac Devices.

    Science.gov (United States)

    Bleszynski, Peter A; Luc, Jessica G Y; Schade, Peter; PhilLips, Steven J; Tchantchaleishvili, Vakhtang

    There is a large population of patients with end-stage congestive heart failure who cannot be treated by means of conventional cardiac surgery, cardiac transplantation, or chronic catecholamine infusions. Implantable cardiac devices, many designated as destination therapy, have revolutionized patient care and outcomes, although infection and complications related to external power sources or routine battery exchange remain a substantial risk. Complications from repeat battery replacement, power failure, and infections ultimately endanger the original objectives of implantable biomedical device therapy - eliminating the intended patient autonomy, affecting patient quality of life and survival. We sought to review the limitations of current cardiac biomedical device energy sources and discuss the current state and trends of future potential energy sources in pursuit of a lifelong fully implantable biomedical device.

  15. [Bentall operation combined with total arch replacement and stented elephant trunk implantation for serious Debakey I aortic dissecting aneurysm].

    Science.gov (United States)

    Gu, Tian-Xiang; Wang, Chun; Zhang, Yu-Hai

    2008-12-01

    To summarize the clinical experience of Bentall operation combined with total arch replacement and stented elephant trunk implantation for serious Debakey I aortic dissecting aneurysm. Twelve patients with serious Debakey I aortic dissecting aneurysm underwent surgical treatment from January 2005 to December 2007. There were 10 male and 2 female with the mean age of (40.1 +/- 9.5) years old. There were acute aortic dissection in 9 cases, chronic aortic dissection in 3 cases. The inner diameter of aorta was (5.3 +/- 1.8) cm. There were Marfan syndrome in 4 cases, aortic regurgitation in all cases, severely persistent chest pain in 9 cases, acute left heart failure in 8 cases, and cardiac tamponade in 4 cases. Bentall operations combined with total arch replacement and stented elephant trunk implantation were performed by using deep hypothermic circulatory arrest and antegrade selective cerebral perfusion in all cases. Urgent surgery underwent in 9 cases. The mean interval between the onset of aortic dissection and the accomplishment of surgery was (41.0 +/- 15.9) hours. Cardiopulmonary bypass time was (191 +/- 26) min, average cross clamp time was (134 +/- 31) min, and average deep hypothermic circulatory arrest time was (50.0 +/- 14.5) min. One patient died in hospital. The time stayed in ICU was 3 to 27 d. Mental disorder in 6 cases, hemi-paralysis in 1 case, amputation in 1 case, hemorrhage of anastomosis in 1 case, hemorrhage of alimentary tract in 1 case, and pleural effusion in 4 cases were recorded. Eleven cases were followed-up for 8 weeks to 36 months. There were no bending of the stents and no obstruction in the vascular prosthesis.No re-operation was needed. One case died 6 months postoperatively. Bentall operation combined with total arch replacement and stented elephant trunk implantation is safe and effective for serious Debakey I aortic dissecting aneurysm, while good organs protection and consummate cardiopulmonary bypass were taken.

  16. Osseointegration of zirconia implants: an SEM observation of the bone-implant interface.

    Science.gov (United States)

    Depprich, Rita; Zipprich, Holger; Ommerborn, Michelle; Mahn, Eduardo; Lammers, Lydia; Handschel, Jörg; Naujoks, Christian; Wiesmann, Hans-Peter; Kübler, Norbert R; Meyer, Ulrich

    2008-11-06

    The successful use of zirconia ceramics in orthopedic surgery led to a demand for dental zirconium-based implant systems. Because of its excellent biomechanical characteristics, biocompatibility, and bright tooth-like color, zirconia (zirconium dioxide, ZrO2) has the potential to become a substitute for titanium as dental implant material. The present study aimed at investigating the osseointegration of zirconia implants with modified ablative surface at an ultrastructural level. A total of 24 zirconia implants with modified ablative surfaces and 24 titanium implants all of similar shape and surface structure were inserted into the tibia of 12 Göttinger minipigs. Block biopsies were harvested 1 week, 4 weeks or 12 weeks (four animals each) after surgery. Scanning electron microscopy (SEM) analysis was performed at the bone implant interface. Remarkable bone attachment was already seen after 1 week which increased further to intimate bone contact after 4 weeks, observed on both zirconia and titanium implant surfaces. After 12 weeks, osseointegration without interposition of an interfacial layer was detected. At the ultrastructural level, there was no obvious difference between the osseointegration of zirconia implants with modified ablative surfaces and titanium implants with a similar surface topography. The results of this study indicate similar osseointegration of zirconia and titanium implants at the ultrastructural level.

  17. Short dental implants versus standard dental implants placed in the posterior jaws: A systematic review and meta-analysis.

    Science.gov (United States)

    Lemos, Cleidiel Aparecido Araujo; Ferro-Alves, Marcio Luiz; Okamoto, Roberta; Mendonça, Marcos Rogério; Pellizzer, Eduardo Piza

    2016-04-01

    The purpose of the present systematic review and meta-analysis was to compare short implants (equal or less than 8mm) versus standard implants (larger than 8mm) placed in posterior regions of maxilla and mandible, evaluating survival rates of implants, marginal bone loss, complications and prosthesis failures. This review has been registered at PROSPERO under the number CRD42015016588. Main search terms were used in combination: dental implant, short implant, short dental implants, short dental implants posterior, short dental implants maxilla, and short dental implants mandible. An electronic search for data published up until September/2015 was undertaken using the PubMed/Medline, Embase and The Cochrane Library databases. Eligibility criteria included clinical human studies, randomized controlled trials and/or prospective studies, which evaluated short implants in comparison to standard implants in the same study. The search identified 1460 references, after inclusion criteria 13 studies were assessed for eligibility. A total of 1269 patients, who had received a total of 2631 dental implants. The results showed that there was no significant difference of implants survival (P=.24; RR:1.35; CI: 0.82-2.22), marginal bone loss (P=.06; MD: -0.20; CI: -0.41 to 0.00), complications (P=.08; RR:0.54; CI: 0.27-1.09) and prosthesis failures (P=.92; RR:0.96; CI: 0.44-2.09). Short implants are considered a predictable treatment for posterior jaws. However, short implants with length less than 8 mm (4-7 mm) should be used with caution because they present greater risks to failures compared to standard implants. Short implants are frequently placed in the posterior area in order to avoid complementary surgical procedures. However, clinicians need to be aware that short implants with length less than 8mm present greater risk of failures. Copyright © 2016. Published by Elsevier Ltd.

  18. Marginal bone loss and dental implant failure may be increased in smokers.

    Science.gov (United States)

    Veitz-Keenan, Analia

    2016-03-01

    An electronic search was performed in PubMed, Web of Science and the Cochrane Central Register of Controlled Trials up to February 2015. References of included studies were also searched. No language restrictions were applied. Study selection: Prospective, retrospective and randomised clinical trials that compared marginal bone loss and failure rates between smokers and non-smokers. Implant failure was considered as total loss of the implant. Studies with patients who had periodontal disease prior to treatment or who had metabolic diseases were excluded. Two reviewers were involved in the research and screening process and disagreements were resolved by discussion. The quality of the studies was analysed using the Newcastle-Ottawa scale for non-randomised clinical trials. Data extracted from the studies included, when available: follow up period, number of subjects, smoking status, number of implants placed, implant system, implant length and diameter, healing period, antibiotics and mouth-rinse use, marginal bone loss, failure rate and drop-outs. For binary outcomes (implant failure) the estimate of the intervention effect was expressed in the form of an odds ratio (OR) with the confidence interval (CI) of 95%. For continuous outcomes (marginal bone loss) the average and standard deviation (SD) were used to calculate the standardised mean difference with a 95% CI. Meta-analysis was performed for studies with similar outcomes, I(2) a statistical test was used to express the heterogeneity among the studies. Publication bias was explored as well. A total of 15 observational studies were included in the review. The number of participants ranged from 60 to 1727 and the average age was 52.5 years. The follow-up period ranged from eight to 240 months. The total number of implants placed was 5840 in smokers and 14,683 in non-smokers. The Branemak system, (Noble Biocare AB, Goteborg, Sweden), was the most commonly used implant system. There was a statistically significant

  19. Total DNA of Glycyrrhiza uralensis transformed into Hansenula anomala by ion implantation:Preparing Glycyrrhizic acid in recombined yeasts

    International Nuclear Information System (INIS)

    Jin Xiang; Mao Peihong; Lu Jie; Ma Yuan

    2010-01-01

    Glycyrrhizic acid (GA) in Glycyrrhiza uralensis (G. uralensis) is physiologically active. In this study, the total DNA of wild G. uralensis was randomly transformed into Hansenula anomaly by implantation of low-energy Ar + and N + , to produce five recombinant yeast strains relating to biological synthesis of the GA or Glycyrrhetinic acid (GAs). After culturing in liquid medium for 96 h, the resultant GA, 18α-GAs and 18β-Gas were determined by reversed-phase high performance liquid chromatography (RP-HPLC), and the corresponding concentrations were 114.49, 0.56, and 0.81 mg·L -1 . After one hundred primers were analyzed with random amplified polymorphic DNA (RAPD), the seven different DNA fragments were produced by the N7059 strain of recombined yeasts, and, the polymerase chain reaction (PCR) verified that one of them came from the genome of G. uralensis, indicating a successful transfer of genetic information by ion implantation. (authors)

  20. Uniform implantation of CNTs on total activated carbon surfaces: a smart engineering protocol for commercial supercapacitor applications.

    Science.gov (United States)

    Jiang, Jian; Li, Linpo; Liu, Yani; Liu, Siyuan; Xu, Maowen; Zhu, Jianhui

    2017-04-07

    The main obstacles to building better supercapacitors are still trade-offs between energy and power parameters. To promote commercial supercapacitor behaviors, proper optimization toward electrode configurations/architectures may be a feasible and effective way. We herein propose a smart and reliable electrode engineering protocol, by in situ implantation of carbon nanotubes (CNTs) on total activated carbon (AC) surfaces via a mild chemical vapor deposition process at ∼550 °C, using nickel nitrate hydroxide (NNH) thin films and waste ethanol solvents as the catalyst and carbon sources, respectively. The direct and conformal growth of NNH layers onto carbonaceous scaffold guarantees the later uniform implantation of long and high-quality CNTs on total AC outer surfaces. Such fluffy and entangled CNTs preserve ionic diffusion channels, well connect neighboring ACs and function as superhighways for electrons transfer, endowing electrodes with outstanding capacitive behaviors including large output capacitances of ∼230 F g -1 in 1 M Na 2 SO 4 neutral solution and ∼502.5 F g -1 in 6 M KOH using Ni valence state variation, and very negligible capacity decay in long-term cycles. Furthermore, a full symmetric supercapacitor device of CNTs@ACs//CNTs@ACs has been constructed, capable of delivering both high specific energy and power densities (maximum values reaching up to ∼97.2 Wh kg -1 and ∼10.84 kW kg -1 ), which holds great potential in competing with current mainstream supercapacitors.

  1. A comparison of 500 prefilled textured saline breast implants versus 500 standard textured saline breast implants: is there a difference in deflation rates?

    Science.gov (United States)

    Stevens, W Grant; Hirsch, Elliot M; Stoker, David A; Cohen, Robert

    2006-06-01

    This study provides the first large-volume (1000 implant) comparison of the deflation rates of Poly Implant Prosthesis prefilled textured saline breast implants versus a control group of Mentor Siltex textured saline implants. A consecutive series of 500 Poly Implant Prosthesis prefilled textured saline breast implants was compared with a consecutive series of 500 Mentor Siltex breast implants. Each breast implant was evaluated for a 4-year period, and the annual deflation rate (number of deflations during a given year divided by the total number of implants) and cumulative deflation rate (cumulative total of deflations through a given year divided by the total number of implants) were recorded. Statistical significance was calculated using the Fisher's exact test at year 1 and the chi-square analysis at years 2 through 4. The cumulative deflation rates of the Poly Implant Prosthesis implants was as follows: year 1, 1.2 percent; year 2, 5.6 percent; year 3, 11.4 percent; and year 4, 15.4 percent. The cumulative deflation rates of the Mentor implants was: year 1, 0.2 percent; year 2, 0.6 percent; year 3, 1.6 percent; and year 4, 4.4 percent. At year 1, the difference between deflation rates was not statistically significant (Fisher's exact test, p > 0.05). However, at year 2 (chi-square, 13.29; p deflation rates of Poly Implant Prosthesis prefilled textured saline breast implants and Mentor Siltex breast implants at year 2, year 3, and year 4. After 4 years, the 15.56 percent cumulative deflation rate of Poly Implant Prosthesis implants was over 3.5 times higher than the 4.31 percent deflation rate of the Mentor Siltex implants. There may be several factors contributing to the higher deflation rate seen in Poly Implant Prosthesis implants, including possible in vitro deflation before implantation and silicone shell curing technique. Nevertheless, this statistically significant deflation difference must be taken into account when balancing the risks and benefits of

  2. Splenic implant preservation after conservation in lactated Ringer´s solution

    OpenAIRE

    MATOS FILHO, ARGOS SOARES DE; PETROIANU, ANDY; CARDOSO, VALBERT NASCIMENTO; VIDIGAL, PAULA VIEIRA TEIXEIRA

    2018-01-01

    ABSTRACT Objective: to evaluate the morphology and function of autogenous splenic tissue implanted in the greater omentum, 24 hours after storage in Ringer-lactate solution. Methods: we divided 35 male rats into seven groups (n=5): Group 1: no splenectomy; Group 2: total splenectomy without implant; Group 3: total splenectomy and immediate autogenous implant; Group 4: total splenectomy, preservation of the spleen in Ringer-lactate at room temperature, then sliced and implanted; Group 5: tot...

  3. Recall management of patients with Rofil Medical breast implants.

    Science.gov (United States)

    Schott, Sarah; Bruckner, Thomas; Golatta, Michael; Wallwiener, Markus; Küffner, Livia; Mayer, Christine; Paringer, Carmen; Domschke, Christoph; Blumenstein, Maria; Schütz, Florian; Sohn, Christof; Heil, Joerg

    2014-07-01

    Some Rofil Medical breast implants are relabelled Poly Implant Prothèse (PIP) implants, and it is recommended that Rofil implants be managed in the same way as PIP implants. We report the results of a systematic recall of patients who had received Rofil implants. All patients who received Rofil implants at our centre were identified and invited for specialist consultation. In patients who opted for explantation, preoperative and intraoperative work-up was performed in accordance with national guidelines and analysed. In cases suspicious for rupture, an MRI scan was performed. Two-hundred and twenty-five patients (average age 56; range 28-80) received a total of 321 Rofil implants an average of 5.8 (range 1-11) years previously, 225/321 (70%) implants were used for reconstruction after breast cancer. A total of 43 implants were removed prior to 2011, mainly due to capsular contracture (CC). A total of 188 patients were still affected at the time of recall. Of the 188 patients, 115 (61%) attended for specialist consultation, of which 50 (44%) requested immediate implant removal. To date, 72 of 115 (63%) women attending consultation (38% of all affected) have chosen explantation, 66 of 72 (92%) opting for new implants. Of the 108 explanted implants, 25 (23%) had capsular rupture and 57 (53%) had implant bleeding. Preoperative clinical assessment was unreliable for predicting CC or rupture. The majority of patients attended for consultation and requested explantation. The quality of the explanted Rofil implants was comparable to PIP implants, with a higher rupture prevalence compared with other, non-affected implants. Nevertheless, the acceptance of breast implants for reimplantation remained high. Copyright © 2014 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  4. Asymmetric extractions in a patient with a hopeless maxillary central incisor, followed by treatment with mini-implant anchorage.

    Science.gov (United States)

    Jung, Min-Ho

    2018-05-01

    Premolar extraction is 1 option for treatment of patients with malocclusion and severe crowding or protrusion. When the patient has missing or hopeless teeth other than premolars, it is possible to consider removal of those teeth to use the space to decrease crowding. A 15-year-old girl sought treatment for severe crowding. She had already lost her maxillary right first premolar as a result of caries 1 year previously and had a hopeless maxillary right central incisor. Her mandibular left first molar still caused discomfort even after endodontic treatment. Extractions of the maxillary right central incisor and mandibular right first premolar and left first molar were chosen to resolve the occlusion problems. Orthodontic mini-implants were placed to translocate the maxillary left central incisor across the midpalatal suture to use the space in the maxillary right quadrant to relieve the crowding. Although a different extraction option was used in each quadrant, the final occlusion was acceptable. After debonding, porcelain crowns were placed on the anterior teeth to improve esthetics. The treatment result remained stable after 2 years of retention. Copyright © 2018 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.

  5. PAIN RELIEF MEDIATED BY IMPLANTABLE DRUG-DELIVERY DEVICES

    NARCIS (Netherlands)

    HOEKSTRA, A

    Various totally implantable drug delivery systems from single access ports to micropumps are now available for administration of repeated boluses, and continuous or programmable infusions. In this respect, emphasis is given to a relatively cheap, totally implantable system for self-administering

  6. Development and evaluation of totally implantable ventricular assist system using a vibrating flow pump and transcutaneous energy transmission system with amorphous fibers.

    Science.gov (United States)

    Yambe, T; Hashimoto, H; Kobayashi, S; Sonobe, T; Naganuma, S; Nanka, S S; Matsuki, H; Yoshizawa, M; Tabayashi, K; Takayasu, H; Takeda, H; Nitta, S

    1997-01-01

    We have developed a vibrating flow pump (VFP) that can generate oscillated blood flow with a relatively high frequency (10-50 Hz) for a totally implantable ventricular assist system (VAS). To evaluate the newly developed VAS, left heart bypasses, using the VFP, were performed in chronic animal experiments. Hemodynamic parameters were recorded in a data recorder in healthy adult goats during an awake condition and analyzed in a personal computer system through an alternating-direct current converter. Basic performance of the total system with a transcutaneous energy transmission system were satisfactory. During left ventricular assistance with the VFP, Mayer wave fluctuations of hemodynamics were decreased in the power spectrum, the fractal dimensions of the hemodynamics were significantly decreased, and peripheral vascular resistance was significantly decreased. These results suggest that cardiovascular regulatory nonlinear dynamics, which mediate the hemodynamics, may be affected by left ventricular bypass with oscillated flow. The decreased power of the Mayer wave in the spectrum caused the limit cycle attractor of the hemodynamics and decreased peripheral resistance. These results suggest that this newly developed VAS is useful for the totally implantable system with unique characteristics that can control hemodynamic properties.

  7. Splenic implant preservation after conservation in lactated Ringer´s solution.

    Science.gov (United States)

    Matos Filho, Argos Soares DE; Petroianu, Andy; Cardoso, Valbert Nascimento; Vidigal, Paula Vieira Teixeira

    2018-01-01

    to evaluate the morphology and function of autogenous splenic tissue implanted in the greater omentum, 24 hours after storage in Ringer-lactate solution. we divided 35 male rats into seven groups (n=5): Group 1: no splenectomy; Group 2: total splenectomy without implant; Group 3: total splenectomy and immediate autogenous implant; Group 4: total splenectomy, preservation of the spleen in Ringer-lactate at room temperature, then sliced ​​and implanted; Group 5: total splenectomy, ​​spleen sliced and preserved in Ringer-lactate at room temperature before implantation; Group 6: total splenectomy with preservation of the spleen in Ringer-lactate at 4°C and then sliced ​​and implanted; Group 7: total splenectomy and the spleen sliced for preservation in Ringer-lactate at 4°C before implantation. After 90 days, we performed scintigraphic studies with Tc99m-colloidal tin (liver, lung, spleen or implant and clot), haematological exams (erythrogram, leucometry, platelets), biochemical dosages (protein electrophoresis) and anatomopathological studies. regeneration of autogenous splenic implants occurred in the animals of the groups with preservation of the spleen at 4ºC. The uptake of colloidal tin was higher in groups 1, 3, 6 and 7 compared with the others. There was no difference in hematimetric values ​​in the seven groups. Protein electrophoresis showed a decrease in the gamma fraction in the group of splenectomized animals in relation to the operated groups. the splenic tissue preserved in Ringer-lactate solution at 4ºC maintains its morphological structure and allows functional recovery after being implanted on the greater omentum.

  8. Splenic implant preservation after conservation in lactated Ringer´s solution

    Directory of Open Access Journals (Sweden)

    ARGOS SOARES DE MATOS FILHO

    2018-02-01

    Full Text Available ABSTRACT Objective: to evaluate the morphology and function of autogenous splenic tissue implanted in the greater omentum, 24 hours after storage in Ringer-lactate solution. Methods: we divided 35 male rats into seven groups (n=5: Group 1: no splenectomy; Group 2: total splenectomy without implant; Group 3: total splenectomy and immediate autogenous implant; Group 4: total splenectomy, preservation of the spleen in Ringer-lactate at room temperature, then sliced and implanted; Group 5: total splenectomy, spleen sliced and preserved in Ringer-lactate at room temperature before implantation; Group 6: total splenectomy with preservation of the spleen in Ringer-lactate at 4°C and then sliced and implanted; Group 7: total splenectomy and the spleen sliced for preservation in Ringer-lactate at 4°C before implantation. After 90 days, we performed scintigraphic studies with Tc99m-colloidal tin (liver, lung, spleen or implant and clot, haematological exams (erythrogram, leucometry, platelets, biochemical dosages (protein electrophoresis and anatomopathological studies. Results: regeneration of autogenous splenic implants occurred in the animals of the groups with preservation of the spleen at 4ºC. The uptake of colloidal tin was higher in groups 1, 3, 6 and 7 compared with the others. There was no difference in hematimetric values in the seven groups. Protein electrophoresis showed a decrease in the gamma fraction in the group of splenectomized animals in relation to the operated groups. Conclusion: the splenic tissue preserved in Ringer-lactate solution at 4ºC maintains its morphological structure and allows functional recovery after being implanted on the greater omentum.

  9. The Use of Ultrasound to Improve Axillary Vein Access and Minimize Complications during Pacemaker Implantation.

    Science.gov (United States)

    Esmaiel, Abdullah; Hassan, Jeremy; Blenkhorn, Fay; Mardigyan, Vartan

    2016-05-01

    The Agency for Healthcare Research and Quality in the United States recommends the use of ultrasound (US) for central venous access to improve patient outcomes. However, in a recent publication, US is still underutilized for axillary vein access during pacemaker implantation. We sought to describe a technique for US-guided axillary vein access during pacemaker implantation and to report complication rates and success rate. Retrospective data collection included success rate and complications on all pacemaker implants by one operator since implementing the systematic use of US at our institution, from November 2012 to January 2015. For the last 59 cases, data were collected prospectively to include time of venous access and number of attempts. A total of 403 consecutive patients were included in the analysis. Two leads were implanted in 255 cases and one lead was implanted in 148 cases. The rate of successful US-guided access was 99.25%. There were no access-related complications. The average number of venipuncture attempts was 1.18 per patient. The average time to obtain venous access was 2.24 minutes including the time to apply the sterile US sleeve. The described technique has the potential to improve the success rate of axillary vein access and minimize complications during pacemaker implantation. ©2016 Wiley Periodicals, Inc.

  10. Effect of implant position, angulation, and attachment height on peri-implant bone stress associated with mandibular two-implant overdentures: a finite element analysis.

    Science.gov (United States)

    Hong, Hae Ryong; Pae, Ahran; Kim, Yooseok; Paek, Janghyun; Kim, Hyeong-Seob; Kwon, Kung-Rock

    2012-01-01

    The aim of this study was to analyze and compare the level and distribution of peri-implant bone stresses associated with mandibular two-implant overdentures with different implant positions. Mathematical models of mandibles and overdentures were designed using finite element analysis software. Two intraosseous implants and ball attachment systems were placed in the interforaminal region. The overdenture, which was supported by the two implants, was designed to withstand bilateral and unilateral vertical masticatory loads (total 100 N). In all, eight types of models, which differed according to assigned implant positions, height of attachments, and angulation, were tested: MI (model with implants positioned in the lateral incisor sites), MC (implants in canine sites), MP (implants in premolar sites), MI-Hi (greater height of attachments), MC-M (canine implants placed with mesial inclination), MC-D (canine implants placed with distal inclination), MC-B (canine implants placed with buccal inclination), and MC-L (canine implants placed with lingual inclination). Peri-implant bone stress levels associated with overdentures retained by lateral incisor implants resulted in the lowest stress levels and the highest efficiency in distributing peri-implant stress. MI-Hi showed increased stress levels and decreased efficiency in stress distribution. As the implants were inclined, stress levels increased and the efficiency of stress distribution decreased. Among the inclined models, MC-B showed the lowest stress level and best efficiency in stress distribution. The lowest stress and the best stability of implants in mandibular two-implant overdentures were obtained when implants were inserted in lateral incisor areas with shorter attachments and were placed parallel to the long axes of the teeth.

  11. Comparative silicone breast implant evaluation using mammography, sonography, and magnetic resonance imaging: experience with 59 implants.

    Science.gov (United States)

    Ahn, C Y; DeBruhl, N D; Gorczyca, D P; Shaw, W W; Bassett, L W

    1994-10-01

    With the current controversy regarding the safety of silicone implants, the detection and evaluation of implant rupture are causing concern for both plastic surgeons and patients. Our study obtained comparative value analysis of mammography, sonography, and magnetic resonance imaging (MRI) in the detection of silicone implant rupture. Twenty-nine symptomatic patients (total of 59 silicone implants) were entered into the study. Intraoperative findings revealed 21 ruptured implants (36 percent). During physical examination, a positive "squeeze test" was highly suggestive of implant rupture. Mammograms were obtained of 51 implants (sensitivity 11 percent, specificity 89 percent). Sonography was performed on 57 implants (sensitivity 70 percent, specificity 92 percent). MRI was performed on 55 implants (sensitivity 81 percent, specificity 92 percent). Sonographically, implant rupture is demonstrated by the "stepladder sign." Double-lumen implants may appear as false-positive results for rupture on sonography. On MRI, the "linguine sign" represents disrupted fragments of a ruptured implant. The most reliable imaging modality for implant rupture detection is MRI, followed by sonogram. Mammogram is the least reliable. Our study supports the clinical indication and diagnostic value of sonogram and MRI in the evaluation of symptomatic breast implant patients.

  12. Immediate implant placement into fresh extraction sockets versus delayed implants into healed sockets: A systematic review and meta-analysis.

    Science.gov (United States)

    Mello, C C; Lemos, C A A; Verri, F R; Dos Santos, D M; Goiato, M C; Pellizzer, E P

    2017-09-01

    The aim of this systematic review and meta-analysis was to compare the survival rate of the implants and the peri-implant tissue changes associated with implants inserted in fresh extraction sockets and those inserted in healed sockets. This review has been registered at PROSPERO under the number CRD42016043309. A systematic search was conducted by two reviewers independently in the databases PubMed/MEDLINE, Embase, and the Cochrane Library using different search terms; articles published until November 2016 were searched for. The searches identified 30 eligible studies. A total of 3,049 implants were installed in a total of 1,435 patients with a mean age of 46.68 years and a minimum of 6 months of follow-up. The survival rate of delayed implants (98.38%) was significantly greater than immediate implants (95.21%) (p=.001). For the marginal bone loss (p=.32), implant stability quotients values (p=.44), and pocket probing depth (p=.94) there was no significant difference between the analysed groups. The immediate implants placed in fresh sockets should be performed with caution because of the significantly lower survival rates than delayed implants inserted in healed sockets. Copyright © 2017 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  13. The surgical viability and radiological monitoring of brain implants of bioactive micro-seeds in an animal model

    International Nuclear Information System (INIS)

    Silva, Giane X.O.; Campos, Tarcisio Passos Ribeiro de; Siqueira, Savio Lana; Maciel, Marcelo B.

    2005-01-01

    The interstitial implant is a therapeutic modality in brachytherapy of the head and neck. Presently, the seeds implanted in tumors in the central nervous system are metallic I-125. After the full emission of the radionuclide, the seed remains inert in the implanted area. Bioactive ceramic seeds have been prepared for this research group incorporating Sm-152 to be active in Sm-153. The main goal of the present study is the development of a the surgical technique for implanting the biodegradable radioactive micro-seeds in the brains of rabbits, as well as the observation of the clinical reactions of the animal after implantation of two sets of three seeds. The surgical procedure consisted of performing two separate perforations 10 mm from each other in the skull, permitting the implantation of two groups of three seeds, totaling six seeds. The results of the pilot study showed the effectiveness of the surgical procedure and of the biocompatibility of the seeds and the lack of presence of adverse reactions, functional sequels, or inflammation in a follow up 50 days post-surgery. Such seeds of reduced volume, 0.2 x 1.6 mm, could be monitored by computerized tomography 30 days after implanting. (author)

  14. The KFKI 150 kV ion-implanter

    International Nuclear Information System (INIS)

    Pasztor, E.

    1976-09-01

    The description of the ion-implanter of 150 keV maximum energy designed and built in the Central Research Institute for Physics, Budapest is given. The implanter fulfils all technological and safety requirements of the industry. In addition to B,P and As other elements up to mass-number 76 can also be implanted by help of the Danfysik 911 type ion source. The 3x10 -6 Torr operational pressure is provided by three turbomolecular pumps. The maximum dose is 1 μCb/cm 2 min and to ensure uniformity of the implantation on the 100x105 mm 2 target area the ion beam is swept electrostatically. According to the testing experiments the inhomogenity can be taken to be +-1.3%. (Sz.N.Z.)

  15. Automated treatment planning engine for prostate seed implant brachytherapy

    International Nuclear Information System (INIS)

    Yu Yan; Zhang, J.B.Y.; Brasacchio, Ralph A.; Okunieff, Paul G.; Rubens, Deborah J.; Strang, John G.; Soni, Arvind; Messing, Edward M.

    1999-01-01

    Purpose: To develop a computer-intelligent planning engine for automated treatment planning and optimization of ultrasound- and template-guided prostate seed implants. Methods and Materials: The genetic algorithm was modified to reflect the 2D nature of the implantation template. A multi-objective decision scheme was used to rank competing solutions, taking into account dose uniformity and conformity to the planning target volume (PTV), dose-sparing of the urethra and the rectum, and the sensitivity of the resulting dosimetry to seed misplacement. Optimized treatment plans were evaluated using selected dosimetric quantifiers, dose-volume histogram (DVH), and sensitivity analysis based on simulated seed placement errors. These dosimetric planning components were integrated into the Prostate Implant Planning Engine for Radiotherapy (PIPER). Results: PIPER has been used to produce a variety of plans for prostate seed implants. In general, maximization of the minimum peripheral dose (mPD) for given implanted total source strength tended to produce peripherally weighted seed patterns. Minimization of the urethral dose further reduced the loading in the central region of the PTV. Isodose conformity to the PTV was achieved when the set of objectives did not reflect seed positioning uncertainties; the corresponding optimal plan generally required fewer seeds and higher source strength per seed compared to the manual planning experience. When seed placement uncertainties were introduced into the set of treatment planning objectives, the optimal plan tended to reach a compromise between the preplanned outcome and the likelihood of retaining the preferred outcome after implantation. The reduction in the volatility of such seed configurations optimized under uncertainty was verified by sensitivity studies. Conclusion: An automated treatment planning engine incorporating real-time sensitivity analysis was found to be a useful tool in dosimetric planning for prostate

  16. Translation of First North American 50 and 70 cc Total Artificial Heart Virtual and Clinical Implantations: Utility of 3D Computed Tomography to Test Fit Devices.

    Science.gov (United States)

    Ferng, Alice S; Oliva, Isabel; Jokerst, Clinton; Avery, Ryan; Connell, Alana M; Tran, Phat L; Smith, Richard G; Khalpey, Zain

    2017-08-01

    Since the creation of SynCardia's 50 cc Total Artificial Hearts (TAHs), patients with irreversible biventricular failure now have two sizing options. Herein, a case series of three patients who have undergone successful 50 and 70 cc TAH implantation with complete closure of the chest cavity utilizing preoperative "virtual implantation" of different sized devices for surgical planning are presented. Computed tomography (CT) images were used for preoperative planning prior to TAH implantation. Three-dimensional (3D) reconstructions of preoperative chest CT images were generated and both 50 and 70 cc TAHs were virtually implanted into patients' thoracic cavities. During the simulation, the TAHs were projected over the native hearts in a similar position to the actual implantation, and the relationship between the devices and the atria, ventricles, chest wall, and diaphragm were assessed. The 3D reconstructed images and virtual modeling were used to simulate and determine for each patient if the 50 or 70 cc TAH would have a higher likelihood of successful implantation without complications. Subsequently, all three patients received clinical implants of the properly sized TAH based on virtual modeling, and their chest cavities were fully closed. This virtual implantation increases our confidence that the selected TAH will better fit within the thoracic cavity allowing for improved surgical outcome. Clinical implantation of the TAHs showed that our virtual modeling was an effective method for determining the correct fit and sizing of 50 and 70 cc TAHs. © 2016 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  17. Peri-implant stress correlates with bone and cement morphology: Micro-FE modeling of implanted cadaveric glenoids.

    Science.gov (United States)

    Wee, Hwabok; Armstrong, April D; Flint, Wesley W; Kunselman, Allen R; Lewis, Gregory S

    2015-11-01

    Aseptic loosening of cemented joint replacements is a complex biological and mechanical process, and remains a clinical concern especially in patients with poor bone quality. Utilizing high resolution finite element analysis of a series of implanted cadaver glenoids, the objective of this study was to quantify relationships between construct morphology and resulting mechanical stresses in cement and trabeculae. Eight glenoid cadavers were implanted with a cemented central peg implant. Specimens were imaged by micro-CT, and subject-specific finite element models were developed. Bone volume fraction, glenoid width, implant-cortex distance, cement volume, cement-cortex contact, and cement-bone interface area were measured. Axial loading was applied to the implant of each model and stress distributions were characterized. Correlation analysis was completed across all specimens for pairs of morphological and mechanical variables. The amount of trabecular bone with high stress was strongly negatively correlated with both cement volume and contact between the cement and cortex (r = -0.85 and -0.84, p implant-cortex distance. Contact between the cement and underlying cortex may dramatically reduce trabecular bone stresses surrounding the cement, and this contact depends on bone shape, cement amount, and implant positioning. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  18. Comparison of external and internal implant-abutment connections for implant supported prostheses. A systematic review and meta-analysis.

    Science.gov (United States)

    Lemos, Cleidiel Aparecido Araujo; Verri, Fellippo Ramos; Bonfante, Estevam Augusto; Santiago Júnior, Joel Ferreira; Pellizzer, Eduardo Piza

    2018-03-01

    The systematic review and meta-analysis aimed to answer the PICO question: "Do patients that received external connection implants show similar marginal bone loss, implant survival and complication rates as internal connection implants?". Meta-analyses of marginal bone loss, survival rates of implants and complications rates were performed for the included studies. Study eligibility criteria included (1) randomized controlled trials (RCTs) and/or prospective, (2) studies with at least 10 patients, (3) direct comparison between connection types and (4) publications in English language. The Cochrane risk of bias tool was used to assess the quality and risk of bias in RCTs, while Newcastle-Ottawa scale was used for non-RCTs. A comprehensive search strategy was designed to identify published studies on PubMed/MEDLINE, Scopus, and The Cochrane Library databases up to October 2017. The search identified 661 references. Eleven studies (seven RCTs and four prospective studies) were included, with a total of 530 patients (mean age, 53.93 years), who had received a total of 1089 implants (461 external-connection and 628 internal-connection implants). The internal-connection implants exhibited lower marginal bone loss than external-connection implants (PInternal connections had lower marginal bone loss when compared to external connections. However, the implant-abutment connection had no influence on the implant's survival and complication rates. Based on the GRADE approach the evidence was classified as very low to moderate due to the study design, inconsistency, and publication bias. Thus, future research is highly encouraged. Internal connection implants should be preferred over external connection implants, especially when different risk factors that may contribute to increased marginal bone loss are present. Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. Body Implanted Medical Device Communications

    Science.gov (United States)

    Yazdandoost, Kamya Yekeh; Kohno, Ryuji

    The medical care day by day and more and more is associated with and reliant upon concepts and advances of electronics and electromagnetics. Numerous medical devices are implanted in the body for medical use. Tissue implanted devices are of great interest for wireless medical applications due to the promising of different clinical usage to promote a patient independence. It can be used in hospitals, health care facilities and home to transmit patient measurement data, such as pulse and respiration rates to a nearby receiver, permitting greater patient mobility and increased comfort. As this service permits remote monitoring of several patients simultaneously it could also potentially decrease health care costs. Advancement in radio frequency communications and miniaturization of bioelectronics are supporting medical implant applications. A central component of wireless implanted device is an antenna and there are several issues to consider when designing an in-body antenna, including power consumption, size, frequency, biocompatibility and the unique RF transmission challenges posed by the human body. The radiation characteristics of such devices are important in terms of both safety and performance. The implanted antenna and human body as a medium for wireless communication are discussed over Medical Implant Communications Service (MICS) band in the frequency range of 402-405MHz.

  20. Randomized study on the effect of single-implant versus two-implant retained overdentures on implant loss and muscle activity: a 12-month follow-up report.

    Science.gov (United States)

    Alqutaibi, A Y; Kaddah, A F; Farouk, M

    2017-06-01

    The objective was to evaluate and compare single- and two-implant retained overdentures for the rehabilitation of the edentulous mandible. Fifty-six edentulous subjects were eligible for inclusion. Using a random sampling system, a single implant or two implants were placed in the mandible. After 3 months, locator attachments were connected to the implants and the denture delivered with the retentive components incorporated in the denture base. Implant failure and muscle activity were evaluated at the 3-, 6-, and 12-month follow-up examinations. The study sample comprised 56 patients (32 male, 24 female), with a mean age of 58.2 years. A total of 84 implants were placed (28 in the single-implant group and 56 in the two-implant group). All patients completed the 12 months of follow-up. No significant differences were found between subjects in the two groups with respect to implant failure. With regard to improvements in muscle activity, the two-implant group showed statistically significant but perhaps not clinically important differences. Single-implant mandibular overdentures may be suggested as an alternative treatment modality for the rehabilitation of edentulous patients who cannot afford the cost of a two-implant overdenture. Copyright © 2017 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  1. Modes of failure of Osteonics constrained tripolar implants: a retrospective analysis of forty-three failed implants.

    Science.gov (United States)

    Guyen, Olivier; Lewallen, David G; Cabanela, Miguel E

    2008-07-01

    The Osteonics constrained tripolar implant has been one of the most commonly used options to manage recurrent instability after total hip arthroplasty. Mechanical failures were expected and have been reported. The purpose of this retrospective review was to identify the observed modes of failure of this device. Forty-three failed Osteonics constrained tripolar implants were revised at our institution between September 1997 and April 2005. All revisions related to the constrained acetabular component only were considered as failures. All of the devices had been inserted for recurrent or intraoperative instability during revision procedures. Seven different methods of implantation were used. Operative reports and radiographs were reviewed to identify the modes of failure. The average time to failure of the forty-three implants was 28.4 months. A total of five modes of failure were observed: failure at the bone-implant interface (type I), which occurred in eleven hips; failure at the mechanisms holding the constrained liner to the metal shell (type II), in six hips; failure of the retaining mechanism of the bipolar component (type III), in ten hips; dislocation of the prosthetic head at the inner bearing of the bipolar component (type IV), in three hips; and infection (type V), in twelve hips. The mode of failure remained unknown in one hip that had been revised at another institution. The Osteonics constrained tripolar total hip arthroplasty implant is a complex device involving many parts. We showed that failure of this device can occur at most of its interfaces. It would therefore appear logical to limit its application to salvage situations.

  2. Economic Evaluation of Implant-Supported Overdentures in Edentulous Patients: A Systematic Review.

    Science.gov (United States)

    Zhang, Qi; Jin, Xin; Yu, Mengliu; Ou, Guoming; Matsui, Hiroyuki; Liang, Xing; Sasaki, Keiichi

    Edentulous patients benefit significantly from implant-supported overdenture prostheses. The purpose of this systematic review was to evaluate the cost-effectiveness of implant-supported overdentures (IODs) for edentulous patients. The search was limited to studies written in English and included an electronic and manual search through MEDLINE (Ovid, 1946 to November 2015), Embase (Ovid, 1966 to November 2015), Cochrane Central Register of Controlled Trials (CENTRAL) (to November 2015), and PubMed (to November 2015). Two investigators extracted the data and assessed the studies independently. No meta-analysis was conducted due to the high heterogeneity within the literature. Of the initial 583 selected articles, 10 studies involving 802 participants were included. Of these, 6 studies had a high risk of bias and the rest had an unclear risk of bias. Implant-supported prostheses were more cost-effective when compared to conventional dentures and fixed implant-supported prostheses. Overdentures supported by two implants and magnet attachment were reported as cost-effective. Implant-supported overdentures are a cost-effective treatment for edentulous patients. More clinical studies with appropriate scientific vigor are required to further assess the cost-effectiveness of implant-supported overdentures.

  3. Effects of pore size, implantation time, and nano-surface properties on rat skin ingrowth into percutaneous porous titanium implants.

    Science.gov (United States)

    Farrell, Brad J; Prilutsky, Boris I; Ritter, Jana M; Kelley, Sean; Popat, Ketul; Pitkin, Mark

    2014-05-01

    The main problem of percutaneous osseointegrated implants is poor skin-implant integration, which may cause infection. This study investigated the effects of pore size (Small, 40-100 μm and Large, 100-160 μm), nanotubular surface treatment (Nano), and duration of implantation (3 and 6 weeks) on skin ingrowth into porous titanium. Each implant type was percutaneously inserted in the back of 35 rats randomly assigned to seven groups. Implant extrusion rate was measured weekly and skin ingrowth into implants was determined histologically after harvesting implants. It was found that all three types of implants demonstrated skin tissue ingrowth of over 30% (at week 3) and 50% (at weeks 4-6) of total implant porous area under the skin; longer implantation resulted in greater skin ingrowth (p skin integration with the potential for a safe seal. Copyright © 2013 Wiley Periodicals, Inc.

  4. The Monorail Technique to Overcome Difficult Anatomical Course During Implantation of Central Venous Port via the Left Internal Jugular Vein

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Eu Hyun, E-mail: doorihyun6@gmail.com; Oh, Jung Suk; Chun, Ho Jong; Lee, Hae Giu; Choi, Byung Gil, E-mail: cbg@catholic.ac.kr [The Catholic University of Korea, Department of Radiology, Seoul St. Mary’s Hospital (Korea, Republic of)

    2017-03-15

    PurposeThe study aimed to introduce a monorail technique to overcome difficult anatomical course via left internal jugular vein in implantable port insertion.MethodsFrom 2007 to 2016, a total of 9346 patients were referred for implantable port insertion in our interventional unit, among which 79 cases were requested to insert on the left side. Our monorail technique was applied only when the technical challenge of the catheter tip entering the azygos vein instead of the superior vena cava occurred (n = 7). The technique consists of puncturing at the distal tip of the port catheter with a 21-gauge micropuncture needle and advancing a 0.018-in. hair-wire to guide and provide support for pre-assembled port.ResultsThe monorail technique was performed in seven patients and all but one case were technically successful, showing a technical success rate of 85.7%. There were no immediate or delayed complications.ConclusionsThe monorail technique is helpful to overcome the difficult anatomical course via left internal jugular vein in implantable port insertion.

  5. The Monorail Technique to Overcome Difficult Anatomical Course During Implantation of Central Venous Port via the Left Internal Jugular Vein

    International Nuclear Information System (INIS)

    Kim, Eu Hyun; Oh, Jung Suk; Chun, Ho Jong; Lee, Hae Giu; Choi, Byung Gil

    2017-01-01

    PurposeThe study aimed to introduce a monorail technique to overcome difficult anatomical course via left internal jugular vein in implantable port insertion.MethodsFrom 2007 to 2016, a total of 9346 patients were referred for implantable port insertion in our interventional unit, among which 79 cases were requested to insert on the left side. Our monorail technique was applied only when the technical challenge of the catheter tip entering the azygos vein instead of the superior vena cava occurred (n = 7). The technique consists of puncturing at the distal tip of the port catheter with a 21-gauge micropuncture needle and advancing a 0.018-in. hair-wire to guide and provide support for pre-assembled port.ResultsThe monorail technique was performed in seven patients and all but one case were technically successful, showing a technical success rate of 85.7%. There were no immediate or delayed complications.ConclusionsThe monorail technique is helpful to overcome the difficult anatomical course via left internal jugular vein in implantable port insertion.

  6. The Monorail Technique to Overcome Difficult Anatomical Course During Implantation of Central Venous Port via the Left Internal Jugular Vein.

    Science.gov (United States)

    Kim, Eu Hyun; Oh, Jung Suk; Chun, Ho Jong; Lee, Hae Giu; Choi, Byung Gil

    2017-03-01

    The study aimed to introduce a monorail technique to overcome difficult anatomical course via left internal jugular vein in implantable port insertion. From 2007 to 2016, a total of 9346 patients were referred for implantable port insertion in our interventional unit, among which 79 cases were requested to insert on the left side. Our monorail technique was applied only when the technical challenge of the catheter tip entering the azygos vein instead of the superior vena cava occurred (n = 7). The technique consists of puncturing at the distal tip of the port catheter with a 21-gauge micropuncture needle and advancing a 0.018-in. hair-wire to guide and provide support for pre-assembled port. The monorail technique was performed in seven patients and all but one case were technically successful, showing a technical success rate of 85.7%. There were no immediate or delayed complications. The monorail technique is helpful to overcome the difficult anatomical course via left internal jugular vein in implantable port insertion.

  7. Complications after implantation of subcutaneous central venous ports (PowerPortⓇ

    Directory of Open Access Journals (Sweden)

    Takatoshi Nakamura

    2017-05-01

    Conclusion: PowerPort is a multifunctional port. Benign disease was a risk factor for postoperative complications. Because many types of subcutaneously implanted ports are used in our hospital, we had to inform the hospital staff about the functions of PowerPort.

  8. Iris-fixated phakic intraocular lens implantation to correct myopia and a predictive model of endothelial cell loss.

    Science.gov (United States)

    Bouheraoua, Nacim; Bonnet, Clemence; Labbé, Antoine; Sandali, Otman; Lecuen, Nicolas; Ameline, Barbara; Borderie, Vincent; Laroche, Laurent

    2015-11-01

    To report long-term results of Artisan phakic intraocular lens (pIOL) to correct myopia and to propose a model predicting endothelial cell loss after pIOL implantation. Quinze-Vingts National Ophthalmology Hospital, Paris, France. Retrospective, interventional case series. Uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), and central endothelial cell count (ECC) were determined before and at yearly intervals up to 5 years after pIOL implantation. Linear model analysis was performed to present a model that describes endothelial cell loss as a linear decrease and an additional decrease depending on postoperative loss. A total of 49 patients (68 eyes) implanted with pIOLs from January 2000 to January 2009 were evaluated. The mean preoperative and final spherical equivalent (SE) were -13 ± 4.10 and -0.75 ± 0.74 diopters (D), respectively. The mean preoperative and final central ECC were 2629 ± 366 and 2250 ± 454 cells/mm(2), respectively. There were no intraoperative complications for any of the eyes. One eye required surgery for repositioning the pIOL, and 1 eye required pIOL exchange for postoperative refractive error. The model predicted that for patients with preoperative ECC of 3000, 2500, and 2000 cells/mm(2), a critical ECC of 1500 cells/mm(2) will be reached at 39, 28, and 15 years after implantation, respectively. Implantation of the pIOL was an effective and stable procedure after 5 years of follow-up. The presented model predicted EC loss after pIOL implantation, which can assist ophthalmologists in patient selection and follow-up. The authors report no conflict of interest. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  9. Evaluation of stress patterns produced by implant-retained overdentures and implant-retained fixed partial denture.

    Science.gov (United States)

    Mazaro, José Vitor Quinelli; Filho, Humberto Gennari; Vedovatto, Eduardo; Pellizzer, Eduardo Piza; Rezende, Maria Cristina Rosifini Alves; Zavanelli, Adriana Cristina

    2011-11-01

    The purposes of this study were to photoelastically measure the biomechanical behavior of 4 implants retaining different cantilevered bar mandibular overdenture designs and to compare a fixed partial denture (FPD). A photoelastic model of a human edentulous mandible was fabricated, which contained 4 screw-type implants (3.75 × 10 mm) embedded in the parasymphyseal area. An FPD and 3 overdenture designs with the following attachments were evaluated: 3 plastic Hader clips, 1 Hader clip with 2 posterior resilient cap attachments, and 3 ball/O-ring attachments. Vertical occlusal forces of 100 N were applied between the central incisor and unilaterally to the right and left second premolars and second molars. Stresses that developed in the supporting structure were monitored photoelastically and recorded photographically. The results showed that the anterior loading, the overdenture with 3 plastic Hader clips, displayed the largest stress concentration at the medium implant. With premolar loading, the FPD and overdenture with 3 plastic Hader clips displayed the highest stresses to the ipsilateral terminal implant. With molar loading, the overdenture with 3 ball/O-ring attachments displayed the most uniform stress distribution in the posterior edentulous ridge, with less overloading in the terminal implant. It was concluded that vertical forces applied to the bar-clip overdenture and FPD created immediate stress patterns of greater magnitude and concentration on the ipsilateral implants, whereas the ball/O-ring attachments transferred minimal stress to the implants. The increased cantilever in the FPD caused the highest stresses to the terminal implant.

  10. Are short implants in the mandible safe?

    Directory of Open Access Journals (Sweden)

    Sergio Henrique Gonçalves Motta

    2009-10-01

    Full Text Available Objective: To analyze the importance of bioengineering and the improvement in surgical techniques demonstrated by the rates attained of the prevalence of successful placement of dental implants in the posterior region of the mandible, in D3 bone quality in patients between the ages of 52 and 60 years, with dentures fixed on 8.5 mm implants. Methods: The statistical data for this retrospective study were collected at the Post-Graduation Center of the Integrated Dentistry Center, Faculty of Sarandi / Academy of Dentistry - Rio de Janeiro, at the CLIVO clinic, from among a total of 2.294 implants placed in the mandible, in the period from 1999 to 2007. There was a total of 1.056 short implants, of a length shorter than or equal to 10 mm, among which 20 implants were randomly chosen and analyzed. Results: The data were treated statistically and comparison of these data was consubstantiated in constructive data analysis by means of Statistical Pattern Recognition Methods for each variable under study. A success rate of 85% was obtained, and the need to take certain care when indicating the use of short implants was verified. Conclusion: Bioengineering and the development of present day surgical techniques have optimized the use of short implants, with the aim of avoiding advanced surgeries. To compensate the smaller size, there are some factors that must be observed, such as: Bone quality, crown/implant ratio, number and diameter of implants, macroscopic and microscopic geometry of the implants, magnitude of mesial occlusal forces.

  11. The Efficacy of Supportive Peri-Implant Therapies in Preventing Peri-Implantitis and Implant Loss: a Systematic Review of the Literature

    Directory of Open Access Journals (Sweden)

    Ausra Ramanauskaite

    2016-09-01

    Full Text Available Objectives: To study the efficacy of supportive peri-implant therapies in preventing clinical and radiological signs of peri-implantitis and implant loss. Material and Methods: Longitudinal human studies, published between January 1, 2006, and February 1, 2016, were included based on an electronic search using MEDLINE and EMBASE databases and complemented by a manual search. Articles were included only if 1 they comprised a group of patients involved in/adhering to regular supportive peri-implant therapies (SPTs and a control group without such therapies or with poor adherence to them, 2 the protocol of the SPTs was clearly described and 3 the outcome was indicated by means of clinical/radiological changes or implant loss. Results: After initially identifying a total of 710 titles and abstracts, 12 full text articles were selected for eligibility assessment. Seven studies, three prospective and four retrospective, fulfilled the inclusion criteria for this review. The frequency of recall visits varied between the studies from a minimum of one visit every three months to an individually tailored regimen. In all the studies a lack of SPTs or poor adherence to them resulted in significantly higher frequencies of sites with mucosal bleeding, deepened peri-implant pockets or alveolar bone loss. In line with the above, a lack of/poor adherence to SPTs was associated with higher implant loss. Conclusions: To prevent peri-implantitis, an individually tailored supportive programme based on patient motivation and re-instruction in oral hygiene measures combined with professional implant cleaning seem to be crucial.

  12. Towards a closed-loop cochlear implant system: application of embedded monitoring of peripheral and central neural activity.

    Science.gov (United States)

    Mc Laughlin, Myles; Lu, Thomas; Dimitrijevic, Andrew; Zeng, Fan-Gang

    2012-07-01

    Although the cochlear implant (CI) is widely considered the most successful neural prosthesis, it is essentially an open-loop system that requires extensive initial fitting and frequent tuning to maintain a high, but not necessarily optimal, level of performance. Two developments in neuroscience and neuroengineering now make it feasible to design a closed-loop CI. One development is the recording and interpretation of evoked potentials (EPs) from the peripheral to the central nervous system. The other is the embedded hardware and software of a modern CI that allows recording of EPs. We review EPs that are pertinent to behavioral functions from simple signal detection and loudness growth to speech discrimination and recognition. We also describe signal processing algorithms used for electric artifact reduction and cancellation, critical to the recording of electric EPs. We then present a conceptual design for a closed-loop CI that utilizes in an innovative way the embedded implant receiver and stimulators to record short latency compound action potentials ( ~1 ms), auditory brainstem responses (1-10 ms) and mid-to-late cortical potentials (20-300 ms). We compare EPs recorded using the CI to EPs obtained using standard scalp electrodes recording techniques. Future applications and capabilities are discussed in terms of the development of a new generation of closed-loop CIs and other neural prostheses.

  13. Implant-Abutment Contact Surfaces and Microgap Measurements of Different Implant Connections Under 3-Dimensional X-Ray Microtomography.

    Science.gov (United States)

    Scarano, Antonio; Valbonetti, Luca; Degidi, Marco; Pecci, Raffaella; Piattelli, Adriano; de Oliveira, P S; Perrotti, Vittoria

    2016-10-01

    The presence of a microgap between implant and abutment could produce a bacterial reservoir which could interfere with the long-term health of the periimplant tissues. The aim of this article was to evaluate, by x-ray 3-dimensional microtomography, implant-abutment contact surfaces and microgaps at the implant-abutment interface in different types of implant-abutment connections. A total of 40 implants were used in this in vitro study. Ten implants presented a screw-retained internal hexagon abutment (group I), 10 had a Morse Cone taper internal connection (group II), 10 another type of Morse Cone taper internal connection (group III), and 10 had a screwed trilobed connection (group IV). In both types of Morse Cone internal connections, there was no detectable separation at the implant-abutment in the area of the conical connection, and there was an absolute congruity without any microgaps between abutment and implant. No line was visible separating the implant and the abutment. On the contrary, in the screwed abutment implants, numerous gaps and voids were present. The results of this study support the hypothesis that different types of implant-abutment joints are responsible for the observed differences in bacterial penetration.

  14. Patient risk taking and spending habits correlate with willingness to pay for novel total joint arthroplasty implants

    Directory of Open Access Journals (Sweden)

    Ran Schwarzkopf, MD, MSc

    2015-03-01

    Full Text Available In this study, we compare patients' risk-taking and spending behaviors to their willingness to pay (WTP for novel implants in a joint arthroplasty. 210 patients were surveyed regarding risk-taking and spending behavior, and WTP for novel implants with either increased-longevity, increased-longevity with higher risk of complications, or decreased risk of complications compared to a standard implant. Patients with increased recreational risk-taking behavior were more WTP for increased-longevity. Patients who “rarely“ take health-risks were more WTP for decreased risk of complications. Patients with higher combined risk scores were more WTP for all novel implants. Patients who paid more than $50,000 for their current car were more WTP for decreased complications. This study shows that patients' risk taking and spending behavior influences their WTP for novel implants.

  15. Optimization of scan time in MRI for total hip prostheses. SEMAC tailoring for prosthetic implants containing different types of metals

    Energy Technology Data Exchange (ETDEWEB)

    Deligianni, X. [University of Basel Hospital, Basel (Switzerland). Div. of Radiological Physics; Merian Iselin Klinik, Basel (Switzerland). Inst. of Radiology; Bieri, O. [University of Basel Hospital, Basel (Switzerland). Div. of Radiological Physics; Elke, R. [Orthomerian, Basel (Switzerland); Wischer, T.; Egelhof, T. [Merian Iselin Klinik, Basel (Switzerland). Inst. of Radiology

    2015-12-15

    Magnetic resonance imaging (MRI) of soft tissues after total hip arthroplasty is of clinical interest for the diagnosis of various pathologies that are usually invisible with other imaging modalities. As a result, considerable effort has been put into the development of metal artifact reduction MRI strategies, such as slice encoding for metal artifact correction (SEMAC). Generally, the degree of metal artifact reduction with SEMAC directly relates to the overall time spent for acquisition, but there is no specific consensus about the most efficient sequence setup depending on the implant material. The aim of this article is to suggest material-tailored SEMAC protocol settings. Five of the most common total hip prostheses (1. Revision prosthesis (S-Rom), 2. Titanium alloy, 3. Mueller type (CoNiCRMo alloy), 4. Old Charnley prosthesis (Exeter/Stryker), 5. MS-30 stem (stainless-steel)) were scanned on a 1.5 T MRI clinical scanner with a SEMAC sequence with a range of artifact-resolving slice encoding steps (SES: 2 - 23) along the slice direction (yielding a total variable scan time ranging from 1 to 10 min). The reduction of the artifact volume in comparison with maximal artifact suppression was evaluated both quantitatively and qualitatively in order to establish a recommended number of steps for each case. The number of SES that reduced the artifact volume below approximately 300 mm{sup 3} ranged from 3 to 13, depending on the material. Our results showed that although 3 SES steps can be sufficient for artifact reduction for titanium prostheses, at least 11 SES should be used for prostheses made of materials such as certain alloys of stainless steel. Tailoring SES to the implant material and to the desired degree of metal artifact reduction represents a simple tool for workflow optimization of SEMAC imaging near total hip arthroplasty in a clinical setting.

  16. Optimization of scan time in MRI for total hip prostheses. SEMAC tailoring for prosthetic implants containing different types of metals

    International Nuclear Information System (INIS)

    Deligianni, X.; Wischer, T.; Egelhof, T.

    2015-01-01

    Magnetic resonance imaging (MRI) of soft tissues after total hip arthroplasty is of clinical interest for the diagnosis of various pathologies that are usually invisible with other imaging modalities. As a result, considerable effort has been put into the development of metal artifact reduction MRI strategies, such as slice encoding for metal artifact correction (SEMAC). Generally, the degree of metal artifact reduction with SEMAC directly relates to the overall time spent for acquisition, but there is no specific consensus about the most efficient sequence setup depending on the implant material. The aim of this article is to suggest material-tailored SEMAC protocol settings. Five of the most common total hip prostheses (1. Revision prosthesis (S-Rom), 2. Titanium alloy, 3. Mueller type (CoNiCRMo alloy), 4. Old Charnley prosthesis (Exeter/Stryker), 5. MS-30 stem (stainless-steel)) were scanned on a 1.5 T MRI clinical scanner with a SEMAC sequence with a range of artifact-resolving slice encoding steps (SES: 2 - 23) along the slice direction (yielding a total variable scan time ranging from 1 to 10 min). The reduction of the artifact volume in comparison with maximal artifact suppression was evaluated both quantitatively and qualitatively in order to establish a recommended number of steps for each case. The number of SES that reduced the artifact volume below approximately 300 mm 3 ranged from 3 to 13, depending on the material. Our results showed that although 3 SES steps can be sufficient for artifact reduction for titanium prostheses, at least 11 SES should be used for prostheses made of materials such as certain alloys of stainless steel. Tailoring SES to the implant material and to the desired degree of metal artifact reduction represents a simple tool for workflow optimization of SEMAC imaging near total hip arthroplasty in a clinical setting.

  17. Short-term and long-term outcome of radiological-guided insertion of central venous access port devices implanted at the forearm: a retrospective monocenter analysis in 1704 patients

    Energy Technology Data Exchange (ETDEWEB)

    Wildgruber, Moritz; Borgmeyer, Sebastian; Gaa, Jochen; Meier, Reinhard; Berger, Hermann [Technische Universitaet Muenchen, Division of Interventional Radiology, Department of Radiology, Klinikum Rechts der Isar, Muenchen (Germany); Haller, Bernhard [Technische Universitaet Muenchen, Department of Medical Statistics and Epidemiology, Klinikum Rechts der Isar, Munich (Germany); Jansen, Heike; Kiechle, Marion; Ettl, Johannes [Technische Universitaet Muenchen, Department of Obstetrics and Gynecology, Klinikum Rechts der Isar, Munich (Germany)

    2014-09-20

    The objectives are to analyze the technical success rate as well as the short-term and long-term complications of totally implantable venous access ports (TIVAPs) at the forearm. Retrospective analysis of 1,704 consecutively implanted TIVAPs was performed. Primary endpoints were defined as technical success rate, clinical outcome, device service interval, and rates of major complications. Minor complications not requiring port explantation were defined as secondary endpoints. The technical success rate was 99.2 % with no major complications. During follow-up, a total of 643,200 catheter-days were documented, the mean device service interval was 380.6 days/patient. A total of 243 complications (14.4 %) in 226 patients were observed (0.4/1000 catheter-days), in 140 patients (8.3 %) the port device had to be explanted. Disconnection between the port device and the catheter (1.6 %) was more frequent than fracture (0.8 %) and leakage (0.6 %) of the catheter, which occurred more frequently when the catheter was inserted via the cephalic versus the brachial vein. TIVAP implantation at the forearm is a simple and safe procedure with a low rate of early and late complications. (orig.)

  18. Evaluation of contiguous implants with cement-retained implant-abutment connections. A minipig study

    Directory of Open Access Journals (Sweden)

    Raquel Rezende Martins de Barros

    2014-03-01

    Full Text Available Aim: The presence of a microgap at the implant-abutment interface may permit bacterial contamination and lead to bone resorption, interfering with papillae formation. The present study evaluated adjacent implants with cement-retained abutments as an option to control such deleterious effects. Materials and methods Seven minipigs had their bilateral mandibular premolars previously extracted. After 8 weeks, four implants were installed in each hemi-mandible of each animal. The adjacent implants were randomly inserted on one side at the crestal bone level and on the other, 1.5 mm subcrestally. Immediately, a non-submerged healing and functional loading were provided with the abutments cementation and prostheses installation. Clinical examination and histomorphometry served to analyze the implant success. Results A total of 52 implants were evaluated at the end of the study. The subcrestal group achieved statistical better results when compared to the crestal group, clinically in papillae formation (1.97 x 1.57 mm and histomorphometrically in crestal bone remodeling (1.17 x 1.63 mm, bone density (52.39 x 45.22% and bone-implant contact (54.13 x 42.46%. Conclusion The subcrestal placement of cement-retained abutment implants showed better indexes of osseointegration and also improved papillae formation and crestal bone remodeling at the interimplant area after immediate loading, making them a promising option for the treatment of esthetic regions.

  19. Dental Implant Macro-Design Features Can Impact the Dynamics of Osseointegration.

    Science.gov (United States)

    Vivan Cardoso, Marcio; Vandamme, Katleen; Chaudhari, Amol; De Rycker, Judith; Van Meerbeek, Bart; Naert, Ignace; Duyck, Joke

    2015-08-01

    The purpose of this study was to compare the clinical performance of two dental implant types possessing a different macro-design in the in vivo pig model. Titanium Aadva(TM) implants (GC, Tokyo, Japan) were compared with OsseoSpeed(TM) implants (Astra, Mölndal, Sweden), with the Aadva implant displaying significant larger inter-thread dimensions than the OsseoSpeed implant. Implants were installed in the parietal bone of 12 domestic pigs and left for healing for either 1 or 3 months. Implant osseointegration was evaluated by quantitative histology (bone volume relative to the tissue volume [BV/TV]; bone-to-implant contact [BIC]) for distinct implant regions (collar, body, total implant length) with specific implant thread features. The Wilcoxon-Mann-Whitney nonparametric test with α = 0.05 was performed. An inferior amount of bone enveloping the Aadva implant compared with the OsseoSpeed implant was observed, in particular at the implant body part with its considerable inter-thread gaps (p macro-design negatively affected the amount of bone in direct contact with the implant for this specific implant part (p implant osseointegration at the initial healing stage (total implant length; 1-month healing; p implant displayed a clinically acceptable level of osseointegration, the findings demonstrate that implant macro-design features can impact the dynamics of implant osseointegration. Consideration of specific implant macro-design features should be made relative to the biological and mechanical microenvironment. © 2013 Wiley Periodicals, Inc.

  20. Microstructure and mechanical properties of open-cellular biomaterials prototypes for total knee replacement implants fabricated by electron beam melting.

    Science.gov (United States)

    Murr, L E; Amato, K N; Li, S J; Tian, Y X; Cheng, X Y; Gaytan, S M; Martinez, E; Shindo, P W; Medina, F; Wicker, R B

    2011-10-01

    Total knee replacement implants consisting of a Co-29Cr-6Mo alloy femoral component and a Ti-6Al-4V tibial component are the basis for the additive manufacturing of novel solid, mesh, and foam monoliths using electron beam melting (EBM). Ti-6Al-4V solid prototype microstructures were primarily α-phase acicular platelets while the mesh and foam structures were characterized by α(')-martensite with some residual α. The Co-29Cr-6Mo containing 0.22% C formed columnar (directional) Cr(23)C(6) carbides spaced ~2 μm in the build direction, while HIP-annealed Co-Cr alloy exhibited an intrinsic stacking fault microstructure. A log-log plot of relative stiffness versus relative density for Ti-6Al-4V and Co-29Cr-6Mo open-cellular mesh and foams resulted in a fitted line with a nearly ideal slope, n = 2.1. A stress shielding design graph constructed from these data permitted mesh and foam implant prototypes to be fabricated for compatible bone stiffness. Copyright © 2011 Elsevier Ltd. All rights reserved.

  1. Lipidic profile among rats submitted to total splenectomy isolated or combined with splenic autotransplant Perfil lipídico em ratos submetidos a esplenectomia total isolada ou combinada com auto-implante esplênico

    Directory of Open Access Journals (Sweden)

    Fernanda Correia Simões

    2007-01-01

    Full Text Available PURPOSE: To evaluate the alterations on plasmatic lipids levels among rats submitted to total splenectomy isolated or combined with splenic autotransplant receiving standard chow during the postoperative period. METHODS: Thirty Wistar rats were divided into three groups: control (C - sham-operated, total splenectomy - isolated (TS or combined with splenic autotransplantation (SA. Since the postoperative period, all animals received standard rat chow manipulated in accordance to the American Institute of Nutrition Rodents Diets (1993. The plasmatic levels of total cholesterol (TC, triglycerides (TG, high-density lipoprotein (HDL, low-density lipoprotein (LDL, very-low-density lipoprotein (VLDL, and glucose (GLUC were analyzed before the surgical procedure and after 6 and 12 weeks. RESULTS: All the animals presented significant increase of TG and VLDL levels. In relation to the other parameters there was no difference among the weeks 0 and 12 in the animals of group C. In TS group significant increase was observed in TC and GLUC levels during the experiment. In SA group TC, HDL, and GLUC levels remained unaffected while HDL levels increased. CONCLUSION: Our findings suggest that isolated total splenectomy alters lipids metabolism in rats fed with standard chow and splenic autotransplantation is effective in restoring its control.OBJETIVO: Avaliar as alterações nos níveis de lipídios plasmáticos em ratos submetidos a esplenectomia total isolada ou combinada com auto-implante esplênico, recebendo dieta padrão no período pós-operatório. MÉTODOS: Trinta ratos Wistar foram distribuídos em três grupos: controle (C - operação simulada, esplenectomia total isolada (ET ou combinada com auto-implante esplênico (AE. A partir do período pós-operatório, todos os animais receberam ração padrão, manipulada segundo o American Institute of Nutrition (1993. Os níveis plasmáticos de colesterol total (CT, triglicerídeos (TG, lipoproteína de

  2. [Technique of intraoperative planning in prostatic brachytherapy with permanent implants of 125I or 103Pd].

    Science.gov (United States)

    Prada Gómez, Pedro José; Juan Rijo, Germán; Hevia Suarez, Miguel; Abascal García, José María; Abascal García, Ramón

    2002-12-01

    Prostatic brachytherapy with permanent 125I or 123Pd seeds implantation is a therapeutic option for organ-confined prostate cancer. We analyze the technique based on previous planning, our current intraoperative planning procedure and the reasons that moved us to introduce this change. Changes in prostate volume and spatial localization observed between previous planning and intraoperative images, and possible difficulties for seed implantation due to pubic arch interference are some of the reasons that induce us to change technique. Before the operation, we calculate the prostatic volume by transrectal ultrasound; with this information we determine the total implant activity following Wu's nomogram, and per-seed activity; therefore, it is an individual process for each patient. We perform a peripheral implant, placing 75-80% of the seeds within the peripheral prostatic zone, generally through 12-15 needles, the rest of the seeds are placed in the central prostatic zone using a maximum of 3-4 needles in high volume prostates. The day of intervention, after positioning and catheter insertion, volumetry is re-checked. Ultrasound images (from base to apex every 5 mm) are transferred to the planner were a suitable seed distribution is determined. Implantation is then performed placing all needles unloaded, and then intraoperative post-planning to allow us to check implant precision is performed after cistoscopically check that there is no urethral or bladder penetration by any needle. We finish with the insertion of seeds into the prostate. Total time for the procedure is around 90 minutes. Intraoperative planning is an additional step for the treatment of prostate cancer with permanent seeds brachytherapy, which avoids the disadvantages of previous planning and improves tumor inclusion in the ideal irradiation dose area, which will translate into better local disease control.

  3. Ultrasound guided implantation of chest port systems via the lateral subclavian vein; Die sonographisch gezielte Implantation von Portkathetersystemen ueber die laterale Vena subclavia

    Energy Technology Data Exchange (ETDEWEB)

    Zaehringer, M.; Hilgers, J.; Krueger, K.; Strohe, D.; Bangard, C.; Neumann, L.; Lackner, K. [Inst. fuer Radiologische Diagnostik, Univ. zu Koeln (Germany); Warm, M. [Gynaekologie, Univ. zu Koeln (Germany); Reiser, M. [Medizinische Klinik I, Univ. zu Koeln (Germany); Toex, U. [Medizinische Klinik IV, Univ. zu Koeln (Germany)

    2006-03-15

    Purpose: Retrospective analysis of the success and complication rates of chest port implantation via the lateral subclavian vein. Materials and methods: Between January 2003 and June 2004, the lateral subclavian vein in 271 patients (186 women, 85 men, mean age 53.2 years) was punctured guided by ultrasound. This access was used to insert a port system, and the catheter tip was placed at the cavoatrial junction. The port reservoir was implanted in a subcutaneous infraclavicular pocket and fixed to the fascia of the pectoralis muscle. Indications for port implantation were chemotherapy (n=239), total parenteral nutrition (n=2) and intravenous medication (n=30). The patient follow-up was mainly performed either by the oncology division of the department of gynecology or by the department of internal medicine. Results: A chest port catheter system was successfully implanted in all patients. The catheter remained in place for a mean duration of 269.4 days (SD 192.3 days). No complications occurred during implantation. In the post-interventional period, 6 catheter dysfunctions were found (thrombotic 0.09 per 1000 catheter days; mechanic 0.05 per 1000 catheter days). While one local infection occurred in the early post-interventional period, 3 local and 15 systemic infections were independent of the port catheter placement (0.39 per 1000 catheter days). The rate of port catheter explantations due to dysfunction or infection was 0.07 per 1000 catheter days. Conclusion: Ultrasound-guided puncture of the lateral subclavian vein is a safe procedure for the insertion of central venous port catheter systems and had a very low complication rate in our study. For further evaluation of our port placement technique, prospective studies compared to placement through the internal jugular vein are necessary. (orig.)

  4. Central hemodynamic responses during serial exercise tests in heart failure patients using implantable hemodynamic monitors.

    Science.gov (United States)

    Ohlsson, A; Steinhaus, D; Kjellström, B; Ryden, L; Bennett, T

    2003-06-01

    Exercise testing is commonly used in patients with congestive heart failure for diagnostic and prognostic purposes. Such testing may be even more valuable if invasive hemodynamics are acquired. However, this will make the test more complex and expensive and only provides information from isolated moments. We studied serial exercise tests in heart failure patients with implanted hemodynamic monitors allowing recording of central hemodynamics. Twenty-one NYHA Class II-III heart failure patients underwent maximal exercise tests and submaximal bike or 6-min hall walk tests to quantify their hemodynamic responses and to study the feasibility of conducting exercise tests in patients with such devices. Patients were followed for 2-3 years with serial exercise tests. During maximal tests (n=70), heart rate increased by 52+/-19 bpm while S(v)O(2) decreased by 35+/-10% saturation units. RV systolic and diastolic pressure increased 29+/-11 and 11+/-6 mmHg, respectively, while pulmonary artery diastolic pressure increased 21+/-8 mmHg. Submaximal bike (n=196) and hall walk tests (n=172) resulted in S(v)O(2) changes of 80 and 91% of the maximal tests, while RV pressures ranged from 72 to 79% of maximal responses. An added potential value of implantable hemodynamic monitors in heart failure patients may be to quantitatively determine the true hemodynamic profile during standard non-invasive clinical exercise tests and to compare that to hemodynamic effects of regular exercise during daily living. It would be of interest to study whether such information could improve the ability to predict changes in a patient's clinical condition and to improve tailoring patient management.

  5. Implant Mandibular Overdentures Retained by Immediately Loaded Implants: A 1-Year Randomized Trial Comparing the Clinical and Radiographic Outcomes Between Mini Dental Implants and Standard-Sized Implants.

    Science.gov (United States)

    Zygogiannis, Kostas; Aartman, Irene Ha; Parsa, Azin; Tahmaseb, Ali; Wismeijer, Daniel

    The aim of this 1-year randomized trial was to evaluate and compare the clinical and radiographic performance of four immediately loaded mini dental implants (MDIs) and two immediately loaded standard-sized tissue-level (STL) implants, placed in the interforaminal region of the mandible and used to retain mandibular overdentures (IODs) in completely edentulous patients. A total of 50 completely edentulous patients wearing conventional maxillary dentures and complaining about insufficient retention of their mandibular dentures were divided into two groups; 25 patients received four MDIs and 25 patients received two STL implants. The marginal bone loss (MBL) at the mesial and distal sides of each implant was assessed by means of standardized intraoral radiographs after a period of 1 year. Implant success and survival rates were also calculated. Immediate loading was possible for all patients in the first group. In the second group, an immediate loading protocol could not be applied for 10 patients. These patients were treated with a delayed loading protocol. A mean MBL of 0.42 ± 0.56 mm for the MDIs and 0.54 ± 0.49 mm for the immediately loaded STL implants was recorded at the end of the evaluation period. There was no statistically significant difference between the MDIs and the immediately loaded STL implants. Two MDIs failed, resulting in a survival rate of 98%. The success rate was 91%. For the immediately loaded conventional implants, the survival rate was 100% and the success rate 96.7% after 1 year of function. However, in 10 patients, the immediate loading protocol could not be followed. Considering the limitations of this short-term clinical study, immediate loading of four unsplinted MDIs or two splinted STL implants to retain mandibular overdentures seems to be a feasible treatment option. The marginal bone level changes around the MDIs were well within the clinically acceptable range.

  6. Failure rate of cemented and uncemented total hip replacements

    DEFF Research Database (Denmark)

    Makela, K. T.; Matilainen, M.; Pulkkinen, P.

    2014-01-01

    ). Participants 347 899 total hip replacements performed during 1995-2011. Main outcome measures Probability of implant survival (Kaplan-Meier analysis) along with implant survival with revision for any reason as endpoint (Cox multiple regression) adjusted for age, sex, and diagnosis in age groups 55-64, 65......Objective To assess the failure rate of cemented, uncemented, hybrid, and reverse hybrid total hip replacements in patients aged 55 years or older. Design Register study. Setting Nordic Arthroplasty Register Association database (combined data from Sweden, Norway, Denmark, and Finland......-74, and 75 years or older. Results The proportion of total hip replacements using uncemented implants increased rapidly towards the end of the study period. The 10 year survival of cemented implants in patients aged 65 to 74 and 75 or older (93.8%, 95% confidence interval 93.6% to 94.0% and 95.9%, 95...

  7. Working memory in Farsi-speaking children with normal development and cochlear implant.

    Science.gov (United States)

    Soleymani, Zahra; Amidfar, Meysam; Dadgar, Hooshang; Jalaie, Shohre

    2014-04-01

    Working memory has an important role in language acquisition and development of cognition skills. The ability of encoding, storage and retrieval of phonological codes, as activities of working memory, acquired by audition sense. Children with cochlear implant experience a period that they are not able to perceive sounds. In order to assess the effect of hearing on working memory, we investigated working memory as a cognition skill in children with normal development and cochlear implant. Fifty students with normal hearing and 50 students with cochlear implant aged 5-7 years participated in this study. Children educated in the preschool, the first and second grades. Children with normal development were matched based on age, gender, and grade of education with cochlear implant. Two components of working memory including phonological loop and central executive were compared between two groups. Phonological loop assessed by nonword repetition task and forward digit span. To assess central executive component backward digit span was used. The developmental trend was studied in children with normal development and cochlear implant as well. The effect of age at implantation in children with cochlear implants on components of working memory was investigated. There are significant differences between children with normal development and cochlear implant in all tasks that assess working memory (p memory between different grades showed significant differences both in children with normal development and in children with cochlear implant (p implied that children with cochlear implant may experience difficulties in working memory. Therefore, these children have problems in encoding, practicing, and repeating phonological units. The results also suggested working memory develops when the child grows up. In cochlear implant children, with decreasing age at implantation and increasing their experience in perceiving sound, working memory skills improved. Copyright © 2014 Elsevier

  8. Influences of microgap and micromotion of implant-abutment interface on marginal bone loss around implant neck.

    Science.gov (United States)

    Liu, Yang; Wang, Jiawei

    2017-11-01

    To review the influences and clinical implications of micro-gap and micro-motion of implant-abutment interface on marginal bone loss around the neck of implant. Literatures were searched based on the following Keywords: implant-abutment interface/implant-abutment connection/implant-abutment conjunction, microgap, micromotion/micromovement, microleakage, and current control methods available. The papers were then screened through titles, abstracts, and full texts. A total of 83 studies were included in the literature review. Two-piece implant systems are widely used in clinics. However, the production error and masticatory load result in the presence of microgap and micromotion between the implant and the abutment, which directly or indirectly causes microleakage and mechanical damage. Consequently, the degrees of microgap and micromotion further increase, and marginal bone absorption finally occurs. We summarize the influences of microgap and micromotion at the implant-abutment interface on marginal bone loss around the neck of the implant. We also recommend some feasible methods to reduce their effect. Clinicians and patients should pay more attention to the mechanisms as well as the control methods of microgap and micromotion. To reduce the corresponding detriment to the implant marginal bone, suitable Morse taper or hybrid connection implants and platform switching abutments should be selected, as well as other potential methods. Copyright © 2017 Elsevier Ltd. All rights reserved.

  9. The biocompatibility of SLA-treated titanium implants

    International Nuclear Information System (INIS)

    Kim, Hyeongil; Choi, Seong-Ho; Ryu, Jae-Jun; Koh, Seung-Yong; Park, Ju-Han; Lee, In-Seop

    2008-01-01

    The titanium implant surface was sandblasted with large grits and acid etched (SLA) to increase the implant surface for osseointegration. The topography of the titanium surface was investigated with scanning electron microscopy (SEM) and a profilometer. The SLA implant demonstrated uniform small micro pits (1-2 μm in diameter). The values of average roughness (R a ) and maximum height (R t ) were 1.19 μm and 10.53 μm respectively after sandblasting and the acid-etching treatment. In the cell-surface interaction study, the human osteoblast cells grew well in vitro. The in vivo evaluation of the SLA implant placed in rabbit tibia showed good bone-to-implant contact (BIC) with a mean value of 29% in total length of the implant. In the short-term clinical study, SLA implants demonstrated good clinical performance, maintaining good crestal bone height

  10. Load Transfer Characteristics of Various Designs of Three-Implant-Retained Mandibular Overdentures.

    Science.gov (United States)

    Tokar, Emre; Uludag, Bulent

    2015-01-01

    Many different attachment systems (eg, bars, studs, magnets, telescopic copings) have been used to retain overdentures. The current study aimed to investigate the load transfer characteristics and to compare the stress levels of four attachment designs for mandibular overdentures retained by one central implant and two inclined distal implants. Photoelastic mandibular models fabricated with three screw-type implants (Tapered Screw-Vent, 3.75 × 13 mm) were placed in the parasymphyseal area. The center implant was vertically oriented to the midline, and the other implants were embedded in the canine areas with a 20-degree angulation relative to the center implant. Four overdentures with different attachment designs (bar, bar/ball, bar/distally placed Rk-1s, and Locators) were studied in the context of this model. Vertical loads (100 N) were applied to the central fossa of the right first molar area of each overdenture. Stress levels that developed in the denture-bearing areas and around the implants were observed photoelastically and evaluated visually. The studied attachment designs showed low and moderate stress levels. The greatest stress was found with the bar/ball design, while the lowest stress levels were observed with the Locator attachment design. Stresses were concentrated on the loaded side for each design. All tested designs experienced moderate stress around the posterior edentulous area. None of the designs experienced more than moderate stress. The lowest stress was noted with the Locator attachments, which transmitted little discernible stress around the implants.

  11. Implants for orthodontic anchorage

    Science.gov (United States)

    Zheng, Xiaowen; Sun, Yannan; Zhang, Yimei; Cai, Ting; Sun, Feng; Lin, Jiuxiang

    2018-01-01

    Abstract Implantanchorage continues to receive much attention as an important orthodontic anchorage. Since the development of orthodontic implants, the scope of applications has continued to increase. Although multiple reviews detailing implants have been published, no comprehensive evaluations have been performed. Thus, the purpose of this study was to comprehensively evaluate the effects of implants based on data published in review articles. An electronic search of the Cochrane Library, Medline, Embase, Ebsco and Sicencedirect for reviews with “orthodontic” and “systematic review or meta analysis” in the title, abstract, keywords, or full text was performed. A subsequent manual search was then performed to identify reviews concerning orthodontic implants. A manual search of the orthodontic journals American Journal of Orthodontics and Dentofacial Orthopedics (AJODO), European Journal of Orthodontics (EJO), and Angle Othodontist was also performed. Such systematic reviews that evaluated the efficacy and safety of orthodontic implants were used to indicate success rates and molar movements. A total of 23 reviews were included in the analysis. The quality of each review was assessed using a measurement tool for Assessment of Multiple Systematic Reviews (AMSTAR), and the review chosen to summarize outcomes had a quality score of >6. Most reviews were less than moderate quality. Success rates of implants ranged in a broad scope, and movement of the maxillary first molar was superior with implants compared with traditional anchorage. PMID:29595673

  12. Role of clinician's experience and implant design on implant stability. An ex vivo study in artificial soft bones.

    Science.gov (United States)

    Romanos, Georgios E; Basha-Hijazi, Abdulaziz; Gupta, Bhumija; Ren, Yan-Fang; Malmstrom, Hans

    2014-04-01

    Clinical experience in implant placement is important in order to prevent implant failures. However, the implant design affects the primary implant stability (PS) especially in poor quality bones. Therefore, the aim of this study was to compare the effect of clinician surgical experience on PS, when placing different type of implant designs. A total of 180 implants (90 parallel walled-P and 90 tapered-T) were placed in freshly slaughtered cow ribs. Bone quality was evaluated by two examiners during surgery and considered as 'type IV' bone. Implants (ø 5 mm, length: 15 mm, Osseotite, BIOMET 3i, Palm Beach Gardens, FL, USA) were placed by three different clinicians (master/I, good/II, non-experienced/III, under direct supervision of a manufacturer representative; 30 implants/group). An independent observer assessed the accuracy of placement by resonance frequency analysis (RFA) with implant stability quotient (ISQ) values. Two-way analysis of variance (ANOVA) and Tukey's post hoc test were used to detect the surgical experience of the clinicians and their interaction and effects of implant design on the PS. All implants were mechanically stable. The mean ISQ values were: 49.57(± 18.49) for the P-implants and 67.07(± 8.79) for the T-implants. The two-way ANOVA showed significant effects of implant design (p bone. © 2012 Wiley Periodicals, Inc.

  13. Does antibiotic prophylaxis at implant placement decrease early implant failures? A Cochrane systematic review.

    Science.gov (United States)

    Esposito, Marco; Grusovin, Maria Gabriella; Loli, Vasiliki; Coulthard, Paul; Worthington, Helen V

    2010-01-01

    Marco Esposito is the first author of two of the included studies; however, he was not involved in the quality assessment of these trials. This review is based on a Cochrane systematic review entitled 'Interventions for replacing missing teeth: antibiotics at dental implant placement to prevent complications' published in The Cochrane Library (see http://www.cochrane.org for more information). Cochrane systematic reviews are regularly updated to include new research, and in response to comments and criticisms from readers. If you wish to comment on this review, please send your comments to the Cochrane website or to Marco Esposito. The Cochrane Library should be consulted for the most recent version of the review. The results of a Cochrane Review can be interpreted differently, depending on people's perspectives and circumstances. Please consider the conclusions presented carefully. They are the opinions of the review authors, and are not necessarily shared by the Cochrane Collaboration. To assess the beneficial or harmful effects of systemic prophylactic antibiotics at dental implant placement versus no antibiotic/placebo administration and, if antibiotics are of benefit, to find which type, dosage and duration is the most effective. The Cochrane Oral Health Group's Trials Register, the Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE and EMBASE were searched up to 2 June 2010 for randomised controlled clinical trials (RCTs) with a follow-up of at least 3 months comparing the administration of various prophylactic antibiotic regimens versus no antibiotics to patients undergoing dental implant placement. Outcome measures were prosthesis failures, implant failures, postoperative infections and adverse events (gastrointestinal, hypersensitivity, etc.). Screening of eligible studies, assessment of the methodological quality of the trials and data extraction were conducted in duplicate and independently by two review authors. Meta-analyses were

  14. Nasopalatine duct cyst associated with dental implant treatment: A case report

    Directory of Open Access Journals (Sweden)

    Shintaro Sukegawa, DDS, PhD

    2015-09-01

    Full Text Available Maxillary anterior implants are associated with the risk of nasopalatine canal damage. Here we present the case of a 37-year-old man who developed a nasopalatine duct cyst after maxillary implant placement. The patient received an implant 3 months after the extraction of a fractured maxillary right central incisor. At a maintenance visit 9 years after the procedure, he complained of swelling and mild pain in the palatal region of the implant. A panoramic radiograph and computed tomography (CT scan revealed a large, well-circumscribed, periapical radiolucency surrounding the apical portion of the implant and extending to the nasopalatine duct. We removed the entire lesion without removing the implant. Histopathologic examination of the resected specimen revealed a nasopalatine duct cyst. Accidental contact with the nasopalatine canal during implant surgery may have led to the development of the nasopalatine duct cyst. Careful planning using a preoperative CT scan prior to implant placement may prevent such complications.

  15. Influence of central panoramic curve deviation of the mandibular image reconstruction in the implant CT

    International Nuclear Information System (INIS)

    Park, Rae Jeong; Lee, Sam Sun; Choi, Soon Chul; Park, Tae Won; You, Dong Soo

    1998-01-01

    The purpose of this study was to investigate an influence of the change of central panoramic curves on the image reconstruction in the dental implant CT. The author designed three experimental groups according to the location of central panoramic curve. In group A, central panoramic curve was determined as the curve connecting the center of roots from the first premolar to the first molar. In group B, central panoramic curve was determined as the line connecting the lingual cortical plate at the level of the mesial aspect of the first premolar with the buccal cortical plate at the level of the mesial aspect of the first molar. In group C, central panoramic curve was determined as the line connecting the buccal cortical plate at the level of the mesial aspect of the first molar. Twenty four reformatted CT images was acquired from four mandibles embedded in the resin block and twenty four contact radiographs of dog specimens were acquired. Each image was processed under Adobe Photoshop program analysed by MSPA (mandible/maxilla shape pattern analysis) variables such as MXVD, MXHD, UHD, MHD, and LHD. The obtained results were as follows ; 1. The mean of MXVD variable was 19.9, 20.2, and 20.0 in group A, B, and C, respectively, which were smaller than actual value 20.5. But, there was no significant difference among 3 groups (p>0.05). 2. The mean of MXHD, UHD, MHD, and LHD variables in group A, B, and C was 11.9, 12.2, and 12.3; 9.3, 9.5, and 9.6; 10.0, 10.3,and 10.3; 9.2, 9.3, and 9.4 respectively which were equal to or greater than the actual value 11.8, 9.3, 10.0. But, there was no significant difference among 3 groups (p>0.05). 3. The number of noneffective observations with difference over or under 1 mm with comparison to the actual value was 24 (20%), 58 (48.3%), and 52 (43.3%), respectively, in group A, B, and C. 4. In group A, the number of observations over 1mm and under 1 mm was 9 and 15, respectively, but in group B and C, the number of observations over 1

  16. Effect of insertion torque on titanium implant osseointegration: an animal experimental study.

    Science.gov (United States)

    Duyck, Joke; Roesems, Rutger; Cardoso, Marcio V; Ogawa, Toru; De Villa Camargos, Germana; Vandamme, Katleen

    2015-02-01

    To evaluate the effect of implant insertion torque on the peri-implant bone healing and implant osseointegration. Bilaterally in the tibia of five adult New Zealand white rabbits, 20 implants were installed, subdivided into four groups, corresponding to two insertion torque conditions (low, 50 Ncm) and 2 experimental periods (2 weeks vs. 4 weeks of healing). The implant insertion torque was determined by the surgical drill diameter relative to the implant diameter. Implant osseointegration was evaluated by quantitative histology (bone-to-implant contact with host bone [BIC-host], with neoformed bone [BIC-de novo], with both bone types [BIC-total], and peri-implant bone [BA/TA]). Every response was modelled over time using GEE (general estimation equation) with an unstructured variance-covariance matrix to correct for dependency between the measurements from one animal. The statistical significance level of α = 0.05 was applied. Significantly, more BIC-host and BIC-total were recorded for H implants compared with L implants after 2 week of healing (P = 0.010 and P = 0.0001, respectively). However, this result was no longer found for the extended healing period. Furthermore, BIC-total significantly increased over time for L implants (P torque led to an increased BA/TA after 4 week of healing (P torque implants installed in the rabbit tibial bone osseointegrate with considerable de novo bone formation. This bone neoformation enables L implants to catch up, already during the early osseointegration stage, the initial inferior amount BIC contact compared with that of H implants. A negative impact of the created strain environment accompanying H insertion torque implant installation on the biological process of osseointegration could not be observed, at least not at tissue level. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  17. Central venous access through the external jugular vein in children submitted to bone marrow transplantation

    Directory of Open Access Journals (Sweden)

    José Luiz de Godoy

    2005-01-01

    Full Text Available Establishment of long-term central venous access is a sine qua non step for bone marrow transplantation in children. Most frequently, long-term central venous access has been obtained via blind percutaneous cannulation of subclavian and internal jugular veins or via internal jugular vein cutdown. In order to avoid some potential minor and major complications associated with the subclavian or internal jugular approaches, the authors describe an easy, simple and safe method for central venous access through an external jugular vein cutdown that should be of interest to readers involved in the field of bone marrow transplantation. It should be also considered for children as well as adults needing central venous access via an external catheter - or totally implantable port - for reasons other than bone marrow transplantation, such as total parenteral nutrition and administration of chemotherapeutic agents.O estabelecimento de um acesso venoso central de longa duração é uma condição sine qua non para realizar o transplante de medula óssea em crianças. Com frequência, este acesso tem sido obtido através da punção percutânea das veias subclávia e jugular interna ou via dissecção da jugular interna. Com o objetivo de evitar algumas complicações maiores e menores associadas com a subclávia e a jugular interna, os autores descrevem um método simples, fácil e seguro para o acesso venoso central através de dissecção da veia jugular externa. Este método deveria ser de interesse dos leitores envolvidos com o transplante de medula óssea e ser considerado também para crianças e/ou adultos que necessitem de cateter venoso central de longa permanência (externo ou totalmente implantável devido a outras razões, como a nutrição parenteral ou a administração de agentes quimioterápicos.

  18. Aseptic loosening of the femoral implant after cemented total hip arthroplasty in dogs: 11 cases in 10 dogs (1991-1995)

    International Nuclear Information System (INIS)

    Edwards, M.R.; Egger, E.L.; Schwarz, P.D.

    1997-01-01

    Objective-To determine clinical signs, radiographic findings, results of surgical management, and potential causes of aseptic loosening of the femoral implant (ALFI) in dogs that have undergone cemented total hip arthroplasty (THA). Design-Retrospective study. Animals-11 cases of ALFI in 10 dogs. Procedure-Medical records of all dogs undergoing THA revision surgery were reviewed. Only dogs with ALFI were included. The prosthesis and cement were removed by creating a longitudinal osteotomy of the cranial femoral cortex. Postoperative radiographs of all dogs that underwent THA during the study period were reviewed. Results-The most common clinical sign was intermittent, subtle. or non-weight-bearing lameness. On radiographs obtained after THA, contact of the distal stem tip with cortical endosteum was evident in all dogs. Radiographic changes at the time of diagnosis of ALFI included asymmetric periosteal reaction along the femoral diaphysis, radiolucent lines between the prosthesis and cement, altered implant position, and femoral fracture. Surgical revision yielded good or excellent results in 9 cases. In 1 dog. the implant became infected; in another, aseptic loosening recurred. Aseptic loosening was significantly more common in dogs in which there was contact between the distal stem tip and cortical endosteum than in dogs in which there was no contact. Clinical Implications-ALFI is an uncommon, but important, complication of THA, and radiography is warranted in dogs with clinical signs of ALFI. Initial centering of the prosthetic stem within the femoral shaft may reduce the incidence of ALFI

  19. Central Venous Catheter-Related Bloodstream Infection with Kocuria kristinae in a Patient with Propionic Acidemia

    OpenAIRE

    Kimura, Masato; Kawai, Eichiro; Yaoita, Hisao; Ichinoi, Natsuko; Sakamoto, Osamu; Kure, Shigeo

    2017-01-01

    Kocuria kristinae is a catalase-positive, coagulase-negative, Gram-positive coccus found in the environment and in normal skin and mucosa in humans; however, it is rarely isolated from clinical specimens and is considered a nonpathogenic bacterium. We describe a case of catheter-related bacteremia due to K. kristinae in a young adult with propionic acidemia undergoing periodic hemodialysis. The patient had a central venous catheter implanted for total parenteral nutrition approximately 6 mont...

  20. Revision Total Hip Arthoplasty: Factors Associated with Re-Revision Surgery

    OpenAIRE

    Khatod, M; Cafri, G; Inacio, MCS; Schepps, AL; Paxton, EW; Bini, SA

    2015-01-01

    The survivorship of implants after revision total hip arthroplasty and risk factors associated with re-revision are not well defined. We evaluated the re-revision rate with use of the institutional total joint replacement registry. The purpose of this study was to determine patient, implant, and surgeon factors associated with re-revision total hip arthroplasty.A retrospective cohort study was conducted. The total joint replacement registry was used to identify patients who had undergone revi...

  1. Wireless Power Transfer Strategies for Implantable Bioelectronics.

    Science.gov (United States)

    Agarwal, Kush; Jegadeesan, Rangarajan; Guo, Yong-Xin; Thakor, Nitish V

    2017-01-01

    Neural implants have emerged over the last decade as highly effective solutions for the treatment of dysfunctions and disorders of the nervous system. These implants establish a direct, often bidirectional, interface to the nervous system, both sensing neural signals and providing therapeutic treatments. As a result of the technological progress and successful clinical demonstrations, completely implantable solutions have become a reality and are now commercially available for the treatment of various functional disorders. Central to this development is the wireless power transfer (WPT) that has enabled implantable medical devices (IMDs) to function for extended durations in mobile subjects. In this review, we present the theory, link design, and challenges, along with their probable solutions for the traditional near-field resonant inductively coupled WPT, capacitively coupled short-ranged WPT, and more recently developed ultrasonic, mid-field, and far-field coupled WPT technologies for implantable applications. A comparison of various power transfer methods based on their power budgets and WPT range follows. Power requirements of specific implants like cochlear, retinal, cortical, and peripheral are also considered and currently available IMD solutions are discussed. Patient's safety concerns with respect to electrical, biological, physical, electromagnetic interference, and cyber security from an implanted neurotech device are also explored in this review. Finally, we discuss and anticipate future developments that will enhance the capabilities of current-day wirelessly powered implants and make them more efficient and integrable with other electronic components in IMDs.

  2. The pharmacokinetics and safety of an intraoperative bupivacaine-collagen implant (XaraColl® for postoperative analgesia in women following total abdominal hysterectomy

    Directory of Open Access Journals (Sweden)

    Cusack SL

    2013-03-01

    Full Text Available Susan L Cusack,1 Philip Reginald,2 Lisa Hemsen,3 Emmanuel Umerah21Cusack Pharmaceutical Consulting, Burlington, NJ, USA; 2Departments of Gynaecology and Anaesthetics, Wexham Park Hospital, Slough, SL2 4HL, UK; 3Innocoll Technologies, Athlone, IrelandBackground: XaraColl®, a collagen-based intraoperative implant that delivers bupivacaine to the site of surgical trauma, is under development for postoperative analgesia. We examined the pharmacokinetics, safety and efficacy of XaraColl following implantation in women undergoing total abdominal hysterectomy.Methods: Three XaraColl implants, each containing 50 mg bupivacaine hydrochloride, were implanted in 12 women undergoing total abdominal hysterectomy for a benign condition. Serum samples were obtained through 96 hours for pharmacokinetic analysis. Patients received acetaminophen 1000 mg every 6 hours, diclofenac 50 mg every 8 hours, and were given access to intravenous morphine for breakthrough pain via patient-controlled analgesia during the first 24 hours. Pain intensity was assessed at regular intervals using a 100 mm visual analog scale. Safety was assessed through 30 days.Results: The pharmacokinetic profile displayed a double peak in bupivacaine concentration with the second peak occurring up to 24 hours after the first and at a generally higher concentration. The time to maximum concentration (tmax varied from 0.5 to 24 hours (median 12 hours according to which peak predominated. The mean maximum concentration (Cmax was 0.22 µg/mL and the maximum individual Cmax was 0.44 µg/mL, which are well below the established systemic toxicity threshold. Morphine use was generally low (mean 16.8 mg; median 6.5 mg and compared favorably with institutional experience. At 6 hours post-surgery, 11 patients recorded pain scores ≤ 20 mm, 6 recorded ≤ 10 mm, and 2 reported no pain. Scores continued to decline throughout the study. The product was considered safe and well tolerated.Conclusion: Xara

  3. Localization and Tracking of Implantable Biomedical Sensors

    Directory of Open Access Journals (Sweden)

    Ilknur Umay

    2017-03-01

    Full Text Available Implantable sensor systems are effective tools for biomedical diagnosis, visualization and treatment of various health conditions, attracting the interest of researchers, as well as healthcare practitioners. These systems efficiently and conveniently provide essential data of the body part being diagnosed, such as gastrointestinal (temperature, pH, pressure parameter values, blood glucose and pressure levels and electrocardiogram data. Such data are first transmitted from the implantable sensor units to an external receiver node or network and then to a central monitoring and control (computer unit for analysis, diagnosis and/or treatment. Implantable sensor units are typically in the form of mobile microrobotic capsules or implanted stationary (body-fixed units. In particular, capsule-based systems have attracted significant research interest recently, with a variety of applications, including endoscopy, microsurgery, drug delivery and biopsy. In such implantable sensor systems, one of the most challenging problems is the accurate localization and tracking of the microrobotic sensor unit (e.g., robotic capsule inside the human body. This article presents a literature review of the existing localization and tracking techniques for robotic implantable sensor systems with their merits and limitations and possible solutions of the proposed localization methods. The article also provides a brief discussion on the connection and cooperation of such techniques with wearable biomedical sensor systems.

  4. Evaluation of stabilization techniques for ion implant processing

    Science.gov (United States)

    Ross, Matthew F.; Wong, Selmer S.; Minter, Jason P.; Marlowe, Trey; Narcy, Mark E.; Livesay, William R.

    1999-06-01

    With the integration of high current ion implant processing into volume CMOS manufacturing, the need for photoresist stabilization to achieve a stable ion implant process is critical. This study compares electron beam stabilization, a non-thermal process, with more traditional thermal stabilization techniques such as hot plate baking and vacuum oven processing. The electron beam processing is carried out in a flood exposure system with no active heating of the wafer. These stabilization techniques are applied to typical ion implant processes that might be found in a CMOS production process flow. The stabilization processes are applied to a 1.1 micrometers thick PFI-38A i-line photoresist film prior to ion implant processing. Post stabilization CD variation is detailed with respect to wall slope and feature integrity. SEM photographs detail the effects of the stabilization technique on photoresist features. The thermal stability of the photoresist is shown for different levels of stabilization and post stabilization thermal cycling. Thermal flow stability of the photoresist is detailed via SEM photographs. A significant improvement in thermal stability is achieved with the electron beam process, such that photoresist features are stable to temperatures in excess of 200 degrees C. Ion implant processing parameters are evaluated and compared for the different stabilization methods. Ion implant system end-station chamber pressure is detailed as a function of ion implant process and stabilization condition. The ion implant process conditions are detailed for varying factors such as ion current, energy, and total dose. A reduction in the ion implant systems end-station chamber pressure is achieved with the electron beam stabilization process over the other techniques considered. This reduction in end-station chamber pressure is shown to provide a reduction in total process time for a given ion implant dose. Improvements in the ion implant process are detailed across

  5. The vestibular implant: Quo vadis?

    Directory of Open Access Journals (Sweden)

    Raymond eVan De Berg

    2011-08-01

    Full Text Available AbstractObjective: to assess the progress of the development of the vestibular implant and its feasibility short-term. Data sources: a search was performed in Pubmed, Medline and Embase. Key words used were vestibular prosth* and vestibular implant. The only search limit was language: English or Dutch. Additional sources were medical books, conference lectures and our personal experience with per-operative vestibular stimulation in patients selected for cochlear implantation.Study selection: all studies about the vestibular implant and related topics were included and evaluated by two reviewers. No study was excluded since every study investigated different aspects of the vestibular implant. Data extraction and synthesis: data was extracted by the first author from selected reports, supplemented by additional information, medical books conference lectures. Since each study had its own point of interest with its own outcomes, it was not possible to compare data of different studies. Conclusion: to use a basic vestibular implant in humans seems feasible in the very near future. Investigations show that electric stimulation of the canal nerves induces a nystagmus which corresponds to the plane of the canal which is innervated by the stimulated nerve branch. The brain is able to adapt to a higher baseline stimulation, while still reacting on a dynamic component. The best response will be achieved by a combination of the optimal stimulus (stimulus profile, stimulus location, precompensation, complemented by central vestibular adaptation. The degree of response will probably vary between individuals, depending on pathology and their ability to adapt.

  6. Implant R100 Predicts Rectal Bleeding in Prostate Cancer Patients Treated with IG-IMRT to 45 Gy and Pd-103 Implant

    International Nuclear Information System (INIS)

    Packard, M.; Fuhrer, R.; Valakh, V.

    2014-01-01

    Purpose. To define factors associated with rectal bleeding in patients treated with IG-IMRT followed by Pd-103 seed implant. Methods and Materials. We retrospectively reviewed 61 prostate adenocarcinoma patients from 2002 to 2008. The majority (85.2%) were of NCCN intermediate risk category. All received IG-IMRT to the prostate and seminal vesicles followed by Pd-103 implant delivering a mean D90 of 100.7 Gy. Six patients received 45 Gy to the pelvic nodes and 10 received androgen deprivation. Results. Ten patients (16.4%) developed rectal bleeding: 4 were CTCAE v.3 grade 1, 5 were grade 2, and 1 was grade 3. By univariate analysis, age, stage, Gleason sum, PSA, hormonal therapy, pelvic radiation, postoperative prostate volume, D9, V100, individual source activity, total implanted activity per cm 3 , and duration of interval before implant did not impact rectal bleeding. Implant R100 was higher in patients with rectal bleeding: on average, 0.885 versus 0.396 cm 3 ,(Ρ =0.02) , odds ratio of 2.26 per .5 cm 3 (95% CI, 1.16–4.82). A trend for significance was seen for prostate V200 and total implanted activity. Conclusion. Higher implant R100 was associated with development of rectal bleeding in patients receiving IG-IMRT to 45 Gy followed by Pd-103 implant. Minimizing implant R100 may reduce the rate of rectal bleeding in similar patients.

  7. Settling of abutments into implants and changes in removal torque in five different implant-abutment connections. Part 1: Cyclic loading.

    Science.gov (United States)

    Kim, Ki-Seong; Han, Jung-Suk; Lim, Young-Jun

    2014-01-01

    The aim of this study was to evaluate and compare the settling of abutments into implants and the removal torque values (RTVs) before and after cyclic loading. Five different implant-abutment connections were tested: Ext = external butt joint + two-piece abutment; Int-H2 = internal hexagon + two-piece abutment; Int-H1 = internal hexagon + one-piece abutment; Int-O2 = internal octagon + two-piece abutment; and Int-O1 = internal octagon + one-piece abutment. Ten abutments from each group were secured to their corresponding implants (total n = 50). All samples were tested in a universal testing machine with a vertical load of 250 N for 100,000 cycles of 14 Hz. The amount of settling of the abutment into the implant was calculated from the change in the total length of the implant-abutment sample before and after loading, as measured with an electronic digital micrometer. The RTV after cyclic loading was compared to the initial RTV with a digital torque gauge. Statistical analysis was performed at a 5% significance level. A multiple-comparison test showed specific significant differences in settling values in each group after 250 N cyclic loading (Int-H1, Ext abutment type and related to the design characteristics of the implant-abutment connection.

  8. Systemic Assessment of Patients Undergoing Dental Implant ...

    African Journals Online (AJOL)

    Background: Procedure‑related and patient‑related factors influence the prognosis of dental implants to a major extent. Hence, we aimed to evaluate and analyze various systemic factors in patients receiving dental implants. Materials and Methods: Fifty‑one patients were included in the study, in which a total of 110 dental ...

  9. Implantable and transdermal polymeric drug delivery technologies for the treatment of central nervous system disorders.

    Science.gov (United States)

    Govender, Thiresen; Choonara, Yahya E; Kumar, Pradeep; Bijukumar, Divya; du Toit, Lisa C; Modi, Girish; Naidoo, Dinesh; Pillay, Viness

    2017-06-01

    The complexity of the brain and the membranous blood-brain barrier (BBB) has proved to be a significant limitation to the systemic delivery of pharmaceuticals to the brain rendering them sub-therapeutic and ineffective in the treatment of neurological diseases. Apart from this, lack of innovation in product development to counteract the problem is also a major contributing factor to a poor therapeutic outcome. Various innovative strategies show potential in treating some of the neurological disorders; however, drug delivery remains the most popular. To attain therapeutic drug levels in the central nervous system, large, intolerable systemic doses are generally administered. The major factors responsible for the success maintenance therapy of neurological diseases included controlled and sustained release of neurotherapeutics, reduced frequency of administration, higher bioavailability, and patient compliances. Conventional oral or injectable formulations cannot satisfy all the requirements in many circumstances. This article reviews the therapeutic implantable polymeric and transdermal devices employed in an attempt to effectively achieve therapeutic quantities of drug across the BBB over a prolonged period, to improve patient disease prognosis.

  10. Comparative evaluation of peri-implant tissues in patients wearing mandibular overdenture with different implant platforms

    Directory of Open Access Journals (Sweden)

    Laércio Almeida de Melo

    2017-01-01

    Full Text Available Background: The poor hygiene of peri-implant tissues causes inflammation at tissue-implant interface, which may impair the rehabilitation success. The aim of this study was to evaluate the influence of external hexagon and Morse taper implants on peri-implant health in patients wearing mandibular overdentures for 1 year. Materials and Methods: A total of 46 implants were evaluated, 28 external hexagon and 18 Morse taper. Plaque index in the mini-abutment, bleeding index, peri-implant inflammation, keratinized mucosa zone, probing depth, and marginal mucosa level were evaluated after 3 months and 1 year of prostheses insertion. Results: Deeper probing was found in the external hexagon group compared with Morse taper (P = 0.024 after 1 year of rehabilitation. Although the Morse taper group exhibited worse scenario of peri-implant inflammation than the external hexagon group (P = 0.001, both groups showed reduced inflammation after 1 year. A larger keratinized mucosa zone was observed with external hexagon implants (P = 0.020. No significant difference was found between the groups for plaque index in the mini-abutment, bleeding index, and marginal mucosa level. Conclusion: In a follow-up period of 1 year, it was concluded that the external hexagon group had a larger probing depth than the Morse taper group. However, better periodontal conditions about inflammation and keratinized mucosa zone were found in external hexagon implants. It was found no influence of implant platform on plaque index in the mini-abutment, bleeding index, and marginal mucosa level.

  11. Simultaneous versus sequential bilateral cochlear implants in adults: Cost analysis in a US setting.

    Science.gov (United States)

    Trinidade, Aaron; Page, Joshua C; Kennett, Sarah W; Cox, Matthew D; Dornhoffer, John L

    2017-11-01

    From a purely surgical efficiency point of view, simultaneous cochlear implantation (SimCI) is more cost-effective than sequential cochlear implantation (SeqCI) when total direct costs are considered (implant and hospital costs). However, in a setting where only SeqCI is practiced and a proportion of initially unilaterally implanted patients do not progress to a second implant, this may not be the case, especially when audiological costs are factored in. We present a cost analysis of such a scenario as would occur in our institution. Retrospective review and cost analysis. Between 2005 and 2015, 370 patients fulfilled the audiological criteria for bilateral implantation. Of those, 267 (72.1%) underwent unilateral cochlear implantation only, 101 (27.3%) progressed to SeqCI, and two underwent SimCI. The total hospital, surgical, and implant costs, and initial implant stimulation series audiological costs between August 2015 and August 2016 (29 adult patients) were used in this analysis. The total hospital, surgical, and implant costs for this period was $2,731,360.42. Based on previous local trends, if a projected eight (27.3%) of these patients decide to progress to SeqCI, this will cost an additional $750,811.04, resulting in an overall total of $3,482,171.46 for these 29 patients. Had all 29 undergone SimCI, the total projected cost would have been $3,332,991.75, representing a total potential saving of $149,179.67 (4.3%). In institutions where only SeqCI is allowed in adults, overall patient management may cost marginally more than if SimCI were practiced. This will be of interest to CI programs and health insurance companies. 4. Laryngoscope, 127:2615-2618, 2017. © 2017 The American Laryngological, Rhinological and Otological Society, Inc.

  12. One-year results of maxillary overdentures supported by 2 titanium-zirconium implants - implant survival rates and radiographic outcomes.

    Science.gov (United States)

    Zembic, Anja; Tahmaseb, Ali; Jung, Ronald E; Wismeijer, Daniel

    2017-07-01

    To assess implant survival rates and peri-implant bone loss of 2 titanium-zirconium implants supporting maxillary overdentures at 1 year of loading. Twenty maxillary edentulous patients (5 women and 15 men) being dissatisfied with their complete dentures were included. In total, 40 diameter-reduced titanium-zirconium implants were placed in the anterior maxilla. Local guided bone regeneration (GBR) was allowed if the treatment did not compromise implant stability. Following 3 to 5 months of healing, implant-supported overdentures were inserted on two ball anchors. Implants and overdentures were assessed at 1, 2, 4, and 8 weeks after implant insertion and 2, 4, and 12 months after insertion of overdentures (baseline). Standardized radiographs were taken at implant loading and 1 year. Implant survival rates and bone loss were the primary outcomes. Nineteen patients (1 dropout) with 38 implants were evaluated at a mean follow-up of 1.1 years (range 1.0-1.7 years). One implant failed resulting in an implant survival rate of 97.3%. There was a significant peri-implant bone loss of the implants at 1 year of function (mean, 0.7 mm, SD = 1.1 mm; median: 0.48 mm, IQR = 0.56 mm). There was a high 1-year implant survival rate for edentulous patients receiving 2 maxillary implants and ball anchors as overdenture support. However, several implants exhibited an increased amount of bone loss of more than 2 mm. Overdentures supported by 2 maxillary implants should thus be used with caution as minimally invasive treatment for specific patients encountering problems with their upper dentures until more long-term data is available. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  13. The role of implantation damage in the production of silicon-on-insulator films by co-implantation of He+ and H+

    International Nuclear Information System (INIS)

    Venezia, V.C.; Agarwal, A.; Lucent Technologies, Murray Hill, NJ; Haynes, T.E.; Holland, O.W.; Eaglesham, D.J.; Weldon, M.K.; Chabal, Y.J.

    1998-01-01

    Recent work has demonstrated that the process of silicon thin film separation by hydrogen implantation, as well as the more basic phenomenon of surface blistering, can occur at a much lower total dose when H and He are co-implanted than when H is implanted alone. Building on that work, this paper investigates the role of implantation damage in this process by separating the contributions of gas pressure from those of damage. Three different experiments using co-implantation were designed. In the first of these experiments, H and He implants were spatially separated thereby separating the damage from each implant. The second experiment involved co-implantation of H and He at a temperature of 77 K to retain a larger amount of damage for the same gas dose. In the third experiment, Li was co-implanted with H, to create additional damage without introducing additional gas. These experiments together show that increasing the implantation damage itself hampers the formation of surface blisters, and that the increased efficiency observed for He co-implantation with H is due to the supplementary source of gas provided by the He

  14. Clinical outcomes of implant therapy in ectodermal dysplasia patients: a systematic review.

    Science.gov (United States)

    Wang, Y; He, J; Decker, A M; Hu, J C; Zou, D

    2016-08-01

    The purpose of this review was to determine the outcome of oral function reconstruction in ectodermal dysplasia (ED) patients who have received dental implant therapy. A search was made of the PubMed and Web of Science databases; key words used were "(ectodermal dysplasia) AND (implant OR implants)", with supplementary retrieval key words "dental implant", "zygomatic implant", "anodontia", and "edentulous". Patient age, use of bone graft, implant site, type of implant, and survival rate of the implants were included in the subsequent data analysis. Forty-five articles published between 1988 and October 2015 were included in this analysis. The cases of a total of 96 patients were retrieved (22 children and 74 adults); these patients received a total of 701 implants. Fourteen implants were removed during a median follow-up time of 24 months. The 24-month implant survival rate was 97.9% in adult subjects and 98.6% in children. Sixty-eight percent of adult patients underwent bone augmentation prior to implant placement. Based on this review, dental implants are commonly used in the oral reconstruction of ED patients. However, long-term data on bone augmentation and implant success are needed, as well as additional clinical evidence on bone resorption, the esthetic outcomes of implant therapy, and physiological considerations in ED patients. Copyright © 2016 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  15. Reliability of implant placement after virtual planning of implant positions using cone beam CT data and surgical (guide) templates.

    Science.gov (United States)

    Nickenig, Hans-Joachim; Eitner, Stephan

    2007-01-01

    We assessed the reliability of implant placement after virtual planning of implant positions using cone-beam CT data and surgical guide templates. A total of 102 patients (250 implants, 55.4% mandibular; mean patient age, 40.4 years) who had undergone implant treatment therapy in an armed forces dental clinic (Cologne, Germany) between July 1, 2005 and December 1, 2005. They were treated with a system that allows transfer of virtual planning to surgical guide templates. Only in eight cases the surgical guides were not used because a delayed implant placement was necessary. In four posterior mandibular cases, handling was limited because of reduced interocclusal distance, requiring 50% shortening of the drill guides. The predictability of implant size was high: only one implant was changed to a smaller diameter (because of insufficient bone). In all cases, critical anatomical structures were protected and no complications were detected in postoperative panoramic radiographs. In 58.1% (147) of the 250 implants, a flapless surgery plan was realized. Implant placement after virtual planning of implant positions using cone beam CT data and surgical templates can be reliable for preoperative assessment of implant size, position, and anatomical complications. It is also indicative of cases amenable to flapless surgery.

  16. Outcome of total knee replacement following explantation and cemented spacer therapy.

    Science.gov (United States)

    Ghanem, Mohamed; Zajonz, Dirk; Bollmann, Juliane; Geissler, Vanessa; Prietzel, Torsten; Moche, Michael; Roth, Andreas; Heyde, Christoph-E; Josten, Christoph

    2016-01-01

    Infection after total knee replacement (TKR) is one of the serious complications which must be pursued with a very effective therapeutic concept. In most cases this means revision arthroplasty, in which one-setting and two-setting procedures are distinguished. Healing of infection is the conditio sine qua non for re-implantation. This retrospective work presents an assessment of the success rate after a two-setting revision arthroplasty of the knee following periprosthetic infection. It further considers drawing conclusions concerning the optimal timing of re-implantation. A total of 34 patients have been enclosed in this study from September 2005 to December 2013. 35 re-implantations were carried out following explantation of total knee and implantation of cemented spacer. The patient's group comprised of 53% (18) males and 47% (16) females. The average age at re-implantation time was 72.2 years (ranging from 54 to 85 years). We particularly evaluated the microbial spectrum, the interval between explantation and re-implantation, the number of surgeries that were necessary prior to re-implantation as well as the postoperative course. We reported 31.4% (11) reinfections following re-implantation surgeries. The number of the reinfections declined with increasing time interval between explantation and re-implantation. Patients who developed reinfections were operated on (re-implantation) after an average of 4.47 months. Those patients with uncomplicated course were operated on (re-implantation) after an average of 6.79 months. Nevertheless, we noticed no essential differences in outcome with regard to the number of surgeries carried out prior to re-implantation. Mobile spacers proved better outcome than temporary arthrodesis with intramedullary fixation. No uniform strategy of treatment exists after peri-prosthetic infections. In particular, no optimal timing can be stated concerning re-implantation. Our data point out to the fact that a longer time interval between

  17. Outcome of total knee replacement following explantation and cemented spacer therapy

    Directory of Open Access Journals (Sweden)

    Ghanem, Mohamed

    2016-03-01

    Full Text Available Background: Infection after total knee replacement (TKR is one of the serious complications which must be pursued with a very effective therapeutic concept. In most cases this means revision arthroplasty, in which one-setting and two-setting procedures are distinguished. Healing of infection is the conditio sine qua non for re-implantation. This retrospective work presents an assessment of the success rate after a two-setting revision arthroplasty of the knee following periprosthetic infection. It further considers drawing conclusions concerning the optimal timing of re-implantation.Patients and methods: A total of 34 patients have been enclosed in this study from September 2005 to December 2013. 35 re-implantations were carried out following explantation of total knee and implantation of cemented spacer. The patient’s group comprised of 53% (18 males and 47% (16 females. The average age at re-implantation time was 72.2 years (ranging from 54 to 85 years. We particularly evaluated the microbial spectrum, the interval between explantation and re-implantation, the number of surgeries that were necessary prior to re-implantation as well as the postoperative course. Results: We reported 31.4% (11 reinfections following re-implantation surgeries. The number of the reinfections declined with increasing time interval between explantation and re-implantation. Patients who developed reinfections were operated on (re-implantation after an average of 4.47 months. Those patients with uncomplicated course were operated on (re-implantation after an average of 6.79 months. Nevertheless, we noticed no essential differences in outcome with regard to the number of surgeries carried out prior to re-implantation. Mobile spacers proved better outcome than temporary arthrodesis with intramedullary fixation.Conclusion: No uniform strategy of treatment exists after peri-prosthetic infections. In particular, no optimal timing can be stated concerning re-implantation

  18. Implantable Neural Interfaces for Sharks

    Science.gov (United States)

    2007-05-01

    technology for recording and stimulating from the auditory and olfactory sensory nervous systems of the awake, swimming nurse shark , G. cirratum (Figures...overlay of the central nervous system of the nurse shark on a horizontal MR image. Implantable Neural Interfaces for Sharks ...Neural Interfaces for Characterizing Population Responses to Odorants and Electrical Stimuli in the Nurse Shark , Ginglymostoma cirratum.” AChemS Abs

  19. Antibiotic use at dental implant placement.

    Science.gov (United States)

    Veitz-Keenan, Analia; Keenan, James R

    2015-06-01

    Cochrane Oral Health Groups Trial Register, Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE via OVID and EMBASE via OVID. Databases were searched with no language or date restrictions. Two authors independently reviewed the titles and the abstracts for inclusion. Disagreements were resolved by discussion. If needed, a third author was consulted. Included were randomised clinical trials with a follow-up of at least three months which evaluated the use of prophylactic antibiotic compared to no antibiotic or a placebo and examined different antibiotics of different doses and durations in patients undergoing dental implant placement. The outcomes were implant failure (considered as implant mobility, removal of implant due to bone loss or infection) and prosthesis failure (prosthesis could not be placed). Standard Cochrane methodology procedures were followed. Risk of bias was completed independently and in duplicate by two review authors. Results were expressed as risk ratios (RRs) using a random-effects model for dichotomous outcomes with 95% confidence intervals (CI). The statistical unit was the participant and not the prosthesis or implant. Heterogeneity including both clinical and methodological factors was investigated. Six randomised clinical trials with 1162 participants were identified for the review. Three trials compared 2 g of preoperative amoxicillin versus placebo (927 participants). One trial compared 3 g of preoperative amoxicillin versus placebo (55 participants). Another trial compared 1 g of preoperative amoxicillin plus 500 mg four times a day for two days versus no antibiotic (80 participants). An additional trial compared four groups: (1) 2 g of preoperative amoxicillin; (2) 2 g of preoperative amoxicillin plus 1 g twice a day for seven days; (3) 1 g of postoperative amoxicillin twice a day for seven days and (4) no antibiotics (100 participants). The overall body of the evidence was considered moderate.The meta-analysis of the

  20. Revision total hip arthoplasty: factors associated with re-revision surgery.

    Science.gov (United States)

    Khatod, Monti; Cafri, Guy; Inacio, Maria C S; Schepps, Alan L; Paxton, Elizabeth W; Bini, Stefano A

    2015-03-04

    The survivorship of implants after revision total hip arthroplasty and risk factors associated with re-revision are not well defined. We evaluated the re-revision rate with use of the institutional total joint replacement registry. The purpose of this study was to determine patient, implant, and surgeon factors associated with re-revision total hip arthroplasty. A retrospective cohort study was conducted. The total joint replacement registry was used to identify patients who had undergone revision total hip arthroplasty for aseptic reasons from April 1, 2001, to December 31, 2010. The end point of interest was re-revision total hip arthroplasty. Risk factors evaluated for re-revision total hip arthroplasty included: patient risk factors (age, sex, body mass index, race, and general health status), implant risk factors (fixation type, bearing surface, femoral head size, and component replacement), and surgeon risk factors (volume and experience). A multivariable Cox proportional hazards model was used. Six hundred and twenty-nine revision total hip arthroplasties with sixty-three (10%) re-revisions were evaluated. The mean cohort age (and standard deviation) was 57.0 ± 12.4 years, the mean body mass index (and standard deviation) was 29.5 ± 6.1 kg/m(2), and most of the patients were women (64.5%) and white (81.9%) and had an American Society of Anesthesiologists score of associated with the risk of re-revision. For every ten-year increase in patient age, the hazard ratio for re-revision decreases by a factor of 0.72 (95% confidence interval, 0.58 to 0.90). For every five revision surgical procedures performed by a surgeon, the risk of revision decreases by a factor of 0.93 (95% confidence interval, 0.86 to 0.99). At the time of revision, a new or retained cemented femoral implant or all-cemented hip implant increases the risk of revision by a factor of 3.19 (95% confidence interval, 1.22 to 8.38) relative to a retained or new uncemented hip implant. A ceramic on a

  1. Rehabilitation with implant-supported overdentures in total edentulous patients: A review

    OpenAIRE

    Martínez–Lage-Azorín, Juan F.; Segura-Andrés, Gustavo; Faus-López, Joan; Agustín-Panadero, Rubén

    2013-01-01

    Objectives: The main aim of this review article is to discuss implant-supported overdentures (ISOs) as treatment in edentulous patients. Besides, we will try to discuss among the different treatment options in such patients and to analyze their validity when ISOs are compared with other clinical modalities. At the same time, we will try to suggest clinical guidelines supported by current clinical studies. Material and methods: We performed a Medline search and review of pertinent articles on ...

  2. Idiopathic facial pain related with dental implantation

    Directory of Open Access Journals (Sweden)

    Tae-Geon Kwon

    2016-06-01

    Full Text Available Chronic pain after dental implantation is rare but difficult issue for the implant practitioner. Patients with chronic pain who had been performed previous implant surgery or related surgical intervention sometimes accompany with psychological problem and difficult to adequately manage. According to the International Classification of Headache Disorders (ICHD 3rd eds, Cepalagia 2013, painful neuropathies and other facial pains are subdivided into the 12 subcategories; 13.1. Trigeminal neuralgia; 13.2 Glossopharyngeal neuralgia; 13.3 Nervus intermedius (facial nerve neuralgia; 13.4 Occipital neuralgia; 13.5 Optic neuritis; 13.6 Headache attributed to ischaemic ocular motor nerve palsy; 13.7 Tolosa-Hunt syndrome; 13.8 Paratrigeminal oculo-sympathetic (Raeder’s syndrome; 13.9 Recurrent painful ophthalmoplegic neuropathy; 13.10 Burning Mouth Syndrome (BMS; 13.11 Persistent Idiopathic Facial Pain (PIFP; 13.12 Central neuropathic pain. Chronic orofacial pain after dental implant surgery can be largely into the two main categories that can be frequently encountered in clinical basis ; 1 Neuropathic pain, 2 Idiopathic pain. If there is no direct evidence of the nerve injury related with the implant surgery, the clinician need to consider the central cause of pain instead of the peripheral cause of the pain. There might be several possibilities; 1 Anaesthesia dolorosa, 2 Central post-stroke pain, 3 Facial pain attributed to multiple sclerosis, 4 Persistent idiopathic facial pain (PIFP, 5 Burning mouth syndrome. In this presentation, Persistent idiopathic facial pain (PIFP, the disease entity that can be frequently encountered in the clinic would be discussed. Persistent idiopathic facial pain (PIFP can be defined as “persistent facial and/or oral pain, with varying presentations but recurring daily for more than 2 hours per day over more than 3 months, in the absence of clinical neurological deficit”. ‘Atypical’ pain is a diagnosis of

  3. Different types of implants for reconstructive breast surgery.

    Science.gov (United States)

    Rocco, Nicola; Rispoli, Corrado; Moja, Lorenzo; Amato, Bruno; Iannone, Loredana; Testa, Serena; Spano, Andrea; Catanuto, Giuseppe; Accurso, Antonello; Nava, Maurizio B

    2016-05-16

    Breast cancer is the most common cancer in women worldwide, and is a leading cause of cancer death among women. Prophylactic or curative mastectomy is often followed by breast reconstruction for which there are several surgical approaches that use breast implants with which surgeons can restore the natural feel, size and shape of the breast. To assess the effects of different types of breast implants on capsular contracture, surgical short- and long-term complications, postoperative satisfaction level and quality of life in women who have undergone reconstructive breast surgery after mastectomy. We searched the Cochrane Breast Cancer Group's Specialised Register on 20 July 2015, MEDLINE (1985 to 20 July 2015), EMBASE (1985 to 20 July 2015) and the Cochrane Central Register of Controlled Trials (CENTRAL; Issue 8, 2015). We also searched the World Health Organization's International Clinical Trials Registry Platform (WHO ICTRP) and ClinicalTrials.gov on 16 July 2015. We included randomised controlled trials (RCTs) and quasi-RCTs that compared different types of breast implants for reconstructive surgery. We considered the following types of intervention: implant envelope surfaces - texturised versus smooth; implant filler material - silicone versus saline, PVP-Hydrogel versus saline; implant shape - anatomical versus round; implant volume - variable versus fixed; brands - different implant manufacturing companies and implant generation (fifth versus previous generations). Two review authors independently assessed methodological quality and extracted data. We used standard Cochrane methodological procedures. The quality of the evidence was assessed using the Grading of Recommendations Assessment, Development and Evaluation (GRADE) system. Five RCTs with 202 participants met the inclusion criteria. The women participants were typically in their 50s, and the majority of them (about 82%) received reconstructive surgery following breast cancer, while the others had

  4. Changes in resonance frequency analysis assessed by Osstell mentor during osseointegration: comparison between immediately loaded implants and control implants without load

    Directory of Open Access Journals (Sweden)

    M. González-Jaranay

    2014-10-01

    Full Text Available Aim: The aim of this prospective clinical study was to evaluate the changes in resonance frequency analysis (RFA, assessed by Osstell Mentor, obtaining information on the implant stability quotient (ISQ during implants tissue integration for immediately loaded and non-loaded control implants. Materials and methods: A total of 40 implants, 20 implants with no immediate loading (control and 20 immediately loaded implants (test, were placed in 15 patients. ISQ implants was evaluated at baseline and at 6 and 8 weeks. Provisional crowns were removed at 8 weeks, when the definitive restoration was placed. Data of control and test implants and maxillary and mandibular areas were statistically compared. Results: At 8 weeks, all implants were integrated and there were no major postoperative complications. A statistically significant difference was found only at baseline between test and control maxillary implants (p=0.009 but not at 6 or 8 weeks (p>0.05. Conclusion: Immediate loading procedures may be applied with primary stability ISQ values >60 and inserted with a force of ≥30 N. The Osstell Mentor RFA may offer an objective method to determine when implant stability is adequate for immediate loading.

  5. Bone remodelling of the proximal femur after total hip arthroplasty with 2 different hip implant designs

    DEFF Research Database (Denmark)

    Christiansen, Janus D.; Laursen, Mogens B; Ejaz, Ashir

    2018-01-01

    INTRODUCTION: The thrust plate prosthesis (TPP) was introduced to preserve bone in patients undergoing total hip arthroplasty. We assessed the long-term results of hip arthroplasty in patients who received the TPP compared to a traditional intramedullary stem (Bi-Metric). METHODS......: In this prospective observational cohort study, we evaluated bone mineral density (BMD) using dual-energy X-ray absorptiometry (DXA), radiological imaging and clinical outcome using Harris Hip Score (HHS). Twenty patients received the TPP (group A) and 18 patients received the Bi-Metric stem (group B). Baseline......% (95% confidence interval [CI], 4-16; p = 0.003) and 8% (95% CI, 1-15; p = 0.03) at 8 years. Regarding ROI4, group A had a lesser decrease in general compared to group B. The radiological findings did not reveal any subsidence or detectable implant migration. HHS improved from 53 (23-69) to 93 (55...

  6. Manejo do cateter venoso central totalmente implantado em pacientes oncológicos: revisão integrative Manejo del catéter venoso central totalmente implantado en pacientes oncológicos: revisión integrativa Management of totally implanted catheter in patients with cancer: an integrative review

    Directory of Open Access Journals (Sweden)

    Christiane Inocêncio Vasques

    2009-10-01

    Full Text Available O cateter totalmente implantado é amplamente utilizado durante o tratamento de pacientes com câncer e é capaz de minimizar complicações decorrentes da terapia intravenosa periférica. Assim, buscou-se identificar os cuidados de enfermagem relacionados ao manuseio de cateter totalmente implantado nesses pacientes. Para tanto, realizou-se revisão integrativa da literatura que resultou na análise de 15 artigos. O conhecimento produzido está direcionado para o tempo de permanência do cateter, complicações inerentes ao uso, manuseio do dispositivo, percepção do paciente em relação ao cateter e informações ao paciente. Além de demonstrar a complexidade da assistência de enfermagem no manuseio desses dispositivos, os achados podem auxiliar, igualmente, os profissionais que não atuam em oncologia, na aplicação de conhecimentos na prática clínica.El catéter totalmente implantado es ampliamente utilizado durante el tratamiento de pacientes con cáncer y es capaz de minimizar las complicaciones consecuentes de la terapia intravenosa periférica. Así, en este trabajo, se buscó identificar los cuidados de enfermería relacionados a la manipulación del catéter totalmente implantado en esos pacientes. Para tal efecto, se realizó una revisión integrativa de la literatura dando como resultado el análisis de 15 artículos. El conocimiento producido está orientado hacia el tiempo de permanencia del catetér, complicaciones inherentes al uso, manipulación del dispositivo, informaciones y percepción del paciente en relación al catéter. Aparte de demostrar la complejidad de la asistencia de enfermería en la manipulación de esos dispositivos, los hallazgos pueden auxiliar, igualmente, a los profesionales que no actúan en oncología, en la aplicación de conocimientos en la práctica clínica.Totally implanted catheter, which is effective in deceasing complications related to peripheral intravenous therapy, is widely used in

  7. Comparing Short Dental Implants to Standard Dental Implants: Protocol for a Systematic Review.

    Science.gov (United States)

    Rokn, Amir Reza; Keshtkar, Abbasali; Monzavi, Abbas; Hashemi, Kazem; Bitaraf, Tahereh

    2018-01-18

    Short dental implants have been proposed as a simpler, cheaper, and faster alternative for the rehabilitation of atrophic edentulous areas to avoid the disadvantages of surgical techniques for increasing bone volume. This review will compare short implants (4 to 8 mm) to standard implants (larger than 8 mm) in edentulous jaws, evaluating on the basis of marginal bone loss (MBL), survival rate, complications, and prosthesis failure. We will electronically search for randomized controlled trials comparing short dental implants to standard dental implants in the following databases: PubMed, Web of Science, EMBASE, Scopus, the Cochrane Central Register of Controlled Trials, and ClinicalTrials.gov with English language restrictions. We will manually search the reference lists of relevant reviews and the included articles in this review. The following journals will also be searched: European Journal of Oral Implantology, Clinical Oral Implants Research, and Clinical Implant Dentistry and Related Research. Two reviewers will independently perform the study selection, data extraction and quality assessment (using the Cochrane Collaboration tool) of included studies. All meta-analysis procedures including appropriate effect size combination, sub-group analysis, meta-regression, assessing publication or reporting bias will be performed using Stata (Statacorp, TEXAS) version 12.1. Short implant effectiveness will be assessed using the mean difference of MBL in terms of weighted mean difference (WMD) and standardized mean difference (SMD) using Cohen's method. The combined effect size measures in addition to the related 95% confidence intervals will be estimated by a fixed effect model. The heterogeneity of the related effect size will be assessed using a Q Cochrane test and I2 measure. The MBL will be presented by a standardized mean difference with a 95% confidence interval. The survival rate of implants, prostheses failures, and complications will be reported using a risk

  8. Trabeculectomy with Ex-PRESS implant versus Ahmed glaucoma valve implantation-a comparative study

    Science.gov (United States)

    Waisbourd, Michael; Fischer, Naomi; Shalev, Hadas; Spierer, Oriel; Ben Artsi, Elad; Rachmiel, Rony; Shemesh, Gabi; Kurtz, Shimon

    2016-01-01

    AIM To compare the surgical outcomes of trabeculectomy with Ex-PRESS implant and Ahmed glaucoma valve (AGV) implantation. METHODS Patients who underwent trabeculectomy with Ex-PRESS implants or AGV implantation separately were included in this retrospective chart review. Main outcome measures were surgical failure and complications. Failure was defined as intraocular pressure (IOP) >21 mm Hg or glaucoma, or loss of light perception. Eyes that had not failed were considered as complete success if they did not required supplemental medical therapy. RESULTS A total of 64 eyes from 57 patients were included: 31 eyes in the Ex-PRESS group and 33 eyes in the AGV group. The mean follow-up time was 2.6±1.1y and 3.3±1.6y, respectively. Patients in the AGV group had significantly higher baseline mean IOP (P=0.005), lower baseline mean visual acuity (VA) (P=0.02), and higher proportion of patients with history of previous trabeculectomy (Pglaucoma surgeries. Therefore, the results are limited to the cohort included in this study. PMID:27803857

  9. Ion implantation for semiconductors

    International Nuclear Information System (INIS)

    Grey-Morgan, T.

    1995-01-01

    Full text: Over the past two decades, thousands of particle accelerators have been used to implant foreign atoms like boron, phosphorus and arsenic into silicon crystal wafers to produce special embedded layers for manufacturing semiconductor devices. Depending on the device required, the atomic species, the depth of implant and doping levels are the main parameters for the implantation process; the selection and parameter control is totally automated. The depth of the implant, usually less than 1 micron, is determined by the ion energy, which can be varied between 2 and 600 keV. The ion beam is extracted from a Freeman or Bernas type ion source and accelerated to 60 keV before mass analysis. For higher beam energies postacceleration is applied up to 200 keV and even higher energies can be achieved by mass selecting multiplycharged ions, but with a corresponding reduction in beam output. Depending on the device to be manufactured, doping levels can range from 10 10 to 10 15 atoms/cm 2 and are controlled by implanter beam currents in the range up to 30mA; continuous process monitoring ensures uniformity across the wafer of better than 1 % . As semiconductor devices get smaller, additional sophistication is required in the design of the implanter. The silicon wafers charge electrically during implantation and this charge must be dissipated continuously to reduce the electrical stress in the device and avoid destructive electrical breakdown. Electron flood guns produce low energy electrons (below 10 electronvolts) to neutralize positive charge buildup and implanter design must ensure minimum contamination by other isotopic species and ensure low internal sputter rates. The pace of technology in the semiconductor industry is such that implanters are being built now for 256 Megabit circuits but which are only likely to be widely available five years from now. Several specialist companies manufacture implanter systems, each costing around US$5 million, depending on the

  10. Failed total carpometacarpal joint prosthesis of the thumb

    DEFF Research Database (Denmark)

    Hansen, Torben Bæk; Homilius, Morten

    2010-01-01

    Total joint prosthesis in carpometacarpal joint arthritis of the thumb often fails. Loosening of the implant is often treated by resection arthroplasty, and we reviewed 10 patients, mean age 54 years (range 47-63) who were treated by resection arthroplasty after a failed total joint prosthesis. T...... in eight of 10 patients, but the mean Disabilities of the arm, shoulder, and hand (DASH) scores, self-reported pinch-grip-related function, and pain were comparable with our earlier published results with the Elektra carpometacarpal total joint prosthesis.......Total joint prosthesis in carpometacarpal joint arthritis of the thumb often fails. Loosening of the implant is often treated by resection arthroplasty, and we reviewed 10 patients, mean age 54 years (range 47-63) who were treated by resection arthroplasty after a failed total joint prosthesis....... The male:female ratio was 1:4 and the mean duration of observation 32 months (range 6-52). In three patients the revised implant was a MOJE uncemented carpometacarpal joint prosthesis and in seven patients an Elektra uncemented one. At follow-up grip strength was reduced to less than 90% of the other hand...

  11. Incidence and risk factors for central venous access port-related infection in Chinese cancer patients.

    Science.gov (United States)

    Wang, Ting-Yao; Lee, Kuan-Der; Chen, Ping-Tsung; Chen, Min-Chi; Chen, Yi-Yang; Huang, Cih-En; Kuan, Feng-Che; Chen, Chih-Cheng; Lu, Chang Hsien

    2015-11-01

    Cytotoxic chemotherapy via central venous access ports is an important part of the standard treatment for most cancers, but it is accompanied with the risk of infections. This study aimed to analyze the incidence and risk factors for central venous access port-related infection (CPI) among Chinese patients receiving cytotoxic chemotherapy. Between January 1, 2002 and December 31, 2005 a total of 1391 cancer patients with 1449 totally implantable central venous access ports were evaluated. The log-rank test and Cox proportional hazards model were used for the analyses of risk factors. The overall CPI incidence rate was 0.21 per 1000 catheter-days. Hematological malignancies and head and neck cancer were associated with an increased risk of CPI (hazard ratio 4.00 and 4.11, respectively, both p risk of infection than for patients in a nonadjuvant setting (p ports. Implementation of an insertion bundle for the prevention of central line-associated bloodstream infections is warranted, especially for those patients with hematological and head and neck cancers, as well as for patients receiving chemotherapy in the metastatic settings. Copyright © 2015. Published by Elsevier B.V.

  12. Auditory and audio-visual processing in patients with cochlear, auditory brainstem, and auditory midbrain implants: An EEG study.

    Science.gov (United States)

    Schierholz, Irina; Finke, Mareike; Kral, Andrej; Büchner, Andreas; Rach, Stefan; Lenarz, Thomas; Dengler, Reinhard; Sandmann, Pascale

    2017-04-01

    There is substantial variability in speech recognition ability across patients with cochlear implants (CIs), auditory brainstem implants (ABIs), and auditory midbrain implants (AMIs). To better understand how this variability is related to central processing differences, the current electroencephalography (EEG) study compared hearing abilities and auditory-cortex activation in patients with electrical stimulation at different sites of the auditory pathway. Three different groups of patients with auditory implants (Hannover Medical School; ABI: n = 6, CI: n = 6; AMI: n = 2) performed a speeded response task and a speech recognition test with auditory, visual, and audio-visual stimuli. Behavioral performance and cortical processing of auditory and audio-visual stimuli were compared between groups. ABI and AMI patients showed prolonged response times on auditory and audio-visual stimuli compared with NH listeners and CI patients. This was confirmed by prolonged N1 latencies and reduced N1 amplitudes in ABI and AMI patients. However, patients with central auditory implants showed a remarkable gain in performance when visual and auditory input was combined, in both speech and non-speech conditions, which was reflected by a strong visual modulation of auditory-cortex activation in these individuals. In sum, the results suggest that the behavioral improvement for audio-visual conditions in central auditory implant patients is based on enhanced audio-visual interactions in the auditory cortex. Their findings may provide important implications for the optimization of electrical stimulation and rehabilitation strategies in patients with central auditory prostheses. Hum Brain Mapp 38:2206-2225, 2017. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  13. PIP breast implant removal: a study of 828 cases.

    Science.gov (United States)

    Oulharj, S; Pauchot, J; Tropet, Y

    2014-03-01

    In March, 2010, the French Health Products Safety Agency suspended the sale of prefilled silicone breast implants manufactured by Poly Implants Prosthèse Prothese (PIP) because of a high failure rate and the use of an inappropriate silicone gel that did not comply with CE marking. These findings led to an international medical crisis. In France, 30,000 female patients had PIP implants. In our Department, 1150 PIP breast implants had been implanted in 630 patients since 2001. A retrospective study was conducted to define the rupture rate of these implants and the complications that arise. The women included in the study underwent implant removal from May 2010 to September 2012 for preventive or curative reasons. Data were collected from medical records that included: results of clinical examination, breast ultrasound before removal, rates of implant rupture, results of biopsy of periprosthetic capsule and pericapsule tissue and postoperative complications. A total of 828 PIP breast implants were removed in 455 patients. The rate of ruptured implants was 7.73% (64/828), corresponding to 11.6% of patients. A periprosthetic effusion was associated with rupture in 44% of cases. Breast ultrasound indicated a rupture for 87 implants; 32% were true positives and 3% were false negatives. Periprosthetic capsule biopsy demonstrated the presence of a foreign body, which seemed to be silicone, in 26% of cases and the presence of inflammation in 13% of cases. No siliconoma-type lesion was identified in the pericapsular tissue at biopsy. A total of 14 implants presented perspiration at removal. A statistically significant difference was found between the rates of rupture for texturised implants as compared to the smooth-surfaced implants. There were eight post-revisional-surgery complications (1%) and three cases of breast adenocarcinoma. The preventive explantation of PIP breast implants is justified given the high failure rate (7.73%) and given patients' exposure to silicone

  14. Short Implants: New Horizon in Implant Dentistry.

    Science.gov (United States)

    Jain, Neha; Gulati, Manisha; Garg, Meenu; Pathak, Chetan

    2016-09-01

    The choice of implant length is an essential factor in deciding the survival rates of these implants and the overall success of the prosthesis. Placing an implant in the posterior part of the maxilla and mandible has always been very critical due to poor bone quality and quantity. Long implants can be placed in association with complex surgical procedures such as sinus lift and bone augmentation. These techniques are associated with higher cost, increased treatment time and greater morbidity. Hence, there is need for a less invasive treatment option in areas of poor bone quantity and quality. Data related to survival rates of short implants, their design and prosthetic considerations has been compiled and structured in this manuscript with emphasis on the indications, advantages of short implants and critical biomechanical factors to be taken into consideration when choosing to place them. Studies have shown that comparable success rates can be achieved with short implants as those with long implants by decreasing the lateral forces to the prosthesis, eliminating cantilevers, increasing implant surface area and improving implant to abutment connection. Short implants can be considered as an effective treatment alternative in resorbed ridges. Short implants can be considered as a viable treatment option in atrophic ridge cases in order to avoid complex surgical procedures required to place long implants. With improvement in the implant surface geometry and surface texture, there is an increase in the bone implant contact area which provides a good primary stability during osseo-integration.

  15. EARLY AND LATE COMPLICATIONS RELATED TO CENTRAL VENOUS CATHETERS IN HAEMATOLOGICAL MALIGNANCIES: A RETROSPECTIVE ANALYSIS OF 1102 PATIENTS

    Directory of Open Access Journals (Sweden)

    Salvatore Giacomo Morano

    2014-02-01

    Full Text Available Several severe complications may be associated with the use of central venous catheters (CVC. We retrospectively evaluated on a large cohort of patients the incidence of CVC-related early and late complications. From 7/99 to 12/2005, 1102 CVC have been implanted at our Institution in 881 patients with haematological malignancies (142,202 total day number of implanted CVC. Early mechanic complications were 79 (7.2% - 0.55/1,000 days/CVC. Thirty-nine episodes of early infective complications (<1 week from CVC implant occurred (3.5% - 0.3/1000 days/CVC: furthermore, 187 episodes of CVC-related sepsis (17% - 1.3/1000 days/CVC were recorded. There were 29 episodes (2.6% of symptomatic CVC-related thrombotic complications, with a median interval from CVC implant of 60 days (range 7 – 395. The rate of CVC withdrawal due to CVC-related complications was 26%. The incidence of CVC-related complications in our series is in the range reported in the literature, notwithstanding cytopenia often coexisting in haematological patients.

  16. Influence of Palatal Coverage and Implant Distribution on Implant Strain in Maxillary Implant Overdentures.

    Science.gov (United States)

    Takahashi, Toshihito; Gonda, Tomoya; Mizuno, Yoko; Fujinami, Yozo; Maeda, Yoshinobu

    2016-01-01

    Maxillary implant overdentures are often used in clinical practice. However, there is no agreement or established guidelines regarding prosthetic design or optimal implant placement configuration. The purpose of this study was to examine the influence of palatal coverage and implant number and distribution in relation to impact strain under maxillary implant overdentures. A maxillary edentulous model with implants and experimental overdentures with and without palatal coverage was fabricated. Four strain gauges were attached to each implant, and they were positioned in the anterior, premolar, and molar areas. A vertical occlusal load of 98 N was applied through a mandibular complete denture, and the implant strains were compared using one-way analysis of variance (P = .05). The palatolabial strain was much higher on anterior implants than on other implants in both denture types. Although there was no significant difference between the strain under dentures with and without palatal coverage, palateless dentures tended to result in higher implant strain than dentures with palatal coverage. Dentures supported by only two implants registered higher strain than those supported by four or six implants. Implants under palateless dentures registered higher strain than those under dentures with palatal coverage. Anterior implants exhibited higher palatolabial strain than other implants regardless of palatal coverage and implant configuration; it is therefore recommended that maxillary implant overdentures should be supported by six implants with support extending to the distal end of the arch.

  17. Ultrasonic implant site preparation using piezosurgery: a multicenter case series study analyzing 3,579 implants with a 1- to 3-year follow-up.

    Science.gov (United States)

    Vercellotti, Tomaso; Stacchi, Claudio; Russo, Crescenzo; Rebaudi, Alberto; Vincenzi, Giampaolo; Pratella, Umberto; Baldi, Domenico; Mozzati, Marco; Monagheddu, Chiara; Sentineri, Rosario; Cuneo, Tommaso; Di Alberti, Luca; Carossa, Stefano; Schierano, Gianmario

    2014-01-01

    This multicenter case series introduces an innovative ultrasonic implant site preparation (UISP) technique as an alternative to the use of traditional rotary instruments. A total of 3,579 implants were inserted in 1,885 subjects, and the sites were prepared using a specific ultrasonic device with a 1- to 3-year follow-up. No surgical complications related to the UISP protocol were reported for any of the implant sites. Seventy-eight implants (59 maxillary, 19 mandibular) failed within 5 months of insertion, for an overall osseointegration percentage of 97.82% (97.14% maxilla, 98.75% mandible). Three maxillary implants failed after 3 years of loading, with an overall implant survival rate of 97.74% (96.99% maxilla, 98.75% mandible).

  18. Evaluation of an expence of materials during ion implantation

    International Nuclear Information System (INIS)

    Bannikov, M.G.; Zlobin, N.; Zotov, A.V.; Vasilev, V.I.; Vasilev, I.P.

    2003-01-01

    Ion implantation is used for a surface modification. The implantation dose must be sufficient to obtain the required properties of a processed surface, but should not be exceeded to prevent over-expenditure of implanted materials. The latter is especially important when noble metals are used as an implanted material. The ion implanter includes a vacuum chamber, source of metal ions (target) and a vacuum pumping-out system. Ions of a plasma-forming gas sputter the target and ions of metal are then accelerated and implanted into surface treated. Ion implantation dose can be calculated from operation parameters such as ion beam current density and duration of implanting. The presence of the plasma-forming gas in the ion flow makes it difficult to determine the expenditure of an implanted metal itself. The objective of this paper is the more accurate definition of an expense of an implanted metal. Mass- spectrometric analysis of an ion beam together with the weighing of the target was used to determine the expense of an implanted metal. It was found that, depending on the implantation parameters, on average around 50% of a total ion flow are metal ions. Results obtained allow more precise definition of an implantation dose. Thus, over- expenditure of implanted metals can be eliminated. (author)

  19. A New Detection Method for Submerged Implants: Oral Tattoo.

    Science.gov (United States)

    Soylu, Emrah; Gönen, Zeynep Burçin; Alkan, Alper

    2018-04-01

    To evaluate the marking potential of tattoo ink in determining the definitive locations of submerged implants at the time of surgical exposure of the implants. In total, 104 implants in 32 patients were included in this study. After placement of the implants, cover screws were inserted. Overlying mucosa was marked with tattoo ink using a 20 g needle through the center of the cover screw. At the time of surgical exposure the tattoo marks were evaluated relative to visibility. At the time of the surgical exposures, tattoo ink was clearly visible at 91 implants, slightly visible at 8 implants, and not visible at 5 implants. After detection and classification of tattoo ink, the overlying mucosa was gently removed by tissue punch under local anesthesia. The results of this study seemed to indicate that marking the location of implants with tattoos at the time of implant placement can be an inexpensive, easy, healthy, and practical way to identify the location of marked submerged dental implants. © 2016 by the American College of Prosthodontists.

  20. Implant stability and marginal bone level of microgrooved zirconia dental implants: A 3-month experimental study on dogs

    Directory of Open Access Journals (Sweden)

    Delgado-Ruíz Rafael Arcesio

    2014-01-01

    Full Text Available Background/Aim. The modification of implant surfaces could affect mechanical implant stability as well as dynamics and quality of peri-implant bone healing. The aim of this 3-month experimental study in dogs was to investigate implant stability, marginal bone levels and bone tissue response to zirconia dental implants with two laser-micro-grooved intraosseous surfaces in comparison with nongrooved sandblasted zirconia and sandblasted, high-temperature etched titanium implants. Methods. Implant surface characterization was performed using optical interferometric profilometry and energy dispersive X-ray spectroscopy. A total of 96 implants (4 mm in diameter and 10 mm in length were inserted randomly in both sides of the lower jaw of 12 Fox Hound dogs divided into groups of 24 each: the control (titanium, the group A (sandblasted zirconia, the group B (sandblasted zirconia plus microgrooved neck and the group C (sandblasted zirconia plus all microgrooved. All the implants were immediately loaded. Insertion torque, periotest values, radiographic crestal bone level and removal torque were recorded during the 3-month follow-up. Qualitative scanning electon micro-scope (SEM analysis of the bone-implant interfaces of each group was performed. Results. Insertion torque values were higher in the group C and control implants (p the control > the group B > the group A (p the control > the group B > the group A (p < 0.05. SEM showed that implant surfaces of the groups B and C had an extra bone growth inside the microgrooves that corresponded to the shape and direction of the microgrooves. Conclusion. The addition of micro-grooves to the entire intraosseous surface of zirconia dental implants enhances primary and secondary implant stability, promotes bone tissue ingrowth and preserves crestal bone levels.

  1. Effect of implant macro-design on primary stability: A prospective clinical study

    OpenAIRE

    Lozano-Carrascal, Naroa; Salom?-Coll, Oscar; Gilabert-Cerd?, Marta; Farr?-Pag?s, Nuria; Gargallo-Albiol, Jordi; Hern?ndez-Alfaro, Federico

    2016-01-01

    Background Implant restorations have become a high predictable treatment option. Several caracteristics such as surgical technique and implant design can influence the treatment outcomes. The aim of the present study was to evaluate the influence of implant macro-design on primary stability measured with resonance frequency analysis (RFA) and insertion torque (IT). Material and Methods A total of 47 implants divided in two groups: Test group (TI): 22 Tapered MIS? Seven implants; Control group...

  2. Preservation of keratinized mucosa around implants using a prefabricated implant-retained stent: a case-control study

    Science.gov (United States)

    2016-01-01

    Purpose The aim of this study was to clinically assess the impact of a prefabricated implant-retained stent clipped over healing abutments on the preservation of keratinized mucosa around implants after implant surgery, and to compare it with horizontal external mattress sutures. Methods A total of 50 patients were enrolled in this study. In the test group, a prefabricated implant-retained stent was clipped on the healing abutment after implant surgery to replace the keratinized tissue bucco-apically. In the control group, horizontal external mattress sutures were applied instead of using a stent. After the surgical procedure, the width of the buccal keratinized mucosa was measured at the mesial, middle, and distal aspects of the healing abutment. The change in the width of the buccal keratinized mucosa was assessed at 1 and 3 months. Results Healing was uneventful in both groups. The difference of width between baseline and 1 month was −0.26±0.85 mm in the test group, without any statistical significance (P=0.137). Meanwhile, the corresponding difference in the control group was −0.74±0.73 mm and it showed statistical significance (Pprefabricated implant-retained stent was shown to be effective in the preservation of the keratinized mucosa around implants and it was simple and straightforward in comparison to the horizontal external mattress suture technique. PMID:27800215

  3. Optimal needle arrangement for intraoperative planning in permanent I-125 prostate implants

    International Nuclear Information System (INIS)

    Thompson, S.A.; Fung, A.Y.C.; Zaider, M.

    2002-01-01

    One limitation of intraoperative planning of permanent prostate implants is that needles must already be in the gland before planning images are acquired. Improperly placed needles often restrict the capability of generating optimal seed placement. We developed guiding principles for the proper layout of needles within the treatment volume. The Memorial Sloan-Kettering Cancer Center planning system employs a genetic algorithm to find the optimal seed implantation pattern consistent with pre-assigned constraints (needle geometry, uniformity, conformity and the avoidance of high doses to urethra and rectum). Ultrasound volumes for twelve patients with I-125 implants were used to generate six plans per patient (total 72 plans) with different needle arrangements. The plans were evaluated in terms of V100 (percentage prostate volume receiving at least the prescription dose), U135 (percentage urethra volume receiving at least 135% of prescription dose), and CI (conformity index, the ratio of treatment volume to prescription dose volume.) The method termed POSTCTR, in which needles were placed on the periphery of the largest ultrasound slice and posterior central needles were placed as needed, consistently gave superior results for all prostate sizes. Another arrangement, labelled POSTLAT, where the needles were placed peripherally with additional needles in the posterior lateral lobes, also gave satisfactory results. We advocate two needle arrangements, POSTCTR and POSTLAT, with the former giving better results. (author)

  4. Optimal needle arrangement for intraoperative planning in permanent I-125 prostate implants

    Energy Technology Data Exchange (ETDEWEB)

    Thompson, S.A. [Department of Medical Physics, North Shore-Long Island Jewish Health System, Manhassett, NY (United States); Fung, A.Y.C.; Zaider, M. [Department of Medical Physics, Memorial Sloan-Kettering Cancer Center, New York, NY (United States)

    2002-08-21

    One limitation of intraoperative planning of permanent prostate implants is that needles must already be in the gland before planning images are acquired. Improperly placed needles often restrict the capability of generating optimal seed placement. We developed guiding principles for the proper layout of needles within the treatment volume. The Memorial Sloan-Kettering Cancer Center planning system employs a genetic algorithm to find the optimal seed implantation pattern consistent with pre-assigned constraints (needle geometry, uniformity, conformity and the avoidance of high doses to urethra and rectum). Ultrasound volumes for twelve patients with I-125 implants were used to generate six plans per patient (total 72 plans) with different needle arrangements. The plans were evaluated in terms of V100 (percentage prostate volume receiving at least the prescription dose), U135 (percentage urethra volume receiving at least 135% of prescription dose), and CI (conformity index, the ratio of treatment volume to prescription dose volume.) The method termed POSTCTR, in which needles were placed on the periphery of the largest ultrasound slice and posterior central needles were placed as needed, consistently gave superior results for all prostate sizes. Another arrangement, labelled POSTLAT, where the needles were placed peripherally with additional needles in the posterior lateral lobes, also gave satisfactory results. We advocate two needle arrangements, POSTCTR and POSTLAT, with the former giving better results. (author)

  5. Echocardiographic and clinical outcomes of central versus noncentral percutaneous edge-to-edge repair of degenerative mitral regurgitation

    DEFF Research Database (Denmark)

    Estévez-Loureiro, Rodrigo; Franzen, Olaf; Winter, Reidar

    2013-01-01

    This study aimed to assess the clinical and echocardiographic results of MitraClip implantation in noncentral degenerative mitral regurgitation (dMR) compared with central dMR.......This study aimed to assess the clinical and echocardiographic results of MitraClip implantation in noncentral degenerative mitral regurgitation (dMR) compared with central dMR....

  6. Ultrasound guided implantation of chest port systems via the lateral subclavian vein

    International Nuclear Information System (INIS)

    Zaehringer, M.; Hilgers, J.; Krueger, K.; Strohe, D.; Bangard, C.; Neumann, L.; Lackner, K.; Warm, M.; Reiser, M.; Toex, U.

    2006-01-01

    Purpose: Retrospective analysis of the success and complication rates of chest port implantation via the lateral subclavian vein. Materials and methods: Between January 2003 and June 2004, the lateral subclavian vein in 271 patients (186 women, 85 men, mean age 53.2 years) was punctured guided by ultrasound. This access was used to insert a port system, and the catheter tip was placed at the cavoatrial junction. The port reservoir was implanted in a subcutaneous infraclavicular pocket and fixed to the fascia of the pectoralis muscle. Indications for port implantation were chemotherapy (n=239), total parenteral nutrition (n=2) and intravenous medication (n=30). The patient follow-up was mainly performed either by the oncology division of the department of gynecology or by the department of internal medicine. Results: A chest port catheter system was successfully implanted in all patients. The catheter remained in place for a mean duration of 269.4 days (SD 192.3 days). No complications occurred during implantation. In the post-interventional period, 6 catheter dysfunctions were found (thrombotic 0.09 per 1000 catheter days; mechanic 0.05 per 1000 catheter days). While one local infection occurred in the early post-interventional period, 3 local and 15 systemic infections were independent of the port catheter placement (0.39 per 1000 catheter days). The rate of port catheter explantations due to dysfunction or infection was 0.07 per 1000 catheter days. Conclusion: Ultrasound-guided puncture of the lateral subclavian vein is a safe procedure for the insertion of central venous port catheter systems and had a very low complication rate in our study. For further evaluation of our port placement technique, prospective studies compared to placement through the internal jugular vein are necessary. (orig.)

  7. Cochlear Implant

    Directory of Open Access Journals (Sweden)

    Mehrnaz Karimi

    1992-04-01

    Full Text Available People with profound hearing loss are not able to use some kinds of conventional amplifiers due to the nature of their loss . In these people, hearing sense is stimulated only when the auditory nerve is activated via electrical stimulation. This stimulation is possible through cochlear implant. In fact, for the deaf people who have good mental health and can not use surgical and medical treatment and also can not benefit from air and bone conduction hearing aids, this device is used if they have normal central auditory system. The basic parts of the device included: Microphone, speech processor, transmitter, stimulator and receiver, and electrode array.

  8. Regular and platform switching: bone stress analysis varying implant type.

    Science.gov (United States)

    Gurgel-Juarez, Nália Cecília; de Almeida, Erika Oliveira; Rocha, Eduardo Passos; Freitas, Amílcar Chagas; Anchieta, Rodolfo Bruniera; de Vargas, Luis Carlos Merçon; Kina, Sidney; França, Fabiana Mantovani Gomes

    2012-04-01

    This study aimed to evaluate stress distribution on peri-implant bone simulating the influence of platform switching in external and internal hexagon implants using three-dimensional finite element analysis. Four mathematical models of a central incisor supported by an implant were created: External Regular model (ER) with 5.0 mm × 11.5 mm external hexagon implant and 5.0 mm abutment (0% abutment shifting), Internal Regular model (IR) with 4.5 mm × 11.5 mm internal hexagon implant and 4.5 mm abutment (0% abutment shifting), External Switching model (ES) with 5.0 mm × 11.5 mm external hexagon implant and 4.1 mm abutment (18% abutment shifting), and Internal Switching model (IS) with 4.5 mm × 11.5 mm internal hexagon implant and 3.8 mm abutment (15% abutment shifting). The models were created by SolidWorks software. The numerical analysis was performed using ANSYS Workbench. Oblique forces (100 N) were applied to the palatal surface of the central incisor. The maximum (σ(max)) and minimum (σ(min)) principal stress, equivalent von Mises stress (σ(vM)), and maximum principal elastic strain (ε(max)) values were evaluated for the cortical and trabecular bone. For cortical bone, the highest stress values (σ(max) and σ(vm) ) (MPa) were observed in IR (87.4 and 82.3), followed by IS (83.3 and 72.4), ER (82 and 65.1), and ES (56.7 and 51.6). For ε(max), IR showed the highest stress (5.46e-003), followed by IS (5.23e-003), ER (5.22e-003), and ES (3.67e-003). For the trabecular bone, the highest stress values (σ(max)) (MPa) were observed in ER (12.5), followed by IS (12), ES (11.9), and IR (4.95). For σ(vM), the highest stress values (MPa) were observed in IS (9.65), followed by ER (9.3), ES (8.61), and IR (5.62). For ε(max) , ER showed the highest stress (5.5e-003), followed by ES (5.43e-003), IS (3.75e-003), and IR (3.15e-003). The influence of platform switching was more evident for cortical bone than for trabecular bone, mainly for the external hexagon

  9. Patient satisfaction with maxillary 3-implant overdentures using different attachment systems opposing mandibular 2-implant overdentures.

    Science.gov (United States)

    Al-Zubeidi, Mohammed I; Alsabeeha, Nabeel H M; Thomson, W Murray; Payne, Alan G T

    2012-05-01

    Patient-based outcomes with maxillary overdentures on a minimum number of implants, opposing mandibular 2-implant overdentures are not evident in the literature. To evaluate patient's satisfaction with maxillary 3-implant overdentures, opposing mandibular 2-implant overdentures, using two different attachment systems over the first 2 years of service. Forty participants wearing mandibular 2-implant overdentures for 3 years were randomly allocated to one of two similar implant system groups to receive maxillary 3-implant overdentures. Twenty participants were allocated to splinted and unsplinted attachment system treatment groups for each system. Patient satisfaction with pre-treatment complete maxillary dentures, with maxillary 3-implant overdentures at baseline and annually for 2 years, was measured using visual analogue scale questionnaires and the oral health impact profiles. Palatal coverage of the maxillary overdentures was reduced at the first annual recall. Data showed significant improvement in pain reduction, comfort, stability, and function variables of the visual analogue scale after treatment. Analysis by prosthodontic design using visual analogue scale showed no significant difference. The total oral health impact profile-14 scores after treatment for all participants, regardless of prosthodontic design, were significantly lower (more satisfied). The overall oral health impact profile-20E score at baseline was significantly higher (more satisfied) compared with pre-treatment conventional maxillary dentures. No significant changes were observed in the first or second years compared with baseline results. Twenty-two participants (84.6%) preferred reduced palatal coverage, regardless of prosthodontic design, after 1 year. Twenty participants (76.9%) still preferred reduced palatal coverage at the end of the second year. The provision of maxillary 3-implant overdentures to oppose mandibular 2-implant overdentures significantly improve levels of patient

  10. Depth of valve implantation, conduction disturbances and pacemaker implantation with CoreValve and CoreValve Accutrak system for Transcatheter Aortic Valve Implantation, a multi-center study.

    Science.gov (United States)

    Lenders, Guy D; Collas, Valérie; Hernandez, José Maria; Legrand, Victor; Danenberg, Haim D; den Heijer, Peter; Rodrigus, Inez E; Paelinck, Bernard P; Vrints, Christiaan J; Bosmans, Johan M

    2014-10-20

    Transcatheter Aortic Valve Implantation (TAVI) is now considered an indispensable treatment strategy in high operative risk patients with severe, symptomatic aortic stenosis. However, conduction disturbances and the need for Permanent Pacemaker (PPM) implantation after TAVI with the CoreValve prosthesis still remain frequent. We aimed to evaluate the implantation depth, the incidence and predictors of new conduction disturbances, and the need for PPM implantation within the first month after TAVI, using the new Accutrak CoreValve delivery system (ACV), compared to the previous generation CoreValve (non-ACV). In 5 experienced TAVI-centers, a total of 120 consecutive non-ACV and 112 consecutive ACV patients were included (n=232). The mean depth of valve implantation (DVI) was 8.4±4.0 mm in the non-ACV group and 7.1±4.0 mm in the ACV group (p=0.034). The combined incidence of new PPM implantation and new LBBB was 71.2% in the non-ACV group compared to 50.5% in the ACV group (p=0.014). DVI (p=0.002), first degree AV block (p=0.018) and RBBB (p<0.001) were independent predictors of PPM implantation. DVI (p<0.001) and pre-existing first degree AV-block (p=0.021) were identified as significant predictors of new LBBB. DVI is an independent predictor of TAVI-related conduction disturbances and can be reduced by using the newer CoreValve Accutrak delivery system, resulting in a significantly lower incidence of new LBBB and new PPM implantation. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  11. Impact of Different Surgeons on Dental Implant Failure.

    Science.gov (United States)

    Chrcanovic, Bruno Ramos; Kisch, Jenö; Albrektsson, Tomas; Wennerberg, Ann

    To assess the influence of several factors on the prevalence of dental implant failure, with special consideration of the placement of implants by different dental surgeons. This retrospective study is based on 2,670 patients who received 10,096 implants at one specialist clinic. Only the data of patients and implants treated by surgeons who had inserted a minimum of 200 implants at the clinic were included. Kaplan-Meier curves were stratified with respect to the individual surgeon. A generalized estimating equation (GEE) method was used to account for the fact that repeated observations (several implants) were placed in a single patient. The factors bone quantity, bone quality, implant location, implant surface, and implant system were analyzed with descriptive statistics separately for each individual surgeon. A total of 10 surgeons were eligible. The differences between the survival curves of each individual were statistically significant. The multivariate GEE model showed the following variables to be statistically significant: surgeon, bruxism, intake of antidepressants, location, implant length, and implant system. The surgeon with the highest absolute number of failures was also the one who inserted the most implants in sites of poor bone and used turned implants in most cases, whereas the surgeon with the lowest absolute number of failures used mainly modern implants. Separate survival analyses of turned and modern implants stratified for the individual surgeon showed statistically significant differences in cumulative survival. Different levels of failure incidence could be observed between the surgeons, occasionally reaching significant levels. Although a direct causal relationship could not be ascertained, the results of the present study suggest that the surgeons' technique, skills, and/or judgment may negatively influence implant survival rates.

  12. Alpine Skiing With total knee ArthroPlasty (ASWAP)

    DEFF Research Database (Denmark)

    Koesters, A.; Poetzelsberger, B.; Dela, F.

    2015-01-01

    The aim of this study was to monitor the long-term effects of skiing on health-related parameters and implant related factors like loosening and wear in patients with total knee arthroplasty. This paper describes the overall study design, general demographics, and physiological demand of the inte......The aim of this study was to monitor the long-term effects of skiing on health-related parameters and implant related factors like loosening and wear in patients with total knee arthroplasty. This paper describes the overall study design, general demographics, and physiological demand...

  13. Do preoperative antibiotics prevent dental implant complications?

    Science.gov (United States)

    Balevi, Ben

    2008-01-01

    The Cochrane Oral Health Group's Trials Registry, the Cochrane Central Register of Controlled Trials, Medline and Embase were consulted to find relevant work. Searches were made by hand of numerous journals pertinent to oral implantology. There were no language restrictions. Randomised controlled clinical trials (RCT) with a followup of at least 3 months were chosen. Outcome measures were prosthesis failures, implant failures, postoperative infections and adverse events (gastrointestinal, hypersensitivity, etc.). Two reviewers independently assessed the quality and extracted relevant data from included studies. The estimated effect of the intervention was expressed as a risk ratio together with its 95% confidence interval (CI). Numbers-needed-to-treat (NNT) were calculated from numbers of patients affected by implant failures. Meta-analysis was done only if there were studies with similar comparisons that reported the same outcome measure. Significance of any discrepancies between studies was assessed by means of the Cochran's test for heterogeneity and the I2 statistic. Only two RCT met the inclusion criteria. Meta-analysis of these two trials showed a statistically significantly higher number of patients experiencing implant failures in the group not receiving antibiotics (relative risk, 0.22; 95% CI, 0.06-0.86). The NNT to prevent one patient having an implant failure is 25 (95%CI, 13-100), based on a patient implant failure rate of 6% in people not receiving antibiotics. The following outcomes were not statistically significantly linked with implant failure: prosthesis failure, postoperative infection and adverse events (eg, gastrointestinal effects, hypersensitivity). There is some evidence suggesting that 2 g of amoxicillin given orally 1 h preoperatively significantly reduces failures of dental implants placed in ordinary conditions. It remains unclear whether postoperative antibiotics are beneficial, and which is the most effective antibiotic. One dose of

  14. Determination of migration of ion-implanted helium in silica by proton backscattering spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Szakacs, G. [KFKI Research Institute for Particle and Nuclear Physics, P.O. Box 49, H-1525 Budapest (Hungary); Szilagyi, E. [KFKI Research Institute for Particle and Nuclear Physics, P.O. Box 49, H-1525 Budapest (Hungary)], E-mail: szilagyi@rmki.kfki.hu; Paszti, F.; Kotai, E. [KFKI Research Institute for Particle and Nuclear Physics, P.O. Box 49, H-1525 Budapest (Hungary)

    2008-04-15

    Understanding the processes caused by ion implantation of light ions in dielectric materials such as silica is important for developing the diagnostic systems used in fusion and fission environments. Recently, it has been shown that ion-implanted helium is able to escape from SiO{sub 2} films. To study this process in details, helium was implanted into the central part of a buried SiO{sub 2} island up to a fluence of 4 x 10{sup 17} He/cm{sup 2}. The implanted helium could be detected in the SiO{sub 2} island, if the oxide was insulated properly from the vacuum. The shape of the helium depth distributions was far from SRIM simulation because helium distributed in the whole 1 {mu}m thick oxide layer. After the ion implantation, helium was observed only on the implanted spot. After nine months the implanted helium filled out the whole oxide island as it was expected from the high diffusivity.

  15. Determination of migration of ion-implanted helium in silica by proton backscattering spectrometry

    International Nuclear Information System (INIS)

    Szakacs, G.; Szilagyi, E.; Paszti, F.; Kotai, E.

    2008-01-01

    Understanding the processes caused by ion implantation of light ions in dielectric materials such as silica is important for developing the diagnostic systems used in fusion and fission environments. Recently, it has been shown that ion-implanted helium is able to escape from SiO 2 films. To study this process in details, helium was implanted into the central part of a buried SiO 2 island up to a fluence of 4 x 10 17 He/cm 2 . The implanted helium could be detected in the SiO 2 island, if the oxide was insulated properly from the vacuum. The shape of the helium depth distributions was far from SRIM simulation because helium distributed in the whole 1 μm thick oxide layer. After the ion implantation, helium was observed only on the implanted spot. After nine months the implanted helium filled out the whole oxide island as it was expected from the high diffusivity

  16. Phrenic paralysis during cardiac electronic device implantation: incidence, causes and clinical course.

    Science.gov (United States)

    López-Gil, María; Fontenla, Adolfo; Juliá, Justo; Parra, Juan José; Arribas, Fernando

    2016-10-01

    Phrenic paralysis is a known complication of central venous catheterization, but it is not listed as a complication related to cardiac implantable electronic device (CIED) implants. The aim of this study is to describe the incidence, causes, clinical picture, and management of phrenic paralysis occurring in this scenario. We retrospectively analysed data from our CIED implantation database and identified those patients who suffered phrenic paralysis during the implantation procedure. Four of 891 patients (subclavian puncture in 626) developed phrenic paralysis during pacemaker or defibrillator implant procedures. Severe respiratory failure needing ventilatory support occurred in two, being the phrenic paralysis transient in all of the cases. Transient phrenic paralysis may occur during CIED implantation probably related to the infiltration of local anaesthesia in the subclavian area. Mechanism, prevention, and management are discussed. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions please email: journals.permissions@oup.com.

  17. Cochlear Implants and Psychiatric Assessments: a Norrie Disease Case Report.

    Science.gov (United States)

    Jacques, Denis; Dubois, Thomas; Zdanowicz, Nicolas; Gilain, Chantal; Garin, Pierre

    2017-09-01

    It is important to perform psychiatric assessments of adult patients who are candidates for cochlear implants both to screen them for psychiatric disorders and to assess their understanding and compliance with the procedure. Deafness is a factor of difficulty for conducting in-depth psychiatric interviews, but concomitant blindness may make it impossible. After a description of Norrie disease, a rare disease in which blindness and deafness may occur together, we propose a case report of a patient suffering from the disease and who consulted in view of a cochlear implant. Early information on cochlear implants appears to be necessary before total deafness occurs in patients suffering from Norrie disease. An inventory of digital communication tools that can be used by the patient is also highly valuable. Research should be supported for a more systematic use of psychiatric assessments prior to cochlear implants. In the special case of Norrie disease, we recommend early screening for mental retardation and related psychotic disorders and, depending on the patient's level of understanding, preventive information on the benefits and limits of cochlear implants before total deafness occurs.

  18. 2D FEA of evaluation of micromovements and stresses at bone-implant interface in immediately loaded tapered implants in the posterior maxilla

    Directory of Open Access Journals (Sweden)

    Shrikar R Desai

    2013-01-01

    Full Text Available Aim: The aim of the study is to evaluate the influence implant length on stress distribution at bone implant interface in single immediately loaded implants when placed in D4 bone quality. Materials and Methods: A 2-dimensional finite element models were developed to simulate two types of implant designs, standard 3.75 mm-diameter tapered body implants of 6 and 10 mm lengths. The implants were placed in D4 bone quality with a cortical bone thickness of 0.5 mm. The implant design incorporated microthreads at the crestal part and the rest of the implant body incorporated Acme threads. The Acme thread form has a 29° thread angle with a thread height half of the pitch; the apex and valley are flat. A 100 N of force was applied vertically and in the oblique direction (at an angle of 45° to the long axis of the implants. The respective material properties were assigned. Micro-movements and stresses at the bone implant interface were evaluated. Results: The results of total deformation (micro-movement and Von mises stress were found to be lower for tapered long implant (10 mm than short implant (6 mm while using both vertical as well as oblique loading. Conclusion: Short implants can be successfully placed in poor bone quality under immediate loading protocol. The novel approach of the combination of microthreads at the crestal portion and acme threads for body portion of implant fixture gave promising results.

  19. 2D FEA of evaluation of micromovements and stresses at bone-implant interface in immediately loaded tapered implants in the posterior maxilla.

    Science.gov (United States)

    Desai, Shrikar R; Singh, Rika; Karthikeyan, I

    2013-09-01

    The aim of the study is to evaluate the influence implant length on stress distribution at bone implant interface in single immediately loaded implants when placed in D4 bone quality. A 2-dimensional finite element models were developed to simulate two types of implant designs, standard 3.75 mm-diameter tapered body implants of 6 and 10 mm lengths. The implants were placed in D4 bone quality with a cortical bone thickness of 0.5 mm. The implant design incorporated microthreads at the crestal part and the rest of the implant body incorporated Acme threads. The Acme thread form has a 29° thread angle with a thread height half of the pitch; the apex and valley are flat. A 100 N of force was applied vertically and in the oblique direction (at an angle of 45°) to the long axis of the implants. The respective material properties were assigned. Micro-movements and stresses at the bone implant interface were evaluated. The results of total deformation (micro-movement) and Von mises stress were found to be lower for tapered long implant (10 mm) than short implant (6 mm) while using both vertical as well as oblique loading. Short implants can be successfully placed in poor bone quality under immediate loading protocol. The novel approach of the combination of microthreads at the crestal portion and acme threads for body portion of implant fixture gave promising results.

  20. Anesthesia management for MitraClip device implantation

    Directory of Open Access Journals (Sweden)

    Harikrishnan Kothandan

    2014-01-01

    Full Text Available Aims and Objectives: Percutaneous MitraClip implantation has been demonstrated as an alternative procedure in high-risk patients with symptomatic severe mitral regurgitation (MR who are not suitable (or denied mitral valve repair/replacement due to excessive co morbidity. The MitraClip implantation was performed under general anesthesia and with 3-dimensional transesophageal echocardiography (TEE and fluoroscopic guidance. Materials and Methods: Peri-operative patient data were extracted from the electronic and paper medical records of 21 patients who underwent MitraClip implantations. Results: Four MitraClip implantation were performed in the catheterization laboratory; remaining 17 were performed in the hybrid operating theatre. In 2 patients, procedure was aborted, in one due to migration of the Chiari network into the left atrium and in second one, the leaflets and chords of the mitral valve torn during clipping resulting in consideration for open surgery. In the remaining 19 patients, MitraClip was implanted and the patients showed acute reduction of severe MR to mild-moderate MR. All the patients had invasive blood pressure monitoring and the initial six patients had central venous catheterization prior to the procedure. Intravenous heparin was administered after the guiding catheter was introduced through the inter-atrial septum and activated clotting time was maintained beyond 250 s throughout the procedure. Protamine was administered at the end of the procedure. All the patients were monitored in the intensive care unit after the procedure. Conclusions: Percutaneous MitraClip implantation is a feasible alternative in high-risk patients with symptomatic severe MR. Anesthesia management requirements are similar to open surgical mitral valve repair or replacement. TEE plays a vital role during the MitraClip implantation.

  1. A fully implantable rodent neural stimulator

    Science.gov (United States)

    Perry, D. W. J.; Grayden, D. B.; Shepherd, R. K.; Fallon, J. B.

    2012-02-01

    The ability to electrically stimulate neural and other excitable tissues in behaving experimental animals is invaluable for both the development of neural prostheses and basic neurological research. We developed a fully implantable neural stimulator that is able to deliver two channels of intra-cochlear electrical stimulation in the rat. It is powered via a novel omni-directional inductive link and includes an on-board microcontroller with integrated radio link, programmable current sources and switching circuitry to generate charge-balanced biphasic stimulation. We tested the implant in vivo and were able to elicit both neural and behavioural responses. The implants continued to function for up to five months in vivo. While targeted to cochlear stimulation, with appropriate electrode arrays the stimulator is well suited to stimulating other neurons within the peripheral or central nervous systems. Moreover, it includes significant on-board data acquisition and processing capabilities, which could potentially make it a useful platform for telemetry applications, where there is a need to chronically monitor physiological variables in unrestrained animals.

  2. Effect of antibiotics on implant failure and postoperative infection.

    Science.gov (United States)

    Bafail, Arwa S; Alamri, Ahmed M; Spivakovsky, Silvia

    2014-06-01

    Medline and hand search of the British Journal of Oral and Maxillofacial Surgery, Clinical Implant Dentistry and Related Research, Clinical Oral Investigations, Clinical Oral Implants Research, European Journal of Oral Implantology, Implant Dentistry, International Journal of Oral and Maxillofacial Implants, International Journal of Oral and Maxillofacial Surgery, Journal of Clinical Periodontology, Journal of Oral Implantology, Journal of Oral and Maxillofacial Surgery, Journal of Periodontology Medicina Oral, Patologa Oral y Cirugía Bucal, and Oral Surgery, Oral Medicine, Oral Pathology, Oral Radiology and Endodontology. Search of the literature was made to identify randomised controlled trials (RCTs) on the efficacy of antibiotics compared with a control group (not receiving antibiotics or receiving placebo. All articles selected from the electronic and manual searches were independently assessed by the first and second authors of this study, in accordance with the established inclusion criteria. Two reviewers independently and in duplicate evaluated the quality of the included RCTs as part of the data extraction process. Four RCTs were included in the final review. These four RCTs grouped a total of 2063 implants and a total of 1002 patients. Antibiotic use significantly lowered the implant failure rate (P = 0.003), with an odds ratio of 0.331, implying that antibiotic treatment reduced the odds of failure by 66.9%. The number needed to treat (NNT) to prevent one patient from having an implant failure was 48 (95% confidence interval 31-109). In contrast, antibiotic use did not significantly reduce the incidence of postoperative infection (P = 0.754). Based on the results of this meta-analysis, and pending further research in the field, it can be concluded that there is evidence in favour of systematic antibiotic use in patients receiving dental implants, since such treatment significantly reduces implant failure. In contrast, antibiotic use does not exert a

  3. DATA ISSUES IN TOTAL FACTOR PRODUCTIVITY BENCHMARKING: A CENTRAL EUROPEAN PERSPECTIVE

    Directory of Open Access Journals (Sweden)

    Machek Ondrej

    2012-12-01

    Full Text Available Total factor productivity is a method of measuring overall productivity of businesses, industries or economies. It is an approach which is recently becoming popular among government regulatory agencies when applying the so-called performance-based regulation. This principle induces regulated companies (for instance, electricity or natural gas distributors to behave efficiently even if their industries are not exposed to competitive pressures, since they are rewarded for being more productive than other firms in the industry, and penalized in the opposite case. The aim of this article is to deal with the question what are the main data issues when comparing total factor productivity among firms or industries with focus on the Central European region, which is very heterogeneous in terms of geographic, social, economic and historic conditions. In the first part, we introduce total factor productivity and the most common methods of its measurement � Malmquist and T�rnqvist indexes. Consequently, we divide the data issues into separate categories and discuss them more in detail. The first category of issues is related to defining the set of comparable firms. Many factors, such as the degree of competition in the market, the extent of government regulation, economies of scale, firm size, geographical conditions and historic development have to be taken into consideration. The second category is associated with specifying the time period. TFP estimates should be based on long time series and the period should include the whole business cycle and be representative and exclude extraordinary events. The third group of issues is related to defining and measuring the inputs and outputs. Since a number of difficulties are associated with labor input measurement, it is often included into operating expenditures along with materials and services. The measurement of capital is even more contentious. The outputs should reflect performance

  4. Improved knee flexion following high-flexion total knee arthroplasty

    Directory of Open Access Journals (Sweden)

    Lionberger David R

    2012-06-01

    Full Text Available Abstract Background The application of new techniques and materials in total knee arthroplasty (TKA continue to be a primary focus in orthopedic surgery. The primary aim of the present study is to evaluate post TKA total range of motion (ROM among a group of patients who received a gender specific high-flexion design modification implant compared to a control group of patients who received non-gender specific implants. Methods and results The control group was comprised of 39 TKAs that were recruited pre-operatively and received the non-gender specific implant while the study group consisted of 39 TKAs who received gender specific implants. The study group yielded an improvement in mean post-operative ROM of 21° at 12 months, whereas the mean improvement in ROM among the control group was 11°. Thus, the study group had a 10° increased ROM improvement (91% over the control group (p = 0.00060. In addition, 100% of the subjects with gender specific high-flexion implants achieved greater or equal ROM post-operatively compared to 82% for the control cohort. Lastly, women who exhibited greater pre-operative ROM and lower body mass index (BMI were found to benefit the most with the gender specific prosthesis. Conclusion Our study demonstrates that among subjects with a normal BMI, the gender specific high-flexion knee implant is associated with increased ROM as compared to the non-gender specific non-high-flexion implant designs.

  5. Urinary morbidity with a modified peripheral loading technique of transperineal 125i prostate implantation

    International Nuclear Information System (INIS)

    Brown, Douglas; Colonias, Athanasios; Miller, Ralph; Benoit, Ronald; Cohen, Jeffrey; Arshoun, Youssef; Galloway, Michael; Karlovits, Stephen; Wu, Andrew; Johnson, Mark; Quinn, Annette; Kalnicki, Shalom

    2000-01-01

    Purpose: Analysis of urinary morbidity within the first 12 months following a modified peripheral loading technique for permanent transperineal transrectal ultrasound (TRUS) guided 125 I prostate implantation and comparison of urinary morbidity with various clinical and implant parameters. Materials and Methods: Between October 1, 1996, and March 11, 1998, 87 patients with favorable, early stage prostate cancer were treated with permanent transperineal TRUS guided 125 I prostate implantation. A peripheral loading technique was utilized for source placement with 75-80% source distribution in the periphery and 20-25% source distribution centrally. A mean total activity of 38 mCi of 125 I was implanted (range, 19-66 mCi). The mean source activity was 0.43 mCi/source (range, 0.26-0.61 mCi/source) and the mean number of sources implanted was 88 (range, 56-134). The minimum prescribed dose to the prostate was 145 Gy. The median D 90 , V 100 , and V 150 were 152 Gy (range, 104-211 Gy), 92% (range, 71-99%), and 61% (range, 11-89%), respectively. The median follow-up time was 19 months (range, 12-29 months). Urinary morbidity was scored at 3 weeks and then at 3-month intervals for the first 2 years using a modified Radiation Therapy Oncology Group (RTOG) grading system (scale 0-5). Results: Most patients developed at least minor urinary symptoms with frequency or nocturia being the most common. Overall, 79% (69/87) of patients experienced urinary morbidity with 21% (18/87) reporting no symptoms. The incidence of overall Grade 1 urinary morbidity was 37% (32/87); Grade 2 morbidity was 37% (32/87); and Grade 3 morbidity was 6% (5/87). There was no Grade 4 or 5 morbidity. The incidence of Grade 0 frequency/nocturia was 36% (31/87); Grade 1 was 33% (29/87); Grade 2 was 30% (26/87); and Grade 3 was 1% (1/87). Grade 0 dysuria was seen in 56% (49/87) of patients; 32% (28/87) had Grade 1; 10% (9/87) Grade 2; and 1% (1/87) Grade 3 dysuria. Most urinary symptoms started a few weeks

  6. [Pre-operation evaluation and intra-operation management of cochlear implantation].

    Science.gov (United States)

    Zhang, Dao-xing; Hu, Bao-hua; Xiao, Yu-li; Shi, Bo-ning

    2004-10-01

    To summarize pre-operation evaluation experiences in cochlear implantation. Performing auditory evaluation and image analysis seriously in 158 severe hearing loss or total deaf cases before cochlear implantation, comparing their performance with the findings during and post operation. Among the total 158 cases, 116 cases with normal structure, 42 cases with the abnormal findings of the inner or middle ear. Stapedial gusher happened in 6 cases, 1 case was not predicted before operation. Except 1 case with serious malformation, the findings of other 157 cases in operation were consistent with the pre-operation evaluation. We helped all patients reconstruct auditory conduction with cochlear implantation, and the average hearing level up to 37.6 dB SPL. Performing image analysis seriously before operation and planning for operation according to HRCT can do great help to cochlear implantation. The operation under the HRCT instruction has less complications.

  7. Immediate provisional restoration of a single-tooth implant in the esthetic zone: A case report

    Directory of Open Access Journals (Sweden)

    Po-Sung Fu

    2011-02-01

    Full Text Available Immediate implant restoration of single implants may demonstrate a positive effect on peri-implant soft tissue. Placement of a provisional restoration following implant surgery can create soft tissue contours that resemble normal gingival topography before placement of the definitive prosthesis. This article describes a staged approach of the mandibular permanent right central incisor, which was congenital missing. The proper space for restoration of the missing incisor was created through orthodontic treatment. The scheduled implant site was reconstructed using autogenous bone harvested from the chin region. After a healing period of four months, an implant was installed with the connection of a fixed provisional crown to a prefabricated temporary abutment. The soft tissue around the implant healed according to the contours of the provisional restoration and the emergence profile was used to duplicate the definitive restoration. Peri-implant esthetics was achieved through the staged approach and immediate restoration of the implant.

  8. Occupational exposure of professionals during interstitial permanent prostate brachytherapy implants

    International Nuclear Information System (INIS)

    Pirraco, R.; Pereira, A.; Viterbo, T.; Cavaco, A.

    2006-01-01

    Full text of publication follows: Introduction: In this study we present dose measurements for professionals exposed during interstitial 125 I permanent prostate brachytherapy implants. Methods and Materials: The implant technique used was intra operative real time using strand and loose seeds. The professionals inside the operating room are an oncologist, a radiologist, a physicist, a nurse and an anesthesiologist. The oncologist and the physicist contact directly the loaded needle with radioactive seeds and two types of measurements were taken: total body and extremities (finger) dose. The rest of the team operates at long distances, but measurements were made. To measure total body equivalent dose we use a Berthold Umo LB 123 coupled with a LB 1236-H10 detector, and we recorded dose, time and distance from implant location. Finger dosemeters are thermo -luminescent dosimeter (TLD) rings that were controlled over one month. Results: 50 cases (average number of applications per year) were analysed for extremities measurements and 9 cases for total body measurements (in this case, the results were extrapolated for 50 cases), with an average of 26.1 mCi total activity per implant (in a range of 17.4 - 40.3 mCi). The finger dose was 1.8 mSv for the oncologist and 1.9 mSv for the physicist. The interpolation of total body equivalent dose for the oncologist was 24 mSv, for the radiologist 6 mSv and 9 mSv for the physicist. The rest of the team did not receive anything but background radiation. The annual national limit dose for workers is 20 mSv for total body irradiation, and 500 mSv for extremities. Conclusion: In conclusion we may say that during interstitial permanent prostate brachytherapy implants, total doses received for all groups are not significant when compared to annual limits for Portuguese laws 1. Even so, our main goal is always to get the less possible dose (ALARA principle). References: 1. Decreto Lei n. 180/2002 de 8 de Agosto. (authors)

  9. Occupational exposure of professionals during interstitial permanent prostate brachytherapy implants

    Energy Technology Data Exchange (ETDEWEB)

    Pirraco, R.; Pereira, A.; Viterbo, T.; Cavaco, A. [Instituto Portugues de Oncologia Francisco Gentil, Centro R egional de Oncologia do Porto, SA, Porto (Portugal)

    2006-07-01

    Full text of publication follows: Introduction: In this study we present dose measurements for professionals exposed during interstitial 125 I permanent prostate brachytherapy implants. Methods and Materials: The implant technique used was intra operative real time using strand and loose seeds. The professionals inside the operating room are an oncologist, a radiologist, a physicist, a nurse and an anesthesiologist. The oncologist and the physicist contact directly the loaded needle with radioactive seeds and two types of measurements were taken: total body and extremities (finger) dose. The rest of the team operates at long distances, but measurements were made. To measure total body equivalent dose we use a Berthold Umo LB 123 coupled with a LB 1236-H10 detector, and we recorded dose, time and distance from implant location. Finger dosemeters are thermo -luminescent dosimeter (TLD) rings that were controlled over one month. Results: 50 cases (average number of applications per year) were analysed for extremities measurements and 9 cases for total body measurements (in this case, the results were extrapolated for 50 cases), with an average of 26.1 mCi total activity per implant (in a range of 17.4 - 40.3 mCi). The finger dose was 1.8 mSv for the oncologist and 1.9 mSv for the physicist. The interpolation of total body equivalent dose for the oncologist was 24 mSv, for the radiologist 6 mSv and 9 mSv for the physicist. The rest of the team did not receive anything but background radiation. The annual national limit dose for workers is 20 mSv for total body irradiation, and 500 mSv for extremities. Conclusion: In conclusion we may say that during interstitial permanent prostate brachytherapy implants, total doses received for all groups are not significant when compared to annual limits for Portuguese laws 1. Even so, our main goal is always to get the less possible dose (ALARA principle). References: 1. Decreto Lei n. 180/2002 de 8 de Agosto. (authors)

  10. Comparison of marginal bone loss between internal- and external-connection dental implants in posterior areas without periodontal or peri-implant disease.

    Science.gov (United States)

    Kim, Dae-Hyun; Kim, Hyun Ju; Kim, Sungtae; Koo, Ki-Tae; Kim, Tae-Il; Seol, Yang-Jo; Lee, Yong-Moo; Ku, Young; Rhyu, In-Chul

    2018-04-01

    The purpose of this retrospective study with 4-12 years of follow-up was to compare the marginal bone loss (MBL) between external-connection (EC) and internal-connection (IC) dental implants in posterior areas without periodontal or peri-implant disease on the adjacent teeth or implants. Additional factors influencing MBL were also evaluated. This retrospective study was performed using dental records and radiographic data obtained from patients who had undergone dental implant treatment in the posterior area from March 2006 to March 2007. All the implants that were included had follow-up periods of more than 4 years after loading and satisfied the implant success criteria, without any peri-implant or periodontal disease on the adjacent implants or teeth. They were divided into 2 groups: EC and IC. Subgroup comparisons were conducted according to splinting and the use of cement in the restorations. A statistical analysis was performed using the Mann-Whitney U test for comparisons between 2 groups and the Kruskal-Wallis test for comparisons among more than 2 groups. A total of 355 implants in 170 patients (206 EC and 149 IC) fulfilled the inclusion criteria and were analyzed in this study. The mean MBL was 0.47 mm and 0.15 mm in the EC and IC implants, respectively, which was a statistically significant difference ( P <0.001). Comparisons according to splinting (MBL of single implants: 0.34 mm, MBL of splinted implants: 0.31 mm, P =0.676) and cement use (MBL of cemented implants: 0.27 mm, MBL of non-cemented implants: 0.35 mm, P =0.178) showed no statistically significant differences in MBL, regardless of the implant connection type. IC implants showed a more favorable bone response regarding MBL in posterior areas without peri-implantitis or periodontal disease.

  11. Four-year Follow-up of the Changes in Anterior Segment After Phakic Collamer Lens Implantation.

    Science.gov (United States)

    Lu, Yuanyuan; Yang, Na; Li, Xuedong; Kong, Jun

    2017-06-01

    To assess the changes and relationship in central vaulting, flare intensity, and crystalline lens thickness during a follow-up period of 4 years after implantable collamer lens (ICL) implantation in eyes with high myopia. Retrospective observational study. Ninety-eight eyes of 50 patients were followed up with routine measurements of central vaulting, crystalline lens thickness, endothelial cell density, and aqueous flare postoperatively. Data were analyzed by repeated-measures analysis of variance. The relationship between the annual change in crystal lens thickness after surgery and age was evaluated by Pearson correlation coefficient and linear regression. There was a continuous reduction in central vaulting and endothelial cell density as well as an increase in crystalline lens thickness in ICL eyes from 1 month onward to 5 years postoperatively (P lens thickness (r = 0.617, P lens thickness are more prominent during the first year after ICL implantation, tending to be relatively stable afterwards. The anterior inflammation during the early postoperative period synchronizes with the sharp progression of crystalline lens changes within the first year. Copyright © 2017 Elsevier Inc. All rights reserved.

  12. Short Dental Implants Retaining Two-Implant Mandibular Overdentures in Very Old, Dependent Patients: Radiologic and Clinical Observation Up to 5 Years.

    Science.gov (United States)

    Maniewicz, Sabrina; Buser, Ramona; Duvernay, Elena; Vazquez, Lydia; Loup, Angelica; Perneger, Thomas V; Schimmel, Martin; Müller, Frauke

    To describe the survival rate and peri-implant bone loss in very old patients dependent for their activities of daily living (ADL), treated with mandibular two-implant overdentures (IODs) in the context of a previously reported randomized controlled trial. A total of 19 patients received two interforaminal Straumann implants (Regular Neck, 4.1 mm diameter, 8 mm length) that were subsequently loaded with Locator attachments, transforming their preexisting inferior conventional denture into an IOD. The primary outcome measures were implant survival rate and radiographically assessed peri-implant bone loss. Secondary outcome measures included peri-implant probing depth and Plaque Index scores, as well as implant mobility. Nutritional state (body mass index and blood markers) and cognitive state (Mini-Mental State Examination) were also analyzed. The patient cohort comprised eight men and 11 women with a mean age of 85.7 ± 6.6 years. The implant survival rate up to 5 years was 94.7%, with one early and one late implant failure. The mean loss of peri-implant bone height was 0.17 mm per year (95% confidence interval: 0.09 to 0.24; P implant probing depth and Plaque Index scores were low and stable during the first 2 years, and thereafter increased continuously. Correlation analysis suggests that a reduced cognitive function and nutritional state are not a particular risk factor for accelerated peri-implant bone loss. The high implant survival and acceptable peri-implant health suggest that neither age nor dependency for the ADLs is a contraindication for the placement of implants. Nevertheless, close monitoring of the patients concerning a potential further functional decline precluding denture management and performing oral hygiene measures is advised.

  13. Influence of Statins locally applied from orthopedic implants on osseous integration

    Directory of Open Access Journals (Sweden)

    Pauly Stephan

    2012-10-01

    Full Text Available Abstract Background Simvastatin increases the expression of bone morphogenetic protein 2 (BMP-2 in osteoblasts, therefore it is important to investigate the influence of statins on bone formation, fracture healing and implant integration. The aim of the present study was to investigate the effect of Simvastatin, locally applied from intramedullary coated and bioactive implants, on bone integration using biomechanical and histomorphometrical analyses. Methods Eighty rats received retrograde nailing of the femur with titanium implants: uncoated vs. polymer-only (poly(D,L-lactide vs. polymer plus drug coated (either Simvastatin low- or high dosed; “SIM low/ high”. Femurs were harvested after 56 days for radiographic and histomorphometric or biomechanical analysis (push-out. Results Radiographic analysis revealed no pathological findings for animals of the control and SIM low dose group. However, n=2/10 animals of the SIM high group showed osteolysis next to the implant without evidence of bacterial infection determined by microbiological analysis. Biomechanical results showed a significant decrease in fixation strength for SIM high coated implants vs. the control groups (uncoated and PDLLA. Histomorphometry revealed a significantly reduced total as well as direct bone/implant contact for SIM high- implants vs. controls (uncoated and PDLLA-groups. Total contact was reduced for SIM low vs. uncoated controls. Significantly reduced new bone formation was measured around SIM high coated implants vs. both control groups. Conclusions This animal study suggests impaired implant integration with local application of Simvastatin from intramedullary titanium implants after 8 weeks when compared to uncoated or carrier-only coated controls.

  14. Comparison of the artifacts caused by metallic implants in breast MRI using dual-echo dixon versus conventional fat-suppression techniques.

    Science.gov (United States)

    Le, Yuan; Kipfer, Hal D; Majidi, Shadie S; Holz, Stephanie; Lin, Chen

    2014-09-01

    The purpose of this article is to evaluate and compare the artifacts caused by metal implants in breast MR images acquired with dual-echo Dixon and two conventional fat-suppression techniques. Two types of biopsy markers were embedded into a uniform fat-water emulsion. T1-weighted gradient-echo images were acquired on a clinical 3-T MRI scanner with three different fat-suppression techniques-conventional or quick fat saturation, spectrally selective adiabatic inversion recovery (SPAIR), and dual-echo Dixon-and the 3D volumes of artifacts were measured. Among the subjects of a clinical breast MRI study using the same scanner, five patients were found to have one or more metal implants. The artifacts in Dixon and SPAIR fat-suppressed images were evaluated by three radiologists, and the results were compared with those of the phantom study. In the phantom study, the artifacts appeared as interleaved bright and dark rings on SPAIR and quick-fat-saturation images, whereas they appeared as dark regions with a thin bright rim on Dixon images. The artifacts imaged with the Dixon technique had the smallest total volume. However, the reviewers found larger artifact diameters on patient images using the Dixon sequence because only the central region was recognized as an artifact on the SPAIR images. Metal implants introduce artifacts of different types and sizes, according to the different fat-suppression techniques used. The dual-echo Dixon technique produces a larger central void, allowing the implant to be easily identified, but presents a smaller overall artifact volume by obscuring less area in the image, according to a quantitative phantom study.

  15. Ion implantation

    International Nuclear Information System (INIS)

    Dearnaley, Geoffrey

    1975-01-01

    First, ion implantation in semiconductors is discussed: ion penetration, annealing of damage, gettering, ion implanted semiconductor devices, equipement requirements for ion implantation. The importance of channeling for ion implantation is studied. Then, some applications of ion implantation in metals are presented: study of the corrosion of metals and alloys; influence or ion implantation on the surface-friction and wear properties of metals; hyperfine interactions in implanted metals

  16. NOTE: Optimal needle arrangement for intraoperative planning in permanent I-125 prostate implants

    Science.gov (United States)

    Thompson, S. A.; Fung, A. Y. C.; Zaider, M.

    2002-08-01

    One limitation of intraoperative planning of permanent prostate implants is that needles must already be in the gland before planning images are acquired. Improperly placed needles often restrict the capability of generating optimal seed placement. We developed guiding principles for the proper layout of needles within the treatment volume. The Memorial Sloan-Kettering Cancer Center planning system employs a genetic algorithm to find the optimal seed implantation pattern consistent with pre-assigned constraints (needle geometry, uniformity, conformity and the avoidance of high doses to urethra and rectum). Ultrasound volumes for twelve patients with I-125 implants were used to generate six plans per patient (total 72 plans) with different needle arrangements. The plans were evaluated in terms of V100 (percentage prostate volume receiving at least the prescription dose), U135 (percentage urethra volume receiving at least 135% of prescription dose), and CI (conformity index, the ratio of treatment volume to prescription dose volume.) The method termed POSTCTR, in which needles were placed on the periphery of the largest ultrasound slice and posterior central needles were placed as needed, consistently gave superior results for all prostate sizes. Another arrangement, labelled POSTLAT, where the needles were placed peripherally with additional needles in the posterior lateral lobes, also gave satisfactory results. We advocate two needle arrangements, POSTCTR and POSTLAT, with the former giving better results.

  17. Hearing Preservation after Cochlear Implantation: UNICAMP Outcomes

    Directory of Open Access Journals (Sweden)

    Guilherme Machado de Carvalho

    2013-01-01

    Full Text Available Background. Electric-acoustic stimulation (EAS is an excellent choice for people with residual hearing in low frequencies but not high frequencies and who derive insufficient benefit from hearing aids. For EAS to be effective, subjects' residual hearing must be preserved during cochlear implant (CI surgery. Methods. We implanted 6 subjects with a CI. We used a special surgical technique and an electrode designed to be atraumatic. Subjects' rates of residual hearing preservation were measured 3 times postoperatively, lastly after at least a year of implant experience. Subjects' aided speech perception was tested pre- and postoperatively with a sentence test in quiet. Subjects' subjective responses assessed after a year of EAS or CI experience. Results. 4 subjects had total or partial residual hearing preservation; 2 subjects had total residual hearing loss. All subjects' hearing and speech perception benefited from cochlear implantation. CI diminished or eliminated tinnitus in all 4 subjects who had it preoperatively. 5 subjects reported great satisfaction with their new device. Conclusions. When we have more experience with our surgical technique we are confident we will be able to report increased rates of residual hearing preservation. Hopefully, our study will raise the profile of EAS in Brazil and Latin/South America.

  18. Vibroacoustography for the assessment of total hip arthroplasty

    Directory of Open Access Journals (Sweden)

    Hermes A.S. Kamimura

    2013-04-01

    Full Text Available OBJECTIVES: This paper proposes imaging with 3-dimensional vibroacoustography for postoperatively assessing the uncovered cup area after total hip arthroplasty as a quantitative criterion to evaluate implant fixation. METHODS: A phantom with a bone-like structure covered by a tissue-mimicking material was used to simulate a total hip arthroplasty case. Vibroacoustography images of the uncovered cup region were generated using a two-element confocal ultrasound transducer and a hydrophone inside a water tank. Topological correction based on the geometry of the implant was performed to generate a 3-dimensional representation of the vibroacoustography image and to accurately evaluate the surface. The 3-dimensional area obtained by the vibroacoustography approach was compared to the area evaluated by a 3-dimensional motion capture system. RESULTS: The vibroacoustography technique provided high-resolution, high-contrast, and speckle-free images with less sensitivity to the beam incidence. Using a 3-dimensional-topology correction of the image, we accurately estimated the uncovered area of the implant with a relative error of 8.1% in comparison with the motion capture system measurements. CONCLUSION: Measurement of the cup coverage after total hip arthroplasty has not been well established; however, the covered surface area of the acetabular component is one of the most important prognostic factors. The preliminary results of this study show that vibroacoustography is a 3-dimensional approach that can be used to postoperatively evaluate total hip arthroplasty. The favorable results also provide an impetus for exploring vibroacoustography in other bone or implant surface imaging applications.

  19. Low permanent pacemaker rates following Lotus device implantation for transcatheter aortic valve replacement due to modified implantation protocol.

    Science.gov (United States)

    Krackhardt, Florian; Kherad, Behrouz; Krisper, Maximilian; Pieske, Burkert; Laule, Michael; Tschöpe, Carsten

    2017-01-01

    Conduction disturbances requiring permanent pacemaker implantation following transcatheter aortic valve replacement (TAVR) are a common problem. Pacemaker implantation rates after TAVR appear to be higher compared to conventional aortic valve replacement. The aim of this study was to analyze whether a high annulus implantation conveys the benefit of a decreased rate of permanent pacemaker implantation while being safe and successful according to Valve Academic Research Consortium 2 (VARC2)-criteria. A total of 23 patients with symptomatic severe aortic valve stenosis, an aortic annulus of 19-27 mm and at high risk for surgery were treated with the Lotus valve. In all patients the valve was implanted in a high annulus position via femoral access. The primary device performance endpoint was VARC2-defined device success after 30 days and the primary safety endpoint was the need for permanent pacemaker implantation. The mean age was 73.23 ± 7.65 years, 46% were female, 38% were New York Heart Association class III/IV at baseline. Thirty-day follow-up data were available for all patients. The VARC2-defined device success rate after 30 days was 22/23 (96%). 2/21 (10%) patients required a newly implanted pacemaker due to 3rd degree atrioventricular block. 25% of the patients developed a new left bundle branch block after valvuloplasty or device implantation. 21 of the 23 patients (96%) had no other signs of conduction disturbances after 30 days. The approach of the modified implantation technique of Lotus TAVR device was safe and effective. The incidence of need for a permanent pacemaker following TAVR could be significantly reduced due to adopted implantation protocol.

  20. Bone Response to Two Dental Implants with Different Sandblasted/Acid-Etched Implant Surfaces: A Histological and Histomorphometrical Study in Rabbits

    Directory of Open Access Journals (Sweden)

    Antonio Scarano

    2017-01-01

    Full Text Available Background. Scientific evidence in the field of implant dentistry of the past 20 years established that titanium rough surfaces have shown improved osseointegration rates. In a majority of dental implants, the surface microroughness was obtained by grit blasting and/or acid etching. The aim of the study was to evaluate in vivo two different highly hydrophilic surfaces at different experimental times. Methods. Calcium-modified (CA and SLActive surfaces were evaluated and a total of 18 implants for each type of surface were positioned into the rabbit articular femoral knee-joint in a split model experiment, and they were evaluated histologically and histomorphometrically at 15, 30, and 60 days of healing. Results. Bone-implant contact (BIC at the two-implant surfaces was significantly different in favor of the CA surface at 15 days (p=0.027, while SLActive displayed not significantly higher values at 30 (p=0.51 and 60 days (p=0.061. Conclusion. Both implant surfaces show an intimate interaction with newly formed bone.

  1. Modulating macrophage polarization with divalent cations in nanostructured titanium implant surfaces

    International Nuclear Information System (INIS)

    Lee, Chung-Ho; Kim, Youn-Jeong; Jang, Je-Hee; Park, Jin-Woo

    2016-01-01

    Nanoscale topographical modification and surface chemistry alteration using bioactive ions are centrally important processes in the current design of the surface of titanium (Ti) bone implants with enhanced bone healing capacity. Macrophages play a central role in the early tissue healing stage and their activity in response to the implant surface is known to affect the subsequent healing outcome. Thus, the positive modulation of macrophage phenotype polarization (i.e. towards the regenerative M2 rather than the inflammatory M1 phenotype) with a modified surface is essential for the osteogenesis funtion of Ti bone implants. However, relatively few advances have been made in terms of modulating the macrophage-centered early healing capacity in the surface design of Ti bone implants for the two important surface properties of nanotopography and and bioactive ion chemistry. We investigated whether surface bioactive ion modification exerts a definite beneficial effect on inducing regenerative M2 macrophage polarization when combined with the surface nanotopography of Ti. Our results indicate that nanoscale topographical modification and surface bioactive ion chemistry can positively modulate the macrophage phenotype in a Ti implant surface. To the best of our knowledge, this is the first demonstration that chemical surface modification using divalent cations (Ca and Sr) dramatically induces the regenerative M2 macrophage phenotype of J774.A1 cells in nanostructured Ti surfaces. In this study, divalent cation chemistry regulated the cell shape of adherent macrophages and markedly up-regulated M2 macrophage phenotype expression when combined with the nanostructured Ti surface. These results provide insight into the surface engineering of future Ti bone implants that are harmonized between the macrophage-governed early wound healing process and subsequent mesenchymal stem cell-centered osteogenesis function. (paper)

  2. Modulating macrophage polarization with divalent cations in nanostructured titanium implant surfaces

    Science.gov (United States)

    Lee, Chung-Ho; Kim, Youn-Jeong; Jang, Je-Hee; Park, Jin-Woo

    2016-02-01

    Nanoscale topographical modification and surface chemistry alteration using bioactive ions are centrally important processes in the current design of the surface of titanium (Ti) bone implants with enhanced bone healing capacity. Macrophages play a central role in the early tissue healing stage and their activity in response to the implant surface is known to affect the subsequent healing outcome. Thus, the positive modulation of macrophage phenotype polarization (i.e. towards the regenerative M2 rather than the inflammatory M1 phenotype) with a modified surface is essential for the osteogenesis funtion of Ti bone implants. However, relatively few advances have been made in terms of modulating the macrophage-centered early healing capacity in the surface design of Ti bone implants for the two important surface properties of nanotopography and and bioactive ion chemistry. We investigated whether surface bioactive ion modification exerts a definite beneficial effect on inducing regenerative M2 macrophage polarization when combined with the surface nanotopography of Ti. Our results indicate that nanoscale topographical modification and surface bioactive ion chemistry can positively modulate the macrophage phenotype in a Ti implant surface. To the best of our knowledge, this is the first demonstration that chemical surface modification using divalent cations (Ca and Sr) dramatically induces the regenerative M2 macrophage phenotype of J774.A1 cells in nanostructured Ti surfaces. In this study, divalent cation chemistry regulated the cell shape of adherent macrophages and markedly up-regulated M2 macrophage phenotype expression when combined with the nanostructured Ti surface. These results provide insight into the surface engineering of future Ti bone implants that are harmonized between the macrophage-governed early wound healing process and subsequent mesenchymal stem cell-centered osteogenesis function.

  3. Dual-modal photoacoustic and ultrasound imaging of dental implants

    Science.gov (United States)

    Lee, Donghyun; Park, Sungjo; Kim, Chulhong

    2018-02-01

    Dental implants are common method to replace decayed or broken tooth. As the implant treatment procedures varies according to the patients' jawbone, bone ridge, and sinus structure, appropriate examinations are necessary for successful treatment. Currently, radiographic examinations including periapical radiology, panoramic X-ray, and computed tomography are commonly used for diagnosing and monitoring. However, these radiographic examinations have limitations in that patients and operators are exposed to radioactivity and multiple examinations are performed during the treatment. In this study, we demonstrated photoacoustic (PA) and ultrasound (US) combined imaging of dental implant that can lower the total amount of absorbed radiation dose in dental implant treatment. An acoustic resolution PA macroscopy and a clinical PA/US system was used for dental implant imaging. The acquired dual modal PA/US imaging results support that the proposed photoacoustic imaging strategy can reduce the radiation dose rate during dental implant treatment.

  4. Bruxism and Dental Implants: A Meta-Analysis.

    Science.gov (United States)

    Chrcanovic, Bruno Ramos; Albrektsson, Tomas; Wennerberg, Ann

    2015-10-01

    To test the null hypothesis of no difference in the implant failure rates, postoperative infection, and marginal bone loss after the insertion of dental implants in bruxers compared with the insertion in non-bruxers against the alternative hypothesis of a difference. An electronic search was undertaken in June 2014. Eligibility criteria included clinical studies, either randomized or not. Ten publications were included with a total of 760 implants inserted in bruxers (49 failures; 6.45%) and 2989 in non-bruxers (109 failures; 3.65%). Due to lack of information, meta-analyses for the outcomes "postoperative infection" and "marginal bone loss" were not possible. A risk ratio of 2.93 was found (95% confidence interval, 1.48-5.81; P = 0.002). These results cannot suggest that the insertion of dental implants in bruxers affects the implant failure rates due to a limited number of published studies, all characterized by a low level of specificity, and most of them deal with a limited number of cases without a control group. Therefore, the real effect of bruxing habits on the osseointegration and survival of endosteal dental implants is still not well established.

  5. Implantation of total body irradiation in radiotherapy

    International Nuclear Information System (INIS)

    Habitzreuter, Angela Beatriz

    2010-01-01

    Before implementing a treatment technique, the characteristics of the beam under irradiation conditions must be well acknowledged and studied. Each one of the parameters used to calculate the dose has to be measured and validated before its utilization in clinical practice. This is particularly necessary when dealing with special techniques. In this work, all necessary parameters and measurements are described for the total body irradiation implementation in facilities designed for conventional treatments that make use of unconventional geometries to generate desired enlarged field sizes. Furthermore, this work presents commissioning data of this modality at Hospital das Clinicas of Sao Paulo using comparison of three detectors types for measurements of entrance dose during total body irradiation treatment. (author)

  6. Perioperative blood saving measures in total hip and knee arthroplasty

    NARCIS (Netherlands)

    Horstmann, W.G.

    2011-01-01

    This dissertation explores and discusses different aspects of blood loss and blood-saving measures in total hip and knee arthroplasty. Background: Worldwide, approximately 1 million total hip and 1 million total knee prostheses are implanted each year. Total hip arthroplasty and total

  7. Esthetic Evaluation of Implant Crowns and Peri-Implant Soft Tissue in the Anterior Maxilla: Comparison and Reproducibility of Three Different Indices.

    Science.gov (United States)

    Tettamanti, Sandro; Millen, Christopher; Gavric, Jelena; Buser, Daniel; Belser, Urs C; Brägger, Urs; Wittneben, Julia-Gabriela

    2016-06-01

    A successful implant reconstruction with optimal esthetics consists of a visually pleasing prosthesis and complete and healthy surrounding soft tissue. In the current literature, numerous indices used to qualitatively assess esthetics have been described. However, studies comparing the indices and their reproducibility are scarce. The aim of this study was to compare three different esthetic indices for the evaluation of single implant-supported crowns. A total of 10 prosthodontists (P), 10 orthodontists (O), 10 general dentists (G), and 10 lay people (L) independently performed the same assessment using 30 photographs and corresponding casts with three different esthetic indices (Peri-Implant and Crown Index [PICI], Implant Crown Aesthetic Index [ICAI], "Pink Esthetic Score/White Esthetic Score [PES/WES]) and repeated the evaluations 4 weeks later. The PES/WES and the PICI showed significantly higher esthetic scores (pink, white, total) and clinical acceptance compared with the ICAI in all four groups and in both assessments. The highest intraobserver agreement was achieved using the PES/WES and the least with the ICAI. The mean Kappa per group ranged from 0.18 (group L with ICAI) to 0.63 (group G with PICI). In comparison with the ICAI, the PES/WES and PICI were more reproducible. Therefore, PES/WES and PICI seem to be more suitable as esthetic indices for single implant crowns. © 2015 Wiley Periodicals, Inc.

  8. Short Term Evaluation of an Anatomically Shaped Polycarbonate Urethane Total Meniscus Replacement in a Goat Model.

    Directory of Open Access Journals (Sweden)

    A C T Vrancken

    Full Text Available Since the treatment options for symptomatic total meniscectomy patients are still limited, an anatomically shaped, polycarbonate urethane (PCU, total meniscus replacement was developed. This study evaluates the in vivo performance of the implant in a goat model, with a specific focus on the implant location in the joint, geometrical integrity of the implant and the effect of the implant on synovial membrane and articular cartilage histopathological condition.The right medial meniscus of seven Saanen goats was replaced by the implant. Sham surgery (transection of the MCL, arthrotomy and MCL suturing was performed in six animals. The contralateral knee joints of both groups served as control groups. After three months follow-up the following aspects of implant performance were evaluated: implant position, implant deformation and the histopathological condition of the synovium and cartilage.Implant geometry was well maintained during the three month implantation period. No signs of PCU wear were found and the implant did not induce an inflammatory response in the knee joint. In all animals, implant fixation was compromised due to suture breakage, wear or elongation, likely causing the increase in extrusion observed in the implant group. Both the femoral cartilage and tibial cartilage in direct contact with the implant showed increased damage compared to the sham and sham-control groups.This study demonstrates that the novel, anatomically shaped PCU total meniscal replacement is biocompatible and resistant to three months of physiological loading. Failure of the fixation sutures may have increased implant mobility, which probably induced implant extrusion and potentially stimulated cartilage degeneration. Evidently, redesigning the fixation method is necessary. Future animal studies should evaluate the improved fixation method and compare implant performance to current treatment standards, such as allografts.

  9. Low implant migration of the SIGMA® medial unicompartmental knee arthroplasty

    DEFF Research Database (Denmark)

    Koppens, Daan; Stilling, Maiken; Munk, Stig

    2017-01-01

    The purpose of this study was to evaluate implant migration of the fixed-bearing Sigma® medial unicompartmental knee arthroplasty (UKA). UKA is a regularly used treatment for patients with medial osteoarthritis (OA) of the knee. UKA has a higher revision rate than total knee arthroplasty. Implant...

  10. Avaliação de um novo implante intra-orbitário: resultados preliminares Evaluation of a new intraorbital implant: preliminary results

    Directory of Open Access Journals (Sweden)

    Thierry Malet

    2003-01-01

    Full Text Available OBJETIVO: Apresentar novo tipo de implante orbitário, com formato original, o modo de utilização e os resultados clínicos preliminares. MÉTODOS: Os autores descrevem a técnica cirúrgica utilizada para a inserção do novo implante em 22 pacientes, como implante primário ou secundário. Os pacientes foram avaliados de forma prospectiva quanto aos seguintes aspectos: cosmético (grau de sulco suprapalpebral e enoftalmia, mobilidade, centragem e volume do implante. O tempo de seguimento variou de 3 a 15 meses (média 1 ano. RESULTADOS: Observou-se resultado cosmético satisfatório, sem casos de enoftalmia ou de sulco suprapalpebral importante, bem como boa mobilidade das próteses adaptadas sobre o novo implante. Não houve casos de infecção, migração ou extrusão do implante. CONCLUSÃO: Os resultados pós-operatórios com o novo implante são comparáveis aos implantes com pinos externos. Contudo um estudo multicêntrico, com maior tempo de controle pós-operatório é necessário, para avaliação mais acurada das complicações potenciais.PURPOSE: To describe a new orbital implant, with an original shape, the surgical technique adapted for its implantation and preliminary results. METHODS: The authors describe the surgical technique performed in 22 patients, either as primary or secondary implants. The patients were evaluated in a prospective way to cosmesis (degree of upper lid sulcus and enophthalmos, implant mobility, volume and centralization. Follow-up ranged from 3 to 15 months (average 1 year. RESULTS: A good cosmetic result without cases of severe upper lid sulcus or enophthalmos and a good prosthesis mobility were observed. There was no implant infection, migration or extrusion. CONCLUSIONS: We conclude that the clinical results with the new implant can be compared to the usual coupled ones, but a multicentric study, with longer follow-up is necessary, for a better evaluation of its potential complications.

  11. RAPD analysis of alfalfa DNA mutation via N+ implantation

    International Nuclear Information System (INIS)

    Li Yufeng; Huang Qunce; Yu Zengliang; Liang Yunzhang

    2003-01-01

    Germination capacity of alfalfa seeds under low energy N + implantation manifests oscillations going down with dose strength. From analyzing alfalfa genome DNA under low energy N + implantation by RAPD (Random Amplified Polymorphous DNA), it is recommended that 30 polymorphic DNA fragments be amplified with 8 primers in total 100 primers, and fluorescence intensity of the identical DNA fragment amplified by RAPD is different between CK and treatments. Number of different polymorphic DNA fragments between treatment and CK via N + implantation manifests going up with dose strength

  12. TOTAL HIP ARTHROPLASTY IN OSTEOPETROSIS – REPORT OF A CASE

    Directory of Open Access Journals (Sweden)

    Zmago Krajnc

    2004-04-01

    Full Text Available Background. Authors introduced a case of a 27-year men with osteopetrosis with hip arthrosis. He has an autosomal – dominant form of disease and he needed total hip arthroplasty. There are seven cases described in literature with developed hip arthrosis by osteopetrosis.Methods. TEP implantation represents the greates surgical challenge in this patients, especially creation of intramedullary canal in femur and implantation of the femoral stem because of the very dense and brittle bones. This article describes the operative technique used in the case involved. It proved to be a very good solution.Results. The patient was released from the hospital ten days after implantation of total hip endoprosthesis. Three months after the operation the patient started to walk without aid of canes, he had non pain, and his range of motion was almost normal.Conclusions. Severe coxarthrosis is a rare complication of osteopetrosis. Great care must be taken with implantation of total hip endoprosthesis, especially with preparation of medular canal. It was recommended hand drilling under x-rays to exercise maximal control because reaming can cause false root of stem and greater probability of fracture.

  13. Relationships Among Peripheral and Central Electrophysiological Measures of Spatial and Spectral Selectivity and Speech Perception in Cochlear Implant Users.

    Science.gov (United States)

    Scheperle, Rachel A; Abbas, Paul J

    2015-01-01

    The ability to perceive speech is related to the listener's ability to differentiate among frequencies (i.e., spectral resolution). Cochlear implant (CI) users exhibit variable speech-perception and spectral-resolution abilities, which can be attributed in part to the extent of electrode interactions at the periphery (i.e., spatial selectivity). However, electrophysiological measures of peripheral spatial selectivity have not been found to correlate with speech perception. The purpose of this study was to evaluate auditory processing at the periphery and cortex using both simple and spectrally complex stimuli to better understand the stages of neural processing underlying speech perception. The hypotheses were that (1) by more completely characterizing peripheral excitation patterns than in previous studies, significant correlations with measures of spectral selectivity and speech perception would be observed, (2) adding information about processing at a level central to the auditory nerve would account for additional variability in speech perception, and (3) responses elicited with spectrally complex stimuli would be more strongly correlated with speech perception than responses elicited with spectrally simple stimuli. Eleven adult CI users participated. Three experimental processor programs (MAPs) were created to vary the likelihood of electrode interactions within each participant. For each MAP, a subset of 7 of 22 intracochlear electrodes was activated: adjacent (MAP 1), every other (MAP 2), or every third (MAP 3). Peripheral spatial selectivity was assessed using the electrically evoked compound action potential (ECAP) to obtain channel-interaction functions for all activated electrodes (13 functions total). Central processing was assessed by eliciting the auditory change complex with both spatial (electrode pairs) and spectral (rippled noise) stimulus changes. Speech-perception measures included vowel discrimination and the Bamford-Kowal-Bench Speech

  14. Cochlear implantation in patients with bilateral cochlear trauma.

    Science.gov (United States)

    Serin, Gediz Murat; Derinsu, Ufuk; Sari, Murat; Gergin, Ozgül; Ciprut, Ayça; Akdaş, Ferda; Batman, Cağlar

    2010-01-01

    Temporal bone fracture, which involves the otic capsule, can lead to complete loss of auditory and vestibular functions, whereas the patients without fractures may experience profound sensorineural hearing loss due to cochlear concussion. Cochlear implant is indicated in profound sensorineural hearing loss due to cochlear trauma but who still have an intact auditory nerve. This is a retrospective review study. We report 5 cases of postlingually deafened patients caused by cochlear trauma, who underwent cochlear implantation. Preoperative and postoperative hearing performance will be presented. These patients are cochlear implanted after the cochlear trauma in our department between 2001 and 2006. All patients performed very well with their implants, obtained open-set speech understanding. They all became good telephone users after implantation. Their performance in speech understanding was comparable to standard postlingual adult patients implanted. Cochlear implantation is an effective aural rehabilitation in profound sensorineural hearing loss caused by temporal bone trauma. Preoperative temporal bone computed tomography, magnetic resonance imaging, and promontorium stimulation testing are necessary to make decision for the surgery and to determine the side to be implanted. Surgery could be challenging and complicated because of anatomical irregularity. Moreover, fibrosis and partial or total ossification within the cochlea must be expected. Copyright 2010. Published by Elsevier Inc.

  15. Unconstrained tripolar hip implants: effect on hip stability.

    Science.gov (United States)

    Guyen, Olivier; Chen, Qing Shan; Bejui-Hugues, Jacques; Berry, Daniel J; An, Kai-Nan

    2007-02-01

    Tripolar implants were developed to treat unstable total hip arthroplasties. However, there is limited confirmation that they achieve this purpose despite their increasing use. Because they have a larger effective head size, these implants are expected to increase range of motion to impingement and improve stability in situations at risk for impingement compared with conventional implants. We assessed the range of motion to impingement using a tripolar implant mounted to an automated hip simulator using 22.2-mm and 28-mm femoral head sizes. The 22 and 28-mm tripolar implants provided increases of 30.5 degrees in flexion, 15.4 degrees in adduction, and 22.4 degrees in external rotation compared with the conventional 22.2-mm femoral head diameter implant. At the critical position of 90 degrees hip flexion, there was an increase of 45.2 degrees in internal rotation. At 0 degrees and 30 degrees external rotation, extension increases were 18.8 degrees and 7.8 degrees, respectively. Bony impingement was the limiting factor. Tripolar implants increased the arc of motion before impingement in positions at risk for dislocation and are expected to provide greater stability.

  16. Patient satisfaction with single-tooth implant therapy in the esthetic zone

    NARCIS (Netherlands)

    den Hartog, Laurens; Meijer, Henny J. A.; Santing, Hendrik J.; Vissink, Arjan; Raghoebar, Gerry M.

    2014-01-01

    This prospective study assessed patient satisfaction before and after single-tooth implant therapy in the esthetic zone. Before implant therapy, patients wore an acrylic resin tissue-supported removable partial denture (RPD). A total of 153 patients were included. Self-administered questionnaires

  17. Body fat indices and biomarkers of inflammation: a cross-sectional study with implications for obesity and peri-implant oral health.

    Science.gov (United States)

    Elangovan, Satheesh; Brogden, Kim A; Dawson, Deborah V; Blanchette, Derek; Pagan-Rivera, Keyla; Stanford, Clark M; Johnson, Georgia K; Recker, Erica; Bowers, Rob; Haynes, William G; Avila-Ortiz, Gustavo

    2014-01-01

    To examine the relationships between three measures of body fat-body mass index (BMI), waist circumference (WC), and total body fat percent-and markers of inflammation around dental implants in stable periodontal maintenance patients. Seventy-three subjects were enrolled in this cross-sectional assessment. The study visit consisted of a physical examination that included anthropologic measurements of body composition (BMI, WC, body fat %); intraoral assessments were performed (full-mouth plaque index, periodontal and peri-implant comprehensive examinations) and peri-implant sulcular fluid (PISF) was collected on the study implants. Levels of interleukin (IL)-1α, IL-1β, IL-6, IL-8, IL-10, IL-12, IL-17, tumor necrosis factor-α, C-reactive protein, osteoprotegerin, leptin, and adiponectin in the PISF were measured using multiplex proteomic immunoassays. Correlation analysis with body fat measures was then performed using appropriate statistical methods. After adjustments for covariates, regression analyses revealed statistically significant correlation between IL-1β in PISF and WC (R = 0.33; P = .0047). In this study in stable periodontal maintenance patients, a modest but statistically significant positive correlation was observed between the levels of IL-1β, a major proinflammatory cytokine in PISF, and WC, a reliable measure of central obesity.

  18. Evaluation of the perceptions and cosmetic satisfaction of breast cancer patients undergoing totally implantable vascular access device (TIVAD) placement.

    Science.gov (United States)

    Liberale, Gabriel; El Houkayem, Michel; Viste, Claire; Bouazza, Fikri; Moreau, Michel; El Nakadi, Issam; Veys, Isabelle

    2016-12-01

    Totally implantable vascular access devices (TIVADs) are widely used to administer chemotherapy to cancer patients. While great progress has been made with respect to breast surgical reconstruction to take into account both aesthetics and patients' perceptions of body integrity, these aspects have not been considered with regard to the impact of TIVAD. In order to address this practice gap, we have adapted our TIVAD implantation technique to improve cosmetic results. The aim of this study was to assess breast cancer patients' comfort level and aesthetic satisfaction with regard to TIVAD insertion. Patients with breast cancer admitted for chemotherapy at an outpatient clinic completed a previously validated survey evaluating three main domains: symptoms (pain, discomfort) related to the TIVAD itself in daily activity, information received before and during the surgical procedure, and cosmetic aspects regarding the port insertion site (scar, port, and catheter location). Between September 2010 and June 2011, 232 patients were evaluated. Cosmetic satisfaction with scar location was high (93.3 %). Information given to patients before and during the procedure had a major impact on both symptom perception in daily activity and on cosmetic satisfaction. Obtaining a more aesthetic scar by placing the TIVAD in the deltopectoral groove contributed to a high rate of cosmetic satisfaction. Furthermore, the relevance of information given to patients before and/or during surgery had a major impact on symptom perception. Therefore, we suggest including a pre-operative information session in the care pathway.

  19. Dental Implants in an Aged Population: Evaluation of Periodontal Health, Bone Loss, Implant Survival, and Quality of Life.

    Science.gov (United States)

    Becker, William; Hujoel, Philippe; Becker, Burton E; Wohrle, Peter

    2016-06-01

    To evaluate aged partially and fully edentulous patients who received dental implants and were maintained over time. Further, to determine how the partially and edentulous ageing populations (65 and above) with dental implants maintain bone levels, proper oral hygiene, and perceive benefits of dental implants. Since 1995, patients receiving dental implants have been prospectively entered into an Access-based computerized program (Triton Tacking System). Patient demographics (age, sex), bone quality, quantity, implant location, and type of surgery have been continuously entered into the database. The database was queried for patients receiving implants (first stage) between 66 and 93 years of age. Thirty-one patients were within this age group. Twenty-five patients returned to the clinic for periodontal and dental implant evaluation. The Periodontal Index was used to evaluate selected teeth in terms of probing depth, bleeding on probing, plaque accumulation, and mobility. Using NIH Image J, radiographs taken at second stage and last examination were measured for changes in interproximal bone levels. Once identified, each patient anomalously filled out an abbreviated quality of health life form. Due to small sample size, descriptive statistics were used to compare clinical findings. Fifteen males ranging from 78 to 84 (mean age 84 years) years and 16 females from 66 to 93 (mean age 83 years) (age range 66-93) were contacted by phone or mail and asked to return to our office for a re-examination. For this group, the first dental implants were placed in 1996 (n = initial two implants) and continuously recorded through 2013 (n = last seven implants). Thirty-one patients received a total of 84 implants. Two patients were edentulous, and the remaining were partially edentulous. Four implants were lost. Between implant placement and 6- to 7-year interval, 13 patients with 40 implants had a cumulative survival rate of 94.6%. Of the original group (n = 33), three

  20. [Influence of implants prepared by selective laser melting on early bone healing].

    Science.gov (United States)

    Liu, J Y; Chen, F; Ge, Y J; Wei, L; Pan, S X; Feng, H L

    2018-02-18

    To evaluate the influence of the rough surface of dental implants prepared by selective laser melting (SLM) on early bone healing around titanium implants. A total of sixteen titanium implants were involved in our research, of which eight implants were prepared by SLM (TIXOS Cylindrical, Leader-Novaxa, Milan, Italy; 3.3 mm×10 mm, internal hex) and the other eight were sandblasted, large-grit and acid-etched (SLA) implants (IMPLUS Cylindrical, Leader-Novaxa, Milan, Italy; 3.3 mm×10 mm, internal hex). All of the dental implants were inserted into the healed extraction sockets of the mandible of two adult male Beagle dogs. Half of the dental implants were designed to be healed beneath the mucosa and the other half were intended to be healed transgingivally and were immediately loaded by acrylic resin bridge restoration. Three types of tetracycline fluorescent labels, namely calcein blue, alizarin complexone and calcein, were administered into the veins of the Beagle dogs 2, 4, and 8 weeks after implant placement respectively for fluorescent evaluation of newly formed bone peri-implant. Both Beagle dogs were euthanized 12 weeks after implant insertion and the mandible block specimens containing the titanium implants and surrounding bone and soft tissue of each dog were carefully sectioned and dissected. A total of 16 hard tissue slices were obtained and stained with toluidine blue for microscopic examination and histomorphometric measurements. Histological observation was made for each slice under light microscope and laser scanning confocal microscope (LSCM). Comparison on new bone formation around titanium implants of each group was made and mineral apposition rate (MAR) was calculated for each group. Dental implants prepared by selective laser melting had achieved satisfying osseointegration to surrounding bone tissue after the healing period of 12 weeks. Newly formed bone tissue was observed creeping on the highly porous surface of the SLM implant and growing

  1. Superior versus inferior Ahmed glaucoma valve implantation.

    Science.gov (United States)

    Pakravan, Mohammad; Yazdani, Shahin; Shahabi, Camelia; Yaseri, Mehdi

    2009-02-01

    To compare the efficacy and safety of Ahmed glaucoma valve (AGV) (New World Medical Inc., Rancho Cucamonga, CA) implantation in the superior versus inferior quadrants. Prospective parallel cohort study. A total of 106 eyes of 106 patients with refractory glaucoma. Consecutive patients with refractory glaucoma underwent AGV implantation in the superior or inferior quadrants. Main outcome measures included intraocular pressure (IOP) and rate of complications. Other outcome measures included best corrected visual acuity (BCVA), number of glaucoma medications, and success rate (defined as at least 30% IOP reduction and 5glaucoma surgery, phthisis bulbi, or loss of light perception. Of a total of 106 eyes, 58 and 48 eyes underwent AGV implantation in the superior and inferior quadrants, respectively. Baseline characteristics were comparable in the study groups, except for preoperative IOP, which was higher in the superior group (P = 0.01). Patients were followed for a mean period of 10.6+/-8.49 months and 10.58+/-6.75 months in the superior and inferior groups, respectively (P = 0.477). BCVA was comparable between the groups at all postoperative visits (P>0.122). After 1 year, statistically significant but comparable IOP reduction from baseline (Pglaucoma medications was comparable after 1 year (1.3+/-1.2 vs. 1.9+/-0.8 for superior and inferior implants, respectively, P = 0.256). Success rates were also similar at 1 year: 27 eyes (81.8%) versus 20 eyes (95.2%) for superior and inferior implants, respectively (P = 0.227). However, the overall rate of complications, such as implant exposure necessitating removal, cosmetically unappealing appearance, and endophthalmitis, was higher in the inferior group: 12 eyes (25%) versus 3 eyes (5.2%) for superior and inferior groups, respectively, (P = 0.004). Superior and inferior AGV implants have similar intermediate efficacy in terms of IOP reduction, decrease in number of glaucoma medications, and preservation of vision. However

  2. Animal studies with the Carmat bioprosthetic total artificial heart.

    Science.gov (United States)

    Latrémouille, Christian; Duveau, Daniel; Cholley, Bernard; Zilberstein, Luca; Belbis, Guillaume; Boughenou, Marie-Fazia; Meleard, Denis; Bruneval, Patrick; Adam, Clovis; Neuschwander, Arthur; Perles, Jean-Christophe; Jansen, Piet; Carpentier, Alain

    2015-05-01

    The Carmat bioprosthetic total artificial heart (TAH) contains bioprosthetic blood-contacting surfaces, and is designed for orthotopic cardiac replacement. In preparation for clinical studies, we evaluated the TAH performance and its effects on end-organ function in an animal model. Twelve female Charolais calves, 2-3 months of age and weighing 102-122 kg, were implanted with the TAH through a mid-sternotomy to ensure an adequate anatomic fit. The intended support duration was 4-10 days. Haematological values, creatinine, bilirubin and lactate levels were measured and mean arterial and central venous pressure, central venous oxygen saturation and TAH parameters were monitored. The calves were placed in a cage immediately postoperatively, and extubated on postoperative day 1 in most cases. Average support duration was 3 days, with 4 of 12 calves supported for 4, 4, 8 and 10 days. The initial procedures were used to refine surgical techniques and postoperative care. Pump output ranged from 7.3 to 10 l/min. Haemodynamic parameters and blood analysis were within acceptable ranges. No device failures occurred. No anticoagulation was used in the postoperative phase. The calves were euthanized in case of discomfort compromising the animal well-being, such as respiratory dysfunction, severe blood loss and cerebral dysfunction. Device explant analysis showed no thrombus formation inside the blood cavities. Histological examination of kidneys showed isolated micro-infarction in 2/12 animals; brain histology revealed no thromboembolic depositions. The Carmat bioprosthetic TAH implanted in calves up to 10 days provided adequate blood flow to organs and tissues. Low levels of haemolysis and no visible evidence of thromboembolic depositions in major organs and device cavities, without the use of anticoagulation, may indicate early-phase haemocompatibility of the TAH. © The Author 2015. Published by Oxford University Press on behalf of the European Association for Cardio

  3. Subnanosecond timing with ion-implanted detectors

    International Nuclear Information System (INIS)

    Rijken, H.A.; Klein, S.S.; Jacobs, W.; Teeuwen, L.J.H.G.W.; Voigt, M.J.A. de; Burger, P.

    1992-01-01

    The energy resolution of ion-implanted charged particle detectors may be improved by decreasing the thickness of the implanted detector window to minimize energy straggling. Because of the resistance of this layer, however, the timing depends on the position of entry. Two solutions to this conflict between energy resolution and time resolution are studied: evaporating a very thin aluminum layer on the detector window and fabricating a rectangular detector. Both solutions are shown to be successful with a total time resolution in the low subnanosecond region (<200 ps). (orig.)

  4. Systemic assessment of patients undergoing dental implant surgeries: A trans- and post-operative analysis

    OpenAIRE

    Sanjay Byakodi; Sachin Kumar; Rajesh Kumar Reddy; Vipin Kumar; Shipra Sepolia; Shivangi Gupta; Harkanwal Preet Singh

    2017-01-01

    Background: Procedure-related and patient-related factors influence the prognosis of dental implants to a major extent. Hence, we aimed to evaluate and analyze various systemic factors in patients receiving dental implants. Materials and Methods: Fifty-one patients were included in the study, in which a total of 110 dental implants were placed. Complete examination of the subjects was done before and after placement of dental implants. Implant surgery was planned, and osseointegrated dental i...

  5. Thermal behaviour of nitrogen implanted into zirconium

    International Nuclear Information System (INIS)

    Miyagawa, S.; Ikeyama, M.; Saitoh, K.; Nakao, S.; Niwa, H.; Tanemura, S.; Miyagawa, Y.

    1994-01-01

    Zirconium films were implanted with 15 N ions of energy 50keV to a total fluence of 1x10 18 ionscm -2 in an attempt to study the formation process and thermal stability of ZrN layers produced by high fluence implantation of nitrogen. Subsequent to the implantation at room temperature, samples were annealed at temperatures of 300 C-900 C. The depth profiles of the implanted nitrogen were measured by nuclear reaction analysis using the 15 N(p,αγ) 12 C at E R =429keV, and the surfaces were examined by thin film X-ray diffraction (XRD) and scanning electron microscopy. There were many blisters 0.2-0.4μm in diameter on the surface of the as-implanted samples and double peaks were observed in the nitrogen depth profiles; they were in both sides of the mean projected range. It was found that most of the blisters became extinct after annealing above 400 C, and the XRD peak (111) intensity was increased with the increase in the annealing temperature. Moreover, 14 N and 15 N implantations were superimposed on Zr samples in order to study the atomic migration of nitrogen at each stage of high fluence implantation. It was found that the decrease in the peak at the deeper layers was related to blister extinction and nitrogen diffusion into underling zirconium which could be correlated with radiation damage induced by post-implanted ions. ((orig.))

  6. The influence of implant-abutment connection to peri-implant bone loss: A systematic review and meta-analysis.

    Science.gov (United States)

    Caricasulo, Riccardo; Malchiodi, Luciano; Ghensi, Paolo; Fantozzi, Giuliano; Cucchi, Alessandro

    2018-05-15

    Different implant-abutment connections are available and it has been claimed they could have an effect on marginal bone loss. The aim of this review is to establish if implant connection configuration influences peri-implant bone loss (PBL) after functional loading. A specific question was formulated according to the Population, Intervention, Control, and Outcome (PICO): Does the type of implant-abutment connection (external, internal, or conical) have an influence on peri-implant bone loss? A PubMed/MEDLINE electronic search was conducted to identify English language publications published in international journals during the last decade (from 2006 to 2016). The search was conducted by using the Medical Subject Headings (MeSH) keywords "dental implants OR dental abutment AND external connection OR internal connection OR conical connection OR Morse Taper." Selected studies were randomized clinical trials and prospective studies; in vitro studies, case reports and retrospective studies were excluded. Titles and abstracts and, in the second phase, full texts, were evaluated autonomously and in duplicate by two reviewers. A total of 1649 articles were found, but only 14 studies met the pre-established inclusion criteria and were considered suitable for meta-analytic analysis. The network meta-analysis (NMA) suggested a significant difference between the external and the conical connections; this was less evident for the internal and conical ones. Platform-switching (PS) seemed to positively affect bone levels, non-regarding the implant-connection it was applied to. Within the limitations of this systematic review, it can be concluded that crestal bone levels are better maintained in the short-medium term when internal kinds of interface are adopted. In particular, conical connections seem to be more advantageous, showing lower peri-implant bone loss, but further studies are necessary to investigate the efficacy of implant-abutment connection on stability of crestal

  7. Cochlear implant: the family's perspective.

    Science.gov (United States)

    Vieira, Sheila de Souza; Dupas, Giselle; Chiari, Brasilia Maria

    2018-07-01

    To understand the family's experience of a child who uses a cochlear implant (CI). Specifically, to identify the difficulties, changes, and feelings entailed by deafness and the use of the CI; the coping strategies; and to understand the role of the family for the child with a CI. Qualitative research, using Symbolic Interactionism and Straussian Grounded Theory as the theoretical and methodological frameworks, respectively. Data collection instrument: semi-structured interview. A total of 9 families (32 individuals) participated in the study. The children's ages ranged from 6 to 11 years old (mean = 8.9 years old). Their experience is described in the following categories: Having to fight for results, Coping with difficult situations, Recognizing that you are not alone, Learning to overcome, and Having one's life restored by the implant. Cochlear implantation changes the direction of the child and the family's life by restoring the child's opportunity to hear and to obtain good results in her personal, social, and academic development. Even after implantation, the child continues to experience difficulties and requires the family's mobilization in order to be successful. The family is the principal actor in the process of the child's rehabilitation.

  8. Short dental implants: an emerging concept in implant treatment.

    Science.gov (United States)

    Al-Hashedi, Ashwaq Ali; Taiyeb Ali, Tara Bai; Yunus, Norsiah

    2014-06-01

    Short implants have been advocated as a treatment option in many clinical situations where the use of conventional implants is limited. This review outlines the effectiveness and clinical outcomes of using short implants as a valid treatment option in the rehabilitation of edentulous atrophic alveolar ridges. Initially, an electronic search was performed on the following databases: Medline, PubMed, Embase, Cochrane Database of Systematic Reviews, and DARE using key words from January 1990 until May 2012. An additional hand search was included for the relevant articles in the following journals: International Journal of Oral and Maxillofacial Implants, Clinical Oral Implants Research, Journal of Clinical Periodontology, International Journal of Periodontics, Journal of Periodontology, and Clinical Implant Dentistry and Related Research. Any relevant papers from the journals' references were hand searched. Articles were included if they provided detailed data on implant length, reported survival rates, mentioned measures for implant failure, were in the English language, involved human subjects, and researched implants inserted in healed atrophic ridges with a follow-up period of at least 1 year after implant-prosthesis loading. Short implants demonstrated a high rate of success in the replacement of missing teeth in especially atrophic alveolar ridges. The advanced technology and improvement of the implant surfaces have encouraged the success of short implants to a comparable level to that of standard implants. However, further randomized controlled clinical trials and prospective studies with longer follow-up periods are needed.

  9. Minimally Invasive Catheter Procedures to Assist Complicated Pacemaker Lead Extraction and Implantation in the Operating Room

    International Nuclear Information System (INIS)

    Kröpil, Patric; Lanzman, Rotem S.; Miese, Falk R.; Blondin, Dirk; Winter, Joachim; Scherer, Axel; Fürst, Günter

    2011-01-01

    We report on percutaneous catheter procedures in the operating room (OR) to assist complicated manual extraction or insertion of pacemaker (PM) and implantable cardioverter defibrillator leads. We retrospectively reviewed complicated PM revisions and implantations performed between 2004 and 2009 that required percutaneous catheter procedures performed in the OR. The type of interventional procedure, catheter and retrieval system used, venous access, success rates, and procedural complications were analyzed. In 41 (12 female and 29 male [mean age 62 ± 17 years]) of 3021 (1.4%) patients, standard manual retrieval of old leads or insertion of new leads was not achievable and thus required percutaneous catheter intervention for retrieval of misplaced leads and/or recanalisation of occluded central veins. Thirteen of 18 (72.2%) catheter-guided retrieval procedures for misplaced (right atrium [RA] or ventricle [RV; n = 3], superior vena cava [n = 2], brachiocephalic vein [n = 5], and subclavian vein [n = 3]) lead fragments in 16 patients were successful. Percutaneous catheter retrieval failed in five patients because there were extremely fixed or adhered lead fragments. Percutaneous transluminal angiography (PTA) of central veins for occlusion or high-grade stenosis was performed in 25 patients. In 22 of 25 patients (88%), recanalization of central veins was successful, thus enabling subsequent lead replacement. Major periprocedural complications were not observed. In the case of complicated manual PM lead implantation or revision, percutaneous catheter-guided extraction of misplaced lead fragments or recanalisation of central veins can be performed safely in the OR, thus enabling subsequent implantation or revision of PM systems in the majority of patients.

  10. Dental implants in medically complex patients-a retrospective study.

    Science.gov (United States)

    Manor, Yifat; Simon, Roy; Haim, Doron; Garfunkel, Adi; Moses, Ofer

    2017-03-01

    Dental implant insertion for oral rehabilitation is a worldwide procedure for healthy and medically compromised patients. The impact of systemic disease risks on the outcome of implant therapy is unclear, since there are few if any published randomized controlled trials (RCTs). The objective of this study is to investigate the rate of complications and failures following dental implantation in medically compromised patients in order to elucidate risk factors and prevent them. A retrospective cohort study was conducted from patient files treated with dental implantation between the years 2008-2014. The study group consisted of medically complex patients while the control group consisted of healthy patients. Preoperative, intraoperative, and post operative clinical details were retrieved from patients' files. The survival rate and the success rate of the dental implants were evaluated clinically and radiographically. A total of 204 patients (1003 dental implants) were included in the research, in the study group, 93 patients with 528 dental implants and in the control group, 111 patients with 475 dental implants. No significant differences were found between the groups regarding implant failures or complications. The failure rate of dental implants among the patients was 11.8 % in the study group and 16.2 % in the control group (P = 0.04). It was found that patients with a higher number of implants (mean 6.8) had failures compared with patients with a lower number of implants (mean 4.2) regardless of their health status (P dental implantation in medically complex patients and in healthy patients. Medically complex patients can undergo dental implantation. There are similar rates of complications and failures of dental implants in medically complex patients and in healthy patients.

  11. Cochlear implant: Speech and language development in deaf and hard of hearing children following implantation

    Directory of Open Access Journals (Sweden)

    Ostojić Sanja

    2011-01-01

    Full Text Available Bacground/Aim. Almost 200 cochlear implantations were done in the four centers (two in Belgrade, per one in Novi Sad and Niš in Serbia from 2002 to 2009. Less than 10% of implantees were postlingually deaf adults. The vast majority, i.e. 90% were pre- and perilingually profoundly deaf children. The aim of this study was to assess the influence of improved auditory perception due to cochlear implantation on comprehension of abstract words in children as compared with hearing impaired children with conventional hearing aids and normal hearing children. Methods. Thirty children were enrolled in this study: 20 hearing impaired and 10 normal hearing. The vocabulary test was used. Results. The overall results for the whole test (100 words showed a significant difference in favor of the normal hearing as compared with hearing impaired children. The normal hearing children successfully described or defined 77.93% of a total of 100 words. Success rate for the cochlear implanted children was 26.87% and for the hearing impaired children with conventional hearing aids 20.32%. Conclusion. Testing for abstract words showed a statistically significant difference between the cochlear implanted and the hearing impaired children with hearing aids (Mann- Whitney U-test, p = 0.019 implying considerable advantage of cochlear implants over hearing aids regarding successful speech development in prelingually deaf children.

  12. Iodine-125 orbital brachytherapy with a prosthetic implant in situ

    Energy Technology Data Exchange (ETDEWEB)

    Stannard, Clare [Groote Schuur Hospital and Cape Town Univ. (South Africa). Dept. of Radiation Oncology; Maree, Gert; Munro, Roger [Groote Schuur Hospital and Cape Town Univ. (South Africa). Dept. of Medical Physics; Lecuona, Karin [Groote Schuur Hospital and Cape Town Univ. (South Africa). Dept. of Ophthalmology; Sauerwein, Wolfgang [Universitaetsklinikum Essen (Germany). Strahlenklinik, NCTeam

    2011-05-15

    Purpose: Brachytherapy is one method of irradiating the orbit after enucleation of an eye with a malignant tumor that has a potential to recur. It consists of 6 trains of I-125 seeds placed around the periphery of the orbit, a shorter central train, and a metal disc, loaded with seeds, placed beneath the eyelids. The presence of a prosthetic orbital implant requires omission of the central train and adjustment of the activity of the seeds in the anterior orbit around the prosthesis. Patients and Methods: This is a retrospective review of the technical modifications and outcome of 12 patients treated in this manner: 6 with retinoblastoma, 5 with malignant melanoma, and 1 with an intraocular rhabdomyosarcoma. The median dose was 35.5 Gy in 73 hours for retinoblastoma and 56 Gy in 141 hours for malignant melanoma. Patients with retinoblastoma and rhabdomyosarcoma also received chemotherapy. Results: The tubes can be placed satisfactorily around the prosthesis. The increased activity in the anterior half of the tubes produced comparable dose distributions. There have been no orbital recurrences, no extrusion of the prosthesis, and cosmesis is good. Conclusion: Insertion of a prosthetic implant at the time of enucleation greatly enhances the subsequent cosmetic appearance. This should be encouraged unless there is frank tumor in the orbit. Orbital brachytherapy without the central train continues to give excellent local control. The short treatment time and good cosmesis are added advantages. The patient is spared the expense and inconvenience of removing and replacing the prosthetic implant. (orig.)

  13. Biomechanical evaluation of tibial bone adaptation after revision total knee arthroplasty: A comparison of different implant systems.

    Directory of Open Access Journals (Sweden)

    María Paz Quilez

    Full Text Available The best methods to manage tibial bone defects following total knee arthroplasty remain under debate. Different fixation systems exist to help surgeons reconstruct knee osseous bone loss (such as tantalum cones, cement, modular metal augments, autografts, allografts and porous metaphyseal sleeves However, the effects of the various solutions on the long-term outcome remain unknown. In the present work, a bone remodeling mathematical model was used to predict bone remodeling after total knee arthroplasty (TKA revision. Five different types of prostheses were analyzed: one with a straight stem; two with offset stems, with and without supplements; and two with sleeves, with and without stems. Alterations in tibia bone density distribution and implant Von Mises stresses were quantified. In all cases, the bone density decreased in the proximal epiphysis and medullary channels, and an increase in bone density was predicted in the diaphysis and around stem tips. The highest bone resorption was predicted for the offset prosthesis without the supplement, and the highest bone formation was computed for the straight stem. The highest Von Mises stress was obtained for the straight tibial stem, and the lowest was observed for the stemless metaphyseal sleeves prosthesis. The computational model predicted different behaviors among the five systems. We were able to demonstrate the importance of choosing an adequate revision system and that in silico models may help surgeons choose patient-specific treatments.

  14. Palliative interstitial HDR brachytherapy for recurrent rectal cancer. Implantation techniques and results

    International Nuclear Information System (INIS)

    Kolotas, C.; Roeddiger, S.; Martin, T.; Tselis, N.; Baltas, D.; Zamboglou, N.; Strassmann, G.; Aebersold, D.M.

    2003-01-01

    Purpose: To report the methods and clinical results of CT-based interstitial high-dose-rate (HDR) brachytherapy procedures for the palliative treatment of recurrent rectal cancer. Patients and Methods: A total of 44 brachytherapy implants were performed in 38 patients. CT-guided catheter implants were performed in 34 patients under local anesthesia and sedation, and four patients were implanted intraoperatively. Of 40 CT-guided implants, 20 were done using metallic needles introduced via the sacrum and 20 were transperineal implants of plastic tubes in the presacral region. Postimplant CT scans were used for three-dimensional (3-D) conformal brachytherapy planning. Patients implanted with metallic needles were given a single fraction of 10-15 Gy using HDR 192 Ir, and those who received transperineal implants of plastic catheters were given fractionated brachytherapy, 5 Gy twice daily to a total dose of 30-40 Gy. The median tumor volume was 225 cm 3 with a range of 41-2,103 cm 3 . Results: After a median follow-up of 23.4 months, a total of 13/38 patients were alive. The median postbrachytherapy survival was 15 months with 18 of the 25 deaths due to distant metastases. Tumor response was as follows: 6/38 partial remission, 28/38 stable disease, and 4/38 local progression. A planning target volume (PTV) coverage > 85% was achieved in 42/44 implants. The treatment was well tolerated, and no acute complications were observed. One patient developed a fistula after 8 months. Pain relief was recorded in 34 patients (89.5%), and the median duration of this palliative effect was 5 months with a range of 1-13 months. Conclusions: Interstitial HDR brachytherapy is a valuable tool for the delivery of high doses and achieves effective palliation in recurrent rectal carcinoma. (orig.)

  15. Palliative interstitial HDR brachytherapy for recurrent rectal cancer. Implantation techniques and results

    Energy Technology Data Exchange (ETDEWEB)

    Kolotas, C. [Dept. of Radiation Oncology, Offenbach Hospital, Offenbach (Germany); Dept. of Radio-Oncology, Univ. of Bern, Inselspital, Bern (Switzerland); Roeddiger, S.; Martin, T.; Tselis, N.; Baltas, D.; Zamboglou, N. [Dept. of Radiation Oncology, Offenbach Hospital, Offenbach (Germany); Strassmann, G. [Dept. of Radiotherapy, Univ. Hospital, Philipps Univ., Marburg (Germany); Aebersold, D.M. [Dept. of Radio-Oncology, Univ. of Bern, Inselspital, Bern (Switzerland)

    2003-07-01

    Purpose: To report the methods and clinical results of CT-based interstitial high-dose-rate (HDR) brachytherapy procedures for the palliative treatment of recurrent rectal cancer. Patients and Methods: A total of 44 brachytherapy implants were performed in 38 patients. CT-guided catheter implants were performed in 34 patients under local anesthesia and sedation, and four patients were implanted intraoperatively. Of 40 CT-guided implants, 20 were done using metallic needles introduced via the sacrum and 20 were transperineal implants of plastic tubes in the presacral region. Postimplant CT scans were used for three-dimensional (3-D) conformal brachytherapy planning. Patients implanted with metallic needles were given a single fraction of 10-15 Gy using HDR {sup 192}Ir, and those who received transperineal implants of plastic catheters were given fractionated brachytherapy, 5 Gy twice daily to a total dose of 30-40 Gy. The median tumor volume was 225 cm{sup 3} with a range of 41-2,103 cm{sup 3}. Results: After a median follow-up of 23.4 months, a total of 13/38 patients were alive. The median postbrachytherapy survival was 15 months with 18 of the 25 deaths due to distant metastases. Tumor response was as follows: 6/38 partial remission, 28/38 stable disease, and 4/38 local progression. A planning target volume (PTV) coverage > 85% was achieved in 42/44 implants. The treatment was well tolerated, and no acute complications were observed. One patient developed a fistula after 8 months. Pain relief was recorded in 34 patients (89.5%), and the median duration of this palliative effect was 5 months with a range of 1-13 months. Conclusions: Interstitial HDR brachytherapy is a valuable tool for the delivery of high doses and achieves effective palliation in recurrent rectal carcinoma. (orig.)

  16. Number of implants for mandibular implant overdentures: a systematic review

    Science.gov (United States)

    Lee, Jeong-Yol; Kim, Ha-Young; Bryant, S. Ross

    2012-01-01

    PURPOSE The aim of this systematic review is to address treatment outcomes of Mandibular implant overdentures relative to implant survival rate, maintenance and complications, and patient satisfaction. MATERIALS AND METHODS A systematic literature search was conducted by a PubMed search strategy and hand-searching of relevant journals from included studies. Randomized Clinical Trials (RCT) and comparative clinical trial studies on mandibular implant overdentures until August, 2010 were selected. Eleven studies from 1098 studies were finally selected and data were analyzed relative to number of implants. RESULTS Six studies presented the data of the implant survival rate which ranged from 95% to 100% for 2 and 4 implant group and from 81.8% to 96.1% for 1 and 2 implant group. One study, which statistically compared implant survival rate showed no significant differences relative to the number of implants. The most common type of prosthetic maintenance and complications were replacement or reattaching of loose clips for 2 and 4 implant group, and denture repair due to the fracture around an implant for 1 and 2 implant groups. Most studies showed no significant differences in the rate of prosthetic maintenance and complication, and patient satisfaction regardless the number of implants. CONCLUSION The implant survival rate of mandibular overdentures is high regardless of the number of implants. Denture maintenance is likely not inflenced substantially by the number of implants and patient satisfaction is typically high again regardless os the number of implants. PMID:23236572

  17. Cochlear implant after bacterial meningitis.

    Science.gov (United States)

    Bille, Jesper; Ovesen, Therese

    2014-06-01

    The aim of this retrospective case study at a tertiary referral center was to investigate the outcome of cochlear implantation (CI) in children with sensorineural hearing loss due to meningitis compared to CI in children with deafness due to other reasons. This post-meningial group (PMG) consisted of 22 children undergoing CI due to deafness induced by meningitis, between December 1996 and January 2012. Five children had bilateral simultaneous implantation. None was excluded and the children were followed for at least 3 years. Operations were carried out by one of two surgeons using similar techniques in all cases. Each patient from the PMG was matched 2:1 with children having implantation for other reasons according to age and follow up (control group). Overall, the median category of auditory performance (CAP) and speech intelligibility rating (SIR) score were not statistically significantly different between the two groups. The presence of additional central nervous system (CNS) disorders (post-meningeal sequelae), however, correlated significantly with poorer outcome CI was a safe procedure without surgical complications in the present study. It is possible to restore auditory capacity and speech performance to a degree comparable to children undergoing implantation for other reasons. A statistically important variable is secondary CNS involvement. The rehabilitation program after CI should be adjusted according to these additional handicaps. It is recommended to screen meningitis patients as fast as possible to identify those with hearing loss and initiate treatment with hearing aids or CI. © 2013 The Authors. Pediatrics International © 2013 Japan Pediatric Society.

  18. Role of interstitial implantation in gynecological cancer

    International Nuclear Information System (INIS)

    Nori, D.; Hilaris, B.S.

    1987-01-01

    Recurrent cancer at any site carries a gloomy prognosis. Cancer of the cervix that recurs after radical surgery or curative radiation therapy is a perplexing problem confronting both gynecological and radiation oncologists. In the authors' series, 45% of the patients survived disease-free at 1 year and 10% survived without disease at 5 years or longer following interstitial implantation for recurrent cervical cancer. The optimal utilization of this procedure seems to depend on the site of recurrence, the extent of the disease in the pelvis, and the status of para-aortic node involvement. This retrospective analysis enabled the authors to identify the prognostic factors. The most favorable group benefited by this technique were those who presented with either central recurrence or unilateral, localized pelvic side wall recurrent disease. The least morbidity was noticed in those patients with minimal surgical manipulations at the time of the interstitial implantation. The authors recommended that only a limited and essential surgical procedure should accompany interstitial implantation, since the associated morbidity and mortality is high and survival brief

  19. Considerations regarding tax optimization in implanted multinational enterprises through external growth for the automobile industry in Central Eastern Europe

    Directory of Open Access Journals (Sweden)

    Nitu Antonie Renata

    2008-04-01

    Full Text Available The business strategy of multinational enterprises (MNEs from the automobile industry implanted in Central-Eastern European (CEE countries (Poland, Czech Republic and Romania is an offensive one, global from operational perspective. Mainly it aims the extension of market share through horizontal growth, generally external type single-domain (Mergers and Acquisitions and internal type (Greenfield investments in a lower degree. These enterprises put in practice also a defending strategy for the owned market shares through increasing the efficiency of the production network at global level. This paper aims to present the less evident aspects of tax optimization of the applied business strategy by implemented MNEs in the automobile industry in CEE, and in this context, the necessity to establish transfer prices in accordance with the OECD recommendations, as an obligation assessed by the tax legislations of the considered countries, but also from the necessity of efficient run of these enterprises.

  20. Long-Term Experience with First-Generation Implantable Neurostimulation Device in Central Sleep Apnea Treatment.

    Science.gov (United States)

    Fox, Henrik; Bitter, Thomas; Horstkotte, Dieter; Oldenburg, Olaf; Gutleben, Klaus-Jürgen

    2017-05-01

    Sleep-disordered breathing (SDB) and Cheyne-Stokes respiration (CSR) are associated with shorter survival in patients with heart failure. A novel treatment method for this patient group is unilateral phrenic nerve stimulation by the remedē® system (Respicardia Inc., Minnetonka, MN, USA), a transvenously implantable neurostimulation device, which has recently been studied in a large randomized, controlled trial. Previous literature has shown efficacy and safety of the treatment with this first-generation device, but hardly any data are available on long-term clinical parameters, the remedē® device's battery lifetime, device exchangeability, lead position stability, surgical accessibility, and manageability. We performed remedē® device replacements in consecutive patients for battery depletion, and documented clinical parameters, longevity, operation procedure, complications, and difficulties. All patients were on neurostimulation treatment by phrenic nerve neurostimulation when device replacement became necessary. Apnea-hypopnea index (from 45 ± 4/h to 9 ± 4/h), oxygen-desaturation index (from 35 ± 7/h to 7 ± 6/h), and time spent with oxygen saturation of ray documentation of stable lead positions in a long-term setting, no radiation or contrast dye usage was needed and no major complications occurred. In addition, clinical exercise capacity and sleepiness symptoms improved. Novel remedē® device shows sustained therapy efficacy and safety in terms of stable lead positions over 4 years. Long-term phrenic nerve neurostimulation therapy for central SDB/CSR appears feasible in a clinical routine setting. © 2017 Wiley Periodicals, Inc.

  1. The role of hinges in primary total knee replacement.

    Science.gov (United States)

    Gehrke, T; Kendoff, D; Haasper, C

    2014-11-01

    The use of hinged implants in primary total knee replacement (TKR) should be restricted to selected indications and mainly for elderly patients. Potential indications for a rotating hinge or pure hinge implant in primary TKR include: collateral ligament insufficiency, severe varus or valgus deformity (>20°) with necessary relevant soft-tissue release, relevant bone loss including insertions of collateral ligaments, gross flexion-extension gap imbalance, ankylosis, or hyperlaxity. Although data reported in the literature are inconsistent, clinical results depend on implant design, proper technical use, and adequate indications. We present our experience with a specific implant type that we have used for over 30 years and which has given our elderly patients good mid-term results. Because revision of implants with long cemented stems can be very challenging, an effort should be made in the future to use shorter stems in modular versions of hinged implants. ©2014 The British Editorial Society of Bone & Joint Surgery.

  2. Primary prevention of peri-implantitis: managing peri-implant mucositis.

    Science.gov (United States)

    Jepsen, Søren; Berglundh, Tord; Genco, Robert; Aass, Anne Merete; Demirel, Korkud; Derks, Jan; Figuero, Elena; Giovannoli, Jean Louis; Goldstein, Moshe; Lambert, France; Ortiz-Vigon, Alberto; Polyzois, Ioannis; Salvi, Giovanni E; Schwarz, Frank; Serino, Giovanni; Tomasi, Cristiano; Zitzmann, Nicola U

    2015-04-01

    Over the past decades, the placement of dental implants has become a routine procedure in the oral rehabilitation of fully and partially edentulous patients. However, the number of patients/implants affected by peri-implant diseases is increasing. As there are--in contrast to periodontitis--at present no established and predictable concepts for the treatment of peri-implantitis, primary prevention is of key importance. The management of peri-implant mucositis is considered as a preventive measure for the onset of peri-implantitis. Therefore, the remit of this working group was to assess the prevalence of peri-implant diseases, as well as risks for peri-implant mucositis and to evaluate measures for the management of peri-implant mucositis. Discussions were informed by four systematic reviews on the current epidemiology of peri-implant diseases, on potential risks contributing to the development of peri-implant mucositis, and on the effect of patient and of professionally administered measures to manage peri-implant mucositis. This consensus report is based on the outcomes of these systematic reviews and on the expert opinion of the participants. Key findings included: (i) meta-analysis estimated a weighted mean prevalence for peri-implant mucositis of 43% (CI: 32-54%) and for peri-implantitis of 22% (CI: 14-30%); (ii) bleeding on probing is considered as key clinical measure to distinguish between peri-implant health and disease; (iii) lack of regular supportive therapy in patients with peri-implant mucositis was associated with increased risk for onset of peri-implantitis; (iv) whereas plaque accumulation has been established as aetiological factor, smoking was identified as modifiable patient-related and excess cement as local risk indicator for the development of peri-implant mucositis; (v) patient-administered mechanical plaque control (with manual or powered toothbrushes) has been shown to be an effective preventive measure; (vi) professional intervention

  3. Clinical and Radiologic Outcomes of Submerged and Nonsubmerged Bone-Level Implants with Internal Hexagonal Connections in Immediate Implantation: A 5-Year Retrospective Study.

    Science.gov (United States)

    Wu, Shiyu; Wu, Xiayi; Shrestha, Rachana; Lin, Jinying; Feng, Zhicai; Liu, Yudong; Shi, Yunlin; Huang, Baoxin; Li, Zhipeng; Liu, Quan; Zhang, Xiaocong; Hu, Mingxuan; Chen, Zhuofan

    2018-02-01

    To evaluate the 5-year clinical and radiologic outcome of immediate implantation using submerged and nonsubmerged techniques with bone-level implants and internal hexagonal connections and the effects of potential influencing factors. A total of 114 bone-level implants (XiVE S plus) with internal hexagonal connections inserted into 72 patients were included. Patients were followed up for 5 years. A t-test was used to statistically evaluate the marginal bone loss between the submerged and nonsubmerged groups. The cumulative survival rate (CSR) was calculated according to the life table method and illustrated with Kaplan-Meier survival curves. Comparisons of the CSR between healing protocols, guided bone regeneration, implants with different sites, lengths, and diameters were performed using log-rank tests. The 5-year cumulative implant survival rates with submerged and nonsubmerged healing were 94% and 96%, respectively. No statistically significant differences in terms of marginal bone loss, healing protocol, application of guided bone regeneration, implant site, or length were observed. High CSRs and good marginal bone levels were achieved 5 years after immediate implantation of bone-level implants with internal hexagonal connections using both the submerged and nonsubmerged techniques. Factors such as implant length, site, and application of guided bone regeneration did not have an impact on the long-term success of the implants. © 2017 by the American College of Prosthodontists.

  4. Functional and oncologic outcomes after excision of the total femur in primary bone tumors: Results with a low cost total femur prosthesis

    Directory of Open Access Journals (Sweden)

    Ajay Puri

    2012-01-01

    Full Text Available Background: The extent of tumor may necessitate resection of the complete femur rarely to achieve adequate oncologic clearance in bone sarcomas. We present our experience with reconstruction in such cases using an indigenously manufactured, low-cost, total femoral prosthesis (TFP. We assessed the complications of the procedure, the oncologic and functional outcomes, and implant survival. Materials and Methods: Eight patients (four males and four females with a mean age of 32 years, operated between December 2003 and June 2009, had a TFP implanted. The diagnosis included osteogenic sarcoma (5, Ewing′s sarcoma (1, and chondrosarcoma (2. Mean followup was 33 months (9-72 months for all and 40 months (24-72 months in survivors. They were evaluated by Musculoskeletal Tumor Society score, implant survival as well as patient survival. Results: There was one local recurrence and five of seven patients are currently alive at the time of last followup. The Musculoskeletal Tumor Society score for patients ranged from 21 to 25 with a mean of 24 (80%. The implant survival was 88% at 5 years with only one TFP needing removal because of infection. Conclusions: A TFP in appropriately indicated patients with malignant bone tumors is oncologically safe. A locally manufactured, cost-effective implant provided consistent and predictable results after excision of the total femur with good functional outcomes.

  5. Peripheral Insertion of a Central Venous Access Device Under Fluoroscopic Guidance Using a Peripherally Accessed System (PAS) Port in the Forearm

    International Nuclear Information System (INIS)

    Hata, Yasuhiro; Morita, Sojiro; Morita, Yoshitaka; Awatani, Toshihide; Takasaki, Motohiro; Horimi, Tadashi; Ozawa, Zen

    1998-01-01

    Purpose: We describe the technique, efficacy, and complications of fluoroscopy-guided implantation of a central venous access device using a peripherally accessed system (PAS) port via the forearm. Methods: Beginning in July 1994, 105 central venous access devices were implanted in 104 patients for the long-term infusion of antibiotics or antineoplasmic agents, blood products, or parenteral nutrition. The devices was inserted under fluoroscopic guidance with real-time venography from a peripheral route. Results: All ports were successfully implanted. There were no procedure-related complications. No thrombosis or local infection was observed; however, in six patients catheter-related phlebitis occurred. Conclusion: Fluoroscopy-guided implantation of a central venous access device using a PAS port via the forearm is safe and efficacious, and injection of contrast medium through a peripheral IV catheter before introduction of the catheter helps to avoid catheter-related phlebitis

  6. Magnetic resonance imaging of an equine fracture model containing stainless steel metal implants.

    Science.gov (United States)

    Pownder, S L; Koff, M F; Shah, P H; Fortier, L A; Potter, H G

    2016-05-01

    Post operative imaging in subjects with orthopaedic implants is challenging across all modalities. Magnetic resonance imaging (MRI) is preferred to assess human post operative musculoskeletal complications, as soft tissue and bones are evaluated without using ionising radiation. However, with conventional MRI pulse sequences, metal creates susceptibility artefact that distorts anatomy. Assessment of the post operative equine patient is arguably more challenging due to the volume of metal present, and MRI is often not performed in horses with implants. Novel pulse sequences such as multiacquisition variable resonance image combination (MAVRIC) now provide improved visibility in the vicinity of surgical-grade implants and offer an option for imaging horses with metal implants. To compare conspicuity of regional anatomy in an equine fracture-repair model using MAVRIC, narrow receiver bandwidth (NBW) fast spin echo (FSE), and wide receiver bandwidth (WBW) FSE sequences. Nonrandomised in vitro experiment. MAVRIC, NBW FSE and WBW FSE were performed on 9 cadaveric distal limbs with fractures and stainless steel implants in the third metacarpal bone and proximal phalanx. Objective measures of artefact reduction were performed by calculating the total artefact area in each transverse image as a percentage of the total anatomic area. The number of transverse images in which fracture lines were visible was tabulated for each sequence. Regional soft tissue conspicuity was assessed subjectively. Overall anatomic delineation was improved using MAVRIC compared with NBW FSE; delineation of structures closest to the metal implants was improved using MAVRIC compared with WBW FSE and NBW FSE. Total artefact area was the highest for NBW FSE and lowest for MAVRIC; the total number of transverse slices with a visible fracture line was highest in MAVRIC and lowest in NBW FSE. MAVRIC and WBW FSE are feasible additions to minimise artefact around implants. © 2015 EVJ Ltd.

  7. Longstanding refractory pseudophakic cystoid macular edema resolved using intravitreal 0.7 mg dexamethasone implants

    Directory of Open Access Journals (Sweden)

    Brynskov T

    2013-06-01

    Full Text Available Troels Brynskov,1,2 Caroline Schmidt Laugesen,1 Jakob Halborg,1 Henrik Kemp,1 Torben Lykke Sørensen1,21Department of Ophthalmology, Copenhagen University Hospital Roskilde, Roskilde, Denmark; 2Faculty of Health Sciences, University of Copenhagen, Copenhagen, DenmarkBackground: Refractory pseudophakic cystoid macular edema (PCME following cataract surgery has long posed a challenge to clinicians, but intravitreal injections with a sustained delivery 0.7 mg dexamethasone implant has emerged as a promising therapy for this condition.Objective: To present a case of longstanding and refractory PCME with complete remission through 189 days of follow-up after two successive injections with intravitreal dexamethasone implants.Case report: A 59-year-old male had experienced metamorphopsia for approximately 4 years and had been diagnosed with PCME 15 months earlier. Since the time of the diagnosis, the condition had been refractory to both subtenon triamcinolone acetonide and a total of five injections with intravitreal ranibizumab. After the last injection with ranibizumab, central subfield mean thickness was 640 µm, and the best corrected visual acuity was 78 Early Treatment Diabetic Retinopathy Study letters. Following an intravitreal injection with a dexamethasone implant, the macular edema resolved at the next follow-up. The macular edema returned 187 days after the first injection and was treated with another intravitreal dexamethasone implant. Again, the macular edema subsided completely, and best corrected visual acuity improved to 84 Early Treatment Diabetic Retinopathy Study letters, a condition which was maintained through an additional 189 days of follow-up.Conclusion: Chronic PCME is traditionally a difficult condition to treat, but we are encouraged by the optimal response experienced with intravitreal sustained release dexamethasone implants in our patient whose longstanding PCME had been refractory to previous treatments with both

  8. Monitoring failure rates of commercial implant brands; substantial equivalence in question?

    Science.gov (United States)

    Hujoel, Philippe; Becker, William; Becker, Burton

    2013-07-01

    The aim of this study was to report on the failure rates of two distinct dental implant systems in a clinical practice setting. Date of implant placement and loss were entered prospectively in a data registry system. Failure rates of two commercially pure titanium implants, one with a porous oxydized surface (POS) and the other with a chemically altered surface (CAS), were assessed using a quality control chart and survival analyses. A total of 860 POS and 759 CAS implants were placed. A warning of an increased failure rate of the CAS implant was identified by means of the quality control chart. Survival analyses indicated that the CAS implant failure rate was twice that of the POS implant (Hazard Ratio: 2.08; 95% CI: 1.33-3.28, P-value POS implant was associated with a non-significant 64% drop in the implant failure rate within less than a year (HR: 0.36; 95% CI: 0.12-1.14; P-value POS implant and an 8% failure with the CAS implant appears inconsistent with the assumption of substantial equivalence. © 2012 John Wiley & Sons A/S.

  9. Failure of Emperion modular femoral stem with implant analysis

    Directory of Open Access Journals (Sweden)

    Benjamin M. Stronach, MD, MS

    2016-03-01

    Full Text Available Modularity in total hip arthroplasty provides multiple benefits to the surgeon in restoring the appropriate alignment and position to a previously damaged hip joint. The vast majority of modern implants incorporate modularity into their design with some implants having multiple modular interfaces. There is the potential for failure at modular junctions because of fretting and crevice corrosion in combination with mechanical loading. This case report details the failure of an Emperion (Smith and Nephew, Memphis, TN femoral stem in a 67-year-old male patient 6 years after total hip replacement. Analysis of the implant revealed mechanically assisted crevice corrosion that likely accelerated fatigue crack initiation in the hip stem. The benefits of modularity come with the potential drawback of a combination of fretting and crevice corrosion at the modular junction, which may accelerate fatigue, crack initiation and ultimately reduce the hip longevity.

  10. Scalloped Implant-Abutment Connection Compared to Conventional Flat Implant-Abutment Connection

    DEFF Research Database (Denmark)

    Starch-Jensen, Thomas; Christensen, Ann-Eva; Lorenzen, Henning

    2017-01-01

    OBJECTIVES: The objective was to test the hypothesis of no difference in implant treatment outcome after installation of implants with a scalloped implant-abutment connection compared to a flat implant-abutment connection. MATERIAL AND METHODS: A MEDLINE (PubMed), Embase and Cochrane library search...... of suprastructures has never been compared within the same study. High implant survival rate was reported in all the included studies. Significantly more peri-implant marginal bone loss, higher probing depth score, bleeding score and gingival score was observed around implants with a scalloped implant-abutment...... loss around implants with a scalloped implant-abutment connection. CONCLUSIONS: A scalloped implant-abutment connection seems to be associated with higher peri-implant marginal bone loss compared to a flat implant-abutment connection. Therefore, the hypothesis of the present systematic review must...

  11. Immediately loaded zygomatic implants vs conventional dental implants in augmented atrophic maxillae: 4 months post-loading results from a multicentre randomised controlled trial.

    Science.gov (United States)

    Esposito, Marco; Davó, Rubén; Marti-Pages, Carlos; Ferrer-Fuertes, Ada; Barausse, Carlo; Pistilli, Roberto; Ippolito, Daniela Rita; Felice, Pietro

    2018-01-01

    To compare the clinical outcome of immediately loaded cross-arch maxillary prostheses supported by zygomatic implants vs conventional implants placed in augmented bone. A total of 71 edentulous patients with severely atrophic maxillas, who did not have sufficient bone volume to place dental implants or when it was possible to place only two implants in the front area (minimal diameter 3.5 mm and length of 8 mm) and less than 4.0 mm of bone height subantrally, were randomised according to a parallel group design. They (35 patients) received zygomatic implants to be loaded immediately vs grafting with a xenograft, followed, after 6 months of graft consolidation, by the placement of six to eight conventional dental implants, submerged for 4 months (36 patients). To be loaded immediately, zygomatic implants had to be inserted with an insertion torque superior to 40 Ncm. Screw-retained, metal-reinforced, acrylic provisional prostheses were provided to be replaced by definitive Procera Implant Bridge Titanium prostheses (Nobel Biocare, Göteborg, Sweden) with ceramic or acrylic veneer materials 4 months after initial loading. Outcome measures were: prosthesis, implant and augmentation failures, any complications, quality of life (OHIP-14), the number of days that patients experienced total or partial impaired activity, time to function, and number of dental visits, assessed by independent assessors. Patients were followed up to 4 months after loading. No augmentation procedure failed. Three patients dropped out from the augmentation group. Six prostheses could not be delivered or failed in the augmentation group vs one prosthesis in the zygomatic group, the difference being statistically significant (difference in proportions = 15.32%; P = 0.04; 95% CI: 0.23 to 31.7). Eight patients lost 35 implants in the augmentation group vs three implants in one patient from the zygomatic group, the difference being statistically significant (difference in proportions = 21.38%; P = 0

  12. Application of ion implantation in stevia breeding

    International Nuclear Information System (INIS)

    Wang Cailian; Chen Qiufang; Jin Wei; Lu Ting; Shu Shizhen

    1999-08-01

    Dry seed of stevia were implanted with 60-100 keV nitrogen ion and 75 keV carbon ion of various doses, and the effects of the composition and yield of stevioside were studied. The results showed that ion beam could induce variation in total stevioside yield and the composition of the plant. The best treatment was 75 keV nitrogen ion with 5 x 10 14 N + /cm 2 , the stevioside yield and Rebaudioside A (R-A) content were increased by 4.74% and 14.08% respectively. The effects induced by implantation of carbon ion were higher than those induced by implantation of nitrogen ion. Effects of Feng 1 x Ri Yuan and Ri Yuan x Feng 2 are higher than those of Ji Ning and Feng 2 . Seven mutation lines were selected from the mutation progenies. The stevioside composition of these lines were previously improved. The results suggest a potential application of ion implantation in stevia breeding

  13. Immunological Responses to Total Hip Arthroplasty.

    Science.gov (United States)

    Man, Kenny; Jiang, Lin-Hua; Foster, Richard; Yang, Xuebin B

    2017-08-01

    The use of total hip arthroplasties (THA) has been continuously rising to meet the demands of the increasingly ageing population. To date, this procedure has been highly successful in relieving pain and restoring the functionality of patients' joints, and has significantly improved their quality of life. However, these implants are expected to eventually fail after 15-25 years in situ due to slow progressive inflammatory responses at the bone-implant interface. Such inflammatory responses are primarily mediated by immune cells such as macrophages, triggered by implant wear particles. As a result, aseptic loosening is the main cause for revision surgery over the mid and long-term and is responsible for more than 70% of hip revisions. In some patients with a metal-on-metal (MoM) implant, metallic implant wear particles can give rise to metal sensitivity. Therefore, engineering biomaterials, which are immunologically inert or support the healing process, require an in-depth understanding of the host inflammatory and wound-healing response to implanted materials. This review discusses the immunological response initiated by biomaterials extensively used in THA, ultra-high-molecular-weight polyethylene (UHMWPE), cobalt chromium (CoCr), and alumina ceramics. The biological responses of these biomaterials in bulk and particulate forms are also discussed. In conclusion, the immunological responses to bulk and particulate biomaterials vary greatly depending on the implant material types, the size of particulate and its volume, and where the response to bulk forms of differing biomaterials are relatively acute and similar, while wear particles can initiate a variety of responses such as osteolysis, metal sensitivity, and so on.

  14. Long-term Results of 185 Consecutive Osseointegrated Hearing Device Implantations

    DEFF Research Database (Denmark)

    Calvo Bodnia, Nadia; Foghsgaard, Søren; Nue Møller, Martin

    2014-01-01

    , and discomfort resulting in abutment and/or implant removal. RESULTS: One hundred eighty-five implantations in 176 patients were reviewed. Overall, 3.8% of the implants were lost spontaneously after a mean of 2.5 years. Implant loss in children was 18% versus 2.5% in adults and 3.8% in elderly. Adverse skin...... reactions occurred in 14% of observations overall; in 10% in children compared with 16% in adults and 9% in elderly. Partial or total skin overgrowth was seen in 4% and 6% of the observations in children and adults, respectively, whereas none of the elderly experienced this problem. The abutment was removed...... common complication. Children lose the implant more frequently than adults. Elderly patients have less adverse skin reactions/skin overgrowth. Discomfort leading to abutment removal is a concern especially among adults....

  15. Erythritol-Enriched Air-Polishing Powder for the Surgical Treatment of Peri-Implantitis

    Directory of Open Access Journals (Sweden)

    Silvio Taschieri

    2015-01-01

    Full Text Available Peri-implantitis represents a major complication that can compromise the success and survival of implant-supported rehabilitations. Both surgical and nonsurgical treatment protocols were proposed to improve clinical parameters and to treat implants affected by peri-implantitis. A systematic review of the literature was performed on electronic databases. The use of air-polishing powder in surgical treatment of peri-implantitis was investigated. A total of five articles, of different study designs, were included in the review. A meta-analysis could not be performed. The data from included studies reported a substantial benefit of the use of air-polishing powders for the decontamination of implant surface in surgical protocols. A case report of guided bone regeneration in sites with implants affected by peri-implantitis was presented. Surgical treatment of peri-implantitis, though demanding and not supported by a wide scientific literature, could be considered a viable treatment option if an adequate decontamination of infected surfaces could be obtained.

  16. Effect of thermal annealing on optical properties of implanted GaAs

    NARCIS (Netherlands)

    Kulik, M; Komarov, FF; Maczka, D

    GaAs samples doped with indium atoms by ion implantation and thermal annealed were studied using a channelling method, Rutherford backscattering, and an ellipsometry. From these measurements it was observed that the layer implanted with 3 x 10(16) cm(-2) indium dose was totally damaged and its

  17. «Implantation window» disturbance in patients with hyperplastic processes of endometrium

    Directory of Open Access Journals (Sweden)

    O. I. Parnytska

    2013-12-01

    Full Text Available Introduction There is an increasing interest in the role of hyperplastic processes of endometrium in the “implantation window” disturbance and unsuccessful implantation rate. The endometrium represents a barrier to implantation except under appropriate and defined hormonal conditions. There is no doubt that endometrium has an important role for embryo implantation at early stages of development. Successful implantation requires a functionally normal embryo at the blastocyst stage and receptive endometrium, while the communication between them is also vital. Endometrium shows dynamic and cyclic morphological changes throughout the follicular phase and in the secretory phase. The progesterone-driven differentiative changes in the endometrial epithelium lead to the ‘opening’ of the “window of receptivity” for blastocyst implantation. Morphologically, progesterone-dependent apical cellular protrusions known as pinopods (uterodomes become visible by scanning electron microscopy on 20th–21st days of human menstrual cycle and then are lost. Materials and methods A total of 180 endometrial specimens from women with simple hyperplasia (I gr., endometrial polyps (II gr. and asynchronous endometrium (III gr. have been examined by scanning electron microscopy. Biopsies were obtained from fundus of the uterus and processed for light and scanning electron microscopy. Tissues for light microscopy were fixed in 1,25% glutardialdehyde, embedded in paraffin, sectioned and stained with hematoxylin and eosin. Results In I group with simple hyperplasia the ratio of glands and stroma is now increased. Most or all of the endometrial glands are more or less cystically dilated and lined by pseudostratified, highly proliferating epithelium with enlarged, elongated, nuclei in scanty, basophilic cytoplasm. Mitoses are frequent in the epithelium. II group shows endometrial polyps with proliferation of stromal cells incorporating a non-neoplastic glandular

  18. Microbiota in experimental periodontitis and peri-implantitis in dogs.

    Science.gov (United States)

    Charalampakis, Georgios; Abrahamsson, Ingemar; Carcuac, Olivier; Dahlén, Gunnar; Berglundh, Tord

    2014-09-01

    To analyze the microbial profile around teeth and implants following ligature removal in experimental periodontitis and peri-implantitis in dogs. Four implants with similar geometry and with two different surface characteristics (implant A: turned/implant B: TiUnite; NobelBiocare AB) were placed pairwise in the right side of the mandible 3 months after tooth extraction in five dogs. Experimental periodontitis and peri-implantitis were initiated 3 months later by ligature placement around implants and mandibular premolars and plaque formation. The ligatures were removed after 10 weeks. Microbial samples were obtained using paper points immediately after ligature removal, at 10 and 25 weeks after ligature removal. The microbiological analysis was performed by "checkerboard" DNA-DNA hybridization, including a panel of 16 bacterial species. The amount of bone loss that occurred during the period following ligature removal was significantly larger at implants with a modified surface than at implants with a turned surface and at teeth. The microbiological analysis revealed that the total bacterial load increased during the period following ligature removal and established an anaerobic Gram-negative microflora. It is suggested that the large variation in regard to the microbial profiles makes interpretation of a correlation between disease progression and microbial profiles difficult. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  19. The effect of implant macro-thread design on implant stability in the early post-operative period: a randomized, controlled pilot study.

    Science.gov (United States)

    McCullough, Jeffrey J; Klokkevold, Perry R

    2017-10-01

    Available literature suggests there is a transient drop in implant stability from approximately week 0 to week 3-4 as a result of peri-implant bone remodeling as it transitions from a primary, mechanical stability to a secondary, biological stability. Research investigating the influence of macro-thread design on this process is scant. The specific aim of this study was to evaluate the role of macro-thread design on implant stability in the early post-operative healing period using resonance frequency analysis (RFA). Seven patients, each missing at least two posterior teeth in the same arch, were included in the study. Three patients qualified for four implants resulting in a total of 10 matched pairs. All sites were healed (>6 months), non-grafted sites with sufficient bone to place implants. Each site in a matched pair was randomly assigned to receive either a control (Megagen EZ Plus Internal; EZ) or test (Megagen AnyRidge; AR) implant. The test implant incorporates a novel thread design with a wide thread depth and increased thread pitch. RFA was used to determine implant stability quotient (ISQ) values for each implant at the time of placement and weekly for the first 8 weeks. Implants consistently achieved a relatively high insertion torque (30-45 N/cm) and high initial ISQ value (79.8 ± 1.49). Baseline ISQ values for test (AR; 79.55 ± 1.61) and control (EZ; 80.05 ± 1.37) implants were similar. A general pattern of stability from baseline through all eight follow-up evaluations was observed for the test implants. A pattern of decreasing ISQ values was observed for the control implants across the early follow-up evaluations up to week four, where the value plateaued. There was a statistically significant main effect due to implant type (P implant type and time (P implants performed differently at certain time points. Within the limitations of this study, macro-thread design appears to play a role in implant stability in the early post

  20. Percutaneous dilatational tracheostomy following total artificial heart implantation.

    Science.gov (United States)

    Spiliopoulos, Sotirios; Dimitriou, Alexandros Merkourios; Serrano, Maria Rosario; Guersoy, Dilek; Autschbach, Ruediger; Goetzenich, Andreas; Koerfer, Reiner; Tenderich, Gero

    2015-07-01

    Coagulation disorders and an immune-altered state are common among total artificial heart patients. In this context, we sought to evaluate the safety of percutaneous dilatational tracheostomy in cases of prolonged need for mechanical ventilatory support. We retrospectively analysed the charts of 11 total artificial heart patients who received percutaneous dilatational tracheostomy. We focused on early and late complications. We observed no major complications and no procedure-related deaths. Early minor complications included venous oozing (45.4%) and one case of local infection. Late complications, including subglottic stenosis, stomal infection or infections of the lower respiratory tract, were not observed. In conclusion, percutaneous dilatational tracheostomy in total artificial heart patients is safe. Considering the well-known benefits of early tracheotomy over prolonged translaryngeal intubation, we advocate early timing of therapy in cases of prolonged mechanical ventilation. © The Author 2015. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  1. Influence of cochlear implantation on peripheral vestibular receptor function.

    Science.gov (United States)

    Krause, Eike; Louza, Julia P R; Wechtenbruch, Juliane; Gürkov, Robert

    2010-06-01

    The objectives of this study were 1) to assess the influence of a cochlear implantation on peripheral vestibular receptor function in the inner ear in the implant and in the nonimplant side, and 2) to analyze a possible correlation with resulting vertigo symptoms. Prospective clinical study. Cochlear implant center at tertiary referral hospital. A total of 32 patients, aged 15 to 83 years, undergoing cochlear implantation were assessed pre- and postoperatively for caloric horizontal semicircular canal response and vestibular-evoked myogenic potentials of the sacculus, and postoperatively for subjective vertigo symptoms. Patients with vertigo were compared with patients without symptoms with regard to the findings of the vestibular function tests. Cochlear implantation represents a significant risk factor for horizontal semicircular canal impairment (P 0.05). Cochlear implantation is a relevant risk factor for damage of peripheral vestibular receptor function. Therefore, preservation not only of residual hearing function but also of vestibular function should be aimed for, by using minimally invasive surgical techniques. Copyright 2010 American Academy of Otolaryngology-Head and Neck Surgery Foundation. Published by Mosby, Inc. All rights reserved.

  2. Quality of life after permanent prostate implant

    International Nuclear Information System (INIS)

    Arterbery, V. Elayne; Frazier, Arthur; Dalmia, Praveen; Porter, Arthur

    1997-01-01

    procedure to a friend. Of the patients who had full time employment (38), 96% returned to work after the implant and the majority returned within 5 days. Sexual quality was high in this short follow up after seed implant. 89% of potent patients retained sexual function after implant. 3% noted some discomfort with ejaculation. 12% noticed some decrease in sexual desire. Interestingly, 14% experienced an increase in sexual desire. 79% reported an excellent overall quality of life. Conclusions: While survival is clearly a central goal of treatment for prostate cancer, the nature of this malignancy compels clinical attention to the qualitative content of the patients life after treatment. Permanent prostate implant has a high degree of patient tolerance and patient acceptance. Sexual quality and function are maintained in the majority of patients and they have minimal interruption in their social and economic function. The low morbidity and high quality of life associated with implantation make it a viable treatment option

  3. Comparison of optical quality after implantable collamer lens implantation and wavefront-guided laser in situ keratomileusis

    Directory of Open Access Journals (Sweden)

    Hong-Ting Liu

    2018-04-01

    Full Text Available AIM: To compare the optical quality after implantation of implantable collamer lens (ICL and wavefront-guided laser in situ keratomileusis (WG-LASIK. METHODS: The study included 40 eyes of 22 patients with myopia who accepted ICL implantation and 40 eyes of 20 patients with myopia who received WG-LASIK. Before surgery and three months after surgery, the objective scattering index (OSI, the values of modulation transfer function (MTF cutoff frequency, Strehl ratio, and the Optical Quality Analysis System (OQAS values (OVs were accessed. The higher order aberrations (HOAs data including coma, trefoil, spherical, 2nd astigmatism and tetrafoil were also obtained. For patients with pupil size <6 mm, HOAs data were analyzed for 4 mm-pupil diameter. For patients with pupil size ≥6 mm, HOAs data were calculated for 6 mm-pupil diameter. Visual acuity, refraction, pupil size and intraocular pressures were also recorded. RESULTS: In both ICL and WG-LASIK group, significant improvements in visual acuities were found postoperatively, with a significant reduction in spherical equivalent (P< 0.001. After the ICL implantation, the OSI decreased slightly from 2.34±1.92 to 2.24±1.18 with no statistical significance (P=0.62. While in WG-LASIK group, the OSI significantly increased from 0.68±0.43 preoperatively to 0.91±0.53 postoperatively (Wilcoxon signed ranks test, P=0.000. None of the mean MTF cutoff frequency, Strehl ratio, OVs showed statistically significant changes in both ICL and WG-LASIK groups. In the ICL group, there were no statistical differences in the total HOAs for either 4 mm-pupil or 6 mm-pupil. In the WG-LASIK group, the HOA parameters increased significantly at 4 mm-pupil. The total ocular HOAs, coma, spherical and 2nd astigmatism were 0.12±0.06, 0.06±0.03, 0.00±0.03, 0.02±0.01, respectively. After the operation, these values were increased into 0.16±0.07, 0.08±0.05, -0.04±0.04, 0.03±0.01 respectively (Wilcoxon signed ranks test

  4. Effects of seed migration on post-implant dosimetry of prostate brachytherapy

    International Nuclear Information System (INIS)

    Gao, M.; Wang, J. Z.; Nag, S.; Gupta, N.

    2007-01-01

    Brachytherapy using permanent seed implants has been an effective treatment for prostate cancer. However, seeds will migrate after implant, thus making the evaluation of post-implant dosimetry difficult. In this study, we developed a computer program to simulate seed migration and analyzed dosimetric changes due to seed migration at various migration amounts. The study was based on 14 patients treated with Pd-103 at the James Cancer Hospital. Modeling of seed migration, including direction, distance as well as day of migration, was based on clinical observations. Changes of commonly used dosimetric parameters as a function of migration amount (2, 4, 6 mm respectively), prostate size (from 20 to 90 cc), and prostate region (central vs peripheral) were studied. Change of biological outcome (tumor control probability) due to migration was also estimated. Migration reduced prostate D90 to 99±2% of original value in 2 mm migration, and the reduction increased to 94±6% in 6 mm migration. The reduction of prostate dose led to a 14% (40%) drop in the tumor control probability for 2 mm (6 mm) migration, assuming radiosensitive tumors. However, migration has less effect on a prostate implanted with a larger number of seeds. Prostate V100 was less sensitive to migration than D90 since its mean value was still 99% of original value even in 6 mm migration. Migration also showed a different effect in the peripheral region vs the central region of the prostate, where the peripheral mean dose tended to drop more significantly. Therefore, extra activity implanted in the peripheral region during pre-plan can be considered. The detrimental effects of migration were more severe in terms of increasing the dose to normal structures, as rectum V50 may be 70% higher and urethra V100 may be 50% higher in the case of 6 mm migration. Quantitative knowledge of these effects is helpful in treatment planning and post-implant evaluation

  5. Finite element analysis (FEA) of dental implant fixture for mechanical stability and rapid osseointegration

    Science.gov (United States)

    Tabassum, Shafia; Murtaza, Ahmar; Ali, Hasan; Uddin, Zia Mohy; Zehra, Syedah Sadaf

    2017-10-01

    For rapid osseointegration of dental implant fixtures, various surface treatments including plasma spraying, hydroxyapatite coating, acid-etching, and surface grooving are used. However undesirable effects such as chemical modifications, loss of mechanical properties, prolonged processing times and post production treatment steps are often associated with these techniques. The osseointegration rate of the dental implants can be promoted by increasing the surface area of the dental implant, thus increasing the bone cells - implant material contact and allow bone tissues to grow rapidly. Additive Manufacturing (AM) techniques can be used to fabricate dental implant fixtures with desirable surface area in a single step manufacturing process. AM allows the use of Computer Aided Designing (CAD) for customised rapid prototyping of components with precise control over geometry. In this study, the dental implant fixture that replaces the tooth root was designed on commercially available software COMSOL. Nickel - titanium alloy was selected as build materials for dental implant. The geometry of the dental fixture was varied by changing the interspacing distance (thread pitch) and number of threads to increase the total surface area. Three different microstructures were introduced on the surface of dental implant. The designed models were used to examine the effect of changing geometries on the total surface area. Finite Element Analysis (FEA) was performed to investigate the effect of changing geometries on the mechanical properties of the dental implant fixtures using stress analysis.

  6. Long-term outcomes of dental implants placed in elderly patients: a retrospective clinical and radiographic analysis.

    Science.gov (United States)

    Park, Jung-Chul; Baek, Won-Sun; Choi, Seong-Ho; Cho, Kyoo-Sung; Jung, Ui-Won

    2017-02-01

    The aim of this retrospective study was to determine the clinical and the radiographic outcomes of dental implants placed in elderly people older than 65 years. In total, 902 implants in 346 patients (age: 65-89 years) were followed up for 2-17 years following the implant surgery. The survival rate of these implants was recorded and analyzed. Changes in marginal bone levels were also analyzed in serial radiographs, and Cox regression analysis for implant loss was performed. The survival rates were 95.39% and 99.98% in the implant- and patient-based analyses, respectively (involving a total of 29 implant failures), and the marginal bone loss at the implants was 0.17 ± 0.71 mm (mean ± SD). The number of failures was greatest in patients aged 65-69 years. The Cox regression with shared frailty analysis showed that implant loss was significantly greater in those aged 65-69 years than in those aged 70-74 years (P implant systems. Within the limitations of this retrospective study, it was concluded that implant therapy can be successfully provided to elderly patients and that age alone does not seem to affect the implant survival rate. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  7. Penile implants among prisoners-a cause for concern?

    Directory of Open Access Journals (Sweden)

    Lorraine Yap

    Full Text Available BACKGROUND: We report the prevalence of penile implants among prisoners and determine the independent predictors for having penile implants. Questions on penile implants were included in the Sexual Health and Attitudes of Australian Prisoners (SHAAP survey following concerns raised by prison health staff that increasing numbers of prisoners reported having penile implants while in prison. METHODS: Computer-Assisted Telephone Interviewing (CATI of a random sample of prisoners was carried out in 41 prisons in New South Wales and Queensland (Australia. Men were asked, "Have you ever inserted or implanted an object under the skin of your penis?" If they responded Yes: "Have you ever done so while you were in prison?" Univariate logistic regression and logistic regression were used to determine the factors associated with penile implants. RESULTS: A total of 2,018 male prisoners were surveyed, aged between 18 and 65 years, and 118 (5.8% reported that they had inserted or implanted an object under the skin of their penis. Of these men, 87 (73% had this done while they were in prison. In the multivariate analysis, a younger age, birth in an Asian country, and prior incarceration were all significantly associated with penile implants (p<0.001. Men with penile implants were also more likely to report being paid for sex (p<0.001, to have had body piercings (p<0.001 or tattoos in prison (p<0.001, and to have taken non-prescription drugs while in prison (p<0.05. CONCLUSIONS: Penile implants appear to be fairly common among prisoners and are associated with risky sexual and drug use practices. As most of these penile implants are inserted in prison, these men are at risk of blood borne viruses and wound infection. Harm reduction and infection control strategies need to be developed to address this potential risk.

  8. Fracture of Reduced-Diameter Zirconia Dental Implants Following Repeated Insertion.

    Science.gov (United States)

    Karl, Matthias; Scherg, Stefan; Grobecker-Karl, Tanja

    Achievement of high insertion torque values indicating good primary stability is a goal during dental implant placement. The objective of this study was to evaluate whether or not two-piece implants made from zirconia ceramic may be damaged as a result of torque application. A total of 10 two-piece zirconia implants were repeatedly inserted into polyurethane foam material with increasing density and decreasing osteotomy size. The insertion torque applied was measured, and implants were checked for fractures by applying the fluorescent penetrant method. Weibull probability of failure was calculated based on the recorded insertion torque values. Catastrophic failures could be seen in five of the implants from two different batches at insertion torques ranging from 46.0 to 70.5 Ncm, while the remaining implants (all belonging to one batch) survived. Weibull probability of failure seems to be low at the manufacturer-recommended maximum insertion torque of 35 Ncm. Chipping fractures at the thread tips as well as tool marks were the only otherwise observed irregularities. While high insertion torques may be desirable for immediate loading protocols, zirconia implants may fracture when manufacturer-recommended insertion torques are exceeded. Evaluating bone quality prior to implant insertion may be useful.

  9. Pacemaker Implants in Children and Adolescents with Chagas Disease in Brazil: 18-Year Incidence.

    Science.gov (United States)

    Mizzaci, Carolina Christianini; Souza, Thiago Gonçalves Schroder E; Targueta, Gabriel Pelegrineti; Tótora, Ana Paula Frederico; Mateos, Juan Carlos Pachón; Mateos, José Carlos Pachon

    2017-06-01

    Chagas disease continues to be a serious public health problem, and accounts for 25-30% of the indications for cardiac stimulation in Brazil. To assess clinical and epidemiological characteristics of patients with Chagas disease, younger than 18 years, who had undergone pacemaker implantation in Brazil between 1994 and 2011, and its temporal trend. This was a cross-sectional analysis of data from the Brazilian Pacemaker Registry database. The following variables were analyzed: year when pacemaker was implanted, location, age, sex, ethnic group, functional class and the main electrocardiographic findings at baseline. In a total of 183,123 implants performed between 1994 and 2011, 214 implants of cardiac stimulation device in Chagas disease patients aged younger than 18 years were identified. Mean age at implantation was 5.6 ± 6.2 years. Second- and third-degree atrioventricular blocks corresponded to 71% of indications for pacemaker implantation. Fifty-six percent of the procedures were performed in the southeast region. Regarding the total number of pacemaker implants per year, there was a remarkable increase in the implants for all causes. However, time series analysis of the implants in Chagas disease patients younger than 18 years revealed a significant reduction in the annual number of implants. There has been an important reduction in the number of pacemaker implantations among children and adolescents with Chagas disease, suggesting a reduction in the vertical transmission of the parasite. A doença de Chagas mantém-se como sério problema de saúde pública e tem sido responsável por aproximadamente 25% a 30% das indicações de estimulação cardíaca no Brasil. Estudar as características clínicas e epidemiológicas dos pacientes menores de 18 anos portadores de doença de Chagas submetidos a implante de marca-passo no território brasileiro entre 1994 e 2011, e sua tendência temporal. Trata-se de um estudo retrospectivo que utilizou informa

  10. Novel implant for peri-prosthetic proximal tibia fractures.

    Science.gov (United States)

    Tran, Ton; Chen, Bernard K; Wu, Xinhua; Pun, Chung Lun

    2018-03-01

    Repair of peri-prosthetic proximal tibia fractures is very challenging in patients with a total knee replacement or arthroplasty. The tibial component of the knee implant severely restricts the fixation points of the tibial implant to repair peri-prosthetic fractures. A novel implant has been designed with an extended flange over the anterior of tibial condyle to provide additional points of fixation, overcoming limitations of existing generic locking plates used for proximal tibia fractures. Furthermore, the screws fixed through the extended flange provide additional support to prevent the problem of subsidence of tibial component of knee implant. The design methodology involved extraction of bone data from CT scans into a flexible CAD format, implant design and structural evaluation and optimisation using FEM as well as prototype development and manufacture by selective laser melting 3D printing technology with Ti6Al4 V powder. A prototype tibia implant was developed based on a patient-specific bone structure, which was regenerated from the CT images of patient's tibia. The design is described in detail and being applied to fit up to 80% of patients, for both left and right sides based on the average dimensions and shape of the bone structure from a wide range of CT images. A novel tibial implant has been developed to repair peri-prosthetic proximal tibia fractures which overcomes significant constraints from the tibial component of existing knee implant. Copyright © 2018 Elsevier Ltd. All rights reserved.

  11. Primary prevention of peri-implantitis: Managing peri-implant mucositis

    OpenAIRE

    Jepsen, Søren; Berglundh, Tord; Genco, Robert; Aass, Anne Merete; Demirel, Korkud; Derks, Jan; Figuero, Elena; Giovannoli, Jean Louis; Goldstein, Moshe; LAMBERT, France; Ortiz-Vigon, Alberto; Polyzois, Ioannis; Salvi, Giovanni; Schwarz, Frank; Serino, Giovanni

    2015-01-01

    Abstract AIMS: Over the past decades, the placement of dental implants has become a routine procedure in the oral rehabilitation of fully and partially edentulous patients. However, the number of patients/implants affected by peri-implant diseases is increasing. As there are--in contrast to periodontitis--at present no established and predictable concepts for the treatment of peri-implantitis, primary prevention is of key importance. The management of peri-implant mucositis is considere...

  12. Tinnitus after Simultaneous and Sequential Bilateral Cochlear Implantation.

    Science.gov (United States)

    Ramakers, Geerte G J; Kraaijenga, Véronique J C; Smulders, Yvette E; van Zon, Alice; Stegeman, Inge; Stokroos, Robert J; Free, Rolien H; Frijns, Johan H M; Huinck, Wendy J; Van Zanten, Gijsbert A; Grolman, Wilko

    2017-01-01

    There is an ongoing global discussion on whether or not bilateral cochlear implantation should be standard care for bilateral deafness. Contrary to unilateral cochlear implantation, however, little is known about the effect of bilateral cochlear implantation on tinnitus. To investigate tinnitus outcomes 1 year after bilateral cochlear implantation. Secondarily, to compare tinnitus outcomes between simultaneous and sequential bilateral cochlear implantation and to investigate long-term follow-up (3 years). This study is a secondary analysis as part of a multicenter randomized controlled trial. Thirty-eight postlingually deafened adults were included in the original trial, in which the presence of tinnitus was not an inclusion criterion. All participants received cochlear implants (CIs) because of profound hearing loss. Nineteen participants received bilateral CIs simultaneously and 19 participants received bilateral CIs sequentially with an inter-implant interval of 2 years. The prevalence and severity of tinnitus before and after simultaneous and sequential bilateral cochlear implantation were measured preoperatively and each year after implantation with the Tinnitus Handicap Inventory (THI) and Tinnitus Questionnaire (TQ). The prevalence of preoperative tinnitus was 42% (16/38). One year after bilateral implantation, there was a median difference of -8 (inter-quartile range (IQR): -28 to 4) in THI score and -9 (IQR: -17 to -9) in TQ score in the participants with preoperative tinnitus. Induction of tinnitus occurred in five participants, all in the simultaneous group, in the year after bilateral implantation. Although the preoperative and also the postoperative median THI and TQ scores were higher in the simultaneous group, the median difference scores were equal in both groups. In the simultaneous group, tinnitus scores fluctuated in the 3 years after implantation. In the sequential group, four patients had an additional benefit of the second CI: a total

  13. Implantable cardioverter defibrillator specific rehabilitation improves health cost outcomes

    DEFF Research Database (Denmark)

    Berg, Selina Kikkenborg; Zwisler, Ann-Dorthe; Koch, Mette Bjerrum

    2015-01-01

    OBJECTIVE: The Copenhagen Outpatient ProgrammE - implantable cardioverter defibrillator (COPE-ICD) trial included patients with implantable cardioverter defibrillators in a randomized controlled trial of rehabilitation. After 6-12 months significant differences were found in favour of the rehabil...... was -6,789 USD/-5,593 Euro in favour of rehabilitation. CONCLUSION: No long-term health outcome benefits were found for the rehabilitation programme. However, the rehabilitation programme resulted in a reduction in total attributable direct costs....... of the rehabilitation group for exercise capacity, general and mental health. The aim of this paper is to explore the long-term health effects and cost implications associated with the rehabilitation programme; more specifically, (i) to compare implantable cardioverter defibrillator therapy history and mortality...... between rehabilitation and usual care groups; (ii) to examine the difference between rehabilitation and usual care groups in terms of time to first admission; and (iii) to determine attributable direct costs. METHODS: Patients with first-time implantable cardioverter defibrillator implantation (n = 196...

  14. [Cochlear implantation in patients with Waardenburg syndrome type II].

    Science.gov (United States)

    Wan, Liangcai; Guo, Menghe; Chen, Shuaijun; Liu, Shuangriu; Chen, Hao; Gong, Jian

    2010-05-01

    To describe the multi-channel cochlear implantation in patients with Waardenburg syndrome including surgeries, pre and postoperative hearing assessments as well as outcomes of speech recognition. Multi-channel cochlear implantation surgeries have been performed in 12 cases with Waardenburg syndrome type II in our department from 2000 to 2008. All the patients received multi-channel cochlear implantation through transmastoid facial recess approach. The postoperative outcomes of 12 cases were compared with 12 cases with no inner ear malformation as a control group. The electrodes were totally inserted into the cochlear successfully, there was no facial paralysis and cerebrospinal fluid leakage occurred after operation. The hearing threshold in this series were similar to that of the normal cochlear implantation. After more than half a year of speech rehabilitation, the abilities of speech discrimination and spoken language of all the patients were improved compared with that of preoperation. Multi-channel cochlear implantation could be performed in the cases with Waardenburg syndrome, preoperative hearing and images assessments should be done.

  15. Osteogenesis and Morphology of the Peri-Implant Bone Facing Dental Implants

    Directory of Open Access Journals (Sweden)

    Marco Franchi

    2004-01-01

    Full Text Available This study investigated the influence of different implant surfaces on peri-implant osteogenesis and implant face morphology of peri-implant tissues during the early (2 weeks and complete healing period (3 months. Thirty endosseous titanium implants (conic screws with differently treated surfaces (smooth titanium = SS, titanium plasma sprayed = TPS, sand-blasted zirconium oxide = Zr-SLA were implanted in femur and tibiae diaphyses of two mongrel sheep. Histological sections of the implants and surrounding tissues obtained by sawing and grinding techniques were observed under light microscopy (LM. The peri-implant tissues of other samples were mechanically detached from the corresponding implants to be processed for SEM observation. Two weeks after implantation, we observed osteogenesis (new bone trabeculae around all implant surfaces only where a gap was present at the host bone-metal interface. No evident bone deposition was detectable where threads of the screws were in direct contact with the compact host bone. Distance osteogenesis predominated in SS implants, while around rough surfaces (TPS and Zr-SLA, both distance and contact osteogenesis were present. At SEM analysis 2 weeks after implantation, the implant face of SS peri-implant tissue showed few, thin, newly formed, bone trabeculae immersed in large, loose, marrow tissue with blood vessels. Around the TPS screws, the implant face of the peri-implant tissue was rather irregular because of the rougher metal surface. Zr-SLA screws showed more numerous, newly formed bone trabeculae crossing marrow spaces and also needle-like crystals in bone nodules indicating an active mineralising process. After 3 months, all the screws appeared osseointegrated, being almost completely covered by a compact, mature, newly formed bone. However, some marrow spaces rich in blood vessels and undifferentiated cells were in contact with the metal surface. By SEM analysis, the implant face of the peri-implant

  16. Ion beam investigation of hydrogen implanted in magnesium

    International Nuclear Information System (INIS)

    Chami, A.-C.

    1977-01-01

    The diffusion mechanism for hydrogen implanted in magnesium was investigated by nuclear reaction analysis or channeling. The hydrogen introduced is then in the presence of radiation defects created by implantation. The H( 11 B,α) reaction used allowed the profiles of implanted hydrogen to be drawn. The Winterbon calculations derived from LSS theory (Lindhard, Scharff, Schiott) were used. LSS profiles folding and the excitation curve unfolding give very same results. An analysis of the profile of the defects and the evaluation of the total number of Frenkel pairs produced show that the defects are isolated when low energy light elements are implanted, and hydrogen interactions are effected through point defects. A channeling analysis shows that hydrogen occupies tetrahedral sites as far as the temperature remains lower that the migration temperature (about 100K). Beyonds this temperature, the hydrogen migrates and is trapped on motionless defects [fr

  17. Accuracy of Implants Placed with Surgical Guides: Thermoplastic Versus 3D Printed.

    Science.gov (United States)

    Bell, Caitlyn K; Sahl, Erik F; Kim, Yoon Jeong; Rice, Dwight D

    This study was conducted to evaluate the accuracy of implants placed using two different guided implant surgery materials: thermoplastic versus three-dimensionally (3D) printed. A cone beam computed tomography (CBCT) scan previously obtained and selected for single-tooth implant replacement was converted into a Digital Imaging and Communications in Medicine (DICOM) file. All models were planned and exported for printing using BlueSkyBio Plan Software with the DICOM files. A total of 20 3D-printed mandibular quadrant jaws replicating the CBCT were printed by Right Choice Milling, as was the control model to accept the control implant. Previously, 10 thermoplastic and 10 3D-printed surgical guides had been made by the same lab technician at Right Choice Milling. One Nobel Biocare implant with a trilobe connection was placed per guide and replica jaw model pair. Implants were placed using the thermoplastic and 3D-printed surgical guides, representing the two test groups, following the Nobel Biocare guided surgical protocol. A total of 21 CBCT scans were then taken, one for the control implant and one for each test implant. The CBCT volume was converted to a DICOM file and transferred to Invivo5 software version 5.4 (Anatomage). The DICOM file of each test implant was superimposed over the DICOM file of the control. The deviation of the head of the implant, the deviation of the apex of the implant, and the angle of deviation were evaluated from measurements on the superimposition of the control and test implants. Mann-Whitney U test was used to test the null hypotheses at α = .05 and a confidence interval of 95%. Descriptive statistics were used for the average ± standard deviation. The implants placed with the thermoplastic surgical guides showed an average of 3.40 degrees of angular deviation compared to 2.36 degrees for implants placed with the 3D-printed surgical guides (P = .143). The implants placed with the thermoplastic surgical guides showed an average of 1

  18. Survival of dental implants placed in sites of previously failed implants.

    Science.gov (United States)

    Chrcanovic, Bruno R; Kisch, Jenö; Albrektsson, Tomas; Wennerberg, Ann

    2017-11-01

    To assess the survival of dental implants placed in sites of previously failed implants and to explore the possible factors that might affect the outcome of this reimplantation procedure. Patients that had failed dental implants, which were replaced with the same implant type at the same site, were included. Descriptive statistics were used to describe the patients and implants; survival analysis was also performed. The effect of systemic, environmental, and local factors on the survival of the reoperated implants was evaluated. 175 of 10,096 implants in 98 patients were replaced by another implant at the same location (159, 14, and 2 implants at second, third, and fourth surgeries, respectively). Newly replaced implants were generally of similar diameter but of shorter length compared to the previously placed fixtures. A statistically significant greater percentage of lost implants were placed in sites with low bone quantity. There was a statistically significant difference (P = 0.032) in the survival rates between implants that were inserted for the first time (94%) and implants that replaced the ones lost (73%). There was a statistically higher failure rate of the reoperated implants for patients taking antidepressants and antithrombotic agents. Dental implants replacing failed implants had lower survival rates than the rates reported for the previous attempts of implant placement. It is suggested that a site-specific negative effect may possibly be associated with this phenomenon, as well as the intake of antidepressants and antithrombotic agents. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  19. Sub-meninges implantation reduces immune response to neural implants.

    Science.gov (United States)

    Markwardt, Neil T; Stokol, Jodi; Rennaker, Robert L

    2013-04-15

    Glial scar formation around neural interfaces inhibits their ability to acquire usable signals from the surrounding neurons. To improve neural recording performance, the inflammatory response and glial scarring must be minimized. Previous work has indicated that meningeally derived cells participate in the immune response, and it is possible that the meninges may grow down around the shank of a neural implant, contributing to the formation of the glial scar. This study examines whether the glial scar can be reduced by placing a neural probe completely below the meninges. Rats were implanted with sets of loose microwire implants placed either completely below the meninges or implanted conventionally with the upper end penetrating the meninges, but not attached to the skull. Histological analysis was performed 4 weeks following surgical implantation to evaluate the glial scar. Our results found that sub-meninges implants showed an average reduction in reactive astrocyte activity of 63% compared to trans-meninges implants. Microglial activity was also reduced for sub-meninges implants. These results suggest that techniques that isolate implants from the meninges offer the potential to reduce the encapsulation response which should improve chronic recording quality and stability. Published by Elsevier B.V.

  20. Permanent pace maker implantation through axillary vein approach

    International Nuclear Information System (INIS)

    Shah, B.; Hussain, C.; Awan, Z.A.

    2017-01-01

    Device implantation is an integral part of interventional cardiology particularly electrophysiology. In this study, we are going to share our experience of device implantation technique at electrophysiology department Hayatabad Medical Complex, Peshawar. Methods: the study was conducted from June 2011 to December 2015. Axillary vein was used to implant the devices but in some cases when this rout was not convenient due to any reason then subclavian vein was entered through the Seldinger technique. Fluoroscopy time was less than 10 minutes and total procedure time was not more than 45 minutes. Electric cautery was used only in two cases. Pressure dressing was used in a few cases. Results: Total numbers of permanent pacemakers (PPM) remain 800 during the study period. There were 450 single chamber pacemakers and 350 dual chambers pacemakers. No case of any major bleeding was documented and in very few cases there was mild ooze from the procedure site after the operation which was tackled with pressure dressing. Four cases of pneumothorax were noted during the study period and in three cases chest intubation were done and one patient was kept on conservative management. Patient were followed after one month of discharge from the hospital and then yearly. Eight cases of lead dislodgment were documented during the study period. Conclusion: Axillary vein approach for implantation of permanent pacemakers is a safe and less time-consuming technique. (author)

  1. Does the real-time ultrasound guidance provide safer venipuncture in implantable venous port implantation?

    Science.gov (United States)

    Yıldırım, İlknur; Tütüncü, Ayşe Çiğdem; Bademler, Süleyman; Özgür, İlker; Demiray, Mukaddes; Karanlık, Hasan

    2018-03-01

    To examine whether the real-time ultrasound-guided venipuncture for implantable venous port placement is safer than the traditional venipuncture. The study analyzed the results of 2153 venous ports placed consecutively from January 2009 to January 2016. A total of 922 patients in group 1 and 1231 patients in group 2 were admitted with venous port placed using the traditional landmark subclavian approach and real-time ultrasound-guided axillary approach, respectively. Sociodemographic characteristics of patients, early (pneumothorax, pinch-off syndrome, arterial puncture, hematoma, and malposition arrhythmia) and late (deep vein thrombosis, obstruction, infection, erosion-dehiscence, and rotation of the port chamber) complications and the association of these complications with the implantation method were evaluated. There were no significant differences in the sociodemographic characteristics of the patients between the two groups. The overall and early complications in group 2 were significantly lower than those in group 1. Pinch-off syndrome only developed in group 1. Seven patients and two patients had pneumothorax in groups 1 and 2, respectively. Puncture number was significantly associated with the development of the overall complications. The ultrasound-guided axillary approach may be preferred as a method to reduce the risk of both early and late complications. Large, randomized, controlled prospective trials will be helpful in determining a safer implantable venous port implantation technique.

  2. Bicruciate-retaining Total Knee Replacement Provides Satisfactory Function and Implant Survivorship at 23 Years.

    Science.gov (United States)

    Pritchett, James W

    2015-07-01

    One of the goals of a TKA is to approximate the function of a normal knee. Preserving the natural ligaments might provide a method of restoring close to normal function. Sacrifice of the ACL is common and practical during a TKA. However, this ligament is functional in more than 60% of patients undergoing a TKA and kinematic studies support the concept of bicruciate-retaining (that is, ACL-preserving) TKA; however, relatively few studies have evaluated patients treated with bicruciate-retaining TKA implants. I asked: (1) what is the long-term (minimum 20-year) survivorship, (2) what are the functional results, and (3) what are the reasons for revision of bicruciate-retaining knee arthroplasty prostheses? From January 1989 to September 1992, I performed 639 total knee replacements in 537 patients. Of these, 489 were performed in 390 patients using a bicruciate-retaining, minimally constrained device. During the period in question, this knee prosthesis was used for all patients observed intraoperatively to have an intact, functional ACL with between 15° varus and 15° valgus joint deformity. There were 234 women and 156 men with a mean age at surgery of 65 years (range, 42-84 years) and a primary diagnosis of osteoarthritis in 89%. The patella was resurfaced in all knees. The mean followup was 23 years (range, 20-24 years). At the time of this review, 199 (51%) patients had died and 31 (8%) patients were lost to followup, leaving 160 (41%) patients (214 knees) available for review. Component survivorship was determined by competing-risks analysis and Kaplan Meier survivorship analysis with revision for any reason as the primary endpoint. Patients were evaluated every 2 years to assess ROM, joint laxity, knee stability, and to determine American Knee Society scores. The Kaplan-Meier survivorship was 89% (95% CI, 82%-93%) at 23 years with revision for any reason as the endpoint. Competing-risks survivorship was 94% (95% CI, 91%%-96 %) at 23 years. At followup, the mean

  3. Scalloped Implant-Abutment Connection Compared to Conventional Flat Implant-Abutment Connection

    DEFF Research Database (Denmark)

    Starch-Jensen, Thomas; Christensen, Ann-Eva; Lorenzen, Henning

    2017-01-01

    OBJECTIVES: The objective was to test the hypothesis of no difference in implant treatment outcome after installation of implants with a scalloped implant-abutment connection compared to a flat implant-abutment connection. MATERIAL AND METHODS: A MEDLINE (PubMed), Embase and Cochrane library search......-abutment connection. There were no significant differences between the two treatment modalities regarding professional or patient-reported outcome measures. Meta-analysis disclosed a mean difference of peri-implant marginal bone loss of 1.56 mm (confidence interval: 0.87 to 2.25), indicating significant more bone...... loss around implants with a scalloped implant-abutment connection. CONCLUSIONS: A scalloped implant-abutment connection seems to be associated with higher peri-implant marginal bone loss compared to a flat implant-abutment connection. Therefore, the hypothesis of the present systematic review must...

  4. Imaging of common breast implants and implant-related complications: A pictorial essay.

    Science.gov (United States)

    Shah, Amisha T; Jankharia, Bijal B

    2016-01-01

    The number of women undergoing breast implant procedures is increasing exponentially. It is, therefore, imperative for a radiologist to be familiar with the normal and abnormal imaging appearances of common breast implants. Diagnostic imaging studies such as mammography, ultrasonography, and magnetic resonance imaging are used to evaluate implant integrity, detect abnormalities of the implant and its surrounding capsule, and detect breast conditions unrelated to implants. Magnetic resonance imaging of silicone breast implants, with its high sensitivity and specificity for detecting implant rupture, is the most reliable modality to asses implant integrity. Whichever imaging modality is used, the overall aim of imaging breast implants is to provide the pertinent information about implant integrity, detect implant failures, and to detect breast conditions unrelated to the implants, such as cancer.

  5. Prevalence of sinus floor elevation procedures and survival rates of implants placed in the posterior maxilla

    Directory of Open Access Journals (Sweden)

    Ceyda Ozçakır Tomruk

    2016-01-01

    Full Text Available The aim of this study was to assess the prevalence of sinus-lifting procedures and survival rates of implants placed in the posterior maxilla. This retrospective chart review examined consecutive patients with tooth/teeth loss in the posterior maxilla between 2008 and 2012 treated with sinus lift, when needed, and implant insertion. Demographic variables, health status, residual alveolar bone height, augmentation types, the implant position, diameter and height, and implant failure, prosthesis types, and the marginal bone loss were recorded. The study included 302 patients at a mean age of 5.2 years, who received a total of 609 dental implants. A total of 380 (62.3% implants were inserted in native areas, 203 (33.3% ones in external sinus-lifted areas and 26 (4.4% ones in internal lifted areas. The survival rate in native or internal lifted areas were 100% and 95.6% in external sinus lifted ones (10 implant failures/203 implants. Almost half of the implants were examined radiologically with a mean duration of 30 months and the mean marginal bone loss was 0.64 ± 1.2 mm. The results showed that the survival rates of native bone and the internal sinus lifting were slightly higher than that of external sinus lifting. Implants placed with sinus augmentation exhibited more marginal bone loss than implants in native bone.

  6. Immediate Direct-To-Implant Breast Reconstruction Using Anatomical Implants

    Directory of Open Access Journals (Sweden)

    Sung-Eun Kim

    2014-09-01

    Full Text Available BackgroundIn 2012, a new anatomic breast implant of form-stable silicone gel was introduced onto the Korean market. The intended use of this implant is in the area of aesthetic breast surgery, and many reports are promising. Thus far, however, there have been no reports on the use of this implant for breast reconstruction in Korea. We used this breast implant in breast reconstruction surgery and report our early experience.MethodsFrom November 2012 to April 2013, the Natrelle Style 410 form-stable anatomically shaped cohesive silicone gel-filled breast implant was used in 31 breasts of 30 patients for implant breast reconstruction with an acellular dermal matrix. Patients were treated with skin-sparing mastectomies followed by immediate breast reconstruction.ResultsThe mean breast resection volume was 240 mL (range, 83-540 mL. The mean size of the breast implants was 217 mL (range, 125-395 mL. Breast shape outcomes were considered acceptable. Infection and skin thinning occurred in one patient each, and hematoma and seroma did not occur. Three cases of wound dehiscence occurred, one requiring surgical intervention, while the others healed with conservative treatment in one month. Rippling did not occur. So far, complications such as capsular contracture and malrotation of breast implant have not yet arisen.ConclusionsBy using anatomic breast implants in breast reconstruction, we achieved satisfactory results with aesthetics better than those obtained with round breast implants. Therefore, we concluded that the anatomical implant is suitable for breast reconstruction.

  7. Retrospective analysis of 56 edentulous dental arches restored with 344 single-stage implants using an immediate loading fixed provisional protocol: statistical predictors of implant failure.

    Science.gov (United States)

    Kinsel, Richard P; Liss, Mindy

    2007-01-01

    The purpose of this retrospective study was to evaluate the effects of implant dimensions, surface treatment, location in the dental arch, numbers of supporting implant abutments, surgical technique, and generally recognized risk factors on the survival of a series of single-stage Straumann dental implants placed into edentulous arches using an immediate loading protocol. Each patient received between 4 and 18 implants in one or both dental arches. Periapical radiographs were obtained over a 2- to 10-year follow-up period to evaluate crestal bone loss following insertion of the definitive metal-ceramic fixed prostheses. Univariate tests for failure rates as a function of age ( or = 60 years), gender, smoking, bone grafting, dental arch, surface type, anterior versus posterior, number of implants per arch, and surgical technique were made using Fisher exact tests. The Cochran-Armitage test for trend was used to evaluate the presence of a linear trend in failure rates regarding implant length and implant diameter. Logistic regression modeling was used to determine which, if any, of the aforementioned factors would predict patient and implant failure. A significance criterion of P = .05 was utilized. Data were collected for 344 single-stage implants placed into 56 edentulous arches (39 maxillae and 17 mandibles) of 43 patients and immediately loaded with a 1-piece provisional fixed prosthesis. A total of 16 implants failed to successfully integrate, for a survival rate of 95.3%. Increased rates of failure were associated with reduced implant length, placement in the posterior region of the jaw, increased implant diameter, and surface treatment. Implant length emerged as the sole significant predictor of implant failure. In this retrospective analysis of 56 consecutively treated edentulous arches with multiple single-stage dental implants loaded immediately, reduced implant length was the sole significant predictor of failure.

  8. Cochlear implantation for single-sided deafness and tinnitus suppression.

    Science.gov (United States)

    Holder, Jourdan T; O'Connell, Brendan; Hedley-Williams, Andrea; Wanna, George

    To quantify the potential effectiveness of cochlear implantation for tinnitus suppression in patients with single-sided deafness using the Tinnitus Handicap Inventory. The study included 12 patients with unilateral tinnitus who were undergoing cochlear implantation for single-sided deafness. The Tinnitus Handicap Inventory was administered at the patient's cochlear implant candidacy evaluation appointment prior to implantation and every cochlear implant follow-up appointment, except activation, following implantation. Patient demographics and speech recognition scores were also retrospectively recorded using the electronic medical record. A significant reduction was found when comparing Tinnitus Handicap Inventory score preoperatively (61.2±27.5) to the Tinnitus Handicap Inventory score after three months of cochlear implant use (24.6±28.2, p=0.004) and the Tinnitus Handicap Inventory score beyond 6months of CI use (13.3±18.9, p=0.008). Further, 45% of patients reported total tinnitus suppression. Mean CNC word recognition score improved from 2.9% (SD 9.4) pre-operatively to 40.8% (SD 31.7) by 6months post-activation, which was significantly improved from pre-operative scores (p=0.008). The present data is in agreement with previously published studies that have shown an improvement in tinnitus following cochlear implantation for the large majority of patients with single-sided deafness. Copyright © 2017 Elsevier Inc. All rights reserved.

  9. Los implantes MG-OSSEOUS: Estudio multicéntrico retrospectivo MG-OSSEOUS implants: A multicentric retrospective study

    Directory of Open Access Journals (Sweden)

    E. Serrano Caturla

    2006-12-01

    commercial implants. Material and methodology. This is a retrospective multicentric study coordinated by a company called Scientific Management in O&SS (Barcelona, Spain. 1001 dental implants were placed in 247 patients and 328 prostheses were designed between 2004 and 2005, with a follow-up of two years. All implants were loaded with prostheses. We detail and analyze each implant, according to the diameter, length, position, surgical timing, loadings, design and types of prostheses and complementary surgical procedures, either synchronic or metachronic. Results. After the statistical method was homogenized, we were able to report an overall implant survival rate of 97.8% with monitoring of two years. The failures depending on the peculiarities of each clinical case are provided. No prosthetic failures are reported. Discussion. The criteria and indications applied by the professionals to the MG-OSSEOUS implants are standardized depending on the clinical case. Our results are compared with the international scientific literature, past and present, with these procedures totally agreeing with those found in the history of implantology. Finally, our survey is compared with those published by the Branemark team. Conclusion. The mixture between the quality of the MGOSSEOUS implants and the scientifically supported criteria regarding the implants, reveals an implant failure of 2.2% over two years, with a survival of 100% of both the replaced implants and the loaded prostheses.

  10. Scintigraphic examinations after stent implantation in central airways; Szintigraphische Untersuchungen bei Stents in den zentralen Atemwegen

    Energy Technology Data Exchange (ETDEWEB)

    Richter, W.S.; Kettner, B.I.; Munz, D.L. [Klinik und Poliklinik fuer Nuklearmedizin, Universitaetsklinikum Charite, Medizinische Fakulteat der Humboldt-Univ. zu Berlin (Germany)

    1998-03-01

    Endotracheal and endobronchial stent implantation has been developed as an effective treatment of benign and malignant airway stenosis and of tracheo- or bronchoesophageal fistulas. The selection of the stent type depends on the kind and site of disease. Chest X-ray and bronchoscopy are the procedures of choice for monitoring of stent position, structure, and function. However, with scintigraphic methods the effects of stent implantation on pulmonary ventilation and perfusion can be assessed non-invasively. The validation of the effect of a stent implantation on mucociliary and tussive clearance remains to be elucidated. (orig.) [Deutsch] Die endotracheale und -bronchiale Stentimplantation wurde in den letzten Jahren als effektive Massnahme bei benignen und malignen Stenosen der Atemwege, drohendem Atemwegsverschluss und bei tracheo- bzw. bronchooesophagealen Fisteln eingefuehrt. Der gewaehlte Stenttyp richtet sich nach dem Implantationsort und den krankheitsbedingten Veraenderungen. Zum Monitoring von Lage, Struktur und Funktion eines Stents dienen Thoraxroentgenaufnahmen und die Bronchoskopie. Nuklearmedizinische Verfahren koennen nicht-invasiv den Effekt der Stenteinlage auf Lungenventilation und -perfusion belegen. Die Validierung des Effekts einer Stentimplantation auf die mukoziliaere und tussive Clearance steht noch aus. (orig.)

  11. Residual neural processng of musical sound features in adult cochlear implant users

    DEFF Research Database (Denmark)

    Timm, Lydia; Vuust, Peter; Brattico, Elvira

    2014-01-01

    setting lasting only 20 min. The presentation of stimuli did not require the participants' attention, allowing the study of the early automatic stage of feature processing in the auditory cortex. For the CI users, we obtained mismatch negativity (MMN) brain responses to five feature changes...... neural skills for music processing even in CI users who have been implanted in adolescence or adulthood. HIGHLIGHTS: -Automatic brain responses to musical feature changes reflect the limitations of central auditory processing in adult Cochlear Implant users.-The brains of adult CI users automatically...

  12. Prevalence of Dental Implants and Evaluation of Peri-implant Bone Levels in Patients Presenting to a Dental School: A Radiographic Cross-Sectional 2-Year Study.

    Science.gov (United States)

    Alkan, Eylem Ayhan; Mau, Lian Ping; Schoolfield, John; Guest, Gary F; Cochran, David L

    To evaluate the number of patients with dental implants who present to a dental school clinic for screening and to report the prevalence of peri-implant bone level change detected on digital panoramic radiographs of those subjects. Patient screening files for 9,422 patients over a 2-year period were examined to see how many patients presented with dental implants. Those patients with at least one implant were further evaluated by measuring the bone level on the mesial and distal sides of the implant using the screening radiograph. A total of 187 patients (2%) had at least one implant. In regard to implants, 423 were examined and 146 (33%) had no detectable bone loss defined as bone level below the top of the implant. When thresholds of bone loss were evaluated, 109 implants (25%) had ≥ 2 mm of bone loss on either the mesial or distal sides or both. The median bone loss was 1.74 mm for the 277 implants with detectable bone loss and 2.97 mm for the 109 implants that had ≥ 2 mm bone loss. Interestingly, patients who were ≥ 70 years of age had significantly (P = .03) more bone loss in the mandible compared with the maxilla, while patients who were 60 to 69 years of age had significantly greater loss in the maxilla. These data reveal that for patients presenting to the dental school for a screening over a 2-year period, 1.98% had one or more dental implants. Furthermore, those patients with implants had a minimum amount of bone loss as measured from the top of the implant.

  13. Implants in free fibula flap supporting dental rehabilitation - Implant and peri-implant related outcomes of a randomized clinical trial.

    Science.gov (United States)

    Kumar, Vinay V; Ebenezer, Supriya; Kämmerer, Peer W; Jacob, P C; Kuriakose, Moni A; Hedne, Naveen; Wagner, Wilfried; Al-Nawas, Bilal

    2016-11-01

    The objective of this study was to assess the difference in success rates of implants when using two or four implant-supported-overdentures following segmental mandibular reconstruction with fibula free flap. This prospective, parallel designed, randomized clinical study was conducted with 1:1 ratio. At baseline, all participants already had segmental reconstruction of mandible with free fibula flap. The participants were randomized into two groups: Group-I received implant-supported-overdentures on two tissue-level implants and Group-II received implant-supported-overdentures on four tissue-level implants. Success rates of the implants were evaluated at 3 months, 6 months and 12 months following implant loading using marginal bone level changes as well as peri-implant indices (Buser et al., 1990). 52 patients were randomized into two treatment groups (26 each), out of which 18 patients (36 implants) of Group-I and 17 patients (68 implants) of Group-II were evaluated. One implant in Group-I was lost due to infective complications and one patient in the same group had superior barrel necrosis. There was a statistically significant increase at both time points (p = 0.03, p = 0.04 at 6 months, 12 months) in the amount of marginal bone loss in Group-I (0.4 mm, 0.5 mm at 6 months, 12 months) as compared to Group-II (0.1 mm, 0.2 mm at 6 months, 12 months). There were no clinically significant changes peri-implant parameters between both groups. Peri-implant soft tissue hyperplasia was seen in both groups, 32% of implants at 3-months, 26% at 6-months and 3% at 12-months follow-up. The results of this study show that patients with 2-implant-supported-overdentures had higher marginal bone loss as compared to patients with 4-implant-supported-overdentures. There were no clinically significant differences in peri-implant soft tissue factors in patients with 2- or 4-implant-supported-overdentures. Hyperplastic peri-implant tissues are common in the early implant

  14. Implantation rate effects on microstructure

    International Nuclear Information System (INIS)

    Choyke, W.J.; Spitznagel, J.A.; Wood, S.; Doyle, N.J.

    1981-01-01

    We report a detailed TEM study of rate effects in a metal (304 SS) where we dope with an insoluble atom (He) and create the displacement damage with high energy Si. The rates of doping and the rates of producing lattice damage are independently varied during dual implantation. In addition to varying the doping rates of the He the magnitude of the displacement damage prior to He implantation is also varied (beam history). We find that the beam history has virtually no effect on maximum bubble size but it has a major effect on the average cavity diameter. A weak dependence of cavity number density on helium implantation rate is found. The total dislocation density is relatively independent of the doping rate and beam history at 550 and 700 0 C, whereas the loop fraction is sensitive to beam history at these temperatures. Acicular precipitate formation is weakly dependent on doping, doping rate and more strongly dependent on doping concentration and temperature. This form of solute segregation is very sensitive to beam history. (orig.)

  15. Imaging of common breast implants and implant-related complications: A pictorial essay

    Directory of Open Access Journals (Sweden)

    Amisha T Shah

    2016-01-01

    Full Text Available The number of women undergoing breast implant procedures is increasing exponentially. It is, therefore, imperative for a radiologist to be familiar with the normal and abnormal imaging appearances of common breast implants. Diagnostic imaging studies such as mammography, ultrasonography, and magnetic resonance imaging are used to evaluate implant integrity, detect abnormalities of the implant and its surrounding capsule, and detect breast conditions unrelated to implants. Magnetic resonance imaging of silicone breast implants, with its high sensitivity and specificity for detecting implant rupture, is the most reliable modality to asses implant integrity. Whichever imaging modality is used, the overall aim of imaging breast implants is to provide the pertinent information about implant integrity, detect implant failures, and to detect breast conditions unrelated to the implants, such as cancer.

  16. Retinal images in the human eye with implanted intraocular lens

    Science.gov (United States)

    Zając, Marek; Siedlecki, Damian; Nowak, Jerzy

    2007-04-01

    A typical proceeding in cataract is based on the removal of opaque crystalline lens and inserting in its place the artificial intraocular lens (IOL). The quality of retinal image after such procedure depends, among others, on the parameters of the IOL, so the design of the implanted lens is of great importance. An appropriate choice of the IOL material, especially in relation to its biocompatibility, is often considered. However the parameter, which is often omitted during the IOL design is its chromatic aberration. In particular lack of its adequacy to the chromatic aberration of a crystalline lens may cause problems. In order to fit better chromatic aberration of the eye with implanted IOL to that of the healthy eye we propose a hybrid - refractive-diffractive IOL. It can be designed in such way that the total longitudinal chromatic aberration of an eye with implanted IOL equals the total longitudinal chromatic aberration of a healthy eye. In this study we compare the retinal image quality calculated numerically on the basis of the well known Liou-Brennan eye model with typical IOL implanted with that obtained if the IOL is done as hybrid (refractive-diffractive) design.

  17. Interaction of tinnitus suppression and hearing ability after cochlear implantation.

    Science.gov (United States)

    Wang, Qian; Li, Jia-Nan; Lei, Guan-Xiong; Chen, Dai-Shi; Wang, Wei-Ze; Chen, Ai-Ting; Mong, Meng-Di; Li, Sun; Jiao, Qing-Shan; Yang, Shi-Ming

    2017-10-01

    To study the postoperative impact of cochlear implants (CIs) on tinnitus, as well as the impact of tinnitus on speech recognition with CI switched on. Fifty-two postlingual deafened CI recipients (21 males and 31 females) were assessed using an established Tinnitus Characteristics Questionnaire and Tinnitus Handicap Inventory (THI) before and after cochlear implantation. The tinnitus loudness was investigated when CI was switched on and off in CI recipients with persistent tinnitus. The relation between tinnitus loudness and recipients' satisfaction of cochlear implantation was analyzed by the visual analogue scale (VAS) score. With CI 'OFF', 42 CI recipients experienced tinnitus postimplant ipsilaterally and 44 contralaterally. Tinnitus was totally suppressed ipsilateral to the CI with CI 'ON' in 42.9%, partially suppressed in 42.9%, unchanged in 11.9% and aggravated in 2.4%. Tinnitus was totally suppressed contralaterally with CI 'ON' in 31.8% of CI recipients, partially suppressed in 47.7%, unchanged in 20.5%. Pearson correlation analysis showed that tinnitus loudness and the results of cochlear implant patients satisfaction was negatively correlated (r = .674, p tinnitus. The tinnitus loudness may affect patients' satisfaction with the use of CI.

  18. [Ceramic-on-ceramic bearings in total hip arthroplasty (THA)].

    Science.gov (United States)

    Sentürk, U; Perka, C

    2015-04-01

    The main reason for total hip arthroplasty (THA) revision is the wear-related aseptic loosening. Younger and active patients after total joint replacement create high demands, in particular, on the bearings. The progress, especially for alumina ceramic-on-ceramic bearings and mixed ceramics have solved many problems of the past and lead to good in vitro results. Modern ceramics (alumina or mixed ceramics containing alumina) are extremely hard, scratch-resistant, biocompatible, offer a low coefficient of friction, superior lubrication and have the lowest wear rates in comparison to all other bearings in THA. The disadvantage of ceramic is the risk of material failure, i.e., of ceramic fracture. The new generation of mixed ceramics (delta ceramic), has reduced the risk of head fractures to 0.03-0.05 %, but the risk for liner fractures remains unchanged at about 0.02 %. Assuming a non-impinging component implantation, ceramic-on-ceramic bearings have substantial advantages over all other bearings in THA. Due to the superior hardness, ceramic bearings produce less third body wear and are virtually impervious to damage from instruments during the implantation process. A specific complication for ceramic-on-ceramic bearings is "squeaking". The high rate of reported squeaking (0.45 to 10.7 %) highlights the importance of precise implant positioning and the stem and patient selection. With precise implant positioning this problem is rare with many implant designs and without clinical relevance. The improved tribology and the presumable resulting implant longevity make ceramic-on-ceramic the bearing of choice for young and active patients. Georg Thieme Verlag KG Stuttgart · New York.

  19. Retrograde peri-implantitis

    Directory of Open Access Journals (Sweden)

    Mohamed Jumshad

    2010-01-01

    Full Text Available Retrograde peri-implantitis constitutes an important cause for implant failure. Retrograde peri-implantitis may sometimes prove difficult to identify and hence institution of early treatment may not be possible. This paper presents a report of four cases of (the implant placed developing to retrograde peri-implantitis. Three of these implants were successfully restored to their fully functional state while one was lost due to extensive damage. The paper highlights the importance of recognizing the etiopathogenic mechanisms, preoperative assessment, and a strong postoperative maintenance protocol to avoid retrograde peri-implant inflammation.

  20. 21 CFR 872.3940 - Total temporomandibular joint prosthesis.

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3940 Total temporomandibular joint... implanted in the human jaw to replace the mandibular condyle and augment the glenoid fossa to functionally...

  1. Comparison of optical quality after implantable collamer lens implantation and wavefront-guided laser in situ keratomileusis.

    Science.gov (United States)

    Liu, Hong-Ting; Zhou, Zhou; Luo, Wu-Qiang; He, Wen-Jing; Agbedia, Owhofasa; Wang, Jiang-Xia; Huang, Jian-Zhong; Gao, Xin; Kong, Min; Li, Min; Li, Li

    2018-01-01

    To compare the optical quality after implantation of implantable collamer lens (ICL) and wavefront-guided laser in situ keratomileusis (WG-LASIK). The study included 40 eyes of 22 patients with myopia who accepted ICL implantation and 40 eyes of 20 patients with myopia who received WG-LASIK. Before surgery and three months after surgery, the objective scattering index (OSI), the values of modulation transfer function (MTF) cutoff frequency, Strehl ratio, and the Optical Quality Analysis System (OQAS) values (OVs) were accessed. The higher order aberrations (HOAs) data including coma, trefoil, spherical, 2 nd astigmatism and tetrafoil were also obtained. For patients with pupil size LASIK group, significant improvements in visual acuities were found postoperatively, with a significant reduction in spherical equivalent ( P LASIK group, the OSI significantly increased from 0.68±0.43 preoperatively to 0.91±0.53 postoperatively (Wilcoxon signed ranks test, P =0.000). None of the mean MTF cutoff frequency, Strehl ratio, OVs showed statistically significant changes in both ICL and WG-LASIK groups. In the ICL group, there were no statistical differences in the total HOAs for either 4 mm-pupil or 6 mm-pupil. In the WG-LASIK group, the HOA parameters increased significantly at 4 mm-pupil. The total ocular HOAs, coma, spherical and 2 nd astigmatism were 0.12±0.06, 0.06±0.03, 0.00±0.03, 0.02±0.01, respectively. After the operation, these values were increased into 0.16±0.07, 0.08±0.05, -0.04±0.04, 0.03±0.01 respectively (Wilcoxon signed ranks test, all P LASIK group. ICL implantation has a less disturbance to optical quality than WG-LASIK. The OQAS is a valuable complementary measurement to the wavefront aberrometers in evaluating the optical quality.

  2. Multichannel cochlear implantation in the scala vestibuli.

    Science.gov (United States)

    Lin, Karen; Marrinan, Michelle S; Waltzman, Susan B; Roland, J Thomas

    2006-08-01

    Sensorineural hearing loss resulting from otosclerosis, meningitis, chronic otitis media, autoimmune ear disease, and trauma can be associated with partial or total obstruction of the cochlear scalae. Multichannel cochlear implantation may be difficult in a cochlea with an obstructed scala tympani. The purpose of this study is to determine the safety and efficacy of scala tympani electrode insertion. Retrospective chart review. Academic medical center. Eight children and adults with profound sensorineural hearing loss who underwent cochlear implantation with known scala vestibuli electrode array insertion were subjects for this study. Eight study subjects underwent implantation: five with the Nucleus 24RCS (Contour) device and three with the Nucleus 24M device. Imaging findings, operative findings, and age-appropriate speech perception testing. All patients had full electrode insertion. Various obstructive patterns on computed tomography and magnetic resonance imaging were found, and there was a range of speech perception results. All but one patient improved based on age-appropriate monosyllabic word and sentence tests. Scala vestibuli multielectrode insertion is a viable alternative when scala tympani insertion is not possible because of abnormal anatomy or anatomical changes secondary to disease or previous implantation. We will also present an algorithm of options for decision making for implantation when encountering cochlear obstruction and difficult electrode insertion.

  3. Apical root resorption in maxillary incisors when employing micro-implant and J-hook headgear anchorage: a 4-month radiographic study.

    Science.gov (United States)

    Wang, Qingzhu; Chen, Wenjing; Smales, Roger J; Peng, Hui; Hu, Xiaokun; Yin, Lu

    2012-10-01

    This study evaluated, over a 4-month study period, the amount of apical root resorption occurring in maxillary central incisors following their retraction when employing either micro-implant or J-hook headgear anchorage. The prospective randomised clinical trial was conducted in Orthodontic Clinic, College of Stomatology, China from 2008-2009. Subjects are patients requiring fixed appliances on waiting list (n=20). In female Han Chinese patients aged from 16-26 years, standardized periapical radiographs from 10 randomly assigned patients with maxillary protrusions comprising the micro-implant group, and from 10 similar patients comprising the J-hook headgear group, were assessed for maxillary central incisor apical root resorption. Measurements before and after orthodontic therapy were also obtained from lateral cephalometric radiographs to calculate incisor horizontal retraction and vertical intrusion distances. Estimated retraction force vectors were calculated in horizontal and vertical directions for both treatment groups. Data analysis employed t-tests and the Pearson correlation test, with α=0.05 for statistical significance. The results showed that when compared with the J-hook group, significantly more apical root resorption shortening of the maxillary central incisors was observed in the micro-implant group (1.27 mm difference, 95% CI=0.70-1.84, Pmicro-implant group resulted in significantly more apical root resorption shortening and maxillary central incisor retraction than when intermittent J-hook retraction was employed. The employment of continuous duration orthodontic forces presents a risk for increased apical root resorption that requires careful radiographic monitoring.

  4. Long-term results of uncemented alumina acetabular implants.

    Science.gov (United States)

    Boehler, M; Knahr, K; Plenk, H; Walter, A; Salzer, M; Schreiber, V

    1994-01-01

    We report the clinical and tribological performance of 67 ceramic acetabular prostheses implanted between 1976 and 1979 without bone cement. They articulated with ceramic femoral heads mounted on mental femoral stems. After a mean elapsed period of 144 months, 59 sockets were radiographically stable but two showed early signs and six showed late signs of loosening. Four of the loose sockets have been revised. Histological analysis of the retrieved tissue showed a fibrous membrane around all the implants, with fibrocartilage in some. There was no bone ingrowth, and the fibrous membrane was up to 6 mm thick and infiltrated with lymphocytes, plasma cells, and macrophages. Intra- and extracellular birefringent wear particles were seen. Tribological analysis showed total wear rates in two retrieved alumina-on-alumina joints of 2.6 microns per year in a stable implant and 68 microns in a loose implant. Survival analysis showed a revision rate of 12.4% at 136 months.

  5. Interface strength of SiC/SiC composites with and without helium implantation using micro-indentation test

    International Nuclear Information System (INIS)

    Saito, M.; Ohtsuka, S.

    1998-01-01

    Helium implantation effects on interface strength of SiC/SiC composite were studied using the micro-indentation fiber push-out method. Helium implantation was carried out with an accelerator at about 400 K. Total amount of implanted helium was approximately 10000 appm. Increase of the fiber push-in load was observed in as-implanted specimen. After post-implantation-annealing at 1673 K for 1 h, the change of the fiber push-in load by helium implantation was not observed. Effects of helium implantation on the interface are discussed. (orig.)

  6. Integrated versus non-integrated orbital implants for treating anophthalmic sockets.

    Science.gov (United States)

    Schellini, Silvana; El Dib, Regina; Silva, Leandro Re; Farat, Joyce G; Zhang, Yuqing; Jorge, Eliane C

    2016-11-07

    Anophthalmia is the absence of one or both eyes, and it can be congenital (i.e. a birth defect) or acquired later in life. There are two main types of orbital implant: integrated, whereby the implant receives a blood supply from the body that allows for the integration of the prosthesis within the tissue; and non-integrated, where the implant remains separate. Despite the remarkable progress in anophthalmic socket reconstruction and in the development of various types of implants, there are still uncertainties about the real roles of integrated (hydroxyapatite (HA), porous polyethylene (PP), composites) and non-integrated (polymethylmethacrylate (PMMA)/acrylic and silicone) orbital implants in anophthalmic socket treatment. To assess the effects of integrated versus non-integrated orbital implants for treating anophthalmic sockets. We searched CENTRAL (which contains the Cochrane Eyes and Vision Trials Register) (2016, Issue 7), Ovid MEDLINE, Ovid MEDLINE In-Process and Other Non-Indexed Citations, Ovid MEDLINE Daily, Ovid OLDMEDLINE (January 1946 to August 2016), Embase (January 1980 to August 2016), Latin American and Caribbean Health Sciences Literature Database (LILACS) (1982 to August 2016), the ISRCTN registry (www.isrctn.com/editAdvancedSearch), ClinicalTrials.gov (www.clinicaltrials.gov), and the World Health Organization (WHO) International Clinical Trials Registry Platform (ICTRP) (www.who.int/ictrp/search/en). We did not use any date or language restrictions in the electronic searches for trials. We last searched the electronic databases on 8 August 2016. Randomised controlled trials (RCTs) and quasi-RCTs of integrated and non-integrated orbital implants for treating anophthalmic sockets. Two authors independently selected relevant trials, assessed methodological quality and extracted data. We included three studies with a total of 284 participants (250 included in analysis). The studies were conducted in India, Iran and the Netherlands. The three

  7. Loss of I-125 seeds after perineal implantation of the prostate

    International Nuclear Information System (INIS)

    Wopereis, A.J.M.; Moerland, M.A.; Koning, J.H.A.G. de; Battermann, J.J.

    1996-01-01

    Introduction: One of the treatment modalities of early stage prostate cancer is the permanent implantation of I-125 seeds. The aim of this study was to obtain insight in the loss of seeds after implantation. Methods and Materials: During the past 6 years, 100 patients were treated and examined. Radiographs of the prostate area were taken at discharge (after 2 or 3 days) and combined with a follow-up appointment, successively after 1, 3, 6, 12 and 24 months. 10 patients were excluded from this study because of a later performed prostatectomy or TURP. During the hospitalisation period the patient's excrements were examined for lost seeds. Furthermore patients were instructed to urinate through a tea-strainer in the first month following implantation in order to prevent seeds from entering the sewage system. Results: We observed an overall loss of 5% during the entire follow-up period of 2 years. Further analysis of the obtained data showed that most of the seeds (3% of the implanted seeds) were lost in the first 2 days after implantation. Due to special attention paid to safety measures, 94% of the lost seeds were retrieved during the admission period. Because of adequate instructions given to the patients, 70% of the seeds lost during the first month after discharge (0.5% of the total number of remaining implanted seeds) were also retrieved. Losing seeds during the first month after implantation did not increase the chance of further loss later on. A total of 13 seeds (in all patients) was lost after 1 month (of which 6 were lost after more then one year and are for radiation safety reasons not of importance). Conclusions: Most seeds are lost during the first days after implantation. Therefore, radiographs are indicated at discharge, after 1 month (for evaluation of safety precautions) and after 1 year as a conclusion to the treatment

  8. Repositioning of malpositioned or flipped central venous catheters

    Energy Technology Data Exchange (ETDEWEB)

    Thalhammer, A.; Jacobi, V.; Balzer, J.; Vogl, T.J. [Institute for Diagnostic and Interventional Radiology, Central Radiology Clinic, J.W. Goethe University, Frankfurt am Main (Germany)

    2002-03-01

    Primary misplaced or secondary flipped implanted catheters are located mostly in the right jugular vein. We demonstrate an effective method to replace fix implanted catheters such as Ports, Grochomg or Hickman catheters. Using a femoral venous approach, replacement into the superior vena cava can easily be done with a Sidewinder 1 catheter which is hooked over the misplaced central venous approach. In all our patients the method was successful. The repositioning technique described is simple, fast and has low costs. We can keep sterile conditions and do not need to solve the catheters' fixation. (orig.)

  9. Total joint Perioperative Surgical Home: an observational financial review.

    Science.gov (United States)

    Raphael, Darren R; Cannesson, Maxime; Schwarzkopf, Ran; Garson, Leslie M; Vakharia, Shermeen B; Gupta, Ranjan; Kain, Zeev N

    2014-01-01

    The numbers of people requiring total arthroplasty is expected to increase substantially over the next two decades. However, increasing costs and new payment models in the USA have created a sustainability gap. Ad hoc interventions have reported marginal cost reduction, but it has become clear that sustainability lies only in complete restructuring of care delivery. The Perioperative Surgical Home (PSH) model, a patient-centered and physician-led multidisciplinary system of coordinated care, was implemented at UC Irvine Health in 2012 for patients undergoing primary elective total knee arthroplasty (TKA) or total hip arthroplasty (THA). This observational study examines the costs associated with this initiative. The direct cost of materials and services (excluding professional fees and implants) for a random index sample following the Total Joint-PSH pathway was used to calculate per diem cost. Cost of orthopedic implants was calculated based on audit-verified direct cost data. Operating room and post-anesthesia care unit time-based costs were calculated for each case and analyzed for variation. Benchmark cost data were obtained from literature search. Data are presented as mean ± SD (coefficient of variation) where possible. Total per diem cost was $10,042 ± 1,305 (13%) for TKA and $9,952 ± 1,294 (13%) for THA. Literature-reported benchmark per diem cost was $17,588 for TKA and $16,267 for THA. Implant cost was $7,482 ± 4,050 (54%) for TKA and $9869 ± 1,549 (16%) for THA. Total hospital cost was $17,894 ± 4,270 (24%) for TKA and $20,281 ± 2,057 (10%) for THA. In-room to incision time cost was $1,263 ± 100 (8%) for TKA and $1,341 ± 145 (11%) for THA. Surgery time cost was $1,558 ± 290 (19%) for TKA and $1,930 ± 374 (19%) for THA. Post-anesthesia care unit time cost was $507 ± 187 (36%) for TKA and $557 ± 302 (54%) for THA. Direct hospital costs were driven substantially below USA benchmark levels using the Total Joint-PSH pathway. The incremental

  10. Cochlear implants in children implanted in Jordan: A parental overview.

    Science.gov (United States)

    Alkhamra, Rana A

    2015-07-01

    Exploring the perspective of parents on the cochlear implant process in Jordan. Sixty parents of deaf children were surveyed on the information gathering process prior to cochlear implant surgery, and their implant outcome expectations post-surgery. Whether child or parent characteristics may impact parents' post-surgical expectations was explored. Although parents used a variety of information sources when considering a cochlear implant, the ear, nose and throat doctor comprised their major source of information (60%). Parents received a range of information prior to cochlear implant but agreed (93.3%) on the need for a multidisciplinary team approach. Post-surgically, parents' expected major developments in the areas of spoken language (97%), and auditory skills (100%). Receiving education in mainstream schools (92%) was expected too. Parents perceived the cochlear implant decision as the best decision they can make for their child (98.3%). A significant correlation was found between parents contentment with the cochlear implant decision and expecting developments in the area of reading and writing (r=0.7). Child's age at implantation and age at hearing loss diagnosis significantly affected parents' post-implant outcome expectations (pparents agree on the need for a comprehensive multidisciplinary team approach during the different stages of the cochlear implant process. Parents' education about cochlear implants prior to the surgery can affect their post-surgical outcome expectations. The parental perspective presented in this study can help professionals develop better understanding of parents' needs and expectations and henceforth improve their services and support during the different stages of the cochlear implant process. Copyright © 2015. Published by Elsevier Ireland Ltd.

  11. Do Breast Implants Influence Breastfeeding? A Meta-Analysis of Comparative Studies.

    Science.gov (United States)

    Cheng, Fengrui; Dai, Shuiping; Wang, Chiyi; Zeng, Shaoxue; Chen, Junjie; Cen, Ying

    2018-06-01

    Aesthetic breast implant augmentation surgery is the most popular plastic surgery worldwide. Many women choose to receive breast implants during their reproductive ages, although the long-term effects are still controversial. Research aim: We conducted a meta-analysis to assess the influence of aesthetic breast augmentation on breastfeeding. We also compared the exclusive breastfeeding rates of periareolar versus inframammary incision. A systematic search for comparative studies about breast implants and breastfeeding was performed in PubMed, MEDLINE, EMBASE, Cochrane Central Register of Controlled Trials, ScienceDirect, Scopus, and Web of Science through May 2018. Meta-analysis was conducted with a random-effects model (or fixed effects, if heterogeneity was absent). Four cohorts and one cross-sectional study were included. There was a significant reduction in the exclusive breastfeeding rate for women with breast implants compared with women without implants, pooled relative risk = 0.63, 95% confidence interval [0.46, 0.86], as well as the breastfeeding rate, pooled relative risk = 0.88, 95% confidence interval [0.81, 0.95]. There was no evidence that periareolar incision was associated with a reduction in the exclusive breastfeeding rate, pooled relative risk = 0.84, 95% confidence interval [0.45, 1.58]. Participants with breast implants are less likely to establish breastfeeding, especially exclusive breastfeeding. Periareolar incision does not appear to reduce the exclusive breastfeeding rate.

  12. Development and fabrication of patient-specific knee implant using additive manufacturing techniques

    Science.gov (United States)

    Zammit, Robert; Rochman, Arif

    2017-10-01

    Total knee replacement is the most effective treatment to relief pain and restore normal function in a diseased knee joint. The aim of this research was to develop a patient-specific knee implant which can be fabricated using additive manufacturing techniques and has reduced wear rates using a highly wear resistant materials. The proposed design was chosen based on implant requirements, such as reduction in wear rates as well as strong fixation. The patient-specific knee implant improves on conventional knee implants by modifying the articulating surfaces and bone-implant interfaces. Moreover, tribological tests of different polymeric wear couples were carried out to determine the optimal materials to use for the articulating surfaces. Finite element analysis was utilized to evaluate the stresses sustained by the proposed design. Finally, the patient-specific knee implant was successfully built using additive manufacturing techniques.

  13. Clinical and radiographic evaluation of early loaded narrow-diameter implants

    DEFF Research Database (Denmark)

    Maiorana, Carlo; King, Paul; Quaas, Sebastian

    2015-01-01

    OBJECTIVE: To evaluate the clinical reliability of narrow implants placed in a one-stage procedure and early loaded in the upper and lower incisor region. MATERIAL AND METHODS: This is a prospective, single-arm, multicenter study in which patients with missing natural dentition in upper lateral a...... be considered as a valid solution in the treatment of the localized narrow bony defects in the anterior area with reduced spaces between the natural teeth....... healing period. Clinical and radiographic checks were performed at implant placement, loading, and at the 6, 12, 24, and 36 months follow-up visits. RESULTS: A total of 69 subjects with 97 implants have been included in this study. From surgery to 36 months follow-up, 5.6% of the implants showed bone loss...... loss between loading and the 1-year follow-up visit (Galindo-Moreno et al. 2012). This finding, associated with a stable probing pocket depth and a stable crown-gingiva distance, using a one-stage surgical procedure helps to maintain the integrity of the peri-implant soft tissues. Narrow implants can...

  14. [Emotional response to music by postlingually-deafened adult cochlear implant users].

    Science.gov (United States)

    Wang, Shuo; Dong, Ruijuan; Zhou, Yun; Li, Jing; Qi, Beier; Liu, Bo

    2012-10-01

    To assess the emotional response to music by postlingually-deafened adult cochlear implant users. Munich music questionnaire (MUMU) was used to match the music experience and the motivation of use of music between 12 normal-hearing and 12 cochlear implant subjects. Emotion rating test in Musical Sounds in Cochlear Implants (MuSIC) test battery was used to assess the emotion perception ability for both normal-hearing and cochlear implant subjects. A total of 15 pieces of music phases were used. Responses were given by selecting the rating scales from 1 to 10. "1" represents "very sad" feeling, and "10" represents "very happy feeling. In comparison with normal-hearing subjects, 12 cochlear implant subjects made less active use of music for emotional purpose. The emotion ratings for cochlear implant subjects were similar to normal-hearing subjects, but with large variability. Post-lingually deafened cochlear implant subjects on average performed similarly in emotion rating tasks relative to normal-hearing subjects, but their active use of music for emotional purpose was obviously less than normal-hearing subjects.

  15. Long time follow up of implant therapy and treatment of peri-implantitis.

    Science.gov (United States)

    Roos-Jansåker, Ann-Marie

    2007-01-01

    Dental implants have become an often used alternative to replace missing teeth, resulting in an increasing percentage of the adult population with implant supported prosthesis. Although favourable long-term results of implant therapy have been reported, infections occur. Until recently few reports included data on peri-implant infections, possibly underestimating this complication of implant treatment. It is possible that some infections around implants develop slowly and that with time peri-implantitis will be a common complication to implant therapy as an increasing number of patients have had their implants for a long time (>10 years). Data on treatment of peri-implant lesions are scarce leaving the clinician with limited guidance regarding choice of treatment. The aim of this thesis was to study the frequency of implant loss and presence of peri-implant lesions in a group of patients supplied with Brånemark implants 9-14 years ago, and to relate these events to patient and site specific characteristics. Moreover three surgical treatment modalities for peri-implantitis were evaluated. The thesis is based on six studies; Studies I-III included 218 patients and 1057 implants followed for 9-14 years evaluating prevalence of, and factors related to implant loss (Paper I) and prevalence of peri-implant infections and related factors (Paper I-III). Study IV is a review describing different treatment modalities of peri-implant infections. Study V is a prospective cohort study involving 36 patients and 65 implants, evaluating the use of a bone substitute with or without the use of a resorbable membrane. Study VI is a case series with 12 patients and 16 implants, evaluating a bone substitute in combination with a resorbable membrane and submerged healing. This thesis demonstrated that: After 9-14 years the survival rates of dental implants are high (95.7%). Implant loss seems to cluster within patients and are related to periodontitis evidenced as bone loss on

  16. Hip Implant Systems

    Science.gov (United States)

    ... Implants and Prosthetics Metal-on-Metal Hip Implants Hip Implants Share Tweet Linkedin Pin it More sharing options Linkedin Pin it Email Print Hip implants are medical devices intended to restore mobility ...

  17. The Effect of Price on Surgeons' Choice of Implants: A Randomized Controlled Survey

    NARCIS (Netherlands)

    Wasterlain, Amy S.; Melamed, Eitan; Bello, Ricardo; Karia, Raj; Capo, John T.; Adams, Julie; Vochteloo, A. J. H.; Powell, Andrew John; Marcus, Alexander; Andreas, Platz; Miller, Anna N.; Berner, A. B. Arne; Altintas, Burak; Sears, Benjamin W.; Calfee, Ryan P.; Ekholm, Carl; Fernandes, C. H.; Porcellini, Giuseppe; Jones, Clifford; Moreno-Serrano, Constanza L.; Manke, Chad; Crist, Brett D.; Haverkamp, Daniel; Hanel, Doug; Merchant, Milind; Rikli, Daniel A.; Shafi, Mohamed; Patiño, Juan M.; Duncan, Scott F.; Ballas, Efsthathios G.; Harvey, Edward; Walbeehm, E. T.; Schumer, Evan D.; Evans, Peter J.; Suarez, Fabio; Lopez-Gonzalez, Francisco; Seibert, Franz Josef; DeSilva, Gregory; Bayne, Grant J.; Guitton, T. G.; Nancollas, Michael; Lane, Lewis B.; Westly, Stephen K.; Villamizar, Harold Alonso; Pountos, Ippokratis; Hofmeister, Eric; Biert, Jan; Goslings, J. Carel; Bishop, Julius; Peters, R. W.

    2017-01-01

    Surgical costs are under scrutiny and surgeons are being held increasingly responsible for cost containment. In some instances, implants are the largest component of total procedure cost, yet previous studies reveal that surgeons' knowledge of implant prices is poor. Our study aims to (1) understand

  18. Hearing improvement with softband and implanted bone-anchored hearing devices and modified implantation surgery in patients with bilateral microtia-atresia.

    Science.gov (United States)

    Wang, Yibei; Fan, Xinmiao; Wang, Pu; Fan, Yue; Chen, Xiaowei

    2018-01-01

    To evaluate auditory development and hearing improvement in patients with bilateral microtia-atresia using softband and implanted bone-anchored hearing devices and to modify the implantation surgery. The subjects were divided into two groups: the softband group (40 infants, 3 months to 2 years old, Ponto softband) and the implanted group (6 patients, 6-28 years old, Ponto). The Infant-Toddler Meaning Auditory Integration Scale was used conducted to evaluate auditory development at baseline and after 3, 6, 12, and 24 months, and visual reinforcement audiometry was used to assess the auditory threshold in the softband group. In the implanted group, bone-anchored hearing devices were implanted combined with the auricular reconstruction surgery, and high-resolution CT was used to assess the deformity preoperatively. Auditory threshold and speech discrimination scores of the patients with implants were measured under the unaided, softband, and implanted conditions. Total Infant-Toddler Meaning Auditory Integration Scale scores in the softband group improved significantly and approached normal levels. The average visual reinforcement audiometry values under the unaided and softband conditions were 76.75 ± 6.05 dB HL and 32.25 ± 6.20 dB HL (P hearing devices is effective for auditory development and hearing improvement in infants with bilateral microtia-atresia. Wearing softband bone-anchored hearing devices before auricle reconstruction and combining bone-anchored hearing device implantation with auricular reconstruction surgery may bethe optimal clinical choice for these patients, and results in more significant hearing improvement and minimal surgical and anesthetic injury. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. Usefullness of three-dimensional templating software to quantify the contact state between implant and femur in total hip arthroplasty.

    Science.gov (United States)

    Inoue, Daisuke; Kabata, Tamon; Maeda, Toru; Kajino, Yoshitomo; Fujita, Kenji; Hasegawa, Kazuhiro; Yamamoto, Takashi; Takagi, Tomoharu; Ohmori, Takaaki; Tsuchiya, Hiroyuki

    2015-12-01

    It would be ideal if surgeons could precisely confirm whether the planned femoral component achieves the best fit and fill of implant and femur. However, the cortico-cancellous interfaces can be difficult to standardize using plain radiography, and therefore, determining the contact state is a subjective decision by the examiner. Few reports have described the use of CT-based three-dimensional templating software to quantify the contact state of stem and femur in detail. The purpose of this study was to use three-dimensional templating software to quantify the implant-femur contact state and develop a technique to analyze the initial fixation pattern of a cementless femoral stem. We conducted a retrospective review of 55 hips in 53 patients using a short proximal fit-and-fill anatomical stem (APS Natural-Hip™ System). All femurs were examined by density mapping which can visualize and digitize the contact state. We evaluated the contact state of implant and femur by using density mapping. The varus group (cases that had changed varus 2° by 3 months after surgery) consisted of 11 hips. The varus group showed no significant difference with regard to cortical contact in the proximal medial portion (Gruen 7), but the contact area in the distal portion (Gruen 3 and Gruen 5) was significantly lower than that of non-varus group. Density mapping showed that the stem only has to be press-fit to the medial calcar, but also must fill the distal portion of the implant in order to achieve the ideal contact state. Our results indicated that quantifying the contact state of implant and femur by using density mapping is a useful technique to accurately analyze the fixation pattern of a cementless femoral stem.

  20. PLANNING OF IMPLANTO‐PROSTHETIC STRUCTURES IN TOTAL EDENTATION ACCORDING TO BIOMECHANICAL CRITERIA

    Directory of Open Access Journals (Sweden)

    N. VASILE

    2013-07-01

    Full Text Available Scope of the study: Analysis of the biomechanical aspects of the implanto‐prosthetic structures for planning the treatment in cases of total edentation.Materials and method: The study was performed in the Clinics of Prosthetics and Oral Implantology, Military Emergency Hospital of Sibiu, on a group of mandibularly totally edentated patients. Planning of the implanto‐pros‐ thetic treatment had in view the peculiarities of total man‐ dibular edentation and observance of the biomechanical principles. Selection of the type of occlusion restoration considered the presence of parafunctions and the nature of the antagonistic arch. Special attention was paid to the direction and intensity of the forces acting in the region of the future prosthetic work. When bruxism was manifested, its preimplantary removal was compulsory.Results and discussion: In fixed prosthetic restaurati‐ ons applied on implants, distribuition of forces obviously depend on the quality of osteo‐acceptance, as well, and also on the elasticity degree of the prosthetic work. In the case of mobilized prosthetic restorations supported on implants, rigidization of implants from the anterior region of the mandible may be obtained by means of a bar. In decreasing order of their elasticity, the materials employed are: acrylate, composites, noble and seminoble alloys, other metals, ceramics. Ceramics confers maximum stability to implants, yet without redeeming the forces. For amortizing the forces and for a progressive charging of the implants, it is recommended that the first (temporary prosthetic restorations should be made of either acrylate or compo‐ sites.Conclusions. Observance of the occlusological princi‐ ples in cases of occlusal reconstruction represents the determining element which assures the osteo‐acceptance of implants and the integrity of prosthetic restaurations.

  1. Sensitivity of the ureter to radiation before and after ureterojejuno-implantation

    International Nuclear Information System (INIS)

    Schenk, K.J.

    1981-01-01

    The investigation refers to dexhal ureterosigmoidostomies, carried out on 15 dogs. The implanted right ureters and the left ureters left in the bladders of 5 dogs were then treated with radiation of a total focal dose of 60 Gy. The investigation referred to the comparison of different ureter modalities and their sensibility to radiation in respect to statements on the various sorts of therapy strategies. The test animals which has been only operated on were killed 68 d.p.o at earliest and 295 d.p.o. The survival time of the 5 animals which has been operated on and irradiated was 156-269 d.p.o. and 22-59 d after the last irradiation, respectively. While the non-altered ureters remained without pathological findings, there were anastomotic stenoses with ascending infections of the upper urinary tract in 40% of the ureters only implanted into the sigma and another increase in the anastomotic stenoses (80%) was observed in the ureters which had been implanted and irradiated with a total focal dose of 60 Gy. It was also shown by means of X-ray method, macro and micropathology, that those ureters which had only been irradiated tolerated 30 and 60 Gy, resp., well and that the implanted ureters with subradical total focal dose of 30 Gy showed exact passage conditions in the i.v. urogram. (orig./MG) [de

  2. Tinnitus after Simultaneous and Sequential Bilateral Cochlear Implantation

    Directory of Open Access Journals (Sweden)

    Geerte G. J. Ramakers

    2017-11-01

    , four patients had an additional benefit of the second CI: a total suppression of tinnitus compared with their unilateral situation.ConclusionWhile bilateral cochlear implantation can have a positive effect on preoperative tinnitus complaints, the induction of (temporary or permanent tinnitus was also reported.Clinical Trial RegistrationDutch Trial Register NTR1722.

  3. The Prevalence of Dental Implants and Related Factors in Patients with Sjögren Syndrome: Results from a Cohort Study.

    Science.gov (United States)

    Albrecht, Katinka; Callhoff, Johanna; Westhoff, Gisela; Dietrich, Thomas; Dörner, Thomas; Zink, Angela

    2016-07-01

    To investigate prevalence and patient-reported outcomes of dental implants in patients with Sjögren syndrome (SS). A total of 205 female patients from an observational cohort study answered oral health questionnaires about periodontal signs and symptoms, dentures, dental implants, comorbidities, and therapies that may interfere with bone remodeling. Data were compared with the reports of 87 female healthy controls. The patients were older than the controls (58 ± 12 and 54 ± 14 yrs, respectively) and differed substantially in the prevalence of self-reported gingivitis (60% and 35%), self-reported periodontitis (19% and 8%), and in the numbers of remaining teeth (21 ± 7 and 24 ± 5). Patients more frequently had removable prostheses (36% compared with 23%) and dental implants (16% compared with 7%). The 32 patients with SS with dental implants had a mean number of 3.1 ± 2.0 implants. Notably, for patients with implants, their oldest existing implant survived for a mean period of 4.9 ± 5.4 years. A total of 5 of 104 (4.8%) implants in the patients and none of the 14 implants in the controls had to be removed. A total of 75% of the patients were highly satisfied with the implants and 97% would recommend them to other patients with SS. A substantial portion of patients with SS have dental complications and require subsequent implants. The majority were satisfied with the implants and would recommend them to other patients. The high implant survival rate may encourage patients, rheumatologists, and dentists to consider dental implants for the treatment of patients with SS.

  4. Mathematical filtering minimizes metallic halation of titanium implants in MicroCT images.

    Science.gov (United States)

    Ha, Jee; Osher, Stanley J; Nishimura, Ichiro

    2013-01-01

    Microcomputed tomography (MicroCT) images containing titanium implant suffer from x-rays scattering, artifact and the implant surface is critically affected by metallic halation. To improve the metallic halation artifact, a nonlinear Total Variation denoising algorithm such as Split Bregman algorithm was applied to the digital data set of MicroCT images. This study demonstrated that the use of a mathematical filter could successfully reduce metallic halation, facilitating the osseointegration evaluation at the bone implant interface in the reconstructed images.

  5. [Study on Microbial Diversity of Peri-implantitis Subgingival by High-throughput Sequencing].

    Science.gov (United States)

    Li, Zhi-jie; Wang, Shao-guo; Li, Yue-hong; Tu, Dong-xiang; Liu, Shi-yun; Nie, Hong-bing; Li, Zhi-qiang; Zhang, Ju-mei

    2015-07-01

    To study microbial diversity of peri-implantitis subgingival with high-throughput sequencing, and investigate microbiological etiology of peri-implantitis. Subgingival plaques were sampled from the patients with peri-implantitis (D group) and non-peri-implantitis subjects (N group). The microbiological diversity of the subgingival plaques was detected by sequencing V4 region of 16S rRNA with Illumina Miseq platform. The diversity of the community structure was analyzed using Mothur software. A total of 156 507 gene sequences were detected in nine samples and 4 402 operational taxonomic units (OTUs) were found. Selenomonas, Pseudomonas, and Fusobacterium were dominant bacteria in D group, while Fusobacterium, Veillonella and Streptococcus were dominant bacteria in N group. Differences between peri-implantitis and non-peri-implantitis bacterial communities were observed at all phylogenetic levels by LEfSe, which was also found in PcoA test. The occurrence of peri-implantitis is not only related to periodontitis pathogenic microbe, but also related with the changes of oral microbial community structure. Treponema, Herbaspirillum, Butyricimonas and Phaeobacte may be closely related to the occurrence and development of peri-implantitis.

  6. Granulomatous pseudotumors in total joint replacement

    International Nuclear Information System (INIS)

    Griffiths, H.J.; Burke, J.; Bonfiglio, T.A.

    1987-01-01

    Fourteen patients (15 joints) developed a foreign body reaction to methylmethacrylate, polyethylene, or metal adjacent to a total joint implant, a condition we would like to term granulomatous pseudotumors. There were eight male and six female patients. Their average age was 61 years. The hip was involved in 14 joints (femoral component 11 times, acetabulum 7, and greater trochanter once). One patient presented with granulomatous pseudotumors of the knee. The principal findings included increasing pain and radiographic evidence of loosening occurring on average 2.7 years following the implant. This was followed by a characteristic and gradually developing radiographic pattern of discrete rounded lucencies. These developed into large ovoid lytic areas, destroying both methylmethacrylate and bone. Histologically, the appearances were characterized by histiocytic infiltration and the presence of multiple foreign body giant cells. Foreign material was identified in 9 of 11 cases. The pathogenesis is unknown but appears related to micromovement or loosening of the implant. (orig.)

  7. Quality of YouTube TM videos on dental implants.

    Science.gov (United States)

    Abukaraky, A; Hamdan, A-A; Ameera, M-N; Nasief, M; Hassona, Y

    2018-07-01

    Patients search YouTube for health-care information. To examine what YouTube offers patients seeking information on dental implants, and to evaluate the quality of provided information. A systematic search of YouTube for videos containing information on dental implants was performed using the key words Dental implant and Tooth replacement. Videos were examined by two senior Oral and Maxillofacial Surgery residents who were trained and calibrated to perform the search. Initial assessment was performed to exclude non- English language videos, duplicate videos, conference lectures, and irrelevant videos. Included videos were analyzed with regard to demographics and content's usefulness. Information for patients available from the American Academy of Implant Dentistry, European Association of Osseointegration, and British Society of Restorative Dentistry were used for benchmarking. A total of 117 videos were analyzed. The most commonly discussed topics were related to procedures involved in dental implantology (76.1%, n=89), and to the indications for dental implants (58.1%, n=78). The mean usefulness score of videos was poor (6.02 ±4.7 [range 0-21]), and misleading content was common (30.1% of videos); mainly in topics related to prognosis and maintenance of dental implants. Most videos (83.1%, n=97) failed to mention the source of information presented in the video or where to find more about dental implants. Information about dental implants on YouTube is limited in quality and quantity. YouTube videos can have a potentially important role in modulating patients attitude and treatment decision regarding dental implants.

  8. Vaginally administered PEGylated LIF antagonist blocked embryo implantation and eliminated non-target effects on bone in mice.

    Directory of Open Access Journals (Sweden)

    Ellen Menkhorst

    Full Text Available Female-controlled contraception/HIV prevention is critical to address health issues associated with gender inequality. Therefore, a contraceptive which can be administered in tandem with a microbicide to inhibit sexually transmitted infections, is desirable. Uterine leukemia inhibitory factor (LIF is obligatory for blastocyst implantation in mice and associated with infertility in women. We aimed to determine whether a PEGylated LIF inhibitor (PEGLA was an effective contraceptive following vaginal delivery and to identify non-uterine targets of PEGLA in mice.Vaginally-applied (125I-PEGLA accumulated in blood more slowly (30 min vs 10 min and showed reduced tissue and blood retention (24 h vs 96 h compared to intraperitoneal injection in mice. Vaginally-applied PEGLA blocked implantation. PEGLA administered by intraperitoneal injection inhibited bone remodelling whereas vaginally-applied PEGLA had no effect on bone. Further, PEGLA had no effect in an animal model of multiple sclerosis, experimental auto-immune encephalomyelitis, suggesting PEGLA cannot target the central nervous system.Vaginally-administered PEGLA is a promising non-hormonal contraceptive, one which could be delivered alone, or in tandem with a microbicide. Vaginal application reduced the total dose of PEGLA required to block implantation and eliminated the systemic effect on bone, showing the vagina is a promising site of administration for larger drugs which target organs within the reproductive tract.

  9. Predicting the Failure of Dental Implants Using Supervised Learning Techniques

    Directory of Open Access Journals (Sweden)

    Chia-Hui Liu

    2018-05-01

    Full Text Available Prosthodontic treatment has been a crucial part of dental treatment for patients with full mouth rehabilitation. Dental implant surgeries that replace conventional dentures using titanium fixtures have become the top choice. However, because of the wide-ranging scope of implant surgeries, patients’ body conditions, surgeons’ experience, and the choice of implant system should be considered during treatment. The higher price charged by dental implant treatments compared to conventional dentures has led to a rush among medical staff; therefore, the future impact of surgeries has not been analyzed in detail, resulting in medial disputes. Previous literature on the success factors of dental implants is mainly focused on single factors such as patients’ systemic diseases, operation methods, or prosthesis types for statistical correlation significance analysis. This study developed a prediction model for providing an early warning mechanism to reduce the chances of dental implant failure. We collected the clinical data of patients who received artificial dental implants at the case hospital for a total of 8 categories and 20 variables. Supervised learning techniques such as decision tree (DT, support vector machines, logistic regressions, and classifier ensembles (i.e., Bagging and AdaBoost were used to analyze the prediction of the failure of dental implants. The results show that DT with both Bagging and Adaboost techniques possesses the highest prediction performance for the failure of dental implant (area under the receiver operating characteristic curve, AUC: 0.741; the analysis also revealed that the implant systems affect dental implant failure. The model can help clinical surgeons to reduce medical failures by choosing the optimal implant system and prosthodontics treatments for their patients.

  10. Simulation of the mechanical behavior of a HIP implant. Implant fixed to bone by cementation under arbitrary load

    Science.gov (United States)

    Oldani, C. R.; Dominguez, A. A.

    2007-11-01

    In a previous work a finite elements model was constructed to simulate a fatigue assay according to the norm IRAM 9422-3. Three materials were studied, two of them are the most used in this type of implant (Stainless steel 3161 and alloy T16A14V) and the third was a new developed titanium alloy (Ti35Nb7Zr5Ta). Static loads were applied to the model according to the highest requirements of the norm and the stress - strain distribution were determined. In this study a simplified analysis of the material's fatigue was done according to the previous work. The best behavior of the titanium alloys vs. the stainless steel was evident. With the objective of studying the behavior of both: the implant and the femur bone, new finite elements models were realized, in which the presence of the bone was considered. Inside the bone, the femoral component of the implant was placed in a similar way of a cemented prosthesis in a total hip arthroplasty. The advantage of the titanium implant related to the stainless steel one, was very clear.

  11. Simulation of the mechanical behavior of a HIP implant. Implant fixed to bone by cementation under arbitrary load

    Energy Technology Data Exchange (ETDEWEB)

    Oldani, C R [Materials Department - FCEFyN - Universidad Nacional de Cordoba, Av.Velez Sarsfield 1611 (5016) Cordoba (Argentina); Dominguez, A A [INTI Cordoba, Av. Velez Sarsfield 1561 (5016) Cordoba (Argentina)

    2007-11-15

    In a previous work a finite elements model was constructed to simulate a fatigue assay according to the norm IRAM 9422-3. Three materials were studied, two of them are the most used in this type of implant (Stainless steel 3161 and alloy T16A14V) and the third was a new developed titanium alloy (Ti35Nb7Zr5Ta). Static loads were applied to the model according to the highest requirements of the norm and the stress - strain distribution were determined. In this study a simplified analysis of the material's fatigue was done according to the previous work. The best behavior of the titanium alloys vs. the stainless steel was evident. With the objective of studying the behavior of both: the implant and the femur bone, new finite elements models were realized, in which the presence of the bone was considered. Inside the bone, the femoral component of the implant was placed in a similar way of a cemented prosthesis in a total hip arthroplasty. The advantage of the titanium implant related to the stainless steel one, was very clear.

  12. Clinical evaluation of a novel dental implant system as single implants under immediate loading conditions - 4-month post-loading results from a multicentre randomised controlled trial.

    Science.gov (United States)

    Esposito, Marco; Trullenque-Eriksson, Anna; Blasone, Rodolfo; Malaguti, Giuliano; Gaffuri, Cristiano; Caneva, Marco; Minciarelli, Armando; Luongo, Giuseppe

    To evaluate the safety and clinical effectiveness of a novel dental implant system (GENESIS Implant System, Keystone Dental, Massachusetts, USA) using another dental implant system by the same manufacturer as a control (PRIMA Implant System, Keystone Dental). A total of 53 patients requiring at least two single crowns had their sites randomised according to a split-mouth design to receive both implant systems at six centres. If implants could be placed with a torque superior to 40 Ncm they were to be loaded immediately with provisional crowns, otherwise after 3 months of submerged healing. Provisional crowns were replaced by definitive crowns 4 months after initial loading, when the follow-up period for the initial part of this study was completed. Outcome measures were crown/implant failures, complications, pink esthetic score (PES), peri-implant marginal bone level changes, plaque score, marginal bleeding, patients and preference of the clinician. In total 53 PRIMA and 53 GENESIS implants were placed. Three patients dropped out but all of the remaining patients were followed up to 4-months post-loading. No PRIMA implant failed whereas four GENESIS implants failed. Only two complications were reported for PRIMA implants. There were no statistically significant differences for crown/implant failures (difference in proportions = 0.080; P (McNemar test) = 0.125) and complications (difference in proportions = -0.04; P (McNemar test) = 0.500) between the implant systems. There were no differences at 4-months post-loading for plaque (difference = -0.54, 95% CI: -3.01 to 1.93; P (Paired t-test) = 0.660), marginal bleeding (difference = -3.8, 95% CI: -7.63 to 0.019; P (Paired t-test) = 0.051), PES (difference = 0.47, 95% CI: -0.56 to 1.50; P (Paired t-test) = 0.365) and marginal bone level changes (difference in mm = -0.04, 95% CI: -0.33 to 0.26; P (Paired t-test) = 0.795). The majority of the patients (46) had no

  13. Material Science in Cervical Total Disc Replacement

    Science.gov (United States)

    Pham, Martin H.; Mehta, Vivek A.; Tuchman, Alexander; Hsieh, Patrick C.

    2015-01-01

    Current cervical total disc replacement (TDR) designs incorporate a variety of different biomaterials including polyethylene, stainless steel, titanium (Ti), and cobalt-chrome (CoCr). These materials are most important in their utilization as bearing surfaces which allow for articular motion at the disc space. Long-term biological effects of implanted materials include wear debris, host inflammatory immune reactions, and osteolysis resulting in implant failure. We review here the most common materials used in cervical TDR prosthetic devices, examine their bearing surfaces, describe the construction of the seven current cervical TDR devices that are approved for use in the United States, and discuss known adverse biological effects associated with long-term implantation of these materials. It is important to appreciate and understand the variety of biomaterials available in the design and construction of these prosthetics and the considerations which guide their implementation. PMID:26523281

  14. Material Science in Cervical Total Disc Replacement.

    Science.gov (United States)

    Pham, Martin H; Mehta, Vivek A; Tuchman, Alexander; Hsieh, Patrick C

    2015-01-01

    Current cervical total disc replacement (TDR) designs incorporate a variety of different biomaterials including polyethylene, stainless steel, titanium (Ti), and cobalt-chrome (CoCr). These materials are most important in their utilization as bearing surfaces which allow for articular motion at the disc space. Long-term biological effects of implanted materials include wear debris, host inflammatory immune reactions, and osteolysis resulting in implant failure. We review here the most common materials used in cervical TDR prosthetic devices, examine their bearing surfaces, describe the construction of the seven current cervical TDR devices that are approved for use in the United States, and discuss known adverse biological effects associated with long-term implantation of these materials. It is important to appreciate and understand the variety of biomaterials available in the design and construction of these prosthetics and the considerations which guide their implementation.

  15. Breast reconstruction - implants

    Science.gov (United States)

    Breast implants surgery; Mastectomy - breast reconstruction with implants; Breast cancer - breast reconstruction with implants ... harder to find a tumor if your breast cancer comes back. Getting breast implants does not take as long as breast reconstruction ...

  16. Anchorage of TiO2-blasted, HA-coated, and machined implants: an experimental study with rabbits

    DEFF Research Database (Denmark)

    Gotfredsen, K; Wennerberg, A; Johansson, C

    1995-01-01

    The purpose of this study was to evaluate the histometrical and biomechanical anchorage of TiO2-blasted implants and TiO2-blasted implants coated with hydroxyapatite. The control implants were machined. Twenty-six rabbits had a total of 156 implants placed in the proximal part of the tibia. Each...... rabbit had a machined, a TiO2-blasted, and a TiO2-blasted, HA-coated implant placed in each tibia. After a healing period of 3 and 12 weeks, respectively, the implants placed in the right tibia were used for removal torque test, and the implants placed in the left tibia were used for histomorphometrical...

  17. ANALISIS TOTAL PRODUCTIVE MAINTENANCE PADA LINE 8/CARBONATED SOFT DRINK PT COCA-COLA BOTTLING INDONESIA CENTRAL JAVA

    Directory of Open Access Journals (Sweden)

    Darminto Pujotomo

    2012-02-01

    Full Text Available PT. Coca-Cola Bottling Indonesia (CCBI Central Java merupakan salah satu perusahaan produsen minuman ringan yang terkemuka di Indonesia, dengan dua jenis kelompok produk yang dihasilkan yaitu minuman karbonasi/Carbonated Soft Drink (Coca-Cola, Sprite, dan Fanta dan non-karbonasi (Frestea dan Ades. Dalam usaha untuk mempertahankan mutu dan meningkatkan produktifitas, salah satu faktor yang harus diperhatikan adalah masalah perawatan fasilitas/mesin produksi.  Makalah ini membahas mengenai penyebab dan akibat yang ditimbulkan oleh breakdown mesin terjadi pada Line 8/Carbonated Soft Drink, khususnya pada conveyor, filler machine, dan bottle washer machine. Untuk mendapatkan mesin yang dapat terjaga keterandalannya dibutuhkan suatu konsep yang baik. Total Productive Maintenance (TPM merupakan sebuah konsep yang baik untuk merealisasikan hal tersebut. Konsep ini, selain melibatkan semua personil dalam perusahaan, juga bertujuan untuk merawat semua fasilitas produksi yang dimiliki perusahaan.Data yang digunakan merupakan data breakdown conveyor, filler machine, dan bottle washer machine dari ME Monthly Report PT.CCBI selama bulan Januari-Desember 2005 khususnya line 8. Selain itu makalah ini juga membahas performance maintenance PT. Coca-Cola Bottling Indonesia-Central Java, dengan memperhitungkan nilai Mean Time Beetwen Failure (MTBF, Mean Time To Repair (MTTR, serta Availability mesin, dengan menggunakan data record Line 8 selama bulan Mei 2006 sampai bulan Juli 2006. Sehingga nantinya akan diketahui informasi keadaan aktual dari perusahaan tentang sistem perawatannya, khususnya pada Line 8/Carbonated Soft Drink apakah baik atau buruk. Kata kunci : Total Production Maintenance, Conveyor, Filler Machine, Bottle Washer Machine, Performance Maintenance   PT. Coca-Cola Bottling Indonesia (CCBI-Central Java represent one of notable light beverage producer company in Indonesia, with two product group type yielded is carbonated beverage/Carbonated Soft

  18. [Catheter fracture and pulmonary embolization of the distal fragment: a rare complication of the totally implantable venous access port].

    Science.gov (United States)

    Rebahi, H; El Adib, A G; Mouaffak, Y; El Hattaoui, M; Chaara, A; Sadek, H; Khouchani, M; Mahmal, L; Younous, S

    2015-01-01

    Totally implantable venous access port plays a crucial role in the treatment of patients in oncology. However, its use can result sporadically in catheter fracture with catheter tip embolization into pulmonary arteries. We report this unusual but potentially serious complication in four patients. In these patients, the port had been inserted percutaneously into the subclavian vein using the infra-clavicular approach. This side effect occurred late in three patients. In all patients, the catheter fracture was asymptomatic or pauci-symptomatic and was caused by the pinch-off syndrome. The retrieval of the embolized fragments was successfully performed by transcatheter procedure in the cardiac catheterisation laboratory. We reviewed the literature and the newest guidelines and recommendations to detail the clinico-radiological features, the possible causes of this complication and discussed means to recognize, manage and prevent it. Copyright © 2013 Société nationale française de médecine interne (SNFMI). Published by Elsevier SAS. All rights reserved.

  19. Precision of fit between implant impression coping and implant replica pairs for three implant systems.

    Science.gov (United States)

    Nicoll, Roxanna J; Sun, Albert; Haney, Stephan; Turkyilmaz, Ilser

    2013-01-01

    The fabrication of an accurately fitting implant-supported fixed prosthesis requires multiple steps, the first of which is assembling the impression coping on the implant. An imprecise fit of the impression coping on the implant will cause errors that will be magnified in subsequent steps of prosthesis fabrication. The purpose of this study was to characterize the 3-dimensional (3D) precision of fit between impression coping and implant replica pairs for 3 implant systems. The selected implant systems represent the 3 main joint types used in implant dentistry: external hexagonal, internal trilobe, and internal conical. Ten impression copings and 10 implant replicas from each of the 3 systems, B (Brånemark System), R (NobelReplace Select), and A (NobelActive) were paired. A standardized aluminum test body was luted to each impression coping, and the corresponding implant replica was embedded in a stone base. A coordinate measuring machine was used to quantify the maximum range of displacement in a vertical direction as a function of the tightening force applied to the guide pin. Maximum angular displacement in a horizontal plane was measured as a function of manual clockwise or counterclockwise rotation. Vertical and rotational positioning was analyzed by using 1-way analysis of variance (ANOVA). The Fisher protected least significant difference (PLSD) multiple comparisons test of the means was applied when the F-test in the ANOVA was significant (α=.05). The mean and standard deviation for change in the vertical positioning of impression copings was 4.3 ±2.1 μm for implant system B, 2.8 ±4.2 μm for implant system R, and 20.6 ±8.8 μm for implant system A. The mean and standard deviation for rotational positioning was 3.21 ±0.98 degrees for system B, 2.58 ±1.03 degrees for system R, and 5.30 ±0.79 degrees for system A. The P-value for vertical positioning between groups A and B and between groups A and R was <.001. No significant differences were found for

  20. [Guided and computer-assisted implant surgery and prosthetic: The continuous digital workflow].

    Science.gov (United States)

    Pascual, D; Vaysse, J

    2016-02-01

    New continuous digital workflow protocols of guided and computer-assisted implant surgery improve accuracy of implant positioning. The design of the future prosthesis is based on the available prosthetic space, gingival height and occlusal relationship with the opposing and adjacent teeth. The implant position and length depend on volume, density and bone quality, gingival height, tooth-implant and implant-implant distances, implant parallelism, axis and type of the future prosthesis. The crown modeled on the software will therefore serve as a guide to the future implant axis and not the reverse. The guide is made by 3D printing. The software determines surgical protocol with the drilling sequences. The unitary or plural prosthesis, modeled on the software and built before surgery, is loaded directly after implant placing, if needed. These protocols allow for a full continuity of the digital workflow. The software provides the surgeon and the dental technician a total freedom for the prosthetic-surgery guide design and the position of the implants. The prosthetic project, occlusal and aesthetic, taking the bony and surgical constraints into account, is optimized. The implant surgery is simplified and becomes less "stressful" for the patient and the surgeon. Guided and computer-assisted surgery with continuous digital workflow is becoming the technique of choice to improve the accuracy and quality of implant rehabilitation. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  1. Computerized axial tomography : the tool in osseointegrated dental implants

    International Nuclear Information System (INIS)

    Fernandez-Lopez, Otton

    2002-01-01

    Failure rates in rehabilitations with osseointegrated implants are handled through appropriate radiographic preoperative planning. The appropriate length of the implant without running the risk of a perforation of vital structures, has been determined by a radiographic diagnosis. Computerized and conventional axial tomography have proved to be invaluable elements for pre-surgical evaluation. A radiologic guidance is elaborated to perform a computerized axial tomography (CT) of maxillary bones in totally edentulous patients. Surgical guides are constructed from a wax-up emanated from the information of the CT. The CT has proven to be an radiographic indispensable element to achieve the surgical-prosthetic success in osseointegrated dental implants. The CT has allowed the realization of a precise wax-up for making of surgical guide and a precise temporary prostheses in positioning of osseointegrated implants, with the consequent saving time and money for the rehabilitator and patient [es

  2. Multicycle mechanical performance of titanium and stainless steel transpedicular spine implants.

    Science.gov (United States)

    Pienkowski, D; Stephens, G C; Doers, T M; Hamilton, D M

    1998-04-01

    This was a prospective in vitro study comparing titanium alloy and stainless steel alloy in transpedicular spine implants from two different manufactures. To compare the multicycle mechanical performance of these two alloys, used in each of two different implant designs. Transpedicular spine implants primarily have been manufactured from stainless steel, but titanium alloy offers imaging advantages. However, the notch sensitivity of titanium alloy has caused concern regarding how implants made from this material will compare in stiffness and fatigue life with implants made from stainless steel. Twenty-four implants (two alloys, two designs, six implants per group) were mounted in machined polyethylene wafers and repetitively loaded (up to 1 million cycles) from 80 N to 800 N using a 5-Hertz sinusoidal waveform. Load and displacement data were automatically and periodically sampled throughout the entire test. Implant stiffness increased with cycle load number, reached a steady state, then declined just before fatigue failure. Stiffness varied less in titanium transpedicular spine implants than in their stainless counterparts. All stainless steel implant types were stiffer (steady-state value, P titanium alloy counterparts. One titanium implant design failed with fewer (P stainless steel counterpart, whereas a stainless steel implant of another design failed with fewer (P titanium counterpart. Overall, fatigue life, i.e., the total number of load cycles until failure, was related to implant type (P implant material. A transpedicular spine implant's fatigue lifetime depends on both the design and the material and cannot be judged on material alone. Stainless steel implants are stiffer than titanium alloy implants of equal design and size; however, for those designs in which the fatigue life of the titanium alloy version is superior, enlargement of the implant's components can compensate for titanium's lower modulus of elasticity and result in an implant equally stiff

  3. Salivary bacterial leakage into implant-abutment connections: preliminary results of an in vitro study.

    Science.gov (United States)

    Mencio, F; Papi, P; Di Carlo, S; Pompa, G

    2016-06-01

    The occurrence of bacterial leakage in the internal surface of implants, through implant-abutment interface (IAI), is one of the parameters for analyzing the fabrication quality of the connections. The aim of this in vitro study is to evaluate two different types of implant-abutment connections: the screwed connection (Group 1) and the cemented connection (Group 2), analyzing the permeability of the IAI to bacterial colonization, using human saliva as culture medium. A total of twelve implants were tested, six in each experimental group. Five healthy patients were enrolled in this study. Two milliliters of non-stimulated saliva were collected from each subject and mixed in a test tube. After 14 days of incubation of the bacteria sample in the implant fixtures, a PCR-Real Time analysis was performed. Fisher's exact test was used to compare the proportions of implant-abutment assembled structures detected with bacterial leakage. Differences in the bacterial counts of the two groups were compared using the Mann-Whitney U test. A p value abutment connections compared to the cemented implant-abutment connections. A mean total bacterial count of 1.2E+07 (± 0.25E+07) for Group 1 and of 7.2E+04 (± 14.4E+04) for Group 2 was found, with a high level of significance, p = .0001. Within the limitations of this study it can be concluded that bacterial species from human saliva may penetrate along the implant-abutment interface in both connections, however the cemented connection implants showed the lowest amount of bacterial colonization.

  4. Cobalt Alloy Implant Debris Induces Inflammation and Bone Loss Primarily through Danger Signaling, Not TLR4 Activation: Implications for DAMP-ening Implant Related Inflammation

    OpenAIRE

    Samelko, Lauryn; Landgraeber, Stefan; McAllister, Kyron; Jacobs, Joshua; Hallab, Nadim James

    2016-01-01

    Cobalt alloy debris has been implicated as causative in the early failure of some designs of current total joint implants. The ability of implant debris to cause excessive inflammation via danger signaling (NLRP3 inflammasome) vs. pathogen associated pattern recognition receptors (e.g. Toll-like receptors; TLRs) remains controversial. Recently, specific non-conserved histidines on human TLR4 have been shown activated by cobalt and nickel ions in solution. However, whether this TLR activation ...

  5. The Effect of RANKL/OPG Balance on Reducing Implant Complications

    Directory of Open Access Journals (Sweden)

    Elizabeth R. Kapasa

    2017-09-01

    Full Text Available Despite the phenomenal success of implants particularly in the realms of dentistry and orthopaedics, there are still challenges to overcome. The failure of implants resulting from infection, prosthetic loosening, and non-union continue to be the most notorious examples. The cascade of fracture healing and bone repair, especially with the presence of an implant, is complex because it involves a multifaceted immune response alongside the intricate process of bone formation and remodelling. Bone loss is a serious clinical problem that is frequently accompanied by chronic inflammation, illustrating that there is a convoluted relationship between inflammation and bone erosion. The effects of pro-inflammatory factors play a significant role in initiating and maintaining osteoclastogenesis that results in bone resorption by osteoclasts. This is because there is a disruption of the relative ratio between Receptor Activator of Nuclear Factor κB-Ligand (RANKL and osteoprotegerin (OPG, which is central to modulating bone repair and remodelling. This review aims to provide a background to the bone remodelling process, the bone repair cascade post-implantation, and the associated complications. Furthermore, current clinical solutions that can influence bone formation via either internal or extrinsic mechanisms will be described. These efficacious treatments for osteolysis via targeting the RANKL/OPG ratio may be crucial to reducing the incidence of related implant failures in the future.

  6. Effect of implant macro-design on primary stability: A prospective clinical study.

    Science.gov (United States)

    Lozano-Carrascal, Naroa; Salomó-Coll, Oscar; Gilabert-Cerdà, Marta; Farré-Pagés, Nuria; Gargallo-Albiol, Jordi; Hernández-Alfaro, Federico

    2016-03-01

    Implant restorations have become a high predictable treatment option. Several caracteristics such as surgical technique and implant design can influence the treatment outcomes. The aim of the present study was to evaluate the influence of implant macro-design on primary stability measured with resonance frequency analysis (RFA) and insertion torque (IT). Material and Mehods: A total of 47 implants divided in two groups: Test group (TI): 22 Tapered MIS® Seven implants; Control group (CI): 25 cylindrical Astra® Osseospeed implants. All implants were inserted following the manufacturers' standard protocols. Implant primary stability was measured at the moment of implant placement by registering insertion torque values (ITv) and ISQ values by means of Osstell™ Mentor (ISQv) (Integration Diagnostic Ltd., Goteborg, Sweden). In the mandible, mean ISQv for tapered implants (TI) was 71.67±5.16 and for cylindrical implants (CI) 57.15±4.83 (p=0.01). Mean insertion torque was 46.67±6.85 Ncm for TI and 35.77±6.72 Ncm for CI (p=0.01). In the maxilla, mean ISQ was 67.2±4.42 for tapered implants and 49.17±15.30 for cylindrical implants (p=0.01). Mean insertion torque for TI was 41.5±6.26 Ncm and for CI 39.17±6.34 Ncm (p>0.05). For tapered implants, no correlation could be found between implant diameter and primary stability. But for cylindrical implants there was a statistically significant correlation between implant diameter and primary stability: ITv (p=0.03); ISQv (p=0.04). Within the limits of the present study, tapered shaped implants achieve higher primary stability measured through ISQ and insertion torque values. Moreover, for cylindrical implants positive correlation has been established between implant diameter and primary stability.

  7. Intrinsic constraint of unlinked total elbow replacements--the ulnotrochlear joint.

    Science.gov (United States)

    Kamineni, S; O'Driscoll, S W; Urban, M; Garg, A; Berglund, L J; Morrey, B F; An, K N

    2005-09-01

    Many unlinked total elbow replacement designs with radically differing articular geometries exist, suggesting that there is no consensus regarding an optimal design. A feature inherent to the articular design is the intrinsic constraint afforded to the joint by the implant. Our aim was to compare the intrinsic constraints of unlinked implants with that of the normal ulnotrochlear joint. We tested twelve cadaveric ulnotrochlear joints with a custom-made multiple-axis materials testing machine. With compressive loads ranging from 10 to 100 N, the joints were moved in either valgus or varus directions at 90 degrees of flexion. The ulnotrochlear components from a single example of five medium-sized unlinked elbow replacements (Ewald, Kudo, Pritchard ERS, Sorbie-Questor, and Souter-Strathclyde) were also tested. The recorded measurements included the torques and forces, angular displacement, and axial displacement of the humerus relative to the ulna. In general, the peak torque and the constraint ratio significantly increased with increasing compressive load for the implants as well as for the normal elbow. In valgus displacement, the Souter-Strathclyde implant had the highest and the Sorbie-Questor had the smallest peak torque and the Souter-Strathclyde had the highest and the Ewald had the smallest constraint ratio. In varus displacement, the Kudo had the highest and the Ewald had the smallest peak torque and constraint ratio. The constraint ratio is a characteristic that is useful for describing elbow joint behavior and for comparing the behavior of implants with that of the human elbow. Of the unlinked implants tested, the Souter-Strathclyde and Kudo prostheses most closely approximated the behavior of the human elbow joint. Implants that resemble the human elbow in appearance do not replicate normal behavior consistently, whereas other implants that do not resemble the human elbow closely do not deviate markedly from human behavior. Thus, much basic information

  8. Viability of dental implants in head and neck irradiated patients: A systematic review.

    Science.gov (United States)

    Zen Filho, Edson Virgílio; Tolentino, Elen de Souza; Santos, Paulo Sérgio Silva

    2016-04-01

    The purpose of this systematic review was to evaluate the safety of dental implants placed in irradiated bone and to discuss their viability when placed post-radiotherapy (RT). A systematic review was performed to answer the questions: "Are dental implants in irradiated bone viable?" and "What are the main factors that influence the loss of implants in irradiated patients?" The search strategy resulted in 8 publications. A total of 331 patients received 1237 implants, with an overall failure rate of 9.53%. The osseointegration success rates ranged between 62.5% and 100%. The optimal time interval between irradiation and dental implantation varied from 6 to 15 months. The interval time between RT and implant placement and the radiation doses are not associated with significant implant failure rates. The placement of implants in irradiated bone is viable, and head and neck RT should not be considered as a contraindication for dental rehabilitation with implants. © 2015 Wiley Periodicals, Inc. Head Neck 38: E2229-E2240, 2016. © 2015 Wiley Periodicals, Inc.

  9. Ion implantation

    International Nuclear Information System (INIS)

    Johnson, E.

    1986-01-01

    It is the purpose of the present paper to give a review of surface alloy processing by ion implantation. However, rather than covering this vast subject as a whole, the survey is confined to a presentation of the microstructures that can be found in metal surfaces after ion implantation. The presentation is limited to alloys processed by ion implantation proper, that is to processes in which the alloy compositions are altered significantly by direct injection of the implanted ions. The review is introduced by a presentation of the processes taking place during development of the fundamental event in ion implantation - the collision cascade, followed by a summary of the various microstructures which can be formed after ion implantation into metals. This is compared with the variability of microstructures that can be achieved by rapid solidification processing. The microstructures are subsequently discussed in the light of the processes which, as the implantations proceed, take place during and immediately after formation of the individual collision cascades. These collision cascades define the volumes inside which individual ions are slowed down in the implanted targets. They are not only centres for vigorous agitation but also the sources for formation of excess concentrations of point defects, which will influence development of particular microstructures. A final section presents a selection of specific structures which have been observed in different alloy systems. (orig./GSCH)

  10. Alveolar nerve repositioning with rescue implants for management of previous treatment. A clinical report.

    Science.gov (United States)

    Amet, Edward M; Uehlein, Chris

    2013-12-01

    The goal of modern implant dentistry is to return patients to oral health in a rapid and predictable fashion, following a diagnostically driven treatment plan. If only a limited number of implants can be placed, or some fail and the prosthetic phase of implant dentistry is chosen to complete the patient's treatment, the final outcome may result in partial patient satisfaction and is commonly referred to as a "compromise." Previous All-on-4 implant treatment for the patient presented here resulted in a compromise, with an inadequate support system for the mandibular prosthesis and a maxillary complete denture with poor esthetics. The patient was unable to function adequately and also was disappointed with the resulting appearance. Correction of the compromised treatment consisted of bilateral inferior alveolar nerve elevation and repositioning without bone removal for lateral transposition, to gain room for rescue implants for a totally implant-supported and stabilized prosthesis. Treatment time to return the patient to satisfactory comfort, function, facial esthetics, and speech was approximately 2 weeks. The definitive mandibular prosthesis was designed for total implant support and stability with patient retrievability. Adequate space between the mandibular bar system and the soft tissue created a high water bridge effect for self-cleansing. Following a short interim mandibular healing period, the maxillary sinuses were bilaterally grafted to compensate for bone inadequacies and deficiencies for future maxillary implant reconstruction. © 2013 by the American College of Prosthodontists.

  11. Masticatory efficiency and oral health-related quality of life with implant-retained mandibular overdentures

    Science.gov (United States)

    Sun, Xu; Zhai, Jun-Jiang; Liao, Jian; Teng, Min-Hua; Tian, Ai; Liang, Xing

    2014-01-01

    Objectives: To evaluate masticatory efficiency (ME) and oral health-related quality of life (OHRQoL) in patients rehabilitated with implant-retained mandibular overdentures. Methods: In this randomized controlled clinical trial, 50 edentulous patients visiting the Implant Center and Department of Prosthodontics, West China College of Stomatology, Sichuan University, Chengdu, China between June 2010 and June 2012 were selected and received 2 implant-retained mandibular overdenture treatments. All patients were rehabilitated with maxillary complete dentures. The ME and OHRQoL were determined both one month before the mandibular complete denture was anchored to the osseointegrated implants, and 6 months after anchoring. Paired t-tests were used to compare means of ME, and oral health impact profile-49 (OHIP-49) domains scores between pre- and post-implant. Linear regression models were utilized to seek correlations between ME and OHIP domains scores. Results: The ME increased from pre- to post-implant retained mandibular overdentures significantly (p<0.001). The total OHIP score and 4 subscales scores were changed significantly from pre- to post-implant; namely, functional limitation, psychological discomfort, physical disability, and physical pain. The total OHIP score, functional limitation, physical disability, and physical pain subscale scores were related to ME. Conclusion: Implant-retained mandibular over dentures can significantly improve patients’ ME and OHRQoL. The improvement in OHRQoL is mainly because of the improved ME. An improved chewing experience, and pain relief also contributes to improvement of OHRQoL. PMID:25316463

  12. Finite element analysis to compare complete denture and implant-retained overdentures with different attachment systems.

    Science.gov (United States)

    Barão, Valentim Adelino Ricardo; Assunção, Wirley Gonçalves; Tabata, Lucas Fernando; Delben, Juliana Aparecida; Gomes, Erica Alves; de Sousa, Edson Antonio Capello; Rocha, Eduardo Passos

    2009-07-01

    This finite element analysis compared stress distribution on complete dentures and implant-retained overdentures with different attachment systems. Four models of edentulous mandible were constructed: group A (control), complete denture; group B, overdenture retained by 2 splinted implants with bar-clip system; group C, overdenture retained by 2 unsplinted implants with o'ring system; and group D, overdenture retained by 2 splinted implants with bar-clip and 2 distally placed o'ring system. Evaluation was performed on Ansys software, with 100-N vertical load applied on central incisive teeth. The lowest maximum general stress value (in megapascal) was observed in group A (64.305) followed by groups C (119.006), D (258.650), and B (349.873). The same trend occurred in supporting tissues with the highest stress value for cortical bone. Unsplinted implants associated with the o'ring attachment system showed the lowest maximum stress values among all overdenture groups. Furthermore, o'ring system also improved stress distribution when associated with bar-clip system.

  13. Replacement of missing tooth in esthetic zone with implant-supported fixed prosthesis

    Directory of Open Access Journals (Sweden)

    Sunil Kumar Mishra

    2017-01-01

    Full Text Available In the anterior region, the common reason for tooth loss is due to traumatic injury or congenital anomaly. Loss of a single tooth may cause functional and esthetic deficits to the patient. There are different treatment options available for replacing a missing incisor. Implant dentistry should be considered as first treatment alternative for replace a missing tooth. This case report presents the replacement of a missing maxillary left central incisor in a compromised site with dental implants along with bone graft followed by frenectomy to obtain a good clinical result and for better function and esthetics of the patient.

  14. The association between metal allergy, total knee arthroplasty, and revision

    DEFF Research Database (Denmark)

    Münch, Henrik J; Jakobsen, Stig Storgaard; Olesen, Jens T

    2015-01-01

    BACKGROUND AND PURPOSE: It is unclear whether delayed-type hypersensitivity reactions against implanted metals play a role in the etiopathogenesis of malfunctioning total knee arthroplasties. We therefore evaluated the association between metal allergy, defined as a positive patch test reaction...... to common metal allergens, and revision surgery in patients who underwent knee arthroplasty. PATIENTS AND METHODS: The nationwide Danish Knee Arthroplasty Register, including all knee-implanted patients and revisions in Denmark after 1997 (n = 46,407), was crosslinked with a contact allergy patch test......, the prevalence of cobalt and chromium allergy was markedly higher. Metal allergy that was diagnosed before implant surgery appeared not to increase the risk of implant failure and revision surgery. INTERPRETATION: While we could not confirm that a positive patch test reaction to common metals is associated...

  15. TOTAL HIP REPLACEMENTS AT KIKUYU HOSPITAL, KENYA

    African Journals Online (AJOL)

    equipments, few trained personnel and the high cost of implants. It is mainly in the ..... function more affected than the sensory a day after. There was a foot drop. .... 60: Issue 2, 217-. 220. 13. NIH Consensus Development Panel on Total Hip.

  16. Radiation protection after interstitial permanent prostate brachytherapy implants

    Energy Technology Data Exchange (ETDEWEB)

    Pirraco, R.; Pereira, A.; Cavaco, A. [Instituto Portugues de Oncologia Francisco Gentil - Centro R egional de Oncologia do Porto, SA, Porto (Portugal)

    2006-07-01

    Full text of publication follows: In this study we measure patients radiation exposure dose after interstitial {sup 125}I permanent prostate Brachytherapy implants, and correlate it with dose limits for public, total activity implanted, patient preoperative weight(1), distance between prostate walls and anterior skin surface. Methods and Material: We analyse 20 patients who were implanted with {sup 125}I seeds. The instrument used to measure radiation is a calibrated Berthold Umo LB 123 aco-plated to a LB 1236-H10 detector. Three measurements were taken: at the perineal and anterior pelvic zones on contact with the skin and at 1 m from the patient. The maximum value was taken for all measurements. The dose at a distance of one meter is obtained at anterior pelvic zone, perpendicular to the skin, according to the recommendations of A.A.P.M.(1). The distance between prostate walls was determined using post -operative CT images. Results: The doses at the perineal zone have determined an average of 186 {mu}Sv/h (range: 110 340 {mu}Sv/h) and at surface pelvic zone of 41 {mu}Sv/h (range: 15 103 {mu}Sv/h). The dose at a distance of 1 meter has an average value of 0.4 {mu}Sv/h (range: 0.2 1.0 {mu}Sv/h). The average total activity implanted was 25 mCi (range: 17 38 mCi). The distance between prostate walls and skin pelvic surface of the patients has an average value of 8.9 cm (range: 6.6 -11.5 cm). At a distance of 1 meter from the pelvic zone the dose measured is very low and below dose limits imposed by the European Directive EURATOM 2 and the Portuguese law. For general public to reach annual dose limit (EURATOM - 1 mSv/year) when contacting the pelvic zone, we extrapolate that 4 days (range: 1.6 11.1 days) would be needed, assuming a daily contact period of 6 hours. Conclusion: We established a correlation between the distance of prostate walls to the skin perineal surface and the total dose, but we find no correlation between measured doses, total activity implanted

  17. Optimizing Maxillary Aesthetics of a Severe Compromised Tooth through Orthodontic Movement and Dental Implants

    Directory of Open Access Journals (Sweden)

    Rafael Scaf de Molon

    2014-01-01

    Full Text Available Treatment of severe compromised tooth in the maxillary anterior area still poses great challenge to the clinicians. Several treatment modalities have been proposed to restore the function and aesthetics in teeth with advanced periodontal disease. The present study aims to report a case of traumatic injury of a left-maxillary central incisor with ridge preservation, orthodontic movement, and implant therapy. A 45-year-old woman underwent the proposed treatment for her left central incisor: basic periodontal therapy, xenogenous bone graft, and guided bone regeneration (GBR. Six months after the graft procedure, orthodontic movement by means of alignment and leveling was made and a coronal displacement of the gingival margin and vertical bone apposition could be observed after 13 months of active movement. Afterwards, a dental implant was placed followed by a connective tissue graft and immediate provisionalization of the crown. In conclusion, orthodontic movement was effective to improve the gingival tissue and alveolar bone prior to implant placement favoring the aesthetic results. Six years postoperatively, the results revealed height and width alveolar bone gain indicating that the treatment proposed was able to restore all the functional and aesthetic parameters.

  18. Comparison of two dental implant surface modifications on implants with same macrodesign: an experimental study in the pelvic sheep model.

    Science.gov (United States)

    Ernst, Sabrina; Stübinger, Stefan; Schüpbach, Peter; Sidler, Michéle; Klein, Karina; Ferguson, Stephen J; von Rechenberg, Brigitte

    2015-08-01

    The aim of this study was to compare two different surfaces of one uniform macro-implant design in order to focus exclusively on the osseointegration properties after 2, 4 and 8 weeks and to discuss the animal model chosen. In six mature sheep, n = 36 implants with a highly crystalline and phosphate-enriched anodized titanium oxide surface (TiU) and n = 36 implants with a hydrophilic, sandblasted, large grit and acid-etched surface (SLA) were placed in the pelvic bone. TiU implants were custom-made to match the SLA implant design. The implant stability and bone-to-implant contact (BIC) were assessed by resonance frequency (ISQ), backscatter scanning electron microscopy (B-SEM), light microscopy (LM), micro-CT and intravital fluorochrome staining. Biomechanical removal torque testing was performed. Overall, no statistically significant differences in BIC total (trabecular + cortical) between TiU and SLA were found via LM and B-SEM. BIC values (B-SEM; LM) in both groups revealed a steady rise in trabecular bone attachment to the implant surface after 2, 4 and 8 weeks. In the 2- to 4-week time interval in the TiU group (P = 0.005) as well as in the SLA group (P = 0.01), a statistically significant increase in BIC trabecular could be observed via LM. B-SEM values confirmed the statistically significant increase for TiU (P = 0.001). In both groups, BIC trabecular values after 8 weeks were significantly higher (P ≤ 0.05) than after 2 weeks (B-SEM; LM). Biomechanical data confirmed the histological data. The two surfaces proved comparable osseointegration in this sheep model. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  19. Balance Performance of Deaf Children With and Without Cochlear Implants

    Directory of Open Access Journals (Sweden)

    Amir-Abbas Ebrahimi

    2016-12-01

    Full Text Available  The aim of this study was to compare the static and dynamic balance performance of deaf children with and without cochlear implants. This is a cross-sectional study of 145 school children, aged between 7 and 12 years comprising 85 children with congenital or early acquired bilateral profound sensorineural hearing loss (the hearing loss group and 60 normal hearing aged-matched control counterparts were assessed using the balance subtest of Bruininks-Oseretsky test of Motor Proficiency (BOTMP. The hearing loss group, 50 without cochlear implants (the non-implant group and 35 of them with unilateral cochlear implants (the implant group were recruited from schools for the deaf and normal hearing children (the control group randomly selected from two randomly selected elementary schools of Tehran city. The scores were analyzed using one-way ANOVA. The total score of deaf children especially the implant group were significantly lower than the control group P<0.001. The balance performance of the control group was better than the implant group in all of the items as well as the non-implant group except the fourth tested item (walking forward on a line (P<0.05. The balance score of the implant group was significantly lower than the non-implant group except for the third tested item (standing on the preferred leg on a balance beam with eyes closed. The findings suggested that deaf children, specifically those with cochlear implants are at risk for motor and balance deficits. Thus, vestibular and motor evaluations, as well as interventions to improve balance and motor skills, should be prioritized for this population.

  20. Tribological properties of nitrogen implanted and boron implanted steels

    International Nuclear Information System (INIS)

    Kern, K.T.

    1996-01-01

    Samples of a steel with high chrome content was implanted separately with 75 keV nitrogen ions and with 75 keV boron ions. Implanted doses of each ion species were 2-, 4-, and 8 x 10 17 /cm 2 . Retained doses were measured using resonant non-Rutherford Backscattering Spectrometry. Tribological properties were determined using a pin-on-disk test with a 6-mm diameter ruby pin with a velocity of 0.94 m/min. Testing was done at 10% humidity with a load of 377 g. Wear rate and coefficient of friction were determined from these tests. While reduction in the wear rate for nitrogen implanted materials was observed, greater reduction (more than an order of magnitude) was observed for boron implanted materials. In addition, reduction in the coefficient of friction for high-dose boron implanted materials was observed. Nano-indentation revealed a hardened layer near the surface of the material. Results from grazing incidence x-ray diffraction suggest the formation of Fe 2 N and Fe 3 N in the nitrogen implanted materials and Fe 3 B in the boron implanted materials. Results from transmission electron microscopy will be presented

  1. Cochlear implantation in late-implanted adults with prelingual deafness.

    Science.gov (United States)

    Most, Tova; Shrem, Hadas; Duvdevani, Ilana

    2010-01-01

    The purpose of this study was to examine the effect of cochlear implantation (CI) on prelingually deafened participants who were implanted as adults. The effect of the CI was examined with regard to the following variables: communication, family, social skills, education, and work satisfaction with one's life, loneliness, and self-esteem. Thirty-eight adults participated. Four self-report questionnaires were used at 2 points in time: before and after CI. The research findings show significant differences in the reports of most variables before and after implantation. The participants felt better with regard to communication, social skills, education, and work and satisfaction with one's life after implantation in comparison to their feelings before implantation. Furthermore, they felt less lonely after implantation. However, there were no significant differences before and after implantation regarding their feelings within the family and regarding their self-esteem. The results demonstrated the need to evaluate the benefits resulting from the CI not only with traditional clinical measures but with additional measures as well. Furthermore, they demonstrated the benefit of the CI on the positive psychosociological implications of prelingually deafened adults. Copyright © 2010 Elsevier Inc. All rights reserved.

  2. Histology of a dental implant with a platform switched implant-abutment connection

    Directory of Open Access Journals (Sweden)

    Vittoria Perrotti

    2011-10-01

    Full Text Available Background: Peri-implant crestal bone must be stable for aesthetic reasons. Aim of this study was a histologic analysis of an implant with a platform switched implant-abutment connection. Materials and methods: A 32-year-old male patient participated in this study. The patient needed a bilateral mandibular restoration. Four implants were used, and were immediately restored and loaded the same day of insertion. After a 6 weeks healing period, one implant with platform-switched abutment was retrieved with trephine. Before retrieval the implant was osseointegrated and not mobile. On one side of the implant, a 1 mm resorption of the crestal bone was present. On the contrary, on the other side no bone resorption had occurred and about 1 mm of bone was present over the implant shoulder. Results: The bone-implant contact percentage was 65.1 ± 6.3 %. Platform- switching could help in maintaining the height of the peri-implant crestal bone.

  3. Placement of the stemless humeral component in the Total Evolutive Shoulder System (TESS).

    Science.gov (United States)

    Geurts, Ghislain F; van Riet, Roger P; Jansen, Nick; Declercq, Geert

    2010-12-01

    Humeral implant design in shoulder arthroplasty has evolved over the years. The third generation shoulder prostheses have an anatomic humeral stem that replicates the 3-dimensional parameters of the proximal humerus. The overall complication rate has decreased as a result of these changes in implant design. In contrast, the rate of periprosthetic humeral fractures has increased. To avoid stem-related complications while retaining the advantages of the third generation of shoulder implants, the stemless total evolutive shoulder system has been developed. The indications, the surgical technique, and the complications of this humeral implant in shoulder arthroplasty will be described.

  4. Effectiveness of Implant Therapy Analyzed in a Swedish Population: Prevalence of Peri-implantitis.

    Science.gov (United States)

    Derks, J; Schaller, D; Håkansson, J; Wennström, J L; Tomasi, C; Berglundh, T

    2016-01-01

    Peri-implantitis is an inflammatory disease affecting soft and hard tissues surrounding dental implants. As the global number of individuals that undergo restorative therapy through dental implants increases, peri-implantitis is considered as a major and growing problem in dentistry. A randomly selected sample of 588 patients who all had received implant-supported therapy 9 y earlier was clinically and radiographically examined. Prevalence of peri-implantitis was assessed and risk indicators were identified by multilevel regression analysis. Forty-five percent of all patients presented with peri-implantitis (bleeding on probing/suppuration and bone loss >0.5 mm). Moderate/severe peri-implantitis (bleeding on probing/suppuration and bone loss >2 mm) was diagnosed in 14.5%. Patients with periodontitis and with ≥4 implants, as well as implants of certain brands and prosthetic therapy delivered by general practitioners, exhibited higher odds ratios for moderate/severe peri-implantitis. Similarly, higher odds ratios were identified for implants installed in the mandible and with crown restoration margins positioned ≤1.5 mm from the crestal bone at baseline. It is suggested that peri-implantitis is a common condition and that several patient- and implant-related factors influence the risk for moderate/severe peri-implantitis (ClinicalTrials.gov NCT01825772). © International & American Associations for Dental Research 2015.

  5. Immediate loading of subcrestally placed dental implants in anterior and premolar sites.

    Science.gov (United States)

    Henningsen, Anders; Smeets, Ralf; Köppen, Kai; Sehner, Susanne; Kornmann, Frank; Gröbe, Alexander; Heiland, Max; Gerlach, Till

    2017-11-01

    Immediate loading of dental implants has been evolving into an appropriate procedure for the treatment of partially edentulous jaws. The purpose of this study was to evaluate the clinical success and radiological outcome of immediately and delayed loaded dental implants in anterior and premolar sites. In this retrospective study, data of 163 individuals requiring tooth removal with subsequent implant placement in anterior and premolar sites were analyzed. Implants were immediately loaded by provisional acrylic resin bridges or loaded with delay. Implants were followed up annually for up to 9 years including intraoral radiographs. A total of 285 implants in 163 patients were placed. 218 implants were immediately loaded and 67 implants with delay. Fifteen implants failed during the follow-up period resulting in survival rates of 94.5% for immediate loading and 95.5% for delayed loading. After an initial decrease of 0.3 mm in the first 12 months the marginal bone level remained stable. No statistically significant differences were found in marginal bone loss between immediately and delayed loaded implants (P = 0.518, 95% CI). Within the limits of this study, immediate loading of immediately subcrestally placed dental implants in anterior and premolar sites is a reliable treatment option for dental rehabilitation. Copyright © 2017 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  6. In-vitro study on the accuracy of a simple-design CT-guided stent for dental implants

    International Nuclear Information System (INIS)

    Huh, Young June; Choi, Bo Ram; Huh, Kyung Hoe; Yi, Won Jin; Heo, Min Suk; Lee, Sam Sun; Choi, Soon Chul

    2012-01-01

    An individual surgical stent fabricated from computed tomography (CT) data, called a CT-guided stent, would be useful for accurate installation of implants. The purpose of the present study was to introduce a newly developed CT-guided stent with a simple design and evaluate the accuracy of the stent placement. A resin template was fabricated from a hog mandible and a specially designed plastic plate, with 4 metal balls inserted in it for radiographic recognition, was attached to the occlusal surface of the template. With the surgical stent applied, CT images were taken, and virtual implants were placed using software. The spatial positions of the virtually positioned implants were acquired and implant guiding holes were drilled into the surgical stent using a specially designed 5-axis drilling machine. The surgical stent was placed on the mandible and CT images were taken again. The discrepancy between the central axis of the drilled holes on the second CT images and the virtually installed implants on the first CT images was evaluated. The deviation of the entry point and angulation of the central axis in the reference plane were 0.47±0.27 mm, 0.57±0.23 mm, and 0.64±0.16 degree, 0.57±0.15 degree, respectively. However, for the two different angulations in each group, the 20 degree angulation showed a greater error in the deviation of the entry point than did the 10 degree angulation. The CT-guided template proposed in this study was highly accurate. It could replace existing implant guide systems to reduce costs and effort.

  7. Learning and Memory Processes Following Cochlear Implantation:The Missing Piece of the Puzzle

    Directory of Open Access Journals (Sweden)

    David B. Pisoni

    2016-04-01

    Full Text Available At the present time, there is no question that cochlear implants work and often work very well in quiet listening conditions for many profoundly deaf children and adults. The speech and language outcomes data published over the last two decades document quite extensively the clinically significant benefits of cochlear implants. Although there now is a large body of evidence supporting the efficacy of cochlear implants as a medical intervention for profound hearing loss in both children and adults, there still remain a number of challenging unresolved clinical and theoretical issues that deal with the effectiveness of cochlear implants in individual patients that have not yet been successfully resolved. In this paper, we review recent findings on learning and memory, two central topics in the field of cognition that have been seriously neglected in research on cochlear implants. Our research findings on sequence learning, memory and organization processes, and retrieval strategies used in verbal learning and memory of categorized word lists suggests that basic domain-general learning abilities may be the missing piece of the puzzle in terms of understanding the cognitive factors that underlie the enormous individual differences and variability routinely observed in speech and language outcomes following cochlear implantation.

  8. Bilateral Poly Implant Prothèse Implant Rupture: An Uncommon Presentation

    Directory of Open Access Journals (Sweden)

    Peter Mallon

    2013-07-01

    Full Text Available Summary: A woman in her 50s underwent delayed bilateral Poly Implant Prothèse implant reconstruction following mastectomy for breast cancer. Symptoms of implant rupture developed 43 months after surgery with an erythematous rash on her trunk. The rash then spread to her reconstructed breast mounds. Initial ultrasound scan and magnetic resonance imaging were normal; however, subsequent magnetic resonance imaging demonstrated left implant rupture only. In theater, following removal of both implants, both were found to be ruptured. The rash on her trunk resolved within 3 weeks in the postoperative period. Chemical analyses of silicone in both implants confirmed a nonauthorized silicone source; in addition, the chemical structure was significantly different between the left and right implant, perhaps explaining the variation in presentation.

  9. Clinical and microbiological characteristics of peri-implantitis cases: a retrospective multicentre study.

    Science.gov (United States)

    Charalampakis, G; Leonhardt, Å; Rabe, P; Dahlén, G

    2012-09-01

    The aim of this study was to follow patient cases retrospectively in a longitudinal manner from the time of implant placement to the time they were diagnosed with peri-implant disease, and to identify associated clinical and microbiological features of peri-implant disease. A total of 281 patient cases were chosen from the archives of the Oral Microbiological Diagnostic Laboratory, Gothenburg, Sweden, based on bacterial samples taken from diseased implants. A form was designed and filled in separately for each case including data on patient, implant and disease profile. Most cases were severe peri-implantitis cases (91.4%). In 41.3% of the patients, peri-implantitis was developed early, already after having implants in function less than 4 years. The type of implant surface was significantly associated with the time in years implants were in function, before disease was developed (P < 0.05). The microbiological results by both culture and checkerboard analysis, although failed to fully correspond to the severity of the disease in terms of magnitude, proved to show that peri-implantitis is a polymicrobial anaerobic infection with increased number of AGNB (aerobic Gram-negative bacilli) in 18.6% of the patients. Peri-implantitis is a biological complication of implants in function that poses a threat to their long-term survival. It may develop earlier around implants with rough surfaces and it may represent a true infection. Microbiological sampling methods should be improved and uniformed so as to fully unveil the microbiological profile of the disease. © 2011 John Wiley & Sons A/S.

  10. Complications after cardiac implantable electronic device implantations

    DEFF Research Database (Denmark)

    Kirkfeldt, Rikke Esberg; Johansen, Jens Brock; Nohr, Ellen Aagaard

    2013-01-01

    Complications after cardiac implantable electronic device (CIED) treatment, including permanent pacemakers (PMs), cardiac resynchronization therapy devices with defibrillators (CRT-Ds) or without (CRT-Ps), and implantable cardioverter defibrillators (ICDs), are associated with increased patient...

  11. Radiographic implications of procedures involving cardiac implantable electronic devices (CIEDs – Selected aspects

    Directory of Open Access Journals (Sweden)

    Roman Steckiewicz

    2017-06-01

    Full Text Available Background: Some cardiac implantable electronic device (CIED implantation procedures require the use of X-rays, which is reflected by such parameters as total fluoroscopy time (TFT and dose-area product (DAP – defined as the absorbed dose multiplied by the area irradiated. Material and Methods: This retrospective study evaluated 522 CIED implantation (424 de novo and 98 device upgrade and new lead placement procedures in 176 women and 346 men (mean age 75±11 years over the period 2012–2015. The recorded procedure-related parameters TFT and DAP were evaluated in the subgroups specified below. The group of 424 de novo procedures included 203 pacemaker (PM and 171 implantable cardioverter-defibrillator (ICD implantation procedures, separately stratified by single-chamber and dual-chamber systems. Another subgroup of de novo procedures involved 50 cardiac resynchronization therapy (CRT devices. The evaluated parameters in the group of 98 upgrade procedures were compared between 2 subgroups: CRT only and combined PM and ICD implantation procedures. Results: We observed differences in TFT and DAP values between procedure types, with PM-related procedures showing the lowest, ICD – intermediate (with values for single-chamber considerably lower than those for dual-chamber systems and CRT implantation procedures – highest X-ray exposure. Upgrades to CRT were associated with 4 times higher TFT and DAP values in comparison to those during other upgrade procedures. Cardiac resynchronization therapy de novo implantation procedures and upgrades to CRT showed similar mean values of these evaluated parameters. Conclusions: Total fluoroscopy time and DAP values correlated progressively with CIED implantation procedure complexity, with CRT-related procedures showing the highest values of both parameters. Med Pr 2017;68(3:363–374

  12. Central venous catheters: detection of catheter complications and therapeutical options

    International Nuclear Information System (INIS)

    Gebauer, B.; Beck, A.; Wagner, H.J.; Vivantes-Kliniken, Hellersdorf und Prenzlauer Berg

    2008-01-01

    For modern medicine central venous catheters play an important role for diagnostic and therapeutic options. Catheter implantation, complication detection and therapy of catheter complications are an increasing demand for the radiologist. The review article provides an overview of different catheter types, their indications, advantages and disadvantages. Catheter malpositions are usually detectable in conventional X-ray. Most malpositions are correctable using interventional-radiological techniques. In addition therapeutical options for thrombotic complications (venous thrombosis, catheter occlusion, fibrin sheath) are discussed. In case of an infectious catheter complication, usually a catheter extraction and re-implantation is necessary

  13. Management of peri-implantitis

    Directory of Open Access Journals (Sweden)

    Jayachandran Prathapachandran

    2012-01-01

    Full Text Available Peri-implantitis is a site-specific infectious disease that causes an inflammatory process in soft tissues, and bone loss around an osseointegrated implant in function. The etiology of the implant infection is conditioned by the status of the tissue surrounding the implant, implant design, degree of roughness, external morphology, and excessive mechanical load. The microorganisms most commonly associated with implant failure are spirochetes and mobile forms of Gram-negative anaerobes, unless the origin is the result of simple mechanical overload. Diagnosis is based on changes of color in the gingiva, bleeding and probing depth of peri-implant pockets, suppuration, X-ray, and gradual loss of bone height around the tooth. Treatment will differ depending upon whether it is a case of peri-implant mucositis or peri-implantitis. The management of implant infection should be focused on the control of infection, the detoxification of the implant surface, and regeneration of the alveolar bone. This review article deals with the various treatment options in the management of peri-implantitis. The article also gives a brief description of the etiopathogenesis, clinical features, and diagnosis of peri-implantitis.

  14. Dose optimization of intra-operative high dose rate interstitial brachytherapy implants for soft tissue sarcoma

    Directory of Open Access Journals (Sweden)

    Jamema Swamidas

    2009-01-01

    Full Text Available Objective : A three dimensional (3D image-based dosimetric study to quantitatively compare geometric vs. dose-point optimization in combination with graphical optimization for interstitial brachytherapy of soft tissue sarcoma (STS. Materials and Methods : Fifteen consecutive STS patients, treated with intra-operative, interstitial Brachytherapy, were enrolled in this dosimetric study. Treatment plans were generated using dose points situated at the "central plane between the catheters", "between the catheters throughout the implanted volume", at "distances perpendicular to the implant axis" and "on the surface of the target volume" Geometrically optimized plans had dose points defined between the catheters, while dose-point optimized plans had dose points defined at a plane perpendicular to the implant axis and on the target surface. Each plan was graphically optimized and compared using dose volume indices. Results : Target coverage was suboptimal with coverage index (CI = 0.67 when dose points were defined at the central plane while it was superior when the dose points were defined at the target surface (CI=0.93. The coverage of graphically optimized plans (GrO was similar to non-GrO with dose points defined on surface or perpendicular to the implant axis. A similar pattern was noticed with conformity index (0.61 vs. 0.82. GrO were more conformal and less homogeneous compared to non-GrO. Sum index was superior for dose points defined on the surface of the target and relatively inferior for plans with dose points at other locations (1.35 vs. 1.27. Conclusions : Optimization with dose points defined away from the implant plane and on target results in superior target coverage with optimal values of other indices. GrO offer better target coverage for implants with non-uniform geometry and target volume.

  15. Material Science in Cervical Total Disc Replacement

    Directory of Open Access Journals (Sweden)

    Martin H. Pham

    2015-01-01

    Full Text Available Current cervical total disc replacement (TDR designs incorporate a variety of different biomaterials including polyethylene, stainless steel, titanium (Ti, and cobalt-chrome (CoCr. These materials are most important in their utilization as bearing surfaces which allow for articular motion at the disc space. Long-term biological effects of implanted materials include wear debris, host inflammatory immune reactions, and osteolysis resulting in implant failure. We review here the most common materials used in cervical TDR prosthetic devices, examine their bearing surfaces, describe the construction of the seven current cervical TDR devices that are approved for use in the United States, and discuss known adverse biological effects associated with long-term implantation of these materials. It is important to appreciate and understand the variety of biomaterials available in the design and construction of these prosthetics and the considerations which guide their implementation.

  16. Total knee arthroplasty

    DEFF Research Database (Denmark)

    Schrøder, Henrik M.; Petersen, Michael M.

    2016-01-01

    Total knee arthroplasty (TKA) is a successful treatment of the osteoarthritic knee, which has increased dramatically over the last 30 years. The indication is a painful osteoarthritic knee with relevant radiographic findings and failure of conservative measures like painkillers and exercise...... surgeon seems to positively influence the rate of surgical complications and implant survival. The painful TKA knee should be thoroughly evaluated, but not revised except if a relevant indication can be established. The most frequent indications for revision are: aseptic loosening, instability, infection...

  17. Survival of dental implants in patients with Down syndrome: A case series.

    Science.gov (United States)

    Limeres Posse, Jacobo; López Jiménez, Julian; Ruiz Villandiego, José C; Cutando Soriano, Antonio; Fernández Feijoo, Javier; Linazasoro Elorza, Maialen; Diniz Freitas, Márcio; Diz Dios, Pedro

    2016-12-01

    The need for tooth replacement in individuals with Down syndrome (DS) is explained by the high prevalence of dental agenesis and by the premature loss of teeth through severe periodontal disease. Dental implants may be the dental procedure of choice in some of these patients. The purpose of this clinical study was to analyze dental implant survival in a series of patients with DS. This was a multicenter, retrospective, observational study. Information on patients was gathered using a standardized questionnaire designed specifically for this study, including personal details, oral health status, information on the surgical and prosthetic phases, and follow-up visits. The questionnaire was sent to centers registered with the research network of the Spanish Society of Special Needs Dentistry (SEOENE). Patients with DS aged 18 years or older were included in the study if they had at least 1 dental implant and the corresponding prosthesis and had been followed up for at least a year. The study population was formed of 25 adult patients (13 men and 12 women) aged between 19 and 60 years. The interventions were performed by 5 different dental surgeons, usually under general anesthesia or deep sedation (n=17 patients). A total of 73 implants were inserted, 30 in the maxilla and 43 in the mandible, most commonly in the anterior region (n=51). The mean time to loading the implants was 4.1 ±1.3 months after surgery (range, 1 to 7 months). All patients completed prosthetic rehabilitation; the most frequent design used was the single fixed prosthesis (n=13 patients). A total of 17 (23.2%) implants failed in 8 (32%) patients; the majority (n=14 implants) failed in the postsurgical period before implant loading. The distribution by patients was 1 implant failure in 6 patients, 3 failures in 1 patient, and 8 failures in 1 patient. Dental implant survival is lower in individuals with DS than in the general population. The reasons for early implant failure in these patients have

  18. Experimental study on bone tissue reaction around HA implants radiated after implantation

    International Nuclear Information System (INIS)

    Kudo, Masato; Matsui, Yoshiro; Tamura, Sayaka; Chen, Xuan; Uchida, Haruo; Mori, Kimie; Ohno, Kohsuke; Michi, Ken-ichi

    1998-01-01

    This study was conducted to investigate histologically and histomorphometrically the tissue reaction around hydroxylapatite (HA) implants that underwent irradiation in 3 different periods in the course of bone healing after implantation. The cylindrical high-density HA implants were implanted in 48 Japanese white rabbit mandibles. A single 15 Gy dose was applied to the mandible 5, 14, or 28 days after implantation. The rabbits were sacrificed 7, 14, 28, and 90 days after irradiation. Nonirradiated rabbits were used as controls. CMR, labeling with tetracycline and calcein, and non-decalcified specimens stained with toluidine blue were used for histological analyses and histomorphometric measurements. The results were as follows: In the rabbits irradiated 5 days after implantation, the HA-bone contact was observed later than that in the controls and the bone-implant contact surface ratio was lower than that in the controls at examination because necrosis of the newly-formed bone occurred just after irradiation. HA-bone contact of the rabbits irradiated 14 and 28 days after implantation was similar to that of the controls. And, bone remodeling was suppressed in rabbits of each group sacrificed at 90 days after irradiation. The results suggested that a short interval between implantation and irradiation causes direct contact between HA implant and bone and a long lapse of time before irradiation hardly affects the bone-implant contact, but delays bone remodeling. Therefore, it is necessary to prevent overloading the HA implants irradiated after implantation and pay utmost attention to conditions around the bone-implant contact. (author)

  19. One-stage explant-implant procedure of exposed porous orbital implants

    DEFF Research Database (Denmark)

    Toft, Peter B; Rasmussen, Marie L Roed; Prause, Jan Ulrik

    2011-01-01

    Purpose:  To investigate the risks of implant exposure after a combined explant-implant procedure in patients with an exposed porous orbital implant. Methods:  Twenty-four consecutive patients who had a combined explant-implant procedure of an exposed hydroxyapatite (21) or porous polyethylene (3...... at the same procedure in sockets without profound signs of infection. The procedure carries a possible risk of poor motility....

  20. Two-stage implant systems.

    Science.gov (United States)

    Fritz, M E

    1999-06-01

    Since the advent of osseointegration approximately 20 years ago, there has been a great deal of scientific data developed on two-stage integrated implant systems. Although these implants were originally designed primarily for fixed prostheses in the mandibular arch, they have been used in partially dentate patients, in patients needing overdentures, and in single-tooth restorations. In addition, this implant system has been placed in extraction sites, in bone-grafted areas, and in maxillary sinus elevations. Often, the documentation of these procedures has lagged. In addition, most of the reports use survival criteria to describe results, often providing overly optimistic data. It can be said that the literature describes a true adhesion of the epithelium to the implant similar to adhesion to teeth, that two-stage implants appear to have direct contact somewhere between 50% and 70% of the implant surface, that the microbial flora of the two-stage implant system closely resembles that of the natural tooth, and that the microbiology of periodontitis appears to be closely related to peri-implantitis. In evaluations of the data from implant placement in all of the above-noted situations by means of meta-analysis, it appears that there is a strong case that two-stage dental implants are successful, usually showing a confidence interval of over 90%. It also appears that the mandibular implants are more successful than maxillary implants. Studies also show that overdenture therapy is valid, and that single-tooth implants and implants placed in partially dentate mouths have a success rate that is quite good, although not quite as high as in the fully edentulous dentition. It would also appear that the potential causes of failure in the two-stage dental implant systems are peri-implantitis, placement of implants in poor-quality bone, and improper loading of implants. There are now data addressing modifications of the implant surface to alter the percentage of

  1. Modifications of the hydriding kinetics of a metallic surface, using ion implantation

    International Nuclear Information System (INIS)

    Crusset, D.

    1992-10-01

    Uranium reacts with hydrogen to form an hydride: this reaction leads to the total destruction of the material. To modify the reactivity of an uranium surface towards hydrogen, ion implantation was selected, among surface treatments techniques. Four elements (carbon, nitrogen, oxygen, sulfur) were implanted to different doses. The results show a modification of the hydriding mechanism and a significant increase in the reaction induction times, notably at high implantation doses. Several techniques (SIMS, X-rays phases analysis and residual stresses determination) were used to characterize the samples and understand the different mechanisms involved

  2. Impaction grafting in the femur in cementless modular revision total hip arthroplasty: a descriptive outcome analysis of 243 cases with the MRP-TITAN revision implant

    Directory of Open Access Journals (Sweden)

    Wimmer Matthias D

    2013-01-01

    Full Text Available Abstract Background We present a descriptive and retrospective analysis of revision total hip arthroplasties (THA using the MRP-TITAN stem (Peter Brehm, Weisendorf, GER with distal diaphyseal fixation and metaphyseal defect augmentation. Our hypothesis was that the metaphyseal defect augmentation (Impaction Bone Grafting improves the stem survival. Methods We retrospectively analyzed the aggregated and anonymized data of 243 femoral stem revisions. 68 patients with 70 implants (28.8% received an allograft augmentation for metaphyseal defects; 165 patients with 173 implants (71.2% did not, and served as controls. The mean follow-up was 4.4 ± 1.8 years (range, 2.1–9.6 years. There were no significant differences (p > 0.05 between the study and control group regarding age, body mass index (BMI, femoral defects (types I-III as described by Paprosky, and preoperative Harris Hip Score (HHS. Postoperative clinical function was evaluated using the HHS. Postoperative radiologic examination evaluated implant stability, axial implant migration, signs of implant loosening, periprosthetic radiolucencies, as well as bone regeneration and resorption. Results There were comparable rates of intraoperative and postoperative complications in the study and control groups (p > 0.05. Clinical function, expressed as the increase in the postoperative HHS over the preoperative score, showed significantly greater improvement in the group with Impaction Bone Grafting (35.6 ± 14.3 vs. 30.8 ± 15.8; p ≤ 0.05. The study group showed better outcome especially for larger defects (types II C and III as described by Paprosky and stem diameters ≥ 17 mm. The two groups did not show significant differences in the rate of aseptic loosening (1.4% vs. 2.9% and the rate of revisions (8.6% vs. 11%. The Kaplan-Meier survival for the MRP-TITAN stem in both groups together was 93.8% after 8.8 years. [Study group 95.7% after 8.54 years ; control group 93

  3. A prospective 5-year study of fixed partial prostheses supported by implants with machined and TiO2-blasted surface

    DEFF Research Database (Denmark)

    Gotfredsen, K; Karlsson, U

    2001-01-01

    PURPOSE: The aim of the present study was to evaluate whether there was a difference between machined and TiO(2)-blasted implants regarding survival rate and marginal bone loss during a 5-year observation period. MATERIALS AND METHODS: A total of 133 implants (Astra Tech Dental Implants; Astra Tech...... AB, Mölndal, Sweden) were placed in 50 patients at 6 centers in 4 Scandinavian countries. Forty-eight implants were installed in the maxilla and 85 implants in the mandible. A randomization and a stratification were done, so that each fixed partial prosthesis was supported by at least 1 machined...... and 1 TiO(2)-blasted implant. The implant-supported fixed partial prostheses (ISFPP) were fabricated within 2 months after postoperative healing. A total of 52 ISFPP (17 maxillary, 35 mandibular) were inserted. The patients were clinically examined once a year for 5 years. At the annual follow...

  4. Written Language Ability in Mandarin-Speaking Children with Cochlear Implants.

    Science.gov (United States)

    Wu, Che-Ming; Ko, Hui-Chen; Chen, Yen-An; Tsou, Yung-Ting; Chao, Wei-Chieh

    2015-01-01

    Objectives. To examine narrative writing in cochlear implant (CI) children and understand the factors associated with unfavorable outcomes. Materials and Methods. Forty-five CI children in grades 2-6 participated in this study. They received CIs at 4.1 ± 2.1 years of age and had used them for 6.5 ± 2.7 years. A story-writing test was conducted and scored on 4 subscales: Total Number of Words, Words per Sentence, Morphosyntax, and Semantics. Scores more than 1.5 SD lower than the mean of the normal-hearing normative sample were considered problematic. Language and speech skills were examined. Results. Significantly more implanted students were problematic on "Total Number of Words" (p < 0.001), "Words per Sentence" (p = 0.049), and "Semantics" (p < 0.001). Poorer receptive language and auditory performance were independently associated with problematic "Total Number of Words" (R (2) = 0.489) and "Semantics" (R (2) = 0.213), respectively. "Semantics" problem was more common in lower graders (grades 2-4) than in higher graders (grades 5-6; p = 0.016). Conclusion. Implanted children tend to write stories that are shorter, worse-organized, and without a plot, while formulating morphosyntactically correct sentences. Special attention is required on their auditory and language performances, which could lead to written language problems.

  5. Axial displacement of abutments into implants and implant replicas, with the tapered cone-screw internal connection, as a function of tightening torque.

    Science.gov (United States)

    Dailey, Bruno; Jordan, Laurence; Blind, Olivier; Tavernier, Bruno

    2009-01-01

    The passive fit of a superstructure on implant abutments is essential to success. One source of error when using a tapered cone-screw internal connection may be the difference between the tightening torque level applied to the abutments by the laboratory technician compared to that applied by the treating clinician. The purpose of this study was to measure the axial displacement of tapered cone-screw abutments into implants and their replicas as a function of the tightening torque level. Twenty tapered cone-screw abutments were selected. Two groups were created: 10 abutments were secured into 10 implants, and 10 abutments were secured into 10 corresponding implant replicas. Each abutment was tightened in increasing increments of 5 Ncm, from 0 Ncm to 45 Ncm, with a torque controller. The length of each sample was measured repeatedly with an Electronic Digital Micrometer. The mean axial displacement for the implant group and the replica group was calculated. The data were analyzed by the Mann-Whitney and Spearman tests. For both groups, there was always an axial displacement of the abutment upon each incremental application of torque. The mean axial displacement values varied between 7 and 12 microm for the implant group and between 6 and 21 microm for the replica group at each 5-Ncm increment. From 0 to 45 Ncm, the total mean axial displacement values were 89 microm for the implant group and 122 microm for the replica group. There was a continuous axial displacement of the abutments into implants and implant replicas when the applied torque was raised from 0 to 45 Ncm. Torque applied above the level recommended by the manufacturer increased the difference in displacement between the two groups.

  6. Fracaso en los implantes dentales: Fibrointegración. Reporte de caso clínico

    Directory of Open Access Journals (Sweden)

    Iris Luz Santís Chamorro

    2014-06-01

    Full Text Available  ResumenLa rehabilitación con implantes dentales en los pacientes con edentulismo parcial o total posee amplias indicaciones que se ven limitadas por factores anatómicos y biológicos. La oseointegración surge como un hecho descubierto entre la adaptación biológica del hueso a la superficie del titanio del implante (interfase hueso-implante por lo que se afirma que el motivo de fracaso de la mayoría de los sistemas de implantes es que éstos se encapsulen en un tejido de cicatrización fibroso (fibrointegración mal diferenciado lo que crea movilidad, que lleva a reacciones en la mucosa y finalmente a la pérdida. El objetivo del presente artículo es promover la presentación de casos clínicos de pacientes con fracaso de implantes dentales, con el ánimo de esclarecer las posibles causas y los factores coadyuvantes de dicho fracaso, y así mejorar los resultados en implantología. (Duazary 2008; 115-120AbstractThe rehabilitation with dental implants in the patients with partial absence or total of teeth possesses extensive indications that are seen limited by biological and anatomical factors. The oseointegration arises like a discovered fact among the biological adaptation of the bone to the surface of the titanic of the implant (interface bone-implant for which it is affirmed that the motive of failure of the majority of the systems of implants is that these it self envelop in a scar formation of fibrous tissue (Fibrointegration badly differentiated what creates mobility, that carries to reactions in the mucous membrane and finally to the loss. The objective of the present article is to promote the presentation of patients' clinical cases with failure of dental implants, with the intention of clarifying the possible reasons and the helping factors of the above mentioned failure, and this way to improve the results in implantology.Key Words: Fibrointegration; oseointegration; dentals implants; interface; implants failure.

  7. The Pathology of Orthopedic Implant Failure Is Mediated by Innate Immune System Cytokines

    OpenAIRE

    Landgraeber, Stefan; Jäger, Marcus; Jacobs, Joshua J.; Hallab, Nadim James

    2014-01-01

    All of the over 1 million total joint replacements implanted in the US each year are expected to eventually fail after 15–25 years of use, due to slow progressive subtle inflammation at the bone implant interface. This inflammatory disease state is caused by implant debris acting, primarily, on innate immune cells, that is, macrophages. This slow progressive pathological bone loss or “aseptic loosening” is a potentially life-threatening condition due to the serious complications in older peop...

  8. Impact of implant design on primary stability of orthodontic mini-implants.

    Science.gov (United States)

    Wilmes, Benedict; Ottenstreuer, Stephanie; Su, Yu-Yu; Drescher, Dieter

    2008-01-01

    Skeletal anchorage with mini-implants has greatly broadened the treatment possibilities in orthodontics over the last few years. To reduce implant failure rates, it is advisable to obtain adequate primary stability. The aim of this study was to quantitatively analyze the impact of implant design and dimension on primary stability. Forty-two porcine iliac bone segments were prepared and embedded in resin. To evaluate the primary stability, we documented insertion torques of the following mini-implants: Aarhus Screw, AbsoAnchor, LOMAS, Micro-Anchorage-System, ORLUS and Spider Screw. In each bone, five Dual Top Screws were inserted for reference purposes to achieve comparability among the specimens. We observed wide variation in insertion torques and hence primary stability, depending on mini-implant design and dimension; the great impact that mini-implant diameter has on insertion torques was particularly conspicuous. Conical mini-implants achieved higher primary stabilities than cylindrical designs. The diameter and design of the mini-implant thread have a distinctive impact on primary stability. Depending on the region of insertion and local bone quality, the choice of the mini-implant design and size is crucial to establish sufficient primary stability.

  9. Replacement of a hopeless maxillary central incisor: a technique for the fabrication of an immediate implant-supported interim restoration.

    Science.gov (United States)

    Graiff, Lorenzo; Vigolo, Paolo

    2012-04-01

    Placement of a dental implant and an interim restoration in the esthetic zone immediately following tooth extraction is now a common procedure. However, in such clinical situations, the fabrication of an appropriate interim restoration may be challenging. The aim of this article is to present a technique for modifying the extracted tooth so it can be used as an implant-supported interim restoration.

  10. Three-dimensional accuracy of a digitally coded healing abutment implant impression system.

    Science.gov (United States)

    Ng, Simon D; Tan, Keson B; Teoh, K H; Cheng, Ansgar C; Nicholls, Jack I

    2014-01-01

    This study examined the three-dimensional (3D) accuracy of the Encode Impression System (EN) in transferring the locations of two implants from master models to test models and compared this to the direct impression (DI) technique. The effect of interimplant angulation on the 3D accuracy of both impression techniques was also evaluated. Seven sectional polymethyl methacrylate mandibular arch master models were fabricated with implants in the first premolar and first molar positions. The implants were placed parallel to each other or angulated mesiodistally or buccolingually with total divergent angles of 10, 20, or 30 degrees. Each master model was secured onto an aluminum block containing a gauge block, which defined the local coordinate references. Encode healing abutments were attached to the implants before impressions were made for the EN test models; pickup impression copings were attached for the DI test models. For the seven test groups of each impression technique, a total of 70 test models were fabricated (n = 5). The EN test models were sent to Biomet 3i for implant analog placement. The centroid of each implant or implant analog and the angular orientation of the long axis relative to the x- and y-axes were measured with a coordinate measuring machine. Statistical analyses were performed. Impression technique had a significant effect on y distortion, global linear distortion, and absolute xz and yz angular distortions. Interimplant angulation had significant effects on x and y distortions. However, neither impression technique nor interimplant angulation had a significant effect on z distortion. Distortions were observed with both impression techniques. However, the results suggest that EN was less accurate than DI.

  11. Revision of failed shoulder hemiarthroplasty to reverse total arthroplasty: analysis of 157 revision implants.

    Science.gov (United States)

    Merolla, Giovanni; Wagner, Eric; Sperling, John W; Paladini, Paolo; Fabbri, Elisabetta; Porcellini, Giuseppe

    2018-01-01

    There remains a paucity of studies examining the conversion of failed hemiarthroplasty (HA) to reverse total shoulder arthroplasty (RTSA). Therefore, the purpose of this study was to examine a large series of revision HA to RTSA. A population of 157 patients who underwent conversion of a failed HA to a revision RTSA from 2006 through 2014 were included. The mean follow-up was 49 months (range, 24-121 months). The indications for revision surgery included instability with rotator cuff insufficiency (n = 127) and glenoid wear (n = 30); instability and glenoid wear were associated in 38 cases. Eight patients with infection underwent 2-stage reimplantation. Patients experienced significant improvements in their preoperative to postoperative pain and shoulder range of motion (P surgeries, secondary to glenoid component loosening (n = 3), instability (n = 3), humeral component disassembly (n = 2), humeral stem loosening (n = 1), and infection (n = 2). Implant survivorship was 95.5% at 2 years and 93.3% at 5 years. There were 4 reoperations including axillary nerve neurolysis (n = 2), heterotopic ossification removal (n = 1), and hardware removal for rupture of the metal cerclage for an acromial fracture (n = 1). At final follow-up, there were 5 "at-risk" glenoid components. Patients experience satisfactory pain relief and recovery of reasonable shoulder function after revision RTSA from a failed HA. There was a relatively low revision rate, with glenoid loosening and instability being the most common causes. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  12. The use of tungsten as a chronically implanted material

    Science.gov (United States)

    Shah Idil, A.; Donaldson, N.

    2018-04-01

    This review paper shows that tungsten should not generally be used as a chronically implanted material. The metal has a long implant history, from neuroscience, vascular medicine, radiography, orthopaedics, prosthodontics, and various other fields, primarily as a result of its high density, radiopacity, tensile strength, and yield point. However, a crucial material criterion for chronically implanted metals is their long-term resistance to corrosion in body fluids, either by inherently noble metallic surfaces, or by protective passivation layers of metal oxide. The latter is often assumed for elemental tungsten, with references to its ‘inertness’ and ‘stability’ common in the literature. This review argues that in the body, metallic tungsten fails this criterion, and will eventually dissolve into the soluble hexavalent form W6+, typically represented by the orthotungstate WO42- (monomeric tungstate) anion. This paper outlines the metal’s unfavourable corrosion thermodynamics in the human physiological environment, the chemical pathways to either metallic or metal oxide dissolution, the rate-limiting steps, and the corrosion-accelerating effects of reactive oxidising species that the immune system produces post-implantation. Multiple examples of implant corrosion have been reported, with failure by dissolution to varying extents up to total loss, with associated emission of tungstate ions and elevated blood serum levels measured. The possible toxicity of these corrosion products has also been explored. As the field of medical implants grows and designers explore novel solutions to medical implant problems, the authors recommend the use of alternative materials.

  13. Anaplastic large cell lymphoma associated with breast implants

    Directory of Open Access Journals (Sweden)

    Vid Bajuk

    2017-02-01

    Full Text Available An increasing number of women worldwide decide for esthetic correction of breasts with silicone implants and post-cancer breast reconstruction with tissue expanders and silicone breast implants. It is estimated that more than 10 million women around the globe have them. Tere are approximately 200 known cases of patients with anaplastic large cell lymphoma (ALCL linked with silicone breast implants reported in medical literature. ALCL is a rare disease with an annual incidence of 0.1–0.3/100 000 women with breast silicone implants. In the presence of clinical signs, physician should also consider this rare form of ALCL in differential diagnosis. Patients are on average 50 years old. Long afer implantation surgery, the patient may experience breast swelling, pain and/or asymmetry. In diagnostics, ultrasound and cytological examination are required. During ultrasound examination fluid formation (seroma or solid tumor mass can be detected. Treatment is individualized. Due to tumor nature, implant resection and total capsulectomy are usually indicated; also, chemo- and radiotherapy might rarely be required. Five-year survival rate depends on tumor form and correlates well with clinical fndings of seroma or solid mass. In the more frequent form, seroma, fve-year survival rate is 100 %, while in the case of solid tumor mass fve-year survival rate is 75 %. The rarity of this disease makes it difficult to diagnose, but nevertheless, early detection and treatment are important for better recovery.

  14. Silver-based antibacterial surfaces for bone implants

    NARCIS (Netherlands)

    Necula, B.S.

    2013-01-01

    Total hip arthroplasty (THA) is the most effective and safest method for treating severe degenerative, post-traumatic and other diseases of the joints. With an aging population that is increasingly active, the use of biomedical implants will continue to rise. It is estimated that more than 1,000,000

  15. Patient Perception of Value in Bundled Payments for Total Joint Arthroplasty.

    Science.gov (United States)

    Schwartz, Adam J; Fraser, James F; Shannon, Allison M; Jackson, Nikki T; Raghu, T S

    2016-12-01

    A central concern for providers in a bundled payment model is determining how the bundle is distributed. Prior studies have shown that current reimbursement rates are often not aligned with patients' values. While willingness-to-pay (WTP) surveys are perhaps useful in a fee-for-service arrangement to determine overall reimbursement, the percentage of payment distribution might be as or more important in a bundled payment model. All patients undergoing primary total joint arthroplasty by a single surgeon were offered participation in a preoperative WTP survey. At a minimum 3 months postoperatively, patients were mailed instructions for an online follow-up survey asking how they would allocate a hypothetical bonus payment. From January through December 2014, 45 patients agreed to participate in the preoperative WTP survey. Twenty patients who were minimum 3 months postoperative also completed the follow-up survey. Patients valued total knee and hip arthroplasty at $28,438 (95% confidence interval [CI]: $20,551-36,324) and $39,479 (95% CI: $27,848-$51,112), respectively. At 3 months postoperatively, patients distributed a hypothetical bonus payment 55.5% to the surgeon (95% CI: 47.8%-63.1%), 38% to the hospital (95% CI: 30.3%-45.7%), and 6.5% (95% CI: -1.2% to 14.2%) to the implant manufacturer (P < .001). The data suggest that total joint arthroplasty patients have vastly different perceptions of payment distributions than what actually exists. In contrast to the findings of this study, the true distribution of payments for an episode of care averages 65% to the hospital, 27% to the implant manufacturer, and 8% to the surgeon. While many drivers of payment distribution exist, this study suggests that patients would allocate a larger proportion of a bundled payment to surgeons than is currently disbursed. This finding may also provide a plausible explanation for patients' consistent overestimation of surgeon reimbursements. Copyright © 2016 Elsevier Inc. All rights

  16. Deuterium trapping in ion implanted and co-deposited beryllium oxide layers

    International Nuclear Information System (INIS)

    Markin, A.V.; Gorodetsky, A.E.; Zakharov, A.P.; Wu, C.H.

    2000-01-01

    Deuterium trapping in beryllium oxide films irradiated with 400 eV D ions has been studied by thermal desorption spectroscopy (TDS). It has been found that for thermally grown BeO films implanted in the range 300 - 900 K the total deuterium retention doesn't depend whereas TDS spectra do markedly on irradiation temperature. For R.T. implantation the deuterium is released in a wide range from 500 to 1100 K. At implantation above 600 K the main portion of retained deuterium is released in a single peak centered at about 1000 K. The similar TDS peak is measured for D/BeO co-deposited layer. In addition we correlate our implantation data on BeO with the relevant data on beryllium metal and carbon. The interrelations between deuterium retention and microstructure are discussed. (orig.)

  17. Implantation of β-emitters on biomedical implants: 32 P isotropic ion implantation using a coaxial plasma reactor

    International Nuclear Information System (INIS)

    Fortin, M.A.; Paynter, R.W.; Sarkissian, A.; Stansfield, B.L.; Terreault, B.; Dufresne, V.

    2003-01-01

    The development of endovascular brachytherapy and the treatment of certain types of cancers (liver, lung, prostate) often require the use of beta-emitters, sometimes in the form of radioisotope-implanted devices. Among the most commonly used isotopes figures 32 P, a pure beta-emitter (maximum energy: 1.7 MeV), of which the path in biological tissues is of a few cm, restricting the impact of electron bombardment to the immediate environment of the implant. Several techniques and processes have been tried to elaborate surfaces and devices showing strongly bonded, or implanted 32 P. Anodizing, vapor phase deposition, grafting of oligonucleotides, as well as ion implantation processes have been investigated by several research groups as methods to implant beta-radioisotopes into surfaces. A coaxial plasma reactor was developed at INRS to implant radioisotopes into cylindrical metallic objects, such as coronary stents commonly used in angioplasty procedures. The dispersion of 32 P atoms on the interior surfaces of the chamber can be investigated using radiographs, contributing to image the plasma ion transport mechanisms that guide the efficiency of the implantation procedure. The amount of radioactivity on the wall liner, on the internal components, and on the biomedical implants are quantified using a surface barrier detector. A comparative study establishes a relationship between the gray scale of the radiographs, and dose measurements. A program was developed to convert the digitized images into maps showing surface dose density in mCi/cm 2 . An integration process allows the quantification of the doses on the walls and components of the reactor. Finally, the resulting integral of the 32 P dose is correlated to the initial amount of radioactivity inserted inside the implanter before the dismantling procedure. This method could be introduced as a fast and reliable way to test, qualify and assess the amount of radioactivity present on the as-produced implants

  18. The Pathology of Orthopedic Implant Failure Is Mediated by Innate Immune System Cytokines

    Directory of Open Access Journals (Sweden)

    Stefan Landgraeber

    2014-01-01

    Full Text Available All of the over 1 million total joint replacements implanted in the US each year are expected to eventually fail after 15–25 years of use, due to slow progressive subtle inflammation at the bone implant interface. This inflammatory disease state is caused by implant debris acting, primarily, on innate immune cells, that is, macrophages. This slow progressive pathological bone loss or “aseptic loosening” is a potentially life-threatening condition due to the serious complications in older people (>75 yrs of total joint replacement revision surgery. In some people implant debris (particles and ions from metals can influence the adaptive immune system as well, giving rise to the concept of metal sensitivity. However, a consensus of studies agrees that the dominant form of this response is due to innate reactivity by macrophages to implant debris where both danger (DAMP and pathogen (PAMP signalling elicit cytokine-based inflammatory responses. This paper discusses implant debris induced release of the cytokines and chemokines due to activation of the innate (and the adaptive immune system and the subsequent formation of osteolysis. Different mechanisms of implant-debris reactivity related to the innate immune system are detailed, for example, danger signalling (e.g., IL-1β, IL-18, IL-33, etc., toll-like receptor activation (e.g., IL-6, TNF-α, etc., apoptosis (e.g., caspases 3–9, bone catabolism (e.g., TRAP5b, and hypoxia responses (Hif1-α. Cytokine-based clinical and basic science studies are in progress to provide diagnosis and therapeutic intervention strategies.

  19. The Pathology of Orthopedic Implant Failure Is Mediated by Innate Immune System Cytokines

    Science.gov (United States)

    Landgraeber, Stefan; Jäger, Marcus; Jacobs, Joshua J.; Hallab, Nadim James

    2014-01-01

    All of the over 1 million total joint replacements implanted in the US each year are expected to eventually fail after 15–25 years of use, due to slow progressive subtle inflammation at the bone implant interface. This inflammatory disease state is caused by implant debris acting, primarily, on innate immune cells, that is, macrophages. This slow progressive pathological bone loss or “aseptic loosening” is a potentially life-threatening condition due to the serious complications in older people (>75 yrs) of total joint replacement revision surgery. In some people implant debris (particles and ions from metals) can influence the adaptive immune system as well, giving rise to the concept of metal sensitivity. However, a consensus of studies agrees that the dominant form of this response is due to innate reactivity by macrophages to implant debris where both danger (DAMP) and pathogen (PAMP) signalling elicit cytokine-based inflammatory responses. This paper discusses implant debris induced release of the cytokines and chemokines due to activation of the innate (and the adaptive) immune system and the subsequent formation of osteolysis. Different mechanisms of implant-debris reactivity related to the innate immune system are detailed, for example, danger signalling (e.g., IL-1β, IL-18, IL-33, etc.), toll-like receptor activation (e.g., IL-6, TNF-α, etc.), apoptosis (e.g., caspases 3–9), bone catabolism (e.g., TRAP5b), and hypoxia responses (Hif1-α). Cytokine-based clinical and basic science studies are in progress to provide diagnosis and therapeutic intervention strategies. PMID:24891761

  20. Five year survival analysis of an oxidised zirconium total knee arthroplasty.

    Science.gov (United States)

    Holland, Philip; Santini, Alasdair J A; Davidson, John S; Pope, Jill A

    2013-12-01

    Zirconium total knee arthroplasties theoretically have a low incidence of failure as they are low friction, hard wearing and hypoallergenic. We report the five year survival of 213 Profix zirconium total knee arthroplasties with a conforming all polyethylene tibial component. Data was collected prospectively and multiple strict end points were used. SF12 and WOMAC scores were recorded pre-operatively, at three months, at twelve months, at 3 years and at 5 years. Eight patients died and six were "lost to follow-up". The remaining 199 knees were followed up for five years. The mean WOMAC score improved from 56 to 35 and the mean SF12 physical component score improved from 28 to 34. The five year survival for failure due to implant related reasons was 99.5% (95% CI 97.4-100). This was due to one tibial component becoming loose aseptically in year zero. Our results demonstrate that the Profix zirconium total knee arthroplasty has a low medium term failure rate comparable to the best implants. Further research is needed to establish if the beneficial properties of zirconium improve long term implant survival. Copyright © 2012 Elsevier B.V. All rights reserved.

  1. The use of bone block allografts in sinus augmentation, followed by delayed implant placement: A case series

    Directory of Open Access Journals (Sweden)

    Eurico D Aloja

    2013-01-01

    Full Text Available Purpose: This article reports the clinical outcomes observed in a large number of patients receiving block bone allograft used for sinus augmentation and delayed implant placement. Patients and Methods: In total, 28 patients (13 males with a mean age of 49.8 ± 10.1 years (range: 33-67 years were included in this case series. All selected patients suffered from severe alveolar ridge atrophy in the posterior maxilla and required bone augmentation procedures, followed by implant placement after 6 months. All patients were followed for 18 months after the grafting, with scheduled monthly visits and/or more frequent visits if required. The survival rates for both the bone blocks and placed implants were then evaluated. Results: A total of 42 blocks and 90 implants were placed. Only one bone graft and 5 implants failed; the survival rate was 97.2% and 95.5% for the bone grafts and implants, respectively. The graft failed due to the onset of post-surgical infectious sinusitis, while in some patients′ implants showed absence of osteointegration at the end of the healing phase. Of note, all failed implants were observed in heavy smokers; in all other patients, blocks and implants were successful. Conclusions: This preliminary case series suggests that the grafting of bone allograft followed by delayed implant placement may be a promising strategy for sinus augmentation. More extended and larger follow-up studies are needed to confirm this preliminary data.

  2. Success of dental implants in vascularised fibular osteoseptocutaneous flaps used as onlay grafts after marginal mandibulectomy.

    Science.gov (United States)

    Chang, Y-M; Pan, Y-H; Shen, Y-F; Chen, J-K; ALDeek, N F; Wei, F-C

    2016-12-01

    We have evaluated the survival of dental implants placed in vascularised fibular flap onlay grafts placed over marginal mandibulectomies and the effects on marginal bone loss of different types of soft tissue around implants under functional loading. From 2001-2009 we studied a total of 11 patients (1 woman and10 men), three of whom had had ameloblastoma and eight who had had squamous cell carcinomas resected. A total of 38 dental implants were placed either at the time of transfer of the vascularised fibular ostoseptocutaneous flaps (nine patients with 30 implants) or secondarily (two patients with eight implants). Four patients were given palatal mucosal grafts to replace intraoral skin flaps around the dental implants (n=13), and the other seven had the skin flaps around the dental implants thinned (n=25) at the second stage of implantation of the osteointegrated teeth. All vascularised fibular osteoseptocutaneous flaps were successfully transferred, and all implants survived a mean (range) of 73 (33-113) months after occlusal functional loading. The mean (SD) marginal bone loss was 0.5 (0.3) mm on both mesial and distal sides in patients who had palatal mucosal grafts, but 1.8 (1.6) mm, and 1.7 (1.5) mm, respectively, on the mesial and distal sides in the patients who had had thinning of their skin flaps. This difference is significant (p=0.008) with less resorption of bone in the group who had palatal mucosal grafts. Palatal mucosa around the implants helps to reduce resorption of bone after functional loading of implants. Copyright © 2016 The British Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  3. [Susceptibility to infections and behavior of stainless steel : Comparison with titanium implants in traumatology].

    Science.gov (United States)

    Haubruck, Patrick; Schmidmaier, Gerhard

    2017-02-01

    Despite modern treatment options, implant-associated infections (IAI) remain a severe and challenging complication in the treatment of trauma patients. Almost 30 years after the introduction of implants made of titanium alloy into the treatment of trauma patients, there is still no uniform consensus regarding the clinical benefit of titanium alloy in the context of patients with IAI. We sought to determine if implants made of titanium alloy have been proven to be less susceptible regarding IAI in contrast to implants made of stainless steel. A review of the current literature on IAI in association with the utilized implant material was conducted. Relevant articles from the years 1995 to 2016 were searched in the PubMed database. A total of 183 articles were identified and all abstracts were reviewed for relevance. A total of 14 articles met the inclusion criteria and were stratified according to the level of evidence and furthermore evaluated regarding the influence of the implant material on IAI. Considerable debate remains concerning the influence of the implant material on the susceptibility to IAI; however, the available literature shows that despite slight tendencies, there is no proof of titanium alloy being favorable in the susceptibility to IAI. Furthermore, the literature shows that the design of plates for osteosynthesis might influence IAI. In particular, plates that cause less soft tissue damage and preserve perfusion of the periosteum proved to be beneficial regarding IAI.

  4. Revision washout decreases implant capsule tissue culture positivity: a multicenter study.

    Science.gov (United States)

    Henry, Gerard D; Carson, Culley C; Wilson, Steven K; Wiygul, Jeremy; Tornehl, Chris; Cleves, Mario A; Simmons, Caroline J; Donatucci, Craig F

    2008-01-01

    Positive cultures, visible biofilm and confocal micrography confirm bacterial presence on clinically uninfected inflatable penile prostheses at revision surgery. Salvage irrigation has been proved to rescue patients with clinically infected inflatable penile prostheses. Similar washout at revision for noninfectious reasons significantly lowers subsequent infection rates. We investigated a larger series of patients for positive culture rates and evaluated implant capsule tissue culture rates before and after revision washout. At 4 institutions a total of 148 patients with inflatable penile prostheses underwent revision surgery for noninfectious reasons between June 2001 and September 2005. Swab cultures of the fluid around the pump and visible biofilm were obtained. Also, in 65 patients a wedge of tissue from the capsule that forms around the pump was cultured. After implant removal revision washout of the implant spaces was performed and a second wedge of tissue was cultured. Of the 148 patients 97 (66%) had positive bacterial swab cultures of the fluid around the pump or biofilm. A total of 124 isolates were cultured. Of the 65 implant capsule tissue cultures obtained before washout 28 (43%) were positive for bacteria, while 16 (25%) obtained after revision washout were positive. Positive cultures and visible bacterial biofilm are present on clinically uninfected inflatable penile prostheses at revision surgery in most patients. Revision washout appears to decrease the bacterial load on implant capsule tissue at revision surgery of inflatable penile prostheses for noninfectious reasons.

  5. Efficacy of Ozurdex implant in treatment of noninfectious intermediate uveitis

    Directory of Open Access Journals (Sweden)

    Swetha Palla

    2015-01-01

    Full Text Available Aims: To report our experiences using Ozurdex, a biodegradable implant, containing 0.7 mg of dexamethasone in the treatment of noninfectious intermediate uveitis. Settings and Design: Retrospective study design. Methods: We conducted a retrospective study of medical records of patients with noninfectious intermediate uveitis having either cystoid macular edema (CME or vitritis who were not responsive to standard treatment and subsequently received Ozurdex implant from March 2011 to April 2013. The outcomes measured were best-corrected visual acuity, central retinal thickness (CRT, and vitreous haze score. Statistical Analysis Used: Paired t-test was used to test the significance of difference between quantitative variables. A P < 0.05 is taken to denote significant relationship. Results: Twenty eyes of 15 patients with mean age of 39.8 years who received Ozurdex implant were included in the study. The mean baseline visual acuity improved from 0. 666 logarithm of the minimum angle of resolution (logMAR units to 0.479 logMAR units at 6 weeks after the implant. The mean CRT improved from 536.1 to 361.4 microns at 6 weeks postimplant both parameters were statistically significant. The ocular inflammation was controlled in almost all the patients. Cataract and raised intraocular pressure were documented complications. Conclusion: Ozurdex implant is a promising treatment option and efficient in controlling the inflammation and CME in cases of noninfectious intermediate uveitis not responding to standard treatment.

  6. Clinical evaluation of the stability of implants placed at different supracrestal levels.

    Science.gov (United States)

    Gultekin, B Alper; Sirali, Ali; Gultekin, Pinar; Ersanli, Selim

    2016-01-01

    The aim of this study was to evaluate the stability during healing and before loading of implants placed at two different supracrestal levels according to their collar texture. This retrospective study included patients who received posterior implants with the same macro design. Implants with a machined collar were placed 0.3 mm above the crestal bone (M group), while those with a laser-microtextured collar were placed 1 mm above the crestal bone (L group). All implants healed in a single stage with healing abutments. Implant stability quotient (ISQ) values were determined using resonance frequency analysis immediately after implant placement during surgery and after 1, 4, 8, and 12 weeks after surgery. Other evaluated factors for stability included the implant diameter and length and the site of placement (maxilla or mandible). In total, 103 implants (47 L, 56 M) were evaluated. The median ISQ values at baseline and 1 week after placement were significantly higher for the M group than for the L group (p=0.006 and p=0.031, respectively). There were no differences at the subsequent observation points. The ISQ value was higher for wide-diameter than regular diameter (p=0.001) and mandibular implants than maxillary implants (p=0.001 at 0-8. weeks; p=0.012 at 12 weeks) at all observation points. When diameter data were neglected, the implant length did not influence the ISQ value at all observation points. Our results suggest that submerging implant more inside bone may only influence primary stability. Moreover, the implant diameter and site of placement influence primary and secondary stability before loading, whereas the implant length does not when its diameter is not accounted for.

  7. Immediate breast reconstruction with anatomical implants following mastectomy: The radiation perspective

    Energy Technology Data Exchange (ETDEWEB)

    Ben-David, Merav, E-mail: Merav.ben-david@sheba.health.gov.il [Radiation Oncology Unit, Chaim Sheba Medical Center, Ramat Gan (Israel); Sackler School of Medicine, Tel Aviv University, Tel Aviv (Israel); Granot, Hila [Radiation Oncology Unit, Chaim Sheba Medical Center, Ramat Gan (Israel); Gelernter, Ilana [Statistical Laboratory, School of Mathematics, Tel Aviv University, Tel Aviv (Israel); Scheflan, Michael [Department of Surgery, Assuta and Herzliya Medical Centers, Ramat Gan (Israel)

    2016-07-01

    Immediate implant-based breast reconstruction followed by postmastectomy radiation therapy (PMRT) is controversial because of the risk of compromised treatment plans and concerns regarding cosmetic outcomes. We evaluated the effects of immediate direct-to-implant breast reconstruction with anatomical implants on the quality of PMRT delivered by 3-dimensional conformal radiotherapy (3D-CRT). In this retrospective, single-institution study, patients who had undergone reconstruction with direct anatomic implant, performed by a single surgeon, received 3D-CRT between 2008 and 2013. For each patient, 2 plans (including or excluding internal mammary nodes [IMN]) were created and calculated. The primary end point was the dose distribution among reconstructed breasts, heart, lungs, and IMNs, and between right and left breasts. Of 29 consecutive patients, 11 received right-sided and 18 received left-sided PMRT to a total dose of 50 Gy. For plans excluding IMN coverage, mean D{sub mean} for right and left reconstructed breasts was 49.09 Gy (98.2% of the prescribed dose) and 48.51 Gy (97.0%), respectively. For plans including IMNs, mean D{sub mean} was 49.15 Gy (98.3%) for right and 48.46 Gy (96.9%) for left reconstructed breasts; the mean IMN D{sub mean} was 47.27 Gy (right) and 47.89 Gy (left). Heart D{sub mean} was below 1.56 Gy for all plans. Mean total lung volume receiving a dose of ≥ 20 Gy was 13.80% to 19.47%. PMRT can be delivered effectively and safely by 3D-CRT after direct-to-implant breast reconstruction with anatomical implants, even if patients require IMN treatment.

  8. Early implant-associated osteomyelitis results in a peri-implanted bacterial reservoir

    DEFF Research Database (Denmark)

    Jensen, Louise Kruse; Koch, Janne; Aalbæk, Bent

    2017-01-01

    weight of Staphylococcus aureus or saline was inserted into the right tibial bone of 12 pigs. The animals were consecutively killed on day 2, 4 and 6 following implantation. Bone tissue around the implant was histologically evaluated. Identification of S. aureus was performed immunohistochemically...... on tissue section and with scanning electron microscopy and peptide nucleic acid in situ hybridization on implants. The distance of the peri-implanted pathological bone area (PIBA), measured perpendicular to the implant, was significantly larger in infected animals compared to controls (p = 0...

  9. Evaluation of stress distribution characteristics on various bar designs of three-implant-supported mandibular overdentures

    Directory of Open Access Journals (Sweden)

    Emre Tokar

    2017-01-01

    Full Text Available Objective: Implant-supported-overdentures, instead of conventional complete dentures, are frequently recommended to rehabilitate patients having edentulous mandible. The aim of this study was to evaluate the stress distribution characteristics of mandibular implant-supported overdentures with four different bar attachment designs. Materials and Method: A photoelastic mandibular model with three implants (3.75 mm - 13 mm placed at the interforaminal region was generated from a cast of an edentulous mandible. Four mandibular bar overdenture designs were fabricated: bar-clip, bar-galvano, bar-locator, and bar-ceka. Axial vertical loads (135 N were applied to the central fossa of the right first molar area for each overdenture design. Stress concentrations were recorded photographically and analyzed visually. Results: The tested bar attachment designs revealed low and moderate stress levels. The lowest stress was observed with the bar-clip design, followed by bar-locator, bar-ceka, and bar-galvano designs. Conclusion: The loads were distributed to all of the implants. Studied designs experienced moderate stress levels around the loaded side implant. Bars with distally placed stud attachments and surface treatment with electroforming seems to increase stress levels around the implants.

  10. Immediate implant placement and provisionalization with simultaneous guided bone regeneration in the esthetic zone

    Directory of Open Access Journals (Sweden)

    Chih-Long Chen

    2011-03-01

    Full Text Available The procedure for immediate implant placement and provisionalization is time-saving, possibly with only one surgical intervention required, although allowing maximal preservation of peri-implant tissues. In this case, we extracted a fractured maxillary right central incisor of a 46-year-old woman with high esthetic expectations, and a transmucosal implant was immediately installed. Simultaneous guided bone regeneration was performed to correct the defects at the facial side of the socket and augment the alveolar ridge horizontally. Primary stability of the implant body and wound closure without tension were confirmed. Connection of a 15° angled abutment and fabrication of a provisional acrylic resin crown without occlusal contact were also completed in the same appointment. After intensive follow-up and soft-tissue molding for 6 months, the customized zirconia abutment and all-ceramic crown were definitively fabricated. During the 18-month follow-up period, the patient was satisfied with the esthetic and functional results.

  11. Influence of different implant materials on the primary stability of orthodontic mini-implants

    OpenAIRE

    Chin-Yun Pan; Szu-Ting Chou; Yu-Chuan Tseng; Yi-Hsin Yang; Chao-Yi Wu; Ting-Hsun Lan; Pao-Hsin Liu; Hong-Po Chang

    2012-01-01

    This study evaluates the influence of different implant materials on the primary stability of orthodontic mini-implants by measuring the resonance frequency. Twenty-five orthodontic mini-implants with a diameter of 2 mm were used. The first group contained stainless steel mini-implants with two different lengths (10 and 12 mm). The second group included titanium alloy mini-implants with two different lengths (10 and 12 mm) and stainless steel mini-implants 10 mm in length. The mini-implants w...

  12. Complex diagnosis in dental implantation and potentialities of predicting the results of treatment

    International Nuclear Information System (INIS)

    Matveeva, A.I.; Kulakov, A.A.

    1995-01-01

    Experience gained by the implantation Department of Central Research Institute of Dentistry in many years showed that comprehensive clinical and laboratory examinations, including roentgenological examination, functional diagnosis and examination of the immunity system help detect all unfavorable local and general factors. In patients referred to the risk group implantation is possible after preoperative treatment. Designing of STOM-1 and STOM-2, as well as of UMR-1 software helped carry our the calculations using IBM PC and determine the optimal type of the graft, place of its introduction, and number of grafts, as well as calculate the optimal design of the prosthesis

  13. Implant-abutment gap versus microbial colonization : Clinical significance based on a literature review

    NARCIS (Netherlands)

    Passos, Sheila Pestana; May, Liliana Gressler; Faria, Renata; Ozcan, Mutlu; Bottino, Marco Antonio

    2013-01-01

    Microorganisms from the oral cavity may settle at the implant-abutment interface (IAI). As a result, tissue inflammation could occur around these structures. The databases MEDLINE/PubMed and PubMed Central were used to identify articles published from 1981 through 2012 related to the microbial

  14. No influence of simultaneous bone-substitute application on the success of immediately loaded dental implants: a retrospective cohort study.

    Science.gov (United States)

    Kopp, Sigmar; Behrend, Detlef; Kundt, Günther; Ottl, Peter; Frerich, Bernhard; Warkentin, Mareike

    2013-06-01

    To examine the influence of bone-substitute application during implantation on the success of immediately placed and loaded dental implants. A total of 147 consecutive patients (age, 16.5-80.4 years) were provided with 696 immediately loaded implants. The mean follow-up time was 34.1 months. Of these implants, 50.4% (n=351) were immediately placed into extraction sockets. A total of 119 implants were added by simultaneous bone-substitute application (NanoBone, Artoss GmbH, Rostock Germany), whereas the other implants were placed in healed bone. Univariate and multivariate analysis was performed using IBM SPSS V.20. The overall implant success rate was 96.1%. Implants with simultaneous bone replacement had a hazard ratio of 0.877 (p=0.837); 95% CI, 0.253-3.04). Factors found to be statistically significant modifiers of success on multivariate analysis (p<0.05) included type of superstructure (p<0.001), implant-abutment connection (p<0.001), membrane use (p=0.010), and jaw (p=0.026). None of the other factors investigated were significant modifiers. The present study demonstrates high success rates for immediately loaded implants and their superstructures independent of the simultaneous application of bone substitute. The declared aim of socket preservation, the prevention avoiding bone loss, is achieved in the immediate implant placement scenario under immediate-loading conditions.

  15. Influence of peri-implant artifacts on bone morphometric analysis with micro-computed tomography.

    Science.gov (United States)

    Song, Jin Wook; Cha, Jung Yul; Bechtold, Till Edward; Park, Young Chel

    2013-01-01

    To determine the optimal dilation pixel size distance from the mini-implant interface needed to compensate for the metal artifact on micro-computed tomography (micro-CT) for bone morphometric analysis. A total of 72 self-drilling mini-implants were placed into the buccal alveolar bone of six male beagle dogs. After 12 weeks of orthodontic loading, specimens were harvested and scanned with micro-CT (Skyscan 1076) at a resolution of 9 μm. Using the reload plug-in and dilation procedure of CTAn, the percentage of bone-implant contact (BIC) and bone volume density (BV/TV, bone volume/total volume), respectively, were measured from one to seven pixels from the metal implant surface. Each pixel size of dilation (PSD) were compared with that of a ground histologic section, and the optimal PSD for bone morphometric analysis using micro-CT was determined. BIC values from micro-CT analysis decreased when the PSD increased (P micro-CT showed the highest correlation coefficient with BIC from histologic slides when the PSD was 5 to 7 (P micro-CT showed a very high correlation with BV/TV from histologic slides in all ranges (P micro-CT, at least 5 PSD from the metal implant surface is needed.

  16. Spectral Analysis Related to Bare-Metal and Drug-Eluting Coronary Stent Implantation

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Rose Mary Ferreira Lisboa da, E-mail: roselisboa@cardiol.br [Faculdade de Medicina da UFMG, Divinópolis, MG (Brazil); Silva, Carlos Augusto Bueno [Faculdade de Medicina da UFMG, Divinópolis, MG (Brazil); Belo Horizonte, Hospital São João de Deus, Divinópolis, MG (Brazil); Greco, Otaviano José [Belo Horizonte, Hospital São João de Deus, Divinópolis, MG (Brazil); Moreira, Maria da Consolação Vieira [Faculdade de Medicina da UFMG, Divinópolis, MG (Brazil)

    2014-08-15

    The autonomic nervous system plays a central role in cardiovascular regulation; sympathetic activation occurs during myocardial ischemia. To assess the spectral analysis of heart rate variability during stent implantation, comparing the types of stent. This study assessed 61 patients (mean age, 64.0 years; 35 men) with ischemic heart disease and indication for stenting. Stent implantation was performed under Holter monitoring to record the spectral analysis of heart rate variability (Fourier transform), measuring the low-frequency (LF) and high-frequency (HF) components, and the LF/HF ratio before and during the procedure. Bare-metal stent was implanted in 34 patients, while the others received drug-eluting stents. The right coronary artery was approached in 21 patients, the left anterior descending, in 28, and the circumflex, in 9. As compared with the pre-stenting period, all patients showed an increase in LF and HF during stent implantation (658 versus 185 ms2, p = 0.00; 322 versus 121, p = 0.00, respectively), with no change in LF/HF. During stent implantation, LF was 864 ms2 in patients with bare-metal stents, and 398 ms2 in those with drug-eluting stents (p = 0.00). The spectral analysis of heart rate variability showed no association with diabetes mellitus, family history, clinical presentation, beta-blockers, age, and vessel or its segment. Stent implantation resulted in concomitant sympathetic and vagal activations. Diabetes mellitus, use of beta-blockers, and the vessel approached showed no influence on the spectral analysis of heart rate variability. Sympathetic activation was lower during the implantation of drug-eluting stents.

  17. Facial and occlusal esthetic improvements of an adult skeletal Class III malocclusion using surgical, orthodontic, and implant treatment

    Science.gov (United States)

    de Almeida Cardoso, Mauricio; de Avila, Erica Dorigatti; Guedes, Fabio Pinto; Battilani Filho, Valter Antonio Ban; Capelozza Filho, Leopoldino; Correa, Marcio Aurelio; Nary Filho, Hugo

    2016-01-01

    The aim of this clinical report is to describe the complex treatment of an adult Class III malocclusion patient who was disappointed with the outcome of a previous oral rehabilitation. Interdisciplinary treatment planning was performed with a primary indication for implant removal because of marginal bone loss and gingival recession, followed by orthodontic and surgical procedures to correct the esthetics and skeletal malocclusion. The comprehensive treatment approach included: (1) implant removal in the area of the central incisors; (2) combined orthodontic decompensation with mesial displacement and forced extrusion of the lateral incisors; (3) extraction of the lateral incisors and placement of new implants corresponding to the central incisors, which received provisional crowns; (4) orthognathic surgery for maxillary advancement to improve occlusal and facial relationships; and finally, (5) orthodontic refinement followed by definitive prosthetic rehabilitation of the maxillary central incisors and reshaping of the adjacent teeth. At the three-year follow-up, clinical and radiographic examinations showed successful replacement of the central incisors and improved skeletal and esthetic appearances. Moreover, a Class II molar relationship was obtained with an ideal overbite, overjet, and intercuspation. In conclusion, we report the successful esthetic anterior rehabilitation of a complex case in which interdisciplinary treatment planning improved facial harmony, provided gingival architecture with sufficient width and thickness, and improved smile esthetics, resulting in enhanced patient comfort and satisfaction. This clinical case report might be useful to improve facial esthetics and occlusion in patients with dentoalveolar and skeletal defects. PMID:26877982

  18. Surgical pitfalls with custom-made porous hydroxyapatite cranial implants

    Directory of Open Access Journals (Sweden)

    Bruno Zanotti

    2015-03-01

    Full Text Available Aim: Cranioplasty implants are used primarily in cases of surgical cranial decompression following pathological elevations of intracranial pressure. Available bone substitutes include porous hydroxyapatite (HA and polymethylmethacrylate. Whichever material is used, however, prosthetic cranial implants are susceptible to intra- and postsurgical complications and even failure. The aim of this study was to investigate such occurrences in HA cranioplasty implants, seeking not only to determine the likely causes (whether correlated or not with the device itself but also, where possible, to suggest countermeasures. Methods: We analyzed information regarding failures or complications reported in postmarketing surveillance and clinical studies of patients treated worldwide with custom-made HA cranial implants (Custom Bone Service Fin-Ceramica Faenza, Italy in the period 1997-2013. Results: The two most common complications were implant fractures (84 cases, 2.9% of the total fitted and infections (51 cases, 1.77%. Conclusion: Although cranioplasties are superficial and not difficult types of surgery, and use of custom-made implants are often considered the "easy" option from a surgical perspective, these procedures are nonetheless plagued by potential pitfalls. If performed well they yield more than satisfactory results from the points of view of both the patient and surgeon, but lack of appropriate care can open the door to numerous potential sources of failure, which can compromise-even irreparably-the ability to heal.

  19. Stability of tapered and parallel-walled dental implants: A systematic review and meta-analysis.

    Science.gov (United States)

    Atieh, Momen A; Alsabeeha, Nabeel; Duncan, Warwick J

    2018-05-15

    Clinical trials have suggested that dental implants with a tapered configuration have improved stability at placement, allowing immediate placement and/or loading. The aim of this systematic review and meta-analysis was to evaluate the implant stability of tapered dental implants compared to standard parallel-walled dental implants. Applying the guidelines of Preferred Reporting Items for Systematic Reviews and Meta-analyses (PRISMA) statement, randomized controlled trials (RCTs) were searched for in electronic databases and complemented by hand searching. The risk of bias was assessed using the Cochrane Collaboration's Risk of Bias tool and data were analyzed using statistical software. A total of 1199 studies were identified, of which, five trials were included with 336 dental implants in 303 participants. Overall meta-analysis showed that tapered dental implants had higher implant stability values than parallel-walled dental implants at insertion and 8 weeks but the difference was not statistically significant. Tapered dental implants had significantly less marginal bone loss compared to parallel-walled dental implants. No significant differences in implant failure rate were found between tapered and parallel-walled dental implants. There is limited evidence to demonstrate the effectiveness of tapered dental implants in achieving greater implant stability compared to parallel-walled dental implants. Superior short-term results in maintaining peri-implant marginal bone with tapered dental implants are possible. Further properly designed RCTs are required to endorse the supposed advantages of tapered dental implants in immediate loading protocol and other complex clinical scenarios. © 2018 Wiley Periodicals, Inc.

  20. High Re-Operation Rates Using Conserve Metal-On-Metal Total Hip Articulations

    DEFF Research Database (Denmark)

    Mogensen, S L; Jakobsen, Thomas; Christoffersen, Hardy

    2016-01-01

    INTRODUCTION: Metal-on-metal hip articulations have been intensely debated after reports of adverse reactions and high failure rates. The aim of this study was to retrospectively evaluate the implant of a metal-on.metal total hip articulation (MOM THA) from a single manufacture in a two-center st......INTRODUCTION: Metal-on-metal hip articulations have been intensely debated after reports of adverse reactions and high failure rates. The aim of this study was to retrospectively evaluate the implant of a metal-on.metal total hip articulation (MOM THA) from a single manufacture in a two...

  1. Influence of different implant materials on the primary stability of orthodontic mini-implants.

    Science.gov (United States)

    Pan, Chin-Yun; Chou, Szu-Ting; Tseng, Yu-Chuan; Yang, Yi-Hsin; Wu, Chao-Yi; Lan, Ting-Hsun; Liu, Pao-Hsin; Chang, Hong-Po

    2012-12-01

    This study evaluates the influence of different implant materials on the primary stability of orthodontic mini-implants by measuring the resonance frequency. Twenty-five orthodontic mini-implants with a diameter of 2 mm were used. The first group contained stainless steel mini-implants with two different lengths (10 and 12 mm). The second group included titanium alloy mini-implants with two different lengths (10 and 12 mm) and stainless steel mini-implants 10 mm in length. The mini-implants were inserted into artificial bones with a 2-mm-thick cortical layer and 40 or 20 lb/ft(3) trabecular bone density at insertion depths of 2, 4, and 6 mm. The resonance frequency of the mini-implants in the artificial bone was detected with the Implomates(®) device. Data were analyzed by two-way analysis of variance followed by the Tukey honestly significant difference test (α = 0.05). Greater insertion depth resulted in higher resonance frequency, whereas longer mini-implants showed lower resonance frequency values. However, resonance frequency was not influenced by the implant materials titanium alloy or stainless steel. Therefore, the primary stability of a mini-implant is influenced by insertion depth and not by implant material. Insertion depth is extremely important for primary implant stability and is critical for treatment success. Copyright © 2012. Published by Elsevier B.V.

  2. Influence of different implant materials on the primary stability of orthodontic mini-implants

    Directory of Open Access Journals (Sweden)

    Chin-Yun Pan

    2012-12-01

    Full Text Available This study evaluates the influence of different implant materials on the primary stability of orthodontic mini-implants by measuring the resonance frequency. Twenty-five orthodontic mini-implants with a diameter of 2 mm were used. The first group contained stainless steel mini-implants with two different lengths (10 and 12 mm. The second group included titanium alloy mini-implants with two different lengths (10 and 12 mm and stainless steel mini-implants 10 mm in length. The mini-implants were inserted into artificial bones with a 2-mm-thick cortical layer and 40 or 20 lb/ft3 trabecular bone density at insertion depths of 2, 4, and 6 mm. The resonance frequency of the mini-implants in the artificial bone was detected with the Implomates® device. Data were analyzed by two-way analysis of variance followed by the Tukey honestly significant difference test (α = 0.05. Greater insertion depth resulted in higher resonance frequency, whereas longer mini-implants showed lower resonance frequency values. However, resonance frequency was not influenced by the implant materials titanium alloy or stainless steel. Therefore, the primary stability of a mini-implant is influenced by insertion depth and not by implant material. Insertion depth is extremely important for primary implant stability and is critical for treatment success.

  3. Power harvesting using PZT ceramics embedded in orthopedic implants.

    Science.gov (United States)

    Chen, Hong; Liu, Ming; Jia, Chen; Wang, Zihua

    2009-09-01

    Battery lifetime has been the stumbling block for many power-critical or maintenance-free real-time embedded applications, such as wireless sensors and orthopedic implants. Thus a piezoelectric material that could convert human motion into electrical energy provides a very attractive solution for clinical implants. In this work, we analyze the power generation characteristics of stiff lead zirconate titanate (PZT) ceramics and the equivalent circuit through extensive experiments. Our experimental framework allows us to explore many important design considerations of such a PZT-based power generator. Overall we can achieve a PZT element volume of 0.5 x 0.5 x 1.8 cm, which is considerably smaller than the results reported so far. Finally, we outline the application of our PZT elements in a total knee replacement (TKR) implant.

  4. Comparison of 3D displacements of screw-retained zirconia implant crowns into implants with different internal connections with respect to screw tightening.

    Science.gov (United States)

    Rebeeah, Hanadi A; Yilmaz, Burak; Seidt, Jeremy D; McGlumphy, Edwin; Clelland, Nancy; Brantley, William

    2018-01-01

    Internal conical implant-abutment connections without horizontal platforms may lead to crown displacement during screw tightening and torque application. This displacement may affect the proximal contacts and occlusion of the definitive prosthesis. The purpose of this in vitro study was to evaluate the displacement of custom screw-retained zirconia single crowns into a recently introduced internal conical seal implant-abutment connection in 3D during hand and torque driver screw tightening. Stereolithic acrylic resin models were printed using computed tomography data from a patient missing the maxillary right central incisor. Two different internal connection implant systems (both ∼11.5 mm) were placed in the edentulous site in each model using a surgical guide. Five screw-retained single zirconia computer-aided design and computer-aided manufacturing (CAD-CAM) crowns were fabricated for each system. A pair of high-resolution digital cameras was used to record the relationship of the crown to the model. The crowns were tightened according to the manufacturers' specifications using a torque driver, and the cameras recorded their relative position again. Three-dimensional image correlation was used to measure and compare crown positions, first hand tightened and then torque driven. The displacement test was repeated 3 times for each crown. Commercial image correlation software was used to extract the data and compare the amount of displacement vertically, mesiodistally, and buccolingually. Repeated-measures ANOVA calculated the relative displacements for all 5 specimens for each implant for both crown screw hand tightening and after applied torque. A Student t test with Bonferroni correction was used for pairwise comparison of interest to determine statistical differences between the 2 implants (α=.05). The mean vertical displacements were statistically higher than the mean displacements in the mesiodistal and buccolingual directions for both implants

  5. Imaging of common breast implants and implant-related complications: A pictorial essay

    OpenAIRE

    Shah, Amisha T; Jankharia, Bijal B

    2016-01-01

    The number of women undergoing breast implant procedures is increasing exponentially. It is, therefore, imperative for a radiologist to be familiar with the normal and abnormal imaging appearances of common breast implants. Diagnostic imaging studies such as mammography, ultrasonography, and magnetic resonance imaging are used to evaluate implant integrity, detect abnormalities of the implant and its surrounding capsule, and detect breast conditions unrelated to implants. Magnetic resonance i...

  6. Impact of implant size on cement filling in hip resurfacing arthroplasty.

    Science.gov (United States)

    de Haan, Roel; Buls, Nico; Scheerlinck, Thierry

    2014-01-01

    Larger proportions of cement within femoral resurfacing implants might result in thermal bone necrosis. We postulate that smaller components are filled with proportionally more cement, causing an elevated failure rate. A total of 19 femoral heads were fitted with polymeric replicas of ReCap (Biomet) resurfacing components fixed with low-viscosity cement. Two specimens were used for each even size between 40 and 56 mm and one for size 58 mm. All specimens were imaged with computed tomography, and the cement thickness and bone density were analyzed. The average cement mantle thickness was 2.63 mm and was not correlated with the implant size. However, specimen with low bone density had thicker cement mantles regardless of size. The average filling index was 36.65% and was correlated to both implant size and bone density. Smaller implants and specimens with lower bone density contained proportionally more cement than larger implants. According to a linear regression model, bone density but not implant size influenced cement thickness. However, both implant size and bone density had a significant impact on the filling index. Large proportions of cement within the resurfacing head have the potential to generate thermal bone necrosis and implant failure. When considering hip resurfacing in patients with a small femoral head and/or osteoporotic bone, extra care should be taken to avoid thermal bone necrosis, and alternative cementing techniques or even cementless implants should be considered. This study should help delimiting the indications for hip resurfacing and to choose an optimal cementing technique taking implant size into account.

  7. Dental Implant Surgery

    Science.gov (United States)

    ... here to find out more. Dental Implant Surgery Dental Implant Surgery Dental implant surgery is, of course, ... to find out more. Wisdom Teeth Management Wisdom Teeth Management An impacted wisdom tooth can damage neighboring ...

  8. [Clinical application of individualized three-dimensional printing implant template in multi-tooth dental implantation].

    Science.gov (United States)

    Wang, Lie; Chen, Zhi-Yuan; Liu, Rong; Zeng, Hao

    2017-08-01

    To study the value and satisfaction of three-dimensional printing implant template and conventional implant template in multi-tooth dental implantation. Thirty cases (83 teeth) with missing teeth needing to be implanted were randomly divided into conventional implant template group (CIT group, 15 cases, 42 teeth) and 3D printing implant template group (TDPIT group, 15 cases, 41 teeth). Patients in CIT group were operated by using conventional implant template, while patients in TDPIT group were operated by using three-dimensional printing implant template. The differences of implant neck and tip deviation, implant angle deviation and angle satisfaction between the two groups were compared. The difference of probing depth and bone resorption of implant were compared 1 year after operation between the two groups. The difference of success rate and satisfaction of dental implantation were compared 1 year after operation between the two groups. SPSS19.0 software package was used for statistical analysis. The deviation direction of the neck and the tip in disto-mesial, bucco-palatal, vertical direction and angle of implants in disto-mesial and bucco-palatal direction in TDPIT group were significantly lower than in CIT group (P0.05). The difference of the cumulative success rate in dental implantation at 3 months and 6 months between the two groups were not significant (P>0.05), but the cumulative success rate of TDPIT group was significantly higher than CIT group at 9 months and 1 year (90.48% vs 100%,P=0.043). The patients' satisfaction rate of dental implantation in TDPIT group was significantly higher than in CIT group (86.67% vs 53.33%, P=0.046). Using three-dimensional printing implant template can obtain better accuracy of implant, higher implant success rate and better patients' satisfaction than using conventional implant template. It is suitable for clinical application.

  9. Summary of the clinical use of the Symbion total artificial heart: a registry report.

    Science.gov (United States)

    Johnson, K E; Prieto, M; Joyce, L D; Pritzker, M; Emery, R W

    1992-01-01

    Several models of total artificial hearts have been used for transient or permanent circulatory support in patients with decompensation. The most successful and widely used device, however, has been the Symbion total artificial heart. From Dec. 12, 1982, to Jan. 1, 1991, 180 Symbion total artificial hearts were implanted in 176 patients in 28 centers. Five patients received a Symbion total artificial heart as a permanent circulatory support device, whereas 171 patients received the device as a bridge to heart transplantation. Of the 175 bridge devices (171 patients) 141 were Symbion J7-70 hearts and 34 were Symbion J7-100 hearts. Four patients received two total artificial hearts, the second one after the failure of a transplanted heart because of either rejection (two patients) or donor heart failure (2 patients). Most of the recipients were males (152). The age was 42 +/- 12 years (mean +/- SD) with a weight of 74 +/- 14 kg. The most common indications for implantation included deterioration while awaiting heart transplant (36%) and acute cardiogenic shock (32%). The cause of heart disease was primarily ischemic (52%) and idiopathic (35%) cardiomyopathy. Duration of implantation ranged from 0 to 603 days (mean 25 +/- 64 days). One hundred three (60%) patients had the device less than 2 weeks, 37 (22%) between 2 to 4 weeks and 31 (18%) more than 4 weeks. Complications during implantation included infection (37%), thromboembolic events (stroke 7%, transient ischemic attack 4%), kidney failure requiring dialysis (20%), bleeding requiring intervention (26%), and device malfunction (4%). Of the 171 patients, 118 (69%) underwent orthotopic heart transplantation. Actuarial survival for all patients with implants was 62% for 30 days and 42% for 1 year, and for patients with transplants was 72% for 30 days and 57% for 1 year. The main causes of death were sepsis (33%), multiorgan failure (21%), and posttransplant rejection (10%). The results indicate a relative success of

  10. Hemiepiphysiodesis Implants for Late-onset Tibia Vara: A Comparison of Cost, Surgical Success, and Implant Failure.

    Science.gov (United States)

    Funk, Shawn S; Mignemi, Megan E; Schoenecker, Jonathan G; Lovejoy, Steven A; Mencio, Gregory A; Martus, Jeffrey E

    2016-01-01

    The purpose of this study was to compare hemiepiphysiodesis implants for late-onset tibia vara and to evaluate patient characteristics that may predict surgical failure. This is a retrospective review of late-onset tibia vara patients treated with temporary hemiepiphysiodesis from 1998 to 2012. Mechanical axis deviation (MAD), mechanical axis angle, mechanical lateral distal femoral angle, and medial proximal tibial angle were measured on standing bone length radiographs. Surgical failure was defined as residual deformity requiring osteotomy, revision surgery, or MAD exceeding 40 mm at the time of final follow-up. Implant failure was recorded. Costs included implants and disposables required for construct placement. Staple constructs included 2 or 3 staples. Plate constructs included the plate, screws, guide wires, and drill bits. A total of 25 patients with 38 temporary lateral proximal tibia hemiepiphysiodeses met the inclusion criteria. The average body mass index (BMI) was 39.1 kg/m with an average follow-up of 3.0 years (minimum 1 y). Surgical failure occurred in 57.9% of patients. Greater BMI (P=0.05) and more severe deformity (MAD, mechanical axis angle, and medial proximal tibial angle; Pfailure. Younger age predicted higher rates of implant failure (Pfailure between staple and plate systems. Hospital costs of plate constructs ($781 to $1244) were 1.5 to 3.5 times greater than the staple constructs ($332 to $498). Greater BMI, more severe deformity, and younger age were predictive of surgical or implant failure. There was no difference in success between implant types, whereas the cost of plate constructs was 1.5 to 3.5 times greater than staples. The rate of surgical failure was high (58%) and consideration should be given to reserving hemiepiphysiodesis for patients with lower BMI and less severe deformity. In our population, if hemiepiphysiodesis was not offered to patients with BMI>35 or MAD>80 mm varus, the surgical failure rate would diminish to 28

  11. Productivity of lexical categories in French-speaking children with cochlear implants.

    Science.gov (United States)

    Le Normand, M-T; Ouellet, C; Cohen, H

    2003-11-01

    The productivity of lexical categories was studied longitudinally in a sample of 17 young hearing-impaired French-speaking children with cochlear implants. Age of implantation ranged from 22 months to 76 months. Spontaneous speech samples were collected at six-month intervals over a period of 36 months, starting at the one-word stage. Four general measures of their linguistic production (number of utterances, verbal fluency, vocabulary, and grammatical production) as well as 36 specific lexical categories, according to the CHILDES codes, were computed in terms of tokens, i.e., total number of words. Cochlear-implanted children (CI) were compared to a French database of normally hearing children aged 2-4 compiled by the first author. Follow-up results indicate that, at the two-year post-implantation follow-up, noun, and verb morphology was significantly impaired. At the three-year follow-up, the cochlear-implanted group had recovered on adjectives, determiners and nouns, main verbs, and auxiliaries. The two groups differed significantly in processing locative adverbs, prepositions, pronouns, and verbs (infinitive verb, modal, and modal lexical), but individual variability within the cochlear-implanted group was substantial. Results are discussed in terms of recovery and developmental trends and variability in the acquisition of lexical categories by French children two years and three years post-implantation.

  12. No clinical benefit of titanium nitride coating in cementless mobile-bearing total knee arthroplasty

    NARCIS (Netherlands)

    van Hove, R.P.; Brohet, R.M.; van Royen, B.J.; Nolte, P.A.

    2015-01-01

    Purpose: Titanium nitride (TiN) coating of cobalt–chromium–molybdenum (CoCrMo) implants has shown to improve the biomechanical properties of the implant surface and to reduce adhesive wear in vitro. It is yet unknown whether TiN coating of total knee prosthesis (TKP) affects the postoperative

  13. Immediate occlusal loading of NanoTite™ tapered implants: a prospective 1-year clinical and radiographic study.

    Science.gov (United States)

    Östman, Pär-Olov; Wennerberg, Ann; Ekestubbe, Annika; Albrektsson, Tomas

    2013-12-01

    During the last decade, high success rates have been reported for implants placed with immediate loading procedures, especially when bone quality and quantity provide good implant stability. In many of these studies, straight-walled implants with moderately rough surfaces were employed. Tapered implants are becoming increasingly more popular due to standardized drilling protocols and reports of high initial primary stability. The aim of the present prospective, single center clinical study was to evaluate surface topographical analysis and the clinical and radiographic outcomes of the NanoTite™ (BIOMET 3i, Palm Beach Gardens, FL, USA) Tapered Implant when used for immediate loading of fixed prostheses and single-tooth restorations. Forty-two patients who needed implant treatment and met admission criteria agreed to participate in the study and were consecutively enrolled. Surgical implant placement requirements consisted of a final torque of a least 30 Ncm prior to final seating and an implant stability quotient above 55. A total of 139 NanoTite Tapered implants (112 maxillary and 27 mandibular) were placed by one investigator, and the majority of these implants (n = 77/55%) were placed in posterior regions, and in soft bone (n = 90/65%). A total of 57 prosthetic constructions were evaluated consisting of 20 single-tooth restorations, 30 fixed partial dentures, and 7 complete, fixed maxillary restorations. Radiographs were taken at baseline and at 12 months of follow-up. Of the 139 study implants, one implant failure was declared. The overall cumulative survival rate at 1 year is 99.4%. Mean marginal bone resorption is 1.01 mm (SD 0.85) during the first year of function. Although limited to the short follow-up, immediate loading of NanoTite Tapered implants seems to be a viable option in implant rehabilitation, when insertion torque of at least 30 Ncm is achieved. Further studies are needed to authenticate the finding of this study. © 2012 Wiley

  14. Automatic Model Generation Framework for Computational Simulation of Cochlear Implantation.

    Science.gov (United States)

    Mangado, Nerea; Ceresa, Mario; Duchateau, Nicolas; Kjer, Hans Martin; Vera, Sergio; Dejea Velardo, Hector; Mistrik, Pavel; Paulsen, Rasmus R; Fagertun, Jens; Noailly, Jérôme; Piella, Gemma; González Ballester, Miguel Ángel

    2016-08-01

    Recent developments in computational modeling of cochlear implantation are promising to study in silico the performance of the implant before surgery. However, creating a complete computational model of the patient's anatomy while including an external device geometry remains challenging. To address such a challenge, we propose an automatic framework for the generation of patient-specific meshes for finite element modeling of the implanted cochlea. First, a statistical shape model is constructed from high-resolution anatomical μCT images. Then, by fitting the statistical model to a patient's CT image, an accurate model of the patient-specific cochlea anatomy is obtained. An algorithm based on the parallel transport frame is employed to perform the virtual insertion of the cochlear implant. Our automatic framework also incorporates the surrounding bone and nerve fibers and assigns constitutive parameters to all components of the finite element model. This model can then be used to study in silico the effects of the electrical stimulation of the cochlear implant. Results are shown on a total of 25 models of patients. In all cases, a final mesh suitable for finite element simulations was obtained, in an average time of 94 s. The framework has proven to be fast and robust, and is promising for a detailed prognosis of the cochlear implantation surgery.

  15. Reduced Operating Time but Not Blood Loss With Cruciate Retaining Total Knee Arthroplasty

    Science.gov (United States)

    Vermesan, Dinu; Trocan, Ilie; Prejbeanu, Radu; Poenaru, Dan V; Haragus, Horia; Gratian, Damian; Marrelli, Massimo; Inchingolo, Francesco; Caprio, Monica; Cagiano, Raffaele; Tatullo, Marco

    2015-01-01

    Background There is no consensus regarding the use of retaining or replacing cruciate implants for patients with limited deformity who undergo a total knee replacement. Scope of this paper is to evaluate whether a cruciate sparing total knee replacement could have a reduced operating time compared to a posterior stabilized implant. Methods For this purpose, we performed a randomized study on 50 subjects. All procedures were performed by a single surgeon in the same conditions to minimize bias and only knees with a less than 20 varus deviation and/or maximum 15° fixed flexion contracture were included. Results Surgery time was significantly shorter with the cruciate retaining implant (P = 0.0037). The mean duration for the Vanguard implant was 68.9 (14.7) and for the NexGen II Legacy was 80.2 (11.3). A higher range of motion, but no significant Knee Society Scores at 6 months follow-up, was used as controls. Conclusions In conclusion, both implants had the potential to assure great outcomes. However, if a decision has to be made, choosing a cruciate retaining procedure could significantly reduce the surgical time. When performed under tourniquet, this gain does not lead to reduced blood loss. PMID:25584102

  16. Biomechanical comparison of reverse total shoulder arthroplasty systems in soft tissue-constrained shoulders.

    Science.gov (United States)

    Henninger, Heath B; King, Frank K; Tashjian, Robert Z; Burks, Robert T

    2014-05-01

    Numerous studies have examined the biomechanics of isolated variables in reverse total shoulder arthroplasty. This study directly compared the composite performance of two reverse total shoulder arthroplasty systems; each system was designed around either a medialized or a lateralized glenohumeral center of rotation. Seven pairs of shoulders were tested on a biomechanical simulator. Center of rotation, position of the humerus, passive and active range of motion, and force to abduct the arm were quantified. Native arms were tested, implanted with a Tornier Aequalis or DJO Surgical Reverse Shoulder Prosthesis (RSP), and then retested. Differences from the native state were then documented. Both systems shifted the center of rotation medially and inferiorly relative to native. Medial shifts were greater in the Aequalis implant (P .05). Both reverse total shoulder arthroplasty systems exhibited adduction deficits, but the RSP implant deficit was smaller (P = .046 between implants). Both systems reduced forces to abduct the arm compared with native, although the Aequalis required more force to initiate motion from the resting position (P = .022). Given the differences in system designs and configurations, outcome variables were generally comparable. The RSP implant allowed slightly more adduction, had a more lateralized humeral position, and required less force to initiate elevation. These factors may play roles in limiting scapular notching, improving active external rotation by normalizing the residual rotator cuff length, and limiting excessive stress on the deltoid. Copyright © 2014 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.

  17. Evaluation of fixation of expandable implants in the mandibles of ovariectomized sheep.

    Science.gov (United States)

    Xiao, Jian-Rui; Li, De-Hua; Chen, Yu-Xuan; Chen, Shu-Jun; Guan, Su-Min; Kong, Liang

    2013-04-01

    This study aimed to investigate the effects of an expandable implant (EI) in ovariectomized sheep. The EI and taper implant (control group) were produced and placed in mandibles of ovariectomized sheep. Twelve weeks after implantation, resonance frequency analysis, biomechanical tests, histomorphometry, and micro-computed tomography were applied to detect the osseointegration in the 2 groups. The implant stability quotient values, maximal pullout forces, and bone-implant contact (BIC) were 60.3 ± 7.9, 511.0 ± 18.7 N, and 53.14% ± 4.56%, respectively, in the EI group and 58.3 ± 8.9, 394.5 ± 54.5 N, and 46.85% ± 5.04%, respectively, in the control group. There was no significant difference between the 2 groups in implant stability quotient values (P > .05); however, in the EI group the maximal pullout force and BIC were increased significantly (P bone volume/total volume ratio and trabecular number increased significantly (P < .01) and trabecular separation decreased significantly (P < .05) in the EI group. EI could improve osseointegration in osteoporosis after 12 weeks of implantation by increasing BIC around the implant and by supplying an extra osseointegration surface. Copyright © 2013 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  18. Musical Methods for Little Digital Ears — Musical Learning with Preschool Cochlear Implant Users

    DEFF Research Database (Denmark)

    Petersen, Bjørn; Hardgrove Hansen, Roberta; Beyer, Karen

    2010-01-01

    was measured objectively at the beginning and end of the intervention period. For a musical performance reference, test data were collected from a group of normally hearing peers. Results: The children in the music group outperformed the controls in all tests. Their musical discrimination abilities improved......Prelingually deaf children who receive cochlear implants (CI) early can successfully develop age-appropriate language skills provided sufficient intervention measures are initiated. However, little is known about the music perception and enjoyment of these children, though the enhanced development...... in the central auditory system in early-implanted children may benefit music processing. We hypothesized that early-implanted, prelingually deaf children with CI’s, who were exposed to group-oriented music learning activities, would increase their music discrimination skills and — as a potential near transfer...

  19. PIP breast implants: rupture rate and correlation with breast cancer.

    Science.gov (United States)

    Moschetta, M; Telegrafo, M; Cornacchia, I; Vincenti, L; Ranieri, V; Cirili, A; Rella, L; Stabile Ianora, A A; Angelelli, G

    2014-01-01

    To evaluate the incidence of Poly Implant Prosthése (PIP) rupture as assessed by magnetic resonance imaging (MRI), the prevalence of the detected signs and the potential correlation with breast carcinoma. 67 patients with silicone breast implants and clinical indications for breast MRI were evaluated for a total of 125 implants: 40 (32%) PIP in 21 patients and 85 non-PIP in 46 patients (68%), the latest considered as control group. A 1.5-T MR imaging device was used in order to assess implant integrity with dedicated sequences and in 6 cases a dynamic study was performed for characterizing breast lesions. Two radiologists with more than 5 years' experience in the field of MRI evaluated in consensus all MR images searching for the presence of clear signs of intra or extra-capsular implant rupture. 20/40 (50%) PIP implants presented signs of intra-capsular rupture: linguine sign in 20 cases (100%), tear-drop sign in 6 (30%). In 12/20 cases (60%), MRI signs of extra-capsular rupture were detected. In the control group, an intra-capsular rupture was diagnosed in 12/85 cases (14%) associated with extra-capsular one in 5/12 cases (42%). Among the six cases with suspected breast lesions, in 2/21 patients with PIP implants (10%) a breast carcinoma was diagnosed (mucinous carcinoma, n=1; invasive ductal carcinoma, n=1). In 4/46 patients (9%) with non-PIP implants, an invasive ductal carcinoma was diagnosed. The rupture rate of PIP breast implants is significantly higher than non-PIP (50% vs 14%). MRI represents the most accurate imaging tool for evaluating breast prostheses and the linguine sign is the most common MRI sign to be searched. The incidence of breast carcinoma does not significantly differ between the PIP and non-PIP implants and a direct correlation with breast cancer can not been demonstrated.

  20. Patch testers' opinions regarding diagnostic criteria for metal hypersensitivity reactions to metallic implants.

    Science.gov (United States)

    Schalock, Peter C; Thyssen, Jacob P

    2013-01-01

    Metal hypersensitivity reactions to implanted devices remain a challenging and controversial topic. Diagnostic criteria and methods are not well delineated. Diagnostic criteria for hypersensitivity reactions after metallic device implantation are evaluated in this study by a multinational group of patch testers using Thyssen's previously published criteria. A total of 119 dermatologists at the 2012 European Contact Dermatitis Society and 2013 American Contact Dermatitis Society meetings answered a survey regarding their opinions on topics relating to metal hypersensitivity. Four major and 5 minor diagnostic criteria emerged. Approximately 80% of respondents found the following criteria useful (major criteria): chronic dermatitis beginning weeks to months after metallic implantation, eruption overlying the metal implant, positive patch test to a metal component of the implant, and complete clearing after removal of the potentially allergenic implant. Minor criteria (metals (eg, lymphocyte transformation test). In the challenging situation such as a symptomatic or failing orthopedic device, applying these 4 major criteria and the 5 supportive minor criteria may be useful for guiding decision making.