WorldWideScience

Sample records for total sample required

  1. Direct analysis of biological samples by total reflection X-ray fluorescence

    International Nuclear Information System (INIS)

    Lue M, Marco P.; Hernandez-Caraballo, Edwin A.

    2004-01-01

    The technique of total reflection X-ray fluorescence (TXRF) is well suited for the direct analysis of biological samples due to the low matrix interferences and simultaneous multi-element nature. Nevertheless, biological organic samples are frequently analysed after digestion procedures. The direct determination of analytes requires shorter analysis time, low reactive consumption and simplifies the whole analysis process. On the other hand, the biological/clinical samples are often available in minimal amounts and routine studies require the analysis of large number of samples. To overcome the difficulties associated with the analysis of organic samples, particularly of solid ones, different procedures of sample preparation and calibration to approach the direct analysis have been evaluated: (1) slurry sampling, (2) Compton peak standardization, (3) in situ microwave digestion, (4) in situ chemical modification and (5) direct analysis with internal standardization. Examples of analytical methods developed by our research group are discussed. Some of them have not been previously published, illustrating alternative strategies for coping with various problems that may be encountered in the direct analysis by total reflection X-ray fluorescence spectrometry

  2. Total Decomposition of Environmental Radionuclide Samples with a Microwave Oven

    International Nuclear Information System (INIS)

    Ramon Garcia, Bernd Kahn

    1998-01-01

    Closed-vessel microwave assisted acid decomposition was investigated as an alternative to traditional methods of sample dissolution/decomposition. This technique, used in analytical chemistry, has some potential advantages over other procedures. It requires less reagents, it is faster, and it has the potential of achieving total dissolution because of higher temperatures and pressures

  3. 12 CFR 932.2 - Total capital requirement.

    Science.gov (United States)

    2010-01-01

    ... 12 Banks and Banking 7 2010-01-01 2010-01-01 false Total capital requirement. 932.2 Section 932.2 Banks and Banking FEDERAL HOUSING FINANCE BOARD FEDERAL HOME LOAN BANK RISK MANAGEMENT AND CAPITAL STANDARDS FEDERAL HOME LOAN BANK CAPITAL REQUIREMENTS § 932.2 Total capital requirement. (a) Each Bank shall...

  4. Artificial Neural Network for Total Laboratory Automation to Improve the Management of Sample Dilution.

    Science.gov (United States)

    Ialongo, Cristiano; Pieri, Massimo; Bernardini, Sergio

    2017-02-01

    Diluting a sample to obtain a measure within the analytical range is a common task in clinical laboratories. However, for urgent samples, it can cause delays in test reporting, which can put patients' safety at risk. The aim of this work is to show a simple artificial neural network that can be used to make it unnecessary to predilute a sample using the information available through the laboratory information system. Particularly, the Multilayer Perceptron neural network built on a data set of 16,106 cardiac troponin I test records produced a correct inference rate of 100% for samples not requiring predilution and 86.2% for those requiring predilution. With respect to the inference reliability, the most relevant inputs were the presence of a cardiac event or surgery and the result of the previous assay. Therefore, such an artificial neural network can be easily implemented into a total automation framework to sensibly reduce the turnaround time of critical orders delayed by the operation required to retrieve, dilute, and retest the sample.

  5. Total reflection x-ray analysis of metals in blood samples

    International Nuclear Information System (INIS)

    Nakamura, Takuya; Matsui, Hiroshi; Kawamata, Masaya

    2009-01-01

    The sample preparation for TXRF (total reflection X-ray fluorescence) quantitative analysis of trace elements in human blood samples was investigated. In the TXRF analysis, a solution sample is dropped and dried on a flat substrate, and then the dried residue is measured. In this case, the dried residue should be flat not to disturb X-ray total reflection on the substrate. In addition, it is required to simply measure the whole blood sample by TXRF method, although a serum is analyzed in many cases. Thus, we studied the optimum conditions of the sample preparation of the whole blood by adding the pure water to apply Hemolysis phenomenon, where blood cells are destroyed due to different of the osmotic pressure, leading to flat residue. It was found that the best S/B ratio was obtained when the whole blood was diluted 8 times with pure water. Moreover, it was investigated the influence of the surface chemical condition of the glass substrate on the shape of the dried reside of the blood sample. When the surface of the glass substrate was hydrophilic, the shape of the dried residues was not uniform, as a result, the quantitative data of TXRF analysis gave a large deviation. On the other hand, when the surface of the glass was hydrophobic, the shape of the residue was almost uniform, as a result, a good reproducibility was obtained. Another problem was an outer ring of the dried residue of the blood. This uneven ring absorbs the primary X-rays, caused to low determined quantitative data. Thus, we tried the heating way of the dropped blood sample at a high temperature of 200 degrees. In this case, the blood sample was dried immediately, and a flat homogeneous dried residue was obtained without the outer ring. Using the optimized conditions for sample preparation, human blood sample was quantitatively measured by TXRF and ICP-AES. A good agreement was obtained in TXRF and ICP-AES determinations; however, the measurement of Cl and Br will be an advantage of TXRF, because

  6. Plasticizers in total diet samples, baby food and infant formulae

    DEFF Research Database (Denmark)

    Petersen, Jens Højslev; Breindahl, T.

    2000-01-01

    The plasticizers di-n-butylphthalate (DBP), butylbenzylphthalate (BBP), di-2-(ethylhexyl)phthalate (DEHP) and di-2-(ethylhexyl)adipate (DEHA) were analysed in 29 total diet samples, in 11 samples of baby food and in 11 samples of infant formulae. In all of the total diet samples the presence of one...... as in infant formulae. The calculated mean maximum intakes of the individual compounds from the total diet samples were below 10% of the restrictions proposed by the EU Scientific Committee for Food (SCF), and the spread in individual intakes was considerable. DEHP was the plasticizer determined most...

  7. Total and inorganic arsenic in fish samples from Norwegian waters

    DEFF Research Database (Denmark)

    Julshamn, K.; Nilsen, B. M.; Frantzen, S.

    2012-01-01

    The contents of total arsenic and inorganic arsenic were determined in fillet samples of Northeast Arctic cod, herring, mackerel, Greenland halibut, tusk, saithe and Atlantic halibut. In total, 923 individual fish samples were analysed. The fish were mostly caught in the open sea off the coast......-assisted dissolution of the samples. The concentrations found for total arsenic varied greatly between fish species, and ranged from 0.3 to 110 mg kg–1 wet weight. For inorganic arsenic, the concentrations found were very low (...

  8. 30 CFR 71.201 - Sampling; general requirements.

    Science.gov (United States)

    2010-07-01

    ... MINES Sampling Procedures § 71.201 Sampling; general requirements. (a) Each operator shall take... required by this part with a sampling device approved by the Secretary and the Secretary of Health and Human Services under part 74 (Coal Mine Dust Personal Sampler Units) of this title. (b) Sampling devices...

  9. Determination of total and methylmercury compounds in the IAEA human hair intercomparison samples - Experience of the IAEA-MEL

    International Nuclear Information System (INIS)

    Horvat, M.; Liang, L.; Mandic, V.

    1995-01-01

    The programme of this CRP is focused on the analyses of human hair samples. There are only two human hair samples certified for total mercury, and no RMs for methylmercury compounds is available. One of the main objectives of this CRP is to produce, through the IAEA AQCS Programme, a human hair intercomparison material for quality assurance requirements in population monitoring programmes for total and methylmercury exposure. Through the reporting period, MESL has introduced a new method for simultaneous determination of total and methylmercury in biological samples. As the laboratory has close collaboration with the CRP's Reference Laboratory in Ljubljana, Slovenia, it has also been actively involved in the quality assurance component of this CRP. This report represents a summary on the results for total and methylmercury in two intercomparison samples, IAEA-085 and IAEA-086 using newly developed method

  10. Predicting thyroxine requirements following total thyroidectomy.

    Science.gov (United States)

    Mistry, Dipan; Atkin, Stephen; Atkinson, Helen; Gunasekaran, Sinnappa; Sylvester, Deborah; Rigby, Alan S; England, R James

    2011-03-01

    Optimal thyroxine replacement following total thyroidectomy is critical to avoid symptoms of hypothyroidism. The aim of this study was to determine the best formula to determine the initiated replacement dose of levothyroxine immediately following total thyroidectomy. Prospective study. All patients were initiated on 100 μg levothyroxine and titrated to within the reference range for TSH and free T4. Correlations to height, weight, age, lean body mass (LBM), body surface area (BSA) and body mass index (BMI) were calculated. One hundred consecutive adult patients underwent total thyroidectomy for non-malignant disease. Comparison between three methods of levothyroxine dose prediction, aiming for a levothyroxine dose correct to within 25 μg of actual dose required. Correlations were seen between levothyroxine dose and patient age (r=-0.346, Pregression equation was calculated (predicted levothyroxine dose=[0·943 × bodyweight] + [-1.165 × age] + 125.8), simplified to (levothyroxine dose= bodyweight - age + 125) pragmatically. Initiating patients empirically on 100 μg post-operatively showed that 40% of patients achieved target within 25 μg of their required dose; this increased to 59% when using a weight-only dose calculation (1.6 μg/kg) and to 72% using the simplified regression equation. A simple calculated regression equation gives a more accurate prediction of initiated levothyroxine dose following total thyroidectomy, reducing the need for outpatient attendance for dose titration. © 2011 Blackwell Publishing Ltd.

  11. 30 CFR 70.201 - Sampling; general requirements.

    Science.gov (United States)

    2010-07-01

    ...; general requirements. (a) Each operator shall take respirable dust samples of the concentration of respirable dust in the active workings of the mine as required by this part with a sampling device approved... Personal Sampler Units) of this title. (b) Sampling devices shall be worn or carried directly to and from...

  12. Total and inorganic arsenic in fish samples from Norwegian waters.

    Science.gov (United States)

    Julshamn, Kaare; Nilsen, Bente M; Frantzen, Sylvia; Valdersnes, Stig; Maage, Amund; Nedreaas, Kjell; Sloth, Jens J

    2012-01-01

    The contents of total arsenic and inorganic arsenic were determined in fillet samples of Northeast Artic cod, herring, mackerel, Greenland halibut, tusk, saithe and Atlantic halibut. In total, 923 individual fish samples were analysed. The fish were mostly caught in the open sea off the coast of Norway, from 40 positions. The determination of total arsenic was carried out by inductively coupled plasma mass spectrometry following microwave-assisted wet digestion. The determination of inorganic arsenic was carried out by high-performance liquid chromatography-ICP-MS following microwave-assisted dissolution of the samples. The concentrations found for total arsenic varied greatly between fish species, and ranged from 0.3 to 110 mg kg(-1) wet weight. For inorganic arsenic, the concentrations found were very low (fish used in the recent EFSA opinion on arsenic in food.

  13. Predicting sample size required for classification performance

    Directory of Open Access Journals (Sweden)

    Figueroa Rosa L

    2012-02-01

    Full Text Available Abstract Background Supervised learning methods need annotated data in order to generate efficient models. Annotated data, however, is a relatively scarce resource and can be expensive to obtain. For both passive and active learning methods, there is a need to estimate the size of the annotated sample required to reach a performance target. Methods We designed and implemented a method that fits an inverse power law model to points of a given learning curve created using a small annotated training set. Fitting is carried out using nonlinear weighted least squares optimization. The fitted model is then used to predict the classifier's performance and confidence interval for larger sample sizes. For evaluation, the nonlinear weighted curve fitting method was applied to a set of learning curves generated using clinical text and waveform classification tasks with active and passive sampling methods, and predictions were validated using standard goodness of fit measures. As control we used an un-weighted fitting method. Results A total of 568 models were fitted and the model predictions were compared with the observed performances. Depending on the data set and sampling method, it took between 80 to 560 annotated samples to achieve mean average and root mean squared error below 0.01. Results also show that our weighted fitting method outperformed the baseline un-weighted method (p Conclusions This paper describes a simple and effective sample size prediction algorithm that conducts weighted fitting of learning curves. The algorithm outperformed an un-weighted algorithm described in previous literature. It can help researchers determine annotation sample size for supervised machine learning.

  14. Differences in sampling techniques on total post-mortem tryptase.

    Science.gov (United States)

    Tse, R; Garland, J; Kesha, K; Elstub, H; Cala, A D; Ahn, Y; Stables, S; Palmiere, C

    2017-11-20

    The measurement of mast cell tryptase is commonly used to support the diagnosis of anaphylaxis. In the post-mortem setting, the literature recommends sampling from peripheral blood sources (femoral blood) but does not specify the exact sampling technique. Sampling techniques vary between pathologists, and it is unclear whether different sampling techniques have any impact on post-mortem tryptase levels. The aim of this study is to compare the difference in femoral total post-mortem tryptase levels between two sampling techniques. A 6-month retrospective study comparing femoral total post-mortem tryptase levels between (1) aspirating femoral vessels with a needle and syringe prior to evisceration and (2) femoral vein cut down during evisceration. Twenty cases were identified, with three cases excluded from analysis. There was a statistically significant difference (paired t test, p sampling methods. The clinical significance of this finding and what factors may contribute to it are unclear. When requesting post-mortem tryptase, the pathologist should consider documenting the exact blood collection site and method used for collection. In addition, blood samples acquired by different techniques should not be mixed together and should be analyzed separately if possible.

  15. AAS determination of total mercury content in environmental samples

    International Nuclear Information System (INIS)

    Moskalova, M.; Zemberyova, M.

    1997-01-01

    Two methods for determination of total mercury content in environmental samples soils, and sediments, were compared. Dissolution procedure of soils, sediments, and biological material under elevated pressure followed by determination of mercury by cold vapour atomic absorption spectrometry using a MHS-1 system and direct total mercury determination without any chemical pretreatment from soil samples using a Trace Mercury Analyzer TMA-254 were compared. TMA-254 was also applied for the determination of mercury in various further standard reference materials. Good agreement with certified values of environmental reference materials was obtained. (authors)

  16. Determination of nitrite, nitrate and total nitrogen in vegetable samples

    Directory of Open Access Journals (Sweden)

    Manas Kanti Deb

    2007-04-01

    Full Text Available Yellow diazonium cation formed by reaction of nitrite with 6-amino-1-naphthol-3-sulphonic acid is coupled with β-naphthol in strong alkaline medium to yield a pink coloured azo dye. The azo-dyes shows absorption maximum at 510 nm with molar absorptivity of 2.5 ×104 M-1 cm-1. The dye product obeys Beer's law (correlation coefficient = 0.997, in terms of nitrite concentration, up to 2.7 μg NO2 mL-1. The above colour reaction system has been applied successfully for the determination of nitrite, nitrate and total nitrogen in vegetable samples. Unreduced samples give direct measure for nitrite whilst reduction of samples by copperized-cadmium column gives total nitrogen content and their difference shows nitrate content in the samples. Variety of vegetables have been tested for their N-content (NO2-/NO3-/total-N with % RSD ranging between 1.5 to 2.5 % for nitrite determination. The effects of foreign ions in the determination of the nitrite, nitrate, and total nitrogen have been studied. Statistical comparison of the results with those of reported method shows good agreement and indicates no significant difference in precision.

  17. Total CMB analysis of streaker aerosol samples by PIXE, PIGE, beta- and optical-absorption analyses

    International Nuclear Information System (INIS)

    Annegarn, H.J.; Przybylowicz, W.J.

    1993-01-01

    Multielemental analyses of aerosol samples are widely used in air pollution receptor modelling. Specifically, the chemical mass balance (CMB) model has become a powerful tool in urban air quality studies. Input data required for the CMB includes not only the traditional X-ray fluorescence (and hence PIXE) detected elements, but also total mass, organic and inorganic carbon, and other light elements including Mg, Na and F. The circular streaker sampler, in combination with PIXE analysis, has developed into a powerful tool for obtaining time-resolved, multielemental aerosol data. However, application in CMB modelling has been limited by the absence of total mass and complementary light element data. This study reports on progress in using techniques complementary to PIXE to obtain additional data from circular streaker samples, maintaining the nondestructive, instrumental approach inherent in PIXE: Beta-gauging using a 147 Pm source for total mass; optical absorption for inorganic carbon; and PIGE to measure the lighter elements. (orig.)

  18. 30 CFR 75.336 - Sampling and monitoring requirements.

    Science.gov (United States)

    2010-07-01

    ... concentration of other sampling locations in the sealed area and other required information. Before miners... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Sampling and monitoring requirements. 75.336... SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Ventilation § 75.336 Sampling and...

  19. TruSeq Stranded mRNA and Total RNA Sample Preparation Kits

    Science.gov (United States)

    Total RNA-Seq enabled by ribosomal RNA (rRNA) reduction is compatible with formalin-fixed paraffin embedded (FFPE) samples, which contain potentially critical biological information. The family of TruSeq Stranded Total RNA sample preparation kits provides a unique combination of unmatched data quality for both mRNA and whole-transcriptome analyses, robust interrogation of both standard and low-quality samples and workflows compatible with a wide range of study designs.

  20. A Comparison of "Total Dust" and Inhalable Personal Sampling for Beryllium Exposure

    Energy Technology Data Exchange (ETDEWEB)

    Carter, Colleen M. [Tulane Univ., New Orleans, LA (United States). School of Public Health and Tropical Medicine

    2012-05-09

    In 2009, the American Conference of Governmental Industrial Hygienists (ACGIH) reduced the Beryllium (Be) 8-hr Time Weighted Average Threshold Limit Value (TLV-TWA) from 2.0 μg/m3 to 0.05 μg/m3 with an inhalable 'I' designation in accordance with ACGIH's particle size-selective criterion for inhalable mass. Currently, per the Department of Energy (DOE) requirements, the Lawrence Livermore National Laboratory (LLNL) is following the Occupational Health and Safety Administration (OSHA) Permissible Exposure Limit (PEL) of 2.0 μg/m3 as an 8-hr TWA, which is also the 2005 ACGIH TLV-TWA, and an Action Level (AL) of 0.2 μg/m3 and sampling is performed using the 37mm (total dust) sampling method. Since DOE is considering adopting the newer 2009 TLV guidelines, the goal of this study was to determine if the current method of sampling using the 37mm (total dust) sampler would produce results that are comparable to what would be measured using the IOM (inhalable) sampler specific to the application of high energy explosive work at LLNL's remote experimental test facility at Site 300. Side-by-side personal sampling using the two samplers was performed over an approximately two-week period during chamber re-entry and cleanup procedures following detonation of an explosive assembly containing Beryllium (Be). The average ratio of personal sampling results for the IOM (inhalable) vs. 37-mm (total dust) sampler was 1.1:1 with a P-value of 0.62, indicating that there was no statistically significant difference in the performance of the two samplers. Therefore, for the type of activity monitored during this study, the 37-mm sampling cassette would be considered a suitable alternative to the IOM sampler for collecting inhalable particulate matter, which is important given the many practical and economic advantages that it presents. However, similar comparison studies would be necessary for this conclusion to be

  1. Microwave-Assisted Sample Treatment in a Fully Automated Flow-Based Instrument: Oxidation of Reduced Technetium Species in the Analysis of Total Technetium-99 in Caustic Aged Nuclear Waste Samples

    International Nuclear Information System (INIS)

    Egorov, Oleg B.; O'Hara, Matthew J.; Grate, Jay W.

    2004-01-01

    An automated flow-based instrument for microwave-assisted treatment of liquid samples has been developed and characterized. The instrument utilizes a flow-through reaction vessel design that facilitates the addition of multiple reagents during sample treatment, removal of the gaseous reaction products, and enables quantitative removal of liquids from the reaction vessel for carryover-free operations. Matrix modification and speciation control chemistries that are required for the radiochemical determination of total 99Tc in caustic aged nuclear waste samples have been investigated. A rapid and quantitative oxidation procedure using peroxydisulfate in acidic solution was developed to convert reduced technetium species to pertechnetate in samples with high content of reducing organics. The effectiveness of the automated sample treatment procedures has been validated in the radiochemical analysis of total 99Tc in caustic aged nuclear waste matrixes from the Hanford site

  2. 40 CFR 141.174 - Filtration sampling requirements.

    Science.gov (United States)

    2010-07-01

    ... PROGRAMS (CONTINUED) NATIONAL PRIMARY DRINKING WATER REGULATIONS Enhanced Filtration and Disinfection... water system subject to the requirements of this subpart that provides conventional filtration treatment... 40 Protection of Environment 22 2010-07-01 2010-07-01 false Filtration sampling requirements. 141...

  3. Required sample size for monitoring stand dynamics in strict forest reserves: a case study

    Science.gov (United States)

    Diego Van Den Meersschaut; Bart De Cuyper; Kris Vandekerkhove; Noel Lust

    2000-01-01

    Stand dynamics in European strict forest reserves are commonly monitored using inventory densities of 5 to 15 percent of the total surface. The assumption that these densities guarantee a representative image of certain parameters is critically analyzed in a case study for the parameters basal area and stem number. The required sample sizes for different accuracy and...

  4. Quality control on the accuracy of the total Beta activity index in different sample matrices water

    International Nuclear Information System (INIS)

    Pujol, L.; Pablo, M. A. de; Payeras, J.

    2013-01-01

    The standard ISO/IEC 17025:2005 of general requirements for the technical competence of testing and calibration laboratories, provides that a laboratory shall have quality control procedures for monitoring the validity of tests and calibrations ago. In this paper, the experience of Isotopic Applications Laboratory (CEDEX) in controlling the accuracy rate of total beta activity in samples of drinking water, inland waters and marine waters is presented. (Author)

  5. Method validation to determine total alpha beta emitters in water samples using LSC

    International Nuclear Information System (INIS)

    Al-Masri, M. S.; Nashawati, A.; Al-akel, B.; Saaid, S.

    2006-06-01

    In this work a method was validated to determine gross alpha and beta emitters in water samples using liquid scintillation counter. 200 ml of water from each sample were evaporated to 20 ml and 8 ml of them were mixed with 12 ml of the suitable cocktail to be measured by liquid scintillation counter Wallac Winspectral 1414. The lower detection limit by this method (LDL) was 0.33 DPM for total alpha emitters and 1.3 DPM for total beta emitters. and the reproducibility limit was (± 2.32 DPM) and (±1.41 DPM) for total alpha and beta emitters respectively, and the repeatability limit was (±2.19 DPM) and (±1.11 DPM) for total alpha and beta emitters respectively. The method is easy and fast because of the simple preparation steps and the large number of samples that can be measured at the same time. In addition, many real samples and standard samples were analyzed by the method and showed accurate results so it was concluded that the method can be used with various water samples. (author)

  6. Iodide-assisted total lead measurement and determination of different lead fractions in drinking water samples.

    Science.gov (United States)

    Zhang, Yuanyuan; Ng, Ding-Quan; Lin, Yi-Pin

    2012-07-01

    Lead and its compounds are toxic and can harm human health, especially the intelligence development in children. Accurate measurement of total lead present in drinking water is crucial in determining the extent of lead contamination and human exposure due to drinking water consumption. The USEPA method for total lead measurement (no. 200.8) is often used to analyze lead levels in drinking water. However, in the presence of high concentration of the tetravalent lead corrosion product PbO(2), the USEPA method was not able to fully recover particulate lead due to incomplete dissolution of PbO(2) particles during strong acid digestion. In this study, a new procedure that integrates membrane separation, iodometric PbO(2) measurement, strong acid digestion and ICP-MS measurement was proposed and evaluated for accurate total lead measurement and quantification of different lead fractions including soluble Pb(2+), particulate Pb(II) carbonate and PbO(2) in drinking water samples. The proposed procedure was evaluated using drinking water reconstituted with spiked Pb(2+), spiked particulate Pb(II) carbonate and in situ formed or spiked PbO(2). Recovery tests showed that the proposed procedure and the USEPA method can achieve 93-112% and 86-103% recoveries respectively for samples containing low PbO(2) concentrations (0.018-0.076 mg Pb per L). For samples containing higher concentrations of PbO(2) (0.089-1.316 mg Pb per L), the USEPA method failed to meet the recovery requirement for total lead (85-115%) while the proposed method can achieve satisfactory recoveries (91-111%) and differentiate the soluble Pb(2+), particulate Pb(II) carbonate and PbO(2).

  7. Apparatus and method for quantitatively evaluating total fissile and total fertile nuclide content in samples

    International Nuclear Information System (INIS)

    Caldwell, J.T.; Cates, M.R.; Franks, L.A.; Kunz, W.E.

    1985-01-01

    Simultaneous photon and neutron interrogation of samples for the quantitative determination of total fissile nuclide and total fertile nuclide material present is made possible by the use of an electron accelerator. Prompt and delayed neutrons produced from resulting induced fissions are counted using a single detection system and allow the resolution of the contributions from each interrogating flux leading in turn to the quantitative determination sought. Detection limits for 239 Pu are estimated to be about 3 mg using prompt fission neutrons and about 6 mg using delayed delayed neutrons

  8. 40 CFR 141.22 - Turbidity sampling and analytical requirements.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 22 2010-07-01 2010-07-01 false Turbidity sampling and analytical... § 141.22 Turbidity sampling and analytical requirements. The requirements in this section apply to... the water distribution system at least once per day, for the purposes of making turbidity measurements...

  9. Critique of Hanford Waste Vitrification Plant off-gas sampling requirements

    International Nuclear Information System (INIS)

    Goles, R.W.

    1996-03-01

    Off-gas sampling and monitoring activities needed to support operations safety, process control, waste form qualification, and environmental protection requirements of the Hanford Waste Vitrification Plant (HWVP) have been evaluated. The locations of necessary sampling sites have been identified on the basis of plant requirements, and the applicability of Defense Waste Processing Facility (DWPF) reference sampling equipment to these HWVP requirements has been assessed for all sampling sites. Equipment deficiencies, if present, have been described and the bases for modifications and/or alternative approaches have been developed

  10. Training Requirements and Training Delivery in the Total Army School System

    National Research Council Canada - National Science Library

    Winkler, John

    1999-01-01

    This report analyzes training requirements and school delivery of training in the Total Army School System, focusing on the system's ability to meet its training requirements in Reserve Component Training Institutions...

  11. Total Arsenic, Cadmium, and Lead Determination in Brazilian Rice Samples Using ICP-MS.

    Science.gov (United States)

    Mataveli, Lidiane Raquel Verola; Buzzo, Márcia Liane; de Arauz, Luciana Juncioni; Carvalho, Maria de Fátima Henriques; Arakaki, Edna Emy Kumagai; Matsuzaki, Richard; Tiglea, Paulo

    2016-01-01

    This study is aimed at investigating a suitable method for rice sample preparation as well as validating and applying the method for monitoring the concentration of total arsenic, cadmium, and lead in rice by using Inductively Coupled Plasma Mass Spectrometry (ICP-MS). Various rice sample preparation procedures were evaluated. The analytical method was validated by measuring several parameters including limit of detection (LOD), limit of quantification (LOQ), linearity, relative bias, and repeatability. Regarding the sample preparation, recoveries of spiked samples were within the acceptable range from 89.3 to 98.2% for muffle furnace, 94.2 to 103.3% for heating block, 81.0 to 115.0% for hot plate, and 92.8 to 108.2% for microwave. Validation parameters showed that the method fits for its purpose, being the total arsenic, cadmium, and lead within the Brazilian Legislation limits. The method was applied for analyzing 37 rice samples (including polished, brown, and parboiled), consumed by the Brazilian population. The total arsenic, cadmium, and lead contents were lower than the established legislative values, except for total arsenic in one brown rice sample. This study indicated the need to establish monitoring programs for emphasizing the study on this type of cereal, aiming at promoting the Public Health.

  12. Total Arsenic, Cadmium, and Lead Determination in Brazilian Rice Samples Using ICP-MS

    Directory of Open Access Journals (Sweden)

    Lidiane Raquel Verola Mataveli

    2016-01-01

    Full Text Available This study is aimed at investigating a suitable method for rice sample preparation as well as validating and applying the method for monitoring the concentration of total arsenic, cadmium, and lead in rice by using Inductively Coupled Plasma Mass Spectrometry (ICP-MS. Various rice sample preparation procedures were evaluated. The analytical method was validated by measuring several parameters including limit of detection (LOD, limit of quantification (LOQ, linearity, relative bias, and repeatability. Regarding the sample preparation, recoveries of spiked samples were within the acceptable range from 89.3 to 98.2% for muffle furnace, 94.2 to 103.3% for heating block, 81.0 to 115.0% for hot plate, and 92.8 to 108.2% for microwave. Validation parameters showed that the method fits for its purpose, being the total arsenic, cadmium, and lead within the Brazilian Legislation limits. The method was applied for analyzing 37 rice samples (including polished, brown, and parboiled, consumed by the Brazilian population. The total arsenic, cadmium, and lead contents were lower than the established legislative values, except for total arsenic in one brown rice sample. This study indicated the need to establish monitoring programs for emphasizing the study on this type of cereal, aiming at promoting the Public Health.

  13. 40 CFR 761.130 - Sampling requirements.

    Science.gov (United States)

    2010-07-01

    ... 761.130 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) TOXIC SUBSTANCES CONTROL... sampling scheme is that it is designed to characterize the degree of contamination within the entire.... For this purpose, the numerical level of cleanup required for spills cleaned in accordance with § 761...

  14. Development of improved space sampling strategies for ocean chemical properties: Total carbon dioxide and dissolved nitrate

    Science.gov (United States)

    Goyet, Catherine; Davis, Daniel; Peltzer, Edward T.; Brewer, Peter G.

    1995-01-01

    Large-scale ocean observing programs such as the Joint Global Ocean Flux Study (JGOFS) and the World Ocean Circulation Experiment (WOCE) today, must face the problem of designing an adequate sampling strategy. For ocean chemical variables, the goals and observing technologies are quite different from ocean physical variables (temperature, salinity, pressure). We have recently acquired data on the ocean CO2 properties on WOCE cruises P16c and P17c that are sufficiently dense to test for sampling redundancy. We use linear and quadratic interpolation methods on the sampled field to investigate what is the minimum number of samples required to define the deep ocean total inorganic carbon (TCO2) field within the limits of experimental accuracy (+/- 4 micromol/kg). Within the limits of current measurements, these lines were oversampled in the deep ocean. Should the precision of the measurement be improved, then a denser sampling pattern may be desirable in the future. This approach rationalizes the efficient use of resources for field work and for estimating gridded (TCO2) fields needed to constrain geochemical models.

  15. The analysis of Th in the Korean total diet sample by RNAA

    International Nuclear Information System (INIS)

    Chung, Yong Sam; Moon, Jong Hwa; Kang, Sang Hoon; Park, Kwang Won

    1999-01-01

    In order to estimate the degree of intake of 232 Th through daily diet, a korean total diet sample was collected and made after the investigation of the amount of consumption of daily diet which is dependent on the ages of 20's to 50's. For Th analysis, the RNAA method was applied and NIST SRM 1575, Pine Needle was used as quality control materials. The result of the SRM analysis was compared with a certified value. The relative error was 5%. The determination of the Th in the korean total diet sample was carried out under the same analytical condition and procedure with SRM. As a result of the korean total diet sample, the concentration of Th was in 3.4 ± 0.2 ppb and the amount of daily intake of Th by the diet is found to be 0.67 g per day. Radioactivity by Th intake was estimated to be about 2.7 mBq per person per day and annual dose equivalent was revealed as 0.73 μSv per person

  16. Multielement analysis of aerosol samples by X-ray fluorescence analysis with totally reflecting sample holders

    International Nuclear Information System (INIS)

    Ketelsen, P.; Knoechel, A.

    1984-01-01

    Aerosole samples on filter support were analyzed using the X-ray flourescence analytical method (Mo excitation) with totally reflecting sample carrier (TXFA). Wet decomposition of the sample material with HNO 3 in an enclosed system and subsequent sample preparation by evaporating an aliquot of the solution on the sample carrier yields detection limits up to 0.3 ng/cm 2 . The reproducibilities of the measurements of the elements K, Ca, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn, As, Se, Rb, Sr, Ba and Pb lie between 5 and 25%. Similar detection limits and reproducibilities are obtained, when low-temperature oxygen plasma is employed for the direct ashing of the homogenously covered filter on the sample carrier. For the systematic loss of elements both methods were investigated with radiotracers as well as with inactive techniques. A comparison of the results with those obtained by NAA, AAS and PIXE shows good agreement in most cases. For the bromine determination and the fast coverage of the main elements a possibility for measuring the filter membrane has been indicated, which neglects the ashing step. The corresponding detection limits are up to 3 ng/cm 2 . (orig.) [de

  17. 21 CFR 111.83 - What are the requirements for reserve samples?

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 2 2010-04-01 2010-04-01 false What are the requirements for reserve samples? 111..., PACKAGING, LABELING, OR HOLDING OPERATIONS FOR DIETARY SUPPLEMENTS Requirement to Establish a Production and Process Control System § 111.83 What are the requirements for reserve samples? (a) You must collect and...

  18. Open focused microwave-assisted sample preparation for rapid total and mercury species determination in environmental solid samples

    OpenAIRE

    Tseng, C. M.; Garraud, H.; Amouroux, D.; Donard, O. F. X.; de Diego, A.

    1998-01-01

    This paper describes rapid, simple microwave-assisted leaching/ digestion procedures for total and mercury species determination in sediment samples and biomaterials. An open focused microwave system allowed the sample preparation time to be dramatically reduced to only 24 min when a power of 40-80 W was applied. Quantitative leaching of methylmercury from sediments by HNO3 solution and complete dissolution of biomaterials by an alkaline solution, such as 25% TMAH solution, were obtained. Met...

  19. Determination of arsenic in water samples by Total Reflection X-Ray Fluorescence using pre-concentration with alumina

    Energy Technology Data Exchange (ETDEWEB)

    Barros, Haydn [Laboratorio de Fisica Nuclear, Dpto. De Fisica, Universidad Simon Bolivar, Sartenejas, Baruta (Venezuela, Bolivarian Republic of); Marco Parra, Lue-Meru, E-mail: luemerumarco@yahoo.e [Universidad Centroccidental Lisandro Alvarado, Dpto. Quimica y Suelos, Decanato de Agronomia, Tarabana, Cabudare, Edo.Lara (Venezuela, Bolivarian Republic of); Bennun, Leonardo [Universidad de Concepcion, Concepcion (Chile); Greaves, Eduardo D. [Laboratorio de Fisica Nuclear, Dpto. De Fisica, Universidad Simon Bolivar, Sartenejas, Baruta (Venezuela, Bolivarian Republic of)

    2010-06-15

    The determination of arsenic in water samples requires techniques of high sensitivity. Total Reflection X-Ray Fluorescence (TXRF) allows the determination but a prior separation and pre-concentration procedure is necessary. Alumina is a suitable substrate for the selective separation of the analytes. A method for separation and pre-concentration in alumina, followed by direct analysis of the alumina is evaluated. Quantification was performed using the Al-K{alpha} and Co-K{alpha} lines as internal standard in samples prepared on an alumina matrix, and compared to a calibration with aqueous standards. Artificial water samples of As (III) and As (V) were analyzed after the treatment. Fifty milliliters of the sample at ppb concentration levels were mixed with 10 mg of alumina. The pH, time and temperature were controlled. The alumina was separated from the slurry by centrifugation, washed with de-ionized water and analyzed directly on the sample holder. A pre-concentration factor of 100 was found, with detection limit of 0.7 {mu}gL{sup -1}. The percentage of recovery was 98% for As (III) and 95% for As (V) demonstrating the suitability of the procedure.

  20. Determination of arsenic in water samples by Total Reflection X-Ray Fluorescence using pre-concentration with alumina

    International Nuclear Information System (INIS)

    Barros, Haydn; Marco Parra, Lue-Meru; Bennun, Leonardo; Greaves, Eduardo D.

    2010-01-01

    The determination of arsenic in water samples requires techniques of high sensitivity. Total Reflection X-Ray Fluorescence (TXRF) allows the determination but a prior separation and pre-concentration procedure is necessary. Alumina is a suitable substrate for the selective separation of the analytes. A method for separation and pre-concentration in alumina, followed by direct analysis of the alumina is evaluated. Quantification was performed using the Al-Kα and Co-Kα lines as internal standard in samples prepared on an alumina matrix, and compared to a calibration with aqueous standards. Artificial water samples of As (III) and As (V) were analyzed after the treatment. Fifty milliliters of the sample at ppb concentration levels were mixed with 10 mg of alumina. The pH, time and temperature were controlled. The alumina was separated from the slurry by centrifugation, washed with de-ionized water and analyzed directly on the sample holder. A pre-concentration factor of 100 was found, with detection limit of 0.7 μgL -1 . The percentage of recovery was 98% for As (III) and 95% for As (V) demonstrating the suitability of the procedure.

  1. Analysis of biological slurry samples by total x-ray fluorescence after in situ microwave digestion

    International Nuclear Information System (INIS)

    Lue-Meru, M.P.; Capote, T.; Greaves, E.

    2000-01-01

    Biological slurry samples were analyzed by total reflection x-ray fluorescence (TXRF) after an in situ microwave digestion procedure on the quartz reflector. This method lead to the removal of the matrix by the digestion and permits the enrichment of the analites by using sample amounts higher than those normally used in TXRF for the thin layer requirement since the organic matrix is removed. In consequence, the pre-concentration of sample is performed and the detection capability is increased by a quasi direct method. The samples analyzed were the international IAEA blood standard, the SRM bovine liver 1577-a standard and fresh onion tissues. Slurries were prepared in three ways: a.- weighing a sample amount on the reflector and adding suprapure nitric acid and internal standard followed by microwave digestion, b.-weighing a sample amount and water with an appropriate concentration of the internal standard in an Eppendorf vial, taking then an aliquot to the quartz reflector for microwave digestion with suprapure nitric acid, c.- weighing a sample amount of fresh tissue, homogenising with high speed homegenator to obtain a slurry sample which can be diluted in an ependorf vial with water an the internal standard. Then an aliquot is taken to the reflector for microwave digestion with suprapure nitric acid. Further details of sample preparation procedures will be discussed during presentation. The analysis was carried out in a Canberra spectrometer using the Kalpha lines of the Ag and Mo tubes. The elements Ca, K, Fe, Cu, Zn, Se, Mn, Rb, Br, Sr were determined. The effect of the preparation procedure was evaluated by the accuracy and precision of the results for each element and the percent of recovery. (author)

  2. Total reflection X-ray fluorescence with synchrotron radiation applied to biological and environmental samples

    International Nuclear Information System (INIS)

    Simabuco, S.M.; Matsumoto, E.; Jesus, E.F.O.; Lopes, R.T.; Perez, C.; Nascimento Filho, V.F.; Costa, R.S.S.; Tavares do Carmo, M.G.; Saunders, C.

    2001-01-01

    Full text: The Total Reflection X-ray Fluorescence has been applied for trace elements in water and aqueous solutions, environmental samples and biological materials after sample preparation and to surface analysis of silicon wafers. The present paper shows some results of applications for rainwater, atmospheric particulate material, colostrum and nuclear samples. (author)

  3. Application of Total Quality Management (TQM Requirements in Risk Management in Construction Projects in Iraq

    Directory of Open Access Journals (Sweden)

    Entisar K. Al-Geelawee

    2016-06-01

    Full Text Available Total quality management considers one of the modern scientific entrances which practiced by productivity service organizations alike to provide appropriate quality required outputs according to the needs and desires of customers manage , enable the organization seeking to continue and grow in light of the increasing competition from the satisfy and provide the appropriate total quality management requirements whenever led to face risks that they may have in a manner in which they can be addressed and find ways to avoid them in the future when repeated. The research has consist of two main parts firstly have included a review of the most important concepts of total quality management in addition to the concept of risk analysis and management in construction projects and how to apply the concept of total quality management in the risk analysis and management. Second part included the practical part of the research, which was open and closed questionnaire for experts in the construction industry to obtain required informations for the application of total quality management requirements in risk management in construction projects in Iraq. One of the main findings of the research is that top management support has a high impact on risk management in addition to continuous improvement, training and education, while the participation of all employees in the organization and constant stimulation and focusing on the customer as one of the total quality management requirements had a moderate impact on risk management.

  4. Descriptive display of total alpha, energetics, TOC, oxlate as TOC, and H2O sample data from Hanford waste tanks

    International Nuclear Information System (INIS)

    SIMPSON, B.C.

    1999-01-01

    In March 1999, staff at Lockheed Makn Hanford Company (LMHC) were asked to make a presentation to the Defense Nuclear Facilities Safety Board (DNFSB) about the safety of the waste tanks at the Hanford Site and the necessity for further tank sampling. Pacific Northwest National Laboratory provided a statistical analysis of available tank data to help determine whether additional sampling would in fact be required. The analytes examined were total alpha, energetics, total organic carbon (TOC), oxalate as TOC and moisture. These analytes serve as indicators of the stability of tank contents; if any of them fall above or below certain values, further investigation is warranted (Dukelow et al. 1995). PNNL performed an analysis of the data collected on these safety screening analytes with respect to empirical distributions and the established Safety Screening Data Quality Objectives (SS DQO) thresholds and Basis for Interim Operations (BIO) limits. Both univariate and bivariate analyses were performed. Summary statistics and graphical representations of the data were generated

  5. Quantification of total aluminium concentrations in food samples at trace levels by INAA and PIGE methods

    International Nuclear Information System (INIS)

    Nanda, Braja B.; Acharya, R.

    2017-01-01

    Total aluminium contents in various food samples were determined by Instrumental Neutron Activation Analysis (INAA) and Particle Induced Gamma-ray Emission (PIGE) methods. A total of 16 rice samples, collected from the field, were analyzed by INAA using reactor neutrons from Dhruva reactor. Whereas a total 17 spices collected from market, were analyzed by both INAA and PIGE methods in conjunction with high resolution gamma-ray spectrometry. Aluminium concentration values were found to be in the range of 19-845 mg kg -1 for spices and 15-104 mg kg -1 for rice samples. The methods were validated by analyzing standard reference materials (SRMs) form NIST. (author)

  6. Determination of total mercury for marine environmental monitoring studies by solid sampling continuum source high resolution atomic absorption spectrometry

    Science.gov (United States)

    Mandjukov, Petko; Orani, Anna Maria; Han, Eunmi; Vassileva, Emilia

    2015-01-01

    The most critical step in almost all commonly used analytical procedures for Hg determination is the sample preparation due to its extreme volatility. One of the possible solutions of this problem is the application of methods for direct analysis of solid samples. The possibilities for solid sampling high resolution continuum source atomic absorption spectrometry (HR CS AAS) determination of total mercury in various marine environmental samples e.g. sediments and biota are object of the present study. The instrumental parameters were optimized in order to obtain reproducible and interference free analytical signal. A calibration technique based on the use of solid standard certified reference materials similar to the nature of the analyzed sample was developed and applied to various CRMs and real samples. This technique allows simple and reliable evaluation of the uncertainty of the result and the metrological characteristics of the method. A validation approach in line with the requirements of ISO 17025 standard and Eurachem guidelines was followed. With this in mind, selectivity, working range (0.06 to 25 ng for biota and 0.025 to 4 ng for sediment samples, expressed as total Hg) linearity (confirmed by Student's t-test), bias (1.6-4.3%), repeatability (4-9%), reproducibility (9-11%), and absolute limit of detection (0.025 ng for sediment, 0.096 ng for marine biota) were systematically assessed using solid CRMs. The relative expanded uncertainty was estimated at 15% for sediment sample and 8.5% for marine biota sample (k = 2). Demonstration of traceability of measurement results is also presented. The potential of the proposed analytical procedure, based on solid sampling HR CS AAS technique was demonstrated by direct analysis of sea sediments form the Caribbean region and various CRMs. Overall, the use of solid sampling HR CS AAS permits obtaining significant advantages for the determination of this complex analyte in marine samples, such as straightforward

  7. Determination of total concentration of chemically labeled metabolites as a means of metabolome sample normalization and sample loading optimization in mass spectrometry-based metabolomics.

    Science.gov (United States)

    Wu, Yiman; Li, Liang

    2012-12-18

    For mass spectrometry (MS)-based metabolomics, it is important to use the same amount of starting materials from each sample to compare the metabolome changes in two or more comparative samples. Unfortunately, for biological samples, the total amount or concentration of metabolites is difficult to determine. In this work, we report a general approach of determining the total concentration of metabolites based on the use of chemical labeling to attach a UV absorbent to the metabolites to be analyzed, followed by rapid step-gradient liquid chromatography (LC) UV detection of the labeled metabolites. It is shown that quantification of the total labeled analytes in a biological sample facilitates the preparation of an appropriate amount of starting materials for MS analysis as well as the optimization of the sample loading amount to a mass spectrometer for achieving optimal detectability. As an example, dansylation chemistry was used to label the amine- and phenol-containing metabolites in human urine samples. LC-UV quantification of the labeled metabolites could be optimally performed at the detection wavelength of 338 nm. A calibration curve established from the analysis of a mixture of 17 labeled amino acid standards was found to have the same slope as that from the analysis of the labeled urinary metabolites, suggesting that the labeled amino acid standard calibration curve could be used to determine the total concentration of the labeled urinary metabolites. A workflow incorporating this LC-UV metabolite quantification strategy was then developed in which all individual urine samples were first labeled with (12)C-dansylation and the concentration of each sample was determined by LC-UV. The volumes of urine samples taken for producing the pooled urine standard were adjusted to ensure an equal amount of labeled urine metabolites from each sample was used for the pooling. The pooled urine standard was then labeled with (13)C-dansylation. Equal amounts of the (12)C

  8. 21 CFR 203.32 - Drug sample storage and handling requirements.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 4 2010-04-01 2010-04-01 false Drug sample storage and handling requirements. 203.32 Section 203.32 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... contamination, deterioration, and adulteration. (b) Compliance with compendial and labeling requirements...

  9. Sampling Errors in Monthly Rainfall Totals for TRMM and SSM/I, Based on Statistics of Retrieved Rain Rates and Simple Models

    Science.gov (United States)

    Bell, Thomas L.; Kundu, Prasun K.; Einaudi, Franco (Technical Monitor)

    2000-01-01

    Estimates from TRMM satellite data of monthly total rainfall over an area are subject to substantial sampling errors due to the limited number of visits to the area by the satellite during the month. Quantitative comparisons of TRMM averages with data collected by other satellites and by ground-based systems require some estimate of the size of this sampling error. A method of estimating this sampling error based on the actual statistics of the TRMM observations and on some modeling work has been developed. "Sampling error" in TRMM monthly averages is defined here relative to the monthly total a hypothetical satellite permanently stationed above the area would have reported. "Sampling error" therefore includes contributions from the random and systematic errors introduced by the satellite remote sensing system. As part of our long-term goal of providing error estimates for each grid point accessible to the TRMM instruments, sampling error estimates for TRMM based on rain retrievals from TRMM microwave (TMI) data are compared for different times of the year and different oceanic areas (to minimize changes in the statistics due to algorithmic differences over land and ocean). Changes in sampling error estimates due to changes in rain statistics due 1) to evolution of the official algorithms used to process the data, and 2) differences from other remote sensing systems such as the Defense Meteorological Satellite Program (DMSP) Special Sensor Microwave/Imager (SSM/I), are analyzed.

  10. Analysis of parallel optical sampling rate and ADC requirements in digital coherent receivers

    DEFF Research Database (Denmark)

    Lorences Riesgo, Abel; Galili, Michael; Peucheret, Christophe

    2012-01-01

    We comprehensively assess analog-to-digital converter requirements in coherent digital receiver schemes with parallel optical sampling. We determine the electronic requirements in accordance with the properties of the free running local oscillator.......We comprehensively assess analog-to-digital converter requirements in coherent digital receiver schemes with parallel optical sampling. We determine the electronic requirements in accordance with the properties of the free running local oscillator....

  11. Sampling methods

    International Nuclear Information System (INIS)

    Loughran, R.J.; Wallbrink, P.J.; Walling, D.E.; Appleby, P.G.

    2002-01-01

    Methods for the collection of soil samples to determine levels of 137 Cs and other fallout radionuclides, such as excess 210 Pb and 7 Be, will depend on the purposes (aims) of the project, site and soil characteristics, analytical capacity, the total number of samples that can be analysed and the sample mass required. The latter two will depend partly on detector type and capabilities. A variety of field methods have been developed for different field conditions and circumstances over the past twenty years, many of them inherited or adapted from soil science and sedimentology. The use of them inherited or adapted from soil science and sedimentology. The use of 137 Cs in erosion studies has been widely developed, while the application of fallout 210 Pb and 7 Be is still developing. Although it is possible to measure these nuclides simultaneously, it is common for experiments to designed around the use of 137 Cs along. Caesium studies typically involve comparison of the inventories found at eroded or sedimentation sites with that of a 'reference' site. An accurate characterization of the depth distribution of these fallout nuclides is often required in order to apply and/or calibrate the conversion models. However, depending on the tracer involved, the depth distribution, and thus the sampling resolution required to define it, differs. For example, a depth resolution of 1 cm is often adequate when using 137 Cs. However, fallout 210 Pb and 7 Be commonly has very strong surface maxima that decrease exponentially with depth, and fine depth increments are required at or close to the soil surface. Consequently, different depth incremental sampling methods are required when using different fallout radionuclides. Geomorphic investigations also frequently require determination of the depth-distribution of fallout nuclides on slopes and depositional sites as well as their total inventories

  12. Assessing total and volatile solids in municipal solid waste samples.

    Science.gov (United States)

    Peces, M; Astals, S; Mata-Alvarez, J

    2014-01-01

    Municipal solid waste is broadly generated in everyday activities and its treatment is a global challenge. Total solids (TS) and volatile solids (VS) are typical control parameters measured in biological treatments. In this study, the TS and VS were determined using the standard methods, as well as introducing some variants: (i) the drying temperature for the TS assays was 105°C, 70°C and 50°C and (ii) the VS were determined using different heating ramps from room tempature to 550°C. TS could be determined at either 105°C or 70°C, but oven residence time was tripled at 70°C, increasing from 48 to 144 h. The VS could be determined by smouldering the sample (where the sample is burnt without a flame), which avoids the release of fumes and odours in the laboratory. However, smouldering can generate undesired pyrolysis products as a consequence of carbonization, which leads to VS being underestimated. Carbonization can be avoided using slow heating ramps to prevent the oxygen limitation. Furthermore, crushing the sample cores decreased the time to reach constant weight and decreased the potential to underestimate VS.

  13. Total Arsenic, Cadmium, and Lead Determination in Brazilian Rice Samples Using ICP-MS

    OpenAIRE

    Mataveli, Lidiane Raquel Verola; Buzzo, Márcia Liane; Arauz, Luciana Juncioni de; Carvalho, Maria de Fátima Henriques; Arakaki, Edna Emy Kumagai; Matsuzaki, Richard; Tiglea, Paulo

    2016-01-01

    This study is aimed at investigating a suitable method for rice sample preparation as well as validating and applying the method for monitoring the concentration of total arsenic, cadmium, and lead in rice by using Inductively Coupled Plasma Mass Spectrometry (ICP-MS). Various rice sample preparation procedures were evaluated. The analytical method was validated by measuring several parameters including limit of detection (LOD), limit of quantification (LOQ), linearity, relative bias, and rep...

  14. Porous Silicon Antibody Microarrays for Quantitative Analysis: Measurement of Free and Total PSA in Clinical Plasma Samples

    Science.gov (United States)

    Tojo, Axel; Malm, Johan; Marko-Varga, György; Lilja, Hans; Laurell, Thomas

    2014-01-01

    The antibody microarrays have become widespread, but their use for quantitative analyses in clinical samples has not yet been established. We investigated an immunoassay based on nanoporous silicon antibody microarrays for quantification of total prostate-specific-antigen (PSA) in 80 clinical plasma samples, and provide quantitative data from a duplex microarray assay that simultaneously quantifies free and total PSA in plasma. To further develop the assay the porous silicon chips was placed into a standard 96-well microtiter plate for higher throughput analysis. The samples analyzed by this quantitative microarray were 80 plasma samples obtained from men undergoing clinical PSA testing (dynamic range: 0.14-44ng/ml, LOD: 0.14ng/ml). The second dataset, measuring free PSA (dynamic range: 0.40-74.9ng/ml, LOD: 0.47ng/ml) and total PSA (dynamic range: 0.87-295ng/ml, LOD: 0.76ng/ml), was also obtained from the clinical routine. The reference for the quantification was a commercially available assay, the ProStatus PSA Free/Total DELFIA. In an analysis of 80 plasma samples the microarray platform performs well across the range of total PSA levels. This assay might have the potential to substitute for the large-scale microtiter plate format in diagnostic applications. The duplex assay paves the way for a future quantitative multiplex assay, which analyses several prostate cancer biomarkers simultaneously. PMID:22921878

  15. Determination of total chromium in tanned leather samples used in car industry.

    Science.gov (United States)

    Zeiner, Michaela; Rezić, Iva; Ujević, Darko; Steffan, Ilse

    2011-03-01

    Despite the high competition of synthetic fibers leather is nowadays still widely used for many applications. In order to ensure a sufficient stability of the skin matrix against many factors, such as microbial degradation, heat and sweat, a tanning process is indispensable. Using chromium (III) for this purpose offers a multitude of advantages, thus this way of tanning is widely applied. During the use of chromium tanned leather as clothing material as well as for decoration/covering purposes, chromium is extracted from the leather and may then cause nocuous effects to human skin, e.g. allergic reactions. Thus the knowledge of the total chromium content of leather samples expected to come into prolonged touch with human skin is very important. In car industry leather is used as cover for seats, steering wheel and gearshift lever The chromium contents often chromium tanned leather samples used in car industry were determined. First all samples were dried at 65 degrees C overnight and then cut in small pieces using a ceramic knife, weighed and analyzed by inductively coupled plasma--optical emission spectrometry (ICP-OES) after acidic microwave assisted digestion. The total chromium amounts found were in the range from 19 mg/g up to 32 mg/g. The extraction yield of chromium from leather samples in sweat is approximately 2-7%. Thus especially during long journeys in summer chromium can be extracted in amounts which may cause nocuous effects for example on the palm of the hands or on the back.

  16. Quality control on the accuracy of the total Beta activity index in different sample matrices water; Control de calidad en la precision del indice de actividad beta total en diferentes matrices de muestras de aguas

    Energy Technology Data Exchange (ETDEWEB)

    Pujol, L.; Pablo, M. A. de; Payeras, J.

    2013-07-01

    The standard ISO/IEC 17025:2005 of general requirements for the technical competence of testing and calibration laboratories, provides that a laboratory shall have quality control procedures for monitoring the validity of tests and calibrations ago. In this paper, the experience of Isotopic Applications Laboratory (CEDEX) in controlling the accuracy rate of total beta activity in samples of drinking water, inland waters and marine waters is presented. (Author)

  17. Fiscal Year 2001 Tank Characterization Technical Sampling Basis and Waste Information Requirements Document

    International Nuclear Information System (INIS)

    ADAMS, M.R.

    2000-01-01

    The Fiscal Year 2001 Tank Characterization Technical Sampling Basis and Waste Information Requirements Document (TSB-WIRD) has the following purposes: (1) To identify and integrate sampling and analysis needs for fiscal year (FY) 2001 and beyond. (2) To describe the overall drivers that require characterization information and to document their source. (3) To describe the process for identifying, prioritizing, and weighting issues that require characterization information to resolve. (4) To define the method for determining sampling priorities and to present the sampling priorities on a tank-by-tank basis. (5) To define how the characterization program is going to satisfy the drivers, close issues, and report progress. (6)To describe deliverables and acceptance criteria for characterization deliverables

  18. Multielement analysis of environmental samples by total-reflection X-ray fluorescence sprectrometry, neutron activation analysis and inductively coupled plasma optical emission spectroscopy

    International Nuclear Information System (INIS)

    Michaelis, W.

    1986-01-01

    In environmental research and protection trace elements have to be determined over a wide range of atomic number, down to very low concentrations, and in quite different matrices. This challenge requires the availability of complementary analytical methods characterized by a high detection power and few sources of systematic errors. Besides, the capacity of multielement detection is often desired since it facilitates the talking of many problems in which numerous trace elements are of direct concern. Total-reflection X-ray fluorescence, neutron activation analysis and inductively coupled plasma optical emission spectroscopy, in principle fulfill these requirements quite well. However, each method has its domain, and the application to certain sample species may be less promising. Under this aspect, the paper summarizes some recent developments and investigations, including intercomparisons as far as possible. Various matrices are considered : rainwater and airborne particulates, soil samples, river sediments and suspended particulate matter, river water filtrates, ozean water, and organic matrices. Capabilities and limitations are discussed. Sample preparation techniques are described if they are new or essential for achieving the results given. (orig.) [de

  19. Application of Total Quality Management (TQM) Requirements in Risk Management in Construction Projects in Iraq

    OpenAIRE

    Entisar K. Al-Geelawee; Anfal Nadhel Mohammed

    2016-01-01

    Total quality management considers one of the modern scientific entrances which practiced by productivity service organizations alike to provide appropriate quality required outputs according to the needs and desires of customers manage , enable the organization seeking to continue and grow in light of the increasing competition from the satisfy and provide the appropriate total quality management requirements whenever led to face risks that they may have in a manner in which they can be a...

  20. 40 CFR 80.1348 - What gasoline sample retention requirements apply to refiners and importers?

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 16 2010-07-01 2010-07-01 false What gasoline sample retention... PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) REGULATION OF FUELS AND FUEL ADDITIVES Gasoline Benzene Sampling, Testing and Retention Requirements § 80.1348 What gasoline sample retention requirements...

  1. Comparison of conventional and total reflection excitation geometry for fluorescence X-ray absorption spectroscopy on droplet samples

    International Nuclear Information System (INIS)

    Falkenberg, G.; Pepponi, G.; Streli, C.; Wobrauschek, P.

    2003-01-01

    X-ray absorption fine structure (XAFS) experiments in fluorescence mode have been performed in total reflection excitation geometry and conventional 45 deg. /45 deg. excitation/detection geometry for comparison. The experimental results have shown that XAFS measurements are feasible under normal total reflection X-ray fluorescence (TXRF) conditions, i.e. on droplet samples, with excitation in grazing incidence and using a TXRF experimental chamber. The application of the total reflection excitation geometry for XAFS measurements increases the sensitivity compared to the conventional geometry leading to lower accessible concentration ranges. However, XAFS under total reflection excitation condition fails for highly concentrated samples because of the self-absorption effect

  2. 21 CFR 111.465 - What requirements apply to holding reserve samples of dietary supplements?

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 2 2010-04-01 2010-04-01 false What requirements apply to holding reserve samples... Distributing § 111.465 What requirements apply to holding reserve samples of dietary supplements? (a) You must hold reserve samples of dietary supplements in a manner that protects against contamination and...

  3. Determination of total mercury and methylmercury in biological samples by photochemical vapor generation

    Energy Technology Data Exchange (ETDEWEB)

    Vieira, Mariana A.; Ribeiro, Anderson S.; Curtius, Adilson J. [Universidade Federal de Santa Catarina, Departamento de Quimica, Florianopolis, SC (Brazil); Sturgeon, Ralph E. [National Research Council Canada, Institute for National Measurement Standards, Ottawa, ON (Canada)

    2007-06-15

    Cold vapor atomic absorption spectrometry (CV-AAS) based on photochemical reduction by exposure to UV radiation is described for the determination of methylmercury and total mercury in biological samples. Two approaches were investigated: (a) tissues were digested in either formic acid or tetramethylammonium hydroxide (TMAH), and total mercury was determined following reduction of both species by exposure of the solution to UV irradiation; (b) tissues were solubilized in TMAH, diluted to a final concentration of 0.125% m/v TMAH by addition of 10% v/v acetic acid and CH{sub 3}Hg{sup +} was selectively quantitated, or the initial digests were diluted to 0.125% m/v TMAH by addition of deionized water, adjusted to pH 0.3 by addition of HCl and CH{sub 3}Hg{sup +} was selectively quantitated. For each case, the optimum conditions for photochemical vapor generation (photo-CVG) were investigated. The photochemical reduction efficiency was estimated to be {proportional_to}95% by comparing the response with traditional SnCl{sub 2} chemical reduction. The method was validated by analysis of several biological Certified Reference Materials, DORM-1, DORM-2, DOLT-2 and DOLT-3, using calibration against aqueous solutions of Hg{sup 2+}; results showed good agreement with the certified values for total and methylmercury in all cases. Limits of detection of 6 ng/g for total mercury using formic acid, 8 ng/g for total mercury and 10 ng/g for methylmercury using TMAH were obtained. The proposed methodology is sensitive, simple and inexpensive, and promotes ''green'' chemistry. The potential for application to other sample types and analytes is evident. (orig.)

  4. Study on the relation between uranium content and total phosphorus in some sudanese phosphate ore samples

    International Nuclear Information System (INIS)

    Eltayeb, M. A. H.; Mohammed, A. A.

    2003-01-01

    In the present work uranium content and total phosphorus were determined in 30 phosphate ore samples collected from Kurun and Uro areas in Nuba Mountains in Sudan. Spectrophotometry technique was used for this purpose. Uranium analysis is based on the use of nitrogen (V) acid for leaching the rock, and treatment with ammonium carbonate solution, whereby uranium (Vi) is kept in solution as its carbonate complex. The ion exchange technique was used for the recovery of uranium. Uranium was eluted from the resin with 1 M hydrochloric acid. In the elute, uranium was determined spectrophotometrically by measurement of absorbance of the yellow uranium (Vi)-8-hydroxyquinolate complex at λ 400 nm. The total phosphorus was measured as (P 2 O 5 %) by treatment of the total liquor with ammonium molybdate solution. The absorbance of the blue complex was measured at λ 880 nm. The results show that a limited relation is existed between uranium content and total phosphorus in phosphate samples from kurun area, which contain 58.8 ppm uranium in average, where there are no relation is existed in phosphate samples from uro area, which contain 200 ppm uranium in average. (Author)

  5. High-throughput analysis using non-depletive SPME: challenges and applications to the determination of free and total concentrations in small sample volumes.

    Science.gov (United States)

    Boyacı, Ezel; Bojko, Barbara; Reyes-Garcés, Nathaly; Poole, Justen J; Gómez-Ríos, Germán Augusto; Teixeira, Alexandre; Nicol, Beate; Pawliszyn, Janusz

    2018-01-18

    In vitro high-throughput non-depletive quantitation of chemicals in biofluids is of growing interest in many areas. Some of the challenges facing researchers include the limited volume of biofluids, rapid and high-throughput sampling requirements, and the lack of reliable methods. Coupled to the above, growing interest in the monitoring of kinetics and dynamics of miniaturized biosystems has spurred the demand for development of novel and revolutionary methodologies for analysis of biofluids. The applicability of solid-phase microextraction (SPME) is investigated as a potential technology to fulfill the aforementioned requirements. As analytes with sufficient diversity in their physicochemical features, nicotine, N,N-Diethyl-meta-toluamide, and diclofenac were selected as test compounds for the study. The objective was to develop methodologies that would allow repeated non-depletive sampling from 96-well plates, using 100 µL of sample. Initially, thin film-SPME was investigated. Results revealed substantial depletion and consequent disruption in the system. Therefore, new ultra-thin coated fibers were developed. The applicability of this device to the described sampling scenario was tested by determining the protein binding of the analytes. Results showed good agreement with rapid equilibrium dialysis. The presented method allows high-throughput analysis using small volumes, enabling fast reliable free and total concentration determinations without disruption of system equilibrium.

  6. Study on the relation between uranium content and total phosphorus in some sudanese phosphate ore samples

    International Nuclear Information System (INIS)

    Mohammed, A.A.; Eltayeb, M.A.H.

    2003-01-01

    In the present work uranium content and total phosphorous were determined in 30 phosphate ore samples collected from Kurun and Uro areas in Nuba mountains in sudan. Spectrophotometry technique was used for this purpose. Uranium analysis is based on the use of nitrogen (V) acid for leaching the rock, and treatment with ammonium carbonate solution, whereby uranium (VI) is kept in solution as its carbonate complex. The ion-exchange technique was used for the recovery of uranium. Uranium was eluted from the resin with 1 M hydrochloric acid. In the elute, uranium was determined spectrophotometrically by measurement of the absorbance of the yellow uranium (VI) - 8- hydroxyquinolate complex at λ 400 nm. The total phosphorus was measured as (P 2 O 5 %) by treatment of the leach liquor with ammonium molybdate solution. The absorbance of the blue complex was measured at λ 880 nm. The results show that a limited relation is existed between uranium content and total phosphorus in phosphate samples from Kurun area, which contain 58.8 ppm uranium in average, where there are no relation is existed in phosphate samples samples from Uro area, which contain 200 ppm uranium in average

  7. Assessing total nitrogen in surface-water samples--precision and bias of analytical and computational methods

    Science.gov (United States)

    Rus, David L.; Patton, Charles J.; Mueller, David K.; Crawford, Charles G.

    2013-01-01

    concentrations up to 750 mg/L (median of -4.4 percent). This lent support to the laboratory-experiment finding that some particulate nitrogen is sequestered during the digestion process, and demonstrated that negative TN-A bias was present in samples with very low suspended-sediment concentrations. At sediment concentrations above 750 mg/L, the negative TN-A bias became more likely and larger (median of -13.2 percent), suggesting a secondary mechanism of bias, such as reagent limitation. From a geospatial perspective, trends in TN-A bias were not explained by selected basin characteristics. Though variable, TN-K bias generally was positive in the synoptic-field study (median of 3.1 percent), probably as a result of the reduction of nitrate. Three alternative approaches for assessing TN in surface water were evaluated for their impacts on existing and future sampling programs. Replacing TN-A with TN-C would remove the bias from subsequent data, but this approach also would introduce discontinuity in historical records. Replacing TN-K with TN-C would lead to the removal of positive bias in TN-K in the presence of elevated nitrate. However, in addition to the issues that may arise from a discontinuity in the data record, this approach may not be applicable to regulatory programs that require the use of total Kjeldahl nitrogen for stream assessment. By adding TN-C to existing TN-A or TN-K analyses, historical-data continuity would be preserved and the transitional period could be used to minimize the impact of bias on data analyses. This approach, however, imposes the greatest burdens on field operations and in terms of analytical costs. The variation in these impacts on different sampling programs will challenge U.S. Geological Survey scientists attempting to establish uniform standards for TN sample collection and analytical determinations.

  8. Determination of total mercury for marine environmental monitoring studies by solid sampling continuum source high resolution atomic absorption spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Mandjukov, Petko; Orani, Anna Maria; Han, Eunmi; Vassileva, Emilia, E-mail: e.vasileva-veleva@iaea.org

    2015-01-01

    The most critical step in almost all commonly used analytical procedures for Hg determination is the sample preparation due to its extreme volatility. One of the possible solutions of this problem is the application of methods for direct analysis of solid samples. The possibilities for solid sampling high resolution continuum source atomic absorption spectrometry (HR CS AAS) determination of total mercury in various marine environmental samples e.g. sediments and biota are object of the present study. The instrumental parameters were optimized in order to obtain reproducible and interference free analytical signal. A calibration technique based on the use of solid standard certified reference materials similar to the nature of the analyzed sample was developed and applied to various CRMs and real samples. This technique allows simple and reliable evaluation of the uncertainty of the result and the metrological characteristics of the method. A validation approach in line with the requirements of ISO 17025 standard and Eurachem guidelines was followed. With this in mind, selectivity, working range (0.06 to 25 ng for biota and 0.025 to 4 ng for sediment samples, expressed as total Hg) linearity (confirmed by Student's t-test), bias (1.6–4.3%), repeatability (4–9%), reproducibility (9–11%), and absolute limit of detection (0.025 ng for sediment, 0.096 ng for marine biota) were systematically assessed using solid CRMs. The relative expanded uncertainty was estimated at 15% for sediment sample and 8.5% for marine biota sample (k = 2). Demonstration of traceability of measurement results is also presented. The potential of the proposed analytical procedure, based on solid sampling HR CS AAS technique was demonstrated by direct analysis of sea sediments form the Caribbean region and various CRMs. Overall, the use of solid sampling HR CS AAS permits obtaining significant advantages for the determination of this complex analyte in marine samples, such as

  9. [Hygienic evaluation of the total mutagenic activity of snow samples from Magnitogorsk].

    Science.gov (United States)

    Legostaeva, T B; Ingel', F I; Antipanova, N A; Iurchenko, V V; Iuretseva, N A; Kotliar, N N

    2010-01-01

    The paper gives the results of 4-year monitoring of the total mutagenic activity of snow samples from different Magnitogork areas in a test for induction of dominant lethal mutations (DLM) in the gametes of Drosophila melanogaster. An association was first found between the rate of DLM and the content of some chemical compounds in the ambient air and snow samples; moreover all the substances present in the samples, which had found genotoxic effects, showed a positive correlation with the rate of DLM. Furthermore, direct correlations were first established between the rate of DLM and the air pollution index and morbidity rates in 5-7-year-old children residing in the areas under study. The findings allow the test for induction of dominant lethal mutations (DLM) in the gametes of Drosophila melanogaster to be recommended due to its unique informative and prognostic value for monitoring ambient air pollution and for extensive use in the risk assessment system.

  10. Mars Sample Return: Mars Ascent Vehicle Mission and Technology Requirements

    Science.gov (United States)

    Bowles, Jeffrey V.; Huynh, Loc C.; Hawke, Veronica M.; Jiang, Xun J.

    2013-01-01

    A Mars Sample Return mission is the highest priority science mission for the next decade recommended by the recent Decadal Survey of Planetary Science, the key community input process that guides NASAs science missions. A feasibility study was conducted of a potentially simple and low cost approach to Mars Sample Return mission enabled by the use of developing commercial capabilities. Previous studies of MSR have shown that landing an all up sample return mission with a high mass capacity lander is a cost effective approach. The approach proposed is the use of an emerging commercially available capsule to land the launch vehicle system that would return samples to Earth. This paper describes the mission and technology requirements impact on the launch vehicle system design, referred to as the Mars Ascent Vehicle (MAV).

  11. Determination of total gas in lithium tritide-deuteride compounds

    International Nuclear Information System (INIS)

    Smith, M.E.; Koski, N.L.; Waterbury, G.R.

    1979-04-01

    Lithium tritide--deuteride samples are enclosed in a copper foil and decomposed by heating to 850 0 C in a copper reaction tube in vacuum. The temperature and pressure of the evolved gas, collected in a measured volume using a Toepler pump, are measured to determine the total moles of gas released from the sample. The gas is transferred to a removable sample bulb and, if required, analyzed for gaseous constituents by mass spectrometry. Based on 14 total gas determinations for a lithium deuteride sample, the calculated relative standard deviation was 1.0% and the estimated bias was <2.5%

  12. Analysis of low Z elements in various environmental samples with total reflection X-ray fluorescence (TXRF) spectrometry

    International Nuclear Information System (INIS)

    Hoefler, H.; Streli, C.; Wobrauschek, P.; Ovari, M.; Zaray, Gy.

    2006-01-01

    Recently there is a growing interest in low Z elements such as carbon, oxygen up to sulphur and phosphorus in biological specimen. Total reflection X-ray fluorescence (TXRF) spectrometry is a suitable technique demanding only very small amounts of sample. On the other side, the detection of low Z elements is a critical point of this analytical technique. Besides other effects, self absorption may occur in the samples, because of the low energy of the fluorescence radiation. The calibration curves might be not linear any longer. To investigate this issue water samples and samples from human cerebrospinal fluid were used to examine absorption effects. The linearity of calibration curves in dependence of sample mass was investigated to verify the validity of the thin film approximation. The special requirements to the experimental setup for low Z energy dispersive fluorescence analysis were met by using the Atominstitute's TXRF vacuum chamber. This spectrometer is equipped with a Cr-anode X-ray tube, a multilayer monochromator and a SiLi detector with 30 mm 2 active area and with an ultrathin entrance window. Other object on this study are biofilms, living on all subaqueous surfaces, consisting of bacteria, algae and fungi embedded in their extracellular polymeric substances (EPS). Many trace elements from the water are bound in the biofilm. Thus, the biofilm is a useful indicator for polluting elements. For biomonitoring purposes not only the polluting elements but also the formation and growth rate of the biofilm are important. Biofilms were directly grown on TXRF reflectors. Their major elements and C-masses correlated to the cultivation time were investigated. These measured masses were related to the area seen by the detector, which was experimentally determined. Homogeneity of the biofilms was checked by measuring various sample positions on the reflectors

  13. Analysis of low Z elements in various environmental samples with total reflection X-ray fluorescence (TXRF) spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Hoefler, H. [Atominstitut of the Austrian Universities, TU-Wien, A-1020 Vienna (Austria); Streli, C. [Atominstitut of the Austrian Universities, TU-Wien, A-1020 Vienna (Austria)]. E-mail: streli@ati.ac.at; Wobrauschek, P. [Atominstitut of the Austrian Universities, TU-Wien, A-1020 Vienna (Austria); Ovari, M. [Eoetvoes University, Institute of Chemistry, H-1117, Budapest, Pazmany P. stny 1/a. (Hungary); Zaray, Gy. [Eoetvoes University, Institute of Chemistry, H-1117, Budapest, Pazmany P. stny 1/a. (Hungary)

    2006-11-15

    Recently there is a growing interest in low Z elements such as carbon, oxygen up to sulphur and phosphorus in biological specimen. Total reflection X-ray fluorescence (TXRF) spectrometry is a suitable technique demanding only very small amounts of sample. On the other side, the detection of low Z elements is a critical point of this analytical technique. Besides other effects, self absorption may occur in the samples, because of the low energy of the fluorescence radiation. The calibration curves might be not linear any longer. To investigate this issue water samples and samples from human cerebrospinal fluid were used to examine absorption effects. The linearity of calibration curves in dependence of sample mass was investigated to verify the validity of the thin film approximation. The special requirements to the experimental setup for low Z energy dispersive fluorescence analysis were met by using the Atominstitute's TXRF vacuum chamber. This spectrometer is equipped with a Cr-anode X-ray tube, a multilayer monochromator and a SiLi detector with 30 mm{sup 2} active area and with an ultrathin entrance window. Other object on this study are biofilms, living on all subaqueous surfaces, consisting of bacteria, algae and fungi embedded in their extracellular polymeric substances (EPS). Many trace elements from the water are bound in the biofilm. Thus, the biofilm is a useful indicator for polluting elements. For biomonitoring purposes not only the polluting elements but also the formation and growth rate of the biofilm are important. Biofilms were directly grown on TXRF reflectors. Their major elements and C-masses correlated to the cultivation time were investigated. These measured masses were related to the area seen by the detector, which was experimentally determined. Homogeneity of the biofilms was checked by measuring various sample positions on the reflectors.

  14. Forensic application of total reflection X-ray fluorescence spectrometry for elemental characterization of ink samples

    International Nuclear Information System (INIS)

    Dhara, Sangita; Misra, N.L.; Maind, S.D.; Kumar, Sanjukta A.; Chattopadhyay, N.; Aggarwal, S.K.

    2010-01-01

    The possibility of applying Total Reflection X-ray Fluorescence for qualitative and quantitative differentiation of documents printed with rare earth tagged and untagged inks has been explored in this paper. For qualitative differentiation, a very small amount of ink was loosened from the printed documents by smoothly rubbing with a new clean blade without destroying the manuscript. 50 μL of Milli-Q water was put on this loose powder, on the manuscript, and was agitated by sucking and releasing the suspension two to three times with the help of a micropipette. The resultant dispersion was deposited on quartz sample support for Total Reflection X-ray Fluorescence measurements. The Total Reflection X-ray Fluorescence spectrum of tagged and untagged inks could be clearly differentiated. In order to see the applicability of Total Reflection X-ray Fluorescence for quantitative determinations of rare earths and also to countercheck such determinations in ink samples, the amounts of rare earth in painted papers with single rare earth tagged inks were determined by digesting the painted paper in HNO 3 /HClO 4 , mixing this solution with the internal standard and recording their Total Reflection X-ray Fluorescence spectra after calibration of the instrument. The results thus obtained were compared with those obtained by Inductively Coupled Plasma Mass Spectrometry and were found in good agreement. The average precision of the Total Reflection X-ray Fluorescence determinations was 5.5% (1σ) and the average deviation of Total Reflection X-ray Fluorescence determined values with that of Inductively Coupled Plasma Mass Spectrometry was 7.3%. These studies have shown that Total Reflection X-ray Fluorescence offers a promising and potential application in forensic work of this nature.

  15. Forensic application of total reflection X-ray fluorescence spectrometry for elemental characterization of ink samples

    Energy Technology Data Exchange (ETDEWEB)

    Dhara, Sangita [Fuel Chemistry Division, Bhabha Atomic Research Centre, Mumbai 400 085 (India); Misra, N.L., E-mail: nlmisra@barc.gov.i [Fuel Chemistry Division, Bhabha Atomic Research Centre, Mumbai 400 085 (India); Maind, S.D. [NAA Unit of Central Forensic Science Laboratory Hyderabad at Analytical Chemistry Division, Bhabha Atomic Research Centre, Mumbai 400 085 (India); Kumar, Sanjukta A. [Analytical Chemistry Division, Bhabha Atomic Research Centre, Mumbai 400 085 (India); Chattopadhyay, N. [NAA Unit of Central Forensic Science Laboratory Hyderabad at Analytical Chemistry Division, Bhabha Atomic Research Centre, Mumbai 400 085 (India); Aggarwal, S.K. [Fuel Chemistry Division, Bhabha Atomic Research Centre, Mumbai 400 085 (India)

    2010-02-15

    The possibility of applying Total Reflection X-ray Fluorescence for qualitative and quantitative differentiation of documents printed with rare earth tagged and untagged inks has been explored in this paper. For qualitative differentiation, a very small amount of ink was loosened from the printed documents by smoothly rubbing with a new clean blade without destroying the manuscript. 50 muL of Milli-Q water was put on this loose powder, on the manuscript, and was agitated by sucking and releasing the suspension two to three times with the help of a micropipette. The resultant dispersion was deposited on quartz sample support for Total Reflection X-ray Fluorescence measurements. The Total Reflection X-ray Fluorescence spectrum of tagged and untagged inks could be clearly differentiated. In order to see the applicability of Total Reflection X-ray Fluorescence for quantitative determinations of rare earths and also to countercheck such determinations in ink samples, the amounts of rare earth in painted papers with single rare earth tagged inks were determined by digesting the painted paper in HNO{sub 3}/HClO{sub 4}, mixing this solution with the internal standard and recording their Total Reflection X-ray Fluorescence spectra after calibration of the instrument. The results thus obtained were compared with those obtained by Inductively Coupled Plasma Mass Spectrometry and were found in good agreement. The average precision of the Total Reflection X-ray Fluorescence determinations was 5.5% (1sigma) and the average deviation of Total Reflection X-ray Fluorescence determined values with that of Inductively Coupled Plasma Mass Spectrometry was 7.3%. These studies have shown that Total Reflection X-ray Fluorescence offers a promising and potential application in forensic work of this nature.

  16. First Total Reflection X-Ray Fluorescence round-robin test of water samples: Preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Borgese, Laura; Bilo, Fabjola [Chemistry for Technologies Laboratory, University of Brescia, Brescia (Italy); Tsuji, Kouichi [Graduate School of Engineering, Osaka City University, Osaka (Japan); Fernández-Ruiz, Ramón [Servicio Interdepartamental de Investigación (SIdI), Laboratorio de TXRF, Universidad Autónoma de Madrid, Madrid (Spain); Margui, Eva [Department of Chemistry, University of Girona, Girona (Spain); Streli, Christina [TU Wien, Atominstitut,Radiation Physics, Vienna (Austria); Pepponi, Giancarlo [Fondazione Bruno Kessler, Povo, Trento (Italy); Stosnach, Hagen [Bruker Nano GmbH, Berlin (Germany); Yamada, Takashi [Rigaku Corporation, Takatsuki, Osaka (Japan); Vandenabeele, Peter [Department of Archaeology, Ghent University, Ghent (Belgium); Maina, David M.; Gatari, Michael [Institute of Nuclear Science and Technology, University of Nairobi, Nairobi (Kenya); Shepherd, Keith D.; Towett, Erick K. [World Agroforestry Centre (ICRAF), Nairobi (Kenya); Bennun, Leonardo [Laboratorio de Física Aplicada, Departamento de Física, Universidad de Concepción (Chile); Custo, Graciela; Vasquez, Cristina [Gerencia Química, Laboratorio B025, Centro Atómico Constituyentes, San Martín (Argentina); Depero, Laura E., E-mail: laura.depero@unibs.it [Chemistry for Technologies Laboratory, University of Brescia, Brescia (Italy)

    2014-11-01

    Total Reflection X-Ray Fluorescence (TXRF) is a mature technique to evaluate quantitatively the elemental composition of liquid samples deposited on clean and well polished reflectors. In this paper the results of the first worldwide TXRF round-robin test of water samples, involving 18 laboratories in 10 countries are presented and discussed. The test was performed within the framework of the VAMAS project, interlaboratory comparison of TXRF spectroscopy for environmental analysis, whose aim is to develop guidelines and a standard methodology for biological and environmental analysis by means of the TXRF analytical technique. - Highlights: • The discussion of the first worldwide TXRF round-robin test of water samples (18 laboratories of 10 countries) is reported. • Drinking, waste, and desalinated water samples were tested. • Data dispersion sources were identified: sample concentration, preparation, fitting procedure, and quantification. • The protocol for TXRF analysis of drinking water is proposed.

  17. Evaluation of Respondent-Driven Sampling

    Science.gov (United States)

    McCreesh, Nicky; Frost, Simon; Seeley, Janet; Katongole, Joseph; Tarsh, Matilda Ndagire; Ndunguse, Richard; Jichi, Fatima; Lunel, Natasha L; Maher, Dermot; Johnston, Lisa G; Sonnenberg, Pam; Copas, Andrew J; Hayes, Richard J; White, Richard G

    2012-01-01

    Background Respondent-driven sampling is a novel variant of link-tracing sampling for estimating the characteristics of hard-to-reach groups, such as HIV prevalence in sex-workers. Despite its use by leading health organizations, the performance of this method in realistic situations is still largely unknown. We evaluated respondent-driven sampling by comparing estimates from a respondent-driven sampling survey with total-population data. Methods Total-population data on age, tribe, religion, socioeconomic status, sexual activity and HIV status were available on a population of 2402 male household-heads from an open cohort in rural Uganda. A respondent-driven sampling (RDS) survey was carried out in this population, employing current methods of sampling (RDS sample) and statistical inference (RDS estimates). Analyses were carried out for the full RDS sample and then repeated for the first 250 recruits (small sample). Results We recruited 927 household-heads. Full and small RDS samples were largely representative of the total population, but both samples under-represented men who were younger, of higher socioeconomic status, and with unknown sexual activity and HIV status. Respondent-driven-sampling statistical-inference methods failed to reduce these biases. Only 31%-37% (depending on method and sample size) of RDS estimates were closer to the true population proportions than the RDS sample proportions. Only 50%-74% of respondent-driven-sampling bootstrap 95% confidence intervals included the population proportion. Conclusions Respondent-driven sampling produced a generally representative sample of this well-connected non-hidden population. However, current respondent-driven-sampling inference methods failed to reduce bias when it occurred. Whether the data required to remove bias and measure precision can be collected in a respondent-driven sampling survey is unresolved. Respondent-driven sampling should be regarded as a (potentially superior) form of convenience-sampling

  18. Evaluation of respondent-driven sampling.

    Science.gov (United States)

    McCreesh, Nicky; Frost, Simon D W; Seeley, Janet; Katongole, Joseph; Tarsh, Matilda N; Ndunguse, Richard; Jichi, Fatima; Lunel, Natasha L; Maher, Dermot; Johnston, Lisa G; Sonnenberg, Pam; Copas, Andrew J; Hayes, Richard J; White, Richard G

    2012-01-01

    Respondent-driven sampling is a novel variant of link-tracing sampling for estimating the characteristics of hard-to-reach groups, such as HIV prevalence in sex workers. Despite its use by leading health organizations, the performance of this method in realistic situations is still largely unknown. We evaluated respondent-driven sampling by comparing estimates from a respondent-driven sampling survey with total population data. Total population data on age, tribe, religion, socioeconomic status, sexual activity, and HIV status were available on a population of 2402 male household heads from an open cohort in rural Uganda. A respondent-driven sampling (RDS) survey was carried out in this population, using current methods of sampling (RDS sample) and statistical inference (RDS estimates). Analyses were carried out for the full RDS sample and then repeated for the first 250 recruits (small sample). We recruited 927 household heads. Full and small RDS samples were largely representative of the total population, but both samples underrepresented men who were younger, of higher socioeconomic status, and with unknown sexual activity and HIV status. Respondent-driven sampling statistical inference methods failed to reduce these biases. Only 31%-37% (depending on method and sample size) of RDS estimates were closer to the true population proportions than the RDS sample proportions. Only 50%-74% of respondent-driven sampling bootstrap 95% confidence intervals included the population proportion. Respondent-driven sampling produced a generally representative sample of this well-connected nonhidden population. However, current respondent-driven sampling inference methods failed to reduce bias when it occurred. Whether the data required to remove bias and measure precision can be collected in a respondent-driven sampling survey is unresolved. Respondent-driven sampling should be regarded as a (potentially superior) form of convenience sampling method, and caution is required

  19. Application of hydrocyanic acid vapor generation via focused microwave radiation to the preparation of industrial effluent samples prior to free and total cyanide determinations by spectrophotometric flow injection analysis.

    Science.gov (United States)

    Quaresma, Maria Cristina Baptista; de Carvalho, Maria de Fátima Batista; Meirelles, Francis Assis; Santiago, Vânia Maria Junqueira; Santelli, Ricardo Erthal

    2007-02-01

    A sample preparation procedure for the quantitative determination of free and total cyanides in industrial effluents has been developed that involves hydrocyanic acid vapor generation via focused microwave radiation. Hydrocyanic acid vapor was generated from free cyanides using only 5 min of irradiation time (90 W power) and a purge time of 5 min. The HCN generated was absorbed into an accepting NaOH solution using very simple glassware apparatus that was appropriate for the microwave oven cavity. After that, the cyanide concentration was determined within 90 s using a well-known spectrophotometric flow injection analysis system. Total cyanide analysis required 15 min irradiation time (90 W power), as well as chemical conditions such as the presence of EDTA-acetate buffer solution or ascorbic acid, depending on the effluent to be analyzed (petroleum refinery or electroplating effluents, respectively). The detection limit was 0.018 mg CN l(-1) (quantification limit of 0.05 mg CN l(-1)), and the measured RSD was better than 8% for ten independent analyses of effluent samples (1.4 mg l(-1) cyanide). The accuracy of the procedure was assessed via analyte spiking (with free and complex cyanides) and by performing an independent sample analysis based on the standard methodology recommended by the APHA for comparison. The sample preparation procedure takes only 10 min for free and 20 min for total cyanide, making this procedure much faster than traditional methodologies (conventional heating and distillation), which are time-consuming (they require at least 1 h). Samples from oil (sour and stripping tower bottom waters) and electroplating effluents were analyzed successfully.

  20. An analysis of cross-sectional variations in total household energy requirements in India using micro survey data

    International Nuclear Information System (INIS)

    Pachauri, Shonali

    2004-01-01

    Using micro level household survey data from India, we analyse the variation in the pattern and quantum of household energy requirements, both direct and indirect, and the factors causing such variation. An econometric analysis using household survey data from India for the year 1993-1994 reveals that household socio-economic, demographic, geographic, family and dwelling attributes influence the total household energy requirements. There are also large variations in the pattern of energy requirements across households belonging to different expenditure classes. Results from the econometric estimation show that total household expenditure or income level is the most important explanatory variable causing variation in energy requirements across households. In addition, the size of the household dwelling and the age of the head of the household are related to higher household energy requirements. In contrast, the number of members in the household and literacy of the head are associated with lower household energy requirements

  1. An analysis of cross-sectional variations in total household energy requirements in India using micro survey data

    Energy Technology Data Exchange (ETDEWEB)

    Pachauri, Shonali E-mail: shonali.pachauri@cepe.mavt.ethz.ch

    2004-10-01

    Using micro level household survey data from India, we analyse the variation in the pattern and quantum of household energy requirements, both direct and indirect, and the factors causing such variation. An econometric analysis using household survey data from India for the year 1993-1994 reveals that household socio-economic, demographic, geographic, family and dwelling attributes influence the total household energy requirements. There are also large variations in the pattern of energy requirements across households belonging to different expenditure classes. Results from the econometric estimation show that total household expenditure or income level is the most important explanatory variable causing variation in energy requirements across households. In addition, the size of the household dwelling and the age of the head of the household are related to higher household energy requirements. In contrast, the number of members in the household and literacy of the head are associated with lower household energy requirements.

  2. Technical assessment of compliance with work place air sampling requirements at T Plant. Revision No. 1

    International Nuclear Information System (INIS)

    Hackworth, M.F.

    1995-01-01

    The US DOE requires its contractors to conduct air sampling to detect and evaluate airborne radioactive material in the workplace. Hanford Reservation T Plant compliance with workplace air sampling requirements has been assessed. Requirements, basis for determining compliance and recommendations are included

  3. Technical assessment of compliance with workplace air sampling requirements in the 300 Area

    International Nuclear Information System (INIS)

    Olsen, P.A.

    1995-01-01

    The purpose of this Technical Work Document is to satisfy HSRCM-1, the ''Hanford Site Radiological Control Manual.'' Article 551.4 of that manual states a requirement for a documented study of facility workplace air sampling programs (WPAS). This first revision of the original Supporting Document covers the period from January 1, 1995 to December 31, 1995. HSRCM-1 is the primary guidance for radiological control at Westinghouse Hanford Company (WHC). It was written to implement DOE/EH-0256T ''US Department of Energy Radiological Control Manual'' as it applies to programs at Hanford. As such, it complies with Title 10, Part 835 of the Code of Federal Regulations. There are also several Department of Energy (DOE) Orders, national consensus standards, and reports that provide criteria, standards, and requirements for workplace air sampling programs. This document provides a summary of these, as they apply to WHC facility workplace air sampling programs. This document also provides an evaluation of the compliance of 300 Areas' workplace air sampling program to the criteria, standards, and requirements and documents compliance with the requirements where appropriate. Where necessary, it also indicates changes needed to bring specific locations into compliance. The areas evaluated were the 340 Facility, the Advanced Reactor Operations Division Facilities, the N Reactor Fuels Supply Facility, and The Geotechnical Engineering Laboratory

  4. Determination of total alpha activity index in samples of radioactive wastes

    International Nuclear Information System (INIS)

    Galicia C, F. J.

    2015-01-01

    This study aimed to develop a methodology of preparation and quantification of samples containing radionuclides beta and/or alpha emitters, to determine the rates of alpha and beta total activity of radioactive waste samples. For this, a device of planchettes preparer was designed, to assist the planchettes preparation in a controlled environment and free of corrosive vapors. Planchettes were prepared in three means: nitrate, carbonate and sulfate, to different mass thickness, natural uranium (alpha and beta emitter) and in case of Sr-90 (beta emitter pure) only in half nitrate; and these planchettes were quantified in an alpha/beta counter, in order to construct the self-absorption curves for alpha and beta particles. These curves are necessary to determine the rate of alpha-beta activity of any sample because they provide the self-absorption correction factor to be applied in calculating the index. Samples with U were prepared with the help of the device of planchettes preparer and subsequently were analyzed in the proportional counter Mpc-100 Pic brand. Samples with Sr-90 were prepared without the device to see if there was a different behavior with respect to obtaining mass thickness. Similarly they were calcined and carried out count in the Mpc-100. To perform the count, first the parameters of counter operating were determined: operating voltages for alpha and beta particles 630 and 1500 V respectively, a count routine was generated where the time and count type were adjusted, and counting efficiencies for alpha and beta particles, with the aid of calibration sources of 210 Po for alphas and 90 Sr for betas. According to the results, the counts per minute will decrease as increasing the mass thickness of the sample (self-absorption curve), adjusting this behavior to an exponential function in all cases studied. The minor self-absorption of alpha and beta particles in the case of U was obtained in sulfate medium. The self-absorption curves of Sr-90 follow the

  5. Technical assessment of workplace air sampling requirements at tank farm facilities. Revision 1

    International Nuclear Information System (INIS)

    Olsen, P.A.

    1994-01-01

    WHC-CM-1-6 is the primary guidance for radiological control at Westinghouse Hanford Company (WHC). It was written to implement DOE N 5480.6 ''US Department of Energy Radiological Control Manual'' as it applies to programs at Hanford which are now overseen by WHC. As such, it complies with Title 10, Part 835 of the Code of Federal Regulations. In addition to WHC-CM-1-6, there is HSRCM-1, the ''Hanford Site Radiological Control Manual'' and several Department of Energy (DOE) Orders, national consensus standards, and reports that provide criteria, standards, and requirements for workplace air sampling programs. This document provides a summary of these, as they apply to WHC facility workplace air sampling programs. This document also provides an evaluation of the compliance of Tank Farms' workplace air sampling program to the criteria, standards, and requirements and documents compliance with the requirements where appropriate. Where necessary, it also indicates changes needed to bring specific locations into compliance

  6. Pesticides, selected elements, and other chemicals in adult total diet samples October 1979-September 1980

    International Nuclear Information System (INIS)

    Gartrell, M.J.; Craun, J.C.; Podrebarac, D.S.; Gunderson, E.L.

    1985-01-01

    The US Food and Drug Administration (FDA) conducts Total Diet Studies to determine the dietary intake of selected pesticides, industrial chemicals, and elements (including radionuclides). These studies involve the retail purchase and analysis of foods representative of the diets of infants, toddlers, and adults. The individual food items are separated into a number of food groups, each of which is analyzed as a composite. This report summarizes the results for adult Total Diet samples collected in 20 cities between October 1979 and September 1980. The average concentration, range of concentrations, and calculated average daily intake of each chemical found are presented by food group. The average daily intakes of the chemicals are similar to those found in the several preceding years and are within acceptable limits. The results for samples collected during the same period that represent the diets of infants and toddlers are reported separately

  7. 40 CFR 80.335 - What gasoline sample retention requirements apply to refiners and importers?

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 16 2010-07-01 2010-07-01 false What gasoline sample retention... PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) REGULATION OF FUELS AND FUEL ADDITIVES Gasoline Sulfur Sampling, Testing and Retention Requirements for Refiners and Importers § 80.335 What gasoline sample...

  8. A sensitive method for determining total vanadium in water samples using colorimetric-solid-phase extraction-fiber optic reflectance spectroscopy

    International Nuclear Information System (INIS)

    Filik, Hayati; Yanaz, Zeynep

    2009-01-01

    A selective colorimetric-solid-phase extraction (C-SPE) method for the determination of total vanadium in water samples was developed. This method introduced a new variation of C-SPE. The colour reaction is based on the reaction of vanadium(V) ternary complex formed with 1-(2-Pyridylazo)-2-naphtol (PAN) in the presence hydrogen peroxide (H 2 O 2 ). In this technique, the target analytes in samples are extracted onto solid matrix loaded with a colorimetric reagent and then quantified directly on the adsorbent surface by using a miniature fiber optic reflectance spectrometer. The measurements were carried out at a wavelength of 589.4 nm since it yielded the largest divergence different in reflectance spectra before and after reaction with the vanadium. The overall time required for the C-SPE procedure was ∼20 min. The amount of concentrated V is then determined in a few seconds by using miniature reflectance spectrometer. At the optimal conditions, a calibration curve was constructed, revealing a linear range of 0.05-0.52 mg L -1 and a detection limit as low as 0.01 mg L -1 while the RSD lower than 2.8%. In order to verify the accuracy of the method, a certified reference water samples (TMDA) were analysed and the results obtained were in good agreement with the certified values. The proposed method was applied to the determination of vanadium in tap water, seawater samples with a recovery for the spiked samples in the range of 98-102%.

  9. Static, Mixed-Array Total Evaporation for Improved Quantitation of Plutonium Minor Isotopes in Small Samples

    Science.gov (United States)

    Stanley, F. E.; Byerly, Benjamin L.; Thomas, Mariam R.; Spencer, Khalil J.

    2016-06-01

    Actinide isotope measurements are a critical signature capability in the modern nuclear forensics "toolbox", especially when interrogating anthropogenic constituents in real-world scenarios. Unfortunately, established methodologies, such as traditional total evaporation via thermal ionization mass spectrometry, struggle to confidently measure low abundance isotope ratios (evaporation techniques as a straightforward means of improving plutonium minor isotope measurements, which have been resistant to enhancement in recent years because of elevated radiologic concerns. Results are presented for small sample (~20 ng) applications involving a well-known plutonium isotope reference material, CRM-126a, and compared with traditional total evaporation methods.

  10. Automated determination of the stable carbon isotopic composition (δ13C) of total dissolved inorganic carbon (DIC) and total nonpurgeable dissolved organic carbon (DOC) in aqueous samples: RSIL lab codes 1851 and 1852

    Science.gov (United States)

    Révész, Kinga M.; Doctor, Daniel H.

    2014-01-01

    The purposes of the Reston Stable Isotope Laboratory (RSIL) lab codes 1851 and 1852 are to determine the total carbon mass and the ratio of the stable isotopes of carbon (δ13C) for total dissolved inorganic carbon (DIC, lab code 1851) and total nonpurgeable dissolved organic carbon (DOC, lab code 1852) in aqueous samples. The analysis procedure is automated according to a method that utilizes a total carbon analyzer as a peripheral sample preparation device for analysis of carbon dioxide (CO2) gas by a continuous-flow isotope ratio mass spectrometer (CF-IRMS). The carbon analyzer produces CO2 and determines the carbon mass in parts per million (ppm) of DIC and DOC in each sample separately, and the CF-IRMS determines the carbon isotope ratio of the produced CO2. This configuration provides a fully automated analysis of total carbon mass and δ13C with no operator intervention, additional sample preparation, or other manual analysis. To determine the DIC, the carbon analyzer transfers a specified sample volume to a heated (70 °C) reaction vessel with a preprogrammed volume of 10% phosphoric acid (H3PO4), which allows the carbonate and bicarbonate species in the sample to dissociate to CO2. The CO2 from the reacted sample is subsequently purged with a flow of helium gas that sweeps the CO2 through an infrared CO2 detector and quantifies the CO2. The CO2 is then carried through a high-temperature (650 °C) scrubber reactor, a series of water traps, and ultimately to the inlet of the mass spectrometer. For the analysis of total dissolved organic carbon, the carbon analyzer performs a second step on the sample in the heated reaction vessel during which a preprogrammed volume of sodium persulfate (Na2S2O8) is added, and the hydroxyl radicals oxidize the organics to CO2. Samples containing 2 ppm to 30,000 ppm of carbon are analyzed. The precision of the carbon isotope analysis is within 0.3 per mill for DIC, and within 0.5 per mill for DOC.

  11. Determination of total organic phosphorus in samples of mineral soils

    Directory of Open Access Journals (Sweden)

    Armi Kaila

    1962-01-01

    Full Text Available In this paper some observations on the estimation of organic phosphorus in mineral soils are reported. The fact is emphasized that the accuracy of all the methods available is relatively poor. Usually, there are no reasons to pay attention to differences less than about 20 ppm. of organic P. Analyses performed on 345 samples of Finnish mineral soils by the extraction method of MEHTA et. al. (10 and by a simple procedure adopted by the author (successive extractions with 4 N H2SO4 and 0.5 N NaOH at room temperature in the ratio of 1 to 100 gave, on the average, equal results. It seemed to be likely that the MEHTA method removed the organic phosphorus more completely than did the less vigorous method, but in the former the partial hydrolysis of organic phosphorus compounds tends to be higher than in the latter. An attempt was made to find out whether the differences between the respective values for organic phosphorus obtained by an ignition method and the simple extraction method could be connected with any characteristics of the soil. No correlation or only a low correlation coefficient could be calculated between the difference in the results of these two methods and e. g. the pH-value, the content of clay, organic carbon, aluminium and iron soluble in Tamm’s acid oxalate, the indicator of the phosphate sorption capacity, or the »Fe-bound» inorganic phosphorus, respectively. The absolute difference tended to increase with an increase in the content of organic phosphorus. For the 250 samples of surface soils analyzed, the ignition method gave values which were, on the average, about 50 ppm. higher than the results obtained by the extraction procedure. The corresponding difference for the 120 samples from deeper layers was about 20 ppm of organic P. The author recommends, for the present, the determination of the total soil organic phosphorus as an average of the results obtained by the ignition method and the extraction method.

  12. Electrochemical sensing of total antioxidant capacity and polyphenol content in wine samples using amperometry online-coupled with microdialysis.

    Science.gov (United States)

    Jakubec, Petr; Bancirova, Martina; Halouzka, Vladimir; Lojek, Antonin; Ciz, Milan; Denev, Petko; Cibicek, Norbert; Vacek, Jan; Vostalova, Jitka; Ulrichova, Jitka; Hrbac, Jan

    2012-08-15

    This work describes the method for total antioxidant capacity (TAC) and/or total content of phenolics (TCP) analysis in wines using microdialysis online-coupled with amperometric detection using a carbon microfiber working electrode. The system was tested on 10 selected wine samples, and the results were compared with total reactive antioxidant potential (TRAP), oxygen radical absorbance capacity (ORAC), and chemiluminescent determination of total antioxidant capacity (CL-TAC) methods using Trolox and catechin as standards. Microdialysis online-coupled with amperometric detection gives similar results to the widely used cyclic voltammetry methodology and closely correlates with ORAC and TRAP. The problem of electrode fouling is overcome by the introduction of an electrochemical cleaning step (1-2 min at the potential of 0 V vs Ag/AgCl). Such a procedure is sufficient to fully regenerate the electrode response for both red and white wine samples as well as catechin/Trolox standards. The appropriate size of microdialysis probes enables easy automation of the electrochemical TAC/TCP measurement using 96-well microtitration plates.

  13. Sample Size Requirements for Assessing Statistical Moments of Simulated Crop Yield Distributions

    NARCIS (Netherlands)

    Lehmann, N.; Finger, R.; Klein, T.; Calanca, P.

    2013-01-01

    Mechanistic crop growth models are becoming increasingly important in agricultural research and are extensively used in climate change impact assessments. In such studies, statistics of crop yields are usually evaluated without the explicit consideration of sample size requirements. The purpose of

  14. A totally automatic density meter for radioactive solutions

    International Nuclear Information System (INIS)

    Hochel, R.C.

    1987-02-01

    A totally automatic density meter for measuring the density of radioactive liquid (plutonium nitrate) samples was developed and built for use at the Savannah River Plant. The measurement cell (vibrating U-tube) and other wetted parts are glovebox-contained and are remoted from the electronics and control instrumentation. The only operator actions required are insertion of a sample vial into the system, starting the analysis, and removing the vial about 90 seconds later. The sample measurement takes about 3 to 4 minutes and uses 10 mL of sample; another 5 to 6 minutes is required for a water/air measurement-control check, which leaves the system ready for the next sample. No water bath is needed because a computer algorithm is applied to the measurement to correct it to a standard reference temperature. The system is normally operated under computer control, but a programmable logic controller is available for backup. The system may also be operated manually by means of a switchpanel. 5 refs., 3 figs

  15. Prediction equation for estimating total daily energy requirements of special operations personnel.

    Science.gov (United States)

    Barringer, N D; Pasiakos, S M; McClung, H L; Crombie, A P; Margolis, L M

    2018-01-01

    Special Operations Forces (SOF) engage in a variety of military tasks with many producing high energy expenditures, leading to undesired energy deficits and loss of body mass. Therefore, the ability to accurately estimate daily energy requirements would be useful for accurate logistical planning. Generate a predictive equation estimating energy requirements of SOF. Retrospective analysis of data collected from SOF personnel engaged in 12 different SOF training scenarios. Energy expenditure and total body water were determined using the doubly-labeled water technique. Physical activity level was determined as daily energy expenditure divided by resting metabolic rate. Physical activity level was broken into quartiles (0 = mission prep, 1 = common warrior tasks, 2 = battle drills, 3 = specialized intense activity) to generate a physical activity factor (PAF). Regression analysis was used to construct two predictive equations (Model A; body mass and PAF, Model B; fat-free mass and PAF) estimating daily energy expenditures. Average measured energy expenditure during SOF training was 4468 (range: 3700 to 6300) Kcal·d- 1 . Regression analysis revealed that physical activity level ( r  = 0.91; P  plan appropriate feeding regimens to meet SOF nutritional requirements across their mission profile.

  16. Comparison of total Hg results in sediment samples from Rio Grande reservoir determine by NAA and CV AAS

    International Nuclear Information System (INIS)

    Franklin, Robson L.

    2011-01-01

    The Rio Grande reservoir is located in the Metropolitan area of Sao Paulo and it is used for recreation purposes and as source water for drinking water production. During the last decades has been detected mercury contamination in the sediments of this reservoir, mainly in the eastern part, near the main affluent of the reservoir, in the Rio Grande da Serra and Ribeirao Pires counties. In the present study bottom sediment samples were collected in four different sites into four sampling campaigns during the period of September 2008 to January 2010. The samples were dried at room temperature, ground and passed through a 2 mm sieve. Total Hg determination in the sediment samples was carried out by two different analytical techniques: neutron activation analysis (NAA) and cold vapor atomic absorption spectrometry (CV AAS). The methodology validation, in terms of precision and accuracy, was performed by reference materials, and presented a recovery of 83 to 108%. The total Hg results obtained by both analytical techniques ranged from 3 to 71 mg kg-1 and were considered similar by statistical analysis, even though NAA technique furnishes the total concentration while CV AAS using the 3015 digestion procedure characterizes only the bioavailable Hg. These results confirm that both analytical techniques were suitable to detect the Hg concentration levels in the Rio Grande sediments studied. The Hg levels in the sediment of the Rio Grande reservoir confirm the anthropogenic origin for this element in this ecosystem. (author)

  17. Spatial distribution and trends of total mercury in waters of the Great Lakes and connecting channels using an improved sampling technique

    International Nuclear Information System (INIS)

    Dove, A.; Hill, B.; Klawunn, P.; Waltho, J.; Backus, S.; McCrea, R.C.

    2012-01-01

    Environment Canada recently developed a clean method suitable for sampling trace levels of metals in surface waters. The results of sampling for total mercury in the Laurentian Great Lakes between 2003 and 2009 give a unique basin-wide perspective of concentrations of this important contaminant and represent improved knowledge of mercury in the region. Results indicate that concentrations of total mercury in the offshore regions of the lakes were within a relatively narrow range from about 0.3 to 0.8 ng/L. The highest concentrations were observed in the western basin of Lake Erie and concentrations then declined towards the east. Compared to the offshore, higher levels were observed at some nearshore locations, particularly in lakes Erie and Ontario. The longer-term temporal record of mercury in Niagara River suspended sediments indicates an approximate 30% decrease in equivalent water concentrations since 1986. - Highlights: ► Basin-wide concentrations of total mercury in Great Lakes surface waters are provided for the first time. ► A clean sampling method is described, stressing isolation of the sample from extraneous sources of contamination. ► Sub-ng/L concentrations of total mercury are observed in most Great Lakes offshore areas. ► Concentrations in the western basin of Lake Erie are consistently the highest observed in the basin. ► The longer-term record of mercury in Niagara River suspended sediments indicates an approximate 30% decrease since 1986. - A new, clean sampling method for metals is described and basin-wide measurements of total mercury are provided for Great Lakes surface waters for the first time.

  18. Simultaneous Effects of Total Solids Content, Milk Base, Heat Treatment Temperature and Sample Temperature on the Rheological Properties of Plain Stirred Yogurt

    Directory of Open Access Journals (Sweden)

    Attilio Converti

    2006-01-01

    Full Text Available Response surface methodology was used to establish a relationship between total solids content, milk base, heat treatment temperature, and sample temperature, and consistency index, flow behaviour index, and apparent viscosity of plain stirred yogurts. Statistical treatments resulted in developments of mathematical models. All samples presented shear thinning fluid behaviour. The increase of the content of total solids (9.3–22.7 % and milk base heat treatment temperature (81.6–98.4 °C resulted in a significant increase in consistency index and a decrease in flow behaviour index. Increase in the sample temperature (1.6–18.4 °C caused a decrease in consistency index and increase in flow behaviour index. Apparent viscosity was directly related to the content of total solids. Rheological properties of yogurt were highly dependent on the content of total solids in milk.

  19. Develop of omni-tritium sample preparation device

    International Nuclear Information System (INIS)

    Tian Junhua; Zheng Min; Zhang Dong

    2008-06-01

    The content of total tritium analysis is required in order to know the tritium contaminated degree of biological samples accurately. But the conversion and collection of organic tritium are difficult. A device to treat total tritium samples was developed. Plant samples were treated by combustion and catalysis. After expelling the free HTO in the samples when heated in abundant oxygen, the samples were ignited. Combustion gas passed the catalysts at 800 degree C and its oxidation was catalyzed, and then the combined tritium in tissues was converted into HTO. HTO was collected by water-cooling tube and condenser. For other samples, HTO was treated and collected by high temperature (The highest temperature is 1000 degree C)-catalysis-double condensation method. This device had solved the problem that organic tritium is difficult to gather. (authors)

  20. Portable ultrahigh-vacuum sample storage system for polarization-dependent total-reflection fluorescence x-ray absorption fine structure spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Watanabe, Yoshihide, E-mail: e0827@mosk.tytlabs.co.jp; Nishimura, Yusaku F.; Suzuki, Ryo; Beniya, Atsushi; Isomura, Noritake [Toyota Central R& D Labs., Inc., Yokomichi 41-1, Nagakute, Aichi 480-1192 (Japan); Uehara, Hiromitsu; Asakura, Kiyotaka; Takakusagi, Satoru [Catalysis Research Center, Hokkaido University, Kita 21-10, Sapporo, Hokkaido 001-0021 (Japan); Nimura, Tomoyuki [AVC Co., Ltd., Inada 1450-6, Hitachinaka, Ibaraki 312-0061 (Japan)

    2016-03-15

    A portable ultrahigh-vacuum sample storage system was designed and built to investigate the detailed geometric structures of mass-selected metal clusters on oxide substrates by polarization-dependent total-reflection fluorescence x-ray absorption fine structure spectroscopy (PTRF-XAFS). This ultrahigh-vacuum (UHV) sample storage system provides the handover of samples between two different sample manipulating systems. The sample storage system is adaptable for public transportation, facilitating experiments using air-sensitive samples in synchrotron radiation or other quantum beam facilities. The samples were transferred by the developed portable UHV transfer system via a public transportation at a distance over 400 km. The performance of the transfer system was demonstrated by a successful PTRF-XAFS study of Pt{sub 4} clusters deposited on a TiO{sub 2}(110) surface.

  1. Method Performance of Total Mercury (Hg) Testing in the Biological Samples by Using Cold Vapour Atomic Absorption Spectrophotometer (CV-AAS)

    International Nuclear Information System (INIS)

    Susanna TS; Samin

    2007-01-01

    Method performance (validation) of total mercury (Hg) testing in the biological samples by using cold vapour atomic absorption spectrophotometer (CV-AAS) has been done. The objective of this research is to know the method performance of CV-AAS as one of points for the accreditation testing of laboratory according IS0/IEC 17025-2005. The method performance covering limit of detection (LOD), accuracy, precision and bias. As a standard material used SRM Oyster Tissue 15660 from Winopal Forshung Germany, whereas the biological samples were human hair. In principle of mercury testing for solid samples using CV-AAS is dissolving this sample and standard with 10 mL HNO 3 supra pure into a closed quartz tube and heating at 150 °C for 4 hours. The concentration of mercury in each samples was determined at the condition of operation were stirring time (T 1 ) 70 seconds, delay time (T 2 ) 15 seconds, heating time (T 3 ) 13 seconds and cooling time (T 4 ) of 25 seconds. Mercury ion in samples are reduced with SnCl 2 10 % in H 2 SO 4 20 %, and then the vapour of mercury from reduction is passed in NaOH 20 % solution and aquatridest. The result of method performance were: limit of detection (LOD) = 0.085 ng, accuracy 99.70 %, precision (RSD) = 1.64 % and bias = 0.30 %. From the validation result showed that the content of mercury total was in the range of certified values. The total mercury content (Hg) in human hair were varied from 406.93 - 699.07 ppb. (author)

  2. Data Quality Objectives for Regulatory Requirements for Dangerous Waste Sampling and Analysis

    International Nuclear Information System (INIS)

    MULKEY, C.H.

    1999-01-01

    This document describes sampling and analytical requirements needed to meet state and federal regulations for dangerous waste (DW). The River Protection Project (RPP) is assigned to the task of storage and interim treatment of hazardous waste. Any final treatment or disposal operations, as well as requirements under the land disposal restrictions (LDRs), fall in the jurisdiction of another Hanford organization and are not part of this scope. The requirements for this Data Quality Objective (DQO) Process were developed using the RPP Data Quality Objective Procedure (Banning 1996), which is based on the U.S. Environmental Protection Agency's (EPA) Guidance for the Data Quality Objectives Process (EPA 1994). Hereafter, this document is referred to as the DW DQO. Federal and state laws and regulations pertaining to waste contain requirements that are dependent upon the composition of the waste stream. These regulatory drivers require that pertinent information be obtained. For many requirements, documented process knowledge of a waste composition can be used instead of analytical data to characterize or designate a waste. When process knowledge alone is used to characterize a waste, it is a best management practice to validate the information with analytical measurements

  3. Solid fat content as a substitute for total polar compound analysis in edible oils

    Science.gov (United States)

    The solid fat contents (SFC) of heated edible oil samples were measured and found to correlate positively with total polar compounds (TPC) and inversely with triglyceride concentration. Traditional methods for determination of total polar compounds require a laboratory setting and are time intensiv...

  4. Feedback Blunting: Total Sleep Deprivation Impairs Decision Making that Requires Updating Based on Feedback

    Science.gov (United States)

    Whitney, Paul; Hinson, John M.; Jackson, Melinda L.; Van Dongen, Hans P.A.

    2015-01-01

    Study Objectives: To better understand the sometimes catastrophic effects of sleep loss on naturalistic decision making, we investigated effects of sleep deprivation on decision making in a reversal learning paradigm requiring acquisition and updating of information based on outcome feedback. Design: Subjects were randomized to a sleep deprivation or control condition, with performance testing at baseline, after 2 nights of total sleep deprivation (or rested control), and following 2 nights of recovery sleep. Subjects performed a decision task involving initial learning of go and no go response sets followed by unannounced reversal of contingencies, requiring use of outcome feedback for decisions. A working memory scanning task and psychomotor vigilance test were also administered. Setting: Six consecutive days and nights in a controlled laboratory environment with continuous behavioral monitoring. Subjects: Twenty-six subjects (22–40 y of age; 10 women). Interventions: Thirteen subjects were randomized to a 62-h total sleep deprivation condition; the others were controls. Results: Unlike controls, sleep deprived subjects had difficulty with initial learning of go and no go stimuli sets and had profound impairment adapting to reversal. Skin conductance responses to outcome feedback were diminished, indicating blunted affective reactions to feedback accompanying sleep deprivation. Working memory scanning performance was not significantly affected by sleep deprivation. And although sleep deprived subjects showed expected attentional lapses, these could not account for impairments in reversal learning decision making. Conclusions: Sleep deprivation is particularly problematic for decision making involving uncertainty and unexpected change. Blunted reactions to feedback while sleep deprived underlie failures to adapt to uncertainty and changing contingencies. Thus, an error may register, but with diminished effect because of reduced affective valence of the feedback

  5. Quality assurance and reference material requirements and considerations for environmental sample analysis in nuclear forensics

    International Nuclear Information System (INIS)

    Swindle, D.W. Jr.; Perrin, R.E.; Goldberg, S.A.; Cappis, J.

    2002-01-01

    Full text: High-sensitivity nuclear environmental sampling and analysis techniques have been proven in their ability to verify declared nuclear activities, as well as to assist in the detection of undeclared nuclear activities and facilities. Following the Gulf War, the capability and revealing power of environmental sampling and analysis techniques to support international safeguards was demonstrated and subsequently adopted by the International Atomic Energy Agency (IAEA) as routine safeguards measures in safeguards inspections and verifications. In addition to having been proved useful in international safeguards, environmental sampling and analysis techniques have demonstrated their utility in identifying the origins of 'orphaned' nuclear material, as well as the origin of intercepted smuggled nuclear material. Today, environmental sampling and analysis techniques are now being applied in six broad areas to support nonproliferation, disarmament treaty verification, national and international nuclear security, and environmental stewardship of weapons production activities. Consequently, more and more laboratories around the world are establishing capabilities or expanding capabilities to meet these growing applications, and as such requirements for quality assurance and control are increasing. The six areas are: 1) Nuclear safeguards; 2) Nuclear forensics/illicit trafficking; 3) Ongoing monitoring and verification (OMV); 4) Comprehensive Test Ban Treaty (CTBT); 5) Weapons dismantlement/materials disposition; and 6) Research and development (R and D)/environmental stewardship/safety. Application of environmental sampling and analysis techniques and resources to illicit nuclear material trafficking, while embodying the same basic techniques and resources, does have unique requirements for sample management, handling, protocols, chain of custody, archiving, and data interpretation. These requirements are derived from needs of how data from nuclear forensics

  6. Sample size estimation and sampling techniques for selecting a representative sample

    Directory of Open Access Journals (Sweden)

    Aamir Omair

    2014-01-01

    Full Text Available Introduction: The purpose of this article is to provide a general understanding of the concepts of sampling as applied to health-related research. Sample Size Estimation: It is important to select a representative sample in quantitative research in order to be able to generalize the results to the target population. The sample should be of the required sample size and must be selected using an appropriate probability sampling technique. There are many hidden biases which can adversely affect the outcome of the study. Important factors to consider for estimating the sample size include the size of the study population, confidence level, expected proportion of the outcome variable (for categorical variables/standard deviation of the outcome variable (for numerical variables, and the required precision (margin of accuracy from the study. The more the precision required, the greater is the required sample size. Sampling Techniques: The probability sampling techniques applied for health related research include simple random sampling, systematic random sampling, stratified random sampling, cluster sampling, and multistage sampling. These are more recommended than the nonprobability sampling techniques, because the results of the study can be generalized to the target population.

  7. Concentrations of bisphenol A in the composite food samples from the 2008 Canadian total diet study in Quebec City and dietary intake estimates

    OpenAIRE

    Cao, X.-L.; Perez-Locas, C.; Dufresne, G.; Clement, G.; Popovic, S.; Beraldin, F.; Dabeka, R.W.; Feeley, M.

    2011-01-01

    A total of 154 food composite samples from the 2008 total diet study in Quebec City were analysed for bisphenol A (BPA), and BPA was detected in less than half (36%, or 55 samples) of the samples tested. High concentrations of BPA were found mostly in the composite samples containing canned foods, with the highest BPA level being observed in canned fish (106 ng g−1), followed by canned corn (83.7 ng g−1), canned soups (22.2–44.4 ng g−1), canned baked beans (23.5 ng g−1), canned peas (16.8 ng ...

  8. Total algorithms

    NARCIS (Netherlands)

    Tel, G.

    We define the notion of total algorithms for networks of processes. A total algorithm enforces that a "decision" is taken by a subset of the processes, and that participation of all processes is required to reach this decision. Total algorithms are an important building block in the design of

  9. Sensitive Electrochemical Determination of Gallic Acid: Application in Estimation of Total Polyphenols in Plant Samples

    Directory of Open Access Journals (Sweden)

    Mohammad Ali Sheikh-Mohseni

    2016-12-01

    Full Text Available A modified electrode was prepared by modification of the carbon paste electrode (CPE with graphene nano-sheets. The fabricated modified electrode exhibited an electrocatalytic activity toward gallic acid (GA oxidation because of good conductivity, low electron transfer resistance and catalytic effect. The graphene modified CPE had a lower overvoltage and enhanced electrical current respect to the bare CPE for the oxidation of GA. The oxidation potential of GA decreased more than 210 mV by the modified electrode. The modified electrode responded to the GA in the concentration range of 3.0 × 10-5-1.5 × 10-4 M with high sensitivity by the technique of differential pulse voltammetry. Also, detection limit of 1.1 × 10-7 M was obtained by this modified electrode for GA. This electrode was used for the successful determination of GA in plant samples. Therefore, the content of total polyphenols in plant samples can be determined by the proposed modified electrode based on the concentration of GA in the sample.

  10. Evaluation of Total Nitrite Pattern Visualization as an Improved Method for Gunshot Residue Detection and its Application to Casework Samples.

    Science.gov (United States)

    Berger, Jason; Upton, Colin; Springer, Elyah

    2018-04-23

    Visualization of nitrite residues is essential in gunshot distance determination. Current protocols for the detection of nitrites include, among other tests, the Modified Griess Test (MGT). This method is limited as nitrite residues are unstable in the environment and limited to partially burned gunpowder. Previous research demonstrated the ability of alkaline hydrolysis to convert nitrates to nitrites, allowing visualization of unburned gunpowder particles using the MGT. This is referred to as Total Nitrite Pattern Visualization (TNV). TNV techniques were modified and a study conducted to streamline the procedure outlined in the literature to maximize the efficacy of the TNV in casework, while reducing the required time from 1 h to 5 min, and enhancing effectiveness on blood-soiled samples. The TNV method was found to provide significant improvement in the ability to detect significant nitrite residues, without sacrificing efficiency, that would allow for the determination of the muzzle-to-target distance. © 2018 American Academy of Forensic Sciences.

  11. Dose optimization with first-order total-variation minimization for dense angularly sampled and sparse intensity modulated radiation therapy (DASSIM-RT)

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hojin; Li Ruijiang; Lee, Rena; Goldstein, Thomas; Boyd, Stephen; Candes, Emmanuel; Xing Lei [Department of Electrical Engineering, Stanford University, Stanford, California 94305-9505 (United States) and Department of Radiation Oncology, Stanford University, Stanford, California 94305-5847 (United States); Department of Radiation Oncology, Stanford University, Stanford, California 94305-5847 (United States); Department of Radiation Oncology, Ehwa University, Seoul 158-710 (Korea, Republic of); Department of Electrical Engineering, Stanford University, Stanford, California 94305-9505 (United States); Department of Statistics, Stanford University, Stanford, California 94305-4065 (United States); Department of Radiation Oncology, Stanford University, Stanford, California 94305-5304 (United States)

    2012-07-15

    Purpose: A new treatment scheme coined as dense angularly sampled and sparse intensity modulated radiation therapy (DASSIM-RT) has recently been proposed to bridge the gap between IMRT and VMAT. By increasing the angular sampling of radiation beams while eliminating dispensable segments of the incident fields, DASSIM-RT is capable of providing improved conformity in dose distributions while maintaining high delivery efficiency. The fact that DASSIM-RT utilizes a large number of incident beams represents a major computational challenge for the clinical applications of this powerful treatment scheme. The purpose of this work is to provide a practical solution to the DASSIM-RT inverse planning problem. Methods: The inverse planning problem is formulated as a fluence-map optimization problem with total-variation (TV) minimization. A newly released L1-solver, template for first-order conic solver (TFOCS), was adopted in this work. TFOCS achieves faster convergence with less memory usage as compared with conventional quadratic programming (QP) for the TV form through the effective use of conic forms, dual-variable updates, and optimal first-order approaches. As such, it is tailored to specifically address the computational challenges of large-scale optimization in DASSIM-RT inverse planning. Two clinical cases (a prostate and a head and neck case) are used to evaluate the effectiveness and efficiency of the proposed planning technique. DASSIM-RT plans with 15 and 30 beams are compared with conventional IMRT plans with 7 beams in terms of plan quality and delivery efficiency, which are quantified by conformation number (CN), the total number of segments and modulation index, respectively. For optimization efficiency, the QP-based approach was compared with the proposed algorithm for the DASSIM-RT plans with 15 beams for both cases. Results: Plan quality improves with an increasing number of incident beams, while the total number of segments is maintained to be about the

  12. Sample size requirements for one-year treatment effects using deep gray matter volume from 3T MRI in progressive forms of multiple sclerosis.

    Science.gov (United States)

    Kim, Gloria; Chu, Renxin; Yousuf, Fawad; Tauhid, Shahamat; Stazzone, Lynn; Houtchens, Maria K; Stankiewicz, James M; Severson, Christopher; Kimbrough, Dorlan; Quintana, Francisco J; Chitnis, Tanuja; Weiner, Howard L; Healy, Brian C; Bakshi, Rohit

    2017-11-01

    The subcortical deep gray matter (DGM) develops selective, progressive, and clinically relevant atrophy in progressive forms of multiple sclerosis (PMS). This patient population is the target of active neurotherapeutic development, requiring the availability of outcome measures. We tested a fully automated MRI analysis pipeline to assess DGM atrophy in PMS. Consistent 3D T1-weighted high-resolution 3T brain MRI was obtained over one year in 19 consecutive patients with PMS [15 secondary progressive, 4 primary progressive, 53% women, age (mean±SD) 50.8±8.0 years, Expanded Disability Status Scale (median, range) 5.0, 2.0-6.5)]. DGM segmentation applied the fully automated FSL-FIRST pipeline ( http://fsl.fmrib.ox.ac.uk ). Total DGM volume was the sum of the caudate, putamen, globus pallidus, and thalamus. On-study change was calculated using a random-effects linear regression model. We detected one-year decreases in raw [mean (95% confidence interval): -0.749 ml (-1.455, -0.043), p = 0.039] and annualized [-0.754 ml/year (-1.492, -0.016), p = 0.046] total DGM volumes. A treatment trial for an intervention that would show a 50% reduction in DGM brain atrophy would require a sample size of 123 patients for a single-arm study (one-year run-in followed by one-year on-treatment). For a two-arm placebo-controlled one-year study, 242 patients would be required per arm. The use of DGM fraction required more patients. The thalamus, putamen, and globus pallidus, showed smaller effect sizes in their on-study changes than the total DGM; however, for the caudate, the effect sizes were somewhat larger. DGM atrophy may prove efficient as a short-term outcome for proof-of-concept neurotherapeutic trials in PMS.

  13. Background estimation in short-wave region during determination of total sample composition by x-ray fluorescence method

    International Nuclear Information System (INIS)

    Simakov, V.A.; Kordyukov, S.V.; Petrov, E.N.

    1988-01-01

    Method of background estimation in short-wave spectral region during determination of total sample composition by X-ray fluorescence method is described. 13 types of different rocks with considerable variations of base composition and Zr, Nb, Th, U content below 7x10 -3 % are investigated. The suggested method of background accounting provides for a less statistical error of the background estimation than direct isolated measurement and reliability of its determination in a short-wave region independent on the sample base. Possibilities of suggested method for artificial mixtures conforming by the content of main component to technological concemtrates - niobium, zirconium, tantalum are estimated

  14. Determination of total and inorganic mercury in fish samples with on-line oxidation coupled to atomic fluorescence spectrometry

    International Nuclear Information System (INIS)

    Shao Lijun; Gan Wuer; Su Qingde

    2006-01-01

    An atomic fluorescence spectrometry system for determination of total and inorganic mercury with electromagnetic induction-assisted heating on-line oxidation has been developed. Potassium peroxodisulphate was used as the oxidizing agent to decompose organomercury compounds. Depending on the temperature selected, inorganic or total mercury could be determined with the same manifold. Special accent was put on the study of the parameters influencing the on-line digestion efficiency. The tolerance to the interference of coexisting ions was carefully examined in this system. Under optimal conditions, the detection limits (3σ) were evaluated to be 2.9 ng l -1 for inorganic mercury and 2.6 ng l -1 for total mercury, respectively. The relative standard deviations for 10 replicate determinations of 1.0 μg l -1 Hg were 2.4 and 3.2% for inorganic mercury and total mercury, respectively. The proposed method was successfully applied to the determination of total and inorganic mercury in fish samples

  15. Sample requirements and design of an inter-laboratory trial for radiocarbon laboratories

    International Nuclear Information System (INIS)

    Bryant, Charlotte; Carmi, Israel; Cook, Gordon; Gulliksen, Steinar; Harkness, Doug; Heinemeier, Jan; McGee, Edward; Naysmith, Philip; Possnert, Goran; Scott, Marian; Plicht, Hans van der; Strydonck, Mark van

    2000-01-01

    An on-going inter-comparison programme which is focused on assessing and establishing consensus protocols to be applied in the identification, selection and sub-sampling of materials for subsequent 14 C analysis is described. The outcome of the programme will provide a detailed quantification of the uncertainties associated with 14 C measurements including the issues of accuracy and precision. Such projects have become recognised as a fundamental aspect of continuing laboratory quality assurance schemes, providing a mechanism for the harmonisation of measurements and for demonstrating the traceability of results. The design of this study and its rationale are described. In summary, a suite of core samples has been defined which will be made available to both AMS and radiometric laboratories. These core materials are representative of routinely dated material and their ages span the full range of the applied 14 C time-scale. Two of the samples are of wood from the German and Irish dendrochronologies, thus providing a direct connection to the master dendrochronological calibration curve. Further samples link this new inter-comparison to past studies. Sample size and precision have been identified as being of paramount importance in defining dating confidence, and so several core samples have been identified for more in-depth study of these practical issues. In addition to the core samples, optional samples have been identified and prepared specifically for either AMS and/or radiometric laboratories. For AMS laboratories, these include bone, textile, leather and parchment samples. Participation in the study requires a commitment to a minimum of 10 core analyses, with results to be returned within a year

  16. Data Quality Objectives for Regulatory Requirements for Hazardous and Radioactive Air Emissions Sampling and Analysis

    International Nuclear Information System (INIS)

    MULKEY, C.H.

    1999-01-01

    This document describes the results of the data quality objective (DQO) process undertaken to define data needs for state and federal requirements associated with toxic, hazardous, and/or radiological air emissions under the jurisdiction of the River Protection Project (RPP). Hereafter, this document is referred to as the Air DQO. The primary drivers for characterization under this DQO are the regulatory requirements pursuant to Washington State regulations, that may require sampling and analysis. The federal regulations concerning air emissions are incorporated into the Washington State regulations. Data needs exist for nonradioactive and radioactive waste constituents and characteristics as identified through the DQO process described in this document. The purpose is to identify current data needs for complying with regulatory drivers for the measurement of air emissions from RPP facilities in support of air permitting. These drivers include best management practices; similar analyses may have more than one regulatory driver. This document should not be used for determining overall compliance with regulations because the regulations are in constant change, and this document may not reflect the latest regulatory requirements. Regulatory requirements are also expected to change as various permits are issued. Data needs require samples for both radionuclides and nonradionuclide analytes of air emissions from tanks and stored waste containers. The collection of data is to support environmental permitting and compliance, not for health and safety issues

  17. Total inorganic arsenic detection in real water samples using anodic stripping voltammetry and a gold-coated diamond thin-film electrode.

    Science.gov (United States)

    Song, Yang; Swain, Greg M

    2007-06-12

    An accurate method for total inorganic arsenic determination in real water samples was developed using differential pulse anodic stripping voltammetry (DPASV) and a Au-coated boron-doped diamond thin-film electrode. Keys to the method are the use of a conducting diamond platform and solid phase extraction for sample preparation. In the method, the As(III) present in the sample is first detected by DPASV. The As(V) present is then reduced to As(III) by reaction with Na2SO3 and this is followed by a second detection of As(III) by DPASV. Interfering metal ions (e.g., Cu(II)) that cause decreased electrode response sensitivity for arsenic in real samples are removed by solid phase extraction as part of the sample preparation. For example, Cu(II) caused a 30% decrease in the As stripping peak current at a solution concentration ratio of 3:1 (Cu(II)/As(III)). This loss was mitigated by passage of the solution through a Chelex 100 cation exchange resin. After passage, only a 5% As stripping current response loss was seen. The effect of organic matter on the Au-coated diamond electrode response for As(III) was also evaluated. Humic acid at a 5 ppm concentration caused only a 9% decrease in the As stripping peak charge for Au-coated diamond. By comparison, a 50% response decrease was observed for Au foil. Clearly, the chemical properties of the diamond surface in the vicinity of the metal deposits inhibit molecular adsorption on at least some of the Au surface. The method provided reproducible and accurate results for total inorganic arsenic in two contaminated water samples provided by the U.S. Bureau of Reclamation. The total inorganic As concentration in the two samples, quantified by the standard addition method, was 23.2+/-2.9 ppb for UV plant influent water and 16.4+/-0.9 ppb for Well 119 water (n=4). These values differed from the specified concentrations by less than 4%.

  18. Total inorganic arsenic detection in real water samples using anodic stripping voltammetry and a gold-coated diamond thin-film electrode

    International Nuclear Information System (INIS)

    Song Yang; Swain, Greg M.

    2007-01-01

    An accurate method for total inorganic arsenic determination in real water samples was developed using differential pulse anodic stripping voltammetry (DPASV) and a Au-coated boron-doped diamond thin-film electrode. Keys to the method are the use of a conducting diamond platform and solid phase extraction for sample preparation. In the method, the As(III) present in the sample is first detected by DPASV. The As(V) present is then reduced to As(III) by reaction with Na 2 SO 3 and this is followed by a second detection of As(III) by DPASV. Interfering metal ions (e.g., Cu(II)) that cause decreased electrode response sensitivity for arsenic in real samples are removed by solid phase extraction as part of the sample preparation. For example, Cu(II) caused a 30% decrease in the As stripping peak current at a solution concentration ratio of 3:1 (Cu(II)/As(III)). This loss was mitigated by passage of the solution through a Chelex 100 cation exchange resin. After passage, only a 5% As stripping current response loss was seen. The effect of organic matter on the Au-coated diamond electrode response for As(III) was also evaluated. Humic acid at a 5 ppm concentration caused only a 9% decrease in the As stripping peak charge for Au-coated diamond. By comparison, a 50% response decrease was observed for Au foil. Clearly, the chemical properties of the diamond surface in the vicinity of the metal deposits inhibit molecular adsorption on at least some of the Au surface. The method provided reproducible and accurate results for total inorganic arsenic in two contaminated water samples provided by the U.S. Bureau of Reclamation. The total inorganic As concentration in the two samples, quantified by the standard addition method, was 23.2 ± 2.9 ppb for UV plant influent water and 16.4 ± 0.9 ppb for Well 119 water (n = 4). These values differed from the specified concentrations by less than 4%

  19. Matrix effect on the detection limit and accuracy in total reflection X-ray fluorescence analysis of trace elements in environmental and biological samples

    International Nuclear Information System (INIS)

    Karjou, J.

    2007-01-01

    The effect of matrix contents on the detection limit of total reflection X-ray fluorescence analysis was experimentally investigated using a set of multielement standard solutions (500 ng/mL of each element) in variable concentrations of NH 4 NO 3 . It was found that high matrix concentration, i.e. 0.1-10% NH 4 NO 3 , had a strong effect on the detection limits for all investigated elements, whereas no effect was observed at lower matrix concentration, i.e. 0-0.1% NH 4 NO 3 . The effect of soil and blood sample masses on the detection limit was also studied. The results showed decreasing the detection limit (in concentration unit, μg/g) with increasing the sample mass. However, the detection limit increased (in mass unit, ng) with increasing sample mass. The optimal blood sample mass of ca. 200 μg was sufficient to improve the detection limit of Se determination by total reflection X-ray fluorescence. The capability of total reflection X-ray fluorescence to analyze different kinds of samples was discussed with respect to the accuracy and detection limits based on certified and reference materials. Direct analysis of unknown water samples from several sources was also presented in this work

  20. Total and non-seasalt sulfate and chloride measured in bulk precipitation samples from the Kilauea Volcano area, Hawaii

    Science.gov (United States)

    Scholl, M.A.; Ingebritsen, S.E.

    1995-01-01

    Six-month cumulative precipitation samples provide estimates of bulk deposition of sulfate and chloride for the southeast part of the Island of Hawaii during four time periods: August 1991 to February 1992, February 1992 to September 1992, March 1993 to September 1993, and September 1993 to February 1994. Total estimated bulk deposition rates for sulfate ranged from 0.12 to 24 grams per square meter per 180 days, and non-seasalt sulfate deposition ranged from 0.06 to 24 grams per square meter per 180 days. Patterns of non-seasalt sulfate deposition were generally related to prevailing wind directions and the proximity of the collection site to large sources of sulfur gases, namely Kilauea Volcano's summit and East Rift Zone eruption. Total chloride deposition from bulk precipitation samples ranged from 0.01 to 17 grams per square meter per 180 days. Chloride appeared to be predominantly from oceanic sources, as non- seasalt chloride deposition was near zero for most sites.

  1. Gridsampler – A Simulation Tool to Determine the Required Sample Size for Repertory Grid Studies

    Directory of Open Access Journals (Sweden)

    Mark Heckmann

    2017-01-01

    Full Text Available The repertory grid is a psychological data collection technique that is used to elicit qualitative data in the form of attributes as well as quantitative ratings. A common approach for evaluating multiple repertory grid data is sorting the elicited bipolar attributes (so called constructs into mutually exclusive categories by means of content analysis. An important question when planning this type of study is determining the sample size needed to a discover all attribute categories relevant to the field and b yield a predefined minimal number of attributes per category. For most applied researchers who collect multiple repertory grid data, programming a numeric simulation to answer these questions is not feasible. The gridsampler software facilitates determining the required sample size by providing a GUI for conducting the necessary numerical simulations. Researchers can supply a set of parameters suitable for the specific research situation, determine the required sample size, and easily explore the effects of changes in the parameter set.

  2. Determination of the total concentration and speciation of metal ions in river, estuarine and seawater samples.

    Science.gov (United States)

    Alberti, Giancarla; Biesuz, Raffaela; Pesavento, Maria

    2008-12-01

    Different natural water samples were investigated to determine the total concentration and the distribution of species for Cu(II), Pb(II), Al(III) and U(VI). The proposed method, named resin titration (RT), was developed in our laboratory to investigate the distribution of species for metal ions in complex matrices. It is a competition method, in which a complexing resin competes with natural ligands present in the sample to combine with the metal ions. In the present paper, river, estuarine and seawater samples, collected during a cruise in Adriatic Sea, were investigated. For each sample, two RTs were performed, using different complexing resins: the iminodiacetic Chelex 100 and the carboxylic Amberlite CG50. In this way, it was possible to detect different class of ligands. Satisfactory results have been obtained and are commented on critically. They were summarized by principal component analysis (PCA) and the correlations with physicochemical parameters allowed one to follow the evolution of the metals along the considered transect. It should be pointed out that, according to our findings, the ligands responsible for metal ions complexation are not the major components of the water system, since they form considerably weaker complexes.

  3. A CTAB Procedure Of Total Genomic DNA Extraction For Medicinal Mushrooms

    International Nuclear Information System (INIS)

    Azhar Mohamad; Muhammad Hussaini Mohd Mustafa; Muhammad Hanif Azhari Noor; Rosnani Abdul Rashid; Hasan Hamdani Hasan Mutaat; Meswan Meskom; Mat Rasol Awang

    2014-01-01

    Medicinal mushroom is defined as mushrooms used in medicine or medical research. Isolation of intact, high-molecular-mass genomic DNA is essential for many molecular biology applications including Polymerase Chain Reaction (PCR), endonuclease restriction digestion, Southern blot analysis, and genomic library construction. The most important and prerequisite towards reliable molecular biology work is the total genomic DNA of a sample must be in good quality. Five freshly samples of medicinal mushroom were used in this work known as Auriculariapolytricha, Lentinus edode, Pleurotus sayorcaju, Sczhizopyllum commune and Ganodermalucidum. 5 mg of each sample were used to extraction the DNA, prepared in 3 replications and repeated twice. PCR based technique by using ISSR markers were used in checking the amplification ability of the total genomic extraction. A standard Doyle and Doyle protocol for genomic DNA extraction was modified in optimizing the total genomic DNA from the medicinal mushroom.The modification parameters were percentage of CTAB, incubation period and temperature. The results reveal that each sample required a certain combinations of time and period of incubation. Besides, percentage of CTAB in the buffer was found significant in giving a high yielding of extracted total genomic DNA. The extracted total genomic DNA from the medicinal mushroom yielded from 39.7 ng/ μl to 919.1 ng/ μl. The different yield among the samples found to be corresponded to polysaccharide content in the medicinal mushrooms. The objective of this works is to optimize total genomic DNA extraction of medicinal mushrooms towards a high quality intact genomic DNA for molecular activities. (author)

  4. Data Quality Objectives for Regulatory Requirements for Dangerous Waste Sampling and Analysis; FINAL

    International Nuclear Information System (INIS)

    MULKEY, C.H.

    1999-01-01

    This document describes sampling and analytical requirements needed to meet state and federal regulations for dangerous waste (DW). The River Protection Project (RPP) is assigned to the task of storage and interim treatment of hazardous waste. Any final treatment or disposal operations, as well as requirements under the land disposal restrictions (LDRs), fall in the jurisdiction of another Hanford organization and are not part of this scope. The requirements for this Data Quality Objective (DQO) Process were developed using the RPP Data Quality Objective Procedure (Banning 1996), which is based on the U.S. Environmental Protection Agency's (EPA) Guidance for the Data Quality Objectives Process (EPA 1994). Hereafter, this document is referred to as the DW DQO. Federal and state laws and regulations pertaining to waste contain requirements that are dependent upon the composition of the waste stream. These regulatory drivers require that pertinent information be obtained. For many requirements, documented process knowledge of a waste composition can be used instead of analytical data to characterize or designate a waste. When process knowledge alone is used to characterize a waste, it is a best management practice to validate the information with analytical measurements

  5. The Development of Low-Level Measurement Capabilities for Total and Isotopic Uranium in Environmental Samples at Brazilian and Argentine Laboratories by ABACC

    International Nuclear Information System (INIS)

    Guidicini, Olga M.; Olsen, Khris B.; Hembree, Doyle M.; Carter, Joel A.; Whitaker, Michael; Hayes, Susan M.

    2005-01-01

    In June 1998, the Brazilian-Argentine Agency for Accounting and Control of Nuclear Materials (ABACC), with assistance from the U.S. Department of Energy (DOE), began a program to assess environmental sampling and analysis capabilities at laboratories in Argentina and Brazil. The program began with staff training conducted in South America and the United States by Oak Ridge National Laboratory (ORNL) and Pacific Northwest National Laboratory (PNNL). Both laboratories are participating members of DOE's Network of Analytical Laboratories (NWAL) that support IAEA's environmental sampling program. During the initial planning meeting, representatives from ABACC and all the participating analytical laboratories supporting ABACC were briefed on how the first exercise would be managed and on key aspects necessary to analyze low-level environmental samples for uranium. Subsequent to this training, a laboratory evaluation exercise (Exercise 1) was conducted using standard swipe samples prepared for this exercise by the International Atomic Energy Agency (IAEA). The results of Exercise 1 determined that sample contamination was a major factor in the analysis, and a thorough review of laboratory procedures was required to reduce the level of contamination to acceptable levels. Following modification of sample preparation procedures, the laboratories performed Exercise 2, an analysis of a National Institute of Standards and Technology (NIST) Standard Reference Material (SRM) 1547, Peach Leaves. The results of Exercise 2 demonstrated that several laboratories were capable of accurately determining the total uranium and uranium isotopic distribution in the peach leaves. To build on these successes, Exercise 3 was performed using a series of standard swipe samples prepared by the IAEA and distributed to laboratories supporting ABACC and to PNNL and ORNL. The results of Exercise 3 demonstrate that ABACC now has support laboratories in both Argentina and Brazil, which are capable of

  6. Model-based estimation of finite population total in stratified sampling

    African Journals Online (AJOL)

    The work presented in this paper concerns the estimation of finite population total under model – based framework. Nonparametric regression approach as a method of estimating finite population total is explored. The asymptotic properties of the estimators based on nonparametric regression are also developed under ...

  7. Determination of total alpha activity index in samples of radioactive wastes; Determinacion del indice de actividad alfa total en muestras de desechos radiactivos

    Energy Technology Data Exchange (ETDEWEB)

    Galicia C, F. J.

    2015-07-01

    This study aimed to develop a methodology of preparation and quantification of samples containing radionuclides beta and/or alpha emitters, to determine the rates of alpha and beta total activity of radioactive waste samples. For this, a device of planchettes preparer was designed, to assist the planchettes preparation in a controlled environment and free of corrosive vapors. Planchettes were prepared in three means: nitrate, carbonate and sulfate, to different mass thickness, natural uranium (alpha and beta emitter) and in case of Sr-90 (beta emitter pure) only in half nitrate; and these planchettes were quantified in an alpha/beta counter, in order to construct the self-absorption curves for alpha and beta particles. These curves are necessary to determine the rate of alpha-beta activity of any sample because they provide the self-absorption correction factor to be applied in calculating the index. Samples with U were prepared with the help of the device of planchettes preparer and subsequently were analyzed in the proportional counter Mpc-100 Pic brand. Samples with Sr-90 were prepared without the device to see if there was a different behavior with respect to obtaining mass thickness. Similarly they were calcined and carried out count in the Mpc-100. To perform the count, first the parameters of counter operating were determined: operating voltages for alpha and beta particles 630 and 1500 V respectively, a count routine was generated where the time and count type were adjusted, and counting efficiencies for alpha and beta particles, with the aid of calibration sources of {sup 210}Po for alphas and {sup 90}Sr for betas. According to the results, the counts per minute will decrease as increasing the mass thickness of the sample (self-absorption curve), adjusting this behavior to an exponential function in all cases studied. The minor self-absorption of alpha and beta particles in the case of U was obtained in sulfate medium. The self-absorption curves of Sr-90

  8. Metals determination in coffee sample by total reflection X-ray fluorescence analysis (TXRF)

    International Nuclear Information System (INIS)

    Vives, Ana Elisa Sirito de

    2005-01-01

    The objective of this study was to evaluate the inorganic concentration in five brands of coffee, three of them nationally marketed and the others of an exportation kind. The samples were prepared by infusion with deionized water. To carry out the calibration, standard solutions were prepared with different concentrations of Al, Si, K, Ca, Ti, Cr, Fe, Ni, Zn and Se. The measurements were carried out using a white beam of synchrotron radiation for excitation and a Si (Li) semiconductor detector for detection. By employing Synchrotron Radiation Total Reflection X-Ray Fluorescence Analysis (SR-TXRF) it was possible to evaluate the concentrations of P, S, Cl, K, Ca, Mn, Fe, Cu, Zn, Rb and Ba. The detection limits for 300 s counting time were in the range of 0.03 (Ca) to 30 ng.g -1 (Rb), respectively. (author)

  9. Metals determination in coffee sample by total reflection X-ray fluorescence analysis (TXRF)

    Energy Technology Data Exchange (ETDEWEB)

    Vives, Ana Elisa Sirito de [Universidade Metodista de Piracicaba (UNIMEP), Santa Barbara D' Oeste, SP (Brazil). Faculdade de Engenharia, Arquitetura e Urbanismo]. E-mail: aesvives@unimep.br; Moreira, Silvana [Universidade Estadual de Campinas, SP (Brazil). Faculdade de Engenharia Civil, Arquitetura e Urbanismo]. E-mail: Silvana@fec.unicamp.br; Brienza, Sandra Maria Boscolo [ Universidade Metodista de Piracicaba (UNIMEP), Piracicaba, SP (Brazil). Faculdade de Ciencias Matematicas, da Natureza e de Tecnologia da Informacao]. E-mail: sbrienza@unimep.br; Zucchi, Orgheda Luiza Araujo Domingues [Sao Paulo Univ., Ribeirao Preto, SP (Brazil). Faculdade de Ciencias Farmaceuticas]. E-mail: olzucchi@fcfrp.usp.br; Nascimento Filho, Virgilio Franco do [Centro de Energia Nuclear na Agricultura (CENA), Piracicaba, SP (Brazil)]. E-mail: virgilio@cena.usp.br

    2005-07-01

    The objective of this study was to evaluate the inorganic concentration in five brands of coffee, three of them nationally marketed and the others of an exportation kind. The samples were prepared by infusion with deionized water. To carry out the calibration, standard solutions were prepared with different concentrations of Al, Si, K, Ca, Ti, Cr, Fe, Ni, Zn and Se. The measurements were carried out using a white beam of synchrotron radiation for excitation and a Si (Li) semiconductor detector for detection. By employing Synchrotron Radiation Total Reflection X-Ray Fluorescence Analysis (SR-TXRF) it was possible to evaluate the concentrations of P, S, Cl, K, Ca, Mn, Fe, Cu, Zn, Rb and Ba. The detection limits for 300 s counting time were in the range of 0.03 (Ca) to 30 ng.g{sup -1} (Rb), respectively. (author)

  10. Pressure-modulation dynamic attenuated-total-reflectance (ATR) FT-IR spectroscopy

    Science.gov (United States)

    Marcott, C.; Story, G. M.; Noda, I.; Bibby, A.; Manning, C. J.

    1998-06-01

    A single-reflectance attenuated-total-reflectance (ATR) accessory with a diamond internal-reflection element was modified by the addition of a piezoelectric transducer. Initial dynamic pressure-modulation experiments have been performed in the sample compartment of a step-scanning FT-IR spectrometer. A sinusoidal pressure modulation applied to samples of isotactic polypropylene and linear low density polyethylene resulted in dynamic responses which appear to be similar to those observed in previous dynamic 2D IR experiments. Preliminary pressure-modulation dynamic ATR results are also reported for a styrene-butadiene-styrene triblock copolymer. The new method has the advantages that a much wider variety of sample types and geometries can be studied and less sample preparation is required. Dynamic 2D IR experiments carried out by ATR no longer require thin films of large area and sufficient strength to withstand the dynamic strain applied by a rheometer. The ability to obtain dynamic IR spectroscopic information from a wider variety of sample types and thicknesses would greatly expand the amount of useful information that could be extracted from normally complicated, highly overlapped IR spectra.

  11. Determination of calcium, potassium, manganese, iron, copper and zinc levels in representative samples of two onion cultivars using total reflection X-ray fluorescence and ultrasound extraction procedure

    International Nuclear Information System (INIS)

    Alvarez, J.; Marco, L.M.; Arroyo, J.; Greaves, E.D.; Rivas, R.

    2003-01-01

    The chemical characterization of onion cultivar samples is an important tool for the enhancement of their productivity due to the fact that chemical composition is closed related to the quality of the products. A new sample preparation procedure for elemental characterization is proposed, involving the acid extraction of the analytes from crude samples by means of an ultrasonic bath, avoiding the required digestion of samples in vegetable tissue analysis. The technique of total reflection X-ray fluorescence (TXRF) was successfully applied for the simultaneous determination of the elements Ca, K, Mn, Fe, Cu and Zn. The procedure was compared with the wet ashing and dry ashing procedures for all the elements using multivariate analysis and the Scheffe test. The technique of flame atomic absorption spectrometry (FAAS) was employed for comparison purposes and accuracy evaluation of the proposed analysis method. A good agreement between the two techniques was found when using the dry ashing and ultrasound leaching procedures. The levels of each element found for representative samples of two onion cultivars (Yellow Granex PRR 502 and 438 Granex) were also compared by the same method. Levels of K, Mn and Zn were significantly higher in the 438 Granex cultivar, while levels of Ca, Fe and Cu were significantly higher in the Yellow Granex PRR 502 cultivar

  12. Compatibility grab sampling and analysis plan for fiscal year 1999

    International Nuclear Information System (INIS)

    SASAKI, L.M.

    1999-01-01

    This sampling and analysis plan (SAP) identifies characterization objectives pertaining to sample collection, laboratory analytical evaluation, and reporting requirements for grab samples obtained to address waste compatibility. Analytical requirements are taken from two revisions of the Compatibility data quality objectives (DQOs). Revision 1 of the DQO (Fowler 1995) listed analyses to be performed to meet both safety and operational data needs for the Compatibility program. Revision 2A of the DQO (Mulkey and Miller 1998) addresses only the safety-related requirements; the operational requirements of Fowler (1995) have not been superseded by Mulkey and Miller (1998). Therefore, safety-related data needs are taken from Mulkey and Miller (1998) and operational-related data needs are taken from Fowler (1995). Ammonia and total alpha analyses are also performed in accordance with Fowler (1998a, 1998b)

  13. Neuromuscular dose-response studies: determining sample size.

    Science.gov (United States)

    Kopman, A F; Lien, C A; Naguib, M

    2011-02-01

    Investigators planning dose-response studies of neuromuscular blockers have rarely used a priori power analysis to determine the minimal sample size their protocols require. Institutional Review Boards and peer-reviewed journals now generally ask for this information. This study outlines a proposed method for meeting these requirements. The slopes of the dose-response relationships of eight neuromuscular blocking agents were determined using regression analysis. These values were substituted for γ in the Hill equation. When this is done, the coefficient of variation (COV) around the mean value of the ED₅₀ for each drug is easily calculated. Using these values, we performed an a priori one-sample two-tailed t-test of the means to determine the required sample size when the allowable error in the ED₅₀ was varied from ±10-20%. The COV averaged 22% (range 15-27%). We used a COV value of 25% in determining the sample size. If the allowable error in finding the mean ED₅₀ is ±15%, a sample size of 24 is needed to achieve a power of 80%. Increasing 'accuracy' beyond this point requires increasing greater sample sizes (e.g. an 'n' of 37 for a ±12% error). On the basis of the results of this retrospective analysis, a total sample size of not less than 24 subjects should be adequate for determining a neuromuscular blocking drug's clinical potency with a reasonable degree of assurance.

  14. Probabilistic Requirements (Partial) Verification Methods Best Practices Improvement. Variables Acceptance Sampling Calculators: Empirical Testing. Volume 2

    Science.gov (United States)

    Johnson, Kenneth L.; White, K. Preston, Jr.

    2012-01-01

    The NASA Engineering and Safety Center was requested to improve on the Best Practices document produced for the NESC assessment, Verification of Probabilistic Requirements for the Constellation Program, by giving a recommended procedure for using acceptance sampling by variables techniques as an alternative to the potentially resource-intensive acceptance sampling by attributes method given in the document. In this paper, the results of empirical tests intended to assess the accuracy of acceptance sampling plan calculators implemented for six variable distributions are presented.

  15. Air sampling in the workplace to meet the new part 20 requirements

    International Nuclear Information System (INIS)

    McGuire, S.; Hickey, E.E.; Knox, W.

    1991-01-01

    The US Nuclear Regulatory Commission is developing a Regulatory Guide on air sampling in the workplace to meet the requirements of the revised Part 20. The guide will be accompanied by a technical manual describing and giving examples of how to meet the recommendations in the guide. Draft versions of the guide and manual are scheduled to be published for public comment this year. A final guide and manual, revised to consider the public comments, are scheduled to be published in 1992. This talk will summarize some of the more important features of the guide and manual. In particular, the talk will discuss how to demonstrate that samples taken to estimate worker intakes are representative of the air inhaled by workers and what measurements are necessary if a licensee wants to adjust derived air concentrations to account for particle size

  16. Sampling and instrumentation requirements for long-range D and D activities at INEL

    International Nuclear Information System (INIS)

    Ahlquist, A.J.

    1985-01-01

    Assistance was requested to help determine sampling and instrumentation requirements for the long-range decontamination and decommissioning activities at the Idaho National Engineering Laboratory. Through a combination of literature review, visits to other DOE contractors, and a determination of the needs for the INEL program, a draft report has been prepared that is now under review. The final report should be completed in FY 84

  17. Significant increase in cultivation of Gardnerella vaginalis, Alloscardovia omnicolens, Actinotignum schaalii, and Actinomyces spp. in urine samples with total laboratory automation.

    Science.gov (United States)

    Klein, Sabrina; Nurjadi, Dennis; Horner, Susanne; Heeg, Klaus; Zimmermann, Stefan; Burckhardt, Irene

    2018-04-13

    While total laboratory automation (TLA) is well established in laboratory medicine, only a few microbiological laboratories are using TLA systems. Especially in terms of speed and accuracy, working with TLA is expected to be superior to conventional microbiology. We compared in total 35,564 microbiological urine cultures with and without incubation and processing with BD Kiestra TLA for a 6-month period each retrospectively. Sixteen thousand three hundred thirty-eight urine samples were analyzed in the pre-TLA period and 19,226 with TLA. Sixty-two percent (n = 10,101/16338) of the cultures processed without TLA and 68% (n = 13,102/19226) of the cultures processed with TLA showed growth. There were significantly more samples with two or more species per sample and with low numbers of colony forming units (CFU) after incubation with TLA. Regarding the type of bacteria, there were comparable amounts of Enterobacteriaceae in the samples, slightly less non-fermenting Gram-negative bacteria, but significantly more Gram-positive cocci, and Gram-positive rods. Especially Alloscardivia omnicolens, Gardnerella vaginalis, Actinomyces spp., and Actinotignum schaalii were significantly more abundant in the samples incubated and processed with TLA. The time to report was significantly lower in the TLA processed samples by 1.5 h. We provide the first report in Europe of a large number of urine samples processed with TLA. TLA showed enhanced growth of non-classical and rarely cultured bacteria from urine samples. Our findings suggest that previously underestimated bacteria may be relevant pathogens for urinary tract infections. Further studies are needed to confirm our findings.

  18. RANKED SET SAMPLING FOR ECOLOGICAL RESEARCH: ACCOUNTING FOR THE TOTAL COSTS OF SAMPLING

    Science.gov (United States)

    Researchers aim to design environmental studies that optimize precision and allow for generalization of results, while keeping the costs of associated field and laboratory work at a reasonable level. Ranked set sampling is one method to potentially increase precision and reduce ...

  19. Total sulfur determination in gasoline, kerosene and diesel fuel using inductively coupled plasma optical emission spectrometry after direct sample introduction as detergent emulsions

    International Nuclear Information System (INIS)

    Santelli, Ricardo Erthal; Padua Oliveira, Eliane; Batista de Carvalho, Maria de Fatima; Almeida Bezerra, Marcos; Soares Freire, Aline

    2008-01-01

    Herein, we present the development of a procedure for the determination of total sulfur in petroleum-derived products (gasoline, kerosene and diesel fuel) employing inductively coupled plasma optical emission spectrometry (ICP OES). For this procedure, samples were prepared as emulsions that were made using concentrated nitric acid, Triton X-100, sample, and ultra pure water in proportions of 5/10/7/78% (v/v), respectively. Sample volumes were weighed because of the density differences, and oxygen was added to the sheat gas entrance of the ICP OES in order to decrease carbon deposition in the torch and to minimize background effects. A Doehlert design was applied as an experimental matrix to investigate the flow ratios of argon (sheat and plasma gas) and oxygen in relation to the signal-to-background ratio. A comparative study among the slopes of the analytical curves built in aqueous media, surfactant/HNO 3 , and by spike addition for several sample emulsions indicates that a unique solution of surfactant in acidic media can be employed to perform the external calibration for analysis of the emulsions. The developed procedure allows for the determination of the total sulfur content in petroleum derivatives with a limit of detection (LOD) and limit of quantification (LOQ) of 0.72 and 2.4 μg g -1 , respectively. Precision values, expressed as the relative standard deviations (% RSD, n = 10) for 12 and 400 μg g -1 , were 2.2% and 1.3%, respectively. The proposed procedure was applied toward the determination of total sulfur in samples of gasoline, kerosene, and diesel fuel commercialized in the city of Niteroi/RJ, Brazil. The accuracy of the proposed method was evaluated by the determination of the total sulfur in three different standard reference materials (SRM): NIST 2723a (sulfur in diesel fuel oil), NIST 1616b (sulfur in kerosene), and NIST 2298 (sulfur in gasoline). The data indicate that the methodology can be successfully applied to these types of samples

  20. 40 CFR 80.583 - What alternative sampling and testing requirements apply to importers who transport motor vehicle...

    Science.gov (United States)

    2010-07-01

    ... requirements apply to importers who transport motor vehicle diesel fuel, NRLM diesel fuel, or ECA marine fuel... (CONTINUED) AIR PROGRAMS (CONTINUED) REGULATION OF FUELS AND FUEL ADDITIVES Motor Vehicle Diesel Fuel... alternative sampling and testing requirements apply to importers who transport motor vehicle diesel fuel, NRLM...

  1. Data Quality Objectives for Regulatory Requirements for Hazardous and Radioactive Air Emissions Sampling and Analysis

    Energy Technology Data Exchange (ETDEWEB)

    MULKEY, C.H.

    1999-07-06

    This document describes the results of the data quality objective (DQO) process undertaken to define data needs for state and federal requirements associated with toxic, hazardous, and/or radiological air emissions under the jurisdiction of the River Protection Project (RPP). Hereafter, this document is referred to as the Air DQO. The primary drivers for characterization under this DQO are the regulatory requirements pursuant to Washington State regulations, that may require sampling and analysis. The federal regulations concerning air emissions are incorporated into the Washington State regulations. Data needs exist for nonradioactive and radioactive waste constituents and characteristics as identified through the DQO process described in this document. The purpose is to identify current data needs for complying with regulatory drivers for the measurement of air emissions from RPP facilities in support of air permitting. These drivers include best management practices; similar analyses may have more than one regulatory driver. This document should not be used for determining overall compliance with regulations because the regulations are in constant change, and this document may not reflect the latest regulatory requirements. Regulatory requirements are also expected to change as various permits are issued. Data needs require samples for both radionuclides and nonradionuclide analytes of air emissions from tanks and stored waste containers. The collection of data is to support environmental permitting and compliance, not for health and safety issues. This document does not address health or safety regulations or requirements (those of the Occupational Safety and Health Administration or the National Institute of Occupational Safety and Health) or continuous emission monitoring systems. This DQO is applicable to all equipment, facilities, and operations under the jurisdiction of RPP that emit or have the potential to emit regulated air pollutants.

  2. Data Quality Objectives for Regulatory Requirements for Hazardous and Radioactive Air Emissions Sampling and Analysis

    International Nuclear Information System (INIS)

    MULKEY, C.H.

    1999-01-01

    This document describes the results of the data quality objective (DQO) process undertaken to define data needs for state and federal requirements associated with toxic, hazardous, and/or radiological air emissions under the jurisdiction of the River Protection Project (RPP). Hereafter, this document is referred to as the Air DQO. The primary drivers for characterization under this DQO are the regulatory requirements pursuant to Washington State regulations, that may require sampling and analysis. The federal regulations concerning air emissions are incorporated into the Washington State regulations. Data needs exist for nonradioactive and radioactive waste constituents and characteristics as identified through the DQO process described in this document. The purpose is to identify current data needs for complying with regulatory drivers for the measurement of air emissions from RPP facilities in support of air permitting. These drivers include best management practices; similar analyses may have more than one regulatory driver. This document should not be used for determining overall compliance with regulations because the regulations are in constant change, and this document may not reflect the latest regulatory requirements. Regulatory requirements are also expected to change as various permits are issued. Data needs require samples for both radionuclides and nonradionuclide analytes of air emissions from tanks and stored waste containers. The collection of data is to support environmental permitting and compliance, not for health and safety issues. This document does not address health or safety regulations or requirements (those of the Occupational Safety and Health Administration or the National Institute of Occupational Safety and Health) or continuous emission monitoring systems. This DQO is applicable to all equipment, facilities, and operations under the jurisdiction of RPP that emit or have the potential to emit regulated air pollutants

  3. INVESTIGATION OF THE TOTAL ORGANIC HALOGEN ANALYTICAL METHOD AT THE WASTE SAMPLING CHARACTERIZATION FACILITY (WSCF)

    International Nuclear Information System (INIS)

    DOUGLAS JG; MEZNARICH HD, PHD; OLSEN JR; ROSS GA; STAUFFER M

    2008-01-01

    Total organic halogen (TOX) is used as a parameter to screen groundwater samples at the Hanford Site. Trending is done for each groundwater well, and changes in TOX and other screening parameters can lead to costly changes in the monitoring protocol. The Waste Sampling and Characterization Facility (WSCF) analyzes groundwater samples for TOX using the United States Environmental Protection Agency (EPA) SW-846 method 9020B (EPA 1996a). Samples from the Soil and Groundwater Remediation Project (S and GRP) are submitted to the WSCF for analysis without information regarding the source of the sample; each sample is in essence a 'blind' sample to the laboratory. Feedback from the S and GRP indicated that some of the WSCF-generated TOX data from groundwater wells had a number of outlier values based on the historical trends (Anastos 2008a). Additionally, analysts at WSCF observed inconsistent TOX results among field sample replicates. Therefore, the WSCF lab performed an investigation of the TOX analysis to determine the cause of the outlier data points. Two causes were found that contributed to generating out-of-trend TOX data: (1) The presence of inorganic chloride in the groundwater samples: at inorganic chloride concentrations greater than about 10 parts per million (ppm), apparent TOX values increase with increasing chloride concentration. A parallel observation is the increase in apparent breakthrough of TOX from the first to the second activated-carbon adsorption tubes with increasing inorganic chloride concentration. (2) During the sample preparation step, excessive purging of the adsorption tubes with oxygen pressurization gas after sample loading may cause channeling in the activated-carbon bed. This channeling leads to poor removal of inorganic chloride during the subsequent wash step with aqueous potassium nitrate. The presence of this residual inorganic chloride then produces erroneously high TOX values. Changes in sample preparation were studied to more

  4. INVESTIGATION OF THE TOTAL ORGANIC HALOGEN ANALYTICAL METHOD AT THE WASTE SAMPLING AND CHARACTERIZATION FACILITY

    International Nuclear Information System (INIS)

    Douglas, J.G.; Meznarich, H.K.; Olsen, J.R.; Ross, G.A.; Stauffer, M.

    2009-01-01

    Total organic halogen (TOX) is used as a parameter to screen groundwater samples at the Hanford Site. Trending is done for each groundwater well, and changes in TOX and other screening parameters can lead to costly changes in the monitoring protocol. The Waste Sampling and Characterization Facility (WSCF) analyzes groundwater samples for TOX using the United States Environmental Protection Agency (EPA) SW-S46 method 9020B (EPA 1996a). Samples from the Soil and Groundwater Remediation Project (SGRP) are submitted to the WSCF for analysis without information regarding the source of the sample; each sample is in essence a ''blind'' sample to the laboratory. Feedback from the SGRP indicated that some of the WSCF-generated TOX data from groundwater wells had a number of outlier values based on the historical trends (Anastos 200Sa). Additionally, analysts at WSCF observed inconsistent TOX results among field sample replicates. Therefore, the WSCF lab performed an investigation of the TOX analysis to determine the cause of the outlier data points. Two causes were found that contributed to generating out-of-trend TOX data: (1) The presence of inorganic chloride in the groundwater samples: at inorganic chloride concentrations greater than about 10 parts per million (ppm), apparent TOX values increase with increasing chloride concentration. A parallel observation is the increase in apparent breakthrough of TOX from the first to the second activated-carbon adsorption tubes with increasing inorganic chloride concentration. (2) During the sample preparation step, excessive purging of the adsorption tubes with oxygen pressurization gas after sample loading may cause channeling in the activated carbon bed. This channeling leads to poor removal of inorganic chloride during the subsequent wash step with aqueous potassium nitrate. The presence of this residual inorganic chloride then produces erroneously high TOX values. Changes in sample preparation were studied to more effectively

  5. Urine sample collection protocols for bioassay samples

    Energy Technology Data Exchange (ETDEWEB)

    MacLellan, J.A.; McFadden, K.M.

    1992-11-01

    In vitro radiobioassay analyses are used to measure the amount of radioactive material excreted by personnel exposed to the potential intake of radioactive material. The analytical results are then used with various metabolic models to estimate the amount of radioactive material in the subject`s body and the original intake of radioactive material. Proper application of these metabolic models requires knowledge of the excretion period. It is normal practice to design the bioassay program based on a 24-hour excretion sample. The Hanford bioassay program simulates a total 24-hour urine excretion sample with urine collection periods lasting from one-half hour before retiring to one-half hour after rising on two consecutive days. Urine passed during the specified periods is collected in three 1-L bottles. Because the daily excretion volume given in Publication 23 of the International Commission on Radiological Protection (ICRP 1975, p. 354) for Reference Man is 1.4 L, it was proposed to use only two 1-L bottles as a cost-saving measure. This raised the broader question of what should be the design capacity of a 24-hour urine sample kit.

  6. Urine sample collection protocols for bioassay samples

    Energy Technology Data Exchange (ETDEWEB)

    MacLellan, J.A.; McFadden, K.M.

    1992-11-01

    In vitro radiobioassay analyses are used to measure the amount of radioactive material excreted by personnel exposed to the potential intake of radioactive material. The analytical results are then used with various metabolic models to estimate the amount of radioactive material in the subject's body and the original intake of radioactive material. Proper application of these metabolic models requires knowledge of the excretion period. It is normal practice to design the bioassay program based on a 24-hour excretion sample. The Hanford bioassay program simulates a total 24-hour urine excretion sample with urine collection periods lasting from one-half hour before retiring to one-half hour after rising on two consecutive days. Urine passed during the specified periods is collected in three 1-L bottles. Because the daily excretion volume given in Publication 23 of the International Commission on Radiological Protection (ICRP 1975, p. 354) for Reference Man is 1.4 L, it was proposed to use only two 1-L bottles as a cost-saving measure. This raised the broader question of what should be the design capacity of a 24-hour urine sample kit.

  7. Calibration samples for accelerator mass spectrometry

    International Nuclear Information System (INIS)

    Hershberger, R.L.; Flynn, D.S.; Gabbard, F.

    1981-01-01

    Radioactive samples with precisely known numbers of atoms are useful as calibration sources for lifetime measurements using accelerator mass spectrometry. Such samples can be obtained in two ways: either by measuring the production rate as the sample is created or by measuring the decay rate after the sample has been obtained. The latter method requires that a large sample be produced and that the decay constant be accurately known. The former method is a useful and independent alternative, especially when the decay constant is not well known. The facilities at the University of Kentucky for precision measurements of total neutron production cross sections offer a source of such calibration samples. The possibilities, while quite extensive, would be limited to the proton rich side of the line of stability because of the use of (p,n) and (α,n) reactions for sample production

  8. Trace element analysis of mineral and tap water samples using total reflection x-ray fluorescence (TXRF)

    International Nuclear Information System (INIS)

    Mangala, M.J.; Korir, K.A.; Maina, D.M.; Kinyua, A.M.

    2000-01-01

    Results of trace element analysis by TXRF of tap water and various brands of bottled mineral water samples which are representative of local and imported brands sold in Nairobi are reported. The variation in elemental concentrations in water samples analyzed were as follows: potassium (K) 0.2 to 28.9 μg/ml; calcium (Ca) 2.2 to 120 μg/ml; titanium (Ti) 11 to 60 μg/l; manganese (Mn) 8 to 670 μg/l; iron (Fe) 31 to 540 μg/l; copper (Cu) 8 to 30 μg/l; zinc (Zn) 8 to 4730 μg/l; bromine (Br) 9 to 248 μg/l; rubidium (Rb) 10 to 40 μg/l and strontium (Sr) 10 to 1000 μg/l. Local mineral water samples contain higher levels of trace elements; manganese (Mn), zinc (Zn), bromine (Br), rubidium (Rb) and strontium (Sr) as compared to the imported brands. Principal component analysis of the results revealed three component loading factors clusters for: rubidium (Rb), strontium (Sr) and calcium (Ca); titanium (Ti), iron (Fe), bromine (Br), and zinc (Zn); zinc (Zn), manganese (Mn) and potassium (K) respectively. The percentage of total variance explained by the components was 31.4, 27.3, and 14.8 respectively. In this study, we also found that a limited spread of 5-6 mm for a 10 μl sample was achieved when the quartz sample carrier was dried in a low pressure (300 mbar) oven at 70 o C for 10 hours. (author)

  9. Sampling from the normal and exponential distributions

    International Nuclear Information System (INIS)

    Chaplin, K.R.; Wills, C.A.

    1982-01-01

    Methods for generating random numbers from the normal and exponential distributions are described. These involve dividing each function into subregions, and for each of these developing a method of sampling usually based on an acceptance rejection technique. When sampling from the normal or exponential distribution, each subregion provides the required random value with probability equal to the ratio of its area to the total area. Procedures written in FORTRAN for the CYBER 175/CDC 6600 system are provided to implement the two algorithms

  10. Passive Dosing to Determine the Speciation of Hydrophobic Organic Chemicals in Aqueous Samples

    DEFF Research Database (Denmark)

    Birch, Heidi; Gouliarmou, V.; Lützhøft, Hans-Christian Holten

    2010-01-01

    A new analytical approach to determine the speciation of hydrophobic organic analytes is presented. The freely dissolved concentration in a sample is controlled by passive dosing from silicone (poly(dimethylsiloxane)), and the total sample concentration at equilibrium is measured. The free fraction...... is determined as the ratio between measured concentrations in pure water and sample. C-14-labeled fluoranthene served as model analyte, and total sample concentrations were easily measured by liquid scintillation counting. The method was applied to surface water, stormwater runoff, and wastewater...... (SPME). This analytical approach combines simplicity with high precision, and it does not require any phase separation steps....

  11. Determination of total sulfur in agricultural samples by high-resolution continuum source flame molecular absorption spectrometry.

    Science.gov (United States)

    Virgilio, Alex; Raposo, Jorge L; Cardoso, Arnaldo A; Nóbrega, Joaquim A; Gomes Neto, José A

    2011-03-23

    The usefulness of molecular absorption was investigated for the determination of total sulfur (S) in agricultural samples by high-resolution continuum source flame molecular absorption spectrometry. The lines for CS at 257.595, 257.958, and 258.056 nm and for SH at 323.658, 324.064, and 327.990 nm were evaluated. Figures of merit, such as linear dynamic range, sensitivity, linear correlation, characteristic concentration, limit of detection, and precision, were established. For selected CS lines, wavelength-integrated absorbance equivalent to 3 pixels, analytical curves in the 100-2500 mg L(-1) (257.595 nm), 250-2000 mg L(-1) (257.958 nm), and 250-5000 mg L(-1) (258.056 nm) ranges with a linear correlation coefficient better than 0.9980 were obtained. Results were in agreement at a 95% confidence level (paired t test) with those obtained by gravimetry. Recoveries of S in fungicide and fertilizer samples were within the 84-109% range, and the relative standard deviation (n=12) was typically <5%.

  12. Concentrations of bisphenol A in the composite food samples from the 2008 Canadian total diet study in Quebec City and dietary intake estimates.

    Science.gov (United States)

    Cao, X-L; Perez-Locas, C; Dufresne, G; Clement, G; Popovic, S; Beraldin, F; Dabeka, R W; Feeley, M

    2011-06-01

    A total of 154 food composite samples from the 2008 total diet study in Quebec City were analysed for bisphenol A (BPA), and BPA was detected in less than half (36%, or 55 samples) of the samples tested. High concentrations of BPA were found mostly in the composite samples containing canned foods, with the highest BPA level being observed in canned fish (106 ng g(-1)), followed by canned corn (83.7 ng g(-1)), canned soups (22.2-44.4 ng g(-1)), canned baked beans (23.5 ng g(-1)), canned peas (16.8 ng g(-1)), canned evaporated milk (15.3 ng g(-1)), and canned luncheon meats (10.5 ng g(-1)). BPA levels in baby food composite samples were low, with 2.75 ng g(-1) in canned liquid infant formula, and 0.84-2.46 ng g(-1) in jarred baby foods. BPA was also detected in some foods that are not canned or in jars, such as yeast (8.52 ng g(-1)), baking powder (0.64 ng g(-1)), some cheeses (0.68-2.24 ng g(-1)), breads and some cereals (0.40-1.73 ng g(-1)), and fast foods (1.1-10.9 ng g(-1)). Dietary intakes of BPA were low for all age-sex groups, with 0.17-0.33 µg kg(-1) body weight day(-1) for infants, 0.082-0.23 µg kg(-1) body weight day(-1) for children aged from 1 to 19 years, and 0.052-0.081 µg kg(-1) body weight day(-1) for adults, well below the established regulatory limits. BPA intakes from 19 of the 55 samples account for more than 95% of the total dietary intakes, and most of the 19 samples were either canned or in jars. Intakes of BPA from non-canned foods are low.

  13. Value of a simple technique for the measurement of total renal function and each kidney functions without requiring blood or urine samples

    International Nuclear Information System (INIS)

    Meyers, A.; Chachati, A.; Godon, J.P.; Rigo, P.

    1985-01-01

    The determination of renal uptake of 99m Tc DTPA and of 131 I Hippuran (as a percentage of the administred dose) at a time interval 1-3 minutes after tracer injection, is a rapid, accurate method for the measurement of total renal function and each kidney functions. Its clinical validity has been confirmed [fr

  14. Total Sulfur Amino Acid Requirements Are Not Altered in Children with Chronic Renal Insufficiency, but Minimum Methionine Needs Are Increased.

    Science.gov (United States)

    Elango, Rajavel; Humayun, Mohammad A; Turner, Justine M; Rafii, Mahroukh; Langos, Veronika; Ball, Ronald O; Pencharz, Paul B

    2017-10-01

    Background: The total sulfur amino acid (TSAA) and minimum Met requirements have been previously determined in healthy children. TSAA metabolism is altered in kidney disease. Whether TSAA requirements are altered in children with chronic renal insufficiency (CRI) is unknown. Objective: We sought to determine the TSAA (Met in the absence of Cys) requirements and minimum Met (in the presence of excess Cys) requirements in children with CRI. Methods: Five children (4 boys, 1 girl) aged 10 ± 2.6 y with CRI were randomly assigned to receive graded intakes of Met (0, 5, 10, 15, 25, and 35 mg · kg -1 · d -1 ) with no Cys in the diet. Four of the children (3 boys, 1 girl) were then randomly assigned to receive graded dietary intakes of Met (0, 2.5, 5, 7.5, 10, and 15 mg · kg -1 · d -1 ) with 21 mg · kg -1 · d -1 Cys. The mean TSAA and minimum Met requirements were determined by measuring the oxidation of l-[1- 13 C]Phe to 13 CO 2 (F 13 CO 2 ). A 2-phase linear-regression crossover analysis of the F 13 CO 2 data identified a breakpoint at minimal F 13 CO 2 Urine samples collected from all study days and from previous studies of healthy children were measured for sulfur metabolites. Results: The mean and population-safe (upper 95% CI) intakes of TSAA and minimum Met in children with CRI were determined to be 12.6 and 15.9 mg · kg -1 · d -1 and 7.3 and 10.9 mg · kg -1 · d -1 , respectively. In healthy school-aged children the mean and upper 95% CI intakes of TSAA and minimum Met were determined to be 12.9 and 17.2 mg · kg -1 · d -1 and 5.8 and 7.3 mg · kg -1 · d -1 , respectively. A comparison of the minimum Met requirements between healthy children and children with CRI indicated significant ( P < 0.05) differences. Conclusion: These results suggest that children with CRI have a similar mean and population-safe TSAA to that of healthy children, suggesting adequate Cys synthesis via transsulfuration, but higher minimum Met requirement, suggesting reduced

  15. [Intra-Articular Application of Tranexamic Acid Significantly Reduces Blood Loss and Transfusion Requirement in Primary Total Knee Arthroplasty].

    Science.gov (United States)

    Lošťák, J; Gallo, J; Špička, J; Langová, K

    2016-01-01

    PURPOSE OF THE STUDY The aim of this prospective study was to investigate the effect of topical application of tranexamic acid (TXA, Exacyl) on the amount of post-operative blood loss, and blood transfusion requirement in patients undergoing primary total knee arthroplasty (TKA). Attention was paid to early complications potentially associated with TXA administration, such as haematoma, wound exudate, or knee swelling. In addition, the economic benefit of TXA treatment was also taken into account. MATERIAL AND METHODS The study included 238 patients (85 men and 153 women) who underwent primary total knee arthroplasty (TKA) at our department between January 2013 and November 2015. A group of 119 patients (41 men and 78 women) received intraarticular TXA injections according to the treatment protocol (TXA group). A control group matched in basic characteristics to the TXA group also consisted of 119 patients. The average age in the TXA group was 69.8 years, and the most frequent indication for TKA surgery was primary knee osteoarthritis (81.5%). In each patient, post-operative volume of blood lost from drains and total blood loss including hidden blood loss were recorded, as well as post-operative haemoglobin and haematocrit levels. On discharge of each patient from hospital, the size and site of a haematoma; wound exudate, if present after post-operative day 4; joint swelling; range of motion and early revision surgery, if performed, were evaluated. Requirements of analgesic drugs after surgery were also recorded. RESULTS In the TXA group, blood losses from drains were significantly lower than in the control group (456.7 ± 270.8 vs 640.5 ±448.2; p = 0.004). The median value for blood losses from drains was lower by 22% and the average value for total blood loss, including hidden losses, was also lower than in the control group (762.4 ± 345.2 ml vs 995.5 ± 457.3 ml). The difference in the total amount of blood loss between the two groups was significant (p = 0

  16. Use of total body electrical conductivity (TOBEC) to determine total body water

    International Nuclear Information System (INIS)

    Cochran, W.; Wong, W.; Sheng, H.P.; Klein, P.; Klish, W.

    1986-01-01

    Total body electrical conductivity (TOBEC) has been introduced as a safe and rapid method to estimate body composition in infants and adults. Recently, a second generation instrument that operates in a scanning mode has been developed. A study was undertaken to calibrate this new instrument and to assess the feasibility of its use in estimating total body water. Six healthy adults, 3 males and 3 females, ranging in age from 25 to 57 years, and in weight from 43.3 to 104.7 kg were analyzed. Simultaneously, determinations of total body water were made by standard dilutional techniques using H 2 18 O. A baseline plasma sample was obtained and 60 mg 18 O/kg was given orally as H 2 18 O. Five hr later, a postdose plasma sample was obtained. The 18 O/ 16 O ratio in the plasma samples was determined as CO 2 by gas-isotope-ratio mass spectrometry and used to calculate the H 2 18 O volume of distribution. The total body water values ranged from 26.35 to 58.02 and represented 51 to 58% of body weight. There was good linear correlation between the total body water measurement and its phase average (TOBEC number) with a linear correlation coefficient of 0.998. The standard error of the estimate was 0.98. In addition to estimating fat and fat-free mass, the TOBEC method also estimates total body water with excellent correlation to physical dilutions methods

  17. Cy5 total protein normalization in Western blot analysis.

    Science.gov (United States)

    Hagner-McWhirter, Åsa; Laurin, Ylva; Larsson, Anita; Bjerneld, Erik J; Rönn, Ola

    2015-10-01

    Western blotting is a widely used method for analyzing specific target proteins in complex protein samples. Housekeeping proteins are often used for normalization to correct for uneven sample loads, but these require careful validation since expression levels may vary with cell type and treatment. We present a new, more reliable method for normalization using Cy5-prelabeled total protein as a loading control. We used a prelabeling protocol based on Cy5 N-hydroxysuccinimide ester labeling that produces a linear signal response. We obtained a low coefficient of variation (CV) of 7% between the ratio of extracellular signal-regulated kinase (ERK1/2) target to Cy5 total protein control signals over the whole loading range from 2.5 to 20.0μg of Chinese hamster ovary cell lysate protein. Corresponding experiments using actin or tubulin as controls for normalization resulted in CVs of 13 and 18%, respectively. Glyceraldehyde-3-phosphate dehydrogenase did not produce a proportional signal and was not suitable for normalization in these cells. A comparison of ERK1/2 signals from labeled and unlabeled samples showed that Cy5 prelabeling did not affect antibody binding. By using total protein normalization we analyzed PP2A and Smad2/3 levels with high confidence. Copyright © 2015 Elsevier Inc. All rights reserved.

  18. A novel solid phase extraction procedure on Amberlite XAD-1180 for speciation of Cr(III), Cr(VI) and total chromium in environmental and pharmaceutical samples

    International Nuclear Information System (INIS)

    Narin, Ibrahim; Kars, Ayse; Soylak, Mustafa

    2008-01-01

    Due to the toxicity of chromium, species depend on their chemical properties and bioavailabilities, speciation of chromium is very important in environmental samples. A speciation procedure for chromium(III), chromium(VI) and total chromium in environmental samples is presented in this work, prior to flame atomic absorption spectrometric determination of chromium. The procedure is based on the adsorption of Cr(III)-diphenylcarbazone complex on Amberlite XAD-1180 resin. After oxidation of Cr(III), the developed solid phase extraction system was applied to determinate the total chromium. Cr(III) was calculated as the difference between the total Cr content and the Cr(VI) content. The analytical conditions for the quantitative recoveries of Cr(VI) on Amberlite XAD-1180 resin were investigated. The effects of some alkaline, earth alkaline, metal ions and also some anions were also examined. Preconcentration factor was found to be 75. The detection limits (LOD) based on three times sigma of the blank (N: 21) for Cr(VI) and total chromium were 7.7 and 8.6 μg/L, respectively. Satisfactory results for the analysis of total chromium in the stream sediment (GBW7310) certified reference material for the validation of the presented method was obtained. The procedure was applied to food, water and pharmaceutical samples successfully

  19. Evaluation the total exposure of soil sample in Adaya site and the obtain risk assessments for the worker by Res Rad code program

    International Nuclear Information System (INIS)

    Mahadi, A. M.; Khadim, A. A. N.; Ibrahim, Z. H.; Ali, S. A.

    2012-12-01

    The present study aims to evaluation the total exposure to the worker in Adaya site risk assessment by using Res Rad code program. The study including 5 areas soil sample calculate in the site and analysis it by High Pure Germaniums (Hg) system made (CANBERRA) company. The soil sample simulation by (Res Rad) code program by inter the radioactive isotope concentration and the specification of the contamination zone area, depth and the cover depth of it. The total exposure of same sample was about 9 mSv/year and the (Heast 2001 Morbidity, FGR13 Morbidity) about 2.045 state every 100 worker in the year. There are simple different between Heast 2001 Morbidity and FGR13 Morbidity according to the Dose Conversion Factor (DCF) use it. The (FGR13 Morbidity) about 2.041 state every 100 worker in the year. (Author)

  20. Tracer measured substrate turnover requires arterial sampling downstream of infusion site

    International Nuclear Information System (INIS)

    Stanley, W.C.; Neese, R.A.; Gertz, E.W.; Wisneski, J.A.; Morris, D.L.; Brooks, G.A.

    1986-01-01

    Measurement of metabolite turnover (Rt) with radioactive tracers is done by either infusing tracer venously and sampling specific activity (SA) arterially (V-A modes), or by infusing into the aorta and sampling venous blood (A-V mode). Using the Fick principle, the necessity for using the V-A mode can be demonstrated. If tracer is infused into the left ventricle, in a steady state the Rt is the product of arterial trace concentration, the cardiac output, and the tracer extraction ratio for the whole body. This is expressed as: Rt = Ca x Qx ((*Ca - *Cv)/*Ca) (Eq1) where C=trace concentration (μmol/ml), *C=tracer conc. (dpm/ml), a=arterial, v-=mixed venous, and Q=cardiac output (ml/min). Rearranging the equation: Rt = Qx(*Ca - *Cv)/SAa = F/SAa (Eq2) where SAa is *Ca/Ca, and Qx (*Ca-*Cv) equals the infusion rate (F). The authors compared Eqs1 and 2 (Rt = F/SAa) in 3 anesthetized dogs in which [1- 14 C] lactate was infused into the left ventricle, and blood was sampled arterially downstream from the infusion site and in the pulmonary artery. Eqs 1 and 2 gave similar results for Rt (45.9 vs. 43.9 μmol/kg min), while substituting SAv for SAa (A-V mode) into Eq 2 gave a higher Rt (53.6). When SAv (A-V mode) is used, the specific activity seen by the tissues (SAa) is not considered in the calculation of Rt. Therefore, only the V-A mode meets the requirements for tracer measured metabolite turnover

  1. 40 CFR 1065.595 - PM sample post-conditioning and total weighing.

    Science.gov (United States)

    2010-07-01

    ... minutes before weighing. Note that 400 µg on sample media (e.g., filters) is an approximate net mass of 0... the procedures in § 1065.590(f) through (i) to determine post-test mass of the sample media (e.g., filters). (g) Subtract each buoyancy-corrected tare mass of the sample medium (e.g., filter) from its...

  2. Data Quality Objectives for Regulatory Requirements for Hazardous and Radioactive Air Emissions Sampling and Analysis; FINAL

    International Nuclear Information System (INIS)

    MULKEY, C.H.

    1999-01-01

    This document describes the results of the data quality objective (DQO) process undertaken to define data needs for state and federal requirements associated with toxic, hazardous, and/or radiological air emissions under the jurisdiction of the River Protection Project (RPP). Hereafter, this document is referred to as the Air DQO. The primary drivers for characterization under this DQO are the regulatory requirements pursuant to Washington State regulations, that may require sampling and analysis. The federal regulations concerning air emissions are incorporated into the Washington State regulations. Data needs exist for nonradioactive and radioactive waste constituents and characteristics as identified through the DQO process described in this document. The purpose is to identify current data needs for complying with regulatory drivers for the measurement of air emissions from RPP facilities in support of air permitting. These drivers include best management practices; similar analyses may have more than one regulatory driver. This document should not be used for determining overall compliance with regulations because the regulations are in constant change, and this document may not reflect the latest regulatory requirements. Regulatory requirements are also expected to change as various permits are issued. Data needs require samples for both radionuclides and nonradionuclide analytes of air emissions from tanks and stored waste containers. The collection of data is to support environmental permitting and compliance, not for health and safety issues. This document does not address health or safety regulations or requirements (those of the Occupational Safety and Health Administration or the National Institute of Occupational Safety and Health) or continuous emission monitoring systems. This DQO is applicable to all equipment, facilities, and operations under the jurisdiction of RPP that emit or have the potential to emit regulated air pollutants

  3. Analysis of bioethanol samples through Inductively Coupled Plasma Mass Spectrometry with a total sample consumption system

    Science.gov (United States)

    Sánchez, Carlos; Lienemann, Charles-Philippe; Todolí, Jose-Luis

    2016-10-01

    Bioethanol real samples have been directly analyzed through ICP-MS by means of the so called High Temperature Torch Integrated Sample Introduction System (hTISIS). Because bioethanol samples may contain water, experiments have been carried out in order to determine the effect of ethanol concentration on the ICP-MS response. The ethanol content studied went from 0 to 50%, because higher alcohol concentrations led to carbon deposits on the ICP-MS interface. The spectrometer default spray chamber (double pass) equipped with a glass concentric pneumatic micronebulizer has been taken as the reference system. Two flow regimes have been evaluated: continuous sample aspiration at 25 μL min- 1 and 5 μL air-segmented sample injection. hTISIS temperature has been shown to be critical, in fact ICP-MS sensitivity increased with this variable up to 100-200 °C depending on the solution tested. Higher chamber temperatures led to either a drop in signal or a plateau. Compared with the reference system, the hTISIS improved the sensitivities by a factor included within the 4 to 8 range while average detection limits were 6 times lower for the latter device. Regarding the influence of the ethanol concentration on sensitivity, it has been observed that an increase in the temperature was not enough to eliminate the interferences. It was also necessary to modify the torch position with respect to the ICP-MS interface to overcome them. This fact was likely due to the different extent of ion plasma radial diffusion encountered as a function of the matrix when working at high chamber temperatures. When the torch was moved 1 mm plasma down axis, ethanolic and aqueous solutions provided statistically equal sensitivities. A preconcentration procedure has been applied in order to validate the methodology. It has been found that, under optimum conditions from the point of view of matrix effects, recoveries for spiked samples were close to 100%. Furthermore, analytical concentrations for real

  4. Measuring Blood Glucose Concentrations in Photometric Glucometers Requiring Very Small Sample Volumes.

    Science.gov (United States)

    Demitri, Nevine; Zoubir, Abdelhak M

    2017-01-01

    Glucometers present an important self-monitoring tool for diabetes patients and, therefore, must exhibit high accuracy as well as good usability features. Based on an invasive photometric measurement principle that drastically reduces the volume of the blood sample needed from the patient, we present a framework that is capable of dealing with small blood samples, while maintaining the required accuracy. The framework consists of two major parts: 1) image segmentation; and 2) convergence detection. Step 1 is based on iterative mode-seeking methods to estimate the intensity value of the region of interest. We present several variations of these methods and give theoretical proofs of their convergence. Our approach is able to deal with changes in the number and position of clusters without any prior knowledge. Furthermore, we propose a method based on sparse approximation to decrease the computational load, while maintaining accuracy. Step 2 is achieved by employing temporal tracking and prediction, herewith decreasing the measurement time, and, thus, improving usability. Our framework is tested on several real datasets with different characteristics. We show that we are able to estimate the underlying glucose concentration from much smaller blood samples than is currently state of the art with sufficient accuracy according to the most recent ISO standards and reduce measurement time significantly compared to state-of-the-art methods.

  5. Feedback Blunting: Total Sleep Deprivation Impairs Decision Making that Requires Updating Based on Feedback.

    Science.gov (United States)

    Whitney, Paul; Hinson, John M; Jackson, Melinda L; Van Dongen, Hans P A

    2015-05-01

    To better understand the sometimes catastrophic effects of sleep loss on naturalistic decision making, we investigated effects of sleep deprivation on decision making in a reversal learning paradigm requiring acquisition and updating of information based on outcome feedback. Subjects were randomized to a sleep deprivation or control condition, with performance testing at baseline, after 2 nights of total sleep deprivation (or rested control), and following 2 nights of recovery sleep. Subjects performed a decision task involving initial learning of go and no go response sets followed by unannounced reversal of contingencies, requiring use of outcome feedback for decisions. A working memory scanning task and psychomotor vigilance test were also administered. Six consecutive days and nights in a controlled laboratory environment with continuous behavioral monitoring. Twenty-six subjects (22-40 y of age; 10 women). Thirteen subjects were randomized to a 62-h total sleep deprivation condition; the others were controls. Unlike controls, sleep deprived subjects had difficulty with initial learning of go and no go stimuli sets and had profound impairment adapting to reversal. Skin conductance responses to outcome feedback were diminished, indicating blunted affective reactions to feedback accompanying sleep deprivation. Working memory scanning performance was not significantly affected by sleep deprivation. And although sleep deprived subjects showed expected attentional lapses, these could not account for impairments in reversal learning decision making. Sleep deprivation is particularly problematic for decision making involving uncertainty and unexpected change. Blunted reactions to feedback while sleep deprived underlie failures to adapt to uncertainty and changing contingencies. Thus, an error may register, but with diminished effect because of reduced affective valence of the feedback or because the feedback is not cognitively bound with the choice. This has important

  6. Sampling for radionuclides and other trace substances

    International Nuclear Information System (INIS)

    Eberhardt, L.L.

    1976-01-01

    Various problems with the environment and an energy crisis have resulted in considerable emphasis on the analysis and understanding of natural systems. The present generation of ecological models suffers greatly from a lack of attention to use of accurate and efficient sampling methods in obtaining the data on which these models are based. Improving ecological sampling requires first of all that the objectives be clearly defined, since different schemes are required for sampling for totals, for changes over time and space, to determine hazards, or for estimating parameters in models. The frequency distributions of most ecological contaminants are not normal, but seem instead to follow a skewed distribution. Coefficients of variation appear to be relatively constant and typical values may range from 0.1 to 1.0 depending on the substance and circumstances. These typical values may be very useful in designing a sampling plan, either for fixed relative variance, or in terms of the sensitivity of a comparison. Several classes of sampling methods are available for particular kinds of objectives. The notion of optimal sampling for parameter estimates is new to ecology, but may possibly be adapted from work done in industrial experimentation to provide a rationale for sampling in time

  7. Total laboratory automation: Do stat tests still matter?

    Science.gov (United States)

    Dolci, Alberto; Giavarina, Davide; Pasqualetti, Sara; Szőke, Dominika; Panteghini, Mauro

    2017-07-01

    During the past decades the healthcare systems have rapidly changed and today hospital care is primarily advocated for critical patients and acute treatments, for which laboratory test results are crucial and need to be always reported in predictably short turnaround time (TAT). Laboratories in the hospital setting can face this challenge by changing their organization from a compartmentalized laboratory department toward a decision making-based laboratory department. This requires the implementation of a core laboratory, that exploits total laboratory automation (TLA) using technological innovation in analytical platforms, track systems and information technology, including middleware, and a number of satellite specialized laboratory sections cooperating with care teams for specific medical conditions. In this laboratory department model, the short TAT for all first-line tests performed by TLA in the core laboratory represents the key paradigm, where no more stat testing is required because all samples are handled in real-time and (auto)validated results dispatched in a time that fulfills clinical needs. To optimally reach this goal, laboratories should be actively involved in managing all the steps covering the total examination process, speeding up also extra-laboratory phases, such sample delivery. Furthermore, to warrant effectiveness and not only efficiency, all the processes, e.g. specimen integrity check, should be managed by middleware through a predefined set of rules defined in light of the clinical governance. Crown Copyright © 2017. Published by Elsevier Inc. All rights reserved.

  8. Changes in total carbohydrate and total antioxidant activity induced by gamma irradiation of wheat flour

    International Nuclear Information System (INIS)

    Manupriya, B.R.; Shenoy, K. Bhasker; Patil, Shrikant L.; Somashekarappa, H.M.

    2015-01-01

    Wheat is a staple food grain in India after rice and occupies number one position in the world. The wheat crop not only gives food grains but also gives fodder for animals. Among many preservation methods irradiation is a current technique used to overcome infestation, contamination and spoilage of stored grains. The present study is aimed to check the changes in composition of irradiated wheat flour. Wheat flour was exposed to five different irradiation doses (0.25 KGy, 0.5KGy, 1KGy, 5KGy and 10 KGy) by using 60 Co gamma-irradiation chamber. Irradiated flour was stored in air sealed polyethylene pouch and plastic container at room temperature for different time intervals (0 th day, 1 month and 3 months). The stored flour was checked for total antioxidant activity by phosphomolybdate method and total carbohydrates concentration by phenol-sulphuric acid method. On 0 th day total antioxidant activity and total carbohydrate concentration was found to be increased at 0.5KGy (0.113 mg/ml and 0.045 mg/ml respectively) when compared to control (0.79 mg/ml and 39.5 mg/ml). Similarly for 1 month stored samples of air sealed polyethylene pouch total antioxidant activity and total carbohydrate concentration was observed to be increased at 0.5KGy (0.117 mg/ml and 0.045mg/ml respectively) when compared to control (0.096 mg/ml and 0.035 mg/ml). But in case of stored samples of plastic container total antioxidant activity increased at 0.25KGy (0.060 mg/ml) and total carbohydrate increased at 5KGy (0.051 mg/ml). Increased and decreased values were found in both factors for 3 months stored samples of air sealed polyethylene pouch and plastic container. Total antioxidant activity increased at 5KGy (0.072 mg/ml) for polyethylene bag samples and at 0.5KGy (0.137 mg/ml) for plastic container sample. Same way total carbohydrate concentration increased at 0.25KGy (0.046 mg/ml) and at 1KGy (0.045 mg/ml) respectively. This increase is due to affects of γ-irradiation on biomolecules by

  9. Assessment of the total uranium concentration in surface and underground water samples from the Caetite region, Bahia, Brazil

    International Nuclear Information System (INIS)

    Silva, Julia Grasiela Batista; Geraldo, Luiz Paulo; Yamazaki, Ione Makiko

    2011-01-01

    At the region of Caetite, BA, it is located the largest uranium mine in exploration at present days in Brazil. During the uranium extraction process, it may be having an environmental contamination by this heavy metal due to rain water and other natural transport mechanism, with potential exposition risk to the local population. The aim of this work was to investigate the total uranium concentration in surface and underground water samples collected at the Caetite region, using the nuclear track registration technique (SSNTD) in a polycarbonate plastic. A 100 mL volume of water samples were initially treated in 10 mL of HNO 3 (PA) and concentrated by evaporation at a temperature around 80 deg C. The resulting residue was diluted to a total volume of 25 mL without pass it to a filter. About 10 μL of this solution was deposited on the plastic detector surface (around 1.0 cm 2 area) together with 5 μL of a Cyastat detergent solution (5%) and evaporated under an infrared lamp. All the resulting deposits of non volatile constituents were irradiated, together with a uranium standard sample, at the IPEN-IEA-R1 (3.5 MW) nuclear reactor for approximately 3 min. After irradiations, chemical etching of the plastic detectors was carried out at 60 deg C, for 65 min. in a NaOH (6N) solution. The fission tracks were counted scanning all the deposit area of the polycarbonate plastic detector with a system consisting of an optical microscope together with a video camera and TV monitor. The average values of uranium concentrations obtained in this work ranged from (0.95±0.19) μg.L -1 to (25.60±3.3) μg.L -1 . These results were compared to values reported in the literature for water samples from other regions and discussed in terms of safe limits recommended by WHO -World Health Organization and CONAMA - Conselho Nacional do Meio Ambiente. (author)

  10. Assessment of the total uranium concentration in surface and underground water samples from the Caetite region, Bahia, Brazil

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Julia Grasiela Batista; Geraldo, Luiz Paulo [Centro Universitario da Fundacao Educacional de Barretos (UNIFEB), (SP) (Brazil); Yamazaki, Ione Makiko [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2011-07-01

    At the region of Caetite, BA, it is located the largest uranium mine in exploration at present days in Brazil. During the uranium extraction process, it may be having an environmental contamination by this heavy metal due to rain water and other natural transport mechanism, with potential exposition risk to the local population. The aim of this work was to investigate the total uranium concentration in surface and underground water samples collected at the Caetite region, using the nuclear track registration technique (SSNTD) in a polycarbonate plastic. A 100 mL volume of water samples were initially treated in 10 mL of HNO{sub 3} (PA) and concentrated by evaporation at a temperature around 80 deg C. The resulting residue was diluted to a total volume of 25 mL without pass it to a filter. About 10 {mu}L of this solution was deposited on the plastic detector surface (around 1.0 cm{sup 2} area) together with 5 {mu}L of a Cyastat detergent solution (5%) and evaporated under an infrared lamp. All the resulting deposits of non volatile constituents were irradiated, together with a uranium standard sample, at the IPEN-IEA-R1 (3.5 MW) nuclear reactor for approximately 3 min. After irradiations, chemical etching of the plastic detectors was carried out at 60 deg C, for 65 min. in a NaOH (6N) solution. The fission tracks were counted scanning all the deposit area of the polycarbonate plastic detector with a system consisting of an optical microscope together with a video camera and TV monitor. The average values of uranium concentrations obtained in this work ranged from (0.95{+-}0.19) {mu}g.L{sup -1} to (25.60{+-}3.3) {mu}g.L{sup -1}. These results were compared to values reported in the literature for water samples from other regions and discussed in terms of safe limits recommended by WHO -World Health Organization and CONAMA - Conselho Nacional do Meio Ambiente. (author)

  11. Mechanical Conversion for High-Throughput TEM Sample Preparation

    International Nuclear Information System (INIS)

    Kendrick, Anthony B; Moore, Thomas M; Zaykova-Feldman, Lyudmila

    2006-01-01

    This paper presents a novel method of direct mechanical conversion from lift-out sample to TEM sample holder. The lift-out sample is prepared in the FIB using the in-situ liftout Total Release TM method. The mechanical conversion is conducted using a mechanical press and one of a variety of TEM coupons, including coupons for both top-side and back-side thinning. The press joins a probe tip point with attached TEM sample to the sample coupon and separates the complete assembly as a 3mm diameter TEM grid, compatible with commercially available TEM sample holder rods. This mechanical conversion process lends itself well to the high through-put requirements of in-line process control and to materials characterization labs where instrument utilization and sample security are critically important

  12. The real-time fitting of radioactive decay curves. Pt. 3. Counting during sampling

    International Nuclear Information System (INIS)

    Hartley, B.M.

    1994-01-01

    An analysis of a least-squares method for the real-time fitting of the theoretical total count function to the actual total count from radioactive decays has been given previously for the case where counting takes place after a sample is taken. The counting may be done in a number of different counting systems which distinguish between different types or energies of radiation emitted from the sample. The method would allow real-time determination of the numbers of atoms and hence activities of the individual isotopes present and has been designated the Time Evolved Least-Squares method (TELS). If the radioactivity which is to be measured exists as an aerosol or in a form where a sample is taken at a constant rate it may be possible to count during sampling and by so doing reduce the total time required to determine the activity of the individual isotopes present. The TELS method is extended here to the case where counting and the evaluation of the activity takes place concurrently with the sampling. The functions which need to be evaluated are derived and the calculations required to implement the method are discussed. As with the TELS method of counting after sampling the technique of counting during sampling and the simultaneous evaluation of activity could be achieved in real-time. Results of testing the method by computer simulation for two counting schemes for the descendants of radon are presented. ((orig.))

  13. Simplified sample treatment for the determination of total concentrations and chemical fractionation forms of Ca, Fe, Mg and Mn in soluble coffees.

    Science.gov (United States)

    Pohl, Pawel; Stelmach, Ewelina; Szymczycha-Madeja, Anna

    2014-11-15

    A simpler, and faster than wet digestion, sample treatment was proposed prior to determination of total concentrations for selected macro- (Ca, Mg) and microelements (Fe, Mn) in soluble coffees by flame atomic absorption spectrometry. Samples were dissolved in water and acidified with HNO3. Precision was in the range 1-4% and accuracy was better than 2.5%. The method was used in analysis of 18 soluble coffees available on the Polish market. Chemical fractionation patterns for Ca, Fe, Mg and Mn in soluble coffees, as consumed, using a two-column solid-phase extraction method, determined Ca, Mg and Mn were present predominantly as cations (80-93% of total content). This suggests these elements are likely to be highly bioaccessible. Copyright © 2014 Elsevier Ltd. All rights reserved.

  14. Determination of inorganic mercury and total mercury in biological and environmental samples by flow injection-cold vapor-atomic absorption spectrometry using sodium borohydride as the sole reducing agent

    International Nuclear Information System (INIS)

    Rio Segade, Susana; Tyson, Julian F.

    2003-01-01

    A simple, fast, precise and accurate method to determine inorganic mercury and total mercury in biological and environmental samples was developed. The optimized flow-injection mercury system permitted the separate determination of inorganic mercury and total mercury using sodium borohydride as reducing agent. Inorganic mercury was selectively determined after reduction with 10 -4 % w/v sodium borohydride, while total mercury was determined after reduction with 0.75% w/v sodium borohydride. The calibration graphs were linear up to 30 ng ml -1 . The detection limits of the method based on three times the standard deviation of the blank were 24 and 3.9 ng l -1 for total mercury and inorganic mercury determination, respectively. The relative standard deviation was less than 1.5% for a 10 ng ml -1 mercury standard. As a means of checking method performance, deionized water and pond water samples were spiked with methylmercury and inorganic mercury; quantitative recovery for total mercury and inorganic mercury was obtained. The accuracy of the method was verified by analyzing alkaline and acid extracts of five biological and sediment reference materials. Microwave-assisted extraction procedures resulted in higher concentrations of recovered mercury species, lower matrix interference with mercury determination and less time involved in sample treatment than conventional extraction procedures. The standard addition method was only needed for calibration when biological samples were analyzed. The detection limits were in the range of 1.2-19 and 6.6-18 ng g -1 in biological and sediment samples for inorganic mercury and total mercury determination, respectively

  15. Total reflection x-ray fluorescence spectroscopy as a tool for evaluation of iron concentration in ferrofluids and yeast samples

    Energy Technology Data Exchange (ETDEWEB)

    Kulesh, N.A., E-mail: nikita.kulesh@urfu.ru [Ural Federal University, Mira 19, 620002 Ekaterinburg (Russian Federation); Novoselova, I.P. [Ural Federal University, Mira 19, 620002 Ekaterinburg (Russian Federation); Immanuel Kant Baltic Federal University, 236041 Kaliningrad (Russian Federation); Safronov, A.P. [Ural Federal University, Mira 19, 620002 Ekaterinburg (Russian Federation); Institute of Electrophysics UD RAS, Amundsen 106, 620016 Ekaterinburg (Russian Federation); Beketov, I.V.; Samatov, O.M. [Institute of Electrophysics UD RAS, Amundsen 106, 620016 Ekaterinburg (Russian Federation); Kurlyandskaya, G.V. [Ural Federal University, Mira 19, 620002 Ekaterinburg (Russian Federation); University of the Basque Country UPV-EHU, 48940 Leioa (Spain); Morozova, M. [Ural Federal University, Mira 19, 620002 Ekaterinburg (Russian Federation); Denisova, T.P. [Irkutsk State University, Karl Marks 1, 664003 Irkutsk (Russian Federation)

    2016-10-01

    In this study, total reflection x-ray fluorescent (TXRF) spectrometry was applied for the evaluation of iron concentration in ferrofluids and biological samples containing iron oxide magnetic nanoparticles obtained by the laser target evaporation technique. Suspensions of maghemite nanoparticles of different concentrations were used to estimate the limitation of the method for the evaluation of nanoparticle concentration in the range of 1–5000 ppm in absence of organic matrix. Samples of single-cell yeasts grown in the nutrient media containing maghemite nanoparticles were used to study the nanoparticle absorption mechanism. The obtained results were analyzed in terms of applicability of TXRF for quantitative analysis in a wide range of iron oxide nanoparticle concentrations for biological samples and ferrofluids with a simple established protocol of specimen preparation. - Highlights: • Ferrofluids and yeasts samples were analysed by TXRF spectroscopy. • Simple protocol for iron quantification by means of TXRF was proposed. • Results were combined with magnetic, structural, and morphological characterization. • Preliminary conclusion on nanoparticles uptake mechanism was made.

  16. Total reflection x-ray fluorescence spectroscopy as a tool for evaluation of iron concentration in ferrofluids and yeast samples

    International Nuclear Information System (INIS)

    Kulesh, N.A.; Novoselova, I.P.; Safronov, A.P.; Beketov, I.V.; Samatov, O.M.; Kurlyandskaya, G.V.; Morozova, M.; Denisova, T.P.

    2016-01-01

    In this study, total reflection x-ray fluorescent (TXRF) spectrometry was applied for the evaluation of iron concentration in ferrofluids and biological samples containing iron oxide magnetic nanoparticles obtained by the laser target evaporation technique. Suspensions of maghemite nanoparticles of different concentrations were used to estimate the limitation of the method for the evaluation of nanoparticle concentration in the range of 1–5000 ppm in absence of organic matrix. Samples of single-cell yeasts grown in the nutrient media containing maghemite nanoparticles were used to study the nanoparticle absorption mechanism. The obtained results were analyzed in terms of applicability of TXRF for quantitative analysis in a wide range of iron oxide nanoparticle concentrations for biological samples and ferrofluids with a simple established protocol of specimen preparation. - Highlights: • Ferrofluids and yeasts samples were analysed by TXRF spectroscopy. • Simple protocol for iron quantification by means of TXRF was proposed. • Results were combined with magnetic, structural, and morphological characterization. • Preliminary conclusion on nanoparticles uptake mechanism was made.

  17. Allogenic blood transfusion following total hip arthroplasty: results from the nationwide inpatient sample, 2000 to 2009.

    Science.gov (United States)

    Saleh, Anas; Small, Travis; Chandran Pillai, Aiswarya Lekshmi Pillai; Schiltz, Nicholas K; Klika, Alison K; Barsoum, Wael K

    2014-09-17

    The large-scale utilization of allogenic blood transfusion and its associated outcomes have been described in critically ill patients and those undergoing high-risk cardiac surgery but not in patients undergoing elective total hip arthroplasty. The objective of this study was to determine the trends in utilization and outcomes of allogenic blood transfusion in patients undergoing primary total hip arthroplasty in the United States from 2000 to 2009. An observational cohort of 2,087,423 patients who underwent primary total hip arthroplasty from 2000 to 2009 was identified in the Nationwide Inpatient Sample. International Classification of Diseases, Ninth Revision, Clinical Modification procedure codes 99.03 and 99.04 were used to identify patients who received allogenic blood products during their hospital stay. Risk factors for allogenic transfusions were identified with use of multivariable logistic regression models. We used propensity score matching to estimate the adjusted association between transfusion and surgical outcomes. The rate of allogenic blood transfusion increased from 11.8% in 2000 to 19.0% in 2009. Patient-related risk factors for receiving an allogenic blood transfusion include an older age, female sex, black race, and Medicaid insurance. Hospital-related risk factors include rural location, smaller size, and non-academic status. After adjusting for confounders, allogenic blood transfusion was associated with a longer hospital stay (0.58 ± 0.02 day; p conservation methods. Copyright © 2014 by The Journal of Bone and Joint Surgery, Incorporated.

  18. Monitoring of total metal concentration in sludge samples: Case study for the mechanical–biological wastewater treatment plant in Velika Gorica, Croatia

    International Nuclear Information System (INIS)

    Filipović, Josip; Grčić, Ivana; Bermanec, Vladimir; Kniewald, Goran

    2013-01-01

    In this paper, monitoring of total metal concentration in sludge samples from wastewater treatment process is elaborated. The presented results summarize the analyses of sludge samples in a period from 2008 to 2012. Possible sources of pollutions are given. Primarily, waste solid samples were collected from different pretreatment steps: (A) coarse grid, (B) fine grid and (C) aerated sand grease grid. Samples of A and B followed a repeatable pattern in 2008 and 2010. According to the results from 2008, samples of C contained measurable concentration of the following metals (mg/kg dry matter): Zn (21), Ni (1.05) and Ba (14.9). Several types of sludge samples were analyzed: fresh raw sludge (PS; 6–12 hour old), the sludge from the digester for anaerobic sludge treatment (DS; 48–72 hour old), samples from lagoons where the sludge is temporarily deposited (DOS and DOSold; 30–120 days) and sludge samples from agricultural areas (AA; aged over 180 days). Additionally, samples of dehydrated sludge (DEHS and DEHSold; 90–180 days) were collected upon construction of equipment for sludge dehydration in 2011. An analysis of total metal concentrations for Cu, Zn, Cr, Pb, Ni, Hg, Cd, Ba, As, Se, Sb, Co, Mo, Fe and Mn was performed by flame atomic absorption spectrometry (FAAS) and inductively coupled plasma-optical emission spectrometry (ICP-OES). The most recent results (year 2011) indicated a high concentration of heavy metals in PS samples, exceeding the MCLs (mg/kg dry matter): Cu (2122), Zn (5945), Hg (13.67) and Cd (6.29). In 2012 (until July), only a concentration of Cu exceeded MCL (928.75 and 1230.5 in DS and DEHS, respectively). A composition of sludge was variable through time, offering the limited possibility for future prediction. The sludge is being considered as a hazardous waste and a subject of discussion regarding disposal. - Highlights: ► Summarized 5-year monitoring data for heavy metals in sludge ► Partially determined sources of pollution by

  19. Monitoring of total metal concentration in sludge samples: Case study for the mechanical–biological wastewater treatment plant in Velika Gorica, Croatia

    Energy Technology Data Exchange (ETDEWEB)

    Filipović, Josip [Town Office for Physical Planning and Environmental Protection, Velika Gorica County, Trg kralja Tomislava 34, 10410 Velika Gorica (Croatia); Grčić, Ivana, E-mail: igrcic@fkit.hr [Faculty of Chemical Engineering and Technology, University of Zagreb Marulićev trg 19, 10000 Zagreb (Croatia); Bermanec, Vladimir [Institute of Mineralogy and Petrology, Faculty of Science, University of Zagreb, Horvatovac bb, 10000 Zagreb (Croatia); Kniewald, Goran [Division for Marine and Environmental Research, Ruđer Bošković Institute, Bijenička 54, 10000 Zagreb (Croatia)

    2013-03-01

    In this paper, monitoring of total metal concentration in sludge samples from wastewater treatment process is elaborated. The presented results summarize the analyses of sludge samples in a period from 2008 to 2012. Possible sources of pollutions are given. Primarily, waste solid samples were collected from different pretreatment steps: (A) coarse grid, (B) fine grid and (C) aerated sand grease grid. Samples of A and B followed a repeatable pattern in 2008 and 2010. According to the results from 2008, samples of C contained measurable concentration of the following metals (mg/kg dry matter): Zn (21), Ni (1.05) and Ba (14.9). Several types of sludge samples were analyzed: fresh raw sludge (PS; 6–12 hour old), the sludge from the digester for anaerobic sludge treatment (DS; 48–72 hour old), samples from lagoons where the sludge is temporarily deposited (DOS and DOSold; 30–120 days) and sludge samples from agricultural areas (AA; aged over 180 days). Additionally, samples of dehydrated sludge (DEHS and DEHSold; 90–180 days) were collected upon construction of equipment for sludge dehydration in 2011. An analysis of total metal concentrations for Cu, Zn, Cr, Pb, Ni, Hg, Cd, Ba, As, Se, Sb, Co, Mo, Fe and Mn was performed by flame atomic absorption spectrometry (FAAS) and inductively coupled plasma-optical emission spectrometry (ICP-OES). The most recent results (year 2011) indicated a high concentration of heavy metals in PS samples, exceeding the MCLs (mg/kg dry matter): Cu (2122), Zn (5945), Hg (13.67) and Cd (6.29). In 2012 (until July), only a concentration of Cu exceeded MCL (928.75 and 1230.5 in DS and DEHS, respectively). A composition of sludge was variable through time, offering the limited possibility for future prediction. The sludge is being considered as a hazardous waste and a subject of discussion regarding disposal. - Highlights: ► Summarized 5-year monitoring data for heavy metals in sludge ► Partially determined sources of pollution by

  20. Total pollution effect of urban surface runoff.

    Science.gov (United States)

    Luo, Hongbing; Luo, Lin; Huang, Gu; Liu, Ping; Li, Jingxian; Hu, Sheng; Wang, Fuxiang; Xu, Rui; Huang, Xiaoxue

    2009-01-01

    For pollution research with regard to urban surface runoff, most sampling strategies to date have focused on differences in land usage. With single land-use sampling, total surface runoff pollution effect cannot be evaluated unless every land usage spot is monitored. Through a new sampling strategy known as mixed stormwater sampling for a street community at discharge outlet adjacent to river, this study assessed the total urban surface runoff pollution effect caused by a variety of land uses and the pollutants washed off from the rain pipe system in the Futian River watershed in Shenzhen City of China. The water quality monitoring indices were COD (chemical oxygen demand), TSS (total suspend solid), TP (total phosphorus), TN (total nitrogen) and BOD (biochemical oxygen demand). The sums of total pollution loads discharged into the river for the four indices of COD, TSS, TN, and TP over all seven rainfall events were very different. The mathematical model for simulating total pollution loads was established from discharge outlet mixed stormwater sampling of total pollution loads on the basis of four parameters: rainfall intensity, total land area, impervious land area, and pervious land area. In order to treat surface runoff pollution, the values of MFF30 (mass first flush ratio) and FF30 (first 30% of runoff volume) can be considered as split-flow control criteria to obtain more effective and economical design of structural BMPs (best management practices) facilities.

  1. Dispersive liquid-liquid microextraction coupled with digital image colorimetric analysis for detection of total iron in water and food samples.

    Science.gov (United States)

    Peng, Bo; Chen, Guorong; Li, Kai; Zhou, Min; Zhang, Ji; Zhao, Shengguo

    2017-09-01

    A simple and low cost assay for total iron in various samples based on dispersive liquid-liquid microextraction (DLLME) coupled with digital scanning image analysis was proposed. Orthogonal experiment design was utilized to optimize the amount of extraction solvent and disperser solvent, O-phenanthroline concentration and buffer pH. Under the optimum conditions, the calibration curve was linear over the range of 0.047-1.0μgmL -1 (R 2 >0.99) of iron. The limit of detection (LOD) for iron was 14.1μgL -1 and limit of quantification (LOQ) was 46.5μgL -1 . The relative standard deviations for seven replicate determinations of 0.5μgmL -1 of iron was 3.75%. The method was successfully applied for analysis of total iron in water and food samples without using any spectral instrument and it could have a potential industrial impact in developing fast and portable devices to analyze the iron content in water and certain foods. Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. Distribution of Total Depressive Symptoms Scores and Each Depressive Symptom Item in a Sample of Japanese Employees.

    Science.gov (United States)

    Tomitaka, Shinichiro; Kawasaki, Yohei; Ide, Kazuki; Yamada, Hiroshi; Miyake, Hirotsugu; Furukawa, Toshiaki A; Furukaw, Toshiaki A

    2016-01-01

    In a previous study, we reported that the distribution of total depressive symptoms scores according to the Center for Epidemiologic Studies Depression Scale (CES-D) in a general population is stable throughout middle adulthood and follows an exponential pattern except for at the lowest end of the symptom score. Furthermore, the individual distributions of 16 negative symptom items of the CES-D exhibit a common mathematical pattern. To confirm the reproducibility of these findings, we investigated the distribution of total depressive symptoms scores and 16 negative symptom items in a sample of Japanese employees. We analyzed 7624 employees aged 20-59 years who had participated in the Northern Japan Occupational Health Promotion Centers Collaboration Study for Mental Health. Depressive symptoms were assessed using the CES-D. The CES-D contains 20 items, each of which is scored in four grades: "rarely," "some," "much," and "most of the time." The descriptive statistics and frequency curves of the distributions were then compared according to age group. The distribution of total depressive symptoms scores appeared to be stable from 30-59 years. The right tail of the distribution for ages 30-59 years exhibited a linear pattern with a log-normal scale. The distributions of the 16 individual negative symptom items of the CES-D exhibited a common mathematical pattern which displayed different distributions with a boundary at "some." The distributions of the 16 negative symptom items from "some" to "most" followed a linear pattern with a log-normal scale. The distributions of the total depressive symptoms scores and individual negative symptom items in a Japanese occupational setting show the same patterns as those observed in a general population. These results show that the specific mathematical patterns of the distributions of total depressive symptoms scores and individual negative symptom items can be reproduced in an occupational population.

  3. Trace determination of uranium in fertilizer samples by total ...

    Indian Academy of Sciences (India)

    the fertilizers is important because it can be used as fuel in nuclear reactors and also because of en- vironmental concerns. ... The amounts of uranium in four fertilizer samples of Hungarian origin were determined by ... TXRF determination of uranium from phosphate fertilizers of Hungarian origin and the preliminary results ...

  4. Development of a Univariate Membrane-Based Mid-Infrared Method for Protein Quantitation and Total Lipid Content Analysis of Biological Samples

    Directory of Open Access Journals (Sweden)

    Ivona Strug

    2014-01-01

    Full Text Available Biological samples present a range of complexities from homogeneous purified protein to multicomponent mixtures. Accurate qualification of such samples is paramount to downstream applications. We describe the development of an MIR spectroscopy-based analytical method offering simultaneous protein quantitation (0.25–5 mg/mL and analysis of total lipid or detergent species, as well as the identification of other biomolecules present in biological samples. The method utilizes a hydrophilic PTFE membrane engineered for presentation of aqueous samples in a dried format compatible with fast infrared analysis. Unlike classical quantification techniques, the reported method is amino acid sequence independent and thus applicable to complex samples of unknown composition. By comparison to existing platforms, this MIR-based method enables direct quantification using minimal sample volume (2 µL; it is well-suited where repeat access and limited sample size are critical parameters. Further, accurate results can be derived without specialized training or knowledge of IR spectroscopy. Overall, the simplified application and analysis system provides a more cost-effective alternative to high-throughput IR systems for research laboratories with minimal throughput demands. In summary, the MIR-based system provides a viable alternative to current protein quantitation methods; it also uniquely offers simultaneous qualification of other components, notably lipids and detergents.

  5. Modern survey sampling

    CERN Document Server

    Chaudhuri, Arijit

    2014-01-01

    Exposure to SamplingAbstract Introduction Concepts of Population, Sample, and SamplingInitial RamificationsAbstract Introduction Sampling Design, Sampling SchemeRandom Numbers and Their Uses in Simple RandomSampling (SRS)Drawing Simple Random Samples with and withoutReplacementEstimation of Mean, Total, Ratio of Totals/Means:Variance and Variance EstimationDetermination of Sample SizesA.2 Appendix to Chapter 2 A.More on Equal Probability Sampling A.Horvitz-Thompson EstimatorA.SufficiencyA.LikelihoodA.Non-Existence Theorem More Intricacies Abstract Introduction Unequal Probability Sampling StrategiesPPS Sampling Exploring Improved WaysAbstract Introduction Stratified Sampling Cluster SamplingMulti-Stage SamplingMulti-Phase Sampling: Ratio and RegressionEstimationviiviii ContentsControlled SamplingModeling Introduction Super-Population ModelingPrediction Approach Model-Assisted Approach Bayesian Methods Spatial SmoothingSampling on Successive Occasions: Panel Rotation Non-Response and Not-at-Homes Weighting Adj...

  6. Robust identification of noncoding RNA from transcriptomes requires phylogenetically-informed sampling.

    Directory of Open Access Journals (Sweden)

    Stinus Lindgreen

    2014-10-01

    Full Text Available Noncoding RNAs are integral to a wide range of biological processes, including translation, gene regulation, host-pathogen interactions and environmental sensing. While genomics is now a mature field, our capacity to identify noncoding RNA elements in bacterial and archaeal genomes is hampered by the difficulty of de novo identification. The emergence of new technologies for characterizing transcriptome outputs, notably RNA-seq, are improving noncoding RNA identification and expression quantification. However, a major challenge is to robustly distinguish functional outputs from transcriptional noise. To establish whether annotation of existing transcriptome data has effectively captured all functional outputs, we analysed over 400 publicly available RNA-seq datasets spanning 37 different Archaea and Bacteria. Using comparative tools, we identify close to a thousand highly-expressed candidate noncoding RNAs. However, our analyses reveal that capacity to identify noncoding RNA outputs is strongly dependent on phylogenetic sampling. Surprisingly, and in stark contrast to protein-coding genes, the phylogenetic window for effective use of comparative methods is perversely narrow: aggregating public datasets only produced one phylogenetic cluster where these tools could be used to robustly separate unannotated noncoding RNAs from a null hypothesis of transcriptional noise. Our results show that for the full potential of transcriptomics data to be realized, a change in experimental design is paramount: effective transcriptomics requires phylogeny-aware sampling.

  7. Determination of daily intake of elements from Philippine total diet samples using inductively coupled plasma-atomic emission spectrometry

    International Nuclear Information System (INIS)

    Leon, G.C. de; Shiraishi, K.; Kawamura, H.; Igaraishi, Y.; Palattao, M.V.; Azanon, E.M.

    1990-10-01

    Total diet samples were analyzed for major elements (Na, K, Ca, Mg, P) and some minor trace elements (Fe, Zn, Mn, Al, Sr, Cu, Ba, Yt) using inductively coupled plasma-atomic emission spectrometry (ICP-AES). Samples analyzed were classified into sex and age groups. Results for some elements (Na, K, Mg, Zn, Cu, Mn) were compared with values from Bataan dietary survey calculated using the Philippine composition table. Exceot for Na, analytical results were similar to calculated values. Analytical results for Ca and Fe were also compared with the values from Food and Nutrition Research Institute. In general, values obtained in the study were lower than the FNRI values. Comparison of the analytical and calculated results with the Japanese and ICRP data showed that Philippine values were lower than foreign values. (Auth.). 22 refs., 9 tabs

  8. Determining the number of samples required for decisions concerning remedial actions at hazardous waste sites

    International Nuclear Information System (INIS)

    Skiles, J.L.; Redfearn, A.; White, R.K.

    1991-01-01

    The processing of collecting, analyzing, and assessing the data needed to make to make decisions concerning the cleanup of hazardous waste sites is quite complex and often very expensive. This is due to the many elements that must be considered during remedial investigations. The decision maker must have sufficient data to determine the potential risks to human health and the environment and to verify compliance with regulatory requirements, given the availability of resources allocated for a site, and time constraints specified for the completion of the decision making process. It is desirable to simplify the remedial investigation procedure as much as possible to conserve both time and resources while, simultaneously, minimizing the probability of error associated with each decision to be made. With this in mind, it is necessary to have a practical and statistically valid technique for estimating the number of on-site samples required to ''guarantee'' that the correct decisions are made with a specified precision and confidence level. Here, we will examine existing methodologies and then develop our own approach for determining a statistically defensible sample size based on specific guidelines that have been established for the risk assessment process

  9. Trace determination of uranium in fertilizer samples by total ...

    Indian Academy of Sciences (India)

    Uranium is reported to be present in phosphate fertilizers. The recovery of uranium from the fertilizers is important because it can be used as fuel in nuclear reactors and also because of environmental concerns. For both these activities suitable method of uranium determinations at trace levels in these fertilizers are required.

  10. PENETAPAN KADAR FENOLIK TOTAL DAN FLAVONOID TOTAL EKSTRAK BERAS HITAM (Oryza sativa L DARI KALIMANTAN SELATAN

    Directory of Open Access Journals (Sweden)

    Anna Khumaira Sari

    2017-10-01

    Full Text Available The black rice contains anthocyanin compounds which are included in the flavonoids and phenolic compounds. Flavonoids contained in black rice are phenolic components that act as a preventive of hydroxyl and superoxide radicals by protecting membrane lipids against damaging oxidation reactions and phenol compounds also have bacteriocid, antimetic, antihelmintic, antiinflammatory, antimicrobial, anticancer and other degenerative diseases. The aim of this research were to measure total phenolic content and total flavonoid in ethanol extract of black rice (Oryza sativa L. Total phenol content were measured by Folin-Ciocalteu method with gallic acid mean while total flavonoid content were measured by colorimetry method using reagent AlCl3 10% and 5% acetic acid. There are seven variation samples of black rice obtained from seven different places in South Kalimantan. The result of this study, qualitative analysis showed that all samples positive contained flavonoids, alkaloids and tannins. The total phenol content of the seven samples was 100,58 ± 1,344; 91.14 ± 1.699; 96.50 ± 1.529; 77.64 ± 0.462; 81,16 ± 0,614; 112.47 ± 1.040; 81,50 ± 2,928 mgGAE/mg extract and the percent of total flavonoid content from seven samples was 8,53 ± 0,208%; 8.11 ± 0.343%; 7.69 ± 0.446%; 6.03 ± 0.227%; 4.97 ± 0.169%; 3.74 ± 0.210%; 5.02 ± 0.403%.

  11. 26 CFR 1.801-5 - Total reserves.

    Science.gov (United States)

    2010-04-01

    ... TAXES Life Insurance Companies § 1.801-5 Total reserves. (a) Total reserves defined. For purposes of... its highest aggregate reserve by taking State A's requirement of 10 against its life insurance business and adding it to State B's requirement of 7 against its annuity business. (b) Reserves required by...

  12. High resolution x-ray microtomography of biological samples: Requirements and strategies for satisfying them

    Energy Technology Data Exchange (ETDEWEB)

    Loo, B.W. Jr. [Univ. of California, San Francisco, CA (United States)]|[Univ. of California, Davis, CA (United States)]|[Lawrence Berkeley National Lab., CA (United States); Rothman, S.S. [Univ. of California, San Francisco, CA (United States)]|[Lawrence Berkeley National Lab., CA (United States)

    1997-02-01

    High resolution x-ray microscopy has been made possible in recent years primarily by two new technologies: microfabricated diffractive lenses for soft x-rays with about 30-50 nm resolution, and high brightness synchrotron x-ray sources. X-ray microscopy occupies a special niche in the array of biological microscopic imaging methods. It extends the capabilities of existing techniques mainly in two areas: a previously unachievable combination of sub-visible resolution and multi-micrometer sample size, and new contrast mechanisms. Because of the soft x-ray wavelengths used in biological imaging (about 1-4 nm), XM is intermediate in resolution between visible light and electron microscopies. Similarly, the penetration depth of soft x-rays in biological materials is such that the ideal sample thickness for XM falls in the range of 0.25 - 10 {mu}m, between that of VLM and EM. XM is therefore valuable for imaging of intermediate level ultrastructure, requiring sub-visible resolutions, in intact cells and subcellular organelles, without artifacts produced by thin sectioning. Many of the contrast producing and sample preparation techniques developed for VLM and EM also work well with XM. These include, for example, molecule specific staining by antibodies with heavy metal or fluorescent labels attached, and sectioning of both frozen and plastic embedded tissue. However, there is also a contrast mechanism unique to XM that exists naturally because a number of elemental absorption edges lie in the wavelength range used. In particular, between the oxygen and carbon absorption edges (2.3 and 4.4 nm wavelength), organic molecules absorb photons much more strongly than does water, permitting element-specific imaging of cellular structure in aqueous media, with no artifically introduced contrast agents. For three-dimensional imaging applications requiring the capabilities of XM, an obvious extension of the technique would therefore be computerized x-ray microtomography (XMT).

  13. Optimal sampling plan for clean development mechanism energy efficiency lighting projects

    International Nuclear Information System (INIS)

    Ye, Xianming; Xia, Xiaohua; Zhang, Jiangfeng

    2013-01-01

    Highlights: • A metering cost minimisation model is built to assist the sampling plan for CDM projects. • The model minimises the total metering cost by the determination of optimal sample size. • The required 90/10 criterion sampling accuracy is maintained. • The proposed metering cost minimisation model is applicable to other CDM projects as well. - Abstract: Clean development mechanism (CDM) project developers are always interested in achieving required measurement accuracies with the least metering cost. In this paper, a metering cost minimisation model is proposed for the sampling plan of a specific CDM energy efficiency lighting project. The problem arises from the particular CDM sampling requirement of 90% confidence and 10% precision for the small-scale CDM energy efficiency projects, which is known as the 90/10 criterion. The 90/10 criterion can be met through solving the metering cost minimisation problem. All the lights in the project are classified into different groups according to uncertainties of the lighting energy consumption, which are characterised by their statistical coefficient of variance (CV). Samples from each group are randomly selected to install power meters. These meters include less expensive ones with less functionality and more expensive ones with greater functionality. The metering cost minimisation model will minimise the total metering cost through the determination of the optimal sample size at each group. The 90/10 criterion is formulated as constraints to the metering cost objective. The optimal solution to the minimisation problem will therefore minimise the metering cost whilst meeting the 90/10 criterion, and this is verified by a case study. Relationships between the optimal metering cost and the population sizes of the groups, CV values and the meter equipment cost are further explored in three simulations. The metering cost minimisation model proposed for lighting systems is applicable to other CDM projects as

  14. Total error components - isolation of laboratory variation from method performance

    International Nuclear Information System (INIS)

    Bottrell, D.; Bleyler, R.; Fisk, J.; Hiatt, M.

    1992-01-01

    The consideration of total error across sampling and analytical components of environmental measurements is relatively recent. The U.S. Environmental Protection Agency (EPA), through the Contract Laboratory Program (CLP), provides complete analyses and documented reports on approximately 70,000 samples per year. The quality assurance (QA) functions of the CLP procedures provide an ideal data base-CLP Automated Results Data Base (CARD)-to evaluate program performance relative to quality control (QC) criteria and to evaluate the analysis of blind samples. Repetitive analyses of blind samples within each participating laboratory provide a mechanism to separate laboratory and method performance. Isolation of error sources is necessary to identify effective options to establish performance expectations, and to improve procedures. In addition, optimized method performance is necessary to identify significant effects that result from the selection among alternative procedures in the data collection process (e.g., sampling device, storage container, mode of sample transit, etc.). This information is necessary to evaluate data quality; to understand overall quality; and to provide appropriate, cost-effective information required to support a specific decision

  15. Application of Terahertz Attenuated Total Reflection Spectroscopy to Detect Changes in the Physical Properties of Lactose during the Lubrication Process Required for Drug Formulation.

    Science.gov (United States)

    Dohi, Masafumi; Momose, Wataru; Yamashita, Kazunari; Hakomori, Tadashi; Sato, Shusaku; Noguchi, Shuji; Terada, Katsuhide

    2017-02-01

    Manufacturing the solid dosage form of an orally administered drug requires lubrication to enhance manufacturability, ensuring that critical quality attributes such as disintegration and dissolution of the drug product are maintained during manufacture. Here, to evaluate lubrication performance during manufacture, we used terahertz attenuated total reflection (THz-ATR) spectroscopy to detect differences in the physical characteristics of the lubricated powder. We applied a simple formulation prepared by blending granulated lactose as filler with magnesium stearate as lubricant. A flat tablet was prepared using the lubricated powder to acquire sharp THz-ATR absorption peaks of the samples. First, we investigated the effects of lubricant concentration and compression pressure on preparation of the tablet and then determined the effect of the pressure applied to samples in contact with the ATR prism on sample absorption amplitude. We focused on the differences in the magnitudes of spectra at the lactose-specific frequency. Second, we conducted the dynamic lubrication process using a 120-L mixer to investigate differences in the magnitudes of absorption corresponding to the lactose-specific frequency during lubrication. In both studies, enriching the lubricated powder with a higher concentration of magnesium stearate or prolonging blending time correlated with higher magnitudes of spectra at the lactose-specific frequency. Further, in the dynamic lubrication study, the wettability and disintegration time of the tablets were compared with the absorption spectra amplitudes at the lactose-specific frequency. We conclude that THz-ATR spectroscopy is useful for detecting differences in densities caused by a change in the physical properties of lactose during lubrication.

  16. Analysis of Serum Total and Free PSA Using Immunoaffinity Depletion Coupled to SRM: Correlation with Clinical Immunoassay Tests

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Tao; Hossain, Mahmud; Schepmoes, Athena A.; Fillmore, Thomas L.; Sokoll, Lori J.; Kronewitter, Scott R.; Izmirlian, Grant; Shi, Tujin; Qian, Weijun; Leach, Robin; Thompson, Ian M.; Chan, Daniel W.; Smith, Richard D.; Kagan, Jacob; Srinivastava, Sudhir; Rodland, Karin D.; Camp, David G.

    2012-08-03

    Sandwich immunoassay is the standard technique used in clinical labs for quantifying protein biomarkers for disease detection, monitoring and therapeutic intervention. Albeit highly sensitive, the development of a specific immunoassay is rather time-consuming and associated with extremely high cost due to the requirement for paired immunoaffinity reagents of high specificity. Recently, mass spectrometry-based methods, specifically selected reaction monitoring mass spectrometry (SRM-MS), have been increasingly applied to measure low abundance biomarker candidates in tissue and biofluids, owing to high sensitivity and specificity, simplicity of assay configuration, and great multiplexing capability. In this study, we report for the first time the development of immunoaffinity depletion-based workflows and SRM-MS assays that enable sensitive and accurate quantification of total and free prostate-specific antigen (PSA) in serum without the requirement for specific PSA antibodies. With stable isotope dilution and external calibration, low ng/mL level detection of both total and free PSA was consistently achieved in both PSA-spiked female serum samples and actual patient serum samples. Moreover, comparison of the results obtained when SRM PSA assays and conventional immunoassays were applied to the same samples showed very good correlation (R2 values ranging from 0.90 to 0.99) in several independent clinical serum sample sets, including a set of 33 samples assayed in a blinded test. These results demonstrate that the workflows and SRM assays developed here provide an attractive alternative for reliably measuring total and free PSA in human blood. Furthermore, simultaneous measurement of free and total PSA and many other biomarkers can be performed in a single analysis using high-resolution liquid chromatographic separation coupled with SRM-MS.

  17. Sample preparation for total reflection X-ray fluorescence analysis using resist pattern technique

    Science.gov (United States)

    Tsuji, K.; Yomogita, N.; Konyuba, Y.

    2018-06-01

    A circular resist pattern layer with a diameter of 9 mm was prepared on a glass substrate (26 mm × 76 mm; 1.5 mm thick) for total reflection X-ray fluorescence (TXRF) analysis. The parallel cross pattern was designed with a wall thickness of 10 μm, an interval of 20 μm, and a height of 1.4 or 0.8 μm. This additional resist layer did not significantly increase background intensity on the XRF peaks in TXRF spectra. Dotted residue was obtained from a standard solution (10 μL) containing Ti, Cr, Ni, Pb, and Ga, each at a final concentration of 10 ppm, on a normal glass substrate with a silicone coating layer. The height of the residue was more than 100 μm, where self-absorption in the large residue affected TXRF quantification (intensity relative standard deviation (RSD): 12-20%). In contrast, from a droplet composed of a small volume of solution dropped and cast on the resist pattern structure, the obtained residue was not completely film but a film-like residue with a thickness less than 1 μm, where self-absorption was not a serious problem. In the end, this sample preparation was demonstrated to improve TXRF quantification (intensity RSD: 2-4%).

  18. All-optical microscope autofocus based on an electrically tunable lens and a totally internally reflected IR laser.

    Science.gov (United States)

    Bathe-Peters, M; Annibale, P; Lohse, M J

    2018-02-05

    Microscopic imaging at high spatial-temporal resolution over long time scales (minutes to hours) requires rapid and precise stabilization of the microscope focus. Conventional and commercial autofocus systems are largely based on piezoelectric stages or mechanical objective actuators. Objective to sample distance is either measured by image analysis approaches or by hardware modules measuring the intensity of reflected infrared light. We propose here a truly all-optical microscope autofocus taking advantage of an electrically tunable lens and a totally internally reflected infrared probe beam. We implement a feedback-loop based on the lateral position of a totally internally reflected infrared laser on a quadrant photodetector, as an indicator of the relative defocus. We show here how to treat the combined contributions due to mechanical defocus and deformation of the tunable lens. As a result, the sample can be kept in focus without any mechanical movement, at rates up to hundreds of Hertz. The device requires only reflective optics and can be implemented at a fraction of the cost required for a comparable piezo-based actuator.

  19. Determination of diffusible and total hydrogen concentration in coated and uncoated steel

    Energy Technology Data Exchange (ETDEWEB)

    Mabho, Nonhlangabezo

    2010-09-23

    The new trend in the steel industry demands thin, flexible, high strength steels with low internal embrittlement. It is a well known fact that the atomic hydrogen which is picked up during production, fabrication and service embrittles the steel. This has led to an extensive research towards the improvement of the quality of metallic materials by focusing on total and diffusible hydrogen concentrations which are responsible for hydrogen embrittlement. Since the internal embrittlement cannot be foreseen, the concentrations of diffusible hydrogen work as indicators while the total hydrogen characterizes the absorbed quantities and quality of that particular product. To meet these requirements, the analytical chemistry methods which include the already existing carrier gas melt (fusion) extraction methods that use infrared and thermal conductivity for total hydrogen detection were applied. The newly constructed carrier gas thermal desorption mass spectroscopy was applied to monitor the diffusible concentration at specific temperatures and desorption rates of hydrogen which will contribute towards the quality of materials during service. The TDMS method also involved the characterization of the energy quantity (activation energy) required by hydrogen to be removed from traps of which irreversible traps are preferred because they enhance the stability of the product by inhibiting the mobility of hydrogen which is detrimental to the metallic structures. The instrumentation for TDMS is quite simple, compact, costs less and applicable to routine analysis. To determine total and diffusible hydrogen, the influence of the following processes: chemical and mechanical zinc coating removal, sample cleaning with organic solvents, conditions for hydrogen absorption by electrolytic hydrogen charging, conditions of hydrogen desorption by storing the sample at room temperature, solid CO{sub 2} and at temperatures of the drier was analysed. The contribution of steel alloys towards

  20. Impact of total laryngectomy on return to work.

    Science.gov (United States)

    Costa, Jose Miguel; López, Montserrat; García, Jacinto; León, Xavier; Quer, Miquel

    Total laryngectomy is one of the most mutilating oncological operations. There are no specific studies evaluating return to work after this surgery. A cross-sectional study was performed on a sample of 116 laryngectomized patients who were disease- free and had a minimum follow-up of 2 years from total laryngectomy. A survey was conducted to find out their employment situation before and after surgery. At the time of surgery, 62 (53%) were working, 40 (35%) were retired and 14 (12%) were in a disability situation. 60% had professions with low qualification requirements, the largest group being construction workers. Of the 62 patients active at the time of total laryngectomy, 29 became inactive and 33 (53%) maintained their work activity. The most important factors in maintaining work activity were the level of professional qualification and the method of vocal rehabilitation. Eighty percent of the patients with high-intermediate qualification maintained their jobs, compared to 35% of those with low professional qualifications (Pde Otorrinolaringología y Cirugía de Cabeza y Cuello. All rights reserved.

  1. Total arsenic in selected food samples from Argentina: Estimation of their contribution to inorganic arsenic dietary intake.

    Science.gov (United States)

    Sigrist, Mirna; Hilbe, Nandi; Brusa, Lucila; Campagnoli, Darío; Beldoménico, Horacio

    2016-11-01

    An optimized flow injection hydride generation atomic absorption spectroscopy (FI-HGAAS) method was used to determine total arsenic in selected food samples (beef, chicken, fish, milk, cheese, egg, rice, rice-based products, wheat flour, corn flour, oats, breakfast cereals, legumes and potatoes) and to estimate their contributions to inorganic arsenic dietary intake. The limit of detection (LOD) and limit of quantification (LOQ) values obtained were 6μgkg(-)(1) and 18μgkg(-)(1), respectively. The mean recovery range obtained for all food at a fortification level of 200μgkg(-)(1) was 85-110%. Accuracy was evaluated using dogfish liver certified reference material (DOLT-3 NRC) for trace metals. The highest total arsenic concentrations (in μgkg(-)(1)) were found in fish (152-439), rice (87-316) and rice-based products (52-201). The contribution to inorganic arsenic (i-As) intake was calculated from the mean i-As content of each food (calculated by applying conversion factors to total arsenic data) and the mean consumption per day. The primary contributors to inorganic arsenic intake were wheat flour, including its proportion in wheat flour-based products (breads, pasta and cookies), followed by rice; both foods account for close to 53% and 17% of the intake, respectively. The i-As dietary intake, estimated as 10.7μgday(-)(1), was significantly lower than that from drinking water in vast regions of Argentina. Copyright © 2016 Elsevier Ltd. All rights reserved.

  2. Estimation of total error in DWPF reported radionuclide inventories. Revision 1

    International Nuclear Information System (INIS)

    Edwards, T.B.

    1995-01-01

    The Defense Waste Processing Facility (DWPF) at the Savannah River Site is required to determine and report the radionuclide inventory of its glass product. For each macro-batch, the DWPF will report both the total amount (in curies) of each reportable radionuclide and the average concentration (in curies/gram of glass) of each reportable radionuclide. The DWPF is to provide the estimated error of these reported values of its radionuclide inventory as well. The objective of this document is to provide a framework for determining the estimated error in DWPF's reporting of these radionuclide inventories. This report investigates the impact of random errors due to measurement and sampling on the total amount of each reportable radionuclide in a given macro-batch. In addition, the impact of these measurement and sampling errors and process variation are evaluated to determine the uncertainty in the reported average concentrations of radionuclides in DWPF's filled canister inventory resulting from each macro-batch

  3. Glycan characterization of the NIST RM monoclonal antibody using a total analytical solution: From sample preparation to data analysis.

    Science.gov (United States)

    Hilliard, Mark; Alley, William R; McManus, Ciara A; Yu, Ying Qing; Hallinan, Sinead; Gebler, John; Rudd, Pauline M

    Glycosylation is an important attribute of biopharmaceutical products to monitor from development through production. However, glycosylation analysis has traditionally been a time-consuming process with long sample preparation protocols and manual interpretation of the data. To address the challenges associated with glycan analysis, we developed a streamlined analytical solution that covers the entire process from sample preparation to data analysis. In this communication, we describe the complete analytical solution that begins with a simplified and fast N-linked glycan sample preparation protocol that can be completed in less than 1 hr. The sample preparation includes labelling with RapiFluor-MS tag to improve both fluorescence (FLR) and mass spectral (MS) sensitivities. Following HILIC-UPLC/FLR/MS analyses, the data are processed and a library search based on glucose units has been included to expedite the task of structural assignment. We then applied this total analytical solution to characterize the glycosylation of the NIST Reference Material mAb 8761. For this glycoprotein, we confidently identified 35 N-linked glycans and all three major classes, high mannose, complex, and hybrid, were present. The majority of the glycans were neutral and fucosylated; glycans featuring N-glycolylneuraminic acid and those with two galactoses connected via an α1,3-linkage were also identified.

  4. Analysis of spatial patterns informs community assembly and sampling requirements for Collembola in forest soils

    Science.gov (United States)

    Dirilgen, Tara; Juceviča, Edite; Melecis, Viesturs; Querner, Pascal; Bolger, Thomas

    2018-01-01

    The relative importance of niche separation, non-equilibrial and neutral models of community assembly has been a theme in community ecology for many decades with none appearing to be applicable under all circumstances. In this study, Collembola species abundances were recorded over eleven consecutive years in a spatially explicit grid and used to examine (i) whether observed beta diversity differed from that expected under conditions of neutrality, (ii) whether sampling points differed in their relative contributions to overall beta diversity, and (iii) the number of samples required to provide comparable estimates of species richness across three forest sites. Neutrality could not be rejected for 26 of the forest by year combinations. However, there is a trend toward greater structure in the oldest forest, where beta diversity was greater than predicted by neutrality on five of the eleven sampling dates. The lack of difference in individual- and sample-based rarefaction curves also suggests randomness in the system at this particular scale of investigation. It seems that Collembola communities are not spatially aggregated and assembly is driven primarily by neutral processes particularly in the younger two sites. Whether this finding is due to small sample size or unaccounted for environmental variables cannot be determined. Variability between dates and sites illustrates the potential of drawing incorrect conclusions if data are collected at a single site and a single point in time.

  5. Comparative study of radiometric and calorimetric methods for total hemispherical emissivity measurements

    Science.gov (United States)

    Monchau, Jean-Pierre; Hameury, Jacques; Ausset, Patrick; Hay, Bruno; Ibos, Laurent; Candau, Yves

    2018-05-01

    Accurate knowledge of infrared emissivity is important in applications such as surface temperature measurements by infrared thermography or thermal balance for building walls. A comparison of total hemispherical emissivity measurement was performed by two laboratories: the Laboratoire National de Métrologie et d'Essais (LNE) and the Centre d'Études et de Recherche en Thermique, Environnement et Systèmes (CERTES). Both laboratories performed emissivity measurements on four samples, chosen to cover a large range of emissivity values and angular reflectance behaviors. The samples were polished aluminum (highly specular, low emissivity), bulk PVC (slightly specular, high emissivity), sandblasted aluminum (diffuse surface, medium emissivity), and aluminum paint (slightly specular surface, medium emissivity). Results obtained using five measurement techniques were compared. LNE used a calorimetric method for direct total hemispherical emissivity measurement [1], an absolute reflectometric measurement method [2], and a relative reflectometric measurement method. CERTES used two total hemispherical directional reflectometric measurement methods [3, 4]. For indirect techniques by reflectance measurements, the total hemispherical emissivity values were calculated from directional hemispherical reflectance measurement results using spectral integration when required and directional to hemispherical extrapolation. Results were compared, taking into account measurement uncertainties; an added uncertainty was introduced to account for heterogeneity over the surfaces of the samples and between samples. All techniques gave large relative uncertainties for a low emissive and very specular material (polished aluminum), and results were quite scattered. All the indirect techniques by reflectance measurement gave results within ±0.01 for a high emissivity material. A commercial aluminum paint appears to be a good candidate for producing samples with medium level of emissivity

  6. Chromium 51 EDTA/technetium 99m MDP plasma ratio to measure total skeletal function

    Energy Technology Data Exchange (ETDEWEB)

    Nisbet, A.P.; Edwards, S.; Lazarus, C.R.; Malamitsi, J.; Maisey, M.N.; Mashiter, G.D.; Winn, P.J. (Guy' s Hospital, London (UK))

    1984-08-01

    A method is described for the quantitation of total skeletal activity during bone scans. The method requires a single plasma sample only, taken at the time of imaging. The ratio of % injected dose of /sup 51/Cr EDTA to that of /sup 99/Tcsup(m) MDP is calculated from this sample following combined injection of the two radiopharmaceuticals. The /sup 51/Cr EDTA level corrects for the glomerular filtration of /sup 99/Tcsup(m) MDP. Using this method, which only requires a gamma counter, significant differences from normal controls have been shown in patients with osteomalacia, renal osteodystrophy, Paget's disease and hypercalcaemia. The method provides routine quantitative data to add to the imaging information in the bone scan.

  7. 40 CFR 141.23 - Inorganic chemical sampling and analytical requirements.

    Science.gov (United States)

    2010-07-01

    ... may allow a groundwater system to reduce the sampling frequency to annually after four consecutive... this section. (a) Monitoring shall be conducted as follows: (1) Groundwater systems shall take a... system shall take each sample at the same sampling point unless conditions make another sampling point...

  8. Blood gas sample spiking with total parenteral nutrition, lipid emulsion, and concentrated dextrose solutions as a model for predicting sample contamination based on glucose result.

    Science.gov (United States)

    Jara-Aguirre, Jose C; Smeets, Steven W; Wockenfus, Amy M; Karon, Brad S

    2018-05-01

    Evaluate the effects of blood gas sample contamination with total parenteral nutrition (TPN)/lipid emulsion and dextrose 50% (D50) solutions on blood gas and electrolyte measurement; and determine whether glucose concentration can predict blood gas sample contamination with TPN/lipid emulsion or D50. Residual lithium heparin arterial blood gas samples were spiked with TPN/lipid emulsion (0 to 15%) and D50 solutions (0 to 2.5%). Blood gas (pH, pCO2, pO2), electrolytes (Na+, K+ ionized calcium) and hemoglobin were measured with a Radiometer ABL90. Glucose concentration was measured in separated plasma by Roche Cobas c501. Chart review of neonatal blood gas results with glucose >300 mg/dL (>16.65 mmol/L) over a seven month period was performed to determine whether repeat (within 4 h) blood gas results suggested pre-analytical errors in blood gas results. Results were used to determine whether a glucose threshold could predict contamination resulting in blood gas and electrolyte results with greater than laboratory-defined allowable error. Samples spiked with 5% or more TPN/lipid emulsion solution or 1% D50 showed glucose concentration >500 mg/dL (>27.75 mmol/L) and produced blood gas (pH, pO 2 , pCO 2 ) results with greater than laboratory-defined allowable error. TPN/lipid emulsion, but not D50, produced greater than allowable error in electrolyte (Na + ,K + ,Ca ++ ,Hb) results at these concentrations. Based on chart review of 144 neonatal blood gas results with glucose >250 mg/dL received over seven months, four of ten neonatal intensive care unit (NICU) patients with glucose results >500 mg/dL and repeat blood gas results within 4 h had results highly suggestive of pre-analytical error. Only 3 of 36 NICU patients with glucose results 300-500 mg/dL and repeat blood gas results within 4 h had clear pre-analytical errors in blood gas results. Glucose concentration can be used as an indicator of significant blood sample contamination with either TPN

  9. Implications of Microwave Holography Using Minimum Required Frequency Samples for Weakly- and Strongly-Scattering Indications

    Science.gov (United States)

    Fallahpour, M.; Case, J. T.; Kharkovsky, S.; Zoughi, R.

    2010-01-01

    Microwave imaging techniques, an integral component of nondestructive testing and evaluation (NDTE), have received significant attention in the past decade. These techniques have included the implementation of synthetic aperture focusing (SAF) algorithms for obtaining high spatial resolution images. The next important step in these developments is the implementation of 3-D holographic imaging algorithms. These are well-known wideband imaging technique requiring a swept-frequency (i.e., wideband), which unlike SAF that is a single frequency technique, are not easily performed on a real-time basis. This is due to the fact that a significant number of data points (in the frequency domain) must be obtained within the frequency band of interest. This not only makes for a complex imaging system design, it also significantly increases the image-production time. Consequently in an attempt to reduce the measurement time and system complexity, an investigation was conducted to determine the minimum required number of frequency samples needed to image a specific object while preserving a desired maximum measurement range and range resolution. To this end the 3-D holographic algorithm was modified to use properlyinterpolated frequency data. Measurements of the complex reflection coefficient for several samples were conducted using a swept-frequency approach. Subsequently, holographical images were generated using data containing a relatively large number of frequency samples and were compared with images generated by the reduced data set data. Quantitative metrics such as average, contrast, and signal-to-noise ratio were used to evaluate the quality of images generated using reduced data sets. Furthermore, this approach was applied to both weakly- and strongly-scattering indications. This paper presents the methods used and the results of this investigation.

  10. On-line technique for preparingand measuring stable carbon isotopeof total dissolved inorganic carbonin water samples ( d13CTDIC

    Directory of Open Access Journals (Sweden)

    S. Inguaggiato

    2005-06-01

    Full Text Available A fast and completely automated procedure is proposed for the preparation and determination of d13C of total inorganic carbon dissolved in water ( d13CTDIC. This method is based on the acidification of water samples transforming the whole dissolved inorganic carbon species into CO2. Water samples are directly injected by syringe into 5.9 ml vials with screw caps which have a pierciable rubber septum. An Analytical Precision «Carbonate Prep System» was used both to flush pure helium into the vials and to automatically dispense a fixed amount of H3PO4. Full-equilibrium conditions between produced CO2 and water are reached at a temperature of 70°C (± 0.1°C in less than 24 h. Carbon isotope ratios (13C/ 12C were measured on an AP 2003 continuous flow mass spectrometer, connected on-line with the injection system. The precision and reproducibility of the proposed method was tested both on aqueous standard solutions prepared using Na2CO3 with d13C=-10.78 per mil versus PDB (1 s= 0.08, n = 11, and at five different concentrations (2, 3, 4, 5 and 20 mmol/l and on more than thirty natural samples. Mean d13CTDIC on standard solution samples is ?10.89 < per mil versus PDB (1 s= 0.18, n = 50, thus revealing both a good analytical precision and reproducibility. A comparison between average d13CTDIC values on a quadruplicate set of natural samples and those obtained following the chemical and physical stripping method highlights a good agreement between the two analytical methods.

  11. 30 CFR 90.201 - Sampling; general requirements.

    Science.gov (United States)

    2010-07-01

    ... operational during the entire shift or for 8 hours, whichever time is less. (c) Upon request from the District... respirable dust samples of the concentration of respirable dust in the active workings of the mine as... of the normal working position; or (3) At a location that represents the maximum concentration of...

  12. Standard test method for determination of uranium or plutonium isotopic composition or concentration by the total evaporation method using a thermal ionization mass spectrometer

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2007-01-01

    1.1 This method describes the determination of the isotopic composition and/or the concentration of uranium and plutonium as nitrate solutions by the thermal ionization mass spectrometric (TIMS) total evaporation method. Purified uranium or plutonium nitrate solutions are loaded onto a degassed metal filament and placed in the mass spectrometer. Under computer control, ion currents are generated by heating of the filament(s). The ion beams are continually measured until the sample is exhausted. The measured ion currents are integrated over the course of the run, and normalized to a reference isotope ion current to yield isotopic ratios. 1.2 In principle, the total evaporation method should yield isotopic ratios that do not require mass bias correction. In practice, some samples may require this bias correction. When compared to the conventional TIMS method, the total evaporation method is approximately two times faster, improves precision from two to four fold, and utilizes smaller sample sizes. 1.3 The tot...

  13. Determination Total Phosphour of Maize Plant Samples by Continuous Flow Analyzer in Comparison with Vanadium Molybdate Yellow Colorimetric Method

    OpenAIRE

    LIU Yun-xia; WEN Yun-jie; HUANG Jin-li; LI Gui-hua; CHAI Xiao; WANG Hong

    2015-01-01

    The vanadium molybdate yellow colorimetric method(VMYC method) is regarded as one of conventional methods for determining total phosphorus(P) in plants, but it is time consuming procedure. Continuous flow analyzer(CFA) is a fluid stream segmentation technique with air segments. It is used to measure P concentration based on the molybdate-antimony-ascorbic acid method of Murphy and Riley. Sixty nine of maize plant samples were selected and digested with H2SO4-H2O2. P concentrations in the dige...

  14. Planetary Protection Requirements for Mars Sample Return Missions: Recommendations from a 2009 NRC Report

    Science.gov (United States)

    Race, Margaret; Farmer, Jack

    A 2009 report by the National Research Council (NRC) reviewed a previous study on Mars Sample Return (1997) and provided updated recommendations for future sample return mis-sions based on our current understanding about Mars and its biological potential, as well as advances in technology and analytical capabilities. The committee* made 12 specific recommen-dations that fall into three general categories—one related to current scientific understanding, ten based on changes in the technical and/or policy environment, and one aimed at public com-munication. Substantive changes from the 1997 report relate mainly to protocols and methods, technology and infrastructure, and general oversight. This presentation provides an overview of the 2009 report and its recommendations and analyzes how they may impact mission designs and plans. The full report, Assessment of Planetary Protection Requirements for Mars Sample Return Missions is available online at: http://www.nap.edu/catalog.php?recordi d = 12576 * Study participants: Jack D. Farmer, Arizona State University (chair) James F. Bell III, Cornell University Kathleen C. Benison, Central Michigan University William V. Boynton, University of Arizona Sherry L. Cady, Portland State University F. Grant Ferris, University of Toronto Duncan MacPherson, Jet Propulsion Laboratory Margaret S. Race, SETI Institute Mark H. Thiemens, University of California, San Diego Meenakshi Wadhwa, Arizona State University

  15. Optimum sample size allocation to minimize cost or maximize power for the two-sample trimmed mean test.

    Science.gov (United States)

    Guo, Jiin-Huarng; Luh, Wei-Ming

    2009-05-01

    When planning a study, sample size determination is one of the most important tasks facing the researcher. The size will depend on the purpose of the study, the cost limitations, and the nature of the data. By specifying the standard deviation ratio and/or the sample size ratio, the present study considers the problem of heterogeneous variances and non-normality for Yuen's two-group test and develops sample size formulas to minimize the total cost or maximize the power of the test. For a given power, the sample size allocation ratio can be manipulated so that the proposed formulas can minimize the total cost, the total sample size, or the sum of total sample size and total cost. On the other hand, for a given total cost, the optimum sample size allocation ratio can maximize the statistical power of the test. After the sample size is determined, the present simulation applies Yuen's test to the sample generated, and then the procedure is validated in terms of Type I errors and power. Simulation results show that the proposed formulas can control Type I errors and achieve the desired power under the various conditions specified. Finally, the implications for determining sample sizes in experimental studies and future research are discussed.

  16. Application of particle size distributions to total particulate stack samples to estimate PM2.5 and PM10 emission factors for agricultural sources

    Science.gov (United States)

    Particle size distributions (PSD) have long been used to more accurately estimate the PM10 fraction of total particulate matter (PM) stack samples taken from agricultural sources. These PSD analyses were typically conducted using a Coulter Counter with 50 micrometer aperture tube. With recent increa...

  17. Human DNA quantification and sample quality assessment: Developmental validation of the PowerQuant(®) system.

    Science.gov (United States)

    Ewing, Margaret M; Thompson, Jonelle M; McLaren, Robert S; Purpero, Vincent M; Thomas, Kelli J; Dobrowski, Patricia A; DeGroot, Gretchen A; Romsos, Erica L; Storts, Douglas R

    2016-07-01

    Quantification of the total amount of human DNA isolated from a forensic evidence item is crucial for DNA normalization prior to short tandem repeat (STR) DNA analysis and a federal quality assurance standard requirement. Previous commercial quantification methods determine the total human DNA and total human male DNA concentrations, but provide limited information about the condition of the DNA sample. The PowerQuant(®) System includes targets for quantification of total human and total human male DNA as well as targets for evaluating whether the human DNA is degraded and/or PCR inhibitors are present in the sample. A developmental validation of the PowerQuant(®) System was completed, following SWGDAM Validation Guidelines, to evaluate the assay's specificity, sensitivity, precision and accuracy, as well as the ability to detect degraded DNA or PCR inhibitors. In addition to the total human DNA and total human male DNA concentrations in a sample, data from the degradation target and internal PCR control (IPC) provide a forensic DNA analyst meaningful information about the quality of the isolated human DNA and the presence of PCR inhibitors in the sample that can be used to determine the most effective workflow and assist downstream interpretation. Copyright © 2016 The Author(s). Published by Elsevier Ireland Ltd.. All rights reserved.

  18. Determination Total Phosphour of Maize Plant Samples by Continuous Flow Analyzer in Comparison with Vanadium Molybdate Yellow Colorimetric Method

    Directory of Open Access Journals (Sweden)

    LIU Yun-xia

    2015-12-01

    Full Text Available The vanadium molybdate yellow colorimetric method(VMYC method is regarded as one of conventional methods for determining total phosphorus(P in plants, but it is time consuming procedure. Continuous flow analyzer(CFA is a fluid stream segmentation technique with air segments. It is used to measure P concentration based on the molybdate-antimony-ascorbic acid method of Murphy and Riley. Sixty nine of maize plant samples were selected and digested with H2SO4-H2O2. P concentrations in the digests were determined by CFA and VMYC method, respectively. The t test found that there was no any significant difference of the plant P contents measured by the CFA and the VMYC method. A linear equation could best describe their relationship: Y(CFA-P=0.927X(VMYC-P-0.002. The Pearson's correlation coefficient was 0.985 with a significance level(n=69, P<0.01. The CFA method for plant P measurement had a high precision with relative standard deviation(RSD less than 1.5%. It is suggested that the CFA based on Murphy and Riley colorimetric detection can be used to determinate total plant P in the digests solutions with H2SO4-H2O2. The CFA method is labor saving and can handle large numbers of samples. The human error in mixing with other operations is reduced to a great extent.

  19. KUALITAS MIKROBIOLOGI NASI JINGGO BERDASARKAN ANGKA LEMPENG TOTAL, COLIFORM TOTAL DAN KANDUNGAN ESCHERICHIA COLI

    Directory of Open Access Journals (Sweden)

    Ni Luh Payastiti Yunita

    2010-06-01

    Full Text Available Inadequate quality of food products that do not meet standard quality may lead to food poisoning cases and become a concern in public health sector. Nasi Jinggo is a small amount of cooked rice with little bit fried tempe, shredded spicy chicken, traditional made chili sauce that is packed with banana leaves, and all the cooking process usually done traditionally. Nasi jinggo is sold at night by street vendor with price ranged from Rp. 1.500,- to Rp. 2.000,- per package. The study was a quantitative descriptive study with cross-sectional design that was aimed to identify the microbiology quality of nasi jinggo that were sold in Denpasar Selatan area. From 48 population of nasi jinggo street vendor, 23 vendor was taken as samples. The microbiology quality being assessed was Total Plate Count (TPC, Total Coliform with MPN method and Escherichia coli content with Eosin Methylene Blue Agar as medium. Laboratory analysis showed that only 21,7% sample that met TPC standard with average value of 2,3 x 107 CFU/gram sample, only 8,7% that met Total Coliform standard with average value of 1,4 x 105 MPN/100 gram sample and 52,2% sample that met E. coli content standard with average value is 2,6 x 102 MPN/100 gram sample. It is recommended to the government to do quality check towards nasi jinggo in a regular basis as well as to provide education and assistance to nasi jinggo street vendors in order to improve the microbiology quality of food product and ensure food safety to the consumer.

  20. Cemaran Mikroba Escherichia coli dan Total Bakteri Koliform pada Air Minum Isi Ulang

    Directory of Open Access Journals (Sweden)

    Rolan Sudirman Pakpahan

    2015-05-01

    there is no guarantee that refill drinking water quality meets any requirement every time. Results of refill drinking water sample in Kupang City in 2013 showed the water was 37.5% contaminated by microbes. This study aimed to analyze microbial contamination and determine determinants of Escherichia coli (E. coli and total Coliform on refill drinking water. This study used cross sectional design on January - March 2015. The population was 51 depots determined using total sampling technique. Data analysis was conducted in univariate, bivariate using simple logistic regression test and multivariate using multiple logistic regression test. Results showed drinking water contaminated by microbes worth 26 depots (51%, by E. coli 33.33% and by total Coliform 51%. Microbial contamination determinants using bivariate were knowledge (p value = 0.01 and behavior of operator (p value = 0.05. Meanwhile, microbial contamination determinants conducting multivariate were knowledge (p value = 0.026, hygiene of operator (p value = 0.05 and depot sanitation (p value = 0.044. Most dominating variables influencing microbial contamination are knowledge, operator’s hygiene and depot sanitation.

  1. Incidence of Severe Osteonecrosis Requiring Total Joint Arthroplasty in Children and Young Adults Treated for Leukemia or Lymphoma

    DEFF Research Database (Denmark)

    Niinimäki, Riitta; Hansen, Lene Mølgaard; Niinimäki, Tuukka

    2013-01-01

    diagnosis codes given before the age of 40 were also retrieved. Results: The estimated cumulative incidence of TJA was 4.5% at 20 years for patients treated for chronic myeloid leukemia, followed by 2.1% for patients treated for acute myeloid leukemia. It was considerably lower in patients with acute...... the age of 10 (HR=24; 95% CI: 3.1-176 and HR=26; 95% CI: 3.6-192 respectively). Conclusion: The incidence of ON requiring TJA was highest among patients with myeloid leukemias and lowest in patients treated for ALL. Allo-SCT and age ≥10 years at diagnosis were the most important risk factors......Purpose: The population-based incidence of severe osteonecrosis (ON) necessitating total joint arthroplasty (TJA) in patients with hematological cancer is unknown. This study assessed the incidence of ON requiring primary TJA in children and young adults treated for leukemia or lymphoma. Methods...

  2. Probabilistic Requirements (Partial) Verification Methods Best Practices Improvement. Variables Acceptance Sampling Calculators: Derivations and Verification of Plans. Volume 1

    Science.gov (United States)

    Johnson, Kenneth L.; White, K, Preston, Jr.

    2012-01-01

    The NASA Engineering and Safety Center was requested to improve on the Best Practices document produced for the NESC assessment, Verification of Probabilistic Requirements for the Constellation Program, by giving a recommended procedure for using acceptance sampling by variables techniques. This recommended procedure would be used as an alternative to the potentially resource-intensive acceptance sampling by attributes method given in the document. This document contains the outcome of the assessment.

  3. Highly Reproducible Automated Proteomics Sample Preparation Workflow for Quantitative Mass Spectrometry.

    Science.gov (United States)

    Fu, Qin; Kowalski, Michael P; Mastali, Mitra; Parker, Sarah J; Sobhani, Kimia; van den Broek, Irene; Hunter, Christie L; Van Eyk, Jennifer E

    2018-01-05

    Sample preparation for protein quantification by mass spectrometry requires multiple processing steps including denaturation, reduction, alkylation, protease digestion, and peptide cleanup. Scaling these procedures for the analysis of numerous complex biological samples can be tedious and time-consuming, as there are many liquid transfer steps and timed reactions where technical variations can be introduced and propagated. We established an automated sample preparation workflow with a total processing time for 96 samples of 5 h, including a 2 h incubation with trypsin. Peptide cleanup is accomplished by online diversion during the LC/MS/MS analysis. In a selected reaction monitoring (SRM) assay targeting 6 plasma biomarkers and spiked β-galactosidase, mean intraday and interday cyclic voltammograms (CVs) for 5 serum and 5 plasma samples over 5 days were samples repeated on 3 separate days had total CVs below 20%. Similar results were obtained when the workflow was transferred to a second site: 93% of peptides had CVs below 20%. An automated trypsin digestion workflow yields uniformly processed samples in less than 5 h. Reproducible quantification of peptides was observed across replicates, days, instruments, and laboratory sites, demonstrating the broad applicability of this approach.

  4. Label-Free Quantitative Analysis of Mitochondrial Proteomes Using the Multienzyme Digestion-Filter Aided Sample Preparation (MED-FASP) and "Total Protein Approach".

    Science.gov (United States)

    Wiśniewski, Jacek R

    2017-01-01

    Determination of proteome composition and measuring of changes in protein titers provide important information with a substantial value for studying mitochondria.This chapter describes a workflow for the quantitative analysis of mitochondrial proteome with a focus on sample preparation and quantitative analysis of the data. The workflow involves the multienzyme digestion-filter aided sample preparation (MED-FASP) protocol enabling efficient extraction of proteins and high rate of protein-to-peptide conversion. Consecutive protein digestion with Lys C and trypsin enables generation of peptide fractions with minimal overlap, largely increases the number of identified proteins, and extends their sequence coverage. Abundances of proteins identified by multiple peptides can be assessed by the "Total Protein Approach."

  5. Task 16 -- Sampling and analysis at the Vortec vitrification facility in Paducah, Kentucky. Semi-annual report, April 1--September 30, 1997

    International Nuclear Information System (INIS)

    Laudal, D.L.; Lilemoen, C.M.; Hurley, J.P.; Ness, S.R.; Stepan, D.J.; Thompson, J.S.

    1997-05-01

    The Vortec Cyclone Melting System (CMS reg-sign) facility, to be located at the US Department of Energy (DOE) Paducah Gaseous Diffusion Plant, is designed to treat soil contaminated with low levels of heavy metals and radioactive elements, as well as organic waste. To assure that costs of sampling and analysis are contained, Vortec and the DOE Federal Energy Technology Center (FETC) have decided that initially the primary focus of the sampling activities will be on meeting permitting requirements of the state of Kentucky. Therefore, sampling will be limited to the feedstock entering the system, and the glass, flue gas, and water leaving the system. The authors provide suggestions for optional sampling points and procedures in case there is later interest in operations or mass balance data. The permits do not require speciation of the materials in the effluents, only opacity, total radioactivity, total particulate, and total HCl emissions for the gaseous emissions and total radioactivity in the water and solid products. In case future testing to support operations or mass balances is required, the authors include in this document additional information on the analyses of some species of interest. They include heavy metals (RCRA [Resource Conservation and Recovery Act] and Cu and Ni), radionuclides (Th 230 , U 235 , Tc 99 , Cs 137 , and Pu 239 ), and dioxins/furans

  6. Integrated sampling and analysis plan for samples measuring >10 mrem/hour

    International Nuclear Information System (INIS)

    Haller, C.S.

    1992-03-01

    This integrated sampling and analysis plan was prepared to assist in planning and scheduling of Hanford Site sampling and analytical activities for all waste characterization samples that measure greater than 10 mrem/hour. This report also satisfies the requirements of the renegotiated Interim Milestone M-10-05 of the Hanford Federal Facility Agreement and Consent Order (the Tri-Party Agreement). For purposes of comparing the various analytical needs with the Hanford Site laboratory capabilities, the analytical requirements of the various programs were normalized by converting required laboratory effort for each type of sample to a common unit of work, the standard analytical equivalency unit (AEU). The AEU approximates the amount of laboratory resources required to perform an extensive suite of analyses on five core segments individually plus one additional suite of analyses on a composite sample derived from a mixture of the five core segments and prepare a validated RCRA-type data package

  7. Total Effective Xenoestrogen Burden in Serum Samples and Risk for Breast Cancer in a Population-Based Multicase–Control Study in Spain

    Science.gov (United States)

    Pastor-Barriuso, Roberto; Fernández, Mariana F.; Castaño-Vinyals, Gemma; Whelan, Denis; Pérez-Gómez, Beatriz; Llorca, Javier; Villanueva, Cristina M.; Guevara, Marcela; Molina-Molina, José-Manuel; Artacho-Cordón, Francisco; Barriuso-Lapresa, Laura; Tusquets, Ignasi; Dierssen-Sotos, Trinidad; Aragonés, Nuria; Olea, Nicolás; Kogevinas, Manolis; Pollán, Marina

    2016-01-01

    Background: Most studies on endocrine-disrupting chemicals and breast cancer have focused on single compounds and have produced inconclusive findings. Objectives: We assessed the combined estrogenic effects of mixtures of xenoestrogens in serum and their relationship to breast cancer risk. Methods: A total of 186 incident pretreatment breast cancer cases and 196 frequency-matched controls were randomly sampled from a large population-based multicase–control study in Spain. The total effective xenoestrogen burden attributable to organohalogenated xenoestrogens (TEXB-α) and endogenous hormones and more polar xenoestrogens (TEXB-β) was determined in serum samples using high-performance liquid chromatography and E-Screen bioassay. Odds ratios for breast cancer comparing tertiles of serum TEXB-α and TEXB-β were estimated using logistic models, and smooth risk trends were obtained using spline models. Results: Cases had higher geometric mean TEXB-α and TEXB-β levels (8.32 and 9.94 Eeq pM/mL, respectively) than controls (2.99 and 5.96 Eeq pM/mL, respectively). The fully adjusted odds ratios for breast cancer (95% confidence intervals) comparing the second and third tertiles of TEXB-α with the first tertile were 1.77 (0.76, 4.10) and 3.45 (1.50, 7.97), respectively, and those for TEXB-β were 2.35 (1.10, 5.03) and 4.01 (1.88, 8.56), respectively. A steady increase in risk was evident across all detected TEXB-α levels and a sigmoidal trend was observed for TEXB-β. Individual xenoestrogens showed weak and opposing associations with breast cancer risk. Conclusions: This is the first study to show a strong positive association between serum total xenoestrogen burden and breast cancer risk, highlighting the importance of evaluating xenoestrogen mixtures, rather than single compounds, when studying hormone-related cancers. Citation: Pastor-Barriuso R, Fernández MF, Castaño-Vinyals G, Whelan D, Pérez-Gómez B, Llorca J, Villanueva CM, Guevara M, Molina-Molina JM

  8. Economic Design of Acceptance Sampling Plans in a Two-Stage Supply Chain

    Directory of Open Access Journals (Sweden)

    Lie-Fern Hsu

    2012-01-01

    Full Text Available Supply Chain Management, which is concerned with material and information flows between facilities and the final customers, has been considered the most popular operations strategy for improving organizational competitiveness nowadays. With the advanced development of computer technology, it is getting easier to derive an acceptance sampling plan satisfying both the producer's and consumer's quality and risk requirements. However, all the available QC tables and computer software determine the sampling plan on a noneconomic basis. In this paper, we design an economic model to determine the optimal sampling plan in a two-stage supply chain that minimizes the producer's and the consumer's total quality cost while satisfying both the producer's and consumer's quality and risk requirements. Numerical examples show that the optimal sampling plan is quite sensitive to the producer's product quality. The product's inspection, internal failure, and postsale failure costs also have an effect on the optimal sampling plan.

  9. Impact of habitat diversity on the sampling effort required for the assessment of river fish communities and IBI

    NARCIS (Netherlands)

    Van Liefferinge, C.; Simoens, I.; Vogt, C.; Cox, T.J.S.; Breine, J.; Ercken, D.; Goethals, P.; Belpaire, C.; Meire, P.

    2010-01-01

    The spatial variation in the fish communities of four small Belgian rivers with variable habitat diversity was investigated by electric fishing to define the minimum sampling distance required for optimal fish stock assessment and determination of the Index of Biotic Integrity. This study shows that

  10. An efficient sampling approach for variance-based sensitivity analysis based on the law of total variance in the successive intervals without overlapping

    Science.gov (United States)

    Yun, Wanying; Lu, Zhenzhou; Jiang, Xian

    2018-06-01

    To efficiently execute the variance-based global sensitivity analysis, the law of total variance in the successive intervals without overlapping is proved at first, on which an efficient space-partition sampling-based approach is subsequently proposed in this paper. Through partitioning the sample points of output into different subsets according to different inputs, the proposed approach can efficiently evaluate all the main effects concurrently by one group of sample points. In addition, there is no need for optimizing the partition scheme in the proposed approach. The maximum length of subintervals is decreased by increasing the number of sample points of model input variables in the proposed approach, which guarantees the convergence condition of the space-partition approach well. Furthermore, a new interpretation on the thought of partition is illuminated from the perspective of the variance ratio function. Finally, three test examples and one engineering application are employed to demonstrate the accuracy, efficiency and robustness of the proposed approach.

  11. Determination of As(III) and total inorganic As in water samples using an on-line solid phase extraction and flow injection hydride generation atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Sigrist, Mirna; Albertengo, Antonela; Beldomenico, Horacio; Tudino, Mabel

    2011-01-01

    A simple and robust on-line sequential injection system based on solid phase extraction (SPE) coupled to a flow injection hydride generation atomic absorption spectrometer (FI-HGAAS) with a heated quartz tube atomizer (QTA) was developed and optimized for the determination of As(III) in groundwater without any kind of sample pretreatment. The method was based on the selective retention of inorganic As(V) that was carried out by passing the filtered original sample through a cartridge containing a chloride-form strong anion exchanger. Thus the most toxic form, inorganic As(III), was determined fast and directly by AsH 3 generation using 3.5 mol L -1 HCl as carrier solution and 0.35% (m/v) NaBH 4 in 0.025% NaOH as the reductant. Since the uptake of As(V) should be interfered by several anions of natural occurrence in waters, the effect of Cl - , SO 4 2- , NO 3 - , HPO 4 2- , HCO 3 - on retention was evaluated and discussed. The total soluble inorganic arsenic concentration was determined on aliquots of filtered samples acidified with concentrated HCl and pre-reduced with 5% KI-5% C 6 H 8 O 6 solution. The concentration of As(V) was calculated by difference between the total soluble inorganic arsenic and As(III) concentrations. Detection limits (LODs) of 0.5 μg L -1 and 0.6 μg L -1 for As(III) and inorganic total As, respectively, were obtained for a 500 μL sample volume. The obtained limits of detection allowed testing the water quality according to the national and international regulations. The analytical recovery for water samples spiked with As(III) ranged between 98% and 106%. The sampling throughput for As(III) determination was 60 samples h -1 . The device for groundwater sampling was especially designed for the authors. Metallic components were avoided and the contact between the sample and the atmospheric oxygen was carried to a minimum. On-field arsenic species separation was performed through the employ of a serial connection of membrane filters and

  12. Compatibility of 5-fluorouracil and total parenteral nutrition solutions.

    Science.gov (United States)

    Hardin, T C; Clibon, U; Page, C P; Cruz, A B

    1982-01-01

    The physicochemical stability and availability of 0.1% 5-fluorouracil solutions in D5W and a typical total parenteral nutrition solution (hypertonic dextrose and crystalline amino acids) were studied in both glass and Viaflex delivery systems. Serial samples collected over a 48-hour period were assayed for 5-fluorouracil concentration using a high performance liquid chromatographic technique. Changes in the pH as well as precipitate formation were also investigated. There was no reduction in the amount of 5-fluorouracil at 48 hours in either the glass or plastic system, regardless of whether the drug was added to D5W or to the total parenteral nutrition solution. No pH changes or precipitates were observed. These findings indicate that 5-fluorouracil is compatible with and available from total parenteral solutions of hypertonic dextrose and amino acid in both plastic and glass containers. Use of such a system would allow for (1) a reduction in vascular access in patients receiving both treatments and (2) continued administration of nutritional support without the requirement for additional fluid volume.

  13. Laboratory testing of rock and salt samples for determination of specific gravity and total porosity of the Zeeck No. 1 well (PD-7), Palo Duro Basin, Texas: unanalyzed data

    International Nuclear Information System (INIS)

    1984-07-01

    This report contains the specific gravity and total porosity determinations for rock and salt samples from Zeeck No. 1 Well of the Permian Basin. The laboratory test samples were measured for water content, apparent specific gravity, specific gravity of solids, total porosity and effective porosity. Specimen descriptions including specimen number, formation/group, and lithologic description as well as typical data sheets are included in the appendices. These data are preliminary. They have been neither analyzed nor evaluated

  14. Two to five repeated measurements per patient reduced the required sample size considerably in a randomized clinical trial for patients with inflammatory rheumatic diseases

    Directory of Open Access Journals (Sweden)

    Smedslund Geir

    2013-02-01

    Full Text Available Abstract Background Patient reported outcomes are accepted as important outcome measures in rheumatology. The fluctuating symptoms in patients with rheumatic diseases have serious implications for sample size in clinical trials. We estimated the effects of measuring the outcome 1-5 times on the sample size required in a two-armed trial. Findings In a randomized controlled trial that evaluated the effects of a mindfulness-based group intervention for patients with inflammatory arthritis (n=71, the outcome variables Numerical Rating Scales (NRS (pain, fatigue, disease activity, self-care ability, and emotional wellbeing and General Health Questionnaire (GHQ-20 were measured five times before and after the intervention. For each variable we calculated the necessary sample sizes for obtaining 80% power (α=.05 for one up to five measurements. Two, three, and four measures reduced the required sample sizes by 15%, 21%, and 24%, respectively. With three (and five measures, the required sample size per group was reduced from 56 to 39 (32 for the GHQ-20, from 71 to 60 (55 for pain, 96 to 71 (73 for fatigue, 57 to 51 (48 for disease activity, 59 to 44 (45 for self-care, and 47 to 37 (33 for emotional wellbeing. Conclusions Measuring the outcomes five times rather than once reduced the necessary sample size by an average of 27%. When planning a study, researchers should carefully compare the advantages and disadvantages of increasing sample size versus employing three to five repeated measurements in order to obtain the required statistical power.

  15. The nTOF Total Absorption Calorimeter for neutron capture measurements at CERN

    International Nuclear Information System (INIS)

    Guerrero, C.; Abbondanno, U.; Aerts, G.; Alvarez, H.; Alvarez-Velarde, F.; Andriamonje, S.; Andrzejewski, J.; Assimakopoulos, P.; Audouin, L.; Badurek, G.; Baumann, P.; Becvar, F.; Berthoumieux, E.; Calvino, F.; Calviani, M.; Cano-Ott, D.; Capote, R.; Carrapico, C.; Cennini, P.; Chepel, V.

    2009-01-01

    The n T OF Collaboration has built and commissioned a high-performance detector for (n,γ) measurements called the Total Absorption Calorimeter (TAC). The TAC was especially designed for measuring neutron capture cross-sections of low-mass and/or radioactive samples with the accuracy required for nuclear technology and stellar nucleosynthesis. We present a detailed description of the TAC and discuss its overall performance in terms of energy and time resolution, background discrimination, detection efficiency and neutron sensitivity.

  16. Pumping time required to obtain tube well water samples with aquifer characteristic radon concentrations

    International Nuclear Information System (INIS)

    Ricardo, Carla Pereira; Oliveira, Arno Heeren de

    2011-01-01

    Radon is an inert noble gas, which comes from the natural radioactive decay of uranium and thorium in soil, rock and water. Radon isotopes emanated from radium-bearing grains of a rock or soil are released into the pore space. Radon that reaches the pore space is partitioned between the gaseous and aqueous phases. Thus, the groundwater presents a radon signature from the rock that is characteristic of the aquifer. The characteristic radon concentration of an aquifer, which is mainly related to the emanation, is also influenced by the degree of subsurface degassing, especially in the vicinity of a tube well, where the radon concentration is strongly reduced. Looking for the required pumping time to take a tube well water sample that presents the characteristic radon concentration of the aquifer, an experiment was conducted in an 80 m deep tube well. In this experiment, after twenty-four hours without extraction, water samples were collected periodically, about ten minutes intervals, during two hours of pumping time. The radon concentrations of the samples were determined by using the RAD7 Electronic Radon Detector from Durridge Company, a solid state alpha spectrometric detector. It was realized that the necessary time to reach the maximum radon concentration, that means the characteristic radon concentration of the aquifer, is about sixty minutes. (author)

  17. Sampling for stereology in lungs

    Directory of Open Access Journals (Sweden)

    J. R. Nyengaard

    2006-12-01

    Full Text Available The present article reviews the relevant stereological estimators for obtaining reliable quantitative structural data from the lungs. Stereological sampling achieves reliable, quantitative information either about the whole lung or complete lobes, whilst minimising the workload. Studies have used systematic random sampling, which has fixed and constant sampling probabilities on all blocks, sections and fields of view. For an estimation of total lung or lobe volume, the Cavalieri principle can be used, but it is not useful in estimating individual cell volume due to various effects from over- or underprojection. If the number of certain structures is required, two methods can be used: the disector and the fractionator. The disector method is a three-dimensional stereological probe for sampling objects according to their number. However, it may be affected on tissue deformation and, therefore, the fractionator method is often the preferred sampling principle. In this method, a known and predetermined fraction of an object is sampled in one or more steps, with the final step estimating the number. Both methods can be performed in a physical and optical manner, therefore enabling cells and larger lung structure numbers (e.g. number of alveoli to be estimated. Some estimators also require randomisation of orientation, so that all directions have an equal chance of being chosen. Using such isotropic sections, surface area, length, and diameter can be estimated on a Cavalieri set of sections. Stereology can also illustrate the potential for transport between two compartments by analysing the barrier width. Estimating the individual volume of cells can be achieved by local stereology using a two-step procedure that first samples lung cells using the disector and then introduces individual volume estimation of the sampled cells. The coefficient of error of most unbiased stereological estimators is a combination of variance from blocks, sections, fields

  18. Water contents of samples from the Nevada Test Site: total, free (natural state to 1050C), and more tightly bonded (105 to 7000C)

    International Nuclear Information System (INIS)

    Pawloski, G.A.

    1981-05-01

    To help confirm correct functioning of an epithermal neutron sonde, we measured tightly bonded water content of selected Nevada Test Site (NTS) drill holes. Tuff and alluvium samples were dried overnight at 105 0 C. The samples were then heated for 45 min in a split tube furnace at 700 0 C. The water that came off due to this heating was collected and the amount recorded. The error in this procedure is +- 0.59 wt %. Total water can be calculated for samples from analyses of free and tightly bonded water contents. The maximum error in this calculation is equivalent to the error in determining the more tightly bonded water. Average total water content values have been assigned to geologic units. These values, in weight fraction, are alluvium 0.14 +- .05 and tuff 0.19 +- .04. Further division of the tuff gives values of Rainier Mesa 0.15 +- .01, Paintbrush 0.18 +- .03, Tunnel Beds 0.20 +- .04, and Grouse Canyon 0.29 +- .02. Statistically significant differences occur between the tuff and alluvium. Within the tuffs, these differences also occur between Grouse Canyon, Rainier Mesa, and Paintbrush/Tunnel Beds. Paintbrush and Tunnel Beds cannot be distinguished by this method

  19. Code development for eigenvalue total sensitivity analysis and total uncertainty analysis

    International Nuclear Information System (INIS)

    Wan, Chenghui; Cao, Liangzhi; Wu, Hongchun; Zu, Tiejun; Shen, Wei

    2015-01-01

    Highlights: • We develop a new code for total sensitivity and uncertainty analysis. • The implicit effects of cross sections can be considered. • The results of our code agree well with TSUNAMI-1D. • Detailed analysis for origins of implicit effects is performed. - Abstract: The uncertainties of multigroup cross sections notably impact eigenvalue of neutron-transport equation. We report on a total sensitivity analysis and total uncertainty analysis code named UNICORN that has been developed by applying the direct numerical perturbation method and statistical sampling method. In order to consider the contributions of various basic cross sections and the implicit effects which are indirect results of multigroup cross sections through resonance self-shielding calculation, an improved multigroup cross-section perturbation model is developed. The DRAGON 4.0 code, with application of WIMSD-4 format library, is used by UNICORN to carry out the resonance self-shielding and neutron-transport calculations. In addition, the bootstrap technique has been applied to the statistical sampling method in UNICORN to obtain much steadier and more reliable uncertainty results. The UNICORN code has been verified against TSUNAMI-1D by analyzing the case of TMI-1 pin-cell. The numerical results show that the total uncertainty of eigenvalue caused by cross sections can reach up to be about 0.72%. Therefore the contributions of the basic cross sections and their implicit effects are not negligible

  20. 45-Day safety screen results for Tank 241-C-101, auger sample 95-AUG-019

    International Nuclear Information System (INIS)

    Sasaki, L.M.

    1995-01-01

    One auger sample from Tank 241-C-101 was received by the 222-S Laboratory and underwent safety screening analyses--differential scanning calorimetry (DSC), thermogravimetric analysis (TGA), and total alpha analysis--in accordance with the tank characterization plan. Analytical results for the TGA on the crust sample (the uppermost portion of the auger sample) (sample number S95T000823) were less than the safety screening notification limit of 17 weight percent water. Verbal and written notifications were made on May 3, 1995. No exotherms were observed in the DSC analyses and the total alpha results were well below the safety screening notification limit. This report includes the primary safety screening results obtained from the analyses and copies of all DSC and TGA raw data scans as requested per the TCP. Although not included in this report, a photograph of the extruded sample was taken and is available. This report also includes bulk density measurements required by Characterization Plant Engineering. Additional analyses (pH, total organic carbon, and total inorganic carbon) are being performed on the drainable liquid at the request of Characterization Process Control; these analyses will be reported at a later date in a final report for this auger sample. Tank C-101 is not part of any of the four Watch Lists

  1. Efficient isotope ratio analysis of uranium particles in swipe samples by total-reflection x-ray fluorescence spectrometry and secondary ion mass spectrometry

    International Nuclear Information System (INIS)

    Esaka, Fumitaka; Watanabe, Kazuo; Fukuyama, Hiroyasu; Onodera, Takashi; Esaka, Konomi T.; Magara, Masaaki; Sakurai, Satoshi; Usuda, Shigekazu

    2004-01-01

    A new particle recovery method and a sensitive screening method were developed for subsequent isotope ratio analysis of uranium particles in safeguards swipe samples. The particles in the swipe sample were recovered onto a carrier by means of vacuum suction-impact collection method. When grease coating was applied to the carrier, the recovery efficiency was improved to 48±9%, which is superior to that of conventionally-used ultrasoneration method. Prior to isotope ratio analysis with secondary ion mass spectrometry (SIMS), total reflection X-ray fluorescence spectrometry (TXRF) was applied to screen the sample for the presence of uranium particles. By the use of Si carriers in TXRF analysis, the detection limit of 22 pg was achieved for uranium. By combining these methods with SIMS, the isotope ratios of 235 U/ 238 U for individual uranium particles were efficiently determined. (author)

  2. Quantifying regional cerebral blood flow with N-isopropyl-p-[123I]iodoamphetamine and SPECT by one-point sampling method

    International Nuclear Information System (INIS)

    Odano, Ikuo; Takahashi, Naoya; Noguchi, Eikichi; Ohtaki, Hiro; Hatano, Masayoshi; Yamazaki, Yoshihiro; Higuchi, Takeshi; Ohkubo, Masaki.

    1994-01-01

    We developed a new non-invasive technique; one-point sampling method, for quantitative measurement of regional cerebral blood flow (rCBF) with N-isopropyl-p-[ 123 I]iodoamphetamine and SPECT. Although the continuous withdrawal of arterial blood and octanol treatment of the blood are required in the conventional microsphere method, the new technique dose not require these two procedures. The total activity of 123 I-IMP obtained by the continuous withdrawal of arterial blood is inferred by the activity of 133 I-IMP obtained by the one point arterial sample using a regression line. To determine when one point sampling time was optimum for inferring integral input function of the continuous withdrawal and whether the treatment of sampled blood for octanol fraction was required, we examined a correlation between the total activity of arterial blood withdrawn from 0 to 5 min after the injection and the activity of one point sample obtained at time t, and calculated a regression line. As a result, the minimum % error for the inference using the regression line was obtained at 6 min after the 123 I-IMP injection, moreover, the octanol treatment was not required. Then examining an effect on the values of rCBF when the sampling time was deviated from 6 min, we could correct the values in approximately 3% error when the sample was obtained at 6±1 min after the injection. The one-point sampling method provides accurate and relatively non-invasive measurement of rCBF without octanol extraction of arterial blood. (author)

  3. Total alpha and beta determination by liquid scintillation counting in water samples from a Brazilian intercomparison exercise

    International Nuclear Information System (INIS)

    Dias, Fabiana F.; Taddei, Maria Helena T.; Pontedeiro, Elizabeth May Braga Dulley

    2009-01-01

    This paper describes CNEN/LAPOC's participation in the Brazilian Intercomparison Exercise (PNI) for simultaneous determination of total radioactivity in water samples, which took place in August and December 2008. The Proficiency Test (PT) also involved a short description of the nuclear analytical technique employed, emphasizing sources of uncertainty. A Liquid Scintillation System (Packard TRICARB 2700) was used with appropriate corrections applied to final results, expressed as Bq L -1 . Participation and PT data provide independent information on performance of a Laboratory and have an important role in method validation; especially because it allows the assessment of method performance over an entire range of concentrations and matrices. PT is also an important tool to demonstrate equivalence of measurements, if not their metrological comparability, and to promote education and improvement of Lab practices. (author)

  4. Determining the sample size required to establish whether a medical device is non-inferior to an external benchmark.

    Science.gov (United States)

    Sayers, Adrian; Crowther, Michael J; Judge, Andrew; Whitehouse, Michael R; Blom, Ashley W

    2017-08-28

    The use of benchmarks to assess the performance of implants such as those used in arthroplasty surgery is a widespread practice. It provides surgeons, patients and regulatory authorities with the reassurance that implants used are safe and effective. However, it is not currently clear how or how many implants should be statistically compared with a benchmark to assess whether or not that implant is superior, equivalent, non-inferior or inferior to the performance benchmark of interest.We aim to describe the methods and sample size required to conduct a one-sample non-inferiority study of a medical device for the purposes of benchmarking. Simulation study. Simulation study of a national register of medical devices. We simulated data, with and without a non-informative competing risk, to represent an arthroplasty population and describe three methods of analysis (z-test, 1-Kaplan-Meier and competing risks) commonly used in surgical research. We evaluate the performance of each method using power, bias, root-mean-square error, coverage and CI width. 1-Kaplan-Meier provides an unbiased estimate of implant net failure, which can be used to assess if a surgical device is non-inferior to an external benchmark. Small non-inferiority margins require significantly more individuals to be at risk compared with current benchmarking standards. A non-inferiority testing paradigm provides a useful framework for determining if an implant meets the required performance defined by an external benchmark. Current contemporary benchmarking standards have limited power to detect non-inferiority, and substantially larger samples sizes, in excess of 3200 procedures, are required to achieve a power greater than 60%. It is clear when benchmarking implant performance, net failure estimated using 1-KM is preferential to crude failure estimated by competing risk models. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No

  5. Fluorogenic membrane overlays to enumerate total coliforms, Escherichia coli, and total Vibrionaceae in shellfish and seawater

    Science.gov (United States)

    Three assays were developed to enumerate total coliforms, Escherichia coli, and total Vibrionaceae in shellfish and other foods and in seawater and other environmental samples. Assays involve membrane overlays of overnight colonies on non-selective agar plates to detect ß-glucuronidase and lysyl am...

  6. Multilevel systematic sampling to estimate total fruit number for yield forecasts

    DEFF Research Database (Denmark)

    Wulfsohn, Dvora-Laio; Zamora, Felipe Aravena; Tellez, Camilla Potin

    2012-01-01

    procedure for unbiased estimation of fruit number for yield forecasts. In the Spring of 2009 we estimated the total number of fruit in several rows of each of 14 commercial fruit orchards growing apple (11 groves), kiwifruit (two groves), and table grapes (one grove) in central Chile. Survey times were 10...

  7. Acceptance sampling using judgmental and randomly selected samples

    Energy Technology Data Exchange (ETDEWEB)

    Sego, Landon H.; Shulman, Stanley A.; Anderson, Kevin K.; Wilson, John E.; Pulsipher, Brent A.; Sieber, W. Karl

    2010-09-01

    We present a Bayesian model for acceptance sampling where the population consists of two groups, each with different levels of risk of containing unacceptable items. Expert opinion, or judgment, may be required to distinguish between the high and low-risk groups. Hence, high-risk items are likely to be identifed (and sampled) using expert judgment, while the remaining low-risk items are sampled randomly. We focus on the situation where all observed samples must be acceptable. Consequently, the objective of the statistical inference is to quantify the probability that a large percentage of the unsampled items in the population are also acceptable. We demonstrate that traditional (frequentist) acceptance sampling and simpler Bayesian formulations of the problem are essentially special cases of the proposed model. We explore the properties of the model in detail, and discuss the conditions necessary to ensure that required samples sizes are non-decreasing function of the population size. The method is applicable to a variety of acceptance sampling problems, and, in particular, to environmental sampling where the objective is to demonstrate the safety of reoccupying a remediated facility that has been contaminated with a lethal agent.

  8. Incidence of Mycotoxins in Local and Branded Samples of Chocolates Marketed in Pakistan

    Directory of Open Access Journals (Sweden)

    Narjis Naz

    2017-01-01

    Full Text Available The present overview was intended to evaluate the degree of total aflatoxins and ochratoxin A contamination in different samples of bitter, dark, milk, and white chocolates marketed in Pakistan. For that exploration, two hundred (n=200 samples of chocolates, 100 branded and 100 local, were analyzed for mycotoxins profile by HPLC-FLD. The outcomes firmly sustained that the majority of the samples were contaminated with aflatoxins and ochratoxin A. The incidence of total aflatoxins and ochratoxin A in branded samples was 83% and 90%, whereas the local samples showed 91% and 97% contamination, respectively. The highest amount of total aflatoxins was found in branded dark chocolates, that is, 2.27 μg/kg, and maximum ochratoxin A level was detected white chocolates (2.06 μg/kg. On average, the local white chocolates and dark chocolates faced the highest level of total aflatoxins (3.35 μg/kg and ochratoxin A (3.48 μg/kg, respectively. The local samples of chocolates were more contaminated with mycotoxins as compared to branded ones accredited to the lack of quality control and quality assurance during the manufacturing as well as packing processes. In recent years, consumption of chocolate is rapidly increasing especially by young generation, so monitoring of mycotoxin occurrence in them is a matter of great concern and more studies are required to comprehend the production of mycotoxins in these products.

  9. The use of importance sampling in a trial assessment to obtain converged estimates of radiological risk

    International Nuclear Information System (INIS)

    Johnson, K.; Lucas, R.

    1986-12-01

    In developing a methodology for assessing potential sites for the disposal of radioactive wastes, the Department of the Environment has conducted a series of trial assessment exercises. In order to produce converged estimates of radiological risk using the SYVAC A/C simulation system an efficient sampling procedure is required. Previous work has demonstrated that importance sampling can substantially increase sampling efficiency. This study used importance sampling to produce converged estimates of risk for the first DoE trial assessment. Four major nuclide chains were analysed. In each case importance sampling produced converged risk estimates with between 10 and 170 times fewer runs of the SYVAC A/C model. This increase in sampling efficiency can reduce the total elapsed time required to obtain a converged estimate of risk from one nuclide chain by a factor of 20. The results of this study suggests that the use of importance sampling could reduce the elapsed time required to perform a risk assessment of a potential site by a factor of ten. (author)

  10. Cultural Changes Required in the Army to Truly Achieve a Total Force

    Science.gov (United States)

    2016-02-16

    tailored to achieve anticipated objectives.”1 Honorable John M. McHugh , Secretary of the Army Army Directive 2012-08 (Army Total Force Policy...United States Soldier. 16 End Notes 1 McHugh , John M. “Army Directive 2012-08 (Army Total Force Policy).” Secretary of the Army, September 4...1 (February 2006): 40–42. McCullough, Amy. “Out of Reserve (Air Force Reserve Command)” 94, no. 12 (2011): 40. McHugh , John M. “Army Directive 2012

  11. Total and inorganic arsenic in foods of the first Hong Kong total diet study.

    Science.gov (United States)

    Chung, Stephen Wai-cheung; Lam, Chi-ho; Chan, Benny Tsz-pun

    2014-04-01

    Arsenic (As) is a metalloid that occurs in different inorganic and organic forms, which are found in the environment from both natural occurrence and anthropogenic activity. The inorganic forms of As (iAs) are more toxic as compared with the organic As, but so far most of the occurrence data in food collected in the framework of official food control are still reported as total As without differentiating the various As species. In this paper, total As and iAs contents of 600 total diet study (TDS) samples, subdivided into 15 different food groups, were quantified by high-resolution inductively coupled plasma mass spectrometry (HR-ICP/MS) and hydride generation (HG) ICP/MS respectively. The method detection limits for both total As and iAs were 3 μg As kg(-1). As the samples were prepared for TDS, food items were purchased directly from the market or prepared as for normal consumption, i.e. table ready, in the manner most representative of and consistent with cultural habits in Hong Kong as far as practicable. The highest total As and iAs content were found in 'fish, seafood and their products' and 'vegetables and their products' respectively. Besides, this paper also presents the ratios of iAs and total As content in different ready-to-eat food items. The highest ratio of iAs to total As was found in 'vegetables and their products'. It is likely that iAs in vegetables maintained its status even after cooking.

  12. Pattern analysis of total item score and item response of the Kessler Screening Scale for Psychological Distress (K6 in a nationally representative sample of US adults

    Directory of Open Access Journals (Sweden)

    Shinichiro Tomitaka

    2017-02-01

    Full Text Available Background Several recent studies have shown that total scores on depressive symptom measures in a general population approximate an exponential pattern except for the lower end of the distribution. Furthermore, we confirmed that the exponential pattern is present for the individual item responses on the Center for Epidemiologic Studies Depression Scale (CES-D. To confirm the reproducibility of such findings, we investigated the total score distribution and item responses of the Kessler Screening Scale for Psychological Distress (K6 in a nationally representative study. Methods Data were drawn from the National Survey of Midlife Development in the United States (MIDUS, which comprises four subsamples: (1 a national random digit dialing (RDD sample, (2 oversamples from five metropolitan areas, (3 siblings of individuals from the RDD sample, and (4 a national RDD sample of twin pairs. K6 items are scored using a 5-point scale: “none of the time,” “a little of the time,” “some of the time,” “most of the time,” and “all of the time.” The pattern of total score distribution and item responses were analyzed using graphical analysis and exponential regression model. Results The total score distributions of the four subsamples exhibited an exponential pattern with similar rate parameters. The item responses of the K6 approximated a linear pattern from “a little of the time” to “all of the time” on log-normal scales, while “none of the time” response was not related to this exponential pattern. Discussion The total score distribution and item responses of the K6 showed exponential patterns, consistent with other depressive symptom scales.

  13. Determination of As(III) and total inorganic As in water samples using an on-line solid phase extraction and flow injection hydride generation atomic absorption spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Sigrist, Mirna, E-mail: msigrist@fiq.unl.edu.ar [Laboratorio Central, Facultad de Ingenieria Quimica, Universidad Nacional del Litoral, Santiago del Estero 2654-Piso 6, (3000) Santa Fe (Argentina); Albertengo, Antonela; Beldomenico, Horacio [Laboratorio Central, Facultad de Ingenieria Quimica, Universidad Nacional del Litoral, Santiago del Estero 2654-Piso 6, (3000) Santa Fe (Argentina); Tudino, Mabel [Laboratorio de Analisis de Trazas, Departamento de Quimica Inorganica, Analitica y Quimica Fisica/INQUIMAE, Facultad de Ciencias Exactas y Naturales, Pabellon II, Ciudad Universitaria (1428), Buenos Aires (Argentina)

    2011-04-15

    A simple and robust on-line sequential injection system based on solid phase extraction (SPE) coupled to a flow injection hydride generation atomic absorption spectrometer (FI-HGAAS) with a heated quartz tube atomizer (QTA) was developed and optimized for the determination of As(III) in groundwater without any kind of sample pretreatment. The method was based on the selective retention of inorganic As(V) that was carried out by passing the filtered original sample through a cartridge containing a chloride-form strong anion exchanger. Thus the most toxic form, inorganic As(III), was determined fast and directly by AsH{sub 3} generation using 3.5 mol L{sup -1} HCl as carrier solution and 0.35% (m/v) NaBH{sub 4} in 0.025% NaOH as the reductant. Since the uptake of As(V) should be interfered by several anions of natural occurrence in waters, the effect of Cl{sup -}, SO{sub 4}{sup 2-}, NO{sub 3}{sup -}, HPO{sub 4}{sup 2-}, HCO{sub 3}{sup -} on retention was evaluated and discussed. The total soluble inorganic arsenic concentration was determined on aliquots of filtered samples acidified with concentrated HCl and pre-reduced with 5% KI-5% C{sub 6}H{sub 8}O{sub 6} solution. The concentration of As(V) was calculated by difference between the total soluble inorganic arsenic and As(III) concentrations. Detection limits (LODs) of 0.5 {mu}g L{sup -1} and 0.6 {mu}g L{sup -1} for As(III) and inorganic total As, respectively, were obtained for a 500 {mu}L sample volume. The obtained limits of detection allowed testing the water quality according to the national and international regulations. The analytical recovery for water samples spiked with As(III) ranged between 98% and 106%. The sampling throughput for As(III) determination was 60 samples h{sup -1}. The device for groundwater sampling was especially designed for the authors. Metallic components were avoided and the contact between the sample and the atmospheric oxygen was carried to a minimum. On-field arsenic species

  14. TCLP Preparation and Analysis of K East Basin Composite Sludge Samples

    International Nuclear Information System (INIS)

    Silvers, K.L.; Wagner, J.J.; Steele, R.T.

    2000-01-01

    Sludge samples from the Hanford K East Basin were analyzed by the Toxicity Characterization Leaching Procedure (TCLP) to assist in the appropriate Resource Conservation and Recovery Act (RCIL4) designation of this material. Sludge samples were collected by Fluor Hanford, Inc. using the consolidated sludge sampling system (system that allows collection of a single sample from multiple sample locations). These samples were shipped to the Postirradiation Testing Laboratory (PTL, 327 Building) and then transferred to the Pacific Northwest National Laboratory (PNNL) Radiochemical Processing Laboratory (RPL, 325 Building) for recovery and testing. Two sludge composites were prepared, using the consolidated sludge samples, to represent K East canister sludge (sample KC Can Comp) and K East floor sludge (sample KC Floor Comp). Each composite was extracted in duplicate and analyzed in duplicate following pre-approved(a) TCLP extraction and analyses procedures. In addition, these samples and duplicates were analyzed for total RCRA metals (via acid digestion preparation). The work was conducted in accordance with the requirements of the Hanford Analytical Quality Assurance Requirements Document (HASQARD). A PNNL Quality Assurance Program compliant with J HASQARD was implemented for this effort. The results from the TCLP analyses showed that all RCRA metal concentrations were less than the TCLP limits for both the canister and floor composite samples and their respective duplicates

  15. Sample Transport for a European Sample Curation Facility

    Science.gov (United States)

    Berthoud, L.; Vrublevskis, J. B.; Bennett, A.; Pottage, T.; Bridges, J. C.; Holt, J. M. C.; Dirri, F.; Longobardo, A.; Palomba, E.; Russell, S.; Smith, C.

    2018-04-01

    This work has looked at the recovery of Mars Sample Return capsule once it arrives on Earth. It covers possible landing sites, planetary protection requirements, and transportation from the landing site to a European Sample Curation Facility.

  16. Direct determination of trace elements in boron nitride powders by slurry sampling total reflection X-ray fluorescence spectrometry

    International Nuclear Information System (INIS)

    Amberger, Martin A.; Hoeltig, Michael; Broekaert, Jose A.C.

    2010-01-01

    The use of slurry sampling total reflection X-ray fluorescence spectrometry (SlS-TXRF) for the direct determination of Ca, Cr, Cu, Fe, Mn and Ti in four boron nitride powders has been described. Measurements of the zeta potential showed that slurries with good stabilities can be obtained by the addition of polyethylenimine (PEI) at a concentration of 0.1 wt.% and by adjusting the pH at 4. For the optimization of the concentration of boron nitride in the slurries the net line intensities and the signal to background ratios were determined for the trace elements Ca and Ti as well as for the internal standard element Ga in the case of concentrations of boron nitride ranging from 1 to 30 mg mL -1 . As a compromise with respect to high net line intensities and high signal to background ratios, concentrations of 5 mg mL -1 of boron nitride were found suitable and were used for all further measurements. The limits of detection of SlS-TXRF for the boron nitride powders were found to range from 0.062 to 1.6 μg g -1 for Cu and Ca, respectively. Herewith, they are higher than those obtained in solid sampling and slurry sampling graphite furnace atomic absorption spectrometry (SoS-GFAAS, SlS-GFAAS) as well as those of solid sampling electrothermal evaporation inductively coupled plasma optical emission spectrometry (SoS-ETV-ICP-OES). For Ca and Fe as well as for Cu and Fe, however, they were found to be lower than for GFAAS and for ICP-OES subsequent to wet chemical digestion, respectively. The universal applicability of SlS-TXRF to the analysis of samples with a wide variety of matrices could be demonstrated by the analysis of certified reference materials such as SiC, Al 2 O 3 , powdered bovine liver and borate ore with a single calibration. The correlation coefficients of the plots for the values found for Ca, Fe and Ti by SlS-TXRF in the boron nitride powders as well as in the before mentioned samples versus the reference values for the respective samples over a

  17. Direct determination of trace elements in boron nitride powders by slurry sampling total reflection X-ray fluorescence spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Amberger, Martin A.; Hoeltig, Michael [University of Hamburg, Institute for Inorganic and Applied Chemistry, Martin-Luther-King-Platz 6, D-20146 Hamburg (Germany); Broekaert, Jose A.C., E-mail: jose.broekaert@chemie.uni-hamburg.d [University of Hamburg, Institute for Inorganic and Applied Chemistry, Martin-Luther-King-Platz 6, D-20146 Hamburg (Germany)

    2010-02-15

    The use of slurry sampling total reflection X-ray fluorescence spectrometry (SlS-TXRF) for the direct determination of Ca, Cr, Cu, Fe, Mn and Ti in four boron nitride powders has been described. Measurements of the zeta potential showed that slurries with good stabilities can be obtained by the addition of polyethylenimine (PEI) at a concentration of 0.1 wt.% and by adjusting the pH at 4. For the optimization of the concentration of boron nitride in the slurries the net line intensities and the signal to background ratios were determined for the trace elements Ca and Ti as well as for the internal standard element Ga in the case of concentrations of boron nitride ranging from 1 to 30 mg mL{sup -1}. As a compromise with respect to high net line intensities and high signal to background ratios, concentrations of 5 mg mL{sup -1} of boron nitride were found suitable and were used for all further measurements. The limits of detection of SlS-TXRF for the boron nitride powders were found to range from 0.062 to 1.6 mug g{sup -1} for Cu and Ca, respectively. Herewith, they are higher than those obtained in solid sampling and slurry sampling graphite furnace atomic absorption spectrometry (SoS-GFAAS, SlS-GFAAS) as well as those of solid sampling electrothermal evaporation inductively coupled plasma optical emission spectrometry (SoS-ETV-ICP-OES). For Ca and Fe as well as for Cu and Fe, however, they were found to be lower than for GFAAS and for ICP-OES subsequent to wet chemical digestion, respectively. The universal applicability of SlS-TXRF to the analysis of samples with a wide variety of matrices could be demonstrated by the analysis of certified reference materials such as SiC, Al{sub 2}O{sub 3}, powdered bovine liver and borate ore with a single calibration. The correlation coefficients of the plots for the values found for Ca, Fe and Ti by SlS-TXRF in the boron nitride powders as well as in the before mentioned samples versus the reference values for the respective

  18. Sample size of the reference sample in a case-augmented study.

    Science.gov (United States)

    Ghosh, Palash; Dewanji, Anup

    2017-05-01

    The case-augmented study, in which a case sample is augmented with a reference (random) sample from the source population with only covariates information known, is becoming popular in different areas of applied science such as pharmacovigilance, ecology, and econometrics. In general, the case sample is available from some source (for example, hospital database, case registry, etc.); however, the reference sample is required to be drawn from the corresponding source population. The required minimum size of the reference sample is an important issue in this regard. In this work, we address the minimum sample size calculation and discuss related issues. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.

  19. Sample size requirements for separating out the effects of combination treatments: randomised controlled trials of combination therapy vs. standard treatment compared to factorial designs for patients with tuberculous meningitis.

    Science.gov (United States)

    Wolbers, Marcel; Heemskerk, Dorothee; Chau, Tran Thi Hong; Yen, Nguyen Thi Bich; Caws, Maxine; Farrar, Jeremy; Day, Jeremy

    2011-02-02

    In certain diseases clinical experts may judge that the intervention with the best prospects is the addition of two treatments to the standard of care. This can either be tested with a simple randomized trial of combination versus standard treatment or with a 2 x 2 factorial design. We compared the two approaches using the design of a new trial in tuberculous meningitis as an example. In that trial the combination of 2 drugs added to standard treatment is assumed to reduce the hazard of death by 30% and the sample size of the combination trial to achieve 80% power is 750 patients. We calculated the power of corresponding factorial designs with one- to sixteen-fold the sample size of the combination trial depending on the contribution of each individual drug to the combination treatment effect and the strength of an interaction between the two. In the absence of an interaction, an eight-fold increase in sample size for the factorial design as compared to the combination trial is required to get 80% power to jointly detect effects of both drugs if the contribution of the less potent treatment to the total effect is at least 35%. An eight-fold sample size increase also provides a power of 76% to detect a qualitative interaction at the one-sided 10% significance level if the individual effects of both drugs are equal. Factorial designs with a lower sample size have a high chance to be underpowered, to show significance of only one drug even if both are equally effective, and to miss important interactions. Pragmatic combination trials of multiple interventions versus standard therapy are valuable in diseases with a limited patient pool if all interventions test the same treatment concept, it is considered likely that either both or none of the individual interventions are effective, and only moderate drug interactions are suspected. An adequately powered 2 x 2 factorial design to detect effects of individual drugs would require at least 8-fold the sample size of the

  20. The minimum information required for a glycomics experiment (MIRAGE) project: sample preparation guidelines for reliable reporting of glycomics datasets.

    Science.gov (United States)

    Struwe, Weston B; Agravat, Sanjay; Aoki-Kinoshita, Kiyoko F; Campbell, Matthew P; Costello, Catherine E; Dell, Anne; Ten Feizi; Haslam, Stuart M; Karlsson, Niclas G; Khoo, Kay-Hooi; Kolarich, Daniel; Liu, Yan; McBride, Ryan; Novotny, Milos V; Packer, Nicolle H; Paulson, James C; Rapp, Erdmann; Ranzinger, Rene; Rudd, Pauline M; Smith, David F; Tiemeyer, Michael; Wells, Lance; York, William S; Zaia, Joseph; Kettner, Carsten

    2016-09-01

    The minimum information required for a glycomics experiment (MIRAGE) project was established in 2011 to provide guidelines to aid in data reporting from all types of experiments in glycomics research including mass spectrometry (MS), liquid chromatography, glycan arrays, data handling and sample preparation. MIRAGE is a concerted effort of the wider glycomics community that considers the adaptation of reporting guidelines as an important step towards critical evaluation and dissemination of datasets as well as broadening of experimental techniques worldwide. The MIRAGE Commission published reporting guidelines for MS data and here we outline guidelines for sample preparation. The sample preparation guidelines include all aspects of sample generation, purification and modification from biological and/or synthetic carbohydrate material. The application of MIRAGE sample preparation guidelines will lead to improved recording of experimental protocols and reporting of understandable and reproducible glycomics datasets. © The Author 2016. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  1. NIF total neutron yield diagnostic

    International Nuclear Information System (INIS)

    Cooper, Gary W.; Ruiz, Carlos L.

    2001-01-01

    We have designed a total neutron yield diagnostic for the National Ignition Facility (NIF) which is based on the activation of In and Cu samples. The particular approach that we have chosen is one in which we calibrate the entire counting system and which we call the ''F factor'' method. In this method, In and/or Cu samples are exposed to known sources of DD and DT neutrons. The activated samples are then counted with an appropriate system: a high purity Ge detector for In and a NaI coincidence system for Cu. We can then calculate a calibration factor, which relates measured activity to total neutron yield. The advantage of this approach is that specific knowledge of such quantities as cross sections and detector efficiencies is not needed. Unless the actual scattering environment of the NIF can be mocked up in the calibration experiment, the F factor will have to be modified using the results of a numerical simulation of the NIF scattering environment. In this article, the calibration factor methodology will be discussed and experimental results for the calibration factors will be presented. Total NIF neutron yields of 10 9 --10 19 can be measured with this method assuming a 50 cm stand-off distance can be employed for the lower yields

  2. Ensemble Sampling

    OpenAIRE

    Lu, Xiuyuan; Van Roy, Benjamin

    2017-01-01

    Thompson sampling has emerged as an effective heuristic for a broad range of online decision problems. In its basic form, the algorithm requires computing and sampling from a posterior distribution over models, which is tractable only for simple special cases. This paper develops ensemble sampling, which aims to approximate Thompson sampling while maintaining tractability even in the face of complex models such as neural networks. Ensemble sampling dramatically expands on the range of applica...

  3. Effect of gamma radiation on total antioxidant capacity, total lipid concentration and shelf life of finger millet flour

    International Nuclear Information System (INIS)

    Lathika; Manupriya, B.R.; Shenoy, K.B.; Patil, S.L.; Somashekarappa, H.M.

    2016-01-01

    The present study is an attempt to study the impact of gamma radiation on the shelf life, total antioxidant capacity and total lipid concentration of finger millet (Eleusine coracana L.) flour. Finger millet flour was procured from market. Flour samples of 50 g were taken in triplicates in a polyethylene pouch, air sealed and subjected to gamma irradiation doses ranging from 0.25 to 10 kGy and stored in polyethylene bags and plastic containers for a period of 1 year. Within 24 hours of irradiation, the samples were tested for moisture (2 ± 0.2%), total antioxidant capacity (0.12 ± 0.010 mg) and lipid concentration (15 ± 0.4 mg)

  4. Influence of sampling depth and post-sampling analysis time on the ...

    African Journals Online (AJOL)

    Bacteriological analysis was carried out for samples taken at water depth and at 1, 6, 12 and 24 hours post-sampling. It was observed that the total and faecal coliform bacteria were significantly higher in the 3 m water depth samples than in the surface water samples (ANOVA, F = 59.41, 26.751, 9.82 (T.C); 46.41, 26.81, ...

  5. Review of light water reactor regulatory requirements: Assessment of selected regulatory requirements that may have marginal importance to risk: Postaccident sampling system, Turbine missiles, Combustible gas control, Charcoal filters

    International Nuclear Information System (INIS)

    Scott, W.B.; Jamison, J.D.; Stoetzel, G.A.; Tabatabai, A.S.; Vo, T.V.

    1987-05-01

    In a study commissioned by the Nuclear Regulatory Commission (NRC), Pacific Northwest Laboratory (PNL) evaluated the costs and benefits of modifying regulatory requirements in the areas of the postaccident sampling system, turbine rotor design reviews and inspections, combustible gas control for inerted Boiling Water Reactor (BWR) containments, and impregnated charcoal filters in certain plant ventilation systems. The basic framework for the analyses was that presented in the Regulatory Analysis Guidelines (NUREG/BR-0058) and in the Handbook for Value-Impact Assessment (NUREG/CR-3568). The effects of selected modifications to regulations were evaluated in terms of such factors as public risk and costs to industry and NRC. The results indicate that potential modifications of the regulatory requirements in three of the four areas would have little impact on public risk. In the fourth area, impregnated charcoal filters in building ventilation systems do appear to limit risks to the public and plant staff. Revisions in the severe accident source term assumptions, however, may reduce the theoretical value of charcoal filters. The cost analysis indicated that substantial savings in operating costs may be realized by changing the interval of turbine rotor inspections. Small to moderate operating cost savings may be realized through postulated modifications to the postaccident sampling system requirements and to the requirements for combustible gas control in inerted BWR containments. Finally, the use of impregnated charcoal filters in ventilation systems appears to be the most cost-effective method of reducing radioiodine concentrations

  6. Rapid Determination of Total Thujone in Absinthe Using 1H NMR Spectroscopy

    Directory of Open Access Journals (Sweden)

    Yulia B. Monakhova

    2011-01-01

    Full Text Available 1H NMR spectroscopy is utilized to quantify total thujone (sum of α- and β-isomers in absinthe. For sample preparation, a simple dilution with buffer is required. Thujone produces a distinct peak of the CH2 group in the cyclopentanone moiety in the 2.13–2.11 ppm range. No overlap with other typical constituents such as anethole or fenchone occurs. The detection limit of 0.3 mg/L is adequate to control the EU maximum limit. The relative standard deviation was 6%, and linearity was observed from 1 to 100 mg/L. Applicability was proven by analysis of 69 authentic absinthes. The correlation between NMR and our previous method consisting of liquid-liquid extraction followed by GC/MS was significant (P<0.0001,R=0.93. The simple and cheap NMR method can be used for rapid screening of absinthes for total thujone content while chromatographic techniques are recommended for more specific (α- and β-thujone isomers analysis if required.

  7. A longitudinal study of quality of life and functional status in total hip and total knee replacement patients.

    Science.gov (United States)

    Mandzuk, Lynda L; McMillan, Diana E; Bohm, Eric R

    2015-05-01

    Primary total hip and primary total knee surgeries are commonly performed to improve patients' quality of life and functional status. This longitudinal retrospective study (N = 851) examined self-reported quality of life and functional status over the preoperative and postoperative periods: 12 months prior to surgery, one month prior to surgery and 12 months following surgery. A linear mixed effects model was used to analyze the changes in quality of life and functional status over the sampling period. Patients in the convenience sample reported improvements in quality of life and functional status utilizing the SF-12 and Oxford Hip and Oxford Knee, although differences were noted by procedure and gender. Total hip patients tended to demonstrate greater improvement than total knee patients and males reported higher levels of physical and mental quality of life as well as functional status when compared to females. Of particular note was that mental health scores were consistently lower in both total hip and total knee replacement patients across the perioperative period and up to one year postoperative. This study identifies an opportunity for health care providers to proactively address the mental health of total hip and total knee replacement patients throughout their joint replacement trajectory. Copyright © 2014 Elsevier Ltd. All rights reserved.

  8. Estimating the dim light melatonin onset of adolescents within a 6-h sampling window: the impact of sampling rate and threshold method.

    Science.gov (United States)

    Crowley, Stephanie J; Suh, Christina; Molina, Thomas A; Fogg, Louis F; Sharkey, Katherine M; Carskadon, Mary A

    2016-04-01

    Circadian rhythm sleep-wake disorders (CRSWDs) often manifest during the adolescent years. Measurement of circadian phase such as the dim light melatonin onset (DLMO) improves diagnosis and treatment of these disorders, but financial and time costs limit the use of DLMO phase assessments in clinic. The current analysis aims to inform a cost-effective and efficient protocol to measure the DLMO in older adolescents by reducing the number of samples and total sampling duration. A total of 66 healthy adolescents (26 males) aged 14.8-17.8 years participated in a study; they were required to sleep on a fixed baseline schedule for a week before which they visited the laboratory for saliva collection in dim light (<20 lux). Two partial 6-h salivary melatonin profiles were derived for each participant. Both profiles began 5 h before bedtime and ended 1 h after bedtime, but one profile was derived from samples taken every 30 min (13 samples) and the other from samples taken every 60 min (seven samples). Three standard thresholds (first three melatonin values mean + 2 SDs, 3 pg/mL, and 4 pg/mL) were used to compute the DLMO. An agreement between DLMOs derived from 30-min and 60-min sampling rates was determined using Bland-Altman analysis; agreement between the sampling rate DLMOs was defined as ± 1 h. Within a 6-h sampling window, 60-min sampling provided DLMO estimates within ± 1 h of DLMO from 30-min sampling, but only when an absolute threshold (3 or 4 pg/mL) was used to compute the DLMO. Future analyses should be extended to include adolescents with CRSWDs. Copyright © 2016 Elsevier B.V. All rights reserved.

  9. Determination of total alpha and beta activities on vegetable samples by LSC

    International Nuclear Information System (INIS)

    Nogueira, Regina Apolinaria; Santos, Eliane Eugenia dos; Bakker, Alexandre Pereira; Vavassori, Giullia

    2011-01-01

    Gross alpha and beta analyses are screening techniques used for environmental radioactivity monitoring. The present study proposes to determine the gross alpha and beta activities in vegetable samples by using LSC - liquid scintillation spectrometry. The procedure was applied to vegetable foods. After ashing vegetable samples in a muffle furnace, 100 mg of ash were added to gel mixture of scintillation cocktails, Water - Instagel - Ultima Gold AB (6:10:4) ml, in polyethylene vial. Am-241 standard solution and a KCl (K-40) solution were used to determine the counting configuration, alpha/beta efficiencies and spillover

  10. 45 CFR 1356.84 - Sampling.

    Science.gov (United States)

    2010-10-01

    ... 45 Public Welfare 4 2010-10-01 2010-10-01 false Sampling. 1356.84 Section 1356.84 Public Welfare....84 Sampling. (a) The State agency may collect and report the information required in section 1356.83(e) of this part on a sample of the baseline population consistent with the sampling requirements...

  11. Tannin analysis of chestnut bark samples (Castanea sativa Mill.) by HPLC-DAD-MS.

    Science.gov (United States)

    Comandini, Patrizia; Lerma-García, María Jesús; Simó-Alfonso, Ernesto Francisco; Toschi, Tullia Gallina

    2014-08-15

    In the present investigation, an HPLC-DAD/ESI-MS method for the complete analysis of tannins and other phenolic compounds of different commercial chestnut bark samples was developed. A total of seven compounds (vescalin, castalin, gallic acid, vescalagin, 1-O-galloyl castalagin, castalagin and ellagic acid) were separated and quantified, being 1-O-galloyl castalagin tentatively identified and found for the first time in chestnut bark samples. Thus, this method provided information regarding the composition and quality of chestnut bark samples, which is required since these samples are commercialised due to their biochemical properties as ingredients of food supplements. Copyright © 2014 Elsevier Ltd. All rights reserved.

  12. Total cysteine and glutathione determination in hemolymph of individual adult D. melanogaster

    Energy Technology Data Exchange (ETDEWEB)

    Borra, Srivani, E-mail: sborra3@uic.edu [Department of Chemistry, University of Illinois at Chicago, 845 West Taylor Street, 4323 SES, MC 111, Chicago, IL 60607 (United States); Featherstone, David E., E-mail: def@uic.edu [Department of Biological Sciences, University of Illinois at Chicago, 840 West Taylor Street, SEL 4311, M/C 067, Chicago, IL 60607 (United States); Laboratory of Integrative Neuroscience, University of Illinois at Chicago, 840 West Taylor Street, SEL 4311, M/C 067, Chicago, IL 60607 (United States); Shippy, Scott A., E-mail: sshippy@uic.edu [Department of Chemistry, University of Illinois at Chicago, 845 West Taylor Street, 5417 SES, MC 111, Chicago, IL 60607 (United States); Laboratory of Integrative Neuroscience, University of Illinois at Chicago, 840 West Taylor Street, SEL 4311, M/C 067, Chicago, IL 60607 (United States)

    2015-01-01

    Highlights: • Method for highly volume variant, nL sample assay of biological relevant thiols. • Defined capillary lengths used to deliver nL sample and reagent volumes. • Optimized reagent concentrations, reaction times and temperatures for thiol assay. • Total cysteine and glutathione measured from hemolymph of individual fruit flies. - Abstract: Determination of thiols, glutathione (GSH) and cysteine (Cys) are important due to their roles in oxidative stress and aging. Oxidants such as soluble O{sub 2} and H{sub 2}O{sub 2} promote oxidation of thiols to disulfide (-S-S-) bonded dimers affecting quantitation accuracy. The method presented here reduces disulfide-bonded species followed by fluorescence labelling of the 29.5 (±18.2) nL hemolymph volumes of individual adult Drosophila Melanogaster. The availability of only tens of nanoliter (nL) samples that are also highly volume variant requires efficient sample handling to improve thiol measurements while minimizing sample dilution. The optimized method presented here utilizes defined lengths of capillaries to meter tris(2-carboxyethyl)phosphine reducing reagent and monobromobimane derivatizing reagent volumes enabling Cys and GSH quantitation with only 20-fold dilution. The nL assay developed here was optimized with respect to reagent concentrations, sample dilution, reaction times and temperatures. Separation and identification of the nL thiol mixtures were obtained with capillary electrophoresis-laser induced fluorescence. To demonstrate the capability of this method total Cys and total GSH were measured in the hemolymph collected from individual adult D. Melanogaster. The thiol measurements were used to compare a mutant fly strain with a non-functional cystine–glutamate transporter (xCT) to its background control. The mutant fly, genderblind (gb), carries a non-functional gene for a protein similar to mammalian xCT whose function is not fully understood. Average concentrations obtained for mutant

  13. 40 CFR 257.23 - Ground-water sampling and analysis requirements.

    Science.gov (United States)

    2010-07-01

    ...: (1) Sample collection; (2) Sample preservation and shipment; (3) Analytical procedures; (4) Chain of... theory test, then the data should be transformed or a distribution-free theory test should be used. If... chart and its associated parameter values shall be protective of human health and the environment. The...

  14. Fluorescent fingerprints of edible oils and biodiesel by means total synchronous fluorescence and Tucker3 modeling

    Science.gov (United States)

    Insausti, Matías; de Araújo Gomes, Adriano; Camiña, José Manuel; de Araújo, Mario Cesar Ugulino; Band, Beatriz Susana Fernández

    2017-03-01

    The present work proposes the use of total synchronous fluorescence spectroscopy (TSFS) as a discrimination methodology for fluorescent compounds in edible oils, which are preserved after the transesterification processes in the biodiesel production. In the same way, a similar study is presented to identify fluorophores that do not change in expired vegetal oils, to associate physicochemical parameters to fluorescent measures, as contribution to a fingerprint for increasing the chemical knowledge of these products. The fluorescent fingerprints were obtained by Tucker3 decomposition of a three-way array of the total synchronous fluorescence matrices. This chemometric method presents the ability for modeling non-bilinear data, as Total Synchronous Fluorescence Spectra data, and consists in the decomposition of the three way data arrays (samples × Δλ × λ excitation), into four new data matrices: A (scores), B (profile in Δλ mode), C (profile in spectra mode) and G (relationships between A, B and C). In this study, 50 samples of oil from soybean, corn and sunflower seeds before and after its expiration time, as well as 50 biodiesel samples obtained by transesterification of the same oils were measured by TSFS. This study represents an immediate application of chemical fingerprint for the discrimination of non-expired and expired edible oils and biodiesel. This method does not require the use of reagents or laborious procedures for the chemical characterization of samples.

  15. Recent results of synchrotron radiation induced total reflection X-ray fluorescence analysis at HASYLAB, beamline L

    Energy Technology Data Exchange (ETDEWEB)

    Streli, C. [Atominstitut, Vienna University of Technology, Stadionallee 2, A-1020 Vienna (Austria)]. E-mail: streli@ati.ac.at; Pepponi, G. [ITC-irst, Povo (Italy); Wobrauschek, P. [Atominstitut, Vienna University of Technology, Stadionallee 2, A-1020 Vienna (Austria); Jokubonis, C. [Atominstitut, Vienna University of Technology, Stadionallee 2, A-1020 Vienna (Austria); Falkenberg, G. [Hamburger Synchrotronstrahlungslabor at Deutsches Elektronen-Synchrotron DESY, Notkestr. 85, D-22603 Hamburg (Germany); Zaray, G. [Institute of Inorganic and Applied Chemistry, 3 EOTVOS Univ, Budapest (Hungary); Broekaert, J. [Institute of Anorganic and Applied Chemistry, University Hamburg, Martin-Luther-King-Platz 6, 20146 Hamburg (Germany); Fittschen, U. [Institute of Anorganic and Applied Chemistry, University Hamburg, Martin-Luther-King-Platz 6, 20146 Hamburg (Germany); Peschel, B. [Institute of Anorganic and Applied Chemistry, University Hamburg, Martin-Luther-King-Platz 6, 20146 Hamburg (Germany)

    2006-11-15

    At the Hamburger Synchrotronstrahlungslabor (HASYLAB), Beamline L, a vacuum chamber for synchrotron radiation-induced total reflection X-ray fluorescence analysis, is now available which can easily be installed using the adjustment components for microanalysis present at this beamline. The detector is now in the final version of a Vortex silicon drift detector with 50-mm{sup 2} active area from Radiant Detector Technologies. With the Ni/C multilayer monochromator set to 17 keV extrapolated detection limits of 8 fg were obtained using the 50-mm{sup 2} silicon drift detector with 1000 s live time on a sample containing 100 pg of Ni. Various applications are presented, especially of samples which are available in very small amounts: As synchrotron radiation-induced total reflection X-ray fluorescence analysis is much more sensitive than tube-excited total reflection X-ray fluorescence analysis, the sampling time of aerosol samples can be diminished, resulting in a more precise time resolution of atmospheric events. Aerosols, directly sampled on Si reflectors in an impactor were investigated. A further application was the determination of contamination elements in a slurry of high-purity Al{sub 2}O{sub 3}. No digestion is required; the sample is pipetted and dried before analysis. A comparison with laboratory total reflection X-ray fluorescence analysis showed the higher sensitivity of synchrotron radiation-induced total reflection X-ray fluorescence analysis, more contamination elements could be detected. Using the Si-111 crystal monochromator also available at beamline L, XANES measurements to determine the chemical state were performed. This is only possible with lower sensitivity as the flux transmitted by the crystal monochromator is about a factor of 100 lower than that transmitted by the multilayer monochromator. Preliminary results of X-ray absorption near-edge structure measurements for As in xylem sap from cucumber plants fed with As(III) and As(V) are

  16. Recent results of synchrotron radiation induced total reflection X-ray fluorescence analysis at HASYLAB, beamline L

    International Nuclear Information System (INIS)

    Streli, C.; Pepponi, G.; Wobrauschek, P.; Jokubonis, C.; Falkenberg, G.; Zaray, G.; Broekaert, J.; Fittschen, U.; Peschel, B.

    2006-01-01

    At the Hamburger Synchrotronstrahlungslabor (HASYLAB), Beamline L, a vacuum chamber for synchrotron radiation-induced total reflection X-ray fluorescence analysis, is now available which can easily be installed using the adjustment components for microanalysis present at this beamline. The detector is now in the final version of a Vortex silicon drift detector with 50-mm 2 active area from Radiant Detector Technologies. With the Ni/C multilayer monochromator set to 17 keV extrapolated detection limits of 8 fg were obtained using the 50-mm 2 silicon drift detector with 1000 s live time on a sample containing 100 pg of Ni. Various applications are presented, especially of samples which are available in very small amounts: As synchrotron radiation-induced total reflection X-ray fluorescence analysis is much more sensitive than tube-excited total reflection X-ray fluorescence analysis, the sampling time of aerosol samples can be diminished, resulting in a more precise time resolution of atmospheric events. Aerosols, directly sampled on Si reflectors in an impactor were investigated. A further application was the determination of contamination elements in a slurry of high-purity Al 2 O 3 . No digestion is required; the sample is pipetted and dried before analysis. A comparison with laboratory total reflection X-ray fluorescence analysis showed the higher sensitivity of synchrotron radiation-induced total reflection X-ray fluorescence analysis, more contamination elements could be detected. Using the Si-111 crystal monochromator also available at beamline L, XANES measurements to determine the chemical state were performed. This is only possible with lower sensitivity as the flux transmitted by the crystal monochromator is about a factor of 100 lower than that transmitted by the multilayer monochromator. Preliminary results of X-ray absorption near-edge structure measurements for As in xylem sap from cucumber plants fed with As(III) and As(V) are reported. Detection

  17. Rapid Determination of Total Thujone in Absinthe Using 1H NMR Spectroscopy

    OpenAIRE

    Yulia B. Monakhova; Thomas Kuballa; Dirk W. Lachenmeier

    2011-01-01

    1H NMR spectroscopy is utilized to quantify total thujone (sum of alpha- and beta-isomers) in absinthe. For sample preparation, a simple dilution with buffer is required. Thujone produces a distinct peak of the CH2 group in the cyclopentanone moiety in the 2.13–2.11 ppm range. No overlap with other typical constituents such as anethole or fenchone occurs. The detection limit of 0.3 mg/L is adequate to control the EU maximum limit. The relative standard deviation was 6%, and linearity was obse...

  18. Total phenolics and total flavonoids in selected Indian medicinal plants.

    Science.gov (United States)

    Sulaiman, C T; Balachandran, Indira

    2012-05-01

    Plant phenolics and flavonoids have a powerful biological activity, which outlines the necessity of their determination. The phenolics and flavonoids content of 20 medicinal plants were determined in the present investigation. The phenolic content was determined by using Folin-Ciocalteu assay. The total flavonoids were measured spectrophotometrically by using the aluminium chloride colorimetric assay. The results showed that the family Mimosaceae is the richest source of phenolics, (Acacia nilotica: 80.63 mg gallic acid equivalents, Acacia catechu 78.12 mg gallic acid equivalents, Albizia lebbeck 66.23 mg gallic acid equivalents). The highest total flavonoid content was revealed in Senna tora which belongs to the family Caesalpiniaceae. The present study also shows the ratio of flavonoids to the phenolics in each sample for their specificity.

  19. Optimizing total reflection X-ray fluorescence for direct trace element quantification in proteins I: Influence of sample homogeneity and reflector type

    Science.gov (United States)

    Wellenreuther, G.; Fittschen, U. E. A.; Achard, M. E. S.; Faust, A.; Kreplin, X.; Meyer-Klaucke, W.

    2008-12-01

    Total reflection X-ray fluorescence (TXRF) is a very promising method for the direct, quick and reliable multi-elemental quantification of trace elements in protein samples. With the introduction of an internal standard consisting of two reference elements, scandium and gallium, a wide range of proteins can be analyzed, regardless of their salt content, buffer composition, additives and amino acid composition. This strategy also enables quantification of matrix effects. Two potential issues associated with drying have been considered in this study: (1) Formation of heterogeneous residues of varying thickness and/or density; and (2) separation of the internal standard and protein during drying (which has to be prevented to allow accurate quantification). These issues were investigated by microbeam X-ray fluorescence (μXRF) with special emphasis on (I) the influence of sample support and (II) the protein / buffer system used. In the first part, a model protein was studied on well established sample supports used in TXRF, PIXE and XRF (Mylar, siliconized quartz, Plexiglas and silicon). In the second part we imaged proteins of different molecular weight, oligomerization state, bound metals and solubility. A partial separation of protein and internal standard was only observed with untreated silicon, suggesting it may not be an adequate support material. Siliconized quartz proved to be the least prone to heterogeneous drying of the sample and yielded the most reliable results.

  20. Optimizing total reflection X-ray fluorescence for direct trace element quantification in proteins I: Influence of sample homogeneity and reflector type

    Energy Technology Data Exchange (ETDEWEB)

    Wellenreuther, G. [European Molecular Biology Laboratory, Notkestr. 85, 22603 Hamburg (Germany); Fittschen, U.E.A. [Department of Chemistry, University of Hamburg, Martin-Luther-King-Platz 6, 20146 Hamburg (Germany); Achard, M.E.S.; Faust, A.; Kreplin, X. [European Molecular Biology Laboratory, Notkestr. 85, 22603 Hamburg (Germany); Meyer-Klaucke, W. [European Molecular Biology Laboratory, Notkestr. 85, 22603 Hamburg (Germany)], E-mail: Wolfram@embl-hamburg.de

    2008-12-15

    Total reflection X-ray fluorescence (TXRF) is a very promising method for the direct, quick and reliable multi-elemental quantification of trace elements in protein samples. With the introduction of an internal standard consisting of two reference elements, scandium and gallium, a wide range of proteins can be analyzed, regardless of their salt content, buffer composition, additives and amino acid composition. This strategy also enables quantification of matrix effects. Two potential issues associated with drying have been considered in this study: (1) Formation of heterogeneous residues of varying thickness and/or density; and (2) separation of the internal standard and protein during drying (which has to be prevented to allow accurate quantification). These issues were investigated by microbeam X-ray fluorescence ({mu}XRF) with special emphasis on (I) the influence of sample support and (II) the protein / buffer system used. In the first part, a model protein was studied on well established sample supports used in TXRF, PIXE and XRF (Mylar, siliconized quartz, Plexiglas and silicon). In the second part we imaged proteins of different molecular weight, oligomerization state, bound metals and solubility. A partial separation of protein and internal standard was only observed with untreated silicon, suggesting it may not be an adequate support material. Siliconized quartz proved to be the least prone to heterogeneous drying of the sample and yielded the most reliable results.

  1. METHODS FOR DETERMINING AGITATOR MIXING REQUIREMENTS FOR A MIXING & SAMPLING FACILITY TO FEED WTP (WASTE TREATMENT PLANT)

    Energy Technology Data Exchange (ETDEWEB)

    GRIFFIN PW

    2009-08-27

    The following report is a summary of work conducted to evaluate the ability of existing correlative techniques and alternative methods to accurately estimate impeller speed and power requirements for mechanical mixers proposed for use in a mixing and sampling facility (MSF). The proposed facility would accept high level waste sludges from Hanford double-shell tanks and feed uniformly mixed high level waste to the Waste Treatment Plant. Numerous methods are evaluated and discussed, and resulting recommendations provided.

  2. A new sampling technique for surface exposure dating using a portable electric rock cutter

    Directory of Open Access Journals (Sweden)

    Yusuke Suganuma

    2012-07-01

    Full Text Available Surface exposure dating using in situ cosmogenic nuclides has contributed to our understanding of Earth-surface processes. The precision of the ages estimated by this method is affected by the sample geometry; therefore, high accuracy measurements of the thickness and shape of the rock sample (thickness and shape is crucial. However, it is sometimes diffi cult to meet these requirements by conventional sampling methods with a hammer and chisel. Here, we propose a new sampling technique using a portable electric rock cutter. This sampling technique is faster, produces more precisely shaped samples, and allows for a more precise age interpretation. A simple theoretical modeldemonstrates that the age error due to defective sample geometry increases as the total sample thickness increases, indicating the importance of precise sampling for surface exposure dating.

  3. Mix ratio measurements of pozzolanic blends by Fourier transform infrared-attenuated total reflectance method

    International Nuclear Information System (INIS)

    Rebagay, T.V.; Dodd, D.A.

    1992-07-01

    The disposal of low-level radioactive liquid wastes at the Hanford Site near Richland, Washington, involves mixing the wastes with pozzolanic grout-forming solid blends. Checking the quality of each blend component and its mix ratio will ensure processibility of the blend and the long-term performance of the resulting waste grout. In earlier work at Hanford laboratories, Fourier transform infrared-transmission method (FTIR-TR) using KBr pellet was applied successfully in the analysis of blends consisting of cement, fly ash, and clays. This method involves time-consuming sample preparation resulting in slow turnaround for repetitive sampling. Because reflection methods do not require elaborate sample preparation, they have the potential to reduce turnaround analysis time. Neat samples may be examined making these methods attractive for quality control. This study investigates the capability of Fourier transform infrared-attenuated total reflectance method (FTIR-ATR) to analyze pozzolanic blends

  4. Following changes in total number of mesophilic bacteria and torry meter readings in samples of fresh trout packaged in modified atmosphere and vacuum

    Directory of Open Access Journals (Sweden)

    Milijašević Milan

    2011-01-01

    Full Text Available Today, food must be healthy, subjected to minimal processing, and attractively packaged, as the expectations of consumers are ever higher. Consumers are highly sensitive to the use of additives in the food industry. There is a constant demand for fresh food that does not contain any unnecessarily added chemicals. In order to prevent spoilage of food items, an efficient and intelligent concept for preserving freshness has been developed - packaging in a modified atmosphere. Changes in a certain composition of the atmosphere within the packaging have resulted in a longer shelf life and a satisfactory quality of the food articles. Modified atmosphere packaging (MAP is well-known and has been applied in practice in the food processing industry for more than one century. The objective of these investigations was to determine the growth of the total number of mesophilic bacteria in the meat of trout packaged in a vacuum and a modified atmosphere and torry meter reading results due to changes in the dielectric characteristics of the skin that take place during the period of storage of the fresh fish. California trout (Oncorhynchus mykiss with an average weight of 293 g was used for the experimental part of the investigations. Four groups of fish samples were set up for the research. The first three groups of samples were packaged in a modified atmosphere with a different ratio of gases: Group I - 60%CO2+40%N2; Group II - 40%CO2+60%N2; Group III - 90%CO2+10%N2. Group IV comprised samples packaged in a vacuum. Investigations were carried out on days 0, 7, 14, and 21 of storage. The total number of mesophilic bacteria in the examined samples was determined according to the method ISO 4833. Measurements of changes in the dielectric characteristics of the fish skin were performed using a torry meter apparatus (The Torry Fish Freshness Meter. The results have shown that packaging of fresh trout in a modified atmosphere (60% CO2 + 40% N2 and 40% CO2 + 60% N2

  5. The requirement for proper storage of nuclear and related decommissioning samples to safeguard accuracy of tritium data.

    Science.gov (United States)

    Kim, Daeji; Croudace, Ian W; Warwick, Phillip E

    2012-04-30

    Large volumes of potentially tritium-contaminated waste materials are generated during nuclear decommissioning that require accurate characterisation prior to final waste sentencing. The practice of initially determining a radionuclide waste fingerprint for materials from an operational area is often used to save time and money but tritium cannot be included because of its tendency to be chemically mobile. This mobility demands a specific measurement for tritium and also poses a challenge in terms of sampling, storage and reliable analysis. This study shows that the extent of any tritium redistribution during storage will depend on its form or speciation and the physical conditions of storage. Any weakly or moderately bound tritium (e.g. adsorbed water, waters of hydration or crystallisation) may be variably lost at temperatures over the range 100-300 °C whereas for more strongly bound tritium (e.g. chemically bound or held in mineral lattices) the liberation temperature can be delayed up to 800 °C. For tritium that is weakly held the emanation behaviour at different temperatures becomes particularly important. The degree of (3)H loss and cross-contamination that can arise after sampling and before analysis can be reduced by appropriate storage. Storing samples in vapour tight containers at the point of sampling, the use of triple enclosures, segregating high activity samples and using a freezer all lead to good analytical practice. Copyright © 2012 Elsevier B.V. All rights reserved.

  6. Leadership and Total Quality Management

    Science.gov (United States)

    1992-04-15

    leadership and management skills yields increased productivity. This paper will focus on the skills required of senior level leaders (leaders at the...publication until it has been cleared by the appropriate mii..-, service or government agency. Leadership and Total Quality Management An Individual Study...llty Codes fAvti1 and/or DltISpecial Abstract AUTHOR: Harry D. Gatanas, LTC, USA TITLE: Leadership and Total Quality Management FORMAT- Individual

  7. Sampling Development

    Science.gov (United States)

    Adolph, Karen E.; Robinson, Scott R.

    2011-01-01

    Research in developmental psychology requires sampling at different time points. Accurate depictions of developmental change provide a foundation for further empirical studies and theories about developmental mechanisms. However, overreliance on widely spaced sampling intervals in cross-sectional and longitudinal designs threatens the validity of…

  8. [Sampling methods for PM2.5 from stationary sources: a review].

    Science.gov (United States)

    Jiang, Jing-Kun; Deng, Jian-Guo; Li, Zhen; Li, Xing-Hua; Duan, Lei; Hao, Ji-Ming

    2014-05-01

    The new China national ambient air quality standard has been published in 2012 and will be implemented in 2016. To meet the requirements in this new standard, monitoring and controlling PM2,,5 emission from stationary sources are very important. However, so far there is no national standard method on sampling PM2.5 from stationary sources. Different sampling methods for PM2.5 from stationary sources and relevant international standards were reviewed in this study. It includes the methods for PM2.5 sampling in flue gas and the methods for PM2.5 sampling after dilution. Both advantages and disadvantages of these sampling methods were discussed. For environmental management, the method for PM2.5 sampling in flue gas such as impactor and virtual impactor was suggested as a standard to determine filterable PM2.5. To evaluate environmental and health effects of PM2.5 from stationary sources, standard dilution method for sampling of total PM2.5 should be established.

  9. The quantitative LOD score: test statistic and sample size for exclusion and linkage of quantitative traits in human sibships.

    Science.gov (United States)

    Page, G P; Amos, C I; Boerwinkle, E

    1998-04-01

    We present a test statistic, the quantitative LOD (QLOD) score, for the testing of both linkage and exclusion of quantitative-trait loci in randomly selected human sibships. As with the traditional LOD score, the boundary values of 3, for linkage, and -2, for exclusion, can be used for the QLOD score. We investigated the sample sizes required for inferring exclusion and linkage, for various combinations of linked genetic variance, total heritability, recombination distance, and sibship size, using fixed-size sampling. The sample sizes required for both linkage and exclusion were not qualitatively different and depended on the percentage of variance being linked or excluded and on the total genetic variance. Information regarding linkage and exclusion in sibships larger than size 2 increased as approximately all possible pairs n(n-1)/2 up to sibships of size 6. Increasing the recombination (theta) distance between the marker and the trait loci reduced empirically the power for both linkage and exclusion, as a function of approximately (1-2theta)4.

  10. Role of QA in total quality management environment

    International Nuclear Information System (INIS)

    McCarthy, J.B.; Ayres, R.A.

    1992-01-01

    A successful company in today's highly competitive business environment must emphasize quality in all activities at all times. For most companies, this requires a major cultural change to establish appropriate operating attitudes and priorities. A total quality environment is required where quality becomes a way of life, and this process must be carefully managed. It will not be accomplished in a few short months with a simple management pronouncement. Instead, it evolves over a period of years through continuous incremental improvement. This evolution towards total quality requires a dramatic change in the quality assurance (QA) function of most companies. Traditionally, quality was automatically equated to QA and its attendant procedures and personnel. Now, quality is becoming a global concept, and QA can play a significant role in the process. The QA profession must, however, recognize and accept a new role as consultant, coach, and partner in today's total quality game. The days of the hard-line enforcer of procedural requirements are gone

  11. Speciation of Mn(II), Mn(VII) and total manganese in water and food samples by coprecipitation-atomic absorption spectrometry combination

    International Nuclear Information System (INIS)

    Citak, Demirhan; Tuzen, Mustafa; Soylak, Mustafa

    2010-01-01

    A speciation procedure based on the coprecipitation of manganese(II) with zirconium(IV) hydroxide has been developed for the investigation of levels of manganese species. The determination of manganese levels was performed by flame atomic absorption spectrometry (FAAS). Total manganese was determined after the reduction of Mn(VII) to Mn(II) by ascorbic acid. The analytical parameters including pH, amount of zirconium(IV), sample volume, etc., were investigated for the quantitative recoveries of manganese(II). The effects of matrix ions were also examined. The recoveries for manganese(II) were in the range of 95-98%. Preconcentration factor was calculated as 50. The detection limit for the analyte ions based on 3 sigma (n = 21) was 0.75 μg L -1 for Mn(II). The relative standard deviation was found to be lower than 7%. The validation of the presented procedure was performed by analysis of certified reference material having different matrices, NIST SRM 1515 (Apple Leaves) and NIST SRM 1568a (Rice Flour). The procedure was successfully applied to natural waters and food samples.

  12. An analytical protocol for the determination of total mercury concentrations in solid peat samples

    DEFF Research Database (Denmark)

    Roos-Barraclough, F; Givelet, N; Martinez-Cortizas, A

    2002-01-01

    Traditional peat sample preparation methods such as drying at high temperatures and milling may be unsuitable for Hg concentration determination in peats due to the possible presence of volatile Hg species, which could be lost during drying. Here, the effects of sample preparation and natural.......12 and 8.52 ng kg(-1) h(-1), respectively). Fertilising the peat slightly increased Hg loss (3.08 ng kg(-1) h(-1) in NPK-fertilised peat compared to 0.28 ng kg(-1) h(-1) in unfertilised peat, when averaged over all temperatures used). Homogenising samples by grinding in a machine also caused a loss of Hg....... A comparison of two Hg profiles from an Arctic peat core, measured in frozen samples and in air-dried samples, revealed that no Hg losses occurred upon air-drying. A comparison of Hg concentrations in several plant species that make up peat, showed that some species (Pinus mugo, Sphagnum recurvum...

  13. High priority tank sampling and analysis report

    International Nuclear Information System (INIS)

    Brown, T.M.

    1998-01-01

    or grab sampled and used. A total of condensed phase samples from 144 tanks were used. Vapor samples for 82 of the tanks were used to address questions needing vapor analysis results. Additional High Priority and other tanks used to address specific questions provided comparable information to that expected from the original plan. Simultaneously, a robust systems integrated approach for establishing near term sampling requirements has been established as part of the Tank Waste Remediation System's culture. No further sampling and analysis will be conducted for the sole purpose of addressing the 12 questions in the Implementation Plan. Characterization sampling and analysis will continue in support of other requirements and decision making as identified through application of the systems integrated approach

  14. An enhanced cerium(IV)-rhodamine 6G chemiluminescence system using guest-host interactions in a lab-on-a-chip platform for estimating the total phenolic content in food samples.

    Science.gov (United States)

    Al Haddabi, Buthaina; Al Lawati, Haider A J; Suliman, FakhrEldin O

    2016-04-01

    Two chemiluminescence-microfluidic (CL-MF) systems, e.g., Ce(IV)-rhodamine B (RB) and Ce(IV)-rhodamine 6G (R6G), for the determination of the total phenolic content in teas and some sweeteners were evaluated. The results indicated that the Ce(IV)-R6G system was more sensitive in comparison to the Ce(IV)-RB CL system. Therefore, a simple (CL-MF) method based on the CL of Ce(IV)-R6G was developed, and the sensitivity, selectivity and stability of this system were evaluated. Selected phenolic compounds (PCs), such as quercetin (QRC), catechin (CAT), rutin (RUT), gallic acid (GA), caffeic acid (CA) and syringic acid (SA), produced analytically useful chemiluminescence signals with low detection limits ranging from 0.35 nmol L(-1) for QRC to 11.31 nmol L(-1) for SA. The mixing sequence and the chip design were crucial, as the sensitivity and reproducibility could be substantially affected by these two factors. In addition, the anionic surfactant (i.e., sodium dodecyl sulfate (SDS)) can significantly enhance the CL signal intensity by as much as 300% for the QRC solution. Spectroscopic studies indicated that the enhancement was due to a strong guest-host interaction between the cationic R6G molecules and the anionic amphiphilic environment. Other parameters that could affect the CL intensities of the PCs were carefully optimized. Finally, the method was successfully applied to tea and sweetener samples. Six different tea samples exhibited total phenolic/antioxidant levels from 7.32 to 13.5 g per 100g of sample with respect to GA. Four different sweetener samples were also analyzed and exhibited total phenolic/antioxidant levels from 500.9 to 3422.9 mg kg(-1) with respect to GA. The method was selective, rapid and sensitive when used to estimate the total phenolic/antioxidant level, and the results were in good agreement with those reported for honey and tea samples. Copyright © 2015 Elsevier B.V. All rights reserved.

  15. Comparison of three persulfate digestion methods for total phosphorus analysis and estimation of suspended sediments

    International Nuclear Information System (INIS)

    Dayton, Elizabeth Ann; Whitacre, Shane; Holloman, Christopher

    2017-01-01

    As a result of impairments to fresh surface water quality due to phosphorus enrichment, substantial research effort has been put forth to quantify agricultural runoff phosphorus as related to on-field practices. While the analysis of runoff dissolved phosphorus is well prescribed and leaves little room for variability in methodology, there are several methods and variations of sample preparation reagents as well as analysis procedures for determining runoff total phosphorus. Due to the variation in methodology for determination of total phosphorus and an additional laboratory procedure required to measure suspended solids, the objectives of the current study are to i. compare the performance of three persulfate digestion methods (Acid Persulfate, USGS, and Alkaline Persulfate) for total phosphorus percent recovery across a wide range of suspended sediments (SS), and ii. evaluate the ability of using Al and/or Fe in digestion solution to predict SS as a surrogate to the traditional gravimetric method. Percent recovery of total phosphorus was determined using suspensions prepared from soils collected from 21 agricultural fields in Ohio. The Acid Persulfate method was most effective, with an average total phosphorus percent recovery of 96.6%. The second most effective method was the USGS with an average total phosphorus recovery of 76.1%. However, the Alkaline Persulfate method performed poorly with an average 24.5% total phosphorus recovery. As a result application of Alkaline Persulfate digestion to edge of field monitoring may drastically underestimated runoff total phosphorus. In addition to excellent recovery of total phosphorus, the Acid Persulfate method combined with analysis of Al and Fe by inductively coupled plasma atomic emission spectrometry provides a robust estimate of total SS. Due to the large quantity of samples that can result from water quality monitoring, an indirect measure of total SS could be very valuable when time and budget constraints limit

  16. Airway Complications of Total Artificial Heart.

    Science.gov (United States)

    Pathak, Vikas; Donovan, Colin; Malhotra, Rajiv

    2017-02-01

    The total artificial heart is the mechanical device which is used as a bridge to the heart transplant in patients with biventricular failure. Due to the mechanical nature of the device, patients receiving total artificial heart (TAH) require to be on anticoagulation therapy. Hemorrhage and coagulopathy are few of the known complications of TAH.

  17. Dispersion and sampling of adult Dermacentor andersoni in rangeland in Western North America.

    Science.gov (United States)

    Rochon, K; Scoles, G A; Lysyk, T J

    2012-03-01

    A fixed precision sampling plan was developed for off-host populations of adult Rocky Mountain wood tick, Dermacentor andersoni (Stiles) based on data collected by dragging at 13 locations in Alberta, Canada; Washington; and Oregon. In total, 222 site-date combinations were sampled. Each site-date combination was considered a sample, and each sample ranged in size from 86 to 250 10 m2 quadrats. Analysis of simulated quadrats ranging in size from 10 to 50 m2 indicated that the most precise sample unit was the 10 m2 quadrat. Samples taken when abundance mean-variance relationships were fit and used to predict sample sizes for a fixed level of precision. Sample sizes predicted using the Taylor model tended to underestimate actual sample sizes, while sample sizes estimated using the Iwao model tended to overestimate actual sample sizes. Using a negative binomial with common k provided estimates of required sample sizes closest to empirically calculated sample sizes.

  18. Remote sampling and analysis of highly radioactive samples in shielded boxes

    International Nuclear Information System (INIS)

    Kirpikov, D.A.; Miroshnichenko, I.V.; Pykhteev, O.Yu.

    2010-01-01

    The sampling procedure used for highly radioactive coolant water is associated with high risk of personnel irradiation and uncontrolled radioactive contamination. Remote sample manipulation with provision for proper radiation shielding is intended for safety enhancement of the sampling procedure. The sampling lines are located in an isolated compartment, a shielded box. Various equipment which enables remote or automatic sample manipulation is used for this purpose. The main issues of development of the shielded box equipment intended for a wider ranger of remote chemical analyses and manipulation techniques for highly radioactive water samples are considered in the paper. There were three principal directions of work: Transfer of chemical analysis performed in the laboratory inside the shielded box; Prevalence of computer-aided and remote techniques of highly radioactive sample manipulation inside the shielded box; and, Increase in control over sampling and determination of thermal-hydraulic parameters of the coolant water in the sampling lines. The developed equipment and solutions enable remote chemical analysis in the restricted volume of the shielded box by using ion-chromatographic, amperometrical, fluorimetric, flow injection, phototurbidimetric, conductometric and potentiometric methods. Extent of control performed in the shielded box is determined taking into account the requirements of the regulatory documents as well as feasibility and cost of the technical adaptation of various methods to the shielded box conditions. The work resulted in highly precise determination of more than 15 indexes of the coolant water quality performed in on-line mode in the shielded box. It averages to 80% of the total extent of control performed at the prototype reactor plants. The novel solutions for highly radioactive sample handling are implemented in the shielded box (for example, packaging, sample transportation to the laboratory, volume measurement). The shielded box is

  19. Advanced Curation: Solving Current and Future Sample Return Problems

    Science.gov (United States)

    Fries, M.; Calaway, M.; Evans, C.; McCubbin, F.

    2015-01-01

    Advanced Curation is a wide-ranging and comprehensive research and development effort at NASA Johnson Space Center that identifies and remediates sample related issues. For current collections, Advanced Curation investigates new cleaning, verification, and analytical techniques to assess their suitability for improving curation processes. Specific needs are also assessed for future sample return missions. For each need, a written plan is drawn up to achieve the requirement. The plan draws while upon current Curation practices, input from Curators, the analytical expertise of the Astromaterials Research and Exploration Science (ARES) team, and suitable standards maintained by ISO, IEST, NIST and other institutions. Additionally, new technologies are adopted on the bases of need and availability. Implementation plans are tested using customized trial programs with statistically robust courses of measurement, and are iterated if necessary until an implementable protocol is established. Upcoming and potential NASA missions such as OSIRIS-REx, the Asteroid Retrieval Mission (ARM), sample return missions in the New Frontiers program, and Mars sample return (MSR) all feature new difficulties and specialized sample handling requirements. The Mars 2020 mission in particular poses a suite of challenges since the mission will cache martian samples for possible return to Earth. In anticipation of future MSR, the following problems are among those under investigation: What is the most efficient means to achieve the less than 1.0 ng/sq cm total organic carbon (TOC) cleanliness required for all sample handling hardware? How do we maintain and verify cleanliness at this level? The Mars 2020 Organic Contamination Panel (OCP) predicts that organic carbon, if present, will be present at the "one to tens" of ppb level in martian near-surface samples. The same samples will likely contain wt% perchlorate salts, or approximately 1,000,000x as much perchlorate oxidizer as organic carbon

  20. Sample size requirements for separating out the effects of combination treatments: Randomised controlled trials of combination therapy vs. standard treatment compared to factorial designs for patients with tuberculous meningitis

    Directory of Open Access Journals (Sweden)

    Farrar Jeremy

    2011-02-01

    Full Text Available Abstract Background In certain diseases clinical experts may judge that the intervention with the best prospects is the addition of two treatments to the standard of care. This can either be tested with a simple randomized trial of combination versus standard treatment or with a 2 × 2 factorial design. Methods We compared the two approaches using the design of a new trial in tuberculous meningitis as an example. In that trial the combination of 2 drugs added to standard treatment is assumed to reduce the hazard of death by 30% and the sample size of the combination trial to achieve 80% power is 750 patients. We calculated the power of corresponding factorial designs with one- to sixteen-fold the sample size of the combination trial depending on the contribution of each individual drug to the combination treatment effect and the strength of an interaction between the two. Results In the absence of an interaction, an eight-fold increase in sample size for the factorial design as compared to the combination trial is required to get 80% power to jointly detect effects of both drugs if the contribution of the less potent treatment to the total effect is at least 35%. An eight-fold sample size increase also provides a power of 76% to detect a qualitative interaction at the one-sided 10% significance level if the individual effects of both drugs are equal. Factorial designs with a lower sample size have a high chance to be underpowered, to show significance of only one drug even if both are equally effective, and to miss important interactions. Conclusions Pragmatic combination trials of multiple interventions versus standard therapy are valuable in diseases with a limited patient pool if all interventions test the same treatment concept, it is considered likely that either both or none of the individual interventions are effective, and only moderate drug interactions are suspected. An adequately powered 2 × 2 factorial design to detect effects of

  1. Sources of trace elements in total diet. A statistical approach

    International Nuclear Information System (INIS)

    Aras, N.K.; Chatt, A.

    2004-01-01

    Sixteen total diet samples have been collected from two socioeconomic groups in Turkey by duplicate portion techniques. Samples were homogenized with titanium-blade homogenizer, freeze dried and analyzed for their minor and trace elements mostly by neutron activation analysis. Bread and flour samples were also collected from the same regions and analyzed similarly by instrumental neutron activation analysis. Concentrations of more than 25 elements in total diets, bread and flour, and fiber and phytate in total diets have been determined. Daily dietary intakes of these population groups, probable source of elements through correlation coefficients, and enrichment factor calculations have been determined. (author)

  2. Discrimination of the hard keratins animal horn and chelonian shell using attenuated total reflection-infrared spectroscopy.

    Science.gov (United States)

    Biscardi, Brianna; Welsh, Wendy; Kennedy, Anthony

    2012-05-01

    The ability to discriminate between objects manufactured from animal horn and chelonian (turtle, tortoise, or terrapin) shell is important from a cultural and archeological perspective such that it may allow conservators to determine the appropriate treatment and long-term care solution. It would also aid curators in identifying and cataloging items manufactured from these materials. Discrimination and classification is also a valuable tool for those involved in tracking the illegal trade in restricted materials of this nature. Attenuated total reflection infrared (ATR-IR) spectroscopy, using a single reflection diamond internal reflection element (IRE), coupled with discrimination analysis was used to analyze a total of thirty-nine samples (29 calibration samples, 10 validation samples). A discrimination analysis model was constructed using Mahalanobis distances to classify spectra into one of two classes. The model was then subsequently used to successfully classify all validation samples and correctly identify them as animal horn or chelonian shell based on second-derivative spectra of the amide I and II regions. This technique requires minimal to no sample preparation and may be used to nondestructively identify very small samples successfully without performing detailed secondary structural curve-fitting routines. This model should be a valuable resource to museums, conservators, and wildlife management programs for rapidly and reliably discriminating between animal horn and chelonian shell.

  3. Determination of total alpha index in samples of see water by coprecipitation method

    International Nuclear Information System (INIS)

    Suarez-Navarro, J.A.; Pujol, L.; Pozuelo, M.; Pablo, A. de

    1998-01-01

    An environmental radiological monitoring network in the Spanish sea waters was set up by CEDEX in 1993. Water radioactivity is determined quarterly in eleven sampling points along the Spanish coast. The gross alpha activity is one of the parameters to be determined. The usual method for monitoring the gross alpha activity includes sample evaporation to dryness on a disk and counting using ZnS(Ag) scintillation detector. Nevertheless, the gross alpha activity determination in saline waters, such as sea waters, is troublesome, because mass attenuation is high and a very small of water is needed (0.2 ml). The coprecipitation method allows to analyze 500 ml water samples, so the detection limit is reduced and sensitivity is improved. In this work, the coprecipitation method was used to determine the gross alpha activity in the radiological network of the Spanish coast sea waters during 1996 and 1997. Gross alpha activity was very homogenous. It averaged 0.0844±0.0086 Bq.1''1 and ranged from 0.062 to 0.102 Bq.1''1. In collaboration with CIEMAT a set of samples was analyzed, they averaged 0.0689±0.0074 Bq.1''1 and ranged from 0.056 to 0.082 Bq.1''1. (Author) 5 refs

  4. Evaluating Carbonate System Algorithms in a Nearshore System: Does Total Alkalinity Matter?

    Science.gov (United States)

    Jones, Jonathan M; Sweet, Julia; Brzezinski, Mark A; McNair, Heather M; Passow, Uta

    2016-01-01

    Ocean acidification is a threat to many marine organisms, especially those that use calcium carbonate to form their shells and skeletons. The ability to accurately measure the carbonate system is the first step in characterizing the drivers behind this threat. Due to logistical realities, regular carbonate system sampling is not possible in many nearshore ocean habitats, particularly in remote, difficult-to-access locations. The ability to autonomously measure the carbonate system in situ relieves many of the logistical challenges; however, it is not always possible to measure the two required carbonate parameters autonomously. Observed relationships between sea surface salinity and total alkalinity can frequently provide a second carbonate parameter thus allowing for the calculation of the entire carbonate system. Here, we assessed the rigor of estimating total alkalinity from salinity at a depth sampling water from a pier in southern California for several carbonate system parameters. Carbonate system parameters based on measured values were compared with those based on estimated TA values. Total alkalinity was not predictable from salinity or from a combination of salinity and temperature at this site. However, dissolved inorganic carbon and the calcium carbonate saturation state of these nearshore surface waters could both be estimated within on average 5% of measured values using measured pH and salinity-derived or regionally averaged total alkalinity. Thus we find that the autonomous measurement of pH and salinity can be used to monitor trends in coastal changes in DIC and saturation state and be a useful method for high-frequency, long-term monitoring of ocean acidification.

  5. Characteristics of Beverage Consumption Habits among a Large Sample of French Adults: Associations with Total Water and Energy Intakes

    Directory of Open Access Journals (Sweden)

    Fabien Szabo de Edelenyi

    2016-10-01

    Full Text Available Background: Adequate hydration is a key factor for correct functioning of both cognitive and physical processes. In France, public health recommendations about adequate total water intake (TWI only state that fluid intake should be sufficient, with particular attention paid to hydration for seniors, especially during heatwave periods. The objective of this study was to calculate the total amount of water coming from food and beverages and to analyse characteristics of consumption in participants from a large French national cohort. Methods: TWI, as well as contribution of food and beverages to TWI was assessed among 94,939 adult participants in the Nutrinet-Santé cohort (78% women, mean age 42.9 (SE 0.04 using three 24-h dietary records at baseline. Statistical differences in water intakes across age groups, seasons and day of the week were assessed. Results: The mean TWI was 2.3 L (Standard Error SE 4.7 for men and 2.1 L (SE 2.4 for women. A majority of the sample did comply with the European Food Safety Authority (EFSA adequate intake recommendation, especially women. Mean total energy intake (EI was 1884 kcal/day (SE 1.5 (2250 kcal/day (SE 3.6 for men and 1783 kcal/day (SE 1.5 for women. The contribution to the total EI from beverages was 8.3%. Water was the most consumed beverage, followed by hot beverages. The variety score, defined as the number of different categories of beverages consumed during the three 24-h records out of a maximum of 8, was positively correlated with TWI (r = 0.4; and with EI (r = 0.2, suggesting that beverage variety is an indicator of higher consumption of food and drinks. We found differences in beverage consumptions and water intakes according to age and seasonality. Conclusions: The present study gives an overview of the water intake characteristics in a large population of French adults. TWI was found to be globally in line with public health recommendations.

  6. Drone Transport of Chemistry and Hematology Samples Over Long Distances.

    Science.gov (United States)

    Amukele, Timothy K; Hernandez, James; Snozek, Christine L H; Wyatt, Ryan G; Douglas, Matthew; Amini, Richard; Street, Jeff

    2017-11-02

    We addressed the stability of biological samples in prolonged drone flights by obtaining paired chemistry and hematology samples from 21 adult volunteers in a single phlebotomy event-84 samples total. Half of the samples were held stationary, while the other samples were flown for 3 hours (258 km) in a custom active cooling box mounted on the drone. After the flight, 19 chemistry and hematology tests were performed. Seventeen analytes had small or no bias, but glucose and potassium in flown samples showed an 8% and 6.2% bias, respectively. The flown samples (mean, 24.8°C) were a mean of 2.5°C cooler than the stationary samples (mean, 27.3°C) during transportation to the flight field as well as during the flight. The changes in glucose and potassium are consistent with the magnitude and duration of the temperature difference between the flown and stationary samples. Long drone flights of biological samples are feasible but require stringent environmental controls to ensure consistent results. © American Society for Clinical Pathology, 2017. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com

  7. Technologies for pre-screening IAEA swipe samples

    International Nuclear Information System (INIS)

    Smith, Nicholas A.; Steeb, Jennifer L.; Lee, Denise L.; Huckabay, Heath A.; Ticknor, Brian W.

    2015-01-01

    During the course of International Atomic Energy Agency (IAEA) inspections, many samples are taken for the purpose of verifying the declared facility activities and identifying any possible undeclared activities. One of these sampling techniques is the environmental swipe sample. Due to the large number of samples collected, and the amount of time that is required to analyze them, prioritizing these swipes in the field or upon receipt at the Network of Analytical Laboratories (NWAL) will allow sensitive or mission-critical analyses to be performed sooner. As a result of this study, technologies were placed into one of three categories: recommended, promising, or not recommended. Both neutron activation analysis (NAA) and X-ray fluorescence (XRF) are recommended for further study and possible field deployment. These techniques performed the best in initial trials for pre-screening and prioritizing IAEA swipes. We learned that for NAA more characterization of cold elements (such as calcium and magnesium) would need to be emphasized, and for XRF it may be appropriate to move towards a benchtop XRF versus a handheld XRF due to the increased range of elements available on benchtop equipment. Promising techniques that will require additional research and development include confocal Raman microscopy, fluorescence microscopy, and infrared (IR) microscopy. These techniques showed substantive responses to uranium compounds, but expensive instrumentation upgrades (confocal Raman) or university engagement (fluorescence microscopy) may be necessary to investigate the utility of the techniques completely. Point-and-shoot (handheld) Raman and attenuated total reflectance–infrared (ATR-IR) measurements are not recommended, as they have not shown enough promise to continue investigations.

  8. Technologies for pre-screening IAEA swipe samples

    Energy Technology Data Exchange (ETDEWEB)

    Smith, Nicholas A. [Argonne National Lab. (ANL), Argonne, IL (United States); Steeb, Jennifer L. [Argonne National Lab. (ANL), Argonne, IL (United States); Lee, Denise L. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Huckabay, Heath A. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Ticknor, Brian W. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2015-11-09

    During the course of International Atomic Energy Agency (IAEA) inspections, many samples are taken for the purpose of verifying the declared facility activities and identifying any possible undeclared activities. One of these sampling techniques is the environmental swipe sample. Due to the large number of samples collected, and the amount of time that is required to analyze them, prioritizing these swipes in the field or upon receipt at the Network of Analytical Laboratories (NWAL) will allow sensitive or mission-critical analyses to be performed sooner. As a result of this study, technologies were placed into one of three categories: recommended, promising, or not recommended. Both neutron activation analysis (NAA) and X-ray fluorescence (XRF) are recommended for further study and possible field deployment. These techniques performed the best in initial trials for pre-screening and prioritizing IAEA swipes. We learned that for NAA more characterization of cold elements (such as calcium and magnesium) would need to be emphasized, and for XRF it may be appropriate to move towards a benchtop XRF versus a handheld XRF due to the increased range of elements available on benchtop equipment. Promising techniques that will require additional research and development include confocal Raman microscopy, fluorescence microscopy, and infrared (IR) microscopy. These techniques showed substantive responses to uranium compounds, but expensive instrumentation upgrades (confocal Raman) or university engagement (fluorescence microscopy) may be necessary to investigate the utility of the techniques completely. Point-and-shoot (handheld) Raman and attenuated total reflectance–infrared (ATR-IR) measurements are not recommended, as they have not shown enough promise to continue investigations.

  9. Technical Note: Precise quantitative measurements of total dissolved inorganic carbon from small amounts of seawater using a gas chromatographic system

    Directory of Open Access Journals (Sweden)

    T. Hansen

    2013-10-01

    Full Text Available Total dissolved inorganic carbon (CT is one of the most frequently measured parameters used to calculate the partial pressure of carbon dioxide in seawater. Its determination has become increasingly important because of the rising interest in the biological effects of ocean acidification. Coulometric and infrared detection methods are currently favored in order to precisely quantify CT. These methods however are not sufficiently validated for CT measurements of biological experiments manipulating seawater carbonate chemistry with an extended CT measurement range (~1250–2400 μmol kg–1 compared to natural open ocean seawater (~1950–2200 μmol kg−1. The requirement of total sample amounts between 0.1–1 L seawater in the coulometric- and infrared detection methods potentially exclude their use for experiments working with much smaller volumes. Additionally, precise CT analytics become difficult with high amounts of biomass (e.g., phytoplankton cultures or even impossible in the presence of planktonic calcifiers without sample pre-filtration. Filtration however, can alter CT concentration through gas exchange induced by high pressure. Addressing these problems, we present precise quantification of CT using a small, basic and inexpensive gas chromatograph as a CT analyzer. Our technique is able to provide a repeatability of ±3.1 μmol kg−1, given by the pooled standard deviation over a CT range typically applied in acidification experiments. 200 μL of sample is required to perform the actual CT measurement. The total sample amount needed is 12 mL. Moreover, we show that sample filtration is applicable with only minor alteration of the CT. The method is simple, reliable and with low cumulative material costs. Hence, it is potentially attractive for all researchers experimentally manipulating the seawater carbonate system.

  10. Creel survey sampling designs for estimating effort in short-duration Chinook salmon fisheries

    Science.gov (United States)

    McCormick, Joshua L.; Quist, Michael C.; Schill, Daniel J.

    2013-01-01

    Chinook Salmon Oncorhynchus tshawytscha sport fisheries in the Columbia River basin are commonly monitored using roving creel survey designs and require precise, unbiased catch estimates. The objective of this study was to examine the relative bias and precision of total catch estimates using various sampling designs to estimate angling effort under the assumption that mean catch rate was known. We obtained information on angling populations based on direct visual observations of portions of Chinook Salmon fisheries in three Idaho river systems over a 23-d period. Based on the angling population, Monte Carlo simulations were used to evaluate the properties of effort and catch estimates for each sampling design. All sampling designs evaluated were relatively unbiased. Systematic random sampling (SYS) resulted in the most precise estimates. The SYS and simple random sampling designs had mean square error (MSE) estimates that were generally half of those observed with cluster sampling designs. The SYS design was more efficient (i.e., higher accuracy per unit cost) than a two-cluster design. Increasing the number of clusters available for sampling within a day decreased the MSE of estimates of daily angling effort, but the MSE of total catch estimates was variable depending on the fishery. The results of our simulations provide guidelines on the relative influence of sample sizes and sampling designs on parameters of interest in short-duration Chinook Salmon fisheries.

  11. Microfabricated Devices for Sample Extraction, Concentrations, and Related Sample Processing Technologies

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Gang; Lin, Yuehe

    2006-12-01

    This is an invited book chapter. As with other analytical techniques, sample pretreatments, sample extraction, sample introduction, and related techniques are of extreme importance for micro-electro-mechanical systems (MEMS). Bio-MEMS devices and systems start with a sampling step. The biological sample then usually undergoes some kinds of sample preparation steps before the actual analysis. These steps may involve extracting the target sample from its matrix, removing interferences from the sample, derivatizing the sample to detectable species, or performing a sample preconcentration step. The integration of the components for sample pretreatment into microfluidic devices represents one of the remaining the bottle-neck towards achieving true miniaturized total analysis systems (?TAS). This chapter provides a thorough state-of-art of the developments in this field to date.

  12. Total quality management in American industry.

    Science.gov (United States)

    Widtfeldt, A K; Widtfeldt, J R

    1992-07-01

    The definition of total quality management is conformance to customer requirements and specifications, fitness for use, buyer satisfaction, and value at an affordable price. The three individuals who have developed the total quality management concepts in the United States are W.E. Deming, J.M. Juran, and Philip Crosby. The universal principles of total quality management are (a) a customer focus, (b) management commitment, (c) training, (d) process capability and control, and (e) measurement through quality improvement tools. Results from the National Demonstration Project on Quality Improvement in Health Care showed the principles of total quality management could be applied to healthcare.

  13. Neutron total cross section measurements on 249Cf

    International Nuclear Information System (INIS)

    Carlton, R.F.; Harvey, J.A.; Hill, N.W.; Pandey, M.S.; Benjamin, R.W.

    1979-01-01

    Neutron total cross section measurements were performed on a sample of 249 Cf (5.65 mg total weight) with the ORELA as a source of pulsed neutrons. The sample, the inverse thickness of which was 1542 barns/atom, consisted of 85.3% 249 Cf and 14.4% 249 Bk, and was cooled to liquid nitrogen temperature. Analyses were also made of data from a thin sample (l/n = 17430) of 65% 249 Cf in the region of the large fission resonance at 0.7 eV. Fifty-five resonances in 249 Cf were observed and analyzed over the energy range 0.1 eV to 90 eV by use of an R-matrix multilevel formalism. The resonance parameters obtained were used to determine the level spacing and the s-wave neutron and fission strength functions. Thermal total cross section measurements were also performed. 5 figures, 3 tables

  14. Quantitative determination of iron, copper, lead, chromium and nickel in electronic waste samples using total reflection x-ray fluorescence spectroscopy

    International Nuclear Information System (INIS)

    Elaseer, A. S.; Musbah, A. S; Ammar, M. M. G.; Salah, M. A.; Aisha, E. A.

    2015-01-01

    Total reflection x-ray fluorescence spectroscopy in conjunction with microwave assisted extraction technique was used for the analysis of twenty electronic waste samples. The analysis was limited to the printed circuit boards of electronic devices. Iron, copper, lead, chromium and nickel were quantitatively determined in the samples. The samples were carefully milled to fine powder and 50mg was digested by acid using microwave digestion procedure. The digested samples solution was spread together with gallium as internal standard on the reflection disk and analyzed. The results showed that the cassette recorder boards contain the highest concentration of iron, lead and nickel. The average concentrations of these metals were 78, 73 and 71g/Kg respectively. Computer boards contained the highest copper average concentration 39g/Kg. the highest chromium average concentration 3.6 g/Kg was in mobile phone boards. Measurements were made using PicoTAX portable x-ray device. the instrument was used for quantitative multi-element analysis. An air cooled x-ray tube (40KV, 1 mA) with Mo target and Be window was used as x-ray source. The optics of the device was a multilayer Ni/C, 17.5 keV, 80% reflectivity provides analysis of elements from Si to Zr (K series) and Rh to U (L series). A Si PIN-diode detector (7mm"2, 195eV) was used for the elements detection. In this study heavy metals average concentration in electronic circuit boards in the in the order of iron (35.25g/kg), copper (21.14g/Kg), lead (16.59g/Kg), nickel (16.01g/Kg) and chromium (1.07g/Kg).(author)

  15. Single tag for total carbohydrate analysis.

    Science.gov (United States)

    Anumula, Kalyan Rao

    2014-07-15

    Anthranilic acid (2-aminobenzoic acid, 2-AA) has the remarkable property of reacting rapidly with every type of reducing carbohydrate. Reactivity of 2-AA with carbohydrates in aqueous solutions surpasses all other tags reported to date. This unique capability is attributed to the strategically located -COOH which accelerates Schiff base formation. Monosaccharides, oligosaccharides (N-, O-, and lipid linked and glycans in secretory fluids), glycosaminoglycans, and polysaccharides can be easily labeled with 2-AA. With 2-AA, labeling is simple in aqueous solutions containing proteins, peptides, buffer salts, and other ingredients (e.g., PNGase F, glycosidase, and transferase reaction mixtures). In contrast, other tags require relatively pure glycans for labeling in anhydrous dimethyl sulfoxide-acetic acid medium. Acidic conditions are known to cause desialylation, thus requiring a great deal of attention to sample preparation. Simpler labeling is achieved with 2-AA within 30-60 min in mild acetate-borate buffered solution. 2-AA provides the highest sensitivity and resolution in chromatographic methods for carbohydrate analysis in a simple manner. Additionally, 2-AA is uniquely qualified for quantitative analysis by mass spectrometry in the negative mode. Analyses of 2-AA-labeled carbohydrates by electrophoresis and other techniques have been reported. Examples cited here demonstrate that 2-AA is the universal tag for total carbohydrate analysis. Copyright © 2014 Elsevier Inc. All rights reserved.

  16. Monopolist requires totally liberalization

    International Nuclear Information System (INIS)

    Janoska, J.

    2003-01-01

    Slovenske elektrarne (SE), a.s, Bratislava in present time operates some sources, which would be off at normal conditions. It was caused by high electricity price on European markets. It is possible to sell 1 MWh for 12 thousands Slovak crowns abroad in last months. It is also advantageous to initialise thermal sources for power plant, where variable expenses are higher - from 1200 to 1300 Slovak crowns per MWh. SE are mainly trying to sell most of electricity on domestic market because returnability of dominant nuclear power plants was projected for this market. Utilizing capacities profit via domestic market covers fixed costs of power plants. Besides, power plant can demand regulated price 1272 Slovak crowns per 1 MWh. SE sources have capacity of 6800 MW, but maximal daily load uses for example in December approximately 4000 MW. Overflows are more higher in the summer - load dropped to 2200 MW in the beginning of September in last year. It is noted in issue that price increase in Europe is noticed. Price of primary power electricity will remain at liquid markets at 28 Euro (1176 Slovak crowns) in the following year prices fluctuate from 38 to 40 Euro (to 1700 Slovak crowns) per 1 MW at load peaks. Price increase is caused by lack of sources - it does not keep up to satisfy demand increase. Sources are gradually laid up and no new sources are built. Production capacities will decrease also in SE - by laying up of two 440 MW blocks of Bohunice NPP V-1. Price increase trend will continue according to SE businessmen till it is advantageous to build new source. Present price trend can be accelerated by decision about completing of Mochovce NPP 3-4

  17. Bioimpedance index for measurement of total body water in severely malnourished children

    DEFF Research Database (Denmark)

    Girma, Tsinuel; Kæstel, Pernille; Workeneh, Netsanet

    2016-01-01

    BACKGROUND & OBJECTIVES: Restoration of body composition indicates successful management of severe acute malnutrition (SAM). Bioimpedance (BI) index (height(2)/resistance) is used to predict total body water (TBW) but its performance in SAM, especially with oedema, requires further investigation....... SUBJECTS/METHODS: Children with SAM (mid-arm circumference ...Hzs. Pre- and post-deuterium dose saliva samples were analysed using isotope-ratio mass spectrometry. TBW was regressed on H(2)/Z. Xc and R were height (H)-indexed, and Xc/H plotted against R/H. RESULTS: Thirty five children (16 non-oedematous and 19 oedematous) with median (interquartile range) age of 42...

  18. Sampling bee communities using pan traps: alternative methods increase sample size

    Science.gov (United States)

    Monitoring of the status of bee populations and inventories of bee faunas require systematic sampling. Efficiency and ease of implementation has encouraged the use of pan traps to sample bees. Efforts to find an optimal standardized sampling method for pan traps have focused on pan trap color. Th...

  19. Determination of dietary intake of total arsenic, inorganic arsenic and total mercury in the Chilean school meal program.

    Science.gov (United States)

    Bastías, J M; Bermúdez, M; Carrasco, J; Espinoza, O; Muñoz, M; Galotto, M J; Muñoz, O

    2010-10-01

    The dietary intake of total arsenic (tAs), inorganic arsenic (iAs) and total mercury (tHg) in lunch and breakfast servings provided by the Chilean School Meal Program (SMP) was estimated, using the duplicate-portion variant of the total diet study. Lunch and breakfast samples were collected from 65 schools throughout the country in 2006. The population sample was a group of girls and boys between 6 and 18 years old. The tAs concentration was measured via hydride-generation atomic absorption spectrometry. The total mercury concentration was measured via cold-vapor atomic absorption spectroscopy. The estimated iAs intake was 12.5% (5.4 μg/day) of the Provisional tolerable daily intake (PTDI) as proposed by the FAO/WHO, and the tHg intake was 13.2% (1.9 μg/day) of the PTDI as proposed by the FAO/WHO. It was therefore concluded that tAs, iAs and tHg intake from food provided by the SMP do not pose risks to student health.

  20. 21 CFR 203.38 - Sample lot or control numbers; labeling of sample units.

    Science.gov (United States)

    2010-04-01

    ... numbers; labeling of sample units. (a) Lot or control number required on drug sample labeling and sample... identifying lot or control number that will permit the tracking of the distribution of each drug sample unit... 21 Food and Drugs 4 2010-04-01 2010-04-01 false Sample lot or control numbers; labeling of sample...

  1. Gas generation from Hanford grout samples

    International Nuclear Information System (INIS)

    Jonah, C.D.; Kapoor, S.; Matheson, M.S.; Mulac, W.A.; Meisel, D.

    1996-01-01

    In an extension of our work on the radiolytic processes that occur in the waste tanks at the Hanford site, we studied the gas generation from grout samples that contained nuclear waste simulants. Grout is one option for the long-term storage of low-level nuclear waste solutions but the radiolytic effects on grout have not been thoroughly defined. In particular, the generation of potentially flammable and hazardous gases required quantification. A research team at Argonne examined this issue and found that the total amount of gases generated radiolytically from the WHC samples was an order of magnitude higher than predicted. This implies that novel pathways fro charge migration from the solid grout to the associated water are responsible for gas evolution. The grout samples produced hydrogen, nitrous oxide, and carbon monoxide as well as nitrogen and oxygen. Yields of each of these substances were determined for doses that are equivalent to about 80 years storage of the grout. Carbon monoxide, which was produced in 2% yield, is of particular importance because even small amounts may adversely affect catalytic conversion instrumentation that has been planned for installation in the storage vaults

  2. Screening of IAEA environmental samples for fissile material content

    International Nuclear Information System (INIS)

    Hembree, Doyle M. Jr.; Carter, Joel A.; Devault, Gerald L.; Whitaker, J. Michael; Glasgow, David

    2001-01-01

    Full text: Analysis of environmental samples for the International Atomic Energy Agency (IAEA) Strengthened Safeguards Systems program requires that stringent measures be taken to control contamination. To facilitate contamination control, it is extremely useful to have some estimate of the fissile content of a given sample prior to beginning sample preparation and analysis. This is particularly true for laboratories that employ clean rooms during sample preparation. A review of the analytical results for samples submitted between January 1, 1999 and September 1, 2000 revealed that the total uranium content values ranged from 0.2 to greater than 500,000 ng/sample. Poor estimates of the uranium or plutonium content in the samples have caused some of the laboratories in the IAEA Network of Analytical Laboratories (NWAL) to experience clean laboratory contamination, sample cross contamination, and non-ideal uranium spike additions. This has led to significant increases in analysis costs (e.g., recertification of clean rooms after removing contamination, and rerunning samples) and degradation in data quality. A number of methods have been proposed for screening environmental samples for fissile material content, including gamma spectrometry, x-ray fluorescence, kinetic phosphorimetry (KPA), and inductively coupled plasma-mass spectrometry (ICP-MS). Gamma spectrometry and x-ray fluorescence are suitable for screening samples with microgram or greater quantities of uranium. ICP-MS and KPA are used successfully in some DOE NWAL laboratories to screen environmental samples. A neutron activation analysis (NAA) method that offers numerous advantages over other screening techniques for environmental samples has recently been proposed. Fissile materials such as 239 Pu and 235 U can be made to undergo fission in the intense neutron field to which they are exposed during neutron activation analysis (NAA). Some of the fission products emit neutrons referred to as 'delayed

  3. Analysis of total and dissolved heavy metals in surface water of a Mexican polluted river by total reflection X-ray fluorescence spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Zarazua, G. [Instituto Nacional de Investigaciones Nucleares, Gerencia de Ciencias Ambientales, Apartado Postal 18-1027, Mexico D.F., C.P. 11801 (Mexico)]. E-mail: gzo@nuclear.inin.mx; Avila-Perez, P. [Instituto Nacional de Investigaciones Nucleares, Gerencia de Ciencias Ambientales, Apartado Postal 18-1027, Mexico D.F., C.P. 11801 (Mexico); Tejeda, S. [Instituto Nacional de Investigaciones Nucleares, Gerencia de Ciencias Ambientales, Apartado Postal 18-1027, Mexico D.F., C.P. 11801 (Mexico); Barcelo-Quintal, I. [Universidad Autonoma Metropolitana, Unidad Azcapotzalco, Mexico, D.F. (Mexico); Martinez, T. [Universidad Nacional Autonoma de Mexico, Facultad de Quimica, Mexico, D.F. (Mexico)

    2006-11-15

    The present area of study is located in the Upper Course of the Lerma River (UCLR). The Lerma is one of the most important rivers of Mexico, where it drains highly populated and industrialized regions. The aim of the present study is to determine the heavy metal concentration of Cr, Mn, Fe, Cu and Pb in dissolved and total phases of the UCLR by means of Total Reflection X-ray Fluorescence Spectrometry (TXRF). The surface water samples were collected at 8 sites distributed following the stream flow direction of the river. Four sampling campaigns were carried out in each site in a 1-year period. A sample preparation method was applied in order to obtain the total and dissolved fraction and to destroy the organic matter. The total heavy metal average concentration decrease in the following order: Fe (2566 {mu}g/L) > Mn (300 {mu}g/L) > Cu (66 {mu}g/L) > Cr (21 {mu}g/L) > Pb (15 {mu}g/L). In general, the heavy metal concentrations in water of the UCLR are below the maximum permissible limits.

  4. Analysis of total and dissolved heavy metals in surface water of a Mexican polluted river by total reflection X-ray fluorescence spectrometry

    Science.gov (United States)

    Zarazua, G.; Ávila-Pérez, P.; Tejeda, S.; Barcelo-Quintal, I.; Martínez, T.

    2006-11-01

    The present area of study is located in the Upper Course of the Lerma River (UCLR). The Lerma is one of the most important rivers of Mexico, where it drains highly populated and industrialized regions. The aim of the present study is to determine the heavy metal concentration of Cr, Mn, Fe, Cu and Pb in dissolved and total phases of the UCLR by means of Total Reflection X-ray Fluorescence Spectrometry (TXRF). The surface water samples were collected at 8 sites distributed following the stream flow direction of the river. Four sampling campaigns were carried out in each site in a 1-year period. A sample preparation method was applied in order to obtain the total and dissolved fraction and to destroy the organic matter. The total heavy metal average concentration decrease in the following order: Fe (2566 μg/L) > Mn (300 μg/L) > Cu (66 μg/L) > Cr (21 μg/L) > Pb (15 μg/L). In general, the heavy metal concentrations in water of the UCLR are below the maximum permissible limits.

  5. Analysis of total and dissolved heavy metals in surface water of a Mexican polluted river by total reflection X-ray fluorescence spectrometry

    International Nuclear Information System (INIS)

    Zarazua, G.; Avila-Perez, P.; Tejeda, S.; Barcelo-Quintal, I.; Martinez, T.

    2006-01-01

    The present area of study is located in the Upper Course of the Lerma River (UCLR). The Lerma is one of the most important rivers of Mexico, where it drains highly populated and industrialized regions. The aim of the present study is to determine the heavy metal concentration of Cr, Mn, Fe, Cu and Pb in dissolved and total phases of the UCLR by means of Total Reflection X-ray Fluorescence Spectrometry (TXRF). The surface water samples were collected at 8 sites distributed following the stream flow direction of the river. Four sampling campaigns were carried out in each site in a 1-year period. A sample preparation method was applied in order to obtain the total and dissolved fraction and to destroy the organic matter. The total heavy metal average concentration decrease in the following order: Fe (2566 μg/L) > Mn (300 μg/L) > Cu (66 μg/L) > Cr (21 μg/L) > Pb (15 μg/L). In general, the heavy metal concentrations in water of the UCLR are below the maximum permissible limits

  6. Validation of a radioimmunoassay for the determination of total corticosterone in rat plasma

    DEFF Research Database (Denmark)

    Pedersen, Tine Karen Hjort

    2000-01-01

    Abstract A radioimmunoassay (RIA) for total corticosterone (CORT) in rat plasma requiring a plasma volume of 2 μl was established. The importance of inactivating plasma corticosteroid-binding globulin (CBG), denatured by heat, before measuring CORT was shown. The method was evaluated and shown...... the blood sampling procedure. The result showed that the method had a capacity to detect CORT concentrations comparable with previous reported basal concentrations. Finally, the possible stress inducing effect of the blood sampling procedure was examined using two groups of male rats housed under either...... conventional or enriched environmental conditions. The result indicated that conventional environment housing induces slightly stressed animals compared to enriched housing. Enriched housing may provide an environment that makes it possible for rats to compensate for a stressful situation, i.e., the blood...

  7. Optimal sampling plan for clean development mechanism lighting projects with lamp population decay

    International Nuclear Information System (INIS)

    Ye, Xianming; Xia, Xiaohua; Zhang, Jiangfeng

    2014-01-01

    Highlights: • A metering cost minimisation model is built with the lamp population decay to optimise CDM lighting projects sampling plan. • The model minimises the total metering cost and optimise the annual sample size during the crediting period. • The required 90/10 criterion sampling accuracy is satisfied for each CDM monitoring report. - Abstract: This paper proposes a metering cost minimisation model that minimises metering cost under the constraints of sampling accuracy requirement for clean development mechanism (CDM) energy efficiency (EE) lighting project. Usually small scale (SSC) CDM EE lighting projects expect a crediting period of 10 years given that the lighting population will decay as time goes by. The SSC CDM sampling guideline requires that the monitored key parameters for the carbon emission reduction quantification must satisfy the sampling accuracy of 90% confidence and 10% precision, known as the 90/10 criterion. For the existing registered CDM lighting projects, sample sizes are either decided by professional judgment or by rule-of-thumb without considering any optimisation. Lighting samples are randomly selected and their energy consumptions are monitored continuously by power meters. In this study, the sampling size determination problem is formulated as a metering cost minimisation model by incorporating a linear lighting decay model as given by the CDM guideline AMS-II.J. The 90/10 criterion is formulated as constraints to the metering cost minimisation problem. Optimal solutions to the problem minimise the metering cost whilst satisfying the 90/10 criterion for each reporting period. The proposed metering cost minimisation model is applicable to other CDM lighting projects with different population decay characteristics as well

  8. Systematic sampling for suspended sediment

    Science.gov (United States)

    Robert B. Thomas

    1991-01-01

    Abstract - Because of high costs or complex logistics, scientific populations cannot be measured entirely and must be sampled. Accepted scientific practice holds that sample selection be based on statistical principles to assure objectivity when estimating totals and variances. Probability sampling--obtaining samples with known probabilities--is the only method that...

  9. Sampling and sample handling procedures for priority pollutants in surface coal mining wastewaters. [Detailed list to be analyzed for

    Energy Technology Data Exchange (ETDEWEB)

    Hayden, R. S.; Johnson, D. O.; Henricks, J. D.

    1979-03-01

    The report describes the procedures used by Argonne National Laboratory to sample surface coal mine effluents in order to obtain field and laboratory data on 110 organic compounds or classes of compounds and 14 metals and minerals that are known as priority pollutants, plus 5-day biochemical oxygen demand (BOD/sub 5/), total organic carbon (TOC), chemical oxygen demand (COD), total dissolved solids (TDS), and total suspended solids (TSS). Included are directions for preparation of sampling containers and equipment, methods of sampling and sample preservation, and field and laboratory protocols, including chain-of-custody procedures. Actual analytical procedures are not described, but their sources are referenced.

  10. Detection of Campylobacter in human faecal samples in Fiji.

    Science.gov (United States)

    Devi, Aruna; Wilkinson, Jenny; Mahony, Timothy; Vanniasinkam, Thiru

    2014-01-01

    Data on campylobacteriosis in developed countries are well documented; in contrast, few studies on campylobacteriosis have been conducted in developing countries. This study was undertaken to test for Campylobacter in human faecal samples sent to the two major pathology laboratories in Fiji. A total of 408 diarrhoeal faecal samples were collected from the two major hospital pathology laboratories in Central Fiji (Suva) and Western Fiji (Lautoka) between December 2012 and February 2013 and from June to July 2013. Samples were analysed for the presence of Campylobacter using polymerase chain reaction (PCR) based methods. Campylobacter was detected in 241/408 (59.1%) of samples tested using PCR. Samples from children aged less than five accounted for 21.6% of positive cases. Campylobacter was detected in 59.1% of diarrhoeal samples collected from the two main laboratories in Fiji. A high proportion of children under five years with Campylobacter has been reported in other countries and could be due to parents being more likely to seek medical attention. Further studies are required to confirm the species of Campylobacter that are predominantly associated with gastroenteritis in Fiji.

  11. METHODS FOR DETERMINING AGITATOR MIXING REQUIREMENTS FOR A MIXING and SAMPLING FACILITY TO FEED WTP (WASTE TREATMENT PLANT)

    International Nuclear Information System (INIS)

    Griffin, P.W.

    2009-01-01

    The following report is a summary of work conducted to evaluate the ability of existing correlative techniques and alternative methods to accurately estimate impeller speed and power requirements for mechanical mixers proposed for use in a mixing and sampling facility (MSF). The proposed facility would accept high level waste sludges from Hanford double-shell tanks and feed uniformly mixed high level waste to the Waste Treatment Plant. Numerous methods are evaluated and discussed, and resulting recommendations provided.

  12. Total cardiovascular disease risk assessment: a review.

    LENUS (Irish Health Repository)

    Cooney, Marie Therese

    2011-09-01

    The high risk strategy for the prevention of cardiovascular disease (CVD) requires an assessment of an individual\\'s total CVD risk so that the most intensive risk factor management can be directed towards those at highest risk. Here we review developments in the assessment and estimation of total CVD risk.

  13. Sample normalization methods in quantitative metabolomics.

    Science.gov (United States)

    Wu, Yiman; Li, Liang

    2016-01-22

    To reveal metabolomic changes caused by a biological event in quantitative metabolomics, it is critical to use an analytical tool that can perform accurate and precise quantification to examine the true concentration differences of individual metabolites found in different samples. A number of steps are involved in metabolomic analysis including pre-analytical work (e.g., sample collection and storage), analytical work (e.g., sample analysis) and data analysis (e.g., feature extraction and quantification). Each one of them can influence the quantitative results significantly and thus should be performed with great care. Among them, the total sample amount or concentration of metabolites can be significantly different from one sample to another. Thus, it is critical to reduce or eliminate the effect of total sample amount variation on quantification of individual metabolites. In this review, we describe the importance of sample normalization in the analytical workflow with a focus on mass spectrometry (MS)-based platforms, discuss a number of methods recently reported in the literature and comment on their applicability in real world metabolomics applications. Sample normalization has been sometimes ignored in metabolomics, partially due to the lack of a convenient means of performing sample normalization. We show that several methods are now available and sample normalization should be performed in quantitative metabolomics where the analyzed samples have significant variations in total sample amounts. Copyright © 2015 Elsevier B.V. All rights reserved.

  14. Achieving Accuracy Requirements for Forest Biomass Mapping: A Data Fusion Method for Estimating Forest Biomass and LiDAR Sampling Error with Spaceborne Data

    Science.gov (United States)

    Montesano, P. M.; Cook, B. D.; Sun, G.; Simard, M.; Zhang, Z.; Nelson, R. F.; Ranson, K. J.; Lutchke, S.; Blair, J. B.

    2012-01-01

    The synergistic use of active and passive remote sensing (i.e., data fusion) demonstrates the ability of spaceborne light detection and ranging (LiDAR), synthetic aperture radar (SAR) and multispectral imagery for achieving the accuracy requirements of a global forest biomass mapping mission. This data fusion approach also provides a means to extend 3D information from discrete spaceborne LiDAR measurements of forest structure across scales much larger than that of the LiDAR footprint. For estimating biomass, these measurements mix a number of errors including those associated with LiDAR footprint sampling over regional - global extents. A general framework for mapping above ground live forest biomass (AGB) with a data fusion approach is presented and verified using data from NASA field campaigns near Howland, ME, USA, to assess AGB and LiDAR sampling errors across a regionally representative landscape. We combined SAR and Landsat-derived optical (passive optical) image data to identify forest patches, and used image and simulated spaceborne LiDAR data to compute AGB and estimate LiDAR sampling error for forest patches and 100m, 250m, 500m, and 1km grid cells. Forest patches were delineated with Landsat-derived data and airborne SAR imagery, and simulated spaceborne LiDAR (SSL) data were derived from orbit and cloud cover simulations and airborne data from NASA's Laser Vegetation Imaging Sensor (L VIS). At both the patch and grid scales, we evaluated differences in AGB estimation and sampling error from the combined use of LiDAR with both SAR and passive optical and with either SAR or passive optical alone. This data fusion approach demonstrates that incorporating forest patches into the AGB mapping framework can provide sub-grid forest information for coarser grid-level AGB reporting, and that combining simulated spaceborne LiDAR with SAR and passive optical data are most useful for estimating AGB when measurements from LiDAR are limited because they minimized

  15. A simple vibrating sample magnetometer for macroscopic samples

    Science.gov (United States)

    Lopez-Dominguez, V.; Quesada, A.; Guzmán-Mínguez, J. C.; Moreno, L.; Lere, M.; Spottorno, J.; Giacomone, F.; Fernández, J. F.; Hernando, A.; García, M. A.

    2018-03-01

    We here present a simple model of a vibrating sample magnetometer (VSM). The system allows recording magnetization curves at room temperature with a resolution of the order of 0.01 emu and is appropriated for macroscopic samples. The setup can be mounted with different configurations depending on the requirements of the sample to be measured (mass, saturation magnetization, saturation field, etc.). We also include here examples of curves obtained with our setup and comparison curves measured with a standard commercial VSM that confirms the reliability of our device.

  16. Effective sample labeling

    International Nuclear Information System (INIS)

    Rieger, J.T.; Bryce, R.W.

    1990-01-01

    Ground-water samples collected for hazardous-waste and radiological monitoring have come under strict regulatory and quality assurance requirements as a result of laws such as the Resource Conservation and Recovery Act. To comply with these laws, the labeling system used to identify environmental samples had to be upgraded to ensure proper handling and to protect collection personnel from exposure to sample contaminants and sample preservatives. The sample label now used as the Pacific Northwest Laboratory is a complete sample document. In the event other paperwork on a labeled sample were lost, the necessary information could be found on the label

  17. Chemometrics methods for the investigation of methylmercury and total mercury contamination in mollusks samples collected from coastal sites along the Chinese Bohai Sea.

    Science.gov (United States)

    Yawei, Wang; Lina, Liang; Jianbo, Shi; Guibin, Jiang

    2005-06-01

    The development and application of chemometrics methods, principal component analysis (PCA), cluster analysis and correlation analysis for the determination of methylmercury (MeHg) and total mecury (HgT) in gastropod and bivalve species collected from eight coastal sites along the Chinese Bohai Sea are described. HgT is directly determined by atomic fluorescence spectrometry (AFS), while MeHg is measured by a laboratory established high performance liquid chromatography-atomic fluorescence spectrometry system (HPLC-AFS). One-way ANOVA and cluster analysis indicated that the bioaccumulation of Rap to accumulate Hg was significantly (P<0.05) different from other mollusks. Correlation analysis shows that there is linear relationship between MeHg and HgT in mollusks samples collected from coastal sites along the Chinese Bohai Sea, while in mollusks samples collected from Hongqiao market in Beijing City, there is not any linear relationship.

  18. Hanford analytical services quality assurance requirements documents. Volume 1: Administrative Requirements

    International Nuclear Information System (INIS)

    Hyatt, J.E.

    1997-01-01

    Hanford Analytical Services Quality Assurance Requirements Document (HASQARD) is issued by the Analytical Services, Program of the Waste Management Division, US Department of Energy (US DOE), Richland Operations Office (DOE-RL). The HASQARD establishes quality requirements in response to DOE Order 5700.6C (DOE 1991b). The HASQARD is designed to meet the needs of DOE-RL for maintaining a consistent level of quality for sampling and field and laboratory analytical services provided by contractor and commercial field and laboratory analytical operations. The HASQARD serves as the quality basis for all sampling and field/laboratory analytical services provided to DOE-RL through the Analytical Services Program of the Waste Management Division in support of Hanford Site environmental cleanup efforts. This includes work performed by contractor and commercial laboratories and covers radiological and nonradiological analyses. The HASQARD applies to field sampling, field analysis, and research and development activities that support work conducted under the Hanford Federal Facility Agreement and Consent Order Tri-Party Agreement and regulatory permit applications and applicable permit requirements described in subsections of this volume. The HASQARD applies to work done to support process chemistry analysis (e.g., ongoing site waste treatment and characterization operations) and research and development projects related to Hanford Site environmental cleanup activities. This ensures a uniform quality umbrella to analytical site activities predicated on the concepts contained in the HASQARD. Using HASQARD will ensure data of known quality and technical defensibility of the methods used to obtain that data. The HASQARD is made up of four volumes: Volume 1, Administrative Requirements; Volume 2, Sampling Technical Requirements; Volume 3, Field Analytical Technical Requirements; and Volume 4, Laboratory Technical Requirements. Volume 1 describes the administrative requirements

  19. Sample Length Affects the Reliability of Language Sample Measures in 3-Year-Olds: Evidence from Parent-Elicited Conversational Samples

    Science.gov (United States)

    Guo, Ling-Yu; Eisenberg, Sarita

    2015-01-01

    Purpose: The goal of this study was to investigate the extent to which sample length affected the reliability of total number of words (TNW), number of different words (NDW), and mean length of C-units in morphemes (MLCUm) in parent-elicited conversational samples for 3-year-olds. Method: Participants were sixty 3-year-olds. A 22-min language…

  20. Sensitive determination of total particulate phosphorus and particulate inorganic phosphorus in seawater using liquid waveguide spectrophotometry.

    Science.gov (United States)

    Ehama, Makoto; Hashihama, Fuminori; Kinouchi, Shinko; Kanda, Jota; Saito, Hiroaki

    2016-06-01

    Determining the total particulate phosphorus (TPP) and particulate inorganic phosphorus (PIP) in oligotrophic oceanic water generally requires the filtration of a large amount of water sample. This paper describes methods that require small filtration volumes for determining the TPP and PIP concentrations. The methods were devised by validating or improving conventional sample processing and by applying highly sensitive liquid waveguide spectrophotometry to the measurements of oxidized or acid-extracted phosphate from TPP and PIP, respectively. The oxidation of TPP was performed by a chemical wet oxidation method using 3% potassium persulfate. The acid extraction of PIP was initially carried out based on the conventional extraction methodology, which requires 1M HCl, followed by the procedure for decreasing acidity. While the conventional procedure for acid removal requires a ten-fold dilution of the 1M HCl extract with purified water, the improved procedure proposed in this study uses 8M NaOH solution for neutralizing 1M HCl extract in order to reduce the dilution effect. An experiment for comparing the absorbances of the phosphate standard dissolved in 0.1M HCl and of that dissolved in a neutralized solution [1M HCl: 8M NaOH=8:1 (v:v)] exhibited a higher absorbance in the neutralized solution. This indicated that the improved procedure completely removed the acid effect, which reduces the sensitivity of the phosphate measurement. Application to an ultraoligotrophic water sample showed that the TPP concentration in a 1075mL-filtered sample was 8.4nM with a coefficient of variation (CV) of 4.3% and the PIP concentration in a 2300mL-filtered sample was 1.3nM with a CV of 6.1%. Based on the detection limit (3nM) of the sensitive phosphate measurement and the ambient TPP and PIP concentrations of the ultraoligotrophic water, the minimum filtration volumes required for the detection of TPP and PIP were estimated to be 15 and 52mL, respectively. Copyright © 2016

  1. Is Mars Sample Return Required Prior to Sending Humans to Mars?

    Science.gov (United States)

    Carr, Michael; Abell, Paul; Allwood, Abigail; Baker, John; Barnes, Jeff; Bass, Deborah; Beaty, David; Boston, Penny; Brinkerhoff, Will; Budney, Charles; hide

    2012-01-01

    Prior to potentially sending humans to the surface of Mars, it is fundamentally important to return samples from Mars. Analysis in Earth's extensive scientific laboratories would significantly reduce the risk of human Mars exploration and would also support the science and engineering decisions relating to the Mars human flight architecture. The importance of measurements of any returned Mars samples range from critical to desirable, and in all cases these samples will would enhance our understanding of the Martian environment before potentially sending humans to that alien locale. For example, Mars sample return (MSR) could yield information that would enable human exploration related to 1) enabling forward and back planetary protection, 2) characterizing properties of Martian materials relevant for in situ resource utilization (ISRU), 3) assessing any toxicity of Martian materials with respect to human health and performance, and 4) identifying information related to engineering surface hazards such as the corrosive effect of the Martian environment. In addition, MSR would be engineering 'proof of concept' for a potential round trip human mission to the planet, and a potential model for international Mars exploration.

  2. Advances in modern sample preparation techniques using microwaves assisted chemistry for metal species determination (W1)

    International Nuclear Information System (INIS)

    Ponard, O.F.X.

    2002-01-01

    Full text: Sample preparation has long been the bottleneck of environmental analysis for both total and species specific analysis. Digestion, extraction and preparation of the analytes are relying on a series of chemical reactions. The introduction of microwave assisted sample preparation has first been viewed as a mean to accelerate the kinetics of digestion of the matrix for total elements and fast samples preparation procedures. However, the extensive development and success of microwave digestion procedures in total elemental analysis has now allowed to have a larger insight of the perspectives offered by this technique. Microwave technologies now offer to have a precise control of the temperature and indirectly control the reaction kinetics taking place during the sample preparation procedures. Microwave assisted chemistry permits to perform simultaneously the fundamental steps required for metal species extraction and derivatization. The number of sample preparation steps used for organotin or organomercury species have been reduced to one and the total time of sample preparation brought down for a few hours to some minutes. Further, the developments of GC/ICP/MS techniques allow to routinely use speciated isotopic dilution methods has internal probe of the chemical reactions. These new approaches allow us to use the addition of the labeled species for isotopic dilution as a mean to evaluate and follow the chemical processes taking place during the extraction procedure. These procedures will help us to understand and check for the stability of the analytes during the chemistry of the sample preparation procedure and bring some insights of the chemistry taking place during the extraction. Understanding the different mechanisms involved in the sample preparation steps will allow us in return to further improve all theses procedures and bring us to the horizon of 'on-line sample preparation and detection'. (author)

  3. Tranexamic acid versus aminocaproic acid for blood management after total knee and total hip arthroplasty: A systematic review and meta-analysis.

    Science.gov (United States)

    Liu, Qiuliang; Geng, Peishuo; Shi, Longyan; Wang, Qi; Wang, Pengliang

    2018-06-01

    To compare the efficacy and safety of tranexamic acid and aminocaproic acid for reducing blood loss and transfusion requirements after total knee and total hip arthroplasty. We conduct electronic searches of Medline (1966-2017.11), PubMed (1966-2017.11), Embase (1980-2017.11), ScienceDirect (1985-2017.11) and the Cochrane Library (1900-2017.11). The primary outcomes, including total blood loss, hemoglobin decline and transfusion requirements. Secondary outcomes include length of hospital stay and postoperative complications such as the incidence of deep vein thrombosis and pulmonary embolism. Each outcome is combined and calculated using the statistical software STATA 12.0. Fixed/random effect model is adopted based on the heterogeneity tested by I 2 statistic. A total of 1714 patients are analyzed across three randomized controlled trials (RCTs) and one non-RCT. The present meta-analysis reveals that TXA is associated with a significantly reduction of total blood loss and postoperative hemoglobin drop compared with EACA. No significant differences are identified in terms of transfusion rates, length of hospital stay, and the incidence of postoperative complications. Although total blood loss and postoperative hemoglobin drop are significant greater in EACA groups, there is no significant difference between TXA and EACA groups in terms of transfusion rates. Based on the current evidence available, higher quality RCTs are still required for further research. Copyright © 2018 IJS Publishing Group Ltd. Published by Elsevier Ltd. All rights reserved.

  4. Quantitative determination of total cesium in highly active liquid waste by using liquid electrode plasma optical emission spectrometry.

    Science.gov (United States)

    Do, Van-Khoai; Yamamoto, Masahiko; Taguchi, Shigeo; Takamura, Yuzuru; Surugaya, Naoki; Kuno, Takehiko

    2018-06-01

    A sensitive analytical method for determination of total cesium (Cs) in highly active liquid waste (HALW) by using modified liquid electrode plasma optical emission spectrometry (LEP-OES) is developed in this study. The instrument is modified to measure radioactive samples in a glove box. The effects of important factors, including pulsed voltage sequence and nitric acid concentration, on the emission of Cs are investigated. The limit of detection (LOD) and limit of quantification (LOQ) are 0.005 mg/L and 0.02 mg/L, respectively. The achieved LOD is one order lower than that of recently developed spectroscopic methods using liquid discharge plasma. The developed method is validated by subjecting a simulated HALW sample to inductively coupled plasma mass spectrometry (ICP-MS). The recoveries obtained from a spike-and-recovery test are 96-102%, implying good accuracy. The method is successfully applied to the quantification of Cs in a real HALW sample at the Tokai reprocessing plant in Japan. Apart from dilution and filtration of the HALW sample, no other pre-treatment process is required. The results agree well with the values obtained using gamma spectrometry. The developed method offers a reliable technique for rapid analysis of total Cs in HALW samples. Copyright © 2018 Elsevier B.V. All rights reserved.

  5. Sampling strategies in antimicrobial resistance monitoring: evaluating how precision and sensitivity vary with the number of animals sampled per farm.

    Directory of Open Access Journals (Sweden)

    Takehisa Yamamoto

    Full Text Available Because antimicrobial resistance in food-producing animals is a major public health concern, many countries have implemented antimicrobial monitoring systems at a national level. When designing a sampling scheme for antimicrobial resistance monitoring, it is necessary to consider both cost effectiveness and statistical plausibility. In this study, we examined how sampling scheme precision and sensitivity can vary with the number of animals sampled from each farm, while keeping the overall sample size constant to avoid additional sampling costs. Five sampling strategies were investigated. These employed 1, 2, 3, 4 or 6 animal samples per farm, with a total of 12 animals sampled in each strategy. A total of 1,500 Escherichia coli isolates from 300 fattening pigs on 30 farms were tested for resistance against 12 antimicrobials. The performance of each sampling strategy was evaluated by bootstrap resampling from the observational data. In the bootstrapping procedure, farms, animals, and isolates were selected randomly with replacement, and a total of 10,000 replications were conducted. For each antimicrobial, we observed that the standard deviation and 2.5-97.5 percentile interval of resistance prevalence were smallest in the sampling strategy that employed 1 animal per farm. The proportion of bootstrap samples that included at least 1 isolate with resistance was also evaluated as an indicator of the sensitivity of the sampling strategy to previously unidentified antimicrobial resistance. The proportion was greatest with 1 sample per farm and decreased with larger samples per farm. We concluded that when the total number of samples is pre-specified, the most precise and sensitive sampling strategy involves collecting 1 sample per farm.

  6. Sobredentadura total superior implantosoportada Superior total overdenture on implants

    Directory of Open Access Journals (Sweden)

    Luis Orlando Rodríguez García

    2010-06-01

    Full Text Available Se presenta un caso de un paciente desdentado total superior, rehabilitado en la consulta de implantología de la Clínica "Pedro Ortiz" del municipio Habana del Este en Ciudad de La Habana, Cuba, en el año 2009, mediante prótesis sobre implantes osteointegrados, técnica que se ha incorporado a la práctica estomatológica en Cuba como alternativa al tratamiento convencional en los pacientes desdentados totales. Se siguió un protocolo que comprendió una fase quirúrgica, procedimiento con o sin realización de colgajo y carga precoz o inmediata. Se presenta un paciente masculino de 56 años de edad, que acudió a la consulta multidisciplinaria, preocupado, porque se le habían elaborado tres prótesis en los últimos dos años y ninguna reunía los requisitos de retención que él necesitaba para sentirse seguro y cómodo con las mismas. El resultado final fue la satisfacción total del paciente, con el mejoramiento de la calidad estética y funcional.This is the case of a total maxilla edentulous patient seen in consultation of the "Pedro Ortíz" Clinic Implant of Habana del Este municipality in 2009 and con rehabilitation by prosthesis over osteointegration implants added to stomatology practice in Cuba as an alternative to conventional treatment in patients totally edentulous. We follow a protocol including a surgery or surgical phase, technique without or with flap creation and early or immediate load. This is a male patient aged 56 came to our multidisciplinary consultation worried because he had three prostheses in last two years and any fulfilled the requirements of retention to feel safe and comfortable with prostheses. The final result was the total satisfaction of rehabilitated patient improving its aesthetic and functional quality.

  7. Total reflection X-ray spectroscopy as a rapid analytical method for uranium determination in drainage water

    International Nuclear Information System (INIS)

    Matsuyama, Tsugufumi; Sakai, Yasuhiro; Izumoto, Yukie; Imaseki, Hitoshi; Hamano, Tsuyoshi; Yoshii, Hiroshi

    2017-01-01

    Uranium concentrations in drainage water are typically determined by α-spectrometry. However, due to the low specific radioactivity of uranium, the evaporation of large volumes of drainage water, followed by several hours of measurements, is required. Thus, the development of a rapid and simple detection method for uranium in drainage water would enhance the operation efficiency of radiation control workers. We herein propose a novel methodology based on total reflection X-ray fluorescence (TXRF) for the measurement of uranium in contaminated water. TXRF is a particularly desirable method for the rapid and simple evaluation of uranium in contaminated water, as chemical pretreatment of the sample solution is not necessary, measurement times are typically several seconds, and the required sample volume is low. We herein employed sample solutions containing several different concentrations of uranyl acetate with yttrium as an internal standard. The solutions were placed onto sample holders, and were dried prior to TXRF measurements. The relative intensity, otherwise defined as the net intensity ratio of the Lα peak of uranium to the Kα peak of yttrium, was directly proportional to the uranium concentration. Using this method, a TXRF detection limit for uranium in contaminated water of 0.30 μg/g was achieved. (author)

  8. Surfactant-enhanced spectrofluorimetric determination of total aflatoxins from wheat samples after magnetic solid-phase extraction using modified Fe3O4 nanoparticles

    Science.gov (United States)

    Manafi, Mohammad Hanif; Allahyari, Mehdi; Pourghazi, Kamyar; Amoli-Diva, Mitra; Taherimaslak, Zohreh

    2015-07-01

    The extraction and preconcentration of total aflatoxins (including aflatoxin B1, B2, G1, and G2) using magnetic nanoparticles based solid phase extraction (MSPE) followed by surfactant-enhanced spectrofluorimetric detection was proposed. Ethylene glycol bis-mercaptoacetate modified silica coated Fe3O4 nanoparticles as an efficient antibody-free adsorbent was successfully applied to extract aflatoxins from wheat samples. High surface area and strong magnetization properties of magnetic nanoparticles were utilized to achieve high enrichment factor (97), and satisfactory recoveries (92-105%) using only 100 mg of the adsorbent. Furthermore, the fast separation time (less than 10 min) avoids many time-consuming cartridge loading or column-passing procedures accompany with the conventional SPE. In determination step, signal enhancement was performed by formation of Triton X-100 micelles around the analytes in 15% (v/v) acetonitrile-water which dramatically increase the sensitivity of the method. Main factors affecting the extraction efficiency and signal enhancement of the analytes including pH of sample solution, desorption conditions, extraction time, sample volume, adsorbent amount, surfactant concentration and volume and time of micelle formation were evaluated and optimized. Under the optimum conditions, wide linear range of 0.1-50 ng mL-1 with low detection limit of 0.03 ng mL-1 were obtained. The developed method was successfully applied to the extraction and preconcentration of aflatoxins in three commercially available wheat samples and the results were compared with the official AOAC method.

  9. Total mercury of selected fish species from Laguna de Bay

    International Nuclear Information System (INIS)

    Relon, Milagros Lontoc

    1996-01-01

    Dalag Ophicephalus striatus Block, kanduli Arius thalassinus Ruppell, bia Amblygobius phalaena Cuvier et Valenciennes and tilapia Tilapia nilotica Linnnaeus collected from Laguna de Bay between Taguig and Binangonan area in August 1989 to July 1990 were analyzed for total mercury by atomic absorption spectrometry. The highest metal concentration in soft muscle tissue was observed in Dalag followed by kanduli, less in bia and least in tilapia with mean values of 0.021, 0.020, 0.013, and 0.008 ug/g, respectively. Analysis using two-way ANOVA showed a significant difference in the mean total mercury in ug/g in the difference fish samples, among the different months and the interaction between these two variables. Mean total mercury of the four fish samples were significantly higher in April than in October. The results show that the levels of total mercury in the fish samples are below the World Health Organization maximum tolerable consumption of mercury in food of 300 ug or 0.03 mg of total mercury per week. (author)

  10. Integrating total quality management principles with the requirements of DOE Order 5700.6C

    Energy Technology Data Exchange (ETDEWEB)

    Hedges, D. [Scientific Ecology Group, Inc. (United States)

    1993-03-01

    The Department of Energy has recently required its field offices, contractors, and subcontractors to implement DOE Order 5700.6C, ``Quality Assurance,`` for all work on waste management contracts. The order restructures the 18 criteria of NQA-1 and focuses on the role of management in achieving and assuring quality, performance of activities to achieve and assure quality, and management`s assessment of its performance for the purpose of identifying improvements to be made. The DOE order also introduces elements of the total quality management (TQM) philosophy, which were not present in DOE Order 5700.6B. The research community within DOE has recently issued a document entitled DOE Order 5700.6C Implementation Guide, which is more explicit about the integration of TQM principles with the implementation of DOE Order 5700.6C in research facilities. The Environmental Protection Agency is sponsoring a quality assurance standard (ANSI/ASQC E-4) to replace EPA`s QAMS 005/80. The new standard is consistent with DOE Order 5700.6C, and it also stresses the integration of TQM principles within the quality assurance process. This paper discusses the intent and philosophy of the 10 criteria of the new DOE order, the status of ANSI/ASQC E-4, and how to effectively integrate TQM principles into the quality assurance process as the conversion is made from NQA-1 to DOE Order 5700.6C. The purpose and value of DOE Order 5700.6C Implementation Guide for research will also be discussed.

  11. Impurities determination in uranium eluates by total reflection X-ray fluorescence

    International Nuclear Information System (INIS)

    Vazquez, Cristina; Bellavigna, Horacio J.; Eppis, Maria R.; Ramella, Jose L.

    1999-01-01

    The chemical control of impurities in nuclear materials is indispensable in order to assure an efficient operation of the reactors. The maximum concentration admitted depends of the elements and in most cases are in the parts per billion range. Conventional analytical methods require a pre-concentration treatment of the sample and a previous separation of the matrix (uranium). This paper investigates the use of the total reflection X-ray fluorescence as an alternative methodology for the determination of impurities in nuclear materials, namely K, Ca, Ti, Cr, Mn, Fe, Ni, Cu and As. The detection limits obtained were in the range of 0.1 to 20 ng/ml for a 1000 seconds counting time. (author)

  12. Mars Sample Handling Functionality

    Science.gov (United States)

    Meyer, M. A.; Mattingly, R. L.

    2018-04-01

    The final leg of a Mars Sample Return campaign would be an entity that we have referred to as Mars Returned Sample Handling (MRSH.) This talk will address our current view of the functional requirements on MRSH, focused on the Sample Receiving Facility (SRF).

  13. Hanford site transuranic waste sampling plan

    International Nuclear Information System (INIS)

    GREAGER, T.M.

    1999-01-01

    This sampling plan (SP) describes the selection of containers for sampling of homogeneous solids and soil/gravel and for visual examination of transuranic and mixed transuranic (collectively referred to as TRU) waste generated at the U.S. Department of Energy (DOE) Hanford Site. The activities described in this SP will be conducted under the Hanford Site TRU Waste Certification Program. This SP is designed to meet the requirements of the Transuranic Waste Characterization Quality Assurance Program Plan (CAO-94-1010) (DOE 1996a) (QAPP), site-specific implementation of which is described in the Hanford Site Transuranic Waste Characterization Program Quality Assurance Project Plan (HNF-2599) (Hanford 1998b) (QAPP). The QAPP defines the quality assurance (QA) requirements and protocols for TRU waste characterization activities at the Hanford Site. In addition, the QAPP identifies responsible organizations, describes required program activities, outlines sampling and analysis strategies, and identifies procedures for characterization activities. The QAPP identifies specific requirements for TRU waste sampling plans. Table 1-1 presents these requirements and indicates sections in this SP where these requirements are addressed

  14. Hepatitis B virus DNA quantification with the three-in-one (3io) method allows accurate single-step differentiation of total HBV DNA and cccDNA in biopsy-size liver samples.

    Science.gov (United States)

    Taranta, Andrzej; Tien Sy, Bui; Zacher, Behrend Johan; Rogalska-Taranta, Magdalena; Manns, Michael Peter; Bock, Claus Thomas; Wursthorn, Karsten

    2014-08-01

    Hepatitis B virus (HBV) replicates via reverse transcription converting its partially double stranded genome into the covalently closed circular DNA (cccDNA). The long-lasting cccDNA serves as a replication intermediate in the nuclei of hepatocytes. It is an excellent, though evasive, parameter for monitoring the course of liver disease and treatment efficiency. To develop and test a new approach for HBV DNA quantification in serum and small-size liver samples. The p3io plasmid contains an HBV fragment and human β-actin gene (hACTB) as a standard. Respective TaqMan probes were labeled with different fluorescent dyes. A triplex real-time PCR for simultaneous quantification of total HBV DNA, cccDNA and hACTB could be established. Three-in-one method allows simultaneous analysis of 3 targets with a lower limit of quantification of 48 copies per 20 μl PCR reaction and a wide range of linearity (R(2)>0.99, pDNA samples from HBV infected patients. Total HBV DNA and cccDNA could be quantified in 32 and 22 of 33 FFPE preserved liver specimens, respectively. Total HBV DNA concentrations quantified by the 3io method remained comparable with Cobas TaqMan HBV Test v2.0. The three-in-one protocol allows the single step quantification of viral DNA in samples from different sources. Therefore lower sample input, faster data acquisition, a lowered error and significantly lower costs are the advantages of the method. Copyright © 2014 Elsevier B.V. All rights reserved.

  15. Importance of salt in the production matrix of the efficiency curve for the determination of the total alpha activity in water samples; Importancia de la matriz salina en la fabricacion de la curva de eficiencia para la determinacion del indice de actividad alfa total en muestras de agua

    Energy Technology Data Exchange (ETDEWEB)

    Baeza, A.; Corbacho, J. A.

    2011-07-01

    The determination of total alpha activity by the evaporation method allows obtaining, from a quick and inexpensive technique, the order of magnitude of the total activity of all alpha emitters present in a sample of water. This study shows that the detection efficiency curve varies significantly depending on the sodium salt is used to manufacture calibration and/or reference radionuclide used. (Author)

  16. Relative efficiency and sample size for cluster randomized trials with variable cluster sizes.

    Science.gov (United States)

    You, Zhiying; Williams, O Dale; Aban, Inmaculada; Kabagambe, Edmond Kato; Tiwari, Hemant K; Cutter, Gary

    2011-02-01

    The statistical power of cluster randomized trials depends on two sample size components, the number of clusters per group and the numbers of individuals within clusters (cluster size). Variable cluster sizes are common and this variation alone may have significant impact on study power. Previous approaches have taken this into account by either adjusting total sample size using a designated design effect or adjusting the number of clusters according to an assessment of the relative efficiency of unequal versus equal cluster sizes. This article defines a relative efficiency of unequal versus equal cluster sizes using noncentrality parameters, investigates properties of this measure, and proposes an approach for adjusting the required sample size accordingly. We focus on comparing two groups with normally distributed outcomes using t-test, and use the noncentrality parameter to define the relative efficiency of unequal versus equal cluster sizes and show that statistical power depends only on this parameter for a given number of clusters. We calculate the sample size required for an unequal cluster sizes trial to have the same power as one with equal cluster sizes. Relative efficiency based on the noncentrality parameter is straightforward to calculate and easy to interpret. It connects the required mean cluster size directly to the required sample size with equal cluster sizes. Consequently, our approach first determines the sample size requirements with equal cluster sizes for a pre-specified study power and then calculates the required mean cluster size while keeping the number of clusters unchanged. Our approach allows adjustment in mean cluster size alone or simultaneous adjustment in mean cluster size and number of clusters, and is a flexible alternative to and a useful complement to existing methods. Comparison indicated that we have defined a relative efficiency that is greater than the relative efficiency in the literature under some conditions. Our measure

  17. Total, added, and free sugars: are restrictive guidelines science-based or achievable?

    Science.gov (United States)

    Erickson, Jennifer; Slavin, Joanne

    2015-04-15

    Sugar consumption, especially added sugars, is under attack. Various government and health authorities have suggested new sugar recommendations and guidelines as low as 5% of total calories from free sugars. Definitions for total sugars, free sugars, and added sugars are not standardized, nor are there accepted nutrient databases for this information. Our objective was to measure total sugars and added sugars in sample meal plans created by the United States Department of Agriculture (USDA) and the Academy of Nutrition and Dietetics (AND). Utilizing the Nutrition Data System for Research (NDSR) nutritional database, results found that plans created by the USDA and AND averaged 5.1% and 3.1% calories from added sugar, 8.7% and 3.1% from free sugar, and 23.3% and 21.1% as total sugars respectively. Compliance with proposed added sugar recommendations would require strict dietary compliance and may not be sustainable for many Americans. Without an accepted definition and equation for calculating added sugar, added sugar recommendations are arbitrary and may reduce intakes of nutrient-rich, recommended foods, such as yogurt, whole grains, and tart fruits including cranberries, cherries, and grapefruit. Added sugars are one part of excess calorie intake; however, compliance with low added sugar recommendations may not be achievable for the general public.

  18. Total, Added, and Free Sugars: Are Restrictive Guidelines Science-Based or Achievable?

    Directory of Open Access Journals (Sweden)

    Jennifer Erickson

    2015-04-01

    Full Text Available Sugar consumption, especially added sugars, is under attack. Various government and health authorities have suggested new sugar recommendations and guidelines as low as 5% of total calories from free sugars. Definitions for total sugars, free sugars, and added sugars are not standardized, nor are there accepted nutrient databases for this information. Our objective was to measure total sugars and added sugars in sample meal plans created by the United States Department of Agriculture (USDA and the Academy of Nutrition and Dietetics (AND. Utilizing the Nutrition Data System for Research (NDSR nutritional database, results found that plans created by the USDA and AND averaged 5.1% and 3.1% calories from added sugar, 8.7% and 3.1% from free sugar, and 23.3% and 21.1% as total sugars respectively. Compliance with proposed added sugar recommendations would require strict dietary compliance and may not be sustainable for many Americans. Without an accepted definition and equation for calculating added sugar, added sugar recommendations are arbitrary and may reduce intakes of nutrient-rich, recommended foods, such as yogurt, whole grains, and tart fruits including cranberries, cherries, and grapefruit. Added sugars are one part of excess calorie intake; however, compliance with low added sugar recommendations may not be achievable for the general public.

  19. Studies and developments for the analysis of products of nuclear reprocessing plants with the help of the X-ray fluorescence analysis on totally reflecting sample holders (TXRF)

    International Nuclear Information System (INIS)

    Diercks, H.; Eggers, I.; Gibau, F.; Haarich, M.; Hastenteufel, S.; Haurand, M.; Knoechel, A.; Salow, H.

    1990-01-01

    Studies with inactive and active simulates of products of nuclear reprocessing plants show the suitability of the X-Ray Fluorescence Analysis on Totally Reflecting Sample Holders (TXRF), to detect the available elements simultaneously by direct measurements of specially prepared thin samples. High dilution enables in the most cases, to avoid working in hot cells and to carry out the analysis in glove boxes. The analysis of uranium products and great amounts of matrix elements containing solutions like LAW and MAW demands the separation of the matrix elements before TXRF measurement. Procedures for this task have been developed. The potential of the new analytical procedure was demonstrated by the analysis of two samples of highly diluted high active wastes. (orig.) With 65 refs., 20 tabs., 81 figs [de

  20. Novel Sample-handling Approach for XRD Analysis with Minimal Sample Preparation

    Science.gov (United States)

    Sarrazin, P.; Chipera, S.; Bish, D.; Blake, D.; Feldman, S.; Vaniman, D.; Bryson, C.

    2004-01-01

    Sample preparation and sample handling are among the most critical operations associated with X-ray diffraction (XRD) analysis. These operations require attention in a laboratory environment, but they become a major constraint in the deployment of XRD instruments for robotic planetary exploration. We are developing a novel sample handling system that dramatically relaxes the constraints on sample preparation by allowing characterization of coarse-grained material that would normally be impossible to analyze with conventional powder-XRD techniques.

  1. Measurement of conjugated linoleic acid (CLA) in CLA-rich soy oil by attenuated total reflectance-Fourier transform infrared spectroscopy (ATR-FTIR).

    Science.gov (United States)

    Kadamne, Jeta V; Jain, Vishal P; Saleh, Mohammed; Proctor, Andrew

    2009-11-25

    Conjugated linoleic acid (CLA) isomers in oils are currently measured as fatty acid methyl esters by a gas chromatography-flame ionization detector (GC-FID) technique, which requires approximately 2 h to complete the analysis. Hence, we aim to develop a method to rapidly determine CLA isomers in CLA-rich soy oil. Soy oil with 0.38-25.11% total CLA was obtained by photo-isomerization of 96 soy oil samples for 24 h. A sample was withdrawn at 30 min intervals with repeated processing using a second batch of oil. Six replicates of GC-FID fatty acid analysis were conducted for each oil sample. The oil samples were scanned using attenuated total reflectance-Fourier transform infrared spectroscopy (ATR-FTIR), and the spectrum was collected. Calibration models were developed using partial least-squares (PLS-1) regression using Unscrambler software. Models were validated using a full cross-validation technique and tested using samples that were not included in the calibration sample set. Measured and predicted total CLA, trans,trans CLA isomers, total mono trans CLA isomers, trans-10,cis-12 CLA, trans-9,cis-11 CLA and cis-10,trans-12 CLA, and cis-9,trans-11 CLA had cross-validated coefficients of determinations (R2v) of 0.97, 0.98, 0.97, 0.98, 0.97, and 0.99 and corresponding root-mean-square error of validation (RMSEV) of 1.14, 0.69, 0.27, 0.07, 0.14, and 0.07% CLA, respectively. The ATR-FTIR technique is a rapid and less expensive method for determining CLA isomers in linoleic acid photo-isomerized soy oil than GC-FID.

  2. Automated radioanalytical system incorporating microwave-assisted sample preparation, chemical separation, and online radiometric detection for the monitoring of total 99Tc in nuclear waste processing streams.

    Science.gov (United States)

    Egorov, Oleg B; O'Hara, Matthew J; Grate, Jay W

    2012-04-03

    An automated fluidic instrument is described that rapidly determines the total (99)Tc content of aged nuclear waste samples, where the matrix is chemically and radiologically complex and the existing speciation of the (99)Tc is variable. The monitor links microwave-assisted sample preparation with an automated anion exchange column separation and detection using a flow-through solid scintillator detector. The sample preparation steps acidify the sample, decompose organics, and convert all Tc species to the pertechnetate anion. The column-based anion exchange procedure separates the pertechnetate from the complex sample matrix, so that radiometric detection can provide accurate measurement of (99)Tc. We developed a preprogrammed spike addition procedure to automatically determine matrix-matched calibration. The overall measurement efficiency that is determined simultaneously provides a self-diagnostic parameter for the radiochemical separation and overall instrument function. Continuous, automated operation was demonstrated over the course of 54 h, which resulted in the analysis of 215 samples plus 54 hly spike-addition samples, with consistent overall measurement efficiency for the operation of the monitor. A sample can be processed and measured automatically in just 12.5 min with a detection limit of 23.5 Bq/mL of (99)Tc in low activity waste (0.495 mL sample volume), with better than 10% RSD precision at concentrations above the quantification limit. This rapid automated analysis method was developed to support nuclear waste processing operations planned for the Hanford nuclear site.

  3. Passive Sampling in Regulatory Chemical Monitoring of Nonpolar Organic Compounds in the Aquatic Environment

    DEFF Research Database (Denmark)

    Booij, Kees; Robinson, Craig D; Burgess, Robert M

    2016-01-01

    We reviewed compliance monitoring requirements in the European Union, the United States, and the Oslo-Paris Convention for the protection of the marine environment of the North-East Atlantic, and evaluated if these are met by passive sampling methods for nonpolar compounds. The strengths...... is the best available technology for chemical monitoring of nonpolar organic compounds. Key issues to be addressed by scientists and environmental managers are outlined....... and shortcomings of passive sampling are assessed for water, sediments, and biota. Passive water sampling is a suitable technique for measuring concentrations of freely dissolved compounds. This method yields results that are incompatible with the EU's quality standard definition in terms of total concentrations...

  4. Jenis Sample: Keuntungan dan Kerugiannya

    OpenAIRE

    Suprapto, Agus

    1994-01-01

    Sample is a part of a population that are used in a study for purposes of making estimation about the nature of the total population that is obtained with sampling technic. Sampling technic is more adventagous than cencus because it can reduce cost, time, and it can gather deeper information and more accurate data. It is useful to distinguish two major types of sampling technics. First, Prob bility sampling i.e. simple random sampling. Second, Non Probability sampling i.e. systematic sam­plin...

  5. Sampling optimization for printer characterization by direct search.

    Science.gov (United States)

    Bianco, Simone; Schettini, Raimondo

    2012-12-01

    Printer characterization usually requires many printer inputs and corresponding color measurements of the printed outputs. In this brief, a sampling optimization for printer characterization on the basis of direct search is proposed to maintain high color accuracy with a reduction in the number of characterization samples required. The proposed method is able to match a given level of color accuracy requiring, on average, a characterization set cardinality which is almost one-fourth of that required by the uniform sampling, while the best method in the state of the art needs almost one-third. The number of characterization samples required can be further reduced if the proposed algorithm is coupled with a sequential optimization method that refines the sample values in the device-independent color space. The proposed sampling optimization method is extended to deal with multiple substrates simultaneously, giving statistically better colorimetric accuracy (at the α = 0.05 significance level) than sampling optimization techniques in the state of the art optimized for each individual substrate, thus allowing use of a single set of characterization samples for multiple substrates.

  6. Sample summary report for ARG 1 pressure tube sample

    International Nuclear Information System (INIS)

    Belinco, C.

    2006-01-01

    The ARG 1 sample is made from an un-irradiated Zr-2.5% Nb pressure tube. The sample has 103.4 mm ID, 112 mm OD and approximately 500 mm length. A punch mark was made very close to one end of the sample. The punch mark indicates the 12 O'clock position and also identifies the face of the tube for making all the measurements. ARG 1 sample contains flaws on ID and OD surface. There was no intentional flaw within the wall of the pressure tube sample. Once the flaws are machined the pressure tube sample was covered from outside to hide the OD flaws. Approximately 50 mm length of pressure tube was left open at both the ends to facilitate the holding of sample in the fixtures for inspection. No flaw was machined in this zone of 50 mm on either end of the pressure tube sample. A total of 20 flaws were machined in ARG 1 sample. Out of these, 16 flaws were on the OD surface and the remaining 4 on the ID surface of the pressure tube. The flaws were characterized in to various groups like axial flaws, circumferential flaws, etc

  7. Total lead (Pb) concentration in oil shale ash samples based on correlation to isotope Pb-210 gamma-spectrometric measurements

    Energy Technology Data Exchange (ETDEWEB)

    Vaasma, T.; Kiisk, M.; Tkaczyk, A.H. [University of Tartu (Estonia); Bitjukova, L. [Tallinn University of Technology (Estonia)

    2014-07-01

    Estonian oil shale consists of organic matter and mineral material and contains various amounts of heavy metals as well as natural radionuclides (from the U-238 and Th-232 series and K-40). Previous research has shown that burning oil shale in the large power plants causes these radionuclides to become enriched in different ash fractions and be partially emitted to the atmosphere via fly ash and flue gases. The activity concentrations (Bq/kg) of these nuclides in different oil shale ash fractions vary significantly. This is influenced by the boiler parameters and combustion conditions - prevailing temperatures, pressure, ash circulating mechanisms, fly ash particle size, chemical composition of ash and coexistence of macro and micro components. As with radionuclides, various heavy metals remain concentrated in the ash fractions and are released to the atmosphere (over 20 tons of Pb per year from Estonian oil shale power plants). Lead is a heavy metal with toxic influence on the nervous system, reproductive system and different organs in human body. Depending on the exposure pathways, lead could pose a long term health hazard. Ash samples are highly heterogeneous and exhibit great variability in composition and particle size. Determining the lead concentration in ash samples by modern methods like inductively coupled plasma mass spectroscopy (ICP-MS), flame atomic absorption spectrometry (FAAS), graphite furnace atomic absorption spectroscopy (GFAAS) and other techniques often requires time consuming, multistage and complex chemical sample preparation. The list of possible methods to use is lengthy, but it is a challenge to choose a suitable one to meet measurement needs and practical considerations. The detection limits, capital costs and maintenance expenses vary between the instruments. This work presents the development of an alternative measurement technique for our oil shale ash samples. Oil shale ash was collected from different boilers using pulverized fuel

  8. Total selenium in irrigation drain inflows to the Salton Sea, California, April 2009

    Science.gov (United States)

    May, Thomas W.; Walther, Michael J.; Saiki, Michael K.; Brumbaugh, William G.

    2009-01-01

    This report presents the results for the final sampling period (April 2009) of a 4-year monitoring program to characterize selenium concentrations in selected irrigation drains flowing into the Salton Sea, California. Total selenium and total suspended solids were determined in water samples. Total selenium, percent total organic carbon, and particle size were determined in sediments. Mean total selenium concentrations in water ranged from 0.98 to 22.9 micrograms per liter. Total selenium concentrations in sediment ranged from 0.078 to 5.0 micrograms per gram dry weight.

  9. Sensitive radioimmunoassay of total thyroxine (T4) in horses using a simple extraction method.

    Science.gov (United States)

    Tangyuenyong, Siriwan; Nambo, Yasuo; Nagaoka, Kentaro; Tanaka, Tomomi; Watanabe, Gen

    2017-07-28

    Most thyroid hormone determinations in animals are based on immunoassays adapted from those used to test human samples, which may not reflect the actual values of thyroid hormone in horses because of the presence of binding proteins. The aims of the present study were i) to establish a novel radioimmunoassay (RIA) using a more simple and convenient method to separate binding proteins for the measurement of total thyroxine (T4) in horses and ii) to validate the assay by comparing total T4 concentrations in yearling horses raised in different climates. Blood samples were collected from trained yearlings in Hokkaido (temperate climate) and Miyazaki (subtropical climate) in Japan and from adult horses in estrus and diestrus. T4 was extracted from both serum and plasma using modified acid ethanol cryo-precipitation and sodium acetate ethanol methods. Circulating total T4 concentrations were determined by RIA. T4 concentration by sodium acetate ethanol was appropriately detectable rather than sodium salicylate method and was the same as for acid ethanol method. Furthermore, this sodium acetate ethanol method required fewer extraction steps than the other methods. Circulating T4 concentrations in yearlings were 225.98 ± 20.89 ng/ml, which was higher than the previous reference values. With respect to climate, T4 levels in Hokkaido yearlings tended to be higher than those in Miyazaki yearlings throughout the study period. These results indicated that this RIA protocol using a modified sodium acetate ethanol separation technique might be an appropriate tool for specific measurement of total T4 in horses.

  10. Nutrient Intake and Contribution of Home Enteral Nutrition to Meeting Nutritional Requirements after Oesophagectomy and Total Gastrectomy

    Science.gov (United States)

    Baker, Melanie L; Halliday, Vanessa; Robinson, Pauline; Smith, Karen; Bowrey, David J

    2017-01-01

    Background/Objectives This study evaluated nutrition after oesophago-gastric resection and the influence of home jejunostomy feeding in the six months after surgery. Subjects/Methods Data on nutritional intake and physiologic measures were collected as part of a randomised trial with measurements taken before and up to six months after surgery. Results 41 participants (32 oesophagectomy, 9 total gastrectomy) received home jejunostomy feeding (n=18) or usual care without feeding (n=23). At hospital discharge, oral intakes were adequate for energy and protein in 9% and 6% respectively. By three and six months, these values had increased to 61% & 55%, 94% & 77% respectively. Six participants (26%) who received usual care required rescue feeding. Six weeks after hospital discharge, energy intakes were met in those who received jejunal feeding due to the contribution of enteral nutrition. Jejunal feeding did not affect oral intake, being similar in both groups (fed: 77% estimated need, usual care: 79%). At three months, inadequate micronutrient intakes were seen in over one third. Compared to baseline values, six weeks after surgery, weight loss exceeding 5% was seen in 5/18 (28%) who received feeding, 14/17 (82%) who received usual care and 5/6 (83%) of those who required rescue feeding, p=0.002. Weight loss averaged 4.1% (fed), 10.4% (usual care) and 9.2% (rescue fed), p=0.004. These trends persisted out to six months. Conclusions Supplementary jejunostomy feeding made an important contribution to meeting nutrition after oesophago-gastric resection. Importantly, oral nutritional intake was not compromised dispelling the assertion that jejunal feeding deincentivises patients from eating. PMID:28656968

  11. Accurate determination of rates from non-uniformly sampled relaxation data

    Energy Technology Data Exchange (ETDEWEB)

    Stetz, Matthew A.; Wand, A. Joshua, E-mail: wand@upenn.edu [University of Pennsylvania Perelman School of Medicine, Johnson Research Foundation and Department of Biochemistry and Biophysics (United States)

    2016-08-15

    The application of non-uniform sampling (NUS) to relaxation experiments traditionally used to characterize the fast internal motion of proteins is quantitatively examined. Experimentally acquired Poisson-gap sampled data reconstructed with iterative soft thresholding are compared to regular sequentially sampled (RSS) data. Using ubiquitin as a model system, it is shown that 25 % sampling is sufficient for the determination of quantitatively accurate relaxation rates. When the sampling density is fixed at 25 %, the accuracy of rates is shown to increase sharply with the total number of sampled points until eventually converging near the inherent reproducibility of the experiment. Perhaps contrary to some expectations, it is found that accurate peak height reconstruction is not required for the determination of accurate rates. Instead, inaccuracies in rates arise from inconsistencies in reconstruction across the relaxation series that primarily manifest as a non-linearity in the recovered peak height. This indicates that the performance of an NUS relaxation experiment cannot be predicted from comparison of peak heights using a single RSS reference spectrum. The generality of these findings was assessed using three alternative reconstruction algorithms, eight different relaxation measurements, and three additional proteins that exhibit varying degrees of spectral complexity. From these data, it is revealed that non-linearity in peak height reconstruction across the relaxation series is strongly correlated with errors in NUS-derived relaxation rates. Importantly, it is shown that this correlation can be exploited to reliably predict the performance of an NUS-relaxation experiment by using three or more RSS reference planes from the relaxation series. The RSS reference time points can also serve to provide estimates of the uncertainty of the sampled intensity, which for a typical relaxation times series incurs no penalty in total acquisition time.

  12. Simulated Tempering Distributed Replica Sampling, Virtual Replica Exchange, and Other Generalized-Ensemble Methods for Conformational Sampling.

    Science.gov (United States)

    Rauscher, Sarah; Neale, Chris; Pomès, Régis

    2009-10-13

    Generalized-ensemble algorithms in temperature space have become popular tools to enhance conformational sampling in biomolecular simulations. A random walk in temperature leads to a corresponding random walk in potential energy, which can be used to cross over energetic barriers and overcome the problem of quasi-nonergodicity. In this paper, we introduce two novel methods: simulated tempering distributed replica sampling (STDR) and virtual replica exchange (VREX). These methods are designed to address the practical issues inherent in the replica exchange (RE), simulated tempering (ST), and serial replica exchange (SREM) algorithms. RE requires a large, dedicated, and homogeneous cluster of CPUs to function efficiently when applied to complex systems. ST and SREM both have the drawback of requiring extensive initial simulations, possibly adaptive, for the calculation of weight factors or potential energy distribution functions. STDR and VREX alleviate the need for lengthy initial simulations, and for synchronization and extensive communication between replicas. Both methods are therefore suitable for distributed or heterogeneous computing platforms. We perform an objective comparison of all five algorithms in terms of both implementation issues and sampling efficiency. We use disordered peptides in explicit water as test systems, for a total simulation time of over 42 μs. Efficiency is defined in terms of both structural convergence and temperature diffusion, and we show that these definitions of efficiency are in fact correlated. Importantly, we find that ST-based methods exhibit faster temperature diffusion and correspondingly faster convergence of structural properties compared to RE-based methods. Within the RE-based methods, VREX is superior to both SREM and RE. On the basis of our observations, we conclude that ST is ideal for simple systems, while STDR is well-suited for complex systems.

  13. Sample management implementation plan: Salt Repository Project

    International Nuclear Information System (INIS)

    1987-01-01

    The purpose of the Sample Management Implementation Plan is to define management controls and building requirements for handling materials collected during the site characterization of the Deaf Smith County, Texas, site. This work will be conducted for the US Department of Energy Salt Repository Project Office (SRPO). The plan provides for controls mandated by the US Nuclear Regulatory Commission and the US Environmental Protection Agency. Salt Repository Project (SRP) Sample Management will interface with program participants who request, collect, and test samples. SRP Sample Management will be responsible for the following: (1) preparing samples; (2) ensuring documentation control; (3) providing for uniform forms, labels, data formats, and transportation and storage requirements; and (4) identifying sample specifications to ensure sample quality. The SRP Sample Management Facility will be operated under a set of procedures that will impact numerous program participants. Requesters of samples will be responsible for definition of requirements in advance of collection. Sample requests for field activities will be approved by the SRPO, aided by an advisory group, the SRP Sample Allocation Committee. This document details the staffing, building, storage, and transportation requirements for establishing an SRP Sample Management Facility. Materials to be managed in the facility include rock core and rock discontinuities, soils, fluids, biota, air particulates, cultural artifacts, and crop and food stuffs. 39 refs., 3 figs., 11 tabs

  14. Sample size methodology

    CERN Document Server

    Desu, M M

    2012-01-01

    One of the most important problems in designing an experiment or a survey is sample size determination and this book presents the currently available methodology. It includes both random sampling from standard probability distributions and from finite populations. Also discussed is sample size determination for estimating parameters in a Bayesian setting by considering the posterior distribution of the parameter and specifying the necessary requirements. The determination of the sample size is considered for ranking and selection problems as well as for the design of clinical trials. Appropria

  15. The BD Onclarity HPV assay on SurePath collected samples meets the International Guidelines for Human Papillomavirus Test Requirements for Cervical Screening

    DEFF Research Database (Denmark)

    Ejegod, Ditte; Bottari, Fabio; Pedersen, Helle

    2016-01-01

    This study describes a validation of the BD Onclarity HPV (Onclarity) assay using the international guidelines for HPV test requirements for cervical cancer screening of women 30 years and above using Danish SurePath screening samples. The clinical specificity (0.90, 95% CI: 0.88-0.91) and sensit......This study describes a validation of the BD Onclarity HPV (Onclarity) assay using the international guidelines for HPV test requirements for cervical cancer screening of women 30 years and above using Danish SurePath screening samples. The clinical specificity (0.90, 95% CI: 0.......88-0.91) and sensitivity (0.97, 95% CI: 0.87-1.0) of the Onclarity assay were shown to be non-inferior to the reference assay (specificity 0.90, 95% CI: 0.88-0.92, sensitivity 0.98, 95% CI: 0.91-1.0). The intra-laboratory reproducibility of Onclarity was 97% with a lower confidence bound of 96% (kappa value: 0...

  16. Forecasting the Number of Soil Samples Required to Reduce Remediation Cost Uncertainty

    OpenAIRE

    Demougeot-Renard, Hélène; de Fouquet, Chantal; Renard, Philippe

    2008-01-01

    Sampling scheme design is an important step in the management of polluted sites. It largely controls the accuracy of remediation cost estimates. In practice, however, sampling is seldom designed to comply with a given level of remediation cost uncertainty. In this paper, we present a new technique that allows one to estimate of the number of samples that should be taken at a given stage of investigation to reach a forecasted level of accuracy. The uncertainty is expressed both in terms of vol...

  17. Determination of ferrous and total iron in refractory spinels

    Energy Technology Data Exchange (ETDEWEB)

    Amonette, J.E. [Physical Sciences Division, Pacific Northwest National Laboratory, Richland, WA 99352 (United States); Matyáš, J. [Material Science Department, Pacific Northwest National Laboratory, Richland, WA 99352 (United States)

    2016-03-03

    Accurate and precise determination of the redox state of iron (Fe) in spinels presents a significant challenge due to their refractory nature. The resultant extreme conditions needed to obtain complete dissolution generally oxidize some of the Fe(II) initially present and thus prevent the use of colorimetric methods for Fe(II) measurements. To overcome this challenge we developed a hybrid oxidimetric/colorimetric approach, using Ag(I) as the oxidimetric reagent for determination of Fe(II) and 1,10-phenanthroline as the colorimetric reagent for determination of total Fe. This approach, which allows determination of Fe(II) and total Fe on the same sample, was tested on a series of four geochemical reference materials and then applied to the analysis of Fe(Ni) spinel crystals isolated from simulated high-level-waste (HLW) glass and of several reagent magnetites. Results for the reference materials were in excellent agreement with recommended values, with the exception of USGS BIR-1, for which higher Fe(II) values and lower total Fe values were obtained. The Fe(Ni) spinels showed Fe(II) values at the detection limit (ca. 0.03 wt% Fe) and total Fe values higher than obtained by ICP-AES analysis after decomposition by lithium metaborate/tetraborate fusion. For the magnetite samples, total Fe values were in agreement with reference results, but a wide range in Fe(II) values was obtained indicating various degrees of conversion to maghemite. Formal comparisons of accuracy and precision were made with 13 existing methods. Accuracy for Fe(II) and total Fe was at or near the top of the group. Precision varied with the parameter used to measure it but was generally in the middle to upper part of the group for Fe(II) while that for total Fe ranged from the bottom of the group to near the top. - Highlights: • Refractory samples, such as spinels, are the most difficult for Fe redox analysis. • Oxidimetric(Ag{sup +})/colorimetric (phen) method allows analysis of a single

  18. Hot sample archiving. Revision 3

    International Nuclear Information System (INIS)

    McVey, C.B.

    1995-01-01

    This Engineering Study revision evaluated the alternatives to provide tank waste characterization analytical samples for a time period as recommended by the Tank Waste Remediation Systems Program. The recommendation of storing 40 ml segment samples for a period of approximately 18 months (6 months past the approval date of the Tank Characterization Report) and then composite the core segment material in 125 ml containers for a period of five years. The study considers storage at 222-S facility. It was determined that the critical storage problem was in the hot cell area. The 40 ml sample container has enough material for approximately 3 times the required amount for a complete laboratory re-analysis. The final result is that 222-S can meet the sample archive storage requirements. During the 100% capture rate the capacity is exceeded in the hot cell area, but quick, inexpensive options are available to meet the requirements

  19. Influence of the ischaemic tourniquet in antibiotic prophylaxis in total knee replacement.

    Science.gov (United States)

    Prats, Laura; Valls, Joan; Ros, Joaquim; Jover, Alfredo; Pérez-Villar, Ferran; Fernández-Martínez, José Juan

    2015-01-01

    There is level iv evidence that the preoperative administration of antibiotics helps in the prevention of prosthetic infection. There is controversy on whether the ischemia applied during surgery may affect the minimum inhibitory concentration of the antibiotic in the peri-prosthetic tissues. The aim of this study is to review this phenomenon through the determination of antibiotic concentration in the synovial tissue. A prospective observational clinical study was conducted on 32 patients undergoing total knee replacement. Cefonicid 2g was administered as prophylaxis, with a tourniquet used for all patients. The antibiotic concentration was quantified by high performance liquid chromatography in samples of synovial tissue collected at the beginning and at the end of the intervention. The mean concentration of antibiotic was 23.16 μg/g (95% CI 19.19 to 27.13) in the samples at the beginning of the intervention and 15.45 μg/g (95% CI 13.20 to 17.69) in the final samples, being higher than the minimum inhibitory concentration of cefonicid, set at 8 μg/g. These results were statistically significant for both concentrations (P<.00001). The antibiotic concentration throughout the standard total knee prosthesis surgery performed with tourniquet gradually decreases throughout the intervention. The concentration determined at the end of the intervention was higher than the minimum inhibitory concentration required for the antibiotic studied. In conclusion, the use of a tourniquet does not increase the risk of infection. Copyright © 2014 SECOT. Published by Elsevier Espana. All rights reserved.

  20. Rheology and TIC/TOC results of ORNL tank samples

    International Nuclear Information System (INIS)

    Pareizs, J. M.; Hansen, E. K.

    2013-01-01

    The Savannah River National Laboratory (SRNL)) was requested by Oak Ridge National Laboratory (ORNL) to perform total inorganic carbon (TIC), total organic carbon (TOC), and rheological measurements for several Oak Ridge tank samples. As received slurry samples were diluted and submitted to SRNL-Analytical for TIC and TOC analyses. Settled solids yield stress (also known as settled shear strength) of the as received settled sludge samples were determined using the vane method and these measurements were obtained 24 hours after the samples were allowed to settled undisturbed. Rheological or flow properties (Bingham Plastic viscosity and Bingham Plastic yield stress) were determined from flow curves of the homogenized or well mixed samples. Other targeted total suspended solids (TSS) concentrations samples were also analyzed for flow properties and these samples were obtained by diluting the as-received sample with de-ionized (DI) water

  1. Determination of total cyanide in Hanford Site high-level wastes

    Energy Technology Data Exchange (ETDEWEB)

    Winters, W.I. [Westinghouse Hanford Co., Richland, WA (United States); Pool, K.H. [Pacific Northwest Lab., Richland, WA (United States)

    1994-05-01

    Nickel ferrocyanide compounds (Na{sub 2-x}Cs{sub x}NiFe (CN){sub 6}) were produced in a scavenging process to remove {sup 137}Cs from Hanford Site single-shell tank waste supernates. Methods for determining total cyanide in Hanford Site high-level wastes are needed for the evaluation of potential exothermic reactions between cyanide and oxidizers such as nitrate and for safe storage, processing, and management of the wastes in compliance with regulatory requirements. Hanford Site laboratory experience in determining cyanide in high-level wastes is summarized. Modifications were made to standard cyanide methods to permit improved handling of high-level waste samples and to eliminate interferences found in Hanford Site waste matrices. Interferences and associated procedure modifications caused by high nitrates/nitrite concentrations, insoluble nickel ferrocyanides, and organic complexants are described.

  2. Determination of total cyanide in Hanford Site high-level wastes

    International Nuclear Information System (INIS)

    Winters, W.I.; Pool, K.H.

    1994-05-01

    Nickel ferrocyanide compounds (Na 2-x Cs x NiFe (CN) 6 ) were produced in a scavenging process to remove 137 Cs from Hanford Site single-shell tank waste supernates. Methods for determining total cyanide in Hanford Site high-level wastes are needed for the evaluation of potential exothermic reactions between cyanide and oxidizers such as nitrate and for safe storage, processing, and management of the wastes in compliance with regulatory requirements. Hanford Site laboratory experience in determining cyanide in high-level wastes is summarized. Modifications were made to standard cyanide methods to permit improved handling of high-level waste samples and to eliminate interferences found in Hanford Site waste matrices. Interferences and associated procedure modifications caused by high nitrates/nitrite concentrations, insoluble nickel ferrocyanides, and organic complexants are described

  3. Determination of total, and bound Se in sera by INAA

    International Nuclear Information System (INIS)

    Spate, V.L.; Mason, M.M.; Reams, C.L.; Baskett, C.K.; Morris, J.S.; Mills, D.S.

    1994-01-01

    The comparison between the total selenium in serum ('total Se') with that which is apparently bound to high molecular weight (> 12.000 D) species, presumably proteins ('bound Se') was reported. Nine hundred seventy seven (977) serum samples arising out of a population-based epidemiological study were prepared in duplicate for the determination of 'total Se' by pipeting directly into irradiation vials; and separate duplicate aliquots were dialyzed against DI water for the determination of 'bound Se'. All samples were analyzed by neutron activation analysis via 77m Se (17.4s) A small dialyzable Se component (∼ 6%) ('free Se'), defined as the difference between the 'total Se' minus the 'bound Se', was identified. (author) 2 refs.; 3 figs.; 5 tabs

  4. Chemometrics methods for the investigation of methylmercury and total mercury contamination in mollusks samples collected from coastal sites along the Chinese Bohai Sea

    International Nuclear Information System (INIS)

    Wang Yawei; Liang Lina; Shi Jianbo; Jiang Guibin

    2005-01-01

    The development and application of chemometrics methods, principal component analysis (PCA), cluster analysis and correlation analysis for the determination of methylmercury (MeHg) and total mercury (HgT) in gastropod and bivalve species collected from eight coastal sites along the Chinese Bohai Sea are described. HgT is directly determined by atomic fluorescence spectrometry (AFS), while MeHg is measured by a laboratory established high performance liquid chromatography-atomic fluorescence spectrometry system (HPLC-AFS). One-way ANOVA and cluster analysis indicated that the bioaccumulation of Rap to accumulate Hg was significantly (P<0.05) different from other mollusks. Correlation analysis shows that there is linear relationship between MeHg and HgT in mollusks samples collected from coastal sites along the Chinese Bohai Sea, while in mollusks samples collected from Hongqiao market in Beijing City, there is not any linear relationship. - Rapana venosa might be used as a potential biomonitor for Hg pollution in the Bohai Sea, China

  5. Comparative Analysis of Clinical Samples Showing Weak Serum Reaction on AutoVue System Causing ABO Blood Typing Discrepancies

    OpenAIRE

    Jo, Su Yeon; Lee, Ju Mi; Kim, Hye Lim; Sin, Kyeong Hwa; Lee, Hyeon Ji; Chang, Chulhun Ludgerus; Kim, Hyung-Hoi

    2016-01-01

    Background ABO blood typing in pre-transfusion testing is a major component of the high workload in blood banks that therefore requires automation. We often experienced discrepant results from an automated system, especially weak serum reactions. We evaluated the discrepant results by the reference manual method to confirm ABO blood typing. Methods In total, 13,113 blood samples were tested with the AutoVue system; all samples were run in parallel with the reference manual method according to...

  6. A simple method for plasma total vitamin C analysis suitable for routine clinical laboratory use.

    Science.gov (United States)

    Robitaille, Line; Hoffer, L John

    2016-04-21

    In-hospital hypovitaminosis C is highly prevalent but almost completely unrecognized. Medical awareness of this potentially important disorder is hindered by the inability of most hospital laboratories to determine plasma vitamin C concentrations. The availability of a simple, reliable method for analyzing plasma vitamin C could increase opportunities for routine plasma vitamin C analysis in clinical medicine. Plasma vitamin C can be analyzed by high performance liquid chromatography (HPLC) with electrochemical (EC) or ultraviolet (UV) light detection. We modified existing UV-HPLC methods for plasma total vitamin C analysis (the sum of ascorbic and dehydroascorbic acid) to develop a simple, constant-low-pH sample reduction procedure followed by isocratic reverse-phase HPLC separation using a purely aqueous low-pH non-buffered mobile phase. Although EC-HPLC is widely recommended over UV-HPLC for plasma total vitamin C analysis, the two methods have never been directly compared. We formally compared the simplified UV-HPLC method with EC-HPLC in 80 consecutive clinical samples. The simplified UV-HPLC method was less expensive, easier to set up, required fewer reagents and no pH adjustments, and demonstrated greater sample stability than many existing methods for plasma vitamin C analysis. When compared with the gold-standard EC-HPLC method in 80 consecutive clinical samples exhibiting a wide range of plasma vitamin C concentrations, it performed equivalently. The easy set up, simplicity and sensitivity of the plasma vitamin C analysis method described here could make it practical in a normally equipped hospital laboratory. Unlike any prior UV-HPLC method for plasma total vitamin C analysis, it was rigorously compared with the gold-standard EC-HPLC method and performed equivalently. Adoption of this method could increase the availability of plasma vitamin C analysis in clinical medicine.

  7. Indications and the requirements for single-use medical gloves

    Science.gov (United States)

    Kramer, Axel; Assadian, Ojan

    2016-01-01

    Aim: While the requirements for single-use gloves for staff protection are clearly defined, the conventional medical differentiation between “sterile surgical gloves” used during surgical procedures and “single-use medical gloves” used in non-sterile medical areas does not adequately define the different requirements in these two areas of use. Sterilization of single-use medical gloves is not performed if sterility is not required; thus, another terminology must be found to identify the safety quality of non-sterile single-use medical gloves. Therefore, the labeling of such gloves should reflect this situation, by introducing the term “pathogen-free” single-use glove. The hygienic safety of such a glove would be attainable by ensuring aseptic manufacturing conditions during manufacturing and control of pathogen load of batch controls after fabrication. Proposed recommendation: Because single-use gloves employed in non-sterile areas come into contact not only with intact skin but also with mucous membranes, no potential pathogens should be detectable in 100 mL of rinse sample. In order to declare such gloves as pathogen-free we suggest absence of the indicator species S. aureus and E. coli. In addition, the total CFU count should be evaluated, since a high load indicates lack of optimal hygiene during the manufacturing process. Based on the requirements for potable water and findings obtained from investigations of the bacterial load of such gloves after manufacturing, the here suggested limit for the total bacterial count of glove seems realistic. PMID:26816673

  8. Credit in Acceptance Sampling on Attributes

    NARCIS (Netherlands)

    Klaassen, Chris A.J.

    2000-01-01

    Credit is introduced in acceptance sampling on attributes and a Credit Based Acceptance sampling system is developed that is very easy to apply in practice.The credit of a producer is defined as the total number of items accepted since the last rejection.In our sampling system the sample size for a

  9. Deltamethrin in sediment samples of the Okavango Delta, Botswana ...

    African Journals Online (AJOL)

    Analysis of samples for organic matter content showed percentage total organic carbon (% TOC) ranging between 0.19% and 8.21%, with samples collected from the pool having the highest total organic carbon. The concentrations of deltamethrin residues and the % TOC in sediment samples showed a similar trend with ...

  10. Analysis of Serum Total and Free PSA Using Immunoaffinity Depletion Coupled to SRM: Correlation with Clinical Immunoassay Tests

    Science.gov (United States)

    Liu, Tao; Hossain, Mahmud; Schepmoes, Athena A.; Fillmore, Thomas L.; Sokoll, Lori J.; Kronewitter, Scott R.; Izmirlian, Grant; Shi, Tujin; Qian, Wei-Jun; Leach, Robin J.; Thompson, Ian M.; Chan, Daniel W.; Smith, Richard D.; Kagan, Jacob; Srivastava, Sudhir; Rodland, Karin D.; Camp, David G.

    2012-01-01

    Recently, selected reaction monitoring mass spectrometry (SRM-MS) has been more frequently applied to measure low abundance biomarker candidates in tissues and biofluids, owing to its high sensitivity and specificity, simplicity of assay configuration, and exceptional multiplexing capability. In this study, we report for the first time the development of immunoaffinity depletion-based workflows and SRM-MS assays that enable sensitive and accurate quantification of total and free prostate-specific antigen (PSA) in serum without the requirement for specific PSA antibodies. Low ng/mL level detection of both total and free PSA was consistently achieved in both PSA-spiked female serum samples and actual patient serum samples. Moreover, comparison of the results obtained when SRM PSA assays and conventional immunoassays were applied to the same samples showed good correlation in several independent clinical serum sample sets. These results demonstrate that the workflows and SRM assays developed here provide an attractive alternative for reliably measuring candidate biomarkers in human blood, without the need to develop affinity reagents. Furthermore, the simultaneous measurement of multiple biomarkers, including the free and bound forms of PSA, can be performed in a single multiplexed analysis using high-resolution liquid chromatographic separation coupled with SRM-MS. PMID:22846433

  11. METHOD 415.3 - MEASUREMENT OF TOTAL ORGANIC ...

    Science.gov (United States)

    2.0 SUMMARY OF METHOD2.1 In both TOC and DOC determinations, organic carbon in the water sample is oxidized to form carbon dioxide (CO2), which is then measured by a detection system. There are two different approaches for the oxidation of organic carbon in water samples to carbon dioxide gas: (a) combustion in an oxidizing gas and (b) UV promoted or heat catalized chemical oxidation with a persulfate solution. Carbon dioxide, which is released from the oxidized sample, is detected by a conductivity detector or by a nondispersive infrared (NDIR) detector. Instruments using any combination of the above technologies may be used in this method.2.2. Setteable solids and floating matter may cause plugging of valves, tubing, and the injection needle port. The TOC procedure allows the removal of settleable solids and floating matter. The suspended matter is considered part of the sample. The resulting water sample is then considered a close approximation of the original whole water sample for the purpose of TOC measurement.2.3. The DOC procedure requires that the sample be passed through a 0.45 um filter prior to analysis.2.4. The TOC and DOC procedures require that all inorganic carbon be removed from the sample before the sample is analyzed for organic carbon content. If the inorganic carbon (IC) is not completely removed, significant error will occur. The inorganic carbon interference is removed by converting the mineralized IC to CO2 by acidification and

  12. Total synthesis of five lipoteichoic acids of Clostridium difficile

    DEFF Research Database (Denmark)

    Hogendorf, Wouter Frederik Johan; Gisch, Nicolas; Schwudke, Dominik

    2014-01-01

    The emergence of hypervirulent resistant strains have made Clostridium difficile a notorious nosocomial pathogen and has resulted in a renewed interest in preventive strategies, such as vaccines based on (synthetic) cell wall antigens. Recently, the structure of the lipoteichoic acid (LTA......) of this species has been elucidated. Additionally, this LTA was found to induce the formation of protective antibodies against C. difficile in rabbits and mice. The LTA from C. difficile is isolated as a microheterogenous mixture, differing in size and composition, impeding any structure-activity relationship...... studies. To ensure reliable biological results, pure and well-defined synthetic samples are required. In this work the total synthesis of LTAs from C. difficile with defined chain length is described and the initial biological results are presented....

  13. Development of SYVAC sampling techniques

    International Nuclear Information System (INIS)

    Prust, J.O.; Dalrymple, G.J.

    1985-04-01

    This report describes the requirements of a sampling scheme for use with the SYVAC radiological assessment model. The constraints on the number of samples that may be taken is considered. The conclusions from earlier studies using the deterministic generator sampling scheme are summarised. The method of Importance Sampling and a High Dose algorithm, which are designed to preferentially sample in the high dose region of the parameter space, are reviewed in the light of experience gained from earlier studies and the requirements of a site assessment and sensitivity analyses. In addition the use of an alternative numerical integration method for estimating risk is discussed. It is recommended that the method of Importance Sampling is developed and tested for use with SYVAC. An alternative numerical integration method is not recommended for investigation at this stage but should be the subject of future work. (author)

  14. Time optimization of 90Sr measurements: Sequential measurement of multiple samples during ingrowth of 90Y

    International Nuclear Information System (INIS)

    Holmgren, Stina; Tovedal, Annika; Björnham, Oscar; Ramebäck, Henrik

    2016-01-01

    The aim of this paper is to contribute to a more rapid determination of a series of samples containing 90 Sr by making the Cherenkov measurement of the daughter nuclide 90 Y more time efficient. There are many instances when an optimization of the measurement method might be favorable, such as; situations requiring rapid results in order to make urgent decisions or, on the other hand, to maximize the throughput of samples in a limited available time span. In order to minimize the total analysis time, a mathematical model was developed which calculates the time of ingrowth as well as individual measurement times for n samples in a series. This work is focused on the measurement of 90 Y during ingrowth, after an initial chemical separation of strontium, in which it is assumed that no other radioactive strontium isotopes are present. By using a fixed minimum detectable activity (MDA) and iterating the measurement time for each consecutive sample the total analysis time will be less, compared to using the same measurement time for all samples. It was found that by optimization, the total analysis time for 10 samples can be decreased greatly, from 21 h to 6.5 h, when assuming a MDA of 1 Bq/L and at a background count rate of approximately 0.8 cpm. - Highlights: • An approach roughly a factor of three more efficient than an un-optimized method. • The optimization gives a more efficient use of instrument time. • The efficiency increase ranges from a factor of three to 10, for 10 to 40 samples.

  15. Phase 1 sampling and analysis plan for the 304 Concretion Facility closure activities

    International Nuclear Information System (INIS)

    Adler, J.G.

    1994-01-01

    This document provides guidance for the initial (Phase 1) sampling and analysis activities associated with the proposed Resource Conservation and Recovery Act of 1976 (RCRA) clean closure of the 304 Concretion Facility. Over its service life, the 304 Concretion Facility housed the pilot plants associated with cladding uranium cores, was used to store engineering equipment and product chemicals, was used to treat low-level radioactive mixed waste, recyclable scrap uranium generated during nuclear fuel fabrication, and uranium-titanium alloy chips, and was used for the repackaging of spent halogenated solvents from the nuclear fuels manufacturing process. The strategy for clean closure of the 304 Concretion Facility is to decontaminate, sample (Phase 1 sampling), and evaluate results. If the evaluation indicates that a limited area requires additional decontamination for clean closure, the limited area will be decontaminated, resampled (Phase 2 sampling), and the result evaluated. If the evaluation indicates that the constituents of concern are below action levels, the facility will be clean closed. Or, if the evaluation indicates that the constituents of concern are present above action levels, the condition of the facility will be evaluated and appropriate action taken. There are a total of 37 sampling locations comprising 12 concrete core, 1 concrete chip, 9 soil, 11 wipe, and 4 asphalt core sampling locations. Analysis for inorganics and volatile organics will be performed on the concrete core and soil samples. Separate concrete core samples will be required for the inorganic and volatile organic analysis (VOA). Analysis for inorganics only will be performed on the concrete chip, wipe, and asphalt samples

  16. Should All Patients Be Included in Alternative Payment Models for Primary Total Hip Arthroplasty and Total Knee Arthroplasty?

    Science.gov (United States)

    Rozell, Joshua C; Courtney, Paul M; Dattilo, Jonathan R; Wu, Chia H; Lee, Gwo-Chin

    2016-09-01

    Alternative payment models in total joint replacement incentivize cost effective health care delivery and reward reductions in length of stay (LOS), complications, and readmissions. If not adjusted for patient comorbidities, they may encourage restrictive access to health care. We prospectively evaluated 802 consecutive primary total hip arthroplasty and total knee arthroplasty patients evaluating comorbidities associated with increased LOS and readmissions. During this 9-month period, 115 patients (14.3%) required hospitalization >3 days and 16 (1.99%) were readmitted within 90 days. Univariate analysis demonstrated that preoperative narcotic use, heart failure, stroke, chronic kidney disease (CKD), chronic obstructive pulmonary disease (COPD), and liver disease were more likely to require hospitalization >3 days. In multivariate analysis, CKD and COPD were independent risk factors for LOS >3 days. A Charlson comorbidity index >5 points was associated with increased LOS and readmissions. Patients with CKD, COPD, and Charlson comorbidity index >5 points should not be included in alternative payment model for THA and TKA. Copyright © 2016 Elsevier Inc. All rights reserved.

  17. A method of language sampling

    DEFF Research Database (Denmark)

    Rijkhoff, Jan; Bakker, Dik; Hengeveld, Kees

    1993-01-01

    In recent years more attention is paid to the quality of language samples in typological work. Without an adequate sampling strategy, samples may suffer from various kinds of bias. In this article we propose a sampling method in which the genetic criterion is taken as the most important: samples...... to determine how many languages from each phylum should be selected, given any required sample size....

  18. Analysis of H2O in silicate glass using attenuated total reflectance (ATR) micro-FTIR spectroscopy

    Science.gov (United States)

    Lowenstern, Jacob B.; Pitcher, Bradley W.

    2013-01-01

    We present a calibration for attenuated total reflectance (ATR) micro-FTIR for analysis of H2O in hydrous glass. A Ge ATR accessory was used to measure evanescent wave absorption by H2O within hydrous rhyolite and other standards. Absorbance at 3450 cm−1 (representing total H2O or H2Ot) and 1630 cm−1 (molecular H2O or H2Om) showed high correlation with measured H2O in the glasses as determined by transmission FTIR spectroscopy and manometry. For rhyolite, wt%H2O=245(±9)×A3450-0.22(±0.03) and wt%H2Om=235(±11)×A1630-0.20(±0.03) where A3450 and A1630 represent the ATR absorption at the relevant infrared wavelengths. The calibration permits determination of volatiles in singly polished glass samples with spot size down to ~5 μm (for H2O-rich samples) and detection limits of ~0.1 wt% H2O. Basaltic, basaltic andesite and dacitic glasses of known H2O concentrations fall along a density-adjusted calibration, indicating that ATR is relatively insensitive to glass composition, at least for calc-alkaline glasses. The following equation allows quantification of H2O in silicate glasses that range in composition from basalt to rhyolite: wt%H2O=(ω×A3450/ρ)+b where ω = 550 ± 21, b = −0.19 ± 0.03, ρ = density, in g/cm3, and A3450 is the ATR absorbance at 3450 cm−1. The ATR micro-FTIR technique is less sensitive than transmission FTIR, but requires only a singly polished sample for quantitative results, thus minimizing time for sample preparation. Compared with specular reflectance, it is more sensitive and better suited for imaging of H2O variations in heterogeneous samples such as melt inclusions. One drawback is that the technique can damage fragile samples and we therefore recommend mounting of unknowns in epoxy prior to polishing. Our calibration should hold for any Ge ATR crystals with the same incident angle (31°). Use of a different crystal type or geometry would require measurement of several H2O-bearing standards to provide a crystal

  19. Soil Sampling to Demonstrate Compliance with Department of Energy Radiological Clearance Requirements for the ALE Unit of the Hanford Reach National Monument

    Energy Technology Data Exchange (ETDEWEB)

    Fritz, Brad G.; Dirkes, Roger L.; Napier, Bruce A.

    2007-04-01

    The Hanford Reach National Monument consists of several units, one of which is the Fitzner/Eberhardt Arid Lands Ecology Reserve (ALE) Unit. This unit is approximately 311 km2 of shrub-steppe habitat located to the south and west of Highway 240. To fulfill internal U. S. Department of Energy (DOE) requirements prior to any radiological clearance of land, DOE must evaluate the potential for residual radioactive contamination on this land and determine compliance with the requirements of DOE Order 5400.5. Historical soil monitoring conducted on ALE indicated soil concentrations of radionuclides were well below the Authorized Limits. However, the historical sampling was done at a limited number of sampling locations. Therefore, additional soil sampling was conducted to determine if the concentrations of radionuclides in soil on the ALE Unit were below the Authorized Limits. This report contains the results of 50 additional soil samples. The 50 soil samples collected from the ALE Unit all had concentrations of radionuclides far below the Authorized Limits. The average concentrations for all detectable radionuclides were less than the estimated Hanford Site background. Furthermore, the maximum observed soil concentrations for the radionuclides included in the Authorized Limits would result in a potential annual dose of 0.14 mrem assuming the most probable use scenario, a recreational visitor. This potential dose is well below the DOE 100-mrem per year dose limit for a member of the public. Spatial analysis of the results indicated no observable statistically significant differences between radionuclide concentrations across the ALE Unit. Furthermore, the results of the biota dose assessment screen, which used the ResRad Biota code, indicated that the concentrations of radionuclides in ALE Unit soil pose no significant health risk to biota.

  20. Infrared biospectroscopy for a fast qualitative evaluation of sample preparation in metabolomics.

    Science.gov (United States)

    Kuligowski, Julia; Pérez-Guaita, David; Escobar, Javier; Lliso, Isabel; de la Guardia, Miguel; Lendl, Bernhard; Vento, Máximo; Quintás, Guillermo

    2014-09-01

    Liquid chromatography-mass spectrometry (LC-MS) has been increasingly used in biomedicine to study the dynamic metabolomic responses of biological systems under different physiological or pathological conditions. To obtain an integrated snapshot of the system, metabolomic methods in biomedicine typically analyze biofluids (e.g. plasma) that require clean-up before being injected into LC-MS systems. However, high resolution LC-MS is costly in terms of resources required for sample and data analysis and care must be taken to prevent chemical (e.g. ion suppression) or statistical artifacts. Because of that, the effect of sample preparation on the metabolomic profile during metabolomic method development is often overlooked. This work combines an Attenuated Total Reflectance-Fourier transform infrared (ATR-FTIR) and a multivariate exploratory data analysis for a cost-effective qualitative evaluation of major changes in sample composition during sample preparation. ATR-FTIR and LC-time of flight mass spectrometry (TOFMS) data from the analysis of a set of plasma samples precipitated using acetonitrile, methanol and acetone performed in parallel were used as a model example. Biochemical information obtained from the analysis of the ATR-FTIR and LC-TOFMS data was thoroughly compared to evaluate the strengths and shortcomings of FTIR biospectroscopy for assessing sample preparation in metabolomics studies. Results obtained show the feasibility of ATR-FTIR for the evaluation of major trends in the plasma composition changes among different sample pretreatments, providing information in terms of e.g., amino acids, proteins, lipids and carbohydrates overall contents comparable to those found by LC-TOFMS. Copyright © 2014 Elsevier B.V. All rights reserved.

  1. Phenol-Sulfuric Acid Method for Total Carbohydrates

    Science.gov (United States)

    Nielsen, S. Suzanne

    The phenol-sulfuric acid method is a simple and rapid colorimetric method to determine total carbohydrates in a sample. The method detects virtually all classes of carbohydrates, including mono-, di-, oligo-, and polysaccharides. Although the method detects almost all carbohydrates, the absorptivity of the different carbohydrates varies. Thus, unless a sample is known to contain only one carbohydrate, the results must be expressed arbitrarily in terms of one carbohydrate.

  2. The Evaluation of Teachers' Job Performance Based on Total Quality Management (TQM)

    Science.gov (United States)

    Shahmohammadi, Nayereh

    2017-01-01

    This study aimed to evaluate teachers' job performance based on total quality management (TQM) model. This was a descriptive survey study. The target population consisted of all primary school teachers in Karaj (N = 2917). Using Cochran formula and simple random sampling, 340 participants were selected as sample. A total quality management…

  3. Combining Electrochemical Sensors with Miniaturized Sample Preparation for Rapid Detection in Clinical Samples

    Science.gov (United States)

    Bunyakul, Natinan; Baeumner, Antje J.

    2015-01-01

    Clinical analyses benefit world-wide from rapid and reliable diagnostics tests. New tests are sought with greatest demand not only for new analytes, but also to reduce costs, complexity and lengthy analysis times of current techniques. Among the myriad of possibilities available today to develop new test systems, amperometric biosensors are prominent players—best represented by the ubiquitous amperometric-based glucose sensors. Electrochemical approaches in general require little and often enough only simple hardware components, are rugged and yet provide low limits of detection. They thus offer many of the desirable attributes for point-of-care/point-of-need tests. This review focuses on investigating the important integration of sample preparation with (primarily electrochemical) biosensors. Sample clean up requirements, miniaturized sample preparation strategies, and their potential integration with sensors will be discussed, focusing on clinical sample analyses. PMID:25558994

  4. Whole genome transcript profiling from fingerstick blood samples: a comparison and feasibility study

    Directory of Open Access Journals (Sweden)

    Williams Adam R

    2009-12-01

    Full Text Available Abstract Background Whole genome gene expression profiling has revolutionized research in the past decade especially with the advent of microarrays. Recently, there have been significant improvements in whole blood RNA isolation techniques which, through stabilization of RNA at the time of sample collection, avoid bias and artifacts introduced during sample handling. Despite these improvements, current human whole blood RNA stabilization/isolation kits are limited by the requirement of a venous blood sample of at least 2.5 mL. While fingerstick blood collection has been used for many different assays, there has yet to be a kit developed to isolate high quality RNA for use in gene expression studies from such small human samples. The clinical and field testing advantages of obtaining reliable and reproducible gene expression data from a fingerstick are many; it is less invasive, time saving, more mobile, and eliminates the need of a trained phlebotomist. Furthermore, this method could also be employed in small animal studies, i.e. mice, where larger sample collections often require sacrificing the animal. In this study, we offer a rapid and simple method to extract sufficient amounts of high quality total RNA from approximately 70 μl of whole blood collected via a fingerstick using a modified protocol of the commercially available Qiagen PAXgene RNA Blood Kit. Results From two sets of fingerstick collections, about 70 uL whole blood collected via finger lancet and capillary tube, we recovered an average of 252.6 ng total RNA with an average RIN of 9.3. The post-amplification yields for 50 ng of total RNA averaged at 7.0 ug cDNA. The cDNA hybridized to Affymetrix HG-U133 Plus 2.0 GeneChips had an average % Present call of 52.5%. Both fingerstick collections were highly correlated with r2 values ranging from 0.94 to 0.97. Similarly both fingerstick collections were highly correlated to the venous collection with r2 values ranging from 0.88 to 0

  5. Study of exhaled breath condensate sample preparation for metabolomics analysis by LC-MS/MS in high resolution mode.

    Science.gov (United States)

    Fernández-Peralbo, M A; Calderón Santiago, M; Priego-Capote, F; Luque de Castro, M D

    2015-11-01

    Metabolomic analysis of exhaled breath condensate (EBC) requires an unavoidable sample preparation step because of the low concentration of its components, and potential cleanup for possible interferents. Sample preparation based on protein precipitation (PP), solid-phase extraction (SPE) by hydrophilic and lipophilic sorbents or lyophilization has demonstrated that the analytical sample from the last is largely the best because lyophilization allows reconstitution in a volume as small as required (preconcentration factors up to 80-times with respect to the original sample), thus doubling the number of detected compounds as compared with the other alternatives (47 versus 25). In addition, PP and/or SPE cleanup are unnecessary as no effect from the EBC components removed by these steps appears in the chromatograms. The total 49 EBC compounds tentatively identified and confirmed by MS/MS in this research include amino acids, fatty acids, fatty amides, fatty aldehydes, sphingoid bases, oxoanionic compounds, imidazoles, hydroxy acids and aliphatic acyclic acids. Copyright © 2015 Elsevier B.V. All rights reserved.

  6. TOTAL FINA ELF. Annual report 2002

    International Nuclear Information System (INIS)

    2003-01-01

    This document is the annual report 2002 of Total-Fina-Elf society, great company on the hydrocarbons market. According to the company objective (set the standard not only with the financial performance, but also with stringent requirements in terms of social and environmental responsibility), it presents the Chairman message, the corporate governance, the social and environmental responsibility, the future of energy, the human resources policy, the investor relations, the overview of Total-Fina-Elf fiscal year with financial information and 2002 industrial events. (A.L.B.)

  7. (238)U and total radioactivity in drinking waters in Van province, Turkey.

    Science.gov (United States)

    Selçuk Zorer, Özlem; Dağ, Beşir

    2014-06-01

    As part of the national survey to evaluate natural radioactivity in the environment, concentration levels of total radioactivity and natural uranium have been analysed in drinking water samples. A survey to study natural radioactivity in drinking waters was carried out in the Van province, East Turkey. Twenty-three samples of drinking water were collected in the Van province and analysed for total α, total β and (238)U activity. The total α and total β activities were counted by using the α/β counter of the multi-detector low background system (PIC MPC-9604), and the (238)U concentrations were determined by inductively coupled plasma-mass spectrometry (Thermo Scientific Element 2). The samples were categorised according to origin: tap, spring or mineral supply. The activity concentrations for total α were found to range from 0.002 to 0.030 Bq L(-1) and for total β from 0.023 to 1.351 Bq L(-1). Uranium concentrations ranging from 0.562 to 14.710 μg L(-1) were observed in drinking waters. Following the World Health Organisation rules, all investigated waters can be used as drinking water.

  8. A systematic random sampling scheme optimized to detect the proportion of rare synapses in the neuropil.

    Science.gov (United States)

    da Costa, Nuno Maçarico; Hepp, Klaus; Martin, Kevan A C

    2009-05-30

    Synapses can only be morphologically identified by electron microscopy and this is often a very labor-intensive and time-consuming task. When quantitative estimates are required for pathways that contribute a small proportion of synapses to the neuropil, the problems of accurate sampling are particularly severe and the total time required may become prohibitive. Here we present a sampling method devised to count the percentage of rarely occurring synapses in the neuropil using a large sample (approximately 1000 sampling sites), with the strong constraint of doing it in reasonable time. The strategy, which uses the unbiased physical disector technique, resembles that used in particle physics to detect rare events. We validated our method in the primary visual cortex of the cat, where we used biotinylated dextran amine to label thalamic afferents and measured the density of their synapses using the physical disector method. Our results show that we could obtain accurate counts of the labeled synapses, even when they represented only 0.2% of all the synapses in the neuropil.

  9. Small-angle X-ray scattering tensor tomography: model of the three-dimensional reciprocal-space map, reconstruction algorithm and angular sampling requirements.

    Science.gov (United States)

    Liebi, Marianne; Georgiadis, Marios; Kohlbrecher, Joachim; Holler, Mirko; Raabe, Jörg; Usov, Ivan; Menzel, Andreas; Schneider, Philipp; Bunk, Oliver; Guizar-Sicairos, Manuel

    2018-01-01

    Small-angle X-ray scattering tensor tomography, which allows reconstruction of the local three-dimensional reciprocal-space map within a three-dimensional sample as introduced by Liebi et al. [Nature (2015), 527, 349-352], is described in more detail with regard to the mathematical framework and the optimization algorithm. For the case of trabecular bone samples from vertebrae it is shown that the model of the three-dimensional reciprocal-space map using spherical harmonics can adequately describe the measured data. The method enables the determination of nanostructure orientation and degree of orientation as demonstrated previously in a single momentum transfer q range. This article presents a reconstruction of the complete reciprocal-space map for the case of bone over extended ranges of q. In addition, it is shown that uniform angular sampling and advanced regularization strategies help to reduce the amount of data required.

  10. Sampling technologies and air pollution control devices for gaseous and particulate arsenic: a review

    International Nuclear Information System (INIS)

    Helsen, Lieve

    2005-01-01

    Direct measurement of arsenic release requires a good sampling and analysis procedure in order to capture and detect the total amount of metals emitted. The literature is extensively reviewed in order to evaluate the efficiency of full field-scale and laboratory scale techniques for capturing particulate and gaseous emissions of arsenic from the thermo-chemical treatment of different sources of arsenic. Furthermore, trace arsenic concentrations in ambient air, national standard sampling methods and arsenic analysis methods are considered. Besides sampling techniques, the use of sorbents is also reviewed with respect to both approaches (1) to prevent the metals from exiting with the flue gas and (2) to react or combine with the metals in order to be collected in air pollution control systems. The most important conclusion is that submicron arsenic fumes are difficult to control in conventional air pollution control devices. Complete capture of the arsenic species requires a combination of particle control and vapour control devices. - Submicron arsenic fumes are difficult to control in conventional air pollution control devices

  11. Sampling and characterization of spent exchange resins of Atucha I nuclear power plant

    International Nuclear Information System (INIS)

    Varani, Jose L.; Cernadas, D.; Iglesias, Alberto M.; Raffo Calderon, Maria del C.

    2004-01-01

    The present storage facilities for spent resins in Atucha I NPP would be full within the next 5 years, accordingly some tasks are being planned to conditioning these waste and so generate enough storage capacity for the remaining life of the plant. Among this tasks is the characterization of spent resins that has several objectives: to know their chemical and radiochemical composition; the homogeneity of these parameters in the total volume of spent resins; the existence or not of compact zones; the proportion of 'crud'; the breakage degree of the micro-spheres; etc. The first step was to analyse the criterion to follow for sampling resins in the storage deposit of 40 m 3 . In order to take some samples from different points, a special device was required. It had to be introduced closed in the resin bed, opened to take the sample and then closed again to return to the surface. A device used in cereal industry for sampling silos to different depths was modified in its internal capacity for reducing operator dose and increasing the length of rod in order to reaching the bottom of the pit. The device was tested in cold mock up before to taking actual samples. Active resins samples, five in total up to now, were taken from deposit to different depths and kept in lead containers. After analysing the samples, the following average results were extracted: 1.7 x 10 5 Bq/g of Co-60, 9.7 x 10 5 Bq/g of Cs-137 and 774 Bq/g of total alpha, which corresponds to intermediate activity waste. The differences between the values of activity of the different samples are of up to 310 % for Co-60 and of up to 788 % for the Cs-137 what indicates a great inhomogeneity. The direct observation of resin grains, placed in a transparent glass burette, did not demonstrate an important proportion of broken or divided resins. (author)

  12. Comparison of sampling methods for animal manure

    NARCIS (Netherlands)

    Derikx, P.J.L.; Ogink, N.W.M.; Hoeksma, P.

    1997-01-01

    Currently available and recently developed sampling methods for slurry and solid manure were tested for bias and reproducibility in the determination of total phosphorus and nitrogen content of samples. Sampling methods were based on techniques in which samples were taken either during loading from

  13. Procedures for sampling and sample-reduction within quality assurance systems for solid biofuels

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2005-04-15

    The bias introduced when sampling solid biofuels from stockpiles or containers instead of from moving streams is assessed as well as the number and size of samples required to represent accurately the bulk sample, variations introduced when reducing bulk samples into samples for testing, and the usefulness of sample reduction methods. Details are given of the experimental work carried out in Sweden and Denmark using sawdust, wood chips, wood pellets, forestry residues and straw. The production of a model European Standard for quality assurance of solid biofuels is examined.

  14. Totally parallel multilevel algorithms

    Science.gov (United States)

    Frederickson, Paul O.

    1988-01-01

    Four totally parallel algorithms for the solution of a sparse linear system have common characteristics which become quite apparent when they are implemented on a highly parallel hypercube such as the CM2. These four algorithms are Parallel Superconvergent Multigrid (PSMG) of Frederickson and McBryan, Robust Multigrid (RMG) of Hackbusch, the FFT based Spectral Algorithm, and Parallel Cyclic Reduction. In fact, all four can be formulated as particular cases of the same totally parallel multilevel algorithm, which are referred to as TPMA. In certain cases the spectral radius of TPMA is zero, and it is recognized to be a direct algorithm. In many other cases the spectral radius, although not zero, is small enough that a single iteration per timestep keeps the local error within the required tolerance.

  15. TOTAL REWARDS MODEL IN ROMANIAN COMPANIES

    Directory of Open Access Journals (Sweden)

    Elena-Sabina HODOR

    2014-04-01

    Full Text Available Total Rewards Management is a subject of major importance for companies, because, by using models for this, firms can achieve their objectives of high performance. In order to analyse a validated total rewards model in Romanian Accounting and Consulting Companies, it is used The WorldatWork Total Rewards Model, which depict what contributes to applicant attraction and employee motivation and retention. Thus, the methodology of the previous survey is adjusted to the local context. The conclusions for the methodological aspects illustrate that the present research involves three strategic steps in order to achieve the objectives presented: the analysis of organizational environment of the companies from the sample, checking if Total Rewards Model proposed in the previous research is applicable for the same romanian companies from the previous survey, the analysing of the differences between results, and, if necessary, the adaptation of the model for Romania.

  16. Analysis of the research sample collections of Uppsala biobank.

    Science.gov (United States)

    Engelmark, Malin T; Beskow, Anna H

    2014-10-01

    Uppsala Biobank is the joint and only biobank organization of the two principals, Uppsala University and Uppsala University Hospital. Biobanks are required to have updated registries on sample collection composition and management in order to fulfill legal regulations. We report here the results from the first comprehensive and overall analysis of the 131 research sample collections organized in the biobank. The results show that the median of the number of samples in the collections was 700 and that the number of samples varied from less than 500 to over one million. Blood samples, such as whole blood, serum, and plasma, were included in the vast majority, 84.0%, of the research sample collections. Also, as much as 95.5% of the newly collected samples within healthcare included blood samples, which further supports the concept that blood samples have fundamental importance for medical research. Tissue samples were also commonly used and occurred in 39.7% of the research sample collections, often combined with other types of samples. In total, 96.9% of the 131 sample collections included samples collected for healthcare, showing the importance of healthcare as a research infrastructure. Of the collections that had accessed existing samples from healthcare, as much as 96.3% included tissue samples from the Department of Pathology, which shows the importance of pathology samples as a resource for medical research. Analysis of different research areas shows that the most common of known public health diseases are covered. Collections that had generated the most publications, up to over 300, contained a large number of samples collected systematically and repeatedly over many years. More knowledge about existing biobank materials, together with public registries on sample collections, will support research collaborations, improve transparency, and bring us closer to the goals of biobanks, which is to save and prolong human lives and improve health and quality of life.

  17. Comparing fixed sampling with minimizer sampling when using k-mer indexes to find maximal exact matches.

    Science.gov (United States)

    Almutairy, Meznah; Torng, Eric

    2018-01-01

    Bioinformatics applications and pipelines increasingly use k-mer indexes to search for similar sequences. The major problem with k-mer indexes is that they require lots of memory. Sampling is often used to reduce index size and query time. Most applications use one of two major types of sampling: fixed sampling and minimizer sampling. It is well known that fixed sampling will produce a smaller index, typically by roughly a factor of two, whereas it is generally assumed that minimizer sampling will produce faster query times since query k-mers can also be sampled. However, no direct comparison of fixed and minimizer sampling has been performed to verify these assumptions. We systematically compare fixed and minimizer sampling using the human genome as our database. We use the resulting k-mer indexes for fixed sampling and minimizer sampling to find all maximal exact matches between our database, the human genome, and three separate query sets, the mouse genome, the chimp genome, and an NGS data set. We reach the following conclusions. First, using larger k-mers reduces query time for both fixed sampling and minimizer sampling at a cost of requiring more space. If we use the same k-mer size for both methods, fixed sampling requires typically half as much space whereas minimizer sampling processes queries only slightly faster. If we are allowed to use any k-mer size for each method, then we can choose a k-mer size such that fixed sampling both uses less space and processes queries faster than minimizer sampling. The reason is that although minimizer sampling is able to sample query k-mers, the number of shared k-mer occurrences that must be processed is much larger for minimizer sampling than fixed sampling. In conclusion, we argue that for any application where each shared k-mer occurrence must be processed, fixed sampling is the right sampling method.

  18. Comparing fixed sampling with minimizer sampling when using k-mer indexes to find maximal exact matches.

    Directory of Open Access Journals (Sweden)

    Meznah Almutairy

    Full Text Available Bioinformatics applications and pipelines increasingly use k-mer indexes to search for similar sequences. The major problem with k-mer indexes is that they require lots of memory. Sampling is often used to reduce index size and query time. Most applications use one of two major types of sampling: fixed sampling and minimizer sampling. It is well known that fixed sampling will produce a smaller index, typically by roughly a factor of two, whereas it is generally assumed that minimizer sampling will produce faster query times since query k-mers can also be sampled. However, no direct comparison of fixed and minimizer sampling has been performed to verify these assumptions. We systematically compare fixed and minimizer sampling using the human genome as our database. We use the resulting k-mer indexes for fixed sampling and minimizer sampling to find all maximal exact matches between our database, the human genome, and three separate query sets, the mouse genome, the chimp genome, and an NGS data set. We reach the following conclusions. First, using larger k-mers reduces query time for both fixed sampling and minimizer sampling at a cost of requiring more space. If we use the same k-mer size for both methods, fixed sampling requires typically half as much space whereas minimizer sampling processes queries only slightly faster. If we are allowed to use any k-mer size for each method, then we can choose a k-mer size such that fixed sampling both uses less space and processes queries faster than minimizer sampling. The reason is that although minimizer sampling is able to sample query k-mers, the number of shared k-mer occurrences that must be processed is much larger for minimizer sampling than fixed sampling. In conclusion, we argue that for any application where each shared k-mer occurrence must be processed, fixed sampling is the right sampling method.

  19. Comparing fixed sampling with minimizer sampling when using k-mer indexes to find maximal exact matches

    Science.gov (United States)

    Torng, Eric

    2018-01-01

    Bioinformatics applications and pipelines increasingly use k-mer indexes to search for similar sequences. The major problem with k-mer indexes is that they require lots of memory. Sampling is often used to reduce index size and query time. Most applications use one of two major types of sampling: fixed sampling and minimizer sampling. It is well known that fixed sampling will produce a smaller index, typically by roughly a factor of two, whereas it is generally assumed that minimizer sampling will produce faster query times since query k-mers can also be sampled. However, no direct comparison of fixed and minimizer sampling has been performed to verify these assumptions. We systematically compare fixed and minimizer sampling using the human genome as our database. We use the resulting k-mer indexes for fixed sampling and minimizer sampling to find all maximal exact matches between our database, the human genome, and three separate query sets, the mouse genome, the chimp genome, and an NGS data set. We reach the following conclusions. First, using larger k-mers reduces query time for both fixed sampling and minimizer sampling at a cost of requiring more space. If we use the same k-mer size for both methods, fixed sampling requires typically half as much space whereas minimizer sampling processes queries only slightly faster. If we are allowed to use any k-mer size for each method, then we can choose a k-mer size such that fixed sampling both uses less space and processes queries faster than minimizer sampling. The reason is that although minimizer sampling is able to sample query k-mers, the number of shared k-mer occurrences that must be processed is much larger for minimizer sampling than fixed sampling. In conclusion, we argue that for any application where each shared k-mer occurrence must be processed, fixed sampling is the right sampling method. PMID:29389989

  20. Comparative Study between Standard and Totally Tubeless Percutaneous Nephrolithotomy.

    Science.gov (United States)

    Yun, Sung Il; Lee, Yoon Hyung; Kim, Jae Soo; Cho, Sung Ryong; Kim, Bum Soo; Kwon, Joon Beom

    2012-11-01

    Several recent studies have reported the benefits of tubeless percutaneous nephrolithotomy (PNL). Postoperatively, tubeless PNL patients have an indwelling ureteral stent placed, which is often associated with stent-related morbidity. We have performed totally tubeless (tubeless and stentless) PNL in which no nephrostomy tube or ureteral stent is placed postoperatively. We evaluated the safety, effectiveness, and feasibility of totally tubeless PNL. From March 2008 to February 2012, 57 selected patients underwent standard or totally tubeless PNL. Neither a nephrostomy tube nor a ureteral stent was placed in the totally tubeless PNL group. We compared patient and stone characteristics, operation time, length of hospitalization, analgesia requirements, stone-free rate, blood loss, change in creatinine, and perioperative complications between the standard and totally tubeless PNL groups. There were no significant differences in preoperative patient characteristics, postoperative complications, or the stone-free rate between the two groups, but the totally tubeless PNL group showed a shorter hospitalization and a lesser analgesic requirement compared with the standard PNL group. Blood loss and change in creatinine were not significantly different between the two groups. Totally tubeless PNL appears to be a safe and effective alternative for the management of renal stone patients and is associated with a decrease in length of hospital stay.

  1. Comparison of Microwave Assisted Acid Digestion Methods for ICP-MS Determination of Total Arsenic in Fish Tissue

    International Nuclear Information System (INIS)

    Ghanthimathi, S.; Aminah Abdullah; Salmijah, S.; Ujang, T.; Nurul, I.A.

    2012-01-01

    Fish is one of the most important sources of arsenic exposure in human diet and the Food Safety and Quality Division, Ministry of Health since 2007 has required routine monitoring of total arsenic in sea foods such as fish. This study describes an improved extraction method of total arsenic in fish using microwave assisted acid digestion procedure before being analysed by inductively coupled plasma mass spectrometry (ICP-MS). The parameters studied were pre-treatment of sample, digestion temperature, time programme and the chemicals (HNO 3 / H 2 O 2 ) used. Arsenic contents in fish samples under these conditions were compared using the standards additions technique. Microwave assisted acid digestion method with a combination of ultrapure concentrated nitric acid (HNO 3 ) to concentrated hydrogen peroxide (H 2 O 2 ) at a ratio of 7 mL: 1 mL, run time of 25 min and digestion temperature of 200 degree Celsius with no pre-treatment was found to have recovery of 100.7 % as compared to other digestion procedure where the recovery were 115.5, 111.6 and 101.8 %. Validation using certified reference material (CRM) of fish tissue (DORM-3) showed a recovery of 101.4 ± 2.5 % for total arsenic from the CRM. (author)

  2. Donor hematopoiesis in mice following total lymphoid irradiation requires host T-regulatory cells for durable engraftment

    Science.gov (United States)

    Müller, Antonia M. S.; Poyser, Jessica; Küpper, Natascha J.; Burnett, Cassandra; Ko, Rose M.; Kohrt, Holbrook E.K.; Florek, Mareike; Zhang, Pei; Negrin, Robert S.

    2014-01-01

    Total lymphoid irradiation (TLI) with antithymocyte globulin (ATG) is a unique regimen that prepares recipients for allogeneic hematopoietic cell transplantation by targeting lymph nodes, while sparing large areas of the bone marrow. TLI is reported to increase the frequency of CD4+CD25+FoxP3+ T-regulatory cells (Treg) relative to conventional T cells. In this study, barriers to hematopoietic stem cell (HSC) engraftment following this nonmyeloablative conditioning were evaluated. TLI/ATG resulted in profound lymphoablation but endogenous host HSC remained. Initial donor HSC engraftment occurred only in radiation exposed marrow sites, but gradually distributed to bone marrow outside the radiation field. Sustained donor engraftment required host lymphoid cells insofar as lymphocyte deficient Rag2γc−/− recipients had unstable engraftment compared with wild-type. TLI/ATG treated wild-type recipients had increased proportions of Treg that were associated with increased HSC frequency and proliferation. In contrast, Rag2γc−/− recipients who lacked Treg did not. Adoptive transfer of Treg into Rag2γc−/− recipients resulted in increased cell cycling of endogenous HSC. Thus, we hypothesize that Treg influence donor engraftment post-TLI/ATG by increasing HSC cell cycling, thereby promoting the exit of host HSC from the marrow niche. Our study highlights the unique dynamics of donor hematopoiesis following TLI/ATG, and the effect of Treg on HSC activity. PMID:24591203

  3. Chapter 4: Measurements of total beta-activity in the fallout

    International Nuclear Information System (INIS)

    Duggleby, J.C.; Johannessen, J.C.; Kotler, L.H.; Stewart, F.M.

    1974-01-01

    In order to provide information on fresh fission products in fallout reaching Australia from nuclear tests being conducted by France in Polynesia, measurements were made of total beta activity in daily fallout deposition of 25 Australian sampling stations covering a three month period from 25 July to 23 October 1973. The methods employed to measure the radioactivity of the samples are described and the data on total beta-activity, and the calculated external gamma radiation doses from fresh fallout are presented. (R.L.)

  4. Total and available metal contents in sediments by synchrotron radiation total reflection X-ray fluorescence

    International Nuclear Information System (INIS)

    Moreira, Silvana; Sobrinho, Gilmar A.; Jesus, Edgar F.O. de; Lopes, Ricardo T.

    2002-01-01

    In this work the total and available contents of Al, Si, Cl, K, Mn, Fe, Co, Ni, Cu, Zn, Sr, Zr, Ba, Ce and Pb in sediments from river Atibaia were determined by Synchrotron Radiation Total Reflection X-Ray Fluorescence technique. The detection limits for K series varies from 200 ng.mL -1 for Al to 2 ng.mL -1 for Zn while for L series the value varies from 20 ng.mL -1 for Ba to 10 ng.mL -1 for Pb. The samples were submitted to two different processes, in order to obtain the total and biological available metal contents. The information about metal content is a important parameter for a correct evaluation about the hydrologic cycle in Piracicaba basin. All the measure were carried out at the National Synchrotron Light Laboratory, Campinas, SP, Brazil, using a white beam for excitation. (author)

  5. Preliminary vitrinite and bitumen reflectance, total organic carbon, and pyrolysis data for samples from Upper and Lower Cretaceous strata, Maverick Basin, south Texas

    Science.gov (United States)

    Hackley, Paul C.; Dennen, Kristin O.; Gesserman, Rachel M.; Ridgley, Jennie L.

    2009-01-01

    The Lower Cretaceous Pearsall Formation, a regionally occurring limestone and shale interval of 500-600-ft maximum thickness (Rose, 1986), is being evaluated as part of an ongoing U.S. Geological Survey (USGS) assessment of undiscovered hydrocarbon resources in onshore Lower Cretaceous strata of the northern Gulf of Mexico. The purpose of this report is to release preliminary vitrinite and bitumen reflectance, total organic carbon, and pyrolysis data for Pearsall Formation, Glen Rose Formation, Hosston Formation, Austin Group, and Eagle Ford Group samples from the Maverick Basin in south Texas in order to aid in the characterization of these strata in this area. The preliminary nature of this report and the data contained herein reflect that the assessment and characterization of these samples is a work currently in progress. Pearsall Formation subdivisions are, in ascending stratigraphic order, the Pine Island Shale, James Limestone, and Bexar Shale Members (Loucks, 2002). The Lower Cretaceous Glen Rose Formation is also part of the USGS Lower Cretaceous assessment and produces oil in the Maverick Basin (Loucks and Kerans, 2003). The Hosston Formation was assessed by the USGS for undiscovered oil and gas resources in 2006 (Dyman and Condon, 2006), but not in south Texas. The Upper Cretaceous Austin Group is being assessed as part of the USGS assessment of undiscovered hydrocarbon resources in the Upper Cretaceous strata of the northern Gulf of Mexico and, along with the Upper Cretaceous Eagle Ford Group, is considered to be an important source rock in the Smackover-Austin-Eagleford Total Petroleum System (Condon and Dyman, 2006). Both the Austin Group and the Eagle Ford Group are present in the Maverick Basin in south Texas (Rose, 1986).

  6. Accuracy of different sensors for the estimation of pollutant concentrations (total suspended solids, total and dissolved chemical oxygen demand) in wastewater and stormwater.

    Science.gov (United States)

    Lepot, Mathieu; Aubin, Jean-Baptiste; Bertrand-Krajewski, Jean-Luc

    2013-01-01

    Many field investigations have used continuous sensors (turbidimeters and/or ultraviolet (UV)-visible spectrophotometers) to estimate with a short time step pollutant concentrations in sewer systems. Few, if any, publications compare the performance of various sensors for the same set of samples. Different surrogate sensors (turbidity sensors, UV-visible spectrophotometer, pH meter, conductivity meter and microwave sensor) were tested to link concentrations of total suspended solids (TSS), total and dissolved chemical oxygen demand (COD), and sensors' outputs. In the combined sewer at the inlet of a wastewater treatment plant, 94 samples were collected during dry weather, 44 samples were collected during wet weather, and 165 samples were collected under both dry and wet weather conditions. From these samples, triplicate standard laboratory analyses were performed and corresponding sensors outputs were recorded. Two outlier detection methods were developed, based, respectively, on the Mahalanobis and Euclidean distances. Several hundred regression models were tested, and the best ones (according to the root mean square error criterion) are presented in order of decreasing performance. No sensor appears as the best one for all three investigated pollutants.

  7. An Employee Total Health Management–Based Survey of Iowa Employers

    Science.gov (United States)

    Merchant, James A.; Lind, David P.; Kelly, Kevin M.; Hall, Jennifer L.

    2015-01-01

    Objective To implement an Employee Total Health Management (ETHM) model-based questionnaire and provide estimates of model program elements among a statewide sample of Iowa employers. Methods Survey a stratified random sample of Iowa employers, characterize and estimate employer participation in ETHM program elements Results Iowa employers are implementing under 30% of all 12 components of ETHM, with the exception of occupational safety and health (46.6%) and worker compensation insurance coverage (89.2%), but intend modest expansion of all components in the coming year. Conclusions The Employee Total Health Management questionnaire-based survey provides estimates of progress Iowa employers are making toward implementing components of total worker health programs. PMID:24284757

  8. Sampling Methodologies for Epidemiologic Surveillance of Men Who Have Sex with Men and Transgender Women in Latin America: An Empiric Comparison of Convenience Sampling, Time Space Sampling, and Respondent Driven Sampling

    OpenAIRE

    Clark, J. L.; Konda, K. A.; Silva-Santisteban, A.; Peinado, J.; Lama, J. R.; Kusunoki, L.; Perez-Brumer, A.; Pun, M.; Cabello, R.; Sebastian, J. L.; Suarez-Ognio, L.; Sanchez, J.

    2014-01-01

    Alternatives to convenience sampling (CS) are needed for HIV/STI surveillance of most-at-risk populations in Latin America. We compared CS, time space sampling (TSS), and respondent driven sampling (RDS) for recruitment of men who have sex with men (MSM) and transgender women (TW) in Lima, Peru. During concurrent 60-day periods from June-August, 2011, we recruited MSM/TW for epidemiologic surveillance using CS, TSS, and RDS. A total of 748 participants were recruited through CS, 233 through T...

  9. Total antioxidant capacity, total phenolic content and mineral elements in the fruit peel of Myrciaria cauliflora

    Directory of Open Access Journals (Sweden)

    Clináscia Rodrigues Rocha Araújo

    2013-12-01

    Full Text Available The in vitro antioxidant capacity, total phenolic content and mineral elements of the fruit peel of Myrciaria cauliflora were investigated. The antioxidant capacity was analyzed by the diphenylpicrylhydrazyl (DPPH, 2,2'-azino-bis(3-ethylbenzthiazoline-6-sulfonic acid (ABTS, ferric reducing antioxidant power (FRAP and β-carotene methods. The assays based on the DPPH (EC50 = 3.18 g sample/g DPPH, ABTS•+ (1017 μmol Trolox/g sample, FRAP (1676 µM Fe2SO4/g sample and β-carotene/linoleic acid (70% of oxidation inhibition methods indicated a high antioxidant capacity of the fruit peel extract of the plant. The Folin-Denis method was more efficient in determining the total phenolic compound contents in the different solvents than the Folin-Ciocalteu one. Extractions made with 4:1 methanol-water, 4:1 ethanol-water, 3:2 ethanol-water and 3:2 acetone-water solutions using the Folin-Denis method exhibited high contents of phenolic compounds (18.95, 14.06, 12.93 and 11.99 mg GAE/g, respectively. Potassium was the major element found in the fruit peel, followed by phosphorus, calcium, magnesium and iron, in that order. As a result, the fruit peel of M. cauliflora can be considered as an important source of natural antioxidants and essential elements of easy access for the population and for application in the food industry.

  10. Galaxy redshift surveys with sparse sampling

    International Nuclear Information System (INIS)

    Chiang, Chi-Ting; Wullstein, Philipp; Komatsu, Eiichiro; Jee, Inh; Jeong, Donghui; Blanc, Guillermo A.; Ciardullo, Robin; Gronwall, Caryl; Hagen, Alex; Schneider, Donald P.; Drory, Niv; Fabricius, Maximilian; Landriau, Martin; Finkelstein, Steven; Jogee, Shardha; Cooper, Erin Mentuch; Tuttle, Sarah; Gebhardt, Karl; Hill, Gary J.

    2013-01-01

    Survey observations of the three-dimensional locations of galaxies are a powerful approach to measure the distribution of matter in the universe, which can be used to learn about the nature of dark energy, physics of inflation, neutrino masses, etc. A competitive survey, however, requires a large volume (e.g., V survey ∼ 10Gpc 3 ) to be covered, and thus tends to be expensive. A ''sparse sampling'' method offers a more affordable solution to this problem: within a survey footprint covering a given survey volume, V survey , we observe only a fraction of the volume. The distribution of observed regions should be chosen such that their separation is smaller than the length scale corresponding to the wavenumber of interest. Then one can recover the power spectrum of galaxies with precision expected for a survey covering a volume of V survey (rather than the volume of the sum of observed regions) with the number density of galaxies given by the total number of observed galaxies divided by V survey (rather than the number density of galaxies within an observed region). We find that regularly-spaced sampling yields an unbiased power spectrum with no window function effect, and deviations from regularly-spaced sampling, which are unavoidable in realistic surveys, introduce calculable window function effects and increase the uncertainties of the recovered power spectrum. On the other hand, we show that the two-point correlation function (pair counting) is not affected by sparse sampling. While we discuss the sparse sampling method within the context of the forthcoming Hobby-Eberly Telescope Dark Energy Experiment, the method is general and can be applied to other galaxy surveys

  11. Influence of Sampling Effort on the Estimated Richness of Road-Killed Vertebrate Wildlife

    Science.gov (United States)

    Bager, Alex; da Rosa, Clarissa A.

    2011-05-01

    Road-killed mammals, birds, and reptiles were collected weekly from highways in southern Brazil in 2002 and 2005. The objective was to assess variation in estimates of road-kill impacts on species richness produced by different sampling efforts, and to provide information to aid in the experimental design of future sampling. Richness observed in weekly samples was compared with sampling for different periods. In each period, the list of road-killed species was evaluated based on estimates the community structure derived from weekly samplings, and by the presence of the ten species most subject to road mortality, and also of threatened species. Weekly samples were sufficient only for reptiles and mammals, considered separately. Richness estimated from the biweekly samples was equal to that found in the weekly samples, and gave satisfactory results for sampling the most abundant and threatened species. The ten most affected species showed constant road-mortality rates, independent of sampling interval, and also maintained their dominance structure. Birds required greater sampling effort. When the composition of road-killed species varies seasonally, it is necessary to take biweekly samples for a minimum of one year. Weekly or more-frequent sampling for periods longer than two years is necessary to provide a reliable estimate of total species richness.

  12. Qualità totale e mobilità totale Total Quality and Total Mobility

    Directory of Open Access Journals (Sweden)

    Giuseppe Trieste

    2010-05-01

    Full Text Available FIABA ONLUS (Italian Fund for Elimination of Architectural Barriers was founded in 2000 with the aim of promoting a culture of equal opportunities and, above all, it has as its main goal to involve public and private institutions to create a really accessible and usable environment for everyone. Total accessibility, Total usability and Total mobility are key indicators to define quality of life within cities. A supportive environment that is free of architectural, cultural and psychological barriers allows everyone to live with ease and universality. In fact, people who access to goods and services in the urban context can use to their advantage time and space, so they can do their activities and can maintain relationships that are deemed significant for their social life. The main aim of urban accessibility is to raise the comfort of space for citizens, eliminating all barriers that discriminate people, and prevent from an equality of opportunity. “FIABA FUND - City of ... for the removal of architectural barriers” is an idea of FIABA that has already affected many regions of Italy as Lazio, Lombardy, Campania, Abruzzi and Calabria. It is a National project which provides for opening a bank account in the cities of referring, in which for the first time, all together, individuals and private and public institutions can make a donation to fund initiatives for the removal of architectural barriers within its own territory for a real and effective total accessibility. Last February the fund was launched in Rome with the aim of achieving a Capital without barriers and a Town European model of accessibility and usability. Urban mobility is a prerequisite to access to goods and services, and to organize activities related to daily life. FIABA promotes the concept of sustainable mobility for all, supported by the European Commission’s White Paper. We need a cultural change in management and organization of public means, which might focus on

  13. Total joint Perioperative Surgical Home: an observational financial review.

    Science.gov (United States)

    Raphael, Darren R; Cannesson, Maxime; Schwarzkopf, Ran; Garson, Leslie M; Vakharia, Shermeen B; Gupta, Ranjan; Kain, Zeev N

    2014-01-01

    The numbers of people requiring total arthroplasty is expected to increase substantially over the next two decades. However, increasing costs and new payment models in the USA have created a sustainability gap. Ad hoc interventions have reported marginal cost reduction, but it has become clear that sustainability lies only in complete restructuring of care delivery. The Perioperative Surgical Home (PSH) model, a patient-centered and physician-led multidisciplinary system of coordinated care, was implemented at UC Irvine Health in 2012 for patients undergoing primary elective total knee arthroplasty (TKA) or total hip arthroplasty (THA). This observational study examines the costs associated with this initiative. The direct cost of materials and services (excluding professional fees and implants) for a random index sample following the Total Joint-PSH pathway was used to calculate per diem cost. Cost of orthopedic implants was calculated based on audit-verified direct cost data. Operating room and post-anesthesia care unit time-based costs were calculated for each case and analyzed for variation. Benchmark cost data were obtained from literature search. Data are presented as mean ± SD (coefficient of variation) where possible. Total per diem cost was $10,042 ± 1,305 (13%) for TKA and $9,952 ± 1,294 (13%) for THA. Literature-reported benchmark per diem cost was $17,588 for TKA and $16,267 for THA. Implant cost was $7,482 ± 4,050 (54%) for TKA and $9869 ± 1,549 (16%) for THA. Total hospital cost was $17,894 ± 4,270 (24%) for TKA and $20,281 ± 2,057 (10%) for THA. In-room to incision time cost was $1,263 ± 100 (8%) for TKA and $1,341 ± 145 (11%) for THA. Surgery time cost was $1,558 ± 290 (19%) for TKA and $1,930 ± 374 (19%) for THA. Post-anesthesia care unit time cost was $507 ± 187 (36%) for TKA and $557 ± 302 (54%) for THA. Direct hospital costs were driven substantially below USA benchmark levels using the Total Joint-PSH pathway. The incremental

  14. In-plane sampling requirements of MR reprojection angiography

    International Nuclear Information System (INIS)

    MacFall, J.R.; Grist, T.M.; Spritzer, C.E.; Evans, A.J.

    1989-01-01

    MR angiograms constructed by reprojection of rapid, sequential, thin-section, flow-compensated acquisitions can produce good-quality images of vasculature. When many sections are required, an unrealistic acquisition time of several hours will be needed if the in-plane resolution is 128 x 256. The scan time can be reduced by using a smaller number (Np) of phase-encoding steps. If the reprojection direction is parallel to the phase-encoding direction, the resolution of the resulting angiogram is preserved. The amount of possible reduction of Np was investigated by acquiring data with varying resolution in the phase-encoding direction through reduction of the phase-encoding gradient. The signal of a typical vessel improved by more than a factor of five as the resolution was reduced, with little loss in the quality of the angiogram. This indicated that scan time for this technique could be reduced

  15. Mycological Survey and Total Aflatoxin Analyze in Silage from Qaemshahr City (Northern Iran

    Directory of Open Access Journals (Sweden)

    M. Hashemi

    2012-10-01

    Full Text Available In this study, 42 samples of silage were collected in Qaemshahr city in Iran during fall 2011. Samples were tested by competitive ELISA for total aflatoxins. Seven samples (16.7% (Mean±se:1.24 from 42 silage samples were positive with total aflatoxin (1.1-27.3 ppb in Nov., Dec. and Oct. The highest contamination was observed in Oct., three samples (21.4% from 14 samples were contaminated with total aflatoxin by 22.2 ppb, 25.6 and 27.3 ppb. The culture results of samples showed that the most toxinigenic fungi among 57 colonies were Aspergillus sp. with fifteen (% 31.5, Fusarium sp. With thirteen (% 22.8, Alternaria spp. With twelve (21.05%, Penicillium spp. with nine (%15.78 and Acremonium sp. with five (8.77% and also the most nontoxigenic fungi were cladosporium spp. with fifteen (% 37.5, Rhizopus spp. with nine (% 22.5, Mucor spp. with six (15%, yeast with six (15% and Scopulariopsis spp. with four (10% colonies isolated in culture medium among 40 colonies of nontoxigenic fungi.

  16. Sampling artifacts in measurement of elemental and organic carbon: Low-volume sampling in indoor and outdoor environments

    Science.gov (United States)

    Olson, David A.; Norris, Gary A.

    Experiments were completed to determine the extent of artifacts from sampling elemental carbon (EC) and organic carbon (OC) under sample conditions consistent with personal sampling. Two different types of experiments were completed; the first examined possible artifacts from oils used in personal environmental monitor (PEM) impactor plates, and the second examined artifacts from microenvironmental sampling using different sampling media combinations (quartz, Teflon, XAD denuder, and electrostatic precipitator). The effectiveness of front and backup filters was evaluated for most sampling configurations. Mean total carbon concentrations from sampling configurations using impactor oils were not statistically different from the control case (using a sharp cut cyclone). Three microenvironments were tested (kitchen, library, and ambient); carbon concentrations were highest in the kitchen using a front quartz filter (mean OC of 16.4 μg m -3). The lowest front quartz filter concentrations were measured in the library using XAD denuders (mean OC of 3.6 μg m -3). Denuder removal efficiencies (average of 82% for total carbon) were lower compared with previous ambient studies and may indicate that indoor sources influenced denuder efficiency during sample collection. The highest carbon concentrations from backup quartz filters were measured using the Teflon-quartz combination.

  17. Improving the Yield of Histological Sampling in Patients With Suspected Colorectal Cancer During Colonoscopy by Introducing a Colonoscopy Quality Assurance Program.

    Science.gov (United States)

    Gado, Ahmed; Ebeid, Basel; Abdelmohsen, Aida; Axon, Anthony

    2011-08-01

    Masses discovered by clinical examination, imaging or endoscopic studies that are suspicious for malignancy typically require biopsy confirmation before treatment is initiated. Biopsy specimens may fail to yield a definitive diagnosis if the lesion is extensively ulcerated or otherwise necrotic and viable tumor tissue is not obtained on sampling. The diagnostic yield is improved when multiple biopsy samples (BSs) are taken. A colonoscopy quality-assurance program (CQAP) was instituted in 2003 in our institution. The aim of this study was to determine the effect of instituting a CQAP on the yield of histological sampling in patients with suspected colorectal cancer (CRC) during colonoscopy. Initial assessment of colonoscopy practice was performed in 2003. A total of five patients with suspected CRC during colonoscopy were documented in 2003. BSs confirmed CRC in three (60%) patients and were nondiagnostic in two (40%). A quality-improvement process was instituted which required a minimum six BSs with adequate size of the samples from any suspected CRC during colonoscopy. A total of 37 patients for the period 2004-2010 were prospectively assessed. The diagnosis of CRC was confirmed with histological examination of BSs obtained during colonoscopy in 63% of patients in 2004, 60% in 2005, 50% in 2006, 67% in 2007, 100% in 2008, 67% in 2009 and 100% in 2010. The yield of histological sampling increased significantly ( p quality assurance and improvement program increased the yield of histological sampling in patients with suspected CRC during colonoscopy.

  18. Standard test method for analysis of total and isotopic uranium and total thorium in soils by inductively coupled plasma-mass spectrometry

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 This test method covers the measurement of total uranium (U) and thorium (Th) concentrations in soils, as well as the determination of the isotopic weight percentages of 234U, 235U, 236U, and 238U, thereby allowing for the calculation of individual isotopic uranium activity or total uranium activity. This inductively coupled plasma-mass spectroscopy (ICP-MS) method is intended as an alternative analysis to methods such as alpha spectroscopy or thermal ionization mass spectroscopy (TIMS). Also, while this test method covers only those isotopes listed above, the instrumental technique may be expanded to cover other long-lived radioisotopes since the preparation technique includes the preconcentration of the actinide series of elements. The resultant sample volume can be further reduced for introduction into the ICP-MS via an electrothermal vaporization (ETV) unit or other sample introduction device, even though the standard peristaltic pump introduction is applied for this test method. The sample preparatio...

  19. Application of total reflection X-ray fluorescence spectrometry for ...

    Indian Academy of Sciences (India)

    Applicability of total reflection X-ray fluorescence (TXRF) spectrometry for trace elemental analysis of rainwater samples was studied. The study was used to develop these samples as rainwater standards by the National University of Singapore (NUS). Our laboratory was one of the participants to use TXRF for this study.

  20. Antibiotic impregnated total femur spacers: a technical tip

    Directory of Open Access Journals (Sweden)

    Colin D. Canham, MD

    2018-03-01

    Full Text Available Simultaneous prosthetic joint infection of ipsilateral hip and knee arthroplasties is often accompanied by significant bone loss and presents a challenging reconstructive problem. Two-stage reconstruction is favored and requires the placement of a total femur spacer, which is not a commercially available device. We describe a surgical technique, reporting on 2 cases in which a customized total femur antibiotic impregnated spacer was created by combining an articulating knee spacer and an articulating hip spacer with a reinforced cement dowel construct connecting the 2 spacers. Custom total femoral spacers are useful in the management of infected femoral megaprostheses and cases with ipsilateral injected hip and knee arthroplasties and severe femoral bone loss. Keywords: total femur spacer, revision arthroplasty, total hip arthroplasty, total knee arthroplasty, prosthetic joint infection

  1. Ethnic variation in the correlation between waist to height ratio and total daily insulin requirement in children with type 1 diabetes: a cross-sectional study.

    Science.gov (United States)

    Uday, Suma; Gorman, Shaun; Feltbower, Richard G; Mathai, Mathew

    2017-03-01

    Total daily insulin required to achieve glycaemic control in type 1 diabetes (T1D) depends on numerous factors. Correlation of insulin requirement to body mass index and waist circumference has been variably reported in the literature and that of waist-to-height ratio has not been studied. To study the correlation between daily insulin requirement [total daily dose (TDD)] and waist-to-height ratio (WHtR) in a multiethnic population. A cross-sectional study of children (5-18 years) with T1D attending a diabetes clinic in a multiethnic population in Bradford, UK was conducted. Physical measurements were undertaken in the clinic setting and data collected from case notes and patients/carers. Sixty nine patients with mean age 12.7(±3.1) yr, duration of diabetes 5.4(±3.5) yr and hemoglobin A1c (HbA1c) 80(±18)mmol/mol(9.5 ± 1.6%) were recruited. Nearly 54% (n = 37) were white and 46% were non-white (29 Asian Pakistani; 1 Indian; 2 mixed White Afro-Caribbean). The two groups had similar demographics and disease profiles. Non-whites compared with whites had a higher prevalence of obesity (15 vs 5%, p 1), family history of type 2 diabetes (T2D) (49% vs. 33%), microalbuminuria (22% vs. 11%, p 1). WHtR and TDD were poorly correlated in the whole group. There was however a significant positive correlation in Caucasians (r = 0.583, N = 37, p 1) and a negative correlation in Asian Pakistanis (r = -0.472, N = 32, p 1); with a significant negative correlation seen in subjects with relatives with T2D (r = -0.86, N = 6, p = 0.02). The variation in correlations highlights that the two ethnic groups behave differently and should therefore be studied separately with regards to factors influencing insulin requirements with careful consideration to the presence of parental IR. Further prospective studies are required to explore the reasons for these differences. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  2. Total effective dose equivalent associated with fixed uranium surface contamination

    International Nuclear Information System (INIS)

    Bogard, J.S.; Hamm, R.N.; Ashley, J.C.; Turner, J.E.; England, C.A.; Swenson, D.E.; Brown, K.S.

    1997-04-01

    This report provides the technical basis for establishing a uranium fixed-contamination action level, a fixed uranium surface contamination level exceeding the total radioactivity values of Appendix D of Title 10, Code of Federal Regulations, part 835 (10CFR835), but below which the monitoring, posting, and control requirements for Radiological Areas are not required for the area of the contamination. An area of fixed uranium contamination between 1,000 dpm/100 cm 2 and that level corresponding to an annual total effective dose equivalent (TEDE) of 100 mrem requires only routine monitoring, posting to alert personnel of the contamination, and administrative control. The more extensive requirements for monitoring, posting, and control designated by 10CFR835 for Radiological Areas do not have to be applied for these intermediate fixed-contamination levels

  3. Measurement of radioactivity in the environment - Soil - Part 2: Guidance for the selection of the sampling strategy, sampling and pre-treatment of samples

    International Nuclear Information System (INIS)

    2007-01-01

    This part of ISO 18589 specifies the general requirements, based on ISO 11074 and ISO/IEC 17025, for all steps in the planning (desk study and area reconnaissance) of the sampling and the preparation of samples for testing. It includes the selection of the sampling strategy, the outline of the sampling plan, the presentation of general sampling methods and equipment, as well as the methodology of the pre-treatment of samples adapted to the measurements of the activity of radionuclides in soil. This part of ISO 18589 is addressed to the people responsible for determining the radioactivity present in soil for the purpose of radiation protection. It is applicable to soil from gardens, farmland, urban or industrial sites, as well as soil not affected by human activities. This part of ISO 18589 is applicable to all laboratories regardless of the number of personnel or the range of the testing performed. When a laboratory does not undertake one or more of the activities covered by this part of ISO 18589, such as planning, sampling or testing, the corresponding requirements do not apply. Information is provided on scope, normative references, terms and definitions and symbols, principle, sampling strategy, sampling plan, sampling process, pre-treatment of samples and recorded information. Five annexes inform about selection of the sampling strategy according to the objectives and the radiological characterization of the site and sampling areas, diagram of the evolution of the sample characteristics from the sampling site to the laboratory, example of sampling plan for a site divided in three sampling areas, example of a sampling record for a single/composite sample and example for a sample record for a soil profile with soil description. A bibliography is provided

  4. Standard characterization of phosphate rock samples from the FAO/IAEA phosphate project

    International Nuclear Information System (INIS)

    Binh, Truong; Zapata, F.

    2002-01-01

    Phosphate rocks (PR) are phosphate-bearing minerals that vary widely in their inherent characteristics and consequently their agronomic potential. In the framework of a FAO/IAEA networked research project, the evaluation of the agronomic effectiveness of natural and modified PR products under a variety of soil climate and crop management conditions was carried out. The characterization of phosphate rocks is the first and essential step in evaluating their suitability for direct application. If several PR sources are utilized, standardized methods should be used for comparison purposes to determine their agronomic potential. This paper describes the standard characterization of phosphate rock products utilized in the project, in particular the mineralogical and crystallographic analyses, physical analyses, chemical composition and solubility in conventional reagents. A total of 28 phosphate rock samples from 15 countries were collected and analyzed in specialized laboratories. The data on mineralogy, chemical composition and solubility in conventional reagents are closely interrelated. An arbitrary classification of the reactivity of the PR samples was made based on the solubility indices in conventional reagents. On another hand, the results of the crystallographic parameters, calculated indices of absolute solubility, specific surface and porosity reflect the variability of the physical state and the sample pre-conditioning treatment of the analyzed products. A proper characterization of phosphate rock samples should provide the maximum of basic information that can be obtained in a cost-effective manner in normal chemical laboratories. Based on the results of this characterization, the following determinations are recommended: a description of the sample, major elemental (total P, Ca, Mg) composition, solubility in conventional reagents (neutral ammonium citrate, citric and formic acid) and particle size analysis. The classification of PR samples for direct

  5. Direct quantification of lipopeptide biosurfactants in biological samples via HPLC and UPLC-MS requires sample modification with an organic solvent.

    Science.gov (United States)

    Biniarz, Piotr; Łukaszewicz, Marcin

    2017-06-01

    The rapid and accurate quantification of biosurfactants in biological samples is challenging. In contrast to the orcinol method for rhamnolipids, no simple biochemical method is available for the rapid quantification of lipopeptides. Various liquid chromatography (LC) methods are promising tools for relatively fast and exact quantification of lipopeptides. Here, we report strategies for the quantification of the lipopeptides pseudofactin and surfactin in bacterial cultures using different high- (HPLC) and ultra-performance liquid chromatography (UPLC) systems. We tested three strategies for sample pretreatment prior to LC analysis. In direct analysis (DA), bacterial cultures were injected directly and analyzed via LC. As a modification, we diluted the samples with methanol and detected an increase in lipopeptide recovery in the presence of methanol. Therefore, we suggest this simple modification as a tool for increasing the accuracy of LC methods. We also tested freeze-drying followed by solvent extraction (FDSE) as an alternative for the analysis of "heavy" samples. In FDSE, the bacterial cultures were freeze-dried, and the resulting powder was extracted with different solvents. Then, the organic extracts were analyzed via LC. Here, we determined the influence of the extracting solvent on lipopeptide recovery. HPLC methods allowed us to quantify pseudofactin and surfactin with run times of 15 and 20 min per sample, respectively, whereas UPLC quantification was as fast as 4 and 5.5 min per sample, respectively. Our methods provide highly accurate measurements and high recovery levels for lipopeptides. At the same time, UPLC-MS provides the possibility to identify lipopeptides and their structural isoforms.

  6. Rapid filtration separation-based sample preparation method for Bacillus spores in powdery and environmental matrices.

    Science.gov (United States)

    Isabel, Sandra; Boissinot, Maurice; Charlebois, Isabelle; Fauvel, Chantal M; Shi, Lu-E; Lévesque, Julie-Christine; Paquin, Amélie T; Bastien, Martine; Stewart, Gale; Leblanc, Eric; Sato, Sachiko; Bergeron, Michel G

    2012-03-01

    Authorities frequently need to analyze suspicious powders and other samples for biothreat agents in order to assess environmental safety. Numerous nucleic acid detection technologies have been developed to detect and identify biowarfare agents in a timely fashion. The extraction of microbial nucleic acids from a wide variety of powdery and environmental samples to obtain a quality level adequate for these technologies still remains a technical challenge. We aimed to develop a rapid and versatile method of separating bacteria from these samples and then extracting their microbial DNA. Bacillus atrophaeus subsp. globigii was used as a simulant of Bacillus anthracis. We studied the effects of a broad variety of powdery and environmental samples on PCR detection and the steps required to alleviate their interference. With a benchmark DNA extraction procedure, 17 of the 23 samples investigated interfered with bacterial lysis and/or PCR-based detection. Therefore, we developed the dual-filter method for applied recovery of microbial particles from environmental and powdery samples (DARE). The DARE procedure allows the separation of bacteria from contaminating matrices that interfere with PCR detection. This procedure required only 2 min, while the DNA extraction process lasted 7 min, for a total of sample preparation procedure allowed the recovery of cleaned bacterial spores and relieved detection interference caused by a wide variety of samples. Our procedure was easily completed in a laboratory facility and is amenable to field application and automation.

  7. Subrandom methods for multidimensional nonuniform sampling.

    Science.gov (United States)

    Worley, Bradley

    2016-08-01

    Methods of nonuniform sampling that utilize pseudorandom number sequences to select points from a weighted Nyquist grid are commonplace in biomolecular NMR studies, due to the beneficial incoherence introduced by pseudorandom sampling. However, these methods require the specification of a non-arbitrary seed number in order to initialize a pseudorandom number generator. Because the performance of pseudorandom sampling schedules can substantially vary based on seed number, this can complicate the task of routine data collection. Approaches such as jittered sampling and stochastic gap sampling are effective at reducing random seed dependence of nonuniform sampling schedules, but still require the specification of a seed number. This work formalizes the use of subrandom number sequences in nonuniform sampling as a means of seed-independent sampling, and compares the performance of three subrandom methods to their pseudorandom counterparts using commonly applied schedule performance metrics. Reconstruction results using experimental datasets are also provided to validate claims made using these performance metrics. Copyright © 2016 Elsevier Inc. All rights reserved.

  8. Total-Evidence Dating under the Fossilized Birth-Death Process.

    Science.gov (United States)

    Zhang, Chi; Stadler, Tanja; Klopfstein, Seraina; Heath, Tracy A; Ronquist, Fredrik

    2016-03-01

    Bayesian total-evidence dating involves the simultaneous analysis of morphological data from the fossil record and morphological and sequence data from recent organisms, and it accommodates the uncertainty in the placement of fossils while dating the phylogenetic tree. Due to the flexibility of the Bayesian approach, total-evidence dating can also incorporate additional sources of information. Here, we take advantage of this and expand the analysis to include information about fossilization and sampling processes. Our work is based on the recently described fossilized birth-death (FBD) process, which has been used to model speciation, extinction, and fossilization rates that can vary over time in a piecewise manner. So far, sampling of extant and fossil taxa has been assumed to be either complete or uniformly at random, an assumption which is only valid for a minority of data sets. We therefore extend the FBD process to accommodate diversified sampling of extant taxa, which is standard practice in studies of higher-level taxa. We verify the implementation using simulations and apply it to the early radiation of Hymenoptera (wasps, ants, and bees). Previous total-evidence dating analyses of this data set were based on a simple uniform tree prior and dated the initial radiation of extant Hymenoptera to the late Carboniferous (309 Ma). The analyses using the FBD prior under diversified sampling, however, date the radiation to the Triassic and Permian (252 Ma), slightly older than the age of the oldest hymenopteran fossils. By exploring a variety of FBD model assumptions, we show that it is mainly the accommodation of diversified sampling that causes the push toward more recent divergence times. Accounting for diversified sampling thus has the potential to close the long-discussed gap between rocks and clocks. We conclude that the explicit modeling of fossilization and sampling processes can improve divergence time estimates, but only if all important model aspects

  9. Extraction of total RNA in the developing chicken forebrain

    Directory of Open Access Journals (Sweden)

    Sayed Rasoul Zaker

    2014-01-01

    Full Text Available Background: Gene expression of Gama-Aminobutyric acid (GABA A receptor subunits may change during development. Procedures in molecular biology are required to understand the gene expression profile GABA A R in chicken. The outcome of the results depends on good-quality high-molecular-weight RNA. Several procedures can be used to isolate RNA from the brain of chicken; however, most of them are time-consuming and require disruption of cells or freeze and thaw in the presence of RNase inhibitors. The aim of this experiment was isolation of RNA from chicken embryonic brain tissues using appropriate RNA extraction kit. Materials and Methods: Fertilized eggs from Ross breed (Gallus gallus were incubated at 38°C and 60% relative humidity in a forced-draft incubator and were turned every 3 h. After 3, 7, 14 and 20 days of incubation, eggs were cooled on ice to induce deep anesthesia. Then whole brains were dissected out. As brains could not be excised in a reproducible way from earlier embryos (embryonic days 4 and 6, whole heads were collected. Chicken embryos between day 7 to 20 and 1 day after birth were decapitated, and their brains removed. Samples were immediately inserted into lysis buffer and stored at −70°C. Total RNA was isolated and a contaminating genomic deoxyribonucleic acid (DNA was digested. RNA quality was checked using gel electrophoresis. Results: We obtained 52 mg/ml to 745 mg/ml with A260/280 1.7-2.2. Only high-quality RNA, with no signs of degradation, was used for further experiments. Conclusion: In conclusion, protocol was found to be suitable for the isolation of total RNA from embryonic chicken cells.

  10. Technical assessment of compliance with workplace air sampling requirements at WRAP

    International Nuclear Information System (INIS)

    HACKWORTH, M.F.

    1999-01-01

    The purpose of this Technical Assessment is to satisfy HSRCM-1, ''Hanford Site Radiological Control Manual'' Article 551.4 for a documented study of facility Workplace Air Monitoring (WAM) programs. HSRCM-1 is the primary guidance for radiological control at Waste Management Federal Services of Hanford, Inc. (WMH). The HSRCM-1 complies with Title 10. Part 835 of the Code of Federal Regulations (10CFR835). This document provides an evaluation of the compliance of the Waste Receiving and Processing facility (WRAP) WAM program to the criteria standards, requirements, and documents compliance with the requirements where appropriate. Where necessary, it also indicates changes needed to bring specific locations into compliance

  11. Water requirement and total body water estimation as affected by species, pregnancy and lactation using tritiated water

    International Nuclear Information System (INIS)

    Kamal, T.H.; El Banna, I.M.; Ayad, M.A.; Kotby, E.A.

    1978-01-01

    Radiotracer dilution technique was used to determine total body water (TBW) and the water turnover rate (WTR) estimate of water requirements in water buffaloe, Red Dannish cattle, fat tailed Osemi sheep and Camellus Dromedarius. Water buffaloes were found to have highest TBW, followed by camels, sheep and cattle in a descending order. The WTR ranking was highest for sheep followed by water buffaloe endurance to heat was found inseperable to high water usage, while in camels, an intericate water retention mechanism help animals to thrive in deserts. Fat tailled Osemi sheep and cattle failed to cope with high environmental temperature resulting in temporary dehydration. TBW was 17% and 6% higher in pregnant cattle and sheep than non-pregnant animals respectively, while there was no observed change in pregnant buffaloes. Water retention of pregnant cattle was associated with an appriciable increase in WTR, which was not noticable in buffaloe or sheep. Lactating buffaloe have had a higher TBW and WTR than lactating cattle. Milk yield per day during the period of measurement was higher in buffalo than cattle. Wallowing of buffalo in water pools during grazing, represents a behavioural adaptation for life in hot regions, aside of tendency for higher WTR with concomitant water retention

  12. Sample Handling Considerations for a Europa Sample Return Mission: An Overview

    Science.gov (United States)

    Fries, M. D.; Calaway, M. L.; Evans, C. A.; McCubbin, F. M.

    2015-01-01

    The intent of this abstract is to provide a basic overview of mission requirements for a generic Europan plume sample return mission, based on NASA Curation experience in NASA sample return missions ranging from Apollo to OSIRIS-REx. This should be useful for mission conception and early stage planning. We will break the mission down into Outbound and Return legs and discuss them separately.

  13. Microfluidic devices for sample clean-up and screening of biological samples

    NARCIS (Netherlands)

    Tetala, K.K.R.

    2009-01-01

    Analytical chemistry plays an important role in the separation and identification of analytes from raw samples (e.g. plant extracts, blood), but the whole analytical process is tedious, difficult to automate and time consuming. To overcome these drawbacks, the concept of μTAS (miniaturized total

  14. Design and device construction for plane tables preparation for counter alpha/beta total; Diseno y construccion de dispositivo para preparacion de planchetas para contador alfa/beta total

    Energy Technology Data Exchange (ETDEWEB)

    Galicia C, F. J.; Monroy G, F., E-mail: fgalicia82@yahoo.com [ININ, Carretera Mexico-Toluca s/n, 52750 Ocoyoacac, Estado de Mexico (Mexico)

    2014-10-15

    This work presents the design and assembly of a device for plane tables preparation for quantification alpha/beta total of radioactive waste samples. The determination of the activity index alpha/beta total is used to detect a wide variety of matrices quickly and the concentration of alpha and/or beta emitters of the contained radionuclides in different samples. In particular, the determination of the activity index alpha and beta total of radioactive wastes involves the digestion of samples in aggressive means that will be evaporated to dryness for its quantification. With the purpose of controlling the emission of corrosive gases during the preparation of the plane tables for the quantification of the index alpha and beta total, was designed and built the device in the Radioactive Waste Laboratory that allows to prepare plane tables for proportional counters in a sure and efficient way. The device is constituted by heating equipment, evaporation cylinder and a gases cleaning system. The self-absorption curve got ready starting from the device. (Author)

  15. A modified gelatin zymography technique incorporating total protein normalization.

    Science.gov (United States)

    Raykin, Julia; Snider, Eric; Bheri, Sruti; Mulvihill, John; Ethier, C Ross

    2017-03-15

    Gelatinase zymography is a commonly used laboratory procedure; however, variability in sample loading and concentration reduce the accuracy of quantitative results obtained from this technique. To facilitate normalization of gelatinase activity by loaded protein amount, we developed a protocol using the trihalocompound 2,2,2-trichloroethanol to allow for gelatin zymography and total protein labeling within the same gel. We showed that detected protein levels increased linearly with loading, and describe a loading concentration range over which normalized gelatinase activity was constant. We conclude that in-gel total protein detection is feasible in gelatin zymography and greatly improves comparison of gelatinase activity between samples. Published by Elsevier Inc.

  16. Improved sample size determination for attributes and variables sampling

    International Nuclear Information System (INIS)

    Stirpe, D.; Picard, R.R.

    1985-01-01

    Earlier INMM papers have addressed the attributes/variables problem and, under conservative/limiting approximations, have reported analytical solutions for the attributes and variables sample sizes. Through computer simulation of this problem, we have calculated attributes and variables sample sizes as a function of falsification, measurement uncertainties, and required detection probability without using approximations. Using realistic assumptions for uncertainty parameters of measurement, the simulation results support the conclusions: (1) previously used conservative approximations can be expensive because they lead to larger sample sizes than needed; and (2) the optimal verification strategy, as well as the falsification strategy, are highly dependent on the underlying uncertainty parameters of the measurement instruments. 1 ref., 3 figs

  17. Total dissolved carbohydrate in Mahi river estuary

    Digital Repository Service at National Institute of Oceanography (India)

    Bhosle, N.B.; Rokade, M.A.; Zingde, M.D.

    Total dissolved carbohydrate varied from 4.37-15 mg l-1 and 3.71-15.95 mg l-1 in the surface and bottom samples respectively. Highest concentration of carbohydrate was observed at station 1 which decreased downward upto Station 6 which showed...

  18. Correlation of total, diffuse, and direct solar radiation

    Science.gov (United States)

    Buyco, E. H.; Namkoong, D.

    1977-01-01

    Present requirements for realistic solar energy system evaluations necessitate a comprehensive body of solar-radition data. The data should include both diffuse and direct solar radiation as well as their total on an hourly (or shorter) basis. In general, however, only the total solar radiation values were recorded. This report presents a correlation that relates the diffuse component of an hourly total solar radiation value to the total radiation ratio of the maximum value attainable. The data used were taken at the Blue Hill Observatory in Milton, Massachusetts, for the period 1952. The relation - in the form of the data plots - can be used in situations in which only the hourly total radiation data are available but the diffuse component is desired.

  19. Sample size requirements for studies of treatment effects on beta-cell function in newly diagnosed type 1 diabetes.

    Science.gov (United States)

    Lachin, John M; McGee, Paula L; Greenbaum, Carla J; Palmer, Jerry; Pescovitz, Mark D; Gottlieb, Peter; Skyler, Jay

    2011-01-01

    Preservation of β-cell function as measured by stimulated C-peptide has recently been accepted as a therapeutic target for subjects with newly diagnosed type 1 diabetes. In recently completed studies conducted by the Type 1 Diabetes Trial Network (TrialNet), repeated 2-hour Mixed Meal Tolerance Tests (MMTT) were obtained for up to 24 months from 156 subjects with up to 3 months duration of type 1 diabetes at the time of study enrollment. These data provide the information needed to more accurately determine the sample size needed for future studies of the effects of new agents on the 2-hour area under the curve (AUC) of the C-peptide values. The natural log(x), log(x+1) and square-root (√x) transformations of the AUC were assessed. In general, a transformation of the data is needed to better satisfy the normality assumptions for commonly used statistical tests. Statistical analysis of the raw and transformed data are provided to estimate the mean levels over time and the residual variation in untreated subjects that allow sample size calculations for future studies at either 12 or 24 months of follow-up and among children 8-12 years of age, adolescents (13-17 years) and adults (18+ years). The sample size needed to detect a given relative (percentage) difference with treatment versus control is greater at 24 months than at 12 months of follow-up, and differs among age categories. Owing to greater residual variation among those 13-17 years of age, a larger sample size is required for this age group. Methods are also described for assessment of sample size for mixtures of subjects among the age categories. Statistical expressions are presented for the presentation of analyses of log(x+1) and √x transformed values in terms of the original units of measurement (pmol/ml). Analyses using different transformations are described for the TrialNet study of masked anti-CD20 (rituximab) versus masked placebo. These results provide the information needed to accurately

  20. Sample size requirements for studies of treatment effects on beta-cell function in newly diagnosed type 1 diabetes.

    Directory of Open Access Journals (Sweden)

    John M Lachin

    Full Text Available Preservation of β-cell function as measured by stimulated C-peptide has recently been accepted as a therapeutic target for subjects with newly diagnosed type 1 diabetes. In recently completed studies conducted by the Type 1 Diabetes Trial Network (TrialNet, repeated 2-hour Mixed Meal Tolerance Tests (MMTT were obtained for up to 24 months from 156 subjects with up to 3 months duration of type 1 diabetes at the time of study enrollment. These data provide the information needed to more accurately determine the sample size needed for future studies of the effects of new agents on the 2-hour area under the curve (AUC of the C-peptide values. The natural log(x, log(x+1 and square-root (√x transformations of the AUC were assessed. In general, a transformation of the data is needed to better satisfy the normality assumptions for commonly used statistical tests. Statistical analysis of the raw and transformed data are provided to estimate the mean levels over time and the residual variation in untreated subjects that allow sample size calculations for future studies at either 12 or 24 months of follow-up and among children 8-12 years of age, adolescents (13-17 years and adults (18+ years. The sample size needed to detect a given relative (percentage difference with treatment versus control is greater at 24 months than at 12 months of follow-up, and differs among age categories. Owing to greater residual variation among those 13-17 years of age, a larger sample size is required for this age group. Methods are also described for assessment of sample size for mixtures of subjects among the age categories. Statistical expressions are presented for the presentation of analyses of log(x+1 and √x transformed values in terms of the original units of measurement (pmol/ml. Analyses using different transformations are described for the TrialNet study of masked anti-CD20 (rituximab versus masked placebo. These results provide the information needed to

  1. Rapid Surface Sampling and Archival Record (RSSAR) system. Final report, October 1995 - May 1997

    International Nuclear Information System (INIS)

    1998-01-01

    This report describes the results of Phase 2 efforts to develop a Rapid Surface Sampling and Archival Record (RSSAR) System for the detection of semivolatile organic contaminants on concrete, transite, and metal surfaces. The characterization of equipment and building surfaces for the presence of contaminants as part of building decontamination and decommissioning activities is an immensely large task of concern to both government and industry. Because of the high cost of hazardous waste disposal, old, contaminated buildings cannot simply be demolished and scrapped. Contaminated and clean materials must be clearly identified and segregated so that the clean material can be recycled or reused, if possible, or disposed of more cheaply as nonhazardous waste. DOE has a number of sites requiring surface characterization. These sites are large, contain very heterogeneous patterns of contamination (requiring high sampling density), and will thus necessitate an enormous number of samples to be taken and analyzed. Characterization of building and equipment surfaces will be needed during initial investigations, during cleanup operations, and during the final confirmation process, increasing the total number of samples well beyond that needed for initial characterization. This multiplicity of information places a premium on the ability to handle and track data as efficiently as possible

  2. Rapid Surface Sampling and Archival Record (RSSAR) system. Final report, October 1995--May 1997

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-12-31

    This report describes the results of Phase 2 efforts to develop a Rapid Surface Sampling and Archival Record (RSSAR) System for the detection of semivolatile organic contaminants on concrete, transite, and metal surfaces. The characterization of equipment and building surfaces for the presence of contaminants as part of building decontamination and decommissioning activities is an immensely large task of concern to both government and industry. Because of the high cost of hazardous waste disposal, old, contaminated buildings cannot simply be demolished and scrapped. Contaminated and clean materials must be clearly identified and segregated so that the clean material can be recycled or reused, if possible, or disposed of more cheaply as nonhazardous waste. DOE has a number of sites requiring surface characterization. These sites are large, contain very heterogeneous patterns of contamination (requiring high sampling density), and will thus necessitate an enormous number of samples to be taken and analyzed. Characterization of building and equipment surfaces will be needed during initial investigations, during cleanup operations, and during the final confirmation process, increasing the total number of samples well beyond that needed for initial characterization. This multiplicity of information places a premium on the ability to handle and track data as efficiently as possible.

  3. 40 CFR 761.323 - Sample preparation.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 30 2010-07-01 2010-07-01 false Sample preparation. 761.323 Section... Remediation Waste Samples § 761.323 Sample preparation. (a) The comparison study requires analysis of a... concentrations by dilution. Any excess material resulting from the preparation of these samples, which is not...

  4. Sample Return Robot

    Data.gov (United States)

    National Aeronautics and Space Administration — This Challenge requires demonstration of an autonomous robotic system to locate and collect a set of specific sample types from a large planetary analog area and...

  5. The use of adaptive equipment following total knee replacement

    OpenAIRE

    McNaught, Jamie; Paul, Lorna

    2015-01-01

    Introduction: This study evaluates the need for adaptive equipment following total knee replacement. There are no recent studies to guide occupational therapists in the optimum time adaptive equipment is required following total knee replacement.\\ud \\ud Method: A non-experimental, concurrent mixed methods approach was used. The study population was patients attending for total knee replacement at a large general hospital. Outcome measures were the Oxford Knee Score, the United Kingdom Functio...

  6. Thermal probe design for Europa sample acquisition

    Science.gov (United States)

    Horne, Mera F.

    2018-01-01

    The planned lander missions to the surface of Europa will access samples from the subsurface of the ice in a search for signs of life. A small thermal drill (probe) is proposed to meet the sample requirement of the Science Definition Team's (SDT) report for the Europa mission. The probe is 2 cm in diameter and 16 cm in length and is designed to access the subsurface to 10 cm deep and to collect five ice samples of 7 cm3 each, approximately. The energy required to penetrate the top 10 cm of ice in a vacuum is 26 Wh, approximately, and to melt 7 cm3 of ice is 1.2 Wh, approximately. The requirement stated in the SDT report of collecting samples from five different sites can be accommodated with repeated use of the same thermal drill. For smaller sample sizes, a smaller probe of 1.0 cm in diameter with the same length of 16 cm could be utilized that would require approximately 6.4 Wh to penetrate the top 10 cm of ice, and 0.02 Wh to collect 0.1 g of sample. The thermal drill has the advantage of simplicity of design and operations and the ability to penetrate ice over a range of densities and hardness while maintaining sample integrity.

  7. Equipment for collecting samples of radioactive solutions

    International Nuclear Information System (INIS)

    Raggenbass, A.; Fradin, J.; Joubert, G.

    1958-01-01

    The authors present an equipment aimed at collecting samples of fission products to perform radio-chemical analysis. As the sample must have a total activity between 1 and 50 micro-Curie, this installation comprises a sampling system and a dilution device which aims at bringing the sample to the suitable activity. Samples are collected by means of needles. The sample reproducibility is discussed. The dilution device is described

  8. A Comparison of Concentrations of Sodium and Related Nutrients (Potassium, Total Dietary Fiber, Total and Saturated Fat, and Total Sugar) in Private-Label and National Brands of Popular, Sodium-Contributing, Commercially Packaged Foods in the United States.

    Science.gov (United States)

    Ahuja, Jaspreet K C; Pehrsson, Pamela R; Cogswell, Mary

    2017-05-01

    Private-label brands account for about one in four foods sold in US supermarkets. They provide value to consumers due to their low cost. We know of no US studies comparing the nutrition content of private-label products with corresponding national brand products. The objective was to compare concentrations of sodium and related nutrients (potassium, total dietary fiber, total and saturated fat, and total sugar) in popular sodium-contributing, commercially packaged foods by brand type (national or private-label brand). During 2010 to 2014, the Nutrient Data Laboratory of the US Department of Agriculture obtained 1,706 samples of private-label and national brand products from up to 12 locations nationwide and chemically analyzed 937 composites for sodium and related nutrients. The samples came from 61 sodium-contributing, commercially packaged food products for which both private-label and national brands were among the top 75% to 80% of brands for US unit sales. In this post hoc comparative analysis, the authors assigned a variable brand type (national or private label) to each composite and determined mean nutrient contents by brand type overall and by food product and type. The authors tested for significant differences (Pfoods sampled, differences between brand types were not statistically significant for any of the nutrients studied. However, differences in both directions exist for a few individual food products and food categories. Concentrations of sodium and related nutrients (potassium, total dietary fiber, total and saturated fat, and total sugar) do not differ systematically between private-label and national brands, suggesting that brand type is not a consideration for nutritional quality of foods in the United States. The study data provide public health officials with baseline nutrient content by brand type to help focus US sodium-reduction efforts. Published by Elsevier Inc.

  9. 'Intelligent' approach to radioimmunoassay sample counting employing a microprocessor controlled sample counter

    International Nuclear Information System (INIS)

    Ekins, R.P.; Sufi, S.; Malan, P.G.

    1977-01-01

    The enormous impact on medical science in the last two decades of microanalytical techniques employing radioisotopic labels has, in turn, generated a large demand for automatic radioisotopic sample counters. Such instruments frequently comprise the most important item of capital equipment required in the use of radioimmunoassay and related techniques and often form a principle bottleneck in the flow of samples through a busy laboratory. It is therefore particularly imperitive that such instruments should be used 'intelligently' and in an optimal fashion to avoid both the very large capital expenditure involved in the unnecessary proliferation of instruments and the time delays arising from their sub-optimal use. The majority of the current generation of radioactive sample counters nevertheless rely on primitive control mechanisms based on a simplistic statistical theory of radioactive sample counting which preclude their efficient and rational use. The fundamental principle upon which this approach is based is that it is useless to continue counting a radioactive sample for a time longer than that required to yield a significant increase in precision of the measurement. Thus, since substantial experimental errors occur during sample preparation, these errors should be assessed and must be releted to the counting errors for that sample. It is the objective of this presentation to demonstrate that the combination of a realistic statistical assessment of radioactive sample measurement, together with the more sophisticated control mechanisms that modern microprocessor technology make possible, may often enable savings in counter usage of the order of 5-10 fold to be made. (orig.) [de

  10. Small sample whole-genome amplification

    Science.gov (United States)

    Hara, Christine; Nguyen, Christine; Wheeler, Elizabeth; Sorensen, Karen; Arroyo, Erin; Vrankovich, Greg; Christian, Allen

    2005-11-01

    Many challenges arise when trying to amplify and analyze human samples collected in the field due to limitations in sample quantity, and contamination of the starting material. Tests such as DNA fingerprinting and mitochondrial typing require a certain sample size and are carried out in large volume reactions; in cases where insufficient sample is present whole genome amplification (WGA) can be used. WGA allows very small quantities of DNA to be amplified in a way that enables subsequent DNA-based tests to be performed. A limiting step to WGA is sample preparation. To minimize the necessary sample size, we have developed two modifications of WGA: the first allows for an increase in amplified product from small, nanoscale, purified samples with the use of carrier DNA while the second is a single-step method for cleaning and amplifying samples all in one column. Conventional DNA cleanup involves binding the DNA to silica, washing away impurities, and then releasing the DNA for subsequent testing. We have eliminated losses associated with incomplete sample release, thereby decreasing the required amount of starting template for DNA testing. Both techniques address the limitations of sample size by providing ample copies of genomic samples. Carrier DNA, included in our WGA reactions, can be used when amplifying samples with the standard purification method, or can be used in conjunction with our single-step DNA purification technique to potentially further decrease the amount of starting sample necessary for future forensic DNA-based assays.

  11. Older patients can accurately recall their preoperative health status six weeks following total hip arthroplasty.

    Science.gov (United States)

    Marsh, Jackie; Bryant, Dianne; MacDonald, Steven J

    2009-12-01

    In clinical trials, use of patient recall data would be beneficial when the collection of baseline data is impossible, such as in trauma situations. We investigated the ability of older patients to accurately recall their preoperative quality of life, function, and general health status at six weeks following total hip arthroplasty. We randomized consecutive patients who were fifty-five years of age or older into two groups. At each assessment, patients completed self-report questionnaires (at four weeks preoperatively, on the day of surgery, and at six weeks and three months postoperatively for Group 1 and at six weeks and three months postoperatively for Group 2). At six weeks postoperatively, all patients completed the questionnaires on the basis of their recollection of their preoperative health status. We evaluated the validity and reliability of recall ratings, the degree of error in recall ratings, and the effects of the use of recall data on power and sample size requirements. A total of 174 patients (mean age, seventy-one years) who were undergoing either primary or revision total hip arthroplasty were randomized and included in the analysis (118 patients were in Group 1 and fifty-six were in Group 2). Agreement between actual and recalled data was excellent for disease-specific questionnaires (intraclass correlation coefficient, 0.86, 0.87, and 0.88) and moderate for generic health measures (intraclass correlation coefficient, 0.48, 0.58, and 0.60). Increased error associated with recalled ratings compared with actual ratings necessitates minimal increases in sample size or results in small decreases in power. Patients undergoing total hip arthroplasty can accurately recall their preoperative health status at six weeks postoperatively.

  12. 45-day safety screen results and final report for tank 241-C-202, auger samples 95-Aug-026 and 95-Aug-027

    International Nuclear Information System (INIS)

    Baldwin, J.H.

    1995-01-01

    Two auger samples from tank 241-C-202 (C-202) were received at the 222-S Laboratories and underwent safety screening analysis, consisting of differential scanning calorimetry (DSC), thermogravimetric analysis (TGA), and total alpha activity. Two samples were submitted for energetics determination by DSC. Within the triplicate analyses of each sample, one of the results for energetics exceeded the notification limit. The sample and duplicate analyses for both augers exceeded the notification limit for TGA. As required by the Tank Characterization Plan, the appropriate notifications were made within 24 hours of official confirmation that the limits were violated

  13. Total reflection X-ray fluorescence analysis

    International Nuclear Information System (INIS)

    Michaelis, W.; Prange, A.

    1987-01-01

    In the past few years, total reflection X-ray flourescence analysis (TXRF) has found an increasing number of assignments and applications. Experience of trace element analysis using TXRF and examples of applications are already widespread. Therefore, users of TXRF had the opportunity of an intensive exchange of their experience at the 1st workshop on total reflection X-ray fluorescence analysis which took place on May 27th and 28th 1986 at the GKSS Research Centre at Geesthacht. In a series of lectures and discussions dealing with the analytical principle itself, sample preparation techniques and applications as well as comuter programs for spectrum evaluation, the present state of development and the range of applications were outlined. 3 studies out of a total of 14 were included separately in the INIS and ENERGY databases. With 61 figs., 12 tabs [de

  14. NG09 And CTBT On-Site Inspection Noble Gas Sampling and Analysis Requirements

    Science.gov (United States)

    Carrigan, Charles R.; Tanaka, Junichi

    2010-05-01

    A provision of the Comprehensive Test Ban Treaty (CTBT) allows on-site inspections (OSIs) of suspect nuclear sites to determine if the occurrence of a detected event is nuclear in origin. For an underground nuclear explosion (UNE), the potential success of an OSI depends significantly on the containment scenario of the alleged event as well as the application of air and soil-gas radionuclide sampling techniques in a manner that takes into account both the suspect site geology and the gas transport physics. UNE scenarios may be broadly divided into categories involving the level of containment. The simplest to detect is a UNE that vents a significant portion of its radionuclide inventory and is readily detectable at distance by the International Monitoring System (IMS). The most well contained subsurface events will only be detectable during an OSI. In such cases, 37 Ar and radioactive xenon cavity gases may reach the surface through either "micro-seepage" or the barometric pumping process and only the careful siting of sampling locations, timing of sampling and application of the most site-appropriate atmospheric and soil-gas capturing methods will result in a confirmatory signal. The OSI noble gas field tests NG09 was recently held in Stupava, Slovakia to consider, in addition to other field sampling and analysis techniques, drilling and subsurface noble gas extraction methods that might be applied during an OSI. One of the experiments focused on challenges to soil-gas sampling near the soil-atmosphere interface. During withdrawal of soil gas from shallow, subsurface sample points, atmospheric dilution of the sample and the potential for introduction of unwanted atmospheric gases were considered. Tests were designed to evaluate surface infiltration and the ability of inflatable well-packers to seal out atmospheric gases during sample acquisition. We discuss these tests along with some model-based predictions regarding infiltration under different near

  15. Flow analysis methods for the direct ultra-violet spectrophotometric measurement of nitrate and total nitrogen in freshwaters

    Energy Technology Data Exchange (ETDEWEB)

    Gentle, Brady S.; Ellis, Peter S.; Grace, Michael R. [Water Studies Centre, School of Chemistry, Monash University, Victoria 3800 (Australia); McKelvie, Ian D., E-mail: iandm@unimelb.edu.au [School of Chemistry, University of Melbourne, Victoria 3010 (Australia); School of Geography, Earth and Environmental Sciences, University of Plymouth, Drake Circus, Plymouth PL4 8AA (United Kingdom)

    2011-10-17

    Highlights: {yields} Second derivative UV spectrophotometry has been used to determine nitrate and total N using flow analysis techniques. {yields} A simple flow system with a single-reflection flow-through cell was used for the UV measurement of nitrate. {yields} Total N was determined after on-line UV photooxidation with alkaline peroxodisulfate. {yields} Analyses carried out using the developed flow systems show a high degree of agreement with comparative analyses. {yields} This method requires no colorimetric reagents and eliminates the requirement for a toxic cadmium reduction column. - Abstract: Second derivative ultra-violet spectrophotometric methods are described for the measurement of nitrate and total nitrogen in freshwaters using flow analysis techniques. A simple flow system consisting of a peristaltic pump and a single-reflection flow-through cell was used for the measurement of nitrate. Quantification of total nitrogen using alkaline peroxodisulfate photo-digestion was achieved by incorporating an ultra-violet photo-reactor, a hollow-fibre filter and a debubbler into the flow system. The nitrate system featured a limit of detection of 0.04 mg N L{sup -1}, 0.4%RSD (1 mg N L{sup -1} as nitrate, n = 10), a coefficient of determination (R{sup 2}) of 0.9995 over the calibration range 0.0-2.0 mg N L{sup -1}, and a data acquisition time of 1.5 s per spectrum. The total nitrogen system featured a limit of detection of 0.05 mg N L{sup -1}, 1%RSD (1 mg N L{sup -1} as ammonium chloride, n = 10), a coefficient of determination of 0.9989 over the calibration range 0.0-2.0 mg N L{sup -1}, and a throughput of 5 sample h{sup -1} measured in triplicate. Digestions of five model nitrogen compounds returned recoveries of >88%. Determinations carried out using the developed systems show a high degree of agreement with data obtained using reference methods. These methods require no colorimetric reagents and eliminate the requirement for a toxic cadmium reduction column

  16. Flow analysis methods for the direct ultra-violet spectrophotometric measurement of nitrate and total nitrogen in freshwaters

    International Nuclear Information System (INIS)

    Gentle, Brady S.; Ellis, Peter S.; Grace, Michael R.; McKelvie, Ian D.

    2011-01-01

    Highlights: → Second derivative UV spectrophotometry has been used to determine nitrate and total N using flow analysis techniques. → A simple flow system with a single-reflection flow-through cell was used for the UV measurement of nitrate. → Total N was determined after on-line UV photooxidation with alkaline peroxodisulfate. → Analyses carried out using the developed flow systems show a high degree of agreement with comparative analyses. → This method requires no colorimetric reagents and eliminates the requirement for a toxic cadmium reduction column. - Abstract: Second derivative ultra-violet spectrophotometric methods are described for the measurement of nitrate and total nitrogen in freshwaters using flow analysis techniques. A simple flow system consisting of a peristaltic pump and a single-reflection flow-through cell was used for the measurement of nitrate. Quantification of total nitrogen using alkaline peroxodisulfate photo-digestion was achieved by incorporating an ultra-violet photo-reactor, a hollow-fibre filter and a debubbler into the flow system. The nitrate system featured a limit of detection of 0.04 mg N L -1 , 0.4%RSD (1 mg N L -1 as nitrate, n = 10), a coefficient of determination (R 2 ) of 0.9995 over the calibration range 0.0-2.0 mg N L -1 , and a data acquisition time of 1.5 s per spectrum. The total nitrogen system featured a limit of detection of 0.05 mg N L -1 , 1%RSD (1 mg N L -1 as ammonium chloride, n = 10), a coefficient of determination of 0.9989 over the calibration range 0.0-2.0 mg N L -1 , and a throughput of 5 sample h -1 measured in triplicate. Digestions of five model nitrogen compounds returned recoveries of >88%. Determinations carried out using the developed systems show a high degree of agreement with data obtained using reference methods. These methods require no colorimetric reagents and eliminate the requirement for a toxic cadmium reduction column. The overlap of chloride and nitrate spectra in seawater is

  17. Environmental surveillance master sampling schedule

    International Nuclear Information System (INIS)

    Bisping, L.E.

    1991-01-01

    Environmental surveillance of the Hanford Site and surrounding areas is conducted by the Pacific Northwest Laboratory (PNL) for the US Department of Energy (DOE). This document contains the planned schedule for routine sample collection for the Surface Environmental Surveillance Project (SESP) and Ground-Water Monitoring Project. The routine sampling plan for the SESP has been revised this year to reflect changing site operations and priorities. Some sampling previously performed at least annually has been reduced in frequency, and some new sampling to be performed at a less than annual frequency has been added. Therefore, the SESP schedule reflects sampling to be conducted in calendar year 1991 as well as future years. The ground-water sampling schedule is for 1991. This schedule is subject to modification during the year in response to changes in Site operation, program requirements, and the nature of the observed results. Operational limitations such as weather, mechanical failures, sample availability, etc., may also require schedule modifications. Changes will be documented in the respective project files, but this plan will not be reissued. The purpose of these monitoring projects is to evaluate levels of radioactive and nonradioactive pollutants in the Hanford evirons

  18. Environmental surveillance master sampling schedule

    Energy Technology Data Exchange (ETDEWEB)

    Bisping, L.E.

    1991-01-01

    Environmental surveillance of the Hanford Site and surrounding areas is conducted by the Pacific Northwest Laboratory (PNL) for the US Department of Energy (DOE). This document contains the planned schedule for routine sample collection for the Surface Environmental Surveillance Project (SESP) and Ground-Water Monitoring Project. The routine sampling plan for the SESP has been revised this year to reflect changing site operations and priorities. Some sampling previously performed at least annually has been reduced in frequency, and some new sampling to be performed at a less than annual frequency has been added. Therefore, the SESP schedule reflects sampling to be conducted in calendar year 1991 as well as future years. The ground-water sampling schedule is for 1991. This schedule is subject to modification during the year in response to changes in Site operation, program requirements, and the nature of the observed results. Operational limitations such as weather, mechanical failures, sample availability, etc., may also require schedule modifications. Changes will be documented in the respective project files, but this plan will not be reissued. The purpose of these monitoring projects is to evaluate levels of radioactive and nonradioactive pollutants in the Hanford evirons.

  19. Mortality After Total Knee and Total Hip Arthroplasty in a Large Integrated Health Care System.

    Science.gov (United States)

    Inacio, Maria C S; Dillon, Mark T; Miric, Alex; Navarro, Ronald A; Paxton, Elizabeth W

    2017-01-01

    The number of excess deaths associated with elective total joint arthroplasty in the US is not well understood. To evaluate one-year postoperative mortality among patients with elective primary and revision arthroplasty procedures of the hip and knee. A retrospective analysis was conducted of hip and knee arthroplasties performed in 2010. Procedure type, procedure volume, patient age and sex, and mortality were obtained from an institutional total joint replacement registry. An integrated health care system population was the sampling frame for the study subjects and was the reference group for the study. Standardized 1-year mortality ratios (SMRs) and 95% confidence intervals (CIs) were calculated. A total of 10,163 primary total knee arthroplasties (TKAs), 4963 primary total hip arthroplasties (THAs), 606 revision TKAs, and 496 revision THAs were evaluated. Patients undergoing primary THA (SMR = 0.6, 95% CI = 0.4-0.7) and TKA (SMR = 0.4, 95% CI = 0.3-0.5) had lower odds of mortality than expected. Patients with revision TKA had higher-than-expected mortality odds (SMR = 1.8, 95% CI = 1.1-2.5), whereas patients with revision THA (SMR = 0.9, 95% CI = 0.4-1.5) did not have higher-than-expected odds of mortality. Understanding excess mortality after joint surgery allows clinicians to evaluate current practices and to determine whether certain groups are at higher-than-expected mortality risk after surgery.

  20. Geographical differences in the relationship between total dissolved ...

    African Journals Online (AJOL)

    on the Department of Water Affairs water quality database. ... Keywords: conversion factors, electrical conductivity, field instruments, rivers, total dissolved solids, water quality ... of a number of TDS:EC ratios in samples where both measure-.

  1. Improved sample preparation and counting techniques for enhanced tritium measurement sensitivity

    Science.gov (United States)

    Moran, J.; Aalseth, C.; Bailey, V. L.; Mace, E. K.; Overman, C.; Seifert, A.; Wilcox Freeburg, E. D.

    2015-12-01

    Tritium (T) measurements offer insight to a wealth of environmental applications including hydrologic tracking, discerning ocean circulation patterns, and aging ice formations. However, the relatively short half-life of T (12.3 years) limits its effective age dating range. Compounding this limitation is the decrease in atmospheric T content by over two orders of magnitude (from 1000-2000 TU in 1962 to testing in the 1960's. We are developing sample preparation methods coupled to direct counting of T via ultra-low background proportional counters which, when combined, offer improved T measurement sensitivity (~4.5 mmoles of H2 equivalent) and will help expand the application of T age dating to smaller sample sizes linked to persistent environmental questions despite the limitations above. For instance, this approach can be used to T date ~ 2.2 mmoles of CH4 collected from sample-limited systems including microbial communities, soils, or subsurface aquifers and can be combined with radiocarbon dating to distinguish the methane's formation age from C age in a system. This approach can also expand investigations into soil organic C where the improved sensitivity will permit resolution of soil C into more descriptive fractions and provide direct assessments of the stability of specific classes of organic matter in soils environments. We are employing a multiple step sample preparation system whereby organic samples are first combusted with resulting CO2 and H2O being used as a feedstock to synthesize CH4. This CH4 is mixed with Ar and loaded directly into an ultra-low background proportional counter for measurement of T β decay in a shallow underground laboratory. Analysis of water samples requires only the addition of geologic CO2 feedstock with the sample for methane synthesis. The chemical nature of the preparation techniques enable high sample throughput with only the final measurement requiring T decay with total sample analysis time ranging from 2 -5 weeks

  2. Enhanced AFCI Sampling, Analysis, and Safeguards Technology Review

    Energy Technology Data Exchange (ETDEWEB)

    John Svoboda

    2009-09-01

    The focus of this study includes the investigation of sampling technologies used in industry and their potential application to nuclear fuel processing. The goal is to identify innovative sampling methods using state of the art techniques that could evolve into the next generation sampling and analysis system for metallic elements. Sampling and analysis of nuclear fuel recycling plant processes is required both to monitor the operations and ensure Safeguards and Security goals are met. In addition, environmental regulations lead to additional samples and analysis to meet licensing requirements. The volume of samples taken by conventional means, can restrain productivity while results samples are analyzed, require process holding tanks that are sized to meet analytical issues rather than process issues (and that create a larger facility footprint), or, in some cases, simply overwhelm analytical laboratory capabilities. These issues only grow when process flowsheets propose new separations systems and new byproduct material for transmutation purposes. Novel means of streamlining both sampling and analysis are being evaluated to increase the efficiency while meeting all requirements for information. This report addresses just a part of the effort to develop and study novel methods by focusing on the sampling and analysis of aqueous samples for metallic elements. It presents an overview of the sampling requirements, including frequency, sensitivity, accuracy, and programmatic drivers, to demonstrate the magnitude of the task. The sampling and analysis system needed for metallic element measurements is then discussed, and novel options being applied to other industrial analytical needs are presented. Inductively coupled mass spectrometry instruments are the most versatile for metallic element analyses and are thus chosen as the focus for the study. Candidate novel means of process sampling, as well as modifications that are necessary to couple such instruments to

  3. NASA Construction of Facilities Validation Processes - Total Building Commissioning (TBCx)

    Science.gov (United States)

    Hoover, Jay C.

    2004-01-01

    Key Atributes include: Total Quality Management (TQM) System that looks at all phases of a project. A team process that spans boundaries. A Commissioning Authority to lead the process. Commissioning requirements in contracts. Independent design review to verify compliance with Facility Project Requirements (FPR). Formal written Commissioning Plan with Documented Results. Functional performance testing (FPT) against the requirements document.

  4. Automated combustion accelerator mass spectrometry for the analysis of biomedical samples in the low attomole range.

    Science.gov (United States)

    van Duijn, Esther; Sandman, Hugo; Grossouw, Dimitri; Mocking, Johannes A J; Coulier, Leon; Vaes, Wouter H J

    2014-08-05

    The increasing role of accelerator mass spectrometry (AMS) in biomedical research necessitates modernization of the traditional sample handling process. AMS was originally developed and used for carbon dating, therefore focusing on a very high precision but with a comparably low sample throughput. Here, we describe the combination of automated sample combustion with an elemental analyzer (EA) online coupled to an AMS via a dedicated interface. This setup allows direct radiocarbon measurements for over 70 samples daily by AMS. No sample processing is required apart from the pipetting of the sample into a tin foil cup, which is placed in the carousel of the EA. In our system, up to 200 AMS analyses are performed automatically without the need for manual interventions. We present results on the direct total (14)C count measurements in <2 μL human plasma samples. The method shows linearity over a range of 0.65-821 mBq/mL, with a lower limit of quantification of 0.65 mBq/mL (corresponding to 0.67 amol for acetaminophen). At these extremely low levels of activity, it becomes important to quantify plasma specific carbon percentages. This carbon percentage is automatically generated upon combustion of a sample on the EA. Apparent advantages of the present approach include complete omission of sample preparation (reduced hands-on time) and fully automated sample analysis. These improvements clearly stimulate the standard incorporation of microtracer research in the drug development process. In combination with the particularly low sample volumes required and extreme sensitivity, AMS strongly improves its position as a bioanalysis method.

  5. ANALISIS DIMENSI KUALITAS PELAYANAN TERHADAP KEPUASAN MELALUI TOTAL QUALITY EDUCATION SEBAGAI MEDIATOR

    Directory of Open Access Journals (Sweden)

    Laela Atikah

    2017-10-01

    Full Text Available The purpose of this research is to know the effect of reliability, responsiveness, tangible, empathy, and assurance to student satisfaction through Total Quality Education as mediator variable. Population in this research is students of Universitas Negeri Semarang academic year 2015. Sampling used proportional random sampling with numbers of respondents more 395. Methods of data collection used questionnaires. Analysis methods were partial test and path analysis. The results showed that reliability, responsiveness, empathy, and assurance have positive and significant effect on student satisfaction with significance value 0,05. Reliability has a positive and significant impact on satisfaction through Total Quality Education with total influence of 0,121. Responsiveness has a positive and significant impact on satisfaction through Total Quality Education with total influence of 0,126. Tangible has a positive and significant impact on satisfaction through Total Quality Education with total influence of 0,130. Empathy has a positive and significant impact on satisfaction through Total Quality Education with total influence of 0,272. Assurance has a positive and significant impact on satisfaction through Total Quality Education with total influence of 0,250. It is can be concluced that Total Quality Education is a role as an intervening variable between reliability, responsivenesss, tangible, empathy, and assurance of student satisfaction.

  6. Sampling and analysis plan (SAP) for WESF drains and TK-100 sump

    International Nuclear Information System (INIS)

    Simmons, F.M.

    1998-01-01

    The intent of this project is to determine whether the Waste Encapsulation and Storage Facility (WESF) floor drain piping and the TK-100 sump are free from contamination. TK-100 is currently used as a catch tank to transfer low level liquid waste from WESF to Tank Farms via B Plant. This system is being modified as part of the WESF decoupling since B Plant is being deactivated. As a result of the 1,1,1-trichloroethane (TCA) discovery in TK-100, the associated WESF floor drains and the pit sump need to be sampled. Breakdown constituents have been reviewed and found to be non-hazardous. There are 29 floor drains that tie into a common header leading into the tank. To prevent high exposure during sampling of the drains, TK-100 will be removed into the B Plant canyon and a new tank will be placed in the pit before any floor drain samples are taken. The sump will be sampled prior to TK-100 removal. A sample of the sludge and any liquid in the sump will be taken and analyzed for TCA and polychlorinated biphenyl (PCB). After the sump has been sampled, the vault floor will be flushed. The flush will be transferred from the sump into TK-100. TK-100 will be moved into B Plant. The vault will then be cleaned of debris and visually inspected. If there is no visual indication of TCA or PCB staining, the vault will be painted and a new tank installed. If there is an indication of TCA or PCB from laboratory analysis or staining, further negotiations will be required to determine a path forward. A total of 8 sets of three 40ml samples will be required for all of the floor drains and sump. The sump set will include one 125ml solid sample. The only analysis required will be for TCA in liquids. PCBs will be checked in sump solids only. The Sampling and Analysis Plan (SAP) is written to provide direction for the sampling and analytical activities of the 29 WESF floor drains and the TK-100 sump. The intent of this plan is to define the responsibilities of the various organizations

  7. Technology Development and Advanced Planning for Curation of Returned Mars Samples

    Science.gov (United States)

    Lindstrom, David J.; Allen, Carlton C.

    2002-01-01

    Safety Level 4) laboratories, while simultaneously maintaining cleanliness levels equaling those of state-of-the-art cleanrooms. Unique requirements for the processing of Mars samples have inspired a program to develop handling techniques that are much more precise and reliable than the approach (currently used for lunar samples) of employing gloved human hands in nitrogen-filled gloveboxes. Individual samples from Mars are expected to be much smaller than lunar samples, the total mass of samples returned by each mission being 0.5- 1 kg, compared with many tens of kg of lunar samples returned by each of the six Apollo missions. Smaller samples require much more of the processing to be done under microscopic observation. In addition, the requirements for cleanliness and high-level containment would be difficult to satisfy while using traditional gloveboxes. JSC has constructed a laboratory to test concepts and technologies important to future sample curation. The Advanced Curation Laboratory includes a new-generation glovebox equipped with a robotic arm to evaluate the usability of robotic and teleoperated systems to perform curatorial tasks. The laboratory also contains equipment for precision cleaning and the measurement of trace organic contamination.

  8. Feasibility study of helical tomotherapy for total body or total marrow irradiation

    International Nuclear Information System (INIS)

    Hui, Susanta K.; Kapatoes, Jeff; Fowler, Jack; Henderson, Douglas; Olivera, Gustavo; Manon, Rafael R.; Gerbi, Bruce; Mackie, T. R.; Welsh, James S.

    2005-01-01

    Total body radiation (TBI) has been used for many years as a preconditioning agent before bone marrow transplantation. Many side effects still plague its use. We investigated the planning and delivery of total body irradiation (TBI) and selective total marrow irradiation (TMI) and a reduced radiation dose to sensitive structures using image-guided helical tomotherapy. To assess the feasibility of using helical tomotherapy (A) we studied variations in pitch, field width, and modulation factor on total body and total marrow helical tomotherapy treatments. We varied these parameters to provide a uniform dose along with a treatment times similar to conventional TBI (15-30 min). (B) We also investigated limited (head, chest, and pelvis) megavoltage CT (MVCT) scanning for the dimensional pretreatment setup verification rather than total body MVCT scanning to shorten the overall treatment time per treatment fraction. (C) We placed thermoluminescent detectors (TLDs) inside a Rando phantom to measure the dose at seven anatomical sites, including the lungs. A simulated TBI treatment showed homogeneous dose coverage (±10%) to the whole body. Doses to the sensitive organs were reduced by 35%-70% of the target dose. TLD measurements on Rando showed an accurate dose delivery (±7%) to the target and critical organs. In the TMI study, the dose was delivered conformally to the bone marrow only. The TBI and TMI treatment delivery time was reduced (by 50%) by increasing the field width from 2.5 to 5.0 cm in the inferior-superior direction. A limited MVCT reduced the target localization time 60% compared to whole body MVCT. MVCT image-guided helical tomotherapy offers a novel method to deliver a precise, homogeneous radiation dose to the whole body target while reducing the dose significantly to all critical organs. A judicious selection of pitch, modulation factor, and field size is required to produce a homogeneous dose distribution along with an acceptable treatment time. In

  9. Roadway sampling evaluation.

    Science.gov (United States)

    2014-09-01

    The Florida Department of Transportation (FDOT) has traditionally required that all sampling : and testing of asphalt mixtures be at the Contractors production facility. With recent staffing cuts, as : well as budget reductions, FDOT has been cons...

  10. Nevada National Security Site Integrated Groundwater Sampling Plan, Revision 0

    Energy Technology Data Exchange (ETDEWEB)

    Marutzky, Sam; Farnham, Irene

    2014-10-01

    The purpose of the Nevada National Security Site (NNSS) Integrated Sampling Plan (referred to herein as the Plan) is to provide a comprehensive, integrated approach for collecting and analyzing groundwater samples to meet the needs and objectives of the U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Field Office (NNSA/NFO) Underground Test Area (UGTA) Activity. Implementation of this Plan will provide high-quality data required by the UGTA Activity for ensuring public protection in an efficient and cost-effective manner. The Plan is designed to ensure compliance with the UGTA Quality Assurance Plan (QAP). The Plan’s scope comprises sample collection and analysis requirements relevant to assessing the extent of groundwater contamination from underground nuclear testing. This Plan identifies locations to be sampled by corrective action unit (CAU) and location type, sampling frequencies, sample collection methodologies, and the constituents to be analyzed. In addition, the Plan defines data collection criteria such as well-purging requirements, detection levels, and accuracy requirements; identifies reporting and data management requirements; and provides a process to ensure coordination between NNSS groundwater sampling programs for sampling of interest to UGTA. This Plan does not address compliance with requirements for wells that supply the NNSS public water system or wells involved in a permitted activity.

  11. Determination of colloidal and dissolved silver in water samples using colorimetric solid-phase extraction.

    Science.gov (United States)

    Hill, April A; Lipert, Robert J; Porter, Marc D

    2010-03-15

    The increase in bacterial resistance to antibiotics has led to resurgence in the use of silver as a biocidal agent in applications ranging from washing machine additives to the drinking water treatment system on the International Space Station (ISS). However, growing concerns about the possible toxicity of colloidal silver to bacteria, aquatic organisms and humans have led to recently issued regulations by the US EPA and FDA regarding the usage of silver. As part of an ongoing project, we have developed a rapid, simple method for determining total silver, both ionic (silver(I)) and colloidal, in 0.1-1mg/L aqueous samples, which spans the ISS potable water target of 0.3-0.5mg/L (total silver) and meets the US EPA limit of 0.1mg/L in drinking water. The method is based on colorimetric solid-phase extraction (C-SPE) and involves the extraction of silver(I) from water samples by passage through a solid-phase membrane impregnated with the colorimetric reagent DMABR (5-[4-(dimethylamino)benzylidene]rhodanine). Silver(I) exhaustively reacts with impregnated DMABR to form a colored compound, which is quantified using a handheld diffuse reflectance spectrophotometer. Total silver is determined by first passing the sample through a cartridge containing Oxone, which exhaustively oxidizes colloidal silver to dissolved silver(I). The method, which takes less than 2 min to complete and requires only approximately 1 mL of sample, has been validated through a series of tests, including a comparison with the ICP-MS analysis of a water sample from ISS that contained both silver(I) and colloidal silver. Potential earth-bound applications are also briefly discussed. Copyright (c) 2009 Elsevier B.V. All rights reserved.

  12. Supercritical Water Oxidation Total Organic Carbon (TOC) Analysis

    Science.gov (United States)

    The work presented here is the evaluation of the modified wet‐oxidation method described as Supercritical Water Oxidation (SCWO) for the analysis of total organic carbon (TOC) in very difficult oil/gas produced water sample matrices.

  13. Hydrogen production by the iodine-sulphur thermochemical cycle. Total and partial pressure measurements

    International Nuclear Information System (INIS)

    D Doizi; V Dauvois; J L Roujou; V Delanne; P Fauvet; B Larousse; O Hercher; P Carles; C Moulin

    2006-01-01

    The iodine sulphur thermochemical cycle appears to be one of the most promising candidate for the massive production of hydrogen using nuclear energy. The key step in this cycle is the HI distillation section which must be optimized to get a good efficiency of the overall cycle. The concept of reactive versus extractive distillation of HI has been proposed because of its potentiality. The design and the optimization of the reactive distillation column requires the knowledge of the liquid vapour equilibrium over the ternary HI-I 2 -H 2 O mixtures up to 300 C and 100 bars. A general methodology based on three experimental devices imposed by the very corrosive and concentrated media will be described: 1) I1 for the total pressure measurement versus different ternary compositions. 2) I2 for the partial and total pressure measurements around 130 C and 2 bars to validate the choice of the analytical optical 'online' techniques we have proposed. 3) I3 for the partial and total pressures measurements in the process domain. The results obtained on pure samples, binary mixtures HI-H 2 O and ternary mixtures using an experimental design analysis in the experimental device I2 will be discussed. (authors)

  14. A Portable Immunoassay Platform for Multiplexed Detection of Biotoxins in Clinical and Environmental Samples

    Energy Technology Data Exchange (ETDEWEB)

    Koh, Chung-Yan [Sandia National Lab. (SNL-CA), Livermore, CA (United States); Piccini, Matthew Ernest [Sandia National Lab. (SNL-CA), Livermore, CA (United States); Cepheid, Sunnyvale, CA (United States); Schaff, Ulrich Y. [Sandia National Lab. (SNL-CA), Livermore, CA (United States); Sandstone Diagnostics, Livermore, CA (United States); Stanker, Larry H. [US Dept. of Agriculture, Albany, CA (United States). Western Regional Research Center, Foodborne Contaminants Research Unit; Cheng, Luisa W. [US Dept. of Agriculture, Albany, CA (United States). Western Regional Research Center, Foodborne Contaminants Research Unit; Ravichandran, Easwaran [Univ. of Massachusetts, Dartmouth, MA (United States); Singh, Bal-Ram [Univ. of Massachusetts, Dartmouth, MA (United States); Sommer, Greg J. [Sandia National Lab. (SNL-CA), Livermore, CA (United States); Sandstone Diagnostics, Livermore, CA (United States); Singh, Anup K. [Sandia National Lab. (SNL-CA), Livermore, CA (United States)

    2015-01-01

    Multiple cases of attempted bioterrorism events using biotoxins have highlighted the urgent need for tools capable of rapid screening of suspect samples in the field (e.g., mailroom and public events). We present a portable microfluidic device capable of analyzing environmental (e.g., white powder), food (e.g., milk) and clinical (e.g., blood) samples for multiplexed detection of biotoxins. The device is rapid (<15-30 min sample-to-answer), sensitive (< 0.08 pg/mL detection limit for botulinum toxin), multiplexed (up to 64 parallel assays) and capable of analyzing small volume samples (< 20 μL total sample input). The immunoassay approach (SpinDx) is based on binding of toxins in a sample to antibody-laden capture particles followed by sedimentation of particles through a density-media in a microfluidic disk and quantification using a laser-induced fluorescence detector. A direct, blinded comparison with a gold standard ELISA revealed a 5-fold more sensitive detection limit for botulinum toxin while requiring 250-fold less sample volume and a 30 minute assay time with a near unity correlation. A key advantage of the technique is its compatibility with a variety of sample matrices with no additional sample preparation required. Ultrasensitive quantification has been demonstrated from direct analysis of multiple clinical, environmental and food samples, including white powder, whole blood, saliva, salad dressing, whole milk, peanut butter, half and half, honey, and canned meat. We believe that this device can met an urgent need in screening both potentially exposed people as well as suspicious samples in mail-rooms, airports, public sporting venues and emergency rooms. The general-purpose immunodiagnostics device can also find applications in screening of infectious and systemic diseases or serve as a lab device for conducting rapid immunoassays.

  15. Tank 241-AP-104 Grab Sampling and Analysis Plan

    International Nuclear Information System (INIS)

    TEMPLETON, A.M.

    2000-01-01

    This sampling and analysis plan (SAP) identifies characterization objectives pertaining to sample collection, laboratory analytical evaluation, and reporting requirements for samples obtained from tank 241-AP-104. The purpose of this sampling event is to obtain information about the characteristics of the contents of 241-AP-104 required to provide sample material to the Waste Treatment Contractor. Grab samples will be obtained from riser 001 to provide sufficient material for the chemical analyses and tests required to satisfy these data quality objectives and ICD-23. The 222-S Laboratory will receive samples; composite the samples; perform chemical analyses on composite samples; and provide samples to the Waste Treatment Contractor and the Process Chemistry Laboratory. The Process Chemistry Laboratory at the 222-S Laboratory Complex will perform process tests to evaluate the behavior of the 241-AP-104 waste undergoing the retrieval and treatment scenarios defined in the applicable DQOs. The Waste Treatment Contractor will perform process verification and waste form qualification tests. Requirements for analyses of samples originating in the L and H DQO process tests will be documented in the corresponding test plan (Person 2000) and are not within the scope of this SAP. This report provides the general methodology and procedures to be used in the preparation, retrieval, transport, analysis, and reporting of results from grab samples retrieved from tank 241-AP-104

  16. Preparation of in-house calibration source for the use in radioactivity analysis of the environmental samples. Consideration of homogeneity

    International Nuclear Information System (INIS)

    Aba, A.; Ismaeel, A.

    2013-01-01

    An in-house reference material has been prepared in Kuwait Institute for Scientific Research radioecology laboratory, for quality control purposes of gamma spectrometer systems. The material contains a known amount of uranium ore reference material (prepared by the International Atomic Energy Agency and coded as IAEA-RGU-1) which is mixed with marine sediment collected from Kuwait bay. The IAEA-RGU-1 has been certified that it is in equilibrium state with the decay daughters, and stable to be used for quality control purposes. Nevertheless, the homogeneous distribution of the doped material with the prepared source should be verified. This has been examined using gamma spectrometry measurements in conjunction with analysis of variance statistical tools, Dixon, box plots and Grubbs tests. The calculated total uncertainty has been utilized to establish the recommended specific activity ranges of 226 Ra, 224 Th, 214 Pb, 214 Bi and 210 Pb radioisotopes in the prepared source. The obtained results showed that the estimated uncertainty arising from the sample inhomogeneity has a significant contribution in the total uncertainty. The stability control charts of the ultra-low background gamma spectrometry system demonstrated the suitability of the prepared material for the purpose of quality control. However, the emitted gamma-rays from the prepared source covers the required energy range for determination of natural and artificial radionuclides in different species of environmental samples such as marine sediment, soil samples, and samples contaminated by naturally occurring radioactive material produced by oil industry. In addition, the material might be used for system calibration in case its traceability is proven. The experimental data revealed the significance of the homogeneity in preparing environmental samples for radioactivity measurements; in particular when small sample quantities of environmental samples are required to be analyzed. (author)

  17. Analysis of nutrition-relevant trace elements in human blood and serum by means of total reflection X-ray fluorescence (TXRF) spectroscopy

    International Nuclear Information System (INIS)

    Stosnach, Hagen; Mages, Margarete

    2009-01-01

    In clinical service laboratories, one of the most common analytical tasks with regard to inorganic traces is the determination of the nutrition-relevant elements Fe, Cu, Zn, and Se. Because of the high numbers of samples and the commercial character of these analyses, a time-consuming sample preparation must be avoided. In this presentation, the results of total reflection X-ray fluorescence measurements with a low-power system and different sample preparation procedures are compared with those derived from analysis with common methods like Atomic Absorption Spectroscopy (AAS) and Inductively Coupled Plasma Mass Spectroscopy (ICP-MS). The results of these investigations indicate that the optimal total reflection X-ray fluorescence analysis of the nutrition-relevant elements Fe, Cu, Zn, and Se can be performed by preparing whole blood and serum samples after dilution with ultrapure water and transferring 10 μl of internally standardized sample to an unsiliconized quartz glass sample carrier with subsequent drying in a laboratory oven. Suitable measurement time was found to be 600 s. The enhanced sample preparation by means of microwave or open digestion, in parts combined with cold plasma ashing, led to an improvement of detection limits by a factor of 2 for serum samples while for whole blood samples an improvement was only observed for samples prepared by means of microwave digestion. As the matrix elements P, S, Cl, and for whole blood Fe have a major influence on the detection limits, most probably a further enhancement of analytical quality requires the removal of the organic matrix. However, for the routine analysis of the nutrition-relevant elements, the dilution preparation was found to be sufficient.

  18. Data Validation Package September 2016 Groundwater and Surface Water Sampling at the Slick Rock, Colorado, Processing Sites January 2017

    Energy Technology Data Exchange (ETDEWEB)

    Traub, David [Navarro Research and Engineering, Inc., Oak Ridge, TN (United States); Nguyen, Jason [US Department of Energy, Washington, DC (United States)

    2017-01-04

    The Slick Rock, Colorado, Processing Sites are referred to as the Slick Rock West Processing Site (SRK05) and the Slick Rock East Processing Site (SRK06). This annual event involved sampling both sites for a total of 16 monitoring wells and 6 surface water locations as required by the 2006 Draft Final Ground Water Compliance Action Plan for the Slick Rock, Colorado, Processing Sites (GCAP). A domestic well was also sampled at a property adjacent to the Slick Rock East site at the request of the landowner.

  19. The influence of the self-absorption on the measure of the total alpha activity in water samples

    International Nuclear Information System (INIS)

    Acena, M.L.; Gonzalez, J.A.; De Pablo, A.

    1981-01-01

    The self-absorption is an important difficulty in measuring α-activities in river water samples. A semiempirical equation for calculating the self-absorption versus sample thickness has been obtained. This equation is valid for the regular saline residues in spanish rivers and for thicknesses lower than 2 mg x cm -2 . This figure sets a limit for the amount of water to be evaporated from the sample. (author)

  20. Validity of a portable glucose, total cholesterol, and triglycerides multi-analyzer in adults.

    Science.gov (United States)

    Coqueiro, Raildo da Silva; Santos, Mateus Carmo; Neto, João de Souza Leal; Queiroz, Bruno Morbeck de; Brügger, Nelson Augusto Jardim; Barbosa, Aline Rodrigues

    2014-07-01

    This study investigated the accuracy and precision of the Accutrend Plus system to determine blood glucose, total cholesterol, and plasma triglycerides in adults and evaluated its efficiency in measuring these blood variables. The sample consisted of 53 subjects (≥ 18 years). For blood variable laboratory determination, venous blood samples were collected and processed in a Labmax 240 analyzer. To measure blood variables with the Accutrend Plus system, samples of capillary blood were collected. In the analysis, the following tests were included: Wilcoxon and Student's t-tests for paired samples, Lin's concordance coefficient, Bland-Altman method, receiver operating characteristic curve, McNemar test, and k statistics. The results show that the Accutrend Plus system provided significantly higher values (p ≤ .05) of glucose and triglycerides but not of total cholesterol (p > .05) as compared to the values determined in the laboratory. However, the system showed good reproducibility (Lin's coefficient: glucose = .958, triglycerides = .992, total cholesterol = .940) and high concordance with the laboratory method (Lin's coefficient: glucose = .952, triglycerides = .990, total cholesterol = .944) and high sensitivity (glucose = 80.0%, triglycerides = 90.5%, total cholesterol = 84.4%) and specificity (glucose = 100.0%, triglycerides = 96.9%, total cholesterol = 95.2%) in the discrimination of high values of the three blood variables analyzed. It could be concluded that despite the tendency to overestimate glucose and triglyceride levels, a portable multi-analyzer is a valid alternative for the monitoring of metabolic disorders and cardiovascular risk factors. © The Author(s) 2013.