WorldWideScience

Sample records for total reflected light

  1. Timing the total reflection of light

    International Nuclear Information System (INIS)

    Chauvat, Dominique; Bonnet, Christophe; Dunseath, Kevin; Emile, Olivier; Le Floch, Albert

    2005-01-01

    We have identified for the first time the absolute delay at total reflection, envisioned by Newton. We show that there are in fact two divergent Wigner delays, depending on the polarisation of the incident light. These measurements give a new insight on the passage from total reflection to refraction

  2. Nonimaging light concentration using total internal reflection films.

    Science.gov (United States)

    Ouellette, G; Waltham, C E; Drees, R M; Poon, A; Schubank, R; Whitehead, L A

    1992-05-01

    We present a method of fabricating nonimaging light concentrators from total internal reflection film. A prototype has been made and tested and found to operate in agreement with predictions of ray-tracing codes. The performance of the prototype is comparable with that of concentrators made from specular reflecting materials.

  3. Exploiting total internal reflection geometry for efficient optical modulation of terahertz light

    Directory of Open Access Journals (Sweden)

    Xudong Liu

    2016-10-01

    Full Text Available Efficient methods to modulate terahertz (THz light are essential for realizing rapid THz imaging and communication applications. Here we report a novel THz modulator which utilizes the evanescent wave in a total internal reflection setup coupled with a conductive interface to enhance the attenuation efficiency of THz light. This approach makes it possible to achieve close to 100% modulation with a small interface conductivity of 12 mS. The frequency dependence of this technique is linked to the optical properties of the materials: a material with close to frequency independent conductivity that is also controllable will result in an achromatic modulation response, and the device performance can be optimized further by tuning the internal reflection angle. In this work, we focus on applying the technique in the terahertz frequency range. Using an LED array with a pump intensity of 475 mW/cm2 to produce carriers in a silicon wafer, we have achieved a modulation depth of up to 99.9% in a broad frequency range of 0.1 THz–0.8 THz. The required pumping power for the generation of the required free carriers is low because the sheet conductivity needed is far less than required for traditional transmission techniques. Consequently, the device can be modulated by an LED making it a very practical, low cost, and scalable solution for THz modulation.

  4. Frustrated total internal reflection in organic light-emitting diodes employing sphere cavity embedded in polystyrene

    International Nuclear Information System (INIS)

    Zhu, Peifen

    2016-01-01

    The light extraction efficiency of top-emitting organic light-emitting diodes (OLEDs) is numerically investigated employing the finite-difference time-domain method. The periodic nanostructures formed by embedding the sphere arrays in polystyrene (PS) are placed on top of OLED to frustrate the total internal reflection at the interface between OLED and free space. These nanostructures serve as an intermediate medium to extract the light out of OLED devices. Efficiently coupling both evanescent waves and propagation waves into spheres and subsequently extracting these light waves out of the sphere is key to achieving high extraction efficiency. By tuning the thickness of PS layer, both of the in-coupling efficiency and out-coupling efficiency are optimized for achieving high light extraction efficiency. Thicker PS layer results in higher in-coupling efficiency in sphere while the thinner PS layer leads to higher out-coupling efficiency. Thus the maximum light extraction is a trade-off between the in-coupling efficiency and out-coupling efficiency. The study shows that light extraction efficiency of 89% can be achieved by embedding 0.90 μm TiO 2 sphere in 0.30 μm PS layer with optimized in-coupling efficiency, out-coupling efficiency and cavity effect. (paper)

  5. Total internal reflection and dynamic light scattering microscopy of gels

    Science.gov (United States)

    Gregor, Brian F.

    Two different techniques which apply optical microscopy in novel ways to the study of biological systems and materials were built and applied to several samples. The first is a system for adapting the well-known technique of dynamic light scattering (DLS) to an optical microscope. This can detect and scatter light from very small volumes, as compared to standard DLS which studies light scattering from volumes 1000x larger. The small scattering volume also allows for the observation of nonergodic dynamics in appropriate samples. Porcine gastric mucin (PGM) forms a gel at low pH which lines the epithelial cell layer and acts as a protective barrier against the acidic stomach environment. The dynamics and microscopic viscosity of PGM at different pH levels is studied using polystyrene microspheres as tracer particles. The microscopic viscosity and microrheological properties of the commercial basement membrane Matrigel are also studied with this instrument. Matrigel is frequently used to culture cells and its properties remain poorly determined. Well-characterized and purely synthetic Matrigel substitutes will need to have the correct rheological and morphological characteristics. The second instrument designed and built is a microscope which uses an interferometry technique to achieve an improvement in resolution 2.5x better in one dimension than the Abbe diffraction limit. The technique is based upon the interference of the evanescent field generated on the surface of a prism by a laser in a total internal reflection geometry. The enhanced resolution is demonstrated with fluorescent samples. Additionally. Raman imaging microscopy is demonstrated using the evanescent field in resonant and non-resonant samples, although attempts at applying the enhanced resolution technique to the Raman images were ultimately unsuccessful. Applications of this instrument include high resolution imaging of cell membranes and macroscopic structures in gels and proteins. Finally, a third

  6. An Arduino-Based Experiment Designed to Clarify the Transition to Total Internal Reflection

    Science.gov (United States)

    Atkin, Keith

    2018-01-01

    The topic of refraction and reflection of light at the boundary of transparent media is a fundamentally important one. The special case of total internal reflection is however commonly misrepresented in elementary textbooks. This paper addresses the problem and describes an experimental procedure for measuring and displaying reflected and…

  7. Light reflection models for computer graphics.

    Science.gov (United States)

    Greenberg, D P

    1989-04-14

    During the past 20 years, computer graphic techniques for simulating the reflection of light have progressed so that today images of photorealistic quality can be produced. Early algorithms considered direct lighting only, but global illumination phenomena with indirect lighting, surface interreflections, and shadows can now be modeled with ray tracing, radiosity, and Monte Carlo simulations. This article describes the historical development of computer graphic algorithms for light reflection and pictorially illustrates what will be commonly available in the near future.

  8. Light Reflectance Spectroscopy to Detect Positive Surgical Margins on Prostate Cancer Specimens.

    Science.gov (United States)

    Morgan, Monica S C; Lay, Aaron H; Wang, Xinlong; Kapur, Payal; Ozayar, Asim; Sayah, Maryam; Zeng, Li; Liu, Hanli; Roehrborn, Claus G; Cadeddu, Jeffrey A

    2016-02-01

    Intraoperative frozen section analysis is not routinely performed to determine positive surgical margins at radical prostatectomy due to time requirements and unproven clinical usefulness. Light reflectance spectroscopy, which measures light intensity reflected or backscattered from tissues, can be applied to differentiate malignant from benign tissue. We used a novel light reflectance spectroscopy probe to evaluate positive surgical margins on ex vivo radical prostatectomy specimens and correlate its findings with pathological examination. Patients with intermediate to high risk disease undergoing radical prostatectomy were enrolled. Light reflectance spectroscopy was performed on suspected malignant and benign prostate capsule immediately following organ extraction. Each light reflectance spectroscopy at 530 to 830 nm was analyzed and correlated with pathological results. A regression model and forward sequential selection algorithm were developed for optimal feature selection. Eighty percent of light reflectance spectroscopy data were selected to train a logistic regression model, which was evaluated by the remaining 20% data. This was repeated 5 times to calculate averaged sensitivity, specificity and accuracy. Light reflectance spectroscopy analysis was performed on 17 ex vivo prostate specimens, on which a total of 11 histologically positive and 22 negative surgical margins were measured. Two select features from 700 to 830 nm were identified as unique to malignant tissue. Cross-validation when performing the predictive model showed that the optical probe predicted positive surgical margins with 85% sensitivity, 86% specificity, 86% accuracy and an AUC of 0.95. Light reflectance spectroscopy can identify positive surgical margins accurately in fresh ex vivo radical prostatectomy specimens. Further study is required to determine whether such analysis may be used in real time to improve surgical decision making and decrease positive surgical margin rates

  9. Total internal reflection effect on gyrotropic interface

    Science.gov (United States)

    Glushchenko, Alexander G.; Glushchenko, Eugene P.; Zhukov, Sergey V.

    2018-02-01

    This article considers the physical features of total internal reflection at gyrotropic and isotropic interfaces for two cases: electrical gyrotropy (plasma) and magnetic gyrotropy (ferrite). It is shown that the plasma magnetization may lead to the formation of the total internal reflection effect, which does not occur in isotropic plasma. The threshold values of the magnetic field, which are necessary for the total internal reflection effect, are determined. The total internal reflection effect on a ferrite-dielectric interface for waves emanating from different angles is observed in various frequency ranges and magnetization fields. The study points out the possibility of changing the total internal reflection angle value in large limits due to a change in the external magnetic field magnitude. The calculation results of the total internal reflection angle dependence on the external magnetic field magnitude are presented. The formulas are elaborated for calculating the total internal reflection angles of different interfaces for gyrotropic and isotropic media. The generalized formulas are defined for calculating the Doppler effect in the gyrotropic media. The study demonstrates how the velocity of the media interface affects the limiting angle of total internal refection.

  10. Effect of surface plasmon polaritons on the sensitivity of refractive index measurement using total internal reflection method

    International Nuclear Information System (INIS)

    Roshan Entezar, S.

    2015-01-01

    The phase difference between two p-polarized and s-polarized plane waves which are reflected under total internal reflection from the base of a prism with a thin metal coating is studied. Typically such a quantity can be used to measure the refractive index of a test material using the total internal reflection method. It is shown that due to the excitation of surface plasmon polaritons at the interface between the tested dielectric material and the thin metal layer, the p-polarized light experiences a large phase shift which enlarges the phase difference between the p-polarized and the s-polarized waves. As a result, the sensitivity of refractive index measurement increases and the error in determining the refractive index decreases. - Highlights: • Phase difference of totally internally reflected p and s polarized beams is studied. • Excitation of the surface wave increases the phase shift of the p-polarized light. • The sensitivity of refractive index measurement increases by using a coated prism. • The error in determining the refractive index decreases using the coated prism

  11. Studies of the Reflection, Refraction and Internal Reflection of Light

    Science.gov (United States)

    Lanchester, P. C.

    2014-01-01

    An inexpensive apparatus and associated experiments are described for studying the basic laws of reflection and refraction of light at an air-glass interface, and multiple internal reflections within a glass block. In order to motivate students and encourage their active participation, a novel technique is described for determining the refractive…

  12. Total and available metal contents in sediments by synchrotron radiation total reflection X-ray fluorescence

    International Nuclear Information System (INIS)

    Moreira, Silvana; Sobrinho, Gilmar A.; Jesus, Edgar F.O. de; Lopes, Ricardo T.

    2002-01-01

    In this work the total and available contents of Al, Si, Cl, K, Mn, Fe, Co, Ni, Cu, Zn, Sr, Zr, Ba, Ce and Pb in sediments from river Atibaia were determined by Synchrotron Radiation Total Reflection X-Ray Fluorescence technique. The detection limits for K series varies from 200 ng.mL -1 for Al to 2 ng.mL -1 for Zn while for L series the value varies from 20 ng.mL -1 for Ba to 10 ng.mL -1 for Pb. The samples were submitted to two different processes, in order to obtain the total and biological available metal contents. The information about metal content is a important parameter for a correct evaluation about the hydrologic cycle in Piracicaba basin. All the measure were carried out at the National Synchrotron Light Laboratory, Campinas, SP, Brazil, using a white beam for excitation. (author)

  13. Excitations of surface plasmon polaritons by attenuated total reflection, revisited

    International Nuclear Information System (INIS)

    Barchesi, D.; Otto, A.

    2013-01-01

    Many textbooks and review papers are devoted to plasmonics based on a selection of the numerous bibliography. But none describes the details of the first culmination of plasmonics in 1968, when surface plasmons become a field of optics. The coupling of light with the surface plasmon leads to the surface plasmon polariton (SPP). Therefore, the authors chose to associate historical insight (not avoiding a personal touch), a modern mathematical formulation of the excitation of the SPP by attenuated total reflection (ATR), considered as well understood since decades, and experimental applications since 1969, including recent developments.

  14. Measuring Light Reflectance of BGO Crystal Surfaces

    Science.gov (United States)

    Janecek, Martin; Moses, William W.

    2008-10-01

    A scintillating crystal's surface reflectance has to be well understood in order to accurately predict and optimize the crystal's light collection through Monte Carlo simulations. In this paper, we measure the inner surface reflectance properties for BGO. The measurements include BGO crystals with a mechanically polished surface, rough-cut surface, and chemically etched surface, and with various reflectors attached, both air-coupled and with coupling compound. The measurements are performed with a laser aimed at the center of a hemispherical shaped BGO crystal. The hemispherical shape eliminates any non-perpendicular angles for light entering and exiting the crystal. The reflected light is collected with an array of photodiodes. The laser can be set at an arbitrary angle, and the photodiode array is rotated to fully cover 2pi of solid angle. The current produced in the photodiodes is readout with a digital multimeter connected through a multiplexer. The two rows of photodiodes achieve 5-degree by 4-degree resolution, and the current measurement has a dynamic range of 105:1. The acquired data was not described by the commonly assumed linear combination of specular and diffuse (Lambertian) distributions, except for a very few surfaces. Surface roughness proved to be the most important parameter when choosing crystal setup. The reflector choice was of less importance and of almost no consequence for rough-cut surfaces. Pure specular reflection distribution for all incidence angles was measured for polished surfaces with VM2000 film, while the most Lambertian distribution for any surface finish was measured for titanium dioxide paint. The distributions acquired in this paper will be used to create more accurate Monte Carlo models for light reflection distribution within BGO crystals.

  15. Effects of snow-reflected light levels on human visual comfort.

    Science.gov (United States)

    Yilmaz, Hasan; Demircioglu Yildiz, Nalan; Yilmaz, Sevgi

    2008-09-01

    The intensity of the sunlight reflected by the snow-covered surfaces is so high that it may disturb humans many times. This study aims to determine the reflected sunlight intensities from snow covered areas at points near (at a distance of 2 m) and under an individual tree and among trees (in the forest area) by accepting the open area as control; the reducing effects of the plant materials on reflected sunlight in percentage by comparing with the values of the open (control) area; and critical reflected sunlight threshold values for human visual comfort. The study was carried out over 22 clear and calm, i.e. sky was cloudless and wind was calm, days between the 1st and 31st days of January 2004, at 8:30 in the morning, at 12:30 at noon and at 14:30 in the afternoon in Erzurum. In order to determine the discomforting light intensity levels, 25 females and 26 male (totally 51) student subjects whose mean age was 20 and who had no visual disorders were selected. Considering the open area as control, mean reflected sunlight reducing effects were found to be 19.0, 66.0 and 82.7% for the 2 m near a tree, under a tree, and forest area, respectively. According to the responses of 51 subjects in the study, visually "very comfortable" range is between 5,000 and 8,000 lx; "comfortable" range is between 11,000 and 75,000 lx (mostly at 12,000 lx); "uncomfortable" condition is above the light intensity value of 43,000 lx and "very uncomfortable" condition is above the intensity of 80,000 lx. Great majority of the subjects (91%) found the value of 103,000 lx to be "very uncomfortable." As it is not an applicable way to use the great and dense tree masses in the cities, at least individual trees should be used along the main pedestrian axels in the cities having the same features with Erzurum to prevent the natural light pollution and discomforting effects of the snow-reflected sunlight.

  16. Total reflection X-ray fluorescence analysis

    International Nuclear Information System (INIS)

    Michaelis, W.; Prange, A.

    1987-01-01

    In the past few years, total reflection X-ray flourescence analysis (TXRF) has found an increasing number of assignments and applications. Experience of trace element analysis using TXRF and examples of applications are already widespread. Therefore, users of TXRF had the opportunity of an intensive exchange of their experience at the 1st workshop on total reflection X-ray fluorescence analysis which took place on May 27th and 28th 1986 at the GKSS Research Centre at Geesthacht. In a series of lectures and discussions dealing with the analytical principle itself, sample preparation techniques and applications as well as comuter programs for spectrum evaluation, the present state of development and the range of applications were outlined. 3 studies out of a total of 14 were included separately in the INIS and ENERGY databases. With 61 figs., 12 tabs [de

  17. Bidirectional reflectance distribution function of Spectralon white reflectance standard illuminated by incoherent unpolarized and plane-polarized light.

    Science.gov (United States)

    Bhandari, Anak; Hamre, Børge; Frette, Øvynd; Zhao, Lu; Stamnes, Jakob J; Kildemo, Morten

    2011-06-01

    A Lambert surface would appear equally bright from all observation directions regardless of the illumination direction. However, the reflection from a randomly scattering object generally has directional variation, which can be described in terms of the bidirectional reflectance distribution function (BRDF). We measured the BRDF of a Spectralon white reflectance standard for incoherent illumination at 405 and 680 nm with unpolarized and plane-polarized light from different directions of incidence. Our measurements show deviations of the BRDF for the Spectralon white reflectance standard from that of a Lambertian reflector that depend both on the angle of incidence and the polarization states of the incident light and detected light. The non-Lambertian reflection characteristics were found to increase more toward the direction of specular reflection as the angle of incidence gets larger.

  18. Photometric measurements of red blood cell aggregation: light transmission versus light reflectance

    NARCIS (Netherlands)

    Baskurt, O.K.; Uyuklu, M.; Hardeman, M.R.; Meiselman, H.J.

    2009-01-01

    Red blood cell (RBC) aggregation is the reversible and regular clumping in the presence of certain macromolecules. This is a clinically important phenomenon, being significantly enhanced in the presence of acute phase reactants (e. g., fibrinogen). Both light reflection (LR) and light transmission

  19. Photometric measurements of red blood cell aggregation: light transmission versus light reflectance

    NARCIS (Netherlands)

    Baskurt, Oguz K.; Uyuklu, Mehmet; Hardeman, Max R.; Meiselman, Herbert J.

    2009-01-01

    Red blood cell (RBC) aggregation is the reversible and regular clumping in the presence of certain macromolecules. This is a clinically important phenomenon, being significantly enhanced in the presence of acute phase reactants (e.g., fibrinogen). Both light reflection (LR) and light transmission

  20. Reflected Light Curves of Extrasolar Planets

    Science.gov (United States)

    Green, D.; Matthews, J.; Kuschnig, R.; Seager, S.

    The planned launches of ultra-precise photometric satellites such as MOST, COROT and MONS should provide the first opportunity to study the reflected light curves from extrasolar planets. To predict the capabilities of these missions, we have constructed a series of models of such light curves, improving upon the Monte Carlo simulations by Seager et al. (2000). These models include more realistic features such limb darkening of the star and broad band photometry. For specific models, the resulting planet light curves exhibit unique behavior with the variation of radius, inclination and presence or absence of clouds.

  1. Beam line optics technologies series (7). Orthopedic treatment of sharp of light (reflecting mirror)

    International Nuclear Information System (INIS)

    Uruga, Tomoya; Nomura, Masaharu

    2006-01-01

    A reflecting mirror (mirror) is the most popular light device for orthopedic treatment of the shape of light. The paper explains the kinds of mirror for hard X-ray field and its applications in order to think the objects of mirror and how to adjust it when user experiment on the beam-line. The basic knowledge of reflection of X-ray, a use of mirror, the kinds of condenser mirror, the influence factors on the condenser size, arrangement of mirror in the hard X-ray beam-line, what kinds of mirror are necessary, evaluation of performance of mirror and adjustment, and troubles and measures are described. Layout in optics hutch at BL01B1 at SPring-8, refraction and total reflection of X-rays at surface, reflectivity of Rh and Pt with ideal surface as a function of photon energy, effects of surface roughness on reflectivity of Rh, calculated beam sizes for typical SPring-8 mirror as a function of magnification, schematic drawing of mirror, standard mirror system for vertical deflection in bending magnet beam-line, and observed and calculated reflectivity of Rh double mirror at BL01B1 at SPring-8 are illustrated. (S.Y)

  2. Frustrated Total Internal Reflection: A Simple Application and Demonstration.

    Science.gov (United States)

    Zanella, F. P.; Magalhaes, D. V.; Oliveira, M. M.; Bianchi, R. F.; Misoguti, L.; Mendonca, C. R.

    2003-01-01

    Describes the total internal reflection process that occurs when the internal angle of incidence is equal to or greater than the critical angle. Presents a demonstration of the effect of frustrated total internal reflection (FTIR). (YDS)

  3. Detection limit calculations for different total reflection techniques

    International Nuclear Information System (INIS)

    Sanchez, H.J.

    2000-01-01

    In this work, theoretical calculations of detection limits for different total-reflection techniques are presented.. Calculations include grazing incidence (TXRF) and gracing exit (GEXRF) conditions. These calculations are compared with detection limits obtained for conventional x-ray fluorescence (XRF). In order to compute detection limits the Shiraiwa and Fujino's model to calculate x-ray fluorescence intensities was used. This model made certain assumptions and approximations to achieve the calculations, specially in the case of the geometrical conditions of the sample, and the incident and takeoff beams. Nevertheless the calculated data of detection limits for conventional XRF and total-reflection XRF show a good agreement with previous results. The model proposed here allows to analyze the different sources of background and the influence of the excitation geometry, which contribute to the understanding of the physical processes involved in the XRF analysis by total reflection. Finally, a comparison between detection limits in total-reflection analysis at grazing incidence and at grazing exit is carried out. Here a good agreement with the theoretical predictions of the reversibility principle is found, showing that detection limits are similar for both techniques. (author)

  4. Total reflection X-ray photoelectron spectroscopy: A review

    International Nuclear Information System (INIS)

    Kawai, Jun

    2010-01-01

    Total reflection X-ray photoelectron spectroscopy (TRXPS) is reviewed and all the published papers on TRXPS until the end of 2009 are included. Special emphasis is on the historical development. Applications are also described for each report. The background reduction is the most important effect of total reflection, but interference effect, relation to inelastic mean free path, change of probing depth are also discussed.

  5. Total-reflection X-ray fluorescence analysis of Austrian wine

    International Nuclear Information System (INIS)

    Gruber, X.; Kregsamer, P.; Wobrauschek, P.; Streli, C.

    2006-01-01

    The concentration of major, minor and trace elements in Austrian wine was determined by total-reflection X-ray fluorescence using gallium as internal standard. A multi-elemental analysis was possible by pipetting 6 μl of wine directly on the reflector and drying. Total-reflection X-ray fluorescence analysis was performed with Atomika EXTRA II A (Cameca) X-rays from a Mo tube with a high-energy cut-off at 20 keV in total-reflection geometry. The results showed that it was possible to identify only by the elemental analysis as fingerprint the vineyards and year of vintage among 11 different wines

  6. Total-reflection X-ray fluorescence analysis of Austrian wine

    Energy Technology Data Exchange (ETDEWEB)

    Gruber, X. [Atominstitut der Osterreichischen Universitaeten, 1020 Vienna (Austria); Kregsamer, P. [Atominstitut der Osterreichischen Universitaeten, 1020 Vienna (Austria); Wobrauschek, P. [Atominstitut der Osterreichischen Universitaeten, 1020 Vienna (Austria); Streli, C. [Atominstitut der Osterreichischen Universitaeten, 1020 Vienna (Austria)]. E-mail: streli@ati.ac.at

    2006-11-15

    The concentration of major, minor and trace elements in Austrian wine was determined by total-reflection X-ray fluorescence using gallium as internal standard. A multi-elemental analysis was possible by pipetting 6 {mu}l of wine directly on the reflector and drying. Total-reflection X-ray fluorescence analysis was performed with Atomika EXTRA II A (Cameca) X-rays from a Mo tube with a high-energy cut-off at 20 keV in total-reflection geometry. The results showed that it was possible to identify only by the elemental analysis as fingerprint the vineyards and year of vintage among 11 different wines.

  7. Reflection of a polarized light cone

    Science.gov (United States)

    Brody, Jed; Weiss, Daniel; Berland, Keith

    2013-01-01

    We introduce a visually appealing experimental demonstration of Fresnel reflection. In this simple optical experiment, a polarized light beam travels through a high numerical-aperture microscope objective, reflects off a glass slide, and travels back through the same objective lens. The return beam is sampled with a polarizing beam splitter and produces a surprising geometric pattern on an observation screen. Understanding the origin of this pattern requires careful attention to geometry and an understanding of the Fresnel coefficients for S and P polarized light. We demonstrate that in addition to a relatively simple experimental implementation, the shape of the observed pattern can be computed both analytically and by using optical modeling software. The experience of working through complex mathematical computations and demonstrating their agreement with a surprising experimental observation makes this a highly educational experiment for undergraduate optics or advanced-lab courses. It also provides a straightforward yet non-trivial system for teaching students how to use optical modeling software.

  8. Development of an ultra-compact mid-infrared attenuated total reflectance spectrophotometer

    Science.gov (United States)

    Kim, Dong Soo; Lee, Tae-Ro; Yoon, Gilwon

    2014-07-01

    Mid-infrared spectroscopy has been an important tool widely used for qualitative analysis in various fields. However, portable or personal use is size and cost prohibitive for either Fourier transform infrared or attenuated total reflectance (ATR) spectrophotometers. In this study, we developed an ultra-compact ATR spectrophotometer whose frequency band was 5.5-11.0 μm. We used miniature components, such as a light source fabricated by semiconductor technology, a linear variable filter, and a pyro-electric array detector. There were no moving parts. Optimal design based on two light sources, a zippered configuration of the array detector and ATR optics could produce absorption spectra that might be used for qualitative analysis. A microprocessor synchronized the pulsed light sources and detector, and all the signals were processed digitally. The size was 13.5×8.5×3.5 cm3 and the weight was 300 grams. Due to its low cost, our spectrophotometer can replace many online monitoring devices. Another application could be for a u-healthcare system installed in the bathroom or attached to a smartphone for monitoring substances in body fluids.

  9. Analysis of thin-film polymers using attenuated total internal reflection-Raman microspectroscopy.

    Science.gov (United States)

    Tran, Willie; Tisinger, Louis G; Lavalle, Luis E; Sommer, André J

    2015-01-01

    Two methods commonly employed for molecular surface analysis and thin-film analysis of microscopic areas are attenuated total reflection infrared (ATR-IR) microspectroscopy and confocal Raman microspectroscopy. In the former method, the depth of the evanescent probe beam can be controlled by the wavelength of light, the angle of incidence, or the refractive index of the internal reflection element. Because the penetration depth is proportional to the wavelength of light, one could interrogate a smaller film thickness by moving from the mid-infrared region to the visible region employing Raman spectroscopy. The investigation of ATR Raman microspectroscopy, a largely unexplored technique available to Raman microspectroscopy, was carried out. A Renishaw inVia Raman microscope was externally modified and used in conjunction with a solid immersion lens (SIL) to perform ATR Raman experiments. Thin-film polymer samples were analyzed to explore the theoretical sampling depth for experiments conducted without the SIL, with the SIL, and with the SIL using evanescent excitation. The feasibility of micro-ATR Raman was examined by collecting ATR spectra from films whose thickness measured from 200 to 60 nm. Films of these thicknesses were present on a much thicker substrate, and features from the underlying substrate did not become visible until the thin film reached a thickness of 68 nm.

  10. Bistable enhanced total reflection in Kretschmann configuration containing a saturable gain medium.

    Science.gov (United States)

    Zhou, Haichun; Guo, Jie; Xu, Kun; Li, Zhe; Tang, Junqi; Man, Shiqing

    2018-03-05

    The reflection of a TM-polarized light beam from a Kretschmann configuration with a saturable gain medium is investigated theoretically. Here, the dielectric constant of the gain medium is described by a classical Lorentzian oscillator model. When surface plasmon polaritons are effectively excited in this structure, it is demonstrated that the curves of enhanced total reflection (ETR) show different shaped hysteresis loops associated with optical bistability owing to gain saturation effect. The effects of the angle of incidence, the thickness of metal film, and the value of small-signal gain on bistable ETR are discussed in detail in a homogeneously broadened (HB) gain medium at line center. Analogous results can also be obtained in an inhomogeneously broadened (inHB) gain medium, while the two switch thresholds and the width of optical bistability hysteresis in an inHB gain medium are significantly different from those in a HB gain medium.

  11. REFLECTED LIGHT CURVES, SPHERICAL AND BOND ALBEDOS OF JUPITER- AND SATURN-LIKE EXOPLANETS

    Energy Technology Data Exchange (ETDEWEB)

    Dyudina, Ulyana; Kopparla, Pushkar; Ingersoll, Andrew P.; Yung, Yuk L. [Division of Geological and Planetary Sciences, 150-21 California Institute of Technology, Pasadena, CA 91125 (United States); Zhang, Xi [University of California Santa Cruz 1156 High Street, Santa Cruz, CA 95064 (United States); Li, Liming [Department of Physics, University of Houston, Houston, TX 77204 (United States); Dones, Luke [Southwest Research Institute, 1050 Walnut Street, Suite 300, Boulder CO 80302 (United States); Verbiscer, Anne, E-mail: ulyana@gps.caltech.edu [Department of Astronomy, University of Virginia, Charlottesville, VA 22904-4325 (United States)

    2016-05-10

    Reflected light curves observed for exoplanets indicate that a few of them host bright clouds. We estimate how the light curve and total stellar heating of a planet depends on forward and backward scattering in the clouds based on Pioneer and Cassini spacecraft images of Jupiter and Saturn. We fit analytical functions to the local reflected brightnesses of Jupiter and Saturn depending on the planet’s phase. These observations cover broadbands at 0.59–0.72 and 0.39–0.5 μ m, and narrowbands at 0.938 (atmospheric window), 0.889 (CH4 absorption band), and 0.24–0.28 μ m. We simulate the images of the planets with a ray-tracing model, and disk-integrate them to produce the full-orbit light curves. For Jupiter, we also fit the modeled light curves to the observed full-disk brightness. We derive spherical albedos for Jupiter and Saturn, and for planets with Lambertian and Rayleigh-scattering atmospheres. Jupiter-like atmospheres can produce light curves that are a factor of two fainter at half-phase than the Lambertian planet, given the same geometric albedo at transit. The spherical albedo is typically lower than for a Lambertian planet by up to a factor of ∼1.5. The Lambertian assumption will underestimate the absorption of the stellar light and the equilibrium temperature of the planetary atmosphere. We also compare our light curves with the light curves of solid bodies: the moons Enceladus and Callisto. Their strong backscattering peak within a few degrees of opposition (secondary eclipse) can lead to an even stronger underestimate of the stellar heating.

  12. Spectrum of reflected light by self-focusing of light in a laser plasma

    International Nuclear Information System (INIS)

    Gorbunov, L.M.

    1983-01-01

    The spectrum of the radiation reflected by a laser-produced plasma is considered. In this situation, self-focusing occurs and a region of low density (caviton) is formed. It is shown that the process leads to a considerable broadening of the spectrum on the ''red'' side, and to the appearance of a line structure in the spectrum. The results can explain data for the reflected light spectrum [L. M. Gorbunov et al., FIAN Preprint No. 126 (1979)] as being due to the nonstationary self-focusing of light in a laser-produced plasma that has recently been observed [V. L. Artsimovich et al., FIAN Preprint No. 252 (1981); Sov. Phys. Doklady 27, 618 (1982)

  13. The conditions for total reflection of low-energy atoms from crystal surfaces

    International Nuclear Information System (INIS)

    Hou, M.; Robinson, M.T.

    1978-01-01

    The critical angles for the total reflection of low-energy particles from Cu rows and (001) planes have been investigated, using the binary collision approximation computer simulation code MARLOWE Breakthrough angles were evaluated for H, N, Ne, Ar, Cu, Xe, and Au in the energy range from 0.1 to 7.5 keV. In both the axial and the planar cases, recoiling of the target atoms lowers the energy barrier which the target surface presents to the heavy projectiles. Consequently, the breakthrough angles are reduced for heavy projectiles below the values expected either from observations on light projectiles or from analytical channeling theory. (orig.) [de

  14. Do cephalopods communicate using polarized light reflections from their skin?

    Science.gov (United States)

    Mäthger, Lydia M; Shashar, Nadav; Hanlon, Roger T

    2009-07-01

    Cephalopods (squid, cuttlefish and octopus) are probably best known for their ability to change color and pattern for camouflage and communication. This is made possible by their complex skin, which contains pigmented chromatophore organs and structural light reflectors (iridophores and leucophores). Iridophores create colorful and linearly polarized reflective patterns. Equally interesting, the photoreceptors of cephalopod eyes are arranged in a way to give these animals the ability to detect the linear polarization of incoming light. The capacity to detect polarized light may have a variety of functions, such as prey detection, navigation, orientation and contrast enhancement. Because the skin of cephalopods can produce polarized reflective patterns, it has been postulated that cephalopods could communicate intraspecifically through this visual system. The term 'hidden' or 'private' communication channel has been given to this concept because many cephalopod predators may not be able to see their polarized reflective patterns. We review the evidence for polarization vision as well as polarization signaling in some cephalopod species and provide examples that tend to support the notion--currently unproven--that some cephalopods communicate using polarized light signals.

  15. All-optical microscope autofocus based on an electrically tunable lens and a totally internally reflected IR laser.

    Science.gov (United States)

    Bathe-Peters, M; Annibale, P; Lohse, M J

    2018-02-05

    Microscopic imaging at high spatial-temporal resolution over long time scales (minutes to hours) requires rapid and precise stabilization of the microscope focus. Conventional and commercial autofocus systems are largely based on piezoelectric stages or mechanical objective actuators. Objective to sample distance is either measured by image analysis approaches or by hardware modules measuring the intensity of reflected infrared light. We propose here a truly all-optical microscope autofocus taking advantage of an electrically tunable lens and a totally internally reflected infrared probe beam. We implement a feedback-loop based on the lateral position of a totally internally reflected infrared laser on a quadrant photodetector, as an indicator of the relative defocus. We show here how to treat the combined contributions due to mechanical defocus and deformation of the tunable lens. As a result, the sample can be kept in focus without any mechanical movement, at rates up to hundreds of Hertz. The device requires only reflective optics and can be implemented at a fraction of the cost required for a comparable piezo-based actuator.

  16. Reflection and refraction of light from a moving block of glass

    International Nuclear Information System (INIS)

    Lerche, I.

    1975-01-01

    For a block of glass moving with speed βc we present calculations which give the changes in the laws of reflection and refraction of light from the laws which hold when β = 0. In particular we show (i) that changes in the critical internal reflection condition, although formally of order β 2 , are obtainable by measuring the refraction angle to O(β); (ii) the reflection coefficient depends not only on the polarization plane of the incident light but also on whether the plane of incidence does, or does not, include the direction of motion of the glass block. For instance, for light incident in a plane perpendicular to the direction of motion there is no Brewster angle for either plane of polarization, while for light incident in a plane containing the direction of motion at least one (and sometimes both) plane of polarization possess a Brewster angle. We have done these calculations in order to demonstrate that the shearing of one medium relative to another can have profound effects on the reflection and refraction of light. A major point here is that even when it might appear a priori that O(β 2 ) phenomena are unobservable in the laboratory, the present calculations show that this is not always so

  17. Developement of a Light Attenuator Based on Glassy Reflections ...

    African Journals Online (AJOL)

    The light intensity control of a luminous source is a very important operation in many optical applications. Several types of light attenuator exploiting different optical phenomena like diffraction, absorption, and reflection exist and they differ principally in the maximum attenuation rate, the control range, the sensitivity and the ...

  18. Method of Detecting Coliform Bacteria from Reflected Light

    Science.gov (United States)

    Vincent, Robert K. (Inventor)

    2014-01-01

    The present invention relates to a method of detecting coliform bacteria in water from reflected light, and also includes devices for the measurement, calculation and transmission of data relating to that method.

  19. Method of Detecting Coliform Bacteria and Escherichia Coli Bacteria from Reflected Light

    Science.gov (United States)

    Vincent, Robert (Inventor)

    2013-01-01

    The present invention relates to a method of detecting coliform bacteria in water from reflected light and a method of detecting Eschericha Coli bacteria in water from reflected light, and also includes devices for the measurement, calculation and transmission of data relating to that method.

  20. Variable-angle total internal reflection fluorescence microscopy of intact cells of Arabidopsis thaliana

    Directory of Open Access Journals (Sweden)

    Kim Myung K

    2011-09-01

    Full Text Available Abstract Background Total internal reflection fluorescence microscopy (TIRFM is a powerful tool for observing fluorescently labeled molecules on the plasma membrane surface of animal cells. However, the utility of TIRFM in plant cell studies has been limited by the fact that plants have cell walls, thick peripheral layers surrounding the plasma membrane. Recently, a new technique known as variable-angle epifluorescence microscopy (VAEM was developed to circumvent this problem. However, the lack of a detailed analysis of the optical principles underlying VAEM has limited its applications in plant-cell biology. Results Here, we present theoretical and experimental evidence supporting the use of variable-angle TIRFM in observations of intact plant cells. We show that when total internal reflection occurs at the cell wall/cytosol interface with an appropriate angle of incidence, an evanescent wave field of constant depth is produced inside the cytosol. Results of experimental TIRFM observations of the dynamic behaviors of phototropin 1 (a membrane receptor protein and clathrin light chain (a vesicle coat protein support our theoretical analysis. Conclusions These findings demonstrate that variable-angle TIRFM is appropriate for quantitative live imaging of cells in intact tissues of Arabidopsis thaliana.

  1. Monte Carlo simulation of light reflection from cosmetic powders on the skin

    Science.gov (United States)

    Okamoto, Takashi; Motoda, Masafumi; Igarashi, Takanori; Nakao, Keisuke

    2011-07-01

    The reflection and scattering properties of light incident on skin covered with powder particles have been investigated. A three-layer skin structure with a spot is modeled, and the propagation of light in the skin and the scattering of light by particles on the skin surface are simulated by means of a Monte Carlo method. Under the condition in which only single scattering of light occurs in the powder layer, the reflection spectra of light from the skin change dramatically with the size of powder particles. The color difference between normal skin and spots is found to diminish more when powder particles smaller than the wavelength of light are used. It is shown that particle polydispersity suppresses substantially the extreme spectral change caused by monodisperse particles with a size comparable to the light wavelength.

  2. Multielemental analysis in Brazilian cigarettes using total reflection X-ray fluorescence with synchrotron radiation

    International Nuclear Information System (INIS)

    Serpa, Renata F.B.; Jesus, Edgar F.O. de; Lopes, Ricardo T.; Moreira, Silvana

    2005-01-01

    In order to identify major and trace elements in conventional and light Brazilian cigarettes, Total Reflection X-Ray Fluorescence with Synchrotron Radiation (SR-TXRF) was used. The fluorescence measurements were carried out at Brazilian Synchrotron Light Laboratory, Campinas - Sao Paulo. This technique enables detection limit is in the ngg -1 range, which is very useful in elemental tobacco smoke analysis, since it presents most of its elements at a trace level. The major elements identified in tobacco samples were: S, Cl, K, Ca, Mn, Fe and Cd, and the trace elements were: Ti, Cr, Ni, Cu, Zn, Br, Rb, Sr and Ba. However in tobacco smoke samples, there were only two major elements: K and Ca, the others were present a trace level. The rate transfer of tobacco to tobacco smoke was about 2.5 % for all elements studied. (author)

  3. Further improvement in the light output power of InGaN-based light emitting diodes by reflective current blocking design

    International Nuclear Information System (INIS)

    Tsai, Chun-Fu; Su, Yan-Kuin; Lin, Chun-Liang

    2011-01-01

    In this study, the fabrication and characterization of InGaN/GaN multiple-quantum-well light-emitting diodes (LEDs) with further improvement by the design of a reflective current blocking layer (CBL) were described, and these are demonstrated to be an inexpensive and feasible way for improving the performance of LEDs. With the reflective CBL, not only was the injected current forced to spread outside instead of flowing directly downward under a p-pad, but the light generated from the active region could also be extracted outside of the LED by reflection under the p-pad. At 20 mA, as compared to the conventional LED, the light output power of the LEDs with the normal and reflective CBL can be increased by 15.7% and 25.8%, respectively. We found that the forward voltages of the LEDs with CBL structure were both about 3.7 V at 20 mA, which was slightly higher than that of the conventional LED (3.6 V). In our experiment, the further increase in the light output power of the reflective CBL LED could be attributed to more current injection into the light-emitting active region outside of the p-pad by the CBL and a reduction in optical absorption at the p-pad with more extraction by the reflective design

  4. On the reflection point where light reflects to a known destination on quadratic surfaces.

    Science.gov (United States)

    Gonçalves, Nuno

    2010-01-15

    We address the problem of determining the reflection point on a specular surface where a light ray that travels from a source to a target is reflected. The specular surfaces considered are those expressed by a quadratic equation. So far, there is no closed form explicit equation for the general solution of this determination of the reflection point, and the usual approach is to use the Snell law or the Fermat principle whose equations are derived in multidimensional nonlinear minimizations. We prove in this Letter that one can impose a set of three restrictions to the reflection point that can impose a set of three restrictions that culminates in a very elegant formalism of searching the reflection point in a unidimensional curve in space. This curve is the intersection of two quadratic equations. Some applications of this framework are also discussed.

  5. Electro-optic study of PZT ferroelectric ceramics using modulation of reflected light

    Science.gov (United States)

    Kniazkov, A. V.

    2016-04-01

    Electro-optic coefficients of variations in the refractive index of PZT and PLZT ceramic materials induced by ac electric field are estimated using modulation of reflected light. The electro-optic coefficients of PLZT ceramics measured with the aid of conventional birefringence using the phase shift of transmitted radiation and the proposed method of birefringence using the modulation of reflected light are compared.

  6. Common-path configuration in total internal reflection digital holography microscopy.

    Science.gov (United States)

    Calabuig, Alejandro; Matrecano, Marcella; Paturzo, Melania; Ferraro, Pietro

    2014-04-15

    Total Internal Reflection Digital Holographic Microscopy (TIRDHM) is recognized to be a powerful tool for retrieving quantitative phase images of cell-substrate interfaces, adhesions, and tissue structures close to the prism surface. In this Letter, we develop an improved TIRDHM system, taking advantage of a refractive index mismatch between the prism and the sample substrate, to allow phase-shifting DH with just a single-beam interferometric configuration. Instead of the traditional off-axis method, phase-shift method is used to retrieve amplitude and phase images in coherent light and TIR modality. Essentially, the substrate-prism interface acts like a beam splitter generating a reference beam, where the phase-shift dependence on the incident angle is exploited in this common-path configuration. With the aim to demonstrate the technique's validity, some experiments are performed to establish the advantage of this compact and simple configuration, in which the reference arm in the setup is avoided.

  7. Graphical Approach to Fresnel's Equations for Reflection and Refraction of Light.

    Science.gov (United States)

    Doyle, William T.

    1980-01-01

    Develops a coordinate-free approach to Fresnel's equations for the reflection and refraction of light at a plane interface. Describes a graphical construction for finding the vector amplitudes of the reflected and transmitted waves. (Author/CS)

  8. Microcavity-coupled fiber Bragg grating with tunable reflection spectra and speed of light.

    Science.gov (United States)

    Chen, Lei; Han, Ya; Liu, Qian; Liu, Yan-Ge; Zhang, Weigang; Chou, Keng C

    2018-04-15

    After a fiber Bragg grating (FBG) is fabricated, the reflection spectrum of the FBG is generally not tunable without mechanical deformation or temperature adjustment. Here we present a microcavity-coupled FBG with both a tunable reflection lineshape and dispersion using electromagnetically induced transparency. The Fano interference of light in the FBG and the microcavity allows for dramatic modification of the reflection spectrum. The phase of the reflected spectrum is continuously tunable between 0 and 2π to produce various Fano lineshapes. The dispersion of the output light is adjustable from normal dispersion to abnormal dispersion, consequently providing an adjustable speed of light. Additionally, it allows the FBG to switch from a notch filter to a bandpass filter at the resonant wavelength, which is not possible in a conventional uniform FBG.

  9. Refractive Index Imaging of Cells with Variable-Angle Near-Total Internal Reflection (TIR) Microscopy.

    Science.gov (United States)

    Bohannon, Kevin P; Holz, Ronald W; Axelrod, Daniel

    2017-10-01

    The refractive index in the interior of single cells affects the evanescent field depth in quantitative studies using total internal reflection (TIR) fluorescence, but often that index is not well known. We here present method to measure and spatially map the absolute index of refraction in a microscopic sample, by imaging a collimated light beam reflected from the substrate/buffer/cell interference at variable angles of incidence. Above the TIR critical angle (which is a strong function of refractive index), the reflection is 100%, but in the immediate sub-critical angle zone, the reflection intensity is a very strong ascending function of incidence angle. By analyzing the angular position of that edge at each location in the field of view, the local refractive index can be estimated. In addition, by analyzing the steepness of the edge, the distance-to-substrate can be determined. We apply the technique to liquid calibration samples, silica beads, cultured Chinese hamster ovary cells, and primary culture chromaffin cells. The optical technique suffers from decremented lateral resolution, scattering, and interference artifacts. However, it still provides reasonable results for both refractive index (~1.38) and for distance-to-substrate (~150 nm) for the cells, as well as a lateral resolution to about 1 µm.

  10. Tunable natural nano-arrays : controlling surface properties and light reflectance

    International Nuclear Information System (INIS)

    Watson, J.A.; Myhra, S.; Cribb, B.W.; Hope, G.A.; Watson, G.S.

    2005-01-01

    A sudden transition or impedance mismatch from one optical medium to another can result in unwanted reflections from the surface plane. Modification of a surface by creation of a gradual change in refractive index over a significant portion of a wavelength range will result in a reduction in reflection. Multi-layered thin film coatings based on this phenomenon are widely used on a number of different surfaces (e.g. solar cells, lenses, display screens etc.) to suppress undesired reflections and/or increase light transmittance. An alternative surface modification to the multi-layered stack coating (gradient index coating) is to produce a surface with structures having a period and heights shorter than the light wavelength. These structures act like a pseudo-gradient index coating and can be described by the effective medium theory. In this study we report on nano-structures (a natural pseudo-gradient index coating) which we have found on certain species of cicada wings demonstrating their reflective effectiveness using manipulative atomic force microscopy. (author). 2 refs., 5 figs

  11. Critical coupling of surface plasmons in graphene attenuated total reflection geometry

    Energy Technology Data Exchange (ETDEWEB)

    Cuevas, Mauro, E-mail: cuevas@df.uba.ar [Consejo Nacional de Investigaciones Científicas y Técnicas (CONICET) and Facultad de Ingeniería y Tecnología Informática, Universidad de Belgrano, Villanueva 1324, C1426BMJ, Buenos Aires (Argentina); Grupo de Electromagnetismo Aplicado, Departamento de Física, FCEN, Universidad de Buenos Aires and IFIBA, Ciudad Universitaria, Pabellón I, C1428EHA, Buenos Aires (Argentina)

    2016-12-09

    We study the optical response of an attenuated total reflection (ATR) structure in Otto configuration with graphene sheet, paying especial attention to the occurrence of total absorption. Our results show that due to excitation of surface plasmons on the graphene sheet, two different conditions of total absorption may occur. At these conditions, the energy loss of the surface plasmon by radiation is equal to its energy loss by absorption into the graphene sheet. We give necessary conditions on ATR parameters for the existence of total absorption. - Highlights: • Attenuated total reflection (ATR) structure with graphene sheet. • Surface plasmons and power matched condition. • Necessary conditions on ATR parameters for the existence of total absorption.

  12. Critical coupling of surface plasmons in graphene attenuated total reflection geometry

    International Nuclear Information System (INIS)

    Cuevas, Mauro

    2016-01-01

    We study the optical response of an attenuated total reflection (ATR) structure in Otto configuration with graphene sheet, paying especial attention to the occurrence of total absorption. Our results show that due to excitation of surface plasmons on the graphene sheet, two different conditions of total absorption may occur. At these conditions, the energy loss of the surface plasmon by radiation is equal to its energy loss by absorption into the graphene sheet. We give necessary conditions on ATR parameters for the existence of total absorption. - Highlights: • Attenuated total reflection (ATR) structure with graphene sheet. • Surface plasmons and power matched condition. • Necessary conditions on ATR parameters for the existence of total absorption.

  13. Total Reflection X-ray Fluorescence attachment module modified for analysis in vacuum

    International Nuclear Information System (INIS)

    Wobrauschek, P.; Streli, C.; Kregsamer, P.; Meirer, F.; Jokubonis, C.; Markowicz, A.; Wegrzynek, D.; Chinea-Cano, E.

    2008-01-01

    Based on the design of the low cost Total Reflection X-Ray Fluorescence attachment module available since 1986 from Atominstitut (WOBRAUSCHEK-module) which can be attached to existing X-ray equipment, a new version was developed which allows the analysis of samples in vacuum. This design was in particular possible as the Peltier cooled light weight Silicon Drift Detector is following all adjustment procedures for total reflection as angle rotation and linear motion. The detector is mounted through a vacuum feed and O-ring tightening to the small vacuum chamber. The standard 30 mm round quartz, Si-wafer or Plexiglas reflectors are used to carry the samples. The reflectors are placed on the reference plane with the dried sample down looking facing in about 0.5 mm distance the up looking detector window. The reflectors are resting on 3 steel balls defining precisely the reference plane for the adjustment procedure. As the rotation axis of the module is in the plane of the reflector surface, angle dependent experiments can be made to distinguish between film and particulate type contamination of samples. Operating with a Mo anode at 50 kV and 40 mA with a closely attached multilayer monochromator and using a 10 mm 2 KETEK silicon drift detector with 8 μm Be window, a sensitivity of 70 cps/ng for Rb was measured and detection limits of 2 pg were obtained

  14. ELiXIR—Solid-State Luminaire With Enhanced Light Extraction by Internal Reflection

    Science.gov (United States)

    Allen, Steven C.; Steckl, Andrew J.

    2007-06-01

    A phosphor-converted light-emitting diode (pcLED) luminaire featuring enhanced light extraction by internal reflection (ELiXIR) with efficacy of 60 lm/W producing 18 lumens of yellowish green light at 100 mA is presented. The luminaire consists of a commercial blue high power LED, a polymer hemispherical shell lens with interior phosphor coating, and planar aluminized reflector. High extraction efficiency of the phosphor-converted light is achieved by separating the phosphor from the LED and using internal reflection to steer the light away from lossy reflectors and the LED package and out of the device. At 10 and 500 mA, the luminaire produces 2.1 and 66 lumens with efficacies of 80 and 37 lm/W, respectively. Technological improvements over existing commercial LEDs, such as more efficient pcLED packages or, alternatively, higher efficiency green or yellow for color mixing, will be essential to achieving 150 200 lm/W solid-state lighting. Advances in both areas are demonstrated.

  15. New light on ion channel imaging by total internal reflection fluorescence (TIRF) microscopy.

    Science.gov (United States)

    Yamamura, Hisao; Suzuki, Yoshiaki; Imaizumi, Yuji

    2015-05-01

    Ion channels play pivotal roles in a wide variety of cellular functions; therefore, their physiological characteristics, pharmacological responses, and molecular structures have been extensively investigated. However, the mobility of an ion channel itself in the cell membrane has not been examined in as much detail. A total internal reflection fluorescence (TIRF) microscope allows fluorophores to be imaged in a restricted region within an evanescent field of less than 200 nm from the interface of the coverslip and plasma membrane in living cells. Thus the TIRF microscope is useful for selectively visualizing the plasmalemmal surface and subplasmalemmal zone. In this review, we focused on a single-molecule analysis of the dynamic movement of ion channels in the plasma membrane using TIRF microscopy. We also described two single-molecule imaging techniques under TIRF microscopy: fluorescence resonance energy transfer (FRET) for the identification of molecules that interact with ion channels, and subunit counting for the determination of subunit stoichiometry in a functional channel. TIRF imaging can also be used to analyze spatiotemporal Ca(2+) events in the subplasmalemma. Single-molecule analyses of ion channels and localized Ca(2+) signals based on TIRF imaging provide beneficial pharmacological and physiological information concerning the functions of ion channels. Copyright © 2015 The Authors. Production and hosting by Elsevier B.V. All rights reserved.

  16. Properties of light reflected from road signs in active imaging for driving safety

    Science.gov (United States)

    Halstuch, Aviran; Yitzhaky, Yitzhak

    2007-10-01

    Night-vision systems in vehicles are a new emerging technology. A crucial problem in active (illumination-based) systems is distortion of images by saturation and blooming, due to strong retro-reflections from road signs. In this work we quantified this phenomenon. We measured the Mueller matrices and the polarization state of the reflected light from three different types of road signs commonly used. Measurements of the reflected intensity were taken also with respect to the angle of reflection. We found that different types of signs have different reflection properties. It is concluded from our measurements that the optimal solution for attenuating the retro-reflected intensity is using a linear horizontal polarized light source and a linear vertical polarizer. Unfortunately, while the performance of this solution is good for two types of road signs, it is less efficient for the third sign type.

  17. Beer analysis by synchrotron radiation total reflection X-ray fluorescence (SR-TXRF)

    International Nuclear Information System (INIS)

    Moreira, Silvana; Vives, Ana Elisa S. de; Nascimento Filho, Virgilio F.; Zucchi, Orgheda L.D.A.

    2005-01-01

    In this work the concentrations of P, S, Cl, K, Ca, Mn, Fe, Zn and Br in twenty-nine brands of national and international beers were determined by Synchrotron Radiation Total Reflection X-Ray Fluorescence analysis (SR-TXRF). The results were compared with the limits established by the Brazilian Legislation and the nutritive values established by National Agricultural Library (NAL). The measurements were performed at the X-ray Fluorescence Beamline at Synchrotron Light Source Laboratory, in Campinas, Sao Paulo, Brazil, using a polychromatic beam for excitation. A small volume of 5 μL of sample beers containing just an internal standard, used to correct geometry effects, were analyzed without any pre-treatment. The measuring time was 100 s and the detection limits obtained varied from 1μg.L -1 for Mn and Fe to 15μg.L -1 for P. (author)

  18. Raman scattering and attenuated-total-reflection studies of surface-plasmon polaritons

    International Nuclear Information System (INIS)

    Kurosawa, K.; Pierce, R.M.; Ushioda, S.; Hemminger, J.C.

    1986-01-01

    We have made in situ measurements of attenuated total reflection (ATR) and Raman scattering from a layered structure consisting of a glass prism, a thin silver film, an MgF 2 spacer, and a liquid mixture whose refractive index is matched to that of MgF 2 . When the incident angle of the laser beam coincides with the ATR angle, the surface-plasmon polariton (SPP) of the silver film is excited resonantly and the Raman scattering intensity of the liquid shows a maximum. The same effect is observed at the frequency of the Stokes scattered light. By measuring the decrease of the Raman scattering intensity of the liquid with increase of the thickness of the MgF 2 spacer layer, we have determined the decay length (l/sub d/) of the SPP field into the liquid. The measured value of l/sub d/ = 1539 A agrees with the calculated value, 1534 A

  19. Robust reflective ghost imaging against different partially polarized thermal light

    Science.gov (United States)

    Li, Hong-Guo; Wang, Yan; Zhang, Rui-Xue; Zhang, De-Jian; Liu, Hong-Chao; Li, Zong-Guo; Xiong, Jun

    2018-03-01

    We theoretically study the influence of degree of polarization (DOP) of thermal light on the contrast-to-noise ratio (CNR) of the reflective ghost imaging (RGI), which is a novel and indirect imaging modality. An expression for the CNR of RGI with partially polarized thermal light is carefully derived, which suggests a weak dependence of CNR on the DOP, especially when the ratio of the object size to the speckle size of thermal light has a large value. Different from conventional imaging approaches, our work reveals that RGI is much more robust against the DOP of the light source, which thereby has advantages in practical applications, such as remote sensing.

  20. Reuse of the Reflective Light and the Recycle Heat Energy in Concentrated Photovoltaic System

    Directory of Open Access Journals (Sweden)

    Hsin-Chien Chen

    2013-01-01

    Full Text Available A complex solar unit with microcrystalline silicon solar cells placed around the centered GaAs triple junction solar cell has been proposed and carried out. With the same illumination area and intensity, the total resultant power shows that the excess microcrystalline silicon solar cells increase the total output power by 13.2% by absorbing the reflective light from the surface of optical collimators. Furthermore, reusing the residual heat energy generated from the above-mentioned mechanism helps to increase the output power by around 14.1%. This mechanism provides a simple method to enhance the utility rate of concentrated photovoltaic (CPV system. Such concept can be further applied to the aerospace industry and the development of more efficient CPV solar energy applications.

  1. Development of a total reflection X-ray fluorescence spectrometer for ...

    Indian Academy of Sciences (India)

    Unknown

    design and use of a peltier cooled solid state detector for energy dispersive detection. Alignment and ... X-ray beam at a glancing angle less than the critical angle at which total ... materials is < 1 so that external total reflection takes place at an ...

  2. Enhanced sensitivity to dielectric function and thickness of absorbing thin films by combining total internal reflection ellipsometry with standard ellipsometry and reflectometry

    Science.gov (United States)

    Lizana, A.; Foldyna, M.; Stchakovsky, M.; Georges, B.; Nicolas, D.; Garcia-Caurel, E.

    2013-03-01

    High sensitivity of spectroscopic ellipsometry and reflectometry for the characterization of thin films can strongly decrease when layers, typically metals, absorb a significant fraction of the light. In this paper, we propose a solution to overcome this drawback using total internal reflection ellipsometry (TIRE) and exciting a surface longitudinal wave: a plasmon-polariton. As in the attenuated total reflectance technique, TIRE exploits a minimum in the intensity of reflected transversal magnetic (TM) polarized light and enhances the sensitivity of standard methods to thicknesses of absorbing films. Samples under study were stacks of three films, ZnO : Al/Ag/ZnO : Al, deposited on glass substrates. The thickness of the silver layer varied from sample to sample. We performed measurements with a UV-visible phase-modulated ellipsometer, an IR Mueller ellipsometer and a UV-NIR reflectometer. We used the variance-covariance formalism to evaluate the sensitivity of the ellipsometric data to different parameters of the optical model. Results have shown that using TIRE doubled the sensitivity to the silver layer thickness when compared with the standard ellipsometry. Moreover, the thickness of the ZnO : Al layer below the silver layer can be reliably quantified, unlike for the fit of the standard ellipsometry data, which is limited by the absorption of the silver layer.

  3. Beer analysis by synchrotron radiation total reflection X-ray fluorescence (SR-TXRF)

    Energy Technology Data Exchange (ETDEWEB)

    Moreira, Silvana [Universidade Estadual de Campinas, SP (Brazil). Faculdade de Engenharia Civil, Arquitetura e Urbanismo. Dept. de Recursos Hidricos]. E-mail: silvana@fec.unicamp.br; Vives, Ana Elisa S. de [Universidade Metodista de Piracicaba (UNIMEP), Santa Barbara D' Oeste, SP (Brazil). Faculdade de Engenharia, Arquitetura e Urbanismo]. E-mail: aesvives@unimep.br; Nascimento Filho, Virgilio F. [Centro de Energia Nuclear na Agricultura (CENA), Piracicaba, SP (Brazil). Lab. de Instrumentacao Nuclear]. E-mail: virgilio@cena.usp.br; Zucchi, Orgheda L.D.A. [Sao Paulo Univ., Ribeirao Preto, SP (Brazil). Faculdade de Ciencias Farmaceuticas de Ribeirao Preto]. E-mail: olzucchi@fcfrp.usp.br

    2005-07-01

    In this work the concentrations of P, S, Cl, K, Ca, Mn, Fe, Zn and Br in twenty-nine brands of national and international beers were determined by Synchrotron Radiation Total Reflection X-Ray Fluorescence analysis (SR-TXRF). The results were compared with the limits established by the Brazilian Legislation and the nutritive values established by National Agricultural Library (NAL). The measurements were performed at the X-ray Fluorescence Beamline at Synchrotron Light Source Laboratory, in Campinas, Sao Paulo, Brazil, using a polychromatic beam for excitation. A small volume of 5 {mu}L of sample beers containing just an internal standard, used to correct geometry effects, were analyzed without any pre-treatment. The measuring time was 100 s and the detection limits obtained varied from 1{mu}g.L{sup -1} for Mn and Fe to 15{mu}g.L{sup -1} for P. (author)

  4. Analysis of archaeological ceramics by total-reflection X-ray fluorescence: Quantitative approaches

    International Nuclear Information System (INIS)

    Fernandez-Ruiz, R.; Garcia-Heras, M.

    2008-01-01

    This paper reports the quantitative methodologies developed for the compositional characterization of archaeological ceramics by total-reflection X-ray fluorescence at two levels. A first quantitative level which comprises an acid leaching procedure, and a second selective level, which seeks to increase the number of detectable elements by eliminating the iron present in the acid leaching procedure. Total-reflection X-ray fluorescence spectrometry has been compared, at a quantitative level, with Instrumental Neutron Activation Analysis in order to test its applicability to the study of this kind of materials. The combination of a solid chemical homogenization procedure previously reported with the quantitative methodologies here presented allows the total-reflection X-ray fluorescence to analyze 29 elements with acceptable analytical recoveries and accuracies

  5. Analysis of archaeological ceramics by total-reflection X-ray fluorescence: Quantitative approaches

    Energy Technology Data Exchange (ETDEWEB)

    Fernandez-Ruiz, R. [Servicio Interdepartamental de Investigacion, Facultad de Ciencias, Universidad Autonoma de Madrid, Modulo C-9, Laboratorio de TXRF, Crta. Colmenar, Km 15, Cantoblanco, E-28049, Madrid (Spain)], E-mail: ramon.fernandez@uam.es; Garcia-Heras, M. [Grupo de Arqueometria de Vidrios y Materiales Ceramicos, Instituto de Historia, Centro de Ciencias Humanas y Sociales, CSIC, C/ Albasanz, 26-28, 28037 Madrid (Spain)

    2008-09-15

    This paper reports the quantitative methodologies developed for the compositional characterization of archaeological ceramics by total-reflection X-ray fluorescence at two levels. A first quantitative level which comprises an acid leaching procedure, and a second selective level, which seeks to increase the number of detectable elements by eliminating the iron present in the acid leaching procedure. Total-reflection X-ray fluorescence spectrometry has been compared, at a quantitative level, with Instrumental Neutron Activation Analysis in order to test its applicability to the study of this kind of materials. The combination of a solid chemical homogenization procedure previously reported with the quantitative methodologies here presented allows the total-reflection X-ray fluorescence to analyze 29 elements with acceptable analytical recoveries and accuracies.

  6. Small-displacement sensing system based on multiple total internal reflections in heterodyne interferometry.

    Science.gov (United States)

    Wang, Shinn-Fwu; Chiu, Ming-Hung; Chen, Wei-Wu; Kao, Fu-Hsi; Chang, Rong-Seng

    2009-05-01

    A small-displacement sensing system based on multiple total internal reflections in heterodyne interferometry is proposed. In this paper, a small displacement can be obtained only by measuring the variation in phase difference between s- and p-polarization states for the total internal reflection effect. In order to improve the sensitivity, we increase the number of total internal reflections by using a parallelogram prism. The theoretical resolution of the method is better than 0.417 nm. The method has some merits, e.g., high resolution, high sensitivity, and real-time measurement. Also, its feasibility is demonstrated.

  7. Total internal reflection second-harmonic generation: probing the alkane water interface

    International Nuclear Information System (INIS)

    Conboy, J.C.; Daschbach, J.L.; Richmond, G.L.

    1994-01-01

    Total internal reflection Second-Harmonic Generation (SHG) has been used to study a series of neat n-alkane/water interfaces. Polarization and incident angular-dependent measurements of the SH response show good agreement with theoretical predictions. Analysis of the incident and polarization angular-dependent SH response allows for determination of the nonlinear optical properties of molecules comprising the interfacial region. Based on Kleinman symmetry, the measured surface nonlinear susceptibilities suggest a high degree of interfacial order for octane and decane with less order indicated by the odd carbon n-alkanes examined, heptane and nonane. The SH response in reflection and transmission has been measured under a Total Internal Reflection (TIR) of the fundamental. The measured nonlinear susceptibilities in each case are found to be identical. (orig.)

  8. Nonimaging light concentrator with uniform irradiance

    Science.gov (United States)

    Winston, Roland; Gee, Randy C.

    2003-04-01

    A nonimaging light concentrator system including a primary collector of light, an optical mixer disposed near the focal zone for collecting light from the primary collector, the optical mixer having a transparent entrance aperture, an internally reflective housing for substantially total internal reflection of light, a transparent exit aperture and an array of photovoltaic cells disposed near the transparent exit aperture.

  9. Reflection and transmission of light at periodic layered metamaterial films

    Science.gov (United States)

    Paul, Thomas; Menzel, Christoph; Śmigaj, Wojciech; Rockstuhl, Carsten; Lalanne, Philippe; Lederer, Falk

    2011-09-01

    The appropriate description of light scattering (transmission/reflection) at a bulky artificial medium, consisting of a sequence of functional metamaterial and natural material films, represents a major challenge in current theoretical nano-optics. Because in many relevant cases, in particular, in the optical domain, a metamaterial must not be described by an effective permittivity and permeability the usual Fresnel formalism cannot be applied. A reliable alternative consists in using a Bloch mode formalism known, e.g., from the theory of photonic crystals. It permits to split this complex issue into two more elementary ones, namely the study of light propagation in an infinitely extended metamaterial and the analysis of light scattering at interfaces between adjacent meta and natural materials. The first problem is routinely solved by calculating the relevant Bloch modes and their dispersion relations. The second task is more involved and represents the subject of the present study. It consists in using the general Bloch mode orthogonality to derive rigorous expressions for the reflection and transmission coefficients at an interface between two three-dimensional absorptive periodic media for arbitrary incidence. A considerable simplification can be achieved if only the fundamental Bloch modes of both media govern the scattering properties at the interface. If this approximation is valid, which depends on the longitudinal metamaterial period, the periodic metamaterial may be termed homogeneous. Only in this case the disentanglement of the fundamental modes of both media can be performed and the reflection/transmission coefficients can be expressed in terms of two impedances, each depending solely on the properties of the fundamental mode of the respective medium. In order to complement the picture, we apply the present formalism to the quite general problem of reflection/transmission at a metamaterial film sandwiched between a dissimilar metamaterial. This

  10. Spectral confocal reflection microscopy using a white light source

    Science.gov (United States)

    Booth, M.; Juškaitis, R.; Wilson, T.

    2008-08-01

    We present a reflection confocal microscope incorporating a white light supercontinuum source and spectral detection. The microscope provides images resolved spatially in three-dimensions, in addition to spectral resolution covering the wavelength range 450-650nm. Images and reflection spectra of artificial and natural specimens are presented, showing features that are not normally revealed in conventional microscopes or confocal microscopes using discrete line lasers. The specimens include thin film structures on semiconductor chips, iridescent structures in Papilio blumei butterfly scales, nacre from abalone shells and opal gemstones. Quantitative size and refractive index measurements of transparent beads are derived from spectral interference bands.

  11. Precise shape reconstruction by active pattern in total-internal-reflection-based tactile sensor.

    Science.gov (United States)

    Saga, Satoshi; Taira, Ryosuke; Deguchi, Koichiro

    2014-03-01

    We are developing a total-internal-reflection-based tactile sensor in which the shape is reconstructed using an optical reflection. This sensor consists of silicone rubber, an image pattern, and a camera. It reconstructs the shape of the sensor surface from an image of a pattern reflected at the inner sensor surface by total internal reflection. In this study, we propose precise real-time reconstruction by employing an optimization method. Furthermore, we propose to use active patterns. Deformation of the reflection image causes reconstruction errors. By controlling the image pattern, the sensor reconstructs the surface deformation more precisely. We implement the proposed optimization and active-pattern-based reconstruction methods in a reflection-based tactile sensor, and perform reconstruction experiments using the system. A precise deformation experiment confirms the linearity and precision of the reconstruction.

  12. An active one-particle microrheometer: incorporating magnetic tweezers to total internal reflection microscopy.

    Science.gov (United States)

    Gong, Xiangjun; Hua, Li; Wu, Chi; Ngai, To

    2013-03-01

    We present a novel microrheometer by incorporating magnetic tweezers in the total internal reflection microscopy (TIRM) that enables measuring of viscoelastic properties of materials near solid surface. An evanescent wave generated by a solid∕liquid interface in the TIRM is used as the incident light source in the microrheometer. When a probe particle (of a few micrometers diameter) moves near the interface, it can interact with the evanescent field and reflect its position with respect to the interface by the scattered light intensity. The exponential distance dependence of the evanescent field, on the one hand, makes this technique extremely sensitive to small changes from z-fluctuations of the probe (with a resolution of several nanometers), and on the other, it does not require imaging of the probe with high lateral resolution. Another distinct advantage is the high sensitivity in determining the z position of the probe in the absence of any labeling. The incorporated magnetic tweezers enable us to effectively manipulate the distance of the embedded particle from the interface either by a constant or an oscillatory force. The force ramp is easy to implement through a coil current ramp. In this way, the local viscous and elastic properties of a given system under different confinements can therefore be measured by resolving the near-surface particle motion. To test the feasibility of applying this microrheology to soft materials, we measured the viscoelastic properties of sucrose and poly(ethylene glycol) solutions and compared the results to bulk rheometry. In addition, we applied this technique in monitoring the structure and properties of deformable microgel particles near the flat surface.

  13. Reflectance dependence of polytetrafluoroethylene on thickness for xenon scintillation light

    Energy Technology Data Exchange (ETDEWEB)

    Haefner, J.; Neff, A.; Arthurs, M.; Batista, E.; Morton, D.; Okunawo, M.; Pushkin, K.; Sander, A. [Randall Laboratory of Physics, University of Michigan, Ann Arbor, MI 48109-1040 (United States); Stephenson, S. [Randall Laboratory of Physics, University of Michigan, Ann Arbor, MI 48109-1040 (United States); University of California Davis, Department of Physics, One Shields Ave., Davis, CA 95616 (United States); Wang, Y. [Randall Laboratory of Physics, University of Michigan, Ann Arbor, MI 48109-1040 (United States); Lorenzon, W., E-mail: lorenzon@umich.edu [Randall Laboratory of Physics, University of Michigan, Ann Arbor, MI 48109-1040 (United States)

    2017-06-01

    Many rare event searches including dark matter direct detection and neutrinoless double beta decay experiments take advantage of the high VUV reflective surfaces made from polytetrafluoroethylene (PTFE) reflector materials to achieve high light collection efficiency in their detectors. As the detectors have grown in size over the past decade, there has also been an increased need for ever thinner detector walls without significant loss in reflectance to reduce dead volumes around active noble liquids, outgassing, and potential backgrounds. We report on the experimental results to measure the dependence of the reflectance on thickness of two PTFE samples at wavelengths near 178 nm. No change in reflectance was observed as the wall thickness of a cylindrically shaped PTFE vessel immersed in liquid xenon was varied between 1 mm to 9.5 mm.

  14. Enhanced sensitivity to dielectric function and thickness of absorbing thin films by combining total internal reflection ellipsometry with standard ellipsometry and reflectometry

    International Nuclear Information System (INIS)

    Lizana, A; Foldyna, M; Garcia-Caurel, E; Stchakovsky, M; Georges, B; Nicolas, D

    2013-01-01

    High sensitivity of spectroscopic ellipsometry and reflectometry for the characterization of thin films can strongly decrease when layers, typically metals, absorb a significant fraction of the light. In this paper, we propose a solution to overcome this drawback using total internal reflection ellipsometry (TIRE) and exciting a surface longitudinal wave: a plasmon-polariton. As in the attenuated total reflectance technique, TIRE exploits a minimum in the intensity of reflected transversal magnetic (TM) polarized light and enhances the sensitivity of standard methods to thicknesses of absorbing films. Samples under study were stacks of three films, ZnO : Al/Ag/ZnO : Al, deposited on glass substrates. The thickness of the silver layer varied from sample to sample. We performed measurements with a UV–visible phase-modulated ellipsometer, an IR Mueller ellipsometer and a UV–NIR reflectometer. We used the variance–covariance formalism to evaluate the sensitivity of the ellipsometric data to different parameters of the optical model. Results have shown that using TIRE doubled the sensitivity to the silver layer thickness when compared with the standard ellipsometry. Moreover, the thickness of the ZnO : Al layer below the silver layer can be reliably quantified, unlike for the fit of the standard ellipsometry data, which is limited by the absorption of the silver layer. (paper)

  15. Reflection and transmission of polarized light by planetary atmospheres

    International Nuclear Information System (INIS)

    Rooij, W.A. de.

    1985-01-01

    In this thesis the reflection and transmission of sunlight by planetary atmospheres is studied, taking full account of the polarization of light. The atmospheres are treated as being locally plane-parallel, and are assumed to consist of a number of homogeneous layers, the lowest one being either a ground surface or a semi-infinite homogeneous layer. (Auth.)

  16. Light reflection by the cuticle of C. aurigans scarabs: a biological broadband reflector of left handed circularly polarized light

    Science.gov (United States)

    Libby, E.; Azofeifa, D. E.; Hernández-Jiménez, M.; Barboza-Aguilar, C.; Solís, A.; García-Aguilar, I.; Arce-Marenco, L.; Hernández, A.; Vargas, W. E.

    2014-08-01

    Measured reflection spectra from elytra of Chrysina aurigans scarabs are reported. They show a broad reflection band for wavelengths from 0.525 to 1.0 μm with a sequence of maxima and minima reflection values superimposed on a mean value of around 40% for the high reflection band. Different mechanisms contributing to the reflection spectra have been considered, with the dominant effect, reflection of left handed circularly polarized light, being produced by a laminated left handed twisted structure whose pitch changes with depth through the procuticle in a more complex way than that characterizing broad band circular polarizers based on cholesteric liquid crystals.

  17. Light reflection by the cuticle of C. aurigans scarabs: a biological broadband reflector of left handed circularly polarized light

    International Nuclear Information System (INIS)

    Libby, E; Azofeifa, D E; Hernández-Jiménez, M; García-Aguilar, I; Arce-Marenco, L; Hernández, A; Vargas, W E; Barboza-Aguilar, C; Solís, A

    2014-01-01

    Measured reflection spectra from elytra of Chrysina aurigans scarabs are reported. They show a broad reflection band for wavelengths from 0.525 to 1.0 μm with a sequence of maxima and minima reflection values superimposed on a mean value of around 40% for the high reflection band. Different mechanisms contributing to the reflection spectra have been considered, with the dominant effect, reflection of left handed circularly polarized light, being produced by a laminated left handed twisted structure whose pitch changes with depth through the procuticle in a more complex way than that characterizing broad band circular polarizers based on cholesteric liquid crystals. (fast track communication)

  18. Determination of sulphur with total reflection x-ray spectrometry

    International Nuclear Information System (INIS)

    Steinmeyer, S.; Kolbesen, B.O.

    2000-01-01

    The potential and limitations of total reflection x-ray spectrometry (TXRF) were tested for the quantitative determination of the light element sulphur in inorganic and biological samples. As representatives of inorganic samples alkali, transition metal, magnesium and aluminum sulphates were investigated. As biological samples the sulphur containing amino acid methionine and the pharmaceutical drug insulin were chosen. All measurements were performed on a TXRF-spectrometer EXTRA IIA (Atomika Instruments, Oberschleissheim/Germany) using tungsten L-radiation as the excitation tube. Various concentrations of all samples ranging from 20 mg/l to 0.5 mg/l were determined. In addition the surface topography and thickness of the dry residue of these samples were investigated with SEM and a thickness profilometer (Alpha-Step). The result show that the reliable determination of sulphur in sulphates depends on the cation involved. Alkali sulphates like Na 2 SO 4 , or K 2 SO 4 form bulky residues resulting in significant deviations of the recovery rate of sulphur. In this case the use of smoothing detergents like 1 % HF, 1 % malic acid and 2 % hydrazinhydrat was found to be necessary for accurate determination. The results for the biological samples agree well with the expected values. The investigations lead to the conclusion that TXRF combined with a proper samples preparation is well suited for the determination of sulphur in different samples with various concentrations and matrices. (author)

  19. Trace elements determination in red and white wines using total-reflection X-ray fluorescence

    International Nuclear Information System (INIS)

    Anjos, M.J.; Lopes, R.T.; Jesus, E.F.O. de; Moreira, S.; Barroso, R.C.; Castro, C.R.F.

    2003-01-01

    Several wines produced in different regions from south of Brazil and available in markets in Rio de Janeiro were analyzed for their contents of elements such as: P, S, Cl, Ca, Ti, Cr, Mn, Fe, Ni, Cu, Zn, Rb and Sr. Multi-element analysis was possible with simple sample preparation and subsequent analysis by total-reflection X-ray fluorescence using synchrotron radiation. The measurement was carried at the X-ray fluorescence beamline in the Synchrotron Light Source Laboratory in Campinas, Brazil. The levels of the various elements obtained were lower in the Brazilian wines than the values generally found in the literature. The present study indicates the capability of multi-element analysis for determining the contents of various elements present in wines coming from Brazil vineyards by using a simple, sensitive and precise method

  20. Forensic application of total reflection X-ray fluorescence spectrometry for elemental characterization of ink samples

    International Nuclear Information System (INIS)

    Dhara, Sangita; Misra, N.L.; Maind, S.D.; Kumar, Sanjukta A.; Chattopadhyay, N.; Aggarwal, S.K.

    2010-01-01

    The possibility of applying Total Reflection X-ray Fluorescence for qualitative and quantitative differentiation of documents printed with rare earth tagged and untagged inks has been explored in this paper. For qualitative differentiation, a very small amount of ink was loosened from the printed documents by smoothly rubbing with a new clean blade without destroying the manuscript. 50 μL of Milli-Q water was put on this loose powder, on the manuscript, and was agitated by sucking and releasing the suspension two to three times with the help of a micropipette. The resultant dispersion was deposited on quartz sample support for Total Reflection X-ray Fluorescence measurements. The Total Reflection X-ray Fluorescence spectrum of tagged and untagged inks could be clearly differentiated. In order to see the applicability of Total Reflection X-ray Fluorescence for quantitative determinations of rare earths and also to countercheck such determinations in ink samples, the amounts of rare earth in painted papers with single rare earth tagged inks were determined by digesting the painted paper in HNO 3 /HClO 4 , mixing this solution with the internal standard and recording their Total Reflection X-ray Fluorescence spectra after calibration of the instrument. The results thus obtained were compared with those obtained by Inductively Coupled Plasma Mass Spectrometry and were found in good agreement. The average precision of the Total Reflection X-ray Fluorescence determinations was 5.5% (1σ) and the average deviation of Total Reflection X-ray Fluorescence determined values with that of Inductively Coupled Plasma Mass Spectrometry was 7.3%. These studies have shown that Total Reflection X-ray Fluorescence offers a promising and potential application in forensic work of this nature.

  1. Forensic application of total reflection X-ray fluorescence spectrometry for elemental characterization of ink samples

    Energy Technology Data Exchange (ETDEWEB)

    Dhara, Sangita [Fuel Chemistry Division, Bhabha Atomic Research Centre, Mumbai 400 085 (India); Misra, N.L., E-mail: nlmisra@barc.gov.i [Fuel Chemistry Division, Bhabha Atomic Research Centre, Mumbai 400 085 (India); Maind, S.D. [NAA Unit of Central Forensic Science Laboratory Hyderabad at Analytical Chemistry Division, Bhabha Atomic Research Centre, Mumbai 400 085 (India); Kumar, Sanjukta A. [Analytical Chemistry Division, Bhabha Atomic Research Centre, Mumbai 400 085 (India); Chattopadhyay, N. [NAA Unit of Central Forensic Science Laboratory Hyderabad at Analytical Chemistry Division, Bhabha Atomic Research Centre, Mumbai 400 085 (India); Aggarwal, S.K. [Fuel Chemistry Division, Bhabha Atomic Research Centre, Mumbai 400 085 (India)

    2010-02-15

    The possibility of applying Total Reflection X-ray Fluorescence for qualitative and quantitative differentiation of documents printed with rare earth tagged and untagged inks has been explored in this paper. For qualitative differentiation, a very small amount of ink was loosened from the printed documents by smoothly rubbing with a new clean blade without destroying the manuscript. 50 muL of Milli-Q water was put on this loose powder, on the manuscript, and was agitated by sucking and releasing the suspension two to three times with the help of a micropipette. The resultant dispersion was deposited on quartz sample support for Total Reflection X-ray Fluorescence measurements. The Total Reflection X-ray Fluorescence spectrum of tagged and untagged inks could be clearly differentiated. In order to see the applicability of Total Reflection X-ray Fluorescence for quantitative determinations of rare earths and also to countercheck such determinations in ink samples, the amounts of rare earth in painted papers with single rare earth tagged inks were determined by digesting the painted paper in HNO{sub 3}/HClO{sub 4}, mixing this solution with the internal standard and recording their Total Reflection X-ray Fluorescence spectra after calibration of the instrument. The results thus obtained were compared with those obtained by Inductively Coupled Plasma Mass Spectrometry and were found in good agreement. The average precision of the Total Reflection X-ray Fluorescence determinations was 5.5% (1sigma) and the average deviation of Total Reflection X-ray Fluorescence determined values with that of Inductively Coupled Plasma Mass Spectrometry was 7.3%. These studies have shown that Total Reflection X-ray Fluorescence offers a promising and potential application in forensic work of this nature.

  2. Three-dimensional particle tracking in concave structures made by ultraviolet nanoimprint via total internal reflection fluorescence microscopy and refractive-index-matching method

    Science.gov (United States)

    Fujinami, Taku; Kigami, Hiroshi; Unno, Noriyuki; Taniguchi, Jun; Satake, Shin-ichi

    2018-03-01

    Total internal reflection fluorescence microscopy (TIRFM) is a promising method for measuring fluid flow close to a wall with nanoscale resolution in a process that is termed "multilayer nanoparticle image velocimetry" (MnPIV). TIRFM uses evanescent light that is generated on a substrate (typically a glass slide) by total internal reflection of light. Many researchers have previously studied x-y-z (3D) flows of water close to flat glass slides using MnPIV. On the other hand, a fluid flow close to a structured surface is also important. To measure flows of water near micro-patterns, we previously developed an MnPIV technique that uses a refractive-index-matching method. In previous study, the micropattern is made of a thermoplastic material with a refractive index that closely matches that of water. In this study, ultraviolet nanoimprint lithography was used for fabricating the appropriate micro-patterns because this technique can fabricate a pattern with a high resolution. As a result, we succeeded in performing MnPIV in water with a circular hole array pattern made by ultraviolet nanoimprint using a refractive-index-matching method. We believe that this technique will be helpful in elucidating fluid flows around microstructures.

  3. Proposed frustrated-total-reflection acoustic sensing method

    International Nuclear Information System (INIS)

    Hull, J.R.

    1981-01-01

    Modulation of electromagnetic energy transmission through a frustrated-total-reflection device by pressure-induced changes in the index of refraction is proposed for use as an acoustic detector. Maximum sensitivity occurs for angles of incidence near the critical angle. The minimum detectable pressure in air is limited by Brownian noise. Acoustic propagation losses and diffraction of the optical beam by the acoustic signal limit the minimum acoustic wavelength to lengths of the order of the spatial extent of the optical beam. The response time of the method is fast enough to follow individual acoustic waves

  4. SVBRDF-Invariant Shape and Reflectance Estimation from a Light-Field Camera.

    Science.gov (United States)

    Wang, Ting-Chun; Chandraker, Manmohan; Efros, Alexei A; Ramamoorthi, Ravi

    2018-03-01

    Light-field cameras have recently emerged as a powerful tool for one-shot passive 3D shape capture. However, obtaining the shape of glossy objects like metals or plastics remains challenging, since standard Lambertian cues like photo-consistency cannot be easily applied. In this paper, we derive a spatially-varying (SV)BRDF-invariant theory for recovering 3D shape and reflectance from light-field cameras. Our key theoretical insight is a novel analysis of diffuse plus single-lobe SVBRDFs under a light-field setup. We show that, although direct shape recovery is not possible, an equation relating depths and normals can still be derived. Using this equation, we then propose using a polynomial (quadratic) shape prior to resolve the shape ambiguity. Once shape is estimated, we also recover the reflectance. We present extensive synthetic data on the entire MERL BRDF dataset, as well as a number of real examples to validate the theory, where we simultaneously recover shape and BRDFs from a single image taken with a Lytro Illum camera.

  5. Particle Shape Characterization of Lunar Regolith using Reflected Light Microscopy

    Science.gov (United States)

    McCarty, C. B.; Garcia, G. C.; Rickman, D.

    2014-12-01

    Automated identification of particles in lunar thin sections is necessary for practical measurement of particle shape, void characterization, and quantitative characterization of sediment fabric. This may be done using image analysis, but several aspects of the lunar regolith make such automations difficult. For example, many of the particles are shattered; others are aggregates of smaller particles. Sieve sizes of the particles span 5 orders of magnitude. The physical thickness of a thin section, at a nominal 30 microns, is large compared to the size of many of the particles. Image acquisition modes, such as SEM and reflected light, while superior to transmitted light, still have significant ambiguity as to the volume being sampled. It is also desirable to have a technique that is inexpensive, not resource intensive, and analytically robust. To this end, we have developed an image acquisition and processing protocol that identifies and delineates resolvable particles on the front surface of a lunar thin section using a petrographic microscope in reflected light. For a polished thin section, a grid is defined covering the entire thin section. The grid defines discrete images taken with 20% overlap, minimizing the number of particles that intersect image boundaries. In reflected light mode, two images are acquired at each grid location, with a closed aperture diaphragm. One image, A, is focused precisely on the front surface of the thin section. The second image, B, is made after the stage is brought toward the objective lens just slightly. A bright fringe line, analogous to a Becke line, appears inside all transparent particles at the front surface of the section in the second image. The added light in the bright line corresponds to a deficit around the particles. Particle identification is done using ImageJ and uses multiple steps. A hybrid 5x5 median filter is used to make images Af and Bf. This primarily removes very small particles just below the front surface

  6. Design and simulation of reflect-array metasurfaces in the visible regime

    KAUST Repository

    Alrasheed, Salma; Di Fabrizio, Enzo M.

    2017-01-01

    gradient phase gap-surface plasmon metasurfaces that exhibit high conversion efficiency (up to ∼97% of total reflected light) to the anomalous reflection angle for blue, green, and red wavelengths at normal and oblique incidence, and where light

  7. [Correction of light refraction and reflection in medical transmission optical tomography].

    Science.gov (United States)

    Tereshchenko, S A; Potapov, D A

    2002-01-01

    The effects of light refraction and reflection on the quality of image reconstruction in medical transmission optical tomography of high-scattering media are considered. It has been first noted that light refraction not only distorts the geometric scheme of measurements, but may lead to the appearance of object areas that cannot be scanned. Some ways of decreasing the effect of refraction on the reconstruction of spatial distribution of the extinction coefficient are stated.

  8. Characterization of atmospheric aerosols using Synchroton radiation total reflection X-ray fluorescence and Fe K-edge total reflection X-ray fluorescence-X-ray absorption near-edge structure

    Energy Technology Data Exchange (ETDEWEB)

    Fittschen, U.E.A. [Department of Chemistry, University of Hamburg, Martin-Luther-King-Platz 6, 20146 Hamburg (Germany)], E-mail: ursula.fittschen@chemie.uni-hamburg.de; Meirer, F. [Atominstitut, Vienna University of Technology, Stadionallee 2, 1020 Wien (Austria)], E-mail: fmeirer@ati.ac.at; Streli, C. [Atominstitut, Vienna University of Technology, Stadionallee 2, 1020 Wien (Austria)], E-mail: streli@ati.ac.at; Wobrauschek, P. [Atominstitut, Vienna University of Technology, Stadionallee 2, 1020 Wien (Austria)], E-mail: wobi@ati.ac.at; Thiele, J. [Department of Chemistry, University of Hamburg, Martin-Luther-King-Platz 6, 20146 Hamburg (Germany)], E-mail: Julian.Thiele@gmx.de; Falkenberg, G. [Hamburger Synchrotronstrahlungslabor at Deutsches Elektronen-Synchrotron DESY, Notkestr. 85, 22603 Hamburg (Germany)], E-mail: falkenbe@mail.desy.de; Pepponi, G. [ITC-irst, Via Sommarive 18, 38050 Povo (Trento) (Italy)], E-mail: pepponi@itc.it

    2008-12-15

    In this study a new procedure using Synchrotron total reflection X-ray fluorescence (SR-TXRF) to characterize elemental amounts in atmospheric aerosols down to particle sizes of 0.015 um is presented. The procedure was thoroughly evaluated regarding bounce off effects and blank values. Additionally the potential of total reflection X-ray fluorescence-X-ray absorption near edge structure (SR-TXRF-XANES) for speciation of FeII/III down to amounts of 34 pg in aerosols which were collected for 1 h is shown. The aerosols were collected in the city of Hamburg with a low pressure Berner impactor on Si carriers covered with silicone over time periods of 60 and 20 min each. The particles were collected in four and ten size fractions of 10.0-8.0 {mu}m, 8.0-2.0 {mu}m, 2.0-0.13 {mu}m 0.13-0.015 {mu}m (aerodynamic particle size) and 15-30 nm, 30-60 nm, 60-130 nm, 130-250 nm, 250-500 nm, 0.5-1 {mu}m, 1-2 {mu}m, 2-4 {mu}m, 4-8 {mu}m, 8-16 {mu}m. Prior to the sampling 'bounce off' effects on Silicone and Vaseline coated Si carriers were studied with total reflection X-ray fluorescence. According to the results silicone coated carriers were chosen for the analysis. Additionally, blank levels originating from the sampling device and the calibration procedure were studied. Blank levels of Fe corresponded to 1-10% of Fe in the aerosol samples. Blank levels stemming from the internal standard were found to be negligible. The results from the Synchroton radiation total reflection X-ray fluorescence analysis of the aerosols showed that 20 min of sampling time gave still enough sample material for elemental determination of most elements. For the determination of the oxidation state of Fe in the aerosols different Fe salts were prepared as a reference from suspensions in isopropanol. The results from the Fe K-edge Synchroton radiation total reflection X-ray fluorescence-X-ray absorption near-edge structure analysis of the aerosol samples showed that mainly Fe(III) was present in

  9. Characterization of atmospheric aerosols using Synchroton radiation total reflection X-ray fluorescence and Fe K-edge total reflection X-ray fluorescence-X-ray absorption near-edge structure

    International Nuclear Information System (INIS)

    Fittschen, U.E.A.; Meirer, F.; Streli, C.; Wobrauschek, P.; Thiele, J.; Falkenberg, G.; Pepponi, G.

    2008-01-01

    In this study a new procedure using Synchrotron total reflection X-ray fluorescence (SR-TXRF) to characterize elemental amounts in atmospheric aerosols down to particle sizes of 0.015 um is presented. The procedure was thoroughly evaluated regarding bounce off effects and blank values. Additionally the potential of total reflection X-ray fluorescence-X-ray absorption near edge structure (SR-TXRF-XANES) for speciation of FeII/III down to amounts of 34 pg in aerosols which were collected for 1 h is shown. The aerosols were collected in the city of Hamburg with a low pressure Berner impactor on Si carriers covered with silicone over time periods of 60 and 20 min each. The particles were collected in four and ten size fractions of 10.0-8.0 μm, 8.0-2.0 μm, 2.0-0.13 μm 0.13-0.015 μm (aerodynamic particle size) and 15-30 nm, 30-60 nm, 60-130 nm, 130-250 nm, 250-500 nm, 0.5-1 μm, 1-2 μm, 2-4 μm, 4-8 μm, 8-16 μm. Prior to the sampling 'bounce off' effects on Silicone and Vaseline coated Si carriers were studied with total reflection X-ray fluorescence. According to the results silicone coated carriers were chosen for the analysis. Additionally, blank levels originating from the sampling device and the calibration procedure were studied. Blank levels of Fe corresponded to 1-10% of Fe in the aerosol samples. Blank levels stemming from the internal standard were found to be negligible. The results from the Synchroton radiation total reflection X-ray fluorescence analysis of the aerosols showed that 20 min of sampling time gave still enough sample material for elemental determination of most elements. For the determination of the oxidation state of Fe in the aerosols different Fe salts were prepared as a reference from suspensions in isopropanol. The results from the Fe K-edge Synchroton radiation total reflection X-ray fluorescence-X-ray absorption near-edge structure analysis of the aerosol samples showed that mainly Fe(III) was present in all particle size fractions

  10. Total internal reflection tomography of small objects

    International Nuclear Information System (INIS)

    Chen Xudong

    2008-01-01

    The multiple signal classification (MUSIC) imaging method is applied to determine the locations of a collection of small anisotropic spherical scatterers in the framework of the total internal reflection tomography. Multiple scattering between scatterers is considered and the inverse scattering problem is nonlinear, which, however, is solved by the proposed fast analytical approach where no associated forward problem is iteratively evaluated. The paper also discusses the role of the polarization of incidence waves, the incidence angle, the separation of scatterers from the surface of the substrate, and the level of noise on the resolution of imaging.

  11. Effects of bleaching agents on human enamel light reflectance.

    Science.gov (United States)

    Markovic, Ljubisa; Fotouhi, Kasra; Lorenz, Heribert; Jordan, Rainer A; Gaengler, Peter; Zimmer, Stefan

    2010-01-01

    Tooth whitening has been associated with splitting-up chromogenic molecules by hydrogen peroxides. Though micromorphological alterations are well documented, little is known about optical changes as a function of shifting in wavelengths. Therefore, the aim of the current study was to measure reflectance changes after bleaching in vitro by using a spectrometer. Forty-eight enamel slabs (diameter = 5 mm) were prepared from the sound enamel of extracted human teeth that were: 1) fully impacted, 2) from juveniles ages 10 to 16 years, 3) from adults 35 to 45 years of age and 4) from seniors older than age 65. In all specimens, the baseline total reflectance measurement was performed with a computer-assisted spectrometer (Ocean Optics, Dunedin, FL, USA) within wavelengths (wl) from 430 nm to 800 nm. Four enamel samples of each age group were exposed to either 10% or 15% carbamide peroxide (Illuminé Home, Dentsply, Konstanz, Germany) or 35% hydrogen peroxide (Pola Office, SDI Limited, Victoria, Australia). After surface treatment, all slabs underwent total reflectance measurement again. Statistical analysis was calculated at wl 450, 500 and 750 nm using the Student's paired t-test and one-way variance analysis. Total reflectance significantly increased after bleaching at all enamel maturation stages, irrespective of the bleaching agent concentration, for wl 450 nm (blue) and 500 nm (green) with penamel from adults and seniors (pwhitening of the dental enamel works at different maturation stages, even in impacted teeth. This effect is irrespective of the bleaching protocol used and the bleaching agent concentration.

  12. Production of a diffuse very high reflectivity material for light collection in nuclear detectors

    CERN Document Server

    Pichler, B J; Mirzoyan, R; Weiss, L; Ziegler, S I

    2000-01-01

    A diffuse very high reflectivity material, based on polytetrafluorethylene (PTFE) for optimization of light-collection efficiency has been developed. PTFE powder was used to produce reflector block material. The powder was pressed with 525 kPa in a form and sintered at 375 deg. C. The reflectivity was above 98% within the spectral range from 350 to 1000 nm. The blocks of this material are machinable with saws, drilling and milling machines. The reflector is used as a housing for scintillating crystals in a nuclear medicine application (small animal positron emission tomograph). It is also used as a light collector in very high-energy gamma-ray astrophysicas experiments, HEGRA and MAGIC. The application of this inexpensive, easy to make diffuse reflector may allow the optimization of light collection in a wide range of low-level light-detector configurations.

  13. Geometrically distributed one-dimensional photonic crystals for light-reflection in all angles.

    Science.gov (United States)

    Alagappan, G; Wu, P

    2009-07-06

    We demonstrate that a series of one-dimensional photonic crystals made of any dielectric materials, with the periods are distributed in a geometrical progression of a common ratio, r rc (theta,P), where rc is a structural parameter that depends on the angle of incidence, theta, and polarization, P, is capable of blocking light of any spectral range. If an omni-directional reflection is desired for all polarizations and for all incident angles smaller than thetao, then r rc (theta(o),p), where p is the polarization with the electric field parallel to the plane of incidence. We present simple and formula like expressions for rc, width of the bandgap, and minimum number of photonic crystals to achieve a perfect light reflection.

  14. Phototaxis and polarotaxis hand in hand: night dispersal flight of aquatic insects distracted synergistically by light intensity and reflection polarization

    Science.gov (United States)

    Boda, Pál; Horváth, Gábor; Kriska, György; Blahó, Miklós; Csabai, Zoltán

    2014-05-01

    Based on an earlier observation in the field, we hypothesized that light intensity and horizontally polarized reflected light may strongly influence the flight behaviour of night-active aquatic insects. We assumed that phototaxis and polarotaxis together have a more harmful effect on the dispersal flight of these insects than they would have separately. We tested this hypothesis in a multiple-choice field experiment using horizontal test surfaces laid on the ground. We offered simultaneously the following visual stimuli for aerial aquatic insects: (1) lamplit matte black canvas inducing phototaxis alone, (2) unlit shiny black plastic sheet eliciting polarotaxis alone, (3) lamplit shiny black plastic sheet inducing simultaneously phototaxis and polarotaxis, and (4) unlit matte black canvas as a visually unattractive control. The unlit matte black canvas trapped only a negligible number (13) of water insects. The sum (16,432) of the total numbers of water beetles and bugs captured on the lamplit matte black canvas (7,922) and the unlit shiny black plastic sheet (8,510) was much smaller than the total catch (29,682) caught on the lamplit shiny black plastic sheet. This provides experimental evidence for the synergistic interaction of phototaxis (elicited by the unpolarized direct lamplight) and polarotaxis (induced by the strongly and horizontally polarized plastic-reflected light) in the investigated aquatic insects. Thus, horizontally polarizing artificial lamplit surfaces can function as an effective ecological trap due to this synergism of optical cues, especially in the urban environment.

  15. Light propagation with phase discontinuities: generalized laws of reflection and refraction.

    Science.gov (United States)

    Yu, Nanfang; Genevet, Patrice; Kats, Mikhail A; Aieta, Francesco; Tetienne, Jean-Philippe; Capasso, Federico; Gaburro, Zeno

    2011-10-21

    Conventional optical components rely on gradual phase shifts accumulated during light propagation to shape light beams. New degrees of freedom are attained by introducing abrupt phase changes over the scale of the wavelength. A two-dimensional array of optical resonators with spatially varying phase response and subwavelength separation can imprint such phase discontinuities on propagating light as it traverses the interface between two media. Anomalous reflection and refraction phenomena are observed in this regime in optically thin arrays of metallic antennas on silicon with a linear phase variation along the interface, which are in excellent agreement with generalized laws derived from Fermat's principle. Phase discontinuities provide great flexibility in the design of light beams, as illustrated by the generation of optical vortices through use of planar designer metallic interfaces.

  16. The effect of surface texture on total reflection of neutrons and X-rays from modified interfaces

    DEFF Research Database (Denmark)

    Goldar, A.; Roser, S.J.; Hughes, A.

    2002-01-01

    X-ray and neutron scattering from macroscopically rough surfaces and interfaces is considered and a new method of analysis based on the variation of the shape of the total reflection edge in the reflectivity profile is proposed. It was shown that in the limit that the correlation length and the h......X-ray and neutron scattering from macroscopically rough surfaces and interfaces is considered and a new method of analysis based on the variation of the shape of the total reflection edge in the reflectivity profile is proposed. It was shown that in the limit that the correlation length...... and the height of the surface roughness are larger than the wavelength (at least 100 times bigger) of the incoming beam, the total reflection edge in the reflection profile becomes rounded. This technique allows direct analysis of the variation of the reflectivity pro le in terms of the structure of the surface...

  17. Total reflection x-ray fluorescence - an approach to nanoanalysis

    International Nuclear Information System (INIS)

    Klockenkaemper, R.

    2000-01-01

    X-ray fluorescence analysis (XRFA) is a powerful tool used for industrial production, geological prospecting and for environmental control. However, the method suffers from a lack of sensitivity so that analyses are restricted to microanalytical investigations. That means: the sample amount needed for analysis is above some 10 micrograms, concentrations to be determined have to be on the μg/ml level, and thin layers to be characterized must be of micrometer thickness. In contrast to conventional XRFA, total-reflection X-ray fluorescence (TXRF) is extremely sensitive and even allows nano-analytical investigations. Three different ways can be taken: (i) use of minute sample amounts of only 10 nano-grams, (ii) determination of extreme traces below ng/ml and (iii) surface analysis and depth profiling of shallow layers with nano-meter thickness. In this lecture, the basic physical phenomena of total reflection and standing waves are outlined. The experimental equipment for TXRF is sketched out and commercially available instruments of different manufacturers are compared. Furthermore, examples are given for the three kinds of nano-analytical applications: ultra-micro, analysis, ultra trace analysis and mono- and thin-layer analysis. (author)

  18. Sweeping total reflection X-ray fluorescence optimisation to monitor the metallic contamination into IC manufacturing

    International Nuclear Information System (INIS)

    Borde, Yannick; Danel, Adrien; Roche, Agnes; Veillerot, Marc

    2008-01-01

    Among the methods available on the market today to control as metallic contamination in integrated circuit manufacturing, Sweeping Total reflection X-ray Fluorescence mode appears a very good method, providing fast and entire wafer mapping. With the goal of a pertinent use of Sweeping Total reflection X-ray Fluorescence in advanced Integrated Circuit manufacturing this work discusses how acceptable levels of contamination specified by the production (low levels to be detected) can be taken into account. The relation between measurement results (surface coverage, throughput, low limit of detection, limit of quantification, quantification of localized contamination) and Sweeping Total reflection X-ray Fluorescence parameters (number of measurement points and integration time per point) is presented in details. In particular, a model is proposed to explain the mismatch between actual surface contamination in a localized spot on wafer and Total reflection X-ray Fluorescence reading. Both calibration and geometric issues have been taken into account

  19. Monte Carlo simulation of reflection spectra of random multilayer media strongly scattering and absorbing light

    International Nuclear Information System (INIS)

    Meglinskii, I V

    2001-01-01

    The reflection spectra of a multilayer random medium - the human skin - strongly scattering and absorbing light are numerically simulated. The propagation of light in the medium and the absorption spectra are simulated by the stochastic Monte Carlo method, which combines schemes for calculations of real photon trajectories and the statistical weight method. The model takes into account the inhomogeneous spatial distribution of blood vessels, water, and melanin, the degree of blood oxygenation, and the hematocrit index. The attenuation of the incident radiation caused by reflection and refraction at Fresnel boundaries of layers inside the medium is also considered. The simulated reflection spectra are compared with the experimental reflection spectra of the human skin. It is shown that a set of parameters that was used to describe the optical properties of skin layers and their possible variations, despite being far from complete, is nevertheless sufficient for the simulation of the reflection spectra of the human skin and their quantitative analysis. (laser applications and other topics in quantum electronics)

  20. Spectral and spatial properties of polarized light reflections from the arms of squid (Loligo pealeii) and cuttlefish (Sepia officinalis L.).

    Science.gov (United States)

    Chiou, Tsyr-Huei; Mäthger, Lydia M; Hanlon, Roger T; Cronin, Thomas W

    2007-10-01

    On every arm of cuttlefish and squid there is a stripe of high-reflectance iridophores that reflects highly polarized light. Since cephalopods possess polarization vision, it has been hypothesized that these polarized stripes could serve an intraspecific communication function. We determined how polarization changes when these boneless arms move. By measuring the spectral and polarizing properties of the reflected light from samples at various angles of tilt and rotation, we found that the actual posture of the arm has little or no effect on partial polarization or the e-vector angle of the reflected light. However, when the illumination angle changed, the partial polarization of the reflected light also changed. The spectral reflections of the signals were also affected by the angle of illumination but not by the orientation of the sample. Electron microscope samples showed that these stripes are composed of several groups of multilayer platelets within the iridophores. The surface normal to each group is oriented at a different angle, which produces essentially constant reflection of polarized light over a range of viewing angles. These results demonstrate that cuttlefish and squid could send out reliable polarization signals to a receiver regardless of arm orientation.

  1. Elemental concentration in normal skin and fibroepithelial polip lesions by synchrotron radiation total reflection X-ray fluorescence technique

    International Nuclear Information System (INIS)

    Soares, Julio C.A.C.R.; Canellas, Catarine G.L.; Lopes, Ricardo T.; Anjos, Marcelino J.

    2011-01-01

    In this work, the concentrations of trace elements were measured in acrochordon, a skin lesion also known as skin tag or fibroepithelial polyp, as well as in normal skin from the same patient. The samples were analysed by Synchrotron Radiation Total Reflection X- ray Fluorescence (SRTXRF) in the Synchrotron Light National Laboratory (LNLS) in Campinas/Sao Paulo-Brazil. The collection of lesion and healthy skin samples, including papillary dermis and epidermis, has involved 17 patients. It was evaluated the presence of P, S, Cl, K, Ca, Cr, Mn, Fe, Cu, Zn, Br and Rb in the paired samples, which were compared, and significant differences were found in some of them. (author)

  2. Synchrotron radiation total reflection for rainwater analysis

    International Nuclear Information System (INIS)

    Simabuco, Silvana M.; Matsumoto, Edson

    1999-01-01

    Total reflection X-ray fluorescence analysis excited with synchrotron radiation (SR-TXRF) has been used for rainwater trace element analysis. The samples were collected in four different sites at Campinas City, SP. Standard solutions with gallium as internal standard were prepared for the calibration system. Rainwater samples of 10 μl were putted onto Perspex reflector disk, dried on vacuum and analyzed for 100 s measuring time. The detection limits obtained for K-shell varied from 29 ng.ml -1 for sulfur to 1.3 ng.ml -1 for zinc and copper, while for L-shell the values were 4.5 ng.ml -1 for mercury and 7.0 ng.ml -1 for lead. (author)

  3. Design and simulation of reflect-array metasurfaces in the visible regime

    KAUST Repository

    Alrasheed, Salma

    2017-04-07

    Metasurfaces are new, promising ultrathin materials that can enable many novel optical devices due to their ability to act as a discontinuity interface that introduces an abrupt change in amplitude, phase, and sometimes the polarization of the incident light at the wavelength scale. Therefore they can function as flat optical elements. Here, we investigate the anomalous reflection of light for transverse-magnetic (TM) polarization for normal and oblique incidence in the visible regime. We propose gradient phase gap-surface plasmon metasurfaces that exhibit high conversion efficiency (up to ∼97% of total reflected light) to the anomalous reflection angle for blue, green, and red wavelengths at normal and oblique incidence, and where light polarization is unchanged after the reflection.

  4. Comparison of conventional and total reflection excitation geometry for fluorescence X-ray absorption spectroscopy on droplet samples

    International Nuclear Information System (INIS)

    Falkenberg, G.; Pepponi, G.; Streli, C.; Wobrauschek, P.

    2003-01-01

    X-ray absorption fine structure (XAFS) experiments in fluorescence mode have been performed in total reflection excitation geometry and conventional 45 deg. /45 deg. excitation/detection geometry for comparison. The experimental results have shown that XAFS measurements are feasible under normal total reflection X-ray fluorescence (TXRF) conditions, i.e. on droplet samples, with excitation in grazing incidence and using a TXRF experimental chamber. The application of the total reflection excitation geometry for XAFS measurements increases the sensitivity compared to the conventional geometry leading to lower accessible concentration ranges. However, XAFS under total reflection excitation condition fails for highly concentrated samples because of the self-absorption effect

  5. Intra-Cavity Total Reflection For High Sensitivity Measurement Of Optical Properties

    Science.gov (United States)

    Pipino, Andrew Charles Rule

    1999-11-16

    An optical cavity resonator device is provided for conducting sensitive murement of optical absorption by matter in any state with diffraction-limited spatial resolution through utilization of total internal reflection within a high-Q (high quality, low loss) optical cavity. Intracavity total reflection generates an evanescent wave that decays exponentially in space at a point external to the cavity, thereby providing a localized region where absorbing materials can be sensitively probed through alteration of the Q-factor of the otherwise isolated cavity. When a laser pulse is injected into the cavity and passes through the evanescent state, an amplitude loss resulting from absorption is incurred that reduces the lifetime of the pulse in the cavity. By monitoring the decay of the injected pulse, the absorption coefficient of manner within the evanescent wave region is accurately obtained from the decay time measurement.

  6. Characterizing Cool Giant Planets in Reflected Light

    Science.gov (United States)

    Marley, Mark

    2016-01-01

    While the James Webb Space Telescope will detect and characterize extrasolar planets by transit and direct imaging, a new generation of telescopes will be required to detect and characterize extrasolar planets by reflected light imaging. NASA's WFIRST space telescope, now in development, will image dozens of cool giant planets at optical wavelengths and will obtain spectra for several of the best and brightest targets. This mission will pave the way for the detection and characterization of terrestrial planets by the planned LUVOIR or HabEx space telescopes. In my presentation I will discuss the challenges that arise in the interpretation of direct imaging data and present the results of our group's effort to develop methods for maximizing the science yield from these planned missions.

  7. Attenuated total internal reflection infrared microscopy of multilayer plastic packaging foils.

    Science.gov (United States)

    van Dalen, Gerard; Heussen, Patricia C M; den Adel, Ruud; Hoeve, Robert B J

    2007-06-01

    Multilayer plastic foils are important packaging materials that are used to extend the shelf life of food products and drinks. Fourier transform infrared (FT-IR) spectroscopic imaging using attenuated total internal reflection (ATR) can be used for the identification and localization of different layers in multilayer foils. A new type of ATR crystal was used in combination with a linear array detector through which large sample areas (400 x 400 microm(2)) could be imaged with a pixel size of 1.6 microm. The method was tested on laminated plastic packing materials containing 5 to 12 layers. The results of the identification of the different materials using ATR-FT-IR were compared with differential scanning calorimetry (DSC) and the layer thickness of the individual layers measured by ATR-FT-IR was compared with polarized light microscopy (LM) and scanning electron microscopy (SEM). It has been demonstrated that individual layers with a thickness of about 3 microm could be identified in multilayer foils with a total thickness ranging from 100 to 150 microm. The results show a spatial resolution of about 4 microm (measured at wavenumbers ranging from 1000 to 1730 cm(-1)), which is about a factor of two better than can be obtained using transmission FT-IR imaging. An additional advantage of ATR is the ease of sample preparation. A good correspondence was found between visible and FT-IR images. The results of ATR-FT-IR imaging were in agreement with those obtained by LM, SEM, and DSC. ATR-FT-IR is superior to the combination of these techniques because it delivers both spatial and chemical information.

  8. Wavefronts, light rays and caustic of a circular wave reflected by an arbitrary smooth curve

    International Nuclear Information System (INIS)

    Marciano-Melchor, Magdalena; Silva-Ortigoza, Ramón; Montiel-Piña, Enrique; Román-Hernández, Edwin; Santiago-Santiago, José Guadalupe; Silva-Ortigoza, Gilberto; Rosado, Alfonso; Suárez-Xique, Román

    2011-01-01

    The aim of the present work is to obtain expressions for both the wavefront train and the caustic associated with the light rays reflected by an arbitrary smooth curve after being emitted by a point light source located at an arbitrary position in the two-dimensional free space. To this end, we obtain an expression for the k-function associated with the general integral of Stavroudis to the eikonal equation that describes the evolution of the reflected light rays. The caustic is computed by using the definitions of the critical and caustic sets of the two-dimensional map that describes the evolution of an arbitrary wavefront associated with the general integral. The general results are applied to circular and parabolic mirrors. The main motivation to carry out this research is to establish, in future work, the caustic touching theorem in a two-dimensional optical medium and to study the diffraction problem by using the k-function concept. Both problems are important in the computation of the image of an arbitrary object under reflection and refraction

  9. Method and apparatus for detecting phycocyanin-pigmented algae and bacteria from reflected light

    Science.gov (United States)

    Vincent, Robert (Inventor)

    2013-01-01

    The present invention relates to a method of detecting phycocyanin algae or bacteria in water from reflected light, and also includes devices for the measurement, calculation and transmission of data relating to that method.

  10. Diffuse Reflectance Spectroscopy for Total Carbon Analysis of Hawaiian Soils

    Science.gov (United States)

    McDowell, M. L.; Bruland, G. L.; Deenik, J. L.; Grunwald, S.; Uchida, R.

    2010-12-01

    Accurate assessment of total carbon (Ct) content is important for fertility and nutrient management of soils, as well as for carbon sequestration studies. The non-destructive analysis of soils by diffuse reflectance spectroscopy (DRS) is a potential supplement or alternative to the traditional time-consuming and costly combustion method of Ct analysis, especially in spatial or temporal studies where sample numbers are large. We investigate the use of the visible to near-infrared (VNIR) and mid-infrared (MIR) spectra of soils coupled with chemometric analysis to determine their Ct content. Our specific focus is on Hawaiian soils of agricultural importance. Though this technique has been introduced to the soil community, it has yet to be fully tested and used in practical applications for all soil types, and this is especially true for Hawaii. In short, DRS characterizes and differentiates materials based on the variation of the light reflected by a material at certain wavelengths. This spectrum is dependent on the material’s composition, structure, and physical state. Multivariate chemometric analysis unravels the information in a set of spectra that can help predict a property such as Ct. This study benefits from the remarkably diverse soils of Hawaii. Our sample set includes 216 soil samples from 145 pedons from the main Hawaiian Islands archived at the National Soil Survey Center in Lincoln, NE, along with more than 50 newly-collected samples from Kauai, Oahu, Molokai, and Maui. In total, over 90 series from 10 of the 12 soil orders are represented. The Ct values of these samples range from < 1% - 55%. We anticipate that the diverse nature of our sample set will ensure a model with applicability to a wide variety of soils, both in Hawaii and globally. We have measured the VNIR and MIR spectra of these samples and obtained their Ct values by dry combustion. Our initial analyses are conducted using only samples obtained from the Lincoln archive. In this

  11. Imaging the dorsal hippocampus: light reflectance relationships to electroencephalographic patterns during sleep

    DEFF Research Database (Denmark)

    Rector, D M; Poe, G R; Kristensen, Morten Pilgaard

    1995-01-01

    We assessed the correspondence of 660 nm light reflectance changes from the dorsal hippocampus with slow wave electroencephalographic (EEG) activity during quiet sleep (QS) and rapid eye movement (REM) sleep in four cats. An optic probe, attached to a charge-coupled-device (CCD) video camera...... as EEG changes. Dividing the image into 10 subregions revealed that reflectance changes at the rhythmical slow wave activity band (RSA, 4-6 Hz) persisted in localized regions during QS and REM sleep, but regional changes showed considerable wave-by-wave independence between areas and from slow wave...

  12. MCSLTT, Monte Carlo Simulation of Light Transport in Tissue

    International Nuclear Information System (INIS)

    2008-01-01

    Description of program or function: Understanding light-tissue interaction is fundamental in the field of Biomedical Optics. It has important implications for both therapeutic and diagnostic technologies. In this program, light transport in scattering tissue is modeled by absorption and scattering events as each photon travels through the tissue. The path of each photon is determined statistically by calculating probabilities of scattering and absorption. Other measured quantities are total reflected light, total transmitted light, and total heat absorbed

  13. Pressure-modulation dynamic attenuated-total-reflectance (ATR) FT-IR spectroscopy

    Science.gov (United States)

    Marcott, C.; Story, G. M.; Noda, I.; Bibby, A.; Manning, C. J.

    1998-06-01

    A single-reflectance attenuated-total-reflectance (ATR) accessory with a diamond internal-reflection element was modified by the addition of a piezoelectric transducer. Initial dynamic pressure-modulation experiments have been performed in the sample compartment of a step-scanning FT-IR spectrometer. A sinusoidal pressure modulation applied to samples of isotactic polypropylene and linear low density polyethylene resulted in dynamic responses which appear to be similar to those observed in previous dynamic 2D IR experiments. Preliminary pressure-modulation dynamic ATR results are also reported for a styrene-butadiene-styrene triblock copolymer. The new method has the advantages that a much wider variety of sample types and geometries can be studied and less sample preparation is required. Dynamic 2D IR experiments carried out by ATR no longer require thin films of large area and sufficient strength to withstand the dynamic strain applied by a rheometer. The ability to obtain dynamic IR spectroscopic information from a wider variety of sample types and thicknesses would greatly expand the amount of useful information that could be extracted from normally complicated, highly overlapped IR spectra.

  14. Cost effective flat plate photovoltaic modules using light trapping

    Science.gov (United States)

    Bain, C. N.; Gordon, B. A.; Knasel, T. M.; Malinowski, R. L.

    1981-01-01

    Work in optical trapping in 'thick films' is described to form a design guide for photovoltaic engineers. A thick optical film can trap light by diffusive reflection and total internal reflection. Light can be propagated reasonably long distances compared with layer thicknesses by this technique. This makes it possible to conduct light from inter-cell and intra-cell areas now not used in photovoltaic modules onto active cell areas.

  15. Position Detection Based on Intensities of Reflected Infrared Light

    DEFF Research Database (Denmark)

    Christensen, Henrik Vie

    measurements of reflected light intensities, and includes easy calibration. The method for reconstructing 3D positions has been implemented in a prototype of a “non-Touch Screen” for a computer, so that the user can control a cursor in three dimensions by moving his/hers hand in front of the computer screen....... The 2D position reconstruction method is mplemented in a prototype of a human-machine interface (HMI) for an electrically powered wheelchair, such that the wheelchair user can control the movement of the wheelchair by head movements. Both “non-Touch Screen” prototype and wheelchair HMI has been tested...

  16. Image analysis using reflected light: an underutilized tool for interpreting magnetic fabrics

    Science.gov (United States)

    Waters-Tormey, C. L.; Liner, T.; Miller, B.; Kelso, P. R.

    2010-12-01

    Grain shape fabric analysis is one of the most common tools used to compare magnetic fabric and handsample scale rock fabric. Usually, this image analysis uses photomicrographs taken under plane or polarized light, which may be problematic if there are several dominant magnetic carriers (e.g., magnetite and pyrrhotite). The method developed for this study uses reflected light photomicrographs, and is effective in assessing the relative contribution of different phases to the opaque mineral shape-preferred orientation (SPO). Mosaics of high-resolution photomicrographs are first assembled and processed in Adobe Photoshop®. The Adobe Illustrator® “Live Trace” tool, whose settings can be optimized for reflected light images, completes initial automatic grain tracing and phase separation. Checking and re-classification of phases using reflected light properties and trace editing occurs manually. Phase identification is confirmed by microprobe or quantitative EDS, after which grain traces are easily reclassified as needed. Traces are imported into SPO2003 (Launeau and Robin, 2005) for SPO analysis. The combination of image resolution and magnification used here includes grains down to 10 microns. This work is part of an ongoing study examining fabric development across strain gradients in the granulite facies Capricorn ridge shear zone exposed in the Mt. Hay block of central Australia (Waters-Tormey et al., 2009). Strain marker shape fabrics, mesoscale structures, and strain localization adjacent to major lithologic boundaries all indicate that the deformation involved flattening, but that components of the deformation have been partitioned into different lithological domains. Thin sections were taken from the two gabbroic map units which volumetrically dominate the shear zone (northern and southern) using samples with similar outcrop fabric intensity. Prior thermomagnetic analyses indicate these units contain magnetite ± titanomagnetite ± ilmenite ± pyrrhotite

  17. A new theory and its application to remove the effect of surface-reflected light in above-surface radiance data from clear and turbid waters

    International Nuclear Information System (INIS)

    Dev, Pravin Jeba; Shanmugam, Palanisamy

    2014-01-01

    Water-leaving radiances (L w ) measured from the deck of a ship or boat in oceanic and lake waters are widely and operationally used for satellite sensor vicarious calibration and validation and development of remote-sensing algorithms to understand interdisciplinary coastal ocean properties and processes. However, accurate determination of L w remains to be a challenging issue because of the limitations of the existing methods to accurately remove the undesired signal (surface-reflected light of the sky and sun) from above-surface measurements of the total upwelling radiance leaving the water surface. In this study, a new theory is developed and applied to the above-surface radiometric data measured from clear, turbid and eutrophic waters. The new method effectively removes surface-reflected contributions from the total upwelling radiance signal under different sky (clear sky to overcast sky) and sun glint conditions. The L w spectra obtained from the above-surface radiance data using the new method are found to match well with those extrapolated from the upwelling radiances (L u ) measured with another set of underwater radiometers (used just below the sea surface). The new method proves to be a viable alternative, especially in circumstances when the above-surface measurements of radiances are severally contaminated by the surface-reflected light fields. Since spectral radiance measurements are also sensitive to the observation angles, and to the magnitude of the radiometer's solid angle field of view, above-surface radiances are also measured for different viewing angles in highly eutrophic waters. Such measurements show large deviations in L w spectra except at lower viewing angles (30°). When applied to these data, the new method eliminates the undesired signal encountered at higher viewing angles and delivers accurate water-leaving radiance data. These results suggest that the new method is capable of removing the surface-reflected light fields from both

  18. Direct analysis of biological samples by total reflection X-ray fluorescence

    International Nuclear Information System (INIS)

    Lue M, Marco P.; Hernandez-Caraballo, Edwin A.

    2004-01-01

    The technique of total reflection X-ray fluorescence (TXRF) is well suited for the direct analysis of biological samples due to the low matrix interferences and simultaneous multi-element nature. Nevertheless, biological organic samples are frequently analysed after digestion procedures. The direct determination of analytes requires shorter analysis time, low reactive consumption and simplifies the whole analysis process. On the other hand, the biological/clinical samples are often available in minimal amounts and routine studies require the analysis of large number of samples. To overcome the difficulties associated with the analysis of organic samples, particularly of solid ones, different procedures of sample preparation and calibration to approach the direct analysis have been evaluated: (1) slurry sampling, (2) Compton peak standardization, (3) in situ microwave digestion, (4) in situ chemical modification and (5) direct analysis with internal standardization. Examples of analytical methods developed by our research group are discussed. Some of them have not been previously published, illustrating alternative strategies for coping with various problems that may be encountered in the direct analysis by total reflection X-ray fluorescence spectrometry

  19. A fiberoptic reflection oximeter.

    Science.gov (United States)

    Landsman, M L; Knop, N; Kwant, G; Mook, G A; Zijlstra, W G

    1978-03-20

    A catheter tip oximeter is described consisting of a cardiac catheter containing optical fibers, and incandescent light source, a light detection unit and a processing unit. Half of the optical fibers guide the light to the blood at the tip of the catheter, the other half the backscattered (reflected) light to the detection unit. The detection unit contains a dichroic mirror, transmitting most of the light with lambda less than 800 nm and reflecting most of the light with lambda greater than 900 nm, thus splitting the light into two beams. These pass through interference filters with nominal wavelengths of 640 and 920 nm respectively, and are focused on silicium barrier layer photocells. The photocell signals are amplified and fed into a divider giving the ratio of measuring (R640) and compensating (R920) photocell output. The relationship between log R640/R920 and oxygen saturation is represented by a slightly curved line. The relation may be linearized by subtracting a constant voltage from the divided output before taking the logarithm. The slope of the calibration line is dependent on the total haemoglobin concentration. Nonetheless an average calibration line can be used between 70 and 100% oxygen saturation. For 78 measurements of pig blood samples in this range (haemoglobin concentration between 96 and 161 g.1(-1)), the standard deviation of the difference between the fiberoptic oximeter and a Radiometer OSM1 oxygen saturation meter was 1.9% saturation, for 152 samples over the entire saturation range the standard deviation of the difference was 3.1% saturation. The influence of the flow velocity of blood on the light reflection depends on wavelength as well as on oxygen saturation. Therefore, complete compensation for the flow effect is not possible by simple means.

  20. Microanalysis of old violin varnishes by total-reflection X-ray fluorescence

    Science.gov (United States)

    von Bohlen, Alex; Meyer, Friedrich

    1997-07-01

    Total reflection X-ray fluorescence was used to characterize elements (with Z>13) contained in varnishes applied by prominent violin makers during the last five centuries. Direct analyses of small flakes with masses varnish. Higher amounts of Fe, As and Pb were found in old products, Mn, Co, Cu, Zn and Pb were used in more recent varnishes.

  1. Abstracts of the 8th Conference on total reflection x-ray fluorescence analysis and related methods

    International Nuclear Information System (INIS)

    Wobrauschek, P.

    2000-01-01

    The 8. conference on total reflection x-ray fluorescence analysis and related methods held from 25.9 to 29.9.2000 contains 79 abstracts about x-ray fluorescence analysis (XRFA) as a powerful tool used for industrial production, geological prospecting and for environmental control. Total reflection x-ray fluorescence spectroscopy is also a tool used for chemical analysis in medicine, industry and research. (E.B.)

  2. Total reflection coefficients of low-energy photons presented as universal functions

    Directory of Open Access Journals (Sweden)

    Ljubenov Vladan

    2010-01-01

    Full Text Available The possibility of expressing the total particle and energy reflection coefficients of low-energy photons in the form of universal functions valid for different shielding materials is investigated in this paper. The analysis is based on the results of Monte Carlo simulations of photon reflection by using MCNP, FOTELP, and PENELOPE codes. The normal incidence of the narrow monoenergetic photon beam of the unit intensity and of initial energies from 20 keV up to 100 keV is considered, and particle and energy reflection coefficients from the plane homogenous targets of water, aluminum, and iron are determined and compared. The representations of albedo coefficients on the initial photon energy, on the probability of large-angle photon scattering, and on the mean number of photon scatterings are examined. It is found out that only the rescaled albedo coefficients dependent on the mean number of photon scatterings have the form of universal functions and these functions are determined by applying the least square method.

  3. Springs-neaps cycles in daily total seabed light: Daylength-induced changes

    Science.gov (United States)

    Roberts, E. M.; Bowers, D. G.; Davies, A. J.

    2014-04-01

    In shallow, tidal seas, daily total seabed light is determined largely by the interaction of the solar elevation cycle, the tidal cycle in water depth, and any temporal variability in turbidity. Since tidal range, times of low water, and often turbidity vary in regular ways over the springs-neaps cycle, daily total seabed light exhibits cycles of the same periodicity. Corresponding cycles are likely to be induced in the daily total primary production of benthic algae and plants, particularly those light-limited specimens occupying the lower reaches of a sub-tidal population. Consequently, this effect is an important control on the growth patterns, depth distribution and survival of, for example, macroalgal forests and seagrass meadows. Seasonal changes in daylength exert an important additional control on these cycles, as they alter the fraction of the tidal and turbidity cycles occurring within daylight hours. Bowers et al. (1997) modelled this phenomenon numerically and predicted that for a site with low water at about midday and midnight at neaps tides, 6 am and 6 pm at springs, daily total seabed light peaks at neaps in winter, but the ‘sense' of the cycle ‘switches' so that it peaks at springs in summer - the longer daylength permits the morning and evening low water springs to contribute substantially to the daily total. Observations for such a site in North Wales (UK), presented in this paper, show that no such ‘switch' occurs, and neaps tides host the largest daily totals throughout the year. The predicted ‘switch' is not observed because turbidity increases generally at spring tides, and specifically at low water springs, both of which were not accounted for in the model. Observations at a second site in Brittany (France), diametrically opposite in terms of the times of low water at neaps and at springs, indicate a peak at springs throughout the year. Analytical tools are developed to calculate the percentage of daily total sea surface irradiance

  4. LightLeaves: computer controlled kinetic reflection hologram installation and a brief discussion of earlier work

    International Nuclear Information System (INIS)

    Connors Chen, Betsy

    2013-01-01

    LightLeaves is an installation combining leaf shaped, white light reflection holograms of landscape images with a special kinetic lighting device that houses a lamp and moving leaf shaped masks. The masks are controlled by an Arduino microcontroller and servomotors that position the masks in front of the illumination source of the holograms. The work is the most recent in a long series of landscapes that combine multi-hologram installations with computer controlled devices that play with the motion of the holograms, the light, sound or other elements in the work. LightLeaves was first exhibited at the Peabody Essex Museum in Salem, Massachusetts in a show titled E ye Spy: Playing with Perception .

  5. LightLeaves: computer controlled kinetic reflection hologram installation and a brief discussion of earlier work

    Energy Technology Data Exchange (ETDEWEB)

    Connors Chen, Betsy, E-mail: acmeholo@gmail.com [ACME Holography, Somerville, Massachusetts USA 02144 (United States)

    2013-02-22

    LightLeaves is an installation combining leaf shaped, white light reflection holograms of landscape images with a special kinetic lighting device that houses a lamp and moving leaf shaped masks. The masks are controlled by an Arduino microcontroller and servomotors that position the masks in front of the illumination source of the holograms. The work is the most recent in a long series of landscapes that combine multi-hologram installations with computer controlled devices that play with the motion of the holograms, the light, sound or other elements in the work. LightLeaves was first exhibited at the Peabody Essex Museum in Salem, Massachusetts in a show titled {sup E}ye Spy: Playing with Perception{sup .}.

  6. Superradiance or total reflection?

    CERN Document Server

    László, András

    2014-01-01

    Numerical evolution of massless scalar fields on Kerr background is studied. The initial data specifications are chosen to have compact support separated from the ergoregion and to yield nearly monochromatic incident wave packets. The initial data is also tuned to maximize the effect of superradiance. Evidences are shown indicating that instead of the anticipated energy extraction from black hole the incident radiation fail to reach the ergoregion rather it suffers a nearly perfect reflection.

  7. Elemental concentration analysis in prostate tissues using total reflection X-ray fluorescence

    International Nuclear Information System (INIS)

    Leitão, R.G.; Palumbo, A.; Souza, P.A.V.R.; Pereira, G.R.; Canellas, C.G.L.; Anjos, M.J.; Nasciutti, L.E.; Lopes, R.T.

    2014-01-01

    Prostate cancer (PCa) currently represents the second most prevalent malignant neoplasia in men, representing 21% of all cancer cases. Benign Prostate Hyperplasia (BPH) is an illness prevailing in men above the age of 50, close to 90% after the age of 80. The prostate presents a high zinc concentration, about 10-fold higher than any other body tissue. In this work, samples of human prostate tissues with cancer, BPH and normal tissue were analyzed utilizing total reflection X-ray fluorescence spectroscopy using synchrotron radiation technique (SR-TXRF) to investigate the differences in the elemental concentrations in these tissues. SR-TXRF analyses were performed at the X-ray fluorescence beamline at Brazilian National Synchrotron Light Laboratory (LNLS), in Campinas, São Paulo. It was possible to determine the concentrations of the following elements: P, S, K, Ca, Fe, Cu, Zn and Rb. By using Mann–Whitney U test it was observed that almost all elements presented concentrations with significant differences (α=0.05) between the groups studied. - Highlights: ► Prostate cancer is the most frequently diagnosed form of cancer in men. ► Intracellular Zn is correlated with proliferation, differentiation, or apoptosis. ► The prostate gland accumulate high concentration of Zn. ► SR-TXRF is a technique widely used in the analysis of low concentration in samples

  8. Total reflection and cloaking by zero index metamaterials loaded with rectangular dielectric defects

    KAUST Repository

    Wu, Ying

    2013-05-06

    In this work, we investigate wave transmission property through a zero index metamaterial (ZIM) waveguide embedded with rectangular dielectric defects. We show that total reflection and total transmission (cloaking) can be achieved by adjusting the geometric sizes and/or permittivities of the defects. Our work provides another possibility of manipulating wave propagation through ZIM in addition to the widely studied dielectric defects with cylindrical geometries.

  9. Total reflection and cloaking by zero index metamaterials loaded with rectangular dielectric defects

    KAUST Repository

    Wu, Ying; Li, Jichun

    2013-01-01

    In this work, we investigate wave transmission property through a zero index metamaterial (ZIM) waveguide embedded with rectangular dielectric defects. We show that total reflection and total transmission (cloaking) can be achieved by adjusting the geometric sizes and/or permittivities of the defects. Our work provides another possibility of manipulating wave propagation through ZIM in addition to the widely studied dielectric defects with cylindrical geometries.

  10. Intraocular light scatter, reflections, fluorescence and absorption: what we see in the slit lamp.

    Science.gov (United States)

    van den Berg, Thomas J T P

    2018-01-01

    Much knowledge has been collected over the past 20 years about light scattering in the eye- in particular in the eye lens- and its visual effect, called straylight. It is the purpose of this review to discuss how these insights can be applied to understanding the slit lamp image. The slit lamp image mainly results from back scattering, whereas the effects on vision result mainly from forward scatter. Forward scatter originates from particles of about wavelength size distributed throughout the lens. Most of the slit lamp image originates from small particle scatter (Rayleigh scatter). For a population of middle aged lenses it will be shown that both these scatter components remove around 10% of the light from the direct beam. For slit lamp observation close to the reflection angles, zones of discontinuity (Wasserspalten) at anterior and posterior parts of the lens show up as rough surface reflections. All these light scatter effects increase with age, but the correlations with age, and also between the different components, are weak. For retro-illumination imaging it will be argued that the density or opacity seen in areas of cortical or posterior subcapsular cataract show up because of light scattering, not because of light loss. NOTES: (1) Light scatter must not be confused with aberrations. Light penetrating the eye is divided into two parts: a relatively small part is scattered, and removed from the direct beam. Most of the light is not scattered, but continues as the direct beam. This non-scattered part is the basis for functional imaging, but its quality is under the control of aberrations. Aberrations deflect light mainly over small angles (light scatter is important because of the straylight effects over large angles (>1°), causing problems like glare and hazy vision. (2) The slit lamp image in older lenses and nuclear cataract is strongly influenced by absorption. However, this effect is greatly exaggerated by the light path lengths concerned. This

  11. Superresolution confocal technology for displacement measurements based on total internal reflection

    International Nuclear Information System (INIS)

    Kuang Cuifang; Hao Xiang; Wang Tingting; Liu Xu; Ali, M. Yakut

    2010-01-01

    In order to achieve a higher axial resolution for displacement measurement, a novel method is proposed based on total internal reflection filter and confocal microscope principle. A theoretical analysis of the basic measurement principles is presented. The analysis reveals that the proposed confocal detection scheme is effective in enhancing the resolution of nonlinearity of the reflectance curve greatly. In addition, a simple prototype system has been developed based on the theoretical analysis and a series of experiments have been performed under laboratory conditions to verify the system feasibility, accuracy, and stability. The experimental results demonstrate that the axial resolution in displacement measurements is better than 1 nm in a range of 200 nm which is threefold better than that can be achieved using the plane reflector.

  12. Superresolution confocal technology for displacement measurements based on total internal reflection.

    Science.gov (United States)

    Kuang, Cuifang; Ali, M Yakut; Hao, Xiang; Wang, Tingting; Liu, Xu

    2010-10-01

    In order to achieve a higher axial resolution for displacement measurement, a novel method is proposed based on total internal reflection filter and confocal microscope principle. A theoretical analysis of the basic measurement principles is presented. The analysis reveals that the proposed confocal detection scheme is effective in enhancing the resolution of nonlinearity of the reflectance curve greatly. In addition, a simple prototype system has been developed based on the theoretical analysis and a series of experiments have been performed under laboratory conditions to verify the system feasibility, accuracy, and stability. The experimental results demonstrate that the axial resolution in displacement measurements is better than 1 nm in a range of 200 nm which is threefold better than that can be achieved using the plane reflector.

  13. Evaluation of light scattering properties and chromophore concentrations in skin tissue based on diffuse reflectance signals at isosbestic wavelengths of hemoglobin

    Science.gov (United States)

    Yokokawa, Takumi; Nishidate, Izumi

    2016-04-01

    We investigate a method to evaluate light-scattering properties and chromophore concentrations in human skin tissue through diffuse reflectance spectroscopy using the reflectance signals acquired at isosbestic wavelengths of hemoglobin (420, 450, 500, and 585 nm). In the proposed method, Monte Carlo simulation-based empirical formulas are used to specify the scattering parameters of skin tissue, such as the scattering amplitude a and the scattering power b, as well as the concentration of melanin C m and the total blood concentration C tb. The use of isosbestic wavelengths of hemoglobin enables the values of C m, C tb, a, and b to be estimated independently of the oxygenation of hemoglobin. The spectrum of the reduced scattering coefficient is reconstructed from the scattering parameters. Experiments using in vivo human skin tissues were performed to confirm the feasibility of the proposed method for evaluating the changes in scattering properties and chromophore concentrations in skin tissue. The experimental results revealed that light scattering is significantly reduced by the application of a glycerol solution, which indicates an optical clearing effect due to osmotic dehydration and the matching of the refractive indices of scatterers in the epidermis.

  14. Light polarization management via reflection from arrays of sub-wavelength metallic twisted bands

    Science.gov (United States)

    Nawrot, M.; Haberko, J.; Zinkiewicz, Ł.; Wasylczyk, P.

    2017-12-01

    With constant progress of nano- and microfabrication technologies, photolithography in particular, a number of sub-wavelength metallic structures have been demonstrated that can be used to manipulate light polarization. Numerical simulations of light propagation hint that helical twisted bands can have interesting polarization properties. We use three-dimensional two-photon photolithography (direct laser writing) to fabricate a few-micrometer-thick arrays of twisted bands and coat them uniformly with metal. We demonstrate that circular polarization can be generated from linear polarization upon reflection from such structures over a broad range of frequencies in the mid infrared.

  15. Energy dispersive X-ray fluorescence analysis with multiple total reflection

    International Nuclear Information System (INIS)

    Freitag, K.

    1985-01-01

    The development of a total reflection XRF analyzer and the performance data of this instrument are described. The drastic reduction of the scattered radiation is the outstanding property of the method. Detection limits of elements and matrix effects are discussed. The competition with other methods of analysis has proven its advantages in a wide range. In addition to its multi-element features down to the picogram level, particularly its universal calibration function has turned out to be a great help in the analytical practice. (orig./RB)

  16. Development of off-line layer chromatographic and total reflection X-ray fluorescence spectrometric methods for arsenic speciation

    International Nuclear Information System (INIS)

    Mihucz, Victor G.; Moricz, Agnes M.; Kroepfl, Krisztina; Szikora, Szilvia; Tatar, Eniko; Parra, Lue Meru Marco; Zaray, Gyula

    2006-01-01

    Rapid and low cost off-line thin layer chromatography-total reflection X-ray fluorescence spectrometry and overpressured thin layer chromatography-total reflection X-ray fluorescence spectrometry methods have been developed for separation of 25 ng of each As(III), As(V), monomethyl arsonic acid and dimethylarsinic acid applying a PEI cellulose stationary phase on plastic sheets and a mixture of acetone/acetic acid/water = 2:1:1 (v/v/v) as eluent system. The type of eluent systems, the amounts (25-1000 ng) of As species applied to PEI cellulose plates, injection volume, development distance, and flow rate (in case of overpressured thin layer chromatography) were taken into consideration for the development of the chromatographic separation. Moreover, a microdigestion method employing nitric acid for the As spots containing PEI cellulose scratched from the developed plates divided into segments was developed for the subsequent total reflection X-ray fluorescence spectrometry analysis. The method was applied for analysis of root extracts of cucumber plants grown in As(III) containing modified Hoagland nutrient solution. Both As(III) and As(V) were detected by applying the proposed thin layer chromatography/overpressured thin layer chromatography-total reflection X-ray fluorescence spectrometry methods

  17. Development of off-line layer chromatographic and total reflection X-ray fluorescence spectrometric methods for arsenic speciation

    Energy Technology Data Exchange (ETDEWEB)

    Mihucz, Victor G. [Joint Research Group of Environmental Chemistry of Hungarian Academy of Sciences and L. Eoetvoes University, P. O. Box 32, H-1518 Budapest (Hungary); Hungarian Satellite Centre of Trace Elements Institute to UNESCO, P. O. Box 32, H-1518 Budapest (Hungary); Moricz, Agnes M. [L. Eoetvoes University, Department of Chemical Technology and Environmental Chemistry, P.O. Box 32, H-1518 Budapest (Hungary); Kroepfl, Krisztina [Joint Research Group of Environmental Chemistry of Hungarian Academy of Sciences and L. Eoetvoes University, P. O. Box 32, H-1518 Budapest (Hungary); Szikora, Szilvia [Joint Research Group of Environmental Chemistry of Hungarian Academy of Sciences and L. Eoetvoes University, P. O. Box 32, H-1518 Budapest (Hungary); Tatar, Eniko [Hungarian Satellite Centre of Trace Elements Institute to UNESCO, P. O. Box 32, H-1518 Budapest (Hungary); L. Eoetvoes University, Department of Inorganic and Analytical Chemistry, P.O. Box 32, H-1518 Budapest (Hungary); Parra, Lue Meru Marco [Universidad Centro-occidental Lisandro Alvarado, Decanato de Agronomia, Departamento de Quimica y Suelos Unidad de Analisis Instrumental, Apartado Postal 4076, Cabudare 3023 (Venezuela); Zaray, Gyula [Joint Research Group of Environmental Chemistry of Hungarian Academy of Sciences and L. Eoetvoes University, P. O. Box 32, H-1518 Budapest (Hungary) and Hungarian Satellite Centre of Trace Elements Institute to UNESCO, P. O. Box 32, H-1518 Budapest (Hungary) and L. Eoetvoes University, Department of Inorganic and Analytical Chemistry, P.O. Box 32, H-1518 Budapest (Hungary)]. E-mail: zaray@ludens.elte.hu

    2006-11-15

    Rapid and low cost off-line thin layer chromatography-total reflection X-ray fluorescence spectrometry and overpressured thin layer chromatography-total reflection X-ray fluorescence spectrometry methods have been developed for separation of 25 ng of each As(III), As(V), monomethyl arsonic acid and dimethylarsinic acid applying a PEI cellulose stationary phase on plastic sheets and a mixture of acetone/acetic acid/water = 2:1:1 (v/v/v) as eluent system. The type of eluent systems, the amounts (25-1000 ng) of As species applied to PEI cellulose plates, injection volume, development distance, and flow rate (in case of overpressured thin layer chromatography) were taken into consideration for the development of the chromatographic separation. Moreover, a microdigestion method employing nitric acid for the As spots containing PEI cellulose scratched from the developed plates divided into segments was developed for the subsequent total reflection X-ray fluorescence spectrometry analysis. The method was applied for analysis of root extracts of cucumber plants grown in As(III) containing modified Hoagland nutrient solution. Both As(III) and As(V) were detected by applying the proposed thin layer chromatography/overpressured thin layer chromatography-total reflection X-ray fluorescence spectrometry methods.

  18. Online analysis of protein inclusion bodies produced in E. coli by monitoring alterations in scattered and reflected light.

    Science.gov (United States)

    Ude, Christian; Ben-Dov, Nadav; Jochums, André; Li, Zhaopeng; Segal, Ester; Scheper, Thomas; Beutel, Sascha

    2016-05-01

    The online monitoring of recombinant protein aggregate inclusion bodies during microbial cultivation is an immense challenge. Measurement of scattered and reflected light offers a versatile and non-invasive measurement technique. Therefore, we investigated two methods to detect the formation of inclusion bodies and monitor their production: (1) online 180° scattered light measurement (λ = 625 nm) using a sensor platform during cultivation in shake flask and (2) online measurement of the light reflective interference using a porous Si-based optical biosensor (SiPA). It could be shown that 180° scattered light measurement allows monitoring of alterations in the optical properties of Escherichia coli BL21 cells, associated with the formation of inclusion bodies during cultivation. A reproducible linear correlation between the inclusion body concentration of the non-fluorescent protein human leukemia inhibitory factor (hLIF) carrying a thioredoxin tag and the shift ("Δamp") in scattered light signal intensity was observed. This was also observed for the glutathione-S-transferase-tagged green fluorescent protein (GFP-GST). Continuous online monitoring of reflective interference spectra reveals a significant increase in the bacterium refractive index during hLIF production in comparison to a non-induced reference that coincide with the formation of inclusion bodies. These online monitoring techniques could be applied for fast and cost-effective screening of different protein expression systems.

  19. Total reflection X-ray fluorescence analysis of river waters in its stream across the city of Cordoba, in Argentina

    International Nuclear Information System (INIS)

    Valentinuzzi, M.C.; Sanchez, H.J.; Abraham, J.

    2006-01-01

    The aim of this work was to analyze the composition of river waters and to study their quality by detecting possible contaminants. The samples were taken at 32 points of the Suquia River in its stream across the city of Cordoba (in the Province of Cordoba, Argentina). The samples were analyzed with total reflection X-ray fluorescence (TXRF) using beam guides. Beam guides made of two Si plate reflectors were used as sample carriers and to guide the X-ray photons to the sample; the measurements were taken using the characteristic configuration that ensures the best excitation and detection conditions (in TXRF). The analyses were carried out by preconcentration of the water samples and by adding an internal standard (Gallium); small amounts of samples (30 μl) were deposited on the Si reflector plate and they were then analyzed in the total reflection regime. Spectra were analyzed with standard methods using conventional programs. The results show interesting behaviors of the concentration of trace elements along the river: elements of low atomic number (such as Ca, Cl, S, K) present higher concentrations as compared to high Z elements (such as Fe, Zn, Br, Sr); the concentrations of light elements follow a similar behavior along the stream, the same situation is observed in the set of elements with high atomic number. Some samples present high concentrations in certain elements indicating possible sources of contamination

  20. An optimised set-up for total reflection particle induced X-ray emission

    International Nuclear Information System (INIS)

    Kan, J.A. van; Vis, R.D.

    1997-01-01

    MeV proton beams at small angles of incidence (0-35 mrad) are used to analyse trace elements on flat surfaces such as Si wafers or quartz substrates. In these experiments, the particle induced X-ray emission (PIXE) signal is used in a new optimized set-up. This set-up is constructed in such a way that the X-ray detector can reach very large solid angles, larger than 1 sr. Use of these large detector solid angles, combined with the reduction of bremsstrahlung background, affords limits of detection (LOD) of the order of 10 10 at cm -2 using total reflection particle induced X-ray emission (TPIXE). The LODs from earlier TPIXE measurements in a non-optimized set-up are used to estimate LODs in the new TPIXE set-up. Si wafers with low surface concentrations of V, Ni, Cu and Ag are used as standards to calibrate the LODs found with this set-up. The metal concentrations are determined by total reflection X-ray fluorescence (TXRF). The TPIXE measurements are compared with TXRF measurements on the same wafers. (Author)

  1. Smooth and rough Proteus mirabilis lipopolysaccharides studied by total internal reflection ellipsometry

    International Nuclear Information System (INIS)

    Gleńska-Olender, J.; Dworecki, K.; Sęk, S.; Kwinkowski, M.; Kaca, W.

    2013-01-01

    Total internal reflection ellipsometry (TIRE), a label-free optical detection technique for studying interactions between biomolecules, was used to examine the adsorption of various forms of lipopolysaccharides (LPSs) isolated from Proteus mirabilis S1959, R110, and R45 strains on a gold surface. The thickness of the adsorbed layers was determined by TIRE, with the average values for S1959, R110, and R45 LPS layers being 78 ± 5, 39 ± 3, and 12 ± 2 nm, respectively. The thickness of LPS layers corresponds to the presence and length of O-specific parts in P. mirabilis LPS molecules. Atomic force microscopy was used as a complementary technique for visualizing lipopolysaccharides on the surface. Force measurements seem to confirm the data obtained from TIRE experiments. - Highlights: • Proteus mirabilis lipopolysaccharides were adsorbed on the gold surface. • Thickness of adsorbed layers was determined by total internal reflection ellipsometry. • Atomic force microscopy was used to visualize lipopolysaccharide build-up on gold surface. • Time is important in the evolution of biomolecular film thickness created on gold surface

  2. Smooth and rough Proteus mirabilis lipopolysaccharides studied by total internal reflection ellipsometry

    Energy Technology Data Exchange (ETDEWEB)

    Gleńska-Olender, J., E-mail: joannaglenska@wp.pl [Institute of Biology, Jan Kochanowski University, 25-406 Kielce (Poland); Świętokrzyski Biobank, Regional Science and Technology Center, 26-060 Chęciny (Poland); Dworecki, K. [Institute of Physics, Jan Kochanowski University, 25-406 Kielce (Poland); Sęk, S. [Department of Chemistry, University of Warsaw, 02-093 Warsaw (Poland); Kwinkowski, M.; Kaca, W. [Institute of Biology, Jan Kochanowski University, 25-406 Kielce (Poland)

    2013-12-02

    Total internal reflection ellipsometry (TIRE), a label-free optical detection technique for studying interactions between biomolecules, was used to examine the adsorption of various forms of lipopolysaccharides (LPSs) isolated from Proteus mirabilis S1959, R110, and R45 strains on a gold surface. The thickness of the adsorbed layers was determined by TIRE, with the average values for S1959, R110, and R45 LPS layers being 78 ± 5, 39 ± 3, and 12 ± 2 nm, respectively. The thickness of LPS layers corresponds to the presence and length of O-specific parts in P. mirabilis LPS molecules. Atomic force microscopy was used as a complementary technique for visualizing lipopolysaccharides on the surface. Force measurements seem to confirm the data obtained from TIRE experiments. - Highlights: • Proteus mirabilis lipopolysaccharides were adsorbed on the gold surface. • Thickness of adsorbed layers was determined by total internal reflection ellipsometry. • Atomic force microscopy was used to visualize lipopolysaccharide build-up on gold surface. • Time is important in the evolution of biomolecular film thickness created on gold surface.

  3. Microplate-compatible total internal reflection fluorescence microscopy for receptor pharmacology

    Science.gov (United States)

    Chen, Minghan; Zaytseva, Natalya V.; Wu, Qi; Li, Min; Fang, Ye

    2013-05-01

    We report the use of total internal reflection fluorescence (TIRF) microscopy for analyzing receptor pharmacology and the development of a microplate-compatible TIRF imaging system. Using stably expressed green fluorescence protein tagged β2-adrenergic receptor as the reporter, we found that the activation of different receptors results in distinct kinetic signatures of the TIRF intensity of cells. These TIRF signatures closely resemble the characteristics of their respective label-free dynamic mass redistribution signals in the same cells. This suggests that TIRF in microplate can be used for profiling and screening drugs.

  4. Catheter based mid-infrared reflectance and reflectance generated absorption spectroscopy

    Science.gov (United States)

    Holman, Hoi-Ying N

    2013-10-29

    A method of characterizing conditions in a tissue, by (a) providing a catheter that has a light source that emits light in selected wavenumbers within the range of mid-IR spectrum; (b) directing the light from the catheter to an area of tissue at a location inside a blood vessel of a subject; (c) collecting light reflected from the location and generating a reflectance spectra; and (d) comparing the reflectance spectra to a reference spectra of normal tissue, whereby a location having an increased number of absorbance peaks at said selected wavenumbers indicates a tissue inside the blood vessel containing a physiological marker for atherosclerosis.

  5. Degrees of polarization of reflected light eliciting polarotaxis in dragonflies (Odonata), mayflies (Ephemeroptera) and tabanid flies (Tabanidae).

    Science.gov (United States)

    Kriska, György; Bernáth, Balázs; Farkas, Róbert; Horváth, Gábor

    2009-12-01

    With few exceptions insects whose larvae develop in freshwater possess positive polarotaxis, i.e., are attracted to sources of horizontally polarized light, because they detect water by means of the horizontal polarization of light reflected from the water surface. These insects can be deceived by artificial surfaces (e.g. oil lakes, asphalt roads, black plastic sheets, dark-coloured cars, black gravestones, dark glass surfaces, solar panels) reflecting highly and horizontally polarized light. Apart from the surface characteristics, the extent of such a 'polarized light pollution' depends on the illumination conditions, direction of view, and the threshold p* of polarization sensitivity of a given aquatic insect species. p* means the minimum degree of linear polarization p of reflected light that can elicit positive polarotaxis from a given insect species. Earlier there were no quantitative data on p* in aquatic insects. The aim of this work is to provide such data. Using imaging polarimetry in the red, green and blue parts of the spectrum, in multiple-choice field experiments we measured the threshold p* of ventral polarization sensitivity in mayflies, dragonflies and tabanid flies, the positive polarotaxis of which has been shown earlier. In the blue (450nm) spectral range, for example, we obtained the following thresholds: dragonflies: Enallagma cyathigerum (0%

  6. Applications of total reflection X-ray fluorescence in multi-element analysis

    International Nuclear Information System (INIS)

    Michaelis, W.; Prange, A.; Knoth, J.

    1985-01-01

    Although Total Reflection X-Ray Fluorescence Analysis (TXRF) became available for practical applications and routine measurements only few years ago, the number of programmes that make use of this method is increasing rapidly. The scope of work is widespread over environmental research and monitoring, mineralogy, mineral exploration, oceanography, biology, medicine and biochemistry. The present paper gives a brief survey of these applications and summarizes some of them which are typical for quite different matrices. (orig.)

  7. Measurement of refractive indices of tunicates' tunics: light reflection of the transparent integuments in an ascidian Rhopalaea sp. and a salp Thetys vagina.

    Science.gov (United States)

    Kakiuchida, Hiroshi; Sakai, Daisuke; Nishikawa, Jun; Hirose, Euichi

    2017-01-01

    Tunic is a cellulosic, integumentary matrix found in tunicates (Subphylum Tunicata or Urochordata). The tunics of some ascidian species and pelagic tunicates, such as salps, are nearly transparent, which is useful in predator avoidance. Transparent materials can be detected visually using light reflected from their surfaces, with the different refractive indices between two media, i.e., tunic and seawater, being the measure of reflectance. A larger difference in refractive indices thus provides a larger measure of reflectance. We measured the refractive indices of the transparent tunic of Thetys vagina (salp: Thaliacea) and Rhopalae a sp. (ascidian: Ascidiacea) using an Abbe refractometer and an ellipsometer to estimate the light reflection at the tunic surface and evaluate the anti-reflection effect of the nipple array structure on the tunic surface of T. vagina . At D-line light (λ = 589 nm), the refractive indices of the tunics were 0.002-0.004 greater than seawater in the measurements by Abbe refractometer, and 0.02-0.03 greater than seawater in the measurements by ellipsometer. The refractive indices of tunics were slightly higher than that of seawater. According to the simulation of light reflection based on rigorous coupled wave analysis (RCWA), light at a large angle of incidence will be completely reflected from a surface when its refractive indices are smaller than seawater. Therefore, the refractive index of integument is important for enabling transparent organisms to remain invisible in the water column. In order to minimize reflectance, the refractive index should be similar to, but never smaller than, that of the surrounding seawater. The simulation also indicated that the presence or absence of a nipple array does not cause significant difference in reflectance on the surface. The nipple array on the tunic of the diurnal salp may have another function, such as bubble repellence, other than anti-reflection.

  8. The Photosensitivity of Rhodopsin Bleaching and Light-Induced Increases of Fundus Reflectance in Mice Measured In Vivo With Scanning Laser Ophthalmoscopy

    Science.gov (United States)

    Zhang, Pengfei; Goswami, Mayank; Zawadzki, Robert J.; Pugh, Edward N.

    2016-01-01

    Purpose To quantify bleaching-induced changes in fundus reflectance in the mouse retina. Methods Light reflected from the fundus of albino (Balb/c) and pigmented (C57Bl/6J) mice was measured with a multichannel scanning laser ophthalmoscopy optical coherence tomography (SLO-OCT) optical system. Serial scanning of small retinal regions was used for bleaching rhodopsin and measuring reflectance changes. Results Serial scanning generated a saturating reflectance increase centered at 501 nm with a photosensitivity of 1.4 × 10−8 per molecule μm2 in both strains, 2-fold higher than expected were irradiance at the rod outer segment base equal to that at the retinal surface. The action spectrum of the reflectance increase corresponds to the absorption spectrum of mouse rhodopsin in situ. Spectra obtained before and after bleaching were fitted with a model of fundus reflectance, quantifying contributions from loss of rhodopsin absorption with bleaching, absorption by oxygenated hemoglobin (HbO2) in the choroid (Balb/c), and absorption by melanin (C57Bl/6J). Both mouse strains exhibited light-induced broadband reflectance changes explained as bleaching-induced reflectivity increases at photoreceptor inner segment/outer segment (IS/OS) junctions and OS tips. Conclusions The elevated photosensitivity of rhodopsin bleaching in vivo is explained by waveguide condensing of light in propagation from rod inner segment (RIS) to rod outer segment (ROS). The similar photosensitivity of rhodopsin in the two strains reveals that little light backscattered from the sclera can enter the ROS. The bleaching-induced increases in reflectance at the IS/OS junctions and OS tips resemble results previously reported in human cones, but are ascribed to rods due to their 30/1 predominance over cones in mice and to the relatively minor amount of cone M-opsin in the regions scanned. PMID:27403994

  9. Food for thought: Conditions for discourse reflection in the light of environmental assessment

    International Nuclear Information System (INIS)

    Runhaar, Hens; Runhaar, Piety R.; Oegema, Tammo

    2010-01-01

    People tend to take notice of what is happening around them selectively. Discourses-frames through which actors give meaning to aspects of the world-act as built-in filters that distinguish relevant from irrelevant data. Use of knowledge generated by environmental assessments (EAs) in decision-making may be understood from this perspective. Environmental knowledge that is inconsistent with dominant discourses runs the risk of being ignored. Discourses on the value of EA as a tool for decision-making may have a similar effect. Stimulating decision-makers and stakeholders to critically reflect on and reconsider their discourses in the light of EAs-also known as frame reflection or policy learning-may enhance the probability that these assessments and the knowledge that they generate impact upon decision-making. Up to now little has been written about how discourse reflection in the context of EA can be promoted. Valuable inputs are fragmented over different bodies of literature. In this paper we draw from these bodies to identify favourable conditions for discourse reflection.

  10. Recent results of synchrotron radiation induced total reflection X-ray fluorescence analysis at HASYLAB, beamline L

    Energy Technology Data Exchange (ETDEWEB)

    Streli, C. [Atominstitut, Vienna University of Technology, Stadionallee 2, A-1020 Vienna (Austria)]. E-mail: streli@ati.ac.at; Pepponi, G. [ITC-irst, Povo (Italy); Wobrauschek, P. [Atominstitut, Vienna University of Technology, Stadionallee 2, A-1020 Vienna (Austria); Jokubonis, C. [Atominstitut, Vienna University of Technology, Stadionallee 2, A-1020 Vienna (Austria); Falkenberg, G. [Hamburger Synchrotronstrahlungslabor at Deutsches Elektronen-Synchrotron DESY, Notkestr. 85, D-22603 Hamburg (Germany); Zaray, G. [Institute of Inorganic and Applied Chemistry, 3 EOTVOS Univ, Budapest (Hungary); Broekaert, J. [Institute of Anorganic and Applied Chemistry, University Hamburg, Martin-Luther-King-Platz 6, 20146 Hamburg (Germany); Fittschen, U. [Institute of Anorganic and Applied Chemistry, University Hamburg, Martin-Luther-King-Platz 6, 20146 Hamburg (Germany); Peschel, B. [Institute of Anorganic and Applied Chemistry, University Hamburg, Martin-Luther-King-Platz 6, 20146 Hamburg (Germany)

    2006-11-15

    At the Hamburger Synchrotronstrahlungslabor (HASYLAB), Beamline L, a vacuum chamber for synchrotron radiation-induced total reflection X-ray fluorescence analysis, is now available which can easily be installed using the adjustment components for microanalysis present at this beamline. The detector is now in the final version of a Vortex silicon drift detector with 50-mm{sup 2} active area from Radiant Detector Technologies. With the Ni/C multilayer monochromator set to 17 keV extrapolated detection limits of 8 fg were obtained using the 50-mm{sup 2} silicon drift detector with 1000 s live time on a sample containing 100 pg of Ni. Various applications are presented, especially of samples which are available in very small amounts: As synchrotron radiation-induced total reflection X-ray fluorescence analysis is much more sensitive than tube-excited total reflection X-ray fluorescence analysis, the sampling time of aerosol samples can be diminished, resulting in a more precise time resolution of atmospheric events. Aerosols, directly sampled on Si reflectors in an impactor were investigated. A further application was the determination of contamination elements in a slurry of high-purity Al{sub 2}O{sub 3}. No digestion is required; the sample is pipetted and dried before analysis. A comparison with laboratory total reflection X-ray fluorescence analysis showed the higher sensitivity of synchrotron radiation-induced total reflection X-ray fluorescence analysis, more contamination elements could be detected. Using the Si-111 crystal monochromator also available at beamline L, XANES measurements to determine the chemical state were performed. This is only possible with lower sensitivity as the flux transmitted by the crystal monochromator is about a factor of 100 lower than that transmitted by the multilayer monochromator. Preliminary results of X-ray absorption near-edge structure measurements for As in xylem sap from cucumber plants fed with As(III) and As(V) are

  11. Recent results of synchrotron radiation induced total reflection X-ray fluorescence analysis at HASYLAB, beamline L

    International Nuclear Information System (INIS)

    Streli, C.; Pepponi, G.; Wobrauschek, P.; Jokubonis, C.; Falkenberg, G.; Zaray, G.; Broekaert, J.; Fittschen, U.; Peschel, B.

    2006-01-01

    At the Hamburger Synchrotronstrahlungslabor (HASYLAB), Beamline L, a vacuum chamber for synchrotron radiation-induced total reflection X-ray fluorescence analysis, is now available which can easily be installed using the adjustment components for microanalysis present at this beamline. The detector is now in the final version of a Vortex silicon drift detector with 50-mm 2 active area from Radiant Detector Technologies. With the Ni/C multilayer monochromator set to 17 keV extrapolated detection limits of 8 fg were obtained using the 50-mm 2 silicon drift detector with 1000 s live time on a sample containing 100 pg of Ni. Various applications are presented, especially of samples which are available in very small amounts: As synchrotron radiation-induced total reflection X-ray fluorescence analysis is much more sensitive than tube-excited total reflection X-ray fluorescence analysis, the sampling time of aerosol samples can be diminished, resulting in a more precise time resolution of atmospheric events. Aerosols, directly sampled on Si reflectors in an impactor were investigated. A further application was the determination of contamination elements in a slurry of high-purity Al 2 O 3 . No digestion is required; the sample is pipetted and dried before analysis. A comparison with laboratory total reflection X-ray fluorescence analysis showed the higher sensitivity of synchrotron radiation-induced total reflection X-ray fluorescence analysis, more contamination elements could be detected. Using the Si-111 crystal monochromator also available at beamline L, XANES measurements to determine the chemical state were performed. This is only possible with lower sensitivity as the flux transmitted by the crystal monochromator is about a factor of 100 lower than that transmitted by the multilayer monochromator. Preliminary results of X-ray absorption near-edge structure measurements for As in xylem sap from cucumber plants fed with As(III) and As(V) are reported. Detection

  12. Total Internal Reflection Fluorescence Microscopy Imaging-Guided Confocal Single-Molecule Fluorescence Spectroscopy

    OpenAIRE

    Zheng, Desheng; Kaldaras, Leonora; Lu, H. Peter

    2013-01-01

    We have developed an integrated spectroscopy system combining total internal reflection fluorescence microscopy imaging with confocal single-molecule fluorescence spectroscopy for two-dimensional interfaces. This spectroscopy approach is capable of both multiple molecules simultaneously sampling and in situ confocal fluorescence dynamics analyses of individual molecules of interest. We have demonstrated the calibration with fluorescent microspheres, and carried out single-molecule spectroscop...

  13. Multielemental analysis in cigarettes using total reflection X-ray fluorescence with synchrotron radiation

    International Nuclear Information System (INIS)

    Barbosa, R.F.; Anjos, M.J. dos; Jesus, E.F.O. de; Lopes, R.T.; Moreira, S.

    2008-01-01

    Full text: It is well known that trace elements have important ejects in the life processes. Some of these elements are toxic for the human even at a very low level of intake. It is known that tobacco plant easily absorbs the heavy metals from the soil, especially Cd and Ni, accumulating them in its leaves. Part of these metals are transferred from tobacco to human body where they will be accumulated and damage some organs, mainly kidneys and liver. In this way, cigarettes are responsible for the death of millions of people in the world, about one death every eight seconds. The aim of this work was to determine the elemental concentrations of ten different elements in tobacco of Brazilian cigarettes used Total Reflection X-Ray Fluorescence with Synchrotron Radiation method. The fluorescence measurements were carried out at Brazilian Synchrotron Light Laboratory, Campinas - Sao Paulo. A qualitative analysis of spectral peaks showed that the samples contained potassium, calcium, titanium, chromium, manganese, iron, copper, rubidium and strontium. Among these elements, calcium, potassium and iron presented the highest concentrations. There was a wide range in the elemental concentrations in the tobacco, due various factors, such as agricultural practices, soil characteristics, climatic conditions and plant varieties. Our results are in good concern with the results reported by the scientific literature

  14. Dose determination with nitro blue tetrazolium containing radiochromic dye films by measuring absorbed and reflected light

    DEFF Research Database (Denmark)

    Kovács, A.; Baranyai, M.; Wojnárovits, L.

    2000-01-01

    determination in a wide dose range both by absorbance and reflectance measurements. The concept of measuring reflected light from dose labels has been discussed earlier and emerged recently due to the requirement of introducing semiquantitative label dose indicators for quarantine control. The usefulness...... of the method was studied using the newly developed radiochromic dye films as well as already existing ones. (C) 2000 Elsevier Science Ltd. All rights reserved....

  15. Application of the Total Reflection X-ray Fluorescence technique to trace elements determination in tobacco

    International Nuclear Information System (INIS)

    Martinez, T.; Lartigue, J.; Zarazua, G.; Avila-Perez, P.; Navarrete, M.; Tejeda, S.

    2008-01-01

    Many studies have identified an important number of toxic elements along with organic carcinogen molecules and radioactive isotopes in tobacco. In this work we have analyzed by Total Reflection X-Ray Fluorescence 9 brands of cigarettes being manufactured and distributed in the Mexican market. Two National Institute of Standards and Technology standards and a blank were equally treated at the same time. Results show the presence of some toxic elements such as Pb and Ni. These results are compared with available data for some foreign brands, while their implications for health are discussed. It can be confirmed that the Total Reflection X-Ray Fluorescence method provides precise (reproducible) and accuracy (trueness) data for 15 elements concentration in tobacco samples

  16. Application of the Total Reflection X-ray Fluorescence technique to trace elements determination in tobacco

    Science.gov (United States)

    Martinez, T.; Lartigue, J.; Zarazua, G.; Avila-Perez, P.; Navarrete, M.; Tejeda, S.

    2008-12-01

    Many studies have identified an important number of toxic elements along with organic carcinogen molecules and radioactive isotopes in tobacco. In this work we have analyzed by Total Reflection X-Ray Fluorescence 9 brands of cigarettes being manufactured and distributed in the Mexican market. Two National Institute of Standards and Technology standards and a blank were equally treated at the same time. Results show the presence of some toxic elements such as Pb and Ni. These results are compared with available data for some foreign brands, while their implications for health are discussed. It can be confirmed that the Total Reflection X-Ray Fluorescence method provides precise (reproducible) and accuracy (trueness) data for 15 elements concentration in tobacco samples.

  17. CR-39 (PADC) Reflection and Transmission of Light in the Ultraviolet-Near-Infrared (UV-NIR) Range.

    Science.gov (United States)

    Traynor, Nathan B J; McLauchlin, Christopher; Dodge, Kenneth; McGarrah, James E; Padalino, Stephen J; McCluskey, Michelle; Sangster, T C; McLean, James G

    2018-04-01

    The spectral reflection (specular and diffuse) and transmission of Columbia Resin 39 (CR-39) were measured for incoherent light with wavelengths in the range of 200-2500 nm. These results will be of use for the optical characterization of CR-39, as well as in investigations of the chemical modifications of the polymer caused by ultraviolet (UV) exposure. A Varian Cary 5000 was used to perform spectroscopy on several different thicknesses of CR-39. With proper analysis for the interdependence of reflectance and transmittance, results are consistent across all samples. The reflectivity from each CR-39-air boundary reveals an increase in the index of refraction in the near-UV. Absorption observations are consistent with the Beer-Lambert law. Strong absorption of UV light of wavelength shorter than 350 nm suggests an optical band gap of 3.5 eV, although the standard analysis is not conclusive. Absorption features observed in the near infrared are assigned to molecular vibrations, including some that are new to the literature.

  18. An Entertaining Method of Teaching Concepts of Linear Light Propagation, Reflection and Refraction Using a Simple Optical Mechanism

    Science.gov (United States)

    Yurumezoglu, K.

    2009-01-01

    An activity has been designed for the purpose of teaching how light is dispersed in a straight line and about the interaction between matter and light as well as the related concepts of shadows, partial shadows, reflection, refraction, primary colours and complementary (secondary) colours, and differentiating the relationship between colours, all…

  19. Reflection of circularly polarized light and the effect of particle distribution on circular dichroism in evaporation induced self-assembled cellulose nanocrystal thin films

    Directory of Open Access Journals (Sweden)

    D. Hewson

    2017-06-01

    Full Text Available Evaporation induced self-assembled (EISA thin films of cellulose nanocrystals (CNCs have shown great potential for displaying structural colour across the visible spectrum. They are believed primarily to reflect left handed circularly polarised (LCP light due to their natural tendency to form structures comprising left handed chirality. Accordingly the fabrication of homogenously coloured CNC thin films is challenging. Deposition of solid material towards the edge of a dried droplet, via the coffee-stain effect, is one such difficulty in achieving homogenous colour across CNC films. These effects are most easily observed in films prepared from droplets where observable reflection of visible light is localised around the edge of the dry film. We report here, the observation of both left and right hand circularly polarised (LCP/RCP light in reflection from distinct separate regions of CNC EISA thin films and we elucidate how these reflections are dependent on the distribution of CNC material within the EISA thin film. Optical models of reflection are presented which are based on structures revealed using high resolution transmission electron microscopy (TEM images of film cross sections. We have also employed spectroscopic characterisation techniques to evaluate the distribution of solid CNC material within a selection of CNC EISA thin films and we have correlated this distribution with polarised light spectra collected from each film. We conclude that film regions from which RCP light was reflected were associated with lower CNC concentrations and thicker film regions.

  20. Effects of bonny light crude oil on anti-oxidative enzymes and total ...

    African Journals Online (AJOL)

    Effects of bonny light crude oil on anti-oxidative enzymes and total proteins in Wistar rats. Christian E Odo, Okwesili FC Nwodo, Parker E Joshua, Chibuike S Ubani, Okon E Etim, Okechukwu PC Ugwu ...

  1. Suppression of Melatonin Secretion in Totally Visually Blind People by Ocular Exposure to White Light: Clinical Characteristics.

    Science.gov (United States)

    Hull, Joseph T; Czeisler, Charles A; Lockley, Steven W

    2018-04-03

    Although most totally visually blind individuals exhibit nonentrained circadian rhythms due to an inability of light to entrain the circadian pacemaker, a small proportion retain photic circadian entrainment, melatonin suppression, and other nonimage-forming responses to light. It is thought that these responses to light persist because of the survival of melanospin-containing intrinsically photosensitive retinal ganglion cells (ipRGCs), which project primarily to the circadian pacemaker and are functionally distinct from the rod and cone photoreceptors that mediate vision. We aimed to assess the integrity of nonimage-forming photoreception in totally visually blind patients with a range of ocular disorders. Within-subject, dark-controlled design. A total of 18 totally visually blind individuals (7 females; mean age ± standard deviation = 49.8±11.0 years) with various causes of blindness, including 3 bilaterally enucleated controls. Melatonin concentrations were compared during exposure to a 6.5-hour bright white light (∼7000 lux) with melatonin concentrations measured 24 hours earlier at the corresponding clock times under dim-light (4 lux) conditions. Area under the curve (AUC) for melatonin concentration. Melatonin concentrations were significantly suppressed (defined as ≥33% suppression) during the bright-light condition compared with the dim-light condition in 5 of 15 participants with eyes (retinitis pigmentosa, n = 2; retinopathy of prematurity [ROP], n = 2; bilateral retinal detachments, n = 1). Melatonin concentrations remained unchanged in response to light in the remaining 10 participants with eyes (ROP, n = 3; optic neuritis/neuropathy, n = 2; retinopathy unknown, n = 2; congenital glaucoma, n = 1; congenital rubella syndrome, n = 1; measles retinopathy, n = 1) and in all 3 bilaterally enucleated participants. These data confirm that light-induced suppression of melatonin remains functionally intact in a minority of totally visually

  2. CO Adsorption and Oxidation at the Catalyst-Water Interface: An Investigation by Attenuated Total Reflection Infrared Spectroscopy.

    NARCIS (Netherlands)

    Ebbesen, S.D.; Mojet, Barbara; Lefferts, Leonardus

    2006-01-01

    Adsorption of carbon monoxide and oxidation of preadsorbed carbon monoxide from gas and aqueous phases were studied on a platinum catalyst deposited on a ZnSe internal reflection element (IRE) using attenuated total reflection infrared (ATR-IR) spectroscopy. The results of this study convincingly

  3. Observation of two regions of selective light reflection from a thin film of a cholesteric liquid crystal

    International Nuclear Information System (INIS)

    Alaverdyan, R B; Dadalyan, T K; Chilingaryan, Yurii S

    2013-01-01

    Two regions of selective light reflection (in the short- and long- wavelength parts of the visible spectrum) from a thin film of a cholesteric liquid crystal (CLC), consisting of the mixture of two CLCs with opposite chirality and a nematic liquid crystal, are experimentally found for the first time. The spectral position of the reflection regions and the separation between them varies depending on the CLC composition and the temperature. The long-wavelength region of reflection corresponds to the region of Bragg reflection from the CLC helix, while the short-wavelength region is probably due to the defects in the structure of the CLC film. (letters)

  4. Metallic attenuated total reflection infrared hollow fibers for robust optical transmission systems

    Energy Technology Data Exchange (ETDEWEB)

    Jing, Chengbin; Guo, Hong; Hu, Zhigao; Yang, Pingxiong [Key Laboratory of Polar Materials and Devices, Ministry of Education, Department of Electronic Engineering, East China Normal University, 500 Dongchuan Road, Shanghai 200241 (China); Chu, Junhao [Key Laboratory of Polar Materials and Devices, Ministry of Education, Department of Electronic Engineering, East China Normal University, 500 Dongchuan Road, Shanghai 200241 (China); National Laboratory for Infrared Physics, Shanghai Institute of Technical Physics, Chinese Academy of Sciences, 500 Yu-tian Road, Shanghai 200083 (China); Liu, Aiyun [Department of Physics, Shanghai Normal University, 100 Gui Lin Road, Shanghai 200234 (China); Shi, Yiwei [School of Information Science and Engineering, Fudan University, 220 Handan Road, Shanghai 200433 (China)

    2014-07-07

    A durable metallic attenuated total reflection (ATR) hollow fiber (bore size: 1.45 mm, wall thickness: 50 μm) was designed and fabricated based on a nickel capillary tube and hexagonal germanium dioxide (GeO{sub 2}). The anomalous dispersion of the hexagonal GeO{sub 2} layer grown inside a nickel tube achieves low-loss light transmission at two peak-power wavelengths for CO{sub 2} laser devices (10.2 and 10.6 μm). An 11–28 W, 10.2 or 10.6 μm CO{sub 2} laser power was steadily delivered via a fiber elastically bent from 0° to 90° (radius: 45 cm) for over 40 min (transmission loss: 0.22 to 4.2 dB/m). Theoretically fitting the measured temperatures showed that front-end clipping caused greater thermal loading than the distributed mode absorption. The maximum external temperature of a nickel ATR fiber is much lower than that of a silica glass ATR fiber owing to their different heat dissipation abilities. The HE{sub 11} mode purity of the output beam profiles decreased from 90.3% to 44.7% as the bending angle increased from 0° to 90°. Large core sizes and wall roughnesses (scattering loss 0.04 dB/m) contributed to mode mixing and excess losses that were above the value predicted by the classical Marcatili and Schmeltzer equation (0.024–0.037 dB/m).

  5. Surface characterization of selected polymer thin films by total-reflection x-ray fluorescence spectroscopy and x-ray reflectivity

    International Nuclear Information System (INIS)

    Innis, Vallerie Ann A.

    2006-01-01

    Development of available x-ray characterizations tools for grazing incidence techniques was done to be able to probe nano-size thin films. Alignment of a Philips x-ray powder diffractometer was improved to let it perform as an x-ray reflectometer. X-ray reflectometry was coupled with total-reflection x-ray fluorescence spectroscopy. Evaluation of the performance of this grazing incidence techniques was done by preparing polymer thin films of carboxymethylcellulose, carrageenan and polyvinylpyrrolidone (PVP). The thickness of the films were varied by varying the process parameters such as concentration, spin speed and spin time. Angle-dispersive total-reflection x-ray fluorescence spectroscopy profiles of three films showed film formation only in carrageenan and PVP. For both carrageenan and PVP, an increase in concentration yielded a corresponding increase in intensity of the fluorescent or scattered peaks. XRR profiles of carrageenan thin films yielded a mean value for the critical angle close to quartz substrate. Thickness measurements of the prepared carrageenan thin films showed that concentration was the main determinant for final film thickness over the other process parameters. Sulfur fluorescent intensity derived from the TXRF measurement showed a linear relationship with the measured thickness by XRR. For PVP, measured critical angle is lower than quartz. Poor adhesion of the polymer onto the substrate yielded a limited number of thickness measurements made from the XRR profiles. (Author)

  6. Gestational related changes in the deep venous system of the lower limb on light reflection rheography in pregnancy and the puerperium

    Energy Technology Data Exchange (ETDEWEB)

    Calderwood, C.J. [St John' s Hospital, Livingston and Simpson Centre for Reproductive Health, Royal Infirmary of Edinburgh, Edinburgh (United Kingdom)], E-mail: catherine.calderwood@luht.scot.nhs.uk; Jamieson, R. [Princess Royal Maternity Unit, Glasgow Royal Infirmary, Glasgow (United Kingdom); Greer, I.A. [Hull York Medical School, University of York, York (United Kingdom)

    2007-12-15

    Objective: To assess whether light reflection rheography testing is affected by the changes that occur in the deep venous system of the lower limb in pregnancy and the puerperium. Methods: Twenty five women with a singleton pregnancy were recruited to undergo duplex Doppler ultrasound examinations of the common femoral vein to measure the vessel diameter and the blood flow velocity. Light reflection rheography testing was subsequently performed and the rate of venous emptying in the lower limb calculated. Serial measurements using both techniques were made at 15, 28, 36 weeks, and term gestation and at 2 days and 6 weeks postpartum. Results: Duplex Doppler ultrasound confirmed that there is progressive dilatation of the deep venous system in pregnancy, which reaches a maximum at term and reverses after delivery. There is an accompanying reduction in blood flow velocity, which reaches a nadir at term and increases after delivery. The rate of venous emptying as measured by light reflection rheography decreases with increasing gestation, but did not fall to a level consistent with venous occlusion by a deep venous thrombosis. Conclusions: Light reflection rheography has been shown to provide reliable results in pregnancy and the puerperium. Therefore, it is a potential tool for screening for deep venous thrombosis in this population.

  7. Gestational related changes in the deep venous system of the lower limb on light reflection rheography in pregnancy and the puerperium

    International Nuclear Information System (INIS)

    Calderwood, C.J.; Jamieson, R.; Greer, I.A.

    2007-01-01

    Objective: To assess whether light reflection rheography testing is affected by the changes that occur in the deep venous system of the lower limb in pregnancy and the puerperium. Methods: Twenty five women with a singleton pregnancy were recruited to undergo duplex Doppler ultrasound examinations of the common femoral vein to measure the vessel diameter and the blood flow velocity. Light reflection rheography testing was subsequently performed and the rate of venous emptying in the lower limb calculated. Serial measurements using both techniques were made at 15, 28, 36 weeks, and term gestation and at 2 days and 6 weeks postpartum. Results: Duplex Doppler ultrasound confirmed that there is progressive dilatation of the deep venous system in pregnancy, which reaches a maximum at term and reverses after delivery. There is an accompanying reduction in blood flow velocity, which reaches a nadir at term and increases after delivery. The rate of venous emptying as measured by light reflection rheography decreases with increasing gestation, but did not fall to a level consistent with venous occlusion by a deep venous thrombosis. Conclusions: Light reflection rheography has been shown to provide reliable results in pregnancy and the puerperium. Therefore, it is a potential tool for screening for deep venous thrombosis in this population

  8. Lightness functions

    DEFF Research Database (Denmark)

    Campi, Stefano; Gardner, Richard; Gronchi, Paolo

    2012-01-01

    Variants of the brightness function of a convex body K in n-dimensional Euclidean are investigated. The Lambertian lightness function L(K; v , w ) gives the total reflected light resulting from illumination by a light source at infinity in the direction w that is visible when looking...... in the direction v . The partial brightness function R( K ; v , w ) gives the area of the projection orthogonal to v of the portion of the surface of K that is both illuminated by a light source from the direction w and visible when looking in the direction v . A class of functions called lightness functions...... is introduced that includes L(K;.) and R(K;.) as special cases. Much of the theory of the brightness function like uniqueness, stability, and the existence and properties of convex bodies of maximal and minimal volume with finitely many function values equal to those of a given convex body, is extended...

  9. Photoluminescence and reflectivity studies of high energy light ions irradiated polymethyl methacrylate films

    Science.gov (United States)

    Bharti, Madhu Lata; Singh, Fouran; Ramola, R. C.; Joshi, Veena

    2017-11-01

    The self-standing films of non-conducting polymethyl methacrylate (PMMA) were irradiated in vacuum using high energy light ions (HELIs) of 50 MeV Lithium (Li+3) and 80 MeV Carbon (C+5) at various ion dose to induce the optical changes in the films. Upon HELI irradiation, films exhibit a significant enhancement in optical reflectivity at the highest dose. Interestingly, the photoluminescence (PL) emission band with green light at (514.5 nm) shows a noticeable increase in the intensity with increasing ion dose for both ions. However, the rate of increase in PL intensity is different for both HELI and can be correlated with the linear energy transfer by these ions in the films. Origin of PL is attributed to the formation of carbon cluster and hydrogenated amorphous carbon in the polymer films. HAC clusters act as PL active centres with optical reflectivity. Most of the harmful radiation like UV are absorbed by the material and is becoming opaque after irradiation and this PL active material are useful in fabrication of optoelectronic devices, UV-filter, back-lit components in liquid crystal display systems, micro-components for integrate optical circuits, diffractive elements, advanced materials and are also applicable to the post irradiation laser treatment by means of ion irradiation.

  10. TX 2000: total reflection and 45o energy dispersive x-ray fluorescence spectrometer

    International Nuclear Information System (INIS)

    Pasti, F.; Torboli, A.; Valdes, M.

    2000-01-01

    This equipment, developed by Ital Structures, combines two kinds of energy dispersive X-ray fluorescence techniques, the first using total reflection geometry and the second conventional 45 o geometry. The equipment is completely controlled by a PC and to reach the condition of total reflection is very easy because it is enough to load the file with the right position for the corresponding energy. In this apparatus we used an x-ray tube with an alloy anode of Mo/W with a long fine focus at 2200 W. To monochromatize the x-ray beam while choosing, for example, the Mo K alpha or W L alpha or a piece of white spectrum of 33 keV, we use a highly reflective multilayer made of Si/W with 2d = 45.5 A o . The detector used in the equipment is a lithium drifted silicon detector (Si(Li)) with an excellent energy resolution of 135 eV at 5.9 keV and 1000 cps. We developed two programs written in Windows 95, 98 and NT for a 32 bit microprocessor. The first one is called TYACQ32 and has the following functions: first, complete control of the hardware, second automatic alignment of the TX 2000 spectrometer and third acquisition of spectra. The second program is EDXRF32. This is a program to accomplish spectrum and quantitative analysis for TXRF and EDXRF 45 o degrees analysis. (author)

  11. Use of total internal reflection Raman (TIR) and attenuated total reflection infrared (ATR-IR) spectroscopy to analyze component separation in thin offset ink films after setting on coated paper surfaces.

    Science.gov (United States)

    Kivioja, Antti; Hartus, Timo; Vuorinen, Tapani; Gane, Patrick; Jääskeläinen, Anna-Stiina

    2013-06-01

    The interactive behavior of ink constituents with porous substrates during and after the offset print process has an important effect on the quality of printed products. To help elucidate the distribution of ink components between the retained ink layer and the substrate, a variety of spectroscopic and microscopic analysis techniques have been developed. This paper describes for the first time the use of total internal reflection (TIR) Raman spectroscopy to analyze the penetration behavior of separated offset ink components (linseed oil, solid color pigment) in coated papers providing chemically intrinsic information rapidly, nondestructively, and with minimal sample preparation. In addition, the already widely applied technique of attenuated total reflection infrared spectroscopy (ATR-IR) was evaluated in parallel and compared. The results of the ATR-IR Raman clearly revealed an improvement in uppermost depth resolution compared with values previously published from other nondestructive techniques, and the method is shown to be capable of providing new knowledge of the setting of thin (0.25-2 μm) offset ink films, allowing the spreading and the penetration behavior on physically different paper coating surfaces to be studied.

  12. A plastic total internal reflection-based photoluminescence device for enzymatic biosensors

    Science.gov (United States)

    Thakkar, Ishan G.

    Growing concerns for quality of water, food and beverages in developing and developed countries drive sizeable markets for mass-producible, low cost devices that can measure the concentration of contaminant chemicals in water, food, and beverages rapidly and accurately. Several fiber-optic enzymatic biosensors have been reported for these applications, but they exhibit very strong presence of scattered excitation light in the signal for sensing, requiring expensive thin-film filters, and their non-planar structure makes them challenging to mass-produce. Several other planar optical waveguide-based biosensors prove to be relatively costly and more fragile due to constituent materials and the techniques involved in their fabrication. So, a plastic total internal reflection (TIR)-based low cost, low scatter, field-portable device for enzymatic biosensors is fabricated and demonstrated. The design concept of the TIR-based photoluminescent enzymatic biosensor device is explained. An analysis of economical materials with appropriate optical and chemical properties is presented. PMMA and PDMS are found to be appropriate due to their high chemical resistance, low cost, high optical transmittance and low auto-fluorescence. The techniques and procedures used for device fabrication are discussed. The device incorporated a PMMA-based optical waveguide core and PDMS-based fluid cell with simple multi-mode fiber-optics using cost-effective fabrication techniques like molding and surface modification. Several techniques of robustly depositing photoluminescent dyes on PMMA core surface are discussed. A pH-sensitive fluorescent dye, fluoresceinamine, and an O2-sensitive phosphorescent dye, Ru(dpp) both are successfully deposited using Si-adhesive gel-based as well as HydroThane-based deposition methods. Two different types of pH-sensors using two different techniques of depositing fluoresceinamine are demonstrated. Also, the effect of concentration of fluoresceinamine-dye molecules

  13. The FTIR study of uranium oxides by the method of light pipe reflection spectroscopy

    International Nuclear Information System (INIS)

    Bao Zhu Yu; Hansen, W.N.

    1988-01-01

    Light pipe infrared reflection spectra of UO 2 , UO 3 , U 3 O 8 have been studied by using an FTIR spectrometer. The uranium oxide powders were ground to ensure fine particle size and distributed on the inner surface of a straight glass pipe with gold coating. The infrared beam from the inter-ferometer was focused into one end of the pipe at 45 0 incidence and then the transmitted beam was refocused by a pair of Cassegrainian type mirrors. The resultant spectra show the infrared characteristics of the ...-U-O-U-O-..., uranyl ion UO 2 2+ bond vibration and the active lattice vibrations predicted by group theory calculations. In comparison to the transmission spectra measured by authors or reported in literature, this 45 0 incident light pipe method as well as the previous light pipe method offer advantages of sensitivity, ease of acquisition and interpretation, and require a very small sample. It confirms the power of the light pipe method for studying powders and its special utility for the infrared studies of hazardous materials. (Author)

  14. A morphological study of the sulfurisation of digenite to covellite using reflected polarised light microscopy

    DEFF Research Database (Denmark)

    Rask Møller Frøkiær, Heidi; Warner, Terence E.

    2017-01-01

    A series of copper rods were reacted with sulfur vapour in evacuated glass ampoules at ∼445 °C. Product materials were characterised by powder X-ray diffraction and reflected polarised light microscopy. Copper sulfurised rapidly to digenite, γ-Cu2-xS, under these conditions, whereas the subsequen...... of the covellite structure. Sulfurising a coil of copper wire at ∼445 °C is an effective method for synthesising covellite.......A series of copper rods were reacted with sulfur vapour in evacuated glass ampoules at ∼445 °C. Product materials were characterised by powder X-ray diffraction and reflected polarised light microscopy. Copper sulfurised rapidly to digenite, γ-Cu2-xS, under these conditions, whereas the subsequent...... − besides being a p-type metal − is ionically conducting at 445 °C, although considerably less so than digenite. We infer that the growth of platy covellite crystals and their radial alignment in the primary CuS layer are a consequence of copper ion mobility being restricted to the basal plane...

  15. Reflectance measurements of PTFE, Kapton, and PEEK for xenon scintillation light for the LZ detector.

    Science.gov (United States)

    Arthurs, M.; Batista, E.; Haefner, J.; Lorenzon, W.; Morton, D.; Neff, A.; Okunawo, M.; Pushkin, K.; Sander, A.; Stephenson, S.; Wang, Y.; LZ Collaboration

    2017-01-01

    LZ (LUX-Zeplin) is an international collaboration that will look for dark matter candidates, WIMPs (Weakly Interacting Massive Particles), through direct detection by dual-phase time projection chamber (TPC) using liquid xenon. The LZ detector will be located nearly a mile underground at SURF, South Dakota, shielded from cosmic background radiation. Seven tons active mass of liquid xenon will be used for detecting the weak interaction of WIMPs with ordinary matter. Over three years of operation it is expected to reach the ultimate sensitivity of 2x10-48 cm2 for a WIMP mass of 50 GeV. As for many other rare event searches, high light collection efficiency is essential for LZ detector. Moreover, in order to achieve greater active volume for detection as well as reduce potential backgrounds, thinner detector walls without significant loss in reflectance are desired. Reflectance measurements of polytetrafluoroethylene (PTFE), Kapton, and PEEK for xenon scintillation light (178 nm), conducted at the University of Michigan using the Michigan Xenon Detector (MiX) will be presented. The University of Michigan, LZ Collaboration, The US Department of Energy.

  16. Attenuated total reflection design for in situ FT-IR spectroelectrochemical studies

    International Nuclear Information System (INIS)

    Visser, Hendrik; Curtright, Aimee E.; McCusker, James K.; Sauer, Kenneth

    2000-01-01

    A versatile spectroelectrochemical apparatus is introduced to study the changes in IR spectra of organic and inorganic compounds upon oxidation or reduction. The design is based on an attenuated total reflection (ATR) device, which permits the study of a wide spectral range of 16,700 cm-1 (600 nm) - 250 cm-1 with a small opaque region of 2250 - 1900 cm-1. In addition, an IR data collection protocol is introduced to deal with electrochemically non-reversible background signals. This method is tested with ferrocene in acetonitrile, producing results that agree with those in the literature

  17. Total reflection X-ray fluorescence with synchrotron radiation applied to biological and environmental samples

    International Nuclear Information System (INIS)

    Simabuco, S.M.; Matsumoto, E.; Jesus, E.F.O.; Lopes, R.T.; Perez, C.; Nascimento Filho, V.F.; Costa, R.S.S.; Tavares do Carmo, M.G.; Saunders, C.

    2001-01-01

    Full text: The Total Reflection X-ray Fluorescence has been applied for trace elements in water and aqueous solutions, environmental samples and biological materials after sample preparation and to surface analysis of silicon wafers. The present paper shows some results of applications for rainwater, atmospheric particulate material, colostrum and nuclear samples. (author)

  18. Light reflection from crystal platelets in iridophores determines green or brown skin coloration in Takydromus lizards.

    Science.gov (United States)

    Kuriyama, Takeo; Esashi, Jyunko; Hasegawa, Masami

    2017-04-01

    Brown and green are the most commonly imitated colors in prey animals because both colors occur in a range of habitats. Many researchers have evaluated survival with respect to background color matching, but the pigment cell mechanisms underlying such coloration are not known. Dorsal coloration of East Asian Takydromus lizards has shifted from green to brown or from brown to green on multiple occasions during the diversification of the genus, thus giving us an opportunity to examine the cellular mechanisms of background color matching. Brown and green skin were found to differ with respect to the morphological characteristics of iridophores, with different thicknesses of the reflecting platelets and the cytoplasmic spacing between platelets, despite a shared vertical arrangement of pigment cells, i.e., xanthophores in the upper layer, iridophores in the middle layer, and melanophores at the bottom of the dermal layer, among the different Takydromus lizards. Iridophores of brown skin reflected longer wavelengths of light than those of green skin, which may be attributed to the thicker platelets and longer distances between platelets in brown skin. We discuss the potential role of genetic and intracellular mechanisms explaining the thickness and orientation of the light-reflecting platelets of iridophores in Takydromus lizards. Copyright © 2016 Elsevier GmbH. All rights reserved.

  19. Monitoring environmental pollution of trace elements in tree-rings by synchrotron radiation total reflection X-ray fluorescence analysis (SR-TXRF)

    International Nuclear Information System (INIS)

    Moreira, Silvana; Vives, Ana Elisa S. de; Brienza, Sandra Maria B.; Medeiros, Jean Gabriel S.; Tomazello Filho, Mario; Zucchi, Orgheda L.A.D.; Nascimento Filho, Virgilio F.

    2005-01-01

    This paper aims to study the environmental pollution in the tree development, as a manner to evaluate its use as bioindicator in urban and country sides. The sample collecting was carry out in Piracicaba city, Sao Paulo State, that presents high level of environmental contamination of the water, soil and air, due industrial activities, vehicles combustion, sugar-cane leaves burning in the harvesting, etc. It was selected the Caesalpinia peltophoroides ('Sibipiruna') specie because its very used in urban arborization. It was employed the analytical technique named total reflection X-ray fluorescence (TXRF) to identify and quantify the elements and metals of nutritional and toxicological importance in the wood samples. The analysis was done in the Brazilian Synchrotron Light Laboratory, using a white beam for excitation and a Si(Li) detector for characteristic X-ray detection. It was quantified the P, K, Ca, Ti, Fe, Sr, Ba e Pb elements. (author)

  20. Trajectory method in the theory of Laue diffraction of X rays in crystals: II. Effect of total reflection at bending deformation

    International Nuclear Information System (INIS)

    Kohn, V. G.

    2008-01-01

    The effect of total reflection (switching) of a spherical X-ray wave in the case of Laue diffraction in a crystal with bending deformation is analyzed by the trajectory method. Qualitative analytical description and computation of the spatial structure of the reflected beam for large and small distances between the spherical-wave source and the crystal are performed. The mechanism of much more efficient reflection of an X-ray beam by a deformed crystal in comparison with a perfect crystal is clearly demonstrated. It is also shown that the trajectory method is very convenient for description of the total reflection phenomenon.

  1. Trajectory method in the theory of Laue diffraction of X rays in crystals: II. Effect of total reflection at bending deformation

    International Nuclear Information System (INIS)

    Kohn, V. G.

    2008-01-01

    The effect of total reflection (switching) of a spherical X-ray wave in the case of Laue diffraction in a crystal with bending deformation is analyzed by the trajectory method. Qualitative analytical description and computation of the spatial structure of the reflected beam for large and small distances between the spherical-wave source and the crystal are performed. The mechanism of much more efficient reflection of an X-ray beam by a deformed crystal in comparison with a perfect crystal is clearly demonstrated. It is also shown that the trajectory method is very convenient for description of the total reflection phenomenon

  2. Nonspecular reflection of light at an inhomogeneous interface between two media and in a nanostructured layer with a quasi-zero refractive index

    International Nuclear Information System (INIS)

    Gadomsky, O. N.; Gadomskaya, I. V.

    2015-01-01

    We have derived formulas for the amplitudes of light reflection and refraction at an inhomogeneous interface between two media and in a nanostructured layer with a quasi-zero refractive index. These formulas are applied to explain the experimental spectra of nonspecular light reflection using a nanostructured (PMMA + Ag) layer with silver nanoparticles on a silicon surface as an example. We show that a surface wave is formed in the nanostructured layer at various angles of light incidence and the layer with a quasi-zero refractive index is an antireflection coating that provides uniform 5% silicon antireflection in the wavelength range from 450 to 1000 nm

  3. Chlorine determination in (U, Pu)C fuel by total reflection X-ray fluorescence spectrometry

    International Nuclear Information System (INIS)

    Misra, Nand Lal; Dhara, Sangita; Mudher, Khush Dev Singh; Aggarwal, Suresh K.; Thakur, Uday Kumar; Shah, Dipti; Sawant, R.M.; Ramakumar, K.L.

    2007-01-01

    A Total Reflection X-ray Fluorescence (TXRF) method for the determination of chlorine in (U,Pu)C has been developed. The method involves calibration of the instrument with standard solutions and validation of TXRF determination of chlorine using synthetic standard solutions. Cl K α line excited with W L α source was used for TXRF determinations of chlorine. Chlorine present in trace amounts in (U,Pu)C samples was first separated by pyro hydrolysis. The evolved chlorine, in form of HCl, was collected in 5 mM NaOH solution. This solution was analyzed for chlorine by Total Reflection X-ray Fluorescence Spectrometry using cobalt as an internal standard. The TXRF detection limit of chlorine was found to be 3.6 pg with sample size of 30 μL. In order to assess the applicability of TXRF method for chlorine determinations in other nuclear materials, one U 3 O 8 trace element standard was also analyzed for chlorine in similar way. The precision of the method was found to be 25% (1 σ) at ng level in most of the cases. (author)

  4. Improvements in in-situ filter test methods using a total light-scattering detector

    International Nuclear Information System (INIS)

    Marshall, M.; Stevens, D.C.

    1986-01-01

    This paper presents research aimed at providing useful data on a commonly used technique; a DOP (di-2-ethylhexyl phthalate) aerosol and a total light-scattering photometer. Methods of increasing the sensitivity of this technique are described. Alternative methods of in-situ filter testing are also considered. The sensitivity of a typical, modern, total light-scattering photometer, as a function of particle diameter, has a broad maximum in mass terms between 0.1 and 0.4 um. At its maximum usable sensitivity the instrument can detect approx. 1 particle/cm 3 . This response can be explained by light scattering theory and particle loss in the instrument inlet. The mass median diameter of the aerosols produced by various DOP generators varies from 0.2 to 1.0μm. Experiments with good quality HEPA filters indicate a maximum penetration for particles of 0.15 - 0.2μm. Details of the studies are given and the consequences discussed. It is shown that filter penetration of -3 % can be measured in-situ with existing equipment. Methods of extending the sensitivity to measure a penetration of approx.10 -5 % are described. (author)

  5. Detecting Close-In Extrasolar Giant Planets with the Kepler Photometer via Scattered Light

    Science.gov (United States)

    Jenkins, J. M.; Doyle, L. R.; Kepler Discovery Mission Team

    2003-05-01

    NASA's Kepler Mission will be launched in 2007 primarily to search for transiting Earth-sized planets in the habitable zones of solar-like stars. In addition, it will be poised to detect the reflected light component from close-in extrasolar giant planets (CEGPs) similar to 51 Peg b. Here we use the DIARAD/SOHO time series along with models for the reflected light signatures of CEGPs to evaluate Kepler's ability to detect such planets. We examine the detectability as a function of stellar brightness, stellar rotation period, planetary orbital inclination angle, and planetary orbital period, and then estimate the total number of CEGPs that Kepler will detect over its four year mission. The analysis shows that intrinsic stellar variability of solar-like stars is a major obstacle to detecting the reflected light from CEGPs. Monte Carlo trials are used to estimate the detection threshold required to limit the total number of expected false alarms to no more than one for a survey of 100,000 stellar light curves. Kepler will likely detect 100-760 51 Peg b-like planets by reflected light with orbital periods up to 7 days. LRD was supported by the Carl Sagan Chair at the Center for the Study of Life in the Universe, a division of the SETI Institute. JMJ received support from the Kepler Mission Photometer and Science Office at NASA Ames Research Center.

  6. Anti-reflective coating for visible light using a silver nanodisc metasurface with a refractive index of less than 1.0

    Science.gov (United States)

    Yasuda, Hideki; Matsuno, Ryo; Koito, Naoki; Hosoda, Hidemasa; Tani, Takeharu; Naya, Masayuki

    2017-12-01

    Suppression of visible-light reflection from material surfaces is an important technology for many applications such as flat-panel displays, camera lenses, and solar panels. In this study, we developed an anti-reflective coating design based on a silver nanodisc metasurface. The effective refractive index of a 10-nm-thick monolayer of silver nanodiscs was less than 1.0, which enabled strong suppression of reflection from the underlying substrate. The nanodisc structure was easy to fabricate using a conventional roll-to-roll wet-coating method. The anti-reflective structure was fabricated over a large area.

  7. Photosynthetic light reactions increase total lipid accumulation in carbon-supplemented batch cultures of Chlorella vulgaris.

    Science.gov (United States)

    Woodworth, Benjamin D; Mead, Rebecca L; Nichols, Courtney N; Kolling, Derrick R J

    2015-03-01

    Microalgae are an attractive biofuel feedstock because of their high lipid to biomass ratios, lipid compositions that are suitable for biodiesel production, and the ability to grow on varied carbon sources. While algae can grow autotrophically, supplying an exogenous carbon source can increase growth rates and allow heterotrophic growth in the absence of light. Time course analyses of dextrose-supplemented Chlorella vulgaris batch cultures demonstrate that light availability directly influences growth rate, chlorophyll production, and total lipid accumulation. Parallel photomixotrophic and heterotrophic cultures grown to stationary phase reached the same amount of biomass, but total lipid content was higher for algae grown in the presence of light (an average of 1.90 mg/mL vs. 0.77 mg/mL over 5 days of stationary phase growth). Copyright © 2014 Elsevier Ltd. All rights reserved.

  8. Far-ultraviolet spectral changes of titanium dioxide with gold nanoparticles by ultraviolet and visible light

    Science.gov (United States)

    Tanabe, Ichiro; Kurawaki, Yuji

    2018-05-01

    Attenuated total reflectance spectra including the far-ultraviolet (FUV, ≤ 200 nm) region of titanium dioxide (TiO2) with and without gold (Au) nanoparticles were measured. A newly developed external light-irradiation system enabled to observe spectral changes of TiO2 with Au nanoparticles upon light irradiations. Absorption in the FUV region decreased and increased by the irradiation with ultraviolet and visible light, respectively. These spectral changes may reflect photo-induced electron transfer from TiO2 to Au nanoparticles under ultraviolet light and from Au nanoparticles to TiO2 under visible light, respectively.

  9. Searching for reflected light from τ Bootis b with high-resolution ground-based spectroscopy: Approaching the 10-5 contrast barrier

    Science.gov (United States)

    Hoeijmakers, H. J.; Snellen, I. A. G.; van Terwisga, S. E.

    2018-02-01

    Context. It is challenging to measure the starlight reflected from exoplanets because of the extreme contrast with their host stars. For hot Jupiters, this contrast is in the range of 10-6 to 10-4, depending on their albedo, radius and orbital distance. Searches for reflected light have been performed since the first hot Jupiters were discovered, but with very limited success because hot Jupiters tend to have low albedo values due to the general absence of reflective cloud decks. Aim. The aim of this study is to search for reflected light from τ Boo b, a hot Jupiter with one of the brightest host stars. Since its discovery in 1997, it has been the subject of several reflected-light searches using high-dispersion spectroscopy. Here we aim to combine these data in to a single meta-analysis. Methods: We analysed more than 2000 archival high-dispersion spectra obtained with the UVES, ESPaDOnS, NARVAL UES and HARPS-N spectrographs during various epochs between 1998 and 2013. Each spectrum was first cleaned of the stellar spectrum and subsequently cross-correlated with a PHOENIX model spectrum. These were then Doppler shifted to the planet rest-frame and co-added in time, weighted according to the expected signal-to-noise of the planet signal. Results: We reach a 3σ upper limit of the planet-to-star contrast of 1.5 × 10-5. Assuming a planet radius of 1.15 RJ, this corresponds to an optical albedo of between 400-700 nm. A low albedo is in line with secondary eclipse and phase curve observations of other hot Jupiters using space-based observatories, as well as theoretical predictions of their reflective properties.

  10. Light mirror reflection combined with heating/cooling curves as a method of studying phase transitions in transparent and opaque petroleum products: Apparatus and theory

    International Nuclear Information System (INIS)

    Shishkin, Yu.L.

    2007-01-01

    A portable low weight low cost apparatus 'Phasafot' and method for determining pour and cloud points of petroleum products, as well as precipitation and melting temperatures of paraffins in both transparent (diesel fuels), semi-transparent (lube oils) and opaque (crude oils) samples are described. The method consists in illuminating the surface of a sample with an oblique light beam and registering the intensity of specularly reflected light while heating/cooling the sample in the temperature range of its structural transitions. The mirror reflection of a light beam from an ideally smooth liquid surface falls in intensity when the surface becomes rough (dim) due to crystal formation. Simultaneous recording of the temperature ramp curve and the mirror reflection curve enables the determination of the beginning and end of crystallization of paraffins in both transparent and opaque petroleum products. Besides, their rheological properties can be accurately determined by rocking or tilting the instrument while monitoring the sample movement via its mirror reflection

  11. Inorganic pigment study of the San Pedro Gonzalez Telmo Sibyls using total reflection X-ray fluorescence

    International Nuclear Information System (INIS)

    Vazquez, Cristina; Custo, Graciela; Barrio, Nestor; Burucua, Jose; Boeykens, Susana; Marte, Fernando

    2010-01-01

    This article describes the study carried out on a series of oil paintings on canvas from the eighteenth century that were restored at Centro de Produccion e Investigacion en Restauracion y Conservacion Artistica y Bibliografica - Tarea (CEIRCAB-Tarea), Buenos Aires, Argentina: the San Pedro Gonzalez Telmo Sibyls. Experimental study was undertaken to identify inorganic pigments and the technique used in their confection; and, in this way, try to add information about their local origin. Therefore special emphasis was put to infer technologies used in the manufacturing of these paintings. Elemental analysis was performed by total reflection X-ray fluorescence spectrometry (TXRF) and complemented by optical and polarized light microscopy. Microsampling was carefully done over areas of the paintings which were damaged and where a small additional loss will not be noticed. This investigation has shown that a variety of pigments were used, namely earth pigments (red and yellow ochres), white lead, vermilion, etc., and they were used either pure or in mixtures. This characterization helped conservators in their decisions regarding a better understanding of the deterioration processes. In addition, this research about the material composition allowed the art historians and restorers the possibility to obtain information about where, when or by whom The San Pedro Gonzalez Telmo Sibyls may have been painted.

  12. Inorganic pigment study of the San Pedro Gonzalez Telmo Sibyls using total reflection X-ray fluorescence

    Energy Technology Data Exchange (ETDEWEB)

    Vazquez, Cristina, E-mail: vazquez@cnea.gov.a [Universidad de Buenos Aires, Facultad de Ingenieria, Paseo Colon 850. C1063ACU, Buenos Aires (Argentina); Comision Nacional de Energia Atomica, Gerencia Quimica, Av. Gral Paz 1499, B1650KNA, San Martin (Argentina); Custo, Graciela, E-mail: custo@cnea.gov.a [Comision Nacional de Energia Atomica, Gerencia Quimica, Av. Gral Paz 1499, B1650KNA, San Martin (Argentina); Barrio, Nestor, E-mail: nbarrio@unsam.edu.a [CEIRCAB-TAREA, Universidad Nacional de San Martin (UNSAM), Escuela de Humanidades, Campus Miguelete, 25 de Mayo y Francia, B1650KNA, San Martin (Argentina); Burucua, Jose, E-mail: gburucua@unsam.edu.a [CEIRCAB-TAREA, Universidad Nacional de San Martin (UNSAM), Escuela de Humanidades, Campus Miguelete, 25 de Mayo y Francia, B1650KNA, San Martin (Argentina); Boeykens, Susana [Universidad de Buenos Aires, Facultad de Ingenieria, Paseo Colon 850. C1063ACU, Buenos Aires (Argentina); Marte, Fernando, E-mail: fmarte@unsam.edu.a [CEIRCAB-TAREA, Universidad Nacional de San Martin (UNSAM), Escuela de Humanidades, Campus Miguelete, 25 de Mayo y Francia, B1650KNA, San Martin (Argentina)

    2010-09-15

    This article describes the study carried out on a series of oil paintings on canvas from the eighteenth century that were restored at Centro de Produccion e Investigacion en Restauracion y Conservacion Artistica y Bibliografica - Tarea (CEIRCAB-Tarea), Buenos Aires, Argentina: the San Pedro Gonzalez Telmo Sibyls. Experimental study was undertaken to identify inorganic pigments and the technique used in their confection; and, in this way, try to add information about their local origin. Therefore special emphasis was put to infer technologies used in the manufacturing of these paintings. Elemental analysis was performed by total reflection X-ray fluorescence spectrometry (TXRF) and complemented by optical and polarized light microscopy. Microsampling was carefully done over areas of the paintings which were damaged and where a small additional loss will not be noticed. This investigation has shown that a variety of pigments were used, namely earth pigments (red and yellow ochres), white lead, vermilion, etc., and they were used either pure or in mixtures. This characterization helped conservators in their decisions regarding a better understanding of the deterioration processes. In addition, this research about the material composition allowed the art historians and restorers the possibility to obtain information about where, when or by whom The San Pedro Gonzalez Telmo Sibyls may have been painted.

  13. Monitoring of the environmental pollution by trace element analysis in tree-rings using synchrotron radiation total reflection X-ray fluorescence

    Energy Technology Data Exchange (ETDEWEB)

    Sirito de Vives, Ana Elisa [School of Civil Engineering, Architecture and Urban Design Methodist University of Piracicaba, Rodovia Santa Barbara D' Oeste/Iracemapolis, km 01, 13450-000 Santa Barbara D' Oeste, SP (Brazil)]. E-mail: aesvives@unimep.br; Moreira, Silvana [State University of Campinas - UNICAMP/FEC (Brazil); Brienza, Sandra Maria Boscolo [School of Civil Engineering, Architecture and Urban Design Methodist University of Piracicaba, Rodovia Santa Barbara D' Oeste/Iracemapolis, km 01, 13450-000 Santa Barbara D' Oeste, SP (Brazil); Silva Medeiros, Jean Gabriel [University of Sao Paulo - USP/ ESALQ (Brazil); Tomazello Filho, Mario Tomazello [University of Sao Paulo - USP/ ESALQ (Brazil); Araujo Domingues Zucchi, Orgheda Luiza [University of Sao Paulo - USP/FCFRP (Brazil); Nascimento Filho, Virgilio Franco do [University of Sao Paulo - USP/CENA (Brazil)

    2006-11-15

    This paper aims to study the environmental pollution in the tree development, in order to evaluate its use as bioindicator in urban and country sides. The sample collection was carried out in Piracicaba city, Sao Paulo State, which presents high level of environmental contamination in water, soil and air, due to industrial activities, vehicles combustion, sugar-cane leaves burning in the harvesting, etc. The species Caesalpinia peltophoroides ('Sibipiruna') was selected because it is widely used in urban forestation. Synchrotron Radiation Total Reflection X-ray Fluorescence technique (SR-TXRF) was employed to identify and quantify the elements and metals of nutritional and toxicological importance in the wood samples. The analysis was performed in the Brazilian Synchrotron Light Source Laboratory, using a white beam for excitation and a Si(Li) detector for X-ray detection. In several samples, P, K, Ca, Ti, Fe, Sr, Ba and Pb were quantified. The K/Ca, K/P and Pb/Ca ratios were found to decrease towards the bark.

  14. Monitoring of the environmental pollution by trace element analysis in tree-rings using synchrotron radiation total reflection X-ray fluorescence

    International Nuclear Information System (INIS)

    Sirito de Vives, Ana Elisa; Moreira, Silvana; Brienza, Sandra Maria Boscolo; Silva Medeiros, Jean Gabriel; Tomazello Filho, Mario Tomazello; Araujo Domingues Zucchi, Orgheda Luiza; Nascimento Filho, Virgilio Franco do

    2006-01-01

    This paper aims to study the environmental pollution in the tree development, in order to evaluate its use as bioindicator in urban and country sides. The sample collection was carried out in Piracicaba city, Sao Paulo State, which presents high level of environmental contamination in water, soil and air, due to industrial activities, vehicles combustion, sugar-cane leaves burning in the harvesting, etc. The species Caesalpinia peltophoroides ('Sibipiruna') was selected because it is widely used in urban forestation. Synchrotron Radiation Total Reflection X-ray Fluorescence technique (SR-TXRF) was employed to identify and quantify the elements and metals of nutritional and toxicological importance in the wood samples. The analysis was performed in the Brazilian Synchrotron Light Source Laboratory, using a white beam for excitation and a Si(Li) detector for X-ray detection. In several samples, P, K, Ca, Ti, Fe, Sr, Ba and Pb were quantified. The K/Ca, K/P and Pb/Ca ratios were found to decrease towards the bark

  15. Monitoring environmental pollution of trace elements in tree-rings by synchrotron radiation total reflection X-ray fluorescence analysis (SR-TXRF)

    Energy Technology Data Exchange (ETDEWEB)

    Moreira, Silvana [Universidade Estadual de Campinas, SP (Brazil). Faculdade de Engenharia Civil, Arquitetura e Urbanismo]. E-mail: Silvana@fec.unicamp.br; Vives, Ana Elisa S. de [Universidade Metodista de Piracicaba (UNIMEP), Santa Barbara D' Oeste, SP (Brazil). Faculdade de Engenharia, Arquitetura e Urbanismo]. E-mail: aesvives@unimep.br; Brienza, Sandra Maria B. [Universidade Metodista de Piracicaba (UNIMEP), Santa Barbara D' Oeste, SP (Brazil) Faculdade de Ciencias Matematicas, da Natureza e de Tecnologia da Informacao]. E-mail: sbrienza@unimep.br; Medeiros, Jean Gabriel S.; Tomazello Filho, Mario [Sao Paulo Univ., Piracicaba, SP (Brazil). Escola Superior de Agricultura Luiz de Queiroz]. E-mail: jeangm@esalq.usp.br; mtomazel@esalq.usp.br; Zucchi, Orgheda L.A.D. [Sao Paulo Univ., Ribeirao Preto, SP (Brazil). Faculdade de Ciencias Farmaceuticas]. E-mail: olzucchi@fcfrp.usp.br; Nascimento Filho, Virgilio F. [Centro de Energia Nuclear na Agricultura (CENA), Piracicaba, SP (Brazil). Lab. de Instrumentacao Nuclear]. E-mail: virgilio@cena.usp.br

    2005-07-01

    This paper aims to study the environmental pollution in the tree development, as a manner to evaluate its use as bioindicator in urban and country sides. The sample collecting was carry out in Piracicaba city, Sao Paulo State, that presents high level of environmental contamination of the water, soil and air, due industrial activities, vehicles combustion, sugar-cane leaves burning in the harvesting, etc. It was selected the Caesalpinia peltophoroides ('Sibipiruna') specie because its very used in urban arborization. It was employed the analytical technique named total reflection X-ray fluorescence (TXRF) to identify and quantify the elements and metals of nutritional and toxicological importance in the wood samples. The analysis was done in the Brazilian Synchrotron Light Laboratory, using a white beam for excitation and a Si(Li) detector for characteristic X-ray detection. It was quantified the P, K, Ca, Ti, Fe, Sr, Ba e Pb elements. (author)

  16. The role of total-reflection x-ray fluorescence in atomic spectroscopy

    International Nuclear Information System (INIS)

    Toelg, G.; Klockenkaemper, R.

    1993-01-01

    Total-reflection X-ray fluorescence (TXRF) is a universal and economic method for the simultaneous determination of elements with atomic numbers > 11 down to the lower pg-level. It is a microanalytical tool for the analysis of small sample amounts placed on flat carriers and for contaminations on flat sample surfaces. Analyses of stratified near-surface layers are made possible by varying the incident angle of the primary beam in the region of total-reflection. This non-destructive method is especially suitable for thin layers of a few nanometres, deposited on wafer material although not usable as a microprobe method with a high lateral resolution. Furthermore, depth profiles of biological samples can be recorded by means of microtome sectioning of only a few micrometres, as, for example in the gradient analysis of human organs. In addition to micro- and surface-layer analysis, TXRF is effectively applied to element trace analysis. Homogeneous solutions, for example aqueous solutions, high-purity acids or body fluids, are pipetted onto carriers and, after evaporation, the dry residues are analyzed directly down to the pg/ml region. Particularly advantageous is the absence of matrix effects, so that an easy calibration can be carried out by adding a single internal standard element. A digestion or separation step preceding the actual determination becomes necessary if a more complex matrix is to be analysed or especially low detection limits have to be reached. A critical evaluation of the recent developments in atomic spectroscopy places TXRF in a leading position. Its outstanding features compete with those of e.g. electrothermal atomic absorption spectrometry (ETAAS), microwave induced plasma optical emission spectroscopy (MIP-OES) and inductively coupled plasma mass spectrometry (ICP-MS) in the field of micro- and trace analysis and with Rutherford backscattering (RBS) and secondary ion mass spectrometry (SIMS) in the surface-layer analysis. (author)

  17. Biomimetic light-harvesting funnels for re-directioning of diffuse light.

    Science.gov (United States)

    Pieper, Alexander; Hohgardt, Manuel; Willich, Maximilian; Gacek, Daniel Alexander; Hafi, Nour; Pfennig, Dominik; Albrecht, Andreas; Walla, Peter Jomo

    2018-02-14

    Efficient sunlight harvesting and re-directioning onto small areas has great potential for more widespread use of precious high-performance photovoltaics but so far intrinsic solar concentrator loss mechanisms outweighed the benefits. Here we present an antenna concept allowing high light absorption without high reabsorption or escape-cone losses. An excess of randomly oriented pigments collects light from any direction and funnels the energy to individual acceptors all having identical orientations and emitting ~90% of photons into angles suitable for total internal reflection waveguiding to desired energy converters (funneling diffuse-light re-directioning, FunDiLight). This is achieved using distinct molecules that align efficiently within stretched polymers together with others staying randomly orientated. Emission quantum efficiencies can be >80% and single-foil reabsorption energy funneling, dipole re-orientation, and ~1.5-2 nm nearest donor-acceptor transfer occurs within hundreds to ~20 ps. Single-molecule 3D-polarization experiments confirm nearly parallel emitters. Stacked pigment selection may allow coverage of the entire solar spectrum.

  18. Bidirectional reflectance distribution function /BRDF/ measurements of stray light suppression coatings for the Space Telescope /ST/

    Science.gov (United States)

    Griner, D. B.

    1979-01-01

    The paper considers the bidirectional reflectance distribution function (BRDF) of black coatings used on stray light suppression systems for the Space Telescope (ST). The ST stray light suppression requirement is to reduce earth, moon, and sun light in the focal plane to a level equivalent to one 23 Mv star per square arcsecond, an attenuation of 14 orders of magnitude. It is impractical to verify the performance of a proposed baffle system design by full scale tests because of the large size of the ST, so that a computer analysis is used to select the design. Accurate computer analysis requires a knowledge of the diffuse scatter at all angles from the surface of the coatings, for all angles of incident light. During the early phases of the ST program a BRDF scanner was built at the Marshall Space Flight Center to study the scatter from black materials; the measurement system is described and the results of measurements on samples proposed for use on the ST are presented.

  19. Total reflection X-ray fluorescence analysis with synchrotron radiation monochromatized by multilayer structures

    International Nuclear Information System (INIS)

    Rieder, R.; Wobrauschek, P.; Ladisich, W.; Streli, C.; Aiginger, H.; Garbe, S.; Gaul, G.; Knoechel, A.; Lechtenberg, F.

    1995-01-01

    To achieve lowest detection limits in total reflection X-ray fluorescence analysis (TXRF) synchrotron radiation has been monochromatized by a multilayer structure to obtain a relative broad energy band compared to Bragg single crystals for an efficient excitation. The energy has been set to 14 keV, 17.5 keV, 31 keV and about 55 keV. Detection limits of 20 fg and 150 fg have been achieved for Sr and Cd, respectively. ((orig.))

  20. Impurities determination in uranium eluates by total reflection X-ray fluorescence

    International Nuclear Information System (INIS)

    Vazquez, Cristina; Bellavigna, Horacio J.; Eppis, Maria R.; Ramella, Jose L.

    1999-01-01

    The chemical control of impurities in nuclear materials is indispensable in order to assure an efficient operation of the reactors. The maximum concentration admitted depends of the elements and in most cases are in the parts per billion range. Conventional analytical methods require a pre-concentration treatment of the sample and a previous separation of the matrix (uranium). This paper investigates the use of the total reflection X-ray fluorescence as an alternative methodology for the determination of impurities in nuclear materials, namely K, Ca, Ti, Cr, Mn, Fe, Ni, Cu and As. The detection limits obtained were in the range of 0.1 to 20 ng/ml for a 1000 seconds counting time. (author)

  1. Using the combination refraction-reflection solid to design omni-directional light source used in underwater wireless optical communication

    Science.gov (United States)

    Rao, Jionghui; Yao, Wenming; Wen, Linqiang

    2015-10-01

    Underwater wireless optical communication is a communication technology which uses laser as an information carrier and transmits data through water. Underwater wireless optical communication has some good features such as broader bandwidth, high transmission rate, better security, anti—interference performance. Therefore, it is promising to be widely used in the civil and military communication domains. It is also suitable for high-speed, short-range communication between underwater mobile vehicles. This paper presents a design approach of omni-directional light source used in underwater wireless optical communication, using TRACEPRO simulation tool to help design a combination solid composed of the lens, conical reflector and parabolic reflector, and using the modulated DPSS green laser in the transmitter module to output the laser beam in small divergence angles, after expanded by the combination refraction-reflection solid, the angle turns into a space divergence angle of 2π, achieving the omni-directional light source of hemisphere space, and test in the air and underwater, the result shows that the effect is fine. This paper analyzes the experimental test in the air and water, in order to make further improvement of the uniformity of light distribution, we optimize the reflector surface parameters of combination refraction-reflection solid and test in the air and water. The result shows that omni-directional light source used in underwater wireless optical communication optimized could achieve the uniformity of light distribution of underwater space divergence angle of 2π. Omni-directional light source used in underwater wireless optical communication designed in this paper has the characteristics of small size and uniformity of light distribution, it is suitable for application between UUVs, AUVs, Swimmer Delivery Vehicles (SDVs) and other underwater vehicle fleet, it realizes point-to-multipoint communications.

  2. Total number albedo and average cosine of the polar angle of low-energy photons reflected from water

    Directory of Open Access Journals (Sweden)

    Marković Srpko

    2007-01-01

    Full Text Available The total number albedo and average cosine of the polar angle for water and initial photon energy range from 20 keV to 100 keV are presented in this pa per. A water shield in the form of a thick, homogenous plate and per pendicular incidence of the monoenergetic photon beam are assumed. The results were obtained through Monte Carlo simulations of photon reflection by means of the MCNP computer code. Calculated values for the total number albedo were compared with data previously published and good agreement was confirmed. The dependence of the average cosine of the polar angle on energy is studied in detail. It has been found that the total average cosine of the polar angle has values in the narrow interval of 0.66-0.67, approximately corresponding to the reflection angle of 48°, and that it does not depend on the initial photon energy.

  3. Elemental concentration analysis in the brain of young and old Wistar rats by total reflection X-ray fluorescence spectrometry

    International Nuclear Information System (INIS)

    Serpa, Renata F.B.; Jesus, Edgar F.O. de; Lopes, Ricardo T.; Anjos, Marcelino J. dos; Carmo, Maria G.T. do; Rocha, Monica S.; Moreira, Silvana; Martinez, Ana M.B.

    2007-01-01

    It is well known that aging is associated with neurobehavioral deficits. The aging process of human brain is characterized by progressive neuronal loss. Furthermore, certain brain areas are more vulnerable to neuronal degeneration than others, reflecting an altered resistance to stress of the tissue itself and/or the lack of adequate immunological defense mechanisms in these regions. About the elemental levels in the brain, it is known that the excess ou deficiency of some elements are toxic for human healthy, being also related to several neurodegenerative diseases. In this way, the main goal of this work was to determine the elemental concentration in the hippocampus of young and old male (n = 10) and female (n = 10) Wistar rats by total reflection X-ray fluorescence spectrometry with synchrotron radiation (SR-TXRF). These measurements were carried out at XRF beam line at Light Synchrotron Brazilian Laboratory, Campinas, Brazil. About the results, we could observe that Al, Fe, Cu, Zn and Br levels were higher in the hippocampus of the old female rats than the young ones. On the other hand, only Cu levels were higher in the hippocampus of the old male rats than the young ones. Therefore, the aging of the hippocampus of the female rats can be characterized by an accumulate for Al, Fe, Cu, Zn and Br. The excess in these elements levels are also associated with several neurodegenerative disorders, such as Alzheimer' disease, Parkinson's disease and Huntington's disease. (author)

  4. Total reflection x-ray analysis of metals in blood samples

    International Nuclear Information System (INIS)

    Nakamura, Takuya; Matsui, Hiroshi; Kawamata, Masaya

    2009-01-01

    The sample preparation for TXRF (total reflection X-ray fluorescence) quantitative analysis of trace elements in human blood samples was investigated. In the TXRF analysis, a solution sample is dropped and dried on a flat substrate, and then the dried residue is measured. In this case, the dried residue should be flat not to disturb X-ray total reflection on the substrate. In addition, it is required to simply measure the whole blood sample by TXRF method, although a serum is analyzed in many cases. Thus, we studied the optimum conditions of the sample preparation of the whole blood by adding the pure water to apply Hemolysis phenomenon, where blood cells are destroyed due to different of the osmotic pressure, leading to flat residue. It was found that the best S/B ratio was obtained when the whole blood was diluted 8 times with pure water. Moreover, it was investigated the influence of the surface chemical condition of the glass substrate on the shape of the dried reside of the blood sample. When the surface of the glass substrate was hydrophilic, the shape of the dried residues was not uniform, as a result, the quantitative data of TXRF analysis gave a large deviation. On the other hand, when the surface of the glass was hydrophobic, the shape of the residue was almost uniform, as a result, a good reproducibility was obtained. Another problem was an outer ring of the dried residue of the blood. This uneven ring absorbs the primary X-rays, caused to low determined quantitative data. Thus, we tried the heating way of the dropped blood sample at a high temperature of 200 degrees. In this case, the blood sample was dried immediately, and a flat homogeneous dried residue was obtained without the outer ring. Using the optimized conditions for sample preparation, human blood sample was quantitatively measured by TXRF and ICP-AES. A good agreement was obtained in TXRF and ICP-AES determinations; however, the measurement of Cl and Br will be an advantage of TXRF, because

  5. Low-temperature relative reflectivity measurements of reflective and scintillating foils used in rare event searches

    Science.gov (United States)

    Langenkämper, A.; Ulrich, A.; Defay, X.; Feilitzsch, F. v.; Lanfranchi, J.-C.; Mondragón, E.; Münster, A.; Oppenheimer, C.; Potzel, W.; Roth, S.; Schönert, S.; Steiger, H.; Trinh Thi, H. H.; Wawoczny, S.; Willers, M.; Zöller, A.

    2018-03-01

    In this work we investigate the reflectivity of highly reflective multilayer polymer foils used in the CRESST experiment. The CRESST experiment searches directly for dark matter via operating scintillating CaWO4 crystals as targets for elastic dark matter-nucleon scattering. In order to suppress background events, the experiment employs the so-called phonon-light technique which is based on the simultaneous measurement of the heat signal in the main CaWO4 target crystal and of the emitted scintillation light with a separate cryogenic light detector. Both detectors are surrounded by a highly reflective and scintillating multilayer polymer foil to increase the light collection efficiency and to veto surface backgrounds. While this study is motivated by the CRESST experiment, the results are also relevant for other rare event searches using scintillating cryogenic bolometers in the field of the search of dark matter and neutrinoless double beta decay (0 νββ). In this work a dedicated experiment has been set up to determine the relative reflectivity at 300 K and 20 K of three multilayer foils ("VM2000", "VM2002", "Vikuiti") produced by the company 3M. The intensity of a light beam reflected off the foil is measured with a CCD camera. The ratio of the intensities at 300 K and 20 K corresponds to the relative reflectivity change. The measurements performed in this work show no variation of the reflectivity with temperature at a level of ∼1%.

  6. Light-reflection random-target method for measurement of the modulation transfer function of a digital video-camera

    Czech Academy of Sciences Publication Activity Database

    Pospíšil, Jaroslav; Jakubík, P.; Machala, L.

    2005-01-01

    Roč. 116, - (2005), s. 573-585 ISSN 0030-4026 Institutional research plan: CEZ:AV0Z10100522 Keywords : random-target measuring method * light-reflection white - noise target * digital video camera * modulation transfer function * power spectral density Subject RIV: BH - Optics, Masers, Lasers Impact factor: 0.395, year: 2005

  7. Generating structured light with phase helix and intensity helix using reflection-enhanced plasmonic metasurface at 2 μm

    Science.gov (United States)

    Zhao, Yifan; Du, Jing; Zhang, Jinrun; Shen, Li; Wang, Jian

    2018-04-01

    Mid-infrared (2-20 μm) light has been attracting great attention in many areas of science and technology. Beyond the extended wavelength range from visible and near-infrared to mid-infrared, shaping spatial structures may add opportunities to grooming applications of mid-infrared photonics. Here, we design and fabricate a reflection-enhanced plasmonic metasurface and demonstrate efficient generation of structured light with the phase helix and intensity helix at 2 μm. This work includes two distinct aspects. First, structured light (phase helix, intensity helix) generation at 2 μm, which is far beyond the ability of conventional spatial light modulators, is enabled by the metasurface with sub-wavelength engineered structures. Second, the self-referenced intensity helix against environmental noise is generated without using a spatially separated light. The demonstrations may open up advanced perspectives to structured light applications at 2 μm, such as phase helix for communications and non-communications (imaging, sensing) and intensity helix for enhanced microscopy and advanced metrology.

  8. Total internal reflection fluorescence (TIRF) microscopy for real-time imaging of nanoparticle-cell plasma membrane interaction

    DEFF Research Database (Denmark)

    Parhamifar, Ladan; Moghimi, Seyed Moien

    2012-01-01

    Nanoparticulate systems are widely used for site-specific drug and gene delivery as well as for medical imaging. The mode of nanoparticle-cell interaction may have a significant effect on the pathway of nanoparticle internalization and subsequent intracellular trafficking. Total internal reflection...

  9. How Can Polarization States of Reflected Light from Snow Surfaces Inform Us on Surface Normals and Ultimately Snow Grain Size Measurements?

    Science.gov (United States)

    Schneider, A. M.; Flanner, M.; Yang, P.; Yi, B.; Huang, X.; Feldman, D.

    2016-12-01

    The Snow Grain Size and Pollution (SGSP) algorithm is a method applied to Moderate Resolution Imaging Spectroradiometer data to estimate snow grain size from space-borne measurements. Previous studies validate and quantify potential sources of error in this method, but because it assumes flat snow surfaces, however, large scale variations in surface normals can cause biases in its estimates due to its dependence on solar and observation zenith angles. To address these variations, we apply the Monte Carlo method for photon transport using data containing the single scattering properties of different ice crystals to calculate polarization states of reflected monochromatic light at 1500nm from modeled snow surfaces. We evaluate the dependence of these polarization states on solar and observation geometry at 1500nm because multiple scattering is generally a mechanism for depolarization and the ice crystals are relatively absorptive at this wavelength. Using 1500nm thus results in a higher number of reflected photons undergoing fewer scattering events, increasing the likelihood of reflected light having higher degrees of polarization. In evaluating the validity of the model, we find agreement with previous studies pertaining to near-infrared spectral directional hemispherical reflectance (i.e. black-sky albedo) and similarities in measured bidirectional reflectance factors, but few studies exist modeling polarization states of reflected light from snow surfaces. Here, we present novel results pertaining to calculated polarization states and compare dependences on solar and observation geometry for different idealized snow surfaces. If these dependencies are consistent across different ice particle shapes and sizes, then these findings could inform the SGSP algorithm by providing useful relationships between measurable physical quantities and solar and observation geometry to better understand variations in snow surface normals from remote sensing observations.

  10. Characterization and quantitative determination of calcium aluminate clinker phases through reflected light microscopy

    International Nuclear Information System (INIS)

    Marciano Junior, E.; Cunha Munhoz, F.A. da; Splettstoser Junior, J.; Placido, W.F.

    1989-01-01

    The identification and quantitative determination of phases in calcium aluminate clinker is of great importance to the producer, as it enables a better understanding of the cement and concrete properties, specially those concerning setting time and compressive strenght. Polished sections of three electrofused clinkers, one experimental and two industrial, were used to select the most suitable etchings in order to identify by microscopy the main phases (Ca, CA 2 , C 2 AS, C 12 A 7 , α-Al 2 O 3 ). Quantitative phases determinations by reflected light microscopy showed good results when compared to X-ray diffractometry measurements [pt

  11. On the tunneling of full-vector X-Waves through a slab under frustrated total reflection condition

    KAUST Repository

    Salem, Mohamed; Bagci, Hakan

    2012-01-01

    Tunneling of full-vector X-Waves through a dielectric slab under frustrated total reflection condition is investigated. Full-vector X-Waves are obtained by superimposing transverse electric and magnetic polarization components, which are derived from the scalar X-Wave solution. The analysis of reflection and transmission at the dielectric interfaces is carried out analytically in a straightforward fashion using vector Bessel beam expansion. Investigation of the fields propagating away from the farther end of the slab (transmitted fields) shows an advanced (superluminal) transmission of the X-Wave peak. Additionally, a similar advanced reflection is also observed. The apparent tunneling of the peak is shown to be due to the phase shift in the fields' spectra and not to be causally related to the incident peak. © 2012 IEEE.

  12. On the tunneling of full-vector X-Waves through a slab under frustrated total reflection condition

    KAUST Repository

    Salem, Mohamed

    2012-07-01

    Tunneling of full-vector X-Waves through a dielectric slab under frustrated total reflection condition is investigated. Full-vector X-Waves are obtained by superimposing transverse electric and magnetic polarization components, which are derived from the scalar X-Wave solution. The analysis of reflection and transmission at the dielectric interfaces is carried out analytically in a straightforward fashion using vector Bessel beam expansion. Investigation of the fields propagating away from the farther end of the slab (transmitted fields) shows an advanced (superluminal) transmission of the X-Wave peak. Additionally, a similar advanced reflection is also observed. The apparent tunneling of the peak is shown to be due to the phase shift in the fields\\' spectra and not to be causally related to the incident peak. © 2012 IEEE.

  13. Terahertz time-domain attenuated total reflection spectroscopy applied to the rapid discrimination of the botanical origin of honeys

    Science.gov (United States)

    Liu, Wen; Zhang, Yuying; Yang, Si; Han, Donghai

    2018-05-01

    A new technique to identify the floral resources of honeys is demanded. Terahertz time-domain attenuated total reflection spectroscopy combined with chemometrics methods was applied to discriminate different categorizes (Medlar honey, Vitex honey, and Acacia honey). Principal component analysis (PCA), cluster analysis (CA) and partial least squares-discriminant analysis (PLS-DA) have been used to find information of the botanical origins of honeys. Spectral range also was discussed to increase the precision of PLS-DA model. The accuracy of 88.46% for validation set was obtained, using PLS-DA model in 0.5-1.5 THz. This work indicated terahertz time-domain attenuated total reflection spectroscopy was an available approach to evaluate the quality of honey rapidly.

  14. Optical Reflectance Measurements for Commonly Used Reflectors

    Science.gov (United States)

    Janecek, Martin; Moses, William W.

    2008-08-01

    When simulating light collection in scintillators, modeling the angular distribution of optical light reflectance from surfaces is very important. Since light reflectance is poorly understood, either purely specular or purely diffuse reflectance is generally assumed. In this paper we measure the optical reflectance distribution for eleven commonly used reflectors. A 440 nm, output power stabilized, un-polarized laser is shone onto a reflector at a fixed angle of incidence. The reflected light's angular distribution is measured by an array of silicon photodiodes. The photodiodes are movable to cover 2pi of solid angle. The light-induced current is, through a multiplexer, read out with a digital multimeter. A LabVIEW program controls the motion of the laser and the photodiode array, the multiplexer, and the data collection. The laser can be positioned at any angle with a position accuracy of 10 arc minutes. Each photodiode subtends 6.3deg, and the photodiode array can be positioned at any angle with up to 10 arc minute angular resolution. The dynamic range for the current measurements is 10 5:1. The measured light reflectance distribution was measured to be specular for several ESR films as well as for aluminum foil, mostly diffuse for polytetrafluoroethylene (PTFE) tape and titanium dioxide paint, and neither specular nor diffuse for Lumirrorreg, Melinexreg and Tyvekreg. Instead, a more complicated light distribution was measured for these three materials.

  15. Light deflection and Gauss-Bonnet theorem: definition of total deflection angle and its applications

    Science.gov (United States)

    Arakida, Hideyoshi

    2018-05-01

    In this paper, we re-examine the light deflection in the Schwarzschild and the Schwarzschild-de Sitter spacetime. First, supposing a static and spherically symmetric spacetime, we propose the definition of the total deflection angle α of the light ray by constructing a quadrilateral Σ^4 on the optical reference geometry M^opt determined by the optical metric \\bar{g}_{ij}. On the basis of the definition of the total deflection angle α and the Gauss-Bonnet theorem, we derive two formulas to calculate the total deflection angle α ; (1) the angular formula that uses four angles determined on the optical reference geometry M^opt or the curved (r, φ ) subspace M^sub being a slice of constant time t and (2) the integral formula on the optical reference geometry M^opt which is the areal integral of the Gaussian curvature K in the area of a quadrilateral Σ ^4 and the line integral of the geodesic curvature κ _g along the curve C_{Γ}. As the curve C_{Γ}, we introduce the unperturbed reference line that is the null geodesic Γ on the background spacetime such as the Minkowski or the de Sitter spacetime, and is obtained by projecting Γ vertically onto the curved (r, φ ) subspace M^sub. We demonstrate that the two formulas give the same total deflection angle α for the Schwarzschild and the Schwarzschild-de Sitter spacetime. In particular, in the Schwarzschild case, the result coincides with Epstein-Shapiro's formula when the source S and the receiver R of the light ray are located at infinity. In addition, in the Schwarzschild-de Sitter case, there appear order O(Lambda;m) terms in addition to the Schwarzschild-like part, while order O(Λ) terms disappear.

  16. Quality Control of Valerianae Radix by Attenuated Total Reflection Fourier Transform Infrared (ATR-FTIR) Spectroscopy.

    Science.gov (United States)

    Nikzad-Langerodi, Ramin; Arth, Katharina; Klatte-Asselmeyer, Valerie; Bressler, Sabine; Saukel, Johannes; Reznicek, Gottfried; Dobeš, Christoph

    2018-04-01

    (Acetoxy-)valerenic acid and total essential oil content are important quality attributes of pharmacy grade valerian root (Valerianae radix). Traditional analysis of these quantities is time-consuming and necessitates (harmful) solvents. Here we investigated an application of attenuated total reflection Fourier transform infrared spectroscopy for extractionless analysis of these quality attributes on a representative sample comprising 260 wild-crafted individuals covering the Central European taxonomic diversity of the Valeriana officinalis L. s. l. species aggregate with its three major ploidy cytotypes (i.e., di-, tetra- and octoploid). Calibration models were built by orthogonal partial least squares regression for quantitative analysis of (acetoxy-)valerenic acid and total essential oil content. For the latter, we propose a simplistic protocol involving apolar extraction followed by gas chromatography as a reference method for multivariate calibration in order to handle the analysis of samples taken from individual plants. We found good predictive ability of chemometric models for quantification of valerenic acid, acetoxyvalerenic acid, total sesquiterpenoid acid, and essential oil content with a root mean squared error of cross-validation of 0.064, 0.043, and 0.09 and root mean squared error of prediction of 0.066, 0.057, and 0.09 (% content), respectively. Orthogonal partial least squares discriminant analysis revealed good discriminability between the most productive phenotype (i.e., the octoploid cytotype) in terms of sesquiterpenoid acids, and the less productive ones (i.e., di- and tetraploid). All in all, our results demonstrate the application of attenuated total reflection Fourier transform infrared spectroscopy for rapid, extractionless estimation of the most important quality attributes of valerian root and minimally invasive identification of the most productive phenotype in terms of sesquiterpenoid acids. Georg Thieme Verlag KG Stuttgart · New

  17. Reflective and refractive objects for mixed reality.

    Science.gov (United States)

    Knecht, Martin; Traxler, Christoph; Winklhofer, Christoph; Wimmer, Michael

    2013-04-01

    In this paper, we present a novel rendering method which integrates reflective or refractive objects into a differential instant radiosity (DIR) framework usable for mixed-reality (MR) applications. This kind of objects are very special from the light interaction point of view, as they reflect and refract incident rays. Therefore they may cause high-frequency lighting effects known as caustics. Using instant-radiosity (IR) methods to approximate these high-frequency lighting effects would require a large amount of virtual point lights (VPLs) and is therefore not desirable due to real-time constraints. Instead, our approach combines differential instant radiosity with three other methods. One method handles more accurate reflections compared to simple cubemaps by using impostors. Another method is able to calculate two refractions in real-time, and the third method uses small quads to create caustic effects. Our proposed method replaces parts in light paths that belong to reflective or refractive objects using these three methods and thus tightly integrates into DIR. In contrast to previous methods which introduce reflective or refractive objects into MR scenarios, our method produces caustics that also emit additional indirect light. The method runs at real-time frame rates, and the results show that reflective and refractive objects with caustics improve the overall impression for MR scenarios.

  18. Determination Of Refractive Index And Reflectivity Of Thin Layer With Optical Absorption Method; PENENTUAN INDEKS BIAS DAN REFLEKTIVITAS LAPISAN TIPIS DENGAN METODA SERAPAN OPTIK

    Energy Technology Data Exchange (ETDEWEB)

    Hariyanto, Sigit; Budianto, Anwar; Subarkah,; Atmono, Trimarji [Yogyakarta Nuclear Research Center, National Nuclear Energy Agency, Yogyakarta (Indonesia)

    1996-04-15

    . The refractive index and reflectivity of ASi:H and Si Ox thin layer have been observed by optical absorption methods. Measurement has been done after the preparation of optical system which consists of a halogen lamp light source, monochromator, sample and light detector. The Monochromator output showed that measured halogen lamp spectrum light is between 470 nm -750 nm. The maximum voltage of halogen lamp is 220 Volt, the output light increases in intensity while the wave length increases. The inclination of intensity decrease at the wave length of 725 nm. The result of the calculation of refractive index varies in accordance with the wave length. The average refractive index of ASi:H is nf a = 1.753. The total reflectivity of air-thin layer-substrate is Rt a = 0.315. The refractive index of Si Ox sample is nf b2.182 and the total reflectivity is Rt b=O,514.

  19. submitter Measurement of LYSO Intrinsic Light Yield Using Electron Excitation

    CERN Document Server

    Martinez Turtos, Rosana; Pizzichemi, Marco; Ghezzi, Alessio; Pauwels, Kristof; Auffray, Etiennette; Lecoq, Paul; Paganoni, Marco

    2016-01-01

    The determination of the intrinsic light yield $(LY_{int})$ of scintillating crystals, i.e. number of optical photons created per amount of energy deposited, constitutes a key factor in order to characterize and optimize their energy and time resolution. However, until now measurements of this quantity are affected by large uncertainties and often rely on corrections for bulk absorption and surface/edge state. The novel idea presented in this contribution is based on the confinement of the scintillation emission in the central upper part of a 10 mm cubic crystal using a 1.5 MeV electron beam with diameter of 1 mm. A black non-reflective pinhole aligned with the excitation point is used to fix the light extraction solid angle (narrower than total reflection angle), which then sets a light cone travel path through the crystal. The final number of photoelectrons detected using a Hamamatsu R2059 photomultiplier tube (PMT) was corrected for the extraction solid angle, the Fresnel reflection coefficient and quantum...

  20. Mutual transformation of light waves by reflection holograms in photorefractive crystals of the 4-bar 3m symmetry

    Energy Technology Data Exchange (ETDEWEB)

    Naunyka, V. N.; Shepelevich, V. V., E-mail: vasshep@inbox.ru [Mozyr State Pedagogical University (Belarus)

    2011-05-15

    The mutual transformation of light waves in the case of their simultaneous diffraction from a bulk reflection phase hologram, which was formed in a cubic photorefractive crystal of the 4-bar 3m symmetry class, has been studied. The indicator surfaces of the polarization-optimized values of the relative intensity of the object wave, which make it possible to determine the amplification of this wave for any crystal cut, are constructed. The linear polarization azimuths at which the energy exchange between the light waves reaches a maximum are found numerically for crystals of different cuts.

  1. Determination of technetium by total reflection x-ray fluorescence

    International Nuclear Information System (INIS)

    Bermudez, J.I.; Greaves, E.D.; Nemeth, P.

    2000-01-01

    We describe a technique using total reflection x-ray fluorescence (TXRF) for determination of Technetium produced by elution of chromatography generators with physiological saline solutions. The analysis with the 18.41 keV K α line of Technetium was accomplished with monochromatized K α radiation from a silver anode x-ray tube operated at 45 keV and 20 mA. This radiation at 22.104 keV is efficiently coupled to the 21.054 keV absorption edge of Tc. It is also of advantage in the direct analysis of organic and saline properties of the Tc-bearing samples. Quantification was accomplished by internal standard addition of Ga and using an interpolated value of the sensitivity for Tc between Molybdenum and Rhenium. Data processing was carried out with the QXAS-AXIL software package. System sensitivity was found adequate for direct Tc determination of eluted saline solutions. The interest and advantages of the use of the technique as an auxiliary in the synthesis and characterization of Tc-labeled radiopharmaceuticals used for diagnosis in nuclear medicine are discussed. Detection limits in the matrices analyzed are reported. (author)

  2. Spectroscopic refractometer for transparent and absorbing liquids by reflection of white light near the critical angle

    International Nuclear Information System (INIS)

    Sánchez-Pérez, C.; García-Valenzuela, A.

    2012-01-01

    We propose and evaluate a spectroscopic refractometer device to measure the refractive index dispersion of transparent and absorbing solutions. The angle-dependent reflectivity of a white beam of light in an internal reflection configuration around the critical angle is spectrally analyzed. The refractive index in a wavelength range from 400 nm to 900 nm is obtained from the angle-reflectivity curve around the critical angle at each wavelength. The device does not use angle scanning mechanisms, decreasing considerably the complexity of the instrument in comparison to previous proposals. As a result, the measurements are obtained relatively fast. Nevertheless, a good experimental resolution in refractive index of about Δn ≈ 10 −4 at all the wavelengths is achieved in the case of transparent solutions. The calibration procedure of the device is discussed in detail. We also present measurements of the refractive index dispersion of rhodamine 6G-methanol solutions, which has a strong absorption band in the visible spectra.

  3. Analysis of total and dissolved heavy metals in surface water of a Mexican polluted river by total reflection X-ray fluorescence spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Zarazua, G. [Instituto Nacional de Investigaciones Nucleares, Gerencia de Ciencias Ambientales, Apartado Postal 18-1027, Mexico D.F., C.P. 11801 (Mexico)]. E-mail: gzo@nuclear.inin.mx; Avila-Perez, P. [Instituto Nacional de Investigaciones Nucleares, Gerencia de Ciencias Ambientales, Apartado Postal 18-1027, Mexico D.F., C.P. 11801 (Mexico); Tejeda, S. [Instituto Nacional de Investigaciones Nucleares, Gerencia de Ciencias Ambientales, Apartado Postal 18-1027, Mexico D.F., C.P. 11801 (Mexico); Barcelo-Quintal, I. [Universidad Autonoma Metropolitana, Unidad Azcapotzalco, Mexico, D.F. (Mexico); Martinez, T. [Universidad Nacional Autonoma de Mexico, Facultad de Quimica, Mexico, D.F. (Mexico)

    2006-11-15

    The present area of study is located in the Upper Course of the Lerma River (UCLR). The Lerma is one of the most important rivers of Mexico, where it drains highly populated and industrialized regions. The aim of the present study is to determine the heavy metal concentration of Cr, Mn, Fe, Cu and Pb in dissolved and total phases of the UCLR by means of Total Reflection X-ray Fluorescence Spectrometry (TXRF). The surface water samples were collected at 8 sites distributed following the stream flow direction of the river. Four sampling campaigns were carried out in each site in a 1-year period. A sample preparation method was applied in order to obtain the total and dissolved fraction and to destroy the organic matter. The total heavy metal average concentration decrease in the following order: Fe (2566 {mu}g/L) > Mn (300 {mu}g/L) > Cu (66 {mu}g/L) > Cr (21 {mu}g/L) > Pb (15 {mu}g/L). In general, the heavy metal concentrations in water of the UCLR are below the maximum permissible limits.

  4. Analysis of total and dissolved heavy metals in surface water of a Mexican polluted river by total reflection X-ray fluorescence spectrometry

    Science.gov (United States)

    Zarazua, G.; Ávila-Pérez, P.; Tejeda, S.; Barcelo-Quintal, I.; Martínez, T.

    2006-11-01

    The present area of study is located in the Upper Course of the Lerma River (UCLR). The Lerma is one of the most important rivers of Mexico, where it drains highly populated and industrialized regions. The aim of the present study is to determine the heavy metal concentration of Cr, Mn, Fe, Cu and Pb in dissolved and total phases of the UCLR by means of Total Reflection X-ray Fluorescence Spectrometry (TXRF). The surface water samples were collected at 8 sites distributed following the stream flow direction of the river. Four sampling campaigns were carried out in each site in a 1-year period. A sample preparation method was applied in order to obtain the total and dissolved fraction and to destroy the organic matter. The total heavy metal average concentration decrease in the following order: Fe (2566 μg/L) > Mn (300 μg/L) > Cu (66 μg/L) > Cr (21 μg/L) > Pb (15 μg/L). In general, the heavy metal concentrations in water of the UCLR are below the maximum permissible limits.

  5. Analysis of total and dissolved heavy metals in surface water of a Mexican polluted river by total reflection X-ray fluorescence spectrometry

    International Nuclear Information System (INIS)

    Zarazua, G.; Avila-Perez, P.; Tejeda, S.; Barcelo-Quintal, I.; Martinez, T.

    2006-01-01

    The present area of study is located in the Upper Course of the Lerma River (UCLR). The Lerma is one of the most important rivers of Mexico, where it drains highly populated and industrialized regions. The aim of the present study is to determine the heavy metal concentration of Cr, Mn, Fe, Cu and Pb in dissolved and total phases of the UCLR by means of Total Reflection X-ray Fluorescence Spectrometry (TXRF). The surface water samples were collected at 8 sites distributed following the stream flow direction of the river. Four sampling campaigns were carried out in each site in a 1-year period. A sample preparation method was applied in order to obtain the total and dissolved fraction and to destroy the organic matter. The total heavy metal average concentration decrease in the following order: Fe (2566 μg/L) > Mn (300 μg/L) > Cu (66 μg/L) > Cr (21 μg/L) > Pb (15 μg/L). In general, the heavy metal concentrations in water of the UCLR are below the maximum permissible limits

  6. Reflection Matrix Method for Controlling Light After Reflection From a Diffuse Scattering Surface

    Science.gov (United States)

    2016-12-22

    of Philosophy Kenneth W. Burgi, BS, MS Major, USAF 22 December 2016 DISTRIBUTION STATEMENT A APPROVED FOR PUBLIC RELEASE; DISTRIBUTION UNLIMITED. AFIT...refocusing light through thin films of a turbid medium. When coherent light is trans- mitted through a stationary diffuser (i.e. a turbid medium), a fine...resultant light scatter [14, 15, 21, 23]. Transmission matrices were measured with microscopic objectives and thin films of turbid media, resulting in

  7. Discrimination of the hard keratins animal horn and chelonian shell using attenuated total reflection-infrared spectroscopy.

    Science.gov (United States)

    Biscardi, Brianna; Welsh, Wendy; Kennedy, Anthony

    2012-05-01

    The ability to discriminate between objects manufactured from animal horn and chelonian (turtle, tortoise, or terrapin) shell is important from a cultural and archeological perspective such that it may allow conservators to determine the appropriate treatment and long-term care solution. It would also aid curators in identifying and cataloging items manufactured from these materials. Discrimination and classification is also a valuable tool for those involved in tracking the illegal trade in restricted materials of this nature. Attenuated total reflection infrared (ATR-IR) spectroscopy, using a single reflection diamond internal reflection element (IRE), coupled with discrimination analysis was used to analyze a total of thirty-nine samples (29 calibration samples, 10 validation samples). A discrimination analysis model was constructed using Mahalanobis distances to classify spectra into one of two classes. The model was then subsequently used to successfully classify all validation samples and correctly identify them as animal horn or chelonian shell based on second-derivative spectra of the amide I and II regions. This technique requires minimal to no sample preparation and may be used to nondestructively identify very small samples successfully without performing detailed secondary structural curve-fitting routines. This model should be a valuable resource to museums, conservators, and wildlife management programs for rapidly and reliably discriminating between animal horn and chelonian shell.

  8. Association Mapping of Total Carotenoids in Diverse Soybean Genotypes Based on Leaf Extracts and High-Throughput Canopy Spectral Reflectance Measurements.

    Directory of Open Access Journals (Sweden)

    Arun Prabhu Dhanapal

    Full Text Available Carotenoids are organic pigments that are produced predominantly by photosynthetic organisms and provide antioxidant activity to a wide variety of plants, animals, bacteria, and fungi. The carotenoid biosynthetic pathway is highly conserved in plants and occurs mostly in chromoplasts and chloroplasts. Leaf carotenoids play important photoprotective roles and targeted selection for leaf carotenoids may offer avenues to improve abiotic stress tolerance. A collection of 332 soybean [Glycine max (L. Merr.] genotypes was grown in two years and total leaf carotenoid content was determined using three different methods. The first method was based on extraction and spectrophotometric determination of carotenoid content (eCaro in leaf tissue, whereas the other two methods were derived from high-throughput canopy spectral reflectance measurements using wavelet transformed reflectance spectra (tCaro and a spectral reflectance index (iCaro. An association mapping approach was employed using 31,253 single nucleotide polymorphisms (SNPs to identify SNPs associated with total carotenoid content using a mixed linear model based on data from two growing seasons. A total of 28 SNPs showed a significant association with total carotenoid content in at least one of the three approaches. These 28 SNPs likely tagged 14 putative loci for carotenoid content. Six putative loci were identified using eCaro, five loci with tCaro, and nine loci with iCaro. Three of these putative loci were detected by all three carotenoid determination methods. All but four putative loci were located near a known carotenoid-related gene. These results showed that carotenoid markers can be identified in soybean using extract-based as well as by high-throughput canopy spectral reflectance-based approaches, demonstrating the utility of field-based canopy spectral reflectance phenotypes for association mapping.

  9. Deriving Light Interception and Biomass from Spectral Reflectance Ratio

    DEFF Research Database (Denmark)

    Christensen, Svend; Goudriaan, J.

    1993-01-01

    was calculated as the ratio between infrared (790–810 nm) and red (640–660 nm) reflectance. The cultivars form a different canopy structure. However, a regression analysis did not show any cultivar effect on the relation between RVI and fPAR The predicted fPAR from frequently measured RVI was used to calculate...... the product of daily fPAR and incoming PAR (cumulative PAR interception) in all spring barley cultivars grown in monoculture and in mixture with oil seed rape (Brassica napus). A regression analysis showed that the relation between cumulative intercepted PAR and total above ground biomass was the same in all...... monocultures and mixtures. The ratio α of incremental dry matter and intercepted PAR was normally 2.4 g MJ−1, but it declined below this value when temperatures fell below 12°C....

  10. Observation of neutron standing waves at total reflection by precision gamma spectroscopy

    International Nuclear Information System (INIS)

    Aksenov, V.L.; Gundorin, N.A.; Nikitenko, Yu.V.; Popov, Yu.P.; Cser, L.

    1998-01-01

    Total reflection of polarized neutrons from the layered structure glass/Fe (1000 A Angstrom)/Gd (50 A Angstrom) is investigated by registering neutrons and gamma-quanta from thermal neutron capture. The polarization ratio of gamma counts of neutron beams polarized in and opposite the direction of the magnetic field is measured. The polarization ratio is larger than unity for the neutron wavelengths λ 2.2 A Angstrom. Such behaviour of the wavelength dependence of the gamma-quanta polarization ratio points to the fact that over the surface of the Fe Layer a neutron standing wave caused by the interference of the incident neutron wave and the wave refracted from the magnetized Fe layer is formed

  11. Mix ratio measurements of pozzolanic blends by Fourier transform infrared-attenuated total reflectance method

    International Nuclear Information System (INIS)

    Rebagay, T.V.; Dodd, D.A.

    1992-07-01

    The disposal of low-level radioactive liquid wastes at the Hanford Site near Richland, Washington, involves mixing the wastes with pozzolanic grout-forming solid blends. Checking the quality of each blend component and its mix ratio will ensure processibility of the blend and the long-term performance of the resulting waste grout. In earlier work at Hanford laboratories, Fourier transform infrared-transmission method (FTIR-TR) using KBr pellet was applied successfully in the analysis of blends consisting of cement, fly ash, and clays. This method involves time-consuming sample preparation resulting in slow turnaround for repetitive sampling. Because reflection methods do not require elaborate sample preparation, they have the potential to reduce turnaround analysis time. Neat samples may be examined making these methods attractive for quality control. This study investigates the capability of Fourier transform infrared-attenuated total reflectance method (FTIR-ATR) to analyze pozzolanic blends

  12. Total reflection X-ray fluorescence and archaeometry: Application in the Argentinean cultural heritage

    Energy Technology Data Exchange (ETDEWEB)

    Vazquez, Cristina [Comision Nacional de Energia Atomica, Av. Gral Paz 1499 (B1650KNA) San Martin, Buenos Aires (Argentina); Laboratorio de Quimica de Sistemas Heterogeneos, Facultad de Ingenieria, Universidad de Buenos Aires, P. Colon 850 (C1063ACU), Buenos Aires (Argentina)], E-mail: Cristina.Vazquez@cnea.gov.ar; Albornoz, Ana [Agencia Rio Negro Cultura, Museo de la Patagonia F.P.Moreno, Centro Civico s/n Bariloche, Rio Negro (Argentina); Hajduk, Adam [CONICET, Museo de la Patagonia F.P.Moreno, Centro Civico s/n Bariloche, Rio Negro (Argentina); Elkin, Dolores [CONICET Instituto Nacional de Antropologia y Pensamiento Latinoamericano, 3 de febrero 1378 (C1426AEL) Buenos Aires (Argentina); Custo, Graciela; Obrustky, Alba [Comision Nacional de Energia Atomica, Av. Gral Paz 1499 (B1650KNA) San Martin, Buenos Aires (Argentina)

    2008-12-15

    Archaeometry is an interdisciplinary research area involved in the development and use of scientific methods in order to answer questions concerned with the human history. In this way the knowledge of archaeological objects through advanced chemical and physical analyses permits a better preservation and conservation of the cultural heritage and also reveals materials and technologies used in the past. In this sense, analytical techniques play an important role in order to provide chemical information about cultural objects. Considering the non destructive characteristic of this study, analytical techniques must be adequate in order to prevent any alteration or damage and in addition to allow the conservation of their integrity. Taking into account the irreplaceable character of the archaeological and artistic materials considered in this study, analytical techniques must be adequate in order to prevent any alteration or damage and in addition to allow the conservation of their integrity. Total Reflection X-ray Fluorescence Spectrometry as a geometric variant of conventional X-ray fluorescence is a proved microanalytical technique considering the small amount of sample required for the analysis. A few micrograms are enough in order to reveal valuable information about elemental composition and in this context it is highly recommended for artwork studies. In this paper a case study is presented in which Total Reflection X-Ray Fluorescence Spectrometry has been successfully employed in the archaeometry field. Examples from Argentinean cultural heritage sites related with the determination of pigments in paintings on canvas and in rock sites as well as in underwater archaeology research are shown.

  13. Light

    CERN Document Server

    Robertson, William C

    2003-01-01

    Why is left right and right left in the mirror? Baffled by the basics of reflection and refraction? Wondering just how the eye works? If you have trouble teaching concepts about light that you don t fully grasp yourself, get help from a book that s both scientifically accurate and entertaining with Light. By combining clear explanations, clever drawings, and activities that use easy-to-find materials, this book covers what science teachers and parents need to know to teach about light with confidence. It uses ray, wave, and particle models of light to explain the basics of reflection and refraction, optical instruments, polarization of light, and interference and diffraction. There s also an entire chapter on how the eye works. Each chapter ends with a Summary and Applications section that reinforces concepts with everyday examples. Whether you need a deeper understanding of how light bends or a good explanation of why the sky is blue, you ll find Light more illuminating and accessible than a college textbook...

  14. Angularly symmetric splitting of a light beam upon reflection and refraction at an air-dielectric plane boundary: comment.

    Science.gov (United States)

    Andersen, Torben B

    2016-05-01

    In a recent paper, conditions for achieving equal and opposite angular deflections of a light beam by reflection and refraction at an interface between air and a dielectric were determined [J. Opt. Soc. Am. A32, 2436 (2015)JOAOD60740-323210.1364/JOSAA.32.002436]. The paper gives plots of angles of incidence and refraction as a function of the prism refractive index as well as plots of reflectances and incident linear-polarization azimuth angles as functions of the refractive index. We show here that it is possible to express these quantities as simple algebraic functions of the refractive index.

  15. Synchrotron radiation total reflection X-ray fluorescence (SR-TXRF) for evaluation of food contamination

    International Nuclear Information System (INIS)

    Vives, A.E.S.; Brienza, S.M.B.; Moreira, S.; Zucchi, O.L.A.; Nascimento Filho, V.F.

    2006-01-01

    The objective of this study was to use synchrotron radiation total reflection X-ray fluorescence analysis (SR-TXRF) for the determination of metals and other elements in food available to the population in commercial establishments, in order to evaluate the risks of contamination by these products. The analyzed species were vegetables, leafy vegetables, fruits, cereal and grain. The results indicated that some species were contaminated by Cr, Cu, Zn and Pb with concentrations much higher than the reference values. (author)

  16. Nanograting-based plasmon enhancement for total internal reflection fluorescence microscopy of live cells

    International Nuclear Information System (INIS)

    Kim, Kyujung; Cho, Eun-Jin; Suh, Jin-Suck; Huh, Yong-Min; Kim, Donghyun; Kim, Dong Jun

    2009-01-01

    We investigated evanescent field enhancement based on subwavelength nanogratings for improved sensitivity in total internal reflection microscopy of live cells. The field enhancement is associated with subwavelength-grating-coupled plasmon excitation. An optimum sample employed a silver grating on a silver film and an SF10 glass substrate. Field intensity was enhanced by approximately 90% when measured by fluorescent excitation of microbeads relative to that on a bare prism as a control, which is in good agreement with numerical results. The subwavelength-grating-mediated field enhancement was also applied to live cell imaging of quantum dots, which confirmed the sensitivity enhancement qualitatively.

  17. Nonpolarizing beam splitter designed by frustrated total internal reflection inside a glass cube.

    Science.gov (United States)

    Xu, Xueke; Shao, Jianda; Fan, Zhengxiu

    2006-06-20

    A method for the design of an all-dielectric nonpolarizing prism beam splitter utilizing the principle of frustrated total internal reflection is reported. The nonpolarizing condition for a prism beam splitter is discussed, and some single layer design examples are elaborated. The concept can be applied to a wide range of wavelengths and arbitrary transmittance values, and with the help of a computer design program examples of 400-700 nm, T(p)=T(s)=0.5+/-0.01, with incident angles of 45 degrees and 62 degrees are given. In addition, the sensitivity and application of the design are also discussed.

  18. Secondary cell wall development in cotton fibers as examined with attenuated total reflection Fourier transform infrared spectroscopy

    Science.gov (United States)

    Cotton fibers harvested at 18, 20, 24, 28, 32, 36 and 40 days after flowering were examined using attenuated total reflection Fourier transform-infrared (ATR FT-IR) spectroscopy. The selected harvesting points coincide with secondary cell wall (SCW) development in the fibers. Progressive but moderat...

  19. Mechanisms for the reflection of light atoms from crystal surfaces at kilovolt energies

    International Nuclear Information System (INIS)

    Hou, M.; Robinson, M.T.

    1978-01-01

    The computer program MARLOWE was used to investigate the backscattering of protons from the (110) surface of a nickel crystal. Grazing incidence was considered so that anisotropic effects originated mainly from the surface region. The contribution of aligned scattering was studied by comparing the results with similar calculations for an amorphous target. Energy distributions of backscattered particles were investigated for incident energies ranging from 0.1 to 5 keV. The structure of these distributions was explained by making calculations for several target thickness. Specular reflection was found to depend on the structure of the first few atomic planes only. The (110) rows in the surface plane were responsible for focusing into surface semichannels. Focusing in these semichannels was found to be the strongest under total reflection conditions (below about 1.3 keV) while the scattering intensity from surface rows increased with increasing incident energy. The orientation of the plane of incidence was found to have large influence on the relative contributions of the reflection mechanisms involved. (orig.) [de

  20. Transmission and total reflection of subhertz electromagnetic waves at the earth-atmosphere interface

    International Nuclear Information System (INIS)

    Shiozawa, Toshiyuki

    2010-01-01

    For the purpose of providing for a theoretical background for the study of electromagnetic fields generated by precursory effects of earthquakes, the problem of transmission and total reflection at the earth-atmosphere interface is investigated in detail for a subhertz plane electromagnetic wave incident from the earth's crust. The term ''subhertz'' means 'below 1 Hz'. First, for the special case of normal incidence, the overall power transmission coefficient at the earth-atmosphere interface is found to take a maximum value at a definite frequency f 0 which is inversely proportional to the square of the depth of a virtual hypocenter. A typical value of f 0 falls around 0.01 Hz. For oblique incidence as well, this feature of the overall power transmission coefficient is retained except in the vicinity of the critical angle of incidence for the H-wave. At the critical angle of incidence, the power flow carried by a surface wave along the interface becomes anomalously large for the H-wave. However, over a wide range of angles of incidence greater than the critical angle, the power flow carried by the E-wave exceeds that carried by the H-wave by orders of magnitude. Finally, the energy conservation relations for the incident, reflected, and transmitted waves at the earth-atmosphere interface are discussed. For an incident wave coming from the earth's crust, the interactive power between the incident and reflected waves plays a crucial role for the conservation of energy at the interface.

  1. Optical interrupter based in the internal total reflection of spatial solitons at nonlinear saturable interfaces; Interruptores opticos basados en reflexion interna total de solitones espaciales en interfaces no lineales saturables

    Energy Technology Data Exchange (ETDEWEB)

    Alvarado-Mendez, E.; Torres-Cisneros, M.; Gutierrez-Hernandez, D. A.; Andrade-Lucio, J. A.; Rojas-Lagunas, R.; Pedraza-Ortega, J. C.; Torres Cisneros, G. E. [Universidad de Guanajuato, Guanajuato (Mexico); Sanchez Mondragon, J. J. [Universidad Autonoma del Estado de Morelos, Morelos (Mexico); Flores-Alvarado, G. [Preparatoria por Cooperacion Domingo Arenas, Tlaxcala (Mexico)

    2001-06-01

    We study the reflection of one-dimensional spatial soliton at the nonlinear interface between a saturable type medium and linear medium. Our study makes emphasis on determining the physical conditions under which the beam reflected by the interface is still a spatial soliton. Depended the incidence angle we find three critical regions for spatial solitons in the interface. We observed nonlinear Goos- Haechen shift is determined if reflection angle are conserved. Finally, we present preliminary experimental results in SBN61:Ce of the total internal reflection of one dimensional beam. [Spanish] Estudiamos la reflexion de un soliton espacial unidimensional en una interfase formada por un medio no lineal saturable y un medio lineal. Nuestros estudios hacen enfasis en determinar las condiciones fisicas bajo las cuales el haz reflejado por la interfase no lineal sigue siendo soliton. Encontramos tres regiones criticas para un soliton especial en la interfase, dependiendo del valor que tome el angulo de incidencia. Asi mismo observamos corrimiento Goos-Haechen no lineal que es determinante para la conservacion del angulo de reflexion. Finalmente, presentamos resultados preliminares experimentales en SBN61:Ce de la reflexion interna total de un haz unidimensional.

  2. Angularly symmetric splitting of a light beam upon reflection and refraction at an air-dielectric plane boundary.

    Science.gov (United States)

    Azzam, R M A

    2015-12-01

    Conditions for achieving equal and opposite angular deflections of a light beam by reflection and refraction at an air-dielectric boundary are determined. Such angularly symmetric beam splitting (ASBS) is possible only if the angle of incidence is >60° by exactly one third of the angle of refraction. This simple law, plus Snell's law, leads to several analytical results that clarify all aspects of this phenomenon. In particular, it is shown that the intensities of the two symmetrically deflected beams can be equalized by proper choice of the prism refractive index and the azimuth of incident linearly polarized light. ASBS enables a geometrically attractive layout of optical systems that employ multiple prism beam splitters.

  3. Single-Molecule Fluorescence Studies of Membrane Transporters Using Total Internal Reflection Microscopy.

    Science.gov (United States)

    Goudsmits, Joris M H; van Oijen, Antoine M; Slotboom, Dirk J

    2017-01-01

    Cells are delineated by a lipid bilayer that physically separates the inside from the outer environment. Most polar, charged, or large molecules require proteins to reduce the energetic barrier for passage across the membrane and to achieve transport rates that are relevant for life. Here, we describe techniques to visualize the functioning of membrane transport proteins with fluorescent probes at the single-molecule level. First, we explain how to produce membrane-reconstituted transporters with fluorescent labels. Next, we detail the construction of a microfluidic flow cell to image immobilized proteoliposomes on a total internal reflection fluorescence microscope. We conclude by describing the methods that are needed to analyze fluorescence movies and obtain useful single-molecule data. © 2017 Elsevier Inc. All rights reserved.

  4. The generalized vectorial laws of reflection and refraction

    International Nuclear Information System (INIS)

    Bhattacharjee, Pramode Ranjan

    2005-01-01

    This paper discloses two important discoveries. These are: (i) discovery of ambiguity in the well-established laws of reflection and refraction of light which have been in regular use for many years, and (ii) discovery of generalized vectorial laws of reflection and refraction of light. The existing definitions of angle of incidence, angle of reflection and angle of refraction are considered first. Each of these definitions is found to be ambiguous, not in compliance with the fundamental definition of angle in geometry. Two typical questions (one in the case of reflection and the other for refraction) have been addressed, which cannot be dealt with by using the existing laws of reflection and refraction of light. Thus, the existing laws of reflection and refraction of light seem to be ambiguous in respect of generality and their validity in a broad sense is questionable. With a view to removing the ambiguities, proper definitions of the above three angles are given first and then the statement of the generalized vectorial law of reflection (as well as that of refraction) has been offered

  5. Reflection and Non-Reflection of Particle Wavepackets

    Science.gov (United States)

    Cox, Timothy; Lekner, John

    2008-01-01

    Exact closed-form solutions of the time-dependent Schrodinger equation are obtained, describing the propagation of wavepackets in the neighbourhood of a potential. Examples given include zero reflection, total reflection and partial reflection of the wavepacket, for the sech[superscript 2]x/a, 1/x[superscript 2] and delta(x) potentials,…

  6. Light enhanced the accumulation of total fatty acids (TFA) and docosahexaenoic acid (DHA) in a newly isolated heterotrophic microalga Crypthecodinium sp. SUN.

    Science.gov (United States)

    Sun, Dongzhe; Zhang, Zhao; Mao, Xuemei; Wu, Tao; Jiang, Yue; Liu, Jin; Chen, Feng

    2017-03-01

    In the present study, light illumination was found to be efficient in elevating the total fatty acid content in a newly isolated heterotrophic microalga, Crypthecodinium sp. SUN. Under light illumination, the highest total fatty acid and DHA contents were achieved at 96h as 24.9% of dry weight and 82.8mgg -1 dry weight, respectively, which were equivalent to 1.46-fold and 1.68-fold of those under the dark conditions. The elevation of total fatty acid content was mainly contributed by an increase of neutral lipids at the expense of starches. Moreover, light was found to alter the cell metabolism and led to a higher specific growth rate, higher glucose consumption rate and lower non-motile cell percentage. This is the first report that light can promote the total fatty acids accumulation in Crypthecodinium without growth inhibition. Copyright © 2016 Elsevier Ltd. All rights reserved.

  7. The capabilities of total reflection X-ray fluorescence in the polymeric analytical field

    International Nuclear Information System (INIS)

    Vazquez, Cristina

    2004-01-01

    This paper presents the capabilities of total reflection X-ray fluorescence (TXRF) as analytical technique specially focused in high-viscosity polymer dispersions. Appropriate sample preparation procedures are described taking into account the time stability of these dispersions. Special remarks considering different ways for drying samples in order to obtain the most uniform deposited film are investigated focusing on the behavior of aqueous and viscous systems. Due to the difficulty found for obtaining a homogeneous mixture between sample and internal standard in such systems, the use of Compton incoherent scattering is discussed as an alternative procedure for trace quantification in high viscous systems without any mixing processes

  8. Single cell adhesion strength assessed with variable-angle total internal reflection fluorescence microscopy

    Directory of Open Access Journals (Sweden)

    Marcelina Cardoso Dos Santos

    2017-06-01

    Full Text Available We propose a new strategy to evaluate adhesion strength at the single cell level. This approach involves variable-angle total internal reflection fluorescence microscopy to monitor in real time the topography of cell membranes, i.e. a map of the membrane/substrate separation distance. According to the Boltzmann distribution, both potential energy profile and dissociation energy related to the interactions between the cell membrane and the substrate were determined from the membrane topography. We have highlighted on glass substrates coated with poly-L-lysine and fibronectin, that the dissociation energy is a reliable parameter to quantify the adhesion strength of MDA-MB-231 motile cells.

  9. Determination of heavy metals in Damascus drinking water using total reflection x-ray fluorescence

    International Nuclear Information System (INIS)

    Bakraji, E. H.; Karajo, J.

    2000-01-01

    Total reflection x-ray fluorescence spectrometry and chemical preconcentration have applied for multi-elemental analysis of Damascus drinking water. Water was taken directly from taps of several city sectors and analyzed for the following trace elements: Ti, V, Cr, Fe, Co, Ni, Cu, Zn, Se and Pb. The detection limits were found to be in the range of 0.1 to 0.4 μg/l. The mean levels of trace elements in the Damascus drinking water were below the World Health Organization drinking water quality guidelines. (author)

  10. Synchrotron total reflection X-ray fluorescence at BL-16 microfocus beamline of Indus-2

    Energy Technology Data Exchange (ETDEWEB)

    Tiwari, M. K., E-mail: mktiwari@rrcat.gov.in; Singh, A. K., E-mail: mktiwari@rrcat.gov.in; Das, Gangadhar, E-mail: mktiwari@rrcat.gov.in; Chowdhury, Anupam, E-mail: mktiwari@rrcat.gov.in; Lodha, G. S., E-mail: mktiwari@rrcat.gov.in [Indus Synchrotrons Utilisation Division, Raja Ramanna Centre for Advanced Technology, Indore-452013 (India)

    2014-04-24

    Determination of ultra trace elements is important in many disciplines both in basic and applied sciences. Numerous applications show their importance in medical science, environmental science, materials science, food processing and semiconductor industries and in maintaining the quality control of ultra pure chemicals and reagents. We report commissioning of a synchrotron based total reflection x-ray fluorescence (TXRF) facility on the BL-16 microfocus beamline of Indus-2. This paper describes the performance of the BL-16 TXRF spectrometer and the detailed description of its capabilities through examples of measured results.

  11. On revealing the vertical structure of nanoparticle films with elemental resolution: A total external reflection X-ray standing waves study

    Energy Technology Data Exchange (ETDEWEB)

    Zargham, Ardalan, E-mail: zargham@ifp.uni-bremen.d [Institute of Solid State Physics, University of Bremen, Otto-Hahn-Allee 1, 28359 Bremen (Germany); Schmidt, Thomas; Flege, Jan Ingo; Sauerbrey, Marc; Hildebrand, Radowan [Institute of Solid State Physics, University of Bremen, Otto-Hahn-Allee 1, 28359 Bremen (Germany); Roehe, Sarah; Baeumer, Marcus [Applied and Physical Chemistry, University of Bremen, Leobener Str. 2, 28359, Bremen (Germany); Falta, Jens [Institute of Solid State Physics, University of Bremen, Otto-Hahn-Allee 1, 28359 Bremen (Germany)

    2010-02-15

    We present a promising combination of methods to precisely determine the morphology of nanostructures, drawing on the example of monodisperse CoPt{sub 3} nanoparticle films deposited by spin coating and dip coating techniques on functionalized Au substrates. Ex-situ X-ray standing waves in total external reflection combined with X-ray reflectivity measurements were employed to determine element-specific atomic-density distributions in vertical direction.

  12. Influence of the linear magneto-electric effect on the lateral shift of light reflected from a magneto-electric film

    International Nuclear Information System (INIS)

    Dadoenkova, Yu S; Petrov, R V; Bichurin, M I; Bentivegna, F F L; Dadoenkova, N N; Lyubchanskii, I L

    2016-01-01

    We present a theoretical investigation of the lateral shift of an infrared light beam reflected from a magnetic film deposited on a non-magnetic dielectric substrate, taking into account the linear magneto-electric interaction in the magnetic film. We use the stationary phase method to evaluate the lateral shift. It is shown that the magneto-electric coupling leads to a six-fold enhancement of the lateral shift amplitude of a p-(s-) polarized incident beam reflected into a s-(p-) polarized beam. A reversal of the magnetization in the film leads to a nonreciprocal sign change of the lateral shift. (paper)

  13. Recent trends in total reflection X-ray fluorescence spectrometry for biological applications

    International Nuclear Information System (INIS)

    Szoboszlai, Norbert; Polgari, Zsofia; Mihucz, Victor G.; Zaray, Gyula

    2009-01-01

    This review is focused on the application of total reflection X-ray fluorescence (TXRF) spectrometry in the field of biological research. In the last decade, most papers were published by authors who applied laboratory-scale TXRF equipments. The application of synchrotron radiation as excitation source (SR-TXRF) shows a slowly increasing tendency. In the cited papers the micro-, trace and multielement capability of these TXRF techniques was demonstrated in the clinical and medical laboratory practice, as well as in various plant physiological studies. For speciation of elements in biological matrices, the TXRF was used as element specific detector following an off-line separation step (e.g., thin layer chromatography, high performance liquid chromatography), however, these off-line methods are not competitive with the on-line coupled HPLC-inductively coupled plasma mass spectrometry

  14. Thin film characterization by total reflection x-ray fluorescence

    International Nuclear Information System (INIS)

    Danel, Adrien; Nolot, Emmanuel; Veillerot, Marc; Olivier, Segolene; Decorps, Tifenn; Calvo-Munoz, Maria-Luisa; Hartmann, Jean-Michel; Lhostis, Sandrine; Kohno, Hiroshi; Yamagami, Motoyuki; Geoffroy, Charles

    2008-01-01

    Sensitive and accurate characterization of films thinner than a few nm used in nanoelectronics represents a challenge for many conventional production metrology tools. With capabilities in the 10 10 at/cm 2 , methods usually dedicated to contamination analysis appear promising, especially Total-reflection X-Ray Fluorescence (TXRF). This study shows that under usual configuration for contamination analysis, with incident angle smaller than the critical angle of the substrate, TXRF signal saturation occurs very rapidly for dense films (below 0.5 nm for HfO 2 films on Si wafers using a 9.67 keV excitation at 0.5 deg.). Increasing the incident angle, the range of linear results can be extended, but on the other hand, the TXRF sensitivity is degraded because of a strong increase of the measurement dead time. On HfO 2 films grown on Si wafers, an incident angle of 0.32 deg. corresponding to a dead time of 95% was used to achieve linear analysis up to 2 nm. Composition analysis by TXRF, and especially the detection of minor elements into thin films, requires the use of a specific incident angle to optimize sensitivity. Although quantitative analyses might require specific calibration, this work shows on Co-based films that the ratio between minor elements (W, P, Mo) and Co taking into account their relative sensitivity factors is a good direct reading of the composition

  15. Out-of-plane reflection and refraction of light by anisotropic optical antenna metasurfaces with phase discontinuities.

    Science.gov (United States)

    Aieta, Francesco; Genevet, Patrice; Yu, Nanfang; Kats, Mikhail A; Gaburro, Zeno; Capasso, Federico

    2012-03-14

    Experiments on ultrathin anisotropic arrays of subwavelength optical antennas display out-of-plane refraction. A powerful three-dimensional (3D) extension of the recently demonstrated generalized laws of refraction and reflection shows that the interface imparts a tangential wavevector to the incident light leading to anomalous beams, which in general are noncoplanar with the incident beam. The refracted beam direction can be controlled by varying the angle between the plane of incidence and the antenna array. © 2012 American Chemical Society

  16. Attenuated total internal reflection infrared microspectroscopic imaging using a large-radius germanium internal reflection element and a linear array detector.

    Science.gov (United States)

    Patterson, Brian M; Havrilla, George J

    2006-11-01

    The number of techniques and instruments available for Fourier transform infrared (FT-IR) microspectroscopic imaging has grown significantly over the past few years. Attenuated total internal reflectance (ATR) FT-IR microspectroscopy reduces sample preparation time and has simplified the analysis of many difficult samples. FT-IR imaging has become a powerful analytical tool using either a focal plane array or a linear array detector, especially when coupled with a chemometric analysis package. The field of view of the ATR-IR microspectroscopic imaging area can be greatly increased from 300 x 300 microm to 2500 x 2500 microm using a larger internal reflection element of 12.5 mm radius instead of the typical 1.5 mm radius. This gives an area increase of 70x before aberrant effects become too great. Parameters evaluated include the change in penetration depth as a function of beam displacement, measurements of the active area, magnification factor, and change in spatial resolution over the imaging area. Drawbacks such as large file size will also be discussed. This technique has been successfully applied to the FT-IR imaging of polydimethylsiloxane foam cross-sections, latent human fingerprints, and a model inorganic mixture, which demonstrates the usefulness of the method for pharmaceuticals.

  17. Study of a total reflection Cerenkov counter

    International Nuclear Information System (INIS)

    Didelez, J.P.

    1979-01-01

    A Monte Carlo program simulates the emission and collection of Cerenkov light due to P and π (0.6 to 1.4 GeV/c) going through a rectangular parallelepiped of plexiglas. Without taking into account the knocked out electrons (delta) a good theoretical separation is obtained between P and π. The contribution of delta electrons has been calculated separately. Experimental tests are under way using cosmic rays [fr

  18. Signal-enhancement reflective pulse oximeter with Fresnel lens

    Science.gov (United States)

    Chung, Shuang-Chao; Sun, Ching-Cherng

    2016-09-01

    In this paper, a new reflective pulse oximeter is proposed and demonstrated with implanting a Fresnel lens, which enhances the reflected signal. An optical simulation model incorporated with human skin characteristics is presented to evaluate the capability of the Fresnel lens. In addition, the distance between the light emitting diode and the photodiode is optimized. Compared with the other reflective oximeters, the reflected signal light detected by the photodiode is enhanced to more than 140%.

  19. Deep Learning-Based Banknote Fitness Classification Using the Reflection Images by a Visible-Light One-Dimensional Line Image Sensor

    Directory of Open Access Journals (Sweden)

    Tuyen Danh Pham

    2018-02-01

    Full Text Available In automatic paper currency sorting, fitness classification is a technique that assesses the quality of banknotes to determine whether a banknote is suitable for recirculation or should be replaced. Studies on using visible-light reflection images of banknotes for evaluating their usability have been reported. However, most of them were conducted under the assumption that the denomination and input direction of the banknote are predetermined. In other words, a pre-classification of the type of input banknote is required. To address this problem, we proposed a deep learning-based fitness-classification method that recognizes the fitness level of a banknote regardless of the denomination and input direction of the banknote to the system, using the reflection images of banknotes by visible-light one-dimensional line image sensor and a convolutional neural network (CNN. Experimental results on the banknote image databases of the Korean won (KRW and the Indian rupee (INR with three fitness levels, and the Unites States dollar (USD with two fitness levels, showed that our method gives better classification accuracy than other methods.

  20. Deep Learning-Based Banknote Fitness Classification Using the Reflection Images by a Visible-Light One-Dimensional Line Image Sensor.

    Science.gov (United States)

    Pham, Tuyen Danh; Nguyen, Dat Tien; Kim, Wan; Park, Sung Ho; Park, Kang Ryoung

    2018-02-06

    In automatic paper currency sorting, fitness classification is a technique that assesses the quality of banknotes to determine whether a banknote is suitable for recirculation or should be replaced. Studies on using visible-light reflection images of banknotes for evaluating their usability have been reported. However, most of them were conducted under the assumption that the denomination and input direction of the banknote are predetermined. In other words, a pre-classification of the type of input banknote is required. To address this problem, we proposed a deep learning-based fitness-classification method that recognizes the fitness level of a banknote regardless of the denomination and input direction of the banknote to the system, using the reflection images of banknotes by visible-light one-dimensional line image sensor and a convolutional neural network (CNN). Experimental results on the banknote image databases of the Korean won (KRW) and the Indian rupee (INR) with three fitness levels, and the Unites States dollar (USD) with two fitness levels, showed that our method gives better classification accuracy than other methods.

  1. Method of Determining Reflections of Light

    DEFF Research Database (Denmark)

    2017-01-01

    A method of filtering glints by processing an image of a user's cornea to obtain coordinates of desired glints from a configuration of light sources, comprising processing an image, in a first image space, of a user's cornea to determine coordinates of respective multiple positions of glints...

  2. Widefield and total internal reflection fluorescent structured illumination microscopy with scanning galvo mirrors

    Science.gov (United States)

    Chen, Youhua; Cao, Ruizhi; Liu, Wenjie; Zhu, Dazhao; Zhang, Zhiming; Kuang, Cuifang; Liu, Xu

    2018-04-01

    We present an alternative approach to realize structured illumination microscopy (SIM), which is capable for live cell imaging. The prototype utilizes two sets of scanning galvo mirrors, a polarization converter and a piezo-platform to generate a fast shifted, s-polarization interfered and periodic variable illumination patterns. By changing the angle of the scanning galvanometer, we can change the position of the spots at the pupil plane of the objective lens arbitrarily, making it easy to switch between widefield and total internal reflection fluorescent-SIM mode and adapting the penetration depth in the sample. Also, a twofold resolution improvement is achieved in our experiments. The prototype offers more flexibility of pattern period and illumination orientation changing than previous systems.

  3. Using Light-Induced Thermocleavage in a Roll-to-Roll Process for Polymer Solar Cells

    DEFF Research Database (Denmark)

    Krebs, Frederik C; Norrman, Kion

    2010-01-01

    We report on the use of intense visible light with a narrow spectral distribution matched to the region where the conjugated polymer material absorbs to selectively heat the active material and induce thermocleavage. We show a full roll-to-roll process, leading to complete large-area polymer solar...... ion mass spectrometry, attenuated total reflectance infrared, and transmission/reflection UV−vis techniques....

  4. Specific features of diffuse reflection of human face skin for laser and non-laser sources of visible and near-IR light

    International Nuclear Information System (INIS)

    Dolotov, L E; Sinichkin, Yu P; Tuchin, Valerii V; Al'tshuler, G B; Yaroslavskii, I V

    2011-01-01

    The specific features of diffuse reflection from different areas of human face skin for laser and non-laser sources of visible and near-IR light have been investigated to localise the closed-eye (eyelid) region. In the visible spectral range the reflection from the eyelid skin surface can be differentiated by measuring the slope of the spectral dependence of the effective optical density of skin in the wavelength range from 650 to 700nm. In the near-IR spectral range the reflectances of the skin surface at certain wavelengths, normalised to the forehead skin reflectance, can be used as a criterion for differentiating the eyelid skin. In this case, a maximum discrimination is obtained when measuring the skin reflectances at laser wavelengths of 1310 and 1470nm, which correspond to the spectral ranges of maximum and minimum water absorption. (optical technologies in biophysics and medicine)

  5. Reflection technique for thermal mapping of semiconductors

    Science.gov (United States)

    Walter, Martin J.

    1989-06-20

    Semiconductors may be optically tested for their temperatures by illuminating them with tunable monochromatic electromagnetic radiation and observing the light reflected off of them. A transition point will occur when the wavelength of the light corresponds with the actual band gap energy of the semiconductor. At the transition point, the image of the semiconductor will appreciably darken as the light is transmitted through it, rather than being reflected off of it. The wavelength of the light at the transition point corresponds to the actual band gap energy and the actual temperature of the semiconductor.

  6. Reflection measurements for luminescent powders

    Science.gov (United States)

    Kroon, R. E.

    2018-04-01

    Luminescent materials are useful in applications varying from lighting and display technologies to document security features and medical research, amongst many others. Measurement of the excitation range is an important consideration, and absorption bands are often determined from a decrease in the measured diffuse reflectance of the material using a ultraviolet-visible (UV-vis) spectrophotometer with an integrating sphere. Such a system may provide questionable results when used to measure the reflectance of a luminescence material, which is demonstrated for a Tb doped silica phosphor, because the system cannot differentiate between the reflected light and luminescence. It is shown that more reliable results are achieved for this phosphor by measuring the reflectance using a synchronous zero-offset scan in a fluorescence spectrometer equipped with an integrating sphere. This method is therefore recommended instead of traditional reflectance measurements using a UV-vis spectrophotometer for luminescent powders.

  7. Recognition of Banknote Fitness Based on a Fuzzy System Using Visible Light Reflection and Near-infrared Light Transmission Images.

    Science.gov (United States)

    Kwon, Seung Yong; Pham, Tuyen Danh; Park, Kang Ryoung; Jeong, Dae Sik; Yoon, Sungsoo

    2016-06-11

    Fitness classification is a technique to assess the quality of banknotes in order to determine whether they are usable. Banknote classification techniques are useful in preventing problems that arise from the circulation of substandard banknotes (such as recognition failures, or bill jams in automated teller machines (ATMs) or bank counting machines). By and large, fitness classification continues to be carried out by humans, and this can cause the problem of varying fitness classifications for the same bill by different evaluators, and requires a lot of time. To address these problems, this study proposes a fuzzy system-based method that can reduce the processing time needed for fitness classification, and can determine the fitness of banknotes through an objective, systematic method rather than subjective judgment. Our algorithm was an implementation to actual banknote counting machine. Based on the results of tests on 3856 banknotes in United States currency (USD), 3956 in Korean currency (KRW), and 2300 banknotes in Indian currency (INR) using visible light reflection (VR) and near-infrared light transmission (NIRT) imaging, the proposed method was found to yield higher accuracy than prevalent banknote fitness classification methods. Moreover, it was confirmed that the proposed algorithm can operate in real time, not only in a normal PC environment, but also in an embedded system environment of a banknote counting machine.

  8. Recognition of Banknote Fitness Based on a Fuzzy System Using Visible Light Reflection and Near-infrared Light Transmission Images

    Directory of Open Access Journals (Sweden)

    Seung Yong Kwon

    2016-06-01

    Full Text Available Fitness classification is a technique to assess the quality of banknotes in order to determine whether they are usable. Banknote classification techniques are useful in preventing problems that arise from the circulation of substandard banknotes (such as recognition failures, or bill jams in automated teller machines (ATMs or bank counting machines. By and large, fitness classification continues to be carried out by humans, and this can cause the problem of varying fitness classifications for the same bill by different evaluators, and requires a lot of time. To address these problems, this study proposes a fuzzy system-based method that can reduce the processing time needed for fitness classification, and can determine the fitness of banknotes through an objective, systematic method rather than subjective judgment. Our algorithm was an implementation to actual banknote counting machine. Based on the results of tests on 3856 banknotes in United States currency (USD, 3956 in Korean currency (KRW, and 2300 banknotes in Indian currency (INR using visible light reflection (VR and near-infrared light transmission (NIRT imaging, the proposed method was found to yield higher accuracy than prevalent banknote fitness classification methods. Moreover, it was confirmed that the proposed algorithm can operate in real time, not only in a normal PC environment, but also in an embedded system environment of a banknote counting machine.

  9. Guiding light by and beyond the total internal reflection mechanism

    NARCIS (Netherlands)

    Uranus, H.P.

    2005-01-01

    Photonics plays an important role in modern technologies, e.g. in telecommunications and sensing systems. Waveguiding structures with micro- and nano-meter scale features are the basic building blocks of photonic circuits. Large varieties of structures have been used by scientists and engineers.

  10. Reflected Light from Giant Planets in Habitable Zones: Tapping into the Power of the Cross-Correlation Function.

    Science.gov (United States)

    Martins, J H C; Santos, N C; Figueira, P; Melo, C

    2016-11-01

    The direct detection of reflected light from exoplanets is an excellent probe for the characterization of their atmospheres. The greatest challenge for this task is the low planet-to-star flux ratio, which even in the most favourable case is of the order of 10 -4 in the optical. This ratio decreases even more for planets in their host's habitable zone, typically lower than 10 -7 . To reach the signal-to-noise level required for such detections, we propose to unleash the power of the Cross Correlation Function in combination with the collecting power of next generation observing facilities. The technique we propose has already yielded positive results by detecting the reflected spectral signature of 51 Pegasi b (see Martins et al. 2015). In this work, we attempted to infer the number of hours required for the detection of several planets in their host's habitable zone using the aforementioned technique from theoretical EELT observations. Our results show that for 5 of the selected planets it should be possible to directly recover their reflected spectral signature.

  11. Wide angle light collection with ultralow reflection and super scattering by silicon micro-nanostructures for thin crystalline silicon solar cell applications

    International Nuclear Information System (INIS)

    Das, Sonali; Kundu, Avra; Saha, Hiranmay; Datta, Swapan K

    2016-01-01

    Conventional c-Si solar cells employ micron-sized pyramids for achieving reduced reflection (∼10%) and enhanced light trapping by multiple bounces (maximum 3) of the incident light. Alternatively, bio-mimetic, moth-eye sub-wavelength nanostructures offer broadband antireflection properties (∼3%) suitable for solar cell applications in the optical regime. However, such structures do not provide any advantage in the charge carrier extraction process as radial junctions cannot be formed in such sub-wavelength dimensions and they have high surface area causing increased charged carrier recombination. The choice of the geometry for achieving optimum photon–electron harvesting for solar applications is therefore very critical. Cross-fertilization of the conventional solar cell light-trapping techniques and the sub-wavelength nanostructures results in unique micro-nanostructures (structures having sub-wavelength dimensions as well as dimensions of the order of few microns) which provide advanced light management capabilities along with the ability of realizing radial junctions. It is seen that an ultralow reflection along with wide angle light collection is obtained which enables such structures to overcome the morning, evening and winter light losses in solar cells. Further, super-scattering in the structures offer enhanced light trapping not only in the structure itself but also in the substrate housing the structure. Ray and wave optics have been used to understand the optical benefits of the structures. It is seen that the aspect ratio of the structures plays the most significant role for achieving such light management capabilities, and efficiencies as high as 12% can be attained. Experiments have been carried out to fabricate a unique micro-nanomaze-like structure instead of a periodic array of micro-nanostructures with the help of nanosphere lithography and the MacEtch technique. It is seen that randomized micro-nanomaze geometry offers very good

  12. High-Reflectivity Multi-Layer Coatings for the CLASP Sounding Rocket Project

    Science.gov (United States)

    Narukage, Noriyuki; Kano, Ryohei; Bando, Takamasa; Ishikawa, Ryoko; Kubo, Masahito; Katsukawa, Yukio; Ishikawa, Shin-nosuke; Kobiki, Toshihiko; Giono, Gabriel; Auchere, Frederic; hide

    2015-01-01

    We are planning an international rocket experiment Chromospheric Lyman-Alpha Spectro-Polarimeter (CLASP) is (2015 planned) that Lyman alpha line (Ly alpha line) polarization spectroscopic observations from the sun. The purpose of this experiment, detected with high accuracy of the linear polarization of the Ly alpha lines to 0.1% by using a Hanle effect is to measure the magnetic field of the chromosphere-transition layer directly. For polarization photometric accuracy achieved that approximately 0.1% required for CLASP, it is necessary to realize the monitoring device with a high throughput. On the other hand, Ly alpha line (vacuum ultraviolet rays) have a sensitive characteristics that is absorbed by the material. We therefore set the optical system of the reflection system (transmission only the wavelength plate), each of the mirrors, subjected to high efficiency of the multilayer coating in accordance with the role. Primary mirror diameter of CLASP is about 30 cm, the amount of heat about 30,000 J is about 5 minutes of observation time is coming mainly in the visible light to the telescope. In addition, total flux of the sun visible light overwhelmingly large and about 200 000 times the Ly alpha line wavelength region. Therefore, in terms of thermal management and 0.1% of the photometric measurement accuracy achieved telescope, elimination of the visible light is essential. We therefore, has a high reflectivity (greater than 50%) in Ly alpha line, visible light is a multilayer coating be kept to a low reflectance (less than 5%) (cold mirror coating) was applied to the primary mirror. On the other hand, the efficiency of the polarization analyzer required chromospheric magnetic field measurement (the amount of light) Conventional (magnesium fluoride has long been known as a material for vacuum ultraviolet (MgF2) manufactured ellipsometer; Rs = 22%) about increased to 2.5 times were high efficiency reflective polarizing element analysis. This device, Bridou et al

  13. Waves and grains reflections on light and learning

    CERN Document Server

    Silverman, Mark P

    1998-01-01

    Mark Silverman has seen light perform many wonders. From the marvel of seeing inside cloudy liquids as a result of his own cutting-edge research to reproducing and examining an unusual diffraction pattern first witnessed by Isaac Newton 300 years ago, he has studied aspects of light that have inspired and puzzled humans for hundreds of years. In this book, he draws on his many experiences as an optical and atomic physicist--and on his consummate skills as a teacher and writer about the mysteries of physics--to present a remarkable tour of the world of light. He explores theoretical, experimental, and historical themes, showing a keen eye for curious and neglected corners of the study of light and a fascination with the human side of scientific discovery. In the course of the book, he covers such questions as how it is possible to achieve magnifications of a millionfold without a single lens or mirror. He asks what all living things have in common that might one day allow the development of a "life-form scann...

  14. Interference of conically scattered light in surface plasmon resonance.

    Science.gov (United States)

    Webster, Aaron; Vollmer, Frank

    2013-02-01

    Surface plasmon polaritons on thin metal films are a well studied phenomena when excited using prism coupled geometries such as the Kretschmann attenuated total reflection configuration. Here we describe a novel interference pattern in the conically scattered light emanating from such a configuration when illuminated by a focused beam. We observe conditions indicating only self-interference of scattered surface plasmon polaritions without any contributions from specular reflection. The spatial evolution of this field is described in the context of Fourier optics and has applications in highly sensitive surface plasmon based biosensing.

  15. An assessment of the stray light in 25 years of Dobson total ozone data at Athens, Greece

    Science.gov (United States)

    Christodoulakis, J.; Varotsos, C.; Cracknell, A. P.; Tzanis, C.; Neofytos, A.

    2015-07-01

    In this study, we investigated the susceptibility of the Dobson spectrophotometer No. 118 to stray light interference. In this regard, a series of total ozone content measurements were carried out in Athens, Greece for air-mass values (μ) extending up to μ = 5. The monochromatic-heterochromatic stray light derived by Basher's model was used in order to evaluate the specific instrumental parameters which determine if this instrument suffers from this problem or not. The results obtained indicate that the measurements made by the Dobson instrument of the Athens station for air mass values up to 2.5, underestimates the total ozone content by 3.5 DU in average, or about 1 % of the station's mean total ozone content (TOC). The comparison of the values of the same parameters measured 15 years ago with the present ones indicates the good maintenance of the Dobson spectrophotometer No. 118. This fact is of crucial importance because the variability of the daily total ozone observations collected by the Athens Dobson Station since 1989 has proved to be representative to the variability of the mean total ozone observed over the whole mid-latitude zone of the Northern Hemisphere. This stresses the point that the Athens total ozone station, being the unique Dobson station in south-eastern Europe, may be assumed as a ground truth station for the reliable conversion of the satellite radiance observations to total ozone measurements.

  16. Determination of lead in clay enameled by X-ray fluorescence technique in Total reflection and by Scanning Electron Microscopy

    International Nuclear Information System (INIS)

    Zarazua O, G.; Carapia M, L.

    2000-01-01

    This work has the objective of determining lead free in the glazed commercial stewing pans using the X-ray fluorescence technique in Total reflection (FRX) and the observation and semiquantitative determination of lead by Analytical Scanning Electron Microscopy (ASEM). (Author)

  17. Parameter study of self-absorption effects in Total Reflection X-ray Fluorescence-X-ray Absorption Near Edge Structure analysis of arsenic

    International Nuclear Information System (INIS)

    Meirer, F.; Pepponi, G.; Streli, C.; Wobrauschek, P.; Kregsamer, P.; Zoeger, N.; Falkenberg, G.

    2008-01-01

    Total reflection X-ray Fluorescence (TXRF) analysis in combination with X-ray Absorption Near Edge Structure (XANES) analysis is a powerful method to perform chemical speciation studies at trace element levels. However, when measuring samples with higher concentrations and in particular standards, damping of the oscillations is observed. In this study the influence of self-absorption effects on TXRF-XANES measurements was investigated by comparing measurements with theoretical calculations. As(V) standard solutions were prepared at various concentrations and dried on flat substrates. The measurements showed a correlation between the damping of the oscillations and the As mass deposited. A Monte-Carlo simulation was developed using data of the samples shapes obtained from confocal white light microscopy. The results showed good agreement with the measurements; they confirmed that the key parameters are the density of the investigated atom in the dried residues and the shape of the residue, parameters that combined define the total mass crossed by a certain portion of the incident beam. The study presents a simple approach for an a priori evaluation of the self-absorption in TXRF X-ray absorption studies. The consequences for Extended X-ray Absorption Fine Structure (EXAFS) and XANES measurements under grazing incidence conditions are discussed, leading to the conclusion that the damping of the oscillations seems to make EXAFS of concentrated samples non feasible. For XANES 'fingerprint' analysis samples should be prepared with a deposited mass and sample shape leading to an acceptable absorption for the actual investigation

  18. Reflected Glory

    Science.gov (United States)

    2011-02-01

    HD 38563B, are the main powerhouses behind Messier 78. However, the nebula is home to many more stars, including a collection of about 45 low mass, young stars (less than 10 million years old) in which the cores are still too cool for hydrogen fusion to start, known as T Tauri stars. Studying T Tauri stars is important for understanding the early stages of star formation and how planetary systems are created. Remarkably, this complex of nebulae has also changed significantly in the last ten years. In February 2004 the experienced amateur observer Jay McNeil took an image of this region with a 75 mm telescope and was surprised to see a bright nebula - the prominent fan shaped feature near the bottom of this picture - where nothing was seen on most earlier images. This object is now known as McNeil's Nebula and it appears to be a highly variable reflection nebula around a young star. This colour picture was created from many monochrome exposures taken through blue, yellow/green and red filters, supplemented by exposures through an H-alpha filter that shows light from glowing hydrogen gas. The total exposure times were 9, 9, 17.5 and 15.5 minutes per filter, respectively. Notes [1] Igor Chekalin from Russia uncovered the raw data for this image of Messier 78 in ESO's archives in the competition Hidden Treasures (eso1102). He processed the raw data with great skill, claiming first prize in the contest for his final image (Flickr link). ESO's team of in-house image processing experts then independently processed the raw data at full resolution to produce the image shown here. More information ESO, the European Southern Observatory, is the foremost intergovernmental astronomy organisation in Europe and the world's most productive astronomical observatory. It is supported by 15 countries: Austria, Belgium, Brazil, the Czech Republic, Denmark, France, Finland, Germany, Italy, the Netherlands, Portugal, Spain, Sweden, Switzerland and the United Kingdom. ESO carries out an

  19. Hewlett-Packard's Approaches to Full Color Reflective Displays

    Science.gov (United States)

    Gibson, Gary

    2012-02-01

    Reflective displays are desirable in applications requiring low power or daylight readability. However, commercial reflective displays are currently either monochrome or capable of only dim color gamuts. Low cost, high-quality color technology would be rapidly adopted in existing reflective display markets and would enable new solutions in areas such as retail pricing and outdoor digital signage. Technical breakthroughs are required to enable bright color gamuts at reasonable cost. Pixel architectures that rely on pure reflection from a single layer of side-by-side primary-color sub-pixels use only a fraction of the display area to reflect incident light of a given color and are, therefore, unacceptably dark. Reflective devices employing stacked color primaries offer the possibility of a somewhat brighter color gamut but can be more complex to manufacture. In this talk, we describe HP's successes in addressing these fundamental challenges and creating both high performance stacked-primary reflective color displays as well as inexpensive single layer prototypes that provide good color. Our stacked displays utilize a combination of careful light management techniques, proprietary high-contrast electro-optic shutters, and highly transparent active-matrix TFT arrays based on transparent metal oxides. They also offer the possibility of relatively low cost manufacturing through roll-to-roll processing on plastic webs. To create even lower cost color displays with acceptable brightness, we have developed means for utilizing photoluminescence to make more efficient use of ambient light in a single layer device. Existing reflective displays create a desired color by reflecting a portion of the incident spectrum while absorbing undesired wavelengths. We have developed methods for converting the otherwise-wasted absorbed light to desired wavelengths via tailored photoluminescent composites. Here we describe a single active layer prototype display that utilizes these materials

  20. From Intensity Profile to Surface Normal: Photometric Stereo for Unknown Light Sources and Isotropic Reflectances.

    Science.gov (United States)

    Lu, Feng; Matsushita, Yasuyuki; Sato, Imari; Okabe, Takahiro; Sato, Yoichi

    2015-10-01

    We propose an uncalibrated photometric stereo method that works with general and unknown isotropic reflectances. Our method uses a pixel intensity profile, which is a sequence of radiance intensities recorded at a pixel under unknown varying directional illumination. We show that for general isotropic materials and uniformly distributed light directions, the geodesic distance between intensity profiles is linearly related to the angular difference of their corresponding surface normals, and that the intensity distribution of the intensity profile reveals reflectance properties. Based on these observations, we develop two methods for surface normal estimation; one for a general setting that uses only the recorded intensity profiles, the other for the case where a BRDF database is available while the exact BRDF of the target scene is still unknown. Quantitative and qualitative evaluations are conducted using both synthetic and real-world scenes, which show the state-of-the-art accuracy of smaller than 10 degree without using reference data and 5 degree with reference data for all 100 materials in MERL database.

  1. 1. Latin American Workshop on Total Reflection X-Ray Fluorescence (TXRF) and its Applications: TARABANA 99. Programme and Abstracts

    International Nuclear Information System (INIS)

    Vegas C, Fredy; Greaves N, Eduardo; Marco P, Lue-Meru

    1999-01-01

    It concerns about the advances in Total Reflection X-Ray Fluorescence (TXRF) instrumentation; structure, characteristic and potential of TXRF equipment used for chemical multielemental survey; TXRF: an approach to nano analysis; microanalytical investigation of environmental samples by TXRF spectrometry; TXRF of low Z elements; assessment of serum selenium levels in 2 month old sucking calves using TXRF: A powerful method to investigate the elemental composition of spheroids; environmental applications of TXRF; use of modifiers for the elimination in situ of chlorides in the analysis of TXRF; experimental methodology and analysis spectra for the determination of mercury by means of TXRF using amalgamation with gold; multielemental analysis of human amniotic fluid by use of Total Reflection X-Ray Fluorescence and rutherford forward scattering; determination of metal in samples of handmade penca; determination of oligo elements, platinum and relationship Zn/Cu in samples of blood serum and urine in oncological pediatric patient [es

  2. Effects of leaf age within growth stages of pepper and sorghum plants on leaf thickness, water, chlorophyll, and light reflectance. [in spectral vegetation discrimination

    Science.gov (United States)

    Gausman, H. W.; Cardenas, R.; Berumen, A.

    1974-01-01

    Pepper and sorghum plants (characterized by porous and compact leaf mesophylls, respectively) were used to study the influence of leaf age on light reflectance. Measurements were limited to the upper five nodal positions within each growth stage, since upper leaves make up most of the reflectance surfaces remotely sensed. The increase in leaf thickness and water content with increasing leaf age was taken into consideration, since each of these factors affects the reflectance as well as the selection of spectral wavelength intervals for optimum discrimination of vegetation.

  3. The capabilities of total reflection X-ray fluorescence in the polymeric analytical field*1

    Science.gov (United States)

    Vázquez, Cristina

    2004-08-01

    This paper presents the capabilities of total reflection X-ray fluorescence (TXRF) as analytical technique specially focused in high-viscosity polymer dispersions. Appropriate sample preparation procedures are described taking into account the time stability of these dispersions. Special remarks considering different ways for drying samples in order to obtain the most uniform deposited film are investigated focusing on the behavior of aqueous and viscous systems. Due to the difficulty found for obtaining a homogeneous mixture between sample and internal standard in such systems, the use of Compton incoherent scattering is discussed as an alternative procedure for trace quantification in high viscous systems without any mixing processes.

  4. Total site integration of light hydrocarbons separation process

    OpenAIRE

    Ulyev, L.; Vasilyev, M.; Maatouk, A.; Duic, Neven; Khusanovc, Alisher

    2016-01-01

    Ukraine is the largest consumer of hydrocarbons per unit of production in Europe (Ukraine policy review, 2006). The most important point is a reduction of energy consumption in chemical and metallurgical industries as a biggest consumer. This paper deals with energy savings potential of light hydrocarbons separation process. Energy consumption of light hydrocarbons separation process processes typical of Eastern European countries were analysed. Process Integration (PI) was used to perform a ...

  5. Bi-directional reflectance distribution function of a tungsten block for ITER divertor

    International Nuclear Information System (INIS)

    Iwamae, Atsushi; Ogawa, Hiroaki; Sugie, Tatsuo; Kusama, Yoshinori

    2012-02-01

    In order to investigate reflection properties on plasma-facing material in ITER, the bi-directional reflectance distribution function (BRDF) of a tungsten block sample has been measured. On the machining surface of the block, one-directional machining lines are engraved. Two laser diodes λ652 nm and λ473 nm were used to simulate H α and H β emissions, respectively. The reflected light is affected by the machining surface. The reflected light traces an arc when the incident light is injected in the parallel direction to the engraved line. On the other hand the reflected light traces a line shape when the incident light is injected in the perpendicular direction to the engraved lines. Ray tracing simulation qualitatively explains the experimental results. (author)

  6. Single-Molecule Light-Sheet Imaging of Suspended T Cells.

    Science.gov (United States)

    Ponjavic, Aleks; McColl, James; Carr, Alexander R; Santos, Ana Mafalda; Kulenkampff, Klara; Lippert, Anna; Davis, Simon J; Klenerman, David; Lee, Steven F

    2018-05-08

    Adaptive immune responses are initiated by triggering of the T cell receptor. Single-molecule imaging based on total internal reflection fluorescence microscopy at coverslip/basal cell interfaces is commonly used to study this process. These experiments have suggested, unexpectedly, that the diffusional behavior and organization of signaling proteins and receptors may be constrained before activation. However, it is unclear to what extent the molecular behavior and cell state is affected by the imaging conditions, i.e., by the presence of a supporting surface. In this study, we implemented single-molecule light-sheet microscopy, which enables single receptors to be directly visualized at any plane in a cell to study protein dynamics and organization in live, resting T cells. The light sheet enabled the acquisition of high-quality single-molecule fluorescence images that were comparable to those of total internal reflection fluorescence microscopy. By comparing the apical and basal surfaces of surface-contacting T cells using single-molecule light-sheet microscopy, we found that most coated-glass surfaces and supported lipid bilayers profoundly affected the diffusion of membrane proteins (T cell receptor and CD45) and that all the surfaces induced calcium influx to various degrees. Our results suggest that, when studying resting T cells, surfaces are best avoided, which we achieve here by suspending cells in agarose. Copyright © 2018. Published by Elsevier Inc.

  7. Near IR Scanning Angle Total Internal Reflection Raman Spectroscopy at Smooth Gold Films

    Energy Technology Data Exchange (ETDEWEB)

    McKee, Kristopher; Meyer, Matthew; Smith, Emily

    2012-04-13

    Total internal reflection (TIR) Raman and reflectivity spectra were collected for nonresonant analytes as a function of incident angle at sapphire or sapphire/smooth 50 nm gold interfaces using 785 nm excitation. For both interfaces, the Raman signal as a function of incident angle is well-modeled by the calculated interfacial mean square electric field (MSEF) relative to the incident field times the thickness of the layer being probed in the Raman measurement (D{sub RS}). The Raman scatter was reproducibly enhanced at the interface containing a gold film relative to the sapphire interface by a factor of 4.3–4.6 for aqueous pyridine or 2.2–3.7 for neat nitrobenzene, depending on the analyzed vibrational mode. The mechanism for the increased Raman signal is the enhanced MSEF at incident angles where propagating surface plasmons are excited in the metal film. The background from the TIR prism was reduced by 89–95% with the addition of the gold film, and the percent relative uncertainty in peak area was reduced from 15 to 1.7% for the 1347 cm–1 mode of nitrobenzene. Single monolayers of benzenethiol (S/N = 6.8) and 4-mercaptopyridine (S/N = 16.5) on gold films were measured by TIR Raman spectroscopy with 785 nm excitation (210 mW) without resonant enhancement in 1 min.

  8. The differential equation of an arbitrary reflecting surface

    Science.gov (United States)

    Melka, Richard F.; Berrettini, Vincent D.; Yousif, Hashim A.

    2018-05-01

    A differential equation describing the reflection of a light ray incident upon an arbitrary reflecting surface is obtained using the law of reflection. The derived equation is written in terms of a parameter and the value of this parameter determines the nature of the reflecting surface. Under various parametric constraints, the solution of the differential equation leads to the various conic surfaces but is not generally solvable. In addition, the dynamics of the light reflections from the conic surfaces are executed in the Mathematica software. Our derivation is the converse of the traditional approach and our analysis assumes a relation between the object distance and the image distance. This leads to the differential equation of the reflecting surface.

  9. Prismatic TIR (total internal reflection) low-concentration PV (photovoltaics)-integrated façade for low latitudes

    International Nuclear Information System (INIS)

    Sabry, Mohamed

    2016-01-01

    Low-concentration Façade-integrated Photovoltaic system in the form of TIR (total internal reflection) prismatic segmented façade could play an effective role in reducing the direct component of solar radiation transmitting through buildings, hence reducing both cooling and artificial lighting load on such buildings. A prismatic segmented façade is capable of allowing diffused skylight to transmit through it to the building interior, while preventing most of the direct solar radiation and converting it into clean energy by means of the integrated PV (​photovoltaics) cells. A range of prismatic TIR segmented façades with different head angles has been designed based on the geographical latitude of the chosen location. Each façade configuration is simulated by ray-tracing technique and its performance is investigated against realistic direct solar radiation data in two clear sky days representing summer and winter of the targeted location. Ray tracing simulations revealed that all of the selected configurations could collect most of the direct solar radiation in summer. In contrary, larger head angle of the segmented façade could collect wider intervals around the noon time till reaching a head angle of 23° at which most of the incident direct solar radiation could be collected. - Highlights: • 5 different head angles of prismatic segmented PV-integrated Façade are ray-traced. • Transmitted and PV-collected solar radiation percentages are determined. • DNI daily profiles with associated solar altitudes and azimuth data are simulated. • Expected transmitted and PV collected solar radiation are calculated for the proposed segments.

  10. Characterization of silver halide fiber optics and hollow silica waveguides for use in the construction of a mid-infrared attenuated total reflection fourier transform infrared (ATR FT-IR) spectroscopy probe.

    Science.gov (United States)

    Damin, Craig A; Sommer, André J

    2013-11-01

    Advances in fiber optic materials have allowed for the construction of fibers and waveguides capable of transmitting infrared radiation. An investigation of the transmission characteristics associated with two commonly used types of infrared-transmitting fibers/waveguides for prospective use in a fiber/waveguide-coupled attenuated total internal reflection (ATR) probe was performed. Characterization of silver halide polycrystalline fiber optics and hollow silica waveguides was done on the basis of the transmission of infrared light using a conventional fiber optic coupling accessory and an infrared microscope. Using the fiber optic coupling accessory, the average percent transmission for three silver halide fibers was 18.1 ± 6.1% relative to a benchtop reflection accessory. The average transmission for two hollow waveguides (HWGs) using the coupling accessory was 8.0 ± 0.3%. (Uncertainties in the relative percent transmission represent the standard deviations.) Reduced transmission observed for the HWGs was attributed to the high numerical aperture of the coupling accessory. Characterization of the fibers/waveguides using a zinc selenide lens objective on an infrared microscope indicated 24.1 ± 7.2% of the initial light input into the silver halide fibers was transmitted. Percent transmission obtained for the HWGs was 98.7 ± 0.1%. Increased transmission using the HWGs resulted from the absence or minimization of insertion and scattering losses due to the hollow air core and a better-matched numerical aperture. The effect of bending on the transmission characteristics of the fibers/waveguides was also investigated. Significant deviations in the transmission of infrared light by the solid-core silver halide fibers were observed for various bending angles. Percent transmission greater than 98% was consistently observed for the HWGs at the bending angles. The combined benefits of high percent transmission, reproducible instrument responses, and increased bending

  11. Origin of Infrared Light Modulation in Reflectance-Mode Photoplethysmography.

    Directory of Open Access Journals (Sweden)

    Igor S Sidorov

    Full Text Available We recently pointed out the important role of dermis deformation by pulsating arterial pressure in the formation of a photoplethysmographic signal at green light. The aim of this study was to explore the role of this novel finding in near-infrared (NIR light. A light-emitting diode (LED-based imaging photoplethysmography (IPPG system was used to detect spatial distribution of blood pulsations under frame-to-frame switching green and NIR illumination in the palms of 34 healthy individuals. We observed a significant increase of light-intensity modulation at the heartbeat frequency for both illuminating wavelengths after a palm was contacted with a glass plate. Strong positive correlation between data measured at green and NIR light was found, suggesting that the same signal was read independently from the depth of penetration. Analysis of the data shows that an essential part of remitted NIR light is modulated in time as a result of elastic deformations of dermis caused by variable blood pressure in the arteries. Our observations suggest that in contrast with the classical model, photoplethysmographic waveform originates from the modulation of the density of capillaries caused by the variable pressure applied to the skin from large blood vessels. Particularly, beat-to-beat transmural pressure in arteries compresses/decompresses the dermis and deforms its connective-tissue components, thus affecting the distance between the capillaries, which results in the modulation of absorption and scattering coefficients of both green and NIR light. These findings are important for the correct interpretation of this widely used medical technique, which may have novel applications in diagnosis and treatment monitoring of aging and skin diseases.

  12. Enhanced spin Hall effect of tunneling light in hyperbolic metamaterial waveguide.

    Science.gov (United States)

    Tang, Tingting; Li, Chaoyang; Luo, Li

    2016-08-01

    Giant enhancement of spin Hall effect of tunneling light (SHETL) is theoretically proposed in a frustrated total internal reflection (FTIR) structure with hyperbolic metamaterial (HMM). We calculate the transverse shift of right-circularly polarized light in a SiO2-air-HMM-air-SiO2 waveguide and analyze the physical mechanism of the enhanced SHETL. The HMM anisotropy can greatly increase the transverse shift of polarized light even though HMM loss might reduce it. Compared with transverse shift of transmitted light through a single HMM slab with ZnAlO/ZnO multilayer, the maximum transverse shift of tunneling light through a FTIR structure with identical HMM can be significantly enlarged by more than three times which reaches -38 μm without any amplification method.

  13. Front lighted optical tooling method and apparatus

    International Nuclear Information System (INIS)

    Stone, W. J.

    1985-01-01

    An optical tooling method and apparatus uses a front lighted shadowgraphic technique to enhance visual contrast of reflected light. The apparatus includes an optical assembly including a fiducial mark, such as cross hairs, reflecting polarized light with a first polarization, a polarizing element backing the fiducial mark and a reflective surface backing the polarizing element for reflecting polarized light bypassing the fiducial mark and traveling through the polarizing element. The light reflected by the reflecting surface is directed through a second pass of the polarizing element toward the frontal direction with a polarization differing from the polarization of the light reflected by the fiducial mark. When used as a tooling target, the optical assembly may be mounted directly to a reference surface or may be secured in a mounting, such as a magnetic mounting. The optical assembly may also be mounted in a plane defining structure and used as a spherometer in conjunction with an optical depth measuring instrument. A method of measuring a radius of curvature of an unknown surface includes positioning the spherometer on a surface between the surface and a depth measuring optical instrument. As the spherometer is frontally illuminated, the distance from the depth measuring instrument to the fiducial mark and the underlying surface are alternately measured and the difference in these measurements is used as the sagittal height to calculate a radius of curvature

  14. Indoor Lighting Facilities

    Science.gov (United States)

    Matsushima, Koji; Saito, Yoshinori; Ichikawa, Shigenori; Kawauchi, Takao; Tanaka, Tsuneo; Hirano, Rika; Tazuke, Fuyuki

    According to the statistics on building construction floor area from the Ministry of Land, Infrastructure, Transport and Tourism, the total floor area of building construction started in Japan in 2007 was 160,991 thousand square meters, or 14.8% less than the area of the previous year, and the reduction was the first reduction in the past five years. The office markets in Tokyo and Nagoya were active, as represented by the supplies of skyscrapers, and energy saving measures, such as the adoption of high efficiency lighting equipment, the control for initial stage illuminance, daylight harvesting, and the use of occupancy sensors, were well established. In the field of public construction, including museums, multi-purpose halls, and religious buildings, the total area of the new construction was 10.8% less than the total for the previous year, and this reduction was a continuation of an eleven-year trend. In spaces with high ceiling, the innovation for easy replacement of light sources used with reflection mirror systems and optical fibers was noted. Hospitals adapted to the expectation for improved services in their selection of lighting facilities to improve the residential environment for patients while taking into consideration the needs of the aging population, by their use of devices in corridors to help maintain a continuity of light. In libraries, a pendant system was developed to illuminate both ceilings and book shelves. In the field of theaters and halls, the time limit for repairing existing systems had come for the large facilities that were opened during the theater and hall construction boom of the 1960s through 1980s, and around 26 renovations were done. Almost all the renovations were conversions to intelligent dimming systems and lighting control desks. In the field of stores and commercial facilities, the atmosphere and glitter of the selling floor was produced by new light sources, such as ceramic metal halide lamps and LEDs, which have high

  15. Ultraviolet reflecting photonic microstructures in the King Penguin beak.

    Science.gov (United States)

    Dresp, Birgitta; Jouventin, Pierre; Langley, Keith

    2005-09-22

    King and emperor penguins (Aptenodytes patagonicus and Aptenodytes forsteri) are the only species of marine birds so far known to reflect ultraviolet (UV) light from their beaks. Unlike humans, most birds perceive UV light and several species communicate using the near UV spectrum. Indeed, UV reflectance in addition to the colour of songbird feathers has been recognized as an important signal when choosing a mate. The king penguin is endowed with several highly coloured ornaments, notably its beak horn and breast and auricular plumage, but only its beak reflects UV, a property considered to influence its sexual attraction. Because no avian UV-reflecting pigments have yet been identified, the origin of such reflections is probably structural. In an attempt to identify the structures that give rise to UV reflectance, we combined reflectance spectrophotometry and morphological analysis by both light and electron microscopy, after experimental removal of surface layers of the beak horn. Here, we characterize for the first time a multilayer reflector photonic microstructure that produces the UV reflections in the king penguin beak.

  16. Determination of carbon in natural freshwater biofilms with total reflection X-ray fluorescence spectrometry

    International Nuclear Information System (INIS)

    Ovari, M.; Streli, C.; Wobrauschek, P.; Zaray, Gy.

    2009-01-01

    There is a growing interest in determination of low Z elements, i.e., carbon to phosphorus, in biological samples. Total reflection X-ray fluorescence spectrometry (TXRF) has been already established as suitable trace element analytical method with low sample demand and quite good quantification limits. Recently, the determinable element range was extended towards Z = 6 (carbon). Biofilms can be used for biomonioring purposes in the aquatic environment. Besides the trace metals, especially the determination of the carbon content is important for the better understanding of the early stage of biofilm formation. For this, an ATI low Z spectrometer equipped with Cr-anode X-ray tube, multilayer monochromator, vacuum chamber, and a Si(Li) detector with ultra thin window was used. Biofilms were grown on two different artificial supports (granite and plexiglass), freeze dried, suspended in high purity water and analyzed. As an internal standard the natural titanium content of the biofilms was used. The accuracy of the method was checked by total carbon measurement using a combusting carbon analyzer.

  17. Determination of carbon in natural freshwater biofilms with total reflection X-ray fluorescence spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Ovari, M. [Department of Analytical Chemistry, Eoetvoes University, Budapest, H-1117, Budapest, Pazmany Peter stny. 1/a. (Hungary)], E-mail: ovari@chem.elte.hu; Streli, C.; Wobrauschek, P. [Atominstitut of the Austrian Universities, TU-Wien, Stadionallee 2, A-1020, Wien (Austria); Zaray, Gy. [Department of Analytical Chemistry, Eoetvoes University, Budapest, H-1117, Budapest, Pazmany Peter stny. 1/a. (Hungary); Cooperative Research Centre of Environmental Chemistry, Eoetvoes University, Budapest, H-1117, Budapest, Pazmany Peter stny. 1/a. (Hungary)

    2009-08-15

    There is a growing interest in determination of low Z elements, i.e., carbon to phosphorus, in biological samples. Total reflection X-ray fluorescence spectrometry (TXRF) has been already established as suitable trace element analytical method with low sample demand and quite good quantification limits. Recently, the determinable element range was extended towards Z = 6 (carbon). Biofilms can be used for biomonioring purposes in the aquatic environment. Besides the trace metals, especially the determination of the carbon content is important for the better understanding of the early stage of biofilm formation. For this, an ATI low Z spectrometer equipped with Cr-anode X-ray tube, multilayer monochromator, vacuum chamber, and a Si(Li) detector with ultra thin window was used. Biofilms were grown on two different artificial supports (granite and plexiglass), freeze dried, suspended in high purity water and analyzed. As an internal standard the natural titanium content of the biofilms was used. The accuracy of the method was checked by total carbon measurement using a combusting carbon analyzer.

  18. Spectral curves of surface reflectance in some Antarctic regions

    International Nuclear Information System (INIS)

    Lupi, A.; Tomasi, C.; Orsini, A.; Cacciari, A.; Vitale, V.; Georgiadis, T.; Casacchia, R.; Salvatori, R.; Salvi, S.

    2001-01-01

    Four surface reflectance models of solar radiation were determined by examining several sets of field measurements taken for clear-sky conditions at various sites in Antarctica. Each model consists of the mean spectral curve of surface reflectance in the 0.25-2.7 μm wavelength range and of the dependence curve of total abedo on the solar elevation angle h, within the range from 5 0 to 55 0 . The TNB (Terra Nova Bay) model refers to a rocky terrain where granites are predominant; the NIS (Nansen Ice Sheet) model to a glacier surface made uneven by sastrugi and streaked by irregular fractures; the HAP (High Altitude Plateau) model to a flat ice surface covered by fresh snow and scored by light sastrugi; and the RIS (Ross Ice Shelf) model to an area covered by the sea ice pack presenting many discontinuities in the reflectance features, due to melt water lakes, puddles, refrozen ice and snow pots. The reflectance curve obtained for the TNB model presents gradually increasing values as wavelength increases through the visible spectral range and almost constant values at infrared wavelengths, giving a total albedo value equal to 0.264 at = 30 0 , which increases by about 80% through the lower range of h and decreases by 12% through the upper range. The reflectance curves of the NIS, HAP and RIS models are all peaked at visible wavelengths and exhibit decreasing values throughout the infrared spectral range, giving values of total albedo equal to 0.464, 0.738 and 0.426 at h 30 0 , respectively. These values were estimated to increase by 8-14% as h decreases from 30 0 to 5 0 and to decrease by 2-4% only as h increases from 30 0 to 55 0

  19. High accuracy subwavelength distance measurements: A variable-angle standing-wave total-internal-reflection optical microscope

    International Nuclear Information System (INIS)

    Haynie, A.; Min, T.-J.; Luan, L.; Mu, W.; Ketterson, J. B.

    2009-01-01

    We describe an extension of the total-internal-reflection microscopy technique that permits direct in-plane distance measurements with high accuracy (<10 nm) over a wide range of separations. This high position accuracy arises from the creation of a standing evanescent wave and the ability to sweep the nodal positions (intensity minima of the standing wave) in a controlled manner via both the incident angle and the relative phase of the incoming laser beams. Some control over the vertical resolution is available through the ability to scan the incoming angle and with it the evanescent penetration depth.

  20. Modeling the effect of reflection from metallic walls on spectroscopic measurements

    International Nuclear Information System (INIS)

    Zastrow, K.-D.; Keatings, S. R.; O'Mullane, M. G.; Marot, L.; Temmerman, G. de

    2008-01-01

    A modification of JET is presently being prepared to bring operational experience with ITER-like first wall (Be) and divertor (W) materials, geometry and plasma parameters. Reflectivity measurements of JET sample tiles have been performed and the data are used within a simplified model of the JET and ITER vessels to predict additional contributions to quantitative spectroscopic measurements. The most general method to characterize reflectivity is the bidirectional reflection distribution function (BRDF). For extended sources however, such as bremsstrahlung and edge emission of fuel and intrinsic impurities, the results obtained in the modeling are almost as accurate if the total reflectivity with ideal Lambertian angular dependence is used. This is in contrast to the experience in other communities, such as optical design, lighting design, or rendering who deal mostly with pointlike light sources. This result is so far based on a very limited set of measurements and will be reassessed when more detailed BRDF measurements of JET tiles have been made. If it is true it offers the possibility of in situ monitoring of the reflectivity of selected parts of the wall during exposure to plasma operation, while remeasurement of the BRDF is performed during interventions. For a closed vessel structure such as ITER, it is important to consider multiple reflections. This makes it more important to represent the whole of the vessel reasonably accurately in the model, which on the other hand is easier to achieve than for the more complex internal structure of JET. In both cases the dominant contribution is from the first reflection, and a detailed model of the areas intersected by lines of sight of diagnostic interest is required.

  1. ZnO/Al{sub 2}O{sub 3} core/shell nanorods array as excellent anti-reflection layers on silicon solar cells

    Energy Technology Data Exchange (ETDEWEB)

    Lung, Chun-Ming; Wang, Wei-Cheng [Department of Materials Science and Engineering, National Taiwan University, No. 1, Sec. 4, Roosevelt Road, Taipei, 10617, Taiwan (China); Chen, Ching-Hsiang [Graduate Institute of Applied Science and Technology, National Taiwan University of Science and Technology, No. 43, Section 4, Keelung Road, Taipei, 106, Taiwan (China); Chen, Liang-Yih, E-mail: sampras@mail.ntust.edu.tw [Department of Chemical Engineering, National Taiwan University of Science and Technology, No. 43, Section 4, Keelung Road, Taipei, 106, Taiwan (China); Chen, Miin-Jang, E-mail: mjchen@ntu.edu.tw [Department of Materials Science and Engineering, National Taiwan University, No. 1, Sec. 4, Roosevelt Road, Taipei, 10617, Taiwan (China)

    2016-09-01

    A simple, low-temperature hydrothermal method and atomic layer deposition (ALD) were used to fabricate ZnO nanostructures as subwavelength-structure antireflection layers (SWS ARLs) on Si solar cells. ZnO seed layers with wafer-scale uniformity were prepared, and ALD was used to reproduce two types of ZnO-based structures, nanorod arrays (NRAs) and nanotip arrays (NTAs). The study examined diammonium phosphate concentrations during growth, conducted simulations based on three-dimensional finite-difference time-domain and reflection analyses, performed X-ray diffractometer, field-emission scanning electron microscope, and high-resolution transmission electron microscope characterizations, measured total reflectance spectra by using a spectrophotometer with integrated spheres, and ran solar simulations to determine the efficiency of the Si solar cells. Coating the ZnO NTAs on the Si solar cells yielded a low total reflectance over a broad band range and produced omnidirectional light scattering on the cells, causing incident light to have a shallow penetration depth near the p–n junction and leading to an increase in short current density ({sub Jsc}). Coating the ZnO NTAs with an Al{sub 2}O{sub 3} shell induced continuous variation in the refractive index, further decreasing the total reflectance to approximately 5.5%, and protected the ZnO NTAs from the harmful acidic environment. Significantly increasing the J{sub sc} and η levels of the Si solar cells, the Al{sub 2}O{sub 3}@ZnO-NTA antireflection structure produced a high efficiency of 17.79%. Its superior performance, including low and wideband reflectance, a low process temperature, and a significant increase in efficiency, indicates the potential of this antireflective structure for enhancing solar cell efficiency in photovoltaic devices. - Highlights: • ZnO nanotip arrays were synthesized by hydrothermal methods as antireflection layer. • The total reflectance is low around 7.8% from 400 nm to 1000

  2. Discharge lamp with reflective jacket

    Science.gov (United States)

    MacLennan, Donald A.; Turner, Brian P.; Kipling, Kent

    2001-01-01

    A discharge lamp includes an envelope, a fill which emits light when excited disposed in the envelope, a source of excitation power coupled to the fill to excite the fill and cause the fill to emit light, and a reflector disposed around the envelope and defining an opening, the reflector being configured to reflect some of the light emitted by the fill back into the fill while allowing some light to exit through the opening. The reflector may be made from a material having a similar thermal index of expansion as compared to the envelope and which is closely spaced to the envelope. The envelope material may be quartz and the reflector material may be either silica or alumina. The reflector may be formed as a jacket having a rigid structure which does not adhere to the envelope. The lamp may further include an optical clement spaced from the envelope and configured to reflect an unwanted component of light which exited the envelope back into the envelope through the opening in the reflector. Light which can be beneficially recaptured includes selected wavelength regions, a selected polarization, and selected angular components.

  3. Characterization of southern yellow pine bark layers by Attenuated Total Reflectance (ATR) and Fourier Transform Infrared (FT-IR) Spectroscopy

    Science.gov (United States)

    Thomas L. Eberhardt

    2009-01-01

    The outer bark (rhytidome) of the southern yellow pines is a complex structure comprised of alternating layers of obliterated phloem and periderm tissues, with the latter comprised of three layers, those being phellem, phellogen, and phelloderm. An attenuated total reflectance (ATR) sampling accessory, coupled with a Fourier transform infrared (FTIR) spectrometer,...

  4. Disposable attenuated total reflection-infrared crystals from silicon wafer: a versatile approach to surface infrared spectroscopy.

    Science.gov (United States)

    Karabudak, Engin; Kas, Recep; Ogieglo, Wojciech; Rafieian, Damon; Schlautmann, Stefan; Lammertink, R G H; Gardeniers, Han J G E; Mul, Guido

    2013-01-02

    Attenuated total reflection-infrared (ATR-IR) spectroscopy is increasingly used to characterize solids and liquids as well as (catalytic) chemical conversion. Here we demonstrate that a piece of silicon wafer cut by a dicing machine or cleaved manually can be used as disposable internal reflection element (IRE) without the need for polishing and laborious edge preparation. Technical aspects, fundamental differences, and pros and cons of these novel disposable IREs and commercial IREs are discussed. The use of a crystal (the Si wafer) in a disposable manner enables simultaneous preparation and analysis of substrates and application of ATR spectroscopy in high temperature processes that may lead to irreversible interaction between the crystal and the substrate. As representative application examples, the disposable IREs were used to study high temperature thermal decomposition and chemical changes of polyvinyl alcohol (PVA) in a titania (TiO(2)) matrix and assemblies of 65-450 nm thick polystyrene (PS) films.

  5. The Direct Lighting Computation in Global Illumination Methods

    Science.gov (United States)

    Wang, Changyaw Allen

    1994-01-01

    Creating realistic images is a computationally expensive process, but it is very important for applications such as interior design, product design, education, virtual reality, and movie special effects. To generate realistic images, state-of-art rendering techniques are employed to simulate global illumination, which accounts for the interreflection of light among objects. In this document, we formalize the global illumination problem into a eight -dimensional integral and discuss various methods that can accelerate the process of approximating this integral. We focus on the direct lighting computation, which accounts for the light reaching the viewer from the emitting sources after exactly one reflection, Monte Carlo sampling methods, and light source simplification. Results include a new sample generation method, a framework for the prediction of the total number of samples used in a solution, and a generalized Monte Carlo approach for computing the direct lighting from an environment which for the first time makes ray tracing feasible for highly complex environments.

  6. Determining the primary cosmic ray energy from the total flux of Cherenkov light measured at the Yakutsk EAS array

    International Nuclear Information System (INIS)

    Ivanov, A. A.; Knurenko, S. P.; Sleptsov, I. E.

    2007-01-01

    We present a method for determining the energy of the primary particle that generates an extensive air shower (EAS) of comic rays based on measuring the total flux of Cherenkov light from the shower. Applying this method to Cherenkov light measurements at the Yakutsk EAS array has allowed us to construct the cosmic ray energy spectrum in the range 10 15 - 3 x 10 19 eV

  7. Pigment particles analysis with a total reflection X-ray fluorescence spectrometer: study of influence of instrumental parameters

    Energy Technology Data Exchange (ETDEWEB)

    Coccato, Alessia; Vandenabeele, Peter [Ghent University, Department of Archaeology, Ghent (Belgium); Vekemans, Bart; Vincze, Laszlo; Moens, Luc [Ghent University, Department of Analytical Chemistry, Ghent (Belgium)

    2016-12-15

    Total reflection X-ray fluorescence (TXRF) analysis is an excellent tool to determine major, minor and trace elements in minuscule amounts of samples, making this technique very suitable for pigment analysis. Collecting minuscule amounts of pigment material from precious works of art by means of a cotton swab is a well-accepted sampling method, but poses specific challenges when TXRF is to be used for the characterization of the unknown material. (orig.)

  8. Metals determination in coffee sample by total reflection X-ray fluorescence analysis (TXRF)

    International Nuclear Information System (INIS)

    Vives, Ana Elisa Sirito de

    2005-01-01

    The objective of this study was to evaluate the inorganic concentration in five brands of coffee, three of them nationally marketed and the others of an exportation kind. The samples were prepared by infusion with deionized water. To carry out the calibration, standard solutions were prepared with different concentrations of Al, Si, K, Ca, Ti, Cr, Fe, Ni, Zn and Se. The measurements were carried out using a white beam of synchrotron radiation for excitation and a Si (Li) semiconductor detector for detection. By employing Synchrotron Radiation Total Reflection X-Ray Fluorescence Analysis (SR-TXRF) it was possible to evaluate the concentrations of P, S, Cl, K, Ca, Mn, Fe, Cu, Zn, Rb and Ba. The detection limits for 300 s counting time were in the range of 0.03 (Ca) to 30 ng.g -1 (Rb), respectively. (author)

  9. Single particle transfer for quantitative analysis with total-reflection X-ray fluorescence spectrometry

    International Nuclear Information System (INIS)

    Esaka, Fumitaka; Esaka, Konomi T.; Magara, Masaaki; Sakurai, Satoshi; Usuda, Shigekazu; Watanabe, Kazuo

    2006-01-01

    The technique of single particle transfer was applied to quantitative analysis with total-reflection X-ray fluorescence (TXRF) spectrometry. The technique was evaluated by performing quantitative analysis of individual Cu particles with diameters between 3.9 and 13.2 μm. The direct quantitative analysis of the Cu particle transferred onto a Si carrier gave a discrepancy between measured and calculated Cu amounts due to the absorption effects of incident and fluorescent X-rays within the particle. By the correction for the absorption effects, the Cu amounts in individual particles could be determined with the deviation within 10.5%. When the Cu particles were dissolved with HNO 3 solution prior to the TXRF analysis, the deviation was improved to be within 3.8%. In this case, no correction for the absorption effects was needed for quantification

  10. Metals determination in coffee sample by total reflection X-ray fluorescence analysis (TXRF)

    Energy Technology Data Exchange (ETDEWEB)

    Vives, Ana Elisa Sirito de [Universidade Metodista de Piracicaba (UNIMEP), Santa Barbara D' Oeste, SP (Brazil). Faculdade de Engenharia, Arquitetura e Urbanismo]. E-mail: aesvives@unimep.br; Moreira, Silvana [Universidade Estadual de Campinas, SP (Brazil). Faculdade de Engenharia Civil, Arquitetura e Urbanismo]. E-mail: Silvana@fec.unicamp.br; Brienza, Sandra Maria Boscolo [ Universidade Metodista de Piracicaba (UNIMEP), Piracicaba, SP (Brazil). Faculdade de Ciencias Matematicas, da Natureza e de Tecnologia da Informacao]. E-mail: sbrienza@unimep.br; Zucchi, Orgheda Luiza Araujo Domingues [Sao Paulo Univ., Ribeirao Preto, SP (Brazil). Faculdade de Ciencias Farmaceuticas]. E-mail: olzucchi@fcfrp.usp.br; Nascimento Filho, Virgilio Franco do [Centro de Energia Nuclear na Agricultura (CENA), Piracicaba, SP (Brazil)]. E-mail: virgilio@cena.usp.br

    2005-07-01

    The objective of this study was to evaluate the inorganic concentration in five brands of coffee, three of them nationally marketed and the others of an exportation kind. The samples were prepared by infusion with deionized water. To carry out the calibration, standard solutions were prepared with different concentrations of Al, Si, K, Ca, Ti, Cr, Fe, Ni, Zn and Se. The measurements were carried out using a white beam of synchrotron radiation for excitation and a Si (Li) semiconductor detector for detection. By employing Synchrotron Radiation Total Reflection X-Ray Fluorescence Analysis (SR-TXRF) it was possible to evaluate the concentrations of P, S, Cl, K, Ca, Mn, Fe, Cu, Zn, Rb and Ba. The detection limits for 300 s counting time were in the range of 0.03 (Ca) to 30 ng.g{sup -1} (Rb), respectively. (author)

  11. In Situ Focused Beam Reflectance Measurement (FBRM, Attenuated Total Reflectance Fourier Transform Infrared (ATR-FTIR and Raman Characterization of the Polymorphic Transformation of Carbamazepine

    Directory of Open Access Journals (Sweden)

    Sohrab Rohani

    2012-02-01

    Full Text Available The objective of this work was to study the polymorphic transformation of carbamazepine from Form II to Form III in 1-propanol during seeded isothermal batch crystallization. First, the pure Form II and Form III were obtained and characterized. Then their solubilities and metastable zone limits were measured by in-situ attenuated total reflectance Fourier transform infrared (ATR-FTIR spectroscopy and focused beam reflectance measurement (FBRM. A transition temperature at about 34.2 °C was deduced suggesting the enantiotropic nature of this compound over the studied temperature range. To quantify the polymorph ratio during the transformation process, a new in-situ quantitative method was developed to measure the fraction of Form II by Raman spectroscopy. Successful tracking of the nucleation of the stable form and the transformation from Form II to Form III during isothermal crystallization was achieved by Raman spectroscopy and FBRM. The results from these three in-situ techniques, FBRM, FTIR and Raman were consistent with each other. The results showed a strong dependency on the amount of seeds added during isothermal crystallization.

  12. Total internal reflection sum-frequency generation spectroscopy and dense gold nanoparticles monolayer: a route for probing adsorbed molecules

    International Nuclear Information System (INIS)

    Tourillon, Gerard; Dreesen, Laurent; Volcke, Cedric; Sartenaer, Yannick; Thiry, Paul A; Peremans, Andre

    2007-01-01

    We show that sum-frequency generation spectroscopy performed in the total internal reflection configuration (TIR-SFG) combined with a dense gold nanoparticles monolayer allows us to study, with an excellent signal to noise ratio and high signal to background ratio, the conformation of adsorbed molecules. Dodecanethiol (DDT) was used as probe molecules in order to assess the potentialities of the approach. An enhancement of more than one order of magnitude of the SFG signals arising from the adsorbed species is observed with the TIR geometry compared to the external reflection one while the SFG non-resonant contribution remains the same for both configurations. Although further work is required to fully understand the origin of the SFG process on nanoparticles, our work opens new possibilities for studying nanostructures

  13. Built-in hyperspectral camera for smartphone in visible, near-infrared and middle-infrared lights region (second report): sensitivity improvement of Fourier-spectroscopic imaging to detect diffuse reflection lights from internal human tissues for healthcare sensors

    Science.gov (United States)

    Kawashima, Natsumi; Hosono, Satsuki; Ishimaru, Ichiro

    2016-05-01

    We proposed the snapshot-type Fourier spectroscopic imaging for smartphone that was mentioned in 1st. report in this conference. For spectroscopic components analysis, such as non-invasive blood glucose sensors, the diffuse reflection lights from internal human skins are very weak for conventional hyperspectral cameras, such as AOTF (Acousto-Optic Tunable Filter) type. Furthermore, it is well known that the spectral absorption of mid-infrared lights or Raman spectroscopy especially in long wavelength region is effective to distinguish specific biomedical components quantitatively, such as glucose concentration. But the main issue was that photon energies of middle infrared lights and light intensities of Raman scattering are extremely weak. For improving sensitivity of our spectroscopic imager, the wide-field-stop & beam-expansion method was proposed. Our line spectroscopic imager introduced a single slit for field stop on the conjugate objective plane. Obviously to increase detected light intensities, the wider slit width of the field stop makes light intensities higher, regardless of deterioration of spatial resolutions. Because our method is based on wavefront-division interferometry, it becomes problems that the wider width of single slit makes the diffraction angle narrower. This means that the narrower diameter of collimated objective beams deteriorates visibilities of interferograms. By installing the relative inclined phaseshifter onto optical Fourier transform plane of infinity corrected optical systems, the collimated half flux of objective beams derived from single-bright points on objective surface penetrate through the wedge prism and the cuboid glass respectively. These two beams interfere each other and form the infererogram as spatial fringe patterns. Thus, we installed concave-cylindrical lens between the wider slit and objective lens as a beam expander. We successfully obtained the spectroscopic characters of hemoglobin from reflected lights from

  14. Study of Laser Reflectivity on Skin

    International Nuclear Information System (INIS)

    Oidor-Garcia, J. J. J.; Trevino-Palacios, C. G.

    2008-01-01

    The response to the light on the skin can be manifested as temperature increase or creation of biochemical byproducts, in which further studies are required to asset the light effect. This response changes the average response over time and can produce discrepancies between similar studies. In this work we present a Low Level Laser Therapy (LLLT) study with feedback. We study the time response reflectivity of a 980 nm laser diode of 25 mW modulated at frequencies close to 40 kHz and detect the reflected light on a silicon photodiode, finding no direct correlation between different test points or individuals, while finding reproducible responses within the same individual and test point

  15. Inverted-conical light guide for crosstalk reduction in tightly-packed scintillator matrix and MAPMT assembly

    DEFF Research Database (Denmark)

    Chang, Y.-Y.; Chen, P.; Huang, J.-J.

    2015-01-01

    In this paper we present the Inverted-Conical light guide designed for optical crosstalk reduction in the scintillator-MAPMT assemblies. The research was motivated by the 30% crosstalk observed in UFFO X-ray telescope, UBAT, during the preliminary calibration with MAPMTs of 64 2.88 × 2.88 mm2...... pixels and identically gridded YSO crystal matrices. We began the study with the energy and crosstalk calibrations of the detector, then we constructed a GEANT4 simulation with the customized metallic film model as the MAPMT photocathode. The simulation reproduced more than 70% of the crosstalk...... and explained it as a consequence of the total reflection produced by the photocathode. The result indicated that the crosstalk mechanism could be a common case in most of the contact-assembled scintillation detectors. The concept of the Inverted-Conical light guide was to suppress the total reflection...

  16. Fundamental quantification procedure for total reflection X-ray fluorescence spectra analysis and elements determination

    International Nuclear Information System (INIS)

    Wegrzynek, D.; Holynska, B.

    1997-01-01

    A method for the determination of the concentrations of elements in particulate-like samples measured in total reflection geometry is proposed. In the proposed method the fundamental parameters are utilized for calculating the sensitivities of elements and an internal standard is used to account for the unknown mass per unit area of a sample and geometrical constant of the spectrometer. The modification of the primary excitation spectrum on its way to a sample has been taken into consideration. The concentrations of the elements to be determined are calculated simultaneously with the spectra deconvolution procedure. In the process of quantitative analysis the intensities of all X-ray peaks corresponding to K and L-series lines present in the analyzed spectrum are taken into account. (Author)

  17. Registration of T-2 mycotoxin with total internal reflection ellipsometry and QCM impedance methods.

    Science.gov (United States)

    Nabok, A V; Tsargorodskaya, A; Holloway, A; Starodub, N F; Gojster, O

    2007-01-15

    A sensitive optical method of total internal reflection ellipsometry (TIRE) in conjunction with immune assay approach was exploited for the registration of T-2 mycotoxin in a wide range of concentrations from 100 microg/ml down to 0.15 ng/ml. Association constants of 1.4x10(6) and 1.9x10(7)mol(-1)s for poly- and monoclonal T-2 antibodies, respectively, were evaluated from TIRE kinetic measurements. According to TIRE data fitting, binding of T-2 molecules to antibodies (at saturation) has resulted in the increase in adsorbed layer thickness of 4-5 nm. The QCM impedance measurements data showed anomalously large mass increase and film softening, most likely, due to the binding of large T-2 aggregates to antibodies.

  18. Live Imaging of Cellular Internalization of Single Colloidal Particle by Combined Label-Free and Fluorescence Total Internal Reflection Microscopy.

    Science.gov (United States)

    Byrne, Gerard D; Vllasaliu, Driton; Falcone, Franco H; Somekh, Michael G; Stolnik, Snjezana

    2015-11-02

    In this work we utilize the combination of label-free total internal reflection microscopy and total internal reflectance fluorescence (TIRM/TIRF) microscopy to achieve a simultaneous, live imaging of single, label-free colloidal particle endocytosis by individual cells. The TIRM arm of the microscope enables label free imaging of the colloid and cell membrane features, while the TIRF arm images the dynamics of fluorescent-labeled clathrin (protein involved in endocytosis via clathrin pathway), expressed in transfected 3T3 fibroblasts cells. Using a model polymeric colloid and cells with a fluorescently tagged clathrin endocytosis pathway, we demonstrate that wide field TIRM/TIRF coimaging enables live visualization of the process of colloidal particle interaction with the labeled cell structure, which is valuable for discerning the membrane events and route of colloid internalization by the cell. We further show that 500 nm in diameter model polystyrene colloid associates with clathrin, prior to and during its cellular internalization. This association is not apparent with larger, 1 μm in diameter colloids, indicating an upper particle size limit for clathrin-mediated endocytosis.

  19. Creation of a reflecting formula to determine a patient's indication for undergoing total knee arthroplasty.

    Science.gov (United States)

    Chan, Wing P; Hsu, Shu-Mei; Huang, Guo-Shu; Yao, Min-Szu; Chang, Yue-Chune; Ho, Wei-Pin

    2010-01-01

    The aim of this study was to develop, from patients' characteristics and radiography, a formula reflecting the decision for total knee arthroplasty (TKA) in patients with a painful osteoarthritic knee. We reviewed medical records of 193 consecutive patients who had knee osteoarthritis and underwent primary TKA surgery and 133 consecutive patients with knee osteoarthritis who did not have surgery in one institution during the preceding 5 years. Two skeletal radiologists graded, from 0 to 3, radiographic joint space narrowing (JSN), osteophytes, subchondral sclerosis, and subchondral cysts. The association between the variables and outcome were calculated by the chi-squared test and multivariable logistic regression. Women had more TKAs than men (P = 0.002), and the TKA and non-TKA groups differed in terms of self-care ability (P osteophytes in the medial compartment. The retrospective sensitivity and specificity for patients who underwent TKA surgery were 84% and 83%, respectively. The diagnostic efficacy in retrospect evaluated by a receiver operating characteristic curve was 0.92. A formula reflecting the decision for TKA surgery in patients with a painful osteoarthritic knee has been developed with acceptable diagnostic efficacy obtained retrospectively. The formula should be validated by further study.

  20. Interaction of light with planar lattices of atoms: Reflection, transmission, and cooperative magnetometry

    Science.gov (United States)

    Facchinetti, G.; Ruostekoski, J.

    2018-02-01

    We study strong, light-mediated, resonant dipole-dipole interactions in two-dimensional planar lattices of cold atoms. We provide a detailed analysis for the description of the dipolar point emitter lattice plane as a "superatom" whose response is similar to electromagnetically induced transparency but which exhibits an ultranarrow collective size-dependent subradiant resonance linewidth. The superatom model provides intuitively simple descriptions for the spectral response of the array, including the complete reflection, full transmission, narrow Fano resonances, and asymptotic expressions for the resonance linewidths of the collective eigenmodes. We propose a protocol to transfer almost the entire radiative excitation to a single correlated subradiant eigenmode in a lattice and show that the medium obtained by stacked lattice arrays can form a cooperative magnetometer. Such a magnetometer utilizes similar principles as magnetometers based on the electromagnetically induced transparency. The accuracy of the cooperative magnetometer, however, is not limited by the single-atom resonance linewidth but the much narrower collective linewidth that results from the strong dipole-dipole interactions.

  1. Investigation of polyelectrolytes by total reflection x-ray fluorescence spectrometry

    International Nuclear Information System (INIS)

    Varga, I.; Nagy, M.

    2000-01-01

    Water soluble polyelectrolyte samples containing mono-, bi- and trivalent metal ions were investigated without any pretreatment. Acid digestion of linear polymers may lead to a product insoluble in water so the digestion has to be avoided. The aim of this paper was the determination of analytical characteristics and limitations of the total reflection x-ray fluorescence (TXRF) analysis for poly (vinylalcohol-vinylsulphate) salts and poly (acrylic acid, acrylamide) copolymers containing the following cations: K + , Cs + , Ba 2+ , Cu 2+ and La 3+ . On the basis of our results efficiency of ion-exchange during preparation of polyelectrolytes and stoichiometry of the end-product were determined. TXRF results were compared with data gained by inductively coupled plasma atomic emission spectrometry (ICP-AES) measurements except in the case of Cs + which has poor sensitivity in ICP-AES. Good agreement was found between the results of the two techniques and calculations from titrimetric data. Concentration of Li + and Mg 2+ in polymer samples was measured by ICP-AES. In majority of cases film-like dry residues of aqueous solutions of polyelectrolytes can be characterized by homogeneous spatial distribution of metal ions within the organic matrix. This is because the migration of the ions is hindered during drying process. Determination of metals in polyelectrolyte films by TXRF is quite ideal as model for analysis of plant, animal or human tissues which is a frequent task in environmental and inorganic biomedical analytical chemistry. (author)

  2. Label free imaging of cell-substrate contacts by holographic total internal reflection microscopy.

    Science.gov (United States)

    Mandracchia, Biagio; Gennari, Oriella; Marchesano, Valentina; Paturzo, Melania; Ferraro, Pietro

    2017-09-01

    The study of cell adhesion contacts is pivotal to understand cell mechanics and interaction at substrates or chemical and physical stimuli. We designed and built a HoloTIR microscope for label-free quantitative phase imaging of total internal reflection. Here we show for the first time that HoloTIR is a good choice for label-free study of focal contacts and of cell/substrate interaction as its sensitivity is enhanced in comparison with standard TIR microscopy. Finally, the simplicity of implementation and relative low cost, due to the requirement of less optical components, make HoloTIR a reasonable alternative, or even an addition, to TIRF microscopy for mapping cell/substratum topography. As a proof of concept, we studied the formation of focal contacts of fibroblasts on three substrates with different levels of affinity for cell adhesion. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Colouration of medieval glass bracelets studied by total reflection x-ray fluorescence analysis

    International Nuclear Information System (INIS)

    Detcheva, Albena; Velinova, Ralitsa; Ivanova, Elisaveta; Jordanov, Juri; Karadjov, Metody

    2014-01-01

    The contents of 3d-transition metals (Ti, V, Cr, Mn, Fe, Co, Ni, Cu and Zn) in fragments of medieval glass bracelets, found in the necropolis of Stambolovo and the castle of Mezek, Bulgaria, were determined by total reflection X-ray fluorescence (TXRF) analysis using gallium as internal standard. The samples were analysed as slurries in Triton X 114. The experimental parameters: grain size of the glass sample, concentrations of glass sample, Triton X114 and internal standard in the slurry, volume of the slurry aliquot taken for analysis, as well as the excitation time, were optimised. For method validation the certified reference material BAM-S005 Type A soda-lime glass was used. It was proven that the elements Co, Mn and Fe are responsible for colour generation in the investigated glass samples. The precision of the determinations is characterised by an RSD in the range 3–11%

  4. Combining total internal reflection sum frequency spectroscopy spectral imaging and confocal fluorescence microscopy.

    Science.gov (United States)

    Allgeyer, Edward S; Sterling, Sarah M; Gunewardene, Mudalige S; Hess, Samuel T; Neivandt, David J; Mason, Michael D

    2015-01-27

    Understanding surface and interfacial lateral organization in material and biological systems is critical in nearly every field of science. The continued development of tools and techniques viable for elucidation of interfacial and surface information is therefore necessary to address new questions and further current investigations. Sum frequency spectroscopy (SFS) is a label-free, nonlinear optical technique with inherent surface specificity that can yield critical organizational information on interfacial species. Unfortunately, SFS provides no spatial information on a surface; small scale heterogeneities that may exist are averaged over the large areas typically probed. Over the past decade, this has begun to be addressed with the advent of SFS microscopy. Here we detail the construction and function of a total internal reflection (TIR) SFS spectral and confocal fluorescence imaging microscope directly amenable to surface investigations. This instrument combines, for the first time, sample scanning TIR-SFS imaging with confocal fluorescence microscopy.

  5. BRDF invariant stereo using light transport constancy.

    Science.gov (United States)

    Wang, Liang; Yang, Ruigang; Davis, James E

    2007-09-01

    Nearly all existing methods for stereo reconstruction assume that scene reflectance is Lambertian and make use of brightness constancy as a matching invariant. We introduce a new invariant for stereo reconstruction called light transport constancy (LTC), which allows completely arbitrary scene reflectance (bidirectional reflectance distribution functions (BRDFs)). This invariant can be used to formulate a rank constraint on multiview stereo matching when the scene is observed by several lighting configurations in which only the lighting intensity varies. In addition, we show that this multiview constraint can be used with as few as two cameras and two lighting configurations. Unlike previous methods for BRDF invariant stereo, LTC does not require precisely configured or calibrated light sources or calibration objects in the scene. Importantly, the new constraint can be used to provide BRDF invariance to any existing stereo method whenever appropriate lighting variation is available.

  6. Reflection and Refraction of Light in Absorbing Media

    Science.gov (United States)

    Katsumata, Koichi; Sasaki, Shosuke

    2018-05-01

    The results of a rigorous calculation of optical phenomena in absorbing media based on Maxwell's equations are reported. In the case of an absorbing dielectric, we assume a complex dielectric constant. We find an expression for the angle of refraction as a function of the incident angle and the real and imaginary parts of the complex dielectric constant, all of which are real. The amplitudes of the reflected and transmitted waves are calculated on the same footing. These amplitudes are shown to be complex, from which we deduce the magnitude and phase change of the reflection and transmission coefficients. The same argument applies to an absorbing magnetic material if we replace the complex dielectric constant by a complex magnetic permeability.

  7. Modelling of solar cells with down-conversion of high energy photons, anti-reflection coatings and light trapping

    International Nuclear Information System (INIS)

    Vos, Alexis de; Szymanska, Aleksandra; Badescu, Viorel

    2009-01-01

    In classical solar cells, each absorbed photon gives rise to one electron-hole pair, irrespective of the photon energy. By applying an appropriate photoluminescent layer in front of the solar cell semiconductor, one can convert one high energy photon into two low energy photons (so-called down-conversion). In the present study, we do not consider photoluminescent layers that merely shift down photon energies (without enhancing the number of photons). In principle, these two photons can then generate two electron-hole pairs in the solar cell, thus increasing the efficiency of the device. However, the two photons emitted by the converter, are not necessarily emitted in the direction of the semiconductor: they can also be emitted in the direction 'back to the sun'. As most semiconductors have a high refractive index, in case the luminescent material has a low refractive index, more than half of the photoluminescence emission is lost in the sun direction, resulting in a net loss of light current generated by the solar cell instead of an increase. On the other hand, a high refractive index of the conversion layer (e.g. equal to the solar cell refractive index) will lead to a bad optical coupling with the air and a good optical coupling with the semiconductor, and therefore, more than 50% of the emitted low energy photons will actually reach the solar cell. However, in the latter case, many solar photons do not reach the converter in the first place because of reflection at the air-converter interface. As a result, it turns out that, in the absence of any anti-reflection coating, a refractive index n 2 of the converting layer in the range between n 1 1/2 and n 1 is optimal, where n 1 is the refractive index of the solar cell material. If, however, an anti-reflection coating is applied between air and the converter, the best choice for n 2 is n 1 . Finally, if two anti-reflection coatings are applied (the former between air and the converter, the latter between the

  8. Unusual development of light-reflecting pigment cells in intact and regenerating tail in the periodic albino mutant of Xenopus laevis.

    Science.gov (United States)

    Fukuzawa, Toshihiko

    2010-10-01

    Unusual light-reflecting pigment cells, "white pigment cells", specifically appear in the periodic albino mutant (a(p) /a(p)) of Xenopus laevis and localize in the same place where melanophores normally differentiate in the wild-type. The mechanism responsible for the development of unusual pigment cells is unclear. In this study, white pigment cells in the periodic albino were compared with melanophores in the wild-type, using a cell culture system and a tail-regenerating system. Observations of both intact and cultured cells demonstrate that white pigment cells are unique in (1) showing characteristics of melanophore precursors at various stages of development, (2) accumulating reflecting platelets characteristic of iridophores, and (3) exhibiting pigment dispersion in response to α-melanocyte stimulating hormone (α-MSH) in the same way that melanophores do. When a tadpole tail is amputated, a functionally competent new tail is regenerated. White pigment cells appear in the mutant regenerating tail, whereas melanophores differentiate in the wild-type regenerating tail. White pigment cells in the mutant regenerating tail are essentially similar to melanophores in the wild-type regenerating tail with respect to their localization, number, and response to α-MSH. In addition to white pigment cells, iridophores which are never present in the intact tadpole tail appear specifically in the somites near the amputation level in the mutant regenerating tail. Iridophores are distinct from white pigment cells in size, shape, blue light-induced fluorescence, and response to α-MSH. These findings strongly suggest that white pigment cells in the mutant arise from melanophore precursors and accumulate reflecting platelets characteristic of iridophores.

  9. Total reflection X-ray fluorescence as a tool for food screening

    Science.gov (United States)

    Borgese, Laura; Bilo, Fabjola; Dalipi, Rogerta; Bontempi, Elza; Depero, Laura E.

    2015-11-01

    This review provides a comprehensive overview of the applications of total reflection X-ray fluorescence (TXRF) in the field of food analysis. Elemental composition of food is of great importance, since food is the main source of essential, major and trace elements for animals and humans. Some potentially toxic elements, dangerous for human health may contaminate food, entering the food chain from the environment, processing, and storage. For this reason the elemental analysis of food is fundamental for safety assessment. Fast and sensitive analytical techniques, able to detect major and trace elements, are required as a result of the increasing demand on multi-elemental information and product screening. TXRF is suitable for elemental analysis of food, since it provides simultaneous multi-elemental identification in a wide dynamic range of concentrations. Several different matrices may be analyzed obtaining results with a good precision and accuracy. In this review, the most recent literature about the use of TXRF for the analysis of food is reported. The focus is placed on the applications within food quality monitoring of drinks, beverages, vegetables, fruits, cereals, animal derivatives and dietary supplements. Furthermore, this paper provides a critical outlook on the developments required to transfer these methods from research to the industrial and analytical laboratories contexts.

  10. Matrix effect on the detection limit and accuracy in total reflection X-ray fluorescence analysis of trace elements in environmental and biological samples

    International Nuclear Information System (INIS)

    Karjou, J.

    2007-01-01

    The effect of matrix contents on the detection limit of total reflection X-ray fluorescence analysis was experimentally investigated using a set of multielement standard solutions (500 ng/mL of each element) in variable concentrations of NH 4 NO 3 . It was found that high matrix concentration, i.e. 0.1-10% NH 4 NO 3 , had a strong effect on the detection limits for all investigated elements, whereas no effect was observed at lower matrix concentration, i.e. 0-0.1% NH 4 NO 3 . The effect of soil and blood sample masses on the detection limit was also studied. The results showed decreasing the detection limit (in concentration unit, μg/g) with increasing the sample mass. However, the detection limit increased (in mass unit, ng) with increasing sample mass. The optimal blood sample mass of ca. 200 μg was sufficient to improve the detection limit of Se determination by total reflection X-ray fluorescence. The capability of total reflection X-ray fluorescence to analyze different kinds of samples was discussed with respect to the accuracy and detection limits based on certified and reference materials. Direct analysis of unknown water samples from several sources was also presented in this work

  11. REFLECTION AND REFRACTION, VOLUME 2.

    Science.gov (United States)

    KLAUS, DAVID J.; AND OTHERS

    THIS VOLUME 2 OF A TWO-VOLUME SET PROVIDES AUTOINSTRUCTION IN PHYSICS. THE UNITS COVERED IN THIS VOLUME ARE (1) REFLECTION OF LIGHT, (2) PHOTOMETRY, (3) POLARIZATION, (4) REFRACTION OF LIGHT, (5) SNELL'S LAW, (6) LENSES, FOCUS, AND FOCAL POINTS, (7) IMAGE FORMATION, AND (8) ABERRATIONS, THE EYE, AND MAGNIFICATION. THE INTRODUCTION AND UNITS ON…

  12. Energy-analysis of the total nuclear energy cycle based on light water reactors

    International Nuclear Information System (INIS)

    Kistemaker, J.

    1975-01-01

    The energy economy of the total nuclear energy cycle is investigated. Attention is paid to the importance of fossil fuel saving by using nuclear energy. The energy analysis is based on the construction and operation of power plants with an electric output of 1000MWe. Light water moderated reactors with a 2.7 - 3.2% enriched uranium core are considered. Additionally, the whole fuel cycle including ore winning and refining, enrichment and fuel element manufacturing and reprocessing has been taken into account. Neither radioactive waste storage problems nor safety problems related to the nuclear energy cycle and safeguarding have been dealt with, as exhaustive treatments can be found elswhere

  13. Characterization of Printing Inks Using DART-Q-TOF-MS and Attenuated Total Reflectance (ATR) FTIR.

    Science.gov (United States)

    Williamson, Rhett; Raeva, Anna; Almirall, Jose R

    2016-05-01

    The rise in improved and widely accessible printing technology has resulted in an interest to develop rapid and minimally destructive chemical analytical techniques that can characterize printing inks for forensic document analysis. Chemical characterization of printing inks allows for both discrimination of inks originating from different sources and the association of inks originating from the same source. Direct analysis in real-time mass spectrometry (DART-MS) and attenuated total reflectance Fourier transform infrared spectroscopy (ATR-FTIR) were used in tandem to analyze four different classes of printing inks: inkjets, toners, offset, and intaglio. A total of 319 samples or ~ 80 samples from each class were analyzed directly on a paper substrate using the two methods. DART-MS was found to characterize the semi-volatile polymeric vehicle components, while ATR-FTIR provided chemical information associated with the bulk components of these inks. Complimentary data results in improved discrimination when both techniques are used in succession resulting in >96% discrimination for all toners, 95% for all inkjets, >92% for all offset, and >54% for all intaglio inks. © 2016 American Academy of Forensic Sciences.

  14. CO 2 Capture Capacity and Swelling Measurements of Liquid-like Nanoparticle Organic Hybrid Materials via Attenuated Total Reflectance Fourier Transform Infrared Spectroscopy

    KAUST Repository

    Park, Youngjune; Shin, Dolly; Jang, Young Nam; Park, Ah-Hyung Alissa

    2012-01-01

    attenuated total reflectance (ATR) Fourier transform infrared (FT-IR) spectroscopy. Simultaneous measurements of CO 2 capture capacity and swelling behaviors of polyetheramine (Jeffamine M-2070) and its corresponding NOHMs (NOHM-I-PE2070) were reported

  15. Playing with Light: Adventures in Optics and Spectroscopy for Honors and Majors General Chemistry

    Science.gov (United States)

    van Staveren, Marie N.; Edwards, Kimberly D.; Apkarian, V. A.

    2012-01-01

    A lab was developed for use in an undergraduate honors and majors general chemistry laboratory to introduce students to optics, spectroscopy, and the underlying principles of quantum mechanics. This lab includes four mini-experiments exploring total internal reflection, the tunneling of light, spectra of sparklers and colored candles, and emission…

  16. Multi-layered fabrication of large area PDMS flexible optical light guide sheets

    Science.gov (United States)

    Green, Robert; Knopf, George K.; Bordatchev, Evgueni V.

    2017-02-01

    Large area polydimethylsiloxane (PDMS) flexible optical light guide sheets can be used to create a variety of passive light harvesting and illumination systems for wearable technology, advanced indoor lighting, non-planar solar light collectors, customized signature lighting, and enhanced safety illumination for motorized vehicles. These thin optically transparent micro-patterned polymer sheets can be draped over a flat or arbitrarily curved surface. The light guiding behavior of the optical light guides depends on the geometry and spatial distribution of micro-optical structures, thickness and shape of the flexible sheet, refractive indices of the constituent layers, and the wavelength of the incident light. A scalable fabrication method that combines soft-lithography, closed thin cavity molding, partial curing, and centrifugal casting is described in this paper for building thin large area multi-layered PDMS optical light guide sheets. The proposed fabrication methodology enables the of internal micro-optical structures (MOSs) in the monolithic PDMS light guide by building the optical system layer-by-layer. Each PDMS layer in the optical light guide can have the similar, or a slightly different, indices of refraction that permit total internal reflection within the optical sheet. The individual molded layers may also be defect free or micro-patterned with microlens or reflecting micro-features. In addition, the bond between adjacent layers is ensured because each layer is only partially cured before the next functional layer is added. To illustrate the scalable build-by-layers fabrication method a three-layer mechanically flexible illuminator with an embedded LED strip is constructed and demonstrated.

  17. Reflective properties of domestic fowl (Gallus g. domesticus), the fabric of their housing and the characteristics of the light environment in environmentally controlled poultry houses.

    Science.gov (United States)

    Prescott, N B; Wathes, C M

    1999-05-01

    1. The light intensity and spectral power distribution in 3 broiler and 6 layer houses were sampled and converted to a measure which takes account of the domestic fowl's spectral sensitivity (termed lux corrected). Light intensity was highly variable around the layer houses (mean 33.2, s.d. 37.7 lux (corrected)) and to a lesser extent in the broiler houses (mean 5.2, s.d. 2.2 lux (corrected)). The mean intensities were also very much lower than on a sunny, June day at midday at Silsoe (42,937 lux (corrected)) and of different power distributions. 2. The reflectivity of the plumage of 15 traditional breeds of domestic fowl was surveyed. Most feathers showed a characteristic pattern of reflectivity, increasing either side of a wavelength of lambda = 400 nm. In 13 breeds the tail and wing feathers were darker than the breast and back feathers. Reflectivity at lambda = 700 nm was a good predictor of reflectivity at lambda = 320 nm. Food, bedding, wood and skin all had similar reflectivities to feathers. Metal, plastic and rubber all had more constant reflectivities across the spectrum. 3. The reflectivities of the fresh, feathered carcases of 3 male broilers (Cobb) and 3 layer hens (ISA Brown) were measured. There were small changes in hue and saturation within and between individual carcases, even for the apparently white broiler chickens. 4. Photographs were taken, with and without a UV(A)-only pass filter, of a broiler cock (Cobb), layer hen (ISA Brown) and cock jungle fowl. No additional patternation was evident in the UV(A)-only photographs and the jungle fowl lost most of its ornamentation. The texture of bare skin was enhanced in the UV(A)-only photographs. 5. The implications of these results for poultry behaviour are discussed.

  18. Imaging Early Steps of Sindbis Virus Infection by Total Internal Reflection Fluorescence Microscopy

    Directory of Open Access Journals (Sweden)

    Youling Gu

    2011-01-01

    Full Text Available Sindbis virus (SINV is an alphavirus that has a broad host range and has been widely used as a vector for recombinant gene transduction, DNA-based vaccine production, and oncolytic cancer therapy. The mechanism of SINV entry into host cells has yet to be fully understood. In this paper, we used single virus tracking under total internal reflection fluorescence microscopy (TIRFM to investigate SINV attachment to cell surface. Biotinylated viral particles were labeled with quantum dots, which retained viral viability and infectivity. By time-lapse imaging, we showed that the SINV exhibited a heterogeneous dynamics on the surface of the host cells. Analysis of SINV motility demonstrated a two-step attachment reaction. Moreover, dual color TIRFM of GFP-Rab5 and SINV suggested that the virus was targeted to the early endosomes after endocytosis. These findings demonstrate the utility of quantum dot labeling in studying the early steps and behavior of SINV infection.

  19. Watch your step! A frustrated total internal reflection approach to forensic footwear imaging.

    Science.gov (United States)

    Needham, J A; Sharp, J S

    2016-02-16

    Forensic image retrieval and processing are vital tools in the fight against crime e.g. during fingerprint capture. However, despite recent advances in machine vision technology and image processing techniques (and contrary to the claims of popular fiction) forensic image retrieval is still widely being performed using outdated practices involving inkpads and paper. Ongoing changes in government policy, increasing crime rates and the reduction of forensic service budgets increasingly require that evidence be gathered and processed more rapidly and efficiently. A consequence of this is that new, low-cost imaging technologies are required to simultaneously increase the quality and throughput of the processing of evidence. This is particularly true in the burgeoning field of forensic footwear analysis, where images of shoe prints are being used to link individuals to crime scenes. Here we describe one such approach based upon frustrated total internal reflection imaging that can be used to acquire images of regions where shoes contact rigid surfaces.

  20. Watch your step! A frustrated total internal reflection approach to forensic footwear imaging

    Science.gov (United States)

    Needham, J. A.; Sharp, J. S.

    2016-02-01

    Forensic image retrieval and processing are vital tools in the fight against crime e.g. during fingerprint capture. However, despite recent advances in machine vision technology and image processing techniques (and contrary to the claims of popular fiction) forensic image retrieval is still widely being performed using outdated practices involving inkpads and paper. Ongoing changes in government policy, increasing crime rates and the reduction of forensic service budgets increasingly require that evidence be gathered and processed more rapidly and efficiently. A consequence of this is that new, low-cost imaging technologies are required to simultaneously increase the quality and throughput of the processing of evidence. This is particularly true in the burgeoning field of forensic footwear analysis, where images of shoe prints are being used to link individuals to crime scenes. Here we describe one such approach based upon frustrated total internal reflection imaging that can be used to acquire images of regions where shoes contact rigid surfaces.

  1. Attenuated total reflection UV spectroscopy for simultaneous analysis of alkali, sulphide and dissolved lignin in pulping liquors

    International Nuclear Information System (INIS)

    Chai, X.S.; Zhu, J.Y.; Luo, Q.; Li, J.

    2003-01-01

    This study experimentally demonstrated attenuated total reflection (ATR) ultraviolet (UV) spectroscopy for rapid and simultaneous determination of the concentrations of hydroxide, sulphide and dissolved lignin in kraft pulping liquors. A multivariate partial least squares fitting procedure (using commercially available software) was employed to obtain the species concentrations from the measured absorption spectra of the pulping liquors. Good agreements between ATR-UV measured species concentrations and those obtained by reference methods (titration for hydroxide and sulphide and conventional UV absorption for dissolved lignin) were achieved. (author)

  2. A small-displacement sensor using total internal reflection theory and surface plasmon resonance technology for heterodyne interferometry.

    Science.gov (United States)

    Wang, Shinn-Fwu

    2009-01-01

    A small-displacement sensor based on total-internal reflection theory and surface plasmon resonance technology is proposed for use in heterodyne interferometry. A small displacement can be obtained simply by measuring the variation in phase difference between s- and p-polarization states with the small-displacement sensor. The theoretical displacement resolution of the small-displacement sensor can reach 0.45 nm. The sensor has some additional advantages, e.g., a simple optical setup, high resolution, high sensitivity and rapid measurement. Its feasibility is also demonstrated.

  3. DIRC, the internally reflecting ring imaging Cherenkov detector for BABAR

    International Nuclear Information System (INIS)

    Adam, I.; Aston, D.

    1997-11-01

    The DIRC is a new type of Cherenkov imaging device that will be used for the first time in the BABAR detector at the asymmetric B-factory, PEP-II. It is based on total internal reflection and uses long, rectangular bars made from synthetic fused silica as Cherenkov radiator and light guide. The principles of the DIRC ring imaging Cherenkov technique are explained and results from the prototype program are presented. Its choice for the BABAR detector particle identification system is motivated, followed by a discussion of the quartz radiator properties and the detector design

  4. Transmission versus reflectance spectroscopy for quantitation

    Science.gov (United States)

    Gardner, Craig M.

    2018-01-01

    The objective of this work was to compare the accuracy of analyte concentration estimation when using transmission versus diffuse reflectance spectroscopy of a scattering medium. Monte Carlo ray tracing of light through the medium was used in conjunction with pure component absorption spectra and Beer-Lambert absorption along each ray's pathlength to generate matched sets of pseudoabsorbance spectra, containing water and six analytes present in skin. PLS regression models revealed an improvement in accuracy when using transmission compared to reflectance for a range of medium thicknesses and instrument noise levels. An analytical expression revealed the source of the accuracy degradation with reflectance was due both to the reduced collection efficiency for a fixed instrument etendue and to the broad pathlength distribution that detected light travels in the medium before exiting from the incident side.

  5. Wing Scale Orientation Alters Reflection Directions in the Green Hairstreak Chrysozephyrus smaragdinus (Lycaenidae; Lepidoptera).

    Science.gov (United States)

    Imafuku, Michio; Ogihara, Naomichi

    2016-12-01

    There have been only a few reports on the directional reflection of light by butterfly wings. Here, we systematically investigated this phenomenon in a lycaenid butterfly, Chrysozephyrus smaragdinus,in which males have bright green wings based on structural coloration. We used a device that measures intensities of light in hemispherical space by vertical shifting of a sensor and horizontal rotation of the stage carrying the wing, which is illuminated from the top, to determine the direction of light reflected by the fore- and hindwings. The orientation and curvature of wing scales were also examined microscopically. The forewing of this species reflected light shone from the top largely forward, whereas the hindwing reflected it slightly forward. This difference was attributed to the tilt angles of the wing scales. Light reflection by the forewing was relatively weak, and widely scattered, whereas that by the hindwing was rather concentrated, resulting in higher reflectance. This difference was attributed to difference in the curvature of the wing scales on the two wings.

  6. Simple method for measuring reflectance of optical coatings

    International Nuclear Information System (INIS)

    Wen Gui Wang; Yi Sheng Chen

    1995-01-01

    The quality of optical coatings has an important effect on the performance of optical instrument. The last few years, the requirements for super low loss dielectric mirror coatings used in low gain laser systems such as free electron laser and the ring laser etc., have given an impetus to the development of the technology of precise reflectance measurement of optical coatings. A reliable and workable technique is to measure the light intensity decay time of optical resonant cavity. This paper describes a measuring method which is dependent on direct measurement of the light intensity decay time of a resonant cavity comprised of low loss optical components. According to the evolution of a luminous flux stored inside the cavity, this method guarantees not only a quick and precise reflectance measurements of low loss highly reflecting mirror coatings but also transmittance measurements of low loss antireflection coatings and is especially effective with super los loss highly reflecting mirror. From the round-trip path length of the cavity and the speed of light, the light intensity exponential decay time of an optical cavity is easy to obtain and the cavity losses can be deduced. An optical reflectance of low loss highly mirror coatings and antireflection coatings is precisely measured as well. This is highly significant for the discrimination of the coating surface characteristics, the improvement of the performance of optical instrument and the development of high technology

  7. Analytical characterization of artists' pigments used in old and modern paintings by total-reflection x-ray fluorescence

    International Nuclear Information System (INIS)

    Klockenkaemper, R.; Bohlen, A. von; Moens, L.; Devos, W.

    1993-01-01

    The analytical characterization of artists' pigments is a most helpful tool for art history, conservation and restoration of paintings. A very gentle method of ultra-microsampling was developed that is especially applicable to paintings under restoration. It provides a sample mass of about 1 μg and is virtually non-destructive. This minute amount is sufficient for total-reflection X-ray fluorescence (TXRF) to determine most of those elements building inorganic pigments. The convenient and fast method was applied to oil paintings. Various pigments were identified and their mixing proportion was determined even quantitatively. (author)

  8. Determination of solid surface composition by the X-ray fluorescence method under total external reflection with angular scanning

    International Nuclear Information System (INIS)

    Krasnolutskij, V.P.

    2000-01-01

    Possibilities of determination of composition of surface layers by X-ray fluorescence analysis under total reflection of incident radiation with angular scanning of a target are investigated. For the case of the GaAs target it is shown that the sensibility of this method is sufficient for a control of element composition in layer of thickness 1 nm. A simple method for solution of inverse task of analysis of a two component medium is considered [ru

  9. Dynamical characteristics of an electromagnetic field under conditions of total reflection

    Science.gov (United States)

    Bekshaev, Aleksandr Ya

    2018-04-01

    The dynamical characteristics of electromagnetic fields include energy, momentum, angular momentum (spin) and helicity. We analyze their spatial distributions near the planar interface between two transparent and non-dispersive media, when the incident monochromatic plane wave with arbitrary polarization is totally reflected, and an evanescent wave is formed in the medium with lower optical density. Based on the recent arguments in favor of the Minkowski definition of the electromagnetic momentum in a material medium (Philbin 2011 Phys. Rev. A 83 013823; Philbin and Allanson 2012 86 055802; Bliokh et al 2017 Phys. Rev. Lett. 119 073901), we derive the explicit expressions for the dynamical characteristics in both media, with special attention to their behavior at the interface. In particular, the ‘extraordinary’ spin and momentum components orthogonal to the plane of incidence are described, and a canonical (spin-orbital) momentum decomposition is performed that contains no singular terms. The field energy, helicity, the spin momentum and orbital momentum components are everywhere regular but experience discontinuities at the interface; the spin components parallel to the interface appear to be continuous, which testifies to the consistency of the adopted Minkowski picture. The results supply a meaningful example of the electromagnetic momentum decomposition, with separation of spatial and polarization degrees of freedom, in inhomogeneous media, and can be used in engineering the structured fields designed for optical sorting, dispatching and micromanipulation.

  10. Analysis of total oil and fatty acids composition by near infrared reflectance spectroscopy in edible nuts

    Science.gov (United States)

    Kandala, Chari V.; Sundaram, Jaya

    2014-10-01

    Near Infrared (NIR) Reflectance spectroscopy has established itself as an important tool in quantifying water and oil present in various food materials. It is rapid and nondestructive, easier to use, and does not require processing the samples with corrosive chemicals that would render them non-edible. Earlier, the samples had to be ground into powder form before making any measurements. With the development of new soft ware packages, NIR techniques could now be used in the analysis of intact grain and nuts. While most of the commercial instruments presently available work well with small grain size materials such as wheat and corn, the method present here is suitable for large kernel size products such as shelled or in-shell peanuts. Absorbance spectra were collected from 400 nm to 2500 nm using a NIR instrument. Average values of total oil contents (TOC) of peanut samples were determined by standard extraction methods, and fatty acids were determined using gas chromatography. Partial least square (PLS) analysis was performed on the calibration set of absorption spectra, and models were developed for prediction of total oil and fatty acids. The best model was selected based on the coefficient of determination (R2), Standard error of prediction (SEP) and residual percent deviation (RPD) values. Peanut samples analyzed showed RPD values greater than 5.0 for both absorbance and reflectance models and thus could be used for quality control and analysis. Ability to rapidly and nondestructively measure the TOC, and analyze the fatty acid composition, will be immensely useful in peanut varietal improvement as well as in the grading process of grain and nuts.

  11. Temporal reflectance from a light pulse irradiated medium embedded with highly scattering cores

    International Nuclear Information System (INIS)

    Hsu Peifeng; Lu Xiaodong

    2007-01-01

    This paper presents a new approach to utilize ultrashort pulsed laser for optical diagnostics with numerical simulations. The method is based on the use of ultrafast pulses with a pulsewidth selected according to the probed medium's radiative property and/or size. Our previous work in nonhomogeneous media has shown that the resulting time-resolved reflectance signal will have a unique characteristic: it will show a direct correlation of ballistic photon travel time and interface location, which is in between different layers or nonhomogeneous regions. The premise is based on utilizing the medium's structural information carried by the ballistic and snake photons without being masked by the diffuse photons. In this study, the space-time correlation is further explored in the case of minimally scattered photons from a large scattering coefficient core region embedded within a less-scattering medium. Time-resolved reflectance signals of the single scattering core and multiple scattering cores within a three-dimensional medium demonstrate the concept and illustrate the additional effect due to the scattered photons from the core region. A unique temporal signal profile's correlation at various detector positions with respect to the scattering core is explained in detail. The result has important implications. This approach will lead to a much simpler and more precise determination of the probed medium's composition or structure. Due to the large computational requirement to obtain the physical details of the light pulse propagation inside highly scattering multi-dimensional media, the reverse Monte-Carlo method is used. The potential applications of the method include non-destructive diagnostics, optical imaging, and remote sensing of underwater objects

  12. Implementation of light extraction improvements of GaN-based light-emitting diodes with specific textured sidewalls

    Science.gov (United States)

    Chen, Chun-Yen; Chen, Wei-Cheng; Chang, Ching-Hong; Lee, Yu-Lin; Liu, Wen-Chau

    2018-05-01

    Textured-sidewall GaN-based light-emitting diodes (LEDs) with various sidewall angles (15-90°) and convex or concave sidewalls prepared using an inductively-coupled-plasma approach are comprehensively fabricated and studied. The device with 45° sidewalls (Device F) and that with convex sidewalls (Device B) show significant improvements in optical properties. Experiments show that, at an injection current of 350 mA, the light output power, external quantum efficiency, wall-plug efficiency, and luminous flux of Device F (Device B) are greatly improved by 18.3% (18.2%), 18.2% (18.2%), 17.3% (19.8%), and 16.6% (18.4%), respectively, compared to those of a conventional LED with flat sidewalls. In addition, negligible degradation in electrical properties is found. The enhanced optical performance is mainly attributed to increased light extraction in the horizontal direction due to a significant reduction in total internal reflection at the textured sidewalls. Therefore, the reported specific textured-sidewall structures (Devices B and F) are promising for high-power GaN-based LED applications.

  13. Neurofilament light antibodies in serum reflect response to natalizumab treatment in multiple sclerosis.

    Science.gov (United States)

    Amor, Sandra; van der Star, Baukje J; Bosca, Isabel; Raffel, Joel; Gnanapavan, Sharmilee; Watchorn, Jonathan; Kuhle, Jens; Giovannoni, Gavin; Baker, David; Malaspina, Andrea; Puentes, Fabiola

    2014-09-01

    Increased levels of antibodies to neurofilament light protein (NF-L) in biological fluids have been found to reflect neuroinflammatory responses and neurodegeneration in multiple sclerosis (MS). To evaluate whether levels of serum antibodies against NF-L correlate with clinical variants and treatment response in MS. The autoantibody reactivity to NF-L protein was tested in serum samples from patients with relapsing-remitting MS (RRMS) (n=22) and secondary progressive MS (SPMS) (n=26). Two other cohorts of RRMS patients under treatment with natalizumab were analysed cross-sectionally (n=16) and longitudinally (n=24). The follow-up samples were taken at 6, 12, 18 and 24 months after treatment, and the NF-L antibody levels were compared against baseline levels. NF-L antibodies were higher in MS clinical groups than healthy controls and in RRMS compared to SPMS patients (ptreatment compared with baseline measurements (p=0.001). Drug efficacy in MS treatment indicates the potential use of monitoring the content of antibodies against the NF-L chain as a predictive biomarker of treatment response in MS. © The Author(s) 2014.

  14. Simple and rapid quantification of total carotenoids in lyophilized apricots (prunus armeniaca L.) by means of reflectance colorimetry and photoacoustic spectrometry spectroscopy

    NARCIS (Netherlands)

    Doka, O.; Ficzek, G.; Luterotti, S.; Bicanic, D.D.; Spruijt, R.B.; Buijnsters, J.; Vegvari, G.

    2013-01-01

    Photoacoustic spectroscopy (PAS) and reflectance colorimetry are suggested as new tools for the analysis of total carotenoids in lyophilized apricot powders. The data obtained by these two techniques from seven apricot cultivars were compared to those acquired by spectrophotometry and

  15. Surface reflectance drives nest box temperature profiles and thermal suitability for target wildlife.

    Directory of Open Access Journals (Sweden)

    Stephen R Griffiths

    Full Text Available Thermal properties of tree hollows play a major role in survival and reproduction of hollow-dependent fauna. Artificial hollows (nest boxes are increasingly being used to supplement the loss of natural hollows; however, the factors that drive nest box thermal profiles have received surprisingly little attention. We investigated how differences in surface reflectance influenced temperature profiles of nest boxes painted three different colors (dark-green, light-green, and white: total solar reflectance 5.9%, 64.4%, and 90.3% respectively using boxes designed for three groups of mammals: insectivorous bats, marsupial gliders and brushtail possums. Across the three different box designs, dark-green (low reflectance boxes experienced the highest average and maximum daytime temperatures, had the greatest magnitude of variation in daytime temperatures within the box, and were consistently substantially warmer than light-green boxes (medium reflectance, white boxes (high reflectance, and ambient air temperatures. Results from biophysical model simulations demonstrated that variation in diurnal temperature profiles generated by painting boxes either high or low reflectance colors could have significant ecophysiological consequences for animals occupying boxes, with animals in dark-green boxes at high risk of acute heat-stress and dehydration during extreme heat events. Conversely in cold weather, our modelling indicated that there are higher cumulative energy costs for mammals, particularly smaller animals, occupying light-green boxes. Given their widespread use as a conservation tool, we suggest that before boxes are installed, consideration should be given to the effect of color on nest box temperature profiles, and the resultant thermal suitability of boxes for wildlife, particularly during extremes in weather. Managers of nest box programs should consider using several different colors and installing boxes across a range of both orientations and

  16. Neutron reflection effect on total absorption detector method used in SWINPC neutron multiplication experiment for beryllium

    International Nuclear Information System (INIS)

    Tian Dongfeng; Ho Yukun; Yang Fujia

    2001-01-01

    The SWINPC integral experiment on neutron multiplication in bulk beryllium showed that there were marked discrepancies between experimental data and calculated values with the ENDF/B-VI data. The calculated values become higher than experimental ones as the sample thickness increases. Several works had been devoted to find problems existing in the experiment. This paper discusses the neutron reflection effect on the total absorption detector method which was used in the experiment to measure the neutron leakage from samples. One systematic correction is suggested to make the experimental values agree with the calculated ones with the ENDF/B-VI data within experimental errors. (author)

  17. FACT light collection - solid light concentrators in Cherenkov Astronomy

    Energy Technology Data Exchange (ETDEWEB)

    Braun, Isabel [ETH Zurich, Institute for Particle Physics, CH-8093 Zurich (Switzerland); Collaboration: FACT-Collaboration

    2011-07-01

    Pixelized cameras of Imaging Atmospheric Cherenkov Telescopes use hollow light guides with reflective surfaces based on the Winston cone design. These cones minimize insensitive spaces between the photo sensors and shield the camera from stray background light by limiting the angular acceptance to the primary reflector area. FACT (First G-APD Cherenkov Telescope) will be the first IACT with Geiger-mode avalanche photodiodes as light sensors. Solid light concentrators complementing these sensors will be used instead of hollow Winston cones. We will present simulations and measurements of our light collector design, which was optimized for the requirements of the FACT telescope and detector, and discuss the specific differences to more traditional solutions.

  18. What Is Light?. Students' Reflections on the Wave-Particle Duality of Light and the Nature of Physics

    Science.gov (United States)

    Henriksen, Ellen Karoline; Angell, Carl; Vistnes, Arnt Inge; Bungum, Berit

    2018-03-01

    Quantum physics describes light as having both particle and wave properties; however, there is no consensus about how to interpret this duality on an ontological level. This article explores how pre-university physics students, while working with learning material focusing on historical-philosophical aspects of quantum physics, interpreted the wave-particle duality of light and which views they expressed on the nature of physics. A thematic analysis was performed on 133 written responses about the nature of light, given in the beginning of the teaching sequence, and 55 audio-recorded small-group discussions addressing the wave-particle duality, given later in the sequence. Most students initially expressed a wave and particle view of light, but some of these gave an "uncritical duality description", accepting without question the two ontologically different descriptions of light. In the small-group discussions, students expressed more nuanced views. Many tried to reconcile the two descriptions using semi-classical reasoning; others entered into philosophical discussions about the status of the current scientific description of light and expected science to come up with a better model. Some found the wave description of light particularly challenging and lacked a conception of "what is waving". Many seemed to implicitly take a realist view on the description of physical phenomena, contrary with the Copenhagen interpretation which is prevalent in textbooks. Results are discussed in light of different interpretations of quantum physics, and we conclude by arguing for a historical-philosophical perspective as an entry point for upper secondary physics students to explore the development and interpretation of quantum physical concepts.

  19. Analysis of Electric Field Propagation in Anisotropically Absorbing and Reflecting Waveplates

    Science.gov (United States)

    Carnio, B. N.; Elezzabi, A. Y.

    2018-04-01

    Analytical expressions are derived for half-wave plates (HWPs) and quarter-wave plates (QWPs) based on uniaxial crystals. This general analysis describes the behavior of anisotropically absorbing and reflecting waveplates across the electromagnetic spectrum, which allows for correction to the commonly used equations determined assuming isotropic absorptions and reflections. This analysis is crucial to the design and implementation of HWPs and QWPs in the terahertz regime, where uniaxial crystals used for waveplates are highly birefringent and anisotropically absorbing. The derived HWP equations describe the rotation of linearly polarized light by an arbitrary angle, whereas the QWP analysis focuses on manipulating a linearly polarized electric field to obtain any ellipticity. The HWP and QWP losses are characterized by determining equations for the total electric field magnitude transmitted through these phase-retarding elements.

  20. Quantum correlations induced by multiple scattering of quadrature squeezed light

    DEFF Research Database (Denmark)

    Lodahl, Peter

    2006-01-01

    Propagating quadrature squeezed light through a multiple scattering random medium is found to induce pronounced spatial quantum correlations that have no classical analogue. The correlations are revealed in the number of photons transported through the sample that can be measured from the intensity...... fluctuations of the total transmission or reflection. In contrast, no pronounced spatial quantum correlations appear in the quadrature amplitudes where excess noise above the shot noise level is found....

  1. First Total Reflection X-Ray Fluorescence round-robin test of water samples: Preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Borgese, Laura; Bilo, Fabjola [Chemistry for Technologies Laboratory, University of Brescia, Brescia (Italy); Tsuji, Kouichi [Graduate School of Engineering, Osaka City University, Osaka (Japan); Fernández-Ruiz, Ramón [Servicio Interdepartamental de Investigación (SIdI), Laboratorio de TXRF, Universidad Autónoma de Madrid, Madrid (Spain); Margui, Eva [Department of Chemistry, University of Girona, Girona (Spain); Streli, Christina [TU Wien, Atominstitut,Radiation Physics, Vienna (Austria); Pepponi, Giancarlo [Fondazione Bruno Kessler, Povo, Trento (Italy); Stosnach, Hagen [Bruker Nano GmbH, Berlin (Germany); Yamada, Takashi [Rigaku Corporation, Takatsuki, Osaka (Japan); Vandenabeele, Peter [Department of Archaeology, Ghent University, Ghent (Belgium); Maina, David M.; Gatari, Michael [Institute of Nuclear Science and Technology, University of Nairobi, Nairobi (Kenya); Shepherd, Keith D.; Towett, Erick K. [World Agroforestry Centre (ICRAF), Nairobi (Kenya); Bennun, Leonardo [Laboratorio de Física Aplicada, Departamento de Física, Universidad de Concepción (Chile); Custo, Graciela; Vasquez, Cristina [Gerencia Química, Laboratorio B025, Centro Atómico Constituyentes, San Martín (Argentina); Depero, Laura E., E-mail: laura.depero@unibs.it [Chemistry for Technologies Laboratory, University of Brescia, Brescia (Italy)

    2014-11-01

    Total Reflection X-Ray Fluorescence (TXRF) is a mature technique to evaluate quantitatively the elemental composition of liquid samples deposited on clean and well polished reflectors. In this paper the results of the first worldwide TXRF round-robin test of water samples, involving 18 laboratories in 10 countries are presented and discussed. The test was performed within the framework of the VAMAS project, interlaboratory comparison of TXRF spectroscopy for environmental analysis, whose aim is to develop guidelines and a standard methodology for biological and environmental analysis by means of the TXRF analytical technique. - Highlights: • The discussion of the first worldwide TXRF round-robin test of water samples (18 laboratories of 10 countries) is reported. • Drinking, waste, and desalinated water samples were tested. • Data dispersion sources were identified: sample concentration, preparation, fitting procedure, and quantification. • The protocol for TXRF analysis of drinking water is proposed.

  2. Controllable transmission and total reflection through an impedance-matched acoustic metasurface

    KAUST Repository

    Mei, Jun

    2014-12-02

    A general design paradigm for a novel type of acoustic metasurface is proposed by introducing periodically repeated supercells on a rigid thin plate, where each supercell contains multiple cut-through slits that are filled with materials possessing different refractive indices but the same impedance as that of the host medium. When the wavelength of the incident wave is smaller than the periodicity, the direction of the transmitted wave with nearly unity transmittance can be chosen by engineering the phase discontinuities along the transverse direction. When the wavelength is larger than the periodicity, even though the metasurface is impedance matched to the host medium, most of the incident energy is reflected back and the remaining portion is converted into a surface-bound mode. We show that both the transmitted wave control and the high reflection with the surface mode excitation can be interpreted by a unified analytic model based on mode-coupling theory. Our general design principle not only supplies the functionalities of reflection-type acoustic metasurfaces, but also exhibits unprecedented flexibility and efficiency in various domains of wave manipulation for possible applications in fields like refracting, collimating, focusing or absorbing wave energy.

  3. Analytical modeling of light transport in scattering materials with strong absorption.

    Science.gov (United States)

    Meretska, M L; Uppu, R; Vissenberg, G; Lagendijk, A; Ijzerman, W L; Vos, W L

    2017-10-02

    We have investigated the transport of light through slabs that both scatter and strongly absorb, a situation that occurs in diverse application fields ranging from biomedical optics, powder technology, to solid-state lighting. In particular, we study the transport of light in the visible wavelength range between 420 and 700 nm through silicone plates filled with YAG:Ce 3+ phosphor particles, that even re-emit absorbed light at different wavelengths. We measure the total transmission, the total reflection, and the ballistic transmission of light through these plates. We obtain average single particle properties namely the scattering cross-section σ s , the absorption cross-section σ a , and the anisotropy factor µ using an analytical approach, namely the P3 approximation to the radiative transfer equation. We verify the extracted transport parameters using Monte-Carlo simulations of the light transport. Our approach fully describes the light propagation in phosphor diffuser plates that are used in white LEDs and that reveal a strong absorption (L/l a > 1) up to L/l a = 4, where L is the slab thickness, l a is the absorption mean free path. In contrast, the widely used diffusion theory fails to describe this parameter range. Our approach is a suitable analytical tool for industry, since it provides a fast yet accurate determination of key transport parameters, and since it introduces predictive power into the design process of white light emitting diodes.

  4. Generation of neutron standing waves at total reflection of polarized neutrons

    International Nuclear Information System (INIS)

    Aksenov, V.L.; Nikitenko, Yu.V.; Kozhevnikov, S.V.; Radu, F.; Kruijs, R.; Rekveldt, M.Th.

    1999-01-01

    The regime of neutron standing waves at reflection of polarized thermal neutrons from the structure glass/Cu (1000 A Angstrom)/Ti (2000 A Angstrom)/Co (60 A Angstrom)/Ti (300 A Angstrom) in a magnetic field directed at an angle to the sample plane is realized. The intensity of neutrons with a particular spin projection on the external magnetic field direction appears to be a periodic function of the neutron wavelength and the glancing angle of the reflected beam. It is shown that the neutron standing wave regime can be a very sensitive method for the determination of changes in the spatial position of magnetic noncollinear layers. (author)

  5. Total Reflection X-ray Fluorescence Analysis (TXRF) using the high flux SAXS camera

    CERN Document Server

    Wobrauschek, P; Pepponi, G; Bergmann, A; Glatter, O

    2002-01-01

    Combining the high photon flux from a rotating anode X-ray tube with an X-ray optical component to focus and monochromatize the X-ray beam is the most promising instrumentation for best detection limits in the modern XRF laboratory. This is realized by using the design of a high flux SAXS camera in combination with a 4 kW high brilliant rotating Cu anode X-ray tube with a graded elliptically bent multilayer and including a new designed module for excitation in total reflection geometry within the beam path. The system can be evacuated thus reducing absorption and scattering of air and removing the argon peak in the spectra. Another novelty is the use of a Peltier cooled drift detector with an energy resolution of 148 eV at 5.9 keV and 5 mm sup 2 area. For Co detection limits of about 300 fg determined by a single element standard have been achieved. Testing a real sample NIST 1643d led to detection limits in the range of 300 ng/l for the medium Z.

  6. Metal ions diffusion through polymeric matrices: A total reflection X-ray fluorescence study

    International Nuclear Information System (INIS)

    Boeykens, S.; Caracciolo, N.; D'Angelo, M.V.; Vazquez, C.

    2006-01-01

    This work proposes the use of X-ray fluorescence with total reflection geometry to explore the metal ions transport in aqueous hydrophilic polymer solutions. It is centered in the study of polymer concentration influence on ion diffusion. This subject is relevant to various and diverse applications, such as drug controlled release, microbiologic corrosion protection and enhanced oil recovery. It is anticipated that diffusion is influenced by various factors in these systems, including those specific to the diffusing species, such as charge, shape, molecular size, and those related to the structural complexity of the matrix as well as any specific interaction between the diffusing species and the matrix. The diffusion of nitrate salts of Ba and Mn (same charge, different hydrodynamic radii) through water-swollen polymeric solutions and gels in the 0.01% to 1% concentration ranges was investigated. The measurements of the metal concentration were performed by TXRF analysis using the scattered radiation by the sample as internal standard. Results are discussed according to different physical models for solute diffusion in polymeric solutions

  7. A method for thickness determination of thin films of amalgamable metals by total-reflection X-ray fluorescence

    International Nuclear Information System (INIS)

    Bennun, L.; Greaves, E.D.; Barros, H.; Diaz-Valdes, J.

    2009-01-01

    A method for thickness determination of thin amalgamable metallic films by total-reflection X-ray fluorescence (TXRF) is presented. The peak's intensity in TXRF spectra are directly related to the surface density of the sample, i.e. to its thickness in a homogeneous film. Performing a traditional TXRF analysis on a thin film of an amalgamated metal, and determining the relative peak intensity of a specific metal line, the layer thickness can be precisely obtained. In the case of gold thickness determination, mercury and gold peaks overlap, hence we have developed a general data processing scheme to achieve the most precise results.

  8. Determinação não destrutiva do nitrogênio total em plantas por espectroscopia de reflectância difusa no infravermelho próximo Non-destructive determination of total nitrogen in plants by diffuse reflectance near infrared spectroscopy

    Directory of Open Access Journals (Sweden)

    Kássio M. G. Lima

    2008-01-01

    Full Text Available Diffuse reflectance near-infrared (DR-NIR spectroscopy associated with partial least squares (PLS multivariate calibration is proposed for a direct, non-destructive, determination of total nitrogen in wheat leaves. The procedure was developed for an Analytical Instrumental Analysis course, carried out at the Institute of Chemistry of the State University of Campinas. The DR-NIR results are in good agreement with those obtained by the Kjeldhal standard procedure, with a relative error of less than ± 3% and the method may be used for teaching purposes as well as for routine analysis.

  9. Recent Developments in Solid-Phase Extraction for Near and Attenuated Total Reflection Infrared Spectroscopic Analysis

    Directory of Open Access Journals (Sweden)

    Christian W. Huck

    2016-05-01

    Full Text Available A review with more than 100 references on the principles and recent developments in the solid-phase extraction (SPE prior and for in situ near and attenuated total reflection (ATR infrared spectroscopic analysis is presented. New materials, chromatographic modalities, experimental setups and configurations are described. Their advantages for fast sample preparation for distinct classes of compounds containing different functional groups in order to enhance selectivity and sensitivity are discussed and compared. This is the first review highlighting both the fundamentals of SPE, near and ATR spectroscopy with a view to real sample applicability and routine analysis. Most of real sample analyses examples are found in environmental research, followed by food- and bioanalysis. In this contribution a comprehensive overview of the most potent SPE-NIR and SPE-ATR approaches is summarized and provided.

  10. Comparison of ultraviolet Bi-directional Reflectance Distribution Function (BRDF) measurements of diffusers used in the calibration of the Total Ozone Mapping Spectrometer (TOMS)

    OpenAIRE

    Butler, J.J.; Park, H.; Barnes, P.Y.; Early, E.A.; Eijk-Olij, C. van; Zoutman, A.E.; Buller-Leeuwen, S. van; Groote Schaarsberg, J.

    2002-01-01

    The measurement and long-term monitoring of global total ozone by ultraviolet albedo measuring satellite instruments require accurate and precise determination of the Bi-directional Reflectance Distribution Function (BRDF) of laboratory-based diffusers used in the pre-launch calibration of those instruments. To assess the ability of laboratories to provide accurate Ultra Violet (UV) diffuse BRDF measurements, a BRDF measurement comparison was initiated by the NASA Total Ozone Mapping Spectrom...

  11. Accessible biometrics: A frustrated total internal reflection approach to imaging fingerprints.

    Science.gov (United States)

    Smith, Nathan D; Sharp, James S

    2017-05-01

    Fingerprints are widely used as a means of identifying persons of interest because of the highly individual nature of the spatial distribution and types of features (or minuta) found on the surface of a finger. This individuality has led to their wide application in the comparison of fingerprints found at crime scenes with those taken from known offenders and suspects in custody. However, despite recent advances in machine vision technology and image processing techniques, fingerprint evidence is still widely being collected using outdated practices involving ink and paper - a process that can be both time consuming and expensive. Reduction of forensic service budgets increasingly requires that evidence be gathered and processed more rapidly and efficiently. However, many of the existing digital fingerprint acquisition devices have proven too expensive to roll out on a large scale. As a result new, low-cost imaging technologies are required to increase the quality and throughput of the processing of fingerprint evidence. Here we describe an inexpensive approach to digital fingerprint acquisition that is based upon frustrated total internal reflection imaging. The quality and resolution of the images produced are shown to be as good as those currently acquired using ink and paper based methods. The same imaging technique is also shown to be capable of imaging powdered fingerprints that have been lifted from a crime scene using adhesive tape or gel lifters. Copyright © 2017 The Chartered Society of Forensic Sciences. Published by Elsevier B.V. All rights reserved.

  12. Exploration of external light trapping for photovoltaic modules

    NARCIS (Netherlands)

    van Dijk, L.; van de Groep, J.; Di Vece, M.; Schropp, R.E.I.

    2016-01-01

    The reflection of incident sunlight by photovoltaic modules prevents them from reaching their theoretical energy conversion limit. We explore the effectiveness of a universal external light trap that can tackle this reflection loss. A unique feature of external light traps is their capability to

  13. Scattering of light keV ions from amorphous and crystalline solid surfaces

    International Nuclear Information System (INIS)

    Robinson, J.E.; Kwok, K.K.; Thompson, D.A.

    1976-01-01

    Total reflection coefficients (R), backscattered energy fractions (γ), and backscattered energy spectra are evaluated using a binary collision Monte Carlo technique for a variety of light ions (H, D, T, He) in the energy range 0.25-8 keV, incident on amorphous targets (C, Fe, Nb). The scattering is also evaluated for H on Nb for a range of incident angles and two electronic stopping values. The average scattered energy per reflected particle and the backscattered energy spectra are found to vary in a universal manner as a function of the reflection coefficient between the Rutherford high energy limit and a low energy multiple collision limit. Single crystal effects are also briefly discussed using a diffusional dechanneling model. (Auth.)

  14. Characterization and classification of spirituous beverages by total reflection x-ray fluorescence

    International Nuclear Information System (INIS)

    Davila, E.G. de; Lue-Meru, M.P.; Capote, T.; Greaves, E.

    2000-01-01

    The total reflection x-ray fluorescence (TXRF) technique was applied for the multi-elemental analysis of spirituous beverages like rum, cocuy (typical spirituous beverage in Venezuela), whiskey and wine, in order to classify the samples by product processing and geographical origin by chemometric analysis. Special attention was paid to the cocuy samples, since there is a lack of quality control of this beverage, mainly due to the home-made product processing. The use of the Compton peak information was evaluated for the determination of organic content in samples. In the specifically case of cocuy samples the Compton peak area was correlated to the ash content for detection of adulteration with sugar syrup. Cocuy samples were also analyzed using gas chromatography, for pH, acidity, ash content and refractometry, in order to develop the recognition pattern. The TXRF analysis was carried out in a Canberra spectrometer, using the K α-line of a Motube, by a direct procedure previously developed. The analysis of the data was done by using principal components analysis and a confidence test. The results show that TXRF and chemometric analysis is a useful tool for quality control of spirituous beverages, not only concerning to metal content, but also in the evaluation of sugar and non volatile organic content. (author)

  15. Characterization and classification of spirituous beverages by total reflection x-ray fluorescence

    Energy Technology Data Exchange (ETDEWEB)

    Davila, E.G. de [Univerisdad Centroccidental Lisandro Alvarado, Decanato de Agronomia, Dpto. de Quimica y Suelos. Nucleo Tarabana, cabudare, Edo. Lara (Venezuela); Lue-Meru, M P; Capote, T [Univerisdad Centroccidental Lisandro Alvarado, Decanato de Agronomia, Dpto. de Quimica y Suelos. Nucleo Tarabana, Cabudare, Edo. Lara (Venezuela); Universidad Simon Bolivar, Dpto. de Quimica, Lab. Espectroscopia Atomica, Sartenejas, Baruta, Edo. Miranda (Venezuela); Greaves, E [Universidad Simon Bolivar, Dpto. de Fisica, Sartenejas, Baruta, Edo. Miranda (Venezuela)

    2000-07-01

    The total reflection x-ray fluorescence (TXRF) technique was applied for the multi-elemental analysis of spirituous beverages like rum, cocuy (typical spirituous beverage in Venezuela), whiskey and wine, in order to classify the samples by product processing and geographical origin by chemometric analysis. Special attention was paid to the cocuy samples, since there is a lack of quality control of this beverage, mainly due to the home-made product processing. The use of the Compton peak information was evaluated for the determination of organic content in samples. In the specifically case of cocuy samples the Compton peak area was correlated to the ash content for detection of adulteration with sugar syrup. Cocuy samples were also analyzed using gas chromatography, for pH, acidity, ash content and refractometry, in order to develop the recognition pattern. The TXRF analysis was carried out in a Canberra spectrometer, using the K {alpha}-line of a Motube, by a direct procedure previously developed. The analysis of the data was done by using principal components analysis and a confidence test. The results show that TXRF and chemometric analysis is a useful tool for quality control of spirituous beverages, not only concerning to metal content, but also in the evaluation of sugar and non volatile organic content. (author)

  16. Continuous-wave spatial quantum correlations of light induced by multiple scattering

    DEFF Research Database (Denmark)

    Smolka, Stephan; Ott, Johan Raunkjær; Huck, Alexander

    2012-01-01

    and reflectance. Utilizing frequency-resolved quantum noise measurements, we observe that the strength of the spatial quantum correlation function can be controlled by changing the quantum state of an incident bright squeezed-light source. Our results are found to be in excellent agreement with the developed......We present theoretical and experimental results on spatial quantum correlations induced by multiple scattering of nonclassical light. A continuous-mode quantum theory is derived that enables determining the spatial quantum correlation function from the fluctuations of the total transmittance...... theory and form a basis for future research on, e. g., quantum interference of multiple quantum states in a multiple scattering medium....

  17. Sunscope natural light systems : tubular skylights

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2010-07-01

    This brochure described a tubular skylight designed by Sunscope Natural Light Systems. The Sunscope is a super-reflective light system in which daylight is reflected down a cylinder to a translucent ceiling fixture that diffuses natural light throughout the room in which it is placed. The Sunscope requires no structure changes, is installed in less than 3 hours, and requires no drywall repairs or repainting. The system eliminates the need for daytime electric lighting, and causes no winter heat losses or summer heat gains. Available in 3 sizes, the Sunscope has no moving parts and is fully maintenance-free. The system was designed for use in commercial and residential applications. 7 figs.

  18. Mid infrared upconversion spectroscopy using diffuse reflectance

    DEFF Research Database (Denmark)

    Sanders, Nicolai Højer; Kehlet, Louis M.; Dam, Jeppe Seidelin

    2014-01-01

    specifically that upconversion methods can be deployed using a diffuse reflectance setup where the test sample is irradiated by a thermal light source, i.e. a globar. The diffuse reflectance geometry is particularly well suited when a transmission setup cannot be used. This situation may happen for highly...

  19. Noninvasive assessment of articular cartilage surface damage using reflected polarized light microscopy

    Science.gov (United States)

    Huynh, Ruby N.; Nehmetallah, George; Raub, Christopher B.

    2017-06-01

    Articular surface damage occurs to cartilage during normal aging, osteoarthritis, and in trauma. A noninvasive assessment of cartilage microstructural alterations is useful for studies involving cartilage explants. This study evaluates polarized reflectance microscopy as a tool to assess surface damage to cartilage explants caused by mechanical scraping and enzymatic degradation. Adult bovine articular cartilage explants were scraped, incubated in collagenase, or underwent scrape and collagenase treatments. In an additional experiment, cartilage explants were subject to scrapes at graduated levels of severity. Polarized reflectance parameters were compared with India ink surface staining, features of histological sections, changes in explant wet weight and thickness, and chondrocyte viability. The polarized reflectance signal was sensitive to surface scrape damage and revealed individual scrape features consistent with India ink marks. Following surface treatments, the reflectance contrast parameter was elevated and correlated with image area fraction of India ink. After extensive scraping, polarized reflectance contrast and chondrocyte viability were lower than that from untreated explants. As part of this work, a mathematical model was developed and confirmed the trend in the reflectance signal due to changes in surface scattering and subsurface birefringence. These results demonstrate the effectiveness of polarized reflectance microscopy to sensitively assess surface microstructural alterations in articular cartilage explants.

  20. Nordic Lighting?

    DEFF Research Database (Denmark)

    Munch, Anders V.

    2018-01-01

    The Danish designer Poul Henningsen wrote very elaborated theories of interior lighting from the mid-1920s on. He fought against the cold and reduced light quality of electric bulbs and tried to tame and cultivate this technology by design. He wanted a more rich light for domestic purpose...... worthwhile discussing than other design categories to interpret, whether experience of nature and climatic conditions play a role in Scandinavian Design, as repeatedly stated. This discussion contributes both to understanding of interior lighting and the historiographical critique of Scandinavian Design...... and shaped it through lamp design, colour reflections and differentiated use of several lamps in the room to make a more dim lighting, but with greater variation and softer contrasts. It was a ‘culture’ of lighting, he promoted, but he didn’t saw it as linked to the Nordic countries. His sensibility...

  1. Total-reflection X-ray fluorescence: An alternative tool for the analysis of magnetic ferrofluids

    Energy Technology Data Exchange (ETDEWEB)

    Fernandez-Ruiz, R. [Servicio Interdepartamental de Investigacion (SIdI), Facultad de Ciencias, Universidad Autonoma de Madrid, Cantoblanco, E-28049, Madrid (Spain)], E-mail: ramon.fernandez@uam.es; Costo, R.; Morales, M.P.; Bomati-Miguel, O.; Veintemillas-Verdaguer, S. [Instituto de Ciencia de Materiales de Madrid, CSIC, Cantoblanco, E-28049, Madrid (Spain)

    2008-12-15

    This work presents the first application of the total-reflection X-ray fluorescence (TXRF) to the compositional study of magnetic ferrofluids. With the aims of validating the best analytical conditions and also, limitations of the TXRF in the compositional study of these materials, an alternative empirical method, based in the use of angle-dependence TXRF (AD-TXRF) measurements, is proposed. Three kinds of ferromagnetic nanoparticles, with different morphologies, have been studied. The techniques of inductively coupled plasma mass spectrometry (ICP-MS) and inductively coupled plasma optical emission spectroscopy (ICP-OES) have been used to validate the TXRF results. In contrast with the plasma techniques, the developed TXRF procedure need not of previous chemical acid digestion. Additionally, two procedures of magnetic nanoparticles synthesis, co-precipitation and laser-pyrolysis, have been checked for the contaminants trace metals Zn, Mn and Cr. It has been found that the method of laser-pyrolysis produces nanoparticles of higher purity.

  2. Comparison of ultraviolet Bi-directional Reflectance Distribution Function (BRDF) measurements of diffusers used in the calibration of the Total Ozone Mapping Spectrometer (TOMS)

    NARCIS (Netherlands)

    Butler, J.J.; Park, H.; Barnes, P.Y.; Early, E.A.; Eijk-Olij, C. van; Zoutman, A.E.; Buller-Leeuwen, S. van; Groote Schaarsberg, J.

    2002-01-01

    The measurement and long-term monitoring of global total ozone by ultraviolet albedo measuring satellite instruments require accurate and precise determination of the Bi-directional Reflectance Distribution Function (BRDF) of laboratory-based diffusers used in the pre-launch calibration of those

  3. Hygrothermal degradation of (3-glycidoxypropyl)trimethoxysilane films studied by neutron and X-ray reflectivity and attenuated total reflection infrared spectroscopy

    International Nuclear Information System (INIS)

    Tallant, David Robert; Garcia, Manuel Joseph; Majewski, Jaroslaw; Kent, Michael Stuart; Yim, Hyun

    2005-01-01

    Thin films of organosilanes have great technological importance in the areas of adhesion promotion, durability, and corrosion resistance. However, it is well-known that water can degrade organosilane films, particularly at elevated temperatures. In this work, X-ray and neutron reflectivity (XR and NR) were combined with attenuated total reflection infrared (ATR-IR) spectroscopy to study the chemical and structural changes within thin films of (3-glycidoxypropyl)trimethoxysilane (GPS) after exposure for various periods of time to air saturated with either D 2 O or H 2 O at 80 C. For NR and XR, ultrathin (∼100 (angstrom)) films were prepared by spin-coating. Both D 2 O and H 2 O provide neutron scattering contrast with GPS. Variations in the neutron scattering length density (SLD) profiles (a function of mass density and atomic composition) with conditioning time were measured after drying the samples out and also swelled with H 2 O or D 2 O vapor at room temperature. For samples that were dried out prior to measurement, little or no change was observed for H 2 O conditioning up to 3.5 days, but large changes were observed after 30 days of conditioning. The range of conditioning time for this structural change was narrowed to between 4 and 10 days with XR. The SLD profiles indicated that the top portion of the GPS film was transformed into a thick low-density layer after conditioning, but the bottom portion showed little structural change. A previous NR study of as-prepared GPS films involving swelling with deuterated nitrobenzene showed that the central portion of the film has much lower cross-link density than the region nearest the substrate. The present data show that the central portion also swells to a much greater extent with water and hydrolyzes more rapidly. The chemical degradation mechanism was identified by IR as hydrolysis of siloxane bonds. For ATR-IR, GPS films were prepared by dip-coating, which resulted in a greater and more variable thickness than

  4. Trace elemental analysis of leaching solutions of hijiki seaweeds by a portable total reflection X-ray fluorescence spectrometer

    International Nuclear Information System (INIS)

    Liu, Ying; Imashuku, Susumu; Kawai, Jun

    2014-01-01

    A portable total reflection X-ray fluorescence spectrometer (TXRF) was used to analyze leaching solutions of hijiki seaweeds. S, Cl, K, Ca, Ti, Fe, Ni, As and Br were detected in the solutions. Arsenic quantification results were compared to those from ICP-AES. The TXRF quantification results of arsenic were not significantly different from those of ICP-AES, as two-way analysis of variance (ANOVA) method was applied to the significance test. This kind of small and high sensitive TXRF spectrometer can be used in food quality and environmental pollution investigation. (author)

  5. Photoperiod and temperature constraints on the relationship between the photochemical reflectance index and the light use efficiency of photosynthesis in Pinus strobus

    OpenAIRE

    Fr?chette, Emmanuelle; Chang, Christine Yao-Yun; Ensminger, Ingo

    2016-01-01

    The photochemical reflectance index (PRI) is a proxy for the activity of the photoprotective xanthophyll cycle and photosynthetic light use efficiency (LUE) in plants. Evergreen conifers downregulate photosynthesis in autumn in response to low temperature and shorter photoperiod, and the dynamic xanthophyll cycle-mediated non-photochemical quenching (NPQ) is replaced by sustained NPQ. We hypothesized that this shift in xanthophyll cycle-dependent energy partitioning during the autumn is the c...

  6. Robust sensor for turbidity measurement from light scattering and absorbing liquids.

    Science.gov (United States)

    Kontturi, Ville; Turunen, Petri; Uozumi, Jun; Peiponen, Kai-Erik

    2009-12-01

    Internationally standardized turbidity measurements for probing solid particles in liquid are problematic in the case of simultaneous light scattering and absorption. A method and a sensor to determine the turbidity in the presence of light absorption are presented. The developed sensor makes use of the total internal reflection of a laser beam at the liquid-prism interface, and the turbidity is assessed using the concept of laser speckle pattern. Using average filtering in speckle data analyzing the observed dynamic speckle pattern, which is due to light scattering from particles and the static speckle due to stray light of the sensor, can be separated from each other. Good correlation between the standard deviation of dynamic speckle and turbidity value for nonabsorbing and for absorbing liquids was observed. The sensor is suggested, for instance, for the measurement of ill-behaved as well as small-volume turbid liquids in both medicine and process industry.

  7. Gold nanoparticle-polydimethylsiloxane films reflect light internally by optical diffraction and Mie scattering

    International Nuclear Information System (INIS)

    Dunklin, Jeremy R; Keith Roper, D; Forcherio, Gregory T

    2015-01-01

    Optical properties of polymer films embedded with plasmonic nanoparticles (NPs) are important in many implementations. In this work, optical extinction by polydimethylsiloxane (PDMS) films containing gold (Au) NPs was enhanced at resonance compared to AuNPs in suspensions, Beer–Lambert law, or Mie theory by internal reflection due to optical diffraction in 16 nm AuNP–PDMS films and Mie scattering in 76 nm AuNP–PDMS films. Resonant extinction per AuNP for 16 nm AuNPs with negligible resonant Mie scattering was enhanced up to 1.5-fold at interparticle separation (i.e., Wigner–Seitz radii) comparable to incident wavelength. It was attributable to diffraction through apertures formed by overlapping electric fields of adjacent, resonantly excited AuNPs at Wigner–Seitz radii equal to or less than incident wavelengths. Resonant extinction per AuNP for strongly Mie scattering 76 nm AuNPs was enhanced up to 1.3-fold at Wigner–Seitz radii four or more times greater than incident wavelength. Enhanced light trapping from diffraction and/or scattering is relevant to optoelectronic, biomedical, and catalytic activity of substrates embedded with NPs. (paper)

  8. Measuring thin films using quantitative frustrated total internal reflection (FTIR)

    NARCIS (Netherlands)

    Shirota, Minori; van Limbeek, Michiel A.J.; Lohse, Detlef; Sun, Chao

    2017-01-01

    Abstract.: In the study of interactions between liquids and solids, an accurate measurement of the film thickness between the two media is essential to study the dynamics. As interferometry is restricted by the wavelength of the light source used, recent studies of thinner films have prompted the

  9. Light-material interactions in laser material processing

    International Nuclear Information System (INIS)

    Chiang, S.; Albright, C.E.

    1989-01-01

    The authors discusses how light interactions with materials in laser material processing operations occur by a variety of mechanisms depending on the material being processed, the wavelength of the laser light, the gaseous environment, and the physical state of the material surface. The high reflectivity of metals limits the fraction of the beam power absorbed by the solid metal surface. For metals in the solid state, reflectivity increases as the wavelength of the laser light and the electrical conductivity of the metal increase. The reflectivity of metals is reduced upon heating to the melting point, and further reduced upon melting. At high power densities the liquid metal surface is heated so quickly that very rapid vaporization occurs. The recoil force produced by the evaporation causes a depression in the liquid/vapor interface. The keyhole resulting from this depression allows for multiple reflections and thus increases beam absorption in the liquid

  10. Measurement of reflectance of coal macerals: its automation and significance

    Energy Technology Data Exchange (ETDEWEB)

    Davis, A.

    1978-06-01

    A prime objective of the Pennsylvania State University's DOE program is the characterization of 1,300 samples of U.S. coals. Reflectance determination plays a major role in meeting this objective, because it is used as an accurate rank index both to select coals for testing and to investigate property-behavior interrelationships using the Penn State/DOE Coal Data Base. Reflectances of coal macerals are related to their refractive and absorptive indices by the Beer equation; the refractive index of the medium and the wavelength of light need to be specified. Determinations usually are made in immersion oil at 546 nm. Properties of vitrinite make it the most suitable maceral for these measurements, but the variety of vitrinite selected may depend upon the intended application. Vitrinite reflectance is considered to be dependent upon the degree of aromatization of its structural units. Although some of the earlier investigators believed that the reflectance of coals increased in a discontinuous, stepped manner as their rank increased, the bulk of assembled data suggests that the change is continuous. Some recent results indicate that there may be more than one coalification track for coals with different geological histories, resulting in displacement from the general trend. Several techniques have been employed to determine the optical properties of coal constituents. Usual comparative method involves the use of a microscope photometer to compare the intensity of light reflected by particles within a polished pellet of coal to that of a glass or synthetic mineral standard. Because coal is anisotropic it is common to measure either maximum reflectance in polarized light or random reflectance in non-polarized light. Various eqipment modifications and accessories have been used to improve the ease of measuring maximum reflectance.

  11. Nanoimprint lithography of light trapping patterns in sol-gel coatings for thin film silicon solar cells

    Energy Technology Data Exchange (ETDEWEB)

    Heijna, M.; Loffler, J.; Van Aken, B.B.; Soppe, W.J. [ECN Solar Energy, Petten (Netherlands); Borg, H.; Peeters, P. [OM and T, Eindhoven (Netherlands)

    2008-04-15

    For thin-film silicon solar cells, light trapping schemes are of uppermost importance to harvest all available sunlight. Typically, randomly textured TCO front layers are used to scatter the light diffusively in p-i-n cells on glass. Here, we investigate methods to texture the back contact with both random and periodic textures, for use in n-i-p cells on opaque foil. We applied an electrically insulating SiOx-polymer coating on a stainless steel substrate, and textured this barrier layer by nanoimprint. On this barrier layer the back contact is deposited for further use in the solar cell stack. Replication of masters with various random and periodic patterns was tested, and, using scanning electron microscopy, replicas were found to compare well with the originals. Masters with U-grooves of various sub micrometer widths have been used to investigate the optimal dimensions of regular patterns for light trapping in the silicon layers. Angular reflection distributions were measured to evaluate the light scattering properties of both periodic and random patterns. Diffraction gratings show promising results in scattering the light to specific angles, enhancing the total internal reflection in the solar cell.

  12. Light Sources and Lighting Circuits

    Science.gov (United States)

    Honda, Hisashi; Suwa, Takumi; Yasuda, Takeo; Ohtani, Yoshihiko; Maehara, Akiyoshi; Okada, Atsunori; Komatsu, Naoki; Mannami, Tomoaki

    According to the Machinery Statistics of the Ministry of Economy, Trade and Industry, the production of incandescent lamps in Japan in 2007 was 990 million units (90.0% of the previous year's total), in which the production of incandescent lamps for general lighting was 110 million units (90.0% of the previous year's total) and of tungsten-halogen lamps was 44 million units (96.6% of the previous year's total). The production of fluorescent lamps was 927 million units (93.9% of the previous year's total), in which general fluorescent lamps, excluding those for LCD back lighting, was 320 million units (87.2% of the previous year's total). Also, the production of HID lamps was 10 million units (101.5% of the previous year's total). On the other hand, when the numbers of sales are compared with the sales of the previous year, incandescent lamps for general use was 99.8%, tungsten-halogen lamps was 96.9%, fluorescent lamps was 95.9%, and HID lamps was 98.9%. Self-ballasted fluorescent lamps alone showed an increase in sales as strong as 29 million units, or 121.7% of the previous year's sales. It is considered that the switchover of incandescent lamps to HID lamps was promoted for energy conservation and carbon dioxide reduction with the problem of global warming in the background. In regard to exhibitions, Lighting Fair 2007 was held in Tokyo in March, and LIGHTFAIR INTERNATIONAL 2007 was held in New York in May. Regarding academic conferences, LS:11 (the 11th International Symposium on the Science & Technology of Light Sources) was held in Shanghai in May, and the First International Conference on White LEDs and Solid State Lighting was held in Tokyo in November. Both conferences suggested that there are strong needs and concerns now about energy conservation, saving natural resources, and restrictions of hazardous materials. In regard to incandescent lamps, the development of products aiming at higher efficacy, electric power savings, and longer life was advanced by

  13. Hydrogels for efficient light delivery in optogenetic applications

    Science.gov (United States)

    Johannsmeier, S.; Torres, M. L.; Ripken, T.; Heinemann, D.; Heisterkamp, A.

    2018-02-01

    Light-based therapies have been established for various indications, such as skin conditions, cancer or neonatal jaundice. Advances in the field of optogenetics open up new horizons for light-tissue interactions with an organism-wide impact. Excitable tissues, such as nerve and muscle tissues, can be controlled by light after the introduction of light-sensitive ion channels. Since these organs are generally not easily accessible to illumination in vivo, there is an increasing need for effective biocompatible waveguides for light delivery. These devices not only have to guide and distribute the light as desired with minimal losses, they should also mimic the mechanical properties of the surrounding tissue to ensure compatibility. In this project, we are tuning the properties of hydrogels from poly(ethylene glycol) derivatives to achieve compatibility with muscle tissue as well as optimal light guiding and distribution for optogenetic applications at the heart. The excitation light is coupled into the hydrogel with a biocompatible fiber. Properties of the hydrogel are mainly tuned by monomer length and concentration. Total reflection can be achieved by embedding a fiber-like hydrogel with a high refractive index into a second, low refractive index gel. Different geometries and scattering microparticles are used for light distribution in a flat gel patch. Targeted cell attachment can be achieved by introducing a protein layer to the otherwise bioinert gel. After optimization, the hydrogel may be used to deliver light for the excitation of genetically altered cardiomyocytes for controlled contraction.

  14. Lifelog-based lighting design for biofied building

    Science.gov (United States)

    Kake, Fumika; Mita, Akira

    2016-04-01

    A design tool is proposed for lighting control system that reflects histories of residents' past life using a genetic mechanism. There are many previous researches which show the preference of lighting design differs depending on people and their behaviors. And recently, due to the appearance of LED which can change light color easily, the number of lighting scenes have drastically increased. It is difficult for residents to grasp all patterns of lighting and understand what pattern of lighting design fits for their behaviors. So if we can extract lighting preferences and demands of each resident from histories of past life and reflect these information in next lighting control, it's possible to make living space more comfortable. An evolutionally adaptation mechanism learnt from living organisms is proposed in this research to extract the information from lifelog, especially focusing on methylation and mutation. Methylation is one of the epigenetic algorithms making a difference in phenotype without changing DNA sequence. Mutation is one of the genetic algorithms making a difference in phenotype by changing DNA sequence. Those two mechanisms are applied in the system. First, the lifelog of residents and using hysteresis of lighting equipment are collected. Then the lifelog is converted into the genetic information and stored. When the lifelog is stored enough, the superior genes will be picked up from the stored genetic information to be reflected in lighting control in next generation. Simulations to verify the versatility of the system were conducted.

  15. High-accuracy self-mixing interferometer based on multiple reflections using a simple external reflecting mirror

    Science.gov (United States)

    Wang, Xiu-lin; Wei, Zheng; Wang, Rui; Huang, Wen-cai

    2018-05-01

    A self-mixing interferometer (SMI) with resolution twenty times higher than that of a conventional interferometer is developed by multiple reflections. Only by employing a simple external reflecting mirror, the multiple-pass optical configuration can be constructed. The advantage of the configuration is simple and easy to make the light re-injected back into the laser cavity. Theoretical analysis shows that the resolution of measurement is scalable by adjusting the number of reflections. The experiment shows that the proposed method has the optical resolution of approximate λ/40. The influence of displacement sensitivity gain ( G) is further analyzed and discussed in practical experiments.

  16. Estimation of light source colours for light pollution assessment.

    Science.gov (United States)

    Ziou, D; Kerouh, F

    2018-05-01

    The concept of the smart city raised several technological and scientific issues including light pollution. There are various negative impacts of light pollution on economy, ecology, and heath. This paper deals with the census of the colour of light emitted by lamps used in a city environment. To this end, we derive a light bulb colour estimator based on Bayesian reasoning, directional data, and image formation model in which the usual concept of reflectance is not used. All choices we made are devoted to designing an algorithm which can be run almost in real-time. Experimental results show the effectiveness of the proposed approach. Copyright © 2018 Elsevier Ltd. All rights reserved.

  17. Controllable transmission and total reflection through an impedance-matched acoustic metasurface

    KAUST Repository

    Mei, Jun; Wu, Ying

    2014-01-01

    supplies the functionalities of reflection-type acoustic metasurfaces, but also exhibits unprecedented flexibility and efficiency in various domains of wave manipulation for possible applications in fields like refracting, collimating, focusing or absorbing

  18. Office lighting systems: Optimization

    Energy Technology Data Exchange (ETDEWEB)

    Dagnino, U. (ENEL, Milan (Italy))

    1990-09-01

    Relative to office lighting systems, in particular, those making use of tubular fluorescent lamps, currently available on the international market, this paper tries to develop lighting system, design optimization criteria. The comparative assessment of the various design possibilities considers operating cost, energy consumption, and occupational comfort/safety aspects such as lighting level uniformity and equilibrium, reduction of glare and reflection, natural/artificial lighting balance, programmed switching, computerized control systems for multi-use requirements in large areas, programmed maintenance for greater efficiency and reliability.

  19. Simulation of attenuated total reflection infrared absorbance spectra: applications to automotive clear coat forensic analysis.

    Science.gov (United States)

    Lavine, Barry K; Fasasi, Ayuba; Mirjankar, Nikhil; Nishikida, Koichi; Campbell, Jay

    2014-01-01

    Attenuated total reflection (ATR) is a widely used sampling technique in infrared (IR) spectroscopy because minimal sample preparation is required. Since the penetration depth of the ATR analysis beam is quite shallow, the outer layers of a laminate or multilayered paint sample can be preferentially analyzed with the entire sample intact. For this reason, forensic laboratories are taking advantage of ATR to collect IR spectra of automotive paint systems that may consist of three or more layers. However, the IR spectrum of a paint sample obtained by ATR will exhibit distortions, e.g., band broadening and lower relative intensities at higher wavenumbers, compared with its transmission counterpart. This hinders library searching because most library spectra are measured in transmission mode. Furthermore, the angle of incidence for the internal reflection element, the refractive index of the clear coat, and surface contamination due to inorganic contaminants can profoundly influence the quality of the ATR spectrum obtained for automotive paints. A correction algorithm to allow ATR spectra to be searched using IR transmission spectra of the paint data query (PDQ) automotive database is presented. The proposed correction algorithm to convert transmission spectra from the PDQ library to ATR spectra is able to address distortion issues such as the relative intensities and broadening of the bands, and the introduction of wavelength shifts at lower frequencies, which prevent library searching of ATR spectra using archived IR transmission data.

  20. Novel Fiber Optic Sensor Probe with a Pair of Highly Reflected Connectors and a Vessel of Water Absorption Material for Water Leak Detection

    Directory of Open Access Journals (Sweden)

    Tae-Sik Cho

    2012-08-01

    Full Text Available The use of a fiber optic quasi-distributed sensing technique for detecting the location and severity of water leakage is suggested. A novel fiber optic sensor probe is devised with a vessel of water absorption material called as water combination soil (WCS located between two highly reflected connectors: one is a reference connector and the other is a sensing connector. In this study, the sensing output is calculated from the reflected light signals of the two connectors. The first reflected light signal is a reference and the second is a sensing signal which is attenuated by the optical fiber bending loss due to the WCS expansion absorbing water. Also, the bending loss of each sensor probe is determined by referring to the total number of sensor probes and the total power budget of an entire system. We have investigated several probe characteristics to show the design feasibility of the novel fiber sensor probe. The effects of vessel sizes of the probes on the water detection sensitivity are studied. The largest vessel probe provides the highest sensitivity of 0.267 dB/mL, while the smallest shows relatively low sensitivity of 0.067 dB/mL, and unstable response. The sensor probe with a high output value provides a high sensitivity with various detection levels while the number of total installable sensor probes decreases.

  1. Novel fiber optic sensor probe with a pair of highly reflected connectors and a vessel of water absorption material for water leak detection.

    Science.gov (United States)

    Cho, Tae-Sik; Choi, Ki-Sun; Seo, Dae-Cheol; Kwon, Il-Bum; Lee, Jung-Ryul

    2012-01-01

    The use of a fiber optic quasi-distributed sensing technique for detecting the location and severity of water leakage is suggested. A novel fiber optic sensor probe is devised with a vessel of water absorption material called as water combination soil (WCS) located between two highly reflected connectors: one is a reference connector and the other is a sensing connector. In this study, the sensing output is calculated from the reflected light signals of the two connectors. The first reflected light signal is a reference and the second is a sensing signal which is attenuated by the optical fiber bending loss due to the WCS expansion absorbing water. Also, the bending loss of each sensor probe is determined by referring to the total number of sensor probes and the total power budget of an entire system. We have investigated several probe characteristics to show the design feasibility of the novel fiber sensor probe. The effects of vessel sizes of the probes on the water detection sensitivity are studied. The largest vessel probe provides the highest sensitivity of 0.267 dB/mL, while the smallest shows relatively low sensitivity of 0.067 dB/mL, and unstable response. The sensor probe with a high output value provides a high sensitivity with various detection levels while the number of total installable sensor probes decreases.

  2. The nonlinear light output of NaI(Tl) detectors in the Modular Total Absorption Spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Rasco, B.C., E-mail: crasco@lsu.edu [Department of Physics and Astronomy, Louisiana State University, Baton Rouge, LA 70803 (United States); Fijałkowska, A.; Karny, M. [Faculty of Physics, University of Warsaw, Pasteura 5, PL-02093 Warszawa (Poland); Rykaczewski, K.P. [Physics Division, Oak Ridge National Laboratory, Oak Ridge, TN 37831 (United States); Wolińska-Cichocka, M. [Physics Division, Oak Ridge National Laboratory, Oak Ridge, TN 37831 (United States); Oak Ridge Associated Universities, Oak Ridge, TN 37831 (United States); Heavy Ion Laboratory, University of Warsaw, Warsaw PL-02-093 (Poland); Grzywacz, R.; Goetz, K.C. [Department of Physics and Astronomy, University of Tennessee, Knoxville, TN 37966 (United States)

    2015-07-11

    A new detector array, the Modular Total Absorption Spectrometer (MTAS), was commissioned at the Holifield Radioactive Ion Beam Facility (HRIBF) at Oak Ridge National Lab (ORNL). Total absorption gamma spectra measured with MTAS are expected to improve beta-feeding patterns and beta strength functions in fission products. MTAS is constructed out of hexagonal NaI(Tl) detectors with a unique central module surrounded by 18 identical crystals assembled in three rings. The total NaI(Tl) mass of MTAS is over 1000 kg. The response of the central and other 18 MTAS modules to γ-radiation was simulated using the GEANT4 toolkit modified to analyze the nonlinear light output of NaI(Tl). A detailed description of the GEANT4 modifications made is discussed. Simulated energy resolution of MTAS modules is found to agree well with the measurements for single γ transitions of 662 keV ({sup 137}Cs) with 8.2% full width half maximum (FWHM), 835 keV ({sup 54}Mn) with FWHM of 7.5% FWHM, and 1115 keV ({sup 65}Zn) with FWHM of 6.5%. Simulations of single and multiple γ-rays from {sup 60}Co are also discussed.

  3. THE VARIABLE REFLECTION NEBULA CEPHEUS A EAST

    International Nuclear Information System (INIS)

    Hodapp, Klaus W.; Bressert, Eli

    2009-01-01

    We report K'-band imaging observations of the reflection nebula associated with Cepheus A East covering the time interval from 1990 to 2004. Over this time the reflection nebula shows variations of flux distribution, which we interpret as the effect of inhomogeneous and varying extinction in the light path from the illuminating source HW2 to the reflection nebula. The obscuring material is located within typical distances of ∼ 10 AU from the illuminating source.

  4. STUDY OF INK LAYER BY METHOD OF ATTENUATED TOTAL REFLECTANCE SPECTROSCOPY

    Directory of Open Access Journals (Sweden)

    D. G. Fatkhullina

    2016-05-01

    Full Text Available Subject of Research. Researchresults of thickness distribution of an ink layer smearedon a glass surface are presented. The orange ink which is used as a coloring pigment in writing instrument (highlighter is selectedasan object of study. Method. Researches were carried out by the method of attenuated total reflectance(ATR spectroscopy. The spectral setup fitted up on the basis of monochromator MDR-204 was usedin the experiment. The peculiarity of the measurement scheme is the applicationofhigh-resolution camera as a radiation detector and information storage as an images package. Researches allowed receivingexperimental data in the form of ink ATR spectra arrayfor studied areas of layer surface in a given spectral range. Main Results. The estimation of ink layer thickness was done, that gives the possibilityto visualize its distribution over the surface using three-dimensional modeling capabilities. The thickness of the ink layer is not more than 0.12 microns and arithmetic mean of the thickness is0.06 microns. The local areas are observed in an ink distribution, they have a maximum layer thickness (0.07-0.12 microns or areas with the ink thickness less then 0.03 microns. Variation of the ink layer thicknessbetween the local areas is smooth. Practical Relevance. The proposed measuring scheme, the sequence of registration and processing of experimental data can be used to studyink distribution within the thickness of a surface layer of other materials,for example, in analysis of signs performed by an ink on paper medium in order to identify them in such areas of science as forensic science andstudy of art.

  5. Change in spatial coherence of light on refraction and on reflection.

    Science.gov (United States)

    Lahiri, Mayukh; Wolf, Emil

    2013-06-01

    A theory of refraction and reflection of partially coherent electromagnetic beams has been recently developed. In this paper, we apply it to study the change in spatial coherence caused by refraction and by reflection more fully. By considering a Gaussian Schell-model beam, we show that the change is, in general, dependent on the angle of incidence.

  6. Application of linear discriminant analysis and Attenuated Total Reflectance Fourier Transform Infrared microspectroscopy for diagnosis of colon cancer.

    Science.gov (United States)

    Khanmohammadi, Mohammadreza; Bagheri Garmarudi, Amir; Samani, Simin; Ghasemi, Keyvan; Ashuri, Ahmad

    2011-06-01

    Attenuated Total Reflectance Fourier Transform Infrared (ATR-FTIR) microspectroscopy was applied for detection of colon cancer according to the spectral features of colon tissues. Supervised classification models can be trained to identify the tissue type based on the spectroscopic fingerprint. A total of 78 colon tissues were used in spectroscopy studies. Major spectral differences were observed in 1,740-900 cm(-1) spectral region. Several chemometric methods such as analysis of variance (ANOVA), cluster analysis (CA) and linear discriminate analysis (LDA) were applied for classification of IR spectra. Utilizing the chemometric techniques, clear and reproducible differences were observed between the spectra of normal and cancer cases, suggesting that infrared microspectroscopy in conjunction with spectral data processing would be useful for diagnostic classification. Using LDA technique, the spectra were classified into cancer and normal tissue classes with an accuracy of 95.8%. The sensitivity and specificity was 100 and 93.1%, respectively.

  7. Determination of the optical constants of polymer light-emitting diode films from single reflection measurements

    International Nuclear Information System (INIS)

    Zhu Dexi; Shen Weidong; Ye Hui; Liu Xu; Zhen Hongyu

    2008-01-01

    We present a simple and fast method to determine the optical constant and physical thickness of polymer films from a single reflectivity measurement. A self-consistent dispersion formula of the Forouhi-Bloomer model was introduced to fit the measured spectral curves by a modified 'Downhill' simplex algorithm. Four widely used polymer light-emitting diodes materials: poly[2-methoxy-5-(2'-ethyl-hexyloxy)-1,4-phenylenevinylene], poly(9,9-dioctylfluoreny-2,7-diyl) (PFO), poly(N-vinyl carbazole) and poly(3,4-ethylene dioxythiophene) : poly(styrenesulfonate) were investigated by this technique. The refractive indices over the whole visible region as well as the optical band gap extracted by this method agree well with those reported in the literature. The determined physical thicknesses present a deviation less than 4% compared with the experimental values measured by the stylus profiler. The influence of scattering loss on the fitted results is discussed to demonstrate the applicability of this technology for polymer films.

  8. An Optical Fiber Read Out Method for a Reflective Microcantilever Biosensor

    Directory of Open Access Journals (Sweden)

    Feng Wen

    2013-03-01

    Full Text Available An effective optical read out approach based on fiber reflective is presented to detect bends of a biomaterial microcantilever. The microcantilever was fabricated on single crystalline SOI wafer using a series of side definitions and backside wet/dry etchings. A Cr/Au layer with 30 nm Cr and 50 nm Au layer was deposited for the immobilized of bimolecular on the cantilever surface and for reflecting the light back into the fiber, the different light intensities means different bimolecular concentrations. The noncoherent light source is a super luminescent LED. Gradient index lens as a collimator and 50:50 optical coupler and signal modefiber was used to transmit light. Two PINFETs were used to convert the reflecting the light intensities and the light sources into electronic signals, two ADCs convert the signal into digital signals, a MPU was used to eliminate the fluctuation of the light source error. The method can has got high sensitivity is 6507.59 mV/um. Though the experiment, the cantilever biosensor can detect glucose, measurement results clearly demonstrate that the output voltage induced by the microcantilevers bending is proportional to the glucose concentrations and the sensitivity is up to 0.1V/mM, which is enough for glucose real-time trace detection.

  9. Reflection and extinction of light by self-assembled monolayers of a quinque-thiophene derivative: A coherent scattering approach

    Energy Technology Data Exchange (ETDEWEB)

    Gholamrezaie, Fatemeh; Meskers, Stefan C. J., E-mail: s.c.j.meskers@tue.nl [Molecular Materials and Nanosystems and Institute of Complex Molecular Systems, Eindhoven University of Technology, P.O. Box 513, 5600 MB Eindhoven (Netherlands); Leeuw, Dago M. de [Max Planck Institute for Polymer Research, Ackermannweg 10, 55128 Mainz (Germany)

    2016-06-07

    Scattering matrix theory is used to describe resonant optical properties of molecular monolayers. Three types of coupling are included: exciton-exciton, exciton-photon, and exciton-phonon coupling. We use the K-matrix formalism, developed originally to describe neutron scattering spectra in nuclear physics to compute the scattering of polaritons by phonons. This perturbation approach takes into account the three couplings and allows one to go beyond molecular exciton theory without the need of introducing additional boundary conditions for the polariton. We demonstrate that reflection, absorption, and extinction of light by 2D self-assembled monolayers of molecules containing quinque-thiophene chromophoric groups can be calculated. The extracted coherence length of the Frenkel exciton is discussed.

  10. Quantitative Analysis of Total Petroleum Hydrocarbons in Soils: Comparison between Reflectance Spectroscopy and Solvent Extraction by 3 Certified Laboratories

    Directory of Open Access Journals (Sweden)

    Guy Schwartz

    2012-01-01

    Full Text Available The commonly used analytic method for assessing total petroleum hydrocarbons (TPH in soil, EPA method 418.1, is usually based on extraction with 1,1,2-trichlorotrifluoroethane (Freon 113 and FTIR spectroscopy of the extracted solvent. This method is widely used for initial site investigation, due to the relative low price per sample. It is known that the extraction efficiency varies depending on the extracting solvent and other sample properties. This study’s main goal was to evaluate reflectance spectroscopy as a tool for TPH assessment, as compared with three commercial certified laboratories using traditional methods. Large variations were found between the results of the three commercial laboratories, both internally (average deviation up to 20%, and between laboratories (average deviation up to 103%. Reflectance spectroscopy method was found be as good as the commercial laboratories in terms of accuracy and could be a viable field-screening tool that is rapid, environmental friendly, and cost effective.

  11. Numerical and experimental investigation of GaN-based flip-chip light-emitting diodes with highly reflective Ag/TiW and ITO/DBR Ohmic contacts.

    Science.gov (United States)

    Zhou, Shengjun; Liu, Xingtong; Gao, Yilin; Liu, Yingce; Liu, Mengling; Liu, Zongyuan; Gui, Chengqun; Liu, Sheng

    2017-10-30

    We demonstrate two types of GaN-based flip-chip light-emitting diodes (FCLEDs) with highly reflective Ag/TiW and indium-tin oxide (ITO)/distributed Bragg reflector (DBR) p-type Ohmic contacts. We show that a direct Ohmic contact to p-GaN layer using pure Ag is obtained when annealed at 600°C in N 2 ambient. A TiW diffusion barrier layer covered onto Ag is used to suppress the agglomeration of Ag and thus maintain high reflectance of Ag during high temperature annealing process. We develop a strip-shaped SiO 2 current blocking layer beneath the ITO/DBR to alleviate current crowding occurring in FCLED with ITO/DBR. Owing to negligibly small spreading resistance of Ag, however, our combined numerical and experimental results show that the FCLED with Ag/TiW has a more favorable current spreading uniformity in comparison to the FCLED with ITO/DBR. As a result, the light output power of FCLED with Ag/TiW is 7.5% higher than that of FCLED with ITO/DBR at 350 mA. The maximum output power of the FCLED with Ag/TiW obtained at 305.6 A/cm 2 is 29.3% larger than that of the FCLED with ITO/DBR obtained at 278.9 A/cm 2 . The improvement appears to be due to the enhanced current spreading and higher optical reflectance provided by the Ag/TiW.

  12. Effect of nuclear track on reflectivity for insulating material

    International Nuclear Information System (INIS)

    Liu Cunxiong; Ni Bangfa; Tian Weizhi; Hu Lian; Xiao Caijin; Wang Pingsheng; Zhang Guiying; Huang Donghui; Lu Peng; Yang Weitao

    2009-01-01

    Polyester and CR-39 samples were irradiated with sulphur ion from HI-13 tandem accelerator. Ultraviolet light with wavelength 360 nm was used to sensitize the polymer before chemical etching by NaOH solution with different temperatures and time duration. The latent track was then developed into nanometer to micrometer pore with certain depth. Samples were coated with thin layer of silver and magnesium fluoride using the vacuum evaporator. The reflectivity and transmission index were measured for all polymer samples, untreated and treated with above-mentioned procedure, within the wavelength of visible light. Solid state nuclear track and coating can reduce reflectivity of tested polymer materials greatly, and the reflectivity can be 1% or lower. (authors)

  13. Multielement determination in river-water of Sepetiba Bay tributaries (Brazil) by total reflection X-ray fluorescence using synchrotron radiation

    International Nuclear Information System (INIS)

    Costa, A.C.M.; Castro, C.R.F.; Lopes, R.T.; Anjos, M.J.; Rio de Janeiro State Univ.

    2006-01-01

    Trace elements were determined in the surface waters of tributaries of the Sepetiba Bay, Brazil (Piraque, Ita, Sao Francisco, Guarda, Guandu Mirim, Vala do Sangue and Engenho Novo rivers) by total reflection X-ray fluorescence using synchrotron radiation (SRTXRF). Eighteen trace elements could be determined in the dissolved and the suspended particulate phases: Al, Si, P, S, Cl, K, Ca, Ti, Cr, Mn, Fe, Ni, Cu, Zn, Br, Rb, Sr and Pb. The elemental concentration values were compared to the values recommended by the Brazilian legislation. (author)

  14. Optical observations of Magnetosphere-Ionosphere coupling: Inter-hemispheric electron reflections within pulsating aurora

    Science.gov (United States)

    Samara, M.; Michell, R.; Khazanov, G. V.; Grubbs, G. A., II

    2017-12-01

    Magnetosphere-Ionosphere coupling is exhibited in reflected primary and secondary electrons which constitute the second step in the formation of the total precipitating electron distribution. While they have largely been missing from the current theoretical studies of particle precipitation, ground based observations point to the existence of a reflected electron population. We present evidence that pulsating aurora is caused by electrons bouncing back and forth between the two hemispheres. This means that these electrons are responsible for some of the total light in the aurora, a possibility that has largely been ignored in theoretical models. Pulsating auroral events imaged optically at high time resolution present direct observational evidence in agreement with the inter-hemispheric electron bouncing predicted by the SuperThermal Electron Trans-port (STET) model. Immediately following each of the `pulsation-on' times are equally spaced, and subsequently fainter pulsations, which can be explained by the primary precipitating electrons reflecting upwards from the ionosphere, traveling to the opposite hemisphere, and reflecting upwards again. The high time-resolution of these data, combined with the short duration of the `pulsation-on' time ( 1 s) and the relatively long spacing between pulsations ( 6 to 9 s) made it possible to observe the faint optical pulses caused by the reflected electrons coming from the opposite hemisphere. These results are significant and have broad implications because they highlight that the formation of the auroral electron distributions within regions of diffuse and pulsating aurora contain contributions from reflected primary and secondary electrons. These processes can ultimately lead to larger fluxes than expected when considering only the primary injection of magnetospheric electrons.

  15. Determination of protein concentration in raw milk by mid-infrared fourier transform infrared/attenuated total reflectance spectroscopy.

    Science.gov (United States)

    Etzion, Y; Linker, R; Cogan, U; Shmulevich, I

    2004-09-01

    This study investigates the potential use of attenuated total reflectance spectroscopy in the mid-infrared range for determining protein concentration in raw cow milk. The determination of protein concentration is based on the characteristic absorbance of milk proteins, which includes 2 absorbance bands in the 1500 to 1700 cm(-1) range, known as the amide I and amide II bands, and absorbance in the 1060 to 1100 cm(-1) range, which is associated with phosphate groups covalently bound to casein proteins. To minimize the influence of the strong water band (centered around 1640 cm(-1)) that overlaps with the amide I and amide II bands, an optimized automatic procedure for accurate water subtraction was applied. Following water subtraction, the spectra were analyzed by 3 methods, namely simple band integration, partial least squares (PLS) and neural networks. For the neural network models, the spectra were first decomposed by principal component analysis (PCA), and the neural network inputs were the spectra principal components scores. In addition, the concentrations of 2 constituents expected to interact with the protein (i.e., fat and lactose) were also used as inputs. These approaches were tested with 235 spectra of standardized raw milk samples, corresponding to 26 protein concentrations in the 2.47 to 3.90% (weight per volume) range. The simple integration method led to very poor results, whereas PLS resulted in prediction errors of about 0.22% protein. The neural network approach led to prediction errors of 0.20% protein when based on PCA scores only, and 0.08% protein when lactose and fat concentrations were also included in the model. These results indicate the potential usefulness of Fourier transform infrared/attenuated total reflectance spectroscopy for rapid, possibly online, determination of protein concentration in raw milk.

  16. Electro-optic polymeric reflection modulator based on plasmonic metamaterial

    Science.gov (United States)

    Abbas, A.; Swillam, M.

    2018-02-01

    A novel low power design for polymeric Electro-Optic reflection modulator is proposed based on the Extraordinary Reflection of light from multilayer structure consisting of a plasmonic metasurface with a periodic structure of sub wavelength circular apertures in a gold film above a thin layer of EO polymer and above another thin gold layer. The interference of the different reflected beams from different layer construct the modulated beam, The applied input driving voltage change the polymer refractive index which in turn determine whether the interference is constructive or destructive, so both phase and intensity modulation could be achieved. The resonant wavelength is tuned to the standard telecommunication wavelength 1.55μm, at this wavelength the reflection is minimum, while the absorption is maximum due to plasmonic resonance (PR) and the coupling between the incident light and the plasmonic metasurface.

  17. Absence of an increase in the duration of the circadian melatonin secretory episode in totally blind human subjects

    Science.gov (United States)

    Klerman, E. B.; Zeitzer, J. M.; Duffy, J. F.; Khalsa, S. B.; Czeisler, C. A.

    2001-01-01

    The daily rhythm of melatonin influences multiple physiological measures, including sleep tendency, circadian rhythms, and reproductive function in seasonally breeding mammals. The biological signal for photoperiodic changes in seasonally breeding mammals is a change in the duration of melatonin secretion, which in a natural environment reflects the different durations of daylight across the year, with longer nights leading to a longer duration of melatonin secretion. These seasonal changes in the duration of melatonin secretion do not simply reflect the known acute suppression of melatonin secretion by ocular light exposure, but also represent long-term changes in the endogenous nocturnal melatonin episode that persist in constant conditions. As the eyes of totally blind individuals do not transmit ocular light information, we hypothesized that the duration of the melatonin secretory episode in blind subjects would be longer than those in sighted individuals, who are exposed to light for all their waking hours in an urban environment. We assessed the melatonin secretory profile during constant posture, dim light conditions in 17 blind and 157 sighted adults, all of whom were healthy and using no prescription or nonprescription medications. The duration of melatonin secretion was not significantly different between blind and sighted individuals. Healthy blind individuals after years without ocular light exposure do not have a longer duration of melatonin secretion than healthy sighted individuals.

  18. Inverted-conical light guide for crosstalk reduction in tightly-packed scintillator matrix and MAPMT assembly

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Y.-Y., E-mail: gixd@hep1.phys.ntu.edu.tw [Department of Physics, National Taiwan University, 1 Roosevelt Rd., Taipei 10617, Taiwan, ROC (China); Leung Center for Cosmology and Particle Astrophysics, National Taiwan University, 1 Roosevelt Rd., Taipei 10617, Taiwan, ROC (China); Chen, C.R. [National Space Organization (NSPO), 8F., No. 9, Prosperity 1 s Rd., Hsinchu Science Park, Hsinchu 30078, Taiwan, ROC (China); Chen, P.; Huang, J.-J. [Department of Physics, National Taiwan University, 1 Roosevelt Rd., Taipei 10617, Taiwan, ROC (China); Leung Center for Cosmology and Particle Astrophysics, National Taiwan University, 1 Roosevelt Rd., Taipei 10617, Taiwan, ROC (China); Huang, M.A. [Leung Center for Cosmology and Particle Astrophysics, National Taiwan University, 1 Roosevelt Rd., Taipei 10617, Taiwan, ROC (China); Department of Energy Engineering, National United University, 1, Lienda, Miaoli 36003, Taiwan, ROC (China); Liu, T.-C. [Leung Center for Cosmology and Particle Astrophysics, National Taiwan University, 1 Roosevelt Rd., Taipei 10617, Taiwan, ROC (China); Nam, J.W. [Department of Physics, National Taiwan University, 1 Roosevelt Rd., Taipei 10617, Taiwan, ROC (China); Leung Center for Cosmology and Particle Astrophysics, National Taiwan University, 1 Roosevelt Rd., Taipei 10617, Taiwan, ROC (China); Wang, M.-Z., E-mail: mzwang@hep1.phys.ntu.edu.tw [Department of Physics, National Taiwan University, 1 Roosevelt Rd., Taipei 10617, Taiwan, ROC (China); Leung Center for Cosmology and Particle Astrophysics, National Taiwan University, 1 Roosevelt Rd., Taipei 10617, Taiwan, ROC (China); Bogomolov, V. [Skobeltsyn Institute of Nuclear Physics of Lomonosov Moscow State University, Leninskie Gory 119234 (Russian Federation); Physics Department of Lomonosov Moscow State University, Leninskie Gory 119234 (Russian Federation); Brandt, S.; Budtz-Jørgensen, C. [National Space Institute, Astrophysics, Technical University of Denmark, DK-2800 Kongens, Lyngby (Denmark); and others

    2015-01-21

    In this paper we present the Inverted-Conical light guide designed for optical crosstalk reduction in the scintillator-MAPMT assemblies. The research was motivated by the 30% crosstalk observed in UFFO X-ray telescope, UBAT, during the preliminary calibration with MAPMTs of 64 2.88×2.88 mm{sup 2} pixels and identically gridded YSO crystal matrices. We began the study with the energy and crosstalk calibrations of the detector, then we constructed a GEANT4 simulation with the customized metallic film model as the MAPMT photocathode. The simulation reproduced more than 70% of the crosstalk and explained it as a consequence of the total reflection produced by the photocathode. The result indicated that the crosstalk mechanism could be a common case in most of the contact-assembled scintillation detectors. The concept of the Inverted-Conical light guide was to suppress the total reflection by contracting the incident angle of the scintillation. We optimized the design in the simulation and fabricated a test sample. The test sample reduced 52% crosstalk with a loss of 6% signal yield. The idea of the Inverted-Conical light guide can be adapted by scintillation detectors multi-pixel, imaging-purpose scintillation detectors such as the ultra-fast GRB observatory UFFO-UBAT, whose performances are sensitive to responding time, image resolution, and geometrical modifications.

  19. Inverted-conical light guide for crosstalk reduction in tightly-packed scintillator matrix and MAPMT assembly

    International Nuclear Information System (INIS)

    Chang, Y.-Y.; Chen, C.R.; Chen, P.; Huang, J.-J.; Huang, M.A.; Liu, T.-C.; Nam, J.W.; Wang, M.-Z.; Bogomolov, V.; Brandt, S.; Budtz-Jørgensen, C.

    2015-01-01

    In this paper we present the Inverted-Conical light guide designed for optical crosstalk reduction in the scintillator-MAPMT assemblies. The research was motivated by the 30% crosstalk observed in UFFO X-ray telescope, UBAT, during the preliminary calibration with MAPMTs of 64 2.88×2.88 mm 2 pixels and identically gridded YSO crystal matrices. We began the study with the energy and crosstalk calibrations of the detector, then we constructed a GEANT4 simulation with the customized metallic film model as the MAPMT photocathode. The simulation reproduced more than 70% of the crosstalk and explained it as a consequence of the total reflection produced by the photocathode. The result indicated that the crosstalk mechanism could be a common case in most of the contact-assembled scintillation detectors. The concept of the Inverted-Conical light guide was to suppress the total reflection by contracting the incident angle of the scintillation. We optimized the design in the simulation and fabricated a test sample. The test sample reduced 52% crosstalk with a loss of 6% signal yield. The idea of the Inverted-Conical light guide can be adapted by scintillation detectors multi-pixel, imaging-purpose scintillation detectors such as the ultra-fast GRB observatory UFFO-UBAT, whose performances are sensitive to responding time, image resolution, and geometrical modifications

  20. Collection of airborne particulate matter for a subsequent analysis by total reflection X-ray fluorescence

    International Nuclear Information System (INIS)

    Klockenkaemper, R.; Bayer, H.; Bohlen, A. von; Schmeling, M.; Klockow, D.

    1995-01-01

    The collection of airborne particulate matter by filtration and impaction was adapted to total reflection X-ray fluorescence analysis (TXRF). Cellulose nitrate filters were used for collecting in a Berner impactor. Single filter spots were punched out, placed on quartz-glass carriers, dissolved by tetrahydrofuran and re-precipitated prior to element determinations by TXRF. In a Battelle-type impactor, airborne dust was collected on Plexiglass carriers coated with medical Vaseline. The loaded carriers were directly analyzed by TXRF. In both cases, quantification was simply performed by the addition of an internal standard after sampling. Impactors were made of a suitable material in order to investigate high blank values, collection losses and memory effects. It could be shown that stainless steel, even coated with TiN, is less suitable and should be avoided as an impactor material. Although aluminum is partly recommendable, titanium and the polymer Makrolon are quite appropriate. By using an impactor made of these materials, a reliable multielement determination in airborne dust is made possible with low detection limits as low as 1 ng/m 3 and a satisfactory repeatability of a few %. Short sampling times of only 1 h or less can be realized. The total procedure is simple and time-saving, and can be recommended for routine investigations of airborne particulate matter. (author)

  1. Fish samples as bioindicator of environmental quality: synchrotron radiation total reflection X-ray fluorescence analysis (SR-TXRF)

    International Nuclear Information System (INIS)

    Vives, Ana Elisa Sirito de; Moreira, Silvana; Brienza, Sandra Maria Boscolo; Zucchi, Orgheda Luiza Araujo Domingues; Nascimento Filho, Virgilio Franco do Centro de Energia Nuclear na Agricultura , Piracicaba, SP; Brazil)

    2005-01-01

    In this study fish were used as bioindicators of environmental contamination. The species were collected in Piracicaba River, Sao Paulo state, Brazil and the toxic elements concentrations were determined in muscle tissue and viscus (liver, intestine and stomach) by Synchrotron Radiation Total Reflection X-Ray Fluorescence Analysis (SR-TXRF). Were determined the elements Ti, Cr, Mn, Fe, Ni, Cu, Zn and Ba. The results were compared with values established by Brazilian Legislation for general food. The elements concentrations evidenced potential risk to human health and environmental quality alteration of the studied area. The measurements were realized at the 'Laboratorio Nacional de Luz Sincrotron' (LNLS) located in Campinas, Sao Paulo State, Brazil. (author)

  2. Determination of mercury in seawater by total reflection x-ray fluorescence spectrometry after an electrochemical preconcentration method

    International Nuclear Information System (INIS)

    Ritschel, A.; Chinea Cano, E.; Wobrauschek, P.; Kuntner, C.; Durakbasa, M.N.

    2000-01-01

    A new combined method of electrodeposition of trace elements on metallic plates with subsequent total-reflection x-ray fluorescence spectrometry (TXRF) is proposed for the determination of trace metals in natural waters. The elements of interest are electroplated on highly polished niobium discs which are used as sample carriers for the TXRF measurement. The electrochemical preconcentration is performed in a flow cell under a controlled working electrode potential. The preconcentration step involves only very little manipulation which minimizes the risk of contamination of the sample. The method was investigated by analyzing inorganic mercury in sea water. A detection limit of 7 ngl -1 could be achieved for mercury in a 40 ml sea water sample. (author)

  3. Fish samples as bioindicator of environmental quality: synchrotron radiation total reflection X-ray fluorescence analysis (SR-TXRF)

    Energy Technology Data Exchange (ETDEWEB)

    Vives, Ana Elisa Sirito de [Universidade Metodista de Piracicaba (UNIMEP), Santa Barbara D' Oeste, SP (Brazil). Faculdade de Engenharia, Arquitetura e Urbanismo]. E-mail: aesvives@unimep.br; Moreira, Silvana [Universidade Estadual de Campinas, SP (Brazil). Faculdade de Engenharia, Arquitetura e Urbanismo]. E-mail: Silvana@fec.unicamp.br; Brienza, Sandra Maria Boscolo [Universidade Metodista de Piracicaba (UNIMEP), SP (Brazil). Faculdade de Ciencias Matematicas, da Natureza e de Tecnologia da Informacao]. E-mail: sbrienza@unimep.br; Zucchi, Orgheda Luiza Araujo Domingues [Sao Paulo Univ., Ribeirao Preto, SP (Brazil). Faculdade de Ciencias Farmaceuticas]. E-mail: olzucchi@fcfrp.usp.br; Nascimento Filho, Virgilio Franco do [Centro de Energia Nuclear na Agricultura (CENA), Piracicaba, SP (Brazil)]. E-mail: virgilio@cena.usp.br

    2005-07-01

    In this study fish were used as bioindicators of environmental contamination. The species were collected in Piracicaba River, Sao Paulo state, Brazil and the toxic elements concentrations were determined in muscle tissue and viscus (liver, intestine and stomach) by Synchrotron Radiation Total Reflection X-Ray Fluorescence Analysis (SR-TXRF). Were determined the elements Ti, Cr, Mn, Fe, Ni, Cu, Zn and Ba. The results were compared with values established by Brazilian Legislation for general food. The elements concentrations evidenced potential risk to human health and environmental quality alteration of the studied area. The measurements were realized at the 'Laboratorio Nacional de Luz Sincrotron' (LNLS) located in Campinas, Sao Paulo State, Brazil. (author)

  4. Attenuated total reflectance-FT-IR spectroscopy for gunshot residue analysis: potential for ammunition determination.

    Science.gov (United States)

    Bueno, Justin; Sikirzhytski, Vitali; Lednev, Igor K

    2013-08-06

    The ability to link a suspect to a particular shooting incident is a principal task for many forensic investigators. Here, we attempt to achieve this goal by analysis of gunshot residue (GSR) through the use of attenuated total reflectance (ATR) Fourier transform infrared spectroscopy (FT-IR) combined with statistical analysis. The firearm discharge process is analogous to a complex chemical process. Therefore, the products of this process (GSR) will vary based upon numerous factors, including the specific combination of the firearm and ammunition which was discharged. Differentiation of FT-IR data, collected from GSR particles originating from three different firearm-ammunition combinations (0.38 in., 0.40 in., and 9 mm calibers), was achieved using projection to latent structures discriminant analysis (PLS-DA). The technique was cross (leave-one-out), both internally and externally, validated. External validation was achieved via assignment (caliber identification) of unknown FT-IR spectra from unknown GSR particles. The results demonstrate great potential for ATR-FT-IR spectroscopic analysis of GSR for forensic purposes.

  5. The study of genomic DNA adsorption and subsequent interactions using total internal reflection ellipsometry.

    Science.gov (United States)

    Nabok, Alexei; Tsargorodskaya, Anna; Davis, Frank; Higson, Séamus P J

    2007-10-31

    The adsorption of genomic DNA and subsequent interactions between adsorbed and solvated DNA was studied using a novel sensitive optical method of total internal reflection ellipsometry (TIRE), which combines spectroscopic ellipsometry with surface plasmon resonance (SPR). Single strands of DNA of two species of fish (herring and salmon) were electrostatically adsorbed on top of polyethylenimine films deposited upon gold coated glass slides. The ellipsometric spectra were recorded and data fitting utilized to extract optical parameters (thickness and refractive index) of adsorbed DNA layers. The further adsorption of single stranded DNA from an identical source, i.e. herring ss-DNA on herring ss-DNA or salmon ss-DNA on salmon ss-DNA, on the surface was observed to give rise to substantial film thickness increases at the surface of about 20-21 nm. Conversely adsorption of DNA from alternate species, i.e. salmon ss-DNA on herring ss-DNA or herring ss-DNA on salmon ss-DNA, yielded much smaller changes in thickness of 3-5 nm. AFM studies of the surface roughness of adsorbed layers were in line with the TIRE data.

  6. [Application of Fourier transform attenuated total reflection infrared spectroscopy in analysis of pulp and paper industry].

    Science.gov (United States)

    Zhang, Yong; Cao, Chun-yu; Feng, Wen-ying; Xu, Ming; Su, Zhen-hua; Liu, Xiao-meng; Lü, Wei-jun

    2011-03-01

    As one of the most powerful tools to investigate the compositions of raw materials and the property of pulp and paper, infrared spectroscopy has played an important role in pulp and paper industry. However, the traditional transmission infrared spectroscopy has not met the requirements of the producing processes because of its disadvantages of time consuming and sample destruction. New technique would be needed to be found. Fourier transform attenuated total reflection infrared spectroscopy (ATR-FTIR) is an advanced spectroscopic tool for nondestructive evaluation and could rapidly, accurately estimate the production properties of each process in pulp and paper industry. The present review describes the application of ATR-FTIR in analysis of pulp and paper industry. The analysis processes will include: pulping, papermaking, environmental protecting, special processing and paper identifying.

  7. Determination of copper, iron and zinc in spirituous beverages by total reflection X-ray fluorescence spectrometry

    Science.gov (United States)

    Capote, T.; Marcó, L. M.; Alvarado, J.; Greaves, E. D.

    1999-10-01

    The concentration of copper in traditional homemade alcoholic distillates produced in Venezuela (Cocuy de Penca) were determined by total reflection X-ray fluorescence (TXRF) using vanadium as internal standard. The results were compared to those obtained by flame atomic absorption spectrometry (FAAS). Three preparative methods of addition of vanadium were compared: classical internal standard addition, 'layer on layer' internal standard addition and in situ addition of internal standard. The TXRF procedures were accurate and the precision was comparable to that obtained by the FAAS technique. Copper levels were above the maximum allowed limits for similar beverages. Zinc and iron in commercial and homemade distilled beverages were also analyzed by TXRF with in situ addition of internal standard demonstrating the usefulness of this technique for trace metal determination in distillates.

  8. Development of a novel combined fluorescence and reflectance spectroscopy system for guiding high-grade glioma resections: confirmation of capability in lab experiments

    Science.gov (United States)

    Mousavi, Monirehalsadat; Xie, Haiyan; Xie, Zhiyuan; Brydegaard, Mikkel; Axelsson, Johan; Andersson-Engels, Stefan

    2013-11-01

    Total resection of glioblastoma multiform (GBM), the most common and aggressive malignant brain tumor, is challenging among other things due to difficulty in intraoperative discrimination between normal and residual tumor cells. This project demonstrates the potential of a system based on a combination of autofluorescence and diffuse reflectance spectroscopy to be useful as an intraoperative guiding tool. In this context, a system based on 5 LEDs coupled to optical fibers was employed to deliver UV/visible light to the sample sequentially. Remitted light from the tissue; including diffuse reflected and fluorescence of endogenous and exogenous fluorophores, as well as its photobleaching product, is transmitted to one photodiode and four avalanche photodiodes. This instrument has been evaluated with very promising results by performing various tissue-equivalent phantom laboratory and clinical studies on skin lesions.

  9. Stray light analysis and control

    CERN Document Server

    Fest, Eric

    2013-01-01

    Stray light is defined as unwanted light in an optical system, a familiar concept for anyone who has taken a photograph with the sun in or near their camera's field of view. This book addresses stray light terminology, radiometry, and the physics of stray light mechanisms, such as surface roughness scatter and ghost reflections. The most-efficient ways of using stray light analysis software packages are included. The book also demonstrates how the basic principles are applied in the design, fabrication, and testing phases of optical system development.

  10. Nitrogen deficiency detection using reflected shortwave radiation from irrigated corn canopies

    International Nuclear Information System (INIS)

    Blackmer, T.M.; Schepers, J.S.; Varvel, G.E.; Walter-Shea, E.A.

    1996-01-01

    Techniques that measure the N status of corn (Zea mays L.) can aid in management decisions that have economic and environmental implications. This study was conducted to identify reflected electromagnetic wavelengths most sensitive to detecting N deficiencies in a corn canopy with the possibility for use as a management tool. Reflected shortwave radiation was measured from an irrigated corn N response trial with four hybrids and five N rates at 0, 40, 80, 120, and 160 kg N ha -1 in 1992 and 0, 50, 100, 150, and 200 kg N ha -1 in 1993. A portable spectroradiometer was used to measure reflected radiation (400-1100 nm in 1992, 350-1050 nm in 1993) from corn canopies at approximately the R5 growth stage. Regression analyses revealed that reflected radiation near 550 and 710 nm was superior to reflected radiation near 450 or 650 nm for detecting N deficiencies. The ratio of light reflectance between 550 and 600 nm to light reflectance between 800 and 900 nm also provided sensitive detection of N stress. In 1993, an inexpensive photometric cell, which has peak sensitivity to light centered at 550 nm, was also used to measure reflected radiation from a corn canopy. Photometric cell readings correlated with relative grain yield (P < 0.001, r 2 = 0.74), but more research will be required to develop procedures to account for varying daylight conditions. These results provide information needed for the development of variable-rate fertilizer N application technology. (author)

  11. Exploring the Effects of Cloud Vertical Structure on Cloud Microphysical Retrievals based on Polarized Reflectances

    Science.gov (United States)

    Miller, D. J.; Zhang, Z.; Platnick, S. E.; Ackerman, A. S.; Cornet, C.; Baum, B. A.

    2013-12-01

    A polarized cloud reflectance simulator was developed by coupling an LES cloud model with a polarized radiative transfer model to assess the capabilities of polarimetric cloud retrievals. With future remote sensing campaigns like NASA's Aerosols/Clouds/Ecosystems (ACE) planning to feature advanced polarimetric instruments it is important for the cloud remote sensing community to understand the retrievable information available and the related systematic/methodical limitations. The cloud retrieval simulator we have developed allows us to probe these important questions in a realistically relevant test bed. Our simulator utilizes a polarized adding-doubling radiative transfer model and an LES cloud field from a DHARMA simulation (Ackerman et al. 2004) with cloud properties based on the stratocumulus clouds observed during the DYCOMS-II field campaign. In this study we will focus on how the vertical structure of cloud microphysics can influence polarized cloud effective radius retrievals. Numerous previous studies have explored how retrievals based on total reflectance are affected by cloud vertical structure (Platnick 2000, Chang and Li 2002) but no such studies about the effects of vertical structure on polarized retrievals exist. Unlike the total cloud reflectance, which is predominantly multiply scattered light, the polarized reflectance is primarily the result of singly scattered photons. Thus the polarized reflectance is sensitive to only the uppermost region of the cloud (tau~influencer on the microphysical development of cloud droplets, can be potentially studied with polarimetric retrievals.

  12. Use of gaseous tritium light sources (Beta lights) with respect to nocturnal illumination

    International Nuclear Information System (INIS)

    Solomon, D.E.

    1988-01-01

    A number/letter plate for use in, for example darkened buildings has spaced apart gaseous tritium light sources (beta lights) arranged centrally along the indicia on a reflective background sealed in clear translucent plastics. Uses include house numbers, name plates, telephone numbers, notices, product advertisements, vehicle registration plates and names or trade marks on products. (author)

  13. Synchrotron radiation total reflection x-ray fluorescence analysis; of polymer coated silicon wafers

    International Nuclear Information System (INIS)

    Brehm, L.; Kregsamer, P.; Pianetta, P.

    2000-01-01

    It is well known that total reflection x-ray fluorescence (TXRF) provides an efficient method for analyzing trace metal contamination on silicon wafer surfaces. New polymeric materials used as interlayer dielectrics in microprocessors are applied to the surface of silicon wafers by a spin-coating process. Analysis of these polymer coated wafers present a new challenge for TXRF analysis. Polymer solutions are typically analyzed for bulk metal contamination prior to application on the wafer using inductively coupled plasma mass spectrometry (ICP-MS). Questions have arisen about how to relate results of surface contamination analysis (TXRF) of a polymer coated wafer to bulk trace analysis (ICP-MS) of the polymer solutions. Experiments were done to explore this issue using synchrotron radiation (SR) TXRF. Polymer solutions were spiked with several different concentrations of metals. These solutions were applied to silicon wafers using the normal spin-coating process. The polymer coated wafers were then measured using the SR-TXRF instrument set-up at the Stanford Synchrotron Radiation Laboratory (SSRL). Several methods of quantitation were evaluated. The best results were obtained by developing calibration curves (intensity versus ppb) using the spiked polymer coated wafers as standards. Conversion of SR-TXRF surface analysis results (atoms/cm 2 ) to a volume related concentration was also investigated. (author)

  14. Detection of sibutramine in adulterated dietary supplements using attenuated total reflectance-infrared spectroscopy.

    Science.gov (United States)

    Deconinck, E; Cauwenbergh, T; Bothy, J L; Custers, D; Courselle, P; De Beer, J O

    2014-11-01

    Sibutramine is one of the most occurring adulterants encountered in dietary supplements with slimming as indication. These adulterated dietary supplements often contain a herbal matrix. When customs intercept these kind of supplements it is almost impossible to discriminate between the legal products and the adulterated ones, due to misleading packaging. Therefore in most cases these products are confiscated and send to laboratories for analysis. This results inherently in the confiscation of legal, non-adulterated products. Therefore there is a need for easy to use equipment and techniques to perform an initial screening of samples. Attenuated total reflectance-infrared (ATR-IR) spectroscopy was evaluated for the detection of sibutramine in adulterated dietary supplements. Data interpretation was performed using different basic chemometric techniques. It was found that the use of ATR-IR combined with the k-Nearest Neighbours (k-NN) was able to detect all adulterated dietary supplements in an external test set and this with a minimum of false positive results. This means that a small amount of legal products will still be confiscated and analyzed in a laboratory to be found negative, but no adulterated samples will pass the initial ATR-IR screening. Copyright © 2014 Elsevier B.V. All rights reserved.

  15. Sample preparation for total reflection X-ray fluorescence analysis using resist pattern technique

    Science.gov (United States)

    Tsuji, K.; Yomogita, N.; Konyuba, Y.

    2018-06-01

    A circular resist pattern layer with a diameter of 9 mm was prepared on a glass substrate (26 mm × 76 mm; 1.5 mm thick) for total reflection X-ray fluorescence (TXRF) analysis. The parallel cross pattern was designed with a wall thickness of 10 μm, an interval of 20 μm, and a height of 1.4 or 0.8 μm. This additional resist layer did not significantly increase background intensity on the XRF peaks in TXRF spectra. Dotted residue was obtained from a standard solution (10 μL) containing Ti, Cr, Ni, Pb, and Ga, each at a final concentration of 10 ppm, on a normal glass substrate with a silicone coating layer. The height of the residue was more than 100 μm, where self-absorption in the large residue affected TXRF quantification (intensity relative standard deviation (RSD): 12-20%). In contrast, from a droplet composed of a small volume of solution dropped and cast on the resist pattern structure, the obtained residue was not completely film but a film-like residue with a thickness less than 1 μm, where self-absorption was not a serious problem. In the end, this sample preparation was demonstrated to improve TXRF quantification (intensity RSD: 2-4%).

  16. Attenuated total internal reflection Fourier transform infrared spectroscopy: a quantitative approach for kidney stone analysis.

    Science.gov (United States)

    Gulley-Stahl, Heather J; Haas, Jennifer A; Schmidt, Katherine A; Evan, Andrew P; Sommer, André J

    2009-07-01

    The impact of kidney stone disease is significant worldwide, yet methods for quantifying stone components remain limited. A new approach requiring minimal sample preparation for the quantitative analysis of kidney stone components has been investigated utilizing attenuated total internal reflection Fourier transform infrared spectroscopy (ATR-FT-IR). Calcium oxalate monohydrate (COM) and hydroxylapatite (HAP), two of the most common constituents of urinary stones, were used for quantitative analysis. Calibration curves were constructed using integrated band intensities of four infrared absorptions versus concentration (weight %). The correlation coefficients of the calibration curves range from 0.997 to 0.93. The limits of detection range from 0.07 +/- 0.02% COM/HAP where COM is the analyte and HAP is the matrix, to 0.26 +/- 0.07% HAP/COM where HAP is the analyte and COM is the matrix. This study shows that linear calibration curves can be generated for the quantitative analysis of stone mixtures provided the system is well understood especially with respect to particle size.

  17. Final Technical Report - Polymeric Multilayer Infrared Reflecting Mirrors

    Energy Technology Data Exchange (ETDEWEB)

    Reed, John [3M Company, St. Paul, MN (United States)

    2016-09-16

    The goal of this project was to develop a clear, polymeric, multilayer film with an expanded infrared (IR) reflection band which would allow improved rejection of incident IR energy. The IR reflection band is covering the region from about 850 nm to 1830 nm. This film is essentially clear and colorless in the visible portion of the electromagnetic spectra (visible light transmission of about 89%) while reflecting 90-95% of the IR energy over the portion of the spectra indicated above. This film has a nominal thickness of 3 mils, is polymeric in nature (contains no metals, metal oxides, or other material types) and is essentially clear in appearance This film can then be used as a component of other products such as a solar window film, an IR reflecting interlayer for laminated glass, a heat rejecting skylight film, a base film for daylight redirecting products, a greenhouse film, and many more applications. One of the main strengths of this product is that because it is a standalone IR rejecting film, it can be incorporated and retrofitted into many applications that desire or require the transmission of visible light, but want to block other portions of the solar spectra, especially the IR portion. Many of the applications exist in the window glazing product area where this film can provide for substantial energy improvements in applications where visible light is desired.

  18. Identifying diffraction effects in measured reflectances

    OpenAIRE

    Holzschuch , Nicolas; Pacanowski , Romain

    2015-01-01

    International audience; There are two different physical models connecting the micro-geometry of a surface and its physical reflectance properties (BRDF). The first, Cook-Torrance, assumes geometrical optics: light is reflected and masked by the micro-facets. In this model, the BRDF depends on the probability distribution of micro-facets normals. The second, Church-Takacs, assumes diffraction by the micro-geometry. In this model, the BRDF depends on the power spectral distribution of the surf...

  19. Visual Fatigue Evaluation: Improvement of Reflected Glare on Touch Screen for Nuclear Power Plant

    International Nuclear Information System (INIS)

    Liu, Kang Hung; Yang, Chih Wei; Hwang, Sheue Ling; Liou, Jin Liang

    2014-01-01

    The purpose of this research is to evaluate the visual fatigue of operators caused by glare problems in the main control room of nuclear power plant. Within the limitation in the main control room, reflectors were set under the light source which generates reflected glare on touch screens. Through avoiding the light directly shines on touch screens, reflected glare were eliminated. This research matched up the setting process of reflectors, evaluated the visual fatigue of operators, and collected user's opinions before reflector setting, after the first setting, and after the second setting. The design of reflectors could refer the result of evaluations and the collection of opinions. Nevertheless, the improvement of reflected glare on touch screens could be verified by this evaluations. The result showed that setting reflectors under the light source could eliminate reflected glare effectively, and the visual fatigue was reduced both on subject and object evaluations. However, the setting direction of reflectors has potential effect on operators' visual fatigue, so the real setting of reflectors still need to be evaluated completely. The near point accommodation could reflect the effect of visual fatigue caused by changes of lighting environment. Thus, the verification of new lighting environment according to the near point accommodation is suggested

  20. Some features of light propagation through layers with a complex refractive index

    International Nuclear Information System (INIS)

    Efimov, V.V.; Sementsov, D.I.

    1994-01-01

    By solving Maxwell's equations, expressions are obtained for the energy fluxes both inside and outside a layer with a complex refractive index at normal incidence of light. It is shown that inside the layer, along with fluxes of forward and backward waves, an interference flux can be distinguished whose magnitude is proportional to the imaginary part of the refractive index. A detailed numerical analysis of the energy transmission (T) and reflection (R) coefficients versus the thickness of the layer with negative absorption is performed for normal incidence of light onto the layer surface. Total distribution of the energy flux over the layer thickness is considered both for absorbing and amplifying layers. 13 refs., 4 figs

  1. A comparison of light-coupling into high and low index nanostructured photovoltaic thin films

    Directory of Open Access Journals (Sweden)

    T. Pfadler

    2015-06-01

    Full Text Available Periodically structured electrodes are typically introduced to thin-film photovoltaics for the purpose of light management. Highly effective light-trapping and optimal in-coupling of light is crucial to enhance the overall device performance in such thin-film systems. Here, wavelength-scale structures are transferred via direct laser interference patterning to electron-selective TiO2 electrodes. Two representative thin-film solar cell architectures are deposited on top: an organic solar cell featuring blended P3HT:PCBM as active material, and a hybrid solar cell with Sb2S3 as inorganic active material. A direct correlation in the asymmetry in total absorption enhancement and in structure-induced light in-coupling is spectroscopically observed for the two systems. The structuring is shown to be beneficial for the total absorption enhancement if a high n active material is deposited on TiO2, but detrimental for a low n material. The refractive indices of the employed materials are determined via spectroscopic ellipsometry. The study outlines that the macroscopic Fresnel equations can be used to investigate the spectroscopically observed asymmetry in light in-coupling at the nanostructured TiO2 active material interfaces by visualizing the difference in reflectivity caused by the asymmetry in refractive indices.

  2. Quantification of protein based on single-molecule counting by total internal reflection fluorescence microscopy with adsorption equilibrium

    International Nuclear Information System (INIS)

    Wang Lei; Xu Guang; Shi Zhikun; Jiang Wei; Jin Wenrui

    2007-01-01

    We developed a sensitive single-molecule imaging method for quantification of protein by total internal reflection fluorescence microscopy with adsorption equilibrium. In this method, the adsorption equilibrium of protein was achieved between solution and glass substrate. Then, fluorescence images of protein molecules in a evanescent wave field were taken by a highly sensitive electron multiplying charge coupled device. Finally, the number of fluorescent spots corresponding to the protein molecules in the images was counted. Alexa Fluor 488-labeled goat anti-rat IgG(H + L) was chosen as the model protein. The spot number showed an excellent linear relationship with protein concentration. The concentration linear range was 5.4 x 10 -11 to 8.1 x 10 -10 mol L -1

  3. Slow neutron total cross-section, transmission and reflection calculation for poly- and mono-NaCl and PbF2 crystals

    Science.gov (United States)

    Mansy, Muhammad S.; Adib, M.; Habib, N.; Bashter, I. I.; Morcos, H. N.; El-Mesiry, M. S.

    2016-10-01

    A detailed study about the calculation of total neutron cross-section, transmission and reflection from crystalline materials was performed. The developed computer code is approved to be sufficient for the required calculations, also an excellent agreement has been shown when comparing the code results with the other calculated and measured values. The optimal monochromator and filter parameters were discussed in terms of crystal orientation, mosaic spread, and thickness. Calculations show that 30 cm thick of PbF2 poly-crystal is an excellent cold neutron filter producing neutron wavelengths longer than 0.66 nm needed for the investigation of magnetic structure experiments. While mono-crystal filter PbF2 cut along its (1 1 1), having mosaic spread (η = 0.5°) and thickness 10 cm can only transmit thermal neutrons of the desired wavelengths and suppress epithermal and γ-rays forming unwanted background, when it is cooled to liquid nitrogen temperature. NaCl (2 0 0) and PbF2 (1 1 1) monochromator crystals having mosaic spread (η = 0.5°) and thickness 10 mm shows high neutron reflectivity for neutron wavelengths (λ = 0.114 nm and λ = 0.43 nm) when they used as a thermal and cold neutron monochromators respectively with very low contamination from higher order reflections.

  4. Seasonal variation in the structure of red reflectance of leaves from yellow poplar, red oak, and red maple

    Science.gov (United States)

    Brakke, Thomas W.; Wergin, William P.; Erbe, Eric F.; Harnden, Joann M.

    1993-01-01

    The light scattered from leaves was measured as a function of view angle in the principal plane for yellow poplar, red oak, and red maple. The source was a parallel-polarized helium-neon laser. Yellow poplar leaves had the highest reflectance of the three species, which may have been due to its shorter palisade cells and more extensive spongy mesophyll. Prior to senescence, there was a significant decrease, but not total extinction, in the reflectance of the beam incident at 60 deg from nadir on the adaxial side of the leaves of all three species. Low-temperature SEM observations showed differences in the surface wax patterns among the three species but did not indicate a cause of the reflectance changes other than possibly the accumulation and aging of the wax.

  5. Photonic Crystals: Enhancing the Light Output of Scintillation Based Detectors

    CERN Document Server

    Knapitsch, Arno Richard

    A scintillator is a material which emits light when excited by ionizing radiation. Such materials are used in a diverse range of applications; From high energy particle physics experiments, X-ray security, to nuclear cameras or positron emission tomography. Future high-energy physics (HEP) experiments as well as next generation medical imaging applications are more and more pushing towards better scintillation characteristics. One of the problems in heavy scintillating materials is related to their high index of refraction. As a consequence, most of the scintillation light produced in the bulk material is trapped inside the crystal due to total internal reflection. The same problem also occurs with light emitting diodes (LEDs) and has for a long time been considered as a limiting factor for their overall efficiency. Recent developments in the area of nanophotonics were showing now that those limitations can be overcome by introducing a photonic crystal (PhC) slab at the outcoupling surface of the substrate. P...

  6. Reduction of short wavelength reflectance of multi-wall carbon nanotubes through ultraviolet laser irradiation

    Science.gov (United States)

    Stephens, Michelle S.; Simonds, Brian J.; Yung, Christopher S.; Conklin, Davis; Livigni, David J.; Oliva, Alberto Remesal; Lehman, John H.

    2018-05-01

    Multi-wall carbon nanotube coatings are used as broadband, low-reflectance absorbers for bolometric applications and for stray light control. They are also used as high emittance blackbody radiators. Irradiation of single wall carbon nanotubes with ultraviolet (UV) laser light has been shown to remove amorphous carbon debris, but there have been few investigations of the interaction of UV light with the more complex physics of multi-wall carbon nanotubes. We present measurements of reflectance and surface morphology before and after exposure of multi-wall carbon nanotube coatings to 248 nm UV laser light. We show that UV exposure reduces the reflectivity at wavelengths below 600 nm and present modeling of the thermal cycling the UV exposure causes at the surface of the carbon nanotubes. This effect can be used to flatten the spectral shape of the reflectivity curve of carbon nanotube absorber coatings used for broadband applications. Finally, we find that the effect of UV exposure depends on the nanotube growth process.

  7. The monitoring system using laser light for the patient movement during radiation therapy

    International Nuclear Information System (INIS)

    Sano, Naoki; Onishi, Hiroshi; Yamaguchi, Motoshi; Kuriyama, Kengo; Akiyama, Saburou; Nakamura, Osamu; Araki, Tsutomu

    1997-01-01

    Purpose: The purpose of this study is to evaluate the usefulness of a newly developed real-time patient movement monitoring system built into the patient positioning light from the frontal and horizontal view. Materials and Techniques: This system is composed of 4 parts. They are a laser light projector, a retro-reflected tape, a sensor of photo-diode, and an alarm devise. First, this system projects a laser light for the patient movement monitor into the center of the crossed lines of the patient positioning light. The laser light (a diameter of 1.5mm and power of 0.5mW) for the patient movement monitor has a different wave length(633nm) from the patient positioning light. Then it is reflected into the direction of incidence with a retro-reflection tape affixed on three patient positioning points. And the system has a photo-diode which can sense the reflected laser light. This retro-reflected tape is made of tiny high reflective beads of glass which is fixed on a sheet with the thickness of 0.12mm and is able to be cut into any shape. This has a maximum retro-reflection angle of 70 degrees. We can select a tolerance of the patient movement by changing its shape and size. A buzzer strikes and a lamp is turned on to alarm for the error when the retro-reflected laser light is not sensed with the photo-diode. Results: The real-time monitoring accuracy of this system is only 0.17mm in the dimension of error for a selected tolerance of the phantom examination. Conclusion: This patient positioning system can be made simply and inexpensively and has a high monitoring accuracy. We can apply this system for a high-precision irradiation such as the three dimensional irradiation and small target irradiation

  8. Rapid determination of free fatty acid content in waste deodorizer distillates using single bounce-attenuated total reflectance-FTIR spectroscopy.

    Science.gov (United States)

    Naz, Saba; Sherazi, Sayed Tufail Hussain; Talpur, Farah N; Mahesar, Sarfaraz A; Kara, Huseyin

    2012-01-01

    A simple, rapid, economical, and environmentally friendly analytical method was developed for the quantitative assessment of free fatty acids (FFAs) present in deodorizer distillates and crude oils by single bounce-attenuated total reflectance-FTIR spectroscopy. Partial least squares was applied for the calibration model based on the peak region of the carbonyl group (C=O) from 1726 to 1664 cm(-1) associated with the FFAs. The proposed method totally avoided the use of organic solvents or costly standards and could be applied easily in the oil processing industry. The accuracy of the method was checked by comparison to a conventional standard American Oil Chemists' Society (AOCS) titrimetric procedure, which provided good correlation (R = 0.99980), with an SD of +/- 0.05%. Therefore, the proposed method could be used as an alternate to the AOCS titrimetric method for the quantitative determination of FFAs especially in deodorizer distillates.

  9. Circadian light

    Directory of Open Access Journals (Sweden)

    Bierman Andrew

    2010-02-01

    Full Text Available Abstract The present paper reflects a work in progress toward a definition of circadian light, one that should be informed by the thoughtful, century-old evolution of our present definition of light as a stimulus for the human visual system. This work in progress is based upon the functional relationship between optical radiation and its effects on nocturnal melatonin suppression, in large part because the basic data are available in the literature. Discussed here are the fundamental differences between responses by the visual and circadian systems to optical radiation. Brief reviews of photometry, colorimetry, and brightness perception are presented as a foundation for the discussion of circadian light. Finally, circadian light (CLA and circadian stimulus (CS calculation procedures based on a published mathematical model of human circadian phototransduction are presented with an example.

  10. Generalized laws of reflection and refraction from transformation optics

    OpenAIRE

    Xu, Yadong; Yao, Kan; Chen, Huanyang

    2012-01-01

    Based on transformation optics, we introduce another set of generalized laws of reflection and refraction (differs from that of [Science 334, 333 (2011)]), through which a transformation media slab is derived as a meta-surface, producing anomalous reflection and refraction for all polarizations of incident light.

  11. Glue Film Thickness Measurements by Spectral Reflectance

    International Nuclear Information System (INIS)

    Marshall, B.R.

    2010-01-01

    Spectral reflectance was used to determine the thickness of thin glue layers in a study of the effect of the glue on radiance and reflectance measurements of shocked-tin substrates attached to lithium fluoride windows. Measurements based on profilometry of the components were found to be inaccurate due to flatness variations and deformation of the tin substrate under pressure during the gluing process. The accuracy of the spectral reflectance measurements were estimated to be ±0.5 (micro)m, which was sufficient to demonstrate a convincing correlation between glue thickness and shock-generated light.

  12. Glue Film Thickness Measurements by Spectral Reflectance

    Energy Technology Data Exchange (ETDEWEB)

    B. R. Marshall

    2010-09-20

    Spectral reflectance was used to determine the thickness of thin glue layers in a study of the effect of the glue on radiance and reflectance measurements of shocked-tin substrates attached to lithium fluoride windows. Measurements based on profilometry of the components were found to be inaccurate due to flatness variations and deformation of the tin substrate under pressure during the gluing process. The accuracy of the spectral reflectance measurements were estimated to be ±0.5 μm, which was sufficient to demonstrate a convincing correlation between glue thickness and shock-generated light.

  13. Thin films for the manipulation of light

    International Nuclear Information System (INIS)

    Piegari, Angela; Sytchkova, Anna

    2015-01-01

    The manipulation of light is typically accomplished by a series of optical surfaces on which the incident beam is reflected, or through which the beam is transmitted. Thin film coatings help to modify the behavior of such surfaces for obtaining the desired result: antireflection coatings to reduce reflection losses, high-reflectance mirrors, filters to divide or combine beams of different wavelengths, and many other types. The amount of light that is transmitted or reflected depends on the optical parameters of the materials and on interference phenomena in thin-film structures. Dedicated software is available to design the proper coating for each requirement. There are several applications of optical thin films, many of them are useful in the everyday life, many others are dedicated to scientific purposes, as will be described in this paper [it

  14. Polarization Of Light In The Natural Environment

    Science.gov (United States)

    Coulson, Kinsell L.

    1990-01-01

    This paper provides a characterization of the fields of light polarization with which the optical designer or user of optical devices in the natural environment must be concerned. After a brief historical outline of the principal developments in polarization theory and observations during the last two centuries, the main emphasis is on the two primary processes responsible for the polarization of light in nature--scattering of light by particles of the atmosphere and reflection from soils, vegetation, snow, and water at the earth's surface. Finally, a seven minute film on polarization effects which can be seen in everyday surroundings will be shown. Scattering by atmospheric particles is responsible for high values of polarization in various atmospheric conditions and at certain scattering geometries. Such scattering particles include molecules of the atmospheric gases, aerosols of dust, haze, and air pollution, water droplets of fog and clouds, and the ice crystals of cirrus. It is seen that development of the theory of scattering by such particles has outstripped the measurements necessary for validation of the theory, a fact which points up the importance of symposia such as the present one. The reverse is true, however, for the polarizing properties of natural surfaces. Only in the case of still water is the theory of reflection adequate to characterize in a quantitative fashion the polarizing effects produced by the reflection of light from such natural surfaces. Polarization of light by reflection from vegetation is of prime importance in a remote sensing context, but much further work is needed to characterize vegetative reflectance for the purpose. The short film on polarization effects provides a good visualization technique and training aid for students interested in the field.

  15. Worldwide distribution of Total Reflection X-ray Fluorescence instrumentation and its different fields of application: A survey

    Energy Technology Data Exchange (ETDEWEB)

    Klockenkämper, Reinhold, E-mail: reinhold.klockenkaemper@isas.de; Bohlen, Alex von

    2014-09-01

    A survey was carried out with users and manufacturers of Total Reflection X-ray Fluorescence instrumentation in order to demonstrate the worldwide distribution of TXRF equipment and the different fields of applications. In general, TXRF users come from universities and scientific institutes, from working places at synchrotron beam-lines, or laboratories in semiconductor fabs. TXRF instrumentation is distributed in more than 50 countries on six continents and is applied at about 200 institutes and laboratories. The number of running desktop instruments amounts to nearly 300 units. About 60 beamlines run working places dedicated to TXRF. About 300 floor-mounted instruments are estimated to be used in about 150 fabs of the semiconductor industry. In total, 13 different fields of applications could be registered statistically from three different aspects. - Highlights: • According to the survey world maps show the distribution of TXRF equipment. • Nearly 700 individual units are running actually in 57 countries of 6 continents. • Users work at 200 universities, 60 synchrotron-beamlines, and 150 semiconductor fabs. • 13 fields of applications (e.g. environmental, chemical) are evaluated statistically. • Manufacturers, conference members and authors lead to 3 different pie-charts.

  16. Versatile microfluidic total internal reflection (TIR)-based devices: application to microbeads velocity measurement and single molecule detection with upright and inverted microscope.

    Science.gov (United States)

    Le, Nam Cao Hoai; Yokokawa, Ryuji; Dao, Dzung Viet; Nguyen, Thien Duy; Wells, John C; Sugiyama, Susumu

    2009-01-21

    A poly(dimethylsiloxane) (PDMS) chip for Total Internal Reflection (TIR)-based imaging and detection has been developed using Si bulk micromachining and PDMS casting. In this paper, we report the applications of the chip on both inverted and upright fluorescent microscopes and confirm that two types of sample delivery platforms, PDMS microchannel and glass microchannel, can be easily integrated depending on the magnification of an objective lens needed to visualize a sample. Although any device configuration can be achievable, here we performed two experiments to demonstrate the versatility of the microfluidic TIR-based devices. The first experiment was velocity measurement of Nile red microbeads with nominal diameter of 500 nm in a pressure-driven flow. The time-sequenced fluorescent images of microbeads, illuminated by an evanescent field, were cross-correlated by a Particle Image Velocimetry (PIV) program to obtain near-wall velocity field of the microbeads at various flow rates from 500 nl/min to 3000 nl/min. We then evaluated the capabilities of the device for Single Molecule Detection (SMD) of fluorescently labeled DNA molecules from 30 bp to 48.5 kbp and confirm that DNA molecules as short as 1105 bp were detectable. Our versatile, integrated device could provide low-cost and fast accessibility to Total Internal Reflection Fluorescent Microscopy (TIRFM) on both conventional upright and inverted microscopes. It could also be a useful component in a Micro-Total Analysis System (micro-TAS) to analyze nanoparticles or biomolecules near-wall transport or motion.

  17. Slow-light pulses in moving media

    International Nuclear Information System (INIS)

    Fiurasek, J.; Leonhardt, U.; Parentani, R.

    2002-01-01

    Slow light in moving media reaches a counterintuitive regime when the flow speed of the medium approaches the group velocity of light. Pulses can penetrate a region where a counterpropagating flow exceeds the group velocity. When the counterflow slows down, pulses are reflected

  18. Light trespass : causes, remedies and actions. Paper presented at the CIE / MBE Symposium "Lighting and Signalling for Transport", Budapest, 22-23 September 1986.

    NARCIS (Netherlands)

    Schreuder, D.A.

    1986-01-01

    Light trespass is the result of light that does not reach its destination, or that is reflected after having reached its destination or is scattered by the media in between source and destination: by light that is "spilled". Light trespass may disturb people for whom the lighting actually is

  19. Diffuse reflectance spectroscopy for monitoring diabetic foot ulcer - A pilot study

    Science.gov (United States)

    Anand, Suresh; Sujatha, N.; Narayanamurthy, V. B.; Seshadri, V.; Poddar, Richa

    2014-02-01

    Foot ulceration due to diabetes mellitus is a major problem affecting 12-25% of diabetic subjects in their lifetime. An untreated ulcer further gets infected which causes necrosis leading to amputation of lower extremities. Early identification of risk factors and treatment for these chronic wounds would reduce health care costs and improve the quality of life for people with diabetes. Recent clinical investigations have shown that a series of factors including reduced oxygen delivery and disturbed metabolism have been observed on patients with foot ulceration due to diabetes. Also, these factors can impair the wound healing process. Optical techniques based on diffuse reflectance spectroscopy provide characteristic spectral finger prints shed light on tissue oxygenation levels and morphological composition of a tissue. This study deals with the application of diffuse reflectance intensity ratios based on oxyhemoglobin bands (R542/R580), ratios of oxy- and deoxy-hemoglobin bands (R580/R555), total hemoglobin concentration and hemoglobin oxygen saturation between normal and diabetic foot ulcer sites. Preliminary results obtained are found to be promising indicating the application of reflectance spectroscopy in the assessment of foot ulcer healing.

  20. Prediction of purine derivatives, creatinine and total nitrogen concentrations in urine by FT-Near-lnfrared Reflectance spectroscopy (FT-NIR)

    International Nuclear Information System (INIS)

    Susmel, P.; Piani, B.; Toso, B.; Stefanon, B.

    2004-01-01

    The objective of this study was to provide an alternative method for the determination of purine derivatives (PD, which include allantoin, uric acid, hypoxanthine and xanthine), creatinine and total nitrogen (N) concentrations in urine. About 180 urine samples from cattle, buffaloes and rabbit were collected and analyzed for PD by HPLC, creatinine by spectrophotometry and N by Kjeldahl method. The urine samples were then analyzed by Fourier Transformed Near Infrared Reflectance Spectroscopy (FT-NIR) to find conformity between this technique and the HPLC and colorimetric methods. FT-NIR can predict allantoin, uric acid, hypoxanthine, xanthine, creatinine, total N and sum of N in both allantoin and uric acid with a satisfactory level of accuracy: the determination coefficient (r 2 ) of validation ranged from 0.888% for uric acid to 0.982% for total N. The coefficients of determination for allantoin, creatinine and sum of N in both allantoin and uric acid were 0.92, 0.894 and 0.90%, respectively. Hypoxanthine and xanthine in urine samples were not detectable by NIRS, probably because of their low concentrations, and therefore they were not considered for instrumental calibration. (author)

  1. Analysis of H2O in silicate glass using attenuated total reflectance (ATR) micro-FTIR spectroscopy

    Science.gov (United States)

    Lowenstern, Jacob B.; Pitcher, Bradley W.

    2013-01-01

    We present a calibration for attenuated total reflectance (ATR) micro-FTIR for analysis of H2O in hydrous glass. A Ge ATR accessory was used to measure evanescent wave absorption by H2O within hydrous rhyolite and other standards. Absorbance at 3450 cm−1 (representing total H2O or H2Ot) and 1630 cm−1 (molecular H2O or H2Om) showed high correlation with measured H2O in the glasses as determined by transmission FTIR spectroscopy and manometry. For rhyolite, wt%H2O=245(±9)×A3450-0.22(±0.03) and wt%H2Om=235(±11)×A1630-0.20(±0.03) where A3450 and A1630 represent the ATR absorption at the relevant infrared wavelengths. The calibration permits determination of volatiles in singly polished glass samples with spot size down to ~5 μm (for H2O-rich samples) and detection limits of ~0.1 wt% H2O. Basaltic, basaltic andesite and dacitic glasses of known H2O concentrations fall along a density-adjusted calibration, indicating that ATR is relatively insensitive to glass composition, at least for calc-alkaline glasses. The following equation allows quantification of H2O in silicate glasses that range in composition from basalt to rhyolite: wt%H2O=(ω×A3450/ρ)+b where ω = 550 ± 21, b = −0.19 ± 0.03, ρ = density, in g/cm3, and A3450 is the ATR absorbance at 3450 cm−1. The ATR micro-FTIR technique is less sensitive than transmission FTIR, but requires only a singly polished sample for quantitative results, thus minimizing time for sample preparation. Compared with specular reflectance, it is more sensitive and better suited for imaging of H2O variations in heterogeneous samples such as melt inclusions. One drawback is that the technique can damage fragile samples and we therefore recommend mounting of unknowns in epoxy prior to polishing. Our calibration should hold for any Ge ATR crystals with the same incident angle (31°). Use of a different crystal type or geometry would require measurement of several H2O-bearing standards to provide a crystal

  2. Zinc vanadate nanorods and their visible light photocatalytic activity

    International Nuclear Information System (INIS)

    Pei, L.Z.; Lin, N.; Wei, T.; Liu, H.D.; Yu, H.Y.

    2015-01-01

    Highlights: • Zinc vanadate nanorods have been synthesized by a facile hydrothermal process. • The size of zinc vanadate nanorods can be controlled by growth conditions. • Zinc vanadate nanorods show good photocatalytic activities of methylene blue under solar light. - Abstract: Zinc vanadate nanorods have been synthesized by a simple hydrothermal process using zinc acetate and sodium vanadate as the raw materials. The zinc vanadate nanorods have been characterized by X-ray diffraction (XRD), scanning electron microscopy (SEM), transmission electron microscopy (TEM), high-resolution TEM (HRTEM) and solid UV–vis diffuse reflectance spectrum. XRD pattern and HRTEM image show that the zinc vanadate nanorods are composed of single crystalline monoclinic Zn 2 V 2 O 7 phase. SEM and TEM observations show that the diameter and length of the zinc vanadate nanorods are 50–100 nm and about 5 μm, respectively. Sodium dodecyl sulfonate (SDS) has an essential role in the formation of zinc vanadate nanorods. The SDS-assisted nucleation and growth process have been proposed to explain the formation and growth of the zinc vanadate nanorods. Solid UV–vis diffuse reflectance spectrum shows that the zinc vanadate nanorods have a band gap of 2.76 eV. The photocatalytic activities of the zinc vanadate nanorods have been evaluated by the photocatalytic degradation of methylene blue (MB) under solar light irradiation. The MB with the concentration of 10 mg L −1 can be degraded totally under the solar light irradiation for 4 h. It is suggested that the zinc vanadate nanorods exhibit promising application potential for the degradation of organic pollutants under solar light irradiation

  3. Surface reflectance of Antarctic bryophytes and protection from UV and visible light

    International Nuclear Information System (INIS)

    Robinson, S.A.; Wasley, J.; Turnbull, J.

    2000-01-01

    Full text: As well as determining the amount of solar radiation available for photosynthesis, the surface reflectance and absorptance characteristics of plants are their first defence against damaging effects of solar radiation. The solar spectrum can be damaging to plants in many ways. At shorter wavelengths, UV-B (280-320 nm) radiation can cause lesions in nucleic acid and proteins. Excess levels of visible radiation (400-750) can cause photoinhibition whilst high absorbtance of longer wavelengths (>750) leads to increases in temperature that can be detrimental in some environments. The adaptation of surface reflectance properties of vascular plants to particular environments are well known in some ecosystems. For example in desert ecosystems pubescent leaf surfaces that increase reflectance are common and have been demonstrated to be important to protection from photoinhibition. The epidermal characteristics of some plants are also known to change in absorptance, due to the accumulation of specific compounds. For example flavonoids which are effective screens against UV-B radiation, increase upon exposure to UV-B radiation. In this study we surveyed the natural variability in surface reflectance in mosses growing in continental Antarctica. Antarctica is experiencing large increases in incident UV-B radiation due to reductions in concentrations of stratospheric ozone. Additionally over the summer months (November January), when moss is exposed to direct sunlight, levels of visible solar radiation are also high, increasing the likelihood of photoinhibitory damage in moss. Our aim in this study is to describe the natural variability in the surface reflectance characteristics of moss, such that we have a baseline with which to assess future changes in response to changes in global climate, and imposed experimental treatments, and also to develop hypotheses with respect to how mosses have adapted to the cold and arid antarctic environment. Variability in surface

  4. Ultraviolet (UV)-reflective paint with ultraviolet germicidal irradiation (UVGI) improves decontamination of nosocomial bacteria on hospital room surfaces.

    Science.gov (United States)

    Jelden, Katelyn C; Gibbs, Shawn G; Smith, Philip W; Hewlett, Angela L; Iwen, Peter C; Schmid, Kendra K; Lowe, John J

    2017-06-01

    An ultraviolet germicidal irradiation (UVGI) generator (the TORCH, ClorDiSys Solutions, Inc.) was used to compare the disinfection of surface coupons (plastic from a bedrail, stainless steel, and chrome-plated light switch cover) in a hospital room with walls coated with ultraviolet (UV)-reflective paint (Lumacept) or standard paint. Each surface coupon was inoculated with methicillin-resistant Staphylococcus aureus (MRSA) or vancomycin-resistant Enterococcus faecalis (VRE), placed at 6 different sites within a hospital room coated with UV-reflective paint or standard paint, and treated by 10 min UVC exposure (UVC dose of 0-688 mJ/cm 2 between sites with standard paint and 0-553 mJ/cm 2 with UV-reflective paint) in 8 total trials. Aggregated MRSA concentrations on plastic bedrail surface coupons were reduced on average by 3.0 log 10 (1.8 log 10 Geometric Standard Deviation [GSD]) with standard paint and 4.3 log 10 (1.3 log 10 GSD) with UV-reflective paint (p = 0.0005) with no significant reduction differences between paints on stainless steel and chrome. Average VRE concentrations were reduced by ≥4.9 log 10 (surface types with UV-reflective paint and ≤4.1 log 10 (hospital bed from the UVGI generator, MRSA concentrations on average were reduced by 1.3 log 10 (1.7 log 10 GSD) with standard paint and 4.7 log 10 (1.3 log 10 GSD) with UV-reflective paint (p hospital room walls with UV-reflective paint enhanced UVGI disinfection of nosocomial bacteria on various surfaces compared to standard paint, particularly at a surface placement site indirectly exposed to UVC light.

  5. An Evaluation of the Instruction Carried out with Printed Laboratory Materials Designed in Accordance with 5E Model: Reflection of Light and Image on a Plane Mirror

    Science.gov (United States)

    Ayvaci, Hakan Sevki; Yildiz, Mehmet; Bakirci, Hasan

    2015-01-01

    This study employed a print laboratory material based on 5E model of constructivist learning approach to teach reflection of light and Image on a Plane Mirror. The effect of the instruction which conducted with the designed print laboratory material on academic achievements of prospective science and technology teachers and their attitudes towards…

  6. Total-reflection x-ray fluorescence with a brillant undulator x-ray source

    International Nuclear Information System (INIS)

    Sakurai, K.; Eba, H.; Numako, C.; Suzuki, M.; Inoue, K.; Yagi, N.

    2000-01-01

    Total-reflection x-ray fluorescence (TXRF) is a highly sensitive technique for analyzing trace elements, because of the very low background from the sample support. Use of third-generation synchrotron x-ray source could further enhance the detection power. However, while such high sensitivity permits the detection of signals from trace elements of interest, it also means that one can observe weak parasitic x-rays as well. If the sample surface becomes even slightly contaminated, owing to air particulates near the beamline, x-ray fluorescence lines of iron, zinc, copper, nickel, chromium, and titanium can be observed even for a blank sample. Another critical problem is the low-energy-side tail of the scattering x-rays, which ultimately restricts the detection capability of the technique using a TXRF spectrometer based on a Si(Li) detector. The present paper describes our experiments with brilliant undulator x-ray beams at BL39XU and BL40XU, at the SPring-8, Harima, Japan. The emphasis is on the development of instruments to analyze a droplet of 0.1 μl containing trace elements of ppb level. Although the beamline is not a clean room, we have employed equipment for preparing a clean sample and also for avoiding contamination during transferring the sample into the spectrometer. We will report on the successful detection of the peak from 0.8 ppb selenium in a droplet (absolute amount 80 fg). We will also present the results of recent experiments obtained from a Johansson spectrometer rather than a Si(Li) detector. (author)

  7. Total reflection X-ray fluorescence analysis of airborne silver nanoparticles from fabrics.

    Science.gov (United States)

    Menzel, Magnus; Fittschen, Ursula Elisabeth Adriane

    2014-03-18

    Ag nanoparticles (NPs) are usually applied to consumer products because of their antimicrobial properties, which are desired in fabrics for sportswear as well as cloth used for cleaning. Hazards to human health from airborne Ag NPs may occur when the NPs are inhaled. NPs are comparable in size to macromolecules and viruses and able to penetrate deep into the lungs, e.g., the alveoli, where they may cause damage to cells and tissue due to their large surface area. In this study, aerosols released form fabrics treated with Ag NPs were collected using a low pressure Berner impactor and analyzed with total reflection X-ray fluorescence (TXRF). We found that the Ag NPs are released primarily in the form of larger particles, mainly 0.13-2 μm, probably attached to fiber material. Using an electron micro probe, single particles could be identified. The detection of backscattered electrons suggests small spots on the particle consist of a heavier element, which most likely is Ag, although the signal in energy-dispersive X-ray spectroscopy (EDX) was below the lower limit of detection (LOD). To achieve LODs necessary for Ag determination, Ar peaks were eliminated by a nitrogen atmosphere provided by the "Picofox-box". This enables linear calibration and quantification of Ag. The LOD was calculated at 0.2 ng (2.0 ppb). Following the TXRF and scanning electron microscopy (SEM)/EDX analysis, the aerosol samples were dissolved in nitric acid and analyzed with ICPMS to successfully confirm the results obtained by the TXRF measurements.

  8. Light source distribution and scattering phase function influence light transport in diffuse multi-layered media

    Science.gov (United States)

    Vaudelle, Fabrice; L'Huillier, Jean-Pierre; Askoura, Mohamed Lamine

    2017-06-01

    Red and near-Infrared light is often used as a useful diagnostic and imaging probe for highly scattering media such as biological tissues, fruits and vegetables. Part of diffusively reflected light gives interesting information related to the tissue subsurface, whereas light recorded at further distances may probe deeper into the interrogated turbid tissues. However, modelling diffusive events occurring at short source-detector distances requires to consider both the distribution of the light sources and the scattering phase functions. In this report, a modified Monte Carlo model is used to compute light transport in curved and multi-layered tissue samples which are covered with a thin and highly diffusing tissue layer. Different light source distributions (ballistic, diffuse or Lambertian) are tested with specific scattering phase functions (modified or not modified Henyey-Greenstein, Gegenbauer and Mie) to compute the amount of backscattered and transmitted light in apple and human skin structures. Comparisons between simulation results and experiments carried out with a multispectral imaging setup confirm the soundness of the theoretical strategy and may explain the role of the skin on light transport in whole and half-cut apples. Other computational results show that a Lambertian source distribution combined with a Henyey-Greenstein phase function provides a higher photon density in the stratum corneum than in the upper dermis layer. Furthermore, it is also shown that the scattering phase function may affect the shape and the magnitude of the Bidirectional Reflectance Distribution (BRDF) exhibited at the skin surface.

  9. Developing a composite weighted quality metric to reflect the total benefit conferred by a health plan.

    Science.gov (United States)

    Taskler, Glen B; Braithwaite, R Scott

    2015-03-01

    To improve individual health quality measures, which are associated with varying degrees of health benefit, and composite quality metrics, which weight individual measures identically. We developed a health-weighted composite quality measure reflecting the total health benefit conferred by a health plan annually, using preventive care as a test case. Using national disease prevalence, we simulated a hypothetical insurance panel of individuals aged 25 to 84 years. For each individual, we estimated the gain in life expectancy associated with 1 year of health system exposure to encourage adherence to major preventive care guidelines, controlling for patient characteristics (age, race, gender, comorbidity) and variation in individual adherence rates. This personalized gain in life expectancy was used to proxy for the amount of health benefit conferred by a health plan annually to its members, and formed weights in our health-weighted composite quality measure. We aggregated health benefits across the health insurance membership panel to analyze total health system performance. Our composite quality metric gave the highest weights to health plans that succeeded in implementing tobacco cessation and weight loss. One year of compliance with these goals was associated with 2 to 10 times as much health benefit as compliance with easier-to-follow preventive care services, such as mammography, aspirin, and antihypertensives. For example, for women aged 55 to 64 years, successful interventions to encourage weight loss were associated with 2.1 times the health benefit of blood pressure reduction and 3.9 times the health benefit of increasing adherence with screening mammography. A single health-weighted quality metric may inform measurement of total health system performance.

  10. Enhancement of white light OLED efficiency by combining both internal and external light extraction structures

    Science.gov (United States)

    Kao, I.-Ling; Ku, Chun-Neng; Chen, Yi-Ping; Lin, Ding-Zheng

    2012-09-01

    We proposed an internal nanostructure with a high reflective index planarization layer to solve the optical loss due to the reflective index mismatch between ITO and glass substrate. In our experiments, we found the electrical property of OLED device was significantly influenced by the internal nanostructures without planarization layer. Moreover, the internal extraction structure (IES) is not necessarily beneficial for light extraction. Therefore, we proposed a new substrate combine both internal and external extraction structure (EES) to extract trapping light. We successfully developed a high refractive index (N 1.7) planarization material with flat surface (RMS roughness < 2 nm), and improved about 70% device efficiency compared to traditional glass substrate.

  11. Determination of lead in clay enameled by X-ray fluorescence technique in Total reflection and by Scanning Electron Microscopy; Determinacion de plomo en esmaltado de barro por Fluorescencia de rayos X en reflexion total y Microscopia Electronica de Barrido

    Energy Technology Data Exchange (ETDEWEB)

    Zarazua O, G.; Carapia M, L. [Instituto Nacional de Investigaciones Nucleares, C.P. 52045 Estado de Mexico (Mexico)

    2000-07-01

    This work has the objective of determining lead free in the glazed commercial stewing pans using the X-ray fluorescence technique in Total reflection (FRX) and the observation and semiquantitative determination of lead by Analytical Scanning Electron Microscopy (ASEM). (Author)

  12. Effect of the refraction factor of a plastic fiber shell on the internal reflection coefficient

    International Nuclear Information System (INIS)

    Pkrksypkin, A.I.; Ponomarev, L.I.

    1992-01-01

    Results of pilot studies of the effect of refraction factor of plastic fiber shell on the coefficient of light internal reflection in the fiber are presented. It is pointed, that the shell does not absorb the light, but effects the surface layer of the fiber centre so, that dependence of the coefficient of internal reflection on refraction factor of the shell may be described using Fresnel formulae. It is shown, that coefficient of internal reflection decreases with the increase of refraction factor. Technique to determine volume length of scintillation light absorption in the fiber is suggested

  13. Reflection-type electromagnetically induced transparency analogue in terahertz metamaterials

    International Nuclear Information System (INIS)

    Ding Chun-Feng; Zhang Ya-Ting; Yao Jian-Quan; Xu De-Gang; Zhang Gui-Zhong; Sun Chong-Ling

    2014-01-01

    A reflection-type electromagnetically induced transparency (EIT) metamaterial is proposed, which is composed of a dielectric spacer sandwiched with metallic patterns and metallic plane. Experimental results of THz time domain spectrum (THz-TDS) exhibit a typical reflection of EIT at 0.865 THz, which are in excellent agreement with the full-wave simulations. A multi-reflection theory is adopted to analyze the physical mechanism of the reflection-type EIT, showing that the reflection-type EIT is a superposition of multiple reflection of the transmission EIT. Such a reflection-type EIT provides many applications based on the EIT effect, such as slow light devices and nonlinear elements. (electromagnetism, optics, acoustics, heat transfer, classical mechanics, and fluid dynamics)

  14. Reflectance, illumination, and appearance in color constancy.

    Science.gov (United States)

    McCann, John J; Parraman, Carinna; Rizzi, Alessandro

    2014-01-01

    We studied color constancy using a pair of identical 3-D Color Mondrian displays. We viewed one 3-D Mondrian in nearly uniform illumination, and the other in directional, nonuniform illumination. We used the three dimensional structures to modulate the light falling on the painted surfaces. The 3-D structures in the displays were a matching set of wooden blocks. Across Mondrian displays, each corresponding facet had the same paint on its surface. We used only 6 chromatic, and 5 achromatic paints applied to 104 block facets. The 3-D blocks add shadows and multiple reflections not found in flat Mondrians. Both 3-D Mondrians were viewed simultaneously, side-by-side. We used two techniques to measure correlation of appearance with surface reflectance. First, observers made magnitude estimates of changes in the appearances of identical reflectances. Second, an author painted a watercolor of the 3-D Mondrians. The watercolor's reflectances quantified the changes in appearances. While constancy generalizations about illumination and reflectance hold for flat Mondrians, they do not for 3-D Mondrians. A constant paint does not exhibit perfect color constancy, but rather shows significant shifts in lightness, hue and chroma in response to the structure in the nonuniform illumination. Color appearance depends on the spatial information in both the illumination and the reflectances of objects. The spatial information of the quanta catch from the array of retinal receptors generates sensations that have variable correlation with surface reflectance. Models of appearance in humans need to calculate the departures from perfect constancy measured here. This article provides a dataset of measurements of color appearances for computational models of sensation.

  15. Reflectance, illumination, and appearance in color constancy

    Directory of Open Access Journals (Sweden)

    John J. McCann

    2014-01-01

    Full Text Available We studied color constancy using a pair of identical 3-D Color Mondrian displays. We viewed one 3-D Mondrian in nearly uniform illumination, and the other in directional, nonuniform illumination. We used the three dimensional structures to modulate the light falling on the painted surfaces. The 3-D structures in the displays were a matching set of wooden blocks. Across Mondrian displays, each corresponding facet had the same paint on its surface. We used only 6 chromatic, and 5 achromatic paints applied to 104 block facets. The 3-D blocks add shadows and multiple reflections not found in flat Mondrians. Both 3-D Mondrians were viewed simultaneously, side-by-side. We used two techniques to measure correlation of appearance with surface reflectance. First, observers made magnitude estimates of changes in the appearances of identical reflectances. Second, an author painted a watercolor of the 3-D Mondrians. The watercolor’s reflectances quantified the changes in appearances. While constancy generalizations about illumination and reflectance hold for flat Mondrians, they do not for 3-D Mondrians. A constant paint does not exhibit perfect color constancy, but rather shows significant shifts in lightness, hue and chroma in response to the structure in the nonuniform illumination. Color appearance depends on the spatial information in both the illumination and the reflectances of objects. The spatial information of the quanta catch from the array of retinal receptors generates sensations that have variable correlation with surface reflectance. Models of appearance in humans need to calculate the departures from perfect constancy measured here. This article provides a dataset of measurements of color appearances for computational models of sensation.

  16. Illumination of interior spaces by bended hollow light guides: Application of the theoretical light propagation method

    Energy Technology Data Exchange (ETDEWEB)

    Darula, Stanislav; Kocifaj, Miroslav; Kittler, Richard [ICA, Slovak Academy of Sciences, Bratislava (Slovakia); Kundracik, Frantisek [Department of Experimental Physics, FMPI, Comenius University, Bratislava (Slovakia)

    2010-12-15

    To ensure comfort and healthy conditions in interior spaces the thermal, acoustics and daylight factors of the environment have to be considered in the building design. Due to effective energy performance in buildings the new technology and applications also in daylight engineering are sought such as tubular light guides. These allow the transport of natural light into the building core reducing energy consumption. A lot of installations with various geometrical and optical properties can be applied in real buildings. The simplest set of tubular light guide consists of a transparent cupola, direct tube with high reflected inner surface and a ceiling cover or diffuser redistributing light into the interior. Such vertical tubular guide is often used on flat roofs. When the roof construction is inclined a bend in the light guide system has to be installed. In this case the cupola is set on the sloped roof which collects sunlight and skylight from the seen part of the sky hemisphere as well as that reflected from the ground and opposite facades. In comparison with the vertical tube some additional light losses and distortions of the propagated light have to be expected in bended tubular light guides. Recently the theoretical model of light propagation was already published and its applications are presented in this study solving illuminance distributions on the ceiling cover interface and further illuminance distribution on the working plane in the interior. (author)

  17. A web-based virtual lighting simulator

    Energy Technology Data Exchange (ETDEWEB)

    Papamichael, Konstantinos; Lai, Judy; Fuller, Daniel; Tariq, Tara

    2002-05-06

    This paper is about a web-based ''virtual lighting simulator,'' which is intended to allow architects and lighting designers to quickly assess the effect of key parameters on the daylighting and lighting performance in various space types. The virtual lighting simulator consists of a web-based interface that allows navigation through a large database of images and data, which were generated through parametric lighting simulations. At its current form, the virtual lighting simulator has two main modules, one for daylighting and one for electric lighting. The daylighting module includes images and data for a small office space, varying most key daylighting parameters, such as window size and orientation, glazing type, surface reflectance, sky conditions, time of the year, etc. The electric lighting module includes images and data for five space types (classroom, small office, large open office, warehouse and small retail), varying key lighting parameters, such as the electric lighting system, surface reflectance, dimming/switching, etc. The computed images include perspectives and plans and are displayed in various formats to support qualitative as well as quantitative assessment. The quantitative information is in the form of iso-contour lines superimposed on the images, as well as false color images and statistical information on work plane illuminance. The qualitative information includes images that are adjusted to account for the sensitivity and adaptation of the human eye. The paper also includes a section on the major technical issues and their resolution.

  18. Determination of ultra trace contaminants on silicon wafer surfaces using total-reflection X-ray fluorescence TXRF 'state-of-the-art'

    Science.gov (United States)

    Pahlke, S.; Fabry, L.; Kotz, L.; Mantler, C.; Ehmann, T.

    2001-11-01

    In a well balanced system of highly motivated, well trained personnel and automated equipment, pure reagents and bulk media, cleanrooms and integrated data management, total-reflection X-ray fluorescence (TXRF) can and must contribute to quality assurance and process stability, support and canalize creative engineering by continuous learning about materials and processes. TXRF has the advantage of controlled one-point calibration, a linear dynamic range of three orders of magnitude, high grade of automation in operation and data management, high up-time, and a simple control of data plausibility.

  19. Theoretical interpretations of enhanced laser light absorption

    International Nuclear Information System (INIS)

    Kruer, W.L.

    1975-01-01

    Intense laser light is not efficiently absorbed classically but can be absorbed by its conversion to electron plasma waves near the critical density. The physical mechanisms for this conversion are discussed, and some simple estimates for heating by plasma waves are applied to some recent experiments. Several effects which strongly influence the absorption of high intensity light are emphasized, including a nonlinear steepening of the plasma density profile which is demonstrated in computer simulations. Finally the possibility of an induced reflection of laser light due to instabilities in the underdense plasma before the critical density is also discussed. Such stimulated reflection can be particularly important in plasmas with very long density gradients. (U.S.)

  20. Sequential, progressive, equal-power, reflective beam-splitter arrays

    Science.gov (United States)

    Manhart, Paul K.

    2017-11-01

    The equations to calculate equal-power reflectivity of a sequential series of beam splitters is presented. Non-sequential optical design examples are offered for uniform illumination using diode lasers. Objects created using Boolean operators and Swept Surfaces can create objects capable of reflecting light into predefined elevation and azimuth angles. Analysis of the illumination patterns for the array are also presented.

  1. Quantifying the Assembly of Multicomponent Molecular Machines by Single-Molecule Total Internal Reflection Fluorescence Microscopy.

    Science.gov (United States)

    Boehm, E M; Subramanyam, S; Ghoneim, M; Washington, M Todd; Spies, M

    2016-01-01

    Large, dynamic macromolecular complexes play essential roles in many cellular processes. Knowing how the components of these complexes associate with one another and undergo structural rearrangements is critical to understanding how they function. Single-molecule total internal reflection fluorescence (TIRF) microscopy is a powerful approach for addressing these fundamental issues. In this article, we first discuss single-molecule TIRF microscopes and strategies to immobilize and fluorescently label macromolecules. We then review the use of single-molecule TIRF microscopy to study the formation of binary macromolecular complexes using one-color imaging and inhibitors. We conclude with a discussion of the use of TIRF microscopy to examine the formation of higher-order (i.e., ternary) complexes using multicolor setups. The focus throughout this article is on experimental design, controls, data acquisition, and data analysis. We hope that single-molecule TIRF microscopy, which has largely been the province of specialists, will soon become as common in the tool box of biophysicists and biochemists as structural approaches have become today. © 2016 Elsevier Inc. All rights reserved.

  2. Tailored plasmon-induced transparency in attenuated total reflection response in a metal-insulator-metal structure.

    Science.gov (United States)

    Matsunaga, Kouki; Hirai, Yusuke; Neo, Yoichiro; Matsumoto, Takahiro; Tomita, Makoto

    2017-12-19

    We demonstrated tailored plasmon-induced transparency (PIT) in a metal (Au)-insulator (SiO 2 )-metal (Ag) (MIM) structure, where the Fano interference between the MIM waveguide mode and the surface plasmon polariton (SPP) resonance mode induced a transparency window in an otherwise opaque wavenumber (k) region. A series of structures with different thicknesses of the Ag layer were prepared and the attenuated total reflection (ATR) response was examined. The height and width of the transparency window, as well as the relevant k-domain dispersion, were controlled by adjusting the Ag layer thickness. To confirm the dependency of PIT on Ag layer thickness, we performed numerical calculations to determine the electric field amplitude inside the layers. The steep k-domain dispersion in the transparency window is capable of creating a lateral beam shift known as the Goos-Hänchen shift, for optical device and sensor applications. We also discuss the Fano interference profiles in a ω - k two-dimensional domain on the basis of Akaike information criteria.

  3. Fundus reflectance : historical and present ideas

    NARCIS (Netherlands)

    Berendschot, T.T.J.M.; Delint, P.J.; Norren, D. van

    2003-01-01

    In 1851 Helmholtz introduced the ophthalmoscope. The instrument allowed the observation of light reflected at the fundus. The development of this device was one of the major advancements in ophthalmology. Yet ophthalmoscopy allows only qualitative observation of the eye. Since 1950 attempts were

  4. Astronomers Travel in Time and Space with Light

    Science.gov (United States)

    Mather, John C.

    2016-01-01

    This is an excerpt of John Mather's in a book titled: INSPIRED BY LIGHT, Reflections from the International Year of Light 2015. It was produced in January 2016 by SPIE, the European Physical Society (EPS), and The Abdus Salam International Centre for Theoretical Physics (ICTP) to commemorate the International Year of Light and Light-based Technologies 2015. The excerpt discusses how astronomers use light.

  5. Peculiarities of light transformation by the plate-lane biisotropic layer

    International Nuclear Information System (INIS)

    Dovydenko, S.N.

    2011-01-01

    In this article the peculiarities of transformation of light wave with arbitrary polarization by a half-infinity biisotropic medium and a biisotropic layer surrounded by different media are considered. Analytical expressions are obtained for refraction and reflection coefficients of transformed waves. The influence of layer parameters on refraction and reflection is investigated. It is shown that at arbitrary polarization of incident light the reflected wave is elliptically polarized. The possibility is established and the conditions are determined for π/2 turning the polarization plate of the wave at reflection from the biisotropic medium/layer. The refraction of the light wave by a plate-lake biisotropic layer is analyzed. It is grounded that the wave, transmitted the layer, is elliptically polarized, at that its ellipticity depends on chiral and non-reciprocal parameters, the non-reciprocality influence is weaker. (authors)

  6. Potential Sources of Polarized Light from a Plant Canopy

    Science.gov (United States)

    Vanderbilt, Vern; Daughtry, Craig; Dahlgren, Robert

    2016-01-01

    Field measurements have demonstrated that sunlight polarized during a first surface reflection by shiny leaves dominates the optical polarization of the light reflected by shiny-leafed plant canopies having approximately spherical leaf angle probability density functions ("Leaf Angle Distributions" - LAD). Yet for other canopies - specifically those without shiny leaves and/or spherical LADs - potential sources of optically polarized light may not always be obvious. Here we identify possible sources of polarized light within those other canopies and speculate on the ecologically important information polarization measurements of those sources might contain.

  7. Correlations between colonization of onion thrips and leaf reflectance measures across six cabbage varieties.

    Directory of Open Access Journals (Sweden)

    János Bálint

    Full Text Available The main purpose of this study was to reveal if the UV-A, and visible light reflection of leaves of white cabbage varieties is correlated to resistance against onion thrips. The antixenotic resistance (AR against onion thrips and thrips damage differed between varieties Balashi, Bloktor, Riana - considered resistant - and Green Gem, Hurricane, Quisor - considered susceptible. The solar UV-A (340-400 nm and visible (401-650 nm light reflection of white cabbage leaves were recorded. Correlation between AR against onion thrips and reflection of leaves in UV-A and visible range of the studied white cabbage varieties were computed. According to the AR evaluation onion thrips density was always higher on susceptible than on resistant varieties. The UV-A light reflection of head forming leaves and the contrast between head and exterior leaves (H/E was negatively correlated with onion thrips host preference at an early stage of cabbage head formation. The visible light reflection of both head forming and exterior leaves was also negatively correlated with onion thrips host preference. Susceptible varieties had greater damage ratings at harvest than resistant ones and positive correlations were observed between AR and damage. AR against onion thrips may be affected by differences in reflection of cabbage leaves at an early growth stage. It is suggested that more intensive reflection of leaves and/or higher contrast values between the reflectance intensity of head versus outer leaves made the resistant varieties less attractive to onion thrips. Our results reported here provide the first evidence of negative correlation between UV-A and visible reflection of leaves and AR of white cabbage against a dangerous insect pest, opening new perspectives for understanding the role of reflection by plant leaves in pest management.

  8. Design of a bolometer for total-energy measurement of the linear coherent light source pulsed X-ray laser

    International Nuclear Information System (INIS)

    Friedrich, S.; Li, L.; Ott, L.L.; Kolgani, Rajeswari M.; Yong, G.J.; Ali, Z.A.; Drury, O.B.; Ables, E.; Bionta, R.M.

    2006-01-01

    We are developing a cryogenic bolometer to measure the total energy of the linear coherent light source (LCLS) free electron X-ray laser to be built at the Stanford Linear Accelerator Center. The laser will produce ultrabright X-ray pulses in the energy range between 0.8 and 8 keV with ∼10 12 photons per ∼200 fs pulse at a repeat interval of 8 ms, and will be accompanied by a halo of spontaneous undulator radiation. The bolometer is designed to determine the total energy of each laser pulse to within (1- x ) Sr x MnO 3 sensor array at the metal-insulator transition, where the composition x is adjusted to produce the desired transition temperature. We discuss design considerations and material choices, and present numerical simulations of the thermal response

  9. Effect of Different Light Intensities on Total Phenolics and Flavonoids Synthesis and Anti-oxidant Activities in Young Ginger Varieties (Zingiber officinale Roscoe)

    Science.gov (United States)

    Ghasemzadeh, Ali; Jaafar, Hawa Z. E.; Rahmat, Asmah; Wahab, Puteri Edaroyati Megat; Halim, Mohd Ridzwan Abd

    2010-01-01

    Nowadays, phytochemicals and antioxidants in plants are raising interest in consumers for their roles in the maintenance of human health. Phenolics and flavonoids are known for their health-promoting properties due to protective effects against cardiovascular disease, cancers and other disease. Ginger (Zingiber officinale) is one of the traditional folk medicinal plants and it is widely used in cooking in Malaysia. In this study, four levels of glasshouse light intensities (310, 460, 630 and 790 μmol m−2s−1) were used in order to consider the effect of light intensity on the production, accumulation and partitioning of total phenolics (TP), total flavonoids (TF) and antioxidant activities in two varieties of Malaysian young ginger (Zingiber officinale). TF biosynthesis was highest in the Halia Bara variety under 310 μmol m−2s−1 and TP was high in this variety under a light intensity of 790 μmol m−2s−1. The highest amount of these components accumulated in the leaves and after that in the rhizomes. Also, antioxidant activities determined by the 1,1-Diphenyl-2-picryl-hydrazyl (DPPH) assay in both of varieties, increased significantly (p ≤ 0.01) with increasing TF concentration, and high antioxidant activity was observed in the leaves of Halia Bara grown under 310 μmol m−2s−1. The ferric reducing (FRAP) activity of the rhizomes was higher than that of the leaves in 310 μmol m−2s−1 of sun light. This study indicates the ability of different light intensities to enhance the medicinal components and antioxidant activities of the leaves and young rhizomes of Zingiber officinale varieties. Additionally, this study also validated their medicinal potential based on TF and TP contents. PMID:21152306

  10. Effect of Different Light Intensities on Total Phenolics and Flavonoids Synthesis and Anti-oxidant Activities in Young Ginger Varieties (Zingiber officinale Roscoe

    Directory of Open Access Journals (Sweden)

    Ali Ghasemzadeh

    2010-10-01

    Full Text Available Nowadays, phytochemicals and antioxidants in plants are raising interest in consumers for their roles in the maintenance of human health. Phenolics and flavonoids are known for their health-promoting properties due to protective effects against cardiovascular disease, cancers and other disease. Ginger (Zingiber officinale is one of the traditional folk medicinal plants and it is widely used in cooking in Malaysia. In this study, four levels of glasshouse light intensities (310, 460, 630 and 790 μmol m−2s−1 were used in order to consider the effect of light intensity on the production, accumulation and partitioning of total phenolics (TP, total flavonoids (TF and antioxidant activities in two varieties of Malaysian young ginger (Zingiber officinale. TF biosynthesis was highest in the Halia Bara variety under 310 μmol m−2s−1 and TP was high in this variety under a light intensity of 790 μmol m−2s−1. The highest amount of these components accumulated in the leaves and after that in the rhizomes. Also, antioxidant activities determined by the 1,1-Diphenyl-2-picryl-hydrazyl (DPPH assay in both of varieties, increased significantly (p ≤ 0.01 with increasing TF concentration, and high antioxidant activity was observed in the leaves of Halia Bara grown under 310 μmol m−2s−1. The ferric reducing (FRAP activity of the rhizomes was higher than that of the leaves in 310 μmol m−2s−1 of sun light. This study indicates the ability of different light intensities to enhance the medicinal components and antioxidant activities of the leaves and young rhizomes of Zingiber officinale varieties. Additionally, this study also validated their medicinal potential based on TF and TP contents.

  11. A reflectivity profilometer for the optical characterisation of graded reflectivity mirrors in the 250 nm - 1100 nm spectral region

    International Nuclear Information System (INIS)

    Colucci, Alessandro; Nichelatti, Enrico

    1998-04-01

    It's developed the prototype of an instrument that can be used for the optical characterisation of graded reflectivity mirrors at any wavelength in the spectral region from 250 nm to 1100 nm. The instrument utilises a high-pressure Xe arc lamp as light source. Light is spectrally filtered by means of a grating monochromator. The sample is illuminated with an image of the monochromator exit slit. After reflection from the sample, this image is projected onto a 1024-elements charge-coupled device linear array driven by a digital frame board and interfaced with a personal computer. It's tested the instrument accuracy by comparing measurement results with the corresponding ones obtained by means of a laser scanning technique. Measurement Rms repeatability has been estimated to be approximately of 0.8% [it

  12. Closed Paths of Light Trapped in a Closed Fermat Curve

    Science.gov (United States)

    Dana-Picard, Thierry; Naiman, Aaron

    2002-01-01

    Geometric constructions have previously been shown that can be interpreted as rays of light trapped either in polygons or in conics, by successive reflections. The same question, trapping light in closed Fermat curves, is addressed here. Numerical methods are used to study the behaviour of the reflection points of a triangle when the degree of the…

  13. Confocal total reflection X-ray fluorescence technology based on an elliptical monocapillary and a parallel polycapillary X-ray optics.

    Science.gov (United States)

    Zhu, Yu; Wang, Yabing; Sun, Tianxi; Sun, Xuepeng; Zhang, Xiaoyun; Liu, Zhiguo; Li, Yufei; Zhang, Fengshou

    2018-07-01

    A total reflection X-ray fluorescence (TXRF) spectrometer based on an elliptical monocapillary X-ray lens (MXRL) and a parallel polycapillary X-ray lens (PPXRL) was designed. This TXRF instrument has micro focal spot, low divergence and high intensity of incident X-ray beam. The diameter of the focal spot of MXRL was 16.5 µm, and the divergence of the incident X-ray beam was 3.4 mrad. We applied this TXRF instrument to the micro analysis of a single-layer film containing Ni deposited on a Si substrate by metal vapor vacuum arc ion source. Copyright © 2018 Elsevier Ltd. All rights reserved.

  14. Excitation of anodized alumina films with a light source

    DEFF Research Database (Denmark)

    Aggerbeck, Martin; Canulescu, Stela; Rechendorff, K.

    Optical properties of anodized aluminium alloys were determined by optical diffuse reflectance spectroscopy of such films. Samples with different concentrations of dopants were excited with a white-light source combined with an integrating sphere for fast determination of diffuse reflectance....... The UV-VIS reflectance of Ti-doped anodized aluminium films was measured over the wavelength range of 200 nm to 900 nm. Titanium doped-anodized aluminium films with 5-15 wt% Ti were characterized. Changes in the diffuse light scattering of doped anodized aluminium films, and thus optical appearance......, with doping are discussed. Using the Kubelka-Munk model on the diffuse reflectance spectra of such films, the bandgap Eg of the oxide alloys can be determined....

  15. The Reflection Effect on the Eclipsing Binary by the Wilson and Devinney's Model and Russell and Merrill's Model

    Directory of Open Access Journals (Sweden)

    Seong Hee Choea

    1992-06-01

    Full Text Available The reflection effect on three types of eclipsing binaries has been analyzed Wilson and Devinney's model and Russell and Merrill's model. The reflection effect was displayed on the theoretical light curves for the various conditions using the Wilson and Devinney's light curve program. Two models were compared after the rectifing the theoretical light curves including the reflection effect with the Russell and Merrill's method. The result shows that two models have an agreement on the reflection effect just in cases of the small difference in temperature and albedo between two stars in the system.

  16. Studies of dust grain properties in infrared reflection nebulae.

    Science.gov (United States)

    Pendleton, Y J; Tielens, A G; Werner, M W

    1990-01-20

    We have developed a model for reflection nebulae around luminous infrared sources embedded in dense dust clouds. The aim of this study is to determine the sizes of the scattering grains. In our analysis, we have adopted an MRN-like power-law size distribution (Mathis, Rumpl, and Nordsieck) of graphite and silicate grains, but other current dust models would give results which were substantially the same. In the optically thin limit, the intensity of the scattered light is proportional to the dust column density, while in the optically thick limit, it reflects the grain albedo. The results show that the shape of the infrared spectrum is the result of a combination of the scattering properties of the dust, the spectrum of the illuminating source, and foreground extinction, while geometry plays a minor role. Comparison of our model results with infrared observations of the reflection nebula surrounding OMC-2/IRS 1 shows that either a grain size distribution like that found in the diffuse interstellar medium, or one consisting of larger grains, can explain the observed shape of the spectrum. However, the absolute intensity level of the scattered light, as well as the observed polarization, requires large grains (approximately 5000 angstroms). By adding water ice mantles to the silicate and graphite cores, we have modeled the 3.08 micrometers ice band feature, which has been observed in the spectra of several infrared reflection nebulae. We show that this ice band arises naturally in optically thick reflection nebulae containing ice-coated grains. We show that the shape of the ice band is diagnostic of the presence of large grains, as previously suggested by Knacke and McCorkle. Comparison with observations of the BN/KL reflection nebula in the OMC-1 cloud shows that large ice grains (approximately 5000 angstroms) contribute substantially to the scattered light.

  17. Light-stimulated accumulation of transcripts of nuclear and chloroplast genes for ribulosebisphosphate carboxylase

    Energy Technology Data Exchange (ETDEWEB)

    Smith, S M; Ellis, R J

    1981-01-01

    The chloroplast enzyme, ribulosebisphosphate carboxylase, consists of large subunit polypeptides encoded in the chloroplast genome and small subunit polypeptides encoded in the nuclear genome. Cloned DNA complementary to the small subunit mRNA hybridizes to a single RNA species of 900-1000 nucleotides in both total and poly(A)-containing RNA from leaves of Pisum sativum, but does not hybridize to chloroplast RNA. Small subunit cDNA hybridizes to at least three RNA species from nuclei, two of which are of higher molecular weight than the mature mRNA. A cloned large subunit DNA sequence hybridizes to a single species of Pisum chloroplast RNA containing approximately 1700 nucleotides, but does not hybridize to nuclear RNA. The light-stimulation of carboxylase accumulation reflects increases in the amounts of transcripts for both subunits in total leaf RNA. Transcripts of the small subunit gene are more abundant in nuclear RNA from light-grown leaves than in that from dark-grown leaves. These results suggest that the stimulation of carboxylase accumulation by light is mediated at the level of either transcription or RNA turnover in both nucleus and chloroplast.

  18. Tailoring broadband light trapping of GaAs and Si substrates by self-organised nanopatterning

    Energy Technology Data Exchange (ETDEWEB)

    Martella, C.; Chiappe, D.; Mennucci, C.; Buatier de Mongeot, F. [Dipartimento di Fisica, Università di Genova, via Dodecaneso 33, I-16146 Genova (Italy)

    2014-05-21

    We report on the formation of high aspect ratio anisotropic nanopatterns on crystalline GaAs (100) and Si (100) substrates exploiting defocused Ion Beam Sputtering assisted by a sacrificial self-organised Au stencil mask. The tailored optical properties of the substrates are characterised in terms of total reflectivity and haze by means of integrating sphere measurements as a function of the morphological modification at increasing ion fluence. Refractive index grading from sub-wavelength surface features induces polarisation dependent anti-reflection behaviour in the visible-near infrared (VIS-NIR) range, while light scattering at off-specular angles from larger structures leads to very high values of the haze functions in reflection. The results, obtained for an important class of technologically relevant materials, are appealing in view of photovoltaic and photonic applications aiming at photon harvesting in ultrathin crystalline solar cells.

  19. A sensitive method for determining total vanadium in water samples using colorimetric-solid-phase extraction-fiber optic reflectance spectroscopy

    International Nuclear Information System (INIS)

    Filik, Hayati; Yanaz, Zeynep

    2009-01-01

    A selective colorimetric-solid-phase extraction (C-SPE) method for the determination of total vanadium in water samples was developed. This method introduced a new variation of C-SPE. The colour reaction is based on the reaction of vanadium(V) ternary complex formed with 1-(2-Pyridylazo)-2-naphtol (PAN) in the presence hydrogen peroxide (H 2 O 2 ). In this technique, the target analytes in samples are extracted onto solid matrix loaded with a colorimetric reagent and then quantified directly on the adsorbent surface by using a miniature fiber optic reflectance spectrometer. The measurements were carried out at a wavelength of 589.4 nm since it yielded the largest divergence different in reflectance spectra before and after reaction with the vanadium. The overall time required for the C-SPE procedure was ∼20 min. The amount of concentrated V is then determined in a few seconds by using miniature reflectance spectrometer. At the optimal conditions, a calibration curve was constructed, revealing a linear range of 0.05-0.52 mg L -1 and a detection limit as low as 0.01 mg L -1 while the RSD lower than 2.8%. In order to verify the accuracy of the method, a certified reference water samples (TMDA) were analysed and the results obtained were in good agreement with the certified values. The proposed method was applied to the determination of vanadium in tap water, seawater samples with a recovery for the spiked samples in the range of 98-102%.

  20. Enhancing Light-Trapping Properties of Amorphous Si Thin-Film Solar Cells Containing High-Reflective Silver Conductors Fabricated Using a Nonvacuum Process

    Directory of Open Access Journals (Sweden)

    Jun-Chin Liu

    2014-01-01

    Full Text Available We proposed a low-cost and highly reflective liquid organic sheet silver conductor using back contact reflectors in amorphous silicon (a-Si single junction superstrate configuration thin-film solar cells produced using a nonvacuum screen printing process. A comparison of silver conductor samples with vacuum-system-sputtered silver samples indicated that the short-circuit current density (Jsc of sheet silver conductor cells was higher than 1.25 mA/cm2. Using external quantum efficiency measurements, the sheet silver conductor using back contact reflectors in cells was observed to effectively enhance the light-trapping ability in a long wavelength region (between 600 nm and 800 nm. Consequently, we achieved an optimal initial active area efficiency and module conversion efficiency of 9.02% and 6.55%, respectively, for the a-Si solar cells. The results indicated that the highly reflective sheet silver conductor back contact reflector layer prepared using a nonvacuum process is a suitable candidate for high-performance a-Si thin-film solar cells.