WorldWideScience

Sample records for total psa levels

  1. Comparative evaluation of PSA-Density, percent free PSA and total PSA

    OpenAIRE

    Ströbel, Greta

    2010-01-01

    BACKGROUND The objective of this study was to evaluate the prostate specific antigen (PSA) density (PSAD) (the quotient of PSA and prostate volume) compared with the percent free PSA (%fPSA) and total PSA (tPSA) in different total PSA (tPSA) ranges from 2 ng/mL to 20 ng/mL. Possible cut-off levels depending on the tPSA should be established. METHODS In total, 1809 men with no pretreatment of the prostate were enrolled between 1996 and 2004. Total and free PSA were measured with t...

  2. Seismic Level 2 PSA

    International Nuclear Information System (INIS)

    Dirksen, Gerben; Pellissetti, Manuel; Duncan-Whiteman, Paul

    2014-01-01

    For most external events, the calculation of the core damage frequency (CDF) in Level 1 PSA is sufficient to be able to show that the contribution of the event to the plant risk is negligible. However, it is not sufficient to compare the CDF due to the external event to the total plant CDF; instead the Level 1 PSA result for the event should be compared to the large early release frequency (LERF), or alternatively arguments should be given why the CDF from the external event will not contribute mostly to LERF. For seismic events in particular, it can often not be easily excluded that sequences leading to core damage would not also result in LERF. Since the confinement function is one of the most essential functions for Level 2 PSA, special care must be taken of the containment penetrations. For example systems with containment penetrations that are normally closed during operation or are designed to withstand more than the maximum containment pressure are normally screened out in the Level 2 PSA for the containment isolation function, however the possibility of LOCA in such systems due to an earthquake may nevertheless lead to containment bypass. Additionally, the functionality of passive features may be compromised in case of a beyond design earthquake. In the present paper, we present crucial ingredients of a methodology for a Level 2 seismic PSA. This methodology consists of the following steps: Extension of the seismic equipment list (SEL) to include Level 2 PSA relevant systems (e.g. containment isolation system, features for core melt stabilization, hydrogen mitigation systems), Determination of the systems within the existing SEL with increased demands in case of severe accidents, Determination of essential components for which a dedicated fragility analysis needs to be performed. (author)

  3. Low percentage of free prostate-specific antigen (PSA) is a strong predictor of later detection of prostate cancer among Japanese men with serum levels of total PSA of 4.0 ng/mL or less.

    Science.gov (United States)

    Sasaki, Mitsuharu; Ishidoya, Shigeto; Ito, Akihiro; Saito, Hideo; Yamada, Shigeyuki; Mitsuzuka, Koji; Kaiho, Yasuhiro; Shibuya, Daisuke; Yamaguchi, Takuhiro; Arai, Yoichi

    2014-11-01

    To investigate the effect of the percentage of free prostate-specific antigen (%fPSA) on future prostate cancer risk. We examined serum total PSA (tPSA) and %fPSA annually in a prostate cancer-screening cohort between July 2001 and June 2011. Men with tPSA >4.0 ng/mL or tPSA of 2.0-4.0 ng/mL with %fPSA ≤12% were screened as positive and were recommended to undergo a biopsy. The study population consisted of 6368 men, aged 40-79 years, who had tPSA ≤4.0 ng/mL at initial screening and who subsequently underwent 1 or more screenings. We calculated the cumulative risk and hazard ratio of prostate cancer stratified by the initial %fPSA groups as quartiles of prostate cancer patients. During a median follow-up of 36 months, 119 men were diagnosed with prostate cancer. The lowest quartile of %fPSA (22.2%). For the subset with an initial tPSA ≤1.0 ng/mL, all men diagnosed with cancer had an initial %fPSA ≤33.3% (median). For the subset with tPSA >1.0 ng/mL, men with %fPSA ≤23.0% (median) had significantly higher risk for cancer than those with %fPSA >23.0% (P men with prostate cancer in whom pathologic findings were available, 79 (69.3%) had a Gleason score ≥3 + 4 = 7. A low %fPSA is a strong predictor of a subsequent diagnosis of prostate cancer among men with tPSA levels ≤4.0 ng/mL. Measurement of %fPSA might enhance the detection of high-grade cancer that warrants aggressive treatment. Copyright © 2014 Elsevier Inc. All rights reserved.

  4. Guideline level-3 PSA

    International Nuclear Information System (INIS)

    Roelofsen, P.M.; Van der Steen, J.

    1993-09-01

    For several applications of radioactive materials calculations must be executed to determine the radiation risk for the population. A guideline for the risk calculation method of two main sources: nuclear power plants, and other intended and unintended activities with radioactive materials, is given. The standards, recommendations and regulations in this report concern mainly the analysis of the radiological (external) consequences of nuclear power plant accidents, classified as level-3 PSA (Probabilistic Safety Analysis). Level-3 PSA falls within the scales 5-7 of the International Nuclear Event Scale (INES). The standards, etc., focus on the risks for groups of people and the so-called maximum individual risk. In chapter two the standards and regulations are formulated for each part of level-3 PSA: the source term spectrum, atmospheric distribution and deposition, exposure to radiation doses and calculation of radiation doses, dose-response relationships, measures to reduce the effect of radiation doses, design basis accidents, and finally uncertainty analysis. In chapter four, modelled descriptions are given of the standards and regulations, which could or should be used in a calculation program in case of level-3 PSA. In chapter three the practical execution of a probabilistic consequences analysis, the collection of input data and the presentation of the results are dealt with. 2 figs., 14 tabs., 64 refs

  5. Detection of prostate cancer with complexed PSA and complexed/total PSA ratio - is there any advantage?

    OpenAIRE

    Strittmatter, F; Stieber, P; Nagel, D; Füllhase, C; Walther, S; Stief, CG; Waidelich, R

    2011-01-01

    Abstract Objective To evaluate the performance of total PSA (tPSA), the free/total PSA ratio (f/tPSA), complexed PSA (cPSA) and the complexed/total PSA ratio (c/tPSA) in prostate cancer detection. Methods Frozen sera of 442 patients have been analysed for tPSA, free PSA (fPSA) and cPSA. 131 patients had prostate cancer and 311 patients benign prostatic hyperplasia. Results Differences in the distribution of the biomarkers were seen as follows: tPSA, cPSA and c/tPSA were significantly higher i...

  6. Opium consumption is negatively associated with serum prostate-specific antigen (PSA), free PSA, and percentage of free PSA levels.

    Science.gov (United States)

    Safarinejad, Mohammad Reza; Asgari, Seyyed Alaeddin; Farshi, Alireza; Iravani, Shahrokh; Khoshdel, Alireza; Shekarchi, Babak

    2013-01-01

    Addiction to opium continues to be a major worldwide medical and social problem. The study addressing the association between opium consumption and serum prostate-specific antigen (PSA) level is lacking. We determined the effects of opium consumption on serum PSA levels in opium-addict men. Our study subjects comprised 438 opium-addict men with a mean age of 52.2 ± 6.4 years (group 1). We compared these men with 446 men who did not indicate current or past opium use (group 2). Serum total PSA (tPSA), free PSA (fPSA), % fPSA, and sex hormones were compared between the 2 groups. The mean serum tPSA level was significantly lower in group 1 (1.05 ng/mL) than in controls (1.45 ng/mL) (P = 0.001). Opium consumption was also associated with lower fPSA (P = 0.001) and % fPSA (P = 0.001). Serum free testosterone level in opium-addict patients (132.5 ± 42 pg/mL) was significantly lower than that in controls (156.2 ± 43 pg/mL) (P = 0.03). However, no significant correlation existed between tPSA and free testosterone levels (r = 0.28, 95% CI, -0.036 to 0.51, P = 0.34). Among the patients with cancer in group 1, 35% were found to have high-grade tumor (Gleason score ≥ 7) compared with 26.7% in group 2 (P = 0.02). Total PSA and fPSA were strongly correlated with duration of opium use (r = -0.06, 95% CI, -0.04 to -0.08, P = 0.0001; and r = -0.05, 95% CI, -0.03 to -0.07, P = 0.0001, respectively). Opium consumption is independently and negatively associated with serum tPSA, fPSA, and % fPSA levels.

  7. Development of kits for total PSA monitoring

    International Nuclear Information System (INIS)

    Suprarop, P.

    1999-01-01

    The development of kits for Total PSA assay has shown promising results. All essential components of the assay were prepared with reproducibility and used to optimize the assay. By choosing two steps method, we could avoid the hook effect and obtain satisfactory Q.C. parameters of the standard curve i.e. blank = 0.8%, maximum binding = 65%. If reference material for calibration of the standard is agree upon, the validation could then be carried out with total confidence. Our final goal is to reduce the step of incubation to just one step with no interference from hook effect

  8. Serum PSA levels in the Indian population: Is it different?

    Science.gov (United States)

    Agrawal, Amit; Karan, Shailesh Chandra

    2017-04-01

    Serum prostate-specific antigen (PSA) is an important tumour, marker which is widely used to trigger trans-rectal ultrasound (TRUS)-guided prostate biopsy. However, the PSA levels vary with race and ethnicity. Therefore, there is a need to have an Indian reference range. All adult male patients meeting the inclusion and exclusion criteria were enrolled in this study. They were subjected to assessment of serum total PSA, digital rectal examination and trans-abdominal ultrasound. If any one or more of these were found abnormal, then a TRUS-guided 12-core prostate biopsy was done. Patients who were detected to have prostatic cancer were excluded from the final analysis. The data so obtained was grouped among the following three age groups: 40-49, 50-59 and 60-70 years, and the age-specific PSA values, prostatic volume and PSA density were found. A total of 1772 patients were analysed. The mean serum total PSA was 1.76 ng/ml with a standard deviation of 2.566 ng/ml. Group-wise age distribution of the mean serum total PSA was 1.22, 1.97 and 2.08 ng/ml in 40-49, 50-59 and 60-70 years age groups. The mean total PSA and the age-specific PSA range tend to be lower in the Indians than the Western population.

  9. PSA Level 2:Scope And Method Of PSA Level 2 For Nuclear Power Plant

    International Nuclear Information System (INIS)

    Widodo, Surip; Antariksawan, Anhar R.

    2001-01-01

    A study of scope and method of PSA Level 2 had been conducted. The background of the study is the need to gain the capability to well perform PSA Level 2 for nuclear facilities. This study is a literature survey. The scope of PSA Level 2 consists of generating plant damage states, accident progression analysis, and grouping source terms. Concerning accident progression analysis, several methods are used, among others event tree method, named accident progression event tree (APET) or containment event tree (CET), and fault tree method. The end result of PSA Level 2 is release end states which is grouped into release bins. The results will be used for PSA Level 3

  10. Review of APR+ Level 2 PSA

    International Nuclear Information System (INIS)

    Lehner, J.R.; Mubayi, V.; Pratt, W.T.

    2012-01-01

    Brookhaven National Laboratory (BNL) assisted the Korea Institute of Nuclear Safety (KINS) in reviewing the Level 2 Probabilistic Safety Assessment (PSA) of the APR+ Advanced Pressurized Water Reactor (PWR) prepared by the Korea Hydro and Nuclear Power Co., Ltd (KHNP) and KEPCO Engineering and Construction Co., Inc. (KEPCO-E and C). The work described in this report involves a review of the APR+ Level 2 PSA submittal (Ref. 1). The PSA and, therefore, the review is limited to consideration of accidents initiated by internal events. As part of the review process, the review team also developed three sets of Requests for Additional Information (RAIs). These RAIs were provided to KHNP and KEPCO-E and C for their evaluation and response. This final detailed report documents the review findings for each technical element of the PSA and includes consideration of all of the RAIs made by the reviewers as well as the associated responses. This final report was preceded by an interim report (Ref. 2) that focused on identifying important issues regarding the PSA. In addition, a final meeting on the project was held at BNL on November 21-22, 2011, where BNL and KINS reviewers discussed their preliminary review findings with KHNP and KEPCO-E and C staffs. Additional information obtained during this final meeting was also used to inform the review findings of this final report. The review focused not only on the robustness of the APR+ design to withstand severe accidents, but also on the capability and acceptability of the Level 2 PSA in terms of level of detail and completeness. The Korean nuclear regulatory authorities will decide whether the PSA is acceptable and the BNL review team is providing its comments for KINS consideration. Section 2.0 provides the basis for the BNL review. Section 3.0 presents the review of each technical element of the PSA. Conclusions and a summary are presented in Section 4.0. Section 5.0 contains the references.

  11. Evaluation of total PSA assay on vitros ECi and correlation with Kryptor-PSA assay.

    Science.gov (United States)

    Cassinat, B; Wacquet, M; Toubert, M E; Rain, J D; Schlageter, M H

    2001-01-01

    An increasing number of multiparametric immuno-analysers for PSA assays are available. As different immuno-assays may vary in their analytical quality and their accuracy for the follow-up of patients, expertise is necessary for each new assay. The PSA assay on the Vitros-ECi analyser has been evaluated and compared with the PSA assay from the Kryptor analyser. Variation coefficients were 0.91 to 1.98% for within-run assays, and 4.2% to 5.4% for interassay (PSA levels = 0.8 microgram/L to 33.6 micrograms/L). Dilution tests showed 93 to 136% recovery until 70 micrograms/L PSA. Functional sensitivity was estimated at 0.03 microgram/L. Equimolarity of the test was confirmed. Correlation of PSA levels measured with Vitros-ECi and Kryptor analysers displayed a correlation coefficient r2 of 0.9716. The half-lives and doubling times of PSA were similar using both methods. Vitros-ECi PSA assay meets the major criteria for the management of prostate cancer patients.

  12. Impact of total PSA, PSA doubling time and PSA velocity on detection rates of 11C-Choline positron emission tomography in recurrent prostate cancer

    NARCIS (Netherlands)

    Rybalov, Maxim; Breeuwsma, Anthonius J.; Leliveld, Anna M.; Pruim, Jan; Dierckx, Rudi A.; de Jong, Igle J.

    PURPOSE: To evaluate the effect of total PSA (tPSA) and PSA kinetics on the detection rates of (11)C-Choline PET in patients with biochemical recurrence (BCR) after radical prostatectomy (RP) or external beam radiotherapy (EBRT). METHODS: We included 185 patients with BCR after RP (PSA >0.2 ng/ml)

  13. Incorporating Level-2 PSA Feature of CONPAS into AIMS-PSA Software

    International Nuclear Information System (INIS)

    Han, Sang Hoon; Lim, Hogon; Ahn, Kwang Il

    2014-01-01

    CONPAS (CONtainment Performance Analysis System) utilizes a methodology to treat containment phenomena in detail like APET but in simple way. In mid 2000's, KAERI has developed very fast cut set generator FTREX and PC's OS (Operating system) has changed into Windows 95. Thus, KAERI has developed new Level-1 PSA software, called AIMS-PSA (Advanced Information Management System for PSA) to replace KIRAP. Recently, KAERI has been developing an integrated PSA platform, called OCEANS (On-line Consolidator and Evaluator of All mode risk for Nuclear System), for the risk assessment of all power modes and all hazards. CONPAS for Level-2 PSA was developed in 1990's using the Visual Basic 6.0 compiler which is not supported any more. It needs to be updated for the integrated PSA software framework. This paper describes a study to incorporate the features of CONPAS into AIMS-PSA. The basic idea is to follow the approach of CONPAS, but in the integrated way. Various approaches for Level-2 PSA have been used since WASH-1400. APET approach of NUREG-1150 study would be most comprehensive and complex methodology for containment event tree analysis. CONPAS is the Level-2 PSA software to utilize an approach to treat containment phenomena in detail like APET but in simple way. But, new Level-2 PSA software is required to develop more integrated PSA framework. A modified approach of CONPAS is developed and incorporated in AIMS-PSA software that can handle Level-1 and Level-2 PSA in the integrated way (from the viewpoint of event tree and fault tree). AIMS-PSA combines whole Level-2 PSA model to produce a One Top fault tree and to generate cut sets in the same way as Level-1 PSA. Quantification results of Level-2 PSA such as frequency for each STC can be calculated from the minimal cut sets

  14. Measurement of serum isoform [-2]proPSA derivatives shows superior accuracy to magnetic resonance imaging in the diagnosis of prostate cancer in patients with a total prostate-specific antigen level of 2-10 ng/ml.

    Science.gov (United States)

    Furuya, Kazuhiro; Kawahara, Takashi; Narahara, Masaki; Tokita, Takashi; Fukui, Sachi; Imano, Masashi; Mitome, Taku; Ito, Yusuke; Izumi, Koji; Osaka, Kimito; Yokomizo, Yumiko; Hayashi, Narihiko; Hasumi, Hisashi; Nawata, Shintaro; Kawano, Tsuyoshi; Yao, Masahiro; Uemura, Hiroji

    2017-08-01

    More accurate diagnostic procedures for prostate cancer are needed to avoid unnecessary biopsy due to the low specificity of prostate-specific antigen (PSA). Recent studies showed that the percentage of serum isoform [-2]proPSA (p2PSA) to free PSA (%p2PSA), the Prostate Health Index (PHI) and magnetic resonance imaging (MRI) were more accurate than PSA. The aim of this study was to test the accuracy of %p2PSA, PHI and MRI in discriminating patients with and without prostate cancer. The subjects were 50 consecutive men with a PSA level of 2.0-10.0 ng/ml, who underwent prostate biopsy from October 2012 to July 2014. These patients underwent multiparametric MRI before biopsy, and their serum samples were measured for PSA, free PSA and p2PSA. The sensitivity, specificity and accuracy of PHI, %p2PSA and MRI were compared with PSA in the diagnosis of biopsy-confirmed prostate cancer. In a univariate analysis, %p2PSA [area under the curve (AUC): 0.811] and PHI (AUC 0.795) were more accurate than MRI (AUC: 0.583) and PSA (AUC: 0.554) for prostate cancer detection. At 60% sensitivity, the specificity of PHI (76.5%) was higher than that of MRI (52.9%). For significant cancer detection, %p2PSA (AUC: 0.745), PHI (AUC: 0.791) and MRI (AUC: 0.739) were marginally more accurate than PSA (AUC: 0.696). At 85% sensitivity, the specificity of MRI (62.1%) was higher than that of PHI (34.5%). PHI and %p2PSA can be used for screening the general population and MRI can be used for detection of significant cancer in patients suspected, from screening tests, of having prostate cancer.

  15. ASAMPSA-E guidance for level 2 PSA Volume 2. Implementing external Events modelling in Level 2 PSA

    International Nuclear Information System (INIS)

    Cazzoli, E.; Vitazkova, J.; Loeffler, H.; Burgazzi, L.

    2016-01-01

    The objective of the present document is to provide guidance on the implementation of external events into an 'extended' L2 PSA. It has to be noted that L2 PSA addresses issues beginning with fuel degradation and ending with the release of radionuclides into the environment. Therefore, the present document may touch upon, but does not evaluate explicitly issues that involve events or phenomena which occur before the fuel begins to degrade. Following the accident at Fukushima Dai-ichi, the nuclear safety community has realized that much attention should be given to the areas of operator interventions and accidents that may develop at the same time in more than one unit if they are initiated by one or more common external events. For this reason and to fulfill the PSA end-users' wish list (as reflected by an ASAMPSA-E survey), the attention is mostly focused on interface between L1 and L2 PSA, fragility analysis, human response analysis and some consideration is given to L2 PSA modeling of severe accidents for multiple unit sites, even though it is premature to provide extensive guidance in this area. The following recommendations, mentioned in various sections within this document, are summarized here: 1. Vulnerability/fragility analyses should be performed with respect to all external hazards and all structures, systems and components potentially affected that could be relevant to L2 PSA, 2. Importance should be given to the assessment of human performance following extreme external events; for extreme circumstances with high stress level, low confidence is justified for SAM human interventions and for such conditions, human interventions could be analyzed as sensitivity cases only in L2 PSA, 3. Results presentation should include assessment of total risk measures compared with risk targets able to assess all contributions to the risk and to judge properly the safety, 4. Total risk measures shall be associated to appropriate information on all

  16. Regulatory requirements on PSA level 2: Review, aspects and applications

    International Nuclear Information System (INIS)

    Husarcek, J.

    2003-01-01

    The general requirements concerning utility obligations, probabilistic safety criteria (CDF should not exceed 1.0E-4/reactor year and LERF should not exceed 1.0E-5/reactor year), documentation and results, living PSA requirements and major steps in level 2 PSA are presented. PSA developments in Slovakia, collection and assembly of information, plant damage states, containment performance and failure modes, severe accident progression analyses, containment failure modes and source terms as a part of performed level 2 PSA are discussed. The PSA applications in design and operation evaluation, support to plant upgrade and modifications are also described. At the end, the following conclusion is made: more extensive PSA application needs to foster the exchange of experience and communication between PSA specialists, non-PSA engineers, designers, and the regulatory body staff responsible for safety assessment, inspection and enforcement

  17. Association of PSA, free-PSA and testosteron levels in serum of patients with benign prostate hyperplasia (BPH) and prostate cancer

    International Nuclear Information System (INIS)

    Wiwin Mailana; Kristina Dwi P; Sri Insani WW; Puji Widayati

    2015-01-01

    Prostate cancer screening can be done by measuring the concentration levels of PSA, free-PSA and testosterone in serum that examined with radioimmunoassay (RIA). A total of 30 patients of 45-81 years old had enrolled in this study and were taken their venous blood. The aim of research is to know the relationship between PSA and testosterone free-PSA with BPH and prostate cancer. Results showed that there was no correlation between age with BPH and prostate cancer (p = 0.06), but there is a relationship between PSA with BPH and prostate cancer (p = 0.002), the relationship between free-PSA with BPH and prostate cancer (p = 0.001). No correlation was found between PSA ratio with BPH and prostate cancer as well as the absence of a relationship between testosterone with BPH and prostate cancer (p = 0.924). (author)

  18. Clinical diagnostic value of combined determination of serum tPSA, cPSA and IGF-I levels in patients with prostatic disorders

    International Nuclear Information System (INIS)

    Zhang Bashan; Zhang Zigang; Lai Fudi

    2008-01-01

    Objective: To investigate the diagnostic value of combined determination of serum total prostatic specific antigen (tPSA), complex prostatic specific antigen (cPSA) and IGF-I levels in patients with prostatic disorders. Methods: Serum tPSA, cPSA (with CLIA) and IGF-I (with IRMA) levels were determined in 41 patients with prostatic carcinoma, 60 patients with benign prosta- tic hypertrophy (BPH) and 55 controls. Results: The serum tPSA, cPSA and IGF-I levels in patients with prostatic cancer were significantly higher than those in patients with BPH and controls (P<0.01). Taking the cut-off values of 4ng/ml, 3.6ng/ml and 150 for tPSA, cPSA and IGF-I respectively, the combined determination of these three items would yield a sensitivity of 88.6%, specificity of 84.9%, positive predicative value of 83% and negative predicative value of 90.0% for diagnosis of prostatic cancer. Conclusion: Combined determination of tPSA, cPSA and IGF-I would yield better sensitive and accurate diagnostic rate in patients with prostatic cancer, especially in those with laboratory values within the 'grey zone'. (authors)

  19. Lessons learned form IRSN review of Flamanville 3 Level PSA

    International Nuclear Information System (INIS)

    Georgescu, G.; Corenwinder, F.

    2012-01-01

    In the frame of the construction and licensing of Flamanville 3 NPP the PSA (Probabilistic Safety Assessment)plays an important role for the EPR Project assessment. The PSA was used for early design verification of EPR Reactor, several design improvement being defined based on these PSA insights and following the discussions with the French and German safety authorities. IRSN, as the French Safety Authority (ASN) technical support organization, performs the review of the PSA developed by the plant operator (EDF). The paper presents the main issues regarding the using of 'design PSA', identified by IRSN following the review of the internal events Level 1 PSA transmitted by EDF in the frame of the anticipated instruction of the application for operating license of the Flamanville 3 reactor. (authors)

  20. Level 2 PSA methodology and severe accident management

    International Nuclear Information System (INIS)

    1997-01-01

    The objective of the work was to review current Level 2-PSA (Probabilistic Safety Assessment) methodologies and practices and to investigate how Level 2-PSA can support severe accident management programmes, i.e. the development, implementation, training and optimisation of accident management strategies and measures. For the most part, the presented material reflects the state in 1996. Current Level 2 PSA results and methodologies are reviewed and evaluated with respect to plant type specific and generic insights. Approaches and practices for using PSA results in the regulatory context and for supporting severe accident management programmes by input from level 2 PSAs are examined. The work is based on information contained in: PSA procedure guides, PSA review guides and regulatory guides for the use of PSA results in risk informed decision making; plant specific PSAs and PSA related literature exemplifying specific procedures, methods, analytical models, relevant input data and important results, use of computer codes and results of code calculations. The PSAs are evaluated with respect to results and insights. In the conclusion section, the present state of risk informed decision making, in particular in the level 2 domain, is described and substantiated by relevant examples

  1. Characteristics Studies of 125I- and total PSA antibody's Binding with prostate specific antigen (PSA) in Human Uterus Tumors

    International Nuclear Information System (INIS)

    Al-Mudaffar, S.; Al-Salihi, J.

    2005-01-01

    Two groups of uterus tumors (benign and malignant) postmenopausal patients were used to investigate the presence of prostate specific antigen (PSA). Preliminary experiments were performed to follow the binding of '1 25 I-anti total PSA antibody with PSA in uterus tissues homogenates of the two groups with their corresponding antigen and found to be (8.8,7.1%) for benign and malignant tumors, respectively. An Immuno Radio Metric Assay (IRMA) procedure was developed for measuring PSA in benign and malignant uterus tumors homogenates. The optimum conditions of the binding of 125 I-anti total PSA antibody with PSA were as follows: PSA concentration (150,200 μg protein),tracer antibody concentration (125,250 μg protein), p H (7.6,7.2), temp (15,25?C) and time (1.5 hrs) for postmenopausal benign and malignant uterus tumors tissue homogenates, respectively. The use of different concentrations of Na + and Mg 2+ ions were shown to cause an increase in the binding at concentration of (125,75 mΜ) of Na 1+ ions (75,225 mΜ) of Mg 2+ ions for benign and malignant uterus tumors homogenates, respectively, while the use of different concentrations of urea and polyethylene glycol (PEG) Caused a decrease in the binding with the increase in the concentration of each of urea and PEG in the both cases

  2. PSA Level 2 activities for RBMK reactors

    International Nuclear Information System (INIS)

    Gubler, R.

    1998-01-01

    Probabilistic safety analyses (PSAs) of the boiling water graphite moderated pressure tube reactors (RBMKs) have been developed only recently and they are limited to Level 1. Activities at the IAEA were first motivated because of the difficulties to characterize core damage for RBMK reactors. Core damage probability is used in documents of the IAEA as a convenient single valued measure, for example for probabilistic safety criteria. The limited number of PSAs that have been completed for the RBMK reactors have shown that several special features of these channel type reactors necessitate revisiting of the characterization of core damage for these reactors. Furthermore, it has become increasingly evident that detailed deterministic analysis of DBAs and beyond design basis accidents reveal considerable insights into RBMK response to various accident conditions. These analyses can also help in better characterizing the outstanding phenomenological uncertainties, improved EOPs and AM strategies, including potential risk-beneficial accident negative backfits. The deterministic efforts should be focused first on elucidating accident progression processes and phenomena, and second on finding, qualifying and implementing procedures to minimize the risk of severe accident states The IAEA PSA procedures were mainly developed in New of vessel type LWRs, and would therefore require extensions to make them directly applicable. to channel type reactors. (author) (author)

  3. Clinical outcomes and nadir prostate-specific antigen (PSA) according to initial PSA levels in primary androgen deprivation therapy for metastatic prostate cancer.

    Science.gov (United States)

    Kitagawa, Yasuhide; Ueno, Satoru; Izumi, Kouji; Kadono, Yoshifumi; Mizokami, Atsushi; Hinotsu, Shiro; Akaza, Hideyuki; Namiki, Mikio

    2016-03-01

    To investigate the clinical outcomes of metastatic prostate cancer patients and the relationship between nadir prostate-specific antigen (PSA) levels and different types of primary androgen deprivation therapy (PADT). This study utilized data from the Japan Study Group of Prostate Cancer registry, which is a large, multicenter, population-based database. A total of 2982 patients treated with PADT were enrolled. Kaplan-Meier analysis was used to compare progression-free survival (PFS) and overall survival (OS) in patients treated using combined androgen blockade (CAB) and non-CAB therapies. The relationships between nadir PSA levels and PADT type according to initial serum PSA levels were also investigated. Among the 2982 enrolled patients, 2101 (70.5 %) were treated with CAB. Although CAB-treated patients had worse clinical characteristics, their probability of PFS and OS was higher compared with those treated with a non-CAB therapy. These results were due to a survival benefit with CAB in patients with an initial PSA level of 500-1000 ng/mL. Nadir PSA levels were significantly lower in CAB patients than in non-CAB patients with comparable initial serum PSA levels. A small survival benefit for CAB in metastatic prostate cancer was demonstrated in a Japanese large-scale prospective cohort study. The clinical significance of nadir PSA levels following PADT was evident, but the predictive impact of PSA nadir on OS was different between CAB and non-CAB therapy.

  4. Regulatory review of probabilistic safety assessment (PSA) Level 2

    International Nuclear Information System (INIS)

    2001-07-01

    Probabilistic safety assessment (PSA) is increasingly being used as part of the decision making process to assess the level of safety of nuclear power plants. The methodologies in use are maturing and the insights gained from the PSAs are being used along with those from deterministic analysis. Many regulatory authorities consider the current state of the art in PSA to be sufficiently well developed for results to be used centrally in the regulatory decision making process-referred to as risk informed regulation. For these applications to be successful, it will be necessary for the regulatory authority to have a high degree of confidence in the PSA. However, at the 1994 IAEA Technical Committee Meeting on Use of PSA in the Regulatory Process and at the OECD Nuclear Energy Agency Committee for Nuclear Regulatory Activities (CNRA) 'Special Issues' meeting in 1997 on Review Procedures and Criteria for Different Regulatory Applications of PSA, it was recognized that formal regulatory review guidance for PSA did not exist. The senior regulators noted that there was a need to produce some international guidance for reviewing PSAs to establish an agreed basis for assessing whether important technological and methodological issues in PSAs are treated adequately and to verify that conclusions reached are appropriate. In 1997, the IAEA and OECD Nuclear Energy Agency agreed to produce, in cooperation, guidance on Regulatory Review of PSA. This led to the publication of IAEA-TECDOC-1135 on the Regulatory Review of Probabilistic Safety Assessment (PSA) Level 1, which gives advice for the review of Level 1 PSA for initiating events occurring at power plants. This TECDOC extends the coverage to address the regulatory review of Level 2 PSA.These publications are intended to provide guidance to regulatory authorities on how to review the PSA for a nuclear power plant to gain confidence that it has been carried out to an acceptable level of quality so that it can be used as the

  5. Development of level 2 PSA technology

    International Nuclear Information System (INIS)

    Kim, Dong Ha; Park, Soo Yong; Kim, See Darl; Song, Yong Mann; Ahn, Kwang Il; Park, Jae Wu; Jin, Young Ho.

    1997-07-01

    The objective of this project is the development of the computer code system for level 2 probabilistic safety assessment (PSA) of nuclear power plants. The scope of the project can be divided into three areas. The first area is to develop the computer code (CONPAS) which can quantify the accident progression event trees. CONPAS beta version has been developed this year and it is comprised of four modules : 1) EDITOR for generating the event tree logic diagrams and 1) COMPUTER for event tree quantification and for additional use of the calculated results. 3) TEXT EDITOR and 4) CODE PLOTTER. Comparing with the existing computer code, the present code provides a flexible code reusability and user interface, convenient edition of logic diagram, data operation, and systematic quantification of the results. The methodology development of containment structural analysis is the second area. The specific tasks included the collection and analysis of the containment failure modes for the various containment types, and the methodology establishment for the containment structure analysis. Over twenty large dry PWR containments, the database for containment failure mode and pressure has been constructed and the simplified fragility model has been proposed to calculate the containment failure probability. They will be used as an important input not only in the containment analysis but also in the source term analysis. For the last, source term analyzing methodology and its applied computer code that is named as 'KORSOR' are developed. KORSOR which used parametric model approach combined modules which consist of accident sequence input module via user's logic rule, random sample generating module, parametric database module, and source term uncertainty quantification module. The characteristics of parametric data which use din the source term analyzing model is analyzed and the constructing idea and example for the parametric database is suggested. (author). 67 refs., 66 tabs

  6. Results of level 1 PSA in Trillo 1 NPP

    International Nuclear Information System (INIS)

    Gomez, F.; Lopez, C.

    1998-01-01

    In July 1991, C. N. Trillo I was requested by the Spanish Regulatory Body (CSN) to perform a PSA that should include: - Level 1 PSA at power - Internal flooding analysis - Level 2 PSA including containment capacity analysis. - External event analyses (fires, external flooding, seismic events and other external events) - Risk analysis for off power conditions (shutdown and low power) - Risk analysis due to other sources of radioactivity In 1992 the Project Plan was issued and the PSA team for the performance of Level 1 PSA was established. Before finishing the Project, it was decided to develop a Phase B to take into account some important modifications that had been accomplished in the Plant and that, probably, could affect the results. Level 1 PSA was finished in March 1998. Both the results of the study and the main conclusions derived from the importance, uncertainty and sensibility analysis performed are presented in this paper. These results de not include the internal flooding analysis conclusions and correspond to PSA revision 0 that is currently being evaluated by the Spanish Regulatory Body. (Author)

  7. Porous Silicon Antibody Microarrays for Quantitative Analysis: Measurement of Free and Total PSA in Clinical Plasma Samples

    Science.gov (United States)

    Tojo, Axel; Malm, Johan; Marko-Varga, György; Lilja, Hans; Laurell, Thomas

    2014-01-01

    The antibody microarrays have become widespread, but their use for quantitative analyses in clinical samples has not yet been established. We investigated an immunoassay based on nanoporous silicon antibody microarrays for quantification of total prostate-specific-antigen (PSA) in 80 clinical plasma samples, and provide quantitative data from a duplex microarray assay that simultaneously quantifies free and total PSA in plasma. To further develop the assay the porous silicon chips was placed into a standard 96-well microtiter plate for higher throughput analysis. The samples analyzed by this quantitative microarray were 80 plasma samples obtained from men undergoing clinical PSA testing (dynamic range: 0.14-44ng/ml, LOD: 0.14ng/ml). The second dataset, measuring free PSA (dynamic range: 0.40-74.9ng/ml, LOD: 0.47ng/ml) and total PSA (dynamic range: 0.87-295ng/ml, LOD: 0.76ng/ml), was also obtained from the clinical routine. The reference for the quantification was a commercially available assay, the ProStatus PSA Free/Total DELFIA. In an analysis of 80 plasma samples the microarray platform performs well across the range of total PSA levels. This assay might have the potential to substitute for the large-scale microtiter plate format in diagnostic applications. The duplex assay paves the way for a future quantitative multiplex assay, which analyses several prostate cancer biomarkers simultaneously. PMID:22921878

  8. PSA LEVEL 3 DAN IMPLEMENTASINYA PADA KAJIAN KESELAMATAN PWR

    Directory of Open Access Journals (Sweden)

    Pande Made Udiyani

    2015-03-01

    Full Text Available Kajian keselamatan PLTN menggunakan metodologi kajian probabilistik sangat penting selain kajian deterministik. Metodologi kajian menggunakan Probabilistic Safety Assessment (PSA Level 3 diperlukan terutama untuk estimasi kecelakaan parah atau kecelakaan luar dasar desain PLTN. Metode ini banyak dilakukan setelah kejadian kecelakaan Fukushima. Dalam penelitian ini dilakukan implementasi PSA Level 3 pada kajian keselamatan PWR, postulasi kecelakan luar dasar desain PWR AP-1000 dan disimulasikan di contoh tapak Bangka Barat. Rangkaian perhitungan yang dilakukan adalah: menghitung suku sumber dari kegagalan teras yang terjadi, pemodelan kondisi meteorologi tapak dan lingkungan, pemodelan jalur paparan, analisis dispersi radionuklida dan transportasi fenomena di lingkungan, analisis deposisi radionuklida, analisis dosis radiasi, analisis perlindungan & mitigasi, dan analisis risiko. Kajian menggunakan rangkaian subsistem pada perangkat lunak PC Cosyma. Hasil penelitian membuktikan bahwa implementasi metode kajian keselamatan PSA Level 3 sangat efektif dan komprehensif terhadap estimasi dampak, konsekuensi, risiko, kesiapsiagaan kedaruratan nuklir (nuclear emergency preparedness, dan manajemen kecelakaan reaktor terutama untuk kecelakaan parah atau kecelakaan luar dasar desain PLTN. Hasil kajian dapat digunakan sebagai umpan balik untuk kajian keselamatan PSA Level 1 dan PSA Level 2. Kata kunci: PSA level 3, kecelakaan, PWR   Reactor safety assessment of nuclear power plants using probabilistic assessment methodology is most important in addition to the deterministic assessment. The methodology of Level 3 Probabilistic Safety Assessment (PSA is especially required to estimate severe accident or beyond design basis accidents of nuclear power plants. This method is carried out after the Fukushima accident. In this research, the postulations beyond design basis accidentsof PWR AP - 1000 would be taken, and simulated at West Bangka sample site. The

  9. Estimation of the uncertainties considered in NPP PSA level 2

    International Nuclear Information System (INIS)

    Kalchev, B.; Hristova, R.

    2005-01-01

    The main approaches of the uncertainties analysis are presented. The sources of uncertainties which should be considered in PSA level 2 for WWER reactor such as: uncertainties propagated from level 1 PSA; uncertainties in input parameters; uncertainties related to the modelling of physical phenomena during the accident progression and uncertainties related to the estimation of source terms are defined. The methods for estimation of the uncertainties are also discussed in this paper

  10. Upgrade of internal events PSA model using the AESJ level-1 PSA standard for operating state

    International Nuclear Information System (INIS)

    Sato, Teruyoshi; Yoneyama, Mitsuru; Hirokawa, Naoki; Sato, Chikahiro; Sato, Eisuke; Tomizawa, Shigeatsu

    2009-01-01

    In 2003, the Atomic Energy Society of Japan (AESJ) started to develop the Level-1 Probabilistic Safety Assessment (PSA) standard of internal events for operating state (AESJ standard). The AESJ standard has been finished to be asked for public comment. Using the AESJ standard (draft version), the authors have upgraded the PSA model for Tokyo Electric Power Company (TEPCO) BWR-5 plant not only to reflect latest knowledge but also to ensure high quality of PSA model (not yet peer-reviewed) for the purpose of better operation and maintenance management of TEPCO BWR plants. For example, the categorization of structures, systems and components (SSCs) will be performed to improve nuclear reactor safety using information of risk importance. (author)

  11. Regulatory review of probabilistic safety assessment (PSA) level 1

    International Nuclear Information System (INIS)

    2000-02-01

    Probabilistic safety assessment (PSA) is increasingly being used as part of the decision making process to assess the level of safety of nuclear power plants. The methodologies in use are maturing and the insights gained from the PSAs are being used along with those from the deterministic analysis. Many regulatory authorities consider that the current state of the art in PSA (especially Level 1 PSA) is sufficiently well developed that it can be used centrally in the regulatory decision making process - referred to as 'risk informed regulation'. For these applications to be successful, it will be necessary for regulatory authorities to have a high degree of confidence in PSA. However, at the IAEA Technical Committee Meeting on Use of PSA in the Regulatory Process in 1994 and at the OECD Nuclear Energy Agency Committee for Nuclear Regulatory Activities (CNRA) 'Special Issues' Meeting in 1997 on Review Procedures and Criteria for Different Regulatory Applications of PSA, it was recognized that formal regulatory review guidance for PSA did not exist. The senior regulators noted that there was a need to produce some international guidance for reviewing PSAs to establish an agreed basis for assessing whether important technological and methodological issues in PSAs are treated adequately and to verify that conclusions reached are appropriate. In 1997 the IAEA and OECD Nuclear Energy Agency agreed to produce in co-operation a technical document on the regulatory review of PSA. This publication is intended to provide guidance to regulatory authorities on how to review the PSA for a nuclear power plant to gain confidence that it has been carried out to an acceptable standard so that it can be used as the basis for taking risk informed decisions within a regulatory decision making process. The document gives guidance on how to set about reviewing a PSA and on the technical issues that need to be addressed. This publication gives guidance for the review of Level 1 PSA for

  12. Towards a PSA harmonization French-Belgian comparison of the level 1 PSA for two similar PWR types

    International Nuclear Information System (INIS)

    Dupuy, P.; Corenwinder, F.; Lanore, J.M.; Gryffroy, D.; Gelder, P. de; Hulsmans, M.

    2002-06-01

    In the framework of the cooperation between French and Belgian regulatory authorities, a PSA (Probabilistic Safety Assessment) comparison exercise has been carried out for several years. This comparison deals with two PSA level 1 studies for internal events, performed for both power and shutdown states: the French PSA of the 900 MWe-series PWR, and the Belgian PSA of the Tihange 1 PWR, which both concern PWRs with a similar Framatome design. The purpose of this paper is to describe the PSA comparison methodology and to present, in a qualitative way, an overview of the insights obtained up to now. It also shows that such an 'a posteriori' benchmark exercise turns out to be a step towards PSA harmonization, and gives more confidence in the results of plant specific PSA when used for applications like precursor analysis or evaluations of importance to safety. (authors)

  13. Development of an immunoradiometric method for the measurement of total PSA

    International Nuclear Information System (INIS)

    Venkatesh, M.; Korde, A.; Bapat, K.; Shukla, A.; Pillai, M.R.A.

    1999-01-01

    Development of an IRMA for total-PSA was taken up in our laboratories (Isotope Division, Bhabha Atomic Research Centre, Mumbai, India) and efforts were made to obtain monoclonals for PSA at our laboratory. Following the guidelines laid at the first meeting of this CRP we have used the reagents supplied by the Agency as well as our inhouse reagents, and attempted to develop assay procedures for measuring total-PSA in human sera

  14. [Rates of total and free PSA prescriptions in France (2012-2014)].

    Science.gov (United States)

    Tuppin, Philippe; Leboucher, Claire; Peyre-Lanquar, Gabrielle; Lamy, Pierre-Jean; Gabach, Pierre; Rébillard, Xavier

    2017-10-01

    In 2010, the French Haute Autorité de santé (National Health Authority) confirmed the limited value of prostate cancer (PCa) screening by total prostate-specific antigen (PSA) assay. This study was designed to determine the modalities of ordering total PSA or free PSA assays (in the absence of PCa) according to various parameters and the corresponding sums reimbursed. Men aged 40 years and older covered by the national health insurance general scheme (73% of the French population) between 2012 and 2014 were selected. Data were derived from the Système national d'information inter-régimes de l'assurance maladie (Sniiram) (National health insurance information system) database. In 2014, 27% of the 11.6 million men 40 years and older underwent at least one total PSA assay and 5.6% underwent at least one free PSA assay, with marked variations according to the presence or absence of treated lower urinary tract symptoms (LUTS) (53% and 15% vs 24% and 5%) and from one administrative department to another. The peak total PSA assay rate was observed between the ages of 65 and 74 years: 64% of men with LUTS, 46% without LUTS. Between 2012 and 2014, men in whom at least one PSA assay had been performed underwent a mean of 1.8 total PSA assays and 1.7 free PSA assays, with means of 2.3 and 2, respectively, in the presence of LUTS. General practice specialists ordered 91% of the PSA tests reimbursed in 2014 (92% for total PSA and 87% for free PSA) and urologists ordered 4% of reimbursed tests. The total sum reimbursed was €28.5 million, comprising €8.7 million for free PSA. An average of 10 laboratory tests was performed at the same time as the PSA assay in the absence of treated LUTS. Total PSA and free PSA assays are performed in a large number of men, although the value of these tests as first-line test before biopsy remains controversial. These PSA assays are associated with many other laboratory tests looking for possible abnormalities, especially in younger

  15. The percentage of prostate-specific antigen (PSA) isoform [-2]proPSA and the Prostate Health Index improve the diagnostic accuracy for clinically relevant prostate cancer at initial and repeat biopsy compared with total PSA and percentage free PSA in men aged ≤65 years.

    Science.gov (United States)

    Boegemann, Martin; Stephan, Carsten; Cammann, Henning; Vincendeau, Sébastien; Houlgatte, Alain; Jung, Klaus; Blanchet, Jean-Sebastien; Semjonow, Axel

    2016-01-01

    To prospectively test the diagnostic accuracy of the percentage of prostate specific antigen (PSA) isoform [-2]proPSA (%p2PSA) and the Prostate Health Index (PHI), and to determine their role for discrimination between significant and insignificant prostate cancer at initial and repeat prostate biopsy in men aged ≤65 years. The diagnostic performance of %p2PSA and PHI were evaluated in a multicentre study. In all, 769 men aged ≤65 years scheduled for initial or repeat prostate biopsy were recruited in four sites based on a total PSA (t-PSA) level of 1.6-8.0 ng/mL World Health Organization (WHO) calibrated (2-10 ng/mL Hybritech-calibrated). Serum samples were measured for the concentration of t-PSA, free PSA (f-PSA) and p2PSA with Beckman Coulter immunoassays on Access-2 or DxI800 instruments. PHI was calculated as (p2PSA/f-PSA × √t-PSA). Uni- and multivariable logistic regression models and an artificial neural network (ANN) were complemented by decision curve analysis (DCA). In univariate analysis %p2PSA and PHI were the best predictors of prostate cancer detection in all patients (area under the curve [AUC] 0.72 and 0.73, respectively), at initial (AUC 0.67 and 0.69) and repeat biopsy (AUC 0.74 and 0.74). t-PSA and %f-PSA performed less accurately for all patients (AUC 0.54 and 0.62). For detection of significant prostate cancer (based on Prostate Cancer Research International Active Surveillance [PRIAS] criteria) the %p2PSA and PHI equally demonstrated best performance (AUC 0.70 and 0.73) compared with t-PSA and %f-PSA (AUC 0.54 and 0.59). In multivariate analysis PHI we added to a base model of age, prostate volume, digital rectal examination, t-PSA and %f-PSA. PHI was strongest in predicting prostate cancer in all patients, at initial and repeat biopsy and for significant prostate cancer (AUC 0.73, 0.68, 0.78 and 0.72, respectively). In DCA for all patients the ANN showed the broadest threshold probability and best net benefit. PHI as single parameter

  16. Variability of assay methods for total and free PSA after WHO standardization.

    Science.gov (United States)

    Foj, L; Filella, X; Alcover, J; Augé, J M; Escudero, J M; Molina, R

    2014-03-01

    The variability of total PSA (tPSA) and free PSA (fPSA) results among commercial assays has been suggested to be decreased by calibration to World Health Organization (WHO) reference materials. To characterize the current situation, it is necessary to know its impact in the critical cutoffs used in clinical practice. In the present study, we tested 167 samples with tPSA concentrations of 0 to 20 μg/L using seven PSA and six fPSA commercial assays, including Access, ARCHITECT i2000, ADVIA Centaur XP, IMMULITE 2000, Elecsys, and Lumipulse G1200, in which we only measured tPSA. tPSA and fPSA were measured in Access using the Hybritech and WHO calibrators. Passing-Bablok analysis was performed for PSA, and percentage of fPSA with the Hybritech-calibrated access comparison assay. For tPSA, relative differences were more than 10 % at 0.2 μg/L for ARCHITECT i2000, and at a critical concentration of 3, 4, and 10 μg/L, the relative difference was exceeded by ADVIA Centaur XP and WHO-calibrated Access. For percent fPSA, at a critical concentration of 10 %, the 10 % relative difference limit was exceeded by IMMULITE 2000 assay. At a critical concentration of 20 and 25 %, ADVIA Centaur XP, ARCHITECT i2000, and IMMULITE 2000 assays exceeded the 10 % relative difference limit. We have shown significant discordances between assays included in this study despite advances in standardization conducted in the last years. Further harmonization efforts are required in order to obtain a complete clinical concordance.

  17. Reappraisal of the application of total and free PSA estimation for diagnosis of prostate cancer in Chinese

    International Nuclear Information System (INIS)

    Chu, L.S.; Liu, R.S.; Yang, C.S.; Chen, G.K.; Liao, S.Q.

    2002-01-01

    Objectives: Prostate-specific antigen (PSA) test has become one of the most cost effective tools for detecting early prostate cancer. In general, a diagnosis of prostate cancer is uncommon at serum levels of total PSA (TPSA) at or below 4 ng/mL and is common at levels above 10 ng/mL. The diagnostic gray zone is between 4.0 and 10.0 ng/mL, where the differential diagnosis of prostate cancer is most difficult. For such patients ratio of free-to-total PSA (F/TPSA) can be useful in differentiating prostate cancer from benign prostate hypertrophy (BPH). However, screen for prostate cancer with PSA remains controversial. Thirty-five percent of the patients with clinically localized prostate cancer present with serum PSA levels below 4 ng/mL. What is the optimal 'reflex' total PSA at which we should implement use of the F/T PSA? The purpose of this study is to assess the usefulness of F/TPSA in patients with TPSA less than 4 ng/mL. Methods: A total of 101 high-risk patients of prostate cancer underwent transrectal ultrasonography and biopsy or transurethral resection of prostate were studied. Sixty-eight patients were proved to have BPH only and 33 patients were proved to have prostate cancer. TPSA and F/TPSA were determined using a immunoradiometric assay (PSA-RIACT, FPSA-RIACT, CIS). The appropriate cut-off value of F/TPSA in diagnosis of prostate cancer determined by receiver-operating characteristic (ROC) curve was 0.19. Results: The TPSA value of the subjects ranged from 0 to 15 ng/mL. Seventeen cases (26%) of prostate cancer were disclosed in 65 patients with TPSA > 4 ng/mL. Thirty-six patients had TPSA 0.19 were proved to have prostate cancer. Conclusion: Thirty-nine per cent of high-risk patients with TPSA < 4.0 ng/mL and F/T PSA < 0.19 was found to have prostate cancer. F/T PSA should be determined in Chinese patients with TPSA < 10 ng/mL instead of the algorithm of combined use of F/T PSA and TPSA between 4-10 ng/mL

  18. IC modelling in the IRSN EPR level 1 PSA

    International Nuclear Information System (INIS)

    Delache, J.

    2012-01-01

    Today in France, an EPR (European Pressurized Water Reactor) Unit is under construction at the Flamanville site. The creation authorization was granted in April 2007 and the plant commissioning is planned for 2012. The plant operator (EDF) provided for the construction license several PSA (Probabilistic Safety Assessment) studies. IRSN, as TSO (Technical Safety Organisation), wishes to dispose of the appropriate knowledge and tools for the independent verification of the operator studies and so developed its own model of PSA level 1. The goal is not to rebuild the plant operator PSA (with a full scope...) but to dispose of a simplified model able to clearly point out specific important issues. In the IRSN model a particular effort has recently been done on the Digital IC modelling. The IC (Instrumentation and Control) is modelled in the IRSN EPR PSA by using Fault Trees. Instead, EDF EPR PSA applies the COMPACT model to simplify the command and instrumentation logics. The IRSN model is more detailed in order to be more accurate in the global analysis of the Digital IC. For instance the communication ways between automates are considered as well as the failure of support systems. The model is still under development mainly in order to define the CCF (Common Cause Failure) which may be considered. (authors)

  19. Analysis of Serum Total and Free PSA Using Immunoaffinity Depletion Coupled to SRM: Correlation with Clinical Immunoassay Tests

    Science.gov (United States)

    Liu, Tao; Hossain, Mahmud; Schepmoes, Athena A.; Fillmore, Thomas L.; Sokoll, Lori J.; Kronewitter, Scott R.; Izmirlian, Grant; Shi, Tujin; Qian, Wei-Jun; Leach, Robin J.; Thompson, Ian M.; Chan, Daniel W.; Smith, Richard D.; Kagan, Jacob; Srivastava, Sudhir; Rodland, Karin D.; Camp, David G.

    2012-01-01

    Recently, selected reaction monitoring mass spectrometry (SRM-MS) has been more frequently applied to measure low abundance biomarker candidates in tissues and biofluids, owing to its high sensitivity and specificity, simplicity of assay configuration, and exceptional multiplexing capability. In this study, we report for the first time the development of immunoaffinity depletion-based workflows and SRM-MS assays that enable sensitive and accurate quantification of total and free prostate-specific antigen (PSA) in serum without the requirement for specific PSA antibodies. Low ng/mL level detection of both total and free PSA was consistently achieved in both PSA-spiked female serum samples and actual patient serum samples. Moreover, comparison of the results obtained when SRM PSA assays and conventional immunoassays were applied to the same samples showed good correlation in several independent clinical serum sample sets. These results demonstrate that the workflows and SRM assays developed here provide an attractive alternative for reliably measuring candidate biomarkers in human blood, without the need to develop affinity reagents. Furthermore, the simultaneous measurement of multiple biomarkers, including the free and bound forms of PSA, can be performed in a single multiplexed analysis using high-resolution liquid chromatographic separation coupled with SRM-MS. PMID:22846433

  20. Improvement of level-1 PSA computer code package

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Tae Woon; Park, C. K.; Kim, K. Y.; Han, S. H.; Jung, W. D.; Chang, S. C.; Yang, J. E.; Sung, T. Y.; Kang, D. I.; Park, J. H.; Lee, Y. H.; Kim, S. H.; Hwang, M. J.; Choi, S. Y.

    1997-07-01

    This year the fifth (final) year of the phase-I of the Government-sponsored Mid- and Long-term Nuclear Power Technology Development Project. The scope of this subproject titled on `The improvement of level-1 PSA Computer Codes` is divided into two main activities : (1) improvement of level-1 PSA methodology, (2) development of applications methodology of PSA techniques to operations and maintenance of nuclear power plant. Level-1 PSA code KIRAP is converted to PC-Windows environment. For the improvement of efficiency in performing PSA, the fast cutset generation algorithm and an analytical technique for handling logical loop in fault tree modeling are developed. Using about 30 foreign generic data sources, generic component reliability database (GDB) are developed considering dependency among source data. A computer program which handles dependency among data sources are also developed based on three stage bayesian updating technique. Common cause failure (CCF) analysis methods are reviewed and CCF database are established. Impact vectors can be estimated from this CCF database. A computer code, called MPRIDP, which handles CCF database are also developed. A CCF analysis reflecting plant-specific defensive strategy against CCF event is also performed. A risk monitor computer program, called Risk Monster, are being developed for the application to the operation and maintenance of nuclear power plant. The PSA application technique is applied to review the feasibility study of on-line maintenance and to the prioritization of in-service test (IST) of motor-operated valves (MOV). Finally, the root cause analysis (RCA) and reliability-centered maintenance (RCM) technologies are adopted and applied to the improvement of reliability of emergency diesel generators (EDG) of nuclear power plant. To help RCA and RCM analyses, two software programs are developed, which are EPIS and RAM Pro. (author). 129 refs., 20 tabs., 60 figs.

  1. Improvement of level-1 PSA computer code package

    International Nuclear Information System (INIS)

    Kim, Tae Woon; Park, C. K.; Kim, K. Y.; Han, S. H.; Jung, W. D.; Chang, S. C.; Yang, J. E.; Sung, T. Y.; Kang, D. I.; Park, J. H.; Lee, Y. H.; Kim, S. H.; Hwang, M. J.; Choi, S. Y.

    1997-07-01

    This year the fifth (final) year of the phase-I of the Government-sponsored Mid- and Long-term Nuclear Power Technology Development Project. The scope of this subproject titled on 'The improvement of level-1 PSA Computer Codes' is divided into two main activities : 1) improvement of level-1 PSA methodology, 2) development of applications methodology of PSA techniques to operations and maintenance of nuclear power plant. Level-1 PSA code KIRAP is converted to PC-Windows environment. For the improvement of efficiency in performing PSA, the fast cutset generation algorithm and an analytical technique for handling logical loop in fault tree modeling are developed. Using about 30 foreign generic data sources, generic component reliability database (GDB) are developed considering dependency among source data. A computer program which handles dependency among data sources are also developed based on three stage bayesian updating technique. Common cause failure (CCF) analysis methods are reviewed and CCF database are established. Impact vectors can be estimated from this CCF database. A computer code, called MPRIDP, which handles CCF database are also developed. A CCF analysis reflecting plant-specific defensive strategy against CCF event is also performed. A risk monitor computer program, called Risk Monster, are being developed for the application to the operation and maintenance of nuclear power plant. The PSA application technique is applied to review the feasibility study of on-line maintenance and to the prioritization of in-service test (IST) of motor-operated valves (MOV). Finally, the root cause analysis (RCA) and reliability-centered maintenance (RCM) technologies are adopted and applied to the improvement of reliability of emergency diesel generators (EDG) of nuclear power plant. To help RCA and RCM analyses, two software programs are developed, which are EPIS and RAM Pro. (author). 129 refs., 20 tabs., 60 figs

  2. Diagnostic value of serum free PSA and the ratio of free to total PSA in the diagnosis of prostate cancer

    International Nuclear Information System (INIS)

    Qiu Ningyan; Zhang Jingxin; Wu Jinchang; Gong Yiming; Li Huiping

    2005-01-01

    In order to evaluate the value of free prostate specific antigen (FPSA) and F/T PSA ratio in differential diagnosis of benign prostate hyperplasia (BPH) from prostate cancer (PC), serum FPSA and TPSA levels were measured in 85 patients with PC, 97 BPH and 89 healthy volunteers by chemiluminescence enzyme immunoassay (CLEIA), and the ratio of F/T PSA was calculated. The results showed that serum FPSA and TPSA levels were increased in healthy volunteers of 41-88 years old and were significantly higher in healthy volunteers of 61-88 years old than that in 20-40 gear old (P 10.0 μg/L were 65.0%, 30.9% and 4.1%, respectively, while they were 5.9%, 20.0% and 74.1% in PC patients (P<0.01). When the TPSA value was between 4.0-10.0 μg/L and the ratio of F/T PSA was at 0.10 and below, the probability of PC was larger(88.9%). But the ratio of F/T PSA was at 0.25 and above, the probability of PC was smaller(6.20%). Serum FPSA and TPSA both increased with age in healthy volunteers of 41-88 years old and were positively correlated with age. There were about 30.9% of BPH and 20.0% of PC patients with overlapping of TPSA level. Our conclusion is that the F/T PSA ratio can significantly enhance the specificity for PC diagnosis, especially when the TPSA is within the diagnostic gray zone. (authors)

  3. Analysis of Serum Total and Free PSA Using Immunoaffinity Depletion Coupled to SRM: Correlation with Clinical Immunoassay Tests

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Tao; Hossain, Mahmud; Schepmoes, Athena A.; Fillmore, Thomas L.; Sokoll, Lori J.; Kronewitter, Scott R.; Izmirlian, Grant; Shi, Tujin; Qian, Weijun; Leach, Robin; Thompson, Ian M.; Chan, Daniel W.; Smith, Richard D.; Kagan, Jacob; Srinivastava, Sudhir; Rodland, Karin D.; Camp, David G.

    2012-08-03

    Sandwich immunoassay is the standard technique used in clinical labs for quantifying protein biomarkers for disease detection, monitoring and therapeutic intervention. Albeit highly sensitive, the development of a specific immunoassay is rather time-consuming and associated with extremely high cost due to the requirement for paired immunoaffinity reagents of high specificity. Recently, mass spectrometry-based methods, specifically selected reaction monitoring mass spectrometry (SRM-MS), have been increasingly applied to measure low abundance biomarker candidates in tissue and biofluids, owing to high sensitivity and specificity, simplicity of assay configuration, and great multiplexing capability. In this study, we report for the first time the development of immunoaffinity depletion-based workflows and SRM-MS assays that enable sensitive and accurate quantification of total and free prostate-specific antigen (PSA) in serum without the requirement for specific PSA antibodies. With stable isotope dilution and external calibration, low ng/mL level detection of both total and free PSA was consistently achieved in both PSA-spiked female serum samples and actual patient serum samples. Moreover, comparison of the results obtained when SRM PSA assays and conventional immunoassays were applied to the same samples showed very good correlation (R2 values ranging from 0.90 to 0.99) in several independent clinical serum sample sets, including a set of 33 samples assayed in a blinded test. These results demonstrate that the workflows and SRM assays developed here provide an attractive alternative for reliably measuring total and free PSA in human blood. Furthermore, simultaneous measurement of free and total PSA and many other biomarkers can be performed in a single analysis using high-resolution liquid chromatographic separation coupled with SRM-MS.

  4. Recent Developments in Level 2 PSA and Severe Accident Management

    International Nuclear Information System (INIS)

    Ang, Ming Leang; Shepherd, Charles; Gauntt, Randall; Landgren, Vickie; Van Dorsselaere, Jean Pierre; Chaumont, Bernard; Raimond, Emmanuel; Magallon, Daniel; Prior, Robert; Mlady, Ondrej; Khatib-Rahbar, Mohsen; Lajtha, Gabor; Tinkler, Charles; Siu, Nathan

    2007-01-01

    In 1997, CSNI WGRISK produced a report on the state of the art in Level 2 PSA and severe accident management - NEA/CSNI/R(1997)11. Since then, there have been significant developments in that more Level 2 PSAs have been carried out worldwide for a variety of nuclear power plant designs including some that were not addressed in the original report. In addition, there is now a better understanding of the severe accident phenomena that can occur following core damage and the way that they should be modelled in the PSA. As requested by CSNI in December 2005, the objective of this study was to produce a report that updates the original report and gives an account of the developments that have taken place since 1997. The aim has been to capture the most significant new developments that have occurred rather than to provide a full update of the original report, most of which is still valid. This report is organised using the same structure as the original report as follows: Chapter 2: Summary on state of application, results and insights from recent Level 2 PSAs. Chapter 3: Discussion on key severe accident phenomena and modelling issues, identification of severe accident issues that should be treated in Level 2 PSAs for accident management applications, review of severe accident computer codes and the use of these codes in Level 2 PSAs. Chapter 4: Review of approaches and practices for accident management and SAM, evaluation of actions in Level 2 PSAs. Chapter 5: Review of available Level 2 PSA methodologies, including accident progression event tree / containment event tree development. Chapter 6: Aspects important to quantification, including the use of expert judgement and treatment of uncertainties. Chapter 7: Examples of the use of the results and insights from the Level 2 PSA in the context of an integrated (risk informed) decision making process

  5. Severe accident analysis for level 2 PSA of SMART reactor

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jin Yong; Lee, Jeong Hun; Kim, Jong Uk; Yoo, Tae Geun; Chung, Soon Il; Kim, Min Gi [FNC Technology Co., Seoul (Korea, Republic of)

    2010-12-15

    The objectives of this study are to produce data for level 2 PSA and evaluation results of severe accident by analyzing severe accident sequence of transient events, producing fault tree of containment systems and evaluating direct containment heating of the SMART. In this project, severe accident analysis results were produced for general transient, loss of feedwater, station blackout, and steam line break events, and based on the results, design safety of SMART was verified. Also, direct containment heating phenomenon of the SMART was evaluated using TCE methodology. For level 2 PSA, fault tree of the containment isolation system, reactor cavity flooding system, plant chilled water system, and reactor containment building HVAC system was produced and analyzed

  6. Correlation of serum androgens and pituitary hormone levels with serum PSA less than 2.5 ng/ml.

    Science.gov (United States)

    Sofikerim, Mustafa; Oruç, Ozgür; Eskicorapci, Sadettin; Guliyev, Fuat; Ozen, Haluk

    2007-07-27

    The aim of this clinical study was to determine whether there is a relationship between total serum testosterone, free testosterone, FSH (Follicle-Stimulating Hormone), LH (Luteinizing Hormone) and serum prostate specific antigen (PSA) levels. We postulated that such a correlation existed then the use of hormone specific reference ranges might enhance the usefullness of PSA concentrations 40 years of age visiting our urology outpatient clinics. PSA was correlated to age (r = 0.23, p = 0.019), but there none between serum testosterone and age. No significant correlation was noted between testosterone or free testosterone and serum PSA levels, and none between serum FSH or LH and PSA. In age specific reference groups (41-49; 50-59; 60-69 years), we found no significant correlation between PSA and hormone concentrations. In this population of eugonadal men with serum PSA values less than 2.5 ng/ml, serum androgens and pituitary hormones do not appear to correlate with serum PSA.

  7. Development of the Level 1 PSA Model for PGSFR Regulatory

    International Nuclear Information System (INIS)

    Na, Hyun Ju; Lee, Yong Suk; Shin, Andong; Suh, Nam Duk

    2014-01-01

    SFR (sodium-cooled fast reactor) is Gen-IV nuclear energy system, which is designed for stability, sustainability and proliferation resistance. KALIMER-600 and PGSFR (Prototype Gen-IV SFR) are under development in Korea with enhanced passive safety concepts, e.g. passive reactor shutdown, passive residual heat removal, and etc. Risk analysis from a regulatory perspective is necessary for regulatory body to support the safety and licensing review of SFR. Safety issues should be identified in the early design phase in order to prevent the unexpected cost increase and the delay of PGSFR licensing schedule. In this respect, the preliminary PSA Model of KALIMER-600 had been developed for regulatory. In this study, the development of PSA Level 1 Model is presented. The important impact factors in the risk analysis for the PGSFR, such as Core Damage Frequency (CDF), have been identified and the related safety insights have been derived. The PSA level 1 model for PGSFR regulatory is developed and the risk analysis is conducted. Regarding CDF, LOISF frequency, uncertainty parameter for passive system CCF, loss of 125V DC control center bus and damper CCF are identified as the important factors. Sensitivity analyses show that the CDF would be differentiated (lowered) according to their values

  8. Development of computing code system for level 3 PSA

    International Nuclear Information System (INIS)

    Jeong, Jong Tae; Yu, Dong Han; Kim, Seung Hwan.

    1997-07-01

    Among the various research areas of the level 3 PSA, the effect of terrain on the transport of radioactive material was investigated through wind tunnel experiment. These results will give a physical insight in the development of a new dispersion model. Because there are some discrepancies between the results from Gaussian plume model and those from field test, the effect of terrain on the atmospheric dispersion was investigated by using CTDMPLUS code. Through this study we find that the model which can treat terrain effect is essential in the atmospheric dispersion of radioactive materials and the CTDMPLUS model can be used as a useful tool. And it is suggested that modification of a model and experimental study should be made through the continuous effort. The health effect assessment near the Yonggwang site by using IPE (Individual plant examination) results and its site data was performed. The health effect assessment is an important part of consequence analysis of a nuclear power plant site. The MACCS was used in the assessment. Based on the calculation of CCDF for each risk measure, it is shown that CCDF has a slow slope and thus wide probability distribution in cases of early fatality, early injury, total early fatality risk, and total weighted early fatality risk. And in cases of cancer fatality and population dose within 48km and 80km, the CCDF curve have a steep slope and thus narrow probability distribution. The establishment of methodologies for necessary models for consequence analysis resulting form a server accident in the nuclear power plant was made and a program for consequence analysis was developed. The models include atmospheric transport and diffusion, calculation of exposure doses for various pathways, and assessment of health effects and associated risks. Finally, the economic impact resulting form an accident in a nuclear power plant was investigated. In this study, estimation models for each cost terms that considered in economic

  9. Development of computing code system for level 3 PSA

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Jong Tae; Yu, Dong Han; Kim, Seung Hwan

    1997-07-01

    Among the various research areas of the level 3 PSA, the effect of terrain on the transport of radioactive material was investigated through wind tunnel experiment. These results will give a physical insight in the development of a new dispersion model. Because there are some discrepancies between the results from Gaussian plume model and those from field test, the effect of terrain on the atmospheric dispersion was investigated by using CTDMPLUS code. Through this study we find that the model which can treat terrain effect is essential in the atmospheric dispersion of radioactive materials and the CTDMPLUS model can be used as a useful tool. And it is suggested that modification of a model and experimental study should be made through the continuous effort. The health effect assessment near the Yonggwang site by using IPE (Individual plant examination) results and its site data was performed. The health effect assessment is an important part of consequence analysis of a nuclear power plant site. The MACCS was used in the assessment. Based on the calculation of CCDF for each risk measure, it is shown that CCDF has a slow slope and thus wide probability distribution in cases of early fatality, early injury, total early fatality risk, and total weighted early fatality risk. And in cases of cancer fatality and population dose within 48km and 80km, the CCDF curve have a steep slope and thus narrow probability distribution. The establishment of methodologies for necessary models for consequence analysis resulting form a server accident in the nuclear power plant was made and a program for consequence analysis was developed. The models include atmospheric transport and diffusion, calculation of exposure doses for various pathways, and assessment of health effects and associated risks. Finally, the economic impact resulting form an accident in a nuclear power plant was investigated. In this study, estimation models for each cost terms that considered in economic

  10. Analytical and clinical performances of immunoradiometric assay of total and free PSA developed locally

    International Nuclear Information System (INIS)

    Boucekkine, N.; Korso, R.; Bellazoug, K.; Ferd, N.; Bouyoucef, S.E.; Boudjemai, S.; Benzaid, A.; Bouhila, Z.

    2002-01-01

    A specific assay was developed for total and free PSA (PSAt, PSAf). Both assay use a two site IRMA with polyclonal anti PSA antibodies coated on tubes. Polyclonal antibodies were obtained after rabbit's immunisation using an under skin injection of pure PSA in multiple site. For quantification, two monoclonal antibodies were selected, the first highly specific to free PSA and the second recognising both free and bound PSA. A correlation study was performed comparatively with two commercial kits from CIS Bio and Immunotech. For that purpose, 464 serums samples ranging from 0.5 ng/ml to 3399 ng/ml were used to characterise the analytical performance of the new test. The analytical detection limit of the new test was equal to 0.05 ng/ml for the total PSA and 0.02ng/ml for the free PSA. The within run and between-day coefficients of variation were to 20 ng/ml. For BPH, no significant difference was found between the three test for the ratio PSAf/PSAt using a cut off of 14% (all were>to 14%). For the 120 patients with PC, all PSAt were > to 2 ng/ml. However the mean value of PSAt was higher for the commercial kits (14.74 ng/ml against 12.48ng/ml for the new test) but all ratio of PSAf/PSAt for the 120 newly diagnosed cancer were <14%. In conclusion, our immunoradiometric assay developed locally has a good analytical performance and its outputs are well correlated to clinical findings in prostate disease. Furthermore, a cut off of 14% for the ratio PSAf/PSAt appears to be the most accurate tools to depict a prostate cancer

  11. Correlation of Serum Androgens and Pituitary Hormone Levels with Serum PSA Less Than 2.5 NG/ML

    Directory of Open Access Journals (Sweden)

    Mustafa Sofikerim

    2007-01-01

    Full Text Available The aim of this clinical study was to determine whether there is a relationship between total serum testosterone, free testosterone, FSH (Follicle-Stimulating Hormone, LH (Luteinizing Hormone and serum prostate specific antigen (PSA levels. We postulated that such a correlation existed then the use of hormone specific reference ranges might enhance the usefullness of PSA concentrations <2.5 ng/mL as a marker for prostate cancer.

  12. Evaluation of prostate cancer prevalence in Iranian male population with increased PSA level, a one center experience

    International Nuclear Information System (INIS)

    Moslemi, Mohammad Kazem; Lotfi, Fariborz; Tahvildar, Seyed Ali

    2011-01-01

    This study was conducted to evaluate the incidence of prostate cancer (PCa) in Iranian male patients with increased prostate-specific antigen (PSA), and normal or abnormal digital rectal examination (DRE) that underwent prostate biopsy. From March 2006 to April 2009, a total of 346 consecutive males suspected of having PCa due to increased PSA levels underwent transrectal ultrasonography (TRUS)-guided sextant biopsy of the prostate. The total PSA (tPSA), demographic data, incidence of PCa, benign prostate hyperplasia (BPH), and prostatitis were assessed. The patients were divided into two groups according to their PSA values (group A serum tPSA level, 4–10 ng/mL; group B serum tPSA level, 10.1–20.0 ng/mL). Of the 346 biopsied cases, 193 cases (56%) had PCa, 80 cases (23%) had BPH, and 73 cases (21%) had prostatitis. The mean PSA and the age of the carcinoma group were significantly higher than those of the benign group (P < 0.01). The biopsy results were grouped as PCa, BPH, and prostatitis. Incidence of PCa for group A and group B cases were 115 cases (51%), and 78 cases (65%), respectively. In the case of PCa, BPH, and prostatitis, the mean PSAs were 10.02 ng/mL, 8.76 ng/mL, and 8.41 ng/mL, respectively (P < 0.40). TRUS-guided prostate biopsy and interpretation by a skilled team is highly recommended for early detection of PCa or its ruling-out. It seems that a PSA cutoff value of 4 ng/mL may be applied to the Iranian population. Although the chance of PCa is high in the PSA levels of 4–10 ng/mL, the combination of some data, like age and prostate volume, can decrease the rate of unnecessary prostate biopsies. We recommend prostate biopsy when PSA and/or DRE is elevated in symptomatic patients with obstructive and/or irritative lower urinary tract symptoms (LUTS) such as dysuria, frequency, or nocturia. Due to the very high incidence of PCa in the patients with PSA greater than 10 ng/mL, TRUS-guided biopsy is indicated, whatever the findings on DRE and

  13. Multi-Unit Initiating Event Analysis for a Single-Unit Internal Events Level 1 PSA

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dong San; Park, Jin Hee; Lim, Ho Gon [KAERI, Daejeon (Korea, Republic of)

    2016-05-15

    The Fukushima nuclear accident in 2011 highlighted the importance of considering the risks from multi-unit accidents at a site. The ASME/ANS probabilistic risk assessment (PRA) standard also includes some requirements related to multi-unit aspects, one of which (IE-B5) is as follows: 'For multi-unit sites with shared systems, DO NOT SUBSUME multi-unit initiating events if they impact mitigation capability [1].' However, the existing single-unit PSA models do not explicitly consider multi-unit initiating events and hence systems shared by multiple units (e.g., alternate AC diesel generator) are fully credited for the single unit and ignores the need for the shared systems by other units at the same site [2]. This paper describes the results of the multi-unit initiating event (IE) analysis performed as a part of the at-power internal events Level 1 probabilistic safety assessment (PSA) for an OPR1000 single unit ('reference unit'). In this study, a multi-unit initiating event analysis for a single-unit PSA was performed, and using the results, dual-unit LOOP initiating event was added to the existing PSA model for the reference unit (OPR1000 type). Event trees were developed for dual-unit LOOP and dual-unit SBO which can be transferred from dual- unit LOOP. Moreover, CCF basic events for 5 diesel generators were modelled. In case of simultaneous SBO occurrences in both units, this study compared two different assumptions on the availability of the AAC D/G. As a result, when dual-unit LOOP initiating event was added to the existing single-unit PSA model, the total CDF increased by 1∼ 2% depending on the probability that the AAC D/G is available to a specific unit in case of simultaneous SBO in both units.

  14. Relationship of chronic histologic prostatic inflammation in biopsy specimens with serum isoform [-2]proPSA (p2PSA), %p2PSA, and prostate health index in men with a total prostate-specific antigen of 4-10 ng/ml and normal digital rectal examination.

    Science.gov (United States)

    Lazzeri, Massimo; Abrate, Alberto; Lughezzani, Giovanni; Gadda, Giulio Maria; Freschi, Massimo; Mistretta, Francesco; Lista, Giuliana; Fossati, Nicola; Larcher, Alessandro; Kinzikeeva, Ella; Buffi, Nicolòmaria; Dell'Acqua, Vincenzo; Bini, Vittorio; Montorsi, Francesco; Guazzoni, Giorgio

    2014-03-01

    To investigate the relationship between serum [-2]proPSA (p2PSA) and derivatives with chronic histologic prostatic inflammation (CHPI) in men undergoing prostate biopsy for suspected prostate cancer (PCa). This nested case-control study resulted from an observational prospective trial for the definition of sensibility, specificity, and accuracy of p2PSA, %p2PSA, and Beckman Coulter Prostate Health Index (PHI), in men undergoing prostate biopsy, with a total prostate-specific antigen (PSA) of 4-10 ng/mL and normal digital rectal examination. CHPI was the outcome of interest and defined as the presence of moderate to large infiltration of lymphomononuclear cells with interstitial and/or glandular disruption in absence of PCa. p2PSA, %p2PSA, and PHI were considered the index tests and compared with the established biomarker reference standard tests: tPSA, fPSA, %fPSA. Of 267 patients subjected to prostate biopsy, 73 (27.3%) patients were diagnosed with CHPI. Comparing CHPI with PCa patients, %p2PSA and PHI were found to be significantly lower, whereas fPSA and %fPSA were significantly higher. %p2PSA and PHI were the most accurate predictors of CHPI at biopsy, significantly outperforming tPSA, fPSA, and %fPSA. On the contrary, no significant differences were found in PSA, p2PSA, and derivatives between CHPI and benign prostatic hyperplasia (BPH) patients. Our findings showed that p2PSA, %p2PSA, and PHI values might discriminate PCa from CHPI or BPH, but not CHPI from BPH, in men with a total PSA 4-10 ng/mL and normal digital rectal examination. p2PSA isoform and its derivatives could be useful in clinical decision making to avoid unnecessary biopsies in patients with CHPI and elevated tPSA value. Copyright © 2014 Elsevier Inc. All rights reserved.

  15. A formal treatment of uncertainty sources in a level 2 PSA

    International Nuclear Information System (INIS)

    Ahn, Kwang Il; Yang, Joon Eon

    2003-01-01

    The methodological framework of the level 2 PSA appears to be currently standardized in a formalized fashion, but there have been different opinions on the way the sources of uncertainty are characterized and treated. This is primarily because the level 2 PSA deals with complex phenomenological processes that are deterministic in nature rather than random processes, and there are no probabilistic models characterizing them clearly. As a result, the probabilistic quantification of the level 2 PSA is often subjected to two sources of uncertainty: (a) incomplete modeling of accident pathways or different predictions for the behavior of phenomenological events and (b) expert-to-expert variation in estimating the occurrence probability of phenomenological events. While a clear definition of the two sources of uncertainty involved in the level 2 PSA makes it possible to treat an uncertainty in a consistent manner, careless application of these different sources of uncertainty may produce different conclusions in the decision-making process. The primary purpose of this paper is to characterize typical sources of uncertainty that would often be addressed in the level 2 PSA and their impacts on the PSA level 2 risk results. An additional purpose of this paper is to give a formal approach on how to combine random uncertainties addressed in the level 1 PSA with subjectivistic uncertainties addressed in the level 2 PSA

  16. A formal guidance for handling different uncertainty sources employed in the level 2 PSA

    International Nuclear Information System (INIS)

    Ahn, Kwang Il; Yang, Joon Eon; Ha, Jae Joo

    2004-01-01

    The methodological framework of the level 2 PSA appears to be currently standardized in a formalized fashion, but there have been different opinions on the way the sources of uncertainty are characterized and treated. This is primarily because the level 2 PSA deals with complex phenomenological processes that are deterministic in nature rather than random processes, and there are no probabilistic models characterizing them clearly. As a result, the probabilistic quantification of the level 2 PSA CET/APET is often subjected to two sources of uncertainty: (a) incomplete modeling of accident pathways or different predictions for the behavior of phenomenological events and (b) expert-to-expert variation in estimating the occurrence probability of phenomenological events. While a clear definition of the two sources of uncertainty involved in the level 2 PSA makes it possible to treat an uncertainty in a consistent manner, careless application of these different sources of uncertainty may produce different conclusions in the decision-making process. The primary purpose of this paper is to characterize typical sources of uncertainty that would often be addressed in the level 2 PSA and to provide a formal guidance for quantifying their impacts on the PSA level 2 risk results. An additional purpose of this paper is to give a formal approach on how to combine random uncertainties addressed in the level 1 PSA with subjectivistic uncertainties addressed in the level 2 PSA

  17. Benchmark exercises on PWR level-1 PSA (step 3). Analyses of accident sequence and conclusions

    International Nuclear Information System (INIS)

    Niwa, Yuji; Takahashi, Hideaki.

    1996-01-01

    The results of level 1 PSA generate fluctuations due to the assumptions based on several engineering judgements set in the stages of PSA analysis. On the purpose of the investigation of uncertainties due to assumptions, three kinds of a standard problem, what we call benchmark exercise have been set. In this report, sensitivity studies (benchmark exercise) of sequence analyses are treated and conclusions are mentioned. The treatment of inter-system dependency would generate uncertainly of PSA. In addition, as a conclusion of the PSA benchmark exercise, several findings in the sequence analysis together with previous benchmark analyses in earlier INSS Journals are treated. (author)

  18. Prebiopsy biparametric MRI: differences of PI-RADS version 2 in patients with different PSA levels.

    Science.gov (United States)

    Choi, M H; Lee, Y J; Jung, S E; Rha, S E; Byun, J Y

    2018-06-09

    To validate the diagnostic accuracy of Prostate Imaging-Reporting and Data System (PI-RADS) version 2 in detecting clinically significant prostate cancer (csPCa, Gleason score ≥7) on prebiopsy biparametric MRI (bpMRI) in patients with different prostate-specific antigen (PSA) levels. This retrospective study included 184 patients who underwent prebiopsy bpMRI followed by transrectal ultrasonography-guided biopsy between June 2015 and February 2017. Reader 1 performed a combination of systematic and targeted biopsy with cognitive fusion after reviewing bpMRI and reader 2 reviewed the bpMRIs retrospectively. PI-RADS categories 4 and 5 were considered positive, and the results of the biopsy were considered the reference standard. Diagnostic performance of PI-RADS of bpMRI was evaluated in two PSA groups with a PSA cut-off level of 10 ng/ml and compared to PSA and the PSA density using receiver operating characteristics (ROC) curve analysis. csPCa was diagnosed in 24 of 123 patients (19.5%) and 26 of 61 patients (42.6%) in the low and high PSA groups, respectively. A PI-RADS v2 category by either readers 1 or 2 had a significantly better performance to detect csPCa than PSA in both PSA groups. In the high PSA group, only one csPCa was missed by reader 2, but none by reader 1. In the low PSA group, readers 1 and 2 were unable to detect seven and five of the 24 csPCas, respectively. Prebiopsy bpMRI has good performance for detecting csPCa in the high PSA group but may miss small-volume csPCa in the low PSA group. Copyright © 2018 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  19. Correlation between bone scan findings and serum PSA level in prostate cancer patients in Bangladesh: both newly diagnosed and hormonally treated cases

    International Nuclear Information System (INIS)

    Yasmeen, S.; Nasreen, F.; Kabir, M.F.

    2007-01-01

    Full text: The objective of the current study was to determine whether pre- treatment serum prostate specific antigen (PSA) levels can identify a group with low probability of osseous metastases and safely eliminate the need for bone scan as a routine part of the staging evaluation in Bangladeshi patients with newly diagnosed prostate carcinoma. Also, to find out a cut off value for serum PSA level for predicting positive bone scan in newly diagnosed Bangladeshi prostate cancer patients and to assess the role of PSA level in hormonally treated cases. Prostate cancer most commonly metastasizes to the bone. Bone scintigraphy is one of the best methods in detecting bone metastases, assessing the progression of the disease and response to therapy. For more than 30 yrs it has been known that bone scintigraphy is more sensitive than radiographic, clinical evaluation or chemical markers such as alkaline phosphatase or acid phosphatase in detection of early osseous metastatic prostate cancer. The introduction of PSA has dramatically changed the management of prostate cancer. Serum PSA level has proven to be a useful serum marker for detection of metastatic prostate cancer and it provides the best overall correlation. It also has considerable impact on bone scanning. Of special significance is the fact that patients who have a low PSA level in previously untreated carcinoma of prostate are extremely unlikely to have positive findings on a bone scan for metastases. The picture is different in patients who has received and responded to hormonal therapy. Bone scintigraphy appears to be extremely useful in patients whose PSA level begins to rise after surgical procedure. Patients, who were on anti- androgen therapy, even though they had visible metastatic disease on bone scans, had normal level of PSA Patients and methods: A total of 390 cases were studied. Some (n=242) were newly diagnosed without having any specific treatment other than surgery. Others (n=148) were old cases

  20. Development of the SKI Handbook for reviewing PSA after the review of the of a PSA level 2 study

    International Nuclear Information System (INIS)

    Lindholm, Ilona; Sairanen, Risto

    2003-02-01

    A review of the Oskarshamn 2 Level 2 PSA has been conducted by VTT Processes. One objective of the review was validation and development of Tillsynshandbok PSA applying it to Oskarshamn 2 PSA Level 2 study. The review was based on the PSA Level 2 documentation: the main report, the supporting reports on containment success criteria and release calculations with the MAAP4 code, and five phenomenological reports for selected specific questions. The main result of the phenomenological analyses is that none of the phenomena considered contributes to the conditional failure probability of the Oskarshamn 2 containment in severe accidents. The project was conducted as a set of separate studies and the project quality assurance has also focused on one part at the time. As such, the quality assurance is adequate. A high level QA ensuring that all separate studies and analysis steps use same assumptions seems to be missing. Results from the phenomenology reports are not always transferred to accident analyses and vice versa. There is no specific discussion of uncertainty or sensitivity analyses. In general, the number of sensitivity analyses could be larger. Such should have been provided for sequences or phenomena that could result in early or unmitigated release. Examples are pressure vessel failure at high pressure, the effect of larger hydrogen production, and the key assumptions used for steam explosion and direct containment heating. Suggestions for additional sensitivity studies have been given in discussion of phenomenological reports. The project documentation is generally good. Missing information is usually associated with transfer of results from one study to another. It can be assumed that the information exists also in this cases but has not been documented in the reports above. Documentation of the containment event trees and the assumptions used for them could be more detailed, maybe similar to the approach used in the Appendix of this report. More effort

  1. Approach to development and use of PSA Level 2 analysis for the Cernavoda nuclear power plant

    International Nuclear Information System (INIS)

    Turcu, I.; Deaconu, R.; Radu, G.

    1998-01-01

    This paper first describes the status of PSA activities for the Cernavoda NPP and the extension of the PSA work to include Level 2 PSA. Important characteristics of this reactor type for Level 2 PSA are outlined. Due to the specific layout of the CANDU reactor the evolution of severe accidents is considerably different to vessel type LWRs. Accidents can be roughly categorized into three categories, ''''severe accidents'''' which lead to the loss of core structural integrity, delayed loss of core structural integrity as a consequence of the loss of heat sinks, and fuel channel failures. The current work for modelling accident progression in the core region is described. The elements for the Level 2 PSA including definition of PDSs, probabilistic containment logic and source term calculation are outlined. It is pointed out that uncertainties have to be considered which are contained in the models to bridge knowledge gaps. For this purpose sensitivity studies will be carried out for key modelling assumptions. (author)

  2. Review process of PSA level 2 of KBR - Concept and Experience

    International Nuclear Information System (INIS)

    Andernacht, M.; Glaser, H.; Sonnenkalb, M.

    2013-01-01

    In Germany, a periodic safety review (PSR) has to be performed every ten years by the utility. In the past, a PSR only included a plant-specific probabilistic safety analysis (PSA) Level 1 study. Since a revised version of the German PSA guideline has been released in 2005, these plant-specific PSAs have to include a PSA Level 2, too. For the NPP Brokdorf (KBR) PSA Level 2 project, an agreement was reached between all parties involved that the study will be performed not as a part of the PSR process, but supplementary to it. This paper will focus on conclusions and findings from an ongoing parallel review process of the first full scope PSA Level 2 performed by the utility for KBR, a typical German PWR-1300. The responsible authority 'Ministerium fuer Soziales, Gesundheit, Familie, Jugend und Senioren des Landes Schleswig- Holstein' (MSGF) initiated this parallel review process in agreement with the utility KBR and the E.ON Kernkraft in 2006. The project will be completed soon. Such a review process allows that essential steps of the PSA will be reviewed and commented before the PSA Level 2 will be finished. So the benefit from this parallel review process is a significant enhancement of the quality and completeness of the PSA Level 2 study as the majority of the recommendations given by the review team has been taken over by the utility and the developer of the PSA, the AREVA NP company. Further, a common understanding and agreement will be reached at the end between all parties involved on the major topics of the PSA Level 2 study. The paper is followed by the slides of the presentation. (authors)

  3. Review process of PSA Level 2 of KBR. Concept and experience

    International Nuclear Information System (INIS)

    Andernacht, Martin; Glaser, Hendrik; Sonnenkalb, Martin

    2009-01-01

    In Germany, a periodic safety review (PSR) has to be performed every 10 years by the utility. In the past, a PSR only included a plant-specific probabilistic safety analysis (PSA) Level 1 study. For the NPP Brokdorf (KBR) PSA Level 2 project, an agreement was reached between all parties involved that the study will be performed not as a part of the PSR process, but supplementary to it. Since a revised version of the German PSA guideline has been released in 2005, these plant-specific PSAs have to include a PSA Level 2, too. This paper will focus on conclusions and findings from a ongoing parallel review process of the first full scope PSA Level 2 performed by the utility for KBR, a typical German PWR-1300. The responsible authority 'Ministerium fuer Soziales, Gesundheit, Familie, Jugend und Senioren des Landes Schleswig-Holstein (MSGF)' (Ministry of Social Affairs, Health, Family, Youth and Senior Citizens of Schleswig-Holstein) initiated this parallel review process in agreement with the utility KBR and the E.ON Kernkraft in 2006. The project will be completed soon. Such a review process allows that essential steps of the PSA will be reviewed and commented before the PSA Level 2 will be finished. So the benefit from this parallel review process is a significant enhancement of the quality and completeness of the PSA Level 2 study as the majority of the recommendations given by the review team has been taken over by the utility and the developer of the PSA, the Areva NP company. Further, a common understanding and agreement will be reached at the end between all parties involved on the major topics of the PSA Level 2 study. (orig.)

  4. Comparative Study on Atmospheric Dispersion Module of Level 3 PSA

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, Dahye; Jang, Misuk; Kang, Hyun Sik; Kim, Seoung Rae [NESS, Daejeon (Korea, Republic of)

    2016-10-15

    Some regulation documents such as Regulatory Guides and NUREG publications from the U.S. Nuclear Regulatory Commission (NRC) have influences on domestic radiation environmental analyses. As renewal versions of NUREG-0800 and NUREG-1555 have issued lately, the assessment for Severe Accident (SA) with Probabilistic Safety Assessment (PSA) should be added to Safety Analysis Report (SAR) and Radiation Environmental Report (RER). Because these reports are the required documents for obtaining the construction permit and operating license, it is important to understand the PSA methodology and it needs to improve the site-specific input data of L3PSA codes for SA. First, our review focuses on the atmospheric dispersion and deposition related input data of L3PSA code in this paper. Then we will continue to review the improvements of other input data. Two atmospheric dispersion models, which are PAVAN developed for design basis accident and ATMOS of MACCS2 code developed for SA, were reviewed in this paper. L3PSA deals with the effects of severe accidents and basically includes the evaluation of both short- and long-term effects. Therefore, both the deposition effects and nuclide information(type, amount, and chemical characteristics of released radionuclide) would be considered as the input parameters of atmospheric dispersion model for L3PSA. Additionally, the meteorological data would be sampled randomly to meet the purpose of probabilistic method. However, the sampling method would be selected according to analysis purpose. After review, ATMOS module and its input data are suitably developed for the atmospheric dispersion analysis of L3PSA. However, ATMOS module was developed using the site-specific terrain and environment characteristics. For the domestic application, it needs to study the input data reflecting the Korean terrain and environment characteristics. It would be also continuously improved in response to the time- and site-specific changes of weather

  5. Level 1 PSA study of Mochovce unit 1 NPP (SM AA 10 and 08)

    International Nuclear Information System (INIS)

    Cillik, I.

    1997-01-01

    This paper presents genesis of Level 1 PSA project preparation for all operational modes of Mochovce NPP unit 1 including the description of its' main objectives, scope and working method. The PSA study which includes full power (FPSA) as well as shutdown and low power conditions (SPSA) Level 1 PSA has to support the nuclear safety improvements of the unit. They evaluate the basic design and the benefits of all improvements, which were found necessary to be incorporated before the start-up of the unit. The study includes internal events (transients and under-loss of coolant accident, LOCAs), internal hazards as fires and floods and selected external hazards as earthquake, influence of external industry, extreme meteorological conditions and aircraft crash.The PSA (both FPSA and SPSA) models is developed using the RISK SPECTRUM PSA code. (author)

  6. Methodologies for uncertainty analysis in the level 2 PSA and their implementation procedures

    International Nuclear Information System (INIS)

    Ahn, Kwang Il; Yang, Joon Eun; Kim, Dong Ha

    2002-04-01

    Main purpose of this report to present standardized methodologies for uncertainty analysis in the Level 2 Probabilistic Safety Assessment (PSA) and their implementation procedures, based on results obtained through a critical review of the existing methodologies for the analysis of uncertainties employed in the Level 2 PSA, especially Accident Progression Event Tree (APET). Uncertainties employed in the Level 2 PSA, quantitative expressions of overall knowledge of analysts' and experts' participating in the probabilistic quantification process of phenomenological accident progressions ranging from core melt to containment failure, their numerical values are directly related to the degree of confidence that the analyst has that a given phenomenological event or accident process will or will not occur, or analyst's subjective probabilities of occurrence. These results that are obtained from Level 2 PSA uncertainty analysis, become an essential contributor to the plant risk, in addition to the Level 1 PSA and Level 3 PSA uncertainties. Uncertainty analysis methodologies and their implementation procedures presented in this report was prepared based on the following criteria: 'uncertainty quantification process must be logical, scrutable, complete, consistent and in an appropriate level of detail, as mandated by the Level 2 PSA objectives'. For the aforementioned purpose, this report deals mainly with (1) summary of general or Level 2 PSA specific uncertainty analysis methodologies, (2) selection of phenomenological branch events for uncertainty analysis in the APET, methodology for quantification of APET uncertainty inputs and its implementation procedure, (3) statistical propagation of uncertainty inputs through APET and its implementation procedure, and (4) formal procedure for quantification of APET uncertainties and source term categories (STCs) through the Level 2 PSA quantification codes

  7. Treatment of the loss of ultimate heat sink initiating events in the IRSN level 1 PSA

    International Nuclear Information System (INIS)

    Dupuy, Patricia; Georgescu, Gabriel; Corenwinder, Francois

    2014-01-01

    The total loss of the ultimate heat sink is an initiating event which, even it is mainly of external origin, has been considered in the frame of internal events Level 1 PSA by IRSN. The on-going actions on the development of external hazards PSA and the recent incident of loss of the heat sink induced by the ingress of vegetable matter that occurred in France in 2009 have pointed out the need to improve the modeling of the loss of the heat sink initiating event and sequences to better take into account the fact that this loss may be induced by external hazards and thus affect all the site units. The paper presents the historical steps of the modeling of the total loss of the heat sink, the safety stakes of this modeling, the main assumptions used by IRSN in the associated PSA for the 900 MWe reactors and the results obtained. The total loss of the heat sink was not initially addressed in the safety demonstration of French NPPs. On the basis of the insights of the first probabilistic assessments performed in the 80's, the risks associated to this 'multiple failure situation' turned out to be very significant and design and organisational improvements were implemented on the plants. Reviews of the characterization of external hazards and of their consequences on the installations and French operating feedback have revealed that extreme hazards may induce a total loss of the heat sink. Moreover, the accident that occurred at Fukushima in 2011 has pointed out the risk of such a loss of long duration at all site units in case of extreme hazards. In this context, it seems relevant to further improve the modelling of the total loss of the heat sink by considering the external hazards that may cause this loss. In a first step, IRSN has improved the assumptions and data used in the loss of the heat sink PSA model, in particular by considering that such a loss may affect all the site units. The next challenge will be the deeper analysis of the impact of external hazards on

  8. Improvement of Level-1 PSA computer code package -A study for nuclear safety improvement-

    International Nuclear Information System (INIS)

    Park, Chang Kyu; Kim, Tae Woon; Ha, Jae Joo; Han, Sang Hoon; Cho, Yeong Kyun; Jeong, Won Dae; Jang, Seung Cheol; Choi, Young; Seong, Tae Yong; Kang, Dae Il; Hwang, Mi Jeong; Choi, Seon Yeong; An, Kwang Il

    1994-07-01

    This year is the second year of the Government-sponsored Mid- and Long-Term Nuclear Power Technology Development Project. The scope of this subproject titled on 'The Improvement of Level-1 PSA Computer Codes' is divided into three main activities : (1) Methodology development on the under-developed fields such as risk assessment technology for plant shutdown and external events, (2) Computer code package development for Level-1 PSA, (3) Applications of new technologies to reactor safety assessment. At first, in the area of PSA methodology development, foreign PSA reports on shutdown and external events have been reviewed and various PSA methodologies have been compared. Level-1 PSA code KIRAP and CCF analysis code COCOA are converted from KOS to Windows. Human reliability database has been also established in this year. In the area of new technology applications, fuzzy set theory and entropy theory are used to estimate component life and to develop a new measure of uncertainty importance. Finally, in the field of application study of PSA technique to reactor regulation, a strategic study to develop a dynamic risk management tool PEPSI and the determination of inspection and test priority of motor operated valves based on risk importance worths have been studied. (Author)

  9. Impact of PSA density of transition zone as a potential parameter in reducing the number of unnecessary prostate biopsies in patients with psa levels between 2.6 and 10.0 ng/mL.

    Science.gov (United States)

    Castro, Hugo A Socrates; Iared, Wagner; Santos, José Eduardo Mourão; Solha, Raphael Sandes; Shigueoka, David Carlos; Ajzen, Sergio Aron

    2018-04-10

    To assess the accuracy of prostate-specific antigen (PSA) adjusted for the transition zone volume (PSATZ) in predicting prostate cancer by comparing the ability of several PSA parameters in predicting prostate cancer in men with intermediate PSA levels of 2.6 - 10.0 ng/mL and its ability to reduce unnecessary biopsies. This study included 656 patients referred for prostate biopsy who had a serum PSA of 2.6 - 10.0 ng/mL. Total prostate and transition zone volumes were measured by transrectal ultrasound using the prolate ellipsoid method. The clinical values of PSA, free-to-total (F/T) ratio, PSA density (PSAD) and PSATZ for the detection of prostate cancer were calculated and statistical comparisons between biopsy-positive (cancer) and biopsy-negative (benign) were conducted. Cancer was detected in 172 patients (26.2%). Mean PSA, PSATZ, PSAD and F/T ratio were 7.5 ng/mL, 0.68 ng/mL/cc. 0.25 ng/mL/cc and 0.14 in patients with prostate cancer and 6.29 ng/mL, 0.30 ng/mL/cc, 0.16 ng/mL/cc and 0.22 in patients with benign biopsies, respectively. ROC curves analysis demonstrated that PSATZ had a higher area under curve (0,838) than F/T ratio (0,806) (PPSA. Compared to other PSA related parameters, it was better in differentiating between prostate cancer and benign prostatic enlargement. Also, PSATZ could reduce a significant number of unnecessary biopsies. Copyright® by the International Brazilian Journal of Urology.

  10. Treatment strategy for metastatic prostate cancer with extremely high PSA level: reconsidering the value of vintage therapy.

    Science.gov (United States)

    Yamada, Yasutaka; Sakamoto, Shinichi; Amiya, Yoshiyasu; Sasaki, Makoto; Shima, Takayuki; Komiya, Akira; Suzuki, Noriyuki; Akakura, Koichiro; Ichikawa, Tomohiko; Nakatsu, Hiroomi

    2018-05-04

    The prognostic significance of initial prostate-specific antigen (PSA) level for metastatic prostate cancer remains uncertain. We investigated the differences in prognosis and response to hormonal therapies of metastatic prostate cancer patients according to initial PSA levels. We analyzed 184 patients diagnosed with metastatic prostate cancer and divided them into three PSA level groups as follows: low (PSA progression-free survival (PFS) for first-line ADT and overall survival (OS) within each of the three groups. Furthermore, we analyzed response to antiandrogen withdrawal (AW) and alternative antiandrogen (AA) therapies after development of castration-resistant prostate cancer (CRPC). No significant differences in OS were observed among the three groups (P = 0.654). Patients with high PSA levels had significantly short PFS for first-line ADT (P = 0.037). Conversely, patients in the high PSA level group had significantly longer PFS when treated with AW than those in the low PSA level group (P = 0.047). Furthermore, patients with high PSA levels had significantly longer PFS when provided with AA therapy (P = 0.049). PSA responders to AW and AA therapies had significantly longer survival after CRPC development than nonresponders (P = 0.011 and P PSA level predicted favorable response to vintage sequential ADT and AW. The current data suggest a novel aspect of extremely high PSA value as a favorable prognostic marker after development of CRPC.

  11. Development of the SKI Handbook for reviewing PSA after the review of the of a PSA level 2 study; Utveckling av SKIs Tillsynshandbok foer PSA utifraan granskningen av en PSA Nivaa-2 studie

    Energy Technology Data Exchange (ETDEWEB)

    Lindholm, Ilona; Sairanen, Risto [VTT Processes, Helsinki (Finland)

    2003-02-01

    A review of the Oskarshamn 2 Level 2 PSA has been conducted by VTT Processes. One objective of the review was validation and development of Tillsynshandbok PSA applying it to Oskarshamn 2 PSA Level 2 study. The review was based on the PSA Level 2 documentation: the main report, the supporting reports on containment success criteria and release calculations with the MAAP4 code, and five phenomenological reports for selected specific questions. The main result of the phenomenological analyses is that none of the phenomena considered contributes to the conditional failure probability of the Oskarshamn 2 containment in severe accidents. The project was conducted as a set of separate studies and the project quality assurance has also focused on one part at the time. As such, the quality assurance is adequate. A high level QA ensuring that all separate studies and analysis steps use same assumptions seems to be missing. Results from the phenomenology reports are not always transferred to accident analyses and vice versa. There is no specific discussion of uncertainty or sensitivity analyses. In general, the number of sensitivity analyses could be larger. Such should have been provided for sequences or phenomena that could result in early or unmitigated release. Examples are pressure vessel failure at high pressure, the effect of larger hydrogen production, and the key assumptions used for steam explosion and direct containment heating. Suggestions for additional sensitivity studies have been given in discussion of phenomenological reports. The project documentation is generally good. Missing information is usually associated with transfer of results from one study to another. It can be assumed that the information exists also in this cases but has not been documented in the reports above. Documentation of the containment event trees and the assumptions used for them could be more detailed, maybe similar to the approach used in the Appendix of this report. More effort

  12. Level-1 PSA to support the design of the KALIMER-600 Sodium Cooled Fast Reactor

    International Nuclear Information System (INIS)

    Han, Sang Hoon; Kim, Tae-Woon; Jeong, Hae-Yong; Han, Seok Joong; Ahn, Kwang-Il; Yang, Joon-Eon

    2012-01-01

    A sodium-cooled fast reactor, KALIMER-600, is under development. Its fuel is the metal fuel of U-TRU-Zr and it uses sodium as a coolant. KALIMER-600 has passive safety features such as passive shutdown functions, passive pump coast-down features, and passive decay heat removal systems. It has inherent reactivity feedback effects. The probabilistic safety assessment (PSA) will be one of the initiating subjects for designing KALIMER-600 from the aspects of risk informed design. A preliminary level-1 internal full power PSA has been performed to evaluate the safety level and its applicability for the KALIMER-600 conceptual design. Various design alternatives are evaluated from the viewpoint of PSA in order to support the design of the KALIMER-600. Sensitivity studies are also performed to evaluate the assumptions made for the PSA. The applicability and weakness of the KALIMER-600 PSA are discussed. The technical issues to be solved in performing the PSA will be discussed. (authors)

  13. Establishment of Infrastructure for Domestic-Specific Level 3 PSA based on MACCS2

    Energy Technology Data Exchange (ETDEWEB)

    Jang, Seung-Cheol; Han, Seok-Jung; Choi, Sun-Yeong; Lee, Seung-Jun [KAERI, Daejeon (Korea, Republic of); Kim, Wan-Seob [Korea Reliability Technology and System, Daejeon (Korea, Republic of)

    2015-05-15

    Research activities related to the Level 3 PSA have naturally disappeared since the use of risk surrogates. Recently, Level 3 PSA was only performed to the extent of the purpose of operating license for the plant under construction. Since the Fukushima accident, concern about a comprehensive site-specific Level 3 PSA has been raised for some compelling reasons, especially the evaluation of the domestic multi-unit site risk effect including other site radiological sources (e.g., spent fuel pool, multi-units). Unfortunately, there are no domestic-specific consequence analysis code and input database required to perform a site-specific Level 3 PSA. The paper focuses on the development of the input data management system for domestic-specific Level 3 PSA based MACCS2 (MELCOR Accident Consequence Code System). The authors call it KOSCA-MACCS2 (Korea Off-Site Consequence Analysis based in MACCS2). It serves as an integrated platform for a domestic-specific Level 3 PSA. Also, it provides the pre-processing modules to automatically generate MACCS2 input from diverse types of the domestic-specific data including numerical map data, e.g., meteorological data, numerical population map, digital land use map, economic statistics and so on. Note that some functions should be still developed and added on it, e.g., post-processing module to convert MACCS2 outputs to graphic report forms, and so on. Henceforth, it is necessary to develop a Korean-specific Level 3 PSA code as a substitution for the foreign software, MACCS2.

  14. PSA results for Hanford high level waste Tank 101-SY

    Energy Technology Data Exchange (ETDEWEB)

    MacFarlane, D.R.; Bott, T.F.; Brown, L.F.; Stack, D.W. [Los Alamos National Lab., NM (United States); Kindinger, J.; Deremer, R.K.; Medhekar, S.R.; Mikschl, T.J. [PLG, Inc., Newport Beach, CA (United States)

    1993-10-01

    Los Alamos National Laboratory has performed a comprehensive probabilistic safety assessment (PSA) that includes consideration of external events for the weapons-production wastes stored in tank number 241-SY-101, commonly known as Tank 101-SY, as configured in December 1992. This tank, which periodically releases (``burps``) a gaseous mixture of hydrogen, nitrous oxide, ammonia, and nitrogen, was analyzed because of public safety concerns associated with the potential for release of radioactive tank contents should this gas mixture be ignited during one of the burps. In an effort to mitigate the burping phenomenon, an experiment is underway in which a large pump has been inserted into the tank to determine if pump-induced circulation of the tank contents will promote a slow, controlled release of the gases. This PSA for Tank 101-SY, which did not consider the pump experiment or future tank-remediation activities, involved three distinct tasks. First, the accident sequence analysis identified and quantified those potential accidents whose consequences result in tank material release. Second, characteristics and release paths for the airborne and liquid radioactive source terms were determined. Finally, the consequences, primarily onsite and offsite potential health effects resulting from radionuclide release, were estimated, and overall risk curves were constructed. An overview of each of these tasks and a summary of the overall results of the analysis are presented in the following sections.

  15. PSA results for Hanford high level waste Tank 101-SY

    International Nuclear Information System (INIS)

    MacFarlane, D.R.; Bott, T.F.; Brown, L.F.; Stack, D.W.; Kindinger, J.; Deremer, R.K.; Medhekar, S.R.; Mikschl, T.J.

    1993-01-01

    Los Alamos National Laboratory has performed a comprehensive probabilistic safety assessment (PSA) that includes consideration of external events for the weapons-production wastes stored in tank number 241-SY-101, commonly known as Tank 101-SY, as configured in December 1992. This tank, which periodically releases (''burps'') a gaseous mixture of hydrogen, nitrous oxide, ammonia, and nitrogen, was analyzed because of public safety concerns associated with the potential for release of radioactive tank contents should this gas mixture be ignited during one of the burps. In an effort to mitigate the burping phenomenon, an experiment is underway in which a large pump has been inserted into the tank to determine if pump-induced circulation of the tank contents will promote a slow, controlled release of the gases. This PSA for Tank 101-SY, which did not consider the pump experiment or future tank-remediation activities, involved three distinct tasks. First, the accident sequence analysis identified and quantified those potential accidents whose consequences result in tank material release. Second, characteristics and release paths for the airborne and liquid radioactive source terms were determined. Finally, the consequences, primarily onsite and offsite potential health effects resulting from radionuclide release, were estimated, and overall risk curves were constructed. An overview of each of these tasks and a summary of the overall results of the analysis are presented in the following sections

  16. The impact of hypoxemia on serum total and free prostate-specific antigen levels in patients with chronic obstructive pulmonary disease.

    Science.gov (United States)

    Ozge, Cengiz; Bozlu, Murat; Ozgur, Eylem Sercan; Tek, Mesut; Tunckiran, Ahmet; Muslu, Necati; Ilvan, Ahmet

    2015-05-01

    Prostate-specific antigen (PSA) is the most important biochemical marker in the diagnosis and follow-up of patients with prostate cancer. In recent years, a relationship between PSA levels and hypoxic conditions has been described. However, no study has investigated the PSA levels in patients with chronic obstructive pulmonary disease (COPD). The aim of the present study was to investigate the impact of hypoxemia on serum total (tPSA) and free PSA (fPSA) levels in patients with COPD. Between January 2010 and January 2014, 95 male patients who hospitalized for acute exacerbations of COPD and 80 control subjects were enrolled in the study. Serum tPSA and fPSA levels and f/tPSA ratios were determined in all patients on the first day of hospitalization (exacerbation) and 7 days after the treatment (stable state). Statistical analysis included paired t test and Mann-Whitney U test. No statistically significant differences were found between COPD and control groups with regard to the baseline characteristics, except for smoking status. The levels of serum tPSA and fPSA during exacerbation of COPD were significantly higher than the levels of the stable period (p 0.05). Hypoxemia during acute exacerbation of COPD can cause a rise in serum tPSA and fPSA levels, but f/tPSA ratio is not affected. Acute exacerbation of COPD may be added to list of the events in which PSA measurements must be interpreted with caution.

  17. Clinical performance of serum [-2]proPSA derivatives, %p2PSA and PHI, in the detection and management of prostate cancer.

    Science.gov (United States)

    Huang, Ya-Qiang; Sun, Tong; Zhong, Wei-De; Wu, Chin-Lee

    2014-01-01

    Prostate-specific antigen (PSA) has been widely used as a serum marker for prostate cancer (PCa) screening or progression monitoring, which dramatically increased rate of early detection while significantly reduced PCa-specific mortality. However, a number of limitations of PSA have been noticed. Low specificity of PSA may lead to overtreatment in men who presenting with a total PSA (tPSA) level of PHI) and %p2PSA, which were defined as [(p2PSA/fPSA) × √ tPSA] and [(p2PSA/fPSA) × 100] respectively, have been suggested to be increased in PCa and can better distinguish PCa from benign prostatic diseases than tPSA or fPSA. We performed a systematic review of the available scientific evidences to evaluate the potentials of %p2PSA and PHI in clinical application. Mounting evidences suggested that both %p2PSA and PHI possess higher area under the ROC curve (AUC) and better specificity at a high sensitivity for PCa detection when compare with tPSA and %fPSA. It indicated that measurements of %p2PSA and PHI significantly improved the accuracy of PCa detection and diminished unnecessary biopsies. Furthermore, elevations of %p2PSA and PHI are related to more aggressive diseases. %p2PSA and PHI might be helpful in reducing overtreatment on indolent cases or assessing the progression of PCa in men who undergo active surveillance. Further studies are needed before being applied in routine clinical practice.

  18. Research on the improvement of nuclear safety -Improvement of level 1 PSA computer code package-

    International Nuclear Information System (INIS)

    Park, Chang Kyoo; Kim, Tae Woon; Kim, Kil Yoo; Han, Sang Hoon; Jung, Won Dae; Jang, Seung Chul; Yang, Joon Un; Choi, Yung; Sung, Tae Yong; Son, Yung Suk; Park, Won Suk; Jung, Kwang Sub; Kang Dae Il; Park, Jin Heui; Hwang, Mi Jung; Hah, Jae Joo

    1995-07-01

    This year is the third year of the Government-sponsored mid- and long-term nuclear power technology development project. The scope of this sub project titled on 'The improvement of level-1 PSA computer codes' is divided into three main activities : (1) Methodology development on the underdeveloped fields such as risk assessment technology for plant shutdown and low power situations, (2) Computer code package development for level-1 PSA, (3) Applications of new technologies to reactor safety assessment. At first, in this area of shutdown risk assessment technology development, plant outage experiences of domestic plants are reviewed and plant operating states (POS) are decided. A sample core damage frequency is estimated for over draining event in RCS low water inventory i.e. mid-loop operation. Human reliability analysis and thermal hydraulic support analysis are identified to be needed to reduce uncertainty. Two design improvement alternatives are evaluated using PSA technique for mid-loop operation situation: one is use of containment spray system as backup of shutdown cooling system and the other is installation of two independent level indication system. Procedure change is identified more preferable option to hardware modification in the core damage frequency point of view. Next, level-1 PSA code KIRAP is converted to PC-windows environment. For the improvement of efficiency in performing PSA, the fast cutest generation algorithm and an analytical technique for handling logical loop in fault tree modeling are developed. 48 figs, 15 tabs, 59 refs. (Author)

  19. Research on the improvement of nuclear safety -Improvement of level 1 PSA computer code package-

    Energy Technology Data Exchange (ETDEWEB)

    Park, Chang Kyoo; Kim, Tae Woon; Kim, Kil Yoo; Han, Sang Hoon; Jung, Won Dae; Jang, Seung Chul; Yang, Joon Un; Choi, Yung; Sung, Tae Yong; Son, Yung Suk; Park, Won Suk; Jung, Kwang Sub; Kang Dae Il; Park, Jin Heui; Hwang, Mi Jung; Hah, Jae Joo [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1995-07-01

    This year is the third year of the Government-sponsored mid- and long-term nuclear power technology development project. The scope of this sub project titled on `The improvement of level-1 PSA computer codes` is divided into three main activities : (1) Methodology development on the underdeveloped fields such as risk assessment technology for plant shutdown and low power situations, (2) Computer code package development for level-1 PSA, (3) Applications of new technologies to reactor safety assessment. At first, in this area of shutdown risk assessment technology development, plant outage experiences of domestic plants are reviewed and plant operating states (POS) are decided. A sample core damage frequency is estimated for over draining event in RCS low water inventory i.e. mid-loop operation. Human reliability analysis and thermal hydraulic support analysis are identified to be needed to reduce uncertainty. Two design improvement alternatives are evaluated using PSA technique for mid-loop operation situation: one is use of containment spray system as backup of shutdown cooling system and the other is installation of two independent level indication system. Procedure change is identified more preferable option to hardware modification in the core damage frequency point of view. Next, level-1 PSA code KIRAP is converted to PC-windows environment. For the improvement of efficiency in performing PSA, the fast cutest generation algorithm and an analytical technique for handling logical loop in fault tree modeling are developed. 48 figs, 15 tabs, 59 refs. (Author).

  20. Final guidance document for extended Level 2 PSA Volume 1. Summary report for external hazards implementation in extended L2 PSA, validation of SAMG strategy and complement of ASAMPSA2 L2PSA guidance

    International Nuclear Information System (INIS)

    Loeffler, H.; Raimond, E.

    2016-01-01

    The present document is a summary of the deliverables produced within the ASAMPSA-E project for extended L2 PSA. These deliverables are: D30.7 vol. 2, 'Implementing external Events modelling in Level 2 PSA': D30.7 vol. 3: 'Verification and improvement of SAM strategy: D30.7 vol. 4: 'Consideration of shutdown states, spent fuel pools and recent R and D results'. Among many others, the following summary statements are provided: Analyses of external events: - No need for new methodology, - It is necessary to develop L1 PSA first and then clearly defined boundary conditions for the L2 PSA must be generated, - The remaining challenge is how to address adverse environmental conditions due to external hazards. Multi units: - No practical methodology exists to treat the problem, - A new methodology is necessary to be developed first for the L1 PSA. This should, from the beginning, take into account the specific needs of L2 PSA so that the boundary conditions for subsequent level 2 analysis can be generated adequately. SAM strategies verification and improvement: - L2 PSA methodology can usefully by applied and experience exists for internal initiating events L2 PSA, - How to address adverse environmental conditions due to external hazards - needs for new methodology or examples of experience, - How to model the decision process when there is a conflict of interest - needs for new methodology or examples of experience. For L2 PSA in shutdown states with open RPV, some new technical issues (fission product release, thermal load to structures above RPV) have to be addressed. Spent fuel pool issues have been developed, in particular: - Heat load from the melting spent fuel to structures above (e.g. to the containment roof) is a severe challenge for the plant and for the present-day, methodology is missing. Recent R and D achievements with relevance for L2 PSA: - Basic research has been continued in the radiochemistry (iodine and ruthenium chemistry) field, but the existing

  1. Clinical performance of serum [-2]proPSA derivatives, %p2PSA and PHI, in the detection and management of prostate cancer

    OpenAIRE

    Huang, Ya-Qiang; Sun, Tong; Zhong, Wei-De; Wu, Chin-Lee

    2014-01-01

    Prostate-specific antigen (PSA) has been widely used as a serum marker for prostate cancer (PCa) screening or progression monitoring, which dramatically increased rate of early detection while significantly reduced PCa-specific mortality. However, a number of limitations of PSA have been noticed. Low specificity of PSA may lead to overtreatment in men who presenting with a total PSA (tPSA) level of < 10 ng/mL. As a type of free PSA (fPSA), [-2]proPSA is differentially expressed in peripheral ...

  2. PSA Level 2 as element of an integral safety assessment before plant commissioning

    International Nuclear Information System (INIS)

    Loeffler, H.; Mildenberger, O.; Sonnenkalb, M.; Steinroetter, T.

    2012-01-01

    In Argentina the Central Nuclear Atucha II is near to completion. This is a pressurized heavy water reactor. PSA (Probability Safety Assessment) level 1, level 2 and level 3 have to be performed in order to show compliance with the Argentinean dose limit. Such studies have been done first by the former KWU in the 1980's to get the construction license (FABIAN 1985). Nowadays the plant owner NA-SA performs PSA level 1 and provides information about the core damage states to GRS, who does the subsequent PSA level 2 part. GRS delivers source terms to the environment and the associated frequencies to the Argentinean research institute CNEA, which performs level 3 together with NA-SA. Since GRS is situated in the middle of the chain, interface definition with both ends has been a significant task of the GRS activities. Experience gained during this process will be highlighted in the presentation. The analysis of PSA level 2 proper follows a traditional approach: -) deterministic accident simulation with integral code MELCOR; -) analyses of specific issues which are not covered by MELCOR; and -) probabilistic accident progression analysis with EVNTRE event tree methodology. It appears that MELCOR and EVNTRE and PSA guidelines in general are flexible enough to analyse new or uncommon reactor designs. It also appears that the plant specific design features may require analyses beyond present code capabilities, calling for expert judgment and they can largely determine PSA results. The behaviour of iodine is not yet covered satisfactorily by state-of-the-art models in MELCOR

  3. Application of PSA to Assess the Safety Level of Nuclear Power Plants

    International Nuclear Information System (INIS)

    Berg, H. P.; Goertz, R.

    2000-01-01

    This paper reviews the application of PSA in German nuclear power plant regulation. From a fundamental point of view, it has to be mentioned that as stipulated in the corresponding requirements, regulatory decision making in Germany is primarily based on deterministic analyses and evaluations. Therefore, PSA is not used as a stand alone but as a supplementary basis. In this context PSA has developed a valuable tool with continuously growing importance. Level 1+ PSAs are now elaborated for all German nuclear power plants in operation, most of them are already reviewed by the competent supervisory authority and its experts. Current research activities on the federal level primarily concentrate on the further development of the methodology in the areas human factor, common cause failures, accident management measures and reduction of uncertainties in methods and data. (author)

  4. Assessment of Atorvastatin Effectiveness on Serum PSA Level in Hypercholesterolemic Males

    Directory of Open Access Journals (Sweden)

    Darya Khosropanah

    2011-12-01

    Full Text Available The previous large retrospective studies demonstrated that treatment with Statins reduces both the incidence of prostate cancer by 50% and serum Prostate Specific Antigen (PSA level up to 40%. However the main problem in those studies was the absence of control groups of men with hypercholesterolemia without Statin treatment. We performed a small prospective controlled clinical trial to assess the influence of the treatment with Atorvastatin on serum PSA in men with hypercholesterolemia referred to our educational and treatment center from October 2007 to March 2008. In this study, among the newly diagnosed males with hypercholesterolemia (LDL > 130 mg/dl, 40 patients with LDL more than 190 mg/dl were selected as a case group and were treated with Atorvastatin (20 mg/day. Among the same population and in the same period, another 40 patients with LDL between 130 and 190 mg/dl were selected as first control group and were treated only with low fat diet. Another 40 patients with normal serum cholesterol and without any treatment were selected as second control group. The lipid profile and serum PSA level of patients of all groups were tested at the first and third months after the therapy. After completion of data, the mean serum lipids and PSA level were measured in both visits and compared with each other by paired t-test. Also the mean PSA change in two visits between three groups was compared by ANOVA and Tukey HSD test. There was not any significant difference in mean baseline PSA between hypercholesterolemic and normocholesterolemic patients (P=0.547. In case group, mean PSA and LDL was reduced by 14.1% (P=0.0001 and 30% (P=0.0001 respectively by second visit. In first control group, mean PSA was not changed significantly (P=0.337, whereas mean LDL in this group was reduced by 9.6% (P= 0.0001. Similarly in the second control group mean PSA was not changed significantly (P=0.309 by second visit. In addition, mean change of PSA in case group

  5. Application of PSA level 1 for the Fugen prototype ATR plant

    International Nuclear Information System (INIS)

    Ikeda, H.; Iguchi, Y.; Sotsu, M.; Seki, O.; Satou, S.

    1997-01-01

    This paper presents application of PSA Level-1 for Prototype Advanced Thermal Reactor Plant ''Fugen'' in consideration of the design characteristics of such reactor and verify the safety aspect of Fugen using thus established procedure, ATR resembles the boiling water reactor (BWR) in a number of points, but there are also some differences between the ATR and the BWR. Therefore. PSA procedure have been established by taking such difference into consideration and by referring to experience of PSA in USA and Japan. Moreover, the core damage frequency was calculated on Fugen by using thus established procedure. As a result, it was verified that results including the maximum value of the uncertainty estimation were found to be quite satisfactory against the target value of reactor damage frequency defined by the International Atomic Energy Agency (IAEA). (author)

  6. Main Aspects and Results of Level 2 PSA for KNPP WWER-1000/B320

    International Nuclear Information System (INIS)

    Mancheva, Kaliopa

    2014-01-01

    The PSA Level 2 for Kozloduy NPP (KNPP) is an update of an older study with wider scope of analysis. The older study represented the status of the units up to 2001. The current PSA Level 2 is based on the PSA Level 1 and represents the status of the units up to 2007 year concerning the systems and procedures included in PSA level 1 and status up to 2011 for the systems and procedures (e.g. SAMG) related to containment and severe accident aspects. The study is performed after the PSA level 1 has been finished and approved by the customer. Compare to the older analysis all modes of operation for analyzed in PSA level 1 event groups as well Spent Fuel Pool accidents are investigated. The analysis consists of both deterministic and probabilistic analysis. As part of deterministic analysis a contemporary containment strength analysis and accident progression deterministic analysis using last version of MELCOR are performed. The probabilistic analysis contains of two part: Interface PSA and CET are calculated using Riskspectrum program code. Two types of models for CET have been developed: one for conditional probabilities calculations and a set of simplified CET's for each PDS group-for integral model. The purpose of the first model is to be able to perform quick calculations and for sensitivity analyses as well. The simplified CET's are used for integral calculation of the model. Source Term analysis is mainly based on the MELCOR analyses results. All characteristics of the releases have been defined, i.e. location, mass, energy of radionuclide groups and activity of the released isotopes (most important are reported only). The main goals of the study are to analyze the status of the containment, systems designed to prevent containment failure and operator action required under the severe accident and to give quantitative assessment of the risk parameter LERF (Large Early Release Frequency). This report will present main aspects, results, finding and

  7. Elevated Serum PSA is Associated With Human Herpesvirus 8 Infection and Increased Circulating Cytokine Levels in Men From Tobago.

    Science.gov (United States)

    Henning, Jill D; Karamchandani, Jaideep M; Bonachea, Luis A; Bunker, Clareann H; Patrick, Alan L; Jenkins, Frank J

    2017-05-01

    Serum-prostate specific antigen (PSA) levels have been used for many years as a biomarker for prostate cancer. This usage is under scrutiny due to the fact that elevated PSA levels can be caused by other conditions such as benign prostatic hyperplasia and infections of or injury to the prostate. As a result, the identification of specific pathogens capable of increasing serum levels of PSA is important. A potential candidate responsible for elevated PSA is human herpesvirus 8 (HHV-8). We have reported previously that HHV-8 is capable of infecting and establishing a latent infection in the prostate. In this current study we test the hypothesis that HHV-8 infection is associated with elevated PSA levels. Circulating cytokine levels between men with elevated PSA and controls are also compared. HHV-8 serostatus was determined among men with elevated serum PSA (≥4 ng/ml; n = 168, no prostate cancer on biopsy) and age-matched controls (PSA PSA and 85 controls). Men with an elevated serum PSA were significantly more likely to be HHV-8 seropositive (42.9%) than the age-matched cancer-free men (22.2%; OR 2.51; 95%CI 1.48-4.29, P = 00001). Comparison of circulating cytokine levels between men with elevated serum PSA and controls indicated that elevated serum PSA is associated with a pro-inflammatory response with a mixed Th1/Th2 response while HHV-8 infection was associated with significantly higher levels of IL12p70, IL-10, and IL-13 indicating a Th2 immune response. We found a significant association between HHV-8 infection and increased levels of serum PSA. In an age of patient-centered medicine, men with an elevated serum PSA should be considered for HHV-8 serology testing to determine if HHV-8 is responsible for the elevated PSA. Prostate 77: 617-624, 2017. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  8. Post treatment PSA nadirs support continuing dose escalation study in patients with pretreatment PSA levels >10 ng/ml, but not in those with PSA <10 NG/ML

    International Nuclear Information System (INIS)

    Herold, D.H.; Hanlon, A.L.; Movsas, B.; Hanks, G.E.

    1996-01-01

    Purpose: We have recently shown that ICRU reporting point radiation doses above 71 Gy are not associated with improved bNED survival in prostate cancer patients with pretreatment PSA level 20 ng/ml we found a strong correlation between dose and nadir values < 1.0 ng/ml (p=.003) as well as for nadir's < 0.5 ng/ml (p=.04). This dose/nadir effect held at several dose levels, but 74 Gy for nadir values < 1.0 ng/ml and 72 Gy for nadir's < 0.5 ng/ml remained the most significant. 32% of these patients achieved a nadir < 1.0ng/ml and 15% < 0.5ng/ml. Conclusions: This analysis provides strong additional support that patients with pretreatment PSA values of < 10 ng/ml do not benefit from dose escalation beyond an ICRU reporting point dose of 71 Gy. For patients with pretreatment PSA's of 10-19.9 ng/ml there is no dose/nadir response evaluated at a nadir of 1.0 ng/ml; however, there is a borderline effect observed at a nadir of 0.5 ng/ml. Patients with pretreatment PSA's of 20 ng/ml or greater clearly benefit from higher doses as evaluated by PSA nadirs of 1.0 ng/ml, and 0.5 ng/ml. These studies support the continued investigation of dose escalation in treating patients with PSA levels over 10 ng/ml, they do not support continued investigation of dose escalation beyond 71 Gy in patients with pretreatment PSA levels < 10 ng/ml. The failure to demonstrate any dose response for the low PSA group and the finding of only a borderline effect for the intermediate PSA group may be influenced by the relatively small number of patients in our series treated to doses < 70 Gy and the fact that none of our patients were treated to doses below 65.98 Gy. The lower limit of acceptible dose has yet to be defined

  9. ASAMPSA-E guidance for level 2 PSA Volume 3. Verification and improvement of SAM strategies with L2 PSA

    International Nuclear Information System (INIS)

    Rahni, N.; Raimond, E.; Jan, P.; Lopez, J.; Loeffler, H.; Mildenberger, O.; Kubicek, J.; Vitazkova, J.; Ivanov, I.; Groudev, P.; Lajtha, G.; Serrano, C.; Zhabin, O.; Prosek, Andrej; Dirksen, G.; Yu, S.; Oury, L.; Hultqvist, G.

    2016-01-01

    For each NPP, severe accident management (SAM) strategies shall make use of components or systems and human resources to limit as far as possible the consequences of any severe accident on-site and off-site. L2 PSA is one of the tools that can be used to verify and improve these strategies. The present report (deliverable D40.5 of the project ASAMPSA-E) provides an opportunity for a comparison of objectives in the different countries in terms of SAM strategies verification and improvement. The report summarizes also experience of each partner (including potential deficiencies) involved in this activity, in order to derive some good practices and required progress, addressing: - SAM modeling in L2 PSA, - Positive and negative aspects in current SAM practices, - Discussion on possible criteria related to L2 PSA for verification and improvement: risk reduction (in relation with WP30 activities on risk metrics), reduction of uncertainties on the severe accident progression paths until NPP stabilization, reduction of human failure conditional probabilities (depending on the SAM strategy, the environmental conditions...), - Review with a perspective of verification and improvement of the main SAM strategies (corium cooling, RCS depressurization, control of flammable gases, reactivity control, containment function, containment pressure control, limitation of radioactive releases,...), - SAM strategies to be considered in the context of an extended L2 PSA (as far possible, depending on existing experience), taking into account all operating modes, accidents also occurring in the SFPs and long term and multi-unit accidents. The deliverable D40.5 is developed from the partners' experience. Many of the topics described here are beyond the common practices of L2 PSA applications: in some countries, L2 PSA application is limited to the calculations of frequencies of release categories with no formal requirement for SAM verification and improvement. (authors)

  10. African-American (AA) men with local-regional prostate cancer (PC) present with higher prostate specific antigen (PSA) levels than whites: results of RTOG 94-12

    International Nuclear Information System (INIS)

    Vijayakumar, S.; Winter, K.; Sause, W.; Gallagher, M.J.; Perez, C.; Bondy, M.

    1996-01-01

    Purpose/Objective: To use pretreatment serum PSA levels as an 20), gleason score (2-5,6-7,7-10), race (whites and AAs), and two interactions viz (a) PSA by race (p=0.0012) and (b) PSA by total gleason score (p=0.0001). When race was replaced by educational status, or income, or both, the fits (0.8246,0.8197, and 0.7815, respectively) were not as good as the fit with race in the model. Conclusion: The findings of this nation-wide prospective registration study with a high percentage of AA patient participation confirms previous, smaller, geographically-limited studies (1,2,3) results that AA patients with non-metastatic PC present with a higher mean PSA values than whites. The multivariate findings imply that, for each level of total gleason score, there is a higher percentage of whites with PSA levels 20. Education and/or income as surrogates of sociological status could not completely explain the racial differences. Other reasons for health-care barriers among AAs need to be identified

  11. PSA, PSA derivatives, proPSA and prostate health index in the diagnosis of prostate cancer

    OpenAIRE

    Ayyıldız, Sema Nur; Ayyıldız, Ali

    2014-01-01

    Currently, prostate- specific antigen (PSA) is the most common oncological marker used for prostate cancer screening. However, high levels of PSA in benign prostatic hyperplasia and prostatitis decrease the specificity of PSA as a cancer marker. To increase the specificity of PSA, PSA derivatives and PSA kinetics have been used. However, these new techniques were not able to increase the diagnostic specificity for prostate cancer. Therefore, the search for new molecules and derivatives of PSA...

  12. Severe accident management at the Loviisa NPP - Application of integrated ROAAM and PSA level 2

    International Nuclear Information System (INIS)

    Siltanen, S.; Routamo, T.; Tuomisto, H.; Lundstrom, P.

    2007-01-01

    The Risk Oriented Accident Analysis Methodology (ROAAM) was developed for assessment and management of rare, high consequence hazards. The purpose of most ROAAM applications has been to solve major, isolated severe accident issues related to early containment failure such as Mark-I Liner Attack and Direct Containment Heating. In addition to ROAAM in the issue resolution context, the so called Integrated ROAAM approach can be used to provide an overall frame of safety evaluation that allows determination of whether an adequate level of safety has been achieved for a plant. Integrated ROAAM approach brings together quantifications of probabilistic elements based on statistical inference and treatment of deterministic elements based on identification of dominant physics, for severe accident phenomenology, in a well defined and clearly structured way. Fortum, as an owner of the Loviisa NPP, used the Integrated ROAAM approach when developing and implementing a comprehensive severe accident management (SAM) strategy for the Loviisa NPP. The SAM strategy is based on unique features of this VVER-440 plant with ice condenser containment and it includes hardware modifications at the plant, substantial new I and C qualified for severe accident conditions, new SAM guidelines, a SAM Handbook, revision of emergency preparedness organization, and versatile training approaches. It could be argued that the resolution of individual severe accident issues is not sufficient for assessing the overall safety of a nuclear power plant, and thus the ROAAM (in an issue resolution context) is not performing the same function as a PSA study (level 2 included). Actually the Integrated ROAAM approach takes on even a more ambitious task than the PSA, since it determines how a balance can be achieved between accident prevention and mitigation of containment-threatening physical phenomena. Thus it provides a tool for implementing a sound diverse defence-in-depth strategy at a plant. Integrated

  13. Age-Specific Cutoff Value for the Application of Percent Free Prostate-Specific Antigen (PSA) in Chinese Men with Serum PSA Levels of 4.0–10.0 ng/ml

    Science.gov (United States)

    Xie, Liping; He, Dalin; Zhou, Liqun; Xu, Chuanliang; Gao, Xu; Ren, Shancheng; Wang, Fubo; Ma, Lulin; Wei, Qiang; Yin, Changjun; Tian, Ye; Sun, Zhongquan; Fu, Qiang; Ding, Qiang; Zheng, Junhua; Ye, Zhangqun; Ye, Dingwei; Xu, Danfeng; Hou, Jianquan; Xu, Kexin; Yuan, Jianlin; Gao, Xin; Liu, Chunxiao; Pan, Tiejun; Sun, Yinghao

    2015-01-01

    Objective The influence of age on the performance of percent free prostate-specific antigen (%fPSA) in diagnosing prostate cancer (PCa) in East Asians is controversial. We tested the diagnostic performance of %fPSA in a multi-center biopsy cohort in China and identified the proper age-specific cutoff values to avoid unnecessary biopsies. Methods Consecutive patients with a prostate-specific antigen (PSA) level of 4.0–10.0 ng/ml or 10.1–20.0 ng/ml who underwent transrectal ultrasound-guided or transperineal prostate biopsy were enrolled from 22 Chinese medical centers from Jan 1, 2010 to Dec 31, 2013. The diagnostic accuracy of PSA and %fPSA was determined using the area under the receiver operating characteristic (ROC) curve (AUC). Age-specific cutoff values were calculated using ROC curve analysis. Results The median %fPSA was much lower in younger patients compared with older patients with a PSA level of 4.0–10.0 ng/ml or 10.1–20.0 ng/ml. The AUC of %fPSA was higher than PSA only in older patients. In patients aged 50 to 59 years, %fPSA failed to improve the diagnosis compared with PSA in these two PSA ranges. Age-specific cutoff values were 24%, 27% and 32% for patients aged 60–69, 70–79 and ≥80 years, respectively, to reduce unnecessary biopsies in men with PSA levels of 4.0–10.0 ng/ml to detect 90% of all PCa. Conclusions The effectiveness of %fPSA is correlated with age in the Chinese population. Age-specific cutoff values would help avoid unnecessary biopsies in the Chinese population. PMID:26091007

  14. Relationship between PSA kinetics and [{sup 18}F]fluorocholine PET/CT detection rates of recurrence in patients with prostate cancer after total prostatectomy

    Energy Technology Data Exchange (ETDEWEB)

    Graute, Vera; Jansen, Nathalie; Uebleis, Christopher; Cumming, Paul; Klanke, Katharina; Tiling, Reinhold; Bartenstein, Peter; Hacker, Marcus [University of Munich, Department of Nuclear Medicine, Munich (Germany); Seitz, Michael [University of Munich, Department of Urology, Munich (Germany); Hartenbach, Markus [Bundeswehrkrankenhaus Ulm, Department of Nuclear Medicine, Ulm (Germany); Scherr, Michael Karl; Thieme, Sven [University of Munich, Institute of Clinical Radiology, Munich (Germany)

    2012-02-15

    The aim of the present study was to identify prostate-specific antigen (PSA) threshold levels, as well as PSA velocity, progression rate and doubling time in relation to the detectability and localization of recurrent lesions with [{sup 18}F]fluorocholine (FC) PET/CT in patients after radical prostatectomy. The study group comprised 82 consecutive patients with biochemical relapse after radical prostatectomy. PSA levels measured at the time of imaging were correlated with the FC PET/CT detection rates in the entire group with PSA velocity (in 48 patients), with PSA doubling time (in 47 patients) and with PSA progression (in 29 patients). FC PET/CT detected recurrent lesions in 51 of the 82 patients (62%). The median PSA value was significantly higher in PET-positive than in PET-negative patients (4.3 ng/ml vs. 1.0 ng/ml; p < 0.01). The optimal PSA threshold from ROC analysis for the detection of recurrent prostate cancer lesions was 1.74 ng/ml (AUC 0.818, 82% sensitivity, 74% specificity). Significant differences between PET-positive and PET-negative patients were found for median PSA velocity (6.4 vs. 1.1 ng/ml per year; p < 0.01) and PSA progression (5.0 vs. 0.3 ng/ml per year, p < 0.01) with corresponding optimal thresholds of 1.27 ng/ml per year and 1.28 ng/ml per year, respectively. The PSA doubling time suggested a threshold of 3.2 months, but this just failed to reach statistical significance (p = 0.071). In a study cohort of patients with biochemical recurrence of prostate cancer after radical prostatectomy there emerged clear PSA thresholds for the presence of FC PET/CT-detectable lesions. (orig.)

  15. Use of PSA Level 2 analysis for improving containment performance. Report of a technical committee meeting

    International Nuclear Information System (INIS)

    1998-03-01

    In order to discuss and exchange experience on different aspects of methods associated with Level 2 PSA and its applications for improving containment performance, the IAEA held a Technical Committee meeting in Vienna in December 1996. The meeting, which was attended by 26 participants from 20 Member States, provided a broad forum for discussion. The meeting addressed the issues related to the actual performance of Level 2 PSA studies as well as the insights gained from applications to improve containment performance. Particular attention was given to studies and applications for WWER type reactors, for which Level 2 work is still in its early stages, and for channel type reactors where modelling of accident progression is complex and significantly different from vessel type light water reactors. This TECDOC contains the papers presented at the meeting and the results of extensive discussions which were held in specific working groups

  16. The development of a relationship framework between LERF and Level-3 PSA

    International Nuclear Information System (INIS)

    Jae, Moo Sung; Jin, Young Ho; Kang, Kyung Min; Lee, Chang Ju

    2009-01-01

    The concept of LERF(Large Early Release Frequency) has been considered as a suitable metrics for making risk-informed regulatory decisions. However, the definition of 'large early release' and the associated time needs to be evaluated from the regulatory perspective and the potential implication of severe accidents. The definition of what constitutes a large early release differs a lot, and there are many parameters involved in the definition, the most important ones being the time, the amount, and the composition of the release. The underlying reason for the complexity of the release definition largely depends on the fact that the release assessment constitutes the link between the level-2 PSA results and the health effects from the release. Basically, such consequence issues are addressed in level-3 PSA, and can only be fully covered in level-3 analysis. In order to judge the acceptability of consequence results, various criteria relating between LERF and results from level 3 PSA need to be defined

  17. Age and total and free prostate-specific antigen levels for predicting prostate volume in patients with benign prostatic hyperplasia.

    Science.gov (United States)

    Coban, Soner; Doluoglu, Omer Gokhan; Keles, Ibrahim; Demirci, Hakan; Turkoglu, Ali Riza; Guzelsoy, Muhammet; Karalar, Mustafa; Demirbas, Murat

    2016-06-01

    To investigate the predictive values of free prostate-specific antigen (fPSA), total PSA (tPSA) and age on the prostate volume. The data of 2148 patients with lower urinary tract symptoms were analyzed retrospectively. The patients who had transrectal ultrasonography guided 10 core biopsies owing to the findings obtained on digital rectal examination and presence of high PSA levels (PSA = 2.5-10 ng/dl), and proven to have BPH histopathologically were included in the study. Age, tPSA, fPSA and the prostate volumes (PV) of the patients were noted. One thousand patients that fulfilled the inclusion criteria were included in the study. The PV of the patients were significantly correlated with age, tPSA and fPSA (p < 0.001 and r = 0.307, p < 0.001 and r = 0.382, p < 0.001 and r = 0.296, respectively). On linear regression model, fPSA was found as a stronger predictive for PV (AUC = 0.75, p < 0.001) when compared to age (AUC = 0.64, p < 0.001), and tPSA (AUC = 0.69, p = 0.013). Although tPSA is an important prognostic factor for predicting PV, the predictive value of fPSA is higher. PV can easily be predicted by using age, and serum tPSA and fPSA levels.

  18. Multiple external hazards compound level 3 PSA methods research of nuclear power plant

    Science.gov (United States)

    Wang, Handing; Liang, Xiaoyu; Zhang, Xiaoming; Yang, Jianfeng; Liu, Weidong; Lei, Dina

    2017-01-01

    2011 Fukushima nuclear power plant severe accident was caused by both earthquake and tsunami, which results in large amount of radioactive nuclides release. That accident has caused the radioactive contamination on the surrounding environment. Although this accident probability is extremely small, once such an accident happens that is likely to release a lot of radioactive materials into the environment, and cause radiation contamination. Therefore, studying accidents consequences is important and essential to improve nuclear power plant design and management. Level 3 PSA methods of nuclear power plant can be used to analyze radiological consequences, and quantify risk to the public health effects around nuclear power plants. Based on multiple external hazards compound level 3 PSA methods studies of nuclear power plant, and the description of the multiple external hazards compound level 3 PSA technology roadmap and important technical elements, as well as taking a coastal nuclear power plant as the reference site, we analyzed the impact of off-site consequences of nuclear power plant severe accidents caused by multiple external hazards. At last we discussed the impact of off-site consequences probabilistic risk studies and its applications under multiple external hazards compound conditions, and explained feasibility and reasonableness of emergency plans implementation.

  19. A level III PSA for the inherently safe CAREM-25 nuclear power station

    International Nuclear Information System (INIS)

    Baron, Jorge H.; Nunez McLeod, J.; Rivera, S.S.

    2000-01-01

    A Level III PSA has been performed for the inherently safe CAREM-25 nuclear power station, as a requirement for licensing according to argentinian regulations. The CAREM-25 project is still at a detailed design state, therefore only internal events have been considered, and a representative site has been assumed for dose estimations. Several conservative hypothesis have been formulated, but even so an overall core melt frequency of 2.3E -5 per reactor year has been obtained. The risk estimations comply with the regulations. The risk values obtained are compared to the 700MW(e) nuclear power plant Atucha II PSA result, showing an effective risk reduction not only in the severe accident probability but alto in the consequence component of the risk estimation. (author)

  20. Clinical impact of body mass index on prostate biopsy in patients with intermediate PSA levels

    International Nuclear Information System (INIS)

    Sekita, Nobuyuki; Chin, Kensei; Fujimura, Masaaki; Mikami, Kazuo; Suzuki, Hiroyoshi; Kamijima, Shuichi

    2008-01-01

    From April 2005 to September 2007, 480 patients underwent transrectal prostate biopsy at our institution. The clinical data including age, serum prostate specific antigen (PSA) level, prostate volume and body mass index (BMI) were obtained, and the cancer detection rates and pathological findings were evaluated in 305 cases with a PSA concentration of 4.0 to 10.0 ng/ml. Prostate volume was calculated from magnetic resonance imaging (MRI) findings. The 305 patients were categorized according to their BMI into three groups (normal, less than 22 kg/m 2 ; overweight, 22-25 kg/m 2 ; and obese, more than 25 kg/m 2 ). Cancer detection rates and histopathologic findings were compared between the groups. Multivariate logistic regression analysis was also performed. Prostate cancer was detected in 127 patients. No significant differences in BMI were observed between biopsy-positive and biopsy-negative cases (p=0.965), and the detection rates of prostate cancer observed in the three groups were not significantly different. There was a significant association between BMI and the findings of high Gleason score (more than 4+3) (p=0.048). BMI was not a contributory factor of prostate cancer detection for cases with intermediate PSA levels; however, patients with high BMI may have high-grade malignancy features. (author)

  1. Preliminary Consideration for the Development of Regulatory Level 2 PSA Model

    International Nuclear Information System (INIS)

    Lee, Chang-Ju

    2006-01-01

    In order to assess the validity of PSA (probabilistic safety assessment) results and to establish regulatory requirements for relevant safety issues most of the regulators want to develop an independent and convenient risk assessment model including Level 2 PSA area. As this model and framework should be implicitly independent on the licensee's PSA model, it has a primary objective directly for applying to the risk-informed regulatory affairs and for supporting those kinds of works. According this, the regulator can take an objective view for the uncertainty of risk information made by the licensee and keep up the capability and decision-making framework for overall risk assessment results. In addition, the regulatory model may be used to verify and validate the operational risk levels of all engineered safety features of nuclear power plants (NPPs). An issue for plant-specific application of safety goals was previously identified in the US NRC's risk-informed regulatory guidance development activities, and discussed in many Commission papers, e. g. SECY-97-287, which identifies the goal for large early release frequency (LERF). LERF defines a containment performance criteria derived from the quantitative health objectives. As we know, the LERF was chosen to assess risk significance in Regulatory Guide 1.174 (2002) again, which provides one measure of the performance of the containment barrier, and represents a surrogate for early health effects

  2. PSA levels as a predictor of 68Ga PSMA PET/CT positivity in patients with prostate cancer?

    Science.gov (United States)

    Soydal, Cigdem; Urun, Yuksel; Suer, Evren; Nak, Demet; Ozkan, Elgin; Kucuk, Ozlem N

    2018-05-10

    The aim of this study is to evaluate predictive factors of 68Gallium (68Ga) Prostate-Specific Membrane Antigen (PSMA) Positron Emission Tomography (PET)/Computed Tomography (CT) positivity. Relationships between serum Prostate Specific Antigen (PSA), Lactate dehydrogenase (LDH) and alkaline phosphatase (ALP) levels, Gleason Score (GS) and positivity of 68Ga PSMA PET in patients who underwent 68Ga PSMA PET/CT for restaging for PCa were evaluated retrospectively. One hundred and four (median age: 67; range: 51-88) patients were included in this study. Of these patients, PSMA PET was positive in 75 (72%) patients. Mean serum PSA levels for PET negative and positive groups were 0.76±1.00 and 180.85±324.93 ng/ml (pPSA cut-off and 92% and 90%, respectively, for the 2 ng/ml PSA cut-off values. The positivity rates for patients with PSA levels PSA recurrence. Patients with higher GS and early PSA recurrence could benefit from 68Ga PSMA PET/CT.

  3. Decision-making Processes among Prostate Cancer Survivors with Rising PSA Levels: Results from a Qualitative Analysis.

    Science.gov (United States)

    Shen, Megan Johnson; Nelson, Christian J; Peters, Ellen; Slovin, Susan F; Hall, Simon J; Hall, Matt; Herrera, Phapichaya Chaoprang; Leventhal, Elaine A; Leventhal, Howard; Diefenbach, Michael A

    2015-05-01

    Prostate cancer survivors with a rising prostate-specific antigen (PSA) level have few treatment options, experience a heightened state of uncertainty about their disease trajectory that might include the possibility of cancer metastasis and death, and often experience elevated levels of distress as they have to deal with a disease they thought they had conquered. Guided by self-regulation theory, the present study examined the cognitive and affective processes involved in shared decision making between physicians and patients who experience a rising PSA after definitive treatment for prostate cancer. In-depth interviews were conducted with 34 prostate cancer survivors who had been diagnosed with a rising PSA (i.e., biochemical failure) within the past 12 months. Survivors were asked about their experiences and affective responses after being diagnosed with a rising PSA and while weighing potential treatment options. In addition, patients were asked about their decision-making process for the initial prostate cancer treatment. Compared with the initial diagnosis, survivors with a rising PSA reported increased negative affect following their diagnosis, concern about the treatability of their disease, increased planning and health behavior change, heightened levels of worry preceding doctor appointments (especially prior to the discussion of PSA testing results), and a strong reliance on physicians' treatment recommendations. Prostate cancer survivors' decision-making processes for the treatment of a rising PSA are markedly different from those of the initial diagnosis of prostate cancer. Because patients experience heightened distress and rely more heavily on their physicians' recommendations with a rising PSA, interactions with the health care provider provide an excellent opportunity to address and assist patients with managing the uncertainty and distress inherent with rising PSA levels. © The Author(s) 2014.

  4. Extent of disease in recurrent prostate cancer determined by [(68)Ga]PSMA-HBED-CC PET/CT in relation to PSA levels, PSA doubling time and Gleason score.

    Science.gov (United States)

    Verburg, Frederik A; Pfister, David; Heidenreich, Axel; Vogg, Andreas; Drude, Natascha I; Vöö, Stefan; Mottaghy, Felix M; Behrendt, Florian F

    2016-03-01

    To examine the relationship between the extent of disease determined by [(68)Ga]PSMA-HBED-CC-PET/CT and the important clinical measures prostate-specific antigen (PSA), PSA doubling time (PSAdt) and Gleason score. We retrospectively studied the first 155 patients with recurrent prostate cancer (PCA) referred to our university hospital for [(68)Ga]PSMA-HBED-CC PET/CT. PET/CT was positive in 44%, 79% and 89% of patients with PSA levels of ≤1, 1-2 and ≥2 ng/ml, respectively. Patients with high PSA levels showed higher rates of local prostate tumours (p PSA and PSAdt were independent determinants of scan positivity and of extrapelvic lymph node metastases. PSAdt was the only independent marker of bone metastases (p = 0.001). Of 20 patients with a PSAdt PSA ≥2 ng/ml, 19 (95%) had a positive scan and 12 (60%) had M1a disease. Of 14 patients with PSA 6 months, only 5 (36%) had a positive scan and 1 (7%) had M1a disease. [(68)Ga]PSMA-HBED-CC PET/CT will identify PCA lesions even in patients with very low PSA levels. Higher PSA levels and shorter PSAdt are independently associated with scan positivity and extrapelvic metastases, and can be used for patient selection for [(68)Ga]PSMA-HBED-CC PET/CT.

  5. The Role of Level-3 PSA in the Regulatory Structure for the Licensing of Future NPPs

    International Nuclear Information System (INIS)

    Jeong, Jong Tae; Han, Sang Hoon

    2008-01-01

    accomplished. Therefore, the role of Level-3 PSA for the evaluation of dose consequences will be examined in this study

  6. External hazards analysis approach to level 1 PSA of Mochovce NPP - Slovakia

    International Nuclear Information System (INIS)

    Stojka, Tibor

    2000-01-01

    Analyses of external events had been first time performed at the design stage of the Mochovce NPP showing sufficiently low contribution of external hazards to core damage frequency. But, based on IAEA document 'Safety problems of WWER-440/213 NPPs and the categorization' (IAEA-EBP-WWER-03, 1996), the need of new reassessment arose due to discrepancy of some origin recommendations in compare with present IAEA ones. Mochovce NPP Nuclear Safety Improvements Program elaborated at the same time included the IAEA recommendations and following improvements were proposed to perform in context of external events. 1. Seismic project and new locality seismic evaluation This safety improvement includes also some 'on site' technical improvements in seismic stability of structures and equipment. 2. Unit specific analyses of extreme meteorologic conditions. This safety improvement focuses on impact of feasible extreme conditions on NPP systems caused by rain, snow and hail storms, frost, winds, low and high temperatures. 3. Analyses of external hazards caused by humans. In this safety improvement were specified: feasible sources of explosions; analyses of hydrogen, gas and propane-calor gas depots; air crash risk. The results of these implemented safety improvements were considered in the PSA study. The External hazards analysis is also part of Level 1 PSA Mochovce NPP performed by PSA Department of VUJE Trnava Inc., Engineering, Design and Research Organization, Slovakia. Some partial analyses are performed in cooperation with following companies DS and S - SAIC, USA and Geophysical Institute Academy of Science, Slovakia Relko, Slovakia. Basic documents are: NUREG/CR-2300 'PRA Procedures Guide - A Guide to the Performance of Probabilistic Risk Assessments for Nuclear Power Plants' and IAEA SS No. 50-P-7 'Treatment of External Hazards in PSA for NPPs. The external hazards analysis consists of following parts: 1. Geography and plant locality; 2. Nearby industry; 3. Extreme

  7. Impact of radiation dose on achieving nadir PSA levels after 3-dimensional conformal radiotherapy for patients with localized prostate cancer

    International Nuclear Information System (INIS)

    Zelefsky, Michael J.; Leibel, Steven A.; Kelson, Suzanne; Fuks, Zvi

    1996-01-01

    Purpose: Several reports have documented the prognostic value of a post-irradiation nadir PSA of ≤1 ng/ml in prostatic cancer patients. The purpose of this study was to determine which pre-treatment and treatment-related variables impact upon achieving such nadir levels. Materials and Methods: Between January 1987 and June 1995, 740 patients with clinically localized prostate cancer were treated with 3-dimensional conformal radiotherapy (3D-CRT). 214 (29%) patients were treated with neo-adjuvant androgen ablation prior to therapy and were excluded from this analysis. Among the 526 evaluable patients, the clinical stage were as follows: T 1 C=128 (24%); T 2 A=76 (14%); T 2 B=116 (22%); T 2 C=99 (19%) and T 3 =107 (21%). The prescription dose to the planning target volume (PTV) was 64.8-68.4 Gy in 87 patients (17%); 70.2 Gy in 191 (36%); 75.6 Gy in 209 (40%) and 81 Gy in 39 (7%). The median pre-treatment PSA value was 11.2 ng/ml (range 0.3-114). The median follow-up was 20 months (range: 6-76 months). Results: 242 patients (46%) had PSA levels which declined to ≤1.0 ng/ml. The median time to a nadir level of ≤1.0 was 15.6 months (range: 1-43 months) from completion of 3D-CRT. 154 (29%) patients continued to show declining PSA levels within the first 2 years after therapy, and 130 patients (25%) failed to nadir at PSA levels of ≤1.0 ng/ml. Among patients with nadir PSA levels ≤1, the 3 year PSA relapse-free survival was 91% compared to 29% for patients with nadir PSA levels >1 ng/ml (p<0.0001). A Cox-regression analysis demonstrated that nadir PSA ≤1 was the strongest predictor of PSA relapse-free survival (p<0.001) followed by Gleason score ≤ 6 (p<0.001) and stage< T3 (p=0.004). Among patients who received doses of ≥75.6 Gy, the likelihood of achieving PSA nadir levels ≤1.0 at 24 and 36 months was 86% and 93%, respectively, compared to 74 and 80%, respectively, among those who received lower doses (p<0.001). Doses of ≥75.6 Gy was the strongest

  8. MODIFICATION OF THE SPAR-H METHOD TO SUPPORT HRA FOR LEVEL 2 PSA

    Energy Technology Data Exchange (ETDEWEB)

    St. Germain, S.; Boring, R.; Banaseanu, G.; Akl, Y.; Xu, M.

    2016-10-01

    Currently, available Human Reliability Analysis (HRA) methods were generally developed to support Level 1 Probabilistic Safety Analysis (PSA) models. There has been an increased emphasis placed on Level 2 PSA in recent years; however, the currently used HRA methods are not ideal for this application, including the SPAR-H method. Challenges that will likely be present during a severe accident such as degraded or hazardous operating conditions, shift in control from the main control room to the technical support center, unavailability of instrumentation, and others are not routinely considered for Level 1 HRA analysis. These factors combine to create a much more uncertain condition to be accounted for in the HRA analysis. While the SPAR-H shaping factors were established to support Level 1 HRA, previous studies have shown it may be used for Level 2 HRA analysis as well. The Canadian Nuclear Safety Commission (CNSC) and Idaho National Laboratory (INL) in a joint project are investigating modifications to the SPAR-H method to create more consistency in applying the performance shaping factors used in the method for Level 2 analysis.

  9. Quality PSA for PSA applications

    International Nuclear Information System (INIS)

    Carska, K.; Rybar, J.

    2012-03-01

    The safety guideline defines with more precision Nuclear Regulatory Authority of the Slovak Republic requirements of the quality of probabilistic safety assessment (PSA) for PSA application. Term of quality of PSA is explained in detail. Procedure for determining the quality of PSA is provided. The categorization of PSA study according the quality of PSA is suggested. A comprehensive list of PSA applications for nuclear facilities is provided. What technical features of a PSA should be satisfied to support the PSA applications of interest is stated. (authors)

  10. Atmospheric Dispersion Simulation for Level 3 PSA at Ulchin Nuclear Site using a PUFF model

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Seung Jun; Han, Seok-Jung; Jeong, Hyojoon; Jang, Seung-Cheol [KAERI, Daejeon (Korea, Republic of)

    2015-05-15

    Air dispersion prediction is a key in the level 3 PSA to predict radiation releases into the environment for preparing an effective strategy for an evacuation as a basis of the emergency preparedness. To predict the atmospheric dispersion accurately, the specific conditions of the radiation release location should be considered. There are various level 3 PSA tools and MACSS2 is one of the widely used level 3 PSA tools in many countries including Korea. Due to the characteristics of environmental conditions in Korea, it should be demonstrated that environmental conditions of Korea nuclear sites can be appropriately illustrated by the tool. In Korea, because all nuclear power plants are located on coasts, sea and land breezes might be a significant factor. The objectives of this work is to simulate the atmospheric dispersion for Ulchin nuclear site in Korea using a PUFF model and to generate the data which can be used for the comparison with that of PLUME model. A nuclear site has own atmospheric dispersion characteristics. Especially in Korea, nuclear sites are located at coasts and it is expected that see and land breeze effects are relatively high. In this work, the atmospheric dispersion at Ulchin nuclear site was simulated to evaluate the effect of see and land breezes in four seasons. In the simulation results, it was observed that the wind direction change with time has a large effect on atmospheric dispersion. If the result of a PLUME model is more conservative than most severe case of a PUFF model, then the PLUME model could be used for Korea nuclear sites in terms of safety assessment.

  11. A source term and risk calculations using level 2+PSA methodology

    International Nuclear Information System (INIS)

    Park, S. I.; Jea, M. S.; Jeon, K. D.

    2002-01-01

    The scope of Level 2+ PSA includes the assessment of dose risk which is associated with the exposures of the radioactive nuclides escaping from nuclear power plants during severe accidents. The establishment of data base for the exposure dose in Korea nuclear power plants may contribute to preparing the accident management programs and periodic safety reviews. In this study the ORIGEN, MELCOR and MACCS code were employed to produce a integrated framework to assess the radiation source term risk. The framework was applied to a reference plant. Using IPE results, the dose rate for the reference plant was calculated quantitatively

  12. Relationships between serum PSA levels, Gleason scores and results of 68Ga-PSMAPET/CT in patients with recurrent prostate cancer.

    Science.gov (United States)

    Sanli, Yasemin; Kuyumcu, Serkan; Sanli, Oner; Buyukkaya, Fikret; İribaş, Ayça; Alcin, Goksel; Darendeliler, Emin; Ozluk, Yasemin; Yildiz, Sevda Ozel; Turkmen, Cüneyt

    2017-11-01

    To investigate the relationship between serum PSA level, Gleason score of PCa and the outcomes of Ga 68 -PSMA PET/CT in patients with recurrent PCa. A total of 109 consecutive patients (median age 71 years; range 48-89 years) who had PSA recurrence after RP and/or hormonotherapy and/or radiotherapy were included in this study. Local recurrences, lymph node metastasis (pelvic, abdominal and/or supradiaphragmatic), bone metastases (oligometastatic/multimetastatic) and other metastatic sites (lung, liver, brain, etc) were documented. In 91(83.4%) patients at least one lesion characteristic for PCa was detected by 68 Ga-PSMA PET/CT. The median serum total PSA (tPSA) was 6.5 (0.2-640) ng/ml.There was a significant difference between 68 Ga-PSMA PET/CT positive and negative patients in terms of serum total PSA value. No statistical significance was found between positive and negative 68 Ga-PSMA PET/CT findings in terms of Gleason score. Local recurrence was detected in 56 patients. whereas lymph node metastases were demonstrated in 46 patients. Pelvic nodal disease was the most frequent presentation followed by abdominal and supradiaphragmaticnodal involvement. Bone metastases [oligometastasis, (n = 20); multimetastasis, (n = 35)⦌ were also detected in 55 patients. In the ROC analysis for the study cohort, the optimal cut-off value of total serum PSA was determined as 0.67 ng/ml for distinguishing between positive and negative 68 Ga-PSMA PET/CT images, with an area under curve of 0.952 (95% CI 0.911-0.993). 68 Ga-PSMA PET/CT was found to be an effective tool for the detection of recurrent PCa. Even though no relationship was detected between the GS and 68 Ga-PSMA PET/CT findings, serum total PSA values may be used for estimating the likelihood of positive 68 Ga-PSMA PET/CT results.

  13. The Effect of Increasing Doses of Saw Palmetto Fruit Extract on Serum PSA Levels: Analysis of the CAMUS Randomized Trial

    Science.gov (United States)

    Andriole, Gerald L.; McCullum-Hill, Christie; Sandhu, Gurdarshan S.; Crawford, E. David; Barry, Michael J.; Cantor, Alan

    2014-01-01

    Purpose Saw palmetto extracts are used for treating lower urinary tract symptoms in men despite level I evidence concluding that saw palmetto was ineffective in reducing lower urinary symptoms. We sought to determine whether higher doses of saw palmetto as studied in CAMUS affect serum PSA levels. Materials and Methods The CAMUS trial was a randomized, placebo-controlled double blind multi-centered North American trial conducted between June 5, 2008 and October 10, 2012 in which 369 men >45 years of age with AUA symptom score ≥ 8 and ≤ 24 were randomly assigned to placebo or dose escalation saw palmetto, which consisted of 320mg for first 24 weeks to 640mg for next 24 weeks to 960mg for last 24 weeks of this 72 week trial. Serum PSA levels (Beckman-Coulter) were obtained at baseline and at weeks 24, 48 and 72 and were compared between treatment groups using the pooled t and Fisher's exact tests. Results Serum PSA levels were similar at baseline for the placebo (1.93 ± 1.59 ng/ml) and saw palmetto groups (2.20 ± 1.95, p = 0.16). Changes in PSA levels over the course of the study were similar: placebo group mean change 0.16 ± 1.08 ng/ml and saw palmetto group mean change 0.23 ± 0.83 ng/ml (p value 0.50). Additionally, no differential effect on serum PSA levels was observed between treatment arms when groups were stratified by baseline PSA values. Conclusions Saw palmetto extract does not affect serum PSA levels more than placebo even at relatively high doses. PMID:23253958

  14. Severe Accident Research Network (SARNET). Level 2 PSA work package: comparison of partners methods for uncertainties assessment

    International Nuclear Information System (INIS)

    Chaumont, B.; Haesendonck, M.; Vidal, S.; Eyink, J.; Loeffler, H.; Radu, G.; Kopustinskas, V.; Ming, A.; Guntay, S.; Gustavsson, V.; Ivanov, I.; Dienstbier, J.; Bareith, A.; Hollo, E.; Lajtha, G.

    2007-01-01

    The PSA2 work package (PSA2 WP) is a part of the Joined Programme Activity of the European Severe Accident Network (SARNET) related to level 2 PSA methodologies. The general objectives of this work package is to provide a comparison of the different methodologies used or under development for level 2 PSA application by the partners involved in the work package and to promote their harmonization. The PSA2 WP is organized into three main topics: methodologies in general, methodologies for uncertainties assessment, and dynamic reliability methods. The different tasks initially defined for these three topics are shortly described and the partners involved identified. Attention is then paid on the methodologies used so far by the different partners to assess the uncertainties in their level 2 PSA. A review of partners approaches to assess - as far as possible - the different sources of possible uncertainties is done for the different following topics: - uncertainties propagated from the level 1 PSA, - uncertainties (in sense of approximation) due to the binning of the level 1 sequences in Plant Damage, - uncertainties related to the structure of the Accident Progression Event Tree, - uncertainties related to the probabilities of stochastic events (system failure or recovery, human actions, some physical phenomena such as ignition of hydrogen combustion or triggering of steam explosion), - uncertainties elated to the modelling of the different physical phenomena, - uncertainties related to the cut-off frequency used in the probabilistic quantification of the Accident Progression Event Tree; - uncertainties related to the binning of level 2 sequences in Release Categories (variables not considered, values of eventual continuous variables). First conclusions of the comparison are given in terms of improvement needs and then of perspectives of the work for the following period of work. (authors)

  15. Measurements of free and total PSA, tissue polypeptide-specific antigen (TPS), and CYFRA 21-1 in prostate cancer patients under intermittent androgen suppression therapy.

    Science.gov (United States)

    Theyer, G; Dürer, A; Theyer, U; Haberl, I; Ulsperger, E; Baumgartner, G; Hamilton, G

    1999-10-01

    The present study evaluated monthly measurements of free and total prostate-specific antigen (PSA), and the tumor proliferation markers tissue polypeptide-specific antigen (TPS) and cytokeratin fragment 21-1 (CYFRA 21-1) in patients with advanced prostate cancer receiving intermittent androgen suppression therapy (IAS). Thirty-four men received alternating cycles of 8 month androgen suppression and treatment cessation (mean duration, 10.3 months) until PSA increased to >20 microg/l. Measurements of testosterone, percentage of free PSA, TPS, and CYFRA 21-1 were performed using ELISA and RIA assays. Periods of androgen suppression resulted in reversible reductions of testosterone (from 6 +/- 0.8 to IAS cycle. TPS showed a decrease of 50% after 3 months, and CYFRA 21-1 a 25% decrease after 7 months of androgen suppression treatment. During treatment cessation, TPS exceeded the normal cutoff value of 90 U/l late in tumor regrowth (9-11 months), whereas CYFRA 21-1 remained below the normal cutoff value of 3.3 ng/ml. PSA is the best and most sensitive marker of prostate cancer regression and regrowth during IAS cycles of the markers tested in this study. Free PSA constitutes approximately 15% of total PSA (range, 5-32%), and its percentage showed no significant change during IAS cycles. The TPS and CYFRA 21-1 proliferation marker changes in IAS seem to be related mainly to effects on normal androgen-dependent tissues. Copyright 1999 Wiley-Liss, Inc.

  16. Research on the improvement of nuclear safety -Development of computing code system for level 3 PSA

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Jong Tae; Kim, Dong Ha; Park, Won Seok; Hwang, Mi Jeong [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1995-07-01

    Among the various research areas of the level 3 PSA, the effect of terrain on the transport of radioactive material was investigated. These results will give a physical insight in the development of a new dispersion model. A wind tunnel experiment with bell shaped hill model was made in order to develop a new dispersion model. And an improved dispersion model was developed based on the concentration distribution data obtained from the wind tunnel experiment. This model will be added as an option to the atmospheric dispersion code. A stand-alone atmospheric code using MS Visual Basic programming language which runs at the Windows environment of a PC was developed. A user can easily select a necessary data file and type input data by clicking menus, and can select calculation options such building wake, plume rise etc., if necessary. And a user can easily understand the meaning of concentration distribution on the map around the plant site as well as output files. Also the methodologies for the estimation of radiation exposure and for the calculation of risks was established. These methodologies will be used for the development of modules for the radiation exposure and risks respectively. These modules will be developed independently and finally will be combined to the atmospheric dispersion code in order to develop a level 3 PSA code. 30 tabs., 56 figs., refs. (Author).

  17. Research on the improvement of nuclear safety -Development of computing code system for level 3 PSA

    International Nuclear Information System (INIS)

    Jeong, Jong Tae; Kim, Dong Ha; Park, Won Seok; Hwang, Mi Jeong

    1995-07-01

    Among the various research areas of the level 3 PSA, the effect of terrain on the transport of radioactive material was investigated. These results will give a physical insight in the development of a new dispersion model. A wind tunnel experiment with bell shaped hill model was made in order to develop a new dispersion model. And an improved dispersion model was developed based on the concentration distribution data obtained from the wind tunnel experiment. This model will be added as an option to the atmospheric dispersion code. A stand-alone atmospheric code using MS Visual Basic programming language which runs at the Windows environment of a PC was developed. A user can easily select a necessary data file and type input data by clicking menus, and can select calculation options such building wake, plume rise etc., if necessary. And a user can easily understand the meaning of concentration distribution on the map around the plant site as well as output files. Also the methodologies for the estimation of radiation exposure and for the calculation of risks was established. These methodologies will be used for the development of modules for the radiation exposure and risks respectively. These modules will be developed independently and finally will be combined to the atmospheric dispersion code in order to develop a level 3 PSA code. 30 tabs., 56 figs., refs. (Author)

  18. Improving PSA quality of KSNP PSA model

    International Nuclear Information System (INIS)

    Yang, Joon Eon; Ha, Jae Joo

    2004-01-01

    In the RIR (Risk-informed Regulation), PSA (Probabilistic Safety Assessment) plays a major role because it provides overall risk insights for the regulatory body and utility. Therefore, the scope, the level of details and the technical adequacy of PSA, i.e. the quality of PSA is to be ensured for the successful RIR. To improve the quality of Korean PSA, we evaluate the quality of the KSNP (Korean Standard Nuclear Power Plant) internal full-power PSA model based on the 'ASME PRA Standard' and the 'NEI PRA Peer Review Process Guidance.' As a working group, PSA experts of the regulatory body and industry also participated in the evaluation process. It is finally judged that the overall quality of the KSNP PSA is between the ASME Standard Capability Category I and II. We also derive some items to be improved for upgrading the quality of the PSA up to the ASME Standard Capability Category II. In this paper, we show the result of quality evaluation, and the activities to improve the quality of the KSNP PSA model

  19. Development of a fully-coupled, all atates, all hazards level 2 PSA at leibstadt nuclear power plant

    Energy Technology Data Exchange (ETDEWEB)

    Zvoncek, Pavol; Nusbaumer, Olivier [Safety Compliance and Technical Support Department, Leibstadt Nuclear Power Plant, Leibstadt (Sweden); Torri, Alfred [Risk Management Associates, Inc., Encinitas (United States)

    2017-03-15

    This paper describes the development process, the innovative techniques used and insights gained from the latest integrated, full scope, multistate Level 2 PSA analysis conducted at the Leibstadt Nuclear Power Plant (KKL), Switzerland. KKL is a modern single-unit General Electric Boiling Water Reactor (BWR/6) with Mark III Containment, and a power output of 3600MWth/1200MWe, the highest among the five operating reactors in Switzerland. A Level 2 Probabilistic Safety Assessment (PSA) analyses accident phenomena in nuclear power plants, identifies ways in which radioactive releases from plants can occur and estimates release pathways, magnitude and frequency. This paper attempts to give an overview of the advanced modeling techniques that have been developed and implemented for the recent KKL Level 2 PSA update, with the aim of systematizing the analysis and modeling processes, as well as complying with the relatively prescriptive Swiss requirements for PSA. The analysis provides significant insights into the absolute and relative importance of risk contributors and accident prevention and mitigation measures. Thanks to several newly developed techniques and an integrated approach, the KKL Level 2 PSA report exhibits a high degree of reviewability and maintainability, and transparently highlights the most important risk contributors to Large Early Release Frequency (LERF) with respect to initiating events, components, operator actions or seismic component failure probabilities (fragilities)

  20. Radiometric assays for the measurement of PSA

    International Nuclear Information System (INIS)

    Venkatesh, M.

    1997-01-01

    Prostate Specific Antigen, a serine protease enzyme, of M.W. ∼ 26-33 kDa, is widely considered to be a very useful marker for prostate cancer. It satisfies nearly all the requirements of an ideal 'Tumour Marker' and has hence attracted a lot of attention in the past decade. PSA is present in multiple forms in serum, with an appreciable fraction bound to the protease inhibitor α-1-antichymotrypsin (ACT) and to a small extent to other proteins such as α-2-macroglobulin (AMG) leaving the rest in the free form. The total PSA levels have been reported to have 80% sensitivity and 60% specificity towards the detection of prostate cancer. The lack of specificity occurs mainly due to the high levels of t-PSA in benign prostatic hypertrophy(BPH) apart from the cancer. The concept of free PSA has been introduced in the recent past and the ratio of free/total PSA levels have been shown to be advantageous in the differential diagnosis of BPH from prostate cancer. The f/t ratio is considered to be particularly useful in the grey zones of decision making (t-PSA levels 4-20 ng/mL). The need for the development of assays for total and free PSA is felt due to: a. the high incidence of prostate cancers being detected currently; b. the high cost of tests (higher for free PSA assay, and the cost becomes an important parameter when a patient has to be regularly monitored after therapy) that is not affordable for many patients; c. the potential for research in the area of prostate cancer management where the PSA (total and free) assays will be of great help

  1. Main factors determining the KNP units 5 and 6 safety level according to the PSA level 1 result

    International Nuclear Information System (INIS)

    Manchev, B.; Marinova, B.; Nenkova, B.

    2004-01-01

    The Probabilistic Safety Analysis (PSA) is a powerful tool for ascertainment of the safety level reached at nuclear power plants operation. The results of PSA determine very clearly the functions, systems, equipment or operator actions that have to be improved in order to increase the plant safety level as a whole. The present report presents the main results of the last upgraded revision of PSA level 1 of units 5 and 6 of KNPP. The objective of the report is to lay emphasis on the factors determining the result obtained, i.e. to demonstrate the scopes whose improvement leads to an increase of the safety level reached at the units power operation. In the frame of the study presented the following categories of initiating events are included: Internal initiating events; Initiating events result of internal fires; Initiating events result of seismic action; Floods. Only the reactor core is considered as a source of radioactive contamination. Only initiating events related to the reactor work on power are analyzed. Unit 5 of KNPP is accepted as a basic unit for the study. All modifications and design changes implemented up to year 2000 are taken into account. The results of PSA level 1 for units 5 and 6 of KNPP covering the risk of internal initiators are presented. The assessment of the core damage due to internal initiators is based on the analysis of 18 groups of initiating events. 932 consequences and two groups of initial events are identified, leading to core damage. As a result of the quantitative calculation, over 15000 minimal cuts for the core damage are obtained. The first 80 cuts bear over 75% of the frequency obtained, and the first 700 cuts bear over 90%. Distribution of the core damage frequency by different groups of initiators is presented in tables and diagrams. A comparison of the result obtained for the reactor core damage of KNPP units 5 and 6 with assessment obtained for similar power plants is presented. The data for different NPPs are taken

  2. Achievement of the level 1 PSA in support to the CEA 2400 MWth gas-cooled fast reactor

    International Nuclear Information System (INIS)

    Balmain, M.; Bassi, C.; Azria, P.

    2012-01-01

    Within Generation IV International Forum, the CEA has developed since 2006 a Level 1 PSA to support the design of the 2400 MWth GFR (Gas-cooled Fast Reactor). A first period, with insights published in 2008, consisted in a model with few initiators representative of medium and high pressure situations, those used for the deterministic design of the Decay Heat Removal (DHR) dedicated loops. In a second period, an iterative work reached the probabilistic targets used for generation III reactors, with prior use of normal loops, and increase of DHR reliability in high pressure conditions. The PSA team covered all the internal initiators, and supported the design of components with instrumentation and control and electrical supplies, and the shutdown operating modes of secondary, tertiary circuits, with possible re-alignment to dedicated DHR loops. Besides, the completed PSA integrated more realistic success criteria than the preliminary model and than the deterministic approach, thanks to CATHARE2 code. In case of loss of Forced Convection, the probability of success of the Natural Convection DHR was assessed by a reliability method for passive systems. The paper underlines the PSA methodology knowledge from the EDF expertise, the improvements co-developed with CEA, and the iteration design-PSA-design. (authors)

  3. Validation of Association of Genetic Variants at 10q with PSA Levels in Men at High Risk for Prostate Cancer

    Science.gov (United States)

    Chang, Bao-Li; Hughes, Lucinda; Chen, David Y. T.; Gross, Laura; Ruth, Karen; Giri, Veda N.

    2013-01-01

    Objectives Men with a family history of prostate cancer and African American men are at increased risk for prostate cancer and stand to benefit from individualized interpretation of PSA to guide screening strategies. The purpose of this study was to validate six previously identified markers among high-risk men enrolled in the Prostate Cancer Risk Assessment Program - a prostate cancer screening study. Patients and Methods Eligibility for PRAP includes men ages 35–69 years with a family history of prostate cancer, any African American male regardless of family history, and men with known BRCA gene mutations. GWAS markers assessed included rs2736098 (5p15.33), rs10993994 (10q11), rs10788160 (10q26), rs11067228 (12q24), rs4430796 (17q12), and rs17632542 (19q13.33). Genotyping methods included either Taqman® SNP Genotyping Assay (Applied Biosystems) or pyrosequencing. Linear regression models were used to evaluate the association between individual markers and log-transformed baseline PSA levels, while adjusting for potential confounders. Results 707 participants (37% Caucasian, 63% African American) with clinical and genotype data were included in the analysis. Rs10788160 (10q26) strongly associated with PSA levels among high-risk Caucasian participants (p<0.01), with a 33.2% increase in PSA level with each A-allele carried. Furthermore, rs10993994 (10q11) demonstrated an association to PSA level (p=0.03) in high-risk Caucasian men, with a 15% increase in PSA with each T-allele carried. A PSA adjustment model based on allele carrier status at rs10788160 and rs10993994 is proposed specific to high-risk Caucasian men. Conclusion Genetic variation at 10q may be particularly important in personalizing interpretation of PSA for high-risk Caucasian men. Such information may have clinical relevance in shared decision-making and individualized prostate cancer screening strategies for high-risk Caucasian men. Further study is warranted. PMID:23937305

  4. Living PSA

    International Nuclear Information System (INIS)

    Evans, M.G.K.

    1997-01-01

    The aim of this presentation is to gain an understanding of the requirements for a PSA to be considered a Living PSA. The presentation is divided into the following topics: Definition; Planning/Documentation; Task Performance; Maintenance; Management. 4 figs

  5. The relationship between serum PSA, six sex hormones and the benign or malignant prostate diseases

    International Nuclear Information System (INIS)

    Xu Yancun

    2008-01-01

    In order to study clinical significance of serum prostate-specific antigen (PSA), free prostate specific antigen (PSA), f/tPSA and six sex hormones in prostate diseases, the serum levels of PSA, fPSA, f/tPSA, T, P, E 2 , PRL, LH and FSH in 72 cases of hyperplasia of prostate patients and 40 patients with prostate cancer were determined by RIA. The results showed that the serum levels of T, E 2 , PRL, LH, FSH in the BPH Group were significantly lower than those of in Pca group, the serum level of P in Pca group were significantly lower than those in BPH group; the levels of fPSA and f/tPSA ratio in BPH Group were significantly higher than those in Pca group. The results suggest that benign and malignant prostate disease (BPH and Pca) was related with the hormone imbalance. The serum total PSA and fPSA can be regarded as important indicators in the diagnosis of BPH and Pea. The combined determination of PSA, fPSA and f/tPSA may improve the diagnostic accuracy of Pca. (authors)

  6. Plasma carotenoids and tocopherols in relation to prostate-specific antigen (PSA) levels among men with biochemical recurrence of prostate cancer.

    Science.gov (United States)

    Antwi, Samuel O; Steck, Susan E; Zhang, Hongmei; Stumm, Lareissa; Zhang, Jiajia; Hurley, Thomas G; Hebert, James R

    2015-10-01

    Although men presenting with clinically localized prostate cancer (PrCA) often are treated with radical prostatectomy or radiation therapy with curative intent, about 25-40% develop biochemically recurrent PrCA within 5 years of treatment, which has no known cure. Studies suggest that carotenoid and tocopherol intake may be associated with PrCA risk and progression. We examined plasma carotenoid and tocopherol levels in relation to prostate-specific antigen (PSA) levels among men with PSA-defined biochemical recurrence of PrCA. Data analyzed were from a 6-month diet, physical activity and stress-reduction intervention trial conducted in South Carolina among biochemically recurrent PrCA patients (n=39). Plasma carotenoids and tocopherol levels were measured using high-performance liquid chromatography (HPLC). Linear regression was used to estimate least-square means comparing PSA levels of men with high versus low carotenoid/tocopherol levels, adjusting for covariates. After adjusting for baseline PSA level, plasma cis-lutein/zeaxanthin level at 3 months was related inversely to PSA level at 3 months (P=0.0008), while α-tocopherol (P=0.01), β-cryptoxanthin (P=0.01), and all-trans-lycopene (P=0.004) levels at 3 months were related inversely to PSA levels at 6-months. Percent increase in α-tocopherol and trans-β-carotene levels from baseline to month 3 were associated with lower PSA levels at 3 and 6 months. Percent increase in β-cryptoxanthin, cis-lutein/zeaxanthin and all-trans-lycopene were associated with lower PSA levels at 6 months only. Certain plasma carotenoids and tocopherols were related inversely to PSA levels at various timepoints, suggesting that greater intake of foods containing these micronutrients might be beneficial to men with PSA-defined PrCA recurrence. Copyright © 2015. Published by Elsevier Ltd.

  7. Attributes of Full Scope Level 1 Probabilistic Safety Assessment (PSA) for Applications in Nuclear Power Plants

    International Nuclear Information System (INIS)

    2016-10-01

    This publication supersedes IAEA-TECDOC-1511, Determining the Quality of Probabilistic Safety Assessment (PSA) for Applications in Nuclear Power Plants (published in 2006), which provided detailed information on technical features of a restricted scope PSA aimed at analysing only internal initiating events caused by random component failures and human errors, and accident sequences that may lead to reactor core damage during operation. The present publication extends the scope of the PSA to cover a broader range of internal and external hazards, and low power and shutdown modes of nuclear power plant operation. In addition, some PSA aspects relevant to lessons learned from the accident at the Fukushima Daiichi nuclear power plant are also considered

  8. THE DISCRIMINATIVE ABILITY OF PERCENT FREE PSA IN ...

    African Journals Online (AJOL)

    Blood samples were collected from all patients, and total PSA, free PSA and % free PSA were calculated in all specimens. Total PSA was measured using the Imx ... Un prélèvement de sang a été réalisé chez tous les patients avec un dosage du PSA total et de la fraction libre de PSA. Le PSA total a été mesuré par un kit ...

  9. DIAGNOSTIC AND PROGNOSTIC UTILITY OF SERUM PSA IN BREAST CANCER

    Institute of Scientific and Technical Information of China (English)

    张淑群; 强水云; 李妙羡; 纪宗正

    2004-01-01

    Objective To investigate the diagnostic and prognostic value of total and free prostate-specific antigen (PSA) in breast cancer women. Methods Using the microparticle enzyme immunoassay system, we measured the concentrations of these markers in the sera of 85 women with breast cancer and in 30 healthy women.Results Free PSA levels were significantly higher in women with breast cancer than healthy women (P <0. 05 ).The percentage of free PSA predominant subjects was 37. 6% in breast cancer patients and 3. 3% in healthy women.In women with breast cancer,total PSA positivity was 23.5% and free PSA positivity was 27. 1%. When compared to negatives,total PSA positive patients had a higher percentage of lymph node involvement tamours ( P >0. 05).However, patients with predominant free PSA had a higher percentage of early stage than patients with predominant PSA-ACT. Conclusion This study indicate clinical significance of preoperative measurement of serum total and free PSA in diagnosis and prognosis of women with breast cancer. The expression of KLKs is correlated with carcinogenesis of breast cancer.

  10. Transrectal ultrasound in detecting prostate cancer compared with serum total prostate-specific antigen levels

    International Nuclear Information System (INIS)

    Tamsel, S.; Killi, R.; Demirpolat, G.; Hekimgil, M.; Soydan, S.; Altay, B.

    2008-01-01

    We carried out a retrospective study to review the efficiency of grey-scale transrectal ultrasonography (TRUS) in detecting prostate cancer compared with the data in recent published work, including alternative imaging methods of the prostate gland. Our study group consisted of 830 patients who underwent TRUS-guided biopsy of the prostate between May 2000 and June 2004. The relation between abnormal TRUS findings and serum total prostate-specific antigen (tPSA) levels was evaluated in patients with prostate cancer who were divided into three different groups according to serum tPSA levels. Group I included patients with tPSA levels of 4-9.9 ng/mL, group II included tPSA levels of 10-19.9 ng/mL and group III included patients with tPSA levels of 20 ng/mL or more. In general, TRUS detected 185 (64%) of 291 cancers with a specificity of 89%, a PPV of 76% and an accuracy of 80%. TRUS findings enabled the correct identification of 22 (56%) of the 39 cancers in group I, 28 (30%) of the 93 cancers in group II and 135 (85%) of the 159 cancers in group III. In conclusion, TRUS alone has a limited potential to identify prostate cancer, especially in patients with tPSA levels lower than 20 ng/mL. Therefore, increased numbers of systematically placed biopsy cores must be taken or alternative imaging methods are required to direct TRUS-guided biopsy for improving prostate cancer detection.

  11. Computerized systems for high level information processing and decision making in the field of PSA

    International Nuclear Information System (INIS)

    Kafka, P.; Kunitz, H.

    1990-01-01

    A comprehensive review of Probabilistic Safety Assessment (PSA) related program packages is made. Three fields in methodological succession are covered: plant modeling, data quantification procedures and decision-making support. Packages for fault tree construction and minimal cut sets evaluation are referred to and the performances of three of them: RALLY, ORCHARD and SALP-PC, are discussed and compared. Notions on the raw data sources are presented and the Nuclear Computerized Library for Assessing Reactor Reliability (NUCLARR) is given as an example for data base management system generating PSA data. Aggregated risk models for support in safety assessment, plant operation and accident management (SARA, ESSM, PRISIM) are cited. Examples of systems supporting 'living PSA' (SAIS, SUPER-NET, LESSEPS 1300, NUPRA, SPSA) are given. The concluding remarks outline the state-of-the-art developments of computerized systems for reliability analyses. 1 fig., 1 tab., 51 refs. (R.Ts)

  12. Prostate Health Index (Phi) and Prostate Cancer Antigen 3 (PCA3) significantly improve prostate cancer detection at initial biopsy in a total PSA range of 2-10 ng/ml.

    Science.gov (United States)

    Ferro, Matteo; Bruzzese, Dario; Perdonà, Sisto; Marino, Ada; Mazzarella, Claudia; Perruolo, Giuseppe; D'Esposito, Vittoria; Cosimato, Vincenzo; Buonerba, Carlo; Di Lorenzo, Giuseppe; Musi, Gennaro; De Cobelli, Ottavio; Chun, Felix K; Terracciano, Daniela

    2013-01-01

    Many efforts to reduce prostate specific antigen (PSA) overdiagnosis and overtreatment have been made. To this aim, Prostate Health Index (Phi) and Prostate Cancer Antigen 3 (PCA3) have been proposed as new more specific biomarkers. We evaluated the ability of phi and PCA3 to identify prostate cancer (PCa) at initial prostate biopsy in men with total PSA range of 2-10 ng/ml. The performance of phi and PCA3 were evaluated in 300 patients undergoing first prostate biopsy. ROC curve analyses tested the accuracy (AUC) of phi and PCA3 in predicting PCa. Decision curve analyses (DCA) were used to compare the clinical benefit of the two biomarkers. We found that the AUC value of phi (0.77) was comparable to those of %p2PSA (0.76) and PCA3 (0.73) with no significant differences in pairwise comparison (%p2PSA vs phi p = 0.673, %p2PSA vs. PCA3 p = 0.417 and phi vs. PCA3 p = 0.247). These three biomarkers significantly outperformed fPSA (AUC = 0.60), % fPSA (AUC = 0.62) and p2PSA (AUC = 0.63). At DCA, phi and PCA3 exhibited a very close net benefit profile until the threshold probability of 25%, then phi index showed higher net benefit than PCA3. Multivariable analysis showed that the addition of phi and PCA3 to the base multivariable model (age, PSA, %fPSA, DRE, prostate volume) increased predictive accuracy, whereas no model improved single biomarker performance. Finally we showed that subjects with active surveillance (AS) compatible cancer had significantly lower phi and PCA3 values (pphi and PCA3 comparably increase the accuracy in predicting the presence of PCa in total PSA range 2-10 ng/ml at initial biopsy, outperforming currently used %fPSA.

  13. Summary report of already existing guidance on the implementation of External Hazards in extended Level 1 PSA

    International Nuclear Information System (INIS)

    Klug, J.; Kumar, M.; Prochaska, J.; Brac, P.; Vasseur, D.; Brinkman, H.; Kahia, S.; Nitoi, Mirela; Apostol, M.; Georgescu, G.; Volkanovski, Andrija; Mustoe, J.; Alzbutas, R.; La Rovere, S.

    2015-08-01

    The report provides a summary of already existing guidance on the implementation of external hazards in extended level 1 PSA. It summarized the lessons learnt from existing standards, existing gaps and possibility for future development within the work-package WP22 'How to introduce hazards in L1 PSA and all possibilities of events combinations'. The report is focused on the four following areas, for several hazards: 1) Impact on the SSCs modelled in L1 PSA event trees; 2) Impact on Human Reliability Assessment modelling in L1 PSA; 3) Site impact modelling in L1 PSA event trees; 4) Link between external initiating events of PSA and NPP design basis conditions. During the review of existing guidance, it appeared that many of the references form a suitable basis to introduce external hazards in L1 PSA including event combination. Available guidelines provide usable recommendations to evaluate failure probabilities of SSCs depending on the influence of single hazard or events combination. The most detailed guidelines are devoted to the seismic events and fires. Even if these guidelines deal only with single event impact, they can be also used for combined events purpose to evaluate particular effects induced by analyzed external hazards. Guidelines provide general systematic framework how to determine the scope of SSCs for extended PSA and failure modes (develop an extended list of components). In general available guidelines provide detailed framework for analysis of seismic event. The other external hazards are not always covered so deeply. This is probably caused by specific site nature of these hazards like external floods, fires etc. In case of HRA, more detailed information and HRA models are available for seismic events or fire events. For the other external hazards, the literature with regard to HRA is not well developed. The PSA for external hazards should take account the potential for human response to be affected by the external event. More realistic Human

  14. Research on the improvement of nuclear safety -Development of level 2 PSA technology-

    Energy Technology Data Exchange (ETDEWEB)

    Jin, Yung Hoh; Park, Soo Yong; Kim, Si Dal; Song, Yong Man; An, Kwang Il [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1995-07-01

    The objective of this project is the development of the computer code system for level 2 probabilistic safety assessment (PSA) of nuclear power plants. The scope of the project can be divided into three areas. The first area is to develop the computer code (CONPAS) which can quantify the accident progression event trees. CONPAS beta version has been developed this year and it is comprised of two modules: (1) EDITOR for generating the event tree logic diagrams and (2) QUANTIFICATION for event tree quantification and for additional use of the calculated results. Comparing with the existing computer code, the present code provides a flexible code reusability and user interface, convenient edition of logic diagram, data operation, and systematic quantification of the results. The methodology development of containment structural analysis is the second area. Over twenty large dry PWR containments, the database for containment failure mode and pressure has been constructed and the simplified fragility model has been proposed to calculate the containment failure probability. They will be used as an important input not only in the containment analysis but also in the source term analysis. The last one is to develop the source term analysis methodology which will be used to characterize the source term release for various accidents. One generic parametric equation for PWR and BWR has been composed and parametric database of 6 nuclear plants (4 PWR plants and 2 BWR plants) has been established whose characteristics is then analyzed through the comparison of parameter and data difference among plants. In addition, the characteristics of parameters themselves have been also investigated and the complemental idea of the parametric data base has been briefly suggested. 50 figs, 43 tabs, 50 refs. (Author).

  15. Research on the improvement of nuclear safety -Development of level 2 PSA technology-

    International Nuclear Information System (INIS)

    Jin, Yung Hoh; Park, Soo Yong; Kim, Si Dal; Song, Yong Man; An, Kwang Il

    1995-07-01

    The objective of this project is the development of the computer code system for level 2 probabilistic safety assessment (PSA) of nuclear power plants. The scope of the project can be divided into three areas. The first area is to develop the computer code (CONPAS) which can quantify the accident progression event trees. CONPAS beta version has been developed this year and it is comprised of two modules: (1) EDITOR for generating the event tree logic diagrams and (2) QUANTIFICATION for event tree quantification and for additional use of the calculated results. Comparing with the existing computer code, the present code provides a flexible code reusability and user interface, convenient edition of logic diagram, data operation, and systematic quantification of the results. The methodology development of containment structural analysis is the second area. Over twenty large dry PWR containments, the database for containment failure mode and pressure has been constructed and the simplified fragility model has been proposed to calculate the containment failure probability. They will be used as an important input not only in the containment analysis but also in the source term analysis. The last one is to develop the source term analysis methodology which will be used to characterize the source term release for various accidents. One generic parametric equation for PWR and BWR has been composed and parametric database of 6 nuclear plants (4 PWR plants and 2 BWR plants) has been established whose characteristics is then analyzed through the comparison of parameter and data difference among plants. In addition, the characteristics of parameters themselves have been also investigated and the complemental idea of the parametric data base has been briefly suggested. 50 figs, 43 tabs, 50 refs. (Author)

  16. Serum complexed and free prostate-specific antigen (PSA) for the diagnosis of the polycystic ovarian syndrome (PCOS).

    Science.gov (United States)

    Diamandis, Eleftherios P; Stanczyk, Frank Z; Wheeler, Sarah; Mathew, Anu; Stengelin, Martin; Nikolenko, Galina; Glezer, Eli N; Brown, Marshall D; Zheng, Yingye; Chen, Yen-Hao; Wu, Hsiao-Li; Azziz, Ricardo

    2017-10-26

    Polycystic ovarian syndrome (PCOS) is a common cause of reproductive and metabolic dysfunction. We hypothesized that serum prostate-specific antigen (PSA) may constitute a new biomarker for hyperandrogenism in PCOS. We conducted a cross-sectional study of 45 women with PCOS and 40 controls. Serum from these women was analyzed for androgenic steroids and for complexed PSA (cPSA) and free PSA (fPSA) with a novel fifth- generation assay with a sensitivity of ~10 fg/mL for cPSA and 140 fg/mL for fPSA. cPSA and fPSA levels were about three times higher in PCOS compared to controls. However, in PCOS, cPSA and fPSA did not differ according to waist-to-hip ratio, Ferriman-Gallwey score, or degree of hyperandrogenemia or oligo-ovulation. In PCOS and control women, serum cPSA and fPSA levels were highly correlated with each other, and with free and total testosterone levels, but not with other hormones. Adjusting for age, body mass index (BMI) and race, cPSA was significantly associated with PCOS, with an odds ratio (OR) of 5.67 (95% confidence interval [CI]: 1.86, 22.0). The OR of PCOS for fPSA was 7.04 (95% CI: 1.65, 40.4). A multivariate model that included age, BMI, race and cPSA yielded an area-under-the-receiver-operating-characteristic curve of 0.89. Serum cPSA and fPSA are novel biomarkers for hyperandrogenism in PCOS and may have value for disease diagnosis.

  17. Advancement of the methodology for automated integration of external hazards into level 1 PSA modeling. Technical report; Weiterentwicklung der Methodik zur automatisierten Integration uebergreifender Einwirkungen in PSA-Modelle der Stufe 1. Technischer Fachbericht

    Energy Technology Data Exchange (ETDEWEB)

    Berner, Nadine; Herb, Joachim

    2017-03-15

    In the course of the research and development project RS1539 funded by the German Federal Ministry for Economics and Energy (BMWi) the methodology for the automated integration of hazards in Level 1 PSA models has been enhanced. Thereby, the analysis tool pyRiskRobot provides the methodological framework for mapping a generic spectrum of internal and external hazards onto complex PSA plant models. The reimplementation of the software tool via the programming language python extends the applicability and facilitates the handling of pyRiskRobot in comparison to the previous Ruby-based version RiskRobot. Moreover, the development of functions to perform the topological modelling of fault trees and the probabilistic specification of modified fault tree elements have been continued. Due to the reimplementation and further developments, the tool enables to systematically generate fault trees of varying complexity, to flexibly integrate fault trees in existing PSA models and to automatically duplicate interconnected topologies. Thus, pyRiskRobot allows the efficient and traceable realization of hazard specific, usually laborious modifications of PSA models. In addition, pyRiskRobot has been extended to serve as a functional interface between the data compilations comprising the potential influences of hazards on PSA relevant components and the data base of a PSA plant model. Based on this conceptual design, additional analyses of the data can be carried out prior to the integration within the PSA model topology. The reimplemented functionalities of pyRiskRobot have been validated with respect to reference applications, such as the modelling of an internal fire scenario, against the previous version RiskRobot. The existing method collection for the automated modification of fault tree topologies has been extended based on the requirements for further applications, among others the modelling of an external flooding scenario. The deduced hazard specific modelling approaches

  18. 68Ga-PSMA PET/CT for the detection of bone metastasis in recurrent prostate cancer and a PSA level <2 ng/ml

    DEFF Research Database (Denmark)

    Petersen, Lars J; Nielsen, Julie B; Dettmann, Katja

    2017-01-01

    /computed tomography ((68)Ga-PSMA PET/CT) is a novel and promising method for imaging in prostate cancer. The present study reports two cases of patients with prostate cancer with biochemical recurrence, with evidence of bone metastases on (68)Ga-PSMA PET/CT images and low prostate specific antigen PSA levels (.../ml) and PSA doubling time >6 months. The bone metastases were verified by supplementary imaging with (18)F-sodium fluoride PET/CT and magnetic resonance imaging as well as biochemical responses to androgen deprivation therapy. Therefore, (68)Ga-PSMA PET/CT is promising for the restaging of patients...... with prostate cancer with biochemical recurrence, including patients with low PSA levels and low PSA kinetics....

  19. Post-reconstruction full power and shut down level 2 PSA study for Unit 1 of Bohunice V1 NPP

    International Nuclear Information System (INIS)

    Kovacs, Z.

    2003-01-01

    The level 2 PSA model of the J. Bohunice V1 NPP was developed in the RISK SPECTRUM Professional code with the following objectives: to identify the ways in which radioactive releases from the plant can occur following the core damage; to calculate the magnitudes and frequency of the release; to provide insights into the plant behaviour during a severe accident; to provide a framework for understanding containment failure modes; the impact of the phenomena that could occur during and following core damage and have the potential to challenge the integrity of the confinement; to support the severe accident management and development of SAMGs. The magnitudes of release categories are calculated using: the MAAP4/VVER for reactor operation and shutdown mode with closed reactor vessel and the MELCOR code for shutdown mode with open reactor vessel. In this paper an overview of the Level 2 PSA methodology; description of the confinement; the interface between the level 1 and 2 PSA and accident progression analyses are presented. An evaluation of the confinement failure modes and construction of the confinement event trees as well as definition of release categories, source term analysis and sensitivity analyses are also discussed. The presented results indicate that: 1)for the full power operation - there is an 25% probability that the confinement will successfully maintain its integrity and prevent an uncontrolled fission product release; the most likely mode of release from the confinement is a confinement bypass after SGTM with conditional probability of 30%; the conditional probability for the confinement isolation failure probability without spray is 5%, for early confinement failure at the vessel failure is 4%, for other categories 1% or less; 2) for the shutdown operating modes - the shutdown risk is high for the open reactor vessel and open confinement; important severe accident sequences exists for release categories: RC5.1, RC5.2 and RC6.2

  20. Analysis of convergence of uncertainty and important factors affecting uncertainty in level 1 PSA for pressurized water reactors

    International Nuclear Information System (INIS)

    Shimada, Yoshio

    2002-01-01

    We analyzed how the convergence of mean core damage frequency (CDF) depends on the number of minimal cut sets, the sampling method and the random seed, using level 1 PSA models for Surry 1 and a Japanese 4 loop PWR plant. As a result, the followings were clarified: the good convergence efficiency of the latin hypercube sampling (LHS), the relationship between number of minimal cut sets and mean CDF, as well as the standard deviation and the easy method of judgment for mean CDF convergence. In addition, it was seen that the relationship between the number of probability variables (i.e. the number of basic events) and the number of samplings needed to converge for mean CDF. Analysis of important factors affecting uncertainty was also performed. As a result, it was found that the initiating events (especially loss of coolant accidents) were the dominant important factors. Finally, comparisons were made for the 95% confidence interval of the calculated results from the operating experience of the worldwide nuclear power plants with (1) the mean core damage frequency by PSA for 108 US plants and 51 Japanese plants and (2) the 95% confidence interval of the US and the Japanese Plant PSA model used in this research. As a result, it was clarified that the mean core damage frequency of almost all US pressurized and boiling light water reactors in the US was in the 90% confidence interval calculated from the operating experience of the nuclear power plants (PWRs and BWRs) in the world, but that of those reactors in Japan was smaller then that level. (author)

  1. Analysis of convergence of uncertainty and important factors affecting uncertainty in level 1 PSA for pressurized water reactors

    Energy Technology Data Exchange (ETDEWEB)

    Shimada, Yoshio [Inst. of Nuclear Safety System Inc., Mihama, Fukui (Japan)

    2002-09-01

    We analyzed how the convergence of mean core damage frequency (CDF) depends on the number of minimal cut sets, the sampling method and the random seed, using level 1 PSA models for Surry 1 and a Japanese 4 loop PWR plant. As a result, the followings were clarified: the good convergence efficiency of the latin hypercube sampling (LHS), the relationship between number of minimal cut sets and mean CDF, as well as the standard deviation and the easy method of judgment for mean CDF convergence. In addition, it was seen that the relationship between the number of probability variables (i.e. the number of basic events) and the number of samplings needed to converge for mean CDF. Analysis of important factors affecting uncertainty was also performed. As a result, it was found that the initiating events (especially loss of coolant accidents) were the dominant important factors. Finally, comparisons were made for the 95% confidence interval of the calculated results from the operating experience of the worldwide nuclear power plants with (1) the mean core damage frequency by PSA for 108 US plants and 51 Japanese plants and (2) the 95% confidence interval of the US and the Japanese Plant PSA model used in this research. As a result, it was clarified that the mean core damage frequency of almost all US pressurized and boiling light water reactors in the US was in the 90% confidence interval calculated from the operating experience of the nuclear power plants (PWRs and BWRs) in the world, but that of those reactors in Japan was smaller then that level. (author)

  2. PSA kinetics after prostate brachytherapy: PSA bounce phenomenon and its implications for PSA doubling time

    International Nuclear Information System (INIS)

    Ciezki, Jay P.; Reddy, Chandana A.; Garcia, Jorge; Angermeier, Kenneth; Ulchaker, James; Mahadevan, Arul; Chehade, Nabil; Altman, Andrew; Klein, Eric A.

    2006-01-01

    using the bF3 definition and 8.8 months using the bFn+2 definition. However, a significant difference was found in the time to the first rise in PSA after PI for patients with a PSA bounce vs. patients with bF. The median time to the first rise in PSA after nadir for those with a PSA bounce was 15.1 months vs. 30.0 months using the bF3 definition (p = 0.001) and 22.3 months using the bFn+2 definition (p = 0.013). Conclusion: Patients experiencing a PSA bounce are more likely to be younger and will have a better bRFS. The PSADT cannot differentiate a PSA bounce from bF. The time to the initial PSA rise after nadir is an excellent discriminator of bF from PSA bounce. The time of the PSA rise after nadir occurs far sooner for a PSA bounce than for bF. This factor should be considered when assessing a patient with a rising PSA level after PI before a patient is administered salvage therapy

  3. Evaluation of the Impact That PARs Have on the Hydrogen Risk in the Reactor Containment: Methodology and Application to PSA Level 2

    Directory of Open Access Journals (Sweden)

    Ahmed Bentaib

    2010-01-01

    Full Text Available This paper presents a methodology and its application to a Level 2 Probabilistic Safety Assessment (PSA-2, to evaluate the impact of the Passive Autocatalytic Recombiners (PARs on the hydrogen risk in the reactor containment in case of a severe accident. Among the whole set of accidental scenarios calculated in the framework of the PSA-2, nine have been selected as representative in terms of the in-vessel hydrogen production rate and in-vessel total produced hydrogen mass. Five complementary scenarios have been added as representative of the core reflooding situations. For this set of selected scenarios the evolution of the conditions in the containment (i.e., pressure, temperature, and composition during the in-vessel phase of the accident has been evaluated by means of a lumped parameter approach. The use of spray systems in the containment has also been considered as well as the presence of recombiners. Moreover, the ignition by recombiners of the flammable atmosphere has been considered.

  4. Failure to Achieve a PSA Level ≤1 ng/mL After Neoadjuvant LHRHA Therapy Predicts for Lower Biochemical Control Rate and Overall Survival in Localized Prostate Cancer Treated With Radiotherapy

    International Nuclear Information System (INIS)

    Mitchell, Darren M.; McAleese, Jonathan; Park, Richard M.; Stewart, David P.; Stranex, Stephen; Eakin, Ruth L.; Houston, Russell F.; O'Sullivan, Joe M.

    2007-01-01

    Purpose: To investigate whether failure to suppress the prostate-specific antigen (PSA) level to ≤1 ng/mL after ≥2 months of neoadjuvant luteinizing hormone-releasing hormone agonist therapy in patients scheduled to undergo external beam radiotherapy for localized prostate carcinoma is associated with reduced biochemical failure-free survival. Methods and Materials: A retrospective case note review of consecutive patients with intermediate- or high-risk localized prostate cancer treated between January 2001 and December 2002 with neoadjuvant hormonal deprivation therapy, followed by concurrent hormonal therapy and radiotherapy was performed. Patient data were divided for analysis according to whether the PSA level in Week 1 of radiotherapy was ≤1.0 ng/mL. Biochemical failure was determined using the American Society for Therapeutic Radiology and Oncology (Phoenix) definition. Results: A total of 119 patients were identified. The PSA level after neoadjuvant hormonal deprivation therapy was ≤1 ng/mL in 67 patients and >1 ng/mL in 52. At a median follow-up of 49 months, the 4-year actuarial biochemical failure-free survival rate was 84% vs. 60% (p = 0.0016) in favor of the patients with a PSA level after neoadjuvant hormonal deprivation therapy of ≤1 ng/mL. The overall survival rate was 94% vs. 77.5% (p = 0.0045), and the disease-specific survival rate at 4 years was 98.5% vs. 82.5%. Conclusions: The results of our study have shown that patients with a PSA level >1 ng/mL at the beginning of external beam radiotherapy after ≥2 months of neoadjuvant luteinizing hormone-releasing hormone agonist therapy have a significantly greater rate of biochemical failure and lower survival rate compared with those with a PSA level of ≤1 ng/mL. Patients without adequate PSA suppression should be considered a higher risk group and considered for dose escalation or the use of novel treatments

  5. Combination of signal intensity measurements of lesions in the peripheral zone of prostate with MRI and serum PSA level for differentiating benign disease from prostate cancer

    Energy Technology Data Exchange (ETDEWEB)

    Engelhard, K.; Kreckel, M. [Department of Radiology, Martha-Maria Hospital Nuernberg (Germany); Hollenbach, H.P.; Deimling, M. [Siemens Medical Engineering Group, Erlangen (Germany); Riedl, C. [Dept. of Urology, University of Erlangen-Nuernberg, Erlangen (Germany)

    2000-12-01

    The aim of this study was to predict the benign or malignant nature of a prostatic lesion by defining a threshold value of signal intensity ratio and a limiting value of serum prostate-specific antigen (PSA) in patients with elevated PSA level. Twenty-six patients with elevated PSA level and no hypoechogenic lesions at endosonography underwent MR imaging using an endorectal body phased-array coil at 1.5 T (Siemens Magnetom Symphony). A T2-weighted turbo-spin-echo (TSE) pulse sequence was applied in a transverse orientation. Two radiologists evaluated the images. In the presence of a pathological finding they defined regions of interest (ROI) in the suspicious pathological area of the peripheral zone and in muscle for reference. The quotient of the two ROIs was calculated and then correlated with the actual PSA level. Diagnosis was confirmed by prostate biopsy. Ten of 12 patients with quotients smaller than 4 showed cancer at histology. Nine of 12 men with cancer proven by biopsy had PSA levels higher than 10 ng/ml. A significant difference (p < 0.001) was found between the quotients of cancer and quotients of chronic prostatitis, fibrosis, or glandular atrophy. The accuracy of tumor differentiation of the method was 77 %. Measurement of signal intensity quotients in the peripheral zone of the prostate in combination with knowledge of defined limits of PSA levels the technique could be helpful in detecting additional cancer areas for prostate biopsy. False-negative tumor results of standard sextant biopsy can be reduced. In men with high PSA values the method has a role in differentiating between patients who require prostate biopsy and those of clinical observation. (orig.)

  6. Can delayed time to referral to a tertiary level urologist with an abnormal PSA level affect subsequent Gleason grade in the opportunistically screened population?

    LENUS (Irish Health Repository)

    O'Kelly, Fardod

    2013-09-01

    There is growing conflict in the literature describing the effect of delayed treatment on outcomes following radical prostatectomy. There is also evidence to suggest progression of low-risk prostate cancer to develop higher grades and volumes of prostate cancer during active surveillance. It is unknown as to what affect a delay in referral of those men with abnormal screened-PSA levels have on subsequent Gleason grade.

  7. Methods and results of a PSA level 2 for a German BWR of the 900 MWe class

    International Nuclear Information System (INIS)

    Loffler, H.; Sonnenkalb, M.

    2006-01-01

    On behalf of the federal Ministry for Environment, Nature Conservation and Reactor Safety (BMU) GRS has performed a PSA level 2 for a BWR type 69 NPP of the 900 MWe class, equipped with a N 2 inerted steel containment and a pressure suppression system. Integral deterministic accident analyses have been performed with the computer code MELCOR 1.8.5. Additional analyses have been done for those events and phenomena which are not or not sufficiently covered by MELCOR. The probabilistic event tree analysis begins with the core damage states received from PSA level 1, and it ends with the definition of release categories and the determination of their frequencies. Uncertainties about the frequency of core damage states and about events during the accident progression are taken into account by means of Monte Carlo simulations. If there is a core damage state there is a high probability (>50 %) for a very high and rapid release of radionuclides into the environment. This high conditional probability is due to the very low probability to retain a partly destroyed core inside the reactor pressure vessel (RPV) and because the containment almost certainly fails at the bottom of the control rod drives room after melt release from the failed RPV. (authors)

  8. PSA-alpha-2-macroglobulin complex is enzymatically active in the serum of patients with advanced prostate cancer and can degrade circulating peptide hormones.

    Science.gov (United States)

    Kostova, Maya B; Brennen, William Nathaniel; Lopez, David; Anthony, Lizamma; Wang, Hao; Platz, Elizabeth; Denmeade, Samuel R

    2018-08-01

    Prostate cancer cells produce high levels of the serine protease Prostate-Specific Antigen (PSA). PSA is enzymatically active in the tumor microenvironment but is presumed to be enzymatically inactive in the blood due to complex formation with serum protease inhibitors α-1-antichymotrypsin and α-2-macroglobulin (A2M). PSA-A2M complexes cannot be measured by standard ELISA assays and are also rapidly cleared from the circulation. Thus the exact magnitude of PSA production by prostate cancer cells is not easily measured. The PSA complexed to A2M is unable to cleave proteins but maintains the ability to cleave small peptide substrates. Thus, in advanced prostate cancer, sufficient PSA-A2M may be in circulation to effect total A2M levels, levels of cytokines bound to A2M and hydrolyze small circulating peptide hormones. Total A2M levels in men with advanced prostate cancer and PSA levels above 1000 ng/mL were measured by ELISA and compared to controls. Additional ELISA assays were used to measure levels of IL-6 and TGF-beta which can bind to A2M. The ability of PSA-A2M complexes to hydrolyze protein and peptide substrates was analyzed ± PSA inhibitor. Enzymatic activity of PSA-A2M in serum of men with high PSA levels was also assayed. Serum A2M levels are inversely correlated with PSA levels in men with advanced prostate cancer. Il-6 Levels are significantly elevated in men with PSA >1000 ng/mL compared to controls with PSA PSA-A2M complex in serum of men with PSA levels >1000 ng/mL can hydrolyze small fluorescently labeled peptide substrates but not large proteins that are PSA substrates. PSA can hydrolyze small peptide hormones like PTHrP and osteocalcin. PSA complexed to A2M retains the ability to degrade PTHrP. In advanced prostate cancer with PSA levels >1000 ng/mL, sufficient PSA-A2M is present in circulation to produce enzymatic activity against circulating small peptide hormones. Sufficient PSA is produced in advanced prostate cancer to alter

  9. PSA methodology

    Energy Technology Data Exchange (ETDEWEB)

    Magne, L

    1997-12-31

    The purpose of this text is first to ask a certain number of questions on the methods related to PSAs. Notably we will explore the positioning of the French methodological approach - as applied in the EPS 1300{sup 1} and EPS 900{sup 2} PSAs - compared to other approaches (Part One). This reflection leads to more general reflection: what contents, for what PSA? This is why, in Part Two, we will try to offer a framework for definition of the criteria a PSA should satisfy to meet the clearly identified needs. Finally, Part Three will quickly summarize the questions approached in the first two parts, as an introduction to the debate. 15 refs.

  10. PSA methodology

    International Nuclear Information System (INIS)

    Magne, L.

    1996-01-01

    The purpose of this text is first to ask a certain number of questions on the methods related to PSAs. Notably we will explore the positioning of the French methodological approach - as applied in the EPS 1300 1 and EPS 900 2 PSAs - compared to other approaches (Part One). This reflection leads to more general reflection: what contents, for what PSA? This is why, in Part Two, we will try to offer a framework for definition of the criteria a PSA should satisfy to meet the clearly identified needs. Finally, Part Three will quickly summarize the questions approached in the first two parts, as an introduction to the debate. 15 refs

  11. Prostate Health Index (Phi) and Prostate Cancer Antigen 3 (PCA3) Significantly Improve Prostate Cancer Detection at Initial Biopsy in a Total PSA Range of 2–10 ng/ml

    Science.gov (United States)

    Perdonà, Sisto; Marino, Ada; Mazzarella, Claudia; Perruolo, Giuseppe; D’Esposito, Vittoria; Cosimato, Vincenzo; Buonerba, Carlo; Di Lorenzo, Giuseppe; Musi, Gennaro; De Cobelli, Ottavio; Chun, Felix K.; Terracciano, Daniela

    2013-01-01

    Many efforts to reduce prostate specific antigen (PSA) overdiagnosis and overtreatment have been made. To this aim, Prostate Health Index (Phi) and Prostate Cancer Antigen 3 (PCA3) have been proposed as new more specific biomarkers. We evaluated the ability of phi and PCA3 to identify prostate cancer (PCa) at initial prostate biopsy in men with total PSA range of 2–10 ng/ml. The performance of phi and PCA3 were evaluated in 300 patients undergoing first prostate biopsy. ROC curve analyses tested the accuracy (AUC) of phi and PCA3 in predicting PCa. Decision curve analyses (DCA) were used to compare the clinical benefit of the two biomarkers. We found that the AUC value of phi (0.77) was comparable to those of %p2PSA (0.76) and PCA3 (0.73) with no significant differences in pairwise comparison (%p2PSA vs phi p = 0.673, %p2PSA vs. PCA3 p = 0.417 and phi vs. PCA3 p = 0.247). These three biomarkers significantly outperformed fPSA (AUC = 0.60), % fPSA (AUC = 0.62) and p2PSA (AUC = 0.63). At DCA, phi and PCA3 exhibited a very close net benefit profile until the threshold probability of 25%, then phi index showed higher net benefit than PCA3. Multivariable analysis showed that the addition of phi and PCA3 to the base multivariable model (age, PSA, %fPSA, DRE, prostate volume) increased predictive accuracy, whereas no model improved single biomarker performance. Finally we showed that subjects with active surveillance (AS) compatible cancer had significantly lower phi and PCA3 values (p<0.001 and p = 0.01, respectively). In conclusion, both phi and PCA3 comparably increase the accuracy in predicting the presence of PCa in total PSA range 2–10 ng/ml at initial biopsy, outperforming currently used %fPSA. PMID:23861782

  12. Prostate Health Index (Phi and Prostate Cancer Antigen 3 (PCA3 significantly improve prostate cancer detection at initial biopsy in a total PSA range of 2-10 ng/ml.

    Directory of Open Access Journals (Sweden)

    Matteo Ferro

    Full Text Available Many efforts to reduce prostate specific antigen (PSA overdiagnosis and overtreatment have been made. To this aim, Prostate Health Index (Phi and Prostate Cancer Antigen 3 (PCA3 have been proposed as new more specific biomarkers. We evaluated the ability of phi and PCA3 to identify prostate cancer (PCa at initial prostate biopsy in men with total PSA range of 2-10 ng/ml. The performance of phi and PCA3 were evaluated in 300 patients undergoing first prostate biopsy. ROC curve analyses tested the accuracy (AUC of phi and PCA3 in predicting PCa. Decision curve analyses (DCA were used to compare the clinical benefit of the two biomarkers. We found that the AUC value of phi (0.77 was comparable to those of %p2PSA (0.76 and PCA3 (0.73 with no significant differences in pairwise comparison (%p2PSA vs phi p = 0.673, %p2PSA vs. PCA3 p = 0.417 and phi vs. PCA3 p = 0.247. These three biomarkers significantly outperformed fPSA (AUC = 0.60, % fPSA (AUC = 0.62 and p2PSA (AUC = 0.63. At DCA, phi and PCA3 exhibited a very close net benefit profile until the threshold probability of 25%, then phi index showed higher net benefit than PCA3. Multivariable analysis showed that the addition of phi and PCA3 to the base multivariable model (age, PSA, %fPSA, DRE, prostate volume increased predictive accuracy, whereas no model improved single biomarker performance. Finally we showed that subjects with active surveillance (AS compatible cancer had significantly lower phi and PCA3 values (p<0.001 and p = 0.01, respectively. In conclusion, both phi and PCA3 comparably increase the accuracy in predicting the presence of PCa in total PSA range 2-10 ng/ml at initial biopsy, outperforming currently used %fPSA.

  13. Time to PSA rise differentiates the PSA bounce after HDR and LDR brachytherapy of prostate cancer.

    Science.gov (United States)

    Burchardt, Wojciech; Skowronek, Janusz

    2018-02-01

    To investigate the differences in prostate-specific antigen (PSA) bounce (PB) after high-dose-rate (HDR-BT) or low-dose-rate (LDR-BT) brachytherapy alone in prostate cancer patients. Ninety-four patients with localized prostate cancer (T1-T2cN0), age ranged 50-81 years, were treated with brachytherapy alone between 2008 and 2010. Patients were diagnosed with adenocarcinoma, Gleason score ≤ 7. The LDR-BT total dose was 144-145 Gy, in HDR-BT - 3 fractions of 10.5 or 15 Gy. The initial PSA level (iPSA) was assessed before treatment, then PSA was rated every 3 months over the first 2 years, and every 6 months during the next 3 years. Median follow-up was 3.0 years. Mean iPSA was 7.8 ng/ml. In 58 cases, PSA decreased gradually without PB or biochemical failure (BF). In 24% of patients, PB was observed. In 23 cases (24%), PB was observed using 0.2 ng/ml definition; in 10 cases (11%), BF was diagnosed using nadir + 2 ng/ml definition. The HDR-BT and LDR-BT techniques were not associated with higher level of PB (26 vs. 22%, p = 0.497). Time to the first PSA rise finished with PB was significantly shorter after HDR-BT then after LDR-BT (median, 10.5 vs. 18.0 months) during follow-up. Predictors for PB were observed only after HDR-BT. Androgen deprivation therapy (ADT) and higher Gleason score decreased the risk of PB (HR = 0.11, p = 0.03; HR = 0.51, p = 0.01). The higher PSA nadir and longer time to PSA nadir increased the risk of PB (HR 3.46, p = 0.02; HR 1.04, p = 0.04). There was no predictors for PB after LDR-BT. HDR-BT and LDR-BT for low and intermediate risk prostate cancer had similar PB rate. The PB occurred earlier after HDR-BT than after LDR-BT. ADT and higher Gleason score decreased, and higher PSA nadir and longer time to PSA nadir increased the risk of PB after HDR-BT.

  14. Regulatory aspects of the use of PSA to evaluate technical specifications

    International Nuclear Information System (INIS)

    Rumpf, J.

    1991-01-01

    Based on experiences gained in PSA activities the regulatory body of the GDR initiated a programme to investigate the feasibility of using PSA for the evaluation of technical specifications. This programme is just under work. In addition, to improve PSA, the GDR takes part in a programme which is aimed at performing plant specific level 1, PSA as well as and which enables operating organizations to carry out PSA on their own. The most important of some preliminary general findings presented in this paper are: - Technical specifications form a well established envelope of operational conditions and procedures. A total re-evaluation is not considered necessary; Probabilistic evaluation of technical specifications should be an integrated part of PSA activities (at least level 1). Single assessment is not considered reasonable; Probabilistic evaluation of technical specifications has to be based on plant specific information and realistic accident sequence calculations; Up to now no quantitative probabilistic criteria for technical specifications have been established. (author)

  15. Clinical significance of combined determination of serum levels of free prostate specific antigen (fPSA) and insulin-like growth factor-1 (IGF-1) in patients with prostatic cancer

    International Nuclear Information System (INIS)

    Wang Xiaolong; Chen Baixun; Chen Yue

    2004-01-01

    Objective: To explore the clinical significance of combined determination of serum levels of fPSA and IGF-1 in patients with prostatic cancer. Methods: Serum levels of fPSA (with chemiluminescence) and IGF-1 (with IRMA) were measured in 48 patients with prostatic cancer, 63 patients with benign prostate hyperplasia and 38 controls. Results: Serum levels of fPSA and IGF-1 in the 111 patients were significantly higher than those in controls (P<0.05). The positive rate for prostatic cancer detection with fPSA, IGF-1 and fPSA combined with IGF-1 was 83.3%, 79.2% and 95.8% respectively. Conclusion: Combined measurement of fPSA and IGF-1 was most preferable for screening prostatic cancer

  16. Complement of existing ASAMPSA2 guidance for Level 2 PSA for shutdown states of reactors, Spent Fuel Pool and recent R and D results

    International Nuclear Information System (INIS)

    Kumar, M.; Olsson, A.; Loeffler, H.; Morandi, S.; Gumenyuk, D.; Dejardin, P.; Yu, S.; Jan, P.; Kubicek, J.; Serrano, C.; Raimond, E.; Dirksen, G.; Ivanov, I.; Groudev, P.; Kowal, K.; Prosek, Andrej; Nitoi, M.; Vitazkova, J.; Hirata, K.; Burgazzi, L.

    2016-01-01

    This report can be considered as an addendum to the existing ASAMPSA2 guidance for Level 2 PSA. It provides complementary guidance for Level 2 PSA for accident in the NPP shutdown states and on spent fuel pool and comments on the importance of these accidents on nuclear safety. It includes also information on recent research and development useful for Level 2 PSA developments. The conclusions of the ASAMPSA-E end-users survey and of technical meetings of WP10, WP21, WP22, and WP30 at Vienna University in September 2014 which are relevant for Level 2 PSA have been reflected and are taken into account as much as it is possible with the current status of knowledge. For Level 2 PSA in shutdown states, two plant conditions are to be distinguished: - accident sequences with RPV head closed, - accident sequences with RPV head open. When the RPV head is closed, core melt accident phenomena are very similar to the sequences going on in full power mode. Therefore, the large body of guidance which is available for full power mode is basically applicable to shutdown mode with RPV closed as well. When the RPV is open, some of the L2 PSA issues become irrelevant compared to full power mode, while others come into existence. The situation is different for aspects which do not exist or which are less pronounced in sequences with RPV closed. The report also covers containment issues in shutdown states and discusses the applicability of existing guidance, potential gaps and deficiencies and recommendations are provided. For spent fuel pool accidents in Level 2 PSA, a set of issues is identified and addressed. If the spent fuel pool is located inside the containment, the potential release paths to the environment are almost the same as for core melt accidents in the RPV. If the spent fuel pool is located outside the containment, the potential release paths to the environment depend very much on plant specific properties, e.g. ventilation systems, building doors, roof under thermal

  17. Early diagnostic role of PSA combined miR-155 detection in prostate cancer.

    Science.gov (United States)

    Guo, T; Wang, X-X; Fu, H; Tang, Y-C; Meng, B-Q; Chen, C-H

    2018-03-01

    As a kind of malignant tumor in the male genitourinary system, prostate cancer exhibits significantly increased occurrence. Prostate-specific antigen (PSA) expression can be seen in the prostate cancer, prostatitis, and other diseases, therefore, lack of diagnostic specificity. The miR-155 expression is abnormally increased in the tumors. Therefore, this study aims to explore the clinical significance of PSA combined miR-155 detection in the early diagnosis of prostate cancer. A total of 86 patients diagnosed with prostate cancer were enrolled in this study. PSA and miR-155 gene expression in tumor tissue were detected by using Real-time PCR. The serum levels of PSA were measured by using enzyme-linked immunosorbent assay (ELISA). The correlation of PSA and miR-155 expression with age, body mass index (BMI), tumor volume, tumor-node-metastasis (TNM) stage, lymph node metastasis (LNM), and other clinicopathological features were analyzed, respectively. Serum PSA expression and PSA gene in tumor tissue were significantly higher compared to that in adjacent tissues (pPSA gene and protein increased significantly with the clinical stage of TNM and decreased following the increase of grade (pPSA and miR-155 expressions were positively correlated with TNM stage, tumor volume, and LNM, and negatively correlated with grade (pPSA and miR-155 were closely related to the clinicopathological features of prostate cancer. Combined detection is helpful for the early diagnosis of prostate cancer.

  18. PSA applications

    Energy Technology Data Exchange (ETDEWEB)

    Dubreuil Chambardel, A

    1997-12-31

    The IAEA now defines three types of PSA applications: Validation of design and of operation procedures; optimization of plant operation; and regulatory applications. The applications of PSA are manifold: only a few are dealt with here (precursor analysis is dealt with in session 3, topic 4). For each of them, we will do the utmost to demonstrate the main difficulties encountered, EDF`s viewpoint on the matter, and the points remaining to be solved. In what follows, unless explicitly stated otherwise, we have made every effort to represent the different applications as they are practiced by all concerned in the international community, and to describe the inherent difficulties the international community has encountered with these applications with all objectivity. It goes without saying that the comments below are simply those of the ESF department, and are submitted here for discussion by the experts. 13 refs.

  19. PSA applications

    International Nuclear Information System (INIS)

    Dubreuil Chambardel, A.

    1996-01-01

    The IAEA now defines three types of PSA applications: Validation of design and of operation procedures; optimization of plant operation; and regulatory applications. The applications of PSA are manifold: only a few are dealt with here (precursor analysis is dealt with in session 3, topic 4). For each of them, we will do the utmost to demonstrate the main difficulties encountered, EDF's viewpoint on the matter, and the points remaining to be solved. In what follows, unless explicitly stated otherwise, we have made every effort to represent the different applications as they are practiced by all concerned in the international community, and to describe the inherent difficulties the international community has encountered with these applications with all objectivity. It goes without saying that the comments below are simply those of the ESF department, and are submitted here for discussion by the experts. 13 refs

  20. PSA Update Procedures, an Ultimate Need for Living PSA

    International Nuclear Information System (INIS)

    Hegedus, D.

    1998-01-01

    Nuclear facilities by their complex nature, change with time. These changes can be both physical (plant modification, etc.), operational (enhanced procedures, etc.) and organizational. In addition, there are also changes in our understanding of the plant, due to operational experience, data collection, technology enhancements, etc. Therefore, it is imperative that PSA model must be frequently up-dated or modified to reflect these changes. Over the last ten years. these has been a remarkable growth of the use of Probabilistic Safety Assessments (PSAs). The most rapidly growing area of the PSA Applications is their use to support operational decision-making. Many of these applications are characterized by the potential for not only improving the safety level but also for providing guidance on the optimal use of resources and reducing regulatory burden. To enable a wider use of the PSA model as a tool for safety activities it is essential to maintain the model in a controlled state. Moreover, to fulfill requirements for L iving PSA , the PSA model has to be constantly updated and/or monitored to reflect the current plant configuration. It should be noted that the PSA model should not only represent the plant design but should also represent the operational and emergency procedures. To keep the PSA model up-to-date several issues should be clearly defined including: - Responsibility should be divided among the PSA group, - Procedures for implementing changes should be established, and - QA requirements/program should be established to assure documentation and reporting. (author)

  1. PSA - a tool for the nuclear safety

    International Nuclear Information System (INIS)

    Himanen, R.

    1992-01-01

    The PSA-model for BWR-type reactors of Finnish power company, Teollisuuden Voima Oy (TVO) was finished in year 1989. This basic PSA model included all safety systems, normal operating systems and auxiliary systems. Today TVO is working to enlarge the PSA to level 2 (environmental effects, for the fires, for the floodings and the outages). The TVO's experiences has been showed the PSA an useful tool for the developing the safety of BWR's (orig.)

  2. Can Prostate Imaging Reporting and Data System Version 2 reduce unnecessary prostate biopsies in men with PSA levels of 4-10 ng/ml?

    Science.gov (United States)

    Xu, Ning; Wu, Yu-Peng; Chen, Dong-Ning; Ke, Zhi-Bin; Cai, Hai; Wei, Yong; Zheng, Qing-Shui; Huang, Jin-Bei; Li, Xiao-Dong; Xue, Xue-Yi

    2018-05-01

    To explore the value of Prostate Imaging Reporting and Data System Version 2 (PI-RADS v2) for predicting prostate biopsy results in patients with prostate specific antigen (PSA) levels of 4-10 ng/ml. We retrospectively reviewed multi-parameter magnetic resonance images from 528 patients with PSA levels of 4-10 ng/ml who underwent transrectal ultrasound-guided prostate biopsies between May 2015 and May 2017. Among them, 137 were diagnosed with prostate cancer (PCa), and we further subdivided them according to pathological results into the significant PCa (S-PCa) and insignificant significant PCa (Ins-PCa) groups (121 cases were defined by surgical pathological specimen and 16 by biopsy). Age, PSA, percent free PSA, PSA density (PSAD), prostate volume (PV), and PI-RADS score were collected. Logistic regression analysis was performed to determine predictors of pathological results. Receiver operating characteristic curves were constructed to analyze the diagnostic value of PI-RADS v2 in PCa. Multivariate analysis indicated that age, PV, percent free PSA, and PI-RADS score were independent predictors of biopsy findings, while only PI-RADS score was an independent predictor of S-PCa (P PSA, and PI-RADS score were 0.570, 0.430, 0.589 and 0.836, respectively. The area under the curve for diagnosing S-PCa with respect to PI-RADS score was 0.732. A PI-RADS score of 3 was the best cutoff for predicting PCa, and 4 was the best cutoff for predicting S-PCa. Thus, 92.8% of patients with PI-RADS scores of 1-2 would have avoided biopsy, but at the cost of missing 2.2% of the potential PCa cases. Similarly, 83.82% of patients with a PI-RADS score ≤ 3 would have avoided biopsy, but at the cost of missing 3.3% of the potential S-PCa cases. PI-RADS v2 could be used to reduce unnecessary prostate biopsies in patients with PSA levels of 4-10 ng/ml.

  3. PSA-operations synergism for the advanced test reactor shutdown operations PSA

    International Nuclear Information System (INIS)

    Atkinson, S.A.

    1996-01-01

    The Advanced Test Reactor (ATR) Probabilistic Safety Assessment (PSA) for shutdown operations, cask handling, and canal draining is a successful example of the importance of good PSA-operations synergism for achieving a realistic and accepted assessment of the risks and for achieving desired risk reduction and safety improvement in a best and cost-effective manner. The implementation of the agreed-upon upgrades and improvements resulted in the reductions of the estimated mean frequency for core or canal irradiated fuel uncovery events, a total reduction in risk by a factor of nearly 1000 to a very low and acceptable risk level for potentially severe events

  4. A methodology for Level 2 PSA evaluation with consideration of specific features for Low Power Shutdown Probabilistic Safety Assessment

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jae Gab; Seok, Ho [KEPCO-ENC, Yongin (Korea, Republic of)

    2015-05-15

    The primary objective of the Level 2 PSA during Lower Power/Shutdown (LPSD) operation is to provide insights into potential plant vulnerabilities with regard to accident progression. The shutdown risk information can be used to provide the information to develop outage risk management guidelines. The LPSD Level 2 analysis utilizes much of the at-power Level 2 analysis for bounding, conservative treatment of severe accident phenomena. But, for some portions of the analysis including Plant Operational States (POSs), LPSD-specific evaluations such as UPC related to the containment Equipment Hatch (E/H) with 4 bolts, Reactor Coolant System (RCS) Not Intact for severe accident phenomena are desired for realistic evaluation. All POSs are evaluated for their Large Release Frequency (LRF). Some POSs are evaluated conservatively utilizing the at-power models, and other POSs are evaluated in specific analysis. The overall LPSD Level 2 model is evaluated. If the containment E/H and one of the two doors on each of the personal air locks are closed as containment is operable at reduced RCS inventory operation, LRF is expected to be less than 10% of LPSD CDF.

  5. High-Risk Prostate Cancer With Gleason Score 8–10 and PSA Level ≤15 ng/ mL Treated With Permanent Interstitial Brachytherapy

    International Nuclear Information System (INIS)

    Fang, L. Christine; Merrick, Gregory S.; Butler, Wayne M.; Galbreath, Robert W.; Murray, Brian C.; Reed, Joshua L.; Adamovich, Edward; Wallner, Kent E.

    2011-01-01

    Purpose: With widespread prostate-specific antigen (PSA) screening, there has been an increase in men diagnosed with high-risk prostate cancer defined by a Gleason score (GS) ≥8 coupled with a relatively low PSA level. The optimal management of these patients has not been defined. Cause-specific survival (CSS), biochemical progression-free survival (bPFS), and overall survival (OS) were evaluated in brachytherapy patients with a GS ≥8 and a PSA level ≤15 ng/mL with or without androgen-deprivation therapy (ADT). Methods and Materials: From April 1995 to October 2005, 174 patients with GS ≥8 and a PSA level ≤15 ng/mL underwent permanent interstitial brachytherapy. Of the patients, 159 (91%) received supplemental external beam radiation, and 113 (64.9%) received ADT. The median follow-up was 6.6 years. The median postimplant Day 0 minimum percentage of the dose covering 90% of the target volume was 121.1% of prescription dose. Biochemical control was defined as a PSA level ≤0.40 ng/mL after nadir. Multiple parameters were evaluated for impact on survival. Results: Ten-year outcomes for patients without and with ADT were 95.2% and 92.5%, respectively, for CSS (p = 0.562); 86.5% and 92.6%, respectively, for bPFS (p = 0.204); and 75.2% and 66.0%, respectively, for OS (p = 0.179). The median post-treatment PSA level for biochemically controlled patients was <0.02 ng/mL. Multivariate analysis failed to identify any predictors for CSS, whereas bPFS and OS were most closely related to patient age. Conclusions: Patients with GS ≥8 and PSA level ≤15 ng/mL have excellent bPFS and CSS after brachytherapy with supplemental external beam radiotherapy. The use of ADT did not significantly impact bPFS, CSS, or OS.

  6. Evaluation of postradiotherapy PSA patterns and correlation with 10-year disease free survival outcomes for prostate cancer

    International Nuclear Information System (INIS)

    Zelefsky, Michael J.; Ben-Porat, Leah; Chan, Heather M.; Fearn, Paul A.; Venkatraman, Ennapadam S.

    2006-01-01

    Purpose: To describe the prostate-specific antigen (PSA) pattern profiles observed after external beam radiotherapy with and without short-term neoadjuvant androgen deprivation therapy (ST-ADT) and to report the association of established posttreatment PSA patterns with long-term disease-free survival outcomes. Methods and Materials: A total of 1,665 patients were treated with conformal external beam radiotherapy for clinically localized prostate cancer. Of 570 patients who had the requisite >10 consecutive PSA measurements for statistical analysis, 194 patients received a median of 3 months of ADT before radiotherapy and 376 were treated with radiotherapy alone. The median follow up was 103 months. Results: In the group treated with ST-ADT, three distinct postradiotherapy PSA patterns were identified: a stable trend (44%), an increasing trend followed by stabilization of the PSA (25%), and an increasing trend (31%). Among the subgroup that demonstrated a rising and subsequent stabilizing patterns, PSA levels had gradually risen to a median value of 0.9 ng/mL after therapy, stabilized, and remained durably suppressed. The only identified trends among patients treated with external beam radiotherapy without ST-ADT were declining PSA levels followed by stable PSA trends or declining patterns followed by rising levels. Patients whose PSA levels stabilized after an initial rise or those with slowly rising PSA profiles had a lower incidence of distant metastasis compared to those with accelerated rises after therapy. Conclusions: For those treated with external beam radiotherapy in conjunction with ST-ADT, a significant percentage who develop a rising PSA after treatment are expected to manifest subsequent stabilization at plateaued levels of approximately 1.0 ng/mL, which can remain durably suppressed. The likelihood of distant metastasis in these patients is low despite the PSA stabilization at levels 1.0 ng/mL or higher and comparable to outcomes observed for those

  7. Long-distance mountain biking does not disturb the measurement of total, free or complexed prostate-specific antigen in healthy men.

    Science.gov (United States)

    Herrmann, Markus; Scharhag, Jürgen; Sand-Hill, Marga; Kindermann, Wilfried; Herrmann, Wolfgang

    2004-03-01

    Mechanical manipulation of the prostate is a generally accepted interfering factor for the measurement of prostate-specific antigen (PSA). However, only few studies have focused on common daily mechanical manipulations, such as bicycle riding. Furthermore, physical exercise is also supposed to modulate PSA serum concentration. Long-distance mountain biking is an excellent model to study the combined effect of mechanical prostate manipulation by bicycle riding and strenuous endurance exercise on total, free and complexed PSA (tPSA, fPSA, cPSA). We investigated tPSA, fPSA and cPSA in 42 healthy male cyclists (mean age 35+/-6 years) before and after a 120 km off-road mountain bike race. Blood sampling was done before, 15 min and 3 h after the race. Mean race time was 342+/-65 min. All athletes had normal serum levels of tPSA, fPSA or cPSA. None of these parameters was modified by the race. In healthy men the measurement of tPSA, fPSA and cPSA is not disturbed by preceding long distance mountain biking or endurance exercise. Based on the present data, there is no evidence for a recommendation to limit bicycle riding or physical activity before the measurement of tPSA, fPSA or cPSA.

  8. A Study on the Risk Reduction Effect by MLCS (Mid-loop Level Control System) of EUAPR using the Low-Power and Shutdown PSA Result

    International Nuclear Information System (INIS)

    Lee, Keunsung; Choi, Sunmi; Kim, Eden

    2016-01-01

    The EU-APR design has been developed in order to expand and diversify the global nuclear power market of APR1400. For the improvement of shutdown risk for the EUAPR, the mid-loop level control system (MLCS) is considered during mid-loop operation for the EU-APR, which is not incorporated into SKN 3 and 4 (APR1400 Type) in Korea. Commonly, the risk associated with the NPP can be identified through the PSA. Thus, this paper discusses the low power and shutdown (LPSD) risk reduction effect by MLCS using the Low-Power and Shutdown PSA Result. LPSD level 1 PSA models for EU-APR have been developed. The risk reduction effect by MLCS is discussed. Because the loss of shutdown cooling function during mid-loop is one of the most vulnerable events, the MLCS have a significant influence on CDF in LPSD PSA. The shutdown risk of domestic power plants would likely be reduced if the MLCS is adopted in all operating NPPs in Korea during the mid-loop operation. It is expected that this work will contribute to reduce shutdown risk of domestic power plants

  9. PSA in America

    International Nuclear Information System (INIS)

    Linn, M.A.; Cunningham, M.A.; Johnson, D.H.

    1996-01-01

    Although the concept of acceptable risk has always been the foundation of the nuclear industry design, the use of formal PSA (or PRA-probabilistic risk assessment) in the U.S. nuclear power industry has followed an unusual path in arriving at its current level of notability. Prior to 1975, probabilistic evaluations were limited to a few specific applications such as the evaluation of man-made (i.e., airplane crashes) and natural (i.e., earthquakes) hazards. In 1975, the industry was introduced to comprehensive PSA by the Reactor Safety Study (WASH-1400). However, the study languished in relative obscurity until the accident at Three Mile Island 2 (TMI-2) in 1979. This event significantly altered the industry's view of severe accidents in the U.S. and worldwide. Investigative committees of TMI-2 recommended that PSA techniques be more widely used to augment the traditional deterministic methods of determining nuclear plant safety. This initiated an unprecedented effort by nuclear regulators and licensees worldwide to significantly improve the state of knowledge of severe accidents at nuclear power plants. In the U.S., use of PSA began to increase as evidenced by its application in the anticipated transient without scram and station blackout rulemakings, generic issue prioritization and resolution, risk-based inspection guidelines, backfit policy, and technical specification improvements. However, broad application of probabilistic techniques to the industry as a whole was initiated in 1986 with the publication of Safety Goals for the Operation of Nuclear Power Plant; Policy Statement. This put PSA front and center in the U.S. regulatory arena by open-quotes establish[ing] goals that broadly define an acceptable level of radiological risk that might be imposed on the public as a result of nuclear power plant operation.close quotes Both qualitative safety goals and quantitative objectives were articulated in this policy statement

  10. Long-term longitudinal changes in baseline PSA distribution and estimated prevalence of prostate cancer in male Japanese participants of population-based PSA screening.

    Science.gov (United States)

    Oki, Ryo; Ito, Kazuto; Suzuki, Rie; Fujizuka, Yuji; Arai, Seiji; Miyazawa, Yoshiyuki; Sekine, Yoshitaka; Koike, Hidekazu; Matsui, Hiroshi; Shibata, Yasuhiro; Suzuki, Kazuhiro

    2018-04-26

    Japan has experienced a drastic increase in the incidence of prostate cancer (PC). To assess changes in the risk for PC, we investigated baseline prostate specific antigen (PSA) levels in first-time screened men, across a 25-year period. In total, 72,654 men, aged 50-79, underwent first-time PSA screening in Gunma prefecture between 1992 and 2016. Changes in the distribution of PSA levels were investigated, including the percentage of men with a PSA above cut-off values and linear regression analyses comparing log 10 PSA with age. The 'ultimate incidence' of PC and clinically significant PC (CSPC) were estimated using the PC risk calculator. Changes in the age-standardized incidence rate (AIR) during this period were analyzed. The calculated coefficients of linear regression for age versus log 10 PSA fluctuated during the 25-year period, but no trend was observed. In addition, the percentage of men with a PSA above cut-off values varied in each 5-year period, with no specific trend. The 'risk calculator (RC)-based AIR' of PC and CSPC were stable between 1992 and 2016. Therefore, the baseline risk for developing PC has remained unchanged in the past 25 years, in Japan. The drastic increase in the incidence of PC, beginning around 2000, may be primarily due to increased PSA screening in the country. © 2018 UICC.

  11. Applicability of living PSA in NPP modernization

    International Nuclear Information System (INIS)

    Himanen, R.

    1999-01-01

    Recently the utility Teollisuuden Voima Oy (TVO) has modernized the Olkiluoto 1 and 2 nuclear units and increased the net electric power by 18 per cent. Level 2 PSA was performed during the modernization project and the living level 1 PSA was used to support the design of the plant modifications. The plant specific living PSA model was a powerful tool when evaluating modernization alternatives. Successive support of safety management with the PSA model requires, that both the utility and the Regulatory Body understand capability and limitations of the model in details. TVO has prepared an internal procedure that presents in detail the practices and responsibilities concerning living PSA. The procedure is based on general guidelines and requirements on probabilistic safety analysis of nuclear power plants in Finland, released by the Regulatory Body. Living PSA requires that also the procedure for the use of living PSA is living. The recently published USNRC Regulatory Guides on PSA will be taken into account in the next version of the TVO PSA procedure. The PSA Peer Review Certification Process is one way to evaluate the quality of PSA in general, but also to detect the weaknesses of the PSA. However, the Certification Process cover only limited scope of PSA omitting e.g. all other external events except internal floods. This paper gives an overview on the scope of living PSA for Olkiluoto 1 and 2, and presents some examples on the real use of PSA concerning the modernization of the plant. Definition of quantitative dependability requirements for renovated systems is possible, but on the other hand, proving of these targets is in some cases extremely difficult, because of lacking dependability data. The problems are mainly concerned in systems with of programmable logic control. (au)

  12. The diagnostic value of PSA, cPSA and bone scintigraphy for early skeletal metastasis of prostate cancer

    International Nuclear Information System (INIS)

    Xue Zhongguang

    2007-01-01

    Objective: To evaluate the value of prostate specific antigen (PSA), complexed prostate specific antigen (cPSA) and bone scintigraphic imaging in diagnosis of early skeletal metastasis of prostate cancer. Methods: 152 patients (74 with prostate cancer, 78 with benign prostate disease) and 90 controls were examined for the serum concentrations of PSA and cPSA. At the same time, the 74 patients with PCa were examined with bone scintigraphy. The cPSA/PSA ratio was calculated. Results: Serum PSA, cPSA levels and cPSA/PSA ratio of patients with prostate cancer were significantly higher than those in benign prostate patients and controls. In addition, the serum PSA, cPSA levels and cPSA/PSA ratio in prostate cancer patients with skeletal metastasis were remarkably higher than those in patients without skeletal metastasis, and the differences were significant (P 20 μg/L, cPSA>10 μg/L, cPSA/PSA>0.80, there is a high probability that skeletal metastasis of prostate cancer would be present and bone scintigraphy should be performed. (authors)

  13. Prevalence and causes of abnormal PSA recovery.

    Science.gov (United States)

    Lautenbach, Noémie; Müntener, Michael; Zanoni, Paolo; Saleh, Lanja; Saba, Karim; Umbehr, Martin; Velagapudi, Srividya; Hof, Danielle; Sulser, Tullio; Wild, Peter J; von Eckardstein, Arnold; Poyet, Cédric

    2018-01-26

    Prostate-specific antigen (PSA) test is of paramount importance as a diagnostic tool for the detection and monitoring of patients with prostate cancer. In the presence of interfering factors such as heterophilic antibodies or anti-PSA antibodies the PSA test can yield significantly falsified results. The prevalence of these factors is unknown. We determined the recovery of PSA concentrations diluting patient samples with a standard serum of known PSA concentration. Based on the frequency distribution of recoveries in a pre-study on 268 samples, samples with recoveries 120% were defined as suspect, re-tested and further characterized to identify the cause of interference. A total of 1158 consecutive serum samples were analyzed. Four samples (0.3%) showed reproducibly disturbed recoveries of 10%, 68%, 166% and 4441%. In three samples heterophilic antibodies were identified as the probable cause, in the fourth anti-PSA-autoantibodies. The very low recovery caused by the latter interference was confirmed in serum, as well as heparin- and EDTA plasma of blood samples obtained 6 months later. Analysis by eight different immunoassays showed recoveries ranging between PSA which however did not show any disturbed PSA recovery. About 0.3% of PSA determinations by the electrochemiluminescence assay (ECLIA) of Roche diagnostics are disturbed by heterophilic or anti-PSA autoantibodies. Although they are rare, these interferences can cause relevant misinterpretations of a PSA test result.

  14. Can PSA Reflex Algorithm be a valid alternative to other PSA-based prostate cancer screening strategies?

    Science.gov (United States)

    Caldarelli, G; Troiano, G; Rosadini, D; Nante, N

    2017-01-01

    The available laboratory tests for the differential diagnosis of prostate cancer, are represented by the total PSA, the free PSA, and the free/total PSA ratio. In Italy most of doctors tend to request both total and free PSA for their patients even in cases where the total PSA doesn't justify the further request of free PSA, with a consequent growth of the costs for the National Health System. The aim of our study was to predict the saving in Euro (due to reagents) and reduction in free PSA tests, applying the "PSA Reflex" algorithm. We calculated the number of total PSA and free PSA exams performed in 2014 in the Hospital of Grosseto and, simulating the application of the "PSA Reflex" algorithm in the same year, we calculated the decrease in the number of free PSA requests and we tried to predict the Euro savings in reagents, obtained from this reduction. In 2014 in the Hospital of Grosseto 25,955 total PSA tests have been performed: 3,631 (14%) resulted greater than 10 ng / ml; 7,686 (29.6%) between 2 and 10 ng / ml; 14,638 (56.4%) lower than 2 ng / ml. The performed free PSA tests were 16904. Simulating the use of "PSA Reflex" algorithm, the free PSA tests would be performed only in cases with total PSA values between 2 and 10 ng / mL with a saving of 54.5% of free PSA exams and of 8,971 euros, only for reagents. Our study showed that the "PSA Reflex" algorithm is a valid alternative leading to a reduction of the costs. The estimated intralaboratory savings, due to the reagents, seem to be modest, however, they are followed by the additional savings due to the other diagnostic processes for prostate cancers.

  15. Association of GPs' risk attitudes, level of empathy, and burnout status with PSA testing in primary care

    DEFF Research Database (Denmark)

    Pedersen, Anette F; Carlsen, Anders H; Vedsted, Peter

    2015-01-01

    Denne artikel undersøger, om variationen i raten af PSA-tests mellem alment praktiserende læger kan forklares af psykologiske faktorer som f.eks. lægens risikovillighed. Resultaterne viser, at lægens risikovillighed influerer på raten af PSA-tests. Forfatterne finder blandt andet, at patienter, som...... er registreret hos en læge med mange bekymringer for fejlbehandlinger, har større sandsynlighed for at få taget en PSA-test. Patienter, som er registreret hos en læge, som har en høj tolerance for flertydighed i lægearbejdet, har derimod mindre sandsynlighed for at få foretaget en PSA-test. Patienter......, som er registreret hos en læge med høj tolerance for flertydighed eller en tilbøjelighed til risikobetonet adfærd, har en mindre sandsynlighed for at få gentaget en tidligere normal PSA-test. Undersøgelsen bygger på spørgeskemabesvarelser fra 129 alment solo-praktiserende læger i Region Midtjylland...

  16. Methodology - PSA Regulatory handbook. Comparisons to a modern PSA study

    International Nuclear Information System (INIS)

    Bostroem, Urban; Jung, Gunnar; Flodin, Yngve

    2003-03-01

    The regulatory handbook is applicable to all types of initiating events and all operating conditions. It should be noted that it does not make the traditional subdivision of PSA into internal and external events, level 1 and level 2 PSA, or power operation and shut-down. The reason for this is that this has given the regulatory handbook a more logical structure, and that this approach underlines the integrated character of PSA when it comes to creating the plan risk profile. The regulatory handbook has been structured following the requirements on a PSA for a nuclear power plant, as this is the most demanding application. However, it is applicable also to the analysis of other nuclear installations. The purpose of the comparative review presented in this report has been to, as part of a quality review establish the PSA Handbook, compare (parts of) the handbook and its criteria with a recent PSA analysis, and to identify major discrepancies. Considerable weight has also been allocated to a review of the plant model (Risk Spectrum event trees and fault trees). The results presented in the report are not based on a complete review of the PSA in question (or of the complete PSA Handbook). Following discussions between the SKI and SwedPower, and based on the experience of the SwedPower reviewers, the following issues were chosen to be the main parts of the project: 1) General comparison according to content and transparency - Levels of ambition in PSA Handbook, PSA method description and actual PSA report. 2) Detailed comparison of: Selected component failure data - Assumptions regarding room events - CCI frequencies, realism, identification, categorisation - Taking credit for non-safety classified systems - Event tree modelling - Presentation of results 3) Fault tree model, specifically - Time frame for crediting of battery capacity - Modelling of regulators - Modelling of dependencies for room events - general quality, like how the paper documentation and the logic

  17. Malakoplakia of the prostate diagnosed by elevated PSA level and transrectal prostate biopsy

    Directory of Open Access Journals (Sweden)

    Sacit Nuri Görgel

    2011-04-01

    Full Text Available Malakoplakia is an inflammation which is thought to develop secondary to chronic Escherichia coli infections. Although often seen in the genitourinary tract, it can also be seen in colon, stomach, lung, liver, bone, uterus, and skin. In this case report, we present prostatic malakoplakia diagnosed by elevated prostate-specific antigen level and transrectal prostate biopsy.

  18. Predictive value of [-2]propsa (p2psa and its derivatives for the prostate cancer detection in the 2.0 to 10.0ng/mL PSA range

    Directory of Open Access Journals (Sweden)

    I. Vukovic

    Full Text Available ABSTRACT Introduction To assess predictive value of new tumor markers, precursor of prostate specific antigen (p2PSA and its derivates-%p2PSA and prostate health index (PHI in detection of patients with indolent and aggressive prostate cancer (PC in a subcohort of man whose total PSA ranged from 2 to 10ng/mL. Materials and Methods This cross-sectional study included 129 consecutive male patients aged over 50 years, with no previous history of PC and with normal digital rectal examination findings, but with serum PSA in interval between 2 and 10ng/mL. All patients underwent standard transrectal ultrasonography guided prostate biopsy for the first time. For all patients, serum PSA, free PSA (fPSA and p2PSA were measured and PHI and %p2PSA were calculated. Results PHI and %p2PSA levels were significanlty higher in patients with PC compared to those without this malignancy. The same findings have been observed in group of patients with Gleason score ≥7 compared to those with Gleason score <7. ROC analysis reveled the highest area under the curve with these two markers. Multivariate logistic regression showed significant improvement in PC detection and its agressive form (assumed as Gleason score ≥7. Conclusions New markers, derivates of p2PSA (especially %p2PSA and PHI, represente potentially very important clinical tool for predicting presence of PC, and even more important, to discriminate patients with Gleason score <7 from those with Gleason score ≥7 with total PSA in range from 2 to 10ng/mL.

  19. Predictive value of [-2]propsa (p2psa) and its derivatives for the prostate cancer detection in the 2.0 to 10.0ng/mL PSA range.

    Science.gov (United States)

    Vukovic, I; Djordjevic, D; Bojanic, N; Babic, U; Soldatovic, I

    2017-01-01

    To assess predictive value of new tumor markers, precursor of prostate specific antigen (p2PSA) and its derivates-%p2PSA and prostate health index (PHI) in detection of patients with indolent and aggressive prostate cancer (PC) in a subcohort of man whose total PSA ranged from 2 to 10ng/mL. This cross-sectional study included 129 consecutive male patients aged over 50 years, with no previous history of PC and with normal digital rectal examination findings, but with serum PSA in interval between 2 and 10ng/mL. All patients underwent standard transrectal ultrasonography guided prostate biopsy for the first time. For all patients, serum PSA, free PSA (fPSA) and p2PSA were measured and PHI and %p2PSA were calculated. PHI and %p2PSA levels were significanlty higher in patients with PC compared to those without this malignancy. The same findings have been observed in group of patients with Gleason score ≥7 compared to those with Gleason score <7. ROC analysis reveled the highest area under the curve with these two markers. Multivariate logistic regression showed significant improvement in PC detection and its agressive form (assumed as Gleason score ≥7). New markers, derivates of p2PSA (especially %p2PSA and PHI), represente potentially very important clinical tool for predicting presence of PC, and even more important, to discriminate patients with Gleason score <7 from those with Gleason score ≥7 with total PSA in range from 2 to 10ng/mL. Copyright® by the International Brazilian Journal of Urology.

  20. Uncertainty and sensitivity analysis methodology in a level-I PSA (Probabilistic Safety Assessment)

    International Nuclear Information System (INIS)

    Nunez McLeod, J.E.; Rivera, S.S.

    1997-01-01

    This work presents a methodology for sensitivity and uncertainty analysis, applicable to a probabilistic safety assessment level I. The work contents are: correct association of distributions to parameters, importance and qualification of expert opinions, generations of samples according to sample sizes, and study of the relationships among system variables and system response. A series of statistical-mathematical techniques are recommended along the development of the analysis methodology, as well different graphical visualization for the control of the study. (author) [es

  1. Level 1 and 2 PSA methodology taking into account new design, operating and safety factors. Rev. 1

    International Nuclear Information System (INIS)

    Jirsa, P.; Patrik, M.

    2000-11-01

    The status of probabilistic safety assessment (PSA) is discussed (i) in relation to the expected nature of 'revolutionary' innovations and (ii) in the light of the EUR document, summarizing requirements put by European NPP operators on the future NPP design. The aims included: (1) analysis of limitations to the current PSA methodology; (2) specification of physical and operation processes the knowledge of which is necessary to ensure the safety criteria of advanced reactors; (3) summarisation of existing knowledge and description formats of the processes; (4) identification of theoretical and experimental work required to address the problem, preparation of data and computer codes, ensuring traceability to EU developmental programs. (P.A.)

  2. Predictor of response to salvage radiotherapy in patients with PSA recurrence after radical prostatectomy. The usefulness of PSA doubling time

    International Nuclear Information System (INIS)

    Numata, Kousaku; Azuma, Koji; Hashine, Katsuyoshi; Sumiyoshi, Yoshiteru

    2005-01-01

    We assessed predictors of response to salvage radiotherapy (sRT) in patients with prostate-specific antigen (PSA) recurrence after radical prostatectomy. A total of 21 patients receiving sRT for PSA recurrence without systemic progression after radical prostatectomy had medical records available for retrospective review. We defined sRT as external beam radiotherapy for patients with a continuous increase in PSA level≥0.2 ng/ml after radical prostatectomy. Response was defined as achievement of a PSA nadir of ≤0.1 ng/ml. Various pre-treatment parameters were evaluated retrospectively. The median follow-up period after sRT was 38 months. Of the 21 patients, 15 were good responders (71%). The only predictive factor was PSA doubling time (PSADT). Age and PSA level at diagnosis, Gleason score and surgical margin status were not significant predictors of response. The median PSADT in responders was 6.2 months versus 1.9 months in non-responders (P=0.019). The patients with a PSADT of ≥5 months were all responders. PSADT appears to be a good predictor of response to sRT. sRT was especially effective when PSADT was ≥5 months. (author)

  3. Endogenous and exogenous testosterone and the risk of prostate cancer and increased prostate-specific antigen (PSA) level: a meta-analysis.

    Science.gov (United States)

    Boyle, Peter; Koechlin, Alice; Bota, Maria; d'Onofrio, Alberto; Zaridze, David G; Perrin, Paul; Fitzpatrick, John; Burnett, Arthur L; Boniol, Mathieu

    2016-11-01

    To review and quantify the association between endogenous and exogenous testosterone and prostate-specific antigen (PSA) and prostate cancer. Literature searches were performed according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. Prospective cohort studies that reported data on the associations between endogenous testosterone and prostate cancer, and placebo-controlled randomized trials of testosterone replacement therapy (TRT) that reported data on PSA and/or prostate cancer cases were retained. Meta-analyses were performed using random-effects models, with tests for publication bias and heterogeneity. Twenty estimates were included in a meta-analysis, which produced a summary relative risk (SRR) of prostate cancer for an increase of 5 nmol/L of testosterone of 0.99 (95% confidence interval [CI] 0.96, 1.02) without heterogeneity (I² = 0%). Based on 26 trials, the overall difference in PSA levels after onset of use of TRT was 0.10 ng/mL (-0.28, 0.48). Results were similar when conducting heterogeneity analyses by mode of administration, region, age at baseline, baseline testosterone, trial duration, type of patients and type of TRT. The SRR of prostate cancer as an adverse effect from 11 TRT trials was 0.87 (95% CI 0.30; 2.50). Results were consistent across studies. Prostate cancer appears to be unrelated to endogenous testosterone levels. TRT for symptomatic hypogonadism does not appear to increase PSA levels nor the risk of prostate cancer development. The current data are reassuring, although some caution is essential until multiple studies with longer follow-up are available. © 2016 The Authors BJU International © 2016 BJU International Published by John Wiley & Sons Ltd.

  4. Value of contrast-enhanced sonographic micro flow imaging for prostate cancer detection with t-PSA level of 4–10 ng/mL

    International Nuclear Information System (INIS)

    Guo, Yi-Fen; Li, Feng-Hua; Xie, Shao-Wei; Xia, Jian-Guo; Fang, Hua; Li, Hong-Li

    2012-01-01

    Objectives: To compare the efficiency of contrast-enhanced ultrasonographic micro flow imaging (MFI) with conventional transrectal ultrasound (TRUS) in detecting prostate cancer with serum total prostate-specific antigen (t-PSA) of 4.0–10.0 ng/mL. To evaluate the value of contrast-enhanced ultrasonographic MFI in detecting prostate cancer with t-PSA in diagnostic gray zone. Methods: 47 patients with t-PSA 4.0–10.0 ng/mL underwent gray scale, power Doppler TRUS and MFI examinations before ultrasound guided biopsies. Biopsies were performed at twelve sites in the base, the mid-gland and the apex of the prostate in each patient, when there was no abnormal ultrasound finding. When an abnormality was present at MFI, the biopsy specimen from the corresponding site was directed toward the abnormal finding. With histological results of prostate biopsy as reference standards, we assessed the cancer detection of these three methods. Results: 564 specimens were collected in this study, in which 101 were prostate cancer confirmed histologically. 152 of 564 specimens were demonstrated abnormal on MFI images, in which 71 were malignant and 81 were benign confirmed histologically. The sensitivity, specificity, accuracy, positive predictive value (PPV) and negative predictive value (NPV) for MFI in detecting prostate caner were 70.3%, 82.5%, 80.3%, 46.7% and 92.7%, respectively. The sensitivity and NPV for MFI were significantly better than gray scale (38.6%, 86.9%) and power Doppler (32.7%, 86.0%) (P < 0.001) TRUS. Conclusions: Contrast-enhanced ultrasonographic MFI could significantly improve the detection rate of prostate cancer with t-PSA in diagnostic gray zone (4–10 ng/mL) than conventional ultrasound.

  5. Risk Metrics and Measures for an Extended PSA

    International Nuclear Information System (INIS)

    Wielenberg, A.; Loeffler, H.; Hasnaoui, C.; Burgazzi, L.; Cazzoli, E.; Jan, P.; La Rovere, S.; Siklossy, T.; Vitazkova, J.; Raimond, E.

    2016-01-01

    This report provides a review of the main used risk measures for Level 1 and Level 2 PSA. It depicts their advantages, limitations and disadvantages and develops some more precise risk measures relevant for extended PSAs and helpful for decision-making. This report does not recommend or suggest any quantitative value for the risk measures. It does not discuss in details decision-making based on PSA results neither. The choice of one appropriate risk measure or a set of risk measures depends on the decision making approach as well as on the issue to be decided. The general approach for decision making aims at a multi-attribute approach. This can include the use of several risk measures as appropriate. Section 5 provides some recommendations on the main risk metrics to be used for an extended PSA. For Level 1 PSA, Fuel Damage Frequency and Radionuclide Mobilization Frequency are recommended. For Level 2 PSA, the characterization of loss of containment function and a total risk measure based on the aggregated activity releases of all sequences rated by their frequencies is proposed. (authors)

  6. Percentage of free prostate-specific antigen (PSA) is a useful method in deciding to perform prostate biopsy with higher core numbers in patients with low PSA cut-off values.

    Science.gov (United States)

    Yilmaz, Hasan; Ciftci, Seyfettin; Yavuz, Ufuk; Ustuner, Murat; Saribacak, Ali; Dillioglugil, Ozdal

    2015-06-01

    The aim of this study was to evaluate the predictive role of percentage of free prostate-specific antigen (%fPSA) cut-points in prostate cancer (PCa) detection in patients with total PSA (tPSA) levels between 2.5 ng/mL and 10.0 ng/mL. In total, 1321 consecutive initial transrectal ultrasound (TRUS)-guided 12-core biopsies performed between 2005 and 2011 were evaluated retrospectively. Benign pathologies, high-grade prostatic intraepithelial neoplasia, and atypical small acinary proliferations were categorized as noncancerous (benign), and prostate adenocarcinomas were categorized as cancerous (malignant). The patients were categorized according to: Catalona's published %fPSA categories ( 25%); digital rectal examination (DRE) results [benign (negative) or suspicious of malignancy (positive)]. There was a significant relationship between the %fPSA cut-points and detection of PCa in DRE-negative patients. The presence of a 10% cut-point increased the probability of PCa threefold. The %fPSA was significantly more related to PCa than the tPSA value in receiver operating characteristic (ROC) curve analyses (p = 0.001). Based on our findings, a lower %fPSA, especially <10%, is an important parameter when deciding whether to perform a biopsy on patients with a tPSA between 2.5 ng/mL and 10 ng/mL. Copyright © 2015. Published by Elsevier Taiwan.

  7. Putting PSA to work

    International Nuclear Information System (INIS)

    Gubler, R.; Gomez-Cobo, A.

    1998-01-01

    The IAEA has, during the last three years, been working intensively on PSA applications. The draft TECDOC prepared during these activities, ''PSA Applications'' is summarized in this paper. Actual events at nuclear facilities provide an important basis to compare PSAs with reality. PSA based operational event analysis therefore can be used to evaluate the importance of operational events from a risk perspective but also can contribute to validating and enhancing PSAs and to continuously check whether or not the PSA models are adequate, appropriate and complete. The work of the IAEA in this area is therefore summarized as well. In a companion paper, titled ''Towards a credible PSA fit for applications'', two specific aspects regarding the quality of the PSA to be used are discussed in detail, namely the Living PSA concept, which ensures that the PSA reflects actual design and operational features and Quality Assurance for PSA. (author)

  8. PSA Review Handbook

    International Nuclear Information System (INIS)

    Hallman, Anders; Nyman, Ralph; Knochenhauer, Michael

    2004-05-01

    The Swedish Nuclear Power Inspectorate (SKI) expresses requirements on the performance of PSAs as well as on PSA activities in general in the the regulatory document 'Regulations Concerning Safety in Certain Nuclear Facilities', SKlFS 1998:1. The follow-up of these activities is part of the inspection tasks of the SKI. In view or this, there is a need for documented guidelines on now to perform these inspections and reviews. The SKI PSA Review Handbook is intended to be a support in the SKI inspection and control of the PSA activities or the licensees. These PSA activities include both the organisation and working procedures of the licensee, the layout and contents of the PSA, and its areas of application. Using the regulation SKIFS 1998:1 as a starting point, the review handbook presents important aspects to be considered when judging whether a licensee fulfils the requirements on PSA activities, including the performance of PSA:s or PSA applications. The handbook shall also be a guidance for the review of PSA:s. However, the intention of the PSA Review Handbook is not to be a handbook for how a PSA is performed. The PSA Review Handbook is applicable to all types or initiating events and all operating conditions, and has been structured in a way, which stresses the integrated characteristics of PSA in the creation of the risk picture of a plant. The PSA Review Handbook has been based on the requirements for PSA of nuclear power plants, as this is the most extensive application. However, the relevant parts of it are also applicable when analysing other nuclear installations. The PSA Review Handbook is published as a research report as its contents are judged to be of general interest, and the SKI welcomes comments to the handbook. An update or the PSA Review Handbook may be required as experience with the use of the handbook is acquired and if general PSA requirements change

  9. The effect of high level natural ionizing radiation on expression of PSA, CA19-9 and CEA tumor markers in blood serum of inhabitants of Ramsar, Iran

    International Nuclear Information System (INIS)

    Heidari, Mohammad Hassan; Porghasem, Mohsen; Mirzaei, Nazanin; Mohseni, Jafar Hesam; Heidari, Matine; Azargashb, Eznollah; Movafagh, Abolfazl; Heidari, Reihane; Molouki, Aidin; Larijani, Leila

    2014-01-01

    Since several high level natural radiation areas (HLNRAs) exist on our planet, considerable attention has been drawn to health issues that may develop as the result of visiting or living in such places. City of Ramsar in Iran is an HNLRA, and is a tourist attraction mainly due to its hot spas. However, the growing awareness over its natural radiation sources has prompted widespread scientific investigation at national level. In this study, using an ELISA method, the level of expression of three tumor markers known as carcinoembryonic antigen (CEA), prostate-specific antigen (PSA) and carcino antigen 19-9 (CA19-9) in blood serum of 40 local men of Ramsar (subject group) was investigated and compared to 40 men from the city of Noshahr (control group). Noshahr was previously identified as a normal level natural radiation area (NLNRA) that is some 85 km far from Ramsar. According to statistical analysis, there was a significant difference in the levels of PSA and CA19-9 markers between the two groups (p < 0.001) with those of Ramsar being considerably higher. CEA level did not show any difference. Although some of the volunteers tested positive to the markers, they were in good health as confirmed by the physician. Moreover, the high number of positive markers in Noshahr was considerable. Therefore, future study is needed to further validate this result and to determine the level of positivity to tumor markers in both cities. -- Highlights: • Expression of three tumor markers was examined in 80 volunteers from Ramsar. • There was a significant difference in the levels of PSA and CA19-9 markers. • Some of the volunteers from the control city of Noshahr also tested positive. • Radiation might have caused an adaptive response in people of Ramsar. • Further study is necessary to re-confirm the positivity to tumor marker

  10. Development and perspectives of PSA in Cuba

    International Nuclear Information System (INIS)

    1996-01-01

    During the last decade the GDA/PSA has carried out the pre-operational PSA task for the Juragua Nuclear Power Plant. Since 1991 the work has been accomplished in the frames of the IAEA Technical Assistance Project CUB/9/008. The paper describes the stages of this study, (concluding with the Final Report of the pre-operational Level 1 PSA Rev. O), its assumptions, limitations and the main results and concluding remarks

  11. Use of PSA to support accident management at NPPs

    International Nuclear Information System (INIS)

    Gomez Cobo, A.

    1997-01-01

    The presentation discusses the following: Overview of PSA level 2; Introduction: Framework; Accident Progression Phenomena in the Confinement/containment; Severe Accident Sequences; Examples; Results and Insights. Accident Management: Concepts; Process; Use of PSA to support Accident; Management

  12. Correlative study of SPECT bone scan, serum tPSA and fPSA/tPSA ratio and the pathological grade of prostate cancer with bone metastasis

    International Nuclear Information System (INIS)

    Xu Haiqing; Duan Jun

    2011-01-01

    Objective: To study the rules and characteristics of SPECT bone scan, serum TPSA, fPSA/tPSA ratio and the pathological grade of prostate cancer with bone metastasis. Methods: Nuclear medicine SPECT bone scan as the gold standard, retrospective analysis of the in vitro radioimmunoassay in 107 patients with prostate cancer serum PSA (prostate specific antigen) levels, serum fPSA/tPSA ratio and whole body bone imaging studies and pathological classification. Results: 107 patients with prostate cancer : 49 patients had bone metastases, accounting for 45.8% (49/107), in which groups of different pathological comparison between the incidence of bone metastasis significantly, the lower the degree of differentiation, the more the incidence of bone metastases high; with elevated levels of tPSA, the incidence of bone metastasis increased significantly; serum tPSA 4 - 40 ng/ml, the use of fPSA/tPSA ratio may improve the diagnostic specificity of prostate cancer. Conclusion: Patients with bone metastases of prostate cancer incidence and degree of differentiation of prostate cancer, serum PSA levels and fPSA/tPSA ratio of a certain relationship. The lower degree of differentiation,the higher the incidence of bone metastasis. (authors)

  13. Proteolytic activity of prostate-specific antigen (PSA towards protein substrates and effect of peptides stimulating PSA activity.

    Directory of Open Access Journals (Sweden)

    Johanna M Mattsson

    Full Text Available Prostate-specific antigen (PSA or kallikrein-related peptidase-3, KLK3 exerts chymotrypsin-like proteolytic activity. The main biological function of PSA is the liquefaction of the clot formed after ejaculation by cleavage of semenogelins I and II in seminal fluid. PSA also cleaves several other substrates, which may explain its putative functions in prostate cancer and its antiangiogenic activity. We compared the proteolytic efficiency of PSA towards several protein and peptide substrates and studied the effect of peptides stimulating the activity of PSA with these substrates. An endothelial cell tube formation model was used to analyze the effect of PSA-degraded protein fragments on angiogenesis. We showed that PSA degrades semenogelins I and II much more efficiently than other previously identified protein substrates, e.g., fibronectin, galectin-3 and IGFBP-3. We identified nidogen-1 as a new substrate for PSA. Peptides B2 and C4 that stimulate the activity of PSA towards small peptide substrates also enhanced the proteolytic activity of PSA towards protein substrates. Nidogen-1, galectin-3 or their fragments produced by PSA did not have any effect on endothelial cell tube formation. Although PSA cleaves several other protein substrates, in addition to semenogelins, the physiological importance of this activity remains speculative. The PSA levels in prostate are very high, but several other highly active proteases, such as hK2 and trypsin, are also expressed in the prostate and may cleave protein substrates that are weakly cleaved by PSA.

  14. Proteolytic Activity of Prostate-Specific Antigen (PSA) towards Protein Substrates and Effect of Peptides Stimulating PSA Activity

    Science.gov (United States)

    Mattsson, Johanna M.; Ravela, Suvi; Hekim, Can; Jonsson, Magnus; Malm, Johan; Närvänen, Ale; Stenman, Ulf-Håkan; Koistinen, Hannu

    2014-01-01

    Prostate-specific antigen (PSA or kallikrein-related peptidase-3, KLK3) exerts chymotrypsin-like proteolytic activity. The main biological function of PSA is the liquefaction of the clot formed after ejaculation by cleavage of semenogelins I and II in seminal fluid. PSA also cleaves several other substrates, which may explain its putative functions in prostate cancer and its antiangiogenic activity. We compared the proteolytic efficiency of PSA towards several protein and peptide substrates and studied the effect of peptides stimulating the activity of PSA with these substrates. An endothelial cell tube formation model was used to analyze the effect of PSA-degraded protein fragments on angiogenesis. We showed that PSA degrades semenogelins I and II much more efficiently than other previously identified protein substrates, e.g., fibronectin, galectin-3 and IGFBP-3. We identified nidogen-1 as a new substrate for PSA. Peptides B2 and C4 that stimulate the activity of PSA towards small peptide substrates also enhanced the proteolytic activity of PSA towards protein substrates. Nidogen-1, galectin-3 or their fragments produced by PSA did not have any effect on endothelial cell tube formation. Although PSA cleaves several other protein substrates, in addition to semenogelins, the physiological importance of this activity remains speculative. The PSA levels in prostate are very high, but several other highly active proteases, such as hK2 and trypsin, are also expressed in the prostate and may cleave protein substrates that are weakly cleaved by PSA. PMID:25237904

  15. Development of severe accident evaluation technology (level 2 PSA) for sodium-cooled fast reactors. (5) Identification of dominant factors in ex-vessel accident sequences

    International Nuclear Information System (INIS)

    Ohno, Shuji; Seino, Hiroshi; Miyahara, Shinya

    2009-01-01

    The evaluation of accident progression outside of a reactor vessel (ex-vessel) and subsequent transfer behavior of radioactive materials is of great importance from the viewpoint of Level 2 PSA. Hence typical ex-vessel accident sequences in the JAEA Sodium-cooled Fast Reactor are qualitatively discussed in this paper and dominant behaviors or factors in the sequences are investigated through parametric calculations using the CONTAIN/LMR code. Scenarios to be focused on are, 1) sodium vapor leakage from the reactor vessel and 2) sodium-concrete reaction, which are both to be considered in the accident category of LOHRS (loss of heat removal system) and might be followed by an early containment failure due to the thermal effect of sodium combustion and hydrogen burning respectively. The calculated results clarify that the sodium vapor leak rate and the scale of sodium-concrete reaction are the important factors to dominate the ex-vessel accident progression. In addition to the understandings of the dominant factors, the analyzed results also provide the specific information such as pressure loading value to the containment and the timing of pressurization, which is indispensable as technical base in Level 2 PSA for developing event trees and for quantifying the accident consequences. (author)

  16. Combination of Autoantibody Signature with PSA Level Enables a Highly Accurate Blood-Based Differentiation of Prostate Cancer Patients from Patients with Benign Prostatic Hyperplasia.

    Directory of Open Access Journals (Sweden)

    Petra Leidinger

    Full Text Available Although an increased level of the prostate-specific antigen can be an indication for prostate cancer, other reasons often lead to a high rate of false positive results. Therefore, an additional serological screening of autoantibodies in patients' sera could improve the detection of prostate cancer. We performed protein macroarray screening with sera from 49 prostate cancer patients, 70 patients with benign prostatic hyperplasia and 28 healthy controls and compared the autoimmune response in those groups. We were able to distinguish prostate cancer patients from normal controls with an accuracy of 83.2%, patients with benign prostatic hyperplasia from normal controls with an accuracy of 86.0% and prostate cancer patients from patients with benign prostatic hyperplasia with an accuracy of 70.3%. Combining seroreactivity pattern with a PSA level of higher than 4.0 ng/ml this classification could be improved to an accuracy of 84.1%. For selected proteins we were able to confirm the differential expression by using luminex on 84 samples. We provide a minimally invasive serological method to reduce false positive results in detection of prostate cancer and according to PSA screening to distinguish men with prostate cancer from men with benign prostatic hyperplasia.

  17. The use of PSA in the French regulatory practice

    International Nuclear Information System (INIS)

    Mennesiez, H.

    1994-01-01

    The presentation gives a description of fundamental documents (since 1977-1978) through which have been set up in France probabilistic objectives, and PSAs, including shutdown states, performed for 900-1300 MWe PWR-type nuclear power plants. PSA developments and use, including fire PSA, level 2 and PSA for the future French-German European Pressurized Reactor (EPR) are also discussed

  18. Utility of free prostate specific antigen serum level and its related parameters in the diagnosis of prostate cancer

    Directory of Open Access Journals (Sweden)

    Azmi A Haroun

    2011-01-01

    Full Text Available We evaluated the role of free prostate specific antigen (f-PSA serum level and its related parameters in detecting prostate cancer. This retrospective study was conducted between January 2006 and March 2008. Trans-rectal ultrasound guided prostate biopsy was performed for 107 patients who had total PSA (t-PSA level of either >4 ng/mL with or without palpable nodule or ≤4 ng/mL with palpable nodule on digital rectal examination. The perfor-mance measurements for f-PSA, percent free PSA (%f-PSA and free PSA density (f-PSAD were determined and compared with those for t-PSA and total PSA density (t-PSAD. Descriptive statistics for all variables of interest were calculated, and receiver operating characteristic curves were generated. Nine patients (8.4% had normal histology, 69 patients (64.4% had benign disease and 29 patients (27.1% had prostate cancer. The performance of f-PSA in PCa detection was better than other evaluated parameters. The largest area under the curve for patients in the gray area (t-PSA range 4.1-10 ng/mL was for f-PSA, with a value of 0.64 and a sensitivity and specificity of 44% and 87%, respectively. For %f-PSA, these values were 0.59, 63% and 62%, respectively. For patients with a t-PSA level of 10.1-20 ng/mL, they were 0.68, 67%, and 81%, respectively, for f-PSA, and 0.64, 67%, and 76%, respectively, for %f-PSA. In conclusion, f-PSA serum levels performed better than free to total PSA ratio and t-PSA for prostate cancer screening. It is of clinical value which could affect the biopsy decision avoiding unnecessary interventions.

  19. The effect of high level natural ionizing radiation on expression of PSA, CA19-9 and CEA tumor markers in blood serum of inhabitants of Ramsar, Iran.

    Science.gov (United States)

    Heidari, Mohammad Hassan; Porghasem, Mohsen; Mirzaei, Nazanin; Mohseni, Jafar Hesam; Heidari, Matine; Azargashb, Eznollah; Movafagh, Abolfazl; Heidari, Reihane; Molouki, Aidin; Larijani, Leila

    2014-02-01

    Since several high level natural radiation areas (HLNRAs) exist on our planet, considerable attention has been drawn to health issues that may develop as the result of visiting or living in such places. City of Ramsar in Iran is an HNLRA, and is a tourist attraction mainly due to its hot spas. However, the growing awareness over its natural radiation sources has prompted widespread scientific investigation at national level. In this study, using an ELISA method, the level of expression of three tumor markers known as carcinoembryonic antigen (CEA), prostate-specific antigen (PSA) and carcino antigen 19-9 (CA19-9) in blood serum of 40 local men of Ramsar (subject group) was investigated and compared to 40 men from the city of Noshahr (control group). Noshahr was previously identified as a normal level natural radiation area (NLNRA) that is some 85 km far from Ramsar. According to statistical analysis, there was a significant difference in the levels of PSA and CA19-9 markers between the two groups (p < 0.001) with those of Ramsar being considerably higher. CEA level did not show any difference. Although some of the volunteers tested positive to the markers, they were in good health as confirmed by the physician. Moreover, the high number of positive markers in Noshahr was considerable. Therefore, future study is needed to further validate this result and to determine the level of positivity to tumor markers in both cities. Copyright © 2013 Elsevier Ltd. All rights reserved.

  20. Vaginal Prostate Specific Antigen (PSA) Is a Useful Biomarker of Semen Exposure Among HIV-Infected Ugandan Women.

    Science.gov (United States)

    Woolf-King, Sarah E; Muyindike, Winnie; Hobbs, Marcia M; Kusasira, Adrine; Fatch, Robin; Emenyonu, Nneka; Johnson, Mallory O; Hahn, Judith A

    2017-07-01

    The practical feasibility of using prostate specific antigen (PSA) as a biomarker of semen exposure was examined among HIV-infected Ugandan women. Vaginal fluids were obtained with self-collected swabs and a qualitative rapid test (ABAcard ® p30) was used to detect PSA. Trained laboratory technicians processed samples on-site and positive PSA tests were compared to self-reported unprotected vaginal sex (UVS) in the last 48 h. A total of 77 women submitted 126 samples for PSA testing at up to three study visits. Of these samples, 31 % (n = 39/126) were PSA positive, and 64 % (n = 25/39) of the positive PSA samples were accompanied by self-report of no UVS at the study visit the PSA was collected. There were no reported difficulties with specimen collection, storage, or processing. These findings provide preliminary data on high levels of misreported UVS among HIV-infected Ugandan women using practically feasible methods for PSA collection and processing.

  1. Real-life experience of using conventional disease-modifying anti-rheumatic drugs (DMARDs) in psoriatic arthritis (PsA). Retrospective analysis of the efficacy of methotrexate, sulfasalazine, and leflunomide in PsA in comparison to spondyloarthritides other than PsA and literature review of the use of conventional DMARDs in PsA

    Science.gov (United States)

    Roussou, Euthalia; Bouraoui, Aicha

    2017-01-01

    Objective With the aim of assessing the response to treatment with conventional disease-modifying anti-rheumatic drugs (DMARDs) used in patients with psoriatic arthritis (PsA), data on methotrexate, sulfasalazine (SSZ), and leflunomide were analyzed from baseline and subsequent follow-up (FU) questionnaires completed by patients with either PsA or other spondyloarthritides (SpAs). Material and Methods A single-center real-life retrospective analysis was performed by obtaining clinical data via questionnaires administered before and after treatment. The indices used were erythrocyte sedimentation rate (ESR), C-reactive protein (CRP) level, Bath Ankylosing Spondylitis Disease Activity Index (BASDAI), Bath Ankylosing Spondylitis Function Index (BASFI), wellbeing (WB), and treatment effect (TxE). The indices measured at baseline were compared with those measured on one occasion in a FU visit at least 1 year later. Results A total of 73 patients, 51 with PsA (mean age 49.8±12.8 years; male-to-female ratio [M:F]=18:33) and 22 with other SpAs (mean age 50.6±16 years; M:F=2:20), were studied. BASDAI, BASFI, and WB displayed consistent improvements during FU assessments in both PsA patients and controls in comparison to baseline values. SSZ exhibited better efficacy as confirmed by TxE in both PsA patients and controls. ESR and CRP displayed no differences in either the PsA or the SpA group between the cases before and after treatment. Conclusion Real-life retrospective analysis of three DMARDs used in PsA (and SpAs other than PsA) demonstrated that all three DMARDs that were used brought about improvements in BASDAI, BASFI, TxE, and WB. However, the greatest improvements at FU were seen with SSZ use in both PsA and control cohorts. PMID:28293446

  2. Generation of monoclonal antibodies against prostate specific antigen (PSA) for the detection of PSA and its purification

    International Nuclear Information System (INIS)

    Acevedo Castro, Boris Ernesto

    2012-01-01

    The prostate cancer in Cuba is a problem of health (2672 diagnosed cases and 2769 deaths in 2007). Various diagnostic methods have been implemented for the detection and management of this disease, emphasizing among them (PSA) prostate-specific antigen serological determination. At this work was generated and characterized a panel of 11 antibodies (AcMs) monoclonal IgG1 detected with high affinity described major epitopes of the PSA, both in solution and attached to the test plate. From the panel obtained AcMs was the standardization of an essay type ELISA for the detection of serum total PSA (associated and free) equimolar, based on antibody monoclonal CB-PSA.4 in the coating and the CB-PSA.9 coupled with biotin as liner, with a detection limit of 0.15 ng/mL. Similarly, standardized system for detection in serum free PSA, based on the AcMs CB-PSA.4 (coating) and CB-PSA.2 coupled with biotin (liner), with a detection limit of 0.5 ng/mL. Finally, with the purpose of using PSA as standard in trials type ELISA, developed a simple method of inmunopurificación based on the AcM, CB-PSA.2, which was obtained the PSA with a purity exceeding 90%. Immunoassay Centre on the basis of the AcMs panel and the results of this study, developed and recorded two diagnostic systems for the detection of PSA in human serum. (author)

  3. Levels of plasma selenium and urinary total arsenic interact to affect the risk for prostate cancer.

    Science.gov (United States)

    Hsueh, Yu-Mei; Su, Chien-Tien; Shiue, Horng-Sheng; Chen, Wei-Jen; Pu, Yeong-Shiau; Lin, Ying-Chin; Tsai, Cheng-Shiuan; Huang, Chao-Yuan

    2017-09-01

    This study investigated whether plasma selenium levels modified the risk for prostate cancer (PC) related to arsenic exposure. We conducted a case-control study that included 318 PC patients and 318 age-matched, healthy control subjects. Urinary arsenic profiles were examined using HPLC-HG-AAS and plasma selenium levels were measured by ICP-MS. We found that plasma selenium levels displayed a significant dose-dependent inverse association with PC. The odds ratio (OR) and 95% confidence interval (CI) for PC was 0.07 (0.04-0.13) among participants with a plasma selenium level >28.06 μg/dL vs. ≤19.13 μg/dL. A multivariate analysis showed that participants with a urinary total arsenic concentration >29.28 μg/L had a significantly higher OR (1.75, 1.06-2.89) for PC than participants with ≤29.89 μg/L. The combined presence of a low plasma selenium level and a high urinary total arsenic concentration exponentially increased the OR for PC, and additively interacted with PSA at levels ≥20 ng/mL. This is the first epidemiological study to examine the combined effects of plasma selenium and urinary total arsenic levels on the OR for PC. Our data suggest a low plasma selenium level coupled with a high urinary total arsenic concentration creates a significant risk for aggressive PC. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. Human reliability analysis approach to level 1 PSA - shutdown and low power operation of Mochovce NPP, Unit 1, Slovakia

    International Nuclear Information System (INIS)

    Stojka, Tibor; Holy, Jaroslav

    2003-01-01

    The paper presents general approach, used methods and form of documentation of the results as have been applied within the Human Reliability Analysis (HRA) task of the shutdown and low power PSA (SPSA) study for Mochovce nuclear power plant, Unit 1, Slovakia. The paper describes main goals of the HRA task within the SPSA project, applied methods and data sources. Basic steps of the HRA task and human errors (HE) classification are also specified in its first part. The main part of the paper deals with pre-initiator human errors, human-induced initiators and response to initiator human errors. Since the expert judgment method (SLIM) was used for the last type of human errors probability assessment, also related activities are described including preparation works (performance shaping factors (PSFs) selection, development of PSF classification tables, preparation of aid tools for interview with plant experts), qualitative analysis (sources of information and basic steps) and quantitative analysis itself (human errors classification for final quantification including criteria used for the classification, description of structure of the spreadsheet used for quantification and treatment with dependencies). The last part of the paper describes form of documentation of the final results and provides some findings. (author)

  5. Pretreatment PSA predicts for biochemical disease free survival in patients treated with post-prostatectomy external beam irradiation

    International Nuclear Information System (INIS)

    Crane, C.H.; Kelly, M.; Rich, T.A.

    1996-01-01

    Objective: To assess the outcome and determine prognostic factors for patients treated with external beam radiotherapy following radical prostatectomy. Methods and Materials: Forty-four patients were treated after prostatectomy with radiotherapy between March 1988 and October 1993. All patients were free from clinically or radiographically suspicious local or distant disease. One patient underwent neoadjuvant hormonal therapy, but no other patients received hormonal therapy prior to radiation. Pre-radiotherapy PSA and follow-up PSA data were available in all patients. Four patients had undetectable PSA ( 7, and 11% had nodal involvement. Survival was analyzed using the life table method. Actuarial freedom from biochemical (BCM) failure, defined as a rise of greater than 10% or an undetectable PSA becoming detectable, was the primary endpoint studied. Results: Fifty-nine percent of patients had a detectable PSA return to undetectable levels after XRT. The actuarial five year freedom from biochemical failure for all patients was 24%. A significant difference in BCM disease free survival was seen for patients irradiated with a pre-XRT PSA ≤2.7 versus a pre-XRT PSA >2.7 (p=0.0001). Sixty percent of the former group were BCM disease free versus 0% in the latter. Biochemical disease free survival was not affected by preoperative PSA level, presence of undetectable PSA after surgery, surgery to radiation interval, seminal vesicle invasion, clinical stage, pathologic stage, Gleasons grade, or total dose. There were no symptomatic or clinically suspicious local failures, and there were no grade 3, 4, or 5 acute or late complications. There were 69% grade 1 and 2 acute reactions and one grade 2 late complication. Conclusions: Pelvic radiotherapy for patients with a PSA of ≤2.7 after prostatectomy was effective in biochemically controlling 60% of the patients with four years median follow up. To our knowledge these data represent the longest follow-up for this patient

  6. Clinical evaluation of free to total prostate specific antigen ratio in serum

    International Nuclear Information System (INIS)

    Cheng Wei; Deng Shouzhen; Lin Xiangtong

    1999-01-01

    Free and total prostate specific antigen (F-PSA and T-PSA) in serum were measured with immunoradiometric assay and the F/T-PSA ratio was calculated in 175 patients with T-PSA levels in the range of 4-20 μg/L. Among them 141 patients were benign prostatic hyperplasia (BPH), 23 were untreated prostate cancer (Pca untreated) and 11 were treated prostate cancer (Pca treated). The results showed that difference in F-PSA and F/T-PSA ratio for BPH group and Pca untreated group were statistically significant (P<0.01). The effectiveness of F/T-PSA ratio for Pca (89.9%) was higher than F-PSA (54.8%). The receiver-operating characteristic (ROC) curve showed an improved diagnostic efficacy of F/T-PSA ratio compared with T-PSA for discrimination between BPH and Pca. If mean F/T-PSA ratio value + 1 SE (13.2%) was used in BPH group as discrimination limits of Pca patients, the diagnostic accuracy of BPH group and Pca untreated group were 90.8% and 82.6% respectively. Thereby F/T-PSA ratio may be useful for the differentiation between BPH and prostate cancer

  7. A PSA study for the SMART basic design

    International Nuclear Information System (INIS)

    Han, Sang Hoon; Kim, H. C.; Yang, S. H.; Lee, D. J.

    2002-03-01

    SMART (System-Integrated Modular Advanced Reactor) is under development that is an advanced integral type small and medium category nuclear power reactor with the rated thermal power of 330 MW. A Probabilistic Safety Analysis (PSA) for the SMART basic design has been performed to evaluate the safety and optimize the design. Currently, the basic design is done and the detailed design is not available for the SMART, we made several assumptions about the system design before performing the PSA. The scope of the PSA was limited to the Level-1 internal full power PSA. The level-2 and 3 PSA, the external PSA, and the low power/shutdown PSA will be performed in the final design stage

  8. [Use of [-2] pro PSA and phi index for early detection of prostate cancer: a prospective of 452 patients].

    Science.gov (United States)

    Houlgatte, A; Vincendeau, S; Desfemmes, F; Ramirez, J; Benoist, N; Bensalah, K; Durand, X

    2012-05-01

    Early detection of prostate cancer (Pca) is a real challenge to reduce morbidity and mortality while avoiding over-diagnosis and over-treatment. The prostate specific antigen (PSA) is characterized by its imperfections justifying the evaluation of new serum or urinary specific markers allowing a better selection of patients at risk of developing aggressive Pca. To compare the value of -2pro PSA and phi index to total and free PSA. Serum sampled from 452 patients from two university centers were used to determine levels of PSA before performing biopsies. The patients were included in this study based on the PSA serum concentration between 1.6 ng/mL and 8 ng/mL according to the WHO international standard. All biopsies were performed according to a standardized protocol consisting of 12 cores or more. Sera were analyzed centrally in one of the two institutions with on a single analyzer. Sera from 243 prostate cancer and 208 negative biopsies patients have been taken into account. Sera were analyzed blinded for total PSA, free PSA and [-2] proPSA using Access(®) immunoassay method from Beckman Coulter. The Prostate Health Index (phi) was calculated using the formula phi=([-2] proPSA/fPSA)×sqrt (PSA). The median value of the phi index is significantly (P>0.0001) higher for patients with cancer (phi=65.8) compared to patients with negative biopsies (phi=40.6). At a given sensitivity, the phi index significantly increases the specificity of detection of prostate cancer compared to other markers. The phi index currently appears as the best predictor of prostate cancer for patients with a total PSA between 1.6 and 8 ng/mL according to the WHO standard. The improvement in specificity of the phi index over tPSA could reduce significantly the numbers of unnecessary biopsies. Whether this new biomarker could be an indicator of aggressive prostate cancer remains to be confirmed. Copyright © 2011 Elsevier Masson SAS. All rights reserved.

  9. Repeat prostate-specific antigen (PSA) test before prostate biopsy: a 20% decrease in PSA values is associated with a reduced risk of cancer and particularly of high-grade cancer.

    Science.gov (United States)

    De Nunzio, Cosimo; Lombardo, Riccardo; Nacchia, Antonio; Tema, Giorgia; Tubaro, Andrea

    2018-07-01

    To analyse the impact of repeating a prostate-specific antigen (PSA) level assessment on prostate biopsy decision in a cohort of men undergoing prostate biopsy. From 2015 onwards, we consecutively enrolled, at a single institution in Italy, men undergoing 12-core transrectal ultrasonography-guided prostate needle biopsy. Indication for prostate biopsy was a PSA level of ≥4 ng/mL. Demographic, clinical, and histopathological data were collected. The PSA level was tested at enrolment (PSA 1 ) and 4 weeks later on the day before biopsy (PSA 2 ). Variations in PSA level were defined as: stable PSA 2 within a 10% variation, stable PSA 2 within a 20% variation, PSA 2 decreased by ≥10%, PSA 2 decreased by ≥20%, PSA 2 increased by ≥10%, PSA 2 increased by ≥20%, and PSA 2 PSA within 20% variation had a higher risk of prostate cancer (odds ratio [OR] 1.80, P PSA2 decreased by ≥20% had a lower risk of prostate cancer (OR 0.37, P PSA2 increased by ≥10% had an increased risk of high-grade prostate cancer (OR 1.93, P PSA returned to normal values (PSA levels significantly reduced the risk of high-grade prostate cancer. Further multicentre studies should validate our present results. © 2018 The Authors BJU International © 2018 BJU International Published by John Wiley & Sons Ltd.

  10. Preirradiation PSA predicts biochemical disease-free survival in patients treated with postprostatectomy external beam irradiation

    International Nuclear Information System (INIS)

    Crane, Christopher H.; Rich, Tyvin A.; Read, Paul W.; Sanfilippo, Nicholas J.; Gillenwater, Jay Y.; Kelly, Maria D.

    1997-01-01

    Purpose: To assess the clinical outcome and prostate-specific antigen (PSA) response and to determine prognostic factors for biochemical disease-free survival in patients treated with external beam radiotherapy following radical prostatectomy without hormonal therapy. Methods and Materials: Forty-eight patients were treated after prostatectomy with radiotherapy between March, 1988 and December, 1993. Seven patients had undetectable PSA ( 2.7. Five-year actuarial biochemical disease-free survival values were 71, 48, and 0%, respectively, for the three groups. Biochemical disease-free survival was not affected by preoperative PSA level, clinical stage, Gleason's score, pathologic stage, surgical margins, presence of undetectable PSA after surgery, surgery to radiation interval, total dose, or presence of clinically suspicious local disease. Based on digital rectal exam, there were no local failures. Conclusion: Biochemical disease-free survival after postprostatectomy radiation is predicted by the PSA at the time of irradiation. Clinical local control is excellent, but distant failure remains a significant problem in this population. The addition of concomitant systemic therapy should be investigated in patients with PSA >2.7

  11. Whooping Cough PSA (:30)

    Centers for Disease Control (CDC) Podcasts

    This 30 second PSA encourages pregnant women to get the whooping cough vaccine, called Tdap, during the third trimester of each pregnancy in order to pass antibodies to their babies so they are born with protection against this serious disease.

  12. Methodology for fire PSA during design process

    International Nuclear Information System (INIS)

    Kollasko, Heiko; Blombach, Joerg

    2009-01-01

    Fire PSA is an essential part of a full scope level 1 PSA. Cable fires play an important role in fire PSA. Usually, cable routing is therefore modeled in detail. During the design of new nuclear power plants the information on cable routing is not yet available. However, for the use of probabilistic safety insights during the design and for licensing purposes a fire PSA may be requested. Therefore a methodology has been developed which makes use of the strictly divisional separation of redundancies in the design of modern nuclear power plants: cable routing is not needed within one division but replaced by the conservative assumption that all equipment fails due to a fire in the concerned division; critical fire areas are defined where components belonging to different divisions may be affected by a fire. For the determination of fire frequencies a component based approach is proposed. The resulting core damage frequencies due to fire are conservative. (orig.)

  13. The DnaJ-like zinc finger domain protein PSA2 affects light acclimation and chloroplast development in Arabidopsis thaliana

    Directory of Open Access Journals (Sweden)

    Yan-Wen eWang

    2016-03-01

    Full Text Available The biosynthesis of chlorophylls and carotenoids and the assembly of thylakoid membranes are critical for the photoautotrophic growth of plants. Different factors are involved in these two processes. In recent years, members of the DnaJ-like zinc finger domain proteins have been found to take part in the biogenesis and/or the maintenance of plastids. One member of this family of proteins, PSA2, was recently found to localize to the thylakoid lumen and regulate the accumulation of photosystem I. In this study, we report that the silencing of PSA2 in Arabidopsis thaliana resulted in variegated leaves and retarded growth. Although both chlorophylls and total carotenoids decreased in the psa2 mutant, violaxanthin and zeaxanthin accumulated in the mutant seedlings grown under growth condition. Lower levels of non-photochemical quenching and electron transport rate were also found in the psa2 mutant seedlings under growth condition compared with those of the wild-type plants, indicating an impaired capability to acclimate to normal light irradiance when PSA2 was silenced. Moreover, we also observed an abnormal assembly of grana thylakoids and poorly developed stroma thylakoids in psa2 chloroplasts. Taken together, our results demonstrate that PSA2 is a member of the DnaJ-like zinc finger domain protein family that affects light acclimation and chloroplast development.

  14. Issues reporting PSA in prostate cancer

    International Nuclear Information System (INIS)

    Lange, Paul H.

    1996-01-01

    The National Cancer Institute Prostate; Lung; Colon; Ovarian Cancer Screening (PLCO) project is a multi-center trial developed to investigate the effectiveness of DRE and PSA testing in the early detection and outcome of patients with prostate cancer. Accordingly, the Prostate Cancer Intervention versus Observation Trial (PIVOT) has been launched and is a randomized trial comparing radical prostatectomy versus expectant management for ALCaP. PSA: Initially PSA was thought to be of little value for diagnosis because 20% of men undergoing radical prostatectomy have 'normal' PSA and patients with apparently only symptomatic BPH have 'elevated' levels as follows: 4-10 ng/ml (Tandem-R) - 20%, >10 ng/ml -3%. Yet, PSA has looked attractive as a diagnostic tool in many studies; for example, when PSA was used in a screening approach as the first test which then drove further evaluation (Catalona, Brawer). It was shown that the positive predictive value for PSA's between 4 and 10 is approximately 20% and > 10 approximately 55%. The value of serial PSA's (velocity) is unknown but is under intense study: one major issue is determination of what represents a significant rise (details to be presented). Studies have also revealed that a DRE and PSA are important for optimal results. About 18% of clinically detectable cancers are only DRE positive while about 25 - 30% are only PSA positive. When both a DRE and PSA are used together, very few clinically apparent cancers are missed (3-5%). Recent ROC curves suggest that 4 ng/ml is reasonable. Recently, PSA values for men without apparent cancer were stratified by age, and taking the 2SD, age specific reference values were generated as follows: age 40-49 (0-2.5 ng/ml), 50-59 (0-3.5), 60-69 (0-4.5), 70-70 (0-6.5). Finally, there is the issue about different PSA assays regarding the compatabilities/reliability of the upper limit of normal and serial values. Much of the confusion is because there is no international PSA standard and

  15. Prostate cancer screening by prostate-specific antigen (PSA); a relevant approach for the small population of the Cayman Islands.

    Science.gov (United States)

    Jyoti, Shravana Kumar; Blacke, Camille; Patil, Pallavi; Amblihalli, Vibha P; Nicholson, Amanda

    2018-01-01

    The common tool for diagnosing prostate cancer is prostate-specific antigen (PSA), but the high sensitivity and low specificity of PSA testing are the problems in clinical practice. There are no proper guidelines to investigate the suspected prostate cancer in the Cayman Islands. We correlated PSA levels with the incidence of prostate cancers by tissue diagnosis and proposed logical protocol for prostate screening by using PSA test in this small population. A total of 165 Afro Caribbean individuals who had prostate biopsy done after the investigations for PSA levels from year 2005 to 2015 were studied retrospectively. The patients were divided into subgroups by baseline PSA levels as follows: 100 ng/mL and were correlated to the age and presence of cancer. Benign lesions had lower PSA levels compared to cancer which generally had higher values. Only three cases that had less than 4 ng/mg were turned out to be malignant. When PSA value was more than 100 ng/mL, all the cases were malignant. Between PSA values of 4-100 ng/mL, the probability of cancer diagnosis was 56.71% (76 cancers out of 134 in this range). Limitation of PSA testing has the risk of over diagnosis and the resultant negative biopsies owing to poor specificity. Whereas the cutoff limit for cancer diagnosis still remains 4 ng/mL from our study, most of the patients can be assured of benign lesion below this level and thus morbidity associated with the biopsy can be prevented. When the PSA value is greater than 100 ng, biopsy procedure was mandatory as there were 100% cancers above this level. On the background of vast literature linking PSA to prostate cancer and its difficulty in implementing in clinical practice, we studied literature of this conflicting and complex topic and tried to bring relevant protocols to the small population of Cayman Islands for the screening of prostate cancer. In this study, a total of 165 Afro Caribbean individuals who had prostate biopsy done after the

  16. Decreased total antioxidant levels and increased oxidative stress in ...

    African Journals Online (AJOL)

    21–25 ... Decreased total antioxidant levels and increased oxidative stress in South ... antioxidant-rich diet and lifestyle changes in T2DM patients would help to avert the .... glycation of proteins and the formation of advanced glycosylation.

  17. Programmable automation systems in PSA

    International Nuclear Information System (INIS)

    Pulkkinen, U.

    1997-06-01

    The Finnish safety authority (STUK) requires plant specific PSAs, and quantitative safety goals are set on different levels. The reliability analysis is more problematic when critical safety functions are realized by applying programmable automation systems. Conventional modeling techniques do not necessarily apply to the analysis of these systems, and the quantification seems to be impossible. However, it is important to analyze contribution of programmable automation systems to the plant safety and PSA is the only method with system analytical view over the safety. This report discusses the applicability of PSA methodology (fault tree analyses, failure modes and effects analyses) in the analysis of programmable automation systems. The problem of how to decompose programmable automation systems for reliability modeling purposes is discussed. In addition to the qualitative analysis and structural reliability modeling issues, the possibility to evaluate failure probabilities of programmable automation systems is considered. One solution to the quantification issue is the use of expert judgements, and the principles to apply expert judgements is discussed in the paper. A framework to apply expert judgements is outlined. Further, the impacts of subjective estimates on the interpretation of PSA results are discussed. (orig.) (13 refs.)

  18. Serum PSA and cure perspective for prostate cancer in males with nonpalpable tumor

    Directory of Open Access Journals (Sweden)

    Marcos F. Dall'Oglio

    2005-10-01

    Full Text Available INTRODUCTION: Many studies have shown the association between PSA levels and the subsequent detection of prostate cancer. In the present trial, we have studied the relationship between preoperative PSA levels and clinical outcome following radical prostatectomy in men with clinical stage T1c. MATERIALS AND METHODS: 257 individuals with clinical stage T1c undergoing retropubic radical prostatectomy were selected in the period from 1991 to 2000. Following surgery, biochemical recurrence-free survival curves were constructed according to PSA levels between 0-4; 4.1-10; 10.1-20 and > 20 ng/mL. RESULTS: Of the total of 257 selected patients, 206 (80% had Gleason scores from 2 to 6 and 51 (20%, presented Gleason scores 7 and 8, as defined by the pathological report from prostate biopsy. There was no biochemical recurrence of disease when the PSA was lower than 4, regardless of Gleason score. Biochemical recurrence-free survival according to PSA between 0-4; 4.1-10; 10.1-20 and > 20 was 100%, 87.6%, 79% and 68.8% for Gleason scores 2-6 and 100%; 79.4%; 40% and 100% for Gleason scores 7-8 respectively. When all individuals were grouped, regardless of their Gleason scores, the probability of biochemical recurrence-free survival was 100%, 65.1%, 53.4% and 72.2% according to PSA between 0-4; 4.1-10; 10.1-20 and > 20 ng/mL respectively. CONCLUSION: Non-palpable prostate cancer presents higher chances of cure when the PSA is inferior to 4 ng/mL.

  19. IAEA work with guides for PSA quality

    International Nuclear Information System (INIS)

    Hellstroem, Per

    2004-09-01

    IAEA has a project on development of a TECDOC 'PSA Quality for Various Applications'. The project develops the guidance document in stages with intermediate meetings with exchange of ideas, thoughts and experience. Draft versions are being produced successively. The objective with the project is to use attributes to describe the quality of different elements of a PSA (Analysis of initiating events, accident progression, system, data, human reliability, etc) making the PSA suitable for application in various risk informed activities. Two of the meetings in this project took place in February 2004 and in July 2004. The February meeting discussed different aspects of PSA quality in relation to applications and a draft of the TECDOC was reviewed. The meeting made recommendations for preparation of a final document and set priorities for further work in the area. The July meeting elaborated the document further in a small working group and a new draft version was prepared. A final version is expected to be published during 2005. The project has come to the conclusion that it is a limited number of PSA element attributes that are specific for a certain application. Most of the attributes concern plant specificity, realism and level of detail in a general manner, how plant specific is the model, how realistic and how detailed? Many attributes have the characteristic that they are good to have, but not necessarily needed to do the job. This last statement is valid both for a baseline PSA and a PSA application. The IAEA project has identified a limited number of attributes that are necessary to describe characteristics needed for specific applications. The PSA scope needed for a specific application is not covered by the project/document, even though it is obvious that different applications will need different scope or approaches to handle scope limitations. The guidance on performing a PSA available today is old. It is a need to review these guides and update with regard

  20. Workshop on PSA for New and Advanced Reactors

    International Nuclear Information System (INIS)

    2012-01-01

    This workshop was organized by the NEA Working Group on Risk Assessment (WGRISK). The key objective of the workshop was to share the current state-of-the art on the PSA (Probabilistic Safety Assessment) applied for new reactors and advanced reactors. Fifty experts from 13 countries and one international organization (IAEA) participated in the present workshop, and 35 technical papers were presented. The main topics of interest, discussed during the workshop, included the followings: regulatory aspects, risk-informed methods, technical aspects of the PSA for new and advanced reactors, hazards of PSA (internal and external), severe accident/source term/Level 2 PSA, and consequence analysis/Level 3 PSA. Among the technical aspects of the PSA, the assessment of the reliability of passive safety systems appears to be a recurrent issue

  1. Experiences of Uncertainty in Men With an Elevated PSA.

    Science.gov (United States)

    Biddle, Caitlin; Brasel, Alicia; Underwood, Willie; Orom, Heather

    2015-05-15

    A significant proportion of men, ages 50 to 70 years, have, and continue to receive prostate specific antigen (PSA) tests to screen for prostate cancer (PCa). Approximately 70% of men with an elevated PSA level will not subsequently be diagnosed with PCa. Semistructured interviews were conducted with 13 men with an elevated PSA level who had not been diagnosed with PCa. Uncertainty was prominent in men's reactions to the PSA results, stemming from unanswered questions about the PSA test, PCa risk, and confusion about their management plan. Uncertainty was exacerbated or reduced depending on whether health care providers communicated in lay and empathetic ways, and provided opportunities for question asking. To manage uncertainty, men engaged in information and health care seeking, self-monitoring, and defensive cognition. Results inform strategies for meeting informational needs of men with an elevated PSA and confirm the primary importance of physician communication behavior for open information exchange and uncertainty reduction. © The Author(s) 2015.

  2. Prostate MR imaging for patients with elevated serum PSA levels. The clinical value of diffusion-weighted and dynamic MR imaging in cancer screening

    International Nuclear Information System (INIS)

    Tanimoto, Akihiro; Shinmoto, Hiroshi; Kuribayasi, Sachio; Nakashima, Jun; Kohno, Hidaka; Murai, Masaru

    2006-01-01

    The purpose of this study was to evaluate the clinical value of diffusion-weighted imaging (DWI) and dynamic magnetic resonance imaging (MRI) in combination with T 2 -weighted imaging (T 2 W) for the detection of prostate cancer. Eighty-three patients with elevated serum levels of prostate-specific antigen (PSA) (>4.0 ng/mL) were evaluated by T 2 W, DWI, and dynamic MRI at 1.5T prior to needle biopsy. The data from the results of the T 2 W alone (protocol A), combination of T 2 W and DWI (protocol B), and combination of T 2 W+DWI and dynamic MRI (protocol C) were entered into a receiver operating characteristic (ROC) analysis. Prostate cancer was detected by pathology in 44 of 83 patients. The sensitivity, respective specificity, accuracy, and Az (the area under the ROC curve) for the detection of prostate cancer were 73%, 54%, 64%, and 0.71 in protocol A; 84%, 85%, 84%, and 0.90 in protocol B; and 95%, 74%, 86%, and 0.97 in protocol C. The sensitivity, specificity, and accuracy were significantly different among the 3 protocols (p 2 W, DWI, and dynamic MRI may be valuable for detecting prostate cancer and avoiding unnecessary biopsy. (author)

  3. High grade intraepithelial neoplasia of prostate is associated with values of prostate specific antigen related parameters intermediate between prostate cancer and normal levels

    Directory of Open Access Journals (Sweden)

    Nermina Obralic

    2011-11-01

    Full Text Available High grade prostatic intraepithelial neoplasia (HGPIN is widely regarded as the precancerous. The aim of this study was to determine PSA related parameters in patients with initial PSA values 2-10 ng/mL and diagnosis of HGPIN without finding carcinoma at the time of their first needle biopsy. Study groups consisted of 100 men who were diagnosed HGPIN, 84 with cancer and 183 with benign hyperplasia on first biopsy of prostate. Total PSA and free PSA were measured and ratio free/total PSA and PSA density calculated. Mean values of these parameters were compared, and receiver operating characteristic curves were used for comparison of PSA related parameters to discriminate groups of patients. Total PSA, free PSA level and PSA density in patients with HGPIN (6.388 ng/mL did not differ significantly compared to prostate carcinoma (6.976 ng/mL or benign prostatic hyperplasia (6.07 ng/mL patients. Patients with HGPIN had significantly higher ratio free/total PSA than those with prostate carcinoma (0.168 vs 0.133, but significantly lower than patients with benign prostatic hyperplasia (0.168 vs 0.185. Ratio of free/total PSA significantly discriminate HGPIN from prostate carcinoma with sensitivity 84.52 and specify 45.00 at cut-off point of ≤ 0.18. Values of PSA, free PSA and ratio free/total PSA in cases of HGPIN appear to be intermediate between prostate cancer and normal levels. Ratio of free/total PSA may help in decision to repeat biopsies in the presence of HGPIN on biopsy, without concomitant prostate cancer, in patients suitable for curative treatment, with normal digito-rectal examination and trans-rectal sonography.

  4. The Prostate Health Index in predicting initial prostate biopsy outcomes in Asian men with prostate-specific antigen levels of 4-10 ng/mL.

    Science.gov (United States)

    Ng, C F; Chiu, Peter K F; Lam, N Y; Lam, H C; Lee, Kim W M; Hou, Simon S M

    2014-04-01

    To investigate the role of the Prostate Health Index (phi) in prostate cancer (PCa) detection in patients with a prostate-specific antigen (PSA) level of 4-10 ng/mL receiving their first prostatic biopsy in an Asian population. This was a retrospective study of archived serum samples from patients enlisted in our tissue bank. Patients over 50 years old, with PSA level of 4-10 ng/mL, a negative digital rectal examination, and received their first prostatic biopsy between April 2008 and April 2013, were recruited. The serum sample collected before biopsy was retrieved for the measurement of various PSA derivatives and the phi value was calculated for each patient. The performance of these parameters in predicting the prostatic biopsy results was assessed. Two hundred and thirty consecutive patients, with 21 (9.13 %) diagnosed with PCa, were recruited for this study. Statistically significant differences between PCa patients and non-PCa patients were found for total PSA, PSA density, [-2]proPSA (p2PSA), free-to-total PSA ratio (%fPSA), p2PSA-to-free PSA ratio (%p2PSA), and phi. The areas under the curve of the receiver operating characteristic curve for total PSA, PSA density, %fPSA, %p2PSA, and phi were 0.547, 0.634, 0.654, 0.768, and 0.781, respectively. The phi was the best predictor of the prostatic biopsies results. At a sensitivity of 90 %, the use of the phi could have avoided unnecessary biopsies in 104 (45.2 %) patients. Use of the phi could improve the accuracy of PCa detection in patients with an elevated PSA level and thus avoid unnecessary prostatic biopsies.

  5. The optimal timing to perform 18F/11C-choline PET/CT in patients with suspicion of relapse of prostate cancer: trigger PSA versus PSA velocity and PSA doubling time.

    Science.gov (United States)

    Calabria, Ferdinando; Rubello, Domenico; Schillaci, Orazio

    2014-12-09

    In the present short communication we considered the main publications focused on trigger prostate-specific antigen (PSA) and PSA kinetics that systematically compared 18F to 11C-choline PET/CT in order to establish the optimal time to perform choline PET/CT in relation to the trigger values and velocity, as well as doubling time of PSA serum levels.

  6. In-vitro radioimmunoassay of prostate specific antigen (PSA) for the screening and management of prostate cancer in Lebanon

    International Nuclear Information System (INIS)

    El Ezzi, Asmahan; El Ahmadiyeh, Nabil

    2004-01-01

    (Immunoradiometric) technology, using coated tubes was used for both total and free PSA assays. Kits from Immunotech, France were generously purchased by the IAEA, under the Regional project RAW 6/007. A total of 4557 men were screened during the period from September 2000 to end of 2002. Of these 29 men were found to have prostate cancer. The total PSA level for these cases was between 3.2 - 73 ng/ml. 4 cases though were highly suspicious, but they still needed more investigations for the final diagnosis. Among the 29 cancer patients, 2 men died as they had extensive metastases when screening was done and 3 were detected early and are under treatment. The results obtained from our study showed that the incidence of prostate cancer is high in Lebanon. The use of radioimmunoassay technology for PSA assays in the screening for prostate cancer in the Lebanese was of great benefit. Now our priority is to increase the awareness of the population about the prostate cancer for its early detection. (author)

  7. Consideration of external hazards and multi-source interactions in the USNRC's site level 3 PSA project

    International Nuclear Information System (INIS)

    Siu, N.; Stutzke, M.; Drouin, M.; Tobin, K.; Coyne, K.; Kuritzky, A.

    2014-01-01

    U.S.NRC launched a project in September 2011 to evaluate the total risk at a selected reference NPP (the Vogtle plant) according to the entire initiators, including external hazards. The scope of this risk evaluation was given as 'reactor in all operational modes, including full power, low power and shutdown modes, spent fuel pool and dry cask storage, where all the internal and external hazards are considered'. As part of this study, an Integrated Site Risk Analysis (ISRA) addressing the combinations of and interactions between the different sources of radiological risk (reactors, spent fuel pool (SFP), dry casks) is underway. A number of modeling and implementation challenges were identified. The former include the problem of combinatorial explosion associated with the need to treat multiple sources over extended periods of time

  8. A case report of monitoring PSA level changes in two prostate cancer patients treated with Mountain Ginseng Pharmacopuncture and Sweet Bee Venom along with western anticancer therapy

    Directory of Open Access Journals (Sweden)

    Yeonhee Lee

    2011-12-01

    Full Text Available Objectives: The purpose of this report is to find out how Mountain Ginseng Pharmacopuncture(MGP and Sweet Bee Venom(SBV treatments are effective on prostate cancer patients by monitoring Prostate specific antigen(PSA values. Methods: We treated two prostate cancer patients with MGP and SBV from October 2008 to April 2011. One patient had localized prostate cancer, the other was in the terminal stage of prostate cancer with lung and bone metastasis and both had been receiving western anticancer therapy. We had monitored the changes of PSA value. Results: In case 1, MGP and SBV treatments seemed to be helpful in preventing the recurrence of localized prostate cancer. In case 2, PSA value was decreased by MGP treatment. Conclusions: It is conceivable that MGP and SBV are effective treatments for patients with prostate cancer.

  9. UV/EB curable psa's

    International Nuclear Information System (INIS)

    Glotfelter, C.A.

    1995-01-01

    The author describe both water-based and 100% solids UV/EB curable PSA's (Pressure Sensitive Adhesives) and their properties. A new acrylate monomer, ethoxylated nonyl phenol acrylate, has great utility in the formulation of water-based PSA's

  10. Reduced total serum bilirubin levels are associated with ulcerative colitis.

    Directory of Open Access Journals (Sweden)

    Kathleen M Schieffer

    Full Text Available Chronic inflammation associated with inflammatory bowel disease (IBD results in increased oxidative stress that damages the colonic microenvironment. Low levels of serum bilirubin, an endogenous antioxidant, have been associated with increased risk for Crohn's disease (CD. Therefore, the aim of this study was to examine whether total serum bilirubin levels are associated with ulcerative colitis (UC. We identified a retrospective case-control population (n = 6,649 from a single tertiary care center, Penn State Hershey Medical Center (PSU and a validation cohort (n = 1,996 from Virginia Commonwealth University Medical Center (VCU. Cases were age- and sex-matched to controls (PSU: CD n = 254, UC n = 187; VCU: CD n = 233, UC n = 124. Total serum bilirubin levels were obtained from de-identified medical records and segregated into quartiles. Logistic regression analysis was performed on each quartile of total serum bilirubin compared to the last quartile (highest bilirubin levels to determine the association of total serum bilirubin with UC. Similar to CD patients, UC patients demonstrated reduced levels of total serum bilirubin compared to controls at PSU and VCU. The lowest quartile of total serum bilirubin was independently associated with UC for the PSU (OR: 1.98 [95% CI: 1.09-3.63] and VCU cohorts (OR: 6.07 [95% CI: 3.01-12.75]. Lower levels of the antioxidant bilirubin may reduce the capability of UC patients to remove reactive oxygen species leading to an increase in intestinal injury. Therapeutics that reduce oxidative stress may be beneficial for these patients.

  11. Perspectives of Living PSA in NPP Krsko

    International Nuclear Information System (INIS)

    Vrbanic, I.; Kastelan, M.

    1996-01-01

    Nuclear power plant Krsko has completed the Level 1/Level 2 Probabilistic Safety Analysis (PSA) for internal initiating events and is in the process of completing the same for the external initiators. The analysis completed up to now has provided a valuable insight into a plant risk profile. In NPP Krsko there is a plan to use the PSA model as a permanent tool for the risk based applications and incorporate it into a decision making process. In order to achieve this there is a need to permanently maintain the PSA model in a manner that it reflects both the plan configuration/design at a time point and the operational experience up to the time point. All the activities aimed toward keeping the PSA model up-to-dated in this sense are usually referred to as a Living PSA (LPSA) program. NPP Krsko is in the process of defining and proceduralizing a LPSA program that would be plant specific and based on known world practices. Further, in order to be suitable for risk based applications the PSA model must be flexible in a sense that modifications to the base case model may be done easily and requantifications performed quickly as to evaluate various conditions imposed by real or hypothetical situations. NPP Krsko PSA model has been based on licensing type software. The requirements specified above dictate the transfer of the overall model to an application oriented software of newer generation with larger capabilities. The transfer becomes a part of a mentioned ongoing effort aimed at establishing LPSA model and concept. The paper present this effort and the perspectives of LPSA concept and risk based applications in NPP Krsko. (author)

  12. Use of PSA for improving the safety of French PWRs

    International Nuclear Information System (INIS)

    Lanore, J.M.; Chambon, J.L.

    1994-06-01

    Two French PWR Probabilistic Safety Assessment (PSA) studies were conducted for the standardized PWR series of 900 and 1300 MWe. Both PSA 900 and PSA 1300 are level 1 PSAs, that means their objective is the evaluation of core meltdown frequency. These studies have some specific features, in particular the treatment of shutdown conditions, the treatment of long term post-accidental situations, and a wide use of French experience feedback. The PSAs are used for safety improvements of the French PWRs. Following the PSA results, several modifications to plants concerning the dominant sequences were decided. (R.P.). 2 refs., 4 figs

  13. PSA testing anxiety, psychological morbidity, and PSA utility in the management of prostate cancer.

    OpenAIRE

    Micsunescu, Anamaria Elia

    2017-01-01

    Anecdotal reports from urologists and medical oncologists have suggested that patients with prostate cancer (PCa) often present with anxiety related to ongoing monitoring of their PSA levels as part of their disease management. The purpose of the current study, therefore, was to determine the prevalence and severity of prostate specific antigen (PSA) testing anxiety in a population of patients with either localised or metastatic PCa living in Australia. Other aspects of psychological morbidit...

  14. Low Power Shutdown PSA for CANDU Type Plants

    Energy Technology Data Exchange (ETDEWEB)

    Bae, Yeon Kyoung; Kim, Myung Su [KHNP CRI, Daejeon (Korea, Republic of)

    2016-10-15

    KHNP also have concentrated on full power PSA. Some recently constructed OPR1000 type plants and APR1400 type plants have performed the low power and shutdown (LPSD) PSA. The purpose of LPSD PSA is to identify the main contributors on the accident sequences of core damage and to find the measure of safety improvement. After the Fukushima accident, Korean regulatory agency required the shutdown severe accident management guidelines (SSAMG) development for safety enhancement. For the reliability of SSAMG, KHNP should develop the LPSD PSA. Especially, the LPSD PSA for CANDU type plant had developed for the first time in Korea. This paper illustrates how the LPSD PSA for CANDU type developed and the core damage frequency (CDF) is different with that of full power PSA. KHNP performed LPSD PSA to develop the SSAMG after the Fukushima accidents. The results show that risk at the specific operation mode during outage is higher than that of full power operation. Also, the results indicated that recovery failure of class 4 power at the POS 5A, 5B contribute dominantly to the total CDF from importances analysis. LPSD PSA results such as CDF with initiating events and POSs, risk results with plant damage state, and containment failure probability and frequency with POSs can be used by inputs for developing the SSAMG.

  15. Tools for PSA reviews

    International Nuclear Information System (INIS)

    Linden, J. von

    1998-01-01

    It is desirable to have a uniform and competent procedure for the review of PSAs which are performed within the framework of the Periodic Safety Review of German Nuclear Power Plants. Guidelines for the review process should therefore be evaluated within task A. 1 of project SR 2096. The basis for this work is the experience and knowledge within GRS derived from PSA-related work and from several review projects as well as the German PSA Guide with its appendices. Furthermore, the review processes in the USA, Switzerland and Sweden and the Guidelines for the International Peer Review Service (IPERS Guidelines) were utilized. As a result, recommendations are given for the review process, with individual recommendations concerning the organization of the review, task allocation between the reviewers, interface problems, assessment criteria, the scope and depth of the review as well as the supporting documents. An additional result are checklists for the technical elements of the PSA, which are listed to facilicate the review work. It is not the intention of this report to work out complete review guidelines. Its aims is rather more to give recommondations and support for the review in addition to what can be derived from the existing documents that should be used for the review. The recommendations reflect the view of GRS and go beyond the statements given in the German PSA Guide (Leitfaden Probabilistische Sicherheitsanalyse /PSUe97/) in some points. (orig.) [de

  16. Binge Drinking PSA (:60)

    Centers for Disease Control (CDC) Podcasts

    This PSA is based on the October, 2010 CDC Vital Signs report which indicates that drinking too much, including binge drinking, causes more than 79,000 deaths in the U.S. each year and is the third leading preventable cause of death.

  17. Introduction to PSA applications

    International Nuclear Information System (INIS)

    Evans, M.G.K.

    1997-01-01

    The aim of this presentation is to show how the PSA can be used to determine the risk impact of the various deterministic processes for plant design or operational changes, and the evaluation of off normal events that occurred at the plant. The presentation is divided into the following topics: Identification of issues; Tasks/element identification; Modelling changes; Data changes. 6 figs

  18. Babesiosis PSA (:60)

    Centers for Disease Control (CDC) Podcasts

    2012-04-25

    This 60 second PSA describes babesiosis, a preventable and treatable tickborne disease, including the signs and symptoms of infection and ways to prevent it.  Created: 4/25/2012 by Center for Global Health, Division of Parasitic Diseases and Malaria.   Date Released: 4/26/2012.

  19. Optimum modellings of atmospheric diffusion of radioactive effluents and exposure doses in the accident consequence assessment (Level 3 PSA)

    International Nuclear Information System (INIS)

    Kim, Byung Woo; Lee, Young Bok; Han, Moon Hee; Kim, Eun Han; Suh, Kyung Suk; Hwang, Won Tae

    1992-12-01

    Atmospheric diffusion and exposure strongly dependent on the environment were firstly considered in the full spectrum of accident consequence assessment to establish based on Korean conditions. An optimum weather category based on Korean climate and site-specific meteorology of Kori region was established by statistical analysis of measured data for 10 years. And a trajectory model was selected as the optimal one in the ACA by reviewing several existing diffusion models. Following aspects were considered in this selection as availability of meteorological data, ability to treat the change to wind direction, easy applicability of the model, and restriction of CPU time and core memory in current computers. Numerical integration method of our own was selected as the optimal dose assessment tool of external exposure. Unit dose rate was firstly computed with this method as the function of energy level of radionuclide, size of lattice, and distance between source and receptor, and then the results were rearranged as the data library for the rapid access to the ACA run. Dynamic ecosystem modelling has been done in order to estimate the seasonal variation of radioactivity for the assessment of ingestion exposure, considering Korean ingestion behavior, agricultural practice and the transportation. There is a lot of uncertainty in a countermeasure model due to the assumed values of parameters such as fraction of population with different shielding factor and driving speed. A new countermeasure model was developed using the concept of fuzzy set theory, since it provided the mathematical tools which could characterize the uncertainty involved in countermeasure modelling. (Author)

  20. Prostate-Specific Antigen Velocity Before and After Elimination of Factors That Can Confound the Prostate-Specific Antigen Level

    International Nuclear Information System (INIS)

    Park, Jessica J.; Chen, Ming-Hui; Loffredo, Marian; D’Amico, Anthony V.

    2012-01-01

    Purpose: Prostate-specific antigen (PSA) velocity, like PSA level, can be confounded. In this study, we estimated the impact that confounding factors could have on correctly identifying a patient with a PSA velocity >2 ng/ml/y. Methods and Materials: Between 2006 and 2010, a total of 50 men with newly diagnosed PC comprised the study cohort. We calculated and compared the false-positive and false-negative PSA velocity >2 ng/ml/y rates for all men and those with low-risk disease using two approaches to calculate PSA velocity. First, we used PSA values obtained within 18 months of diagnosis; second, we used values within 18 months of diagnosis, substituting the prebiopsy PSA for a repeat, nonconfounded PSA that was obtained using the same assay and without confounders. Results: Using PSA levels pre-biopsy, 46% of all men had a PSA velocity >2 ng/ml/y; whereas this value declined to 32% when substituting the last prebiopsy PSA for a repeat, nonconfounded PSA using the same assay and without confounders. The false-positive rate for PSA velocity >2 ng/ml/y was 43% as compared with a false-negative rate of PSA velocity >2 ng/ml/y of 11% (p = 0.0008) in the overall cohort. These respective values in the low-risk subgroup were 60% and 16.7% (p = 0.09). Conclusion: This study provides evidence to explain the discordance in cancer-specific outcomes among groups investigating the prognostic significance of PSA velocity >2 ng/ml/y, and highlights the importance of patient education on potential confounders of the PSA test before obtaining PSA levels.

  1. Plasma Total Homocysteine (tHcy) Levels in Healthy Nigerian ...

    African Journals Online (AJOL)

    Establishment and stratification of reference values for a laboratory area of practice enhances the test result interpretation and sensitivity. Plasma total homocysteine (tHcy) is a metabolite of methionine which is dependent on vitamin B6, B12 and folate as co-factors. Plasma level (Hyperhomocysteinemia) is influenced by ...

  2. Decreased total antioxidant levels and increased oxidative stress in ...

    African Journals Online (AJOL)

    Background: Chronic hyperglycaemia in diabetes mellitus leads to increased lipid peroxidation in the body, followed by the development of chronic complications due to oxidative stress. Objective: The aim of this study was to compare total antioxidant (TAO) levels and oxidative stress in type 2 diabetes mellitus (T2DM) ...

  3. Total oxidant status, total antioxidant capacity and ischemia modified albumin levels in children with celiac disease.

    Science.gov (United States)

    Sayar, Ersin; Özdem, Sebahat; Uzun, Gülbahar; İşlek, Ali; Yılmaz, Aygen; Artan, Reha

    2015-01-01

    In our study, we aimed to investigate ischemia modified albumin (IMA) as an oxidative stress marker, as well as other oxidant and antioxidant markers that have not been evaluated in children with celiac disease. A total of 37 pediatric patients who were diagnosed with celiac disease (CD) and 29 healthy children were enrolled in this prospective study. We evaluated the IMA, total oxidant status, total antioxidant capacity, sulfhydryl, and advanced oxidation protein products in all of the subjects. We also compared the levels at the time of the diagnosis, and following a gluten-free diet (GFD) in the children with CD. While the IMA and the other oxidant marker levels were significantly higher in the patient group compared to the control group, the antioxidant marker levels were found to be significantly lower in the patient group, compared to the control group. We also determined that the tissue transglutaminase IgA showed a highly positive correlation, and that the IMA showed a moderately positive correlation with the Marsh-Oberhuber histopathological stage. Additionally, the IMA and other oxidant marker levels were significantly lower, while the antioxidant marker levels were significantly higher after the GFD, compared to the pre-diet period. We detected that oxidative stress played a role in the pathogenesis of CD, and that this could be evaluated using oxidative stress markers, which would regress after the GFD. We also detected that IMA is a marker that shows a correlation with the histopathological stage, and may be used in the diagnosis.

  4. PSA in operator training

    International Nuclear Information System (INIS)

    Nos, V.; Faig, J.; Plesa, P.; Delgado, J. L.

    2000-01-01

    The systematic approach to training is internationally accepted as the best method to achieve and maintain the qualification and competence of power plant personnel and to guarantee the quality of their training. Following the recommendations and guidelines of international organisations competent in the field, TECNATOM SA has developed projects based on the systematic approach to training for all Spanish nuclear power plants. One of the latest projects was the systematic approach to training developed for the operation personnel of ASCO Nuclear Power Plant. In this case, certain results of the Probabilistic Safety Analysis (PSA) which complement the systematic safety and reliability criteria of the systematic approach to training process have been incorporated in the traditional processes of work and task analysis and training plan design. This incorporation provides the training manager with additional criteria based not only on safety aspects obtained through the statistical treatment of considerations of skilled technical personnel (operators, operation chief supervisors, etc), but also on the independent criterion of the PSA. The inclusion of this approach basically affects all systematics in two of its stages: During the selection process of operating practices in SMR or SGI, the possible scenarios have been associated with all those situations where human actions which lead to an initiating event or human actions to mitigate an initiating event, may take place, as defined in the PSA. During the scenario development process, the instruments involved in the performance of human actions which originate or mitigate an event taking place have been identified. This pakes it possible to reconcile the scenario event sequence with the sequence considered in the PSA study, as the most likely to provoke a more serious accident. The incorporation of these PSA results contributes to the strengthening of safety aspects in training in an objective way, and confirms that

  5. Evaluation of PCA3 and multiparametric MRI’s: collective benefits before deciding initial prostate biopsy for patients with PSA level between 3-10ng/mL

    Directory of Open Access Journals (Sweden)

    Sezgin Okcelik

    2016-06-01

    Full Text Available ABSTRACT Objective To analyze the contribution of multiparametric MRI and PCA3 assay, pre- decision of initial biopsy in PSA level between 3-10 ng/mL patients with normal digital rectal examination(DRE. Materials and Methods PSA level 3-10 ng/mL ,patients, with normal DRE results and no previous prostate biopsy history, were included in this study. Each patient underwent multiparametric MRI one week before biopsy. Urine sample taking for PCA3 examination preceded the biopsy. Systematic and targeted biopsies were conducted. Patients with high PSA levels were seperated into two groups as: high PCA3 scored and low PCA3 scored. Then each group was divided into two sub-groups as: MRI lesion positive and negative. Tumor incidence, positive predictive values(PPV and negative predictive values(NPV were calculated. Results 53 patients were included between February 2013 and March 2014.Mean age 61.22 ± 1.06. Mean PSA value 5.13 ± 0.19 ng / mL. Mean PCA3 score 98.01 ± 23.13 and mean prostate size was 48.96 ± 2.67 grams. Fourty nine patients had both PCA3 score and multiparametric MRI. The PCA3’s PPV value was 58.33%. If multiparametric MRI lesions are added to high PCA3 scores , the PPV appears to elevate to 91.66%. NPV of PCA3 was 96%. NPV was 95% when there was no lesion in the multiparametric MRI with low PCA3 scores. Sensitivity was 91.66% , specificity was 95% respectively. Conclusion Adding multimetric MRI can also support biopsy decision for patients with high PCA3 value. When PCA3 value is low, patients can be survailled without any need to take a MRI.

  6. Free and total prostate specific antigen in benign prostate hyperplasia and prostate cancer

    International Nuclear Information System (INIS)

    Naz, S.; Ahmad, S.; Akhtar, M.W.; Ghafoor, F.; Butt, N.S.

    2004-01-01

    To record the levels of PSA in the sera of prostate cancer (CaP) and benign prostatic hyperplasia (BPH) cases. Free PSA/total PSA as percentage was also calculated in order to evaluate its utility in differentially diagnosing BPH and CaP. Material and Methods: A group of 108 male subjects, including one-third of each of biopsy-confirmed prostate cancer , BPH cases and asymptomatic controls of matching age were studied. PSA and Free PSA were determined by ELISA using commercially available assay kits. Results: Mean PSA was found to be highest in CaP cases (41.9 plus minus 38.7 ng/ml), lower in the BPH cases (13.5 plus minus 10.5 ng/ml), while it was lowest in the control subjects (5.7 plus minus 4.4 ng/ml). Moreover, it was observed that a majority of the CaP cases had serum PSA >20 ng/ml, 50% of BPH cases had serum PSA in the 'gray zone' (4.1-20 ng/ml), while majority of controls had serum PSA in the 'normal' range (0 -4 ng/ml). Using a free-PSA 'cut-off' of 18% to differentiate between benign and malignant prostate enlargement, it was found that 80% of the CaP cases had F/T% 18. The percent free-PSA test to differentially diagnose BPH and CaP in the 'gray zone' was found to have a sensitivity of 86% and a specificity of 94%. Conclusion: Using a cutoff of 18%, the free-PSA test significantly improved the differential diagnosis of BPH and CaP in the 'gray zone' as compared to the use of total PSA alone in the study group. (author)

  7. A Preliminary Fire PSA on PGSFR

    International Nuclear Information System (INIS)

    Kim, Kilyoo; Han, Sanghoon; Lee, KwiLim

    2017-01-01

    A Prototype Generation IV Sodium Fast Reactor (PGSFR) is under design with defense in depth concept with active, passive, and inherent safety features to acquire a design approval for PGSFR from Korean regulatory authority by around 2017. A preliminary fire PSA on PGSFR is done in 2016 and a final fire PSA of PGSFR will be done in 2017. The characteristics of the preliminary fire PSA on PGSFR are described in this paper. Since PGSFR is very safe reactor, it is not bad approach to use a conservative assumption in the preliminary PSA. In addition, several drawings including cable routing are not yet issued, a conservative calculation for CDF is performed. As shown in Table 2, the CDF caused by the fire in the control room takes 89% portion of total CDF. Thus, a detailed fire modeling for control room is necessary for the final fire PSA on PGSFR. Also, the increased ignition frequency due to sodium leak would be derived by considering the sodium piping complexity in the final fire PSA on PGSFR. The 4th column of Table 2 is derived the 3rd column by multiplying the factor (592/1177). The 5th column is the ignition frequency caused by the sodium leak. The 6th column is derived by summing the 4th column and the 5th column. The 7th column is the CDF portion of each fire area. The control room (fire area F-A404A) is the most important area since the control room fire takes 89% portion of total CDF.

  8. Enlarged level-1 PSA in regard to assessment of cross-cutting effects of hazards and consideration of their uncertainties for a KONVOI type PWR reference plant

    International Nuclear Information System (INIS)

    Haider, C.; Hofer, E.; Kloos, M.; Kuntze, W.; Liemersdorf, H.; Roewekamp, M.; Schwinges, B.; Tuerschmann, M.; Brenig, H.W.; Sommerfeld, H.

    2001-01-01

    In the frame of supporting BMU regarding generic questions concerning probabilistic safety analyses for nuclear power plants as well as regarding evaluation of nuclear specific standards and guidelines the significant contributions to damage states resulting from plant internal and external hazards had to be estimated for a German Konvoi type PWR reference plant. Furthermore, the suitability of the available methods for assessing these hazards should be checked. In the report presented hereafter, only the plant internal hazard Fire out of all the hazards to be considered was probabilistically analysed in detail First of all, screening analyses were carried out for identifying relevant plant areas and to assess their respective efficiency for a proper selection procedure. For a selected, plant area identified to be relevant (area of the cable distributions inside the reactor containment) an indepth analysis was performed. This analysis included all the steps of the probabilistic assessment, starting from the estimation of the fire occurrence frequency, followed by investigations on the fire effects and fire propagation, up to the determination of the fire induced failure probabilities of safety related equipment including the consequences on systems. In addition, the analyses contained particular uncertainty and sensitivity studies, for which aleatoric and epistemic uncertainties were distinguished. As a result of the screening analyses as well as of the in-depth investigations regarding the fire hazard, no significant contributions for the total frequencies for system, core, or plant damage states have been found. In this context, it has to be noticed that the study presented hereafter does not cover a complete fire PSA. With respect to assessing the available methods it has been found that improvements concerning the screening process as well as concerning the probabilistic fire event tree analyses are necessary. With regard to further hazards, a site specific

  9. Early detection of prostate cancer in Syria using T.PSA and F.PSA

    International Nuclear Information System (INIS)

    Adel, M.; Abu Daher, D.

    2009-12-01

    The aim of the current study is performing an initial prostate cancer screening test using PSA and F PSA tumour markers. A total of 3000 men in 40-75 years of age were participated in this study. Demographic and clinical data for subjects were collected by the programme staff. Total PSA and free PSA assays were determined using the ImunoTech total and free PSA assay kits, based on IRMA technique (kindly provided by the International Atomic Energy Agency). Criteria for participating in this study included : 1) men of age 50-75 (men of age as low as 40 were included in case of positive family history). 2) No previous history of prostate cancer. The following parameters were followed to refer the suspicious cases to a specialized hospital specific tests: 1)PSA>3 ng/ml . 2)High PSA value according to the participant age group. 3) Low F/TPSA ratio. In the hospital the following tests were performed:1) Complete clinical exam including DRE.2)TRUS in some cases.3) Biopsy for highly suspicious cases. 4)The low suspicious cases were retested in six months. Out of 338 cases referred to a specialized hospital, 264 cases were shown prostatic benign prostatic hyperplasia (BPH),while 36 cases proved to be prostatic cancer. However, the contact was lost in 36 cases because of changing the phone number or travelling outside the country . The detection rate of prostate cancer among all participating cases in this study was 1.2%, while this ratio was 10.7% among the referred cases. F/TPSA ratio has shown a good ability to discriminate between prostate cancer and benign prostatic hyperplasia. (author)

  10. NPP Krsko Living PSA Concept

    International Nuclear Information System (INIS)

    Vrbanic, I.; Spiler, J.

    2000-01-01

    NPP Krsko developed PSA model of internal and external initiators within the frame of the Individual Plant Examination (IPE) project. Within this project PSA model was used to examine the existing plant design features. In order to continue with use of this PSA model upon the completion of IPE in various risk-informed applications in support of plant operation and evaluations of design changes, an appropriate living PSA concept needed to be defined. The Living PSA concept is in NPP Krsko considered as being a set of activities pursued in order to update existing PSA model in a manner that it appropriately represents the plant design, operation practice and history. Only a PSA model which is being updated in this manner can serve as a platform for plant-specific risk informed applications. The NPP Krsko living PSA concept is based on the following major ponts. First, the baseline PSA model is defined, which is to be maintained and updated and which is to be reference point for any risk-informed application. Second, issues having a potential for impact on baseline PSA model are identified and procedure and responsibilities for their permanent monitoring and evaluation are established. Third, manner is defined in which consequential changes to baseline PSA model are implemented and controlled, together with associated responsibilities. Finally, the process is defined by which the existing version of baseline PSA model is superseded by a new one. Each time a new version of baseline PSA model is released, it would be re-quantified and the results evaluated and interpreted. By documenting these re-quantifications and evaluations of results in a sequence, the track is being kept of changes in long-term averaged risk perspective, represented by long-term averaged frequencies of core damage and pre-defined release categories. These major topics of NPP Krsko living PSA concept are presented and discussed in the paper. (author)

  11. Performance indicators at Embalse NPP: PSA and safety system indicators based on PSA models

    International Nuclear Information System (INIS)

    Fornero, D.A.

    2001-01-01

    Several indicators have been implemented at Embalse NPP. The objective was selecting some representative parameters to evaluate the performance of both the plant and the personnel activities, important for safety. A first set of indicators was defined in accordance with plant technical staff criteria. A complementary set of them was addressed later based on WANO guidance. This report presents the set of indicators used at Embalse NPP, centering the description to related to safety systems performance indicators (SSPI). Some considerations are done about the calculation methods, the need for aligning and updating their values following Embalse Probabilistic Safety Assessment (PSA) development, and some pros and cons of using the PSA model for getting systems indicators. Owing to the fact that PSA ownership by utilities is also a subject of the meeting, some characteristics of the organization of the PSA Project are described at the beginning of the report. At Embalse NPP a Level 1 PSA has been developed under the responsibility of its own plant and with an important contribution from the IAEA. PSA was developed at the site, conducting this to a study strongly interactive with the station staff. (author)

  12. Whooping Cough PSA (:30)

    Centers for Disease Control (CDC) Podcasts

    2015-01-22

    This 30 second PSA encourages pregnant women to get the whooping cough vaccine, called Tdap, during the third trimester of each pregnancy in order to pass antibodies to their babies so they are born with protection against this serious disease.  Created: 1/22/2015 by National Center for Immunization and Respiratory Diseases (NCIRD), Division of Bacterial Diseases (DBD), Meningitis and Vaccine Preventable Diseases Branch (MVPDB).   Date Released: 1/22/2015.

  13. Binge Drinking PSA (:60)

    Centers for Disease Control (CDC) Podcasts

    2010-10-05

    This PSA is based on the October, 2010 CDC Vital Signs report which indicates that drinking too much, including binge drinking, causes more than 79,000 deaths in the U.S. each year and is the third leading preventable cause of death.  Created: 10/5/2010 by Centers for Disease Control and Prevention (CDC).   Date Released: 10/5/2010.

  14. PSA in design of passive/active safety reactors

    International Nuclear Information System (INIS)

    Sato, T.; Tanabe, A.; Kondo, S.

    1995-01-01

    PSAs in the design of advanced reactors are applied mainly in level 1 PSA areas. However, even in level 1 PSA, there are certain areas where special care must be taken depending on plant design concepts. This paper identifies these areas both for passive and active safety reactor concepts. For example, 'long-term PSA' and shutdown PSA are very important for a passive safety reactor concept from the standpoint of effectiveness of a grace period and passive safety systems. External events are also important for an active safety reactor concept. These kinds of special PSAs are difficult to conduct precisely in a conceptual design stage. This paper shows methods of conducting these kinds of special PSAs simply and conveniently and the use of acquired insights for the design of advanced reactors. This paper also clarifies the meaning or definition of a grace period from the standpoint of PSA

  15. Serum total and free carnitine levels in children with asthma.

    Science.gov (United States)

    Asilsoy, Suna; Bekem, Ozlem; Karaman, Ozkan; Uzuner, Nevin; Kavukçu, Salih

    2009-02-01

    Serum carnitine is decreased in recurrent pulmonary infections. We aimed to evaluate serum carnitine levels in asthmatic children. Study group consisted of children with stable asthma and those with acute asthma attacks, while control group included healthy children. Attack severity was determined by the pulmonary score system. Total and free carnitine levels were studied in one blood sample from the control group and stable asthmatics and in two samples from children with acute asthma exacerbation during and after the attack. All the 40 patients in the study group had moderate asthma including 30 with acute attack (13 mild and 17 moderate) and 10 with stable asthma. Carnitine levels were significantly lower in acute attack asthmatics than in the stable asthmatics and controls, while there was no significant difference between the latter two groups. Carnitine levels were not different between asthmatics with mild and moderate attack, and were similar during and after an acute attack. Serum carnitine levels decrease in children with moderate asthma during exacerbation of asthma and shortly thereafter. Further studies are needed to evaluate the effect of carnitine treatment on serum carnitine level.

  16. Total and free thyroid hormone levels in chronic renal failure.

    Directory of Open Access Journals (Sweden)

    Mehta H

    1991-04-01

    Full Text Available The levels of serum total thyroxine (TT4, triiodothyronine (TT3, free T3, (FT3 free T4 (FT4 and thyrotropin (TSH were measured in 127 clinically euthyroid patients with varying grades of chronic renal failure (CRF; and 97 healthy individuals. They were grouped as: Group I containing 93 patients on conservative management; Group II containing 34 patients on regular dialysis therapy; and Group III (normals. Group I patients showed significant decrease in TT3, TT4 and FT3 levels (p less than 0.001 as compared to Group III, whereas FT4 and TSH values in group I were not significantly altered. TT3, TT4 and FT3 levels reduced as the severity of renal damage increased. Variations in TT3, TT4, FT3, FT4 and TSH levels in Group II patients were similar to those in Group I, except for a decrease in TSH levels (p less than 0.05 as compared to normals. Several thyroid function tests are abnormal in CRF patients, however, finding of normal FT4 and TSH levels would indicate functional euthyroid status.

  17. The open PSA standard as a framework for migration of probabilistic models. Experiences with the KKB PSA

    International Nuclear Information System (INIS)

    Becker, G.; Hussels, U.; Epstein, S.; Rauzy, A.; Schubert, B.

    2008-01-01

    In its present state, the open PSA standard is helpful to determine capabilities of PSA approaches, which have been taken into account by those who formulated it. As soon, as tools come up, which can automatically bring a given PSA into the standard form, the data will be accessible by other software tools, which either are supplementary to the original one, or they may act in the context of quality control. Taking into account, that a PSA model represents a value of some two to ten person years (dependent on level of completeness and level of detail), it is important to have the data in a transparent way, which does not depend on proprietary formats, and can thus be used for more purposes than those, which are implemented in given PSA codes. (orig.)

  18. Prostate-specific antigen (PSA) density in the diagnostic algorithm of prostate cancer.

    Science.gov (United States)

    Nordström, Tobias; Akre, Olof; Aly, Markus; Grönberg, Henrik; Eklund, Martin

    2018-04-01

    Screening for prostate cancer using prostate-specific antigen (PSA) alone leads to un-necessary biopsying and overdiagnosis. PSA density is easily accessible, but early evidence on its use for biopsy decisions was conflicting and use of PSA density is not commonly recommended in guidelines. We analyzed biopsy outcomes in 5291 men in the population-based STHLM3 study with PSA ≥ 3 ng/ml and ultrasound-guided prostate volume measurements by using percentages and regression models. PSA density was calculated as total PSA (ng/ml) divided by prostate volume (ml). Main endpoint was clinically significant cancer (csPCa) defined as Gleason Score ≥ 7. The median PSA-density was 0.10 ng/ml 2 (IQR 0.075-0.14). PSA-density was associated with the risk of finding csPCa both with and without adjusting for the additional clinical information age, family history, previous biopsies, total PSA and free/total PSA (OR 1.06; 95% CI:1.05-1.07 and OR 1.07, 95% CI 1.06-1.08). Discrimination for csPCa was better when PSA density was added to a model with additional clinical information (AUC 0.75 vs. 0.73, P PSA-density. Omitting prostate biopsy for men with PSA-density ≤0.07 ng/ml 2 would save 19.7% of biopsy procedures, while missing 6.9% of csPCa. PSA-density cutoffs of 0.10 ng/ml 2 and 0.15 ng/ml 2 resulted in detection of 77% (729/947) and 49% (461/947) of Gleason Score ≥7 tumors. PSA-density might inform biopsy decisions, and spare some men from the morbidity associated with a prostate biopsy and diagnosis of low-grade prostate cancer.

  19. PSA results and trends for Spain's NPPs

    International Nuclear Information System (INIS)

    Carretero, J.A.

    1993-01-01

    The Spain regulatory authority CSN demanded performance of PSA for all Spain nuclear power plants. The specific data analysis carried out as a part of the PSA has contributed to the realistic view on the results which could be achieved by the PSA. The main characteristics of the PSA in Spain and PSA trends in the development are presented in the paper

  20. Implementation guidelines for seismic PSA

    International Nuclear Information System (INIS)

    Coman, Ovidiu; Samaddar, Sujit; Hibino, Kenta; )

    2014-01-01

    The presentation was devoted to development of guidelines for implementation of a seismic PSA. If successful, these guidelines can close an important gap. ASME/ANS PRA standards and the related IAEA Safety Guide (IAEA NS-G-2.13) describe capability requirements for seismic PSA in order to support risk-informed applications. However, practical guidance on how to meet these requirements is limited. Such guidelines could significantly contribute to improving risk-informed safety demonstration, safety management and decision making. Extensions of this effort to further PSA areas, particularly to PSA for other external hazards, can enhance risk-informed applications

  1. Generation of monoclonal antibodies against prostate specific antigen (PSA) for the detection of PSA and its purification; Generación de anticuerpos monoclonales contra el antígeno específico de próstata (PSA) para la detección del PSA y su purificación

    Energy Technology Data Exchange (ETDEWEB)

    Acevedo Castro, Boris Ernesto [Centro de Ingeniería Genética y Biotecnología, CIGB, La Habana (Cuba)

    2012-07-01

    The prostate cancer in Cuba is a problem of health (2672 diagnosed cases and 2769 deaths in 2007). Various diagnostic methods have been implemented for the detection and management of this disease, emphasizing among them (PSA) prostate-specific antigen serological determination. At this work was generated and characterized a panel of 11 antibodies (AcMs) monoclonal IgG1 detected with high affinity described major epitopes of the PSA, both in solution and attached to the test plate. From the panel obtained AcMs was the standardization of an essay type ELISA for the detection of serum total PSA (associated and free) equimolar, based on antibody monoclonal CB-PSA.4 in the coating and the CB-PSA.9 coupled with biotin as liner, with a detection limit of 0.15 ng/mL. Similarly, standardized system for detection in serum free PSA, based on the AcMs CB-PSA.4 (coating) and CB-PSA.2 coupled with biotin (liner), with a detection limit of 0.5 ng/mL. Finally, with the purpose of using PSA as standard in trials type ELISA, developed a simple method of inmunopurificación based on the AcM, CB-PSA.2, which was obtained the PSA with a purity exceeding 90%. Immunoassay Centre on the basis of the AcMs panel and the results of this study, developed and recorded two diagnostic systems for the detection of PSA in human serum. (author)

  2. SORCE Level 3 Total Solar Irradiance Daily Average V016

    Data.gov (United States)

    National Aeronautics and Space Administration — The Total Solar Irradiance (TSI) data set SOR3TSID contains the total solar irradiance (a.k.a solar constant) data collected by the Total Irradiance Monitor (TIM)...

  3. The levels of triglyceride and total cholesterol in methamphetamine dependence.

    Science.gov (United States)

    Zhang, Meijuan; Lv, Dezhao; Zhou, Wu; Ji, Lili; Zhou, Beibei; Chen, Han; Gu, Yingying; Zhao, Jiyun; He, Jincai

    2017-04-01

    The serum triglyceride (TG) and total cholesterol (TC) levels have been reported altered in the traditional drug-dependence (such as marijuana and heroin). However, studies assessing the relationships among serum TC, TG, and methamphetamine (MA)-dependence have not been described well. In this study, our aim is to explore the serum TG and TC levels in large sample of MA-dependent patients. A retrospective study was conducted in 938 MA-dependent patients who were recruited between February 2, 2008 and March 11, 2013, with social characteristics and drug-dependence history (duration of MA use, routes of drug administration, and daily dose were collected). Then, the serum levels of TC, TG, glucose (GLU), body mass index (BMI), and blood pressure were measured among the participants. Meanwhile, 985 age- and gender-matched healthy people in the physical examination center were selected as control group. Compared with the control group, significant decreases of TC, TG, GLU, and BMI were observed in MA-dependent patients (P < 0.05). Besides, we found that the daily dose of MA use was associated with TC (β = -0.079, P = 0.015) and the duration of MA use was independently related to BMI (β = -0.071, P = 0.031). This study demonstrated that the levels of TC, TG, GLU, and BMI factors altered in the MA-dependent patients. In addition, there is a negative association between MA dependence and TC and BMI.

  4. Time from first detectable PSA following radical prostatectomy to biochemical recurrence: A competing risk analysis

    Science.gov (United States)

    de Boo, Leonora; Pintilie, Melania; Yip, Paul; Baniel, Jack; Fleshner, Neil; Margel, David

    2015-01-01

    Introduction: In this study, we estimated the time from first detectable prostate-specific antigen (PSA) following radical prostatectomy (RP) to commonly used definitions of biochemical recurrence (BCR). We also identified the predictors of time to BCR. Methods: We identified subjects who underwent a RP and had an undetectable PSA after surgery followed by at least 1 detectable PSA between 2000 and 2011. The primary outcome was time to BCR (PSA ≥0.2 and successive PSA ≥0.2) and prediction of the rate of PSA rise. Outcomes were calculated using a competing risk analysis, with univariable and multivariable Fine and Grey models. We employed a mixed effect model to test clinical predictors that are associated with the rate of PSA rise. Results: The cohort included 376 patients. The median follow-up from surgery was 60.5 months (interquartile range [IQR] 40.8–91.5) and from detectable PSA was 18 months (IQR 11–32). Only 45.74% (n = 172) had PSA values ≥0.2 ng/mL, while 15.16% (n = 57) reached the PSA level of ≥0.4 ng/mL and rising. On multivariable analysis, the values of the first detectable PSA and pathologic Gleason grade 8 or higher were consistently independent predictors of time to BCR. In the mixed effect model rate, the PSA rise was associated with time from surgery to first detectable PSA, Gleason score, and prostate volume. The main limitation of this study is the large proportion of patients that received treatment without reaching BCR. It is plausible that shorter estimated median times would occur at a centre that does not use salvage therapy at such an early state. Conclusion: The time from first detectable PSA to BCR may be lengthy. Our analyses of the predictors of the rate of PSA rise can help determine a personalized approach for patients with a detectable PSA after surgery. PMID:25624961

  5. Prostate-Specific Antigen (PSA) Test

    Science.gov (United States)

    ... Cancer Prostate Cancer Screening Research Prostate-Specific Antigen (PSA) Test On This Page What is the PSA ... parts of the body before being detected. The PSA test may give false-positive or false-negative ...

  6. Total Water Level Fun Facts: The Relative Contribution of Extreme Total Water Levels Along the US West Coast

    Science.gov (United States)

    Serafin, K.; Ruggiero, P.; Stockdon, H. F.

    2016-02-01

    In the fall of 2014, parts of the US West Coast endured some of the highest monthly mean sea level anomalies on record, likely due to the presence of "the blob" (Bond et al., 2015), an anomalously warm water mass in the NE Pacific. However, despite the significantly above average water levels, the coastline experienced only marginal coastal flooding and erosion hazards because the ensuing winter lacked significant storms, underscoring the fact that extreme total water levels (TWLs) are compound events. To better understand how several individual processes combine to cause devastating coastal hazards, we investigate the relative contribution that each component (waves, tides, and non-tidal residuals) has on extreme TWLs on sandy beaches. Water level records along the US West Coast are decomposed into mean sea level, astronomical tide, and non-tidal residuals (NTRs). The NTR is further split into an intra-annual seasonal signal, monthly mean sea level anomalies (inter-annual variability), and meteorological surge. TWL time series are then generated by combining water levels with wave runup, computed using wave data and beach morphology. We use this data-driven, structural function approach to investigate the spatial variability of the relative contribution of each component to the maximum TWL event on record. We also use a probabilistic, full simulation TWL model (Serafin and Ruggiero, 2014) to generate multiple, synthetic TWL records, to explore the relative contribution of each component to extreme TWL return levels. We assess the sensitivity to local beach morphology by computing TWLs for a range of observed beach slopes. Extreme TWLs are higher in Oregon and Washington than in California. Wave runup typically comprises > 50% of the TWL signal, while NTRs often compose < 5%, illustrating the importance wave climate has on the potential for extreme TWLs. While waves are typically larger in the North, California experiences greater contributions to extreme TWLs from

  7. Determination of total mercury in nuts at ultratrace level

    International Nuclear Information System (INIS)

    Silva, Maria José da; Paim, Ana Paula S.; Pimentel, Maria Fernanda; Cervera, M. Luisa; Guardia, Miguel de la

    2014-01-01

    Highlights: • Direct analysis of Hg in nuts has been improved by a previous fat removal. • Comparison of cold vapour atomic fluorescence and direct analysis of Hg in nuts. • Mercury content in tree nuts was determined. - Abstract: Total mercury, at μg kg −1 level, was determined in different types of nuts (cashew nut, Brazil nuts, almond, pistachio, peanut, walnut) using a direct mercury analyser after previous sample defatting and by cold vapour atomic fluorescence spectrometry. There is not enough sensitivity in the second approach to determine Hg in previously digested samples due to the strong matrix effect. Mercury levels in 25 edible nut samples from Brazil and Spain were found in the range from 0.6 to 2.7 μg kg −1 by using the pyrolysis of sample after the extraction of the nut fat. The accuracy of the proposed method was confirmed by analysing certified reference materials of Coal Fly Ash-NIST SRM 1633b, Fucus-IAEA 140 and three unpolished Rice Flour NIES-10. The observed results were in good agreement with the certified values. The recoveries of different amounts of mercury added to nut samples ranged from 94 to 101%. RSD values corresponding to three measurements varied between 2.0 and 14% and the limit of detection and quantification of the method were 0.08 and 0.3 μg kg −1 , respectively

  8. Determination of total mercury in nuts at ultratrace level

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Maria José da, E-mail: maryquimica@yahoo.com.br [Departamento de Química – Universidade Federal Rural de Pernambuco, Rue Dom Manoel de Medeiros s/n. Dois irmãos, 52171-900 Recife, PE (Brazil); Paim, Ana Paula S. [Departamento de Química Fundamental – Universidade Federal de Pernambuco, Cidade Universitária, 50740-550 Recife, PE (Brazil); Pimentel, Maria Fernanda [Departamento de Engenharia Química – Universidade Federal de Pernambuco, Recife, PE (Brazil); Cervera, M. Luisa; Guardia, Miguel de la [Department of Analytical Chemistry, Research Building, University of Valencia, 50th Dr. Moliner Street, E-46100 Burjassot, Valencia (Spain)

    2014-08-01

    Highlights: • Direct analysis of Hg in nuts has been improved by a previous fat removal. • Comparison of cold vapour atomic fluorescence and direct analysis of Hg in nuts. • Mercury content in tree nuts was determined. - Abstract: Total mercury, at μg kg{sup −1} level, was determined in different types of nuts (cashew nut, Brazil nuts, almond, pistachio, peanut, walnut) using a direct mercury analyser after previous sample defatting and by cold vapour atomic fluorescence spectrometry. There is not enough sensitivity in the second approach to determine Hg in previously digested samples due to the strong matrix effect. Mercury levels in 25 edible nut samples from Brazil and Spain were found in the range from 0.6 to 2.7 μg kg{sup −1} by using the pyrolysis of sample after the extraction of the nut fat. The accuracy of the proposed method was confirmed by analysing certified reference materials of Coal Fly Ash-NIST SRM 1633b, Fucus-IAEA 140 and three unpolished Rice Flour NIES-10. The observed results were in good agreement with the certified values. The recoveries of different amounts of mercury added to nut samples ranged from 94 to 101%. RSD values corresponding to three measurements varied between 2.0 and 14% and the limit of detection and quantification of the method were 0.08 and 0.3 μg kg{sup −1}, respectively.

  9. Study of the impact on PSA success criteria of the variability of the initial liquid level in case of the loss of the RHR system accident scenario under mid-loop operating conditions

    International Nuclear Information System (INIS)

    Villanueva, J.F.; Carlos, S.; Martorell, S.; Serradell, V.; Pelayo, F.; Mendizabal, R.; Cirauqui, C.; Sol, I.

    2005-01-01

    Probabilistic safety assessment (PSA) is recognized nowadays as an important tool to support risk-informed decision-making aimed at providing both operational flexibility and plant safety [1]. Experience of current PSA studies shows the importance of some risky scenarios with the plant at low power and shutdown conditions as compared to the accident scenarios with the plant operating at full power. In particular, current low power and shutdown PSA (LPSA) studies shows that the loss of the Residual Heat Removal System (RHRS) transient is one of the most risk-significant events under low power conditions [2]. This accident type is supposed to occur for various plant operating states, of which mid-loop operation represents one of the main contributors [3]. LPSA has widely used methods for thermal-hydraulic analysis that play an important role in determining success criteria of safety-related functions involved to mitigate the severity of accident scenarios with the plant operating in such conditions. Various best estimate thermal-hydraulic analysis codes have been used to analyze the loss of the RHRS during low power and shutdown conditions [4, 5]. It is known that RELAP code can give good results as derived after a number of benchmark exercises using results from experiments at research facilities (e.g. ROSA-IV, BETHSY, PKL). [6] Previous research has shown how thermal-hydraulic phenomena after the loss of the RHRS, e.g. peak reactor coolant system pressure, are sensitive to the initial liquid level at the time of loss of the RHRS [2]. This paper presents the results of the study of the thermalhydraulic analysis of the accident scenarios after the loss of the RHRS under mid-loop conditions paying particular attention to the analysis of the effect of the variability of the initial liquid level on the success criteria of the safety-related functions considered in a typical LPSA [3]. (author)

  10. Development of PSA workstation KIRAP

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Tae Un; Han, Sang Hoon; Kim, Kil You; Yang, Jun Eon; Jeong, Won Dae; Chang, Seung Cheol; Sung, Tae Yong; Kang, Dae Il; Park, Jin Hee; Lee, Yoon Hwan; Hwang, Mi Jeong

    1997-01-01

    Advanced Research Group of Korea Atomic Energy Research Institute has been developing the Probabilistic Safety Assessment(PSA) workstation KIRAP from 1992. This report describes the recent development activities of PSA workstation KIRAP. The first is to develop and improve the methodologies for PSA quantification, that are the incorporation of fault tree modularization technique, the improvement of cut set generation method, the development of rule-based recovery, the development of methodology to solve a fault tree which has the logical loops and to handle a fault tree which has several initiators. These methodologies are incorporated in the PSA quantification software KIRAP-CUT. The second is to convert PSA modeling softwares for Windows, which have been used on the DOS environment since 1987. The developed softwares are the fault tree editor KWTREE, the event tree editor CONPAS, and Data manager KWDBMAN for event data and common cause failure (CCF) data. With the development of PSA workstation, it makes PSA modeling and PSA quantification and automation easier and faster. (author). 8 refs.

  11. Development of PSA workstation KIRAP

    International Nuclear Information System (INIS)

    Kim, Tae Un; Han, Sang Hoon; Kim, Kil You; Yang, Jun Eon; Jeong, Won Dae; Chang, Seung Cheol; Sung, Tae Yong; Kang, Dae Il; Park, Jin Hee; Lee, Yoon Hwan; Hwang, Mi Jeong.

    1997-01-01

    Advanced Research Group of Korea Atomic Energy Research Institute has been developing the Probabilistic Safety Assessment(PSA) workstation KIRAP from 1992. This report describes the recent development activities of PSA workstation KIRAP. The first is to develop and improve the methodologies for PSA quantification, that are the incorporation of fault tree modularization technique, the improvement of cut set generation method, the development of rule-based recovery, the development of methodology to solve a fault tree which has the logical loops and to handle a fault tree which has several initiators. These methodologies are incorporated in the PSA quantification software KIRAP-CUT. The second is to convert PSA modeling softwares for Windows, which have been used on the DOS environment since 1987. The developed softwares are the fault tree editor KWTREE, the event tree editor CONPAS, and Data manager KWDBMAN for event data and common cause failure (CCF) data. With the development of PSA workstation, it makes PSA modeling and PSA quantification and automation easier and faster. (author). 8 refs

  12. PSA Velocity Does Not Improve Prostate Cancer Detection

    Science.gov (United States)

    A rapid increase in prostate-specific antigen (PSA) levels is not grounds for automatically recommending a prostate biopsy, according to a study published online February 24, 2011, in the Journal of the National Cancer Institute.

  13. Applications of probabilistic safety assessment (PSA) for nuclear power plants

    International Nuclear Information System (INIS)

    2001-02-01

    This report, which compiles information on a comprehensive set of PSA applications in the areas of NPP design, operation, and accident mitigation and management, is the culmination of an IAEA project on PSA Applications and Tools to Improve NPP Safety. In this regard, the Technical Committee Meeting (TCM) held in Madrid in February 1998 allowed participants to review and provide very valuable comments for this report. Several important facts related to PSA and its applications were highlighted during this TCM: living PSAs are the basis for the risk informed approach to decision making; development and use of safety/risk monitors as tools for configuration management is spreading fast; the different uses of PSA to support NPP testing and maintenance planning and optimization are amongst the most widespread PSA applications; plant specific PSAs are being used to support the safety upgrading programmes of plants built to earlier standards; not all countries have a regulatory framework for the use of the probabilistic approach in decision making. Some countries are still far from 'risk-informed' regulation, and this means that there is still considerable work ahead, both for regulators and utilities, to clarify approaches, to establish a framework and to reach a common understanding in relation to the use of PSA in decision making. This report is based on the premise that the use of PSA can provide useful information for the decision maker. This report is intended to provide an overview of current PSA applications. Section 2 addresses the PSA application process, outlines the general requirements for PSA tools and provides a discussion on PSA aspects such as PSA level, scope and level of detail, which have to be considered when planning/performing PSA applications. Section 3 discusses the technical aspects of individual applications and is divided into three parts. Section 3.1 is dedicated to the design related PSA applications. The second part of Section 3 considers

  14. Ascertaining the international state of the art of PSA methodology

    International Nuclear Information System (INIS)

    Linden, J. von

    1998-01-01

    Plant-specific PSAs, to be performed within the framework of the Periodic Safety Review of German Nuclear Power Plants require further development of the methodology. For that purpose foreign PSA-guidelines and PSA-reviewes as well as relevant literature are examined and appropriate insights are adopted within task A.2 of project SR 2096. The main goal of these activities is to achieve a comparison of the state of the art of PSA-methodologies applied abroad and in Germany. The German state of the art refers to the extent as is documented in the German PSA Guide (Leitfaden Probabilistische Sicherheitsanalyse /PSUe97/) which has to be used for the Periodic Safety Review of German Nuclear Power Plants. The structure for the evaluation is based on the working steps of a PSA. In total, according to the objectives of the Periodic Safety Review the German approach for plant-specific PSAs based on the German PSA Guide is conform to the state of the art abroad. Identified deviations in some details are evaluated reflecting the view of GRS. Particular aspects resulting from the evaluation should be considered for further development of the German PSA Guide. (orig.) [de

  15. PSA time to nadir as a prognostic factor of first-line docetaxel treatment in castration-resistant prostate cancer: evidence from patients in Northwestern China.

    Science.gov (United States)

    Wu, Kai-Jie; Pei, Xin-Qi; Tian, Ge; Wu, Da-Peng; Fan, Jin-Hai; Jiang, Yu-Mei; He, Da-Lin

    2018-01-01

    Docetaxel-based chemotherapy remains the first-line treatment for patients with metastatic castration-resistant prostate cancer (mCRPC) in China; however, the prognostic factors associated with effects in these patients are still controversial. In this study, we retrospectively reviewed the data from 71 eligible Chinese patients who received docetaxel chemotherapy from 2009 to 2016 in our hospital and experienced a reduction of prostate-specific antigen (PSA) level ≥50% during the treatment and investigated the potential role of time to nadir (TTN) of PSA. TTN was defined as the time from start of chemotherapy to the nadir of PSA level during the treatment. Multivariable Cox regression models and Kaplan-Meier analysis were used to predict overall survival (OS). In these patients, the median of TTN was 17 weeks. Patients with TTN ≥17 weeks had a longer response time to chemotherapy compared to TTN PSA progression in patients with TTN ≥17 weeks was 11.44 weeks compared to 5.63 weeks when TTN was PSA level at the diagnosis of cancer (HR: 4.337, 95% CI: 1.616-11.645, P = 0.004), duration of initial androgen deprivation therapy (HR: 2.982, 95% CI: 1.104-8.045, P = 0.031), neutrophil-to-lymphocyte ratio (HR: 3.963, 95% CI: 1.380-11.384, P = 0.011), and total PSA response (Class 1 [PSA remains an important prognostic marker in predicting therapeutic outcome in Chinese population who receive chemotherapy for mCRPC and have >50% PSA remission.

  16. TCTE Level 3 Total Solar Irradiance Daily Means V002

    Data.gov (United States)

    National Aeronautics and Space Administration — The Total Solar Irradiance (TSI) Calibration Transfer Experiment (TCTE) data set TCTE3TSID contains daily averaged total solar irradiance (a.k.a solar constant) data...

  17. [Prostate specific antigen--PSA and histopathological findings of endometrium in women with fibrocystic breast disease].

    Science.gov (United States)

    Radowicki, Stanisław; Kunicki, Michał

    2010-02-01

    The aim of the study was to evaluate the relationship between serum free and total PSA and histopathological findings in women with fibrocystic mastopathy. 176 women with fibrocystic breast disease, aged 18 to 45 years.--Group I: comprised 114 patients with cysts 10 mm in diameter. The control group consisted of 46 healthy women aged 18 - 45 years who had no breast pathology Total PSA (PSA-T) and free PSA (PSA-Free) were measured by an ultra-sensitive fluoroimmunometric DELFIA assay (Prostatus PSA Free/Total Wallac, Turku, Finland). The detection limit for PSA was 0.01 ng/ml. Endometrial samples have been obtained with Pipelle probe between 22 and 24 days of the menstrual cycle. In the control group secretory endometrium was more frequently detected than in the mastopathy group (chi2 = 11,15, p = 0.01). Proliferatory (chi2 = 8.27, p = 0.004) and presecretory endometrium (chi2 = 4.61, p = 0.03) were more frequently detected in the mastopathy group than in controls. We did not find statistically significant relationship between the mean PSA concentrations between the groups in relation to histopathological findings. No relationships between free and total PSA measured in the follicular phase of the menstrual cycle and endometrial findings were detected in our study. Further research is required to evaluate the relationship between PSA and endometrial findings.

  18. Summary report for the second TUV-workshop proceedings on living PSA application

    International Nuclear Information System (INIS)

    1991-01-01

    This workshop on living PSA Application was organized to support the OECD/NEA CSNI-Principal Working Group No.5 on Risk Assessment for an international exchange of experience on living PSA application. The first session was devoted to Living PSA Applications and the second session to Tools for Living PSA. Living PSA Applications: Reasons for performing PSA (regulatory requirement, targets; corporate requirement, targets; safety related activity prioritization; other); Logistic of Living PSA Management (Corporate management involvement, Decision making levels and guidance, Plant level involvement, Required personnel commitment, Frequency and extent of re-quantification of PSA, Types of safety/risk parameters to be monitored, Quality assurance on maintaining Living PSA); Examples of Application (Experiences of application, State of Living PSA/e.g. all accident sequences involved, Details of component level involvement). Tools for Living PSA: Data Collection Systems and Codes (Source and type of data collected, Probabilistic parameter quantification, Interface to basic event data, Data code systems). An executive summary of the workshop is given

  19. Development of PSA audit guideline and regulatory PSA model for SMART

    International Nuclear Information System (INIS)

    Cho, Namchul; Lee, Chang-Ju; Kim, I.S.

    2012-01-01

    SMART is under development for dual purposes of power generation and seawater desalination in Korea. It is an integral reactor type with a thermal power output of 330 MW and employs advanced design features such as a passive system for the removal of residual heat and also the setting of all the components of the primary system inside the reactor pressure vessel. It is essential to develop new probabilistic safety assessment (PSA) validation guidance for SMART. For the purpose of regulatory verification to the risk level of SMART, the insights and key issues on the PSA are identified with referring some worldwide safety guides as well as its design characteristics. Regulatory PSA model under the development for the design confirmation and its preliminary result are also described. (authors)

  20. External Events PSA for the Paks NPP

    International Nuclear Information System (INIS)

    Bareith, Attila; Karsa, Zoltan; Siklossy, Tamas; Vida, Zoltan

    2014-01-01

    Initially, probabilistic safety assessment of external events was limited to the analysis of earthquakes for the Paks Nuclear Power Plant in Hungary. The level 1 seismic PSA was completed in 2002 showing a significant contribution of seismic failures to core damage risk. Although other external events of natural origin had previously been screened out from detailed plant PSA mostly on the basis of event frequencies, a review of recent experience on extreme weather phenomena made during the periodic safety review of the plant led to the initiation of PSA for external events other than earthquakes in 2009. In the meantime, the accident of the Fukushima Dai-ichi Nuclear Power Plant confirmed further the importance of such an analysis. The external event PSA for the Paks plant followed the commonly known steps: selection and screening of external hazards, hazard assessment for screened-in external events, analysis of plant response and fragility, PSA model development, and risk quantification and interpretation of results. As a result of event selection and screening the following weather related external hazards were subject to detailed analysis: extreme wind, extreme rainfall (precipitation), extreme snow, extremely high and extremely low temperatures, lightning, frost and ice formation. The analysis proved to be a significant challenge due to scarcity of data, lack of knowledge, as well as limitations of existing PSA methodologies. This paper presents an overview of the external events PSA performed for the Paks NPP. Important methodological aspects are summarised. Key analysis findings and unresolved issues that need further elaboration are highlighted. Development of external events PSA for the Paks NPP was completed by the end of 2012. The analysis followed the commonly known steps: selection and screening of external hazards, hazard assessment for screened-in external events, analysis of plant response and fragility, PSA model development, and risk

  1. Prediction of PSA bounce after permanent prostate brachytherapy for localized prostate cancer

    International Nuclear Information System (INIS)

    Kanai, Kunimitsu; Nakashima, Jun; Sugawara, Akitomo

    2009-01-01

    We aimed to calculate the frequency and features of the development of a prostate-specific antigen (PSA) bounce after prostate brachytherapy alone, to correlate the bounce with clinical and dosimetric factors and to identify factors that predict PSA bounce. PSA bounce was evaluated in 86 patients with T1-T2 prostate cancer who underwent radioactive seed implantation using iodine-125 (I-125) without hormonal therapy or external-beam radiation therapy (EBRT) from September 2004 to December 2007. A PSA bounce was defined as a rise of at least 0.4 ng/ml greater than a previous PSA level with a subsequent decline equal to, or less than, the initial nadir. Calculated by the Kaplan-Meier method, the incidence of PSA bounce at a 2-year follow-up was 26%. Median time to the PSA bounce was 15 months. Univariate analysis demonstrated that age, dose received by 90% of the prostate gland (D90), volume of gland receiving 100% of the prescribed dose (V100), and V150 were significantly associated with the PSA bounce, while pretreatment PSA level, Gleason score, pretreatment prostate volume, clinical T stage, and V200 were not. In multivariate analysis, age 67 years or less and D90 more than 180 Gy were identified as independent factors for predicting the PSA bounce (P<0.05). PSA bounce is not a rare phenomenon after prostate brachytherapy. It is more common in younger patients and patients receiving higher doses of radiation. (author)

  2. The value of 18F-choline PET/CT in patients with elevated PSA-level and negative prostate needle biopsy for localisation of prostate cancer

    International Nuclear Information System (INIS)

    Igerc, I.; Kohlfuerst, S.; Gallowitsch, H.J.; Matschnig, S.; Kresnik, E.; Gomez-Segovia, I.; Lind, P.

    2008-01-01

    Patients with persistent elevated PSA and repeated negative prostate biopsy, that means having the prostate biopsied at multiple times, were investigated with 18F-choline PET/CT to delineate prostate cancer and guide renewed prostate biopsy. Twenty patients with elevated PSA and negative prostate biopsies underwent 18F-choline PET/CT. We performed an early examination of the pelvic region 3-5 min after application. After 30 minutes a whole body PET/CT examination was performed. Image analysis was performed visually and by semi-quantitative analysis calculating the maximum standardised uptake value (SUVmax). 18F-choline uptake was defined as focal, multifocal or inhomogeneous. After the 18F-choline PET/CT, all patients underwent a repeated prostate biopsy, and in the cases where a focal or multifocal uptake was found, the biopsy was guided by the result of the examination. Qualitative image analysis revealed focal 18F-choline uptake in 13 out of 20 patients. In five patients, prostate cancer was revealed by repeated aspiration biopsy. None of the patients with a multifocal or inhomogeneous 18F-choline uptake had a malignant neoplasm in the prostate. Semiquantitative analysis performed with SUVmax was not helpful in the discrimination of malignancy but showed high values also in benign prostate diseases, as well as in normal prostate tissue. The dual-phase protocol delivered no clear benefit in discriminating malignancy from benign alterations. The use of 18F-choline cannot be generally recommended for localising prostate cancer; however, in highly selected patients, we found useful additional information. In 25% of patients, 18F-choline PET/CT allowed the identification of neoplastic prostatic zones. (orig.)

  3. Nomogram incorporating PSA level to predict cancer-specific survival for men with clinically localized prostate cancer managed without curative intent

    Science.gov (United States)

    Kattan, Michael W.; Cuzick, Jack; Fisher, Gabrielle; Berney, Daniel M.; Oliver, Tim; Foster, Christopher S.; Møller, Henrik; Reuter, Victor; Fearn, Paul; Eastham, James; Scardino, Peter T.

    2012-01-01

    Introduction The prognosis of men with clinically localized prostate cancer is highly variable, and it is difficult to counsel a man who may be considering avoiding, or delaying, aggressive therapy. After collecting data on a large cohort of men who received no initial active prostate cancer therapy, we sought to develop, and to internally validate, a nomogram for prediction of disease-specific survival. Methods Working with 6 cancer registries within England and numerous hospitals in the region, we constructed a population-based cohort of men diagnosed with prostate cancer between 1990 and 1996. All men had baseline serum prostate specific antigen (PSA) measurements, centralized pathologic grading, and centralized review of clinical stage assignment. Based upon the clinical and pathological data from 1,911 men, we developed and validated a statistical model that served as the basis for the nomogram. The discrimination and calibration of the nomogram were assessed with use of one third of the men, who were omitted from modeling and used as a test sample. Results The median age of the included men was 70.4 years. The 25th and 75th percentiles of PSA were 7.3 and 32.6 ng/ml respectively, and the median was 15.4 ng/ml. Forty-two percent of the men had high grade disease. The nomogram predicted well with a concordance index of 0.73 and had good calibration. Conclusions We have developed an accurate tool for predicting the probability that a man with clinically localized prostate cancer will survive his disease for 120 months if the cancer is not treated with curative intent immediately. The tool should be helpful for patient counseling and clinical trial design. PMID:18000803

  4. The correlation of PSA nadir and biochemical freedom from cancer after external beam treatment: effects of stage, grade and pretreatment PSA groupings

    International Nuclear Information System (INIS)

    Pinover, W.H.; Hanlon, A.L.; Lee, W.R.; Hanks, G.E.

    1996-01-01

    Purpose: This study demonstrates the correlation of various post-irradiation PSA nadirs with long term biochemical freedom from disease (bNED) survival in patients treated mainly with conformal external beam radiation therapy. It also shows the effects of various groupings of pretreatment (prerx) PSA level, stage, and Gleason score on the rate of achieving a favorable PSA nadir. Materials and Methods: Three hundred forty patients with known pretreatment PSA, >2 years followup treated with radiation alone (278 conformal, 62 conventional) are reported. The median followup is 41 months (range 24 to 96 mos.). Patient grouping by pretreatment PSA levels are <10 ng/ml (143 patients), 10-19.9 ng/ml (108 patients), ≥20 ng/ml (89 patients); by palpation stage are T1C,2AB (240 patients) and T2C,3,4 (100 patients); and by differentiation are Gleason 2-4 (108 patients), Gleason 5-7 (221 patients), Gleason 8-10 (11 patients). The PSA nadir response is given for all patients, and for each of the above prerx groupings. The 5 year actuarial bNED survival is determined for all patients by PSA nadir. Biochemical failure is a PSA ≥1.5 ng/ml and rising on two consecutive measures. Multivariate analysis (MVA) is performed to determine factors predictive of favorable PSA nadir response and predictive of bNED survival. Results: The PSA nadir responses and 5 year bNED survival rates are shown in the table for all patients according to PSA nadir. 66% of patients achieved a favorable nadir (<1.0 ng/ml) which was associated with a 75%-87% 5 year bNED rate, while 34% achieved an unfavorable nadir associated with an 18-32% bNED survival rate at 5 years. The figure illustrates the dramatic separation in outcome associated with the nadir response. The table also illustrates the fraction of patients that achieve various nadir levels subdivided by prerx PSA level, palpation stage and Gleason score. A favorable PSA nadir is obtained in 90%, 63%, and 31% of patients with a prerx PSA <10, 10

  5. Determining if pretreatment PSA doubling time predicts PSA trajectories after radiation therapy for localized prostate cancer

    International Nuclear Information System (INIS)

    Soto, Daniel E.; Andridge, Rebecca R.; Pan, Charlie C.; Williams, Scott G.; Taylor, Jeremy M.G.; Sandler, Howard M.

    2009-01-01

    Introduction: To determine if pretreatment PSA doubling time (PSA-DT) can predict post-radiation therapy (RT) PSA trajectories for localized prostate cancer. Materials and methods: Three hundred and seventy-five prostate cancer patients treated with external beam RT without androgen deprivation therapy (ADT) were identified with an adequate number of PSA values. We utilized a linear mixed model (LMM) analysis to model longitudinal PSA data sets after definitive treatment. Post-treatment PSA trajectories were allowed to depend on the pre-RT PSA-DT, pre-RT PSA (iPSA), Gleason score (GS), and T-stage. Results: Pre-RT PSA-DT had a borderline impact on predicting the rate of PSA rise after nadir (p = 0.08). For a typical low risk patient (T1, GS ≤ 6, iPSA 10), the predicted PSA-DT post-nadir was 21% shorter for pre-RT PSA-DT 24 month (19 month vs. 24 month). Additional significant predictors of post-RT PSA rate of rise included GS (p < 0.0001), iPSA (p < 0.0001), and T-stage (p = 0.02). Conclusions: We observed a trend between rapidly rising pre-RT PSA and the post-RT post-nadir PSA rise. This effect appeared to be independent of iPSA, GS, or T-stage. The results presented suggest that pretreatment PSA-DT may help predict post-RT PSA trajectories

  6. False high level in total bilirubin estimation in nonicteric serum

    African Journals Online (AJOL)

    estimation of total bilirubin by DiaSys and Randox reagents along with simultaneous re-estimation by Roche reagents in ... been used mainly due to slightly lower cost in ... MATERIALS AND METHODS ... air-conditioned laboratory overnight. ..... Elevated IgG causing spurious elevation in serum total bilirubin assay. Asia.

  7. Generation of risk importance information from severe accident PSA model

    International Nuclear Information System (INIS)

    Seo, Mi Ro; Kim, Hyeong Taek; Moon, Chan Kook

    2012-01-01

    One of the important objects conducting Probabilistic Safety Assessment (PSA) is the relative evaluation of importance of the component or function that is greatly affected to the plant safety. This evaluation is performed by the importance assessment methods such as Risk Reduction Worth, Risk Achievement Worth, and Fuss el Vessley method from the aspect of core damage frequency (CDF). In the Level 1 PSA model, the importance of each component can be evaluated since the CDF is calculated by the combination of the branch probability of event tree and the component failure probability in the fault tree. But, the Level 2 PSA model in order to assess the containment integrity cannot evaluate the risk importance by the above methods because the model is consisted of 3 parts, plant damage status, containment event tree, and source term category. So, in the field that the Level 2 PSA risk importance information should be reflected, such as maintenance rule program, risk importance has been determined by the subjective judgment of the model developer. This study was performed in order to generate the risk importance information more objectively and systematically in the Level 2 PSA model, focused on the containment event tree in the domain PHWR Level 2 PSA model

  8. Prioritization of design changes based on PSA

    International Nuclear Information System (INIS)

    Krajnc, B.; Mavko, B.

    1996-01-01

    Effective use of Probabilistic Safety Analyses (PSA) in the day to day plant operation is subject of intensive discussions among plant operators and regulators. There are several possible applications in which the PSA can be used, among those also to use the PSA approach for the quantification of influence of different proposed design changes to nuclear safety - influence on public safety - health. NPP Krsko is one of those plants that successfully completed its PSA project, with Level 1 and Level 2 analyses and effective know-how transfer. It also faces a number of regulatory and internally generated requirements for different design changes, mainly due to the fact that the plant is committed to continuous augmentation of nuclear safety. It is considered that the available tools and knowledge should be used and therefore applicable methodology should be developed for effective prioritization of proposed design changes by performing cost-benefit analyses for all major modifications - focusing on their influence on nuclear safety. Based on the above a new method for prioritization of design changes is proposed. The method uses Level 1 results (in the sense of plant damage states and their frequencies) directly as an input for further processing - first decision step to decide whether the proposed modification has or has no influence on nuclear safety. In Level 2 analyses the combination of probabilistic and deterministic approach was adopted. In fact the results of the deterministic analyses of severe accidents are treated in probabilistic manner due to large uncertainty of results. Finally to be able to perform plant specific cost benefit analyses so called partial Level 3 was defined. The proposed methods was preliminary tested and it gave favorable results. (author)

  9. The value of multimodality imaging in the investigation of a PSA recurrence after radical prostatectomy in the Irish hospital setting.

    Science.gov (United States)

    McLoughlin, L C; Inder, S; Moran, D; O'Rourke, C; Manecksha, R P; Lynch, T H

    2018-02-01

    The diagnostic evaluation of a PSA recurrence after RP in the Irish hospital setting involves multimodality imaging with MRI, CT, and bone scanning, despite the low diagnostic yield from imaging at low PSA levels. We aim to investigate the value of multimodality imaging in PC patients after RP with a PSA recurrence. Forty-eight patients with a PSA recurrence after RP who underwent multimodality imaging were evaluated. Demographic data, postoperative PSA levels, and imaging studies performed at those levels were evaluated. Eight (21%) MRIs, 6 (33%) CTs, and 4 (9%) bone scans had PCa-specific findings. Three (12%) patients had a positive MRI with a PSA PSA ≥1.1 ng/ml (p = 0.05). Zero patient had a positive CT TAP at a PSA level PSA levels PSA levels PSA levels ≥1.1 ng/ml. MRI alone is of investigative value at PSA <1.0 ng/ml. The indication for CT, MRI, or isotope bone scanning should be carefully correlated with the clinical question and how it will affect further management.

  10. Comparison and lessons learned from plant specific PSA of German NPP

    International Nuclear Information System (INIS)

    Balfanz, Hans-Peter; Berg, H.P.

    2000-01-01

    PSA are launched in frame of Periodic Safety Reviews (PSR) in Germany. The aims are to identify overall safety level and relative weak points. Some backfitting measures have been realized for older plants to remove relative weak points and to bring these plants to the state of the art. In this field PSA is well accepted today and is seen as a valuable tool supplementing the deterministic analysis. Main application of PSA within PSR is planned to become mandatory as part of the revision of the German Atomic Energy Act. According to the German PSA Guideline plant specific PSA level 1+ were performed for all 19 In comparison with international practice German PSA are very detailed. Otherwise they do not handle all external events, non-power states and accident management measures as discussed before. The New PSA guideline will cover these aspects and therefore analysts have to take them into account in further PSA. Moreover gathering of plant specific data is needed. The development in this field is driven by the utilities (for instance in frame of their so-called ZEDB project). Public discussion about quantitative risk of industrial hazards is quite limited in Germany and PSA results have only few impacts to this respect. Independent from this PSA for NPP is understood as a diverse tool in supporting the deterministic licensing and supervision process. Risk based decision making as well as informed regulation are just only of the beginning. State of PSA of NPP in Germany, comparison of PSA result of different NPP, German PSA guideline and state of discussion of further development and recommendation of further development of PSA of NPP are discussed in this paper in more detail. (S.Y.)

  11. Comparison and lessons learned from plant specific PSA of German NPP

    Energy Technology Data Exchange (ETDEWEB)

    Balfanz, Hans-Peter [TUEV Nord, Hamburg (Germany); Berg, H.P.

    2000-07-01

    PSA are launched in frame of Periodic Safety Reviews (PSR) in Germany. The aims are to identify overall safety level and relative weak points. Some backfitting measures have been realized for older plants to remove relative weak points and to bring these plants to the state of the art. In this field PSA is well accepted today and is seen as a valuable tool supplementing the deterministic analysis. Main application of PSA within PSR is planned to become mandatory as part of the revision of the German Atomic Energy Act. According to the German PSA Guideline plant specific PSA level 1+ were performed for all 19 In comparison with international practice German PSA are very detailed. Otherwise they do not handle all external events, non-power states and accident management measures as discussed before. The New PSA guideline will cover these aspects and therefore analysts have to take them into account in further PSA. Moreover gathering of plant specific data is needed. The development in this field is driven by the utilities (for instance in frame of their so-called ZEDB project). Public discussion about quantitative risk of industrial hazards is quite limited in Germany and PSA results have only few impacts to this respect. Independent from this PSA for NPP is understood as a diverse tool in supporting the deterministic licensing and supervision process. Risk based decision making as well as informed regulation are just only of the beginning. State of PSA of NPP in Germany, comparison of PSA result of different NPP, German PSA guideline and state of discussion of further development and recommendation of further development of PSA of NPP are discussed in this paper in more detail. (S.Y.)

  12. Stage T1-2 prostate cancer with pretreatment PSA 10 ng/ml or less: radiotherapy or surgery?

    International Nuclear Information System (INIS)

    Keyser, Douglas; Kupelian, Patrick; Zippe, Craig; Klein, Eric

    1996-01-01

    Purpose: Presently, patients with pretreatment PSA levels ≤10 ng/ml constitute the majority of cases presenting for definitive treatment. Our aim was to determine whether the type of treatment (radiotherapy versus surgery) affected biochemical failure rates in this group of patients. This study is based on 389 patients treated at a single institution. Material and Methods: The charts of all patients treated with either radiotherapy or prostatectomy alone between 1987 and 1993 were reviewed (n=811). Patients with clinical stage T1 or T2 disease, and a pretreatment PSA level (iPSA) of 10.0 or less were analyzed (n=389). Two hundred forty nine (64%) received radical prostatectomy and 140 (36%) received radiotherapy (median dose 66.6 Gy). Pretreatment patient characteristics including clinical stage, biopsy Gleason score (GS) and iPSA level were not significantly different between the radiation and surgery groups (Table 1). The patients treated with radiation were significantly older (median age 70 years vs. 64 years, p<0.05). A total of 37% of the prostatectomy patients had a positive margin. The median follow-up time was 33 months; 1458 follow-up PSA levels were available for analysis. Biochemical failure was defined as a rise in PSA level of 1.0 ng/ml above the nadir PSA level in radiotherapy cases, or any value above 0.2 ng/ml in the prostatectomy cases. Results: The overall 5 year actuarial biochemical relapse free survival (bRFS) rate was 70%. The 5-year bRFS rates for prostatectomy and radiotherapy were identical (70%) (Fig.1). The significant factors affecting bRFS rates were iPSA level (≤4 vs. 4-10 ng/ml) and Gleason score (≤6 vs. ≥7) (Table 2). The 5-year bRFS rates of patients with iPSA ≤4 vs. iPSA 4-10 ng/ml were 92% vs. 61% respectively, p<0.01. The 5-year clinical relapse free survival was 93%. All clinical failures were preceded by biochemical failure. Patients with positive surgical margins did significantly worse than those with negative

  13. Evaluation of PSA-age volume score in predicting prostate cancer in Chinese populationArticle Subject.

    Science.gov (United States)

    Wu, Yi-Shuo; Wu, Xiao-Bo; Zhang, Ning; Jiang, Guang-Liang; Yu, Yang; Tong, Shi-Jun; Jiang, Hao-Wen; Mao, Shan-Hua; Na, Rong; Ding, Qiang

    2018-02-06

    This study was performed to evaluate prostate-specific antigen-age volume (PSA-AV) scores in predicting prostate cancer (PCa) in a Chinese biopsy population. A total of 2355 men who underwent initial prostate biopsy from January 2006 to November 2015 in Huashan Hospital were recruited in the current study. The PSA-AV scores were calculated and assessed together with PSA and PSA density (PSAD) retrospectively. Among 2133 patients included in the analysis, 947 (44.4%) were diagnosed with PCa. The mean age, PSA, and positive rates of digital rectal examination result and transrectal ultrasound result were statistically higher in men diagnosed with PCa (all P PSA-AV were 0.864 and 0.851, respectively, in predicting PCa in the entire population, both performed better than PSA (AUC = 0.805; P PSA-AV was more obvious in subgroup with PSA ranging from 2.0 ng ml-1 to 20.0 ng ml-1. A PSA-AV score of 400 had a sensitivity and specificity of 93.7% and 40.0%, respectively. In conclusion, the PSA-AV score performed equally with PSAD and was better than PSA in predicting PCa. This indicated that PSA-AV score could be a useful tool for predicting PCa in Chinese population.

  14. Blackpool: More evidence on PSA

    International Nuclear Information System (INIS)

    Cullingford, M.

    1985-01-01

    PSA is spreading widely throughout the world, with 30 IAEA Member States having active programmes in this area. The main reason for its popularity is that it offers insights critical in the safety decision-making process available from no other method. It allows power plant designers, regulators, and operators to discriminate between issues important to safety and those which are trivial. Although it is beneficial to perform a PSA to utilize the potential products available from such a study, it is especially important to realize that the PSA process itself is a valuable experience. The main points such as potential users of PSA, safety evaluations, treatment of uncertainties as well as future trends are briefly discussed in this paper

  15. Development of a PSA information database system

    International Nuclear Information System (INIS)

    Kim, Seung Hwan

    2005-01-01

    The need to develop the PSA information database for performing a PSA has been growing rapidly. For example, performing a PSA requires a lot of data to analyze, to evaluate the risk, to trace the process of results and to verify the results. PSA information database is a system that stores all PSA related information into the database and file system with cross links to jump to the physical documents whenever they are needed. Korea Atomic Energy Research Institute is developing a PSA information database system, AIMS (Advanced Information Management System for PSA). The objective is to integrate and computerize all the distributed information of a PSA into a system and to enhance the accessibility to PSA information for all PSA related activities. This paper describes how we implemented such a database centered application in the view of two areas, database design and data (document) service

  16. Human behaviour in PSA

    International Nuclear Information System (INIS)

    Schott, H.

    1999-01-01

    Based on the current international state of the art of methodology for evaluation of human errors for PSA, many research projects have been initiated by the competent departments of the BMU and the BfS (Federal Min. of the Environment and Reactor Safety, Federal Radiation Protection Office). Three major areas of the research activities are discussed: Database: - Specific investigations into the applicability of generic data (THERP) to other than the original cases, possibly elaboration of approaches for application-specific modification, further evaluation of operating results; - general enhancement of insight into human performance and errors, e.g. with respect to causes of error and application areas (influence of organisation, cognitive performance); interviews with experts as a supplementary approach for data verification and database enhancement. Sensitivity analysis: - Identification of information describing human errors essentially contributing to frequency of occurrence of incidents and system non-availability; - establishment of relevance rating system, methodology for uncertainty analysis. Further development of methodology: - Modelling of repair activities and knowledge-based behaviour. (orig./CB) [de

  17. Serum total proteins and creatinine levels in experimental gambian ...

    African Journals Online (AJOL)

    Attempt was therefore made to evaluate the effect of two strains of Trypanosoma brucei gambiense on total proteins and other serum biochemical parameters using vervet monkeys as a model. The outcome of both strains in vervet monkeys was traumatic as the monkeys died from infection 12 – 15 weeks post infection while ...

  18. Serum total protein, albumin and globulin levels in Trypanosoma ...

    African Journals Online (AJOL)

    The effect of orally administered Scoparia dulcis on Trypanosoma brucei-induced changes in serum total protein, albumin and globulin were investigated in rabbits over a period of twenty eight days. Results obtained show that infection resulted in hyperproteinaemia, hyperglobulinaemia and hypoalbuminaemia. However ...

  19. Analysis of urinary PSA glycosylation is not indicative of high-risk prostate cancer.

    Science.gov (United States)

    Barrabés, Sílvia; Llop, Esther; Ferrer-Batallé, Montserrat; Ramírez, Manel; Aleixandre, Rosa N; Perry, Antoinette S; de Llorens, Rafael; Peracaula, Rosa

    2017-07-01

    The levels of core fucosylation and α2,3-linked sialic acid in serum Prostate Specific Antigen (PSA), using the lectins Pholiota squarrosa lectin (PhoSL) and Sambucus nigra agglutinin (SNA), can discriminate between Benign Prostatic Hyperplasia (BPH) and indolent prostate cancer (PCa) from aggressive PCa. In the present work we evaluated whether these glycosylation determinants could also be altered in urinary PSA obtained after digital rectal examination (DRE) and could also be useful for diagnosis determinations. For this purpose, α2,6-sialic acid and α1,6-fucose levels of urinary PSA from 53 patients, 18 biopsy-negative and 35 PCa patients of different aggressiveness degree, were analyzed by sandwich ELLA (Enzyme Linked Lectin Assay) using PhoSL and SNA. Changes in the levels of specific glycosylation determinants, that in serum PSA samples were indicative of PCa aggressiveness, were not found in PSA from DRE urine samples. Although urine is a simpler matrix for analyzing PSA glycosylation compared to serum, an immunopurification step was necessary to specifically detect the glycans on the PSA molecule. Those specific glycosylation determinants on urinary PSA were however not useful to improve PCa diagnosis. This could be probably due to the low proportion of PSA from the tumor in urine samples, which precludes the identification of aberrantly glycosylated PSA. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Association of serum prostate-specific antigen levels with the results of the prostate needle biopsy.

    Science.gov (United States)

    Janbaziroudsari, Hamid; Mirzaei, Arezoo; Maleki, Nasrollah

    2016-09-01

    To investigate the relationship of serum prostate-specific antigen (PSA) levels with outcomes of prostate needle biopsy in men 50 or more years old. We measured serum PSA levels in 1472 healthy men 50 or more years old. Men who had serum PSA values 4.0ng/mL or higher underwent digital rectal examination. If there were either an elevated PSA level (≥4ng/mL) or abnormal digital rectal examination, a transrectal ultrasound-guided prostate biopsy was performed. The mean serum total PSA level was 13.73±11.44ng/mL, and the mean serum free PSA level was 4.99±0.97ng/mL. Of the 260 men who had serum total PSA levels of≥4ng/mL, 139 underwent biopsy. Of these 139 men, 45 (32.4%) had prostate cancer. Benign prostatic hyperplasia with or without prostatitis was diagnosed in 94 patients (67.6%). There was no significant correlation between age and histologic results of prostate needle biopsy (P-value=0.469). The serum free PSA showed no significant correlation with histologic results of prostate needle biopsy, whereas the serum total PSA level had a significant correlation in patients with adenocarcinoma compared with other diagnosis. The overall frequency of detection of prostate adenocarcinoma was 32.4%. This study revealed that no level of PSA was associated with a 100% positive predictive value and negative biopsy can occur virtually at any PSA level. There is a need to create awareness among the general population and health professionals for an early diagnosis of this common form of cancer. Copyright © 2016 Société Française du Cancer. Published by Elsevier Masson SAS. All rights reserved.

  1. An Automated Micro-Total Immunoassay System for Measuring Cancer-Associated α2,3-linked Sialyl N-Glycan-Carrying Prostate-Specific Antigen May Improve the Accuracy of Prostate Cancer Diagnosis

    Directory of Open Access Journals (Sweden)

    Tomokazu Ishikawa

    2017-02-01

    Full Text Available The low specificity of the prostate-specific antigen (PSA for early detection of prostate cancer (PCa is a major issue worldwide. The aim of this study to examine whether the serum PCa-associated α2,3-linked sialyl N-glycan-carrying PSA (S2,3PSA ratio measured by automated micro-total immunoassay systems (μTAS system can be applied as a diagnostic marker of PCa. The μTAS system can utilize affinity-based separation involving noncovalent interaction between the immunocomplex of S2,3PSA and Maackia amurensis lectin to simultaneously determine concentrations of free PSA and S2,3PSA. To validate quantitative performance, both recombinant S2,3PSA and benign-associated α2,6-linked sialyl N-glycan-carrying PSA (S2,6PSA purified from culture supernatant of PSA cDNA transiently-transfected Chinese hamster ovary (CHO-K1 cells were used as standard protein. Between 2007 and 2016, fifty patients with biopsy-proven PCa were pair-matched for age and PSA levels, with the same number of benign prostatic hyperplasia (BPH patients used to validate the diagnostic performance of serum S2,3PSA ratio. A recombinant S2,3PSA- and S2,6PSA-spiked sample was clearly discriminated by μTAS system. Limit of detection of S2,3PSA was 0.05 ng/mL and coefficient variation was less than 3.1%. The area under the curve (AUC for detection of PCa for the S2,3PSA ratio (%S2,3PSA with cutoff value 43.85% (AUC; 0.8340 was much superior to total PSA (AUC; 0.5062 using validation sample set. Although the present results are preliminary, the newly developed μTAS platform for measuring %S2,3PSA can achieve the required assay performance specifications for use in the practical and clinical setting and may improve the accuracy of PCa diagnosis. Additional validation studies are warranted.

  2. Determination of total hydrocarbons levels in some marine ...

    African Journals Online (AJOL)

    Pachyelina aurita), mussels (Mylitus edulis) and mangrove Oysters (Cassostrea gasar) from polluted and unpolluted (i.e. control) sampling stations in parts of the Niger Delta area has been assessed. Statistical results revealed that the THC levels ...

  3. Development and verification of a leningrad NPP unit 1 living PSA model in the INL SAPHIRE code format for prompt operational safety level monitoring

    International Nuclear Information System (INIS)

    Bronislav, Vinnikov

    2007-01-01

    The first part of the paper presents results of the work, that was carried out in complete conformity with the Technical Assignment, which was developed by the Leningrad Nuclear Power Plant. The initial scientific and technical information, contained into the In-Depth Safety Assessment Reports, was given to the author of the work. This information included graphical Fault Trees of Safety Systems and Auxiliary Technical Systems, Event Trees for the necessary number of Initial Events, and also information about failure probabilities of basic components of the nuclear unit. On the basis of this information and fueling it to the Usa Idaho National Laboratory (INL) SAPHIRE code, we have developed an electronic version of the Data Base for failure probabilities of the components of technical systems. Then, we have developed both the electronic versions of the necessary Fault Trees, and an electronic versions of the necessary Event Trees. And at last, we have carried out the linkage of the Event Trees. This work has resulted in the Living PSA (LPSA - Living Probabilistic Safety Assessment) Model of the Leningrad NPP Unit 1. The LPSA-model is completely adapted to be consistent with the USA INL SAPHIRE Risk Monitor. The second part of the paper results in analysis of fire consequences in various places of Leningrad NPP Unit 1. The computations were carried out with the help of the LPSA-model, developed in SAPHIRE code format. On the basis of the computations the order of priority of implementation of fire prevention measures was established. (author)

  4. One Approach to the Fire PSA Uncertainty Analysis

    International Nuclear Information System (INIS)

    Simic, Z.; Mikulicic, V.; Vukovic, I.

    2002-01-01

    Experienced practical events and findings from the number of fire probabilistic safety assessment (PSA) studies show that fire has high relative importance for nuclear power plant safety. Fire PSA is a very challenging phenomenon and a number of issues are still in the area of research and development. This has a major impact on the conservatism of fire PSA findings. One way to reduce the level of conservatism is to conduct uncertainty analysis. At the top-level, uncertainty of the fire PSA can be separated in to three segments. The first segment is related to fire initiating events frequencies. The second uncertainty segment is connected to the uncertainty of fire damage. Finally, there is uncertainty related to the PSA model, which propagates this fire-initiated damage to the core damage or other analyzed risk. This paper discusses all three segments of uncertainty. Some recent experience with fire PSA study uncertainty analysis, usage of fire analysis code COMPBRN IIIe, and uncertainty evaluation importance to the final result is presented.(author)

  5. Survey of Dynamic PSA Methodologies

    International Nuclear Information System (INIS)

    Lee, Hansul; Kim, Hyeonmin; Heo, Gyunyoung; Kim, Taewan

    2015-01-01

    Event Tree(ET)/Fault Tree(FT) are significant methodology in Probabilistic Safety Assessment(PSA) for Nuclear Power Plants(NPPs). ET/FT methodology has the advantage for users to be able to easily learn and model. It enables better communication between engineers engaged in the same field. However, conventional methodologies are difficult to cope with the dynamic behavior (e.g. operation mode changes or sequence-dependent failure) and integrated situation of mechanical failure and human errors. Meanwhile, new possibilities are coming for the improved PSA by virtue of the dramatic development on digital hardware, software, information technology, and data analysis.. More specifically, the computing environment has been greatly improved with being compared to the past, so we are able to conduct risk analysis with the large amount of data actually available. One method which can take the technological advantages aforementioned should be the dynamic PSA such that conventional ET/FT can have time- and condition-dependent behaviors in accident scenarios. In this paper, we investigated the various enabling techniques for the dynamic PSA. Even though its history and academic achievement was great, it seems less interesting from industrial and regulatory viewpoint. Authors expect this can contribute to better understanding of dynamic PSA in terms of algorithm, practice, and applicability. In paper, the overview for the dynamic PSA was conducted. Most of methodologies share similar concepts. Among them, DDET seems a backbone for most of methodologies since it can be applied to large problems. The common characteristics sharing the concept of DDET are as follows: • Both deterministic and stochastic approaches • Improves the identification of PSA success criteria • Helps to limit detrimental effects of sequence binning (normally adopted in PSA) • Helps to avoid defining non-optimal success criteria that may distort the risk • Framework for comprehensively considering

  6. Survey of Dynamic PSA Methodologies

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Hansul; Kim, Hyeonmin; Heo, Gyunyoung [Kyung Hee University, Yongin (Korea, Republic of); Kim, Taewan [KEPCO International Nuclear Graduate School, Ulsan (Korea, Republic of)

    2015-05-15

    Event Tree(ET)/Fault Tree(FT) are significant methodology in Probabilistic Safety Assessment(PSA) for Nuclear Power Plants(NPPs). ET/FT methodology has the advantage for users to be able to easily learn and model. It enables better communication between engineers engaged in the same field. However, conventional methodologies are difficult to cope with the dynamic behavior (e.g. operation mode changes or sequence-dependent failure) and integrated situation of mechanical failure and human errors. Meanwhile, new possibilities are coming for the improved PSA by virtue of the dramatic development on digital hardware, software, information technology, and data analysis.. More specifically, the computing environment has been greatly improved with being compared to the past, so we are able to conduct risk analysis with the large amount of data actually available. One method which can take the technological advantages aforementioned should be the dynamic PSA such that conventional ET/FT can have time- and condition-dependent behaviors in accident scenarios. In this paper, we investigated the various enabling techniques for the dynamic PSA. Even though its history and academic achievement was great, it seems less interesting from industrial and regulatory viewpoint. Authors expect this can contribute to better understanding of dynamic PSA in terms of algorithm, practice, and applicability. In paper, the overview for the dynamic PSA was conducted. Most of methodologies share similar concepts. Among them, DDET seems a backbone for most of methodologies since it can be applied to large problems. The common characteristics sharing the concept of DDET are as follows: • Both deterministic and stochastic approaches • Improves the identification of PSA success criteria • Helps to limit detrimental effects of sequence binning (normally adopted in PSA) • Helps to avoid defining non-optimal success criteria that may distort the risk • Framework for comprehensively considering

  7. [Use of prostatic specific antigen in primary care (PSA)].

    Science.gov (United States)

    Panach-Navarrete, J; Gironés-Montagud, A; Sánchez-Cano, E; Doménech-Pérez, C; Martínez-Jabaloyas, J M

    2017-04-01

    In the literature it is shown that the use of PSA is occasionally wrong, by requesting this marker in very young or very old men, and repeated measurements in short periods of time. The main objective of this study was to describe the use of PSA in daily practice by primary care physicians in our area, dealing with aspects such as the importance of patient age, the value in the screening for prostate cancer, or the subjective beliefs about its usefulness. A secondary objective was the comparison of use, and beliefs among doctors who claim to know PSA well, and those who do not. A descriptive and comparative study was conducted using questionnaires that were handed to primary care doctors in all health centres in our area. A descriptive analysis was performed and response rates among doctors who thought they had enough information about PSA, and those who did not, were compared using the Chi-squared test. A total of 103 questionnaires were received from the physicians, with 83.5% claiming to have sufficient knowledge about the PSA. The professionals in this latter group request PSA at an earlier age (P=.029), with a higher frequency (P=.011) and have more doubts about its usefulness (P=.009) than those with less knowledge. Almost half (49.5%) said they request less than 50 determinations per year, and 33% between 50 and 100. More than half (53.4%) of doctors would not request the first PSA on a patient until their 50s, and up to 49% request it up to 80 years. The true value of PSA has been established many times by 64.1% of requesters, and 29.1% believe it is unhelpful in the diagnosis of cancer. In our study, 64% of primary care physicians have considered the true value of the PSA several times, and 29% believe it to be of little use in the diagnosis of prostate cancer. In addition, some data suggest it has limited use due to the fact that 50% made less than 50 PSA requests per years, and 28% of the professionals would never request it on a male without urinary

  8. Sublethal Effects of Diesel on Total Protein Levels and Cholesterol ...

    African Journals Online (AJOL)

    Michael Horsfall

    were handpicked at the Eagle Cement area of the New Calabar River and subjected to different levels ... groups when compared to the control in both the muscle and the viscera of the periwinkle. ... In Nigeria, oil industry operations are both offshore and onshore. ... This acts as a means of assessing the hazard or potential ...

  9. NRC regulatory uses of PSA

    International Nuclear Information System (INIS)

    Murley, T.E.

    1991-01-01

    The publication in 1975 of WASH-1400, with its new probabilistic safety assessment (PSA) methodology, had the effect of presenting a pair of eyeglasses to a man with poor eyesight. Suddenly, it gave us a view of nuclear safety with a new clarity, and it allowed us to sort out the important safety issues from the unimportant. In the intervening years, PSA insights have permeated the fabric of nearly all our safety judgments. This acceptance can be seen from the following list of broad areas where the Nuclear Regulatory Commission (NRC) staff uses PSA insights and methodology: evaluating the safety significance of operating events and recommending safety improvements where warranted; requesting licensees to systematically look for design vulnerabilities in each operating reactor; evaluating the safety significance of design weaknesses or non-compliances when judging the time frame for necessary improvements; conducting sensitivity analyses to judge where safety improvements are most effective; assessing the relative safety benefits of design features for future reactors. In judging where PSA methodology can be improved to give better safety insights, it is believed that the following areas need more attention: better modeling of cognitive errors; more comprehensive modeling of accident sequences initiated from conditions other than full power; more comprehensive modeling of inter-system loss of coolant accident (ISLOCA) sequences. Although PSA is widely used in the staff's regulatory activities, the NRC deliberately chooses not to include probabilistic prescriptions in regulations or guidance documents. The staff finds the bottom line risk estimates to be one of the least reliable products of a PSA. The reason for this view is that PSA cannot adequately address cognitive errors nor assess the effects of a pervasive poor safety attitude

  10. PSA kinetics following primary focal cryotherapy (hemiablation) in organ-confined prostate cancer patients.

    Science.gov (United States)

    Kongnyuy, Michael; Islam, Shahidul; Mbah, Alfred K; Halpern, Daniel M; Werneburg, Glenn T; Kosinski, Kaitlin E; Chen, Connie; Habibian, David J; Schiff, Jeffrey T; Corcoran, Anthony T; Katz, Aaron E

    2018-02-01

    We aim to evaluate prostate-specific antigen (PSA) trends in post-primary focal cryotherapy (PFC) patients. This was an institutional review board-approved retrospective study of PFC patients from 2010 to 2015. Patients with at least one post-PFC PSA were included in the study. Biochemical recurrence (BCR) was determined using the Phoenix criteria. PSA bounce was also assessed. We analyzed rates of change of PSA over time of post-PFC between BCR and no BCR groups. PSA-derived variables were analyzed as potential predictors of BCR. A total of 104 PFC patients were included in our analysis. Median (range) age and follow-up time were 66 (48-82) years and 19 (6.3-38.6) months, respectively. Four (3.8%) patients experienced PSA bounce. The median percent drop in first post-PFC PSA of 80.0% was not associated with BCR (p = 0.256) and may indicate elimination of the index lesion. The rate of increase of PSA in BCR patients was significantly higher compared to patients who did not recur (median PSA velocity (PSAV): 0.15 vs 0.04 ng/ml/month, p = 0.001). Similar to PSAV (HR 9.570, 95% CI 3.725-24.592, p PSA nadir ≥ 2 ng/ml [HR (hazard ratio) 1.251, 95% CI 1.100-1.422, p = 0.001] was independently associated with BCR. A significant drop in post-PFC PSA may indicate elimination of the index lesion. Patients who are likely to recur biochemically have a significantly higher PSAV compared to those who do not recur. Nadir PSA of less than 2 ng/ml may be considered the new normal PSA in focal cryotherapy (hemiablation) follow-up.

  11. Comparison of serum leptin, glucose, total cholesterol and total protein levels in fertile and repeat breeder cows

    Directory of Open Access Journals (Sweden)

    Saime Guzel

    2014-12-01

    Full Text Available In the present study we measured serum glucose, leptin, total cholesterol and total protein concentrations in repeat breeder cows and compared them with fertile cows. For this aim, 20 repeat breeder cows and 20 fertile cows were used as material. Repeat breeder cows were found to have lower levels of leptin and glucose as compared with fertile ones. No significant differences in total cholesterol and total protein levels were observed between the two groups. No significant correlation of leptin with glucose, total cholesterol and total protein was observed in fertile and repeat breeder cows. Low concentrations of glucose and leptin can have some effects on reproductive problems as repeat breeder and help to understand potential mechanisms impairing fertility in repeat breeder cows.

  12. Method comparison for determination of the tumor markers AFP, CEA, PSA and free PSA between Immulite 2000 XPI and Dimension Vista 1500.

    Science.gov (United States)

    Zur, Berndt; Holdenrieder, Stefan; Walgenbach-Brünagel, Gisela; Albers, Eike; Stoffel-Wagner, Birgit

    2012-01-01

    For the Luminescent Oxygen Channeling Immunoassay (LOCI) technology as established for Dimension Vista 1500, assays have been developed for the serum tumor markers AFP, CEA, PSA and free PSA. We performed a method analysis for these parameters using the Immulite 2000 XPI. Determination of within-day and total imprecision of the methods was carried out according to CLSI guidelines with three serum pools. In addition, parallel measurements were performed with both systems in 1,871 routine serum samples and correlations were calculated. Calculated total imprecision of the three serum pools for AFP was 3.8 - 4.3%, for CEA 3.3 - 4.3%, for tPSA 3.6 - 4.0% and for fPSA it was 3.5 - 8.2%. Correlations of these markers across the entire value range were very good with the following correlation coefficients: 0.997 for AFP, 0.996 for CEA, 0.971 for tPSA and 0.988 for fPSA. While values for AFP and tPSA from both methods were comparable (slopes 1.02 and 1.01), lower values were measured for CEA and fPSA with the Dimension Vista (slopes 0.83 and 0.91). For AFP, a sample cluster with considerably higher values than with Dimension Vista was observed in the lower measurement range (CEA, tPSA and fPSA, as developed with the LOCI technology for the Dimension Vista, show good comparability with results obtained from the Immulite 2000 XPI. However, lower measurement ranges for CEA and fPSA as well as individual divergences, especially with AFP, must be taken into consideration in the event of method changeover.

  13. Influence of PSA, PSA velocity and PSA doubling time on contrast-enhanced 18F-choline PET/CT detection rate in patients with rising PSA after radical prostatectomy

    International Nuclear Information System (INIS)

    Schillaci, Orazio; Calabria, Ferdinando; Tavolozza, Mario; Caracciolo, Cristiana Ragano; Orlacchio, Antonio; Danieli, Roberta; Simonetti, Giovanni; Agro, Enrico Finazzi; Miano, Roberto

    2012-01-01

    To evaluate the accuracy of contrast-enhanced 18 F-choline PET/CT in restaging patients with prostate cancer after radical prostatectomy in relation to PSA, PSA velocity (PSAve) and PSA doubling time (PSAdt). PET/CT was performed in 49 patients (age range 58-87 years) with rising PSA (mean 4.13 ng/ml) who were divided in four groups according to PSA level: ≤1 ng/ml, 1 to ≤2 ng/ml, 2 to ≤4 ng/ml, and >4 ng/ml. PSAve and PSAdt were measured. PET and CT scans were interpreted separately and then together. PET/CT diagnosed relapse in 33 of the 49 patients (67%). The detection rates were 20%, 55%, 80% and 87% in the PSA groups ≤1, 1 to ≤2, 2 to ≤4 and >4 ng/ml, respectively. PET/CT was positive in 7 of 18 patients (38.9%) with a PSA ≤2 ng/ml, and in 26 of 31 (83.9%) with a PSA >2 ng/ml. PET/CT was positive in 7 of 25 patients (84%) with PSAdt ≤6 months, and in 12 of 24 patients (50%) with PSAdt >6 months, and was positive in 26 of 30 patients (86%) with a PSAve >2 ng/ml per year, and in 7 of 19 patients (36.8%) with PSAve ≤2 ng/ml per year. PET alone was positive in 31 of 49 patients (63.3%), and of these 31 patients, CT was negative in 14 but diagnosed bone lesions in 2 patients in whom PET alone was negative. CT with the administration of intravenous contrast medium did not provide any further information. Detection rate of 18 F-choline imaging is closely related to PSA and PSA kinetics. In particular, 18 F-choline PET/CT is recommended in patients with PSA >2 ng/ml, PSAdt ≤6 months and PSAve >2 ng/ml per year. CT is useful for detecting bone metastases that are not 18 F-choline-avid. The use of intravenous contrast agent seems unnecessary. (orig.)

  14. Influence of PSA, PSA velocity and PSA doubling time on contrast-enhanced {sup 18}F-choline PET/CT detection rate in patients with rising PSA after radical prostatectomy

    Energy Technology Data Exchange (ETDEWEB)

    Schillaci, Orazio [University ' ' Tor Vergata' ' , Department of Biopathology and Diagnostic Imaging, Interventional, Rome (Italy); IRCCS Neuromed, Department of Nuclear Medicine and Molecular Imaging, Pozzilli (Italy); Calabria, Ferdinando [IRCCS Neuromed, Department of Nuclear Medicine and Molecular Imaging, Pozzilli (Italy); Tavolozza, Mario; Caracciolo, Cristiana Ragano; Orlacchio, Antonio; Danieli, Roberta; Simonetti, Giovanni [University ' ' Tor Vergata' ' , Department of Biopathology and Diagnostic Imaging, Interventional, Rome (Italy); Agro, Enrico Finazzi; Miano, Roberto [University Hospital ' ' Tor Vergata' ' , Department of Urology, Rome (Italy)

    2012-04-15

    To evaluate the accuracy of contrast-enhanced {sup 18}F-choline PET/CT in restaging patients with prostate cancer after radical prostatectomy in relation to PSA, PSA velocity (PSAve) and PSA doubling time (PSAdt). PET/CT was performed in 49 patients (age range 58-87 years) with rising PSA (mean 4.13 ng/ml) who were divided in four groups according to PSA level: {<=}1 ng/ml, 1 to {<=}2 ng/ml, 2 to {<=}4 ng/ml, and >4 ng/ml. PSAve and PSAdt were measured. PET and CT scans were interpreted separately and then together. PET/CT diagnosed relapse in 33 of the 49 patients (67%). The detection rates were 20%, 55%, 80% and 87% in the PSA groups {<=}1, 1 to {<=}2, 2 to {<=}4 and >4 ng/ml, respectively. PET/CT was positive in 7 of 18 patients (38.9%) with a PSA {<=}2 ng/ml, and in 26 of 31 (83.9%) with a PSA >2 ng/ml. PET/CT was positive in 7 of 25 patients (84%) with PSAdt {<=}6 months, and in 12 of 24 patients (50%) with PSAdt >6 months, and was positive in 26 of 30 patients (86%) with a PSAve >2 ng/ml per year, and in 7 of 19 patients (36.8%) with PSAve {<=}2 ng/ml per year. PET alone was positive in 31 of 49 patients (63.3%), and of these 31 patients, CT was negative in 14 but diagnosed bone lesions in 2 patients in whom PET alone was negative. CT with the administration of intravenous contrast medium did not provide any further information. Detection rate of {sup 18}F-choline imaging is closely related to PSA and PSA kinetics. In particular, {sup 18}F-choline PET/CT is recommended in patients with PSA >2 ng/ml, PSAdt {<=}6 months and PSAve >2 ng/ml per year. CT is useful for detecting bone metastases that are not {sup 18}F-choline-avid. The use of intravenous contrast agent seems unnecessary. (orig.)

  15. PSA Model Improvement Using Maintenance Rule Function Mapping

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Mi Ro [KHNP-CRI, Nuclear Safety Laboratory, Daejeon (Korea, Republic of)

    2011-10-15

    The Maintenance Rule (MR) program, in nature, is a performance-based program. Therefore, the risk information derived from the Probabilistic Safety Assessment model is introduced into the MR program during the Safety Significance determination and Performance Criteria selection processes. However, this process also facilitates the determination of the vulnerabilities in currently utilized PSA models and offers means of improving them. To find vulnerabilities in an existing PSA model, an initial review determines whether the safety-related MR functions are included in the PSA model. Because safety-related MR functions are related to accident prevention and mitigation, it is generally necessary for them to be included in the PSA model. In the process of determining the safety significance of each functions, quantitative risk importance levels are determined through a process known as PSA model basic event mapping to MR functions. During this process, it is common for some inadequate and overlooked models to be uncovered. In this paper, the PSA model and the MR program of Wolsong Unit 1 were used as references

  16. Male Accessory Gland Infection: Relevance of Serum Total Testosterone Levels

    Directory of Open Access Journals (Sweden)

    R. A. Condorelli

    2014-01-01

    Full Text Available Aim of the present study was to evaluate the different ultrasound characterization of fertile symptomatic patients with MAGI (male accessory gland infection according to different serum concentrations of total T (TT. We analyzed the ultrasound and hormonal data of 200 patients aged between 24.0 and 67.0 years. Patients were divided into six groups according to the sextile distribution of TT. Patients with serum concentrations of TT 6.6 ng mL−1 showed a frequency of ultrasound criteria suggestive for bilateral form of prostatitis and prostate-vesiculo-epididymitis and significantly lower compared to the other examined groups. At multivariate logistic regression analysis adjusted for age and BMI, TT was an independent predictive factor of prostatovesiculitis (OR = 0.818 [95% CI: 0.675–0.992]; P<0.01 and prostate-vesiculo-epididymitis (OR = 0.714 [95% CI: 0.578–0.880]; P<0.01, which represent the main forms of complicated MAGI. The results of this study suggest that male hypogonadism could be associated with a different ultrasound characterization of these patients.

  17. What do PSA changes after radiotherapy with or without prior androgen deprivation mean?

    International Nuclear Information System (INIS)

    Denham, J.W.; Woodhead, D.; Lamb, D.S.; Duchesne, G.

    2003-01-01

    The TROG 96.01 randomised patients with Stage B2 and C prostate cancer to radiotherapy alone to 66 Gy (RT), 3 months maximal androgen deprivation (MAD) with goserelin and flutamide prior to and during RT, and 6 months MAD prior to and during RT. Minimum follow up time is now 3 years. Prior to preliminary analysis of one of the trial's main endpoints biochemical relapse free survival (bRFS), the prostate-specific antigen (PSA) time course for every patient was evaluated to assess the performance of the ASTRO definition of biochemical failure (BF). Following MAD and RT PSA levels immediately rise in the majority of cases (PSA 'rebound'). In over 50% of cases, PSA levels then plateau at <1 ng/ml for 2 - 3 years prior to clear evidence of failure. Premature diagnosis of BF is possible in some of these cases. Fluctuations in PSA level ('bouncing') are more frequent after MAD and RT. As a result there can be difficulty in interpreting the ASTRO definition of BF in cases where overall PSA trend is upwards shortly after completion of therapy. In patients experiencing BF, the rate of PSA rise often corresponds to the site of failure. PSA doubling times (DT) under 7 months are usually associated with development of bony metastases, while DTs greater than that are usually associated with local failure. Decline in PSA levels following RT alone is frequently not mono-exponential and patients with those patterns experience lower PSA nadir levels and are subject to lower risks of all forms of relapse. These patients also survive longer. In cases where PSA descent patterns are discernable after MAD and RT, opposite trends are seen. Caution is necessary in diagnosing BF after MAD plus RT. Variations in the natural history of prostate cancer are reflected by variations in the rate of PSA changes following therapy. The importance of monitoring this marker and evaluating its time course is emphasised. Prospective studies are needed

  18. An endoglycosidase-assisted LC-MS/MS-based strategy for the analysis of site-specific core-fucosylation of low-concentrated glycoproteins in human serum using prostate-specific antigen (PSA) as example.

    Science.gov (United States)

    Lang, Robert; Leinenbach, Andreas; Karl, Johann; Swiatek-de Lange, Magdalena; Kobold, Uwe; Vogeser, Michael

    2018-05-01

    Recently, site-specific fucosylation of glycoproteins has attracted attention as it can be associated with several types of cancers including prostate cancer. However, individual glycoproteins, which might serve as potential cancer markers, often are very low-concentrated in complex serum matrices and distinct glycan structures are hard to detect by immunoassays. Here, we present a mass spectrometry-based strategy for the simultaneous analysis of core-fucosylated and total prostate-specific antigen (PSA) in human serum in the low ng/ml concentration range. Sample preparation comprised an immunoaffinity capture step to enrich total PSA from human serum using anti-PSA antibody coated magnetic beads followed by consecutive two-step on-bead partial deglycosylation with endoglycosidase F3 and tryptic digestion prior to LC-MS/MS analysis. The method was shown to be linear from 0.5 to 60 ng/ml total PSA concentrations and allows the simultaneous quantification of core-fucosylated PSA down to 1 ng/ml and total PSA lower than 0.5 ng/ml. The imprecision of the method over two days ranged from 9.7-23.2% for core-fucosylated PSA and 10.3-18.3% for total PSA depending on the PSA level. The feasibility of the method in native sera was shown using three human specimens. To our knowledge, this is the first MS-based method for quantification of core-fucosylated PSA in the low ng/ml concentration range in human serum. This method could be used in large patient cohorts as core-fucosylated PSA may be a diagnostic biomarker for the differentiation of prostate cancer and other prostatic diseases, such as benign prostatic hyperplasia (BPH). Furthermore, the described strategy could be used to monitor potential changes in site-specific core-fucosylation of other low-concentrated glycoproteins, which could serve as more specific markers ("marker refinement") in cancer research. Copyright © 2018 Elsevier B.V. All rights reserved.

  19. Image Guided Hypofractionated Radiotherapy by Helical Tomotherapy for Prostate Carcinoma: Toxicity and Impact on Nadir PSA

    Directory of Open Access Journals (Sweden)

    Salvina Barra

    2014-01-01

    Full Text Available Aim. To evaluate the toxicity of a hypofractionated schedule for primary radiotherapy (RT of prostate cancer as well as the value of the nadir PSA (nPSA and time to nadir PSA (tnPSA as surrogate efficacy of treatment. Material and Methods. Eighty patients underwent hypofractionated schedule by Helical Tomotherapy (HT. A dose of 70.2 Gy was administered in 27 daily fractions of 2.6 Gy. Acute and late toxicities were graded on the RTOG/EORTC scales. The nPSA and the tnPSA for patients treated with exclusive RT were compared to an equal cohort of 20 patients treated with conventional fractionation and standard conformal radiotherapy. Results. Most of patients (83% did not develop acute gastrointestinal (GI toxicity and 50% did not present genitourinary (GU toxicity. After a median follow-up of 36 months only grade 1 of GU and GI was reported in 6 and 3 patients as late toxicity. Average tnPSA was 30 months. The median value of nPSA after exclusive RT with HT was 0.28 ng/mL and was significantly lower than the median nPSA (0.67 ng/mL of the conventionally treated cohort (P=0.02. Conclusions. Hypofractionated RT schedule with HT for prostate cancer treatment reports very low toxicity and reaches a low level of nPSA that might correlate with good outcomes.

  20. The value of 18 F FDG-PET/CT for detecting prostate disease in patients with elevated serum PSA level%18F-FDG PET/CT 诊断血清 PSA 升高患者前列腺病变的应用价值

    Institute of Scientific and Technical Information of China (English)

    滕翀; 张军

    2014-01-01

    目的:探讨用18 F-FDG PET/CT检测血清PSA升高患者前列腺癌发生的可能性。方法纳入PSA升高的疑似前列腺癌患者。在病理活检前行18 F-FDG PET/CT检查,18 F-FDG PET/CT 检查包括全身18 F-FDG PET 扫描、全身增强CT扫描和盆腔18 F-FDG PET延迟成像,并将影像结果与病理结果相比较。结果该研究纳入38名血清PSA升高的患者。18 F-FDG PET延迟成像与增强CT的平行试验(方法一)的敏感度,特异度,阳性预测值,阴性预测值,准确度分别是94.74%(18/19)、52.63%(0/19)、66.67%(18/27)、90.91%(10/11)、73.68%(28/38);18 F-FDG PET 延迟成像与增强C T的系列实验(方法二)的敏感度,特异度,阳性预测值,阴性预测值,准确度分别是52.63%(10/19)、84.21%(16/19)、76.92%(10/13)、64.00%(16/25)、68.42%(26/38)。方法一与方法二的的敏感度和特异度存在统计学差异。结论18 F-FDG PET/CT可用于血清PSA升高患者前列腺癌的检出。%Objective The aim of this study is to evaluate the potential of 18 F-FDG PET/CT for detecting prostate cancer in subjects with an elevated serum prostate-specific antigen (PSA) level .Methods Subjects with an increasing PSA level suggestive of prostate cancer were enrolled in this study .18 F-FDG PET/CT was performed prior to prostate biopsy and the findings were compared with the pathological results .18 F-FDG PET/CT was composed of a whole body 18 F-FDG PET scan ,a whole body contrast-enhanced CT scan and a delay pelvis 18 F-FDG PET scan .Results Thirty-eight subjects with an elevated serum PSA level were taken part in this study .We defined parallel test of contrast-enhanced CT scan and delay 18 F-FDG PET scan as TextⅠ ,as well as we defined serial test of contrast-enhanced CT scan and delay 18 F-FDG PET scan as Text Ⅱ .The sensitivity ,specificity ,positive predictive value ,negative predictive

  1. Severe accident analysis of a steam generator tube rupture accident using MAAP-CANDU to support level 2 PSA for the Point Lepreau Generating Station Refurbishment Project

    Energy Technology Data Exchange (ETDEWEB)

    Petoukhov, S.M.; Brown, M.J. [Canadian Nuclear Laboratories, Chalk River, ON (Canada)

    2015-07-01

    A Level 2 Probabilistic Safety Assessment was performed for the Point Lepreau Generating Station. The MAAP-CANDU code was used to simulate the progression of postulated severe core damage accidents and fission product releases. This paper discusses the results for the reference case of the Steam Generator Tube Rupture initiating event. The reference case, dictated by the Level 2 Probabilistic Safety Assessment, was extreme and assumed most safety-related plant systems were not available: all steam generator feedwater; the emergency water supply; the moderator, shield and shutdown cooling systems; and all stages of emergency core cooling. The reference case also did not credit any post Fukushima lessons or any emergency mitigating equipment. The reference simulation predicted severe core damage beginning at 3.7 h, containment failure at 6.4 h, moderator boil off by 8.2 h, and calandria vessel failure at 42 h. A total release of 5.3% of the initial inventory of radioactive isotopes of Cs, Rb and I was predicted by the end of the simulation (139 h). Almost all noble gas fission products were released to the environment, primarily after the containment failure. No hydrogen/carbon monoxide burning was predicted. (author)

  2. PSA bounce phenomenon after transperineal interstitial permanent prostate brachytherapy for localized prostate cancer

    International Nuclear Information System (INIS)

    Morita, Masashi; Lederer, J.L.; Fukagai, Takashi; Yoshida, Hideki; Shimada, Makoto

    2004-01-01

    We described the temporarily increase phenomenon in prostate-specific antigen level (PSA bounce) after transperineal interstitial permanent prostate brachytherapy (TIPPB) for localized prostate cancer. From December 1998 to May 2003, 500 consecutive patients with localized prostate cancer were treated with TIPPB using iodine-125 or palladium-103. We examined 200 patients who have more than 2-year PSA follow-up. Median follow-up length was 1,069 days (range, 712-1,411 days). No patient received neoadjuvant or adjuvant hormone therapy. PSA determinations were performed every 3 months for the first 2 years after procedure, and every 6 months hereafter. PSA bounce was defined as an increase of 0.1 ng/ml or greater above the preceding PSA level after implant followed by a subsequent decrease below that level. The American Society for Therapeutic Radiology and Oncology (ASTRO) consensus panel criteria 1996 were used to define biochemical failure. PSA bounce was observed in 40% (80/200) of the cases receiving TIPPB. The median time to PSA bounce was 13 months from the day of implant. The median magnitude of the PSA bounce was 0.3 ng/ml from the pre-bounce level. Twelve cases demonstrated biochemical failure according to the ASTRO consensus guidelines of three consecutive rises in PSA. Ten of these subsequently showed a drop in PSA, consistent with biologic control of their disease. Two cases remain classified as apparent biochemical failures. A transient rise in the PSA following TIPPB, the so-called ''bounce'' is a common occurrence. The apparent PSA control of ten of twelve cases failing by the ASTRO criteria raises some concern. Further observation will be necessary to determine ways to discriminate these from true disease progression. (author)

  3. Investigation of total α and total β radioactive level of environment mediator in the Dushu lake campus of Suzhou university

    International Nuclear Information System (INIS)

    Jiang Wenhua; Wan Jun; Liu Li; He Chao; Tang Hua; Tu Yu

    2008-01-01

    Objective: To get the message of natural radioactive level in the Dushu lake cam- pus of Suzhou university. Methods: Different types of water, soil and food in this region were collected, and then the level of total α and total β radioactivity of the sample was investigated applying model BH1216 equipment which measuring was used for low background total α and β radioactivity. Results: Total α in city water, surface water and soil were 0.061 Bq/L, 0.104 Bq/L, 1708 Bq/kg respectively, total β were 0.183 Bq/L, 0.319 Bq/L, 780 Bq/kg respectively, total α in chive, potato, water bamboo, pork, fish were 1.83, 2.36, 1.84, 3.40, 3.76 Bq/kg respectively, total α of Fish bone was at infra-monitoring lower limit, total β in them were 70.81, 96.71, 60.63, 86.20, 97.51, 73.94 Bq/kg respectively. Conclusion: The results of the investigation display that the total radioactivity in drinking water and food don't exceed limits, in surface water and soil is at normal natural background. It can be concluded that this region has not been polluted by the artificial radioactivity and the environment of human habitation is healthy and safe. (authors)

  4. The role of PSA in safety management

    International Nuclear Information System (INIS)

    Szikszai, T.

    1997-01-01

    The presentation discusses the following issues: defence in depth principle (the role of the barriers, how does PSA represents the barriers?); the safety management and nuclear power plants; the probabilistic and deterministic approaches; the PSA applications and safety management

  5. Enlarged level-1 PSA in regard to assessment of cross-cutting effects of hazards and consideration of their uncertainties for a KONVOI type PWR reference plant; Erweiterte PSA der Stufe 1 im Hinblick auf die Behandlung uebergreifender Einwirkungen und die Beruecksichtigung ihrer Unsicherheiten am Beispiel einer Anlage vom Typ Konvoi

    Energy Technology Data Exchange (ETDEWEB)

    Haider, C.; Hofer, E.; Kloos, M.; Kuntze, W.; Liemersdorf, H.; Roewekamp, M.; Schwinges, B.; Tuerschmann, M.; Brenig, H.W.; Sommerfeld, H.

    2001-06-01

    In the frame of supporting BMU regarding generic questions concerning probabilistic safety analyses for nuclear power plants as well as regarding evaluation of nuclear specific standards and guidelines the significant contributions to damage states resulting from plant internal and external hazards had to be estimated for a German Konvoi type PWR reference plant. Furthermore, the suitability of the available methods for assessing these hazards should be checked. In the report presented hereafter, only the plant internal hazard Fire out of all the hazards to be considered was probabilistically analysed in detail First of all, screening analyses were carried out for identifying relevant plant areas and to assess their respective efficiency for a proper selection procedure. For a selected, plant area identified to be relevant (area of the cable distributions inside the reactor containment) an indepth analysis was performed. This analysis included all the steps of the probabilistic assessment, starting from the estimation of the fire occurrence frequency, followed by investigations on the fire effects and fire propagation, up to the determination of the fire induced failure probabilities of safety related equipment including the consequences on systems. In addition, the analyses contained particular uncertainty and sensitivity studies, for which aleatoric and epistemic uncertainties were distinguished. As a result of the screening analyses as well as of the in-depth investigations regarding the fire hazard, no significant contributions for the total frequencies for system, core, or plant damage states have been found. In this context, it has to be noticed that the study presented hereafter does not cover a complete fire PSA. With respect to assessing the available methods it has been found that improvements concerning the screening process as well as concerning the probabilistic fire event tree analyses are necessary. With regard to further hazards, a site specific

  6. Seismic PSA of nuclear power plants a case study

    International Nuclear Information System (INIS)

    Hari Prasad, M.; Dubey, P.N.; Reddy, G.R.; Saraf, R.K.; Ghosh, A.K.

    2006-07-01

    Seismic Probabilistic Safety Assessment (Seismic PSA) analysis is an external event PSA analysis. The objective of seismic PSA for the plants is to examine the existence of plant vulnerabilities against postulated earthquakes by numerically assessing the plant safety and to take appropriate measures to enhance the plant safety. Seismic PSA analysis integrates the seismic hazard analysis, seismic response analysis, seismic fragility analysis and system reliability/ accident sequence analysis. In general, the plant consists of normally operating and emergency standby systems and components. The failure during an earthquake (induced directly by excessive inertial stresses or indirectly following the failure of some other item) of an operating component will lead to a change in the state of the plant. In that case, various scenarios can follow depending on the initiating event and the status of other sub-systems. The analysis represents these possible chronological sequences by an event tree. The event trees and the associated fault trees model the sub-systems down to the level of individual components. The procedure has been applied for a typical Indian nuclear power plant. From the internal event PSA level I analysis significant contribution to the Core Damage Frequency (CDF) was found due to the Fire Water System. Hence, this system was selected to establish the procedure of seismic PSA. In this report the different elements that go into seismic PSA analysis have been discussed. Hazard curves have been developed for the site. Fragility curve for the seismically induced failure of Class IV power has been developed. The fragility curve for fire-water piping system has been generated. Event tree for Class IV power supply has been developed and the dominating accident sequences were identified. CDF has been estimated from these dominating accident sequences by convoluting hazard curves of initiating event and fragility curves of the safety systems. (author)

  7. Development of a PSA information management system

    International Nuclear Information System (INIS)

    Ho, Seok; Dong Kyu, Kim; Sun Koo, Kang

    2007-01-01

    In general, Probabilistic Safety Agreement (PSA) is a very complicated work that uses and generates a lot of resources such as reports, procedures, drawings, assumptions, calculation sheets, PSA model, and so on. In many PSAs, however, the data, materials and knowledge considered and generated during performing PSA are scattered in many documents so that overall structure of PSA and information relationship between documents and models cannot easily be understood. To organize and manage all documents related to PSA, to capture knowledge of analysts, and finally to improve the quality of PSA, a PSA information management system (PIMS) was developed. The PIMS can manage all the documents of a PSA in a database and connect the causal relation between one information to another in the scattered documents via link. The PIMS can manage all the assumptions and technical basis used in PSA, and it can keep the record of the design changes the revision of PSA model. It can also control the review results of PSA models. The link of the PIMS can explicitly describe and reveal the expertise of the PSA analysts, and it enables the users to capture the knowledge and to understand the structure and contents of a PSA with ease. We are planning to apply the PIMS to the PSA of Shin Kori Units 1 and 2 as feasibility study and then to all the PSAs of the nuclear power plants in Korea. The PIMS is expected to contribute to enhancing the quality and confidence of PSA and reducing the efforts and costs of maintenance and update of PSA. (authors)

  8. Development of a PSA information management system

    Energy Technology Data Exchange (ETDEWEB)

    Ho, Seok; Dong Kyu, Kim; Sun Koo, Kang [Korea Power Engineering Company, Inc (Korea, Republic of)

    2007-07-01

    In general, Probabilistic Safety Agreement (PSA) is a very complicated work that uses and generates a lot of resources such as reports, procedures, drawings, assumptions, calculation sheets, PSA model, and so on. In many PSAs, however, the data, materials and knowledge considered and generated during performing PSA are scattered in many documents so that overall structure of PSA and information relationship between documents and models cannot easily be understood. To organize and manage all documents related to PSA, to capture knowledge of analysts, and finally to improve the quality of PSA, a PSA information management system (PIMS) was developed. The PIMS can manage all the documents of a PSA in a database and connect the causal relation between one information to another in the scattered documents via link. The PIMS can manage all the assumptions and technical basis used in PSA, and it can keep the record of the design changes the revision of PSA model. It can also control the review results of PSA models. The link of the PIMS can explicitly describe and reveal the expertise of the PSA analysts, and it enables the users to capture the knowledge and to understand the structure and contents of a PSA with ease. We are planning to apply the PIMS to the PSA of Shin Kori Units 1 and 2 as feasibility study and then to all the PSAs of the nuclear power plants in Korea. The PIMS is expected to contribute to enhancing the quality and confidence of PSA and reducing the efforts and costs of maintenance and update of PSA. (authors)

  9. Eプレート'栄研' PSAキットを用いた臨床的検討 : 前立腺癌患者におけるfree PSA, complex PSA, およびfree/total%の臨床有用性

    OpenAIRE

    今井, 強一; 山中, 英壽; 久保田, 裕; 三木, 誠; 伊藤, 貴章; 赤座, 英之; 内田, 克紀; 頴川, 晋; 栗山, 学; 渡邉, 泱; 沖原, 宏治; 古武, 敏彦; 宇佐美, 道之; 荒井, 陽一; 前田, 浩

    1998-01-01

    1)f-PSAとc-PSA測定系とも各抗原を特異的に測定し,t-PSA測定系はf-PSAとc-PSAを1:1の割合で測定していた. 2)f/t%とf/c%は共にPCaにおいてA1やB0のような早い病期からnon PCaと有意差が認められた. 3)t-PSAとc-PSA及びf/t%とf/c%のROC曲線における差は殆ど認められず,c-PSAの診断上の有用性はt-PSAと同等と思われた.f-PSA単独では有用性が認められなかった. 4)t-PSAが4~10ng/mlの検体においてはf/t%とf/c%がPSA-Dと同様に前立腺癌の診断に有効であった. 5)前立腺体積40ml以上でt-PSAが10ng/ml以下では癌でない確率が高い...

  10. The treatment of nonpalpable PSA-detected adenocarcinoma of the prostate with 3-dimensional conformal radiation therapy

    International Nuclear Information System (INIS)

    Horwitz, Eric M.; Hanlon, Alexandra L.; Pinover, Wayne H.; Hanks, Gerald E.

    1998-01-01

    Purpose: We reviewed our institution's experience treating patients with nonpalpable PSA-detected prostate cancer with three-dimensional conformal radiation therapy (3DCRT) to determine prognostic factors that predict for biochemical-free survival (bNED) control and present the bNED control rates. Methods and Materials: Between May 1, 1990 and November 30, 1994, 160 patients with nonpalpable PSA-detected prostate cancer received 3DCRT at Fox Chase Cancer Center (median total dose 73 Gy; range: 67-78 Gy). bNED failure was defined as three consecutive increases in posttreatment PSA after achieving a nadir. bNED failure was recorded as the time midway between the nadir and the first consecutive rising PSA. Five-year actuarial rates of bNED control were calculated for pretreatment PSA (0-9.9 vs. 10-19.9 vs. ≥ 20 ng/ml), Gleason score (2-6 vs. 7-10), treatment field size (prostate vs. small pelvis), age ( 73 Gy) using Kaplan-Meier methods and compared using the Log rank test. The Cox model was used to multivariately establish independent predictors based on significant univariate factors. Median follow-up was 39 months (range: 2-84 months). Results: The 5-year actuarial rate of bNED control was 86% for the entire group of patients. The Cox Proportional Hazards model demonstrated that pretreatment PSA was an independent predictor of bNED control. Treatment field size was marginally predictive. There was no difference in bNED control when patients were stratified by the number of lobes positive for disease. Statistically different rates of bNED control were seen when the patients with nonpalpable disease were univariately compared to T2b and T2c patients. Three patients experienced Grade 3-4 genitourinary (GU) toxicity and 3 patients experienced Grade 3-4 gastrointestinal (GI) toxicity. Conclusions: Patients with nonpalpable PSA-detected prostate cancer can be effectively treated with 3DCRT with minimal morbidity and high rates of bNED control at 5 years. Pretreatment

  11. The inverse relationship between prostate-specific antigen (PSA) and obesity.

    Science.gov (United States)

    Aref, Adel; Vincent, Andrew D; O'Callaghan, Michael; Martin, Sean; Sutherland, Peter; Hoy, Andrew; Butler, Lisa M; Wittert, Gary

    2018-06-25

    Obese men have lower serum prostate-specific antigen (PSA) than comparably aged lean men, but the underlying mechanism remains unclear. The aim of this study was to determine the effect of obesity on PSA and the potential contributing mechanisms. A cohort of 1195 men aged 35 years and over at recruitment, with demographic, anthropometric (body mass index (BMI), waist circumference (WC)) and serum hormone (serum testosterone (T), estradiol (E2)), PSA and hematology assessments obtained over two waves was assessed. Men with a history of prostate cancer or missing PSA were excluded, leaving 970 men for the final analysis. Mixed-effects regressions and mediation analyses adjusting for hormonal and volumetric factors explore the potential mechanisms relating obesity to PSA. After adjusting for age, PSA levels were lower in men with greater WC (p=0.001). In a multivariable model including WC, age, E2/T and PlasV as predictors, no statistically significant associations were observed between with PSA and either WC (p=0.36) or PlasV (p=0.49), while strong associations were observed with both E2/T (pPSA (p=0.31), while when E2/T is a mediator; the ACME explained roughly 0.5 of the effect (pPSA levels in obese men, as compared to normal weight men, can be explained both by hormonal changes (elevated E2/T ratio) and haemodilution. Hormonal factors therefore represent a substantial but underappreciated mediating pathway.

  12. Comparison of SKIFS 2004:1 and Tillsynshandbok PSA against the ASME PRA Standard and European requirements on PSA

    International Nuclear Information System (INIS)

    Hellstroem, Per

    2005-04-01

    Requirements on PSA for risk informed applications are expressed in different international documents. The ASME PRA standard published in spring 2002 is one such document, PSA requirements are also expressed in the European Utility Requirements (EUR) for new reactors. The Swedish PSA requirements are provided in the Swedish regulators (SKI) statutes SKIFS 2004:1. SKI also has a review handbook for PSA activities (SKI report 2003:48). The review handbook is a support during review of the utilities PSA activities and the PSAs themselves. The review handbook expresses SKIs expectations by providing so called important aspects for both the PSA work and the PSAs, A comparison of SKIFS requirements and the important aspects in the Review handbook, on one side, and the requirements on PSA in EUR and ASME on the other side, is presented. The comparison shows a large difference in the level of detail in the different documents, where ASME is most detailed and specific. This is expected since the SKI review handbook not is a 'PSA guide' in the same way as the ASME PRA standard. A direct comparison of the ASME PRA standard requirements with the important aspects in the review handbook cannot answer the question which ASME capacity level that is achieved by a PSA meeting all important aspects. The conclusion is that it is not likely to achieve capacity level 2 and 3, since very few ASME level 3 attributes are explicitly expressed as important aspects, though many are expressed in general terms. The review handbook important aspects that are most similar to the ASME capacity level 1 attributes are initiating events, sequence analysis, and system analysis while less similarity is found for analysis of operator actions data analysis, quantification and containment analysis (level 2). Less similarity is found for capacity level 2 and 3. However, the number of additional ASME attributes on capacity level 2 and 3 are few. There are also important aspects in the review handbook that

  13. Cost implications of PSA screening differ by age.

    Science.gov (United States)

    Rao, Karthik; Liang, Stella; Cardamone, Michael; Joshu, Corinne E; Marmen, Kyle; Bhavsar, Nrupen; Nelson, William G; Ballentine Carter, H; Albert, Michael C; Platz, Elizabeth A; Pollack, Craig E

    2018-05-09

    Multiple guidelines seek to alter rates of prostate-specific antigen (PSA)-based prostate cancer screening. The costs borne by payers associated with PSA-based screening for men of different age groups-including the costs of screening and subsequent diagnosis, treatment, and adverse events-remain uncertain. We sought to develop a model of PSA costs that could be used by payers and health care systems to inform cost considerations under a range of different scenarios. We determined the prevalence of PSA screening among men aged 50 and higher using 2013-2014 data from a large, multispecialty group, obtained reimbursed costs associated with screening, diagnosis, and treatment from a commercial health plan, and identified transition probabilities for biopsy, diagnosis, treatment, and complications from the literature to generate a cost model. We estimated annual total costs for groups of men ages 50-54, 55-69, and 70+ years, and varied annual prostate cancer screening prevalence in each group from 5 to 50% and tested hypothetical examples of different test characteristics (e.g., true/false positive rate). Under the baseline screening patterns, costs of the PSA screening represented 10.1% of the total costs; costs of biopsies and associated complications were 23.3% of total costs; and, although only 0.3% of all screen eligible patients were treated, they accounted for 66.7% of total costs. For each 5-percentage point decrease in PSA screening among men aged 70 and older for a single calendar year, total costs associated with prostate cancer screening decreased by 13.8%. For each 5-percentage point decrease in PSA screening among men 50-54 and 55-69 years old, costs were 2.3% and 7.3% lower respectively. With constrained financial resources and with national pressure to decrease use of clinically unnecessary PSA-based prostate cancer screening, there is an opportunity for cost savings, especially by focusing on the downstream costs disproportionately associated with

  14. Hepatitis Awareness Month PSA (:30)

    Centers for Disease Control (CDC) Podcasts

    2011-05-11

    May is National Hepatitis Awareness Month. This 30 second PSA discusses hepatitis and encourages listners to talk to their health care professional about getting tested.  Created: 5/11/2011 by National Center for HIV/AIDS, Viral Hepatitis, STD, and TB Prevention.   Date Released: 5/11/2011.

  15. World AIDS Day PSA (:30)

    Centers for Disease Control (CDC) Podcasts

    2011-11-16

    December 1 is World AIDS Day. In this PSA, communities are encouraged to get tested for HIV.  Created: 11/16/2011 by National Center for HIV/AIDS, Viral Hepatitis, STD, and TB Prevention (NCHHSTP).   Date Released: 11/16/2011.

  16. Raccoon Roundworm Infection PSA (:60)

    Centers for Disease Control (CDC) Podcasts

    2012-08-27

    This 60 second PSA describes the signs and symptoms of and ways to prevent Baylisascaris infection, a parasitic roundworm infection that is spread through raccoon feces.  Created: 8/27/2012 by Centers for Disease Control and Prevention (CDC).   Date Released: 8/28/2012.

  17. Methods and use of PSA

    International Nuclear Information System (INIS)

    Vaurio, J.

    2005-01-01

    The objective is to introduce possible methods and methodological issues for application of PSA for decision making at nuclear power plants based on risk and cost, to present a number of application examples, and to describe recommendations and regulatory guides for risk-informed applications. (orig.)

  18. State of living PSA and further development

    International Nuclear Information System (INIS)

    1999-01-01

    In October 1985 OECD-Principal Working Group (PWG 5) - Risk Assessment has initiated the Task Force 7 'Use of PSA in Nuclear Power Plant Management' to explore and report on the principles, characteristics, requirements and status of PSA oriented safety management. During this study, it became apparent that the utilisation of PSA techniques in nuclear plant safety management requires the development of supporting programmes to ensure that PSA models are being updated to reflect plant changes, and to direct their use towards the evaluation and determination of plant changes. These requirements also influence the software and hardware characteristics necessary to support the programme. This overall process is known as Living PSA. In this context OECD-PWG 5 has arranged international workshops on Living PSA application to support this development, to facilitate exchange of international experience and to summarise the state-of-the-art of L-PSA methodology. These activities were accompanied by following Task Groups of OECD-PWG 5 and the work results were published in state-of-the-art reports. According to the increasing development of Living PSA in the international field and its capacity to support plant safety management in a broad sense, OECD PWG 5 continues its work in setting up the Task Group 96-1 'State of Living PSA and Further Development' to clarify specific aspects of Living PSA. This report summarises the state of Living PSA in the international field based on the four Living PSA Workshops from 1988 to 1994 (Chapter 2) and the state of Reliability Data Collection based on the results of Task Group 12 'Reliability Data Collection and Analysis to Support PSA' and the two Data-Workshops from 1995 and 1998 (Chapter 3). The specific items of further development of Living PSA application as mentioned above are treated in Chapter 4. Chapter 5 gives a summary of the current state of Living PSA as well as outlook and recommendations of further development

  19. PROSTATE CANCER SCREENING: PSA TEST AWARENESS AMONG ADULT MALES.

    Science.gov (United States)

    Obana, Michael; O'Lawrence, Henry

    2015-01-01

    The overall purpose of this study was to determine whether visits to the doctor in the last 12 months, education level, and annual household income for adult males increased the awareness of prostate-specific antigen (PSA) tests. The effect of these factors for the knowledge of PSA exams was performed using statistical analysis. A retrospective secondary database was utilized for this study using the questionnaire in the California Health Interview Survey from 2009. Based on this survey, annual visits to the doctor, higher educational levels attained, and greater take-home pay were statistically significant and the results of the study were equivalent to those hypothesized. This also reflects the consideration of marketing PSA blood test screenings to those adult males who are poor, uneducated, and do not see the doctor on a consistent basis.

  20. Serum PSA Evaluations during salvage radiotherapy for post-prostatectomy biochemical failures as prognosticators for treatment outcomes

    International Nuclear Information System (INIS)

    Do, Tri; Dave, Giatri; Parker, Robert; Kagan, A. Robert

    2001-01-01

    Introduction: Serum prostate specific antigen (PSA) levels have proved to be sensitive markers for the diagnosis of prostate cancer. In addition, PSA levels are useful for detecting and monitoring prostate cancer progression after radiotherapy. Serum PSA evaluations during radiotherapy, however, have not been well documented. In this study, we investigate the prognostic value of PSA evaluations during salvage radiotherapy for prostatectomy failures. Methods: Forty-one patients with biochemical failures after prostatectomy treated with salvage radiotherapy consented to have their serum PSA levels evaluated at 30 Gy and 45 Gy of irradiation. All 41 patients had negative metastatic workup and pathologically uninvolved pelvic lymph nodes at the time of referral for salvage radiotherapy. Radiation therapy was delivered with 10-25 MV photons, with doses of 59.4-66.6 Gy. No patients received hormonal ablation therapy before irradiation. Results: The mean follow-up for all patients was 30.9 months. At last follow-up, 28/41 patients (68.3%) were free from biochemical failure, with 20 of 41 patients (48.8%) expressing undetectable PSA levels. Serum PSA evaluations at 30 Gy did not significantly predict for either biochemical (p=0.0917) or clinical (p=0.106) disease-free outcome. However, serum PSA evaluations at 45 Gy significantly predicted for both biochemical (p=0.0043) and clinical (p=0.0244) disease-free outcomes, with PSA elevations at 45 Gy significantly associated with poor outcomes. On univariate analysis of prognosticators for biochemical failures, the following were significant: an elevation in serum PSA levels at 45 Gy, detectable serum PSA immediately after prostatectomy, Gleason score 7-10, and serum PSA level >1 ng/ml before salvage radiotherapy. Conclusion: Evaluation of serum PSA level at 45 Gy of salvage radiotherapy for biochemical relapses after prostatectomy may serve as a significant prognosticator for both biochemical and clinical disease-free outcomes

  1. utility of prostate specific antigen (psa) in the indigenous african man

    African Journals Online (AJOL)

    the standard PSA reference levels generated in non-African study subjects. Design: A ... the best use of PSA in the indigenous black African man but also his place in the new ... tendency as well as measures of dispersion. Inferential statistics assumed a 95% confidence interval and .... men: Results from a pilot study.

  2. PSA applications. Good practices and documentation

    International Nuclear Information System (INIS)

    Dewailly, J.; Magne, L.

    1997-10-01

    In this paper, it is shown what the condensed documentation of the main strategic choices and technical assumptions related to a PSA could contain: how to select the internal and external initiating events, how the detail the plant configuration and the general organization of the plant and operating staff, how to highlight the assumptions related to physical models, etc. The proposals in this documentation are based on the R and D D's experience with PSA (construction of PSA models, use of PSA models for operation or maintenance, PSA tools). This document also presents different types of rules or recommendations related to PSA modelling for various applications involved in nuclear power plant operating. Finally, the paper stresses the main difficulties encountered (appropriate use of uncertainties, communication of PSA results to non-specialist users) and it also outlines some prospects for the future. (author)

  3. Methodology for seismic PSA of NPPs

    International Nuclear Information System (INIS)

    Jirsa, P.

    1999-09-01

    A general methodology is outlined for seismic PSA (probabilistic safety assessment). The main objectives of seismic PSA include: description of the course of an event; understanding the most probable failure sequences; gaining insight into the overall probability of reactor core damage; identification of the main seismic risk contributors; identification of the range of peak ground accelerations contributing significantly to the plant risk; and comparison of the seismic risk with risks from other events. The results of seismic PSA are typically compared with those of internal PSA and of PSA of other external events. If the results of internal and external PSA are available, sensitivity studies and cost benefit analyses are performed prior to any decision regarding corrective actions. If the seismic PSA involves analysis of the containment, useful information can be gained regarding potential seismic damage of the containment. (P.A.)

  4. Re-examining Prostate-specific Antigen (PSA) Density: Defining the Optimal PSA Range and Patients for Using PSA Density to Predict Prostate Cancer Using Extended Template Biopsy.

    Science.gov (United States)

    Jue, Joshua S; Barboza, Marcelo Panizzutti; Prakash, Nachiketh S; Venkatramani, Vivek; Sinha, Varsha R; Pavan, Nicola; Nahar, Bruno; Kanabur, Pratik; Ahdoot, Michael; Dong, Yan; Satyanarayana, Ramgopal; Parekh, Dipen J; Punnen, Sanoj

    2017-07-01

    To compare the predictive accuracy of prostate-specific antigen (PSA) density vs PSA across different PSA ranges and by prior biopsy status in a prospective cohort undergoing prostate biopsy. Men from a prospective trial underwent an extended template biopsy to evaluate for prostate cancer at 26 sites throughout the United States. The area under the receiver operating curve assessed the predictive accuracy of PSA density vs PSA across 3 PSA ranges (10 ng/mL). We also investigated the effect of varying the PSA density cutoffs on the detection of cancer and assessed the performance of PSA density vs PSA in men with or without a prior negative biopsy. Among 1290 patients, 585 (45%) and 284 (22%) men had prostate cancer and significant prostate cancer, respectively. PSA density performed better than PSA in detecting any prostate cancer within a PSA of 4-10 ng/mL (area under the receiver operating characteristic curve [AUC]: 0.70 vs 0.53, P PSA >10 mg/mL (AUC: 0.84 vs 0.65, P PSA density was significantly more predictive than PSA in detecting any prostate cancer in men without (AUC: 0.73 vs 0.67, P PSA increases, PSA density becomes a better marker for predicting prostate cancer compared with PSA alone. Additionally, PSA density performed better than PSA in men with a prior negative biopsy. Copyright © 2017 Elsevier Inc. All rights reserved.

  5. Review of updated design of SPWR with PSA methodology

    International Nuclear Information System (INIS)

    Oikawa, Tetsukuni; Muramatsu, Ken

    1995-01-01

    This paper presents the procedures and results of a PSA (Probabilistic Safety Assessment) of the SPWR (System-Integrated PWR), which is being developed at the Japan Atomic Energy Research Institute (JAERI) as a medium sized innovative passive safe reactor, to assist in the design improvement of the SPWR at the basic or conceptual design phase by reviewing the design and identifying the design vulnerability. The first phase PSA, which was carried out in 1991, was a scoping analysis in order to understand overall plant characteristics and to search for general design weakness. After discussing the results of the first phase PSA, the SPWR designer group changed some designs of the SPWR. The second phase PSA of the SPWR was performed for the modified design in order to identify the design vulnerability as well as to grasp its overall safety level. Special items of these PSAs are as follows: (1) systematic identification of initiating events related to newly designed systems by the failure mode effect analysis (FMEA), (2) delineation of accident sequences for the internal initiating events using accident progression flow charts which is cost effective for conceptual design phase, (3) quantification of event trees based on many engineering judgement, and (4) lots of sensitivity analyses to examine applicability of data assignment. Qualitative and quantitative results of PSA provided very useful information for decision makings of design improvement and recommendations for further consideration in the process of detailed design. (author)

  6. The relation of serum PSA and Gleason's grade in patients with prostacic carcinoma

    Directory of Open Access Journals (Sweden)

    Živković Slađana

    2003-01-01

    Full Text Available The prostatic adenocarcinoma is one of the most frequent malignant tumors of men over 50 years of age. It is distinguished by agressive clinical course and heterogeneous multifocal hystomorphologic changes. PSA is the most reliable serum marker in diagnostics and observation of prostatic carcinoma and gleason's system of tumor-diferentiation grading is generally accepted way of determining the hystologic grade. Gleason's system is correlated with serum levels of PSA and with biological behaviour of the tumor. We presented 40 patients with verified ACP in whom the level of serum PSA, gleason's grade and score were compared. Highly significant correlation was found between serum level of PSA and the differentation grade of the tumor - Gleason's grade and score. Combination of PSA parameters and Gleason's score enables correct estimation of tumor's behaviour and correct therapeutic protocole.

  7. Can Serum Albumin Level and Total Lymphocyte Count be Surrogates for Malnutrition to Predict Wound Complications After Total Knee Arthroplasty?

    Science.gov (United States)

    Morey, Vivek M; Song, Young Dong; Whang, Ji Sup; Kang, Yeon Gwi; Kim, Tae Kyun

    2016-06-01

    Although the serum albumin level and total lymphocyte count (TLC) have been reported as valid and reliable markers for defining malnutrition, their cutoff levels and predictive values for wound complications in patients undergoing total knee arthroplasty (TKA) remain questionable. A total of 3169 TKAs performed between April 2003 and December 2013 were retrospectively reviewed. We determined the prevalence of malnutrition on applying different definitions, with various cutoff values of serum albumin and TLC and analyzed the variations in outcome. The differences between groups with and without malnutrition in terms of functional outcome and complications were determined using Student's t test and analysis of variance. Multivariate logistic regression analysis was conducted to identify the independent risk factors. Among all the patients (N = 3169), the serum albumin level and TLC varied widely, with means of 4.1 g/dL and 2189 cells/mm(3), respectively. The prevalence of malnutrition (21%) as per the conventional definition (serum albumin level malnutrition was defined as serum albumin malnutrition for predicting wound complications after TKA. Copyright © 2015 Elsevier Inc. All rights reserved.

  8. Experience in PSA fault tree modularization at the ASCO NPP

    International Nuclear Information System (INIS)

    Nos Llorens, V.; Frances Urmeneta, M.; Fraig Sureda, J.

    1995-01-01

    Probabilistic Safety Analysis (PSA) is a basic tool in decision-making for the optimization of back fittings, procedures and maintenance practices. ASCO NPP PSA was developed with a high level of detail in the models. This required considerable computer resources (long running time) to carry out the quantification. The quantification time had therefore to be flexible to allow continuous evaluation of the impact on the estimation and reduction of risk in the plant, and also to facilitate post-PSA applications. The most suitable way of achieving this flexibility was by compacting and reducing the detailed fault trees of the project by means of a modularization process. The purpose of the paper is to present the practical experience acquired with modularization carried out in the UTE UNITEC-INYPSA-EMPRESARIOS AGRUPADOS framework and the method applied, the support computer programs devised and their degree of effectiveness. (Author)

  9. Too Much Sodium PSA (:60)

    Centers for Disease Control (CDC) Podcasts

    This 60 second PSA is based on the February 2012 CDC Vital Signs report. Ninety percent of Americans age two and older eat too much sodium which can increase your risk for high blood pressure and often leads to heart disease and stroke, two leading causes of death in the US. Learn several small steps you can take to reduce the amount of sodium in your diet.

  10. The clinical value of serum PSA and PAP determinations in prostate cancer patients

    International Nuclear Information System (INIS)

    Zeng Lei; Yu Renbo; Du Guowei; Pang Baozhong

    2001-01-01

    Objective: To investigate the clinical value of serum PSA and PAP determinations in diagnosis of prostate cancer patients. Methods: The serum PSA and PAP levels of 98 prostate cancer patients, 45 prostate benign disease patients and 40 normal subjects were tested by IRMA. Results: The serum PSA and PAP levels of prostate cancer patients were significantly higher than those in prostate benign disease patients and normal controls (P < 0.01). The diagnostic sensitivity and specificity of serum PSA for prostate cancer were 93.9% and 93.3% respectively. The diagnostic sensitivity and specificity of serum PAP for prostate cancer were 71.4% and 91.1% respectively. Conclusion: The determination of serum PSA and PAP was of high clinical value for diagnosis of early prostate cancer. It could be used as an important reference parameter for the clinical staging, follow-up of treatment result and prediction of prognosis

  11. Status of the PSA use in the Czech regulatory process

    International Nuclear Information System (INIS)

    Dusek, J.

    1994-01-01

    A review of previous probabilistic safety assessment (PSA) activities initiated by regulatory body and preparation of the preliminary PSA study and final PSA study (released in January 1994) for the nuclear power plant Dukovany with WWER-440 type 213 reactor is described. A brief information about the NPP Temelin (with WWER-1000) PSA Study, shutdown and PSA risk monitor current activities for the NPP Dukovany, next PSA activities in 1994 and about planned PSA activities in future is attached. (author). 21 refs

  12. Qualification of calculation aids for PSA

    International Nuclear Information System (INIS)

    Goetz, K.; Hennigs, W.; Kirstein, B.M.; Reinhardt, C.

    1998-01-01

    In Germany Probabilistic Safety Analysis (PSA) are part of the evaluation of a nuclear power plants safety. The German PSA guide stipulates that the used software must enable a PSA according to the state of the art. This software must be qualified to assure that its features, mathematic methods and its performance enable a PSA like this. In this research work specifications and requirements are developed, which allow the testing of software. A procedure was developed to qualify PSA software according to the PSA guide and the experiences of users of PSA. Setting up a procedure, a tool for a systematic and uniform examination was crated. Additionally the options, mathematic fundamentals and performance of PSA-programs were analyzed. According to this all programs that were analyzed are capable to sovle their original task, that is the calculation of the safety of high available system based on high available components. Against that the requirements of modern PSA, e.g. to handle less available functions, HRA and fire analyses, based on the use of modern software and the implementation of new developments in the field of PSA are not supported adequately by all programs. (orig.) [de

  13. Use of PSA in a regulatory framework

    International Nuclear Information System (INIS)

    Ross, P.J.

    1994-01-01

    The paper will briefly describe the use of PSA in the licensing process for the Sizewell 'B' PWR Power Station currently under construction in the U.K. There are two distinct phases in the licensing process - (i) A PSA has been performed to support the application to construct Sizewell 'B'. At that stage the PSA was used as a design tool (along with deterministic design requirements) for Sizewell 'B' and as such lead to a number of significant design changes in the early design process. (ii) A PSA is currently being performed to support the application to operate Sizewell 'B'. The PSA is required to support the claim that the design has included all reasonably practical measures to prevent and mitigate accidents. The comprehensive PSA being produced for the second phase of the licensing process will be described. The way the regulators/designer/analysts have interacted over the years has affected the scope, complexity, detail and bias of the comprehensive PSA. The paper will discuss these issues and highlight some of the more significant ones. The benefits and drawbacks of providing a PSA in a regulatory framework will be discussed. One of the conclusions of the paper is that the use of true ''best-estimates'' in the PSA is difficult to achieve in a regulatory framework where persistent bias to the conservative side is apparent in the designers, analysts and regulators judgements. The usefulness of the PSA is therefore, potentially, compromised by giving misleading outputs or diverting resources to unnecessary areas. (author)

  14. Polysialylated-neural cell adhesion molecule (PSA-NCAM in the human trigeminal ganglion and brainstem at prenatal and adult ages

    Directory of Open Access Journals (Sweden)

    Melis Tiziana

    2008-11-01

    Full Text Available Abstract Background The polysialylated neuronal cell adhesion molecule (PSA-NCAM is considered a marker of developing and migrating neurons and of synaptogenesis in the immature vertebrate nervous system. However, it persists in the mature normal brain in some regions which retain a capability for morphofunctional reorganization throughout life. With the aim of providing information relevant to the potential for dynamic changes of specific neuronal populations in man, this study analyses the immunohistochemical occurrence of PSA-NCAM in the human trigeminal ganglion (TG and brainstem neuronal populations at prenatal and adult age. Results Western blot analysis in human and rat hippocampus supports the specificity of the anti-PSA-NCAM antibody and the immunodetectability of the molecule in postmortem tissue. Immunohistochemical staining for PSA-NCAM occurs in TG and several brainstem regions during prenatal life and in adulthood. As a general rule, it appears as a surface staining suggestive of membrane labelling on neuronal perikarya and proximal processes, and as filamentous and dot-like elements in the neuropil. In the TG, PSA-NCAM is localized to neuronal perikarya, nerve fibres, pericellular networks, and satellite and Schwann cells; further, cytoplasmic perikaryal staining and positive pericellular fibre networks are detectable with higher frequency in adult than in newborn tissue. In the adult tissue, positive neurons are mostly small- and medium-sized, and amount to about 6% of the total ganglionic population. In the brainstem, PSA-NCAM is mainly distributed at the level of the medulla oblongata and pons and appears scarce in the mesencephalon. Immunoreactivity also occurs in discretely localized glial structures. At all ages examined, PSA-NCAM occurs in the spinal trigeminal nucleus, solitary nuclear complex, vestibular and cochlear nuclei, reticular formation nuclei, and most of the precerebellar nuclei. In specimens of different age

  15. [Clinical evaluation of TANDEM PSA in Japanese cases and comparison with other methods].

    Science.gov (United States)

    Kuriyama, M; Yamamoto, N; Shinoda, I; Kawada, Y; Akimoto, S; Shimazaki, J

    1995-01-01

    Clinical evaluation of TANDEM PSA which is the most frequently used prostate specific antigen (PSA) assay method in the world and a comparison with other methods were performed in Japanese cases in a cooperative research fashion. The minimum detectable level of the method was found to be 0.50 ng of PSA in one ml of serum and 1.9 ng/ml was regarded as the upper normal value in Japanese males. The distribution of serum PSA showed a significant difference between the benign prostate hypertrophy (BPH) cases and patients with stage C or D prostate cancer. The sero-diagnosis prostate cancer at an early stage with the TANDEM PSA was difficult. The correlation to other methods of PSA detection was very high. Furthermore, the clinical use of the method in following-up the clinical course of prostate cancer patients was very useful. These findings suggested that the PSA detection using TANDEM PSA is applicable even in Japanese cases although the upper cut-off level is decreased.

  16. Development of simple immunoradiometric assay kits for measurement of Prostate Specific Antigen (PSA)

    International Nuclear Information System (INIS)

    Najafi, R.; Zarsav, P.; Pourabdi, M.; Moharamzadeh, M.; Mahdiani, B.

    1999-01-01

    The report summarizes our results obtained in the field of PSA IRMA kits development. In these experiments, we used Avidin-Biotin technology for coating of antibodies on beads/tubes and studied various parameters, such as investigation of different types of tubes, incubation time, volume of samples etc., as well as comparing two types of Mabs of PSA (free and total) for coating on the surface of bead/tube and obtaining optimized requirements to achieve reliable and simplified assays of PSA (free and total) in serum. (author)

  17. Clinical performance of serum prostate-specific antigen isoform [-2]proPSA (p2PSA) and its derivatives, %p2PSA and the prostate health index (PHI), in men with a family history of prostate cancer: results from a multicentre European study, the PROMEtheuS project.

    Science.gov (United States)

    Lazzeri, Massimo; Haese, Alexander; Abrate, Alberto; de la Taille, Alexandre; Redorta, Joan Palou; McNicholas, Thomas; Lughezzani, Giovanni; Lista, Giuliana; Larcher, Alessandro; Bini, Vittorio; Cestari, Andrea; Buffi, Nicolòmaria; Graefen, Markus; Bosset, Olivier; Le Corvoisier, Philippe; Breda, Alberto; de la Torre, Pablo; Fowler, Linda; Roux, Jacques; Guazzoni, Giorgio

    2013-08-01

    To test the sensitivity, specificity and accuracy of serum prostate-specific antigen isoform [-2]proPSA (p2PSA), %p2PSA and the prostate health index (PHI), in men with a family history of prostate cancer (PCa) undergoing prostate biopsy for suspected PCa. To evaluate the potential reduction in unnecessary biopsies and the characteristics of potentially missed cases of PCa that would result from using serum p2PSA, %p2PSA and PHI. The analysis consisted of a nested case-control study from the PRO-PSA Multicentric European Study, the PROMEtheuS project. All patients had a first-degree relative (father, brother, son) with PCa. Multivariable logistic regression models were complemented by predictive accuracy analysis and decision-curve analysis. Of the 1026 patients included in the PROMEtheuS cohort, 158 (15.4%) had a first-degree relative with PCa. p2PSA, %p2PSA and PHI values were significantly higher (P PHI (AUC: 0.733) to be the most accurate predictors of PCa at biopsy, significantly outperforming total PSA ([tPSA] AUC: 0.549), free PSA ([fPSA] AUC: 0.489) and %fPSA (AUC: 0.600) (P ≤ 0.001). For %p2PSA a threshold of 1.66 was found to have the best balance between sensitivity and specificity (70.4 and 70.1%; 95% confidence interval [CI]: 58.4-80.7 and 59.4-79.5 respectively). A PHI threshold of 40 was found to have the best balance between sensitivity and specificity (64.8 and 71.3%, respectively; 95% CI 52.5-75.8 and 60.6-80.5). At 90% sensitivity, the thresholds for %p2PSA and PHI were 1.20 and 25.5, with a specificity of 37.9 and 25.5%, respectively. At a %p2PSA threshold of 1.20, a total of 39 (24.8%) biopsies could have been avoided, but two cancers with a Gleason score (GS) of 7 would have been missed. At a PHI threshold of 25.5 a total of 27 (17.2%) biopsies could have been avoided and two (3.8%) cancers with a GS of 7 would have been missed. In multivariable logistic regression models, %p2PSA and PHI achieved independent predictor status and

  18. Safety and efficacy of procedural sedation and analgesia (PSA ...

    African Journals Online (AJOL)

    Safety and efficacy of procedural sedation and analgesia (PSA) conducted by medical officers in a level 1 hospital in Cape Town. ... Respiratory complications were treated with simple airway manoeuvres; no patient required intubation or experienced respiratory problems after waking up. There was no significant difference ...

  19. Antigenic determinants of prostate-specific antigen (PSA) and development of assays specific for different forms of PSA.

    OpenAIRE

    Nilsson, O.; Peter, A.; Andersson, I.; Nilsson, K.; Grundstr?m, B.; Karlsson, B.

    1997-01-01

    Monoclonal antibodies were raised against prostate-specific antigen (PSA) by immunization with purified free PSA, i.e. not in complex with any protease inhibitor (F-PSA) and PSA in complex with alpha1-anti-chymotrypsin (PSA-ACT). Epitope mapping of PSA using the established monoclonal antibody revealed a complex pattern of independent and partly overlapping antigenic domains in the PSA molecule. Four independent antigenic domains and at least three partly overlapping domains were exposed both...

  20. PSA modeling of long-term accident sequences

    International Nuclear Information System (INIS)

    Georgescu, Gabriel; Corenwinder, Francois; Lanore, Jeanne-Marie

    2014-01-01

    In the context of the extension of PSA scope to include external hazards, in France, both operator (EDF) and IRSN work for the improvement of methods to better take into account in the PSA the accident sequences induced by initiators which affect a whole site containing several nuclear units (reactors, fuel pools,...). These methodological improvements represent an essential prerequisite for the development of external hazards PSA. However, it has to be noted that in French PSA, even before Fukushima, long term accident sequences were taken into account: many insight were therefore used, as complementary information, to enhance the safety level of the plants. IRSN proposed an external events PSA development program. One of the first steps of the program is the development of methods to model in the PSA the long term accident sequences, based on the experience gained. At short term IRSN intends to enhance the modeling of the 'long term' accident sequences induced by the loss of the heat sink or/and the loss of external power supply. The experience gained by IRSN and EDF from the development of several probabilistic studies treating long term accident sequences shows that the simple extension of the mission time of the mitigation systems from 24 hours to longer times is not sufficient to realistically quantify the risk and to obtain a correct ranking of the risk contributions and that treatment of recoveries is also necessary. IRSN intends to develop a generic study which can be used as a general methodology for the assessment of the long term accident sequences, mainly generated by external hazards and their combinations. This first attempt to develop this generic study allowed identifying some aspects, which may be hazard (or combinations of hazards) or related to initial boundary conditions, which should be taken into account for further developments. (authors)

  1. Best-practices guidelines for L2PSA development and applications. Volume 1 - General

    International Nuclear Information System (INIS)

    Raimond, E.; Pichereau, F.; Durin, T.; Rahni, N.; Loeffler, H.; Roesch, O.; Lajtha, G.; Santamaria, C.S.; Dienstbier, J.; Rydl, A.; Holmberg, J.E.; Lindholm, I.; Maennistoe, I.; Pauli, E.M.; Dirksen, G.; Grindon, L.; Peers, K.; Bassi, C.; Hulqvist, G.; Parozzi, F.; Polidoro, F.; Cazzoli, E.; Vitazkova, J.; Burgazzi, L.; Brinkman, H.; Seidel, A.; Schubert, B.; Wohlstein, R.; Guentay, S.; Oury, L.; Ngatchou, C.; Siltanen, S.; Niemela, I.; Routamo, T.; Vincon, L.; Helstroem, P.

    2010-01-01

    The objective of this coordinated action was to develop best practice guidelines for the performance and application of Level 2 PSA with a view to achieve harmonisation at EU level and to allow a meaningful and practical uncertainty evaluation in a Level 2 PSA. Specific relationships with communities in charge of nuclear reactor safety (utilities, safety authorities, vendors, and research or services companies) have been established in order to define the current needs in terms of guidelines for Level 2 PSA development and application. An international workshop was organised in Hamburg, with the support of VATTENFALL, in November 2008. The Level 2 PSA experts from ASAMPSA2 project partners have proposed some guidelines for the development and application of L2PSA based on their experience, open literature, and on information available from international cooperation (EC Severe Accident network of Excellence - SARNET, IAEA standards, OECD-NEA publications and workshop). There are a large number of technical issues addressed in the guideline which are not all covered with the same level of detail in the first version of the guideline. This version was submitted for external review in November 2010 by severe accident and PSA experts (especially from SARNET and OECD-NEA members). The feedback of the external review will be dis cussed during an international open works hop planned for March 2011 and all outcomes will be taken into consideration in the final version of this guideline (June 2011). The guideline includes 3 volumes: - Volume 1 - General considerations on L2PSA. - Volume 2 - Technical recommendations for Gen II and III reactors. - Volume 3 - Specific considerations for future reactors (Gen IV). The recommendations formulated in the guideline should not be considered as 'mandatory' but should help Level 2 PSA developers to achieve high quality studies with limited time and resources. It may also help Level 2 PSA reviewers by positioning one specific study in

  2. PSA, subjective probability and decision making

    International Nuclear Information System (INIS)

    Clarotti, C.A.

    1989-01-01

    PSA is the natural way to making decisions in face of uncertainty relative to potentially dangerous plants; subjective probability, subjective utility and Bayes statistics are the ideal tools for carrying out a PSA. This paper reports that in order to support this statement the various stages of the PSA procedure are examined in detail and step by step the superiority of Bayes techniques with respect to sampling theory machinery is proven

  3. Policy and System Approach (PSA: A primer

    Directory of Open Access Journals (Sweden)

    Chandrakant Lahariya

    2017-01-01

    Full Text Available A number of public health challenges have emerged at global and national level in the last two decades. The response to these challenges has rarely been swift and often “knee-jerk.” The national and state level program officials responsible for the activities often apportion the blame on weak health systems or fragmented health service delivery mechanisms, amongst other. In India, the viral illnesses (including those due to dengue and chikungunya are becoming the increasing realities. The Public health response of early identification, disease surveillance, reporting and the preventive and curative measures, remains suboptimal. The health challenges which require multidimensional interventions are usuallyattempted to be resolved through piece meal solutions. This article proposes “policy and system approach (PSA,” combining concepts of “Health in all policies” for intersectoral coordination and “health system approach” for intra-sectoral tackling of the emerging and existing health challenges.

  4. Status and use of PSA in Sweden

    International Nuclear Information System (INIS)

    Knochenhauer, M.

    1996-05-01

    The performance and use of PSA:s in Sweden goes back about two decades. During all of this time, the field of PSA has been developing intensively, both internationally and within Sweden. The latest years have been characterised by an increased use of PSA models and results, and by major extensions of existing PSA models. The aim of this document is to describe PSA in Sweden with respect to development, scope and maturity, as well as to the contents of the analyses and the use of results. PSA activities will be described from the point of view of both the authorities and the utilities. The report gives an overview of the development within the area of PSA in Sweden both its history and current trends. The aim has been to include a reasonable amount of detail, both on the methods and results in PSA:s performed and on the numerous supporting research programs dealing with various aspects of PSA. 39 refs 39 refs

  5. Status and use of PSA in Sweden

    Energy Technology Data Exchange (ETDEWEB)

    Knochenhauer, M

    1996-05-01

    The performance and use of PSA:s in Sweden goes back about two decades. During all of this time, the field of PSA has been developing intensively, both internationally and within Sweden. The latest years have been characterised by an increased use of PSA models and results, and by major extensions of existing PSA models. The aim of this document is to describe PSA in Sweden with respect to development, scope and maturity, as well as to the contents of the analyses and the use of results. PSA activities will be described from the point of view of both the authorities and the utilities. The report gives an overview of the development within the area of PSA in Sweden both its history and current trends. The aim has been to include a reasonable amount of detail, both on the methods and results in PSA:s performed and on the numerous supporting research programs dealing with various aspects of PSA. 39 refs 39 refs.

  6. Model engineering in a modular PSA

    International Nuclear Information System (INIS)

    Friedlhuber, Thomas

    2014-01-01

    For the purpose of PSA (Probabilistic Safety Analysis) for complex industrial systems, often PSA models in the form of fault and event trees are developed to model the risk of unwanted situations (hazards). While the recent decades, PSA models have gained high acceptance and have been developed massively. This lead to an increase in model sizes and complexity. Today, PSA models are often difficult to understand and maintain. This manuscript presents the concept of a modular PSA. A modular PSA tries to cope with the increased complexity by the techniques of modularization and instantiation. Modularization targets to treat a model by smaller pieces (the 'modules') to regain control over models. Instantiation aims to configure a generic model to different contexts. Both try to reduce model complexity. A modular PSA proposes new functionality to manage PSA models. Current model management is rather limited and not efficient. This manuscript shows new methods to manage the evolutions (versions) and deviations (variants) of PSA models in a modular PSA. The concepts of version and variant management are presented in this thesis. In this context, a model comparison and fusion of PSA models is precised. Model comparison provides important feedback to model engineers and model fusion kind of combines the work from different model engineers (concurrent model engineering). Apart from model management, methods to understand the content of PSA models are presented. The methods focus to highlight the dependencies between modules rather than their contents. Dependencies are automatically derived from a model structure. They express relations between model objects (for example a fault tree may have dependencies to basic events). To visualize those dependencies (for example in form of a model cartography) can constitute a crucial aid to model engineers for understanding complex interrelations in PSA models. Within the scope of this thesis, a software named 'Andromeda' has been

  7. Radiographic progression with nonrising PSA in metastatic castration-resistant prostate cancer: post hoc analysis of PREVAIL.

    Science.gov (United States)

    Bryce, A H; Alumkal, J J; Armstrong, A; Higano, C S; Iversen, P; Sternberg, C N; Rathkopf, D; Loriot, Y; de Bono, J; Tombal, B; Abhyankar, S; Lin, P; Krivoshik, A; Phung, D; Beer, T M

    2017-06-01

    Advanced prostate cancer is a phenotypically diverse disease that evolves through multiple clinical courses. PSA level is the most widely used parameter for disease monitoring, but it has well-recognized limitations. Unlike in clinical trials, in practice, clinicians may rely on PSA monitoring alone to determine disease status on therapy. This approach has not been adequately tested. Chemotherapy-naive asymptomatic or mildly symptomatic men (n=872) with metastatic castration-resistant prostate cancer (mCRPC) who were treated with the androgen receptor inhibitor enzalutamide in the PREVAIL study were analyzed post hoc for rising versus nonrising PSA (empirically defined as >1.05 vs ⩽1.05 times the PSA level from 3 months earlier) at the time of radiographic progression. Clinical characteristics and disease outcomes were compared between the rising and nonrising PSA groups. Of 265 PREVAIL patients with radiographic progression and evaluable PSA levels on the enzalutamide arm, nearly one-quarter had a nonrising PSA. Median progression-free survival in this cohort was 8.3 months versus 11.1 months in the rising PSA cohort (hazard ratio 1.68; 95% confidence interval 1.26-2.23); overall survival was similar between the two groups, although less than half of patients in either group were still at risk at 24 months. Baseline clinical characteristics of the two groups were similar. Non-rising PSA at radiographic progression is a common phenomenon in mCRPC patients treated with enzalutamide. As restaging in advanced prostate cancer patients is often guided by increases in PSA levels, our results demonstrate that disease progression on enzalutamide can occur without rising PSA levels. Therefore, a disease monitoring strategy that includes imaging not entirely reliant on serial serum PSA measurement may more accurately identify disease progression.

  8. GLUCOSE AND TOTAL PROTEIN LEVEL IN LABORATORY RATS UNDER CONDITIONS OF SHORT-TERM FASTING

    Directory of Open Access Journals (Sweden)

    Damir Suljević

    2013-09-01

    Full Text Available Glucose level (UV enzymatic method and total protein level (Biuret method were measured in the blood samples of the rats exposed to short-term starvation. We found a statistically significant increase in the glucose level in experimental animals during starvation, which is also evident in males and females in the experimental group (p <0.05, while decrease in the total protein level was not statistically significant. During starvation, more significant weight loss was observed in females compared to males.Key words: glucose, total protein, serum, Rattus

  9. Too Much Sodium PSA (:60)

    Centers for Disease Control (CDC) Podcasts

    2012-02-07

    This 60 second PSA is based on the February 2012 CDC Vital Signs report. Ninety percent of Americans age two and older eat too much sodium which can increase your risk for high blood pressure and often leads to heart disease and stroke, two leading causes of death in the US. Learn several small steps you can take to reduce the amount of sodium in your diet.  Created: 2/7/2012 by Centers for Disease Control and Prevention (CDC).   Date Released: 2/7/2012.

  10. The PSA assessment of Defense in Depth Memorandum and proposals

    International Nuclear Information System (INIS)

    Fiorini, Gian-Luigi; La Rovere, Stefano

    2016-01-01

    This report concerns the peculiar roles of the Defence-in-Depth (DiD) concept and the Probabilistic Safety Assessment (PSA) approach for the optimization of the safety performances of the nuclear installation. It proposes a conceptual framework and related process for the assessment of the 'safety architecture' implementing DiD, which is articulated in four main steps devoted to (1) the formulation of the safety objectives, (2) the identification of loads and environmental conditions, (3) the representation of the safety architecture and (4) the evaluation of the physical performance and reliability of the levels of DiD. A final additional step achieves the practical assessment of the safety architecture and the corresponding DiD with the support of the PSA. The comprehensive safety assessment of the implemented architecture needs its multi-dimensional representation, i.e. for given initiating event, sequence of possible failures, affected safety function and level of DiD. The risk space (frequency/probability of occurrence, versus consequences) is the framework for the integration between the DiD concept and the PSA approach. Additional qualitative key-notions are introduced in order to address the compliance of the safety architecture with a number of international safety requirements. In this context, the role of the PSA is no longer limited to the verification of the fulfilment of probabilistic targets but includes different contributions to the assessment of the DiD identified in this report. (authors)

  11. Total levels of hippocampal histone acetylation predict normal variability in mouse behavior.

    Directory of Open Access Journals (Sweden)

    Addie May I Nesbitt

    Full Text Available Genetic, pharmacological, and environmental interventions that alter total levels of histone acetylation in specific brain regions can modulate behaviors and treatment responses. Efforts have been made to identify specific genes that are affected by alterations in total histone acetylation and to propose that such gene specific modulation could explain the effects of total histone acetylation levels on behavior - the implication being that under naturalistic conditions variability in histone acetylation occurs primarily around the promoters of specific genes.Here we challenge this hypothesis by demonstrating with a novel flow cytometry based technique that normal variability in open field exploration, a hippocampus-related behavior, was associated with total levels of histone acetylation in the hippocampus but not in other brain regions.Results suggest that modulation of total levels of histone acetylation may play a role in regulating biological processes. We speculate in the discussion that endogenous regulation of total levels of histone acetylation may be a mechanism through which organisms regulate cellular plasticity. Flow cytometry provides a useful approach to measure total levels of histone acetylation at the single cell level. Relating such information to behavioral measures and treatment responses could inform drug delivery strategies to target histone deacetylase inhibitors and other chromatin modulators to places where they may be of benefit while avoiding areas where correction is not needed and could be harmful.

  12. PSA-based evaluation and rating of operational events

    International Nuclear Information System (INIS)

    Gomez Cobo, A.

    1997-01-01

    The presentation discusses the PSA-based evaluation and rating of operational events, including the following: historical background, procedures for event evaluation using PSA, use of PSA for event rating, current activities

  13. Serum levels of total IgE and soluble CD23 in bronchial asthma

    Directory of Open Access Journals (Sweden)

    G. Di Lorenzo

    1996-01-01

    Full Text Available The aim of the present study was to compare, during the pollen season, serum levels of total IgE and soluble CD23 (sCD23 from patients with allergic bronchial asthma, with those from healthy subjects. Significantly higher levels of total IgE and sCD23 were found in patients with asthma compared to the control group. Both in normal controls and in asthmatic patients, a significant correlation was shown between the levels of these two molecules. In asthmatic patients, significant correlations were found for both total IgE and sCD23, with lung function measured as bronchial responsiveness to inhaled methacholine. These results suggest that in asthmatic patients, in addition to the study of total serum IgE levels, the assessment of sCD23 serum levels may be helpful in the evaluation of disease activity.

  14. Testing the variability of PSA expression by different human prostate cancer cell lines by means of a new potentiometric device employing molecularly antibody assembled on graphene surface

    International Nuclear Information System (INIS)

    Rebelo, Tânia S.C.R.; Noronha, João P.; Galésio, Marco; Santos, Hugo; Diniz, Mário; Sales, M. Goreti F.; Fernandes, Maria H.; Costa-Rodrigues, João

    2016-01-01

    Prostate Specific Antigen (PSA) is widely used as a biomarker for prostate cancer. Recently, an electrochemical biosensor for PSA detection by means of molecularly imprinted polymers (MIPs) was developed. This work evaluated the performance and the effectiveness of that PSA biosensor in screening the biomarker PSA in biological media with complex composition, collected from different human prostate cell line cultures. For that, the prostate cancer LNCaP and PC3 cells, and the non-cancerous prostate cell line PNT2 were cultured for 2, 7 and 14 days in either α-MEM or RPMI in the presence of 10% or 30% fetal bovine serum. Human gingival fibroblasts were used as a non-cancerous non-prostatic control. The different culture conditions modulated cellular proliferation and the expression of several prostate markers, including PSA. The electrochemical biosensor was able to specifically detect PSA in the culture media and values obtained were similar to those achieved by a commercial Enzyme-Linked Immunosorbent Assay (ELISA) kit, the most commonly used method for PSA quantification in prostate cancer diagnosis. Thus, the tested biosensor may represent a useful alternative as a diagnostic tool for PSA determination in biological samples. - Highlights: • PSA quantification was performed in prostate cancer cell culture media. • Culture media composition and culture period significantly affect PSA production. • The PSA biosensor detected a wide range of PSA levels in complex media. • A high data correlation was observed between the biosensor and the ELISA analysis.

  15. Testing the variability of PSA expression by different human prostate cancer cell lines by means of a new potentiometric device employing molecularly antibody assembled on graphene surface

    Energy Technology Data Exchange (ETDEWEB)

    Rebelo, Tânia S.C.R. [BioMark-CINTESIS/ISEP, Instituto Superior de Engenharia do Instituto Politécnico do Porto (Portugal); LAQV, REQUIMTE, Departamento de Química, Faculdade de Ciências e Tecnologia, Universidade Nova de Lisboa, Caparica (Portugal); Laboratory for Bone Metabolism and Regeneration, Faculdade de Medicina Dentária, Universidade do Porto, Porto (Portugal); Noronha, João P.; Galésio, Marco; Santos, Hugo; Diniz, Mário [LAQV, REQUIMTE, Departamento de Química, Faculdade de Ciências e Tecnologia, Universidade Nova de Lisboa, Caparica (Portugal); Sales, M. Goreti F. [BioMark-CINTESIS/ISEP, Instituto Superior de Engenharia do Instituto Politécnico do Porto (Portugal); Fernandes, Maria H. [Laboratory for Bone Metabolism and Regeneration, Faculdade de Medicina Dentária, Universidade do Porto, Porto (Portugal); Costa-Rodrigues, João, E-mail: jrodrigues@fmd.up.pt [Laboratory for Bone Metabolism and Regeneration, Faculdade de Medicina Dentária, Universidade do Porto, Porto (Portugal); ESTSP — Escola Superior de Tecnologia da Saúde do Porto, Instituto Politécnico do Porto (Portugal)

    2016-02-01

    Prostate Specific Antigen (PSA) is widely used as a biomarker for prostate cancer. Recently, an electrochemical biosensor for PSA detection by means of molecularly imprinted polymers (MIPs) was developed. This work evaluated the performance and the effectiveness of that PSA biosensor in screening the biomarker PSA in biological media with complex composition, collected from different human prostate cell line cultures. For that, the prostate cancer LNCaP and PC3 cells, and the non-cancerous prostate cell line PNT2 were cultured for 2, 7 and 14 days in either α-MEM or RPMI in the presence of 10% or 30% fetal bovine serum. Human gingival fibroblasts were used as a non-cancerous non-prostatic control. The different culture conditions modulated cellular proliferation and the expression of several prostate markers, including PSA. The electrochemical biosensor was able to specifically detect PSA in the culture media and values obtained were similar to those achieved by a commercial Enzyme-Linked Immunosorbent Assay (ELISA) kit, the most commonly used method for PSA quantification in prostate cancer diagnosis. Thus, the tested biosensor may represent a useful alternative as a diagnostic tool for PSA determination in biological samples. - Highlights: • PSA quantification was performed in prostate cancer cell culture media. • Culture media composition and culture period significantly affect PSA production. • The PSA biosensor detected a wide range of PSA levels in complex media. • A high data correlation was observed between the biosensor and the ELISA analysis.

  16. [PSA interest and prostatitis: literature review].

    Science.gov (United States)

    Bruyère, F; Amine Lakmichi, M

    2013-12-01

    Prostatitis is easily diagnosed but sometimes associated with PSA measurement. An increased PSA in an asymptomatic patient may be associated with antibiotic use to eliminate the inflammatory part and to confirm prostate biopsy. It seems interesting to confirm or infirm these attitudes with a systematic review of the literature We performed a literature review using the words [prostatitis], [acute prostatitis], [prostate specific antigen], [PSA], in the MEDLINE, Pubmed and AMBASE database searching for articles in French or English published in the past 20 years. PSA is not always increased during an acute prostatitis episode. An increased PSA in an asymptomatic man does not seem to be systematically correlated to prostate inflammation. Analyzing the studies, it seems inaccurate to measure PSA value during a febrile urinary infection episode in men. Systematic use of antibiotic to decrease PSA and not performing prostate biopsy is not relevant and may induce resistance to antibiotic and doesn't induce a reduction risk of having prostate biopsy. PSA is unnecessary in case of febrile urinary tract infection in men. Copyright © 2013 Elsevier Masson SAS. All rights reserved.

  17. Performance of serum prostate-specific antigen isoform [-2]proPSA (p2PSA) and the prostate health index (PHI) in a Chinese hospital-based biopsy population.

    Science.gov (United States)

    Na, Rong; Ye, Dingwei; Liu, Fang; Chen, Haitao; Qi, Jun; Wu, Yishuo; Zhang, Guiming; Wang, Meilin; Wang, Wenying; Sun, Jielin; Yu, Guopeng; Zhu, Yao; Ren, Shancheng; Zheng, S Lilly; Jiang, Haowen; Sun, Yinghao; Ding, Qiang; Xu, Jianfeng

    2014-11-01

    The use of serum [-2]proPSA (p2PSA) and its derivative, the prostate health index (PHI), in detecting prostate cancer (PCa) have been consistently shown to have better performance than total prostate-specific antigen (tPSA) in discriminating biopsy outcomes in western countries. However, little is known about their performance in Chinese men. Our objective is to test the performance of p2PSA and PHI and their added value to tPSA in discriminating biopsy outcomes in Chinese men. Consecutive patients who underwent prostate biopsy in three tertiary hospitals in Shanghai, China during 2012-2013 were recruited. Serum tPSA, free PSA (fPSA), and p2PSA were measured centrally using Beckman Coulter's DxI 800 Immunoassay System. The primary outcome is PCa and the secondary outcome is high-grade PCa (Gleason Score of 4 + 3 or worse). Discriminative performance was assessed using the area under the receiver operating characteristic curve (AUC), detection rate and Decision Curve Analysis (DCA). Among 636 patients who underwent prostate biopsy, PHI was a significant predictor of biopsy outcomes, independent of other clinical variables. The AUC in discriminating PCa from non-PCa was consistently higher for PHI than tPSA in the entire cohort (0.88 vs. 0.81) as well as in patients with tPSA at 2-10 ng/ml (0.73 vs. 0.53), at 10.1-20 ng/ml (0.81 vs. 0.58), and at tPSA >20 ng/ml (0.90 vs. 0.80). The differences were statistically significant in all comparisons, P prostate biopsy in China. © 2014 Wiley Periodicals, Inc.

  18. Is there any relationship between serum levels of total bilirubin and the severity of erectile dysfunction?

    Science.gov (United States)

    Keskin, Ercüment; Karabakan, Mehmet; Bozkurt, Aliseydi; Hirik, Erkan; Karabulut, İbrahim; Gunay, Murat; Çakan, Murat

    2018-04-01

    Recent studies have shown that atherosclerosis is associated with erectile dysfunction and the serum bilirubin level. In this study, the serum total bilirubin levels of patients with erectile dysfunction were measured to investigate the relationship between the levels of erectile dysfunction and total bilirubin. A total of 94 patients with erectile dysfunction were divided into three groups; severe erectile dysfunction (33 patients), moderate erectile dysfunction (31 patients), and mild erectile dysfunction (30 patients). In addition, a control group was formed with 31 healthy men. The International Index of Erectile Function-5 Questionnaire was used to measure the quality of erection in all the groups. The body mass index was calculated for all the participants. The serum glucose, low-density lipoprotein and high-density lipoprotein, cholesterol, triglyceride, total bilirubin, and total testosterone levels were also determined. No statistically significant difference was observed between the groups in terms of the mean age, hypertension, smoking status, alcohol use, cardiovascular diseases, hepatobiliary disease, diabetes mellitus, and levels of total testosterone, low-density lipoprotein-cholesterol, and triglyceride. However, high-density lipoprotein, body mass index, and total bilirubin were significantly lower compared to the control group (p < 0.001). The serum total bilirubin level was found to be 0.41 ± 0.21 ng/dL in the severe erectile dysfunction, 0.43 ± 0.19 ng/dL in the moderate erectile dysfunction, and 0.48 ± 0.11 ng/dL in the mild erectile dysfunction groups (p < 0.001). Considering the significant differences between the erectile dysfunction and control groups in terms of serum total bilirubin levels, a low level of bilirubin may have a role in the etiology of erectile dysfunction.

  19. Outcomes after radical prostatectomy in the PSA era

    International Nuclear Information System (INIS)

    Scardino, Peter T.

    1996-01-01

    This year 317,000 men will be diagnosed with prostate cancer and 41,400 will die of this disease. Prostate cancer will kill nearly 1 million men alive today who are now over 50 years old. Since the mortality rate from prostate cancer increases more rapidly with age than any other cancer, and the most rapidly growing segment of the population is those > 80 years old, and mortality from other causes is declining, the number of deaths from prostate cancer is expected to increase inexorably for many years. Among the clinical prognostic factors that have been established as important predictors of the natural history of prostate cancer in conservatively treated patients, none is more important than the grade of the tumor. A similar influence of grade has been reported in patients treated surgically. At Baylor we assessed a variety of clinical prognostic factors in 728 men treated with radical prostatectomy and followed with serial PSA levels with no other therapy before proven recurrence of the cancer. While a variety of factors were significant in univariate analyses, in multivariate analysis only grade and serum PSA levels were significant clinical prognostic factors. Once the prostate was removed and pathologic information was available, however, pathologic stage became the most important factor (especially seminal vesicle or lymph node involvement), but Gleason grade was also a powerful independent factor. Surgical margin status and the presence of extracapsular extension were also independent predictors of recurrence, but total tumor volume added little additional information. Once the pathological information is available, none of the prognostic factors known before the operation, including PSA, PSA density, and clinical, have any independent power to predict prognosis. While radical prostatectomy may carry greater risk of complications than radiotherapy, its major advantage is the high probability that the cancer can be completely eradicated, especially if it is

  20. Total and antigen-specific Ige levels in umbilical cord blood

    Directory of Open Access Journals (Sweden)

    Sybilski AJ

    2009-12-01

    Full Text Available Abstract The present study was conducted to learn whether the perinatal and environmental factors could influence the total and antigen-specific IgE levels in umbilical cord blood. Retrospective data were obtained from 173 mother-infant pairs. Total and specific (for children's food, wheat/grass and house dust mite-HDM cord blood IgE levels were determined using the immunoassay test. The total cord blood IgE was between 0.0-23.08 IU/ml (mean 0.55 ± 2.07 IU/ml; median 0.16 IU/ml. Total IgE levels were significantly higher in boys compared with girls (OR = 2.2; P = 0.007, and in newborns with complicated pregnancy (OR = 2.7; P = 0.003. A greater number of siblings correlated with increases in the total cord blood IgE (P

  1. A Diet, Physical Activity, and Meditation Intervention in Men With Rising Prostate-Specific Antigen (PSA)

    National Research Council Canada - National Science Library

    Hebert, James R

    2006-01-01

    ... physical activity and mindfulness-based stress reduction. This randomized trial will enroll 60 men with rising PSA levels along with a partner of their choice, half of whom will be randomized to the intervention and half to usual care...

  2. A Diet, Physical Activity, and Meditation Intervention in Men With Rising Prostate-Specific Antigen (PSA)

    National Research Council Canada - National Science Library

    Hebert, James R

    2007-01-01

    ... physical activity and mindfulness-based stress reduction. This randomized trial will enroll 60 men with rising PSA levels along with a partner of their choice, half of whom will be randomized to the intervention and half to usual care...

  3. A Diet, Physical Activity, and Mediation Intervention in Men With Rising Prostate-Specific Antigen (PSA)

    National Research Council Canada - National Science Library

    Hebert, James

    2004-01-01

    ... physical activity and mindfulness-based stress reduction. This randomized trial will enroll 60 men with rising PSA levels along with a partner of their choice, half of whom will be randomized to the intervention and half to usual care...

  4. utility of prostate specific antigen (psa) in the indigenous african man

    African Journals Online (AJOL)

    diagnosed with Acute Prostatitis, Benign Prostate Hyperplasia (BPH) and Prostate. Cancer in ... Conclusions: The indigenous black African man has high levels of PSA even in benign ... to have other non-prostatic causes of bladder outlet.

  5. Development of the fire PSA methodology and the fire analysis computer code system

    International Nuclear Information System (INIS)

    Katsunori, Ogura; Tomomichi, Ito; Tsuyoshi, Uchida; Yusuke, Kasagawa

    2009-01-01

    Fire PSA methodology has been developed and was applied to NPPs in Japan for power operation and LPSD states. CDFs of preliminary fire PSA for power operation were the higher than that of internal events. Fire propagation analysis code system (CFAST/FDS Network) was being developed and verified thru OECD-PRISME Project. Extension of the scope for LPSD state is planned to figure out the risk level. In order to figure out the fire risk level precisely, the enhancement of the methodology is planned. Verification and validation of phenomenological fire propagation analysis code (CFAST/FDS Network) in the context of Fire PSA. Enhancement of the methodology such as an application of 'Electric Circuit Analysis' in NUREG/CR-6850 and related tests in order to quantify the hot-short effect precisely. Development of seismic-induced fire PSA method being integration of existing seismic PSA and fire PSA methods is ongoing. Fire PSA will be applied to review the validity of fire prevention and mitigation measures

  6. Correlation of Peripheral Vein Tumour Marker Levels, Internal Iliac Vein Tumour Marker Levels and Radical Prostatectomy Specimens in Patients with Prostate Cancer and Borderline High Prostate-Specific Antigen: A Pilot Study

    Energy Technology Data Exchange (ETDEWEB)

    Farrelly, Cormac, E-mail: farrellycormac@gmail.com [Hospital of the University of Pennsylvania, Perelman School of Medicine at the University of Pennsylvania, Division of Interventional Radiology, Department of Radiology (United States); Lal, Priti [University of Pennsylvania Perelman School of Medicine, Department of Pathology and Laboratory Medicine (United States); Trerotola, Scott O.; Nadolski, Gregory J.; Watts, Micah M. [Hospital of the University of Pennsylvania, Perelman School of Medicine at the University of Pennsylvania, Division of Interventional Radiology, Department of Radiology (United States); Gorrian, Catherine Mc. [Mater Misericordiae University Hospital, University College Dublin School of Medicine & Medical Science (Ireland); Guzzo, Thomas J. [University of Pennsylvania Perelman School of Medicine, Department of Urology and Surgery (United States)

    2016-05-15

    PurposeTo correlate prostate-specific antigen (PSA), free to total PSA percentage (fPSA%) and prostatic acid phosphatase (PAP) levels from peripheral and pelvic venous samples with prostatectomy specimens in patients with prostate adenocarcinoma and borderline elevation of PSA.Materials and MethodsIn this prospective institutional review board approved study, 7 patients with biopsy proven prostate cancer had a venous sampling procedure prior to prostatectomy (mean 3.2 days, range 1–7). Venous samples were taken from a peripheral vein (PVS), the right internal iliac vein, a deep right internal iliac vein branch, left internal iliac vein and a deep left internal iliac vein branch. Venous sampling results were compared to tumour volume, laterality, stage and grade in prostatectomy surgical specimens.ResultsMean PVS PSA was 4.29, range 2.3–6 ng/ml. PSA and PAP values in PVS did not differ significantly from internal iliac or deep internal iliac vein samples (p > 0.05). fPSA% was significantly higher in internal iliac (p = 0.004) and deep internal iliac (p = 0.003) vein samples compared to PVS. One of 7 patients had unilateral tumour only. This patient, with left–sided tumour, had a fPSA% of 6, 6, 6, 14 and 12 in his peripheral, right internal iliac, deep right internal iliac branch, left internal iliac and deep left internal iliac branch samples respectively. There were no adverse events.ConclusionfPSA%, unlike total PSA or PAP, is significantly higher in pelvic vein compared to peripheral vein samples when prostate cancer is present. Larger studies including patients with higher PSA values are warranted to further investigate this counterintuitive finding.

  7. Correlation of Peripheral Vein Tumour Marker Levels, Internal Iliac Vein Tumour Marker Levels and Radical Prostatectomy Specimens in Patients with Prostate Cancer and Borderline High Prostate-Specific Antigen: A Pilot Study

    International Nuclear Information System (INIS)

    Farrelly, Cormac; Lal, Priti; Trerotola, Scott O.; Nadolski, Gregory J.; Watts, Micah M.; Gorrian, Catherine Mc.; Guzzo, Thomas J.

    2016-01-01

    PurposeTo correlate prostate-specific antigen (PSA), free to total PSA percentage (fPSA%) and prostatic acid phosphatase (PAP) levels from peripheral and pelvic venous samples with prostatectomy specimens in patients with prostate adenocarcinoma and borderline elevation of PSA.Materials and MethodsIn this prospective institutional review board approved study, 7 patients with biopsy proven prostate cancer had a venous sampling procedure prior to prostatectomy (mean 3.2 days, range 1–7). Venous samples were taken from a peripheral vein (PVS), the right internal iliac vein, a deep right internal iliac vein branch, left internal iliac vein and a deep left internal iliac vein branch. Venous sampling results were compared to tumour volume, laterality, stage and grade in prostatectomy surgical specimens.ResultsMean PVS PSA was 4.29, range 2.3–6 ng/ml. PSA and PAP values in PVS did not differ significantly from internal iliac or deep internal iliac vein samples (p > 0.05). fPSA% was significantly higher in internal iliac (p = 0.004) and deep internal iliac (p = 0.003) vein samples compared to PVS. One of 7 patients had unilateral tumour only. This patient, with left–sided tumour, had a fPSA% of 6, 6, 6, 14 and 12 in his peripheral, right internal iliac, deep right internal iliac branch, left internal iliac and deep left internal iliac branch samples respectively. There were no adverse events.ConclusionfPSA%, unlike total PSA or PAP, is significantly higher in pelvic vein compared to peripheral vein samples when prostate cancer is present. Larger studies including patients with higher PSA values are warranted to further investigate this counterintuitive finding.

  8. Correlation of Peripheral Vein Tumour Marker Levels, Internal Iliac Vein Tumour Marker Levels and Radical Prostatectomy Specimens in Patients with Prostate Cancer and Borderline High Prostate-Specific Antigen: A Pilot Study.

    Science.gov (United States)

    Farrelly, Cormac; Lal, Priti; Trerotola, Scott O; Nadolski, Gregory J; Watts, Micah M; Gorrian, Catherine Mc; Guzzo, Thomas J

    2016-05-01

    To correlate prostate-specific antigen (PSA), free to total PSA percentage (fPSA%) and prostatic acid phosphatase (PAP) levels from peripheral and pelvic venous samples with prostatectomy specimens in patients with prostate adenocarcinoma and borderline elevation of PSA. In this prospective institutional review board approved study, 7 patients with biopsy proven prostate cancer had a venous sampling procedure prior to prostatectomy (mean 3.2 days, range 1-7). Venous samples were taken from a peripheral vein (PVS), the right internal iliac vein, a deep right internal iliac vein branch, left internal iliac vein and a deep left internal iliac vein branch. Venous sampling results were compared to tumour volume, laterality, stage and grade in prostatectomy surgical specimens. Mean PVS PSA was 4.29, range 2.3-6 ng/ml. PSA and PAP values in PVS did not differ significantly from internal iliac or deep internal iliac vein samples (p > 0.05). fPSA% was significantly higher in internal iliac (p = 0.004) and deep internal iliac (p = 0.003) vein samples compared to PVS. One of 7 patients had unilateral tumour only. This patient, with left-sided tumour, had a fPSA% of 6, 6, 6, 14 and 12 in his peripheral, right internal iliac, deep right internal iliac branch, left internal iliac and deep left internal iliac branch samples respectively. There were no adverse events. fPSA%, unlike total PSA or PAP, is significantly higher in pelvic vein compared to peripheral vein samples when prostate cancer is present. Larger studies including patients with higher PSA values are warranted to further investigate this counterintuitive finding.

  9. Decision criteria in PSA applications

    International Nuclear Information System (INIS)

    Holmberg, J.E.; Pulkkinen, U.; Rosqvist, T.; Simola, K.

    2001-11-01

    Along with the adoption of risk informed decision making principles, the need for formal probabilistic decision rule or criteria has been risen. However, there are many practical and theoretical problems in the application of probabilistic criteria. One has to think what is the proper way to apply probabilistic rules together with deterministic ones and how the criteria are weighted with respect to each other. In this report, we approach the above questions from the decision theoretic point of view. We give a short review of the most well known probabilistic criteria, and discuss examples of their use. We present a decision analytic framework for evaluating the criteria, and we analyse how the different criteria behave under incompleteness or uncertainty of the PSA model. As the conclusion of our analysis we give recommendations on the application of the criteria in different decision situations. (au)

  10. Key Characteristics of Combined Accident including TLOFW accident for PSA Modeling

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Bo Gyung; Kang, Hyun Gook [KAIST, Daejeon (Korea, Republic of); Yoon, Ho Joon [Khalifa University of Science, Technology and Research, Abu Dhabi (United Arab Emirates)

    2015-05-15

    The conventional PSA techniques cannot adequately evaluate all events. The conventional PSA models usually focus on single internal events such as DBAs, the external hazards such as fire, seismic. However, the Fukushima accident of Japan in 2011 reveals that very rare event is necessary to be considered in the PSA model to prevent the radioactive release to environment caused by poor treatment based on lack of the information, and to improve the emergency operation procedure. Especially, the results from PSA can be used to decision making for regulators. Moreover, designers can consider the weakness of plant safety based on the quantified results and understand accident sequence based on human actions and system availability. This study is for PSA modeling of combined accidents including total loss of feedwater (TLOFW) accident. The TLOFW accident is a representative accident involving the failure of cooling through secondary side. If the amount of heat transfer is not enough due to the failure of secondary side, the heat will be accumulated to the primary side by continuous core decay heat. Transients with loss of feedwater include total loss of feedwater accident, loss of condenser vacuum accident, and closure of all MSIVs. When residual heat removal by the secondary side is terminated, the safety injection into the RCS with direct primary depressurization would provide alternative heat removal. This operation is called feed and bleed (F and B) operation. Combined accidents including TLOFW accident are very rare event and partially considered in conventional PSA model. Since the necessity of F and B operation is related to plant conditions, the PSA modeling for combined accidents including TLOFW accident is necessary to identify the design and operational vulnerabilities.The PSA is significant to assess the risk of NPPs, and to identify the design and operational vulnerabilities. Even though the combined accident is very rare event, the consequence of combined

  11. Serum total prostate-specific antigen values in men with symptomatic prostate enlargement in Nigeria: role in clinical decision-making.

    Science.gov (United States)

    Nnabugwu, Ikenna I; Ugwumba, Fred O; Enivwenae, Oghenekaro A; Udeh, Emeka I; Otene, Chris O; Nnabugwu, Chinwe A

    2015-01-01

    Prostatic enlargement is a common cause of bladder outlet obstruction in men in Nigeria. Malignant enlargements must be differentiated from benign enlargements for adequate treatment of each patient. High serum total prostate-specific antigen (tPSA) levels suggest malignancy, but some of the biopsies done due to a serum tPSA value >4 ng/mL would be negative for malignancy because of the low specificity of tPSA for prostate cancer. This study aims to compare the histologic findings of all prostate specimens obtained from core needle biopsy, open simple prostatectomy, and transurethral resection of the prostate with the respective serum tPSA values in an attempt to decipher the role of serum tPSA in the management of these patients. The case notes of patients attended to from April 2009 to March 2012 were analyzed. Essentially, the age of the patient, findings on digital rectal examination, abdominopelvic ultrasonography report on the prostate, serum tPSA, and histology reports from biopsy or prostatectomy specimens as indicated were extracted for analysis. The relationship between age, findings on digital rectal examination, serum tPSA, abdominopelvic ultrasonography report, and histology are compared. A statistically significant relationship existed between a malignant histology and age 65 years and older, suspicious findings on digital rectal examination, suspicious ultrasonography findings, and serum tPSA >10 ng/mL, but not tPSA >4 ng/mL. In Nigerian patients with symptomatic prostate enlargement, serum tPSA should be seen as a continuum with increasing risk of prostate malignancy.

  12. Living PSA issues in France on pressurized water reactors

    International Nuclear Information System (INIS)

    Dewailly, J.; Deriot, S.; Dubreuil Chambardel, A.; Francois, P.; Magne, L.

    1993-09-01

    Two Probabilistic Safety Assessments (PSAs) carried out in France on 900 and 1300 MWe Pressurized Water Reactor units ended in 1990. These PSAs determined the core damage frequency for all plant operating conditions ranging from cold shutdown for refuelling to full power operation. Since 1990, these PSAs have been used increasingly as tools for applications such as accident precursor analysis, risk-based Technical Specifications, and maintenance optimization. In turn, these applications are used to enhance the initial PSAs. The notion of a ''living'' PSA which can be used and updated is slowly taking form. The accident precursor analysis consists in applying PSA event trees to obtain quick information on the potential consequences of a precursor event and on the corresponding probabilities of occurrence. A feedback on PSAs is provided by comparing them with actual operating incidents. The computation of the allowed outage time during power operation, based on the computerized models of Probabilistic Safety Assessments, requires adjustments: calculation of hourly risk of core damage under different reactor conditions without equipment unavailabilities. The proposed method also turns out to be an aid in determining the safe shutdown condition and procedure. Furthermore, when introducing a sufficient level of detail, PSA reliability models make it possible to compute contributions and to perform sensitivity studies in order to highlight those components for which a maintenance effort should be made. From the experience acquired up to now, there was felt to be a strong need to create guidelines for using PSAs that would simplify their implementation by the experts in charge of determining Technical Specifications, of maintenance programs, etc. who are not generally specialists in PSAs. For this purpose, it is necessary to improve the intelligibility of the models made in order for them to be used and to offer user's guides adapted to each application. Documents

  13. [Relationship between tumor volume and PSA recurrence after radical prostatectomy].

    Science.gov (United States)

    Hashimoto, Yasuhiro; Momose, Akishi; Okamoto, Akiko; Yamamoto, Hayato; Hatakeyama, Shingo; Iwabuchi, Ikuya; Yoneyama, Takahiro; Koie, Takuya; Kamimura, Noritaka; Ohyama, Chikara

    2010-02-01

    We examined whether the tumor volume (TV) is a good predictor of PSA recurrence after radical prostatectomy. Data were collected for 158 patients with clinically localized prostate cancer undergoing radical prostatectomy without neoadjuvant hormonal therapy in our hospital since April 2005 to September 2007. Along with the routine pathological assessment, TV was assessed in all prostatectomy specimens. PSA recurrence was defined as PSA levels of greater than 0.2 ng/ml. The TVs were 1.81+/-1.66 ml (mean +/-SD) ranging from 0.02 to 8.20 ml. The TV in cT1c was 1.77+/-1.64, and 1.89+/-1.72 ml in cT2 (not significant). Significant differences were observed between TV and pT. The TVs in pT2a, pT2b and pT3/4 were 0.54+/-0.54, 1.63+/-1.47 and 2.67+/-1.80 ml, respectively. The median follow-up period was 32.3 months (range from 15 to 45) after radical prostatectomy, and PSA recurrence was observed in 32 cases. Patients with smaller TV (TV TV (TV > or = 1.3 ml, 66.7%) with a significant difference atp TV, pT, Gleason Score (GS), and surgical margins. Significant differences were observed for GS, and surgical margins, but not for TV. Clinically organ-confined disease in Japanese patients with prostate cancer included various cancers from clinically insignificant to locally advanced ones. In our series, TV was not regarded as a predictor of PSA recurrence after radical prostatectomy.

  14. Comparison of global sensitivity analysis techniques and importance measures in PSA

    International Nuclear Information System (INIS)

    Borgonovo, E.; Apostolakis, G.E.; Tarantola, S.; Saltelli, A.

    2003-01-01

    This paper discusses application and results of global sensitivity analysis techniques to probabilistic safety assessment (PSA) models, and their comparison to importance measures. This comparison allows one to understand whether PSA elements that are important to the risk, as revealed by importance measures, are also important contributors to the model uncertainty, as revealed by global sensitivity analysis. We show that, due to epistemic dependence, uncertainty and global sensitivity analysis of PSA models must be performed at the parameter level. A difficulty arises, since standard codes produce the calculations at the basic event level. We discuss both the indirect comparison through importance measures computed for basic events, and the direct comparison performed using the differential importance measure and the Fussell-Vesely importance at the parameter level. Results are discussed for the large LLOCA sequence of the advanced test reactor PSA

  15. Radiographic progression with nonrising PSA in metastatic castration-resistant prostate cancer

    DEFF Research Database (Denmark)

    Bryce, A H; Alumkal, J J; Armstrong, A

    2017-01-01

    monitoring alone to determine disease status on therapy. This approach has not been adequately tested. METHODS: Chemotherapy-naive asymptomatic or mildly symptomatic men (n=872) with metastatic castration-resistant prostate cancer (mCRPC) who were treated with the androgen receptor inhibitor enzalutamide......BACKGROUND: Advanced prostate cancer is a phenotypically diverse disease that evolves through multiple clinical courses. PSA level is the most widely used parameter for disease monitoring, but it has well-recognized limitations. Unlike in clinical trials, in practice, clinicians may rely on PSA...... treated with enzalutamide. As restaging in advanced prostate cancer patients is often guided by increases in PSA levels, our results demonstrate that disease progression on enzalutamide can occur without rising PSA levels. Therefore, a disease monitoring strategy that includes imaging not entirely reliant...

  16. Técnica para obtenção do aparelho geniturinário e dosagem do PSA (Prostate Specific Antigen no hamster sírio, Mesocricetus auratus Technique for collecting blood for PSA (Prostate Specific Antigen dosing and genitourinary system obtaining in syrian hamster, Mesocricetus auratus

    Directory of Open Access Journals (Sweden)

    Dimas José Araújo Vidigal

    2004-12-01

    ículas seminais e testículos. Observou-se nos Hamsters adultos (n=20, setenta por cento de alterações nos anexos sexuais a saber: um caso (5% de processo supurativo das vesículas seminais, um caso (5% de processo inflamatório isolado das vesículas seminais, um caso (5% de Processo inflamatório das vesículas seminais, HBP e prostatite concomitante e um caso (5% de infarto testicular e prostatite. Onze animais (55%, dos Hamsters adultos, apresentaram HBP (Hiperplasia Benigna da Próstata. Conclusão: A técnica cirúrgica descrita mostrou-se eficiente para a obtenção dos orgãos e estruturas do aparelho geniturinário, estudo histológico desses orgãos e dosagem do PSA no Hamster Sírio, Mesocricetus auratus.Purpose: To explain the available technique in collecting blood for PSA (Prostate Specific Antigen dosing and the genitourinary system extracting from Syrian Hamster, Mesocricetus auratus, and correspond PSA findings to anexed sexual histologic changes. Methods: Thirty (n=30 Hamsters were used in the experiment: ten (n=10 animals were on the average age of 47,5 days on the decease mourent, being qualified as young and twenty ( n=20 animals over the age of one year were qualified as adults. After being under chetamina cloridate and diazepam anesthesia, on the superior abdomen level, c. 1,5mL to 2,0mL of blood were collected for total PSA dosing though ELISA method, with human antigen. They died after blood extracting. After verifying the animal death, laparatomy was carried out, extracting in complete monoblock the genitourinary system for a histologic study of sexual anexes. A PSA correlation was set with the found histologic changes. Results: An excellent anesthesian plan was obtained after shooting chetamina cloridate and diazepam intraperitoneum on the animals, that made possible to collect blood through the cava vein trans-derm via to the superior abdomen for the PSA dosing. The animal died after blood collecting. Laparatomy was carried out with the complete

  17. Insights of PSA studies made for operating nuclear power stations in Finland

    International Nuclear Information System (INIS)

    Laaksonen, J.; Virolainen, R.

    1991-01-01

    In 1984 the Finnish regulatory authority (STUK) required the utilities to make plant specific probabilistic safety assessment (PSA) studies for each plant. It was also strongly recommended that most of the work be made by plant personnel. This advice was well observed by both utilities. Results of level 1 PSA studies were submitted for regulatory review in June 1989. Only internal initiating events, including loss-of-offsite power and human errors, were considered at this stage. Each study took an effort of 12 to 20 man years. A thorough regulatory review, about two man years per plant, is currently underway, and will cause some changes in the initial results of the studies. The utilities are continuing their PSA work with the fire and flood analysis, and then with the analysis of risks during start-up and shutdown conditions. As soon as a level 1 PSA study has been reviewed, and a common understanding of the models and data has been reached between the utility and the STUK, this basic PSA version will be the first element of a living PSA. The second element is a user friendly PSA code that can rapidly run through the quantitative part of the study and thus easily indicate the influence of any deviation from the basic version. The third element is plant specific data collection and processing system. The living PSA for the first plant is expected to be fully operational sometime next year. The first use of the living PSA will be the safety assessment of proposed plant modifications and a systematic re-evaluation of technical specifications

  18. Serum total bilirubin levels and coronary heart disease--Causal association or epiphenomenon?

    Science.gov (United States)

    Kunutsor, Setor K

    2015-12-01

    Observational epidemiological evidence supports a linear inverse and independent association between serum total bilirubin levels and coronary heart disease (CHD) risk, but whether this association is causal remains to be ascertained. A Mendelian randomization approach was employed to test whether serum total bilirubin is causally linked to CHD. The genetic variant rs6742078--well known to specifically modify levels of serum total bilirubin and accounting for up to 20% of the variance in circulating serum total bilirubin levels--was used as an instrumental variable. In pooled analysis of estimates reported from published genome-wide association studies, every copy of the T allele of rs6742078 was associated with 0.42 standard deviation (SD) higher levels of serum total bilirubin (95% confidence interval, 0.40 to 0.43). Based on combined data from the Coronary Artery Disease Genome wide Replication and Meta-analyses and the Coronary Artery Disease (C4D) Genetics Consortium involving a total of 36,763 CHD cases and 76,997 controls, the odds ratio for CHD per copy of the T allele was 1.01 (95% confidence interval, 0.99 to 1.04). The odds ratio of CHD for a 1 SD genetically elevated serum total bilirubin level was 1.03 (95% confidence interval, 0.98 to 1.09). The current findings casts doubt on a strong causal association of serum total bilirubin levels with CHD. The inverse associations demonstrated in observational studies may be driven by biases such as unmeasured confounding and/or reverse causation. However, further research in large-scale consortia is needed. Copyright © 2015 Elsevier Inc. All rights reserved.

  19. Early Prediction of Therapy Response to Abiraterone Acetate Using PSA Subforms in Patients with Castration Resistant Prostate Cancer

    Directory of Open Access Journals (Sweden)

    Katrin Schlack

    2016-09-01

    Full Text Available The purpose of this study was to evaluate the prognostic ability of early changes of total prostate specific antigen (tPSA, free PSA (fPSA, [−2]proPSA and the Prostate Health Index (PHI following initiation of Abiraterone-therapy in men with castration resistant prostate cancer (mCRPC. In 25 patients, PSA-subforms were analyzed before and at 8–12 weeks under therapy as prognosticators of progression-free-survival (PFS and overall survival (OS. Comparing patients with a PFS < vs. ≥12 months by using Mann–Whitney–Wilcoxon Tests, the relative-median-change of tPSA (−0.1% vs. −86.8%; p = 0.02, fPSA (12.1% vs. −55.3%; p = 0.03 and [−2]proPSA (8.1% vs. −59.3%; p = 0.05 differed significantly. For men with ≤ vs. >15 months of OS there was a non-significant trend for a difference in the relative-median-change of fPSA (17.0% vs. −46.3%; p = 0.06. In Kaplan–Meier analyses, declining fPSA and [−2]proPSA were associated with a longer median PFS (13 months, 95% confidence interval (CI: 9.6–16.4 vs. 10 months, 95% CI: 3.5–16.5; p = 0.11, respectively. Correspondingly, decreasing fPSA and [−2]proPSA values indicated an OS of 32 months (95% CI: not reached (NR compared to 21 months in men with rising values (95% CI: 7.7–34.3; p = 0.14, respectively. We concluded that the addition of fPSA- and [−2]proPSA-changes to tPSA-information might be further studied as potential markers of early Abiraterone response in mCRPC patients.

  20. Total mercury levels in commercial fish species from Italian fishery and aquaculture.

    Science.gov (United States)

    Di Lena, Gabriella; Casini, Irene; Caproni, Roberto; Fusari, Andrea; Orban, Elena

    2017-06-01

    Total mercury levels were measured in 42 commercial fish species caught off the Central Adriatic and Tyrrhenian coasts of Italy and in 6 aquaculture species. The study on wild fish covered species differing in living habitat and trophic level. The study on farmed fish covered marine and freshwater species from intensive and extensive aquaculture and their feed. Mercury levels were analysed by thermal decomposition-amalgamation-atomic absorption spectrophotometry. Total mercury concentrations in the muscle of wild fish showed a high variability among species (0.025-2.20 mg kg -1 wet weight). The lowest levels were detected in low trophic-level demersal and pelagic-neritic fish and in young individuals of high trophic-level species. Levels exceeding the European Commission limits were found in large-size specimens of high trophic-level pelagic and demersal species. Fish from intensive farming showed low levels of total mercury (0.008-0.251 mg kg -1 ). Fish from extensive rearing showed variable contamination levels, depending on the area of provenience. An estimation of the human intake of mercury associated to the consumption of the studied fish and its comparison with the tolerable weekly intake is provided.

  1. Association between PSA kinetics and cancer-specific mortality in patients with localised prostate cancer: analysis of the placebo arm of the SPCG-6 study.

    Science.gov (United States)

    Thomsen, F B; Brasso, K; Berg, K D; Gerds, T A; Johansson, J-E; Angelsen, A; Tammela, T L J; Iversen, P

    2016-03-01

    The prognostic value of prostate-specific antigen (PSA) kinetics in untreated prostate cancer (PCa) patients is debatable. We investigated the association between PSA doubling time (PSAdt), PSA velocity (PSAvel) and PSAvel risk count (PSAvRC) and PCa mortality in a cohort of patients with localised PCa managed on watchful waiting. Patients with clinically localised PCa managed observationally, who were randomised to and remained on placebo for minimum 18 months in the SPCG-6 study, were included. All patients survived at least 2 years and had a minimum of three PSA determinations available. The prognostic value of PSA kinetics was analysed and patients were stratified according to their PSA at consent: ≤10, 10.1-25, and >25 ng/ml. Cumulative incidences of PCa-specific mortality were estimated with the Aalen-Johansen method. Two hundred and sixty-three patients were included of which 116, 76 and 71 had a PSA at consent ≤10, 10.1-25, and >25 ng/ml, respectively. Median follow-up was 13.6 years. For patients with PSA at consent between 10.1 and 25 ng/ml, the 13-year risks of PCa mortality were associated with PSA kinetics: PSAdt ≤3 years: 62.0% versus PSAdt >3 years: 16.3% (Gray's test: P PSA kinetics were significantly associated with changes of 13-year risks of PCa mortality in patients with PSA at consent ≤10 or >25 ng/ml. We found that magnitude changes in 13-year risks of PCa mortality that can be indicated by PSA kinetics depend on PSA level in patients with localised PCa who were managed observationally. Our results question PSA kinetics as surrogate marker for PCa mortality in patients with low and high PSA values. NCT00672282. © The Author 2015. Published by Oxford University Press on behalf of the European Society for Medical Oncology. All rights reserved. For permissions, please email: journals.permissions@oup.com.

  2. Total proteins and protein fractions levels in pregnant rats subjected to whole-body gamma irradiation

    International Nuclear Information System (INIS)

    Mansour, M.A.; Roushdy, H.M.; Mazhar, F.M.; Abu-Gabal, H.A.

    1986-01-01

    A total number of 180 mature rats (120 females and 60 males) weighing from 120-140 g were used to study the effect of two doses (2 and 4 Gy) whole-body gamma irradiation on the level of total protein and protein fractions in serum of pregnant rats during the period of organogenesis. It was found that the levels of total protein, albumin and gamma globulins significantly decreased according to the doses of exposure. The levels of alpha and beta globulins significantly increased more in the serum of rats exposed to 2 Gy than in rats exposed to 4 Gy. The level of A/G ratio significantly decreased more in the serum of rats exposed to 2Gy than in those exposed to 4 Gy

  3. Risk evaluations of aging: Procedures guide for an age-dependent PSA with emphasis on prioritization and sensitivity studies

    International Nuclear Information System (INIS)

    Vesely, W.E.

    1991-01-01

    Based on the previous work which has been performed in the project, a procedures guide is being developed for carrying out an age-dependent probabilistic safety assessment (PSA) for evaluating the core damage frequency with aging effects explicitly treated. A PSA is basically a Level 1 Probabilistic Risk Assessment (PRA). The emphasis of the guide is on prioritization and sensitivity studies. Focus is also on active components although consideration of aging effects in passive components is also treated. The guide is intended to become a NUREG/CR and is the first of three volumes which are being developed. The following topics with demonstrations and applications are described in the presentation: (1) the age-dependent PSA versus the standard PSA; (2) component reliability models used in an age-dependent PSA; (3) approaches for transforming a PSA into an age-dependent PSA; (4) application of an age-dependent PSA; (5) using a PSA to evaluate the risk effects from aging passive components; (6) evaluation of the risk importance of passive components; (7) prioritizations of aging contributors; (8) evaluations of test and maintenance effectiveness; and (9) sensitivity studies and uncertainty analyses of aging effects

  4. The clinical study of serum PSA and fPSA assayed by CLIA in diagnosing prostate disease

    International Nuclear Information System (INIS)

    Xiong Jiang; Qian Xiaoyu; Ji Hong; Yang Su; Ding Ying; Zhu Ruisen; Chen Zhong

    2003-01-01

    The purpose of this study is to evaluate the clinical value of PSA (prostate specific antigen) and fPSA(free prostate specific antigen) in differentiating prostate disease. CLIA was used to quantitatively assay PSA, fPSA and fPSA/PSA in 30 cases of normal controls, 32 cases of prostate cancer patients and 76 cases of BPH patients. The result showed that if liminal value of PSA was set at 4 ng/mL, the diagnostic sensitivity and specificity of prostate cancer were 100% and 50.6% respectively. Meanwhile, if liminal value of fPSA/PSA set at 16% was added, the diagnostic sensitivity and specificity of prostate cancer were 100% and 85.3% respectively. It was concluded that the combining assay of PSA and fPSA could increase the diagnostic specificity of prostate cancer in a certain degree

  5. PET/CT with (18)F-choline after radical prostatectomy in patients with PSA ≤2 ng/ml. Can PSA velocity and PSA doubling time help in patient selection?

    Science.gov (United States)

    Chiaravalloti, Agostino; Di Biagio, Daniele; Tavolozza, Mario; Calabria, Ferdinando; Schillaci, Orazio

    2016-07-01

    To investigate the performance of (18)F-fluorocholine ((18)F-FCH) PET/CT in relation to the prostate-specific antigen (PSA) kinetic indexes, PSA doubling time (PSAdt) and PSA velocity (PSAve), in detecting recurrent prostate cancer (PC) in a selected population of patients treated with radical prostatectomy and with PSA ≤2 ng/ml. The study group comprised 79 patients (mean age 70 ± 7 years, range 58 - 77 years) who had been treated with radical surgery 30 to 90 months previously and with biochemical failure (defined as a measurable serum PSA level) who were evaluated with (18)F-FCH PET/CT. In order to establish the optimal threshold for PSAdt and PSAve, the diagnostic performance of PSA, PSAdt and PSAve were compared by receiver operating characteristic analysis. In the population examined, PSA (mean ± SD) was 1.37 ± 0.44 ng/ml (range 0.21 - 2 ng/ml) before PET/CT examination, PSAdt was 10.04 ± 16.67 months and PSAve was 2.75 ± 3.11 ng/ml per year. (18)F-FCH PET/CT was positive in 44 patients (55 %). PSAve and PSAdt were significantly different between patients with a positive and a negative (18)F-FCH PET/CT scan. Thresholds of 6 months for PSAdt and 1 ng/ml per year for PSAve were selected. For PSAdt ≤6 months the detection rate (DR) was 65 %, and for PSAve >1 ng/ml per year the DR was 67 %. PSA values were not significantly different between patients with a positive and a negative PET/CT scan. The results of our study suggest that (18)F-FCH PET/CT could be considered for the evaluation of patients with biochemical recurrence of PC and with low PSA levels. Fast PSA kinetics could be useful in the selection of these patients.

  6. Is there any association between National Institute of Health category IV prostatitis and prostate-specific antigen levels in patients with low-risk localized prostate cancer?

    Science.gov (United States)

    Doluoglu, Omer Gokhan; Ceylan, Cavit; Kilinc, Fatih; Gazel, Eymen; Resorlu, Berkan; Odabas, Oner

    2016-01-01

    We investigated the association between National Institute of Health category IV prostatitis and prostate-specific antigen levels in patients with low-risk localized prostate cancer. The data of 440 patients who had undergone prostate biopsies due to high PSA levels and suspicious digital rectal examination findings were reviewed retrospectively. The patients were divided into two groups based on the presence of accompanying NIH IV prostatitis. The exclusion criteria were as follows: Gleason score>6, PSA level>20ng/mL, >2 positive cores, >50% cancerous tissue per biopsy, urinary tract infection, urological interventions at least 1 week previously (cystoscopy, urethral catheterization, or similar procedure), history of prostate biopsy, and history of androgen or 5-alpha reductase use. All patient's age, total PSA and free PSA levels, ratio of free to total PSA, PSA density and prostate volume were recorded. In total, 101 patients were included in the study. Histopathological examination revealed only PCa in 78 (77.2%) patients and PCa+NIH IV prostatitis in 23 (22.7%) patients. The median total PSA level was 7.4 (3.5-20.0) ng/mL in the PCa+NIH IV prostatitis group and 6.5 (0.6-20.0) ng/mL in the PCa group (p=0.67). The PSA level was≤10ng/mL in 60 (76.9%) patients in the PCa group and in 16 (69.6%) patients in the PCa+NIH IV prostatitis group (p=0.32). Our study showed no statistically significant difference in PSA levels between patients with and without NIH IV prostatitis accompanying PCa.

  7. PSA as a tool for decision making

    International Nuclear Information System (INIS)

    Niehaus, F.; Lederman, L.

    1986-01-01

    The question on ''How safe is safe enough'' is being responded presently by deterministic criteria. Probabilistic criteria in support to more rational and less emotional decisions in regulatory and licensing issues, rationalization of resource allocation and research prioritization, among others, have a potential which is only marginally being explored. This paper discussed PSA limitations and proposes three areas for the use of PSA in decision making, namely: preventing accidents, mitigating accidents, and defining regulatory requirements. Current activities of the International Atomic Energy Agency in these areas are mentioned. PSA studies depict clearly the uncertainties and this is viewed as a positive aspect, which is unique to the use of probabilistic methods. (orig.)

  8. PSA as a tool for decision making

    Energy Technology Data Exchange (ETDEWEB)

    Niehaus, F; Lederman, L

    1986-05-01

    The question on ''How safe is safe enough'' is being responded presently by deterministic criteria. Probabilistic criteria in support to more rational and less emotional decisions in regulatory and licensing issues, rationalization of resource allocation and research prioritization, among others, have a potential which is only marginally being explored. This paper discussed PSA limitations and proposes three areas for the use of PSA in decision making, namely: preventing accidents, mitigating accidents, and defining regulatory requirements. Current activities of the International Atomic Energy Agency in these areas are mentioned. PSA studies depict clearly the uncertainties and this is viewed as a positive aspect, which is unique to the use of probabilistic methods.

  9. FATORES DEMOGRÁFICOS ASSOCIADOS À REALIZAÇÃO DO ANTÍGENO PROSTÁTICO ESPECÍFICO (PSA EM MUNICÍPIO SUL BRASILEIRO

    Directory of Open Access Journals (Sweden)

    Willian Augusto Melo

    2012-12-01

    Full Text Available The Prostate Specific Antigen (PSA is considered the most important marker to detect, monitor and internship prostate cancer. This study aimed to characterize the men who were examined for measurement of PSA in 2009 in a basic health unit of Maringá-PR. Were collected information about age, race, PSA test result and place of residence. The independent variable was PSA values (normal or abnormal. Were used descriptive statistics of the variables through the frequencies and bivariate analysis by Fisher's Exact Test. Was reached that 53.5% of men who underwent PSA testing were younger than 60 years, where these, 1.2% had their PSA level abnormal or above 4.01 Ng-mL. Being over 70 years was statistically significant PSA changes. It is concluded that age is a triggering factor for benign and malignant prostatic abnormalities.

  10. Blood trihalomethane levels and the risk of total cancer mortality in US adults

    International Nuclear Information System (INIS)

    Min, Jin-Young; Min, Kyoung-Bok

    2016-01-01

    Background: Although animal data have suggested the carcinogenic activity of trihalomethanes (THMs), there is inconsistent evidence supporting the link between THM exposure and cancers in humans. Objectives: We investigated the association between specific and total blood THM levels with the risk of total cancer mortality in adults. Methods: We analyzed data from the 1999–2004 Third National Health and Nutrition Examination Survey and the Linked Mortality File of the United States. A total of 933 adults (20–59 years of age) with available blood THM levels and no missing data for other variables were included. Four different THM species (chloroform, bromodichloromethane (BDCM), dibromochloromethane (DBCM) and bromoform) were included, and the codes associated with cancer (malignant neoplasm) were C00 through C97, based on the underlying causes of death listed in the International Classification of Disease 10the Revision. Results: Compared with adults in the lowest DBCM, bromoform, and total brominated THM tertiles, those in the highest DBCM, bromoform, and total brominated THM tertiles exhibited adjusted hazard ratios (HR) of total cancer mortality of 4.97 (95% confidence interval (CI) = 1.59–15.50), 4.94 (95% CI = 1.56–15.61), and 3.42 (95% CI = 1.21–15.43) respectively. The risk of total cancer mortality was not associated with increases in blood chloroform and total THM levels. Conclusions: We found that the baseline blood THM species, particularly brominated THMs, were significantly associated with total cancer mortality in adults. Although this study should be confirm by other studies, our findings suggest a possible link between THM exposures and cancer. - Highlights: • Trihalomethanes (THM) are classified as either probable or possible carcinogens. • Limited evidence on the link between THM and the incidence of cancer in humans. • We investigated the association between blood THM levels and the risk of total cancer mortality. • High

  11. PSA predicts development of incident lower urinary tract symptoms: results from the REDUCE study.

    Science.gov (United States)

    Patel, Devin N; Feng, Tom; Simon, Ross M; Howard, Lauren E; Vidal, Adriana C; Moreira, Daniel M; Castro-Santamaria, Ramiro; Roehrborn, Claus; Andriole, Gerald L; Freedland, Stephen J

    2018-05-23

    The relationship between baseline prostate-specific antigen (PSA) and development of lower urinary tract symptoms (LUTS) in asymptomatic and mildly symptomatic men is unclear. We sought to determine if PSA predicts incident LUTS in these men. A post-hoc analysis of the 4-year REDUCE study was performed to assess for incident LUTS in 1534 men with mild to no LUTS at baseline. The primary aim was to determine whether PSA independently predicted incident LUTS after adjusting for the key clinical variables of age, prostate size, and baseline International prostate symptom score (IPSS). Incident LUTS was defined as the first report of medical treatment, surgery, or sustained clinically significant symptoms (two IPSS >14). Cox proportional hazards, cumulative incidence curves, and the log-rank test were used to test our hypothesis. A total of 1534 men with baseline IPSS PSA 2.5-4 ng/mL, 589 with PSA 4.1-6 ng/mL, and 610 with PSA 6-10 ng/mL. During the 4-year study, 196 men progressed to incident LUTS (50.5% medical treatment, 9% surgery, and 40.5% new symptoms). As a continuous variable, higher PSA was associated with increased incident LUTS on univariable (HR 1.09, p = 0.019) and multivariable (HR 1.08, p = 0.040) analysis. Likewise, baseline PSA 6-10 ng/mL was associated with increased incident LUTS vs. PSA 2.5-4 ng/mL in adjusted models (HR 1.68, p = 0.016). This association was also observed in men with PSA 4.1-6 ng/mL vs. PSA 2.5-4 ng/mL (HR 1.60, p = 0.032). Men with mild to no LUTS but increased baseline PSA are at increased risk of developing incident LUTS presumed due to benign prostatic hyperplasia.

  12. PSA doubling time of prostate carcinoma managed with watchful observation alone

    International Nuclear Information System (INIS)

    Choo, Richard; DeBoer, Gerrit; Klotz, Lawrence; Danjoux, Cyril; Morton, Gerard C.; Rakovitch, Eileen; Fleshner, Neil; Bunting, Peter; Kapusta, Linda; Hruby, George

    2001-01-01

    Purpose: To study prostate-specific antigen (PSA) doubling time of untreated, favorable grade, prostate carcinoma. Methods and Materials: A prospective single-arm cohort study has been in progress to assess the feasibility of a watchful observation protocol with selective delayed intervention using clinical, histologic, or PSA progression as treatment indication in untreated, localized, favorable grade prostate adenocarcinoma (T1b-T2bN0 M0, Gleason Score ≤7, and PSA ≤15 ng/mL). Patients are conservatively managed with watchful observation alone, as long as they do not meet the arbitrarily defined disease progression criteria. Patients are followed regularly and undergo blood tests including PSA at each visit. PSA doubling time (Td) is estimated from a linear regression of ln(PSA) on time, assuming a simple exponential growth model. Results: As of March 2000, 134 patients have been on the study for a minimum of 12 months (median, 24; range, 12-52) and have a median frequency of PSA measurement of 7 times (range, 3-15). Median age is 70 years. Median PSA at enrollment is 6.3 (range, 0.5-14.6). The distribution of Td is as follows: 50 years, 27. The median Td is 5.1 years. In 44 patients (33%), Td is greater than 10 years. There was no correlation between Td and patient age, clinical T stage, Gleason score, or initial PSA level. Conclusion: Td of untreated prostate cancer varies widely. In our cohort, 33% have Td >10 years. Td may be a useful tool to guide treatment intervention for patients managed conservatively with watchful observation alone

  13. Determinations of total residue, total oxide and density of high-level liquid waste (HLLW) by gravimetric method

    International Nuclear Information System (INIS)

    Li Yun; Gao Yueying; Yang Ming; Jin Liyun

    1992-01-01

    Gravimetric method for determination of total residue, total oxide and density of HLLW is developed. An aliquot of the original HLLW solution is piped on to the small quartz disc and put into the mini muffle furnace carefully. It is first heated to below 100 degree C (for 1.5 hours to remove the free water, and then heated to 180 degree C for 2 hours to remove the crystal water in a furnace. The total residue is weighed at room temperature. The precision is better than 3% for the determination of total residue and total oxide. An aliquot of the original HLLW solution is piped into the weighing bottle and weighed. The precision is better than 1%

  14. Normal levels of total body sodium and chlorine by neutron activation analysis

    International Nuclear Information System (INIS)

    Kennedy, N.S.J.; Eastell, R.; Smith, M.A.; Tothill, P.

    1983-01-01

    In vivo neutron activation analysis was used to measure total body sodium and chlorine in 18 male and 18 female normal adults. Corrections for body size were developed. Normalisation factors were derived which enable the prediction of the normal levels of sodium and chlorine in a subject. The coefficient of variation of normalised sodium was 5.9% in men and 6.9% in women, and of normalised chlorine 9.3% in men and 5.5% in women. In the range examined (40-70 years) no significant age dependence was observed for either element. Total body sodium was correlated with total body chlorine and total body calcium. Sodium excess, defined as the amount of body sodium in excess of that associated with chlorine, also correlated well with total body calcium. In females there was a mean annual loss of sodium excess of 1.2% after the menopause, similar to the loss of calcium. (author)

  15. Probability of an Abnormal Screening PSA Result Based on Age, Race, and PSA Threshold

    Science.gov (United States)

    Espaldon, Roxanne; Kirby, Katharine A.; Fung, Kathy Z.; Hoffman, Richard M.; Powell, Adam A.; Freedland, Stephen J.; Walter, Louise C.

    2014-01-01

    Objective To determine the distribution of screening PSA values in older men and how different PSA thresholds affect the proportion of white, black, and Latino men who would have an abnormal screening result across advancing age groups. Methods We used linked national VA and Medicare data to determine the value of the first screening PSA test (ng/mL) of 327,284 men age 65+ who underwent PSA screening in the VA healthcare system in 2003. We calculated the proportion of men with an abnormal PSA result based on age, race, and common PSA thresholds. Results Among men age 65+, 8.4% had a PSA >4.0ng/mL. The percentage of men with a PSA >4.0ng/mL increased with age and was highest in black men (13.8%) versus white (8.0%) or Latino men (10.0%) (PPSA >4.0ng/mL ranged from 5.1% of Latino men age 65–69 to 27.4% of black men age 85+. Raising the PSA threshold from >4.0ng/mL to >10.0ng/mL, reclassified the greatest percentage of black men age 85+ (18.3% absolute change) and the lowest percentage of Latino men age 65–69 (4.8% absolute change) as being under the biopsy threshold (PPSA threshold together affect the pre-test probability of an abnormal screening PSA result. Based on screening PSA distributions, stopping screening among men whose PSA 10ng/ml has the greatest effect on reducing the number of older black men who will face biopsy decisions after screening. PMID:24439009

  16. Men presenting with prostate-specific antigen (PSA) values of over 100 ng/mL.

    Science.gov (United States)

    Ang, Mann; Rajcic, Branimir; Foreman, Darren; Moretti, Kim; O'Callaghan, Michael E

    2016-04-01

    To investigate overall survival and prostate cancer-specific mortality in men with prostate cancer presenting with a PSA level PSA level extracted from the South Australian Prostate Cancer Clinical Outcomes Collaborative (SA-PCCOC) database. Men included were diagnosed between January 1998 and August 2013. Patients were divided into groups according to diagnostic PSA level: 500 ng/mL. Outcomes measured include overall survival and prostate cancer-specific mortality. Clinical stage, Gleason score and the presence of bony metastasis was evaluated to determine if they were prognostic factors in patients with PSA over 100 at diagnosis. Cox proportional hazards and competing risks regression were used to model overall survival and prostate cancer-specific mortality outcomes respectively. Of this cohort, 241 patients (4.2%) had a diagnostic PSA level >100 ng/mL. Patients with PSA >100 ng/mL have a significant reduction in five (29.1% vs 62.5% vs 87%) and ten-year (18.2% vs 36.7% vs 70.7%) overall survival when compared to men with diagnostic PSA 20-100 and PSA level at diagnosis. Overall survival was associated with PSA level, Gleason score and age. There was a linear increase in risk (overall survival) as PSA increased until 200 and no association thereafter. Models of overall survival and prostate cancer-specific mortality incorporating a risk stratification developed by Izumi et al. predicted overall survival but not prostate cancer-specific mortality. The use of this stratification did not improve model accuracy. Only a small number of men (4.2%) with prostate cancer present with PSA >100 ng/mL at diagnosis. Overall survival at five and ten years was significantly poorer in patients with PSA >100 ng/mL. In this cohort of men presenting with PSA >100 at diagnosis, PSA level was not associated with prostate cancer-specific mortality. Gleason score and metastases are significant prognostic factors in this group of men. © 2016 The Authors BJU International © 2016

  17. Plasma levels of acylated and total ghrelin in pediatric patients with chronic kidney disease.

    Science.gov (United States)

    Naufel, Maria Fernanda Soares; Bordon, Milena; de Aquino, Talita Marques; Ribeiro, Eliane Beraldi; de Abreu Carvalhaes, João Tomás

    2010-12-01

    This cross-sectional study set out to compare total and acyl ghrelin levels in children with mild chronic kidney disease (CKD) undergoing conservative treatment (n = 19) with children with end-stage renal disease (ESRD) undergoing hemodialysis (n = 24), and with healthy controls (n = 20). The relationship between ghrelin levels and parameters of renal function, nutritional status, and selective hormones were investigated. ESRD patients had higher total ghrelin levels than those with mild CKD or control individuals. However, acyl ghrelin did not differ between groups, indicating that the excess circulating ghrelin was desacylated. Since desacyl ghrelin has been shown to inhibit appetite, increased levels might contribute to protein-energy wasting in pediatric renal patients. When all 43 renal patients were combined, multiple regression analysis found age and glomerular filtration rate (GFR) to be significant negative predictors of total ghrelin. Acyl ghrelin was influenced negatively by age and positively by energy intake. Acyl to total ghrelin ratio related positively to GFR and energy intake. The results indicate that total but not acyl ghrelin is influenced by low GFR in children with CKD and suggests that ghrelin activation may be impaired in these patients. Since energy intake is a positive predictor of acyl ghrelin, the physiological control of ghrelin secretion appears to be altered in pediatric renal patients.

  18. The effects of maternal total protein, albumin and hemoglobin levels on birth weight

    Directory of Open Access Journals (Sweden)

    Berna Haliloglu

    2007-12-01

    Full Text Available OBJECTIVE: The present study was designed to investigate the influence of third trimester maternal total protein, albumin, hemoglobin levels on birth weight.\tMATERIAL-METHOD: Between January 2005 and July 2005, 750 pregnant women applied for delivery at Zeynep Kamil Women’s and Children Education and Research Hospital at 37-40 week’s gestation were examined. Maternal total protein, albumin and hemoglobin levels were measured. Data included maternal age, gravidity, parity, gestational age, birth weight, gender, presence of iron supplementation and its duration.\tRESULTS: The birth weight was significantly higher in anemic and hypoproteinemic groups compared those with normal levels. After adjusting for counfounding factors, significance of both findings lost. The cases received iron supplementation had infants with higher birth weight, however, it was not statistically significant (p: 0.055. A significant positive relation was observed between birth weight and maternal age, gravidity, parity and gestational age. No relation found between maternal total protein, albumin, hemoglobin levels and birth weight.\tCONCLUSION: The last trimester maternal total protein, albumin, hemoglobin levels seem not to be a determining factor on infant's birth weight.

  19. More Adults Are Walking PSA (:60)

    Centers for Disease Control (CDC) Podcasts

    This 60 second PSA is based on the August 2012 CDC Vital Signs report. While more adults are walking, only half get the recommended amount of physical activity. Listen to learn how communities, employers, and individuals may help increase walking.

  20. A preliminary investigation of PSA validation methods

    Energy Technology Data Exchange (ETDEWEB)

    Unwin, S D [Science Applications International Corp., (United States)

    1995-09-01

    This document has been prepared to support the initial phase of the Atomic Energy Control Board`s program to review and evaluate Probabilistic Safety Assessment (PSA) studies conducted by nuclear generating station designers and licensees. The document provides (1) a review of current and prospective applications of PSA technology in the Canadian nuclear power industry; (2) an assessment of existing practices and techniques for the review or risk and hazard identification studies in the international nuclear power sector and other technological sectors; and (3) proposed analytical framework in which to develop systematic techniques for the scrutiny and evaluation of a PSA model. These frameworks are based on consideration of the mathematical structure of a PSA model and are intended to facilitate the development of methods to evaluate a model relative to intended end-uses. (author). 34 refs., 10 tabs., 3 figs.

  1. A preliminary investigation of PSA validation methods

    International Nuclear Information System (INIS)

    Unwin, S.D.

    1995-09-01

    This document has been prepared to support the initial phase of the Atomic Energy Control Board's program to review and evaluate Probabilistic Safety Assessment (PSA) studies conducted by nuclear generating station designers and licensees. The document provides (1) a review of current and prospective applications of PSA technology in the Canadian nuclear power industry; (2) an assessment of existing practices and techniques for the review or risk and hazard identification studies in the international nuclear power sector and other technological sectors; and (3) proposed analytical framework in which to develop systematic techniques for the scrutiny and evaluation of a PSA model. These frameworks are based on consideration of the mathematical structure of a PSA model and are intended to facilitate the development of methods to evaluate a model relative to intended end-uses. (author). 34 refs., 10 tabs., 3 figs

  2. PDS4 Challenges in the PSA

    Science.gov (United States)

    Saiz, J.; Barbarisi, I.; Docasal, R.; Rios, C.; Montero, A.; Macfarlane, A.; Laantee, C.; Besse, S.; Vallat, C.; Marcos, J.; Arenas, J.; Osinde, J.; Arviset, C.

    2018-04-01

    The Planetary Science Archive (PSA) stores products from all planetary ESA missions. Adopting PDS4 as the standard for new missions, while being compatible with existing PDS3 products, has driven a design with several difficulties to overcome.

  3. Proceedings of the 10th Korea-Japan joint workshop on PSA. For Asian PSA network

    International Nuclear Information System (INIS)

    Yang, Joon-Eon; Homma, Toshimitsu

    2009-12-01

    The tenth Korea-Japan Joint Workshop on Probabilistic Safety Assessment (PSA) was held in the Jeju island of Korea, on May 18-20, 2009 organized by Korea Atomic Energy Research Institute (KAERI). The purpose of the workshop was to provide a forum for presentation and discussions on experiences and technical achievements related to PSA, risk-informed and performance-based approach, and other relevant issues in both countries. Since the first Korea-Japan Joint Workshop on PSA started in 1992, the workshops have provided an important and timely opportunity for exchange and discussion of the relevant information to all PSA practitioners and users of risk information in the industry, research, academia and regulatory arena. This was the tenth anniversary of the Joint Workshop with the main theme of 'For Asian PSA Network' and participants included those from China, Taiwan and the United States of America besides Korea and Japan. Two keynote speeches were presented by the former chairmen of this workshop, Prof. Chang-Sun Kang of Seoul National University and Prof. emeritus Shunsuke Kondo of Tokyo University. We had two special lectures, 70 papers presented by experts at 10 technical sessions related PSA, the special session on the status of PSA in Korea, Japan, China and Taiwan and panel discussion on their cooperation in PSA. This report provides the summary of each session, and all the presentation materials presented in the 10th Korea-Japan Joint Workshop on PSA. (author)

  4. A method for using expert judgement in PSA

    International Nuclear Information System (INIS)

    Pulkkinen, U.; Holmberg, J.

    1997-03-01

    The report discusses an expert judgement methodology development for applications at all levels of probabilistic safety assessment (PSA). The main applications are expected to be at PSA-levels 1 and 2. The method consists of several phases, including the selection and training of the experts, elicitation of experts' judgements, probabilistic modeling and combination of experts' judgements and documentation of the judgement process. The expert training and elicitation process is rather similar to that applied in the NUREG-1150 study. The combination of experts judgements is based on a Bayesian framework utilizing hierarchic models. The posterior distributions of the variables under analysis can be interpreted as a Bayesian counterpart of the combined or aggregated (consensus) distributions, and they are determined by applying Markov chain Monte-Carlo methods. The properties of the method are illustrated by some simple examples. The method is tested in a case study belonging to the benchmark exercise on the use of expert judgement in level 2 PSA, organized as a concerted action of European Commission Fourth Framework Programme on Nuclear Fission Safety. (14 refs.)

  5. Total and ionized serum magnesium and calcium levels during magnesium sulfate administration for preterm labor

    Science.gov (United States)

    Kim, Won Hee; An, Yuna; Moon, Jong Ho; Noh, Eun Ji; Kim, Jong Woon

    2018-01-01

    Objective This study aimed to estimate the association between total and ionized magnesium, and the changes in serum magnesium and calcium levels in patients with preterm labor during magnesium sulfate (MgSO4) administration. Methods The study population included 64 women who were candidates for intravenous MgSO4 treatment for preterm labor. Serial blood samples were taken and measured total magnesium (T-Mg), ionized magnesium (I-Mg), total calcium (T-Ca), and ionized calcium (I-Ca) levels every one-week interval (1st, 2nd, 3rd). Results There was no significant difference in T-Mg and I-Mg levels during MgSO4 administration (P>0.05). There was no significant difference in T-Ca and I-Ca levels during MgSO4 administration (P>0.05). Compared before and after administration of MgSO4, T-Mg and I-Mg levels and T-Ca levels were changed allow statistically significant (P0.05). There was significant correlation between levels of I-Mg and T-Mg (I-Mg=0.395×T-Mg+0.144, P<0.01). Conclusion There were no significant differences in serum Mg and Ca levels during MgSO4 administration for preterm labor. Compared to the before and after administration of MgSO4, only I-Ca levels were not substantially changed. There are significant correlations between I-Mg and T-Mg levels during administration of MgSO4 and I-Mg level seemed to have more correlation with adverse effect than T-Mg. PMID:29372150

  6. Effect of elevated total CoA levels on metabolic pathways in cultured hepatocytes

    International Nuclear Information System (INIS)

    Steffen, C.A.; Smith, C.M.

    1987-01-01

    Livers from fasted rats have 30% higher total CoA levels than fed rats. To determine whether this increase of total CoA influences metabolism, the rates of gluconeogenesis, fatty acid oxidation and ketogenesis were measured in hepatocytes with cyanamide (CYM) or pantothenate (PA) deficient medium used to vary total CoA levels independently of hormonal status. Primary cultures of rat hepatocytes were incubated 14 hrs with Bt 2 cAMP, dexamethasone + theophylline in PA deficient medium or with CYM (500 μM) + PA, rinsed and preincubated 0.5 hr to remove the CYM. Hepatocytes treated with CYM had total CoA levels 10-24% higher than PA deficient cells and lower rates of glucose production from lactate + pyruvate (L/P) or from alanine (0.23 +/- 0.05 and 0.089 +/- 0.02 μm/mg protein, respectively in CYM treated cells compared to 0.33 +/- 0.06 and 0.130 +/- 0.006 in PA deficient cells). This decrease was not due to CYM per se, as the direct addition of CYM stimulated glucose production from L/P. CYM treated cells with 15-40% higher total CoA and 30% higher fatty acyl-CoA levels had the same rates of [ 14 C]-palmitate oxidation as PA deficient cells. However, rates of ketogenesis were lower in CYM treated cells (163 +/- 11 nm/mg compared to 217 +/- 14 nm/mg protein). These results suggest that physiological alterations of hepatic total CoA levels are not necessary for fasting rates of gluconeogenesis, fatty acid oxidation and ketogenesis

  7. Living PSA program for VVER 440/213 in the Czech Republic

    International Nuclear Information System (INIS)

    Husak, S.; Patrik, M.

    2000-01-01

    The paper presents an overview of a Living PSA concept in the Czech Republic for the VVER 440/213 NPP Dukovany unit. The first step of PSA program was a Level 1 basic study for Unit No. 1 which was completed in 1995. The main objective of the study was to determine the risk level of full power operation and its contributors as well as to reveal the weak points of the plant. Living PSA program for a Level 1 study has been afterwards established as a framework for all activities related to risk assessment and risk based decision-making support in NPP Dukovany. The basic parts of the project are: a management of PSA models and studies to implement design and procedures, modifications or new data inputs from data collection; continuous improvement based of new analyses, experiments or more detailed models; an extensions of the scope (external events, all plant operating modes, other sources of radioactive releases). The Living PSA program in NPP Dukovany provides basis for three kinds of PSA activities: risk assessment applications, risk monitoring and risk assessment of operational. (author)

  8. State of the art of probabilistic safety analysis (PSA) in the FRG, and principles of a PSA-guideline

    International Nuclear Information System (INIS)

    Balfanz, H.P.

    1987-01-01

    Contents of the articles: Survey of PSA performed during licensing procedures of an NPP; German Nuclear Standards' requirements on the reliability of safety systems; PSA-guideline for NPP: Principles and suggestions; Motivation and tasks of PSA; Aspects of the methodology of safety analyses; Structure of event tree and fault tree analyses; Extent of safety analyses; Performance and limits of PSA. (orig./HSCH)

  9. Evolution of extreme Total Water Levels along the northern coast of the Iberian Peninsula

    Directory of Open Access Journals (Sweden)

    D. F. Rasilla Álvarez

    2011-02-01

    Full Text Available This paper assesses the evolution of storminess along the northern coast of the Iberian Peninsula through the calculation of extreme (1% Total Water Levels (eTWL on both observed (tide gauge and buoy data and hindcasted (SIMAR-44 data. Those events were first identified and then characterized in terms of oceanographic parameters and atmospheric circulation features. Additionally, an analysis of the long-term trends in both types of data was performed. Most of the events correspond to a rough wave climate and moderate storm surges, linked to extratropical disturbances following a northern track. While local atmospheric conditions seem to be evolving towards lesser storminess, their impact has been balanced by the favorable exposure of the northern coast of the Iberian Peninsula to the increasing frequency and strength of distant disturbances crossing the North Atlantic. This evolution is also correctly reproduced by the simulated long-term evolution of the forcing component (meteorological sea level residuals and wave run up of the Total Water Level values calculated from the SIMAR 44 database, since sea level residuals have been experiencing a reduction while waves are arriving with longer periods. Finally, the addition of the rate of relative sea level trend to the temporal evolution of the atmospheric forcing component of the Total Water Level values is enough to simulate more frequent and persistent eTWL.

  10. Development of multipurpose regulatory PSA model

    International Nuclear Information System (INIS)

    Lee, Chang Ju; Sung, Key Yong; Kim, Hho Jung; Yang, Joon Eon; Ha, Jae Joo

    2004-01-01

    Generally, risk information for nuclear facilities comes from the results of Probabilistic safety assessment (PSA). PSA is a systematic tool to ensure the safety of nuclear facilities, since it is based on thorough and consistent application of probability models. In particular, the PSA has been widely utilized for risk-informed regulation (RIR), including various licensee-initiated risk-informed applications (RIA). In any regulatory decision, the main goal is to make a sound safety decision based on technically defensible information. Also, due to the increased public requests for giving a safety guarantee, the regulator should provide the visible means of safety. The use of PSA by the regulator can give the answer on this problem. Therefore, in order to study the applicability of risk information for regulatory safety management, it is a demanding task to prepare a well-established regulatory PSA model and tool. In 2002, KINS and KAERI together made a research cooperation to form a working group to develop the regulatory PSA model - so-called MPAS model. The MPAS stands for multipurpose probabilistic analysis of safety. For instance, a role of the MPAS model is to give some risk insights in the preparation of various regulatory programs. Another role of this model is to provide an independent risk information to the regulator during regulatory decision-making, not depending on the licensee's information

  11. Development of seismic PSA methodology at JAERI

    International Nuclear Information System (INIS)

    Muramatsu, K.; Ebisawa, K.; Matsumoto, K.; Oikawa, T.; Kondo, M.

    1995-01-01

    The Japan Atomic Energy Research Institute (JAERI) is developing a methodology for seismic probabilistic safety assessment (PSA) of nuclear power plants, aiming at providing a set of procedures, computer codes and data suitable for performing seismic PSA in Japan. In order to demonstrate the usefulness of JAERI's methodology and to obtain better understanding on the controlling factors of the results of seismic PSAs, a seismic PSA for a BWR is in progress. In the course of this PSA, various improvements were made on the methodology. In the area of the hazard analysis, the application of the current method to the model plant site is being carried out. In the area of response analysis, the response factor method was modified to consider the non-linear response effect of the building. As for the capacity evaluation of components, since capacity data for PSA in Japan are very scarce, capacities of selected components used in Japan were evaluated. In the systems analysis, the improvement of the SECOM2 code was made to perform importance analysis and sensitivity analysis for the effect of correlation of responses and correlation of capacities. This paper summarizes the recent progress of the seismic PSA research at JAERI with emphasis on the evaluation of component capacity and the methodology improvement of systems reliability analysis. (author)

  12. Lesson learned from PSA in the design improvement program of KSNP+

    International Nuclear Information System (INIS)

    Kim, M.R.; Lim, H.K.; Kang, S.K.; Park, K.S.

    2001-01-01

    KOPEC (Korea Power Engineering Co.) in conjunction with the client KEPCO (Korea Electric Power Corp.) has been developing a highly competitive Improved Korean Standard Nuclear Power Plant named KSNP+. From the beginning of Design Improvement Program, PSA was carried out to assure that the safety level of KSNP+ is maintained or improved in comparison with that of KSNP, the Korean Standard NPP. To achieve the safety goal of KSNP+, PSA team reviewed all design changes that might affect the plant safety. Design vulnerabilities were identified from the PSA results and safety improvement items were recommended to the system designers. Through the Design Improvement Program, KSNP+ became more reliable, safer and economically competitive than KSNP. This was achieved by systematic approach for design optimization and effective use of PSA technology based on past experience and expertise of nuclear power plant. (author)

  13. Assessing adrenal insufficiency of corticosteroid secretion using free versus total cortisol levels in critical illness

    NARCIS (Netherlands)

    Molenaar, N.; Groeneveld, A.B.J.; Dijstelbloem, H.M.; de Jong, M.F.C.; Girbes, A.R.J.; Heijboer, A.C.; Beishuizen, A.

    2011-01-01

    Purpose: To study the value of free versus total cortisol levels in assessing relative adrenal insufficiency during critical illness-related corticosteroid insufficiency. Methods: A prospective study in a mixed intensive care unit from 2004 to 2007. We consecutively included 49 septic and 63

  14. Assessing adrenal insufficiency of corticosteroid secretion using free versus total cortisol levels in critical illness

    NARCIS (Netherlands)

    Molenaar, Nienke; Johan Groeneveld, A. B.; Dijstelbloem, Hilde M.; de Jong, Margriet F. C.; Girbes, Armand R. J.; Heijboer, Annemieke C.; Beishuizen, Albertus

    2011-01-01

    To study the value of free versus total cortisol levels in assessing relative adrenal insufficiency during critical illness-related corticosteroid insufficiency. A prospective study in a mixed intensive care unit from 2004 to 2007. We consecutively included 49 septic and 63 non-septic patients with

  15. PSA use in accident management studies in Japan

    International Nuclear Information System (INIS)

    Hirano, Mitsumasa

    1994-01-01

    The safety of NPPs in Japan is secured by stringent safety regulations based on the deterministic method, minimizing the possibility a severe accident to a technologically negligible level. PSA is not required in the current regulatory procedures. Accident management based on PSA is a 'knowledge-based' action dependent on utilities' technical knowledge aimed at further reduction of the risk which is kept small enough by existing measures. The paper discusses the following three kinds of PSAs that have been conducted practically and efficiently on NPPs to provide supplemental information about their safety characteristics in addition to the deterministic evaluation used in the regulatory safety review: PSAs on typical NPPs, PSAs on all NPPs to examine candidates for accident management, and PSAs as part of periodic safety review (PSR). 1 fig., 5 tabs

  16. Upgrade of Common Cause Failure Modelling of NPP Krsko PSA

    International Nuclear Information System (INIS)

    Vukovic, I.; Mikulicic, V.; Vrbanic, I.

    2006-01-01

    -16187 and this too was considered. Similarly to the argument related to methodological aspects, it is desirable that NEK CCF parameters are in general accordance with recommended set of WOG parameters. The paper considers the approach undertaken on upgrade of common cause failure modelling in NPP Krsko PSA Level 1 model and discusses the results and lessons learned from this complex project. (author)

  17. Effects of buddleja officinalis total flavonoids on serum testosterone level of castrated male rats with xeroma

    Directory of Open Access Journals (Sweden)

    Wen-Juan Li

    2013-11-01

    Full Text Available AIM:To observe buddleja officinalis total flavonoids' effect on the basal tear secretion amount, tear film stability, lacrimal gland histomorphology and serum testosterone level of castrated male rat model with xeroma, to study the mechanism of rat xeroma caused by buddleja officinalis total flavones' anti-sex hormones disorders.MEATHODS: A total of 150 Wistar male rats of 1 month old, weighted about 200g, were randomly divided into 5 groups with 30 rats in each group with A representing normal group; B representing sham operation group; C representing surgery control group; D representing group treated with androgen; E representing group treated with buddleja officinalis total flavonoids. For the groups C, D, E, the bilateral testicle and epididymis were excised; For group B, scrota were incised without removal of the testicles, as the sham operation group; For group A, nothing was done. One week after modeling when the wound was to be healed, drug was given to each group. Respectively at the 1st month, 3rd, and 5th months after treatment, 10 rats were randomly selected in each group, to receive Schirmer I test, tear breakup time measurement. Blood serum testosterone levels were tested in the fifth month. RESUITS: For groups D and E, the Schirmer I test measurements were significantly higher than that of group C(PPPCONCLUSION: Decreased androgen levels can lead to xeroma, and removal of bilateral testes and epididymis can successfully establish the animal models of xeroma in rats caused by decreased androgen levels. Buddleja officinalis total flavonoids have androgenic effect, which produces the similar treatment effect of xeroma with testosterone propionate. Buddleja officinalis total flavonoids may become a new treatment for xeroma.

  18. Total circulating microparticle levels are increased in patients with deep infiltrating endometriosis.

    Science.gov (United States)

    Munrós, J; Martínez-Zamora, M A; Tàssies, D; Coloma, J L; Torrente, M A; Reverter, J C; Carmona, F; Balasch, J

    2017-02-01

    Are the levels of total circulating cell-derived microparticles (cMPs) and circulating tissue factor-containing microparticles (cMP-TF) increased in patients with endometriosis? The levels of total cMP, but not cMP-TF, were higher in patients with endometriosis, and these were attributed to higher levels in patients with deep infiltrating endometriosis (DIE). Previous studies have reported elevated levels of total cMP in inflammatory conditions as well as higher levels of other inflammatory biomarkers in endometriosis. Increased expression of tissue factor (a transmembrane receptor for Factor VII/VIIa) in eutopic and ectopic endometrium from patients with endometriosis has been described. There is no previous data regarding total cMP and cMP-TF levels in patients with endometriosis. A prospective case-control study including two groups of patients was carried out. The E group included 65 patients with surgically confirmed endometriosis (37 with DIE lesions) and the C group comprises 33 women without surgical findings of any form of endometriosis. Patients and controls were recruited during the same 10-month period. Controls were the next patient without endometriosis undergoing surgery, after including two patients with endometriosis. Venous blood samples for total cMP and cMP-TF determinations were obtained at the time of surgery, before anesthesia at a tertiary care center. To assess total cMP, an ELISA functional assay was used and cMP-TF activity in plasma was measured using an ELISA kit. Total cMP levels in plasma were higher in the E group compared with the C group (P < 0.0001). The subanalysis of endometriosis patients with DIE or with ovarian endometriomas without DIE showed that total cMP levels were higher in the DIE group (P = 0.001). There were no statistically significant differences in cMP-TF levels among the groups analyzed. This is a preliminary study in which the sample size was arbitrarily decided, albeit in keeping with previous studies analyzing

  19. Total mercury, cadmium and lead levels in main export fish of Sri Lanka.

    Science.gov (United States)

    Jinadasa, B K K K; Edirisinghe, E M R K B; Wickramasinghe, I

    2014-01-01

    Total mercury (Hg), cadmium (Cd) and lead (Pb) levels were determined in the muscle of four commercialised exported fish species Thunnus albacares (yellowfin tuna), Xiphias gladius (swordfish), Makaira indica (black marlin) and Lutjanus sp (red snapper) collected from the Indian Ocean, Sri Lanka, during July 2009-March 2010 and measured by atomic absorption spectrophotometry. Results show that swordfish (n = 176) contained the highest total Hg (0.90 ± 0.51 mg/kg) and Cd (0.09 ± 0.13 mg/kg) levels, whereas yellowfin tuna (n = 140) contained the highest Pb levels (0.11 ± 0.16 mg/kg). The lowest total Hg (0.16 ± 0.11 mg/kg), Cd (0.01 ± 0.01 mg/kg) and Pb (0.04 ± 0.04 mg/kg) levels were found in red snapper (n = 28). Black marlin (n = 24) contained moderate levels of total Hg (0.49 ± 0.37), Cd (0.02 ± 0.02) and Pb (0.05 ± 0.05). Even though there are some concerns during certain months of the year, this study demonstrates the safety of main export fish varieties in terms of total Hg, Cd and Pb.

  20. Hypogonadism and subnormal total testosterone levels in men with type 2 diabetes mellitus

    International Nuclear Information System (INIS)

    Ogbera, O.A.; Sonny, C.; Olufemi, F.; Wale, A.

    2011-01-01

    Objective: To determine the frequency of testosterone deficiency syndrome (TDS) in men with type 2 diabetes mellitus (DM). Study Design: A cross-sectional study. Place and Duration of Study: The Gbagada General Hospital, Gbagada Lagos, Nigeria, from December 2009 to May 2010. Methodology: A total of 203 men with type 2 DM aged 30-86 years were evaluated for TDS by a combination of positive ADAM (androgen deficiency in the ageing male) scores and subnormal total testosterone levels. Mild testosterone deficiency referred to total testosterone (TT) levels of 8-12 nmol/L with symptoms of hypogonadism and severe testosterone deficiency referred to TT levels < 8 nmol/L with or without hypogonadal symptoms. Results: Mild and severe TDS were present in 18.3% and 17% respectively of the study subjects. Commonly occurring clinical parameters of the TDS were erectile dysfunction and loss of libido, which were documented in 63% and 60% respectively in the study subjects. The majority of clinical features of the TDS were comparable in men with and without the TDS. Conclusion: About a third of men with type 2 DM had the TDS. The majority of the symptoms of hypogonadism are largely non-specific and their occurrence is comparable in men with and without low testosterone levels; thus, underscoring the need to have testosterone levels determined in men presenting with such symptoms. (author)