WorldWideScience

Sample records for total primary energy

  1. Determining the primary cosmic ray energy from the total flux of Cherenkov light measured at the Yakutsk EAS array

    International Nuclear Information System (INIS)

    Ivanov, A. A.; Knurenko, S. P.; Sleptsov, I. E.

    2007-01-01

    We present a method for determining the energy of the primary particle that generates an extensive air shower (EAS) of comic rays based on measuring the total flux of Cherenkov light from the shower. Applying this method to Cherenkov light measurements at the Yakutsk EAS array has allowed us to construct the cosmic ray energy spectrum in the range 10 15 - 3 x 10 19 eV

  2. 2005 primary energy consumption in Germany

    International Nuclear Information System (INIS)

    Anon.

    2006-01-01

    According to preliminar calculations by the Arbeitsgemeinschaft Energiebilanzen (Working Party on Energy Balances, AGEB), the consumption of an aggregate 486 million TCE of primary energy resources in Germany last year was 1.3% below the level of the year before. Energy consumption was influenced by both the high level of prices and the development of the economy. Hardly any influence was attributable to the level of temperatures, which was largely unchanged compared to the figure of the year before. Oil consumption in 2005 in Germany dropped by nearly 2% to 174.8 million TCE. On the whole, oil with its 36% share in the energy balance remained by far the most important energy resource in Germany. Natural gas consumption of 110.4 million TCE was at the level of the year before. Its share in the primary energy balance rose slightly to 22.7%. Hard coal, because of lower use in power plants and the decline in iron making, showed a 4.6% drop in consumption to 62.8 million TCE. In this way, hard coal contributed 13% to total energy consumption. Lignite consumption dropped by 3.2% to 54.4 million TCE as a result of lower deliveries to power plants. Its 11.2% share in the total consumption of primary energy continued to make lignite the most important domestic energy resource. More than 90% of the lignite produced is used for electricity generation. The contribution to primary energy consumption of nuclear power dropped by more than 2% to 60.7 million TCE. Hydroelectric plants and wind power plants increased their contribution by 3.6%. The contribution to primary energy consumption made by all renewable energy resources rose to 4.6%. AGEB evaluates statistics of all areas of the power economy on the basis of standard criteria in order to combine these data in a comprehensive picture. Since 1994, the energy balances for Germany have been compiled by DIW on behalf of AGEB. (orig.)

  3. Life cycle primary energy analysis of residential buildings

    Energy Technology Data Exchange (ETDEWEB)

    Gustavsson, Leif; Joelsson, Anna [Ecotechnology, Department of Engineering and Sustainable Development, Mid Sweden University, SE-831 25 Oestersund (Sweden)

    2010-02-15

    The space heating demand of residential buildings can be decreased by improved insulation, reduced air leakage and by heat recovery from ventilation air. However, these measures result in an increased use of materials. As the energy for building operation decreases, the relative importance of the energy used in the production phase increases and influences optimization aimed at minimizing the life cycle energy use. The life cycle primary energy use of buildings also depends on the energy supply systems. In this work we analyse primary energy use and CO{sub 2} emission for the production and operation of conventional and low-energy residential buildings. Different types of energy supply systems are included in the analysis. We show that for a conventional and a low-energy building the primary energy use for production can be up to 45% and 60%, respectively, of the total, depending on the energy supply system, and with larger variations for conventional buildings. The primary energy used and the CO{sub 2} emission resulting from production are lower for wood-framed constructions than for concrete-framed constructions. The primary energy use and the CO{sub 2} emission depend strongly on the energy supply, for both conventional and low-energy buildings. For example, a single-family house from the 1970s heated with biomass-based district heating with cogeneration has 70% lower operational primary energy use than if heated with fuel-based electricity. The specific primary energy use with district heating was 40% lower than that of an electrically heated passive row house. (author)

  4. Primary energy implications of different design strategies for an apartment building

    International Nuclear Information System (INIS)

    Tettey, Uniben Yao Ayikoe; Dodoo, Ambrose; Gustavsson, Leif

    2016-01-01

    In this study, we explored the effects of different design strategies on final and primary energy use for production and operation of a newly constructed apartment building. We analysed alternatives of the building “As built” as well as to energy efficiency levels of the Swedish building code and passive house criteria. Our approach is based on achieving improved versions of the building alternatives from combination of design strategies giving the lowest space heating and cooling demand and primary energy use, respectively. We found that the combination of design strategies resulting in the improved building alternatives varies depending on the approach. The improved building alternatives gave up to 19–34% reduction in operation primary energy use compared to the initial alternatives. The share of production primary energy use of the improved building alternatives was 39–54% of the total primary energy use for production, space heating, space cooling and ventilation over 50-year lifespan, compared to 31–42% for the initial alternatives. This study emphasises the importance of incorporating appropriate design strategies to reduce primary energy use for building operation and suggests that combining such strategies with careful choice of building frame materials could result in significant primary energy savings in the built environment. - Highlights: • Primary energy implications of different design strategies were analysed. • The improved building alternatives had 19–34% lower operation primary energy use. • The improved building alternatives had higher production primary energy use. • Still, the improved building alternatives had lower overall primary energy use. • Design strategies should be combined with careful building frame material choice.

  5. Comparing primary energy attributed to renewable energy with primary energy equivalent to determine carbon abatement in a national context.

    Science.gov (United States)

    Gallachóir, Brian P O; O'Leary, Fergal; Bazilian, Morgan; Howley, Martin; McKeogh, Eamon J

    2006-01-01

    The current conventional approach to determining the primary energy associated with non-combustible renewable energy (RE) sources such as wind energy and hydro power is to equate the electricity generated from these sources with the primary energy supply. This paper compares this with an approach that was formerly used by the IEA, in which the primary energy equivalent attributed to renewable energy was equated with the fossil fuel energy it displaces. Difficulties with implementing this approach in a meaningful way for international comparisons lead to most international organisations abandoning the primary energy equivalent methodology. It has recently re-emerged in prominence however, as efforts grow to develop baseline procedures for quantifying the greenhouse gas (GHG) emissions avoided by renewable energy within the context of the Kyoto Protocol credit trading mechanisms. This paper discusses the primary energy equivalent approach and in particular the distinctions between displacing fossil fuel energy in existing plant or in new plant. The approach is then extended provide insight into future primary energy displacement by renewable energy and to quantify the amount of CO2 emissions avoided by renewable energy. The usefulness of this approach in quantifying the benefits of renewable energy is also discussed in an energy policy context, with regard to increasing security of energy supply as well as reducing energy-related GHG (and other) emissions. The approach is applied in a national context and Ireland is case study country selected for this research. The choice of Ireland is interesting in two respects. The first relates to the high proportion of electricity only fossil fuel plants in Ireland resulting in a significant variation between primary energy and primary energy equivalent. The second concerns Ireland's poor performance to date in limiting GHG emissions in line with its Kyoto target and points to the need for techniques to quantify the potential

  6. Classification and performance analysis of primary energy consumers during 1980-1999

    International Nuclear Information System (INIS)

    Ediger, Volkan S.

    2003-01-01

    Five primary energy consumer classes, namely Super, Major, Big, Medium and Small, are proposed, depending on the polymodal characteristics of the frequency distribution curve of their share of the total. The total primary energy consumption and its annual additions decrease, whereas the rates increase steadily from the Super to the Medium consumers. Since the frequency distribution histogram of additional primary energy consumptions of the Medium and above consumers during 1980-1999 is a typical bell shaped curve, the additional amounts and rates are used together to evaluate the performance levels of the countries in both parameters. The most successful countries are the USA, China, South Korea, Thailand, India, Indonesia, Taiwan, Turkey and Iran. The reason why the Super consumer USA and the Major consumer China are the biggest energy markets is because they are the first two biggest economies in the world. The success of the developing Asian countries is mostly related to their economic ties with the Super consumer USA. Among the other emerging markets, Turkey's primary energy demand has grown more rapidly than that of Iran and is expected to continue growing in the future. The emerging Medium and Big consumer markets will continue to play a significant role in the world's energy sector during the first two decades of the 21st century

  7. Primary energy and greenhouse gas implications of increasing biomass production through forest fertilization

    Energy Technology Data Exchange (ETDEWEB)

    Sathre, Roger [Ecotechnology, Mid Sweden University, Ostersund (Sweden); Gustavsson, Leif [Ecotechnology, Mid Sweden University, Ostersund (Sweden); Bergh, Johan [Ecotechnology, Mid Sweden University, Ostersund (Sweden); Southern Swedish Forest Research Centre, Swedish University of Agricultural Sciences, Alnarp (Sweden)

    2010-04-15

    In this study we analyze the primary energy and greenhouse gas (GHG) implications of increasing biomass production by fertilizing 10% of Swedish forest land. We estimate the primary energy use and GHG emissions from forest management including production and application of N and NPK fertilizers. Based on modelled growth response, we then estimate the net primary energy and GHG benefits of using biomaterials and biofuels obtained from the increased forest biomass production. The results show an increased annual biomass harvest of 7.4 million t dry matter, of which 41% is large-diameter stemwood. About 6.9 PJ/year of additional primary energy input is needed for fertilizer production and forest management. Using the additional biomass for fuel and material substitution can reduce fossil primary energy use by 150 or 164 PJ/year if the reference fossil fuel is fossil gas or coal, respectively. About 22% of the reduced fossil energy use is due to material substitution and the remainder is due to fuel substitution. The net annual primary energy benefit corresponds to about 7% of Sweden's total primary energy use. The resulting annual net GHG emission reduction is 11.9 million or 18.1 million tCO{sub 2equiv} if the reference fossil fuel is fossil gas or coal, respectively, corresponding to 18% or 28% of the total Swedish GHG emissions in 2007. A significant one-time carbon stock increase also occurs in wood products and forest tree biomass. These results suggest that forest fertilization is an attractive option for increasing energy security and reducing net GHG emission.

  8. Primary energy and greenhouse gas implications of increasing biomass production through forest fertilization

    International Nuclear Information System (INIS)

    Sathre, Roger; Gustavsson, Leif; Bergh, Johan

    2010-01-01

    In this study we analyze the primary energy and greenhouse gas (GHG) implications of increasing biomass production by fertilizing 10% of Swedish forest land. We estimate the primary energy use and GHG emissions from forest management including production and application of N and NPK fertilizers. Based on modelled growth response, we then estimate the net primary energy and GHG benefits of using biomaterials and biofuels obtained from the increased forest biomass production. The results show an increased annual biomass harvest of 7.4 million t dry matter, of which 41% is large-diameter stemwood. About 6.9 PJ/year of additional primary energy input is needed for fertilizer production and forest management. Using the additional biomass for fuel and material substitution can reduce fossil primary energy use by 150 or 164 PJ/year if the reference fossil fuel is fossil gas or coal, respectively. About 22% of the reduced fossil energy use is due to material substitution and the remainder is due to fuel substitution. The net annual primary energy benefit corresponds to about 7% of Sweden's total primary energy use. The resulting annual net GHG emission reduction is 11.9 million or 18.1 million tCO 2equiv if the reference fossil fuel is fossil gas or coal, respectively, corresponding to 18% or 28% of the total Swedish GHG emissions in 2007. A significant one-time carbon stock increase also occurs in wood products and forest tree biomass. These results suggest that forest fertilization is an attractive option for increasing energy security and reducing net GHG emission.

  9. Primary energy and greenhouse gas implications of increasing biomass production through forest fertilization

    Energy Technology Data Exchange (ETDEWEB)

    Sathre, Roger; Gustavsson, Leif [Ecotechnology, Mid Sweden University, Oestersund (Sweden); Bergh, Johan [Ecotechnology, Mid Sweden University, Oestersund (Sweden); Southern Swedish Forest Research Centre, Swedish University of Agricultural Sciences, Alnarp (Sweden)

    2010-04-15

    In this study we analyze the primary energy and greenhouse gas (GHG) implications of increasing biomass production by fertilizing 10% of Swedish forest land. We estimate the primary energy use and GHG emissions from forest management including production and application of N and NPK fertilizers. Based on modelled growth response, we then estimate the net primary energy and GHG benefits of using biomaterials and biofuels obtained from the increased forest biomass production. The results show an increased annual biomass harvest of 7.4 million t dry matter, of which 41% is large-diameter stemwood. About 6.9 PJ/year of additional primary energy input is needed for fertilizer production and forest management. Using the additional biomass for fuel and material substitution can reduce fossil primary energy use by 150 or 164 PJ/year if the reference fossil fuel is fossil gas or coal, respectively. About 22% of the reduced fossil energy use is due to material substitution and the remainder is due to fuel substitution. The net annual primary energy benefit corresponds to about 7% of Sweden's total primary energy use. The resulting annual net GHG emission reduction is 11.9 million or 18.1 million tCO{sub 2equiv} if the reference fossil fuel is fossil gas or coal, respectively, corresponding to 18% or 28% of the total Swedish GHG emissions in 2007. A significant one-time carbon stock increase also occurs in wood products and forest tree biomass. These results suggest that forest fertilization is an attractive option for increasing energy security and reducing net GHG emission. (author)

  10. Doctor Referral of Overweight People to a Low-Energy Treatment (DROPLET) in primary care using total diet replacement products: a protocol for a randomised controlled trial.

    Science.gov (United States)

    Jebb, Susan A; Astbury, Nerys M; Tearne, Sarah; Nickless, Alecia; Aveyard, Paul

    2017-08-04

    The global prevalence of obesity has risen significantly in recent decades. There is a pressing need to identify effective interventions to treat established obesity that can be delivered at scale. The aim of the Doctor Referral of Overweight People to a Low-Energy Treatment (DROPLET) study is to determine the clinical effectiveness, feasibility and acceptability of referral to a low-energy total diet replacement programme compared with usual weight management interventions in primary care. The DROPLET trial is a randomised controlled trial comparing a low-energy total diet replacement programme with usual weight management interventions delivered in primary care. Eligible patients will be recruited through primary care registers and randomised to receive a behavioural support programme delivered by their practice nurse or a referral to a commercial provider offering an initial 810 kcal/d low-energy total diet replacement programme for 8 weeks, followed by gradual food reintroduction, along with weekly behavioural support for 24 weeks. The primary outcome is weight change at 12 months. The secondary outcomes are weight change at 3 and 6 months, the proportion of participants achieving 5% and 10% weight loss at 12 months, and change in fat mass, haemoglobin A1c, low-density lipoprotein cholesterol and systolic and diastolic blood pressure at 12 months. Data will be analysed on the basis of intention to treat. Qualitative interviews on a subsample of patients and healthcare providers will assess their experiences of the weight loss programmes and identify factors affecting acceptability and adherence. This study has been reviewed and approved by the National Health ServiceHealth Research Authority (HRA)Research Ethics Committee (Ref: SC/15/0337). The trial findings will be disseminated to academic and health professionals through presentations at meetings and peer-reviewed journals and to the public through the media. If the intervention is effective, the results

  11. Primary Energy of the District city and Suburb

    Science.gov (United States)

    Pitonak, Anton; Lopusniak, Martin; Bagona, Miloslav

    2017-10-01

    In member states of the European Union, portion of buildings in the total consumption of energy represents 40 %, and their share in CO2 emissions represents 35 %. Taking into account the dependence of the European Union on import of energy, this represents a large quantity of energy and CO2 in spite of the fact that effective solutions for the reduction of energy demand of buildings exist. The European Union adopted three main commitments for fulfilment of criteria by year 2020 in the 20-20-20 Directive. Based on this Directive Slovakia declares support for renovating the building stock. The goal of the paper was to prove that renovation of the building stock is environmentally and energy preferably as construction of new buildings. In the paper, the settlement unit with the suburban one were compared. Both territories are dealt with in Kosice city, in Slovakia. The settlement units include apartment dwelling houses, amenities, parking areas and green. Suburban part contains family houses. The decisive factor for the final assessment of the buildings was global indicator. Global indicator of the energy performance is primary energy. The new building must meet minimum requirements for energy performance and it must be classified to energy class A1 since 2016, and to energy class A0 since 2020. The paper analyses the effects of the use of different resources of heat considering the global indicator. Primary energy was calculated and based on comparable unit. The primary energy was accounted for on the built-up area, area corresponding to district city and suburb, number of inhabitants. The study shows that the lowest values of global indicator are achieved by using wood. The highest values of global indicator are achieved by using electricity or district heating as an energy source. The difference between the highest and lowest value is 87 %. Primary energy based on inhabitant is 98 % lower in settlement unit compared to the suburban one.

  12. A prospective study of spine fractures diagnosed by total spine computed tomography in high energy trauma patients

    International Nuclear Information System (INIS)

    Takami, Masanari; Nohda, Kazuhiro; Sakanaka, Junya; Nakamura, Masamichi; Yoshida, Munehito

    2011-01-01

    Since it is known to be impossible to identify spinal fractures in high-energy trauma patients the primary trauma evaluation, we have been performing total spine computed tomography (CT) in high-energy trauma cases. We investigated the spinal fractures that it was possible to detect by total spine CT in 179 cases and evaluated the usefulness of total spine CT prospectively. There were 54 (30.2%) spinal fractures among the 179 cases. Six (37.5%) of the 16 cervical spine fractures that were not detected on plain X-ray films were identified by total spine CT. Six (14.0%) of 43 thoracolumbar spine fractures were considered difficult to diagnose based on the clinical findings if total spine CT had not been performed. We therefore concluded that total spine CT is very useful and should be performed during the primary trauma evaluation in high-energy trauma cases. (author)

  13. Conversion total hip arthroplasty: Primary or revision total hip arthroplasty

    Science.gov (United States)

    Schwarzkopf, Ran; Baghoolizadeh, Mahta

    2015-01-01

    Total hip arthroplasty (THA) is an increasingly common procedure among elderly individuals. Although conversion THA is currently bundled in a diagnosis related group (DRG) with primary THA, there is a lack of literature supporting this classification and it has yet to be identified whether conversion THA better resembles primary or revision THA. This editorial analyzed the intraoperative and postoperative factors and functional outcomes following conversion THA, primary THA, and revision THA to understand whether the characteristics of conversion THA resemble one procedure or the other, or are possibly somewhere in between. The analysis revealed that conversion THA requires more resources both intraoperatively and postoperatively than primary THA. Furthermore, patients undergoing conversion THA present with poorer functional outcomes in the long run. Patients undergoing conversion THA better resemble revision THA patients than primary THA patients. As such, patients undergoing conversion THA should not be likened to patients undergoing primary THA when determining risk stratification and reimbursement rates. Conversion THA procedures should be planned accordingly with proper anticipation of the greater needs both in the operating room, and for in-patient and follow-up care. We suggest that conversion THA be reclassified in the same DRG with revision THA as opposed to primary THA as a step towards better allocation of healthcare resources for conversion hip arthroplasties. PMID:26601055

  14. Primary extra-cranial meningioma following total hip replacement

    Energy Technology Data Exchange (ETDEWEB)

    Campbell, T.J.; Beggs, I. [Royal Infirmary, Department of Radiology, Edinburgh (United Kingdom); Patton, J.T.; Porter, D. [Royal Infirmary, Department of Orthopaedics, Edinburgh (United Kingdom); Salter, D.M.; Al-Nafussi, A. [Royal Infirmary, Department of Pathology, Edinburgh (United Kingdom)

    2009-01-15

    A 61-year-old man presented with pain at the left hip and decreased mobility 10 years after total hip replacement. Imaging demonstrated a large destructive expansile mass adjacent to the prosthesis. Histological analysis confirmed the presence of an extra-cranial meningioma. Primary tumours after total hip replacement are rare and include soft tissue sarcomas, bone sarcomas and lymphomas. To our knowledge, no previous cases of primary extracranial meningioma have been identified. The imaging features, histology, pathogenesis and differential diagnosis are discussed. (orig.)

  15. The total energy policy in Flanders

    International Nuclear Information System (INIS)

    Bouma, J.W.J.

    1994-01-01

    The policy of the Flemish region (Belgium) with regard to the total energy principle are presented. An overview of the main policy instruments to support energy saving and environmental-friendly investments as well as the development of new technologies is given. The total energy policy of the Flanders Region forms part of the general Flemish (energy) policy. (A.S.)

  16. Total-factor energy efficiency in developing countries

    International Nuclear Information System (INIS)

    Zhang Xingping; Cheng Xiaomei; Yuan Jiahai; Gao Xiaojun

    2011-01-01

    This paper uses a total-factor framework to investigate energy efficiency in 23 developing countries during the period of 1980-2005. We explore the total-factor energy efficiency and change trends by applying data envelopment analysis (DEA) window, which is capable of measuring efficiency in cross-sectional and time-varying data. The empirical results indicate that Botswana, Mexico and Panama perform the best in terms of energy efficiency, whereas Kenya, Sri Lanka, Syria and the Philippines perform the worst during the entire research period. Seven countries show little change in energy efficiency over time. Eleven countries experienced continuous decreases in energy efficiency. Among five countries witnessing continuous increase in total-factor energy efficiency, China experienced the most rapid rise. Practice in China indicates that effective energy policies play a crucial role in improving energy efficiency. Tobit regression analysis indicates that a U-shaped relationship exists between total-factor energy efficiency and income per capita. - Research Highlights: → To measure the total-factor energy efficiency using DEA window analysis. → Focus on an application area of developing countries in the period of 1980-2005. → A U-shaped relationship was found between total-factor energy efficiency and income.

  17. Total energy calculations from self-energy models

    International Nuclear Information System (INIS)

    Sanchez-Friera, P.

    2001-06-01

    Density-functional theory is a powerful method to calculate total energies of large systems of interacting electrons. The usefulness of this method, however, is limited by the fact that an approximation is required for the exchange-correlation energy. Currently used approximations (LDA and GGA) are not sufficiently accurate in many physical problems, as for instance the study of chemical reactions. It has been shown that exchange-correlation effects can be accurately described via the self-energy operator in the context of many-body perturbation theory. This is, however, a computationally very demanding approach. In this thesis a new scheme for calculating total energies is proposed, which combines elements from many-body perturbation theory and density-functional theory. The exchange-correlation energy functional is built from a simplified model of the self-energy, that nevertheless retains the main features of the exact operator. The model is built in such way that the computational effort is not significantly increased with respect to that required in a typical density-functional theory calculation. (author)

  18. Total energy system in the future

    International Nuclear Information System (INIS)

    Hijikata, K.

    1994-01-01

    The possibility of improving the thermal efficiency of energy systems from an exergy point of view is discussed. In total energy systems, we should employ multi-pass recycling consisting of thermal and chemical energies. The recycling system is supported by electrical energy, which is provided by a renewable energy source or by excess commercial electric power. This total energy system should be considered not only in one country, but all around the globe. (author). 6 figs., 4 tabs., 8 refs

  19. Nuclear primary energy carriers. Short version

    Energy Technology Data Exchange (ETDEWEB)

    Jaeck, W

    1978-04-01

    Basing on our present knowledge the following energy sources for energy supply must be taken into consideration in the long term: regenerative energy sources, fission energy gained by breeder reactors, nuclear fusion. While regenerative energy sources were treated at full length in the study 'Energy Sources for Tomorrow' the present study specifies the other two energy options. The availability and the reliability of nuclear primary energy carrier supply is described in detail and the conversion systems available or still being developed are investigated with regard to their specific consumption of primary energy. Topical questions concerning the proliferation stability of the fuel cycles and techniques are subject to the INFCE program. With reference to the nuclear energy documentation activities of the Federal Government this study is supposed to supply further fundamental material on nuclear primary energy carriers, consumption and readiness for application. Thus it will contribute to the question: 'Is nuclear energy an option which guarantees energy supply in the long term for the Federal Republic of Germany'. (orig.) 891 UA 892 ARA.

  20. Nuclear primary energy carriers. Pt. 1

    International Nuclear Information System (INIS)

    1978-04-01

    Basing on our present knowledge the following energy sources for energy supply must be taken into consideration in the long term: regenerative energy sources, fission energy gained by breeder reactors, nuclear fusion. While regenerative energy sources were treated at full length in the study 'Energy Sources for tomorrow' the present study specifies the other two energy options. The availability and the reliability of nuclear primary energy carrier supply is described in detail and the conversion systems available or still being developed are investigated with regard to their specific consumption of primary energy. Topical questions concerning the proliferation stability of the fuel cycles and techniques are subject to the INFCE programme. With reference to the nuclear energy documentation activities of the Federal Govenment this study is supposed to supply further fundamental material on nuclear primary energy carriers, consumption and readiness for application. Thus it will contribute to the question: 'Is nuclear energy an option which guarantees energy supply in the long term for the Federal Republic of Germany'. (orig.) [de

  1. Application of Total Quality Management System in Thai Primary Schools

    Science.gov (United States)

    Prueangphitchayathon, Setthiya; Tesaputa, Kowat; Somprach, Kanokorn

    2015-01-01

    The present study seeks to develop a total quality management (TQM) system that can be applied to primary schools. The approach focuses on customer orientation, total involvement of all constituencies and continuous improvement. TQM principles were studied and synthesized according to case studies of the best practices in 3 primary schools (small,…

  2. Empirical and dynamic primary energy factors

    International Nuclear Information System (INIS)

    Wilby, Mark Richard; Rodríguez González, Ana Belén; Vinagre Díaz, Juan José

    2014-01-01

    Current legislation, standards, and scientific research in the field of energy efficiency often make use of PEFs (primary energy factors). The measures employed are usually fixed and based on theoretical calculations. However given the intrinsically variable nature of energy systems, these PEFs should rely on empirical data and evolve in time. Otherwise the obtained efficiencies may not be representative of the actual energy system. In addition, incorrect PEFs may cause a negative effect on the energy efficiency measures. For instance, imposing a high value on the PEF of electricity may discourage the use of renewable energy sources, which have an actual value close to 1. In order to provide a solution to this issue, we propose an application of the Energy Networks (ENs), described in a previous work, to calculate dynamic PEFs based on empirical data. An EN represents an entire energy system both numerically and graphically, from its primary energy sources to their final energy forms, and consuming sectors. Using ENs we can calculate the PEF of any energy form and depict it in a simple and meaningful graph that shows the details of the contribution of each primary energy and the efficiency of the associated process. The analysis of these PEFs leads to significant conclusions regarding the energy models adopted among countries, their evolution in time, the selection of viable ways to improve efficiency, and the detection of best practices that could contribute to the overall energy efficiency targets. - Highlights: • Primary Energy Factors (PEFs) are foundation of much energy legislation and research. • Traditionally, they have been treated as geotemporally invariant. • This work provides a systematic and transparent methodology for adding variability. • It also shows the variability between regions due to market, policy, and technology. • Finally it demonstrates the utility of extended PEFs as a tool in their own right

  3. Access to primary energy sources - the basis of national energy security

    Science.gov (United States)

    Szlązak, Jan; Szlązak, Rafał A.

    2017-11-01

    National energy security is of fundamental importance for economic development of a country. To ensure such safety energy raw material, also called primary energy sources, are necessary. Currently in Poland primary energy sources include mainly fossil fuels, such as hard coal, brown coal, natural gas and crude oil. Other sources, e.g. renewable energy sources account for c. 15% in the energy mix. Primary energy sources are used to produce mainly electricity, which is considered as the cleanest form of energy. Poland does not have, unfortunately, sufficient energy sources and is forced to import some of them, mainly natural gas and crude oil. The article presents an insightful analysis of energy raw material reserves possessed by Poland and their structure taking account of the requirements applicable in the European Union, in particular, those related to environmental protection. The article also describes demand for electricity now and in the perspective of 2030. Primary energy sources necessary for its production have also been given. The article also includes the possibilities for the use of renewable energy sources in Poland, however, climatic conditions there are not are not particularly favourable to it. All the issues addressed in the article are summed up and ended with conclusions.

  4. Using Sankey diagrams to map energy flow from primary fuel to end use

    International Nuclear Information System (INIS)

    Subramanyam, Veena; Paramshivan, Deepak; Kumar, Amit; Mondal, Md. Alam Hossain

    2015-01-01

    Highlights: • Energy flows from both supply and demand sides shown through Sankey diagrams. • Energy flows from reserves to energy end uses for primary and secondary fuels shown. • Five main energy demand sectors in Alberta are analyzed. • In residential/commercial sectors, highest energy consumption is in space heating. • In the industrial sector, highest energy use is in the mining subsector. - Abstract: The energy sector is the largest contributor to gross domestic product (GDP), income, employment, and government revenue in both developing and developed nations. But the energy sector has a significant environmental footprint due to greenhouse gas (GHG) emissions. Efficient production, conversion, and use of energy resources are key factors for reducing the environmental footprint. Hence it is necessary to understand energy flows from both the supply and the demand sides. Most energy analyses focus on improving energy efficiency broadly without considering the aggregate energy flow. We developed Sankey diagrams that map energy flow for both the demand and supply sides for the province of Alberta, Canada. The diagrams will help policy/decision makers, researchers, and others to understand energy flow from reserves through to final energy end uses for primary and secondary fuels in the five main energy demand sectors in Alberta: residential, commercial, industrial, agricultural, and transportation. The Sankey diagrams created for this study show total energy consumption, useful energy, and energy intensities of various end-use devices. The Long-range Energy Alternatives Planning System (LEAP) model is used in this study. The model showed that Alberta’s total input energy in the five demand sectors was 189 PJ, 186 PJ, 828.5PJ, 398 PJ, and 50.83 PJ, respectively. On the supply side, the total energy input and output were found to be 644.84 PJ and 239 PJ, respectively. These results, along with the associated energy flows were depicted pictorially using

  5. Primary energy-transformations in biological systems

    Energy Technology Data Exchange (ETDEWEB)

    Lehninger, A.L.

    1980-10-01

    In this paper I shall review the main outlines of current research on the molecular aspects of the primary energy-coupling mechanisms in cells, those carried out by energy-transducing membranes. They include the capture of solar energy by the chloroplast membranes of green plants, used to generate carbohydrates and molecular oxygen from carbon dioxide and water, and the counterpart of photosynthesis, the process of respiration in heterotrophic organisms, in which reduced organic products generated by photosynthesis are oxidized at the expense of dioxygen to form carbon dioxide and water. Although the cycling of dioxygen, carbon dioxide, and organic matter between the plant and animal worlds is well known, it is not generally appreciated that the magnitude of biological energy flux in these cycles is huge compared to the total energy flux in man-made devices. A major consequence is that the concentration of carbon dioxide in the atmosphere has been increasing at a significant rate, at a time when there is also a decrease, at least in some parts of the world, in the counterbalancing utilization of CO/sub 2/ by green plants, due to deforestation. The greenhouse effect of increased atmospheric CO/sub 2/ may not only change the earth's climate, but also may influence the rate of photosynthesis. It is also not generally appreciated that energy flow in the biosphere leads to production of enormous amounts of organic matter potentially useful in furnishing man's energy requirements.

  6. Tangible and fungible energy: Hybrid energy market and currency system for total energy management. A Masdar City case study

    International Nuclear Information System (INIS)

    Sgouridis, Sgouris; Kennedy, Scott

    2010-01-01

    We propose the introduction of an energy-based parallel currency as a means to ease the transition to energy-conscious living. Abundant fossil energy resources mask the internal and external energy costs for casual energy consumers. This situation is challenging communities that draw a significant fraction of their primary energy consumption from renewable energy sources. The Masdar Energy Credit (MEC) system is a way of translating the fundamental aspects behind energy generation and usage into a tangible reality for all users with built-in fungibility to incentivize collectively sustainable behavior. The energy credit currency (ergo) corresponds with a chosen unit of energy so that the total amount of ergos issued equals the energy supply of the community. Ergos are distributed to users (residents, commercial entities, employees, and visitors) on a subscription basis and can be surrendered in exchange for the energy content of a service. A spot market pricing mechanism is introduced to relate ergos to 'fiat' currency using a continuously variable exchange rate to prevent depletion of the sustainable energy resource. The MEC system is intended to: (i) meet the sustainable energy balance targets of a community (ii) support peak shaving or load shifting goals, and (iii) raise energy awareness.

  7. Midflexion instability in primary total knee replacement: a review

    Directory of Open Access Journals (Sweden)

    Ramappa Manjunath

    2015-01-01

    Full Text Available Introduction: Midflexion instability in primary total knee replacement (TKR is an evolving concept. Successful treatment of instability requires an understanding of the different types of instability. Methods: A literature review was performed to identify information pertinent to midflexion instability in primary total knee replacement, utilising PRISMA guidelines. Databases searched included Embase, Medline, All of the Cochrane Library, PubMed and cross references. Results: Three factors, i.e., elevated joint line, multiradii femoral component and medial collateral ligament (MCL laxity, were identified to influence midflexion instability. Literature suggested mediolateral instability at 30–60° of flexion as diagnostic of midflexion instability. Literature search also revealed paucity in clinical studies analysing midflexion instability. Most of the evidence was obtained from cadaveric studies for elevated joint line and MCL laxity. Clinical studies on multiradii femoral component were limited by their small study size and early followup period. Conclusion: Elevated joint line, multiradii femoral component and MCL laxity have been suggested to cause midflexion laxity in primary TKR. Due to limitations in available evidence, this review was unable to raise the strength of overall evidence. Future well-designed clinical studies are essential to make definitive conclusions. This review serves as a baseline for future researchers and creates awareness for routine assessment of midflexion instability in primary total knee replacement.

  8. A grey neural network and input-output combined forecasting model. Primary energy consumption forecasts in Spanish economic sectors

    International Nuclear Information System (INIS)

    Liu, Xiuli; Moreno, Blanca; García, Ana Salomé

    2016-01-01

    A combined forecast of Grey forecasting method and neural network back propagation model, which is called Grey Neural Network and Input-Output Combined Forecasting Model (GNF-IO model), is proposed. A real case of energy consumption forecast is used to validate the effectiveness of the proposed model. The GNF-IO model predicts coal, crude oil, natural gas, renewable and nuclear primary energy consumption volumes by Spain's 36 sub-sectors from 2010 to 2015 according to three different GDP growth scenarios (optimistic, baseline and pessimistic). Model test shows that the proposed model has higher simulation and forecasting accuracy on energy consumption than Grey models separately and other combination methods. The forecasts indicate that the primary energies as coal, crude oil and natural gas will represent on average the 83.6% percent of the total of primary energy consumption, raising concerns about security of supply and energy cost and adding risk for some industrial production processes. Thus, Spanish industry must speed up its transition to an energy-efficiency economy, achieving a cost reduction and increase in the level of self-supply. - Highlights: • Forecasting System Using Grey Models combined with Input-Output Models is proposed. • Primary energy consumption in Spain is used to validate the model. • The grey-based combined model has good forecasting performance. • Natural gas will represent the majority of the total of primary energy consumption. • Concerns about security of supply, energy cost and industry competitiveness are raised.

  9. New primary energy source by thorium molten-salt reactor technology

    International Nuclear Information System (INIS)

    Furukawa, Kazuo; Kato, Yoshio; Furuhashi, Akira; Numata, Hiroo; Mitachi, Koushi; Yoshioka, Ritsuo; Sato, Yuzuru; Arakawa, Kazuto

    2005-01-01

    Among the next 30 years, we have to implement a practical measure in the global energy/environmental problems, solving the followings: (1) replacing the fossil fuels without CO 2 emission, (2) no severe accidents, (3) no concern on military, (4) minimizing wastes, (5) economical, (6) few R and D investment and (7) rapid/huge global application supplying about half of the total primary energy till 50 years later. For this purpose the following system was proposed: THORIMS-NES [Thorium Molten-Salt Nuclear Energy Synergetic System], which is composed of (A) simple fission Molten-Salt power stations (FUJI), and (B) fissile-producing Accelerator Molten-Salt Breeder (AMSB). It has been internationally prepared a practical Developmental Program for its huge-size industrialization of Th breeding fuel cycle to produce a new rational primary energy. Here it is explained the social meaning, the conceptual system design and technological bases, especially, including the molten fluoride salt technology, which was developed as the triple-functional medium for nuclear-engineering, heat-transfer and chemical engineering. The complex function of this system is fully achieved by the simplified facility using a single phase molten-salt only. (author)

  10. Trabecular metal acetabular components in primary total hip arthroplasty

    DEFF Research Database (Denmark)

    Laaksonen, Inari; Lorimer, Michelle; Gromov, Kirill

    2018-01-01

    Background and purpose - Trabecular metal (TM) cups have demonstrated favorable results in acetabular revision and their use in primary total hip arthroplasty (THA) is increasing. Some evidence show that TM cups might decrease periprosthetic infection (PPI) incidence. We compared the survivorship...... of TM cups with that of other uncemented cups in primary THA, and evaluated whether the use of TM cups is associated with a lower risk of PPI. Patients and methods - 10,113 primary THAs with TM cup and 85,596 THAs with other uncemented cups from 2 high-quality national arthroplasty registries were...

  11. Total-factor energy efficiency of regions in China

    International Nuclear Information System (INIS)

    Hu, J.-L.; Wang, S.-C.

    2006-01-01

    This paper analyzes energy efficiencies of 29 administrative regions in China for the period 1995-2002 with a newly introduced index. Most existing studies of regional productivity and efficiency neglect energy inputs. We use the data envelopment analysis (DEA) to find the target energy input of each region in China at each particular year. The index of total-factor energy efficiency (TFEE) then divides the target energy input by the actual energy input. In our DEA model, labor, capital stock, energy consumption, and total sown area of farm crops used as a proxy of biomass energy are the four inputs and real GDP is the single output. The conventional energy productivity ratio regarded as a partial-factor energy efficiency index is computed for comparison in contrast to TFEE; our index is found fitting better to the real case. According to the TFEE index rankings, the central area of China has the worst energy efficiency and its total adjustmentof energy consumption amount is over half of China's total. Regional TFEE in China generally improved during the research period except for the western area. A U-shape relation between the area's TFEE and per capita income in the areas of China is found, confirming the scenario that energy efficiency eventually improves with economic growth

  12. Industry-level total-factor energy efficiency in developed countries: A Japan-centered analysis

    International Nuclear Information System (INIS)

    Honma, Satoshi; Hu, Jin-Li

    2014-01-01

    Highlights: • This study compares Japan with other developed countries for energy efficiency at the industry level. • We compute the total-factor energy efficiency (TFEE) for industries in 14 developed countries in 1995–2005. • Energy conservation can be further optimized in Japan’s industry sector. • Japan experienced a slight decrease in the weighted TFEE from 0.986 in 1995 to 0.927 in 2005. • Japan should adapt energy conservation technologies from the primary benchmark countries: Germany, UK, and USA. - Abstract: Japan’s energy security is more vulnerable today than it was before the Fukushima Daiichi nuclear power plant accident in March 2011. To alleviate its energy vulnerability, Japan has no choice but to improve energy efficiency. To aid in this improvement, this study compares Japan’s energy efficiency at the industry level with that of other developed countries. We compute the total-factor energy efficiency (TFEE) of industries in 14 developed countries for 1995–2005 using data envelopment analysis. We use four inputs: labor, capital stock, energy, and non-energy intermediate inputs. Value added is the only relevant output. Results indicate that Japan can further optimize energy conservation because it experienced only a marginal decrease in the weighted TFEE, from 0.986 in 1995 to 0.927 in 2005. To improve inefficient industries, Japan should adapt energy conservation technologies from benchmark countries such as Germany, the United Kingdom, and the United States

  13. Total Quality Management Practices in Turkish Primary Schools

    Science.gov (United States)

    Toremen, Fatih; Karakus, Mehmet; Yasan, Tezcan

    2009-01-01

    Purpose: The purpose of this paper is to determine the extent of total quality management (TQM) practices in primary schools based on teachers' perceptions, and how their perceptions are related to different variables. Design/methodology/approach: In this study, a survey based descriptive scanning model was used. This study was carried out in…

  14. Thermodynamics of greenhouse systems for the northern latitudes: analysis, evaluation and prospects for primary energy saving.

    Science.gov (United States)

    Bronchart, Filip; De Paepe, Michel; Dewulf, Jo; Schrevens, Eddie; Demeyer, Peter

    2013-04-15

    In Flanders and the Netherlands greenhouse production systems produce economically important quantities of vegetables, fruit and ornamentals. Indoor environmental control has resulted in high primary energy use. Until now, the research on saving primary energy in greenhouse systems has been mainly based on analysis of energy balances. However, according to the thermodynamic theory, an analysis based on the concept of exergy (free energy) and energy can result in new insights and primary energy savings. Therefore in this paper, we analyse the exergy and energy of various processes, inputs and outputs of a general greenhouse system. Also a total system analysis is then performed by linking the exergy analysis with a dynamic greenhouse climate growth simulation model. The exergy analysis indicates that some processes ("Sources") lie at the origin of several other processes, both destroying the exergy of primary energy inputs. The exergy destruction of these Sources is caused primarily by heat and vapour loss. Their impact can be compensated by exergy input from heating, solar radiation, or both. If the exergy destruction of these Sources is reduced, the necessary compensation can also be reduced. This can be accomplished through insulating the greenhouse and making the building more airtight. Other necessary Sources, namely transpiration and loss of CO2, have a low exergy destruction compared to the other Sources. They are therefore the best candidate for "pump" technologies ("vapour heat pump" and "CO2 pump") designed to have a low primary energy use. The combination of these proposed technologies results in an exergy efficient greenhouse with the highest primary energy savings. It can be concluded that exergy analyses add additional information compared to only energy analyses and it supports the development of primary energy efficient greenhouse systems. Copyright © 2013 Elsevier Ltd. All rights reserved.

  15. Nuclear energy ranks first as primary energy source in Europe in 2012

    International Nuclear Information System (INIS)

    Anon.

    2014-01-01

    According to the 2012 report of Eurostat, nuclear energy represents 30% of the production of primary energy in the member states of the E.U., renewable energies a little less than 20% and fossil energies a little more than 50%. In Europe the production of primary energy has been decreasing since 2001, from 940 million tonnes in 2001 to 794 million tonnes in 2012. In Europe the gross energy consumption has decreased in 24 member states to reach the level of 1995 year. In 2012 the E.U.'s dependence rate for energy was of 53% on average. Only Denmark was a net exporter of energy while the dependence rate for energy of the main E.U. energy consumers were: Germany (61%), Spain (73%), France (48%), United-Kingdom (42%) and Italy (81%). (A.C.)

  16. Multi-ligament instability after early dislocation of a primary total knee replacement - case report.

    Science.gov (United States)

    Sisak, Krisztian; Lloyd, John; Fiddian, Nick

    2011-01-01

    Peripheral nerve blocks have found increased popularity in providing prolonged post-operative analgesia following total knee replacement surgery. They generally provide effective analgesia with fewer complications than epidurals. This report describes an acute low-energy knee dislocation after a well balanced, fixed bearing, cruciate-retaining primary total knee replacement performed under a spinal anaesthetic with combined complimentary femoral and sciatic nerve blocks. The dislocation was not accompanied by neurovascular compromise. Due to the subsequent instability and injury to both collaterals, the posterior cruciate ligament and posterolateral corner structures, the knee was treated with a rotating-hinge revision total knee replacement. The dislocation occurred whilst the peripheral nerve blocks (PNB) were still working. We review our incidence of PNB related complications and conclude that PNB remain a safe and effective analgesia for total knee replacements. However, we advocate that ward staff and patients should be sufficiently educated to ensure that unaided post-operative mobilisation is prevented until such a time that patients have regained complete voluntary muscle control. Copyright © 2009 Elsevier B.V. All rights reserved.

  17. Feasibility study on energy conservation at Sao Paulo state primary schools in the Federative Republic of Brazil

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-03-01

    A feasibility study has been performed on the energy conservation project aimed at the future CDM in relation with energy consumption in the lighting equipment at the Sao Paulo state primary schools in the Federative Republic of Brazil. Out of about 5,500 primary schools existing in Sao Paulo, 3,414 schools were selected as the objects of the surveys and discussions. The present program intends to introduce energy saving facilities such as high-efficiency fluorescent lamps and controls for illuminating the primary schools to save the energies and reduce emission of the global warming gases. In this economy project, the owners do not need to make initial investments, wherein the required funds are taken care by conservation of electric power during the service contract period. If about 3,000 schools are selected as the object, a fund of about 2.3 billion yen will be required in total. Total energy conservation quantity during 15 years from 2002 to 2016 as achieved by this project will be 532,740 MWh, corresponding to 114,540 tons of crude oil. The effect of reducing the emission of global warming gases will be 110,949 t-CO2 during the same period of time. (NEDO)

  18. Primary vs Conversion Total Hip Arthroplasty: A Cost Analysis

    Science.gov (United States)

    Chin, Garwin; Wright, David J.; Snir, Nimrod; Schwarzkopf, Ran

    2018-01-01

    Introduction Increasing hip fracture incidence in the United States is leading to higher occurrences of conversion total hip arthroplasty (THA) for failed surgical treatment of the hip. In spite of studies showing higher complication rates in conversion THA, the Centers for Medicare and Medicaid services currently bundles conversion and primary THA under the same diagnosis-related group. We examined the cost of treatment of conversion THA compared with primary THA. Our hypothesis is that conversion THA will have higher cost and resource use than primary THA. Methods Fifty-one consecutive conversion THA patients (Current Procedure Terminology code 27132) and 105 matched primary THA patients (Current Procedure Terminology code 27130) were included in this study. The natural log-transformed costs for conversion and primary THA were compared using regression analysis. Age, gender, body mass index, American Society of Anesthesiologist, Charlson comorbidity score, and smoker status were controlled in the analysis. Conversion THA subgroups formed based on etiology were compared using analysis of variance analysis. Results Conversion and primary THAs were determined to be significantly different (P conversion THA has significantly greater cost and resource use than primary THA. In order to prevent disincentives for treating these complex surgical patients, reclassification of conversion THA is needed, as they do not fit together with primary THA. PMID:26387923

  19. Primary cemented total hip arthroplasty: 10 years follow-up

    Directory of Open Access Journals (Sweden)

    Nath Rajendra

    2010-01-01

    Full Text Available Background: Primary cemented total hip arthroplasty is a procedure for non-traumatic and traumatic affections of the hip. Long term follow-up is required to assess the longevity of the implant and establish the procedure. Indo-Asian literature on long term result of total hip arthroplasty is sparse. We present a 10-year follow-up of our patients of primary cemented total hip arthroplasty. Materials and Methods: We operated 31 hips in 30 patients with primary cemented total hip arthroplasty. We followed the cases for a minimum period of 10 years with a mean follow-up period of 12.7 years. The mean age of the patients was 60.7 years (range 37-82 yrs male to female ratio was 2:1. The clinical diagnoses included - avascular necrosis of femoral head (n=15, sero positive rheumatoid arthritis (n=5, seronegative spondylo-arthropathy (n=4, neglected femoral neck fractures (n=3, healed tubercular arthritis (n=2 and post traumatic osteoarthritis of hip (n=2. The prostheses used were cemented Charnley′s total hip (n=12 and cemented modular prosthesis (n=19. The results were assessed according to Harris hip score and radiographs taken at yearly intervals. Results: The mean follow-up is 12.7 yrs (range 11-16 yrs Results in all operated patients showed marked improvement in Harris hip score from preoperative mean 29.2 to 79.9 at 10 years or more followup. However, the non-inflammatory group showed more sustained long term improvement as compared to the inflammatory group, as revealed by the Harris hip score. Mean blood loss was 450ml (±3.7 ml, mean transfusion rate was 1.2 units (±.3. The complications were hypotension (n=7, shortening> 1.5 cm (n=9, superficial infection (n=2 and malposition of prosthesis (n=1. Conclusion: The needs of Indian Asian patients, vary from what is discussed in literature. The pain tolerance is greater than western population and financial constraints are high. Thus revision surgery among Indian-Asian patients is less compared

  20. Preoperative predictors of returning to work following primary total knee arthroplasty.

    Science.gov (United States)

    Styron, Joseph F; Barsoum, Wael K; Smyth, Kathleen A; Singer, Mendel E

    2011-01-05

    There is little in the literature to guide clinicians in advising patients regarding their return to work following a primary total knee arthroplasty. In this study, we aimed to identify which factors are important in estimating a patient's time to return to work following primary total knee arthroplasty, how long patients can anticipate being off from work, and the types of jobs to which patients are able to return following primary total knee arthroplasty. A prospective cohort study was performed in which patients scheduled for a primary total knee arthroplasty completed a validated questionnaire preoperatively and at four to six weeks, three months, and six months postoperatively. The questionnaire assessed the patient's occupational physical demands, ability to perform job responsibilities, physical status, and motivation to return to work as well as factors that may impact his or her recovery and other workplace characteristics. Two survival analysis models were constructed to evaluate the time to return to work either at least part-time or full-time. Acceleration factors were calculated to indicate the relative percentage of time until the patient returned to work. The median time to return to work was 8.9 weeks. Patients who reported a sense of urgency about returning to work were found to return in half the time taken by other employees (acceleration factor = 0.468; p mental health scores (acceleration factor = 0.891), higher physical function scores (acceleration factor = 0.809), higher Functional Comorbidity Index scores (acceleration factor = 0.914), and a handicap accessible workplace (acceleration factor = 0.736). A slower return to work was associated with having less pain preoperatively (acceleration factor = 1.132), having a more physically demanding job (acceleration factor = 1.116), and receiving Workers' Compensation (acceleration factor = 4.360). Although the physical demands of a patient's job have a moderate influence on the patient's ability

  1. Poorer survival after a primary implant during revision total knee arthroplasty

    NARCIS (Netherlands)

    Meijer, Marrigje F.; Reininga, Inge H. F.; Boerboom, Alexander L.; Stevens, Martin; Bulstra, Sjoerd K.

    Revision total knee arthroplasty (rTKA) is a complex procedure. Depending on the degree of ligament and bone damage, either primary or revision implants are used. The purpose of this study was to compare survival rates of primary implants with revision implants when used during rTKA. A retrospective

  2. International survey of primary and revision total knee replacement

    NARCIS (Netherlands)

    Kurtz, Steven M.; Ong, Kevin L.; Lau, Edmund; Widmer, Marcel; Maravic, Milka; Gomez-Barrena, Enrique; de Pina, Maria de Fatima; Manno, Valerio; Torre, Marina; Walter, William L.; de Steiger, Richard; Geesink, Rudolph G. T.; Peltola, Mikko; Roeder, Christoph

    2011-01-01

    Total knee arthroplasty (TKA) is currently the international standard of care for treating degenerative and rheumatologic knee joint disease, as well as certain knee joint fractures. We sought to answer the following three research questions: (1) What is the international variance in primary and

  3. Energy management for cost reduction in the production. TEEM - Total Energy Efficiency Management; Energiemanagement zur Kostensenkung in der Produktion. TEEM - Total Energy Efficiency Management

    Energy Technology Data Exchange (ETDEWEB)

    Westkaemper, Engelbert; Verl, Alexander (eds.)

    2009-07-01

    Within the workshop of the Fraunhofer Institute for Manufacturing Engineering and Automation IPA (Stuttgart, Federal Republic of Germany) at 6th October, 2009, in Stuttgart the following lectures were held: (1) Presentation of Fraunhofer Institute for Manufacturing Engineering and Automation IPA (Engelbert Westkaemper); (2) TEEM - Total Energy Efficiency Management - ''With energy management to an energy efficient production'' (Alexander Schloske); (3) DIN EN 16001 Introduction of an energy management system - utilization and advantages for companies (Sylvia Wahren); (4) Analysis of the energy efficiency with power flow - Support and implementation at factory planning and optimization of production (Klaus Erlach); (5) Total Energy Efficiency Management - Approaches at the company Kaercher in injection moulding for example (Axel Leschtar); (6) Modelling the embodied product energy (Shahin Rahimifard); (7) Acquisition of energy data in the production - Technologies and possibilities (Joachim Neher); (8) Active energy management by means of an ''energy control centre'' - Analysis of the real situation and upgrading measures in the production using coating plants as an example (Wolfgang Klein); (9) Visualisation and simulation of energy values in the digital factory (Carmen Constantinescu, Axel Bruns).

  4. Forecasting of primary energy consumption data in the United States: A comparison between ARIMA and Holter-Winters models

    Science.gov (United States)

    Rahman, A.; Ahmar, A. S.

    2017-09-01

    This research has a purpose to compare ARIMA Model and Holt-Winters Model based on MAE, RSS, MSE, and RMS criteria in predicting Primary Energy Consumption Total data in the US. The data from this research ranges from January 1973 to December 2016. This data will be processed by using R Software. Based on the results of data analysis that has been done, it is found that the model of Holt-Winters Additive type (MSE: 258350.1) is the most appropriate model in predicting Primary Energy Consumption Total data in the US. This model is more appropriate when compared with Holt-Winters Multiplicative type (MSE: 262260,4) and ARIMA Seasonal model (MSE: 723502,2).

  5. Early Removal of Drainage Tube after Fast-Track Primary Total Knee Arthroplasty.

    Science.gov (United States)

    Zhang, Shaoyun; Xu, Bin; Huang, Qiang; Yao, Huan; Xie, Jinwei; Pei, Fuxing

    2017-07-01

    There is no consensus as to whether drainage tube should be used and how long it should remain in use after primary total knee arthroplasty (TKA). As fast-track (FT) program has been implemented in TKA, whether drainage tube could be removed early, and the ideal timing for removal after FT primary TKA has been a new topic. The purpose of this prospective cohort study was to evaluate the safety and feasibility of early removal of drainage tube when FT program was implemented in primary TKA. A total of 101 patients undergoing FT primary TKA were prospectively allocated into three groups. Patients in group A (31 patients) indwelled wound drainage tube for 6 hours after surgery while group B (34 patients) for 12 hours and group C (36 patients) for 18 hours. The knee circumference, resting and moving visual analogue score (VAS), hemoglobin (Hb), hematocrit, white blood count (WBC), erythrocyte sedimentation rate (ESR), C-reactive protein (CRP), interleukin-6 (IL-6), the volume of blood loss and drainage, and postoperative length of stay (LOS) among three groups were recorded and compared. There was no statistically significant difference in the volume of total and hidden blood loss among three groups ( p  > 0.05), but as the time of drainage prolonged, total volume of drainage and dominant blood loss increased gradually ( p   0.05), the decrease of Hb in the perioperative period and postoperative LOS as well. Early removal of wound drainage tube could drain the hematocele and reduce the risk of infection, and it doesn't increase the sense of pain, inflammatory reaction, limb swelling, and total blood loss. It's safe and feasible to remove the drainage tube within 6 to 12 hours after FT primary TKA. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  6. 78 FR 10269 - National Primary Drinking Water Regulations: Revisions to the Total Coliform Rule

    Science.gov (United States)

    2013-02-13

    ... Illness CWS--Community Water System DBP--Disinfection Byproduct DWC--Drinking Water Committee EA--Economic... 141 and 142 National Primary Drinking Water Regulations: Revisions to the Total Coliform Rule; Final...-9684-8] RIN 2040-AD94 National Primary Drinking Water Regulations: Revisions to the Total Coliform Rule...

  7. Total energy consumption in Finland increased by one percent

    International Nuclear Information System (INIS)

    Timonen, L.

    2000-01-01

    The total energy consumption in Finland increased by less than a percent in 1999. The total energy consumption in 1999 was 1310 PJ corresponding to about 31 million toe. The electric power consumption increased moderately by 1.6%, which is less than the growth of the gross national product (3.5%). The final consumption of energy grew even less, only by 0.5%. Import of electric power increased by 19% in 1999. The import of electric power was due to the availability of low-priced electric power on the Nordic electricity markets. Nuclear power generation increased by 5% and the consumption of wood-based fuels by 3%. The increment of the nuclear power generation increased because of the increased output capacity and good operability of the power plants. Wind power production doubles, but the share of it in the total energy consumption is only about 0.01%. The peat consumption decreased by 12% and the consumption of hydroelectric power by 15%. The decrease in production of hydroelectric power was compensated by an increase import of electric power. The consumption of fossil fuels, coal, oil and natural gas remained nearly the same as in 1998. The gasoline consumption, however, decreased, but the consumption of diesel oil increased due to the increased road transport. The share of the fossil fuels was nearly half of the total energy consumption. The consumption of renewable energy sources remained nearly the same, in 23% if the share of peat is excluded, and in 30% if the share of peat is included. Wood-based fuels are the most significant type of renewable fuels. The share of them in 1999 was over 80% of the total usage of the renewable energy sources. The carbon dioxide emissions in Finland decreased in 1999 by 1.0 million tons. The total carbon dioxide emissions were 56 million tons. The decrease was mainly due to the decrease of the peat consumption. The final consumption of energy increased by 0.5%, being hence about 1019 PJ. Industry is the main consumer of energy

  8. Optimized design of total energy systems: The RETE project

    Science.gov (United States)

    Alia, P.; Dallavalle, F.; Denard, C.; Sanson, F.; Veneziani, S.; Spagni, G.

    1980-05-01

    The RETE (Reggio Emilia Total Energy) project is discussed. The total energy system (TES) was developed to achieve the maximum quality matching on the thermal energy side between plant and user and perform an open scheme on the electrical energy side by connection with the Italian electrical network. The most significant qualitative considerations at the basis of the plant economic energy optimization and the selection of the operating criterion most fitting the user consumption characteristics and the external system constraints are reported. The design methodology described results in a TES that: in energy terms achieves a total efficiency evaluated on a yearly basis to be equal to about 78 percent and a fuel saving of about 28 percent and in economic terms allows a recovery of the investment required as to conventional solutions, in about seven years.

  9. Total thyroidectomy as primary elective procedure in multinodular thyroid disease

    International Nuclear Information System (INIS)

    Sheikh, I.A.; Haider, I.Z.; Haroon, A.; Ashfaq, M.

    2009-01-01

    Multinodular goitre is one of the commonest thyroid diseases encountered in the practice of surgery. The most common surgery being performed for multinodular goitre is subtotal thyroidectomy. Total thyroidectomy is designed to remove all of the thyroid tissue. The objective of this study was to evaluate total thyroidectomy as a primary elective procedure for treatment of multinodular thyroid disease. This descriptive study was carried out at Combined Military Hospital Rawalpindi from June 2003 to September 2006. 88 patients of multinodular thyroid disease were included. Patients having evidence of recurrent laryngeal nerve damage, recurrent goitre, evidence of altered parathyroid functions or evidence of malignancy were excluded. All patients underwent total thyroidectomy by the same team of surgeons and the patients were closely followed up for postoperative complications especially in terms of recurrent laryngeal nerve damage and hypocalcaemic tetany. No major postoperative complication was noted. Only 1 patient (1.14%) developed unilateral recurrent laryngeal nerve damage and 2 patients (2.27%) developed transient hypocalcaemia that recovered quickly. Total thyroidectomy as a primary elective procedure in multinodular thyroid disease is a safe option and it removes the disease process completely, lowers local recurrence rates and avoids the substantial risks of re operative surgery. (author)

  10. Atomic resonances above the total ionization energy

    International Nuclear Information System (INIS)

    Doolen, G.

    1975-01-01

    A rigorous result obtained using the theory associated with dilatation analytic potentials is that by performing a complex coordinate rotation, r/subj/ → r/subj/e/subi//sup theta/, on a Hamiltonian whose potential involves only pairwise Coulombic interactions, one can show that when theta = π/2, no complex eigenvalues (resonances) appear whose energies have a real part greater than the total ionization energy of the atomic system. This appears to conflict with experimental results of Walton, Peart, and Dolder, who find resonance behavior above the total ionization energy of the H -- system and also the theoretical stabilization results of Taylor and Thomas for the same system. A possible resolution of this apparent conflict is discussed and a calculation to check its validity is proposed

  11. Primary total hip replacement versus hip resurfacing - hospital considerations.

    Science.gov (United States)

    Ward, William G; Carter, Christina J; Barone, Marisa; Jinnah, Riyaz

    2011-01-01

    Multiple factors regarding surgical procedures and patient selection affect hospital staffing needs as well as hospital revenues. In order to better understand the potential impact on hospitals that hip arthroplasty device selection (standard total hip arthroplasty vs. resurfacing) creates, a review of all primary hip arthroplasties performed at one institution was designed to identify factors that impacted hospital staffing needs and revenue generation. All primary hip arthroplasties undertaken over three fiscal years (2008 to 2010) were reviewed, utilizing only hospital business office data and medical records data that had been previously extracted prior for billing purposes. Analysis confirmed differing demographics for two hip arthroplasty populations, with the resurfacing patients (compared to the conventional total hip arthroplasty population) consisting of younger patients (mean age, 50 vs. 61 years), who were more often male (75% vs. 45%), were more likely to have osteoarthritis as their primary diagnosis (83 vs. 67%) and were more often covered by managed care or commercial insurance (83 vs. 34%). They also had shorter hospital stays (mean length of stay, 2.3 vs. 4.1 days) and consequently provided a more favorable financial revenue stream to the hospital on a per patient basis. Several trends appeared during the study periods. There was a steady increase in all procedures in all groups except for the resurfacings, which decreased 26% in males and 53% in females between 2009 and 2010. Differences were observed in the demographics of patients presenting for resurfacing, compared to those presenting for conventional total hip arthroplasty. In addition to the revenue stream considerations, institutions undertaking a resurfacing program must commit the resources and planning in order to rehabilitate these patients more expeditiously than is usually required with conventional hip arthroplasty patients.

  12. Total elbow arthroplasty for primary osteoarthritis.

    Science.gov (United States)

    Schoch, Bradley S; Werthel, Jean-David; Sánchez-Sotelo, Joaquín; Morrey, Bernard F; Morrey, Mark

    2017-08-01

    Primary osteoarthritis of the elbow is a less common indication for total elbow arthroplasty (TEA). Higher complication rates in younger, active patients may offset short-term improvements in pain and function. The purpose of this study was to determine pain relief, functional outcomes, complications, and survival of TEA in this population. Between 1984 and 2011, 20 consecutive TEAs were performed for primary elbow osteoarthritis. Two patients died before the 2-year follow-up. Mean age at surgery was 68 years (range, 51-85 years). Outcome measures included pain, motion, Mayo Elbow Performance Score, satisfaction, complications, and reoperations. Mean follow-up was 8.9 years (range, 2-20 years). Three elbows sustained mechanical failures. Complications included intraoperative fracture (n = 2), wound irrigation and débridement (n = 1), bony ankylosis (n = 1), humeral loosening (n = 1), humeral component fracture (n = 1), and mechanical failure of a radial head component (n = 1). Fifteen elbows without mechanical failure were examined clinically. Pain improved from 3.6 to 1.5 (P  .05), with preoperative flexion contractures not improving. Mayo Elbow Performance Scores were available for 13 elbows without mechanical failure, averaging 81.5 points (range, 60-100 points); these were graded as excellent (n = 5), good (n = 2), and fair (n = 6). Subjectively, all patients without mechanical failure were satisfied. TEA represents a reliable surgical option for pain relief in patients with primary osteoarthritis. However, restoration of extension is not always obtained, indicating that more aggressive soft tissue releases or bony resection should be considered. Complications occurred in a large number of elbows, but mechanical failure was low considering the nature of this population and the length of follow-up. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  13. Experimental evaluation of the primary damage process: neutron energy effects

    Energy Technology Data Exchange (ETDEWEB)

    Goland, A.N.

    1979-01-01

    Experimental evaluation of the neutron energy dependnece of the primary damage stage depends upon a number of theoretical concepts. This state can only be observed after low- or perhaps ambient-temperature, low-fluence irradiations. The primary recoil energy spectrum, which determines the character of the displacement cascades, can be calculated if dosimetry has provided an accurate neutron spectrum. A review of experimental results relating neutron-energy effects shows that damage energy or damage energy cross section has often been a reliable correlation parameter for primary damage state experiments. However, the forthcoming emphasis on higher irradiation temperatures, more complex alloys and microstructural evolution has fostered a search for additional meaningful correlation parameters.

  14. The Use of Trust Regions in Kohn-Sham Total Energy Minimization

    International Nuclear Information System (INIS)

    Yang, Chao; Meza, Juan C.; Wang, Lin-wang

    2006-01-01

    The Self Consistent Field (SCF) iteration, widely used for computing the ground state energy and the corresponding single particle wave functions associated with a many-electron atomistic system, is viewed in this paper as an optimization procedure that minimizes the Kohn-Sham total energy indirectly by minimizing a sequence of quadratic surrogate functions. We point out the similarity and difference between the total energy and the surrogate, and show how the SCF iteration can fail when the minimizer of the surrogate produces an increase in the KS total energy. A trust region technique is introduced as a way to restrict the update of the wave functions within a small neighborhood of an approximate solution at which the gradient of the total energy agrees with that of the surrogate. The use of trust region in SCF is not new. However, it has been observed that directly applying a trust region based SCF(TRSCF) to the Kohn-Sham total energy often leads to slow convergence. We propose to use TRSCF within a direct constrained minimization(DCM) algorithm we developed in dcm. The key ingredients of the DCM algorithm involve projecting the total energy function into a sequence of subspaces of small dimensions and seeking the minimizer of the total energy function within each subspace. The minimizer of a subspace energy function, which is computed by TRSCF, not only provides a search direction along which the KS total energy function decreases but also gives an optimal 'step-length' that yields a sufficient decrease in total energy. A numerical example is provided to demonstrate that the combination of TRSCF and DCM is more efficient than SCF

  15. Economics of total energy schemes in the liberalised European energy market

    Science.gov (United States)

    Lampret, Peter

    This thesis is concerned with the liberalisation of the European Energy markets and the affects this has had on total energy systems. The work concentrates on a number of case studies all of which are located in the area surrounding Gelsenkirchen - Bottrop - Gladbeck, the centre of the Ruhr region of Germany.The thesis describes briefly how the legislation of the parliament of the extended European Union has been interpreted and enacted into German legislation and its affects on production, transport, sales and customers. Primarily the legislation has been enacted to reduce energy costs by having a competitive market while enabling security of supply. The legislation whose development has accelerated since 1999 can lead to negative effects and these have been highlighted for the case studies chosen.The legislation and technological advances, each of them successful by themselves, do not provide the expected reduction of carbon dioxide emissions when applied to total energy system. The introduction of human behaviour as a missing link makes the problems evident and gives a theoretical basis to overcome these problems. The hypothesis is proven by eight detailed research projects and four concisely described ones.The base of the research is the experience gained on approximately 1,000 operation years of the simplest total energy system, that of centralised heating. This experience is transferred to different solutions for total energy systems and their economics in combination with the changing legislation and observation of human behaviour.The variety of topics of the case studies includes the production of heat by boiler, solar or combined heat and power and the use of fuel cells. Additionally the transfer of heat, at the place of demand is considered, either as an individual boiler in a building or as de-centralised district heating.The various results of these projects come together in a final project which covers four different heating systems in identical

  16. Trigeneration primary energy saving evaluation for energy planning and policy development

    International Nuclear Information System (INIS)

    Chicco, Gianfranco; Mancarella, Pierluigi

    2007-01-01

    Trigeneration or combined heat, cooling and power (CHCP) is becoming an increasingly important energy option, particularly on a small-scale basis (below 1 MW e ), with several alternatives nowadays available for the cooling power production and the coupling to cogeneration systems. This paper deals with the introduction of a suitable framework for assessing the energy saving performance of trigeneration alternatives, orientated towards energy planning studies and the development of regulatory policies. In particular, a new generalized performance indicator-the trigeneration primary energy saving (TPES)-is introduced and discussed, with the aim of effectively evaluating the primary energy savings from different CHCP alternatives. The potential of the TPES indicator is illustrated through specific analyses run over different combinations of trigeneration equipment, providing numerical examples based on time-domain simulations to illustrate the dependence of the energy saving characteristics on the CHCP system configurations and equipment, as well as on the loading levels. In addition, the key aspect of adequately establishing the reference efficiencies for the conventional separate production of electrical, thermal and cooling power is addressed in detail. This aspect affects both equipment selection and potential profitability of the considered solutions under the outlook of receiving financial incentives

  17. Statistical properties of kinetic and total energy densities in reverberant spaces

    DEFF Research Database (Denmark)

    Jacobsen, Finn; Molares, Alfonso Rodriguez

    2010-01-01

    Many acoustical measurements, e.g., measurement of sound power and transmission loss, rely on determining the total sound energy in a reverberation room. The total energy is usually approximated by measuring the mean-square pressure (i.e., the potential energy density) at a number of discrete....... With the advent of a three-dimensional particle velocity transducer, it has become somewhat easier to measure total rather than only potential energy density in a sound field. This paper examines the ensemble statistics of kinetic and total sound energy densities in reverberant enclosures theoretically...... positions. The idea of measuring the total energy density instead of the potential energy density on the assumption that the former quantity varies less with position than the latter goes back to the 1930s. However, the phenomenon was not analyzed until the late 1970s and then only for the region of high...

  18. Age and Early Revision After Primary Total Hip Arthroplasty for Osteoarthritis.

    Science.gov (United States)

    Meyer, Zachary; Baca, Geneva; Rames, Richard; Barrack, Robert; Clohisy, John; Nam, Denis

    2017-11-01

    Prior reports have noted an increased risk of early revision among younger patients undergoing total hip arthroplasty (THA) but have been confounded by the inclusion of various diagnoses. The purpose of this study was to assess the revision rate and the time to revision for patients undergoing THA for osteoarthritis based on age. Patients with a diagnosis of osteoarthritis who underwent both primary and revision THA at the same institution were identified. The time between primary and revision surgery and the indication for revision were collected. Patients were stratified into 2 groups based on age at the time of primary THA: 64 years or younger (group 1) or 65 years or older (group 2). Between 1996 and 2016, a total of 4662 patients (5543 hips) underwent primary THA for a diagnosis of osteoarthritis. Of these, 100 patients (104 hips) received a revision THA (62 in group 1 and 42 in group 2). Mean age was 52.7±8.4 years in group 1 vs 73.4±6.3 years in group 2 (Pprimary to revision surgery was 3.0±3.2 years for group 1 and 1.1±2.1 years for group 2 (P=.001). Among patients undergoing primary THA for a diagnosis of osteoarthritis, younger age is not associated with an increased rate of early failure or revision. [Orthopedics. 2017; 40(6):e1069-e1073.]. Copyright 2017, SLACK Incorporated.

  19. Achievement report on surveys and researches in the Sunshine Project in fiscal 1980. Surveys and researches on total energy systems; 1980 nendo total energy system ni kansuru chosa kenkyu seika hokokusho yoyaku

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1981-06-01

    Identifying the energy demand system as a total system covering from energy generation to the ultimate utilization, a quantitative and theoretical analysis method was developed in achieving selection and development of long-term strategy of Japan for 50 years from about 1975 to about 2025. Development was made on a supply estimation model by using the system dynamics method, that includes international fluctuation factors in primary energy supply structure and time-based relevant elements. Improvements were made in several occasions on the demand estimation model that includes movements of Japan's industrial structures and nation's needs for living, and fluctuation factors of population configuration. Development and improvement were made on the energy flow model to link the supply side with the demand side and analyze the energy flow. In addition, efforts were made on arranging data for inputting these models (data collection, putting them in order, and processing). These models are now in the phase of practical use, and three models have also been nearly completed. Quantitative analysis will be possible if arranging the input database is continued. (NEDO)

  20. The total Hartree-Fock energy-eigenvalue sum relationship in atoms

    International Nuclear Information System (INIS)

    Sen, K.D.

    1979-01-01

    Using the well known relationships for the isoelectronic changes in the total Hartree-Fock energy, nucleus-electron attraction energy and electron-electron repulsion energy in atoms a simple polynomial expansion in Z is obtained for the sum of the eigenvalues which can be used to calculate the total Hartree-Fock energy. Numerical results are presented for 2-10 electron series to show that the present relationship is a better approximation than the other available energy-eigenvalue relationships. (author)

  1. Energy Inputs Uncertainty: Total Amount, Distribution and Correlation Between Different Forms of Energy

    Science.gov (United States)

    Deng, Yue

    2014-01-01

    Describes solar energy inputs contributing to ionospheric and thermospheric weather processes, including total energy amounts, distributions and the correlation between particle precipitation and Poynting flux.

  2. Incidence of Early Post Operative Infection after Primary Total Knee ...

    African Journals Online (AJOL)

    Incidence of Early Post Operative Infection after. Primary Total Knee Arthroplasty at an East African. Centre. Kigera JWM1, Kimpiatu P2. 1. School of Medicine, University of Nairobi. 2. PCEA Kikuyu Hospital. Correspondence to: Dr James Kigera, P.O Box 30197 – 00100 Nairobi. Email: jameskigera@yahoo.co.uk. Abstract.

  3. Energy Resource Planning. Optimal utilization of energy resources

    International Nuclear Information System (INIS)

    Miclescu, T.; Domschke, W.; Bazacliu, G.; Dumbrava, V.

    1996-01-01

    For a thermal power plants system, the primary energy resources cost constitutes a significant percentage of the total system operational cost. Therefore a small percentage saving in primary energy resource allocation cost for a long term, often turns out to be a significant monetary value. In recent years, with a rapidly changing fuel supply situation, including the impact of energy policies changing, this area has become extremely sensitive. Natural gas availability has been restricted in many areas, coal production and transportation cost have risen while productivity has decreased, oil imports have increased and refinery capacity failed to meet demand. The paper presents a mathematical model and a practical procedure to solve the primary energy resource allocation. The objectives is to minimise the total energy cost over the planning period subject to constraints with regards to primary energy resource, transportation and energy consumption. Various aspects of the proposed approach are discussed, and its application to a power system is illustrated.(author) 2 figs., 1 tab., 3 refs

  4. Matched cohort study of topical tranexamic acid in cementless primary total hip replacement.

    Science.gov (United States)

    Sanz-Reig, Javier; Mas Martinez, Jesus; Verdu Román, Carmen; Morales Santias, Manuel; Martínez Gimenez, Enrique; Bustamante Suarez de Puga, David

    2018-03-29

    Tranexamic acid has been shown to be effective in reducing blood loss after total hip replacement. The purpose of this study was to prospectively assess the effectiveness of topical TXA use to reduce blood loss after primary total hip replacement and to compare these outcomes with those of a matched control group from a similar cohort that did not have received tranexamic acid. This is a prospective matched control study to assess the effect of a 2 g topical tranexamic acid in 50 mL physiological saline solution in total hip replacement. Primary outcomes were hemoglobin and hematocrit drop, and total blood loss. Secondary outcomes were transfusion rates, length of hospital stay, deep vein thrombosis, and pulmonary embolism events. We could match 100 patients to a control group. There were no statistical significantly differences between the two groups. The hemoglobin and hematocrit postoperative values were significantly higher in topical tranexamic acid group than in control group (P tranexamic acid group and 1163 in control group with significant differences (P = 0.001), which meant 34% reduction in total blood loss. Length of stay was lower in topical tranexamic acid group. The risk of deep vein thrombosis and pulmonary events did not increase. A single dose of 2 g tranexamic acid in 50 mL physiological saline solution topical administration was effective and safe in reducing bleeding in patients undergoing unilateral primary non-cemented total hip replacement compared to a matched control group.

  5. Combining total energy and energy industrial center concepts to increase utilization efficiency of geothermal energy

    Science.gov (United States)

    Bayliss, B. P.

    1974-01-01

    Integrating energy production and energy consumption to produce a total energy system within an energy industrial center which would result in more power production from a given energy source and less pollution of the environment is discussed. Strong governmental support would be required for the crash drilling program necessary to implement these concepts. Cooperation among the federal agencies, power producers, and private industry would be essential in avoiding redundant and fruitless projects, and in exploiting most efficiently our geothermal resources.

  6. Medium properties and total energy coupling in underground explosions

    International Nuclear Information System (INIS)

    Kurtz, S.R.

    1975-01-01

    A phenomenological model is presented that allows the direct calculation of the effects of variations in medium properties on the total energy coupling between the medium and an underground explosion. The model presented is based upon the assumption that the shock wave generated in the medium can be described as a spherical blast wave at early times. The total energy coupled to the medium is then simply the sum of the kinetic and internal energies of this blast wave. Results obtained by use of this model indicate that the energy coupling is more strongly affected by the medium's porosity than by its water content. These results agree well with those obtained by summing the energy deposited by the blast wave as a function of range

  7. Energy in Croatia 2004, Annual Energy Report

    International Nuclear Information System (INIS)

    2005-11-01

    Report represents a continuous information source for both national and international public on relations and trends in the Croatian energy system. This edition brings certain changes in the energy topics' outline and broader scope of information compared to the previous editions. However, the representative features of the Croatian energy sector, related to supply and demand of energy at all levels, kept the familiar outlook of presentation.Besides the detailed analysis of energy trends, this edition provides numerous information on capacity, reserves and prices of energy as well as individual energy sources' balances - crude oil and oil derivates, natural gas, electricity, heat, coal and renewable energy sources. In addition, Croatian basic and economic and financial indicators, emission of air pollutants plus basic energy efficiency indicators were presented in order to give better understanding of the Croatian energy sector environment. Finally, there is a special novelty of representing energy balances of the Republic of Croatia made in the compliance with EUROSTAT and IEA methodology for years 2003 and 2004. Total primary energy supply in the Republic of Croatia in 2004 was 4.1 percent higher compared to the previous year. The gross domestic product increased by 3.8 percent over the same period. This means that energy intensity, primary energy supply per unit of gross domestic product, increased by 0.3 percent. Compared to the European Union average Croatian energy intensity was approximately 24 percent higher. Total primary energy production, on the other hand, increased by 11.2 percent due to extremely favourable hydrological conditions. The raise i n hydropower by 48.5 percent improved Croatian primary energy self-supply to 49.6 percent. In the structure of total primary energy supply for 2004, the losses of transmission and distribution of energy were reduced only while the rest of the categories of energy consumption increased. The 3.3 percent increase

  8. Energy in Croatia, Annual Energy Report

    International Nuclear Information System (INIS)

    1998-12-01

    The Ministry of Economic Affairs continues its task of observing and informing about the Croatian energy system. The review consists of the most recent and classified data on 1997 and the previous four years. Compared to previous year, in 1997 the total primary energy supply decreased by 1,3 percent. At the same time the gross domestic product increased by 6,5 percent, thus the energy intensity dropped, which is a positive trend. The energy intensity, the value showing the total energy consumed per unit of gross domestic product, exceeds the level realised by the Western European countries, but it is at the same time more favourable related to the transition economy countries. On the other hand, 1997 saw a decrease in the primary energy production by 8,9 percent, resulting from the decline in the production of natural gas, oil and coal, and naturally, unfavourable hydrological conditions. Thus, own supply dropped to 57 percent, the lowest recorded in the past five years. In 1997 the losses and operational consumption of energy decreased more than the non-energy consumption increased, but despite the decrease of the total primary energy supply there occurred an increase of final energy demand by total of 4,4 percent, 2,1 of which in general consumption, 5,5 in transport and 7,8 percent in industry. Apart from these data, the review considers all other relevant indicators showing a positive shift but leaving space for further improvements with the aim of achieving higher energy system efficiency

  9. [Review of wireless energy transmission system for total artificial heart].

    Science.gov (United States)

    Zhang, Chi; Yang, Ming

    2009-11-01

    This paper sums up the fundamental structure of wireless energy transmission system for total artificial heart, and compares the key parameters and performance of some representative systems. After that, it is discussed that the future development trend of wireless energy transmission system for total artificial heart.

  10. In adolescence a higher 'eveningness in energy intake' is associated with higher total daily energy intake.

    Science.gov (United States)

    Diederichs, Tanja; Perrar, Ines; Roßbach, Sarah; Alexy, Ute; Buyken, Anette E

    2018-05-26

    The present manuscript addressed two hypotheses: (i) As children age, energy intake is shifted from morning (energy intake energy intake >6pm) (ii) A higher 'eveningness in energy intake' (i.e. evening minus morning energy intake) is associated with a higher total daily energy intake. Data were analyzed from 262 DONALD cohort study participants, who had completed at least one 3-day weighed dietary record in the age groups 3/4, 5/6, 7/8, 9/10, 11/12, 13/14, 15/16 and 17/18 years (y). 'Eveningness in energy intake' was compared across age groups and related to total daily energy intake for each age group (multiple cross-sectional analyses). 'Eveningness' increased progressively from age group 3/4y to age group 17/18y. A median surplus of evening energy intake (i.e. when evening intake exceeded morning intake) was firstly observed for age group 11/12y. From age group 11/12y onwards, a higher 'eveningness' was associated with a higher total daily energy intake (all p energy intake between the highest and the lowest tertile of 'eveningness' was largest for age group 17/18y, amounting to an 11% higher intake among adolescents in the highest as compared to those in the lowest tertile. In conclusion, energy intake progressively shifts from morning to evening hours as children age. Once evening energy intake exceeds morning energy intake, a higher 'eveningness in energy intake' is associated with higher total daily energy intake. Copyright © 2018 Elsevier Ltd. All rights reserved.

  11. Total Cross Sections at High Energies An update

    CERN Document Server

    Fazal-e-Aleem, M; Alam, Saeed; Qadee-Afzal, M

    2002-01-01

    Current and Future measurements for the total cross sections at E-811, PP2PP, CSM, FELIX and TOTEM have been analyzed using various models. In the light of this study an attempt has been made to focus on the behavior of total cross section at very high energies.

  12. Prospective Assessment of Sleep Quality Before and After Primary Total Joint Replacement.

    Science.gov (United States)

    Manning, Blaine T; Kearns, Sean M; Bohl, Daniel D; Edmiston, Tori; Sporer, Scott M; Levine, Brett R

    2017-07-01

    Sleep disruption is a common, yet rarely addressed, complaint among patients who have undergone total joint arthroplasty (TJA). This study assessed sleep quality before and after primary TJA. A total of 105 patients who underwent primary total hip arthroplasty (THA) or total knee arthroplasty (TKA) prospectively completed questionnaires during the preoperative, early postoperative, and late postoperative periods. The survey included the Epworth Sleepiness Scale, current sleeping habits, and patient perspectives of sleep quality and duration. In the early postoperative period (4.7±2.0 weeks), patients reported significant increases in sleep disturbance as denoted by increased length of time to fall asleep (P=.006) and mean nightly awakenings (P=.002) compared with the preoperative baseline. At late postoperative follow-up (40.8±19.5 weeks), patients' sleep quality subsequently improved above the preoperative baseline. Approximately 40% of patients tried a new sleeping method postoperatively, the most common being new pillow placement. No significant differences in pre- or postoperative sleeping trends were noted between THA and TKA patients. These findings suggest transient sleep disturbance is common in the early postoperative period, with subsequent improvement by 10-month follow-up after a primary TJA. Given the growing importance of patient satisfaction in health care systems, orthopedic surgeons must manage patients' expectations while working with them to optimize sleep quality after TJA. A multimodal approach with preoperative counseling, early postoperative sleep modifications, and possibly preemptive use of medications may improve transient sleep disturbance among TJA patients. [Orthopedics. 2017; 40(4):e636-e640.]. Copyright 2017, SLACK Incorporated.

  13. Role of fluctuations in the primary energy estimation of cosmic rays

    International Nuclear Information System (INIS)

    Kempa, J.; Malecki, R.

    2008-01-01

    Energy spectrum and chemical composition of primary cosmic ray for energies higher than 1 PeV are obtained mainly from research on the intensity and properties of extensive air showers (EAS). Similar additional information is obtained from research on properties of gamma ray families. A common characteristic of these researches is the fact that we are working in the range of high fluctuation parameters serving us to obtain primary energy spectrum. In this research different probability distributions have been used as well as their convolutions with the power spectrum. The role of the influence of different parameters on measurements of the primary energy spectrum

  14. Institutional total energy case studies

    Energy Technology Data Exchange (ETDEWEB)

    Wulfinghoff, D.

    1979-07-01

    Profiles of three total energy systems in institutional settings are provided in this report. The plants are those of Franciscan Hospital, a 384-bed facility in Rock Island, Illinois; Franklin Foundation Hospital, a 100-bed hospital in Franklin, Louisiana; and the North American Air Defense Command Cheyenne Mountain Complex, a military installation near Colorado Springs, Colorado. The case studies include descriptions of plant components and configurations, operation and maintenance procedures, reliability, relationships to public utilities, staffing, economic efficiency, and factors contributing to success.

  15. Comparative risk assessment of total energy systems

    International Nuclear Information System (INIS)

    Soerensen, B.

    1982-01-01

    The paper discusses a methodology for total impact assessment of energy systems, ideally evaluating all the impacts that a given energy system has on the society in which it is imbedded or into which its introduction is being considered. Impacts from the entire energy conversion chain ('fuel cycle' if the system is fuel-based), including energy storage, transport and transmission, as well as the institutions formed in order to manage the system, should be compared on the basis of the energy service provided. A number of impacts are considered, broadly classified as impacts on satisfaction of biological needs, on health, on environment, on social relations and on the structure of society. Further considerations include impacts related to cost and resilience, and, last but not least, impacts on global relations. The paper discusses a number of published energy studies in the light of the comparative impact assessment methodology outlined above. (author)

  16. A constrained optimization algorithm for total energy minimization in electronic structure calculations

    International Nuclear Information System (INIS)

    Yang Chao; Meza, Juan C.; Wang Linwang

    2006-01-01

    A new direct constrained optimization algorithm for minimizing the Kohn-Sham (KS) total energy functional is presented in this paper. The key ingredients of this algorithm involve projecting the total energy functional into a sequence of subspaces of small dimensions and seeking the minimizer of total energy functional within each subspace. The minimizer of a subspace energy functional not only provides a search direction along which the KS total energy functional decreases but also gives an optimal 'step-length' to move along this search direction. Numerical examples are provided to demonstrate that this new direct constrained optimization algorithm can be more efficient than the self-consistent field (SCF) iteration

  17. The role of hinges in primary total knee replacement.

    Science.gov (United States)

    Gehrke, T; Kendoff, D; Haasper, C

    2014-11-01

    The use of hinged implants in primary total knee replacement (TKR) should be restricted to selected indications and mainly for elderly patients. Potential indications for a rotating hinge or pure hinge implant in primary TKR include: collateral ligament insufficiency, severe varus or valgus deformity (>20°) with necessary relevant soft-tissue release, relevant bone loss including insertions of collateral ligaments, gross flexion-extension gap imbalance, ankylosis, or hyperlaxity. Although data reported in the literature are inconsistent, clinical results depend on implant design, proper technical use, and adequate indications. We present our experience with a specific implant type that we have used for over 30 years and which has given our elderly patients good mid-term results. Because revision of implants with long cemented stems can be very challenging, an effort should be made in the future to use shorter stems in modular versions of hinged implants. ©2014 The British Editorial Society of Bone & Joint Surgery.

  18. Quantifying Blood Loss and Transfusion Risk After Primary vs Conversion Total Hip Arthroplasty.

    Science.gov (United States)

    Newman, Jared M; Webb, Matthew R; Klika, Alison K; Murray, Trevor G; Barsoum, Wael K; Higuera, Carlos A

    2017-06-01

    Primary total hip arthroplasty (THA) and conversion THA may result in substantial blood loss, sometimes necessitating transfusion. Despite the complexities of the latter, both are grouped in the same category for quality assessment and reimbursement. This study's purpose was to compare both blood loss and transfusion risk in primary and conversion THA and identify their associated predictors. A total of 1616 patients who underwent primary and conversion THA at a single hospital from 2009-2013 were reviewed (primary THA = 1575; conversion THA = 41). Demographics, comorbidities, and perioperative data were collected from electronic records. Blood loss was calculated using a validated method. Transfusion triggers were based on standardized criteria. Separate multivariable regression models for blood loss and transfusion were performed. Conversion THA patients were younger (P = .002), had lower age-adjusted Charlson scores (P = .006), longer surgeries (P quantified in the present study and showed consistent results between the 2 metrics. The differences between these procedures should be addressed during quality assurance because conversion THA is associated with higher resource utilization, which is important in the allocation of resources and tiered reimbursement strategies. Copyright © 2017 Elsevier Inc. All rights reserved.

  19. Energy in Croatia 2003. Annual Energy Report

    International Nuclear Information System (INIS)

    2004-11-01

    Reports have kept domestic and international audience continuously informed about the latest relations and developments in the Croatian energy system. Annual report presents all characteristic indicators of the Croatian energy system in 2003, outlines their development over a longer past period, and suggests a future course of development of basic energy system indicators. Total primary energy supply in the Republic of Croatia in 2003 was 5.2 percent higher compared to the previous year. The gross domestic product increased by 4.3 percent over the same period. This means that energy intensity, primary energy supply per unit of gross domestic product, increased by 0.9 percent. Compared to the european Union average Croatian energy intensity was approximately 32 percent higher. Total primary energy production, on the other hand, decreased by 1.1 percent compared to 2002. This means that primary energy self-supply, which fell to 46.4 percent, reached its lowest level to-date in the observed period. The remaining energy needs were met by imports, which increased by 1.7 percent. In the structure of total primary energy supply, decrease has been observed only in energy conversion losses, while all other categories increased. Final energy demand increased by 6.7 percent in 2003, with the levels recorded in different sectors ranging from 2.5 percent in industry to 7.5 and 8 percent in transport and other sectors, respectively. In terms of final energy demand, an increase has been recorded in all energy forms except natural gas, whose consumption showed stagnation. This is due to lower consumption in the energy transformation sector and a significant 9.2 percent increase in its final energy demand. A continuous increase in electricity consumption - which reached 4.8 percent in the observed period - is worth nothing. Energy forms which recorded highest consumption increase levels in 2003 are coal (16 percent) and diesel fuel (15 percent). In contrast to the fast increase in

  20. Solar Total Energy Project (STEP) Performance Analysis of High Temperature Energy Storage Subsystem

    Science.gov (United States)

    Moore, D. M.

    1984-01-01

    The 1982 milestones and lessons learned; performance in 1983; a typical day's operation; collector field performance and thermal losses; and formal testing are highlighted. An initial test that involves characterizing the high temperature storage (hts) subsystem is emphasized. The primary element is on 11,000 gallon storage tank that provides energy to the steam generator during transient solar conditions or extends operating time. Overnight, thermal losses were analyzed. The length of time the system is operated at various levels of cogeneration using stored energy is reviewed.

  1. Evaluation of the Quality of Life and Psychiatric Symptoms of Patients with Primary Coxarthrosis after Total Hip Arthroplasty.

    Science.gov (United States)

    Balik, M S; Hocaoğlu, Ç; Erkut, A; Güvercin, Y; Keskin, D

    2017-01-01

    PURPOSE OF THE STUDY In this study, it was aimed to examine the preoperative and postoperative quality of life and psychiatric symptoms of the patients with primary coxarthrosis after total hip arthroplasty. MATERIAL AND METHODS 150 patients undergone total hip arthroplasty were involved in this study. The socio-demographical data form prepared by the researchers was utilized before and after the operation in order to demonstrate disease-related socio-demographical characteristics of the patient. The Quality of Life Scale Short Form (SF-36), Beck Depression Inventory (BDI), Beck Anxiety Inventory (BAI), Harris Hip Score (HHS) and Visual Analog Scale (VSA) were implemented in the preoperative period and at 6th and 12th week after the operation. RESULTS Of the patients involved in study, 28.7% were male and 71.3% were female. Their mean age was 58.34±11.92 year. While statistically significant differences were found between the preoperative and postoperative periods in terms of physical function, physical role limitation, emotional role limitation, energy, social function, pain, and general health subscales of SF-36, no significant differences were found relating mental health subscale. In BAI, BDI, VAS, and HHS comparison, statistically significant differences were found between the preoperative and postoperative periods, except for BAI. CONCLUSIONS In this study, it was determined that primary coxarthrosis affects significantly the quality of the patients' lives in a negative way and can be accompanied by mental symptoms. After total hip arthroplasty, significant improvement was observed in quality of life, depression and pain scores. Key words: total hip prosthesis, quality of life, mental symptoms.

  2. Comparison of complications in transtrochanteric and anterolateral approaches in primary total hip arthroplasty.

    LENUS (Irish Health Repository)

    Cashman, James P

    2008-11-01

    Three surgical approaches to primary total hip arthroplasty (THA) have been in use since Charnley popularized the transtrochanteric approach. This study was designed to examine the difference in morbidity between the transtrochanteric approach and the anterolateral approach in primary THA. Information on 891 patients who underwent primary THA performed by a single surgeon was collected prospectively between 1998 and 2003 using a modified SF-36 form, preoperatively, intraoperatively, and at 3 months postoperatively. The transtrochanteric group had higher morbidity and more patients who were dissatisfied with their THA. There was a greater range of motion in the anterolateral group.

  3. Total Energy Expenditure in Obese Kuwaiti Primary School Children Assessed by the Doubly-Labeled Water Technique

    Directory of Open Access Journals (Sweden)

    Lena Davidsson

    2016-10-01

    Full Text Available The aim of this pilot study was to assess body composition and total energy expenditure (TEE in 35 obese 7–9 years old Kuwaiti children (18 girls and 17 boys. Total body water (TBW and TEE were assessed by doubly-labeled water technique. TBW was derived from the intercept of the elimination rate of deuterium and TEE from the difference in elimination rates of 18O and deuterium. TBW was used to estimate fat-free mass (FFM, using hydration factors for different ages and gender. Fat mass (FM was calculated as the difference between body weight and FFM. Body weight was not statistically different but TBW was significantly higher (p = 0.018 in boys (44.9% ± 3.3% than girls (42.4% ± 3.0%, while girls had significantly higher estimated FM (45.2 ± 3.9 weight % versus 41.6% ± 4.3%; p = 0.014. TEE was significantly higher in boys (2395 ± 349 kcal/day compared with girls (1978 ± 169 kcal/day; p = 0.001. Estimated physical activity level (PAL was significantly higher in boys; 1.61 ± 0.167 versus 1.51 ± 0.870; p = 0.034. Our results provide the first dataset of TEE in 7–9 years old obese Kuwaiti children and highlight important gender differences to be considered during the development of school based interventions targeted to combat childhood obesity.

  4. Danish survey of acetabular component positioning practice during primary total hip arthroplasty

    DEFF Research Database (Denmark)

    Cotong, Dana; Troelsen, Anders; Husted, Henrik

    2017-01-01

    questions on optimal component positioning, surgical practice patterns in primary THA, indications and surgical techniques used in revision THA. RESULTS: A total of 42 questionnaires were collected, two were excluded, leaving 40 for analyses. 97% of the surgeons reported an optimum cup anteversion within...

  5. Total energy calculations and bonding at interfaces

    International Nuclear Information System (INIS)

    Louie, S.G.

    1984-08-01

    Some of the concepts and theoretical techniques employed in recent ab initio studies of the electronic and structural properties of surfaces and interfaces are discussed. Results of total energy calculations for the 2 x 1 reconstructed diamond (111) surface and for stacking faults in Si are reviewed. 30 refs., 8 figs

  6. High resolution measurements of the He-He total scattering cross section for reduced collision energies between 0.2 and 200

    International Nuclear Information System (INIS)

    Feltgen, R.; Koehler, K.A.; Pauly, H.; Torello, F.; Vehmeyer, H.

    1974-01-01

    The energy dependence of the total scattering cross section is measured for the isotopic systems He 4 -He 4 and He 3 -He 3 using a velocity selected He primary beam and a He target in a scattering chamber maintained at 1.57 deg K. In the low energy region both systems show a pronounced atomic Ramsauer-Townsend effect. At higher energies 13 backward glory extrema in the case of He 4 -He 4 and 10 extrema for He 3 -He 3 are observed. From these extrema the energy dependence of the s-phase shift can be derived. Applying the semiclassical inversion method proposed by Miller it is possible to compute the repulsive potential in the energy range of the measurement

  7. The water footprint of energy consumption: an assessment of water requirements of primary energy carriers

    NARCIS (Netherlands)

    Gerbens-Leenes, P.W.; Hoekstra, A.Y.; Van der Meer, T.H.

    2007-01-01

    Gerbens-Leenes, P.W., Hoekstra, A.Y., Van der Meer, T.H., 2007. The water footprint of energy consumption: an assessment of water requirements of primary energy carriers. In: proceedings ‘First World Water Sustainability-Renewable Energy Congress and Exhibition’. 25-28 November 2007, Maastricht, the

  8. Poynting Theorem, Relativistic Transformation of Total Energy-Momentum and Electromagnetic Energy-Momentum Tensor

    Science.gov (United States)

    Kholmetskii, Alexander; Missevitch, Oleg; Yarman, Tolga

    2016-02-01

    We address to the Poynting theorem for the bound (velocity-dependent) electromagnetic field, and demonstrate that the standard expressions for the electromagnetic energy flux and related field momentum, in general, come into the contradiction with the relativistic transformation of four-vector of total energy-momentum. We show that this inconsistency stems from the incorrect application of Poynting theorem to a system of discrete point-like charges, when the terms of self-interaction in the product {\\varvec{j}} \\cdot {\\varvec{E}} (where the current density {\\varvec{j}} and bound electric field {\\varvec{E}} are generated by the same source charge) are exogenously omitted. Implementing a transformation of the Poynting theorem to the form, where the terms of self-interaction are eliminated via Maxwell equations and vector calculus in a mathematically rigorous way (Kholmetskii et al., Phys Scr 83:055406, 2011), we obtained a novel expression for field momentum, which is fully compatible with the Lorentz transformation for total energy-momentum. The results obtained are discussed along with the novel expression for the electromagnetic energy-momentum tensor.

  9. Energy-analysis of the total nuclear energy cycle based on light water reactors

    International Nuclear Information System (INIS)

    Kistemaker, J.

    1975-01-01

    The energy economy of the total nuclear energy cycle is investigated. Attention is paid to the importance of fossil fuel saving by using nuclear energy. The energy analysis is based on the construction and operation of power plants with an electric output of 1000MWe. Light water moderated reactors with a 2.7 - 3.2% enriched uranium core are considered. Additionally, the whole fuel cycle including ore winning and refining, enrichment and fuel element manufacturing and reprocessing has been taken into account. Neither radioactive waste storage problems nor safety problems related to the nuclear energy cycle and safeguarding have been dealt with, as exhaustive treatments can be found elswhere

  10. Primary energy and greenhouse gases embodied in Australian final consumption: an input-output analysis

    International Nuclear Information System (INIS)

    Lenzen, M.

    1998-01-01

    Input-output modeling of primary energy and greenhouse gas embodiments in goods and services is a useful technique for designing greenhouse gas abatement policies. The present paper describes direct and indirect primary energy and greenhouse gas requirements for a given set of Australian final consumption. It considers sectoral disparities in energy prices, capital formation and international trade flows and it accounts for embodiments in the Gross National Expenditure as well as the Gross Domestic Product. Primary energy and greenhouse gas intensities in terms of MJ/$ and kg CO 2 -e/$ are reported, as well as national balance of primary energy consumption and greenhouse gas emissions. (author)

  11. Dynamic Modelling with "MLE-Energy Dynamic" for Primary School

    Science.gov (United States)

    Giliberti, Enrico; Corni, Federico

    During the recent years simulation and modelling are growing instances in science education. In primary school, however, the main use of software is the simulation, due to the lack of modelling software tools specially designed to fit/accomplish the needs of primary education. In particular primary school teachers need to use simulation in a framework that is both consistent and simple enough to be understandable by children [2]. One of the possible area to approach modelling is about the construction of the concept of energy, in particular for what concerns the relations among substance, potential, power [3]. Following the previous initial research results with this approach [2], and with the static version of the software MLE Energy [1], we suggest the design and the experimentation of a dynamic modelling software—MLE dynamic-capable to represent dynamically the relations occurring when two substance-like quantities exchange energy, modifying their potential. By means of this software the user can graphically choose the dependent and independent variables and leave the other parameters fixed. The software has been initially evaluated, during a course of science education with a group of primary school teachers-to-be, to test the ability of the software to improve teachers' way of thinking in terms of substance-like quantities and their effects (graphical representation of the extensive, intensive variables and their mutual relations); moreover, the software has been tested with a group of primary school teachers, asking their opinion about the software didactical relevance in the class work.

  12. Primary total hip replacement for displaced subcapital fractures of the femur.

    Science.gov (United States)

    Taine, W H; Armour, P C

    1985-03-01

    The management of displaced subcapital fracture of the hip is still controversial because of the high incidence of complications after internal fixation or hemiarthroplasty. To avoid some of these complications we have used primary total hip replacement for independently mobile patients over 65 years of age. A total of 163 cases, operated on over four years, have been reviewed. There were relatively more dislocations after operation for fracture than after total replacement for arthritis, and these were associated with a posterior approach to the hip. Only seven revision operations have been required. Of 57 patients who were interviewed an average of 42 months after replacement, 62% had excellent or good results as assessed by the Harris hip score. All the others had major systemic disease which affected their assessment. This inadequacy of current systems of hip assessment is discussed. It is concluded that total hip replacement is the best management for a selected group of patients with this injury, and that further prospective studies are indicated.

  13. Biomass energy in Jordan, and its potential contribution towards the total energy mix of the Kingdom

    International Nuclear Information System (INIS)

    Al-Dabbas, Moh'd A. F.

    1994-04-01

    An evaluation of Jordan's bio-energy status was carried out. Available sources and the viability of exploitation were studied in order to identify the size of contribution that bio-energy could provide to the total energy mix of the Kingdom. The advantages of biogas technology were discussed, and a general description of Jordan's experience in this field was presented. Data on Jordan' animal, municipal, and agricultural wastes that are available as a potential source of bio-energy was tabulated. The report ascertained the economic feasibility of biogas utilization in Jordan, and concluded that the annual energy production potential from biogas, with only animal wastes being utilized, would amount to 80,000 ton oil equivalent. This amount of energy is equivalent to 2% of Jordan's total energy consumption in 1992. The utilization of biogas from municipal wastes would produce an additional 2.5% of the total energy consumption of Jordan. The annual value of utilizing animal and municipal wastes would reach 23 million Jordanian Dinars (JD). This value would increase to 61.5 million JD with the utilization of human wastes. The investment required for the utilization of bio-energy sources in Amman and its suburbs on the scale of family unit fermenters was estimated to be in the order of a million JD. The size of investment for industrial scale utilization for power generation with an electricity feed to the national grid, would range from 3 to 4 million JD. (A.M.H.). 8 refs., 4 tabs

  14. Measurement of the primary and scatter dose in high energy photon beams

    Energy Technology Data Exchange (ETDEWEB)

    Van der Linden, P M [Catharina Ziekenhuis, Eindhoven (Netherlands). Radiotherapy Dept.; Tiourina, T B; Dries, W

    1995-12-01

    A method is presented to measure the primary and scatter components separately in a water tank using a small cylindrical absorber. Results from this experiment are compared with Monte Carlo calculations. The measurement setup consists of a small cylindrical absorber placed on a central axis of the beam a few centimetres above the radiation detector. Both absorber and detector move along the central axis while absorbed dose is registered. As the primary radiation is fully blocked, only scatter component is measured when a cylindrical absorber is used. Measurements in open fields result in the total absorbed dose being the sum of primary and scatter components. The primary dose component can be derived by substraction. Absorbers with different diameters are used. With decreasing dimensions the relative contribution of the dose due to scatter radiation increases. A steep increase is observed when the range of laterally scattered electrons becomes comparable with the radius of the absorber. Two different Monte Carlo simulations have been performed: with and without secondary electron transport. The data obtained for the former case perfectly agrees with the experiment. The situation where the secondary electron is assumed zero (i.e. local energy deposition) simulates the Cunningham model. Our results show that the Cunningham model predicts lower scatter component under the block edge which can be important for these applications.

  15. Hydrogen Production Costs of Various Primary Energy Sources

    International Nuclear Information System (INIS)

    Choi, Jae Hyuk; Tak, Nam Il; Kim, Yong Hee; Park, Won Seok

    2005-11-01

    Many studies on the economical aspects of hydrogen energy technologies have been conducted with the increase of the technical and socioeconomic importance of the hydrogen energy. However, there is still no research which evaluates the economy of hydrogen production from the primary energy sources in consideration of Korean situations. In this study, the hydrogen production costs of major primary energy sources are compared in consideration of the Korean situations such as feedstock price, electricity rate, and load factor. The evaluation methodology is based on the report of the National Academy of Science (NAS) of U.S. The present study focuses on the possible future technology scenario defined by NAS. The scenario assumes technological improvement that may be achieved if present research and development (R and D) programs are successful. The production costs by the coal and natural gas are 1.1 $/kgH 2 and 1.36 $/kgH 2 , respectively. However, the fossil fuels are susceptible to the price variation depending on the oil and the raw material prices, and the hydrogen production cost also depends on the carbon tax. The economic competitiveness of the renewable energy sources such as the wind, solar, and biomass are relatively low when compared with that of the other energy sources. The estimated hydrogen production costs from the renewable energy sources range from 2.35 $/kgH 2 to 6.03 $/kgH 2 . On the other hand, the production cost by nuclear energy is lower than that of natural gas or coal when the prices of the oil and soft coal are above $50/barrel and 138 $/ton, respectively. Taking into consideration the recent rapid increase of the oil and soft coal prices and the limited fossil resource, the nuclear-hydrogen option appears to be the most economical way in the future

  16. Machine Learning methods in fitting first-principles total energies for substitutionally disordered solid

    Science.gov (United States)

    Gao, Qin; Yao, Sanxi; Widom, Michael

    2015-03-01

    Density functional theory (DFT) provides an accurate and first-principles description of solid structures and total energies. However, it is highly time-consuming to calculate structures with hundreds of atoms in the unit cell and almost not possible to calculate thousands of atoms. We apply and adapt machine learning algorithms, including compressive sensing, support vector regression and artificial neural networks to fit the DFT total energies of substitutionally disordered boron carbide. The nonparametric kernel method is also included in our models. Our fitted total energy model reproduces the DFT energies with prediction error of around 1 meV/atom. The assumptions of these machine learning models and applications of the fitted total energies will also be discussed. Financial support from McWilliams Fellowship and the ONR-MURI under the Grant No. N00014-11-1-0678 is gratefully acknowledged.

  17. Search for ultra high energy primary photons at the Pierre Auger Observatory

    Directory of Open Access Journals (Sweden)

    Colalillo Roberta

    2016-01-01

    Full Text Available The Pierre Auger Observatory, located in Argentina, provides an unprecedented integrated aperture in the search for primary photons with energy above 1017 eV over a large portion of the southern sky. Such photons can be detected in principle via the air showers they initiate at such energies, using the complement of Auger Observatory detectors. We discuss the results obtained in diffuse and directional searches for primary photons in the EeV energy range.

  18. How fast is the growth of Total Cross Section at High Energies?

    CERN Document Server

    Fazal-e-Aleem, M; Sohail-Afzal, Tahir; Ayub-Faridi, M; Qadee-Afzal, M

    2003-01-01

    Relativistic Heavy Ion Collider and Large Hadron Colliders have special agenda for the measurements of the total cross sections at high energies giving us an opportunity to touch cosmic ray energies. Recent analyses of the cosmic ray data together with earlier experimental measurements at ISR and SPS gives us an insight about the behaviour of this important parameter at asymptotic energies. We will study the growth of total cross section at high energies in the light of various theoretical approaches with special reference to measurements at RHIC and LHC.

  19. Ecological total-factor energy efficiency of regions in China

    International Nuclear Information System (INIS)

    Li Lanbing; Hu Jinli

    2012-01-01

    Most existing energy efficiency indices are computed without taking into account undesirable outputs such as CO 2 and SO 2 emissions. This paper computes the ecological total-factor energy efficiency (ETFEE) of 30 regions in China for the period 2005–2009 through the slack-based model (SBM) with undesirable outputs. We calculate the ETFEE index by comparing the target energy input obtained from SBM with undesirable outputs to the actual energy input. Findings show that China's regional ETFEE still remains a low level of around 0.600 and regional energy efficiency is overestimated by more than 0.100 when not looking at environmental impacts. China's regional energy efficiency is extremely unbalanced: the east area ranks first with the highest ETFEE of above 0.700, the northeast and central areas follow, and the west area has the lowest ETFEE of less than 0.500. A monotone increasing relation exists between the area's ETFEE and China's per capita GDP. The truncated regression model shows that the ratio of R and D expenditure to GDP and the degree of foreign dependence have positive impacts, whereas the ratio of the secondary industry to GDP and the ratio of government subsidies for industrial pollution treatment to GDP have negative effects, on the ETFEE. - Highlights: ► Most energy efficiency indices ignore undesirable outputs such as CO 2 and SO 2 emissions. ► The ecological total-factor energy efficiency (ETFEE) is computed by slack-based model (SBM). ► The datasets contains 30 regions in China for the period 2005–2009. ► China's regional energy efficiency is extremely unbalanced. ► A monotone increasing relation exists between ETFEE and per capita GDP.

  20. Economic analysis model for total energy and economic systems

    International Nuclear Information System (INIS)

    Shoji, Katsuhiko; Yasukawa, Shigeru; Sato, Osamu

    1980-09-01

    This report describes framing an economic analysis model developed as a tool of total energy systems. To prospect and analyze future energy systems, it is important to analyze the relation between energy system and economic structure. We prepared an economic analysis model which was suited for this purpose. Our model marks that we can analyze in more detail energy related matters than other economic ones, and can forecast long-term economic progress rather than short-term economic fluctuation. From view point of economics, our model is longterm multi-sectoral economic analysis model of open Leontief type. Our model gave us appropriate results for fitting test and forecasting estimation. (author)

  1. Primary Total Knee Replacement: Is Suction a Portal of Infection?

    Science.gov (United States)

    Budnar, Vijaya M; Amirfeyz, Rouin; Ng, Michael; Bannister, Gordon C; Blom, Ashley W

    2009-01-01

    INTRODUCTION Pulsed lavage during a total knee replacement usually leaves a pool of fluid on the surgical drapes. It is common practice to suck away this fluid using the same suction device used intra-operatively. This could be a cause of direct wound contamination. We hypothesised that bacteria contaminate fluid that collects around the foot in total knee replacement surgery and that suction equipment could be a portal of contamination. We also hypothesised that bacterial count in the fluid is lower if chlorhexidine, rather than saline, is used in the pulsed lavage. PATIENTS AND METHODS Forty patients undergoing primary total knee replacement were divided into two groups. The first group had pulsed lavage with normal saline and the second with 0.05% chlorhexidine. RESULTS At the end of the operation, 20 ml of fluid, pooled on the surgical drapes was aspirated and cultured for bacterial growth. None of the fluid samples showed bacterial growth. CONCLUSIONS Suction device used peri-operatively during knee replacement is unlikely to be a cause of wound contamination. Pulsed lavage with normal saline is as effective as lavage with chlorhexidine. PMID:19335972

  2. Risk factors for revision of primary total hip arthroplasty: a systematic review

    Directory of Open Access Journals (Sweden)

    Prokopetz Julian JZ

    2012-12-01

    Full Text Available Abstract Background Numerous papers have been published examining risk factors for revision of primary total hip arthroplasty (THA, but there have been no comprehensive systematic literature reviews that summarize the most recent findings across a broad range of potential predictors. Methods We performed a PubMed search for papers published between January, 2000 and November, 2010 that provided data on risk factors for revision of primary THA. We collected data on revision for any reason, as well as on revision for aseptic loosening, infection, or dislocation. For each risk factor that was examined in at least three papers, we summarize the number and direction of statistically significant associations reported. Results Eighty-six papers were included in our review. Factors found to be associated with revision included younger age, greater comorbidity, a diagnosis of avascular necrosis (AVN as compared to osteoarthritis (OA, low surgeon volume, and larger femoral head size. Male sex was associated with revision due to aseptic loosening and infection. Longer operating time was associated with revision due to infection. Smaller femoral head size was associated with revision due to dislocation. Conclusions This systematic review of literature published between 2000 and 2010 identified a range of demographic, clinical, surgical, implant, and provider variables associated with the risk of revision following primary THA. These findings can inform discussions between surgeons and patients relating to the risks and benefits of undergoing total hip arthroplasty.

  3. Energy statistical data. Europe

    International Nuclear Information System (INIS)

    2002-04-01

    This report summarizes in a series of tables the key energy data of 1999 for 9 European countries (Germany, Belgium, Denmark, Spain, France, Italy, Netherlands, UK, Sweden). Data concern: the energy intensity, the share of renewable energy sources in the total primary consumption, the structure of power production, the CO 2 emissions and their structure, and the end-use, primary consumption and energy prices per energy source. (J.S.)

  4. Contribution to the development of a primary standard for high energy neutron beams

    International Nuclear Information System (INIS)

    Mancaux, M.

    1983-12-01

    A tissue equivalent calorimeter, made of Shonka A-150 plastic, has been constructed in order to create a primary standard for high energy neutrons and to establish a calibration procedure for ionization chambers used in neutrontherapy. After a detailed description of the calorimeter and the associated measuring system, the preliminary tests are presented, in particular, the evolution of the response as a function of accumulated dose. The measurements of the total absorbed dose (n + γ) by calorimetry in a neutron beam, in order to determine chambers' calibration factors in terms of absorbed dose to A-150 plastic, have been performed at the Neutrontherapy Unit of the Centre Hospitalier Regional d'Orleans. The uncertainty in the determination of the total absorbed dose to the tissu equivalent material using the new procedure is 3% lower than that obtained with the usual procedure, derived from an exposure calibration [fr

  5. Thermodynamics of the living organisms. Allometric relationship between the total metabolic energy, chemical energy and body temperature in mammals

    Science.gov (United States)

    Atanasov, Atanas Todorov

    2017-11-01

    The study present relationship between the total metabolic energy (ETME(c), J) derived as a function of body chemical energy (Gchem, J) and absolute temperature (Tb, K) in mammals: ETME(c) =Gchem (Tb/Tn). In formula the temperature Tn =2.73K appears normalization temperature. The calculated total metabolic energy ETME(c) differs negligible from the total metabolic energy ETME(J), received as a product between the basal metabolic rate (Pm, J/s) and the lifespan (Tls, s) of mammals: ETME = Pm×Tls. The physical nature and biological mean of the normalization temperature (Tn, K) is unclear. It is made the hypothesis that the kTn energy (where k= 1.3806×10-23 J/K -Boltzmann constant) presents energy of excitation states (modes) in biomolecules and body structures that could be in equilibrium with chemical energy accumulated in body. This means that the accumulated chemical energy allows trough all body molecules and structures to propagate excitations states with kTn energy with wavelength in the rage of width of biological membranes. The accumulated in biomolecules chemical energy maintains spread of the excited states through biomolecules without loss of energy.

  6. The Use of Energy in Malaysia: Tracing Energy Flows from Primary Source to End Use

    OpenAIRE

    Chinhao Chong; Weidou Ni; Linwei Ma; Pei Liu; Zheng Li

    2015-01-01

    Malaysia is a rapidly developing country in Southeast Asia that aims to achieve high-income country status by 2020; its economic growth is highly dependent on its abundant energy resources, especially natural gas and crude oil. In this paper, a complete picture of Malaysia’s energy use from primary source to end use is presented by mapping a Sankey diagram of Malaysia’s energy flows, together with ongoing trends analysis of the main factors influencing the energy flows. The results indicate t...

  7. Total elbow arthroplasty in primary osteoarthritis of the elbow.

    Science.gov (United States)

    Kozak, T K; Adams, R A; Morrey, B F

    1998-10-01

    Primary osteoarthritis of the elbow is an infrequent condition typically managed by some form of debridement. There is no comment in the literature regarding prosthetic replacement for this condition. We report 5 patients (mean age, 68), with a minimum assessment of 3 years (range, 37-125 years) after total elbow arthroplasty. Complications in 4 patients included subluxation, fracture of a humeral component with particulate synovitis, heterotopic ossification, recurrent osteophyte formation, and transient ulnar neuropathy. Although revision was required in 2 of the 5, currently all experience had satisfactory outcomes. While replacement has proven ultimately to be a successful option for this high-demand patient group because of the high complication rate, we do not recommend replacement unless alternate operative options are deemed unacceptable.

  8. Blood Loss and Transfusion After Topical Tranexamic Acid Administration in Primary Total Knee Arthroplasty.

    Science.gov (United States)

    Wang, Hao; Shen, Bin; Zeng, Yi

    2015-11-01

    There has been much debate and controversy about the safety and efficacy of the topical use of tranexamic acid in primary total knee arthroplasty (TKA). The purpose of this study was to perform a meta-analysis to evaluate whether there is less blood loss and lower rates of transfusion after topical tranexamic acid administration in primary TKA. A systematic review of the electronic databases PubMed, CENTRAL, Web of Science, and Embase was undertaken. All randomized, controlled trials and prospective cohort studies evaluating the effectiveness of topical tranexamic acid during primary TKA were included. The focus of the analysis was on the outcomes of blood loss results, transfusion rate, and thromboembolic complications. Subgroup analysis was performed when possible. Of 387 studies identified, 16 comprising 1421 patients (1481 knees) were eligible for data extraction and meta-analysis. This study indicated that when compared with the control group, topical application of tranexamic acid significantly reduced total drain output (mean difference, -227.20; 95% confidence interval, -347.11 to -107.30; Ptranexamic acid in primary TKA. Furthermore, the currently available evidence does not support an increased risk of deep venous thrombosis or pulmonary embolism due to tranexamic acid administration. Topical tranexamic acid was effective for reducing postoperative blood loss and transfusion requirements without increasing the prevalence of thromboembolic complications. Copyright 2015, SLACK Incorporated.

  9. Primary energy consumption of the dwelling with solar hot water system and biomass boiler

    International Nuclear Information System (INIS)

    Berković-Šubić, Mihaela; Rauch, Martina; Dović, Damir; Andrassy, Mladen

    2014-01-01

    Highlights: • Methodology for determing delivered and primary energy is developed. • Conventional and solar hot water system are analyzed. • Influence of system components, heat losses and energy consumption is explored. • Savings when using solar system in delivered energy is 30% and in primary 75%. • Dwelling with higher Q H,nd has 60% shorter payback period. - Abstract: This paper presents a new methodology, based on the energy performance of buildings Directive related European norms. It is developed to overcome ambiguities and incompleteness of these standards in determining the delivered and primary energy. The available procedures from the present “Algorithm for determining the energy demands and efficiency of technical systems in buildings”, normally used for energy performance certification of buildings, also allow detailed analyzes of the influence of particular system components on the overall system energy efficiency. The calculation example is given for a Croatian reference dwelling, equipped with a solar hot water system, backed up with a biomass boiler for space heating and domestic hot water purposes as a part of the dwelling energy performance certification. Calculations were performed for two cases corresponding to different levels of the dwelling thermal insulation with an appropriate heating system capacity, in order to investigate the influence of the building heat losses on the system design and energy consumption. The results are compared against those obtained for the conventional system with a gas boiler in terms of the primary energy consumption as well as of investment and operating costs. These results indicate great reduction in both delivered and primary energy consumption when a solar system with biomass boiler is used instead of the conventional one. Higher savings are obtained in the case of the dwelling with higher energy need for space heating. Such dwellings also have a shorter payback period than the ones with

  10. Autograft reconstructions for bone defects in primary total knee replacement in severe varus knees

    Directory of Open Access Journals (Sweden)

    Yatinder Kharbanda

    2014-01-01

    Full Text Available Background: Large posteromedial defects encountered in severe varus knees during primary total knee arthroplasty can be treated by cementoplasty, structural bone grafts or metallic wedges. The option is selected depending upon the size of the defect. We studied the outcome of autograft (structural and impaction bone grafting reconstruction of medial tibial bone defects encountered during primary total knee replacement in severe varus knees. Materials and Methods: Out of 675 primary varus knees operated, bone defects in proximal tibia were encountered in 54 knees. Posteromedial defects involving 25-40% of the tibial condyle cut surface and measuring more than 5 mm in depth were grafted using a structural graft obtained from cut distal femur or proximal tibia in 48 knees. For larger, peripheral uncontained vertical defects in six cases, measuring >25 mm in depth and involving >40% cut surface of proximal tibial condyle, impaction bone grafting with a mesh support was used. Results: Bone grafts incorporated in 54 knees in 6 months. There was no graft collapse or stress fractures, loosening or nonunion. The average followup period was 7.8 years (range 5-10 years. We observed an average postoperative increase in the Knee Society Score from 40 to 90 points. There was improvement in the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC scores in terms of pain, stiffness and physical function during activities of daily living. Conclusion: Bone grafting for defects in primary total knee is justified as it is biological, available then and is cost effective besides preserving bone stock for future revisions. Structural grafts should be used in defects >5 mm deep and involving 25-40% of the cut proximal tibial condyle surface. For larger peripheral vertical defects, impaction bone grafting contained in a mesh should be done.

  11. Use of tranexamic acid in primary total knee replacement: effects on perioperative blood loss.

    Science.gov (United States)

    Volquind, Daniel; Zardo, Remi Antônio; Winkler, Bruno Costamilan; Londero, Bruno Bertagnolli; Zanelatto, Natália; Leichtweis, Gisele Perondi

    2016-01-01

    The use of tranexamic acid in primary total knee replacement surgeries has been the subject of constant study. The strategies to reduce bleeding are aimed at reducing the need for blood transfusion due to the risks involved. In this study we evaluated the use of tranexamic acid in reducing bleeding, need for blood transfusion, and prevalence of postoperative deep vein thrombosis in primary total knee replacement. 62 patients undergoing primary total knee replacement were enrolled in the study, from June 2012 to May 2013, and randomized to receive a single dose of 2.5g of intravenous tranexamic acid (Group TA) or saline (Group GP), 5min before opening the pneumatic tourniquet, respectively. Hemoglobin, hematocrit, and blood loss were recorded 24h after surgery. Deep vein thrombosis was investigated during patient's hospitalization and 15 and 30 days after surgery in review visits. There was no demographic difference between groups. Group TA had 13.89% decreased hematocrit (p=0.925) compared to placebo. Group TA had a decrease of 12.28% (p=0.898) in hemoglobin compared to Group GP. Group TA had a mean decrease of 187.35mL in blood loss (25.32%) compared to group GP (p=0.027). The number of blood transfusions was higher in Group GP (p=0.078). Thromboembolic events were not seen in this study. Tranexamic acid reduced postoperative bleeding without promoting thromboembolic events. Copyright © 2015 Sociedade Brasileira de Anestesiologia. Published by Elsevier Editora Ltda. All rights reserved.

  12. Dislocation of primary total hip arthroplasty and the risk of redislocation.

    LENUS (Irish Health Repository)

    Brennan, Stephen A

    2012-09-01

    6554 primary total hip arthroplasties were reviewed. Risk factors for dislocation were analysed to assess which were important in terms of predicting recurrent instability. The patients risk of having a second dislocation was independently associated with the surgical approach adopted (p = 0.03) and the time to first dislocation from the primary hip replacement (p = 0.002). Early dislocators whose surgery was performed through an anterolateral approach had less recurrence than late dislocators through a posterior or transtrochanteric approach. None of the other risk factors including head size (p = 0.59), modularity (p = 0.54), mechanism of dislocation (p = 0.23), leg length discrepancy (p = 0.69) and acetabular inclination (p = 0.31) were influential. The use of an abduction brace was not useful in preventing a further dislocation with 69.2% of those braced re-dislocating compared to 68.5% who were not braced (p = 0.96).

  13. Hydrogen Production Costs of Various Primary Energy Sources

    International Nuclear Information System (INIS)

    Choi, Jae Hyuk; Tak, Nam Il; Kim, Yong Hee; Park, Won Seok

    2005-01-01

    The limited resource and environmental impacts of fossil fuels are becoming more and more serious problems in the world. Consequently, hydrogen is in the limelight as a future alternative energy due to its clean combustion and inexhaustibility and a transition from the traditional fossil fuel system to a hydrogen-based energy system is under considerations. Several countries are already gearing the industries to the hydrogen economy to cope with the limitations of the current fossil fuels. Unfortunately, hydrogen has to be chemically separated from the hydrogen compounds in nature such as water by using some energy sources. In this paper, the hydrogen production costs of major primary energy sources are compared in consideration of the Korean situations. The evaluation methodology is based on the report of the National Academy of Science (NAS) of U.S

  14. Environment-adjusted total-factor energy efficiency of Taiwan's service sectors

    International Nuclear Information System (INIS)

    Fang, Chin-Yi; Hu, Jin-Li; Lou, Tze-Kai

    2013-01-01

    This study computes the pure technical efficiency (PTE) and energy-saving target of Taiwan's service sectors during 2001–2008 by using the input-oriented data envelopment analysis (DEA) approach with the assumption of a variable returns-to-scale (VRS) situation. This paper further investigates the effects of industry characteristics on the energy-saving target by applying the four-stage DEA proposed by Fried et al. (1999). We also calculate the pre-adjusted and environment-adjusted total-factor energy efficiency (TFEE) scores in these service sectors. There are three inputs (labor, capital stock, and energy consumption) and a single output (real GDP) in the DEA model. The most energy efficient service sector is finance, insurance and real estate, which has an average TFEE of 0.994 and an environment-adjusted TFEE (EATFEE) of 0.807. The study utilizes the panel-data, random-effects Tobit regression model with the energy-saving target (EST) as the dependent variable. Those service industries with a larger GDP output have greater excess use of energy. The capital–labor ratio has a significantly positive effect while the time trend variable has a significantly negative impact on the EST, suggesting that future new capital investment should also be accompanied with energy-saving technology in the service sectors. - Highlights: • The technical efficiency and energy-saving target of service sectors are assessed. • The pre-adjusted and environment-adjusted total-factor energy efficiency scores in services are assessed. • The industrial characteristic differences are examined by the panel-data, random-effects Tobit regression model. • Labor, capital, and energy and an output (GDP) are included in the DEA model. • Future new capital investment should also be accompanied with energy-saving technology in the service sectors

  15. Total Corporate social responsibility report 2004. Sharing our energy; TOTAL rapport societal and environnemental 2004. Notre energie en partage

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2005-05-15

    This document presents the social and environmental activities of the group Total for the year 2004. It provides information on the ethical aspects of the governance, the industrial security, the environmental policy, the public health and the occupational safety, the social liability and the economical and social impact of the group activities in the local development, the contribution to the climatic change fight and the development of other energy sources. (A.L.B.)

  16. Should All Patients Be Included in Alternative Payment Models for Primary Total Hip Arthroplasty and Total Knee Arthroplasty?

    Science.gov (United States)

    Rozell, Joshua C; Courtney, Paul M; Dattilo, Jonathan R; Wu, Chia H; Lee, Gwo-Chin

    2016-09-01

    Alternative payment models in total joint replacement incentivize cost effective health care delivery and reward reductions in length of stay (LOS), complications, and readmissions. If not adjusted for patient comorbidities, they may encourage restrictive access to health care. We prospectively evaluated 802 consecutive primary total hip arthroplasty and total knee arthroplasty patients evaluating comorbidities associated with increased LOS and readmissions. During this 9-month period, 115 patients (14.3%) required hospitalization >3 days and 16 (1.99%) were readmitted within 90 days. Univariate analysis demonstrated that preoperative narcotic use, heart failure, stroke, chronic kidney disease (CKD), chronic obstructive pulmonary disease (COPD), and liver disease were more likely to require hospitalization >3 days. In multivariate analysis, CKD and COPD were independent risk factors for LOS >3 days. A Charlson comorbidity index >5 points was associated with increased LOS and readmissions. Patients with CKD, COPD, and Charlson comorbidity index >5 points should not be included in alternative payment model for THA and TKA. Copyright © 2016 Elsevier Inc. All rights reserved.

  17. Parameterization of α-nucleus total reaction cross section at intermediate energies

    International Nuclear Information System (INIS)

    Alvi, M A; Abdulmomen, M A

    2008-01-01

    Applying a Coulomb correction factor to the Glauber model we have derived a closed expression for α-nucleus total reaction cross section, σ R . Under the approximation of rigid projectile model, the elastic S-matrix element S el (b) is evaluated from the phenomenological N-α amplitude and a Gaussian fit to the Helm's model form factor. Excellent agreements with the experimental data have been achieved by performing two-parameter fits to the α-nucleus σ R data in the energy range about 75 to 193 MeV. One of the parameters was found to be energy independent while the other, as expected, shows the energy dependence similar to that of N-α total cross section.

  18. Research on the decomposition model for China’s National Renewable Energy total target

    International Nuclear Information System (INIS)

    Liu, Zhen; Shi, Yuren; Yan, Jianming; Ou, Xunmin; Lieu, Jenny

    2012-01-01

    It is crucial that China’s renewable energy national target in 2020 is effectively decomposed into respective period targets at the provincial level. In order to resolve problems arising from combining the national and local renewable energy development plan, a total target and period target decomposition model of renewable energy is proposed which considers the resource distribution and energy consumption of different provinces as well as the development characteristics of various renewable energy industries. In the model, the total proposed target is comprised of three shares: basic share, fixed share and floating share target. The target distributed for each province is then determined by the preference relation. That is, when total renewable energy target is distributed, the central government is more concerned about resources potential or energy consumption. Additionally, the growth models for various renewable energy industries are presented, and the period targets of renewable energy in various provinces are proposed in line with regional economic development targets. In order to verify whether the energy target can be achieved, only wind power, solar power, and hydropower are considered in this study. To convenient to assess the performance of local government, the two year period is chosen as an evaluation cycle in the paper. The renewable energy targets per two-year period for each province are calculated based on the overall national renewable energy target, energy requirements and resources distribution. Setting provincial period targets will help policy makers to better implement and supervise the overall renewable energy plan. - Highlights: It is very importance that the national target of renewable energy in 2020 can be effectively decomposed into the stages target of various province. In order to resolve the relation the plan between the national and local renewable energy development planning, a total target and phase target decomposition model

  19. Primary energy savings using heat storage for biomass heating systems

    Directory of Open Access Journals (Sweden)

    Mitrović Dejan M.

    2012-01-01

    Full Text Available District heating is an efficient way to provide heat to residential, tertiary and industrial users. The heat storage unit is an insulated water tank that absorbs surplus heat from the boiler. The stored heat in the heat storage unit makes it possible to heat even when the boiler is not working, thus increasing the heating efficiency. In order to save primary energy (fuel, the boiler operates on nominal load every time it is in operation (for the purpose of this research. The aim of this paper is to analyze the water temperature variation in the heat storage, depending on the heat load and the heat storage volume. Heat load is calculated for three reference days, with average daily temperatures from -5 to 5°C. The primary energy savings are also calculated for those days in the case of using heat storage in district heating.[Projekat Ministarstva nauke Republike Srbije, br. TR 33051: The concept of sustainable energy supply of settlements with energy efficient buildings

  20. Status of geothermal energy amongst the world's energy sources

    International Nuclear Information System (INIS)

    Fridleifsson, I.B.

    2003-01-01

    The world primary energy consumption is about 400 EJ/year, mostly provided by fossil fuels (80%), The renewables collectively provide 14% of the primary energy, in the form of traditional biomass (10%), large (>10 MW) hydropower stations (2%), and the ''new renewables''(2%). Nuclear energy provides 6%. The World Energy Council expects the world primary energy consumption to have grown by 50-275% in 2050, depending on different scenarios. The renewable energy sources are expected to provide 20-40% of the primary energy in 2050 and 30-80% in 2100. The technical potential of the renewables is estimated at 7600 EJ/year, and thus certainly sufficiently large to meet future world energy requirements. Of the total electricity production from renewables of 2826 TWh in 1998, 92% came from hydropower, 5.5% from biomass, 1.6% from geothermal and 0.6% from wind. Solar electricity contributed 0.05% and tidal 0.02%. The electricity cost is 2-10 UScents/kWh for geothermal and hydro, 5-13 UScents/kWh for wind, 5-15 UScents/kWh for biomass, 25-125 UScents/kWh for solar photovoltaic and 12-18 UScents/kWh for solar thermal electricity. Biomass constitutes 93% of the total direct heat production from renewables, geothermal 5%, and solar heating 2%. Heat production from renewables is commercially competitive with conventional energy sources. Direct heat from biomass costs 1-5 UScents/kWh, geothermal 0.5-5 UScents/kWh, and solar heating 3-20 UScents/kWh. (author)

  1. Lawsuits After Primary and Revision Total Hip Arthroplasties: A Malpractice Claims Analysis.

    Science.gov (United States)

    Patterson, Diana C; Grelsamer, Ronald P; Bronson, Michael J; Moucha, Calin S

    2017-10-01

    As the prevalence of total hip arthroplasty (THA) expands, so too will complications and patient dissatisfaction. The goal of this study was to identify the common etiologies of malpractice suits and costs of claims after primary and revision THAs. Analysis of 115 malpractice claims filed for alleged neglectful primary and revision THA surgeries by orthopedic surgeons insured by a large New York state malpractice carrier between 1983 and 2011. The incidence of malpractice claims filed for negligent THA procedures is only 0.15% per year in our population. In primary cases, nerve injury ("foot drop") was the most frequent allegation with 27 claims. Negligent surgery causing dislocation was alleged in 18 and leg length discrepancy in 14. Medical complications were also reported, including 3 thromboembolic events and 6 deaths. In revision cases, dislocation and infection were the most common source of suits. The average indemnity payment was $386,153 and the largest single settlement was $4.1 million for an arterial injury resulting in amputation after a primary hip replacement. The average litigation cost to the insurer was $61,833. Nerve injury, dislocation, and leg length discrepancy are the most common reason for malpractice after primary THA. Orthopedic surgeons should continue to focus on minimizing the occurrence of these complications while adequately incorporating details about the risks and limitations of surgery into their preoperative education. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. Impact of dietary fiber energy on the calculation of food total energy value in the Brazilian Food Composition Database.

    Science.gov (United States)

    Menezes, Elizabete Wenzel de; Grande, Fernanda; Giuntini, Eliana Bistriche; Lopes, Tássia do Vale Cardoso; Dan, Milana Cara Tanasov; Prado, Samira Bernardino Ramos do; Franco, Bernadette Dora Gombossy de Melo; Charrondière, U Ruth; Lajolo, Franco Maria

    2016-02-15

    Dietary fiber (DF) contributes to the energy value of foods and including it in the calculation of total food energy has been recommended for food composition databases. The present study aimed to investigate the impact of including energy provided by the DF fermentation in the calculation of food energy. Total energy values of 1753 foods from the Brazilian Food Composition Database were calculated with or without the inclusion of DF energy. The energy values were compared, through the use of percentage difference (D%), in individual foods and in daily menus. Appreciable energy D% (⩾10) was observed in 321 foods, mainly in the group of vegetables, legumes and fruits. However, in the Brazilian typical menus containing foods from all groups, only D%foods, when individually considered. Copyright © 2015 Elsevier Ltd. All rights reserved.

  3. Bipolar sealer not superior to standard electrocautery in primary total hip arthroplasty: a meta-analysis.

    Science.gov (United States)

    Yang, Yang; Zhang, Li-Chao; Xu, Fei; Li, Jia; Lv, Yong-Ming

    2014-10-10

    To assess whether bipolar sealer has advantages over standard electrocautery in primary total hip arthroplasty (THA). All studies published through November 2013 were systematically searched in PubMed, Embase, ScienceDirect, The Cochrane Library, and other databases. Relevant journals or conference proceedings were searched manually. Only randomized controlled trials were included. Two independent reviewers identified and assessed the literature. Mean difference in blood loss and risk ratios of transfusion rates and of complication rates in the bipolar sealer group versus the standard electrocautery group were calculated. The meta-analysis was conducted using RevMan 5.1 software. Five studies were included, with a total sample size of 559 patients. The use of bipolar sealer did not significantly reduce intraoperative blood loss, hemoglobin drop, hospital stay, and operative time. There were no significant differences in need for transfusion and the incidence of infection between the study groups. The available evidence suggests that the use of bipolar sealer was not superior to standard electrocautery in patients undergoing primary THA. The use of bipolar sealer is not recommended in primary THA.

  4. Energy in Croatia 2012, Annual Energy Report

    International Nuclear Information System (INIS)

    2013-01-01

    With the twenty-first edition of the Review Energy in Croatia, Ministry of Economy, Labour and Entrepreneurship continues the practice of informing domestic and foreign public on relations and trends within the Croatian energy sector. This Review gives, in a recognizable and comprehensible way, data and characteristic values relevant to the Croatian energy sector, providing an overview on energy production and consumption at all levels. There is a detailed analysis of the trends present in the energy sector as well as a number of information on capacities, reserves, prices and energy balances for crude oil, all petroleum products, natural gas, electricity, heat energy, coal and renewable energy sources. The Review also brings the main economic and financial indicators, data on air pollutant emissions and main energy efficiancy indicators. It also gives the ODEX energy efficiency index, which is determined according to the methodology used in the European Union. This indicator monitors the energy efficiancy trends over a period of time in the sectors of industry, transport, households and in total consumption. Finally, the Review brings the energy balances of the Republic of Croatia for the years 2011 and 2012, made following the EUROSTAT and IEA methodologies. In 2012 total energy demand in Croatia was 4.7 percent lower than the year before. At the same time, gross domestic product fell by 2 percent, which resulted in a decrease in a total primary energy supply intensity by 2.8 percent. When compared to the average energy intensity level in the EU (EU27), the energy intensity in Croatia was 6.9 percent higher. The primary energy production in 2012 decreased by 5.6 compared to the previous year. Also, due to hydrological situation the hydropower utilization grew by 6.7 percent. The energy from renewable sources increased by 29.8 percent and the energy from fuel wood increased by 5.6 percent. The production of crude oil in 2012 decreased by 9.7 percent and of natural

  5. The Impact of Medical Comorbidities on Primary Total Knee Arthroplasty Reimbursements.

    Science.gov (United States)

    Sabeh, Karim G; Rosas, Samuel; Buller, Leonard T; Freiberg, Andrew A; Emory, Cynthia L; Roche, Martin W

    2018-05-23

    Medical comorbidities have been shown to cause an increase in peri-and postoperative complications following total knee arthroplasty (TKA). However, the increase in cost associated with these complications has yet to be determined. Factors that influence cost have been of great interest particularly after the initiation of bundled payment initiatives. In this study, we present and quantify the influence of common medical comorbidities on the cost of care in patients undergoing primary TKA. A retrospective level of evidence III study was performed using the PearlDiver supercomputer to identify patients who underwent primary TKA between 2007 and 2015. Patients were stratified by medical comorbidities and compared using analysis of variance for reimbursements for the day of surgery and over 90 days postoperatively. A cohort of 137,073 US patients was identified as having undergone primary TKA between 2007 and 2015. The mean entire episode-of-care reimbursement was $23,701 (range: $21,294-26,299; standard deviation [SD] $2,611). The highest reimbursements were seen in patients with chronic obstructive pulmonary disease (mean $26,299; SD $3,030), hepatitis C (mean $25,662; SD $2,766), morbid obesity (mean $25,450; SD $2,154), chronic kidney disease (mean $25,131, $3,361), and cirrhosis (mean $24,890; SD $2,547). Medical comorbidities significantly impact reimbursements, and therefore cost, after primary TKA. Comprehensive preoperative optimization for patients with medical comorbidities undergoing TKA is highly recommended and may reduce perioperative complications, improve patient outcome, and ultimately reduce cost. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  6. Correlation of high energy muons with primary composition in extensive air shower

    Science.gov (United States)

    Chou, C.; Higashi, S.; Hiraoka, N.; Ozaki, S.; Sato, T.; Suwada, T.; Takahasi, T.; Umeda, H.

    1985-01-01

    An experimental investigation of high energy muons above 200 GeV in extensive air showers has been made for studying high energy interaction and primary composition of cosmic rays of energies in the range 10 to the 14th power approx. 10 to the 15th power eV. The muon energies are estimated from the burst sizes initiated by the muons in the rock, which are measured by four layers of proportional counters, each of area 5 x 2.6 sq m, placed at 30 m.w.e. deep, Funasaka tunnel vertically below the air shower array. These results are compared with Monte Carlo simulations based on the scaling model and the fireball model for two primary compositions, all proton and mixed.

  7. Energy efficiency improvement: A strong driver for Total operations and R and D

    Energy Technology Data Exchange (ETDEWEB)

    Garnaud, Frederic; Rocher, Anne

    2010-09-15

    Total has implemented an energy efficiency action plan for both producing fields and new projects linked to a dedicated R and D program. The Energy efficiency assessment methodology is described, with an example: base line of the current situation, energy efficiency plan, contribution to best practices at corporate level. A methodology to assess the energy efficiency of a new development has been defined and implemented within Total. This methodology as well as related indicators is presented. Examples of R and D results dedicated to improve energy efficiency in two major areas of future developments are given: sour gas production and deep offshore field architecture.

  8. Performance of primary repair on colon injuries sustained from low-versus high-energy projectiles.

    Science.gov (United States)

    Lazovic, Ranko; Radojevic, Nemanja; Curovic, Ivana

    2016-04-01

    Among various reasons, colon injuries may be caused by low- or high-energy firearm bullets, with the latter producing a temporary cavitation phenomenon. The available treatment options include primary repair and two-stage management, but recent studies have shown that primary repair can be widely used with a high success rate. This paper investigates the differences in performance of primary repair on these two types of colon injuries. Two groups of patients who sustained colon injuries due to single gunshot wounds, were retrospectively categorized based on the type of bullet. Primary colon repair was performed in all patients selected based on the inclusion and exclusion criteria (Stone and Fabian's criteria). An almost absolute homogeneity was attained among the groups in terms of age, latent time before surgery, and four trauma indexes. Only one patient from the low-energy firearm projectile group (4%) developed a postsurgical complication versus nine patients (25.8%) from the high-energy group, showing statistically significant difference (p = 0.03). These nine patients experienced the following postsurgical complications: pneumonia, abscess, fistula, suture leakage, and one multiorgan failure with sepsis. Previous studies concluded that one-stage primary repair is the best treatment option for colon injuries. However, terminal ballistics testing determined the projectile's path through the body and revealed that low-energy projectiles caused considerably lesser damage than their high-energy counterparts. Primary colon repair must be performed definitely for low-energy short firearm injuries but very carefully for high-energy injuries. Given these findings, we suggest that the treatment option should be determined based not only on the bullet type alone but also on other clinical findings. Copyright © 2016 Elsevier Ltd and Faculty of Forensic and Legal Medicine. All rights reserved.

  9. 6,7Li + 28Si total reaction cross sections at near barrier energies

    International Nuclear Information System (INIS)

    Pakou, A.; Musumarra, A.; Pierroutsakou, D.; Alamanos, N.; Assimakopoulos, P.A.; Divis, N.; Doukelis, G.; Gillibert, A.; Harissopulos, S.; Kalyva, G.; Kokkoris, M.; Lagoyannis, A.; Mertzimekis, T.J.; Nicolis, N.G.; Papachristodoulou, C.; Perdikakis, G.; Roubos, D.; Rusek, K.; Spyrou, S.; Zarkadas, Ch.

    2007-01-01

    Total reaction cross section measurements for the 6,7 Li + 28 Si systems have been performed at near-barrier energies. The results indicate that, with respect to the potential anomaly at barrier, 6 Li and 7 Li on light targets exhibit similar energy dependence on the imaginary potential. Comparisons are made with 6,7 Li cross sections on light and heavy targets, extracted via previous elastic scattering measurements and also with CDCC calculations. Energy dependent parametrisations are also obtained for total reaction cross sections of 6,7 Li on Si, as well as on any target, at near barrier energies

  10. Preoperative physiotherapy and short-term functional outcomes of primary total knee arthroplasty.

    Science.gov (United States)

    Mat Eil Ismail, Mohd Shukry; Sharifudin, Mohd Ariff; Shokri, Amran Ahmed; Ab Rahman, Shaifuzain

    2016-03-01

    Physiotherapy is an important part of rehabilitation following arthroplasty, but the impact of preoperative physiotherapy on functional outcomes is still being studied. This randomised controlled trial evaluated the effect of preoperative physiotherapy on the short-term functional outcomes of primary total knee arthroplasty (TKA). 50 patients with primary knee osteoarthritis who underwent unilateral primary TKA were randomised into two groups: the physiotherapy group (n = 24), whose patients performed physical exercises for six weeks immediately prior to surgery, and the nonphysiotherapy group (n = 26). All patients went through a similar physiotherapy regime in the postoperative rehabilitation period. Functional outcome assessment using the algofunctional Knee Injury and Osteoarthritis Outcome Score (KOOS) scale and range of motion (ROM) evaluation was performed preoperatively, and postoperatively at six weeks and three months. Both groups showed a significant difference in all algofunctional KOOS subscales (p 0.05). Significant differences were observed in the time-versus-treatment analysis between groups for the symptoms (p = 0.003) and activities of daily living (p = 0.025) subscales. No significant difference in ROM was found when comparing preoperative measurements and those at three months following surgery, as well as in time-versus-treatment analysis (p = 0.928). Six-week preoperative physiotherapy showed no significant impact on short-term functional outcomes (KOOS subscales) and ROM of the knee following primary TKA. Copyright: © Singapore Medical Association.

  11. Primary Total Hip Replacement for a Femoral Neck Fracture in a Below-Knee Amputee

    OpenAIRE

    Masmoudi, Karim; Rbai, H?di; Fradj, Ayman Ben; Sa?dena, Jecem; Boughattas, Anouar

    2016-01-01

    Introduction: Femoral neck fracture on amputated limb is an uncommon lesion and challenging to manage. Case Report: We report a case of a displaced neck fracture of the left femur in a 57-year-old female. She underwent at the age of the three a below-knee amputation of the ipsilateral limb for post traumatic ischemia. The fracture was managed by a total hip arthroplasty (THA), as a primary procedure. In this article we describe our experience of this unusual entity. Conclusion: Total hip arth...

  12. Energy consumption and total factor productivity growth in Iranian agriculture

    Directory of Open Access Journals (Sweden)

    Reza Moghaddasi

    2016-11-01

    Full Text Available In this study we investigated the relation between energy consumption and growth of total factor productivity (TFP of agriculture in Iran from 1974 to 2012 using Solow residual method. The results from estimated aggregate Cobb–Douglas production function showed that one percent change in the value of labor, capital and energy will lead to 4.07, 0.09 and 0.49 percent change in agriculture value added, respectively. Also in a long term, based on the Johansen cointegration test, there is a negative relation between TFP growth and energy consumption in Iranian agriculture which might be due to cheap and inefficient energy use in this sector. Gradual liberalization of energy price and use of so called green box support policies is recommended.

  13. Achievement report for fiscal 1981 on Sunshine Program-entrusted research and development. Research on hydrogen energy total system; 1981 nendo suiso energy total system no kenkyu seika hokokusho

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1982-03-01

    In this research, studies are conducted relative to the time point, form, and magnitude of the introduction of hydrogen into Japan's total energy system. The research aims to construct a hydrogen energy total system consisting of hydrogen energy subsystems to be available in the future and to clearly define the stage at which transfer to the target system will be carried out. In the research for fiscal 1981, studies continue about the feasibility of hydrogen as automobile and aviation fuels and as a material for use in chemical engineering, about conversion into each other of hydrogen and various synthetic fuels and electric power with which hydrogen will have to compete in the domain into which it will be supplied, and about technologies of their utilization for comparison between such energies in the search for their interchangeability. Surveys are conducted on technical data about local energies. The Yakushima island is chosen, for instance, and a conceptual hydrogen energy base is constructed there and the cost for the construction is estimated. At the last part, the feasibility of the introduction of hydrogen into Japan's energy system in the future is discussed for assessment. (NEDO)

  14. Rate and Risk Factors for Periprosthetic Joint Infection Among 36,494 Primary Total Hip Arthroplasties.

    Science.gov (United States)

    Triantafyllopoulos, Georgios K; Soranoglou, Vasileios G; Memtsoudis, Stavros G; Sculco, Thomas P; Poultsides, Lazaros A

    2018-04-01

    As periprosthetic joint infections (PJIs) can have tremendous health and socioeconomic implications, recognizing patients at risk before surgery is of great importance. Therefore, we sought to determine the rate of and risk factors for deep PJI in patients undergoing primary total hip arthroplasty (THA). Clinical characteristics of patients treated with primary THA between January 1999 and December 2013 were retrospectively reviewed. These included patient demographics, comorbidities (including the Charlson/Deyo comorbidity index), length of stay, primary diagnosis, total/allogeneic transfusion rate, and in-hospital complications, which were grouped into local and systemic (minor and major). We determined the overall deep PJI rate, as well as the rates for early-onset (occurring within 2 years after index surgery) and late-onset PJI (occurring more than 2 years after surgery). A Cox proportional hazards regression model was constructed to identify risk factors for developing deep PJI. Significance level was set at 0.05. A deep PJI developed in 154 of 36,494 primary THAs (0.4%) during the study period. Early onset PJI was found in 122 patients (0.3%), whereas late PJI occurred in 32 patients (0.1%). Obesity, coronary artery disease, and pulmonary hypertension were identified as independent risk factors for deep PJI after primary THA. The rate of deep PJIs of the hip is relatively low, with the majority occurring within 2 years after THA. If the optimization of modifiable risk factors before THA can reduce the rate of this complication remains unknown, but should be attempted as part of good practice. Copyright © 2017 Elsevier Inc. All rights reserved.

  15. Rev-Changes in Primary Energy Use and CO2 Emissions—An Impact Assessment for a Building with Focus on the Swedish Proposal for Nearly Zero Energy Buildings

    Directory of Open Access Journals (Sweden)

    Mattias Gustafsson

    2017-07-01

    Full Text Available In the European Union’s Energy Performance of Buildings Directive, the energy efficiency goal for buildings is set in terms of primary energy use. In the proposal from the National Board of Housing, Building, and Planning, for nearly zero energy buildings in Sweden, the use of primary energy is expressed as a primary energy number calculated with given primary energy factors. In this article, a multi-dwelling building is simulated and the difference in the primary energy number is investigated when the building uses heat from district heating systems or from heat pumps, alone or combined with solar thermal or solar photovoltaic systems. It is also investigated how the global CO2 emissions are influenced by the different energy system combinations and with different fuels used. It is concluded that the calculated primary energy number is lower for heat pump systems, but the global CO2 emissions are lowest when district heating uses mostly biofuels and is combined with solar PV systems. The difference is up to 140 tonnes/year. If the aim with the Swedish building code is to decrease the global CO2 emissions then the ratio between the primary energy factors for electricity and heat should be larger than three and considerably higher than today.

  16. Management of Medial Collateral Ligament Injury During Primary Total Knee Arthroplasty: A Systematic Review

    Directory of Open Access Journals (Sweden)

    Paul Della Torre, MD

    2014-07-01

    Full Text Available Medial collateral ligament injury during primary total knee arthroplasty is a recognised complication potentially resulting in valgus instability, suboptimal patient outcomes and a higher rate of revision or reoperation. Options for management include primary repair with or without augmentation, reconstruction or immediate conversion to prosthesis with greater constraint, in conjunction with various postoperative rehabilitation protocols. Inconsistent recommendations throughout the orthopaedic literature have made the approach to managing this complication problematic. The objective of this study was to review the available literature to date comparing intraoperative and postoperative management options for primary total knee arthroplasty complicated by recognised injury to the medial collateral ligament. This systematic literature review was prospectively registered with PROSPERO (#CRD42014008866 and performed in accordance with PRISMA guidelines including a PRISMA flow diagram. Five articles satisfied the inclusion criteria. Each was a retrospective, observational cohort or case series with small numbers reported, inconsistent methodology and incompletely reported outcomes. Four of the five studies managing medial collateral ligament injury during total knee arthroplasty (47/84 patients with direct repair with or without autograft augmentation reported good outcomes with no revision or reoperation required for symptomatic instability over a follow-up period of 16 months to almost 8 years. The fifth study with a follow-up to 10 years and a high rate of conversion to unlinked semi constrained total knee arthroplasty implant (30/37 patients reported a greater incidence of revision due to instability, in patients in whom the medial collateral ligament injury was directly repaired without added constraint. Overall balance of evidence is in favour of satisfactory outcomes without symptomatic instability following direct repair with or without

  17. Relativistic total energy and chemical potential of heavy atoms and positive ions

    International Nuclear Information System (INIS)

    Hill, S.H.; Grout, P.J.; March, N.H.

    1984-01-01

    The relativistic Thomas-Fermi theory, with a finite nucleus, is used to study the variation of the chemical potential μ with atomic number Z and number of electrons N (N <= Z). The difference between the total energy of positive ions and that of the corresponding neutral atom has been obtained. The scaling predictions are confirmed by numerical calculations. The first principles calculation of the relativistic Thomas-Fermi total energy of neutral atoms is also studied. (author)

  18. On the way towards smart energy supply in cities: The impact of interconnecting geographically distributed district heating grids on the energy system

    DEFF Research Database (Denmark)

    Dominkovic, D. F.; Bačeković, I.; Sveinbjörnsson, D.

    2017-01-01

    assessed. Moreover, the impact of industrial waste heat on the DH supply was also assessed. In the reference year (2013) two out of four interconnections proved to be economically viable. The results for the future energy system (2029) showed that interconnecting geographically distributed DH grids reduces...... of the future energy supply system with interconnected DH grids and installed industrial waste heat recuperation results in the lowest primary energy demand, emissions and costs. Finally, the benefits of the interconnected DH grid, in terms of system flexibility, CO2 emissions, total costs and energy efficiency...... primary energy supply by 9.5%, CO2 emissions by 11.1% and total system costs by 6.3%. Inclusion of industrial waste heat in the fully interconnected DH grid reduced primary energy supply for an additional 3%, CO2 emissions for an additional 2.2% and total system costs for an additional 1.3%. The case...

  19. Probability and heritability estimates on primary osteoarthritis of the hip leading to total hip arthroplasty

    DEFF Research Database (Denmark)

    Skousgaard, Søren Glud; Hjelmborg, Jacob; Skytthe, Axel

    2015-01-01

    INTRODUCTION: Primary hip osteoarthritis, radiographic as well as symptomatic, is highly associated with increasing age in both genders. However, little is known about the mechanisms behind this, in particular if this increase is caused by genetic factors. This study examined the risk and heritab......INTRODUCTION: Primary hip osteoarthritis, radiographic as well as symptomatic, is highly associated with increasing age in both genders. However, little is known about the mechanisms behind this, in particular if this increase is caused by genetic factors. This study examined the risk...... and heritability of primary osteoarthritis of the hip leading to a total hip arthroplasty, and if this heritability increased with increasing age. METHODS: In a nationwide population-based follow-up study 118,788 twins from the Danish Twin Register and 90,007 individuals from the Danish Hip Arthroplasty Register...... not have had a total hip arthroplasty at the time of follow-up. RESULTS: There were 94,063 twins eligible for analyses, comprising 835 cases of 36 concordant and 763 discordant twin pairs. The probability increased particularly from 50 years of age. After sex and age adjustment a significant additive...

  20. Energy in Croatia 2011, Annual Energy Report

    International Nuclear Information System (INIS)

    2012-01-01

    With the twentieth edition of the Review Energy in Croatia, Ministry of Economy, Labour and Entrepreneurship continues the practice of informing domestic and foreign public on relations and trends within the Croatian energy sector. This Review gives, in a recognizable and comprehensible way, data and characteristic values relevant to the Croatian energy sector, providing an overview on energy production and consumption at all levels. There is a detailed analysis of the trends present in the energy sector as well as a number of information on capacities, reserves, prices and energy balances for crude oil, all petroleum products, natural gas, electricity, heat energy, coal and renewable energy sources. The Review also brings the main economic and financial indicators, data on air pollutant emissions and main energy efficiancy indicators. It also gives the ODEX energy efficiency index, which is determined according to the methodology used in the European Union. This indicator monitors the energy efficiancy trends over a period of time in the sectors of industry, transport, households and in total consumption. Finally, the Review brings the energy balances of the Republic of Croatia for the years 2010 and 2011, made following the EUROSTAT and IEA methodologies. In 2011 total primary energy supply in Croatia was 6.8 percent lower than the year before. At the same time, gross domestic product slightly decreased by 0.01 percent, which resulted in lowering energy intensity of total energy consumption by a 6.8 percent. When compared to the average energy intensity level in the EU (EU27), the energy intensity in Croatia was only 1.2 percent higher. The primary energy production in 2011 decreased by 18 percent from the previous year. Also, due to unfavorable hydrological situation the hydropower utilization was as much as 46.6 percent lower than in 2010. The energy from renewable sources increased by 13.3 percent and the energy from fuel wood, ondustrial waste wood, energy

  1. Elastic scattering and total cross section at very high energies

    International Nuclear Information System (INIS)

    Castaldi, R.; Sanguinetti, G.

    1985-01-01

    The aim of this review is to summarize the recent progress in the field of elastic scattering and total cross section in this new energy domain. In Section 2 a survey of the experimental situation is outlined. The most significant data are presented, with emphasis on the interpretation, not the specific details or technicalities. This section is therefore intended to give a self-contained look at the field, especially for the nonspecialist. In Section 3, hadron scattering at high energy is described in an impact parameter picture, which provides a model-independent intuitive geometrical representation. The diffractive character of elastic scattering, seen as the shadow of inelastic absorption, is presented as a consequence of unitarity in the s-channel. Spins are neglected throughout this review, inasmuch as the asymptotic behavior in the very high-energy limit is the main concern here. In Section 4 some relevant theorems are recalled on the limiting behavior of hadron-scattering amplitudes at infinite energy. There is also a brief discussion on how asymptotically rising total cross sections imply scaling properties in the elastic differential cross sections. A quick survey of eikonal models is presented and their predictions are compared with ISR and SPS Collider data

  2. Lifetime risk of primary total hip replacement surgery for osteoarthritis from 2003-2013

    DEFF Research Database (Denmark)

    Ackerman, Ilana N; Bohensky, Megan A; de Steiger, Richard

    2017-01-01

    OBJECTIVE: To compare the lifetime risk of total hip replacement surgery (THR) for osteoarthritis (OA) between countries, and over time. METHODS: Data on primary THR procedures performed for OA in 2003 and 2013 were extracted from national arthroplasty registries in Australia, Denmark, Finland, N....... These multi-national risk estimates can inform resource planning for OA service delivery. This article is protected by copyright. All rights reserved....

  3. Managing total corporate electricity/energy market risks

    International Nuclear Information System (INIS)

    Henney, A.; Keers, G.

    1998-01-01

    The banking industry has developed a tool kit of very useful value at risk techniques for hedging risk, but these techniques must be adapted to the special complexities of the electricity market. This paper starts with a short history of the use of value-at-risk (VAR) techniques in banking risk management and then examines the specific and, in many instances, complex risk management challenges faced by electric companies from the behavior of prices in electricity markets and from the character of generation and electric retailing risks. The third section describes the main methods for making VAR calculations along with an analysis of their suitability for analyzing the risks of electricity portfolios and the case for using profit at risk and downside risk as measures of risk. The final section draws the threads together and explains how to look at managing total corporate electricity market risk, which is a big step toward managing total corporate energy market risk

  4. Comparative study of various methods of primary energy estimation in nucleon-nucleon interactions

    International Nuclear Information System (INIS)

    Goyal, D.P.; Yugindro Singh, K.; Singh, S.

    1986-01-01

    The various available methods for the estimation of primary energy in nucleon-nucleon interactions have been examined by using the experimental data on angular distributions of shower particles from p-N interactions at two accelerator energies, 67 and 400 GeV. Three different groups of shower particle multiplicities have been considered for interactions at both energies. It is found that the different methods give quite different estimates of primary energy. Moreover, each method is found to give different values of energy according to the choice of multiplicity groups. It is concluded that the E ch method is relatively the better method among all the methods available, and that within this method, the consideration of the group of small multiplicities gives a much better result. The method also yields plausible estimates of inelasticity in high energy nucleon-nucleon interactions. (orig.)

  5. Measurements of effective total macroscopic cross sections and effective energy of continuum beam

    Energy Technology Data Exchange (ETDEWEB)

    Kobayashi, Hisao [Rikkyo Univ., Yokosuka, Kanagawa (Japan). Inst. for Atomic Energy

    1998-03-01

    Two practically useful quantities are introduced in this study to characterize a continuum neutron beam and to describe transmission phenomena of the beam in field of quantitative neutron radiography: an effective energy instead of a peak energy or a mean energy of the spectrum and an effective total macroscopic (ETM) cross section instead of a total macroscopic (TM) cross section defined at the monochromatic energy. The effective energy was evaluated by means of energy dependence of ETM cross section. To realize the method a beam quality indicator (BQI) has been proposed recently. Several effective energies were measured for non-filtered, filtered neutron beams, and outputs of neutron guide tubes in world by the BQI. A thermal neutron beam and three beams modulated by Pb filters with different thicknesses are studied to measure ETM cross sections for various materials and summarized in a table. Validity of the effective energy determined by the BQI is discussed relating with ETM cross sections of materials. (author)

  6. Composition of cosmic rays in the knee region of the primary energy spectrum

    International Nuclear Information System (INIS)

    Das Gupta, U.

    1989-01-01

    The Soudan Surface-Underground Cosmic Ray Telescope is located at the Soudan iron mine in northern Minnesota. It consists of a coincidence arrangement of two detectors-one installed at the surface of the mine and the other located underground, at a vertical depth of 600 meters. Using such an arrangement, the energy and composition of a primary cosmic ray particle can be determined independently of one another. When a high energy cosmic ray enters the Earth's atmosphere, secondary particles are produced in successive interactions, creating an extensive air shower. Using the surface detector, the number of particles in the shower at the surface of the Earth can be counted and the energy of the primary particle estimated. Of all the particles that are created in a cosmic ray air shower, only the energetic muons are able to penetrate underground. The separations of the muons below ground are measured by the Soudan 1 detector and this serves as an indicator of the type of nucleus that initiated the shower. The Soudan surface-underground detector is sensitive to primary cosmic rays of energies between 10 14 and 10 18 eV. The data from the experiment were compared to the predictions of various cosmic ray composition models, within this energy range. The data supported a composition model that was proton dominated up to the highest energies measured. There was no indication of a shift in the composition towards heavier primaries as would be expected on the basis of some models

  7. Electricity of nuclear origin and primary and end-use energy consumption; Electricite nucleaire et consommation d'energie primaire et finale

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2008-07-01

    In France, the electricity of nuclear origin corresponds to about 40% of the primary energy consumption, while electricity as a whole represents about 23% of the end-use energy. This apparent paradox can be explained by 2 methodological points: 1 - the primary energy consumption, in the case of electricity, includes only the energy of nuclear, hydraulic, wind, photovoltaic and geothermal origin. On the other hand, the end-use energy consumption includes all forms of electricity consumed, i.e. the electricity of both primary and secondary origin. 2 - By international convention, the coefficients used to convert MWth into tpe (ton of petroleum equivalent) can change according to two factors: the power generation source and the type of kWh considered, either produced or consumed. The coexistence of different concepts and definitions is justified by the different usages made with them. Therefore, calculations referring to different definitions or equivalence coefficients are not immediately comparable. (J.S.)

  8. Role of primary sedimentation on plant-wide energy recovery and carbon footprint.

    Science.gov (United States)

    Gori, Riccardo; Giaccherini, Francesca; Jiang, Lu-Man; Sobhani, Reza; Rosso, Diego

    2013-01-01

    The goal of this paper is to show the effect of primary sedimentation on the chemical oxygen demand (COD) and solids fractionation and consequently on the carbonaceous and energy footprints of wastewater treatment processes. Using a simple rational procedure for COD and solids fraction quantification, we quantify the effects of varying fractions on CO2 and CO2-equivalent mass flows, process energy demand and energy recovery. Then we analysed two treatment plants with similar biological nutrient removal processes in two different climatic regions and quantified the net benefit of gravity separation before biological treatment. In the cases analysed, primary settling increases the solid fraction of COD that is processed in anaerobic digestion, with an associated increase in biogas production and energy recovery, and a reduction in overall emissions of CO2 and CO2-equivalent from power importation.

  9. Long-term implications of alternative light-duty vehicle technologies for global greenhouse gas emissions and primary energy demands

    International Nuclear Information System (INIS)

    Kyle, Page; Kim, Son H.

    2011-01-01

    This study assesses global light-duty vehicle (LDV) transport in the upcoming century, and the implications of vehicle technology advancement and fuel-switching on greenhouse gas emissions and primary energy demands. Five different vehicle technology scenarios are analyzed with and without a CO 2 emissions mitigation policy using the GCAM integrated assessment model: a reference internal combustion engine vehicle scenario, an advanced internal combustion engine vehicle scenario, and three alternative fuel vehicle scenarios in which all LDVs are switched to natural gas, electricity, or hydrogen by 2050. The emissions mitigation policy is a global CO 2 emissions price pathway that achieves 450 ppmv CO 2 at the end of the century with reference vehicle technologies. The scenarios demonstrate considerable emissions mitigation potential from LDV technology; with and without emissions pricing, global CO 2 concentrations in 2095 are reduced about 10 ppmv by advanced ICEV technologies and natural gas vehicles, and 25 ppmv by electric or hydrogen vehicles. All technological advances in vehicles are important for reducing the oil demands of LDV transport and their corresponding CO 2 emissions. Among advanced and alternative vehicle technologies, electricity- and hydrogen-powered vehicles are especially valuable for reducing whole-system emissions and total primary energy. - Highlights: → Alternative-fuel LDVs reduce whole-system CO 2 emissions, even without carbon pricing. → Alternative-fuel LDVs enhance the CO 2 mitigation capacity of the transportation sector. → Electric and hydrogen vehicles reduce whole-system primary energy supporting LDV transport.

  10. Nuclear Power and Resource Efficiency—A Proposal for a Revised Primary Energy Factor

    Directory of Open Access Journals (Sweden)

    Ola Eriksson

    2017-06-01

    Full Text Available Measuring resource efficiency can be achieved using different methods, of which primary energy demand is commonly used. The primary energy factor (PEF is a figure describing how much energy from primary resources is being used per unit of energy delivered. The PEF for nuclear power is typically 3, which refers to thermal energy released from fission in relation to electricity generated. Fuel losses are not accounted for. However; nuclear waste represents an energy loss, as current plans for nuclear waste management mostly include final disposal. Based on a literature review and mathematical calculations of the power-to-fuel ratio for nuclear power, PEF values for the open nuclear fuel cycle (NFC option of nuclear power and different power mixes are calculated. These calculations indicate that a more correct PEF for nuclear power would be 60 (range 32–88; for electricity in Sweden (41% nuclear power PEF would change from 1.8 to 25.5, and the average PEF for electricity in the European Union (EU would change from 2.5 to 18. The results illustrate the poor resource efficiency of nuclear power, which paves the way for the fourth generation of nuclear power and illustrates the policy implication of using PEFs which are inconsistent with current waste management plans.

  11. Calculation of total and ionization cross sections for electron scattering by primary benzene compounds

    Science.gov (United States)

    Singh, Suvam; Naghma, Rahla; Kaur, Jaspreet; Antony, Bobby

    2016-07-01

    The total and ionization cross sections for electron scattering by benzene, halobenzenes, toluene, aniline, and phenol are reported over a wide energy domain. The multi-scattering centre spherical complex optical potential method has been employed to find the total elastic and inelastic cross sections. The total ionization cross section is estimated from total inelastic cross section using the complex scattering potential-ionization contribution method. In the present article, the first theoretical calculations for electron impact total and ionization cross section have been performed for most of the targets having numerous practical applications. A reasonable agreement is obtained compared to existing experimental observations for all the targets reported here, especially for the total cross section.

  12. Calculation of total and ionization cross sections for electron scattering by primary benzene compounds

    Energy Technology Data Exchange (ETDEWEB)

    Singh, Suvam; Naghma, Rahla; Kaur, Jaspreet; Antony, Bobby, E-mail: bka.ism@gmail.com [Atomic and Molecular Physics Lab, Department of Applied Physics, Indian School of Mines, Dhanbad (India)

    2016-07-21

    The total and ionization cross sections for electron scattering by benzene, halobenzenes, toluene, aniline, and phenol are reported over a wide energy domain. The multi-scattering centre spherical complex optical potential method has been employed to find the total elastic and inelastic cross sections. The total ionization cross section is estimated from total inelastic cross section using the complex scattering potential-ionization contribution method. In the present article, the first theoretical calculations for electron impact total and ionization cross section have been performed for most of the targets having numerous practical applications. A reasonable agreement is obtained compared to existing experimental observations for all the targets reported here, especially for the total cross section.

  13. Preliminary results of total kinetic energy modelling for neutron-induced fission

    International Nuclear Information System (INIS)

    Visan, I.; Giubega, G.; Tudora, A.

    2015-01-01

    The total kinetic energy as a function of fission fragments mass TKE(A) is an important quantity entering in prompt emission calculations. The experimentally distributions of TKE(A) are referring to a limited number of fission systems and incident energies. In the present paper, a preliminary model for TKE calculation in neutron induced fission system is presented. The range of fission fragments is chosen as in the Point by Point treatment. The model needs as input only mass excesses and deformation parameters taken from available nuclear databases being based on the following approximations: total excitation energy of fully accelerated fission fragments TXE is calculated from energy balance of neutron-induced fission systems as sum of the total excitation energy at scission E*sciss and deformation energy Edef. The deformation energy at scission is given by minimizing the potential energy at the scission configuration. At the scission point, the fission system is described by two spheroidal fragments nearly touching by a pre-scission distance or neck caused by the nuclear forces between fragments. Therefore, the Columbian repulsion depending on neck and, consequently, on the fragments deformation at scission, is essentially in TKE determination. An approximation is made based on the fission modes. For the very symmetric fission, the dominant super long channel is characterized by long distance between fragments leading to low TKE values. Due to magic and double-magic shells closure, the dominant S1 fission mode for pairs with heavy fragment mass AH around 130-134 is characterized by spherical heavy fragment shape and easily deformed light fragment. The nearly spherical shape of the complementary fragments are characterized by minimum distance, and consequently to maximum TKE values. The results obtained for TKE(A) are in good agreement with existing experimental data for many neutron induced fission systems, e.g. ''2''3''3&apos

  14. The Use of Energy in Malaysia: Tracing Energy Flows from Primary Source to End Use

    Directory of Open Access Journals (Sweden)

    Chinhao Chong

    2015-04-01

    Full Text Available Malaysia is a rapidly developing country in Southeast Asia that aims to achieve high-income country status by 2020; its economic growth is highly dependent on its abundant energy resources, especially natural gas and crude oil. In this paper, a complete picture of Malaysia’s energy use from primary source to end use is presented by mapping a Sankey diagram of Malaysia’s energy flows, together with ongoing trends analysis of the main factors influencing the energy flows. The results indicate that Malaysia’s energy use depends heavily on fossil fuels, including oil, gas and coal. In the past 30 years, Malaysia has successfully diversified its energy structure by introducing more natural gas and coal into its power generation. To sustainably feed the rapidly growing energy demand in end-use sectors with the challenge of global climate change, Malaysia must pay more attention to the development of renewable energy, green technology and energy conservation in the future.

  15. Energy in Croatia 2005, Annual Energy Report

    International Nuclear Information System (INIS)

    2006-12-01

    Report presents the latest information on relations and trends in the Croatian energy sector. The reports gives a familiar overview of comprehensive data about and representative features of the Croatian energy sector, related to the supply and demand of energy at all levels. It produces a detailed analysis of energy trends and provides extensive data on capacity, reserves and prices as well as balances of individual energy sources - crude oil, petroleum products, natural gas, electricity, heat, coal and renewable source of energy. Basic economic and financial indicators, emissions of air pollutants and basic energy efficiency indicators for Croatia are also presented. In 2005, total primary energy supply in Croatia decreased slightly by 0.1 per cent with respect to the previous year. At the same time, GDP rose by 4.3 per cent, resulting in a drop in energy intensity of the total primary energy supply of 4.2 per cent. The energy intensity in Croatia was 20.1 per cent higher than the average energy intensity in the European Union, but a positive decreasing trend was noted during the past period. In 2005 the total primary energy production in Croatia fell by 3.5 per cent with respect to the previous year. The highest decrease was recorded in harnessing hydro power, and the production of crude oil and fuel wood also declined. Only the production of natural gas showed a growth of 3.5 per cent. Due to the decrease in the primary energy production, energy self-supply was also reduced to 47.9 per cent. A less value was achieved only in the year 2003. A continuing trend towards a gradual decline in energy self-supply was present throughout the past several years. Final energy demand increased by 3 per cent while demands in other sectors decreased. Energy transformation losses were reduced by 7 per cent, non-energy use declined by 5.6 per cent and energy transmission and distribution losses by 5.5 per cent, and there was a slight drop of 0.2 per cent in demand in energy

  16. Life cycle primary energy use and carbon emission of an eight-storey wood-framed apartment building

    Energy Technology Data Exchange (ETDEWEB)

    Gustavsson, Leif; Joelsson, Anna; Sathre, Roger [Ecotechnology, Department of Engineering and Sustainable Development, Mid Sweden University, 83125 Oestersund (Sweden)

    2010-02-15

    In this study the life cycle primary energy use and carbon dioxide (CO{sub 2}) emission of an eight-storey wood-framed apartment building are analyzed. All life cycle phases are included, including acquisition and processing of materials, on-site construction, building operation, demolition and materials disposal. The calculated primary energy use includes the entire energy system chains, and carbon flows are tracked including fossil fuel emissions, process emissions, carbon stocks in building materials, and avoided fossil emissions due to biofuel substitution. The results show that building operation uses the largest share of life cycle energy use, becoming increasingly dominant as the life span of the building increases. The type of heating system strongly influences the primary energy use and CO{sub 2} emission; a biomass-based system with cogeneration of district heat and electricity achieves low primary energy use and very low CO{sub 2} emissions. Using biomass residues from the wood products chain to substitute for fossil fuels significantly reduces net CO{sub 2} emission. Excluding household tap water and electricity, a negative life cycle net CO{sub 2} emission can be achieved due to the wood-based construction materials and biomass-based energy supply system. This study shows the importance of using a life cycle perspective when evaluating primary energy and climatic impacts of buildings. (author)

  17. A Different View of Solar Spectral Irradiance Variations: Modeling Total Energy over Six-Month Intervals.

    Science.gov (United States)

    Woods, Thomas N; Snow, Martin; Harder, Jerald; Chapman, Gary; Cookson, Angela

    A different approach to studying solar spectral irradiance (SSI) variations, without the need for long-term (multi-year) instrument degradation corrections, is examining the total energy of the irradiance variation during 6-month periods. This duration is selected because a solar active region typically appears suddenly and then takes 5 to 7 months to decay and disperse back into the quiet-Sun network. The solar outburst energy, which is defined as the irradiance integrated over the 6-month period and thus includes the energy from all phases of active region evolution, could be considered the primary cause for the irradiance variations. Because solar cycle variation is the consequence of multiple active region outbursts, understanding the energy spectral variation may provide a reasonable estimate of the variations for the 11-year solar activity cycle. The moderate-term (6-month) variations from the Solar Radiation and Climate Experiment (SORCE) instruments can be decomposed into positive (in-phase with solar cycle) and negative (out-of-phase) contributions by modeling the variations using the San Fernando Observatory (SFO) facular excess and sunspot deficit proxies, respectively. These excess and deficit variations are fit over 6-month intervals every 2 months over the mission, and these fitted variations are then integrated over time for the 6-month energy. The dominant component indicates which wavelengths are in-phase and which are out-of-phase with solar activity. The results from this study indicate out-of-phase variations for the 1400 - 1600 nm range, with all other wavelengths having in-phase variations.

  18. Assessment and Decomposition of Total Factor Energy Efficiency: An Evidence Based on Energy Shadow Price in China

    Directory of Open Access Journals (Sweden)

    Peihao Lai

    2016-04-01

    Full Text Available By adopting an energy-input based directional distance function, we calculated the shadow price of four types of energy (i.e., coal, oil, gas and electricity among 30 areas in China from 1998 to 2012. Moreover, a macro-energy efficiency index in China was estimated and divided into intra-provincial technical efficiency, allocation efficiency of energy input structure and inter-provincial energy allocation efficiency. It shows that total energy efficiency has decreased in recent years, where intra-provincial energy technical efficiency drops markedly and extensive mode of energy consumption rises. However, energy structure and allocation improves slowly. Meanwhile, lacking an integrated energy market leads to the loss of energy efficiency. Further improvement of market allocation and structure adjustment play a pivotal role in the increase of energy efficiency.

  19. The International Energy Agency's world energy outlook

    International Nuclear Information System (INIS)

    O'Dell, S.

    1996-01-01

    The 1996 edition of the World Energy Outlook to 2010 was reviewed. An overview of the energy projections was provided based on assumptions about economic growth and energy prices, geological potential, technological developments, the availability of traditional fuels outside the OECD and the future preferences of energy users. Demand vs. price movements were modelled, based on 'capacity constraints' and 'energy saving ' scenarios. Three major conclusions derived from the projections were: (1) world primary energy demand will grow steadily as it has over the past two decades, (2) fossil fuels will account for 90 per cent of total primary energy demand in 2010, and (3) a structural shift in the shares of different regions in world energy demand is likely to occur, i.e., the OECD share will fall in favor of the share of the ROW (rest of the world). 4 tabs., 9 figs

  20. Small phytoplankton contribution to the standing stocks and the total primary production in the Amundsen Sea

    Directory of Open Access Journals (Sweden)

    S. H. Lee

    2017-08-01

    Full Text Available Small phytoplankton are anticipated to be more important in a recently warming and freshening ocean condition. However, little information on the contribution of small phytoplankton to overall phytoplankton production is currently available in the Amundsen Sea. To determine the contributions of small phytoplankton to total biomass and primary production, carbon and nitrogen uptake rates of total and small phytoplankton were obtained from 12 productivity stations in the Amundsen Sea. The daily carbon uptake rates of total phytoplankton averaged in this study were 0.42 g C m−2 d−1 (SD  =  ± 0.30 g C m−2 d−1 and 0.84 g C m−2 d−1 (SD  =  ± 0.18 g C m−2 d−1 for non-polynya and polynya regions, respectively, whereas the daily total nitrogen (nitrate and ammonium uptake rates were 0.12 g N m−2 d−1 (SD  =  ± 0.09 g N m−2 d−1 and 0.21 g N m−2 d−1 (SD  =  ± 0.11 g N m−2 d−1, respectively, for non-polynya and polynya regions, all of which were within the ranges reported previously. Small phytoplankton contributed 26.9 and 27.7 % to the total carbon and nitrogen uptake rates of phytoplankton in this study, respectively, which were relatively higher than the chlorophyll a contribution (19.4 % of small phytoplankton. For a comparison of different regions, the contributions for chlorophyll a concentration and primary production of small phytoplankton averaged from all the non-polynya stations were 42.4 and 50.8 %, which were significantly higher than those (7.9 and 14.9 %, respectively in the polynya region. A strong negative correlation (r2 = 0. 790, p<0. 05 was found between the contributions of small phytoplankton and the total daily primary production of phytoplankton in this study. This finding implies that daily primary production decreases as small phytoplankton contribution increases, which is

  1. 18 CFR 2.400 - Statement of interpretation of waste concerning natural gas as the primary energy source for...

    Science.gov (United States)

    2010-04-01

    ... interpretation of waste concerning natural gas as the primary energy source for qualifying small power production... concerning natural gas as the primary energy source for qualifying small power production facilities. For purposes of deciding whether natural gas may be considered as waste as the primary energy source pursuant...

  2. Optimal Offering Strategies for Wind Power in Energy and Primary Reserve Markets

    DEFF Research Database (Denmark)

    Soares, Tiago; Pinson, Pierre; Jensen, Tue Vissing

    2016-01-01

    generation from the turbines. These offering strategies aim at maximizing expected revenues from both market floors using probabilistic forecasts for wind power generation, complemented with estimated regulation costs and penalties for failing to provide primary reserve. A set of numerical examples, as well......Wind power generation is to play an important role in supplying electric power demand, and will certainly impact the design of future energy and reserve markets. Operators of wind power plants will consequently develop adequate offering strategies, accounting for the market rules...... and the operational capabilities of the turbines, e.g., to participate in primary reserve markets. We consider two different offering strategies for joint participation of wind power in energy and primary reserve markets, based on the idea of proportional and constant splitting of potentially available power...

  3. Annual Energy Review, 2008

    Energy Technology Data Exchange (ETDEWEB)

    None

    2009-06-01

    The Annual Energy Review (AER) is the Energy Information Administration's (EIA) primary report of annual historical energy statistics. For many series, data begin with the year 1949. Included are statistics on total energy production, consumption, trade, and energy prices; overviews of petroleum, natural gas, coal, electricity, nuclear energy, renewable energy, and international energy; financial and environment indicators; and data unit conversions.

  4. DWBA differential and total pair production cross sections for intermediate energy photons

    International Nuclear Information System (INIS)

    Selvaraju, C.; Bhullar, A.S.; Sud, K.K.

    2001-01-01

    We present in this communication the theoretical differential and total cross section for electron-positron pair creation by intermediate energy photons (5.0-10.0 MeV) on different targets (Z=1, 30, 50, 68, 82 and 92). The computed cross sections are in distorted wave Born approximation (DWBA) in point Coulomb potential. The database of the differential and total pair production cross sections is presented in tabulated as well as in graphical form and the interpolation of differential cross sections for different atomic numbers, positron and photon energies is discussed

  5. Energy in Croatia 2007, Annual Energy Report

    International Nuclear Information System (INIS)

    2008-01-01

    With a great deal of pleasure we present the sixteenth edition of the review Energy in Croatia. With this Review the Ministry of Economy, Labor and Entrepreneurship continues the practice of informing domestic and foreign public on relations and trends within the Croatian energy sector. This Review gives data and characteristic values relevant to the Croatian energy sector, providing an overview on energy production and consumption at all levels. There is a detailed analysis of the trends present in the energy sector as well as a number of information on capacities, reserves, prices and energy balances for crude oil, all petroleum products, natural gas, electricity, heat energy, coal and renewable energy sources. The Review also brings the main economic and financial indicators, data on air pollutant emissions and main energy efficiency indicators. It also gives the ODEX energy efficiency index, which is determined according to the methodology used in the European Union. This indicator monitors the energy efficiency trends over a period of time in the sectors of industry, transport, households and in total consumption. Finally, the Review brings the energy balances of the Republic of Croatia for the years 2006 and 2007, made following the EUROSTAT and IEA methodologies. Total annual energy consumption in Croatia in 2007 increased by 1.5 percent from the previous year. At the same time gross domestic product increased by 5.6 percent, which resulted in a continuing energy intensity reduction, by 3.8 percent. In relation the European Union (EU 27), energy intensity in Croatia was 16.5 percent above the European average. In 2007 the Croatian production of primary energy decreased by 6.4 percent. The production decrease was recorded in most of primary energy forms. The only energy forms with growing production in 2007 were natural gas production and energy from renewable sources. Due to unfavorable hydrology in 2007, hydro power utilization decreased by 27.4 percent

  6. Effect of thermal mass on life cycle primary energy balances of a concrete- and a wood-frame building

    International Nuclear Information System (INIS)

    Dodoo, Ambrose; Gustavsson, Leif; Sathre, Roger

    2012-01-01

    Highlights: ► The effect of thermal mass on life cycle primary energy balance of concrete and wood building is analyzed. ► A concrete building has slightly lower space heating demand than a wood alternative. ► Still, a wood building has a lower life cycle primary energy use than a concrete alternative. ► The influence of thermal mass on space heating energy use for buildings in Nordic climate is small. -- Abstract: In this study we analyze the effect of thermal mass on space heating energy use and life cycle primary energy balances of a concrete- and a wood-frame building. The analysis includes primary energy use during the production, operation, and end-of-life phases. Based on hour-by-hour dynamic modeling of heat flows in building mass configurations we calculate the energy saving benefits of thermal mass during the operation phase of the buildings. Our results indicate that the energy savings due to thermal mass is small and varies with the climatic location and energy efficiency levels of the buildings. A concrete-frame building has slightly lower space heating demand than a wood-frame alternative, due to the higher thermal mass of concrete-based materials. Still, a wood-frame building has a lower life cycle primary energy balance than a concrete-frame alternative. This is due primarily to the lower production primary energy use and greater bioenergy recovery benefits of the wood-frame buildings. These advantages outweigh the energy saving benefits of thermal mass. We conclude that the influence of thermal mass on space heating energy use for buildings located in Nordic climate is small and that wood-frame buildings with cogeneration based district heating would be an effective means of reducing primary energy use in the built environment.

  7. Energy outlook for the APEC region

    International Nuclear Information System (INIS)

    Priddle, R.

    1996-01-01

    The outlook for energy demand in the Asia-Pacific Economic Cooperation (APEC) region to 2010 is summarized under two scenarios: capacity constraints, in which energy price increases dampen demand, and energy savings, in which energy demand growth is dampened by improvements to the underlying energy intensity trends. In the capacity constraints case, total APEC primary energy demand is projected to increase by more than 50 percent, at an average annual rate of 2.3 percent. Natural gas and solids (mostly coal) are expected to be the fastest growing fossil fuels. In the energy savings case, total primary energy demand could increase by 42 percent, an annual average rate of 2 percent. Projected demands for energy are presented, categorized by fuel: oil demand/supply, natural gas, coal and other solid fuel, electricity and heat, hydroelectric power, and nuclear power. (author). 4 tabs., 3 figs

  8. Energy in France. Reference data

    International Nuclear Information System (INIS)

    2001-01-01

    This small guidebook summarizes the main statistical data on energy for France. Data are presented in tables and graphs for the last decades up to the year 2000: energy in economy (contribution of energy industries to the national gross product, employment and investments in the energy sector), overall energies (average monthly price of crude oil, public opinion about nuclear energy, supplies and consumptions, primary energy production, consumption per energy and per sector, energy bill, import crude oil prices), petroleum (primary production, sectoral end-consumption of refined petroleum products, consumption per type of product, automotive fuels demand, imports and exports of petroleum products, petroleum bill), natural gas (total production, sectoral consumption, imports per country of production, imports bill), coal (production, sectoral consumption, imports per country of production), electricity (gross production, classical thermal production per type of fuel, simplified status, sectoral final consumption, nuclear sites, electricity trades with foreign countries), renewable energies (total production, district heating networks, wood consumption, installed wind power, solar thermal and photovoltaic production), rational use of energy (primary energy intensity, compared evolutions of the national gross product with the energy consumption, cumulated energy savings), prices (energies in the industry and in the domestic sectors, automotive fuels, energy consumptions in households), environment (sectoral and net CO 2 emissions). An energy units conversion table is added at the end of the booklet. (J.S.)

  9. Danish survey of acetabular component positioning practice during primary total hip arthroplasty

    DEFF Research Database (Denmark)

    Cotong, Dana; Troelsen, Anders; Husted, Henrik

    2017-01-01

    questions on optimal component positioning, surgical practice patterns in primary THA, indications and surgical techniques used in revision THA. RESULTS: A total of 42 questionnaires were collected, two were excluded, leaving 40 for analyses. 97% of the surgeons reported an optimum cup anteversion within...... the Lewinnek and Callanan "safe zones", whereas 97% and 83% reported optimum cup inclination within the Lewinnek and Callanan "safe zones", respectively. The reported range for optimal cup positioning varied from 30-55 degrees of inclination and 15-30 degrees of anteversion. The minimum and max-imum accepted...

  10. 2003 energy situation of France

    International Nuclear Information System (INIS)

    2004-04-01

    This short document summarizes the key data of the 2003 energy status of France: real and climate-corrected total primary energy consumption, end-use energy consumption (demand per energy source and per sector of use), power supply and demand, and CO 2 emissions. (J.S.)

  11. HYBRID LAYER THICKNESS IN PRIMARY AND PERMANENT TEETH – A COMPARISON BETWEEN TOTAL ETCH ADHESIVES

    Directory of Open Access Journals (Sweden)

    Natalia Gateva

    2012-05-01

    Full Text Available Purpose: The aim this study is to compare the hybrid layer thickness and its micromorphological characteristics in samples from primary and permanent teeth following application of total etch adhesives.Materials and methods: On intact specimens of 20 primary and 10 permanent teeth was created flat dentin surfaces. The patterns were divided in 6 groups. Two different total etch adhesive systems were used – one tree steps (OptiBond, Kerr and one two steps (Exite, VivaDent. In groups 3, 4, 5 and 6 recommended etching time was used - 15 s, in groups 1 and 2 the etching time was reduced to 7 s. After applying the adhesive, resin composite build-ups were constructed. Thus restored samples are stored in saline solution for 24 hours at temperature 37 C. Then they are subjected to thermal stress in temperature between 5 C to 55 C for 1,500 cycles and to masticatory stress – 150,000 cycles with force 100 N in intervals of 0.4 s. After that the teeth are cut through the middle in medio-distal direction with a diamond disc. SEM observation was done to investigate the thickness of the hybrid layer and the presence of microgaps. Statistical analysis was performed with ANOVA and Tukey׳s tests.Results: SEM observation showed significant differences of the hybrid layer thickness between primary and permanent teeth under equal conditions and after different etching time. Group 6 presented the highest average thickness 8.85 μ and group 1 the lowest average in hybrid layer 3.74 μ.Conclusion: In primary teeth the hybrid layer thickness increases with the increased etching time. The hybrid layer thickness in primary teeth is greater than that of the hybrid layer in permanent teeth under equal conditions. For primary teeth it is more appropriate to reduce the etching time to 7s to obtain a hybrid layer with better quality

  12. Total-factor energy efficiency of regions in Japan

    Energy Technology Data Exchange (ETDEWEB)

    Honma, Satoshi [Faculty of Economics, Kyushu Sangyo University, 2-3-1 Matsukadai, Higashi-ku, Fukuoka 813-8503 (Japan); Hu, Jin-Li [Institute of Business and Management, National Chiao Tung University (China)

    2008-02-15

    This study computes the regional total-factor energy efficiency (TFEE) in Japan by employing the data envelopment analysis (DEA). A dataset of 47 prefectures in Japan for the period 1993-2003 is constructed. There are 14 inputs, including three production factors (labor employment, private, and public capital stocks) and 11 energy sources (electric power for commercial and industrial use, electric power for residential use, gasoline, kerosene, heavy oil, light oil, city gas, butane gas, propane gas, coal, and coke). GDP is the sole output. Following Fukao and Yue [2000. Regional factor inputs and convergence in Japan - how much can we apply closed economy neoclassical growth models? Economic Review 51, 136-151 (in Japanese)], data on private and public capital stocks are extended. All the nominal variables are transformed into real variables, taking into consideration the 1995 price level. For kerosene, gas oil, heavy oil, butane gas, coal, and coke, there are a few prefectures with TFEEs less than 0.7. The five most inefficient prefectures are Niigata, Wakayama, Hyogo, Chiba, and Yamaguchi. Inland regions and most regions along the Sea of Japan are efficient in energy use. Most of the inefficient prefectures that are developing mainly upon energy-intensive industries are located along the Pacific Belt Zone. A U-shaped relation similar to the environmental Kuznets curve (EKC) is discovered between energy efficiency and per capita income for the regions in Japan. (author)

  13. Total-factor energy efficiency of regions in Japan

    International Nuclear Information System (INIS)

    Honma, Satoshi; Hu, Jin-Li

    2008-01-01

    This study computes the regional total-factor energy efficiency (TFEE) in Japan by employing the data envelopment analysis (DEA). A dataset of 47 prefectures in Japan for the period 1993-2003 is constructed. There are 14 inputs, including three production factors (labor employment, private, and public capital stocks) and 11 energy sources (electric power for commercial and industrial use, electric power for residential use, gasoline, kerosene, heavy oil, light oil, city gas, butane gas, propane gas, coal, and coke). GDP is the sole output. Following Fukao and Yue [2000. Regional factor inputs and convergence in Japan-how much can we apply closed economy neoclassical growth models? Economic Review 51, 136-151 (in Japanese)], data on private and public capital stocks are extended. All the nominal variables are transformed into real variables, taking into consideration the 1995 price level. For kerosene, gas oil, heavy oil, butane gas, coal, and coke, there are a few prefectures with TFEEs less than 0.7. The five most inefficient prefectures are Niigata, Wakayama, Hyogo, Chiba, and Yamaguchi. Inland regions and most regions along the Sea of Japan are efficient in energy use. Most of the inefficient prefectures that are developing mainly upon energy-intensive industries are located along the Pacific Belt Zone. A U-shaped relation similar to the environmental Kuznets curve (EKC) is discovered between energy efficiency and per capita income for the regions in Japan

  14. The total energy-momentum tensor for electromagnetic fields in a dielectric

    Science.gov (United States)

    Crenshaw, Michael E.

    2017-08-01

    mv. Newtonian fluids can behave very much like dust with the same energy-momentum tensor. The energy and momentum conservation properties of light propagating in the vacuum were long-ago cast in the energy-momentum tensor formalism in terms of the electromagnetic energy density and electromagnetic momentum density. However, extrapolating the tensor theory of energy-momentum conservation for propagation of light in the vacuum to propagation of light in a simple linear dielectric medium has proven to be problematic and controversial. A dielectric medium is not "otherwise empty" and it is typically assumed that optically induced forces accelerate and decelerate nanoscopic material constituents of the dielectric. The corresponding material energy-momentum tensor is added to the electromagnetic energy-momentum tensor to form the total energy-momentum tensor, thereby ensuring that the total energy and the total momentum of the thermodynamically closed system remain constant in time.

  15. Annual Energy Review, 1995

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-07-01

    This document presents statistics on energy useage for 1995. A reviving domestic economy, generally low energy prices, a heat wave in July and August, and unusually cold weather in November and December all contributed to the fourth consecutive year of growth in U.S. total energy consumption, which rose to an all-time high of almost 91 quadrillion Btu in 1995 (1.3). The increase came as a result of increases in the consumption of natural gas, coal, nuclear electric power, and renewable energy. Petroleum was the primary exception, and its use declined by only 0.3 percent. (Integrating the amount of renewable energy consumed outside the electric utility sector into U.S. total energy consumption boosted the total by about 3.4 quadrillion Btu, but even without that integration, U.S. total energy consumption would have reached a record level in 1995.)

  16. Total, accessible and reserve wind energy resources in Bulgaria

    International Nuclear Information System (INIS)

    Ivanov, P.; Trifonova, L.

    1996-01-01

    The article is a part of the international project 'Bulgaria Country Study to Address Climate Change Inventory of the Greenhouse Gases Emission and Sinks Alternative Energy Balance and Technology Programs' sponsored by the Department of Energy, US. The 'total' average annual wind resources in Bulgaria determined on the basis wind velocity density for more than 100 meteorological stations are estimated on 125 000 TWh. For the whole territory the theoretical wind power potential is about 14200 GW. The 'accessible' wind resources are estimated on about 62000 TWh. The 'reserve' (or usable) wind resources are determined using 8 velocity intervals for WECS (Wind Energy Conversion Systems) operation, number and disposition of turbines, and the usable (3%) part of the territory. The annual reserve resources are estimated at about 21 - 33 TWh. The 'economically beneficial' wind resources (EBWR) are those part of the reserve resources which could be included in the country energy balance using specific technologies in specific time period. It is foreseen that at year 2010 the EBWR could reach 0.028 TWh. 7 refs., 2 tabs., 1 fig

  17. Going nuclear. Some implications of the introduction of nuclear energy as the basic primary energy supply of a developped society

    International Nuclear Information System (INIS)

    Haefele, W.; Sassin, W.

    1975-01-01

    On the basis of nuclear energy as primary energy source, the future development potentialities of secondary energies are considered; these energy forms are coal gaseification, process heat for industrial uses and district heating, and mainly hydrogen production which represents 60% of the future secondary energy demands. By using decision tree method, the eventuality of using nuclear energy as unique energy source is examined, and the successive options implied in this approach are analyzed [fr

  18. Postoperative Pain Management After Primary Total Knee Arthroplasty: The Value of Liposomal Bupivacaine.

    Science.gov (United States)

    Sporer, Scott M; Rogers, Thea

    2016-11-01

    Multimodal pain protocols have been proposed to achieve improved long-acting postoperative analgesia. Controlling postoperative pain after joint arthroplasty is especially important as it relates to patient satisfaction and outcomes. The purpose of this study was to compare the postoperative pain, time to ambulation, and overall narcotic usage between patients who received either a femoral nerve block with a periarticular bupivacaine injection or a periarticular bupivacaine and extended-release liposomal bupivacaine injection after primary total knee arthroplasty. A total of 597 consecutive primary total knee arthroplasties performed between September 1, 2012 and August 31, 2014 received preoperative celecoxib, oxycodone, and transdermal scopolamine. Intraoperatively, patients either received a single-dose bupivacaine femoral nerve block along with 30-mL 0.25% bupivacaine periarticular injection (group A) or a 60-mL periarticular injection alone (20-mL liposomal bupivacaine, 30-mL 0.25% bupivacaine, and 10-mL saline; group B). The postoperative pain scores, narcotic usage, and time to ambulation were retrospectively collected from the electronic medical record. These outcomes were compared between treatment groups. There were 325 patients in group A compared with 272 in group B during the time frame. There was no difference among age, gender, race, and body mass index between the groups. Group B demonstrated a decreased need for breakthrough pain medication (16.9% vs 36.3% P bupivacaine resulted in a decrease need for breakthrough pain medication, improved pain scores at 12 hours, and an earlier time to ambulation compared to a combined femoral nerve block and periarticular bupivacaine injection. Copyright © 2016 Elsevier Inc. All rights reserved.

  19. Clinical outcome after treatment of infected primary total knee arthroplasty

    DEFF Research Database (Denmark)

    Husted, Henrik; Jensen, Tim Toftgaard

    2002-01-01

    Twenty-six consecutive cases of infected primary total knee arthroplasties were treated at our institution from 1989 through 2000. Eleven patients had debridement and irrigation performed within 2 months of index arthroplasty or hematogenous spread; only one infection was eradicated. Twenty......-five patients had their prostheses removed; 17 had two-stage revision arthroplasty, following which infection was eradicated in 15; one had a permanent spacer, 7 had arthrodesis (following failed revision arthroplasty in one) and 2 had a femur amputation (following failed revision arthroplasty in one) at follow......-up of mean 24 months. Infections were cured equally well with revision arthroplasty and arthrodesis. Among the 15 patients who ended up with revision arthroplasty, 11 had a better range of motion compared to the index arthroplasty, but 8 had daily pain. We present our treatment protocol, which eradicated 15...

  20. Patient dissatisfaction with rehabilitation following primary total knee arthroplasty.

    Science.gov (United States)

    Johnson, Aaron J; Issa, Kimona; Naziri, Qais; Harwin, Steven F; Bonutti, Petter M; Mont, Michael A

    2013-12-01

    Most patients who receive a total knee arthroplasty (TKA) undergo rehabilitation in the postoperative period. However, these therapies are often not under the direct supervision of the treating physicians, have variable protocols, and have unclear long-term efficacies. The purposes of this study were to assess patient satisfaction with their rehabilitation following TKA and to evaluate whether various factors were different between satisfied and unsatisfied patients. A total of 100 consecutive patients who underwent 107 primary TKA were prospectively surveyed to evaluate their rehabilitation experiences. There were 28 men and 72 women who had a mean age of 61 years (range, 37 to 91 years) at the time of surgery. Patients answered questions regarding the number and duration of therapies, amount of hands-on time with the therapists, number of different therapists, amount of co-pay, and their overall level of satisfaction with their rehabilitation experience. Over one-third of the patients reported not being satisfied with their rehabilitation experiences. The patients who were dissatisfied reported a shorter mean duration of each therapy session spent directly with the therapist, a higher mean number of therapists seen over the duration of their treatment, and an increased number of co-participants during their therapy sessions. The authors believe that to minimize patient dissatisfaction with rehabilitation, surgeons should refer patients to therapists who are willing to spend adequate hands-on time during one-on-one or smaller group therapy sessions with their patients. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  1. Achievement report on research and development in the Sunshine Project in fiscal 1978. Studies on a hydrogen energy total system; 1978 nendo suiso energy total system no kenkyu seika hokokusho

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1979-03-01

    Analysis was made on timing, patterns and scales of introducing hydrogen energy into the Japan's total energy system, and case studies were made on transfer of the comprehensive systems that can be realized in the years of 1985, 2000 and 2025. The basic conception for the analytic method employed a method to analyze and present theoretically the conditions in which prerequisites or results of the estimation can be established, rather than intending elucidation of the estimation itself. An energy model was used for the theoretical means thereof. The objective function to be optimized was assumed to maximize (estimate over the planned period of time) the total effectiveness of the hydrogen energy system converted into the present value being given appropriate discount. The economic performance measures for different secondary energies working as the comparison measures are the limiting production cost of each energy. A consideration was given to the point that the electrolytic hydrogen cannot compete with that made by using the thermo-chemical method (if developed successfully) using heat from high-temperature gas reactor if the fossil fuel price rises sharply. Considerations are also required in replaceability of hydrogen energy with other energies, and hydrogen utilization in petroleum refining. (NEDO)

  2. Total Energy of Charged Black Holes in Einstein-Maxwell-Dilaton-Axion Theory

    Directory of Open Access Journals (Sweden)

    Murat Korunur

    2012-01-01

    Full Text Available We focus on the energy content (including matter and fields of the Møller energy-momentum complex in the framework of Einstein-Maxwell-Dilaton-Axion (EMDA theory using teleparallel gravity. We perform the required calculations for some specific charged black hole models, and we find that total energy distributions associated with asymptotically flat black holes are proportional to the gravitational mass. On the other hand, we see that the energy of the asymptotically nonflat black holes diverge in a limiting case.

  3. Comparison of biomolecule desorption yields for low and high energy primary ions

    International Nuclear Information System (INIS)

    Kamensky, I.; Hakansson, P.; Sundqvist, B.; McNeal, C.J.; MacFarlane, R.

    1982-01-01

    Ion induced desorption yields of molecular ions from samples of cesium iodide, glycylglycine, ergosterol, bleomycin and a trinucleoside diphosphate have been studied using primary beams of 54 MeV 63 Cu 9+ and 3 keV 133 Cs + . Mass analysis was performed with a time-of-flight technique. Each sample was studied with the same spectrometer for both low and high energy primary ions and without opening of the vacuum chamber in between the measurements. The results show that fast heavy ions give larger yields for all samples studied and that the yield ratios for high to low energy desorption increase with the mass of the sample molecule. (orig.)

  4. Relation between total shock energy and mortality in patients with implantable cardioverter-defibrillator.

    Science.gov (United States)

    Tenma, Taro; Yokoshiki, Hisashi; Mitsuyama, Hirofumi; Watanabe, Masaya; Mizukami, Kazuya; Kamada, Rui; Takahashi, Masayuki; Sasaki, Ryo; Maeno, Motoki; Okamoto, Kaori; Chiba, Yuki; Anzai, Toshihisa

    2018-05-15

    Implantable Cardioverter-Defibrillator (ICD) shocks have been associated with mortality. However, no study has examined the relation between total shock energy and mortality. The aim of this study is to assess the association of total shock energy with mortality, and to determine the patients who are at risk of this association. Data from 316 consecutive patients who underwent initial ICD implantation in our hospital between 2000 and 2011 were retrospectively studied. We collected shock energy for 3 years from the ICD implantation, and determined the relation of shock energy on mortality after adjusting confounding factors. Eighty-seven ICD recipients experienced shock(s) within 3 years from ICD implantation and 43 patients had died during the follow-up. The amount of shock energy was significantly associated with all-cause death [adjusted hazard ratio (HR) 1.26 (per 100 joule increase), p energy accumulation (≥182 joule) was lower (p energy accumulation (energy accumulation and all-cause death was remarkable in the patients with low left ventricular ejection fraction (LVEF ≤40%) or atrial fibrillation (AF). Increase of shock energy was related to mortality in ICD recipients. This relation was evident in patients with low LVEF or AF. Copyright © 2018 Elsevier B.V. All rights reserved.

  5. A multisite interaction expansion of the total energy in metals

    International Nuclear Information System (INIS)

    Sowa, E.C.; Gonis, A.

    1994-01-01

    The local-density approximation provides a proper setting for the decomposition of total energy into many-body (many-atom) contributions. Multiple scattering theory in turn provides a convenient framework for carrying out this process. We illustrate this concept with calculations on a linear chain of atoms in bulk copper

  6. The total flow concept for geothermal energy conversion

    Science.gov (United States)

    Austin, A. L.

    1974-01-01

    A geothermal development project has been initiated at the Lawrence Livermore Laboratory (LLL) to emphasize development of methods for recovery and conversion of the energy in geothermal deposits of hot brines. Temperatures of these waters vary from 150 C to more than 300 C with dissolved solids content ranging from less than 0.1% to over 25% by weight. Of particular interest are the deposits of high-temperature/high-salinity brines, as well as less saline brines, known to occur in the Salton Trough of California. Development of this resource will depend on resolution of the technical problems of brine handling, scale and precipitation control, and corrosion/erosion resistant systems for efficient conversion of thermal to electrical energy. Research experience to date has shown these problems to be severe. Hence, the LLL program emphasizes development of an entirely different approach called the Total Flow concept.

  7. Resonance capture reactions with a total energy detector

    International Nuclear Information System (INIS)

    Macklin, R.L.

    1978-01-01

    The determination of nuclear reaction rates is considered; the Moxon--Rae detector and pulse height weighting are reviewed. This method has been especially useful in measuring (n,γ) cross sections. Strength functions and level spacing can be derived from (n,γ) yields. The relevance of neutron capture data to astrophysical nucleosynthesis is pointed out. The total gamma energy detection method has been applied successfully to radiative neutron capture cross section measurements. A bibliography of most of the published papers reporting neutron capture cross sections measured by the pulse height weighting technique is included. 55 references

  8. Primary power supply of repetitive pulsed intense current accelerator charged by capacitance of energy store

    International Nuclear Information System (INIS)

    Chen Jun; Yang Jianhua; Shu Ting; Zhang Jiande; Zhou Xiang; Wen Jianchun

    2008-01-01

    The primary power supply of repetitive pulsed intense current accelerator charged by capacitance of energy store is studied. The principle of primary power supply circuit and its time diagram of switches are presented. The circuit is analyzed and some expressions are got, especially, the usable voltage scope of capacitance of energy store, and the correlation between the parameters of circuit and time delay, which is between the turn-on of the charging circuit of capacitance of energy store and the circuit of recuperation. The time delay of 256 x 256 lookup table is made with the instruction of theory and the simulation of the actual parameters of circuits. The table is used by the control program to control the repetitive operating of the actual pulsed intense current accelerator. Finally, some conclusions of the primary power supply of repetitive pulsed intense current accelerator charged by capacitance of energy store are got. (authors)

  9. Carbon Capture Methods and Relative Competitiveness of Primary Energies

    International Nuclear Information System (INIS)

    Amigues, Jean-Pierre; Lafforgue, Gilles; Moreaux, Michel

    2016-01-01

    We characterise the optimal exploitation paths of two primary energies (coal and solar) that supply the energy needs of two sectors. Sector 1 can reduce its carbon emissions at a reasonable cost thanks to a CCS device. Sector 2 has access only to air capture technology, but at a significantly higher cost. We assume that the atmospheric carbon stock cannot exceed a given ceiling. We show that the optimal approach consists in, first, fully capturing sector-1 emissions before the ceiling is reached and, second, deploying air capture to partially abate sector-2 emissions. The optimal carbon tax should increase in the pre-ceiling phase then decline in stages to zero

  10. Variation in the cost of care for primary total knee arthroplasties.

    Science.gov (United States)

    Haas, Derek A; Kaplan, Robert S

    2017-03-01

    The study examined the cost variation across 29 high-volume US hospitals and their affiliated orthopaedic surgeons for delivering a primary total knee arthroplasty without major complicating conditions. The hospitals had similar patient demographics, and more than 80% of them had statistically-similar Medicare risk-adjusted readmission and complication rates. Hospital and physician personnel costs were calculated using time-driven activity-based costing. Consumable supply costs, such as the prosthetic implant, were calculated using purchase prices, and postacute care costs were measured using either internal costs or external claims as reported by each hospital. Despite having similar patient demographics and readmission and complication rates, the average cost of care for total knee arthroplasty across the hospitals varied by a factor of about 2 to 1. Even after adjusting for differences in internal labor cost rates, the hospital at the 90th percentile of cost spent about twice as much as the one at the 10th percentile of cost. The large variation in costs among sites suggests major and multiple opportunities to transfer knowledge about process and productivity improvements that lower costs while simultaneously maintaining or improving outcomes.

  11. Energy in Croatia, Annual Energy Report

    International Nuclear Information System (INIS)

    2001-12-01

    The review, in its own recognisable way, consists of the most recent and settled data for the year 2001, i.e. for the period from 1996 until 2001. We have, however, added data appertaining to a longer time period together with future expectations with the aim of an easier insight into long-term prospects. In 2001 total primary energy supply increased by 3.3 percent compared to the preceding year. Owing to the simultaneous growth of the gross domestic product by 4.1 percent, energy intensity decreased and consequently a positive trend continues. Energy intensity, which expressed the total energy consumed per unit of gross domestic product, exceeds the realised level of the developed European countries, but it is still more favourable than in the majority of transition countries. We would particularly like to stress the fact about the recorded growth of primary energy production by 7 percent, which in 2001 occurred partly as the consequence of favourable hydrological conditions and partly of a considerable increase in natural gas production. Supply from own sources grew to 52.8 percent. In 2001, natural gas production in the structure of the domestic production amounted to more than 36 percent. Energy import recorded an increase of 2.2 percent, whereby the portion of the imported crude oil was 65 percent. In 2001 transformation losses increased by 15.9 percent, transportation and distribution losses by 22.6 percent, energy sector own use by 10.3 percent, while non-energy consumption decreased by 15 percent. This brought about the situation that, together with the above mentioned growth of the total energy consumed of 3.3 percent, final demand grew by 2.6 percent - 2.3 percent in other sectors, 1.1 percent in traffic with the simultaneous increase in industry of 5.1 percent. Apart from these data, the publication comprises other interesting facts about our energy system, its capacities, energy source prices and environmental impact

  12. Energy implications of mechanical and mechanical–biological treatment compared to direct waste-to-energy

    International Nuclear Information System (INIS)

    Cimpan, Ciprian; Wenzel, Henrik

    2013-01-01

    Highlights: • Compared systems achieve primary energy savings between 34 and 140 MJ primary /100 MJ input waste. • Savings magnitude is foremost determined by chosen primary energy and materials production. • Energy consumption and process losses can be upset by increased technology efficiency. • Material recovery accounts for significant shares of primary energy savings. • Direct waste-to-energy is highly efficient if cogeneration (CHP) is possible. - Abstract: Primary energy savings potential is used to compare five residual municipal solid waste treatment systems, including configurations with mechanical (MT) and mechanical–biological (MBT) pre-treatment, which produce waste-derived fuels (RDF and SRF), biogas and/or recover additional materials for recycling, alongside a system based on conventional mass burn waste-to-energy and ash treatment. To examine the magnitude of potential savings we consider two energy efficiency levels (state-of-the-art and best available technology), the inclusion/exclusion of heat recovery (CHP vs. PP) and three different background end-use energy production systems (coal condensing electricity and natural gas heat, Nordic electricity mix and natural gas heat, and coal CHP energy quality allocation). The systems achieved net primary energy savings in a range between 34 and 140 MJ primary /100 MJ input waste , in the different scenario settings. The energy footprint of transportation needs, pre-treatment and reprocessing of recyclable materials was 3–9.5%, 1–18% and 1–8% respectively, relative to total energy savings. Mass combustion WtE achieved the highest savings in scenarios with CHP production, nonetheless, MBT-based systems had similarly high performance if SRF streams were co-combusted with coal. When RDF and SRF was only used in dedicated WtE plants, MBT-based systems totalled lower savings due to inherent system losses and additional energy costs. In scenarios without heat recovery, the biodrying MBS

  13. Energy implications of mechanical and mechanical–biological treatment compared to direct waste-to-energy

    Energy Technology Data Exchange (ETDEWEB)

    Cimpan, Ciprian, E-mail: cic@kbm.sdu.dk; Wenzel, Henrik

    2013-07-15

    Highlights: • Compared systems achieve primary energy savings between 34 and 140 MJ{sub primary}/100 MJ{sub input} {sub waste.} • Savings magnitude is foremost determined by chosen primary energy and materials production. • Energy consumption and process losses can be upset by increased technology efficiency. • Material recovery accounts for significant shares of primary energy savings. • Direct waste-to-energy is highly efficient if cogeneration (CHP) is possible. - Abstract: Primary energy savings potential is used to compare five residual municipal solid waste treatment systems, including configurations with mechanical (MT) and mechanical–biological (MBT) pre-treatment, which produce waste-derived fuels (RDF and SRF), biogas and/or recover additional materials for recycling, alongside a system based on conventional mass burn waste-to-energy and ash treatment. To examine the magnitude of potential savings we consider two energy efficiency levels (state-of-the-art and best available technology), the inclusion/exclusion of heat recovery (CHP vs. PP) and three different background end-use energy production systems (coal condensing electricity and natural gas heat, Nordic electricity mix and natural gas heat, and coal CHP energy quality allocation). The systems achieved net primary energy savings in a range between 34 and 140 MJ{sub primary}/100 MJ{sub input} {sub waste}, in the different scenario settings. The energy footprint of transportation needs, pre-treatment and reprocessing of recyclable materials was 3–9.5%, 1–18% and 1–8% respectively, relative to total energy savings. Mass combustion WtE achieved the highest savings in scenarios with CHP production, nonetheless, MBT-based systems had similarly high performance if SRF streams were co-combusted with coal. When RDF and SRF was only used in dedicated WtE plants, MBT-based systems totalled lower savings due to inherent system losses and additional energy costs. In scenarios without heat

  14. Declining primary energy consumption in nine countries of the European Community in 1980

    International Nuclear Information System (INIS)

    Gabel, R.

    1981-01-01

    The Statistical Office of the European Communities has published preliminary figures for energy consumption in the Community (of the Nine) for the year 1980. These show a primary energy consumption for the EEC in 1980 of approx. 1344 mtce. That is 63 mtce or 4.5% less than in the previous year. Primary energy consumption in 1980 still bore comparison, to some extent, with the previous record figures for 1973, the last 'normal year' before the first crisis. The figures for all the Community countries show that the energy policy measures introduced in recent years are becoming more effective, particularly the attempts to restrict oil consumption. There is also the effect of oil prices, which again rose dramatically in 1979/80. Whether this decline in consumption will continue in the future will only become clear when the promised economic upturn arrives. (orig./UA) [de

  15. Radiation damage in materials. Primary knock-on atom energy analyses of cascade damage

    International Nuclear Information System (INIS)

    Sekimura, Naoto

    1995-01-01

    To understand cascade damage formation as a function of primary recoil energy, thin foils of gold were irradiated with 20 - 400 keV self-ions to 1.0 x 10 14 ions/m 2 at 300 K. Yield of groups of vacancy clusters saturated at ion energy higher than 100 keV. Number of clusters in a group had variation even from the same energy ions. Size distribution of the clusters was not strongly dependent on number of clusters in a group and ion energy. Density of vacancy clusters in a group formed near the specimen surface was calibrated to estimate vacancy cluster formation in neutron-irradiated material. A model was proposed to predict distribution of defect clusters in the irradiated materials based on a primary recoil spectrum. Examples of recomposed distribution of vacancy clusters in a group in irradiated gold were compared with the measured data. (author)

  16. Energy conservation in the primary aluminum and chlor-alkali industries

    Energy Technology Data Exchange (ETDEWEB)

    1980-10-01

    The primary aluminum and chlor-alkali industries together use nearly 13% of the electrical energy consumed by US industry. As part of its mission to promote energy conservation in basic US industries, the DOE surveys the present technological status of the major electrochemical industries and evaluates promising technological innovations that may lead to reduced energy requirements. This study provides technical and economic analyses in support of a government program of research and development in advanced electrolytic technology. This program is intended to supplement the development efforts directed toward energy savings by private industry. Sections II and III of this report cover aluminum and chlorine production processes only, since these two industries represent over 90% of the electrical energy requirements of all electrolytic industries in the United States. Section IV examines barriers to accelerated research and development by the electrolytic industries, and makes suggestions for government actions to overcome these barriers.

  17. Phase change thermal storage for a solar total energy system

    Science.gov (United States)

    Rice, R. E.; Cohen, B. M.

    1978-01-01

    An analytical and experimental program is being conducted on a one-tenth scale model of a high-temperature (584 K) phase-change thermal energy storage system for installation in a solar total energy test facility at Albuquerque, New Mexico, U.S.A. The thermal storage medium is anhydrous sodium hydroxide with 8% sodium nitrate. The program will produce data on the dynamic response of the system to repeated cycles of charging and discharging simulating those of the test facility. Data will be correlated with a mathematical model which will then be used in the design of the full-scale system.

  18. The Energy Effectiveness Of Crops In Crop Rotation Under Different Soil Tillage Systems

    Directory of Open Access Journals (Sweden)

    Strašil Zdeněk

    2015-09-01

    Full Text Available The paper identifies and compares the energy balance of winter wheat, spring barley and white mustard – all grown in crop rotation under different tillage conditions. The field trial included the conventional tillage (CT method, minimum tillage (MT and a system with no tillage (NT. The energy inputs included both the direct and indirect energy component. Energy outputs are evaluated as gross calorific value (gross heating value of phytomass dry matter of the primary product and the total harvested production. The energy effectiveness (energy output: energy input was selected for evaluation. The greatest energy effectiveness for the primary product was established as 6.35 for barley, 6.04 for wheat and 3.68 for mustard; in the case of total production, it was 9.82 for barley, 10.08 for wheat and 9.72 for mustard. When comparing the different tillage conditions, the greatest energy effectiveness was calculated for the evaluated crops under the MT operation and represented the primary product of wheat at 6.49, barley at 6.69 and mustard at 3.92. The smallest energy effectiveness for the primary product was found in wheat 5.77 and barley 6.10 under the CT option; it was 3.55 for mustard under the option of NT. Throughout the entire cropping pattern, the greatest energy effectiveness was established under the minimum tillage option – 5.70 for the primary product and 10.47 for the total production. On the other hand, the smallest values were calculated under CT – 5.22 for the primary product and 9.71 for total production.

  19. Forward elastic scattering and total cross-section at very high energies

    International Nuclear Information System (INIS)

    Castaldi, R.

    1985-01-01

    The successful cooling technique of antiproton beams at CERN has recently allowed the acceleration of proton and antiproton bunches simultaneously circulating in opposite directions in the SPS. Hadron-hadron collisions could so be produced at a centre-of-mass energy one order of magnitude higher than previously available, thus opening a new wide range of energies to experimentation. This technique also made it possible to replace one of the two proton beams in the ISR by a beam of antiprotons, allowing a direct precise comparison, by the same detectors, of pp and anti pp processes at the same energies. The recent results are summarized of the forward elastic scattering and total cross-section in this new energy domain. (Mori, K.)

  20. Primary defect production by high energy displacement cascades in molybdenum

    Energy Technology Data Exchange (ETDEWEB)

    Selby, Aaron P. [Department of Nuclear Engineering, University of Tennessee, Knoxville, TN 37996 (United States); Xu, Donghua, E-mail: xudh@utk.edu [Department of Nuclear Engineering, University of Tennessee, Knoxville, TN 37996 (United States); Juslin, Niklas; Capps, Nathan A. [Department of Nuclear Engineering, University of Tennessee, Knoxville, TN 37996 (United States); Wirth, Brian D. [Department of Nuclear Engineering, University of Tennessee, Knoxville, TN 37996 (United States); Oak Ridge National Laboratory, P.O. Box 2008, MS6003, Oak Ridge, TN 37831 (United States)

    2013-06-15

    We report molecular dynamics simulations of primary damage in molybdenum produced by high energy displacement cascades on the femto- to pico-second and Angstrom to nanometer scales. Clustering directly occurred for both interstitials and vacancies in the 1–50 keV cascade energy range explored. Point defect survival efficiency and partitioning probabilities into different sized clusters were quantified. The results will provide an important reference for kinetic models to describe the microstructural evolution in Mo under ion or neutron irradiations over much longer time and length scales.

  1. Activities Contributing to Total Energy Expenditure in the United States: Results from the NHAPS Study

    Directory of Open Access Journals (Sweden)

    Block Gladys

    2004-02-01

    Full Text Available Abstract Background Physical activity is increasingly recognized as an important factor influencing health and disease status. Total energy expenditure, both low-intensity and high-intensity, contributes to maintenance of healthy body weight. This paper presents the results of a quantitative approach to determining the activities that contribute to total energy expenditure in the United States. Methods Data from the National Human Activity Pattern Survey (NHAPS were used. In 1992–1994 the NHAPS sampled 4,185 females and 3,330 males, aged 18 years and over, weighted to be representative of the 48 contiguous United States. A detailed report of each activity performed in the previous 24 hours was obtained. A score was created for each activity, by multiplying duration and intensity for each individual and summing across individuals. This score was then used to rank each activity according to its contribution to total population energy expenditure, for the total sample and separately for each gender, race, age, region, and season. Results This analysis reveals our society to be primarily sedentary; leisure time physical activity contributed only approximately 5% of the population's total energy expenditure. Not counting sleeping, the largest contributor to energy expenditure was "Driving a car", followed by "Office work" and "Watching TV". Household activities accounted for 20.1% and 33.3% of energy expenditure for males and females respectively. Conclusion The information presented in this paper may be useful in identifying common activities that could be appropriate targets for behavioral interventions to increase physical activity.

  2. An energy balance and greenhouse gas profile for county Wexford, Ireland in 2006

    International Nuclear Information System (INIS)

    Curtin, Richard

    2011-01-01

    Highlights: → Residential sector emits 38% of total CO 2 emissions. → Transport and industry/commerce sectors emit 28% each. → Oil composes 91% of total primary energy requirement (TPER). → Methane accounts for 25% of total greenhouse gas emissions. → Agriculture accounts for 36% of total greenhouse gas emissions. -- Abstract: In this paper an energy balance and a greenhouse gas profile has been formulated for the county of Wexford, situated in the south east of Ireland. The energy balance aims to aggregate all energy consumption in the county for the year 2006 across the following sectors; residential, agriculture, commerce and industry, and transport. The results of the energy balance are compared with the previous energy balance of 2001 where it is found that the residential sector is the biggest emitter of CO 2 with 38% of total emissions with the transport and industry/commerce sectors sharing second place on 28%. Consumption of oil is seen to have increased significantly in nearly all sectors, accounting for over 70% of the total final energy consumed (TFC) while the total primary energy requirement (TPER) sees oil consumption accounting for 91% of all fuels consumed. To take into account the contribution of agriculture in total GHG emissions the gases CH 4 and N 2 O will be estimated from the agricultural and waste sectors. The results show that methane contributes 25% of total GHG emissions with agriculture being the primary contributor accounting for 36% of total emissions.

  3. Total Corporate social responsibility report 2004. Sharing our energy

    International Nuclear Information System (INIS)

    2005-05-01

    This document presents the social and environmental activities of the group Total for the year 2004. It provides information on the ethical aspects of the governance, the industrial security, the environmental policy, the public health and the occupational safety, the social liability and the economical and social impact of the group activities in the local development, the contribution to the climatic change fight and the development of other energy sources. (A.L.B.)

  4. Energy in Croatia 2009, Annual Energy Report

    International Nuclear Information System (INIS)

    2010-01-01

    With the eighteenth edition of the Review Energy in Croatia, Ministry of Economy, Labour and Entrepreneurship continues the practice of informing domestic and foreign public on relations and trends within the Croatian energy sector. This Review gives, in a recognizable and comprehensible way, data and characteristic values relevant to the Croatian energy sector, providing an overview on energy production and consumption at all levels. There is a detailed analysis of the trends present in the energy sector as well as a number of information on capacities, reserves, prices and energy balances for crude oil, all petroleum products, natural gas, electricity, heat energy, coal and renewable energy sources. The Review also brings the main economic and financial indicators, data on air pollutant emissions and main energy efficiancy indicators. It also gives the ODEX energy efficiancy index, which is determined according to the methodology used in the European Union. This indicator monitors the energy efficiancy trends over a period of time in the sectors of industry, transport, households and in total consumption. Finally, the Review brings the energy balances of the Republic of Croatia for the years 2008 and 2009, made following the EUROSTAT and IEA methodologies. In 2009 total energy demand in Croatia was 1.6 percent lower than the year before. At the same time, gross domestic product fell by 5.8 percent, which as a result gave a 4.4 percent higher level of energy intensity in total energy consumption. When compared to the average energy intensity level in the EU (EU27), the energy intensity in Croatia was 6.8 percent higher. The primary energy production in 2009 was 7.1 percent higher form the previous year. Also, due to favorable hydrological situation the hydropower utilization grew by 31 percent. The energy from renewable sources increased by 29.8 percent and the energy from fuel wood increased by 5.6 percent. The production of crude oil in 2009 decreased by 6

  5. Modeling primary energy substitution in the Asia Pacific

    International Nuclear Information System (INIS)

    Aguilera, Roberto F.; Ripple, Ronald D.

    2013-01-01

    Highlights: • We model the market shares (i.e. energy mix) of gases, liquids and solids in the Asia Pacific. • The model matches the historical energy mix and projects three scenarios of the future mix to 2030. • We then model the past and future hydrogen to carbon ratio (a proxy for environmental quality). • Importance of natural gas in the region could increase significantly, depending on policy and tech progress. - Abstract: A Global Energy Market model (GEM) is used to analyze the market shares (i.e. the primary energy mix) of gases, liquids and solids in the Asia Pacific. The model is successful in matching the historical energy mix from 1850 to 2009. The model also provides a good match of the hydrogen to carbon ratio, which is a proxy for environmental quality. Given these validations, the GEM is then used to present scenarios of the Asia Pacific energy mix and hydrogen to carbon ratio until the year 2030. Three energy mix scenarios are presented – reference case; alternative case 1; alternative case 2. The reference case assumes limited divergence from current policies and technologies. It indicates that Asia Pacific energy needs will be met by approximately 46% solids, 34% liquids, and 20% gases by 2030. Alternative cases 1 and 2 represent policies and technologies that either encourage or discourage the use of gases. The good matches observed for historical data suggest the GEM can be used cautiously for evaluating outcomes and opportunities in the region. Although the model can be used for projecting far into the future, it is currently calibrated to what we consider a reasonable time horizon – until the year 2030. Given appropriate energy policies and sufficient technological advancement, the importance of natural gas in the region could increase significantly

  6. Mechanical properties of carbynes investigated by ab initio total-energy calculations

    DEFF Research Database (Denmark)

    Castelli, Ivano E.; Salvestrini, Paolo; Manini, Nicola

    2012-01-01

    As sp carbon chains (carbynes) are relatively rigid molecular objects, can we exploit them as construction elements in nanomechanics? To answer this question, we investigate their remarkable mechanical properties by ab initio total-energy simulations. In particular, we evaluate their linear...

  7. Changes in Energy Cost and Total External Work of Muscles in Elite Race Walkers Walking at Different Speeds

    Directory of Open Access Journals (Sweden)

    Chwała Wiesław

    2014-12-01

    Full Text Available The aim of the study was to assess energy cost and total external work (total energy depending on the speed of race walking. Another objective was to determine the contribution of external work to total energy cost of walking at technical, threshold and racing speed in elite competitive race walkers.

  8. Achievement report for fiscal 1982 on Sunshine Program-entrusted research and development. Research on hydrogen energy total system; 1982 nendo suiso energy total system no kenkyu seika hokokusho

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1983-03-01

    In this research on a hydrogen energy total system, studies are conducted on the plan of a hydrogen energy proving pilot base and on hydrogen as fuel for automobiles. It is estimated that the construction of a hydrogen energy proving pilot base will cost 7.125-billion yen in total. The sum includes 6.410-billion yen for the construction of a system on an island named Island A, 500-million yen for structures on an island named Island B, and 215-million yen for the construction of a marine transportation system between the two islands. Large shares will go to a hydroelectric power plant and a hydrogen liquefaction system, the two occupying approximately half of the total sum. In the study of hydrogen as fuel for automobiles, it is concluded that hydrogen is advantageously employed as fuel for automobiles. When comparison is made in terms of heat value, it is found that even a hydrogen engine which is a mere modification of a currently used engine is comparable to the currently used engine in terms of performance. As for abnormal combustion, a hydrogen/air 2-system injection method is contrived, and this solves the problem almost completely. Cryogenic hydrogen is advantageous in both NOx emission and heat efficiency though within certain limitations. From the viewpoint of safety, the recommended automobile fuel structural formula is GH{sub 2}(MH). (NEDO)

  9. Comparison of topical versus intravenous tranexamic acid in primary total knee arthroplasty: a meta-analysis of randomized controlled and prospective cohort trials.

    Science.gov (United States)

    Wang, Hao; Shen, Bin; Zeng, Yi

    2014-12-01

    There has been much debate and controversy about the optimal regimen of tranexamic acid in primary total knee arthroplasty. The purpose of this study was to undertake a meta-analysis to compare the efficacy of topical and intravenous regimen of tranexamic acid in primary total knee arthroplasty. A systematic review of the electronic databases PubMed, CENTRAL, Web of Science, and Embase was undertaken. All randomized controlled trials and prospective cohort studies evaluating the effectiveness of topical and intravenous tranexamic acid during primary total knee arthroplasty were included. The focus of the analysis was on the outcomes of blood loss, transfusion rate, and thromboembolic complications. Subgroup analysis was performed when possible. Of 328 papers identified, six trials were eligible for data extraction and meta-analysis comprising 679 patients (739 knees). We found no statistically significant difference between topical and intravenous administration of tranexamic acid in terms of blood loss, transfusion requirements and thromboembolic complications. Topical tranexamic acid has a similar efficacy to intravenous tranexamic acid in reducing both blood loss and transfusion rate without sacrificing safety in primary total knee arthroplasty. II. Copyright © 2014 Elsevier B.V. All rights reserved.

  10. A comment on the calculation of the total-factor energy efficiency (TFEE) index

    International Nuclear Information System (INIS)

    Chang, Ming-Chung

    2013-01-01

    This study provides a no-output growth model to conveniently calculate the total-factor energy efficiency (TFEE) index originally proposed by Hu and Wang (2006). The TFEE index serves as a very well-known and popular means of estimating overall energy efficiency. While many previous studies have used the indicator of energy inefficiency, including the indicator of energy intensity (i.e., Energy input/Gross Domestic Product (GDP)) to measure energy efficiency, Hu and Kao (2007) point out that the indicator of energy intensity is not only a partial-factor energy efficiency indicator, but that this partial-factor ratio is also quite inappropriate for analyzing the impact of changing energy use over time. The TFEE index overcomes the disadvantage of the indicator of energy intensity as mentioned above, but five steps are needed to calculate the TFEE score. In this study, we provide a no-output growth model to conveniently calculate the TFEE score. Furthermore, we extend this no-output growth model to an output growth model. This study concludes that the output growth model not only makes it easier to calculate the TFEE index than the model proposed by Hu and Wang (2006) and Hu and Kao (2007), but that it can also obtain better TFEE scores. - Highlights: ► The comment is on the total-factor energy efficiency (TFEE) index. ► Two extension models are no-output growth model and output growth model. ► The model in this study makes it easier to calculate the TFEE index.

  11. Institutional applications of solar total-energy systems. Draft final report. Volume 2. Appendixes

    Energy Technology Data Exchange (ETDEWEB)

    None

    1978-07-01

    The appendices present the analytical basis for the analysis of solar total energy (STE) systems. A regional-climate model and a building-load requirements model are developed, along with fuel-price scenarios. Life-cycle costs are compared for conventional-utility, total energy, and STE systems. Thermal STE system design trade-offs are performed and thermal STE system performance is determined. The sensitivity of STE competitiveness to fuel prices is examined. The selection of the photovoltaic array is briefly discussed. The institutional-sector decision processes are analyzed. Hypothetical regional back-up rates and electrical-energy costs are calculated. The algorithms and equations used in operating the market model are given, and a general methodology is developed for projecting the size of the market for STE systems and applied to each of 8 institutional subsectors. (LEW)

  12. Improving the Energy Performance in Existing Non-residential Buildings in Denmark Using the Total Concept Method

    DEFF Research Database (Denmark)

    Krawczyk, Pawel; Afshari, Alireza; Simonsen, Graves K.

    2016-01-01

    This project is a part of a joint European research project, “Total Concept”, which is a method for improving the energy performance in existing non-Residential buildings. The method focuses on achieving maximum energy savings in a Building within the profitability frames set by a building owner...... was to form a package of measures for an energy performance improvement in the building based on the Total Concept method. This paper presents results from recently analyzed data on two renovated Danish buildings according to the rules of “Total Concept” method. According to the estimation done based...

  13. Estimation of the energy ratio between primary and ambience components in stereo audio data

    NARCIS (Netherlands)

    Harma, A.S.

    2011-01-01

    Stereo audio signal is often modeled as a mixture of instantaneously mixed primary components and uncorrelated ambience components. This paper focuses on the estimation of the primary-to-ambience energy ratio, PAR. This measure is useful for signal decomposition in stereo and multichannel audio

  14. The total kinetic energy release in the fast neutron-induced fission of {sup 232}Th

    Energy Technology Data Exchange (ETDEWEB)

    King, Jonathan; Yanez, Ricardo; Loveland, Walter; Barrett, J. Spencer; Oscar, Breland [Oregon State University, Dept. of Chemistry, Corvallis, OR (United States); Fotiades, Nikolaos; Tovesson, Fredrik; Young Lee, Hye [Los Alamos National Laboratory, Physics Division, Los Alamos, NM (United States)

    2017-12-15

    The post-emission total kinetic energy release (TKE) in the neutron-induced fission of {sup 232}Th was measured (using white spectrum neutrons from LANSCE) for neutron energies from E{sub n} = 3 to 91 MeV. In this energy range the average post-neutron total kinetic energy release decreases from 162.3 ± 0.3 at E{sub n} = 3 MeV to 154.9 ± 0.3 MeV at E{sub n} = 91 MeV. Analysis of the fission mass distributions indicates that the decrease in TKE with increasing neutron energy is a combination of increasing yields of symmetric fission (which has a lower associated TKE) and a decrease in the TKE release in asymmetric fission. (orig.)

  15. Changes in Intakes of Total and Added Sugar and their Contribution to Energy Intake in the U.S.

    Directory of Open Access Journals (Sweden)

    Won O. Song

    2010-08-01

    Full Text Available This study was designed to document changes in total sugar intake and intake of added sugars, in the context of total energy intake and intake of nutrient categories, between the 1970s and the 1990s, and to identify major food sources contributing to those changes in intake. Data from the NHANES I and III were analyzed to obtain nationally representative information on food consumption for the civilian, non-institutionalized population of the U.S. from 1971 to 1994. In the past three decades, in addition to the increase in mean intakes of total energy, total sugar, added sugars, significant increases in the total intake of carbohydrates and the proportion of carbohydrates to the total energy intake were observed. The contribution of sugars to total carbohydrate intake decreased in both 1–18 y and 19+ y age subgroups, and the contribution of added sugars to the total energy intake did not change. Soft drinks/fluid milk/sugars and cakes, pastries, and pies remained the major food sources for intake of total sugar, total carbohydrates, and total energy during the past three decades. Carbonated soft drinks were the most significant sugar source across the entire three decades. Changes in sugar consumption over the past three decades may be a useful specific area of investigation in examining the effect of dietary patterns on chronic diseases.

  16. Combined application versus topical and intravenous application of tranexamic acid following primary total hip arthroplasty: a meta-analysis.

    Science.gov (United States)

    Zhang, Pei; Liang, Yuan; Chen, Pengtao; Fang, Yongchao; He, Jinshan; Wang, Jingcheng

    2017-02-21

    The use of intravenous (IV) or topical tranexamic acid (TXA) in total hip arthroplasty has been proven to be effective and safe in total hip arthroplasty. However, which of these two administration routes is better has not been determined. The combined administration of TXA has been used in total knee arthroplasty with satisfactory results. We hypothesized that combined application of TXA may be the most effective way without increased rate of thrombotic events such as deep vein thrombosis (DVT) and pulmonary embolisms (PE) in patients subjected to primary total hip replacement (THA). A meta-analysis was conducted to compare the efficacy and safety of the combined use of tranexamic acid (TXA) relative to topical or intravenous (IV) use alone for treatment of primary THA. The outcomes included total blood loss, postoperative hemoglobin decline, transfusion rates, and the incidence rates of deep vein thrombosis (DVT) and pulmonary embolisms (PE). We searched electronic databases including PubMed, EMBASE, the Cochrane Library, Web of Science, the Chinese Biomedical Literature database, the CNKI database, and Wanfang Data until September 2016. The references of the included articles were also checked for additional potentially relevant studies. There were no language restrictions for the search. The data of the included studies were analyzed using RevMan 5.3 software. Seven studies met the inclusion criteria, encompassing a total of 1762 patients. Our meta-analysis demonstrated that total blood loss, postoperative hemoglobin decline, and transfusion rates were significantly lower for patients that received the combined treatment compared to patients that received either topical or intravenous administration of TXA. No statistical differences were found in the incidence of deep venous thrombosis (DVT) or pulmonary embolism (PE). The group that received the combined treatment had lower total blood loss, postoperative hemoglobin decline, and transfusion rates without an

  17. The Cost-Effectiveness of Dual Mobility Implants for Primary Total Hip Arthroplasty: A Computer-Based Cost-Utility Model.

    Science.gov (United States)

    Barlow, Brian T; McLawhorn, Alexander S; Westrich, Geoffrey H

    2017-05-03

    Dislocation remains a clinically important problem following primary total hip arthroplasty, and it is a common reason for revision total hip arthroplasty. Dual mobility (DM) implants decrease the risk of dislocation but can be more expensive than conventional implants and have idiosyncratic failure mechanisms. The purpose of this study was to investigate the cost-effectiveness of DM implants compared with conventional bearings for primary total hip arthroplasty. Markov model analysis was conducted from the societal perspective with use of direct and indirect costs. Costs, expressed in 2013 U.S. dollars, were derived from the literature, the National Inpatient Sample, and the Centers for Medicare & Medicaid Services. Effectiveness was expressed in quality-adjusted life years (QALYs). The model was populated with health state utilities and state transition probabilities derived from previously published literature. The analysis was performed for a patient's lifetime, and costs and effectiveness were discounted at 3% annually. The principal outcome was the incremental cost-effectiveness ratio (ICER), with a willingness-to-pay threshold of $100,000/QALY. Sensitivity analyses were performed to explore relevant uncertainty. In the base case, DM total hip arthroplasty showed absolute dominance over conventional total hip arthroplasty, with lower accrued costs ($39,008 versus $40,031 U.S. dollars) and higher accrued utility (13.18 versus 13.13 QALYs) indicating cost-savings. DM total hip arthroplasty ceased being cost-saving when its implant costs exceeded those of conventional total hip arthroplasty by $1,023, and the cost-effectiveness threshold for DM implants was $5,287 greater than that for conventional implants. DM was not cost-effective when the annualized incremental probability of revision from any unforeseen failure mechanism or mechanisms exceeded 0.29%. The probability of intraprosthetic dislocation exerted the most influence on model results. This model

  18. Unconstrained tripolar implants for primary total hip arthroplasty in patients at risk for dislocation.

    Science.gov (United States)

    Guyen, Olivier; Pibarot, Vincent; Vaz, Gualter; Chevillotte, Christophe; Carret, Jean-Paul; Bejui-Hugues, Jacques

    2007-09-01

    We performed a retrospective study on 167 primary total hip arthroplasty (THA) procedures in 163 patients at high risk for instability to assess the reliability of unconstrained tripolar implants (press-fit outer metal shell articulating a bipolar polyethylene component) in preventing dislocations. Eighty-four percent of the patients had at least 2 risk factors for dislocation. The mean follow-up length was 40.2 months. No dislocation was observed. Harris hip scores improved significantly. Six hips were revised, and no aseptic loosening of the cup was observed. The tripolar implant was extremely successful in achieving stability. However, because of the current lack of data documenting polyethylene wear at additional bearing, the routine use of tripolar implants in primary THA is discouraged and should be considered at the present time only for selected patients at high risk for dislocation and with limited activities.

  19. The Impact of Discharge Disposition on Episode-of-Care Reimbursement After Primary Total Hip Arthroplasty.

    Science.gov (United States)

    Sabeh, Karim G; Rosas, Samuel; Buller, Leonard T; Roche, Martin W; Hernandez, Victor H

    2017-10-01

    Total joint arthroplasty (TJA) accounts for more Medicare expenditure than any other inpatient procedure. The Comprehensive Care for Joint Replacement model was introduced to decrease cost and improve quality in TJA. The largest portion of episode-of-care costs occurs after discharge. This study sought to quantify the cost variation of primary total hip arthroplasty (THA) according to discharge disposition. The Medicare and Humana claims databases were used to extract charges and reimbursements to compare day-of-surgery and 91-day postoperative costs simulating episode-of-care reimbursements. Of the patients who underwent primary THA, 257,120 were identified (204,912 from Medicare and 52,208 from Humana). Patients were stratified by discharge disposition: home with home health, skilled nursing facility, or inpatient rehabilitation facility. There is a significant difference in the episode-of-care costs according to discharge disposition, with discharge to an inpatient rehabilitation facility the most costly and discharge to home the least costly. Postdischarge costs represent a sizeable portion of the overall expense in THA, and optimizing patients to allow safe discharge to home may help reduce the cost of THA. Copyright © 2017 Elsevier Inc. All rights reserved.

  20. The Future of Nuclear Energy As a Primary Source for Clean Hydrogen Energy System in Developing Countries

    International Nuclear Information System (INIS)

    Ahmed, K.; Shaaban, H.

    2007-01-01

    The limited availability of fossil fuels compared to the increasing demand and the connected environmental questions have become topics of growing importance and international attention. Many other clean alternative sources of energy are available, but most of them are either relatively undeveloped technologically or are not yet fully utilized. Also, there is a need for a medium which can carry the produced energy to the consumer in a convenient and environmentally acceptable way. In this study, a fission reactor as a primary energy source with hydrogen as an energy carrier is suggested. An assessment of hydrogen production from nuclear energy is presented. A complete nuclear-electro-hydrogen energy system is proposed for a medium size city (population of 500,000). The whole energy requirement is assessed including residential, industrial and transportation energies. A preliminary economical and environmental impact study is performed on the proposed system. The presented work could be used as a nucleus for a feasibility study for applying this system in any newly established city

  1. Global patterns in human consumption of net primary production

    Science.gov (United States)

    Imhoff, Marc L.; Bounoua, Lahouari; Ricketts, Taylor; Loucks, Colby; Harriss, Robert; Lawrence, William T.

    2004-06-01

    The human population and its consumption profoundly affect the Earth's ecosystems. A particularly compelling measure of humanity's cumulative impact is the fraction of the planet's net primary production that we appropriate for our own use. Net primary production-the net amount of solar energy converted to plant organic matter through photosynthesis-can be measured in units of elemental carbon and represents the primary food energy source for the world's ecosystems. Human appropriation of net primary production, apart from leaving less for other species to use, alters the composition of the atmosphere, levels of biodiversity, energy flows within food webs and the provision of important ecosystem services. Here we present a global map showing the amount of net primary production required by humans and compare it to the total amount generated on the landscape. We then derive a spatial balance sheet of net primary production `supply' and `demand' for the world. We show that human appropriation of net primary production varies spatially from almost zero to many times the local primary production. These analyses reveal the uneven footprint of human consumption and related environmental impacts, indicate the degree to which human populations depend on net primary production `imports' and suggest policy options for slowing future growth of human appropriation of net primary production.

  2. Total reflection coefficients of low-energy photons presented as universal functions

    Directory of Open Access Journals (Sweden)

    Ljubenov Vladan

    2010-01-01

    Full Text Available The possibility of expressing the total particle and energy reflection coefficients of low-energy photons in the form of universal functions valid for different shielding materials is investigated in this paper. The analysis is based on the results of Monte Carlo simulations of photon reflection by using MCNP, FOTELP, and PENELOPE codes. The normal incidence of the narrow monoenergetic photon beam of the unit intensity and of initial energies from 20 keV up to 100 keV is considered, and particle and energy reflection coefficients from the plane homogenous targets of water, aluminum, and iron are determined and compared. The representations of albedo coefficients on the initial photon energy, on the probability of large-angle photon scattering, and on the mean number of photon scatterings are examined. It is found out that only the rescaled albedo coefficients dependent on the mean number of photon scatterings have the form of universal functions and these functions are determined by applying the least square method.

  3. Seasonal variation of total particulate matter and children respiratory diseases at Lisbon primary schools using passive methods

    NARCIS (Netherlands)

    Canha, N.; Almeida, M.; Do Carmo Freitas, M.; Almeida, S.M.; Wolterbeek, H.T.

    2011-01-01

    In this work, 14 primary schools of Lisbon city, Portugal, followed a questionnaire of the ISAAC - International Study of Asthma and Allergies in Childhood Program, in 2009/2010. The questionnaire contained questions to identify children with respiratory diseases (wheeze, asthma and rhinitis). Total

  4. Fission fragment mass and total kinetic energy distributions of spontaneously fissioning plutonium isotopes

    Science.gov (United States)

    Pomorski, K.; Nerlo-Pomorska, B.; Bartel, J.; Schmitt, C.

    2018-03-01

    The fission-fragment mass and total kinetic energy (TKE) distributions are evaluated in a quantum mechanical framework using elongation, mass asymmetry, neck degree of freedom as the relevant collective parameters in the Fourier shape parametrization recently developed by us. The potential energy surfaces (PES) are calculated within the macroscopic-microscopic model based on the Lublin-Strasbourg Drop (LSD), the Yukawa-folded (YF) single-particle potential and a monopole pairing force. The PES are presented and analysed in detail for even-even Plutonium isotopes with A = 236-246. They reveal deep asymmetric valleys. The fission-fragment mass and TKE distributions are obtained from the ground state of a collective Hamiltonian computed within the Born-Oppenheimer approximation, in the WKB approach by introducing a neck-dependent fission probability. The calculated mass and total kinetic energy distributions are found in good agreement with the data.

  5. Comparison of stress and total energy methods for calculation of elastic properties of semiconductors.

    Science.gov (United States)

    Caro, M A; Schulz, S; O'Reilly, E P

    2013-01-16

    We explore the calculation of the elastic properties of zinc-blende and wurtzite semiconductors using two different approaches: one based on stress and the other on total energy as a function of strain. The calculations are carried out within the framework of density functional theory in the local density approximation, with the plane wave-based package VASP. We use AlN as a test system, with some results also shown for selected other materials (C, Si, GaAs and GaN). Differences are found in convergence rate between the two methods, especially in low symmetry cases, where there is a much slower convergence for total energy calculations with respect to the number of plane waves and k points used. The stress method is observed to be more robust than the total energy method with respect to the residual error in the elastic constants calculated for different strain branches in the systems studied.

  6. Projection potentials and angular momentum convergence of total energies in the full-potential Korringa–Kohn–Rostoker method

    International Nuclear Information System (INIS)

    Zeller, Rudolf

    2013-01-01

    Although the full-potential Korringa–Kohn–Rostoker Green function method yields accurate results for many physical properties, the convergence of calculated total energies with respect to the angular momentum cutoff is usually considered to be less satisfactory. This is surprising because accurate single-particle energies are expected if they are calculated by Lloyd’s formula and because accurate densities and hence accurate double-counting energies should result from the total energy variational principle. It is shown how the concept of projection potentials can be used as a tool to analyse the convergence behaviour. The key factor blocking fast convergence is identified and it is illustrated how total energies can be improved with only a modest increase of computing time. (paper)

  7. Regional total factor energy efficiency: An empirical analysis of industrial sector in China

    International Nuclear Information System (INIS)

    Wang, Zhao-Hua; Zeng, Hua-Lin; Wei, Yi-Ming; Zhang, Yi-Xiang

    2012-01-01

    Highlights: ► We evaluate energy efficiency under framework of total factor energy efficiency. ► We focus on industry sector of China. ► We use statistical data of industrial enterprises above designated size. ► Energy efficiencies among regions in China are obvious because of technological differences. ► Large scale of investment should be stopped especially in central and western regions. -- Abstract: The rapid growth of the Chinese economy has resulted in great pressure on energy consumption, especially the energy intensive sector – the industrial sector. To achieve sustainable development, China has to consider how to promote energy efficiency to meet the demand of Chinese rapid economic growth, as the energy efficiency of China is relatively low. Meanwhile, the appeal of energy saving and emission reduction has been made by the Chinese central government. Therefore, it is important to evaluate the energy efficiency of industrial sector in China and to assess efficiency development probabilities. The framework of total factor energy efficiency index is adopted to determine the discrepancy of energy efficiency in Chinese industrial sector based on the provincial statistical data of industrial enterprises above designated size in 30 provinces from 2005 to 2009, with gross industrial output as the output value and energy consumption, average remaining balance of capital assets and average amount of working force as the input values. Besides, in considerate of the regional divide of China, namely eastern, central, and western, and economic development differences in each region, energy efficiency of each region is also analysed in this paper. The results show that there is room for China to improve its energy efficiency, especially western provinces which have large amount of energy input excess. Generally speaking, insufficient technological investment and fail of reaching best scale of manufacture are two factors preventing China from energy

  8. An updated h-index measures both the primary and total scientific output of a researcher.

    Science.gov (United States)

    Bucur, Octavian; Almasan, Alex; Zubarev, Roman; Friedman, Mark; Nicolson, Garth L; Sumazin, Pavel; Leabu, Mircea; Nikolajczyk, Barbara S; Avram, Dorina; Kunej, Tanja; Calin, George A; Godwin, Andrew K; Adami, Hans-Olov; Zaphiropoulos, Peter G; Richardson, Des R; Schmitt-Ulms, Gerold; Westerblad, Håkan; Keniry, Megan; Grau, Georges E R; Carbonetto, Salvatore; Stan, Radu V; Popa-Wagner, Aurel; Takhar, Kasumov; Baron, Beverly W; Galardy, Paul J; Yang, Feng; Data, Dipak; Fadare, Oluwole; Yeo, Kt Jerry; Gabreanu, Georgiana R; Andrei, Stefan; Soare, Georgiana R; Nelson, Mark A; Liehn, Elisa A

    2015-01-01

    The growing interest in scientometry stems from ethical concerns related to the proper evaluation of scientific contributions of an author working in a hard science. In the absence of a consensus, institutions may use arbitrary methods for evaluating scientists for employment and promotion. There are several indices in use that attempt to establish the most appropriate and suggestive position of any scientist in the field he/she works in. A scientist's Hirsch-index (h-index) quantifies their total effective published output, but h-index summarizes the total value of their published work without regard to their contribution to each publication. Consequently, articles where the author was a primary contributor carry the same weight as articles where the author played a minor role. Thus, we propose an updated h-index named Hirsch(p,t)-index that informs about both total scientific output and output where the author played a primary role. Our measure, h(p,t) = h(p),h(t), is composed of the h-index h(t) and the h-index calculated for articles where the author was a key contributor; i.e. first/shared first or senior or corresponding author. Thus, a h(p,t) = 5,10 would mean that the author has 5 articles as first, shared first, senior or corresponding author with at least 5 citations each, and 10 total articles with at least 10 citations each. This index can be applied in biomedical disciplines and in all areas where the first and last position on an article are the most important. Although other indexes, such as r- and w-indexes, were proposed for measuring the authors output based on the position of researchers within the published articles, our simpler strategy uses the already established algorithms for h-index calculation and may be more practical to implement.

  9. Scatter correction method with primary modulator for dual energy digital radiography: a preliminary study

    Science.gov (United States)

    Jo, Byung-Du; Lee, Young-Jin; Kim, Dae-Hong; Jeon, Pil-Hyun; Kim, Hee-Joung

    2014-03-01

    In conventional digital radiography (DR) using a dual energy subtraction technique, a significant fraction of the detected photons are scattered within the body, resulting in the scatter component. Scattered radiation can significantly deteriorate image quality in diagnostic X-ray imaging systems. Various methods of scatter correction, including both measurement and non-measurement-based methods have been proposed in the past. Both methods can reduce scatter artifacts in images. However, non-measurement-based methods require a homogeneous object and have insufficient scatter component correction. Therefore, we employed a measurement-based method to correct for the scatter component of inhomogeneous objects from dual energy DR (DEDR) images. We performed a simulation study using a Monte Carlo simulation with a primary modulator, which is a measurement-based method for the DEDR system. The primary modulator, which has a checkerboard pattern, was used to modulate primary radiation. Cylindrical phantoms of variable size were used to quantify imaging performance. For scatter estimation, we used Discrete Fourier Transform filtering. The primary modulation method was evaluated using a cylindrical phantom in the DEDR system. The scatter components were accurately removed using a primary modulator. When the results acquired with scatter correction and without correction were compared, the average contrast-to-noise ratio (CNR) with the correction was 1.35 times higher than that obtained without correction, and the average root mean square error (RMSE) with the correction was 38.00% better than that without correction. In the subtraction study, the average CNR with correction was 2.04 (aluminum subtraction) and 1.38 (polymethyl methacrylate (PMMA) subtraction) times higher than that obtained without the correction. The analysis demonstrated the accuracy of scatter correction and the improvement of image quality using a primary modulator and showed the feasibility of

  10. Framework for Evaluating the Total Value Proposition of Clean Energy Technologies

    Energy Technology Data Exchange (ETDEWEB)

    Pater, J. E.

    2006-02-01

    Conventional valuation techniques fail to include many of the financial advantages of clean energy technologies. By omitting benefits associated with risk management, emissions reductions, policy incentives, resource use, corporate social responsibility, and societal economic benefits, investors and firms sacrifice opportunities for new revenue streams and avoided costs. In an effort to identify some of these externalities, this analysis develops a total value proposition for clean energy technologies. It incorporates a series of values under each of the above categories, describing the opportunities for recapturing investments throughout the value chain. The framework may be used to create comparable value propositions for clean energy technologies supporting investment decisions, project siting, and marketing strategies. It can also be useful in policy-making decisions.

  11. On the coherence between high-energy total cross-section data when compared with general principles

    International Nuclear Information System (INIS)

    Gauron, P.; Nicolescu, B.; Paris-6 Univ., 75

    1993-12-01

    An essential model is performed - an independent study of the internal coherence between high-energy total cross-section data by using classes of functions satisfying general principles. The study is practically independent of the ρ-parameter values. This general analysis, made without any fit, reveals certain inconsistencies in the existing set of high-energy data. Some of these inconsistencies are eliminated by giving up arbitrary assumptions sometimes made in 'fitology'. It is shown that the ln 2 s increase of total cross-sections at high energies is clearly favoured when compared with other possible behaviours. (authors). 16 refs., 3 figs

  12. Forecasting of the incorporated energy in the final demand of the brazilian economy in 2005

    International Nuclear Information System (INIS)

    Cunha, Marcelo Pereira da; Pereira, Jose Tomaz Vieira

    2008-01-01

    This work presents the application of a methodology for evaluation of the primary energy incorporated by the productive sectors of a economy at the final demand - using of a income-product mode. A methodology is applied in the evaluation of the energy incorporated to 25 sectors of the brazilian economy, by using the the data available in the national counts (IBGE - 2007), and the National Energy Balance for the year 2005 (EPE - 2007). For each sector, the results are presented in terms of the primary energy incorporated (in petroleum equivalent tons per R$ 1,000), of the participation of renewable energy, and the total primary energy distribution for the offered products by the 25 sectors to be consumption by the final demand. Among some interesting results in terms of final demand, it is highlighted the presence of 96.5% of renewable primary energy for the sector of alcohol, and 5.3% for the sector of petroleum refining products sector. In terms of the total energy distribution,the petroleum refining and coke sector were the most significant contribution to the incorporation of primary energy, presenting 16.1% of the total ahead of foods and beverages which presents 12.1%. Related to the final demand components, families consumption was responsible by the 57.7% of the total, the exports with 25.3%, the gross capital formation (investments and stock variations) with 11.3%, and the govern consumption wit 5.7%

  13. Distribution of energy carriers and resulting CO2 emission caused by the use of energy in Norwegian buildings

    International Nuclear Information System (INIS)

    Enlid, Elin; Tokle, Trude

    1999-03-01

    This report calculates the primary energy used in heating and management of buildings in Norway and distributes it according to user category and energy carrier. It also calculates the emission of carbon dioxide caused by this energy use. The total amount of energy used for heating and management of buildings in Norway in 1997 was 84 TWh. The corresponding emission of carbon dioxide was 10.5 mill tonnes, about 25% of the total domestic emission of carbon dioxide, including transport

  14. International energy annual, 1989

    International Nuclear Information System (INIS)

    1991-02-01

    This report is prepared annually and presents the latest information and trends on world energy production, consumption, reserves, trade, and prices for five primary energy sources: petroleum, natural gas, coal, hydroelectricity, and nuclear electricity. It also presents information on petroleum products. Since the early 1980's the world's total output of primary energy has increased steadily. The annual average growth rate of energy production during the decade was 1.9 percent. Throughout the 1980's, petroleum was the world's most heavily used type of energy. In 1989, three countries--the United States, the USSR, and China--were the leading producers and consumers of world energy. Together, these countries consumed and produced almost 50 percent of the world's total energy. Global production and consumption of crude oil and natural gas liquids increased during the 1980's, despite a decline in total production and demand in the early part of the decade. World production of dry natural gas continued to rise steadily in the 1980's. For the last several years, China has been the leading producer of coal, followed by the United States. In 1989, hydroelectricity supply declined slightly from the upward trend of the last 10 years. Nuclear power generation rose slightly from the 1988 level, compared with the marked growth in earlier years. Prices for major crude oils all increased between 1988 and 1989, but remained well below the price levels at the beginning of the decade. 26 figs., 36 tabs

  15. Total electron scattering cross sections for methanol and ethanol at intermediate energies

    International Nuclear Information System (INIS)

    Silva, D G M; Tejo, T; Lopes, M C A; Muse, J; Romero, D; Khakoo, M A

    2010-01-01

    Absolute total cross section (TCS) measurements of electron scattering from gaseous methanol and ethanol molecules are reported for impact energies from 60 to 500 eV, using the linear transmission method. The attenuation of intensity of a collimated electron beam through the target volume is used to determine the absolute TCS for a given impact energy, using the Beer-Lambert law to first approximation. Besides these experimental measurements, we have also determined TCS using the additivity rule.

  16. Targeting for energy efficiency and improved energy collaboration between different companies using total site analysis (TSA)

    International Nuclear Information System (INIS)

    Hackl, Roman; Andersson, Eva; Harvey, Simon

    2011-01-01

    Rising fuel prices, increasing costs associated with emissions of green house gases and the threat of global warming make efficient use of energy more and more important. Industrial clusters have the potential to significantly increase energy efficiency by energy collaboration. In this paper Sweden's largest chemical cluster is analysed using the total site analysis (TSA) method. TSA delivers targets for the amount of utility consumed and generated through excess energy recovery by the different processes. The method enables investigation of opportunities to deliver waste heat from one process to another using a common utility system. The cluster consists of 5 chemical companies producing a variety of products, including polyethylene (PE), polyvinyl chloride (PVC), amines, ethylene, oxygen/nitrogen and plasticisers. The companies already work together by exchanging material streams. In this study the potential for energy collaboration is analysed in order to reach an industrial symbiosis. The overall heating and cooling demands of the site are around 442 MW and 953 MW, respectively. 122 MW of heat is produced in boilers and delivered to the processes. TSA is used to stepwise design a site-wide utility system which improves energy efficiency. It is shown that heat recovery in the cluster can be increased by 129 MW, i.e. the current utility demand could be completely eliminated and further 7 MW excess steam can be made available. The proposed retrofitted utility system involves the introduction of a site-wide hot water circuit, increased recovery of low pressure steam and shifting of heating steam pressure to lower levels in a number heat exchangers when possible. Qualitative evaluation of the suggested measures shows that 60 MW of the savings potential could to be achieved with moderate changes to the process utility system corresponding to 50% of the heat produced from purchased fuel in the boilers of the cluster. Further analysis showed that after implementation

  17. Nuclear primary energy carriers. Pt. 2

    International Nuclear Information System (INIS)

    1978-04-01

    A very brief presentation of the elementary fusion reactions, the energies delivered by them and the most basic energy balances leading to Lawsontype diagrams are given. The reserves and cost of lithium and deuterium, gives estimates of the total available from DT fusion and comments on production technology, availability and handling of the fuels are outlined. A survey is given of the different concepts of magnetic confinement (stellarators, tokamaks, toroidal pinches, mirror machines, two-component plasmas), of confinement by walls, gas blankets and imploding liners and, finally, of the concepts of inertial confinement (laser fusion, beam fusion). The reactors designed or outlined on the basis of the tokamak, high-β, mirror, and laser fusion concepts are presented, which is followed by a discussion of the key problems of fusion power plants. The main reqirements on the superconducting magnet system for possible fusion reactors, particularly tokamak reactors, are discussed and compared with the present state of the superconducting magent technology. The present-day knowledge of the cost structure of fusion power plants and the sensitivity of this structure with respect to the physical and technical assumptions made is analysed. Finally the aspects of safety and environment are treated. The problems discussed include the hazard potentials of different designs (radiological, toxicological, and with respect to stored energies), release of radioactivity, possible kinds of malfunctioning, and the environmental impact of waste heat, radiation and radioactive waste. (orig.) [de

  18. The conditions for total reflection of low-energy atoms from crystal surfaces

    International Nuclear Information System (INIS)

    Hou, M.; Robinson, M.T.

    1978-01-01

    The critical angles for the total reflection of low-energy particles from Cu rows and (001) planes have been investigated, using the binary collision approximation computer simulation code MARLOWE Breakthrough angles were evaluated for H, N, Ne, Ar, Cu, Xe, and Au in the energy range from 0.1 to 7.5 keV. In both the axial and the planar cases, recoiling of the target atoms lowers the energy barrier which the target surface presents to the heavy projectiles. Consequently, the breakthrough angles are reduced for heavy projectiles below the values expected either from observations on light projectiles or from analytical channeling theory. (orig.) [de

  19. The causal link between energy and output growth: Evidence from Markov switching Granger causality

    International Nuclear Information System (INIS)

    Kandemir Kocaaslan, Ozge

    2013-01-01

    In this paper we empirically investigate the causal link between energy consumption and economic growth employing a Markov switching Granger causality analysis. We carry out our investigation using annual U.S. real GDP, total final energy consumption and total primary energy consumption data which cover the period between 1968 and 2010. We find that there are significant changes in the causal relation between energy consumption and economic growth over the sample period under investigation. Our results show that total final energy consumption and total primary energy consumption have significant predictive content for real economic activity in the U.S. economy. Furthermore, the causality running from energy consumption to output growth seems to be strongly apparent particularly during the periods of economic downturn and energy crisis. We also document that output growth has predictive power in explaining total energy consumption. Furthermore, the power of output growth in predicting total energy consumption is found to diminish after the mid of 1980s. - Highlights: • Total energy consumption has predictive content for real economic activity. • The causality from energy to output growth is apparent in the periods of recession. • The causality from energy to output growth is strong in the periods of energy crisis. • Output growth has predictive power in explaining total energy consumption. • The power of output growth in explaining energy diminishes after the mid of 1980s

  20. Is there an optimum level for renewable energy?

    International Nuclear Information System (INIS)

    Moriarty, Patrick; Honnery, Damon

    2011-01-01

    Because continued heavy use of fossil fuel will lead to both global climate change and resource depletion of easily accessible fuels, many researchers advocate a rapid transition to renewable energy (RE) sources. In this paper we examine whether RE can provide anywhere near the levels of primary energy forecast by various official organisations in a business-as-usual world. We find that the energy costs of energy will rise in a non-linear manner as total annual primary RE output increases. In addition, increasing levels of RE will lead to increasing levels of ecosystem maintenance energy costs per unit of primary energy output. The result is that there is an optimum level of primary energy output, in the sense that the sustainable level of energy available to the economy is maximised at that level. We further argue that this optimum occurs at levels well below the energy consumption forecasts for a few decades hence. - Highlights: → We need to shift to renewable energy for climate change and fuel depletion reasons. → We examine whether renewable energy can provide the primary energy levels forecast. → The energy costs of energy rise non-linearly with renewable energy output. → There is thus an optimum level of primary energy output. → This optimum occurs at levels well below future official energy use forecasts.

  1. Primary frequency regulation with Li-ion battery energy storage system: A case study for Denmark

    DEFF Research Database (Denmark)

    Swierczynski, Maciej Jozef; Stroe, Daniel Ioan; Stan, Ana-Irina

    2013-01-01

    Meeting ambitious goals of transition to distributed and environmentally-friendly renewable energy generation can be difficult to achieve without energy storage systems due to technical and economical challenges. Moreover, energy storage systems have a high potential of not only smoothing and imp...... electricity market. Moreover, in this paper a possible improvement of the Li-ion BESS energy management strategy is shown, which allows for obtaining the higher NPV....... lifetime, which introduces significant risk into the business model. This paper deals with the investigation of the lifetime of LiFeP04/C battery systems when they are used to provide primary frequency regulation service. A semi-empirical lifetime model for these battery cells was developed based...... on the results obtained from accelerated lifetime testing. The developed Li­-ion battery lifetime model is later a base for the analyses of the economic profitability of the investment in the Li-ion battery energy storage system (BESS), which delivers the primary frequency regulation service on the Danish...

  2. Optimization of stand-alone photovoltaic systems with hydrogen storage for total energy self-sufficiency

    Energy Technology Data Exchange (ETDEWEB)

    Lund, P D [Helsinki Univ. of Technology, Espoo (Finland). Dept. of Technical Physics

    1991-01-01

    A new method for optimization of stand-alone photovoltaic-hydrogen energy systems is presented. The methodology gives the optimum values for the solar array and hydrogen storage size for any given system configuration and geographical site. Sensitivity analyses have been performed to study the effect of subsystem efficiencies on the total system performance and sizing, and also to identify possibilities for further improvements. Optimum system configurations have also been derived. The results indicate that a solar-hydrogen energy system is a very promising potential alternative for low power applications requiring a total electricity self-sufficiency. (Author).

  3. Measurement of the total solar energy transmittance (g-value) for conventional glazings

    DEFF Research Database (Denmark)

    Duer, Karsten

    1998-01-01

    Three different glazings have been investigated in the Danish experimental setup METSET. (A device for calorimetric measurement of total solar energy transmittance - g-value).The purpose of the measurements is to increase the confidence in the calorimetric measurements. This is done by comparison...

  4. Hadronic multiplicity and total cross-section: a new scaling in wide energy range

    International Nuclear Information System (INIS)

    Kobylinsky, N.A.; Martynov, E.S.; Shelest, V.P.

    1983-01-01

    The ratio of mean multiplicity to total cross-section is shown to be the same for all the Regge models and to rise with energy as lns which is confirmed by experimental data. Hence, a power of multiplicity growth is unambiguously connected with that of total cross-section. As regards the observed growth, approximately ln 2 s, it tells about a dipole character of pomeron singularity

  5. On the interpretation of total current spectroscopy (TCS) spectra from MoS2 crystals

    International Nuclear Information System (INIS)

    Mohamed, M.H.; Moeller, P.J.

    1981-01-01

    Total Current Spectroscopy (TCS) spectra from MoS 2 (0001) face for three different angles of incidence of the primary beam with respect to the c-axis as well as TCS spectrum from an edge surface cut perpendicularly to the (001) face of a molybdenite crystal are given. Energy positions of the TCS structure are found to be independent of the variations in the angle of incidence of the primary beam and also of the change of crystal face. From this it is concluded that the fine structure in the TCS spectra from molybdenite crystal for the primary energies studied is due to electron-electron scattering and not to Bragg interference effects. (author)

  6. Primary energy use for heating in the Swedish building sector-Current trends and proposed target

    International Nuclear Information System (INIS)

    Johansson, P.; Nylander, A.; Johnsson, F.

    2007-01-01

    One goal of the Swedish energy policy is to reduce the amount of electricity used for heating in the building sector. This means to reduce the primary energy used for heating which in this paper is analyzed in the context of various heating technologies and CO 2 emissions. The analysis is applied to a region in Sweden (southern Sweden) for which detailed information on the energy infrastructure (the capital stock of the buildings and heating systems together with geographical variations in heat intensity) is available from a previous work [Johansson, P., Nylander, A., Johnsson, F., 2005. Electricity dependency and CO 2 emissions from heating in the Swedish building sector-current trends in conflict with governmental policy? Energy policy] and which is large enough to be assumed representative for Sweden as a whole. The detailed mapping of the energy infrastructure allows a good estimate on the rate at which the energy system can be expected to be replaced with respect to economical lifetime of the capital stock (the year 2025 in this case). Two scenarios are investigated; a target scenario for which energy savings are employed (e.g. improving climate shell in buildings) and oil and most of the electricity used for heating purposes are phased out and a second for which the current trend in the heating market continues. In the target scenario it is shown that although only applying commercially competitive heating technologies, it is possible to achieve a 47% reduction in primary energy use for heating with a 34% decrease in heat demand together with significant reduction in CO 2 emissions. However, the scenario which continues the current trends on the heating market instead yields an increase (of about 10%) in primary energy use (reduction in conversion efficiency) of the heating system of the region over the period studied, in spite of a slight decrease in heat demand (9%, mainly due to energy efficiency measures) as well as in CO 2 emissions. In light of the

  7. Total cross section for hadron production by e+e- annihilation at PETRA energies

    International Nuclear Information System (INIS)

    Bartel, W.; Canzler, T.; Cords, D.; Dittmann, P.; Eichler, R.; Felst, R.; Godermann, E.; Haidt, D.; Kawabata, S.; Krehbiel, H.

    1979-10-01

    The cross section for the process e + e - → multihadrons has been measured at the highest PETRA energies. We measure R (the total cross-section in units of the point-like e + e - → μ + μ - cross-section) to be 2.9 +- 0.7, 4.0 +- 0.5, 4.6 +- 0.4 and 4.2 +- 0.6 at √s of 22, 27.7, 30 and 31.6 GeV respectively. The observed average multiplicity, together with existing low energy data, indicate a rapid increase in multiplicity with increasing energy. (orig.)

  8. Total cross sections for electron scattering by CO2 molecules in the energy range 400 endash 5000 eV

    International Nuclear Information System (INIS)

    Garcia, G.; Manero, F.

    1996-01-01

    Total cross sections for electron scattering by CO 2 molecules in the energy range 400 endash 5000 eV have been measured with experimental errors of ∼3%. The present results have been compared with available experimental and theoretical data. The dependence of the total cross sections on electron energy shows an asymptotic behavior with increasing energies, in agreement with the Born-Bethe approximation. In addition, an analytical formula is provided to extrapolate total cross sections to higher energies. copyright 1996 The American Physical Society

  9. National energy balance - 1995 of Brazil. Based on 1994

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-12-31

    Consolidated data of production, consumption and external dependence of energy are presented, as also the sectorial composition of the consumption of the different groups of energy sources. For each primary and secondary source the production, import, export, variations in inventories, losses, adjustments and total consumption are analyzed. Balances of transformation centers, characterizing the energy the energy processed, the energy produced and the respective losses in transformation are shown. Finally energy resources and reserves of primary sources are described with respective methodologies for estimating them. 60 figs., 107 tabs.

  10. National energy balance - 1995 of Brazil. Based on 1994

    International Nuclear Information System (INIS)

    1995-01-01

    Consolidated data of production, consumption and external dependence of energy are presented, as also the sectorial composition of the consumption of the different groups of energy sources. For each primary and secondary source the production, import, export, variations in inventories, losses, adjustments and total consumption are analyzed. Balances of transformation centers, characterizing the energy the energy processed, the energy produced and the respective losses in transformation are shown. Finally energy resources and reserves of primary sources are described with respective methodologies for estimating them. 60 figs., 107 tabs

  11. National energy balance - 1995 of Brazil. Based on 1994

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-12-31

    Consolidated data of production, consumption and external dependence of energy are presented, as also the sectorial composition of the consumption of the different groups of energy sources. For each primary and secondary source the production, import, export, variations in inventories, losses, adjustments and total consumption are analyzed. Balances of transformation centers, characterizing the energy the energy processed, the energy produced and the respective losses in transformation are shown. Finally energy resources and reserves of primary sources are described with respective methodologies for estimating them. 60 figs., 107 tabs.

  12. Acetabular cup position and risk of dislocation in primary total hip arthroplasty

    DEFF Research Database (Denmark)

    Seagrave, Kurt G; Troelsen, Anders; Malchau, Henrik

    2017-01-01

    Background and purpose - Hip dislocation is one of the most common complications following total hip arthroplasty (THA). Several factors that affect dislocation have been identified, including acetabular cup positioning. Optimal values for cup inclination and anteversion are debatable. We performed...... a systematic review to describe the different methods for measuring cup placement, target zones for cup positioning, and the association between cup positioning and dislocation following primary THA. Methods - A systematic search of literature in the PubMed database was performed (January and February 2016......) to identify articles that compared acetabular cup positioning and the risk of dislocation. Surgical approach and methods for measurement of cup angles were also considered. Results - 28 articles were determined to be relevant to our research question. Some articles demonstrated that cup positioning influenced...

  13. Near-term Forecasting of Solar Total and Direct Irradiance for Solar Energy Applications

    Science.gov (United States)

    Long, C. N.; Riihimaki, L. D.; Berg, L. K.

    2012-12-01

    Integration of solar renewable energy into the power grid, like wind energy, is hindered by the variable nature of the solar resource. One challenge of the integration problem for shorter time periods is the phenomenon of "ramping events" where the electrical output of the solar power system increases or decreases significantly and rapidly over periods of minutes or less. Advance warning, of even just a few minutes, allows power system operators to compensate for the ramping. However, the ability for short-term prediction on such local "point" scales is beyond the abilities of typical model-based weather forecasting. Use of surface-based solar radiation measurements has been recognized as a likely solution for providing input for near-term (5 to 30 minute) forecasts of solar energy availability and variability. However, it must be noted that while fixed-orientation photovoltaic panel systems use the total (global) downwelling solar radiation, tracking photovoltaic and solar concentrator systems use only the direct normal component of the solar radiation. Thus even accurate near-term forecasts of total solar radiation will under many circumstances include inherent inaccuracies with respect to tracking systems due to lack of information of the direct component of the solar radiation. We will present examples and statistical analyses of solar radiation partitioning showing the differences in the behavior of the total/direct radiation with respect to the near-term forecast issue. We will present an overview of the possibility of using a network of unique new commercially available total/diffuse radiometers in conjunction with a near-real-time adaptation of the Shortwave Radiative Flux Analysis methodology (Long and Ackerman, 2000; Long et al., 2006). The results are used, in conjunction with persistence and tendency forecast techniques, to provide more accurate near-term forecasts of cloudiness, and both total and direct normal solar irradiance availability and

  14. The total cross section as a function of energy for elastic scattering of noble gas atoms

    International Nuclear Information System (INIS)

    Linse, C.A.

    1978-01-01

    Precise relative measurements of the total cross-sections as a function of velocity is presented for the systems Ar-Ar, Ar-Kr, Kr-Ar, Ar-Xe, Ne-Ar, Ne-Kr, and Ne-Xe, the primary beam particle being mentioned first. A discription of the apparatus is given. Then the method for extracting total cross-sections from the measured beam attenuation is analyzed. A comparison is made with total cross-sections calculated from various potentials that have been proposed in the literature

  15. Energy spectra of primary knock-on atoms under neutron irradiation

    International Nuclear Information System (INIS)

    Gilbert, M.R.; Marian, J.; Sublet, J.-Ch.

    2015-01-01

    Materials subjected to neutron irradiation will suffer from a build-up of damage caused by the displacement cascades initiated by nuclear reactions. Previously, the main “measure” of this damage accumulation has been through the displacements per atom (dpa) index, which has known limitations. This paper describes a rigorous methodology to calculate the primary atomic recoil events (often called the primary knock-on atoms or PKAs) that lead to cascade damage events as a function of energy and recoiling species. A new processing code SPECTRA-PKA combines a neutron irradiation spectrum with nuclear recoil data obtained from the latest nuclear data libraries to produce PKA spectra for any material composition. Via examples of fusion relevant materials, it is shown that these PKA spectra can be complex, involving many different recoiling species, potentially differing in both proton and neutron number from the original target nuclei, including high energy recoils of light emitted particles such as α-particles and protons. The variations in PKA spectra as a function of time, neutron field, and material are explored. The application of PKA spectra to the quantification of radiation damage is exemplified using two approaches: the binary collision approximation and stochastic cluster dynamics, and the results from these different models are discussed and compared. - Highlights: • Recoil cross-section matrices under neutron irradiation are generated. • Primary knock-on atoms (PKA) spectra are calculated for fusion relevant materials. • Variation in PKA spectra due to changes in geometry are considered. • Inventory simulations to consider time-evolution in PKA spectra. • Damage quantification using damage functions from different approximations.

  16. Windows with improved energy performances

    DEFF Research Database (Denmark)

    Laustsen, Jacob Birck; Svendsen, Svend

    2003-01-01

    Heat loss through windows represents a considerable part of the total heat loss from houses. However, apart from providing daylight access and view, windows offer a unique potential for solar gain to be exploited during the heating season. Until now valuation of the energy performance of windows...... has primary focused on the heat loss coefficient, U-value. However, as the U-value, especially for the glazing part, has improved considerably during the last years, the total solar energy transmittance, g-value, has become equally important to the total energy performance of windows. Improved energy...... resulted in a window with a positive net energy gain (in short the Net Gain Window), which means that it contributes to the space heating of the building. All improvements are based on existing technology and manufacturing methods. The results from this work show that the energy performances of windows can...

  17. Energy intensities of food products. Energie-intensiteiten van voedingsmiddelen

    Energy Technology Data Exchange (ETDEWEB)

    Kok, R.; Biesiot, W.; Wilting, H.C.

    1993-08-01

    The energy intensity of a product is the amount of primary energy used per Dutch guilder spent on consumer goods. The energy intensity can differ for each spending and varies from household to household. The aim of this study is to calculate the energy intensities and to provide an overview of the total package of consumer goods, including sociological categories and lifestyles, and the related use of primary energy to produce these goods. Use is made of the Energy Analysis Program (EAP) to calculate the energy intensities. EAP is based on the hybrid method: both the process analysis and the input-output analysis are applied in the model. The data input of the model consists of data from the Budget Survey 1990 of the Dutch Central Bureau of Statistics, which holds data of consumptions from 2767 households. In the chapters 4 to 10 energy intensities are given of the categories bread, pastry and groceries (chapter four), potatoes, vegetables and fruits (chapter five), sugary products and beverages (chapter six), oils and fats (chapter seven), meat, meat products and fish (chapter eight), dairy products (chapter nine), and other food products (chapter ten). The highest energy intensity is found for oils and fats (13.5 MJ per Dutch guilder). The energy intensities for the other products vary from 4.0 to 6.6 MJ/gld. It appears that most of the energy intensive products are products which do not use a large part of the primary energy, mainly because the consumption of these products is low. On the other hand many of the products that consume much of the primary energy (i.e. are consumed much themselves) are relatively energy extensive. The products that show a high consumption rate have relatively low energy intensities. Some of the options to shift towards a more energy extensive food package are the use of fresh products and outside grown products instead of treated products or greenhouse products and a more balanced diet. 5 figs., 18 tabs., 2 appendices, 52 refs.

  18. Operation optimization of a distributed energy system considering energy costs and exergy efficiency

    International Nuclear Information System (INIS)

    Di Somma, M.; Yan, B.; Bianco, N.; Graditi, G.; Luh, P.B.; Mongibello, L.; Naso, V.

    2015-01-01

    Highlights: • Operation optimization model of a Distributed Energy System (DES). • Multi-objective strategy to optimize energy cost and exergy efficiency. • Exergy analysis in building energy supply systems. - Abstract: With the growing demand of energy on a worldwide scale, improving the efficiency of energy resource use has become one of the key challenges. Application of exergy principles in the context of building energy supply systems can achieve rational use of energy resources by taking into account the different quality levels of energy resources as well as those of building demands. This paper is on the operation optimization of a Distributed Energy System (DES). The model involves multiple energy devices that convert a set of primary energy carriers with different energy quality levels to meet given time-varying user demands at different energy quality levels. By promoting the usage of low-temperature energy sources to satisfy low-quality thermal energy demands, the waste of high-quality energy resources can be reduced, thereby improving the overall exergy efficiency. To consider the economic factor as well, a multi-objective linear programming problem is formulated. The Pareto frontier, including the best possible trade-offs between the economic and exergetic objectives, is obtained by minimizing a weighted sum of the total energy cost and total primary exergy input using branch-and-cut. The operation strategies of the DES under different weights for the two objectives are discussed. The operators of DESs can choose the operation strategy from the Pareto frontier based on costs, essential in the short run, and sustainability, crucial in the long run. The contribution of each energy device in reducing energy costs and the total exergy input is also analyzed. In addition, results show that the energy cost can be much reduced and the overall exergy efficiency can be significantly improved by the optimized operation of the DES as compared with the

  19. Evaluation of total energy-rate feedback for glidescope tracking in wind shear

    Science.gov (United States)

    Belcastro, C. M.; Ostroff, A. J.

    1986-01-01

    Low-altitude wind shear is recognized as an infrequent but significant hazard to all aircraft during take-off and landing. A total energy-rate sensor, which is potentially applicable to this problem, has been developed for measuring specific total energy-rate of an airplane with respect to the air mass. This paper presents control system designs, with and without energy-rate feedback, for the approach to landing of a transport airplane through severe wind shear and gusts to evaluate application of this sensor. A system model is developed which incorporates wind shear dynamics equations with the airplance equations of motion, thus allowing the control systems to be analyzed under various wind shears. The control systems are designed using optimal output feedback and are analyzed using frequency domain control theory techniques. Control system performance is evaluated using a complete nonlinear simulation of the airplane and a severe wind shear and gust data package. The analysis and simulation results indicate very similar stability and performance characteristics for the two designs. An implementation technique for distributing the velocity gains between airspeed and ground speed in the simulation is also presented, and this technique is shown to improve the performance characteristics of both designs.

  20. Local electron mean energy profile of positive primary streamer discharge with pin-plate electrodes in oxygen—nitrogen mixtures

    International Nuclear Information System (INIS)

    Sima Wen-Xia; Peng Qing-Jun; Yang Qing; Yuan Tao; Shi Jian

    2013-01-01

    Local electron mean energy (LEME) has a direct effect on the rates of collisional ionization of molecules and atoms by electrons. Electron-impact ionization plays an important role and is the main process for the production of charged particles in a primary streamer discharge. Detailed research on the LEME profile in a primary streamer discharge is extremely important for a comprehensive understanding of the local physical mechanism of a streamer. In this study, the LEME profile of the primary streamer discharge in oxygen-nitrogen mixtures with a pin-plate gap of 0.5 cm under an impulse voltage is investigated using a fluid model. The fluid model includes the electron mean energy density equation, as well as continuity equations for electrons and ions and Poisson's electric field equation. The study finds that, except in the initial stage of the primary streamer, the LEME in the primary streamer tip tends to increase as the oxygen-nitrogen mole ratio increases and the pressure decreases. When the primary streamer bridges the gap, the LEME in the primary streamer channel is smaller than the first ionization energies of oxygen and nitrogen. The LEME in the primary streamer channel then decreases as the oxygen-nitrogen mole ratio increases and the pressure increases. The LEME in the primary streamer tip is primarily dependent on the reduced electric field with mole ratios of oxygen-nitrogen given in the oxygen-nitrogen mixtures. (physics of gases, plasmas, and electric discharges)

  1. Sorting through the many total-energy-cycle pathways possible with early plug-in hybrids

    International Nuclear Information System (INIS)

    Gaines, L.; Burnham, A.; Rousseau, A.; Santini, D.

    2008-01-01

    Using the 'total energy cycle' methodology, we compare U.S. near term (to ∼2015) alternative pathways for converting energy to light-duty vehicle kilometers of travel (VKT) in plug-in hybrids (PHEVs), hybrids (HEVs), and conventional vehicles (CVs). For PHEVs, we present total energy-per-unit-of-VKT information two ways (1) energy from the grid during charge depletion (CD); (2) energy from stored on-board fossil fuel when charge sustaining (CS). We examine 'incremental sources of supply of liquid fuel such as (a) oil sands from Canada, (b) Fischer-Tropsch diesel via natural gas imported by LNG tanker, and (c) ethanol from cellulosic biomass. We compare such fuel pathways to various possible power converters producing electricity, including (i) new coal boilers, (ii) new integrated, gasified coal combined cycle (IGCC), (iii) existing natural gas fueled combined cycle (NGCC), (iv) existing natural gas combustion turbines, (v) wood-to-electricity, and (vi) wind/solar. We simulate a fuel cell HEV and also consider the possibility of a plug-in hybrid fuel cell vehicle (FCV). For the simulated FCV our results address the merits of converting some fuels to hydrogen to power the fuel cell vs. conversion of those same fuels to electricity to charge the PHEV battery. The investigation is confined to a U.S. compact sized car (i.e. a world passenger car). Where most other studies have focused on emissions (greenhouse gases and conventional air pollutants), this study focuses on identification of the pathway providing the most vehicle kilometers from each of five feedstocks examined. The GREET 1.7 fuel cycle model and the new GREET 2.7 vehicle cycle model were used as the foundation for this study. Total energy, energy by fuel type, total greenhouse gases (GHGs), volatile organic compounds (VOC), carbon monoxide (CO), nitrogen oxides (NO x ), fine particulate (PM2.5) and sulfur oxides (SO x ) values are presented. We also isolate the PHEV emissions contribution from varying k

  2. Field Experience from Li-Ion BESS Delivering Primary Frequency Regulation in the Danish Energy Market

    DEFF Research Database (Denmark)

    Swierczynski, Maciej Jozef; Stroe, Daniel Ioan; Lærke, Rasmus

    2014-01-01

    In this paper it is presented the practical experience from operating a 1.6 MW/ 0.4 MWh lithium ion battery energy storage system, which is providing primary frequency regulation service on the Danish energy market. Aspects of the battery system requirements and the used control strategy...

  3. Energies and raw materials. The energy situation

    International Nuclear Information System (INIS)

    1997-09-01

    Statistics are given on the energy and raw materials (coal, oil, etc.) production and consumption levels in France in September 1997: primary energy total consumption has increased (mobile year) of 1.1%, at the same rate since 3 years. Interior demand has varied depending on the energy: strong decrease for coal (- 5.9%), slight increase for petroleum products (+ 0.8%), strong increase for gas (+ 3.2%) and moderate increase for electricity (+ 1.7%). An increase in the dollar exchange rate and a high level of oil and gas imports have induced a record energy cost level with + 30% on one year, reaching 89.2 billions Francs, to be compared to 68.5 in September 1996

  4. What are the important manoeuvres for beginners to minimize surgical time in primary total knee arthroplasty?

    Science.gov (United States)

    Harato, Kengo; Maeno, Shinichi; Tanikawa, Hidenori; Kaneda, Kazuya; Morishige, Yutaro; Nomoto, So; Niki, Yasuo

    2016-08-01

    It was hypothesized that surgical time of beginners would be much longer than that of experts. Our purpose was to investigate and clarify the important manoeuvres for beginners to minimize surgical time in primary total knee arthroplasty (TKA) as a multicentre study. A total of 300 knees in 248 patients (averaged 74.6 years) were enrolled. All TKAs were done using the same instruments and the same measured resection technique at 14 facilities by 25 orthopaedic surgeons. Surgeons were divided into three surgeon groups (four experts, nine medium-volume surgeons and 12 beginners). The surgical technique was divided into five phases. Detailed surgical time and ratio of the time in each phase to overall surgical time were recorded and compared among the groups in each phase. A total of 62, 119, and 119 TKAs were done by beginners, medium-volume surgeons, and experts, respectively. Significant differences in surgical time among the groups were seen in each phase. Concerning the ratio of the time, experts and medium-volume surgeons seemed cautious in fixation of the permanent component compared to other phases. Interestingly, even in ratio, beginners and medium-volume surgeons took more time in exposure of soft tissue compared to experts. (0.14 in beginners, 0.13 in medium-volume surgeons, 0.11 in experts, P time in exposure and closure of soft tissue compared to experts. Improvement in basic technique is essential to minimize surgical time among beginners. First of all, surgical instructors should teach basic techniques in primary TKA for beginners. Therapeutic studies, Level IV.

  5. Prediction equation for estimating total daily energy requirements of special operations personnel.

    Science.gov (United States)

    Barringer, N D; Pasiakos, S M; McClung, H L; Crombie, A P; Margolis, L M

    2018-01-01

    Special Operations Forces (SOF) engage in a variety of military tasks with many producing high energy expenditures, leading to undesired energy deficits and loss of body mass. Therefore, the ability to accurately estimate daily energy requirements would be useful for accurate logistical planning. Generate a predictive equation estimating energy requirements of SOF. Retrospective analysis of data collected from SOF personnel engaged in 12 different SOF training scenarios. Energy expenditure and total body water were determined using the doubly-labeled water technique. Physical activity level was determined as daily energy expenditure divided by resting metabolic rate. Physical activity level was broken into quartiles (0 = mission prep, 1 = common warrior tasks, 2 = battle drills, 3 = specialized intense activity) to generate a physical activity factor (PAF). Regression analysis was used to construct two predictive equations (Model A; body mass and PAF, Model B; fat-free mass and PAF) estimating daily energy expenditures. Average measured energy expenditure during SOF training was 4468 (range: 3700 to 6300) Kcal·d- 1 . Regression analysis revealed that physical activity level ( r  = 0.91; P  plan appropriate feeding regimens to meet SOF nutritional requirements across their mission profile.

  6. Local sharing of cogeneration energy through individually prioritized controls for increased on-site energy utilization

    International Nuclear Information System (INIS)

    Hirvonen, Janne; Kayo, Genku; Hasan, Ala; Sirén, Kai

    2014-01-01

    Highlights: • Sharing of surplus heat and electricity produced by CHP plants in different types of buildings. • Individually prioritized control of CHP plants with direct local sharing and minimal storage capacity. • Energy sharing reduced primary energy consumption by 1–9% with biogas. • Excess energy minimized by thermal tracking. - Abstract: All over the world, including Japan, there are targets to decrease building energy consumption and increase renewable energy utilization. Combined heat and power (CHP) plants increase energy efficiency and are becoming popular in Japan. CHP plants produce both heat and power simultaneously, but there is not always a need for both. A cluster of several different buildings can increase total efficiency and reduce primary energy (PE) consumption by sharing excess heat and electricity between neighboring buildings. If the generated energy comes from renewable sources, energy sharing makes it easier to reach the net zero energy balance. By adjusting CHP sizes and operation patterns, the wasted heat and primary energy consumption can be minimized. Energy sharing has been explored in situations with identical buildings and centrally administered energy systems before, but not with different building types with separate systems. In this study, a cluster of Japanese office and residential buildings were combined to allow heat and electricity sharing based on cogeneration, using individually prioritized control (IPC) systems. TRNSYS simulation was used to match energy generation with pregenerated demand profiles. Absorption cooling was utilized to increase the benefits of local heat generation. Different CHP operation modes and plant sizes were tested. The benefit of surplus energy sharing depends on the CHP capacities and the fuel type. When using biogas, larger CHP plants provided lower total primary energy consumption, in the most extreme case lowering it by 71%, compared to the conventional case. Using natural gas

  7. Low-dose dual-energy cone-beam CT using a total-variation minimization algorithm

    International Nuclear Information System (INIS)

    Min, Jong Hwan

    2011-02-01

    Dual-energy cone-beam CT is an important imaging modality in diagnostic applications, and may also find its use in other application such as therapeutic image guidance. Despite of its clinical values, relatively high radiation dose of dual-energy scan may pose a challenge to its wide use. In this work, we investigated a low-dose, pre-reconstruction type of dual-energy cone-beam CT (CBCT) using a total-variation minimization algorithm for image reconstruction. An empirical dual-energy calibration method was used to prepare material-specific projection data. Raw data at high and low tube voltages are converted into a set of basis functions which can be linearly combined to produce material-specific data using the coefficients obtained through the calibration process. From much fewer views than are conventionally used, material specific images are reconstructed by use of the total-variation minimization algorithm. An experimental study was performed to demonstrate the feasibility of the proposed method using a micro-CT system. We have reconstructed images of the phantoms from only 90 projections acquired at tube voltages of 40 kVp and 90 kVp each. Aluminum-only and acryl-only images were successfully decomposed. We evaluated the quality of the reconstructed images by use of contrast-to-noise ratio and detectability. A low-dose dual-energy CBCT can be realized via the proposed method by greatly reducing the number of projections

  8. The Geopolitics of Indian Energy

    Energy Technology Data Exchange (ETDEWEB)

    Ebinger, Charles

    2007-07-01

    In India today, debate about energy security and the implications for the nation's foreign policy is growing. To deal with this issue, India has adopted a multifaceted policy with six critical components: (1) diversifying the source and type of energy imports, (2) increasing domestic exploration for fossil fuels and development of nuclear power, (3) pursuing energy efficiency, (4) negotiating equity deals overseas, (5) building natural gas and electricity networks with its neighbors on a bilateral and sometimes multilateral basis, and (6) building strategic stocks of petroleum. This concern with energy security arises from the fact that India is currently the fifth largest consumer of energy in the world and is expected to see its primary energy demand double by 2030. In 2004 the nation's primary commercial energy demand was 375.8 million tons of oil equivalent (mtoe) (coal, oil, gas, and electricity) and is expected to more than double to 812 mtoe by 2030. As the 2006 ''Brookings Foreign Policy Studies Energy Security Report: India'' reminds us, these figures do not include the traditional forms of biomass and other energy consumed by nearly two thirds of all Indian households. Nor, based on the author's own research, do they include the off-grid diesel power used by a large number of Indian businesses, commercial households, and residential consumers, which the author will argue later may equal up to one half again the amount of electricity consumed in the country. It should be noted that, even though the percentage of traditional forms of energy in total primary energy usage is expected to decline from 34% to 21% by 2030, total nontraditional energy usage is expected to rise from 184 mtoe to 215 mtoe. The paper discusses various aspects related to the six critical components in greater detail.

  9. Energies and raw materials. The energy situation; Energies et matieres premieres. Conjoncture energetique

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-10-01

    Statistics are given on the energy and raw materials (coal, oil, etc.) production and consumption levels in France in October 1997: primary energy total consumption has increased (mobile year) of 0.8%, at the same rate since 3 years. Interior demand has varied depending on the energy: strong decrease for coal (- 8.1%), slight increase for petroleum products (+ 1.3%), slowing down increase for gas (+ 2.1%) and moderate increase for electricity (+ 1.4%). An increase in the dollar exchange rate and a high level of oil and gas imports have induced a high energy cost level with + 22% on one year, reaching 87.8 billions Francs, to be compared to 72.0 in October 1996

  10. Energies and raw materials. The energy situation; Energies et matieres premieres. Conjoncture energetique

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-09-01

    Statistics are given on the energy and raw materials (coal, oil, etc.) production and consumption levels in France in September 1997: primary energy total consumption has increased (mobile year) of 1.1%, at the same rate since 3 years. Interior demand has varied depending on the energy: strong decrease for coal (- 5.9%), slight increase for petroleum products (+ 0.8%), strong increase for gas (+ 3.2%) and moderate increase for electricity (+ 1.7%). An increase in the dollar exchange rate and a high level of oil and gas imports have induced a record energy cost level with + 30% on one year, reaching 89.2 billions Francs, to be compared to 68.5 in September 1996

  11. Energy use and energy intensity of the U.S. chemical industry

    Energy Technology Data Exchange (ETDEWEB)

    Worrell, E.; Phylipsen, D.; Einstein, D.; Martin, N.

    2000-04-01

    The U.S. chemical industry is the largest in the world, and responsible for about 11% of the U.S. industrial production measured as value added. It consumes approximately 20% of total industrial energy consumption in the U.S. (1994), and contributes in similar proportions to U.S. greenhouse gas emissions. Surprisingly, there is not much information on energy use and energy intensity in the chemical industry available in the public domain. This report provides detailed information on energy use and energy intensity for the major groups of energy-intensive chemical products. Ethylene production is the major product in terms of production volume of the petrochemical industry. The petrochemical industry (SIC 2869) produces a wide variety of products. However, most energy is used for a small number of intermediate compounds, of which ethylene is the most important one. Based on a detailed assessment we estimate fuel use for ethylene manufacture at 520 PJ (LHV), excluding feedstock use. Energy intensity is estimated at 26 GJ/tonne ethylene (LHV), excluding feedstocks.The nitrogenous fertilizer production is a very energy intensive industry, producing a variety of fertilizers and other nitrogen-compounds. Ammonia is the most important intermediate chemical compound, used as basis for almost all products. Fuel use is estimated at 268 PJ (excluding feedstocks) while 368 PJ natural gas is used as feedstock. Electricity consumption is estimated at 14 PJ. We estimate the energy intensity of ammonia manufacture at 39.3 GJ/tonne (including feedstocks, HHV) and 140 kWh/tonne, resulting in a specific primary energy consumption of 40.9 GJ/tonne (HHV), equivalent to 37.1 GJ/tonne (LHV). Excluding natural gas use for feedstocks the primary energy consumption is estimated at 16.7 GJ/tonne (LHV). The third most important product from an energy perspective is the production of chlorine and caustic soda. Chlorine is produced through electrolysis of a salt-solution. Chlorine production is

  12. Investigation on the correlation between energy deposition and clustered DNA damage induced by low-energy electrons.

    Science.gov (United States)

    Liu, Wei; Tan, Zhenyu; Zhang, Liming; Champion, Christophe

    2018-05-01

    This study presents the correlation between energy deposition and clustered DNA damage, based on a Monte Carlo simulation of the spectrum of direct DNA damage induced by low-energy electrons including the dissociative electron attachment. Clustered DNA damage is classified as simple and complex in terms of the combination of single-strand breaks (SSBs) or double-strand breaks (DSBs) and adjacent base damage (BD). The results show that the energy depositions associated with about 90% of total clustered DNA damage are below 150 eV. The simple clustered DNA damage, which is constituted of the combination of SSBs and adjacent BD, is dominant, accounting for 90% of all clustered DNA damage, and the spectra of the energy depositions correlating with them are similar for different primary energies. One type of simple clustered DNA damage is the combination of a SSB and 1-5 BD, which is denoted as SSB + BD. The average contribution of SSB + BD to total simple clustered DNA damage reaches up to about 84% for the considered primary energies. In all forms of SSB + BD, the SSB + BD including only one base damage is dominant (above 80%). In addition, for the considered primary energies, there is no obvious difference between the average energy depositions for a fixed complexity of SSB + BD determined by the number of base damage, but average energy depositions increase with the complexity of SSB + BD. In the complex clustered DNA damage constituted by the combination of DSBs and BD around them, a relatively simple type is a DSB combining adjacent BD, marked as DSB + BD, and it is of substantial contribution (on average up to about 82%). The spectrum of DSB + BD is given mainly by the DSB in combination with different numbers of base damage, from 1 to 5. For the considered primary energies, the DSB combined with only one base damage contributes about 83% of total DSB + BD, and the average energy deposition is about 106 eV. However, the

  13. Priority listing of industrial processes by total energy consumption and potential for savings. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Streb, A.J.

    1977-01-01

    A survey of eight of the most energy-intensive segments of the U.S. industry is made to quantify the energy consumed in the principal process units, to identify areas in which significant improvement appear possible, and to rank the process units in terms of total energy consumption and the potential for improvement. Data on the steel, paper, aluminum, textile, cement, and glass industries, petroleum refineries, and olefins and derivative products industries were compiled to help plan the development of new energy sources and to provide targets for energy conservation activities. (MCW)

  14. The most important structures utilizing primary and secondary hydroenergetic potential for electric energy production

    Energy Technology Data Exchange (ETDEWEB)

    Zacharovsky, M [Slovenske elektrarne, a.s., Vodne elektrarne Trencin (Slovakia)

    1997-12-01

    In this paper the construction, technological parameters and operation of Gabcikovo (primary hydro energy power) and Cierny Vah (secondary hydro energy power) are described. Construction of the hydroelectric power plant (HPP) Gabcikovo started in 1978 as a part of a system of hydro power projects Gabcikovo-Nagymaros. Basic technical data are: installed capacity 8 x 90 MW, production in an average aqueous year 2.650 GWh, number of hydroelectric generating sets (HGS) 8, turbine flow 8 x 413-636 m{sup 3}/s, head 12.9-24 m.The Gabcikovo plant produced 9.163 GWh of electricity from the beginning of its operation till the end of 1966. The construction of the pumped storage plant (PSP) Cierny Vah started in 1976 and it was put into operation at the end of 1980. The main goal of the PSP Cierny Vah is to meet the control functions of an electrification system of the Slovak Republic, a substitute function in the cases of unexpected power outages and a planned electricity production from re-pumping. Technological parts are: six re-pumping vertical HGS in a three machine arrangement - a motor-generator, a turbine, a pump - are located in three double-blocks. Basic technical data: installed capacity 6 x 122.4 MW + 0.768 MW, yearly production 1,281 GWh, number of HGS 6, number of domestic hydroelectric generating sets 1, turbine flow 3 x 30 m{sup /}s, pump flow 6 x 22 m{sup 3}/s, upper reservoir volume 3.7 mil. m{sup 3}, max. head 434 m, peak time 5.71 hour, pumping time 7.78 hour, re-pumping cycle efficiency 74.36%. From putting the PSP into operation till the end of 1996, the HGS in operation 145,269 hours in total, including 53,332 hours in a turbine mode of operation, 70,293 hours in a pumping mode operation and 21,644 hours in a compensation mode operation. Whereas they supplied 5,346 GWh in the mains and the consumed 6,933 GWh of electricity for pumping. Hydroenergetic potential is a primary source of energy which is recyclable, i.e. unexhaustible and also ecologically the

  15. Dielectric compound parabolic concentrating solar collector with frustrated total internal reflection absorber

    Science.gov (United States)

    Hull, J. R.

    Since its introduction, the concept of nonimaging solar concentrators, as exemplified by the compound parabolic concentrator (CPC) design, has greatly enhanced the ability to collect solar energy efficiently in thermal and photovoltaic devices. When used as a primary concentrator, a CPC can provide significant concentration without the complication of a tracking mechanism and its associated maintenance problems. When used as a secondary, a CPC provides higher total concentration, or for a fixed concentration, tolerates greater tracking error in the primary.

  16. A forecast of energy requirements in South Africa

    International Nuclear Information System (INIS)

    Kotze, D.J.

    1975-01-01

    The aim of this paper is to evaluate the adequacy of South Africa's energy resources relative to projected demands. The forecasting procedure embraces the construction of suitable energy balances and the development of econometric demand models. An energy balance is employed which integrates supply and demand data on all forms of energy for a particular year. The demand side of the balance is divided into both final demand and demand by the conversion sector. Useful energy consumption in each sector is estimated by applying utilisation efficiency co-efficients to the physics energy content of each energy form. Total final demand is determined by developing sub-models for each sector of final demand including households, industry, mining and transport. In these sub-models, economic series representing the type of activity in the particular sub-sector, are used as explanatory variables. Further relationships, quantifying the contributions of each form of energy to the sectorial totals, are constructed. Having established the future value of final useful energy demand, total future production and final consumption is obtained. The forecast of primary energy requirements is therefore made via a reversed calculation from the final energy demand through all conversion processes to the primary energy stage. Once the future distribution of energy by source, form and end use sector is known it is possible to plan the optimum allocation of energy resources in the country. It is also possible to evaluate the life of indigenous energy resources, their adequacy, and import requirements

  17. Regional and global exergy and energy efficiencies

    Energy Technology Data Exchange (ETDEWEB)

    Nakicenovic, N; Kurz, R [International Inst. for Applied Systems Analysis, Laxenburg (Austria). Environmentally Compatible Energy Strategies (Ecuador) Project; Gilli, P V [Graz Univ. of Technology (Austria)

    1996-03-01

    We present estimates of global energy efficiency by applying second-law (exergy) analysis to regional and global energy balances. We use a uniform analysis of national and regional energy balances and aggregate these balances first for three main economic regions and subsequently into world totals. The procedure involves assessment of energy and exergy efficiencies at each step of energy conversion, from primary exergy to final and useful exergy. Ideally, the analysis should be extended to include actual delivered energy services; unfortunately, data are scarce and only rough estimates can be given for this last stage of energy conversion. The overall result is that the current global primary to useful exergy efficiency is about one-tenth of the theoretical maximum and the service efficiency is even lower. (Author)

  18. [Single intravenous tranexamic acid dose to reduce blood loss in primary total knee replacement].

    Science.gov (United States)

    Sanz-Reig, J; Parra Ruiz, B; Ferrández Martínez, J; Martínez López, J F

    2016-01-01

    To evaluate the effectiveness and safety of a single intravenous dose of tranexamic acid in order to reduce blood loss in total knee replacement. Prospective observational study of the administration of tranexamic acid in patients undergoing primary total knee arthroplasty from November 2013 to February 2015, in which an autologous blood recovery system was used. The study included 98 patients, distributed into two groups of 49 patients according to whether or not they received intravenous tranexamic acid. The primary endpoint was the number of patients requiring autologous transfusion from the recovery system autologous blood recovery system. No drop-outs were recorded during follow-up. There were no significant differences between groups as regards the preoperative and hospital variables. The mean preoperative haemoglobin and haematocrit at 24 and 48 hours postoperatively were similar in both groups. The average volume of bleeding in the autologous blood recovery system and estimated average blood loss was lower in patients who had been administered tranexamic acid, with significant differences. No patients in the group that was administered tranexamic acid required blood autotransfusion. The transfusion rate was zero in the two groups. No adverse events related to the administration of tranexamic acid were recorded. Intravenous administration of tranexamic acid, according to the described protocol, has presented a non-autotransfusion or allo-transfusion rate of 100%, with no increased incidence of thrombotic events. Thus, its use in this group of patients is recommended. The indication should be individualized, its use justified in the patient medical records, and informed consent is mandatory. Copyright © 2015 SECOT. Published by Elsevier Espana. All rights reserved.

  19. The renewable energies in France: the main results in 2006; Les energies renouvelables en France: les principaux resultats en 2006

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2007-07-01

    The main results presented in the renewable energies annual evaluation are discussed: the production of electricity from renewable energy sources, the thermal production from renewable energy sources, the consumption of thermal renewable energies and statistical data from 2004 to 2006 on the total primary energy, the hydroelectricity, the solar energy, the geothermal energy, the heat pump, the wood energy, the cogeneration, the biogas the wind energy and the biofuels. (A.L.B.)

  20. Dependence of the quasipotential on the total energy of a two-particle system

    International Nuclear Information System (INIS)

    Kapshai, V.N.; Savrin, V.I.; Skachkov, N.B.

    1987-01-01

    For a system of two relativistic particles described in the Logunov-Tavkhelidze one-time approach the dependence of the quasipotential of one-boson exchange on the total energy of the system is calculated. It is shown that despite the nonlocal form of the obtained quasipotential the three-dimensional equations for the waves function can be reduced by a partial expansion to one-dimensional equations. The influence of the energy dependence of the quasipotential on its behavior in the coordinate representation is discussed

  1. Emerging Energy-Efficient Technologies in Buildings Technology Characterizations for Energy Modeling

    Energy Technology Data Exchange (ETDEWEB)

    Hadley, SW

    2004-10-11

    The energy use in America's commercial and residential building sectors is large and growing. Over 38 quadrillion Btus (Quads) of primary energy were consumed in 2002, representing 39% of total U.S. energy consumption. While the energy use in buildings is expected to grow to 52 Quads by 2025, a large number of energy-related technologies exist that could curtail this increase. In recent years, improvements in such items as high efficiency refrigerators, compact fluorescent lights, high-SEER air conditioners, and improved building shells have all contributed to reducing energy use. Hundreds of other technology improvements have and will continue to improve the energy use in buildings. While many technologies are well understood and are gradually penetrating the market, more advanced technologies will be introduced in the future. The pace and extent of these advances can be improved through state and federal R&D. This report focuses on the long-term potential for energy-efficiency improvement in buildings. Five promising technologies have been selected for description to give an idea of the wide range of possibilities. They address the major areas of energy use in buildings: space conditioning (33% of building use), water heating (9%), and lighting (16%). Besides describing energy-using technologies (solid-state lighting and geothermal heat pumps), the report also discusses energy-saving building shell improvements (smart roofs) and the integration of multiple energy service technologies (CHP packaged systems and triple function heat pumps) to create synergistic savings. Finally, information technologies that can improve the efficiency of building operations are discussed. The report demonstrates that the United States is not running out of technologies to improve energy efficiency and economic and environmental performance, and will not run out in the future. The five technology areas alone can potentially result in total primary energy savings of between 2 and

  2. An analysis of cross-sectional variations in total household energy requirements in India using micro survey data

    International Nuclear Information System (INIS)

    Pachauri, Shonali

    2004-01-01

    Using micro level household survey data from India, we analyse the variation in the pattern and quantum of household energy requirements, both direct and indirect, and the factors causing such variation. An econometric analysis using household survey data from India for the year 1993-1994 reveals that household socio-economic, demographic, geographic, family and dwelling attributes influence the total household energy requirements. There are also large variations in the pattern of energy requirements across households belonging to different expenditure classes. Results from the econometric estimation show that total household expenditure or income level is the most important explanatory variable causing variation in energy requirements across households. In addition, the size of the household dwelling and the age of the head of the household are related to higher household energy requirements. In contrast, the number of members in the household and literacy of the head are associated with lower household energy requirements

  3. An analysis of cross-sectional variations in total household energy requirements in India using micro survey data

    Energy Technology Data Exchange (ETDEWEB)

    Pachauri, Shonali E-mail: shonali.pachauri@cepe.mavt.ethz.ch

    2004-10-01

    Using micro level household survey data from India, we analyse the variation in the pattern and quantum of household energy requirements, both direct and indirect, and the factors causing such variation. An econometric analysis using household survey data from India for the year 1993-1994 reveals that household socio-economic, demographic, geographic, family and dwelling attributes influence the total household energy requirements. There are also large variations in the pattern of energy requirements across households belonging to different expenditure classes. Results from the econometric estimation show that total household expenditure or income level is the most important explanatory variable causing variation in energy requirements across households. In addition, the size of the household dwelling and the age of the head of the household are related to higher household energy requirements. In contrast, the number of members in the household and literacy of the head are associated with lower household energy requirements.

  4. Universal trend for heavy-ion total reaction cross sections at energies above the Coulomb barrier

    International Nuclear Information System (INIS)

    Tavares, O.A.P.; Medeiros, E.L.; Morcelle, V.

    2010-06-01

    Heavy-ion total reaction cross section measurements for more than one thousand one hundred reaction cases covering 61 target nuclei in the range 6 Li- 238 U, and 158 projectile nuclei from 2 H up to 84 Kr (mostly exotic ones) have been analysed in a systematic way by using an empirical, three-parameter formula which is applicable to cases for projectile kinetic energies above the Coulomb barrier. The analysis has shown that the average total nuclear binding energy per nucleon of the interacting nuclei and their radii are the chief quantities which describe the cross section patterns. A great number of cross section data (87%) has been quite satisfactorily reproduced by the proposed formula, therefore total reaction cross section predictions for new, not yet experimentally investigated reaction cases can be obtained within 25 percent (or much less) of uncertainty (author)

  5. Geothermal energy in the world energy scenario

    International Nuclear Information System (INIS)

    Barbier, E.

    1989-01-01

    This paper reports on the world energy consumption between 1960 and 1984 from primary energy sources (coal, natural gas, oil, hydropower, nuclear energy) and the same in percentages from 1925. This highlights the diminishing role of coal and the increased consumption of gas and oil. The latter has stabilized around 42% of the total after the drop in demand resulting from the oil crisis of 1973. The world energy consumption has then been divided into industrialized and developing countries. It appears that the latter, with a population equal to 68% of the total world population, consumed 23% of the world energy in 1982. Furthermore, the consumption figures show that the demand for domestic energy is much smaller in developing countries, and it is well-known that domestic energy consumed is one of the parameters used to assess standard of living. The total installed electric capacity throughout the world is then reported, divided between developed and developing countries, showing that the latter consumed 11% of all the electricity generated in the world in 1981. The world installed electric power of geothermal origin at the end of 1985 is shown, along with estimates for 1990. Geothermal energy represents 0.2% of the world electric power. This is obviously a small figure and indicates that geothermal energy plays a minor role on the world energy scene. However, if we distinguish between industrialized and developing countries, we can observe that, with their currently limited electrical consumption but good geothermal prospects, the developing countries could achieve quite a significant contribution to their total electric energy from that of geothermal origin, increasing at the moment from 3 to 19%. Finally, a comparison is made between electricity generating costs of different sources, showing that geothermal energy is competitive. A table illustrates the world evolution in installed geothermal capacity from 1950 to 1985. The non-electric uses of geothermal energy

  6. Total Energy. Sustainable cooling and heating in supermarkets; Total Energy. Duurzame koeling en verwarming supermarkten

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2011-03-15

    In 8 articles attention is paid to different aspects of cooling and heating in supermarkets: new coolants in the food retail sector, the climate plan of the Dutch Food Retail Association (CBL), he Round Table discussion with between CBL and supermarket chains about research results, approach and targets, the use of CO2 refrigeration in supermarkets, leakage of coolants from refrigerators and freezers in Dutch supermarkets, the energy efficient and environment-friendly refrigerator and freezer equipment of the distribution centre of supermarket chain C1000 in Raalte, Netherlands, changes for cooling techniques in the EIA energy list (Energy investment deduction scheme) and finally education options for the refrigeration industry in the Netherlands. [Dutch] In 8 artikelen wordt aandacht geschonken aan verschillende aspecten m.b.t. koeling en verwarming in supermarkten: nieuwe koelmiddelen in de 'food retail sector, het klimaatplan van de brancheorganisatie Centraal Bureau Levensmiddelenhandel (CBL), het Rondetafel overleg met de CBL en supermarktketens over onderzoeksresultaten, aanpak en doelen, de toepassing van CO2 koeling in supermarkten, lekkage van koelmiddelen uit koel- en vriesinstallaties in Nederlandse supermarkten, de energiezuinige en milieuvriendelijke koel-vriesinstallatie van het distributiecentrum van de supermarktketen C1000 in Raalte, wijzigingen voor koeltechniek in de EIA energielijst (Energie Investeringsaftrek subsidieregeling), en tenslotte opleidingsmogelijkheden voor de koeltechnische sector in Nederland.

  7. Energies and raw materials. The energy situation

    International Nuclear Information System (INIS)

    1997-11-01

    Statistics are given on the energy and raw materials (coal, oil, etc.) production and consumption levels in France in November 1997: primary energy total consumption has increased (mobile year) of 0.6%, at a slightly inferior rate than the rate since 3 years. Interior demand has varied depending on the energy: strong decrease for coal (- 9.3%), slight increase for petroleum products (+ 1.2%), markedly slowing down increase for gas (+ 1.4%) and moderate increase for electricity (+ 1.3%). An increase in the dollar exchange rate and a high level of oil and gas imports have induced a maintained high energy cost level with + 14% on one year, reaching 86.8 billions Francs, to be compared to 76.1 in November 1996

  8. India [National and regional programmes on the production of hydrogen using nuclear energy

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2013-03-15

    India's energy consumption has been increasing at a rapid pace in recent years due to population growth and economic development. In terms of primary energy consumption, at 595 Mtoe in 2007, despite a low per capita energy consumption rate, India ranks fifth in the world, accounting for about 3.5% of the global commercial energy demand in 2003. Until the end of the 1980s, India's energy policy was mainly based on the availability of indigenous resources. Coal, oil and natural gas are the three primary commercial energy sources. India has the world's third largest coal reserves after the USA and China; still, the existing demand exceeds the supply. Coal accounts for 41% (as of 2007) of India's total energy consumption, followed by renewables including hydroelectric power (29%), oil (24%) and natural gas (6%). Although nuclear power comprises only 1% of total energy consumption, it is expected to increase in the future. A large share of the total energy requirement is met by non-commercial energy sources, which include wood, crop residue and animal waste. But commercial energy of a much higher quality and efficiency are steadily replacing the traditional energy resources being consumed mainly in the rural sector. Of India's total energy needs, 30% are met through imports.

  9. Recent energy studies and energy policies in Turkey

    Energy Technology Data Exchange (ETDEWEB)

    Gullu, D.; Caglar, A.; Akdeniz, F. [Karadeniz Technical University, Trabzon (Turkey). Faculty of Education

    2001-07-01

    Currently, considerable attention has been focused on the energy sources and energy studies in Turkey. Indigenous energy consumption accounts for 37% of total energy consumption. The Turkish government's investment needs in the energy sector for the period 2000-2010 will be around 55 billion US dollars. Of this, about 81% is total planning investments. Conventional financing of major infrastructure projects would only increase the amount of foreign credit, thus the Ministry of Energy and Natural Resources (MENR) has conceived other options for financing projects. One option is the so-called Build, Operate, and Transfer (BOT) model, where private investors build and operate private sector generation for certain number of years, at which point they transfer ownership to the state. In June 1996, MENR introduced the Build, Own, and Operate (BOO) financing model. A major dilemma now faced by Turkey is how to invest in new electric power capacity while at the same time adhering to foreign debt ceilings to under lending rules set by the International Monetary Fund. Turkey has to adopt new long-term energy strategies to reduce the share of fossil fuels in the primary energy consumption. Recently, the development of alternative energy sources has been a major focus of the research effort in Turkey.

  10. Intravenous versus topical tranexamic acid administration in primary total knee arthroplasty: a meta-analysis.

    Science.gov (United States)

    Shin, Young-Soo; Yoon, Jung-Ro; Lee, Hoon-Nyun; Park, Se-Hwan; Lee, Dae-Hee

    2017-11-01

    This meta-analysis was designed to compare the effectiveness and safety of intravenous (IV) versus topical administration of tranexamic acid (TXA) in patients undergoing primary total knee arthroplasty (TKA) by evaluating the need for allogenic blood transfusion, incidence of postoperative complications, volume of postoperative blood loss, and change in haemoglobin levels. Studies were included in this meta-analysis to check whether they assessed the allogenic blood transfusion rate, postoperative complications including pulmonary thromboembolism (PTE) or deep vein thrombosis (DVT), volume of postoperative blood loss via drainage, estimated blood loss, total blood loss, and change in haemoglobin levels before and after surgery in primary TKA with TXA administered through both the IV and topical routes. Ten studies were included in this meta-analysis. The proportion of patients requiring allogenic blood transfusion (OR 1.34, 95 % CI 0.63-2.81; n.s.) and the proportion of patients who developed postoperative complications including PTE or DVT (OR 0.85, 95 % CI 0.41 to 1.77; n.s.) did not significantly differ between the two groups. There was 52.3 mL less blood loss via drainage (95 % CI -50.74 to 185.66 mL; n.s.), 52.1 mL greater estimated blood loss (95 % CI -155.27 to 51.03 mL; n.s.), and 51.4 mL greater total blood loss (95 % CI -208.16 to 105.31 mL; n.s.) in the topical TXA group as compared to the IV TXA group. The two groups were also similar in terms of the change in haemoglobin levels (0.02 g/dL, 95 % CI -0.36 to 0.39 g/dL; n.s.). In primary TKA, there are no significant differences in the transfusion requirement, postoperative complications, blood loss, and change in haemoglobin levels between the IV and topical administration of TXA. In addition, results from subgroup analysis evaluating the effect of the times of TXA administration through the IV route suggested that double IV dose of TXA is more effective than single dose in terms of the

  11. Energies and raw materials. The energy situation; Energies et matieres premieres. Conjoncture energetique

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-11-01

    Statistics are given on the energy and raw materials (coal, oil, etc.) production and consumption levels in France in November 1997: primary energy total consumption has increased (mobile year) of 0.6%, at a slightly inferior rate than the rate since 3 years. Interior demand has varied depending on the energy: strong decrease for coal (- 9.3%), slight increase for petroleum products (+ 1.2%), markedly slowing down increase for gas (+ 1.4%) and moderate increase for electricity (+ 1.3%). An increase in the dollar exchange rate and a high level of oil and gas imports have induced a maintained high energy cost level with + 14% on one year, reaching 86.8 billions Francs, to be compared to 76.1 in November 1996

  12. Research report of fiscal 1997. Study on total energy and material control (feasibility study on circulating society); 1997 nendo chosa hokokusho. Total energy and material control ni kansuru chosa (junkangata shakai kochiku kanosei chosa) chosa hokokusho

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-03-01

    In order to construct real sustainable global environment and human society in the 21st century called the century of environment, not only the innovation of manufacturing processes technically supporting such the construction but also the conception including the innovation of the whole society from a wide viewpoint are essential. As a total energy and material control system (TEMCOS) concept, the view of an energy-saving circulating society is attempted which minimizes a total energy and material flow in Japan, and the role and issue of manufacturing industry, in particular, material industry are extracted. As one of the targets of such a concept, the conception of an eco-town is also described. Paying attention on some important material industries including a mass material flow and consuming a large amount of energy such as metal, plastics and automobile industries, the study result on a material flow for every industry is arranged, and some effective issues contributing to minimize a material flow and control energy consumption and CO2 emission are extracted. 80 refs., 67 figs., 30 tabs.

  13. Total cross sections of hadron interactions at high energies in low constituents number model

    International Nuclear Information System (INIS)

    Abramovskij, V.A.; Radchenko, N.V.

    2009-01-01

    We consider QCD hadrons interaction model in which gluons density is low in initial state wave function in rapidity space and real hadrons are produced from color strings decay. In this model behavior of total cross sections of pp, pp bar, π ± p, K ± p, γp, and γγ interactions is well described. The value of proton-proton total cross section at LHC energy is predicted

  14. The impact of food and nutrient-based standards on primary school children's lunch and total dietary intake: a natural experimental evaluation of government policy in England.

    Science.gov (United States)

    Spence, Suzanne; Delve, Jennifer; Stamp, Elaine; Matthews, John N S; White, Martin; Adamson, Ashley J

    2013-01-01

    In 2005, the nutritional content of children's school lunches in England was widely criticised, leading to a major policy change in 2006. Food and nutrient-based standards were reintroduced requiring primary schools to comply by September 2008. We aimed to determine the effect of the policy on the nutritional content at lunchtime and in children's total diet. We undertook a natural experimental evaluation, analysing data from cross-sectional surveys in 12 primary schools in North East England, pre and post policy. Dietary data were collected on four consecutive days from children aged 4-7 years (n = 385 in 2003-4; n = 632 in 2008-9). We used linear mixed effect models to analyse the effects of gender, year, and lunch type on children's mean total daily intake. Both pre- and post-implementation, children who ate a school lunch consumed less sodium (mean change -128 mg, 95% CI: -183 to -73 mg) in their total diet than children eating home-packed lunches. Post-implementation, children eating school lunches consumed a lower % energy from fat (-1.8%, -2.8 to -0.9) and saturated fat (-1.0%; -1.6 to -0.5) than children eating packed lunches. Children eating school lunches post implementation consumed significantly more carbohydrate (16.4 g, 5.3 to 27.6), protein (3.6 g, 1.1 to 6.0), non-starch polysaccharides (1.5 g, 0.5 to 1.9), vitamin C (0.7 mg, 0.6 to 0.8), and folate (12.3 µg, 9.7 to 20.4) in their total diet than children eating packed lunches. Implementation of school food policy standards was associated with significant improvements in the nutritional content of school lunches; this was reflected in children's total diet. School food- and nutrient-based standards can play an important role in promoting dietary health and may contribute to tackling childhood obesity. Similar policy measures should be considered for other environments influencing children's diet.

  15. The impact of food and nutrient-based standards on primary school children's lunch and total dietary intake: a natural experimental evaluation of government policy in England.

    Directory of Open Access Journals (Sweden)

    Suzanne Spence

    Full Text Available In 2005, the nutritional content of children's school lunches in England was widely criticised, leading to a major policy change in 2006. Food and nutrient-based standards were reintroduced requiring primary schools to comply by September 2008. We aimed to determine the effect of the policy on the nutritional content at lunchtime and in children's total diet. We undertook a natural experimental evaluation, analysing data from cross-sectional surveys in 12 primary schools in North East England, pre and post policy. Dietary data were collected on four consecutive days from children aged 4-7 years (n = 385 in 2003-4; n = 632 in 2008-9. We used linear mixed effect models to analyse the effects of gender, year, and lunch type on children's mean total daily intake. Both pre- and post-implementation, children who ate a school lunch consumed less sodium (mean change -128 mg, 95% CI: -183 to -73 mg in their total diet than children eating home-packed lunches. Post-implementation, children eating school lunches consumed a lower % energy from fat (-1.8%, -2.8 to -0.9 and saturated fat (-1.0%; -1.6 to -0.5 than children eating packed lunches. Children eating school lunches post implementation consumed significantly more carbohydrate (16.4 g, 5.3 to 27.6, protein (3.6 g, 1.1 to 6.0, non-starch polysaccharides (1.5 g, 0.5 to 1.9, vitamin C (0.7 mg, 0.6 to 0.8, and folate (12.3 µg, 9.7 to 20.4 in their total diet than children eating packed lunches. Implementation of school food policy standards was associated with significant improvements in the nutritional content of school lunches; this was reflected in children's total diet. School food- and nutrient-based standards can play an important role in promoting dietary health and may contribute to tackling childhood obesity. Similar policy measures should be considered for other environments influencing children's diet.

  16. Total integrated energy system (TIES) feasibility analysis for the downtown redevelopment project, Pasadena, California

    Energy Technology Data Exchange (ETDEWEB)

    None

    1977-04-01

    The purpose of this study is to determine the most desirable method of serving the energy needs of a commercial development to be constructed in Pasadena, California. The factors that determine maximum desirability consist of the following: (1) maximum economic benefit to the energy user and to the surrounding community; (2) minimum usage of energy by both the energy user and the surrounding community; and (3) minimum introduction of pollutants into the community. The methods studied were the Total Integrated Energy System (TIES) concept in several configurations. The TIES concept differs from the ''total energy concept'' in the respect that the electric power output of the local power generation plant goes into the utility company distribution grid, rather than to the user. The user is served power from the grid, as with a conventional system, but also receives heating and cooling media produced from power generation by-product heat from the TIES plant. The effect of this concept is that a very large source-sink for electric energy is provided by the utility company grid. This, in turn, permits the plant to operate in response to instantaneous thermal demand, rather than instantaneous power demand. No auxiliary firing is ever required. No waste of unneeded by-product energy to atmosphere ever occurs. Balance is achieved by either delivering excess power into the grid or by withdrawing power production deficiency from the grid. Near-optimum efficiency is achieved during all operating conditions. There is no need whatsoever for the power-generating plant to be sized to meet the power demand, since it seldom, if ever, tracks the power demand. Sizing of the electric generation is solely a function of economics and the demand for waste heat.

  17. Monte-Carlo study on primary knock-on atom energy spectrum produced by neutron radiation

    International Nuclear Information System (INIS)

    Zhou Wei; Liu Yongkang; Deng Yongjun; Ma Jimin

    2012-01-01

    Computational method on energy distribution of primary knock-on atom (PKA) produced by neutron radiation was built in the paper. Based on the DBCN card in MCNP, reaction position, reaction type and energy transfer between neutrons and atoms were recorded. According to statistic of these data, energy and space distributions of PKAs were obtained. The method resolves preferably randomicity of random number and efficiency of random sampling computation. The results show small statistical fluctuation and well statistical. Three-dimensional figure of energy and space distribution of PKAs were obtained, which would be important to evaluate radiation capability of materials and study radiation damage by neutrons. (authors)

  18. Structure determination of disordered organic molecules on surfaces from the Bragg spots of low-energy electron diffraction and total energy calculations

    International Nuclear Information System (INIS)

    Poon, H.C.; Weinert, M.; Saldin, D.K.; Stacchiola, D.; Zheng, T.; Tysoe, W.T.

    2004-01-01

    We show that an analysis of the intensity versus energy variation of Bragg spots due to low-energy electron diffraction from a disordered overlayer of molecules on a crystal surface allows a much more convenient method of determining the local adsorption geometries of such molecules than previously analyzed weak diffuse diffraction patterns. For the case of methanol on Pd(111), we show that the geometry determined by this means from experimental diffraction data is in excellent agreement with the predictions of density functional total energy calculations

  19. Rhabdomyosarcoma cells show an energy producing anabolic metabolic phenotype compared with primary myocytes

    Directory of Open Access Journals (Sweden)

    Higashi Richard M

    2008-10-01

    Full Text Available Abstract Background The functional status of a cell is expressed in its metabolic activity. We have applied stable isotope tracing methods to determine the differences in metabolic pathways in proliferating Rhabdomysarcoma cells (Rh30 and human primary myocytes in culture. Uniformly 13C-labeled glucose was used as a source molecule to follow the incorporation of 13C into more than 40 marker metabolites using NMR and GC-MS. These include metabolites that report on the activity of glycolysis, Krebs' cycle, pentose phosphate pathway and pyrimidine biosynthesis. Results The Rh30 cells proliferated faster than the myocytes. Major differences in flux through glycolysis were evident from incorporation of label into secreted lactate, which accounts for a substantial fraction of the glucose carbon utilized by the cells. Krebs' cycle activity as determined by 13C isotopomer distributions in glutamate, aspartate, malate and pyrimidine rings was considerably higher in the cancer cells than in the primary myocytes. Large differences were also evident in de novo biosynthesis of riboses in the free nucleotide pools, as well as entry of glucose carbon into the pyrimidine rings in the free nucleotide pool. Specific labeling patterns in these metabolites show the increased importance of anaplerotic reactions in the cancer cells to maintain the high demand for anabolic and energy metabolism compared with the slower growing primary myocytes. Serum-stimulated Rh30 cells showed higher degrees of labeling than serum starved cells, but they retained their characteristic anabolic metabolism profile. The myocytes showed evidence of de novo synthesis of glycogen, which was absent in the Rh30 cells. Conclusion The specific 13C isotopomer patterns showed that the major difference between the transformed and the primary cells is the shift from energy and maintenance metabolism in the myocytes toward increased energy and anabolic metabolism for proliferation in the Rh30 cells

  20. Effect of tranexamic acid administration on bleeding in primary total hip arthroplasty.

    Science.gov (United States)

    Fernández-Cortiñas, A B; Quintáns-Vázquez, J M; Gómez-Suárez, F; Murillo, O Simón; Sánchez-López, B R; Pena-Gracía, J M

    To study the efficacy of tranexamic acid to decrease perioperative bleeding in patients who have undergone a total hip arthroplasty operation and to evaluate drug safety. Observational, prospective, controlled and randomized study on the efficacy of tranexamic acid as a method to reduce bleeding in primary hip replacement surgery. We included 134 patients operated during 2014 in our centre, who were divided into 2 groups according to whether or not they had received tranexamic acid. The main study variables were haemoglobin and haematocrit levels, the amount of blood collected from the post-operative drain in the first 12, 24 and 48hours and transfusion requirements. Post-operative haemoglobin and haematocrit levels were statistically higher (Ptranexamic acid. Statistically significant differences (P=.001) were found as to the need for transfusion according to group, more transfusions were performed in the cohort that had not received tranexamic acid: 25.37% compared to 4.48% for the group with tranexamic acid. No adverse events related to administration of tranexamic acid were recorded. Administration of tranexamic acid has proved to be an effective and safe method to reduce peri-operative bleeding in patients who underwent total hip arthroplasty and avoids allogenic blood transfusion. Therefore, tranexamic acid treatment could entail a financial saving for the healthcare system and expose the patient to less risk. Copyright © 2017 SECOT. Publicado por Elsevier España, S.L.U. All rights reserved.

  1. Universal trend for heavy-ion total reaction cross sections at energies above the Coulomb barrier

    Energy Technology Data Exchange (ETDEWEB)

    Tavares, O.A.P.; Medeiros, E.L., E-mail: emil@cbpf.b [Centro Brasileiro de Pesquisas Fisicas (CBPF), Rio de Janeiro, RJ (Brazil); Morcelle, V. [Universidade de Sao Paulo (IF/USP), SP (Brazil). Inst. de Fisica

    2010-06-15

    Heavy-ion total reaction cross section measurements for more than one thousand one hundred reaction cases covering 61 target nuclei in the range {sup 6}Li-{sup 238}U, and 158 projectile nuclei from {sup 2}H up to {sup 84}Kr (mostly exotic ones) have been analysed in a systematic way by using an empirical, three-parameter formula which is applicable to cases for projectile kinetic energies above the Coulomb barrier. The analysis has shown that the average total nuclear binding energy per nucleon of the interacting nuclei and their radii are the chief quantities which describe the cross section patterns. A great number of cross section data (87%) has been quite satisfactorily reproduced by the proposed formula, therefore total reaction cross section predictions for new, not yet experimentally investigated reaction cases can be obtained within 25 percent (or much less) of uncertainty (author)

  2. About total kinetic energy distribution between fragments of binary fission

    International Nuclear Information System (INIS)

    Khugaev, A.V.; Koblik, Yu.N.; Pikul, V.P.; Ioannou, P.; Dimovasili, E.

    2002-01-01

    At the investigation of binary fission reactions one of the main characteristic of process is total kinetic energy (TKE) of fission fragments and it distribution between them. From the values of these characteristics it is possible to extract the information about structure of fission fragments in the break up point of initial fissionable nuclear system. In our work TKE dependence from the deformation parameters of shape and density distribution of charge in the fission fragments are investigated. In the end of paper some generalizations of obtaining results are carried out and presented in the form of tables and figures

  3. Energy embodied in the international trade of China. An energy input-output analysis

    International Nuclear Information System (INIS)

    Liu, Hongtao; Xi, Youmin; Guo, Ju'e; Li, Xia

    2010-01-01

    Growing international trade has not only positively affected the People's Republic of China's (China's) economic development, but also expanded the exportation of energy embodied in goods during their production. This energy flow out will pose risks to China's rational utilization of natural resources as well as environmental protection. In this paper, we evaluate the energy embodied in goods produced in China during 1992-2005 and use input-output structural decomposition analysis to identify five key factors causing the changes of energy embodied in exports. (Direct primary energy efficiency, primary energy consumption structure, structure of intermediate inputs, structure of exports, and scale of exports.) For the three sub-periods of 1992-1997, 1997-2002, and 2002-2005, results show that China is a net exporter of energy, and the energy embodied in exports tends to increase over time. The expanding total volume of exports and increasing exports of energy-intensive goods tend to enlarge the energy embodied in exports within all three sub-periods, but these driving forces were offset by a considerable improvement of energy efficiency and changes in primary energy consumption structure from 1992 to 2002 and the effects of structure of intermediate input only in the sub-period from 1992 to 1997. From 2002 to 2005, the sharp augmentation of energy embodied in exports was driven by all the five factors. Our research has practical implications for the Chinese economy. Results of this study suggest that the energy embodied in trade should receive special attentions in energy policies design to limit the energy resource out-flow and pollution generation. (author)

  4. Effect of hydroxyapatite coating on risk of revision after primary total hip arthroplasty in younger patients: findings from the Danish Hip Arthroplasty Registry

    DEFF Research Database (Denmark)

    Paulsen, Aksel; Pedersen, Alma B; Johnsen, Søren P

    2007-01-01

    BACKGROUND: The effect of hydroxyapatite (HA) on implant survival in the medium and long term is uncertain. We studied the effect of HA coating of uncemented implants on the risk of cup and stem revision in primary total hip arthroplasty (THA). PATIENTS AND METHODS: Using the Danish Hip Arthropla......BACKGROUND: The effect of hydroxyapatite (HA) on implant survival in the medium and long term is uncertain. We studied the effect of HA coating of uncemented implants on the risk of cup and stem revision in primary total hip arthroplasty (THA). PATIENTS AND METHODS: Using the Danish Hip...

  5. Total photoabsorption cross section on nuclei measured in energy range 0.5-2.6 GeV

    International Nuclear Information System (INIS)

    Mirazita, M.

    1998-03-01

    The total photoabsorption cross section on several nuclei has been measured in the energy range 0.5 - 2.6 GeV. Nuclear data show a significant reduction of the absorption strength with respect to the free nucleon case suggesting a shadowing effect at low energies

  6. Is There an Association Between Smoking Status and Prosthetic Joint Infection After Primary Total Joint Arthroplasty?

    Science.gov (United States)

    Gonzalez, Amanda I; Luime, Jolanda J; Uçkay, Ilker; Hannouche, Didier; Hoffmeyer, Pierre; Lübbeke, Anne

    2018-02-23

    Recent reports highlighted the association between smoking and higher risk of postsurgical infections. The aim was to compare the incidence of prosthetic joint infection after primary total joint arthroplasty (TJA) according to smoking status. A prospective hospital registry-based cohort study was performed including all primary knee and hip TJAs performed between March 1996 and December 2013. Smoking status preoperatively was classified into never, former, and current smoker. Incidence rates and hazard ratios (HRs) for prosthetic joint infection according to smoking status were assessed within the first year and beyond. We included 8559 primary TJAs (mean age 69.5 years), and median follow-up was 67 months. There were 5722 never, 1315 former, and 1522 current smokers. Incidence rates of infection within the first year for never, former, and current smokers were, respectively, 4.7, 10.1, and 10.9 cases/1000 person-years, comparing ever vs never smokers, crude and adjusted HRs were 2.35 (95% confidence interval [CI] 1.39-3.98) and 1.8 (95% CI 1.04-3.2). Beyond the first year, crude and adjusted HRs were 1.37 (95% CI 0.78-2.39) and 1.12 (95% CI 0.61-2.04). Smoking increased the infection risk about 1.8 times after primary hip or knee TJA in both current and former smokers. Beyond the first year, the infection risk was similar to never smokers. Copyright © 2018 Elsevier Inc. All rights reserved.

  7. Postprandial appetite ratings are reproducible and moderately related to total day energy intakes, but not ad libitum lunch energy intakes, in healthy young women.

    Science.gov (United States)

    Tucker, Amy J; Heap, Sarah; Ingram, Jessica; Law, Marron; Wright, Amanda J

    2016-04-01

    Reproducibility and validity testing of appetite ratings and energy intakes are needed in experimental and natural settings. Eighteen healthy young women ate a standardized breakfast for 8 days. Days 1 and 8, they rated their appetite (Hunger, Fullness, Desire to Eat, Prospective Food Consumption (PFC)) over a 3.5 h period using visual analogue scales, consumed an ad libitum lunch, left the research center and recorded food intake for the remainder of the day. Days 2-7, participants rated their at-home Hunger at 0 and 30 min post-breakfast and recorded food intake for the day. Total area under the curve (AUC) over the 180 min period before lunch, and energy intakes were calculated. Reproducibility of satiety measures between days was evaluated using coefficients of repeatability (CR), coefficients of variation (CV) and intra-class coefficients (ri). Correlation analysis was used to examine validity between satiety measures. AUCs for Hunger, Desire to Eat and PFC (ri = 0.73-0.78), ad libitum energy intakes (ri = 0.81) and total day energy intakes (ri​ = 0.48) were reproducible; fasted ratings were not. Average AUCs for Hunger, Desire to Eat and PFC, Desire to Eat at nadir and PFC at fasting, nadir and 180 min were correlated to total day energy intakes (r = 0.50-0.77, P < 0.05), but no ratings were correlated to lunch consumption. At-home Hunger ratings were weakly reproducible but not correlated to reported total energy intakes. Satiety ratings did not concur with next meal intake but PFC ratings may be useful predictors of intake. Overall, this study adds to the limited satiety research on women and challenges the accepted measures of satiety in an experimental setting. Copyright © 2016 Elsevier Ltd. All rights reserved.

  8. Has Health Care Reform Legislation Reduced the Economic Burden of Hospital Readmissions Following Primary Total Joint Arthroplasty?

    Science.gov (United States)

    Kurtz, Steven M; Lau, Edmund C; Ong, Kevin L; Adler, Edward M; Kolisek, Frank R; Manley, Michael T

    2017-11-01

    The purpose of this study was to determine whether the cost of readmissions after primary total hip and knee arthroplasty (THA and TKA) has decreased since the introduction of health care reform legislation and what patient, clinical, and hospital factors drive such costs. The 100% Medicare inpatient dataset was used to identify 1,654,602 primary THA and TKA procedures between 2010 and 2014. The per-patient cost of readmissions was evaluated in general linear models in which the year of surgery and patient, clinical, and hospital factors were treated as covariates in separate models for THA and TKA. The year-to-year risk of 90-day readmission was reduced by 2% and 4% (P total joint arthroplasty volume. The top 5 factors associated with the cost of 90-day TKA readmissions were (in rank order) the length of stay, hospital's teaching status, discharge disposition, patient's gender, and age. Although readmission rates declined slightly, the results of this study do not support the hypothesis that readmission costs have decreased since the introduction of health care reform legislation. Instead, we found that clinical and hospital factors were among the most important cost drivers. Copyright © 2017 Elsevier Inc. All rights reserved.

  9. Do Offshore Wind Farms Influence Marine Primary Production?

    Science.gov (United States)

    Tweddle, J. F.; Murray, R. B. O.; Gubbins, M.; Scott, B. E.

    2016-02-01

    Primary producers (phytoplankton) form the basis of marine food-webs, supporting production of higher trophic levels, and act as a sink of CO2. We considered the impact of proposed large scale offshore wind farms in moderately deep waters (> 45 m) off the east coast of Scotland on rates of primary production. A 2 stage modelling process was used, employing state-of-the-art 3-D hydrographic models with the ability to capture flow at the spatial resolution of 10 m combined with 1-D vertical modelling using 7 years of local forcing data. Through influencing the strength of stratification via changes in current flow, large (100 m) modelled wind turbine foundations had a significant effect on primary producers, consistently reducing total annual primary production, although within the range of natural interannual variability. The percentage reduction was largest over submarine banks less than 54 m in depth, and was outside the range of natural interannual variability. Smaller (10 m) turbine foundations had no discernible effect on total annual primary production. The results indicate that smaller foundations should be favored as a mitigation measure, in terms of effects on primary production, and this type of analysis should be considered within sectoral planning and licensing processes for future renewable energy developments.

  10. Windows with improved energy performance

    DEFF Research Database (Denmark)

    Noyé, Peter Anders; Laustsen, Jacob Birck; Svendsen, Svend

    2002-01-01

    According to the Danish energy protocol, Energy 21, one of the goals with highest priority is to reduce the CO2-emission. Energy consumption for domestic heating is a major contributor to the CO2-emission; hence one of the primary efforts to reach the goal is by saving energy in the households...... performances. During the last 20 years the U-value of the glazing part of windows has been improved considerably, but the frame part has not followed the same development with respect to energy performance. Therefore an increasingly large part of the total heat loss through windows is relating to the frame...... part, for which reason, as far as energy efficiency and total economy are concerned, it has become more interesting to further develop frame structures. Traditionally, the energy performance of windows has primarily been characterised by the heat loss coefficient, U-value. However as the heat loss has...

  11. Investigation of the heavy nuclei fission with anomalously high values of the fission fragments total kinetic energy

    Science.gov (United States)

    Khryachkov, Vitaly; Goverdovskii, Andrei; Ketlerov, Vladimir; Mitrofanov, Vecheslav; Sergachev, Alexei

    2018-03-01

    Binary fission of 232Th and 238U induced by fast neutrons were under intent investigation in the IPPE during recent years. These measurements were performed with a twin ionization chamber with Frisch grids. Signals from the detector were digitized for further processing with a specially developed software. It results in information of kinetic energies, masses, directions and Bragg curves of registered fission fragments. Total statistics of a few million fission events were collected during each experiment. It was discovered that for several combinations of fission fragment masses their total kinetic energy was very close to total free energy of the fissioning system. The probability of such fission events for the fast neutron induced fission was found to be much higher than for spontaneous fission of 252Cf and thermal neutron induced fission of 235U. For experiments with 238U target the energy of incident neutrons were 5 MeV and 6.5 MeV. Close analysis of dependence of fission fragment distribution on compound nucleus excitation energy gave us some explanation of the phenomenon. It could be a process in highly excited compound nucleus which leads the fissioning system from the scission point into the fusion valley with high probability.

  12. Primary radiation damage characterization of α-iron under irradiation temperature for various PKA energies

    Science.gov (United States)

    Sahi, Qurat-ul-ain; Kim, Yong-Soo

    2018-04-01

    The understanding of radiation-induced microstructural defects in body-centered cubic (BCC) iron is of major interest to those using advanced steel under extreme conditions in nuclear reactors. In this study, molecular dynamics (MD) simulations were implemented to examine the primary radiation damage in BCC iron with displacement cascades of energy 1, 5, 10, 20, and 30 keV at temperatures ranging from 100 to 1000 K. Statistical analysis of eight MD simulations of collision cascades were carried out along each [110], [112], [111] and a high index [135] direction and the temperature dependence of the surviving number of point defects and the in-cascade clustering of vacancies and interstitials were studied. The peak time and the corresponding number of defects increase with increasing irradiation temperature and primary knock-on atom (PKA) energy. However, the final number of surviving point defects decreases with increasing lattice temperature. This is associated with the increase of thermal spike at high PKA energy and its long timespan at higher temperatures. Defect production efficiency (i.e., surviving MD defects, per Norgett-Robinson-Torrens displacements) also showed a continuous decrease with the increasing irradiation temperature and PKA energy. The number of interstitial clusters increases with both irradiation temperature and PKA energy. However, the increase in the number of vacancy clusters with PKA energy is minimal-to-constant and decreases as the irradiation temperature increases. Similarly, the probability and cluster size distribution for larger interstitials increase with temperature, whereas only smaller size vacancy clusters were observed at higher temperatures.

  13. Energy in Croatia 2002. Annual Energy Report

    International Nuclear Information System (INIS)

    2003-01-01

    The review, in its own recognisable way, consists of the most recent and settled data on the Croatian energy system for the period up to and including the year 2002. Some data appertain to a longer time period with the aim of an easier insight into long-term prospects. In 2002 total primary energy supply exceeded the year before by 1.3 percent. Owing to the simultaneous growth of the gross domestic product by 5.2 percent, energy intensity decreased thus marking the third year of a positive trend. However, it has to be mentioned that energy intensity, which expresses the total energy consumed per unit of gross domestic product, exceeded the level of the developed European countries by 33 percent, although it was still more favourable than in the majority of transition countries. Supply from own sources fell to the less than 50 percent, and energy import, with oil in the leading position, recorded an average annual increase of 4.7 percent. In 2002 transformation losses as well as transportation and distribution losses decreased thus bringing about the already mentioned total energy consumption growth of 1.3 percent and final demand increase by 2.3 percent - this means that the energy system was more efficient. The year 2002 recorded a consumption increase in traffic by 6.2 percent, in other sectors by 3 percent, while industry realised a decrease by 3.9 percent. It should be emphasised that diesel fuel recorded a major increase and in the whole structure almost reached the level of the motor gasoline. From 1995 till the end of the period observed the gas distribution network was doubled in length. The report includes other interesting information about our energy system, i.e. capacities, energy, source prices, as well as environmental impact from the energy sector

  14. Total β-decay energies of neutron-rich zinc isotopes, A=75-80

    International Nuclear Information System (INIS)

    Lund, E.; Aleklett, K.; Fogelberg, B.; Sangariyavanish, A.

    1984-01-01

    The present investigation involves improved measurements of the Qsub(β)-values of 75-78 Zn and determinations of the total decay energies of sup(79,80)Zn which are not reported in the literature before. Also 81 Zn was detected but at the time for the experiment the ion-source was not efficient enough to yield sufficient activity for an accurate Qsub(β)-determination. (orig./HSI)

  15. Scatter correction using a primary modulator for dual energy digital radiography: A Monte Carlo simulation study

    Science.gov (United States)

    Jo, Byung-Du; Lee, Young-Jin; Kim, Dae-Hong; Kim, Hee-Joung

    2014-08-01

    In conventional digital radiography (DR) using a dual energy subtraction technique, a significant fraction of the detected photons are scattered within the body, making up the scatter component. Scattered radiation can significantly deteriorate image quality in diagnostic X-ray imaging systems. Various methods of scatter correction, including both measurement- and non-measurement-based methods, have been proposed in the past. Both methods can reduce scatter artifacts in images. However, non-measurement-based methods require a homogeneous object and have insufficient scatter component correction. Therefore, we employed a measurement-based method to correct for the scatter component of inhomogeneous objects from dual energy DR (DEDR) images. We performed a simulation study using a Monte Carlo simulation with a primary modulator, which is a measurement-based method for the DEDR system. The primary modulator, which has a checkerboard pattern, was used to modulate the primary radiation. Cylindrical phantoms of variable size were used to quantify the imaging performance. For scatter estimates, we used discrete Fourier transform filtering, e.g., a Gaussian low-high pass filter with a cut-off frequency. The primary modulation method was evaluated using a cylindrical phantom in the DEDR system. The scatter components were accurately removed using a primary modulator. When the results acquired with scatter correction and without scatter correction were compared, the average contrast-to-noise ratio (CNR) with the correction was 1.35 times higher than that obtained without the correction, and the average root mean square error (RMSE) with the correction was 38.00% better than that without the correction. In the subtraction study, the average CNR with the correction was 2.04 (aluminum subtraction) and 1.38 (polymethyl methacrylate (PMMA) subtraction) times higher than that obtained without the correction. The analysis demonstrated the accuracy of the scatter correction and the

  16. Total Water Intake from Beverages and Foods Is Associated with Energy Intake and Eating Behaviors in Korean Adults

    Science.gov (United States)

    Lee, Kyung Won; Shin, Dayeon; Song, Won O.

    2016-01-01

    Water is essential for the proper functioning of the body. Even though a recommendation exists for adequate water intake for Koreans, studies identifying actual water intake from all beverages and foods consumed daily in the Korean population are limited. Thus, we estimated total water intake from both beverages and foods and its association with energy intake and eating behaviors in Korean adults. We used a nationally representative sample of 25,122 Korean adults aged ≥19 years, from the Korean National Health and Nutrition Examination Survey 2008–2012. We performed multiple regression analyses, adjusting for sociodemographic and health-related variables to investigate the contribution of overall energy and dietary intakes and eating behaviors to total water intake. The mean total water intake excluding plain water was 1071 g (398 g from beverages and 673 g from foods) and the estimated plain water intake was 1.3 L. Among Korean adults, 82% consumed beverages (excluding plain water) and these beverages contributed to 10% of daily energy intake and 32% of total water intake from beverages and foods. For every 100 kcal/day in energy intake, water intake consumed through beverages and foods increased by 18 g and 31 g, respectively. Water intake from beverages and foods was positively associated with energy from fat and dietary calcium, but inversely associated with energy density and energy from carbohydrates. When there was a 5% increase in energy intake from snacks and eating outside the home, there was an increase in water intake from beverages of 13 g and 2 g, respectively. Increased daily energy intake, the number of eating episodes, and energy intake from snacks and eating outside the home predicted higher water intake from beverages and foods. Our results provide evidence suggesting that various factors, including sociodemographic status, dietary intakes, and eating behaviors, could be important contributors to the water intake of Korean adults. Findings

  17. Total Water Intake from Beverages and Foods Is Associated with Energy Intake and Eating Behaviors in Korean Adults

    Directory of Open Access Journals (Sweden)

    Kyung Won Lee

    2016-10-01

    Full Text Available Water is essential for the proper functioning of the body. Even though a recommendation exists for adequate water intake for Koreans, studies identifying actual water intake from all beverages and foods consumed daily in the Korean population are limited. Thus, we estimated total water intake from both beverages and foods and its association with energy intake and eating behaviors in Korean adults. We used a nationally representative sample of 25,122 Korean adults aged ≥19 years, from the Korean National Health and Nutrition Examination Survey 2008–2012. We performed multiple regression analyses, adjusting for sociodemographic and health-related variables to investigate the contribution of overall energy and dietary intakes and eating behaviors to total water intake. The mean total water intake excluding plain water was 1071 g (398 g from beverages and 673 g from foods and the estimated plain water intake was 1.3 L. Among Korean adults, 82% consumed beverages (excluding plain water and these beverages contributed to 10% of daily energy intake and 32% of total water intake from beverages and foods. For every 100 kcal/day in energy intake, water intake consumed through beverages and foods increased by 18 g and 31 g, respectively. Water intake from beverages and foods was positively associated with energy from fat and dietary calcium, but inversely associated with energy density and energy from carbohydrates. When there was a 5% increase in energy intake from snacks and eating outside the home, there was an increase in water intake from beverages of 13 g and 2 g, respectively. Increased daily energy intake, the number of eating episodes, and energy intake from snacks and eating outside the home predicted higher water intake from beverages and foods. Our results provide evidence suggesting that various factors, including sociodemographic status, dietary intakes, and eating behaviors, could be important contributors to the water intake of Korean

  18. Total Water Intake from Beverages and Foods Is Associated with Energy Intake and Eating Behaviors in Korean Adults.

    Science.gov (United States)

    Lee, Kyung Won; Shin, Dayeon; Song, Won O

    2016-10-04

    Water is essential for the proper functioning of the body. Even though a recommendation exists for adequate water intake for Koreans, studies identifying actual water intake from all beverages and foods consumed daily in the Korean population are limited. Thus, we estimated total water intake from both beverages and foods and its association with energy intake and eating behaviors in Korean adults. We used a nationally representative sample of 25,122 Korean adults aged ≥19 years, from the Korean National Health and Nutrition Examination Survey 2008-2012. We performed multiple regression analyses, adjusting for sociodemographic and health-related variables to investigate the contribution of overall energy and dietary intakes and eating behaviors to total water intake. The mean total water intake excluding plain water was 1071 g (398 g from beverages and 673 g from foods) and the estimated plain water intake was 1.3 L. Among Korean adults, 82% consumed beverages (excluding plain water) and these beverages contributed to 10% of daily energy intake and 32% of total water intake from beverages and foods. For every 100 kcal/day in energy intake, water intake consumed through beverages and foods increased by 18 g and 31 g, respectively. Water intake from beverages and foods was positively associated with energy from fat and dietary calcium, but inversely associated with energy density and energy from carbohydrates. When there was a 5% increase in energy intake from snacks and eating outside the home, there was an increase in water intake from beverages of 13 g and 2 g, respectively. Increased daily energy intake, the number of eating episodes, and energy intake from snacks and eating outside the home predicted higher water intake from beverages and foods. Our results provide evidence suggesting that various factors, including sociodemographic status, dietary intakes, and eating behaviors, could be important contributors to the water intake of Korean adults. Findings

  19. New energy visions for the Town of Ichinohe district; Ichinohecho chiiki shin energy vision

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-02-01

    The new energy visions are drawn for Town of Ichinohe, Iwate Pref. The town's population has been generally decreasing since 1975, from 21,433 to 17,906 in 1995. The town consumed energy totaling 288,691Gcal in 1998, of which the transportation sector accounts for 55%, followed by the domestic, commercial and industrial sectors, in this order, the industrial sector accounting for only 7%. The estimated new energy sources available to the town are wind power, power generated by temperature difference at rivers or using snow, solar energy, biomass energy and energy from wastes, in the order of quantity, totaling 137GWh/y as electrical power and 45.6Tcal/y as heat. The priority projects include making Ichinohe Primary School an eco-school, construction of a biomass demonstration plant in the Okunakayama district, introduction of a boiler firing wood chips at Okunakayama Heights, construction of a wind power mill at Takamori Heights, and introduction of new energies by the citizens. (NEDO)

  20. New energy visions for the Town of Ichinohe district; Ichinohecho chiiki shin energy vision

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-02-01

    The new energy visions are drawn for Town of Ichinohe, Iwate Pref. The town's population has been generally decreasing since 1975, from 21,433 to 17,906 in 1995. The town consumed energy totaling 288,691Gcal in 1998, of which the transportation sector accounts for 55%, followed by the domestic, commercial and industrial sectors, in this order, the industrial sector accounting for only 7%. The estimated new energy sources available to the town are wind power, power generated by temperature difference at rivers or using snow, solar energy, biomass energy and energy from wastes, in the order of quantity, totaling 137GWh/y as electrical power and 45.6Tcal/y as heat. The priority projects include making Ichinohe Primary School an eco-school, construction of a biomass demonstration plant in the Okunakayama district, introduction of a boiler firing wood chips at Okunakayama Heights, construction of a wind power mill at Takamori Heights, and introduction of new energies by the citizens. (NEDO)

  1. Energy consumption projection of Nepal: An econometric approach

    DEFF Research Database (Denmark)

    Parajuli, Ranjan; Østergaard, Poul A.; Dalgaard, Tommy

    2014-01-01

    In energy dependent economies, energy consumption is often linked with the growth in Gross Domestic Product (GDP). Energy intensity, defined herewith, as the ratio of the total primary energy consumption (TPE) to the GDP, is a useful concept for understanding the relation between energy demand...... and economic development. The scope of this article is to assess the future primary energy consumption of Nepal, and the projection is carried out along with the formulation of simple linear logarithmic energy consumption models. This initiates with a hypothesis that energy consumption is dependent...... with the national macro-economic parameters. To test the hypothesis, nexus between energy consumption and possible determinant variables are examined. Status of energy consumption between the period of 1996 and 2009, and for the same period, growth of economic parameters are assessed. Three scenarios are developed...

  2. The most important structures utilizing primary and secondary hydroenergetic potential for electric energy production

    International Nuclear Information System (INIS)

    Zacharovsky, M.

    1997-01-01

    In this paper the construction, technological parameters and operation of Gabcikovo (primary hydro energy power) and Cierny Vah (secondary hydro energy power) are described. Construction of the hydroelectric power plant (HPP) Gabcikovo started in 1978 as a part of a system of hydro power projects Gabcikovo-Nagymaros. Basic technical data are: installed capacity 8 x 90 MW, production in an average aqueous year 2.650 GWh, number of hydroelectric generating sets (HGS) 8, turbine flow 8 x 413-636 m 3 /s, head 12.9-24 m.The Gabcikovo plant produced 9.163 GWh of electricity from the beginning of its operation till the end of 1966. The construction of the pumped storage plant (PSP) Cierny Vah started in 1976 and it was put into operation at the end of 1980. The main goal of the PSP Cierny Vah is to meet the control functions of an electrification system of the Slovak Republic, a substitute function in the cases of unexpected power outages and a planned electricity production from re-pumping. Technological parts are: six re-pumping vertical HGS in a three machine arrangement - a motor-generator, a turbine, a pump - are located in three double-blocks. Basic technical data: installed capacity 6 x 122.4 MW + 0.768 MW, yearly production 1,281 GWh, number of HGS 6, number of domestic hydroelectric generating sets 1, turbine flow 3 x 30 m / s, pump flow 6 x 22 m 3 /s, upper reservoir volume 3.7 mil. m 3 , max. head 434 m, peak time 5.71 hour, pumping time 7.78 hour, re-pumping cycle efficiency 74.36%. From putting the PSP into operation till the end of 1996, the HGS in operation 145,269 hours in total, including 53,332 hours in a turbine mode of operation, 70,293 hours in a pumping mode operation and 21,644 hours in a compensation mode operation. Whereas they supplied 5,346 GWh in the mains and the consumed 6,933 GWh of electricity for pumping. Hydroenergetic potential is a primary source of energy which is recyclable, i.e. unexhaustible and also ecologically the most tolerable

  3. Brazilian energy balance 2010 - year 2009

    International Nuclear Information System (INIS)

    2010-01-01

    The Brazilian energy balance - BEB - is divided into eight chapters and ten annexes, whose contents are as follow: chapter 1 - energy analysis and aggregated data - presents energy highlights per source in 2009 and analyses the evolution of the internal offer of energy and its relationship with economic growth in 2009; chapter 2 - energy supply and demand by source - has the accountancy, per primary and secondary energy sources, of the production, import, export, variation of stocks, losses, adjustments, disaggregated total per socioeconomic sector in the country; chapter 3 - energy consumption by sector - presents the final energy consumption classified by primary and secondary source for each sector of the economy; chapter 4 - energy imports and exports - presents the evolution of the data on the import and export of energy and the dependence on external energy; chapter 5 - balance of transformation centers - presents the energy balances for the energy transformation centers including their losses; chapter 6 - energy resources and reserves - has the basic concepts use in the survey of resources and reserves of primary energy sources, with the evolution of the data from 1974 to 2009, through graphs and tables; chapter 7 - energy and socioeconomics - contains a comparison of energy, economic and population parameters, specific consumption, energy intensities, average prices and spending on petroleum imports; Chapter 8 - state energy data - presents energy data for the states by Federal Unit, main energy source production, energy installations, reserves and hydraulic potential. (author)

  4. Brazilian energy balance 2009 - year 2008

    International Nuclear Information System (INIS)

    2009-01-01

    The Brazilian energy balance - BEB - is divided into eight chapters and ten annexes, whose contents are as follow: Chapter 1 - Energy Analysis and Aggregated Data - presents energy highlights per source in 2008 and analyses the evolution of the internal offer of energy and its relationship with economic growth in 2008; Chapter 2 - Energy Supply and Demand by Source - has the accountancy, per primary and secondary energy sources, of the production, import, export, variation of stocks, losses, adjustments, disaggregated total per socioeconomic sector in the country; Chapter 3 - Energy Consumption by Sector - presents the final energy consumption classified by primary and secondary source for each sector of the economy; Chapter 4 - Energy Imports and Exports - presents the evolution of the data on the import and export of energy and the dependence on external energy; Chapter 5 - Balance of Transformation Centers - presents the energy balances for the energy transformation centers including their losses; Chapter 6 - Energy Resources and Reserves - has the basic concepts use in the survey of resources and reserves of primary energy sources, with the evolution of the data from 1974 to 2008, through graphs and tables; Chapter 7 - Energy and Socioeconomics - contains a comparison of energy, economic and population parameters, specific consumption, energy intensities, average prices and spending on petroleum imports; Chapter 8 - State Energy Data - presents energy data for the states by Federal Unit, main energy source production, energy installations, reserves and hydraulic potential. (author)

  5. Primary energy savings in desiccant and evaporative cooling-assisted 100% outdoor air system combined with a fuel cell

    International Nuclear Information System (INIS)

    Kim, Min-Hwi; Dong, Hae-Won; Park, Joon-Young; Jeong, Jae-Weon

    2016-01-01

    Highlights: • A LD-IDECOAS integrated with a PEMFC was proposed. • A pilot system was installed and tested during cooling operation. • The proposed system powered by the PEMFC saved 21% of the primary energy consumption during cooling. - Abstract: The main purpose of this study involved investigating the primary energy saving potential of a liquid desiccant and evaporative cooling-assisted 100% outdoor air system (LD-IDECOAS) integrated with a proton exchange membrane fuel cell (PEMFC). During the cooling season, the heat produced by the PEMFC was used to regenerate a weak desiccant solution, and the electricity generated was used to operate the LD-IDECOAS. A pilot LD-IDECOAS powered by a PEMFC was installed and operated in an office space to experimentally verify the annual operating energy savings of the proposed system. The findings indicated that the heat reclaimed from the PEMFC saved 42% of the desiccant solution regenerating energy when compared to that in the case of a conventional gas-fired water heater. The results also suggested that the LD-IDECOAS combined with a PEMFC consumed 21% less primary energy when compared with that of a system powered by grid electricity and a conventional gas-fired water heater.

  6. Total number albedo and average cosine of the polar angle of low-energy photons reflected from water

    Directory of Open Access Journals (Sweden)

    Marković Srpko

    2007-01-01

    Full Text Available The total number albedo and average cosine of the polar angle for water and initial photon energy range from 20 keV to 100 keV are presented in this pa per. A water shield in the form of a thick, homogenous plate and per pendicular incidence of the monoenergetic photon beam are assumed. The results were obtained through Monte Carlo simulations of photon reflection by means of the MCNP computer code. Calculated values for the total number albedo were compared with data previously published and good agreement was confirmed. The dependence of the average cosine of the polar angle on energy is studied in detail. It has been found that the total average cosine of the polar angle has values in the narrow interval of 0.66-0.67, approximately corresponding to the reflection angle of 48°, and that it does not depend on the initial photon energy.

  7. Total energy expenditure in burned children using the doubly labeled water technique

    International Nuclear Information System (INIS)

    Goran, M.I.; Peters, E.J.; Herndon, D.N.; Wolfe, R.R.

    1990-01-01

    Total energy expenditure (TEE) was measured in 15 burned children with the doubly labeled water technique. Application of the technique in burned children required evaluation of potential errors resulting from nutritional intake altering background enrichments during studies and from the high rate of water turnover relative to CO2 production. Five studies were discarded because of these potential problems. TEE was 1.33 +/- 0.27 times predicted basal energy expenditure (BEE), and in studies where resting energy expenditure (REE) was simultaneously measured, TEE was 1.18 +/- 0.17 times REE, which in turn was 1.16 +/- 0.10 times predicted BEE. TEE was significantly correlated with measured REE (r2 = 0.92) but not with predicted BEE. These studies substantiate the advantage of measuring REE to predict TEE in severely burned patients as opposed to relying on standardized equations. Therefore we recommend that optimal nutritional support will be achieved in convalescent burned children by multiplying REE by an activity factor of 1.2

  8. Strength functions of primary transitions following thermal neutron capture in strontium

    International Nuclear Information System (INIS)

    Winter, C.; Lieb, K.P.

    1989-01-01

    The primary E1, M1 and E2 γ-radiation in 87,88,89 Sr observed after thermal neutron capture was compared with the predictions of single particle and giant resonance models. The nuclei feature a wide range of neutron binding energies between 6.3 and 11.1 MeV, which makes a 5.5 MeV spectrum of primary transition energies available for investigation. The (n, γ) reaction was used to estimate the parameters of the spin-flip M1 giant resonance in strontium. The total energy weighted M1 strength of this resonance exceeds the results of shell model and random phase approximation calculations for 90 Zr by a factor of 3-4. The E1 strengths were found to agree with the established giant dipole resonance model. The few data on primary E2 transitions do not allow to differentiate between the giant quadrupole resonance and the single particle models. (orig.)

  9. Energy evaluation for the year 2006 in France

    International Nuclear Information System (INIS)

    2007-01-01

    This analysis of the energy french situation in 2006 presents the economical and energy context in the world and in France, the total primary energy consumption, the national production and the energy independence, the energy consumption for each energy type, the final energy consumption by sector, the energy intensity and the CO 2 emissions resulting from the energy combustion. It appears that the final consumption increases lightly (0,6%) but with a sensitive decrease of the CO 2 emissions from energy (-1,4%). (A.L.B.)

  10. Total Factor Productivity and Energy Intensity in Indian Manufacturing: A Cross-Sectional Study

    Directory of Open Access Journals (Sweden)

    Santosh Kumar Sahu

    2011-01-01

    Full Text Available The objective of the paper is to estimate the transcendental logarithmic production function and further study the determinants of total factor productivity (TFP of Indian manufacturing industries. The estimation of TFP is based on four inputs model, where apart from labour and capital, material and energy are the other two inputs. The findings of the paper suggest that labour and material inputs play major role as compared to the capital and energy input. Age of the firm, ownership, energy intensity, embodied and disembodied technology imports, research and development and exports were considered as the possible determinants of the TFP in the second stage regression. The finding of the estimates suggest that age of the firm, export intensity and disembodied technology import are positively related to the TFP, where ownership, energy intensity, embodied technology import and R&D intensity are negatively related to the TFP of the firms for Indian manufacturing.

  11. Higher energy efficiency in administrative and office buildings. Optimisation of primary energy consumption and economic efficiency; Energieeffiziente Buero- und Verwaltungsgebaeude. Hinweise zur primaerenergetischen und wirtschaftlichen Optimierung

    Energy Technology Data Exchange (ETDEWEB)

    Knissel, J.

    1999-12-15

    The study investigates measures to reduce primary energy consumption in administrative and office buildings and their effects in terms of economic efficiency. An exemplary office building is modernised step by step while recording the changes in the primary energy consumption coefficient. [German] In der vorliegenden Studie wird untersucht, wie weit und mit welchen Massnahmen der Primaerenergiebedarf von Buero- und Verwaltungsgebaeuden gesenkt werden kann und welche Auswirkungen dies auf die Wirtschaftlichkeit hat. Hierzu wird die energetische Ausfuehrungsqualitaet eines einfachen Beispielgebaeudes schrittweise verbessert und die Veraenderung des Primaerenergiekennwertes ermittelt. (orig.)

  12. Energy data book 2000; Memento sur l'energie 2000

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-07-01

    This memento about energy provides a series of tables with numerical data relative to energy resources and uses in France, in the European Union and in the rest of the world: energy consumption and demand (primary energy demand, consumption, and efficiency per region and per source; forecasting, CO{sub 2} emissions, energy independence, supplies, uses and imports, demand scenarios, energy savings..), power production (production per geopolitical region, in OECD countries and in France; peak load demand, power consumption and generation in France; hydro-power and thermal plants in France; total capacity, forecasts and exports), nuclear power (production, forecasting, reactors population, characteristics of French PWRs, uranium needs and fuel cycle), energy resources (renewable energies, fossil fuels and uranium reserves and production), economic data (gross national product, economic and energy indicators, prices and cost estimations), energy units and conversion factors (counting, calorific value of coals, production costs, energy units). (J.S.)

  13. Energy in Croatia, Annual Energy Report

    International Nuclear Information System (INIS)

    2001-12-01

    The review consists of the most recent and settled data for the year 2000 as well as data for the five-years period. In 2000 total energy consumption decreased by 2.8 percent compared to the previous year. As at the same time the gross domestic product increased by 3.7 percent, energy intensity grew, thus presenting a positive change of trend . The energy intensity, the measurement showing the total energy consumption per unit of gross domestic product, exceeded the level realised by the Western European countries, but was still more favourable than in most transition countries. At the same time 2000 saw an decrease of primary energy generation by 1.7 percent but, as a consequence of extremely favourable hydrological conditions, with a decreased production of natural gas and oil. The supply from own sources remained 51 percent but the trend is expected to be negative in the following few years bearing in mind the condition of the gas and oil reserves, i.e. cessation of coal production in Istria. Only partly will the process be slowed down by the production of natural gas from the Northern Adriatic. Natural gas production grew by 6.8 percent compared to the previous year, causing the share of natural gas in energy production to exceed 32 percent. In 2000 the transformation losses fell by 11 percent, transportation and distribution losses fell by 6.7 percent and non-energy consumption by 2.4 percent, while energy sector own use rose by 1.4 percent.. The result of this was that, despite the increase of total energy production by 2.8 percent, final energy demand fell by only 0.2 percent, i.e. 1.5 percent in other sectors and transport, and 2.9 percent increase in industry. Apart from these data, the publication includes all other relevant indicators about our energy system, i.e. system capacities, energy source prices, environmental influence, etc

  14. The Impact of Environmental Regulation on Total Factor Energy Efficiency: A Cross-Region Analysis in China

    Directory of Open Access Journals (Sweden)

    Jianting Lin

    2017-10-01

    Full Text Available Environmental regulations are the key measure by which governments achieve sustainable environmental and economic development. This study aimed to determine the direct and indirect impacts of environmental regulations on total factor energy efficiency of regions in China. Since regions have different levels of economic development and resource endowment, we used the slacks-based measure (SBM-undesirable model to calculate total factor energy efficiency considering regional technology heterogeneity and examined the regional impacts of environmental regulation on this efficiency using the Tobit regression model. A positive direct impact was generated in the eastern region of China by the forced mechanism, which forced enterprises to reduce fossil fuel energy demand and increase clean energy consumption; whereas a negative direct impact was generated in the middle and western regions owing to the green paradox, which is the observation that expected stringent environmental regulation prompts energy owners to accelerate resource extraction. Moreover, indirect impacts through technological progress and foreign direct investment were taken into account in the model, and the results show that the indirect impacts vary across regions. A logical response to these findings would be to develop different policies for different regions.

  15. Is the primary energy spectrum around the knee a statistical game?

    International Nuclear Information System (INIS)

    Kempa, J.

    2001-01-01

    The present state of research of the shape of the energy spectrum of primary cosmic ray nuclei and the chemical composition in the region of the so-called, knee, and beyond is highly unsatisfactory. It was not very successful when using extensive air showers. In the present paper an attempt is made to explain what is the cause of such a situation. The experimental results as to which there is no doubt that they were wrongly interpreted, will be indicated

  16. The energy and greenhouse-gas implications of internet video streaming in the United States

    International Nuclear Information System (INIS)

    Shehabi, Arman; Walker, Ben; Masanet, Eric

    2014-01-01

    The rapid growth of streaming video entertainment has recently received attention as a possibly less energy intensive alternative to the manufacturing and transportation of digital video discs (DVDs). This study utilizes a life-cycle assessment approach to estimate the primary energy use and greenhouse-gas emissions associated with video viewing through both traditional DVD methods and online video streaming. Base-case estimates for 2011 video viewing energy and CO 2 (e) emission intensities indicate video streaming can be more efficient than DVDs, depending on DVD viewing method. Video streaming benefits from relatively more efficient end-user devices than DVD viewing, though much of that savings is lost when accounting for the additional energy from network data transmission. Video streaming appears distinctly favorable when compared against any DVD viewing that includes consumer driving, which significantly increases the energy and CO 2 (e) emissions per viewing hour. Total US 2011 video viewing required about 192 PJ of primary energy and emitted about 10.5 billion kg of CO 2 (e). Shifting all 2011 DVD viewing to video streaming reduces the total primary energy use to about 162 PJ and the CO 2 (e) emissions to about 8.6 billion kg, representing a savings equivalent to the primary energy used to meet the electricity demand of nearly 200 000 US households each year. Sensitivity analysis indicates that results are most influenced by the end-user DVD player power demand, data transmission energy, and consumer travel for store DVDs. Data center energy use—both operational and embodied within the IT equipment—account for <1% of the total video streaming energy use. Results from this study indicate that designers and policy makers should focus on the efficiency of end-user devices and network transmission energy to curb future increases in energy use from the proliferation of video streaming. (letters)

  17. Energy storage in ceramic dielectrics

    International Nuclear Information System (INIS)

    Love, G.R.

    1990-01-01

    Historically, multilayer ceramic capacitors (MLC's) have not been considered for energy storage applications for two primary reasons. First, physically large ceramic capacitors were very expensive and, second, total energy density obtainable was not nearly so high as in electrolytic capacitor types. More recently, the fabrication technology for MLC's has improved significantly, permitting both significantly higher energy density and significantly lower costs. Simultaneously, in many applications, total energy storage has become smaller, and the secondary requirements of very low effective series resistance and effective series inductance (which, together, determine how efficiently the energy may be stored and recovered) have become more important. It is therefore desirable to reexamine energy storage in ceramics for contemporary commercial and near-commercial dielectrics. Stored energy is proportional to voltage squared only in the case of paraelectric insulators, because only they have capacitance that is independent of bias voltage. High dielectric constant materials, however, are ferroics (that is ferroelectric and/or antiferroelectric) and display significant variation of effective dielectric constant with bias voltage

  18. A multi-objective approach for optimal prioritization of energy efficiency measures in buildings: Model, software and case studies

    International Nuclear Information System (INIS)

    Karmellos, M.; Kiprakis, A.; Mavrotas, G.

    2015-01-01

    Highlights: • We provide a model for prioritization of energy efficiency measures in buildings. • We examine the case of a new building and one under renovation. • Objective functions are total primary energy consumption and total investment cost. • We provide a software tool that solves this multi-objective optimization problem. • Primary energy consumption and investment cost are inversely proportional. - Abstract: Buildings are responsible for some 40% of the total final energy consumption in the European Union and about 40% of the world’s primary energy consumption. Hence, the reduction of primary energy consumption is important for the overall energy chain. The scope of the current work is to assess the energy efficiency measures in the residential and small commercial sector and to develop a methodology and a software tool for their optimal prioritization. The criteria used for the prioritization of energy efficiency measures in this article are the primary energy consumption and the initial investment cost. The developed methodology used is generic and could be implemented in the case of a new building or retrofitting an existing building. A multi-objective mixed-integer non-linear problem (MINLP) needs to be solved and the weighted sum method is used. Moreover, the novelty of this work is that a software tool has been developed using ‘Matlab®’ which is generic, very simple and time efficient and can be used by a Decision Maker (DM). Two case studies have been developed, one for a new building and one for retrofitting an existing one, in two cities with different climate characteristics. The building was placed in Edinburgh in the UK and Athens in Greece and the analysis showed that the primary energy consumption and the initial investment cost are inversely proportional

  19. Energy policy, the energy price fallacy and the role of nuclear energy in the UK

    International Nuclear Information System (INIS)

    Brookes, L.G.

    1978-01-01

    The widely held belief that the world energy problem will be solved by rising prices - closing the energy gap by reducing demand and bringing in new, large, previously overcostly energy sources is rejected by the author who feels that high prices are the problem and not the solution. It is argued that supply and demand will be brought into balance at some price, and the objective of energy policy should be to make it as low as possible, by concentrating on the exploitation of large, low-cost energy sources. The role of nuclear energy in this discussion is considered with respect to three specific points: the currently identified reserves of low-cost uranium, if used in fast reactors, represent an energy source greater than all other energy sources put together; nuclear power is the cheapest, safest and cleanest way of producing electricity; and electricity production accounts for a very large part of total primary energy consumption. (U.K.)

  20. Hubbard-U corrected Hamiltonians for non-self-consistent random-phase approximation total-energy calculations

    DEFF Research Database (Denmark)

    Patrick, Christopher; Thygesen, Kristian Sommer

    2016-01-01

    In non-self-consistent calculations of the total energy within the random-phase approximation (RPA) for electronic correlation, it is necessary to choose a single-particle Hamiltonian whose solutions are used to construct the electronic density and noninteracting response function. Here we...... investigate the effect of including a Hubbard-U term in this single-particle Hamiltonian, to better describe the on-site correlation of 3d electrons in the transitionmetal compounds ZnS, TiO2, and NiO.We find that the RPA lattice constants are essentially independent of U, despite large changes...... in the underlying electronic structure. We further demonstrate that the non-selfconsistent RPA total energies of these materials have minima at nonzero U. Our RPA calculations find the rutile phase of TiO2 to be more stable than anatase independent of U, a result which is consistent with experiments...

  1. Total Skin Electron Beam for Primary Cutaneous T-cell Lymphoma

    Energy Technology Data Exchange (ETDEWEB)

    Elsayad, Khaled; Kriz, Jan; Moustakis, Christos; Scobioala, Sergiu; Reinartz, Gabriele; Haverkamp, Uwe; Willich, Normann [Department of Radiation Oncology, University Hospital of Muenster, Muenster (Germany); Weishaupt, Carsten [Department of Dermatology, University Hospital of Muenster, Muenster (Germany); Stadler, Rudolf [Department of Dermatology, Johannes-Wesling-Klinikum Minden, Minden (Germany); Sunderkötter, Cord [Department of Dermatology, University Hospital of Muenster, Muenster (Germany); Eich, Hans Theodor, E-mail: Hans.Eich@ukmuenster.de [Department of Radiation Oncology, University Hospital of Muenster, Muenster (Germany)

    2015-12-01

    Purpose: Recent trials with low-dose total skin electron beam (TSEB) therapy demonstrated encouraging results for treating primary cutaneous T-cell lymphoma (PCTCL). In this study, we assessed the feasibility of different radiation doses and estimated survival rates of different pathologic entities and stages. Methods and Materials: We retrospectively identified 45 patients with PCTCL undergoing TSEB therapy between 2000 and 2015. Clinical characteristics, treatment outcomes, and toxicity were assessed. Results: A total of 49 courses of TSEB therapy were administered to the 45 patients. There were 26 pathologically confirmed cases of mycosis fungoides (MF) lymphoma, 10 cases of Sézary syndrome (SS), and 9 non-MF/SS PCTCL patients. In the MF patients, the overall response rate (ORR) was 92% (50% complete remission [CR]), 70% ORR in SS patients (50% CR), and 89% ORR in non-MF/SS patients (78% CR). The ORR for MF/SS patients treated with conventional dose (30-36 Gy) regimens was 92% (63% CR) and 75% (25% CR) for low-dose (<30-Gy) regimens (P=.09). In MF patients, the overall survival (OS) was 77 months with conventional dose regimens versus 14 months with low-dose regimens (P=.553). In SS patients, the median OS was 48 versus 16 months (P=.219), respectively. Median event-free survival (EFS) for MF in conventional dose patients versus low-dose patients was 15 versus 8 months, respectively (P=.264) and 19 versus 3 months for SS patients (P=.457). Low-dose regimens had shorter treatment time (P=.009) and lower grade 2 adverse events (P=.043). A second TSEB course was administered in 4 MF patients with 100% ORR. There is a possible prognostic impact of supplemental/boost radiation (P<.001); adjuvant treatment (P<.001) and radiation tolerability (P=.021) were detected. Conclusions: TSEB therapy is an efficacious treatment modality in the treatment of several forms of cutaneous T-cell lymphoma. There is a nonsignificant trend to higher and longer clinical benefit

  2. [Quality of Outcome after Primary Total Hip Replacement at a Maximum Care Hospital in Relation to Preoperative Influencing Factors].

    Science.gov (United States)

    Osmanski-Zenk, K; Steinig, N S; Glass, Ä; Mittelmeier, W; Bader, R

    2015-12-01

    As the need for joint replacements will continue to rise, the outcome of primary total hip replacement (THR) must be improved and stabilised at a high level. In this study, we investigated whether pre-operative risk factors, such as gender, age and body weight at the time of the surgery or a restricted physical status (ASA-Status > 2 or Kellgren and Lawrence grade > 2) have a negative influence on the post-operative results or on patient satisfaction. Retrospective data collection and a prospective interview were performed with 486 patients who underwent primary total hip replacement between January 2007 and December 2010 in our hospital. The patients' satisfaction and quality of life were surveyed with the WOMAC-Score, SF-36 and EuroQol-5. Differences between more than two independent spot tests were tested with the non-parametric Kruskal-Wallis test. Differences between two independent spot tests were tested with the non-parametric Mann-Whitney U test. The frequencies were reported and odds ratios calculated. The confidence interval was set at 95 %. The level of significance was p total score of the SF-36 was 66.9 points. The patients declared an average EuroQol Index of 0.81. Our data show that the patients' gender did not influence the duration of surgery or the scores. However, female patients tended to exhibit more postoperative complications. However, increased patient age at the time of surgery was associated with an increased OR for duration of surgery, length of stay and risk of complications. Patients who had a normal body weight at time of the surgery showed better peri- and post-operative results. We showed that the preoperative estimated Kellgren and Lawrence grade had a significant influence on the duration of surgery. The ASA classification influenced the duration of surgery as well the length of stay and the rate of complications. The quality of results after primary THR depends on preoperative factors. Existing comorbidities have a

  3. Elevated levels of numerous cytokines in drainage fluid after primary total hip arthroplasty.

    Science.gov (United States)

    van der Heide, Huub J L; van der Kraan, Peter M; Rijnberg, Willard J; Buma, Pieter; Schreurs, B Willem

    2010-12-01

    As cytokines are involved in wound healing and other inflammatory processes, it could be valuable to measure their levels at the operative site. This study was conducted to investigate whether different cytokines are measurable in drainage fluid and, when measurable, whether we can find a difference in cytokine levels between one and six hours postoperatively. Samples from the drainage system in 30 consecutive patients undergoing primary total hip replacement were collected at one and six hours after closure of the wound. Levels of several cytokines were measured in the drainage fluids. A significant elevation of almost all cytokines was observed between the sample after one hour and six hours postoperatively. We found a strong correlation between the different pro-inflammatory cytokines. The IL-6 to IL-10 ratio were also raised, showing a pro-inflammatory predominance. Levels were much higher than those previously shown in serum.

  4. Energy in Croatia, Annual Energy Report 1995 - 1999

    International Nuclear Information System (INIS)

    2000-12-01

    The review consists of the most recent and settled data for the year 1999 as well as for the preceding four years. In 1999 total energy consumption increased by 4.5 percent compared to the previous year. As at the same time the gross domestic product decreased by 0.3 percent, energy intensity grew, thus presenting negative trend. The energy intensity, the measurement showing the total energy consumption per unit of gross domestic product, exceeded the level realised by the Western European countries, but was still more favourable than in most transition countries. At the same time 1999 saw an increase of primary energy generation by 1.5 percent but, as a consequence of extremely favourable hydrological conditions, with a decreased production of natural gas and oil. This caused a drop of the supply from own sources to 50.4 percent, the lowest value so far. This trend is expected to continue in the following few years bearing in mind the condition of the gas and oil reserves, i.e. cessation of coal production in Istria. Only partly will the process be slowed down by the production of natural gas from the Northern Adriatic. In 1999 the transformation losses rose by 7.3 percent, energy sector own use by 4.5 percent and non-energy consumption by 14.2 percent. Transportation and distribution losses fell by 9.9 percent. The result of this was that, despite the increase of total energy production by 4.5 percent, final energy demand grew by only 3.4 percent: 7.5 percent in transport, 4.5 percent in other sectors, and a 4.4 percent decrease in industry. Apart from these data, the publication includes all other relevant indicators about our energy system, i.e. system capacities, energy source prices, environmental influence, etc

  5. Comparison of depression symptoms between primary depression and secondary-to-schizophrenia depression.

    Science.gov (United States)

    Rahim, Twana; Rashid, Roshe

    2017-11-01

    This study exclusively aimed to clinically assess which symptom pattern discriminates primary depression from depression-secondary to-schizophrenia. A total of 98 patients with primary depression and 71 patients with secondary-to-schizophrenia depression were assessed for identifying the clinical phenomena of depression. Diagnosis of schizophrenia was confirmed by Mini International Neuropsychiatric Interview. Each participant was, however, assessed by Patient Health Questionnaire-9 as well as Calgary Depression Scale for Schizophrenia (CDSS) for possible concurrent depressive symptoms. Depressed mood, loss of interest, reduced energy and pathological guilt were more common in primary depression, whereas sleep disturbance and guilty ideas of reference were more amounting towards the diagnosis of depression secondary-to-schizophrenia. It is clinically hard to differentiate primary from secondary-to-schizophrenia depression, especially in the absence of obvious psychotic symptoms. However, the classical symptoms of depression like subjective depressed mood, anhedonia, reduced energy and pathological guilt are more prominent in the primary depression.

  6. Electric vehicles, primary energy sources and CO2 emissions: Romanian case study

    International Nuclear Information System (INIS)

    Varga, Bogdan Ovidiu

    2013-01-01

    Starting on the 24th of April, 2011, the Romanian government offered to subsidize all potential buyers of electric vehicles, both private and corporate, offering 25% off of the retail price up to 5000 euros with no pollution tax. The Romanian government encourages all governmental institutions to consider buying electric vehicles when deciding to change their existing vehicles stock. This decision is strictly related to the Romanian government's approval of a long-term Energy Strategy, building on the National Energy Strategy for the Medium Term. The government's strategy emphasizes increasing energy efficiency and boosting renewable energy use. The first electric vehicles distributed in the Romanian market are the Citroen-C-Zero, the Mitsubishi i-MiEV, the Renault Kangoo Z.E. and the Renault Fluence Z.E. The energy consumption of these vehicles was analyzed, considering the CO 2 generation characteristics of a Romanian electric power plant. -- Highlights: ► Tax and governmental support for electrical vehicles in Romania. ► Evaluate the CO 2 pollution of the electrical vehicles in Romania's case. ► Comprehensive understanding of the influence of primary energy source over the pollution of an electrical vehicle. ► Approach to decrees the pollution of the electrical vehicles.

  7. Nuclear energy and the greenhouse problem

    International Nuclear Information System (INIS)

    Kemeny, L.G.

    2001-01-01

    Last November - almost in parallel with the Hague Meeting on Climate Change - more than 1,500 of the world's top nuclear scientists and energy technologists met in Washington DC, at the Joint Conference of the American Nuclear Society, the European Nuclear Society, the Nuclear Energy Institute and the International Nuclear Energy Academy. Unlike the United Nations follow up to the Kyoto protocol, which ended in disarray, a note of high optimism and informed realism pervaded the nuclear conference which, among its multiple streams of subject material and papers by international experts, carried the two main themes of Long Term Globally Sustainable Energy Options and Nuclear Energy and the Greenhouse Problem. This paper considers the immense contribution to Greenhouse gas emission minimisation made by nuclear energy in 1999. In that year the global electricity production by the world's 435 nuclear power stations was 2,398 TWh or 16% of total electricity generation or 5% of total primary energy production. The amount of avoided carbon dioxide emission because of the use of nuclear energy in 1999 was 2.4 billion tonnes. This is 10% of total emissions. Japan's 54 nuclear power stations alone save the equivalent of Australia's total Greenhouse emissions. The secret of this success is Australia's uranium fuel

  8. Integrated Autopilot/Autothrottle Based on a Total Energy Control Concept: Design and Evaluation of Additional Autopilot Modes

    Science.gov (United States)

    Bruce, Kevin R.

    1988-01-01

    An integrated autopilot/autothrottle system was designed using a total energy control design philosophy. This design ensures that the system can differentiate between maneuvers requiring a change in thrust to accomplish a net energy change, and those maneuvers which only require elevator control to redistribute energy. The system design, the development of the system, and a summary of simulation results are defined.

  9. On the dependence of quasipotential on the total energy of a two-particle system

    International Nuclear Information System (INIS)

    Kapshaj, V.N.; Savrin, V.I.

    1986-01-01

    For a system of two relativistic particles described in the framework of the Logunov-Tavkhelidze one-time approach the dependence is calculated of the one-boson exchange potential on the total energy of the system. It is shown that in spite of a nonlocal form of the quasipotential obtained, three-dimensional equations for the wave function are reduced to one-dimensional ones by means of partial expansion. Influence of the energy dependence of the quasipotential on its behaviour in the coordinate representation is discussed

  10. TOTAL EYELID RECONSTRUCTION IN A PRIMARY IMMUN O DEFICIENT WI TH G I A NT PYOGENIC GRANULOMA

    Directory of Open Access Journals (Sweden)

    Vijay Kumar

    2015-06-01

    Full Text Available Total upper and lower eyelid defect is usually secondary to the excision of malignant or benign tumours, trauma and burns. Reconstruction of this type of defect is important not only for the cosmetic result, but also for coverage of the cornea an d prevent injury to eyeball. Pyogenic granuloma is usually preceded by the history of trauma to the eyelid. But reports of giant pyogenic granuloma of both upper and lower eyelid are rare. We present here a ten year old boy diagnosed primary immune deficient with a large fungating mass over both upper and lower eyelid, which was excised and total upper and lower eyelid defect was reconstructed with paramedian forehead flap. Histopathology revealed pyogenic granuloma. Post operatively c hild had good lid movements.

  11. Phenomenon of energy concentration in high-energy family events of cosmic rays

    CERN Document Server

    Wang He; Dai Zhi Qiang; Xue Liang; Feng Cun Feng; Zhang Xue Yao; Li Jin; Zhang Nai Jian; He Mao; Wang Cheng Rui; Ren Jing Ru; Lu Sui Ling

    2002-01-01

    The phenomenon of energy concentration in high-energy family events of cosmic rays is studied by comparing the results of family events of total visible energies 100-400 TeV observed in the Kanbala emulsion chamber experiment with the Monte Carlo simulation data. The simulation is made by the program CORSIKA in which QGSJET is applied as the hadronic interaction model, and the chemical composition of primary cosmic rays is obtained from the rigidity-cut model and the extrapolation of new results of direct measurements. This shows that the whole distribution tendency of the rate of energy concentration of simulated family events is basically consistent with that of the experiment

  12. Energy and the need for nuclear power

    International Nuclear Information System (INIS)

    1982-11-01

    The subject is discussed under the headings: fuel and mankind (world population estimates); fuel supply and demand (world nuclear and total primary energy demand forecasts); oil dependence; oil, gas and coal (world oil production and consumption; world coal reserves); nuclear option (consumption of nuclear energy in Western Europe; nuclear plant worldwide at December 1981; uranium reserves 1981); renewable resources; price of energy; Britain's need for nuclear power. (U.K.)

  13. Total body retention of orally administered 47Ca in primary hyperparathyroidism

    International Nuclear Information System (INIS)

    Mallette, L.E.; Sode, J.E.; Marx, S.J.; Georges, L.P.; Aurbach, G.D.

    1975-01-01

    Using a whole-body radiation detector, the total-body retention of 47 Ca 7 days after oral administration of the isotope to patients with various disorders of calcium metabolism was measured. The percent retention of 47 Ca given with 90 mg of unlabeled (carrier) calcium varied with the calcium metabolic status as follows: normals (n = 14), 33--43 percent (mean 38); primary hyperparathyroidism (n = 28), 32--74 percent (mean 52); idiopathic hypercalciuria (n = 9), 34--49 percent (mean 42); and hypercalcemia of other etiology (n = 3), 23--26 percent (mean 25). Almost half (13/28) of those with hyperparathyroidism showed a retention above 55 percent, distinguishing them from subjects with idiopathic hypercalciuria. Retention of 47 Ca correlated poorly with clinical measures of severity of hyperparathyroidism. When isotope was diluted with a smaller amount of carrier calcium (20 mg), retention was increased in normals (n = 5) to 46--54 percent (mean 50) and in hyperparathyroidism (n = 5) to 64--87 percent (mean 73). After surgical cure of hyperparathyroidism retention of isotope returned toward normal in 5 of 7 subjects. Whole-body retention of orally administered 47 Ca may prove useful in detecting hyperparathyroidism in subjects with mild hypercalcemia or hypercalciuria. (U.S.)

  14. Measurements of high energy photons in Z-pinch experiments on primary test stand

    International Nuclear Information System (INIS)

    Si, Fenni; Zhang, Chuanfei; Xu, Rongkun; Yuan, Xi; Huang, Zhanchang; Xu, Zeping; Ye, Fan; Yang, Jianlun; Ning, Jiamin; Hu, Qingyuan; Zhu, Xuebin

    2015-01-01

    High energy photons are measured for the first time in wire-array Z-pinch experiments on the Primary Test Stand (PTS) which delivers a current up to 8 MA with a rise time of 70 ns. A special designed detecting system composed of three types of detectors is used to measure the average energy, intensity, and pulse waveform of high energy photons. Results from Pb-TLD (thermoluminescence dosimeter) detector indicate that the average energy is 480 keV (±15%). Pulse shape of high energy photons is measured by the photodiode detector consisted of scintillator coupled with a photodiode, and it is correlated with soft x-ray power by the same timing signal. Intensity is measured by both TLD and the photodiode detector, showing good accordance with each other, and it is 10 10 cm −2 (±20%) at 2 m in the horizontal direction. Measurement results show that high energy photons are mainly produced in pinch regions due to accelerated electrons. PTS itself also produces high energy photons due to power flow electrons, which is one order smaller in amplitude than those from pinch region

  15. The trends in total energy, macronutrients and sodium intake among Japanese: findings from the 1995-2016 National Health and Nutrition Survey.

    Science.gov (United States)

    Saito, Aki; Imai, Shino; Htun, Nay Chi; Okada, Emiko; Yoshita, Katsushi; Yoshiike, Nobuo; Takimoto, Hidemi

    2018-06-04

    Monitoring nutritional status of the population is essential in the development and evaluation of national or local health policies. In this study, we aimed to demonstrate analysis on the trends in dietary intake of energy and macronutrients, as well as Na, in Japanese population using the data of series of cross-sectional national surveys - the National Nutrition Survey (NNS) and the National Health Nutrition Survey (NHNS) - during the period from 1995 to 2016. The NNS and NHNS participants aged 20-79 years were included in the analysis. Dietary intake was estimated using 1-d household-based dietary record. The trend in total energy intake, energy intake from macronutrients (fat and protein), Na intake and energy-adjusted Na intake were analysed using regression models adjusted to 2010 age distribution and anthropometry status. A total of 94 270 men and 107 890 women were included the analysis. Total energy intake showed a decreasing trend in both men and women. Similarly, energy intake from protein decreased, but energy intake (%) from fat increased in both sexes. Energy-adjusted Na intake showed a decreasing trend in both men and women. This study identified the decrease in total energy intake and energy intake from protein, whereas there were inverse trends in energy intake from fat among Japanese adults. Continued monitoring of trends in dietary intake will be needed, and there should be efforts to increase the accuracy of current survey procedures.

  16. Scenarios for total utilisation of hydrogen as an energy carrier in the future Danish energy system. Final report; Scenarier for samlet udnyttelse af brint som energibaerer i Danmarks fremtidige energisystem. Slutrapport

    Energy Technology Data Exchange (ETDEWEB)

    Hauge Petersen, A; Engberg Pedersen, T; Joergensen, K [and others

    2001-04-01

    This is the final report from a project performed for the Danish Energy Agency under its Hydrogen Programme. The project, which within the project group goes by the abbreviated title 'Hydrogen as an energy carrier', constructs and analyses different total energy scenarios for introducing hydrogen as an energy carrier, as energy storage medium and as a fuel in the future Danish energy system. The primary aim of the project is to study ways of handling the large deficits and surpluses of electricity from wind energy expected in the future Danish energy system. System-wide aspects of the choice of hydrogen production technologies, distribution methods, infrastructure requirements and conversion technologies are studied. Particularly, the possibility of using in the future the existing Danish natural gas distribution grid for carrying hydrogen will be assessed. For the year 2030, two scenarios are constructed: One using hydrogen primarily in the transportation sector, the other using it as a storage option for the centralised power plants still in operation by this year. For the year 2050, where the existing fossil power plants are expected to have been phased out completely, the scenarios for two possible developments are investigated: Either, there is a complete decentralisation of the use of hydrogen, converting and storing electricity surpluses into hydrogen in individual buildings, for later use in vehicles or regeneration of power and heat. Or, some centralised infrastructure is retained, such as hydrogen cavern stores and a network of vehicle hydrogen filling stations. The analysis is used to identify the components in an implementation strategy, for the most interesting scenarios, including a time sequence of necessary decisions and technology readiness. The report is in Danish, because it is part of the dissemination effort of the Hydrogen Committee, directed at the Danish population in general and the Danish professional community in particular. (au)

  17. Scenarios for total utilisation of hydrogen as an energy carrier in the future Danish energy system. Final report; Scenarier for samlet udnyttelse af brint som energibaerer i Danmarks fremtidige energisystem. Slutrapport

    Energy Technology Data Exchange (ETDEWEB)

    Hauge Petersen, A.; Engberg Pedersen, T.; Joergensen, K. (and others)

    2001-04-01

    This is the final report from a project performed for the Danish Energy Agency under its Hydrogen Programme. The project, which within the project group goes by the abbreviated title 'Hydrogen as an energy carrier', constructs and analyses different total energy scenarios for introducing hydrogen as an energy carrier, as energy storage medium and as a fuel in the future Danish energy system. The primary aim of the project is to study ways of handling the large deficits and surpluses of electricity from wind energy expected in the future Danish energy system. System-wide aspects of the choice of hydrogen production technologies, distribution methods, infrastructure requirements and conversion technologies are studied. Particularly, the possibility of using in the future the existing Danish natural gas distribution grid for carrying hydrogen will be assessed. For the year 2030, two scenarios are constructed: One using hydrogen primarily in the transportation sector, the other using it as a storage option for the centralised power plants still in operation by this year. For the year 2050, where the existing fossil power plants are expected to have been phased out completely, the scenarios for two possible developments are investigated: Either, there is a complete decentralisation of the use of hydrogen, converting and storing electricity surpluses into hydrogen in individual buildings, for later use in vehicles or regeneration of power and heat. Or, some centralised infrastructure is retained, such as hydrogen cavern stores and a network of vehicle hydrogen filling stations. The analysis is used to identify the components in an implementation strategy, for the most interesting scenarios, including a time sequence of necessary decisions and technology readiness. The report is in Danish, because it is part of the dissemination effort of the Hydrogen Committee, directed at the Danish population in general and the Danish professional community in particular. (au)

  18. Comparison of mode of failure between primary and revision total knee arthroplasties.

    Science.gov (United States)

    Liang, H; Bae, J K; Park, C H; Kim, K I; Bae, D K; Song, S J

    2018-04-01

    Cognizance of common reasons for failure in primary and revision TKA, together with their time course, facilitates prevention. However, there have been few reports specifically comparing modes of failure for primary vs. revision TKA using a single prosthesis. The goal of the study was to compare the survival rates, modes of failure, and time periods associated with each mode of failure, of primary vs. revision TKA. The survival rates, modes of failure, time period for each mode of failure, and risk factors would differ between primary and revision TKA. Data from a consecutive cohort comprising 1606 knees (1174 patients) of primary TKA patients, and 258 knees (224 patients) of revision TKA patients, in all of whom surgery involved a P.F.C ® prosthesis (Depuy, Johnson & Johnson, Warsaw, IN), was retrospectively reviewed. The mean follow-up periods of primary and revision TKAs were 9.2 and 9.8 years, respectively. The average 10- and 15-year survival rates for primary TKA were 96.7% (CI 95%,±0.7%) and 85.4% (CI 95%,±2.0%), and for revision TKA 91.4% (CI 95%,±2.5%) and 80.5% (CI 95%,±4.5%). Common modes of failure included polyethylene wear, loosening, and infection. The most common mode of failure was polyethylene wear in primary TKA, and infection in revision TKA. The mean periods (i.e., latencies) of polyethylene wear and loosening did not differ between primary and revision TKAs, but the mean period of infection was significantly longer for revision TKA (1.2 vs. 4.8 years, P=0.003). Survival rates decreased with time, particularly more than 10 years post-surgery, for both primary and revision TKAs. Continuous efforts are required to prevent and detect the various modes of failure during long-term follow-up. Greater attention is necessary to detect late infection-induced failure following revision TKA. Case-control study, Level III. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  19. Report on the analytical survey of the Pacific energy information; Taiheiyo energy joho bunseki chosa hokokusho

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-03-01

    Arrangement, investigation and analysis of an energy information exchange system were conducted, with the aim of coping with the development in the whole Asia/Pacific area, the stabilization of energy supply/demand, and the environmental problem and of realizing effective cooperation of every country in the area. Concerning the trend of the domestic primary energy supply/demand, there are some patterns. Countries which show high growth rates are developing countries such as Thailand and China, and NIES such as Korea and Taiwan. Countries where growth rates are slowing down and lowering are developed countries such as Australia, Canada, Japan and the U.S. Countries where energy supply/demand is not stabilized are Singapore, Hong Kong, Indonesia and Chile which are suffering from variations in import/export. The ultimate energy consumption is the domestic primary energy supply from which the conversion loss in the conversion sector was deducted, and indicates almost the same trend as the primary energy supply. It is divided into a stabilized type of developed countries and a rapidly increasing type and a stagnant type. However, there are some exceptions. Total data in the quarter of the year cannot be the yearly data by itself, but requires a year-end tax arrangement. 40 tabs.

  20. Energy from waste. Potentials and possibilities for usage; Energie aus Abfall. Potenziale und Nutzungsmoeglichkeiten

    Energy Technology Data Exchange (ETDEWEB)

    Wallmann, Rainer; Fritz, Thomas [Hochschule fuer Angewandte Wissenschaft und Kunst (HAWK), Goettingen (DE). Fachgebiet Nachhaltige Energie- und Umwelttechnik (NEUTec); Fricke, Klaus [Technische Univ. Braunschweig (Germany). Abt. Abfall- und Ressourcenwirtschaft

    2009-05-15

    In the present article the results of appraisal for the determination of the theoretical potential of energy and the current secondary energy supply of waste streams, which are relevant for the power production in Germany are represented. To sum up, the following conclusions arise from the balance: The theoretical primary energy supply potential of the examined waste streams amounts from 540 to 650 PJ/a and corresponds from 3.9 to 4.6% of the total primary energy consumption in Germany. In consideration of the system-dependent efficiencies and steering of flow patterns for materials altogether approx. 53 PJ electricity and 104 PJ (used) heat were produced as secondary energy within the regarded ranges in the year 2006 in Germany. This corresponds approx. to 1.7% of the final energy consumption in Germany. The outcome of the evaluated energy data for 2006 is a middle energy efficiency of approx. 26.5% (approx. 8.9% electrically and approx. 17.6% thermally). Under technically optimized conditions the power efficiency can be raised possibly on approx. 37%, whereby the share of the final energy consumption in Germany would increase to 2,3%. (orig.)

  1. Satisfactory Results of the Exeter Revision Femoral Stem Used for Primary Total Hip Arthroplasty.

    Science.gov (United States)

    Desy, Nicholas M; Johnson, Joshua D; Sierra, Rafael J

    2017-02-01

    The Exeter cemented femoral stem has demonstrated excellent clinical and radiographic outcomes as well as long-term survivorship free from aseptic loosening. A shorter revision stem (125 mm) with a 44 offset became available for the purpose of cement-in-cement revision situations. In certain cases, this shorter revision stem may be used for various primary total hip arthroplasties (THAs) where the standard length stem would require distally reaming the femoral canal. We sought to report on the early to midterm results of this specific stem when used for primary THA regarding (1) clinical and radiographic outcomes, (2) complications, and (3) survivorship. Twenty-nine patients (33 hips) underwent a hybrid THA using the smaller revision Exeter cemented femoral stem. Twenty-five patients (28 hips) had at least 2 years of follow-up and were assessed for clinical and radiographic outcomes. All 33 hips were included in the analysis of complications and survivorship. The Kaplan-Meier survivorship was performed using revision for all causes and for aseptic loosening as the end points. The average clinical follow-up was 4 years (range, 2-7). Harris Hip Scores improved from a mean preoperative value of 56 (range, 23-96) to 90 (range, 51-100) at the latest follow-up. All patients demonstrated superior cement mantles with no signs of loosening. One patient suffered a B2 periprosthetic fracture and 1 patient experienced 2 episodes of instability. The 5-year Kaplan-Meier survivorship was 96.7% for all causes of revision and was 100% using aseptic loosening as the end point. The shorter Exeter revision cemented femoral stem has favorable early to midterm clinical and radiographic outcomes when used for primary THA with a low complication rate and is a viable option in patients with narrow femoral canals where uncemented stem fixation is not desired. Copyright © 2016 Elsevier Inc. All rights reserved.

  2. Total-energy Assisted Tight-binding Method Based on Local Density Approximation of Density Functional Theory

    Science.gov (United States)

    Fujiwara, Takeo; Nishino, Shinya; Yamamoto, Susumu; Suzuki, Takashi; Ikeda, Minoru; Ohtani, Yasuaki

    2018-06-01

    A novel tight-binding method is developed, based on the extended Hückel approximation and charge self-consistency, with referring the band structure and the total energy of the local density approximation of the density functional theory. The parameters are so adjusted by computer that the result reproduces the band structure and the total energy, and the algorithm for determining parameters is established. The set of determined parameters is applicable to a variety of crystalline compounds and change of lattice constants, and, in other words, it is transferable. Examples are demonstrated for Si crystals of several crystalline structures varying lattice constants. Since the set of parameters is transferable, the present tight-binding method may be applicable also to molecular dynamics simulations of large-scale systems and long-time dynamical processes.

  3. Relativistic analysis of the dielectric Einstein box: Abraham, Minkowski and total energy-momentum tensors

    International Nuclear Information System (INIS)

    Ramos, Tomas; Rubilar, Guillermo F.; Obukhov, Yuri N.

    2011-01-01

    Highlights: → The definition of the momentum of light inside matter is studied. → Fully relativistic analysis of the dielectric 'Einstein box' thought experiment. → Minkowski, Abraham and the total energy-momentum tensors are derived in detail. → Some assumptions hidden in the usual Einstein box argument are identified. → The Abraham momentum is not uniquely selected as the momentum of light in this case. - Abstract: We analyse the 'Einstein box' thought experiment and the definition of the momentum of light inside matter. We stress the importance of the total energy-momentum tensor of the closed system (electromagnetic field plus material medium) and derive in detail the relativistic expressions for the Abraham and Minkowski momenta, together with the corresponding balance equations for an isotropic and homogeneous medium. We identify some assumptions hidden in the Einstein box argument, which make it weaker than it is usually recognized. In particular, we show that the Abraham momentum is not uniquely selected as the momentum of light in this case.

  4. Measurements of Daily Energy Intake and Total Energy Expenditure in People with Dementia in Care Homes: The Use of Wearable Technology.

    Science.gov (United States)

    Murphy, J; Holmes, J; Brooks, C

    2017-01-01

    To estimate daily total energy expenditure (TEE) using a physical activity monitor, combined with dietary assessment of energy intake to assess the relationship between daily energy expenditure and patterns of activity with energy intake in people with dementia living in care homes. A cross-sectional study in care homes in the UK. Twenty residents with confirmed dementia diagnosis were recruited from two care homes that specialised in dementia care. A physical activity monitor (SensewearTM Armband, Body Media, Pittsburgh, PA) was employed to objectively determine total energy expenditure, sleep duration and physical activity. The armband was placed around the left upper triceps for up to 7 days. Energy intake was determined by weighing all food and drink items over 4 days (3 weekdays and 1 weekend day) including measurements of food wastage. The mean age was 78.7 (SD ± 11.8) years, Body Mass Index (BMI) 23.0 (SD ± 4.2) kg/m2; 50% were women. Energy intake (mean 7.4; SD ± 2.6) MJ/d) was correlated with TEE (mean 7.6; SD ± 1.8 MJ/d; r=0.49, p<0.05). Duration of sleeping ranged from 0.4-12.5 (mean 6.1) hrs/d and time spent lying down was 1.3-16.0 (8.3) hrs/d. On average residents spent 17.9 (6.3-23.4) hrs/d undertaking sedentary activity. TEE was correlated with BMI (r=0.52, p<0.05) and body weight (r=0.81, p<0.001) but inversely related to sleep duration (r=-0.59, p<0.01) and time lying down (r=-0.62, p<0.01). Multiple linear regression analysis revealed that after taking BMI, sleep duration and time spent lying down into account, TEE was no longer correlated with energy intake. The results show the extent to which body mass, variable activity and sleep patterns may be contributing to TEE and together with reduced energy intake, energy requirements were not satisfied. Thus wearable technology has the potential to offer real-time monitoring to provide appropriate nutrition management that is more person-centred to prevent weight loss in dementia.

  5. Energy handbook. 2008 edition; Memento sur l'energie. Edition 2008

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2008-07-01

    This memento about energy provides a series of tables with numerical data relative to energy resources and uses in France, in the European Union and in the rest of the world: energy consumption and demand (primary energy demand, consumption, and efficiency per region and per source. Forecasting, CO{sub 2} emissions, energy independence, supplies, uses and imports, demand scenarios, energy savings..), power production (production per geopolitical region, in OECD countries and in France. Peak load demand, power consumption and generation in France. Hydro-power and thermal plants in France. Total capacity, forecasts and exports), nuclear power (production, forecasting, reactors population, characteristics of French PWRs, uranium needs and fuel cycle), energy resources (renewable energies, fossil fuels and uranium reserves and production), economic data (gross national product, economic and energy indicators, prices and cost estimations), energy units and conversion factors (counting, calorific value of coals, production costs, energy units). (A.L.B.)

  6. TX 2000: total reflection and 45o energy dispersive x-ray fluorescence spectrometer

    International Nuclear Information System (INIS)

    Pasti, F.; Torboli, A.; Valdes, M.

    2000-01-01

    This equipment, developed by Ital Structures, combines two kinds of energy dispersive X-ray fluorescence techniques, the first using total reflection geometry and the second conventional 45 o geometry. The equipment is completely controlled by a PC and to reach the condition of total reflection is very easy because it is enough to load the file with the right position for the corresponding energy. In this apparatus we used an x-ray tube with an alloy anode of Mo/W with a long fine focus at 2200 W. To monochromatize the x-ray beam while choosing, for example, the Mo K alpha or W L alpha or a piece of white spectrum of 33 keV, we use a highly reflective multilayer made of Si/W with 2d = 45.5 A o . The detector used in the equipment is a lithium drifted silicon detector (Si(Li)) with an excellent energy resolution of 135 eV at 5.9 keV and 1000 cps. We developed two programs written in Windows 95, 98 and NT for a 32 bit microprocessor. The first one is called TYACQ32 and has the following functions: first, complete control of the hardware, second automatic alignment of the TX 2000 spectrometer and third acquisition of spectra. The second program is EDXRF32. This is a program to accomplish spectrum and quantitative analysis for TXRF and EDXRF 45 o degrees analysis. (author)

  7. Annual Energy Review 2007

    Energy Technology Data Exchange (ETDEWEB)

    Seiferlein, Katherine E. [USDOE Energy Information Administration (EIA), Washington, DC (United States)

    2008-06-01

    The Annual Energy Review (AER) is the Energy Information Administration's (EIA) primary report of annual historical energy statistics. For many series, data begin with the year 1949. Included are data on total energy production, consumption, and trade; overviews of petroleum, natural gas, coal, electricity, nuclear energy, renewable energy, international energy, as well as financial and environment indicators; and data unit conversion tables. Publication of this report is required under Public Law 95–91 (Department of Energy Organization Act), Section 205(c), and is in keeping with responsibilities given to the EIA under Section 205(a)(2), which states: “The Administrator shall be responsible for carrying out a central, comprehensive, and unified energy data and information program which will collect, evaluate, assemble, analyze, and disseminate data and information....”

  8. Mortality After Total Knee and Total Hip Arthroplasty in a Large Integrated Health Care System.

    Science.gov (United States)

    Inacio, Maria C S; Dillon, Mark T; Miric, Alex; Navarro, Ronald A; Paxton, Elizabeth W

    2017-01-01

    The number of excess deaths associated with elective total joint arthroplasty in the US is not well understood. To evaluate one-year postoperative mortality among patients with elective primary and revision arthroplasty procedures of the hip and knee. A retrospective analysis was conducted of hip and knee arthroplasties performed in 2010. Procedure type, procedure volume, patient age and sex, and mortality were obtained from an institutional total joint replacement registry. An integrated health care system population was the sampling frame for the study subjects and was the reference group for the study. Standardized 1-year mortality ratios (SMRs) and 95% confidence intervals (CIs) were calculated. A total of 10,163 primary total knee arthroplasties (TKAs), 4963 primary total hip arthroplasties (THAs), 606 revision TKAs, and 496 revision THAs were evaluated. Patients undergoing primary THA (SMR = 0.6, 95% CI = 0.4-0.7) and TKA (SMR = 0.4, 95% CI = 0.3-0.5) had lower odds of mortality than expected. Patients with revision TKA had higher-than-expected mortality odds (SMR = 1.8, 95% CI = 1.1-2.5), whereas patients with revision THA (SMR = 0.9, 95% CI = 0.4-1.5) did not have higher-than-expected odds of mortality. Understanding excess mortality after joint surgery allows clinicians to evaluate current practices and to determine whether certain groups are at higher-than-expected mortality risk after surgery.

  9. Variability in the reported energy, total fat and saturated fat contents in fast-food products across ten countries.

    Science.gov (United States)

    Ziauddeen, Nida; Fitt, Emily; Edney, Louise; Dunford, Elizabeth; Neal, Bruce; Jebb, Susan A

    2015-11-01

    Fast foods are often energy dense and offered in large serving sizes. Observational data have linked the consumption of fast foods to an increased risk of obesity and related diseases. We surveyed the reported energy, total fat and saturated fat contents, and serving sizes, of fast-food items from five major chains across ten countries, comparing product categories as well as specific food items available in most countries. MRC Human Nutrition Research, Cambridge, UK. Data for 2961 food and drink products were collected, with most from Canada (n 550) and fewest from the United Arab Emirates (n 106). There was considerable variability in energy and fat contents of fast foods across countries, reflecting both the portfolio of products and serving size variability. Differences in total energy between countries were particularly noted for chicken dishes (649-1197 kJ/100 g) and sandwiches (552-1050 kJ/100g). When comparing the same product between countries variations were consistently observed in total energy and fat contents (g/100 g); for example, extreme variation in McDonald's Chicken McNuggets with 12 g total fat/100 g in Germany compared with 21·1 g/100 g in New Zealand. These cross-country variations highlight the possibility for further product reformulation in many countries to reduce nutrients of concern and improve the nutritional profiles of fast-food products around the world. Standardisation of serving sizes towards the lower end of the range would also help to reduce the risk of overconsumption.

  10. Variability in the reported energy, total fat and saturated fat content in fast food products across ten countries

    Science.gov (United States)

    Ziauddeen, Nida; Fitt, Emily; Edney, Louise; Dunford, Elizabeth; Neal, Bruce; Jebb, Susan A.

    2016-01-01

    Objective Fast foods are often energy dense and offered in large serving sizes. Observational data has linked the consumption of fast food to an increased risk of obesity and related diseases. Design We surveyed the reported energy, total fat and saturated fat contents, and serving sizes, of fast food items from five major chains across 10 countries, comparing product categories as well as specific food items available in most countries. Setting MRC Human Nutrition Research (HNR), Cambridge Subjects Data for 2961 food and drink products were collected, with most from Canada (n=550) and fewest from United Arab Emirates (n=106). Results There was considerable variability in energy and fat content of fast food across countries, reflecting both the portfolio of products, and serving size variability. Differences in total energy between countries were particularly noted for chicken dishes (649-1197kJ/100g) and sandwiches (552-1050kJ/100g). When comparing the same product between countries variations were consistently observed in total energy and fat content (g/100g) with extreme variation in McDonald’s Chicken McNuggets with 12g total fat (g/100g) in Germany compared to 21.1g in New Zealand. Conclusions These cross-country variations highlight the possibility for further product reformulation in many countries to reduce nutrients of concern and improve the nutritional profiles of fast food products around the world. Standardisation of serving sizes towards the lower end of the range would also help to reduce the risk of overconsumption. PMID:25702788

  11. Washington State Energy Use Profile, 1960--1990

    International Nuclear Information System (INIS)

    Anderson, M.

    1992-07-01

    This report is divided into three sections, each with data on energy consumption, prices, and expenditures. The first section presents an overview of statewide energy use trends. The second section presents energy use trends in four basic consuming sectors: residential, commercial, industrial, and transportation. The third section presents energy use trends in specific resource markets: natural gas, petroleum, electricity, coal, and wood. The appendixes contain information about data, sources, and a glossary. Data about Washington's energy resources are reported in two forms: in measures common to the fuel (kWh, barrels, etc.) and in the generic measure British thermal units (Btu). The common measures allow the reader to quickly grasp information in a familiar form. The generic measure allows the reader to compare energy resources. Conversion to Btu occasionally produces counter-intuitive results. For example, in different years, petroleum products have different average energy values, resulting in different conversion factors from barrels to Btu. A large amount of data contained in the Profile has been categorized and presented in a variety of ways. Understanding the meaning of categories is critical to understanding differences between the tables, especially those tables that present similar data. For example, petroleum trends are not the same as transportation trends, though they are similar because transportation is almost entirely dependent on petroleum. In another example, total end-use fuel energy consumption is not the same as total primary energy consumption. End-use fuel consumption does not include energy used for the generation of electricity. Counting both fuel used for electricity generation and electricity itself could result in double counting. Primary fuel consumption, on the other hand, does include energy used for the generation of electricity and is greater than total end-use consumption

  12. National energy data profile, Austria 1992

    International Nuclear Information System (INIS)

    1993-12-01

    Detail information about the energy consumption, energy demand and supply, general features of energy economy and the analysis of the development of energy economy in Austria in 1992 as well as preliminary data on energy consumption in the first 6 months of 1993 is given. Statistical data about the development of energy demand by sectors, development of total final energy demand by energy carriers (articulated in coal, refined petroleum products, natural gas, other, electricity and heat), development of energy consumption in industry (articulated in coal, refined petroleum products, natural gas, other, electricity and heat) and development of energy consumption of domestic consumers (articulated in coal, refined petroleum products, natural gas, other, electricity and heat) is shown. Graphical data about (1) primary energy supply by source, (2) primary energy, economic activity and electricity, (3) indigenous energy production, (4) conventional energy resources, (5) electricity supply by source, (6) electricity consumption by sector is presented for the years 1970 - 1992. Data about the development and exploitable hydro-power potentials by rivers and the main sources of man-made emissions of air pollutants in Austria 1990 according to the results of the CORINE-inventory are added. (blahsl)

  13. Energy in Turkey

    International Nuclear Information System (INIS)

    Bumin, S.

    2005-01-01

    Because of its limited energy resources, Turkey is heavily dependent on imported oil and gas. 73 percent of the world's proven oil reserves and 72 percent of the world's proven gas reserves are located in the surrounding regions of Turkey: Middle East, Caspian Region and Russia. This makes Turkey a crucial bridge between energy rich regions and Europe. There are major oil and gas pipelines going through Turkey and additional pipelines are being constructed or are being planned. There is some production of lignite which is used in power plants and industry. Turkey's natural energy resources are quite diversified; with quite abundant coal reserves. Energy forecasts show that primary energy demand would be 117 million TOE in 2005 and 156 million TOE in 2010. Oil has the biggest share (39 percent) in total primary energy consumption, while natural gas has a share of 21 percent and increasing due to the recent diversification efforts of energy resources. Turkey has about 1percent of the total world hydroelectric potential and a considerable potential for electricity generation from wind. As of early 2004, Turkey had electric power generating capacity of around 32,000 megawatts (MW), and was building 13,000 MW more. Since adoption of Electricity Market Law in February 2001, there were significant changes towards liberalisation of power generation market and distribution in the country. Privatization of generation assets is envisaged to start in 2006. The Electricity Market Law set the stage for new supporting laws and regulations as well as new organization of the market: the Energy Market Regulation Agency (EMRA), that oversees the power, natural gas markets, oil markets and liquefied petroleum gases market, including setting tariffs, issuing licenses, and assuring competition; the Energy Market Regulatory Board, which runs the EMRA; the Energy Market Licensing Regulation and the Electricity Market Tariffs Regulation; 4-phase approach towards electric energy market

  14. Assessment of the status and outlook of biomass energy in Jordan

    International Nuclear Information System (INIS)

    Al-Hamamre, Zayed; Al-Mater, Ali; Sweis, Fawaz; Rawajfeh, Khaled

    2014-01-01

    Highlights: • The potential of utilizing biomass as an energy source in Jordan is investigated. • The biomass thermal energy represents 10.2% of the total primary energy. • Bioenergy production depends on biomass availability, conversion and recovery efficiency. - Abstract: This work investigates the status and potential of utilizing biomass as an energy source in Jordan. The amount of waste and residue is estimated to be 6.680 million tons for the year 2011. Two scenarios were investigated: biogas production and thermal treatment. The amount of biogas that can be produced from various biomass sources in Jordan is estimated at 428 MCM. The equivalent annual power production is estimated at 698.1 GW h. This is equivalent to about 5.09% of the consumed electricity (13,535 GW h) and 39.65% of the imported electricity in 2011. The alternative scenario of thermal treatment was investigated. The total theoretical thermal energy that can be obtained assuming 70% conversion efficiency is equivalent to 779 thousand toe (5.33 million barrels of crude oil) which amounts to 10.2% of the total primary energy consumed in 2011. Due to biomass collection and recovery challenges, the energy availability factor varies for the different resources. Hence, contribution of the different biomass resources can significantly vary

  15. Influence of primary fragment excitation energy and spin distributions on fission observables

    Science.gov (United States)

    Litaize, Olivier; Thulliez, Loïc; Serot, Olivier; Chebboubi, Abdelaziz; Tamagno, Pierre

    2018-03-01

    Fission observables in the case of 252Cf(sf) are investigated by exploring several models involved in the excitation energy sharing and spin-parity assignment between primary fission fragments. In a first step the parameters used in the FIFRELIN Monte Carlo code "reference route" are presented: two parameters for the mass dependent temperature ratio law and two constant spin cut-off parameters for light and heavy fragment groups respectively. These parameters determine the initial fragment entry zone in excitation energy and spin-parity (E*, Jπ). They are chosen to reproduce the light and heavy average prompt neutron multiplicities. When these target observables are achieved all other fission observables can be predicted. We show here the influence of input parameters on the saw-tooth curve and we discuss the influence of a mass and energy-dependent spin cut-off model on gamma-rays related fission observables. The part of the model involving level densities, neutron transmission coefficients or photon strength functions remains unchanged.

  16. Total energy supply for remote human habitations (Or 'Nuclear North of 60')

    International Nuclear Information System (INIS)

    Harris, J.

    2012-01-01

    This presentation will examine the direct application of nuclear energy solutions in the north, and remote areas of Canada. Further it will challenge the existing energy network based on the shipment of fossil fuels to remote areas, and examine the use of small, modular, and/or deployable nuclear plants in these communities. The use of these small reactors and some newly emerging technologies will likely provide a near total energy supply for these communities. In particular low grade heat processes, district heating, the 'local' production of motive fuels, and local food production will be examined. Additionally the economic and social impact of moving the value added side of many of these processes to the local communities will also be briefly discussed.

  17. Baryon number violation in high energy collisions

    International Nuclear Information System (INIS)

    Farrar, G.R.; Meng, R.

    1990-08-01

    We study the phenomenology of baryon number violation induced by electroweak instantons. We find that if the naive-instanton amplitudes were valid for arbitrarily high energies, the event rate at the SSC would be a few per hour, with a typical event consisting of 3 'primary' antileptons and 7 'primary' antiquark jets, accompanied by ≅ 85 electroweak gauge bosons, having a sharp threshold in the total sub-energy at about 17 TeV. We describe how to establish their electroweak-instanton-induced origin. The naive instanton approximation is known to overestimate the rate for these processes, so this work focusses attention on the need for more accurate calculations, and for a calculational method which is appropriate when the energy of the initial particles is above the sphaleron energy. (orig.)

  18. Fission-fragment angular distributions and total kinetic energies for 235U(n,f) from .18 to 8.83 MeV

    International Nuclear Information System (INIS)

    Meadows, J.W.; Budtz-Joergensen, C.

    1982-01-01

    A gridded ion chamber was used to measure the fission fragment angular distribution and total kinetic energy for the 235 U(n,f) reaction from 0.18 to 8.81 MeV neutron energy. The anisotropies are in generally good agreement with earlier measurements. The average total kinetic energy is approx. 0.2 MeV greater than the thermal value at neutron energies < 2 MeV and shows a sudden decrease of approx. 0.8 MeV between 4 and 5 MeV neutron energy, well below the (n, n'f) threshold. Possible causes of this decrease are a change in the mass distribution or decreased shell effects in the heavy fragment

  19. The logic of the primary energy prices evolution

    International Nuclear Information System (INIS)

    Giraud, P.N.

    1992-01-01

    This paper deals, very briefly, with the basis factors determining the prices levels of the primary energies and the logic of their evolution both in the short and in the long term. It first gives definitions: of the limits of mineral commodities prices fluctuations and of the long term equilibrium prices. Then, it tries to demonstrate three points: (1) Coal and nuclear electricity prices are driven in the long term only by their own production and environmental costs. Moreover, coal prices fluctuations are surrounded by factors which are basically independent from oil prices. (2) There is no such thing as one single equilibrium price for oil, but several ones, depending on political factors, and among them, on the degree of consensus between the 'Five' of the Gulf (Saudi Arabia, Iran, Irak, Koweit, The Emirates). (3) Natural gas prices are in an intermediate situation, but tend to get closer to the case of coal and nuclear prices. 4 figs

  20. [PERSONALIZED DISTAL FEMORAL VALGUS RESECTION ANGLE IN PRIMARY TOTAL KNEE ARTHROPLASTY].

    Science.gov (United States)

    Wang, Xilong; Shang, Xifu; Ll, Guoyuan; He, Rui; Zheng, Jie

    2015-01-01

    To investigate the feasibility and effectiveness of a personalized distal femoral valgus resection angle for improving postoperative coronal alignment of lower limb in total knee arthroplasty (TKA). A retrospective analysis was made on the clinical data of 50 patients who received primary TKA between January 2013 and February 2013. There were 11 male and 39 female patients with degenerative knee osteoarthritis. The patients were divided into 2 groups. In test group (n=25), the resection angle was adjusted to the femoral mechanical anatomical angle (FMA); in control group (n=25), a fixed distal valgus resection angle of 5° was used. There was no significant difference in gender, age, body mass index, disease duration, sides, grade, preoperative FMA, mechanical femorotibial angle (MFT), and preoperative Knee Society Score (KSS) between 2 groups (P > 0.05). Whole long X-ray film was taken to measure FMA and MFT at 3 days after operation, postoperative KSS was used to evaluate the knee function after 6 and 15 months. MFT was (-0.20 ± 1.87)° in test group and was (1.71 ± 3.67)° in control group, showing significant difference between 2 groups (t = 2.32, P = 0.02). The ideal MFT angle (0 ± 3)° was achieved in 22 patients (88%) of test group and in 16 patients (64%) of control group, showing significant difference between 2 groups (χ2 = 2.32, P = 0.02). Primary healing of incision was obtained in all patients of 2 groups. No deep venous thrombosis occurred. The patients of 2 groups were followed up 15 months after operation. There was significant difference in KSS between test and control groups at 6 months (88.23 ± 2.57 vs. 82.92 ± 2.59) (t = 7.26, P = 0.00) and at 15 months (90.76 ± 2.77 vs. 88.65 ± 1.77) (t = 3.20, P = 0.02). No sign of prosthesis loosening was observed by X-ray examination. Compared with using of a fixed distal femoral resection angle, an individual FMA can significantly improve the postoperative MFT and promote early recovery of the knee

  1. A composition dependent energy scale and the determination of the cosmic ray primary mass in the ankle region

    Science.gov (United States)

    Supanitsky, A. D.; Etchegoyen, A.; Melo, D.; Sanchez, F.

    2015-08-01

    At present there are still several open questions about the origin of the ultra high energy cosmic rays. However, great progress in this area has been made in recent years due to the data collected by the present generation of ground based detectors like the Pierre Auger Observatory and Telescope Array. In particular, it is believed that the study of the composition of the cosmic rays as a function of energy can play a fundamental role for the understanding of the origin of the cosmic rays. The observatories belonging to this generation are composed of arrays of surface detectors and fluorescence telescopes. The duty cycle of the fluorescence telescopes is ∼10% in contrast with the ∼100% of the surface detectors. Therefore, the energy calibration of the events observed by the surface detectors is performed by using a calibration curve obtained from a set of high quality events observed in coincidence by both types of detectors. The advantage of this method is that the reconstructed energy of the events observed by the surface detectors becomes almost independent of simulations of the showers because just a small part of the reconstructed energy (the missing energy), obtained from the fluorescence telescopes, comes from simulations. However, the calibration curve obtained in this way depends on the composition of the cosmic rays, which can introduce biases in composition analyses when parameters with a strong dependence on primary energy are considered. In this work we develop an analytical method to study these effects. We consider AMIGA (Auger Muons and Infill for the Ground Array), the low energy extension of the Pierre Auger Observatory corresponding to the surface detectors, to illustrate the use of the method. In particular, we study the biases introduced by an energy calibration dependent on composition on the determination of the mean value of the number of muons, at a given distance to the showers axis, which is one of the parameters most sensitive to

  2. Global energy perspective of Turkey

    International Nuclear Information System (INIS)

    Sen, H. Mete

    2006-01-01

    Global energy demand is growing rapidly at an average rate of 4% per year in parallel with the economy while EU-25 has only 0,8% during the last decade. Total primary energy supply is 87 818 000 toe of which 72% was imported; in comparison the average dependency rate is 49,5% in the EU. Such excessive dependency creates harmful effects on the national economy. Oil and natural gas imports bill was 19,5 billion US $ in 2005. Primary energy demand growth rate is twice as much of the production rate in the period 1980 2004. Fossil fuels accounts for 86% of Turkeys global energy supply in 2004. Population growth rate is one of the major parameters affecting the energy balance. Energy and electricity consumptions per capita are still one third of the EUs average.. Turkeys coal reserves needs to be utilized at higher rate and hydropower, wind power and geothermal energy potentials should be developed in order to decrease the imported energy dependence, soon. Due to the buy or pay bilateral agreements with suppliers, storage capabilities should be realized for excessive natural gas supply. Turkeys average growth rate of electricity production is 8,1% while installed capacity has 8,5% for the last 25 years. The present total installed capacity is 39 020 MW in which renewables has a share of 34%. Total electricity production was 162 TWh in 2005 of which 75,4% was supplied by thermal power plants. Share of natural gas is 44% of the annual electricity production. Considering the present power plants and the ones under construction, electricity supply and demand will be in balance till the year of 2010 (with high demand scenario) or 2015 (with low demand scenario). Nuclear power is being considered for electricity supply security after 2015. But, the general approach for supply security is first to develop the domestic coal reserves, renewable energy resources.

  3. The influence of x-ray energy on lung dose uniformity in total-body irradiation

    International Nuclear Information System (INIS)

    Ekstrand, Kenneth; Greven, Kathryn; Wu Qingrong

    1997-01-01

    Purpose: In this study we examine the influence of x-ray energy on the uniformity of the dose within the lung in total-body irradiation treatments in which partial transmission blocks are used to control the lung dose. Methods and Materials: A solid water phantom with a cork insert to simulate a lung was irradiated by x-rays with energies of either 6, 10, or 18 MV. The source to phantom distance was 3.9 meters. The cork insert was either 10 cm wide or 6 cm wide. Partial transmission blocks with transmission factors of 50% were placed anterior to the cork insert. The blocks were either 8 or 4 cm in width. Kodak XV-2 film was placed in the midline of the phantom to record the dose. Midplane dose profiles were measured with a densitometer. Results: For the 10 cm wide cork insert the uniformity of the dose over 80% of the block width varied from 6.6% for the 6 MV x-rays to 12.2% for the 18 MV x-rays. For the 6 cm wide cork insert the uniformity was comparable for all three x-ray energies, but for 18 MV the central dose increased by 9.4% compared to the 10 cm wide insert. Conclusion: Many factors must be considered in optimizing the dose for total-body irradiation. This study suggests that for AP/PA techniques lung dose uniformity is superior with 6 MV irradiation. The blanket recommendation that the highest x-ray energy be used in TBI is not valid for all situations

  4. The Status and Evolution of Energy Supply and Use in Mexico Prior to the 2014 Energy Reform: An Input-Output Approach †

    Directory of Open Access Journals (Sweden)

    Zeus Guevara

    2017-03-01

    Full Text Available In 2014, the Mexican government approved a bold energy reform that allows private energy companies to freely participate in the energy market (something prohibited during the previous eight decades. This reform is expected to significantly restructure the energy sector and boost and diversify the energy production. Moreover, changes in the energy sector and production might lead to structural changes in the rest of the economy and ultimately generate significant economic benefits for the country. Nevertheless, the fundamental role of the energy sector in this oil producing country makes the potential impacts of the reform complex to forecast. The objective of the study is to analyze the current state, evolution, and driving factors of the total primary energy use in Mexico in 2003–2012 (prior to the implementation of the reform as a precedent for future analyses of impacts of the energy reform. The results show three driving factors of the evolution of primary energy use: final non-energy demand, direct energy intensity, and economic structure. Also, it was found that the energy sector has been in a precarious situation regarding its structure and efficiency. However, this situation had a small effect on the evolution of primary energy use.

  5. Precise Measurement of the $\\bar{p}p$ Total Cross-Section in the ISR Energy Range

    CERN Multimedia

    2002-01-01

    The major aim of this experiment is the precise measurement of the antiproton-proton total cross-section in the ISR energy range, using the total-rate method. The proton-proton total cross-section is remeasured with the same method and the same apparatus, and a precision of 0.5\\% is expected for both cross-sections. The total-rate method consists in the simultaneous measurement of the total interaction rate and the ISR luminosity. This is done with a set of scintillation-counter hodoscopes covering over 99.99\\% of the solid angle, which are sensitive to over 95\\% of all interactions. In addition to these detectors, small-angle drift-tube hodoscopes are used to measure the differential elastic cross-section as a function of the momentum transfert t. The total cross-section can be measured independently by extrapolating this differential cross-section to the forward direction and invoking the optical theorem. A study of the general features of charged-particle production is performed using finely divided scinti...

  6. Misreporting of energy intake in the elderly using doubly labeled water to measure total energy expenditure and weight change.

    Science.gov (United States)

    Shahar, Danit R; Yu, Binbing; Houston, Denise K; Kritchevsky, Stephen B; Newman, Anne B; Sellmeyer, Deborah E; Tylavsky, Frances A; Lee, Jung Sun; Harris, Tamara B

    2010-02-01

    One of the major problems in dietary assessment is inaccuracy in reporting diet. To examine the association between self-reported energy intake (EI) by food frequency questionnaire (FFQ) and energy expenditure (EE), measured by doubly labeled water (DLW), among older persons. EE was assessed in 298 high-functioning, community-dwelling older adults (70-79 years of age) over a 2-week period using DLW. Dietary intake was assessed using a Block FFQ. The ratio between reported EI and total energy expenditure (TEE) was calculated. Misreporting was defined as follows: participants with an EI/TEE ratio of reporters, while participants with an EI/TEE ratio >1.28 were categorized as high energy reporters. Participants with an EI/TEE ratio of 0.77-1.28 were categorized as "true" energy reporters. One-year percent weight change prior to EE visit was used as another validation indicator. Participants who were low energy reporters but lost >2% of their body weight were categorized as undereaters. Two hundred ninety-six participants provided both FFQ and DLW measurements. Forty-three percent of participants were low energy reporters; among them, almost 30% lost weight and, therefore, were categorized as undereaters. The undereaters consumed significantly fewer calories. No difference in the frequency of low energy reporting was detected between genders or racial groups. Underreporters had significantly higher body weight than "true" or high reporters. Undereaters tended to have higher body mass index than the underreporters. Undereating is prevalent in the elderly and may be falsely perceived as underreporting. It should be further addressed and characterized in future studies.

  7. Specific features of energy and spatial distribution of primary knocked-out atoms in monocrystals

    International Nuclear Information System (INIS)

    Taratin, A.M.; Vorob'ev, S.A.

    1978-01-01

    By simulation trajectories of 0.2 MeV protons in 1 μm thick Al monocrystal, the energy and spatial distributions of primary atoms knocked out by the protons (PKA) have been studied. Different orientations of the incident beam axis relative to the densely packed direction in the case of ''quasichanneling'' and ''chaotic'' scattering of particles by the crystal have been researched. The depth dependence of the number of generated PKA, their distribution in the plane transverse to the preferred direction, and the energy spectrum of PKA have been obtained. It is shown that the PKA volume density is higher than that obtained using evaluations not accounting for the crystalline structure, and the energy spectrum contains more low energy PKAs. A concept of the cross section of the PKA production on an atomic chain is introduced for ipterpretation of the data obtained

  8. The rise of the proton-(anti)proton total cross section at tevatron energies and beyond

    International Nuclear Information System (INIS)

    Kluit, P.M.; Timmermans, J.

    1987-12-01

    A dispersion relation analysis of the UA4 result on the real part of the panti p elastic scattering amplitude is presented. The interpretation is twofold. Assuming that the pp and panti p cross sections are asymptotically identical, a steep rise is deduced of the total cross section in the 1-4 TeV domain. In case the pp and panti p cross sections are asymptotically different, it is deduced that there is a crossing of the total cross section of pp and panti p between ISR and Spanti pS energies followed by a steep rise of the difference of the pp and panti p total cross sections. It is shown that in both cases this rise can be accounted for if we add an additional term with an energy cut-off to the usual Amaldi parametrisation of the total cross section: ln 2 (s/s cut ) in the first case, or ln(s/s cuto ) in the second case, where √s cut lies around 500 GeV and √s cuto around 63 GeV. Both quantities can be interpreted as a threshold of a new process. For the first case, a continuous parametrisation without a threshold is also proposed with an extra term of the form ln 2 (1+ s/s 1 ), where √s 1 equals 700 GeV. 12 refs.; 5 figs.; 3 tabs

  9. Energy balance from Bahia state 2013 - series 1996-2012

    International Nuclear Information System (INIS)

    2013-01-01

    This Energy Balance from Bahia, Brazil, presents six chapters, as follows: the chapter 1 approaches the profile of the energy system, showing the structure of the Bahia state energy matrix in the year of 2012, and the modifications occurred during the period of 1996-2012. Then the consolidated information are presented, from production to final consumption, for the set of primary and secondary sources, as well as comparative tables of states x national production of major energy production; the chapter 2 analyses the development, during the period of 1996-2012, in energy supply according to the Primary and Secondary sources; the chapter 3 comprised the evolution of energy consumption by sources and according the social-economic sectors; chapter 4 focus, within a broader view, the evolution of self-sufficiency energy state, confronting the production of primary energy to the total energy demand; in chapter 5 is given the status of the Energy Transformation Centers of the state, highlighting the balances of the Refinery Landulpho Alves (RLAM) and the Power Plants of Public Service and Self-Producer and the chapter 6 contains the consolidated matrixes expressed in the years of 1980, 1985 and 1990-2012

  10. Extraction of topographic and material contrasts on surfaces from SEM images obtained by energy filtering detection with low-energy primary electrons.

    Science.gov (United States)

    Nagoshi, Masayasu; Aoyama, Tomohiro; Sato, Kaoru

    2013-01-01

    Secondary electron microscope (SEM) images have been obtained for practical materials using low primary electron energies and an in-lens type annular detector with changing negative bias voltage supplied to a grid placed in front of the detector. The kinetic-energy distribution of the detected electrons was evaluated by the gradient of the bias-energy dependence of the brightness of the images. This is divided into mainly two parts at about 500 V, high and low brightness in the low- and high-energy regions, respectively and shows difference among the surface regions having different composition and topography. The combination of the negative grid bias and the pixel-by-pixel image subtraction provides the band-pass filtered images and extracts the material and topographic information of the specimen surfaces. Copyright © 2012 Elsevier B.V. All rights reserved.

  11. Deployment of national resources in the provision of energy in the United Kingdom, 1975-2025

    International Nuclear Information System (INIS)

    1977-01-01

    The principal sections of the report are headed: unit capital costs (primary energy sources - coal, oil, natural gas, nuclear, alternative primary energy; conversion; transmission and distribution; storage related to electricity supply; district heating); economic base; capital cost by scenarios; total capital costs by scenarios; cost of balancing imports; materials; manpower; land use; conclusions and recommendations. (U.K.)

  12. Early results of Latitude primary total elbow replacement with a minimum follow-up of 2 years.

    Science.gov (United States)

    Mehta, Saurabh S; Watts, Adam C; Talwalkar, Sumedh C; Birch, Ann; Nuttall, David; Trail, Ian A

    2017-10-01

    The aim of this study was to present outcomes of primary Latitude total elbow replacement (TER) with a minimum follow-up of 2 years. A retrospective cohort study was undertaken with prospective outcome data collection for the latest outcome. Included were 63 consecutive primary Latitude TERs in 58 patients performed during a period of 5 years at a specialist orthopedic hospital. The mean age of the patients was 62 years (33-85 years). Five primary TERs (4 patients) were lost to follow-up. The primary diagnosis was rheumatoid arthritis in 49, osteoarthritis in 8, and trauma in 6 elbows. The mean flexion-extension arc was 75° preoperatively and 97° postoperatively. Mean postoperative Elbex pain score was 19/100, and function score was 37/100. Mean postoperative scores were 42/100 for the Quick Disabilities of the Arm, Shoulder, and Hand and 38/50 for the elbow-specific American Shoulder and Elbow Surgeons assessment. Four patients died of unrelated causes, and 8 of 63 underwent further surgical intervention, including explantation and conversion from unlinked to linked implant. On radiographic review of 41 surviving TERs, aseptic radiologic loosening was observed of the humeral component in 4 elbows and of the ulnar component in 9. Seven elbows had no radial component, and of the remaining 34 elbows, 16 (47%) had signs of loosening of the radial implant. Complications included 1 heterotopic ossification, 1 olecranon fracture, and 3 further procedures for ulnar nerve entrapment. The results indicate that the early outcome of Latitude TER is comparable to that of other prostheses. There is concern about early radiologic loosening of the radial component. Crown Copyright © 2017. Published by Elsevier Inc. All rights reserved.

  13. Energy consumption modeling during dairy sewage pretreatment

    Directory of Open Access Journals (Sweden)

    Dąbrowski Wojciech

    2017-01-01

    Full Text Available The research was conducted in a dairy WWTP located in north-eastern Poland with the average flow of 546 m3d-1 and PE 11500 in 2016. Energy consumption was measured with the help of Lumel 3-phase network parameter transducers installed within the plant. The modeling was conducted based on the quantity and quality of raw sewage, after its screening, averaging and dissolved air flotation. The following parameters were determined: BOD5, COD. N-total and P-total. During the research period. 15 measurement series were carried out. Pollution loads removed in primary treatment varied from 167.0 to 803.5 kgO2d-1 and 1205.9 to 10032 kgO2d-1 for BOD5 and COD respectively. The energy consumption share during dairy pretreatment in relation to the total energy consumption was in the range from 13.8 to 28.5% with the mean value of 18.7% during the research period. Energy consumption indicators relating to removed pollution loads for primary treatment were established with the mean values of 0.74 and 0.83 kWhkg-1d-1 for BOD5 and COD respectively. An attempt was made to determine the influence of raw sewage characteristics and pretreatment efficiency on energy consumption of the object. A model of energy consumption during pretreatment was estimated according to the experimental data obtained in the research period. It was modeled using the linear regression model and principal component analysis.

  14. USSR energy efficiency and prospects

    International Nuclear Information System (INIS)

    Sinyak, Y.

    1991-06-01

    The U.S.S.R. is the largest energy producer and the second largest energy consumer in the world. Its share of global energy use reached above 17% in 1988. The soviet energy system is characterized by low efficiency and high per capita energy consumption, although there are some reasons justifying the greater U.S.S.R. energy use per unit of product output than in other industrialized countries. The present energy-savings potential is approximately equal to one-half of the domestic energy consumption. Improvements in energy efficiency at all levels of the national economy are now considered to be the primary goal of national energy policy for the next couple of decades. Being endowed with abundant natural gas resources, the U.S.S.R. will count on this energy source in the future to improve its energy efficiency, reduce expenses and cope with air pollution. After 2005-2010, stabilized primary energy consumption may be reached or there may even be a decline of total energy use. The U.S.S.R. could reduce CO 2 emissions by 20% by 2030 but with substantial negative impacts on GNP growth. Required improvements in the Soviet energy system depend on changes in energy management, including reduction of the role of centralized planning, decentralization and privatization of energy-producing facilities, energy-price reforms, reshaping of investment patterns, reduction in military expenditures, etc. (author)

  15. Patient-Reported Esthetic and Functional Outcomes of Primary Total Laparoscopic Intestinal Vaginoplasty in Transgender Women With Penoscrotal Hypoplasia.

    Science.gov (United States)

    Bouman, Mark-Bram; van der Sluis, Wouter B; van Woudenberg Hamstra, Leonora E; Buncamper, Marlon E; Kreukels, Baudewijntje P C; Meijerink, Wilhelmus J H J; Mullender, Margriet G

    2016-09-01

    Puberty-suppressing hormonal treatment may result in penoscrotal hypoplasia in transgender women, making standard penile inversion vaginoplasty not feasible. For these patients, intestinal vaginoplasty is a surgical alternative, but knowledge on patient-reported postoperative outcomes and quality of life is lacking. To assess patient-reported functional and esthetic outcomes, quality of life, satisfaction, and sexual well-being after primary total laparoscopic intestinal vaginoplasty in transgender women. A survey study was performed on transgender women who underwent primary total laparoscopic intestinal vaginoplasty with at least 1 year of clinical follow-up. Thirty-one transgender women completed the questionnaires (median age at time of surgery = 19.1 years, range = 18.3-45.0) after a median clinical follow-up of 2.2 years (range = 0.8-7.5). Consenting women were asked to complete a combined questionnaire of the Subjective Happiness Scale, the Satisfaction With Life Scale, Cantril's Ladder of Life Scale, the Female Sexual Function Index, the Female Genital Self-Imaging Scale, the Amsterdam Hyperactive Pelvic Floor Scale-Women, and a questionnaire addressing postoperative satisfaction. Patient-reported functional and esthetic outcomes and postoperative quality of life. Patients graded their life satisfaction a median of 8.0 (range = 4.0-10.0) on Cantril's Ladder of Life Scale. Patients scored a mean total score of 27.7 ± 5.8 on the Satisfaction With Life Scale, which indicated high satisfaction with life, and a mean total score of 5.6 ± 1.4 on the Subjective Happiness Scale. Functionality was graded a median score of 8.0 of 10 (range = 1.0-10.0) and esthetics a score of 8.0 out of 10 (range = 3.0-10.0). The mean Female Sexual Function Index total score of sexually active transgender women was 26.0 ± 6.8. This group of relatively young transgender women reported satisfactory functional and esthetic results of the neovagina and a good quality of life

  16. Energy Toolbox—Framework for the Development of a Tool for the Primary Design of Zero Emission Buildings in European and Asian Cities

    Directory of Open Access Journals (Sweden)

    Christoph Koller

    2017-12-01

    Full Text Available This paper discusses the framework for the development of an Energy Toolbox (ETB. The aim of the ETB is to support the design of domestic Zero Emission Buildings (ZEBs, according to the concept of net zero-energy buildings during the early architectural design and planning phases. The ETB concept is based on the calculation of the energy demand for heating, cooling, lighting, and appliances. Based on a building’s energy demand, technologies for the onsite conversion and production of the specific forms and quantities of final and primary energy by means of renewable energy carriers can be identified. The calculations of the ETB are based on the building envelope properties of a primary building design, as well as the physical and climate parameters required for the calculation of heat transfer coefficients, heat gains, and heat losses. The ETB enables the selection and rough dimensioning of technologies and systems to meet, and, wherever possible, reduce the thermal and electric energy demand of a building. The technologies included comprise green facades, adaptable dynamic lighting, shading devices, heat pumps, photovoltaic generators, solar thermal collectors, adiabatic cooling, and thermal storage. The ETB facilitates the balancing of the energy consumption and the production of renewable energies of a primary building design.

  17. Total and elastic electron scattering cross sections from Xe at intermediate and high energies

    International Nuclear Information System (INIS)

    Garcia, G; Pablos, J L de; Blanco, F; Williart, A

    2002-01-01

    Experimental total electron scattering cross sections from Xe in the energy range 300-5000 eV have been obtained with experimental errors of about 3%. The method was based on the measurement of the attenuation of a linear electron beam through a Xe gas cell in combination with an electron spectroscopy technique to analyse the energy of the transmitted electrons. Differential and integral elastic cross sections have been calculated using a scattering potential method which includes relativistic effects. The consistency of our theoretical and experimental results is also discussed in the paper. Finally, analytical formulae depending on two parameters, namely the number of target electrons and the atomic polarizability, are given to reproduce the experimental data for Ne, Ar, Kr and Xe in the energy range 500-10 000 eV

  18. Do large heads enhance stability and restore native anatomy in primary total hip arthroplasty?

    Science.gov (United States)

    Lombardi, Adolph V; Skeels, Michael D; Berend, Keith R; Adams, Joanne B; Franchi, Orlando J

    2011-06-01

    Dislocation remains a serious complication in hip arthroplasty. Resurfacing proponents tout anatomic femoral head restoration as an advantage over total hip arthroplasty. However, advances in bearings have expanded prosthetic head options from traditional sizes of 22, 26, 28, and 32 mm to diameters as large as 60 mm. Large heads reportedly enhance stability owing to increased range of motion before impingement and increased jump distance to subluxation. Available larger diameter material combinations include metal- or ceramic-on-highly crosslinked polyethylene and metal-on-metal, each with distinct advantages and disadvantages. We sought to determine (1) if using larger diameter heads has lowered our dislocation rate; and (2) how closely an anatomic metal-on-metal bearing with diameters to 60 mm replicates native femoral head size. We retrospectively reviewed 2020 primary arthroplasties performed with large heads (≥ 36 mm) in 1748 patients and noted dislocation incidence. In a prospective subset of 89 cases using anatomic heads, native femoral head diameter was measured intraoperatively with calipers by an independent observer and later compared with implanted size. One dislocation has occurred in 2020 hips for an incidence of 0.05%. The prosthetic head averaged 0.7 mm larger than the native head with 68 of 89 (76%) reconstructed to within ± 2 mm of native size. Larger diameter heads have contributed to lower dislocation rates and large-diameter metal-on-metal articulation can provide close anatomic restoration in primary THA.

  19. Monte-Carlo simulation of primary electrons in the matter for the generation of x-rays

    International Nuclear Information System (INIS)

    Bendjama, H.; Laib, Y.; Allag, A.; Drai, R.

    2006-01-01

    The x-rays imagining chains components from the source to the detector, rest on the first part of simulation to the energy production of x-rays emission (source), which suggest us to identified the losses energies result from interaction between the fast electrons and the particles of metal : the energies losses due to 'collisional losses' (ionization, excitation) and radiative losses. For the medium and the primary electron energy which interests us, the electrons slowing down in the matter results primarily from the inelastic collisions; whose interest is to have to simulate the x-rays characteristic spectrum. We used a Monte-Carlo method to simulate the energy loss and the transport of primary electrons. This type of method requires only the knowledge of the cross sections attached to the description of all the elementary events. In this work, we adopted the differential cross section of Mott and the total cross section of inner-shell ionization according to the formulation of Gryzinski, to simulate the energy loss and the transport of primary electrons respectively. The simulation allows to follow the electrons until their energy reaches the atomic ionization potential of the irradiated matter. The differential cross section of Mott gives us a very good representation of the pace of the distribution of the energy losses. The transport of primary electron is approximately reproduced

  20. Short primary linear drive designed for synchronous and induction operation mode with on-board energy storage

    Energy Technology Data Exchange (ETDEWEB)

    Fernandes Neto, Tobias Rafael

    2012-06-28

    The idea of a flexible industrial manufacturing system for the transfer of material, tooling, processing/filling, etc., in which several vehicles can travel with high speed, high degree of independency and high precision is proposed in this thesis. Such flexible systems show a meaningful economic potential for modern manufacturing systems. The basic concept is that a linear motor has the secondary part fixed to the track while the primary (moving winding) travels along the track (short primary topology). The same principle can work in the other way around, arranging the primary in segments and letting the secondary (carrier) to move from segment to segment (long primary topology). The concept's implementation involves technical issues, such as: the position measurement, the energy and information transfer, the individual position and speed control of the vehicle in which varying speeds increase the possibility of collision, and the smooth transition between segments or different types of the secondary. Finally, multiple vehicles traveling at high speed, high positioning repeatability and rapid acceleration rates increase the production throughout and the reliability compared to conventional manufacturing conveyor systems. As an example, a transporting and processing system based on linear drives is a continuous and closed structure with multiple loops, which permits the safe transport of fragile loads. Although such solutions often need higher investment costs, the lack of mechanical coupling parts and wearing elements in these motors greatly increases their reliability. The long primary topology allows a passive and lightweight vehicle (secondary), avoiding brushes and cables to transfer energy and information. For long distances, the primary is arranged in several electrical independent segments. On the other hand, the short primary configuration uses the winding mounted on the moving part (active vehicle) to produce the traveling wave, the secondary as

  1. [Intra-Articular Application of Tranexamic Acid Significantly Reduces Blood Loss and Transfusion Requirement in Primary Total Knee Arthroplasty].

    Science.gov (United States)

    Lošťák, J; Gallo, J; Špička, J; Langová, K

    2016-01-01

    PURPOSE OF THE STUDY The aim of this prospective study was to investigate the effect of topical application of tranexamic acid (TXA, Exacyl) on the amount of post-operative blood loss, and blood transfusion requirement in patients undergoing primary total knee arthroplasty (TKA). Attention was paid to early complications potentially associated with TXA administration, such as haematoma, wound exudate, or knee swelling. In addition, the economic benefit of TXA treatment was also taken into account. MATERIAL AND METHODS The study included 238 patients (85 men and 153 women) who underwent primary total knee arthroplasty (TKA) at our department between January 2013 and November 2015. A group of 119 patients (41 men and 78 women) received intraarticular TXA injections according to the treatment protocol (TXA group). A control group matched in basic characteristics to the TXA group also consisted of 119 patients. The average age in the TXA group was 69.8 years, and the most frequent indication for TKA surgery was primary knee osteoarthritis (81.5%). In each patient, post-operative volume of blood lost from drains and total blood loss including hidden blood loss were recorded, as well as post-operative haemoglobin and haematocrit levels. On discharge of each patient from hospital, the size and site of a haematoma; wound exudate, if present after post-operative day 4; joint swelling; range of motion and early revision surgery, if performed, were evaluated. Requirements of analgesic drugs after surgery were also recorded. RESULTS In the TXA group, blood losses from drains were significantly lower than in the control group (456.7 ± 270.8 vs 640.5 ±448.2; p = 0.004). The median value for blood losses from drains was lower by 22% and the average value for total blood loss, including hidden losses, was also lower than in the control group (762.4 ± 345.2 ml vs 995.5 ± 457.3 ml). The difference in the total amount of blood loss between the two groups was significant (p = 0

  2. Absolute total and one and two electron transfer cross sections for Ar8+ on Ar as a function of energy

    International Nuclear Information System (INIS)

    Vancura, J.; Kostroun, V.O.

    1992-01-01

    The absolute total and one and two electron transfer cross sections for Ar 8+ on Ar were measured as a function of projectile laboratory energy from 0.090 to 0.550 keV/amu. The effective one electron transfer cross section dominates above 0.32 keV/amu, while below this energy, the effective two electron transfer starts to become appreciable. The total cross section varies by a factor over the energy range explored. The overall error in the cross section measurement is estimated to be ± 15%

  3. Inpatient Consults and Complications During Primary Total Joint Arthroplasty in a Bundled Care Model.

    Science.gov (United States)

    Baumgartner, Billy T; Karas, Vasili; Kildow, Beau J; Cunningham, Daniel J; Klement, Mitchell R; Green, Cindy L; Attarian, David E; Seyler, Thorsten M

    2018-04-01

    The Centers for Medicare and Medicaid Services (CMS) are implementing changes in hospital reimbursement models for total joint arthroplasty (TJA), moving to value-based bundled payments from the fee-for-service model. The purpose of this study is to identify consults and complications during the perioperative period that increase financial burden. We combined CMS payment data for inpatient, professional, and postoperative with retrospective review of patients undergoing primary TJA and developed profiles of patients included in the Comprehensive Care for Joint Replacement bundle undergoing TJA. Statistical comparison of episode inpatient events and payments was conducted. Multiple regression analysis was adjusted for length of stay, disposition, and Charlson-Deyo comorbidity profile. Median total payment was $21,577.36, which exceeded the median bundle target payment of $20,625.00. Adjusted analyses showed that psychiatry consults (increase of $73,123.32; P care unit admission ($14,078.37; P care unit admission, and medical/psychiatric consultation exceeded the CMS target. Although study results showed typical complication rates, acute inpatient consultation significantly increased utilization beyond the CMS target even when adjusted for length of stay, patient comorbidities, and discharge. Needed medical care should continue to be a priority for inpatients, and allowance for individual outliers should be considered in policy discussions. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. Energy handbook. 2008 edition

    International Nuclear Information System (INIS)

    2008-01-01

    This memento about energy provides a series of tables with numerical data relative to energy resources and uses in France, in the European Union and in the rest of the world: energy consumption and demand (primary energy demand, consumption, and efficiency per region and per source. Forecasting, CO 2 emissions, energy independence, supplies, uses and imports, demand scenarios, energy savings..), power production (production per geopolitical region, in OECD countries and in France. Peak load demand, power consumption and generation in France. Hydro-power and thermal plants in France. Total capacity, forecasts and exports), nuclear power (production, forecasting, reactors population, characteristics of French PWRs, uranium needs and fuel cycle), energy resources (renewable energies, fossil fuels and uranium reserves and production), economic data (gross national product, economic and energy indicators, prices and cost estimations), energy units and conversion factors (counting, calorific value of coals, production costs, energy units). (A.L.B.)

  5. Energy data book 2000

    International Nuclear Information System (INIS)

    2000-01-01

    This memento about energy provides a series of tables with numerical data relative to energy resources and uses in France, in the European Union and in the rest of the world: energy consumption and demand (primary energy demand, consumption, and efficiency per region and per source; forecasting, CO 2 emissions, energy independence, supplies, uses and imports, demand scenarios, energy savings..), power production (production per geopolitical region, in OECD countries and in France; peak load demand, power consumption and generation in France; hydro-power and thermal plants in France; total capacity, forecasts and exports), nuclear power (production, forecasting, reactors population, characteristics of French PWRs, uranium needs and fuel cycle), energy resources (renewable energies, fossil fuels and uranium reserves and production), economic data (gross national product, economic and energy indicators, prices and cost estimations), energy units and conversion factors (counting, calorific value of coals, production costs, energy units). (J.S.)

  6. Relationship of Energy Growth to Economic Growth under Alternative Energy Policies

    Energy Technology Data Exchange (ETDEWEB)

    Behling, Jr., D. J.; Dullien, R.; Hudson, E.

    1976-03-01

    This report is the first of a series of studies that will analyze the economic and social impacts of research, development, and demonstration plans of the Energy Research and Development Administration. Two policy proposals were examined against a Base Case set of economic and energy projections for the years 1985, 1990, and 2000: (1) the introduction of RD and D-initiated energy supply and end-use conversion technologies to expand domestic energy supply and to improve the efficiency and flexibility of its use; and (2) the imposition of taxes and tariffs on petroleum and natural gas to reduce demand for these primary energy sources. Targets for the amounts of imports of oil and gas were specified by ERDA as follows: 10 percent (or less) of total U.S. energy consumption in 1985; 8 percent (or less) of total U.S. energy consumption in 1990; and 5 percent (or less) of total U.S. energy consumption in 2000. The purpose of the analysis was to first identify the degree to which the introduction of new energy technologies and/or the imposition of energy taxes could reduce oil and gas imports toward the target levels; and second, to estimate the effects of these policies on the economy and the environment. These economic and environmental effects are thus a measure of the costs associated with meeting the import targets. The benefits of these policies, in the form of increased economic and political security were not measured. The analysis was based on an analytic framework which linked detailed mathematical process engineering and economic models to more aggregate econometric models. The four models employed are described.

  7. Energy infrastructure: hydrogen energy system

    Energy Technology Data Exchange (ETDEWEB)

    Veziroglu, T N

    1979-02-01

    In a hydrogen system, hydrogen is not a primary source of energy, but an intermediary, an energy carrier between the primary energy sources and the user. The new unconventional energy sources, such as nuclear breeder reactors, fusion reactors, direct solar radiation, wind energy, ocean thermal energy, and geothermal energy have their shortcomings. These shortcomings of the new sources point out to the need for an intermediary energy system to form the link between the primary energy sources and the user. In such a system, the intermediary energy form must be transportable and storable; economical to produce; and if possible renewable and pollution-free. The above prerequisites are best met by hydrogen. Hydrogen is plentiful in the form of water. It is the cheapest synthetic fuel to manufacture per unit of energy stored in it. It is the least polluting of all of the fuels, and is the lightest and recyclable. In the proposed system, hydrogen would be produced in large plants located away from the consumption centers at the sites where primary new energy sources and water are available. Hydrogen would then be transported to energy consumption centers where it would be used in every application where fossil fuels are being used today. Once such a system is established, it will never be necessary to change to any other energy system.

  8. Summarized achievement report on research and development in the Sunshine Project in fiscal 1979. Research on hydrogen energy total systems; 1979 nendo suiso energy total system no kenkyu seika hokokusho

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1980-03-01

    This paper describes discussions on future possibility of introducing hydrogen, by adding the latest data acquired in fiscal 1979 into a hydrogen energy total system calculation model. The critical cost of hydrogen is higher always than other secondary energies up to about 2030. Since it is a presupposition that hydrogen manufacturing is technologically feasible only by using the electrolytic manufacturing process, the hydrogen cost changes with the critical cost of electric power. Thereafter, if a hydrogen manufacturing process of mixed type utilizing heat from a high temperature gas reactor (HTGR) is introduced, the cost will be reduced. However, introduction of HTGR is governed by the nuclear power plan such as HTGR technology development, rather than simply by the economic performance. Value factors showing qualitative advantage of hydrogen have been assigned to different demand sectors, whereas acceptable economic performance may emerge from this effect from about 2010 in sectors having large value factors (such as 2.8 in aircraft fuels). Hydrogen contribution would be about 2.1% in 2020 and 5.5% in 2030 of the whole energy demand. (NEDO)

  9. Life Cycle Primary Energy and Carbon Analysis of Recovering Softwood Framing Lumber and Hardwood Flooring for Reuse

    Science.gov (United States)

    Richard D. Bergman; Hongmei Gu; Thomas R. Napier; James Salazar; Robert H. Falk

    2012-01-01

    Recovering wood for reuse in a new house affects energy and greenhouse gas emissions. This paper finds the energy and emissions for recovering softwood framing lumber and hardwood flooring from an old house for installation in a new house. Recovering wood displaces primary production of new wood products and avoids the end-of-life (EOL) burdens for the old house. We...

  10. Photon beam convolution using polyenergetic energy deposition kernels

    International Nuclear Information System (INIS)

    Hoban, P.W.; Murray, D.C.; Round, W.H.

    1994-01-01

    In photon beam convolution calculations where polyenergetic energy deposition kernels (EDKs) are used, the primary photon energy spectrum should be correctly accounted for in Monte Carlo generation of EDKs. This requires the probability of interaction, determined by the linear attenuation coefficient, μ, to be taken into account when primary photon interactions are forced to occur at the EDK origin. The use of primary and scattered EDKs generated with a fixed photon spectrum can give rise to an error in the dose calculation due to neglecting the effects of beam hardening with depth. The proportion of primary photon energy that is transferred to secondary electrons increases with depth of interaction, due to the increase in the ratio μ ab /μ as the beam hardens. Convolution depth-dose curves calculated using polyenergetic EDKs generated for the primary photon spectra which exist at depths of 0, 20 and 40 cm in water, show a fall-off which is too steep when compared with EGS4 Monte Carlo results. A beam hardening correction factor applied to primary and scattered 0 cm EDKs, based on the ratio of kerma to terma at each depth, gives primary, scattered and total dose in good agreement with Monte Carlo results. (Author)

  11. The primary exposure standard of ENEA for medium energy X-ray: characteristics and measurements procedures

    International Nuclear Information System (INIS)

    Laitano, R.F.; Toni, M.P.

    1983-01-01

    A description is given of a medium energy X-ray free-air chamber used, as primary exposure standard, at the Laboratorio di Metrologia delle Radiazioni Ionizzanti of the Enea in Italy. The main features of an X-ray facility for the production of radiation between 40 KeV and 400 KeV are also described. The measurements procedures are then analyzed with respect to the realization of the exposure unit in the relevant energy range. Finally the results of some international comparisons are reported

  12. Circumferential electrocautery of the patella in primary total knee replacement without patellar replacement: a meta-analysis and systematic review

    Science.gov (United States)

    Fan, Lihong; Ge, Zhaogang; Zhang, Chen; Li, Jia; Yu, Zefeng; Dang, Xiaoqian; Wang, Kunzheng

    2015-03-01

    The purpose of this meta-analysis and systematic review was to identify and assess whether circumferential electrocautery is useful for improving outcomes after primary total knee replacement(TKR). We searched MEDLINE, EMBASE, PubMed, SpringerLink, Web of Knowledge, OVID CINAHL, OVID EBM and Google Scholar and included articles published through January 2014. A total of 6 articles met the inclusion criteria. Of the 776 cases included in the analysis, 388 cases involved patellar denervation, and 388 cases were designated as the control group. The meta-analysis revealed no significant difference in the incidence of anterior knee pain (AKP, p = 0.18) or in the visual analogue scale score (VAS, p = 0.23) between the two groups. In addition, AKSS Function Score indicated no significant difference between the two groups (p = 0.28). However, the OKS (p = 0.02), patellar score (p = 0.01), AKSS-Knee Score (p = 0.004), range of motion (ROM, p electrocautery. The results indicate that circumferential electrocautery of the patella does not significantly improve AKP compared with non-electrocautery techniques but that circumferential electrocautery significantly improves patients' knee function after surgery. Therefore, we believe that circumferential electrocautery is beneficial to the outcome of primary TKR surgery without patellar replacement.

  13. Empirical Study on Total Factor Productive Energy Efficiency in Beijing-Tianjin-Hebei Region-Analysis based on Malmquist Index and Window Model

    Science.gov (United States)

    Xu, Qiang; Ding, Shuai; An, Jingwen

    2017-12-01

    This paper studies the energy efficiency of Beijing-Tianjin-Hebei region and to finds out the trend of energy efficiency in order to improve the economic development quality of Beijing-Tianjin-Hebei region. Based on Malmquist index and window analysis model, this paper estimates the total factor energy efficiency in Beijing-Tianjin-Hebei region empirically by using panel data in this region from 1991 to 2014, and provides the corresponding political recommendations. The empirical result shows that, the total factor energy efficiency in Beijing-Tianjin-Hebei region increased from 1991 to 2014, mainly relies on advances in energy technology or innovation, and obvious regional differences in energy efficiency to exist. Throughout the window period of 24 years, the regional differences of energy efficiency in Beijing-Tianjin-Hebei region shrank. There has been significant convergent trend in energy efficiency after 2000, mainly depends on the diffusion and spillover of energy technologies.

  14. Long-Term Primary Patency Rate After Nitinol Self-Expandable Stents Implantation in Long, Totally Occluded Femoropopliteal (TASC II C & D) Lesions.

    Science.gov (United States)

    Elmahdy, Mahmoud Farouk; Buonamici, Piergiovanni; Trapani, Maurizio; Valenti, Renato; Migliorini, Angela; Parodi, Guido; Antoniucci, David

    2017-06-01

    Endovascular therapy for long femoropopliteal lesions using percutaneous transluminal balloon angioplasty or first-generation of peripheral stents has been associated with unacceptable one-year restenosis rates. However, with recent advances in equipment and techniques, a better primary patency rate is expected. This study was conducted to detect the long-term primary patency rate of nitinol self-expandable stents implanted in long, totally occluded femoropopliteal lesions TransAtlantic Inter-Society Census (TASC II type C & D), and determine the predictors of reocclusion or restenosis in the stented segments. The demographics, clinical, anatomical, and procedural data of 213 patients with 240 de novo totally occluded femoropopliteal (TASC II type C & D) lesions treated with nitinol self-expandable stents were retrospectively analysed. Of these limbs, 159 (66.2%) presented with intermittent claudication, while 81 (33.8%) presented with critical limb ischaemia. The mean-time of follow-up was 36±22.6 months, (range: 6.3-106.2 months). Outcomes evaluated were, primary patency rate and predictors of reocclusion or restenosis in the stented segments. The mean age of the patients was 70.9±9.3 years, with male gender 66.2%. Mean pre-procedural ABI was 0.45±0.53. One-hundred-and-seventy-five (73%) lesions were TASC II type C, while 65 (27%) were type D lesions. The mean length of the lesions was 17.9±11.3mm. Procedure related complications occurred in 10 (4.1%) limbs. There was no periprocedural mortality. Reocclusion and restenosis were detected during follow-up in 45 and 30 limbs respectively, and all were re-treated by endovascular approach. None of the patients required major amputation. Primary patency rates were 81.4±1.1%, 77.7±1.9% and 74.4±2.8% at 12, 24, and 36 months respectively. Male gender, severe calcification, and TASC II D lesion were independent predictors for reocclusion, while predictors of restenosis were DM, smoking and TASC II D lesions

  15. Estimates of the cost and energy consumption of aluminum-air electric vehicles

    Science.gov (United States)

    Cooper, J. F.

    1980-11-01

    Economic costs and primary energy consumption are estimated for general purpose electric vehicles using aluminum-air propulsion batteries within the time frame of the 1990's (earliest possible date of introduction). For an aluminum-air fuel economy of 36 tonne/km/kg-Al (optimized low-gallium alloys), a total refueling cost of 5.6 cents/km (1979$) was estimated for a 1.27 tonne vehicle. This is equivalent to $2 to 3/gal for automobiles of the same weight with fuel economies of 13.5 to 19.3 tonne-km/liter. The total primary energy consumption was estimated to be 1.3 to 1.7 kWh/km (coal) for the electric vehicle, which corresponds roughly to the energy cost of the automobiles using liquid fuels synthesized from coal. The energy consumption is 30 to 70 percent greater than the reference automobile using petroleum-derived gasoline.

  16. Total photon absorption

    International Nuclear Information System (INIS)

    Carlos, P.

    1985-06-01

    The present discussion is limited to a presentation of the most recent total photonuclear absorption experiments performed with real photons at intermediate energy, and more precisely in the region of nucleon resonances. The main sources of real photons are briefly reviewed and the experimental procedures used for total photonuclear absorption cross section measurements. The main results obtained below 140 MeV photon energy as well as above 2 GeV are recalled. The experimental study of total photonuclear absorption in the nuclear resonance region (140 MeV< E<2 GeV) is still at its beginning and some results are presented

  17. Energy for rural India

    International Nuclear Information System (INIS)

    Urban, Frauke; Benders, Rene M.J.; Moll, Henri C.

    2009-01-01

    About 72 million households in rural India do not have access to electricity and rely primarily on traditional biofuels. This research investigates how rural electrification could be achieved in India using different energy sources and what the effects for climate change mitigation could be. We use the Regional Energy Model (REM) to develop scenarios for rural electrification for the period 2005-2030 and to assess the effects on greenhouse gas emissions, primary energy use and costs. We compare the business-as-usual scenario (BAU) with different electrification scenarios based on electricity from renewable energy, diesel and the grid. Our results indicate that diesel systems tend to have the highest CO 2 emissions, followed by grid systems. Rural electrification with primarily renewable energy-based end-uses could save up to 99% of total CO 2 emissions and 35% of primary energy use in 2030 compared to BAU. Our research indicates that electrification with decentralised diesel systems is likely to be the most expensive option. Rural electrification with renewable energy tends to be the most cost-effective option when end-uses are predominantly based on renewable energy, but turns out to be more costly than grid extensions when electric end-use devices are predominantly used. This research therefore elaborates whether renewable energy is a viable option for rural electrification and climate change mitigation in rural India and gives policy recommendations.

  18. Measurement of the energy dependence of the total photon-proton cross section at HERA

    Energy Technology Data Exchange (ETDEWEB)

    Abramowicz, H. [Tel Aviv Univ. (Israel). Raymond and Beverly Sackler Faculty of Exact Sciences; Univ. Coll. London (United Kingdom); Krakow Univ. of Technology (Poland). Faculty of Physics, Mathematics and Applied Computer Science; Abt, I. [Max-Planck-Institut fuer Physik, Muenchen (Germany); Adamczyk, L. [AGH-Univ. of Science and Technology, Cracow (PL). Faculty of Physics and Applied Computer Science] (and others)

    2010-10-15

    The energy dependence of the photon-proton total cross section, {sigma}{sub tot}{sup {gamma}}{sup p}, was determined from e{sup +}p scattering data collected with the ZEUS detector at HERA at three values of the center-of-mass energy, W, of the {gamma}p system in the range 194

  19. Costs, CO{sub 2}- and primary energy balances of forest-fuel recovery systems at different forest productivity

    Energy Technology Data Exchange (ETDEWEB)

    Eriksson, Lisa; Gustavsson, Leif [Ecotechnology, Department of Engineering and Sustainable Development, Mid Sweden University, SE-831 25 Oestersund (Sweden)

    2010-05-15

    Here we examine the cost, primary energy use, and net carbon emissions associated with removal and use of forest residues for energy, considering different recovery systems, terrain, forwarding distance and forest productivity. We show the potential recovery of forest fuel for Sweden, its costs and net carbon emissions from primary energy use and avoided fossil carbon emissions. The potential annual net recovery of forest fuel is about 66 TWh, which would cost one billion EUR{sub 2005} to recover and would reduce fossil emissions by 6.9 Mt carbon if coal were replaced. Of the forest fuel, 56% is situated in normal terrain with productivity of >30 t dry-matter ha{sup -1} and of this, 65% has a forwarding distance of <400 m. In normal terrain with >30 t dry-matter ha{sup -1} the cost increase for the recovery of forest fuel, excluding stumps, is around 4-6% and 8-11% for medium and longer forwarding distances, respectively. The stump and small roundwood systems are less cost-effective at lower forest fuel intensity per area. For systems where loose material is forwarded, less dry-matter per hectare increases costs by 6-7%, while a difficult terrain increases costs by 3-4%. Still, these systems are quite cost-effective. The cost of spreading ash is around 40 EUR{sub 2005} ha{sup -1}, while primary energy use for spreading ash in areas where logging residues, stumps, and small roundwood are recovered is about 0.025% of the recovered bioenergy. (author)

  20. Utilizing primary energy savings and exergy destruction to compare centralized thermal plants and cogeneration/trigeneration systems

    International Nuclear Information System (INIS)

    Espirito Santo, Denilson Boschiero do; Gallo, Waldyr Luiz Ribeiro

    2017-01-01

    Rising energy conversion processes efficiencies reduces CO_2 emissions and global warming implications. Decentralized electricity production through cogeneration/trigeneration systems can save primary energy if it operates with high efficiency. High efficiency is obtained when the system produces electricity and a substantial amount of the energy rejected by the prime mover is used to meet site thermal demands. Environmental concerns and international agreements are directing governments of different countries to incentive high efficiency solutions. Centralized thermal plants and cogeneration/trigeneration efficiency are compared through efficiency indicators using the first law of thermodynamics and the second law of thermodynamics. This paper proposes the use of the primary energy savings analysis and the exergy destruction analysis to compare decentralized power production through cogeneration/trigeneration systems and centralized thermal plants. The analysis concluded that both methods achieve the same results if the thermal efficiency indicator is used to compare the methods. The analysis also revealed that trigeneration systems with the same energy input are comparable with quite different thermal efficiency centralized thermal plants. Case 1 is comparable to a 53% thermal efficiency power plant and case 2 is comparable to a 77% thermal efficiency power plant. - Highlights: • Trigeneration and thermal plants are compared using PES and exergy destruction. • The thermal efficiency indicator is used to compare both methods. • The same equivalent thermal efficiency is achieved by both methods. • Same energy input trigeneration is similar to different thermal efficiency plants. • Evaluated trigeneration are comparable to a 53–77% thermal efficiency power plant.

  1. Design of a bolometer for total-energy measurement of the linear coherent light source pulsed X-ray laser

    International Nuclear Information System (INIS)

    Friedrich, S.; Li, L.; Ott, L.L.; Kolgani, Rajeswari M.; Yong, G.J.; Ali, Z.A.; Drury, O.B.; Ables, E.; Bionta, R.M.

    2006-01-01

    We are developing a cryogenic bolometer to measure the total energy of the linear coherent light source (LCLS) free electron X-ray laser to be built at the Stanford Linear Accelerator Center. The laser will produce ultrabright X-ray pulses in the energy range between 0.8 and 8 keV with ∼10 12 photons per ∼200 fs pulse at a repeat interval of 8 ms, and will be accompanied by a halo of spontaneous undulator radiation. The bolometer is designed to determine the total energy of each laser pulse to within (1- x ) Sr x MnO 3 sensor array at the metal-insulator transition, where the composition x is adjusted to produce the desired transition temperature. We discuss design considerations and material choices, and present numerical simulations of the thermal response

  2. Humidified micro gas turbines for domestic users: An economic and primary energy savings analysis

    International Nuclear Information System (INIS)

    Montero Carrero, Marina; De Paepe, Ward; Bram, Svend; Musin, Frédéric; Parente, Alessandro; Contino, Francesco

    2016-01-01

    Micro Gas Turbines (mGTs) offer valuable advantages for small-scale Combined Heat and Power (CHP) production compared to reciprocating Internal Combustion Engines (ICEs): lower maintenance costs per kWh_e, cleaner exhaust, lower vibration levels and concentration of the residual heat in a single source (the exhaust gases). Nevertheless, mGTs have lower electrical efficiencies, fact that has prevented them from penetrating in the CHP market. Hot liquid water injection—by means of a saturation tower within the micro Humid Air Turbine (mHAT) cycle—allows both improving the flexibility of heat production and the electrical efficiency of mGTs; two qualities that if enhanced would increase the economic feasibility of the technology. Although the advantages of mHAT technology have been proven from a thermodynamic point of view, its economic performance has not yet been fully investigated. This paper presents a comparison of the economic profitability and the primary energy savings of an mGT, an ICE and an mHAT unit operating in real network conditions. Our aim is to investigate whether the increase in flexibility and electrical efficiency, achieved when transforming an mGT into an mHAT, allows this technology to economically outperform ICEs. Results show that the three units are viable in scenarios with high electricity and low natural gas prices. For the cases in which investment is feasible, the revenues with mHAT are the highest: thanks to their flexibility in heat generation, mHAT units are able to run all year long. On the other hand, the greatest primary energy savings are achieved with ICE units—which have the highest overall efficiencies—while mHAT savings are substantially lower. - Highlights: • We analyse the economics and primary energy savings of an ICE, an mGT and an mHAT. • We consider hourly heat and electricity demand profiles and 25 price scenarios. • Our analysis is carried out for two domestic users with distinctive demand profiles. • If

  3. Total kinetic energy in four global eddying ocean circulation models and over 5000 current meter records

    KAUST Repository

    Scott, Robert B.; Arbic, Brian K.; Chassignet, Eric P.; Coward, Andrew C.; Maltrud, Mathew; Merryfield, William J.; Srinivasan, Ashwanth; Varghese, Anson

    2010-01-01

    We compare the total kinetic energy (TKE) in four global eddying ocean circulation simulations with a global dataset of over 5000, quality controlled, moored current meter records. At individual mooring sites, there was considerable scatter between

  4. Mechanical energy expenditures and movement efficiency in full body reaching movements.

    Science.gov (United States)

    Sha, Daohang; France, Christopher R; Thomas, James S

    2010-02-01

    The effect of target location, speed, and handedness on the average total mechanical energy and movement efficiency is studied in 15 healthy subjects (7 males and 8 females with age 22.9 +/- 1.79 years old) performing full body reaching movements. The average total mechanical energy is measured as the time average of integration of joint power, potential energy, and kinetic energy respectively. Movement efficiency is calculated as the ratio of total kinetic energy to the total joint power and potential energy. Results show that speed and target location have significant effects on total mechanical energy and movement efficiency, but reaching hand only effects kinetic energy. From our findings we conclude that (1) efficiency in whole body reaching is dependent on whether the height of the body center of mass is raised or lowered during the task; (2) efficiency is increased as movement speed is increased, in part because of greater changes in potential energy; and (3) the CNS does not appear to use movement efficiency as a primary planning variable in full body reaching. It may be dependent on a combination of other factors or constraints.

  5. Operation of Grid -Connected Lithium-Ion Battery Energy Storage System for Primary Frequency Regulation

    DEFF Research Database (Denmark)

    Stroe, Daniel Loan; Knap, Vaclav; Swierczynski, Maciej Jozef

    2017-01-01

    Because of their characteristics, which have been continuously improved during the last years, Lithium ion batteries were proposed as an alternative viable solution to present fast-reacting conventional generating units to deliver the primary frequency regulation service. However, even though...... there are worldwide demonstration projects where energy storage systems based on Lithium-ion batteries are evaluated for such applications, the field experience is still very limited. In consequence, at present there are no very clear requirements on how the Lithium-ion battery energy storage systems should...... be operated while providing frequency regulation service and how the system has to re-establish its SOC once the frequency event has passed. Therefore, this paper aims to investigate the effect on the lifetime of the Lithium-ion batteries energy storage system of various strategies for re...

  6. Suggested Operation Grid-Connected Lithium-Ion Battery Energy Storage System for Primary Frequency Regulation

    DEFF Research Database (Denmark)

    Stroe, Daniel Ioan; Knap, Vaclav; Swierczynski, Maciej Jozef

    2015-01-01

    Because of their characteristics, which have been continuously improved during the last years, Lithium ion batteries were proposed as an alternative viable solution to present fast-reacting conventional generating units to deliver the primary frequency regulation service. However, even though...... there are worldwide demonstration projects where energy storage systems based on Lithium-ion batteries are evaluated for such applications, the field experience is still very limited. In consequence, at present there are no very clear requirements on how the Lithium-ion battery energy storage systems should...... be operated while providing frequency regulation service and how the system has to re-establish its SOC once the frequency event has passed. Therefore, this paper aims to investigate the effect on the lifetime of the Lithium-ion batteries energy storage system of various strategies for re...

  7. Some Environmental and Economic Aspects of Energy Saving Measures in Houses. An estimation model for total energy consumption and emissions to air from the Norwegian dwelling stock, and a life cycle assessment method for energy saving measures in houses

    Energy Technology Data Exchange (ETDEWEB)

    Myhre, L

    1995-12-01

    Motivated by the need to reduce the total energy consumption and the environmental load from society, this doctoral thesis discusses energy conservation measures on existing houses. Alternative additional thermal insulation measures are assessed using an interdisciplinary life cycle approach. The first task is to develop an interdisciplinary assessment method for building improvement measures, taking account of energy consumption, resource consumption, emissions to air of environmentally harmful gases, and economic costs during the entire life cycle of the building. The second task is to develop an estimation model for the total energy consumption and emissions to air of environmentally harmful gases from the dwelling stock of Norway. Finally, the third task is to assess the total energy saving potential and the total environmental benefits of energy saving measures in houses on a national level, including only life cycle analyses of additional thermal insulation measures on single houses. Chap 2 describes the dwelling stock in Norway. Chaps 3 and 4 present an estimation model for total energy consumption and emissions to air from the dwelling stock, and calculations using the model. Chaps 5 and 6 propose and use a calculation method for the assessment of additional thermal insulation measures, using a ``cradle-to-grave`` approach. Since hydroelectric power is the main energy source in this sector in Norway, estimated payback periods for emissions to air are long. But hydroelectric power saved in this sector may be used to obtain reduction in fossil fuel use in other sectors as discussed in Chap 7. Some of the topics discussed are further elaborated on in appendices. 107 refs., 39 figs, 88 tabs.

  8. Conceptual design of primary coolant purification system using cylindrical membrane for nuclear energy system base on HTGR

    International Nuclear Information System (INIS)

    Piping Supriatna

    2011-01-01

    The recent progress of reactor technology design for next generation reactor will be implemented on cogeneration reactor, which the aim of reactor operation not only for generating electrical energy, but also for other application like desalination, industrial manufacturing process, hydrogen production, Enhanced Oil Recovery (EOR), etc. The cogeneration reactor concept developed for generate energy effectively, efficiently and sustainable, which reserve of uranium and thorium nuclear fuel for cogeneration reactor is supply able for world energy demand until next thousand years. The cogeneration reactor produce temperature output higher than commonly Nuclear Power Plant (NPP), and need special Heat Exchanger with helium gas as coolant. In order to preserve heat transfer with high efficiency, constant purity of the gas must be maintained as well as possible, especially contamination from its impurities. In this research has been designed modeling and assessment of primary coolant gas purification system with purify and fill up helium gas continuously, by using Cylindrical Helium Splitting Membrane and helium gas inventory system. The result of flow rate helium assessment for the purification system is 0.844x10 -3 kg/sec, where helium flow rate of reactor primary coolant is 120 kg/sec. The result of study show that the Primary Coolant Gas Purification System is enable to be implemented on Cogeneration Reactor HTGR200C. (author)

  9. Control mechanisms for battery energy storage system performing primary frequency regulation and self-consumption optimization

    NARCIS (Netherlands)

    Pliatskas Stylianidis, A.

    2016-01-01

    This report contains the design of a model for the integration of a battery energy system in a household level and its use for primary frequency regulation and self-consumption optimization. The main goal of this project was to investigate what are the possible applications and the most suitable for

  10. Measurement of the photon-proton total cross section at a center-of-mass energy of 209 GeV at HERA

    International Nuclear Information System (INIS)

    Chekanov, S.; Derrick, M.; Krakauer, D.; Magill, S.; Musgrave, B.; Pellegrino, A.; Repond, J.; Yoshida, R.; Mattingly, M.C.K.; Antonioli, P.; Bari, G.; Basile, M.; Bellagamba, L.; Boscherini, D.; Bruni, A.; Bruni, G.; Cara Romeo, G.; Cifarelli, L.; Cindolo, F.; Contin, A.; Corradi, M.; De Pasquale, S.; Giusti, P.; Iacobucci, G.; Levi, G.; Margotti, A.; Massam, T.; Nania, R.; Palmonari, F.; Pesci, A.; Sartorelli, G.; Zichichi, A.; Aghuzumtsyan, G.; Bartsch, D.; Brock, I.; Crittenden, J.; Goers, S.; Hartmann, H.; Hilger, E.; Irrgang, P.; Jakob, H.-P.; Kappes, A.; Katz, U.F.; Kerger, R.; Kind, O.; Paul, E.; Rautenberg, J.; Renner, R.; Schnurbusch, H.; Stifutkin, A.; Tandler, J.; Voss, K.C.; Weber, A.; Wessoleck, H.; Bailey, D.S.; Brook, N.H.; Cole, J.E.; Foster, B.; Heath, G.P.; Heath, H.F.; Robins, S.; Rodrigues, E.; Scott, J.; Tapper, R.J.; Wing, M.; Capua, M.; Mastroberardino, A.; Schioppa, M.; Susinno, G.; Jeoung, H.Y.; Kim, J.Y.; Lee, J.H.; Lim, I.T.; Ma, K.J.; Pac, M.Y.; Caldwell, A.; Helbich, M.; Liu, X.; Mellado, B.; Paganis, S.; Schmidke, W.B.; Sciulli, F.; Chwastowski, J.; Eskreys, A.; Figiel, J.; Olkiewicz, K.; Przybycien, M.B.; Stopa, P.; Zawiejski, L.; Bednarek, B.; Grabowska-Bold, I.; Jelen, K.; Kisielewska, D.; Kowal, A.M.; Kowal, M.; Kowalski, T.; Mindur, B.; Przybycien, M.; Rulikowska-Zarebska, E.; Suszycki, L.; Szuba, D.; Szuba, J.; Kotanski, A.; Slominski, W.; Bauerdick, L.A.T.; Behrens, U.; Borras, K.; Chiochia, V.; Dannheim, D.; Desler, K.; Drews, G.; Fourletova, J.; Fox-Murphy, A.; Fricke, U.; Geiser, A.; Goebel, F.; Goettlicher, P.; Graciani, R.; Haas, T.; Hain, W.; Hartner, G.F.; Hillert, S.; Koetz, U.; Kowalski, H.; Labes, H.; Lelas, D.; Loehr, B.; Mankel, R.; Martens, J.; Martinez, M.; Moritz, M.; Notz, D.; Petrucci, M.C.; Polini, A.; Schneekloth, U.; Selonke, F.; Stonjek, S.; Surrow, B.; Whitmore, J.J.; Wichmann, R.; Wolf, G.; Youngman, C.; Zeuner, W.; Coldewey, C.; Lopez-Duran Viani, A.; Meyer, A.; Schlenstedt, S.; Barbagli, G.; Gallo, E.; Genta, C.; Pelfer, P.G.; Bamberger, A.; Benen, A.; Coppola, N.; Markun, P.; Raach, H.; Woelfle, S.; Bell, M.; Bussey, P.J.; Doyle, A.T.; Glasman, C.; Hanlon, S.; Lee, S.W.; Lupi, A.; McCance, G.J.; Saxon, D.H.; Skillicorn, I.O.; Bodmann, B.; Holm, U.; Salehi, H.; Wick, K.; Ziegler, A.; Ziegler, Ar.; Carli, T.; Gialas, I.; Klimek, K.; Lohrmann, E.; Milite, M.; Collins-Tooth, C.; Foudas, C.; Goncalo, R.; Long, K.R.; Metlica, F.; Miller, D.B.; Tapper, A.D.; Walker, R.; Cloth, P.; Filges, D.; Kuze, M.; Nagano, K.; Tokushuku, K.; Yamada, S.; Yamazaki, Y.; Barakbaev, A.N.; Boos, E.G.; Pokrovskiy, N.S.; Zhautykov, B.O.; Ahn, S.H.; Lee, S.B.; Park, S.K.; Lim, H.; Son, D.; Barreiro, F.; Garcia, G.; Gonzalez, O.; Labarga, L.; del Peso, J.; Redondo, I.; Terron, J.; Vazquez, M.; Barbi, M.; Bertolin, A.; Corriveau, F.; Ochs, A.; Padhi, S.; Stairs, D.G.; St-Laurent, M.; Tsurugai, T.; Antonov, A.; Bashkirov, V.; Danilov, P.; Dolgoshein, B.A.; Gladkov, D.; Sosnovtsev, V.; Suchkov, S.; Dementiev, R.K.; Ermolov, P.F.; Golubkov, Yu.A.; Katkov, I.I.; Khein, L.A.; Korotkova, N.A.; Korzhavina, I.A.; Kuzmin, V.A.; Levchenko, B.B.; Lukina, O.Yu.; Proskuryakov, A.S.; Shcheglova, L.M.; Solomin, A.N.; Vlasov, N.N.; Zotkin, S.A.; Bokel, C.; Engelen, J.; Grijpink, S.; Koffeman, E.; Kooijman, P.; Maddox, E.; Schagen, S.; Tassi, E.; Tiecke, H.; Tuning, N.; Velthuis, J.J.; Wiggers, L.; de Wolf, E.; Bruemmer, N.; Bylsma, B.; Durkin, L.S.; Gilmore, J.; Ginsburg, C.M.; Kim, C.L.; Ling, T.Y.; Boogert, S.; Cooper-Sarkar, A.M.; Devenish, R.C.E.; Ferrando, J.; Matsushita, T.; Rigby, M.; Ruske, O.; Sutton, M.R.; Walczak, R.; Brugnera, R.; Carlin, R.; Dal Corso, F.; Dusini, S.; Garfagnini, A.; Limentani, S.; Longhin, A.; Parenti, A.; Posocco, M.; Stanco, L.; Turcato, M.; Adamczyk, L.; Oh, B.Y.; Saull, P.R.B.; Iga, Y.; D'Agostini, G.; Marini, G.; Nigro, A.; Cormack, C.; Hart, J.C.; McCubbin, N.A.; Heusch, C.; Park, I.H.; Pavel, N.; Abramowicz, H.; Dagan, S.; Gabareen, A.; Kananov, S.; Kreisel, A.; Levy, A.; Abe, T.; Fusayasu, T.; Kohno, T.; Umemori, K.; Yamashita, T.; Hamatsu, R.; Hirose, T.; Inuzuka, M.; Kitamura, S.; Matsuzawa, K.; Nishimura, T.; Arneodo, M.; Cartiglia, N.; Cirio, R.; Costa, M.; Ferrero, M.I.; Maselli, S.; Monaco, V.; Peroni, C.; Ruspa, M.; Sacchi, R.; Solano, A.; Staiano, A.; Galea, R.; Koop, T.; Levman, G.M.; Martin, J.F.; Mirea, A.; Sabetfakhri, A.; Butterworth, J.M.; Gwenlan, C.; Hall-Wilton, R.; Hayes, M.E.; Heaphy, E.A.; Jones, T.W.; Lane, J.B.; Lightwood, M.S.; West, B.J.; Ciborowski, J.; Ciesielski, R.; Grzelak, G.; Nowak, R.J.; Pawlak, J.M.; Smalska, B.; Sztuk, J.; Tymieniecka, T.; Ukleja, A.; Ukleja, J.; Zakrzewski, J.A.; Zarnecki, A.F.; Adamus, M.; Plucinski, P.; Eisenberg, Y.; Gladilin, L.K.; Hochman, D.; Karshon, U.; Breitweg, J.; Chapin, D.; Cross, R.; Kcira, D.; Lammers, S.; Reeder, D.D.; Savin, A.A.; Smith, W.H.; Deshpande, A.; Dhawan, S.; Hughes, V.W.; Straub, P.B.; Bhadra, S.; Catterall, C.D.; Fourletov, S.; Menary, S.; Soares, M.; Standage, J.

    2002-01-01

    The photon-proton total cross section has been measured in the process e + p→e + γp→e + X with the ZEUS detector at HERA. Events were collected with photon virtuality Q 2 2 and average γp center-of-mass energy W γp =209 GeV in a dedicated run, designed to control systematic effects, with an integrated luminosity of 49 nb -1 . The measured total cross section is σ tot γp =174±1 (stat.)±13 (syst.) μb. The energy dependence of the cross section is compatible with parameterizations of high-energy pp and pp-bar data

  11. A panel data parametric frontier technique for measuring total-factor energy efficiency: An application to Japanese regions

    International Nuclear Information System (INIS)

    Honma, Satoshi; Hu, Jin-Li

    2014-01-01

    Using the stochastic frontier analysis model, we estimate TFEE (total-factor energy efficiency) scores for 47 regions across Japan during the years 1996–2008. We extend the cross-sectional stochastic frontier model proposed by Zhou et al. (2012) to panel data models and add environmental variables. The results provide not only the TFEE scores, in which statistical noise is taken into account, but also the determinants of inefficiency. The three stochastic TFEE scores are compared with a TFEE score derived using data envelopment analysis. The four TFEE scores are highly correlated with one another. For the inefficiency estimates, higher manufacturing industry shares and wholesale and retail trade shares correspond to lower TFEE scores. - Highlights: • This study estimates total-factor energy efficiency of Japanese regions using the stochastic frontier analysis model. • Determinants of inefficiency are also estimated. • The higher the manufacturing share and wholesale and retail trade share, the lower the energy efficiency

  12. Beverage Consumption Habits in Italian Population: Association with Total Water Intake and Energy Intake

    Directory of Open Access Journals (Sweden)

    Lorenza Mistura

    2016-10-01

    Full Text Available Background: The aim of this study was to investigate total water intake (TWI from water, beverages and foods among Italian adults and the elderly. Methods: Data of 2607 adults and the elderly, aged 18–75 years from the last national food consumption survey, INRAN-SCAI 2005-06, were used to evaluate the TWI. The INRAN-SCAI 2005-06 survey was conducted on a representative sample of 3323 individuals aged 0.1 to 97.7 years. A 3-day semi-structured diary was used for participants to record the consumption of all foods, beverages and nutritional supplements. Results: On average, TWI was 1.8 L for men and 1.7 L for women. More than 75% of women and 90% of men did not comply with the European Food Safety Authority (EFSA Adequate Intake. The contribution of beverages to the total energy intake (EI was 6% for the total sample. Water was the most consumed beverage, followed by alcoholic beverages for men and hot beverages for women. Conclusion: According to the present results, adults and elderly Italians do not reach the adequate intake for water as suggested by the EFSA and by the national reference level of nutrient and energy intake. Data on water consumption should also be analyzed in single socio-demographic groups in order to identify sub-groups of the population that need more attention and to plan more targeted interventions.

  13. Totally implantable total artificial heart and ventricular assist device with multipurpose miniature electromechanical energy system.

    Science.gov (United States)

    Takatani, S; Orime, Y; Tasai, K; Ohara, Y; Naito, K; Mizuguchi, K; Makinouchi, K; Damm, G; Glueck, J; Ling, J

    1994-01-01

    A multipurpose miniature electromechanical energy system has been developed to yield a compact, efficient, durable, and biocompatible total artificial heart (TAH) and ventricular assist device (VAD). Associated controller-driver electronics were recently miniaturized and converted into hybrid circuits. The hybrid controller consists of a microprocessor and controller, motor driver, Hall sensor, and commutation circuit hybrids. The sizing study demonstrated that all these components can be incorporated in the pumping unit of the TAH and VAD, particularly in the centerpiece of the TAH and the motor housing of the VAD. Both TAH and VAD pumping units will start when their power line is connected to either the internal power pack or the external battery unit. As a redundant driving and diagnostic port, an emergency port was newly added and will be placed in subcutaneous location. In case of system failure, the skin will be cut down, and an external motor drive or a pneumatic driver will be connected to this port to run the TAH. This will minimize the circulatory arrest time. Overall efficiency of the TAH without the transcutaneous energy transmission system was 14-18% to deliver pump outputs of 4-9 L/min against the right and left afterload pressures of 25 and 100 mm Hg. The internal power requirement ranged from 6 to 13 W. The rechargeable batteries such as NiCd or NiMH with 1 AH capacity can run the TAH for 30-45 min. The external power requirement, when TETS efficiency of 75% was assumed, ranged from 8 to 18 W. The accelerated endurance test in the 42 degrees C saline bath demonstrated stable performance over 4 months. Long-term endurance and chronic animal studies will continue toward a system with 5 years durability by the year 2000.

  14. Fracture of Fully-coated Femoral Stem after Primary Total Hip Arthroplasty for Nonunion of Intertrochanteric Fracture: A Case Report.

    Science.gov (United States)

    Chun, Young Soo; Juh, Hyung Suk; Cho, Yoon Je; Rhyu, Kee Hyung

    2015-09-01

    Femoral stem fracture is an uncommon reason for the failure of total hip arthroplasty, with only 16 cases of fully coated stem fractures reported to date. Here we report a case in which a fully coated primary femoral stem fracture occurred after conversion to total hip arthroplasty for the non-union of an intertrochanteric fracture of the femur. Metallurgic evaluation of the etiology and mechanism revealed that the fracture was initiated by fatigue-related failure and completed by ductile failure on the posterior side of the fracture. Considering the recent trend of treating an intertrochanteric fracture with hip arthroplasty, possible stem failure should be considered, since most patients will have at least one of the known risk factors for stem fracture.

  15. Predictors of fecal incontinence and related quality of life after a total mesorectal excision with primary anastomosis for patients with rectal cancer

    NARCIS (Netherlands)

    Walma, Marieke S; Kornmann, Verena N N; Boerma, Djamila; de Roos, Marnix A J; van Westreenen, Henderik L

    PURPOSE: After total mesorectal excision (TME) with primary anastomosis for patients with rectal cancer, the quality of life (QoL) may be decreased due to fecal incontinence. This study aimed to identify predictors of fecal incontinence and related QoL. METHODS: Patients who underwent TME with

  16. Extraction of topographic and material contrasts on surfaces from SEM images obtained by energy filtering detection with low-energy primary electrons

    International Nuclear Information System (INIS)

    Nagoshi, Masayasu; Aoyama, Tomohiro; Sato, Kaoru

    2013-01-01

    Secondary electron microscope (SEM) images have been obtained for practical materials using low primary electron energies and an in-lens type annular detector with changing negative bias voltage supplied to a grid placed in front of the detector. The kinetic-energy distribution of the detected electrons was evaluated by the gradient of the bias-energy dependence of the brightness of the images. This is divided into mainly two parts at about 500 V, high and low brightness in the low- and high-energy regions, respectively and shows difference among the surface regions having different composition and topography. The combination of the negative grid bias and the pixel-by-pixel image subtraction provides the band-pass filtered images and extracts the material and topographic information of the specimen surfaces. -- Highlights: ► Scanning electron (SE) images contain many kind of information on material surfaces. ► We investigate energy-filtered SE images for practical materials. ► The brightness of the images is divided into two parts by the bias voltage. ► Topographic and material contrasts are extracted by subtracting the filtered images.

  17. Analysis on Price Elasticity of Energy Demand in East Asia: Empirical Evidence and Policy Implications for ASEAN and East Asia

    OpenAIRE

    Han PHOUMIN; Shigeru KIMURA

    2014-01-01

    This study uses time series data of selected ASEAN and East Asia countries to investigate the patterns of price and income elasticity of energy demand. Applying a dynamic log-linear energy demand model, both short-run and long-run price and income elasticities were estimated by country. The study uses three types of dependent variable “energy demand” such as total primary energy consumption (TPES), total final energy consumption (TFEC) and total final oil consumption (TFOC) to regress on its ...

  18. Energy memento 2014

    International Nuclear Information System (INIS)

    2014-01-01

    This memento about energy provides a series of tables with figures relative to energy resources and uses in France, in the European Union and in the rest of the world. Content: 1 - resources, consumption and production: Main energy units, Main power units, Anglo-saxon and metric units conversion, Common units for uranium, Conversion table for uranium compounds, Lower calorific value for coals, Basic data about hydrogen, France: primary energy accountancy, Energy equivalence for natural Uranium, Energy equivalence for fossil fuels; 2 - resources: World - proved reserves of fossil fuels per geographical area at end 2013, World - most important uranium reserves, Renewable installed world capacity evolution, Europe - installed capacity for offshore wind power in the EU countries, Europe - electricity production and installed capacity from wind and photovoltaic in the EU, 3 - Consumption: Scenario of evolution of world population, World - general data for 2012, World - total primary energy supply, World - reference scenario for primary energy supply, World - final consumption of energy for 2012, World - reference scenario for final consumption of energy, Europe - general data for 2012, Europe - bio-fuel consumption for transport in the European Union in 2013, Electricity consumption per head, Final energy consumption per GDP unit, France - primary energy consumption (corrected for climate) by energy, France: final energy consumption (corrected for climate) by energy, France - final energy consumption (corrected for climate) by sector, France - two retained scenarios in the DNTE context (National debate on energetic transition), France - electricity balances, France - energy balance for 2013; 4 - Production: World - 2011 electricity installed capacities, Electricity generation from nuclear power plants by country at the end of 2013, World - electricity generation by fuel for 2012, World - electricity generation, World - reference scenario for electricity generation

  19. Improvement in quality of lifesix months after primary total hip arthroplasty in a Pakistani population.

    Science.gov (United States)

    Zubairi, Akbar Jaleel; Bin Mahmood, Syed Usman; Ali, Moiz; Noordin, Shahryar

    2016-10-01

    This prospective, cohort study was carried out to assess the improvement in quality of life of patients undergoing elective primary total hip arthroplasty (THA). It was conducted at the orthopaedic department of the Aga Khan University Hospital, Karachi, from June 2014 to May 2015, and comprised patients who had undergone THA. A total of 89 patients having a mean age of 41.5±12.0 years with a baseline core outcomes measure index (COMI)-hip score of > 3.5 were included. A decrease in COMI-hip score by >3 points six months post-operatively was considered improvement in quality of life. Patient satisfaction with restriction to squatting was assessed separately. The mean reduction in COMI-hip was 4.9±1.3 with 83(93%) patients experiencing significant improvement in quality of life. Age >50 years and American Society of Anaesthesiologists (ASA) level >III was significantly associated with no improvement in quality of life. Most patients were satisfied with their disability to squat irrespective of COMI-hip score. THA was found to be associated with significant improvement in quality of life and COMI-hip score was applicable in our population despite its inability to assess disability with restriction in squatting.

  20. Low energy positron interactions with uracil—Total scattering, positronium formation, and differential elastic scattering cross sections

    Energy Technology Data Exchange (ETDEWEB)

    Anderson, E. K.; Boadle, R. A.; Machacek, J. R.; Makochekanwa, C.; Sullivan, J. P. [ARC Centre for Antimatter-Matter Studies, Research School of Physics and Engineering, The Australian National University, Canberra 0200 (Australia); Chiari, L. [ARC Centre for Antimatter-Matter Studies, Flinders University, GPO Box 2100, Adelaide, 5001 SA (Australia); Buckman, S. J., E-mail: Stephen.buckman@anu.edu.au [ARC Centre for Antimatter-Matter Studies, Research School of Physics and Engineering, The Australian National University, Canberra 0200 (Australia); Institute of Mathematical Sciences, University of Malaya, Kuala Lumpur (Malaysia); Brunger, M. J. [ARC Centre for Antimatter-Matter Studies, Flinders University, GPO Box 2100, Adelaide, 5001 SA (Australia); Institute of Mathematical Sciences, University of Malaya, Kuala Lumpur (Malaysia); Garcia, G. [Instituto de Fısica Fundamental, Consejo Superior de Investigationes Cientıficas (CSIC), Serrano 113-bis, E-28006 Madrid (Spain); Blanco, F. [Departamento de Fısica Atomica, Molecular y Nuclear, Universidad Complutense de Madrid, E-28040 Madrid (Spain); Ingolfsson, O. [Department of Chemistry, Science Institute, University of Iceland, Reykjavík 107 (Iceland)

    2014-07-21

    Measurements of the grand total and total positronium formation cross sections for positron scattering from uracil have been performed for energies between 1 and 180 eV, using a trap-based beam apparatus. Angular, quasi-elastic differential cross section measurements at 1, 3, 5, 10, and 20 eV are also presented and discussed. These measurements are compared to existing experimental results and theoretical calculations, including our own calculations using a variant of the independent atom approach.

  1. Global energy futures and human development: a framework for analysis

    International Nuclear Information System (INIS)

    Pasternak, A.D.

    2001-01-01

    This paper explores the relationship between measures of human well-being and consumption of energy and electricity. A correlation is shown between the United Nations Human Development Index (HDI) and annual per- capita electricity consumption for 60 populous countries comprising 90% of the world population. In this correlation, HDI reaches a maximum value when electricity consumption is about 4,000 kWh per person per year, well below consumption levels for most developed countries but also well above the level for developing countries. The correlation with electricity use is better than with total primary energy use. Global electricity consumption associated with a ''Human Development Scenario'' is estimated by adding to U.S. Department of Energy projections for the year 2020 increments of additional electricity consumption sufficient to reach 4,000 kWh per capita on a country-by-country basis. A roughly constant ratio of primary energy consumption to electric energy consumption is observed for countries with high levels of electricity use, and this ratio is used to estimate global primary energy consumption in the Human Development Scenario. The Human Development Scenario implies significantly greater global consumption of electricity and primary energy than do projections for 2020 by the DOE and others. (author)

  2. Global energy futures and human development: a framework for analysis

    Energy Technology Data Exchange (ETDEWEB)

    Pasternak, A.D. [Lawrence Livermore National Lab., CA (United States)

    2001-07-01

    This paper explores the relationship between measures of human well-being and consumption of energy and electricity. A correlation is shown between the United Nations Human Development Index (HDI) and annual per- capita electricity consumption for 60 populous countries comprising 90% of the world population. In this correlation, HDI reaches a maximum value when electricity consumption is about 4,000 kWh per person per year, well below consumption levels for most developed countries but also well above the level for developing countries. The correlation with electricity use is better than with total primary energy use. Global electricity consumption associated with a ''Human Development Scenario'' is estimated by adding to U.S. Department of Energy projections for the year 2020 increments of additional electricity consumption sufficient to reach 4,000 kWh per capita on a country-by-country basis. A roughly constant ratio of primary energy consumption to electric energy consumption is observed for countries with high levels of electricity use, and this ratio is used to estimate global primary energy consumption in the Human Development Scenario. The Human Development Scenario implies significantly greater global consumption of electricity and primary energy than do projections for 2020 by the DOE and others. (author)

  3. Projection of primary energy in electricity generation with evaluation of demand and supply of energy in the medium-term horizon (2020), long-term (2035) and very long term (2060)

    International Nuclear Information System (INIS)

    Mafra, Olga Y.; Alvim, Carlos Feu; Eidelman, Frida; Guimaraes, Leonam dos Santos

    2013-01-01

    The Global Energy demand and the participation of electricity in scenarios of medium (2020), long (2035) and very long (2060) terms are estimated. It is also evaluated the share of different primary energies in electricity generation and their availability in the country. Three economic scenarios were considered and different hypothesis regarding the participation of nuclear energy were analyzed. (author)

  4. Test of the universal rise of hadronic total cross sections at super-high energies

    International Nuclear Information System (INIS)

    Ishida, Muneyuki; Igi, Keiji

    2007-01-01

    The increase of the total cross sections at very high energies described by log 2 (s/s 0 ) appears to be confirmed. In the analysis of the COMPETE collaboration in the Particle Data Group (2006), the Blog 2 (s/s 0 ) was assumed to extend the universal rise of all the total hadronic cross sections to reduce the number of adjustable parameters. We test if the assumption on the universality of B is justified, through investigation of the values of B for π ± p(K ± p) and pp,pp scatterings. We search for the simultaneous best fit to the σ tot and ρ ratios, using a constraint from the FESR of the P' type for π -+ p scatterings and constraints that are free from the unphysical regions for the pp, pp and K ± p scatterings. By including rich information of the low-energy scattering data owing to the use of FESR, the errors of the B parameters decrease especially for πp. The resulting value of B pp is consistent with B πp within two standard deviations, which appears to support the universality hypothesis. (orig.)

  5. Structures in the primary spectrum

    International Nuclear Information System (INIS)

    Kempa, J.; Knurenko, S.P.; Malecki, R.

    2009-01-01

    Structures in the energy spectrum of primary cosmic rays at the 'knee' region and for energies higher than 1 EeV are obtained through studying extensive air showers (EAS). The main problem of the research is the fact that we work in the ranges of highly fluctuating parameters used to obtain the primary energy spectrum. In this paper the log-normal distribution for the error function has been used in convolution with the power spectrum to explain the Yakutsk experimental data. Similar results have been obtained for the gamma distribution as the error function. Using the power law primary spectrum in the energy region around 10 19 eV we will argue that the primary Yakutsk spectrum is overestimated. In the best case this overestimation is not less than 42%.

  6. Electromagnetic Compatibility of Transcutaneous Energy Transmission Systemfor Totally Implantable Artificial Heart

    Science.gov (United States)

    Shiba, Kenji; Koshiji, Kohji

    Transcutaneous Energy Transmission (TET) is one way of providing the energy needed to power a totally implantable artificial heart (TIAH). In the present study, an externally coupled TET system was implanted in a prototype human phantom to evaluate emission and immunity. In the emission evaluation, measurements were conducted based on CISPR Pub.11 and VDE 0871 standards, while immunity tests were based on the standards of the IEC 61000-4 series. The magnetic field of the radiated emission was measured using a loop antenna. At 0.1[MHz], we found the greatest magnetic field of 47.8 [dBμA/m], somewhat less than CISPR’s upper limit of 54 [dBμA/m]. For the conducted emission, by installing a noise filter and ferrite beads in the input section of the DC-power supply, conducted emission could be kept within the allowable limits of CISPR Pub.11 and VDE 0871. Finally, the immunity tests against radiated and conducted emission, electrostatic discharge and voltage fluctuation proved that the prototype could withstand the maximum level of disturbance. These results confirmed that the TET system implanted in a human phantom could, through modification, meet the emission and immunity standards.

  7. Scenario analysis of energy-based low-carbon development in China.

    Science.gov (United States)

    Zhou, Yun; Hao, Fanghua; Meng, Wei; Fu, Jiafeng

    2014-08-01

    China's increasing energy consumption and coal-dominant energy structure have contributed not only to severe environmental pollution, but also to global climate change. This article begins with a brief review of China's primary energy use and associated environmental problems and health risks. To analyze the potential of China's transition to low-carbon development, three scenarios are constructed to simulate energy demand and CO₂ emission trends in China up to 2050 by using the Long-range Energy Alternatives Planning System (LEAP) model. Simulation results show that with the assumption of an average annual Gross Domestic Product (GDP) growth rate of 6.45%, total primary energy demand is expected to increase by 63.4%, 48.8% and 12.2% under the Business as Usual (BaU), Carbon Reduction (CR) and Integrated Low Carbon Economy (ILCE) scenarios in 2050 from the 2009 levels. Total energy-related CO₂ emissions will increase from 6.7 billiontons in 2009 to 9.5, 11, 11.6 and 11.2 billiontons; 8.2, 9.2, 9.6 and 9 billiontons; 7.1, 7.4, 7.2 and 6.4 billiontons in 2020, 2030, 2040 and 2050 under the BaU, CR and ILCE scenarios, respectively. Total CO₂ emission will drop by 19.6% and 42.9% under the CR and ILCE scenarios in 2050, compared with the BaU scenario. To realize a substantial cut in energy consumption and carbon emissions, China needs to make a long-term low-carbon development strategy targeting further improvement of energy efficiency, optimization of energy structure, deployment of clean coal technology and use of market-based economic instruments like energy/carbon taxation. Copyright © 2014. Published by Elsevier B.V.

  8. Energy implications of mechanical and mechanical-biological treatment compared to direct waste-to-energy.

    Science.gov (United States)

    Cimpan, Ciprian; Wenzel, Henrik

    2013-07-01

    Primary energy savings potential is used to compare five residual municipal solid waste treatment systems, including configurations with mechanical (MT) and mechanical-biological (MBT) pre-treatment, which produce waste-derived fuels (RDF and SRF), biogas and/or recover additional materials for recycling, alongside a system based on conventional mass burn waste-to-energy and ash treatment. To examine the magnitude of potential savings we consider two energy efficiency levels (state-of-the-art and best available technology), the inclusion/exclusion of heat recovery (CHP vs. PP) and three different background end-use energy production systems (coal condensing electricity and natural gas heat, Nordic electricity mix and natural gas heat, and coal CHP energy quality allocation). The systems achieved net primary energy savings in a range between 34 and 140 MJprimary/100 MJinput waste, in the different scenario settings. The energy footprint of transportation needs, pre-treatment and reprocessing of recyclable materials was 3-9.5%, 1-18% and 1-8% respectively, relative to total energy savings. Mass combustion WtE achieved the highest savings in scenarios with CHP production, nonetheless, MBT-based systems had similarly high performance if SRF streams were co-combusted with coal. When RDF and SRF was only used in dedicated WtE plants, MBT-based systems totalled lower savings due to inherent system losses and additional energy costs. In scenarios without heat recovery, the biodrying MBS-based system achieved the highest savings, on the condition of SRF co-combustion. As a sensitivity scenario, alternative utilisation of SRF in cement kilns was modelled. It supported similar or higher net savings for all pre-treatment systems compared to mass combustion WtE, except when WtE CHP was possible in the first two background energy scenarios. Recovery of plastics for recycling before energy recovery increased net energy savings in most scenario variations, over those of full

  9. Fast calculation of molecular total energy with ABEEMσπ/MM method – For some series of organic molecules and peptides

    International Nuclear Information System (INIS)

    Yang, Zhong-Zhi; Lin, Xiao-Ting; Zhao, Dong-Xia

    2016-01-01

    Highlights: • ABEEMσπ/MM method can be used to fast and accurately calculate the molecular total energy. • The energy obtained by ABEEMσπ/MM is in fair agreement with those from MP2/6-311++G(d, p). • ABEEMσπ charge can represent the anisotropy of the partial atomic charge. - Abstract: A new ABEEMσπ/MM method for fast calculation of molecular total energy is established by combining ABEEMσπ model with force field representation, where ABEEMσπ is the atom-bond electronegativity equalization model at the σπ level. The calibrated parameters are suitable and transferable. This paper demonstrates that the total molecular energies for series of alcohols, aldehydes, carboxylic acids and peptides calculated by ABEEMσπ/MM method are in fair agreement with those obtained from calculations of ab initio MP2/6-311++G(d, p) method with mean absolute deviation (MAD) being 1.45 kcal/mol and their linear correlation coefficients being 1.0000. Thus it opens good prospects for wide applications to chemical and biological systems.

  10. Measurement of antiproton-proton elastic scattering and total cross section at a centre-of-mass energy of 546 GeV

    International Nuclear Information System (INIS)

    Swol, R.W. van.

    1985-01-01

    The transformation of the CERN Super Proton Synchrotron (SPS) from a fixed target machine into a colliding beam facility allowed the study of antiproton-proton scattering at a centre-of-mass (CM) energy of 546 GeV. This thesis describes the measurement of antiproton-proton elastic scattering and the antiproton-proton total cross section, sigmasub(tot)(anti pp), at the CERN anti pp Collider. The aim of the experiment is to establish the considerable rise with energy of the total cross section, which was predicted after the discovery of rising proton-proton total cross sections at the CERN Intersecting Storage Rings (ISR), covering an energy range of 20-60 GeV. The experimental method used for measuring sigmasub(tot)(anti pp) with an accuracy of 1-2% consists of the simultaneous measurement of both the elastic scattering event rate at small scattering angles and the inelastic interaction rate. Using the optical theorem, the total and the elastic cross sections can then be obtained without a determination of the machine luminosity. (Auth.)

  11. Primary Care Physician and Patient Perceptions of Reimbursement for Total Knee and Hip Replacement.

    Science.gov (United States)

    Wiznia, Daniel H; Kim, Chang-Yeon; Wang, Yuexin; Swami, Nishwant; Pelker, Richard R

    2016-07-01

    The opinions of nonspecialists and patients will be important to determining reimbursements for specialists such as orthopedic surgeons. In addition, primary care physician (PCP) perceptions of reimbursements may affect utilization of orthopedic services. We distributed a web-based survey to PCPs, asking how much they believed orthopedic surgeons were reimbursed for total hip arthroplasty (THA) and total knee arthroplasty (TKA). We also proctored a paper-based survey to postoperative patients, asking how much orthopedic surgeons should be reimbursed. There was a significant difference between perceived and actual reimbursement values for THA and TKA. Hospital-affiliated PCPs estimated higher reimbursements for both THA ($1657 vs $838, P < .0001 for Medicaid and $2246 vs $1515, P = .018 for Medicare) and TKA ($1260 vs $903, P = .052 for Medicaid and $2022 vs $1514, P = .049 for Medicare). Similarly, larger practices estimated higher reimbursements for both THA ($1861 vs $838, P < .0001 for Medicaid and $2635 vs $1515, P = .004 for Medicare) and TKA ($1583 vs $903, P = .005 for Medicaid and $2380 vs $1514, P = .011 for Medicare). Compared to PCPs, patients estimated that orthopedic surgeons should be paid 4 times higher for both THA ($9787 vs $2235, P < .0001) and TKA ($9088 vs $2134, P < .0001). PCPs believe that reimbursements for orthopedic procedures are higher than actual values. The effect that these perceptions will have on efforts at cost reform and utilization of orthopedic services requires further study. Copyright © 2016 Elsevier Inc. All rights reserved.

  12. The balance of kinetic and total energy simulated by the OSU two-level atmospheric general circulation model for January and July

    Science.gov (United States)

    Wang, J.-T.; Gates, W. L.; Kim, J.-W.

    1984-01-01

    A three-year simulation which prescribes seasonally varying solar radiation and sea surface temperature is the basis of the present study of the horizontal structure of the balances of kinetic and total energy simulated by Oregon State University's two-level atmospheric general circulation model. Mechanisms responsible for the local energy changes are identified, and the energy balance requirement's fulfilment is examined. In January, the vertical integral of the total energy shows large amounts of external heating over the North Pacific and Atlantic, together with cooling over most of the land area of the Northern Hemisphere. In July, an overall seasonal reversal is found. Both seasons are also characterized by strong energy flux divergence in the tropics, in association with the poleward transport of heat and momentum.

  13. New energy vision in Iide Town (Yamagata Prefecture), town of 'circulation type energy' that connects nature, people and life together; Iidecho chiiki shin energy vision. Shizen hito kurashi wo tsunageru 'junkangata energy' no machi

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-02-01

    With an aim of regenerating a sustainable circulation type society, a new energy introduction plan was established that saves energy and utilizes reproducible resources. The plan lasts until 2010 with the target of the new energy introduction quantity in 2010 to reach 3.1% of the total primary energy supply quantity. The activity achievements were put into order by the following seven items: 1) summary of Iide Town, 2) types and utilization methods of new energies, 3) trends of energy demand in Iide Town, 4) possibility of utilizing new energies in Iide Town, 5) basic conception for introducing new energies, 6) systems of new energy vision, and 7) what is to be done with emphasis for the time being. In Item 3, considerations were given on the energy using modes and demand quantity. Fields of the object include public facilities, general households, and agricultural production. The using modes cover heat, electric power, and automotive use. The total demand was calculated as 145,891 Gcal/year, divided into the heat utilization at 50.7%, the electric power at 8.8%, and the automotive use at 40.6%. (NEDO)

  14. Total, partial and differential ionization cross sections in proton-hydrogen collisions at low energy

    Energy Technology Data Exchange (ETDEWEB)

    Zou, Shiyang [Graduate University for Advanced Studies, School of Mathematical and Physical Science, Toki, Gifu (Japan); Pichl, Lukas [University of Aizu, Foundation of Computer Science Laboratory, Aizuwakamatsu, Fukushima (Japan); Kimura, Mineo [Yamaguchi Univ., Graduate School of Science and Engineering, Ube, Yamaguchi (Japan); Kato, Takako [National Inst. for Fusion Science, Toki, Gifu (Japan)

    2003-01-01

    Single-differential, partial and total ionization cross sections for the proton-hydrogen collision system at low energy range (0.1-10 keV/amu) are determined by using the electron translation factor corrected molecular-orbital close-coupling method. Full convergence of ionization cross sections as a function of H{sub 2}{sup +} molecular basis size is achieved by including up to 10 bound states, and 11 continuum partial waves. The present cross sections are in an excellent agreement with the recent experiments of Shah et al., but decrease more rapidly than the cross sections measured by Pieksma et al. with decreasing energy. The calculated cross section data are included in this report. (author)

  15. Antenna entropy in plant photosystems does not reduce the free energy for primary charge separation.

    Science.gov (United States)

    Jennings, Robert C; Zucchelli, Giuseppe

    2014-12-01

    We have investigated the concept of the so-called "antenna entropy" of higher plant photosystems. Several interesting points emerge: 1. In the case of a photosystemwhich harbours an excited state, the “antenna entropy” is equivalent to the configurational (mixing) entropy of a thermodynamic canonical ensemble. The energy associated with this parameter has been calculated for a hypothetical isoenergetic photosystem, photosystem I and photosystem II, and comes out in the range of 3.5 - 8% of the photon energy considering 680 nm. 2. The “antenna entropy” seems to be a rather unique thermodynamic phenomenon, in as much as it does not modify the free energy available for primary photochemistry, as has been previously suggested. 3. It is underlined that this configurational (mixing) entropy, unlike heat dispersal in a thermal system, does not involve energy dilution. This points out an important difference between thermal and electronic energy dispersal. Copyright © 2014 Elsevier B.V. All rights reserved.

  16. Impurities in semiconductors: total energy and infrared absorption calculations

    International Nuclear Information System (INIS)

    Yndurain, F.

    1987-01-01

    A new method to calculate the electronic structure of infinite nonperiodic system is discussed. The calculations are performed using atomic pseudopotentials and a basis of atomic Gaussiam wave functions. The Hartree-Fock self consistent equations are solved in the cluster-Bethe lattice system. Electron correlation is partially included in second order pertubation approximation. The formalism is applied to hydrogenated amorphous silicon. Total energy calculations of finite clusters of silicon atom in the presence of impurities, are also presented. The results show how atomic oxygen breaks the covalent silicon silicon bond forming a local configuration similar to that of SiO 2 . Calculations of the infrared absorption due to the presence of atomic oxygen in cristalline silicon are presented. The Born Hamiltonian to calculate the vibrational modes of the system and a simplied model to describe the infrared absorption mechanism are used. The interstitial and the the substitutional cases are considered and analysed. The position of the main infrared absorption peak, their intensities and their isotope shifts are calculated. The results are satisfactory agreement with the available data. (author) [pt

  17. A comparative analysis of energy and CO2 taxes on the primary energy mix for electricity generation

    International Nuclear Information System (INIS)

    Voorspools, Kris; Peersman, Inneke; D'haeseleer, William

    2005-01-01

    In many countries, economies are moving towards internalization of external costs of greenhouse-gas (GHG) emissions. This can best be achieved by either imposing additional taxes or by using an emission-permit-trading scheme. The electricity sector is under scrutiny in the allocation of emission-reduction objectives, not only because it is a large homogeneous target, but also because of the obvious emission-reduction potential by decreasing power generation based on carbon-intensive fuels. In this paper, we discuss the impact of a primary-energy tax and a CO 2 tax on the dispatching strategy in power generation. In a case study for the Belgian power-generating context, several tax levels are investigated and the impact on the optimal dispatch is simulated. The impact of the taxes on the power demand or on the investment strategies is not considered. As a conclusion, we find that a CO 2 tax is more effective than a primary-energy tax. Both taxes accomplish an increased generation efficiency in the form of a promotion of combined-cycle gas-fired units over coal-fired units. The CO 2 tax adds an incentive for fuel switching which can be achieved by altering the merit order of power plants or by switching to a fuel with a lower carbon content within a plant. For the CO 2 tax, 13 euros/ton CO 2 is withheld as the optimal value which results in an emission reduction of 13% of the electricity-related GHG emissions in the Belgian power context of 2000. A tax higher than 13 euros/ton CO 2 does not contribute to the further reduction of GHGs. (Author)

  18. 2002 energy statistics

    International Nuclear Information System (INIS)

    2003-01-01

    This report has 12 chapters. The first chapter includes world energy reserves, the second chapter is about world primary energy production and consumption condition. Other chapters include; world energy prices, energy reserves in Turkey, Turkey primary energy production and consumption condition, Turkey energy balance tables, Turkey primary energy reserves production, consumption, imports and exports conditions, sectoral energy consumptions, Turkey secondary electricity plants, Turkey energy investments, Turkey energy prices.This report gives world and Turkey statistics on energy

  19. Total reaction cross section of silicon induced by 4He in the energy range 3-10 MeV/u

    International Nuclear Information System (INIS)

    Ugryumov, V.Yu.; Kuznetsov, I.V.; Kalpakchieva, R.

    2003-01-01

    The energy dependence of total reaction cross section for α-particles on nat Si has been directly and accurately measured by the transmission method. These data show that σ R has different energy dependence from theoretical predictions at low energies. The σ R corrections due to inelastic scattering to the first excited state were made by integrating corresponding angular distributions

  20. Total Reaction Cross Section of Silicon Induced by ^{4}He in the Energy Range 3-10 MeV/u

    CERN Document Server

    Ugryumov, V Yu; Basybekov, K B; Bialkowski, E; Budzanowski, A; Duysebaev, A D; Duysebaev, B A; Zholdybaev, T K; Ismailov, K M; Kadyrzhanov, K K; Kalpakchieva, R; Kugler, A; Kukhtina, I N; Kushniruk, V F; Kuterbekov, K A; Mukhambetzhan, A; Penionzhkevich, Yu E; Sadykov, B M; Skwirczynska, I; Sobolev, Yu G

    2003-01-01

    The energy dependence of total reaction cross section for alpha-particles on ^{nat}Si has been directly and accurately measured by the transmission method. These data show that sigma_R has different energy dependence from theoretical predictions at low energies. The sigma_R corrections due to inelastic scattering to the first excited state were made by integrating corresponding angular distributions.

  1. Energy efficiency and economic feasibility of CCHP driven by stirling engine

    International Nuclear Information System (INIS)

    Kong, X.Q.; Wang, R.Z.; Huang, X.H.

    2004-01-01

    This paper deals with the problem of energy efficiency evaluation and economic feasibility analysis of a small scale trigeneration system for combined cooling, heating and power generation (CCHP) with an available Stirling engine. Trigeneration systems have a large potential of energy saving and economical efficiency. The decisive values for energetic efficiency evaluation of such systems are the primary energy rate and comparative primary energy saving (Δq), while the economic feasibility analysis of such systems relates the avoided cost, the total annual saving and payback period. The investigation calculates and compares the energy saving and economic efficiency of trigeneration system with Stirling engine against contemporary conventional independent cooling, heating and power, showing that a CCHP system saves fuel resources and has the assurance of economic benefits

  2. Annual Energy Review 2011

    Energy Technology Data Exchange (ETDEWEB)

    Fichman, Barbara T. [USDOE Energy Information Administration (EIA), Washington, DC (United States)

    2012-09-01

    The Annual Energy Review (AER) is the U.S. Energy Information Administration's (EIA) primary report of annual historical energy statistics. For many series, data begin with the year 1949. Included are statistics on total energy production, consumption, trade, and energy prices; overviews of petroleum, natural gas, coal, electricity, nuclear energy, and renewable energy; financial and environment indicators; and data unit conversions. Publication of this report is required under Public Law 95–91 (Department of Energy Organization Act), Section 205(c), and is in keeping with responsibilities given to the EIA under Section 205(a)(2), which states: “The Administrator shall be responsible for carrying out a central, comprehensive, and unified energy data and information program which will collect, evaluate, assemble, analyze, and disseminate data and information....” The AER is intended for use by Members of Congress, Federal and State agencies, energy analysts, and the general public. EIA welcomes suggestions from readers regarding the content of the AER and other EIA publications.

  3. Utilisation of total solar radiation energy in the photosynthetic production of radish, red beet and bean

    Directory of Open Access Journals (Sweden)

    Wiesław Nowakowski

    2014-01-01

    Full Text Available Utilisation of total solar radiation energy in the photosynthetic production of radish, red beet and bean is expressed as per cent of solar radiation accumulated in the carbon of -the dry mass per 1 cm2 of the assimilation surface area. Utilisation of this energy ranges from 2.6 to 8.4 per cent in radish, from 1.7 to 7.5 per cent in beet and from 1.9 to 4.9 per cent in bean.

  4. Manifestation of jet quenching in differential distributions of the total transverse energy in nucleus-nucleus collisions

    International Nuclear Information System (INIS)

    Savina, M.V.; Shmatov, S.V.; Slavin, N.V.; Zarubin, P.I.

    1998-01-01

    In the framework of the HIJING model, global characteristics of nucleus-nucleus collisions are studied for a Large Hadron Collider (LHC) energy scale. An interesting model prediction is the presence of a central bump over a pseudorapidity plateau of a total transverse energy distribution. The bump is induced by a jet quenching effect in a dense nuclear matter. It is shown that a wide acceptance calorimeter with a pseudorapidity coverage -5<η<5 allows one to obtain experimental confirmation of such an effect

  5. Mid-South solar total energy: institutional analysis. Final report, May 1, 1978-December 31, 1979

    Energy Technology Data Exchange (ETDEWEB)

    Powe, R.E.; Carley, C.T.; Forbes, R.E.; Johnson, L.R.; Stiffler, A.K.; Hodge, B.K.; Bouchillon, C.W.

    1979-01-01

    A comprehensive survey was undertaken to determine the current usage of energy by the Mississippi State University, considering electricity and fuel separately. A variety of individual components likely to be employed in total energy systems are then considered in detail, including: solar assisted space heating system, space cooling system design, solar electric system, flat plate solar collector system, central solar receiver, and geothermal heat pump system. Also, algorithms have been developed for the approximate prediction of building heating and cooling loads based on gross parameters such as floor area, type of wall construction, etc. System considerations and evaluation are then presented. (LEW)

  6. Design of a bolometer for total-energy measurement of the linear coherent light source pulsed X-ray laser

    Energy Technology Data Exchange (ETDEWEB)

    Friedrich, S. [Lawrence Livermore National Laboratory, 7000 East Avenue, Livermore CA 94550 (United States)]. E-mail: Friedrich1@llnl.gov; Li, L. [Lawrence Livermore National Laboratory, 7000 East Avenue, Livermore CA 94550 (United States); Ott, L.L. [Lawrence Livermore National Laboratory, 7000 East Avenue, Livermore CA 94550 (United States); Kolgani, Rajeswari M. [Department of Physics, Geosciences and Astronomy, Towson University, 8000 York Avenue, Towson MD 21252 (United States); Yong, G.J. [Department of Physics, Geosciences and Astronomy, Towson University, 8000 York Avenue, Towson MD 21252 (United States); Ali, Z.A. [Lawrence Livermore National Laboratory, 7000 East Avenue, Livermore CA 94550 (United States); Drury, O.B. [Lawrence Livermore National Laboratory, 7000 East Avenue, Livermore CA 94550 (United States); Ables, E. [Lawrence Livermore National Laboratory, 7000 East Avenue, Livermore CA 94550 (United States); Bionta, R.M. [Lawrence Livermore National Laboratory, 7000 East Avenue, Livermore CA 94550 (United States)

    2006-04-15

    We are developing a cryogenic bolometer to measure the total energy of the linear coherent light source (LCLS) free electron X-ray laser to be built at the Stanford Linear Accelerator Center. The laser will produce ultrabright X-ray pulses in the energy range between 0.8 and 8 keV with {approx}10{sup 12} photons per {approx}200 fs pulse at a repeat interval of 8 ms, and will be accompanied by a halo of spontaneous undulator radiation. The bolometer is designed to determine the total energy of each laser pulse to within <0.1%, taking into account thermal and mechanical stress to prevent melting in the LCLS beam due to its high energy density. We propose to use a magnetoresistive Nd{sub (1-} {sub x} {sub )}Sr {sub x} MnO{sub 3} sensor array at the metal-insulator transition, where the composition x is adjusted to produce the desired transition temperature. We discuss design considerations and material choices, and present numerical simulations of the thermal response.

  7. Energy and exergy utilizations of the Chinese urban residential sector

    International Nuclear Information System (INIS)

    Liu, Yanfeng; Li, Yang; Wang, Dengjia; Liu, Jiaping

    2014-01-01

    Highlights: • The energy and exergy use in China’s urban residential sector between 2002 and 2011 are analyzed. • The primary locations and causes of energy and exergy losses in the CURS are identified. • The large gap between the energy and exergy efficiencies implies great potential for energy saving. • The exergy utilization can be improved by using appropriate technology, management and policy. - Abstract: In this paper, the energy and exergy utilizations in the Chinese urban residential sector (CURS) are analyzed by considering the energy and exergy flows for the years between 2002 and 2011. The energy and exergy efficiencies of this sector are calculated to examine the potential for advancing the ‘true’ energy efficiency and determine the real energy losses. The results demonstrate large differences between the overall energy efficiencies (62.8–70.2%) and the exergy efficiencies (11.0–12.2%) for the years analyzed. The sizable gap between the energy and exergy efficiencies implies a high potential for energy savings in the CURS. Future energy saving strategies should pay more attention to the improvement in exergy efficiencies. Moreover, it is found that direct fuel use constituted the primary exergy losses of the CURS; coal-fired boiler heating systems cause approximately 35% of the total exergy losses. Gas stoves, cogeneration systems, coal stoves and gas water heaters constitute 15.3%, 15%, 5.5% and 4.9% of the total exergy losses, respectively

  8. Brazilian Energy Balance 2016 - calendar year 2015

    International Nuclear Information System (INIS)

    2016-01-01

    The BEB is divided into eight chapters and ten annexes, whose contents are as follow. Chapter 1 - Energy Analysis and Aggregated Data - presents energy highlights per source in 2015 and analyses the evolution of the domestic energy supply and its relationship with economic growth. Chapter 2 - Energy Supply and Demand by Source - has the accountancy, per primary and secondary energy sources, of the production, import, export, variation of stocks, losses, adjustments and total consumption disaggregated per socioeconomic sector in the country. Chapter 3 - Energy Consumption by Sector - presents the final energy consumption classified by primary and secondary source for each sector of the economy. Chapter 4 - Energy Imports and Exports - presents the evolution of the data on the import and export of energy and the dependence on external energy. Chapter 5 - Balance of Transformation Centers - presents the energy balances for the energy transformation centers including their losses. Chapter 6 - Energy Resources and Reserves - has the basic concepts use in the survey of resources and reserves of primary energy sources. Chapter 7 - Energy and Socioeconomics - contains a comparison of energy, economic and population parameters, specific consumption, energy intensities, average prices and spending on petroleum imports. Chapter 8 - State Energy Data - presents energy data for the states by Federal Unit, main energy source production, energy installations, reserves and hydraulic potential. Relating to annexes the current structure is presented bellow: Annex I - Installed Capacity - shows the installed capacity of electricity generation, the installed capacity of Itaipu hydro plant and the installed capacity for oil refining. Annex II - Self-production of Electricity - presents disaggregated data of self-production, considering sources and sectors. Annex III - World Energy Data - presents the main indicators for the production, import, export and consumption per energy source

  9. High-Power-Density, High-Energy-Density Fluorinated Graphene for Primary Lithium Batteries

    Directory of Open Access Journals (Sweden)

    Guiming Zhong

    2018-03-01

    Full Text Available Li/CFx is one of the highest-energy-density primary batteries; however, poor rate capability hinders its practical applications in high-power devices. Here we report a preparation of fluorinated graphene (GFx with superior performance through a direct gas fluorination method. We find that the so-called “semi-ionic” C-F bond content in all C-F bonds presents a more critical impact on rate performance of the GFx in comparison with sp2 C content in the GFx, morphology, structure, and specific surface area of the materials. The rate capability remains excellent before the semi-ionic C-F bond proportion in the GFx decreases. Thus, by optimizing semi-ionic C-F content in our GFx, we obtain the optimal x of 0.8, with which the GF0.8 exhibits a very high energy density of 1,073 Wh kg−1 and an excellent power density of 21,460 W kg−1 at a high current density of 10 A g−1. More importantly, our approach opens a new avenue to obtain fluorinated carbon with high energy densities without compromising high power densities.

  10. Energy efficiency improvement and CO2 emission reduction opportunities in the cement industry in China

    International Nuclear Information System (INIS)

    Hasanbeigi, Ali; Morrow, William; Masanet, Eric; Sathaye, Jayant; Xu, Tengfang

    2013-01-01

    China's annual cement production (i.e., 1868 Mt) in 2010 accounted for nearly half of the world's annual cement production in the same year. We identified and analyzed 23 energy efficiency technologies and measures applicable to the processes in China's cement industry. The Conservation Supply Curve (CSC) used in this study is an analytical tool that captures both the engineering and the economic perspectives of energy conservation. Using bottom–up CSC models, the cumulative cost-effective and technical electricity and fuel savings, as well as the CO 2 emission reduction potentials for the Chinese cement industry for 2010–2030 are estimated. By comparison, the total final energy saving achieved by the implementation of these 23 efficiency measures in the Chinese cement industry over 20 years (2010–2030) is equal to 30% of the total primary energy supply of Latin America or Middle East or around 71% of primary energy supply of Brazil in 2007. In addition, a sensitivity analysis with respect to the discount rate is conducted to assess its effect on the results. The result of this study gives a comprehensive and easy to understand perspective to the Chinese cement industry and policy makers about the energy efficiency potential and its associated cost. - Highlights: ► Estimation of energy saving potential in the entire Chinese cement industry. ► Development of the bottom–up technology-rich Conservation Supply Curve models. ► Discussion of different approaches for developing conservation supply curves. ► Primary energy saving over 20 years equal to 33% of primary energy of Latin America

  11. Smart Energy Europe

    DEFF Research Database (Denmark)

    Connolly, D.; Lund, H.; Mathiesen, B. V.

    2016-01-01

    is presented in terms of energy (primary energy supply), environment (carbon dioxide emissions), and economy (total annual socio-economic cost). The steps are ordered in terms of their scientific and political certainty as follows: Decommissioning nuclear power, implementing a large amount of heat savings......This study presents one scenario for a 100% renewable energy system in Europe by the year 2050. The transition from a business-as-usual situation in 2050, to a 100% renewable energy Europe is analysed in a series of steps. Each step reflects one major technological change. For each step, the impact......, converting the private car fleet to electricity, providing heat in rural areas with heat pumps, providing heat in urban areas with district heating, converting fuel in heavy-duty vehicles to a renewable electrofuel, and replacing natural gas with methane. The results indicate that by using the Smart Energy...

  12. Cost and primary energy efficiency of small-scale district heating systems

    International Nuclear Information System (INIS)

    Truong, Nguyen Le; Gustavsson, Leif

    2014-01-01

    Highlights: • We analyzed minimum-cost options for small-scale DHSs under different contexts. • District heat production cost increases with reduced DHS scales. • Fewer technical options are suitable for small-scale DHSs. • Systems with combined technologies are less sensitive to changes in fuel prices. - Abstract: Efficient district heat production systems (DHSs) can contribute to achieving environmental targets and energy security for countries that have demands for space and water heating. The optimal options for a DHS vary with the environmental and social-political contexts and the scale of district heat production, which further depends on the size of the community served and the local climatic conditions. In this study, we design a small-scale, minimum-cost DHS that produces approximately 100 GWh heat per year and estimate the yearly production cost and primary energy use of this system. We consider conventional technologies, such as heat-only boilers, electric heat pumps and combined heat and power (CHP) units, as well as emerging technologies, such as biomass-based organic Rankine cycle (BORC) and solar water heating (SWH). We explore how different environmental and social-political situations influence the design of a minimum-cost DHS and consider both proven and potential technologies for small-scale applications. Our calculations are based on the real heat load duration curve for a town in southern Sweden. We find that the district heat production cost increases and that the potential for cogeneration decreases with smaller district heat production systems. Although the selection of technologies for a minimum-cost DHS depends on environmental and social-political contexts, fewer technical options are suitable for small-scale systems. Emerging technologies such as CHP-BORC and SWH improve the efficiency of primary energy use for heat production, but these technologies are more costly than conventional heat-only boilers. However, systems with

  13. Energy policy aspects

    International Nuclear Information System (INIS)

    Mattick, W.

    1980-01-01

    A general survey on the development of the total energy sector of the Federal Republic of Germany is given; the comparative presentations cover up to two decades. After some fundamental remarks on the development of the gross national product, primary energy and gross electricity consumption, as well as on the balance of performance and trade of the FRG with the OPEC countries the consumer behaviour is discussed in particular. This behaviour has scarcely changed between 1973 and 1979. The increasing demand and other omissions in the power plant construction resulting from various causes make stronger efforts in the construction of nuclear power plants necessary. (UA) [de

  14. Non-Renewable Energy and Macroeconomic Efficiency of Seven Major Oil Producing Economies in Africa

    Directory of Open Access Journals (Sweden)

    Awodumi Olabanji Benjamin

    2016-05-01

    Full Text Available This study adopted two-stage DEA to estimate the technical efficiency scores and assess the impact of the two most important components of fossil fuel associated with oil production on macroeconomic efficiency of Seven oil producing African countries during 2005-2012. Our results showed that increasing the consumption of natural gas would improve technical efficiency. Furthermore, increasing the share of fossil fuel in total energy consumption has negative effect on the efficiency of the economies of the top African oil producers. Also, we found that increasing the consumption of primary energy improves efficiency in these economies. We therefore, recommend that governments and other stakeholders in the energy industry should adopt inclusive strategies that will promote the use of natural gas in the short term. However, in the long-run, efforts should be geared towards increasing the use of primary energy, thereby reducing the percentage share of fossil fuel in total energy consumption.

  15. Modelling size-fractionated primary production in the Atlantic Ocean from remote sensing

    Science.gov (United States)

    Brewin, Robert J. W.; Tilstone, Gavin H.; Jackson, Thomas; Cain, Terry; Miller, Peter I.; Lange, Priscila K.; Misra, Ankita; Airs, Ruth L.

    2017-11-01

    Marine primary production influences the transfer of carbon dioxide between the ocean and atmosphere, and the availability of energy for the pelagic food web. Both the rate and the fate of organic carbon from primary production are dependent on phytoplankton size. A key aim of the Atlantic Meridional Transect (AMT) programme has been to quantify biological carbon cycling in the Atlantic Ocean and measurements of total primary production have been routinely made on AMT cruises, as well as additional measurements of size-fractionated primary production on some cruises. Measurements of total primary production collected on the AMT have been used to evaluate remote-sensing techniques capable of producing basin-scale estimates of primary production. Though models exist to estimate size-fractionated primary production from satellite data, these have not been well validated in the Atlantic Ocean, and have been parameterised using measurements of phytoplankton pigments rather than direct measurements of phytoplankton size structure. Here, we re-tune a remote-sensing primary production model to estimate production in three size fractions of phytoplankton (10 μm) in the Atlantic Ocean, using measurements of size-fractionated chlorophyll and size-fractionated photosynthesis-irradiance experiments conducted on AMT 22 and 23 using sequential filtration-based methods. The performance of the remote-sensing technique was evaluated using: (i) independent estimates of size-fractionated primary production collected on a number of AMT cruises using 14C on-deck incubation experiments and (ii) Monte Carlo simulations. Considering uncertainty in the satellite inputs and model parameters, we estimate an average model error of between 0.27 and 0.63 for log10-transformed size-fractionated production, with lower errors for the small size class (10 μm), and errors generally higher in oligotrophic waters. Application to satellite data in 2007 suggests the contribution of cells 2 μm to total

  16. GHG emissions from primary aluminum production in China: Regional disparity and policy implications

    International Nuclear Information System (INIS)

    Hao, Han; Geng, Yong; Hang, Wen

    2016-01-01

    Highlights: • GHG emissions from primary aluminum production in China were accounted. • The impact of regional disparity of power generation was considered for this study. • GHG emissions factor of China’s primary aluminum production was 16.5 t CO_2e/t Al ingot in 2013. • Total GHG emissions from China’s primary aluminum production were 421 mt CO_2e in 2013. - Abstract: China is the world-leading primary aluminum production country, which contributed to over half of global production in 2014. Primary aluminum production is power-intensive, for which power generation has substantial impact on overall Greenhouse Gas (GHG) emissions. In this study, we explore the impact of regional disparity of China’s power generation system on GHG emissions for the sector of primary aluminum production. Our analysis reveals that the national GHG emissions factor (GEF) of China’s primary aluminum production was 16.5 t CO_2e/t Al ingot in 2013, with province-level GEFs ranging from 8.2 to 21.7 t CO_2e/t Al ingot. There is a high coincidence of provinces with high aluminum productions and high GEFs. Total GHG emissions from China’s primary aluminum production were 421 mt CO_2e in 2013, approximately accounting for 4% of China’s total GHG emissions. Under the 2020 scenario, GEF shows a 13.2% reduction compared to the 2013 level, but total GHG emissions will increase to 551 mt CO_2e. Based on our analysis, we recommend that the government should further promote energy efficiency improvement, facilitate aluminum industry redistribution with low-carbon consideration, promote secondary aluminum production, and improve aluminum industry data reporting and disclosure.

  17. Mixing alcohol with energy drink (AMED) and total alcohol consumption : a systematic review and meta-analysis

    NARCIS (Netherlands)

    Verster, Joris C|info:eu-repo/dai/nl/241442702; Benson, Sarah; Johnson, Sean J; Scholey, Andrew; Alford, Chris

    It has been suggested that consuming alcohol mixed with energy drink (AMED) may increase total alcohol consumption. Aims of this systematic review and meta-analysis were (i) to compare alcohol consumption of AMED consumers with alcohol only (AO) consumers (between-group comparisons), and (ii) to

  18. Energy handbook - 2015 edition

    International Nuclear Information System (INIS)

    2015-01-01

    This memento about energy presents a series of tables with Key figures about energy in France and worldwide. All types of energy are discussed, with a specific focus on nuclear energy. Numerical data refer to energy resources and uses in France, in the European Union and in the rest of the world: Contents: 1 - Resources, consumption and production (Main energy units, Main power units, UK and metric units conversion, Common units for uranium, Conversion table for uranium compounds, Lower calorific value for coals, Basic data about hydrogen, France: primary energy accountancy, Energy equivalence for natural Uranium, Energy equivalence for fossil fuels); 2 - Resources (World: proved reserves of fossil fuels per geographical area at end 2014, most important uranium reserves, Renewable installed world capacity evolution; Europe: electricity production and installed capacity from wind and photovoltaic in the EU, installed capacity for offshore wind power in the EU countries); 3 - Consumption (Scenario of evolution of world population; World: general data for 2013, total primary energy supply, alternative scenario for primary energy supply, final consumption of energy for 2013, reference scenario for final consumption of energy; Europe: general data for 2013, biofuel consumption for transport in the European Union in 2014, Electricity consumption per head, Final energy consumption per GDP unit; France: primary energy consumption (corrected for climate) by energy, final energy consumption (corrected for climate) by energy, final energy consumption (corrected for climate) by sector, two retained scenarios in the DNTE context (National debate on energetic transition), electricity balances, energy balance for 2014); 4 - Production (World: 2012 electricity installed capacities, Electricity generation from nuclear power plants by country at the end of 2014, electricity generation by fuel for 2013, electricity generation, reference scenario for electricity generation; Europe

  19. Energy handbook - 2017 edition

    International Nuclear Information System (INIS)

    2017-01-01

    This memento about energy presents a series of tables with Key figures about energy in France and worldwide. All types of energy are discussed, with a specific focus on nuclear energy. Numerical data refer to energy resources and uses in France, in the European Union and in the rest of the world: Contents: 1 - resources, Consumption and Production - conversion tables: Main energy units, Main power units, Anglo-Saxon and metric units conversion, Common units for uranium, Conversion table for uranium compounds, Lower calorific value for coals, Basic data about hydrogen, France: primary energy accountancy, Energy equivalence for natural Uranium, Energy equivalence for fossil fuels; 2 - resources: World: proved reserves of fossil fuels per geographical area at end 2016, most important uranium reserves, Renewable installed world capacity evolution, Europe: electricity production and installed capacity from wind and photovoltaic in the EU, installed capacity for offshore wind power in the EU countries; 3 - Consumption: Scenario of evolution of world population, World: general data for 2015, total primary energy supply, reference scenario for primary energy supply, final consumption of energy for 2015, reference scenario for final consumption of energy, Europe: general data for 2015, bio-fuel consumption for transport in the European Union in 2016, Electricity consumption per head, Final energy consumption per GDP unit, France: primary energy consumption (corrected for climate) by energy, final energy consumption (corrected for climate) by energy, final energy consumption (corrected for climate) by sector, two retained scenarios in the DNTE context (National debate on energetic transition), electricity balances, energy balance for 2016; 4 - Production: World: 2014 electricity installed capacities, Electricity generation from nuclear power plants by country at the end of 2016, electricity generation by fuel for 2015, electricity generation, reference scenario for

  20. Energy handbook - 2016 edition

    International Nuclear Information System (INIS)

    2016-01-01

    This memento about energy presents a series of tables with Key figures about energy in France and worldwide. All types of energy are discussed, with a specific focus on nuclear energy. Numerical data refer to energy resources and uses in France, in the European Union and in the rest of the world: Contents: 1 - resources, Consumption and Production - conversion tables: Main energy units, Main power units, Anglo-Saxon and metric units conversion, Common units for uranium, Conversion table for uranium compounds, Lower calorific value for coals, Basic data about hydrogen, France: primary energy accountancy, Energy equivalence for natural Uranium, Energy equivalence for fossil fuels; 2 - resources: World: proved reserves of fossil fuels per geographical area at end 2015, most important uranium reserves, Renewable installed world capacity evolution, Europe: electricity production and installed capacity from wind and photovoltaic in the EU, installed capacity for offshore wind power in the EU countries; 3 - Consumption: Scenario of evolution of world population, World: general data for 2014, total primary energy supply, reference scenario for primary energy supply, final consumption of energy for 2014, reference scenario for final consumption of energy, Europe: general data for 2014, bio-fuel consumption for transport in the European Union in 2015, Electricity consumption per head, Final energy consumption per GDP unit, France: primary energy consumption (corrected for climate) by energy, final energy consumption (corrected for climate) by energy, final energy consumption (corrected for climate) by sector, two retained scenarios in the DNTE context (National debate on energetic transition), electricity balances, energy balance for 2015; 4 - Production: World: 2013 electricity installed capacities, Electricity generation from nuclear power plants by country at the end of 2015, electricity generation by fuel for 2014, electricity generation, reference scenario for

  1. Original Article Blood Loss and Influencing Factors in Primary Total ...

    African Journals Online (AJOL)

    KIGZ

    aid the surgeon in the African region estimate the expected blood loss after total hip replacement. We conducted a study to quantify the blood loss following total hip arthroplasty and to determine the factors .... Hemoglobin European Overview (OSTHEO) study: blood management in elective knee and hip arthroplasty in ...

  2. Consumption and correlates of sweet foods, carbonated beverages, and energy drinks among primary school children in Saudi Arabia.

    Science.gov (United States)

    Alsubaie, Ali Saad R

    2017-10-01

    To assess the consumption of sweets, carbonated beverages, and energy drinks along with their correlates among primary school children.  Methods: A total of 725 children (7-12 years old) were randomly recruited from 10 elementary schools from Al-Baha city, Saudi Arabia in 2013, using a multi-stage stratified sampling technique and pre-tested validated questionnaire.  Results: Approximately 26.1% of children reported consuming sweets on daily basis, and 63.4% consumed sweets occasionally during the week. Approximately 56.3%children were reportedly drinking carbonated beverages weekly and 17.1% in daily basis. Weekly consumption of energy drinks was reported in 21.9% and daily consumption in 4.3% of the children. Daily sweets consumption was positively associated with children age (odds ratio [OR]=1.5, 95% confidence interval [CI]: 4.5-9.5, p=0.035), consuming carbonated beverages (OR=3.4, 95% CI: 2.2-5.2, p less than 0.001), energy drinks (OR=2.5, 95% CI: 1.1-5.4, p=0.029), eating high fat food (OR= 1.6, 95% CI: 1.1 - 2.4, p=0.023), and inversely with children body mass index (BMI) (OR=0.9, 95% CI: 0.8-0.9, p less than 0.001). Consuming carbonated beverages on regular basis was positively associated with consuming energy drinks (OR=9.0, 95% CI: 4.0-21.0, p less than 0.001).  Conclusion: Unhealthy dietary choices were found to be prevalent at early age. Comprehensive intervention programs should be established to prevent unhealthy dietary choices and promote healthier dietary behaviors. Qualitative studies are needed for better understanding of children's dietary behaviors.

  3. France energy assessment for 2009

    International Nuclear Information System (INIS)

    2010-01-01

    Illustrated by graphs and data tables, this report first describes the economic and energy context (world recession, French macro-economic context, climate data, energy costs), analyses the present evolution of the primary energy total demand (it decreased by 5 per cent). It analyses the energy supply for coal, oil, natural gas, electricity, renewable energies and wastes. It discusses the issue of energy transformation and transportation. It analyses the decrease of energy consumption for all non renewable energies (coal, oil, natural gas, electricity) and the significant increase of renewable energy consumption. It comments the decrease of final energy consumption in all economic sectors (industry, housing and office building, agriculture and fishery, transports). It outlines that advances in final energy economy have been hampered by the economic crisis. It comments the rather decrease of CO 2 emissions related to energy consumption. Within this context, the energy bill presented a 33 per cent decrease, but remains quite heavy for the French economy

  4. Absence of a Scott correction for the total binding energy of noninteracting fermions in a smooth potential well

    International Nuclear Information System (INIS)

    Huxtable, B.D.

    1988-01-01

    It is shown, for V in a particular class of smooth functions, that the total binding energy, E(Z), of Z noninteracting Fermions in the potential well Z 4/3 V(Z 1/3 X) obeys E(Z) = c TF (V)Z 7/3 + O(Z 5/3 ) as Z → ∞. Here c TF (V) is the coefficient predicted by Thomas-Fermi theory. This result is consistent with the conjectured Scott correction, which occurs at order Z 2 , to the total binding energy of an atomic number Z. This correction is thought to arise only because V(x)∼ - |x| -1 near x = 0 in the atomic problem, and so V is not a smooth function

  5. Embedded piezoelectrics for sensing and energy harvesting in total knee replacement units

    Science.gov (United States)

    Wilson, Brooke E.; Meneghini, Michael; Anton, Steven R.

    2015-04-01

    The knee replacement is the second most common orthopedic surgical intervention in the United States, but currently only 1 in 5 knee replacement patients are satisfied with their level of pain reduction one year after surgery. It is imperative to make the process of knee replacement surgery more objective by developing a data driven approach to ligamentous balance, which increases implant life. In this work, piezoelectric materials are considered for both sensing and energy harvesting applications in total knee replacement implants. This work aims to embed piezoelectric material in the polyethylene bearing of a knee replacement unit to act as self-powered sensors that will aid in the alignment and balance of the knee replacement by providing intraoperative feedback to the surgeon. Postoperatively, the piezoelectric sensors can monitor the structural health of the implant in order to perceive potential problems before they become bothersome to the patient. Specifically, this work will present on the use of finite element modeling coupled with uniaxial compression testing to prove that piezoelectric stacks can be utilized to harvest sufficient energy to power sensors needed for this application.

  6. Energy and IAQ Implications of Alternative Minimum Ventilation Rates in California Retail and School Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Dutton, Spencer M. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Fisk, William J. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2015-01-01

    For a stand-alone retail building, a primary school, and a secondary school in each of the 16 California climate zones, the EnergyPlus building energy simulation model was used to estimate how minimum mechanical ventilation rates (VRs) affect energy use and indoor air concentrations of an indoor-generated contaminant. The modeling indicates large changes in heating energy use, but only moderate changes in total building energy use, as minimum VRs in the retail building are changed. For example, predicted state-wide heating energy consumption in the retail building decreases by more than 50% and total building energy consumption decreases by approximately 10% as the minimum VR decreases from the Title 24 requirement to no mechanical ventilation. The primary and secondary schools have notably higher internal heat gains than in the retail building models, resulting in significantly reduced demand for heating. The school heating energy use was correspondingly less sensitive to changes in the minimum VR. The modeling indicates that minimum VRs influence HVAC energy and total energy use in schools by only a few percent. For both the retail building and the school buildings, minimum VRs substantially affected the predicted annual-average indoor concentrations of an indoor generated contaminant, with larger effects in schools. The shape of the curves relating contaminant concentrations with VRs illustrate the importance of avoiding particularly low VRs.

  7. The GDP-Energy Link

    International Nuclear Information System (INIS)

    Bourdaire, J.M.

    2000-01-01

    The analysis of primary or final energy consumptions as a function of total regional GDP, aggregated on the basis of purchasing power parities, does not bring significant results for the transition economies because of the poor quality of their data. Conversely, for the market economies, such an analysis highlights the regularity of the trends as long as final prices remain unchanged, the nature of energy shock impacts and the close relationship between the energy intensity and the level of final prices. French energy evolutions are similar and lead to question what the benefits brought by energy efficiency policies are. These benefits seem to be qualitative only, i.e. more comfort and well-being, with no indication of lesser energy consumption as long as the final prices remain unchanged. The conclusion is three-fold: importance of prices reflecting all costs, choice of supply policies which can shoulder energy shocks, and need to continue and deepen the energy debate. (authors)

  8. Energy saving opportunity with variable speed drive in primary air-handling unit

    International Nuclear Information System (INIS)

    Li, J.S.M.

    2007-01-01

    Air conditioners used in the court buildings in Kowloon City, Hong Kong were retrofitted with variable speed drives in the primary air handling unit (PAU) in an effort to reduce energy consumption. The initial effect of this retrofit was investigated along with the feasibility of using a carbon dioxide (CO 2 ) based demand control ventilation to reduce energy consumption while optimizing indoor air quality. The air flow in most air conditioning fans is either constant or controlled by motorized inlet guide vanes. Although this controls the flow and may reduce the load on the fan, this constriction adds an energy loss, resulting in inefficient operation. Variable speed drives should be used on the PAU in order to maintain system efficiency. As the speed of the fans are reduced, the flow will decrease proportionally, while the power required by the fan will reduce the cube of the speed. Therefore, if the fresh air supply can be controlled by reducing the speed of the fan motor, then flow control would be more efficient. The energy saving associated with variable fresh air supply flow rate was evaluated along with the cost to building owners. This paper presented the results of the potential energy and cost savings associated with this retrofit, and included implementation cost and pay back period. It was estimated that about 20 per cent of power consumption and electricity costs can be saved per year, with a simple payback period of 2 years. 7 refs., 3 tabs., 3 figs

  9. On the dependance of the ''normalized multiplicity'' of particles produced in proton-nucleus interactions on the primary energy

    International Nuclear Information System (INIS)

    Babecki, J.

    1975-01-01

    The mean ''normalized multiplicities'' of particles produced in p-nucleus interactions: with the leading particles (R 1 ) and without them (R 2 ) were calculated from the emulsion data. The independence of R 2 of the primary energy E 0 were stated in very wide interval of E 0 from 6.2 to thousands of GeV. R 2 is approximately equal to the mean number of collisions of the primary particle in the nucleus. (author)

  10. The Study of Prompt and Delayed Muon Induced Fission. I.Total kinetic energies and mass distributions

    NARCIS (Netherlands)

    David, P; Hartfiel, J.; Janszen, H.; Petitjean, C.; Reist, H.W.; Polikanov, S.M.; Konijn, J.; Laat, de C.T.A.M.; Taal, A.; Krogulski, T.; Johansson, T.; Tibell, G.; Achard van Enschut, d' J.F.M.

    1987-01-01

    Mass yield and total kinetic energy release (TKE) distributions of fragments from prompt and delayed muon induced fission, separately, have been measured for the isotopes235U,238U,237Np and242Pu. The distributions from prompt muon induced fission are compared with the corresponding distributions

  11. Total energy calculations for structural phase transformations

    International Nuclear Information System (INIS)

    Ye, Y.Y.; Chan, C.T.; Ho, K.M.; Harmon, B.N.

    1990-01-01

    The structural integrity and physical properties of crystalline solids are frequently limited or enhanced by the occurrence of phase transformations. Martensitic transformations involve the collective displacement of atoms from one ordered state to another. Modern methods to determine the microscopic electronic changes as the atoms move are now accurate enough to evaluate the very small energy differences involved. Extensive first principles calculations for the prototypical martensitic transformation from body-centered cubic (bcc) to closepacked 9R structure in sodium metal are described. The minimum energy coordinate or configuration path between the bcc and 9R structures is determined as well as paths to other competing close-packed structures. The energy barriers and important anharmonic interactions are identified and general conclusions drawn. The calculational methods used to solve the Schrodinger equation include pseudopotentials, fast Fourier transforms, efficient matrix diagnonalization, and supercells with many atoms

  12. Classical calculation of the total ionization energy of helium-like atoms

    International Nuclear Information System (INIS)

    Karastoyanov, A.

    1990-01-01

    Quantum mechanics rejects the classical modelling of microworld. One of the reasons is that the Bohr's rules can not be applied for many-electron atoms and molecules. But the many-body problem in classical mechanics has no analytical solution even for 3 particles. Numerical solutions should be used. The quantum Bohr's rule expressing the moment of momentum conservation for two particles is invalid in more complicated cases. Yet Bohr reached some success for helium-like atoms. The Bohr's formula concerning helim-like atoms is deduced again in this paper and its practical reliability is analyzed with contemporary data. The binding energy of the system is obtained in the simple form E=(Z-1/4) 2 α 2 mc 2 , where Z is the atomic number, α - the fine structure constant, M - the electron mass and c - the light speed in vacuum. The calculated values are compared with experimental data on the total ionization energy of the helium-like atoms from 2 He 4 to 29 Cu 64 . The error decreases quickly with the increasing of atomic mass, reaching zero for Cu. This indicated that the main source of error is the nucleus motion. The role of other possible causes is analyzed and proves negligible. (author). 1 tab, 4 refs

  13. Total Energy Recovery System for Agribusiness: Lake County study. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Fogleman, S.F.; Fisher, L.A.; Black, A.R.

    1978-04-01

    A brief summary is given of the results of a previously reported study designed to evaluate the costs and viability of combined thermodynamic and biologic cycles in a system known as the Total Energy Recovery System for Agribusiness (TERSA). This conceptual system involved the combined geothermally assisted activities of greenhouse crop and mushroom growing, fish farming, and biogas generation in an integrated biologic system such that the waste or by-products of each subsystem cycle were recovered to service input needs of companion cycles. An updated direct use geothermal system based on TERSA that is viable for implementation in Lake County is presented. Particular consideration is given to: location of geothermal resources, availability of land and irrigation quality water, compatibility of the specific direct use geothermal activities with adjacent and local uses. Private interest and opposition, and institutional factors as identified. Factors relevant to local TERSA implementation are discussed, followed by sites considered, selection criteria, site slection, and the modified system resulting. Particular attention is paid to attempt to make clear the process followed in applying this conceptual design to the specific task of realistic local implementation. Previous publications on geothermal energy and Lake County are referenced where specific details outside the scope of this study may be found. (JGB)

  14. The role of eating frequency on total energy intake and diet quality in a low-income, racially diverse sample of schoolchildren.

    Science.gov (United States)

    Evans, E Whitney; Jacques, Paul F; Dallal, Gerard E; Sacheck, Jennifer; Must, Aviva

    2015-02-01

    The relationship of meal and snacking patterns with overall dietary intake and relative weight in children is unclear. The current study was done to examine how eating, snack and meal frequencies relate to total energy intake and diet quality. The cross-sectional associations of eating, meal and snack frequencies with total energy intake and diet quality, measured by the Healthy Eating Index 2005 (HEI-2005), were examined in separate multivariable mixed models. Differences were examined between elementary school-age participants (9-11 years) and adolescents (12-15 years). Two non-consecutive 24 h diet recalls were collected from children attending four schools in the greater Boston area, MA, USA. One hundred and seventy-six schoolchildren, aged 9-15 years. Overall, 82% of participants consumed three daily meals. Eating, meal and snack frequencies were statistically significantly and positively associated with total energy intake. Each additional reported meal and snack was associated with an 18·5% and a 9·4% increase in total energy intake, respectively (Pquality differed by age category. In elementary school-age participants, total eating occasions and snacks increased HEI-2005 score. In adolescents, each additional meal increased HEI-2005 score by 5·40 points (P=0·01), whereas each additional snack decreased HEI-2005 score by 2·73 points (P=0·006). Findings suggest that snacking increases energy intake in schoolchildren. Snacking is associated with better diet quality in elementary school-age children and lower diet quality in adolescents. Further research is needed to elucidate the role of snacking in excess weight gain in children and adolescents.

  15. A Comprehensive Energy Analysis and Related Carbon Footprint of Dairy Farms, Part 1: Direct Energy Requirements

    Directory of Open Access Journals (Sweden)

    Giuseppe Todde

    2018-02-01

    Full Text Available Dairy cattle farms are continuously developing more intensive systems of management which require higher utilization of durable and not-durable inputs. These inputs are responsible of significant direct and indirect fossil energy requirements which are related to remarkable emissions of CO2. This study aims to analyze direct energy requirements and the related carbon footprint of a large population of conventional dairy farms located in the south of Italy. A detailed survey of electricity, diesel and Liquefied Petroleum Gas (LPG consumptions has been carried out among on-farm activities. The results of the analyses showed an annual average fuel consumption of 40 kg per tonne of milk, while electricity accounted for 73 kWh per tonne of milk produced. Expressing the direct energy inputs as primary energy, diesel fuel results the main resource used in on-farm activities, accounting for 72% of the total fossil primary energy requirement, while electricity represents only 27%. Moreover, larger farms were able to use more efficiently the direct energy inputs and reduce the related emissions of carbon dioxide per unit of milk produced, since the milk yield increases with the herd size. The global average farm emissions of carbon dioxide equivalent, due to all direct energy usages, accounted for 156 kg CO2-eq per tonne of Fat and Protein Corrected Milk (FPCM, while farms that raise more than 200 heads emitted 36% less than the average value. In this two-part series, the total energy demand (Part 1 + Part 2 per farm is mainly due to agricultural inputs and fuel consumption, which have the largest quota of the annual requirements for each milk yield class. These results also showed that large size farms held lower CO2-eq emissions when referred to the mass of milk produced.

  16. Effects of primary recoil (PKA) energy spectrum on radiation damage in fcc metals

    International Nuclear Information System (INIS)

    Iwata, Tadao; Iwase, Akihiro

    1997-10-01

    Irradiation effects by different energetic particles such as electrons, various ions and neutrons are compared in fcc metals, particularly in Cu and Ni. It is discussed on the statistical consideration that the logarithm of the so-called PKA median energy, log T 1/2 , is a good representative to characterize the primary recoil (i.e. PKA) energy spectrum with the resultant defect production. For the irradiations of electrons, various ions and neutrons to Cu and Ni, fundamental physical quantities such as the fraction of stage I recovery, the defect production cross sections and the radiation annealing cross sections can be well scaled as a function of log T 1/2 , if the effects of the electron excitation caused by irradiating ions are excluded. Namely, all data of the respective physical quantity lie on a single continuous curve as a function of log T 1/2 . This characteristic curve is utilized to predict the damage accumulation (i.e. defect concentration) as a function of dpa in Cu and Ni with the PKA median energy as a parameter. (author)

  17. Effects of primary recoil (PKA) energy spectrum on radiation damage in fcc metals

    Energy Technology Data Exchange (ETDEWEB)

    Iwata, Tadao; Iwase, Akihiro [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    1997-10-01

    Irradiation effects by different energetic particles such as electrons, various ions and neutrons are compared in fcc metals, particularly in Cu and Ni. It is discussed on the statistical consideration that the logarithm of the so-called PKA median energy, log T{sub 1/2}, is a good representative to characterize the primary recoil (i.e. PKA) energy spectrum with the resultant defect production. For the irradiations of electrons, various ions and neutrons to Cu and Ni, fundamental physical quantities such as the fraction of stage I recovery, the defect production cross sections and the radiation annealing cross sections can be well scaled as a function of log T{sub 1/2}, if the effects of the electron excitation caused by irradiating ions are excluded. Namely, all data of the respective physical quantity lie on a single continuous curve as a function of log T{sub 1/2}. This characteristic curve is utilized to predict the damage accumulation (i.e. defect concentration) as a function of dpa in Cu and Ni with the PKA median energy as a parameter. (author)

  18. Real-space formulation of the electrostatic potential and total energy of solids

    International Nuclear Information System (INIS)

    Pask, J E; Sterne, P A

    2004-01-01

    We develop expressions for the electrostatic potential and total energy of crystalline solids which are amenable to direct evaluation in real space. Unlike conventional reciprocal space formulations, no Fourier transforms or reciprocal lattice summations are required, and the formulation is well suited for large-scale, parallel computations. The need for reciprocal space expressions is eliminated by replacing long-range potentials by equivalent localized charge distributions and incorporating long-range interactions into boundary conditions on the unit cell. In so doing, a simplification of the conventional reciprocal space formalism is obtained. The equivalence of the real- and reciprocal space formalisms is demonstrated by direct comparison in self-consistent density-functional calculations

  19. The level of energy sufficiency - why all the controversy?

    International Nuclear Information System (INIS)

    Maillard, D.

    2000-01-01

    It as become fashionable in certain circles to attempt to demolish the notion of energy sufficiency, a concept which is now seen as being archaic and unsuitable. To back up their claims, proponents of this standpoint take great pleasure in attacking the corresponding indicator - the rate of energy sufficiency calculated as a ratio of national primary energy production and the total consumption of primary energy (in the same unit and without climatic corrections). Confirming its precarious, conventional and debatable nature seems in their eyes to be the best means of ensuring that both the word, the concept and the measuring method of energy sufficiency are consigned to the dustbin of economic history. After having examined with perhaps a certain irony some of the usual criticisms, I intend to proceed with a re-examination of questions which in my eyes appear to be essential. (author)

  20. The Total Energy Efficiency Index for machine tools

    International Nuclear Information System (INIS)

    Schudeleit, Timo; Züst, Simon; Weiss, Lukas; Wegener, Konrad

    2016-01-01

    Energy efficiency in industries is one of the dominating challenges of the 21st century. Since the release of the eco-design directive 2005/32/EC in 2005, great research effort has been spent on the energy efficiency assessment for energy using products. The ISO (International Organization for Standardization) standardization body (ISO/TC 39 WG 12) currently works on the ISO 14955 series in order to enable the assessment of energy efficient design of machine tools. A missing piece for completion of the ISO 14955 series is a metric to quantify the design of machine tools regarding energy efficiency based on the respective assembly of components. The metric needs to take into account each machine tool components' efficiency and the need-oriented utilization in combination with the other components while referring to efficiency limits. However, a state of the art review reveals that none of the existing metrics is feasible to adequately match this goal. This paper presents a metric that matches all these criteria to promote the development of the ISO 14955 series. The applicability of the metric is proven in a practical case study on a turning machine. - Highlights: • Study for pushing forward the standardization work on the ISO 14955 series. • Review of existing energy efficiency indicators regarding three basic strategies to foster sustainability. • Development of a metric comprising the three basic strategies to foster sustainability. • Metric application for quantifying the energy efficiency of a turning machine.