WorldWideScience

Sample records for total pressure difference

  1. Total Site Heat Integration Considering Pressure Drops

    Directory of Open Access Journals (Sweden)

    Kew Hong Chew

    2015-02-01

    Full Text Available Pressure drop is an important consideration in Total Site Heat Integration (TSHI. This is due to the typically large distances between the different plants and the flow across plant elevations and equipment, including heat exchangers. Failure to consider pressure drop during utility targeting and heat exchanger network (HEN synthesis may, at best, lead to optimistic energy targets, and at worst, an inoperable system if the pumps or compressors cannot overcome the actual pressure drop. Most studies have addressed the pressure drop factor in terms of pumping cost, forbidden matches or allowable pressure drop constraints in the optimisation of HEN. This study looks at the implication of pressure drop in the context of a Total Site. The graphical Pinch-based TSHI methodology is extended to consider the pressure drop factor during the minimum energy requirement (MER targeting stage. The improved methodology provides a more realistic estimation of the MER targets and valuable insights for the implementation of the TSHI design. In the case study, when pressure drop in the steam distribution networks is considered, the heating and cooling duties increase by 14.5% and 4.5%.

  2. Effect of total pressure on graphite oxidation

    International Nuclear Information System (INIS)

    Burnette, R.D.; Hoot, C.G.

    1983-04-01

    Graphite corrosion in the high-temperature gas-cooled reactor (HTGR) is calculated using two key assumptions: (1) the kinetic, catalysis, and transport characteristics of graphite determined by bench-scale tests apply to large components at reactor conditions and (2) the effects of high pressure and turbulent flow are predictable. To better understand the differences between laboratory tests and reactor conditions, a high-pressure test loop (HPTL) has been constructed and used to perform tests at reactor temperature, pressure, and flow conditions. The HPTL is intended to determine the functional dependence of oxidation rate and characteristics on total pressure and gas velocity and to compare the oxidation results with calculations using models and codes developed for the reactor

  3. Influence of Different Patellofemoral Design Variations Based on Genesis II Total Knee Endoprosthesis on Patellofemoral Pressure and Kinematics.

    Science.gov (United States)

    Leichtle, Ulf G; Lange, Barbara; Herzog, Yvonne; Schnauffer, Peter; Leichtle, Carmen I; Wülker, Nikolaus; Lorenz, Andrea

    2017-01-01

    In total knee arthroplasty (TKA), patellofemoral groove design varies greatly and likely has a distinct influence on patellofemoral biomechanics. To analyse the selective influence, five patellofemoral design variations were developed based on Genesis II total knee endoprosthesis (original design, being completely flat, being laterally elevated, being medially elevated, and both sides elevated) and made from polyamide using rapid prototyping. Muscle-loaded knee flexion was simulated on 10 human knee specimens using a custom-made knee simulator, measuring the patellofemoral pressure distribution and tibiofemoral and patellofemoral kinematics. The measurements were carried out in the native knee as well as after TKA with the 5 design prototypes. The overall influence of the different designs on the patellofemoral kinematics was small, but we found detectable effects for mediolateral tilt ( p patellofemoral pressures, major interindividual differences were seen between the designs, which, on average, largely cancelled each other out. These results suggest that the elevation of the lateral margin of the patellofemoral groove is essential for providing mediolateral guidance, but smooth contouring as with original Genesis II design seems to be sufficient. The pronounced interindividual differences identify a need for more patellofemoral design options in TKA.

  4. Segmental blood pressure after total hip replacement

    DEFF Research Database (Denmark)

    Gebuhr, Peter Henrik; Soelberg, M; Henriksen, Jens Henrik Sahl

    1992-01-01

    Twenty-nine patients due to have a total hip replacement had their systemic systolic and segmental blood pressures measured prior to operation and 1 and 6 weeks postoperatively. No patients had signs of ischemia. The segmental blood pressure was measured at the ankle and at the toes. A significant...... drop was found in all pressures 1 week postoperatively. The decrease followed the systemic pressure and was restored to normal after 6 weeks. In a group of six patients with preoperatively decreased ankle pressure, a significant transient further decrease in the ankle-toe gradient pressure was found...... on the operated side. None of the patients had symptoms from the lowered pressure. We conclude that in patients without signs of ischemia, the postoperative segmental pressure decrease is reversible and therefore not dangerous....

  5. Compressor Research Facility F100 High Pressure Compressor Inlet Total Pressure and Swirl Profile Simulation.

    Science.gov (United States)

    1984-10-01

    1627 VANE ANGLE- U SCREE 4 S,,, L53 S 6 4 NSW, 153 Figure 139. Total Pressure Profile Figure 140. Total Pressure Profile (Phase III), PSV = 250 (Phase...STATION 2.5 , PT. 1-1574- 1585 VANE ANGLE- 15 PT. 0-IMB 8- 150 VANE ANGLE= 21SCREENS- 4 I 54 SDIENS-4 X L53 Figure 137. Total Pressure Profile Figure 138...A 53: if 1-4;2.A 54: for L-10 to 16;wrt 709,"ASVN5SOIVFIVSIVT3VS"for J-l to 5 *55: r!-’ 709,E[A,L,J);nex~t ,I-r~eXt f! *56: if 1-1;wrt 709," TD )"red

  6. Research on axial total pressure distributions of sonic steam jet in subcooled water

    International Nuclear Information System (INIS)

    Wu Xinzhuang; Li Wenjun; Yan Junjie

    2012-01-01

    The axial total pressure distributions of sonic steam jet in subcooled water were experimentally investigated for three different nozzle diameters (6.0 mm, 8.0 mm and 10.0 mm). The inlet steam pressure, and pool subcooling subcooled water temperature were in the range of 0.2-0.6 MPa and 420-860 ℃, respectively. The effect of steam pressure, subcooling water temperature and nozzle size on the axial pressure distributions were obtained, and also the characteristics of the maximum pressure and its position were studied. The results indicated that the characteristics of the maximum pressure were influenced by the nozzle size for low steam pressure, but the influence could be ignored for high steam pressure. Moreover, a correlation was given to correlate the position of the maximum pressure based on steam pressure and subcooling water temperature, and the discrepancies of predictions and experiments are within ±15%. (authors)

  7. Inter-arm blood pressure differences in pregnant women.

    Science.gov (United States)

    Poon, L C Y; Kametas, N; Strobl, I; Pachoumi, C; Nicolaides, K H

    2008-08-01

    To determine the prevalence of blood pressure inter-arm difference (IAD) in early pregnancy and to investigate its possible association with maternal characteristics. A cross-sectional observational study. Routine antenatal visit in a university hospital. A total of 5435 pregnant women at 11-14 weeks of gestation. Blood pressure was taken from both arms simultaneously with a validated automated device. The presence of inter-arm blood pressure difference of 10 mmHg or more. The IAD in systolic and diastolic blood pressure was 10 mmHg or more in 8.3 and 2.3% of the women, respectively. Systolic IAD was found to be significantly related to systolic blood pressure and pulse pressure, and diastolic IAD was found to be significantly related to maternal age, diastolic blood pressure and pulse pressure. The systolic and diastolic IAD were higher in the hypertensive group compared with the normotensive group and absolute IAD increased with increasing blood pressure. About 31.0 and 23.9% of cases of hypertension would have been underreported if the left arm and the right arm were used, respectively, in measuring the blood pressure. There is a blood pressure IAD in a significant proportion of the pregnant population, and its prevalence increases with increasing blood pressure. By measuring blood pressure only on one arm, there is a one in three chance of underreporting hypertension. Therefore, it would be prudent that during the booking visit blood pressure should be taken in both arms and thus provide guidance for subsequent blood pressure measurements during the course of pregnancy.

  8. Hydro-isomerization of n-hexane on bi-functional catalyst: Effect of total and hydrogen partial pressures

    Science.gov (United States)

    Thoa, Dao Thi Kim; Loc, Luu Cam

    2017-09-01

    The effect of both total pressure and hydrogen partial pressure during n-hexane hydro-isomerization over platinum impregnated on HZSM-5 was studied. n-Hexane hydro-isomerization was conducted at atmospheric pressure and 0.7 MPa to observe the influence of total pressure. In order to see the effect of hydrogen partial pressure, the reaction was taken place at different partial pressure of hydrogen varied from 307 hPa to 718 hPa by dilution with nitrogen to keep the total pressure at 0.1 MPa. Physico-chemical characteristics of catalyst were determined by the methods of nitrogen physi-sorption BET, SEM, XRD, TEM, NH3-TPD, TPR, and Hydrogen Pulse Chemi-sorption. Activity of catalyst in the hydro-isomerization of n-hexane was studied in a micro-flow reactor in the temperature range of 225-325 °C; the molar ratio H2/ hydrocarbon: 5.92, concentration of n-hexane: 9.2 mol.%, GHSV 2698 h-1. The obtained catalyst expressed high acid density, good reducing property, high metal dispersion, and good balance between metallic and acidic sites. It is excellent contact for n-hexane hydro-isomerization. At 250 °C, n-hexane conversion and selectivity were as high as 59-76 % and 85-99 %, respectively. It was found that catalytic activity was promoted either by total pressure or hydrogen partial pressure. At total pressure of 0.7 MPa while hydrogen partial pressure of 718 hPa, catalyst produced 63 RON liquid product containing friendly environmental iso-paraffins which is superior blending stock for green gasoline. Hydrogen did not only preserve catalyst actives by depressing hydrocracking and removing coke precursors but also facilitated hydride transfer step in the bi-functional bi-molecular mechanism.

  9. Differences Between Right and Left Arm Blood Pressures in the Elderly

    OpenAIRE

    Hashimoto, Fred; Hunt, William C.; Hardy, Linda

    1984-01-01

    Recommendations vary on whether blood pressures should be measured in the right or in the left arm because no frequency distributions for a pressure difference between the arms exist. We took a total of 12 blood pressure determinations in both arms of 174 elderly persons and analyzed the data by a least-squares components of variance method. The mean difference between the arms (right minus left) was 0.93 mm of mercury for systole and 0.70 mm of mercury for diastole. For systole the proportio...

  10. The influence of different auto-ignition modes on the behavior of pressure waves

    International Nuclear Information System (INIS)

    Xu, Han; Yao, Anren; Yao, Chunde

    2015-01-01

    Highlights: • Modes of pressure oscillations in knocking, HCCI and super knock are recognized. • Three representative auto-ignition modes in engines are proposed. • A new method of “Energy Injected” is brought into understanding pressure wave. • Simulation results revealed the decisive factors for these three auto-ignition modes. • Different modes lead to different pressure wave behaviors damaging engines. - Abstract: For internal combustion engines, the knock of Homogeneous Charge Compression Ignition engines, the conventional knock of gasoline engines and the super knock are all caused by the auto-ignition of unburned mixture which leads to the oscillation burning, but their Maximal Pressure Oscillation Amplitude (MPOA) and Maximum Pressure Rising Rate (MPRR) are totally different. In order to explore the reason, we propose three typical auto-ignition modes and then bring up the method of “Energy Injected” (EI) which is based on the experiment measured heat release rate. Through changing the heat source term in the energy equation for different auto-ignition modes, we conducted a series of numerical simulations for these three modes. After that, the following pressure oscillations can be compared and analyzed. The numerical simulation results show that different combustion pressure waves with different oscillation characteristics come from different auto-ignition modes, thus the macroscopic MPRR and MPOA are totally different. Furthermore, the method of “EI” based on the experiment measured heat release rate can accurately and rapidly help to research the formation and propagation of pressure waves in the engine combustion chamber.

  11. Hydrogen production by the iodine-sulphur thermochemical cycle. Total and partial pressure measurements

    International Nuclear Information System (INIS)

    D Doizi; V Dauvois; J L Roujou; V Delanne; P Fauvet; B Larousse; O Hercher; P Carles; C Moulin

    2006-01-01

    The iodine sulphur thermochemical cycle appears to be one of the most promising candidate for the massive production of hydrogen using nuclear energy. The key step in this cycle is the HI distillation section which must be optimized to get a good efficiency of the overall cycle. The concept of reactive versus extractive distillation of HI has been proposed because of its potentiality. The design and the optimization of the reactive distillation column requires the knowledge of the liquid vapour equilibrium over the ternary HI-I 2 -H 2 O mixtures up to 300 C and 100 bars. A general methodology based on three experimental devices imposed by the very corrosive and concentrated media will be described: 1) I1 for the total pressure measurement versus different ternary compositions. 2) I2 for the partial and total pressure measurements around 130 C and 2 bars to validate the choice of the analytical optical 'online' techniques we have proposed. 3) I3 for the partial and total pressures measurements in the process domain. The results obtained on pure samples, binary mixtures HI-H 2 O and ternary mixtures using an experimental design analysis in the experimental device I2 will be discussed. (authors)

  12. Determination of total carbonates in soil archaeometry using a new pressure method with temperature compensation

    Science.gov (United States)

    Barouchas, Pantelis; Koulos, Vasilios; Melfos, Vasilios

    2017-04-01

    For the determination of total carbonates in soil archaeometry a new technique was applied using a multi-sensor philosophy, which combines simultaneous measurement of pressure and temperature. This technology is innovative and complies with EN ISO 10693:2013, ASTM D4373-02(2007) and Soil Science Society of America standard test methods for calcium carbonate content in soils and sediments. The total carbonates analysis is based on a pressure method that utilizes the FOGII Digital Soil CalcimeterTM, which is a portable apparatus. The total carbonate content determined by treating a 1.000 g (+/- 0.001 g) dried sample specimens with 6N hydrochloric acid (HCL) reagent grade, in an enclosed reaction vessel. Carbon dioxide gas evolved during the reaction between the acid and carbonate fraction of the specimen, was measured by the resulting pressure generated, taking in account the temperature conditions during the reaction. Prior to analysis the procedure was validated with Sand/Soil mixtures from BIPEA proficiency testing program with soils of different origins. For applying this new method in archaeometry a total number of ten samples were used from various rocks which are related with cultural constructions and implements in Greece. They represent a large range of periods since the Neolithic times, and were selected because there was an uncertainty about their accurate mineralogical composition especially regarding the presence of carbonate minerals. The results were compared to the results from ELTRA CS580 inorganic carbon analyzer using an infrared cell. The determination of total carbonates for 10 samples from different ancient sites indicated a very good correlation (R2 >0.97) between the pressure method with temperature compensation and the infrared method. The proposed method is quickly and accurate in archaeometry and can replace easily other techniques for total carbonates testing. The FOGII Digital Soil CalcimeterTM is portable and easily can be carried for

  13. Investigation of the Unsteady Total Pressure Profile Corresponding to Counter-Rotating Vortices in an Internal Flow Application

    Science.gov (United States)

    Gordon, Kathryn; Morris, Scott; Jemcov, Aleksandar; Cameron, Joshua

    2013-11-01

    The interaction of components in a compressible, internal flow often results in unsteady interactions between the wakes and moving blades. A prime example in which this flow feature is of interest is the interaction between the downstream rotor blades in a transonic axial compressor with the wake vortices shed from the upstream inlet guide vane (IGV). Previous work shows that a double row of counter-rotating vortices convects downstream into the rotor passage as a result of the rotor blade bow shock impinging on the IGV. The rotor-relative time-mean total pressure distribution has a region of high total pressure corresponding to the pathline of the vortices. The present work focuses on the relationship between the magnitude of the time-mean rotor-relative total pressure profile and the axial spacing between the IGV and the rotor. A survey of different axial gap sizes is performed in a two-dimensional computational study to obtain the sensitivity of the pressure profile amplitude to IGV-rotor axial spacing.

  14. Pressure Pain Threshold as a Predictor of Acute Postoperative Pain Following Total Joint Arthroplasty.

    Science.gov (United States)

    Haghverdian, Brandon A; Wright, David J; Schwarzkopf, Ran

    2016-10-26

    Acute pain in the postoperative period after total joint arthroplasty (TJA) has a significant effect on early rehabilitation, hospital length of stay, and the development of chronic pain. Consequently, efforts have been made to predict the occurrence of postoperative pain using preoperative and intraoperative factors. In this study, we tested the usefulness of preoperative pressure pain threshold (PPT) values in the prediction of three outcomes for patients who underwent TJA: visual analog scale pain scores, hospital length of stay, and opioid consumption. Using a digital pressure algometer, we measured the preoperative PPT in 41 patients expected to undergo TJA at three different body sites: the first web space of the hand, the operative joint, and the contralateral joint. We correlated each PPT separately with postoperative visual analog scale pain scores, hospital length of stay, and opioid consumption. No significant correlation was found between preoperative PPT and the three postoperative outcomes. This finding held true when patients were subdivided by surgery type (total knee arthroplasty vs. total hip arthroplasty). There was no significant difference in PPT between the three body testing sites. This study failed to prove the usefulness of PPT in the prediction of acute postoperative pain, pain medication consumption, and length of stay. The pressure algometer has previously found a place in the assessment of pain in a variety of clinical settings, but its utility has not yet been demonstrated in patients undergoing TJA.

  15. Differences Between Men and Women with Total Laryngectomy

    Directory of Open Access Journals (Sweden)

    Bogdan Popescu

    2015-10-01

    Full Text Available The larynx is one of the organs that is usually involved in the tumor growth in the head and neck region and it is the second site of malignant neoplasia of the respiratory tract after the lungs. It is a wellknown fact that larynx cancer is more often present in male population, with a ratio of 3:1 male/female because of the higher rate of tobacco and alcohol use. The issues related to total laryngectomy are the loss of voice, swallowing rehabilitation, reeducation of breathing through the tracheostomy, psychological alterations and social pressure. Women tend to be more affected by the presence of the tracheostomy, since general physical aspect is a major concern for modern women. Also, the emotional status of women is a plays a major role for the adherence to the therapy plan. The response to total laryngectomy by men and women is similar with slight differences in physical aspect and social reinsertion.

  16. Changes of contact pressure and area in patellofemoral joint after different meniscectomies.

    Science.gov (United States)

    Bai, Bo; Shun, Hui; Yin, Zhi Xun; Liao, Zhuang-Wen; Chen, Ni

    2012-05-01

    We investigated the contact pressure and area of the patellofemoral joint both before and after different meniscectomies to provide a biomechanical basis for selecting meniscectomy and its clinical application for meniscus injuries. Six fresh cadaveric knees were used in the study. Using Staubli robots and an ultra-low-min-type pressure-sensitive tablet, changes in contact area and stress in the patellofemoral joint were measured at various flexion angles following different parts and degrees of meniscectomy. The patellofemoral contact area enlarged with the increase of knee flexion angle. From the values obtained from contact areas and average contact pressure of the patellofemoral joint, we found no significant difference between partial meniscectomy and intact knees, but a significant difference was found between total meniscectomy and intact knees. The contact area after lateral meniscectomy was statistically less than that of intact knees. The mean patellofemoral contact pressure after lateral meniscectomy was larger than in intact knees at each angle of flexion. No significant difference in contact area was observed between intact knees and medial meniscectomy. The average patellofemoral contact pressure after medial meniscectomy was larger than in intact knees from 0° ~ 30° of knee flexion, and no significant differences were found between intact knees and medial meniscectomy while knee bending from 60° to 90°. Different meniscectomies result in high contact pressure or disordered distribution of contact pressure, which may be the cause of postoperative patellofemoral degenerative arthrosis.

  17. Pressure sores following elective total hip arthroplasty: pitfalls of misinterpretation.

    Science.gov (United States)

    Keong, Nicole; Ricketts, David; Alakeson, Nuki; Rust, Philippa

    2004-01-01

    OBJECTIVE: To assess the reliability of reporting protocols regarding pressure sores. METHODS: Retrospective data were collected regarding pressure sore rates following total hip arthroplasty operations carried out during 2001 at two orthopaedic units in an NHS hospital (Princess Royal Hospital) and in a local private hospital. RESULTS: Preliminary results presented in audit and interim reports indicated an alarmingly high pressure sore rate across the two sites (17/172 [9.9%] NHS, 23/71 [32.4%] private hospital). On analysis, the data collection system was revealed to be flawed. Grade 1 areas (erythema with no ulceration) were included, leading to a dramatic discrepancy between reported and confirmed pressure sores. Re-analysis showed the confirmed pressure sore rates to be much lower (2.3% NHS, 1.0% private hospital). CONCLUSIONS: This audit suggests that both poor data collection and education lead to inaccurate audit. This may lead to subsequent inappropriate management and inappropriate NHS star ratings. PMID:15140301

  18. A total pressure-saturation formulation of two-phase flow incorporating dynamic effects in the capillary-pressure-saturation relationship

    Energy Technology Data Exchange (ETDEWEB)

    Dahle, H K; Celia, M A; Hassanizadeh, S M; Karlsen, K H

    2002-07-01

    New theories suggest that the relationship between capillary pressure and saturation should be enhanced by a dynamic term that is proportional to the time rate of change of saturation. This so-called dynamic capillary pressure formulation is supported by laboratory experiments, and can be included in various forms of the governing equations for two-phase flow in porous media. An extended model of two-phase flow in porous media may be developed based on fractional flow curves and a total pressure - saturation description that includes the dynamic capillary pressure terms. A dimensionless form of the resulting equation set provides an ideal tool to study the relative importance of the dynamic capillary pressure effect. This equation provides a rich set of mathematical research questions, and numerical solutions to the equation provide insights into the behavior of two-phase immiscible flow. For typical two-phase flow systems, dynamic capillary pressure acts to retard infiltration fronts, with responses dependent on system parameters including boundary conditions. Recent theoretical work suggests that the traditional algebraic relationship between capillary pressure and saturation may be inadequate. Instead, a so-called dynamic capillary pressure formulation is needed, where capillary pressure is defined as a thermodynamic variable, and the difference between phase pressures is only equal to the capillary pressure at equilibrium. Under dynamic conditions, the disequilibrium between phase-pressure differences and the capillary pressure is taken to be proportional to the time rate of change of saturation. A recent study by Hassanizadeh et al. presents experimental evidence, culled from the literature, to support this claim. Numerical simulations using dynamic pore-scale network models and upscaling also support the claim. Hassanizadeh et al. also presented numerical solutions for an enhanced version of Richards' equation that included the dynamic terms. A preliminary

  19. Inter-Arm Difference in Brachial Blood Pressure in the General Population of Koreans.

    Science.gov (United States)

    Song, Bo Mi; Kim, Hyeon Chang; Shim, Jee-Seon; Lee, Myung Ha; Choi, Dong Phil

    2016-05-01

    We investigated the inter-arm difference in blood pressure of the general Korean population to identify associated factors. A total of 806 participants aged 30 to 64 years without history of major cardiovascular disease were analyzed in this cross-sectional study. They participated in the Cardiovascular and Metabolic Disease Etiology Research Center cohort study that began in 2013. Brachial blood pressure was measured simultaneously for both arms using an automated oscillometric device equipped with two cuffs in seated position. After five minutes of rest, systolic blood pressure (SBP) and diastolic blood pressure (DBP) were measured three times. The average of the three measurements was used for analysis. Multivariate logistic regression models were used to identify factors associated with inter-arm differences in blood pressure. The mean inter-arm difference was 3.3 mmHg for SBP and 2.0 mmHg for DBP. Large inter-arm differences (≥10 mmHg) in SBP and in DBP were found in 3.7% and 0.9% of subjects, respectively. A large inter-arm difference in SBP was associated with mean SBP (p=0.002) and C-reactive protein (p=0.014) while a large inter-arm different in DBP was only associated with body mass index (p=0.015). Sex, age, and anti-hypertensive medication use were not associated with differences in inter-arm blood pressure. Large inter-arm difference in blood pressure is only present in a small portion of healthy Korean adults. Our findings suggest that high SBP, chronic inflammation, and obesity may be associated with larger difference in inter-arm blood pressure.

  20. Contralateral limb during total contact casting. A dynamic pressure and thermometric analysis.

    Science.gov (United States)

    Armstrong, D G; Liswood, P J; Todd, W F

    1995-12-01

    The authors draw attention to the importance of evaluation of the contralateral limb when treating unilateral sequelae secondary to distal symmetrical polyneuropathy. Plantar pressure measurements of the contralateral limb during total contact casting are reviewed. The results of thermometric evaluation before and after initiation of repetitive stress were reviewed. The results suggest that the patient walking in a total contact cast may experience a reduced focal pressure on the contralateral limb when compared with uncasted walking and three-point walking with crutches. Dermal thermometry may be a highly sensitive tool in evaluating even mild increases in repetitive stress. To explain this decrease in contralateral stress, the authors examine the features inherent to the total contact cast and propose the concept of proprioceptive stability.

  1. Evaluation of Pressure Generated by Resistors From Different Positive Expiratory Pressure Devices.

    Science.gov (United States)

    Fagevik Olsén, Monika; Carlsson, Maria; Olsén, Erik; Westerdahl, Elisabeth

    2015-10-01

    Breathing exercises with positive expiratory pressure (PEP) are used to improve pulmonary function and airway clearance. Different PEP devices are available, but there have been no studies that describe the pressure generated by different resistors. The purpose of this study was to compare pressures generated from the proprietary resistor components of 4 commercial flow-dependent PEP valves with all other parameters kept constant. Resistors from 4 flow-regulated PEP devices (Pep/Rmt system, Wellspect HealthCare; Pipe P breathing exerciser, Koo Medical Equipment; Mini-PEP, Philips Respironics [including resistors by Rüsch]; and 15-mm endo-adapter, VBM Medizintechnik) were tested randomly by a blinded tester at constant flows of 10 and 18 L/min from an external gas system. All resistors were tested 3 times. Resistors with a similar diameter produced statistically significant different pressures at the same flow. The differences were smaller when the flow was 10 L/min compared with 18 L/min. The differences were also smaller when the diameter of the resistor was increased. The pressures produced by the 4 resistors of the same size were all significantly different when measuring 1.5- and 2.0-mm resistors at a flow of 10 L/min and 2.0-mm resistors at a flow of 18 L/min (P < .001). There were no significant differences between any of the resistors when testing sizes of 4.5 and 5.0 mm at either flow. The Mini-PEP and adapter resistors gave the highest pressures. Pressures generated by the different proprietary resistor components of 4 commercial PEP devices were not comparable, even though the diameter of the resistors is reported to be the same. The pressures generated were significantly different, particularly when using small-diameter resistors at a high flow. Therefore, the resistors may not be interchangeable. This is important information for clinicians, particularly when considering PEP for patients who do not tolerate higher pressures. Copyright © 2015 by

  2. Comparative analysis of pain in patients who underwent total knee replacement regarding the tourniquet pressure

    Directory of Open Access Journals (Sweden)

    Marcos George de Souza Leão

    Full Text Available ABSTRACT OBJECTIVES: To evaluate through the visual analog scale (VAS the pain in patients undergoing total knee replacement (TKR with different pressures of the pneumatic tourniquet. METHODS: An observational, randomized, descriptive study on an analytical basis, with 60 patients who underwent TKR, divided into two groups, which were matched: a group where TKR was performed with tourniquet pressures of 350 mmHg (standard and the other with systolic blood pressure plus 100 mmHg (P + 100. These patients had their pain assessed by VAS at 48 h, and at the 5th and 15th days after procedure. Secondarily, the following were also measured: range of motion (ROM, complications, and blood drainage volume in each group; the data were subjected to statistical analysis. RESULTS: After data analysis, there was no statistical difference regarding the incidence of complications (p = 0.612, ROM (p = 0.202, bleeding after 24 and 48 h (p = 0.432 and p = 0.254 or in relation to VAS. No correlation was observed between time of ischemia compared to VAS and bleeding. CONCLUSIONS: The use of the pneumatic tourniquet pressure at 350 mmHg or systolic blood pressure plus 100 mmHg did not influence the pain, blood loss, ROM, and complications. Therefore the pressures at these levels are safe and do not change the surgery outcomes; the time of ischemia must be closely observed to avoid major complications.

  3. Contact stresses, pressure and area in a fixed-bearing total ankle replacement: a finite element analysis.

    Science.gov (United States)

    Martinelli, Nicolo; Baretta, Silvia; Pagano, Jenny; Bianchi, Alberto; Villa, Tomaso; Casaroli, Gloria; Galbusera, Fabio

    2017-11-25

    Mobile-bearing ankle implants with good clinical results continued to increase the popularity of total ankle arthroplasty to address endstage ankle osteoarthritis preserving joint movement. Alternative solutions used fixed-bearing designs, which increase stability and reduce the risk of bearing dislocation, but with a theoretical increase of contact stresses leading to a higher polyethylene wear. The purpose of this study was to investigate the contact stresses, pressure and area in the polyethylene component of a new total ankle replacement with a fixed-bearing design, using 3D finite element analysis. A three-dimensional finite element model of the Zimmer Trabecular Metal Total Ankle was developed and assembled based on computed tomography images. Three different sizes of the polyethylene insert were modeled, and a finite element analysis was conducted to investigate the contact pressure, the von Mises stresses and the contact area of the polyethylene component during the stance phase of the gait cycle. The peak value of pressure was found in the anterior region of the articulating surface, where it reached 19.8 MPa at 40% of the gait cycle. The average contact pressure during the stance phase was 6.9 MPa. The maximum von Mises stress of 14.1 MPa was reached at 40% of the gait cycle in the anterior section. In the central section, the maximum von Mises stress of 10.8 MPa was reached at 37% of the gait cycle, whereas in the posterior section the maximum stress of 5.4 MPa was reached at the end of the stance phase. The new fixed-bearing total ankle replacement showed a safe mechanical behavior and many clinical advantages. However, advanced models to quantitatively estimate the wear are need. To the light of the clinical advantages, we conclude that the presented prosthesis is a good alternative to the other products present in the market.

  4. Inter-arm blood pressure difference in type 2 diabetes: a barrier to effective management?

    Science.gov (United States)

    Clark, Christopher E; Greaves, Colin J; Evans, Philip H; Dickens, Andy; Campbell, John L

    2009-06-01

    Previous studies have identified a substantial prevalence of a blood pressure difference between arms in various populations, but not patients with type 2 diabetes. Recognition of such a difference would be important as a potential cause of underestimation of blood pressure. To measure prevalence of an inter-arm blood pressure difference in patients with type 2 diabetes, and to estimate how frequently blood pressure measurements could be erroneously underestimated if an inter-arm difference is unrecognised. Cross-sectional study. Five surgeries covered by three general practices, Devon, England. Patients with type 2 diabetes underwent bilateral simultaneous blood pressure measurements using a validated protocol. Mean blood pressures were calculated for each arm to derive mean systolic and diastolic differences, and to estimate point prevalence of predefined magnitudes of difference. A total of 101 participants were recruited. Mean age was 66 years (standard deviation [SD] = 13.9 years); 59% were male, and mean blood pressure was 138/79 mmHg (SD = 15/10 mmHg). Ten participants (10%; 95% confidence interval [CI] = 4 to 16) had a systolic inter-arm difference > or =10 mmHg; 29 (29%; 95% CI = 20 to 38) had a diastolic difference >/=5 mmHg; and three (3%; 95% CI = 0 to 6) a diastolic difference > or =10 mmHg. No confounding variable was observed to account for the magnitude of an inter-arm difference. A systolic inter-arm difference > or =10 mmHg was observed in 10% of patients with diabetes. Failure to recognise this would misclassify half of these as normotensive rather than hypertensive using the lower-reading arm. New patients with type 2 diabetes should be screened for an inter-arm blood pressure difference.

  5. Dependency of radon entry on pressure difference

    International Nuclear Information System (INIS)

    Kokotti, H.; Kalliokoski, P.

    1992-01-01

    Radon levels, ventilation rate and pressure differences were monitored continuously in four apartment houses with different ventilation systems. Two of them were ventilated by mechanical exhaust, one by mechanical supply and exhaust, and one by natural ventilation. The two-storey houses were constructed from concrete elements on a slab and located on a gravel esker. It was surprising to find that increasing the ventilation rate increased levels of radon in the apartments. Increased ventilation caused increased outdoor-indoor pressure difference, which in turn increased the entry rate of radon and counteracted the diluting effect of ventilation. The increase was significant when the outdoor-indoor pressure difference exceeded 5 Pa. Especially in the houses with mechanical exhaust ventilation the pressure difference was the most important factor of radon entry rate, and contributed up to several hundred Bq m -3 h -1 . (Author)

  6. Total dissolved gas, barometric pressure, and water temperature data, lower Columbia River, Oregon and Washington, 1996

    Science.gov (United States)

    Tanner, Dwight Q.; Harrison, Howard E.; McKenzie, Stuart W.

    1996-01-01

    Increased levels of total dissolved gas pressure can cause gas-bubble trauma in fish downstream from dams on the Columbia River. In cooperation with the U.S. Army Corps of Engineers, the U.S. Geological Survey collected data on total dissolved gas pressure, barometric pressure, water temperature, and dissolved oxygen pressure at 11 stations on the lower Columbia River from the John Day forebay (river mile 215.6) to Wauna Mill (river mile 41.9) from March to September 1996. Methods of data collection, review, and processing are described in this report. Summaries of daily minimum, maximum, and mean hourly values are presented for total dissolved gas pressure, barometric pressure, and water temperature. Hourly values for these parameters are presented graphically. Dissolved oxygen data are not presented in this report because the quality-control data show that the data have poor precision and high bias. Suggested changes to monitoring procedures for future studies include (1) improved calibration procedures for total dissolved gas and dissolved oxygen to better define accuracy at elevated levels of supersaturation and (2) equipping dissolved oxygen sensors with stirrers because river velocities at the shoreline monitoring stations probably cannot maintain an adequate flow of water across the membrane surface of the dissolved oxygen sensor.

  7. Interarm difference in blood pressure

    DEFF Research Database (Denmark)

    Mehlsen, Jesper; Wiinberg, Niels

    2014-01-01

    The present study aimed at examining the interarm difference in blood pressure and its use as an indicator of peripheral arterial disease (PAD). Data were included from consecutive patients referred from their general practitioner to our vascular laboratory for possible PAD aged 50 years or older...... without known cardiac disease, renal disease, or diabetes mellitus. 824 patients (453 women) with mean age of 72 years (range: 50-101) were included. 491 patients had a diagnosis of hypertension and peripheral arterial disease (PAD) was present in 386 patients. Systolic blood pressure was 143 ± 24 mm......Hg and 142 ± 24 mmHg on the right and left arm, respectively (P = 0.015). The interarm difference was greater in patients with hypertension (P = 0.002) and PAD (P blood pressure was reproducible...

  8. Equilibrium Total Pressure and CO2 Solubility in Binary and Ternary Aqueous Solutions of 2-(Diethylamino)ethanol (DEEA) and 3-(Methylamino)propylamine (MAPA)

    DEFF Research Database (Denmark)

    Waseem Arshad, Muhammad; Svendsen, Hallvard Fjøsne; Fosbøl, Philip Loldrup

    2014-01-01

    Equilibrium total pressures were measured and equilibrium CO2 partial pressures were calculated from the measured total pressure data in binary and ternary aqueous solutions of 2-(diethylamino)ethanol (DEEA) and 3-(methylamino)propylamine (MAPA). The measurements were carried out in a commercially...... available calorimeter used as an equilibrium cell. The examined systems were the binary aqueous solutions of 5 M DEEA, 2 M MAPA, and 1 M MAPA and the ternary aqueous mixtures of 5 M DEEA + 2 M MAPA (5D2M) and 5 M DEEA + 1 M MAPA (5D1M), which gave liquid–liquid phase split upon CO2 absorption. The total...... pressures were measured and the CO2 partial pressures were calculated as a function of CO2 loading at three different temperatures 40 °C, 80 °C, and 120 °C. All experiments were reproduced with good repeatability. The measurements were carried out for 30 mass % MEA solutions to validate the experimental...

  9. Optimum pressure for total-reflux operated thermal diffusion column for isotope separation

    International Nuclear Information System (INIS)

    Yamamoto, Ichiro; Makino, Hitoshi; Kanagawa, Akira

    1990-01-01

    A formula for prediction of the optimum operating pressure P opt of the thermal diffusion columns at total reflux is derived based on the approximate formulae for the column constants which can be evaluated analytically. The formula is expressed explicitly in terms of (1) physical properties of gases to be separated, (2) ratio of radii between hot wire and cold wall of the column, and (3) the ratio of the temperature difference to the cold wall temperature. The result is compared with experimental data; (1) binary monatomic gas systems, (2) multicomponent monatomic gas systems, (3) isotopically substituted polyatomic systems, (4) systems of low atomic or molecular weight, and (5) mixtures of unlike gases; mainly obtained by Rutherford and coworkers. Although the formula is based on the rather rough approximation for the column constants, the optimum pressures predicted by the present formula are in successfully good agreement with the experimental data even for the systems of low atomic or molecular weight and that of mixtures of unlike gases. (author)

  10. Assessment of plantar pressure in forefoot relief shoes of different designs.

    Science.gov (United States)

    Carl, Hans-Dieter; Pfander, David; Swoboda, Bernd

    2006-02-01

    After reconstructive forefoot surgery, patients require complete or partial forefoot relief, which can be obtained with a variety of shoe designs. The aim of this study was to evaluate the effectiveness of two different types of forefoot-relief shoes frequently used after surgery, especially their safety against unintentional forefoot load. Ten healthy volunteers were asked to perform five trials on a treadmill at self-selected speeds. In the first trial, mean peak pressure values in mass-produced shoes and insoles were evaluated and considered as 100%. Two different shoe designs (short heel-short sole, ii: short heel-complete sole) were compared in two trials each with appropriate and inappropriate use (attempting to put weight on the forefoot) gait pattern. Plantar pressure values were obtained using the Pedar cable system (Novel Inc., Munich, Germany). For analysis, pedobarographic pictures were subdivided into midfoot (31% to 60% of the total insole length) and forefoot (61% to 100% of the total insole length). ANOVA was used for statistical analysis, and p values less than 0.01 were considered significant. With the short-soled shoe, forefoot and midfoot relief was 100% in both compliant and in noncompliant use. With wearing a complete sole, compliant use led to a significant reduction (p shoe produced mean peak pressure values significantly higher (p shoes under the forefoot, but not under the midfoot. Forefoot-relief shoes are effective in reducing both mean and peak plantar pressures. Shoes with a nonsupported midfoot and forefoot may be safer with inappropriate use than shoes with a complete sole. The kind of forefoot shoe should be carefully chosen to regulate weightbearing after reconstructive forefoot surgery.

  11. Estimated Trans-Lamina Cribrosa Pressure Differences in Low-Teen and High-Teen Intraocular Pressure Normal Tension Glaucoma: The Korean National Health and Nutrition Examination Survey

    OpenAIRE

    Lee, Si Hyung; Kwak, Seung Woo; Kang, Eun Min; Kim, Gyu Ah; Lee, Sang Yeop; Bae, Hyoung Won; Seong, Gong Je; Kim, Chan Yun

    2016-01-01

    Background To investigate the association between estimated trans-lamina cribrosa pressure difference (TLCPD) and prevalence of normal tension glaucoma (NTG) with low-teen and high-teen intraocular pressure (IOP) using a population-based study design. Methods A total of 12,743 adults (? 40 years of age) who participated in the Korean National Health and Nutrition Examination Survey (KNHANES) from 2009 to 2012 were included. Using a previously developed formula, cerebrospinal fluid pressure (C...

  12. Benefits of Sleep Extension on Sustained Attention and Sleep Pressure Before and During Total Sleep Deprivation and Recovery.

    Science.gov (United States)

    Arnal, Pierrick J; Sauvet, Fabien; Leger, Damien; van Beers, Pascal; Bayon, Virginie; Bougard, Clément; Rabat, Arnaud; Millet, Guillaume Y; Chennaoui, Mounir

    2015-12-01

    To investigate the effects of 6 nights of sleep extension on sustained attention and sleep pressure before and during total sleep deprivation and after a subsequent recovery sleep. Subjects participated in two experimental conditions (randomized cross-over design): extended sleep (EXT, 9.8 ± 0.1 h (mean ± SE) time in bed) and habitual sleep (HAB, 8.2 ± 0.1 h time in bed). In each condition, subjects performed two consecutive phases: (1) 6 nights of either EXT or HAB (2) three days in-laboratory: baseline, total sleep deprivation and after 10 h of recovery sleep. Residential sleep extension and sleep performance laboratory (continuous polysomnographic recording). 14 healthy men (age range: 26-37 years). EXT vs. HAB sleep durations prior to total sleep deprivation. Total sleep time and duration of all sleep stages during the 6 nights were significantly higher in EXT than HAB. EXT improved psychomotor vigilance task performance (PVT, both fewer lapses and faster speed) and reduced sleep pressure as evidenced by longer multiple sleep latencies (MSLT) at baseline compared to HAB. EXT limited PVT lapses and the number of involuntary microsleeps during total sleep deprivation. Differences in PVT lapses and speed and MSLT at baseline were maintained after one night of recovery sleep. Six nights of extended sleep improve sustained attention and reduce sleep pressure. Sleep extension also protects against psychomotor vigilance task lapses and microsleep degradation during total sleep deprivation. These beneficial effects persist after one night of recovery sleep. © 2015 Associated Professional Sleep Societies, LLC.

  13. Exploring the relationship of peripheral total bilirubin, red blood cell, and hemoglobin with blood pressure during childhood and adolescence.

    Science.gov (United States)

    Chen, Xiao-Tian; Yang, Song; Yang, Ya-Ming; Zhao, Hai-Long; Chen, Yan-Chun; Zhao, Xiang-Hai; Wen, Jin-Bo; Tian, Yuan-Rui; Yan, Wei-Li; Shen, Chong

    2017-11-04

    Total bilirubin is beneficial for protecting cardiovascular diseases in adults. The authors aimed to investigate the association of total bilirubin, red blood cell, and hemoglobin levels with the prevalence of high blood pressure in children and adolescents. A total of 3776 students (aged from 6 to 16 years old) were examined using cluster sampling. Pre-high blood pressure and high blood pressure were respectively defined as the point of 90th and 95th percentiles based on the Fourth Report on the Diagnosis, Evaluation, and Treatment of High Blood Pressure in Children and Adolescents. Both systolic and diastolic blood pressure were standardized into z-scores. Peripheral total bilirubin, red blood cell and hemoglobin levels were significantly correlated with age, and also varied with gender. Peripheral total bilirubin was negatively correlated with systolic blood pressure in 6- and 9-year-old boys, whilst positively correlated with diastolic blood pressure in the 12-year-old boys and 13- to 15-year-old girls (p0.05). Total bilirubin could be weakly correlated with both systolic and diastolic blood pressure, as correlations varied with age and gender in children and adolescents; in turn, the increased levels of red blood cell and hemoglobin are proposed to be positively associated with the prevalence of high blood pressure. Copyright © 2017 Sociedade Brasileira de Pediatria. Published by Elsevier Editora Ltda. All rights reserved.

  14. Cerebrospinal Fluid Amyloid-β 42, Total Tau and Phosphorylated Tau are Low in Patients with Normal Pressure Hydrocephalus: Analogies and Differences with Alzheimer's Disease.

    Science.gov (United States)

    Santangelo, Roberto; Cecchetti, Giordano; Bernasconi, Maria Paola; Cardamone, Rosalinda; Barbieri, Alessandra; Pinto, Patrizia; Passerini, Gabriella; Scomazzoni, Francesco; Comi, Giancarlo; Magnani, Giuseppe

    2017-01-01

    Co-existence of Alzheimer's disease (AD) in normal pressure hydrocephalus (NPH) is a frequent finding, thus a common pathophysiological basis between AD and NPH has been postulated. We measured CSF amyloid-β 42 (Aβ42), total tau (t-tau), and phosphorylated tau (p-tau) concentrations in a sample of 294 patients with different types of dementia and 32 subjects without dementia. We then compared scores on neuropsychological tests of NPH patients with pathological and normal CSF Aβ42 values. Aβ42 levels were significantly lower in NPH than in control patients, with no significant differences between AD and NPH. On the contrary, t-tau and p-tau levels were significantly lower in NPH than in AD, with no differences between NPH and controls. NPH patients with pathological Aβ42 levels did not perform worse than NPH patients with normal Aβ42 levels in any cognitive domains. Our data seem to support the hypothesis of amyloid accumulation in brains of NPH patients. Nevertheless, amyloid does not seem to play a pathogenetic role in the development of cognitive deficits in NPH.

  15. Inter-arm blood pressure difference in hospitalized elderly patients--is it consistent?

    Science.gov (United States)

    Grossman, Alon; Weiss, Avraham; Beloosesky, Yichayaou; Morag-Koren, Nira; Green, Hefziba; Grossman, Ehud

    2014-07-01

    Inter-arm blood pressure difference (IAD) is recognized as a risk factor for cardiovascular mortality. Its reproducibility in the elderly is unknown. The authors determined the prevalence and reproducibility of IAD in hospitalized elderly patients. Blood pressure was measured simultaneously in both arms on two different days in elderly individuals hospitalized in a geriatric ward. The study included 364 elderly patients (mean age, 85±5 years). Eighty-four patients (23%) had systolic IAD >10 and 62 patients (17%) had diastolic IAD >10 mm Hg. A total of 319 patients had two blood pressure measurements. Systolic and diastolic IAD remained in the same category in 203 (64%) and 231 (72%) patients, respectively. Correlations of systolic and diastolic IAD between the two measurements were poor. Consistency was not affected by age, body mass index, comorbidities, or treatment. IAD is extremely common in hospitalized elderly patients, but, because of poor consistency, its clinical significance in this population is uncertain. ©2014 Wiley Periodicals, Inc.

  16. Total Artificial Heart Implantation Blood Pressure Management as Resolving Treatment for Massive Hemolysis following Total Artificial Heart Implantation.

    Science.gov (United States)

    Ghodsizad, Ali; Koerner, Michael M; El-Banayosy, A; Zeriouh, Mohamed; Ruhparwar, Arjang; Loebe, Matthias

    2016-10-21

    The SynCardia Total Artificial Heart (TAH) has been used for patients with biventricular failure, who cannot be managed with implantation of a left ventricular (LV) assist device. Following TAH implantation, our patient developed severe hemolysis, which could only be managed successfully by aggressive blood pressure control [Ohashi 2003; Nakata 1998].

  17. Flashing evaporation under different pressure levels

    International Nuclear Information System (INIS)

    Liao, Yixiang; Lucas, Dirk; Krepper, Eckhard; Rzehak, Roland

    2013-01-01

    Highlights: • CFD simulation based on two-fluid model for flashing boiling inside a vertical pipe. • Effect of pressure level on the maximum thermal energy available for evaporation. • Effect of presumed bubble size on the onset of flashing as well as evaporation rate. • Effect of pressure level on the critical bubble size that can start stable flashing. • Effect of pressure level on nucleation rate and mechanism. - Abstract: Flashing evaporation of water inside a vertical pipe under four pressure levels is investigated both experimentally and numerically. In the experiment depressurization is realized through a blow-off valve, and the evaporation rate is controlled by the opening rate and degree of the valve. In the CFD simulation phase change is assumed to be caused by thermal heat transfer between steam–water interface and the surrounding water. Consequently, the evaporation rate is determined by heat transfer coefficient, interfacial area density as well as liquid superheat degree. The simulated temporal course of cross-section averaged steam volume fraction is compared with the measured one. It is found that the increasing rate and maximum value of steam volume fraction is over-predicted under low-pressure conditions, which is mainly caused by the neglect of bubble growth in the mono-dispersed simulation. The agreement is notably improved by performing poly-dispersed simulations with the inhomogeneous MUSIG approach (IMUSIG). On the other hand an underestimation of the maximum steam volume fraction is observed in high-pressure cases, since the contribution of nucleation to the total steam generation rate becomes large as the system pressure increases. Reliable models for nucleation rate as well as bubble detachment size are indispensable for reliable predictions. An effect of the system pressure level on the nucleation mechanism is observed in the experiment

  18. Predicting mass loading as a function of pressure difference across prefilter/HEPA filter systems

    International Nuclear Information System (INIS)

    Novick, V.J.; Klassen, J.F.; Monson, P.R.

    1992-01-01

    The purpose of this work is to develop a methodology for predicting the mass loading and pressure drop effects on a prefilter/ HEPA filter system. The methodology relies on the use of empirical equations for the specific resistance of the aerosol loaded filter as a function of the particle diameter. These correlations relate the pressure difference across a filter to the mass loading on the filter and accounts for aerosol particle density effects. These predictions are necessary for the efficient design of new filtration systems and for risk assessment studies of existing filter systems. This work specifically addresses the prefilter/HEPA filter Airborne Activity Confinement Systems (AACS) at the Savannah River Plant. In order to determine the mass loading on the system, it is necessary to establish the efficiency characteristics for the prefilter, the mass loading characteristics of the prefilter measured as a function of pressure difference across the prefilter, and the mass loading characteristics of the HEPA filter as a function of pressure difference across the filter. Furthermore, the efficiency and mass loading characteristics need to be determined as a function of the aerosol particle diameter. A review of the literature revealed that no previous work had been performed to characterize the prefilter material of interest. In order to complete the foundation of information necessary to predict total mass loadings on prefilter/HEPA filter systems, it was necessary to determine the prefilter efficiency and mass loading characteristics. The measured prefilter characteristics combined with the previously determined HEPA filter characteristics allowed the resulting pressure difference across both filters to be predicted as a function of total particle mass for a given particle distribution. These predictions compare favorably to experimental measurements (±25%)

  19. Measuring and understanding total dissolved gas pressure in groundwater

    Science.gov (United States)

    Ryan, C.; Roy, J. W.; Randell, J.; Castellon, L.

    2009-05-01

    Since dissolved gases are important to a number of aspects of groundwater (e.g. age dating, active or passive bioremediation, greenhouse gas fluxes, understanding biogeochemical processes involving gases, assessing potential impacts of coal bed methane activities), accurate concentration measurements, and understanding of their subsurface behaviour are important. Researchers have recently begun using total dissolved gas pressure (TGP) sensor measurements, more commonly applied for surface water monitoring, in concert with gas composition analyses to estimate more accurate groundwater gas concentrations in wells. We have used hydraulic packers to isolate the well screens where TDP is being measured, and pump tests to indicate that in-well degassing may reduce TDG below background groundwater levels. Thus, in gas-charged groundwater zones, TGPs can be considerably underestimated in the absence of pumping or screen isolation. We have also observed transient decreased TGPs during pumping that are thought to result from ebullition induced when the water table or water level in the well is lowered below a critical hydrostatic pressure.

  20. Pressure-modulation dynamic attenuated-total-reflectance (ATR) FT-IR spectroscopy

    Science.gov (United States)

    Marcott, C.; Story, G. M.; Noda, I.; Bibby, A.; Manning, C. J.

    1998-06-01

    A single-reflectance attenuated-total-reflectance (ATR) accessory with a diamond internal-reflection element was modified by the addition of a piezoelectric transducer. Initial dynamic pressure-modulation experiments have been performed in the sample compartment of a step-scanning FT-IR spectrometer. A sinusoidal pressure modulation applied to samples of isotactic polypropylene and linear low density polyethylene resulted in dynamic responses which appear to be similar to those observed in previous dynamic 2D IR experiments. Preliminary pressure-modulation dynamic ATR results are also reported for a styrene-butadiene-styrene triblock copolymer. The new method has the advantages that a much wider variety of sample types and geometries can be studied and less sample preparation is required. Dynamic 2D IR experiments carried out by ATR no longer require thin films of large area and sufficient strength to withstand the dynamic strain applied by a rheometer. The ability to obtain dynamic IR spectroscopic information from a wider variety of sample types and thicknesses would greatly expand the amount of useful information that could be extracted from normally complicated, highly overlapped IR spectra.

  1. The roles of different salts and a novel osmotic pressure control strategy for improvement of DHA production by Schizochytrium sp.

    Science.gov (United States)

    Hu, Xue-Chao; Ren, Lu-Jing; Chen, Sheng-Lan; Zhang, Li; Ji, Xiao-Jun; Huang, He

    2015-11-01

    The effects of different osmotic pressure, changed by six salts (NaCl, Na2SO4, (NH4)2SO4, KH2PO4 and MSG), on cell growth and DHA synthesis by Schizochytrium sp. were investigated. Six optimal mediums were obtained to study different osmotic pressure combinations at cell growth stage and DHA synthesis stage. Results showed that cultivated cell in higher osmotic pressure condition and fermented in lower osmotic pressure condition was benefit to enhance DHA synthesis. Combination 17-6 could get the maximum cell dry weight of 56.95 g/L and the highest DHA percentage in total fatty acids of 55.21%, while combination 17-B could get the highest lipid yield of 33.47 g/L with 42.10% DHA in total fatty acids. This was the first report about the enhancement of DHA production by osmotic regulation and this work provided two novel osmotic control processes for high lipid yield and high DHA percentage in total fatty acids.

  2. Research experiments on pressure-difference sensors with ferrofluid

    Energy Technology Data Exchange (ETDEWEB)

    Ruican, Hao, E-mail: haoruican@163.com [School of Mechanical Engineering, Beijing Polytechnic, Beijing 100176 (China); Huagang, Liu; Wen, Gong; Na, Zhang [School of Mechanical Engineering, Beijing Polytechnic, Beijing 100176 (China); Ruixiao, Hao [Civil and Architectural Engineering Institute of CCCC-FHEB Co., Ltd., Beijing 101102 (China)

    2016-10-15

    Ferrofluid has distinctive properties and can be applied in many industrial uses, especially in sensors. The principles of pressure-difference sensors with ferrofluid were illustrated and experiments were demonstrated. Four types of ferrofluids with different concentrations were selected for the experiments performed. Then, the parameters of ferrofluid, such as density and magnetization, were measured. The magnetization curves of the ferrofluid were sketched. Four U tubes with different diameters were designed and built. Experiments were conducted to analyze the impacts of tube diameter and ferrofluid concentration on the output voltage/pressure difference performance. According to the experiment results, the tube diameter has little effect on the sensor output voltage. With the concentration of ferrofluid increasing, the output voltage and sensitivity of the pressure-difference sensor increases. The measurable range of the sensor also increases with the increasing concentration of ferrofluid. The workable range and the sensitivity of the designed sensor were (−2000~+2000)Pa and 1.26 mV/Pa, respectively. - Highlights: • The principle of pressure difference sensor with ferrofluid was illustrated. • The parameters of ferrofluid, such as density and magnetization, were measured. The magnetization curves of the ferrofluid were sketched. • Four series of U tubes with different diameter were designed and manufactured. • The experiments were made to analyze the factors of the tube diameter and the concentration of ferrofluid on the output-input pressure difference. • The sensitivity of the pressure difference sensor with ferrofluid was studied and the corresponding conclusions were obtained.

  3. Research experiments on pressure-difference sensors with ferrofluid

    International Nuclear Information System (INIS)

    Ruican, Hao; Huagang, Liu; Wen, Gong; Na, Zhang; Ruixiao, Hao

    2016-01-01

    Ferrofluid has distinctive properties and can be applied in many industrial uses, especially in sensors. The principles of pressure-difference sensors with ferrofluid were illustrated and experiments were demonstrated. Four types of ferrofluids with different concentrations were selected for the experiments performed. Then, the parameters of ferrofluid, such as density and magnetization, were measured. The magnetization curves of the ferrofluid were sketched. Four U tubes with different diameters were designed and built. Experiments were conducted to analyze the impacts of tube diameter and ferrofluid concentration on the output voltage/pressure difference performance. According to the experiment results, the tube diameter has little effect on the sensor output voltage. With the concentration of ferrofluid increasing, the output voltage and sensitivity of the pressure-difference sensor increases. The measurable range of the sensor also increases with the increasing concentration of ferrofluid. The workable range and the sensitivity of the designed sensor were (−2000~+2000)Pa and 1.26 mV/Pa, respectively. - Highlights: • The principle of pressure difference sensor with ferrofluid was illustrated. • The parameters of ferrofluid, such as density and magnetization, were measured. The magnetization curves of the ferrofluid were sketched. • Four series of U tubes with different diameter were designed and manufactured. • The experiments were made to analyze the factors of the tube diameter and the concentration of ferrofluid on the output-input pressure difference. • The sensitivity of the pressure difference sensor with ferrofluid was studied and the corresponding conclusions were obtained.

  4. The systolic blood pressure difference between arms and cardiovascular disease in the Framingham Heart Study.

    Science.gov (United States)

    Weinberg, Ido; Gona, Philimon; O'Donnell, Christopher J; Jaff, Michael R; Murabito, Joanne M

    2014-03-01

    An increased interarm systolic blood pressure difference is an easily determined physical examination finding. The relationship between interarm systolic blood pressure difference and risk of future cardiovascular disease is uncertain. We described the prevalence and risk factor correlates of interarm systolic blood pressure difference in the Framingham Heart Study (FHS) original and offspring cohorts and examined the association between interarm systolic blood pressure difference and incident cardiovascular disease and all-cause mortality. An increased interarm systolic blood pressure difference was defined as ≥ 10 mm Hg using the average of initial and repeat blood pressure measurements obtained in both arms. Participants were followed through 2010 for incident cardiovascular disease events. Multivariable Cox proportional hazards regression analyses were performed to investigate the effect of interarm systolic blood pressure difference on incident cardiovascular disease. We examined 3390 (56.3% female) participants aged 40 years and older, free of cardiovascular disease at baseline, mean age of 61.1 years, who attended a FHS examination between 1991 and 1994 (original cohort) and from 1995 to 1998 (offspring cohort). The mean absolute interarm systolic blood pressure difference was 4.6 mm Hg (range 0-78). Increased interarm systolic blood pressure difference was present in 317 (9.4%) participants. The median follow-up time was 13.3 years, during which time 598 participants (17.6%) experienced a first cardiovascular event, including 83 (26.2%) participants with interarm systolic blood pressure difference ≥ 10 mm Hg. Compared with those with normal interarm systolic blood pressure difference, participants with an elevated interarm systolic blood pressure difference were older (63.0 years vs 60.9 years), had a greater prevalence of diabetes mellitus (13.3% vs 7.5%,), higher systolic blood pressure (136.3 mm Hg vs 129.3 mm Hg), and a higher total cholesterol

  5. Total dose radiation effects of pressure sensors fabricated on uni-bond-SOI materials

    International Nuclear Information System (INIS)

    Zhu Shiyang; Huang Yiping; Wang Jin; Li Anzhen; Shen Shaoqun; Bao Minhang

    2001-01-01

    Piezoresistive pressure sensors with a twin-island structure were successfully fabricated using high quality Uni-bond-SOI (On Insulator) materials. Since the piezoresistors were structured by the single crystalline silicon overlayer of the SOI wafer and were totally isolated by the buried SiO 2 , the sensors are radiation-hard. The sensitivity and the linearity of the pressure sensors keep their original values after being irradiated by 60 Co γ-rays up to 2.3 x 10 4 Gy(H 2 O). However, the offset voltage of the sensor has a slight drift, increasing with the radiation dose. The absolute value of the offset voltage deviation depends on the pressure sensor itself. For comparison, corresponding polysilicon pressure sensors were fabricated using the similar process and irradiated at the same condition

  6. Variation with Mach Number of Static and Total Pressures Through Various Screens

    Science.gov (United States)

    Adler, Alfred A

    1946-01-01

    Tests were conducted in the Langley 24-inch highspeed tunnel to ascertain the static-pressure and total-pressure losses through screens ranging in mesh from 3 to 12 wires per inch and in wire diameter from 0.023 to 0.041 inch. Data were obtained from a Mach number of approximately 0.20 up to the maximum (choking) Mach number obtainable for each screen. The results of this investigation indicate that the pressure losses increase with increasing Mach number until the choking Mach number, which can be computed, is reached. Since choking imposes a restriction on the mass rate of flow and maximum losses are incurred at this condition, great care must be taken in selecting the screen mesh and wire dimmeter for an installation so that the choking Mach number is

  7. Temperature and Pressure Evolution during Al Alloy Solidification at Different Squeeze Pressures

    International Nuclear Information System (INIS)

    Li, Junwen; Zhao, Haidong; Chen, Zhenming

    2015-01-01

    Squeeze casting is an advanced and near net-shape casting process, in which external high pressure is applied to solidifying castings. The castings are characterized with fine grains and good mechanical properties. In this study, a series of experiments were carried out to measure the temperature and pressure histories in cavity of Al-Si-Mg direct squeeze castings with different applied solidification pressures of 0.1, 50, 75, and 100 MPa. The evolution of the measured temperatures and pressures was compared and discussed. The effect of pressure change on formation of shrinkage defects was analyzed. Further the friction between the castings and dies during solidification was calculated. It is shown that the applied squeeze pressure has significant influence on the friction at die and casting interfaces, which affects the pressure evolution and transmission. The results could provide some benchmark data for future thermal-mechanics coupled modeling of squeeze castings. (paper)

  8. Influence of Total Knee Arthroplasty on Patellar Kinematics and Patellofemoral Pressure.

    Science.gov (United States)

    Tanikawa, Hidenori; Tada, Mitsunori; Harato, Kengo; Okuma, Kazunari; Nagura, Takeo

    2017-01-01

    Patellofemoral complications are one of the main problems after total knee arthroplasty (TKA). The design of the TKA component may affect the patellar biomechanics, which may be associated with this postoperative complication. The purpose of this study was to assess the influence of TKA and prosthesis designs on the patellar kinematics and patellofemoral pressure. Using fresh-frozen cadavers, we measured the patellofemoral pressure, patella offset, and patella tilt in the following 4 conditions: normal knee (patella replacement only), cruciate-retaining TKA, condylar-stabilizing TKA, and posterior-stabilized TKA. The patellofemoral pressure increased significantly after the cruciate-retaining TKA and condylar-stabilizing TKA compared with the normal knee. The patella offset in the normal knee decreased with increasing knee flexion angles, while the patella offset in the TKA knees did not change significantly through the full range of motion. The amount of lateral patella tilt in the normal knee was significantly larger than the TKA knees in the full range of motion. Although the femoral components are designed to reproduce an anatomical patellar tracking, the physiological patellar kinematics were not observed. Relatively high patellofemoral pressure and kinematic change after TKA may be associated with postoperative complications such as the anterior knee pain. Copyright © 2016 Elsevier Inc. All rights reserved.

  9. Medial stabilized and posterior stabilized TKA affect patellofemoral kinematics and retropatellar pressure distribution differently.

    Science.gov (United States)

    Glogaza, Alexander; Schröder, Christian; Woiczinski, Matthias; Müller, Peter; Jansson, Volkmar; Steinbrück, Arnd

    2018-06-01

    Patellofemoral kinematics and retropatellar pressure distribution change after total knee arthroplasty (TKA). It was hypothesized that different TKA designs will show altered retropatellar pressure distribution patterns and different patellofemoral kinematics according to their design characteristics. Twelve fresh-frozen knee specimens were tested dynamically in a knee rig. Each specimen was measured native, after TKA with a posterior stabilized design (PS) and after TKA with a medial stabilized design (MS). Retropatellar pressure distribution was measured using a pressure sensitive foil which was subdivided into three areas (lateral and medial facet and patellar ridge). Patellofemoral kinematics were measured by an ultrasonic-based three-dimensional motion system (Zebris CMS20, Isny Germany). Significant changes in patellofemoral kinematics and retropatellar pressure distribution were found in both TKA types when compared to the native situation. Mean retropatellar contact areas were significantly smaller after TKA (native: 241.1 ± 75.6 mm 2 , MS: 197.7 ± 74.5 mm 2 , PS: 181.2 ± 56.7 mm 2 , native vs. MS p patellofemoral kinematics were found in both TKA designs when compared to the native knee during flexion and extension with a more medial patella tracking. Patellofemoral kinematics and retropatellar pressure change after TKA in different manner depending on the type of TKA used. Surgeons should be aware of influencing the risks of patellofermoral complications by the choice of the prosthesis design.

  10. Blood pressure reduction induced by low dose of epinephrine via different routes in rats.

    Science.gov (United States)

    Wu, Jing; Ji, Mu-Huo; Wang, Zhong-Yun; Zhu, Wei; Yang, Jian-Jun; Peng, Yong G

    2013-09-01

    Epinephrine was recently shown to induce a hypotension episode. Activation of β₂-adrenoceptors with smooth muscle relaxation may be the underlying mechanism. This study investigated the effects of ICI 118551, a β₂-adrenoceptors antagonist, on epinephrine-induced blood pressure reduction via different administration routes in rats. A total of 144 Sprague Dawley rats were equally randomized into 3 groups (intranasal, intravenous, and intra-arterial administration), each with 4 subgroups: saline + saline, ICI 118551 + saline, saline + epinephrine, and ICI 118551 + epinephrine. All rats were anesthetized while spontaneously breathing. Epinephrine was administered at doses of 5 μg/kg via nose, 0.25 μg/kg via femoral vein, and 0.1 μg/kg via aorta. Mean arterial pressure and heart rate were monitored. Mean arterial pressure decreased in all 3 saline + epinephrine subgroups after administration (P blood pressure reduction can be prevented by ICI 118551 in rats, suggesting that the activation of β₂-adrenoceptors contributes to blood pressure reduction.

  11. Prevalence of inter-arm blood pressure difference among clinical out-patients.

    Science.gov (United States)

    Sharma, Balkishan; Ramawat, Pramila

    2016-04-01

    An increased inter-arm blood pressure difference is an easily determined physical finding, may use as an indicator of cardio vascular event and other sever diseases. Authors evaluated 477 patients to determine the prevalence and significance of inter-arm blood pressure difference. 477 routine outdoor patients selected to observe the inter-arm blood pressure difference. Age, height, weight, body mass index, history of disease and blood pressure recorded. The prevalence of ≥10 mmHg systolic inter-arm blood pressure difference was 5.0% was more as compared to 3.8% had diastolic inter-arm blood pressure difference. The prevalence of systolic and diastolic inter-arm difference between 6 to 10 mmHg was 31.4% and 27.9% respectively. Mean systolic inter-arm blood pressure difference was significantly higher among those patients had a multisystem disorder (10.57±0.98 mmHg) and followed by patients with cardiovascular disease (10.22±0.67 mmHg) as compared to healthy patients (2.71±0.96 mmHg). Various diseases highly influenced the increase in blood pressure irrespective of systolic or diastolic was confirmed strongly significant (pdifferent inter arm blood pressure difference levels. This study supports the view of inter-arm blood pressure difference as an alarming stage of increased disease risk that incorporated to investigate potential problems at an early diagnostic stage. A significant mean difference between left and right arm blood pressure recorded for many diseases.

  12. Plantar Pressure Variation during Jogging with Different Heel Height

    Directory of Open Access Journals (Sweden)

    Y. D. Gu

    2013-01-01

    Full Text Available This paper presents the key testing and analysis results of an investigation on the effect of heel height on the plantar pressure over different foot areas in jogging. It is important in improving the understanding of jogging with high heels and damage/injury prevention. It can also potentially guide the development of suitable/adaptive exercise schemes in between daily activities with high heels. In this work, plantar pressure data were collected from 10 habituated healthy female subjects (aged 21–25 years at their natural jogging speed with three different conditions: flat heeled shoes (0.8 cm, low heeled shoes (4.0 cm, and high heeled shoes (6.6 cm. Data analysis showed significantly differences in plantar pressure distribution associated with the heel heights with increased pressure in the first metatarsal region and decreased pressure in the lateral metatarsal and midfoot sections. However, there is no significant alteration of plantar pressure in the central area of the forefoot with jogging gait.

  13. Automatic algorithm for monitoring systolic pressure variation and difference in pulse pressure.

    Science.gov (United States)

    Pestel, Gunther; Fukui, Kimiko; Hartwich, Volker; Schumacher, Peter M; Vogt, Andreas; Hiltebrand, Luzius B; Kurz, Andrea; Fujita, Yoshihisa; Inderbitzin, Daniel; Leibundgut, Daniel

    2009-06-01

    Difference in pulse pressure (dPP) reliably predicts fluid responsiveness in patients. We have developed a respiratory variation (RV) monitoring device (RV monitor), which continuously records both airway pressure and arterial blood pressure (ABP). We compared the RV monitor measurements with manual dPP measurements. ABP and airway pressure (PAW) from 24 patients were recorded. Data were fed to the RV monitor to calculate dPP and systolic pressure variation in two different ways: (a) considering both ABP and PAW (RV algorithm) and (b) ABP only (RV(slim) algorithm). Additionally, ABP and PAW were recorded intraoperatively in 10-min intervals for later calculation of dPP by manual assessment. Interobserver variability was determined. Manual dPP assessments were used for comparison with automated measurements. To estimate the importance of the PAW signal, RV(slim) measurements were compared with RV measurements. For the 24 patients, 174 measurements (6-10 per patient) were recorded. Six observers assessed dPP manually in the first 8 patients (10-min interval, 53 measurements); no interobserver variability occurred using a computer-assisted method. Bland-Altman analysis showed acceptable bias and limits of agreement of the 2 automated methods compared with the manual method (RV: -0.33% +/- 8.72% and RV(slim): -1.74% +/- 7.97%). The difference between RV measurements and RV(slim) measurements is small (bias -1.05%, limits of agreement 5.67%). Measurements of the automated device are comparable with measurements obtained by human observers, who use a computer-assisted method. The importance of the PAW signal is questionable.

  14. Pulse pressure and diabetes treatments: Blood pressure and pulse pressure difference among glucose lowering modality groups in type 2 diabetes.

    Science.gov (United States)

    Alemi, Hamid; Khaloo, Pegah; Mansournia, Mohammad Ali; Rabizadeh, Soghra; Salehi, Salome Sadat; Mirmiranpour, Hossein; Meftah, Neda; Esteghamati, Alireza; Nakhjavani, Manouchehr

    2018-02-01

    Type 2 diabetes is associated with higher pulse pressure. In this study, we assessed and compared effects of classic diabetes treatments on pulse pressure (PP), systolic blood pressure (SBP), and diastolic blood pressure (DBP) in patients with type 2 diabetes.In a retrospective cohort study, 718 non-hypertensive patients with type 2 diabetes were selected and divided into 4 groups including metformin, insulin, glibenclamide+metformin, and metformin+insulin. They were followed for 4 consecutive visits lasting about 45.5 months. Effects of drug regimens on pulse and blood pressure over time were assessed separately and compared in regression models with generalized estimating equation method and were adjusted for age, duration of diabetes, sex, smoking, and body mass index (BMI).Studied groups had no significant change in PP, SBP, and DBP over time. No significant difference in PP and DBP among studied groups was observed (PP:P = 0.090; DBP:P = 0.063). Pairwise comparisons of PP, SBP, and DBP showed no statistically significant contrast between any 2 studied groups. Interactions of time and treatment were not different among groups.Our results demonstrate patients using metformin got higher PP and SBP over time. Averagely, pulse and blood pressure among groups were not different. Trends of variation in pulse and blood pressure were not different among studied diabetes treatments.

  15. Effect of different pneumoperitoneum pressure on stress state in patients underwent gynecological laparoscopy

    Directory of Open Access Journals (Sweden)

    Ai-Yun Shen

    2016-10-01

    Full Text Available Objective: To observe the effect of different CO2 pneumoperitoneum pressure on the stress state in patients underwent gynecological laparoscopy. Methods: A total of 90 patients who were admitted in our hospital from February, 2015 to October, 2015 for gynecological laparoscopy were included in the study and divided into groups A, B, and C according to different CO2 pneumoperitoneum pressure. The changes of HR, BP, and PetCO2 during the operation process in the three groups were recorded. The changes of stress indicators before operation (T0, 30 min during operation (T1, and 12 h after operation (T2 were compared. Results: The difference of HR, BP, and PetCO2 levels before operation among the three groups was not statistically significant (P>0.05. HR, BP, and PetCO2 levels 30 min after pneumoperitoneum were significantly elevated when compared with before operation (P0.05. PetCO2 level 30 min after pneumoperitoneum in group B was significantly higher than that in group A (P0.05. Conclusions: Low pneumoperitoneum pressure has a small effect on the stress state in patients underwent gynecological laparoscopy, will not affect the surgical operation, and can obtain a preferable muscular relaxation and vision field; therefore, it can be selected in preference.

  16. Effect of different cooking methods on total phenolic contents and antioxidant activities of four Boletus mushrooms.

    Science.gov (United States)

    Sun, Liping; Bai, Xue; Zhuang, Yongliang

    2014-11-01

    The influences of cooking methods (steaming, pressure-cooking, microwaving, frying and boiling) on total phenolic contents and antioxidant activities of fruit body of Boletus mushrooms (B. aereus, B. badius, B. pinophilus and B. edulis) have been evaluated. The results showed that microwaving was better in retention of total phenolics than other cooking methods, while boiling significantly decreased the contents of total phenolics in samples under study. Effects of different cooking methods on phenolic acids profiles of Boletus mushrooms showed varieties with both the species of mushroom and the cooking method. Effects of cooking treatments on antioxidant activities of Boletus mushrooms were evaluated by in vitro assays of hydroxyl radical (OH·) -scavenging activity, reducing power and 1, 1-diphenyl-2-picrylhydrazyl radicals (DPPH·) -scavenging activity. Results indicated the changes of antioxidant activities of four Boletus mushrooms were different in five cooking methods. This study could provide some information to encourage food industry to recommend particular cooking methods.

  17. Association of Interarm Systolic Blood Pressure Difference with Atherosclerosis and Left Ventricular Hypertrophy

    Science.gov (United States)

    Su, Ho-Ming; Lin, Tsung-Hsien; Hsu, Po-Chao; Chu, Chun-Yuan; Lee, Wen-Hsien; Chen, Szu-Chia; Lee, Chee-Siong; Voon, Wen-Chol; Lai, Wen-Ter; Sheu, Sheng-Hsiung

    2012-01-01

    An interarm systolic blood pressure (SBP) difference of 10 mmHg or more have been associated with peripheral artery disease and adverse cardiovascular outcomes. We investigated whether an association exists between this difference and ankle-brachial index (ABI), brachial-ankle pulse wave velocity (baPWV), and echocardiographic parameters. A total of 1120 patients were included in the study. The bilateral arm blood pressures were measured simultaneously by an ABI-form device. The values of ABI and baPWV were also obtained from the same device. Clinical data, ABIdifference ≥10 mmHg were compared and analyzed. We performed two multivariate forward analyses for determining the factors associated with an interarm SBP difference ≥10 mmHg [model 1: significant variables in univariate analysis except left ventricular mass index (LVMI); model 2: significant variables in univariate analysis except ABIdifference ≥10 mmHg. Female, hypertension, and high body mass index were also associated with an interarm SBP difference ≥10 mmHg. Our study demonstrated that ABIdifference of 10 mmHg or more. Detection of an interarm SBP difference may provide a simple method of detecting patients at increased risk of atherosclerosis and left ventricular hypertrophy. PMID:22927905

  18. Effects of Xe Gas Content and Total Gas Pressure on the Discharge Characteristics of Colour Plasma Display Panels

    International Nuclear Information System (INIS)

    Hu Wenbo; Han Mengju; Liang Zhihu

    2006-01-01

    The effects of the Xe gas content and total gas pressure on the discharge characteristics of colour plasma display panels including the sustaining voltage margin, white-field chromaticity, discharge time lag (DTL), discharge current peak, and full-width-at-half-maximum (FWHM) of the discharge current pulse, are experimentally studied. The results indicate that as the Xe gas content in the He-Ne-Xe gas mixture or total pressure increases, the sustaining voltage margin increases, the white-field chromaticity improves, and the discharge current peak has a maximum value, while DTL and FWHM have a minimum value. The mean electron energy in the gas mixture discharge is also calculated through a numerical solution of Boltzmann equation. The experimental results are explained from a view of the mean electron energy variations with the Xe gas content and total gas pressure

  19. Mean Blood Pressure Difference among Adolescents Based on Dyssomnia Types.

    Science.gov (United States)

    Sembiring, Krisnarta; Ramayani, Oke Rina; Lubis, Munar

    2018-02-15

    Dyssomnia is the most frequent sleep disturbance and associated with increased blood pressure. There has been no study determining the difference in mean blood pressure based on dyssomnia types among adolescents. To determine the difference in mean blood pressure among adolescents based on dyssomnia types. Cross-sectional study was conducted in SMP Negeri 1 Muara Batang Gadis in April 2016. Samples were students having sleep disturbance based on Sleep Disturbance Scale for Children (SDSC) questionnaire. Stature and blood pressure data were collected along with demographic data and sleep disorder questionnaire. Analyses were done with Kruskal-Wallis test and logistic regression. P - value blood pressure (DBP) was 111.1 (SD 16.46) mmHg and 70.3 (SD 11.98) mmHg respectively. Mean SDSC score was 49.7 (SD 8.96), and the most frequent dyssomnia type was disorders of initiating and maintaining sleep. Age and sex were not the risk factors of hypertension in dyssomnia. There was a significant difference in mean SBP (P = 0.006) and DBP (P = 0.022) based on dyssomnia types. Combination dyssomnia type had the highest mean blood pressure among dyssomnia types. There is a significant difference in mean blood pressure among adolescents based on dyssomnia types.

  20. A National Trial on Differences in Cerebral Perfusion Pressure Values by Measurement Location.

    Science.gov (United States)

    McNett, Molly M; Bader, Mary Kay; Livesay, Sarah; Yeager, Susan; Moran, Cristina; Barnes, Arianna; Harrison, Kimberly R; Olson, DaiWai M

    2018-04-01

    Cerebral perfusion pressure (CPP) is a key parameter in management of brain injury with suspected impaired cerebral autoregulation. CPP is calculated by subtracting intracranial pressure (ICP) from mean arterial pressure (MAP). Despite consensus on importance of CPP monitoring, substantial variations exist on anatomical reference points used to measure arterial MAP when calculating CPP. This study aimed to identify differences in CPP values based on measurement location when using phlebostatic axis (PA) or tragus (Tg) as anatomical reference points. The secondary study aim was to determine impact of differences on patient outcomes at discharge. This was a prospective, repeated measures, multi-site national trial. Adult ICU patients with neurological injury necessitating ICP and CPP monitoring were consecutively enrolled from seven sites. Daily MAP/ICP/CPP values were gathered with the arterial transducer at the PA, followed by the Tg as anatomical reference points. A total of 136 subjects were enrolled, resulting in 324 paired observations. There were significant differences for CPP when comparing values obtained at PA and Tg reference points (p Differences remained significant in repeated measures model when controlling for clinical factors (mean CPP-PA = 80.77, mean CPP-Tg = 70.61, p identified as adequate with PA values, yet inadequate with CPP values measured at the Tg. Findings identify numerical differences for CPP based on anatomical reference location and highlight importance of a standard reference point for both clinical practice and future trials to limit practice variations and heterogeneity of findings.

  1. Pressure relieving support surfaces (PRESSURE) trial: cost effectiveness analysis.

    Science.gov (United States)

    Iglesias, Cynthia; Nixon, Jane; Cranny, Gillian; Nelson, E Andrea; Hawkins, Kim; Phillips, Angela; Torgerson, David; Mason, Su; Cullum, Nicky

    2006-06-17

    To assess the cost effectiveness of alternating pressure mattresses compared with alternating pressure overlays for the prevention of pressure ulcers in patients admitted to hospital. Cost effectiveness analysis carried out alongside the pressure relieving support surfaces (PRESSURE) trial; a multicentre UK based pragmatic randomised controlled trial. 11 hospitals in six UK NHS trusts. Intention to treat population comprising 1971 participants. Kaplan Meier estimates of restricted mean time to development of pressure ulcers and total costs for treatment in hospital. Alternating pressure mattresses were associated with lower overall costs (283.6 pounds sterling per patient on average, 95% confidence interval--377.59 pounds sterling to 976.79 pounds sterling) mainly due to reduced length of stay in hospital, and greater benefits (a delay in time to ulceration of 10.64 days on average,--24.40 to 3.09). The differences in health benefits and total costs for hospital stay between alternating pressure mattresses and alternating pressure overlays were not statistically significant; however, a cost effectiveness acceptability curve indicated that on average alternating pressure mattresses compared with alternating pressure overlays were associated with an 80% probability of being cost saving. Alternating pressure mattresses for the prevention of pressure ulcers are more likely to be cost effective and are more acceptable to patients than alternating pressure overlays.

  2. Measures of total stress-induced blood pressure responses are associated with vascular damage.

    Science.gov (United States)

    Nazzaro, Pietro; Seccia, Teresa; Vulpis, Vito; Schirosi, Gabriella; Serio, Gabriella; Battista, Loredana; Pirrelli, Anna

    2005-09-01

    The role of cardiovascular reactivity to study hypertension, and the assessment methods, are still controversial. We aimed to verify the association of hypertension and vascular damage with several measures of cardiovascular response. We studied 40 patients with normal-high (132 +/- 1/87 +/- 1 mm Hg) blood pressure (Group 1) and 80 untreated hypertensive subjects. Postischemic forearm vascular resistance (mFVR) served to differentiate hypertensive subjects (142 +/- 2/92 +/- 1 mm Hg v 143 +/- 2/94 +/- 2 mm Hg, P = NS) with a lower (Group 2) and higher (Group 3) hemodynamic index of vascular damage (4.8 +/- .05 v 6.3 +/- .09, P blood pressure, heart rate, forearm blood flow, and vascular resistance. Reactivity measures included: a) change from baseline, b) residualized score, c) cumulative change from baseline and residualized score, and d) total reactivity as area-under-the-curve (AUC), including changes occurring during baseline and recovery phases. The AUC of systolic blood pressure, diastolic blood pressure, and mFVR progressively increased in the groups (P AUC of SBP, DBP, and forearm blood flow and resistance demonstrated the highest (P AUC of SBP (beta = 0.634) and forearm blood flow (beta = -0.337) were predictive (P blood pressure stress response, as AUC, including baseline and recovery phases, was significantly better associated with hypertension and vascular damage than the other reactivity measures studied.

  3. Total gas pressure and biological response

    International Nuclear Information System (INIS)

    Powell, C.; Prince, A.

    1999-01-01

    The total gas pressure (TGP) is a possible threat to fish populations, having a potentially lethal effect on them, but if they dive below certain depths they can avoid these effects. The spatial and temporal depth distribution of adult rainbow trout in the Columbia River below the Hugh Keenleyside (HLK) Dam was monitored, and twenty one adult rainbow trout had depth sensitive electronic tags attached to them to allow their spatial and temporal depth behavior to be tracked and recorded. Nineteen of the fish were consistently relocated after release into the Columbia River, and fish were monitored during the numerous day and night 12 hour observation periods to provide a cross section of fish behavior. With a depth benchmark determined, an experiment was carried out to manipulate TGP production levels from the HLK dam and monitor the fish behavior. TGP levels were manipulated while keeping flows downstream of the dam constant. Two groups of fish were monitored and each group of fish was monitored continuously during the specific 12 hour observation periods within each experimental session. The first session recorded fish behavior when TGP was less than 110%, the second session when TGP was elevated to over 110%, and finally, when the TGP levels were lowered back below 110%. Neither temporal nor spatial fish behavior patterns of the rainbow trout monitored appeared to be influenced by the changes in TGP, compared to that of the benchmark observations. Fish continued to hold at and feed at, or within, a 5 m depth of the surface regardless of the TGP

  4. Empirical Formulas for Calculation of Negative Pressure Difference in Vacuum Pipelines

    Directory of Open Access Journals (Sweden)

    Marek Kalenik

    2015-10-01

    Full Text Available The paper presents the analysis of results of empirical investigations of a negative pressure difference in vacuum pipelines with internal diameters of 57, 81, 102 mm. The investigations were performed in an experimental installation of a vacuum sewage system, built in a laboratory hall on a scale of 1:1. The paper contains a review of the literature concerning two-phase flows (liquid-gas in horizontal, vertical and diagonal pipelines. It presents the construction and working principles of the experimental installation of vacuum sewage system in steady and unsteady conditions during a two-phase flow of water and air. It also presents a methodology for determination of formula for calculation of a negative pressure difference in vacuum pipelines. The results obtained from the measurements of the negative pressure difference Δpvr in the vacuum pipelines were analyzed and compared with the results of calculations of the negative pressure difference Δpvr, obtained from the determined formula. The values of the negative pressure difference Δpvr calculated for the vacuum pipelines with internal diameters of 57, 81, and 102 mm with the use of Formula (19 coincide with the values of Δpvr measured in the experimental installation of a vacuum sewage system. The dependence of the negative pressure difference Δpvr along the length of the vacuum pipelines on the set negative pressure in the vacuum container pvzp is linear. The smaller the vacuum pipeline diameter, the greater the negative pressure difference Δpvr is along its length.

  5. Mean Blood Pressure Difference among Adolescents Based on Dyssomnia Types

    OpenAIRE

    Krisnarta Sembiring; Oke Rina Ramayani; Munar Lubis

    2018-01-01

    BACKGROUND: Dyssomnia is the most frequent sleep disturbance and associated with increased blood pressure. There has been no study determining the difference in mean blood pressure based on dyssomnia types among adolescents. OBJECTIVE: To determine the difference in mean blood pressure among adolescents based on dyssomnia types. METHODS: a Cross-sectional study was conducted in SMP Negeri 1 Muara Batang Gadis in April 2016. Samples were students having sleep disturbance based on Sleep...

  6. Measurements of the total energy lost per electron-ion pair lost in low-pressure inductive argon, helium, oxygen and nitrogen discharge

    International Nuclear Information System (INIS)

    Lee, Young-Kwang; Ku, Ju-Hwan; Chung, Chin-Wook

    2011-01-01

    Experimental measurements of the total energy lost per electron-ion pair lost, ε T , were performed in a low-pressure inductive atomic gases (Ar, He) and molecular gases (O 2 , N 2 ) discharge. The value of ε T was determined from a power balance based on the electropositive global (volume-averaged) model. A floating harmonic method was employed to measure ion fluxes and electron temperatures at the discharge wall. In the pressure range 5-50 mTorr, it was found that the measured ε T ranged from about 70 to 150 V for atomic gases, but from about 180 to 1300 V for molecular gases. This difference between atomic and molecular discharge is caused by additional collisional energy losses of molecular gases. For argon discharge, the stepwise ionization effect on ε T was observed at relatively high pressures. For different gases, the measured ε T was evaluated with respect to the electron temperature, and then compared with the calculation results, which were derived from collisional and kinetic energy loss. The measured ε T and their calculations showed reasonable agreement.

  7. Indoor radon concentration and outdoor/indoor pressure difference correlation

    International Nuclear Information System (INIS)

    Cechak, T.; Fronka, A.; Moucka, L.

    2004-01-01

    In the current approach to the radon issue, the radon risk for people living in a building is estimated based on the average indoor radon concentration. Short-term measurements as usually applied fail to reflect the wide range of radon variations arising from ventilation, radon supply and, in particular, human activities in the building. For this reason, efforts are made to find a new approach to the assessment of the quality of a building as a radon barrier, independent of the weather conditions and residential habits. A simple model of radon volume activity entering the building at a constant rate and simultaneously ventilated at a constant rate is applicable to this task. The rate of radon ingress can be regarded as a parameter making it possible to quantify the leakage of structures provided the barrier against the radon in a soil gas. The ventilation rate, on the other hand, characterizes the leakage of the whole building envelope at a given outdoor/indoor pressure difference. A unique measuring technique called the blower door exists whereby a defined pressure difference between the indoor and outdoor atmosphere can be established. Under such conditions both the ventilation rate and the rate of radon ingress can be measured and expressed as a function of the pressure difference. An analysis of the model of a room with a constant ventilation and constant radon supply is presented and the relationship between radon supply and ventilation rate can be assumed. Some experimental results show how the model can be utilized. The real indoor-outdoor air pressure differences, the indoor-soil air pressure differences, and some effects of different ventilation regimes are given. Other experiments, which have been done by using the blower door method, illustrate the possible effects and some restrictions for a routine application are discussed

  8. Does the Position or Contact Pressure of the Stethoscope Make Any Difference to Clinical Blood Pressure Measurements

    Science.gov (United States)

    Pan, Fan; Zheng, Dingchang; He, Peiyu; Murray, Alan

    2014-01-01

    Abstract This study aimed to investigate the effect of stethoscope position and contact pressure on auscultatory blood pressure (BP) measurement. Thirty healthy subjects were studied. Two identical stethoscopes (one under the cuff, the other outside the cuff) were used to simultaneously and digitally record 2 channels of Korotkoff sounds during linear cuff pressure deflation. For each subject, 3 measurements with different contact pressures (0, 50, and 100 mm Hg) on the stethoscope outside the cuff were each recorded at 3 repeat sessions. The Korotkoff sounds were replayed twice on separate days to each of 2 experienced listeners to determine systolic and diastolic BPs (SBP and DBP). Variance analysis was performed to study the measurement repeatability and the effect of stethoscope position and contact pressure on BPs. There was no significant BP difference between the 3 repeat sessions, between the 2 determinations from each listener, between the 2 listeners and between the 3 stethoscope contact pressures (all P > 0.06). There was no significant SBP difference between the 2 stethoscope positions at the 2 lower stethoscope pressures (P = 0.23 and 0.45), but there was a small (0.4 mm Hg, clinically unimportant) significant difference (P = 0.005) at the highest stethoscope pressure. The key result was that, DBP from the stethoscope under the cuff was significantly lower than that from outside the cuff by 2.8 mm Hg (P stethoscope outside the cuff, tends to give a higher DBP than the true intra-arterial pressure, this study could suggest that the stethoscope position under the cuff, and closer to the arterial occlusion, might yield measurements closer to the actual invasive DBP. PMID:25546675

  9. Simulation of a scenario of total loss of external and internal power (Sbo) for different vent pressures of the containment of a BWR-5

    International Nuclear Information System (INIS)

    Cardenas V, J.; Mugica R, C. A.; Godinez S, V.

    2014-10-01

    The simulation of a Station Black Out (Sbo) was realized with intervention of the vent containment by means of a rigid vent coming from the dry-well and that discharges directly to the atmosphere, with the MELCOR code version 2.1. This scenario was carried out for a BWR-5 and containment type Mark II, with a thermal power of 2317 MWt similar to the reactor of nuclear power plant of Laguna Verde. For this scenario was considered as only available system for coolant injection to the reactor to the Reactor Core Isolation Cooling (Rcic), which remained operating 4 hours with batteries bank. The Security and Relief Valves (SR V) were considered functional (by simplicity) and that they mechanically do not exceed their capacity to liberate pressure due to the performances in their safety way. The operator maneuver to perform the SR V and to de pressurize the vessel until the pressure (13 kg/cm 2 ) to operate the low pressure systems was modeled. The results cover approximately 48 hours (172000 seconds), time in which was observed the behavior of the level and pressure in the vessel. Also the scenario evolution was analyzed to different vent pressures of the primary containment (2.0, 3.0, 4.5, 6.0, and 10.0 kg/cm 2 ), the temperature profiles of the dry-well, the hydrogen accumulation in the containment, the radio-nuclides liberation through rigid vent to the atmosphere and the inventory of these. In this work an analysis of the pressure behavior in the primary containment is presented, with the purpose of minimizing liberated fission products to the environment. (Author)

  10. Lower limb intracast pressures generated by different types of immobilisation casts.

    Science.gov (United States)

    Chaudhury, Salma; Hazlerigg, Alexandra; Vusirikala, Anuhya; Nguyen, Joseph; Matthews, Stuart

    2017-02-18

    To determine if complete, split casts and backslabs [plaster of Paris (POP) and fiberglass] generate different intracast pressures and pain. Increased swelling within casts was modeled by a closed water system attached to an expandable bag placed directly under different types of casts applied to a healthy lower limb. Complete fiberglass and POP casts, split casts and backslabs were applied. Twenty-five milliliter aliquots of saline were injected into the system and the generated intracast pressures were measured using a sphygmomanometer. The subject was blinded to the pressure scores to avoid bias. All casts were applied to the same right limb on the same subject to avoid the effects of variations in anatomy or physiology on intracast pressures. Pain levels were evaluated using the Visual Analogue Score after each sequential saline injection. Each type of cast was reapplied four times and the measurements were repeated on four separate occasions. Sample sizes were determined by a pre-study 90% power calculation to detect a 20% difference in intracast pressures between cast groups. A significant difference between the various types of casts was noted when the saline volume was greater than 100 mL ( P = 0.009). The greatest intracast pressure was generated by complete fiberglass casts, which were significantly higher than complete POP casts or backslabs ( P = 0.018 and P = 0.008 respectively) at intracast saline volumes of 100 mL and higher. Backslabs produced a significantly lower intracast pressure compared to complete POP only once the saline volume within casts exceeded 225 mL ( P = 0.009). Intracast pressures were significantly lower in split casts ( P = 0.003). Split POP and fiberglass casts produced the lowest intracast pressures, even compared to backslabs ( P = 0.009). Complete fiberglass casts generated the highest pain levels at manometer pressures of 75 mmHg and greater ( P = 0.001). Split fiberglass casts had significantly reduced pain levels ( P = 0

  11. Clinical significance of inter-arm pressure difference and ankle-brachial pressure index in patients with suspected coronary artery disease

    International Nuclear Information System (INIS)

    Igarashi, Yuko; Chikamori, Taishiro; Tomiyama, Hirofumi; Usui, Yasuhiro; Hida, Satoshi; Tanaka, Hirokazu; Nagao, Tadashi; Yamashina, Akira

    2007-01-01

    Although measuring blood pressure at the bilateral brachia is common in medical practice, its clinical significance in patients with suspected coronary artery disease (CAD) has not been fully clarified. The method of this study was to define the significance of inter-arm systolic blood pressure difference in patients with suspected CAD, and to assess the relationship between inter-arm pressure difference and CAD, simultaneous brachial and ankle blood pressure measurements and stress myocardial single-photon emission computed tomography (SPECT) were performed in 386 consecutive patients with suspected CAD, excluding those with previous myocardial infarction or coronary revascularization. Subclavian artery stenosis, defined as ≥15 mmHg inter-arm systolic blood pressure difference, was found in 27 patients (7%). Age (65±12 vs 65±11 years), male sex (21/27 vs 244/359), prevalence of hypertension (63% vs 56%), hypercholesterolemia (63% vs 62%), diabetes mellitus (33% vs 38%), cigarette smoking (44% vs 41%) and family history of CAD (15% vs 12%) were similar between patients with subclavian artery stenosis and those without. The incidence of decreased ankle-brachial pressure index (ABI) was higher (37% vs 12%, p=0.001), and percentage ischemic myocardium as assessed by SPECT was greater (9.0±8.5% vs 5.6±6.6%, p=0.05) in patients with subclavian artery stenosis than in those without. Furthermore, significant correlations were observed between inter-arm pressure difference and percentage ischemic myocardium (r=0.13; p=0.01), and ABI (r=-0.26, p<0.0001). Among 386 patients, 283 underwent coronary angiography, and 63% of those who had inter-arm blood pressure difference had CAD. Furthermore, 83% of those CAD patients had multi-vessel CAD, which is regarded as a high-risk subset for subsequent cardiac events. Inter-arm pressure difference is often found in patients with suspected CAD, and is associated with significant CAD and peripheral artery disease. Thus, inter

  12. Evaluation of the impact of atmospheric pressure in different seasons on blood pressure in patients with arterial hypertension.

    Science.gov (United States)

    Kamiński, Marek; Cieślik-Guerra, Urszula I; Kotas, Rafał; Mazur, Piotr; Marańda, Witold; Piotrowicz, Maciej; Sakowicz, Bartosz; Napieralski, Andrzej; Trzos, Ewa; Uznańska-Loch, Barbara; Rechciński, Tomasz; Kurpesa, Małgorzata

    2016-01-01

    Atmospheric pressure is the most objective weather factor because regardless of if outdoors or indoors it affects all objects in the same way. The majority of previous studies have used the average daily values of atmospheric pressure in a bioclimatic analysis and have found no correlation with blood pressure changes. The main objective of our research was to assess the relationship between atmospheric pressure recorded with a frequency of 1 measurement per minute and the results of 24-h blood pressure monitoring in patients with treated hypertension in different seasons in the moderate climate of the City of Łódź (Poland). The study group consisted of 1662 patients, divided into 2 equal groups (due to a lower and higher average value of atmospheric pressure). Comparisons between blood pressure values in the 2 groups were performed using the Mann-Whitney U test. We observed a significant difference in blood pressure recorded during the lower and higher range of atmospheric pressure: on the days of the spring months systolic (p = 0.043) and diastolic (p = 0.005) blood pressure, and at nights of the winter months systolic blood pressure (p = 0.013). A significant inverse relationship between atmospheric pressure and blood pressure during the spring days and, only for systolic blood pressure, during winter nights was observed. Int J Occup Med Environ Health 2016;29(5):783-792. This work is available in Open Access model and licensed under a CC BY-NC 3.0 PL license.

  13. Sensitivity of total stress to changes in externally applied water pressure in KBS-3 buffer bentonite

    Energy Technology Data Exchange (ETDEWEB)

    Harrington, J.F.; Birchall, D.J. [British Geological Survey, Chemical and Biological Hazards Programme, Kingsley Dunham Centre (United Kingdom)

    2007-04-15

    In the current Swedish repository design concept, composite copper and steel canisters containing spent nuclear fuel will be placed in large diameter disposal boreholes drilled into the floor of the repository tunnels. The space around each canister will be filled with pre-compacted bentonite which over time will draw in the surrounding ground water and swell, closing up any construction joints. However, for the purposes of performance assessment, it is necessary to consider the effect of glacial loading of a future repository and its impact on the mechanical behaviour of the bentonite, in particular, the sensitivity of total stress to changes in porewater pressure (backpressure). Two experimental histories have been undertaken using a custom-designed constant volume and radial flow (CVRF) apparatus. In both tests backpressure was varied in a number of incremental and decremental cycles while total stress, porewater pressure and volumetric flow rate were continuously monitored. The swelling pressure of the buffer clay at dry densities of 1.8 Mg/m{sup 3} and 1.61 Mg/m{sup 3} was determined to be around 5.5 MPa and 7.2 MPa respectively. For initial ascending porewater pressure histories the average proportionality factor {alpha} ranged from 0.86 and 0.92. Data exhibited a general trend of increasing {alpha} with increasing backpressure. In test Mx80-11 this was supported by analysis of the water inflow data which indicated a reduction in system compressibility. Asymptotic values of porewater pressure within the clay are in good agreement with externally applied backpressure values. Inspection of data provides no evidence for the development of hydraulic thresholds within the clay, subject to the boundary conditions of this test geometry. Analysis of the stress data demonstrates significant hysteresis between ascending and descending porewater pressure histories. The amount of hysteresis appears to be linked to the magnitude of the backpressure applied to the specimen

  14. Sensitivity of total stress to changes in externally applied water pressure in KBS-3 buffer bentonite

    International Nuclear Information System (INIS)

    Harrington, J.F.; Birchall, D.J.

    2007-04-01

    In the current Swedish repository design concept, composite copper and steel canisters containing spent nuclear fuel will be placed in large diameter disposal boreholes drilled into the floor of the repository tunnels. The space around each canister will be filled with pre-compacted bentonite which over time will draw in the surrounding ground water and swell, closing up any construction joints. However, for the purposes of performance assessment, it is necessary to consider the effect of glacial loading of a future repository and its impact on the mechanical behaviour of the bentonite, in particular, the sensitivity of total stress to changes in porewater pressure (backpressure). Two experimental histories have been undertaken using a custom-designed constant volume and radial flow (CVRF) apparatus. In both tests backpressure was varied in a number of incremental and decremental cycles while total stress, porewater pressure and volumetric flow rate were continuously monitored. The swelling pressure of the buffer clay at dry densities of 1.8 Mg/m 3 and 1.61 Mg/m 3 was determined to be around 5.5 MPa and 7.2 MPa respectively. For initial ascending porewater pressure histories the average proportionality factor α ranged from 0.86 and 0.92. Data exhibited a general trend of increasing α with increasing backpressure. In test Mx80-11 this was supported by analysis of the water inflow data which indicated a reduction in system compressibility. Asymptotic values of porewater pressure within the clay are in good agreement with externally applied backpressure values. Inspection of data provides no evidence for the development of hydraulic thresholds within the clay, subject to the boundary conditions of this test geometry. Analysis of the stress data demonstrates significant hysteresis between ascending and descending porewater pressure histories. The amount of hysteresis appears to be linked to the magnitude of the backpressure applied to the specimen, suggesting some

  15. Acute tamponade alters subendo- and subepicardial pressure-flow relations differently during vasodilation.

    Science.gov (United States)

    Kingma, J G; Martin, J; Rouleau, J R

    1994-07-01

    Instantaneous diastolic left coronary artery pressure-flow relations (PFR) shift during acute tamponade as pressure surrounding the heart increases. Coronary pressure at zero flow (Pf = 0) on the linear portion of the PFR is the weighted mean of the different myocardial waterfall pressures, the distribution of which varies across the left ventricular wall during diastole. However, instantaneous PFR measured in large epicardial coronary arteries cannot be used to estimate Pf = 0 in the different myocardial tissue layers. During coronary vasodilatation in a capacitance-free model, myocardial PFR differs from subendocardium to subepicardium. Therefore, we studied the effects of acute tamponade during maximal pharmacology induced coronary vasodilatation on myocardial PFR in in situ anesthetized dogs. Tamponade reduced cardiac output, aortic pressure, and coronary blood flow. Results demonstrate that different mechanisms influence distribution of myocardial blood flow during tamponade. Subepicardial vascular resistance is unchanged and the extrapolated Pf = 0 is increased, thereby shifting PFR to a higher intercept on the pressure axis. Subendocardial vascular resistance is increased while the extrapolated Pf = 0 remains unchanged. Results indicate that in the setting of acute tamponade with coronary vasodilatation different mechanisms regulate the distribution of myocardial blood flow: in the subepicardium only outflow pressure increases, whereas in the subendocardium only vascular resistance increases.

  16. Numerical Studies on the Effects of the Channel-Inlet-Pressure Difference in the Pressure-Retarded Osmosis (PRO) Power System

    International Nuclear Information System (INIS)

    Hong, Sung Soo; Ryoo, Won; Chung, Gui Yung; Chun, Myung-Suk

    2014-01-01

    In the spiral wound module of the pressure-retarded osmosis (PRO) system for the salinity gradient power generation, effects of the inlet pressure differences between feed-channel and draw-channel were studied. Fluxes of water and solute through membrane and power were estimated. The water flux through membrane decreased along the x-direction and increased along the y-direction with the increase of inlet pressure differences between two channels. On the other hand, the solute flux through membrane showed the opposite trend. The concentration of flow in the feed-channel increased a lot along the y-direction and that in the draw-channel decreased along the x-direction. In our system, for the inlet pressure differences of 1-11 atm, the flow rate in the feed-channel decreased about 8-13% and that in the draw-channel increased by the same amount. The power density increased and then decreased with the increasing inlet pressure difference

  17. Numerical Studies on the Effects of the Channel-Inlet-Pressure Difference in the Pressure-Retarded Osmosis (PRO) Power System

    Energy Technology Data Exchange (ETDEWEB)

    Hong, Sung Soo; Ryoo, Won; Chung, Gui Yung [Hong-Ik University, Seoul (Korea, Republic of); Chun, Myung-Suk [Korea Institute of Science and Technology (KIST), Seoul (Korea, Republic of)

    2014-02-15

    In the spiral wound module of the pressure-retarded osmosis (PRO) system for the salinity gradient power generation, effects of the inlet pressure differences between feed-channel and draw-channel were studied. Fluxes of water and solute through membrane and power were estimated. The water flux through membrane decreased along the x-direction and increased along the y-direction with the increase of inlet pressure differences between two channels. On the other hand, the solute flux through membrane showed the opposite trend. The concentration of flow in the feed-channel increased a lot along the y-direction and that in the draw-channel decreased along the x-direction. In our system, for the inlet pressure differences of 1-11 atm, the flow rate in the feed-channel decreased about 8-13% and that in the draw-channel increased by the same amount. The power density increased and then decreased with the increasing inlet pressure difference.

  18. Effects of salt substitute on home blood pressure differs according to age and degree of blood pressure in hypertensive patients and their families.

    Science.gov (United States)

    Hu, Jihong; Zhao, Liancheng; Thompson, Brian; Zhang, Yawei; Wu, Yangfeng

    2018-02-05

    It is known that home blood pressure (HBP) is a more reliable assessment of hypertension treatments than clinical blood pressure (BP). Despite this, HBP response to a salt substitute has only been evaluated by one study which, did not look at the salt substitute's effect on family members and did not analyze by age, gender, or BP degree. The aim of this current study was to assess the effects of a low-sodium and high-potassium salt substitute on HBP among hypertensive patients and their family members. A total of 220 households (including 220 hypertensive patients and 380 their families) were randomly assigned to the regular salt or salt substitute groups. HBP was measured at the beginning, 3rd, 6th, and 12th months. Among the patients (n = 220), only home systolic blood pressure (HSBP) was significantly reduced, by an adjusted baseline BP of 4.2 mm Hg (95% CI: 1.3-7.0 mm Hg), in the salt substitute group compared with those in the regular salt group at each visit (all P blood pressure (HDBP) at any visit. Among the family members, HSBP and HDBP were not significantly different between the groups. Furthermore, Individuals ≥60 years old, hypertensive patients with stage-2 hypertension, family members with hypertension, and women experienced greater HSBP reduction. Older subjects, those with higher blood pressure, and women experienced greater home blood pressure reduction from the salt substitute compared to regular salt.

  19. Simultaneously Measured Interarm Blood Pressure Difference and Stroke: An Individual Participants Data Meta-Analysis.

    Science.gov (United States)

    Tomiyama, Hirofumi; Ohkuma, Toshiaki; Ninomiya, Toshiharu; Mastumoto, Chisa; Kario, Kazuomi; Hoshide, Satoshi; Kita, Yoshikuni; Inoguchi, Toyoshi; Maeda, Yasutaka; Kohara, Katsuhiko; Tabara, Yasuharu; Nakamura, Motoyuki; Ohkubo, Takayoshi; Watada, Hirotaka; Munakata, Masanori; Ohishi, Mitsuru; Ito, Norihisa; Nakamura, Michinari; Shoji, Tetsuo; Vlachopoulos, Charalambos; Yamashina, Akira

    2018-06-01

    We conducted individual participant data meta-analysis to examine the validity of interarm blood pressure difference in simultaneous measurement as a marker to identify subjects with ankle-brachial pressure index blood pressure difference >5 mm Hg as being associated with a significant odds ratio for the presence of ankle-brachial pressure index blood pressure difference >15 mm Hg was associated with a significant Cox stratified adjusted hazard ratio for subsequent stroke (hazard ratio, 2.42; 95% confidence interval, 1.27-4.60; P blood pressure differences, measured simultaneously in both arms, may be associated with vascular damage in the systemic arterial tree. These differences may be useful for identifying subjects with an ankle-brachial pressure index of blood pressure in both arms at the first visit. © 2018 American Heart Association, Inc.

  20. Blood volume, blood pressure and total body sodium: internal signalling and output control

    DEFF Research Database (Denmark)

    Bie, P

    2009-01-01

    Total body sodium and arterial blood pressure (ABP) are mutually dependent variables regulated by complex control systems. This review addresses the role of ABP in the normal control of sodium excretion (NaEx), and the physiological control of renin secretion. NaEx is a pivotal determinant of ABP......, and under experimental conditions, ABP is a powerful, independent controller of NaEx. Blood volume is a function of dietary salt intake; however, ABP is not, at least not in steady states. A transient increase in ABP after a step-up in sodium intake could provide a causal relationship between ABP...... and the regulation of NaEx via a hypothetical integrative control system. However, recent data show that subtle sodium loading (simulating salty meals) causes robust natriuresis without changes in ABP. Changes in ABP are not necessary for natriuresis. Normal sodium excretion is not regulated by pressure. Plasma...

  1. Gender differences in blood pressure regulation following artificial gravity exposure

    Science.gov (United States)

    Evans, Joyce; Goswami, Nandu; Kostas, Vladimir; Zhang, Qingguang; Ferguson, Connor; Moore, Fritz; Stenger, Michael, , Dr; Serrador, Jorge; W, Siqi

    Introduction. Before countermeasures to space flight cardiovascular deconditioning are established, gender differences in cardiovascular responses to orthostatic stress, in general, and to orthostatic stress following exposure to artificial gravity (AG), in particular, need to be determined. Our recent determination that a short exposure to AG improved the orthostatic tolerance limit (OTL) of cardiovascularly deconditioned subjects drives the current effort to determine mechanisms of that improvement in men and in women. Methods. We determined the OTL of 9 men and 8 women following a 90 min exposure to AG compared to that following 90 min of head down bed rest (HDBR). On both days (21 days apart), subjects were made hypovolemic (low salt diet plus 20 mg intravenous furosemide) and orthostatic tolerance was determined from a combination of head up tilt and increasing lower body negative pressure until presyncope. Mean values and correlations with OTL were determined for heart rate, blood pressure, stroke volume, cardiac output, total peripheral resistance (Finometer), middle cerebral artery flow velocity (DWL), partial pressure of carbon dioxide (Novametrics) and body segmental impedance (UFI THRIM) at supine baseline, during orthostatic stress to presyncope and at supine recovery. Results. Orthostatic tolerance of these hypovolemic subjects was significantly greater following AG than following HDBR. Exposure to AG increased cardiac output in both men and women and increased stroke volume in women. In addition, AG decreased systolic blood pressure in men, but not women, and increased cerebral flow in women, but not men. In both men and women, AG exposure decreased peripheral resistance and decreased cerebrovascular resistance in women. Men’s heart rate rose more at the end of OTL on their AG, compared to their HDBR, day but women’s fell. Presyncopal stroke volume reached the same level on each day of study for both men and women. Conclusions. In the present

  2. Effect of total pressure on sulfur capture of Ca-ion exchanged coal; Kaatsu jokenka ni okeru Ca-tanjitan no datsuryu koka

    Energy Technology Data Exchange (ETDEWEB)

    Lin, S.; Benjamin, G.; Abe, H.; Harano, A.; Takarada, T. [Gunma University, Gunma (Japan). Faculty of Engineering

    1996-10-28

    In relation to coal gasification and combustion under high pressure as highly efficient coal utilization, the effect of total pressure and sintering on the SO2 capture ability of Ca-ion exchanged coal and other desulfurizing agents were studied. In experiment, specimens were filled into a small pressurized reactor to heat them under high-pressure N2 atmosphere. After the completion of combustion reaction of char at 850{degree}C, SO2, CO2 and CO gases were measured at an outlet while flowing SO2/N2. As the experimental result, all of the S content in Ca-ion exchanged coal was not absorbed by Ca content in coal during pyrolysis and combustion, resulting in discharge of 36% of the S content. Since Ca-ion exchanged coal is fast in combustion reaction, most of the S content was desulfurized by coal ash. The ash content yielded from Ca-ion exchanged coal was more excellent in SO2 capture ability than limestone even under higher pressure. In the case of CO2 partial pressure lower than equilibrium CO2 pressure for CaCO3 decomposition, the capture ability decreased with an increase in total pressure, while in higher CO2 partial pressure, it was improved. 1 ref., 7 figs., 2 tabs.

  3. Difference in blood pressure measurements between arms: methodological and clinical implications.

    Science.gov (United States)

    Clark, Christopher E

    2015-01-01

    Differences in blood pressure measurements between arms are commonly encountered in clinical practice. If such differences are not excluded they can delay the diagnosis of hypertension and can lead to poorer control of blood pressure levels. Differences in blood pressure measurements between arms are associated cross sectionally with other signs of vascular disease such as peripheral arterial disease or cerebrovascular disease. Differences are also associated prospectively with increased cardiovascular mortality and morbidity and all cause mortality. Numbers of publications on inter-arm difference are rising year on year, indicating a growing interest in the phenomenon. The prevalence of an inter-arm difference varies widely between reports, and is correlated with the underlying cardiovascular risk of the population studied. Prevalence is also sensitive to the method of measurement used. This review discusses the prevalence of an inter-arm difference in different populations and addresses current best practice for the detection and the measurement of a difference. The evidence for clinical and for vascular associations of an inter-arm difference is presented in considering the emerging role of an inter-arm blood pressure difference as a novel risk factor for increased cardiovascular morbidity and mortality. Competing aetiological explanations for an inter-arm difference are explored, and gaps in our current understanding of this sign, along with areas in need of further research, are considered.

  4. Effect of high-pressure homogenization on different matrices of food supplements.

    Science.gov (United States)

    Martínez-Sánchez, Ascensión; Tarazona-Díaz, Martha Patricia; García-González, Antonio; Gómez, Perla A; Aguayo, Encarna

    2016-12-01

    There is a growing demand for food supplements containing high amounts of vitamins, phenolic compounds and mineral content that provide health benefits. Those functional compounds have different solubility properties, and the maintenance of their compounds and the guarantee of their homogenic properties need the application of novel technologies. The quality of different drinkable functional foods after thermal processing (0.1 MPa) or high-pressure homogenization under two different conditions (80 MPa, 33 ℃ and 120 MPa, 43 ℃) was studied. Physicochemical characteristics and sensory qualities were evaluated throughout the six months of accelerated storage at 40 ℃ and 75% relative humidity (RH). Aroma and color were better maintained in high-pressure homogenization-treated samples than the thermally treated ones, which contributed significantly to extending their shelf life. The small particle size obtained after high-pressure homogenization treatments caused differences in turbidity and viscosity with respect to heat-treated samples. The use of high-pressure homogenization, more specifically, 120 MPa, provided active ingredient homogeneity to ensure uniform content in functional food supplements. Although the effect of high-pressure homogenization can be affected by the food matrix, high-pressure homogenization can be implemented as an alternative to conventional heat treatments in a commercial setting within the functional food supplement or pharmaceutical industry. © The Author(s) 2016.

  5. Determinants of day-night difference in blood pressure, a comparison with determinants of daytime and night-time blood pressure.

    Science.gov (United States)

    Musameh, M D; Nelson, C P; Gracey, J; Tobin, M; Tomaszewski, M; Samani, N J

    2017-01-01

    Blunted day-night difference in blood pressure (BP) is an independent cardiovascular risk factor, although there is limited information on determinants of diurnal variation in BP. We investigated determinants of day-night difference in systolic (SBP) and diastolic (DBP) BP and how these compared with determinants of daytime and night-time SBP and DBP. We analysed the association of mean daytime, mean night-time and mean day-night difference (defined as (mean daytime-mean night-time)/mean daytime) in SBP and DBP with clinical, lifestyle and biochemical parameters from 1562 adult individuals (mean age 38.6) from 509 nuclear families recruited in the GRAPHIC Study. We estimated the heritability of the various BP phenotypes. In multivariate analysis, there were significant associations of age, sex, markers of adiposity (body mass index and waist-hip ratio), plasma lipids (total and low-density lipoprotein cholesterol and triglycerides), serum uric acid, alcohol intake and current smoking status on daytime or night-time SBP and/or DBP. Of these, only age (P=4.7 × 10 -5 ), total cholesterol (P=0.002), plasma triglycerides (P=0.006) and current smoking (P=3.8 × 10 -9 ) associated with day-night difference in SBP, and age (P=0.001), plasma triglyceride (P=2.2 × 10 -5 ) and current smoking (3.8 × 10 -4 ) associated with day-night difference in DBP. 24-h, daytime and night-time SBP and DBP showed substantial heritability (ranging from 18-43%). In contrast day-night difference in SBP showed a lower heritability (13%) while heritability of day-night difference in DBP was not significant. These data suggest that specific clinical, lifestyle and biochemical factors contribute to inter-individual variation in daytime, night-time and day-night differences in SBP and DBP. Variation in day-night differences in BP is largely non-genetic.

  6. Determinants of day–night difference in blood pressure, a comparison with determinants of daytime and night-time blood pressure

    Science.gov (United States)

    Musameh, M D; Nelson, C P; Gracey, J; Tobin, M; Tomaszewski, M; Samani, N J

    2017-01-01

    Blunted day–night difference in blood pressure (BP) is an independent cardiovascular risk factor, although there is limited information on determinants of diurnal variation in BP. We investigated determinants of day–night difference in systolic (SBP) and diastolic (DBP) BP and how these compared with determinants of daytime and night-time SBP and DBP. We analysed the association of mean daytime, mean night-time and mean day–night difference (defined as (mean daytime−mean night-time)/mean daytime) in SBP and DBP with clinical, lifestyle and biochemical parameters from 1562 adult individuals (mean age 38.6) from 509 nuclear families recruited in the GRAPHIC Study. We estimated the heritability of the various BP phenotypes. In multivariate analysis, there were significant associations of age, sex, markers of adiposity (body mass index and waist–hip ratio), plasma lipids (total and low-density lipoprotein cholesterol and triglycerides), serum uric acid, alcohol intake and current smoking status on daytime or night-time SBP and/or DBP. Of these, only age (P=4.7 × 10−5), total cholesterol (P=0.002), plasma triglycerides (P=0.006) and current smoking (P=3.8 × 10−9) associated with day–night difference in SBP, and age (P=0.001), plasma triglyceride (P=2.2 × 10−5) and current smoking (3.8 × 10−4) associated with day–night difference in DBP. 24-h, daytime and night-time SBP and DBP showed substantial heritability (ranging from 18–43%). In contrast day–night difference in SBP showed a lower heritability (13%) while heritability of day–night difference in DBP was not significant. These data suggest that specific clinical, lifestyle and biochemical factors contribute to inter-individual variation in daytime, night-time and day–night differences in SBP and DBP. Variation in day–night differences in BP is largely non-genetic. PMID:26984683

  7. Detection limit calculations for different total reflection techniques

    International Nuclear Information System (INIS)

    Sanchez, H.J.

    2000-01-01

    In this work, theoretical calculations of detection limits for different total-reflection techniques are presented.. Calculations include grazing incidence (TXRF) and gracing exit (GEXRF) conditions. These calculations are compared with detection limits obtained for conventional x-ray fluorescence (XRF). In order to compute detection limits the Shiraiwa and Fujino's model to calculate x-ray fluorescence intensities was used. This model made certain assumptions and approximations to achieve the calculations, specially in the case of the geometrical conditions of the sample, and the incident and takeoff beams. Nevertheless the calculated data of detection limits for conventional XRF and total-reflection XRF show a good agreement with previous results. The model proposed here allows to analyze the different sources of background and the influence of the excitation geometry, which contribute to the understanding of the physical processes involved in the XRF analysis by total reflection. Finally, a comparison between detection limits in total-reflection analysis at grazing incidence and at grazing exit is carried out. Here a good agreement with the theoretical predictions of the reversibility principle is found, showing that detection limits are similar for both techniques. (author)

  8. Generational Differences in Resistance to Peer Pressure among Mexican-Origin Adolescents.

    Science.gov (United States)

    Umana-Taylor, Adriana J.; Bamaca-Gomez, Mayra Y.

    2003-01-01

    Examined whether Mexican origin adolescents who varied by generational status would differ in their resistance to peer pressure. After controlling for gender, resistance to peer pressure varied significantly by generational status. Adolescents with no familial births in the United States were significantly more resistant to peer pressure than…

  9. Interarm blood pressure difference in a post-stroke population.

    Science.gov (United States)

    Gaynor, Eva; Brewer, Linda; Mellon, Lisa; Hall, Patricia; Horgan, Frances; Shelley, Emer; Dolan, Eamonn; Hickey, Anne; Bennett, Kathleen; Williams, David J

    2017-09-01

    An increased interarm systolic blood pressure (SBP) difference of ≥10 mm Hg is associated with increased cardiovascular risk and a difference of ≥15 mm Hg with increased cerebrovascular risk. The stroke population presents a high-risk group for future cardiovascular and cerebrovascular events and therefore estimation of interarm SBP difference as a predictive tool may assist with further secondary stroke prevention. The aim of the study was to determine the prevalence of interarm SBP and diastolic blood pressure difference in a post-stroke population. A comprehensive assessment of secondary risk factors along with blood pressure measurements were taken 6-months' post-ischemic stroke from the Action on Secondary Prevention Interventions and Rehabilitation in Stroke cohort. Descriptive and logistic regression analyses were performed. Odds ratios and 95% confidence intervals are presented. Two hundred thirty-eight (M: F,139:99; mean age, 68.4 years) of 256 patients followed up at 6 months post-stroke had suitable blood pressure readings from both arms. Ninety-six patients (40.3%) had an interarm SBP difference of ≥10 mm Hg and 49 (20.6%) had a difference of ≥15 mm Hg. A history of hypertension, diabetes, smoking, and obesity was not significantly associated with an increased risk of interarm SBP difference. After multivariate logistic analysis, a history of alcohol excess was associated with an increased IASBP ≥15 mm Hg (odds ratio 2.32, 95% confidence interval 1.03-5.22). We have demonstrated that interarm SBP difference is commonly seen in a post stroke population. Copyright © 2017 American Society of Hypertension. Published by Elsevier Inc. All rights reserved.

  10. Office blood pressure or ambulatory blood pressure for the prediction of cardiovascular events

    DEFF Research Database (Denmark)

    Mortensen, Rikke Nørmark; Gerds, Thomas Alexander; Jeppesen, Jørgen Lykke

    2017-01-01

    Aims: To determine the added value of (i) 24-h ambulatory blood pressure relative to office blood pressure and (ii) night-time ambulatory blood pressure relative to daytime ambulatory blood pressure for 10-year person-specific absolute risks of fatal and non-fatal cardiovascular events. Methods...... and results: A total of 7927 participants were included from the International Database on Ambulatory blood pressure monitoring in relation to Cardiovascular Outcomes. We used cause-specific Cox regression to predict 10-year person-specific absolute risks of fatal and non-fatal cardiovascular events....... Discrimination of 10-year outcomes was assessed by time-dependent area under the receiver operating characteristic curve (AUC). No differences in predicted risks were observed when comparing office blood pressure and ambulatory blood pressure. The median difference in 10-year risks (1st; 3rd quartile) was -0...

  11. Evaluation of spatial pressure distribution during ice-structure interaction using pressure indicating film

    Directory of Open Access Journals (Sweden)

    Kim Hyunwook

    2014-09-01

    Full Text Available Understanding of ‘spatial’ pressure distribution is required to determine design loads on local structures, such as plating and framing. However, obtaining a practical ‘spatial’ pressure distribution is a hard task due to the sensitivity of the data acquisition frequency and resolution. High-resolution Pessure-Idicating Flm (PIF was applied to obtain pressure distribution and pressure magnitude using stepped crushing method. Different types of PIF were stacked at each test to creating a pressure distribution plot at specific time steps. Two different concepts of plotting ‘spatial’ pressure-area curve was introduced and evaluated. Diverse unit pixel size was chosen to investigate the effect of the resolution in data analysis. Activated area was not significantly affected by unit pixel size; however, total force was highly sensitive

  12. An ex vivo porcine skin model to evaluate pressure-reducing devices of different mechanical properties used for pressure ulcer prevention.

    Science.gov (United States)

    Yeung, Ching-Yan C; Holmes, David F; Thomason, Helen A; Stephenson, Christian; Derby, Brian; Hardman, Matthew J

    2016-11-01

    Pressure ulcers are complex wounds caused by pressure- and shear-induced trauma to skin and underlying tissues. Pressure-reducing devices, such as dressings, have been shown to successfully reduce pressure ulcer incidence, when used in adjunct to pressure ulcer preventative care. While pressure-reducing devices are available in a range of materials, with differing mechanical properties, understanding of how a material's mechanical properties will influence clinical efficacy remains limited. The aim of this study was to establish a standardized ex vivo model to allow comparison of the cell protection potential of two gel-like pressure-reducing devices with differing mechanical properties (elastic moduli of 77 vs. 35 kPa). The devices also displayed differing energy dissipation under compressive loading, and resisted strain differently under constant load in compressive creep tests. To evaluate biological efficacy we employed a new ex vivo porcine skin model, with a confirmed elastic moduli closely matching that of human skin (113 vs. 119 kPa, respectively). Static loads up to 20 kPa were applied to porcine skin ex vivo with subsequent evaluation of pressure-induced cell death and cytokine release. Pressure application alone increased the percentage of epidermal apoptotic cells from less than 2% to over 40%, and increased cellular secretion of the pro-inflammatory cytokine TNF-alpha. Co-application of a pressure-reducing device significantly reduced both cellular apoptosis and cytokine production, protecting against cellular damage. These data reveal new insight into the relationship between mechanical properties of pressure-reducing devices and their biological effects. After appropriate validation of these results in clinical pressure ulcer prevention with all tissue layers present between the bony prominence and external surface, this ex vivo porcine skin model could be widely employed to optimize design and evaluation of devices aimed at reducing pressure

  13. Hydraulic High Pressure Valve Controller Using the In-Situ Pressure Difference

    Science.gov (United States)

    Bao, Xiaoqi (Inventor); Sherrit, Stewart (Inventor); Badescu, Mircea (Inventor); Bar-Cohen, Yoseph (Inventor); Hall, Jeffery L. (Inventor)

    2016-01-01

    A hydraulic valve controller that uses an existing pressure differential as some or all of the power source for valve operation. In a high pressure environment, such as downhole in an oil or gas well, the pressure differential between the inside of a pipe and the outside of the pipe may be adequately large to drive a linear slide valve. The valve is operated hydraulically by a piston in a bore. When a higher pressure is applied to one end of the bore and a lower pressure to the other end, the piston moves in response to the pressure differential and drives a valve attached to it. If the pressure differential is too small to drive the piston at a sufficiently high speed, a pump is provided to generate a larger pressure differential to be applied. The apparatus is conveniently constructed using multiport valves, which can be rotary valves.

  14. Extreme pressure differences at 0900 NZST and winds across New Zealand

    Science.gov (United States)

    Salinger, M. James; Griffiths, Georgina M.; Gosai, Ashmita

    2005-07-01

    Trends in extremes in station daily sea-level pressure differences at 0900 NZST are examined, and extreme daily wind gusts, across New Zealand, since the 1960s. Annual time series were examined (with indices of magnitude and frequency over threshold percentiles) from the daily indices selected. These follow from earlier indices of normalized monthly mean sea-level pressure differences between station pairs, except the daily indices are not normalized. The frequency statistics quantify the number of extreme zonal (westerly and easterly), or extreme meridional (southerly or northerly), pressure gradient events. The frequency and magnitude of extreme westerly episodes has increased slightly over New Zealand, with a significant increase in the westerly extremes to the south of New Zealand. In contrast, the magnitude and frequency of easterly extremes has decreased over New Zealand, but increased to the south, with some trends weakly significant. The frequency and magnitude of daily southerly extremes has decreased significantly in the region.Extreme daily wind gust events at key climate stations in New Zealand and at Hobart, Australia, are highly likely to be associated with an extreme daily pressure difference. The converse was less likely to hold: extreme wind gusts were not always observed on days with extreme daily pressure difference, probably due to the strong influence that topography has on localized station winds. Significant correlations exist between the frequency indices and both annual-average mean sea-level pressures around the Australasian region and annual-average sea surface temperature (SST) anomalies in the Southern Hemisphere. These correlations are generally stronger for indices of extreme westerly or extreme southerly airflows. Annual-average pressures in the Tasman Sea or Southern Ocean are highly correlated to zonal indices (frequency of extreme westerlies). SST anomalies in the NINO3 region or on either side of the South Island are

  15. Comparative evaluation of pressure generated on a simulated maxillary oral analog by impression materials in custom trays of different spacer designs: An in vitro study.

    Science.gov (United States)

    Chopra, Sakshi; Gupta, Narendra Kumar; Tandan, Amrit; Dwivedi, Ravi; Gupta, Swati; Agarwal, Garima

    2016-01-01

    Literature reveals that masticatory load on denture bearing tissues through complete dentures should be maximum on primary stress bearing areas and least on relief area in accordance with the histology of underlying tissues. A study to validate the existing beliefs was planned to compare the pressure on mucosa using selective pressure technique and minimal pressure technique, with the incorporation of two different impression materials utilizing the pressure sensors during secondary impression procedure. The study was performed using a maxillary analog. Three pressure sensors were imbedded in the oral analog, one in the mid palatine area and the other two in the right and left ridge crest. Custom trays of two different configurations were fabricated. The two impression materials tested were light body and zinc oxide eugenol. A total of 40 impressions were made. A constant weight of 1 kg was placed, and the pressure was recorded as initial and end pressures. A significant difference in the pressure produced using different impression materials was found (P changing the amount of pressure produced. The impression materials used also had a significant role to play on the pressures acting on the tissues during impression procedure. Light body VPS impression material may be recommended to achieve minimal pressure on the denture bearing tissues in both selective as well as minimal pressure techniques.

  16. Does the position or contact pressure of the stethoscope make any difference to clinical blood pressure measurements: an observational study.

    Science.gov (United States)

    Pan, Fan; Zheng, Dingchang; He, Peiyu; Murray, Alan

    2014-12-01

    This study aimed to investigate the effect of stethoscope position and contact pressure on auscultatory blood pressure (BP) measurement. Thirty healthy subjects were studied. Two identical stethoscopes (one under the cuff, the other outside the cuff) were used to simultaneously and digitally record 2 channels of Korotkoff sounds during linear cuff pressure deflation. For each subject, 3 measurements with different contact pressures (0, 50, and 100 mm Hg) on the stethoscope outside the cuff were each recorded at 3 repeat sessions. The Korotkoff sounds were replayed twice on separate days to each of 2 experienced listeners to determine systolic and diastolic BPs (SBP and DBP). Variance analysis was performed to study the measurement repeatability and the effect of stethoscope position and contact pressure on BPs. There was no significant BP difference between the 3 repeat sessions, between the 2 determinations from each listener, between the 2 listeners and between the 3 stethoscope contact pressures (all P > 0.06). There was no significant SBP difference between the 2 stethoscope positions at the 2 lower stethoscope pressures (P = 0.23 and 0.45), but there was a small (0.4 mm Hg, clinically unimportant) significant difference (P = 0.005) at the highest stethoscope pressure. The key result was that, DBP from the stethoscope under the cuff was significantly lower than that from outside the cuff by 2.8 mm Hg (P stethoscope outside the cuff, tends to give a higher DBP than the true intra-arterial pressure, this study could suggest that the stethoscope position under the cuff, and closer to the arterial occlusion, might yield measurements closer to the actual invasive DBP.

  17. Simultaneous compared with sequential blood pressure measurement results in smaller inter-arm blood pressure differences

    NARCIS (Netherlands)

    van der Hoeven, Niels V.; Lodestijn, Sophie; Nanninga, Stephanie; van Montfrans, Gert A.; van den Born, Bert-Jan H.

    2013-01-01

    There are currently few recommendations on how to assess inter-arm blood pressure (BP) differences. The authors compared simultaneous with sequential measurement on mean BP, inter-arm BP differences, and within-visit reproducibility in 240 patients stratified according to age ( <50 or ≥60 years) and

  18. Gender Differences in Behavioral and Neural Responses to Unfairness Under Social Pressure.

    Science.gov (United States)

    Zheng, Li; Ning, Reipeng; Li, Lin; Wei, Chunli; Cheng, Xuemei; Zhou, Chu; Guo, Xiuyan

    2017-10-18

    Numerous studies have revealed the key role of social pressure on individuals' decision-making processes. However, the impact of social pressure on unfairness-related decision-making processes remains unclear. In the present study, we investigated how social pressure modulated men's and women's responses in an ultimatum game. Twenty women and eighteen men played the ultimatum game as responders in the scanner, where fair and unfair offers were tendered by proposers acting alone (low pressure) or by proposers endorsed by three supporters (high pressure). Results showed that men rejected more, whereas women accepted more unfair offers in the high versus low pressure context. Neurally, pregenual anterior cingulate cortex activation in women positively predicted their acceptance rate difference between contexts. In men, stronger right anterior insula activation and increased connectivity between right anterior insula and dorsal anterior cingulate cortex were observed when they receiving unfair offers in the high than low pressure context. Furthermore, more bilateral anterior insula and left dorsolateral prefrontal cortex activations were found when men rejected (relative to accepted) unfair offers in the high than low pressure context. These findings highlighted gender differences in the modulation of behavioral and neural responses to unfairness by social pressure.

  19. Total flying hours and risk of high systolic blood pressure in the civilian pilot in Indonesia

    Directory of Open Access Journals (Sweden)

    Ferdi Afian

    2016-07-01

    Full Text Available Abstrak Latar belakang: Tekanan darah sistolik tinggi di antara pilot sipil antara lain akan menyebabkan gangguan kardiovaskular sehingga akan mengganggu kelancaran penerbangan. Tujuan penelitian ini ialah untuk mengetahui faktor-faktor dominan terhadap tekanan darah sistolik tinggi pada pilot sipil. Metode: Penelitian potong lintang dengan metode sampling purposif pada pilot yang melakukan pemeriksaan kesehatan berkala di Balai Kesehatan Penerbangan pada tanggal 18-29 Mei 2015. Data yang dikumpulkan adalah karakteristik demografi dan pekerjaan, klinis, kebiasaan olahraga, kebiasaan makan, indeks massa tubuh dan riwayat penyakit. Tekanan darah sistolik tinggi ialah tekanan darah sistolik140 mmHg atau lebih. Hasil: Dari 690 pilot yang melakukan pemeriksaan kesehatan berkala, 428 pilot laki-laki bersedia berpartisipasi mengikuti penelitian ini. Usia dan riwayat penyakit hipertensi merupakan faktor risiko dominan yang berhubungan dengan tekanan darah sistolik tinggi. Jika dibandingkan dengan pilot usia 19-39 tahun, yang berusia 40-65 tahun mempunyai 15,1 kali lipat lebih besar risiko terkena tekanan darah sistolik tinggi [rasio odds suaian (ORa= 15,12; p= 0,001]. Pilot dengan riwayat penyakit hipertensi dibandingkan dengan yang tidak ada riwayat memiliki risiko tekanan darah sistolik tinggi 93,2 kali lipat lebih besar (ORa= 93,21; p= 0,001 Kesimpulan: Usia 40-65 tahun dan memiliki riwayat hipertensi meningkatkan risiko tekanan darah sistolik tinggi di antara pilot sipil di Indonesia. Kata kunci: tekanan darah sistolik, total jam terbang, pilot sipil, Indonesia.  Abstract Background: Systolic high blood pressure among civilian pilots among others will cause cardiovascular disease and this condition will disrupt the flight.The purpose of this study was to identified the dominant factors related to high systolic blood pressure in the civilian pilots. Methods: A cross-sectional study with a purposive sampling method on a pilot who performed periodic

  20. Pressure ulcer risk assessment and prevention: what difference does a risk scale make? A comparison between Norway and Ireland.

    Science.gov (United States)

    Johansen, E; Moore, Z; van Etten, M; Strapp, H

    2014-07-01

    To explore similarities and differences in nurses' views on risk assessment practices and preventive care activities in a context where patients' risk of developing pressure ulcers is assessed using clinical judgment (Norway) and a context where patients' risk of developing pressure ulcers is assessed using a formal structured risk assessment combined with clinical judgement (Ireland). A descriptive, qualitative design was employed across two different care settings with a total of 14 health care workers, nine from Norway and five from Ireland. Regardless of whether risk assessment was undertaken using clinical judgment or formal structured risk assessment, identified risk factors, at risk patients and appropriate preventive initiatives discussed by participant were similar across care settings. Furthermore, risk assessment did not necessarily result in the planning and implementation of appropriate pressure ulcer prevention initiatives. Thus, in this instance, use of a formal risk assessment tool does not seem to make any difference to the planning, initiation and evaluation of pressure ulcer prevention strategies. Regardless of the method of risk assessment, patients at risk of developing pressure ulcers are detected, suggesting that the practice of risk assessment should be re-evaluated. Moreover, appropriate preventive interventions were described. However, the missing link between risk assessment and documented care planning is of concern and barriers to appropriate pressure ulcer documentation should be explored further. This work is partly funded by a research grant from the Norwegian Nurses Organisation (NNO) (Norsk Sykepleierforbund NSF) in 2012. The authors have no conflict of interest to declare.

  1. What is Total Quality Management?

    Science.gov (United States)

    Bryan, William A.

    1996-01-01

    Provides a general overview of Total Quality Management (TQM) and explains why there is pressure for change in higher education institutions. Defines TQM and the various themes, tools, and beliefs that make it different from other management approaches. Presents 14 principles and how they might be applied to student affairs. (RJM)

  2. Characteristics of CO/sub 2/ TE-amplifiers with different uv preionization at superatmospheric pressure with doping additives

    Energy Technology Data Exchange (ETDEWEB)

    Huebner, H; Homann, C [Technische Univ. Hannover (Germany, F.R.). Inst. fuer Plasmaphysik

    1977-02-01

    The attainable maximum pressure and the small signal gain are compared at pressures up to 3 bar in a TE-CO/sub 2/ laser amplifier with two preionization systems. It is found that doping with tripopylamine increases the attainable pressure for glow discharges but decreases the small signal gain. At slightly superatmospheric pressure and low doping amount the simple Lamberton-Pearson device gives the best results. For constant input energy the inversion grows with increasing total pressure.

  3. Significant interarm blood pressure difference predicts cardiovascular risk in hypertensive patients

    Science.gov (United States)

    Kim, Su-A; Kim, Jang Young; Park, Jeong Bae

    2016-01-01

    Abstract There has been a rising interest in interarm blood pressure difference (IAD), due to its relationship with peripheral arterial disease and its possible relationship with cardiovascular disease. This study aimed to characterize hypertensive patients with a significant IAD in relation to cardiovascular risk. A total of 3699 patients (mean age, 61 ± 11 years) were prospectively enrolled in the study. Blood pressure (BP) was measured simultaneously in both arms 3 times using an automated cuff-oscillometric device. IAD was defined as the absolute difference in averaged BPs between the left and right arm, and an IAD ≥ 10 mm Hg was considered to be significant. The Framingham risk score was used to calculate the 10-year cardiovascular risk. The mean systolic IAD (sIAD) was 4.3 ± 4.1 mm Hg, and 285 (7.7%) patients showed significant sIAD. Patients with significant sIAD showed larger body mass index (P < 0.001), greater systolic BP (P = 0.050), more coronary artery disease (relative risk = 1.356, P = 0.034), and more cerebrovascular disease (relative risk = 1.521, P = 0.072). The mean 10-year cardiovascular risk was 9.3 ± 7.7%. By multiple regression, sIAD was significantly but weakly correlated with the 10-year cardiovascular risk (β = 0.135, P = 0.008). Patients with significant sIAD showed a higher prevalence of coronary artery disease, as well as an increase in 10-year cardiovascular risk. Therefore, accurate measurements of sIAD may serve as a simple and cost-effective tool for predicting cardiovascular risk in clinical settings. PMID:27310982

  4. Comparative evaluation of pressure generated on a simulated maxillary oral analog by impression materials in custom trays of different spacer designs: An in vitro study

    Directory of Open Access Journals (Sweden)

    Sakshi Chopra

    2016-01-01

    Full Text Available Introduction: Literature reveals that masticatory load on denture bearing tissues through complete dentures should be maximum on primary stress bearing areas and least on relief area in accordance with the histology of underlying tissues. A study to validate the existing beliefs was planned to compare the pressure on mucosa using selective pressure technique and minimal pressure technique, with the incorporation of two different impression materials utilizing the pressure sensors during secondary impression procedure. Materials and Methods: The study was performed using a maxillary analog. Three pressure sensors were imbedded in the oral analog, one in the mid palatine area and the other two in the right and left ridge crest. Custom trays of two different configurations were fabricated. The two impression materials tested were light body and zinc oxide eugenol. A total of 40 impressions were made. A constant weight of 1 kg was placed, and the pressure was recorded as initial and end pressures. Results: A significant difference in the pressure produced using different impression materials was found (P < 0.001. Light body vinyl polysiloxane produced significantly lesser pressure than zinc oxide eugenol impression materials. The presence of relief did affect the magnitude of pressure at various locations. Conclusion: All impression materials produced pressure during maxillary edentulous impression making. Tray modification is an important factor in changing the amount of pressure produced. The impression materials used also had a significant role to play on the pressures acting on the tissues during impression procedure. Clinical Implication: Light body VPS impression material may be recommended to achieve minimal pressure on the denture bearing tissues in both selective as well as minimal pressure techniques.

  5. Oscillometric blood pressure measurements: differences between measured and calculated mean arterial pressure.

    NARCIS (Netherlands)

    Kiers, H.D.; Hofstra, J.M.; Wetzels, J.F.M.

    2008-01-01

    Mean arterial pressure (MAP) is often used as an index of overall blood pressure. In recent years, the use of automated oscillometric blood pressure measurement devices is increasing. These devices directly measure and display MAP; however, MAP is often calculated from systolic blood pressure (SBP)

  6. Nanocrystallization in Al85Ce8Ni5Co2 amorphous alloy obtained by different strain rate during high pressure torsion

    International Nuclear Information System (INIS)

    Henits, P.; Kovacs, Zs.; Schafler, E.; Varga, L.K.; Labar, J.L.; Revesz, A.

    2010-01-01

    In order to elucidate the role of total strain and strain rate during high pressure torsion of Al 85 Ce 8 Ni 5 Co 2 metallic glass, different deformation conditions were applied to devitrify the as-quenched alloy. The disk-shaped specimens were characterized by X-ray diffraction, transmission electron microscopy and thermal analysis.

  7. Takotsubo cardiomyopathy precipitated by negative pressure pulmonary oedema following total thyroidectomy

    Directory of Open Access Journals (Sweden)

    K S Bharathi

    2016-01-01

    Full Text Available 'Takotsubo cardiomyopathy (TCM' or 'stress cardiomyopathy' is a reversible cardiomyopathy that is precipitated by intense emotional or physical stress. This syndrome is characterised by symptoms mimicking acute coronary syndrome with transient systolic dysfunction associated with regional wall motion abnormalities, which extend beyond a single coronary vascular bed in the absence of obstructive coronary vascular disease. The presentation of TCM and myocardial infarction is similar with sudden onset of chest pain, breathlessness as well as abnormalities in both the electrocardiogram and cardiac enzymes. It is difficult to differentiate between the two until cardiac catheterisation establishes the diagnosis. We report a case of TCM in a post-menopausal female, precipitated by negative pressure pulmonary oedema following total thyroidectomy in whom timely cardiac catheterisation established the diagnosis and influenced the management. Heightened awareness of this unique cardiomyopathy is essential to have a high index of suspicion in at-risk population for the prompt diagnosis of stress-related cardiomyopathy syndromes occurring in the perioperative period.

  8. The difference in blood pressure readings between arms and survival: primary care cohort study.

    Science.gov (United States)

    Clark, Christopher E; Taylor, Rod S; Shore, Angela C; Campbell, John L

    2012-03-20

    To determine whether a difference in systolic blood pressure readings between arms can predict a reduced event free survival after 10 years. Cohort study. Rural general practice in Devon, United Kingdom. 230 people receiving treatment for hypertension in primary care. Bilateral blood pressure measurements recorded at three successive surgery attendances. Cardiovascular events and deaths from all causes during a median follow-up of 9.8 years. At recruitment 24% (55/230) of participants had a mean interarm difference in systolic blood pressure of 10 mm Hg or more and 9% (21/230) of 15 mm Hg or more; these differences were associated with an increased risk of all cause mortality (adjusted hazard ratio 3.6, 95% confidence interval 2.0 to 6.5 and 3.1, 1.6 to 6.0, respectively). The risk of death was also increased in 183 participants without pre-existing cardiovascular disease with an interarm difference in systolic blood pressure of 10 mm Hg or more or 15 mm Hg or more (2.6, 1.4 to 4.8 and 2.7, 1.3 to 5.4). An interarm difference in diastolic blood pressure of 10 mm Hg or more was weakly associated with an increased risk of cardiovascular events or death. Differences in systolic blood pressure between arms can predict an increased risk of cardiovascular events and all cause mortality over 10 years in people with hypertension. This difference could be a valuable indicator of increased cardiovascular risk. Bilateral blood pressure measurements should become a routine part of cardiovascular assessment in primary care.

  9. Effect of sintering pressure on structure and magnetic properties of Zn0.99Ni0.01O bulk samples synthesized under different pressures

    International Nuclear Information System (INIS)

    Wang, Yongqiang; Yuan, Chaosheng; Su, Lei; Wang, Zheng; Hao, Junhong; Ren, Yufen

    2015-01-01

    A series of Zn 0.99 Ni 0.01 O bulk samples were prepared by a coprecipitation method, and then sintered at 600 °C under various pressures from normal pressure(NP) to 3 GPa. The effects of sintering pressure (P S ) on the structure, morphology and magnetic properties of the doping samples were investigated in detail. The XRD and HRTEM results reveal that all samples are of single-phase hexagonal structure. Compared with the sample sintered at normal pressure, the lattice parameters a and c of the samples sintered at high pressures (HP) show a sharply decrease. With the increase of sintering pressure, the particle size gradually increases as well as the particles get closer to each other. At 300 K, the sample sintered at normal pressure shows a superparamagnetic-like behavior, while the samples sintered at high pressures display typical ferromagnetic behaviors. The saturation magnetization of the samples sintered at high pressures is three orders of magnitude larger than that of the one sintered at normal pressure. Our results reveal that an appropriate sintering pressure can tune the magnetic properties of Ni-doped ZnO system by changing the lattice parameters, particle size and inter-particle spacing, which may be helpful to the practical applications. - Highlights: • A series of Zn 0.99 Ni 0.01 O bulk samples were sintered in different pressures. • The lattice constants of the samples sintered at high pressure clearly decrease. • The particle size increases gradually with the increase of sintering pressure. • The samples sintered at different pressures show different magnetic behaviors. • Appropriate sintering pressure can tune the magnetic properties of Zn–Ni–O system

  10. Measurement of total occlusal convergence of 3 different tooth preparations in 4 different planes by dental students.

    Science.gov (United States)

    Yoon, Stephan S; Cheong, Chan; Preisser, John; Jun, Sangho; Chang, Brian M; Wright, Robert F

    2014-08-01

    Total occlusal convergence of crown preparation is an important didactic and clinical concept in dental education. The purpose of this study was to compare the discrepancy between the total occlusal convergence of dental students' typodont crown preparations and the ideal range (4 to 10 degrees) in 3 different regions of the mouth and in 4 different planes of the teeth. The dental students of the Class of 2012 at Harvard School of Dental Medicine were asked to prepare typodont teeth for crowns on 3 different teeth, the maxillary left central incisor (ceramic), mandibular left first molar (complete metal), and mandibular left first premolar (metal ceramic), during their third year preclinical summative examination and the Comprehensive Clinical Examination in their fourth year. Eighteen students prepared 3 teeth in their third and fourth years, whereas 19 students participated only in their fourth year, for a total of 55 sets of 3 teeth. By using custom fit die bases to reproduce the position, a novel procedure of measuring each tooth was accomplished in 4 different planes: the faciolingual, mesiodistal, mesiofacial-distolingual, and mesiolingual-distofacial. The total occlusal convergence of each image was measured with a computer screen protractor. The gingival 2 mm of the axial wall was used to determine the taper of each wall. Linear mixed model analysis was used to estimate and compare the total occlusal convergences of different teeth and planes (α=.05). Bonferroni corrections were used to adjust for post hoc multiple comparisons. The mean total occlusal convergence varied by tooth and plane (2-way interaction; Pplanes; the model-predicted 99% CIs for the total occlusal convergence were as follows: faciolingual (12.7, 19.4), mesiodistal (14.0, 19.3), mesiofacial-distolingual (13,4, 19.4), and mesiolingual-distofacial (13.7, 19.1). For the central incisor, 99% CIs for the total occlusal convergence were (15.9, 24.4) for the faciolingual measurement, providing

  11. Distinguishing Different Stages of Parkinson’s Disease Using Composite Index of Speed and Pen-Pressure of Sketching a Spiral

    Directory of Open Access Journals (Sweden)

    Poonam Zham

    2017-09-01

    Full Text Available The speed and pen-pressure while sketching a spiral are lower among Parkinson’s disease (PD patients with higher severity of the disease. However, the correlation between these features and the severity level (SL of PD has been reported to be 0.4. There is a need for identifying parameters with a stronger correlation for considering this for accurate diagnosis of the disease. This study has proposed the use of the Composite Index of Speed and Pen-pressure (CISP of sketching as a feature for analyzing the severity of PD. A total of 28 control group (CG and 27 PD patients (total 55 participants were recruited and assessed for Unified Parkinson’s Disease Rating Scale (UPDRS. They drew guided Archimedean spiral on an A3 sheet. Speed, pen-pressure, and CISP were computed and analyzed to obtain their correlation with severity of the disease. The correlation of speed, pen-pressure, and CISP with the severity of PD was −0.415, −0.584, and −0.641, respectively. Mann–Whitney U test confirmed that CISP was suitable to distinguish between PD and CG, while non-parametric k-sample Kruskal–Wallis test confirmed that it was significantly different for PD SL-1 and PD SL-3. This shows that CISP during spiral sketching may be used to differentiate between CG and PD and between PD SL-1 and PD SL-3 but not SL-2.

  12. Office blood pressure or ambulatory blood pressure for the prediction of cardiovascular events.

    Science.gov (United States)

    Mortensen, Rikke Nørmark; Gerds, Thomas Alexander; Jeppesen, Jørgen Lykke; Torp-Pedersen, Christian

    2017-11-21

    To determine the added value of (i) 24-h ambulatory blood pressure relative to office blood pressure and (ii) night-time ambulatory blood pressure relative to daytime ambulatory blood pressure for 10-year person-specific absolute risks of fatal and non-fatal cardiovascular events. A total of 7927 participants were included from the International Database on Ambulatory blood pressure monitoring in relation to Cardiovascular Outcomes. We used cause-specific Cox regression to predict 10-year person-specific absolute risks of fatal and non-fatal cardiovascular events. Discrimination of 10-year outcomes was assessed by time-dependent area under the receiver operating characteristic curve (AUC). No differences in predicted risks were observed when comparing office blood pressure and ambulatory blood pressure. The median difference in 10-year risks (1st; 3rd quartile) was -0.01% (-0.3%; 0.1%) for cardiovascular mortality and -0.1% (-1.1%; 0.5%) for cardiovascular events. The difference in AUC (95% confidence interval) was 0.65% (0.22-1.08%) for cardiovascular mortality and 1.33% (0.83-1.84%) for cardiovascular events. Comparing daytime and night-time blood pressure, the median difference in 10-year risks was 0.002% (-0.1%; 0.1%) for cardiovascular mortality and -0.01% (-0.5%; 0.2%) for cardiovascular events. The difference in AUC was 0.10% (-0.08 to 0.29%) for cardiovascular mortality and 0.15% (-0.06 to 0.35%) for cardiovascular events. Ten-year predictions obtained from ambulatory blood pressure are similar to predictions from office blood pressure. Night-time blood pressure does not improve 10-year predictions obtained from daytime measurements. For an otherwise healthy population sufficient prognostic accuracy of cardiovascular risks can be achieved with office blood pressure. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2017. For permissions, please email: journals.permissions@oup.com.

  13. Gender difference in blood pressure, blood sugar, and cholesterol in young adults with comparable routine physical exertion

    Directory of Open Access Journals (Sweden)

    T S Anish

    2013-01-01

    Full Text Available Context: Gender differences in the risk of developing non-communicable diseases (NCD are a matter of debate. The susceptibility of a woman to NCD should be evaluated taking into consideration the social factors that limit the physical activity among women. It will be interesting to note what will happen if women are allowed to take part in physical exercise to the extent of men. Aims: To find out the gender difference in the pattern of the clinical and biochemical indices related to NCD in young adults with comparable daily physical activity. Settings and Design: This is an institution-based cross-sectional study and the setting was Lekshmibhai National College for Physical Education (LNCPE, Thiruvananthapuram, Kerala, India. Materials and Methods: The study participants were students who were regularly involved in more than three hours of physical exercise daily at least for the previous one year. The information on socio-demography, anthropometry, and blood pressure was recorded. Blood samples were taken for laboratory examination. Results: Out of 150 students registered, 126 (84% in the age group of 17 to 25 years who fulfilled the eligibility criteria were studied. Fifty-five (43.7% of them were women. Systolic blood pressure, fasting blood sugar, and low-density lipoprotein were found significantly lower in women. No significant difference was noted in the case of diastolic blood pressure and total cholesterol. Conclusion: Gender differences exist for NCD risk factors among young adults with comparable physical activity and physical exertion seems to be more protective for females.

  14. Inter-arm blood pressure differences compared with ambulatory monitoring: a manifestation of the 'white-coat' effect?

    Science.gov (United States)

    Martin, Una; Holder, Roger; Hodgkinson, James; McManus, Richard

    2013-02-01

    Inter-arm difference in blood pressure of >10 mmHg is associated with peripheral vascular disease, but it is unclear how much of the difference in sequential right and left arm blood pressure measurements might be due to a 'white-coat' effect. To use ambulatory blood pressure monitoring (ABPM) to better understand the clinical significance of inter-arm differences in blood pressure. Retrospective study in a teaching hospital in Birmingham. Anonymised clinical data collected from 784 patients attending a single hospital-based hypertension clinic were retrospectively analysed. Each participant had blood pressure measured sequentially in both arms, followed by ABPM over the subsequent 24 hours. Data were available for 710 (91%) patients, of whom 39.3% (279) had a blood pressure difference of 10 mmHg or more between each arm. Compared to daytime systolic ABPM, the difference was 25.1 mmHg using the arm with the highest reading, but only 15.5 mmHg if the lower reading was taken (mean difference 9.6 mmHg (95% confidence interval [CI] = 9.0 mmHg to 10.3 mmHg)). However, differences between mean right (20.7 mmHg) or left (19.9 mmHg) arm blood pressure and daytime systolic ABPM were very similar. Compared with ABPM, use of the higher of the left and right arm readings measured sequentially appears to overestimate true mean blood pressure. As there is no significant difference in the extent of disparity with ABPM by left or right arm, this is unlikely to be due to arm dominance and may be due to the 'white-coat' effect reducing blood pressure on repeated measurement. Where a large inter-arm blood pressure difference is detected with sequential measurement, healthcare professionals should re-measure the blood pressure in the original arm.

  15. Influence of the Pressure Difference and Door Swing on Heavy Contaminants Migration between Rooms.

    Science.gov (United States)

    Hendiger, Jacek; Chludzińska, Marta; Ziętek, Piotr

    2016-01-01

    This paper presents the results of investigations whose aim was to describe the influence of the pressure difference level on the ability of contaminants migration between neighbouring rooms in dynamic conditions associated with door swing. The analysis was based on airflow visualization made with cold smoke, which simulated the heavy contaminants. The test room was pressurized to a specific level and then the door was opened to observe the trail of the smoke plume in the plane of the door. The door was opened in both directions: to the positively and negatively pressurized room. This study focuses on the visualization of smoke plume discharge and an uncertainty analysis is not applicable. Unlike other studies which focus on the analysis of pressure difference, the present study looks at the contaminants which are heavier than air and on "pumping out" the contaminants by means of door swing. Setting the proper level of pressure difference between the contaminated room and the neighbouring rooms can prove instrumental in ensuring protection against toxic contaminants migration. This study helped to establish the threshold of pressure difference necessary to reduce migration of heavy contaminants to neighbouring rooms.

  16. Pressure balance between lobe and plasma sheet

    International Nuclear Information System (INIS)

    Baumjohann, W.; Paschmann, G.; Luehr, H.

    1990-01-01

    Using eight months of AMPTE/IRM plasma and magnetic field data, the authors have done a statistical survey on the balance of total (thermal and magnetic) pressure in the Earth's plasma sheet and tail lobe. About 300,000 measurements obtained in the plasma sheet and the lobe were compared for different levels of magnetic activity as well as different distances from the Earth. The data show that lobe and plasma sheet pressure balance very well. Even in the worst case they do not deviate by more than half of the variance in the data itself. Approximately constant total pressure was also seen during a quiet time pass when IRM traversed nearly the whole magnetotail in the vertical direction, from the southern hemisphere lobe through the neutral sheet and into the northern plasma sheet boundary layer

  17. Radiation pressure induced difference-sideband generation beyond linearized description

    OpenAIRE

    Xiong, Hao; Fan, Y. W.; Yang, X.; Wu, Y.

    2016-01-01

    We investigate radiation-pressure induced generation of the frequency components at the difference-sideband in an optomechanical system, which beyond the conventional linearized description of optomechanical interactions between cavity fields and the mechanical oscillation. We analytically calculate amplitudes of these signals, and identify a simple square-root law for both the upper and lower difference-sideband generation which can describe the dependence of the intensities of these signals...

  18. Comparative study of interventricular phase difference and pressure gradient in cases of isolated ventricular septal defect

    Energy Technology Data Exchange (ETDEWEB)

    Elhaddad, SH; Moustafa, H; Ziada, G; Seleem, Z; Elsabban, KH; Mahmoud, F [Nuclear medicine department and pediatric cardiology department Faculty of medicine, Cairo university, Cairo, (Egypt)

    1995-10-01

    One hundred and fifty patients with isolated VSD were evaluated by radionuclide MUGA study and Echo-Doppler. Difference between phase angle of the right and left ventricles as detected by MUGA had been divided into main four groups according to pressure gradient between the two ventricles : group I (with pressure gradient {<=}30 mmHg and phase difference 80.10 degree{+-}34.1), group III (with pressure gradient > 70 mmHg and phase difference -0.5 degree {+-} 8.4). It has been found that there was a significant difference between the 4 groups as regards right - to - left ventricular phase difference (P<0.0001). There was significant delay in emptying of right ventricle in groups with pressure gradient < 50 mmHg. Regression analysis revealed inverse correlation between right -to- left ventricular phase difference with changes in pressure gradient (r= 0.81). Similarly, significant correlation had been found between right -to-left ventricular phase difference in relation Qp/Qs (r=0.85); conclusion: interventricular phase difference can be used to evaluate interventricular pressure gradient in cases of isolated VSD. 4 figs., 2 tabs.

  19. Interarm Difference in Blood Pressure: Reproducibility and Association with Peripheral Vascular Disease

    Directory of Open Access Journals (Sweden)

    Jesper Mehlsen

    2014-01-01

    Full Text Available The present study aimed at examining the interarm difference in blood pressure and its use as an indicator of peripheral arterial disease (PAD. Data were included from consecutive patients referred from their general practitioner to our vascular laboratory for possible PAD aged 50 years or older without known cardiac disease, renal disease, or diabetes mellitus. 824 patients (453 women with mean age of 72 years (range: 50–101 were included. 491 patients had a diagnosis of hypertension and peripheral arterial disease (PAD was present in 386 patients. Systolic blood pressure was 143 ± 24 mmHg and 142 ± 24 mmHg on the right and left arm, respectively (P=0.015. The interarm difference was greater in patients with hypertension (P=0.002 and PAD (P20 mmHg. This study confirmed the presence of a systematic but clinically insignificant difference in systolic blood pressure between arms. The interarm difference was larger in hypertension and PAD. Consistent lateralisation is present for differences ≥20 mmHg and an interarm difference >25 mmHg is a reliable indicator of PAD in the legs.

  20. Differences in sampling techniques on total post-mortem tryptase.

    Science.gov (United States)

    Tse, R; Garland, J; Kesha, K; Elstub, H; Cala, A D; Ahn, Y; Stables, S; Palmiere, C

    2017-11-20

    The measurement of mast cell tryptase is commonly used to support the diagnosis of anaphylaxis. In the post-mortem setting, the literature recommends sampling from peripheral blood sources (femoral blood) but does not specify the exact sampling technique. Sampling techniques vary between pathologists, and it is unclear whether different sampling techniques have any impact on post-mortem tryptase levels. The aim of this study is to compare the difference in femoral total post-mortem tryptase levels between two sampling techniques. A 6-month retrospective study comparing femoral total post-mortem tryptase levels between (1) aspirating femoral vessels with a needle and syringe prior to evisceration and (2) femoral vein cut down during evisceration. Twenty cases were identified, with three cases excluded from analysis. There was a statistically significant difference (paired t test, p sampling methods. The clinical significance of this finding and what factors may contribute to it are unclear. When requesting post-mortem tryptase, the pathologist should consider documenting the exact blood collection site and method used for collection. In addition, blood samples acquired by different techniques should not be mixed together and should be analyzed separately if possible.

  1. Predicting Electrocardiogram and Arterial Blood Pressure Waveforms with Different Echo State Network Architectures

    Science.gov (United States)

    2014-11-01

    Predicting Electrocardiogram and Arterial Blood Pressure Waveforms with Different Echo State Network Architectures Allan Fong, MS1,3, Ranjeev...the medical staff in Intensive Care Units. The ability to predict electrocardiogram and arterial blood pressure waveforms can potentially help the...type of neural network for mining, understanding, and predicting electrocardiogram and arterial blood pressure waveforms. Several network

  2. Different centre of pressure patterns within the golf stroke II: group-based analysis.

    Science.gov (United States)

    Ball, K A; Best, R J

    2007-05-01

    Although the golf coaching literature stresses the importance of weight transfer during the swing, research has been conflicting or lacking statistical support. A potential problem with previous studies is that no attempt was made to account for different movement strategies in the golf swing. This study evaluated the relationship between centre of pressure measures and club head velocity within two previously identified swing styles, the "Front Foot" and "Reverse" styles. Thirty-nine Front Foot golfers and 19 Reverse golfers performed swings with a driver while standing on two force plates. From the force plate data, centre of pressure displacement, velocity, range, and timing parameters were calculated. Correlation and regression analysis indicated that a larger range of centre of pressure and a more rapid centre of pressure movement in the downswing was associated with a larger club head velocity at ball contact for the Front Foot group. For the Reverse golfers, positioning the centre of pressure further from the back foot at late backswing and a more rapid centre of pressure transfer towards the back foot at ball contact was associated with a larger club head velocity at ball contact. This study has highlighted the importance of identifying different movement strategies before evaluating performance measures, as different parameters were found to be important for the Front Foot and Reverse styles.

  3. [The interarm blood pressure difference in the critically ill patient].

    Science.gov (United States)

    Valls Matarín, Josefa; del Cotillo Fuente, Mercedes; Quintana Riera, Salvador; de la Sierra Iserte, Alejandro

    2014-02-04

    To evaluate the prevalence of a difference in systolic blood pressure (SBPd) ≥ 10 mmHg between arms in patients admitted in a Critical Care Unit and to examine the clinical characteristics associated with such blood pressure difference. Observational cross-sectional study. Two blood pressure measurements in each arm were carried out at unit admission. The firstly measured arm was chosen at random. One-hundred and sixty-eight patients were studied, with a mean age of 61 (SD=16), 67.3% male and 45% with a previous hypertension diagnosis. On admission, 27.4% presented SBPd ≥ 10 mmHg. Among them, 54% had higher SBP in the right arm and 46% in the left one. A SBPd ≥ 10 mmHg was associated with a previous hypertension diagnosis (67.4 versus 36.9%; Parms. This feature is associated with a previous hypertension diagnosis and reduced consciousness. It should be assessed in the future if the choice of a control arm would help improve patient's care as it would become a more accurate guide for hemodynamic management. Copyright © 2012 Elsevier España, S.L. All rights reserved.

  4. Comparison of Comfort and Effectiveness of Total Face Mask and Oronasal Mask in Noninvasive Positive Pressure Ventilation in Patients with Acute Respiratory Failure: A Clinical Trial.

    Science.gov (United States)

    Sadeghi, Somayeh; Fakharian, Atefeh; Nasri, Peiman; Kiani, Arda

    2017-01-01

    Background . There is a growing controversy about the use of oronasal masks (ONM) or total facemask (TFM) in noninvasive positive pressure ventilation (NPPV), so we designed a trial to compare the uses of these two masks in terms of effectiveness and comfort. Methods . Between February and November 2014, a total of 48 patients with respiratory failure were studied. Patients were randomized to receive NPPV via ONM or TFM. Data were recorded at 60 minutes and six and 24 hours after intervention. Patient comfort was assessed using a questionnaire. Data were analyzed using t -test and chi-square test. Repeated measures ANOVA and Mann-Whitney U test were used to compare clinical and laboratory data. Results . There were no differences in venous blood gas (VBG) values between the two groups ( P > 0.05). However, at six hours, TFM was much more effective in reducing the partial pressure of carbon dioxide (PCO2) ( P = 0.04). Patient comfort and acceptance were statistically similar in both groups ( P > 0.05). Total time of NPPV was also similar in the two groups ( P > 0.05). Conclusions . TFM was superior to ONM in acute phase of respiratory failure but not once the patients were out of acute phase.

  5. Comparison of Comfort and Effectiveness of Total Face Mask and Oronasal Mask in Noninvasive Positive Pressure Ventilation in Patients with Acute Respiratory Failure: A Clinical Trial

    Directory of Open Access Journals (Sweden)

    Somayeh Sadeghi

    2017-01-01

    Full Text Available Background. There is a growing controversy about the use of oronasal masks (ONM or total facemask (TFM in noninvasive positive pressure ventilation (NPPV, so we designed a trial to compare the uses of these two masks in terms of effectiveness and comfort. Methods. Between February and November 2014, a total of 48 patients with respiratory failure were studied. Patients were randomized to receive NPPV via ONM or TFM. Data were recorded at 60 minutes and six and 24 hours after intervention. Patient comfort was assessed using a questionnaire. Data were analyzed using t-test and chi-square test. Repeated measures ANOVA and Mann–Whitney U test were used to compare clinical and laboratory data. Results. There were no differences in venous blood gas (VBG values between the two groups (P>0.05. However, at six hours, TFM was much more effective in reducing the partial pressure of carbon dioxide (PCO2 (P=0.04. Patient comfort and acceptance were statistically similar in both groups (P>0.05. Total time of NPPV was also similar in the two groups (P>0.05. Conclusions. TFM was superior to ONM in acute phase of respiratory failure but not once the patients were out of acute phase.

  6. Inter-arm blood pressure differences compared with ambulatory monitoring: a manifestation of the ‘white-coat’ effect?

    Science.gov (United States)

    Martin, Una; Holder, Roger; Hodgkinson, James; McManus, Richard

    2013-01-01

    Background Inter-arm difference in blood pressure of >10 mmHg is associated with peripheral vascular disease, but it is unclear how much of the difference in sequential right and left arm blood pressure measurements might be due to a ‘white-coat’ effect. Aim To use ambulatory blood pressure monitoring (ABPM) to better understand the clinical significance of inter-arm differences in blood pressure. Design and setting Retrospective study in a teaching hospital in Birmingham. Method Anonymised clinical data collected from 784 patients attending a single hospital-based hypertension clinic were retrospectively analysed. Each participant had blood pressure measured sequentially in both arms, followed by ABPM over the subsequent 24 hours. Result Data were available for 710 (91%) patients, of whom 39.3% (279) had a blood pressure difference of 10 mmHg or more between each arm. Compared to daytime systolic ABPM, the difference was 25.1 mmHg using the arm with the highest reading, but only 15.5 mmHg if the lower reading was taken (mean difference 9.6 mmHg (95% confidence interval [CI] = 9.0 mmHg to 10.3 mmHg)). However, differences between mean right (20.7 mmHg) or left (19.9 mmHg) arm blood pressure and daytime systolic ABPM were very similar. Conclusion Compared with ABPM, use of the higher of the left and right arm readings measured sequentially appears to overestimate true mean blood pressure. As there is no significant difference in the extent of disparity with ABPM by left or right arm, this is unlikely to be due to arm dominance and may be due to the ‘white-coat’ effect reducing blood pressure on repeated measurement. Where a large inter-arm blood pressure difference is detected with sequential measurement, healthcare professionals should re-measure the blood pressure in the original arm. PMID:23561681

  7. Nutrient digestibility and growth in rainbow trout (Oncorhynchus mykiss) are impaired by short term exposure to moderate supersaturation in total gas pressure

    DEFF Research Database (Denmark)

    Skov, Peter Vilhelm; Pedersen, Lars-Flemming; Pedersen, Per Bovbjerg

    2013-01-01

    Excess levels of dissolved nitrogen gas (N2) may occur in recirculating aquaculture systems, as a result of aeration efforts, localized occurrences of denitrification, or from insufficient degassing of makeup water. If levels of dissolved N2 are sufficiently high, or if oxygen (O2) is also...... maintained at or above saturation, this leads to a supersaturation in total gas pressure (TGP). Depending on severity, total gas pressures above saturation may lead to gas bubble trauma, evident by visual inspection of the fish. Physiological effects of subclinical levels of TGP are not well known and have...... not been investigated for rainbow trout. The present study examined the effects of N2 supersaturation, with or without simultaneous excess TGP. Supersaturation with N2 (ΔP 22mmHg) without total gas supersaturation (ΔTGP −6mmHg) did not have any significant effects on feed intake, feed conversion or growth...

  8. Differences in center of pressure trajectory between normal and steppage gait

    Science.gov (United States)

    Jamshidi, Nima; Rostami, Mostafa; Najarian, Siamak; Menhaj, Mohammad Bagher; Saadatnia, Mohammad; Salami, Firooz

    2010-01-01

    BACKGROUND: This pilot study aimed to assess the differences in center of pressure trajectory in neuropathic patients with steppage gait. Steppage gait has previously been evaluated by several biomechanical methods, but plantar pressure distribution has been much less studied. The purpose of this study was to analyze the changes in center of pressure trajectory using a force plate. METHODS: The steppage gait group was selected from the patients using drop foot brace (25 male) and the control group was selected from Isfahan university students (20 male). They walked at self- selected speed at a mean of ten trials (+2) to collect the center of pressure using a force plate. Center of pressure patterns were categorized into four patterns based on the center of pressure displacement magnitude (spatial features) through time (temporal features) when the longitudinal axis of the insole was plotted as the Y- axis and the transverse axis of the insole as X- axis during stance phase. RESULTS: The horizontal angle measured from center of pressure linear regression was positive in the control group (4.6 ± 2.4) (p < 0.005), but negative in the patient group (- 2.3 ± 1.6) (p < 0.005). CONCLUSIONS: The finding of this research measured center of pressure trajectory in steppage gait over time, which is useful for designing better shoe sole and also orthopaedic device and better understanding of stability in patients with drop foot. PMID:21526056

  9. Differences in center of pressure trajectory between normal and steppage gait

    Directory of Open Access Journals (Sweden)

    Nima Jamshidi

    2010-01-01

    Full Text Available Background: This pilot study aimed to assess the differences in center of pressure trajectory in neuropathic patients with steppage gait. Steppage gait has previously been evaluated by several biomechanical methods, but plantar pressure distribution has been much less studied. The purpose of this study was to analyze the changes in center of pressure tra-jectory using a force plate. Methods: The steppage gait group was selected from the patients using drop foot brace (25 male and the control group was selected from Isfahan university students (20 male. They walked at self- selected speed at a mean of ten tri-als (+2 to collect the center of pressure using a force plate. Center of pressure patterns were categorized into four pat-terns based on the center of pressure displacement magnitude (spatial features through time (temporal features when the longitudinal axis of the insole was plotted as the Y- axis and the transverse axis of the insole as X- axis during stance phase. Results: The horizontal angle measured from center of pressure linear regression was positive in the control group (4.6 ± 2.4 (p < 0.005, but negative in the patient group (- 2.3 ± 1.6 (p < 0.005. Conclusions: The finding of this research measured center of pressure trajectory in steppage gait over time, which is useful for designing better shoe sole and also orthopaedic device and better understanding of stability in patients with drop foot.

  10. Initial in vitro testing of a paediatric continuous-flow total artificial heart.

    Science.gov (United States)

    Fukamachi, Kiyotaka; Karimov, Jamshid H; Horvath, David J; Sunagawa, Gengo; Byram, Nicole A; Kuban, Barry D; Moazami, Nader

    2018-06-01

    Mechanical circulatory support has become standard therapy for adult patients with end-stage heart failure; however, in paediatric patients with congenital heart disease, the options for chronic mechanical circulatory support are limited to paracorporeal devices or off-label use of devices intended for implantation in adults. Congenital heart disease and cardiomyopathy often involve both the left and right ventricles; in such cases, heart transplantation, a biventricular assist device or a total artificial heart is needed to adequately sustain both pulmonary and systemic circulations. We aimed to evaluate the in vitro performance of the initial prototype of our paediatric continuous-flow total artificial heart. The paediatric continuous-flow total artificial heart pump was downsized from the adult continuous-flow total artificial heart configuration by a scale factor of 0.70 (1/3 of total volume) to enable implantation in infants. System performance of this prototype was evaluated using the continuous-flow total artificial heart mock loop set to mimic paediatric circulation. We generated maps of pump performance and atrial pressure differences over a wide range of systemic vascular resistance/pulmonary vascular resistance and pump speeds. Performance data indicated left pump flow range of 0.4-4.7 l/min at 100 mmHg delta pressure. The left/right atrial pressure difference was maintained within ±5 mmHg with systemic vascular resistance/pulmonary vascular resistance ratios between 1.4 and 35, with/without pump speed modulation, verifying expected passive self-regulation of atrial pressure balance. The paediatric continuous-flow total artificial heart prototype met design requirements for self-regulation and performance; in vivo pump performance studies are ongoing.

  11. Inter-arm blood pressure differences in young, healthy patients.

    Science.gov (United States)

    Grossman, Alon; Prokupetz, Alex; Gordon, Barak; Morag-Koren, Nira; Grossman, Ehud

    2013-08-01

    The prevalence and magnitude of inter-arm BP difference (IAD) in young healthy patients is not well characterized. Flight academy applicants and designated aviators undergo annual evaluation that includes blood pressure (BP) measurement on both arms. All BP measurements performed from January 1, 2012, to April 30, 2012, were recorded and IAD was calculated. Results were compared between patients in whom BP was initially measured in the right arm (group 1), those in whom BP was initially measured in the left arm (group 2), and those in whom the arm in which BP was initially measured was not recorded (group 3). A total of 877 healthy patients had BP measured during the study period. In the entire group, mean systolic BP was the same in both arms. Absolute IAD was 5.6±5.5 mm Hg for systolic and 4.7±4.5 mm Hg for diastolic BP. IAD >10 mm Hg was recorded in 111 (12.6%) and 77 (8.8%) patients for systolic and diastolic BP, respectively. IAD was the same in the 3 groups and was unrelated to age, body mass index, and heart rate, but was related to systolic BP. IAD is common in young healthy patients, is not dependent on which arm was measured first, and unrelated to age, body mass index, and heart rate. © 2013 Wiley Periodicals, Inc.

  12. Effects of long-term low atmospheric pressure on gas exchange and growth of lettuce

    Science.gov (United States)

    Tang, Yongkang; Guo, Shuangsheng; Dong, Wenping; Qin, Lifeng; Ai, Weidang; Lin, Shan

    2010-09-01

    The objectives of this research were to determine photosynthesis, evapotranspiration and growth of lettuce at long-term low atmospheric pressure. Lettuce ( Lactuca sativa L . cv. Youmaicai) plants were grown at 40 kPa total pressure (8.4 kPa p) or 101 kPa total pressure (20.9 kPa p) from seed to harvest for 35 days. Germination rate of lettuce seeds decreased by 7.6% at low pressure, although this was not significant. There was no significant difference in crop photosynthetic rate between hypobaria and ambient pressure during the 35-day study. The crop evapotranspiration rate was significantly lower at low pressure than that at ambient pressure from 20 to 30 days after planting (DAP), but it had no significant difference before 20 DAP or after 30 DAP. The growth cycle of lettuce plants at low pressure was delayed. At low pressure, lettuce leaves were curly at the seedling stage and this disappeared gradually as the plants grew. Ambient lettuce plants were yellow and had an epinastic growth at harvest. The shoot height, leaf number, leaf length and shoot/root ratio were lower at low pressure than those at ambient pressure, while leaf area and root growth increased. Total biomass of lettuce plants grown at two pressures had no significant difference. Ethylene production at low pressure decreased significantly by 38.8% compared with ambient pressure. There was no significant difference in microelements, nutritional phytochemicals and nitrate concentrations at the two treatments. This research shows that lettuce can be grown at long-term low pressure (40 kPa) without significant adverse effects on seed germination, gas exchange and plant growth. Furthermore, ethylene release was reduced in hypobaria.

  13. Experimental study an a low pressure solar still

    International Nuclear Information System (INIS)

    Sriram, V.; Kalidasa Murugavel, K.; Samuel Hansen, R.

    2013-01-01

    In this work, a low pressure, single basin double slope Solar Still was fabricated and tested for different depths and with different wick and porous materials. A vacuum pump was used to maintain low pressure inside the still. External condenser was used to condense the vapor with raw water as cooling fluid. The performance of the low pressure still was compared with conventional still. The total production of the still was increased by 88.66% when a light cotton cloth was used as wick material in the basin along with minimum depth of water. (authors)

  14. Estimated Trans-Lamina Cribrosa Pressure Differences in Low-Teen and High-Teen Intraocular Pressure Normal Tension Glaucoma: The Korean National Health and Nutrition Examination Survey.

    Directory of Open Access Journals (Sweden)

    Si Hyung Lee

    Full Text Available To investigate the association between estimated trans-lamina cribrosa pressure difference (TLCPD and prevalence of normal tension glaucoma (NTG with low-teen and high-teen intraocular pressure (IOP using a population-based study design.A total of 12,743 adults (≥ 40 years of age who participated in the Korean National Health and Nutrition Examination Survey (KNHANES from 2009 to 2012 were included. Using a previously developed formula, cerebrospinal fluid pressure (CSFP in mmHg was estimated as 0.55 × body mass index (kg/m2 + 0.16 × diastolic blood pressure (mmHg-0.18 × age (years-1.91. TLCPD was calculated as IOP-CSFP. The NTG subjects were divided into two groups according to IOP level: low-teen NTG (IOP ≤ 15 mmHg and high-teen NTG (15 mmHg < IOP ≤ 21 mmHg groups. The association between TLCPD and the prevalence of NTG was assessed in the low- and high-teen IOP groups.In the normal population (n = 12,069, the weighted mean estimated CSFP was 11.69 ± 0.04 mmHg and the weighted mean TLCPD 2.31 ± 0.06 mmHg. Significantly higher TLCPD (p < 0.001; 6.48 ± 0.27 mmHg was found in the high-teen NTG compared with the normal group. On the other hand, there was no significant difference in TLCPD between normal and low-teen NTG subjects (p = 0.395; 2.31 ± 0.06 vs. 2.11 ± 0.24 mmHg. Multivariate logistic regression analysis revealed that TLCPD was significantly associated with the prevalence of NTG in the high-teen IOP group (p = 0.006; OR: 1.09; 95% CI: 1.02, 1.15, but not the low-teen IOP group (p = 0.636. Instead, the presence of hypertension was significantly associated with the prevalence of NTG in the low-teen IOP group (p < 0.001; OR: 1.65; 95% CI: 1.26, 2.16.TLCPD was significantly associated with the prevalence of NTG in high-teen IOP subjects, but not low-teen IOP subjects, in whom hypertension may be more closely associated. This study suggests that the underlying mechanisms may differ between low-teen and high-teen NTG patients.

  15. Evaluation of Different Dose-Response Models for High Hydrostatic Pressure Inactivation of Microorganisms

    Directory of Open Access Journals (Sweden)

    Sencer Buzrul

    2017-09-01

    Full Text Available Modeling of microbial inactivation by high hydrostatic pressure (HHP requires a plot of the log microbial count or survival ratio versus time data under a constant pressure and temperature. However, at low pressure and temperature values, very long holding times are needed to obtain measurable inactivation. Since the time has a significant effect on the cost of HHP processing it may be reasonable to fix the time at an appropriate value and quantify the inactivation with respect to pressure. Such a plot is called dose-response curve and it may be more beneficial than the traditional inactivation modeling since short holding times with different pressure values can be selected and used for the modeling of HHP inactivation. For this purpose, 49 dose-response curves (with at least 4 log10 reduction and ≥5 data points including the atmospheric pressure value (P = 0.1 MPa, and with holding time ≤10 min for HHP inactivation of microorganisms obtained from published studies were fitted with four different models, namely the Discrete model, Shoulder model, Fermi equation, and Weibull model, and the pressure value needed for 5 log10 (P5 inactivation was calculated for all the models above. The Shoulder model and Fermi equation produced exactly the same parameter and P5 values, while the Discrete model produced similar or sometimes the exact same parameter values as the Fermi equation. The Weibull model produced the worst fit (had the lowest adjusted determination coefficient (R2adj and highest mean square error (MSE values, while the Fermi equation had the best fit (the highest R2adj and lowest MSE values. Parameters of the models and also P5 values of each model can be useful for the further experimental design of HHP processing and also for the comparison of the pressure resistance of different microorganisms. Further experiments can be done to verify the P5 values at given conditions. The procedure given in this study can also be extended for

  16. Effects of Strength Training Sessions Performed with Different Exercise Orders and Intervals on Blood Pressure and Heart Rate Variability.

    Science.gov (United States)

    Lemos, Sandro; Figueiredo, Tiago; Marques, Silvio; Leite, Thalita; Cardozo, Diogo; Willardson, Jeffrey M; Simão, Roberto

    2018-01-01

    This study compared the effect of a strength training session performed at different exercise orders and rest intervals on blood pressure and heart rate variability (HRV). Fifteen trained men performed different upper body exercise sequences [large to small muscle mass (SEQA) and small to large muscle mass (SEQB)] in randomized order with rest intervals between sets and exercises of 40 or 90 seconds. Fifteen repetition maximum loads were tested to control the training intensity and the total volume load. The results showed, significant reductions for systolic blood pressure (SBP) for all sequences compared to baseline and, post-exercise: SEQA90 at 20, 30, 40, 50 and 60 minutes; SEQA40 and SEQB40 at 20 minutes and SEQB90 at 10, 20, 30, 40, 50 and 60 minutes. For diastolic blood pressure (DBP), significant reductions were found for three sequences compared to baseline and, post-exercise: SEQA90 and SEQA40 at 50 and 60 minutes; SEQB40 at 10, 30 and 60 minutes. For HRV, there were significant differences in frequency domain for all sequences compared to baseline. In conclusion, when performing upper body strength training sessions, it is suggested that 90 second rest intervals between sets and exercises promotes a post-exercise hypotensive response in SBP. The 40 second rest interval between sets and exercises was associated with greater cardiac stress, and might be contraindicated when working with individuals that exhibit symptoms of cardiovascular disease.

  17. Neopuff T-piece resuscitator mask ventilation: Does mask leak vary with different peak inspiratory pressures in a manikin model?

    Science.gov (United States)

    Maheshwari, Rajesh; Tracy, Mark; Hinder, Murray; Wright, Audrey

    2017-08-01

    The aim of this study was to compare mask leak with three different peak inspiratory pressure (PIP) settings during T-piece resuscitator (TPR; Neopuff) mask ventilation on a neonatal manikin model. Participants were neonatal unit staff members. They were instructed to provide mask ventilation with a TPR with three PIP settings (20, 30, 40 cm H 2 O) chosen in a random order. Each episode was for 2 min with 2-min rest period. Flow rate and positive end-expiratory pressure (PEEP) were kept constant. Airway pressure, inspiratory and expiratory tidal volumes, mask leak, respiratory rate and inspiratory time were recorded. Repeated measures analysis of variance was used for statistical analysis. A total of 12 749 inflations delivered by 40 participants were analysed. There were no statistically significant differences (P > 0.05) in the mask leak with the three PIP settings. No statistically significant differences were seen in respiratory rate and inspiratory time with the three PIP settings. There was a significant rise in PEEP as the PIP increased. Failure to achieve the desired PIP was observed especially at the higher settings. In a neonatal manikin model, the mask leak does not vary as a function of the PIP when the flow rate is constant. With a fixed rate and inspiratory time, there seems to be a rise in PEEP with increasing PIP. © 2017 Paediatrics and Child Health Division (The Royal Australasian College of Physicians).

  18. Racial differences in the impact of social support on nocturnal blood pressure.

    Science.gov (United States)

    Cooper, Denise C; Ziegler, Michael G; Nelesen, Richard A; Dimsdale, Joel E

    2009-06-01

    To investigate whether black and white adults benefit similarly from perceived social support in relation to blood pressure (BP) dipping during sleep. The Interpersonal Support Evaluation List (ISEL, 12-item version), which measures the perceived availability of several types of functional social support, was examined for interactive effects with race on dipping of mean arterial pressure (MAP), systolic blood pressure (SBP), and diastolic blood pressure (DBP) derived from 24-hour ambulatory blood pressure monitoring (ABPM). The sample consisted of 156 young to middle-aged adults (61 blacks, 95 whites; mean age = 35.7 years). Mean ISEL scores did not differ between racial groups. Controlling for age, body mass index (BMI), resting BP, and socioeconomic status (SES), the interaction of social support by race yielded associations with nighttime dipping in MAP and DBP (p social support increased, white adults received cardiovascular benefits as suggested by enhanced nocturnal dipping of BP, but black adults accrued risks as evidenced by blunted declines in BP during sleep.

  19. Radiation pressure induced difference-sideband generation beyond linearized description

    Energy Technology Data Exchange (ETDEWEB)

    Xiong, Hao, E-mail: haoxiong1217@gmail.com; Fan, Yu-Wan; Yang, Xiaoxue; Wu, Ying, E-mail: yingwu2@126.com [School of Physics, Huazhong University of Science and Technology, Wuhan 430074 (China)

    2016-08-08

    We investigate radiation-pressure induced generation of the frequency components at the difference-sideband in an optomechanical system, which beyond the conventional linearized description of optomechanical interactions between cavity fields and the mechanical oscillation. We analytically calculate amplitudes of these signals, and identify a simple square-root law for both the upper and lower difference-sideband generation which can describe the dependence of the intensities of these signals on the pump power. Further calculation shows that difference-sideband generation can be greatly enhanced via achieving the matching conditions. The effect of difference-sideband generation, which may have potential application for manipulation of light, is especially suited for on-chip optomechanical devices, where nonlinear optomechanical interaction in the weak coupling regime is within current experimental reach.

  20. Differences in blood pressure by measurement technique in neurocritically ill patients: A technological assessment.

    Science.gov (United States)

    Lele, Abhijit V; Wilson, Daren; Chalise, Prabhakar; Nazzaro, Jules; Krishnamoorthy, Vijay; Vavilala, Monica S

    2018-01-01

    Blood pressure data may vary by measurement technique. We performed a technological assessment of differences in blood pressure measurement between non-invasive blood pressure (NIBP) and invasive arterial blood pressure (ABP) in neurocritically ill patients. After IRB approval, a prospective observational study was performed to study differences in systolic blood pressure (SBP), mean arterial pressure (MAP), and cerebral perfusion pressure (CPP) values measured by NIBP arm, ABP at level of the phlebostatic axis (ABP heart) and ABP at level of the external auditory meatus (ABP brain) at 30 and 45-degree head of bed elevation (HOB) using repeated measure analysis of covariance and correlation coefficients. Overall, 168 patients were studied with median age of 57 ± 15 years, were mostly female (57%), with body mass index ≤30 (66%). Twenty-three percent (n = 39) had indwelling intracranial pressure monitors, and 19.7% (n = 33) received vasoactive agents. ABP heart overestimated ABP brain for SBP (11.5 ± 2.7 mmHg, p ABP heart overestimated NIBP arm for SBP (8 ± 1.5 mmHg, p ABP heart overestimates MAP compared to ABP brain and NIBP arm. Using ABP heart data overestimates CPP and may be responsible for not achieving SBP, MAP or CPP targets aimed at the brain. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. High hydrostatic pressure inactivation of total aerobic bacteria, lactic acid bacteria, yeasts in sour Chinese cabbage.

    Science.gov (United States)

    Li, Lin; Feng, Lun; Yi, Junjie; Hua, Cheng; Chen, Fang; Liao, Xiaojun; Wang, Zhengfu; Hu, Xiaosong

    2010-08-15

    This study investigated the inactivation of total aerobic bacteria (TAB), lactic acid bacteria (LAB), yeasts in sour Chinese cabbage (SCC) treated by high hydrostatic pressure (HHP). The pressure level ranged from 200 to 600 MPa and the treatment time were 10-30 min. All samples were stored at 4, 27 and 37 degrees C for 90 days. The pressure level of 200 MPa had no significant impact on these microorganisms. The counts of TAB were significantly reduced by 2.7-4.0 log(10)CFU/g at 400 MPa and 4.2-4.5 log(10)CFU/g at 600 MPa from 6.2 log(10)CFU/g; the counts of LAB were also reduced by 2.4-4.3 log(10)CFU/g at 400 MPa from 7.0 log(10)CFU/g and LAB was completely inactivated at 600 MPa; the counts of yeasts were reduced by 1.5-2.0 log(10)CFU/g at 400 and 600 MPa from 4.2 log(10)CFU/g. Storage temperatures significantly influenced the microbial proliferation in HHP-treated SCC depending on the pressure levels. The surviving TAB and LAB at 400 MPa equaled initial counts after 15-day storage at 27 and 37 degrees C, whereas they were inhibited at 4 degrees C up to 60 days. The surviving TAB at 600 MPa did not grow. Yeasts at 400 and 600 MPa decreased below detectable level after 2 days at all the three storage temperatures. From the microbial safety point of view, the result indicated that HHP at 600 MPa could be used as an alternative preservation method for SCC. Copyright 2010 Elsevier B.V. All rights reserved.

  2. Analysis on the Spatial Difference of Bacterial Community Structure in Micro-pressure Air-lift Loop Reactor

    Science.gov (United States)

    Wan, L. G.; Lin, Q.; Bian, D. J.; Ren, Q. K.; Xiao, Y. B.; Lu, W. X.

    2018-02-01

    In order to reveal the spatial difference of the bacterial community structure in the Micro-pressure Air-lift Loop Reactor, the activated sludge bacterial at five different representative sites in the reactor were studied by denaturing gradient gel electrophoresis (DGGE). The results of DGGE showed that the difference of environmental conditions (such as substrate concentration, dissolved oxygen and PH, etc.) resulted in different diversity and similarity of microbial flora in different spatial locations. The Shannon-Wiener diversity index of the total bacterial samples from five sludge samples varied from 0.92 to 1.28, the biodiversity index was the smallest at point 5, and the biodiversity index was the highest at point 2. The similarity of the flora between the point 2, 3 and 4 was 80% or more, respectively. The similarity of the flora between the point 5 and the other samples was below 70%, and the similarity of point 2 was only 59.2%. Due to the different contribution of different strains to the removal of pollutants, it can give full play to the synergistic effect of bacterial degradation of pollutants, and further improve the efficiency of sewage treatment.

  3. Differences in perioperative femoral and radial arterial blood pressure in neonates and infants undergoing cardiac surgery requiring cardiopulmonary bypass

    Directory of Open Access Journals (Sweden)

    Hwa Jin Cho

    Full Text Available Abstract Objective: Several reports claim that blood pressure (BP in the radial artery may underestimate the accurate BP in critically ill patients. Here, the authors evaluated differences in mean blood pressure (MBP between the radial and femoral artery during pediatric cardiac surgery to determine the effectiveness of femoral arterial BP monitoring. Method: The medical records of children under 1 year of age who underwent open-heart surgery between 2007 and 2013 were retrospectively reviewed. Radial and femoral BP were measured simultaneously, and the differences between these values were analyzed at various times: after catheter insertion, after the initiation of cardiopulmonary bypass (CPB-on, after aortic cross clamping (ACC, after the release of ACC, after weaning from CPB, at arrival in the intensive care unit (ICU, and every 6 h during the first day in the ICU. Results: A total of 121 patients who underwent open-heart surgery met the inclusion criteria. During the intraoperative period, from the beginning to the end of CPB, radial MBPs were significantly lower than femoral MBPs at each time-point measured (p 60 min, odds ratio: 7.47 was a risk factor for lower radial pressure. However, discrepancies between these two values disappeared after arrival in the ICU. There was no incidence of ischemic complications associated with the catheterization of both arteries. Conclusion: The authors suggest that femoral arterial pressure monitoring can be safely performed, even in neonates, and provides more accurate BP values during CPB-on periods, and immediately after weaning from CPB, especially when CPB time was greater than 60 min.

  4. Bursting tests on pressure vessels with cracks differing in configuration and location

    International Nuclear Information System (INIS)

    Stahlberg, R.

    1978-01-01

    For assessing the safety of nuclear pressure vessels exhibiting cracks, bursting test were carried out on a series of medium-size pressure vessels with and without welded nozzles and exhibiting cracks differing in configuration and location. The linear-elastic approach proved to be sufficiently accurate for straight strain conditions up to the onset of general yielding. Other analytical methods were successfully used to cover the plastic region. (orig.) [de

  5. Comparison of plantar pressure distribution between three different shoes and three common movements in futsal.

    Science.gov (United States)

    Teymouri, Meghdad; Halabchi, Farzin; Mirshahi, Maryam; Mansournia, Mohammad Ali; Mousavi Ahranjani, Ali; Sadeghi, Amir

    2017-01-01

    Analysis of in-shoe pressure distribution during sport-specific movements may provide a clue to improve shoe design and prevent injuries. This study compared the mean and the peak pressures over the whole foot and ten separate areas of the foot, wearing different shoes during specific movements. Nine male adult recreational futsal players performed three trials of three sport-specific movements (shuffle, sprint and penalty kick), while they were wearing three brands of futsal shoes (Adidas, Lotto and Tiger). Plantar pressures on dominant feet were collected using the F-SCAN system. Peak and mean pressures for whole foot and each separate area were extracted. For statistical analysis, the mean differences in outcome variables between different shoes and movements were estimated using random-effects regression model using STATA ver.10. In the average calculation of the three movements, the peak pressure on the whole foot in Adidas shoe was less than Lotto [8.8% (CI95%: 4.1-13.6%)] and Tiger shoes [11.8% (CI95%:7-16.7%)], (P<0.001). Also, the recorded peak pressure on the whole foot in penalty kick was 61.1% (CI95%: 56.3-65.9%) and 57.6% (CI95%: 52.8-62.3%) less than Shuffle and Sprint tests, respectively (P<0.001). Areas with the highest peak pressure during all 3 movements were not different between all shoes. This area was medial forefoot in cases of shuffle and sprint movements and medial heel in case of penalty kick.

  6. Comparison of plantar pressure distribution between three different shoes and three common movements in futsal.

    Directory of Open Access Journals (Sweden)

    Meghdad Teymouri

    Full Text Available Analysis of in-shoe pressure distribution during sport-specific movements may provide a clue to improve shoe design and prevent injuries. This study compared the mean and the peak pressures over the whole foot and ten separate areas of the foot, wearing different shoes during specific movements.Nine male adult recreational futsal players performed three trials of three sport-specific movements (shuffle, sprint and penalty kick, while they were wearing three brands of futsal shoes (Adidas, Lotto and Tiger. Plantar pressures on dominant feet were collected using the F-SCAN system. Peak and mean pressures for whole foot and each separate area were extracted. For statistical analysis, the mean differences in outcome variables between different shoes and movements were estimated using random-effects regression model using STATA ver.10.In the average calculation of the three movements, the peak pressure on the whole foot in Adidas shoe was less than Lotto [8.8% (CI95%: 4.1-13.6%] and Tiger shoes [11.8% (CI95%:7-16.7%], (P<0.001. Also, the recorded peak pressure on the whole foot in penalty kick was 61.1% (CI95%: 56.3-65.9% and 57.6% (CI95%: 52.8-62.3% less than Shuffle and Sprint tests, respectively (P<0.001.Areas with the highest peak pressure during all 3 movements were not different between all shoes. This area was medial forefoot in cases of shuffle and sprint movements and medial heel in case of penalty kick.

  7. Measurement of blood pressure for the diagnosis and management of hypertension in different ethnic groups: one size fits all.

    Science.gov (United States)

    Gill, Paramjit; Haque, M Sayeed; Martin, Una; Mant, Jonathan; Mohammed, Mohammed A; Heer, Gurdip; Johal, Amanpreet; Kaur, Ramandeep; Schwartz, Claire; Wood, Sally; Greenfield, Sheila M; McManus, Richard J

    2017-02-08

    Hypertension is a major risk factor for cardiovascular disease and prevalence varies by ethnic group. The diagnosis and management of blood pressure are informed by guidelines largely based on data from white populations. This study addressed whether accuracy of blood pressure measurement in terms of diagnosis of hypertension varies by ethnicity by comparing two measurement modalities (clinic blood pressure and home monitoring) with a reference standard of ambulatory BP monitoring in three ethnic groups. Cross-sectional population study (June 2010 - December 2012) with patients (40-75 years) of white British, South Asian and African Caribbean background with and without a previous diagnosis of hypertension recruited from 28 primary care practices. The study compared the test performance of clinic BP (using various protocols) and home-monitoring (1 week) with a reference standard of mean daytime ambulatory measurements using a threshold of 140/90 mmHg for clinic and 135/85 mmHg for out of office measurement. A total of 551 participants had complete data of whom 246 were white British, 147 South Asian and 158 African Caribbean. No consistent difference in accuracy of methods of blood pressure measurement was observed between ethnic groups with or without a prior diagnosis of hypertension: for people without hypertension, clinic measurement using three different methodologies had high specificity (75-97%) but variable sensitivity (33-65%) whereas home monitoring had sensitivity of 68-88% and specificity of 64-80%. For people with hypertension, detection of a raised blood pressure using clinic measurements had sensitivities of 34-69% with specificity of 73-92% and home monitoring had sensitivity (81-88%) and specificity (55-65%). For people without hypertension, ABPM remains the choice for diagnosing hypertension compared to the other modes of BP measurement regardless of ethnicity. Differences in accuracy of home monitoring and clinic monitoring (higher sensitivity

  8. Cloudiness and Its Relationship to Saturation Pressure Differences during a Developing East Coast Winter Storm.

    Science.gov (United States)

    Alliss, Randall J.; Raman, Sethu

    1995-11-01

    Cloudiness derived from surface observations and the Geostationary Operational Environmental Satellite VISSR (Visible Infrared Spin Scan Radiometer) Atmospheric Sounder (VAS) are compared with thermodynamic properties derived from upper-air soundings over the Gulf Stream locale during a developing winter storm. The Gulf Stream locale covers the United States mid-Atlantic coastal states, the Gulf Stream, and portions of the Sargasso Sea. Cloudiness is found quite frequently in this region. Cloud-top pressures are derived from VAS using the CO2 slicing technique and a simple threshold procedure. Cloud-base heights and cloud fractions are obtained from National Weather Service hourly reporting stations. The saturation pressure differences, defined as the difference between air parcel pressure and saturation-level pressure (lifted condensation level), are derived from upper-air soundings. Collocated comparisons with VAS and surface observations are also made. Results indicate that cloudiness is observed nearly all of the time during the 6-day period, well above the 8-yr mean. High, middle, and low opaque cloudiness are found approximately equally. Furthermore, of the high- and midlevel cloudiness observed, a considerable amount is determined to be semitransparent to terrestrial radiation. Comparisons of satellite-inferred cloudiness with surface observations indicate that the satellite can complement surface observations of cloud cover, particularly above 700 mb.Surface-observed cloudiness is segregated according to a composite cloud fraction and compared to the mean saturation pressure difference for a 1000 600-mb layer. The analysis suggests that this conserved variable may be a good indicator for estimating cloud fraction. Large negative values of saturation pressure difference correlate highly with clear skies, while those approaching zero correlate with overcast conditions. Scattered and broken cloud fractions are associated with increasing values of the

  9. Numerical study of pressure fluctuations transfer law in different flow rate of turbine mode in a prototype pump turbine

    International Nuclear Information System (INIS)

    Sun, Y K; Zuo, Z G; Liu, S H; Wu, Y L; Liu, J T; Qin, D Q; Wei, X Z

    2013-01-01

    Numerical simulation using SST k-w turbulence model was carried out, to predict pressure fluctuation transfer law in turbine mode. Three operating points with different mass flow rates are simulated. The results of numerical simulation show that, the amplitude and frequency of pressure fluctuations in different positions are very different. The transfer law of amplitude and frequency of pressure fluctuations change with different position and different mass flow rate. Blade passing frequency (BPF) is the first dominant frequency in vaneless space, while component in this frequency got smaller in the upstream and downstream of vaneless space when the mass flow is set. Furthermore triple blade passing frequency (3BPF) component obtained a different transfer law through the whole flow passage. The amplitude and frequency of pressure fluctuations is also different in different circumference position of vaneless space. When the mass flow is different, the distribution of pressure fluctuations in circumference is different. The frequency component of pressure fluctuations in all the positions is different too

  10. Influence of Individual Differences on the Calculation Method for FBG-Type Blood Pressure Sensors.

    Science.gov (United States)

    Koyama, Shouhei; Ishizawa, Hiroaki; Fujimoto, Keisaku; Chino, Shun; Kobayashi, Yuka

    2016-12-28

    In this paper, we propose a blood pressure calculation and associated measurement method that by using a fiber Bragg grating (FBG) sensor. There are several points at which the pulse can be measured on the surface of the human body, and when a FBG sensor located at any of these points, the pulse wave signal can be measured. The measured waveform is similar to the acceleration pulse wave. The pulse wave signal changes depending on several factors, including whether or not the individual is healthy and/or elderly. The measured pulse wave signal can be used to calculate the blood pressure using a calibration curve, which is constructed by a partial least squares (PLS) regression analysis using a reference blood pressure and the pulse wave signal. In this paper, we focus on the influence of individual differences from calculated blood pressure based on each calibration curve. In our study, the calculated blood pressure from both the individual and overall calibration curves were compared, and our results show that the calculated blood pressure based on the overall calibration curve had a lower measurement accuracy than that based on an individual calibration curve. We also found that the influence of the individual differences on the calculated blood pressure when using the FBG sensor method were very low. Therefore, the FBG sensor method that we developed for measuring the blood pressure was found to be suitable for use by many people.

  11. The inter-arm blood pressure difference and peripheral vascular disease: cross-sectional study.

    Science.gov (United States)

    Clark, Christopher E; Campbell, John L; Powell, Roy J; Thompson, John F

    2007-10-01

    A blood pressure (BP) difference between the upper limbs is often encountered in primary care. Knowledge of its prevalence and importance in the accurate measurement of BP is poor, representing a source of error. Current hypertension guidelines do not emphasize this. To establish the prevalence of an inter-arm blood pressure difference (IAD) and explore its association with other indicators of peripheral vascular disease (PVD) in a hypertensive primary care population. This was a cross-sectional study. Primary care, one rural general practice, was the setting of the study. The methods were controlled simultaneous measurement of brachial BPs, ankle-brachial pressure index (ABPI) and tiptoe stress testing in 94 subjects. In all, 18 of 94 [19%, 95% confidence interval (CI) 11-27%] subjects had mean systolic inter-arm difference (sIAD) > or =10 mmHg and seven of 94 (7%, 95% CI 2-12%) had mean diastolic inter-arm difference (dIAD) > or =10 mmHg. Nineteen of 91 (20%, 95% CI 12-28%) had a reduced ABPI pressure drop > or =20%. An IAD and asymptomatic PVD are common in a primary care hypertensive population. Magnitude of the IAD is inversely correlated with ABPI, supporting the hypotheses that IADs are causally linked to PVD, and that IAD is a useful marker for the presence of PVD. Consequently, detection of an IAD should prompt the clinician to screen subjects for other signs of vascular disease and target them for aggressive cardiovascular risk factor modification.

  12. [Measuring the blood pressure in both arms is of little use; longitudinal study into blood pressure differences between both arms and its reproducibility in patients with diabetes mellitus type 2].

    Science.gov (United States)

    Kleefstra, N; Houweling, S T; Meyboom-de Jong, B; Bilo, H J G

    2007-07-07

    To determine the prevalence of inter-arm blood pressure differences > 10 mmHg in patients with diabetes mellitus type 2 (DM2) and to determine whether these differences are consistent over time. Descriptive. In an evaluation study of 169 DM2 patients from 5 general practices in 2003 and 2004, different methods of oscillatory measurement were used to investigate inter-arm blood pressure differences > 10 mmHg systolic or diastolic. These methods were: one measurement in each arm non-simultaneously (method A), one measurement simultaneously (B) and the mean of two simultaneous measurements (C). With method A an inter-arm blood pressure difference was found in 33% of patients. This percentage diminished to 9 with method C. In 44% (n = 7) of the patients in whom method C detected a relevant blood pressure difference, this difference was not found with method A. In 79% of patients the inter-arm blood pressure difference was not reproduced after one year. In daily practice, one non-simultaneous blood pressure measurement in each arm (method A) was of little value for identification of patients with inter-arm blood pressure differences. The reproducibility was poor one year later. Bilateral blood pressure measurement is therefore of little value.

  13. Effect of ultra high pressure homogenization treatment on the bioactive compounds of soya milk.

    Science.gov (United States)

    Toro-Funes, N; Bosch-Fusté, J; Veciana-Nogués, M T; Vidal-Carou, M C

    2014-01-01

    Ultra high pressure homogenization (UHPH) is a useful novel technology to obtain safe and high-quality liquid foods. The effect of UHPH at 200 and 300 MPa in combination with different inlet temperatures (Tin) (55, 65 and 75 °C) on the bioactive compounds of soya milk was studied. Total phytosterols increased with the higher combination of pressure and temperature. The main phytosterol was β-sitosterol, followed by stigmasterol and campesterol. Total tocopherols in UHPH-treated soya milks decreased as the temperature and pressure increased. UHPH treatment also affected the different chemical forms of tocopherols. No biogenic amines were detected in any of the analyzed soya milks. Meanwhile, the polyamines SPD and SPM were found in all soya milks, being stable to the UHPH treatment. Total isoflavones increased with the higher combination of pressure and temperature. No differences in the isoflavone profile were found, with β-glucoside conjugates being the predominant form. Copyright © 2013 Elsevier Ltd. All rights reserved.

  14. The difference in endolymphatic hydrostatic pressure elevation induced by isoproterenol between the ampulla and the cochlea.

    Science.gov (United States)

    Inamoto, Ryuhei; Miyashita, Takenori; Matsubara, Ai; Hoshikawa, Hiroshi; Mori, Nozomu

    2017-06-01

    The purpose of the study was to investigate the difference in the responses of endolymphatic hydrostatic pressure to isoproterenol, β-adrenergic receptor agonist, between pars superior and pars inferior. The hydrostatic pressure of endolymph and perilymph and endolymphatic potential in the ampulla and the cochlea during the intravenous administration of isoproterenol were recorded using a servo-null system in guinea pigs. The hydrostatic pressure of endolymph and perilymph in the ampulla and cochlea was similar in magnitude. Isoproterenol significantly increased hydrostatic pressure of ampullar and cochlear endolymph and perilymph with no change in the ampullar endolymphatic potential and endocochlear potential, respectively. The isoproterenol-induced maximum change of endolymphatic hydrostatic pressure in ampulla was significantly (phydrostatic pressure in the ampulla disappeared like that in the cochlea. Isoproterenol elevates endolymphatic hydrostatic pressure in different manner between the vestibule and the cochlea. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  15. Age, gender, and race/ethnic differences in total body and subregional bone density.

    Science.gov (United States)

    Looker, A C; Melton, L J; Harris, T; Borrud, L; Shepherd, J; McGowan, J

    2009-07-01

    Total body bone density of adults from National Health and Nutrition Examination Survey (NHANES) 1999-2004 differed as expected for some groups (men>women and blacks>whites) but not others (whites>Mexican Americans). Cross-sectional age patterns in bone mineral density (BMD) of older adults differed at skeletal sites that varied by degree of weight-bearing. Total body dual-energy X-ray absorptiometry (DXA) data offer the opportunity to compare bone density of demographic groups across the entire skeleton. The present study uses total body DXA data (Hologic QDR 4500A, Hologic, Bedford MA, USA) from the NHANES 1999-2004 to examine BMD of the total body and selected skeletal subregions in a wide age range of adult men and women from three race/ethnic groups. Total body, lumbar spine, pelvis, right leg, and left arm BMD and lean mass from 13,091 adults aged 20 years and older were used. The subregions were chosen to represent sites with different degrees of weight-bearing. Mean BMD varied in expected ways for some demographic characteristics (men>women and non-Hispanic blacks>non-Hispanic whites) but not others (non-Hispanic whites>Mexican Americans). Differences in age patterns in BMD also emerged for some characteristics (sex) but not others (race/ethnicity). Differences in cross-sectional age patterns in BMD and lean mass by degree of weight-bearing in older adults were observed for the pelvis, leg, and arm. This information may be useful for generating hypotheses about age, race, and sex differences in fracture risk in the population.

  16. Unavoidable Pressure Ulcers: Development and Testing of the Indiana University Health Pressure Ulcer Prevention Inventory.

    Science.gov (United States)

    Pittman, Joyce; Beeson, Terrie; Terry, Colin; Dillon, Jill; Hampton, Charity; Kerley, Denise; Mosier, Judith; Gumiela, Ellen; Tucker, Jessica

    2016-01-01

    Despite prevention strategies, hospital-acquired pressure ulcers (HAPUs) continue to occur in the acute care setting. The purpose of this study was to develop an operational definition of and an instrument for identifying avoidable/unavoidable HAPUs in the acute care setting. The Indiana University Health Pressure Ulcer Prevention Inventory (PUPI) was developed and psychometric testing was performed. A retrospective pilot study of 31 adult hospitalized patients with an HAPU was conducted using the PUPI. Overall content validity index of 0.99 and individual item content validity index scores (0.9-1.0) demonstrated excellent content validity. Acceptable PUPI criterion validity was demonstrated with no statistically significant differences between wound specialists' and other panel experts' scoring. Construct validity findings were acceptable with no statistically significant differences among avoidable or unavoidable HAPU patients and their Braden Scale total scores. Interrater reliability was acceptable with perfect agreement on the total PUPI score between raters (κ = 1.0; P = .025). Raters were in total agreement 93% (242/260) of the time on all 12 individual PUPI items. No risk factors were found to be significantly associated with unavoidable HAPUs. An operational definition of and an instrument for identifying avoidable/unavoidable HAPUs in the acute care setting were developed and tested. The instrument provides an objective and structured method for identifying avoidable/unavoidable HAPUs. The PUPI provides an additional method that could be used in root-cause analyses and when reporting adverse pressure ulcer events.

  17. Differences in Activation Area Within Brodmann Area 2 Caused by Pressure Stimuli on Fingers and Joints

    Science.gov (United States)

    Choi, Mi-Hyun; Kim, Hyung-Sik; Baek, Ji-Hye; Lee, Jung-Chul; Park, Sung-Jun; Jeong, Ul-Ho; Gim, Seon-Young; Kim, Sung-Phil; Lim, Dae-Woon; Chung, Soon-Cheol

    2015-01-01

    Abstract In this study, a constant pressure stimulus was applied on the 3 joints (first [p1], second [p2], and third [p3] joints) of 4 fingers (index, middle, ring, and little fingers), and the activation areas within Brodmann area 2 (BA 2) were compared for these different fingers and joints by using functional magnetic resonance imaging. Eight healthy male college students (25.4 ± 1.32 years) participated in the study. Each session was composed of 3 blocks, and each block was composed of a Control phase (30 seconds) and a Pressure phase (30 seconds). No pressure stimulus was applied in the Control phase, during which the subjects would simply lay comfortably with their eyes closed. In the Pressure phase, a pressure stimulus was applied onto one of the joints of the selected finger. For each finger and joint, BA 2 areas activated by the pressure stimulus were extracted by the region of interest method. There was a significant difference in the activation areas for the different fingers (P = .042) as well as for the different joints (P = .050). The activation area decreased in the order of the little, index, and middle fingers, as well as in the order of p1, p3, and p2. PMID:26402840

  18. Effects of different components of Mao Dongqing's total flavonoids and total saponins on transient ischemic attack (TIA) model of rats.

    Science.gov (United States)

    Miao, Ming-San; Peng, Meng-Fan; Ma, Rui-Juan; Bai, Ming; Liu, Bao-Song

    2018-03-01

    Objective: To study the effects of the different components of the total flavonoids and total saponins from Mao Dongqing's active site on the rats of TIA model, determine the optimal reactive components ratio of Mao Dongqing on the rats of TIA. Methods: TIA rat model was induced by tail vein injection of tert butyl alcohol, the blank group was injected with the same amount of physiological saline, then behavioral score wasevaluated. Determination the level of glutamic acid in serum, the activity of Na+-K+-ATP enzyme, CA ++ -ATP enzyme and Mg ++ -ATP enzyme in Brain tissue, observe the changes of hippocampus in brain tissue, the comprehensive weight method was used to evaluate the efficacy of each component finally. Results: The contents of total flavonoids and total saponins in the active part of Mao Dongqing can significantly improve the pathological changes of brain tissue in rats, improve the activity of Na + -K + -ATP enzyme, Ca ++ -ATP enzyme and Mg ++ -ATP enzyme in the brain of rats, and reduce the level of glutamic acid in serum. The most significant of the contents was the ratio of 10:6. The different proportions of total flavonoids and total saponins in the active part of Mao Dongqing all has a better effect on the rats with TIA, and the ratio of 10:6 is the best active component for preventing and controlling TIA.

  19. Selective Pressures Explain Differences in Flower Color among Gentiana lutea Populations.

    Science.gov (United States)

    Sobral, Mar; Veiga, Tania; Domínguez, Paula; Guitián, Javier A; Guitián, Pablo; Guitián, José M

    2015-01-01

    Flower color variation among plant populations might reflect adaptation to local conditions such as the interacting animal community. In the northwest Iberian Peninsula, flower color of Gentiana lutea varies longitudinally among populations, ranging from orange to yellow. We explored whether flower color is locally adapted and the role of pollinators and seed predators as agents of selection by analyzing the influence of flower color on (i) pollinator visitation rate and (ii) escape from seed predation and (iii) by testing whether differences in pollinator communities correlate with flower color variation across populations. Finally, (iv) we investigated whether variation in selective pressures explains flower color variation among 12 G. lutea populations. Flower color influenced pollinator visits and differences in flower color among populations were related to variation in pollinator communities. Selective pressures on flower color vary among populations and explain part of flower color differences among populations of G. lutea. We conclude that flower color in G. lutea is locally adapted and that pollinators play a role in this adaptation.

  20. Selective Pressures Explain Differences in Flower Color among Gentiana lutea Populations.

    Directory of Open Access Journals (Sweden)

    Mar Sobral

    Full Text Available Flower color variation among plant populations might reflect adaptation to local conditions such as the interacting animal community. In the northwest Iberian Peninsula, flower color of Gentiana lutea varies longitudinally among populations, ranging from orange to yellow. We explored whether flower color is locally adapted and the role of pollinators and seed predators as agents of selection by analyzing the influence of flower color on (i pollinator visitation rate and (ii escape from seed predation and (iii by testing whether differences in pollinator communities correlate with flower color variation across populations. Finally, (iv we investigated whether variation in selective pressures explains flower color variation among 12 G. lutea populations. Flower color influenced pollinator visits and differences in flower color among populations were related to variation in pollinator communities. Selective pressures on flower color vary among populations and explain part of flower color differences among populations of G. lutea. We conclude that flower color in G. lutea is locally adapted and that pollinators play a role in this adaptation.

  1. EFFECT OF DIFFERENT COMPACTION PRESSURE AND DIFFERENT SINTERING ROUTE ON K0.5NA0.5NBO₃ PHYSICAL AND DIELECTRIC PROPERTIES

    Directory of Open Access Journals (Sweden)

    Nor Fatin Khairah Bahanurddin

    2016-07-01

    Full Text Available Alkaline niobate known as K0.5Na0.5NbO3 (KNN, a lead-free piezoelectric ceramic was synthesized via a solid state reaction method. The samples were compacted at different pressures (100, 200, 300 and 400 MPa and sintered using two different techniques (conventional furnace and hot isostatic pressing (HIP. The effect of compaction pressure and sintering technique on physical and dielectric properties was studied. The optimum compaction pressure (300 MPa and sintering via HIP (at 1080 °C for 30 min increased the density and grain size ( range 30 - 300 nm and improved its dielectric properties. Therefore, the combination of suitable compaction pressure and sintering technique has produced larger grain size and higher density of KNN which resulted in outstanding dielectric properties. At room temperature, excellent values of ε r (5517.35 and tan δ (0.954, recorded at 1 MHz were measured for the KNN300HIP sample with highest density (4.4885 g/cm³.

  2. Differences and effects of medium and large adult cuffs on blood pressure readings in individuals with muscular arms.

    Science.gov (United States)

    Fonseca-Reyes, Salvador; Fajardo-Flores, Ismael; Montes-Casillas, Mayra; Forsyth-Macquarrie, Avril

    2009-08-01

    This study analyzed systolic and diastolic blood pressure (SBP and DBP) reading differences in individuals with muscular arms, using medium and large adult cuffs. Resting blood pressures (BPs) were measured in bodybuilders competing at the Mexican National Bodybuilding and Fitness Championship. The means of two bilateral simultaneous arm BP measurements were obtained using two different cuff sizes, 12 cm (medium adult) and 16 cm (large adult). A total of 193 bodybuilders completed the measurements. With an arm circumference greater than 33 cm, the SBP and DBP average taken with the medium adult cuff was higher than that obtained with the large adult cuff, 8.2+/-10.6 and 1.6+/-7.4 mmHg, respectively; however, a significant difference was observed only with the SBP. With the medium adult cuff, 48 of 144 individuals showed SBP at least 140 mmHg, whereas with the large adult cuff there were only 17 of 144 individuals. In those participants with an arm circumference less than 33 cm, the BP was nonsignificantly lower with the large cuff, -4.24+/-9.2 and -2.24+/-5.4 mmHg for the SBP and DBP, respectively. Incorrect cuffing of a muscular arm leads to significant errors in the measurement of SBP and DBP, similar to that observed in miscuffing of nonmuscular arms.

  3. Low-pressure glow discharges with oscillating electrons in different electrode systems

    International Nuclear Information System (INIS)

    Bersenev, V.V.; Gavriolv, N.V.; Nikulin, S.P.

    1995-01-01

    One of the main applications of low - pressure glow discharges is the development on their basis of charged - particle beam sources. The use of glow discharges with oscillating electrons, which can operate stably in the voltage and pressure range to the left of the left branch of Pashen's curve, shows promise, because the decrease in critical pressure p 0 , below which the discharge operation becomes impossible, in the discharge system of a source promotes an increase in the electrical strength of its accelerating system. This, in its turn, makes possible the expansion of the operation range of accelerating voltages. This experimental investigation of glow discharges in such well - known systems with oscillating electrons, as Hollow Cathode (HC), Penning's System (PS) and Inverse Magnetron (IM), is aimed at revealing the system operating at the lowest pressure. Besides, both common features and peculiarities of discharge operation in these systems are discussed. Though there is an extensive amount of published information covering all the specified discharges, the carrying out of such investigation is justified, since a comparative analysis of results obtained by different authors is hampered by various conditions of their experiments

  4. Numerical study of pressure fluctuations in different guide vanes' opening angle in pump mode of a pump turbine

    International Nuclear Information System (INIS)

    Sun, Y K; Zuo, Z G; Liu, S H; Wu, Y L; Liu, J T

    2012-01-01

    A numerical model based on a pumped storage power station was built to develop the numerical simulation, to analyze the pressure fluctuations in a pump turbine in different guide vanes' opening angle. The different guide vanes' opening angles were simulated using the SST k-ω turbulence model and SIMPLEC Pressure-Velocity coupling scheme. The pressure sensor were placed in mainly three positions, they are: bottom ring between runner and the wicket gates, downstream and left side in the draft tube cone below the runner. All the peak to peak values of pressure fluctuation meet signal probability of 97%. The frequency is gained by Fast Fourier Transform. The pressure fluctuations in different positions of the model in pump condition were showed when the guide vanes' opening angels were different. The simulation results confirmed the results gained in model tests. The results show that pressure fluctuations in design opening angle were much lower than those in off design opening angle. The main source of pressure fluctuations between runner and guide vanes is rotor stator interaction. While a lower frequency is the main frequency of the pressure fluctuation in draft tube.

  5. Effect of different body postures on the pressures generated during an L-1 maneuver.

    Science.gov (United States)

    Williams, C A; Lind, A R; Wiley, R L; Douglas, J E; Miller, G

    1988-10-01

    Changes in blood pressure, intrathoracic pressure, heart rate and the electromyographic activity of various muscle groups were determined while nine male subjects performed 15-s L-1 straining maneuvers at four spine-to-thigh angles (70, 84, 94, and 105 degrees) and two seatback angles (30 and 60 degrees). There was no significant difference between the changes in these variables due to the different body positions. At the onset of the L-1, arterial pressure immediately increased to 195 +/- 5 mm Hg, but fell progressively during the next 5 s to 160 +/- 5 mm Hg. It remained constant during the next 5 s of the maneuver and then recovered to 180 +/- mm Hg during the last 5 s of the maneuver. Esophageal pressure followed essentially the same pattern of response, but heart rate progressively increased during the entire L-1. No one muscle group was utilized more than another. Inflation of an anti-G suit to 4 PSI had no effect on the variables measured. Generation of high arterial pressures during L-1 maneuvers is transitory and not affected either positively or negatively by altering subject body position.

  6. Skin interface pressure on the NATO litter.

    Science.gov (United States)

    Bridges, Elizabeth J; Schmelz, Joseph O; Mazer, Stephen

    2003-04-01

    The NATO litter serves as a transport device and hospital bed during all types of operations. Little is known about the skin interface pressure on this litter. The purpose of this study was to determine whether various types of padding on the litter and body position affect the peak skin interface pressure and the total body area exposed to interface pressures above 30 mm Hg at different body areas. Thirty-two subjects participated. A repeated measures design was used. The surface effect was statistically significant for all peak pressure and surface area analyses (repeated-measures analysis of variance, p patients if feasible. Preventive measures (turning, elevating the heels) are still required.

  7. Different Selection Pressures Give Rise to Distinct Ethnic Phenomena

    Science.gov (United States)

    Moya, Cristina; Boyd, Robert

    2015-01-01

    Many accounts of ethnic phenomena imply that processes such as stereotyping, essentialism, ethnocentrism, and intergroup hostility stem from a unitary adaptation for reasoning about groups. This is partly justified by the phenomena’s co-occurrence in correlational studies. Here we argue that these behaviors are better modeled as functionally independent adaptations that arose in response to different selection pressures throughout human evolution. As such, different mechanisms may be triggered by different group boundaries within a single society. We illustrate this functionalist framework using ethnographic work from the Quechua-Aymara language boundary in the Peruvian Altiplano. We show that different group boundaries motivate different ethnic phenomena. For example, people have strong stereotypes about socioeconomic categories, which are not cooperative units, whereas they hold fewer stereotypes about communities, which are the primary focus of cooperative activity. We also show that, despite the cross-cultural importance of ethnolinguistic boundaries, the Quechua-Aymara linguistic distinction does not strongly motivate any of these intergroup processes. PMID:25731969

  8. Estimation of vapour pressure and partial pressure of subliming ...

    Indian Academy of Sciences (India)

    Administrator

    conditions of (total) pressure by using thermogravimetry under those conditions. Further, from the partial pressure P, it is possible to determine the number of moles of material in the vapour phase using the ideal gas equation, PV = nRT, where P is the partial pressure, V the volume, n number of moles (of the vapour), R the ...

  9. Emergence of ethnic differences in blood pressure in adolescence: the determinants of adolescent social well-being and health study.

    Science.gov (United States)

    Harding, Seeromanie; Whitrow, Melissa; Lenguerrand, Erik; Maynard, Maria; Teyhan, Alison; Cruickshank, J Kennedy; Der, Geoff

    2010-04-01

    The cause of ethnic differences in cardiovascular disease remains a scientific challenge. Blood pressure tracks from late childhood to adulthood. We examined ethnic differences in changes in blood pressure between early and late adolescence in the United Kingdom. Longitudinal measures of blood pressure, height, weight, leg length, smoking, and socioeconomic circumstances were obtained from London, United Kingdom, schoolchildren of White British (n=692), Black Caribbean (n=670), Black African (n=772), Indian (n=384), and Pakistani and Bangladeshi (n=402) ethnicity at 11 to 13 years and 14 to 16 years. Predicted age- and ethnic-specific means of blood pressure, adjusted for anthropometry and social exposures, were derived using mixed models. Among boys, systolic blood pressure did not differ by ethnicity at 12 years, but the greater increase among Black Africans than Whites led to higher systolic blood pressure at 16 years (+2.9 mm Hg). Among girls, ethnic differences in mean systolic blood pressure were not significant at any age, but while systolic blood pressure hardly changed with age among White girls, it increased among Black Caribbeans and Black Africans. Ethnic differences in diastolic blood pressure were more marked than those for systolic blood pressure. Body mass index, height, and leg length were independent predictors of blood pressure, with few ethnic-specific effects. Socioeconomic disadvantage had a disproportionate effect on blood pressure for girls in minority groups. The findings suggest that ethnic divergences in blood pressure begin in adolescence and are particularly striking for boys. They signal the need for early prevention of adverse cardiovascular disease risks in later life.

  10. Structural and electronic properties of high pressure phases of lead chalcogenides

    Science.gov (United States)

    Petersen, John; Scolfaro, Luisa; Myers, Thomas

    2012-10-01

    Lead chalcogenides, most notably PbTe and PbSe, have become an active area of research due to their thermoelectric properties. The high figure of merit (ZT) of these materials has brought much attention to them, due to their ability to convert waste heat into electricity. Variation in synthesis conditions gives rise to a need for analysis of structural and thermoelectric properties of these materials at different pressures. In addition to the NaCl structure at ambient conditions, lead chalcogenides have a dynamic orthorhombic (Pnma) intermediate phase and a higher pressure yet stable CsCl phase. By altering the lattice constant, we simulate the application of external pressure; this has notable effects on ground state total energy, band gap, and structural phase. Using the General Gradient Approximation (GGA) in Density Functional Theory (DFT), we calculate the phase transition pressures by finding the differences in enthalpy from total energy calculations. For each phase, elastic constants, bulk modulus, shear modulus, Young's modulus, and hardness are calculated, using two different approaches. In addition to structural properties, we analyze the band structure and density of states at varying pressures, paying special note to thermoelectric implications.

  11. Sensing performances of ZnO nanostructures grown under different oxygen pressures to hydrogen

    International Nuclear Information System (INIS)

    Chu, Jin; Peng, Xiaoyan; Wang, Zhenbo; Feng, Peter

    2012-01-01

    Graphical abstract: Display Omitted Highlights: ► Surface morphology depends on the oxygen pressure. ► Structural degradation was observed for the ZnO samples when oxygen pressure was overhigh. ► The sensitivity of the ZnO-based sensors increase with grown oxygen pressure. -- Abstract: For extensive use in an industrialized process of individual ZnO nanostructures applied in gas sensors, a simple, inexpensive, and safe synthesis process is required. Here, nanostructured ZnO films were grown by a pulsed laser deposition technique under different oxygen pressures. Scanning electron microscopy images show nanopores, nanotips, and nanoparticles are obtained and energy dispersive X-ray spectroscopy data indicate oxygen concentration of the synthesized samples increases monotonously with oxygen pressure. The sensor based on ZnO with high oxygen concentration has high sensitivity, rapid response (9 s) and recovery (80 s) behavior to 500 ppm hydrogen below 150 °C. Experimental data indicate that high oxygen concentration effectively improves the sensing properties of nanostructured ZnO.

  12. The cost of pressure ulcers in the UK.

    Science.gov (United States)

    Bennett, Gerry; Dealey, Carol; Posnett, John

    2004-05-01

    To estimate the annual cost of treating pressure ulcers in the UK. Costs were derived from a bottom-up methodology, based on the daily resources required to deliver protocols of care reflecting good clinical practice. Health and social care system in the UK. Patients developing a pressure ulcer. A bottom-up costing approach is used to estimate treatment cost per episode of care and per patient for ulcers of different grades and level of complications. Also, total treatment cost to the health and social care system in the UK. The cost of treating a pressure ulcer varies from pound 1,064 (Grade 1) to pound 10,551 (Grade 4). Costs increase with ulcer grade because the time to heal is longer and because the incidence of complications is higher in more severe cases. The total cost in the UK is pound 1.4- pound 2.1 billion annually (4% of total NHS expenditure). Most of this cost is nurse time. Pressure ulcers represent a very significant cost burden in the UK. Without concerted effort this cost is likely to increase in the future as the population ages. To the extent that pressure ulcers are avoidable, pressure damage may be indicative of clinical negligence and there is evidence that litigation could soon become a significant threat to healthcare providers in the UK, as it is in the USA.

  13. FCT (functional computed tomography) evaluation of the lung volumes at different PEEP (positive-end expiratory pressure) ventilation pattern, in mechanical ventilated patients

    International Nuclear Information System (INIS)

    Papi, M.G.; Di Segni, R.; Mazzetti, G.; Staffa, F.; Conforto, F.; Calimici, R.; Salvi, A.; Matteucci, G.

    2007-01-01

    Purpose To evaluate with FCT (functional computed tomography) total lung volume and fractional lung volumes at different PEEP (positive end expiratory pressure) values in acute mechanically ventilated patients. Methods Nine ICU (intensive care unity) patients (1 lung pneumonia, 2 polytrauma, 2 sepsis, 3 brain surgery, 1 pulmonary embolism); mean age 48 ± 15 years, 6 male, 3 female; GE 16 MDCT scan was performed with acquisition from apex to diaphragma in seven seca at different PEEP values. Raw CT data were analysed by an advantage workstation to obtain volume density masks and histograms of both lungs and each lung and these density ranges were applied: - 1000 - 950 hyper-ventilated lung, -900 - 650 well aerated lung, -950 - 500 all aerated lung, -500 + 200 lung tissue. Total and fractional lung volumes, Hounsfield unit (HU) were calculated and compared at different PEEP values (0, 5, 10, 15 cm H 2 O). In four patients lung volumes were compared between the more and the less involved lung at increased PEEP. Statistic analysis: comparison means-medians tests. Results Data calculated at five PEEP showed unexpected decrease of total lung volume and increase of lung density (HU); proportionally no significant improvement of oxigenation. (orig.)

  14. FCT (functional computed tomography) evaluation of the lung volumes at different PEEP (positive-end expiratory pressure) ventilation pattern, in mechanical ventilated patients

    Energy Technology Data Exchange (ETDEWEB)

    Papi, M.G.; Di Segni, R.; Mazzetti, G.; Staffa, F. [Dept. of Radiology, S. Giovanni HS, Rome (Italy); Conforto, F.; Calimici, R.; Salvi, A. [Dept. of Anesthesiology, S. Giovanni HS, Rome (Italy); Matteucci, G. [Dept. of Pneumology, S. Giovanni HS, Rome (Italy)

    2007-06-15

    Purpose To evaluate with FCT (functional computed tomography) total lung volume and fractional lung volumes at different PEEP (positive end expiratory pressure) values in acute mechanically ventilated patients. Methods Nine ICU (intensive care unity) patients (1 lung pneumonia, 2 polytrauma, 2 sepsis, 3 brain surgery, 1 pulmonary embolism); mean age 48 {+-} 15 years, 6 male, 3 female; GE 16 MDCT scan was performed with acquisition from apex to diaphragma in seven seca at different PEEP values. Raw CT data were analysed by an advantage workstation to obtain volume density masks and histograms of both lungs and each lung and these density ranges were applied: - 1000 - 950 = hyper-ventilated lung, -900 - 650 well aerated lung, -950 - 500 all aerated lung, -500 + 200 lung tissue. Total and fractional lung volumes, Hounsfield unit (HU) were calculated and compared at different PEEP values (0, 5, 10, 15 cm H{sub 2}O). In four patients lung volumes were compared between the more and the less involved lung at increased PEEP. Statistic analysis: comparison means-medians tests. Results Data calculated at five PEEP showed unexpected decrease of total lung volume and increase of lung density (HU); proportionally no significant improvement of oxigenation. (orig.)

  15. The Difference in Translaminar Pressure Gradient and Neuroretinal Rim Area in Glaucoma and Healthy Subjects

    Directory of Open Access Journals (Sweden)

    Lina Siaudvytyte

    2014-01-01

    Full Text Available Purpose. To assess differences in translaminar pressure gradient (TPG and neuroretinal rim area (NRA in patients with normal tension glaucoma (NTG, high tension glaucoma (HTG, and healthy controls. Methods. 27 patients with NTG, HTG, and healthy controls were included in the prospective pilot study (each group consisted of 9 patients. Intraocular pressure (IOP, intracranial pressure (ICP, and confocal laser scanning tomography were assessed. TPG was calculated as the difference of IOP minus ICP. ICP was measured using noninvasive two-depth transcranial Doppler device. The level of significance P 0.05. The difference between TPG for healthy (5.4(7.7 mmHg and glaucomatous eyes (NTG 6.3(3.1 mmHg, HTG 15.7(7.7 mmHg was statistically significant (P < 0.001. Higher TPG was correlated with decreased NRA (r = −0.83; P = 0.01 in the NTG group. Conclusion. Translaminar pressure gradient was higher in glaucoma patients. Reduction of NRA was related to higher TPG in NTG patients. Further prospective studies are warranted to investigate the involvement of TPG in glaucoma management.

  16. Positron annihilation spectroscopy studies of bronze exposed to sandblasting at different pressure

    Science.gov (United States)

    Kurdyumov, S.; Siemek, K.; Horodek, P.

    2017-11-01

    An application of Doppler broadening of annihilation line spectroscopy to samples of beryllium bronze DIN-CuBe2 exposed to sandblasting is presented in performed studies. It is familiar that sandblasting introduces open-volume defects. Samples were sandblasted under different pressure for 1 minute using 110 μm particles of Al2O3. For a non-defected sample the constant value of S-parameter was detected. In the cases of sandblasted samples, S-parameter decreased when the depth enhanced. In our studies the thicknesses of defected zones were determined (it was c.a. 30 μm for a sample blasted under pressure of 1 bar and 110 μm - for 5 bar), and it was also observed that if sandblasting pressure is higher the defected zone is larger.

  17. The influence of slightly different main circulation pumps on PWR coolant pressure pulsations

    International Nuclear Information System (INIS)

    Dach, K.; Pecinka, L.

    1989-01-01

    Pressure distribution along the core barrel circumference caused by the simultaneous operation of six main circulating pumps with slightly different revolutions obtained as a result of measurement in operated NPP is determined on the basis of the well-known Penzes method based on the solving of the wave equation with source term using the expansion into the infinite series of eigenfunctions. Results of calculations can be summarized as follows: the pressure distribution and the resulting force acting on the core barrel has a random character. The same is valid for core barrel vibrations and mainly for the joint between core barrel and pressure vessel. (orig.)

  18. Propagation of Radiosonde Pressure Sensor Errors to Ozonesonde Measurements

    Science.gov (United States)

    Stauffer, R. M.; Morris, G.A.; Thompson, A. M.; Joseph, E.; Coetzee, G. J. R.; Nalli, N. R.

    2014-01-01

    Several previous studies highlight pressure (or equivalently, pressure altitude) discrepancies between the radiosonde pressure sensor and that derived from a GPS flown with the radiosonde. The offsets vary during the ascent both in absolute and percent pressure differences. To investigate this problem further, a total of 731 radiosonde-ozonesonde launches from the Southern Hemisphere subtropics to Northern mid-latitudes are considered, with launches between 2005 - 2013 from both longer-term and campaign-based intensive stations. Five series of radiosondes from two manufacturers (International Met Systems: iMet, iMet-P, iMet-S, and Vaisala: RS80-15N and RS92-SGP) are analyzed to determine the magnitude of the pressure offset. Additionally, electrochemical concentration cell (ECC) ozonesondes from three manufacturers (Science Pump Corporation; SPC and ENSCI-Droplet Measurement Technologies; DMT) are analyzed to quantify the effects these offsets have on the calculation of ECC ozone (O3) mixing ratio profiles (O3MR) from the ozonesonde-measured partial pressure. Approximately half of all offsets are 0.6 hPa in the free troposphere, with nearly a third 1.0 hPa at 26 km, where the 1.0 hPa error represents 5 persent of the total atmospheric pressure. Pressure offsets have negligible effects on O3MR below 20 km (96 percent of launches lie within 5 percent O3MR error at 20 km). Ozone mixing ratio errors above 10 hPa (30 km), can approach greater than 10 percent ( 25 percent of launches that reach 30 km exceed this threshold). These errors cause disagreement between the integrated ozonesonde-only column O3 from the GPS and radiosonde pressure profile by an average of +6.5 DU. Comparisons of total column O3 between the GPS and radiosonde pressure profiles yield average differences of +1.1 DU when the O3 is integrated to burst with addition of the McPeters and Labow (2012) above-burst O3 column climatology. Total column differences are reduced to an average of -0.5 DU when

  19. Microbial quality of soil from the Pampa biome in response to different grazing pressures

    Directory of Open Access Journals (Sweden)

    Rafael S. Vargas

    2015-06-01

    Full Text Available The aim of this study was to evaluate the impact of different grazing pressures on the activity and diversity of soil bacteria. We performed a long-term experiment in Eldorado do Sul, southern Brazil, that assessed three levels of grazing pressure: high pressure (HP, with 4% herbage allowance (HA, moderate pressure (MP, with 12% HA, and low pressure (LP, with 16% HA. Two reference areas were also assessed, one of never-grazed native vegetation (NG and another of regenerated vegetation after two years of grazing (RG. Soil samples were evaluated for microbial biomass and enzymatic (β-glucosidase, arylsulfatase and urease activities. The structure of the bacterial community and the population of diazotrophic bacteria were evaluated by RFLP of the 16S rRNA and nifH genes, respectively. The diversity of diazotrophic bacteria was assessed by partial sequencing of the 16S rDNA gene. The presence of grazing animals increased soil microbial biomass in MP and HP. The structures of the bacterial community and the populations of diazotrophic bacteria were altered by the different grazing managements, with a greater diversity of diazotrophic bacteria in the LP treatment. Based on the characteristics evaluated, the MP treatment was the most appropriate for animal production and conservation of the Pampa biome.

  20. A Pilot Study: Comparison of Arm Versus Ankle Noninvasive Blood Pressure Measurement at 2 Different Levels of Backrest Elevation.

    Science.gov (United States)

    Henley, Nicole; Quatrara, Beth D; Conaway, Mark

    2015-01-01

    Standard practice for obtaining noninvasive blood pressure includes arm blood pressure (BP) cuff placement at the level of the heart; however, some critical care patients cannot have BPs taken in their arm because of various conditions, and ankle BPs are frequently used as substitutes. The aim of this study was to determine if there was a significant variation between upper arm and ankle BP measurements at different backrest elevations with consideration of peripheral edema factors. After institutional review board approval was obtained, a pilot study was implemented to evaluate noninvasive BP measurements of the arm and ankle with backrest elevation at 0° and 30° in a population of medical intensive care unit patients. Participants served as their own controls and were randomly assigned to left- versus right-side BP readings. Data were also collected on presence of arm versus ankle edema. A total of 30 participants enrolled in the study and provided 120 BP measurements. Blood pressure readings were analyzed in terms of diastolic and systolic findings as well as backrest elevations and edema presence. Thirteen participants presented with either arm or ankle edema. There was a statistical difference between the systolic arm and ankle BP measurements in the 0° (P = .008) and 30° (P arm and ankle diastolic BP is greater for participants without ankle edema (P = .038, r = 0.54) than for participants with ankle edema (P = .650, r = 0.14), but it is not statistically significant (P = .47). Even though ankle BPs are often substituted for arm BPs when the arm is unable to be used, ankle BPs and arm BPs are not interchangeable. Adjustments in backrest elevation and considerations of edema do not normalize the differences. Blood pressures obtained from the ankle are significantly greater than those obtained from the arm. This information needs to be considered when arms are not available and legs are used as surrogates for the upper arm.

  1. Hemodynamic differences between continual positive and two types of negative pressure ventilation.

    Science.gov (United States)

    Lockhat, D; Langleben, D; Zidulka, A

    1992-09-01

    In seven anesthetized dogs, ventilated with matching lung volumes, tidal volumes, and respiratory rates, we compared the effects on cardiac output (CO), arterial venous oxygen saturation difference (SaO2 - SVO2), and femoral and inferior vena cava pressure (1) intermittent positive pressure ventilation with positive end-expiratory pressure (CPPV); (2) iron-lung ventilation with negative end-expiratory pressure (ILV-NEEP); (3) grid and wrap ventilation with NEEP applied to the thorax and upper abdomen (G&W-NEEP). The values of CO and SaO2 - SVO2 with ILV-NEEP were similar to those with CPPV. However, with G&W-NEEP as compared with ILV-NEEP, mean CO was greater (2.9 versus 2.6 L/min, p = 0.02) and mean (SaO2 - SVO2) was lower (26.6% versus 28.3%, p = NS). Mean PFEM-IVC was higher with G&W-NEEP than with the other types of ventilation. We conclude that (1) ILV-NEEP is hemodynamically equivalent to CPPV and (2) G&W-NEEP has less adverse hemodynamic consequences. has less adverse hemodynamic consequences.

  2. THE HABITABLE ZONE OF EARTH-LIKE PLANETS WITH DIFFERENT LEVELS OF ATMOSPHERIC PRESSURE

    Energy Technology Data Exchange (ETDEWEB)

    Vladilo, Giovanni; Murante, Giuseppe; Silva, Laura [INAF-Trieste Astronomical Observatory, Trieste (Italy); Provenzale, Antonello [Institute of Atmospheric Sciences and Climate-CNR, Torino (Italy); Ferri, Gaia; Ragazzini, Gregorio, E-mail: vladilo@oats.inaf.it [Department of Physics, University of Trieste, Trieste (Italy)

    2013-04-10

    As a contribution to the study of the habitability of extrasolar planets, we implemented a one-dimensional energy balance model (EBM), the simplest seasonal model of planetary climate, with new prescriptions for most physical quantities. Here we apply our EBM to investigate the surface habitability of planets with an Earth-like atmospheric composition but different levels of surface pressure. The habitability, defined as the mean fraction of the planet's surface on which liquid water could exist, is estimated from the pressure-dependent liquid water temperature range, taking into account seasonal and latitudinal variations of surface temperature. By running several thousands of EBM simulations we generated a map of the habitable zone (HZ) in the plane of the orbital semi-major axis, a, and surface pressure, p, for planets in circular orbits around a Sun-like star. As pressure increases, the HZ becomes broader, with an increase of 0.25 AU in its radial extent from p = 1/3 to 3 bar. At low pressure, the habitability is low and varies with a; at high pressure, the habitability is high and relatively constant inside the HZ. We interpret these results in terms of the pressure dependence of the greenhouse effect, the efficiency of horizontal heat transport, and the extent of the liquid water temperature range. Within the limits discussed in the paper, the results can be extended to planets in eccentric orbits around non-solar-type stars. The main characteristics of the pressure-dependent HZ are modestly affected by variations of planetary properties, particularly at high pressure.

  3. THE HABITABLE ZONE OF EARTH-LIKE PLANETS WITH DIFFERENT LEVELS OF ATMOSPHERIC PRESSURE

    International Nuclear Information System (INIS)

    Vladilo, Giovanni; Murante, Giuseppe; Silva, Laura; Provenzale, Antonello; Ferri, Gaia; Ragazzini, Gregorio

    2013-01-01

    As a contribution to the study of the habitability of extrasolar planets, we implemented a one-dimensional energy balance model (EBM), the simplest seasonal model of planetary climate, with new prescriptions for most physical quantities. Here we apply our EBM to investigate the surface habitability of planets with an Earth-like atmospheric composition but different levels of surface pressure. The habitability, defined as the mean fraction of the planet's surface on which liquid water could exist, is estimated from the pressure-dependent liquid water temperature range, taking into account seasonal and latitudinal variations of surface temperature. By running several thousands of EBM simulations we generated a map of the habitable zone (HZ) in the plane of the orbital semi-major axis, a, and surface pressure, p, for planets in circular orbits around a Sun-like star. As pressure increases, the HZ becomes broader, with an increase of 0.25 AU in its radial extent from p = 1/3 to 3 bar. At low pressure, the habitability is low and varies with a; at high pressure, the habitability is high and relatively constant inside the HZ. We interpret these results in terms of the pressure dependence of the greenhouse effect, the efficiency of horizontal heat transport, and the extent of the liquid water temperature range. Within the limits discussed in the paper, the results can be extended to planets in eccentric orbits around non-solar-type stars. The main characteristics of the pressure-dependent HZ are modestly affected by variations of planetary properties, particularly at high pressure.

  4. Total number of tillers of different accessions of Panicum maximum Jacq.

    Directory of Open Access Journals (Sweden)

    Thiago Perez Granato

    2012-12-01

    Full Text Available The productivity of forage grasses is due to continuous emission of leaves and tillers, ensuring the restoration of leaf área after cutting or grazing, thus ensuring the sustainability of forage. This study aimed to asses the total number tillers in different acessions of Panicum maximum Jacq. The experiment was carried in field belonging to the Instituto de Zootecnia located in Nova Odessa / SP. Evaluated two new accesses Panicum maximum, and two commercial cultivars. The cultivars tested were Aruana, Milenio, NO 2487, NO 78, and the two latter belonging to the Germoplasm Collection of the IZ. The experimental desing was in randomized complete block with four replications. The experimental area consisted of 16 plots of 10 m2 (5 x 2 m each. The experimental area was analyzed and according to the results, received dolomitic limestone corresponding 2t /ha, two months before the implementation of the experiment. Sowing was made by broad costing together with 80 kg/ha of P2O5 in the form of single superphosfate. After 60 days of implantation of the experiment it was a made a leveling of the plots to a height of about 15 cm. After this it was applied 250g of the 20-00-20 fertilizer/plot. Thirty days after the standardization it was evaluated the total number of tillers of the cultivars, using a metal frame of 0.5 x 0.5m which was thrown at random on each of the 16 plots, leaving one meter of each extremitly, and all tillers which were within the frame counted. After finished the counting of all tillers, the plots cut again at a height of approximately 15 cm. The second evaluation took place after thirty days, and it was again counted the total number of tillers following the same procedure. The results were analyzed by Tukey test at 5% after transforming the data to log(x. For the first evaluation there was no statistical difference in the total number of tillers between cultivars. But, in the second evaluation, the total number of tillers of NO 78

  5. Assessment of intraocular pressure in chinchillas of different age groups using rebound tonometry

    Directory of Open Access Journals (Sweden)

    Flor Diana Yokoay Claros Chacaltana

    2016-01-01

    Full Text Available ABSTRACT: The aim of this research was to measure the intraocular pressure (IOP of normal chinchilla eyes using the rebound tonometer. A further aim was to assess whether there were differences in the values of intraocular pressure in relation to animals age, gender and time of day. Thirty-six chinchillas were divided into three groups of 12 chinchillas each, by age: Group I (2-6-month-old, Group II (20 and 34 months and Group III (37 and 135 months. Ophthalmic examination was performed previously by Schirmer tear test, slit lamp biomicroscopy, indirect ophthalmoscopy and fluorescein test in all chinchillas. Three measurements of intraocular pressure were assessed on the same day (7, 12 and 19h. Tonometry was performed on both eyes using the rebound tonometer after calibration in "p" mode. Statistical analysis was performed with SigmaPlot for Windows. The mean IOP for groups I, II and III were 2.47±0.581mmHg, 2.47±0.581mmHg and 2.51±0.531mmHg, respectively. No significant differences were reported between age and IOP and no significant differences were reported between the time of day and IOP. The IOP in chinchillas did not differ significantly between genders or ages of the animals, and did not change with time of day.

  6. ANTIOXIDANT ACTIVITY, TOTAL PHENOLIC AND FLAVONOID CONTENT OF MORINDA CITRIFOLIA FRUIT EXTRACTS FROM VARIOUS EXTRACTION PROCESSES

    Directory of Open Access Journals (Sweden)

    PRAVEEN K. RAMAMOORTHY

    2007-04-01

    Full Text Available Soxhlet, Ultrasonic extract of Morinda citrifolia L. fruit and four extracts from high pressure extraction at 10 MPa using ethanol, ethyl acetate as solvent and dried by vacuum oven and spray dryer were analyzed for their antioxidant activity by peroxide value method and diphenylpicrylhydrazyl radical scavenging method. The five extracts along with the reference samples, butylated hydroxyl toluene and tannic acid were further analyzed to determine their total phenolic content by Folin-Ciocalteau method and total flavonoid content by Dowd method. The M. citrifolia extract by high pressure extraction with ethyl acetate as solvent and spray dried was found to exhibit highest antioxidant activity and total flavonoid content. High total phenolic content was determined in the high pressure extract using ethyl acetate as solvent and vacuum dried. It was interesting to note that ultrasonic extract exhibited significant antioxidant activity, total phenolic and flavonoid content. High pressure extracted M. citrifolia in ethanol was found to express lesser values comparatively. The significant difference in activity among the high pressure extracts was found to be due to the polarity of the solvents used for extraction as M. citrifolia fruit contains relatively larger quantity of non-polar antioxidant compounds. It was also found that the drying methods had significant impact on the antioxidant activity, total phenolic and flavonoid content of the extracts.

  7. High pressure inactivation of relevant target microorganisms in poultry meat products and the evaluation of pressure-induced protein denaturation of marinated poultry under different high pressure treatments

    Science.gov (United States)

    Schmidgall, Johanna; Hertel, Christian; Bindrich, Ute; Heinz, Volker; Toepfl, Stefan

    2011-03-01

    In this study, the possibility of extending shelf life of marinated poultry meat products by high pressure processing was evaluated. Relevant spoilage and pathogenic strains were selected and used as target microorganisms (MOs) for challenge experiments. Meat and brine were inoculated with MOs and treated at 450 MPa, 4 °C for 3 min. The results of inactivation show a decreasing pressure tolerance in the series Lactobacillus > Arcobacter > Carnobacterium > Bacillus cereus > Brochothrix thermosphacta > Listeria monocytogenes. Leuconostoc gelidum exhibited the highest pressure tolerance in meat. A protective effect of poultry meat was found for L. sakei and L. gelidum. In parallel, the influence of different marinade formulations (pH, carbonates, citrates) on protein structure changes during a pressure treatment was investigated. Addition of sodium carbonate shows a protection against denaturation of myofibrillar proteins and provides a maximum water-holding capacity. Caustic marinades allowed a higher retention of product characteristics than low-pH marinades.

  8. Simultaneous compared with sequential blood pressure measurement results in smaller inter-arm blood pressure differences.

    Science.gov (United States)

    van der Hoeven, Niels V; Lodestijn, Sophie; Nanninga, Stephanie; van Montfrans, Gert A; van den Born, Bert-Jan H

    2013-11-01

    There are currently few recommendations on how to assess inter-arm blood pressure (BP) differences. The authors compared simultaneous with sequential measurement on mean BP, inter-arm BP differences, and within-visit reproducibility in 240 patients stratified according to age (simultaneous and three sequential BP measurements were taken in each patient. Starting measurement type and starting arm for sequential measurements were randomized. Mean BP and inter-arm BP differences of the first pair and reproducibility of inter-arm BP differences of the first and second pair were compared between both methods. Mean systolic BP was 1.3±7.5 mm Hg lower during sequential compared with simultaneous measurement (Psequential measurement was on average higher than the second, suggesting an order effect. Absolute systolic inter-arm BP differences were smaller on simultaneous (6.2±6.7/3.3±3.5 mm Hg) compared with sequential BP measurement (7.8±7.3/4.6±5.6 mm Hg, PSimultaneous measurement of BP at both arms reduces order effects and results in smaller inter-arm BP differences, thereby potentially reducing unnecessary referral and diagnostic procedures. ©2013 Wiley Periodicals, Inc.

  9. Investigating Gender Differences under Time Pressure in Financial Risk Taking.

    Science.gov (United States)

    Xie, Zhixin; Page, Lionel; Hardy, Ben

    2017-01-01

    There is a significant gender imbalance on financial trading floors. This motivated us to investigate gender differences in financial risk taking under pressure. We used a well-established approach from behavior economics to analyze a series of risky monetary choices by male and female participants with and without time pressure. We also used second to fourth digit ratio (2D:4D) and face width-to-height ratio (fWHR) as correlates of pre-natal exposure to testosterone. We constructed a structural model and estimated the participants' risk attitudes and probability perceptions via maximum likelihood estimation under both expected utility (EU) and rank-dependent utility (RDU) models. In line with existing research, we found that male participants are less risk averse and that the gender gap in risk attitudes increases under moderate time pressure. We found that female participants with lower 2D:4D ratios and higher fWHR are less risk averse in RDU estimates. Males with lower 2D:4D ratios were less risk averse in EU estimations, but more risk averse using RDU estimates. We also observe that men whose ratios indicate a greater prenatal exposure to testosterone exhibit a greater optimism and overestimation of small probabilities of success.

  10. EMG activities and plantar pressures during ski jumping take-off on three different sized hills.

    Science.gov (United States)

    Virmavirta, M; Perttunen, J; Komi, P V

    2001-04-01

    Different profiles of ski jumping hills have been assumed to make the initiation of take-off difficult especially when moving from one hill to another. Neuromuscular adaptation of ski jumpers to the different jumping hills was examined by measuring muscle activation and plantar pressure of the primary take-off muscles on three different sized hills. Two young ski jumpers volunteered as subjects and they performed several trials from each hill (K-35 m, K-65 m and K-90 m) with the same electromyographic (EMG) electrode and insole pressure transducer set-up. The results showed that the differences in plantar pressure and EMGs between the jumping hills were smaller than expected for both jumpers. The small changes in EMG amplitudes between the hills support the assumption that the take-off was performed with the same intensity on different jumping hills and the timing of the gluteus EMG demonstrates well the similarity of the muscle activation on different hills. On the basis of the results obtained it seems that ski jumping training on small hills does not disturb the movement patterns for bigger hills and can also be helpful for special take-off training with low speed.

  11. Significant interarm blood pressure difference predicts cardiovascular risk in hypertensive patients: CoCoNet study.

    Science.gov (United States)

    Kim, Su-A; Kim, Jang Young; Park, Jeong Bae

    2016-06-01

    There has been a rising interest in interarm blood pressure difference (IAD), due to its relationship with peripheral arterial disease and its possible relationship with cardiovascular disease. This study aimed to characterize hypertensive patients with a significant IAD in relation to cardiovascular risk. A total of 3699 patients (mean age, 61 ± 11 years) were prospectively enrolled in the study. Blood pressure (BP) was measured simultaneously in both arms 3 times using an automated cuff-oscillometric device. IAD was defined as the absolute difference in averaged BPs between the left and right arm, and an IAD ≥ 10 mm Hg was considered to be significant. The Framingham risk score was used to calculate the 10-year cardiovascular risk. The mean systolic IAD (sIAD) was 4.3 ± 4.1 mm Hg, and 285 (7.7%) patients showed significant sIAD. Patients with significant sIAD showed larger body mass index (P < 0.001), greater systolic BP (P = 0.050), more coronary artery disease (relative risk = 1.356, P = 0.034), and more cerebrovascular disease (relative risk = 1.521, P = 0.072). The mean 10-year cardiovascular risk was 9.3 ± 7.7%. By multiple regression, sIAD was significantly but weakly correlated with the 10-year cardiovascular risk (β = 0.135, P = 0.008). Patients with significant sIAD showed a higher prevalence of coronary artery disease, as well as an increase in 10-year cardiovascular risk. Therefore, accurate measurements of sIAD may serve as a simple and cost-effective tool for predicting cardiovascular risk in clinical settings.

  12. Different systolic blood pressure targets for people with history of stroke or transient ischaemic attack: PAST-BP (Prevention After Stroke—Blood Pressure) randomised controlled trial

    Science.gov (United States)

    McManus, Richard J; Roalfe, Andrea; Fletcher, Kate; Taylor, Clare J; Martin, Una; Virdee, Satnam; Greenfield, Sheila; Hobbs, F D Richard

    2016-01-01

    Objective To assess whether using intensive blood pressure targets leads to lower blood pressure in a community population of people with prevalent cerebrovascular disease. Design Open label randomised controlled trial. Setting 99 general practices in England, with participants recruited in 2009-11. Participants People with a history of stroke or transient ischaemic attack whose systolic blood pressure was 125 mm Hg or above. Interventions Intensive systolic blood pressure target (different target, patients in both arms were actively managed in the same way with regular reviews by the primary care team. Main outcome measure Change in systolic blood pressure between baseline and 12 months. Results 529 patients (mean age 72) were enrolled, 266 to the intensive target arm and 263 to the standard target arm, of whom 379 were included in the primary analysis (182 (68%) intensive arm; 197 (75%) standard arm). 84 patients withdrew from the study during the follow-up period (52 intensive arm; 32 standard arm). Mean systolic blood pressure dropped by 16.1 mm Hg to 127.4 mm Hg in the intensive target arm and by 12.8 mm Hg to 129.4 mm Hg in the standard arm (difference between groups 2.9 (95% confidence interval 0.2 to 5.7) mm Hg; P=0.03). Conclusions Aiming for target below 130 mm Hg rather than 140 mm Hg for systolic blood pressure in people with cerebrovascular disease in primary care led to a small additional reduction in blood pressure. Active management of systolic blood pressure in this population using a blood pressure. Trial registration Current Controlled Trials ISRCTN29062286. PMID:26919870

  13. The inversion of relative shear rigidity in different material classes at megabar pressures

    CERN Document Server

    Brazhkin, V V

    2002-01-01

    The behaviour of elastic moduli of substances is analysed in the megabar pressure range. A new effect - inversion of the shear moduli and mechanical properties upon compression - is predicted for various classes of substances. The melting-curve data for different materials confirm the predicted phenomenon. The materials traditionally considered the softest, such as rare-gas solids and molecular substances, may become the hardest in the megabar range. This should be taken into account in developing experimental high-pressure techniques.

  14. The difference in pediatric blood pressure between middle childhood and late childhood prior to dental treatment

    Directory of Open Access Journals (Sweden)

    Fitri Anissa Syaimima bt. Syaiful Azim

    2018-01-01

    Full Text Available Every child will go through several stages in his or her life. They are different from each other as they are in the process of development of cognition, physics, emotion, and personality. For many children, a visit to the dentist can raise their anxiety. This anxiousness will lead to stress that influences the cardiovascular function in the body. The purpose of this research was to determine the difference in pediatric blood pressure between middle childhood and late childhood prior to dental treatment. This research was a clinical trial, pure experimental study. The sample consisted of 30 children within the range of 4-12 years old where they were divided into two groups of age; middle childhood (4-7 years old and late childhood (8-12 years old. The blood pressures were measured before any dental treatment began and the values were recorded. The data were then analyzed using the One-Sample T-Test analysis. The results of blood pressure in middle childhood and late childhood were compared to the average mean values for each age group. It showed that there was a significant difference in the systolic pressure, which was found higher in the middle childhood group compared to the late childhood. From the result can be concluded that there was a difference in the pediatric blood pressure between middle childhood and late childhood prior to dental treatment.

  15. Association between Macronutrients Intake, Visceral Obesity and Blood Pressure in a Sample of Obese Egyptian Women.

    Science.gov (United States)

    Hassan, Nayera E; El Shebini, Salwa M; Ahmed, Nihad H; Selim Mostafa, Mohamed

    2015-03-15

    Study the association between the total caloric intake, protein, lipid, and some classes of fatty acids of the diet, and their effects on blood pressure in a sample of Egyptian obese women with and without visceral obesity. Five hundred forty-nine obese women were included in the study with mean age of 38.1 ± 11.56 years and mean Body mass index [BMI] of 36.17 ± 7.23. They enrolled in a program for losing weight. Visceral fat was determined using ultrasound. Blood pressure was measured 3 times and the mean was recorded. Twenty four hours dietary recall was reported. Thirty point four percentages of samples has visceral obesity ≥ 7cm; they were the older, showed higher values of BMI, visceral obesity and blood pressure. Significant difference was found between groups regarding mean value of BMI, visceral obesity, both systolic blood pressure SBP and diastolic blood pressure DBP and most of the daily macronutrients intake. In groups (2&3) positive significant correlation was recorded between (SBP) & (DBP) and total daily intake of total calories, carbohydrate, total fat, saturated fatty acids and cholesterol, and negative significant correlation with total daily intake of total protein, animal and vegetable protein, linolenic and linoleic fatty acids, while oleic fatty acid showed negative correlation with SBP&DBP in all groups. This study emphasizes the hypothesis that the macronutrients composition of diet influences blood pressure in different ways, in obese patients with visceral obesity.

  16. Custom-made different designs of pressure clips for the management of ear lobe keloids

    Directory of Open Access Journals (Sweden)

    Anshul Chugh

    2013-01-01

    Full Text Available Introduction : Keloids are frequent finding after physical trauma. Keloids of ear lobe are common complication of ear piercing, although its incidence remains unknown. The use of intrakeloid resection and a form pressure device to treat pinna keloids. The recommendation of this therapy is to maintain constant pressure and duration of pressure therapy was about 25 weeks. Clinical innovation : This article will present inexpensive custom made pressure clips of various designs. The dimensions of polymethylmethacrylate (PMMA plates in ear lobe clip presented by us though they esthetically not so good, but colored PMMA has been used to make it decorative and acceptable by most of the patients. This has been an encouraging experience to use the different designs. Discussion : Ear clip prosthesis has been developed for maintaining pressure on ear lobe keloids before and after surgical removal. The prosthesis includes an ear clip to which heat-polymerized acrylic resin is attached, which covers the keloid area. Pressure therapy is widely used to help in the early maturation of scar tissue and to prevent the recurrence of keloid. The preliminary report by Brent revealed that constant light pressure was an effective means of preventing post excision recurrence of ear lobe keloids using a decorative, spring-pressure earring.

  17. Prognostic significance of between-arm blood pressure differences.

    Science.gov (United States)

    Agarwal, Rajiv; Bunaye, Zerihun; Bekele, Dagim M

    2008-03-01

    Blood pressure (BP) recordings often differ between arms, but the extent to which these differences are reproducible and whether the differences have prognostic importance is unknown. We enrolled 421 consecutive patients from a medicine and a renal clinic at a veterans' hospital. Three BP recordings were obtained in each arm using an oscillometric device in a sequential manner and repeated in 1 week. Patients were followed for all-cause mortality arm had 5.1-mm Hg higher systolic BP that attenuated by approximately 2.2 mm Hg a week later. Systolic BP dropped 6.9 mm Hg over 1 week and by an additional 5.3 mm Hg in patients with chronic kidney disease. Accounting for the visit and arm effect improved the reproducibility of the BP measurements. The intraclass correlation coefficient was 0.74, which improved to 0.88 after accounting for visit and 0.93 after accounting for arm. The crude mortality rate was 6.33 per 100 patient-years. Every 10-mm Hg difference in systolic BP between the arms conferred a mortality hazard of 1.24 (95% CI: 1.01 to 1.52) after adjusting for average systolic BP and chronic kidney disease. BP differences between arms are reproducible and carry prognostic information. Patients should have evaluation of BP in both arms at the screening visit.

  18. Trpv4 involvement in the sex differences in blood pressure regulation in spontaneously hypertensive rats.

    Science.gov (United States)

    Onishi, Makiko; Yamanaka, Ko; Miyamoto, Yasunori; Waki, Hidefumi; Gouraud, Sabine

    2018-04-01

    Arterial pressure (AP) is lower in premenopausal women than in men of a similar age. Premenopausal women exhibit a lower sympathetic activity and a greater baroreceptor reflex; however, mechanisms controlling sex differences in blood pressure regulation are not well understood. We hypothesized that different neuronal functions in the cardiovascular centers of the brains of men and women may contribute to the sex difference in cardiovascular homeostasis. Our previous studies on male spontaneously hypertensive rats (SHRs) and their normotensive counterparts, Wistar Kyoto (WKY) rats, revealed that the gene-expression profile of the nucleus tractus solitarius (NTS), a region of the medulla oblongata that is pivotal for regulating the set point of AP, is strongly associated with AP. Thus, we hypothesized that gene-expression profiles in the rat NTS are related to sex differences in AP regulation. Because female SHRs clearly exhibit lower AP than their male counterparts of a similar age, we investigated whether SHR NTS exhibits sex differences in gene expression by using microarray and RT-qPCR experiments. The transcript for transient receptor potential cation channel subfamily V member 4 ( Trpv4) was found to be upregulated in SHR NTS in females compared with that in males. The channel was expressed in neurons and glial cells within NTS. The TRPV4 agonist 4-alpha-phorbol-12,13-didecanoate (4α-PDD) decreased blood pressure when injected into NTS of rats. These findings suggest that altered TRPV4 expression might be involved in the sex differences in blood pressure regulation.

  19. Pressure loss characteristics of LSTF steam generator heat-transfer tubes. Pressure loss increase due to tube internal instruments

    International Nuclear Information System (INIS)

    Suzuki, Mitsuhiro

    1994-11-01

    The steam generator of the Large-Scale Test Facility (LSTF) includes 141 heat-transfer U-tubes with different lengths. Six U-tubes among them are furnished with 15 or 17 probe-type instruments (conduction probe with a thermocouple; CPT) protuberant into the primary side of the U-tubes. Other 135 U-tubes are not instrumented. This results in different hydraulic conditions between the instrumented and non-instrumented U-tubes with the same length. A series of pressure loss characteristics tests was conducted at a test apparatus simulating both types of U-tube. The following pressure loss coefficient (K CPT ) was reduced as a function of Reynolds number (Re) from these tests under single-phase water flow conditions. K CPT =0.16 5600≤Re≤52820, K CPT =60.66xRe -0.688 2420≤Re≤5600, K CPT =2.664x10 6 Re -2.06 1371≤Re≤2420. The maximum uncertainty is 22%. By using these results, the total pressure loss coefficients of full length U-tubes were estimated. It is clarified that the total pressure loss of the shortest instrumented U-tube is equivalent to that of the middle-length non-instrumented U-tube and also that a middle-length instrumented U-tube is equivalent to the longest non-instrumented U-tube. Concludingly. it is important to take account of the CPT pressure loss mentioned above in estimation of fluid behavior at the non-instrumented U-tubes either by using the LSTF experiment data from the CPT-installed U-tubes or by using any analytical codes. (author)

  20. Features of blood pressure in student-athletes from different directions of the training process.

    Directory of Open Access Journals (Sweden)

    Kalenichenko Aleksej Vladimirovich

    2011-11-01

    Full Text Available Performed blood pressure (BP and hemodynamics of 85 students: 30 non-athletes (group I, 27 athletes power enforcement types (group II and 28 - endurance sports (group III. It was found that the second and third groups had higher systolic and mean arterial pressure than in the I group. There are differences in blood pressure reactivity to changes in body position, mental and physical activity among the various groups studied. It is shown that the formation of moderate hypertension in group III is carried out by increasing peripheral vascular resistance, and II - at the expense of increased cardiac output.

  1. High hydrostatic pressure resistance of Campylobacter jejuni after different sublethal stresses.

    Science.gov (United States)

    Sagarzazu, N; Cebrián, G; Condón, S; Mackey, B; Mañas, P

    2010-07-01

    To study the development of resistance responses in Campylobacter jejuni to high hydrostatic pressure (HHP) treatments after the exposure to different stressful conditions that may be encountered in food-processing environments, such as acid pH, elevated temperatures and cold storage. Campylobacter jejuni cells in exponential and stationary growth phase were exposed to different sublethal stresses (acid, heat and cold shocks) prior to evaluate the development of resistance responses to HHP. For exponential-phase cells, neither of the conditions tested increased nor decreased HHP resistance of C. jejuni. For stationary-phase cells, acid and heat adaptation-sensitized C. jejuni cells to the subsequent pressure treatment. On the contrary, cold-adapted stationary-phase cells developed resistance to HHP. Whereas C. jejuni can be classified as a stress sensitive micro-organism, our findings have demonstrated that it can develop resistance responses under different stressing conditions. The resistance of stationary phase C. jejuni to HHP was increased after cells were exposed to cold temperatures. The results of this study contribute to a better knowledge of the physiology of C. jejuni and its survival to food preservation agents. Results here presented may help in the design of combined processes for food preservation based on HHP technology. © 2009 The Authors. Journal compilation © 2009 The Society for Applied Microbiology.

  2. Relation between preoperative autonomic function and blood pressure change after tourniquet deflation during total knee replacement arthroplasty.

    Science.gov (United States)

    Huh, In Young; Kim, Dae-Young; Lee, Ji-Hyeon; Shin, Soo Jin; Cho, Young Woo; Park, Soon Eun

    2012-02-01

    Tourniquets are used to provide a bloodless surgical field for extremities. Hypotension due to vasodilation and bleeding after tourniquet deflation is a common event. Hemodynamic stability is modulated by the autonomic nervous system (ANS). Heart rate variability (HRV) is a sensitive method for detecting individuals who may be at risk of hemodynamic instability during general anesthesia. The purpose of this study was to investigate ANS function to predict hypotension after tourniquet deflation. Eighty-six patients who underwent total knee replacement arthroplasty (TKRA) were studied. HRV, systolic blood pressure variability (SBPV) and baroreflex sensitivity (BRS) were analyzed. We assigned two groups depending on the lowest systolic blood pressure (SBP) or mean BP (MBP) after tourniquet release (Group H; SBP 80 mmHg and MBP > 60 mmHg). Fifteen patients developed severe hypotension and ten patients were treated with ephedrine. Of the parameters of HRV, SBPV, and BRS, only BRS(SEQ) was significant being low in Group H. BRS and high-frequency SBPV were correlated with the degree of MBP change after tourniquet deflation. Preoperative low BRS is associated with hypotension after tourniquet deflation, suggesting the importance of baroreflex regulation for intraoperative hemodynamic stability.

  3. Analysis of Total Electron Content and Electron Density Profile during Different Geomagnetic Storms

    Science.gov (United States)

    Chapagain, N. P.; Rana, B.; Adhikari, B.

    2017-12-01

    Total Electron content (TEC) and electron density are the key parameters in the mitigation of ionospheric effects on radio communication system. Detail study of the TEC and electron density variations has been carried out during geomagnetic storms, with longitude and latitude, for four different locations: (13˚N -17˚N, 88˚E -98˚E), (30˚N-50˚N, 120˚W -95˚W), (29˚S-26˚S, 167˚W-163˚W,) and (60˚S-45˚S, 120˚W-105˚W) using the Gravity Recovery and Climate Experiment (GRACE) satellite observations. In order to find the geomagnetic activity, the solar wind parameters such as north-south component of inter planetary magnetic field (Bz), plasma drift velocity (Vsw), flow pressure (nPa), AE, Dst and Kp indices were obtained from Operating Mission as Nodes on the Internet (OMNI) web system. The data for geomagnetic indices have been correlated with the TEC and electron density for four different events of geomagnetic storms on 6 April 2008, 27 March 2008, 4 September 2008, and 11 October 2008. The result illustrates that the observed TEC and electron density profile significantly vary with longitudes and latitudes. This study illustrates that the values of TEC and the vertical electron density profile are influenced by the solar wind parameters associated with solar activities. The peak values of electron density and TEC increase as the geomagnetic storms become stronger. Similarly, the electron density profile varies with altitudes, which peaks around the altitude range of about 250- 350 km, depending on the strength of geomagnetic storms. The results clearly show that the peak electron density shifted to higher altitude (from about 250 km to 350 km) as the geomagnetic disturbances becomes stronger.

  4. A piezo-bar pressure probe

    Science.gov (United States)

    Friend, W. H.; Murphy, C. L.; Shanfield, I.

    1967-01-01

    Piezo-bar pressure type probe measures the impact velocity or pressure of a moving debris cloud. It measures pressures up to 200,000 psi and peak pressures may be recorded with a total pulse duration between 5 and 65 musec.

  5. Blood pressure differences between arms and association of dominant hands with blood pressure differences and carotid atherosclerosis.

    Science.gov (United States)

    Maeda, Shinji

    2013-06-01

    Guidelines for the management of hypertension recommend that blood pressure (BP) should be measured twice at every visit; it should be measured in both arms at the first visit, and the right arm BP or higher BP should be recorded. Manufacturers of home BP monitors tend to design the device for measurement of left arm BP. The arm preferred for BP measurement differs according to the methods recommended by the society and according to the home BP monitors. The BP difference (ΔBP) is calculated by subtracting left arm BP from right arm BP. Here, we aim to first investigate which hand will give the most accurate reading by a sphygmomanometer in daily medical practice. Second, we wish to assess the association of the dominant hand with absolute BP difference (|ΔBP|) of at least 10 mmHg and with early atherosclerotic markers in a subanalysis. We found that 6.4% of outpatients were left handed, and the percentage of individuals with systolic |ΔBP| (|ΔSBP|) and diastolic |ΔBP| (|ΔDBP|) of at least 10 mmHg was 14.4 and 7.2%, respectively. The dominant hand was not significantly associated with |ΔBP| of at least 10 mmHg or early atherosclerotic markers. This study suggests that BP measured in one arm is substitutable with that of the other arm because of a lack of association of |ΔBP| with the dominant hand. However, BP of both arms should be actively measured in new outpatients with moderate fever, lifestyle-related diseases, vascular events, age 65 years and above, and smoking history, all of which are factors potentially associated with |ΔBP| of at least 10 mmHg, regardless of the dominant hand.

  6. Sex differences in obesity associated with total fertility rate.

    Directory of Open Access Journals (Sweden)

    Robert Brooks

    Full Text Available The identification of biological and ecological factors that contribute to obesity may help in combating the spreading obesity crisis. Sex differences in obesity rates are particularly poorly understood. Here we show that the strong female bias in obesity in many countries is associated with high total fertility rate, which is well known to be correlated with factors such as low average income, infant mortality and female education. We also document effects of reduced access to contraception and increased inequality of income among households on obesity rates. These results are consistent with studies that implicate reproduction as a risk factor for obesity in women and that suggest the effects of reproduction interact with socioeconomic and educational factors. We discuss our results in the light of recent research in dietary ecology and the suggestion that insulin resistance during pregnancy is due to historic adaptation to protect the developing foetus during famine. Increased access to contraception and education in countries with high total fertility rate might have the additional benefit of reducing the rates of obesity in women.

  7. Velocity-pressure correlation measurements in complex free shear flows

    International Nuclear Information System (INIS)

    Naka, Yoshitsugu; Obi, Shinnosuke

    2009-01-01

    Simultaneous measurements of fluctuating velocity and pressure were performed in various turbulent free shear flows including a turbulent mixing layer and the wing-tip vortex trailing from a NACA0012 half-wing. Two different methods for fluctuating static pressure measurement were considered: a direct method using a miniature Pitot tube and an indirect method where static pressure was calculated from total pressure. The pressure obtained by either of these methods was correlated with the velocity measured by an X-type hot-wire probe. The results from these two techniques agreed with each other in the turbulent mixing layer. In the wing-tip vortex case, however, some discrepancies were found, although overall characteristics of the pressure-related statistics were adequately captured by both methods.

  8. Application of vacuum-assisted closure in seawater-immersed wound treatment under different negative pressures.

    Science.gov (United States)

    Cao, L; Peng, M M; Sun, J J; Yu, X C; Shi, B

    2015-06-11

    The therapeutic effect of vacuum-assisted closure (VAC) has been confirmed in many types of complex wounds, but there are few relevant reports regarding seawater-immersed wounds. The aim of this study was to determine the effect of VAC on seawater-immersed wound healing under different negative pressures and explore the optimal negative pressure value. Four purebred miniature pigs were used as the experimental animal models. Four acute, symmetrical wounds were made on each side of the spine and designated as the experimental group (wounds with 2 h of seawater immersion) and the control group (wounds without seawater immersion). Wounds were divided into a conventional dressing group and 3 further groups with different VAC therapies (negative pressure at either 120, 180, or 240 mmHg). The extent of wound healing, and speed of granulation growth and re-epithelialization were measured. Bacterial flora distribution in the wounds was observed, and fibronectin levels in the exudate of the wounds were tested. Results showed that seawater immersion aggravated wound injury and that VAC therapy with 180 mmHg negative pressure induced the fastest epidermis migration, obvious edema elimination, significant capillary proliferation, and the highest level of fibronectin, and that in wounds, the proportion of Gram-negative bacteria tended to decrease and that of Gram-positive bacteria tended to increase. Our results show that VAC promotes seawater-immersed wound healing and that 180 mmHg negative pressure may be optimal for wound healing.

  9. The difference in blood pressure readings between arms and survival: primary care cohort study

    OpenAIRE

    Clark, Christopher E; Taylor, Rod S; Shore, Angela C; Campbell, John L

    2012-01-01

    Objective To determine whether a difference in systolic blood pressure readings between arms can predict a reduced event free survival after 10 years. Design Cohort study. Setting Rural general practice in Devon, United Kingdom. Participants 230 people receiving treatment for hypertension in primary care. Intervention Bilateral blood pressure measurements recorded at three successive surgery attendances. Main outcome measures Cardiovascular events and deaths from all causes during a median fo...

  10. Validation of the SCIAN LD-735 wrist blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol revision 2010.

    Science.gov (United States)

    Kang, Yuan-Yuan; Chen, Qi; Li, Yan; Wang, Ji-Guang

    2016-08-01

    This study aimed to evaluate the accuracy of the automated oscillometric wrist blood pressure monitor SCIAN LD-735 for home blood pressure monitoring according to the International Protocol of the European Society of Hypertension revision 2010. Systolic and diastolic blood pressures were measured sequentially in 33 adult Chinese participants (10 women, mean age 44.8 years) using a mercury sphygmomanometer (two observers) and the SCIAN LD-735 device (one supervisor). A total of 99 pairs of comparisons were obtained from 33 participants for judgments in two parts with three grading phases. The SCIAN LD-735 device achieved the targets in part 1 of the validation study. The number of absolute differences between device and observers within 5, 10, and 15 mmHg was 86/99, 97/99, and 98/99, respectively, for systolic blood pressure and 85/99, 98/99, and 99/99, respectively, for diastolic blood pressure. The device also fulfilled the criteria in part 2 of the validation study. In total, 30 and 33 participants for systolic and diastolic blood pressure, respectively, had at least two of the three device-observer differences within 5 mmHg (required ≥24). No participant had all of the three device-observer comparisons greater than 5 mmHg for systolic or diastolic blood pressure. The SCIAN wrist blood pressure monitor LD-735 has passed the requirements of the International Protocol revision 2010, and hence can be recommended for home use in adults.

  11. Comparison of Different Turbulence Models for Numerical Simulation of Pressure Distribution in V-Shaped Stepped Spillway

    Directory of Open Access Journals (Sweden)

    Zhaoliang Bai

    2017-01-01

    Full Text Available V-shaped stepped spillway is a new shaped stepped spillway, and the pressure distribution is quite different from that of the traditional stepped spillway. In this paper, five turbulence models were used to simulate the pressure distribution in the skimming flow regimes. Through comparing with the physical value, the realizable k-ε model had better precision in simulating the pressure distribution. Then, the flow pattern of V-shaped and traditional stepped spillways was given to illustrate the unique pressure distribution using realizable k-ε turbulence model.

  12. The Phase Envelope of Multicomponent Mixtures in the Presence of a Capillary Pressure Difference

    DEFF Research Database (Denmark)

    Sandoval Lemus, Diego Rolando; Yan, Wei; Michelsen, Michael Locht

    2016-01-01

    for test mixtures with wide ranges of compositions at different capillary radii and vapor fractions. The calculation results show that the phase envelope changes everywhere except at the critical point. The bubble point and the lower branch of the dew point show a decrease in the saturation pressure......, whereas the upper branch of the dew point shows an increase. The cricondentherm is shifted to a higher temperature. We also presented a mathematical analysis of the phase envelope shift due to capillary pressure based on linear approximations. The resulting linear approximation equations can predict...... the magnitude of shift, and the approximation is close for the change in the bubble point pressure....

  13. The effect of different skin-ankle brace application pressures on quiet single-limb balance and electromyographic activation onset of lower limb muscles

    Directory of Open Access Journals (Sweden)

    Papadakis Stamatios A

    2007-09-01

    Full Text Available Abstract Background Several studies have been carried out in order to investigate the effect of ankle bracing on ankle joint function and performance. However, no study so far has examined the role of skin-brace interface pressure in neuromuscular control. The aim of this study was to investigate the effect of different skin-ankle brace interface pressures on quiet single limb balance and the electromyographic (EMG activation sequence of four lower limb muscles. Methods Thirty three male physical education students who volunteered to take part in the study were measured under three ankle brace conditions: i without brace, ii with brace and 30 kPa application pressure and iii with brace and 60 kPa application pressure. Single limb balance (anteroposterior and mediolateral parameter was assessed on the dominant lower limb, with open and closed eyes, on a force platform, simultaneously with the EMG recording of four lower lower limb muscles' (gastrocnemius, peroneus longus, rectus femoris and biceps femoris activation onset. Results The results showed that overall balance (total stability parameter was not significantly affected in any of the three ankle brace conditions. However, the anteroposterior centre of pressure excursion and centre of pressure excursion velocity were significantly increased with the application of ankle brace, both with 30 and 60 kPa application pressures. Furthermore, it was found that single limb balance was significantly worse with closed eyes compared to open eyes. EMG measurements showed that the sequence of lower limb activation onset was not affected in any of the three ankle brace application conditions. The results of this study showed that the application of an ankle brace with two different skin-brace interface pressures had no effect on overall single limb balance and the sequence of lower limb muscle activation. Conclusion These findings suggest that peripheral joint receptors are either not adequately

  14. Determinants of the Morning-Evening Home Blood Pressure Difference in Treated Hypertensives: The HIBA-Home Study

    Directory of Open Access Journals (Sweden)

    Lucas S. Aparicio

    2014-01-01

    Full Text Available Background. The morning home blood pressure (BP rise is a significant asymptomatic target organ damage predictor in hypertensives. Our aim was to evaluate determinants of home-based morning-evening difference (MEdiff in Argentine patients. Methods. Treated hypertensive patients aged ≥18 years participated in a cross-sectional study, after performing home morning and evening BP measurement. MEdiff was morning minus evening home average results. Variables identified as relevant predictors were entered into a multivariable linear regression analysis model. Results. Three hundred sixty-seven medicated hypertensives were included. Mean age was 66.2 (14.5, BMI 28.1 (4.5, total cholesterol 4.89 (1.0 mmol/L, 65.9% women, 11.7% smokers, and 10.6% diabetics. Mean MEdiff was 1.1 (12.5 mmHg systolic and 2.3 (6.1 mmHg diastolic, respectively. Mean self-recorded BP was 131.5 (14.1 mmHg systolic and 73.8 (7.6 mmHg diastolic, respectively. Mean morning and evening home BPs were 133.1 (16.5 versus 132 (15.7 systolic and 75.8 (8.4 versus 73.5 (8.2 diastolic, respectively. Significant beta-coefficient values were found in systolic MEdiff for age and smoking and in diastolic MEdiff for age, smoking, total cholesterol, and calcium-channel blockers. Conclusions. In a cohort of Argentine medicated patients, older age, smoking, total cholesterol, and use of calcium channel blockers were independent determinants of home-based MEdiff.

  15. Selective serotonin reuptake inhibitors and intraoperative blood pressure.

    Science.gov (United States)

    van Haelst, Ingrid M M; van Klei, Wilton A; Doodeman, Hieronymus J; Kalkman, Cor J; Egberts, Toine C G

    2012-02-01

    The influence of selective serotonin reuptake inhibitors (SSRIs) on blood pressure is poorly understood. We hypothesized that if SSRIs have an influence on blood pressure, this might become manifest in changes in intraoperative blood pressure. We aimed to study the association between perioperative use of SSRIs and changes in intraoperative blood pressure by measuring the occurrence of intraoperative hyper- and hypotension. We conducted a retrospective observational follow-up study among patients who underwent elective primary total hip arthroplasty. The index group included users of SSRIs. The reference group included a random sample (ratio 1:3) of nonusers of an antidepressant agent. The outcome was the occurrence of intraoperative hypo- and hypertensive episodes (number, mean and total duration, and area under the curve (AUC)). The outcome was adjusted for confounding factors using regression techniques. The index group included 20 users of an SSRI. The reference group included 60 nonusers. Users of SSRIs showed fewer intraoperative hypotensive episodes, a shorter mean and total duration, and a smaller AUC when compared to the reference group. After adjustment for confounders, SSRI use was associated with a significantly shorter total duration of hypotension: mean difference of -29.4 min (95% confidence interval (CI) -50.4 to -8.3). Two users of an SSRI and two patients in the reference group had a hypertensive episode. Continuation of treatment with SSRIs before surgery was associated with a briefer duration of intraoperative hypotension.

  16. [Comparison of different continuous positive airway pressure titration methods for obstructive sleep apnea hypopnea syndrome].

    Science.gov (United States)

    Li, Jingjing; Ye, Jingying; Zhang, Peng; Kang, Dan; Cao, Xin; Zhang, Yuhuan; Ding, Xiu; Zheng, Li; Li, Hongguang; Bian, Qiuli

    2014-10-01

    To explore whether there were differences between the results of automatic titration and the results of manual titration for positive airway pressure treatment in patients with obstructive sleep apnea hypopnea syndrome (OSAHS) and its influencing factors, the results might provide a theoretical basis for the rational use of two pressure titration methods. Sixty one patients with OSAHS were included in this study. All patients underwent a manual titration and an automatic titration within one week. The clinical informations, polysomnography data, and the results of both two titration of all patients were obtained for analysis. The overall apnea/hypopnea index was (63.1 ± 17.7)/h, with a range of 14.9/h to 110.4/h. The treatment pressure of manual titration was (8.4 ± 2.1) cmH(2)O, which was significantly lower than the treatment pressure of automatic titration, (11.5 ± 2.7) cmH(2)O (t = -9.797, P titration and manual titration), it was found that the pressure of automatic titration was significantly higher in patients with a ΔP > 3 cmH(2)O than in patients with a ΔP ≤ 3 cmH(2)O, which was (13.3 ± 2.3) cmH(2)O vs (10.0 ± 2.0) cmH(2)O (t = -6.159, P titration between these two groups, which was (8.6 ± 2.4) cmH(2)O vs (8.3 ± 2.0)cmH(2)O (P > 0.05). There was no significant difference in age, body mass index, neck circumference, abdomen circumference, apnea hypopnea index, and arterial oxygen saturation between these two groups. The treatment pressure of automatic titration is usually higher than that of manual titration. For patients with a high treatment pressure which is derived from automatic titration, a suggestion about manual titration could be given to decrease the potential treatment pressure of continuous positive airway pressure, which may be helpful in improving the comfortableness and the compliance of this treatment.

  17. Appraising and comparing pressure ulcer guidelines.

    Science.gov (United States)

    Wimpenny, Peter; van Zelm, Ruben

    2007-01-01

    Whilst considerable activity has been related to guideline development for nurses regarding pressure ulcer prevention and management, no attempt has been made to comparatively evaluate these guidelines against some form of quality indicators. To compare and contrast four national pressure ulcer guidelines, and identify similarities and differences in their quality and content. An international comparative appraisal method, using the AGREE (Appraisal of Guidelines Research and Evaluation) instrument, was undertaken to appraise four published pressure ulcer guidelines. Two further domains were added to the AGREE instrument to assess comparability of the guidelines and their perceived contribution to practice. An international group undertook the comparative appraisal. The domain scores for each guideline show some but not total agreement among reviewers. One particular set of guidelines was identified as scoring highest in a majority of AGREE domains. Overall, evidence of variability exists between pressure ulcer guidelines and common areas of development to consider for all guidelines. The results raise many questions concerning the "best" pressure ulcer guideline to use, particularly related to the AGREE scoring. Some notable shortcomings exist in all the pressure ulcer guidelines reviewed and these shortcomings need to be addressed from a quality perspective. However, other issues such as style of reporting and potential contribution to practice might more fully affect choice by practitioners as opposed to guideline developers. Notable differences exist among the four guidelines that are possibly explained by different approaches to development and also because of different cultural factors and intentions for use. Whilst the AGREE tool identifies the quality of the guideline development process it still requires local engagement with practitioners to determine which guideline should be implemented.

  18. Gingival blood flow under total combs by functional pressure evaluated with laser-Doppler flowmetry, a non-invasive method of blood flow measurement

    International Nuclear Information System (INIS)

    Hengl, St.

    1996-09-01

    Gingival blood flow under total-combs by functional pressure evaluated with Laser-Doppler Flowmetry, a non-invasive method of blood flow measurement. Microcirculation of gum's capillary system can be measured non-invasive by Laser-Doppler-Flowmetry (LDF). Circulation, defined by the number of floating erythrocytes per unit of time, is measured by a fibro-optical Laser-Doppler-Flowmetry. The task was to examine, if there is any change of gum's circulation during strain and relief. Circulation on defined measurepoints, divided on the four quadrants, was determined among maximal strain and subsequent relief, on one probationer (complete denture bearer). Before every measure session systemic pressure was taken. LDF-value was taken on top of jaw-comb, in doing so, to get reproducible result and a satisfying fixation of the probe, there was made an artificial limb of the upper and lower comb. In the upper comb a dynamometer-box, which determined minimal and maximal comb pressure, was integrated. The received results of the LDF-measurement, expressed as perfusion units (PU) were lower under applied pressure than by pressure points more distant. Hyperemia, resulting during relief, seemed the more intense, the less perfusion was before. This new, non-invasive kind of circulation measurement seems to be quite predestined to be used for gingival diagnostic under artificial limb in the future. (author)

  19. Vapor pressure and vapor fractionation of silicate melts of tektite composition

    Science.gov (United States)

    Walter, Louis S.; Carron, M.K.

    1964-01-01

    The total vapor pressure of Philippine tektite melts of approximately 70 per cent silica has been determined at temperatures ranging from 1500 to 2100??C. This pressure is 190 ?? 40 mm Hg at 1500??C, 450 ?? 50 mm at 1800??C and 850 ?? 70 mm at 2100?? C. Determinations were made by visually observing the temperature at which bubbles began to form at a constant low ambient pressure. By varying the ambient pressure, a boiling point curve was constructed. This curve differs from the equilibrium vapor pressure curve due to surface tension effects. This difference was evaluated by determining the equilibrium bubble size in the melt and calculating the pressure due to surface tension, assuming the latter to be 380 dyn/cm. The relative volatility from tektite melts of the oxides of Na, K, Fe, Al and Si has been determined as a function of temperature, total pressure arid roughly, of oxygen fugacity. The volatility of SiO2 is decreased and that of Na2O and K2O is increased in an oxygen-poor environment. Preliminary results indicate that volatilization at 2100??C under atmospheric pressure caused little or no change in the percentage Na2O and K2O. The ratio Fe3 Fe2 of the tektite is increased in ambient air at a pressure of 9 ?? 10-4 mm Hg (= 106.5 atm O2, partial pressure) at 2000??C. This suggests that tektites were formed either at lower oxygen pressures or that they are a product of incomplete oxidation of parent material with a still lower ferricferrous ratio. ?? 1964.

  20. [Is blood pressure control different in women than in men?].

    Science.gov (United States)

    Oliveras, A; Sans-Atxer, L; Vázquez, S

    2015-01-01

    Blood pressure (BP) evolves with age; until the 50's it is higher in men than in women, equaling and even then increasing in women. The prevalence of controlled BP appears to be similar between the sexes, but the prevalence of cardiovascular disease is higher in women than in men. The possibility that BP influences the cardiovascular risk differently according to sex must therefore be considered. While some studies suggest no difference exists, others have shown evidence of an increased risk in women with respect to men despite equal BP. In this way, it seems that the measurement of ambulatory BP, but not office BP, would mark the differences in the association between BP-gender and cardiovascular risk. It should therefore be investigated the possibility of a different BP goal for women and men, especially by evaluating ambulatory BP. Copyright © 2015 SEHLELHA. Published by Elsevier España, S.L.U. All rights reserved.

  1. Evaluation of the diurnal intraocular pressure fluctuations and blood pressure under dehydration due to fasting

    Directory of Open Access Journals (Sweden)

    Gonen Baser

    2016-12-01

    Full Text Available Introduction: This study aimed to investigate the diurnal intraocular pressure fluctuations under dehydration conditions and the relationship between the intraocular pressure fluctuations and blood pressure. Methods: The intraocular pressures (IOP, body weights, as well as systolic and diastolic blood pressures (SBP, DBP of 36 fasting healthy volunteers were recorded at 8:00 a.m. and 5:00 p.m. in the Ramadan of 2014 and two weeks after it. The data were analyzed using paired Student’s t-test and Pearson correlation analysis. Results: As the results demonstrated, the mean diurnal IOP differences of IOP, SBP, DBP, and weight were 2.67±1.33 mmHg, 9.44±8.02 mmHg, 3.33±5.94 mmHg, and 0.90±0.46 kg during the fasting period, respectively. In addition, the mean diurnal IOP differences of IOP, SBP, DBP, and weight were -0.33±1.4 mmHg (P=0.001, 0.55±7.25mmHg (P=0.003, -3.33±5.94 mmHg (P=0.001, and 0.12±0.45 kg (P=0.001 during the control period, respectively. There was a moderate correlation between the diurnal IOP and SBP differences (r=0.517, P=0.028. Conclusion: Based on the findings of the current study, the total fluid volume might have a more dominant effect on IOP peaks than the sympathetic system activity. Furthermore, the SBP was found to correlate with the IOP.

  2. High-Pressure Chemistry of a Zeolitic Imidazolate Framework Compound in the Presence of Different Fluids.

    Science.gov (United States)

    Im, Junhyuck; Yim, Narae; Kim, Jaheon; Vogt, Thomas; Lee, Yongjae

    2016-09-14

    Pressure-dependent structural and chemical changes of the zeolitic imidazolate framework compound ZIF-8 have been investigated using different pressure transmitting media (PTM) up to 4 GPa. The unit cell of ZIF-8 expands and contracts under hydrostatic pressure depending on the solvent molecules used as PTM. When pressurized in water up to 2.2(1) GPa, the unit cell of ZIF-8 reveals a gradual contraction. In contrast, when alcohols are used as PTM, the ZIF-8 unit cell volume initially expands by 1.2% up to 0.3(1) GPa in methanol, and by 1.7% up to 0.6(1) GPa in ethanol. Further pressure increase then leads to a discontinuous second volume expansion by 1.9% at 1.4(1) GPa in methanol and by 0.3% at 2.3(1) GPa in ethanol. The continuous uptake of molecules under pressure, modeled by the residual electron density derived from Rietveld refinements of X-ray powder diffraction, reveals a saturation pressure near 2 GPa. In non-penetrating PTM (silicone oil), ZIF-8 becomes amorphous at 0.9(1) GPa. The structural changes observed in the ZIF-8-PTM system under pressure point to distinct molecular interactions within the pores.

  3. Membrane distillation against a pressure difference

    NARCIS (Netherlands)

    Keulen, L.; Ham, L.V. van der; Kuipers, N.J.M.; Hanemaaijer, J.H.; Vlugt, T.J.H.; Kjelstrup, S.

    2017-01-01

    Membrane distillation is an attractive technology for production of fresh water from seawater. The MemPower® concept, studied in this work, uses available heat (86 °C) to produce pressurized water (2.2 bar and 46 °C) by membrane distillation, which again can be used to power a turbine for

  4. Location-dependent depth and undermining formation of pressure ulcers.

    Science.gov (United States)

    Takahashi, Yoshiko; Isogai, Zenzo; Mizokami, Fumihiro; Furuta, Katsunori; Nemoto, Tetsuya; Kanoh, Hiroyuki; Yoneda, Masahiko

    2013-08-01

    We examined the location-specific properties of pressure ulcers, focusing on depth and undermining formation, which are often unfavorable factors for ulcer healing. We conducted a retrospective observational study of 2 independent databases on pressure ulcers. Databases from a 200-bed hospital (database A) and a 300-bed hospital (database B) were collected during different time periods. Relationships between ulcer location, ulcer depth, and undermining formation were analyzed. All pressure ulcers were accurately diagnosed and classified according to their locations. A total of 282 pressure ulcers in 189 patients from database A and 232 pressure ulcers in 154 patients from database B were analyzed. It was found that pressure ulcers primarily developed over the sacrum. Ratio of stages III and IV pressure ulcers was high in pressure ulcers of the foot, ankle, and crus on the lower leg. Among the deep pressure ulcers, undermining formation was frequently observed on the greater trochanter, ilium, and sacrum. In contrast, pressure ulcers of the foot, ankle, and crus did not exhibit undermining formation. Our results revealed marked differences in pressure ulcer properties depending on their location. Factors affecting depth and undermining of pressure ulcers appear to be related to anatomical and physical properties of the bone and subcutaneous tissue. Copyright © 2013 Tissue Viability Society. Published by Elsevier Ltd. All rights reserved.

  5. Total hepatofugal portal blood flow in cirrhosis demonstrated by transhepatic portography

    International Nuclear Information System (INIS)

    Burcharth, F.; Aagaard, J.; Herlev Hospital

    1988-01-01

    We investigated 108 patients with cirrhosis of the liver and portal hypertension by percutaneous transhepatic portography to demonstrate the occurrence and frequency of total hepatofugal portal blood flow. Sixteen patients (14.8%) had a total hepatofugal portal blood flow. The aetiology of portal hypertension and the portal pressure did not differ from that in the group of patients with hepatopetal portal blood flow. A significantly higher percentage of patients in the group with hepatofugal flow had gastro-oesophageal varices (P [de

  6. Peripheral arterial volume distensibility: significant differences with age and blood pressure measured using an applied external pressure

    International Nuclear Information System (INIS)

    Zheng, Dingchang; Murray, Alan

    2011-01-01

    A new arterial distensibility measurement technique was assessed in 100 healthy normotensive subjects. Arterial transmural pressures on the whole right arm were reduced with a 50 cm long cuff inflated to 10, 20, 30 and 40 mmHg. The electrocardiogram, and finger and ear photoplethysmograms were recorded simultaneously. Arm pulse propagation time, pulse wave velocity (PWV) and arterial volume distensibility were determined. With a 40 mmHg reduction in transmural pressure, arm pulse propagation time increased from 61 to 83 ms, PWV decreased from 12 to 8 m s −1 and arterial distensibility increased from 0.102% to 0.232% per mmHg (all P < 0.0001). At all cuff pressures, arterial distensibility was significantly related to resting mean arterial pressure (MAP), diastolic blood pressure (DBP) and age, and for systolic blood pressure at 30 and 40 mmHg (all P < 0.05). At 40 mmHg cuff pressure, arterial distensibility fell by 54% for a MAP increase from 75 to 105 mmHg, 57% for a DBP increase from 60 to 90 mmHg and 47% for an age increase from 20 to 70 years. These changes were more than double than those without cuff pressure. Our technique showed that systemic volume distensibility of the peripheral arm artery reduced with age, with a greater effect at higher external and lower transmural pressures

  7. Membrane distillation against a pressure difference

    NARCIS (Netherlands)

    Keulen, L.; van der Ham, LV; Kuipers, N.J.M.; Hanemaaijer, J.H.; Vlugt, T.J.H.; Kjelstrup, S

    2017-01-01

    Membrane distillation is an attractive technology for production of fresh water from seawater. The MemPower®MemPower® concept, studied in this work, uses available heat (86 °C) to produce pressurized water (2.2 bar and 46 °C) by membrane distillation, which again can be used to power a turbine for

  8. Association of Inter-Arm Systolic Blood Pressure Difference with Coronary Atherosclerotic Disease Burden Using Calcium Scoring.

    Science.gov (United States)

    Her, Ae Young; Cho, Kyoung Im; Garg, Scot; Kim, Yong Hoon; Shin, Eun Seok

    2017-09-01

    There are no sufficient data on the correlation between inter-arm blood pressure (BP) difference and coronary atherosclerosis found using coronary artery calcium score (CACS). We aimed to investigate if the increased difference in inter-arm BP is independently associated with severity of CACS. Patients who had ≥3 cardiovascular risk factors or an intermediate Framingham Risk Score (FRS; ≥10) were enrolled. Inter-arm BP difference was defined as the absolute difference in BP in both arms. Quantitative CACS was measured by using coronary computed tomography angiography with the scoring system. A total of 261 patients were included in this study. Age (r=0.256, parm systolic BP (SBP; r=0.172, p=0.005), mean of left arm SBP (r=0.190, p=0.002), inter-arm SBP difference (r=0.152, p=0.014), and the FRS (r=0.278, parm SBP difference (≥6 mm Hg) was significantly associated with CACS ≥300 [odds ratio (OR) 2.17, 95% confidence interval (CI) 1.12-4.22; p=0.022]. In multivariable analysis, the inter-arm SBP difference ≥6 mm Hg was also significantly associated with CACS ≥300 after adjusting for clinical risk factors (OR 2.34, 95 % CI 1.06-5.19; p=0.036). An increased inter-arm SBP difference (≥6 mm Hg) is associated with coronary atherosclerotic disease burden using CACS, and provides additional information for predicting severe coronary calcification, compared to models based on traditional risk factors. © Copyright: Yonsei University College of Medicine 2017

  9. Age-specific differences between conventional and ambulatory daytime blood pressure values

    DEFF Research Database (Denmark)

    Conen, David; Aeschbacher, Stefanie; Thijs, Lutgarde

    2014-01-01

    Mean daytime ambulatory blood pressure (BP) values are considered to be lower than conventional BP values, but data on this relation among younger individuals ... population-based cohorts. We compared individual differences between daytime ambulatory and conventional BP according to 10-year age categories. Age-specific prevalences of white coat and masked hypertension were calculated. Among individuals aged 18 to 30, 30 to 40, and 40 to 50 years, mean daytime BP...

  10. Solid gas reaction phase diagram under high gas pressure

    International Nuclear Information System (INIS)

    Ishizaki, K.

    1992-01-01

    This paper reports that to evaluate which are the stable phases under high gas pressure conditions, a solid-gas reaction phase diagram under high gas pressure (HIP phase diagram) has been proposed by the author. The variables of the diagram are temperature, reactant gas partial pressure and total gas pressure. Up to the present time the diagrams have been constructed using isobaric conditions. In this work, the stable phases for a real HIP process were evaluated assuming an isochoric condition. To understand the effect of the total gas pressure on stability is of primary importance. Two possibilities were considered and evaluated, those are: the total gas pressure acts as an independent variable, or it only affects the fugacity values. The results of this work indicate that the total gas pressure acts as an independent variable, and in turn also affects the fugacity values

  11. Effect of high hydrostatic pressure on overall quality parameters of watermelon juice.

    Science.gov (United States)

    Liu, Y; Zhao, X Y; Zou, L; Hu, X S

    2013-06-01

    High hydrostatic pressure as a kind of non-thermal processing might maintain the quality of thermo-sensitive watermelon juice. So, the effect of high hydrostatic pressure treatment on enzymes and quality of watermelon juice was investigated. After high hydrostatic pressure treatment, the activities of polyphenol oxidase, peroxidase, and pectin methylesterase of juice decreased significantly with the pressure (P  0.05). No significant difference was observed in lycopene and total phenolics after high hydrostatic pressure treatment when compared to the control (P > 0.05). Cloudiness and viscosity increased with pressure (P  0.05). a*- and b*-value both unchanged after high hydrostatic pressure treatment (P > 0.05) while L*-value increased but the values had no significant difference among treated juices. Browning degree after high hydrostatic pressure treatment decreased with increase in pressure and treatment time (P hydrostatic pressure had little effect on color of juice. The results of this study demonstrated the efficacy of high hydrostatic pressure in inactivating enzymes and maintaining the quality of watermelon juice.

  12. Pressure transmission area and maximum pressure transmission of different thermoplastic resin denture base materials under impact load.

    Science.gov (United States)

    Nasution, Hubban; Kamonkhantikul, Krid; Arksornnukit, Mansuang; Takahashi, Hidekazu

    2018-01-01

    The purposes of the present study were to examine the pressure transmission area and maximum pressure transmission of thermoplastic resin denture base materials under an impact load, and to evaluate the modulus of elasticity and nanohardness of thermoplastic resin denture base. Three injection-molded thermoplastic resin denture base materials [polycarbonate (Basis PC), ethylene propylene (Duraflex), and polyamide (Valplast)] and one conventional heat-polymerized acrylic resin (PMMA, SR Triplex Hot) denture base, all with a mandibular first molar acrylic resin denture tooth set in were evaluated (n=6). Pressure transmission area and maximum pressure transmission of the specimens under an impact load were observed by using pressure-sensitive sheets. The modulus of elasticity and nanohardness of each denture base (n=10) were measured on 15×15×15×3mm 3 specimen by using an ultramicroindentation system. The pressure transmission area, modulus of elasticity, and nanohardness data were statistically analyzed with 1-way ANOVA, followed by Tamhane or Tukey HSD post hoc test (α=.05). The maximum pressure transmission data were statistically analyzed with Kruskal-Wallis H test, followed by Mann-Whitney U test (α=.05). Polymethyl methacrylate showed significantly larger pressure transmission area and higher maximum pressure transmission than the other groups (Pelasticity and nanohardness among the four types of denture bases (Pelasticity and nanohardness of each type of denture base were demonstrated. Copyright © 2017 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  13. Hydrostatic paradox: experimental verification of pressure equilibrium

    Science.gov (United States)

    Kodejška, Č.; Ganci, S.; Říha, J.; Sedláčková, H.

    2017-11-01

    This work is focused on the experimental verification of the balance between the atmospheric pressure acting on the sheet of paper, which encloses the cylinder completely or partially filled with water from below, where the hydrostatic pressure of the water column acts against the atmospheric pressure. First of all this paper solves a theoretical analysis of the problem, which is based, firstly, on the equation for isothermal process and, secondly, on the equality of pressures inside and outside the cylinder. From the measured values the confirmation of the theoretical quadratic dependence of the air pressure inside the cylinder on the level of the liquid in the cylinder is obtained, the maximum change in the volume of air within the cylinder occurs for the height of the water column L of one half of the total height of the vessel H. The measurements were made for different diameters of the cylinder and with plates made of different materials located at the bottom of the cylinder to prevent liquid from flowing out of the cylinder. The measured values were subjected to statistical analysis, which demonstrated the validity of the zero hypothesis, i.e. that the measured values are not statistically significantly different from the theoretically calculated ones at the statistical significance level α  =  0.05.

  14. Are there differences between partial and total periodontal examination of the mouth?

    Directory of Open Access Journals (Sweden)

    Renata S Coelho

    2017-09-01

    Full Text Available Background: Diagnosis of periodontal disease for epidemiologic survey is difficult due to complexity of periodontal exam. The aim of this study was  to compare data from a full-mouth examination and a partial-mouth examination, observing the agreement between both methods of presenting the Community Periodontal Index (CPI. Methods and Findings: The population comprised of male and female subjects, aged 18 years and over, attending public health centers in the city of Recife, Brazil. A total of 505 patients participated in this study. Each participant completed a form and underwent periodontal examination. Firstly, for each tooth present one of the periodontal conditions was determined: periodontal health, gingival bleeding, dental calculus, shallow periodontal pockets and deep periodontal pockets, according to CPI. Finally, partial data (10 index teeth was recorded derived from the total version of CPI. Bivariate analysis of frequencies and means was performed. Mc Nemar test was used to calculate the level of statistical significance of the association tested. There are significant statistical differences between partial and full-mouth examination (p<0.001. According to gender, men classified as score 1 presented the same prevalence in both methods; partial recording overestimated 0.2% of women classified as score 1; percentile difference among men was higher for subjects classified as score 0. Among subjects with at least one tooth with deep periodontal pocket, percentile difference between different approaches was higher among elders (60 years and over. Conclusions: Considering the variable age, the smaller amount of lost information refers to periodontal pockets in individuals aged 18 to 30 years of age. In older individuals classified as periodontally healthy and with gingival bleeding no loss of information was observed. Partial examination of the mouth underestimated the presence of periodontal pockets and overestimated the presence of

  15. Pressurized Thermal Shock Analysis for OPR1000 Pressure Vessel

    Energy Technology Data Exchange (ETDEWEB)

    Bhowmik, P. K.; Shamim, J. A.; Gairola, A.; Suh, Kune Y. [Seoul National Univ., Seoul (Korea, Republic of)

    2014-10-15

    The study provides a brief understanding of the analysis procedure and techniques using ANSYS, such as the acceptance criteria, selection and categorization of events, thermal analysis, structural analysis including fracture mechanics assessment, crack propagation and evaluation of material properties. PTS may result from instrumentation and control malfunction, inadvertent steam dump, and postulated accidents such as smallbreak (SB) LOCA, large-break (LB) LOCA, main steam line break (MSLB), feedwater line breaks and steam generator overfill. In this study our main focus is to consider only the LB LOCA due to a cold leg break of the Optimized Power Reactor 1000 MWe (OPR1000). Consideration is given as well to the emergency core cooling system (ECCS) specific sequence with the operating parameters like pressure, temperature and time sequences. The static structural and thermal analysis to investigate the effects of PTS on RPV is the main motivation of this study. Specific surface crack effects and its propagation is also considered to measure the integrity of the RPV. This study describes the procedure for pressurized thermal shock analysis due to a loss of coolant accidental condition and emergency core cooling system operation for reactor pressure vessel.. Different accidental events that cause pressurized thermal shock to nuclear RPV that can also be analyzed in the same way. Considering the limitations of low speed computer only the static analysis is conducted. The modified LBLOCA phases and simplified geometry can is utilized to analyze the effect of PTS on RPV for general understanding not for specific specialized purpose. However, by integrating the disciplines of thermal and structural analysis, and fracture mechanics analysis a clearer understanding of the total aspect of the PTS problem has resulted. By adopting the CFD, thermal hydraulics, uncertainties and risk analysis for different type of accidental conditions, events and sequences with proper

  16. Analysis of Pressure Fluctuations in a Prototype Pump-Turbine with Different Numbers of Runner Blades in Turbine Mode

    Directory of Open Access Journals (Sweden)

    Deyou Li

    2018-06-01

    Full Text Available In pump-turbines, high pressure fluctuation is one of the crucial instabilities, which is harmful to the stable and effective operation of the entire unit. Extensive studies have been carried out to investigate pressure fluctuations (amplitude and frequency at specific locations. However, limited research was conducted on the distribution of pressure fluctuations in turbine mode in a pump-turbine, as well as the influence of the number of runner blades on pressure fluctuations. Hence, in this study, three dimensional numerical simulations were performed to predict the distribution of pressure fluctuations with different numbers of runner blades in a prototype pump-turbine in turbine mode using the shear stress transport (SST k-ω turbulence model. Three operating points with the same hydraulic head and different mass flow rates were simulated. The distribution of pressure fluctuation components of blade passing frequency and its harmonics in the direction along the whole flow path, as well as along the circumferential direction, was presented. The mass flow rate and number of runner blades have great influence on the distribution of pressure fluctuations, especially at blade passing frequency along circumferential direction. The mass flow rate mainly affects the position of peak pressure fluctuations, while the number of runner blades mainly changes the number of peak pressure fluctuations. Additionally, the number of runner blades influences the dominant frequencies of pressure fluctuations especially in the spiral casing and draft tube.

  17. Effect of Different Solvents on Total Phenolic Contents and Antioxidant Activity of Zizyphus jujube Miller Fruits

    Directory of Open Access Journals (Sweden)

    Gholamhossein Davarynejad

    2017-10-01

    materials as well as the type of extractable compounds. The correct selection of solvent can improve the extraction yield of antioxidants from plants matrices considerably. For this reason, in the present study, some selected types of solvent showed different results. For extraction of total phenol and flavonoid compound, acetone 50% was the best yield. In methanolic extract (50, 100%, the highest amounts of anthocyanin and total tannin were reported. In all extracts, water had the least efficiency in comparison with other solvents. High correlation was observed in total phenolic content and antioxidant activity which was determined by DPPH and FRAP assay. Acetone 50% was the most potent for scavenging free radicals and reducing a ferric-tripyridyltriazine, Fe (III-TPTZ, complex to ferrous, Fe (II in all extracts. Conclusions: The results of the present study indicated that polarity, selectivity, viscosity, and vapor pressure are important physicochemical properties that should be considered when selecting a suitable solvent for the extraction of bioactive compounds from plant materials.

  18. Aging attenuates the interarm diastolic blood pressure difference induced by one-arm exercise.

    Science.gov (United States)

    Hu, Wei-tong; Li, Ju-xiang; Wang, Ji-wei; Xu, Jin-song; Yang, Qing; Geng, Yong-Jian; Su, Hai; Cheng, Xiao-shu

    2013-04-01

    It is known that one-arm exercise increases the interarm diastolic blood pressure difference (dIAD) in young individuals, but no research has been carried out in middle-aged and more senior populations. This study aimed to determine whether aging impacts the exercise-induced dIAD in healthy individuals. Normotensive adults (n=120) were recruited and divided into the young (22.5±1.5 years), middle-aged (42.8±4.6 years), and senior (61.0±7.0 years) groups. The right arm exercise involved performing cycling movements at 60 times/min for 3 min. Bilateral brachial blood pressures (BPs) were simultaneously measured using two automatic BP measurement devices before (baseline), immediately (0), 5, 10, and 15 min after the exercise. The difference in bilateral diastolic BPs was calculated as BP l-r and its absolute value of at least 10 mmHg was considered as IAD. At baseline, the systolic blood pressure (SBP) l-r and diastolic blood pressure (DBP) l-r were similar in three age groups. One-arm exercise induced a marked decrease in DBP in the exercised arm, and then increased the prevalence of DBP l-r and dIAD in the three age groups in an age-dependent manner. The prevalence of dIAD increased from the baseline of zero to 85% at 0 min in young, 37% in middle-aged, and 30% in senior groups. One-arm exercise did not significantly alter the prevalence of SBP l-r and systolic IAD in the three groups. A reverse correlation was found between the DBP l-r 0 and ages (r=-0.359, Parm exercise in healthy adults.

  19. Analysis of blood pressure signal in patients with different ventricular ejection fraction using linear and non-linear methods.

    Science.gov (United States)

    Arcentales, Andres; Rivera, Patricio; Caminal, Pere; Voss, Andreas; Bayes-Genis, Antonio; Giraldo, Beatriz F

    2016-08-01

    Changes in the left ventricle function produce alternans in the hemodynamic and electric behavior of the cardiovascular system. A total of 49 cardiomyopathy patients have been studied based on the blood pressure signal (BP), and were classified according to the left ventricular ejection fraction (LVEF) in low risk (LR: LVEF>35%, 17 patients) and high risk (HR: LVEF≤35, 32 patients) groups. We propose to characterize these patients using a linear and a nonlinear methods, based on the spectral estimation and the recurrence plot, respectively. From BP signal, we extracted each systolic time interval (STI), upward systolic slope (BPsl), and the difference between systolic and diastolic BP, defined as pulse pressure (PP). After, the best subset of parameters were obtained through the sequential feature selection (SFS) method. According to the results, the best classification was obtained using a combination of linear and nonlinear features from STI and PP parameters. For STI, the best combination was obtained considering the frequency peak and the diagonal structures of RP, with an area under the curve (AUC) of 79%. The same results were obtained when comparing PP values. Consequently, the use of combined linear and nonlinear parameters could improve the risk stratification of cardiomyopathy patients.

  20. Prevalence and implications of a difference in systolic blood pressure between one arm and the other in vascular surgical patients.

    Science.gov (United States)

    Durrand, J W; Batterham, A M; O'Neill, B R; Danjoux, G R

    2013-12-01

    Inter-arm differences in blood pressure may confound haemodynamic management in vascular surgery. We evaluated 898 patients in the vascular pre-assessment clinic to determine the prevalence of inter-arm differences in systolic and mean arterial pressure, quantify the consequent risk of clinical error in siting monitoring peri-operatively and evaluate systolic inter-arm difference as a predictor of all-cause mortality (median follow-up 49 months). The prevalence of a systolic inter-arm difference ≥ 15 mmHg was 26% (95% CI 23-29%). The prevalence of an inter-arm mean arterial pressure difference ≥ 10 mmHg was 26% (95% CI 23-29%) and 11% (95% CI 9-13%) for a difference ≥ 15 mmHg. Monitoring could be erroneously sited in an arm reading lower for systolic pressure once in every seven to nine patients. The hazard ratio for a systolic inter-arm difference ≥ 15 mmHg vs arm blood pressure differences are common in this population, with a high potential for monitoring errors. Systolic inter-arm difference was not associated with medium-term mortality. [Correction added on 17 October 2013, after first online publication: In the Summary the sentence beginning 'We evaluated 898 patients' was corrected from (median (IQR [range]) follow-up 49 months) to read (median follow up 49 months)]. © 2013 The Association of Anaesthetists of Great Britain and Ireland.

  1. Antioxidant capacity and total polyphenol content in different apple varieties cultivated in Chile

    OpenAIRE

    Quitral, Vilma; Sepulveda, Marcela; Schwartz, Marco; Kern, Werther

    2014-01-01

    Three apple varieties cultivated in Chile were studied in total polyphenol content by Folin Ciocalteu method and antioxidant capacity by FRAP method: Granny Smith, Royal Gala and Fuji (whole and peeled apples). The total polyphenol content in whole and peeled apples do not show significant differences. The antioxidant capacity of the Granny Smith variety is significantly higher than Royal Gala and Fuji. Apple dehydration at 60 oC for 4 hours to obtain flakes keeps polyphenol content high. The...

  2. Age- and Functional Status-Dependent Association Between Blood Pressure and Cognition

    DEFF Research Database (Denmark)

    Ogliari, Giulia; Sabayan, Behnam; Mari, Daniela

    2015-01-01

    OBJECTIVES: To evaluate whether the relationship between blood pressure (BP) measures and cognitive function is different according to age and functional status in older outpatients. DESIGN: Cross-sectional. SETTING: Outpatient hospital-based Milan Geriatrics 75+ Cohort Study. PARTICIPANTS......: Individuals aged 75 and older (N = 1,540). MEASUREMENTS: Blood pressure, Mini-Mental State Examination (MMSE), basic activities of daily living (ADLs), and instrumental activities of daily living (IADLs) were assessed. Associations between BP measures and MMSE score were first analyzed in the total population...... using linear regression models and were then further examined according to strata of age, ADLs, and IADLs. All analyses were adjusted for sociodemographic factors and presence of comorbidities. RESULTS: In the total population, higher systolic BP (SBP), diastolic BP (DBP), pulse pressure (PP), and mean...

  3. ZnO nanorod arrays grown under different pressures and their photoluminescence properties

    Energy Technology Data Exchange (ETDEWEB)

    Meng Xiuqing [Key Laboratory of Excited State Processes, Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, 16 East Nan-Hu Road, Open Economic ZoneChangchun 130033 (China); Graduate School of the Chinese Academy of Sciences (China); Zhao Dongxu [Key Laboratory of Excited State Processes, Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, 16 East Nan-Hu Road, Open Economic ZoneChangchun 130033 (China)]. E-mail: dxzhao2000@yahoo.com.cn; Shen Dezhen [Key Laboratory of Excited State Processes, Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, 16 East Nan-Hu Road, Open Economic ZoneChangchun 130033 (China); Zhang Jiying [Key Laboratory of Excited State Processes, Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, 16 East Nan-Hu Road, Open Economic ZoneChangchun 130033 (China); Li Binghui [Key Laboratory of Excited State Processes, Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, 16 East Nan-Hu Road, Open Economic ZoneChangchun 130033 (China); Wang Xiaohua [National Key Laboratory of High Power Semiconductor Laser, Changchun University of Science and technology, 7089 Weixing Road Changchun (China); Fan Xiwu [Key Laboratory of Excited State Processes, Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, 16 East Nan-Hu Road, Open Economic ZoneChangchun 130033 (China)

    2007-01-15

    The ZnO nanorod arrays were synthesized via a simple vapor deposition method on Si (1 1 1) substrates at a low growth temperature of 520 deg. C. By selecting different source materials under different growth pressures, well-aligned hexagonal-shaped ZnO nanorod arrays were obtained under both conditions. X-ray diffraction (XRD) analysis confirmed the nanorods are c-axis orientated. Selected area electron diffraction (SAED) and transmission electron microscopy (TEM) analysis demonstrated the individual nanorod is single crystal. Photoluminescence (PL) analyses show the superior optical properties of the nanorod arrays.

  4. ZnO nanorod arrays grown under different pressures and their photoluminescence properties

    International Nuclear Information System (INIS)

    Meng Xiuqing; Zhao Dongxu; Shen Dezhen; Zhang Jiying; Li Binghui; Wang Xiaohua; Fan Xiwu

    2007-01-01

    The ZnO nanorod arrays were synthesized via a simple vapor deposition method on Si (1 1 1) substrates at a low growth temperature of 520 deg. C. By selecting different source materials under different growth pressures, well-aligned hexagonal-shaped ZnO nanorod arrays were obtained under both conditions. X-ray diffraction (XRD) analysis confirmed the nanorods are c-axis orientated. Selected area electron diffraction (SAED) and transmission electron microscopy (TEM) analysis demonstrated the individual nanorod is single crystal. Photoluminescence (PL) analyses show the superior optical properties of the nanorod arrays

  5. Mean intraocular pressure in hypertensive adults

    International Nuclear Information System (INIS)

    Irum, S.; Malik, A.M.; Saeed, M.

    2015-01-01

    To determine the mean Intraocular Pressure (IOP) in already diagnosed adult hypertensive patients with different grades of hypertension. Study Design: Cross-sectional descriptive study. Place and Duration of Study: Combined Military Hospital, Lahore, from March 2012 to Aug 2012. Patients and Methods: A total of 178 already diagnosed hypertensive patients were selected. A detailed history of ocular or systemic diseases was taken. Intraocular pressure was measured with help of Goldmann applanation tonometer. Three consecutive readings of IOP of each eye were taken at 30 minutes interval and mean calculated. Blood pressure was recorded in seated position from right upper arm, by mercury sphygmomanometer. Blood pressure measurements were determined by taking the mean value of three systolic and diastolic readings. Results: The results of intraocular pressure (IOP) between various grades of hypertension were determined. There was an increase in mean IOP with rise in blood pressure. The subjects with grade I hypertension showed a mean IOP of 13.95 ± 3.74 mmHg, while grade II and grade III hypertensive subjects had mean IOPs as 18.10 ± 3.32 and 20.21 ± 2.52 mmHg respectively. Conclusion: A higher value of mean IOP was found with increase in systolic and diastolic blood pressures. (author)

  6. The effect of different depths of medial heel skive on plantar pressures

    Directory of Open Access Journals (Sweden)

    Bonanno Daniel R

    2012-08-01

    Full Text Available Abstract Background Foot orthoses are often used to treat lower limb injuries associated with excessive pronation. There are many orthotic modifications available for this purpose, with one being the medial heel skive. However, empirical evidence for the mechanical effects of the medial heel skive modification is limited. This study aimed to evaluate the effect that different depths of medial heel skive have on plantar pressures. Methods Thirty healthy adults (mean age 24 years, range 18–46 with a flat-arched or pronated foot posture and no current foot pain or deformity participated in this study. Using the in-shoe pedar-X® system, plantar pressure data were collected for the rearfoot, midfoot and forefoot while participants walked along an 8 metre walkway wearing a standardised shoe. Experimental conditions included a customised foot orthosis with the following 4 orthotic modifications: (i no medial heel skive, (ii a 2 mm medial heel skive, (iii a 4 mm medial heel skive and (iv a 6 mm medial heel skive. Results Compared to the foot orthosis with no medial heel skive, statistically significant increases in peak pressure were observed at the medial rearfoot – there was a 15% increase (p = 0.001 with the 4 mm skive and a 29% increase (p  Conclusions This study found that a medial heel skive of 4 mm or 6 mm increases peak pressure under the medial rearfoot in asymptomatic adults with a flat-arched or pronated foot posture. Plantar pressures at the midfoot and forefoot were not altered by a medial heel skive of 2, 4 or 6 mm. These findings provide some evidence for the effects of the medial heel skive orthotic modification.

  7. Interarm blood pressure difference in people with diabetes: measurement and vascular and mortality implications: a cohort study.

    Science.gov (United States)

    Clark, Christopher E; Steele, Anna M; Taylor, Rod S; Shore, Angela C; Ukoumunne, Obioha C; Campbell, John L

    2014-06-01

    Differences in blood pressure between arms are associated with vascular disease and increased mortality; this has not been reported in diabetes. We explored these associations, and assessed reference standard and pragmatic measurement techniques, in people with diabetes and in nondiabetic controls. A prospective cohort study in Devon, England, recruited 727 people with type 1 or type 2 diabetes and 285 nondiabetic controls. Simultaneous repeated measurements of bilateral blood pressure were made at recruitment. Data were used to inform a pragmatic measurement strategy. Interarm differences were examined for cross-sectional associations with target organ disease and prospective mortality associations (median follow-up 52 months). We found 8.6% of participants with diabetes and 2.9% of controls had systolic interarm differences ≥10 mmHg. Single pairs of blood pressure measurements had high negative predictive values (97-99%) for excluding interarm differences. Systolic interarm differences ≥10 mmHg in diabetes were associated with peripheral arterial disease (odds ratio [OR] 3.4 [95% CI 1.2-9.3]). Differences ≥15 mmHg were associated with diabetic retinopathy (OR 5.7 [1.5-21.6]) and chronic kidney disease (OR 7.0 [1.7-29.8]). Systolic interarm differences were associated prospectively with increased cardiovascular mortality: hazard ratios 3.5 (1.0-13.0) for ≥10 mmHg and 9.0 (2.0-41.0) for ≥15 mmHg. Blood pressure should be measured in both arms during initial assessment in diabetes. Systolic interarm differences can be excluded with a single pair of measurements. In the population with diabetes, systolic differences may be associated with an increased risk of morbidity and mortality. © 2014 by the American Diabetes Association.

  8. Primary break with total loss of high pressure safety injection

    International Nuclear Information System (INIS)

    Cordelle, F.; Champ, M.; Pochard, R.

    1988-10-01

    The probabilitic safety assessment of a 900 MW plant has displayed the potential importance, with regard to the risk, of intermediate primary breaks with failure of the high pressure safety injection system. The probability of such sequence is about 10 -6 /plant X year. Therefore, it is necessary to establish: - if this sequence can lead to core melt down, - if clad ruptures can occur. This event must be taken into account to determine the repair time of contaminated systems. For these studies, a three inch equivalent diameter break is considerd, as this is the most sensitive in its category with regard to these phenomena. In addition to the above objectives, the purpose of these studies is to evaluate the sensitivity of the results to the following parameters: - the time limit at which the operator starts cooling down the plant via the steam generators. Two calculations have been made with the RELAP code (1 and 2) and two with the CATHARE code (3 and 4) - the pump trip time. Four calculations have been made with the CATHARE code (5, 6, 7 and 8). In the case of failure of only one high pressure safety injection file, 6 calculations have been made with the CATHARE code, concerning the influence of pump trip time (9, 10, 11, 12, 13 and 14)

  9. Comparison of different screening methods for blood pressure disorders in children and adolescents

    Directory of Open Access Journals (Sweden)

    Felipe Alves Mourato

    2015-06-01

    Full Text Available OBJECTIVE: To compare different methods of screening for blood pressure disorders in children and adolescents. METHOD: A database with 17,083 medical records of patients from a pediatric cardiology clinic was used. After analyzing the inclusion and exclusion criteria, 5,650 were selected. These were divided into two age groups: between 5 and 13 years and between 13 and 18 years. The blood pressure measurement was classified as normal, pre-hypertensive, or hypertensive, consistent with recent guidelines and the selected screening methods. Sensitivity, specificity, and accuracy were then calculated according to gender and age range. RESULTS: The formulas proposed by Somu and Ardissino's table showed low sensitivity in identifying pre-hypertension in all age groups, whereas the table proposed by Kaelber showed the best results. The ratio between blood pressure and height showed low specificity in the younger age group, but showed good performance in adolescents. CONCLUSION: Screening tools used for the assessment of blood pressure disorders in children and adolescents may be useful to decrease the current rate of underdiagnosis of this condition. The table proposed by Kaelber showed the best results; however, the ratio between BP and height demonstrated specific advantages, as it does not require tables.

  10. Comparison of different screening methods for blood pressure disorders in children and adolescents.

    Science.gov (United States)

    Mourato, Felipe Alves; Lima Filho, José Luiz; Mattos, Sandra da Silva

    2015-01-01

    To compare different methods of screening for blood pressure disorders in children and adolescents. A database with 17,083 medical records of patients from a pediatric cardiology clinic was used. After analyzing the inclusion and exclusion criteria, 5,650 were selected. These were divided into two age groups: between 5 and 13 years and between 13 and 18 years. The blood pressure measurement was classified as normal, pre-hypertensive, or hypertensive, consistent with recent guidelines and the selected screening methods. Sensitivity, specificity, and accuracy were then calculated according to gender and age range. The formulas proposed by Somu and Ardissino's table showed low sensitivity in identifying pre-hypertension in all age groups, whereas the table proposed by Kaelber showed the best results. The ratio between blood pressure and height showed low specificity in the younger age group, but showed good performance in adolescents. Screening tools used for the assessment of blood pressure disorders in children and adolescents may be useful to decrease the current rate of underdiagnosis of this condition. The table proposed by Kaelber showed the best results; however, the ratio between BP and height demonstrated specific advantages, as it does not require tables. Copyright © 2014 Sociedade Brasileira de Pediatria. Published by Elsevier Editora Ltda. All rights reserved.

  11. Electrocardiographic, echocardiographic, and indirect blood pressure evaluation in dogs subjected to different sedation protocols

    Directory of Open Access Journals (Sweden)

    Helena Mondardo Cardoso

    Full Text Available ABSTRACT: The present study aimed to evaluate the effects of different sedation protocols on blood pressure and echocardiographic and electrocardiographic parameters in dogs. In total, 24 male mixed-breed dogs with a mean weight of 9.87±3.0kg were used.Animals were randomly divided into four groups (n=6, which were subjected to sedation using the following protocols: acepromazine (0.05mgkg-1 and butorphanol (0.3mgkg-1 (AB; acepromazine (0.05mgkg-1and methadone (0.5mgkg-1 (AM; acepromazine (0.03mgkg-1, methadone (0.5mgkg-1, and midazolam (0.3mgkg-1(MAM; and methadone only (0.5mgkg-1 (M. Indirect blood pressure (BP measurements and computerized electrocardiography (ECG and echocardiography (ECO were performed immediately before the application of the sedation protocol (baseline, and the same evaluations were repeated after 15 minutes. BP decreased in groups AB, MAM, and AM compared to baseline values. Electrocardiographic measurements showed decreased heart rates (HRs after sedation in all groups, and bradycardia was observed after sedation in two dogs from group M and one animal from group AM. The P-wave duration increased after sedation in groups AM and M. After sedation, no changes in cardiac dimensions were revealed byECO.Fractional shortening (FS decreased after sedation in the AM group, and dogs from group AB exhibited a smaller decrease in FS compared with the other groups. The cardiac index (CI was lower in groups AM and M than in the other groups. Animals from group AB were less resistant to examination and exhibited the most favorable sedation scores. It was concluded that the combination of acepromazine and butorphanol was the best sedation protocol for performing echocardiogram measurementsbecause dogs were less resistant to examinations and echocardiographic parameters of FS and CI remained stable.

  12. Diastolic Pressure Difference to Classify Pulmonary Hypertension in the Assessment of Heart Transplant Candidates.

    Science.gov (United States)

    Wright, Stephen P; Moayedi, Yasbanoo; Foroutan, Farid; Agarwal, Suhail; Paradero, Geraldine; Alba, Ana C; Baumwol, Jay; Mak, Susanna

    2017-09-01

    The diastolic pressure difference (DPD) is recommended to differentiate between isolated postcapillary and combined pre-/postcapillary pulmonary hypertension (Cpc-PH) in left heart disease (PH-LHD). However, in usual practice, negative DPD values are commonly calculated, potentially related to the use of mean pulmonary artery wedge pressure (PAWP). We used the ECG to gate late-diastolic PAWP measurements. We examined the method's impact on calculated DPD, PH-LHD subclassification, hemodynamic profiles, and mortality. We studied patients with advanced heart failure undergoing right heart catheterization to assess cardiac transplantation candidacy (N=141). Pressure tracings were analyzed offline over 8 to 10 beat intervals. Diastolic pulmonary artery pressure and mean PAWP were measured to calculate the DPD as per usual practice (diastolic pulmonary artery pressure-mean PAWP). Within the same intervals, PAWP was measured gated to the ECG QRS complex to calculate the QRS-gated DPD (diastolic pulmonary artery pressure-QRS-gated PAWP). Outcomes occurring within 1 year were collected retrospectively from chart review. Overall, 72 of 141 cases demonstrated PH-LHD. Within PH-LHD, the QRS-gated DPD yielded higher calculated DPD values (3 [-1 to 6] versus 0 [-4 to 3] mm Hg; P pulmonary hypertension ( P pulmonary hypertension. The QRS-gated DPD reclassifies a subset of PH-LHD patients from isolated postcapillary pulmonary hypertension to Cpc-PH, which is characterized by an adverse hemodynamic profile. © 2017 American Heart Association, Inc.

  13. Sewage sludge solubilization by high-pressure homogenization.

    Science.gov (United States)

    Zhang, Yuxuan; Zhang, Panyue; Guo, Jianbin; Ma, Weifang; Fang, Wei; Ma, Boqiang; Xu, Xiangzhe

    2013-01-01

    The behavior of sludge solubilization using high-pressure homogenization (HPH) treatment was examined by investigating the sludge solid reduction and organics solubilization. The sludge volatile suspended solids (VSS) decreased from 10.58 to 6.67 g/L for the sludge sample with a total solids content (TS) of 1.49% after HPH treatment at a homogenization pressure of 80 MPa with four homogenization cycles; total suspended solids (TSS) correspondingly decreased from 14.26 to 9.91 g/L. About 86.15% of the TSS reduction was attributed to the VSS reduction. The increase of homogenization pressure from 20 to 80 MPa or homogenization cycle number from 1 to 4 was favorable to the sludge organics solubilization, and the protein and polysaccharide solubilization linearly increased with the soluble chemical oxygen demand (SCOD) solubilization. More proteins were solubilized than polysaccharides. The linear relationship between SCOD solubilization and VSS reduction had no significant change under different homogenization pressures, homogenization cycles and sludge solid contents. The SCOD of 1.65 g/L was solubilized for the VSS reduction of 1.00 g/L for the three experimental sludge samples with a TS of 1.00, 1.49 and 2.48% under all HPH operating conditions. The energy efficiency results showed that the HPH treatment at a homogenization pressure of 30 MPa with a single homogenization cycle for the sludge sample with a TS of 2.48% was the most energy efficient.

  14. Association of serum total antioxidant capacity and total oxidant status with pain perception in patients with myofacial pain dysfunction.

    Science.gov (United States)

    Etoz, Osman A; Ataoglu, Hanife; Erel, Ozcan; Celik, Hakim; Herken, Emine Nur; Bayazit, Yildirim Ahmet

    2009-01-01

    We aimed to find out the association of total antioxidant capacity (TAC) and total oxidant status (TOS) with generalized pressure pain thresholds (PPT) of patients with myofacial pain dysfunction (MPD). PPT scores of patients with MPD (n = 37) and healthy individuals (n = 43) were measured on the hypothenar region of the hand using a mechanical algometer. Serum samples were collected and TAC and TOS were measured by novel methods. The TAC of patients was significantly lower than that of the control subjects. The difference between the TOS measurements of patients and control subjects was not significant. The PPT scores of the patients were significantly lower than that of control subjects. There may be an association between serum antioxidant capacity and MPD. Low serum TAC might also be related with pain perception.

  15. Measuring total health inequality: adding individual variation to group-level differences

    Directory of Open Access Journals (Sweden)

    Gakidou Emmanuela

    2002-08-01

    Full Text Available Abstract Background Studies have revealed large variations in average health status across social, economic, and other groups. No study exists on the distribution of the risk of ill-health across individuals, either within groups or across all people in a society, and as such a crucial piece of total health inequality has been overlooked. Some of the reason for this neglect has been that the risk of death, which forms the basis for most measures, is impossible to observe directly and difficult to estimate. Methods We develop a measure of total health inequality – encompassing all inequalities among people in a society, including variation between and within groups – by adapting a beta-binomial regression model. We apply it to children under age two in 50 low- and middle-income countries. Our method has been adopted by the World Health Organization and is being implemented in surveys around the world; preliminary estimates have appeared in the World Health Report (2000. Results Countries with similar average child mortality differ considerably in total health inequality. Liberia and Mozambique have the largest inequalities in child survival, while Colombia, the Philippines and Kazakhstan have the lowest levels among the countries measured. Conclusions Total health inequality estimates should be routinely reported alongside average levels of health in populations and groups, as they reveal important policy-related information not otherwise knowable. This approach enables meaningful comparisons of inequality across countries and future analyses of the determinants of inequality.

  16. Role of different negative pressure values in the process of infected wounds treated by vacuum-assisted closure: an experimental study.

    Science.gov (United States)

    Zhou, Min; Yu, Aixi; Wu, Gang; Xia, Chengyan; Hu, Xiang; Qi, Baiwen

    2013-10-01

    Vacuum-assisted closure (VAC) device is widely used to treat infected wounds in clinical work. Although the effect of VAC with different negative pressure values is well established, whether different negative pressures could result in varying modulation of wound relative cytokines was not clear. We hypothesise that instead of the highest negative pressure value the suitable value for VAC is the one which is the most effective on regulating wound relative cytokines. Infected wounds created on pigs' back were used to investigate the effects of varying negative pressure values of VAC devices. Wounds were treated with VAC of different negative pressure values or moist gauze, which was set as control. The VAC foam, semiocclusive dresses and moist gauze were changed on days 3, 5, 7 and 9 after wounds were created. When changing dressings, tissues from wounds were harvested for bacteria count and histology examination including Masson's trichrome stain and immunohistochemistry for microvessels. Western blot was carried out to test the expression of vascular endothelial growth factor (VEGF) and basic fibroblast growth factor (bFGF). Results showed that on days 3 and 5 the number of bacteria in wounds treated by VAC with 75, 150, 225 and 300 mmHg was significantly decreased compared with that in wounds treated by gauze and 0 mmHg pressure value. However, there was no difference in wounds treated with negative pressure values of 75 , 150, 225 and 300 mmHg at any time spot. Immunohistochemistry showed that more microvessels were generated in wounds treated by VAC using 75 and 150 mmHg negative pressure comparing with that using 225 and 300 mmHg on days 3 and 5. However this difference vanished on days 7 and 9. Morphological evaluation by Masson's trichrome staining showed increased collagen deposition in VAC of 75 and 150 mmHg compared with that in VAC of 225 and 300 mmHg. Western blot showed that the expression of VEGF and bFGF significantly increased when the wounds

  17. Experimental research of pressure drop in packed beds of monosized spheres a novel correlation for pressure drop calculation

    Directory of Open Access Journals (Sweden)

    Stamenić Mirjana S.

    2017-01-01

    Full Text Available Flow through packed beds of spheres is a complex phenomenon and it has been extensively studied. Although, there is many different correlations there is still no reliable universal equation for prediction of pressure drop. The paper presents the results of experimental research of pressure drop in packed bed of monosized spheres of three different diameters, 8, 11, and 13 mm set within cylindrical vessel of diameter dk = 74 mm, and two different heights of packed bed, hs = 300 and 400 mm. It has been proposed modification of widely used Ergun’s equation in the form of fp = [150+1.3•(Rep/(1-ε]•(1-ε2/(ε3×Rep and new correlation fp = 1/[(27.4-25700•dh/Rep+0.545+6.85•dh] for pressure drop calculation in simple and convenient form for hand and computer calculations. For total number of 362 experimental runs the correlation ratio of the modified Ergun’s relation was CR = 99.3%, and standard deviation SD = 12.2%, while novel relation has CR = 93.7% and SD = 5.4%. [Project of the Serbian Ministry of Education, Science and Technological Development, Grant no. 33049

  18. Association between body size and blood pressure in children from different ethnic origins

    NARCIS (Netherlands)

    LA de Hoog, Marieke; van Eijsden, Manon; Stronks, Karien; Gemke, Reinoud J. B. J.; Vrijkotte, Tanja G. M.

    2012-01-01

    Objective: To assess associations between body size and blood pressure in children (5-6 years) from different ethnic origins. Method: Five ethnic groups of the ABCD cohort were examined: Dutch (n=1 923), Turkish (n=99), Moroccan (n=187), Black-African (n=67) and Black-Caribbean (n=121). Data on

  19. Electronic structure and optical properties of AIN under high pressure

    International Nuclear Information System (INIS)

    Li Zetao; Dang Suihu; Li Chunxia

    2011-01-01

    We have calculated the electronic structure and optical properties of Wurtzite structure AIN under different high pressure with generalized gradient approximation (GGA) in this paper. The total energy, density of state, energy band structure and optical absorption and reflection properties under high pressure are calculated. By comparing the changes of the energy band structure, we obtained AIN phase transition pressure for 16.7 GPa, which is a direct band structure transforming to an indirect band structure. Meanwhile, according to the density of states distribution and energy band structure, we analyzed the optical properties of AIN under high-pressure, the results showed that the absorption spectra moved from low-energy to high-energy. (authors)

  20. Beat-by-beat analysis of cardiac output and blood pressure responses to short-term barostimulation in different body positions

    Science.gov (United States)

    Hildebrandt, Wulf; Schütze, Harald; Stegemann, J.

    Rapid quantification of the human baro-reflex control of heart rate has been achieved on a beat-by-beat basis using a neck-chamber with quick ECG-triggered pressure changes. Referring to recent findings on heart rate and stroke volume, the present study uses this technique to compare cardiac output as well as blood pressure changes in supine and upright position to investigate feedback effects and to confirm postural reflex modifications not revealed by RR-interval changes. A suction profile starting at +40 mmHg and running 7 steps of pressure decrease down to -65 mmHg was examined in 0° and 90° tilting position while beat-by-beat recordings were done of heart rate, stroke volume (impedance-cardiography) and blood pressure (Finapres tm) (n=16). The percentual heart rate decrease failed to be significantly different between positions. A suction-induced stroke volume increase led to a cardiac output almost maintained when supine and significantly increased when upright. A decrease in all blood pressure values was found during suction, except for systolic values in upright position which increased. Conclusively, (a) it is confirmed that different inotropy accounts for the seen gravitational effect on the cardiac output not represented by heart rate; (b) identical suction levels in different positions lead to different stimuli at the carotid receptor. This interference has to be considered in microgravity studies by beat-by-beat measurement of cardiac output and blood pressure.

  1. A Common Allele in FGF21 Associated with Sugar Intake Is Associated with Body Shape, Lower Total Body-Fat Percentage, and Higher Blood Pressure

    Directory of Open Access Journals (Sweden)

    Timothy M. Frayling

    2018-04-01

    Full Text Available Summary: Fibroblast growth factor 21 (FGF21 is a hormone that has insulin-sensitizing properties. Some trials of FGF21 analogs show weight loss and lipid-lowering effects. Recent studies have shown that a common allele in the FGF21 gene alters the balance of macronutrients consumed, but there was little evidence of an effect on metabolic traits. We studied a common FGF21 allele (A:rs838133 in 451,099 people from the UK Biobank study, aiming to use the human allele to inform potential adverse and beneficial effects of targeting FGF21. We replicated the association between the A allele and higher percentage carbohydrate intake. We then showed that this allele is more strongly associated with higher blood pressure and waist-hip ratio, despite an association with lower total body-fat percentage, than it is with BMI or type 2 diabetes. These human phenotypes of variation in the FGF21 gene will inform research into FGF21’s mechanisms and therapeutic potential. : Drugs targeting the hormone FGF21 may have beneficial health effects. Variations in human DNA in the FGF21 gene provide an indication of what those effects may be. Here, we show that variation in the FGF21 gene is associated with higher blood pressure and altered body shape, despite lower total body-fat percentage. Keywords: FGF21, BMI, waist-hip ratio, blood pressure, body fat, allele, genetic variant, UK Biobank

  2. Impact of pH and Total Soluble Solids on Enzyme Inactivation Kinetics during High Pressure Processing of Mango (Mangifera indica) Pulp.

    Science.gov (United States)

    Kaushik, Neelima; Nadella, Tejaswi; Rao, P Srinivasa

    2015-11-01

    This study was undertaken with an aim to enhance the enzyme inactivation during high pressure processing (HPP) with pH and total soluble solids (TSS) as additional hurdles. Impact of mango pulp pH (3.5, 4.0, 4.5) and TSS (15, 20, 25 °Brix) variations on the inactivation of pectin methylesterase (PME), polyphenol oxidase (PPO), and peroxidase (POD) enzymes were studied during HPP at 400 to 600 MPa pressure (P), 40 to 70 °C temperature (T), and 6- to 20-min pressure-hold time (t). The enzyme inactivation (%) was modeled using second order polynomial equations with a good fit that revealed that all the enzymes were significantly affected by HPP. Response surface and contour models predicted the kinetic behavior of mango pulp enzymes adequately as indicated by the small error between predicted and experimental data. The predicted kinetics indicated that for a fixed P and T, higher pulse pressure effect and increased isobaric inactivation rates were possible at lower levels of pH and TSS. In contrast, at a fixed pH or TSS level, an increase in P or T led to enhanced inactivation rates, irrespective of the type of enzyme. PPO and POD were found to have similar barosensitivity, whereas PME was found to be most resistant to HPP. Furthermore, simultaneous variation in pH and TSS levels of mango pulp resulted in higher enzyme inactivation at lower pH and TSS during HPP, where the effect of pH was found to be predominant than TSS within the experimental domain. Exploration of additional hurdles such as pH, TSS, and temperature for enzyme inactivation during high pressure processing of fruits is useful from industrial point of view, as these parameters play key role in preservation process design. © 2015 Institute of Food Technologists®

  3. Determinants of systemic zero-flow arterial pressure.

    Science.gov (United States)

    Brunner, M J; Greene, A S; Sagawa, K; Shoukas, A A

    1983-09-01

    Thirteen pentobarbital-anesthetized dogs whose carotid sinuses were isolated and perfused at a constant pressure were placed on total cardiac bypass. With systemic venous pressure held at 0 mmHg (condition 1), arterial inflow was stopped for 20 s at intrasinus pressures of 50, 125, and 200 mmHg. Zero-flow arterial pressures under condition 1 were 16.2 +/- 1.3 (SE), 13.8 +/- 1.1, and 12.5 +/- 0.8 mmHg, respectively. In condition 2, the venous outflow tube was clamped at the instant of stopping the inflow, causing venous pressure to rise. The zero-flow arterial pressures were 19.7 +/- 1.3, 18.5 +/- 1.4, and 16.4 +/- 1.2 mmHg for intrasinus pressures of 50, 125, and 200 mmHg, respectively. At all levels of intrasinus pressure, the zero-flow arterial pressure in condition 2 was higher (P less than 0.005) than in condition 1. In seven dogs, at an intrasinus pressure of 125 mmHg, epinephrine increased the zero-flow arterial pressure by 3.0 mmHg, whereas hexamethonium and papaverine decreased the zero-flow arterial pressure by 2 mmHg. Reductions in the hematocrit from 52 to 11% resulted in statistically significant changes (P less than 0.01) in zero-flow arterial pressures. Thus zero-flow arterial pressure was found to be affected by changes in venous pressure, hematocrit, and vasomotor tone. The evidence does not support the literally interpreted concept of the vascular waterfall as the model for the finite arteriovenous pressure difference at zero flow.

  4. Prevalence of dyslipidemia in normoglycemic subjects with newly diagnosed high blood pressure in Abuja, Nigeria.

    Science.gov (United States)

    Ojji, Dike B; Ajayi, Samuel O; Mamven, Manmak H; Atherton, John

    2009-02-01

    High blood pressure and dyslipidemia additively increases the risk of cardiovascular disease. There is a high prevalence of high blood pressure in Nigeria, but there are little data regarding the prevalence of dyslipidemia in subjects with high blood pressure. In this observational prospective study, we examined the prevalence of dyslipidemia in newly diagnosed normoglycemic subjects with high blood pressure. A total of 171 subjects presenting with high blood pressure for the first time in the cardiology and nephrology clinics at the University of Abuja Teaching Hospital were studied. Height, weight, and blood pressure were measured. Total cholesterol, low-density lipoprotein cholesterol (LDL-C), and high-density lipoprotein cholesterol (HDL-C) were determined in fasting plasma. The total cholesterol/HDL-C and non-HDL-C values were calculated. These measures were then classified according to the 2001 report of the National Cholesterol Education Program (NCEP) Expert Panel on Detection, Evaluation and Treatment of High Blood Cholesterol in Adults. Of the 171 subjects studied, 84 (49%) were male and 87 (51%) were female. Low HDL-C was present in 71 (45.8%), elevated LDL-C in 29 (17%), elevated total cholesterol in 19 (11.1%), and elevated triglyceride in 13 (7.6%), whereas eight (4.7%) of the study population had combined elevated total cholesterol and triglyceride. Female subjects had higher total cholesterol and lower HDL-C than male subjects, but these differences were not statistically significant. Obese subjects, compared to the nonobese, had significantly higher LDL-C and total cholesterol/HDL-C ratios in males and significantly higher triglyceride levels in females. Given the prevalence of dyslipidemia seen in this study, we suggest that fasting lipid measurements should be performed in all Nigerians with high blood pressure. These data suggest the need for health education and lifestyle modifications in hypertensive Nigerians to reduce both types of risk

  5. Accuracy of home blood pressure readings: monitors and operators.

    Science.gov (United States)

    Stryker, Trina; Wilson, Merne; Wilson, Thomas W

    2004-06-01

    To evaluate the accuracy of automated digital blood pressure monitoring devices and operators in the community. Also, we tested the effects of a simple education program, and looked for arm-arm differences. Subjects who had bought their own automated digital blood pressure monitor were recruited via an advertisement in the local newspaper. On arrival, they were asked to record their blood pressure exactly as they would at home. The investigator noted any technique deficiencies then corrected them. Blood pressures were then recorded by the investigator and the subject, on opposite arms, simultaneously, and repeated with the arms switched. Finally, subjects recorded their blood pressure again. The subjects' readings were compared to the average of monitor and mercury readings using Bland-Altman methods. A total of 80 subjects were tested. Before educating, subjects' systolic blood pressure (SBP) readings were +5.8+/-6.4 (standard deviation) mmHg greater than the mean of all readings, and diastolic blood pressure (DBP) were +1.3+/-4.0 mmHg; after educating they were +1.3+/-4.0 and -1.3+/-2.7 respectively. The monitors, as a group, were accurate, and met British Hypertension Society and AAMI highest standards. We found no differences among monitors that had been validated (n=26) and those that had not. There were differences between the arms: 5.3+/-5.2 mmHg for SBP and 3.4+/-3.3 mmHg for DBP. Most patients had never been informed by anyone of proper blood pressure measuring techniques. We conclude that home blood pressure measurement, as practiced in our community, is prone to error, mostly due to mistakes by the operator. These can easily be corrected, so that readings become more accurate. Attention should be paid to arm-arm differences.

  6. Proportion of root-derived acid phosphomonoesterase in total soil acid phosphomonoesterase in different forests

    Directory of Open Access Journals (Sweden)

    Ladislav Holík

    2011-01-01

    Full Text Available Enzyme acid phosphomonoesterase (APM plays an important role in phosphorus mineralization in different type of terrestrial ecosystems. This enzyme is of great agronomic significance because it hydrolyses organic phosphorus to different forms of inorganic phosphorus which are assimilable by plants. APM may also indicate changes in the quantity and quality of phosphorylated substrates in soil and is a good indicator of its biological state as well as presence of pollutants. APM may be produced by plant roots and soil microorganisms and both of these sources may play different role in phosphorus mineralization in different ecosystems. The aim of this work was determine acid phosphomonoesterase (APM activity location in soil of different forest ecosystems. The APM activity location determination was performed on the basis of root-derived and soil-derived APM and expression of proportion of those root-derived in total soil APM up to 13 cm depth. The results of this preliminary study showed that root-derived APM formed 21–34 % of total soil APM in pine and oak forest.

  7. Genetic admixture, social-behavioural factors and body composition are associated with blood pressure differently by racial-ethnic group among children.

    Science.gov (United States)

    Klimentidis, Y C; Dulin-Keita, A; Casazza, K; Willig, A L; Allison, D B; Fernandez, J R

    2012-02-01

    Cardiovascular disease has a progressively earlier age of onset, and disproportionately affects African Americans (AAs) in the United States. It has been difficult to establish the extent to which group differences are due to physiological, genetic, social or behavioural factors. In this study, we examined the association between blood pressure and these factors among a sample of 294 children, identified as AA, European American or Hispanic American. We use body composition, behavioural (diet and physical activity) and survey-based measures (socio-economic status and perceived racial discrimination), as well as genetic admixture based on 142 ancestry informative markers (AIMs) to examine associations with systolic and diastolic blood pressure. We find that associations differ by ethnic/racial group. Notably, among AAs, physical activity and perceived racial discrimination, but not African genetic admixture, are associated with blood pressure, while the association between blood pressure and body fat is nearly absent. We find an association between blood pressure and an AIM near a marker identified by a recent genome-wide association study. Our findings shed light on the differences in risk factors for elevated blood pressure among ethnic/racial groups, and the importance of including social and behavioural measures to grasp the full genetic/environmental aetiology of disparities in blood pressure.

  8. Thermal hydraulic analysis of aggressive secondary cooldown in a small break loss of coolant accident with a total loss of high pressure safety injection

    International Nuclear Information System (INIS)

    Han, Seok Jung; Lim, Ho Gon; Yang, Joon Eon

    2003-01-01

    To support the development of a Probabilistic Safety Assessment (PSA) model usable in Riskinformed Applications (RIA) for Korea Standard Nuclear power Plants (KSNP), we have performed a thermal hydraulic analysis of Aggressive Secondary Cooldown (ASC) in a 2-inch Small Break Loss Of Coolant Accident (SBLOCA) with a total loss of High Pressure Safety Injection (HPSI). The present study focuses on the estimation of the success criteria of ASC, and the enhanced understanding of the detailed thermal hydraulic behavior and phenomena. The results have shown that the Reactor Coolant System (RCS) pressure can be reduced to the Low Pressure Safety Injection (LPSI) operation conditions without core damage. It was also shown that more relaxed success criteria compared to those in the previous PSA models of KSNP could be used in the new PSA model. However, it was found that the results could be affected by various parameters related with ASC operation, i.e., reference temperature for the calculation of the cooldown rate and its control method

  9. The application of air pressure difference in reducing indoor radon concentration

    International Nuclear Information System (INIS)

    Leung, J.K.C.; Tso, M.Y.W.

    2000-01-01

    In densely populated tropical cities like Hong Kong, people usually live and work inside high-rise buildings. And because of the hot and humid climate, air conditioning systems are used throughout the year, particularly in commercial buildings. Previous territory-wide surveys have shown that over 10% of commercial buildings in Hong Kong have indoor radon concentrations above 200 Bq m -3 . Since the major source of indoor radon in high-rise buildings is the building materials, increasing ventilation and applying radon barriers on wall surfaces seem to be the only ways to reduce the indoor radon concentration. But it was noted that the ventilation rate the many commercial buildings are not efficient enough to remove the radon because of various reasons such as energy saving, lack of maintenance, etc. In this study, radon mitigation was achieved by reducing the rate of radon exhaled from the building materials. A special laboratory, which has the capability of simulating any meteorological conditions that could be faced by high-rise buildings in Hong Kong, was built. The reduction of radon exhalation rate by applying pressure difference and temperature difference across walls was studied in the laboratory. This paper summarizes the results and tactics for applying pressure difference in existing commercial buildings. A new technique of reducing radon exhalation rate in new buildings by depressurizing the interior of walls was also developed. Tunnels can be embedded in the concrete walls of new buildings during construction. By using simple vacuum pumps, radon exhalation rate from the walls can be reduced significantly by depressurizing the tunnels. The feasibility and applicability of the technique is presented in this paper. (author)

  10. Targeting for energy efficiency and improved energy collaboration between different companies using total site analysis (TSA)

    International Nuclear Information System (INIS)

    Hackl, Roman; Andersson, Eva; Harvey, Simon

    2011-01-01

    Rising fuel prices, increasing costs associated with emissions of green house gases and the threat of global warming make efficient use of energy more and more important. Industrial clusters have the potential to significantly increase energy efficiency by energy collaboration. In this paper Sweden's largest chemical cluster is analysed using the total site analysis (TSA) method. TSA delivers targets for the amount of utility consumed and generated through excess energy recovery by the different processes. The method enables investigation of opportunities to deliver waste heat from one process to another using a common utility system. The cluster consists of 5 chemical companies producing a variety of products, including polyethylene (PE), polyvinyl chloride (PVC), amines, ethylene, oxygen/nitrogen and plasticisers. The companies already work together by exchanging material streams. In this study the potential for energy collaboration is analysed in order to reach an industrial symbiosis. The overall heating and cooling demands of the site are around 442 MW and 953 MW, respectively. 122 MW of heat is produced in boilers and delivered to the processes. TSA is used to stepwise design a site-wide utility system which improves energy efficiency. It is shown that heat recovery in the cluster can be increased by 129 MW, i.e. the current utility demand could be completely eliminated and further 7 MW excess steam can be made available. The proposed retrofitted utility system involves the introduction of a site-wide hot water circuit, increased recovery of low pressure steam and shifting of heating steam pressure to lower levels in a number heat exchangers when possible. Qualitative evaluation of the suggested measures shows that 60 MW of the savings potential could to be achieved with moderate changes to the process utility system corresponding to 50% of the heat produced from purchased fuel in the boilers of the cluster. Further analysis showed that after implementation

  11. Drilling Performance of Rock Drill by High-Pressure Water Jet under Different Configuration Modes

    Directory of Open Access Journals (Sweden)

    Songyong Liu

    2017-01-01

    Full Text Available In the rock drilling progress, the resistant force results in tools failure and the low drilling efficiency; thus, it is necessary to reduce the tools failure and enhance the drilling efficiency. In this paper, different configuration modes of drilling performance assisted with water jet are explored based on the mechanism and experiment analysis of rock drilling assisted with water jet. Moreover, the rotary sealing device with high pressure is designed to achieve the axial and rotation movement simultaneously as well as good sealing effect under high-pressure water jet. The results indicate that the NDB and NFB have better effects on drilling performance compared with that of NSB. Moreover, the high-pressure water jet is helpful not only to reduce the drill rod deflection, but also to reduce the probability of drill rod bending and improve the drill rod service life.

  12. Dynamic mechanical properties and anisotropy of synthetic shales with different clay minerals under confining pressure

    Science.gov (United States)

    Gong, Fei; Di, Bangrang; Wei, Jianxin; Ding, Pinbo; Shuai, Da

    2018-03-01

    The presence of clay minerals can alter the elastic behaviour of reservoir rocks significantly as the type of clay minerals, their volume and distribution, and their orientation control the shale's intrinsic anisotropic behaviours. Clay minerals are the most abundant materials in shale, and it has been proven extremely difficult to measure the elastic properties of natural shale by means of a single variable (in this case, the type of clay minerals), due to the influences of multiple factors, including water, TOC content and complex mineral compositions. We used quartz, clay (kaolinite, illite and smectite), carbonate and kerogen extract as the primary materials to construct synthetic shale with different clay minerals. Ultrasonic experiments were conducted to investigate the anisotropy of velocity and mechanical properties in dry synthetic and natural shale as a function of confining pressure. Velocities in synthetic shale are sensitive to the type of clay minerals, possibly due to the different structures of the clay minerals. The velocities increase with confining pressure and show higher rate of velocity increase at low pressures, and P-wave velocity is usually more sensitive than S-wave velocity to confining pressure according to our results. Similarly, the dynamic Young's modulus and Poisson's ratio increase with applied pressure, and the results also reveal that E11 is always larger than E33 and ν31 is smaller than ν12. Velocity and mechanical anisotropy decrease with increasing stress, and are sensitive to stress and the type of clay minerals. However, the changes of mechanical anisotropy with applied stress are larger compared with the velocity anisotropy, indicating that mechanical properties are more sensitive to the change of rock properties.

  13. COMMUNITY SCALE STREAM TAXA SENSITIVITIES TO DIFFERENT COMPOSITIONS OF EXCESS TOTAL DISSOLVED SOLIDS

    Science.gov (United States)

    Model stream chronic dosing studies (42 d) were conducted with three total dissolved solids (TDS) recipes. The recipes differed in composition of major ions. Community scale emergence was compared with single-species responses conducted simultaneously using the whole effluent tox...

  14. The variability of ankle-arm blood pressure difference and ankle-brachial index in treated hypertensive patients.

    Science.gov (United States)

    Cao, Kaiwu; Xu, Jinsong; Sun, Hanjun; Li, Ping; Li, Juxiang; Cheng, Xiaoshu; Su, Hai

    2014-10-01

    The purpose of this study was to investigate whether ankle-arm blood pressure (BP) difference (An-a) and ankle-brachial index (ABI) are consistent in treated hypertensive patients with obvious BP variation. This study enrolled 414 hypertensive patients (200 males; mean age, 61.3 ± 13.3 years) admitted to our hospital. BP of four limbs was simultaneously measured using four automatic BP measurement devices on the day of admission, and three and six day after admission. The An-a differences on systolic BP (SBP), diastolic BP (DBP), mean artery pressure (MAP), and pulse pressure (PP) in both sides were calculated, respectively. The relative decrease amplitude (RDA) of BP was calculated using the formula: RDA = (BP1 - BPn)/BP1. The ABI of the right side was calculated. From the first to the third measurement, arm SBP and DBP levels of both arms significantly decreased (right arm: SBP: 163.7 ± 18.4, 147.7 ± 15.3 vs. 135.4 ± 11.7 mm Hg; P differences on SBP, DBP, PP, and MAP are generally consistent, but sABI is associated with underlying SBP levels.

  15. Real-world effectiveness of valsartan on hypertension and total cardiovascular risk: review and implications of a translational research program

    Science.gov (United States)

    Abraham, Ivo; MacDonald, Karen; Hermans, Christine; Aerts, Ann; Lee, Christopher; Brié, Heidi; Vancayzeele, Stefaan

    2011-01-01

    , including the proportion of variance attributable to a physician class effect before patients enter the equation. In its different formulations, valsartan has major real-world benefits in lowering blood pressure and total cardiovascular risk within a 90-day period. It is essential to understand the physician- and patient-related determinants of blood pressure and total cardiovascular risk outcomes associated with valsartan treatment. Antihypertensive research should expand its historical focus on lowering blood pressure with an emphasis on lowering total cardiovascular research. PMID:21490947

  16. Gender differences in walking (for leisure, transport and in total) across adult life: a systematic review.

    Science.gov (United States)

    Pollard, Tessa M; Wagnild, Janelle M

    2017-04-20

    The aim of this systematic review was to examine gender differences in walking for leisure, transport and in total in adults living in high-income countries, and to assess whether gender differences in walking practices change across the life-course. A systematic literature search was conducted of publications dated 1995 to 2015. Papers providing quantitative data on participation in walking of both men and women aged at least 18 years in a high-income country were screened for the quality of the data on gender differences in walking. Data were extracted and results were synthesised using forest plots and narrative summary. Thirty-six studies were included in the review: 18 reported on walking for leisure, 16 on walking for transport (in total, or for particular purposes), and 14 on total walking. Most (33) studies provided data comparing the proportion of men and women who walked (at all or for a minimum duration) over a defined period, usually one week. There was consistent evidence that more women than men walk for leisure, although effect sizes were small. However, this effect varies by age: more younger women than younger men walk for leisure, but the gender difference diminishes with age and appears to reverse in the oldest age groups. Taking all ages together, there was no consistent gender difference in walking for transport or in total walking, although the small number of studies reporting on walking to undertake errands suggested that more women than men walk for this purpose. While there is little evidence that levels of total walking consistently vary by gender, our findings suggest that there are consistent gender differences in participation in walking for some purposes, including for leisure, and that there are gender differences in the impact of age on walking. We conclude that more research is needed to improve our understanding of how walking fits into the lives of women and men across the life-course, especially in relation to gender

  17. Simulation of a scenario of total loss of external and internal power (Sbo) for different vent pressures of the containment of a BWR-5; Simulacion de un escenario de perdida total de potencia externa e interna (SBO) para distintas presiones de venteo de la contencion de un reactor BWR-5

    Energy Technology Data Exchange (ETDEWEB)

    Cardenas V, J.; Mugica R, C. A.; Godinez S, V., E-mail: Jaime.cardenas@cnsns.gob.mx [Comision Nacional de Seguridad Nuclear y Salvaguardias, Dr. Barragan No. 779, Col. Narvarte, 03020 Mexico D. F. (Mexico)

    2014-10-15

    The simulation of a Station Black Out (Sbo) was realized with intervention of the vent containment by means of a rigid vent coming from the dry-well and that discharges directly to the atmosphere, with the MELCOR code version 2.1. This scenario was carried out for a BWR-5 and containment type Mark II, with a thermal power of 2317 MWt similar to the reactor of nuclear power plant of Laguna Verde. For this scenario was considered as only available system for coolant injection to the reactor to the Reactor Core Isolation Cooling (Rcic), which remained operating 4 hours with batteries bank. The Security and Relief Valves (SR V) were considered functional (by simplicity) and that they mechanically do not exceed their capacity to liberate pressure due to the performances in their safety way. The operator maneuver to perform the SR V and to de pressurize the vessel until the pressure (13 kg/cm{sup 2}) to operate the low pressure systems was modeled. The results cover approximately 48 hours (172000 seconds), time in which was observed the behavior of the level and pressure in the vessel. Also the scenario evolution was analyzed to different vent pressures of the primary containment (2.0, 3.0, 4.5, 6.0, and 10.0 kg/cm{sup 2}), the temperature profiles of the dry-well, the hydrogen accumulation in the containment, the radio-nuclides liberation through rigid vent to the atmosphere and the inventory of these. In this work an analysis of the pressure behavior in the primary containment is presented, with the purpose of minimizing liberated fission products to the environment. (Author)

  18. Evidence for skill level differences in the thought processes of golfers during high and low pressure situations.

    Directory of Open Access Journals (Sweden)

    Amy Elizabeth Whitehead

    2016-01-01

    Full Text Available Two studies examined differences in the cognition of golfers with differing levels of expertise in high and low pressure situations. In study 1, six high skill and six low skill golfers performed six holes of golf, while verbalizing their thoughts using Think Aloud (TA protocol. Higher skilled golfers’ cognitive processes centered more on planning in comparison to lower skilled golfers. Study 2 investigated whether thought processes of golfers changed in response to competitive pressure. Eight high skill and eight moderate skilled golfers, completed a practice round and a competition round whilst verbalizing thoughts using TA. To create pressure in the competition condition, participants were instructed that monetary prizes would be awarded to the top three performers and scores of all golfers would be published in a league table in the club house. When performing under competitive pressure, it was found that higher skilled golfers were more likely to verbalize technical rules compared to practice conditions, especially during putting performance. This shift in cognition toward more technical aspects of motor performance was strongly related to scores on the Decision Specific Reinvestment Scale, suggesting individuals with a higher propensity for reinvestment show the largest changes in cognition under pressure. From a practical perspective, TA can aid a player, coach or sport psychologist by allowing thought processes to be identified and investigate a performer’s thoughts when faced with the pressure of a competition.

  19. Sex differences in step count-blood pressure association: a preliminary study in type 2 diabetes.

    Directory of Open Access Journals (Sweden)

    Priya Manjoo

    Full Text Available BACKGROUND: Walking and cardiovascular mortality are inversely associated in type 2 diabetes, but few studies have objectively measured associations of walking with individual cardiovascular risk factors. Such information would be useful for "dosing" daily steps in clinical practice. This study aimed to quantify decrements in blood pressure and glycated hemoglobin (A1C per 1,000 daily step increments. METHODOLOGY/PRINCIPAL FINDINGS: Two hundred and one subjects with type 2 diabetes underwent assessments of step counts (pedometer-measured, blood pressure, A1C and anthropometric parameters. Due to missing data, the final analysis was conducted on 83 women and 102 men, with a mean age of 60 years. Associations of daily steps with blood pressure and A1C were evaluated using sex-specific multivariate linear regression models (adjusted for age, ethnicity, and BMI. Potential sex differences were confirmed in a combined model (women and men with interaction terms. Mean values for daily steps, blood pressure, A1C and BMI were 5,357 steps/day; 137/80 mm Hg; 7.7% and 30.4 kg/m(2 respectively. A 1,000 daily step increment among women was associated with a -2.6 (95% CI: -4.1 to -1.1 mm Hg change in systolic and a -1.4 (95% CI: -2.2 to -0.6 mm Hg change in diastolic blood pressure. Among men, corresponding changes were -0.7 (95% CI: -2.1 to 0.7 and -0.6 (95% CI: -1.4 to 0.3 mm Hg, respectively. Sex differences were confirmed in combined models. Step counts and A1C did not demonstrate clinically important associations. CONCLUSIONS/SIGNIFICANCE: A 1,000 steps/day increment is associated with important blood pressure decrements among women with type 2 diabetes but the data were inconclusive among men. Targeted "dose increments" of 1,000 steps/day in women may lead to measurable blood pressure reductions. This information may be of potential use in the titration or "dosing" of daily steps. No associations were found between step count increments and A1C.

  20. Optimizing the physical ergonomics indices for the use of partial pressure suits.

    Science.gov (United States)

    Ding, Li; Li, Xianxue; Hedge, Alan; Hu, Huimin; Feathers, David; Qin, Zhifeng; Xiao, Huajun; Xue, Lihao; Zhou, Qianxiang

    2015-03-01

    This study developed an ergonomic evaluation system for the design of high-altitude partial pressure suits (PPSs). A total of twenty-one Chinese males participated in the experiment which tested three types of ergonomics indices (manipulative mission, operational reach and operational strength) were studied using a three-dimensional video-based motion capture system, a target-pointing board, a hand dynamometer, and a step-tread apparatus. In total, 36 ergonomics indices were evaluated and optimized using regression and fitting analysis. Some indices that were found to be linearly related and redundant were removed from the study. An optimal ergonomics index system was established that can be used to conveniently and quickly evaluate the performance of different pressurized/non-pressurized suit designs. The resulting ergonomics index system will provide a theoretical basis and practical guidance for mission planners, suit designers and engineers to design equipment for human use, and to aid in assessing partial pressure suits. Copyright © 2014 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  1. Skin perfusion pressure measured by isotope washout in legs with arterial occlusive disease. Evaluation of different tracers, comparison to segmental systolic pressure, angiography and transcutaneous oxygen tension and variations during changes in systemic blood pressure

    DEFF Research Database (Denmark)

    Holstein, P; Trap-Jensen, J; Bagger, H

    1983-01-01

    Hg (range 18-98) (P less than 0.02). The average washout constant for the three different tracers were approximately equal and correlated statistically significant with the SPP; (2) In 59 legs with AOD, segmental SPP was compared to segmental systolic blood pressures on the thigh, calf, ankle and first...... digit (strain gauge technique). The two different methods correlated statistically significant at all four levels, but the systolic blood pressures were higher than the SPP in particular in diabetic legs; (3) Angiograms in 35 legs with AOD showed that the SPP on the ankle was only consistently decreased...

  2. The effects of different lying positions on interface pressure, skin temperature, and tissue blood flow in nursing home residents.

    Science.gov (United States)

    Källman, Ulrika; Engström, Maria; Bergstrand, Sara; Ek, Anna-Christina; Fredrikson, Mats; Lindberg, Lars-Göran; Lindgren, Margareta

    2015-03-01

    Although repositioning is considered an important intervention to prevent pressure ulcers, tissue response during loading in different lying positions has not been adequately explored. To compare the effects of different lying positions on interface pressure, skin temperature, and tissue blood flow in nursing home residents. From May 2011 to August 2012, interface pressure, skin temperature, and blood flow at three tissue depths were measured for 1 hr over the sacrum in 30° supine tilt and 0° supine positions and over the trochanter major in 30° lateral and 90° lateral positions in 25 residents aged 65 years or older. Measurement of interface pressure was accomplished using a pneumatic pressure transmitter connected to a digital manometer, skin temperature using a temperature sensor, and blood flow using photoplethysmography and laser Doppler flowmetry. Interface pressure was significantly higher in the 0° supine and 90° lateral positions than in 30° supine tilt and 30° lateral positions. The mean skin temperature increased from baseline in all positions. Blood flow was significantly higher in the 30° supine tilt position compared to the other positions. A hyperemic response in the post pressure period was seen at almost all tissue depths and positions. The 30° supine tilt position generated less interface pressure and allowed greater tissue perfusion, suggesting that this position is the most beneficial. © The Author(s) 2014.

  3. Inter-arm Differences in Simultaneous Blood Pressure Measurements in Ambulatory Patients without Cardiovascular Diseases.

    Science.gov (United States)

    Kim, Kyoung Bog; Oh, Mi Kyeong; Kim, Haa Gyoung; Ki, Ji Hoon; Lee, Soo Hee; Kim, Su Min

    2013-03-01

    It has traditionally been known that there is normally a difference in blood pressure (BP) between the two arms; there is at least 20 mm Hg difference in the systolic blood pressure (SBP) and 10 mm Hg difference in the diastolic blood pressure (DBP). However, recent epidemiologic studies have shown that there are between-arm differences of arm differences in simultaneous BP measurements obtained from ambulatory patients without cardiovascular diseases and to identify the factors associated these differences. We examined 464 patients who visited the outpatient clinic of Gangneung Asan Hospital clinical department. For the current analysis, we excluded patients with ischemic heart disease, stroke, arrhythmia, congestive heart failure, or hyperthyroidism. Simultaneous BP measurements were obtained using the Omron MX3 BP monitor in both arms. The inter-arm difference (IAD) in BP was expressed as the relative difference (right-arm BP [R] minus left-arm BP [L]: R - L) and the absolute difference (|R - L|). The mean absolute IAD in SBP and DBP were 3.19 ± 2.38 and 2.41 ± 1.59 mm Hg, respectively, in men and 2.61 ± 2.18 and 2.25 ± 2.01 mm Hg, respectively, in women. In men, there were 83.8% of patients with the IAD in SBP of ≤ 6 mm Hg, 98.1% with the IAD in SBP of ≤ 10 mm Hg, 96.5% with the IAD in DBP of ≤ 6 mm Hg and 0% with the IAD in DBP of > 10 mm Hg. In women, 89.6% of patients had IAD in SBP of ≤ 6 mm Hg, 92.1% with IAD in DBP of ≤ 6 mm Hg, and 0% with IAD in SBP of > 10 mm Hg or IAD in DBP of > 10 mm Hg. Gangneung Asan Hospital clinical series of patients showed that the absolute IAD in SBP had a significant correlation with cardiovascular risk factors such as the 10-year Framingham cardiac risk scores and higher BP in men and higher BP in women. However, the absolute IAD in SBP and DBP had no significant correlation with the age, obesity, smoking, drinking, hyperlipidemia, diabetes, metabolic syndrome, and renal function. Our results showed that there

  4. Membrane distillation against a pressure difference

    OpenAIRE

    Keulen, L.; van der Ham, L.V.; Kuipers, N.J.M.; Hanemaaijer, J.H.; Vlugt, T.J.H.; Kjelstrup, S.

    2017-01-01

    Membrane distillation is an attractive technology for production of fresh water from seawater. The MemPower®MemPower® concept, studied in this work, uses available heat (86 °C) to produce pressurized water (2.2 bar and 46 °C) by membrane distillation, which again can be used to power a turbine for co-production of electricity. We develop a non-equilibrium thermodynamic model to accurately describe the transfer at the liquid-membrane interfaces, as well as through the hydrophobic membrane. The...

  5. A randomised, controlled clinical study on total hip arthroplasty using 4 different bearings

    DEFF Research Database (Denmark)

    Borgwardt, Arne; Zerahn, Bo; Fabricius, Sandra D

    2017-01-01

    PURPOSE: To compare 4 different bearings in total hip arthroplasty (THA) in a randomised controlled clinical study on clinical performance. METHODS: 393 patients with osteoarthritis of the hip or avascular necrosis were included and allocated to 1 of the head-and-cup couples zirconia...

  6. Effects of different computer typing speeds on acceleration and peak contact pressure of the fingertips during computer typing.

    Science.gov (United States)

    Yoo, Won-Gyu

    2015-01-01

    [Purpose] This study showed the effects of different computer typing speeds on acceleration and peak contact pressure of the fingertips during computer typing. [Subjects] Twenty-one male computer workers voluntarily consented to participate in this study. They consisted of 7 workers who could type 200-300 characteristics/minute, 7 workers who could type 300-400 characteristics/minute, and 7 workers who could type 400-500 chracteristics/minute. [Methods] This study was used to measure the acceleration and peak contact pressure of the fingertips for different typing speed groups using an accelerometer and CONFORMat system. [Results] The fingertip contact pressure was increased in the high typing speed group compared with the low and medium typing speed groups. The fingertip acceleration was increased in the high typing speed group compared with the low and medium typing speed groups. [Conclusion] The results of the present study indicate that a fast typing speed cause continuous pressure stress to be applied to the fingers, thereby creating pain in the fingers.

  7. High voltage tests of an electrostatic accelerator for different mixtures of gases at various pressures

    International Nuclear Information System (INIS)

    Hellborg, R.

    1996-01-01

    An account is given of high voltage tests of an electrostatic accelerator. High voltage conditioning is measured and is reported for the same accelerator tube after different periods of usage. Tests of different mixtures of sulphur hexafluoride and nitrogen have been performed. A considerable amount of data was obtained for various parameters connected with the high voltage system for different proportions of nitrogen in sulphur hexafluoride at various gas pressures. (orig.)

  8. The influence of NDT-Bobath and PNF methods on the field support and total path length measure foot pressure (COP) in patients after stroke.

    Science.gov (United States)

    Krukowska, Jolanta; Bugajski, Marcin; Sienkiewicz, Monika; Czernicki, Jan

    In stroke patients, the NDT - (Bobath - Neurodevelopmental Treatment) and PNF (Proprioceptive Neuromuscular Facilitation) methods are used to achieve the main objective of rehabilitation, which aims at the restoration of maximum patient independence in the shortest possible period of time (especially the balance of the body). The aim of the study is to evaluate the effect of the NDT-Bobath and PNF methods on the field support and total path length measure foot pressure (COP) in patients after stroke. The study included 72 patients aged from 20 to 69 years after ischemic stroke with Hemiparesis. The patients were divided into 4 groups by a simple randomization. The criteria for this division were: the body side (right or left) affected by paresis and the applied rehabilitation methods. All the patients were applied the recommended kinesitherapeutic method (randomized), 35 therapy sessions, every day for a period of six weeks. Before initiation of therapy and after 6 weeks was measured the total area of the support and path length (COP (Center Of Pressure) measure foot pressure) using stabilometer platform - alpha. The results were statistically analyzed. After treatment studied traits decreased in all groups. The greatest improvement was obtained in groups with NDT-Bobath therapy. NDT-Bobath method for improving the balance of the body is a more effective method of treatment in comparison with of the PNF method. In stroke patients, the effectiveness of NDT-Bobath method does not depend on hand paresis. Copyright © 2016 Polish Neurological Society. Published by Elsevier Urban & Partner Sp. z o.o. All rights reserved.

  9. Pressure changes in the plasma sheet during substorm injections

    International Nuclear Information System (INIS)

    Kistler, L.M.; Moebuis, E.; Baumjohann, W.; Paschmann, G.; Hamilton, D.C.

    1992-01-01

    The authors have determined the particle pressure and total pressure as a function of radial distance in the plasma sheet for periods before and after the onset of substorm-associated ion enhancements over the radial range 7-19 R E . They have chosen events occurring during times of increasing magnetospheric activity, as determined by an increasing AE index, in which a sudden increase, or injection, of energetic particle flux is observed. During these events the particle energy of maximum contribution to the pressure increases from about 12 to about 27 keV. In addition, the particle pressure increases, and the magnetic pressure decreases, with the total pressure only changing slightly. For radial distances of less than 10 R E the total pressure tends to increase with the injection, while outside 10 R E it tends to decrease or remain the same. Because the fraction of the pressure due to particles has increased and higher energies are contributing to the pressure, a radial gradient is evident in the postinjection, but not preinjection, flux measurements. These observations show that the simulations appearance of energetic particles and changes in the magnetic field results naturally from pressure balance and does not necessarily indicate that the local changing field is accelerating the particles. The changes in the total pressure outside 10 R E are consistent with previous measurements of pressure changes at substorm onset and can be understood in terms of the unloading of energy in the magnetotail and the resulting change in the magnetic field configuration

  10. Solvation pressure as real pressure: I. Ethanol and starch under negative pressure

    CERN Document Server

    Uden, N W A V; Faux, D A; Tanczos, A C; Howlin, B; Dunstan, D J

    2003-01-01

    The reality of the solvation pressure generated by the cohesive energy density of liquids is demonstrated by three methods. Firstly, the Raman spectrum of ethanol as a function of cohesive energy density (solvation pressure) in ethanol-water and ethanol-chloroform mixtures is compared with the Raman spectrum of pure ethanol under external hydrostatic pressure and the solvation pressure and hydrostatic pressure are found to be equivalent for some transitions. Secondly, the bond lengths of ethanol are calculated by molecular dynamics modelling for liquid ethanol under pressure and for ethanol vapour. The difference in bond lengths between vapour and liquid are found to be equivalent to the solvation pressure for the C-H sub 3 , C-H sub 2 and O-H bond lengths, with discrepancies for the C-C and C-O bond lengths. Thirdly, the pressure-induced gelation of potato starch is measured in pure water and in mixtures of water and ethanol. The phase transition pressure varies in accordance with the change in solvation pre...

  11. Determination of total triterpenoid acids in different part and extract of Ganoderma lucidum

    Directory of Open Access Journals (Sweden)

    FENG Huiqin

    2013-04-01

    Full Text Available Aim To develop a method for determination of total triterpenoid acids in different part and extracts of Ganoderma lucidum. Method The samples of Ganoderma lucidum were extracted with ethanol and successively extracted with CHCl3 and 5% NaHCO3,the NaHCO3 layer was acidified to pH 3 with 2 mol/L HCl,the resulting precipitates were dissolved in CHCl3 and evaporated in vacuo then weighed. The total triterpenoid acids were obtained. Result The total triterpenoid acids of Ganoderma lucidum fruitbody,spore and mycelium were (8.58±0.25 mg/g,(3.48±0.03 mg/g and (1.75 ±0.09 mg/g respectively. The total triterpenoid acids of pileus and stipe were (12.62±0.22 mg/g and (7.66±0.08 mg/g. The range of total triterpenoid acid content among 10 batches of Ganoderma lucidum fruitbody purchased from the market was between 4.34 to 16.39 mg/g. The highest content fro/8/8/88/ m Ganoderma lucidum fruiting body with alcohol - water extracting was (208.70±5.54 mg/g and the lowest content with alkaline solution extracting was (123.07±4.99 mg/g. The composition of total triterpenoid acid from fruitbody,spores and extract of fruitbody analyzed by HPLC were almost the same. This method is reliable for determination of total triterpenoid acid in the fruiting body and its extracts,spore and mycelium from Ganoderma lucidum,which provides an indicator for the quality of Ganoderma lucidum product.

  12. CANFLEX fuel bundle junction pressure drop

    International Nuclear Information System (INIS)

    Chung, H. J.; Chung, C. H.; Jun, J. S.; Hong, S. D.; Chang, S. K.; Kim, B. D.

    1996-11-01

    This report describes the junction pressure drop test results which are to used to determine the alignment angle between bundles to achieve the most probable fuel string pressure drop for randomly aligned bundles for use in the fuel string total pressure drop test. (author). 4 tabs., 17 figs

  13. CANFLEX fuel bundle junction pressure drop

    Energy Technology Data Exchange (ETDEWEB)

    Chung, H. J.; Chung, C. H.; Jun, J. S.; Hong, S. D.; Chang, S. K.; Kim, B. D.

    1996-11-01

    This report describes the junction pressure drop test results which are to used to determine the alignment angle between bundles to achieve the most probable fuel string pressure drop for randomly aligned bundles for use in the fuel string total pressure drop test. (author). 4 tabs., 17 figs.

  14. Differences in Activation Area Within Brodmann Area 2 Caused by Pressure Stimuli on Fingers and Joints: In Case of Male Subjects.

    Science.gov (United States)

    Choi, Mi-Hyun; Kim, Hyung-Sik; Baek, Ji-Hye; Lee, Jung-Chul; Park, Sung-Jun; Jeong, Ul-Ho; Gim, Seon-Young; Kim, Sung-Phil; Lim, Dae-Woon; Chung, Soon-Cheol

    2015-09-01

    In this study, a constant pressure stimulus was applied on the 3 joints (first [p1], second [p2], and third [p3] joints) of 4 fingers (index, middle, ring, and little fingers), and the activation areas within Brodmann area 2 (BA 2) were compared for these different fingers and joints by using functional magnetic resonance imaging. Eight healthy male college students (25.4 ± 1.32 years) participated in the study. Each session was composed of 3 blocks, and each block was composed of a Control phase (30 seconds) and a Pressure phase (30 seconds). No pressure stimulus was applied in the Control phase, during which the subjects would simply lay comfortably with their eyes closed. In the Pressure phase, a pressure stimulus was applied onto one of the joints of the selected finger. For each finger and joint, BA 2 areas activated by the pressure stimulus were extracted by the region of interest method. There was a significant difference in the activation areas for the different fingers (P = .042) as well as for the different joints (P = .050). The activation area decreased in the order of the little, index, and middle fingers, as well as in the order of p1, p3, and p2.

  15. Analytical calculations of the rotational transform angles in the torsatron systems with different plasma pressure profiles

    International Nuclear Information System (INIS)

    Kuznetsov, Yu.K.; Pinos, I.B.; Tyupa, V.I.

    1999-01-01

    With formulas for averaging over magnetic surfaces general analytical expressions are here deduced to determine the rotational transform angles in stellarator systems having different plasma pressure profiles

  16. Experimental and Computational Study of the Hydrodynamics of Trickle Bed Flow Reactor Operating Under Different Pressure Conditions

    Science.gov (United States)

    Rabbani, S.; Ben Salem, I.; Nadeem, H.; Kurnia, J. C.; Shamim, T.; Sassi, M.

    2014-12-01

    Pressure drop estimation and prediction of liquid holdup play a crucial role in design and operation of trickle bed reactors. Experiments are performed for Light Gas Oil (LGO)-nitrogen system in ambient temperature conditions in an industrial pilot plant with reactor height 0.79 m and diameter of 0.0183 m and pressure ranging from atmospheric to 10 bars. It was found that pressure drop increased with increase in system pressure, superficial gas velocity and superficial liquid velocity. It was demonstrated in the experiments that liquid holdup of the system increases with the increase in superficial liquid velocity and tends to decrease with increase in superficial gas velocity which is in good agreement with existing literature. Similar conditions were also simulated using CFD-software FLUENT. The Volume of Fluid (VoF) technique was employed in combination with "discrete particle approach" and results were compared with that of experiments. The overall pressure drop results were compared with the different available models and a new comprehensive model was proposed to predict the pressure drop in Trickle Bed Flow Reactor.

  17. Bridge to transplantation using paracorporeal biventricular assist devices or the syncardia temporary total artificial heart: is there a difference?

    Science.gov (United States)

    Nguyen, A; Pozzi, M; Mastroianni, C; Léger, P; Loisance, D; Pavie, A; Leprince, P; Kirsch, M

    2015-06-01

    Biventricular support can be achieved using paracorporeal ventricular assist devices (p-BiVAD) or the Syncardia temporary total artificial heart (t-TAH). The purpose of the present study was to compare survival and morbidity between these devices. Data from 2 French neighboring hospitals were reviewed. Between 1996 and 2009, 148 patients (67 p-BiVADs and 81 t-TAH) underwent primary, planned biventricular support. There were 128 (86%) males aged 44±13 years. Preoperatively, p-BiVAD recipients had significantly lower systolic and diastolic blood pressures, more severe hepatic cytolysis and higher white blood cell counts than t-TAH recipients. In contrast, t-TAH patients had significantly higher rates of pre-implant ECLS and hemofiltration. Mean support duration was 79±100 days for the p-BiVAD group and 71±92 for t-TAH group (P=0.6). Forty two (63%) p-BiVAD recipients were bridged to transplantation (39, 58%) or recovery (3, 5%), whereas 51 (63%) patients underwent transplantation in the t-TAH group. Death on support was similar between groups (p-BiVAD, 26 (39%); t-TAH, 30 (37%); P=0.87). Survival while on device was not significantly different between patient groups and multivariate analysis showed that only preimplant diastolic blood pressure and alanine amino-transferase levels were significant predictors of death. Post-transplant survival in the p-BiVAD group was 76±7%, 70±8%, and 58±9% at 1, 3, and 5 years after transplantation, respectively, and was similar to that of the t-TAH group (77±6%, 72±6%, and 70±7%, P=0.60). Survival while on support and up to 5 years after heart transplantation was not significantly different in patients supported by p-BiVADs or t-TAH. Multivariate analysis revealed that survival while on transplantation was not affected by the type of device implanted.

  18. Interarm Difference in Blood Pressure: Reproducibility and Association with Peripheral Vascular Disease

    OpenAIRE

    Mehlsen, Jesper; Wiinberg, Niels

    2014-01-01

    The present study aimed at examining the interarm difference in blood pressure and its use as an indicator of peripheral arterial disease (PAD). Data were included from consecutive patients referred from their general practitioner to our vascular laboratory for possible PAD aged 50 years or older without known cardiac disease, renal disease, or diabetes mellitus. 824 patients (453 women) with mean age of 72 years (range: 50–101) were included. 491 patients had a diagnosi...

  19. Work of breathing using different interfaces in spontaneous positive pressure ventilation: helmet, face-mask, and endotracheal tube.

    Science.gov (United States)

    Oda, Shinya; Otaki, Kei; Yashima, Nozomi; Kurota, Misato; Matsushita, Sachiko; Kumasaka, Airi; Kurihara, Hutaba; Kawamae, Kaneyuki

    2016-08-01

    Noninvasive positive pressure ventilation (NPPV) using a helmet is expected to cause inspiratory trigger delay due to the large collapsible and compliant chamber. We compared the work of breathing (WOB) of NPPV using a helmet or a full face-mask with that of invasive ventilation by tracheal intubation. We used a lung model capable of simulating spontaneous breathing (LUNGOO; Air Water Inc., Japan). LUNGOO was set at compliance (C) = 50 mL/cmH2O and resistance (R) = 5 cmH2O/L/s for normal lung simulation, C = 20 mL/cmH2O and R = 5 cmH2O/L/s for restrictive lung, and C = 50 mL/cmH2O and R = 20 cmH2O/L/s for obstructive lung. Muscle pressure was fixed at 25 cmH2O and respiratory rate at 20 bpm. Pressure support ventilation and continuous positive airway pressure were performed with each interface placed on a dummy head made of reinforced plastic that was connected to LUNGOO. We tested the inspiratory WOB difference between the interfaces with various combinations of ventilator settings (positive end-expiratory pressure 5 cmH2O; pressure support 0, 5, and 10 cmH2O). In the normal lung and restrictive lung models, WOB decreased more with the face-mask than the helmet, especially when accompanied by the level of pressure support. In the obstructive lung model, WOB with the helmet decreased compared with the other two interfaces. In the mixed lung model, there were no significant differences in WOB between the three interfaces. NPPV using a helmet is more effective than the other interfaces for WOB in obstructive lung disease.

  20. Dorsalis pedis arterial pressure is lower than noninvasive arm blood pressure in normotensive patients under sevoflurane anesthesia.

    Science.gov (United States)

    Chen, Yan; Wang, Enqin; Zhu, Yuan; Li, Yongshuai; Lu, Kaizhi

    2016-02-01

    It is widely known that blood pressure (BP) in the lower extremity is higher than in the upper extremity. However, whether this phenomenon remains the same during general anesthesia is still unclear. This study aims to investigate the difference between invasive dorsalis pedis artery (DPA) pressure and the most commonly used noninvasive arm pressure during sevoflurane anesthesia. A total of 50 normotensive Chinese patients were enrolled in this observational study. Invasive DPA pressure, noninvasive arm pressure, and systemic vascular resistance index were assessed simultaneously. BP data during the entire surgery were analyzed through a Bland-Altman plot for repeated measures. The concordance of BP variation in the DPA and the arm was analyzed using four-quadrant plots and linear regression. The time-dependent changes in BP and the systemic vascular resistance index were also evaluated. Data from 46 effective cases were analyzed. Bias (95% limits of agreement) was -7.40 mmHg (-20.36 to +5.57 mmHg) for mean blood pressure, +3.54 mmHg (-20.32 to +27.41 mmHg) for systolic blood pressure, and -10.20 mmHg (-23.66 to +3.26 mmHg) for diastolic blood pressure, respectively. The concordance of BP variation at the two measurement sites was clinically acceptable. DPA pressure and vascular resistance in the lower limb decreased gradually during surgery. DPA pressure tends to be lower than arm pressure under sevoflurane anesthesia, especially the mean blood pressure and the diastolic blood pressure. Hence, noninvasive arm BP monitoring is recommend to be retained when invasive BP is measured at the DPA, so as to allow clinicians to comprehensively evaluate the BP condition of the patients and make appropriate therapeutic decisions.

  1. Literature investigation of air/steam ingress through small cracks in concrete wall under pressure differences

    International Nuclear Information System (INIS)

    Jiang, J.T.

    2008-01-01

    Traditionally within CANDU safety analysis, a loss coefficient of ∼2.8 is used to characterize turbulent flow leakage through narrow, sharp-edged cracks into, and out of Steam Protected Rooms (SPRs). In the event of main steam line break (MSLB), the pressure differences observed between SPRs and the surrounding area of the powerhouse range from 0.01kPa to 0.1 kPa. The relatively low pressure differences, coupled with narrow crack sizes, for instance, below 1 mm, may result in laminar flow leakage pathways as opposed to the turbulent variety assumed in analysis. The main purpose of this paper is thus (a) to calculate the loss coefficient for laminar flow through small cracks; and (b) to assess the effect of steam ingress to SPRs when the flow through some or all of the room leakage area is assumed to be laminar. Based on the literature review, the loss coefficient for laminar flow, through 1 mm crack size at 0.1 kPa pressure difference, ranges from 10 to about 65. This value represents an increase in loss coefficient of 3 ∼ 22 times the loss coefficient used for SPR safety analysis. The actual volumetric leakage rate is therefore 3 ∼ 8 times smaller than the amount previously applied. This paper demonstrates how the traditional loss coefficient used in safety analysis is extremely conservative in the analysis of the SPRs steam ingress phenomenon. (author)

  2. Literature investigation of air/steam ingress through small cracks in concrete wall under pressure differences

    Energy Technology Data Exchange (ETDEWEB)

    Jiang, J.T. [McMaster Univ., Engineering Physics Dept., Hamilton, Ontario (Canada)], E-mail: jiangj3@mcmaster.ca

    2008-07-01

    Traditionally within CANDU safety analysis, a loss coefficient of {approx}2.8 is used to characterize turbulent flow leakage through narrow, sharp-edged cracks into, and out of Steam Protected Rooms (SPRs). In the event of main steam line break (MSLB), the pressure differences observed between SPRs and the surrounding area of the powerhouse range from 0.01kPa to 0.1 kPa. The relatively low pressure differences, coupled with narrow crack sizes, for instance, below 1 mm, may result in laminar flow leakage pathways as opposed to the turbulent variety assumed in analysis. The main purpose of this paper is thus (a) to calculate the loss coefficient for laminar flow through small cracks; and (b) to assess the effect of steam ingress to SPRs when the flow through some or all of the room leakage area is assumed to be laminar. Based on the literature review, the loss coefficient for laminar flow, through 1 mm crack size at 0.1 kPa pressure difference, ranges from 10 to about 65. This value represents an increase in loss coefficient of 3 {approx} 22 times the loss coefficient used for SPR safety analysis. The actual volumetric leakage rate is therefore 3 {approx} 8 times smaller than the amount previously applied. This paper demonstrates how the traditional loss coefficient used in safety analysis is extremely conservative in the analysis of the SPRs steam ingress phenomenon. (author)

  3. Ascorbic acid is the only bioactive that is better preserved by high hydrostatic pressure than by thermal treatment of a vegetable beverage.

    Science.gov (United States)

    Barba, Francisco J; Esteve, Maria J; Frigola, Ana

    2010-09-22

    Variations in levels of antioxidant compounds (ascorbic acid, total phenolics, and total carotenoids), total antioxidant capacity, and color changes in a vegetable (tomato, green pepper, green celery, onion, carrot, lemon, and olive oil) beverage treated by high hydrostatic pressure (HHP) were evaluated in this work. The effects of HHP treatment, four different pressures (100, 200, 300, and 400 MPa) and four treatment times for each pressure (from 120 to 540 s) were compared with those of thermal treatment (90-98 °C for 15 and 21 s). High pressure treatment retained significantly more ascorbic acid in the vegetable beverage than thermal treatment. However, no significant changes in total phenolics were observed between HHP treated and thermally processed vegetable beverage and unprocessed beverage. Color changes (a*, b*, L, chroma, h°, and ΔE) were less for pressurized beverage than thermally treated samples compared with unprocessed beverage.

  4. AUTOMATIC CONTROL SYSTEM OF THE DIFFERENCE BETWEEN DISCHARGE AND SUCTION PRESSURES OF THE HEAT PUMP STATION COMPRESSOR

    Directory of Open Access Journals (Sweden)

    Sit M.L.

    2009-04-01

    Full Text Available Possibility of realization is shown and the control system of a difference of pressure between an exit and an input of the compressor of the heat pump on carbon dioxide working at variable thermal load, and discharge and suction pressures by means of two control valves connected in series is developed. On an example a flow coefficient calculation procedure of control valves is shown.

  5. Low vs Standard Pressures in Gynecologic Laparoscopy: a Systematic Review.

    Science.gov (United States)

    Kyle, Esther B; Maheux-Lacroix, Sarah; Boutin, Amélie; Laberge, Philippe Y; Lemyre, Madeleine

    2016-01-01

    The optimal intraperitoneal pressure during laparoscopy is not known. Recent literature found benefits of using lower pressures, but the safety of doing abdominal surgery with low peritoneal pressures needs to be assessed. This systematic review compares low with standard pneumoperitoneum during gynecologic laparoscopy. We searched Medline, Embase, and the Cochrane Library for randomized controlled trials comparing intraperitoneal pressures during gynecologic laparoscopy. Two authors reviewed references and extracted data from included trials. Risk ratios, mean differences, and standard mean differences were calculated and pooled using RevMan5. Of 2251 studies identified, three were included in the systematic review, for a total of 238 patients. We found a statistically significant but modest diminution in postoperative pain of 0.38 standardized unit based on an original 10-point scale (95% confidence interval [CI], -0.67 to -0.08) during the immediate postoperative period when using low intraperitoneal pressure of 8 mm Hg compared with ≥ 12 mm Hg and of 0.50 (95% CI, -0.80 to -0.21) 24 hours after the surgery. Lower pressures were associated with worse visualization of the surgical field (risk ratio, 10.31; 95% CI, 1.29-82.38). We found no difference between groups over blood loss, duration of surgery, hospital length of stay, or the need for increased pressure. Low intraperitoneal pressures during gynecologic laparoscopy cannot be recommended on the behalf of this review because improvement in pain scores is minimal and visualization of the surgical field is affected. The safety of this intervention as well as cost-effectiveness considerations need to be further studied.

  6. Difference between right and left side in total knee and unicondylar knee replacement: An interesting observation

    Directory of Open Access Journals (Sweden)

    Vasudevan Thirumal Selvan

    2005-02-01

    Full Text Available We report an observation made about the differences between right and left side in case of total knee and unicondylar knee replacement. It was found that unicondylar knee replacement was performed more commonly on the left side (66%, as compared to only 34% on right side, where as total knee replacement was more common on the right side (64% as compared to 36% on left side. The exact clinical utility of this difference is yet to be known.

  7. Dosimetric evaluation of total marrow irradiation using 2 different planning systems

    International Nuclear Information System (INIS)

    Nalichowski, Adrian; Eagle, Don G.; Burmeister, Jay

    2016-01-01

    This study compared 2 different treatment planning systems (TPSs) for quality and efficiency of total marrow irradiation (TMI) plans. The TPSs used in this study were VOxel-Less Optimization (VoLO) (Accuray Inc, Sunnyvale, CA) using helical dose delivery on a Tomotherapy Hi-Art treatment unit and Eclipse (Varian Medical Systems Inc, Palo Alto, CA) using volumetric modulated arc therapy (VMAT) dose delivery on a Varian iX treatment unit. A total dose of 1200 cGy was prescribed to cover 95% of the planning target volume (PTV). The plans were optimized and calculated based on a single CT data and structure set using the Alderson Rando phantom (The Phantom Laboratory, Salem, NY) and physician contoured target and organ at risk (OAR) volumes. The OARs were lungs, heart, liver, kidneys, brain, and small bowel. The plans were evaluated based on plan quality, time to optimize the plan and calculate the dose, and beam on time. The resulting mean and maximum doses to the PTV were 1268 and 1465 cGy for VoLO and 1284 and 1541 cGy for Eclipse, respectively. For 5 of 6 OAR structures the VoLO system achieved lower mean and D10 doses ranging from 22% to 52% and 3% to 44%, respectively. Total computational time including only optimization and dose calculation were 0.9 hours for VoLO and 3.8 hours for Eclipse. These times do not include user-dependent target delineation and field setup. Both planning systems are capable of creating high-quality plans for total marrow irradiation. The VoLO planning system was able to achieve more uniform dose distribution throughout the target volume and steeper dose fall off, resulting in superior OAR sparing. VoLO's graphics processing unit (GPU)–based optimization and dose calculation algorithm also allowed much faster creation of TMI plans.

  8. Dosimetric evaluation of total marrow irradiation using 2 different planning systems

    Energy Technology Data Exchange (ETDEWEB)

    Nalichowski, Adrian, E-mail: nalichoa@karmanos.org [Karmanos Cancer Center, Detroit, MI (United States); Eagle, Don G. [Wayne State University School of Medicine, Detroit, MI (United States); Burmeister, Jay [Karmanos Cancer Center, Detroit, MI (United States); Wayne State University School of Medicine, Detroit, MI (United States)

    2016-10-01

    This study compared 2 different treatment planning systems (TPSs) for quality and efficiency of total marrow irradiation (TMI) plans. The TPSs used in this study were VOxel-Less Optimization (VoLO) (Accuray Inc, Sunnyvale, CA) using helical dose delivery on a Tomotherapy Hi-Art treatment unit and Eclipse (Varian Medical Systems Inc, Palo Alto, CA) using volumetric modulated arc therapy (VMAT) dose delivery on a Varian iX treatment unit. A total dose of 1200 cGy was prescribed to cover 95% of the planning target volume (PTV). The plans were optimized and calculated based on a single CT data and structure set using the Alderson Rando phantom (The Phantom Laboratory, Salem, NY) and physician contoured target and organ at risk (OAR) volumes. The OARs were lungs, heart, liver, kidneys, brain, and small bowel. The plans were evaluated based on plan quality, time to optimize the plan and calculate the dose, and beam on time. The resulting mean and maximum doses to the PTV were 1268 and 1465 cGy for VoLO and 1284 and 1541 cGy for Eclipse, respectively. For 5 of 6 OAR structures the VoLO system achieved lower mean and D10 doses ranging from 22% to 52% and 3% to 44%, respectively. Total computational time including only optimization and dose calculation were 0.9 hours for VoLO and 3.8 hours for Eclipse. These times do not include user-dependent target delineation and field setup. Both planning systems are capable of creating high-quality plans for total marrow irradiation. The VoLO planning system was able to achieve more uniform dose distribution throughout the target volume and steeper dose fall off, resulting in superior OAR sparing. VoLO's graphics processing unit (GPU)–based optimization and dose calculation algorithm also allowed much faster creation of TMI plans.

  9. Displacement of an electric arc by a stationary transverse magnetic field to different pressures of the ionized gas

    International Nuclear Information System (INIS)

    Ramos, J.

    1987-01-01

    The displacement of a wall-stabilized electric arc by a stationary transverse magnetic field is measured to different pressures of the ionized gas. The increase of the pressure makes the heat transfer function and the mass flow velocity in the arc column to raise, and it makes the arc displacement to decrease. (author)

  10. Impact of high pressure processing on color, bioactive compounds, polyphenol oxidase activity, and microbiological attributes of pumpkin purée.

    Science.gov (United States)

    González-Cebrino, Francisco; Durán, Rocío; Delgado-Adámez, Jonathan; Contador, Rebeca; Bernabé, Rosario Ramírez

    2016-04-01

    Physicochemical parameters, bioactive compounds' content (carotenoids and total phenols), total antioxidant activity, and enzymatic activity of polyphenol oxidase (PPO) were evaluated after high pressure processing (HPP) on a pumpkin purée (cv. 'Butternut'). Three pressure levels (400, 500, and 600 MPa) were combined with three holding times (200, 400, and 600 s). The applied treatments reduced the levels of total aerobic mesophilic (TAM), total psychrophilic and psychrotrophic bacteria (TPP), and molds and yeasts (M&Y). All applied treatments did not affect enzymatic activity of PPO. Pressure level increased CIE L* values, which could enhance the lightness perception of high pressure (HP)-treated purées. No differences were found between the untreated and HP-treated purées regarding total phenols and carotenoids content (lutein, α-carotene, and β-carotene) and total antioxidant activity. HPP did not affect most quality parameters and maintained the levels of bioactive compounds. However, it did not achieve the complete inhibition of PPO, which could reduce the shelf-life of the pumpkin purée. © The Author(s) 2015.

  11. Pressure-driven insulator-metal transition in cubic phase UO2

    Science.gov (United States)

    Huang, Li; Wang, Yilin; Werner, Philipp

    2017-09-01

    Understanding the electronic properties of actinide oxides under pressure poses a great challenge for experimental and theoretical studies. Here, we investigate the electronic structure of cubic phase uranium dioxide at different volumes using a combination of density functional theory and dynamical mean-field theory. The ab initio calculations predict an orbital-selective insulator-metal transition at a moderate pressure of ∼45 GPa. At this pressure the uranium's 5f 5/2 state becomes metallic, while the 5f 7/2 state remains insulating up to about 60 GPa. In the metallic state, we observe a rapid decrease of the 5f occupation and total angular momentum with pressure. Simultaneously, the so-called “Zhang-Rice state”, which is of predominantly 5f 5/2 character, quickly disappears after the transition into the metallic phase.

  12. Kinematic evaluation of patients with total and reverse shoulder arthroplasty during rehabilitation exercises with different loads.

    Science.gov (United States)

    de Toledo, Joelly Mahnic; Loss, Jefferson Fagundes; Janssen, Thomas W; van der Scheer, Jan W; Alta, Tjarco D; Willems, W Jaap; Veeger, DirkJan H E J

    2012-10-01

    Following shoulder arthroplasty, any well-planned rehabilitation program should include muscle strengthening. However, it is not always clear how different external loads influence shoulder kinematics in patients with shoulder prostheses. The objective of this study was to describe shoulder kinematics and determine the contribution of the scapulothoracic joint to total shoulder motion of patients with total and reverse shoulder arthroplasties and of healthy individuals during rehabilitation exercises (anteflexion and elevation in the scapular plane) using different loading conditions (without external load, 1 kg and elastic resistance). Shoulder motions were measured using an electromagnetic tracking device. A force transducer was used to record force signals during loaded conditions using elastic resistance. Statistical comparisons were made using a three-way repeated-measures analysis of variance with a Bonferroni post hoc testing. The scapula contributed more to movement of the arm in subjects with prostheses compared to healthy subjects. The same applies for loaded conditions (1 kg and elastic resistance) relative to unloaded tasks. For scapular internal rotation, upward rotation and posterior tilt no significant differences among groups were found during both exercises. Glenohumeral elevation angles during anteflexion were significantly higher in the total shoulder arthroplasty group compared to the reverse shoulder arthroplasty group. Differences in contribution of the scapula to total shoulder motion between patients with different types of arthroplasties were not significant. However, compared to healthy subjects, they were. Furthermore, scapular kinematics of patients with shoulder arthroplasty was influenced by implementation of external loads, but not by the type of load. Copyright © 2012 Elsevier Ltd. All rights reserved.

  13. Modified swelling pressure apparatus using vapor pressure technique for compacted bentonite

    International Nuclear Information System (INIS)

    Nishimura, Tomoyoshi

    2012-01-01

    to measure swelling pressure in a constant relative humidity environment. A relative humidity was created using salt solutions. The total volume of compacted bentonite was maintained constant during absorption process. Change of swelling pressure with elapsed time and influences of suction value are discussed in this study. In addition, unconfined compression tests were conducted for compacted bentonite with three difference suction values. Deformation of both height and diameter for samples due to change of suction were measured before shear tests. It was observed that all samples were occurred large cracks at failure condition. The shear strengths were determined from stress and strain curves Sodium bentonite was in for this test program. The specimen was statically compacted in rigid steel mold. The modified SWCC apparatus was used for soil-water characteristic curve from 0 kPa to 450 kPa in matric suction ranges. The modified SWCC apparatus consist of a triaxial chamber, air apply system, basement with ceramic filter, drain measurement system and consolidation pressure loading system. The ceramic filter had an air entry value of 500 kPa. Absorption was allowed from the top surface portion of compacted bentonite during swelling under constant volume condition. The swelling pressure was measured over two months. After swelling pressure equilibrium, the SWCC test was performed using axis-translation technique. The vertical deformation and drainage of bentonite were measured during applying ambience positive air pressure. Degree of saturation of compacted bentonite was calculated with suctions. The vapor pressure technique was conducted for high soil suction ranges. The range is from 2.8 MPa to 296 MPa corresponding to from RH 98 % to RH 11 %. The diameter and height of compacted bentonite were directly measured for determination of degree of saturation. The swelling pressure tests were conducted using newly swelling pressure test apparatus. The apparatus consisted

  14. Blood pressure variability and risk of cardiovascular events and death in patients with hypertension and different baseline risks.

    Science.gov (United States)

    Mehlum, Maria H; Liestøl, Knut; Kjeldsen, Sverre E; Julius, Stevo; Hua, Tsushung A; Rothwell, Peter M; Mancia, Giuseppe; Parati, Gianfranco; Weber, Michael A; Berge, Eivind

    2018-01-20

    Blood pressure variability is associated with increased risk of cardiovascular events, particularly in high-risk patients. We assessed if variability was associated with increased risk of cardiovascular events and death in hypertensive patients at different risk levels. The Valsartan Antihypertensive Long-term Use Evaluation trial was a randomized controlled trial of valsartan vs. amlodipine in patients with hypertension and different risks of cardiovascular events, followed for a mean of 4.2 years. We calculated standard deviation (SD) of mean systolic blood pressure from visits from 6 months onward in patients with ≥3 visits and no events during the first 6 months. We compared the risk of cardiovascular events in the highest and lowest quintile of visit-to-visit blood pressure variability, using Cox regression. For analysis of death, variability was analysed as a continuous variable. Of 13 803 patients included, 1557 (11.3%) had a cardiovascular event and 1089 (7.9%) died. Patients in the highest quintile of SD had an increased risk of cardiovascular events [hazard ratio (HR) 2.1, 95% confidence interval (95% CI) 1.7-2.4; P risk of death (HR 1.10, 95% CI 1.04-1.17; P = 0.002). Associations were stronger among younger patients and patients with lower systolic blood pressure, and similar between patients with different baseline risks, except for higher risk of death among patients with established cardiovascular disease. Higher visit-to-visit systolic blood pressure variability is associated with increased risk of cardiovascular events in patients with hypertension, irrespective of baseline risk of cardiovascular events. Associations were stronger in younger patients and in those with lower mean systolic blood pressure. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author(s) 2018. For permissions, please email: journals.permissions@oup.com.

  15. The circumvaginal musculature: correlation between pressure and physical assessment.

    Science.gov (United States)

    McKey, P L; Dougherty, M C

    1986-01-01

    This study assessed two recently developed techniques to assess the circumvaginal musculature (CVM), the CVM Rating Scale and the pressure sensitive intravaginal balloon device (IVBD), and correlated results of the two methods. Thirty women volunteers, aged 20 to 42, were studied. CVM Rating Scale total scores and IVBD maximal contraction variables were measured for resting pressure, rate of rise, maximal pressure, rate of return, and time that a submaximal contraction could be sustained (endurance contraction). Age, parity, self-reported orgasm, self-reported Kegel exercises, and self-reported physical exercise were separately correlated with CVM Rating Scale total scores and IVBD maximal pressure results. A positive significant correlation was found between the CVM Rating Scale total scores and the IVBD maximal contraction results for the variables rate of rise, r = .50, p less than .01, maximum pressure, r = .82, p less than .01, and rate of return, r = .44, p less than .01. Self-reported orgasm had a positive significant correlation to the CVM Rating Scale total scores, rho = .34, p less than .05, and to the IVBD maximal pressure results, r = .52, p less than .01. A positive correlation was found between self-reported physical exercise and the CVM Rating Scale total scores, rho = .31, p less than .05. IBVD maximal pressure results were negatively correlated with age, r = -.34, p less than .05, and parity, r = -.34, p less than .05.

  16. Mean Blood Pressure Assessment during Post-Exercise: Result from Two Different Methods of Calculation

    Directory of Open Access Journals (Sweden)

    Gianmarco Sainas, Raffaele Milia, Girolamo Palazzolo, Gianfranco Ibba, Elisabetta Marongiu, Silvana Roberto, Virginia Pinna, Giovanna Ghiani, Filippo Tocco, Antonio Crisafulli

    2016-09-01

    Full Text Available At rest the proportion between systolic and diastolic periods of the cardiac cycle is about 1/3 and 2/3 respectively. Therefore, mean blood pressure (MBP is usually calculated with a standard formula (SF as follows: MBP = diastolic blood pressure (DBP + 1/3 [systolic blood pressure (SBP – DBP]. However, during exercise this proportion is lost because of tachycardia, which shortens diastole more than systole. We analysed the difference in MBP calculation between the SF and a corrected formula (CF which takes into account changes in the diastolic and systolic periods caused by exercise-induced tachycardia. Our hypothesis was that the SF potentially induce a systematic error in MBP assessment during recovery after exercise. Ten healthy males underwent two exercise-recovery tests on a cycle-ergometer at mild-moderate and moderate-heavy workloads. Hemodynamics and MBP were monitored for 30 minutes after exercise bouts. The main result was that the SF on average underestimated MBP by –4.1 mmHg with respect to the CF. Moreover, in the period immediately after exercise, when sustained tachycardia occurred, the difference between SF and CF was large (in the order of -20-30 mmHg. Likewise, a systematic error in systemic vascular resistance assessment was present. It was concluded that the SF introduces a substantial error in MBP estimation in the period immediately following effort. This equation should not be used in this situation.

  17. Effect of sputter pressure on magnetotransport properties of FePt nanocomposites

    Energy Technology Data Exchange (ETDEWEB)

    Mi, Shu, E-mail: mishu@buaa.edu.cn; Liu, Rui, E-mail: liurui1987@buaa.edu.cn; Li, Yuanyuan, E-mail: buaaliyuan@163.com; Ye, Jun, E-mail: yejun@iphy.ac.cn; Xie, Yong, E-mail: xiey@buaa.edu.cn; Chen, Ziyu, E-mail: chenzy@buaa.edu.cn

    2016-04-01

    FePt films were prepared by magnetron sputtering deposition using Ar as the sputtering gas under different working pressures (0.3–0.7 Pa). The effect of sputtering gas pressure on the microstructure, magnetic, and magnetoresistance properties has been investigated. The results show that the crystallization of FePt films is strongly dependent on the Ar sputter pressure. With the decrease of Ar working pressures, the fct phase forms and the coercivity (Hc) of FePt films rises under the same annealing temperature. As a result, the giant magnetoresistance (GMR) increases by 20% at the room temperature. At 0.7 Pa, the anisotropy magnetoresistance (AMR) can be observed clearly at a low field. However, as the Ar pressure decreases, the increase of GMR leads to a degradation of AMR effect. We believe that the improvement of GMR effect results from the increase of magnetic anisotropy and spin polarization in the process of transformation from the soft magnetic fcc phase to the hard magnetic fct phase. - Highlights: • FePt films were sputtered under different Ar working pressures. • The low Ar pressure promotes the formation of L1{sub 0} phase. • The Hc of FePt films enlarges with the reduction of Ar pressure. • As the Ar pressure decreases, the MR increases by 20%. • The total MR results from the competition of GMR and AMR.

  18. Effect of sputter pressure on magnetotransport properties of FePt nanocomposites

    International Nuclear Information System (INIS)

    Mi, Shu; Liu, Rui; Li, Yuanyuan; Ye, Jun; Xie, Yong; Chen, Ziyu

    2016-01-01

    FePt films were prepared by magnetron sputtering deposition using Ar as the sputtering gas under different working pressures (0.3–0.7 Pa). The effect of sputtering gas pressure on the microstructure, magnetic, and magnetoresistance properties has been investigated. The results show that the crystallization of FePt films is strongly dependent on the Ar sputter pressure. With the decrease of Ar working pressures, the fct phase forms and the coercivity (Hc) of FePt films rises under the same annealing temperature. As a result, the giant magnetoresistance (GMR) increases by 20% at the room temperature. At 0.7 Pa, the anisotropy magnetoresistance (AMR) can be observed clearly at a low field. However, as the Ar pressure decreases, the increase of GMR leads to a degradation of AMR effect. We believe that the improvement of GMR effect results from the increase of magnetic anisotropy and spin polarization in the process of transformation from the soft magnetic fcc phase to the hard magnetic fct phase. - Highlights: • FePt films were sputtered under different Ar working pressures. • The low Ar pressure promotes the formation of L1 0 phase. • The Hc of FePt films enlarges with the reduction of Ar pressure. • As the Ar pressure decreases, the MR increases by 20%. • The total MR results from the competition of GMR and AMR.

  19. The effect of positive end-expiratory pressure on pulse pressure ...

    African Journals Online (AJOL)

    The effect of positive end-expiratory pressure on pulse pressure variation. FJ Smith, M Geyser, I Schreuder, PJ Becker. Abstract. Objectives: To determine the effect of different levels of positive end-expiratory pressure (PEEP) on pulse pressure variation (PPV). Design: An observational study. Setting: Operating theatres of a ...

  20. High-pressure boron hydride phases

    International Nuclear Information System (INIS)

    Barbee, T.W. III; McMahan, A.K.; Klepeis, J.E.; van Schilfgaarde, M.

    1997-01-01

    The stability of boron-hydrogen compounds (boranes) under pressure is studied from a theoretical point of view using total-energy methods. We find that the molecular forms of boranes known to be stable at ambient pressure become unstable at high pressure, while structures with extended networks of bonds or metallic bonding are energetically favored at high pressures. If such structures are metastable on return to ambient pressure, they would be energetic as well as dense hydrogen storage media. An AlH 3 -like structure of BH 3 is particularly interesting in that it may be accessible by high-pressure diamond anvil experiments, and should exhibit both second-order structural and metal-insulator transitions at lower pressures. copyright 1997 The American Physical Society

  1. Pressure Tube and Pressure Vessel Reactors; certain comparisons

    Energy Technology Data Exchange (ETDEWEB)

    Margen, P H; Ahlstroem, P E; Pershagen, B

    1961-04-15

    In a comparison between pressure tube and pressure vessel type reactors for pressurized D{sub 2}O coolant and natural uranium, one can say that reactors of these two types having the same net electrical output, overall thermal efficiency, reflected core volume and fuel lattice have roughly the same capital cost. In these circumstances, the fuel burn-up obtainable has a significant influence on the relative economics. Comparisons of burn-up values made on this basis are presented in this report and the influence on the results of certain design assumptions are discussed. One of the comparisons included is based on the dimensions and ratings proposed for CANDU. Moderator temperature coefficients are compared and differences in kinetic behaviour which generally result in different design philosophies for the two types are mentioned, A comparison of different methods of obtaining flux flattening is presented. The influence of slight enrichment and other coolants, (boiling D{sub 2}O and gases) on the comparison between pressure tube and pressure vessel designs is discussed and illustrated with comparative designs for 400 MW electrical output. This paper was presented at the EAES Enlarged Symposium on Heterogeneous Heavy Water Power Reactors, Mallorca, October 10 - 14, 1960.

  2. Pressure Tube and Pressure Vessel Reactors; certain comparisons

    International Nuclear Information System (INIS)

    Margen, P.H.; Ahlstroem, P.E.; Pershagen, B.

    1961-04-01

    In a comparison between pressure tube and pressure vessel type reactors for pressurized D 2 O coolant and natural uranium, one can say that reactors of these two types having the same net electrical output, overall thermal efficiency, reflected core volume and fuel lattice have roughly the same capital cost. In these circumstances, the fuel burn-up obtainable has a significant influence on the relative economics. Comparisons of burn-up values made on this basis are presented in this report and the influence on the results of certain design assumptions are discussed. One of the comparisons included is based on the dimensions and ratings proposed for CANDU. Moderator temperature coefficients are compared and differences in kinetic behaviour which generally result in different design philosophies for the two types are mentioned, A comparison of different methods of obtaining flux flattening is presented. The influence of slight enrichment and other coolants, (boiling D 2 O and gases) on the comparison between pressure tube and pressure vessel designs is discussed and illustrated with comparative designs for 400 MW electrical output. This paper was presented at the EAES Enlarged Symposium on Heterogeneous Heavy Water Power Reactors, Mallorca, October 10 - 14, 1960

  3. Blood pressure variations in Subjects with different Haemoglobin ...

    African Journals Online (AJOL)

    Dr Olaleye Samuel

    compared with the normal controls. The systolic blood pressures in control (HB AA) and SCD patients were .... especially in older patients and may predispose them to stroke and other ... autonomic responses to change in posture or vitamin C.

  4. Effects of different hydrostatic pressure on lesions in ex vivo bovine livers induced by high intensity focused ultrasound.

    Science.gov (United States)

    He, Min; Zhong, Zhiqiang; Li, Xing; Gong, Xiaobo; Wang, Zhibiao; Li, Faqi

    2017-05-01

    It is well-known that acoustic cavitation associated with the high intensity focused ultrasound (HIFU) treatment often would change the morphology and size of lesions in its treatment. In most studies reported in literature, high ambient hydrostatic pressure was used to suppress the cavitation completely. Investigation of the effects by varying the ambient hydrostatic pressure (P stat ) is still lacking. In this paper, the effects of HIFU on lesions in ex vivo bovine liver specimens under various P stat are systematically investigated. A 1MHz HIFU transducer, with an aperture diameter of 70mm and a focal length of 55mm, was used to generate two groups US exposure of different acoustic intensities and exposure time (6095W/cm 2 ×8s and 9752W/cm 2 ×5s), while keeping the same acoustic energies per unit area (48760J/cm 2 ). The peak acoustic negative pressures (p - ) of the two groups were p 1 - =9.58MPa and p 2 - =10.82MPa, respectively, with the difference p d - =p 2 - -p 1 - =1.24MPa. A passive cavitation detection (PCD) was used to monitor the ultrasonic cavitation signal during exposure of the two groups. The US exposures were done under the following ambient hydrostatic pressures, P stat : atmospheric pressure, 0.5MPa, 1.0MPa, 1.5MPa, 2.0MPa, 2.5MPa and3.0MPa, respectively. The result of PCD showed that there was a statistically significant increase above background noise level in broadband emissions at dose of 9752W/cm 2 ×5s, but not at dose of 6095W/cm 2 ×8s under atmospheric pressure; i.e., the acoustic cavitation took place for p 2 - but not for p 1 - when under atmospheric pressure. The results also showed that there was no statistically difference of the morphology and size of lesions for 6095W/cm 2 ×8s exposure under the aforementioned different ambient hydrostatic pressures. But the lesions generated at 9752W/cm 2 ×5s exposure under P stat =atmospheric pressure, 0.5MPa, 1.0MPa (all of them are less than p d - ), were larger than those under 1.5MPa

  5. Cost analysis of surgically treated pressure sores stage III and IV.

    Science.gov (United States)

    Filius, A; Damen, T H C; Schuijer-Maaskant, K P; Polinder, S; Hovius, S E R; Walbeehm, E T

    2013-11-01

    Health-care costs associated with pressure sores are significant and their financial burden is likely to increase even further. The aim of this study was to analyse the direct medical costs of hospital care for surgical treatment of pressure sores stage III and IV. We performed a retrospective chart study of patients who were surgically treated for stage III and IV pressure sores between 2007 and 2010. Volumes of health-care use were obtained for all patients and direct medical costs were subsequently calculated. In addition, we evaluated the effect of location and number of pressure sores on total costs. A total of 52 cases were identified. Average direct medical costs in hospital were €20,957 for the surgical treatment of pressure sores stage III or IV; average direct medical costs for patients with one pressure sore on an extremity (group 1, n = 5) were €30,286, €10,113 for patients with one pressure sore on the trunk (group 2, n = 32) and €40,882 for patients with multiple pressure sores (group 3, n = 15). The additional costs for patients in group 1 and group 3 compared to group 2 were primarily due to longer hospitalisation. The average direct medical costs for surgical treatment of pressure sores stage III and IV were high. Large differences in costs were related to the location and number of pressure sores. Insight into the distribution of these costs allows identification of high-risk patients and enables the development of specific cost-reducing measures. Copyright © 2013 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  6. The Role of Hyperglycemia, Insulin Resistance, and Blood Pressure in Diabetes-Associated Differences in Cognitive Performance-The Maastricht Study.

    Science.gov (United States)

    Geijselaers, Stefan L C; Sep, Simone J S; Claessens, Danny; Schram, Miranda T; van Boxtel, Martin P J; Henry, Ronald M A; Verhey, Frans R J; Kroon, Abraham A; Dagnelie, Pieter C; Schalkwijk, Casper G; van der Kallen, Carla J H; Biessels, Geert Jan; Stehouwer, Coen D A

    2017-11-01

    To study to what extent differences in cognitive performance between individuals with different glucose metabolism status are potentially attributable to hyperglycemia, insulin resistance, and blood pressure-related variables. We used cross-sectional data from 2,531 participants from the Maastricht Study (mean age ± SD, 60 ± 8 years; 52% men; n = 666 with type 2 diabetes), all of whom completed a neuropsychological test battery. Hyperglycemia was assessed by a composite index of fasting glucose, postload glucose, glycated hemoglobin (HbA 1c ), and tissue advanced glycation end products; insulin resistance by the HOMA of insulin resistance index; and blood pressure-related variables included 24-h ambulatory pressures, their weighted SDs, and the use of antihypertensive medication. Linear regression analyses were used to estimate mediating effects. After adjustment for age, sex, and education, individuals with type 2 diabetes, compared with those with normal glucose metabolism, performed worse in all cognitive domains (mean differences in composite z scores for memory -0.087, processing speed -0.196, executive function and attention -0.182; P values <0.032), whereas individuals with prediabetes did not. Diabetes-associated differences in processing speed and executive function and attention were largely explained by hyperglycemia (mediating effect 79.6% [bootstrapped 95% CI 36.6; 123.4] and 50.3% [0.6; 101.2], respectively) and, for processing speed, to a lesser extent by blood pressure-related variables (17.7% [5.6; 30.1]), but not by insulin resistance. None of the factors explained the differences in memory function. Our cross-sectional data suggest that early glycemic and blood pressure control, perhaps even in the prediabetic stage, may be promising therapeutic targets for the prevention of diabetes-associated decrements in cognitive performance. © 2017 by the American Diabetes Association.

  7. Comparison of Cooling Different Parts in a High Pressure Ratio Centrifugal Compressor

    Directory of Open Access Journals (Sweden)

    S. Mostafa Moosania

    2016-12-01

    Full Text Available Cooling in a centrifugal compressor can improve the performance and reduce the impeller temperature. In a centrifugal compressor, external walls can be cool down, which is known as the shell cooling. This method avoids undesirable effects induced by other cooling methods. Cooling can be applied on different external walls, such as the shroud, diffuser or the back plate. This paper focuses on seeking the most effective cooling place to increase the performance and reduce the impeller temperature. It is found that shroud cooling improves the compressor performance the most. Shroud cooling with 2400 W of cooling power increases the pressure ratio by 4.6% and efficiency by 1.49%. Each 500 W increase in the shroud cooling power, increases the efficiency by 0.3%. Diffuser cooling and back plate cooling have an identical effect on the polytropic efficiency. However, back plate cooling increases the pressure ratio more than diffuser cooling. Furthermore, only back plate cooling reduces the impeller temperature, and with 2400 W of cooling power, the impeller temperature reduces by 45 K.

  8. Racial and Ethnic Differences in Total Knee Arthroplasty in the Veterans Affairs Health Care System, 2001-2013.

    Science.gov (United States)

    Hausmann, Leslie R M; Brandt, Cynthia A; Carroll, Constance M; Fenton, Brenda T; Ibrahim, Said A; Becker, William C; Burgess, Diana J; Wandner, Laura D; Bair, Matthew J; Goulet, Joseph L

    2017-08-01

    To examine black-white and Hispanic-white differences in total knee arthroplasty from 2001 to 2013 in a large cohort of patients diagnosed with osteoarthritis (OA) in the Veterans Affairs (VA) health care system. Data were from the VA Musculoskeletal Disorders cohort, which includes data from electronic health records of more than 5.4 million veterans with musculoskeletal disorders diagnoses. We included white (non-Hispanic), black (non-Hispanic), and Hispanic (any race) veterans, age ≥50 years, with an OA diagnosis from 2001-2011 (n = 539,841). Veterans were followed from their first OA diagnosis until September 30, 2013. As a proxy for increased clinical severity, analyses were also conducted for a subsample restricted to those who saw an orthopedic or rheumatology specialist (n = 148,844). We used Cox proportional hazards regression to examine racial and ethnic differences in total knee arthroplasty by year of OA diagnosis, adjusting for age, sex, body mass index, physical and mental diagnoses, and pain intensity scores. We identified 12,087 total knee arthroplasty procedures in a sample of 473,170 white, 50,172 black, and 16,499 Hispanic veterans. In adjusted models examining black-white and Hispanic-white differences by year of OA diagnosis, total knee arthroplasty rates were lower for black than for white veterans diagnosed in all but 2 years. There were no Hispanic-white differences regardless of when diagnosis occurred. These patterns held in the specialty clinic subsample. Black-white differences in total knee arthroplasty appear to be persistent in the VA, even after controlling for potential clinical confounders. © 2016, American College of Rheumatology.

  9. Age-Related Differences in Motor Coordination during Simultaneous Leg Flexion and Finger Extension: Influence of Temporal Pressure

    OpenAIRE

    Hussein, Tarek; Yiou, Eric; Larue, Jacques

    2013-01-01

    Although the effect of temporal pressure on spatio-temporal aspects of motor coordination and posture is well established in young adults, there is a clear lack of data on elderly subjects. This work examined the aging-related effects of temporal pressure on movement synchronization and dynamic stability. Sixteen young and eleven elderly subjects performed series of simultaneous rapid leg flexions in an erect posture paired with ipsilateral index-finger extensions, minimizing the difference b...

  10. Aortic blood pressure measured via EIT: investigation of different measurement settings.

    Science.gov (United States)

    Braun, Fabian; Proença, Martin; Rapin, Michael; Lemay, Mathieu; Adler, Andy; Grychtol, Bartłomiej; Solà, Josep; Thiran, Jean-Philippe

    2015-06-01

    Electrical impedance tomography (EIT) allows the measurement of intra-thoracic impedance changes related to cardiovascular activity. As a safe and low-cost imaging modality, EIT is an appealing candidate for non-invasive and continuous haemodynamic monitoring. EIT has recently been shown to allow the assessment of aortic blood pressure via the estimation of the aortic pulse arrival time (PAT). However, finding the aortic signal within EIT image sequences is a challenging task: the signal has a small amplitude and is difficult to locate due to the small size of the aorta and the inherent low spatial resolution of EIT. In order to most reliably detect the aortic signal, our objective was to understand the effect of EIT measurement settings (electrode belt placement, reconstruction algorithm). This paper investigates the influence of three transversal belt placements and two commonly-used difference reconstruction algorithms (Gauss-Newton and GREIT) on the measurement of aortic signals in view of aortic blood pressure estimation via EIT. A magnetic resonance imaging based three-dimensional finite element model of the haemodynamic bio-impedance properties of the human thorax was created. Two simulation experiments were performed with the aim to (1) evaluate the timing error in aortic PAT estimation and (2) quantify the strength of the aortic signal in each pixel of the EIT image sequences. Both experiments reveal better performance for images reconstructed with Gauss-Newton (with a noise figure of 0.5 or above) and a belt placement at the height of the heart or higher. According to the noise-free scenarios simulated, the uncertainty in the analysis of the aortic EIT signal is expected to induce blood pressure errors of at least ± 1.4 mmHg.

  11. Aortic blood pressure measured via EIT: investigation of different measurement settings

    International Nuclear Information System (INIS)

    Braun, Fabian; Proença, Martin; Rapin, Michael; Lemay, Mathieu; Solà, Josep; Adler, Andy; Grychtol, Bartłomiej; Thiran, Jean-Philippe

    2015-01-01

    Electrical impedance tomography (EIT) allows the measurement of intra-thoracic impedance changes related to cardiovascular activity. As a safe and low-cost imaging modality, EIT is an appealing candidate for non-invasive and continuous haemodynamic monitoring. EIT has recently been shown to allow the assessment of aortic blood pressure via the estimation of the aortic pulse arrival time (PAT). However, finding the aortic signal within EIT image sequences is a challenging task: the signal has a small amplitude and is difficult to locate due to the small size of the aorta and the inherent low spatial resolution of EIT. In order to most reliably detect the aortic signal, our objective was to understand the effect of EIT measurement settings (electrode belt placement, reconstruction algorithm). This paper investigates the influence of three transversal belt placements and two commonly-used difference reconstruction algorithms (Gauss–Newton and GREIT) on the measurement of aortic signals in view of aortic blood pressure estimation via EIT. A magnetic resonance imaging based three-dimensional finite element model of the haemodynamic bio-impedance properties of the human thorax was created. Two simulation experiments were performed with the aim to (1) evaluate the timing error in aortic PAT estimation and (2) quantify the strength of the aortic signal in each pixel of the EIT image sequences. Both experiments reveal better performance for images reconstructed with Gauss–Newton (with a noise figure of 0.5 or above) and a belt placement at the height of the heart or higher. According to the noise-free scenarios simulated, the uncertainty in the analysis of the aortic EIT signal is expected to induce blood pressure errors of at least ± 1.4 mmHg. (paper)

  12. The Increase of Intra-Abdominal Pressure Can Affect Intraocular Pressure

    Directory of Open Access Journals (Sweden)

    Ilhan Ece

    2015-01-01

    Full Text Available Objective. This study aims to explore the usage of intraocular pressure measurements as the early indicator of the increase in intra-abdominal pressure. Methods. In this prospective study, 40 patients undergoing elective surgery were included. Patients were divided into four groups of 10 patients. The control group (Group C was not subjected to laparoscopic intervention. Laparoscopic surgery was, respectively, performed with an intra-abdominal pressure of 9, 12, and 15 mmHg in Groups L (low, M (medium, and H (high pressure. Intraocular pressure was measured binocularly in each patient at three different times (before, during, and end of surgery using a contact tonometer. Results. Patients’ gender, age, body mass index (BMI, American Society of Anesthesiology (ASA class, and operative times were not different among the groups. No complications occurred with either the surgery or measurement of intraocular pressure. Intubation was associated with a severe rise in IOP (P<0.05. An increase in intraocular pressure was seen in groups M and H (P<0.05. Conclusion. Intraocular pressure was increased in the groups with an intra-abdominal pressure of 12 mmHg or more. Measuring the intraocular pressure might be a useful method to estimate the intra-abdominal pressure. This trial is registered with NCT02319213.

  13. Chemical vapor deposition of hexagonal boron nitride films in the reduced pressure

    International Nuclear Information System (INIS)

    Choi, B.J.

    1999-01-01

    Hexagonal boron nitride (h-BN) films were deposited onto a graphite substrate in reduced pressure by reacting ammonia and boron tribromide at 800--1,200 C. The growth rate of h-BN films was dependent on the substrate temperature and the total pressures. The growth rate increased with increasing the substrate temperature at the pressure of 2 kPa, while it showed a maximum value at the pressures of 4 and 8 kPa. The temperature at which the maximum growth rate occurs decreased with increasing total pressure. With increasing the substrate temperature and total pressure, the apparent grain size increased and the surface morphology showed a rough, cauliflower-like structure

  14. Thermodynamics of the multicomponent vapor-liquid equilibrium under capillary pressure difference

    DEFF Research Database (Denmark)

    Shapiro, Alexander; Stenby, Erling Halfdan

    2001-01-01

    We discuss the two-phase multicomponent equilibrium, provided that the phase pressures are different due to the action of capillary forces. We prove the two general properties of such an equilibrium, which have previously been known for a single-component case, however, to the best of our knowledge......, not for the multicomponent mixtures. The importance is emphasized on the space of the intensive variables P, T and mu (i), where the laws of capillary equilibrium have a simple geometrical interpretation. We formulate thermodynamic problems specific to such an equilibrium, and outline changes to be introduced to common...... algorithms of flash calculations in order to solve these problems. Sample calculations show large variation of the capillary properties of the mixture in the very neighborhood of the phase envelope and the restrictive role of the spinodal surface as a boundary for possible equilibrium states with different...

  15. Total cholesterol and the risk of Parkinson disease.

    Science.gov (United States)

    Hu, G; Antikainen, R; Jousilahti, P; Kivipelto, M; Tuomilehto, J

    2008-05-20

    To examine the association between serum total cholesterol at baseline and the risk of Parkinson disease (PD). Study cohorts included 24,773 Finnish men and 26,153 women aged 25 to 74 years without a history of PD and stroke at baseline. Hazard ratios (HRs) of incident PD were estimated for different levels of total cholesterol. During a mean follow-up period of 18.1 years, 321 men and 304 women developed incident PD. After adjustment for confounding factors (age, study years, body mass index, systolic blood pressure, education, leisure-time physical activity, smoking, alcohol consumption, coffee and tea consumption, and history of diabetes), the HRs of PD at different levels of total cholesterol (or=7 mmol/L) were 1.00, 1.33, 1.53, and 1.84 (p for trend = 0.035) in men; 1.00, 1.55, 1.57, and 1.86 (p for trend = 0.113) in women; and 1.00, 1.42, 1.56, and 1.86 (p for trend = 0.002) in men and women combined (adjusted also for sex). In both sexes combined, the increased risk of PD associated with increasing levels of serum total cholesterol was present both in subjects aged 25-44 years and in subjects aged 45-54 years at baseline, and in never smokers and smokers; however, no association was found among subjects aged 55 years or older at baseline. This large prospective study suggests that high total cholesterol at baseline is associated with an increased risk of Parkinson disease.

  16. Validation of the Rossmax CF175 upper-arm blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol revision 2010.

    Science.gov (United States)

    Zhang, Lu; Kang, Yuan-Yuan; Zeng, Wei-Fang; Li, Yan; Wang, Ji-Guang

    2015-04-01

    The present study aimed to evaluate the accuracy of the Rossmax CF175 upper-arm blood pressure monitor for home blood pressure monitoring according to the International Protocol of the European Society of Hypertension revision 2010. Systolic and diastolic blood pressures were sequentially measured in 33 adult Chinese (17 women, mean age 46 years) using a mercury sphygmomanometer (two observers) and the Rossmax CF175 device (one supervisor). A total of 99 pairs of comparisons were obtained from 33 participants for judgments in two parts with three grading phases. All the blood pressure requirements were fulfilled. The Rossmax CF175 device achieved the targets in part 1 of the validation study. The number of absolute differences between the device and observers within 5, 10, and 15 mmHg was 78/99, 94/99, and 98/99, respectively, for systolic blood pressure, and 81/99, 96/99, and 97/99, respectively, for diastolic blood pressure. The device also achieved the criteria in part 2 of the validation study. Twenty-nine participants, for both of systolic and diastolic blood pressure, had at least two of the three device-observers differences within 5 mmHg (required ≥24). Only one participant for diastolic blood pressure had all three device-observers comparisons greater than 5 mmHg. The Rossmax automated oscillometric upper-arm blood pressure monitor CF175 fulfilled the requirements of the International Protocol revision 2010, and hence can be recommended for blood pressure measurement in adults.

  17. The Pacman Perforator-Based V-Y Advancement Flap for Reconstruction of Pressure Sores at Different Locations.

    Science.gov (United States)

    Bonomi, Stefano; Salval, André; Brenta, Federica; Rapisarda, Vincenzo; Settembrini, Fernanda

    2016-09-01

    Many procedures have been proposed for the treatment of pressure sores, and V-Y advancement flaps are widely used to repair a defect. Unfortunately, the degree of mobility of a V-Y advancement flap is dependent on the laxity of the underlying subcutaneous tissue. This is an important disadvantage of traditional V-Y advancement flap and limits its use.We used V-Y advancement flaps as perforator-based to overcome mobility restriction problem, with a further modification (Pacman-like shape) to improve the covering surface area of the flap. Between January 2012 and December 2014, the authors used 37 V-Y Pacman perforator-based flaps in 33 consecutive patients for coverage of defects located at sacral (n = 21), ischial (n = 13), trochanter (n = 1) regions. There were 27 male and 6 female patients with a mean age of 49.9 years (range, 15-74 years). All flaps survived completely (92.3%) except 3 in which one of them had undergone total necrosis due to hematoma and the other 2 had partial necrosis. No venous congestion was observed. The mean follow-up period was 14.9 months (range, 2-38 months). No flap surgery-related mortality or recurrence of pressure sores was noted. The V-Y Pacman perforator-based advancement flaps are safe and very effective for reconstruction of pressure sores at various regions. The advantage of our modification procedure include shorter operative time, lesser pedicle dissection, low donor site morbidity, good preservation of muscle, and offers remarkable excursion to the V-Y flap, which make the V-Y Pacman perforator-based flaps an excellent choice for large pressure sore coverage.

  18. Large-scale retrospective evaluation of regulated liquid chromatography-mass spectrometry bioanalysis projects using different total error approaches.

    Science.gov (United States)

    Tan, Aimin; Saffaj, Taoufiq; Musuku, Adrien; Awaiye, Kayode; Ihssane, Bouchaib; Jhilal, Fayçal; Sosse, Saad Alaoui; Trabelsi, Fethi

    2015-03-01

    The current approach in regulated LC-MS bioanalysis, which evaluates the precision and trueness of an assay separately, has long been criticized for inadequate balancing of lab-customer risks. Accordingly, different total error approaches have been proposed. The aims of this research were to evaluate the aforementioned risks in reality and the difference among four common total error approaches (β-expectation, β-content, uncertainty, and risk profile) through retrospective analysis of regulated LC-MS projects. Twenty-eight projects (14 validations and 14 productions) were randomly selected from two GLP bioanalytical laboratories, which represent a wide variety of assays. The results show that the risk of accepting unacceptable batches did exist with the current approach (9% and 4% of the evaluated QC levels failed for validation and production, respectively). The fact that the risk was not wide-spread was only because the precision and bias of modern LC-MS assays are usually much better than the minimum regulatory requirements. Despite minor differences in magnitude, very similar accuracy profiles and/or conclusions were obtained from the four different total error approaches. High correlation was even observed in the width of bias intervals. For example, the mean width of SFSTP's β-expectation is 1.10-fold (CV=7.6%) of that of Saffaj-Ihssane's uncertainty approach, while the latter is 1.13-fold (CV=6.0%) of that of Hoffman-Kringle's β-content approach. To conclude, the risk of accepting unacceptable batches was real with the current approach, suggesting that total error approaches should be used instead. Moreover, any of the four total error approaches may be used because of their overall similarity. Lastly, the difficulties/obstacles associated with the application of total error approaches in routine analysis and their desirable future improvements are discussed. Copyright © 2015 Elsevier B.V. All rights reserved.

  19. Colloid osmotic pressure during and after surgical interventions in adult and geriatric dogs

    Directory of Open Access Journals (Sweden)

    Mario A.F. Rego

    Full Text Available ABSTRACT: The objective this study is to evaluate colloid osmotic pressure (COP fluctuations in adult and senile dogs during surgical interventions. Thirty-six healthy dogs to surgical interventions, distributed in two groups, A and B, according to their age, and were all subjected to the same anesthetic protocol. Values of albumin, total plasmatic protein and COP were evaluated from samples collected before pre-anesthetic medication, fifteen minutes after pre-anesthetic medication, and shortly after the end of the intervention. Results were tested using t-test to compare among groups and ANOVA for repeated measures followed by Tukey’s test to compare different moments within the same group. Statistical significance was set at p<0.05. In both groups, significant decreases were observed in colloid osmotic pressure, as well as albumin and total proteins (p<0.001. Despite slightly lower COP values for the group of adult animals, this difference was not significant as there was a high individual variation within groups. The results therefore indicate no difference in colloid osmotic pressure values or fluctuation patterns among adult and senile dogs (p=0.124. The observed results indicate that colloid osmotic pressure decreases significantly during surgical procedures, due to hypotension caused by the anesthetic drugs and to hemodilution caused by the fluid administration but there is no difference between groups. However, in both adult and senile dogs, these variables recover gradually after the animals awaken, through increased urine production and recovery of vascular tonus, indicating the successful reestablishment of homeostasis.

  20. Oxygen consumption in EPDM irradiated under different oxygen pressures and at different LET

    International Nuclear Information System (INIS)

    Dely, N.; Ngono-Ravache, Y.; Ramillon, J.-M.; Balanzat, E.

    2005-01-01

    We conceived a novel set-up for measuring the radiochemical yields of oxygen consumption in polymers. The measurement is based on a sampling of the gas mixture with a mass spectrometer, before and after irradiation. We irradiated an ethylene, propylene and 1,4-hexadiene terpolymer (EPDM) with 1 MeV electron and 10.75 MeV/A carbon beams. Samples were irradiated under oxygen within a wide range of pressure (5-200 mbar). The yields under C irradiation are four times smaller than the yields under electron irradiation. This shows that radiooxidation is very sensitive to the linear energy transfer of the projectiles and hence to the heterogeneity of the energy deposition. The oxygen consumption yields do not vary significantly in the range of pressure investigated; even at 5 mbar, the kinetics is still governed by the bimolecular recombination of peroxy radicals

  1. [Experimental research of gaits based on young plantar pressure test].

    Science.gov (United States)

    Meng, Qingyun; Tan, Shili; Yu, Hongliu; Shen, Lixing; Zhuang, Jianhai; Wang, Jinwu

    2014-10-01

    The present paper is to study the center line of the plantar pressure of normal young people, and to find the relation between center line of the plantar pressure and gait stability and balance. The paper gives the testing principle and calculating methods for geometric center of plantar pressure distribution and the center of pressure due to the techniques of footprint frame. The calculating formulas in both x direction and y direction are also deduced in the paper. In the experiments carried out in our laboratory, the gait parameters of 131 young subjects walking as usual speed were acquired, and 14 young subjects of the total were specially analyzed. We then provided reference data for the walking gait database of young people, including time parameters, space parameters and plantar pressure parameters. We also obtained the line of geometry center and pressure center under the foot. We found that the differences existed in normal people's geometric center line and the pressure center line. The center of pressure trajectory revealed foot movement stability. The length and lateral changes of the center line of the plantar pressure could be applied to analysis of the plantar pressure of all kinds of people. The results in this paper are useful in clinical foot disease diagnosis and evaluation of surgical effect.

  2. Numerical investigation on pressure fluctuations in centrifugal compressor with different inlet guide vanes pre-whirl angles

    Science.gov (United States)

    Wang, Y. C.; Shi, M.; Cao, S. L.; Li, Z. H.

    2013-12-01

    The pressure fluctuations in a centrifugal compressor with different inlet guide vanes (IGV) pre-whirl angles were investigated numerically, as well as the pre-stress model and static structural of blade. The natural frequency was evaluated by pre-stress model analysis. The results show that, the aero-dynamic pressure acting on blade surface is smaller than rotation pre-stress, which wouldn't result in large deformation of blade. The natural frequencies with rotation pre-stress are slightly higher than without rotation pre-stress. The leading mechanism of pressure fluctuations for normal conditions is the rotor-stator (IGVs) interaction, while is serious flow separations for conditions that are close to surge line. A few frequency components in spectra are close to natural frequency, which possibly result in resonant vibration if amplitude is large enough, which is dangerous for compressor working, and should be avoided.

  3. [Peroxynitrite effect on the haemoglobin oxygen affinity in vitro in presence of different partial pressure of carbon dioxide].

    Science.gov (United States)

    Stepuro, T L; Zinchuk, V V

    2011-08-01

    Peroxynitrite (ONOO-) besides its toxic possesses regulatory action that includes the modulation of oxygen binding properties of blood. The aim of this work was to estimate ONOO- effect on the haemoglobin oxygen affinity (HOA) in vitro in presence of different partial pressure of carbon dioxide (CO2). The ONOO- presence in venous blood in conditions of hypercapnia induced oxyhaemoglobin dissociation curve shift leftward while in hypocapnic conditions the result of a different character was obtained. The revealed effect of ONOO- is realized, possibly, through various modifications ofhaemoglobin whose formation is dependent on the CO2 pressure. The ONOO- influences the HOA in different manner that can be important in regulation of blood oxygenation in lungs and maintenance of oxygen consumption in tissues.

  4. Development of gait segmentation methods for wearable foot pressure sensors.

    Science.gov (United States)

    Crea, S; De Rossi, S M M; Donati, M; Reberšek, P; Novak, D; Vitiello, N; Lenzi, T; Podobnik, J; Munih, M; Carrozza, M C

    2012-01-01

    We present an automated segmentation method based on the analysis of plantar pressure signals recorded from two synchronized wireless foot insoles. Given the strict limits on computational power and power consumption typical of wearable electronic components, our aim is to investigate the capability of a Hidden Markov Model machine-learning method, to detect gait phases with different levels of complexity in the processing of the wearable pressure sensors signals. Therefore three different datasets are developed: raw voltage values, calibrated sensor signals and a calibrated estimation of total ground reaction force and position of the plantar center of pressure. The method is tested on a pool of 5 healthy subjects, through a leave-one-out cross validation. The results show high classification performances achieved using estimated biomechanical variables, being on average the 96%. Calibrated signals and raw voltage values show higher delays and dispersions in phase transition detection, suggesting a lower reliability for online applications.

  5. Geographical differences in the relationship between total dissolved ...

    African Journals Online (AJOL)

    on the Department of Water Affairs water quality database. ... Keywords: conversion factors, electrical conductivity, field instruments, rivers, total dissolved solids, water quality ... of a number of TDS:EC ratios in samples where both measure-.

  6. Exercise capacity in young adults with hypertension and systolic blood pressure difference between right arm and leg after repair of coarctation of the aorta.

    Science.gov (United States)

    Instebø, Arne; Norgård, Gunnar; Helgheim, Vegard; Røksund, Ola Drange; Segadal, Leidulf; Greve, Gottfried

    2004-10-01

    Coarctation of the aorta represents 5-7% of congenital heart defects. Symptoms and prognosis depend on the degree of stenosis, age at surgery, surgical method and the presence of other heart defects. Postoperative complications are hypertension, restenosis and an abnormal blood pressure response during exercise. This study includes 41 patients, 15-40 years old, operated in the period 1975-1996. All were exercised on a treadmill until maximal oxygen consumption was achieved. Blood pressure was measured in the right arm and leg before and immediately after exercise, and in the right arm during exercise. Oxygen consumption was monitored and we defined an aerobic phase, an isocapnic buffering phase and a hypocapnic hyperventilation phase. The resting systolic blood pressure correlates with the resting systolic blood pressure difference between right arm and leg. A resting systolic blood pressure difference between the right arm and leg of 0.13 kPa (1 mmHg) to 2.67 kPa (20 mmHg) corresponds with a slight increase in resting systolic blood pressure. This rise in blood pressure increases the aerobic phase of the exercise test, helping the patients to achieve higher maximal oxygen consumption. A resting systolic blood pressure difference of more than 2.67 kPa (20 mmHg) corresponds with severe hypertension and causes reduction in the aerobic phase and maximal oxygen consumption. Resting systolic blood pressure and resting systolic blood pressure difference between the right arm and leg are not indicators for blood pressure response during exercise. Exercise testing is important to reveal exercise-induced hypertension and to monitor changes in transition from aerobic to anaerobic exercise and limitation to exercise capacity.

  7. Sputtering in a glow discharge ion source - pressure dependence: theory and experiment

    International Nuclear Information System (INIS)

    Mason, R.S.; Pichilingi, Melanie

    1994-01-01

    A simplified theoretical expression has been developed for a glow discharge to show how the average cathode erosion rate (expressed as the number of atoms per ion of the total bombarding flux) varies with primary sputter yield, pressure, 'diffusion length' and sputtered atom 'stopping' cross section. An inverse pressure dependence is predicted which correlates well with experiment in the 2 and He, tend to converge. It is suggested that this could be due to a change in the mechanism to self-sputtering. Under constant conditions, the erosion rates of different cathode materials still correlate quite well with the differences in their primary sputter yields. (author)

  8. Prevalence of systolic inter-arm differences in blood pressure for different primary care populations: systematic review and meta-analysis.

    Science.gov (United States)

    Clark, Christopher E; Taylor, Rod S; Shore, Angela C; Campbell, John L

    2016-11-01

    Various prevalence figures have been reported for inter-arm differences in blood pressure (IAD); variation may be explained by differing population vascular risk and by measurement method. To review the literature to derive robust estimates of IAD prevalence relevant to community populations. Systematic review and meta-analysis. MEDLINE, Embase, and CINAHL were searched for cross-sectional studies likely to represent general or primary care populations, reporting prevalence of IAD and employing a simultaneous method of measurement. Using study-level data, pooled estimates of mean prevalence of systolic IADs were calculated and compared using a random effects model. Eighty IAD studies were identified. Sixteen met inclusion criteria: pooled estimates of prevalence for systolic IAD ≥10 mmHg were 11.2% (95% confidence interval [CI] = 9.1 to 13.6) in hypertension, 7.4% (95% CI = 5.8 to 9.2) in diabetes, and 3.6% (95% CI = 2.3 to 5.0) for a general adult population (Pdifferences). Differences persisted for higher cut-off values. Prevalences were lower for East Asian than for Western populations and were overestimated by sequential measurement where this could be compared with simultaneous measurement within studies (relative risk for IAD: 2.9 [95% CI = 2.1 to 4.1]). Studies with higher mean absolute systolic pressures had higher prevalences for a systolic IAD ≥10 mmHg (P = 0.04). Prevalences of IADs rise in relation to underlying cardiovascular comorbidities of the population studied, and are overestimated threefold when sequential measurement is used. Population-specific variation in prevalences of IAD should be taken into account in delivering clinical care and in planning future studies. © British Journal of General Practice 2016.

  9. Interarm differences in systolic blood pressure and mortality among US army veterans

    DEFF Research Database (Denmark)

    White, James; Mortensen, Laust Hvas; Kivimäki, Mika

    2014-01-01

    BACKGROUND: Differences between the arms in systolic blood pressure (SBP) of ≥10 mmHg have been associated with an increased risk of mortality in patients with hypertensive and chronic renal disease. For the first time, we examined these relationships in a non-clinical population. DESIGN: Cohort...... an interarm difference of ≥10 and 2.4% of ≥15 mmHg. A 15-year follow-up period gave rise to 246 deaths (64 from cardiovascular disease, CVD). Interarm differences of ≥10 mmHg were associated with an elevated risk of all-cause mortality (hazard ratio, HR, 1.49, 95% confidence interval, CI, 1.04-2.14) and CVD...... mortality (HR 1.93, 95% CI 1.01-3.69). After adjusting for SBP, DBP, lipids, fasting glucose, and erythrocyte sedimentation rate, associations between interarm differences of ≥10 mmHg and all-cause mortality (HR 1.35, 95% CI 0.94-1.95) and CVD mortality (1.62, 95% CI 0.84-3.14) were significantly attenuated...

  10. Acoustic performance of low pressure axial fan rotors with different blade chord length and radial load distribution

    Science.gov (United States)

    Carolus, Thomas

    The paper examines the acoustic and aerodynamic performance of low-pressure axial fan rotors with a hub/tip ratio of 0.45. Six rotors were designed for the same working point by means of the well-known airfoil theory. The condition of an equilibrium between the static pressure gradient and the centrifugal forces is maintained. All rotors have unequally spaced blades to diminish tonal noise. The rotors are tested in a short cylindrical housing without guide vanes. All rotors show very similar flux-pressure difference characteristics. The peak efficiency and the noise performance is considerably influenced by the chosen blade design. The aerodynamically and acoustically optimal rotor is the one with the reduced load at the hub and increased load in the tip region under satisfied equilibrium conditions. It runs at the highest aerodynamic efficiency, and its noise spectrum is fairly smooth. The overall sound pressure level of this rotor is up to 8 dB (A) lower compared to the other rotors under consideration.

  11. Different but Equal: Total Work, Gender and Social Norms in EU and US Time Use

    OpenAIRE

    Daniel S Hamermesh; Michael C Burda; Philippe Weil

    2008-01-01

    Using time-diary data from 27 countries, we demonstrate a negative relationship between real GDP per capita and the female-male difference in total work time—the sum of work for pay and work at home. We also show that in rich non-Catholic countries on four continents men and women do the same amount of total work on average. Our survey results demonstrate that labor economists, macroeconomists, sociologists and the general public consistently believe that women perform more tot...

  12. Intravenous clonidine administration and its ability to reduce pulmonary arterial pressure in patients undergoing heart surgery

    Directory of Open Access Journals (Sweden)

    Benedito Barbosa João

    2014-01-01

    Full Text Available Objective: Evaluate the ability of clonidine to reduce pulmonary arterial pressure in patients with pulmonary hypertension undergoing heart surgery, either by reducing the pressure values from the direct measurement of pulmonary arterial pressure or by reducing or eliminating the need for intraoperative dobutamine and nitroprusside. Method: Randomized, double-blind, placebo-controlled, comparative study conducted in 30 patients with pulmonary arterial hypertension type 2 undergoing cardiac surgery. Mean pulmonary arterial pressure and dosage of dobutamine and sodium nitroprusside were assessed four times: before intravenous administration of clonidine (2 μg/kg or placebo (T0, 30 min after tested treatment and before cardiopulmonary bypass (T1, immediately after CPB (T2, 10 min after protamine injection (T3. Results: There were no significant differences regarding mean pulmonary arterial pressure at any time of evaluation. There was no significant difference between groups regarding other variables, such as mean systemic arterial pressure, heart rate, total dose of dobutamine, total dose of sodium nitroprusside, and need for fentanyl. Conclusion: Data analysis from patients included in this study allows us to conclude that intravenous clonidine (2 μg/kg was not able to reduce the mean pulmonary arterial pressure in patients with pulmonary hypertension in group 2 (pulmonary venous hypertension, undergoing heart surgery, or reduce or eliminate the need for intraoperative administration of dobutamine and sodium nitroprusside. Keywords: Clonidine, Pulmonary hypertension, Heart surgery

  13. One arm exercise induces significant interarm diastolic blood pressure difference.

    Science.gov (United States)

    Hong, Dezhi; Wang, Jiwei; Su, Hai; Xu, Jingsong; Liu, Yanna; Peng, Qiang; Wang, Lijuan

    2011-06-01

    This study is designed to investigate the inducing effect of one arm exercise on interarm difference (IAD) in the blood pressure (BP). Fifty healthy young participants were included in the study. Three-minute exercises of the right arm elbow flexion and extension were performed. The bilateral brachial BP was simultaneously measured with two automatic BP measurement devices before (basic) and immediately 0, 5, 10, 15, 20, and 30 min after exercise. The absolute difference in the systolic BP (SBP) and diastolic BP (DBP) between the left and right BP of at least 10 mmHg was recognized as sIAD and dIAD. The baseline data of the SBP and DBP in left and right arms revealed no significant difference (SBP: 110 ± 10 vs. 111 ± 11 mmHg; DBP: 66 ± 8 vs. 66 ± 9 mmHg, both not significant). The prevalence of dIAD was 2% at the baseline. However, this prevalence increased to 80% at 0 min, as right arm exercise induced the right DBP decrease and left DBP increase, and then the prevalence decreased gradually within a 30-min recovery period. The prevalence of sIAD was zero at the baseline and the maximal prevalence was 8% during the 20-min postexercise period. One arm exercise can lead to a significant IAD in DBP. Any arm exercise should be avoided before BP measurement.

  14. Numerical prediction of pressure loss of fluid in a T-junction

    Energy Technology Data Exchange (ETDEWEB)

    Abdulwahhab, Mohammed; Kumar Injeti, Niranjan [Department of Marin Engineering, Andhra University, AP (India); Fahad Dakhil, Sadoun [Department of Fuel and Energy, Basrah Technical College (Iraq)

    2013-07-01

    This work presents a prediction of pressure loss of fluid with turbulent incompressible flow through a 90° tee junction was carried out and compared with analytical and experimental results. One turbulence model was used in the numerical simulations: {kappa}-{epsilon} model for two different values of area ratio between the main pipe and the branch pipe were 1.0 and 4.0, and flow rate ratios. The continuity, momentum and energy equations were discredited by means of a finite volume technique and the SIMPLE algorithm scheme was applied to link the pressure and velocity fields inside the domain. A three dimensional steady state flow was solving by using CFX 5 code ANSYS FLUENT13. The effect of the flow rate ratio q (ratio between the flow rate in the branch and outlet pipes) on pressure drop and velocity profile was predicted at different Reynolds numbers. The results show that increasing the flow rate ratio the pressure and total energy losses increase because the presence of recirculation and the strong streamline curvature.

  15. Hemolysis During Open-Heart Surgery With Vacuum-Assisted Venous Drainage at Different Negative Pressures in Pediatric Patients Weighing Less Than 10 kilograms.

    Science.gov (United States)

    Kwak, Jae Gun; Lee, Jinkwon; Park, Minkyoung; Seo, Yu-Jin; Lee, Chang-Ha

    2017-03-01

    This study examined the degree of hemolysis during vacuum-assisted venous drainage at different negative pressures to identify an adequate negative pressure that provides effective venous drainage without significant hemolysis in open-heart surgery in children weighing less than 10 kg. Patients weighing less than 10 kg who underwent surgery for ventricular septal defect or atrial septal defect from 2011 to 2014 were enrolled. We used one of four negative pressures (20, 30, 40, or 60 mm Hg) for each patient. We measured haptoglobin, plasma hemoglobin, aspartate aminotransferase, and lactate dehydrogenase levels in the patients' blood three times perioperatively and determined the potential correlation between the change in each parameter with the level of negative pressure. Forty-six patients were enrolled in this study (mean age: 7.1 ± 7.0 months, mean body weight: 6.1 ± 1.8 kg). There were no significant differences according to the degree of negative pressure with respect to patient age, body weight, cardiopulmonary bypass (CPB) time, aorta cross-clamping time, blood flow during CPB, or lowest body temperature. All parameters that we measured reflected progression of hemolysis during CPB; however, the degree of change in the parameters did not correlate with negative pressure. In pediatric patients weighing less than 10 kg, the change in the degree of hemolysis did not differ with the amount of negative pressure. We may apply negative pressures up to 60 mm Hg without increasing the risk of hemolysis, with almost same the level of hemolysis using negative pressures of 20, 30, and 40 mm Hg for effective venous drainage and an ideal operative field during open-heart surgery.

  16. Total hepatofugal portal blood flow in cirrhosis demonstrated by transhepatic portography

    Energy Technology Data Exchange (ETDEWEB)

    Burcharth, F; Aagaard, J

    1988-01-01

    We investigated 108 patients with cirrhosis of the liver and portal hypertension by percutaneous transhepatic portography to demonstrate the occurrence and frequency of total hepatofugal portal blood flow. Sixteen patients (14.8%) had a total hepatofugal portal blood flow. The aetiology of portal hypertension and the portal pressure did not differ from that in the group of patients with hepatopetal portal blood flow. A significantly higher percentage of patients in the group with hepatofugal flow had gastro-oesophageal varices (P < 0.025). All patients with varices had bled. Half of the patients in the group with hepatofugal blood flow had a false splenoportographic diagnosis of portal vein thrombosis. In conclusion, total hepatofugal postal blood flow exists more often than hitherto assumed. Hepatofugal blood flow does not relieve portal hypertension nor prevent development of gastro-oesophageal varices or bleeding.

  17. Desirability of oysters treated by high pressure processing at different temperatures and elevated pressures

    Science.gov (United States)

    Organoleptic changes in sterile triploid oysters (Crassostrea virginica) induced by high pressure processing (HPP) were investigated using a volunteer panel. Using a 1-7 hedonic scale, where seven is “like very much”, and one is “dislike very much”, oysters were evaluated organoleptically for flavo...

  18. The inter-arm systolic blood pressure difference and risk of cardiovascular mortality: A meta-analysis of cohort studies.

    Science.gov (United States)

    Zhou, Ming; Gao, Zhen; Chen, Fei; Xu, Haijun; Dong, Xiao; Ma, Li

    2016-01-01

    The inter-arm systolic blood pressure difference (SBPD) is recommended to be in relation to potential cardiovascular disease (CVD). Previous studies yielded controversial results about the association between an inter-arm SBPD ≥ 10 mmHg or ≥15 mmHg and the risk of cardiovascular mortality. Therefore, we conducted this meta-analysis to investigate this association. We searched PubMed and Embase databases through December 31, 2014, and examined the references of retrieved articles to identify relevant cohort studies. We utilized Newcastle-Ottawa scale to assess the quality of included studies and calculated the summary risk estimates in a fixed/random-effect model. All data analyses were conducted using STATA version 11.0. A total of seven studies were identified. Compared with participants with an inter-arm SBPD arm SBPD ≥ 10 mmHg was 1.58 (95% CI: 1.3-1.93), and the pooled HR of cardiovascular mortality of participants with an inter-arm SBPD ≥ 15 mmHg versus those with an inter-arm SBPD arm SBPD may define a subpopulation at high risk of CVD events.

  19. No clinical difference between large metal-on-metal total hip arthroplasty and 28-mm-head total hip arthroplasty?

    NARCIS (Netherlands)

    Zijlstra, Wierd P; van den Akker-Scheek, Inge; Zee, Mark J M; van Raay, Jos J A M

    2011-01-01

    PURPOSE: We aimed to test the claim of greater range of motion (ROM) with large femoral head metal-on-metal total hip arthroplasty. METHODS: We compared 28-mm metal-on-polyethylene (MP) total hip arthroplasty with large femoral head metal-on-metal (MM) total hip arthroplasty in a randomised clinical

  20. Effects of initiating anaerobic digestion of layer-hen poultry dung at sub-atmospheric pressure

    Directory of Open Access Journals (Sweden)

    Chima C. Ngumah

    2013-12-01

    Full Text Available This study investigated the effects of initiating anaerobic digestion (AD of dry layer-hen poultry dung at the sub-atmospheric pressure of -30 cmHg on biodegradation, biogasification, and biomethanation. The setup was performed as a batch process at an average ambient temperature of 29±2 0C and a retention time of 15 days. Comparisons were made with two other experiments which were both begun at ambient atmospheric pressure; one was inoculated with digestate from a previous layer-hen dung AD, while the other was not inoculated. The bioreactors initiated at sub-atmospheric pressure, ambient atmospheric pressure without inoculum, and ambient atmospheric pressure with inoculum showed the following for biogas and biomethane yields respectively: 16.8 cm3 g-1 VS and 15.46 cm3 g 1 VS, 25.10 cm3 g-1 VS and 12.85 cm3 g-1 VS, 21.44 cm3 g-1 VS and 14.88 cm3 g 1 VS. In the same order, after AD, the following values were recorded for volatile solids and total viable counts (prokaryotes and fungi in the digestates: 40.33% and 23.22 x 106 cfu mL-1, 43.42% and 22.17 x 106 cfu mL-1, 41.11% and 13.3 x 106 cfu mL-1. The feedstock showed values of 83.93% and 3.98 x 106 cfu mL-1 for volatile solids and total viable count respectively. There was a slight difference in the volatile solids of the digestates of the three bioreactors after AD. The pH recorded for the feedstock slurry before AD was 7.9 at 30oC, while after AD, the digestates from all the three bioreactors showed the same pH of 5.9 at 29 0C. Statistical analysis using ANOVA showed no significant difference in biogas yields of the feedstock for the three bioreactors (A, B, C. ANOVA showed no significant difference for biomethane yields in the bioreactors initiated at sub-atmospheric pressure and for those initiated at ambient atmospheric pressure with inoculums. However, it showed significant difference in the bioreactor initiated at sub-atmospheric pressure and that initiated at ambient atmospheric

  1. Cavitation erosion of silver plated coating at different temperatures and pressures

    Energy Technology Data Exchange (ETDEWEB)

    Hattori, Shuji; Motoi, Yoshihiro [Graduate School of Engineering, University of Fukui, 3-9-1 Bunkyo, Fuku-shi, Fukui 910-8507 (Japan); Kikuta, Kengo; Tomaru, Hiroshi [IHI Corperation, TOYOSU IHI BUILDING, 1-1, Toyosu 3-chome, Koto-ku, Tokyo 1358710 (Japan)

    2014-04-11

    Cavitation often occurs in inducer pumps used for space rockets. Silver plated coating on the inducer liner faces the damage of cavitation. Therefore, it is important to study about the cavitation erosion resistance for silver plated coating at several operating conditions in the inducer pumps. In this study, the cavitation erosion tests were carried for silver plated coating in deionized water and ethanol at several liquid temperatures (273K–400K) and pressures (0.10MPa–0.48MPa). The mass loss rate is evaluated in terms of thermodynamic parameter Σ proposed by Brennen [9], suppression pressure p–p{sub v} (p{sub v}: saturated vapor pressure) and acoustic impedance ρc (ρ: density and c: sound speed). Cavitation bubble behaviors depending on the thermodynamic effect and the liquid type were observed by high speed video camera. The mass loss rate is formulated by thermodynamic parameter Σ, suppression pressure p–p{sub v} and acoustic impedance ρc.

  2. Effects of different block size distributions in pressure transient response of naturally fractured reservoirs

    Energy Technology Data Exchange (ETDEWEB)

    Montazeri, G.H. [Islamic Azad University, Mahshahr (Iran, Islamic Republic of). Dept. of Chemical and Petroleum Engineering], E-mail: montazeri_gh@yahoo.com; Tahami, S.A. [Mad Daneshgostar Tabnak Co. (MDT),Tehran (Iran, Islamic Republic of); Moradi, B.; Safari, E. [Iranian Central Oil Fields Co, Tehran (Iran, Islamic Republic of)], E-mail: morady.babak@gmail.com

    2011-07-15

    This paper presents a model for pressure transient and derivative analysis for naturally fractured reservoirs by a formulation of inter porosity flow incorporating variations in matrix block size, which is inversely related to fracture intensity. Geologically realistic Probability Density Functions (PDFs) of matrix block size, such as uniform, bimodal, linear and exponential distributions, are examined and pseudo-steady-state and transient models for inter porosity flow are assumed. The results have been physically interpreted, and, despite results obtained by other authors, it was found that the shape of pressure derivative curves for different PDFs are basically identical within some ranges of block size variability, inter porosity skin, PDFs parameters and matrix storage capacity. This tool can give an insight on the distribution of block sizes and shapes, together with other sources of information such as Logs and geological observations. (author)

  3. A discussion of hyperbolicity in CATHENA 4. Virtual mass and phase-to-interface pressure differences

    International Nuclear Information System (INIS)

    Aydemir, Nusret U.

    2012-01-01

    It is well known that the one-dimensional equations of motion for two-phase flow are non-hyperbolic. Non-hyperbolicity can lead to numerical instabilities, destroying the solution. However, researchers in the last few decades were able to show that inclusion of virtual mass and/or phase-to-interface pressure differences in the momentum equations successfully render the equations of motion hyperbolic. In the present paper, the effect of including virtual mass and phase-to-interface pressure terms in the momentum equations on the hyperbolicity of the two-phase model in the CATHENA 4 code is discussed. The study is motivated by the fact that the inclusion of either model has been shown in the open literature to lead to a hyperbolic system separately. However, no known study exists that examine hyperbolicity in the presence of both these terms in the momentum equations. In this work, both terms are considered in the model equations simultaneously and their implications on the hyperbolicity of the two-phase model are discussed. Specifically, it is shown that in the case of mixed flow, there is a distinct region of non-hyperbolicity that developers need to be aware of when their equations include both the virtual mass and the phase-to-interface terms. Selecting the coefficients of phase-to-interface pressure difference terms properly ensures that the equations are hyperbolic for a wide range of conditions. (orig.)

  4. Numerical investigation on pressure fluctuations in centrifugal compressor with different inlet guide vanes pre-whirl angles

    International Nuclear Information System (INIS)

    Wang, Y C; Shi, M; Cao, S L; Li, Z H

    2013-01-01

    The pressure fluctuations in a centrifugal compressor with different inlet guide vanes (IGV) pre-whirl angles were investigated numerically, as well as the pre-stress model and static structural of blade. The natural frequency was evaluated by pre-stress model analysis. The results show that, the aero-dynamic pressure acting on blade surface is smaller than rotation pre-stress, which wouldn't result in large deformation of blade. The natural frequencies with rotation pre-stress are slightly higher than without rotation pre-stress. The leading mechanism of pressure fluctuations for normal conditions is the rotor-stator (IGVs) interaction, while is serious flow separations for conditions that are close to surge line. A few frequency components in spectra are close to natural frequency, which possibly result in resonant vibration if amplitude is large enough, which is dangerous for compressor working, and should be avoided

  5. Control-rod, pressure and flow-induced accident and transient analysis of a direct-cycle, supercritical-pressure, light-water-cooled fast breeder reactor

    International Nuclear Information System (INIS)

    Kitoh, Kazuaki; Koshizuka, Seiichi; Oka, Yoshiaki

    1996-01-01

    The features of the direct-cycle, supercritical-pressure, light-water-cooled fast breeder reactor (SCFBR) are high thermal efficiency and simple reactor system. The safety principle is basically the same as that of an LWR since it is a water-cooled reactor. Maintaining the core flow is the basic safety requirement of the reactor, since its coolant system is the one through type. The transient behaviors at control rod, pressure and flow-induced abnormalities are analyzed and presented in this paper. The results of flow-induced transients of SCFBR were reported at ICONE-3, though pressure change was neglected. The change of fuel temperature distribution is also considered for the analysis of the rapid reactivity-induced transients such as control rod withdrawal. Total loss of flow and pump seizure are analyzed as the accidents. Loss of load, control rod withdrawal from the normal operation, loss of feedwater heating, inadvertent start of an auxiliary feedwater pump, partial loss of coolant flow and loss of external power are analyzed as the transients. The behavior of the flow-induced transients is not so much different from the analyses assuming constant pressure. Fly wheels should be equipped with the feedwater pumps to prolong the coast-down time more than 10s and to cope with the total loss of flow accident. The coolant density coefficient of the SCFBR is less than one tenth of a BWR in which the recirculation flow is used for the power control. The over pressurization transients at the loss of load is not so severe as that of a BWR. The power reaches 120%. The minimum deterioration heat flux ratio (MDHFR) and the maximum pressure are sufficiently lower than the criteria; MDHFR above 1.0 and pressure ratio below 1.10 of 27.5 MPa, maximum pressure for operation. Among the reactivity abnormalities, the control rod withdrawal transient from the normal operation is analyzed

  6. Assessing pharmacy students' ability to accurately measure blood pressure using a blood pressure simulator arm.

    Science.gov (United States)

    Bottenberg, Michelle M; Bryant, Ginelle A; Haack, Sally L; North, Andrew M

    2013-06-12

    To compare student accuracy in measuring normal and high blood pressures using a simulator arm. In this prospective, single-blind, study involving third-year pharmacy students, simulator arms were programmed with prespecified normal and high blood pressures. Students measured preset normal and high diastolic and systolic blood pressure using a crossover design. One hundred sixteen students completed both blood pressure measurements. There was a significant difference between the accuracy of high systolic blood pressure (HSBP) measurement and normal systolic blood pressure (NSBP) measurement (mean HSBP difference 8.4 ± 10.9 mmHg vs NSBP 3.6 ± 6.4 mmHg; pdifference between the accuracy of high diastolic blood pressure (HDBP) measurement and normal diastolic blood pressure (NDBP) measurement (mean HDBP difference 6.8 ± 9.6 mmHg vs. mean NDBP difference 4.6 ± 4.5 mmHg; p=0.089). Pharmacy students may need additional instruction and experience with taking high blood pressure measurements to ensure they are able to accurately assess this important vital sign.

  7. Assessing Pharmacy Students’ Ability to Accurately Measure Blood Pressure Using a Blood Pressure Simulator Arm

    Science.gov (United States)

    Bryant, Ginelle A.; Haack, Sally L.; North, Andrew M.

    2013-01-01

    Objective. To compare student accuracy in measuring normal and high blood pressures using a simulator arm. Methods. In this prospective, single-blind, study involving third-year pharmacy students, simulator arms were programmed with prespecified normal and high blood pressures. Students measured preset normal and high diastolic and systolic blood pressure using a crossover design. Results. One hundred sixteen students completed both blood pressure measurements. There was a significant difference between the accuracy of high systolic blood pressure (HSBP) measurement and normal systolic blood pressure (NSBP) measurement (mean HSBP difference 8.4 ± 10.9 mmHg vs NSBP 3.6 ± 6.4 mmHg; pdifference between the accuracy of high diastolic blood pressure (HDBP) measurement and normal diastolic blood pressure (NDBP) measurement (mean HDBP difference 6.8 ± 9.6 mmHg vs. mean NDBP difference 4.6 ± 4.5 mmHg; p=0.089). Conclusions. Pharmacy students may need additional instruction and experience with taking high blood pressure measurements to ensure they are able to accurately assess this important vital sign. PMID:23788809

  8. FFTBM and primary pressure acceptance criterion

    International Nuclear Information System (INIS)

    Prosek, A.

    2004-01-01

    When thermalhydraulic computer codes are used for simulation in the area of nuclear engineering the question is how to conduct an objective comparison between the code calculation and measured data. To answer this the fast Fourier transform based method (FFTBM) was developed. When the FFTBM method was developed the acceptance criteria for primary pressure and total accuracy were set. In the recent study the FFTBM method was used for accuracy quantification of RD-14M large LOCA test B9401 calculations. The blind accuracy analysis indicated good total accuracy while the primary pressure criterion was not fulfilled. The objective of the study was therefore to investigate the reasons for not fulfilling the primary pressure acceptance criterion and the applicability of the criterion to experimental facilities simulating heavy water reactor. The results of the open quantitative analysis showed that sensitivity analysis for influence parameters provide sufficient information to judge in which calculation the accuracy of primary pressure is acceptable. (author)

  9. Validation of the Andon KD-5965 upper-arm blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol revision 2010.

    Science.gov (United States)

    Huang, Jinhua; Li, Zhijie; Li, Guimei; Liu, Zhaoying

    2015-10-01

    This study aimed to evaluate the accuracy of the Andon KD-5965 upper-arm blood pressure monitor according to the European Society of Hypertension International Protocol revision 2010. Systolic and diastolic blood pressures were sequentially measured in 33 adults, with 20 women using a mercury sphygmomanometer (two observers) and the Andon KD-5965 device (one supervisor). A total of 99 pairs of comparisons were obtained from 33 participants for judgments in two parts with three grading phases. The device achieved the targets in part 1 of the validation study. The number of absolute differences between the device and observers within 5, 10, and 15 mmHg was 70/99, 91/99, and 98/99, respectively, for systolic blood pressure and 81/99, 99/99, and 99/99, respectively, for diastolic blood pressure. The device also fulfilled the criteria in part 2 of the validation study. Twenty-five and 29 participants, for systolic and diastolic blood pressure, respectively, had at least two of the three device-observers differences within 5 mmHg (required≥24). Two and one participants for systolic and diastolic blood pressure, respectively, had all three device-observers comparisons greater than 5 mmHg. According to the validation results, with better performance for diastolic blood pressure than that for systolic blood pressure, the Andon automated oscillometric upper-arm blood pressure monitor KD-5965 fulfilled the requirements of the European Society of Hypertension International Protocol revision 2010, and hence can be recommended for blood pressure measurement in adults.

  10. Real-world effectiveness of valsartan on hypertension and total cardiovascular risk: review and implications of a translational research program

    Directory of Open Access Journals (Sweden)

    Abraham I

    2011-03-01

    effectiveness studies because of demographics and epidemiology. Each study used the same methodological and statistical platform. We summarize the impact of various valsartan regimens on such outcomes as blood pressure values and control, change in total cardiovascular risk, and reduction in risk by at least one category. We also review the results of statistical multilevel and logistic modeling of physician- and patient-related determinants on these outcomes, including the proportion of variance attributable to a physician class effect before patients enter the equation. In its different formulations, valsartan has major real-world benefits in lowering blood pressure and total cardiovascular risk within a 90-day period. It is essential to understand the physician- and patient-related determinants of blood pressure and total cardiovascular risk outcomes associated with valsartan treatment. Antihypertensive research should expand its historical focus on lowering blood pressure with an emphasis on lowering total cardiovascular research.Keywords: valsartan, angiotensin II receptor blocker, hypertension, total cardiovascular risk, effectiveness, pharmaco-epidemiology

  11. Contribution of energetic and heavy ions to the plasma pressure: The 27 September to 3 October 2002 storm

    Science.gov (United States)

    Kronberg, E. A.; Welling, D.; Kistler, L. M.; Mouikis, C.; Daly, P. W.; Grigorenko, E. E.; Klecker, B.; Dandouras, I.

    2017-09-01

    Magnetospheric plasma sheet ions drift toward the Earth and populate the ring current. The ring current plasma pressure distorts the terrestrial internal magnetic field at the surface, and this disturbance strongly affects the strength of a magnetic storm. The contribution of energetic ions (>40 keV) and of heavy ions to the total plasma pressure in the near-Earth plasma sheet is not always considered. In this study, we evaluate the contribution of low-energy and energetic ions of different species to the total plasma pressure for the storm observed by the Cluster mission from 27 September until 3 October 2002. We show that the contribution of energetic ions (>40 keV) and of heavy ions to the total plasma pressure is ≃76-98.6% in the ring current and ≃14-59% in the magnetotail. The main source of oxygen ions, responsible for ≃56% of the plasma pressure of the ring current, is located at distances earthward of XGSE ≃ -13.5 RE during the main phase of the storm. The contribution of the ring current particles agrees with the observed Dst index. We model the magnetic storm using the Space Weather Modeling Framework (SWMF). We assess the plasma pressure output in the ring current for two different ion outflow models in the SWMF through comparison with observations. Both models yield reasonable results. The model which produces the most heavy ions agrees best with the observations. However, the data suggest that there is still potential for refinement in the simulations.

  12. Effect of Domestic Processing Methods on Dry Matter, Total Sugar, Phenolics and Mineral Composition in Different Developmental Stages of Parkia roxburghii G. (Don. Pods

    Directory of Open Access Journals (Sweden)

    Jekendra Singh SALAM

    2013-02-01

    Full Text Available Parkia roxburghii is considered delicious in the Northeastern part of India, especially in the state of Manipur. Though it is widely used, information about the biochemical composition and its changes, after processing, is hardly available. In the present experiment, effect of processing methods on dry matter, soluble sugar, phenolics and mineral composition in different developmental stages of P. roxburghii pods were studied. Total soluble sugar (TSS, total phenols (TP, and orthodihydric phenols (ODHP were determined as per the methods of Morris (1948, Bray and Thorpe (1954 and Mahadevan and Sridhar (1986. Sodium (Na, potassium (K, sulphur (S and phosphorus (P were estimated as per the procedures of Tandon (1993. Calcium (Ca, magnesium (Mg, manganese (Mn, zinc (Zn, iron (Fe, copper (Cu and cobalt (Co were analyzed in an atomic absorption spectrophotometer. Processing methods reduced dry matter, soluble sugar and phenolics in all the stages of the pod. TP and ODHP lost up to the extent of 72.78% in tender stage due to ordinary cooking, while higher loss of ODHP recorded in immature stage of the pod due to pressure cooking. Ca, Mg, K and Zn in different stages were found to be affected significantly by different methods of cooking, while no such changes were observed in case of S, P, Fe, Mn and Cu. The level of iron amongst the micro minerals is appreciably high recording up to 51.0 mg/100 g in the immature stage of the pod. As iron, zinc and manganese are antioxidant micronutrients, their higher presence in P. roxburghii might be of some nutritional importance.

  13. Microalbuminuria Measured by three Different Methods, Blood Pressure and Cardiovascular Risk Factors in Elderly Swedish Males

    Directory of Open Access Journals (Sweden)

    Gösta Florvall

    2008-01-01

    Full Text Available Microalbuminuria is associated with hypertension and is a strong risk factor for subsequent chronic disease, both renal and coronary heart disease (CHD, Presently there are several methods available for measurement of microalbuminuria. The aim of this study was to evaluate if the three different methods gave similar information or if one of the assays were superior to the others. Blood pressure, inflammatory markers and cardiovascular mortality and morbidity were correlated with urine albumin analysed with a point-of-care testing (POCT instrument, nephelometric determination of albumin and albumin/creatinine ratio in elderly males. The study population consisted of 103 diabetic and 603 nondiabetic males (age 77 years in a cross-sectional study. We analyzed urine albumin with a HemoCue® Urine Albumin POCT instrument and a ProSpec® nephelometer and albumin/creatinine ratio. There were strong correlations between both systolic and diastolic blood pressure and all three urine albumin methods (p < 0.0001. There were also significant correlations between the different urine albumin measurements and serum amyloid A component, high-sensitivity C-reactive protein and interleukin-6. The three different urine albumin methods studied provided similar information in relation to cardiovascular disease. There was a strong correlation between systolic and diastolic blood pressure and microalbuminuria in both the whole study population and in nondiabetic males emphasizing the role of hypertension in glomerular damage. The good correlation between the studied urine albumin measurements show that all three methods can be used for monitoring urine albumin excretion.

  14. Importance of isovector effects in reproducing neutron total cross section differences in the W isotopes

    International Nuclear Information System (INIS)

    Dietrich, F.S.; Anderson, J.D.; Bauer, R.W.; Grimes, S.M.; Finlay, R.W.; Abfalterer, W.P.; Bateman, F.B.; Haight, R.C.; Morgan, G.L.; Bauge, E.; Delaroche, J.-P.; Romain, P.

    2003-01-01

    Cross section differences among the isotopes 182,184,186 W have been measured as a part of a study of total cross sections in the 5-560 MeV energy range. These difference measurements show oscillations up to 150 mb between 5 and 100 MeV. Calculations with spherical and deformed phenomenological optical potentials employing standard radial and isospin dependences show much smaller oscillations than the experimental data. In a simple Ramsauer model, this discrepancy can be traced to a cancellation between radial and isospin effects. Understanding this problem requires a more detailed model that incorporates a realistic description of the neutron and proton density distributions. This has been done with the results of Hartree-Fock-Bogoliubov calculations using the Gogny force, together with a microscopic folding model employing a modification of the Jeukenne, Lejeune, and Mahaux potential as an effective interaction. This treatment yields a satisfactory interpretation of the observed total cross section differences up to 200 MeV. The calculations have been extended above that energy with a folding model based on an empirical effective interaction

  15. Performance Analysis of Abrasive Waterjet Machining Process at Low Pressure

    Science.gov (United States)

    Murugan, M.; Gebremariam, MA; Hamedon, Z.; Azhari, A.

    2018-03-01

    Normally, a commercial waterjet cutting machine can generate water pressure up to 600 MPa. This range of pressure is used to machine a wide variety of materials. Hence, the price of waterjet cutting machine is expensive. Therefore, there is a need to develop a low cost waterjet machine in order to make the technology more accessible for the masses. Due to its low cost, such machines may only be able to generate water pressure at a much reduced rate. The present study attempts to investigate the performance of abrasive water jet machining process at low cutting pressure using self-developed low cost waterjet machine. It aims to study the feasibility of machining various materials at low pressure which later can aid in further development of an effective low cost water jet machine. A total of three different materials were machined at a low pressure of 34 MPa. The materials are mild steel, aluminium alloy 6061 and plastics Delrin®. Furthermore, a traverse rate was varied between 1 to 3 mm/min. The study on cutting performance at low pressure for different materials was conducted in terms of depth penetration, kerf taper ratio and surface roughness. It was found that all samples were able to be machined at low cutting pressure with varied qualities. Also, the depth of penetration decreases with an increase in the traverse rate. Meanwhile, the surface roughness and kerf taper ratio increase with an increase in the traverse rate. It can be concluded that a low cost waterjet machine with a much reduced rate of water pressure can be successfully used for machining certain materials with acceptable qualities.

  16. Prognostic Effect of the Nocturnal Blood Pressure Fall in Hypertensive Patients: The Ambulatory Blood Pressure Collaboration in Patients With Hypertension (ABC-H) Meta-Analysis.

    Science.gov (United States)

    Salles, Gil F; Reboldi, Gianpaolo; Fagard, Robert H; Cardoso, Claudia R L; Pierdomenico, Sante D; Verdecchia, Paolo; Eguchi, Kazuo; Kario, Kazuomi; Hoshide, Satoshi; Polonia, Jorge; de la Sierra, Alejandro; Hermida, Ramon C; Dolan, Eamon; O'Brien, Eoin; Roush, George C

    2016-04-01

    The prognostic importance of the nocturnal systolic blood pressure (SBP) fall, adjusted for average 24-hour SBP levels, is unclear. The Ambulatory Blood Pressure Collaboration in Patients With Hypertension (ABC-H) examined this issue in a meta-analysis of 17 312 hypertensives from 3 continents. Risks were computed for the systolic night-to-day ratio and for different dipping patterns (extreme, reduced, and reverse dippers) relative to normal dippers. ABC-H investigators provided multivariate adjusted hazard ratios (HRs), with and without adjustment for 24-hour SBP, for total cardiovascular events (CVEs), coronary events, strokes, cardiovascular mortality, and total mortality. Average 24-hour SBP varied from 131 to 140 mm Hg and systolic night-to-day ratio from 0.88 to 0.93. There were 1769 total CVEs, 916 coronary events, 698 strokes, 450 cardiovascular deaths, and 903 total deaths. After adjustment for 24-hour SBP, the systolic night-to-day ratio predicted all outcomes: from a 1-SD increase, summary HRs were 1.12 to 1.23. Reverse dipping also predicted all end points: HRs were 1.57 to 1.89. Reduced dippers, relative to normal dippers, had a significant 27% higher risk for total CVEs. Risks for extreme dippers were significantly influenced by antihypertensive treatment (Panalysis of hypertensive patients, the nocturnal BP fall provided substantial prognostic information, independent of 24-hour SBP levels. © 2016 American Heart Association, Inc.

  17. Experimental study and theoretical interpretation of saturation effect on ultrasonic velocity in tight sandstones under different pressure conditions

    Science.gov (United States)

    Li, Dongqing; Wei, Jianxin; Di, Bangrang; Ding, Pinbo; Huang, Shiqi; Shuai, Da

    2018-03-01

    Understanding the influence of lithology, porosity, permeability, pore structure, fluid content and fluid distribution on the elastic wave properties of porous rocks is of great significance for seismic exploration. However, unlike conventional sandstones, the petrophysical characteristics of tight sandstones are more complex and less understood. To address this problem, we measured ultrasonic velocity in partially saturated tight sandstones under different effective pressures. A new model is proposed, combining the Mavko-Jizba-Gurevich relations and the White model. The proposed model can satisfactorily simulate and explain the saturation dependence and pressure dependence of velocity in tight sandstones. Under low effective pressure, the relationship of P-wave velocity to saturation is pre-dominantly attributed to local (pore scale) fluid flow and inhomogeneous pore-fluid distribution (large scale). At higher effective pressure, local fluid flow gradually decreases, and P-wave velocity gradually shifts from uniform saturation towards patchy saturation. We also find that shear modulus is more sensitive to saturation at low effective pressures. The new model includes wetting ratio, an adjustable parameter that is closely related to the relationship between shear modulus and saturation.

  18. The effects of family income on the relationship of various anthropometric parameters with blood pressure in male population of Multan

    International Nuclear Information System (INIS)

    Khan, T.H.; Rana, S.A.; Mahmud, Z.

    2003-01-01

    A randomly selected sample of 497 human males, ageing from 18 to 90 years and representing different ethnic and socio-economic groups of Multan was taken. Income (Rs.), height (cm), weight(kg), BMI (kg m/sup -2), circumferences and blood pres one of the six different income groups i.e., 25000.Mean values plus minus SEM of income, weight, height, BMI, arm, neck, waist, hips and total circumferences, were 13881.6 plus minus 1835.6, 64.0 plus minus 0.5, 171.6 plus minus 2.9, 21.5 plus minus 0.2, 26.5 plus minus 0.1, 36.2 plus minus 0.1, 81.4 plus minus 0.5, 93.0 plus minus 0.4 and 237.2 plus minus 0.9 respectively. Systolic blood pressure (SBP), diastolic blood pressure (DBP), pulse pressure (PP) and mean arterial pressure (MAP) were 122.2 plus minus 0.5, 80.7 plus minus 0.4, 41.5 plus minus 0.5 and 94.5 plus minus 0.4 respectively. All these parameters were also recorded and analysed in different income groups. The prevalence of obesity and hypertension was found to be 3.6% and 11.4% in the total sample. The correlation and regression coefficients between different independent (income, weight, height, BMI, circumferences) and dependent (SBP, DBP, PP and MAP) parameters were calculated and it was observed that there was a strong association between different parameters (P<0.01 or P<0.05). The regression coefficients of BMI with SBP, DBP, PP and MAP were 0.744 mmHg, 0.449 mmHg, 0.296 mmHg and 0.551 per unit of BMI, respectively (P<0.001). The arm, neck, waist, hip and total circumference had regression coefficients with SBP, DBP, and MAP as, arm 0.879, 0.547, 0.667, neck 1.020, 0.660, 0.788, waist 0.244, 0.162, 0.149, hip 0.348, 0.181, 0.238 and total 0.142, 0.855, 0.105 (P<0.01) respectively. It was found that weight and BMI are more important for the prediction of blood pressure whereas all the circumferences had weak association with blood pressure. (author)

  19. Consistency of blood pressure differences between the left and right arms.

    Science.gov (United States)

    Eguchi, Kazuo; Yacoub, Mona; Jhalani, Juhee; Gerin, William; Schwartz, Joseph E; Pickering, Thomas G

    2007-02-26

    It is unclear to what extent interarm blood pressure (BP) differences are reproducible vs the result of random error. The present study was designed to resolve this issue. We enrolled 147 consecutive patients from a hypertension clinic. Three sets of 3 BP readings were recorded, first using 2 oscillometric devices simultaneously in the 2 arms (set 1); next, 3 readings were taken sequentially for each arm using a standard mercury sphygmomanometer (set 2); finally, the readings as performed for set 1 were repeated (set 3). The protocol was repeated at a second visit for 91 patients. Large interarm systolic BP differences were consistently seen in 2 patients with obstructive arterial disease. In the remaining patients, the systolic BP and the diastolic BP, respectively, were slightly higher in the right arm than in the left arm by 2 to 3 mm Hg and by 1 mm Hg for all 3 sets (Pdifference of more than 5 mm Hg were 11 (7.5%) and 4 (2.7%) across all 3 sets of readings. Among patients who repeated the test, none had a consistent interarm BP difference of more than 5 mm Hg across the 2 visits. The interarm BP difference was consistent only when obstructive arterial disease was present. Although BP in the right arm tended to be higher than in the left arm, clinically meaningful interarm differences were not reproducible in the absence of obstructive arterial disease and are attributable to random variation.

  20. Concerns of patients actively contemplating total knee replacement: differences by race and gender.

    Science.gov (United States)

    Chang, Huan J; Mehta, Priya S; Rosenberg, Aaron; Scrimshaw, Susan C

    2004-02-15

    To examine differences by race/ethnicity and gender in patients' concerns regarding total knee replacement (TKR). Focus groups of patients actively considering TKR were conducted. Discussion included patients' questions and concerns regarding TKR. The software ATLAS.ti was used to tabulate themes by race/ethnicity and gender. Concerns raised by focus group participants were compared with thematic content from patient joint replacement information materials. This comparison used patient literature from 3 high-volume academic TKR centers, the Arthritis Foundation, and the American Academy of Orthopedic Surgeons. All groups shared similar concerns. However, some issues were more prevalent among certain gender and racial groups. For instance, concerns regarding anesthesia were more important to white Americans and concerns regarding recovery were more important to women. Some of these concerns were not addressed in the available patient literature. Different gender and racial subgroups focus on different concerns when considering TKR. These differences may contribute to gender and race/ethnicity disparity seen in TKR use.

  1. Measurement of intraocular pressure with pressure phosphene tonometry in children.

    Science.gov (United States)

    Fan, Dorothy S P; Chiu, Thomas Y H; Congdon, Nathan; Chan, Jeffrey C W; Cheung, Eva Y Y; Lam, Dennis S C

    2011-01-01

    To study the accuracy and acceptability of intraocular pressure (IOP) measurement by the pressure phosphene tonometer, non-contact tonometer, and Goldmann tonometer in children. Fifty children (5 to 14 years old) participated in this prospective comparative study. IOP was measured with the pressure phosphene tonometer, non-contact tonometer, and Goldmann tonometer by three different examiners who were masked to the results. The children were also asked to grade the degree of discomfort from 0 to 5 (0 = no discomfort; 5 = most discomfort). The mean IOPs measured by the Goldmann tonometer, pressure phosphene tonometer, and non-contact tonometer were 15.9 mm Hg (standard deviation [SD]: = 5.5 mm Hg; range: 10 to 36 mm Hg), 16.0 mm Hg (SD: 2.9 mm Hg; range: 12 to 25 mm Hg), and 15.7 mm Hg (SD = 5.1 mm Hg; range: 8 to 32 mm Hg), respectively (P = .722). The mean difference between pressure phosphene tonometer and Goldmann tonometer readings was 2.9 mm Hg and that between non-contact tonometer and Goldmann tonometer readings was 2.1 mm Hg. The 95% confidence interval of the mean difference between pressure phosphene tonometer and Goldmann tonometer readings was -1.07 and 1.19, and that between non-contact tonometer and Goldmann tonometer readings was -1.07 and 0.53. The mean discomfort ratings for the pressure phosphene tonometer, non-contact tonometer, and Goldmann tonometer were 0.6, 2.0, and 2.3, respectively (P tonometer was less accurate than the non-contact tonometer compared with Goldmann tonometer, it gave a reasonably close estimate and had a high specificity of raised IOP. In addition, measurement by the pressure phosphene tonometer is most acceptable to children. The pressure phosphene tonometer can be considered as an alternative method of IOP measurement in children. Copyright 2011, SLACK Incorporated.

  2. High pressure study of the zinc phosphide semiconductor compound in two different phases

    International Nuclear Information System (INIS)

    Mokhtari, Ali

    2009-01-01

    Electronic and structural properties of the zinc phosphide semiconductor compound are calculated at hydrostatic pressure using the full-potential all-electron linearized augmented plane wave plus local orbital (FP-LAPW+lo) method in both cubic and tetragonal phases. The exchange-correlation potential is treated by the generalized gradient approximation within the scheme of Perdew, Burke and Ernzerhof, GGA96 (1996 Phys. Rev. Lett. 77 3865). Also, the Engel and Vosko GGA formalism, EV-GGA (Engel and Vosko 1993 Phys. Rev. B 47 13164), is used to improve the band-gap results. Internal parameters are optimized by relaxing the atomic positions in the force directions using the Hellman-Feynman approach. The lattice constants, internal parameters, bulk modulus, cohesive energy and band structures have been calculated and compared to the available experimental and theoretical results. The structural calculations predict that the stable phase is tetragonal. The effects of hydrostatic pressure on the behavior of band parameters such as band-gap, valence bandwidths and internal gaps (the energy gap between different parts of the valence bands) are studied using both GGA96 and EV-GGA.

  3. High pressure study of the zinc phosphide semiconductor compound in two different phases

    Energy Technology Data Exchange (ETDEWEB)

    Mokhtari, Ali [Simulation Laboratory, Department of Physics, Faculty of Science, Shahrekord University, PB 115, Shahrekord (Iran, Islamic Republic of)], E-mail: mokhtari@sci.sku.ac.ir

    2009-07-08

    Electronic and structural properties of the zinc phosphide semiconductor compound are calculated at hydrostatic pressure using the full-potential all-electron linearized augmented plane wave plus local orbital (FP-LAPW+lo) method in both cubic and tetragonal phases. The exchange-correlation potential is treated by the generalized gradient approximation within the scheme of Perdew, Burke and Ernzerhof, GGA96 (1996 Phys. Rev. Lett. 77 3865). Also, the Engel and Vosko GGA formalism, EV-GGA (Engel and Vosko 1993 Phys. Rev. B 47 13164), is used to improve the band-gap results. Internal parameters are optimized by relaxing the atomic positions in the force directions using the Hellman-Feynman approach. The lattice constants, internal parameters, bulk modulus, cohesive energy and band structures have been calculated and compared to the available experimental and theoretical results. The structural calculations predict that the stable phase is tetragonal. The effects of hydrostatic pressure on the behavior of band parameters such as band-gap, valence bandwidths and internal gaps (the energy gap between different parts of the valence bands) are studied using both GGA96 and EV-GGA.

  4. Effect of air pollution on the total bacteria and pathogenic bacteria in different sizes of particulate matter.

    Science.gov (United States)

    Liu, Huan; Zhang, Xu; Zhang, Hao; Yao, Xiangwu; Zhou, Meng; Wang, Jiaqi; He, Zhanfei; Zhang, Huihui; Lou, Liping; Mao, Weihua; Zheng, Ping; Hu, Baolan

    2018-02-01

    In recent years, air pollution events have occurred frequently in China during the winter. Most studies have focused on the physical and chemical composition of polluted air. Some studies have examined the bacterial bioaerosols both indoors and outdoors. But few studies have focused on the relationship between air pollution and bacteria, especially pathogenic bacteria. Airborne PM samples with different diameters and different air quality index values were collected in Hangzhou, China from December 2014 to January 2015. High-throughput sequencing of 16S rRNA was used to categorize the airborne bacteria. Based on the NCBI database, the "Human Pathogen Database" was established, which is related to human health. Among all the PM samples, the diversity and concentration of total bacteria were lowest in the moderately or heavily polluted air. However, in the PM2.5 and PM10 samples, the relative abundances of pathogenic bacteria were highest in the heavily and moderately polluted air respectively. Considering the PM samples with different particle sizes, the diversities of total bacteria and the proportion of pathogenic bacteria in the PM10 samples were different from those in the PM2.5 and TSP samples. The composition of PM samples with different sizes range may be responsible for the variances. The relative humidity, carbon monoxide and ozone concentrations were the main factors, which affected the diversity of total bacteria and the proportion of pathogenic bacteria. Among the different environmental samples, the compositions of the total bacteria were very similar in all the airborne PM samples, but different from those in the water, surface soil, and ground dust samples. Which may be attributed to that the long-distance transport of the airflow may influence the composition of the airborne bacteria. This study of the pathogenic bacteria in airborne PM samples can provide a reference for environmental and public health researchers. Copyright © 2017 Elsevier Ltd

  5. GEO-MIX-SELF calculations of the elastic properties of a textured graphite sample at different hydrostatic pressures

    International Nuclear Information System (INIS)

    Matthies, Siegfried

    2012-01-01

    The recently developed GEO-MIX-SELF approximation (GMS) is applied to interpret the pressure dependence of the longitudinal ultrasonic wave velocities in a polycrystalline graphite sample that has already been investigated in a wide range of experimental contexts. Graphite single crystals have extremely anisotropic elastic properties, making this sample a challenging test to demonstrate the potential of the GMS method. GMS combines elements of well known self-consistent algorithms and of the geometric mean approximation. It is able to consider mixtures of different polycrystalline phases, each with its own nonspherical grain shape and preferred orientation (texture). Pores and 'cracks', typical for bulk graphite, are modeled as phases with 'empty' grains. The pressure dependence (up to 150 MPa) of the experimental wave velocities can be well explained using the known texture of the sample by fitting the shape parameters and volume fractions of the graphite grains, cracks and spherical pores. The pressure dependence of these parameters describes a reasonable scenario for the closing of the cracks and pores with increasing pressure. (orig.)

  6. Preliminary Experimental Study on Pressure Loss Coefficients of Exhaust Manifold Junction

    Directory of Open Access Journals (Sweden)

    Xiao-lu Lu

    2014-01-01

    Full Text Available The flow characteristic of exhaust system has an important impact on inlet boundary of the turbine. In this paper, high speed flow in a diesel exhaust manifold junction was tested and simulated. The pressure loss coefficient of the junction flow was analyzed. The steady experimental results indicated that both of static pressure loss coefficients L13 and L23 first increased and then decreased with the increase of mass flow ratio of lateral branch and public manifold. The total pressure loss coefficient K13 always increased with the increase of mass flow ratio of junctions 1 and 3. The total pressure loss coefficient K23 first increased and then decreased with the increase of mass flow ratio of junctions 2 and 3. These pressure loss coefficients of the exhaust pipe junctions can be used in exhaust flow and turbine inlet boundary conditions analysis. In addition, simulating calculation was conducted to analyze the effect of branch angle on total pressure loss coefficient. According to the calculation results, total pressure loss coefficient was almost the same at low mass flow rate of branch manifold 1 but increased with lateral branch angle at high mass flow rate of branch manifold 1.

  7. Ultrasonic sludge pretreatment under pressure.

    Science.gov (United States)

    Le, Ngoc Tuan; Julcour-Lebigue, Carine; Delmas, Henri

    2013-09-01

    The objective of this work was to optimize the ultrasound (US) pretreatment of sludge. Three types of sewage sludge were examined: mixed, secondary and secondary after partial methanisation ("digested" sludge). Thereby, several main process parameters were varied separately or simultaneously: stirrer speed, total solid content of sludge (TS), thermal operating conditions (adiabatic vs. isothermal), ultrasonic power input (PUS), specific energy input (ES), and for the first time external pressure. This parametric study was mainly performed for the mixed sludge. Five different TS concentrations of sludge (12-36 g/L) were tested for different values of ES (7000-75,000 kJ/kgTS) and 28 g/L was found as the optimum value according to the solubilized chemical oxygen demand in the liquid phase (SCOD). PUS of 75-150 W was investigated under controlled temperature and the "high power input - short duration" procedure was the most effective at a given ES. The temperature increase in adiabatic US application significantly improved SCOD compared to isothermal conditions. With PUS of 150 W, the effect of external pressure was investigated in the range of 1-16 bar under isothermal and adiabatic conditions for two types of sludge: an optimum pressure of about 2 bar was found regardless of temperature conditions and ES values. Under isothermal conditions, the resulting improvement of sludge disintegration efficacy as compared to atmospheric pressure was by 22-67% and 26-37% for mixed and secondary sludge, respectively. Besides, mean particle diameter (D[4,3]) of the three sludge types decreased respectively from 408, 117, and 110 μm to about 94-97, 37-42, and 36-40 μm regardless of sonication conditions, and the size reduction process was much faster than COD extraction. Copyright © 2013 Elsevier B.V. All rights reserved.

  8. Titration effectiveness of two autoadjustable continuous positive airway pressure devices driven by different algorithms in patients with obstructive sleep apnoea.

    Science.gov (United States)

    Damiani, Mario Francesco; Quaranta, Vitaliano Nicola; Tedeschi, Ersilia; Drigo, Riccardo; Ranieri, Teresa; Carratù, Pierluigi; Resta, Onofrio

    2013-08-01

    Nocturnal application of continuous positive airway pressure (CPAP) is the standard treatment for patients with obstructive sleep apnoea (OSA). Determination of the therapeutic pressure (CPAP titration) is usually performed by a technician in the sleep laboratory during attended polysomnography. One possible alternative to manual titration is automated titration. Indeed, during the last 15 years, devices have been developed that deliver autoadjustable CPAP (A-CPAP). The aim of the present study was to compare the titration effectiveness of two A-CPAP devices using different flow-based algorithms in patients with OSA. This is a randomized study; 79 subjects underwent two consecutive unattended home A-CPAP titration nights with two different devices (Autoset Resmed; Remstar Auto Respironics); during the third and the fourth night, patients underwent portable monitoring in the sleep laboratory during fixed CPAP at the A-CPAP recommended pressure. Bland Altman plots showed good agreement between the recommended median and maximal pressure levels obtained with the two devices. A significant improvement was observed in all the sleep parameters by both A-CPAP machines to a similar degree. It was observed that the two A-CPAP devices using different algorithms are equally effective in initial titration of CPAP. © 2013 The Authors. Respirology © 2013 Asian Pacific Society of Respirology.

  9. Agreement of high definition oscillometry with direct arterial blood pressure measurement at different blood pressure ranges in horses under general anaesthesia.

    Science.gov (United States)

    Tünsmeyer, Julia; Hopster, Klaus; Feige, Karsten; Kästner, Sabine Br

    2015-05-01

    To determine the agreement of high definition oscillometry (HDO) with direct arterial blood pressure measurements in normotensive, hypotensive and hypertensive horses during general anaesthesia. Experimental study. Seven healthy warmblood horses, aged 3-11 years, weighing 470-565 kg. Measurements from a HDO device with the cuff placed around the base of the tail were compared with pressures measured invasively from the facial artery. High blood pressures were induced by intravenous (IV) administration of dobutamine (5 μg kg(-1) minute(-1)) over ten minutes followed by norepinephrine (0.1 mg kg(-1) IV) and low pressures by increasing the inspired fraction of isoflurane and administration of nitroglycerine (0.05 mg kg(-1) IV). For analysis three pressure levels were determined: high (MAP>110 mmHg), normal (60 mmHgstandard deviation for SAP, MAP and DAP were 0.1 ± 19.4 mmHg, 0.5 ± 14.0, 4.7 ± 15.6, respectively. At high pressure levels bias and SD were 26.1 ± 37.3 (SAP), 4.2 ± 19.4 (MAP), 1.5 ± 16.8 (DAP) and at low pressures -20.0 ± 20.9 (SAP), -11.4 ± 19.6 (MAP), -4.7 ± 20.1 (DAP), with HDO measurements at a MAP <50 mmHg often failing. Good agreement with invasive arterial blood pressures was obtained with HDO at normotensive levels in horses. At high and low pressure ranges HDO was unreliable. Therefore, if haemodynamic instability is expected, invasive measurement remains preferable. © 2014 Association of Veterinary Anaesthetists and the American College of Veterinary Anesthesia and Analgesia.

  10. Influence of temperature and pressure on the lethality of ultrasound

    International Nuclear Information System (INIS)

    Raso, J.; Pagan, R.; Condon, S.; Sala, F.J.

    1998-01-01

    A specially designed resistometer was constructed, and the lethal effect on Yersinia enterocolitica of ultrasonic waves (UW) at different static pressures (manosonication [MS]) and of combined heat-UW under pressure treatments (manothermosonication [MTS]) was investigated. During MS treatments at 30 degrees C and 200 kPa, the increase in the amplitude of UW of 20 kHz from 21 to 150 micrometers exponentially decreased decimal reduction time values (D(MS)) from 4 to 0.37 min. When pressure was increased from 0 to 600 kPa at a constant amplitude (150 micrometers) and temperature (30 degrees C), D(MS) values decreased from 1.52 to 0.20 min. The magnitude of this decrease in D(MS) declined progressively as pressure was increased. The influence of pressure on D(MS) values was greater with increased amplitude of UW. Pressure alone of as much as 600 kPa did not influence the heat resistance of Y. enterocolitica (D60 = 0.094; zeta = 5.65). At temperatures of as much as 58 degrees C, the lethality of UW under pressure was greater than that of heat treatment alone at the same temperature. At higher temperatures, this difference disappeared. Heat and UW under pressure seemed to act independently. The lethality of MTS treatments appeared to result from the added effects of UW under pressure and the lethal effect of heat. The individual contributions of heat and of UW under pressure to the total lethal effect of MTS depended on temperature. The inactivating effect of UW was not due to titanium particles eroded from the sonication horn. The addition to the MS media of cysteamine did not increase the resistance of Y. enterocolitica to MS treatment. MS treatment caused cell disruption

  11. Attachment of MEM piezoresistive silicon pressure sensor dies using different adhesives

    Directory of Open Access Journals (Sweden)

    Jović Vesna B.

    2011-01-01

    Full Text Available This paper gives comparison and discussion of adhesives used for attachment of silicon piezoresistive pressure sensor dies. Special attention is paid on low pressure sensor dies because of their extreme sensitivity on stresses, which can arise from packaging procedure and applied materials. Commercially available adhesives “Scotch Weld 2214 Hi-Temp” from “3M Co.” and “DM2700P/H848” from “DIEMAT”, USA, were compared. First of them is aluminum filled epoxy adhesive and second is low melting temperature (LMT glass paste. Comparing test results for low pressure sensor chips we found that LMT glass (glass frit is better adhesive for this application. Applying LMT glass paste minimizes internal stresses caused by disagreement of coefficients of thermal expansions between sensor die and housing material. Also, it minimizes stresses introduced during applying external loads in the process of pressure measuring. Regarding the measurements, for the sensors installed with filled epoxy paste, resistor for compensation of temperature offset change had negative values in all cases, which means that linear temperature compensation, of sensors installed this way, would be impossible. In the sensors installed with LMT glass paste, all results, without exception, were in their common limits (values, which give the possibility of passive temperature compensation. Furthermore, LMT glass attachment can broaden temperature operating range of MEM silicon pressure sensors towards higher values, up to 120 ºC.

  12. Development of an electronic manometer for intrapleural pressure monitoring.

    Science.gov (United States)

    Krenke, Rafał; Guć, Maciej; Grabczak, Elżbieta Magdalena; Michnikowski, Marcin; Pałko, Krzysztof Jakub; Chazan, Ryszarda; Gólczewski, Tomasz

    2011-01-01

    Measurement of intrapleural pressure is useful during various pleural procedures. However, a pleural manometer is rarely available. The aim of this study was to (1) construct an electronic pleural manometer, (2) assess the accuracy of the measurements done with the new device, (3) calculate the costs of the manometer construction and (4) perform an initial evaluation of the device in a clinical setting. Only widely accessible elements were used to construct the device. A vascular pressure transducer was used to transform pressure into an electronic signal. Reliability of the measurements was evaluated in a laboratory setting in a prospective, single-blind manner by comparing the results with those measured by a water manometer. Functionality of the device was assessed during therapeutic thoracentesis. The cost of the new pleural manometer was calculated. We built a small, portable device which can precisely measure intrapleural pressure. The measurement results showed very high agreement with those registered with a water manometer (r = 0.999; p electronic manometer during therapeutic thoracentesis showed it was easy to use. The total time needed for 6 measurements after withdrawal of different volumes of pleural fluid in 1 patient did not exceed 6 min. The total cost of the device was calculated to be electronic pleural manometer at modest costs. The device is easy to use and enables data display and storage in the personal computer. Copyright © 2011 S. Karger AG, Basel.

  13. Geographical differences in the relationship between total dissolved ...

    African Journals Online (AJOL)

    The practical application of these findings is that users of EC meters should not simply apply a blanket conversion factor, but need to select an applicable factor for the river system in which they are measuring. Keywords: conversion factors, electrical conductivity, field instruments, rivers, total dissolved solids, water quality ...

  14. A finite-difference time-domain simulation of high power microwave generated plasma at atmospheric pressures

    International Nuclear Information System (INIS)

    Ford, Patrick J.; Beeson, Sterling R.; Krompholz, Hermann G.; Neuber, Andreas A.

    2012-01-01

    A finite-difference algorithm was developed to calculate several RF breakdown parameters, for example, the formative delay time that is observed between the initial application of a RF field to a dielectric surface and the formation of field-induced plasma interrupting the RF power flow. The analysis is focused on the surface being exposed to a background gas pressure above 50 Torr. The finite-difference algorithm provides numerical solutions to partial differential equations with high resolution in the time domain, making it suitable for simulating the time evolving interaction of microwaves with plasma; in lieu of direct particle tracking, a macroscopic electron density is used to model growth and transport. This approach is presented as an alternative to particle-in-cell methods due to its low complexity and runtime leading to more efficient analysis for a simulation of a microsecond scale pulse. The effect and development of the plasma is modeled in the simulation using scaling laws for ionization rates, momentum transfer collision rates, and diffusion coefficients, as a function of electric field, gas type and pressure. The incorporation of plasma material into the simulation involves using the Z-transform to derive a time-domain algorithm from the complex frequency-dependent permittivity of plasma. Therefore, the effect of the developing plasma on the instantaneous microwave field is calculated. Simulation results are compared with power measurements using an apparatus designed to facilitate surface flashover across a polycarbonate boundary in a controlled N 2 , air, or argon environment at pressures exceeding 50 Torr.

  15. Association between general and abdominal obesity with high blood pressure: difference between genders.

    Science.gov (United States)

    Silva, Alison O; Silva, Micaelly V; Pereira, Lisley K N; Feitosa, Wallacy M N; Ritti-Dias, Raphael M; Diniz, Paula R B; Oliveira, Luciano M F T

    2016-01-01

    To assess the association between general and abdominal obesity with high blood pressure in adolescents of both genders from the public school system. This was an epidemiological, descriptive, exploratory study, with a quantitative approach and local scope whose sample consisted of 481 high school students (aged 14-19), selected by using a random cluster sampling strategy. Blood pressure was measured through the use of automated monitor and was considered high when the pressure values were at or above the 95th percentile. The analyses were performed using the chi-squared test and binary logistic regression. The prevalence of high blood pressure was 6.4%, and it was higher among boys (9.0% vs. 4.7%, phigh blood pressure was associated with general (OR=6.4; phigh blood pressure only in boys, regardless of age. Copyright © 2015 Sociedade Brasileira de Pediatria. Published by Elsevier Editora Ltda. All rights reserved.

  16. Heat transfer and pressure measurements for the SSME fuel turbine

    Science.gov (United States)

    Dunn, Michael G.; Kim, Jungho

    1991-01-01

    A measurement program is underway using the Rocketdyne two-stage Space Shuttle Main Engine (SSME) fuel turbine. The measurements use a very large shock tunnel to produce a short-duration source of heated and pressurized gas which is subsequently passed through the turbine. Within this environment, the turbine is operated at the design values of flow function, stage pressure ratio, stage temperature ratio, and corrected speed. The first stage vane row and the first stage blade row are instrumented in both the spanwise and chordwise directions with pressure transducers and heat flux gages. The specific measurements to be taken include time averaged surface pressure and heat flux distributions on the vane and blade, flow passage static pressure, flow passage total pressure and total temperature distributions, and phase resolved surface pressure and heat flux on the blade.

  17. [Effects of acupuncture on circadian rhythm of blood pressure in patients with essential hypertension].

    Science.gov (United States)

    Lei, Yun; Jin, Jiu; Ban, Haipeng; Du, Yuzheng

    2017-11-12

    To observe the effects of acupuncture combined with medication on circadian rhythm of blood pressure in patients with essential hypertension. Sixty-four patients of essential hypertension were randomly divided into an observation group and a control group, 32 cases in each group. All the patients maintained original treatment (taking antihypertensive medication); the patients in the observation group were treated with acupuncture method of " Huoxue Sanfeng , Shugan Jianpi ", once a day, five times per week, for totally 6 weeks (30 times). The circadian rhythm of blood pressure and related dynamic parameters were observed before and after treatment in the two groups. (1) The differences of daytime average systolic blood pressure (dASBP), daytime average diastolic blood pressure (dADBP), nighttime average systolic blood pressure (nASBP) and circadian rhythm of systolic blood pressure before and after treatment were significant in the observation group (all P circadian rhythm of blood pressure and related dynamic parameters before and after treatment were insignificant in the control group (all P >0.05). The nASBP and circadian rhythm of systolic blood pressure in the observation group were significantly different from those in the control group (all P circadian rhythm of blood pressure in the observation group was higher than that in the control group ( P circadian rhythm of blood pressure and related dynamic parameters in patients with essential hypertension.

  18. Total factor productivity (TFP) growth agriculture in pakistan: trends in different time horizons

    International Nuclear Information System (INIS)

    Ali, A.; Mushtaq, K.; Ashfaq, M.

    2008-01-01

    The present study estimated total factor productivity (TFP) growth of agriculture sector of Pakistan for the period 1971-2006 by employing Tornqvist-Theil (T-T) index number methodology. Most of the conventional inputs were used in constructing the input index. The output index includes major crops, minor crops, important fruits and vegetables and four categories of livestock products. The study estimated TFP growth rates for different decades. The results showed that TFP growth rate was lowest during the decade of 70s (0.96 percent) and highest during the last six years of the study period (2.86 percent). The decade of 80s and 90s registered TFP growth rate of 2.24 percent and 2.46 percent, respectively. The results also explained that TFP growth contributed about 33 percent to total agricultural output growth during the decade of 70s and this contribution increased up to 83 percent during the last six years of the study period. The contribution of TFP growth to total agricultural output growth was 53 and 81 percent during the decades of 80s and 90s, respectively. The study observed that macro level government policies, institutional factors and weather conditions are the major key factors that influenced TFP growth. (author)

  19. Modified pressure loss model for T-junctions of engine exhaust manifold

    Science.gov (United States)

    Wang, Wenhui; Lu, Xiaolu; Cui, Yi; Deng, Kangyao

    2014-11-01

    The T-junction model of engine exhaust manifolds significantly influences the simulation precision of the pressure wave and mass flow rate in the intake and exhaust manifolds of diesel engines. Current studies have focused on constant pressure models, constant static pressure models and pressure loss models. However, low model precision is a common disadvantage when simulating engine exhaust manifolds, particularly for turbocharged systems. To study the performance of junction flow, a cold wind tunnel experiment with high velocities at the junction of a diesel exhaust manifold is performed, and the variation in the pressure loss in the T-junction under different flow conditions is obtained. Despite the trend of the calculated total pressure loss coefficient, which is obtained by using the original pressure loss model and is the same as that obtained from the experimental results, large differences exist between the calculated and experimental values. Furthermore, the deviation becomes larger as the flow velocity increases. By improving the Vazsonyi formula considering the flow velocity and introducing the distribution function, a modified pressure loss model is established, which is suitable for a higher velocity range. Then, the new model is adopted to solve one-dimensional, unsteady flow in a D6114 turbocharged diesel engine. The calculated values are compared with the measured data, and the result shows that the simulation accuracy of the pressure wave before the turbine is improved by 4.3% with the modified pressure loss model because gas compressibility is considered when the flow velocities are high. The research results provide valuable information for further junction flow research, particularly the correction of the boundary condition in one-dimensional simulation models.

  20. The role of hyperglycemia, insulin resistance, and blood pressure in diabetes-associated differences in cognitive performance - The Maastricht study

    NARCIS (Netherlands)

    Geijselaers, Stefan L C; Sep, Simone J S; Claessens, Danny; Schram, Miranda T; Van Boxtel, Martin P J; Henry, Ronald M. A.; Verhey, Frans R J; Kroon, Abraham A; Dagnelie, Pieter C.; Schalkwijk, Casper G.; van der Kallen, Carla J H; Biessels, Geert Jan; Stehouwer, Coen D. A.

    2017-01-01

    OBJECTIVE To study to what extent differences in cognitive performance between individuals with different glucose metabolism status are potentially attributable to hyperglycemia, insulin resistance, and blood pressure-related variables. RESEARCH DESIGN AND METHODS We used cross-sectional data from

  1. Combined effect of blood pressure and total cholesterol levels on long-term risks of subtypes of cardiovascular death: Evidence for Cardiovascular Prevention from Observational Cohorts in Japan.

    Science.gov (United States)

    Satoh, Michihiro; Ohkubo, Takayoshi; Asayama, Kei; Murakami, Yoshitaka; Sakurai, Masaru; Nakagawa, Hideaki; Iso, Hiroyasu; Okayama, Akira; Miura, Katsuyuki; Imai, Yutaka; Ueshima, Hirotsugu; Okamura, Tomonori

    2015-03-01

    No large-scale, longitudinal studies have examined the combined effects of blood pressure (BP) and total cholesterol levels on long-term risks for subtypes of cardiovascular death in an Asian population. To investigate these relationships, a meta-analysis of individual participant data, which included 73 916 Japanese subjects (age, 57.7 years; men, 41.1%) from 11 cohorts, was conducted. During a mean follow-up of 15.0 years, deaths from coronary heart disease, ischemic stroke, and intraparenchymal hemorrhage occurred in 770, 724, and 345 cases, respectively. Cohort-stratified Cox proportional hazard models were used. After stratifying the participants by 4 systolic BP ×4 total cholesterol categories, the group with systolic BP ≥160 mm Hg with total cholesterol ≥5.7 mmol/L had the greatest risk for coronary heart disease death (adjusted hazard ratio, 4.39; Pdeath, and total cholesterol was inversely associated with intraparenchymal hemorrhage, but no significant interactions between BP and total cholesterol were observed for stroke. High BP and high total cholesterol can synergistically increase the risk for coronary heart disease death but not for stroke in the Asian population. © 2015 American Heart Association, Inc.

  2. Correlation of Noninvasive Blood Pressure and Invasive Intra-arterial Blood Pressure in Patients Treated with Vasoactive Medications in a Neurocritical Care Unit.

    Science.gov (United States)

    Saherwala, Ali A; Stutzman, Sonja E; Osman, Mohamed; Kalia, Junaid; Figueroa, Stephen A; Olson, DaiWai M; Aiyagari, Venkatesh

    2018-03-22

    The correlation between noninvasive (oscillometric) blood pressure (NBP) and intra-arterial blood pressure (IAP) in critically ill patients receiving vasoactive medications in a Neurocritical Care Unit has not been systematically studied. The purpose of this study is to examine the relationship between simultaneously measured NBP and IAP recordings in these patients. Prospective observational study of patients (N = 70) admitted to a neurocritical care unit receiving continuous vasopressor or antihypertensive infusions. Paired NBP/IAP observations along with covariate and demographic data were abstracted via chart audit. Analysis was performed using SAS v9.4. A total of 2177 paired NBP/IAP observations from 70 subjects (49% male, 63% white, mean age 59 years) receiving vasopressors (n = 21) or antihypertensive agents (n = 49) were collected. Paired t test analysis showed significant differences between NBP versus IAP readings: ([systolic blood pressure (SBP): mean = 136 vs. 140 mmHg; p blood pressure (DBP): mean = 70 vs. 68 mmHg, p blood pressure (MAP): mean = 86 vs. 90 mmHg, p blood pressures. Pearson correlation coefficients show strong positive correlations for paired MAP (r = 0.82), SBP (r = 0.84), and DBP (r = 0.73) recordings. An absolute NBP-IAP SBP difference of > 20 mmHg was seen in ~ 20% of observations of nicardipine, ~ 25% of observations of norepinephrine, and ~ 35% of observations of phenylephrine. For MAP, the corresponding numbers were ~ 10, 15, and 25% for nicardipine, norepinephrine, and phenylephrine, respectively. Despite overall strong positive correlations between paired NBP and IAP readings of MAP and SBP, clinically relevant differences in blood pressure are frequent. When treating with vasoactive infusions targeted to a specific BP goal, it is important to keep in mind that NBP and IAP values are not interchangeable.

  3. The elastic constants and anisotropy of superconducting MgCNi3 and CdCNi3 under different pressure

    KAUST Repository

    Feng, Huifang

    2013-11-23

    The second-order elastic constants (SOECs) and third-order elastic constants (TOECs) of MgCNi3 and CdCNi3 are presented by using first-principles methods combined with homogeneous deformation theory. The Voigt-Reuss-Hill (VRH) approximation are used to calculate the bulk modulus B, shear modulus G, averaged Young\\'s modulus E and Poisson\\'s ratio ν for polycrystals and these effective modulus are consistent with the experiments. The SOECs under different pressure of MgCNi3 and CdCNi3 are also obtained based on the TOECs. Furthermore, the Zener anisotropy factor, Chung-Buessem anisotropy index, and the universal anisotropy index are used to describe the anisotropy of MgCNi3 and CdCNi3. The anisotropy of Young\\'s modulus of single-crystal under different pressure is also presented. © 2013 Springer Science+Business Media New York.

  4. Effects of pressure and temperature on thermal contact resistance between different materials

    Directory of Open Access Journals (Sweden)

    Zhao Zhe

    2015-01-01

    Full Text Available To explore whether pressure and temperature can affect thermal contact resistance, we have proposed a new experimental approach for measurement of the thermal contact resistance. Taking the thermal contact resistance between phenolic resin and carbon-carbon composites, cuprum, and aluminum as the examples, the influence of the thermal contact resistance between specimens under pressure is tested by experiment. Two groups of experiments are performed and then an analysis on influencing factors of the thermal contact resistance is presented in this paper. The experimental results reveal that the thermal contact resistance depends not only on the thermal conductivity coefficient of materials, but on the interfacial temperature and pressure. Furthermore, the thermal contact resistance between cuprum and aluminum is more sensitive to pressure and temperature than that between phenolic resin and carbon-carbon composites.

  5. Spinal Cord Injury and Pressure Ulcer Prevention: Using Functional Activity in Pressure Relief

    Directory of Open Access Journals (Sweden)

    May Stinson

    2013-01-01

    Full Text Available Background. People with spinal cord injury (SCI are at increased risk of pressure ulcers due to prolonged periods of sitting. Concordance with pressure relieving movements is poor amongst this population, and one potential alternative to improve this would be to integrate pressure relieving movements into everyday functional activities. Objectives. To investigate both the current pressure relieving behaviours of SCI individuals during computer use and the application of an ergonomically adapted computer-based activity to reduce interface pressure. Design. Observational and repeated measures design. Setting. Regional Spinal Cord Injury Unit. Participants. Fourteen subjects diagnosed with SCI (12 male, 2 female. Intervention.Comparing normal sitting to seated movements and induced forward reaching positions. Main Outcome Measures. Interface pressure measurements: dispersion index (DI, peak pressure index (PPI, and total contact area (CA. The angle of trunk tilt was also measured. Results. The majority of movements yielded less than 25% reduction in interface pressure compared to normal sitting. Reaching forward by 150% of arm length during an adapted computer activity significantly reduced DI (P<0.05, angle of trunk tilt (p<0.05, and PPI for both ischial tuberosity regions (P<0.001 compared to normal sitting. Conclusion. Reaching forward significantly redistributed pressure at the seating interface, as evidenced by the change in interface pressures compared to upright sitting.

  6. Proposed frustrated-total-reflection acoustic sensing method

    International Nuclear Information System (INIS)

    Hull, J.R.

    1981-01-01

    Modulation of electromagnetic energy transmission through a frustrated-total-reflection device by pressure-induced changes in the index of refraction is proposed for use as an acoustic detector. Maximum sensitivity occurs for angles of incidence near the critical angle. The minimum detectable pressure in air is limited by Brownian noise. Acoustic propagation losses and diffraction of the optical beam by the acoustic signal limit the minimum acoustic wavelength to lengths of the order of the spatial extent of the optical beam. The response time of the method is fast enough to follow individual acoustic waves

  7. Time-resolved investigation of an asymmetric bipolar pulsed magnetron deposition discharge: Influence of pressure

    NARCIS (Netherlands)

    Dunger, Th.; Welzel, Th.; Welzel, S.; Richter, F.

    2005-01-01

    A bipolar pulsed magnetron deposition discharge has been studied with pulse frequencies of 100 and 150 kHz, respectively. The discharge was operated in an argon/oxygen mixture at different total pressures with a circular magnesium target as cathode. Time-resolved Langmuir double probe measurements

  8. The National Expert Standard Pressure Ulcer Prevention in Nursing and pressure ulcer prevalence in German health care facilities: a multilevel analysis.

    Science.gov (United States)

    Wilborn, Doris; Grittner, Ulrike; Dassen, Theo; Kottner, Jan

    2010-12-01

    The objective of this study was to describe the relationship between the German National Expert Standard Pressure Ulcer Prevention and the pressure ulcer prevalence in German nursing homes and hospitals. The patient outcome pressure ulcer does not only depend on individual characteristics of patients, but also on institutional factors. In Germany, National Expert Standards are evidence-based instruments that build the basis of continuing improvement in health care quality. It is expected that after having implemented the National Expert Standard Pressure Ulcer Prevention, the number of pressure ulcers should decrease in health care institutions. The analysed data were obtained from two cross-sectional studies from 2004-2005. A multilevel analysis was performed to show the impact of the National Expert Standard Pressure Ulcer Prevention on pressure ulcer prevalence. A total of 41.5% of hospitals and 38.8% of the nursing homes claimed to use the National Expert Standard in the process of developing their local protocols. The overall pressure ulcer prevalence grade 2-4 was 4.7%. Adjusted for hospital departments, survey year and individual characteristics, there was no significant difference in the prevalence of pressure ulcers between institutions that refer to the National Expert Standard or those referring to other sources in developing their local protocols (OR=1.14, 95% CI=0.90-1.44). There was no empirical evidence demonstrating that local protocols of pressure ulcer prevention based on the National Expert Standard were superior to local protocols which refer other sources of knowledge with regard to the pressure ulcer prevalence. The use of the National Expert Standard Pressure Ulcer Prevention can neither be recommended nor be refused. The recent definition of implementation of Expert Standards should be mandatory for all health care institutions which introduce Expert Standards. © 2010 Blackwell Publishing Ltd.

  9. Interarm systolic blood pressure difference is associated with myocardial injury after noncardiac surgery.

    Science.gov (United States)

    Belen, Erdal; Ozal, Ender; Bayyigit, Akif; Gunaydın, Senay; Helvacı, Aysen

    Myocardial injury after non-cardiac surgery (MINS) is closely related to increased cardiovascular mortality. To evaluate the relationship between MINS and interarm systolic blood pressure difference (IASBPD), which has previously been shown to correlate with the frequency of cardiovascular events and arterial arteriosclerotic processes. This observational, single-centre cohort study included 240 consecutive noncardiac surgery patients aged ≥ 45 years. Simultaneous blood pressure recordings were taken preoperatively and IASBPD was calculated. Patients' electrocardiography recordings and high sensitivity cardiac troponin T (hscTnT) levels were obtained for a period of three days postoperatively. Postoperatively, 27 (11.3%) patients were found to have MINS when hscTnT ≥ 14 ng/L was taken as a cut-off value. IASBPD > 10 mm Hg was found in 44 (18.3%) patients. When IASBPD was accepted to be a continuous variable, there was a higher IASBPD value in the MINS group (9.4 ± 5.0 vs. 4.5 ± 3.8, p 10 mm Hg and those not, exaggerate IASBPD was found to be more frequent in patients developing MINS (16 [59.3%] vs. 28 [13.1%], respectively, p 10 mm Hg to be independently associated with the development of MINS (OR: 30.82; CI: 9.14-103.98; p AUC = 0.79; 95% CI 0.71-0.87). Increased IASBPD is closely related to development of MINS. The preoperative measurement of blood pressure from both arms may be an important and easy to use clinical tool in determining cardiovascular risk.

  10. Measurement of ion beam angular distribution at different helium gas pressures in a plasma focus device by large-area polycarbonate detectors

    Energy Technology Data Exchange (ETDEWEB)

    Sohrabi, M.; Habibi, M., E-mail: mortezahabibi@gmail.com; Ramezani, V. [Amirkabir University of Technology, Energy Engineering and Physics Department (Iran, Islamic Republic of)

    2017-02-15

    The paper presents an experimental study and analysis of full helium ion density angular distributions in a 4-kJ plasma focus device (PFD) at pressures of 10, 15, 25, and 30 mbar using large-area polycarbonate track detectors (PCTDs) (15-cm etchable diameter) processed by 50-Hz-HV electrochemical etching (ECE). Helium ion track distributions at different pressures, in particular, at the main axis of the PFD are presented. Maximum ion track density of ~4.4 × 10{sup 4} tracks/cm{sup 2} was obtained in the PCTD placed 6 cm from the anode. The ion distributions for all pressures applied are ring-shaped, which is possibly due to the hollow cylindrical copper anode used. The large-area PCTD processed by ECE proves, at the present state-of-theart, a superior method for direct observation and analysis of ion distributions at a glance with minimum efforts and time. Some observations of the ion density distributions at different pressures are reported and discussed.

  11. An innovative, sensorless, pulsatile, continuous-flow total artificial heart: device design and initial in vitro study.

    Science.gov (United States)

    Fukamachi, Kiyotaka; Horvath, David J; Massiello, Alex L; Fumoto, Hideyuki; Horai, Tetsuya; Rao, Santosh; Golding, Leonard A R

    2010-01-01

    We are developing a very small, innovative, continuous-flow total artificial heart (CFTAH) that passively self-balances left and right pump flows and atrial pressures without sensors. This report details the CFTAH design concept and our initial in vitro data. System performance of the CFTAH was evaluated using a mock circulatory loop to determine the range of systemic and pulmonary vascular resistance (SVR and PVR) levels over which the design goal of a maximum absolute atrial pressure difference of 10 mm Hg is achieved for a steady-state flow condition. Pump speed was then modulated at 2,600 +/- 900 rpm to induce flow and arterial pressure pulsation to evaluate the effects of speed pulsations on the system performance. An automatic control mode was also evaluated. Using only passive self-regulation, pump flows were balanced and absolute atrial pressure differences were maintained at mode adjusted pump speed to achieve targeted pump flows based on sensorless calculations of SVR and CFTAH flow. The initial in vitro testing of the CFTAH with a single, valveless, continuous-flow pump demonstrated its passive self-regulation of flows and atrial pressures and a new automatic control mode. Copyright (c) 2010 International Society for Heart and Lung Transplantation. Published by Elsevier Inc. All rights reserved.

  12. Achievement report on research and development in the Sunshine Project in fiscal 1977. Studies on hydrogen energy total systems and the safety assuring technologies thereon (Studies on preparing criteria for the safety assuring technologies for hydrogen energy total systems); 1977 nendo suiso energy total system to sono hoan gijutsu ni kansuru kenkyu seika hokokusho. Suiso energy total system no hoan gijutsu kijun no sakusei ni kansuru kenkyu

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1978-03-01

    Studies have been made on preparing criteria for the safety assuring technologies for hydrogen energy total systems. The outline of the technological guideline for hydrogen manufacturing processes in the high temperature and pressure water decomposition method is the same as that in the normal pressure water decomposition method. However, its high temperature and pressure environment can cause new safety problems. Considerations should be given on, for example, material problems in structural materials and insulation materials including electrodes and membranes, introduction of gas-liquid separation and pressure balancing devices, problems in electrolyte circulation, and safety problems that may occur because of generation of hydrogen and oxygen under high temperature and pressure conditions. This paper summarizes these matters by surveying literature data. In order to provide basic information to prepare criteria for safety assuring technologies for the gaseous hydrogen liquefaction process, surveys and studies were made based on different items of technological information and experimental study results. Safety assuring technologies were discussed on metal hydrides (promising means for storing hydrogen). Powder is used to enhance hydrogen absorbing performance, whereas the metal hydrides are pulverized as a result of repetition of absorption and discharge of hydrogen. This paper describes also metal dust explosion disaster and its risk of occurrence. (NEDO)

  13. Does the suction drain diameter matter? Bleeding analysis after total knee replacement comparing different suction drain gauges

    Directory of Open Access Journals (Sweden)

    Marcos George de Souza Leao

    Full Text Available ABSTRACT OBJECTIVES: To evaluate bleeding and the estimated blood loss in patients who underwent total knee replacement (TKR with different closed suction drains (3.2-mm and 4.8-mm gauge. METHODS: This was a randomized controlled trial with 22 patients who underwent TKR and were divided into two groups: Group I, with 11 patients in whom the 3.2-mm suction drain was used, and Group II, with 11 patients in whom the 4.8-mm suction drain was used. The hematocrit was measured after 24, 48 and 72 h after surgery in order to calculate the estimated blood loss. The drained volume was measured 3, 6, 12, 24, and 48 h after TKR, and thereafter both groups were compared. RESULTS: Regarding the hematocrit, there were no differences between groups in measured periods (24, 48, and 72 h after surgery. The total bleeding measured at the suction drains within 48 h was higher in Group II, with a statistically significant difference (p = 0.005; in the first 24 h, there was major bleeding in Group II (mean 893 mL, with a significant difference (p = 0.004. Between 24 and 48 h, there was no statistically significant difference in both groups (p = 0.710. The total estimated bleeding was higher in Group I, with mean of 463 mL, versus 409 mL in Group II, with no statistical significance (p = 0.394. CONCLUSIONS: Bleeding was higher in the group that used the 4.8 mm gauge suction drain, with no differences in hematocrit and estimated blood loss.

  14. An electrokinetic pressure sensor

    International Nuclear Information System (INIS)

    Kim, Dong-Kwon; Kim, Sung Jin; Kim, Duckjong

    2008-01-01

    A new concept for a micro pressure sensor is demonstrated. The pressure difference between the inlet and the outlet of glass nanochannels is obtained by measuring the electrokinetically generated electric potential. To demonstrate the proposed concept, experimental investigations are performed for 100 nm wide nanochannels with sodium chloride solutions having various concentrations. The proposed pressure sensor is able to measure the pressure difference within a 10% deviation from linearity. The sensitivity of the electrokinetic pressure sensor with 10 −5 M sodium chloride solution is 18.5 µV Pa −1 , which is one order of magnitude higher than that of typical diaphragm-based pressure sensors. A numerical model is presented for investigating the effects of the concentration and the channel width on the sensitivity of the electrokinetic pressure sensor. Numerical results show that the sensitivity increases as the concentration decreases and the channel width increases

  15. Cathode fall thickness of abnormal glow discharges between parallel-plane electrodes in different radii at low pressure

    Energy Technology Data Exchange (ETDEWEB)

    Fu, Yangyang; Luo, Haiyun; Zou, Xiaobing; Wang, Xinxin, E-mail: wangxx@tsinghua.edu.cn [Department of Electrical Engineering, Tsinghua University, Beijing 100084 (China)

    2015-02-15

    In order to investigate the influence of electrode radius on the characteristics of cathode fall thickness, experiments of low-pressure (20 Pa ≤ p ≤ 30 Pa) abnormal glow discharge were carried out between parallel-plane electrodes in different radii keeping gap distance unchanged. Axial distributions of light intensity were obtained from the discharge images captured using a Charge Coupled Device camera. The assumption that the position of the negative glow peak coincides with the edge of cathode fall layer was verified based on a two-dimensional model, and the cathode fall thicknesses, d{sub c}, were calculated from the axial distributions of light intensity. It was observed that the position of peak emission shifts closer to the cathode as current or pressure grows. The dependence of cathode fall thickness on the gas pressure and normalized current J/p{sup 2} was presented, and it was found that for discharges between electrodes in large radius the curves of pd{sub c} against J/p{sup 2} were superimposed on each other, however, this phenomenon will not hold for discharges between the smaller electrodes. The reason for this phenomenon is that the transverse diffusions of charged particles are not the same in two gaps between electrodes with different radii.

  16. The elastic properties, generalized stacking fault energy and dissociated dislocations in MgB2 under different pressure

    KAUST Repository

    Feng, Huifang

    2013-05-31

    The 〈112̄0〉 perfect dislocation in MgB2 is suggested to dissociate into two partial dislocations in an energy favorable way 〈112̄0〉 → 1/2 〈112̄0〉 + SF + 1/2 〈112̄0〉. This dissociation style is a correction of the previous dissociation 〈1000〉 → 1/3 〈11̄00〉 SF + 1/3 〈 2100〉proposed by Zhu et al. to model the partial dislocations and stacking fault observed by transmission electron microscopy. The latter dissociation results in a maximal stacking fault energy rather than a minimal one according to the generalized stacking fault energy calculated from first-principles methods. Furthermore, the elastic constants and anisotropy of MgB2 under different pressure are investigated. The core structures and mobilities of the 〈112̄0〉 dissociated dislocations are studied within the modified Peierls-Nabarro (P-N) dislocation theory. The variational method is used to solve the modified P-N dislocation equation and the Peierls stress is also determined under different pressure. High pressure effects on elastic anisotropy, core structure and Peierls stress are also presented. © 2013 Springer Science+Business Media New York.

  17. Evaluation of the Function and Quality of Life after Total Hip Arthroplasty by Different Approaches

    Directory of Open Access Journals (Sweden)

    Paulo Araújo

    2017-09-01

    Conclusion: After 24 months post total hip arthroplasty there are no differences between the two approaches with regard to function or quality of life. However, the patients operated by the anterolateral approach had greater muscle strength deficits and higher percentage of positive Trendelenburg test.

  18. Ethnic differences of intraocular pressure and central corneal thickness: the Singapore Epidemiology of Eye Diseases study.

    Science.gov (United States)

    Chua, Jacqueline; Tham, Yih Chung; Liao, Jiemin; Zheng, Yingfeng; Aung, Tin; Wong, Tien Yin; Cheng, Ching-Yu

    2014-10-01

    To determine the ethnic differences in the distribution of intraocular pressure (IOP) and central corneal thickness (CCT) in a multi-ethnic Asian population by self-reported ethnicity and genetic ancestry. Population-based, cross-sectional study. A total of 10 033 adults (3353 Chinese, 3280 Malays, and 3400 Indians) aged >40 years. Participants underwent standardized systemic and ocular examinations and interviewer-administered questionnaires for risk factor assessment. The IOP readings were obtained by Goldmann applanation tonometry (Haag-Streit, Konig, Switzerland) before pupil dilation. The CCT was measured with ultrasound pachymetry. Genetic ancestry was derived using principal component (PC) analysis. Regression models were used to investigate the association of IOP and CCT with potential risk factors and genetic ancestry. Intraocular pressure and CCT. After excluding participants with a history of glaucoma surgery or medication, refractive surgery, corneal edema, or corneal dystrophy, IOP and CCT readings were available for 3251 Chinese, 3232 Malays, and 3317 Indians. The mean IOP readings in the Chinese, Malay, and Indian participants were 14.3±3.1, 15.3±3.7, and 15.8±2.9 mmHg, respectively (P Chinese, 6.2% in Malays, and 4% in Indians (P Malay and Indian participants on average had 0.81 and 1.43 mmHg higher IOP levels, respectively, than Chinese (P Chinese, 540.9±33.6 μm in Malays, and 540.4±33.6 μm in Indians (P Chinese, 68.5% in Malays, and 66.2% in Indians (P Chinese have the thickest CCT but lowest IOP among the 3 major ethnic groups. In addition, there is a higher proportion of Malays with IOP ≥21 mmHg and CCT Chinese or Indians. This disparity across ethnic groups should be taken into account by future studies investigating IOP and CCT as risk factors or diagnostic tests for glaucoma in Asian populations. Copyright © 2014 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  19. Human Milk MicroRNA and Total RNA Differ Depending on Milk Fractionation.

    Science.gov (United States)

    Alsaweed, Mohammed; Hepworth, Anna R; Lefèvre, Christophe; Hartmann, Peter E; Geddes, Donna T; Hassiotou, Foteini

    2015-10-01

    MicroRNA have been recently discovered in human milk signifying potentially important functions for both the lactating breast and the infant. Whilst human milk microRNA have started to be explored, little data exist on the evaluation of sample processing, and analysis to ensure that a full spectrum of microRNA can be obtained. Human milk comprises three main fractions: cells, skim milk, and lipids. Typically, the skim milk fraction has been measured in isolation despite evidence that the lipid fraction may contain more microRNA. This study aimed to standardize isolation of microRNA and total RNA from all three fractions of human milk to determine the most appropriate sampling and analysis procedure for future studies. Three different methods from eight commercially available kits were tested for their efficacy in extracting total RNA and microRNA from the lipid, skim, and cell fractions of human milk. Each fraction yielded different concentrations of RNA and microRNA, with the highest quantities found in the cell and lipid fractions, and the lowest in skim milk. The column-based phenol-free method was the most efficient extraction method for all three milk fractions. Two microRNAs were expressed and validated in the three milk fractions by qPCR using the three recommended extraction kits for each fraction. High expression levels were identified in the skim and lipid milk factions for these microRNAs. These results suggest that careful consideration of both the human milk sample preparation and extraction protocols should be made prior to embarking upon research in this area. © 2015 The Authors. Journal of Cellular Biochemistry Published by Wiley Periodicals, Inc.

  20. Study on a linear relationship between limited pressure difference and coil current of on/off valve and its influential factors.

    Science.gov (United States)

    Zhang, Junzhi; Lv, Chen; Yue, Xiaowei; Li, Yutong; Yuan, Ye

    2014-01-01

    On/off solenoid valves with PWM control are widely used in all types of vehicle electro-hydraulic control systems respecting to their desirable properties of reliable, low cost and fast acting. However, it can hardly achieve a linear hydraulic modulation by using on/off valves mainly due to the nonlinear behaviors of valve dynamics and fluid, which affects the control accuracy significantly. In this paper, a linear relationship between limited pressure difference and coil current of an on/off valve in its critical closed state is proposed and illustrated, which has a great potential to be applied to improve hydraulic control performance. The hydraulic braking system of case study is modeled. The linear correspondence between limited pressure difference and coil current of the inlet valve is simulated and further verified experimentally. Based on validated simulation models, the impacts of key parameters are researched. The limited pressure difference affected by environmental temperatures is experimentally studied, and the amended linear relation is given according to the test data. © 2013 ISA. Published by Elsevier Ltd. All rights reserved.

  1. The association between serum uric acid and blood pressure in different age groups in a healthy Chinese cohort.

    Science.gov (United States)

    Cheng, Wenjuan; Wen, Shiling; Wang, Yutang; Qian, Zhiping; Tan, Yuyao; Li, Hongying; Hou, Yueli; Hu, Haiyang; Golledge, Jonathan; Yang, Guang

    2017-12-01

    High serum uric acid (sUA) has been reported to be a risk factor for hypertension however, whether this is the case for all age groups is not clear. We examined the association between sUA concentrations and systolic and diastolic blood pressure (SBP and DBP) in different age groups in a cohort of healthy Chinese participants.A total of 1082 healthy participants aged from 41 to 70 years were included. sUA concentration was measured by the uricase-peroxidase method. SBP and DBP were assessed using mercury sphygmomanometry. Hypertension was defined as SBP ≥140 mm Hg or DBP ≥90 mm Hg. Hyperuricemia (HUA) was defined as sUA concentration of >7 mg/dL in men and >6 mg/dL in women. The association between sUA concentration and SBP and DBP was examined using Pearson's correlation test, multivariate linear regression, and logistic regression analysis.The prevalence of hypertension and HUA increased with age (P age, sex, total cholesterol, estimated glomerular filtration rate, and fasting plasma glucose). HUA was also a risk factor for hypertension in this age group (odds ratio 1.425, 95% confidence interval, 1.217-1.668, P age groups.In this population of healthy Chinese participants, sUA concentration was positively associated with hypertension only in the 41- to 50-year-old group. Lowering uric acid in this age group may help to reduce the incidence of hypertension. Copyright © 2017 The Authors. Published by Wolters Kluwer Health, Inc. All rights reserved.

  2. Hydropyrolysis of a Turkish lignite (Tuncbilek) and effect of temperature and pressure on product distribution

    Energy Technology Data Exchange (ETDEWEB)

    Canel, M.; Misirlioglu, Z.; Sinag, A. [Ankara University, Ankara (Turkey). Faculty of Science

    2005-08-01

    The hydropyrolysis of a Turkish lignite (Tuncbilek) in a swept fixed bed reactor connected with a thermo-balance was performed at a heating rate of 3 C/min up to 950 C under 0.5MPa, 1MPa and 10MPa hydrogen pressures. The formation rates of gaseous hydrocarbons, carbon oxides, water and tar were determined. The difference between the weight loss due to tar formation of the non-condensable total and the weight loss of the sample recorded continuously with the thermo-balance showed the corresponding curve of tar formation rate as a function of temperature. It was shown that the total conversion and the formation rate of the products during hydropyrolysis could be influenced by varying the pressure. On the other hand, the volatile matter evolved during pyrolysis was substantially increased in the presence of hydrogen and especially when elevated hydrogen pressure was used.

  3. Intraocular pressure measurement in patients with previous LASIK surgery using pressure phosphene tonometer.

    Science.gov (United States)

    Cheng, Arthur C K; Leung, Dexter Y L; Cheung, Eva Y Y; Fan, Dorothy S P; Law, Ricky W K; Lam, Dennis S C

    2005-04-01

    To compare intraocular pressure (IOP) assessment in post-LASIK patients using non-contact tonometry, pressure phosphene tonometry and applanation tonometry. Sixty-two consecutive LASIK patients were analysed preoperatively and postoperatively with non-contact, pressure phosphene and applanation tonometry. Comparisons among these values were assessed with paired sample Student t-test, Pearson's correlation test and Bland-Altman plotting. There was no significant difference for preoperative IOP measurement between non-contact, pressure phosphene and applanation tonometry. The mean +/-SD difference between the preoperative non-contact tonometry and postoperative pressure phosphene tonometry IOP measurements was 0.80 +/- 2.77 mmHg (P contact tonometry significantly underestimated IOP measurement by 9.96 +/- 2.25 mmHg (P < 0.001). Pressure phosphene tonometry may provide an alternative method for the assessment of IOP in post-LASIK patients.

  4. Intra-abdominal pressure during swimming.

    Science.gov (United States)

    Moriyama, S; Ogita, F; Huang, Z; Kurobe, K; Nagira, A; Tanaka, T; Takahashi, H; Hirano, Y

    2014-02-01

    The present study aimed to determine the intra-abdominal pressure during front crawl swimming at different velocities in competitive swimmers and to clarify the relationships between stroke indices and changes in intra-abdominal pressure. The subjects were 7 highly trained competitive collegiate male swimmers. Intra-abdominal pressure was measured during front crawl swimming at 1.0, 1.2 and 1.4 m · s(-1) and during the Valsalva maneuver. Intra-abdominal pressure was taken as the difference between minimum and maximum values, and the mean of 6 stable front crawl stroke cycles was used. Stroke rate and stroke length were also measured as stroke indices. There were significant differences in stroke rate among all velocities (P pressure and stroke rate or stroke length (P pressure and stroke indices when controlling for swimming velocity. These findings do not appear to support the effectiveness of trunk training performed by competitive swimmers aimed at increasing intra-abdominal pressure. © Georg Thieme Verlag KG Stuttgart · New York.

  5. The effect of different unstable footwear constructions on centre of pressure motion during standing.

    Science.gov (United States)

    Plom, W; Strike, S C; Taylor, M J D

    2014-06-01

    The aim of this study was to test the effect different unstable footwear constructions have on centre of pressure motion when standing. Sixteen young female volunteers were tested in five conditions, three unstable footwear (Reebok Easy-Tone, FitFlop and Skechers Shape-Ups), a standard shoe and barefoot in a randomised order. Double and single leg balance on a force plate was assessed via centre of pressure excursions and displacements in each condition. For double leg and single leg standing centre of pressure excursions in the anterior-posterior direction were significantly increased wearing Skechers Shape-Ups compared to barefoot and the standard shoe. For the Reebok Easy Tone during single leg standing excursions in the anterior-posterior direction were significantly greater compared to the barefoot condition. Cumulative displacement of the centre of pressure in medial-lateral direction increased significantly during single leg standing when wearing Skechers Shape-Ups compared to barefoot and standard shoe as well as for Reebok Easy Tone vs. barefoot. It would appear from these quiet standing results that the manner of the construction of instability shoes effects the CoP movement which is associated with induced instability. Greater CoP excursion occurred in the A-P direction while the cumulative displacements were greater in the M-L direction for those shoes with the rounded sole and soft foam and those with airpods. The shoe construction with altered density foam did not induce any change in the CoP movement, during quite standing, which tends to suggest that it is not effective at inducing balance. Not all instability shoes are effective in altering the overall instability of the wearer. Copyright © 2014 Elsevier B.V. All rights reserved.

  6. Effects of ambient temperature and water vapor on chamber pressure and oxygen level during low atmospheric pressure stunning of poultry.

    Science.gov (United States)

    Holloway, Paul H; Pritchard, David G

    2017-08-01

    The characteristics of the vacuum used in a low atmospheric pressure stunning system to stun (render unconscious) poultry prior to slaughter are described. A vacuum chamber is pumped by a wet screw compressor. The vacuum pressure is reduced from ambient atmospheric pressure to an absolute vacuum pressure of ∼250 Torr (∼33 kPa) in ∼67 sec with the vacuum gate valve fully open. At ∼250 Torr, the sliding gate valve is partially closed to reduce effective pumping speed, resulting in a slower rate of decreasing pressure. Ambient temperature affects air density and water vapor pressure and thereby oxygen levels and the time at the minimum total pressure of ∼160 Torr (∼21 kPa) is varied from ∼120 to ∼220 sec to ensure an effective stun within the 280 seconds of each cycle. The reduction in total pressure results in a gradual reduction of oxygen partial pressure that was measured by a solid-state electrochemical oxygen sensor. The reduced oxygen pressure leads to hypoxia, which is recognized as a humane method of stunning poultry. The system maintains an oxygen concentration of air always reduces the oxygen concentrations to a value lower than in dry air. The partial pressure of water and oxygen were found to depend on the pump down parameters due to the formation of fog in the chamber and desorption of water from the birds and the walls of the vacuum chamber. © The Author 2017. Published by Oxford University Press on behalf of Poultry Science Association.

  7. Corrosion kinetics at high pressure and temperature of Zr-2.5 Nb with different heat treatments

    International Nuclear Information System (INIS)

    Jaime Solis, F.; Bordoni, Roberto; Olmedo, Ana M.; Villegas, Marina; Miyagusuku, Marcela

    2003-01-01

    The corrosion behaviour of Zr-2.5 Nb pressure tube (PT) specimens, with ageing treatments at 400 and 500 C degrees for different times, was studied. The results were analyzed using the corrosion behavior of Zr-20 Nb and Zr-1 Nb samples heat treated during 1 hour at 850 C degrees, cooled in air and aged at the same temperature and times than the PT specimens. The comparison between the corrosion behaviour of Zr-1 Nb and Zr-20 Nb aged coupons with the aged pressure tube specimens, together with the metal/oxide interface morphology of Zr-2.5 Nb specimens, suggest that the increase in the corrosion resistance in the latter coupons is associated with the decomposition of the β-Zr phase. There is also a contribution of α-Zr phase when the ageing temperatures are high enough or the ageing times are long enough, due to a decrease in the Nb content of this phase. This last contribution is associated with an increase in the corrosion resistance of the central zone of pressure tube in the reactor. (author)

  8. The plant-specific impact of different pressurization rates in the probabilistic estimation of containment failure modes

    International Nuclear Information System (INIS)

    Ahn, Kwang Il; Yang, Joon Eon; Ha, Jae Joo

    2003-01-01

    The explicit consideration of different pressurization rates in estimating the probabilities of containment failure modes has a profound effect on the confidence of containment performance evaluation that is so critical for risk assessment of nuclear power plants. Except for the sophisticated NUREG-1150 study, many of the recent containment performance analyses (through level 2 PSAs or IPE back-end analyses) did not take into account an explicit distinction between slow and fast pressurization in their analyses. A careful investigation of both approaches shows that many of the approaches adopted in the recent containment performance analyses exactly correspond to the NUREG-1150 approach for the prediction of containment failure mode probabilities in the presence of fast pressurization. As a result, it was expected that the existing containment performance analysis results would be subjected to greater or less conservatism in light of the ultimate failure mode of the containment. The main purpose of this paper is to assess potential conservatism of a plant-specific containment performance analysis result in light of containment failure mode probabilities

  9. High pressure phase transformations revisited

    Science.gov (United States)

    Levitas, Valery I.

    2018-04-01

    High pressure phase transformations play an important role in the search for new materials and material synthesis, as well as in geophysics. However, they are poorly characterized, and phase transformation pressure and pressure hysteresis vary drastically in experiments of different researchers, with different pressure transmitting media, and with different material suppliers. Here we review the current state, challenges in studying phase transformations under high pressure, and the possible ways in overcoming the challenges. This field is critically compared with fields of phase transformations under normal pressure in steels and shape memory alloys, as well as plastic deformation of materials. The main reason for the above mentioned discrepancy is the lack of understanding that there is a fundamental difference between pressure-induced transformations under hydrostatic conditions, stress-induced transformations under nonhydrostatic conditions below yield, and strain-induced transformations during plastic flow. Each of these types of transformations has different mechanisms and requires a completely different thermodynamic and kinetic description and experimental characterization. In comparison with other fields the following challenges are indicated for high pressure phase transformation: (a) initial and evolving microstructure is not included in characterization of transformations; (b) continuum theory is poorly developed; (c) heterogeneous stress and strain fields in experiments are not determined, which leads to confusing material transformational properties with a system behavior. Some ways to advance the field of high pressure phase transformations are suggested. The key points are: (a) to take into account plastic deformations and microstructure evolution during transformations; (b) to formulate phase transformation criteria and kinetic equations in terms of stress and plastic strain tensors (instead of pressure alone); (c) to develop multiscale continuum

  10. High pressure phase transformations revisited.

    Science.gov (United States)

    Levitas, Valery I

    2018-04-25

    High pressure phase transformations play an important role in the search for new materials and material synthesis, as well as in geophysics. However, they are poorly characterized, and phase transformation pressure and pressure hysteresis vary drastically in experiments of different researchers, with different pressure transmitting media, and with different material suppliers. Here we review the current state, challenges in studying phase transformations under high pressure, and the possible ways in overcoming the challenges. This field is critically compared with fields of phase transformations under normal pressure in steels and shape memory alloys, as well as plastic deformation of materials. The main reason for the above mentioned discrepancy is the lack of understanding that there is a fundamental difference between pressure-induced transformations under hydrostatic conditions, stress-induced transformations under nonhydrostatic conditions below yield, and strain-induced transformations during plastic flow. Each of these types of transformations has different mechanisms and requires a completely different thermodynamic and kinetic description and experimental characterization. In comparison with other fields the following challenges are indicated for high pressure phase transformation: (a) initial and evolving microstructure is not included in characterization of transformations; (b) continuum theory is poorly developed; (c) heterogeneous stress and strain fields in experiments are not determined, which leads to confusing material transformational properties with a system behavior. Some ways to advance the field of high pressure phase transformations are suggested. The key points are: (a) to take into account plastic deformations and microstructure evolution during transformations; (b) to formulate phase transformation criteria and kinetic equations in terms of stress and plastic strain tensors (instead of pressure alone); (c) to develop multiscale continuum

  11. Total donor ischemic time: relationship to early hemodynamics and intensive care morbidity in pediatric cardiac transplant recipients.

    Science.gov (United States)

    Rodrigues, Warren; Carr, Michelle; Ridout, Deborah; Carter, Katherine; Hulme, Sara Louise; Simmonds, Jacob; Elliott, Martin; Hoskote, Aparna; Burch, Michael; Brown, Kate L

    2011-11-01

    Single-center studies have failed to link modest increases in total donor ischemic time to mortality after pediatric orthotopic heart transplant. We aimed to investigate whether prolonged total donor ischemic time is linked to pediatric intensive care morbidity after orthotopic heart transplant. Retrospective cohort review. Tertiary pediatric transplant center in the United Kingdom. Ninety-three pediatric orthotopic heart transplants between 2002 and 2006. Total donor ischemic time was investigated for association with early post-orthotopic heart transplant hemodynamics and intensive care unit morbidities. Of 43 males and 50 females with median age 7.2 (interquartile range 2.2, 13.0) yrs, 62 (68%) had dilated cardiomyopathy, 20 (22%) had congenital heart disease, and nine (10%) had restrictive cardiomyopathy. The mean total donor ischemic time was 225.9 (sd 65.6) mins. In the first 24 hrs after orthotopic heart transplant, age-adjusted mean arterial blood pressure increased (p total donor ischemic time was significantly associated with lower mean arterial blood pressure (p care unit (p = .004), and longer post-orthotopic heart transplant stay in hospital (p = .02). Total donor ischemic time was not related to levels of mean pulmonary arterial pressure (p = .62), left atrial pressure (p = .38), or central venous pressure (p = .76) early after orthotopic heart transplant. Prolonged total donor ischemic time has an adverse effect on the donor organ, contributing to lower mean arterial blood pressure, as well as more prolonged ventilation and intensive care unit and hospital stays post-orthotopic heart transplant, reflecting increased morbidity.

  12. Reliability of Center of Pressure Parameters in Postural Sway among Athlete and Non-athlete Men in Different Levels of Fatigue and Vision

    Directory of Open Access Journals (Sweden)

    Zohreh Meshkati

    2010-10-01

    Full Text Available Objective: This study aimed to investigate the skill, fatigue and vision-related differences between athletes and non-athletes in reliability of center of pressure (COP measures derived from force platform. Materials & Methods: Thirty-one healthy male participants (15 athletes and 16 non-athletes were tested on force platform on two sessions with a 48-72 hr interval. COP parameters was recorded during two-legged quiet standing before and after a generalized fatigue exercise by treadmill, with eyes-open (EO and eyes-closed (EC. Standard deviation (SD of amplitude, SD of velocity in anteroposterior (AP and mediolateral directions and mean total velocity were calculated from 30 sec COP data. Results: Higher intraclass correlation coefficient (ICC was found for COP measures in the athlete (compared with the non-athlete group. ICC was increased in post-fatigue (compared with pre-fatigue conditions. Also higher ICC was found for EC (compared with EO tests. Coefficients of variation smaller than 15% were obtained for most of the COP measures. Alpha level of 0. 05 was considered for all statistical analyses. Regarding the level of skill, fatigue and vision, mean total velocity (P=0. 001 and SD of velocity (AP (P=0. 001 were the most reliable parameters. Conclusion: The results aid researchers in selection of reliable COP measures for future studies of postural control in sports. In this way, researchers can use mean total velocity and SD of velocity (AP parameters in their studies in same conditions on athletes.

  13. REGULATION OF BLOOD PRESSURE IN PATIENTS WITH PRIMARY HYPERTENSION WITH SMOOTHIE BANANA (MUSA PARADISIACA

    Directory of Open Access Journals (Sweden)

    Eni Puji Lestari

    2017-04-01

    Full Text Available Introduction: Hypertension is a major problem that often happen in Indonesia. Hypertension can cause many complications. In Indonesia almost patients with hypertension got farmacologic therapy, but there is no difference. Banana smoothie is one of nonfarmacologic therapy that can be used to lower blood pressure. The purpose of this study was to analyze the effect of banana smoothie on regulation in patients with primary hypertension. Method: This study used quasy experimental design. The population in this study were patients with primary hypertension in Kedungturi village Taman Sidoarjo. The sampling technique used nonprobability sampling type of purposive sampling. The total number of sample were 16 respondents who were selected based on inclusion and exclusion criteria. Result:The Result of paired t-test at the systolic blood pressure and diastolic blood pressure in experiment group showed p value = 0.000. Independent t test between experiment group post-test and control group post-test showed p value = 0.000 for systolic blood pressure and p value = 0.002 for diastolic blood pressure. This result showed that there was a difference value of pretest and post-test systolic and diastolic blood pressure. With the result of independen t-test we know that there is a difference value between exsperiment and control blood pressure. Discussion: This study explain that there was significant effect of banana smoothie to regulate blood pressure in patients with primary hypertention. Banana smoothie can regulate the blood pressure because of high kalium substance. The function of kalium is to reduce the effect of natrium so the blood pressure can down. It can be conclude that banana smoothie can regulate the blood pressure in patients with primary hypertention. In further day patients with hypertension can choose banana smoothie to regulate their blood pressure.

  14. Effective production of bioenergy from marine Chlorella sp. by high-pressure homogenization

    Directory of Open Access Journals (Sweden)

    Woon Yong Choi

    2016-01-01

    Full Text Available This study investigated the use of a high-pressure homogenization process for the production of high shear stress on Chlorella sp. cells in order to effectively degrade their cell walls. The high-pressure homogenization process was conducted by using various pressure conditions in the range of 68.94–275.78 MPa with different numbers of repeated cycles. The optimal high-pressure homogenization pretreatment conditions were found to be two cycles at a pressure of 206.84 MPa, which provided an extraction yield of 20.35% (w/w total cellular lipids. In addition, based on the confocal microscopic images of Chlorella sp. cells stained by using nile red, the walls of Chlorella sp. cells were disrupted more effectively using this process when compared with the disruption achieved by conventional lipid-extraction processes. By using the by-product of Chlorella sp., 47.3% ethanol was obtained from Saccharomyces cerevisiae cultures. These results showed that the high-pressure homogenization process efficiently hydrolysed this marine resource for subsequent bioethanol production by using only water.

  15. Plantar Pressures During Long Distance Running: An Investigation of 10 Marathon Runners

    Directory of Open Access Journals (Sweden)

    Erik Hohmann, Peter Reaburn, Kevin Tetsworth, Andreas Imhoff

    2016-06-01

    Full Text Available The objective of this study was to record plantar pressures using an in-shoe measuring system before, during, and after a marathon run in ten experienced long-distance runners with a mean age of 37.7 ± 11.5 years. Peak and mean plantar pressures were recorded before, after, and every three km during a marathon race. There were no significant changes over time in peak and mean plantar pressures for either the dominant or non-dominant foot. There were significant between foot peak and mean plantar pressure differences for the total foot (p = 0.0001, forefoot (p = 0.0001, midfoot (p = 0.02 resp. p = 0.006, hindfoot (p = 0.0001, first ray (p = 0.01 resp. p = 0.0001 and MTP (p = 0.05 resp. p = 0.0001. Long-distance runners do not demonstrate significant changes in mean or peak plantar foot pressures over the distance of a marathon race. However, athletes consistently favoured their dominant extremity, applying significantly higher plantar pressures through their dominant foot over the entire marathon distance.

  16. Dietary protein and blood pressure : epidemiological studies

    NARCIS (Netherlands)

    Altorf-van der Kuil, W.

    2012-01-01


    Background
    Elevated blood pressure is a major risk factor for cardiovascular diseases. Diet and lifestyle have a substantial impact on blood pressure, but the role of protein intake is not yet clear. This thesis focuses on total dietary protein, types of protein (i.e. plant and

  17. Analysis of temperature difference on the total of energy expenditure during static bicycle exercise

    Science.gov (United States)

    Sugiono

    2016-04-01

    How to manage energy expenditure for cyclist is very crucial part to achieve a good performance. As the tropical situation, the differences of temperature level might be contributed in energy expenditure and durability. The aim of the paper is to estimate and to analysis the configuration of energy expenditure for static cycling activity based on heart rate value in room with air conditioning (AC)/no AC treatment. The research is started with study literatures of climate factors, temperature impact on human body, and definition of energy expenditure. The next step is design the experiment for 5 participants in 2 difference models for 26.80C - 74% relative humidity (room no AC) and 23,80C - 54.8% relative humidity (room with AC). The participants’ heart rate and blood pressure are measured in rest condition and in cycling condition to know the impact of difference temperature in energy expenditure profile. According to the experiment results, the reducing of the temperature has significantly impact on the decreasing of energy expenditure at average 0.3 Kcal/minute for all 5 performers. Finally, the research shows that climate condition (temperature and relative humidity) are very important factors to manage and to reach a higher performance of cycling sport.

  18. Comparative effects of different dietary approaches on blood pressure in hypertensive and pre-hypertensive patients: A systematic review and network meta-analysis.

    Science.gov (United States)

    Schwingshackl, Lukas; Chaimani, Anna; Schwedhelm, Carolina; Toledo, Estefania; Pünsch, Marina; Hoffmann, Georg; Boeing, Heiner

    2018-05-02

    Pairwise meta-analyses have shown beneficial effects of individual dietary approaches on blood pressure but their comparative effects have not been established. Therefore we performed a systematic review of different dietary intervention trials and estimated the aggregate blood pressure effects through network meta-analysis including hypertensive and pre-hypertensive patients. PubMed, Cochrane CENTRAL, and Google Scholar were searched until June 2017. The inclusion criteria were defined as follows: i) Randomized trial with a dietary approach; ii) hypertensive and pre-hypertensive adult patients; and iii) minimum intervention period of 12 weeks. In order to determine the pooled effect of each intervention relative to each of the other intervention for both diastolic and systolic blood pressure (SBP and DBP), random effects network meta-analysis was performed. A total of 67 trials comparing 13 dietary approaches (DASH, low-fat, moderate-carbohydrate, high-protein, low-carbohydrate, Mediterranean, Palaeolithic, vegetarian, low-GI/GL, low-sodium, Nordic, Tibetan, and control) enrolling 17,230 participants were included. In the network meta-analysis, the DASH, Mediterranean, low-carbohydrate, Palaeolithic, high-protein, low-glycaemic index, low-sodium, and low-fat dietary approaches were significantly more effective in reducing SBP (-8.73 to -2.32 mmHg) and DBP (-4.85 to -1.27 mmHg) compared to a control diet. According to the SUCRAs, the DASH diet was ranked the most effective dietary approach in reducing SBP (90%) and DBP (91%), followed by the Palaeolithic, and the low-carbohydrate diet (ranked 3rd for SBP) or the Mediterranean diet (ranked 3rd for DBP). For most comparisons, the credibility of evidence was rated very low to moderate, with the exception for the DASH vs. the low-fat dietary approach for which the quality of evidence was rated high. The present network meta-analysis suggests that the DASH dietary approach might be the most effective dietary measure

  19. Method transfer from high-pressure liquid chromatography to ultra-high-pressure liquid chromatography. II. Temperature and pressure effects.

    Science.gov (United States)

    Åsberg, Dennis; Samuelsson, Jörgen; Leśko, Marek; Cavazzini, Alberto; Kaczmarski, Krzysztof; Fornstedt, Torgny

    2015-07-03

    The importance of the generated temperature and pressure gradients in ultra-high-pressure liquid chromatography (UHPLC) are investigated and compared to high-pressure liquid chromatography (HPLC). The drug Omeprazole, together with three other model compounds (with different chemical characteristics, namely uncharged, positively and negatively charged) were used. Calculations of the complete temperature profile in the column at UHPLC conditions showed, in our experiments, a temperature difference between the inlet and outlet of 16 °C and a difference of 2 °C between the column center and the wall. Through van't Hoff plots, this information was used to single out the decrease in retention factor (k) solely due to the temperature gradient. The uncharged solute was least affected by temperature with a decrease in k of about 5% while for charged solutes the effect was more pronounced, with k decreases up to 14%. A pressure increase of 500 bar gave roughly 5% increase in k for the uncharged solute, while omeprazole and the other two charged solutes gave about 25, 20 and 15% increases in k, respectively. The stochastic model of chromatography was applied to estimate the dependence of the average number of adsorption/desorption events (n) and the average time spent by a molecule in the stationary phase (τs) on temperature and pressure on peak shape for the tailing, basic solute. Increasing the temperature yielded an increase in n and decrease in τs which resulted in less skew at high temperatures. With increasing pressure, the stochastic modeling gave interesting results for the basic solute showing that the skew of the peak increased with pressure. The conclusion is that pressure effects are more pronounced for both retention and peak shape than the temperature effects for the polar or charged compounds in our study. Copyright © 2015 Elsevier B.V. All rights reserved.

  20. Interarm blood pressure difference and target organ damage in the general population.

    Science.gov (United States)

    Johansson, Jouni K; Puukka, Pauli J; Jula, Antti M

    2014-02-01

    The objective of the study was to investigate interarm differences of blood pressure (BP) and its determinants, and to clarify whether both arms are equally good in assessing BP and target organ damage in the general population. We studied a representative sample of Finnish adult population with 484 study participants, ages 25-74 years. BP was measured twice by an oscillometric monitor simultaneously on both arms. Study participants underwent a clinical examination including measurements of serum lipids, glucose and indicators of target organ damage. BP was 2.3/0.2 mmHg higher on right than on left arm (P differences). SBP and DBP measured on right and left arms correlated equally with left ventricular mass index (LVMI), interventricular septal thickness (IVST), posterior wall thickness (PWT), pulse wave velocity (PWV) and albuminuria. Higher SBP level was an independent determinant of both greater systolic and diastolic interarm BP difference. Exaggerated absolute diastolic interarm BP difference (>5 mmHg) was associated with higher BMI, arm circumference, LVMI, IVST and PWT, whereas exaggerated absolute systolic interarm BP difference (>10 mmHg) was not associated with any clinical variables. There was only a small difference in BP between arms in a healthy general population. Both arms are equally good determinants of target organ damage. BP should be measured at least once on both arms and prefer the arm with higher BP readings in the future BP measurements.

  1. Fluorinert as a pressure-transmitting medium for high-pressure diffraction studies

    International Nuclear Information System (INIS)

    Varga, Tamas; Wilkinson, Angus P.; Angel, Ross J.

    2003-01-01

    Fluorinert is a liquid pressure-transmitting medium that is widely used in high-pressure diffraction work. A systematic study of five different fluorinerts was carried out using single-crystal x-ray diffraction in a diamond-anvil cell in order to determine the pressure range over which they provide a hydrostatic stress state to the sample. It was found that none of the fluorinerts studied can be considered hydrostatic above 1.2 GPa, a lower pressure than reported previously

  2. Analysis of French (Paluel) pressurized water reactor design differences compared to current US PWR designs

    International Nuclear Information System (INIS)

    1986-05-01

    To understand better the regulatory approaches to reactor safety in foreign countries, the staff of the Nuclear Regulatory Commisssion has reviewed design information on the Paluel nuclear power plant, one of the current standard 1300-MWe plant operating in France. This report provides the staff's evaluation of major design differences between this standardized French plant and current US pressurized water reactor plants, as well as insights concerning French regulatory practices. The staff identified approximately 25 design differences, and an analysis of the safety significance of each of these design features is presented, along with an assessment comparing the relative safety benefit of each

  3. On the permanent hip-stabilizing effect of atmospheric pressure.

    Science.gov (United States)

    Prietzel, Torsten; Hammer, Niels; Schleifenbaum, Stefan; Kaßebaum, Eric; Farag, Mohamed; von Salis-Soglio, Georg

    2014-08-22

    Hip joint dislocations related to total hip arthroplasty (THA) are a common complication especially in the early postoperative course. The surgical approach, the alignment of the prosthetic components, the range of motion and the muscle tone are known factors influencing the risk of dislocation. A further factor that is discussed until today is atmospheric pressure which is not taken into account in the present THA concepts. The aim of this study was to investigate the impact of atmospheric pressure on hip joint stability. Five joint models (Ø 28-44 mm), consisting of THA components were hermetically sealed with a rubber capsule, filled with a defined amount of fluid and exposed to varying ambient pressure. Displacement and pressure sensors were used to record the extent of dislocation related to intraarticular and ambient pressure. In 200 experiments spontaneous dislocations of the different sized joint models were reliably observed once the ambient pressure was lower than 6.0 kPa. Increasing the ambient pressure above 6.0 kPa immediately and persistently reduced the joint models until the ambient pressure was lowered again. Displacement always exceeded half the diameter of the joint model and was independent of gravity effects. This experimental study gives strong evidence that the hip joint is permanently stabilized by atmospheric pressure, confirming the theories of Weber and Weber (1836). On basis of these findings the use of larger prosthetic heads, capsular repair and the deployment of an intracapsular Redon drain are proposed to substantially decrease the risk of dislocation after THA. Copyright © 2014 Elsevier Ltd. All rights reserved.

  4. Methyl mercury, but not inorganic mercury, associated with higher blood pressure during pregnancy.

    Science.gov (United States)

    Wells, Ellen M; Herbstman, Julie B; Lin, Yu Hong; Hibbeln, Joseph R; Halden, Rolf U; Witter, Frank R; Goldman, Lynn R

    2017-04-01

    Prior studies addressing associations between mercury and blood pressure have produced inconsistent findings; some of this may result from measuring total instead of speciated mercury. This cross-sectional study of 263 pregnant women assessed total mercury, speciated mercury, selenium, and n-3 polyunsaturated fatty acids in umbilical cord blood and blood pressure during labor and delivery. Models with a) total mercury or b) methyl and inorganic mercury were evaluated. Regression models adjusted for maternal age, race/ethnicity, prepregnancy body mass index, neighborhood income, parity, smoking, n-3 fatty acids and selenium. Geometric mean total, methyl, and inorganic mercury concentrations were 1.40µg/L (95% confidence interval: 1.29, 1.52); 0.95µg/L (0.84, 1.07); and 0.13µg/L (0.10, 0.17), respectively. Elevated systolic BP, diastolic BP, and pulse pressure were found, respectively, in 11.4%, 6.8%, and 19.8% of mothers. In adjusted multivariable models, a one-tertile increase of methyl mercury was associated with 2.83mmHg (0.17, 5.50) higher systolic blood pressure and 2.99mmHg (0.91, 5.08) higher pulse pressure. In the same models, an increase of one tertile of inorganic mercury was associated with -1.18mmHg (-3.72, 1.35) lower systolic blood pressure and -2.51mmHg (-4.49, -0.53) lower pulse pressure. No associations were observed with diastolic pressure. There was a non-significant trend of higher total mercury with higher systolic blood pressure. We observed a significant association of higher methyl mercury with higher systolic and pulse pressure, yet higher inorganic mercury was significantly associated with lower pulse pressure. These results should be confirmed with larger, longitudinal studies. Copyright © 2017 Elsevier Inc. All rights reserved.

  5. Numerical Simulation of Damage during Forging with Superimposed Hydrostatic Pressure by Active Media

    International Nuclear Information System (INIS)

    Behrens, B.-A.; Hagen, T.; Roehr, S.; Sidhu, K. B.

    2007-01-01

    The effective reduction of energy consumption and a reasonable treatment of resources can be achieved by minimizing a component's weight using lightweight metals. In this context, aluminum alloys play a major role. Due to their material-sided restricted formability, the mentioned aluminum materials are difficult to form. The plasticity of a material is ascertained by its maximum forming limit. It is attained, when the deformation causes mechanical damage within the material. Damage of that sort is reached more rapidly, the greater the tensile strength rate in relation to total tension rate. A promising approach of handling these low ductile, high-strength aluminum alloys within a forming process, is forming with a synchronized superposition of comprehensive stress by active media such as by controlling oil pressure. The influence of superimposed hydrostatic pressure on the flow stress was analyzed as well as the formability for different procedures at different hydrostatic pressures and temperature levels. It was observed that flow stress is independent of superimposed hydrostatic pressure. Neither the superimposed pressure has an influence on the plastic deformation, nor does a pressure dependent material hardening due to increasing hydrostatic pressure take place. The formability increases with rising hydrostatic pressure. The relative gain at room temperature and increase of the superimposed pressure from 0 to 600 bar for tested materials was at least 140 % and max. 220 %. Therefore in this paper, based on these experimental observations, it is the intended to develop a numerical simulation in order to predict ductile damage that occurs in the bulk forging process with superimposed hydrostatic pressure based Lemaitre's damage model

  6. Sewage sludge disintegration by high-pressure homogenization: a sludge disintegration model.

    Science.gov (United States)

    Zhang, Yuxuan; Zhang, Panyue; Ma, Boqiang; Wu, Hao; Zhang, Sheng; Xu, Xin

    2012-01-01

    High-pressure homogenization (HPH) technology was applied as a pretreatment to disintegrate sewage sludge. The effects of homogenization pressure, homogenization cycle number, and total solid content on sludge disintegration were investigated. The sludge disintegration degree (DD(COD)), protein concentration, and polysaccharide concentration increased with the increase of homogenization pressure and homogenization cycle number, and decreased with the increase of sludge total solid (TS) content. The maximum DD(COD) of 43.94% was achieved at 80 MPa with four homogenization cycles for a 9.58 g/L TS sludge sample. A HPH sludge disintegration model of DD(COD) = kNaPb was established by multivariable linear regression to quantify the effects of homogenization parameters. The homogenization cycle exponent a and homogenization pressure exponent b were 0.4763 and 0.7324 respectively, showing that the effect of homogenization pressure (P) was more significant than that of homogenization cycle number (N). The value of the rate constant k decreased with the increase of sludge total solid content. The specific energy consumption increased with the increment of sludge disintegration efficiency. Lower specific energy consumption was required for higher total solid content sludge.

  7. Gender, race, age, and regional differences in the association of pulse pressure with atrial fibrillation: the Reasons for Geographic and Racial Differences in Stroke study.

    Science.gov (United States)

    Ghazi, Lama; Safford, Monika M; Khodneva, Yulia; O'Neal, Wesley T; Soliman, Elsayed Z; Glasser, Stephen P

    2016-08-01

    Pulse pressure (PP) has been associated with atrial fibrillation (AF) independent of other measures of arterial pressure and other AF risk factors. However, the impact of gender, race, age, and geographic region on the association between PP and AF is unclear. A cross-sectional study of data from 25,109 participants (65 ± 9 years, 54% women, 40% black) from the Reasons for Geographic and Racial Differences in Stroke study recruited between 2003 and 2007 were analyzed. AF was defined as a self-reported history of a previous physician diagnosis or presence of AF on ECG. Multivariable logistic regression models were used to calculate the odds ratio for AF. Interactions for age (race, and region were examined in the multivariable adjusted model. The prevalence of AF increased with widening PP (7.9%, 7.9%, 8.4%, and 11.6%, for PP differences by gender, race, and region were observed. However, there was evidence of significant effect modification by age (interaction P = .0002). For those differ for older versus younger individuals. Copyright © 2016 American Society of Hypertension. Published by Elsevier Inc. All rights reserved.

  8. Relationship between office and home blood pressure with increasing age: The International Database of HOme blood pressure in relation to Cardiovascular Outcome (IDHOCO).

    Science.gov (United States)

    Ntineri, Angeliki; Stergiou, George S; Thijs, Lutgarde; Asayama, Kei; Boggia, José; Boubouchairopoulou, Nadia; Hozawa, Atsushi; Imai, Yutaka; Johansson, Jouni K; Jula, Antti M; Kollias, Anastasios; Luzardo, Leonella; Niiranen, Teemu J; Nomura, Kyoko; Ohkubo, Takayoshi; Tsuji, Ichiro; Tzourio, Christophe; Wei, Fang-Fei; Staessen, Jan A

    2016-08-01

    Home blood pressure (HBP) measurements are known to be lower than conventional office blood pressure (OBP) measurements. However, this difference might not be consistent across the entire age range and has not been adequately investigated. We assessed the relationship between OBP and HBP with increasing age using the International Database of HOme blood pressure in relation to Cardiovascular Outcome (IDHOCO). OBP, HBP and their difference were assessed across different decades of age. A total of 5689 untreated subjects aged 18-97 years, who had at least two OBP and HBP measurements, were included. Systolic OBP and HBP increased across older age categories (from 112 to 142 mm Hg and from 109 to 136 mm Hg, respectively), with OBP being higher than HBP by ∼7 mm Hg in subjects aged >30 years and lesser in younger subjects (P=0.001). Both diastolic OBP and HBP increased until the age of ∼50 years (from 71 to 79 mm Hg and from 66 to 76 mm Hg, respectively), with OBP being consistently higher than HBP and a trend toward a decreased OBP-HBP difference with aging (P<0.001). Determinants of a larger OBP-HBP difference were younger age, sustained hypertension, nonsmoking and negative cardiovascular disease history. These data suggest that in the general adult population, HBP is consistently lower than OBP across all the decades, but their difference might vary between age groups. Further research is needed to confirm these findings in younger and older subjects and in hypertensive individuals.

  9. Differences in blood pressure measurements in the forearm and upper arm of obese otherwise healthy first year medical students

    Directory of Open Access Journals (Sweden)

    Suganthi V, Navin Rajaratnam, Suzanne Maria D’cruz

    2014-07-01

    Full Text Available Background: The prevalence of obesity is increasing in Indian youth and obesity is associated with complications like systemic hypertension. Often, due to the non-availability of appropriate sized cuffs, standard cuff bladders are used to measure blood pressure in the forearms of obese young adults. Aim: To compare the upper arm arterial blood pressure measured using an appropriate cuff with the forearm arterial blood pressure measured using a standard cuff and conventional sphygmomanometry in obese otherwise healthy first year medical students. Materials and Methods: Blood pressure was measured in 27 obese otherwise healthy first year medical students after five minutes of rest using a mercury sphygmomanometer with the subjects seated and the arm and forearm at heart level, using an appropriate sized cuff for the upper arm according to American Heart Association standards and a standard cuff for the fore arm. Results: A statistically significant difference in both systolic [t-test (paired = -6.921; df = 26; sig = .000 (2- tailed] and diastolic blood pressure [t-test (paired = -8.508; df = 26; sig = .000 (2- tailed] was found, with the blood pressure readings being higher in the forearm. The correlations between upper arm and forearm systolic and diastolic blood pressure were 0.785 (p = .000 and 0.870 (p = .000. Conclusion: Both systolic and diastolic blood pressure measurements were significantly higher in the forearm. Further studies with larger sample size should be conducted to confirm that forearm blood pressure measurements using standard cuff bladders cannot be considered equal to upper arm measurements made using an appropriate sized cuff in all young obese individuals

  10. Intraocular pressure measurement by three different tonometers in primary congenital glaucoma.

    Science.gov (United States)

    Zareei, Athar; Razeghinejad, Mohammad Reza; Nowroozzadeh, Mohammad Hosein; Mehrabi, Yadollah; Aghazadeh-Amiri, Mohammad

    2015-01-01

    To determine the agreement between intraocular pressure (IOP) measurements using an automated non-contact tonometer (NCT), Goldmann applanation tonometer (GAT), and the ocular response analyzer (ORA) in subjects with primary congenital glaucoma (PCG). Twenty-nine eyes of 17 PCG patients underwent IOP measurements using NCT, GAT and ORA. Variables obtained by the ORA were corneal-compensated IOP (IOPcc), Goldmann-correlated IOP (IOPg), corneal hysteresis (CH), and corneal resistance factor (CRF). A difference more than 1.5 mmHg for IOP was considered as clinically relevant. Mean age of the patients was 12 years. Mean IOP (±standard deviation, SD) was 15.3 ± 2.8 mmHg (GAT), 15.5 ± 6.0 (NCT), 19.2 ± 7.0 (IOPg), and 21.1 ± 7.9 (IOPcc); (P = 0.001). Except for NCT vs. GAT (P = 1.0), the average IOP difference between each pair of measurements was clinically relevant. The 95% limits of agreements were - 10.2 to 10.3 mmHg (NCT vs. GAT), -7.8 to 15.3 (IOPg vs. GAT), and - 8.1 to 19.0 (IOPcc vs. GAT). The differences in IOP measurements increased significantly with higher average IOP values (r = 0.715, P = 0.001, for NCT vs. GAT; r = 0.802, P < 0.001, for IOPg vs. GAT; and r = 0.806, P < 0.001, for IOPcc vs. GAT). CH showed a significant association with differences in IOP measurements only for IOPcc vs. GAT (r = 0.830, P < 0.001). Mean IOP obtained by NCT was not significantly different from that of GAT, but ORA measured IOPs were significantly higher than both other devices.

  11. Numerical Modeling of MILD Combustion at High Pressure to Predict the Optimal Operating Conditions

    KAUST Repository

    Vanteru, Mahendra Reddy

    2017-02-01

    This Chapter presents numerical simulation on MILD combustion operating at high pressure. Influence of preheat and dilution of oxidizer and operating pressure on stabilization of MILD combustion are presented. Three different preheat temperatures (1100, 1300 and 1500 K) and three different dilution levels (3, 6 and 9% O2) are simulated over an operating pressure variation from 1 atm to 16 atm. A classical jet in hot coflow burner is considered for this study. Total of 45 cases are simulated and analyzed. Essential characteristics of MILD combustion, i.e., maximum temperature (Tmax), temperature rise (ΔT) and temperature distributions, are analyzed. The distribution of emissions OH and CO are also studied and presented. Well-stabilized MILD combustion is observed for all cases except for two cases with high preheated (1500 K). Peak temperature is observed to decrease with increasing operating pressure for a given level of preheat and dilution. OH mass faction is reduced with increasing pressure. The CO emissions show little sensitivity to operating pressure. However, CO mass fraction is slightly higher at 1 atm operating pressure as compared to 4 to 16 atm. Since the residence time of reactants increases as the operating pressure increases, well-stabilized MILD combustion is observed for all highly diluted and low temperature preheat cases (3% O2 and 1100 K).

  12. Numerical Modeling of MILD Combustion at High Pressure to Predict the Optimal Operating Conditions

    KAUST Repository

    Vanteru, Mahendra Reddy; Roberts, William L.

    2017-01-01

    This Chapter presents numerical simulation on MILD combustion operating at high pressure. Influence of preheat and dilution of oxidizer and operating pressure on stabilization of MILD combustion are presented. Three different preheat temperatures (1100, 1300 and 1500 K) and three different dilution levels (3, 6 and 9% O2) are simulated over an operating pressure variation from 1 atm to 16 atm. A classical jet in hot coflow burner is considered for this study. Total of 45 cases are simulated and analyzed. Essential characteristics of MILD combustion, i.e., maximum temperature (Tmax), temperature rise (ΔT) and temperature distributions, are analyzed. The distribution of emissions OH and CO are also studied and presented. Well-stabilized MILD combustion is observed for all cases except for two cases with high preheated (1500 K). Peak temperature is observed to decrease with increasing operating pressure for a given level of preheat and dilution. OH mass faction is reduced with increasing pressure. The CO emissions show little sensitivity to operating pressure. However, CO mass fraction is slightly higher at 1 atm operating pressure as compared to 4 to 16 atm. Since the residence time of reactants increases as the operating pressure increases, well-stabilized MILD combustion is observed for all highly diluted and low temperature preheat cases (3% O2 and 1100 K).

  13. Assessing intravascular volume by difference in pulse pressure in pigs submitted to graded hemorrhage.

    Science.gov (United States)

    Pestel, Gunther J; Hiltebrand, Luzius B; Fukui, Kimiko; Cohen, Delphine; Hager, Helmut; Kurz, Andrea M

    2006-10-01

    We assessed changes in intravascular volume monitored by difference in pulse pressure (dPP%) after stepwise hemorrhage in an experimental pig model. Six pigs (23-25 kg) were anesthetized (isoflurane 1.5 vol%) and mechanically ventilated to keep end-tidal CO2 (etCO2) at 35 mmHg. A PA-catheter and an arterial catheter were placed via femoral access. During and after surgery, animals received lactated Ringer's solution as long as they were considered volume responders (dPP>13%). Then animals were allowed to stabilize from the induction of anesthesia and insertion of catheters for 30 min. After stabilization, baseline measurements were taken. Five percent of blood volume was withdrawn, followed by another 5%, and then in 10%-increments until death from exsanguination occurred. After withdrawal of 5% of blood volume, all pigs were considered volume responders (dPP>13%); dPP rose significantly from 6.1+/-3.3% to 19.4+/-4.2%. The regression analysis of stepwise hemorrhage revealed a linear relation between blood loss (hemorrhage in %) and dPP (y=0.99*x+14; R2=0.7764; P<.0001). In addition, dPP was the only parameter that changed significantly between baseline and a blood loss of 5% (P<0.01), whereas cardiac output, stroke volume, heart rate, MAP, central venous pressure, pulmonary artery occlusion pressure, and systemic vascular resistance, respectively, remained unchanged. We conclude that in an experimental hypovolemic pig model, dPP correlates well with blood loss.

  14. Simultaneous inter-arm and inter-leg systolic blood pressure differences to diagnose peripheral artery disease: a diagnostic accuracy study.

    Science.gov (United States)

    Herráiz-Adillo, Ángel; Soriano-Cano, Alba; Martínez-Hortelano, José Alberto; Garrido-Miguel, Miriam; Mariana-Herráiz, Julián Ángel; Martínez-Vizcaíno, Vicente; Notario-Pacheco, Blanca

    2018-04-01

    Inter-arm systolic blood pressure differences (IASBPD) and inter-leg systolic blood pressure differences (ILSBPD) have arisen as potential tools to detect peripheral artery disease (PAD) and individuals at high cardiovascular risk. This study aims to evaluate the diagnostic accuracy of IASBPD and ILSBPD to detect PAD, and whether IASBPD or ILSBPD improves diagnostic accuracy of the oscillometric ankle-brachial index (ABI). In this prospective study, eligible for inclusion were consecutive adults, with at least one of the following cardiovascular risk factors: diabetes, dyslipidemia, hypertension, smoking habit or age ≥65. IASBPD, ILSBPD and ankle-brachial index (ABI) were measured in all participants through four-limb simultaneous oscillometric measurements and compared with Doppler ABI (reference test, positive cut-off: ≤ 0.9). Of 171 subjects included, PAD was confirmed in 23 and excluded in 148. Thirteen and 38 subjects had IASBPD and ILSBPD ≥10 mmHg, respectively. Pearson correlation with Doppler ABI of IASBPD and ILSBPD was 0.073 (P = .343) and -0.628 (P blood pressure measurements in upper limbs are not possible.

  15. Analysis for pressure transient of coalbed methane reservoir based on Laplace transform finite difference method

    OpenAIRE

    Lei Wang; Hongjun Yin; Xiaoshuang Yang; Chuncheng Yang; Jing Fu

    2015-01-01

    Based on fractal geometry, fractal medium of coalbed methane mathematical model is established by Langmuir isotherm adsorption formula, Fick's diffusion law, Laplace transform formula, considering the well bore storage effect and skin effect. The Laplace transform finite difference method is used to solve the mathematical model. With Stehfest numerical inversion, the distribution of dimensionless well bore flowing pressure and its derivative was obtained in real space. According to compare wi...

  16. Nonstationary pressure build up in full-pressure containments after a loss-of-coolant accident

    International Nuclear Information System (INIS)

    Mansfeld, G.

    1977-01-01

    The time histories of pressure, temperature and pressure difference during the pressure build up phase of a loss-of-coolant accident (LOCA) in the primary system in full-pressure containments of water cooled nuclear power reactors are treated. These are important for the design of such containments. The experiments within the German research program RS 50 ''Druckverteilung im Containment'' offered, for the first time, the opportunity to observe experimentally fluid-dynamic processes in a multiple divided full-pressure containment, and to test at the same time, computer codes which serve to describe the physical processes during the LOCA. The comparison of the results calculated by the computer codes ZOCO VI and DDIFF with the experimental results showed apparent deviations by special arrangements of the compartments and the vent flow paths of a model containment for the calculation of time dependent pressure-, temperature- and pressure difference-histories. The deviations lead to the development of the analytical model and computer code COFLOW. This new model was primarily designed to deal with the fluid-dynamic processes in the beginning phase of the blowdown as maximal pressure differences appear. Furthermore, it can be used to determine the maximum containment pressure, as well as for long term calculations. The analytical model and computer code COFLOW shows a better correlation between theory and experiment than previous codes

  17. First report of 90-day support of 2 calves with a continuous-flow total artificial heart.

    Science.gov (United States)

    Karimov, Jamshid H; Moazami, Nader; Kobayashi, Mariko; Sale, Shiva; Such, Kimberly; Byram, Nicole; Sunagawa, Gengo; Horvath, David; Gao, Shengqiang; Kuban, Barry; Golding, Leonard A R; Fukamachi, Kiyotaka

    2015-09-01

    The Cleveland Clinic continuous-flow total artificial heart (CFTAH) is a compact, single-piece, valveless, pulsatile pump providing self-regulated hemodynamic output to left/right circulation. We evaluated chronic in vivo pump performance, physiologic and hemodynamic parameters, and biocompatibility of the CFTAH in a well-established calf model. CFTAH pumps have been implanted in 17 calves total. Hemodynamic parameters, pump performance, and device-related adverse events were evaluated during studies and at necropsy. In vivo experiments demonstrated good hemodynamic performance (pump flow, 7.3 ± 0.7 L/min; left atrial pressure, 16 ± 3 mm Hg; right atrial pressure, 17 ± 3 mm Hg; right atrial pressure-left atrial pressure difference, 1 ± 2 mm Hg; mean arterial pressure, 103 ± 7 mm Hg; arterial pulse pressure, 30 ± 11 mm Hg; and pulmonary arterial pressure, 34 ± 5 mm Hg). The CFTAH has operated within design specifications and never failed. With ever-improving pump design, the implants have shown no chronic hemolysis. Three animals with recent CFTAH implantation recovered well, with no postoperative anticoagulation, during planned in vivo durations of 30, 90, and 90 days (last 2 were intended to be 90-day studies). All these longest-surviving cases showed good biocompatibility, with no thromboembolism in organs. The current CFTAH has demonstrated reliable self-regulation of hemodynamic output and acceptable biocompatibility without anticoagulation throughout 90 days of chronic implantation in calves. Meeting these milestones is in accord with our strategy to achieve transfer of this unique technology to human surgical practice, thus filling the urgent need for cardiac replacement devices as destination therapy. Copyright © 2015 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

  18. Parameters of the center of pressure displacement on the saddle during hippotherapy on different surfaces

    Directory of Open Access Journals (Sweden)

    Fabiana M. Flores

    2015-06-01

    Full Text Available Background: Hippotherapy uses horseback riding movements for therapeutic purposes. In addition to the horse's movement, the choice of equipment and types of floor are also useful in the intervention. The quantification of dynamic parameters that define the interaction of the surface of contact between horse and rider provides insight into how the type of floor surface variations act upon the subject's postural control. Objective: To test whether different types of surfaces promote changes in the amplitude (ACOP and velocity (VCOP of the center of pressure (COP displacement during the rider's contact with the saddle on the horse's back. Method: Twenty two healthy adult male subjects with experience in riding were evaluated. The penetration resistances of asphalt, sand and grass surfaces were measured. The COP data were collected on the three surfaces using a pressure measurement mat. Results: ACOP values were higher in sand, followed by grass and asphalt, with significant differences between sand and asphalt (anteroposterior, p=0.042; mediolateral, p=0.019. The ACOP and VCOP values were higher in the anteroposterior than in the mediolateral direction on all surfaces (ACOP, p=0.001; VCOP, p=0.006. The VCOP did not differ between the surfaces. Conclusion: Postural control, measured by the COP displacement, undergoes variations in its amplitude as a result of the type of floor surface. Therefore, these results reinforce the importance of the choice of floor surface when defining the strategy to be used during hippotherapy intervention.

  19. Parameters of the center of pressure displacement on the saddle during hippotherapy on different surfaces.

    Science.gov (United States)

    Flores, Fabiana M; Dagnese, Frederico; Mota, Carlos B; Copetti, Fernando

    2015-01-01

    Hippotherapy uses horseback riding movements for therapeutic purposes. In addition to the horse's movement, the choice of equipment and types of floor are also useful in the intervention. The quantification of dynamic parameters that define the interaction of the surface of contact between horse and rider provides insight into how the type of floor surface variations act upon the subject's postural control. To test whether different types of surfaces promote changes in the amplitude (ACOP) and velocity (VCOP) of the center of pressure (COP) displacement during the rider's contact with the saddle on the horse's back. Twenty two healthy adult male subjects with experience in riding were evaluated. The penetration resistances of asphalt, sand and grass surfaces were measured. The COP data were collected on the three surfaces using a pressure measurement mat. ACOP values were higher in sand, followed by grass and asphalt, with significant differences between sand and asphalt (anteroposterior, p=0.042; mediolateral, p=0.019). The ACOP and VCOP values were higher in the anteroposterior than in the mediolateral direction on all surfaces (ACOP, p=0.001; VCOP, p=0.006). The VCOP did not differ between the surfaces. Postural control, measured by the COP displacement, undergoes variations in its amplitude as a result of the type of floor surface. Therefore, these results reinforce the importance of the choice of floor surface when defining the strategy to be used during hippotherapy intervention.

  20. In vitro biomechanical comparison of three different types of single- and double-row arthroscopic rotator cuff repairs: analysis of continuous bone-tendon contact pressure and surface during different simulated joint positions.

    Science.gov (United States)

    Grimberg, Jean; Diop, Amadou; Kalra, Kunal; Charousset, Christophe; Duranthon, Louis-Denis; Maurel, Nathalie

    2010-03-01

    We assessed bone-tendon contact surface and pressure with a continuous and reversible measurement system comparing 3 different double- and single-row techniques of cuff repair with simulation of different joint positions. We reproduced a medium supraspinatus tear in 24 human cadaveric shoulders. For the 12 right shoulders, single-row suture (SRS) and then double-row bridge suture (DRBS) were used. For the 12 left shoulders, DRBS and then double-row cross suture (DRCS) were used. Measurements were performed before, during, and after knot tying and then with different joint positions. There was a significant increase in contact surface with the DRBS technique compared with the SRS technique and with the DRCS technique compared with the SRS or DRBS technique. There was a significant increase in contact pressure with the DRBS technique and DRCS technique compared with the SRS technique but no difference between the DRBS technique and DRCS technique. The DRCS technique seems to be superior to the DRBS and SRS techniques in terms of bone-tendon contact surface and pressure. Copyright 2010 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.

  1. Analysis of different anthropometric indicators in the detection of high blood pressure in school adolescents: a cross-sectional study with 8295 adolescents.

    Science.gov (United States)

    Christofaro, Diego G D; Farah, Breno Q; Vanderlei, Luiz Carlos M; Delfino, Leandro D; Tebar, William R; Barros, Mauro Virgílio G de; Ritti-Dias, Raphael M

    High blood pressure is strongly associated with obesity in different populations. However, it is unclear whether different anthropometric indicators of obesity can satisfactorily predict high blood pressure in the school setting. This study evaluated the sensitivity and specificity of body mass index, waist circumference, and waist to height ratio in the detection of high blood pressure in adolescents. The sample consisted of 8295 adolescents aged 10-17 years. Weight was measured using a digital scale, height with a stadiometer, and waist circumference using a tape measure. Blood pressure was measured by an automatic blood pressure measuring device. ROC curves were used for the analysis of sensitivity and specificity of the three anthropometric indices in identifying high blood pressure. Binary Logistic Regression was used to assess the association of body mass index, waist circumference, and waist to height ratio with high blood pressure. Low values of sensitivity were observed for body mass index (0.35), waist circumference (0.37), and waist to height ratio (0.31) and high values of specificity for body mass index (0.86), waist circumference (0.82), and waist to height ratio (0.83) in the detection of high blood pressure. An association was observed between adolescents classified with high body mass index (OR=3.57 [95% CI=3.10-4.10]), waist cirumference (OR=3.24 [95% CI=2.83-3.72]), and waist to height ratio (OR=2.94 [95% CI=2.54-3.40]) with high blood pressure. Body mass index, waist circumference, and waist to height ratio presented low sensitivity to identify adolescents with high blood pressure. However, adolescents classified with high body mass index, waist circumference, and waist to height ratio demonstrated a high association of presenting high blood pressure. Copyright © 2017 Associação Brasileira de Pesquisa e Pós-Graduação em Fisioterapia. Publicado por Elsevier Editora Ltda. All rights reserved.

  2. [Factors affecting the pressure distribution underneath the foot sole in ski boots].

    Science.gov (United States)

    Schaff, P; Kulot, M; Hauser, W; Rosemeyer, B

    1988-12-01

    The determination of pressure patterns underneath the footsole inside skiboots, may reveal reasons for footpain and injury risk. In our study, a new developed 72 point measuring mat was used in 5 different skiboots. Data were collected in 10 subjects in different forward flexion positions. In addition a determination of the pressure distribution over the instep was done by means of single measuring points. The results proof, that a proper adapting along the dorsum of the foot does lower the forefoot load during flexion. A tightly closed and well adapted boot will lead to a significant reduction of the total load on the footsole. High shaft models show similar pressure patterns even at earlier forward flexion angles. A pressure related discrimination between rear entry and traditional boots, that was found along the tibia, was not the case underneath the footsole. The force transmission is mainly performed along the shaft of the boot. The effect of orthotics designed mainly to support steerability of the ski, is therefore doubtful. The results may help to improve our knowledge of the interaction between boot and skier and lead, together with future field research, to a reduction of equipment related injuries.

  3. [Effects of pressure induced retinal ischemia on ERG in rabbit].

    Science.gov (United States)

    Song, G; Yang, X; Zhang, Z; Zhang, D

    2001-12-01

    To observe the effects of pressure induced retinal ischemia on electroretinogram(ERG) in rabbit. Retinal ischemia was induced in rabbits by increasing intraocular pressure at 30 mmHg, 60 mmHg, 90 mmHg, 120 mmHg for 45 minutes, and retinal function was monitored by eletroretinography. There was no difference on ERG before or after the experiment both in 30 mmHg group and control one. In 60 mmHg pressure induced ischemia eyes, the amplitudes of the b-wave and OPs wave reduced significantly. Four hours after reperfusion, they were totally recovered. After an ischemic insult of 90 mmHg or 120 mmHg for 45 minutes, there was no response of ERG. Four hours later, the amplitudes of the b-wave and OPs wave were 66.912 +/- 20.157 and 16.423 +/- 3.965 the former, 38.852 +/- 23.438 and 8.610 +/- 12.090 the latter, respectively. These results suggest that higher intraocular pressure causes more severe retina ischemic damage, and less recovery ability.

  4. Computational model for transient studies of IRIS pressurizer behavior

    International Nuclear Information System (INIS)

    Rives Sanz, R.; Montesino Otero, M.E.; Gonzalez Mantecon, J.; Rojas Mazaira, L.

    2014-01-01

    International Reactor Innovative and Secure (IRIS) excels other Small Modular Reactor (SMR) designs due to its innovative characteristics regarding safety. IRIS integral pressurizer makes the design of larger pressurizer system than the conventional PWR, without any additional cost. The IRIS pressurizer volume of steam can provide enough margins to avoid spray requirement to mitigate in-surge transient. The aim of the present research is to model the IRIS pressurizer's dynamic using the commercial finite volume Computational Fluid Dynamic code CFX 14. A symmetric tridimensional model equivalent to 1/8 of the total geometry was adopted to reduce mesh size and minimize processing time. The model considers the coexistence of three phases: liquid, steam, and vapor bubbles in liquid volume. Additionally, it takes into account the heat losses between the pressurizer and primary circuit. The relationships for interfacial mass, energy, and momentum transport are programmed and incorporated into CFX by using expressions in CFX Command Language (CCL) format. Moreover, several additional variables are defined for improving the convergence and allow monitoring of boron dilution sequences and condensation-evaporation rate in different control volumes. For transient states a non - equilibrium stratification in the pressurizer is considered. This paper discusses the model developed and the behavior of the system for representative transients sequences such as the in/out-surge transients and boron dilution sequences. The results of analyzed transients of IRIS can be applied to the design of pressurizer internal structures and components. (author)

  5. Reduction of peak plantar pressure in people with diabetes-related peripheral neuropathy: an evaluation of the DH Pressure Relief Shoe™

    Directory of Open Access Journals (Sweden)

    Raspovic Anita

    2012-10-01

    Full Text Available Abstract Background Offloading plantar pressure is a key strategy for the prevention or healing of neuropathic plantar ulcers in diabetes. Non-removable walking casts, such as total contact casts, are currently considered the gold-standard for offloading this type of wound. However, alternative methods for offloading that are more cost effective and easier to use are continually being sought. The aim of this study was to evaluate the capacity of the DH Pressure Relief Shoe™ to offload high pressure areas under the neuropathic foot in diabetes. Methods A within-subjects, repeated measures design was used. Sixteen participants with diabetic peripheral neuropathy were recruited and three footwear conditions were evaluated in a randomised order: a canvas shoe (the control, the participants’ own standard shoe, and the DH Pressure Relief Shoe™. The primary outcome was peak plantar pressure, measured using the pedar-X® mobile in-shoe system between the three conditions. Results Data analysis was conducted on 14 out of the 16 participants because two participants could not complete data collection. The mean peak pressure values in kPa (±SD for each condition were: control shoe 315.9 (±140.7, participants’ standard shoe 273.0 (±127.1 and DH Pressure Relief Shoe™ 155.4 (±89.9. There was a statistically significant difference in peak plantar pressure between the DH Pressure Relief Shoe™ compared to both the control shoe (p = 0.002 and participants’ standard shoe (p = 0.001. The DH Pressure Relief Shoe™ decreased plantar pressures by 51% compared to the control shoe and by 43% compared to participants’ standard shoe. Importantly, for a couple of study participants, the DH Pressure Relief Shoe™ appeared unsuitable for day-to-day wearing. Conclusions The DH Pressure Relief Shoe™ reduced plantar pressures more than the other two shoe conditions. The DH Pressure Relief Shoe™ may be a useful alternative to current offloading

  6. Sources of dietary protein in relation to blood pressure in a general Dutch population

    NARCIS (Netherlands)

    Altorf-van der Kuil, W.; Engberink, M.F.; Vedder, M.M.; Boer, J.M.A.; Verschuren, W.M.M.; Geleijnse, J.M.

    2012-01-01

    Background - Little is known about the relation of different dietary protein types with blood pressure (BP). We examined whether intake of total, plant, animal, dairy, meat, and grain protein was related to BP in a cross sectional cohort of 20,820 Dutch adults, aged 20–65 y and not using

  7. BIOMECHANICAL INDICES OF STANDING AND GAIT IN PATIENTS AFTER TOTAL KNEE REPLACEMENT USING COMPUTER NAVIGATION

    Directory of Open Access Journals (Sweden)

    Y. A. Bezgodkov

    2011-01-01

    Full Text Available Several biomechanical parameters of standing and walking in 50 patients with osteoarthrosis after total knee arthroplasty were evaluated. The patients were randomly divided in two equal groups: in the first group the surgery was performed with computer navigation system and in the second - with traditional instruments. After TKA with computer navigation centers of common body pressure and legs pressure during standing phase improved significantly better than in traditional group. Walking parameters like step length, ground contact time and rhythm coefficient improved in both groups of patients but without significant difference. Thereby more precise orientation of implant that achieved during computer assisted TKA leads to better functional performance at 6 and 12 month after surgery.

  8. Pressure Profiles in a Loop Heat Pipe under Gravity Influence

    Science.gov (United States)

    Ku, Jentung

    2015-01-01

    During the operation of a loop heat pipe (LHP), the viscous flow induces pressure drops in various elements of the loop. The total pressure drop is equal to the sum of pressure drops in vapor grooves, vapor line, condenser, liquid line and primary wick, and is sustained by menisci at liquid and vapor interfaces on the outer surface of the primary wick in the evaporator. The menisci will curve naturally so that the resulting capillary pressure matches the total pressure drop. In ground testing, an additional gravitational pressure head may be present and must be included in the total pressure drop when LHP components are placed in a non-planar configuration. Under gravity-neutral and anti-gravity conditions, the fluid circulation in the LHP is driven solely by the capillary force. With gravity assist, however, the flow circulation can be driven by the combination of capillary and gravitational forces, or by the gravitational force alone. For a gravity-assist LHP at a given elevation between the horizontal condenser and evaporator, there exists a threshold heat load below which the LHP operation is gravity driven and above which the LHP operation is capillary force and gravity co-driven. The gravitational pressure head can have profound effects on the LHP operation, and such effects depend on the elevation, evaporator heat load, and condenser sink temperature. This paper presents a theoretical study on LHP operations under gravity-neutral, anti-gravity, and gravity-assist modes using pressure diagrams to help understand the underlying physical processes. Effects of the condenser configuration on the gravitational pressure head and LHP operation are also discussed.

  9. Optimum back-pressure forging using servo die cushion

    OpenAIRE

    Kawamoto, Kiichiro; Yoneyama, Takeshi; Okada, Masato; Kitayama, Satoshi; Chikahisa, Junpei

    2014-01-01

    This study focused on utilizing a servo die cushion (in conjunction with a servo press) as a "back-pressure load generator," to determine its effect on shape accuracy of the formed part and total forming load in forward extrusion during cold forging. The effect of back-pressure load application was confirmed in experiments, and the optimum setting pattern of back-pressure load was considered to minimize both shape accuracy of the formed part and back-pressure energy, which was representative ...

  10. Accumulation of total mercury and methylmercury in rice plants collected from different mining areas in China

    International Nuclear Information System (INIS)

    Meng, Mei; Li, Bing; Shao, Jun-juan; Wang, Thanh; He, Bin; Shi, Jian-bo; Ye, Zhi-hong; Jiang, Gui-bin

    2014-01-01

    A total of 155 rice plants were collected from ten mining areas in three provinces of China (Hunan, Guizhou and Guangdong), where most of mercury (Hg) mining takes place in China. During the harvest season, whole rice plants were sampled and divided into root, stalk and leaf, husk and seed (brown rice), together with soil from root zone. Although the degree of Hg contamination varied significantly among different mining areas, rice seed showed the highest ability for methylmercury (MeHg) accumulation. Both concentrations of total mercury (THg) and MeHg in rice plants were significantly correlated with Hg levels in soil, indicating soil is still an important source for both inorganic mercury (IHg) and MeHg in rice plants. The obvious discrepancy between the distribution patterns of THg and MeHg reflected different pathways of IHg and MeHg accumulation. Water soluble Hg may play more important role in MeHg accumulation in rice plants. -- Highlights: • Distribution patterns indicated different pathways of IHg and MeHg accumulation. • Soil is an important source for both THg and MeHg to rice plants. • Water soluble Hg may play more important role in MeHg accumulation in rice plants. -- The distribution patterns indicate different pathways of IHg and MeHg accumulation in rice plants

  11. A CROSS SECTIONAL STUDY TO FIND THE DIFFERENCE IN SYSTOLIC BLOOD PRESSURE BETWEEN ARMS AS A RISK MARKER FOR DIABETIC NEPHROPATHY IN PATIENTS WITH TYPE 2 DIABETES MELLITUS

    Directory of Open Access Journals (Sweden)

    Uday Subhash Bande

    2016-08-01

    Full Text Available BACKGROUND Diabetic nephropathy is the commonest cause of end-stage renal disease in the developed world. Recent studies have demonstrated that a difference in systolic blood pressure between arms is associated with cardiovascular disease and microalbuminuria. It is considered a predictor for cardiovascular disease and a surrogate marker for early kidney damage among patients with both type 2 diabetes and hypertension. AIMS AND OBJECTIVES The aim was to investigate an association between arm difference in systolic blood pressure and microalbuminuria which can serve as a marker for diabetic nephropathy. MATERIALS AND METHOD This study was conducted on 200 patients with diabetes mellitus and an inter-arm difference in systolic blood pressure was present in 35.7% of the study population. Presence of systolic blood pressure difference of more than 10 mmHg between arms correlated with microalbuminuria and duration of diabetes mellitus with a p value of <0.001. We also found a correlation between arm difference in blood pressure and duration of diabetes mellitus, presence of hypertension and body mass index. CONCLUSION The inter-arm difference in blood pressure could serve as a risk marker for renal damage in diabetes mellitus.

  12. Differences in perioperative femoral and radial arterial blood pressure in neonates and infants undergoing cardiac surgery requiring cardiopulmonary bypass

    Directory of Open Access Journals (Sweden)

    Hwa Jin Cho

    2018-01-01

    Full Text Available Objective: Several reports claim that blood pressure (BP in the radial artery may underestimate the accurate BP in critically ill patients. Here, the authors evaluated differences in mean blood pressure (MBP between the radial and femoral artery during pediatric cardiac surgery to determine the effectiveness of femoral arterial BP monitoring. Method: The medical records of children under 1 year of age who underwent open-heart surgery between 2007 and 2013 were retrospectively reviewed. Radial and femoral BP were measured simultaneously, and the differences between these values were analyzed at various times: after catheter insertion, after the initiation of cardiopulmonary bypass (CPB-on, after aortic cross clamping (ACC, after the release of ACC, after weaning from CPB, at arrival in the intensive care unit (ICU, and every 6 h during the first day in the ICU. Results: A total of 121 patients who underwent open-heart surgery met the inclusion criteria. During the intraoperative period, from the beginning to the end of CPB, radial MBPs were significantly lower than femoral MBPs at each time-point measured (p 60 min, odds ratio: 7.47 was a risk factor for lower radial pressure. However, discrepancies between these two values disappeared after arrival in the ICU. There was no incidence of ischemic complications associated with the catheterization of both arteries. Conclusion: The authors suggest that femoral arterial pressure monitoring can be safely performed, even in neonates, and provides more accurate BP values during CPB-on periods, and immediately after weaning from CPB, especially when CPB time was greater than 60 min. Resumo: Objetivo: Diversos relatos alegam que a pressão arterial (PA na artéria radial poderá subestimar a PA precisa em pacientes gravemente doentes. Aqui, avaliamos diferenças na pressão arterial média (PAM entre a artéria radial e femoral durante cirurgia cardíaca pediátrica para determinar a eficácia do

  13. Failure of Stadard Optical Models to Reproduce Neutron Total Cross Section Difference in the W Isotopes

    Energy Technology Data Exchange (ETDEWEB)

    Anderson, J D; Bauer, R W; Dietrich, F S; Grimes, S M; Finlay, R W; Abfalterer, W P; Bateman, F B; Haight, R C; Morgan, G L; Bauge, E; Delaroche, J P; Romain, P

    2001-11-01

    Recently cross section differences among the isotopes{sup 182,184,186}W have been measured as part of a study of total cross sections in the 5-560 MeV energy range. These measurements show oscillations up to 150 mb between 5 and 100 MeV. Spherical and deformed phenomenological optical potentials with typical radial and isospin dependences show very small oscillations, in disagreement with the data. In a simple Ramsauer model, this discrepancy can be traced to a cancellation between radial and isospin effects. Understanding this problem requires a more detailed model that incorporates a realistic description of the neutron and proton density distributions. This has been done with results of Hartree-Fock-Bogolyubov calculations using the Gogny force, together with a microscopic folding model employing a modification of the JLM potential as an effective interaction. This treatment yields a satisfactory interpretation of the observed total cross section differences.

  14. Effect of prenatal exposure to different salt concentration on the third month's weight and blood pressure in wistar rat

    International Nuclear Information System (INIS)

    Fereidoun, H.

    2009-01-01

    In utero alterations in fluid and electrolyte endocrine systems may result in permanent effects on offspring. A low sodium intake during prenatal life jeopardizes growth in young rats, prenatal high-salt diet in Sprague-Dawley rats caused an increase in MAP at postnatal day 30. The objective of this study was to determine the effect of prenatal exposure to different salt concentrations on the third month's weight and blood pressure in Wistar rat. This study was performed at the Department of Physiology, Isfahan University of Medical Science, Isfahan, Iran, over a period from 1998 to 2003. Six groups of rat, 1 male and 5 female in each group were exposed to 0.5, 1, 1.4, 1.6, 1.8 and 2 percent of salt concentrations during pre-pregnancy, pregnancy and lactation period, another test group consumed distilled water and control group used Isfahan tap water, other living conditions for all groups were similar. Exposure to different salt concentrations on the third month's weight and blood pressure was evaluated. Prenatal exposure to 0.5 and 1% salt concentrations gives birth to more alive and healthy infants, and third month's weight increased significantly, but blood pressure was not influenced significantly. Salt concentrations higher than 1% increased the maternal and infant mortality rate and blood pressure significantly, but some concentrations decreased third month's weight significantly. Level of dietary salt during intrauterine development can influence on the number of alive and healthy infants, birth weight, third month' weight and blood pressure significantly. There is no need to introduce a salt restricted diet in prenatal care, a balanced diet in sodium during pregnancy is recommended, high salt diet creates harmful effect. (author)

  15. Cardiopulmonary function and oxygen delivery during total liquid ventilation.

    Science.gov (United States)

    Tsagogiorgas, Charalambos; Alb, Markus; Herrmann, Peter; Quintel, Michael; Meinhardt, Juergen P

    2011-10-01

    Total liquid ventilation (TLV) with perfluorocarbons has shown to improve cardiopulmonary function in the injured and immature lung; however there remains controversy over the normal lung. Hemodynamic effects of TLV in the normal lung currently remain undetermined. This study compared changes in cardiopulmonary and circulatory function caused by either liquid or gas tidal volume ventilation. In a prospective, controlled study, 12 non-injured anesthetized, adult New Zealand rabbits were primarily conventionally gas-ventilated (CGV). After instrumentation for continuous recording of arterial (AP), central venous (CVP), left artrial (LAP), pulmonary arterial pressures (PAP), and cardiac output (CO) animals were randomized into (1) CGV group and (2) TLV group. In the TLV group partial liquid ventilation was initiated with instillation of perfluoroctylbromide (12 ml/kg). After 15 min, TLV was established for 3 hr applying a volume-controlled, pressure-limited, time-cycled ventilation mode using a double-piston configured TLV. Controls (CGV) remained gas-ventilated throughout the experiment. During TLV, heart rate, CO, PAP, MAP, CVP, and LAP as well as derived hemodynamic variables, arterial and mixed venous blood gases, oxygen delivery, PVR, and SVR did not differ significantly compared to CGV. Liquid tidal volumes suitable for long-term TLV in non-injured rabbits do not significantly impair CO, blood pressure, and oxygen dynamics when compared to CGV. Copyright © 2011 Wiley-Liss, Inc.

  16. Develoment of pressure drop calculation modules for a wire-wrapped LMR subassembly

    International Nuclear Information System (INIS)

    Kim, Young Gyun; Lim, Hyun Jin; Kim, Won Seok; Kim, Young Il

    2000-06-01

    Pressure drop calculation modules for a wire-wrapped LMR subassembly was been developed. This report summarizes present information on pressure drop calculation modules for inlet hole, lower part and upper part of a wire-wrapped LMR subassembly which was developed using simple formulas of sudden expansion and sudden contraction. A case calculation study was done using design data of a KALIMER driver fuel subassembly. And the total pressure drop in the driver fuel subassembly, except for the bundle part, was calculated as 0.13 MPa, which is in the reasonable pressure drop range. The developed modules will be integrated in the total subassembly pressure drop calculation code with further improvements

  17. Experimental investigation of MHD pressure losses in a mock-up of a liquid metal blanket

    Science.gov (United States)

    Mistrangelo, C.; Bühler, L.; Brinkmann, H.-J.

    2018-03-01

    Experiments have been performed to investigate the influence of a magnetic field on liquid metal flows in a scaled mock-up of a helium cooled lead lithium (HCLL) blanket. During the experiments pressure differences between points on the mock-up have been recorded for various values of flow rate and magnitude of the imposed magnetic field. The main contributions to the total pressure drop in the test-section have been identified as a function of characteristic flow parameters. For sufficiently strong magnetic fields the non-dimensional pressure losses are practically independent on the flow rate, namely inertia forces become negligible. Previous experiments on MHD flows in a simplified test-section for a HCLL blanket showed that the main contributions to the total pressure drop in a blanket module originate from the flow in the distributing and collecting manifolds. The new experiments confirm that the largest pressure drops occur along manifolds and near the first wall of the blanket module, where the liquid metal passes through small openings in the stiffening plates separating two breeder units. Moreover, the experimental data shows that with the present manifold design the flow does not distribute homogeneously among the 8 stacked boxes that form the breeding zone.

  18. Choice of marker for assessment of RV dysfunction in acute pulmonary embolism : NT-proBNP, pulmonary artery systolic pressure, mean arterial pressure, or blood pressure index.

    Science.gov (United States)

    Ates, H; Ates, I; Kundi, H; Yilmaz, F M

    2017-12-01

    We aimed to examine the value of NT-proBNP, pulmonary artery systolic pressure (PASP), blood pressure index (BPI), and mean arterial pressure (MAP) in the determination of right ventricular dysfunction (RVD) in patients with acute pulmonary embolism (APE). A total of 547 patients diagnosed with APE were included in the study. Demographic characteristics and comorbid conditions of patients were recorded in patient files. For blood pressure measurement, a calibrated digital blood pressure monitor was used at regular intervals. Blood samples were taken from patients at the time of admission for hemogram, biochemical, and hemostasis blood tests. Echocardiography was performed on all patients to detect RVD and evaluate pulmonary artery pressure. PASP (p blood pressure (p blood cell (p AUC ± SE = 0.975 ± 0.006; p < 0.001) was found to be the best predictor of RVD with a higher sensitivity (92.8%) and specificity (100%). We found that BPI had a better diagnostic discrimination for RVD compared with PASP and NT-proBNP.

  19. Antioxidant White Grape Seed Phenolics: Pressurized Liquid Extracts from Different Varieties

    Directory of Open Access Journals (Sweden)

    Carmen Garcia-Jares

    2015-11-01

    Full Text Available Grape seeds represent a high percentage (20% to 26% of the grape marc obtained as a byproduct from white winemaking and keep a vast proportion of grape polyphenols. In this study, seeds obtained from 11 monovarietal white grape marcs cultivated in Northwestern Spain have been analyzed in order to characterize their polyphenolic content and antioxidant activity. Seeds of native (Albariño, Caiño, Godello, Loureiro, Torrontés, and Treixadura and non-native (Chardonnay, Gewurtzträminer, Pinot blanc, Pinot gris, and Riesling grape varieties have been considered. Low weight phenolics have been extracted by means of pressurized liquid extraction (PLE and further analyzed by LC-MS/MS. The results showed that PLE extracts, whatever the grape variety of origin, contained large amounts of polyphenols and high antioxidant activity. Differences in the varietal polyphenolic profiles were found, so a selective exploitation of seeds might be possible.

  20. Antioxidant White Grape Seed Phenolics: Pressurized Liquid Extracts from Different Varieties

    Science.gov (United States)

    Garcia-Jares, Carmen; Vazquez, Alberto; Lamas, Juan P.; Pajaro, Marta; Alvarez-Casas, Marta; Lores, Marta

    2015-01-01

    Grape seeds represent a high percentage (20% to 26%) of the grape marc obtained as a byproduct from white winemaking and keep a vast proportion of grape polyphenols. In this study, seeds obtained from 11 monovarietal white grape marcs cultivated in Northwestern Spain have been analyzed in order to characterize their polyphenolic content and antioxidant activity. Seeds of native (Albariño, Caiño, Godello, Loureiro, Torrontés, and Treixadura) and non-native (Chardonnay, Gewurtzträminer, Pinot blanc, Pinot gris, and Riesling) grape varieties have been considered. Low weight phenolics have been extracted by means of pressurized liquid extraction (PLE) and further analyzed by LC-MS/MS. The results showed that PLE extracts, whatever the grape variety of origin, contained large amounts of polyphenols and high antioxidant activity. Differences in the varietal polyphenolic profiles were found, so a selective exploitation of seeds might be possible. PMID:26783956

  1. Ionic conductivity ageing investigation of 1Ce10ScSZ in different partial pressures of oxygen

    DEFF Research Database (Denmark)

    Omar, Shobit; Belda, Adriana; Escardino, Agustín

    2011-01-01

    The conductivity and its ageing behaviour has been determined for zirconia co-doped with 10 mol% of Sc2O3 and 1 mol% CeO2 in different partial pressures of oxygen at 600 °C. After 3000 h, samples kept in air, in a humidified mixture of H2/N2 and in humidified H2 exhibited loss in the ionic...

  2. Blood Pressure and Its Association with Gender, Body Mass Index, Smoking, and Family History among University Students

    Directory of Open Access Journals (Sweden)

    Hussein H. Alhawari

    2018-01-01

    Full Text Available Hypertension is one of the major risk factors associated with cardiovascular diseases. In this study, we will assess the frequency of hypertension among healthy university students and its association with gender, body mass index, smoking, and family history of both hypertension and cardiovascular diseases. We screened healthy university students ranging from 18 to 26 years of age. For each participant, we performed blood pressure measurements using a previously validated device and obtained demographic data, body mass index (BMI, smoking status, and family history of both hypertension and cardiovascular diseases. Out of the total number of 505 participants included in this study, 35.2% have blood pressure between 130/80 and 139/89, and 13.5% have blood pressure of more than 140/90. We found significant gender differences in both systolic pressure (p = 0.003 with mean difference = 18.08 mmHg (CI: 16.13 to 19.9 and diastolic pressure (p = 0.011 with mean difference = 3.6 mmHg (CI: 2.06 to 5.14, higher in males than in females. Upon comparing the mean difference in both systolic and diastolic blood pressure with BMI, we found significant differences in both systolic (p < 0.001 and diastolic (p = 0.002 blood pressure. We also found that smokers have significantly (p = 0.025 higher systolic blood pressure (mean difference = 4.2 mmHg, CI: 3.2 mmHg to 8.8 mmHg, but no significant difference for diastolic blood pressure (p = 0.386, compared to nonsmokers. First-degree family history of both hypertension and cardiovascular diseases affected systolic but not diastolic blood pressure. Taking into account the adverse short- and long-term effect of hypertension, we recommend adopting an awareness program highlighting the importance of screening blood pressure in young adolescent populations, keeping in mind that both high BMI and smoking are important modifiable factors.

  3. A Study on Anthropometric Measurements, Blood Pressure, Blood Sugar and Food Intakes Among Different Social Status and Ethnicities

    Directory of Open Access Journals (Sweden)

    Jafarirad

    2016-09-01

    Full Text Available Background Metabolic syndrome is a disorder that increases the risk of cardiovascular disease and diabetes. Objectives The aim of the study was to evaluate some risk factors of the metabolic syndrome and food intakes among people who lived in Ahvaz City, Iran. Methods It was a filed study that was conducted on 211 subjects who participated in health exhibition. Socioeconomic status and ethnicity were asked by a general questionnaire. Weight, height, body mass index, waist circumference (WC and WC to hip circumference ratio (WHR were obtained. Blood sugar was measured by a glucometer. Systolic and diastolic blood pressures were obtained and dietary intakes were assessed by a brief instrument. Results There was a significant difference in weight, height, WC, WHR and systolic blood pressure among different jobs. Workers had more intakes of cake and sweets. Arab subjects had more intakes of bread and fishes and Persians more intakes of vegetables. Soda, chocolate and candy were more consumed by Kurd ethnicity. Conclusions Job may be accounted as an important effective socioeconomic factor related to metabolic syndrome risk factors; also different cultures due to different ethnicities may have an influence on lifestyle and dietary intakes.

  4. Pressure effects on nanostructured manganites

    International Nuclear Information System (INIS)

    Acha, C.; Garbarino, G.; Leyva, A.G.

    2007-01-01

    We have measured the pressure sensitivity of magnetic properties on La 5/8-y Pr y Ca 3/8 MnO 3 (y=0.3) nanostructured powders. Samples were synthesized following a microwave assisted denitration process and a final heat treatment at different temperatures to control the grain size of the samples. A span in grain diameters from 40 nm to ∼1000 nm was obtained. Magnetization curves as a function of temperature were measured following different thermomagnetic histories. AC susceptibility as a function of temperature was also measured at different hydrostatic pressures (up to 10 kbar) and for different frequencies. Our results indicate that the nanostructuration plays a role of an internal pressure, producing a structural deformation with similar effects to those obtained under an external hydrostatic pressure

  5. Age-Related Differences in Motor Coordination during Simultaneous Leg Flexion and Finger Extension: Influence of Temporal Pressure

    Science.gov (United States)

    Hussein, Tarek; Yiou, Eric; Larue, Jacques

    2013-01-01

    Although the effect of temporal pressure on spatio-temporal aspects of motor coordination and posture is well established in young adults, there is a clear lack of data on elderly subjects. This work examined the aging-related effects of temporal pressure on movement synchronization and dynamic stability. Sixteen young and eleven elderly subjects performed series of simultaneous rapid leg flexions in an erect posture paired with ipsilateral index-finger extensions, minimizing the difference between heel and finger movement onsets. This task was repeated ten times under two temporal conditions (self-initiated [SI] vs. reaction-time [RT]). Results showed that, first, temporal pressure modified movement synchronization; the finger extension preceded swing heel-off in RT, and inversely in SI. Synchronization error and associated standard deviation were significantly greater in elderly than in young adults in SI only, i.e. in the condition where proprioception is thought to be crucial for temporal coordination. Secondly, both groups developed a significantly shorter mediolateral (ML) anticipatory postural adjustment duration in RT (high temporal pressure) than in SI. In both groups, this shortening was compensated by an increase in the anticipatory peak of centre-of-gravity (CoG) acceleration towards the stance-leg so that ML dynamic stability at foot-off, quantified with the “extrapolated centre-of-mass”, remained unchanged across temporal conditions. This increased CoG acceleration was associated with an increased anticipatory peak of ML centre-of-pressure shift towards the swing-leg in young adults only. This suggested that the ability to accelerate the CoG with the centre-of-pressure shift was degraded in elderly, probably due to weakness in the lower limb muscles. Dynamic stability at foot-off was also degraded in elderly, with a consequent increased risk of ML imbalance and falling. The present study provides new insights into the ability of elderly adults to

  6. Age-related differences in motor coordination during simultaneous leg flexion and finger extension: influence of temporal pressure.

    Directory of Open Access Journals (Sweden)

    Tarek Hussein

    Full Text Available Although the effect of temporal pressure on spatio-temporal aspects of motor coordination and posture is well established in young adults, there is a clear lack of data on elderly subjects. This work examined the aging-related effects of temporal pressure on movement synchronization and dynamic stability. Sixteen young and eleven elderly subjects performed series of simultaneous rapid leg flexions in an erect posture paired with ipsilateral index-finger extensions, minimizing the difference between heel and finger movement onsets. This task was repeated ten times under two temporal conditions (self-initiated [SI] vs. reaction-time [RT]. Results showed that, first, temporal pressure modified movement synchronization; the finger extension preceded swing heel-off in RT, and inversely in SI. Synchronization error and associated standard deviation were significantly greater in elderly than in young adults in SI only, i.e. in the condition where proprioception is thought to be crucial for temporal coordination. Secondly, both groups developed a significantly shorter mediolateral (ML anticipatory postural adjustment duration in RT (high temporal pressure than in SI. In both groups, this shortening was compensated by an increase in the anticipatory peak of centre-of-gravity (CoG acceleration towards the stance-leg so that ML dynamic stability at foot-off, quantified with the "extrapolated centre-of-mass", remained unchanged across temporal conditions. This increased CoG acceleration was associated with an increased anticipatory peak of ML centre-of-pressure shift towards the swing-leg in young adults only. This suggested that the ability to accelerate the CoG with the centre-of-pressure shift was degraded in elderly, probably due to weakness in the lower limb muscles. Dynamic stability at foot-off was also degraded in elderly, with a consequent increased risk of ML imbalance and falling. The present study provides new insights into the ability of

  7. Age-related differences in motor coordination during simultaneous leg flexion and finger extension: influence of temporal pressure.

    Science.gov (United States)

    Hussein, Tarek; Yiou, Eric; Larue, Jacques

    2013-01-01

    Although the effect of temporal pressure on spatio-temporal aspects of motor coordination and posture is well established in young adults, there is a clear lack of data on elderly subjects. This work examined the aging-related effects of temporal pressure on movement synchronization and dynamic stability. Sixteen young and eleven elderly subjects performed series of simultaneous rapid leg flexions in an erect posture paired with ipsilateral index-finger extensions, minimizing the difference between heel and finger movement onsets. This task was repeated ten times under two temporal conditions (self-initiated [SI] vs. reaction-time [RT]). Results showed that, first, temporal pressure modified movement synchronization; the finger extension preceded swing heel-off in RT, and inversely in SI. Synchronization error and associated standard deviation were significantly greater in elderly than in young adults in SI only, i.e. in the condition where proprioception is thought to be crucial for temporal coordination. Secondly, both groups developed a significantly shorter mediolateral (ML) anticipatory postural adjustment duration in RT (high temporal pressure) than in SI. In both groups, this shortening was compensated by an increase in the anticipatory peak of centre-of-gravity (CoG) acceleration towards the stance-leg so that ML dynamic stability at foot-off, quantified with the "extrapolated centre-of-mass", remained unchanged across temporal conditions. This increased CoG acceleration was associated with an increased anticipatory peak of ML centre-of-pressure shift towards the swing-leg in young adults only. This suggested that the ability to accelerate the CoG with the centre-of-pressure shift was degraded in elderly, probably due to weakness in the lower limb muscles. Dynamic stability at foot-off was also degraded in elderly, with a consequent increased risk of ML imbalance and falling. The present study provides new insights into the ability of elderly adults to deal

  8. Solution-diffusion with defects model for pressure-assisted forward osmosis

    KAUST Repository

    Duan, Jintang

    2014-11-01

    An osmosis transport model is presented that combines the standard internal and external concentration polarization equations in the forward osmosis (FO) field with the selective layer transport equations first proposed by Sherwood in 1967. The Sherwood model describes water flux as the sum of a solute-selective, diffusive component driven by the sum of osmotic pressure and hydraulic pressure differences, and a nonselective, convective component driven by hydraulic pressure difference only. This solution-diffusion with defects (SDWD) model and the solution-diffusion (SD) model were compared against data collected using polyamide thin-film-composite (PA-TFC) and integrally-skinned asymmetric cellulose triacetate (CTA) membranes, evaluated in various configurations. When tested with pure water on the porous support side and 1.5. M (π=72.7. bar) sodium chloride solution on the selective layer side, applying 1.25. bar of hydraulic pressure to the porous support side increased water flux by an order of magnitude for PA-TFC membranes, but had negligible effect on CTA membrane flux. These large flux variations can be explained by the SDWD model, but not the SD model. To confirm the existence of defects, a PA-TFC membrane was coated with a uniform, highly water-permeable, nonselective polymer. After coating to block convection through defects, the influence of hydraulic pressure on water flux through this membrane essentially disappeared. Water flux through these defects is low (<1% of total water flux for PA-TFC membranes) and of little consequence in practical FO or reverse osmosis (RO) applications. But in pressure-assisted forward osmosis (PAFO) or pressure-retarded osmosis (PRO), convective transport through defects affects the solute concentration difference across the membrane selective layer, increasing or decreasing water flux through defect-free regions. The presence of defects may explain why membrane power density in PRO is lower than that predicted based on

  9. GDI fuel sprays of light naphtha, PRF95 and gasoline using a piezoelectric injector under different ambient pressures

    KAUST Repository

    Wu, Zengyang; Wang, Libing; Badra, Jihad A.; Roberts, William L.; Fang, Tiegang

    2018-01-01

    This study investigates fuel sprays of light naphtha (LN), primary reference fuel (PRF) and gasoline under different ambient pressures with an outwardly opening piezo gasoline direct injection (GDI) fuel injector. The tested gasoline fuel (regular grade with up to 10% ethanol, E10) was obtained by mixing fuels with AKI (the average of the research octane number (RON) and the motor octane number (MON)) of 87 from three local gas stations. Primary reference fuel (PRF) is commonly used as gasoline surrogate fuel and is blended by iso-octane and n-heptane. PRF95 is the blend of 95% iso-octane and 5% n-heptane by volume. LN fuel was provided by Saudi Aramco Oil Company. Five different ambient pressure conditions varied from 1 bar to 10 bar were tested. The spray was visualized by applying a Mie-scattering technique and a high-speed camera was employed to capture the spray images. The spray structure, spray angle, spray penetration length and spray front fluctuation were analyzed and compared among three fuels. Spray images show that a clear filamentary hollow-cone spray structure is formed for all three fuels at atmospheric conditions, and toroidal recirculation vortexes are observed at the downstream spray edges. A higher ambient pressure leads to a stronger vortex located closer to the injector outlet. Generally speaking, larger spray angles are found under higher ambient pressure conditions for all three fuels. Gasoline fuel always has the largest spray angle for each ambient pressure, while PRF95 has the smallest at most time. For each fuel, the spray front penetration length and spray front penetration velocity decrease with increasing ambient pressure. LN, PRF95 and gasoline show similar penetration length and velocity under the tested conditions. A two-stage spray front fluctuation pattern is observed for all three fuels. Stage one begins from the start of the injection and ends at 450–500 μs after the start of the injection trigger (ASOIT) with a slow

  10. GDI fuel sprays of light naphtha, PRF95 and gasoline using a piezoelectric injector under different ambient pressures

    KAUST Repository

    Wu, Zengyang

    2018-03-20

    This study investigates fuel sprays of light naphtha (LN), primary reference fuel (PRF) and gasoline under different ambient pressures with an outwardly opening piezo gasoline direct injection (GDI) fuel injector. The tested gasoline fuel (regular grade with up to 10% ethanol, E10) was obtained by mixing fuels with AKI (the average of the research octane number (RON) and the motor octane number (MON)) of 87 from three local gas stations. Primary reference fuel (PRF) is commonly used as gasoline surrogate fuel and is blended by iso-octane and n-heptane. PRF95 is the blend of 95% iso-octane and 5% n-heptane by volume. LN fuel was provided by Saudi Aramco Oil Company. Five different ambient pressure conditions varied from 1 bar to 10 bar were tested. The spray was visualized by applying a Mie-scattering technique and a high-speed camera was employed to capture the spray images. The spray structure, spray angle, spray penetration length and spray front fluctuation were analyzed and compared among three fuels. Spray images show that a clear filamentary hollow-cone spray structure is formed for all three fuels at atmospheric conditions, and toroidal recirculation vortexes are observed at the downstream spray edges. A higher ambient pressure leads to a stronger vortex located closer to the injector outlet. Generally speaking, larger spray angles are found under higher ambient pressure conditions for all three fuels. Gasoline fuel always has the largest spray angle for each ambient pressure, while PRF95 has the smallest at most time. For each fuel, the spray front penetration length and spray front penetration velocity decrease with increasing ambient pressure. LN, PRF95 and gasoline show similar penetration length and velocity under the tested conditions. A two-stage spray front fluctuation pattern is observed for all three fuels. Stage one begins from the start of the injection and ends at 450–500 μs after the start of the injection trigger (ASOIT) with a slow

  11. Comparison of ambulatory blood pressure monitoring and office blood pressure measurements in obese children and adolescents.

    Science.gov (United States)

    Renda, Rahime

    2018-04-01

    Obesity in adults has been related to hypertension and abnormal nocturnal dipping of blood pressure, which are associated with poor cardiovascular and renal outcomes. Here, we aimed to resolve the relationship between the degree of obesity, the severity of hypertension and dipping status on ambulatory blood pressure in obese children. A total 72 patients with primary obesity aged 7 to 18 years (mean: 13.48 ± 3.25) were selected. Patients were divided into three groups based on body mass index (BMİ) Z-score. Diagnosis and staging of ambulatory hypertension based on 24-h blood pressure measurements, obtained from ambulatory blood pressure monitoring. Based on our ambulatory blood pressure data, 35 patients (48.6%) had hypertension, 7 (20%) had ambulatory prehypertension, 21 (60%) had hypertension, and 7 patients (20%) had severe ambulatory hypertension. There was a significant relationship between severity of hypertension and the degree of obesity (p lood pressure results and loads were similar between groups. Diastolic and mean arterial blood pressure levels during the night, diastolic blood pressure loads, and heart rate during the day were significantly higher in Group 3 (p lood pressure at night, mean arterial pressure at night, diastolic blood pressure loads and heart rate at day. Increase in BMI Z-score does not a significant impact on daytime blood pressure and nocturnal dipping status.

  12. Body fat and blood pressure: comparison of blood pressure measurements in Chinese children with different body fat levels.

    Science.gov (United States)

    Ma, Jun; Wang, Zhiqiang; Dong, Bin; Song, Yi; Hu, Peijin; Zhang, Bing

    2012-11-14

    Children in China are experiencing a rapid increase in the prevalence of obesity, which is associated with hypertension. To compare the effect of body fat on blood pressure (BP) with that of the normal physical growth, we compared BP levels in Chinese children with different body fat levels. In the present population-based study, 13 972 children in the highest-skinfold-thickness-quartile group were individually matched to 13 972 children in the lowest-skinfold-thickness-quartile group by height and weight. Similarly, 5103 children in the highest-waist-circumference-quartile group were matched to the same number of children in the lowest-waist-circumference-quartile group. The high- and low-fat groups had similar height and weight but the high-fat group had significantly higher skinfold and waist circumference measurements. The differences in systolic BP (SBP) between the high- and low-skinfold-thickness groups were small: 0·01 (95 % CI -0·41, 0·44) mmHg in boys and 0·20 (95 % CI -0·15, 0·54) mmHg in girls. The differences in diastolic BP (DBP) were also small (0·39 and 0·38 mmHg for boys and girls, respectively) but were statistically significant. The differences in both SBP and DBP between the high- and low-waist-circumference groups were small but not statistically significant. For a given body size as measured by height and weight, relative body fat had little impact on BP levels in these children. Fat mass and lean mass may have a similar quantitative impact on BP in healthy-weight children.

  13. Intraocular pressure measurement by three different tonometers in primary congenital glaucoma

    Directory of Open Access Journals (Sweden)

    Athar Zareei

    2015-01-01

    Full Text Available Purpose: To determine the agreement between intraocular pressure (IOP measurements using an automated non-contact tonometer (NCT, Goldmann applanation tonometer (GAT, and the ocular response analyzer (ORA in subjects with primary congenital glaucoma (PCG. Methods: Twenty-nine eyes of 17 PCG patients underwent IOP measurements using NCT, GAT and ORA. Variables obtained by the ORA were corneal-compensated IOP (IOPcc, Goldmann-correlated IOP (IOPg, corneal hysteresis (CH, and corneal resistance factor (CRF. A difference more than 1.5 mmHg for IOP was considered as clinically relevant. Results: Mean age of the patients was 12 years. Mean IOP (±standard deviation, SD was 15.3 ± 2.8 mmHg (GAT, 15.5 ± 6.0 (NCT, 19.2 ± 7.0 (IOPg, and 21.1 ± 7.9 (IOPcc; (P = 0.001. Except for NCT vs. GAT (P = 1.0, the average IOP difference between each pair of measurements was clinically relevant. The 95% limits of agreements were − 10.2 to 10.3 mmHg (NCT vs. GAT, −7.8 to 15.3 (IOPg vs. GAT, and − 8.1 to 19.0 (IOPcc vs. GAT. The differences in IOP measurements increased significantly with higher average IOP values (r = 0.715, P = 0.001, for NCT vs. GAT; r = 0.802, P < 0.001, for IOPg vs. GAT; and r = 0.806, P < 0.001, for IOPcc vs. GAT. CH showed a significant association with differences in IOP measurements only for IOPcc vs. GAT (r = 0.830, P < 0.001. Conclusion: Mean IOP obtained by NCT was not significantly different from that of GAT, but ORA measured IOPs were significantly higher than both other devices.

  14. Structural and optical properties of GaN thin films grown on Al2O3 substrates by MOCVD at different reactor pressures

    International Nuclear Information System (INIS)

    Guillén-Cervantes, A.; Rivera-Álvarez, Z.; López-López, M.; Ponce-Pedraza, A.; Guarneros, C.; Sánchez-Reséndiz, V.M.

    2011-01-01

    GaN thin films grown by MOCVD on (0 0 0 1) Al 2 O 3 substrates at different growth pressures were characterized by field-emission scanning electron microscopy, atomic force microscopy, micro-Raman, and photoluminescence at room temperature. It was found that there is an optimum pressure of 76 Torr at which the structural and optical properties of the GaN samples are superior. On the other hand samples grown at higher pressure exhibited hexagonal surface pits and surface spirals. The results showed that the growth pressure strongly influences the morphology, and significantly affects the structural and optical properties of the GaN epilayers.

  15. Comparative study on two different seal surface structure for reactor pressure vessel sealing behavior

    International Nuclear Information System (INIS)

    Chen Jun; Xiong Guangming; Deng Xiaoyun

    2014-01-01

    The seal surface structure is very important to reactor pressure vessel (RPV) sealing behavior. In this paper, two 3-D RPV sealing analysis finite models have been established with different seal surface structures, in order to study the influence of two structures. The separation of RPV upper and lower flanges, bolt loads and etc. are obtained, which are used to evaluate the sealing behavior of the RPV. Meanwhile, the comparative analysis of safety margin of two seal surface structural had been done, which provides the theoretical basis for RPV seal structure design optimization. (authors)

  16. Clam bioaccumulation of Alkylphenols and Polyciclic aromatic hydrocarbons in the Venice lagoon under different pressures.

    Science.gov (United States)

    Ademollo, N; Patrolecco, L; Matozzo, V; Marin, M G; Valsecchi, S; Polesello, S

    2017-11-15

    Biota-Sediment Accumulation Factors (BSAFs) of nonylphenols (NPs) and polycyclic aromatic hydrocarbons (PAHs) in Ruditapes philippinarum from the Venice Lagoon (Italy) were determined with the aim to verify whether the routine biomonitoring studies are reliable in contaminated sites. Clams and sediments were collected in field campaigns (October 2003 to June 2004) in three sites of the Venice Lagoon. Results showed that Marghera and Campalto sediments were more contaminated by NPs and PAHs than Poveglia. Different trends were observed in the contamination of clams with the highest BSAFs found at Poveglia. BSAF trend appeared to be inversely related to the contaminant pressure on the sites. These results suggest that clam bioaccumulation is not always representative of the chemical pressure on aquatic biota. The direct correlation between sediment and biota concentrations in contaminated sites can be lost as a function of the site-specific conditions such as sediment toxicity and food availability. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. Inter-Arm Blood Pressure Difference in Hospitalized Elderly Patients Is Not Associated With Excess Mortality.

    Science.gov (United States)

    Weiss, Avraham; Grossman, Alon; Beloosesky, Yichayaou; Koren-Morag, Nira; Green, Hefziba; Grossman, Ehud

    2015-10-01

    Inter-arm blood pressure difference (IAD) has been found to be associated with cardiovascular mortality. Its clinical significance and association with mortality in the elderly is not well defined. This study evaluated the association of IAD with mortality in a cohort of hospitalized elderly individuals. Blood pressure (BP) was measured simultaneously in both arms in elderly individuals (older than 65 years) hospitalized in a geriatric ward from October 2012 to July 2014. During the study period, 445 patients, mostly women (54.8%) with a mean age of 85±5 years, were recruited. Systolic and diastolic IAD were >10 mm Hg in 102 (22.9%) and 76 (17.1%) patients, respectively. Patients were followed for an average of 342±201 days. During follow-up, 102 patients (22.9%) died. Mortality was not associated with systolic or diastolic IAD. It is therefore questionable whether BP should be routinely measured in both arms in the elderly. © 2015 Wiley Periodicals, Inc.

  18. Phase behaviour of pseudo-binary systems of pressurized ((propane + L,L-lactide)) at different ethanol to L,L-lactide mole ratios

    International Nuclear Information System (INIS)

    Bender, João P.; Tres, Marcus V.; Corazza, Marcos L.; Ferreira, Sandra R.S.; Oliveira, J. Vladimir

    2014-01-01

    Highlights: • Phase equilibrium data of (propane + L,L-lactide) system at different ethanol to monomer mole ratios. • Static synthetic method from (323 to 353) K and pressures up to 3.3 MPa. • (Vapour + liquid) (VLE) was observed with bubble point (BP) type transitions. • Experimental modelled using the Peng–Robinson (PR) equation with the Wong–Sandler (PR–WS) rule. - Abstract: This work reports phase equilibrium data of pressurized (propane + L,L-lactide) system at different ethanol to monomer mole ratios (9:1; 7:1; 5:1). Phase equilibrium experiments were accomplished in a high-pressure variable-volume view cell employing the static synthetic method. (Vapour + liquid) equilibrium data for the pseudo-binary systems were determined within the temperature range from (323 to 353) K and pressures up to 3.3 MPa. For the systems investigated, (vapour + liquid) equilibrium (VLE) was visually recorded. It was observed that an increase in temperature or in propane concentration led to a pronounced rise in pressure transition values. On the other hand, an increase in the ethanol to L,L-lactide mole ratio led to a reduction in pressure transitions, whereas a reduction in ethanol concentration complicates the achievement of one-phase homogeneous system. Thus, rapid complete miscibility of the system can be controlled by the amount of ethanol added as a co-solvent. The experimental results were modelled using the Peng–Robinson (PR) equation of state with the Wong–Sandler (PR–WS) mixing rule, providing a good representation of the experimental phase transition points

  19. [Efficiency between the different measurement patterns of home blood pressure monitoring in the follow-up of hypertensive patients in primary care].

    Science.gov (United States)

    De León-Robert, Arleen; Hidalgo-García, Isabel; Gascón-Cánovas, Juan; Antón-Botella, José; López-Alegría, Carmen; Campusano Castellanos, Heidi

    2018-03-29

    To identify the most efficient measurement pattern of home blood pressure monitoring (HBPM) for the follow-up of hypertensive patients in primary care. Validation study of a diagnostic test. Primary care team in Murcia, Spain. One hundred and fifty three hypertensive patients younger than 80 years who met the inclusion criteria, who used HBPM and ambulatory blood pressure monitoring. Performing HBPM for 24hours. The HBPM protocol consisted of recording 2 measurements in the morning and 2 in the evening for 7 days. With the records obtained, the different HBPM patterns were established (7, 6, 5, 4, 3 days). The ROC curves were used for the analysis, together with the correlation coefficients and the Bland-Altman plots. The best areas under the curve for the systolic pressure of the different HBPM patterns corresponded to the 4-day pattern: 0.837 (0.77-0.90); and the 3 day one: 0.834 (0.77-0.90). As for diastolic pressure, the 7-day pattern had an area under the curve of 0.889 (0.84-0.94); followed by the 3 and 4 days patterns, which had the same statistical result both: 0.834 (0.83-0.94). There were no significant differences between correlation coefficients for systolic and diastolic blood pressures. The 3-day pattern showed a lower dispersion in the Bland-Altman plots. The 3 days HBPM pattern is proposed for the follow-up of the hypertensive patient, since it does not have an inferior efficiency to the other patterns. Copyright © 2018 The Author. Publicado por Elsevier España, S.L.U. All rights reserved.

  20. Commercial laying hen diets formulated according to different recommendations of total and digestible amino acids

    Directory of Open Access Journals (Sweden)

    EM Casartelli

    2005-09-01

    Full Text Available An experiment was conducted to evaluate different commercial laying hen diets formulated based on recommendations for total and digestible amino acids. One hundred and twenty Lohmann LSL commercial laying hens aged 25 weeks were distributed in a completely randomized experimental design involving five replications of six birds in four treatments. Diet formulation on a total amino acid basis followed the recommendations of NRC (1994 and Rostagno et al. (2000, whereas formulation on digestible amino acids basis was according to Rostagno et al. (2000 and Degussa (1997 recommendations. The experimental period was divided into five periods of fourteen days. Performance parameters (egg production, feed intake, feed conversion, egg mass were evaluated for each period, and on the last two days of each period, three eggs per replication were collected to evaluate egg quality parameters (Haugh unit, egg specific gravity, egg weight, eggshell thickness and percentage. Means were compared by orthogonal contrasts. Results on feed intake, egg production, egg mass, feed conversion and egg specific gravity showed that total amino acid recommendations promoted better bird responses than digestible amino acid recommendations.