WorldWideScience

Sample records for total potential savings

  1. Priority listing of industrial processes by total energy consumption and potential for savings. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Streb, A.J.

    1977-01-01

    A survey of eight of the most energy-intensive segments of the U.S. industry is made to quantify the energy consumed in the principal process units, to identify areas in which significant improvement appear possible, and to rank the process units in terms of total energy consumption and the potential for improvement. Data on the steel, paper, aluminum, textile, cement, and glass industries, petroleum refineries, and olefins and derivative products industries were compiled to help plan the development of new energy sources and to provide targets for energy conservation activities. (MCW)

  2. Estimating the energy saving potential of telecom operators in China

    International Nuclear Information System (INIS)

    Yang, Tian-Jian; Zhang, Yue-Jun; Huang, Jin; Peng, Ruo-Hong

    2013-01-01

    A set of models are employed to estimate the potential of total energy saved of productions and segmented energy saving for telecom operators in China. During the estimation, the total energy saving is divided into that by technology and management, which are derived from technical reform and progress, and management control measures and even marketing respectively, and the estimating methodologies for energy saving potential of each segment are elaborated. Empirical results from China Mobile indicate that, first, the technical advance in communications technology accounts for the largest proportion (70%–80%) of the total energy saved of productions in telecom sector of China. Second, technical reform brings about 20%–30% of the total energy saving. Third, the proportions of energy saving brought by marketing and control measures appear relatively smaller, just less than 3%. Therefore, China's telecom operators should seize the opportunity of the revolution of communications network techniques in recent years to create an advanced network with lower energy consumption

  3. Potential Logistics Cost Savings from Engine Commonality

    National Research Council Canada - National Science Library

    Henderson, Robert L; Higer, Matthew W

    2007-01-01

    The purpose of this MBA Project is to determine potential logistics cost savings the USAF and DoD could have realized through the life of the F-16 fighter aircraft had they required engine commonality...

  4. Potential energy savings and thermal comfort

    DEFF Research Database (Denmark)

    Jensen, Karsten Ingerslev; Rudbeck, Claus Christian; Schultz, Jørgen Munthe

    1996-01-01

    The simulation results on the energy saving potential and influence on indoor thermal comfort by replacement of common windows with aerogel windows as well as commercial low-energy windows are described and analysed.......The simulation results on the energy saving potential and influence on indoor thermal comfort by replacement of common windows with aerogel windows as well as commercial low-energy windows are described and analysed....

  5. Perioperative blood saving measures in total hip and knee arthroplasty

    NARCIS (Netherlands)

    Horstmann, W.G.

    2011-01-01

    This dissertation explores and discusses different aspects of blood loss and blood-saving measures in total hip and knee arthroplasty. Background: Worldwide, approximately 1 million total hip and 1 million total knee prostheses are implanted each year. Total hip arthroplasty and total

  6. Economic Energy Savings Potential in Federal Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Brown, Daryl R.; Dirks, James A.; Hunt, Diane M.

    2000-09-04

    The primary objective of this study was to estimate the current life-cycle cost-effective (i.e., economic) energy savings potential in Federal buildings and the corresponding capital investment required to achieve these savings, with Federal financing. Estimates were developed for major categories of energy efficiency measures such as building envelope, heating system, cooling system, and lighting. The analysis was based on conditions (building stock and characteristics, retrofit technologies, interest rates, energy prices, etc.) existing in the late 1990s. The potential impact of changes to any of these factors in the future was not considered.

  7. Potential cost savings with terrestrial rabies control

    Directory of Open Access Journals (Sweden)

    Cherry Bryan

    2007-04-01

    Full Text Available Abstract Background The cost-benefit of raccoon rabies control strategies such as oral rabies vaccination (ORV are under evaluation. As an initial quantification of the potential cost savings for a control program, the collection of selected rabies cost data was pilot tested for five counties in New York State (NYS in a three-year period. Methods Rabies costs reported to NYS from the study counties were computerized and linked to a human rabies exposure database. Consolidated costs by county and year were averaged and compared. Results Reported rabies-associated costs for all rabies variants totalled $2.1 million, for human rabies postexposure prophylaxes (PEP (90.9%, animal specimen preparation/shipment to laboratory (4.7%, and pet vaccination clinics (4.4%. The proportion that may be attributed to raccoon rabies control was 37% ($784,529. Average costs associated with the raccoon variant varied across counties from $440 to $1,885 per PEP, $14 to $44 per specimen, and $0.33 to $15 per pet vaccinated. Conclusion Rabies costs vary widely by county in New York State, and were associated with human population size and methods used by counties to estimate costs. Rabies cost variability must be considered in developing estimates of possible ORV-related cost savings. Costs of PEPs and specimen preparation/shipments, as well as the costs of pet vaccination provided by this study may be valuable for development of more realistic scenarios in economic modelling of ORV costs versus benefits.

  8. Energy Savings Potential of Radiative Cooling Technologies

    Energy Technology Data Exchange (ETDEWEB)

    Fernandez, Nicholas [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Wang, Weimin [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Alvine, Kyle J. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Katipamula, Srinivas [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2015-11-30

    Pacific Northwest National Laboratory (PNNL), with funding from the U.S. Department of Energy’s (DOE’s) Building Technologies Program (BTP), conducted a study to estimate, through simulation, the potential cooling energy savings that could be achieved through novel approaches to capturing free radiative cooling in buildings, particularly photonic ‘selective emittance’ materials. This report documents the results of that study.

  9. Energy saving potential in existing industrial compressors

    International Nuclear Information System (INIS)

    Vittorini, Diego; Cipollone, Roberto

    2016-01-01

    The Compressed Air Sector accounts for a mean 10% worldwide electricity consumption, which ensures about its importance, when energy saving and CO_2 emissions reduction are in question. Since the compressors alone account for 15% overall industry electricity consumption, it appears vital to pay attention to machine performances. The paper presents an overview of present compressor technology and focuses on saving directions for screw and sliding vanes machines, according to data provided by the Compressed Air and Gas Institute and PNEUROP. Data were processed to obtain consistency with fixed reference pressures and organized as a function of main operating parameters. Each sub-term, contributing to the overall efficiency (adiabatic, volumetric, mechanical, electric, organic), was considered separately: the analysis showed that the thermodynamic improvement during compression achievable by splitting the compression in two stages, with a lower compression ratio, opens the way to significantly reduce the energy specific consumption. - Highlights: • Compressors technology overview in industrial compressed air systems. • Market compressors efficiency baseline definition. • Energy breakdown and evaluation of main efficiency terms. • Assessment of air cooling-related energy saving potential. • Energy specific consumption reduction through dual stage compression.

  10. Natural gas decompression energy recovery: Energy savings potential in Italy

    International Nuclear Information System (INIS)

    Piatti, A.; Piemonte, C.; Rampini, E.; Vatrano, F.; Techint SpA, Milan; ENEA, Rome

    1992-01-01

    This paper surveyed the natural gas distribution systems employed in the Italian civil, industrial and thermoelectric sectors to identify those installations which can make use of gas decompression energy recovery systems (consisting of turbo-expanders or alternative expanders) to economically generate electric power. Estimates were then made of the total amount of potential energy savings. The study considered as eligible for energy savings interventions only those plants with a greater than 5,000 standard cubic meter per hour plant capacity. It was evaluated that, with suitable decompression equipment installed at 50 key installations (33 civil, 15 industrial), about 200 GWh of power could be produced annually, representing potential savings of about 22,000 petroleum equivalent tonnes of energy. A comparative analysis was done on three investment alternatives involving inputs of varying amounts of Government financial assistance

  11. User behaviour impact on energy savings potential

    DEFF Research Database (Denmark)

    Rose, Jørgen

    2014-01-01

    and the residents' behaviour and if these defaults do not reflect actual circumstances, it can result in non-realisation of expected energy savings. Furthermore, a risk also exists that residents' behaviour change after the energy upgrading, e.g. to obtain improved comfort than what was possible before......, 3) Domestic hot water consumption and 4) Air change rate. Based on the analysis, a methodology is established that can be used to make more realistic and accurate predictions of expected energy savings associated with energy upgrading taking into account user behaviour....... the upgrading and this could lead to further discrepancies between the calculated and the actual energy savings. This paper presents an analysis on how residents’ behaviour and the use of standard assumptions may influence expected energy savings. The analysis is performed on two typical single-family houses...

  12. Energy Savings Potential and Research & Development Opportunities for Commercial Refrigeration

    Energy Technology Data Exchange (ETDEWEB)

    none,

    2009-09-01

    This study documents the energy consumption of commercial refrigeration equipment (CRE) in the U.S. and evaluated the energy savings potential of various technologies and energy efficiency measures that could be applied to such equipment. The study provided an overview of CRE applications, assessed the energy-savings potential of CRE in the U.S., outline key barriers to adoption of energy-savings technologies, and recommended opportunities for advanced energy saving technology research. The study was modeled after an earlier 1996 report by Arthur D. Little, Inc., and updated key information, examined more equipment types, and outlined long-term research and development opportunities.

  13. Potential energy savings from cool roofs in Spain and Andalusia

    International Nuclear Information System (INIS)

    Boixo, Sergio; Diaz-Vicente, Marian; Colmenar, Antonio; Castro, Manuel Alonso

    2012-01-01

    Cool roofs are an inexpensive method to save energy and to improve the comfort level in buildings in mild and hot climates. A high scale implementation of cool roofs in Andalusia, in the south of Spain, could potentially save 295,000 kWh per year, considering only residential buildings with flat roofs using electrical heating. At the current energy prices, consumers can save 59 million euros annually in electricity costs and the emission of 136,000 metric tons of CO 2 can be directly avoided every year from the production of that electricity. If radiative forcings are considered, Andalucía can potentially offset between 9.44 and 12 Mt of CO 2 . All the provinces in the rest of Spain are also studied in this paper. The biggest savings are achieved in Gran Canaria (48%), Tenerife (48%), Cádiz (36%), Murcia (33%), Huelva (30%), Málaga (29%), Almería (29%) and Sevilla (28%), where savings are greater than 2 euros per square meter of flat roof for old buildings with dark roofs. For the biggest cities the range of savings obtained are: between 7.4% and 11% in Madrid, between 12% and 18% in Barcelona and between 14% and 20% in Valencia. -- Highlights: ► We estimate potential savings in energy, CO 2 , and money for cool roofs in Spain (residential sector with flat roofs). ► Average savings are of around one euro per square meter in the biggest cities. ► Potential savings are of more than 2 €/m 2 in the hottest cities. ► In Andalusia the potential savings are 300 MWh, 60 millions euro and 136,000 tons of CO 2 per year. ► With forcings, the CO 2 equivalence of cool roofs in Andalusia is between 9 and 12 Mt.

  14. Data Network Equipment Energy Use and Savings Potential in Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Lanzisera, Steven; Nordman, Bruce; Brown, Richard E.

    2010-06-09

    Network connectivity has become nearly ubiquitous, and the energy use of the equipment required for this connectivity is growing. Network equipment consists of devices that primarily switch and route Internet Protocol (IP) packets from a source to a destination, and this category specifically excludes edge devices like PCs, servers and other sources and sinks of IP traffic. This paper presents the results of a study of network equipment energy use and includes case studies of networks in a campus, a medium commercial building, and a typical home. The total energy use of network equipment is the product of the stock of equipment in use, the power of each device, and their usage patterns. This information was gathered from market research reports, broadband market penetration studies, field metering, and interviews with network administrators and service providers. We estimate that network equipment in the USA used 18 TWh, or about 1percent of building electricity, in 2008 and that consumption is expected to grow at roughly 6percent per year to 23 TWh in 2012; world usage in 2008 was 51 TWh. This study shows that office building network switches and residential equipment are the two largest categories of energy use consuming 40percent and 30percent of the total respectively. We estimate potential energy savings for different scenarios using forecasts of equipment stock and energy use, and savings estimates range from 20percent to 50percent based on full market penetration of efficient technologies.

  15. Energy savings potential from improved building controls for the US commercial building sector

    Energy Technology Data Exchange (ETDEWEB)

    Fernandez, Nick; Katipamula, Srinivas; Wang, Weimin; Xie, Yulong; Zhao, Mingjie

    2017-09-27

    The U.S. Department of Energy’s (DOE’s) Building Technologies Office (BTO) sponsored a study to determine the potential national savings achievable in the commercial building sector through widespread deployment of best practice controls, elimination of system and component faults, and use of better sensing. Detailed characterization of potential savings was one source of input to set research, development, and deployment (RD&D) goals in the field of building sensors and controls. DOE’s building energy simulation software, EnergyPlus, was employed to estimate the potential savings from 34 measures in 9 building types and across 16 climates representing almost 57% of commercial building sector energy consumption. In addition to estimating savings from individual measures, three packages of measures were created to estimate savings from the packages. These packages represented an 1) efficient building, 2) typical building, and 3) inefficient building. To scale the results from individual measures or a package to the national scale, building weights by building type and climate locations from the Energy Information Administration’s 2012 Commercial Building Energy Consumption Survey (CBECS) were used. The results showed significant potential for energy savings across all building types and climates. The total site potential savings from individual measures by building type and climate location ranged between 0% and 25%. The total site potential savings by building type aggregated across all climates (using the CBECS building weights) for each measure varied between 0% and 16%. The total site potential savings aggregated across all building types and climates for each measure varied between 0% and 11%. Some individual measures had negative savings because correcting underlying operational problems (e.g., inadequate ventilation) resulted in increased energy consumption. When combined into packages, the overall national savings potential is estimated to be 29

  16. Defining The Energy Saving Potential of Architectural Design

    DEFF Research Database (Denmark)

    Naboni, Emanuele; Malcangi, Antonio; Zhang, Yi

    2015-01-01

    Designers, in response to codes or voluntary " green building " programs, are increasingly concerned with building energy demand reduction, but they are not fully aware of the energy saving potential of architectural design. According to literature, building form, construction and material choices...... on sustainable design: " Design With Climate " by Olgyay (1963), which discussed strategies for climate-adapted architecture, and Lechner´s " Heating, Cooling and Lighting " (1991), on how to reduce building energy needs by as much as 60 – 80 percent with proper architectural design decisions. Both books used...... behaviour. The research shows the best solution for each of the climates and compares them with Olgyay´s findings. Finally, for each climate the energy saving potential is defined and then compared to Lechner's conclusions. Defining The Energy Saving Potential of Architectural Design (PDF Download Available...

  17. Savings potential of ENERGY STAR (registered trademark) voluntary labeling programs

    International Nuclear Information System (INIS)

    Webber, Carrie A.; Brown, Richard E.

    1998-01-01

    In 1993 the U.S. Environmental Protection Agency (EPA) introduced ENERGY STAR (registered trademark), a voluntary labeling program designed to identify and promote energy-efficient products. Since then EPA, now in partnership with the U.S. Department of Energy (DOE), has introduced programs for more than twenty products, spanning office equipment, residential heating and cooling equipment, new homes, commercial and residential lighting, home electronics, and major appliances. We present potential energy, dollar and carbon savings forecasts for these programs for the period 1998 to 2010. Our target market penetration case represents our best estimate of future ENERGY STAR savings. It is based on realistic market penetration goals for each of the products. We also provide results under the assumption of 100% market penetration; that is, we assume that all purchasers buy ENERGY STAR-compliant products instead of standard efficiency products throughout the analysis period. Finally, we assess the sensitivity of our target penetration case forecasts to greater or lesser marketing success by EPA and DOE, lower-than-expected future energy prices, and higher or lower rates of carbon emission by electricity generators. The potential savings of ENERGY STAR are substantial. If all purchasers chose Energy Star-compliant products instead of standard efficiency products over the next 15 years, they would save more than$100 billion on their energy bills during those 15 years. (Bill savings are in 1995 dollars, discounted at a 4% real discount rate.)

  18. Estimation on oil demand and oil saving potential of China's road transport sector

    International Nuclear Information System (INIS)

    Lin, Boqiang; Xie, Chunping

    2013-01-01

    China is currently in the stage of industrialization and urbanization, which is characterized by rigid energy demand and rapid growth of energy consumption. Therefore, energy conservation will become a major strategy for China in a transition to low-carbon economy. China's transport industry is of high energy consumption. In 2010, oil consumption in transport industry takes up 38.2% of the country's total oil demand, of which 23.6% is taken up by road transport sector. As a result, oil saving in China's road transport sector is vital to the whole nation. The co-integration method is developed to find a long-run relationship between oil consumption and affecting factors such as GDP, road condition, labor productivity and oil price, to estimate oil demand and to predict future oil saving potential in China's transport sector under different oil-saving scenarios. Monte Carlo simulation is further used for risk analysis. Results show that under BAU condition, oil demand of China's road transport sector will reach 278.5 million ton of oil equivalents (MTOE) in 2020. Oil saving potential will be 86 MTOE and 131 MTOE under moderate oil-saving scenario and advanced oil-saving scenario, respectively. This paper provides a reference to establishing oil saving policy for China's road transport sector. - Highlights: • We adopt the co-integration model to estimate oil demand and oil saving potential of China's road transport sector. • Monte Carlo simulation is further used for risk analysis. • GDP, ratio of classified highway, labor productivity and oil price are main factors affecting oil consumption. • Scenario analysis approach is applied to calculate oil saving potential under different energy saving scenarios. • Future policy for oil conservation in China's road transport sector is suggested

  19. Energy savings potential from energy-conserving irrigation systems

    Energy Technology Data Exchange (ETDEWEB)

    Wilfert, G.L.; Patton, W.P.; Harrer, B.J.; Clark, M.A.

    1982-11-01

    This report systematically compares, within a consistent framework, the technical and economic characteristics of energy-conserving irrigation systems with those of conventional irrigation systems and to determine total energy savings. Levelized annual costs of owning and operating both energy-conserving and conventional irrigation systems have been developed and compared for all 17 states to account for the differences in energy costs and irrigation conditions in each state. Market penetration of energy-conserving systems is assessed for those systems having lower levelized annual costs than conventional systems performing the same function. Annual energy savings were computed by matching the energy savings per system with an assumed maximum market penetration of 100 percent in those markets where the levelized annual costs of energy-conserving systems are lower than the levelized annual costs of conventional systems.

  20. Potential Cost Savings Ideas for FAA and Users

    Science.gov (United States)

    1997-06-04

    The intent of this paper is to catalogue potential cost-savings ideas which : impact both the FAA and the aviation community. These ideas have come from : various sources including MITRE, Coopers & Lybrand (C&L), FAA studies, General : Accounting Off...

  1. The total lifetime health cost savings of smoking cessation to society

    DEFF Research Database (Denmark)

    Rasmussen, Gitte Susanne; Prescott, Eva; Sørensen, Thorkild I A

    2005-01-01

    Smoking cessation has major immediate and long-term health benefits. However, ex-smokers' total lifetime health costs and continuing smokers' costs remain uncompared, and hence the economic savings of smoking cessation to society have not been determined.......Smoking cessation has major immediate and long-term health benefits. However, ex-smokers' total lifetime health costs and continuing smokers' costs remain uncompared, and hence the economic savings of smoking cessation to society have not been determined....

  2. Energy Saving Potential by Utilizing Natural Ventilation under Warm Conditions

    DEFF Research Database (Denmark)

    Oropeza-Perez, Ivan; Østergaard, Poul Alberg

    2014-01-01

    The objective of this article is to show the potential of natural ventilation as a passive cooling method within the residential sector of countries which are located in warm conditions using Mexico as a case study. The method is proposed as performing, with a simplified ventilation model, thermal......–airflow simulations of 27 common cases of dwellings (considered as one thermal zone) based on the combination of specific features of the building design, occupancy and climate conditions. The energy saving potential is assessed then by the use of a new assessment method suitable for large-scale scenarios using...... the actual number of air-conditioned dwellings distributed among the 27 cases. Thereby, the energy saving is presented as the difference in the cooling demand of the dwelling during one year without and with natural ventilation, respectively. Results indicate that for hot-dry conditions, buildings with high...

  3. Potential opportunities for energy savings in a Jordanian poultry company

    International Nuclear Information System (INIS)

    AlQdah, K.

    2010-01-01

    Rising concern about energy resource availability and energy prices in Jordan, cost of energy has become an issue that cannot be ignored in Jordan's industrial sector. In this study, energy auditing in a meat production factory related to poultry company was carried out. Based on the collected data and the conservation laws of energy, the performance of steam boilers, domestic hot water boilers, compressors, refrigeration systems, chillers, pumps, daily consumption of diesel and water were reviewed. The percentage of energy consumed by the refrigeration units, with respect to the total energy consumed, has been estimated. The results demonstrated a normal operation with thermal efficiency of 80.66% for the steam boiler, ability to save 18818.99 JD by installing economizer with payback period of 0.637 year and a 12.3% reduction of the energy cost achieved by reducing the blow down rate. The rate of diesel consumption was reduced by 12.87% over the last period of the study as a result of the recommendations that have been submitted to the technicians and professionals. The sum of 22223.77 JD can be saved by using heavy fuel oil instead of diesel oil. Moreover, this study demonstrated that energy saving can be considered as an ideal choice to increase profit and promote competition within the poultry industry if the company adopts all the proposals and recommendations that have been offered by this study.

  4. Assessing the cost saving potential of shared product architectures

    DEFF Research Database (Denmark)

    Mortensen, Niels Henrik; Hansen, Christian Lindschou; Løkkegaard, Martin

    2016-01-01

    company. Experiences from the case company show it is possible to reduce the number of architectures with 60% which leads to significant reduction in direct material and labor costs. This can be achieved without compromising the market offerings of products. Experiences from the case study indicate cost......This article presents a method for calculating cost savings of shared architectures in industrial companies called Architecture Mapping and Evaluation. The main contribution is an operational method to evaluate the cost potential and evaluate the number of product architectures in an industrial...

  5. Estimating the potential for electricity savings in households

    International Nuclear Information System (INIS)

    Boogen, Nina

    2017-01-01

    Improving efficiency in the use of energy is an important goal for many nations since end-use energy efficiency can help to reduce CO_2 emissions. Furthermore, since the residential sector in industrialised countries requires around one third of the end-use electricity, it is important for policy makers to estimate the scope for electricity saving in households to reduce electricity consumption by using appropriate steering mechanisms. We estimate the level of technical efficiency in the use of electricity using data from a Swiss household survey. We find an average inefficiency in electricity use by Swiss households of around 20 to 25%. Bottom-up economic-engineering models estimate the potential in Switzerland to be around 15%. In this paper we use a sub-vector input distance frontier function based on economic foundations. Our estimates lie at the upper end of the electricity saving potential estimated by the afore-mentioned economic-engineering approach. - Highlights: • We estimate the level of efficiency in the use of electricity by Swiss households. • We apply a non-radial input distance function and stochastic frontier methods. • We use data from two waves of a Swiss household survey conducted in 2005 and 2011. • We find an inefficiency in the use of electricity of around 20–25%.

  6. Understanding usage patterns of electric kettle and energy saving potential

    International Nuclear Information System (INIS)

    Murray, D.M.; Liao, J.; Stankovic, L.; Stankovic, V.

    2016-01-01

    Highlights: • Time-of-use analysis to motivate kettle usage and consumption prediction. • Identification of households whose kettle usage and consumption is outside the norm. • Mathematical model to estimate water volume from consumed power measurements only. • Quantification of energy savings if a household uses its kettle more efficiently. • Kettle usage and demand prediction using an Adaptive Neuro Fuzzy Inference System. - Abstract: The availability of smart metering and smart appliances enables detecting and characterising appliance use in a household, quantifying energy savings through efficient appliance use and predicting appliance-specific demand from load measurements is possible. With growing electric kettle ownership and usage, lack of any efficiency labelling guidelines for the kettle, slow technological progress in improving kettle efficiency relative to other domestic appliances, and current consumer attitudes, urgent investigation into consumer kettle usage patterns is warranted. From an efficiency point of view, little can be done about the kettle, which is more efficient than other methods of heating water such as the stove top kettle. However, since a majority households use the kettle inefficiently by overfilling, in order to meet energy targets, it is imperative to quantify inefficient usage and predict demand. For the purposes of scalability, we propose tools that depend only on load measurement data for quantifying and visualising kettle usage and energy consumption, assessing energy wastage through overfilling via our proposed electric kettle model, and predicting kettle-specific demand, from which we can estimate potential energy savings in a household and across a housing stock. This is demonstrated using data from a longitudinal study across a sample of 14 UK households for a two-year period.

  7. Determining the Cost-Savings Threshold and Alignment Accuracy of Patient-Specific Instrumentation in Total Ankle Replacements.

    Science.gov (United States)

    Hamid, Kamran S; Matson, Andrew P; Nwachukwu, Benedict U; Scott, Daniel J; Mather, Richard C; DeOrio, James K

    2017-01-01

    Traditional intraoperative referencing for total ankle replacements (TARs) involves multiple steps and fluoroscopic guidance to determine mechanical alignment. Recent adoption of patient-specific instrumentation (PSI) allows for referencing to be determined preoperatively, resulting in less steps and potentially decreased operative time. We hypothesized that usage of PSI would result in decreased operating room time that would offset the additional cost of PSI compared with standard referencing (SR). In addition, we aimed to compare postoperative radiographic alignment between PSI and SR. Between August 2014 and September 2015, 87 patients undergoing TAR were enrolled in a prospectively collected TAR database. Patients were divided into cohorts based on PSI vs SR, and operative times were reviewed. Radiographic alignment parameters were retrospectively measured at 6 weeks postoperatively. Time-driven activity-based costing (TDABC) was used to derive direct costs. Cost vs operative time-savings were examined via 2-way sensitivity analysis to determine cost-saving thresholds for PSI applicable to a range of institution types. Cost-saving thresholds defined the price of PSI below which PSI would be cost-saving. A total of 35 PSI and 52 SR cases were evaluated with no significant differences identified in patient characteristics. Operative time from incision to completion of casting in cases without adjunct procedures was 127 minutes with PSI and 161 minutes with SR ( P cost-savings threshold range at our institution of $863 below which PSI pricing would provide net cost-savings. Two-way sensitivity analysis generated a globally applicable cost-savings threshold model based on institution-specific costs and surgeon-specific time-savings. This study demonstrated equivalent postoperative TAR alignment with PSI and SR referencing systems but with a significant decrease in operative time with PSI. Based on TDABC and associated sensitivity analysis, a cost-savings threshold

  8. The potential and need for energy saving in standard family detached and semi-detached wooden houses in arctic Greenland

    DEFF Research Database (Denmark)

    Bjarløv, Søren Peter; Vladyková, Petra

    2011-01-01

    The paper gives an account of the potential and need for energy saving in standard family detached and semi-detached wooden houses in Greenland. It is based on studies of house construction compared with Building Regulation requirements and the spread of buildings over time. In the climatic...... conditions of Greenland, there is considerable potential for energy saving in houses due to their construction, shape and condition. To estimate the total potential for energy saving and thus reducing CO2 emissions, we carried out a detailed investigation of three typical standard semi-detached family houses...

  9. Advertising energy saving programs: The potential environmental cost of emphasizing monetary savings.

    Science.gov (United States)

    Schwartz, Daniel; Bruine de Bruin, Wändi; Fischhoff, Baruch; Lave, Lester

    2015-06-01

    Many consumers have monetary or environmental motivations for saving energy. Indeed, saving energy produces both monetary benefits, by reducing energy bills, and environmental benefits, by reducing carbon footprints. We examined how consumers' willingness and reasons to enroll in energy-savings programs are affected by whether advertisements emphasize monetary benefits, environmental benefits, or both. From a normative perspective, having 2 noteworthy kinds of benefit should not decrease a program's attractiveness. In contrast, psychological research suggests that adding external incentives to an intrinsically motivating task may backfire. To date, however, it remains unclear whether this is the case when both extrinsic and intrinsic motivations are inherent to the task, as with energy savings, and whether removing explicit mention of extrinsic motivation will reduce its importance. We found that emphasizing a program's monetary benefits reduced participants' willingness to enroll. In addition, participants' explanations about enrollment revealed less attention to environmental concerns when programs emphasized monetary savings, even when environmental savings were also emphasized. We found equal attention to monetary motivations in all conditions, revealing an asymmetric attention to monetary and environmental motives. These results also provide practical guidance regarding the positioning of energy-saving programs: emphasize intrinsic benefits; the extrinsic ones may speak for themselves. (c) 2015 APA, all rights reserved).

  10. Financial Impact of Cancer Drug Wastage and Potential Cost Savings From Mitigation Strategies.

    Science.gov (United States)

    Leung, Caitlyn Y W; Cheung, Matthew C; Charbonneau, Lauren F; Prica, Anca; Ng, Pamela; Chan, Kelvin K W

    2017-07-01

    Cancer drug wastage occurs when a parenteral drug within a fixed vial is not administered fully to a patient. This study investigated the extent of drug wastage, the financial impact on the hospital budget, and the cost savings associated with current mitigation strategies. We conducted a cross-sectional study in three University of Toronto-affiliated hospitals of various sizes. We recorded the actual amount of drug wasted over a 2-week period while using current mitigation strategies. Single-dose vial cancer drugs with the highest wastage potentials were identified (14 drugs). To calculate the hypothetical drug wastage with no mitigation strategies, we determined how many vials of drugs would be needed to fill a single prescription. The total drug costs over the 2 weeks ranged from $50,257 to $716,983 in the three institutions. With existing mitigation strategies, the actual drug wastage over the 2 weeks ranged from $928 to $5,472, which was approximately 1% to 2% of the total drug costs. In the hypothetical model with no mitigation strategies implemented, the projected drug cost wastage would have been $11,232 to $149,131, which accounted for 16% to 18% of the total drug costs. As a result, the potential annual savings while using current mitigation strategies range from 15% to 17%. The financial impact of drug wastage is substantial. Mitigation strategies lead to substantial cost savings, with the opportunity to reinvest those savings. More research is needed to determine the appropriate methods to minimize risk to patients while using the cost-saving mitigation strategies.

  11. Potential energy savings and CO2 emissions reduction of China's cement industry

    International Nuclear Information System (INIS)

    Ke, Jing; Zheng, Nina; Fridley, David; Price, Lynn; Zhou, Nan

    2012-01-01

    This study analyzes current energy and carbon dioxide (CO 2 ) emission trends in China's cement industry as the basis for modeling different levels of cement production and rates of efficiency improvement and carbon reduction in 2011–2030. Three cement output projections are developed based on analyses of historical production and physical and macroeconomic drivers. For each of these three production projections, energy savings and CO 2 emission reduction potentials are estimated in a best practice scenario and two continuous improvement scenarios relative to a frozen scenario. The results reveal the potential for cumulative final energy savings of 27.1 to 37.5 exajoules and energy-related direct emission reductions of 3.2 to 4.4 gigatonnes in 2011–2030 under the best practice scenarios. The continuous improvement scenarios produce cumulative final energy savings of 6.0 to 18.9 exajoules and reduce CO 2 emissions by 1.0 to 2.4 gigatonnes. This analysis highlights that increasing energy efficiency is the most important policy measure for reducing the cement industry's energy and emissions intensity, given the current state of the industry and the unlikelihood of significant carbon capture and storage before 2030. In addition, policies to reduce total cement production offer the most direct way of reducing total energy consumption and CO 2 emissions. - Highlights: ► This study models output and efficiency improvements in Chinese cement industry from 2011–2030. ► Energy savings and CO 2 emission reductions estimated for 3 scenarios relative to frozen scenario. ► Results reveal cumulative final energy savings potential of 27.1–37.5 EJ and 3.2–4.4 Gt CO 2 reductions. ► Increasing efficiency is the most important policy for reducing cement energy and emissions intensity.

  12. Energy saving potential of natural ventilation in China: The impact of ambient air pollution

    International Nuclear Information System (INIS)

    Tong, Zheming; Chen, Yujiao; Malkawi, Ali; Liu, Zhu; Freeman, Richard B.

    2016-01-01

    Highlights: • Natural ventilation potential is affected largely by ambient air pollution in China. • NV hours of 76 Chinese cities based on weather and ambient air quality are estimated. • Cooling energy savings and carbon reductions of 35 major Chinese cities are estimated. • 8–78% of the cooling energy usage can be potentially reduced by NV. • Our findings provide guidelines to improve energy policies in China. - Abstract: Natural ventilation (NV) is a key sustainable solution for reducing the energy use in buildings, improving thermal comfort, and maintaining a healthy indoor environment. However, the energy savings and environmental benefits are affected greatly by ambient air pollution in China. Here we estimate the NV potential of all major Chinese cities based on weather, ambient air quality, building configuration, and newly constructed square footage of office buildings in the year of 2015. In general, little NV potential is observed in northern China during the winter and southern China during the summer. Kunming located in the Southwest China is the most weather-favorable city for natural ventilation, and reveals almost no loss due to air pollution. Building Energy Simulation (BES) is conducted to estimate the energy savings of natural ventilation in which ambient air pollution and total square footage at each city must be taken into account. Beijing, the capital city, displays limited per-square-meter saving potential due to the unfavorable weather and air quality for natural ventilation, but its largest total square footage of office buildings makes it become the city with the greatest energy saving opportunity in China. Our analysis shows that the aggregated energy savings potential of office buildings at 35 major Chinese cities is 112 GWh in 2015, even after allowing for a 43 GWh loss due to China’s serious air pollution issue especially in North China. 8–78% of the cooling energy consumption can be potentially reduced by natural

  13. Bandwidth Study on Energy Use and Potential Energy Savings Opportunities in U.S. Petroleum Refining

    Energy Technology Data Exchange (ETDEWEB)

    Sabine Brueske, Caroline Kramer, Aaron Fisher

    2015-06-01

    Energy bandwidth studies of U.S. manufacturing sectors can serve as foundational references in framing the range (or bandwidth) of potential energy savings opportunities. This bandwidth study examines energy consumption and potential energy savings opportunities in U.S. petroleum refining. The study relies on multiple sources to estimate the energy used in nine individual process areas, representing 68% of sector-wide energy consumption. Energy savings opportunities for individual processes are based on technologies currently in use or under development; these potential savings are then extrapolated to estimate sector-wide energy savings opportunity.

  14. Bandwidth Study on Energy Use and Potential Energy Saving Opportunities in U.S. Chemical Manufacturing

    Energy Technology Data Exchange (ETDEWEB)

    Sabine Brueske, Caroline Kramer, Aaron Fisher

    2015-06-01

    Energy bandwidth studies of U.S. manufacturing sectors can serve as foundational references in framing the range (or bandwidth) of potential energy savings opportunities. This bandwidth study examines energy consumption and potential energy savings opportunities in U.S. chemical manufacturing. The study relies on multiple sources to estimate the energy used in the production of 74 individual chemicals, representing 57% of sector-wide energy consumption. Energy savings opportunities for individual chemicals and for 15 subsectors of chemicals manufacturing are based on technologies currently in use or under development; these potential savings are then extrapolated to estimate sector-wide energy savings opportunity.

  15. The likely market potential for electricity saving ASD devices

    International Nuclear Information System (INIS)

    Sparow, F.T.; McKenzie, L.

    1993-01-01

    Many utility demand-side management (DSM) programs encourage the adoption of adjustable speed drives (ASD) in the industrial and commercial sectors, since such devices save KW and KWh. The term open-quotes adjustable speed drives close-quote is used to refer to any device which allows the speed of the motor to be adjusted to better match process requirements. Thus, motor input control devices, such as electronic adjustable speed drives for AC motors (i.e., adjustable frequency drives (AFD)), voltage controlled DC motors, and the use of floating pressure setpoint controls, or other devices which better control on/off compressor operation, would be considered ASD devices. Also included would be motor technologies, such as multi-speed windings, etc., which allow the synchronous speed of the motor to be altered. Not included in this definition would be mechanical systems such as gear boxes, friction disks, etc., which maintain motor speed, but alter the drive r.p.m. to the equipment. The importance of the distinction is that ASDs, as defined above, have the potential to substantially reduce KW and KWh consumption if the equipment duty cycle is varying, while mechanical drive r.p.m. varying devices don't

  16. Textiles industry: Potential saving of 30%, from improving operation management

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Y.S. [Korea Energy Management Corporation, Songnam (Korea, Republic of)

    1998-04-01

    In order to pass over the age of IMF wisely, we should remove all swollen bubbles of the past boldly, design life that is within one`s means, and realize saving and austerity in daily life. As a part of these countermeasures, several plans are needed for energy saving, and Korea Energy Management Corp. has been continuously carrying out energy management diagnosis targeting enterprises that consume energy. This study tries to provide a little help to the business by introducing attentive matters needed in advising energy technology as well as the diagnosis case of energy and analyzing the current condition of advising energy saving technology.

  17. Incorrect storage of medicines and potential for cost savings

    DEFF Research Database (Denmark)

    Colberg, Lene; Schmidt-Petersen, Lone; Hansen, Merete Kock

    2017-01-01

    continue to be used, possibly with a shortened expiry date. Thus, by examining all cases of incorrect storage, the value of drugs that pharmacists advised could be used despite a broken cold chain, could be estimated. Results The Medicine Information Centre dealt with 171 cases concerning incorrect storage...... in 2013. Data show that advice from Medicine Information Centre pharmacists resulted medicine cost savings of DKK 13 million (approx. €1.7 million) in hospitals in the Capital Region for that year. Conclusions Substantial savings can be made by seeking the advice of a team of information pharmacists...

  18. Renewable energy for Canada's northern communities - quantifying potential fuel savings

    International Nuclear Information System (INIS)

    Brothers, C.

    1998-01-01

    The probable impact of renewable energy technologies on fuel consumption in Canada's remote northern communities was discussed. These communities currently meet their electricity requirements using expensive diesel powered generators. It was noted that change to renewable energy in Canada's remote communities will only be made if the economic benefits can be clearly demonstrated. A study was conducted in Cambridge Bay, Northwest Territories, in which electrical load requirements and wind and solar resource data from the community was acquired to estimate savings in diesel fuel consumption for various renewable energy technologies. Wind was found to provide the most fuel displacement and was considered to be the most appropriate technology for these communities. A photovoltaic (PV) system of equivalent size would have significantly less impact on fuel savings in a community like Cambridge Bay, in part because a PV system would be poorly correlated on a seasonal basis with the energy requirements of the community. A wind-diesel system would be the most advantageous in terms of fuel savings due to its relatively high capacity factor, and due to the fact that is it is available year around. 4 refs., 1 tab., 4 figs

  19. Potential for the Use of Energy Savings Performance Contracts to Reduce Energy Consumption and Provide Energy and Cost Savings in Non-Building Applications

    Energy Technology Data Exchange (ETDEWEB)

    Williams, Charles; Green, Andrew S.; Dahle, Douglas; Barnett, John; Butler, Pat; Kerner, David

    2013-08-01

    The findings of this study indicate that potential exists in non-building applications to save energy and costs. This potential could save billions of federal dollars, reduce reliance on fossil fuels, increase energy independence and security, and reduce greenhouse gas emissions. The Federal Government has nearly twenty years of experience with achieving similar energy cost reductions, and letting the energy costs savings pay for themselves, by applying energy savings performance contracts (ESPC) inits buildings. Currently, the application of ESPCs is limited by statute to federal buildings. This study indicates that ESPCs can be a compatible and effective contracting tool for achieving savings in non-building applications.

  20. Electricity consumption and energy savings potential of video game consoles in the United States

    Energy Technology Data Exchange (ETDEWEB)

    Hittinger, E.; Mullins, K.A.; Azevedo, I.L. [Department of Engineering and Public Policy, Carnegie Mellon University, Pittsburgh, PA 15213 (United States)

    2012-11-15

    Total energy consumption of video game consoles has grown rapidly in the past few decades due to rapid increases in market penetration, power consumption of the devices, and increasing usage driven by new capabilities. Unfortunately, studies investigating the energy impacts of these devices have been limited and potential responses, such as ENERGY STAR requirements, have been difficult to define and implement. We estimate that the total electricity consumption of video game consoles in the US was around 11 TWh in 2007 and 16 TWh in 2010 (approximately 1 % of US residential electricity consumption), an increase of almost 50 % in 3 years. However, any estimate of total game console energy consumption is highly uncertain, and we have determined that the key uncertainty is the unknown consumer behavior with regards to powering down the system after use. Even under this uncertainty, we demonstrate that the most effective energy-saving modification is incorporation of a default auto power down feature, which could reduce electricity consumption of game consoles by 75 % (10 TWh reduction of electricity in 2010), saving consumers over USD 1 billion annually in electricity bills. We conclude that using an auto power down feature for game consoles is at least as effective for reducing energy consumption as implementing a strict set of energy efficiency improvements for the devices, is much easier to implement given the nature of the video game console industry, and could be applied retroactively to currently deployed consoles through firmware updates.

  1. Potential Energy Savings in Refrigeration Systems Using Optimal Setpoints

    DEFF Research Database (Denmark)

    Larsen, Lars Finn Slot; Thybo, Claus

    2004-01-01

    Energy efficiency of refrigeration systems has gradually been improved with help of control schemes utilizing the more flexible components. This paper proposes an approach in line with this trend, where a suboptimal condenser pressure is found in order to minimize the energy consumption. The obje......Energy efficiency of refrigeration systems has gradually been improved with help of control schemes utilizing the more flexible components. This paper proposes an approach in line with this trend, where a suboptimal condenser pressure is found in order to minimize the energy consumption....... The objective is to give an idea of how this optimization scheme works as well as to show what amount of energy it is possible to save. A steady state model of a simple refrigeration system will be used as a basis for the optimization....

  2. The costs and potential savings of a novel telepaediatric service in Queensland

    Directory of Open Access Journals (Sweden)

    Scuffham Paul

    2007-03-01

    Full Text Available Abstract Background There are few cost-minimisation studies in telemedicine. We have compared the actual costs of providing a telepaediatric service to the potential costs if patients had travelled to see the specialist in person. Methods In November 2000, we established a novel telepaediatric service for selected regional hospitals in Queensland. Instead of transferring patients to Brisbane, the majority of referrals to specialists in Brisbane were dealt with via videoconference. Since the service began, 1499 consultations have been conducted for a broad range of paediatric sub-specialities including burns, cardiology, child development, dermatology, diabetes, endocrinology, gastroenterology, nephrology, neurology, oncology, orthopaedics, paediatric surgery and psychiatry. Results During a five year period, the total cost of providing 1499 consultations through the telepaediatric service was A$955,996. The estimated potential cost of providing an outpatient service to the same number of patients at the Royal Children's Hospital in Brisbane was A$1,553,264; thus, telepaediatric services resulted in a net saving of approximately A$600,000 to the health service provider. Conclusion Telepaediatrics was a cheaper method for the delivery of outpatient services when the workload exceeded 774 consultations. A sensitivity analysis showed that the threshold point was most sensitive to changes related to patient travel costs, coordinator salaries and videoconference equipment costs. The study showed substantial savings for the health department, mainly due to reduced costs associated with patient travel.

  3. Potential of energy savings in the hotel sector in Jordan

    Energy Technology Data Exchange (ETDEWEB)

    Ali, Yahya [Department of Humanities and Social Sciences, Faculty of Arts, Hashemite University, Zarqa 13115 (Jordan); Mustafa, Mairna [Department of Sustainable Tourism, Queen Rania' s Institute of Tourism and Heritage, Hashemite University, Zarqa 13115 (Jordan); Al-Mashaqbah, Shireen [International Office, Hashemite University, Zarqa 13115 (Jordan); Mashal, Kholoud [Department of Land Management and Environment, Faculty of Natural Resources and Environment, Hashemite University, Zarqa 13115 (Jordan); Mohsen, Mousa [Department of Mechanical Engineering, Faculty of Engineering, Hashemite University, Zarqa 13115 (Jordan)

    2008-11-15

    This paper presents some insights into Jordan's energy consumption in the tourist accommodation sector. The results of a recent survey on environmental performance in the tourist accommodation sector in Jordan were used to evaluate energy conservation in hotels. A survey was designed and distributed to hotels' managers and departments' supervisors in order to understand the environmental performance in the tourist accommodation sector in Jordan during the period 10-17 August 2006. Also some field visits were conducted to fully understand hotels interaction regarding the environment, in addition to help interpreting the results of the survey. The study is limited to all classified hotels in Jordan. It was found that lighting hotels' main building and outside areas, and air conditioning consume more electricity compared to other departments. The results show that few classified hotels already installed energy saving equipments, though, it was noticed that managers of one star hotels were not really willing to make such changes in their hotels, on the other hand, other classified hotels (2-5 star hotels) have shown a high willingness to make changes in their hotels to reduce the consumption of different types of energy. Hotel's classification played a significant role in explaining variations in most of the results, particularly when it comes to long-term investments to reduce energy consumption by using energy efficient appliances. Five and four star hotels were the most hotels willing to use energy efficient appliances to reduce energy consumption. The study suggested some strategies to help reduce the negative impacts of high energy consumption in hotels. These strategies include better insulation, and enhanced insulation for the hot water reticulation system. Moreover, enhancing and increasing the level of awareness among all hoteliers through a directed and well-designed campaign. Also offer interest free loans; and activate precise

  4. Potential of energy savings in the hotel sector in Jordan

    International Nuclear Information System (INIS)

    Ali, Yahya; Mustafa, Mairna; Al-Mashaqbah, Shireen; Mashal, Kholoud; Mohsen, Mousa

    2008-01-01

    This paper presents some insights into Jordan's energy consumption in the tourist accommodation sector. The results of a recent survey on environmental performance in the tourist accommodation sector in Jordan were used to evaluate energy conservation in hotels. A survey was designed and distributed to hotels' managers and departments' supervisors in order to understand the environmental performance in the tourist accommodation sector in Jordan during the period 10-17 August 2006. Also some field visits were conducted to fully understand hotels interaction regarding the environment, in addition to help interpreting the results of the survey. The study is limited to all classified hotels in Jordan. It was found that lighting hotels' main building and outside areas, and air conditioning consume more electricity compared to other departments. The results show that few classified hotels already installed energy saving equipments, though, it was noticed that managers of one star hotels were not really willing to make such changes in their hotels, on the other hand, other classified hotels (2-5 star hotels) have shown a high willingness to make changes in their hotels to reduce the consumption of different types of energy. Hotel's classification played a significant role in explaining variations in most of the results, particularly when it comes to long-term investments to reduce energy consumption by using energy efficient appliances. Five and four star hotels were the most hotels willing to use energy efficient appliances to reduce energy consumption. The study suggested some strategies to help reduce the negative impacts of high energy consumption in hotels. These strategies include better insulation, and enhanced insulation for the hot water reticulation system. Moreover, enhancing and increasing the level of awareness among all hoteliers through a directed and well-designed campaign. Also offer interest free loans; and activate precise standards and specifications

  5. Potential travel cost saving in urban public-transport networks using smartphone guidance

    Science.gov (United States)

    2018-01-01

    Public transport (PT) is a key element in most major cities around the world. With the development of smartphones, available journey planning information is becoming an integral part of the PT system. Each traveler has specific preferences when undertaking a trip, and these preferences can also be reflected on the smartphone. This paper considers transit assignment in urban public-transport networks in which the passengers receive smartphone-based information containing elements that might influence the travel decisions in relation to line loads, as well as passenger benefits, and the paper discusses the transition from the current widespread choosing approach to a personalized decision-making approach based on smartphone information. The approach associated with smartphone guidance that considers passengers’ preference on travel time, waiting time and transfer is proposed in the process of obtaining his/her preferred route from the potential travel routes generated by the Deep First Search (DFS) method. Two other approaches, based on the scenarios reflecting reality, include passengers with access to no real time information, and passengers that only have access to the arrival time at the platform are used as comparisons. For illustration, the same network proposed by Spiess and Florian is utilized on the experiments in an agent-based model. Two experiments are conducted respectively according to whether each passenger’s choosing method is consistent. As expected, the results in the first experiment showed that the travel for consistent passengers with smartphone guidance was clearly shorter and that it can reduce travel time exceeding 15% and weighted cost exceeding 20%, and the average saved time approximated 3.88 minutes per passenger. The second experiment presented that travel cost, as well as cost savings, gradually decreased by employing smartphone guidance, and the maximum cost savings accounted for 14.2% of the total weighted cost. PMID:29746528

  6. Potential travel cost saving in urban public-transport networks using smartphone guidance.

    Science.gov (United States)

    Song, Cuiying; Guan, Wei; Ma, Jihui

    2018-01-01

    Public transport (PT) is a key element in most major cities around the world. With the development of smartphones, available journey planning information is becoming an integral part of the PT system. Each traveler has specific preferences when undertaking a trip, and these preferences can also be reflected on the smartphone. This paper considers transit assignment in urban public-transport networks in which the passengers receive smartphone-based information containing elements that might influence the travel decisions in relation to line loads, as well as passenger benefits, and the paper discusses the transition from the current widespread choosing approach to a personalized decision-making approach based on smartphone information. The approach associated with smartphone guidance that considers passengers' preference on travel time, waiting time and transfer is proposed in the process of obtaining his/her preferred route from the potential travel routes generated by the Deep First Search (DFS) method. Two other approaches, based on the scenarios reflecting reality, include passengers with access to no real time information, and passengers that only have access to the arrival time at the platform are used as comparisons. For illustration, the same network proposed by Spiess and Florian is utilized on the experiments in an agent-based model. Two experiments are conducted respectively according to whether each passenger's choosing method is consistent. As expected, the results in the first experiment showed that the travel for consistent passengers with smartphone guidance was clearly shorter and that it can reduce travel time exceeding 15% and weighted cost exceeding 20%, and the average saved time approximated 3.88 minutes per passenger. The second experiment presented that travel cost, as well as cost savings, gradually decreased by employing smartphone guidance, and the maximum cost savings accounted for 14.2% of the total weighted cost.

  7. Potential emissions savings of lightweight composite aircraft components evaluated through life cycle assessment

    Directory of Open Access Journals (Sweden)

    2011-03-01

    Full Text Available A cradle-to-grave life cycle assessment (LCA of structural aircraft materials has been utilised to assess and compare the total emissions produced during manufacturing, use and disposal of aerospace materials and their selected components. First, a comparison of aluminium, GLARE and carbon fibre reinforced polymer (CFRP plates was performed to investigate the potential of lightweight composites in reducing aviation emissions. Subsequently, a case study is presented on a tubular component for which more accurate manufacturing data were directly available. A structural steel tube was replaced with a composite tubular component. The analysis has shown that once the composite material is used as a component in the aircraft, there is a cumulative saving of aircraft fuel and emissions, in particular from CFRP structures. The environmental analysis included the long-term use predictions for CFRPs, involving detailed raw materials production, use and operation, and disposal scenarios.

  8. Implementing Suicide Prevention Programs: Costs and Potential Life Years Saved in Canada.

    Science.gov (United States)

    Vasiliadis, Helen-Maria; Lesage, Alain; Latimer, Eric; Seguin, Monique

    2015-09-01

    Little is known about the costs and effects of suicide prevention programs at the population level. We aimed to determine (i) the costs associated with a suicide death and using prospective values (ii) the costs and effects of transferring, into a Canadian context, the results of the European Nuremberg Alliance against Depression (NAD) trial with the addition of 4 community-based suicide prevention strategies. These included the training of family physicians in the detection and treatment of depression, population campaigns aimed at increasing awareness about depression, the training of community leaders among first responders and follow-up of individuals who attempted suicide. This study includes a prospective value implementation study design. Using published data and information from interviews with Canadian decision makers, we assessed the costs of a suicide death in the province of Quebec and the costs of potentially implementing the NAD multi-modal suicide prevention programs, and the incremental cost-effectiveness ratio (ICER), from a health care system and societal perspective, associated with the NAD program while considering the friction cost method (FCM) and human capital approach (HCA) (discounted at 3%.) The costs considered included those incurred for the suicide prevention program and direct medical and non-medical costs as well as those related to a police investigation and funeral costs. Indirect costs associated with loss of productivity and short term disability were also considered. Sensitivity analyses were also carried out. Costs presented were in 2010 dollars. The annual total cost of implementing the suicide prevention programs in Quebec reached CAD23,982,293. The most expensive components of the program included the follow-up of individuals who had attempted suicide and psychotherapy for bereaved individuals. These accounted for 39% and 34% of total costs. The ICER associated with the implementation of the programs reached on average CAD3

  9. Maximum potential cost-savings attributable to generic substitution ...

    African Journals Online (AJOL)

    D. Husselmann

    community. ... Conclusions: Potential economic benefits can be generated with generic substitution. ... Available online at www.sciencedirect.com ... supply of safe, cost-effective drugs of acceptable quality to all citizens of South Africa, and the rational use of drugs by .... different types of schizophrenic diagnosis) with a claim.

  10. Energy saving analysis and management modeling based on index decomposition analysis integrated energy saving potential method: Application to complex chemical processes

    International Nuclear Information System (INIS)

    Geng, Zhiqiang; Gao, Huachao; Wang, Yanqing; Han, Yongming; Zhu, Qunxiong

    2017-01-01

    Highlights: • The integrated framework that combines IDA with energy-saving potential method is proposed. • Energy saving analysis and management framework of complex chemical processes is obtained. • This proposed method is efficient in energy optimization and carbon emissions of complex chemical processes. - Abstract: Energy saving and management of complex chemical processes play a crucial role in the sustainable development procedure. In order to analyze the effect of the technology, management level, and production structure having on energy efficiency and energy saving potential, this paper proposed a novel integrated framework that combines index decomposition analysis (IDA) with energy saving potential method. The IDA method can obtain the level of energy activity, energy hierarchy and energy intensity effectively based on data-drive to reflect the impact of energy usage. The energy saving potential method can verify the correctness of the improvement direction proposed by the IDA method. Meanwhile, energy efficiency improvement, energy consumption reduction and energy savings can be visually discovered by the proposed framework. The demonstration analysis of ethylene production has verified the practicality of the proposed method. Moreover, we can obtain the corresponding improvement for the ethylene production based on the demonstration analysis. The energy efficiency index and the energy saving potential of these worst months can be increased by 6.7% and 7.4%, respectively. And the carbon emissions can be reduced by 7.4–8.2%.

  11. Fossil energy savings potential of sugar cane bio-energy systems

    DEFF Research Database (Denmark)

    Nguyen, Thu Lan T; Hermansen, John Erik; Sagisaka, Masayuki

    2009-01-01

    One important rationale for bio-energy systems is their potential to save fossil energy. Converting a conventional sugar mill into a bio-energy process plant would contribute to fossil energy savings via the extraction of renewable electricity and ethanol substituting for fossil electricity...... and gasoline, respectively. This paper takes a closer look at the Thai sugar industry and examines two practical approaches that will enhance fossil energy savings. The first one addresses an efficient extraction of energy in the form of electricity from the excess bagasse and cane trash. The second while...... proposing to convert molasses or sugar cane to ethanol stresses the use of bagasse as well as distillery spent wash to replace coal in meeting ethanol plants' energy needs. The savings potential achieved with extracting ethanol from surplus sugar versus current practice in sugar industry in Thailand amounts...

  12. Bivalent heating systems - Potential for savings through system optimisation

    International Nuclear Information System (INIS)

    Good, J.; Jenni, A.; Nussbaumer, T.

    2005-01-01

    This article tales a look at the potential for optimising bivalent heating installations for district heating systems fired with oil and wood. The influence of increases in the price of heating oil as compared to wood fuels is discussed. The authors comment that the proportion of expensive heating oil used in such installations is often too high. Price developments for both classes of fuel in 2005 are discussed. Factors influencing the proportions of oil and wood fuel used are listed and discussed, as is the mode of operation of the district heating systems, their extension and the consumers connected to them. The article provides information on the performance of 30 installations examined. Measures that can be taken to reduce the amount of heating oil used and to increase installation efficiency are presented and discussed

  13. Potential savings from an evidence-based consumer-oriented public education campaign on prescription drugs.

    Science.gov (United States)

    Donohue, Julie M; Fischer, Michael A; Huskamp, Haiden A; Weissman, Joel S

    2008-10-01

    To estimate potential savings associated with the Consumer Reports Best Buy Drugs program, a national educational program that provides consumers with price and effectiveness information on prescription drugs. National data on 2006 prescription sales and retail prices paid for angiotensin-converting enzyme inhibitors (ACEIs), β-blockers, calcium channel blockers, and 3-hydroxy-3-methylglutaryl coenzyme A (HMG-coA) reductase inhibitors (statins). We converted national data on aggregate unit sales of drugs in the four classes to defined daily doses (DDD) and estimated a range of potential savings from generic and therapeutic substitution. We estimated that $2.76 billion, or 7.83 percent of sales, could be saved if use of the drugs recommended by the educational program was increased. The recommended drugs' prices were 15-65 percent lower per DDD than their therapeutic alternatives. The majority (57.4 percent) of potential savings would be achieved through therapeutic substitution. Substantial savings can be achieved through greater use of comparatively effective and lower cost drugs recommended by a national consumer education program. However, barriers to dissemination of consumer-oriented drug information must be addressed before savings can be realized. © Health Research and Educational Trust.

  14. Identifying electricity-saving potential in rural China: Empirical evidence from a household survey

    International Nuclear Information System (INIS)

    Yu, Yihua; Guo, Jin

    2016-01-01

    In recent years, there has been a fast-growing body of literature examining energy-saving potential in relation to electricity. However, empirical studies focusing on non-Western nations are limited. To fill this gap, this study intends to examine the electricity-saving potential of rural households in China using a unique data set from the China Residential Electricity Consumption Survey (CRECS) in collaboration with the China General Social Survey (CGSS), conducted nationwide at the household level in rural China. We use a stochastic frontier model, which allows us to decompose residential electricity consumption into the minimum necessary amount of consumption based on physical characteristics (e.g. house size, house age, number of televisions or refrigerators) and estimate the consumption slack (i.e. the amount of electricity consumption that could be saved), which depends on various factors. We find that rural households in China are generally efficient in electricity saving and the saving potential is affected by (fast) information feedback and social-demographic characteristics, instead of by the (averaged) electricity price, or energy efficiency labelling signals. In addition, we find no evidence of regional heterogeneity on electricity saving potential for rural households. Policy implications are derived. - Highlights: •Electricity saving potential of rural households in China is examined. •Unique survey data from the CRECS in collaboration with the CGSS are used. •A stochastic frontier model is applied. •Information feedback and social-demographic characteristics matter. •Electricity price or energy efficiency tier rating does not matter.

  15. Rising Use Of Observation Care Among The Commercially Insured May Lead to Total And Out-Of-Pocket Cost Savings.

    Science.gov (United States)

    Adrion, Emily R; Kocher, Keith E; Nallamothu, Brahmajee K; Ryan, Andrew M

    2017-12-01

    Proponents of hospital-based observation care argue that it has the potential to reduce health care spending and lengths-of-stay, compared to short-stay inpatient hospitalizations. However, critics have raised concerns about the out-of-pocket spending associated with observation care. Recent reports of high out-of-pocket spending among Medicare beneficiaries have received considerable media attention and have prompted direct policy changes. Despite the potential for changed policies to indirectly affect non-Medicare patients, little is known about the use of, and spending associated with, observation care among commercially insured populations. Using multipayer commercial claims for the period 2009-13, we evaluated utilization and spending among patients admitted for six conditions that are commonly managed with either observation care or short-stay hospitalizations. In our study period, the use of observation care increased relative to that of short-stay hospitalizations. Total and out-of-pocket spending were substantially lower for observation care, though both grew rapidly-and at rates much higher than spending in the inpatient setting-over the study period. Despite this growth, spending on observation care is unlikely to exceed spending for short-stay hospitalizations. As observation care attracts greater attention, policy makers should be aware that Medicare policies that disincentivize observation may have unintended financial impacts on non-Medicare populations, where observation care may be cost saving.

  16. Potential energy savings in renovation projects of residential and service buildings; Energiansaeaestoemahdollisuudet rakennuskannan korjaustoiminnassa

    Energy Technology Data Exchange (ETDEWEB)

    Heljo, J.; Vihola, J.

    2012-11-01

    The study estimates the feasible energy savings potential in the 2010 building stock by 2050. The focus is on energy-saving measures related to renovation of residential and service buildings. The calculations were done by building types and age groups using the EKOREM calculation model. The calculations indicate the building types and structural elements where potential for savings exists. The study did not consider energy-saving measures related to changes in heating systems, electrical equipment, property maintenance or use habits. The study disproved the common belief that considerably more energy savings could be achieved faster by focussing on the existing building stock instead of new construction. That is mainly due the fact that it generally pays to implement structural energy-saving measures only when the targeted elements also require other significant repairs besides energy-efficiency improvements. Thus, energy renovations cannot be speeded up very much. The clearest exception are the extra insulations added to roof assemblies that are easy to implement. Attempts to save more energy in the building stock than can be achieved at a small additional cost in connection with needed renovations may multiply costs, and the saving in energy costs will not necessarily cover the additional investments. The efficiency of energy-saving measures can be affected by recommending or ordering use of more energy efficient windows, thicker extra insulations or more efficient ventilation heat recovery systems than the standard solution selected in connection with renovations. The goal of preserving the characteristics of buildings of cultural-historical or architectural value and the typical solutions and materials used in all buildings of a certain period limit the repair and renovation of structural elements. In the case of these buildings, improvement of energy efficiency can be considered in connection with the planning of renovations and the buildings' use and

  17. Potential energy savings using dynamically optimizing control in refrigeration systems under daily variations in ambient temperature

    DEFF Research Database (Denmark)

    Larsen, Lars Finn Sloth; Thybo, Claus; Wisniewski, Rafal

    2007-01-01

    The objective of this study is to investigate the energy saving potential for refrigeration systems by refrigeration more at the colder night time than at the warmer day time. The potential is evaluated using an optimal control policy and illustrated on a simulation example. The results show...

  18. Estimating potential saving with energy consumption behaviour model in higher education institutions

    Directory of Open Access Journals (Sweden)

    Mohd Hafizal Ishak

    2016-11-01

    Full Text Available Towards sustainable Higher Education Institutions (HEIs, energy consumption behaviour is one of several issues that require an attention by facilities manager. Information from the behavioural aspect would be useful for facilities manager on managing the energy and determining potential energy saving. A lack of information negatively affects this aim. Hence, this paper proposes a methodology for assessing the energy consumption behaviour with the objective determining potential energy saving. The method used energy culture framework as basis and joined with centrographic approach and multiple-regression analysis. A self-administrated survey carried out involving 1400 respondents in selected HEIs. There are four types of energy use among students in HEIs namely, 'high', 'low', ‘medium’ and 'conserve' determined from the centrographic analysis. The energy consumption behaviour model was developed and tested against the holdout sample. Through the model's application, there is a vast potential for energy savings with over 55 kWh daily among the students.

  19. Energy Saving Potential of PCMs in Buildings under Future Climate Conditions

    Directory of Open Access Journals (Sweden)

    Abdo Abdullah Ahmed Gassar

    2017-11-01

    Full Text Available Energy consumption reduction under changing climate conditions is a major challenge in buildings design, where excessive energy consumption creates an economic and environmental burden. Improving thermal performance of the buildings through support applying phase change material (PCM is a promising strategy for reducing building energy consumption under future climate change. Therefore, this study aims to investigate the energy saving potentials in buildings under future climate conditions in the humid and snowy regions in the hot continental and humid subtropical climates of the east Asia (Seoul, Tokyo and Hong Kong when various PCMs with different phase change temperatures are applied to a lightweight building envelope. Methodology in this work is implemented in two phases: firstly, investigation of energy saving potentials in buildings through inclusion of three types of PCMs with different phase temperatures into the building envelop separately and use weather file in the present (2017; and, secondly, evaluation of the effect of future climate change on the performance of PCMs by analyzing energy saving potentials of PCMs with 2020, 2050 and 2080 weather data. The results show that the inclusion of PCM into the building envelope is a promising strategy to increase the energy performance in buildings during both heating and cooling seasons in Seoul, Tokyo and Hong Kong under future climate conditions. The energy savings achieved by using PCMs in those regions are electricity savings of 4.48–8.21%, 3.81–9.69%, and 1.94–5.15%, and gas savings of 1.65–16.59%, 7.60–61.76%, and 62.07–93.33% in Seoul, Tokyo and Hong Kong, respectively, for the years 2017, 2020, 2050 and 2080. In addition, BioPCM and RUBITHERMPCM are the most efficient for improving thermal performance and saving energy in buildings in the tested regions and years.

  20. Max Tech Appliance Design: Potential for Maximizing U.S. Energy Savings through Standards

    Energy Technology Data Exchange (ETDEWEB)

    Garbesi, Karina; Desroches, Louis-Benoit; Bolduc, Christopher; Burch, Gabriel; Hosseinzadeh, Griffin; Saltiel, Seth

    2011-05-06

    This study surveyed the technical potential for efficiency improvements in 150 categories of appliances and equipment representing 33 quads of primary energy use across the US economy in 2010 and (1) documented efficient product designs, (2) identified the most promising cross-cutting strategies, and (3) ranked national energy savings potential by end use. Savings were estimated using a method modeled after US Department of Energy priority-setting reports - simplified versions of the full technical and economic analyses performed for rulemakings. This study demonstrates that large savings are possible by replacing products at the end-of-life with ultra-efficient models that use existing technology. Replacing the 50 top energy-saving end-uses (constituting 30 quads of primary energy consumption in 2010) with today's best-on-market equivalents would save {approx}200 quads of US primary energy over 30 years (25% of consumption anticipated there from). For the 29 products for maximum feasible savings potential could be estimated, the savings were twice as high. These results demonstrate that pushing ultra-efficient products to market could significantly escalate carbon emission reductions and is a viable strategy for sustaining large emissions reductions through standards. The results of this analysis were used by DOE for new coverage prioritization, to identify key opportunities for product prototyping and market development, and will leverage future standards rulemakings by identifying the full scope of maximum feasible technology options. High leverage products include advances lighting systems, HVAC, and televisions. High leverage technologies include electronic lighting, heat pumps, variable speed motors, and a host of controls-related technologies.

  1. Fossil energy savings potential of sugar cane bio-energy systems

    Energy Technology Data Exchange (ETDEWEB)

    Nguyen, Thu Lan T. [Department of Agroecology, Aarhus University, Tjele (Denmark); The Joint Graduate School of Energy and Environment, King Mongkut' s University of Technology Thonburi, Bangkok (Thailand); Hermansen, John E. [Department of Agroecology, Aarhus University, Tjele (Denmark); Sagisaka, Masayuki [Institute of Science for Safety and Sustainability, National Institute of Advanced Industrial Science and Technology, Tsukuba (Japan)

    2009-11-15

    One important rationale for bio-energy systems is their potential to save fossil energy. Converting a conventional sugar mill into a bio-energy process plant would contribute to fossil energy savings via the extraction of renewable electricity and ethanol substituting for fossil electricity and gasoline, respectively. This paper takes a closer look at the Thai sugar industry and examines two practical approaches that will enhance fossil energy savings. The first one addresses an efficient extraction of energy in the form of electricity from the excess bagasse and cane trash. The second while proposing to convert molasses or sugar cane to ethanol stresses the use of bagasse as well as distillery spent wash to replace coal in meeting ethanol plants' energy needs. The savings potential achieved with extracting ethanol from surplus sugar versus current practice in sugar industry in Thailand amounts to 15 million barrels of oil a year. Whether the saving benefits could be fully realized, however, depends on how well the potential land use change resulting from an expansion of ethanol production is managed. The results presented serve as a useful guidance to formulate strategies that enable optimum utilization of biomass as an energy source. (author)

  2. Bandwidth Study on Energy Use and Potential Energy Saving Opportunities in U.S. Pulp and Paper Manufacturing

    Energy Technology Data Exchange (ETDEWEB)

    Sabine Brueske, Caroline Kramer, Aaron Fisher

    2015-06-01

    Energy bandwidth studies of U.S. manufacturing sectors can serve as foundational references in framing the range (or bandwidth) of potential energy savings opportunities. This bandwidth study examines energy consumption and potential energy savings opportunities in U.S. pulp and paper manufacturing. The study relies on multiple sources to estimate the energy used in six individual process areas, representing 52% of sector-wide energy consumption. Energy savings opportunities for individual processes are based on technologies currently in use or under development; the potential savings are then extrapolated to estimate sector-wide energy savings opportunity

  3. Bandwidth Study on Energy Use and Potential Energy Saving Opportunities in U.S. Iron and Steel Manufacturing

    Energy Technology Data Exchange (ETDEWEB)

    Keith Jamison, Caroline Kramer, Sabine Brueske, Aaron Fisher

    2015-06-01

    Energy bandwidth studies of U.S. manufacturing sectors can serve as foundational references in framing the range (or bandwidth) of potential energy savings opportunities. This bandwidth study examines energy consumption and potential energy savings opportunities in U.S. iron and steel manufacturing. The study relies on multiple sources to estimate the energy used in six individual process areas and select subareas, representing 82% of sector-wide energy consumption. Energy savings opportunities for individual processes and subareas are based on technologies currently in use or under development; the potential savings are then extrapolated to estimate sector-wide energy savings opportunity.

  4. Potential energy savings with personalized ventilation coupled with passive chilled beams

    DEFF Research Database (Denmark)

    Lyubenova, Velina S.; Holsøe, Jan W.; Melikov, Arsen Krikor

    2011-01-01

    Personalized ventilation (PV) is an individually controlled air distribution system aimed at improving inhaled air quality and thermal comfort of each occupant. Numerous studies have shown that PV may improve occupants’ health, comfort and performance in comparison with traditional total volume air...... saving especially in spaces where occupants spend most of the time at their workplace....

  5. IMPLEMENTASI DISTRIBUSI REQUIREMENT PLANNING DAN SAVING MATRIX UNTUK MEMINIMASI TOTAL BIAYA DISTRIBUSI DI INDUSTRI BAHAN KIMIA

    Directory of Open Access Journals (Sweden)

    Johan Oscar Ong

    2013-12-01

    Full Text Available Planning and scheduling of the distribution of goods in PT. Senatama Laboranusa are not well coordinated, so the demand for each product is out of control, which results in deficiency or excess of inventories in both of the factories and each warehouse. This problem will affect the distribution cost incurred by the company. In this study, the distribution data process is done by using Distribution Requirement Planning method and route distribution processing by using Saving Matrix, in which both of these methods can group the delivery schedule and flow of distribution route regularly. PO Release, which contains time, order amount of each area, and lot size EOQ (Economic Order Quantity method used; will be generated from the calculation of DRP. From the calculation of Saving Matrix, route order sequence is applied by using Nearest Neighbor method. After the implementation of Distribution Requirement Planning, the cost reduction resulted is 29.75% and the difference in distance after the application of Saving Matrix is 983.3 Km. With a good distribution activity planning and scheduling, the success rate in meeting the customer demand would be more optimal, while sales performance increases in fulfilling orders in a timely manner and  appropriate amount, hence the distribution costs can be kept as minimum as possible.

  6. A comprehensive framework to quantify energy savings potential from improved operations of commercial building stocks

    International Nuclear Information System (INIS)

    Azar, Elie; Menassa, Carol C.

    2014-01-01

    While studies highlight the significant impact of actions performed by occupants and facility managers on building energy performance, current policies ignore the importance of human actions and the potential energy savings from a more efficient operation of building systems. This is mainly attributed to the lack of methods that evaluate non-technological drivers of energy use for large stocks of commercial buildings to support policy making efforts. Therefore, this study proposes a scientific approach to quantifying the energy savings potential due to improved operations of any stock of commercial buildings. The proposed framework combines energy modeling techniques, studies on human actions in buildings, and surveying and sampling methods. The contributions of this study to energy policy are significant as they reinforce the role of human actions in energy conservation, and support efforts to integrate operation-focused solutions in energy conservation policy frameworks. The framework's capabilities are illustrated in a case study performed on the stock of office buildings in the United States (US). Results indicate a potential 21 percent reduction in the current energy use levels of these buildings through realistic changes in current building operation patterns. - Highlights: • Human actions highly influence energy performance of commercial building stocks. • It is challenging to quantify operation-related energy savings potential. • The proposed framework quantifies potential energy savings from improved operations. • The framework can be applied on any stock of commercial buildings. • Applications include support for operation-focused solutions in energy policies

  7. Potential savings from redetermining disability among children receiving supplemental security income benefits.

    Science.gov (United States)

    Pulcini, Christian D; Kotelchuck, Milton; Kuhlthau, Karen A; Nozzolillo, Alixandra A; Perrin, James M

    2012-01-01

    To compare the costs of redetermining disability to potential savings in Supplemental Security Income payments associated with different strategies for implementing Continuing Disability Reviews (CDRs) among children potentially enrolled in SSI from 2012 to 2021. We reviewed publicly available reports from the Social Security Administration and Government Accountability Office to estimate costs and savings. We considered CDRs for children ages 1-17 years, excluding mandated low-birth weight and age 18 redeterminations that SSA routinely has performed. If in 2012 the Social Security Administration performs the same number of CDRs for children as in 2010 (16,677, 1% of eligibles) at a cessation rate of 15%, the agency would experience net savings of approximately $145 million in benefit payments. If CDR numbers increased to the greatest level ever (183,211, 22% of eligibles, in 1999) at the same cessation rate, the agency would save approximately $1.6 billion in benefit payments. Increasing the numbers of CDRs for children represents a considerable opportunity for savings. Recognizing the dynamic nature of disability, the agency could reassess the persistence of disability systematically; doing so could free up resources from children who are no longer eligible and help the agency better direct its benefits to recipients with ongoing disability and whose families need support to meet the extra costs associated with raising a child with a major disability. Copyright © 2012 Academic Pediatric Association. Published by Elsevier Inc. All rights reserved.

  8. Some Environmental and Economic Aspects of Energy Saving Measures in Houses. An estimation model for total energy consumption and emissions to air from the Norwegian dwelling stock, and a life cycle assessment method for energy saving measures in houses

    Energy Technology Data Exchange (ETDEWEB)

    Myhre, L

    1995-12-01

    Motivated by the need to reduce the total energy consumption and the environmental load from society, this doctoral thesis discusses energy conservation measures on existing houses. Alternative additional thermal insulation measures are assessed using an interdisciplinary life cycle approach. The first task is to develop an interdisciplinary assessment method for building improvement measures, taking account of energy consumption, resource consumption, emissions to air of environmentally harmful gases, and economic costs during the entire life cycle of the building. The second task is to develop an estimation model for the total energy consumption and emissions to air of environmentally harmful gases from the dwelling stock of Norway. Finally, the third task is to assess the total energy saving potential and the total environmental benefits of energy saving measures in houses on a national level, including only life cycle analyses of additional thermal insulation measures on single houses. Chap 2 describes the dwelling stock in Norway. Chaps 3 and 4 present an estimation model for total energy consumption and emissions to air from the dwelling stock, and calculations using the model. Chaps 5 and 6 propose and use a calculation method for the assessment of additional thermal insulation measures, using a ``cradle-to-grave`` approach. Since hydroelectric power is the main energy source in this sector in Norway, estimated payback periods for emissions to air are long. But hydroelectric power saved in this sector may be used to obtain reduction in fossil fuel use in other sectors as discussed in Chap 7. Some of the topics discussed are further elaborated on in appendices. 107 refs., 39 figs, 88 tabs.

  9. Shortened first-line TB treatment in Brazil: potential cost savings for patients and health services

    NARCIS (Netherlands)

    Trajman, Anete; Bastos, Mayara Lisboa; Belo, Marcia; Calaça, Janaína; Gaspar, Júlia; Dos Santos, Alexandre Martins; Dos Santos, Camila Martins; Brito, Raquel Trindade; Wells, William A.; Cobelens, Frank G.; Vassall, Anna; Gomez, Gabriela B.

    2016-01-01

    Shortened treatment regimens for tuberculosis are under development to improve treatment outcomes and reduce costs. We estimated potential savings from a societal perspective in Brazil following the introduction of a hypothetical four-month regimen for tuberculosis treatment. Data were gathered in

  10. Analysis of Energy Saving Potential and Optimization of Thermally Broken Fiberglass Window Frames

    DEFF Research Database (Denmark)

    Zajas, Jan Jakub; Heiselberg, Per

    2011-01-01

    This paper elaborates on the energy saving potential and development process of fiberglass window frames, with intention for application in cold climates. A method is presented, where different means of improving thermal performance of a window frame are evaluated. Firstly, very simple geometries...

  11. Energy Savings Potential and Opportunities for High-Efficiency Electric Motors in Residential and Commercial Equipment

    Energy Technology Data Exchange (ETDEWEB)

    Goetzler, William [Navigant Consulting, Inc., Burlington, MA (United States); Sutherland, Timothy [Navigant Consulting, Inc., Burlington, MA (United States); Reis, Callie [Navigant Consulting, Inc., Burlington, MA (United States)

    2013-12-04

    This report describes the current state of motor technology and estimates opportunities for energy savings through application of more advanced technologies in a variety of residential and commercial end uses. The objectives of this report were to characterize the state and type of motor technologies used in residential and commercial appliances and equipment and to identify opportunities to reduce the energy consumption of electric motor-driven systems in the residential and commercial sectors through the use of advanced motor technologies. After analyzing the technical savings potential offered by motor upgrades and variable speed technologies, recommended actions are presented.

  12. Energy Savings Potential and Research, Development, & Demonstration Opportunities for Commercial Building Appliances

    Energy Technology Data Exchange (ETDEWEB)

    Zogg, Robert [Navigant Consulting, Inc., Burlington, MA (United States); Goetzler, William [Navigant Consulting, Inc., Burlington, MA (United States); Ahlfeldt, Christopher [Navigant Consulting, Inc., Burlington, MA (United States); Hiraiwa, Hirokazu [Navigant Consulting, Inc., Burlington, MA (United States); Sathe, Amul [Navigant Consulting, Inc., Burlington, MA (United States); Sutherland, Timothy [Navigant Consulting, Inc., Burlington, MA (United States)

    2009-12-01

    This study characterizes and assesses the appliances used in commercial buildings. The primary objectives of this study were to document the energy consumed by commercial appliances and identify research, development and demonstration (RD&D) opportunities for efficiency improvements, excluding product categories such as HVAC, building lighting, refrigeration equipment, and distributed generation systems. The study included equipment descriptions, characteristics of the equipment’s market, national energy consumption, estimates of technical potential for energy-saving technologies, and recommendations for U.S. Department of Energy programs that can promote energy savings in commercial appliances.

  13. Realistic Energy Saving Potential of Sleep Mode for Existing and Future Mobile Networks

    DEFF Research Database (Denmark)

    Micallef, Gilbert; Saker, Louai; Elayoubi, Salah Eddine

    2012-01-01

    potential savings, and emphasize some of the expected limitations. Since site measurements show that the energy consumption of base station sites is largely load-independent, this makes such a feature highly effective for reducing the energy consumption of mobile networks during hours of low traffic. After......This paper presents an extensive overview on an energy saving feature referred to as ‘site sleep mode’, designed for existing and future mobile broadband networks. In addition to providing a detailed understanding of the main concept, the paper also provides various studies and results to highlight...

  14. Potential electricity savings by variable speed control of compressor for air conditioning systems

    Energy Technology Data Exchange (ETDEWEB)

    Nasution, Henry [Bung Hatta University, Department of Mechanical Engineering, Faculty of Industrial Engineering, Padang, West Sumatera (Indonesia); Wan Hassan, Mat Nawi [Universiti Teknologi Malaysia, Faculty of Mechanical Engineering, Skudai, Johor Bahru-Darul Ta' zim (Malaysia)

    2006-05-15

    The potential of a variable-speed compressor running on a controller to provide enhanced load-matching capability, energy saving and thermal comfort for application in air-conditioning system is demonstrated. An air-conditioning system, originally operated on a constant speed mode, is retrofitted with an inverter and a PID controller. The system was installed to a thermal environmental room together with a data acquisition system to monitor energy consumption and temperature of the room. Measurements were taken 2 h daily at a time interval of 5 min for an on/off and an inverter variable-speed conditions. The results indicate that thermal comfort of the room together with energy saving can be obtained through a proper selection of K for the controller. At a temperature setting of 22 C, the energy saving for the system is estimated to reach 25.3% for PID controllers. (orig.)

  15. Fuel Savings Potential from Future In-motion Wireless Power Transfer (WPT); NREL (National Renewable Energy Laboratory)

    Energy Technology Data Exchange (ETDEWEB)

    Burton, E.; Wang, L.; Gonder, J.; Brooker, A.; Konan, A.

    2015-02-10

    This presentation discusses the fuel savings potential from future in-motion wireless power transfer. There is an extensive overlap in road usage apparent across regional vehicle population, which occurs primarily on high-capacity roads--1% of roads are used for 25% of the vehicle miles traveled. Interstates and highways make up between 2.5% and 4% of the total roads within the Consolidated Statistical Areas (CSAs), which represent groupings of metropolitan and/or micropolitan statistical areas. Mileage traveled on the interstates and highways ranges from 54% in California to 24% in Chicago. Road electrification could remove range restrictions of electric vehicles and increase the fuel savings of PHEVs or HEVs if implemented on a large scale. If 1% of the road miles within a geographic area are electrified, 25% of the fuel used by a 'fleet' of vehicles enabled with the technology could be displaced.

  16. Potential Cost Savings with 3D Printing Combined With 3D Imaging and CPLM for Fleet Maintenance and Revitalization

    Science.gov (United States)

    2014-05-01

    1 Potential Cost Savings with 3D Printing Combined With 3D Imaging and CPLM for Fleet Maintenance and Revitalization David N. Ford...2014 4. TITLE AND SUBTITLE Potential Cost Savings with 3D Printing Combined With 3D Imaging and CPLM for Fleet Maintenance and Revitalization 5a...Manufacturing ( 3D printing ) 2 Research Context Problem: Learning curve savings forecasted in SHIPMAIN maintenance initiative have not materialized

  17. Potential Cost Savings From Reduction of Regional Variation in Medicare Spending

    Directory of Open Access Journals (Sweden)

    Yunjie Song

    2016-04-01

    Full Text Available Potential cost savings estimated from reduction of regional variation in Medicare spending are considerable but questioned. This article evaluates the validity of the principal methods that have been used in the estimations of the potential savings. Three estimation approaches were identified. The first approach uses adjusted expenditures to calculate avoidable costs, but adjusted expenditures can be independent of avoidable costs, and measurement errors are not controlled. The second approach uses an outcome variable to replace its causal factors, and is not acceptable because the association between the outcomes and the causes is untestable. The final approach uses surveys to directly measure physician beliefs and patient preferences, but the sole study using this approach is weakened by sample selection biases and incomplete controls. A development of reliable measures and a switch of observation from clinic settings to geographic contexts could make the estimations more convincing.

  18. DSM Electricity Savings Potential in the Buildings Sector in APP Countries

    Energy Technology Data Exchange (ETDEWEB)

    McNeil, MIchael; Letschert, Virginie; Shen, Bo; Sathaye, Jayant; de la Ru du Can, Stephane

    2011-01-12

    The global economy has grown rapidly over the past decade with a commensurate growth in the demand for electricity services that has increased a country's vulnerability to energy supply disruptions. Increasing need of reliable and affordable electricity supply is a challenge which is before every Asia Pacific Partnership (APP) country. Collaboration between APP members has been extremely fruitful in identifying potential efficiency upgrades and implementing clean technology in the supply side of the power sector as well established the beginnings of collaboration. However, significantly more effort needs to be focused on demand side potential in each country. Demand side management or DSM in this case is a policy measure that promotes energy efficiency as an alternative to increasing electricity supply. It uses financial or other incentives to slow demand growth on condition that the incremental cost needed is less than the cost of increasing supply. Such DSM measures provide an alternative to building power supply capacity The type of financial incentives comprise of rebates (subsidies), tax exemptions, reduced interest loans, etc. Other approaches include the utilization of a cap and trade scheme to foster energy efficiency projects by creating a market where savings are valued. Under this scheme, greenhouse gas (GHG) emissions associated with the production of electricity are capped and electricity retailers are required to meet the target partially or entirely through energy efficiency activities. Implementation of DSM projects is very much in the early stages in several of the APP countries or localized to a regional part of the country. The purpose of this project is to review the different types of DSM programs experienced by APP countries and to estimate the overall future potential for cost-effective demand-side efficiency improvements in buildings sectors in the 7 APP countries through the year 2030. Overall, the savings potential is estimated to be

  19. China's energy saving potential from the perspective of energy efficiency advantages of foreign-invested enterprises

    International Nuclear Information System (INIS)

    Jiang, Xuemei; Zhu, Kunfu; Green, Christopher

    2015-01-01

    The paper investigates the energy saving potential associated with firm ownership-related differences in energy efficiency such as those between domestically and foreign-owned firms. Because of a gap in official statistics this topic has barely been touched upon in the scholarly literature. This paper employs a new energy input–output table that distinguishes firm ownership (Chinese owned enterprises, COEs; and foreign-invested enterprises, FIEs) and trade mode (export processing and normal goods production) to analyze the energy efficiency advantage of FIEs in China in 2007. The results show that the total energy intensities of COEs in the industrial sector are generally 5%–35% higher than that of FIEs across industry groups. At an aggregate level, China could save up to 20.3% of its energy use, if industrial COEs could duplicate the energy use efficiency and production technology of FIEs. This gain would require major technology upgrades among COEs. - Highlights: • A new input–output table distinguishing firm ownership and trade mode is employed. • The foreign-invested enterprises are 5%–35% energy efficient than Chinese enterprises in 2007. • China could save 20.3% of energy use if industrial COEs could duplicate the technologies of FIEs

  20. Cooling and energy saving potentials of shade trees and urban lawns in a desert city

    International Nuclear Information System (INIS)

    Wang, Zhi-Hua; Zhao, Xiaoxi; Yang, Jiachuan; Song, Jiyun

    2016-01-01

    Highlights: • We developed a numerical framework incorporating trees in an urban canopy model. • Shade trees have more prominent energy saving potential than urban lawns. • The trade-off between water-energy is a key for urban landscape management. • Urban vegetation can significantly alleviate outdoor thermal stress. - Abstract: The use of urban vegetation in cities is a common landscape planning strategy to alleviate the heat island effect as well as to enhance building energy efficiency. The presence of trees in street canyons can effectively reduce environmental temperature via radiative shading. However, resolving shade trees in urban land surface models presents a major challenge in numerical models, especially in predicting the radiative heat exchange in canyons. In this paper, we develop a new numerical framework by incorporating shade trees into an advanced single-layer urban canopy model. This novel numerical framework is applied to Phoenix metropolitan area to investigate the cooling effect of different urban vegetation types and their potentials in saving building energy. It is found that the cooling effect by shading from trees is more significant than that by evapotranspiration from lawns, leading to a considerable saving of cooling load. In addition, analysis of human thermal comfort shows that urban vegetation plays a crucial role in creating a comfortable living environment, especially for cities located in arid or semi-arid region.

  1. Energy Savings Potential and RD&D Opportunities for Commercial Building HVAC Systems

    Energy Technology Data Exchange (ETDEWEB)

    Goetzler, William [Navigant Consulting, Burlington, MA (United States); Shandross, Richard [Navigant Consulting, Burlington, MA (United States); Young, Jim [Navigant Consulting, Burlington, MA (United States); Petritchenko, Oxana [Navigant Consulting, Burlington, MA (United States); Ringo, Decker [Navigant Consulting, Burlington, MA (United States); McClive, Sam [Navigant Consulting, Burlington, MA (United States)

    2017-12-01

    The Building Technologies Office (BTO) commissioned this characterization and technology assessment of heating, ventilation, and air-conditioning (HVAC) systems for commercial buildings. The main objectives of this study: Identify a wide range of technology options in varying stages of development that could reduce commercial HVAC energy consumption; Characterize these technology options based on their technical energy-savings potential, development status, non-energy benefits, and other factors affecting end-user acceptance and the ability to compete with conventional HVAC technologies; Make specific recommendations to DOE and other stakeholders on potential research, development, and demonstration (RD&D) activities that would support further development of the most promising technology options.

  2. Energy and cost savings potential of oscillating heat pipes for waste heat recovery ventilation

    Directory of Open Access Journals (Sweden)

    Govinda Mahajan

    2017-11-01

    Full Text Available The feasibility of using finned oscillating heat pipes (OHPs for heat exchange between counter-flowing air streams in HVAC air systems (i.e., outdoor and exhaust air flows, along with the associated cost savings in typical North American climates, is investigated. For a prescribed temperature difference and volumetric flow rate of air, rudimentary design parameters for a viable OHP Heat Recovery Ventilator (OHP-HRV were determined using the ε-NTU (effectiveness-Number of Transfer Unit method. The two-phase heat transfer within the OHP-HRV is modeled via effective evaporation/condensation heat transfer coefficients, while the latent heat transfer required to initiate OHP operation via boiling and evaporation is also considered. Results suggest that an OHP-HRV can possess a reasonable pressure drop (5 kW. The proposed OHP-HRV can possess an effectiveness near 0.5 and can pre-cool/heat HVAC air by >5°C. Potential energy and cost savings associated with using an OHP-HRV were estimated for commercial building envelopes in various regions of the United States. It is found that the proposed OHP-HRV can save more than $2500 annually in cities that have continental climatic conditions, such as Chicago and Denver, and for the selected locations the average yearly cost savings per building is found to be on-the-order of $700. Overall, the OHP-HRV shows potential in effectively reducing energy consumption and the operational cost of air handling units in buildings.

  3. Potential time savings to radiology department personnel in a PACS-based environment

    Science.gov (United States)

    Saarinen, Allan O.; Wilson, M. C.; Iverson, Scott C.; Loop, John W.

    1990-08-01

    A purported benefit of digital imaging and archiving of radiographic procedures is the presumption of time savings to radiologists, radiology technologists, and radiology departmentpersonnel involved with processingfilms and managing theflimfile room. As part of the University of Washington's evaluation of Picture Archiving and Communication Systems (PACS)for the U.S. Army Medical Research and Development Command, a study was performed which evaluated the current operationalpractices of the film-based radiology department at the University of Washington Medical Center (UWMC). Industrial engineering time and motion studies were conducted to document the length of time requiredforfilm processing in various modalities, the proportion of the total exam time usedforfilm processing, the amount of time radiologists spent searchingfor and looking at images, and the amount of time file room personnel spent collating reports, making loans, updatingfilm jacket information, and purging files. This evaluation showed that better than one-half of the tasks in the file room may be eliminated with PACS and radiologists may save easily 10 percent of the time they spend reading films by no longer having to searchforfilms. Radiology technologists may also save as much as 10 percent of their time with PACS, although this estimate is subject to significant patient mix aberrations and measurement error. Given that the UWMC radiology department operates efficiently, similar improvements are forecast for other radiology departments and larger improvements areforecastfor less efficient departments.

  4. Energy saving potential of energy services - experimentation on the life cycle of energy conversion equipment

    International Nuclear Information System (INIS)

    Dupont, M.

    2006-12-01

    Energy efficiency services are growing in Europe but their role is still limited. In order to evaluate the potential, we focused first of all on policy, economical and environmental mechanisms that support their development. European natural gas and electricity markets, that are now almost wholly de-regulated, are analysed and compared to their historical structure. By introducing uncertainty on energy prices, this new deal translates better the real energy costs. Energy performance contracts (EPC) limit the impact of these uncertainties on the customer energy bills by guaranteeing a financial result. As a result of the modelling of these contracts, namely operation and maintenance ones, we prove that they transfer technical and financial risks from building owners to energy service companies (ESCO) making energy saving measures easier and less expensive at the same time. These contracts are relatively widespread for heating or compressed-air processes but remain marginal for air-conditioning systems. So new methods were needed to guarantee on the long terms the efficiency of air-conditioning systems demand (1) to master the process and its performances and (2) to be able to determine precisely the energy saving potential and its realisation costs. A detailed energy audit is thus necessary for which we propose a guidance. Conclusions of audits carried out prove that energy saving potential is mainly located in equipment management and control. These optimizations are not always carried out because of a lack of contractual incentive and due to the weaknesses of audit methods. Through the involvement of an independent expert, the mandatory and regular inspection of air-conditioning systems may allow to verify and guide such practices. A three-step analysis procedure has been developed in order to maximize the inspection potential and to get higher benefits from service contracts. (author)

  5. Energy usage and technical potential for energy saving measures in the Swedish residential building stock

    International Nuclear Information System (INIS)

    Mata, Érika; Sasic Kalagasidis, Angela; Johnsson, Filip

    2013-01-01

    This paper provides an analysis of the current energy usage (net energy and final energy by fuels) and associated carbon dioxide (CO 2 ) emissions of the Swedish residential building stock, which includes single-family dwellings and multi-family dwellings. Twelve energy saving measures (ESMs) are assessed using a bottom–up modeling methodology, in which the Swedish residential stock is represented by a sample of 1400 buildings (based on data from the year 2005). Application of the ESMs studied gives a maximum technical reduction potential in energy demand of 53%, corresponding to a 63% reduction in CO 2 emissions. Although application of the investigated ESMs would reduce CO 2 emissions, the measures that reduce electricity consumption for lighting and appliances (LA) will increase CO 2 emissions, since the saved electricity production is less CO 2 -intensive than the fuel mix used for the increased space heating required to make up for the loss in indirect heating obtained from LA. - Highlights: ► Analysis of year 2005energy use and CO2 emissions of Swedish residential buildings. ► Includes all single-family dwellings and multi-family dwellings. ► Bottom–up modeling of building stock represented by 1400 buildings. ► Technical effects of 12 energy saving measures are assessed. ► Energy demand can be reduced by53% and associated CO 2 emissions by 63%

  6. Development of a prediction model for the cost saving potentials in implementing the building energy efficiency rating certification

    International Nuclear Information System (INIS)

    Jeong, Jaewook; Hong, Taehoon; Ji, Changyoon; Kim, Jimin; Lee, Minhyun; Jeong, Kwangbok; Koo, Choongwan

    2017-01-01

    Highlights: • This study evaluates the building energy efficiency rating (BEER) certification. • Prediction model was developed for cost saving potentials by the BEER certification. • Prediction model was developed using LCC analysis, ROV, and Monte Carlo simulation. • Cost saving potential was predicted to be 2.78–3.77% of the construction cost. • Cost saving potential can be used for estimating the investment value of BEER. - Abstract: Building energy efficiency rating (BEER) certification is an energy performance certificates (EPCs) in South Korea. It is critical to examine the cost saving potentials of the BEER-certification in advance. This study aimed to develop a prediction model for the cost saving potentials in implementing the BEER-certification, in which the cost saving potentials included the energy cost savings of the BEER-certification and the relevant CO_2 emissions reduction as well as the additional construction cost for the BEER-certification. The prediction model was developed by using data mining, life cycle cost analysis, real option valuation, and Monte Carlo simulation. The database were established with 437 multi-family housing complexes (MFHCs), including 116 BEER-certified MFHCs and 321 non-certified MFHCs. The case study was conducted to validate the developed prediction model using 321 non-certified MFHCs, which considered 20-year life cycle. As a result, compared to the additional construction cost, the average cost saving potentials of the 1st-BEER-certified MFHCs in Groups 1, 2, and 3 were predicted to be 3.77%, 2.78%, and 2.87%, respectively. The cost saving potentials can be used as a guideline for the additional construction cost of the BEER-certification in the early design phase.

  7. Modeling and simulation to determine the potential energy savings by implementing cold thermal energy storage system in office buildings

    International Nuclear Information System (INIS)

    Rismanchi, B.; Saidur, R.; Masjuki, H.H.; Mahlia, T.M.I.

    2013-01-01

    Highlights: • Simulating the CTES system behavior based on Malaysian climate. • Almost 65% of power is used for cooling for cooling the office buildings, every day. • The baseline shows an acceptable match with real data from the fieldwork. • Overall, the energy used for full load storage is much than the conventional system. • The load levelling storage strategy has 3.7% lower energy demand. - Abstract: In Malaysia, air conditioning (AC) systems are considered as the major energy consumers in office buildings with almost 57% share. During the past decade, cold thermal energy storage (CTES) systems have been widely used for their significant economic benefits. However, there were always doubts about their energy saving possibilities. The main objective of the present work is to develop a computer model to determine the potential energy savings of implementing CTES systems in Malaysia. A case study building has been selected to determine the energy consumption pattern of an office building. In the first step the building baseline model was developed and validated with the recorded data from the fieldwork. Once the simulation results reach an acceptable accuracy, different CTES system configuration was added to the model to predict their energy consumption pattern. It was found that the overall energy used by the full load storage strategy is considerably more than the conventional system. However, by applying the load leveling storage strategy, and considering its benefits to reduce the air handling unit size and reducing the pumping power, the overall energy usage was almost 4% lower than the non-storage system. Although utilizing CTES systems cannot reduce the total energy consumption considerably, but it has several outstanding benefits such as cost saving, bringing balance in the grid system, reducing the overall fuel consumption in the power plants and consequently reducing to total carbon footprint

  8. Residential energy use in Mexico: Structure, evolution, environmental impacts, and savings potential

    Energy Technology Data Exchange (ETDEWEB)

    Masera, O.; Friedmann, R.; deBuen, O.

    1993-05-01

    This article examines the characteristics of residential energy use in Mexico, its environmental impacts, and the savings potential of the major end-uses. The main options and barriers to increase the efficiency of energy use are discussed. The energy analysis is based on a disaggregation of residential energy use by end-uses. The dynamics of the evolution of the residential energy sector during the past 20 years are also addressed when the information is available. Major areas for research and for innovative decision-making are identified and prioritized.

  9. Potential for Potable Water Savings in Buildings by Using Stormwater Harvested from Porous Pavements

    Directory of Open Access Journals (Sweden)

    Lucas Niehuns Antunes

    2016-03-01

    Full Text Available There is a growing concern about the scarcity of water resources due to population growth and increased demand for potable water. Thus, the rational use of water has become necessary for the conservation of such resources. The objective of this study is to estimate the potential for potable water savings in buildings of different sectors—residential, public and commercial—in the city of Florianópolis, southern Brazil, by using stormwater harvested from porous pavements. Models were constructed to assess infiltration and rainwater quality; samples of stormwater from a local road were collected to evaluate its quality; and computer simulation was performed to assess the potential for potable water savings and rainwater tank sizing. Draining asphalt concrete slabs with two types of modifiers were used, i.e., tire rubber and SBS polymer—styrene-butadiene-styrene. The Netuno computer programme was used to simulate the potential for potable water savings considering the use of rainwater for non-potable uses such as flushing toilets and urinals, cleaning external areas, and garden watering. Average stormwater infiltration was 85.4%. It was observed that stormwater is not completely pure. From the models, the pH was 5.4 and the concentrations of ammonia, phosphorus, nitrite, and dissolved oxygen were 0.41, 0.14, 0.002, and 9.0 mg/L, respectively. The results for the stormwater runoff of a paved road were 0.23, 0.11, 0.12, 0.08, 1.41, 2.11, 0.02, and 9.0 mg/L for the parameters aluminium, ammonia, copper, chromium, iron, phosphorus, nitrite, and dissolved oxygen, respectively; and the pH was 6.7. In the city of Florianópolis, which has a surface area of paved roads of approximately 11,044,216 m², the potential for potable water savings ranged from 1.2% to 19.4% in the residential sector, 2.1% to 75.7% in the public sector and 6.5% to 70.0% in the commercial sector.

  10. Fossil energy and GHG saving potentials of pig farming in the EU

    DEFF Research Database (Denmark)

    Nguyen, T Lan T; Mogensen, Lisbeth; Hermansen, John Erik

    2010-01-01

    ) savings can be feasibly achieved. As shown in the results of the analysis, pig farming in the EU has a high potential to reduce fossil energy use and GHG emissions by taking improvement measures in three aspects: (i) feed use; (ii) manure management; and (iii) manure utilization. In particular......In Europe, the highly developed livestock industry places a high burden on resource use and environmental quality. This paper examines pig meat production in North-West Europe as a base case and runs different scenarios to investigate how improvements in terms of energy and greenhouse gas (GHG...

  11. Web-based Tool Identifies and Quantifies Potential Cost Savings Measures at the Hanford Site

    International Nuclear Information System (INIS)

    Renevitz, Marisa J.; Peschong, Jon C.; Charboneau, Briant L.; Simpson, Brett C.

    2014-01-01

    The Technical Improvement system is an approachable web-based tool that is available to Hanford DOE staff, site contractors, and general support service contractors as part of the baseline optimization effort underway at the Hanford Site. Finding and implementing technical improvements are a large part of DOE's cost savings efforts. The Technical Improvement dashboard is a key tool for brainstorming and monitoring the progress of submitted baseline optimization and potential cost/schedule efficiencies. The dashboard is accessible to users over the Hanford Local Area Network (HLAN) and provides a highly visual and straightforward status to management on the ideas provided, alleviating the need for resource intensive weekly and monthly reviews

  12. Effective Form of Reproducing the Total Financial Potential of Ukraine

    Directory of Open Access Journals (Sweden)

    Portna Oksana V.

    2015-03-01

    Full Text Available Development of scientific principles of reproducing the total financial potential of the country and its effective form is an urgent problem both in theoretical and practical aspects of the study, the solution of which is intended to ensure the active mobilization and effective use of the total financial potential of Ukraine, and as a result — its expanded reproduction as well, which would contribute to realization of the internal capacities for stabilization of the national economy. The purpose of the article is disclosing the essence of the effective form of reproducing the total financial potential of the country, analyzing the results of reproducing the total financial potential of Ukraine. It has been proved that the basis for the effective form of reproducing the total financial potential of the country is the volume and flow of resources, which are associated with the «real» economy, affect the dynamics of GDP and define it, i.e. resource and process forms of reproducing the total financial potential of Ukraine (which precede the effective one. The analysis of reproducing the total financial potential of Ukraine has shown that in the analyzed period there was an increase in the financial possibilities of the country, but steady dynamics of reduction of the total financial potential was observed. If we consider the amount of resources involved in production, creating a net value added and GDP, it occurs on a restricted basis. Growth of the total financial potential of Ukraine is connected only with extensive quantitative factors rather than intensive qualitative changes.

  13. On the link between martian total ozone and potential vorticity

    Science.gov (United States)

    Holmes, James A.; Lewis, Stephen R.; Patel, Manish R.

    2017-01-01

    We demonstrate for the first time that total ozone in the martian atmosphere is highly correlated with the dynamical tracer, potential vorticity, under certain conditions. The degree of correlation is investigated using a Mars global circulation model including a photochemical model. Potential vorticity is the quantity of choice to explore the dynamical nature of polar vortices because it contains information on winds and temperature in a single scalar variable. The correlation is found to display a distinct seasonal variation, with a strong positive correlation in both northern and southern winter at poleward latitudes in the northern and southern hemisphere respectively. The identified strong correlation implies variations in polar total ozone during winter are predominantly controlled by dynamical processes in these spatio-temporal regions. The weak correlation in northern and southern summer is due to the dominance of photochemical reactions resulting from extended exposure to sunlight. The total ozone/potential vorticity correlation is slightly weaker in southern winter due to topographical variations and the preference for ozone to accumulate in Hellas basin. In northern winter, total ozone can be used to track the polar vortex edge. The ozone/potential vorticity ratio is calculated for both northern and southern winter on Mars for the first time. Using the strong correlation in total ozone and potential vorticity in northern winter inside the polar vortex, it is shown that potential vorticity can be used as a proxy to deduce the distribution of total ozone where satellites cannot observe for the majority of northern winter. Where total ozone observations are available on the fringes of northern winter at poleward latitudes, the strong relationship of total ozone and potential vorticity implies that total ozone anomalies in the surf zone of the northern polar vortex can potentially be used to determine the origin of potential vorticity filaments.

  14. Approximation of theoretical energy-saving potentials for the petrochemical industry using energy balances for 68 key processes

    International Nuclear Information System (INIS)

    Neelis, Maarten; Patel, Martin; Blok, Kornelis; Haije, Wim; Bach, Pieter

    2007-01-01

    We prepared energy and carbon balances for 68 petrochemical processes in the petrochemical industry for Western Europe, the Netherlands and the world. We analysed the process energy use in relation to the heat effects of the chemical reactions and quantified in this way the sum of all energy inputs into the processes that do not end up in the useful products of the process, but are lost as waste heat to the environment. We showed that both process energy use and heat effects of reaction contribute significantly to the overall energy loss of the processes studied and recommend addressing reaction effects explicitly in energy-efficiency studies. We estimated the energy loss in Western Europe in the year 2000 at 1620 PJ of final energy and 1936 PJ of primary energy, resulting in a total of 127 Mt CO 2 . The losses identified can be regarded as good approximations of the theoretical energy-saving potentials of the processes analysed. The processes with large energy losses in relative (per tonne of product) and absolute (in PJ per year) terms are recommended for more detailed analysis taking into account further thermodynamic, economic, and practical considerations to identify technical and economic energy-saving potentials

  15. District Heating Expansion Potential with Low-Temperature and End-Use Heat Savings

    DEFF Research Database (Denmark)

    Nielsen, Steffen; Grundahl, Lars

    2018-01-01

    District heating has the potential to play a key role in the transition towards a renewable energy system. However, the development towards reduced heat demands threatens the feasibility of district heating. Despite this challenge, opportunity exists in the form of fourth generation district...... heating, which operates at lower temperatures and enables better renewable integration. This article investigates this challenge by examining the district heating potential within three scenarios: The first is a reference scenario with current heat demand and temperatures, the second includes heat demand...... costs. The models are applied using an example case of The Northern Region of Denmark. The article concludes that the district heating potential is highest in the reference scenario. When heat savings are introduced, district heating expansions, in most cases, will not be feasible. Introducing low...

  16. Fossil energy and GHG saving potentials of pig farming in the EU

    Energy Technology Data Exchange (ETDEWEB)

    Nguyen, Thu Lan T.; Hermansen, John E.; Mogensen, Lisbeth [Department of Agroecology and Environment, Aarhus University, Tjele (Denmark)

    2010-05-15

    In Europe, the highly developed livestock industry places a high burden on resource use and environmental quality. This paper examines pig meat production in North-West Europe as a base case and runs different scenarios to investigate how improvements in terms of energy and greenhouse gas (GHG) savings can be feasibly achieved. As shown in the results of the analysis, pig farming in the EU has a high potential to reduce fossil energy use and GHG emissions by taking improvement measures in three aspects: (i) feed use; (2) manure management; and (3) manure utilization. In particular, a combination of improvements in all mentioned aspects offers the highest savings potential of up to 61% fossil energy and 49% GHG emissions. In weighing these three aspects, manure utilization for energy production is found to be the most important factor in reducing fossil energy use and GHG emissions. However, when GHG implications of land use change and land opportunity cost associated with the production of feed crops (e.g. soy meal, cereals) are considered, reducing feed use becomes the main factor in improving GHG performance of EU pork. (author)

  17. Analysis on energy saving potential of integrated supermarket HVAC and refrigeration systems using multiple subcoolers

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Liang [Institute of Refrigeration and Cryogenics, Shanghai Jiaotong University, Shanghai 200240 (China); China R and D Center, Carrier Corporation, No. 3239 Shen Jiang Road, Shanghai 201206 (China); Zhang, Chun-Lu [China R and D Center, Carrier Corporation, No. 3239 Shen Jiang Road, Shanghai 201206 (China)

    2010-02-15

    The paper presents a model-based analysis on the energy saving potential of supermarket HVAC (heating, ventilating, and air-conditioning) and refrigeration systems using multiple subcoolers among the high-temperature HVAC system, the medium-temperature refrigeration system, and the low-temperature refrigeration system. The principle of energy reduction is to have the higher COP (coefficient of performance) system generate more cooling capacity to increase the cooling capacity or reduce the power consumption of the lower COP system. The subcooler could be placed between the medium-temperature and low-temperature systems, between the high-temperature and medium-temperature systems, and between the high-temperature and low-temperature systems. All integration scenarios of adding one, two and three subcoolers have been investigated. The energy saving potential varies with the load ratio between high-, medium- and low-temperature systems, COP of three systems, and the ''on-off'' duty time of HVAC system. The optimal sequence of adding subcoolers is also proposed. (author)

  18. Fossil energy and GHG saving potentials of pig farming in the EU

    International Nuclear Information System (INIS)

    Nguyen, Thu Lan T.; Hermansen, John E.; Mogensen, Lisbeth

    2010-01-01

    In Europe, the highly developed livestock industry places a high burden on resource use and environmental quality. This paper examines pig meat production in North-West Europe as a base case and runs different scenarios to investigate how improvements in terms of energy and greenhouse gas (GHG) savings can be feasibly achieved. As shown in the results of the analysis, pig farming in the EU has a high potential to reduce fossil energy use and GHG emissions by taking improvement measures in three aspects: (i) feed use; (ii) manure management; and (iii) manure utilization. In particular, a combination of improvements in all mentioned aspects offers the highest savings potential of up to 61% fossil energy and 49% GHG emissions. In weighing these three aspects, manure utilization for energy production is found to be the most important factor in reducing fossil energy use and GHG emissions. However, when GHG implications of land use change and land opportunity cost associated with the production of feed crops (e.g. soy meal, cereals) are considered, reducing feed use becomes the main factor in improving GHG performance of EU pork.

  19. Urban passenger transport energy saving and emission reduction potential: A case study for Tianjin, China

    International Nuclear Information System (INIS)

    Peng, Binbin; Du, Huibin; Ma, Shoufeng; Fan, Ying; Broadstock, David C.

    2015-01-01

    Highlights: • Potential to reduce urban passenger transport is projected between 2010 and 2040. • Four scenarios reflecting different policy mixes are considered. • The potential for energy conservation and emission reductions are obtained. • Vehicle population regulation is most effective in energy saving and reducing overall GHG. • Emission standards are the most effective measure to reduce pollutant emissions. - Abstract: With rapid growth of the vehicle population, urban passenger transport in China is largely responsible for increases in energy consumption, greenhouse gas (GHG) emissions, and also atmospheric pollutants (NO x , CO, HC, PM). In this paper, we first develop an urban passenger transport energy saving and emission reduction potential evaluation model using the “Long Range Energy Alternatives Planning (LEAP)” tool; and then take Tianjin city as an empirical case to evaluate the reduction potential of final energy consumption, GHG emissions and pollutants emissions of Tianjin’s urban passenger transport sector between 2010 and 2040 under four scenarios, i.e. BAU (business as usual) scenario, PP (the 12th five-year plan policy) scenario, CP (comprehensive policy) scenario and HP (hybrid policy of PP and CP) scenario. The results show that due to the public transport promotion, energy consumption and CO 2 emissions in 2040 can be reduced by 22% and 22.6% in the PP scenario, compared to BAU. The largest reductions in energy consumption, CO 2 and atmospheric pollutants emissions can be achieved under CP scenario, in which vehicle population regulation is the most effective to be implemented. Emissions standard regulation is the most effective measure to reduce atmospheric pollutant emissions in all the scenarios and green energy promotion is especially effective to reduce NO x and PM

  20. Measuring the impact of efficient household travel decisions on potential travel time savings and accessibility gains

    Energy Technology Data Exchange (ETDEWEB)

    Recker, W.W.; McNally, M.G. [University of California, Irvine (United States). Institute of Transportation Studies, Department of Civil and Environmental Engineering; Chen, C. [Ming-Chuan University, Taiwan (China). Department of Tourism Industry

    2001-07-01

    Using the conceptual framework of time-space geography, this paper incorporates both spatio-temporal constraints and household interaction effects into a meaningful measure of the potential of a household to interact with the built environment. Within this context, personal accessibility is described as a measure of the potential ability of individuals within a household not only to reach activity opportunities, but to do so with sufficient time available for participation in those activities, subject to the spatio-temporal constraints imposed by their daily obligations and transportation supply environment. The incorporation of activity-based concepts in the measurement of accessibility as a product of travel time savings not only explicitly acknowledges a temporal dimension in assessing the potential for spatial interaction but also expands the applicability of accessibility consideration to such real-world policy options as the promotion of ride-sharing and trip chaining behaviors. An empirical application of the model system provides an indication of the potential of activity-based modeling approaches to assess the bounds on achievable improvements in accessibility and travel time based on daily household activity patterns. It also provides an assessment of roles for trip chaining and ride-sharing as potentially effective methods to facilitate transportation policy objectives. (author)

  1. Heating and cooling energy demand in underground buildings : potential for saving in various climates and functions

    NARCIS (Netherlands)

    van Dronkelaar, C.; Costola, D.; Mangkuto, R.A.; Hensen, J.L.M.

    2014-01-01

    Underground buildings are pointed out as alternatives to conventional aboveground buildings for reducing total energy requirements, while alleviating land use and location problems. This paper investigates the potential in reducing the heating and cooling energy demand of underground buildings

  2. Analysis of genuine saving and potential green net national income. Portugal, 1990-2005

    International Nuclear Information System (INIS)

    Mota, Rui Pedro; Domingos, Tiago; Martins, Victor

    2010-01-01

    The context of this paper is the measurement of welfare and weak sustainability (defined as non-declining utility) in dynamic economies, i.e., comprehensive or green accounting. We estimate green net national income (GNNI) and genuine saving (GS) for Portugal, for the years 1990 to 2005, accounting for the disamenity of air pollution emissions, the depreciation of commercial forests and the value of time, discussing the implications of the assumptions underlying the inclusion of these terms in the green accounting model. The influence of short-run cycles is analyzed by estimating GNNI excluding business cycles. Our results suggest that business cycles affect the sustainability message of GNNI. We find that potential GNNI is growing and GS is positive in the analyzed period, thereby not indicating a weak sustainability problem in Portugal, although both depict a trend towards unsustainability. Excluding technological progress there is a contradiction in the sustainability message of GNNI and GS. (author)

  3. Energy Savings Potential and RD&D Opportunities for Non-Vapor-Compression HVAC Technologies

    Energy Technology Data Exchange (ETDEWEB)

    none,

    2014-03-01

    While vapor-compression technologies have served heating, ventilation, and air-conditioning (HVAC) needs very effectively, and have been the dominant HVAC technology for close to 100 years, the conventional refrigerants used in vapor-compression equipment contribute to global climate change when released to the atmosphere. This Building Technologies Office report: --Identifies alternatives to vapor-compression technology in residential and commercial HVAC applications --Characterizes these technologies based on their technical energy savings potential, development status, non-energy benefits, and other factors affecting end-user acceptance and their ability to compete with conventional vapor-compression systems --Makes specific research, development, and deployment (RD&D) recommendations to support further development of these technologies, should DOE choose to support non-vapor-compression technology further.

  4. Analysis of genuine saving and potential green net national income. Portugal, 1990-2005

    Energy Technology Data Exchange (ETDEWEB)

    Mota, Rui Pedro; Domingos, Tiago [Environment and Energy Section, DEM, Instituto Superior Tecnico (Portugal); Martins, Victor [Department of Economics, Instituto Superior de Economia e Gestao (Portugal)

    2010-08-15

    The context of this paper is the measurement of welfare and weak sustainability (defined as non-declining utility) in dynamic economies, i.e., comprehensive or green accounting. We estimate green net national income (GNNI) and genuine saving (GS) for Portugal, for the years 1990 to 2005, accounting for the disamenity of air pollution emissions, the depreciation of commercial forests and the value of time, discussing the implications of the assumptions underlying the inclusion of these terms in the green accounting model. The influence of short-run cycles is analyzed by estimating GNNI excluding business cycles. Our results suggest that business cycles affect the sustainability message of GNNI. We find that potential GNNI is growing and GS is positive in the analyzed period, thereby not indicating a weak sustainability problem in Portugal, although both depict a trend towards unsustainability. Excluding technological progress there is a contradiction in the sustainability message of GNNI and GS. (author)

  5. Health economic modeling of the potential cost saving effects of Neurally Adjusted Ventilator Assist.

    Science.gov (United States)

    Hjelmgren, Jonas; Bruce Wirta, Sara; Huetson, Pernilla; Myrén, Karl-Johan; Göthberg, Sylvia

    2016-02-01

    Asynchrony between patient and ventilator breaths is associated with increased duration of mechanical ventilation (MV). Neurally Adjusted Ventilatory Assist (NAVA) controls MV through an esophageal reading of diaphragm electrical activity via a nasogastric tube mounted with electrode rings. NAVA has been shown to decrease asynchrony in comparison to pressure support ventilation (PSV). The objective of this study was to conduct a health economic evaluation of NAVA compared with PSV. We developed a model based on an indirect link between improved synchrony with NAVA versus PSV and fewer days spent on MV in synchronous patients. Unit costs for MV were obtained from the Swedish intensive care unit register, and used in the model along with NAVA-specific costs. The importance of each parameter (proportion of asynchronous patients, costs, and average MV duration) for the overall results was evaluated through sensitivity analyses. Base case results showed that 21% of patients ventilated with NAVA were asynchronous versus 52% of patients receiving PSV. This equals an absolute difference of 31% and an average of 1.7 days less on MV and a total cost saving of US$7886 (including NAVA catheter costs). A breakeven analysis suggested that NAVA was cost effective compared with PSV given an absolute difference in the proportion of asynchronous patients greater than 2.5% (49.5% versus 52% asynchronous patients with NAVA and PSV, respectively). The base case results were stable to changes in parameters, such as difference in asynchrony, duration of ventilation and daily intensive care unit costs. This study showed economically favorable results for NAVA versus PSV. Our results show that only a minor decrease in the proportion of asynchronous patients with NAVA is needed for investments to pay off and generate savings. Future studies need to confirm this result by directly relating improved synchrony to the number of days on MV. © The Author(s), 2015.

  6. Historical changes and recent energy saving potential of residential heating in Korea

    International Nuclear Information System (INIS)

    Yeo, M.-S.; Yang, I.-H.; Kim, K.-W.

    2003-01-01

    The residential heating method in Korea underwent various phases of development to reach the current system. The first phase was the traditional Ondol (the traditional under-floor heating system in Korea), where the floor was heated by the circulation of hot gas produced by a fire furnace (before the 1950s). The second phase involved the use of the modified anthracite coal Ondol, for which the fire furnace was modified for briquette use (from the early 1950s to the late 1970s). The third phase involved the use of hot water radiant floor heating with embedded tubes (from the late 1970s). This paper presents insights into the problem of current residential heating in Korea and the general aspects of heating energy savings by tracing the history of residential heating in Korea and analyzing related data. The results show that modern apartment buildings with hot water radiant floor heating (the third phase) yield less heat loss due to the tighter envelope, but also yield higher energy consumption than the traditional Ondol heating housing (the first phase). Because of an inefficient system and lack of thermal insulation of the traditional Ondol heating housing, Ondol heating was used to heat occupants sitting directly on the floor, keeping lower room temperature and higher floor surface temperature. So the range of comfortable floor temperature for Korean people is higher and this unique comfort sense is related to energy consumption in modern apartment housing. As a result, several energy saving methods were found such as reducing the total floor heating area or zoning the floor area, receiving continuous heat supply, and installing a delicate control system and metering devices. (author)

  7. Characterization of the household electricity consumption in the EU, potential energy savings and specific policy recommendations

    Energy Technology Data Exchange (ETDEWEB)

    Fonseca, Paula; Almeida, Anibal de (ISR-Univ. of Coimbra, Dep. Electrical Engineering (Portugal)). e-mail: pfonseca@isr.uc.pt; Feilberg, Nicolai (SINTEF Energiforskning AS (Norway)); Markogiannakis, George (Centre for Renewable Energy Sources - CRES (Greece)); Kofod, Casper (Energy piano (Denmark))

    2009-07-01

    Although significant improvements in energy efficiency have been achieved in home appliances and lighting, the electricity consumption in the average EU-27 household has been increasing by about 2% per year during the past 10 years. Some reasons for such increase are associated with an increased degree of basic comfort and level of amenities (particularly in the new EU member countries) and also with the widespread utilization of relatively new types of loads whose penetration and use has experienced a very significant growth in recent years. With the objective of contributing to an increased understanding of the energy consumption in the EU-27 households for the different types of equipment including the consumers' behaviour and comfort levels, and to identify demand trends, a large energy monitoring campaign, co-funded by the IEE programme, was carried out in 12 countries, accompanied by a lifestyle consumer survey. From the measurements carried out it can be concluded that IT and entertainment loads, including standby, are a key contributor to the power demand. In basically all types of loads there is wide range of performance levels, including new emerging technologies, in the models available in the market. Available technology, associated with responsible consumer behaviour, can reduce wasteful consumption. The potential electricity savings that exist in the residential sector in Europe, and that can already be implemented by existing means, like the use of BAT (best available technology) efficient appliances or the elimination/mitigation of standby consumption, can reach up to 48% savings. Specific policy recommendations to promote market transformation and behavioural changes in the equipment selection and operation have been identified.

  8. National potential of saving of electricity in domestic refrigeration; Potencial nacional de ahorro de electricidad en refrigeracion domestica

    Energy Technology Data Exchange (ETDEWEB)

    Arroyo C, Fernando [Universidad Nacional Autonoma de Mexico (Mexico); Ambriz G, Juan Jose; Romero P, Hernando [Universidad Autonoma Metropolitana, (Mexico)

    2003-07-01

    In the present paper the evaluation of the potential of saving of electrical energy in Mexico is presented, by means of the substitution of old refrigerators of low efficiency by modern high efficiency ones. This potential is very ample, since the replacement of the old models by new follows a very slow curve, if the economic difficulties of the Mexican families are considered and that, on the other hand, the technology of the domestic refrigerators is so reliable that they have a very long life and they are not easily rejected. In field work have been found refrigerators operating with ages of more than 30 years and still 40. In Mexico, it is estimated that the refrigeration is responsible for around 29% of the of electricity consumption in homes settled in tempered climate and of 14 % in those of warm climate in which air conditioning is used. The proposal of this work is the organization of a governmental program of accelerated substitution of refrigerators that helps to acquire an efficient refrigerator and to reject the old ones. The results indicate that if a total renovation of the park of domestic refrigerators is made, the saving of electrical energy would reach the 5.2 TWh/a which represents the 44.5% of the total consumption of 11.7 TWh in a year. [Spanish] En el presente trabajo se presenta la evaluacion del potencial de ahorro de energia electrica en Mexico, mediante la substitucion de refrigeradores antiguos de baja eficiencia por modernos de alta eficiencia. Este potencial es muy amplio, ya que el reemplazo de los modelos viejos por nuevos sigue una curva muy lenta, si se consideran las dificultades economicas de las familias mexicanas y que, por otro lado, la tecnologia de los refrigeradores domesticos es tan confiable que tienen una vida muy larga y no se desechan facilmente. En trabajos de campo se han encontrado refrigeradores operando con edades de mas de 30 anos y aun 40. En Mexico, se estima que la refrigeracion es responsable de alrededor del

  9. Reasonable potential for GHG savings by anaerobic biomethane in Germany and UK derived from economic and ecological analyses

    International Nuclear Information System (INIS)

    Horschig, Thomas; Adams, Paul W.R.; Röder, Mirjam; Thornley, Patricia; Thrän, Daniela

    2016-01-01

    Highlights: • Biomethane market potential estimation through biogas market analyses. • Country comparison of Germany and the UK in terms of bioenergy. • Assessment of possible greenhouse gas emission savings by biomethane. • Role of biomethane to achieve greenhouse gas reduction goals in Germany and the UK was investigated. - Abstract: This study introduces a new approach to estimate biomethane market potential by analysing biogas markets and their relative environmental and economic advantages. This potential is then combined with greenhouse gas emission values for different feedstock shares (farm-fed and waste-fed systems) and different application share to determine the possible contribution of biomethane to national greenhouse gas emission saving goals. Markets that are considered are Germany and the UK being the biggest emitters of CO_2_e_q in the European Union. The current use was compared with the scenarios (i) market projection, derived from literature study and (ii) reasonable potential, derived from environmental and economic calculations. The current market status is presented to show the past market development until the present date and associated greenhouse gas savings. Additionally the potential of biomethane to contribute to greenhouse gas emission savings is extensively described. Results indicate that the share of application in Germany is more environmental beneficial than the one in the UK achieving higher greenhouse gas savings at comparable feed-in level. In contrast, the UK has a higher share of waste-fed systems to produce biomethane. The use of biomethane in CHP plants achieves the highest GHG emission savings and if organic waste is used as feedstock the possible savings are even higher. With an increase of biomethane used in CHP plants and a decrease of biomethane used for direct heating the savings in the UK could increase up to 52%. Current savings of 2446 kt CO_2_e_q (Germany) and 606 kt CO_2_e_q (UK) can be extended to 4483

  10. Potentials for energy saving and CO2 reduction in Baden-Wuerttemberg. Status report

    International Nuclear Information System (INIS)

    Weimer, W.; Luenstroth, U.

    1993-01-01

    In order to protect the climate the Administration of the state of Baden-Wuerttemberg aims at cutting energy-related CO 2 -emissions by 30% by the year 2005. This study analyses the potentials of energy consumption and CO 2 -reduction in the state of Baden-Wuerttemberg in the framework of an evaluation of literature. As special emphasis is put on technical steps such as an increase in efficiency with respect to the generation and consumption of energy as well as on the substitution of fossil energy sources by regenerative techniques of energy generation. In order to obtain considerable potentials of energy-saving a moderate increase in energy prices as well as several actions to reduce impediments are required . However, an achievement of those goals by the year 2005 is only partly possible, because of the time required. The evaluation of literature serves as a preparation of the comprehensive project Klimavertraegliche Energieversorgung in Baden-Wuerttemberg (greenhouse-gas-reduced energy supply in Baden-Wuerttemberg) of the Center of Technology Assessment in Baden-Wuerttemberg. (orig.) [de

  11. A protocol for sustained reduction of Total Parenteral Nutrition and cost savings by improvement of nutritional care in hospitals.

    Science.gov (United States)

    van Schaik, Rian; Van den Abeele, Kurt; Melsens, Glenn; Schepens, Peter; Lanssens, Truus; Vlaemynck, Bernadette; Devisch, Maria; Niewold, Theo A

    2016-10-01

    Malnutrition and the use of Total Parenteral Nutrition (TPN) contribute considerably to hospital costs. Recently, we reported on the introduction of malnutrition screening and monitoring of TPN use in our hospital, which resulted in a large (40%) reduction in TPN and improved quality of nutritional care in two years (2011/12). Here, we aimed to assure continuation of improved care by developing a detailed malnutrition screening and TPN use protocol involving instruction tools for hospital staff, while monitoring the results in the following two years (2013/14). A TPN decision tree for follow up of TPN in patients and a TP-EN instruction card for caregivers was introduced, showing TPN/EN introduction schedules based on the energy needs of patients according to EB guidelines, also addressing the risk of refeeding syndrome. TPN patients were monitored by dietitians and TPN usage and costs were presented to the (medical) staff. Screening and treatment of malnourished patients by dietitians is simultaneously ongoing. In 2014 48% of patients, hospitalized for at least 48 h, were screened on malnutrition, 17% of them were diagnosed at risk, 7.9% malnourished and treated by dietitians. TPN usage dropped by 53% and cost savings of 51% were obtained due to 50% decrease of TPN users in 2014 versus 2010. TPN over EN ratio dropped from 2.4 in 2010 to 1.2 in 2014. Sustained improvement of nutritional care and reduction of TPN usage and costs is possible by introduction of procedures embedded in the existing structures. Copyright © 2016 European Society for Clinical Nutrition and Metabolism. Published by Elsevier Ltd. All rights reserved.

  12. Energy consumption and CO2 emissions of industrial process technologies. Saving potentials, barriers and instruments

    International Nuclear Information System (INIS)

    Fleiter, Tobias; Schlomann, Barbara; Eichhammer, Wolfgang

    2013-01-01

    Which contribution can the increase of energy efficiency achieve in the industry energy for the energy transition in Germany? To answer this question a model-based analysis of existing energy efficiency potentials of the energy-intensive industries is performed, which account for about 70% of the total energy demand of the industry. Based on this industry for each sector are instruments proposed for the implementation of the calculated potential and to overcome the existing barriers. [de

  13. Rotavirus diarrhea disease burden in Peru: the need for a rotavirus vaccine and its potential cost savings.

    Science.gov (United States)

    Ehrenkranz, P; Lanata, C F; Penny, M E; Salazar-Lindo, E; Glass, R I

    2001-10-01

    To assess the disease burden of rotavirus diarrhea in Peru as well the need for and the potential cost savings with a rotavirus vaccine in that country. To assess the burden of rotavirus diarrhea in Peru, we reviewed published and unpublished reports where rotavirus was sought as the etiologic agent of diarrhea in children. Rotavirus detection rates obtained from these studies were combined with diarrhea incidence rates from a number of national surveys in order to estimate both the burden of rotavirus diarrhea in the country and its associated medical costs. Rotavirus is a significant cause of morbidity and mortality in Peruvian children. In their first 5 years of life, an estimated 1 in 1.6 children will experience an episode of rotavirus diarrhea, 1 in 9.4 will seek medical care, 1 in 19.7 will require hospitalization, and 1 in 375 will die of the disease. Per year, this represents approximately 384,000 cases, 64,000 clinic visits, 30,000 hospitalizations, and 1,600 deaths. The annual cost of medical care alone for these children is approximately US$ 2.6 million--and that does not take into account the indirect or societal costs of the illness and the deaths. Rotavirus immunization provides the prospect of decreasing the morbidity and mortality from diarrhea in Peru, but a vaccine regimen would have to be relatively inexpensive, a few dollars or less per child. Future cost-effectiveness analyses should explore the total costs (medical as well as indirect or societal) associated with rotavirus diarrhea. Newly licensed vaccines should be tested according to both their ability to avert deaths and their efficacy with fewer than three doses. All three of these factors could increase the cost savings associated with a rotavirus vaccine.

  14. Rotavirus diarrhea disease burden in Peru: the need for a rotavirus vaccine and its potential cost savings

    Directory of Open Access Journals (Sweden)

    Peter Ehrenkranz

    2001-10-01

    Full Text Available Objective. To assess the disease burden of rotavirus diarrhea in Peru as well the need for and the potential cost savings with a rotavirus vaccine in that country. Methods. To assess the burden of rotavirus diarrhea in Peru, we reviewed published and unpublished reports where rotavirus was sought as the etiologic agent of diarrhea in children. Rotavirus detection rates obtained from these studies were combined with diarrhea incidence rates from a number of national surveys in order to estimate both the burden of rotavirus diarrhea in the country and its associated medical costs. Results. Rotavirus is a significant cause of morbidity and mortality in Peruvian children. In their first 5 years of life, an estimated 1 in 1.6 children will experience an episode of rotavirus diarrhea, 1 in 9.4 will seek medical care, 1 in 19.7 will require hospitalization, and 1 in 375 will die of the disease. Per year, this represents approximately 384 000 cases, 64 000 clinic visits, 30 000 hospitalizations, and 1 600 deaths. The annual cost of medical care alone for these children is approximately US$ 2.6 million--and that does not take into account the indirect or societal costs of the illness and the deaths. Conclusions. Rotavirus immunization provides the prospect of decreasing the morbidity and mortality from diarrhea in Peru, but a vaccine regimen would have to be relatively inexpensive, a few dollars or less per child. Future cost-effectiveness analyses should explore the total costs (medical as well as indirect or societal associated with rotavirus diarrhea. Newly licensed vaccines should be tested according to both their ability to avert deaths and their efficacy with fewer than three doses. All three of these factors could increase the cost savings associated with a rotavirus vaccine.

  15. The potential for energy savings when reducing the water consumption in a kraft pulp mill

    Energy Technology Data Exchange (ETDEWEB)

    Wising, Ulrika; Berntsson, Thore [Chalmers Univ. of Technology, Goeteborg (Sweden). Dept. of Chemical Engineering and Environmental Science; Stuart, Paul [Ecole Polytechnique, Montreal (Canada). Dept. of Chemical Engineering

    2004-05-01

    In this paper an existing pulp and paper mill has been studied in a systematic way regarding the reduction of water consumption, and the resulting increased potential for energy integration. It has been found that when the mill's hot water consumption is decreased, the live steam demand for the mill also decreases. Also when decreasing the hot water consumption, the quantity and temperature of available excess heat increases. This excess heat can be used for evaporation, thereby reducing the live steam demand further by up to 1.5 GJ/t. A pinch analysis was performed at an existing mill and it was found that if pinch violations are removed, the hot water consumption is not an important factor any more. Removing all the pinch violations and using the remaining excess heat for evaporation yields a significantly larger energy savings for the mill (4.0 GJ/t). From an economic optimum perspective it is probably most profitable to do a combination of reducing water consumption, removing pinch violations, and use the remaining excess heat for evaporation.

  16. Electrical heating tapes, their use, energy consumption and energy savings potential

    International Nuclear Information System (INIS)

    Nipkow, J.; Lingenhel, S.

    2002-01-01

    Heating cables require about 0.6% of Swiss electricity consumption, approximately as much as all TV-sets. Most important applications are domestic hot water distribution tubing, frost protection (tubing, gutters) and industrial tubing, each requiring about 1/3. For over 10 years, self-regulating technology is standard for heating cables and offers pre-defined maintenance temperatures. To minimize electricity consumption, in most applications additional control devices (timer, temperature-/ power control) are necessary. The study could not give a general answer to whether domestic hot water distribution systems should be heated by heating cables or circulation systems. The best solution depends on the specific building circumstances. Conclusions of the technical and market analysis say that measures in different fields can transfer the saving potentials into practice: architects and designers of sanitary and electrical installations should be informed by articles in specialized magazines: the goal is either to avoid the use of heating cables or to minimize their electricity consumption, training of plumbers and electricians should treat the efficient use of heating cables. An instruction leaflet is to be created. Building owners and operators should be informed by their specialized magazines about problems with heating cables. (author)

  17. Climate protection with rapid payback. Energy and CO2 savings potential of industrial insulation in EU27

    Energy Technology Data Exchange (ETDEWEB)

    Neelis, M.; Blinde, P.; Overgaag, M.; Deng, Y. [Ecofys Netherlands, Utrecht (Netherlands)

    2012-06-15

    This study aims to answer the following four questions: (1) What is the energy savings and CO2 emissions mitigation potential resulting from insulating currently uninsulated parts and from better maintenance of insulation systems?; (2) What are the energy savings and CO2 mitigation potential from improving current insulation to cost-effective levels? Cost-effective insulation in this study is defined as the insulation that minimises the sum of the costs of heat loss and the costs of insulation; (3) What is the energy savings and CO2 mitigation potential from improving current insulation beyond cost-effective levels to even more energy-efficient levels? Energy-efficient insulation in this study is defined as the insulation at which the sum of the costs of heat loss and the annualised insulation investments are equal to the costs of typical current insulation while offering an additional energy savings and CO2 mitigation potential; and (4) How can these potentials best be realised? This study investigates savings potentials from improved insulation in EU industry and the power sector under realistic market conditions. Nuclear power plants and power production by renewable sources were left outside the scope of this study as well as insulations of cold applications. Case studies of insulation projects have been used to compare energy loss and investments related to different levels of insulation. The analysis was performed for three temperature levels: <100C; 100-300C and >300C. Results at the level of the case studies were extrapolated to European level using data on current energy use. Other assumptions have been made where needed on the basis of literature and expert input. All potentials are based on a 9% discount rate, an average insulation lifetime of 15 years and a 2-3% per year increase of the price of energy net of inflation.

  18. Energy Saving Potentials of Phase Change Materials Applied to Lightweight Building Envelopes

    Directory of Open Access Journals (Sweden)

    Yoon-Bok Seong

    2013-10-01

    Full Text Available Phase change materials (PCMs have been considered as an innovative technology that can reduce the peak loads and heating, ventilating and air conditioning (HVAC energy consumption in buildings. Basically they are substances capable of storing or releasing thermal energy as latent heat. Because the amount of latent heat absorbed or released is much larger than the sensible heat, the application of PCMs in buildings has significant potential to reduce energy consumption. However, because each PCM has its own phase change temperature, which is the temperature at which latent heat is absorbed or released, it is important to use an appropriate PCM for the purpose of building envelope design. Therefore, this paper aims to investigate the energy saving potentials in buildings when various PCMs with different phase change temperatures are applied to a lightweight building envelope by analyzing the thermal load characteristics. As results, the annual heating load increased at every phase change temperature, but the peak heating load decreased by 3.19% with heptadecane (phase change temperature 21 °C, and the lowest indoor temperature increased by 0.86 °C with heptadecane (phase change temperature 21 °C. The annual cooling load decreased by 1.05% with dodecanol (phase change temperature 24 °C, the peak cooling load decreased by 1.30% with octadecane (phase change temperature 29 °C, and the highest indoor temperature dropped by 0.50 °C with octadecane (phase change temperature 29 °C. When the night ventilation was applied to the building HVAC system for better passive cooling performance, the annual cooling load decreased by 9.28% with dodecanol (phase change temperature 24 °C, the peak load decreased by 11.33% with octadecane (phase change temperature 29 °C, and the highest indoor temperature dropped by 0.85 °C with octadecane (phase change temperature 29 °C.

  19. Energy savings potential in China's industrial sector: From the perspectives of factor price distortion and allocative inefficiency

    International Nuclear Information System (INIS)

    Ouyang, Xiaoling; Sun, Chuanwang

    2015-01-01

    China's industrial energy consumption accounted for 70.82% of national and 14.12% of world energy usage in 2011. In the context of energy scarcity and environmental pollution, the industrial sector in China faces unsustainable growth problems. By adopting the stochastic frontier analysis (SFA) framework, this paper analyzes the factor allocative efficiency of China's industrial sector, and estimates the energy savings potential from the perspective of allocative inefficiency. This paper focuses on three issues. The first is examining the factor allocative inefficiency of China's industrial sector. The second is measuring factor price distortion by the shadow price model. The third is estimating the energy savings potential in China's industrial sector during 2001–2009. Major conclusions are thus drawn. First, factor prices of capital, labor and energy are distorted in China due to government regulations. Moreover, energy price is relatively low compared to capital price, while is relatively high compared to labor price. Second, the industry-wide energy savings potential resulted from energy allocative inefficiency was about 9.71% during 2001–2009. The downward trend of energy savings potential implies the increasing energy allocative efficiency in China's industrial sector. Third, a transparent and reasonable pricing mechanism is conducive to improving energy allocative efficiency. - Highlights: • We measure energy savings potential resulted from allocative inefficiency in China's industrial sector. • Allocative inefficiency is explained based on the theoretical and empirical models. • Factor prices of capital, labor and energy are distorted because of government regulations. • Energy pricing reform is conducive to improving energy allocative efficiency

  20. Model for Determining Geographical Distribution of Heat Saving Potentials in Danish Building Stock

    Directory of Open Access Journals (Sweden)

    Stefan Petrovic

    2014-02-01

    Full Text Available Since the global oil crisis in the 1970s, Denmark has followed a path towards energy independency by continuously improving its energy efficiency and energy conservation. Energy efficiency was mainly tackled by introducing a high number of combined heat and power plants in the system, while energy conservation was predominantly approached by implementing heat saving measures. Today, with the goal of 100% renewable energy within the power and heat sector by the year 2035, reductions in energy demand for space heating and the preparation of domestic hot water remain at the top of the agenda in Denmark. A highly detailed model for determining heat demand, possible heat savings and associated costs in the Danish building stock is presented. Both scheduled and energy-saving renovations until year 2030 have been analyzed. The highly detailed GIS-based heat atlas for Denmark is used as a container for storing data about physical properties for 2.5 million buildings in Denmark. Consequently, the results of the analysis can be represented on a single building level. Under the assumption that buildings with the most profitable heat savings are renovated first, the consequences of heat savings for the economy and energy system have been quantified and geographically referenced. The possibilities for further improvements of the model and the application to other geographical regions have been discussed.

  1. Peripherally Inserted Central Catheters (PICCs) and Potential Cost Savings and Shortened Bed Stays In an Acute Hospital Setting.

    LENUS (Irish Health Repository)

    O’Brien, C

    2018-01-01

    Peripheral inserted central catheters (PICCs) have increasingly become the mainstay of patients requiring prolonged treatment with antibiotics, transfusions, oncologic IV therapy and total parental nutrition. They may also be used in delivering a number of other medications to patients. In recent years, bed occupancy rates have become hugely pressurized in many hospitals and any potential solutions to free up beds is welcome. Recent introductions of doctor or nurse led intravenous (IV) outpatient based treatment teams has been having a direct effect on early discharge of patients and in some cases avoiding admission completely. The ability to deliver outpatient intravenous treatment is facilitated by the placement of PICCs allowing safe and targeted treatment of patients over a prolonged period of time. We carried out a retrospective study of 2,404 patients referred for PICCs from 2009 to 2015 in a university teaching hospital. There was an exponential increase in the number of PICCs requested from 2011 to 2015 with a 64% increase from 2012 to 2013. The clear increase in demand for PICCs in our institution is directly linked to the advent of outpatient intravenous antibiotic services. In this paper, we assess the impact that the use of PICCs combined with intravenous outpatient treatment may have on cost and hospital bed demand. We advocate that a more widespread implementation of this service throughout Ireland may result in significant cost savings as well as decreasing the number of patients on hospital trollies.

  2. Use of reference buildings to assess the energy saving potentials of the residential building stock: The experience of TABULA project

    International Nuclear Information System (INIS)

    Ballarini, Ilaria; Corgnati, Stefano Paolo; Corrado, Vincenzo

    2014-01-01

    Retrofit actions applied to the existent building stock aim at increasing the energy performance, considering the optimal trade-off between energy savings and costs, according to the Directive 2010/31/EU. To select effective refurbishment measures and to quantify the energy saving potentials of the existent building stock, the analysis should be performed on “reference buildings”. This article presents a methodology for the identification of reference buildings, according to the IEE-TABULA project (2009–12) aimed at creating a harmonised structure for “European Building Typologies”. Among the possible applications of the building typology, this work focuses on the potentialities of energy savings and CO 2 emission reductions for the European residential building stock. In particular, the Italian approach to model the energy balance of a subset of the national building stock is described; the results show the enormous potentialities of energy savings even with basic energy retrofit actions. Cost analyses were not in the scope of the project, but the results of this study are the basis for further investigations aimed at assessing the cost effectiveness of sets of measures. In this regard, the TABULA building-types are being applied by the Italian government for calculating cost-optimal levels of energy performance, complying with the Directive 2010/31/EU objectives. - Highlights: • European building stocks need retrofit actions to improve the energy performance. • Necessity to define “reference buildings” in order to perform cost-optimal analyses. • Definition of a National “Building Typology” according to IEE-TABULA project. • Methodology to identify reference buildings for assessing energy saving potentials

  3. Model for Determining Geographical Distribution of Heat Saving Potentials in Danish Building Stock

    DEFF Research Database (Denmark)

    Petrovic, Stefan; Karlsson, Kenneth Bernard

    2014-01-01

    Since the global oil crisis in the 1970s, Denmark has followed a path towards energy independency by continuously improving its energy efficiency and energy conservation. Energy efficiency was mainly tackled by introducing a high number of combined heat and power plants in the system, while energy...... conservation was predominantly approached by implementing heat saving measures. Today, with the goal of 100% renewable energy within the power and heat sector by the year 2035, reductions in energy demand for space heating and the preparation of domestic hot water remain at the top of the agenda in Denmark....... A highly detailed model for determining heat demand, possible heat savings and associated costs in the Danish building stock is presented. Both scheduled and energy-saving renovations until year 2030 have been analyzed. The highly detailed GIS-based heat atlas for Denmark is used as a container for storing...

  4. Monetary or environmental appeals for saving electricity? –Potentials for spillover on low carbon policy acceptability

    International Nuclear Information System (INIS)

    Steinhorst, Julia; Matthies, Ellen

    2016-01-01

    The acceptability of low carbon policies is an important precondition for energy system transitions, such as the German Energiewende. This long-term experimental study examines the potential for behavioural spillover on the acceptability of low carbon policies, caused by a framed intervention to promote electricity saving behaviour. Clients of a German energy provider were randomly assigned to continuously receive electricity saving tips with either monetary framing (saving potential in €) or environmental framing (saving potential in CO_2). The control group did not receive any information. In two follow-up surveys, four (N=333) and nine months (N=258) later, participants rated the acceptability of several low carbon policies. A pre-survey assessed the personal ecological norm for saving electricity. Participants with strong personal ecological norms reported generally higher policy acceptability. After environmental framing they also indicated higher acceptability compared to the monetary framing or control group. These results indicate that information campaigns should be designed carefully in order to promote positive spillover effects. Environmental framing of private-sphere behaviour can increase the disposition for further pro-environmental behaviour in the public sphere, e.g. policy acceptability. When appealing to monetary benefits in pro-environmental behaviour, there is a risk of inhibiting positive spillover effects. - Highlights: •Policy acceptability may be influenced by type of framing and individual factors. •We examined long-term spillover effects in association with type of framing. •Framing (environmental vs. monetary) interacts with personal ecological norms. •For strong personal ecological norms, environmental framing increases acceptability. •Also, strong personal ecological norms increase low carbon policy acceptability.

  5. Overview of direct air free cooling and thermal energy storage potential energy savings in data centres

    International Nuclear Information System (INIS)

    Oró, Eduard; Depoorter, Victor; Pflugradt, Noah; Salom, Jaume

    2015-01-01

    In the last years the total energy demand of data centres has experienced a dramatic increase which is expected to continue. This is why data centres industry and researchers are working on implementing energy efficiency measures and integrating renewable energy to overcome energy dependence and to reduce operational costs and CO 2 emissions. The cooling system of these unique infrastructures can account for 40% of the total energy consumption. To reduce the energy consumption, free cooling strategies are used more and more, but so far there has been little research about the potential of thermal energy storage (TES) solutions to match energy demand and energy availability. Hence, this work intends to provide an overview of the potential of the integration of direct air free cooling strategy and TES systems into data centres located at different European locations. For each location, the benefit of using direct air free cooling is evaluated energetically and economically for a data centre of 1250 kW. The use of direct air free cooling is shown to be feasible. This does not apply the TES systems by itself. But when using TES in combination with an off-peak electricity tariff the operational cooling cost can be drastically reduced. - Highlights: • The total annual hours for direct air free cooling in data centres are calculated. • The potential of TES integration in data centres is evaluated. • The implementation of TES to store the ambient air cold is not recommended. • TES is feasible if combined with redundant chillers and off-peak electricity price. • The cooling electricity cost is being reduced up to 51%, depending on the location

  6. Potential savings of harmonising hospital and community formularies for chronic disease medications initiated in hospital.

    Directory of Open Access Journals (Sweden)

    Lauren Lapointe-Shaw

    Full Text Available Hospitals in Canada manage their formularies independently, yet many inpatients are discharged on medications which will be purchased through publicly-funded programs. We sought to determine how much public money could be saved on chronic medications if hospitals promoted the initiation of agents with the lowest outpatient formulary prices.We used administrative databases for the province of Ontario to identify patients initiated on a proton pump inhibitor (PPI, angiotensin-converting enzyme (ACE inhibitor or angiotensin receptor blocker (ARB following hospital admission from April 1(st 2008-March 31(st 2009. We assessed the cost to the Ontario Drug Benefit Program (ODB over the year following initiation and determined the cost savings if prescriptions were substituted with the least expensive agent in each class.The cost for filling all PPI, ACE inhibitor and ARB prescriptions was $ 2.48 million, $968 thousand and $325 thousand respectively. Substituting the least expensive agent could have saved $1.16 million (47% for PPIs, $162 thousand (17% for ACE inhibitors and $14 thousand (4% for ARBs over the year following discharge.In a setting where outpatient prescriptions are publicly funded, harmonising outpatient formularies with inpatient therapeutic substitution resulted in modest cost savings and may be one way to control rising pharmaceutical costs.

  7. Canadian Potential Healthcare and Societal Cost Savings from Consumption of Pulses: A Cost-Of-Illness Analysis

    Directory of Open Access Journals (Sweden)

    Mohammad M. H. Abdullah

    2017-07-01

    Full Text Available Consumption of dietary pulses, including beans, peas and lentils, is recommended by health authorities across jurisdictions for their nutritional value and effectiveness in helping to prevent and manage major diet-related illnesses of significant socioeconomic burden. The aim of this study was to estimate the potential annual healthcare and societal cost savings relevant to rates of reduction in complications from type 2 diabetes (T2D and incidence of cardiovascular disease (CVD following a low glycemic index (GI or high fiber diet that includes pulses, or 100 g/day pulse intake in Canada, respectively. A four-step cost-of-illness analysis was conducted to: (1 estimate the proportions of individuals who are likely to consume pulses; (2 evaluate the reductions in established risk factors for T2D and CVD; (3 assess the percent reduction in incidences or complications of the diseases of interest; and (4 calculate the potential annual savings in relevant healthcare and related costs. A low GI or high fiber diet that includes pulses and 100 g/day pulse intake were shown to potentially yield Can$6.2 (95% CI $2.6–$9.9 to Can$62.4 (95% CI $26–$98.8 and Can$31.6 (95% CI $11.1–$52 to Can$315.5 (95% CI $110.6–$520.4 million in savings on annual healthcare and related costs of T2D and CVD, respectively. Specific provincial/territorial analyses suggested annual T2D and CVD related cost savings that ranged from up to Can$0.2 million in some provinces to up to Can$135 million in others. In conclusion, with regular consumption of pulse crops, there is a potential opportunity to facilitate T2D and CVD related socioeconomic cost savings that could be applied to Canadian healthcare or re-assigned to other priority domains. Whether these potential cost savings will be offset by other healthcare costs associated with longevity and diseases of the elderly is to be investigated over the long term.

  8. Analysis of energy-saving potential in residential buildings in Xiamen City and its policy implications for southern China

    Science.gov (United States)

    Guo, Fei

    The buildings sector is the largest energy-consuming sector in the world. Residential buildings consume about three-quarters of the final energy in the buildings sector. Promoting residential energy savings is in consequence critical for addressing many energy-use-related environmental challenges, such as climate change and air pollution. Given China's robust economic growth and fast urbanization, it is now a critical time to develop policy interventions on residential energy use in the nation. With this as a background, this dissertation explores effective policy intervention opportunities in southern China through analyzing the residential energy-saving potential, using the city of Xiamen as a case study. Four types of residential energy-saving potential are analyzed: technical potential, economic potential, maximum achievable potential (MAP), and possible achievable potential (PAP). Of these, the first two types are characterized as static theoretical evaluation, while the last two represent dynamic evaluation within a certain time horizon. The achievable potential analyses are rarely seen in existing literature. The analytical results reveal that there exists a significant technical potential for residential energy savings of about 20.9-24.9% in the city of Xiamen. Of the technical potential, about two-thirds to four-fifths are cost-effective from the government or society perspective. The cost-effectiveness is evaluated by comparing the "Levelized Cost of Conserved Energy (LCOCE)" of available advanced technical measures with the "Actual Cost" of conserved energy. The "Actual Cost" of energy is defined by adding the environmental externalities costs and hidden government subsidies over the retail prices of energy. The achievable potential analyses are particularly based on two key realistic factors: 1) the gradual ramping-up adoption process of advanced technical measures; and 2) individuals' adoption-decision making on them. For implementing the achievable

  9. An Audit of Repeat Testing at an Academic Medical Center: Consistency of Order Patterns With Recommendations and Potential Cost Savings.

    Science.gov (United States)

    Hueth, Kyle D; Jackson, Brian R; Schmidt, Robert L

    2018-05-31

    To evaluate the prevalence of potentially unnecessary repeat testing (PURT) and the associated economic burden for an inpatient population at a large academic medical facility. We evaluated all inpatient test orders during 2016 for PURT by comparing the intertest times to published recommendations. Potential cost savings were estimated using the Centers for Medicare & Medicaid Services maximum allowable reimbursement rate. We evaluated result positivity as a determinant of PURT through logistic regression. Of the evaluated 4,242 repeated target tests, 1,849 (44%) were identified as PURT, representing an estimated cost-savings opportunity of $37,376. Collectively, the association of result positivity and PURT was statistically significant (relative risk, 1.2; 95% confidence interval, 1.1-1.3; P < .001). PURT contributes to unnecessary health care costs. We found that a small percentage of providers account for the majority of PURT, and PURT is positively associated with result positivity.

  10. Energy savings in Danish residential building stock

    DEFF Research Database (Denmark)

    Tommerup, Henrik M.; Svendsen, Svend

    2006-01-01

    a short account of the technical energy-saving possibilities that are present in existing dwellings and presents a financial methodology used for assessing energy-saving measures. In order to estimate the total savings potential detailed calculations have been performed in a case with two typical...... buildings representing the residential building stock and based on these calculations an assessment of the energy-saving potential is performed. A profitable savings potential of energy used for space heating of about 80% is identified over 45 years (until 2050) within the residential building stock......A large potential for energy savings exists in the Danish residential building stock due to the fact that 75% of the buildings were constructed before 1979 when the first important demands for energy performance of building were introduced. It is also a fact that many buildings in Denmark face...

  11. A Method for Estimating Potential Energy and Cost Savings for Cooling Existing Data Centers

    Energy Technology Data Exchange (ETDEWEB)

    Van Geet, Otto

    2017-04-24

    NREL has developed a methodology to prioritize which data center cooling systems could be upgraded for better efficiency based on estimated cost savings and economics. The best efficiency results are in cool or dry climates where 'free' economizer or evaporative cooling can provide most of the data center cooling. Locations with a high cost of energy and facilities with high power usage effectiveness (PUE) are also good candidates for data center cooling system upgrades. In one case study of a major cable provider's data centers, most of the sites studied had opportunities for cost-effective cooling system upgrades with payback period of 5 years or less. If the cable provider invested in all opportunities for upgrades with payback periods of less than 15 years, it could save 27% on annual energy costs.

  12. Market analysis, energy savings potential, and future development requirements for Radiance. Final report

    Energy Technology Data Exchange (ETDEWEB)

    1993-10-01

    The Department of Energy (DOE) Office of Conservation and Renewable Energy (CE), Building Equipment Division has funded the development of a sophisticated computer rendering program called Radiance at Lawrence Berkeley Laboratories (LBL). The project review study included: (1) Surveys of the lighting profession to determine how designers would use an improved, user-friendly Radiance, (2) Elucidation of features, including how Radiance could be used to save energy, which could be incorporated into Radiance to facilitate its more widespread use, (3) Outline of a development plan and determination of what costs the DOE might incur if it were to proceed with the development of an improved version, and (4) Weighing the anticipated development costs against anticipated energy-saving benefits.

  13. Assessing Potential Energy Cost Savings from Increased Energy Code Compliance in Commercial Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Rosenberg, Michael I.; Hart, Philip R.; Athalye, Rahul A.; Zhang, Jian; Wang, Weimin

    2016-02-15

    The US Department of Energy’s most recent commercial energy code compliance evaluation efforts focused on determining a percent compliance rating for states to help them meet requirements under the American Recovery and Reinvestment Act (ARRA) of 2009. That approach included a checklist of code requirements, each of which was graded pass or fail. Percent compliance for any given building was simply the percent of individual requirements that passed. With its binary approach to compliance determination, the previous methodology failed to answer some important questions. In particular, how much energy cost could be saved by better compliance with the commercial energy code and what are the relative priorities of code requirements from an energy cost savings perspective? This paper explores an analytical approach and pilot study using a single building type and climate zone to answer those questions.

  14. An investigation on the fuel savings potential of hybrid hydraulic refuse collection vehicles

    Energy Technology Data Exchange (ETDEWEB)

    Bender, Frank A., E-mail: bender@isys.uni-stuttgart.de; Bosse, Thomas; Sawodny, Oliver

    2014-09-15

    Highlights: • Driving cycle acquisition in a refuse collection vehicle. • Vehicle modeling and validation for numerical simulations based on the measured driving cycle. • Fuel consumption analysis for a conventional diesel vehicle and a hybrid hydraulic vehicle. - Abstract: Refuse trucks play an important role in the waste collection process. Due to their typical driving cycle, these vehicles are characterized by large fuel consumption, which strongly affects the overall waste disposal costs. Hybrid hydraulic refuse vehicles offer an interesting alternative to conventional diesel trucks, because they are able to recuperate, store and reuse braking energy. However, the expected fuel savings can vary strongly depending on the driving cycle and the operational mode. Therefore, in order to assess the possible fuel savings, a typical driving cycle was measured in a conventional vehicle run by the waste authority of the City of Stuttgart, and a dynamical model of the considered vehicle was built up. Based on the measured driving cycle and the vehicle model including the hybrid powertrain components, simulations for both the conventional and the hybrid vehicle were performed. Fuel consumption results that indicate savings of about 20% are presented and analyzed in order to evaluate the benefit of hybrid hydraulic vehicles used for refuse collection.

  15. An investigation on the fuel savings potential of hybrid hydraulic refuse collection vehicles.

    Science.gov (United States)

    Bender, Frank A; Bosse, Thomas; Sawodny, Oliver

    2014-09-01

    Refuse trucks play an important role in the waste collection process. Due to their typical driving cycle, these vehicles are characterized by large fuel consumption, which strongly affects the overall waste disposal costs. Hybrid hydraulic refuse vehicles offer an interesting alternative to conventional diesel trucks, because they are able to recuperate, store and reuse braking energy. However, the expected fuel savings can vary strongly depending on the driving cycle and the operational mode. Therefore, in order to assess the possible fuel savings, a typical driving cycle was measured in a conventional vehicle run by the waste authority of the City of Stuttgart, and a dynamical model of the considered vehicle was built up. Based on the measured driving cycle and the vehicle model including the hybrid powertrain components, simulations for both the conventional and the hybrid vehicle were performed. Fuel consumption results that indicate savings of about 20% are presented and analyzed in order to evaluate the benefit of hybrid hydraulic vehicles used for refuse collection. Copyright © 2014 Elsevier Ltd. All rights reserved.

  16. An investigation on the fuel savings potential of hybrid hydraulic refuse collection vehicles

    International Nuclear Information System (INIS)

    Bender, Frank A.; Bosse, Thomas; Sawodny, Oliver

    2014-01-01

    Highlights: • Driving cycle acquisition in a refuse collection vehicle. • Vehicle modeling and validation for numerical simulations based on the measured driving cycle. • Fuel consumption analysis for a conventional diesel vehicle and a hybrid hydraulic vehicle. - Abstract: Refuse trucks play an important role in the waste collection process. Due to their typical driving cycle, these vehicles are characterized by large fuel consumption, which strongly affects the overall waste disposal costs. Hybrid hydraulic refuse vehicles offer an interesting alternative to conventional diesel trucks, because they are able to recuperate, store and reuse braking energy. However, the expected fuel savings can vary strongly depending on the driving cycle and the operational mode. Therefore, in order to assess the possible fuel savings, a typical driving cycle was measured in a conventional vehicle run by the waste authority of the City of Stuttgart, and a dynamical model of the considered vehicle was built up. Based on the measured driving cycle and the vehicle model including the hybrid powertrain components, simulations for both the conventional and the hybrid vehicle were performed. Fuel consumption results that indicate savings of about 20% are presented and analyzed in order to evaluate the benefit of hybrid hydraulic vehicles used for refuse collection

  17. Energy-saving and emission-abatement potential of Chinese coal-fired power enterprise: A non-parametric analysis

    International Nuclear Information System (INIS)

    Wei, Chu; Löschel, Andreas; Liu, Bing

    2015-01-01

    In the context of soaring demand for electricity, mitigating and controlling greenhouse gas emissions is a great challenge for China's power sector. Increasing attention has been placed on the evaluation of energy efficiency and CO 2 abatement potential in the power sector. However, studies at the micro-level are relatively rare due to serious data limitations. This study uses the 2004 and 2008 Census data of Zhejiang province to construct a non-parametric frontier in order to assess the abatement space of energy and associated CO 2 emission from China's coal-fired power enterprises. A Weighted Russell Directional Distance Function (WRDDF) is applied to construct an energy-saving potential index and a CO 2 emission-abatement potential index. Both indicators depict the inefficiency level in terms of energy utilization and CO 2 emissions of electric power plants. Our results show a substantial variation of energy-saving potential and CO 2 abatement potential among enterprises. We find that large power enterprises are less efficient in 2004, but become more efficient than smaller enterprises in 2008. State-owned enterprises (SOE) are not significantly different in 2008 from 2004, but perform better than their non-SOE counterparts in 2008. This change in performance for large enterprises and SOE might be driven by the “top-1000 Enterprise Energy Conservation Action” that was implemented in 2006. - Highlights: • Energy-saving potential and CO 2 abatement-potential for Chinese power enterprise are evaluated. • The potential to curb energy and emission shows great variation and dynamic changes. • Large enterprise is less efficient than small enterprise in 2004, but more efficient in 2008. • The state-owned enterprise performs better than non-state-owned enterprise in 2008

  18. Does Prevention Pay? Costs and Potential Cost-savings of School Interventions Targeting Children with Mental Health Problems.

    Science.gov (United States)

    Wellander, Lisa; Wells, Michael B; Feldman, Inna

    2016-06-01

    due to a reduction in the prevalence of mental health problems and averted additional support required. The school district was comprised of 6,256 students, with 310 students receiving additional support for their mental health problems. Of these, 143 received support in their original school due to either having ADHD (n = 111), psychosocial problems (n = 26), or anxiety/depression (n = 6). The payers' total cost of additional support was 2,637,850 Euro per school year (18,447 Euro per student). The cost of running both interventions for the school district was 953,643 Euro for one year, while the potential savings for these interventions were estimated to be 627,150 Euro. The estimated effects showed that there would be a reduction of students needing additional support (25 for ADHD, eight for psychosocial problems, and one for anxiety/depression), and the payer would receive a return on their invested resources in less than two years (1.5 years) after implementation. Preventive school interventions can both improve some children's mental health problems and be financially beneficial for the payer. However, they are still limited in their scope of reducing all students' mental health statuses to below clinical cut-offs; therefore, the preventive school interventions should be used as a supplement, but not a replacement, to current practices. The findings have political and societal implications, in that payers can reallocate their funds toward preventive measures targeting students' mental health problems, while reducing the costs. When evaluating public health actions, it is necessary to consider their economic impact. The resources are scarce and the decision makers need knowledge on how to allocate their resources in an efficient way. Cost-offset analysis is seen as one way for decision makers to comprehend research findings; however, such analyses tend to not include the full benefits of the interventions, and actual impacts need to be fully evaluated in routine

  19. Auxiliary energy in building technical services - Potential for savings and ways toward implementation; Hilfsenergie Haustechnik: Einspar-Potenziale und Umsetzungspfade

    Energy Technology Data Exchange (ETDEWEB)

    Nipkow, J. [Schweizerische Agentur fuer Energieeffizienz (SAFE), Zuerich (Switzerland); Peters, M.; Wapf, B. [Econcept AG, Zuerich (Switzerland)

    2006-11-15

    This report for the Swiss Federal Office of Energy (SFOE) examines the potential available for saving energy in the building technical services area. Savings of six to eight percent are noted for the area concerning pumps, fans, control systems, etc. The report presents the aims of the project and reviews the definition of auxiliary energy. National and international energy labels, limiting values and typical values for efficiency are examined. The results of surveys are presented and discussed as are the opinions and suggestions of planners, installers and architects. Manufacturers' opinions and marketing aspects are briefly examined, as are energy labels and regulations. Implementation of measures in various areas are described. Economical aspects and actions to be taken are discussed and educational measures are looked at. Follow-up projects are defined.

  20. Energy Savings Potential and Research, Development, & Demonstration Opportunities for Residential Building Heating, Ventilation, and Air Conditioning Systems

    Energy Technology Data Exchange (ETDEWEB)

    Goetzler, William [Navigant Consulting, Inc., Burlington, MA (United States); Zogg, Robert [Navigant Consulting, Inc., Burlington, MA (United States); Young, Jim [Navigant Consulting, Inc., Burlington, MA (United States); Schmidt, Justin [Navigant Consulting, Inc., Burlington, MA (United States)

    2012-10-01

    This report is an assessment of 135 different heating, ventilation, and air-conditioning (HVAC) technologies for U.S. residential buildings to identify and provide analysis on 19 priority technology options in various stages of development. The analyses include an estimation of technical energy-savings potential, descriptions of technical maturity, descriptions of non-energy benefits, descriptions of current barriers for market adoption, and descriptions of the technology's applicability to different building or HVAC equipment types. From these technology descriptions, are suggestions for potential research, development and demonstration (RD&D) initiatives that would support further development of the priority technology options.

  1. Energy saving and CO2-reduction potential of micro-cogeneration in the Netherlands (2010-2030). Update 2008

    International Nuclear Information System (INIS)

    Van Gastel, M.; De Jong, A.; Schlatmann, S.; Bakker, E.J.; Jeeninga, H.; Boerakker, Y.; Seebregts, A.; Menkveld, M.; Van Wolferen, H.; Turkstra, J.W.; Dam, J.; Harmsen, R.; Rooijers, F.; Koot, M.

    2008-05-01

    Various parties have been asked to come to a joint point of view with regard to establishing the potential of micro CHP for energy saving and CO2 emission reduction in the Netherlands from 2010 to 2030, assuming that micro CHP will have a successful market introduction. The result of this memo is a method for determining the technical potential of micro CHP for the reduction of energy use and CO2 emissions. This report is an update of the 2006 report [mk] [nl

  2. Energy Savings Potential and Research, Development, & Demonstration Opportunities for Commercial Building Heating, Ventilation, and Air Conditioning Systems

    Energy Technology Data Exchange (ETDEWEB)

    none,

    2011-09-01

    This report covers an assessment of 182 different heating, ventilation, and air-conditioning (HVAC) technologies for U.S. commercial buildings to identify and provide analysis on 17 priority technology options in various stages of development. The analyses include an estimation of technical energy-savings potential, description of technical maturity, description of non-energy benefits, description of current barriers for market adoption, and description of the technology’s applicability to different building or HVAC equipment types. From these technology descriptions, are suggestions for potential research, development and demonstration (RD&D) initiatives that would support further development of the priority technology options.

  3. Administrative waste in the U.S. health care system in 2003: the cost to the nation, the states, and the District of Columbia, with state-specific estimates of potential savings.

    Science.gov (United States)

    Himmelstein, David U; Woolhandler, Steffie; Wolfe, Sidney M

    2004-01-01

    This report provides nationwide and state-specific estimates of U.S. health care administration spending and potential savings in 2003 were the United States to institute a Canadian-style national health insurance system. The United States wastes more on health care bureaucracy than it would cost to provide health care to all its uninsured. Administrative expenses will consume at least dollar 399.4 billion of a total health expenditure of dollar 1,660.5 billion in 2003. Streamlining administrative overhead to Canadian levels would save approximately dollar 286.0 billion in 2003, dollar 6,940 for each of the 41.2 million Americans who were uninsured as of 2001. This is substantially more than would be needed to provide full insurance coverage. The cost of excess health bureaucracy in individual states is equally striking. For example, Massachusetts, with 560,000 uninsured state residents, could save about dollar 8,556 million in 2003 (dollar 16,453 per uninsured resident of that state) if it streamlined administration to Canadian levels. New Mexico, with 373,000 uninsured, could save dollar 1,500 million on health bureaucracy (dollar 4,022 per uninsured resident). Only a single-payer national health insurance system could garner these massive administrative savings, allowing universal coverage without any increase in total health spending. Because incremental reforms necessarily preserve the current fragmented and duplicative payment structure, they cannot achieve significant bureaucratic savings.

  4. Realizing potential savings of energy and emissions from efficient household appliances in India

    International Nuclear Information System (INIS)

    Parikh, Kirit S.; Parikh, Jyoti K.

    2016-01-01

    The paper projects households' stock of four major electricity consuming appliances till 2030 and explores policy options to accelerate adoption of more energy efficient appliances. India's rapid economic growth has enabled the growing middle class to buy household appliances in increasing numbers. The consequent rise in energy consumption and GHG emissions can be significantly reduced if consumers are motivated by awareness and options in the market to buy energy efficient appliances. India has introduced a star rating scheme for appliances, and even without incentives consumers purchase star-rated appliances. The stock of household appliances is projected using the data of a national sample survey of household consumption, observed sale of star-rated appliances and projected consumption distribution. Estimated savings in households' electricity consumption from just four appliances, ACs, refrigerators, TVs, and ceiling fans, for which data were available, range from 52 bKwh to 145 bkwh in 2030, reductions of 10–27%. The corresponding reduction in CO_2 emissions will be between 42 Mt and 116 Mt in 2030. With policies of finance and bulk procurement to reduce costs, emissions reduction can be 128 Mt in 2030, a reduction of 30%. - Highlights: • Estimates the stock of selected household appliances with 20 classes of rural and urban households in the years 2030 in India. • Assesses the economics of energy efficient appliances. • Estimates spread of selected energy efficient appliances. • Assesses savings in energy consumption and CO_2 emissions in four alternative scenarios. • Suggests policies to promote energy efficient appliances.

  5. Fossil energy savings and GHG mitigation potentials of ethanol as a gasoline substitute in Thailand

    International Nuclear Information System (INIS)

    Nguyen, Thu Lan T.; Gheewala, Shabbir H.; Garivait, Savitri

    2007-01-01

    One of the Thai government's measures to promote ethanol use is excise tax exemption, making gasohol cheaper than gasoline. The policy in favour of biofuels is being supported by their contribution to fossil energy savings and greenhouse gas (GHG) mitigation. An analysis of energy balance (EnB), GHG balance and GHG abatement cost has been done to evaluate molasses-based ethanol (MoE) in Thailand. A positive EnB of 19.2 MJ/L implies that MoE is a good substitute for gasoline, effective in fossil energy savings. GHG balance assessment based on the baseline scenario shows that emissions are most likely to increase with the substitution. Scenarios using biogas captured from spent wash treatment and rice husk to substitute coal used in ethanol conversion give encouraging results in improving the GHG balance. However, the higher price of MoE over gasoline currently has resulted in high GHG abatement costs, even under the best-case scenario. Compared to the many other climate strategies relevant to Thailand, MoE is much less cost effective. Governed by the rule of supply and demand, a strong fluctuation in molasses price is considered the main cause of volatile MoE price. Once supplies are stable, the trend of price drops would make MoE a reasonable option for national climate policy

  6. Lighting energy savings potential of split-pane electrochromic windows controlled for daylighting with visual comfort

    Energy Technology Data Exchange (ETDEWEB)

    Software, Anyhere; Fernandes, Luis; Lee, Eleanor; Ward, Greg

    2013-03-15

    A simulation study was conducted to evaluate lighting energy savings of split-pane electrochromic (EC) windows controlled to satisfy key visual comfort parameters. Using the Radiance lighting simulation software, interior illuminance and luminance levels were computed for a south-facing private office illuminated by a window split into two independently-controlled EC panes. The transmittance of these was optimized hourly for a workplane illuminance target while meeting visual comfort constraints, using a least-squares algorithm with linear inequality constraints. Blinds were successively deployed until visual comfort criteria were satisfied. The energy performance of electrochromics proved to be highly dependent on how blinds were controlled. With hourly blind position adjustments, electrochromics showed significantly higher (62percent and 53percent, respectively without and with overhang) lighting energy consumption than clear glass. With a control algorithm designed to better approximate realistic manual control by an occupant, electrochromics achieved significant savings (48percent and 37percent, respectively without and with overhang). In all cases, energy consumption decreased when the workplace illuminance target was increased. In addition, the fraction of time during which the occupant had an unobstructed view of the outside was significantly greater with electrochromics: 10 months out of the year versus a handful of days for the reference case.

  7. Structural Mass Saving Potential of a 5-MW Direct-Drive Generator Designed for Additive Manufacturing

    Energy Technology Data Exchange (ETDEWEB)

    Sethuraman, Latha [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Fingersh, Lee J [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Dykes, Katherine L [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Hayes, Austin [Rochester Institute of Technology

    2017-11-09

    As wind turbine blade diameters and tower height increase to capture more energy in the wind, higher structural loads results in more structural support material increasing the cost of scaling. Weight reductions in the generator transfer to overall cost savings of the system. Additive manufacturing facilitates a design-for-functionality approach, thereby removing traditional manufacturing constraints and labor costs. The most feasible additive manufacturing technology identified for large, direct-drive generators in this study is powder-binder jetting of a sand cast mold. A parametric finite element analysis optimization study is performed, optimizing for mass and deformation. Also, topology optimization is employed for each parameter-optimized design.The optimized U-beam spoked web design results in a 24 percent reduction in structural mass of the rotor and 60 percent reduction in radial deflection.

  8. Energy efficiency monitoring and economic analysis for energy saving potential in UNITEN

    International Nuclear Information System (INIS)

    Khan, M Reyasudin Basir; Jidin, Razali; Yew, Kang Chin; Shaaya, Sharifah Azwa; Pasupuleti, Jagadeesh

    2013-01-01

    This paper discusses on energy efficiency survey for typical buildings in Universiti Tenaga Nasional (UNITEN). Undeniably, wastage of energy will cause the increase of operation cost and depletion of fossil fuel resources which contributes to the climate change issue in the world. UNITEN was commenced in the late 1990s and most of the buildings in this university are not equipped with energy management system. Such system is the solution to reduce energy use while maximizing the comfort levels of the occupants. Disregard to the energy management system, the implementation of other energy saving measures is the main objective of this paper. By taking the right measures, the energy wastage in the buildings of this university can be reduced.

  9. Potentials for energy savings and long term energy demands for Croatian households sector

    DEFF Research Database (Denmark)

    Pukšec, Tomislav; Mathiesen, Brian Vad; Duic, Neven

    2011-01-01

    demand in the future, based on careful and rational energy planning. Different financial, legal and technological mechanisms can lead to significant savings in the households sector which also leads to lesser greenhouse gas emissions and lower Croatian dependence on foreign fossil fuels....... relevant. In order to plan future energy systems it is important to know future possibilities and needs regarding energy demand for different sectors. Through this paper long term energy demand projections for Croatian households sector will be shown with a special emphasis on different mechanisms, both...... financial, legal but also technological that will influence future energy demand scenarios. It is important to see how these mechanisms influence, positive or negative, on future energy demand and which mechanism would be most influential. Energy demand predictions in this paper are based upon bottom...

  10. Potentials for energy savings and long term energy demands for Croatian households sector

    DEFF Research Database (Denmark)

    Pukšec, Tomislav; Mathiesen, Brian Vad; Duic, Neven

    2013-01-01

    demand in the future, based on careful and rational energy planning. Different financial, legal and technological mechanisms can lead to significant savings in the households sector which also leads to lesser greenhouse gas emissions and lower Croatian dependence on foreign fossil fuels....... relevant. In order to plan future energy systems it is important to know future possibilities and needs regarding energy demand for different sectors. Through this paper long term energy demand projections for Croatian households sector will be shown with a special emphasis on different mechanisms, both...... financial, legal but also technological that will influence future energy demand scenarios. It is important to see how these mechanisms influence, positive or negative, on future energy demand and which mechanism would be most influential. Energy demand predictions in this paper are based upon bottom...

  11. Energy savings potential of a hybrid desiccant dehumidification air conditioning system in Beirut

    International Nuclear Information System (INIS)

    Ghali, Kamel

    2008-01-01

    In this work, the transient performance of a hybrid desiccant vapor compression air conditioning system is numerically simulated for the ambient conditions of Beirut. The main feature of this hybrid system is that the regenerative heat needed by the desiccant wheel is partly supplied by the condenser dissipated heat while the rest is supplied by an auxiliary gas heater. The hybrid air conditioning system of the present study replaces a 23 kW vapor compression unit for a typical office in Beirut characterized by a high latent load. The vapor compression subsystem size in the hybrid air conditioning system is reduced to 15 kW at the peak load when the regeneration temperature was fixed at 75 deg. C. Also the sensible heat ratio of the combined hybrid system increased from 0.47 to 0.73. Based on hour by hour simulation studies for a wide range of recorded ambient conditions of Beirut city, this paper predicts the annual energy consumption of the hybrid system in comparison with the conventional vapor compression system for the entire cooling season. The annual running costs savings for the hybrid system is 418.39 USD for a gas cost price of 0.141 USD/kg. The pay back period of the hybrid system is less than five years when the initial cost of the hybrid air conditioning system priced an additional 1712.00 USD. Hence, for a 20-year life cycle, the life cycle savings of the hybrid air conditioning system are 4295.19 USD

  12. Auxiliary aggregates: Effects on fuel consumption and potential fuel savings; Einfluss und Potenzial von Nebenaggregaten auf den Kraftstoffverbrauch

    Energy Technology Data Exchange (ETDEWEB)

    Rauchfuss, Lutz; Hindorf, Kay [Robert Bosch GmbH (Germany)

    2008-07-01

    New concepts and new developments in the field of auxiliary aggregates will help to reduce fuel consumption in the future. One aspect is the higher efficiency of components, the other on-demand power supply management. The contribution shows that thermomanagement, intelligent generator control, the start/stop system, auxiliary power control and fuel pumps may achieve considerable savings in the driving cycle and also in real operation. Efficient air conditioning systems and higher generator efficiency will show their potential in real operation. Cost-profit analyses are presented to prove the economic effects for the customer. (orig.)

  13. Milk production potential of two ryegrass cultivars with different total ...

    African Journals Online (AJOL)

    The aim of the study was to compare a new Italian ryegrass (Lolium multiflorum) cultivar (Enhancer), bred to contain a high total non-structural carbohydrate content, with the cultivar, Dargle, in terms of dry matter (DM) production, nutritional value, carrying capacity and milk production. The ryegrass cultivars were sown (25 ...

  14. Total bilirubin in nasogastric aspirates: A potential new indicator of ...

    African Journals Online (AJOL)

    Background: The aim of our study was to investigate if total bilirubin (T-bil), amylase (Amy), and sodium (Na) in nasogastric (NG) aspirates can refl ect gastrointestinal motility reliably. Materials and Methods: NG aspirates from all laparotomies lasting more than 150 min in children less than 12 months old were studied for 3 ...

  15. Energy Savings Potential of Flexible and Adaptive HVAC Distribution Systems for Office Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Loftness, Vivian; Brahme, Rohini; Mondazzi, Michelle; Vineyard, Edward; MacDonald, Michael

    2002-06-01

    It has been understood by architects and engineers that office buildings with easily re-configurable space and flexible mechanical and electrical systems are able to provide comfort that increases worker productivity while using less energy. Raised floors are an example of how fresh air, thermal conditioning, lighting needs, and network access can be delivered in a flexible manner that is not ''embedded'' within the structure. What are not yet documented is how well these systems perform and how much energy they can save. This area is being investigated in phased projects of the 21st Century Research Program of the Air-conditioning and Refrigeration Technology Institute. For the initial project, research teams at the Center for Building Performance and Diagnostics, Pittsburgh, Pennsylvania, and Oak Ridge National Laboratory, Oak Ridge, Tennessee, documented the diversity, performance, and incidence of flexible and adaptive HVAC systems. Information was gathered worldwide from journal and conference articles, case studies, manufactured products and assemblies, and interviews with design professionals. Their report thoroughly describes the variety of system types along with the various design alternatives observed for plenums, diffusers, individual control, and system integration. Many of the systems are illustrated in the report and the authors provide quantitative and qualitative comparisons. Among conclusions regarding key design issues, and barriers to widespread adoption, the authors state that flexible and adaptive HVAC systems, such as underfloor air, perform as well if not better than ceiling-based systems. Leading engineers have become active proponents after their first experience, which is resulting in these flexible and adaptive HVAC systems approaching 10 percent of the new construction market. To encourage adoption of this technology that improves thermal comfort and indoor air quality, follow-on work is required to further document

  16. Save Energy: Save Money!

    Science.gov (United States)

    Eccli, Eugene; And Others

    This publication is a collection of inexpensive energy saving tips and home improvements for home owners, particularly in low-income areas or in older homes. Section titles are: (1) Keeping Warm; (2) Getting Heat Where You Need It; (3) Using the Sun; (4) Furnaces, Stoves, and Fireplaces; (5) Insulation and Other Energy Needs; (6) Do-It-Yourself…

  17. Potential of energy saving with photovoltaic systems; Potencialidad de ahorro de energia con sistemas fotovoltaicos

    Energy Technology Data Exchange (ETDEWEB)

    Guzman S, Eusebio; Bratu S, Neagu [Universidad Autonoma Metropolitana, Mexico, D. F. (Mexico)

    1998-12-31

    This paper presents an approach on the application of photovoltaic systems in energy saving. The problem of the electric energy demand in the coming years is analyzed and its consequences on the environment and on the energy reserves of conventional sources. A model of the electric circuit equivalent to a photovoltaic cell illustrates the behavior of the photovoltaic cell in function of the climatological conditions. The former in order to show some of the limiting factors in this type of generator. Also, the evolution of the applications of the photovoltaic systems and its forecasting in the installed capacity in the next 20 years, is described. [Espanol] En este trabajo se presenta un enfoque de la aplicacion de los sistemas fotovoltaicos en el ahorro de energia. Se plantea el problema del crecimiento de la demanda energetica en los proximos anos y sus consecuencias sobre el medio ambiente y las reservas de energia por fuentes convencionales. Un modelo del circuito electrico equivalente de una celda fotovoltaica ilustra el comportamiento del generador fotovoltaico en funcion de las condiciones climatologicas. Lo anterior con el fin de mostrar algunas limitantes de este tipo de generador. Tambien se describe la evolucion de las aplicaciones de los sistemas fotovoltaicos y el pronostico de la potencia instalada en los proximos 20 anos.

  18. Smart Thermostats: An Experimental Facility to Test Their Capabilities and Savings Potential

    Directory of Open Access Journals (Sweden)

    Sergio Bustamante

    2017-08-01

    Full Text Available The European Commission has explained how heating and cooling in buildings and industry account for half of the energy consumption of the EU. Several studies explain how to achieve an energy saving at home, and the use of smart thermostats will help to reduce energy consumption while increasing the efficiency of households. In this article, a comparative evaluation was carried out between four smart thermostats that are now on the market, whose characteristics vary in terms of price, precision of measurements and set temperature, algorithms, etc. A thermal test chamber was designed and constructed from a refrigerator, a thermal blanket, a Raspberry Pi and the necessary electronic components for its control and data collection. From the tests carried out in the thermal chamber, data on the operation of the four thermostats such as the maintenance and the anticipation of the setpoint temperature, were obtained. It was necessary to run the system enough times for each thermostat to memorize the housing characteristics, such as its inertia and its thermal insulation. This would also allow for the generation of a better algorithm to regulate the temperature, which would create a lower oscillation with respect to the setpoint temperature. The learning of the thermostats was not demonstrated and for the anticipation mode it was seen that the thermostats failed to improve or learn in this aspect, as they did not improve the start-up times of the heating system, with the consequent increase in energy consumption.

  19. Analysis of potential energy, economic and environmental savings in residential buildings: Solar collectors combined with microturbines

    International Nuclear Information System (INIS)

    Suárez, I.; Prieto, M.M.; Fernández, F.J.

    2013-01-01

    Highlights: ► Centralization of energy systems for a group of buildings improves profitability. ► Thermal solar systems are economically interesting even in low radiation locations. ► Regulations currently in force determine the feasibility of high efficiency energy systems. - Abstract: This paper presents an analysis of a combined solar-cogeneration installation for providing energy services in a set of four residential buildings. Different configurations as regards the number of collectors and their orientation, the number of buildings grouped together, the type of microturbines used in the cogeneration system and their daily and annual operating period are studied from the legal, economic and environmental perspectives. The installation that fulfils the minimum requirements of the solar system coverage and the cogeneration system efficiency currently in force, and simultaneously leads to the highest energy, economic and environmental savings is the one that integrates both technologies and centralises the installation for the four buildings together. A payback period lower than 8 years is obtained that makes this investment recommendable, but it is also concluded that maintaining the existing subsidies for these technologies and lowering the costs of the equipment, are essential factors to ensure the feasibility of this type of installations

  20. Potential of energy saving with photovoltaic systems; Potencialidad de ahorro de energia con sistemas fotovoltaicos

    Energy Technology Data Exchange (ETDEWEB)

    Guzman S, Eusebio; Bratu S, Neagu [Universidad Autonoma Metropolitana, Mexico, D. F. (Mexico)

    1999-12-31

    This paper presents an approach on the application of photovoltaic systems in energy saving. The problem of the electric energy demand in the coming years is analyzed and its consequences on the environment and on the energy reserves of conventional sources. A model of the electric circuit equivalent to a photovoltaic cell illustrates the behavior of the photovoltaic cell in function of the climatological conditions. The former in order to show some of the limiting factors in this type of generator. Also, the evolution of the applications of the photovoltaic systems and its forecasting in the installed capacity in the next 20 years, is described. [Espanol] En este trabajo se presenta un enfoque de la aplicacion de los sistemas fotovoltaicos en el ahorro de energia. Se plantea el problema del crecimiento de la demanda energetica en los proximos anos y sus consecuencias sobre el medio ambiente y las reservas de energia por fuentes convencionales. Un modelo del circuito electrico equivalente de una celda fotovoltaica ilustra el comportamiento del generador fotovoltaico en funcion de las condiciones climatologicas. Lo anterior con el fin de mostrar algunas limitantes de este tipo de generador. Tambien se describe la evolucion de las aplicaciones de los sistemas fotovoltaicos y el pronostico de la potencia instalada en los proximos 20 anos.

  1. Estimating the potential of energy saving and carbon emission mitigation of cassava-based fuel ethanol using life cycle assessment coupled with a biogeochemical process model

    Science.gov (United States)

    Jiang, Dong; Hao, Mengmeng; Fu, Jingying; Tian, Guangjin; Ding, Fangyu

    2017-09-01

    Global warming and increasing concentration of atmospheric greenhouse gas (GHG) have prompted considerable interest in the potential role of energy plant biomass. Cassava-based fuel ethanol is one of the most important bioenergy and has attracted much attention in both developed and developing countries. However, the development of cassava-based fuel ethanol is still faced with many uncertainties, including raw material supply, net energy potential, and carbon emission mitigation potential. Thus, an accurate estimation of these issues is urgently needed. This study provides an approach to estimate energy saving and carbon emission mitigation potentials of cassava-based fuel ethanol through LCA (life cycle assessment) coupled with a biogeochemical process model—GEPIC (GIS-based environmental policy integrated climate) model. The results indicate that the total potential of cassava yield on marginal land in China is 52.51 million t; the energy ratio value varies from 0.07 to 1.44, and the net energy surplus of cassava-based fuel ethanol in China is 92,920.58 million MJ. The total carbon emission mitigation from cassava-based fuel ethanol in China is 4593.89 million kgC. Guangxi, Guangdong, and Fujian are identified as target regions for large-scale development of cassava-based fuel ethanol industry. These results can provide an operational approach and fundamental data for scientific research and energy planning.

  2. Evaluation of the cost saving potential of introducing Benepali® and Flixabi® on the European and Italian markets

    Directory of Open Access Journals (Sweden)

    Cristina Negrini

    2017-10-01

    CONCLUSIONS: The introduction of Benepali® and Flixabi® has a substantial cost saving potential for the Italian and European health systems, and the budget impact is sensitive to the uptake rates of the biosimilars market.

  3. Improved modelling of thermal energy savings potential in the existing residential stock using a newly available data source

    International Nuclear Information System (INIS)

    Dineen, D.; Rogan, F.; Ó Gallachóir, B.P.

    2015-01-01

    This paper presents a novel bottom up approach to modelling the energy savings potential of energy efficiency improvement measures to be applied through retrofit of the existing dwelling stock. It takes advantage of a newly available, rich dataset on the construction characteristics of the 2011 housing stock in Ireland. The methodological innovation centres on the use of wall construction type in the modelling and analysis. While Ireland is the focus, this approach is applicable to any EU member state for which data on dwelling characteristics exists from surveys carried as part of Energy Performance Certificate calculations. The model is calibrated to the national energy balance for 2011 by varying the internal temperature assumptions. Sensitivity analysis is performed on the effects of internal temperature and rebound. The paper also highlights some limitations posed by data availability on the accuracy and sophistication of models that can currently be developed, specifically in the Irish case. - Highlights: • Archetype model of energy savings potential from retrofit of existing dwelling stock. • Takes advantage of rich dataset on the construction characteristics of the Irish housing stock. • Innovative use of wall construction types in archetype definition possible due to improved data. • Results calibrated to top down estimate of heating demand by adjusting internal temperature. • Highlights limitations on the accuracy and sophistication of models posed by data availability.

  4. Potentials for energy savings and long term energy demand of Croatian households sector

    International Nuclear Information System (INIS)

    Pukšec, Tomislav; Vad Mathiesen, Brian; Duić, Neven

    2013-01-01

    Highlights: ► Long term energy demand of Croatian households sector has been modelled. ► Developed model can describe the whole households sector. ► Main modes include heating, cooling, electrical appliances, cooking and hot water. ► Different scenarios regarding future energy demand are presented and discussed. -- Abstract: Households represent one of the most interesting sectors, when analyzing Croatia’s energy balance. It makes up one of the largest energy consumers with around 75 PJ per year, which is almost 29% of Croatia’s final energy demand. Considering this consumption, implementing various mechanisms, which would lead to improvements in energy efficiency of this sector, seems relevant. In order to plan future energy systems, important would be to know future possibilities and needs regarding energy demand of different sectors. Through this paper, long term energy demand projections of Croatian households sector will be shown. Focus of the paper will be on various mechanisms influencing future energy demand scenarios. Important would be to quantify this influence, whether positive or negative, and see which mechanisms would be the most significant. Energy demand projections in this paper are based upon bottom-up approach model which combines and processes a large number of input data. The model will be compared to Croatian National Energy Strategy and certain differences and conclusions will be presented. One of the major conclusions shown in this paper is significant possibilities for energy efficiency improvements and lower energy demand in the future, based on careful and rational energy planning. Different financial, legal and technological mechanisms can lead to significant savings in the households sector which leads to lower GHG emissions and lower Croatian dependence on foreign fossil fuels.

  5. Energy saving potential of heat insulation solar glass: Key results from laboratory and in-situ testing

    International Nuclear Information System (INIS)

    Cuce, Erdem; Cuce, Pinar Mert; Young, Chin-Huai

    2016-01-01

    HISG (heat insulation solar glass) is a recently developed multi-functional glazing technology to mitigate energy consumption of buildings. HISG can generate electricity similar to conventional PV (photovoltaic) glazing products when exposed to sunlight, however it differs from them by having some extraordinary characteristic features such as thermal insulation, which is competitive with Argon filled triple glazed windows, acoustic comfort, remarkable energy saving potential and self-cleaning ability owing to TiO_2 nano coating. Within the scope of this research, latest results from laboratory and in-situ testing of HISG are presented in terms of its key role in mitigating heating and cooling demand of buildings as well as clean energy generation. Lighting and thermal comfort related parameters such as shading coefficient, UV, IR and visible light intensity are also investigated through the tests conducted in real operating conditions. It is achieved from the results that instant electricity generation of HISG is 16% higher than that of standard PV glazing owing to its nano layer reflective film. Shading coefficient of HISG is only 0.136, which provides almost 80% reduction in solar heat gain compared to ordinary glazing. Indoor air temperature measured from HISG test house in summer time is very close to the ambient temperature, whereas it is found to be 14.7 °C higher in ordinary glass test house due to greenhouse effect. Annual heating and cooling demand tests indicate that HISG provides 38 and 48% energy saving in heating and cooling season, respectively. - Highlights: • Nano layer reflective film of HISG enables 16% more power generation. • 80% of undesired outdoor thermal radiation is prevented by HISG. • HISG has a 100% UV blocking rate. • The shading coefficient of HISG is 0.136. • HISG provides 38 and 48% energy saving in heating and cooling season.

  6. Enhancing the potential of e-savings to boost women's investment ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    The project seeks to promote the transformative potential of financial ... best increase women's financial inclusion and labour market and economic choices ... Institution. Innovations for Poverty Action, a non-profit corporation. Institution Country.

  7. Project to demonstrate potential energy savings from industrial customers. Final report

    Energy Technology Data Exchange (ETDEWEB)

    None

    1978-06-01

    The full potential for electric load management was determined with respect to the industrial sector by adopting direct load management techniques. Certain options available to regulatory authorities and individual utilities to conserve energy are highlighted. By conducting a demonstration project on a representative sample of primary industrial customers, information could be obtained on the potential impact of direct load management methods and other end-use conservation programs on a system-wide basis or multi-system-wide basis. The study was conducted by the Michigan Public Service Commission in cooperation with the Detroit Edison Company.

  8. Potential fuel savings through electric camschaft adjustment; Moeglichkeiten zur Kraftstoffeinsparung durch elektrische Nockenwellenverstellung

    Energy Technology Data Exchange (ETDEWEB)

    Krebber-Hortmann, Karl; Koester, Andreas; Toennesmann, Andres; Brunetti, Costantino [Pierburg GmbH, Neuss (Germany). Abt. Vorentwicklung

    2013-11-01

    KSPG has developed an electric variable cam timing system. Using simulations and engine tests, KSPG demonstrates the potential reduction in fuel consumption that the system offers when combined with technologies such as fully variable valve gear in a gasoline engine. (orig.)

  9. Prediction of dynamic Rankine Cycle waste heat recovery performance and fuel saving potential in passenger car applications considering interactions with vehicles’ energy management

    International Nuclear Information System (INIS)

    Horst, Tilmann Abbe; Tegethoff, Wilhelm; Eilts, Peter; Koehler, Juergen

    2014-01-01

    Highlights: • Method for evaluating fuel saving potential of vehicle waste heat recovery systems. • Analysis of interactions between waste heat recovery system and vehicle. • Evaluation of fuel saving potential in dynamic motorway driving scenario. • Parameter study for increasing fuel saving potential of integrated system. - Abstract: Waste heat recovery (WHR) by means of a Rankine Cycle is a promising approach for achieving reductions in fuel consumption and, as a result, exhaust emissions of passenger car engines. To find the best compromise between complexity and fuel saving potential, methods for predicting the WHR performance for different system configurations and stationary as well as dynamic driving scenarios are needed. Since WHR systems are usually not included in today’s car concepts, they are mostly designed as add-on systems. As a result their integration may lead to negative interactions due to increased vehicle weight, engine backpressure and cooling demand. These effects have to be considered when evaluating the fuel saving potential. A new approach for predicting WHR performance and fuel saving potential was developed and is presented in this paper. It is based on simple dynamic models of a system for recovering exhaust gas waste heat and its interfaces with the vehicle: the exhaust system for heat input, the on-board electric system for power delivery and the engine cooling system for heat rejection. The models are validated with test bench measurements of the cycle components. A study of fuel saving potential in an exemplary dynamic motorway driving scenario shows the effect of vehicle integration: while the WHR system could improve fuel economy by 3.4%, restrictions in power output due to the architecture of the on-board electric system, package considerations, increased weight, cooling demand and exhaust gas backpressure lead to a reduction of fuel saving potential by 60% to 1.3%. A parameter study reveals that, in addition to weight

  10. Can we Save the rectum by watchful waiting or TransAnal microsurgery following (chemo) Radiotherapy versus Total mesorectal excision for early REctal Cancer (STAR-TREC study)?

    DEFF Research Database (Denmark)

    Rombouts, Anouk J M; Al-Najami, Issam; Abbott, Natalie L

    2017-01-01

    INTRODUCTION: Total mesorectal excision (TME) is the highly effective standard treatment for rectal cancer but is associated with significant morbidity and may be overtreatment for low-risk cancers. This study is designed to determine the feasibility of international recruitment in a study...... comparing organ-saving approaches versus standard TME surgery. METHODS AND ANALYSIS: STAR-TREC trial is a multicentre international randomised, three-arm parallel, phase II feasibility study in patients with biopsy-proven adenocarcinoma of the rectum. The trial is coordinated from Birmingham, UK...... endpoint of this phase II study is to demonstrate sufficient international recruitment in order to sustain a phase III study incorporating pelvic failure as the primary endpoint. Success in phase II is defined as randomisation of at least four cases per month internationally in year 1, rising to at least...

  11. Energy performance contracting - energy saving potential of selected energy conservation measures (ECM)

    Energy Technology Data Exchange (ETDEWEB)

    Johansson, M. (Dansk Energi Analyse A/S, Frederiksberg (Denmark)); Langkilde, G.; Olesen, Bjarne W. (Technical Univ. of Denmark, ICIEE, Kgs. Lyngby (Denmark)); Moerck, O. (Cenergia Energy Consultants, Herlev (Denmark)); Sundman, O. (DONG Energy, Copenhagen (Denmark)); Engelund Thomsen, K. (Aalborg Univ., SBi, Hoersholm (Denmark))

    2008-09-15

    This report has been developed under the research project 'Etablering af grundlag for energitjenester i Danmark' (project number: ENS-33031-0185) under the Danish research programme - EFP. The objective of this project has been to contribute to the utilisation of the large potential for energy conservations in the building sector within the public, industry and service sectors through the development of a better basis for decision making for both the Energy Service Companies (ESCOes) and the building owners. The EU directive on Energy Service Contracting points at the buildings as the area where the biggest potential market for energy services and energy efficiency improvements are. The EFP-project has two parts: (1) A Danish part and (2) participation in the international cooperation project 'Holistic Assesment Tool-Kit on Energy Efficient Retrofit Measures for Government Buildings (EnERGo)', Annex 46 under the IEA R and D program 'Energy Conservation In Buildings And Community Systems' (ECBCS). This report describes the Danish contributions to the IEA projects subtask B, which has a primary objective to develop a database of energy conservation measures (ECM) with descriptions and performance characteristics of these. (au)

  12. Energy performance contracting - energy saving potential of selected energy conservation measures (ECM)

    Energy Technology Data Exchange (ETDEWEB)

    Johansson, M [Dansk Energi Analyse A/S, Frederiksberg (Denmark); Langkilde, G; Olesen, Bjarne W [Technical Univ. of Denmark, ICIEE, Kgs. Lyngby (Denmark); Moerck, O [Cenergia Energy Consultants, Herlev (Denmark); Sundman, O [DONG Energy, Copenhagen (Denmark); Engelund Thomsen, K [Aalborg Univ., SBi, Hoersholm (Denmark)

    2008-09-15

    This report has been developed under the research project 'Etablering af grundlag for energitjenester i Danmark' (project number: ENS-33031-0185) under the Danish research programme - EFP. The objective of this project has been to contribute to the utilisation of the large potential for energy conservations in the building sector within the public, industry and service sectors through the development of a better basis for decision making for both the Energy Service Companies (ESCOes) and the building owners. The EU directive on Energy Service Contracting points at the buildings as the area where the biggest potential market for energy services and energy efficiency improvements are. The EFP-project has two parts: (1) A Danish part and (2) participation in the international cooperation project 'Holistic Assesment Tool-Kit on Energy Efficient Retrofit Measures for Government Buildings (EnERGo)', Annex 46 under the IEA R and D program 'Energy Conservation In Buildings And Community Systems' (ECBCS). This report describes the Danish contributions to the IEA projects subtask B, which has a primary objective to develop a database of energy conservation measures (ECM) with descriptions and performance characteristics of these. (au)

  13. Power consumption of lifts and potential for energy savings; Elektrizitaetsverbrauch und Einspar-Potenziale bei Aufzuegen

    Energy Technology Data Exchange (ETDEWEB)

    Nipkow, J.

    2005-07-01

    This final report for the Swiss Federal Office of Energy (SFOE) reviews the results of a study made on the electricity consumption of lifts, which estimates that around 0.5% of Swiss power consumption is caused by lift installations. The results of measurements made on 33 various lift installations and their power consumption are presented. The SIA 380/4 model used to determine energy consumption on the basis of the number of movements is described. Stand-by and lighting consumption is examined, which, according to the authors' conclusions, offer considerable room for improvement, especially for lifts in residential buildings. A further significant potential for improvement is also noted which can be achieved when renewing older systems. The avoidance of inefficient concepts by the use of guidelines for architects, planners and customers is recommended.

  14. Energy conservation: policy issues and end-use scenarios of savings potential

    Energy Technology Data Exchange (ETDEWEB)

    1978-09-01

    The enclosed work is based on previous research during this fiscal year, contained in Construction of Energy Conservation Scenarios: Interim Report of Work in Progress, June 1978. Five subjects were investigated and summaries were published for each subject in separate publications. This publication summarizes policy issues on the five subjects: tradeoffs of municipal solid-waste-processing alternatives (economics of garbage collection; mechanical versus home separation of recyclables); policy barriers and investment decisions in industry (methodology for identification of potential barriers to industrial energy conservation; process of industrial investment decision making); energy-efficient recreational travel (information system to promote energy-efficient recreational travel; recreational travel; national importance and individual decision making); energy-efficient buildings (causes of litigation against energy-conservation building codes; description of the building process); and end-use energy-conservation data base and scenaerios (residential; commercial; transportation; and industrial).

  15. The Cost of Medicaid Savings: The Potential Detrimental Public Health Impact of Neonatal Circumcision Defunding

    Directory of Open Access Journals (Sweden)

    Annie L. Andrews

    2012-01-01

    Full Text Available Objective. To project the increased incidence of HIV and subsequent costs resulting from the expected decreased rate of circumcision due to Medicaid defunding in one southeastern state. Methods. Using 2009 South Carolina (SC Medicaid birth cohort (n=29,316, we calculated expected heterosexually acquired HIV cases at current circumcision rates. To calculate age/race/gender specific HIV incidence rates, we used 2009 South Carolina Department of Health and Environmental Control reported gender and race specific HIV cases, CDC reported age distribution of HIV cases, and 2009 S.C. population data. Accounting for current circumcision rates, we calculated the change in incidence of heterosexually acquired HIV assuming circumcision provides 60% protection against HIV transmission to males and 46% protection against male to female transmission. Published lifetime cost of HIV was used to calculate the cost of additional HIV cases. Results. Assuming Medicaid circumcision rates decrease from current nationally reported levels to zero secondary to defunding, we project an additional 55 male cases of HIV and 47 female cases of HIV among this birth cohort. The total cost discounted to time of infection of these additional HIV cases is $20,924,400 for male cases and $17,711,400 for female cases. The cost to circumcise males in this birth cohort at currently reported rates is $4,856,000. Conclusions. For every year of decreased circumcision rates due to Medicaid defunding, we project over 100 additional HIV cases and $30,000,000 in net medical costs.

  16. Request of laboratory liver tests in primary care in Spain: potential savings if appropriateness indicator targets were achieved.

    Science.gov (United States)

    Salinas, Maria; López-Garrigós, Maite; Flores, Emilio; Uris, Joaquín; Leiva-Salinas, Carlos

    2015-10-01

    Liver laboratory tests are used to screen for liver disease, suggest the underlying cause, estimate the severity, assess prognosis, and monitor the efficacy of therapy. The aim of this study was to compare the liver laboratory tests requesting patterns by GPs in Spain, according to geographic and hospital characteristics, to investigate the degree of requesting appropriateness. One hundred and forty-one clinical laboratories were invited to participate from diverse regions across Spain. They filed out the number of laboratory liver tests requested by GPs for the year 2012. Two types of appropriateness indicators were calculated: every test request per 1000 inhabitants or ratios of related tests requests. The indicator results obtained were compared between the different hospitals, according to their setting, location, and management. The savings generated, if each area would have achieved indicator targets, were calculated. We recruited 76 laboratories covering a population of 17,679,195 inhabitants. GPs requested 20,916,780 laboratory liver tests in the year 2012. No differences were obtained according to their setting. Lactate dehydrogenase and direct bilirubin per 1000 inhabitants were significantly higher in institutions with private management. Largest differences were observed between communities. Nine, 31, 0, and 13 laboratories, respectively, achieved the aspartate aminotransferase, lactate dehydrogenase, γ-glutamyl transpeptidase, and total bilirubin-related alanine aminotransferase indicator targets. Reaching ratios would have resulted in savings of €1,028,468. There was a high variability in the request of liver tests. This emphasizes the need to implement interventions to improve appropriate use of liver tests.

  17. Margins in breast conserving surgery: The financial cost & potential savings associated with the new margin guidelines.

    Science.gov (United States)

    Singer, Lauren; Brown, Eric; Lanni, Thomas

    2016-08-01

    In this study, we compare the indications for re-excision, the findings of additional tumor in the re-excision specimen as they relate to margin status, and costs associated with re-excision based on recent new consensus statements. A retrospective analysis was performed on 462 patients with invasive breast carcinoma who underwent at least one lumpectomy between January 2011 and December 2013. Postoperative data was analyzed based on where additional disease was found, as it relates to the margin status of the initial lumpectomy and the additional direct costs associated with additional procedures. Of the 462 patients sampled, 149 underwent a re-excision surgery (32.2%). Four patients underwent mastectomy as their second operation. In the 40 patients with additional disease found on re-excision, 36 (90.0%) of them had a positive margin on their initial lumpectomy. None of the four mastectomy patients had residual disease. The mean cost of the initial lumpectomy for all 462 patients was $2118.01 plus an additional $1801.92 for those who underwent re-excision. A positive margin was most predictive of finding residual tumor on re-excision as would be expected. Using old criteria only 0.07% (4/61) of patients who had undergone re-excision with a 'clear' margin, had additional tumor found, at a total cost of $106,354.11. Thus, the new consensus guidelines will lead to less overall cost, at no clinical risk to patients while reducing a patient's surgical risk and essentially eliminating delays in adjuvant care. Copyright © 2016 Elsevier Ltd. All rights reserved.

  18. Potential Cost Savings for Use of 3D Printing Combined With 3D Imaging and CPLM for Fleet Maintenance and Revitalization

    Science.gov (United States)

    2014-04-30

    bäÉîÉåíÜ=^ååì~ä=^Åèìáëáíáçå= oÉëÉ~êÅÜ=póãéçëáìã= qÜìêëÇ~ó=pÉëëáçåë= sçäìãÉ=ff= = Potential Cost Savings for Use of 3D Printing Combined With 3D...TYPE 3. DATES COVERED 00-00-2014 to 00-00-2014 4. TITLE AND SUBTITLE Potential Cost Savings for Use of 3D Printing Combined With 3D Imaging and...Chair: RADM David Lewis, USN Program Executive Officer, SHIPS Potential Cost Savings for Use of 3D Printing Combined With 3D Imaging and CPLM for

  19. Assessment of potential energy savings following the replacement of gear-motor-driven systems by frequency-converter-fed direct drives; Energiesparpotential bei Ersatz von Getriebemotoren durch FU-Antriebe. Potentialanalyse

    Energy Technology Data Exchange (ETDEWEB)

    Tanner, R.; Riesen, H. J.

    2007-03-15

    This project deals with the energy saving potential that can be achieved by replacing gear motor driven systems by frequency converter fed direct drives. Estimates have shown that due to the high percentage of gear motor installations, which amounts to approximately 10% of all motor driven systems, a significant amount of energy could be saved. However, several barriers impose major restrictions to the broad application of such actions: With the exception of worm gears that reach about 20% of all gear drives, todays' gears already offer a high efficiency of 97-98%. Gear motors are often included in OEM integrated solutions. Many processes require complex adaptations that can complicate replacements or make it even impractical. For low speed or high torque requirements, gear motors may have a dominant advantage concerning the compactness. Our investigations have shown, that in spite of such barriers the replacement of gear motors by direct motors can sum up to a significant amount of energy savings in many cases. Looking at the worm gear systems and the restricted speed and torque ranges that are covered by the direct drives from several suppliers we assume a total saving potential of about 78 GWh per year for Switzerland. (author)

  20. Energy savings in CSFR - building sector

    International Nuclear Information System (INIS)

    Jacobsen, F.R.

    1993-01-01

    The Czechoslovak/Danish project on energy savings in buildings proves that it is possible to save up to 30% of the energy in buildings. 10% can be saved at an investment of 27 bill KCS. The total investment that is needed to save 30% is 140 bill KCS. Further energy savings can be obtained through more energy efficient supply systems. Information dissemination is important for the energy saving programme as are economic incentives. Investments in energy savings should be profitable for the investor, but this is not the case in the Czech and Slovak republics today. Changes are needed. Energy prices are still to low, compared to investment costs. Financial possibilities are not satisfactory for private investors. Price systems are not favourable to investment in energy savings. Training is needed for boiler men and energy consultants. Legislation is essential for the support of the full range of activities in the energy sector. Research and Development activities must back up the development of the sector. Pilot projects can illuminate the savings potential. The production of technical equipment for control and metering and production of insulation materials must be promoted. (AB)

  1. The Energy Saving Potential of Occupancy-Based Lighting Control Strategies in Open-Plan Offices: The Influence of Occupancy Patterns

    Directory of Open Access Journals (Sweden)

    Christel de Bakker

    2017-12-01

    Full Text Available Occupancy-based lighting control strategies have been proven to be effective in diminishing offices’ energy consumption. These strategies have typically worked by controlling lighting at the room level but, recently, lighting systems have begun to be equipped with sensors on a more fine-grained level, enabling lighting control at the desk level. For some office cases, however, the savings gained using this strategy may not outweigh the costs and design efforts compared to room control. This is because, in some offices, individual occupancy patterns are similar, hence the difference in savings between desk and room control would be minimal. This study examined the influence of occupancy pattern variance within an office space on the relative energy savings of control strategies with different control zone sizes. We applied stochastic modeling to estimate the occupancy patterns, as this method can account for uncertainty. To validate our model, simulation results were compared to earlier studies and real measurements, which demonstrated that our simulations provided realistic occupancy patterns. Next, office cases varying in both job-function type distribution and office policy were investigated on energy savings potential to determine the influence of occupancy pattern variance. The relative energy savings potential of the different control strategies differed minimally for the test cases, suggesting that variations in individual occupancy patterns negligibly influence energy savings. In all cases, lighting control at the desk level showed a significantly higher energy savings potential than strategies with lower control zone granularity, suggesting that it is useful to implement occupancy-based lighting at the desk level in all office cases. This strategy should, thus, receive more attention from both researchers and lighting designers.

  2. How much electricity can we save by using direct current circuits in homes? Understanding the potential for electricity savings and assessing feasibility of a transition towards DC powered buildings

    International Nuclear Information System (INIS)

    Glasgo, Brock; Azevedo, Inês Lima; Hendrickson, Chris

    2016-01-01

    Highlights: • DC distribution systems are analyzed using monitored appliance and solar PV data. • DC-distributed PV energy generates savings under real-world load and solar profiles. • Savings from direct-DC are generally not cost-effective in current markets. • Non-technical hurdles remain before DC can be widely adopted in US homes. - Abstract: Advances in semiconductor-based power electronics and growing direct current loads in buildings have led researchers to reconsider whether buildings should be wired with DC circuits to reduce power conversions and facilitate a transition to efficient DC appliances. The feasibility, energy savings, and economics of such systems have been assessed and proven in data centers and commercial buildings, but the outcomes are still uncertain for the residential sector. In this work, we assess the technical and economic feasibility of DC circuits using data for 120 traditionally-wired AC homes in Austin, Texas to understand the effect of highly variable demand profiles on DC-powered residences, using appliance-level use and solar generation data, and performing a Monte Carlo simulation to quantify costs and benefits. Results show site energy savings between 9% and 20% when solar PV is distributed to all home appliances. When battery storage for excess solar energy is considered, these savings increase to 14–25%. At present DC equipment prices, converting all equipment to DC causes levelized annual costs of electricity to homeowners to roughly double. However, by converting only homes’ air conditioning condensing units to DC, the costs of direct-DC are greatly reduced and home site energy savings of 7–16% are generated. In addition to quantifying savings, we find major nontechnical barriers to implementing direct-DC in homes. These include a lack of standards for such systems, a relatively small market for DC appliances and components, utility programs designed for AC power, and a workforce unfamiliar with DC

  3. Household Savings

    DEFF Research Database (Denmark)

    Browning, Martin; Lusardi, Annamaria

    suggested in the informal saving literature can be captured in the standard optimizing model. Particular attention is given to recent work on the precautionary motive and its implications for saving and consumption behavior. We also discuss the "behavioral" or "psychological" approach that eschews the use......In this survey, we review the recent theoretical and empirical literature on household saving and consumption. The discussion is structured around a list of motives for saving and how well the standard theory captures these motives. We show that almost all of the motives for saving that have been...

  4. Energy consumption and energy-saving potential analysis of pollutant abatement systems in a 1000MW coal-fired power plant.

    Science.gov (United States)

    Yang, Hang; Zhang, Yongxin; Zheng, Chenghang; Wu, Xuecheng; Chen, Linghong; Gao, Xiang; Fu, Joshua S

    2018-05-10

    The pollutant abatement systems are widely applied in the coal-fired power sector and the energy consumption was considered an important part of the auxiliary power. An energy consumption analysis and assessment model of pollutant abatement systems in a power unit was developed based on the dynamic parameters and technology. The energy consumption of pollutant abatement systems in a 1000 MW coal-fired power unit which meet the ultra-low emission limits and the factors of operating parameters including unit load and inlet concentration of pollutants on the operating power were analyzed. The results show that the total power consumption of the pollutant abatement systems accounted for 1.27% of the gross power generation during the monitoring period. The WFGD system consumed 67% of the rate while the SCR and ESP systems consumed 8.9% and 24.1%. The power consumption rate of pollutant abatement systems decreased with the increase of unit load and increased with the increase of the inlet concentration of pollutants. The operation adjustment was also an effective method to increase the energy efficiency. For example, the operation adjustment of slurry circulation pumps could promote the energy-saving operation of WFGD system. Implication Statement The application of pollutant abatement technologies increases the internal energy consumption of the power plant, which will lead to an increase of power generation costs. The real-time energy consumption of the different pollutant abatement systems in a typical power unit is analyzed based on the dynamic operating data. Further, the influence of different operating parameters on the operating power of the system and the possible energy-saving potential are analyzed.

  5. Potential of bioclimatic architecture for energy saving in buildings; Potencial de la arquitectura bioclimatica para ahorro de energia en edificios

    Energy Technology Data Exchange (ETDEWEB)

    Garcia Chavez, Jose Roberto [Universidad Autonoma Metropolitana-Azcapotzalco, Mexico, D. F. (Mexico)

    1994-12-31

    The design and construction of current buildings has been characterized, most of all, in the last 30 years, for the lack of consideration in the design process of aspects that nowadays represent a fundamental importance. These aspects are related to energy conservation and environmental protection, with man as the main center of attention for the optimum satisfaction of its physiological as well as psychological needs. In this paper are presented the causes for the lack of consideration of the mentioned aspects and guidelines to follow are set forth for their integration in the design process. Also the architecture potential with a bioclimatic approach is analyzed, for energy saving in buildings. [Espanol] El diseno y construccion de edificios contemporaneos se ha caracterizado, sobre todo en los ultimos treinta anos, por la falta de consideracion en el proceso de diseno, de aspectos que hoy en dia revisten una importancia primordial. Estos aspectos se relacionan con la preservacion de la energia y del medio ambiente, teniendo al hombre como principal centro de atencion, para la satisfaccion optima de sus necesidades, tanto fisiologicas como psicologicas. En este trabajo, se presentan las causas de la falta de consideracion de los aspectos antes citados y se plantean las pautas a seguir para su integracion en el proceso de diseno. Asi mismo, se analiza el potencial de la arquitectura con un enfoque bioclimatico, para ahorro de energia en los edificios.

  6. A Study of Application Layer Paradigm for Lower Layer Energy Saving Potentials in Cloud-Edge Social User Wireless Image Sharing

    Directory of Open Access Journals (Sweden)

    Wei Wang

    2015-08-01

    Full Text Available Energy saving becomes critical in modern cloud wireless multimedia and mobile communication systems. In this paper we propose to study a new paradigm named application layer Position-Value diversity for wireless image sharing for cloud-edge communications, which has significant energy saving potentials for modern wireless networking systems. In this new paradigm, saving energy is achieved by looking into application layer imaging traffic, in stead of MAC-PHY protocols at lower layers, and partitioning it into important positions and unimportant values. This paradigm could be integrated to existing wavelet-based tree compression, and truncation of image bit streams could be performed with regards to wireless communication energy budget estimation. Simulation results demonstrated that there are significant potentials of communication energy efficiency gain and Quality of Experience (QoE enhancement in wireless image communication systems.

  7. Investigation on the Energy Saving Potential of Using a Novel Dew Point Cooling System in Data Centres

    Directory of Open Access Journals (Sweden)

    Yin Bi

    2017-10-01

    Full Text Available Abstract: Information technology (IT has brought significant changes in people’s lives. As an important part of the IT industry, data centres (DCs have been rapidly growing in both the number and size over the past 40 years. Around 30% to 40% of electricity consumption in DCs is used for space cooling, thus leading to very inefficient DC operation. To identify ways to reduce the energy consumption for space cooling and increase the energy efficiency of DCs’ operation, a dedicated investigation into the energy usage in DCs has been undertaken and a novel high performance dew point cooling system was introduced into a DC operational scheme. Based on the cooling load in DCs, a case study was carried out to evaluate the energy consumptions and energy usage effectiveness when using the novel dew point cooling system in different scales of DCs in various climates. It was found that by using the novel dew point cooling system, for 10 typical climates a DC can have a much lower power usage effectiveness (PUE of 1.10 to 1.22 compared to that of 1.7 to 3.7 by using existing traditional cooling systems, leading to significantly increased energy efficiency of the DC operation. In addition, the energy performance by managing the cooling air supply at the different levels in DCs, i.e., room, row and rack level, was simulated by using a dynamic computer model. It was found that cooling air supply at rack level can provide a higher energy efficiency in DCs. Based on the above work, the energy saving potential in DCs was conducted by comparing DCs using an the novel dew point cooling system and the optimum management scheme for the cooling air supply to that using traditional air cooling systems and the same supply air management. Annual electricity consumptions for the two cases were given. It was found that by using the novel dew point cooling system and optimum management system for the cooling air supply, an 87.7~91.6% electricity consumption saving for

  8. Electric energy savings from new technologies

    Energy Technology Data Exchange (ETDEWEB)

    Moe, R.J.; Harrer, B.J.; Kellogg, M.A.; Lyke, A.J.; Imhoff, K.L.; Fisher, Z.J.

    1986-01-01

    Purpose of the report is to provide information about the electricity-saving potential of new technologies to OCEP that it can use in developing alternative long-term projections of US electricity consumption. Low-, base-, and high-case scenarios of the electricity savings for ten technologies were prepared. The total projected annual savings for the year 2000 for all ten technologies were 137 billion kilowatt hours (BkWh), 279 BkWh, and 470 BkWh, respectively, for the three cases. The magnitude of these savings projections can be gauged by comparing them to the Department's reference case projection for the 1985 National Energy Policy Plan. In the Department's reference case, total consumption in 2000 is projected to be 3319 BkWh. Thus, the savings projected here represent between 4% and 14% of total consumption projected for 2000. Because approximately 75% of the base-case estimate of savings are already incorporated into the reference forecast, reducing projected electricity consumption from what it otherwise would have been, the savings estimated here should not be directly subtracted from the reference forecast.

  9. FY 1999 report on energy conservation potential survey of measurement and control systems and energy-saving equipment

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-03-01

    Studies are conducted with a view to connecting a survey in Egypt to CDM (clean development mechanism) adopted at COP3 (Third Session of the Conference of the Parties to the United Nations Framework Convention on Climate Change). The survey covers the textile industry which is one of Egypt's main industries, and investigation is conducted for extending technical recommendation to 11 textile mills (including dyeing plants) about how to reduce greenhouse gas (CO2) emissions through energy conservation efforts. Required investment, investment recovery period, and reduction in CO2 emissions are calculated. About CO2 reduction, it is found that there will be a CO2 reduction of 44,702 tons/year at a rate of 22.4%, investment of 838.56-million yen, CO2 reduction of 53.3 tons/million yen, and investment of 18,750-yen/t-CO2. As for energy conservation, there will be a reduction at a rate of 14,449 toe/year in energy consumption, investment of 838.56-million yen, energy saved at a rate of 17.2 toe/million yen, and investment of 5,800 yen/toe. There will be an annual reduction in utility cost of 125.79-million yen at a cost reduction rate of 10.3%. The investment recovery period is calculated to be 5.8 years. The Egyptian textile has high potentials for CO2 reduction, and will present an excellent opportunity for a CDM project. (NEDO)

  10. Potential for Water Savings by Defoliation of Saltcedar (Tamarix spp.) by Saltcedar Beetles (Diorhabda carinulata) in the Upper Colorado River Basin

    Science.gov (United States)

    Nagler, P. L.; Nguyen, U.; Bateman, H. L.; Jarchow, C.; van Riper, C., III; Waugh, W.; Glenn, E.

    2016-12-01

    Northern saltcedar beetles (Diorhabda carinata) have spread widely in riparian zones on the Colorado Plateau since their initial release in 2002. One goal of the releases was to reduce water consumption by saltcedar in order to conserve water through reduction of evapotranspiration (ET). The beetle moved south on the Virgin River and reached Big Bend State Park in Nevada in 2014, an expansion rate of 60 km/year. This is important because the beetle's photoperiod requirement for diapause was expected to prevent them from moving south of 37°N latitude, where endangered southwest willow flycatcher habitat occurs. In addition to focusing on the rate of dispersal of the beetles, we used remote sensing estimates of ET at 13 sites on the Colorado, San Juan, Virgin and Dolores rivers and their tributaries to estimate riparian zone ET before and after beetle releases. We estimate that water savings from 2007-2015 was 31.5 million m3/yr (25,547 acre-ft/yr), amounting to 0.258 % of annual river flow from the Upper Colorado River Basin to the Lower Basin. Reasons for the relatively low potential water savings are: 1) baseline ET before beetle release was modest (0.472 m/yr); 2) reduction in ET was low (0.061 m/yr) because saltcedar stands tended to recover after defoliation; 3) riparian ET even in the absence of beetles was only 1.8 % of river flows, calculated as the before beetle average annual ET (472 mm/yr) times the total area of saltcedar (51,588 ha) divided by the combined total average annual flows (1964-2015) from the upper to lower catchment areas of the Colorado River Basin at the USGS gages (12,215 million m3/yr or 9.90 million acre-ft). Further research is suggested to concentrate on the ecological impacts (both positive and negative) of beetles on riparian zones and on identifying management options to maximize riparian health.

  11. Kennecott Utah Copper Corporation: Facility Utilizes Energy Assessments to Identify $930,000 in Potential Annual Savings

    Energy Technology Data Exchange (ETDEWEB)

    2004-07-01

    Kennecott Utah Copper Corporation (KUCC) used targeted energy assessments in the smelter and refinery at its Bingham Canyon Mine, near Salt Lake City, Utah. The assessment focused mainly on the energy-intensive processes of copper smelting and refining. By implementing the projects identified, KUCC could realize annual cost savings of $930,000 and annual energy savings of 452,000 MMBtu. The projects would also reduce maintenance, repair costs, waste, and environmental emissions. One project would use methane gas from an adjacent municipal dump to replace natural gas currently used to heat the refinery electrolyte.

  12. The technical-economic potential of thermal energy saving in hospitals; El potencial tecnico-economico de ahorro de energia termica en hospitales

    Energy Technology Data Exchange (ETDEWEB)

    Herrera, A. [Universidad Nacional Autonoma de Mexico (Mexico); Islas, J [Universidad Nacional Autonoma de Mexico, Mexico, D.F. (Mexico); Arriola, A. [Instituto de Investigaciones Electricas, Cuernavaca, Morelos (Mexico)

    2001-07-01

    The hospitals are important consumers of energy. At the General Hospital of Zone (HGZ) N of the IMSS in Aguscalientes (HGZ N . IMSS Ags.), the diesel oil is the main fuel that is used to satisfy the requirements of thermal energy of the hospital. According to the data collected by this author, this fuel represented in 2001, 75% of its total energy consumption and the 67.9% of its total costs in energy that ascended to $396.131 (December 2001 Dollars) Since this last amount represents an important percentage of the total expenses of the hospital (29.367 million dollars) it is important to determine the technical-economic possibilities of thermal energy saving of the hospital. The HGZ N 1 IMSS Ags. is located in a ampler conglomerate where the IMSS units are located, such as, the regional laundry, the sport unit, the center of social security, the familiar medicine unit N 1 and the hospital. Nevertheless departing from the installation of the electrical systems and the provision of steam and hot water to the hospital, the electrical and thermal fluids of all this facilities are distributed. Due to this situation, in this work we will refer to the global consumption of the IMSS of Aguascalientes development where the hospital is the main consumer of thermal energy. In the present work we will calculate the technical-economic potential of thermal energy saving in the development of the IMSS through the thermodynamic technique of folding point or pinch technique. [Spanish] Los hospitales son importantes consumidores de energia. En el Hospital General de Zona N del IMSS en Aguscalientes (HGZ N - IMSS Ags.), el diesel es el principal combustible que se usa para satisfacer los requerimientos de energia termica del hospital. Segun los datos obtenidos por el autor anterior, este combustible represento en 2001 el 75% de su consumo total energetico y el 67.9% de sus costos totales en energeticos que ascendieron a $396,131 (dolares de diciembre de 2001). Dado que esta ultima

  13. Preliminary study of potential energy savings within business and industry by reducing over-harmonies; Forundersoegelse af muligheder for energibesparelser i erhvervslivet ved reduktion af overharmoniske stroemme

    Energy Technology Data Exchange (ETDEWEB)

    Johansson, M. (Dansk Energi Analyse A/S, Frederiksberg (Denmark)); Kehr, J.M. (ABB A/S, Skovlunde (Denmark)); Hoejte Hansen, H. (Balslev A/S (Denmark))

    2009-08-15

    Overharmonic currents cause additional losses in the power supply network (lines, transformers) and in motors, which are supplied directly from the network (not motors, which are supplied from frequency converters or rectifiers). The overharmonic currents can be reduced or removed by capacitor banks and active filters. Active filters adjust themselves to the loading conditions and are also reacting on too slow transients and voltage disturbances in the network. Till now there is only little experience with active filters in commercial life. However, there are indications of potential electricity savings up to 10 % in installations with many overharmonic voltages (THDU > 5 %). The extent of harmonic distortions has been measured in 10 firms and has been compared to previous measurements. It is estimated that the voltage distortion, measured in THDU, at least must be 5 or 6 % in order to establish a profitable solution by reducing the harmonics by means of an active filter. In approx 40 % of the cases where the THDU has been measured, it has been estimated on the basis of THDU, current and utilization time that there is a potential of electricity savings by reducing the THDU. The overharmonic currents cause additional current heating losses in directly supplied motors as well as in lines and transformers. In induction motors they also cause current heating losses in the rotor and the 5th, 11th, 17th etc harmonics make a pulsating or reduced torque, which implies further losses. ABB and Comsys, both of which deliver active filters, have calculated electricity savings in some installations equipped with active filters. The direct electricity savings have been estimated at a low per cent in production equipment generally and up to 16 % in some directly supplied induction motors. In addition to the direct electricity savings the filters may also result in increased production capacity as a consequence of fewer breakdowns (the filters improve the voltage quality and

  14. Evaluation of energy savings potential of variable refrigerant flow (VRF from variable air volume (VAV in the U.S. climate locations

    Directory of Open Access Journals (Sweden)

    Dongsu Kim

    2017-11-01

    Full Text Available Variable refrigerant flow (VRF systems are known for their high energy performance and thus can improve energy efficiency both in residential and commercial buildings. The energy savings potential of this system has been demonstrated in several studies by comparing the system performance with conventional HVAC systems such as rooftop variable air volume systems (RTU-VAV and central chiller and boiler systems. This paper evaluates the performance of VRF and RTU-VAV systems in a simulation environment using widely-accepted whole building energy modeling software, EnergyPlus. A medium office prototype building model, developed by the U.S. Department of Energy (DOE, is used to assess the performance of VRF and RTU-VAV systems. Each system is placed in 16 different locations, representing all U.S. climate zones, to evaluate the performance variations. Both models are compliant with the minimum energy code requirements prescribed in ASHRAE standard 90.1-2010 — energy standard for buildings except low-rise residential buildings. Finally, a comparison study between the simulation results of VRF and RTU-VAV models is made to demonstrate energy savings potential of VRF systems. The simulation results show that the VRF systems would save around 15–42% and 18–33% for HVAC site and source energy uses compared to the RTU-VAV systems. In addition, calculated results for annual HVAC cost savings point out that hot and mild climates show higher percentage cost savings for the VRF systems than cold climates mainly due to the differences in electricity and gas use for heating sources.

  15. Measuring industrial energy savings

    International Nuclear Information System (INIS)

    Kelly Kissock, J.; Eger, Carl

    2008-01-01

    Accurate measurement of energy savings from industrial energy efficiency projects can reduce uncertainty about the efficacy of the projects, guide the selection of future projects, improve future estimates of expected savings, promote financing of energy efficiency projects through shared-savings agreements, and improve utilization of capital resources. Many efforts to measure industrial energy savings, or simply track progress toward efficiency goals, have had difficulty incorporating changing weather and production, which are frequently major drivers of plant energy use. This paper presents a general method for measuring plant-wide industrial energy savings that takes into account changing weather and production between the pre and post-retrofit periods. In addition, the method can disaggregate savings into components, which provides additional resolution for understanding the effectiveness of individual projects when several projects are implemented together. The method uses multivariable piece-wise regression models to characterize baseline energy use, and disaggregates savings by taking the total derivative of the energy use equation. Although the method incorporates search techniques, multi-variable least-squares regression and calculus, it is easily implemented using data analysis software, and can use readily available temperature, production and utility billing data. This is important, since more complicated methods may be too complex for widespread use. The method is demonstrated using case studies of actual energy assessments. The case studies demonstrate the importance of adjusting for weather and production between the pre- and post-retrofit periods, how plant-wide savings can be disaggregated to evaluate the effectiveness of individual retrofits, how the method can identify the time-dependence of savings, and limitations of engineering models when used to estimate future savings

  16. Building envelope regulations on thermal comfort in glass facade buildings and energy-saving potential for PMV-based comfort control

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, Ruey-Lung; Shu, Shiu-Ya [Department of Architecture, National United University, 1, Lien-Da, Kung-Ching Li, Miaoli, 36003 (China)

    2011-04-15

    This paper presents an investigation of the effect of building envelope regulation on thermal comfort and on the energy-saving potential for PMV-based comfort control in glass facade buildings. Occurrences and severity of overheating, based on the PMV-PPD model contained in ISO 7730, were used for the thermal comfort assessment. Parametric study simulations for an actual building with a large glass facade were carried out to predict the changes in thermal comfort levels in a space due to different glazing types, depths of overhang and glazing areas, which are the key parameters of the building envelope regulation index, named ENVLOAD, in Taiwan. The result demonstrates that the ENVLOAD has significant effect on thermal comfort. Additionally, comparative simulations between PMV-based comfort control and conventional thermostatic control were performed to investigate the changes in the energy-saving potential of a thermal comfort-controlled space due to changes of its ENVLOAD. The results demonstrate that the energy-saving potential in a PMV-based controlled space increases with low ENVLOAD conditions. (author)

  17. Projection potentials and angular momentum convergence of total energies in the full-potential Korringa–Kohn–Rostoker method

    International Nuclear Information System (INIS)

    Zeller, Rudolf

    2013-01-01

    Although the full-potential Korringa–Kohn–Rostoker Green function method yields accurate results for many physical properties, the convergence of calculated total energies with respect to the angular momentum cutoff is usually considered to be less satisfactory. This is surprising because accurate single-particle energies are expected if they are calculated by Lloyd’s formula and because accurate densities and hence accurate double-counting energies should result from the total energy variational principle. It is shown how the concept of projection potentials can be used as a tool to analyse the convergence behaviour. The key factor blocking fast convergence is identified and it is illustrated how total energies can be improved with only a modest increase of computing time. (paper)

  18. Use of total cross sections for obtaining the anisotropic interaction potential in atom--diatom system

    International Nuclear Information System (INIS)

    Eccles, J.; Secrest, D.

    1977-01-01

    A study is made of the ''conservation of the total cross section'' and the ''equivalence of the total cross section'' rules for scattering from H 2 . It is shown that these rules are a better approximation than the random phase approximation would indicate. Cross section formulas are given for scattering atoms from m/sub j/ state selected molecules and it is shown that total cross sections for state selected molecules depend on the anisotropic part of the interaction potential, while the spin-averaged total cross section often depends only on the spherically symmetric part of the interaction potential. The total spin-averaged cross section is thus independent of the initial rotation state of the molecule and depends only on the relative collision energy. It is further demonstrated that isotopic substitution, which shifts the center of mass changing the symmetric part of the interaction potential, has too small an effect on the total cross section to be useful as a means of determining the anisotropy of the potential

  19. Argon intermolecular potential from a measurement of the total scattering cross-section

    International Nuclear Information System (INIS)

    Wong, Y.W.

    1975-01-01

    An inversion method to obtain accurate intermolecular potentials from experimental total cross section measurements is presented. This method is based on the high energy Massey--Smith approximation. The attractive portion of the potential is represented by a multi-parameter spline function and the repulsive part by a Morse function. The best fit potential is obtained by a least squares minimization based on comparison of experimental cross sections with those obtained by a Fourier transform of the reduced Massey--Smith phase shift curve. An experimental method was developed to obtain the total cross sections needed for the above inversion procedure. In this technique, integral cross sections are measured at various resolutions and the total cross section is obtained by extrapolating to infinite resolution. Experimental results obtained for the Ar--Ar system are in excellent agreement with total cross sections calculated using the Barker-Fisher-Watts potential. Inversion of the data to obtain a potential distinguishable from the BFW-potential requires an extension of the method based on the Massey--Smith approximation to permit use of JWKB phase shifts and was not attempted

  20. Assessment of the Total Inflammatory Potential of Bioaerosols by Using a Granulocyte Assay▿

    OpenAIRE

    Timm, Michael; Madsen, Anne Mette; Hansen, Jørgen Vinsløv; Moesby, Lise; Hansen, Erik Wind

    2009-01-01

    Occupational health symptoms related to bioaerosol exposure have been observed in a variety of working environments. Bioaerosols contain microorganisms and microbial components. The aim of this study was to estimate the total inflammatory potential (TIP) of bioaerosols using an in vitro assay based on granulocyte-like cells. A total of 129 bioaerosol samples were collected in the breathing zone of workers during their daily working routine at 22 biofuel plants. The samples were analyzed by tr...

  1. Relativistic total energy and chemical potential of heavy atoms and positive ions

    International Nuclear Information System (INIS)

    Hill, S.H.; Grout, P.J.; March, N.H.

    1984-01-01

    The relativistic Thomas-Fermi theory, with a finite nucleus, is used to study the variation of the chemical potential μ with atomic number Z and number of electrons N (N <= Z). The difference between the total energy of positive ions and that of the corresponding neutral atom has been obtained. The scaling predictions are confirmed by numerical calculations. The first principles calculation of the relativistic Thomas-Fermi total energy of neutral atoms is also studied. (author)

  2. Net savings

    International Nuclear Information System (INIS)

    Roche, P.

    2001-01-01

    The state of e-commerce in the Canadian upstream oil and natural gas sector is examined in an effort to discover the extent to which the .com economy has penetrated the marketplace. The overall assessment is that although the situation varies from producer to producer and process to process, a bustling digital marketplace in the Canadian oil business has yet to emerge. Nevertheless, there are several examples of companies using e-business tools to minimize technology staffing and to eliminate wasteful practices. Initiatives cited include streamlining of supply chains to cut handling costs, using application service providers to trim information technology budgets, and adopting electronic joint interest billing to save on printing, postage and re-entering data. Most notable efforts have been made by companies such as BXL Energy Limited and Genesis Exploration Limited, both of which are boosting efficiency on the inside by contracting out data storage and software applications. For example, BXL has replaced its microfilm log library occupying six cabinets, and totalling about 9,000 lbs., by a fibre optic line. All applications can now be run from a laptop which weighs three to four pounds. In a similar vein, Genesis Exploration started using application service providers (ASPs) to avoid the cost and hassle of buying and maintaining major software applications in-house. By accessing the ASPs, Genesis staff can run software without buying or installing it on their own computers. In yet another example of cutting information technology costs, Pengrowth Corporation has its network administration done remotely over the Internet by Northwest Digital Systems (NWD). As far as the industry at large is concerned, the answer appears to be in a digital marketplace specifically tailored to the upstream sector's unique profile. As a start, a study is underway by Deloitte Consulting to explore producer interest in joining or founding an upstream digital marketplace. The study was

  3. Net savings

    Energy Technology Data Exchange (ETDEWEB)

    Roche, P.

    2001-02-01

    The state of e-commerce in the Canadian upstream oil and natural gas sector is examined in an effort to discover the extent to which the .com economy has penetrated the marketplace. The overall assessment is that although the situation varies from producer to producer and process to process, a bustling digital marketplace in the Canadian oil business has yet to emerge. Nevertheless, there are several examples of companies using e-business tools to minimize technology staffing and to eliminate wasteful practices. Initiatives cited include streamlining of supply chains to cut handling costs, using application service providers to trim information technology budgets, and adopting electronic joint interest billing to save on printing, postage and re-entering data. Most notable efforts have been made by companies such as BXL Energy Limited and Genesis Exploration Limited, both of which are boosting efficiency on the inside by contracting out data storage and software applications. For example, BXL has replaced its microfilm log library occupying six cabinets, and totalling about 9,000 lbs., by a fibre optic line. All applications can now be run from a laptop which weighs three to four pounds. In a similar vein, Genesis Exploration started using application service providers (ASPs) to avoid the cost and hassle of buying and maintaining major software applications in-house. By accessing the ASPs, Genesis staff can run software without buying or installing it on their own computers. In yet another example of cutting information technology costs, Pengrowth Corporation has its network administration done remotely over the Internet by Northwest Digital Systems (NWD). As far as the industry at large is concerned, the answer appears to be in a digital marketplace specifically tailored to the upstream sector's unique profile. As a start, a study is underway by Deloitte Consulting to explore producer interest in joining or founding an upstream digital marketplace. The study

  4. Forecasting the demand on solar water heating systems and their energy savings potential during the period 2001-2005 in Jordan

    International Nuclear Information System (INIS)

    Kablan, M.M.

    2003-01-01

    Jordan is an example of a developing country that depends almost exclusively on imported oil. Luckily, Jordan is blessed with good solar energy resources. However, only 24% of Jordanian families are installing solar water heating systems (SWHS). The objective of this research is to forecast the yearly demand on SWHS by the household sector during the period 2001-2005 and to compute the potential energy savings throughout the investigated period due to the use of SWHS. It is found that the net energy collected over the entire investigated period is about 1454.4 million kW h. In addition, the capital savings over the entire investigated period is estimated to be 46.28 million US$ if SWHS are used to heat water instead of the commonly used LPG gas cookers. The results of the research may assist decision makers in the energy sector to implement more comprehensive plans that encourage more families to install SWHS and save on imported oil

  5. Cost-of-illness analysis reveals potential healthcare savings with reductions in type 2 diabetes and cardiovascular disease following recommended intakes of dietary fibre in Canada

    Directory of Open Access Journals (Sweden)

    Mohammad eAbdullah

    2015-08-01

    Full Text Available Background: Consumption of fibre-rich diets is associated with favourable impacts on type 2 diabetes (T2D and cardiovascular disease (CVD, two of the most costly ailments worldwide, however the economic value of altered fibre intakes remains poorly understood. Methods: A cost-of-illness analysis was conducted to identify the percentage of adults expected to consume fibre-rich diets in Canada, estimate fibre intakes in relation to T2D and CVD reductions, and assess the potential annual savings in healthcare costs with reductions in rates of these two epidemics. Results: Non-trivial healthcare and related savings of CAD$35.9-$718.8 million in T2D costs and CAD$64.8-$1,295.7 million in CVD costs were calculated under a scenario where cereal fibre was used to increase current intakes of dietary fibre to the recommended levels of 38 g per day for men and 25 g per day for women. Each 1 g per day increase in fibre consumption resulted in annual CAD$2.6-$51.1 and $4.6-$92.1 million savings for T2D and CVD, respectively. Conclusions: Strategies to increase consumers’ knowledge of the recommended dietary fibre intakes, as part of healthy diet, and to facilitate stakeholder synergy are warranted to enable better management of costs associated with T2D and CVD in Canada.

  6. Anti-tumor potential of total alkaloid extract of Prosopis juliflora DC ...

    African Journals Online (AJOL)

    The total alkaloid extract from Prosopis juliflora DC. leaves was obtained using acid/base modified extraction method. The in vitro anti-tumor potential of the extract was evaluated using MTT (3-(4,5- dimethythiazol-2yl)2,5-diphenyl tetrazolium bromide) based cytotoxicity monitoring after 24, 48 and 72 h exposure of the ...

  7. Reevaluation of Vitrified High-Level Waste Form Criteria for Potential Cost Savings at the Defense Waste Processing Facility - 13598

    Energy Technology Data Exchange (ETDEWEB)

    Ray, J.W. [Savannah River Remediation (United States); Marra, S.L.; Herman, C.C. [Savannah River National Laboratory, Savannah River Site, Aiken, SC 29808 (United States)

    2013-07-01

    At the Savannah River Site (SRS) the Defense Waste Processing Facility (DWPF) has been immobilizing SRS's radioactive high level waste (HLW) sludge into a durable borosilicate glass since 1996. Currently the DWPF has poured over 3,500 canisters, all of which are compliant with the U. S. Department of Energy's (DOE) Waste Acceptance Product Specifications for Vitrified High-Level Waste Forms (WAPS) and therefore ready to be shipped to a federal geologic repository for permanent disposal. Due to DOE petitioning to withdraw the Yucca Mountain License Application (LA) from the Nuclear Regulatory Commission (NRC) in 2010 and thus no clear disposal path for SRS canistered waste forms, there are opportunities for cost savings with future canister production at DWPF and other DOE producer sites by reevaluating high-level waste form requirements and compliance strategies and reducing/eliminating those that will not negatively impact the quality of the canistered waste form. (authors)

  8. Reevaluation Of Vitrified High-Level Waste Form Criteria For Potential Cost Savings At The Defense Waste Processing Facility

    International Nuclear Information System (INIS)

    Ray, J. W.; Marra, S. L.; Herman, C. C.

    2013-01-01

    At the Savannah River Site (SRS) the Defense Waste Processing Facility (DWPF) has been immobilizing SRS's radioactive high level waste (HLW) sludge into a durable borosilicate glass since 1996. Currently the DWPF has poured over 3,500 canisters, all of which are compliant with the U. S. Department of Energy's (DOE) Waste Acceptance Product Specifications for Vitrified High-Level Waste Forms (WAPS) and therefore ready to be shipped to a federal geologic repository for permanent disposal. Due to DOE petitioning to withdraw the Yucca Mountain License Application (LA) from the Nuclear Regulatory Commission (NRC) in 2010 and thus no clear disposal path for SRS canistered waste forms, there are opportunities for cost savings with future canister production at DWPF and other DOE producer sites by reevaluating high-level waste form requirements and compliance strategies and reducing/eliminating those that will not negatively impact the quality of the canistered waste form

  9. Long term energy demand projection and potential for energy savings of Croatian tourism–catering trade sector

    International Nuclear Information System (INIS)

    Irsag, Bojan; Pukšec, Tomislav; Duić, Neven

    2012-01-01

    Today, tourism represents one of the backbones of Croatian economy and one of the main factors of its growth. Combined with catering trade sector, tourism represents a significant energy consumer that has the tendencies of future growth. Since services sector, which tourism–catering trade sector is a part of, is not yet well described regarding future energy balances it would be very interesting to see how could possible future growth in tourism influence energy consumption of the services sector in Croatia. Through this paper long term energy demand projections of tourism–catering trade sector were studied with special emphasis on future growth of tourism in Croatia as well as different mechanisms that might lead to certain energy savings. Bottom-up approach was chosen as the most suitable one since it allows better quantification of different measures, technological or legal, that would influence future energy demand. Downside of this approach is extensive input data that is required to analyse and model future energy demand which is roughly divided into heating/cooling section and all other consumption. Results show that additional energy savings in the tourism–catering trade sector are possible if careful and rational demand side planning is in place. -- Highlights: ► Future energy demand of Croatian touristm–catering trade sector has been modelled. ► Model is roughly divided into two basic modes (heating/cooling and all other consumption). ► Different factors influencing future energy demand were implemented into the model. ► Possibilities for energy efficiency improvements have been presented.

  10. Improved methods to evaluate realised energy savings

    NARCIS (Netherlands)

    Boonekamp, P.G.M.

    2005-01-01

    This thesis regards the calculation of realised energy savings at national and sectoral level, and the policy contribution to total savings. It is observed that the results of monitoring and evaluation studies on realised energy savings are hardly applied in energy saving policy. Causes are the lack

  11. In-office diagnostic arthroscopy for knee and shoulder intra-articular injuries its potential impact on cost savings in the United States

    Science.gov (United States)

    2014-01-01

    Background The purpose of this analysis was to determine whether in office diagnostic needle arthroscopy (Visionscope Imaging System [VSI]) can provide for improved diagnostic assessment and; more cost effective care. Methods Data on arthroscopy procedures in the US for deep seated pathology in the knee and shoulder were used (Calendar Year 2012). These procedures represent approximately 25-30% of all arthroscopic procedures performed annually. Sensitivities, specificities, positive predictive, and negative predictive values for MRI analysis of this deep seated pathology from systematic reviews and meta-analyses were used in assessing for false positive and false negative MRI findings. The costs of performing diagnostic and surgical arthroscopy procedures (using 2013 Medicare reimbursement amounts); costs associated with false negative findings; and the costs for treating associated complications arising from diagnostic and therapeutic arthroscopy procedures were then assessed. Results In patients presenting with medial meniscal pathology (ICD9CM diagnosis 836.0 over 540,000 procedures in CY 2012); use of the VSI system in place of MRI assessment (standard of care) resulted in a net cost savings to the system of $151 million. In patients presenting with rotator cuff pathology (ICD9CM 840.4 over 165,000 procedures in CY2012); use of VSI in place of MRI similarly saved $59 million. These savings were realized along with more appropriate care as; fewer patients were exposed to higher risk surgical arthroscopic procedures. Conclusions The use of an in-office arthroscopy system can: possibly save the US healthcare system money; shorten the diagnostic odyssey for patients; potentially better prepare clinicians for arthroscopic surgery (when needed) and; eliminate unnecessary outpatient arthroscopy procedures, which commonly result in surgical intervention. PMID:24885678

  12. Numerical investigation of the energy saving potential of a semi-transparent photovoltaic double-skin facade in a cool-summer Mediterranean climate

    International Nuclear Information System (INIS)

    Peng, Jinqing; Curcija, Dragan C.; Lu, Lin; Selkowitz, Stephen E.; Yang, Hongxing; Zhang, Weilong

    2016-01-01

    Highlights: • A comprehensive simulation model has been developed to predict the overall energy performance of PV-DSF. • Sensitivity analyses of air gap depths were conducted and the optimal air gap depth was identified. • The overall energy performance and energy saving potential of the PV-DSF was evaluated. • A comparative study was conducted between the PV-DSF and other commonly used window technologies. - Abstract: This paper presents the annual overall energy performance and energy-saving potential of a ventilated photovoltaic double-skin facade (PV-DSF) in a cool-summer Mediterranean climate zone. A numerical simulation model based on EnergyPlus was utilized to simulate the PV-DSF overall energy performance, simultaneously taking into account thermal power and daylight. Based on numerical model, sensitivity analyses about air gap width and ventilation modes have been lead in Berkeley (California) with the aim to optimize unit’s structure design and operational strategy of PV-DSF. Via simulation, the overall energy performance including thermal, power and daylighting of the optimized PV-DSF was evaluated using the typical meteorological year (TMY) weather data. It was found that per unit area of the proposed PV-DSF was able to generate about 65 kW h electricity yearly. If high efficiency cadmium telluride (CdTe) semi-transparent PV modules are adopted, the annual energy output could be even doubled. The PV-DSF studied, also featured good thermal and daylighting performances. The PV-DSF can effectively block solar radiation while still providing considerable daylighting illuminance. Due simply to excellent overall energy performance, a PV-DSF at Berkeley can reduce net electricity use by about 50% compared with other commonly used glazing systems. Efficiency improvements of semi-transparent PV modules would further increase the energy saving potential of a PV-DSF and thus making this technology more promising.

  13. Creation of Carbon Credits by Water Saving

    Directory of Open Access Journals (Sweden)

    Yasutoshi Shimizu

    2012-07-01

    Full Text Available Until now, as a way of reducing greenhouse gas emissions from Japanese homes, the emphasis has been on reduction of energy consumption for air-conditioning and lighting. In recent years, there has been progress in CO2 emission reduction through research into the water-saving performance of bathroom fixtures such as toilets and showers. Simulations have shown that CO2 emissions associated with water consumption in Japanese homes can be reduced by 25% (1% of Japan’s total CO2 emissions by 2020 through the adoption of the use of water-saving fixtures. In response to this finding, a program to promote the replacement of current fixtures with water-saving toilet bowls and thermally insulated bathtubs has been added to the Government of Japan’s energy-saving policy. Furthermore, CO2 emission reduction through widespread use of water-saving fixtures has been adopted by the domestic credit system promoted by the Government of Japan as a way of achieving CO2 emission-reduction targets; application of this credit system has also begun. As part of a bilateral offset credit mechanism promoted by the Government of Japan, research to evaluate the CO2 reduction potential of the adoption of water-saving fixtures has been done in the city of Dalian, in China.

  14. Cost-of-illness analysis reveals potential healthcare savings with reductions in type 2 diabetes and cardiovascular disease following recommended intakes of dietary fiber in Canada

    Science.gov (United States)

    Abdullah, Mohammad M. H.; Gyles, Collin L.; Marinangeli, Christopher P. F.; Carlberg, Jared G.; Jones, Peter J. H.

    2015-01-01

    Background: Type 2 diabetes (T2D) and cardiovascular disease (CVD) are leading causes of mortality and two of the most costly diet-related ailments worldwide. Consumption of fiber-rich diets has been repeatedly associated with favorable impacts on these co-epidemics, however, the healthcare cost-related economic value of altered dietary fiber intakes remains poorly understood. In this study, we estimated the annual cost savings accruing to the Canadian healthcare system in association with reductions in T2D and CVD rates, separately, following increased intakes of dietary fiber by adults. Methods: A three-step cost-of-illness analysis was conducted to identify the percentage of individuals expected to consume fiber-rich diets in Canada, estimate increased fiber intakes in relation to T2D and CVD reduction rates, and independently assess the potential annual savings in healthcare costs associated with the reductions in rates of these two epidemics. The economic model employed a sensitivity analysis of four scenarios (universal, optimistic, pessimistic, and very pessimistic) to cover a range of assumptions within each step. Results: Non-trivial healthcare and related savings of CAD$35.9-$718.8 million in T2D costs and CAD$64.8 million–$1.3 billion in CVD costs were calculated under a scenario where cereal fiber was used to increase current intakes of dietary fiber to the recommended levels of 38 g per day for men and 25 g per day for women. Each 1 g per day increase in fiber consumption resulted in annual CAD$2.6 to $51.1 million savings for T2D and $4.6 to $92.1 million savings for CVD. Conclusion: Findings of this analysis shed light on the economic value of optimal dietary fiber intakes. Strategies to increase consumers’ general knowledge of the recommended intakes of dietary fiber, as part of healthy diet, and to facilitate stakeholder synergy are warranted to enable better management of healthcare and related costs associated with T2D and CVD in Canada. PMID

  15. Medical Care Expenditures for Individuals with Prediabetes: The Potential Cost Savings in Reducing the Risk of Developing Diabetes.

    Science.gov (United States)

    Khan, Tamkeen; Tsipas, Stavros; Wozniak, Gregory

    2017-10-01

    The United States has 86 million adults with prediabetes. Individuals with prediabetes can prevent or delay the development of type 2 diabetes through lifestyle modifications such as participation in the National Diabetes Prevention Program (DPP), thereby mitigating the medical and economic burdens associated with diabetes. A cohort analysis of a commercially insured population was conducted using individual-level claims data from Truven Health MarketScan ® Lab Database to identify adults with prediabetes, track whether they develop diabetes, and compare medical expenditures for those who are newly diagnosed with diabetes to those who are not. This study then illustrates how reducing the risk of developing diabetes by participation in an evidence-based lifestyle change program could yield both positive net savings on medical care expenditures and return on investment (ROI). Annual expenditures are found to be nearly one third higher for those who develop diabetes in subsequent years relative to those who do not transition from prediabetes to diabetes, with an average difference of $2671 per year. At that cost differential, the 3-year ROI for a National DPP is estimated to be as high as 42%. The results show the importance and economic benefits of participation in lifestyle intervention programs to prevent or delay the onset of type 2 diabetes.

  16. Calculation of direct antiretroviral treatment costs and potential cost savings by using generics in the German HIV ClinSurv cohort.

    Directory of Open Access Journals (Sweden)

    Matthias Stoll

    Full Text Available UNLABELLED: BACKGROUND/AIM OF THE STUDY: The study aimed to determine the cost impacts of antiretroviral drugs by analysing a long-term follow-up of direct costs for combined antiretroviral therapy, cART, -regimens in the nationwide long-term observational multi-centre German HIV ClinSurv Cohort. The second aim was to develop potential cost saving strategies by modelling different treatment scenarios. METHODS: Antiretroviral regimens (ART from 10,190 HIV-infected patients from 11 participating ClinSurv study centres have been investigated since 1996. Biannual data cART-initiation, cART-changes, surrogate markers, clinical events and the Centre of Disease Control- (CDC-stage of HIV disease are reported. Treatment duration was calculated on a daily basis via the documented dates for the beginning and end of each antiretroviral drug treatment. Prices were calculated for each individual regimen based on actual office sales prices of the branded pharmaceuticals distributed by the license holder including German taxes. RESULTS: During the 13-year follow-up period, 21,387,427 treatment days were covered. Cumulative direct costs for antiretroviral drugs of €812,877,356 were determined according to an average of €42.08 per day (€7.52 to € 217.70. Since cART is widely used in Germany, the costs for an entire regimen increased by 13.5%. Regimens are more expensive in the advanced stages of HIV disease. The potential for cost savings was calculated using non-nucleotide-reverse-transcriptase-inhibitor, NNRTI, more frequently instead of ritonavir-boosted protease inhibitor, PI/r, in first line therapy. This calculation revealed cumulative savings of 10.9% to 19.8% of daily treatment costs (50% and 90% substitution of PI/r, respectively. Substituting certain branded drugs by generic drugs showed potential cost savings of between 1.6% and 31.8%. CONCLUSIONS: Analysis of the data of this nationwide study reflects disease-specific health services research

  17. Calculation of direct antiretroviral treatment costs and potential cost savings by using generics in the German HIV ClinSurv cohort.

    Science.gov (United States)

    Stoll, Matthias; Kollan, Christian; Bergmann, Frank; Bogner, Johannes; Faetkenheuer, Gerd; Fritzsche, Carlos; Hoeper, Kirsten; Horst, Heinz-August; van Lunzen, Jan; Plettenberg, Andreas; Reuter, Stefan; Rockstroh, Jürgen; Stellbrink, Hans-Jürgen; Hamouda, Osamah; Bartmeyer, Barbara

    2011-01-01

    BACKGROUND/AIM OF THE STUDY: The study aimed to determine the cost impacts of antiretroviral drugs by analysing a long-term follow-up of direct costs for combined antiretroviral therapy, cART, -regimens in the nationwide long-term observational multi-centre German HIV ClinSurv Cohort. The second aim was to develop potential cost saving strategies by modelling different treatment scenarios. Antiretroviral regimens (ART) from 10,190 HIV-infected patients from 11 participating ClinSurv study centres have been investigated since 1996. Biannual data cART-initiation, cART-changes, surrogate markers, clinical events and the Centre of Disease Control- (CDC)-stage of HIV disease are reported. Treatment duration was calculated on a daily basis via the documented dates for the beginning and end of each antiretroviral drug treatment. Prices were calculated for each individual regimen based on actual office sales prices of the branded pharmaceuticals distributed by the license holder including German taxes. During the 13-year follow-up period, 21,387,427 treatment days were covered. Cumulative direct costs for antiretroviral drugs of €812,877,356 were determined according to an average of €42.08 per day (€7.52 to € 217.70). Since cART is widely used in Germany, the costs for an entire regimen increased by 13.5%. Regimens are more expensive in the advanced stages of HIV disease. The potential for cost savings was calculated using non-nucleotide-reverse-transcriptase-inhibitor, NNRTI, more frequently instead of ritonavir-boosted protease inhibitor, PI/r, in first line therapy. This calculation revealed cumulative savings of 10.9% to 19.8% of daily treatment costs (50% and 90% substitution of PI/r, respectively). Substituting certain branded drugs by generic drugs showed potential cost savings of between 1.6% and 31.8%. Analysis of the data of this nationwide study reflects disease-specific health services research and will give insights into the cost impacts of

  18. Effect of imaginary part of an optical potential on reaction total cross sections

    International Nuclear Information System (INIS)

    Afanas'ev, G.N.; Dobromyslov, M.B.; Kim Yng Pkhung; Shilov, V.M.

    1977-01-01

    The effect of the imaginary part of optical potential on the total cross sections of reactions is explained. The complex rectangular well model is used, i.e. the real rectangular well at r 16 O + 27 Al reactions and the partial permeabilities are presented. It is demonstrated that the S-matrix has proved to be unitary. Oscillations of the partial permeabilities and cross-sections are observed for small potential values in the Wsub(o) imaginary part, which no longer occur at larger Wsub(o). This corresponds to the overlapping and nonoverlapping quasistationary levels in complex rectangular well

  19. Scenario analysis of energy saving and CO_2 emissions reduction potentials to ratchet up Japanese mitigation target in 2030 in the residential sector

    International Nuclear Information System (INIS)

    Wakiyama, Takako; Kuramochi, Takeshi

    2017-01-01

    This paper assesses to what extent CO_2 emissions from electricity in the residential sector can be further reduced in Japan beyond its post-2020 mitigation target (known as “Intended Nationally Determined Contribution (INDC)”). The paper examines the reduction potential of electricity demand and CO_2 emissions in the residential sector by conducting a scenario analysis. Electricity consumption scenarios are set up using a time-series regression model, and used to forecast the electricity consumption patterns to 2030. The scenario analysis also includes scenarios that reduce electricity consumption through enhanced energy efficiency and energy saving measures. The obtained results show that Japan can reduce electricity consumption and CO_2 emissions in the residential sector in 2030 more than the Japanese post-2020 mitigation target indicates. At the maximum, the electricity consumption could be reduced by 35 TWh, which contributes to 55.4 MtCO_2 of emissions reduction in 2030 compared to 2013 if the voluntarily targeted CO_2 intensity of electricity is achieved. The result implies that Japan has the potential to ratchet up post-2020 mitigation targets discussed under the Paris Agreement of the United Nations Framework Convention on Climate Change (UNFCCC). - Highlights: • Further reduction of electricity consumption is possible beyond Japan's post-2020 mitigation target. • Energy saving efforts by households and incentives to reduce electricity demands are required. • Improvement of CO_2 intensity from electricity is a key factor in the reduction of CO_2 emissions.

  20. The use of total detriment in radiation protection and its potential extension to other hazards

    International Nuclear Information System (INIS)

    Johnson, J.R.; Stansbury, P.S.; Selby, J.M.

    1991-10-01

    Before publication of the 1977 recommendations of the International Commission on Radiological Protection (ICRP), radiation protection standards were based on dose limits to single organs. These dose limits were only loosely linked to the expected effects in the first two generations from gonadal doses and to the risk of fatal cancer from doses to specific organs. In 1977, the ICRP recommended the use of the ''effective dose equivalent (EDE),'' which is a method of summing the doses (weighted with relative risk coefficients) to all organs and tissues, and recommended an annual limit for EDE. Since the 1977 recommendations were published, a ''total risk'' or total detriment approach has been extended to include nonfatal cancers and genetic effects for all subsequent generations, i.e., the total health detriment from low doses of ionizing radiation. This paper discusses the development of this total health detriment from ionizing radiation exposures, and explores potential methods for using it with other hazards (such as exposures to other physical agents, hazardous chemicals, and fatal and nonfatal accidents) in calculating the total detriment to a worker

  1. Biomass energy in Jordan, and its potential contribution towards the total energy mix of the Kingdom

    International Nuclear Information System (INIS)

    Al-Dabbas, Moh'd A. F.

    1994-04-01

    An evaluation of Jordan's bio-energy status was carried out. Available sources and the viability of exploitation were studied in order to identify the size of contribution that bio-energy could provide to the total energy mix of the Kingdom. The advantages of biogas technology were discussed, and a general description of Jordan's experience in this field was presented. Data on Jordan' animal, municipal, and agricultural wastes that are available as a potential source of bio-energy was tabulated. The report ascertained the economic feasibility of biogas utilization in Jordan, and concluded that the annual energy production potential from biogas, with only animal wastes being utilized, would amount to 80,000 ton oil equivalent. This amount of energy is equivalent to 2% of Jordan's total energy consumption in 1992. The utilization of biogas from municipal wastes would produce an additional 2.5% of the total energy consumption of Jordan. The annual value of utilizing animal and municipal wastes would reach 23 million Jordanian Dinars (JD). This value would increase to 61.5 million JD with the utilization of human wastes. The investment required for the utilization of bio-energy sources in Amman and its suburbs on the scale of family unit fermenters was estimated to be in the order of a million JD. The size of investment for industrial scale utilization for power generation with an electricity feed to the national grid, would range from 3 to 4 million JD. (A.M.H.). 8 refs., 4 tabs

  2. Total System Performance Assessment, 1993: An evaluation of the potential Yucca Mountain repository

    International Nuclear Information System (INIS)

    Andrews, R.W.; Dale, T.F.; McNeish, J.A.

    1994-03-01

    Total System Performance Assessments are an important component in the evaluation of the suitability of Yucca Mountain, Nevada as a potential site for a mined geologic repository for the permanent disposal of high-level radioactive wastes in the United States. The Total System Performance Assessments are conducted iteratively during site characterization to identify issues which should be addressed by the characterization and design activities as well as providing input to regulatory/licensing and programmatic decisions. During fiscal years 1991 and 1992, the first iteration of Total System Performance Assessment (hereafter referred to as TSPA 1991) was completed by Sandia National Laboratories and Pacific Northwest Laboratory. Beginning in fiscal year 1993, the Civilian Radioactive Waste Management System Management and Operating Contractor was assigned the responsibility to plan, coordinate, and contribute to the second iteration of Total System Performance Assessment (hereafter referred to as TSPA 1993). This document presents the objectives, approach, assumptions, input, results, conclusions, and recommendations associated with the Management and Operating Contractor contribution to TSPA 1993. The new information incorporated in TSPA 1993 includes (1) revised estimates of radionuclide solubilities (and their thermal and geochemical dependency), (2) thermal and geochemical dependency of spent fuel waste alteration and glass dissolution rates, (3) new distribution coefficient (k d ) estimates, (4) revised estimates of gas-phase velocities and travel times, and (5) revised hydrologic modeling of the saturated zone which provides updated estimates of the advective flux through the saturated zone

  3. Total System Performance Assessment, 1993: An evaluation of the potential Yucca Mountain repository

    Energy Technology Data Exchange (ETDEWEB)

    Andrews, R.W.; Dale, T.F.; McNeish, J.A.

    1994-03-01

    Total System Performance Assessments are an important component in the evaluation of the suitability of Yucca Mountain, Nevada as a potential site for a mined geologic repository for the permanent disposal of high-level radioactive wastes in the United States. The Total System Performance Assessments are conducted iteratively during site characterization to identify issues which should be addressed by the characterization and design activities as well as providing input to regulatory/licensing and programmatic decisions. During fiscal years 1991 and 1992, the first iteration of Total System Performance Assessment (hereafter referred to as TSPA 1991) was completed by Sandia National Laboratories and Pacific Northwest Laboratory. Beginning in fiscal year 1993, the Civilian Radioactive Waste Management System Management and Operating Contractor was assigned the responsibility to plan, coordinate, and contribute to the second iteration of Total System Performance Assessment (hereafter referred to as TSPA 1993). This document presents the objectives, approach, assumptions, input, results, conclusions, and recommendations associated with the Management and Operating Contractor contribution to TSPA 1993. The new information incorporated in TSPA 1993 includes (1) revised estimates of radionuclide solubilities (and their thermal and geochemical dependency), (2) thermal and geochemical dependency of spent fuel waste alteration and glass dissolution rates, (3) new distribution coefficient (k{sub d}) estimates, (4) revised estimates of gas-phase velocities and travel times, and (5) revised hydrologic modeling of the saturated zone which provides updated estimates of the advective flux through the saturated zone.

  4. A retrospective analysis of the duration of oral antibiotic therapy for the treatment of acne among adolescents: investigating practice gaps and potential cost-savings.

    Science.gov (United States)

    Lee, Young H; Liu, Guodong; Thiboutot, Diane M; Leslie, Douglas L; Kirby, Joslyn S

    2014-07-01

    Duration of oral antibiotic therapy in acne has not been widely studied. Recent guidelines suggest it should be limited to 3 to 6 months. We sought to compare the duration of oral antibiotic use with recent guidelines and determine the potential cost-savings related to shortened durations. This is a retrospective cohort study from the MarketScan Commercial Claims and Encounters database. Claims data were used to determine duration and costs of antibiotic therapy. The mean course duration was 129 days. The majority (93%) of courses were less than 9 months. Among the 31,634 courses, 18,280 (57.8%) did not include concomitant topical retinoid therapy. The mean (95% confidence interval) duration with and without topical retinoid use was 133 (131.5-134.7) days and 127 (125.4-127.9) days, respectively. The mean excess direct cost of antibiotic treatment for longer than 6 months was $580.99/person. Claims cannot be attributed to a specific diagnosis or provider. The database does not provide information on acne severity. Duration of antibiotic use is decreasing when compared with previous data. However, 5547 (17.53%) courses exceeded 6 months, highlighting an opportunity for reduced antibiotic use. If courses greater than 6 months were shortened to 6 months, savings would be $580.99/person. Copyright © 2014 American Academy of Dermatology, Inc. Published by Mosby, Inc. All rights reserved.

  5. Potential cost savings by minimisation of blood sample delays on care decision making in urgent care services

    Directory of Open Access Journals (Sweden)

    David M.S. Bodansky

    2017-08-01

    Conclusion: Sample rejection rate is high and is associated with increased in-hospital stay and cost. Blood sampling technique impacts on rejection rates. Reduction in sample rejection rates in emergency care areas in acute hospitals has the potential to impact on patient flow and reduce cost.

  6. Using learning curves on energy-efficient technologies to estimate future energy savings and emission reduction potentials in the U.S. iron and steel industry

    Energy Technology Data Exchange (ETDEWEB)

    Karali, Nihan [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Park, Won Young [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); McNeil, Michael A. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2015-06-18

    Increasing concerns on non-sustainable energy use and climate change spur a growing research interest in energy efficiency potentials in various critical areas such as industrial production. This paper focuses on learning curve aspects of energy efficiency measures in the U.S iron and steel sector. A number of early-stage efficient technologies (i.e., emerging or demonstration technologies) are technically feasible and have the potential to make a significant contribution to energy saving and CO2 emissions reduction, but fall short economically to be included. However, they may also have the cost effective potential for significant cost reduction and/or performance improvement in the future under learning effects such as ‘learning-by-doing’. The investigation is carried out using ISEEM, a technology oriented, linear optimization model. We investigated how steel demand is balanced with/without the availability learning curve, compared to a Reference scenario. The retrofit (or investment in some cases) costs of energy efficient technologies decline in the scenario where learning curve is applied. The analysis also addresses market penetration of energy efficient technologies, energy saving, and CO2 emissions in the U.S. iron and steel sector with/without learning impact. Accordingly, the study helps those who use energy models better manage the price barriers preventing unrealistic diffusion of energy-efficiency technologies, better understand the market and learning system involved, predict future achievable learning rates more accurately, and project future savings via energy-efficiency technologies with presence of learning. We conclude from our analysis that, most of the existing energy efficiency technologies that are currently used in the U.S. iron and steel sector are cost effective. Penetration levels increases through the years, even though there is no price reduction. However, demonstration technologies are not economically

  7. Real-space formulation of the electrostatic potential and total energy of solids

    International Nuclear Information System (INIS)

    Pask, J E; Sterne, P A

    2004-01-01

    We develop expressions for the electrostatic potential and total energy of crystalline solids which are amenable to direct evaluation in real space. Unlike conventional reciprocal space formulations, no Fourier transforms or reciprocal lattice summations are required, and the formulation is well suited for large-scale, parallel computations. The need for reciprocal space expressions is eliminated by replacing long-range potentials by equivalent localized charge distributions and incorporating long-range interactions into boundary conditions on the unit cell. In so doing, a simplification of the conventional reciprocal space formalism is obtained. The equivalence of the real- and reciprocal space formalisms is demonstrated by direct comparison in self-consistent density-functional calculations

  8. Total system performance assessment - 1995: An evaluation of the potential Yucca Mountain repository

    Energy Technology Data Exchange (ETDEWEB)

    Atkins, J.E.; Lee, J.H.; Lingineni, S.; Mishra, S; McNeish, J.A.; Sassani, D.C.; Sevougian, S.D.

    1995-11-01

    The U.S. Department of Energy (DOE) is currently investigating the feasibility of permanently disposing the nation`s commercial high-level radioactive wastes (in the form of spent fuel from the over 100 electric power-generating nuclear reactors across the U.S.) and a portion of the defense high-level radioactive wastes (currently stored at federal facilities around the country) in the unsaturated tuffaceous rocks at Yucca Mountain, Nevada. Quantitative predictions based on the most current understanding of the processes and parameters potentially affecting the long-term behavior of the disposal system are used to assess the ability of the site and its associated engineered designs to meet regulatory objectives of the US NRC and the US EPA. The evaluation of the ability of the overall system to meet the performance objectives specified in the applicable regulatory standards has been termed total system performance assessment (TSPA). Total system performance assessments require the explicit quantification of the relevant processes and process interactions. In addition assessments are useful to help define the most significant processes, the information gaps and uncertainties and therefore the additional information required for more robust and defensible assessment of the overall performance. The aim of any total system performance assessment is to be as complete and reasonably conservative as possible and to assure that the descriptions of the predictive models and parameters are sufficient to ascertain their accuracy. Total system performance assessments evolve with time. Previous iterations of total system performance assessment of the Yucca Mountain site and associated engineered barriers have been conducted in 1991 and 1993.

  9. Total system performance assessment - 1995: An evaluation of the potential Yucca Mountain repository

    International Nuclear Information System (INIS)

    Atkins, J.E.; Lee, J.H.; Lingineni, S.; Mishra, S.; McNeish, J.A.; Sassani, D.C.; Sevougian, S.D.

    1995-11-01

    The U.S. Department of Energy (DOE) is currently investigating the feasibility of permanently disposing the nation's commercial high-level radioactive wastes (in the form of spent fuel from the over 100 electric power-generating nuclear reactors across the U.S.) and a portion of the defense high-level radioactive wastes (currently stored at federal facilities around the country) in the unsaturated tuffaceous rocks at Yucca Mountain, Nevada. Quantitative predictions based on the most current understanding of the processes and parameters potentially affecting the long-term behavior of the disposal system are used to assess the ability of the site and its associated engineered designs to meet regulatory objectives of the US NRC and the US EPA. The evaluation of the ability of the overall system to meet the performance objectives specified in the applicable regulatory standards has been termed total system performance assessment (TSPA). Total system performance assessments require the explicit quantification of the relevant processes and process interactions. In addition assessments are useful to help define the most significant processes, the information gaps and uncertainties and therefore the additional information required for more robust and defensible assessment of the overall performance. The aim of any total system performance assessment is to be as complete and reasonably conservative as possible and to assure that the descriptions of the predictive models and parameters are sufficient to ascertain their accuracy. Total system performance assessments evolve with time. Previous iterations of total system performance assessment of the Yucca Mountain site and associated engineered barriers have been conducted in 1991 and 1993

  10. Further potential savings attributable to maximum generic substitution of antidepressants in South Africa: A retrospective analysis of medical claims

    Directory of Open Access Journals (Sweden)

    Elmarie van der Westhuizen

    2010-11-01

    Opsomming Die hoofmikpunt van hierdie studie was om die potensiële kostebesparing te bereken wat deur maksimale generiese vervanging van antidepressante in die Suid-Afrikaanse private gesondheidsorgsektor tussen 2004 en 2006 teweeggebring sou kon word. Data oor gerekenariseerde eise vir medisyne van pasiënte wat een of meer antidepressante gedurende die studietydperk ontvang het (d.i. 2004, 2005 en 2006 is van ʼn Suid-Afrikaanse maatskappy wat farmaseutiese voordele bestuur, verkry. Die totale studiepopulasie het bestaan uit 292 071 items (N = 5 982 869van 273 673 voorskrifte (N = 5 213 765 teen ʼn totale koste van R56 183 697.91 (N = R1 346 210 929.00.’n Kwantitatiewe, retrospektiewe medisyneverbruiksontleding is gedoen en data is geanaliseer deur van die Statistical Analysis System®-pakket gebruik te maak. Potensiële kostebesparings is vir middels in die studiepopulasie wat aan die kriteria voldoen het, bereken. Generiese produkte het 58.7% (N = 292 071 van alle produkte wat voorgeskryf is, uitgemaak, teen ʼn totale koste van 28.2% (N= R1 346 210 929.00. Indien die gemiddelde prys van alle middels wat aan die kriteria vir vervanging voldoen het, met die prys vir generiese middels vervang word, is ʼn potensiële besparing van 9.3%(N = R56 183 697.91 van die werklike koste vir antidepressante gedurende die studietydperk moontlik. Generiese middels kan in ontwikkelende lande met beperkte gesondheidsorg-hulpbronne kostebesparende alternatiewe wees.

  11. Effect of processing on antioxidant potential and total phenolics content in beet (Beta vulgaris L.

    Directory of Open Access Journals (Sweden)

    Dorivaldo da Silva Raupp

    2011-09-01

    Full Text Available The antioxidant capacity of beet is associated with non-nutritive constituents, such as phenolic compounds. The purpose of this research was to evaluate the effect of two different heat-processing techniques (drying and canned on the antioxidant potential (ABTS and phenolics content of beets. A forced air circulation dehydrator was used for the drying. Drying at high temperatures (100 + 90 °C/5.6 hours; 90 °C/6 hours increased the antioxidant potential of the processed products while mild drying conditions decreased it (80 °C/6 hours; 100 + 70 °C/6 hours or had no effect on it (70 °C/7 hours; 100 + 80 °C/6 hours. For the canned products, the antioxidant potential did not differ according to the pH (4.2 to 3.8 for any of the four acids tested. Some processing methods influenced the antioxidant potential of the processed products, and this was also dependent on changes in the total phenolics content.

  12. Measurement of the total antioxidant potential in chronic obstructive pulmonary diseases with a novel automated method

    International Nuclear Information System (INIS)

    Ceylan, E.; Gencer, M.; Uzer, E.; Celik, H.

    2007-01-01

    To determine the oxidative and antioxidative status of plasma of patients with chronic obstructive pulmonary disease (COPD) and to compare these values with healthy smokers and healthy non-smokers control subjects using a more recently developed automated measurement method. This study involved 40 COPD patients, 25 healthy smokers, and 25 non-healthy smokers who attended the Chest Disease Outpatient Clinic in Harran University Research Hospital, Turkey between the period March 2006 and June 2006. We calculated the total antioxidant potential (TAOP) to determine the antioxidative status of plasma and we measured the total peroxide levels to determine the oxidative status of plasma. The TAOP of plasma was significantly lower in patients with COPD than in healthy smokers and healthy non-smokers (p< 0.001). In contrast, the mean total peroxide level of plasma was significantly higher in COPD patients than in healthy smokers and healthy non-smokers (p<0.001). We found a decreased in TAOP COPD patients using a simple, rapid and reliably automated colorimetric assay, which may suitable for use in routine clinical biochemistry laboratory and considerably facilitates the assessment of this useful clinical parameter. We suggest that this novel method may be used as a routine test to evaluate and follow-up the levels of oxidative stress in COPD. (author)

  13. Deliberate total parathyroidectomy: a potentially novel therapy for tumor-induced hypophosphatemic osteomalacia.

    Science.gov (United States)

    Bhadada, Sanjay K; Palnitkar, Saroj; Qiu, Shijing; Parikh, Nayana; Talpos, Gary B; Rao, Sudhaker D

    2013-11-01

    Tumor-induced osteomalacia (TIO) is an acquired hypophosphatemic metabolic bone disorder that can be cured by removing or ablating the offending tumor. However, when the tumor cannot be localized, lifelong therapy with oral phosphate and calcitriol or cinacalcet with close monitoring is required. A 56-year-old man was diagnosed with TIO in 1990. Initial therapy consisted of oral phosphate and calcitriol with symptomatic and biochemical improvement and healing of osteomalacia. Eight years later, hypercalcemic hyperparathyroidism developed, requiring subtotal parathyroidectomy with a transient increase in serum phosphate and normalization of serum calcium and PTH. Recurrent hypercalcemic hyperparathyroidism developed after 10 years of medical therapy. A deliberate total parathyroidectomy produced a prompt rise in serum phosphate into the normal range > 3.0 mg/dL and remained normal during the next 4 years of follow-up, despite continued very high serum fibroblast growth factor-23 levels throughout the 23-year follow-up. We report an unusual case of a TIO patient with long-term follow-up who developed recurrent hypercalcemic hyperparathyroidism on long-term oral phosphate therapy. Deliberate total parathyroidectomy normalized serum phosphate despite persistently elevated fibroblast growth factor-23 levels. Total parathyroidectomy offers a potentially novel therapy in some patients with TIO in whom medical therapy is not feasible or the tumor is unresectable.

  14. A technical analysis for cogeneration systems with potential applications in twelve California industrial plants. [energy saving heat-electricity utility systems

    Science.gov (United States)

    Moretti, V. C.; Davis, H. S.; Slonski, M. L.

    1978-01-01

    In a study sponsored by the State of California Energy Resources Conservation and Development Commission, 12 industrial plants in five utility districts were surveyed to assess the potential applications of the cogeneration of heat and electricity in California industry. Thermodynamic calculations were made for each plant in determining the energy required to meet the existing electrical and steam demands. The present systems were then compared to conceptual cogeneration systems specified for each plant. Overall energy savings were determined for the cogeneration applications. Steam and gas turbine topping cycle systems were considered as well as bottoming cycle systems. Types of industries studied were: pulp and paper, timber, cement, petroleum refining, enhanced oil recovery, foods processing, steel and glass

  15. Total system performance assessment - 1995: An evaluation of the potential Yucca Mountain Repository

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-11-01

    The U.S. Department of Energy (DOE) is currently investigating the feasibility of permanently disposing the nation`s commercial high-level radioactive wastes (in the form of spent fuel from the over 100 electric power-generating nuclear reactors across the U.S.) and a portion of the defense high-level radioactive wastes (currently stored at federal facilities around the country) in the unsaturated tuffaceous rocks at Yucca Mountain, Nevada. Quantitative predictions based on the most current understanding of the processes and parameters potentially affecting the long-term behavior of the disposal system are used to assess the ability of the site and its associated engineered designs to meet regulatory objectives set forward by the U.S. Nuclear Regulatory Commission (NRC) and the U.S. Environmental Protection Agency (EPA). The evaluation of the ability of the overall system to meet the performance objectives specified in the applicable regulatory standards has been termed total system performance assessment (TSPA). The aim of any total system performance assessment is to be as complete and reasonably conservative as possible and to assure that the descriptions of the predictive models and parameters are sufficient to ascertain their accuracy. Total system performance assessments evolve with time. As additional site and design information is generated, performance assessment analyses can be revised to become more representative of the expected conditions and remove some of the conservative assumptions necessitated by the incompleteness of site and design data. Previous iterations of total system performance assessment of the Yucca Mountain site and associated engineered barriers have been conducted in 1991 and 1993. These analyses have been documented in Barnard, Eslinger, Wilson and Andrews.

  16. Total system performance assessment - 1995: An evaluation of the potential Yucca Mountain Repository

    International Nuclear Information System (INIS)

    1995-11-01

    The U.S. Department of Energy (DOE) is currently investigating the feasibility of permanently disposing the nation's commercial high-level radioactive wastes (in the form of spent fuel from the over 100 electric power-generating nuclear reactors across the U.S.) and a portion of the defense high-level radioactive wastes (currently stored at federal facilities around the country) in the unsaturated tuffaceous rocks at Yucca Mountain, Nevada. Quantitative predictions based on the most current understanding of the processes and parameters potentially affecting the long-term behavior of the disposal system are used to assess the ability of the site and its associated engineered designs to meet regulatory objectives set forward by the U.S. Nuclear Regulatory Commission (NRC) and the U.S. Environmental Protection Agency (EPA). The evaluation of the ability of the overall system to meet the performance objectives specified in the applicable regulatory standards has been termed total system performance assessment (TSPA). The aim of any total system performance assessment is to be as complete and reasonably conservative as possible and to assure that the descriptions of the predictive models and parameters are sufficient to ascertain their accuracy. Total system performance assessments evolve with time. As additional site and design information is generated, performance assessment analyses can be revised to become more representative of the expected conditions and remove some of the conservative assumptions necessitated by the incompleteness of site and design data. Previous iterations of total system performance assessment of the Yucca Mountain site and associated engineered barriers have been conducted in 1991 and 1993. These analyses have been documented in Barnard, Eslinger, Wilson and Andrews

  17. Adding value while saving dollars: unleashing the potential of a national, integrated approach to home and community care.

    Science.gov (United States)

    Petch, Teresa; Shamian, Judith

    2009-01-01

    This commentary by Victorian Order of Nurses Canada, written in response to "Getting What We Pay For? The Value-for-Money Challenge," by McGrail, Zierler and Ip, answers four key questions about Canada's home and community care sector: (1) What are our objectives? (2) Where do we achieve good value now? (3) Where and why are we failing? and (4) What will help us do better? We conclude that although the home and community care sector offers great promise in meeting the evolving health and social needs of Canadians, it is not living up to its potential. We propose the development of a national, integrated approach to home and community care to help Canadians remain healthy and independent in their homes. This would represent a wise financial investment for governments and would contribute to the long-term health of Canadians.

  18. Option pricing: a flexible tool to disseminate shared savings contracts.

    Science.gov (United States)

    Friedberg, Mark W; Buendia, Anthony M; Lauderdale, Katherine E; Hussey, Peter S

    2013-08-01

    Due to volatility in healthcare costs, shared savings contracts can create systematic financial losses for payers, especially when contracting with smaller providers. To improve the business case for shared savings, we calculated the prices of financial options that payers can "sell" to providers to offset these losses. Using 2009 to 2010 member-level total cost of care data from a large commercial health plan, we calculated option prices by applying a bootstrap simulation procedure. We repeated these simulations for providers of sizes ranging from 500 to 60,000 patients and for shared savings contracts with and without key design features (minimum savings thresholds,bonus caps, cost outlier truncation, and downside risk) and under assumptions of zero, 1%, and 2% real cost reductions due to the shared savings contracts. Assuming no real cost reduction and a 50% shared savings rate, per patient option prices ranged from $225 (3.1% of overall costs) for 500-patient providers to $23 (0.3%) for 60,000-patient providers. Introducing minimum savings thresholds, bonus caps, cost outlier truncation, and downside risk reduced these option prices. Option prices were highly sensitive to the magnitude of real cost reductions. If shared savings contracts cause 2% reductions in total costs, option prices fall to zero for all but the smallest providers. Calculating the prices of financial options that protect payers and providers from downside risk can inject flexibility into shared savings contracts, extend such contracts to smaller providers, and clarify the tradeoffs between different contract designs, potentially speeding the dissemination of shared savings.

  19. Empirical assessment of the Hellenic non-residential building stock, energy consumption, emissions and potential energy savings

    International Nuclear Information System (INIS)

    Gaglia, Athina G.; Balaras, Constantinos A.; Mirasgedis, Sevastianos; Georgopoulou, Elena; Sarafidis, Yiannis; Lalas, Dimitris P.

    2007-01-01

    Comprehensive information and detailed data for the non-residential (NR) building stock is rather limited, although it is the fastest growing energy demand sector. This paper elaborates the approach used to determine the potential energy conservation in the Hellenic NR building stock. A major obstacle that had to be overcome was the need to make suitable assumptions for missing detailed primary data. A qualitative and quantitative assessment of scattered national data resulted in a realistic assessment of the existing NR building stock and energy consumption. Different energy conservation scenarios and their impact on the reduction of CO 2 emissions were evaluated. Accordingly, the most effective energy conservation measures are: addition of thermal insulation of exposed external walls, primarily in hotels and hospitals; installation of energy efficient lamps; installation of solar collectors for sanitary hot water production, primarily in hotels and health care; installation of building management systems in office/commercial and hotel buildings; replacement of old inefficient boilers; and regular maintenance of central heating boilers

  20. Elevated serum urate is a potential factor in reduction of total bilirubin: a Mendelian randomization study

    Science.gov (United States)

    Zhang, Hui; Liu, Jing; Dong, Zheng; Ding, Yue; Qian, Qiaoxia; Zhou, Jingru; Ma, Yanyun; Mei, Zhendong; Chen, Xiangxiang; Li, Yuan; Yuan, Ziyu; Zhang, Juan; Yang, Yajun; Chen, Xingdong; Jin, Li; Zou, Hejian; Wang, Xiaofeng; Wang, Jiucun

    2017-01-01

    Aim A Mendelian randomization study (MRS) can be linked to a “natural” randomized controlled trial in order to avoid potential bias of observational epidemiology. We aimed to study the possible association between serum urate (SU) and total bilirubin (TBIL) using MRS. Materials and Methods An observational epidemiological study using ordinary least squares (OLS) regression and MRS using two-stage least square (TLS) regression was conducted to assess the effect of SU on TBIL. The comparison between the OLS regression and the TLS regression was analyzed by the Durbin-Hausman test. If the p value is significant, it suggests that the OLS regression cannot evaluate the relationship between exposure and outcome, and the TLS regression is precise; while if the p value is not significant, there would be no significant difference between the two regressions. Results A total of 3,753 subjects were analyzed. In OLS regression, there was no significant association between SU and TBIL in all subjects and subgroup analysis (all p > 0.05). However, MRS revealed a negative correlation between SU and TBIL after adjustment for confounders (beta = –0.021, p = 0.010). Further analysis was conducted in different SU subgroups, and results show that elevated SU was associated with a significant reduction in TBIL after adjustment for hyperuricemic subjects (beta = –0.053, p = 0.027). In addition, the results using the Durbin-Hausman test further confirmed a negative effect of SU on TBIL (p = 0.002 and 0.010, respectively). Conclusions This research shows for the first time that elevated SU was a potential causal factor in the reduction of TBIL and it provides strong evidence to resolve the controversial association between SU and TBIL. PMID:29262606

  1. Total phenolic compounds, antioxidant potential and α-glucosidase inhibition by Tunisian Euphorbia paralias L.

    Directory of Open Access Journals (Sweden)

    Malek Besbes Hlila

    2016-08-01

    Full Text Available Objective: To examine the potential antioxidant and anti-α-glucosidase inhibitory activities of Tunisian Euphorbia paralias L. leaves and stems extracts and their composition of total polyphenol and flavonoids. Methods: The different samples were tested for their antiradical activities by using 2, 2’- azinobis(3-ethylbenzothiazoline-6-sulfonic acid (ABTS and 1,1-diphenyl-2-picrylhydrazyl (DPPH assays. In α-glucosidase activity, α-glucosidase (0.3 IU/mL and substrate, 2500 µmol/ L p-nitrophenyl α-D-glucopyranoside were used; absorbance was registered at 405 nm. Results: The leaves acetonic extract exhibited the strongest α-glucosidase inhibition [IC50 = (0.0035 ± 0.001 µg/mL], which was 20-fold more active than the standard product (acarbose [IC50 = (0.07 ± 0.01 µg/mL]. Acetonic extract of the leaves exhibited the highest quantity of total phenolic [(95.54 ± 0.04 µg gallic acid equivalent/mg] and flavonoid [(55.16 ± 0.25 µg quercetin equivalent/mg]. The obtained findings presented also that this extract was detected with best antioxidant capacity [IC50 = (0.015 ± 0.01 µg/mL] against DPPH and a value of IC50 equal to (0.02 ± 0.01 µg/mL against ABTS. Positive relationship between polyphenolic content of the tested Euphorbia paralias L. leaves and stems extracts and its antioxidant activity (DPPH and ABTS was detected. Elevated positive linear correlation was got between ABTS and total phenolic (R2 = 0.751. Conclusions: The findings clearly demonstrate that the use of a polar solvent enables extraction of significant quantities of phenol compounds and flavonoids.

  2. Potential cost saving of Epoetin alfa in elective hip or knee surgery due to reduction in blood transfusions and their side effects: a discrete-event simulation model.

    Directory of Open Access Journals (Sweden)

    Jörg Tomeczkowski

    Full Text Available OBJECTIVES: Transfusion of allogeneic blood is still common in orthopedic surgery. This analysis evaluates from the perspective of a German hospital the potential cost savings of Epoetin alfa (EPO compared to predonated autologous blood transfusions or to a nobloodconservationstrategy (allogeneic blood transfusion strategyduring elective hip and knee replacement surgery. METHODS: Individual patients (N = 50,000 were simulated based on data from controlled trials, the German DRG institute (InEK and various publications and entered into a stochastic model (Monte-Carlo of three treatment arms: EPO, preoperative autologous donation and nobloodconservationstrategy. All three strategies lead to a different risk for an allogeneic blood transfusion. The model focused on the costs and events of the three different procedures. The costs were obtained from clinical trial databases, the German DRG system, patient records and medical publications: transfusion (allogeneic red blood cells: €320/unit and autologous red blood cells: €250/unit, pneumonia treatment (€5,000, and length of stay (€300/day. Probabilistic sensitivity analyses were performed to determine which factors had an influence on the model's clinical and cost outcomes. RESULTS: At acquisition costs of €200/40,000 IU EPO is cost saving compared to autologous blood donation, and cost-effective compared to a nobloodconservationstrategy. The results were most sensitive to the cost of EPO, blood units and hospital days. CONCLUSIONS: EPO might become an attractive blood conservation strategy for anemic patients at reasonable costs due to the reduction in allogeneic blood transfusions, in the modeled incidence of transfusion-associated pneumonia andthe prolongedlength of stay.

  3. Potential cost saving of Epoetin alfa in elective hip or knee surgery due to reduction in blood transfusions and their side effects: a discrete-event simulation model.

    Science.gov (United States)

    Tomeczkowski, Jörg; Stern, Sean; Müller, Alfred; von Heymann, Christian

    2013-01-01

    Transfusion of allogeneic blood is still common in orthopedic surgery. This analysis evaluates from the perspective of a German hospital the potential cost savings of Epoetin alfa (EPO) compared to predonated autologous blood transfusions or to a nobloodconservationstrategy (allogeneic blood transfusion strategy)during elective hip and knee replacement surgery. Individual patients (N = 50,000) were simulated based on data from controlled trials, the German DRG institute (InEK) and various publications and entered into a stochastic model (Monte-Carlo) of three treatment arms: EPO, preoperative autologous donation and nobloodconservationstrategy. All three strategies lead to a different risk for an allogeneic blood transfusion. The model focused on the costs and events of the three different procedures. The costs were obtained from clinical trial databases, the German DRG system, patient records and medical publications: transfusion (allogeneic red blood cells: €320/unit and autologous red blood cells: €250/unit), pneumonia treatment (€5,000), and length of stay (€300/day). Probabilistic sensitivity analyses were performed to determine which factors had an influence on the model's clinical and cost outcomes. At acquisition costs of €200/40,000 IU EPO is cost saving compared to autologous blood donation, and cost-effective compared to a nobloodconservationstrategy. The results were most sensitive to the cost of EPO, blood units and hospital days. EPO might become an attractive blood conservation strategy for anemic patients at reasonable costs due to the reduction in allogeneic blood transfusions, in the modeled incidence of transfusion-associated pneumonia andthe prolongedlength of stay.

  4. Oil characterisation: assessment of composition, risks, degradation and remediation potential of total petroleum hydrocarbons in soil

    International Nuclear Information System (INIS)

    Lookman, R.; Vanermen, G.; Van De Weghe, H.; Gemoets, J.; Van der Sterren, G.; Alphenaar, A.

    2005-01-01

    Several methods are available for the characterization of petroleum hydrocarbons. The TPHCWG (Total Petroleum Hydrocarbon Criteria Working Group) developed a method based on a silica column separation of aromatics and aliphatics and a GC-FID subdivision into equivalent-carbon fractions (EC) ('TPH-method'). This method was mainly developed for assessing human risks of oil compounds. Within NOBIS (Dutch Research program Biological In-situ Remediation), another method was developed based upon an equilibrium-experiment of the oil-polluted soil with water (column recirculation), which was further developed by TTE ('TTE-method'). This method uses measured water solubilities of individual oil components and GC-retention times yielding a subdivision of the hydrocarbons into compound classes that are relevant for assessing the remediation potential of the specific oil pollution. In this paper we present results of a research project in which we developed a new method, the 'OK-method' that combines these two procedures and allows a complete characterisation of the oil in terms of composition, (human) risks, volatility, solubility, plume behaviour (migration velocities of the soluble components) and aerobic degradation potential. (authors)

  5. Oil characterisation: assessment of composition, risks, degradation and remediation potential of total petroleum hydrocarbons in soil

    Energy Technology Data Exchange (ETDEWEB)

    Lookman, R.; Vanermen, G.; Van De Weghe, H.; Gemoets, J. [Vito, Mol (Belgium); Van der Sterren, G.; Alphenaar, A. [TTE, Deventer (Netherlands)

    2005-07-01

    Several methods are available for the characterization of petroleum hydrocarbons. The TPHCWG (Total Petroleum Hydrocarbon Criteria Working Group) developed a method based on a silica column separation of aromatics and aliphatics and a GC-FID subdivision into equivalent-carbon fractions (EC) ('TPH-method'). This method was mainly developed for assessing human risks of oil compounds. Within NOBIS (Dutch Research program Biological In-situ Remediation), another method was developed based upon an equilibrium-experiment of the oil-polluted soil with water (column recirculation), which was further developed by TTE ('TTE-method'). This method uses measured water solubilities of individual oil components and GC-retention times yielding a subdivision of the hydrocarbons into compound classes that are relevant for assessing the remediation potential of the specific oil pollution. In this paper we present results of a research project in which we developed a new method, the 'OK-method' that combines these two procedures and allows a complete characterisation of the oil in terms of composition, (human) risks, volatility, solubility, plume behaviour (migration velocities of the soluble components) and aerobic degradation potential. (authors)

  6. Attenuated total reflectance-FT-IR spectroscopy for gunshot residue analysis: potential for ammunition determination.

    Science.gov (United States)

    Bueno, Justin; Sikirzhytski, Vitali; Lednev, Igor K

    2013-08-06

    The ability to link a suspect to a particular shooting incident is a principal task for many forensic investigators. Here, we attempt to achieve this goal by analysis of gunshot residue (GSR) through the use of attenuated total reflectance (ATR) Fourier transform infrared spectroscopy (FT-IR) combined with statistical analysis. The firearm discharge process is analogous to a complex chemical process. Therefore, the products of this process (GSR) will vary based upon numerous factors, including the specific combination of the firearm and ammunition which was discharged. Differentiation of FT-IR data, collected from GSR particles originating from three different firearm-ammunition combinations (0.38 in., 0.40 in., and 9 mm calibers), was achieved using projection to latent structures discriminant analysis (PLS-DA). The technique was cross (leave-one-out), both internally and externally, validated. External validation was achieved via assignment (caliber identification) of unknown FT-IR spectra from unknown GSR particles. The results demonstrate great potential for ATR-FT-IR spectroscopic analysis of GSR for forensic purposes.

  7. Fuel Savings and Aerodynamic Drag Reduction from Rail Car Covers

    Science.gov (United States)

    Storms, Bruce; Salari, Kambiz; Babb, Alex

    2008-01-01

    The potential for energy savings by reducing the aerodynamic drag of rail cars is significant. A previous study of aerodynamic drag of coal cars suggests that a 25% reduction in drag of empty cars would correspond to a 5% fuel savings for a round trip [1]. Rail statistics for the United States [2] report that approximately 5.7 billion liters of diesel fuel were consumed for coal transportation in 2002, so a 5% fuel savings would total 284 million liters. This corresponds to 2% of Class I railroad fuel consumption nationwide. As part of a DOE-sponsored study, the aerodynamic drag of scale rail cars was measured in a wind tunnel. The goal of the study was to measure the drag reduction of various rail-car cover designs. The cover designs tested yielded an average drag reduction of 43% relative to empty cars corresponding to an estimated round-trip fuel savings of 9%.

  8. Regional distribution of nitrogen fertilizer use and N-saving potential for improvement of food production and nitrogen use efficiency in China.

    Science.gov (United States)

    Wang, Xiaobin; Cai, Dianxiong; Hoogmoed, Willem B; Oenema, Oene

    2011-08-30

    An apparently large disparity still exists between developed and developing countries in historical trends of the amounts of nitrogen (N) fertilizers consumed, and the same situation holds true in China. The situation of either N overuse or underuse has become one of the major limiting factors in agricultural production and economic development in China. The issue of food security in N-poor regions has been given the greatest attention internationally. Balanced and appropriate use of N fertilizer for enriching soil fertility is an effective step in preventing soil degradation, ensuring food security, and further contributing to poverty alleviation and rural economic development in the N-poor regions. Based on the China Statistical Yearbook (2007), there could be scope for improvement of N use efficiency (NUE) in N-rich regions by reducing N fertilizer input to an optimal level (≤180 kg N ha(-1)), and also potential for increasing yield in the N-poor regions by further increasing N fertilizer supply (up to 116 kg N ha(-1)). For the N-rich regions, the average estimated potential of N saving and NUE increase could be about 15% and 23%, respectively, while for the N-poor regions the average estimated potential for yield increase could be 21% on a regional scale, when N input is increased by 13%. The study suggests that to achieve the goals of regional yield improvement, it is necessary to readjust and optimize regional distribution of N fertilizer use between the N-poor and N-rich regions in China, in combination with other nutrient management practices. Copyright © 2011 Society of Chemical Industry.

  9. Analysis of potential energy saving strategies in a Bangkok school building. With CD-ROM; Analyse von Energieeinsparpotentialen am Beispiel einer Schule in Bangkok

    Energy Technology Data Exchange (ETDEWEB)

    Temming, H.V.

    2000-05-01

    In cooperation with the Gesellschaft fuer technische Zusammenarbeit GTZ, a school building in Thailand was selected for an analysis of potentials for energy saving. The selected school was the New International School of Thailand (NIST) in Bangkok. Energy-relevant data were acquired by measurements, and solutions for more efficient energy supply were developed. Recommendations were made on this basis. This dissertation is also available on CD-ROM. [German] In Zusammenarbeit mit der Gesellschaft fuer technische Zusammenarbeit GTZ wurde als Beispielobjekt eine thailaendische Schule, die New International School of Thailand (NIST) in Bangkok ausgewaehlt. An diesem Objekt wurden die verschiedenen energetischen Messungen durchgefuehrt. Diese wurden bedarfsgerecht ausgewertet. Auf der Basis der Ergebnisse wurden Loesungsmoeglichkeiten fuer eine effizientere Energieversorgung der Schule konstruiert und diese Alternativen wie oben beschrieben bewertet, woraus sich entsprechende Empfehlungen ergeben. Der Aufbau dieser Arbeit stellt sich nun folgendermassen dar: Nachdem in einem ersten Schritt die fuer diesen Kontext wichtigsten Parameter Thailands und des Untersuchungsobjektes dargestellt werden, schliesst sich hieran die Vorstellung verschiedener technische Alternativen zur Erzeugung von Kaelte an, da hier ein Fokus fuer moegliche Energieeinsparungen gesetzt wird. Anschliessend werden einige in der Arbeit verwandte Berechnungsverfahren fuer energetische oder wirtschaftliche Zuammenhaenge sowie eine ausfuehrliche Beschreibung der energetischen 1st-Situation des Untersuchungsobjektes dargestellt. Darauf aufbauend folgt nun die Vorstellung der verschiedenen Energieeinsparpotentiale durch technische und verhaltensinduzierte Optimierungsmassnahmen. Diese Arbeit endet mit der Bewertung aller aufgedeckten Potentiale und einem Gesamtfazit aus der Untersuchung. (Diese Diplomarbeit liegt auch in Form einer CD-ROM vor.) (orig./AKF)

  10. Effects of heat and electricity saving measures in district-heated multistory residential buildings

    International Nuclear Information System (INIS)

    Truong, Nguyen Le; Dodoo, Ambrose; Gustavsson, Leif

    2014-01-01

    Highlights: • We analyzed the potential for energy savings in district heated buildings. • Measures that reduce more peak load production give higher primary energy savings. • Efficient appliances increase heat demand but give net primary energy savings. • Efficient appliances give the largest net primary energy savings. - Abstract: The effects of heat and electricity saving measures in district-heated buildings can be complex because these depend not only on how energy is used on the demand side but also on how energy is provided from the supply side. In this study, we analyze the effects of heat and electricity saving measures in multistory concrete-framed and wood-framed versions of an existing district-heated building and examine the impacts of the reduced energy demand on different district heat (DH) production configurations. The energy saving measures considered are for domestic hot water reduction, building thermal envelope improvement, ventilation heat recovery (VHR), and household electricity savings. Our analysis is based on a measured heat load profile of an existing DH production system in Växjö, Sweden. Based on the measured heat load profile, we model three minimum-cost DH production system using plausible environmental and socio-political scenarios. Then, we investigate the primary energy implications of the energy saving measures applied to the two versions of the existing building, taking into account the changed DH demand, changed cogenerated electricity, and changed electricity use due to heat and electricity saving measures. Our results show that the difference between the final and primary energy savings of the concrete-framed and wood-framed versions of the case-study building is minor. The primary energy efficiency of the energy saving measures depends on the type of measure and on the composition of the DH production system. Of the various energy saving measures explored, electricity savings give the highest primary energy savings

  11. Successful building and sanitation - Energy-saving potentials in house and apartments - Bad Homburg vor der Hoehe. 2. ed.; Erfolgreich sanieren - Energiesparpotentiale in Haus und Wohnung - Bad Homburg vor der Hoehe

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2010-07-01

    Climate protection and high energy costs require a reduction of the energy consumption in new buildings and in existing buildings. In 1995, the city Bad Homburg v.d. Hoehe (Federal Republic of Germany) let draw up an energy concept in order to uncover the potentials to effective climate protection. The brochure under consideration is addressed to house owners which would like to reorganize their buildings professionally and energy-saving and to receive a ''first aid'' with this brochure. This brochure consists of the following contributions: (a) Energy-saving construction and reorganization - an investment into the future; (b) Measures of reorganization and saving potentials; (c) Renewable energies in the house; (d) Electricity: The energy in the background; (e) Financial incentives in the overview. (orig./GL)

  12. Electric energy savings from new technologies. Revision 1

    Energy Technology Data Exchange (ETDEWEB)

    Harrer, B.J.; Kellogg, M.A.; Lyke, A.J.; Imhoff, K.L.; Fisher, Z.J.

    1986-09-01

    Purpose of the report is to provide information about the electricity-saving potential of new technologies to OCEP that it can use in developing alternative long-term projections of US electricity consumption. Low-, base-, and high-case scenarios of the electricity savings for 10 technologies were prepared. The total projected annual savings for the year 2000 for all 10 technologies were 137 billion kilowatt hours (BkWh), 279 BkWh, and 470 BkWh, respectively, for the three cases. The magnitude of these savings projections can be gauged by comparing them to the Department's reference case projection for the 1985 National Energy Policy Plan. In the Department's reference case, total consumption in 2000 is projected to be 3319 BkWh. Because approximately 75% of the base-case estimate of savings are already incorporated into the reference projection, only 25% of the savings estimated here should be subtracted from the reference projection for analysis purposes.

  13. REMINDER: Saved Leave Scheme (SLS)

    CERN Multimedia

    2003-01-01

    Transfer of leave to saved leave accounts Under the provisions of the voluntary saved leave scheme (SLS), a maximum total of 10 days'* annual and compensatory leave (excluding saved leave accumulated in accordance with the provisions of Administrative Circular No 22B) can be transferred to the saved leave account at the end of the leave year (30 September). We remind you that unused leave of all those taking part in the saved leave scheme at the closure of the leave year accounts is transferred automatically to the saved leave account on that date. Therefore, staff members have no administrative steps to take. In addition, the transfer, which eliminates the risk of omitting to request leave transfers and rules out calculation errors in transfer requests, will be clearly shown in the list of leave transactions that can be consulted in EDH from October 2003 onwards. Furthermore, this automatic leave transfer optimizes staff members' chances of benefiting from a saved leave bonus provided that they ar...

  14. Specific and total N-nitrosamines formation potentials of nitrogenous micropollutants during chloramination.

    Science.gov (United States)

    Piazzoli, Andrea; Breider, Florian; Aquillon, Caroline Gachet; Antonelli, Manuela; von Gunten, Urs

    2018-05-15

    N-nitrosamines are a group of potent human carcinogens that can be formed during oxidative treatment of drinking water and wastewater. Many tertiary and quaternary amines present in consumer products (e.g., pharmaceuticals, personal care and household products) are known to be N-nitrosodimethylamine (NDMA) precursors during chloramination, but the formation of other N-nitrosamines has been rarely studied. This study investigates the specific and total N-nitrosamine (TONO) formation potential (FP) of various precursors from nitrogen-containing micropollutants (chlorhexidine, metformin, benzalkonium chloride and cetyltrimethylammonium chloride) and tertiary and quaternary model amines (trimethyl amine, N,N-dimethylbutyl amine, N,N-dimethylbenzyl amine and tetramethyl ammonium). All the studied nitrogenous micropollutants displayed quantifiable TONO FP, with molar yields in the range 0.04-11.92%. However, the observed TONO pools constituted mostly of uncharacterized species, not included in US-EPA 8270 N-nitrosamines standard mix. Only the quaternary ammonium compound benzalkonium chloride showed quantifiable NDMA FP (0.56% molar yield), however, explaining only a minor fraction of the observed TONO FP. The studied model amines showed molar NDMA yields from 0.10% (trimethyl amine) to 5.05% (N,N-dimethylbenzyl amine), very similar to the molar TONO yields. The comparison of the FPs of micropollutants and model compounds showed that the presence of electron donating functional groups (such as a benzyl group) in tertiary and quaternary amine precursors leads to a higher formation of NDMA and uncharacterized N-nitrosamines, respectively. LC-qTOF screening of a list of proposed N-nitrosamine structures has enabled to identify a novel N-nitrosamine (N-nitroso-N-methyldodecylamine) from the chloramination of benzalkonium chloride. This finding supports the hypothesis that different functional groups in quaternary amines can act as leaving groups during chloramination and

  15. Improved estimates of filtered total mercury loadings and total mercury concentrations of solids from potential sources to Sinclair Inlet, Kitsap County, Washington

    Science.gov (United States)

    Paulson, Anthony J.; Conn, Kathleen E.; DeWild, John F.

    2013-01-01

    Previous investigations examined sources and sinks of mercury to Sinclair Inlet based on historic and new data. This included an evaluation of mercury concentrations from various sources and mercury loadings from industrial discharges and groundwater flowing from the Bremerton naval complex to Sinclair Inlet. This report provides new data from four potential sources of mercury to Sinclair Inlet: (1) filtered and particulate total mercury concentrations of creek water during the wet season, (2) filtered and particulate total mercury releases from the Navy steam plant following changes in the water softening process and discharge operations, (3) release of mercury from soils to groundwater in two landfill areas at the Bremerton naval complex, and (4) total mercury concentrations of solids in dry dock sumps that were not affected by bias from sequential sampling. The previous estimate of the loading of filtered total mercury from Sinclair Inlet creeks was based solely on dry season samples. Concentrations of filtered total mercury in creek samples collected during wet weather were significantly higher than dry weather concentrations, which increased the estimated loading of filtered total mercury from creek basins from 27.1 to 78.1 grams per year. Changes in the concentrations and loading of filtered and particulate total mercury in the effluent of the steam plant were investigated after the water softening process was changed from ion-exchange to reverse osmosis and the discharge of stack blow-down wash began to be diverted to the municipal water-treatment plant. These changes reduced the concentrations of filtered and particulate total mercury from the steam plant of the Bremerton naval complex, which resulted in reduced loadings of filtered total mercury from 5.9 to 0.15 grams per year. Previous investigations identified three fill areas on the Bremerton naval complex, of which the western fill area is thought to be the largest source of mercury on the base

  16. Supporting the Future Total Force: A Methodology for Evaluating Potential Air National Guard Mission Assignments

    National Research Council Canada - National Science Library

    Lynch, Kristin F; Drew, John G; Sleeper, Sally; Williams, William A; Masters, James M; Luangkesorn, Louis; Tripp, Robert S; Lichter, Dahlia S; Roll, Charles R

    2007-01-01

    ... trained, highly experienced personnel with no aircraft to operate and support. The authors develop a methodology to evaluate missions that could be transferred from the active component to the ANG without significant cost to the total force...

  17. Metrics for Identifying Food Security Status and the Population with Potential to Benefit from Nutrition Interventions in the Lives Saved Tool (LiST).

    Science.gov (United States)

    Jackson, Bianca D; Walker, Neff; Heidkamp, Rebecca

    2017-11-01

    Background: The Lives Saved Tool (LiST) uses the poverty head-count ratio at $1.90/d as a proxy for food security to identify the percentage of the population with the potential to benefit from balanced energy supplementation and complementary feeding (CF) interventions, following the approach used for the Lancet 's 2008 series on Maternal and Child Undernutrition. Because much work has been done in the development of food security indicators, a re-evaluation of the use of this indicator was warranted. Objective: The aim was to re-evaluate the use of the poverty head-count ratio at $1.90/d as the food security proxy indicator in LiST. Methods: We carried out a desk review to identify available indicators of food security. We identified 3 indicators and compared them by using scatterplots, Spearman's correlations, and Bland-Altman plot analysis. We generated LiST projections to compare the modeled impact results with the use of the different indicators. Results: There are many food security indicators available, but only 3 additional indicators were identified with the data availability requirements to be used as the food security indicator in LiST. As expected, analyzed food security indicators were significantly positively correlated ( P security indicators that were used in the meta-analyses that produced the effect estimates. These are the poverty head-count ratio at $1.90/d for CF interventions and the prevalence of a low body mass index in women of reproductive age for balanced energy supplementation interventions. © 2017 American Society for Nutrition.

  18. Energy savings: persuasion and persistence

    Energy Technology Data Exchange (ETDEWEB)

    Eijadi, David; McDougall, Tom; Leaf, Kris; Douglas, Jim; Steinbock, Jason; Reimer, Paul [The Weidt Group, Minnetonka, MN (United States); Gauthier, Julia [Xcel Energy, Minneapolis, MN (United States); Wild, Doug; Richards McDaniel, Stephanie [BWBR Architects, Inc., Saint Paul, MN (United States)

    2005-07-01

    In this study, the architects, sponsoring utility and energy simulation specialist joined together to investigate the persistence of energy savings in three completed projects: a college library; a municipal transportation facility; and a hospital. The primary question being 'How well did the design decisions made with the help of simulation analysis translate into building operations over several years?' Design simulation and metered performance data are compared for specific energy-saving strategies. The paper provides a brief overview of the basis of selection of the three projects, the energy design assistance methods employed and the decisions made, along with their savings expectations. For each case, design characteristics, modelling assumptions, selected strategies and actual metered performance are outlined. We find evidence of appropriate levels of energy conservation, but they are not the absolute values predicted. In each case, the discrepancies between modelling assumptions and final construction or operating procedures are identified, examined and rectified. The paper illustrates that while owners are saving energy, they are not always getting the full savings potential for what they install. The paper concludes with a re-examination of the overall process. It evaluates the potential for additional savings of individual technologies and related larger utility incentives to design teams and building owners.

  19. Does energy labelling on residential housing cause energy savings?

    Energy Technology Data Exchange (ETDEWEB)

    Kjaerbye, V.H.

    2009-07-01

    Danish households use more than 30% of the total amount of energy being used in Denmark. More than 80% of this energy is dedicated to space heating. The same relation is seen in many OECD countries. The corresponding energy savings potential was recently estimated at 30% of the energy used in buildings. Energy labelling is seen as an important instrument to target these potential energy savings. This paper evaluates the effects of the Danish Energy Labelling Scheme on energy consumption in existing single-family houses with propensity score matching using real metered natural gas consumption and a very wide range of register data describing the houses and households. The study did not find significant energy savings due to the Danish Energy Labelling Scheme, but more research would be needed to complement this conclusion

  20. Anti-tumor potential of total alkaloid extract of Prosopis juliflora DC ...

    African Journals Online (AJOL)

    Jane

    2011-08-15

    Aug 15, 2011 ... Cancer is the second leading cause of death in the world. (Madhusudan and .... formula and from that the percentage of cytotoxicity and IC50 values ... complete media were treated as positive and negative controls, .... Cytotoxic effect of total alkaloid extract of P. juliflora leaves against cancer (black bars).

  1. Estimate of Cost-Effective Potential for Minimum Efficiency Performance Standards in 13 Major World Economies Energy Savings, Environmental and Financial Impacts

    Energy Technology Data Exchange (ETDEWEB)

    Letschert, Virginie E. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Bojda, Nicholas [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Ke, Jing [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); McNeil, Michael A. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2012-07-01

    This study analyzes the financial impacts on consumers of minimum efficiency performance standards (MEPS) for appliances that could be implemented in 13 major economies around the world. We use the Bottom-Up Energy Analysis System (BUENAS), developed at Lawrence Berkeley National Laboratory (LBNL), to analyze various appliance efficiency target levels to estimate the net present value (NPV) of policies designed to provide maximum energy savings while not penalizing consumers financially. These policies constitute what we call the “cost-effective potential” (CEP) scenario. The CEP scenario is designed to answer the question: How high can we raise the efficiency bar in mandatory programs while still saving consumers money?

  2. Risk transfer via energy-savings insurance

    International Nuclear Information System (INIS)

    Mills, Evan

    2003-01-01

    Among the key barriers to investment in energy efficiency are uncertainties about attaining projected energy savings and potential disputes over stipulated savings. The fields of energy management and risk management are thus intertwined. While many technical methods have emerged to manage performance risks (e.g. building diagnostics and commissioning), financial methods are less developed in the energy management arena than in other segments of the economy. Energy-savings insurance (ESI) - formal insurance of predicted energy savings - transfers and spreads both types of risk over a larger pool of energy efficiency projects and reduces barriers to market entry of smaller energy service firms who lack sufficiently strong balance sheets to self-insure the savings. ESI encourages those implementing energy-saving projects to go beyond standard measures and thereby achieve more significant levels of energy savings. Insurance providers are proponents of improved savings measurement and verification techniques, as well as maintenance, thereby contributing to national energy-saving objectives. If properly applied, ESI can potentially reduce the net cost of energy-saving projects by reducing the interest rates charged by lenders, and by increasing the level of savings through quality control. Governmental agencies have been pioneers in the use of ESI and could continue to play a role

  3. The potential influence of regionalization strategies on delivery of care for elective total joint arthroplasty.

    Science.gov (United States)

    Dy, Christopher J; Marx, Robert G; Ghomrawi, Hassan M K; Pan, Ting Jung; Westrich, Geoffrey H; Lyman, Stephen

    2015-01-01

    Regionalization of total joint arthroplasty (TJA) to high volume hospitals (HVHs) may affect access to care and complication risk. Using administrative data, 2,560,314 patients who underwent primary total hip or knee arthroplasty from 1991 to 2006 were categorized by whether an HVH (>200 annual TJAs) was available locally. Associations among patient characteristics, hospital utilization, and in-hospital complications were estimated using regression modeling. The complication risk was higher (Odds Ratio 1.18 [95% CI: 1.16, 1.20]) if patients went to a local low volume hospital. Black and Medicaid patients were more likely to utilize the local low volume hospital than a local HVH. Utilizing a local HVH is associated with lower complication risks. However, patients from vulnerable groups were less likely to utilize these patterns. Copyright © 2014 Elsevier Inc. All rights reserved.

  4. Learning to save lives!

    CERN Document Server

    2003-01-01

    They're all around you and watch over you, but you won't be aware of them unless you look closely at their office doors. There are 308 of them and they have all been given 12 hours of training with the CERN Fire Brigade. Who are they? Quite simply, those who could one day save your life at work, the CERN first-aiders. First-aiders are recruited on a volunteer basis. "Training is in groups of 10 to 12 people and a lot of emphasis is placed on the practical to ensure that they remember the life-saving techniques we show them", explains Patrick Berlinghi, a CERN first-aid instructor from TIS Division. He is looking forward to the arrival of four new instructors, which will bring the total number to twelve (eleven firemen and one member of the Medical Service). "The new instructors were trained at CERN from 16 to 24 May by Marie-Christine Boucher Da Ros (a member of the Commission Pédagogie de l'Observatoire National Français du Secourisme, the education commission of France's national first-aid body). This in...

  5. Total Content of Carotenoids in Corn Landraces and Their Potential Health Applications

    Directory of Open Access Journals (Sweden)

    Stăncuța Scrob

    2014-11-01

    Full Text Available The research was designed to quantify the carotenoid compounds from the experimental variability of the corn genotypes. The experimental material for the present investigation consisted of 19 corn hybrids from Agricultural Research and Development Station (ARDSTurda, Romania. The experiment was carried out during two seasons 2011 and 2012. Corn hybrids Turda 215, Mold Turda 188, Turda 200, Turda SU 181 and HS 105 were noticed by the fact that in the year of culture 2012, they showed a beginning of accumulation of total content of carotenoids more than 27 µg/g DW as compared to 15 µg/g DW corresponding to the year o culture 2011 due to soil and climate conditions favoring the accumulation of carotenoid compounds. According to our study, the highest concentration of TC was recorded in light yellow, dark yellow and orange hybrids.

  6. The total pregnancy potential per oocyte aspiration after assisted reproduction-in how many cycles are biologically competent oocytes available?

    DEFF Research Database (Denmark)

    Lemmen, J G; Rodríguez, N M; Andreasen, L D

    2016-01-01

    PURPOSE: While stimulation of women prior to assisted reproduction is associated with increased success rates, the total biological pregnancy potential per stimulation cycle is rarely assessed. METHODS: Retrospective sequential cohort study of the cumulative live birth rate in 1148 first IVF/ICSI...

  7. Water saving at the field scale with Irrig-OH, an open-hardware environment device for soil water potential monitoring and irrigation management

    Science.gov (United States)

    Masseroni, Daniele; Facchi, Arianna; Gandolfi, Claudio

    2015-04-01

    Sustainability of irrigation practices is an important objective which should be pursued in many countries, especially in areas where water scarcity causes strong conflicts among the different water uses. The efficient use of water is a key factor in coping with the food demand of an increasing world population and with the negative effects of the climate change on water resources availability in many areas. In this complex context, it is important that farmers adopt instruments and practices that enable a better management of water at the field scale, whatever the irrigation method they adopt. This work presents the hardware structure and the functioning of an open-hardware microstation based on the Arduino technology, called Irrig-OH, which allows the continuous and low-cost monitoring of the soil water potential (SWP) in the root zone for supporting the irrigation scheduling at the field scale. In order to test the microstation, an experiment was carried out during the agricultural season 2014 at Lodi (Italy), with the purpose of comparing the farmers' traditional management of irrigation of a peach variety and the scheduling based on the SWP measurements provided by the microstation. Additional measurements of leaf water potential (LWP), stomatal resistance, transpiration (T), crop water stress index (CWSI) and fruit size evolution were performed respectively on leafs and fruits for verifying the plant physiological responses on different SWP levels in soil. At the harvesting time, the peach production in term of quantity and quality (sucrose content was measured by a rifractometer over a sample of one hundred fruits) of the two rows were compared. Irrigation criteria was changed with respect to three macro-periods: up to the endocarp hardening phase (begin of May) soil was kept well watered fixing the SWP threshold in the first 35 cm of the soil profile at -20 kPa, during the pit hardening period (about the entire month of May) the allowed SWP threshold was

  8. Total scattering cross sections and interatomic potentials for neutral hydrogen and helium on some noble gases

    International Nuclear Information System (INIS)

    Ruzic, D.N.; Cohen, S.A.

    1985-04-01

    Measurements of energy-dependent scattering cross sections for 30 to 1800 eV D incident on He, Ne, Ar, and Kr, and for 40 to 850 eV He incident on He, Ar, and Kr are presented. They are determined by using the charge-exchange efflux from the Princeton Large Torus tokamak as a source of D or He. These neutrals are passed through a gas-filled scattering cell and detected by a time-of-flight spectrometer. The cross section for scattering greater than the effective angle of the apparatus (approx. =20 mrad) is found by measuring the energy-dependent attenuation of D or He as a function of pressure in the scattering cell. The interatomic potential is extracted from the data

  9. Total bilirubin in nasogastric aspirates: A potential new indicator of postoperative gastrointestinal recovery

    Directory of Open Access Journals (Sweden)

    Go Miyano

    2013-01-01

    Full Text Available Background: The aim of our study was to investigate if total bilirubin (T-bil, amylase (Amy, and sodium (Na in nasogastric (NG aspirates can reflect gastrointestinal motility reliably. Materials and Methods: NG aspirates from all laparotomies lasting more than 150 min in children less than 12 months old were studied for 3 months. Color of aspirates and intensity of bowel sounds were graded every 3 h by nursing staff and aspirate samples for measuring T-bil, Amy, and Na were collected independently every 12 h until an oral fluid challenge was tolerated. Results: There were 26 subjects. Mean age at surgery was 5.6 months; mean body weight at surgery was 5.8 kg. No postoperative complications occurred. While there was no reduction in average volume of NG aspirates, color change was subjective, and bowel sounds could not be standardized, T-bil decreased over time (0d: 4.4 mg/dL; 0.5d: 2.7 mg/dL; 1.0d: 1.6 mg/dL; 1.5d: 1.3 mg/dL; 2.0d: 0.4 mg/dL; 2.5d: 0.33 mg/dL; 3.0d: 0.21 mg/dL; 3.5d: 0.15 mg/dL; 4.0d: 0.06 mg/dL; 4.5d: 0.05 mg/dL; 5.0d: 0.02 mg/dL; 5.5d: 0.02 mg/dL; 6.0d: 0.01 mg/dL. Amy and Na were inconclusive. Conclusion: T-bil levels in NG aspirates may be useful as a reliable objective quantitative marker of gastrointestinal motility postoperatively.

  10. Social Capital and Savings Behaviour

    DEFF Research Database (Denmark)

    Newman, Carol; Tarp, Finn; Van Den Broeck, Katleen

    We explore the extent to which social capital can play a role in imparting information about the returns to saving where potential knowledge gaps and mistrust exists. Using data from Vietnam we find strong evidence to support the hypothesis that information transmitted via reputable social...

  11. Private Sector Savings

    Directory of Open Access Journals (Sweden)

    Pitonáková Renáta

    2018-03-01

    Full Text Available The majority of household savings are in the form of bank deposits. It is therefore of interest for credit institutions to tailor their deposit policy for getting finances from non-banking entities and to provide the private sector with the loans that are necessary for investment activities and consumption. This paper deals with the determinants of the saving rate of the private sector of Slovakia. Economic, financial and demographic variables influence savings. Growth of income per capita, private disposable income, elderly dependency ratio, real interest rate and inflation have a positive impact on savings, while increases in public savings indicate a crowding out effect. The inflation rate implies precautionary savings, and dependency ratio savings for bequest. There are also implications for governing institutions deciding on the implementation of appropriate fiscal and monetary operations.

  12. Potential Cardiovascular and Total Mortality Benefits of Air Pollution Control in Urban China.

    Science.gov (United States)

    Huang, Chen; Moran, Andrew E; Coxson, Pamela G; Yang, Xueli; Liu, Fangchao; Cao, Jie; Chen, Kai; Wang, Miao; He, Jiang; Goldman, Lee; Zhao, Dong; Kinney, Patrick L; Gu, Dongfeng

    2017-10-24

    Outdoor air pollution ranks fourth among preventable causes of China's burden of disease. We hypothesized that the magnitude of health gains from air quality improvement in urban China could compare with achieving recommended blood pressure or smoking control goals. The Cardiovascular Disease Policy Model-China projected coronary heart disease, stroke, and all-cause deaths in urban Chinese adults 35 to 84 years of age from 2017 to 2030 if recent air quality (particulate matter with aerodynamic diameter ≤2.5 µm, PM 2.5 ) and traditional cardiovascular risk factor trends continue. We projected life-years gained if urban China were to reach 1 of 3 air quality goals: Beijing Olympic Games level (mean PM 2.5 , 55 μg/m 3 ), China Class II standard (35 μg/m 3 ), or World Health Organization standard (10 μg/m 3 ). We compared projected air pollution reduction control benefits with potential benefits of reaching World Health Organization hypertension and tobacco control goals. Mean PM 2.5 reduction to Beijing Olympic levels by 2030 would gain ≈241,000 (95% uncertainty interval, 189 000-293 000) life-years annually. Achieving either the China Class II or World Health Organization PM 2.5 standard would yield greater health benefits (992 000 [95% uncertainty interval, 790 000-1 180 000] or 1 827 000 [95% uncertainty interval, 1 481 00-2 129 000] annual life-years gained, respectively) than World Health Organization-recommended goals of 25% improvement in systolic hypertension control and 30% reduction in smoking combined (928 000 [95% uncertainty interval, 830 000-1 033 000] life-years). Air quality improvement in different scenarios could lead to graded health benefits ranging from 241 000 life-years gained to much greater benefits equal to or greater than the combined benefits of 25% improvement in systolic hypertension control and 30% smoking reduction. © 2017 American Heart Association, Inc.

  13. What are the cost savings associated with providing access to specialist care through the Champlain BASE eConsult service? A costing evaluation

    Science.gov (United States)

    Liddy, Clare; Drosinis, Paul; Deri Armstrong, Catherine; McKellips, Fanny; Afkham, Amir; Keely, Erin

    2016-01-01

    Objective This study estimates the costs and potential savings associated with all eConsult cases completed between 1 April 2014 and 31 March 2015. Design Costing evaluation from the societal perspective estimating the costs and potential savings associated with all eConsults completed during the study period. Setting Champlain health region in Eastern Ontario, Canada. Population Primary care providers and specialists registered to use the eConsult service. Main outcome measures Costs included (1) delivery costs; (2) specialist remuneration; (3) costs associated with traditional (face-to-face) referrals initiated as a result of eConsult. Potential savings included (1) costs of traditional referrals avoided; (2) indirect patient savings through avoided travel and lost wages/productivity. Net potential societal cost savings were estimated by subtracting total costs from total potential savings. Results A total of 3487 eConsults were completed during the study period. In 40% of eConsults, a face-to-face specialist visit was originally contemplated but avoided as result of eConsult. In 3% of eConsults, a face-to-face specialist visit was not originally contemplated but was prompted as a result of the eConsult. From the societal perspective, total costs were estimated at $207 787 and total potential savings were $246 516. eConsult led to a net societal saving of $38 729 or $11 per eConsult. Conclusions Our findings demonstrate potential cost savings from the societal perspective, as patients avoided the travel costs and lost wages/productivity associated with face-to-face specialist visits. Greater savings are expected once we account for other costs such as avoided tests and visits and potential improved health outcomes associated with shorter wait times. Our findings are valuable for healthcare delivery decision-makers as they seek solutions to improve care in a patient-centred and efficient manner. PMID:27338880

  14. Potential impact of single-risk-factor versus total risk management for the prevention of cardiovascular events in Seychelles.

    Science.gov (United States)

    Ndindjock, Roger; Gedeon, Jude; Mendis, Shanthi; Paccaud, Fred; Bovet, Pascal

    2011-04-01

    To assess the prevalence of cardiovascular (CV) risk factors in Seychelles, a middle-income African country, and compare the cost-effectiveness of single-risk-factor management (treating individuals with arterial blood pressure ≥ 140/90 mmHg and/or total serum cholesterol ≥ 6.2 mmol/l) with that of management based on total CV risk (treating individuals with a total CV risk ≥ 10% or ≥ 20%). CV risk factor prevalence and a CV risk prediction chart for Africa were used to estimate the 10-year risk of suffering a fatal or non-fatal CV event among individuals aged 40-64 years. These figures were used to compare single-risk-factor management with total risk management in terms of the number of people requiring treatment to avert one CV event and the number of events potentially averted over 10 years. Treatment for patients with high total CV risk (≥ 20%) was assumed to consist of a fixed-dose combination of several drugs (polypill). Cost analyses were limited to medication. A total CV risk of ≥ 10% and ≥ 20% was found among 10.8% and 5.1% of individuals, respectively. With single-risk-factor management, 60% of adults would need to be treated and 157 cardiovascular events per 100000 population would be averted per year, as opposed to 5% of adults and 92 events with total CV risk management. Management based on high total CV risk optimizes the balance between the number requiring treatment and the number of CV events averted. Total CV risk management is much more cost-effective than single-risk-factor management. These findings are relevant for all countries, but especially for those economically and demographically similar to Seychelles.

  15. Potential for energy saving and renewable energy in Utrecht, Netherlands. Preliminary validation for the Utrecht municipality; Potentieel energiebesparing en duurzame energie Utrecht. Onderbouwingsnotitie voor de gemeente Utrecht

    Energy Technology Data Exchange (ETDEWEB)

    Benner, J.H.B.; Warringa, G.E.A.

    2012-10-15

    Utrecht has stated its intention to achieve CO2 neutrality of the local energy supply by 2030. Having conducted its own exploratory study into the steps that would need to be taken to achieve this aim, City Hall asked CE Delft to pass judgment on the target and how it is hoped to be achieved. While characterized by both CE Delft and interviewed scientists as very substantial, Utrecht's ambitions are also regarded as a worthy aim to pursue. City Hall's estimates of the reduction potential of the envisaged measures 28% of total projected emission cuts in 2030 via energy efficiency measures and 35% via renewable energy - are deemed realistic by CE Delft. Although the potential reduction via all options was estimated on the basis of the maximum feasible potential, there still remains a substantial policy gap. The analysis makes clear that robust policy choices are required in order to come close to achieving the stated ambitions [Dutch] De gemeente Utrecht heeft zich tot doel gesteld om in 2030 de lokale energievoorziening CO2-neutraal te hebben. Binnen de gemeente is een ambtelijke verkenning uitgevoerd naar de maatregelen om invulling te geven aan deze ambitie. Utrecht heeft CE Delft gevraagd een oordeel te geven over de ambitie en de invulling daarvan. De ambitie van Utrecht wordt zowel door CE Delft als geïnterviewde wetenschappers getypeerd als fors, maar tegelijk als een goed punt aan de horizon om naar toe te werken. De inschattingen van Utrecht rond het reductiepotentieel van de maatregelen worden door CE Delft beoordeeld als realistisch. Dit houdt in dat 28% van de totaal verwachte uitstoot in 2030 wordt gereduceerd door besparingsmaatregelen en 35% met de inzet van duurzame energie. Hoewel bij de inschatting van de mogelijke reductie voor alle opties is gerekend met het maximaal haalbare potentieel resteert er een aanzienlijk beleidsgat. De analyse maakt duidelijk dat echte beleidskeuzen nodig zijn om realisatie van de ambitie te benaderen.

  16. Potential benefits of cool roofs on commercial buildings. Conserving energy, saving money, and reducing emission of greenhouse gases and air pollutants

    International Nuclear Information System (INIS)

    Levinson, R.; Akbari, H.

    2010-01-01

    Cool roofs - roofs that stay cool in the sun by minimizing solar absorption and maximizing thermal emission - lessen the flow of heat from the roof into the building, reducing the need for space cooling energy in conditioned buildings. Cool roofs may also increase the need for heating energy in cold climates. For a commercial building, the decrease in annual cooling load is typically much greater than the increase in annual heating load. This study combines building energy simulations, local energy prices, local electricity emission factors, and local estimates of building density to characterize local, state average, and national average cooling energy savings, heating energy penalties, energy cost savings, and emission reductions per unit conditioned roof area. The annual heating and cooling energy uses of four commercial building prototypes - new office (1980+), old office (pre-1980), new retail (1980+), and old retail (pre-1980) - were simulated in 236 US cities. Substituting a weathered cool white roof (solar reflectance 0.55) for a weathered conventional gray roof (solar reflectance 0.20) yielded annually a cooling energy saving per unit conditioned roof area ranging from 3.30 kWh/m 2 in Alaska to 7.69 kWh/m 2 in Arizona (5.02 kWh/m 2 nationwide); a heating energy penalty ranging from 0.003 therm/m 2 in Hawaii to 0.14 therm/m 2 in Wyoming (0.065 therm/m 2 nationwide); and an energy cost saving ranging from USD 0.126/m 2 in West Virginia to USD 1.14/m 2 in Arizona (USD 0.356/m 2 nationwide). It also offered annually a CO2 reduction ranging from 1.07 kg/m 2 in Alaska to 4.97 kg/m 2 in Hawaii (3.02 kg/m 2 nationwide); an NOx reduction ranging from 1.70 g/m 2 in New York to 11.7 g/m 2 in Hawaii (4.81 g/m 2 nationwide); an SO2 reduction ranging from 1.79 g/m 2 in California to 26.1 g/m 2 in Alabama (12.4 g/m 2 nationwide); and an Hg reduction ranging from 1.08 μg/m 2 in Alaska to 105 μg/m 2 in Alabama (61.2 μg/m 2 nationwide). Retrofitting 80% of the 2

  17. Estimating the cost of saving electricity through U.S. utility customer-funded energy efficiency programs

    International Nuclear Information System (INIS)

    Hoffman, Ian M.; Goldman, Charles A.; Rybka, Gregory; Leventis, Greg; Schwartz, Lisa; Sanstad, Alan H.; Schiller, Steven

    2017-01-01

    The program administrator and total cost of saved energy allow comparison of the cost of efficiency across utilities, states, and program types, and can identify potential performance improvements. Comparing program administrator cost with the total cost of saved energy can indicate the degree to which programs leverage investment by participants. Based on reported total costs and savings information for U.S. utility efficiency programs from 2009 to 2013, we estimate the savings-weighted average total cost of saved electricity across 20 states at $0.046 per kilowatt-hour (kW h), comparing favorably with energy supply costs and retail rates. Programs targeted on the residential market averaged $0.030 per kW h compared to $0.053 per kW h for non-residential programs. Lighting programs, with an average total cost of $0.018 per kW h, drove lower savings costs in the residential market. We provide estimates for the most common program types and find that program administrators and participants on average are splitting the costs of efficiency in half. More consistent, standardized and complete reporting on efficiency programs is needed. Differing definitions and quantification of costs, savings and savings lifetimes pose challenges for comparing program results. Reducing these uncertainties could increase confidence in efficiency as a resource among planners and policymakers. - Highlights: • The cost of saved energy allows comparisons among energy resource investments. • Findings from the most expansive collection yet of total energy efficiency program costs. • The weighted average total cost of saved electricity was $0.046 for 20 states in 2009–2013. • Averages in the residential and non-residential sectors were $0.030 and $0.053 per kW h, respectively. • Results strongly indicate need for more consistent, reliable and complete reporting on efficiency programs.

  18. Potential for chlorate interference in ion chromatographic determination of total nitrogen in natural waters following alkaline persulfate digestion.

    Science.gov (United States)

    Halstead, J A; Edwards, J; Soracco, R J; Armstrong, R W

    1999-10-01

    Determination of total nitrogen in aqueous samples after thermal potassium peroxydisulfate (persulfate) digestion is a commonly used alternative to the tedious Kjeldahl procedure. When ion chromatography is used to quantify the nitrate formed during digestion, there is a potential for interference from a chlorate peak if the digested sample initially contained chloride in concentrations close to or greater than the concentration of nitrogen. It was determined that this interference can be avoided either by using chromatographic conditions which cleanly resolve the nitrate and chlorate peaks (e.g., the Dionex AG9-HG column) or by using digestion reagent concentrations chosen to maintain a high pH throughout the digestion. The second alternative is not a viable option for investigators using a single digestion for both total nitrogen (TN) and total phosphorus (TP) analysis.

  19. Total energy and potential enstrophy conserving schemes for the shallow water equations using Hamiltonian methods - Part 1: Derivation and properties

    Science.gov (United States)

    Eldred, Christopher; Randall, David

    2017-02-01

    The shallow water equations provide a useful analogue of the fully compressible Euler equations since they have similar characteristics: conservation laws, inertia-gravity and Rossby waves, and a (quasi-) balanced state. In order to obtain realistic simulation results, it is desirable that numerical models have discrete analogues of these properties. Two prototypical examples of such schemes are the 1981 Arakawa and Lamb (AL81) C-grid total energy and potential enstrophy conserving scheme, and the 2007 Salmon (S07) Z-grid total energy and potential enstrophy conserving scheme. Unfortunately, the AL81 scheme is restricted to logically square, orthogonal grids, and the S07 scheme is restricted to uniform square grids. The current work extends the AL81 scheme to arbitrary non-orthogonal polygonal grids and the S07 scheme to arbitrary orthogonal spherical polygonal grids in a manner that allows for both total energy and potential enstrophy conservation, by combining Hamiltonian methods (work done by Salmon, Gassmann, Dubos, and others) and discrete exterior calculus (Thuburn, Cotter, Dubos, Ringler, Skamarock, Klemp, and others). Detailed results of the schemes applied to standard test cases are deferred to part 2 of this series of papers.

  20. Electric power saving potential due to domestic refrigerators replacement; Potencial de ahorro de energia electrica por el reemplazo de refrigeradores domesticos

    Energy Technology Data Exchange (ETDEWEB)

    Peralta Solorio, Jose Luis [Fideicomiso para el Ahorro de Energia Electrica (Mexico)]. E-mail: jose.peralta@cfe.gob.mx

    2006-04-15

    In Mexico the second most used electrical appliance is: refrigerator. Owing to its use, it would be a promising option for electric power saving. In Guadalajara, Reynosa and Tampico it was performed a study with the aim of launching a project to replace the old refrigerators with new ones which are more effective and less expensive. Since the refrigerators cost and the electrical invoicing saving, the electric appliance change is profitable. To expect with this replacement more than eight million of refrigerators manufactured before 1997 will be changed. [Spanish] El refrigerador es el segundo electrodomestico mas utilizado a nivel nacional, esto permite que debido a su uso sea una opcion prometedora para el ahorro de energia electrica. Se hizo un estudio en Guadalajara, Reynosa y Tampico con el fin de lanzar un proyecto para sustituir los refrigeradores viejos por unos nuevos que sean mas eficaces y menos costosos. Por el costo de los refrigeradores y el ahorro en la facturacion electrica, el cambio de electrodomestico es rentable, de esta manera se espera que los mas de ocho millones de refrigeradores fabricados antes de 1997 que existen en el pais sean cambiados.

  1. VA Telemedicine: An Analysis of Cost and Time Savings.

    Science.gov (United States)

    Russo, Jack E; McCool, Ryan R; Davies, Louise

    2016-03-01

    The Veterans Affairs (VA) healthcare system provides beneficiary travel reimbursement ("travel pay") to qualifying patients for traveling to appointments. Travel pay is a large expense for the VA and hence the U.S. Government, projected to cost nearly $1 billion in 2015. Telemedicine in the VA system has the potential to save money by reducing patient travel and thus the amount of travel pay disbursed. In this study, we quantify this savings and also report trends in VA telemedicine volumes over time. All telemedicine visits based at the VA Hospital in White River Junction, VT between 2005 and 2013 were reviewed (5,695 visits). Travel distance and time saved as a result of telemedicine were calculated. Clinical volume in the mental health department, which has had the longest participation in telemedicine, was analyzed. Telemedicine resulted in an average travel savings of 145 miles and 142 min per visit. This led to an average travel payment savings of $18,555 per year. Telemedicine volume grew significantly over the study period such that by the final year the travel pay savings had increased to $63,804, or about 3.5% of the total travel pay disbursement for that year. The number of mental health telemedicine visits rose over the study period but remained small relative to the number of face-to-face visits. A higher proportion of telemedicine visits involved new patients. Telemedicine at the VA saves travel distance and time, although the reduction in travel payments remains modest at current telemedicine volumes.

  2. Save Energy Now Assessments Results 2008 Detailed Report

    Energy Technology Data Exchange (ETDEWEB)

    Wright, Anthony L [ORNL; Martin, Michaela A [ORNL; Nimbalkar, Sachin U [ORNL; Quinn, James [U.S. Department of Energy; Glatt, Ms. Sandy [DOE Industrial Technologies Program; Orthwein, Mr. Bill [U.S. Department of Energy

    2010-09-01

    independently replicate the assessment process at the company's other facilities. Another important element of the Save Energy Now assessment process is the follow-up process used to identify how many of the recommended savings opportunities from individual assessments have been implemented in the industrial plants. Plant personnel involved with the Save Energy Now assessments are contacted 6 months, 12 months, and 24 months after individual assessments are completed to determine implementation results. A total of 260 Save Energy Now assessments were successfully completed in calendar year 2008. This means that a total of 718 assessments were completed in 2006, 2007, and 2008. As of July 2009, we have received a total of 239 summary reports from the ESAs that were conducted in year 2008. Hence, at the time that this report was prepared, 680 final assessment reports were completed (200 from year 2006, 241 from year 2007, and 239 from year 2008). The total identified potential cost savings from these 680 assessments is $1.1 billion per year, including natural gas savings of about 98 TBtu per year. These results, if fully implemented, could reduce CO{sub 2} emissions by about 8.9 million metric tons annually. When this report was prepared, data on implementation of recommended energy and cost savings measures from 488 Save Energy Now assessments were available. For these 488 plants, measures saving a total of $147 million per year have been implemented, measures that will save $169 million per year are in the process of being implemented, and plants are planning implementation of measures that will save another $239 million per year. The implemented recommendations are already achieving total CO{sub 2} reductions of about 1.8 million metric tons per year. This report provides a summary of the key results for the Save Energy Now assessments completed in 2008; details of the 6-month, 12-month, and 24-month implementation results obtained to date; and an evaluation of these

  3. The K + - Nucleus Microscopic Optical Potential and Calculations of the Corresponding Differential Elastic and Total Reaction Cross Sections

    International Nuclear Information System (INIS)

    Zemlyanaya, E.V.; Lukyanov, K.V.; Lukyanov, V.K.; Hanna, K.M.

    2009-01-01

    The microscopic optical potential (OP) is calculated for the K+-meson scattering on the 12 C and 40 Ca nuclei at intermediate energies. This potential has no free parameters and based on the known kaon-nucleon amplitude and nuclear density distribution functions. Then, the Klein-Gordon equation is written in the form of the relativistic Schrodinger equation where terms quadratic in the potential was estimated can be neglected. The latter equations adapted to the considered task and solved numerically. The effect of revitalization is shown to play a significant role. A good agreement with the experimental data on differential elastic cross sections is obtained. However, to explain the data on total reaction cross sections the additional surface term of OP was introduced to account for influence of the peripheral nuclear reaction channels

  4. Energy saving certificates

    International Nuclear Information System (INIS)

    2005-11-01

    The French ministry of economy, finances and industry and the French agency of environment and energy mastery (Ademe) have organized on November 8, 2005, a colloquium for the presentation of the energy saving certificates, a new tool to oblige the energy suppliers to encourage their clients to make energy savings. This document gathers the transparencies presented at this colloquium about the following topics: state-of-the-art and presentation of the energy saving certificates system: presentation of the EEC system, presentation of the EEC standard operations; the energy saving certificates in Europe today: energy efficiency commitment in UK, Italian white certificate scheme, perspectives of the different European systems. (J.S.)

  5. Spending to save

    DEFF Research Database (Denmark)

    Larsen, Anders

    2013-01-01

    the energy distribution companies meet their overall saving obligation, the net savings impact are about a third of the savings reported by the obligated parties. Further it was found that while energy savings in the public and business sector have a high net impact, some subsidies given under the EEO...... perspective. The evaluation has resulted in noticeable adjustments of the design of the Danish EEO, e.g. introduction of a 1 year payback-time limit for projects receiving subsidies, a minimum baseline for insulation products, and specification of documentation requirements....

  6. Biogenic Methane Generation Potential in the Eastern Nankai Trough, Japan: Effect of Reaction Temperature and Total Organic Carbon

    Science.gov (United States)

    Aung, T. T.; Fujii, T.; Amo, M.; Suzuki, K.

    2017-12-01

    Understanding potential of methane flux from the Pleistocene fore-arc basin filled turbiditic sedimentary formation along the eastern Nankai Trough is important in the quantitative assessment of gas hydrate resources. We considered generated methane could exist in sedimentary basin in the forms of three major components, and those are methane in methane hydrate, free gas and methane dissolved in water. Generation of biomethane strongly depends on microbe activity and microbes in turn survive in diverse range of temperature, salinity and pH. This study aims to understand effect of reaction temperature and total organic carbon on generation of biomethane and its components. Biomarker analysis and cultural experiment results of the core samples from the eastern Nankai Trough reveal that methane generation rate gets peak at various temperature ranging12.5°to 35°. Simulation study of biomethane generation was made using commercial basin scale simulator, PetroMod, with different reaction temperature and total organic carbon to predict how these effect on generation of biomethane. Reaction model is set by Gaussian distribution with constant hydrogen index and standard deviation of 1. Series of simulation cases with peak reaction temperature ranging 12.5°to 35° and total organic carbon of 0.6% to 3% were conducted and analyzed. Simulation results show that linear decrease in generation potential while increasing reaction temperature. But decreasing amount becomes larger in the model with higher total organic carbon. At higher reaction temperatures, >30°, extremely low generation potential was found. This is due to the fact that the source formation modeled is less than 1 km in thickness and most of formation do not reach temperature more than 30°. In terms of the components, methane in methane hydrate and free methane increase with increasing TOC. Drastic increase in free methane was observed in the model with 3% of TOC. Methane amount dissolved in water shows almost

  7. Energy saving potential of energy services - experimentation on the life cycle of energy conversion equipment; Potentiel d'economies d'energie par les services energetiques - application au cycle de vie des equipements de conversion de l'energie

    Energy Technology Data Exchange (ETDEWEB)

    Dupont, M

    2006-12-15

    Energy efficiency services are growing in Europe but their role is still limited. In order to evaluate the potential, we focused first of all on policy, economical and environmental mechanisms that support their development. European natural gas and electricity markets, that are now almost wholly de-regulated, are analysed and compared to their historical structure. By introducing uncertainty on energy prices, this new deal translates better the real energy costs. Energy performance contracts (EPC) limit the impact of these uncertainties on the customer energy bills by guaranteeing a financial result. As a result of the modelling of these contracts, namely operation and maintenance ones, we prove that they transfer technical and financial risks from building owners to energy service companies (ESCO) making energy saving measures easier and less expensive at the same time. These contracts are relatively widespread for heating or compressed-air processes but remain marginal for air-conditioning systems. So new methods were needed to guarantee on the long terms the efficiency of air-conditioning systems demand (1) to master the process and its performances and (2) to be able to determine precisely the energy saving potential and its realisation costs. A detailed energy audit is thus necessary for which we propose a guidance. Conclusions of audits carried out prove that energy saving potential is mainly located in equipment management and control. These optimizations are not always carried out because of a lack of contractual incentive and due to the weaknesses of audit methods. Through the involvement of an independent expert, the mandatory and regular inspection of air-conditioning systems may allow to verify and guide such practices. A three-step analysis procedure has been developed in order to maximize the inspection potential and to get higher benefits from service contracts. (author)

  8. Evaluation of the energy saving potential in illumination using presence sensors; Evaluacion del potencial de ahorro de energia en iluminacion utilizando sensores de presencia

    Energy Technology Data Exchange (ETDEWEB)

    Cortes Eslava, Alejandro [Universidad Nacional Autonoma de Mexico (UNAM), Mexico, D. F. (Mexico)

    1999-07-01

    The analysis and the evaluation of the energy saving that would provide a system of illumination controlled by sensors of presence in an enclosure with low transit, evaluating the economic profitability of the system is presented. The data, from which the analysis is sustained and the results are deducted, coming from the use and installation of a timer in the area. [Spanish] Se presenta el analisis y la evaluacion de los ahorros de energia que suministraria un sistema de iluminacion controlado por sensores de presencia en un recinto con bajo transito, evaluando la rentabilidad economica del sistema. Los datos, a partir de los cuales se sustenta el analisis y se deducen los resultados, provienen de la utilizacion e instalacion de un contador de tiempo de uso en el recinto.

  9. Caustic saving potentile in textile processing mills

    International Nuclear Information System (INIS)

    Latif, M.; Rehman, A.; Ghafar, A.; Hafeez, N.M.

    2010-01-01

    The textile processing industry of pakistan has great potential of improvement in resource consumption in various production processes. One major concern is the heavy usage of caustic soda (sodium hydroxide) especially during the mercerization process which incurs a significant cost to a textile processing mill. To reduce the unit fabric production cost and stay competitive, the industry need to minimize the caustic wastage and explore the caustic saving potential. This paper describe the detailed caustic consumption practices and saving potentials in woven textile sector based on the data base of 100 industries. Region wise caustic saving potential is also investigated . Three caustic conservation option including process improvement, reuse and recycling, and caustic recovery plants are discussed. Detailed technical and and financial requirements. saving potentials and paybacks of these options are provided. (author)

  10. Energy Savings Lifetimes and Persistence

    Energy Technology Data Exchange (ETDEWEB)

    Hoffman, Ian M. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Schiller, Steven R. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Todd, Annika [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Billingsley, Megan A. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Goldman, Charles A. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Schwartz, Lisa C. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2016-02-01

    This technical brief explains the concepts of energy savings lifetimes and savings persistence and discusses how program administrators use these factors to calculate savings for efficiency measures, programs and portfolios. Savings lifetime is the length of time that one or more energy efficiency measures or activities save energy, and savings persistence is the change in savings throughout the functional life of a given efficiency measure or activity. Savings lifetimes are essential for assessing the lifecycle benefits and cost effectiveness of efficiency activities and for forecasting loads in resource planning. The brief also provides estimates of savings lifetimes derived from a national collection of costs and savings for electric efficiency programs and portfolios.

  11. Absence of a Scott correction for the total binding energy of noninteracting fermions in a smooth potential well

    International Nuclear Information System (INIS)

    Huxtable, B.D.

    1988-01-01

    It is shown, for V in a particular class of smooth functions, that the total binding energy, E(Z), of Z noninteracting Fermions in the potential well Z 4/3 V(Z 1/3 X) obeys E(Z) = c TF (V)Z 7/3 + O(Z 5/3 ) as Z → ∞. Here c TF (V) is the coefficient predicted by Thomas-Fermi theory. This result is consistent with the conjectured Scott correction, which occurs at order Z 2 , to the total binding energy of an atomic number Z. This correction is thought to arise only because V(x)∼ - |x| -1 near x = 0 in the atomic problem, and so V is not a smooth function

  12. Contract saving schemes

    NARCIS (Netherlands)

    Ronald, R.; Smith, S.J.; Elsinga, M.; Eng, O.S.; Fox O'Mahony, L.; Wachter, S.

    2012-01-01

    Contractual saving schemes for housing are institutionalised savings programmes normally linked to rights to loans for home purchase. They are diverse types as they have been developed differently in each national context, but normally fall into categories of open, closed, compulsory, and ‘free

  13. Estimated incident cost savings in shipping due to inspections.

    Science.gov (United States)

    Knapp, Sabine; Bijwaard, Govert; Heij, Christiaan

    2011-07-01

    The effectiveness of safety inspections of ships has been analysed from various angles, but until now, relatively little attention has been given to translate risk reduction into incident cost savings. This paper provides a monetary quantification of the cost savings that can be attributed to port state control inspections and industry vetting inspections. The dataset consists of more than half a million ship arrivals between 2002 and 2007 and contains inspections of port state authorities in the USA and Australia and of three industry vetting regimes. The effect of inspections in reducing the risk of total loss accidents is estimated by means of duration models, in terms of the gained probability of survival. The monetary benefit of port state control inspections is estimated to range, on average, from about 70 to 190 thousand dollars, with median values ranging from about 20 to 45 thousand dollars. Industry inspections have even higher benefits, especially for tankers. The savings are in general higher for older and larger vessels, and also for vessels with undefined flag and unknown classification society. As inspection costs are relatively low in comparison to potential cost savings, the results underline the importance of determining ships with relatively high risk of total loss. Copyright © 2011 Elsevier Ltd. All rights reserved.

  14. Site preparation savings through better utilization standards

    Science.gov (United States)

    W.F. Watson; B.J. Stokes; I.W. Savelle

    1984-01-01

    This reports preliminary paper results of a study to determine the savings in the cost of site preparation that can be accomplished by the intensive utiliiation of understory biomass. mechanized sys terns can potentially be used for recovering this material.

  15. The School Advanced Ventilation Engineering Software (SAVES)

    Science.gov (United States)

    The School Advanced Ventilation Engineering Software (SAVES) package is a tool to help school designers assess the potential financial payback and indoor humidity control benefits of Energy Recovery Ventilation (ERV) systems for school applications.

  16. Revolving fund for energy saving

    International Nuclear Information System (INIS)

    Prebensen, K.

    1993-01-01

    A key issue in Eastern Europe is the adjustment of prices from the former COMECON level to a level conforming with free market conditions. In the case of household heating, this issue involves the removal of government subsidies leading to sharply increasing prices, metering of individual consumption, improving the efficiency of energy production, distribution and use - where savings of 30-50% in each link are technically feasible - thereby providing a potential for a adapting consumption patterns to higher energy prices, provided that funds are available. Currently, investment in commercial heat production and distribution systems have received substantial international support - whereas investment in reduction of demand has been little exploited. The Revolving Fund for Energy Savings in Polish Households is a concept for efficient financing of small-scale projects. It aims at financing, on the level of housing cooperatives, on the basis of a simplified lending and project evaluation procedure, well suited to current Polish conditions or an organizationally and financially weak banking system and little developed technical knowledge in the field of energy saving. A general introduction to the issue is given and technical problems are elaborated. The implementation of Energy Savings in Housing seen from the banking point of view, and a current pilot scheme for financing, are described. (AB)

  17. Estimated potential of energy saving and reduction of the demand commercial buildings illumination; Potencial estimado de ahorro de energia y reduccion de la demanda en iluminacion de edificios comerciales

    Energy Technology Data Exchange (ETDEWEB)

    Hernandez Gomez, Victor Hugo; Morillon Galvez, David [Posgrado en Energetica de la DEPFI-UNAM, Mexico, D. F. (Mexico)

    1999-07-01

    In this paper the estimated energy saving potential in illumination, the energy end use and the technology used in commercial buildings of different use is analyzed. Estimation that departs from information of the Fideicomiso para el Ahorro de Energia (FIDE) demonstrative cases, presents the energy saving and the demand reduction in a sample of 29 buildings, among which are shopping malls, hospitals, schools, hotels, restaurants and public buildings in which energy saving programs have been carried out, with measures such as the cleaning of the luminaries and its replacement for more efficient ones. The average saving obtained is of 21.81%, in the following areas: illumination, air conditioning and others. In addition, in a sample of 4 buildings, it was observed that before applying the energy saving programs, two of them did not fulfill with the norm NOM-007-1995 (electric power density in interior lighting systems W/m{sup 2}) and later did fulfill the values and criteria of the norm. [Spanish] En el presente trabajo se analiza el potencial estimado de ahorro de energia en iluminacion, el uso final de la energia y la tecnologia empleada en edificios comerciales de uso distinto. Estimacion que parte de la informacion de los casos demostrativos del Fideicomiso para el Ahorro de Energia (FIDE), se presenta el ahorro y reduccion de la demanda en una muestra de 29 edificios, entre los que se tienen centros comerciales, hospitales, escuelas, hoteles, restaurantes y edificios publicos en los cuales se ha llevado a cabo programas de ahorro de energia, con medidas como la limpieza de las luminarias y su remplazo por otros mas eficientes. El ahorro promedio obtenido es de 21.81%, en las siguientes areas: iluminacion, aire acondicionado y otros. Ademas, en una muestra de 4 edificios, se observo que antes de aplicar los programas de ahorro de energia, dos no cumplian con la norma NOM-007-ENER-1995 (densidad de potencia electrica en alumbrado interior W/m{sup 2}) y

  18. The total pregnancy potential per oocyte aspiration after assisted reproduction-in how many cycles are biologically competent oocytes available?

    Science.gov (United States)

    Lemmen, J G; Rodríguez, N M; Andreasen, L D; Loft, A; Ziebe, S

    2016-07-01

    While stimulation of women prior to assisted reproduction is associated with increased success rates, the total biological pregnancy potential per stimulation cycle is rarely assessed. Retrospective sequential cohort study of the cumulative live birth rate in 1148 first IVF/ICSI-cycles and 5-year follow up of frozen embryo replacement (FER) cycles were used. Oocyte number, number of embryos transferred, and cryopreserved/thawed and transferred embryos in a FER cycle were registered for all patients. Children per oocyte and per transferred embryo and percentage of cycles with births were calculated. We obtained 9529 oocytes. Embryos (2507) were transferred in either fresh or FER cycles, resulting in 422 births and 474 live born children. Median age of the women was 32.5 years (range 20-41.5 years). In total, 34.3 % of all cycles ended with a live birth while in 65.7 % of the cycles, no oocytes were capable of developing into a child. The average number of oocytes needed per live born child after transfer of fresh and thawed embryos was 20 as only 5.0 % of oocytes aspirated in the first IVF/ICSI cycle had the competence to develop into a child. In our setting, overall 5.0 % of the oocytes in a first cycle were biologically competent and in around 2/3 of all cycles, none of the oocytes had the potential to result in the birth of a child.

  19. Electricity savings ``soon come'' to Jamaica -- Assessing the potential for air conditioning and refrigeration end-use DSM

    Energy Technology Data Exchange (ETDEWEB)

    Conlon, T.; Hamzawi, E.; Campbell, V.

    1998-07-01

    With the support of the Inter-American Development Bank, the Global Environment Facility of the World Bank, and the Rockefeller Foundation, the national electric utility in Jamaica (Jamaica Public Service Company) has begun an assessment of the technical, economic, and financial opportunities for achieving demand-side management (DSM) energy savings in the air conditioning and refrigeration end uses. The feasibility and cost effectiveness of specific measures is being assessed for both the residential and commercials segments. While structures as a traditional load-research-based market assessment, the project uses ethnographic data collection and analysis techniques and involves collaboration with local contractors. The skills of local experts are being taped to identify and interview the key market players, and to develop an understanding of the barriers to and opportunities for energy efficiency present in the evolving equipment markets. The paper outlines methods and presents preliminary case study results for the air conditioning market. The authors identify major groups of market players and dominant types of equipment, and provide an overview of market dynamics. The volume of sales passing through both formal and informal distribution channels is estimated and market barriers are identified. Based on the findings of the study, recommendations will be made for future program and policy initiatives designed to mitigate selected barriers in each of the supply chains.

  20. Risk transfer via energy savings insurance

    Energy Technology Data Exchange (ETDEWEB)

    Mills, Evan

    2001-10-01

    Among the key barriers to investment in energy efficiency improvements are uncertainties about attaining projected energy savings and apprehension about potential disputes over these savings. The fields of energy management and risk management are thus intertwined. While many technical methods have emerged to manage performance risks (e.g. building commissioning), financial risk transfer techniques are less developed in the energy management arena than in other more mature segments of the economy. Energy Savings Insurance (ESI) - formal insurance of predicted energy savings - is one method of transferring financial risks away from the facility owner or energy services contractor. ESI offers a number of significant advantages over other forms of financial risk transfer, e.g. savings guarantees or performance bonds. ESI providers manage risk via pre-construction design review as well as post-construction commissioning and measurement and verification of savings. We found that the two mos t common criticisms of ESI - excessive pricing and onerous exclusions - are not born out in practice. In fact, if properly applied, ESI can potentially reduce the net cost of energy savings projects by reducing the interest rates charged by lenders, and by increasing the level of savings through quality control. Debt service can also be ensured by matching loan payments to projected energy savings while designing the insurance mechanism so that payments are made by the insurer in the event of a savings shortfall. We estimate the U.S. ESI market potential of $875 million/year in premium income. From an energy-policy perspective, ESI offers a number of potential benefits: ESI transfers performance risk from the balance sheet of the entity implementing the energy savings project, thereby freeing up capital otherwise needed to ''self-insure'' the savings. ESI reduces barriers to market entry of smaller energy services firms who do not have sufficiently strong balance

  1. Risk transfer via energy savings insurance; TOPICAL

    International Nuclear Information System (INIS)

    Mills, Evan

    2001-01-01

    Among the key barriers to investment in energy efficiency improvements are uncertainties about attaining projected energy savings and apprehension about potential disputes over these savings. The fields of energy management and risk management are thus intertwined. While many technical methods have emerged to manage performance risks (e.g. building commissioning), financial risk transfer techniques are less developed in the energy management arena than in other more mature segments of the economy. Energy Savings Insurance (ESI) - formal insurance of predicted energy savings - is one method of transferring financial risks away from the facility owner or energy services contractor. ESI offers a number of significant advantages over other forms of financial risk transfer, e.g. savings guarantees or performance bonds. ESI providers manage risk via pre-construction design review as well as post-construction commissioning and measurement and verification of savings. We found that the two mos t common criticisms of ESI - excessive pricing and onerous exclusions - are not born out in practice. In fact, if properly applied, ESI can potentially reduce the net cost of energy savings projects by reducing the interest rates charged by lenders, and by increasing the level of savings through quality control. Debt service can also be ensured by matching loan payments to projected energy savings while designing the insurance mechanism so that payments are made by the insurer in the event of a savings shortfall. We estimate the U.S. ESI market potential of$875 million/year in premium income. From an energy-policy perspective, ESI offers a number of potential benefits: ESI transfers performance risk from the balance sheet of the entity implementing the energy savings project, thereby freeing up capital otherwise needed to ''self-insure'' the savings. ESI reduces barriers to market entry of smaller energy services firms who do not have sufficiently strong balance sheets to self

  2. Saving gas project

    Energy Technology Data Exchange (ETDEWEB)

    Vasques, Maria Anunciacao S. [PETROBRAS S.A., Rio de Janeiro, RJ (Brazil); Garantizado, Maria Auxiliadora G. [CONCREMAT Engenharia, Rio de Janeiro, RJ (Brazil)

    2009-12-19

    The work presented was implemented in municipalities around the construction of the pipeline project Urucu-Coari-Manaus, the Engineering / IETEG-IENOR, because of the constant release of workers, consequently the finishing stages of this work and its future completion. The Project aims to guide saving gas with the workforce, their families and communities to the enterprise of small business cooperatives and solidarity within the potential of the site. This project is developed through the workshops: entrepreneur ship, tourism, use, reuse and recycling of products, and hortifruiti culture, agroecology, agribusiness (cooperativism solidarity) and forestry. Its execution took place in two phases, the first called 'pilot' of 12/12/2007 to 27/03/2008 in sections A and B1, in the municipality of Coari stretch and B2 in Caapiranga. The second phase occurred from 30/06 to 27/09/08, in the words B1, in the municipalities of Codajas and Anori words and B2 in Iranduba, Manacapuru and Anama. The workshops were held in state and municipal schools and administered by the Institute of Social and Environmental Amazon - ISAM, which had a team of coordinators, teachers, experts and masters of the time until the nineteen twenty-two hours to implement the project. (author)

  3. Save energy, without entropy

    International Nuclear Information System (INIS)

    Steinmeyer, D.

    1992-01-01

    When we talk about saving energy what we usually mean is not wasting work. What we try to do when we design a process, is to use work as effectively as possible. It's hard to do that if we can't see it clearly. This paper illustrates how work can be seen (or calculated) without imposing entropy as a screen in front of it. We've all heard that the second law tells us that the entropy of the universe is increasing, and we are left with the feeling that the universe is ultimately headed for chaos, but receive little other information from this statement. A slightly more useful statement of the second law is the work potential of the universe is decreasing. However, this statement carries a needlessly negative ring. A simplified definition of the second law is: It takes work to change things. With these two corollaries: We can calculate the theoretical minimum work needed for a given change; and We can express the value of all changes in terms of work

  4. Acute total sleep deprivation potentiates amphetamine-induced locomotor-stimulant effects and behavioral sensitization in mice.

    Science.gov (United States)

    Saito, Luis P; Fukushiro, Daniela F; Hollais, André W; Mári-Kawamoto, Elisa; Costa, Jacqueline M; Berro, Laís F; Aramini, Tatiana C F; Wuo-Silva, Raphael; Andersen, Monica L; Tufik, Sergio; Frussa-Filho, Roberto

    2014-02-01

    It has been demonstrated that a prolonged period (48 h) of paradoxical sleep deprivation (PSD) potentiates amphetamine (AMP)-induced behavioral sensitization, an animal model of addiction-related neuroadaptations. In the present study, we examined the effects of an acute short-term deprivation of total sleep (TSD) (6h) on AMP-induced behavioral sensitization in mice and compared them to the effects of short-term PSD (6 h). Three-month-old male C57BL/6J mice underwent TSD (experiment 1-gentle handling method) or PSD (experiment 2-multiple platforms method) for 6 h. Immediately after the sleep deprivation period, mice were tested in the open field for 10 min under the effects of saline or 2.0 mg/kg AMP. Seven days later, to assess behavioral sensitization, all of the mice received a challenge injection of 2.0 mg/kg AMP and were tested in the open field for 10 min. Total, peripheral, and central locomotion, and grooming duration were measured. TSD, but not PSD, potentiated the hyperlocomotion induced by an acute injection of AMP and this effect was due to an increased locomotion in the central squares of the apparatus. Similarly, TSD facilitated the development of AMP-induced sensitization, but only in the central locomotion parameter. The data indicate that an acute period of TSD may exacerbate the behavioral effects of AMP in mice. Because sleep architecture is composed of paradoxical and slow wave sleep, and 6-h PSD had no effects on AMP-induced hyperlocomotion or sensitization, our data suggest that the deprivation of slow wave sleep plays a critical role in the mechanisms that underlie the potentiating effects of TSD on both the acute and sensitized addiction-related responses to AMP. Copyright © 2013 Elsevier Inc. All rights reserved.

  5. Evaluation of trace organic contaminants in ultra-pure water production processes by measuring total organic halogen formation potential

    International Nuclear Information System (INIS)

    Urano, Kohei; Iwase, Yoko

    1984-01-01

    A new procedure for the determination of organic substances in water with high accuracy and high sensitivity was proposed, in which a hypochlorite is added to water, and the resultant total amount of organic halogen compounds (TOX formation potential) was measured, and it was applied to the evaluation of trace organic contaminants in ultra-pure water production process. In this investigation, the TOX formation potential of the raw water which was to be used for the ultra-pure water production process, intermediately treated water and ultra-pure water was measured to clarify the behavior of organic substances in the ultra-pure water production process and to demonstrate the usefulness of this procedure to evaluate trace organic contaminants in water. The measurement of TOX formation potential requires no specific technical skill, and only a short time, and gives accurate results, therefore, it is expected that the water quality control in the ultra-pure water production process can be performed more exactly by applying this procedure. (Yoshitake, I.)

  6. Invisible costs, visible savings.

    Science.gov (United States)

    Lefever, G

    1999-08-01

    By identifying hidden inventory costs, nurse managers can save money for the organization. Some measures include tracking and standardizing supplies, accurately evaluating patients' needs, and making informed purchasing decisions.

  7. Realized Cost Savings 2016

    Data.gov (United States)

    Department of Veterans Affairs — This dataset is provided as a requirement of OMB’s Integrated Data Collection (IDC) and links to VA’s Realized Cost Savings and Avoidances data in JSON format. Cost...

  8. The modern water-saving agricultural technology: Progress and focus

    African Journals Online (AJOL)

    GREGORY

    2010-09-13

    Sep 13, 2010 ... DEVELOPING TENDENCY OF MODERN WATER-. SAVING AGRICULTURAL TECHNOLOGY. Excavation of the own water-saving potential using biotechnology. The biological water-saving technology that uses crop physiology control and modern breeding techniques to increase production and water ...

  9. Total antioxidant potential of resinous exudates from Heliotropium species, and a comparison of the ABTS and DPPH methods.

    Science.gov (United States)

    Lissi, E A; Modak, B; Torres, R; Escobar, J; Urzua, A

    1999-06-01

    Total reactive antioxidant potential (TRAP) of resinous exudates from Heliotropium species was evaluated by measuring the bleaching of stable free radicals. The antioxidant capacity of the resinous exudates in Trolox equivalents, evaluated from the bleaching of ABTS derived radical cations, ranged from 2.0 M (H. huascoense) to 5.2 M (H. stenophyllum), indicating a very high concentration of phenolic compounds. Considerably smaller values were obtained by measuring the bleaching of DPPH radicals. The ratio between the values obtained employing ABTS derived radicals and DPPH, ranged from 37 (H. megalanthum) to 4.5 (H. chenopodiaceum variety typica). The magnitude of the difference can be considered as an indication of the relative reactivity of the antioxidants present in the exudates. Similar ratios were observed when stoichiometric coefficients were evaluated for representative purified flavonoids obtained from the resinous exudates.

  10. Methodology used for total system performance assessment of the potential nuclear waste repository at yucca mountain (USA)

    International Nuclear Information System (INIS)

    Devonec, E.; Sevougian, S.D.; Mattie, P.D.; Mcneish, J.A.; Mishra, S.

    2001-01-01

    The U.S. Department of Energy and its contractors are currently evaluating a site in Nevada (Yucca Mountain) for disposal of high-level radioactive waste from U.S. commercial nuclear plants and U.S. government-owned facilities. The suitability of the potential geologic repository is assessed, based on its performance in isolating the nuclear waste from the environment. Experimental data and models representing the natural and engineered barriers are combined into a Total System Performance Assessment (TSPA) model. Because of the uncertainty in the current data and in the future evolution of the total system, simulations follow a probabilistic approach. Multiple realization simulations using Monte Carlo analysis are conducted over time periods of up to one million years, which estimates a range of possible behaviors of the repository. In addition to the nominal scenario, other exposure scenarios include the possibility of disruptive events such as volcanic eruption or intrusion, or accidental human intrusion. Sensitivity to key uncertain processes is analyzed. The influence of stochastic variables on the TSPA model output is assessed by ''uncertainty importance analysis'', e.g., regression analysis and classification tree analysis. Further investigation of the impact of parameters and assumptions is conducted through ''one-off analysis'', which consists in fixing a parameter at a particular value, using an alternative conceptual model, or in making a different assumption. Finally, robustness analysis evaluates the performance of the repository when various natural or engineered barriers are assumed to be degraded. The objective of these analyses is to evaluate the performance of the potential repository system under conditions ranging from expected to highly unlikely, though physically possible conditions. (author)

  11. Methodology used for total system performance assessment of the potential nuclear waste repository at yucca mountain (USA)

    Energy Technology Data Exchange (ETDEWEB)

    Devonec, E.; Sevougian, S.D.; Mattie, P.D.; Mcneish, J.A. [Duke Engineering and Services, Town Center Drive, Las Vegas (United States); Mishra, S. [Duke Engineering and Services, Austin, TX (United States)

    2001-07-01

    The U.S. Department of Energy and its contractors are currently evaluating a site in Nevada (Yucca Mountain) for disposal of high-level radioactive waste from U.S. commercial nuclear plants and U.S. government-owned facilities. The suitability of the potential geologic repository is assessed, based on its performance in isolating the nuclear waste from the environment. Experimental data and models representing the natural and engineered barriers are combined into a Total System Performance Assessment (TSPA) model. Because of the uncertainty in the current data and in the future evolution of the total system, simulations follow a probabilistic approach. Multiple realization simulations using Monte Carlo analysis are conducted over time periods of up to one million years, which estimates a range of possible behaviors of the repository. In addition to the nominal scenario, other exposure scenarios include the possibility of disruptive events such as volcanic eruption or intrusion, or accidental human intrusion. Sensitivity to key uncertain processes is analyzed. The influence of stochastic variables on the TSPA model output is assessed by ''uncertainty importance analysis'', e.g., regression analysis and classification tree analysis. Further investigation of the impact of parameters and assumptions is conducted through ''one-off analysis'', which consists in fixing a parameter at a particular value, using an alternative conceptual model, or in making a different assumption. Finally, robustness analysis evaluates the performance of the repository when various natural or engineered barriers are assumed to be degraded. The objective of these analyses is to evaluate the performance of the potential repository system under conditions ranging from expected to highly unlikely, though physically possible conditions. (author)

  12. Synthesis and Summary Report on State of the Art, Drivers and Stakeholders of Energy Efficiency in Agricullture, and Potential of Energy Saving Measures

    NARCIS (Netherlands)

    Visser, de C.L.M.; Buisonje, de F.E.; Ellen, H.H.; Stanghellini, C.; Voort, van der M.P.J.

    2012-01-01

    Improvements in the energy efficiency of agricultural production have the potential to significantly reduce energy inputs and thereby reducing production costs and greenhouse gas emissions. Energy efficiency analysis depicts the distribution of energy inputs in a given agricultural production system

  13. Methodology Used for Total System Performance Assessment of the Potential Nuclear Waste Repository at Yucca Mountain (USA)

    International Nuclear Information System (INIS)

    E. Devibec; S.D. Sevougian; P.D. Mattie; J.A. McNeish; S. Mishra

    2001-01-01

    The U.S. Department of Energy and its contractors are currently evaluating a site in Nevada (Yucca Mountain) for disposal of high-level radioactive waste from U.S. commercial nuclear plants and U.S. government-owned facilities. The suitability of the potential geologic repository is assessed, based on its performance in isolating the nuclear waste from the environment. Experimental data and models representing the natural and engineered barriers are combined into a Total System Performance Assessment (TSPA) model [1]. Process models included in the TSPA model are unsaturated zone flow and transport, thermal hydrology, in-drift geochemistry, waste package degradation, waste form degradation, engineered barrier system transport, saturated zone flow and transport, and biosphere transport. Because of the uncertainty in the current data and in the future evolution of the total system, simulations follow a probabilistic approach. Multiple realization simulations using Monte Carlo analysis are conducted over time periods of up to one million years, which estimates a range of possible behaviors of the repository. The environmental impact is measured primarily by the annual dose received by an average member of a critical population group residing 20 km down-gradient of the potential repository. In addition to the nominal scenario, other exposure scenarios include the possibility of disruptive events such as volcanic eruption or intrusion, or accidental human intrusion. Sensitivity to key uncertain processes is analyzed. The influence of stochastic variables on the TSPA model output is assessed by ''uncertainty importance analysis'', e.g., regression analysis and classification tree analysis. Further investigation of the impact of parameters and assumptions is conducted through ''one-off analysis'', which consists in fixing a parameter at a particular value, using an alternative conceptual model, or in making a different assumption. Finally, robustness analysis evaluates

  14. Estimating potential for savings for low risk endometrial cancer using the Endometrial Cancer Alternative Payment Model (ECAP): A companion paper to the Society of Gynecologic Oncology Report on the Endometrial Cancer Alternative Payment Model.

    Science.gov (United States)

    Wright, Jason D; Havrilesky, Laura J; Cohn, David E; Huang, Yongmei; Rathbun, Jill; Rice, Laurel W; Brown, Carol L; Alvarez, Ronald D; Ko, Emily M

    2018-05-01

    To design an endometrial cancer (EC) alternative payment (ECAP) model focused on surgical management of EC, as well as identify drivers of cost in order to develop opportunities for cost-savings while maintaining quality of care. National practice patterns and reimbursements were compared between private payers (MarketScan data, years 2009-13) and public payers (Medicare, year 2014) of EC patients who underwent hysterectomy. An episode of care for EC included the hysterectomy, stratified by surgical approach (laparotomy versus robotic versus laparoscopy), and in- and outpatient reimbursements from 30days preoperatively to 60days postoperatively. Reimbursements were categorized into cost centers. A decision model informed modifiable components influencing overall reimbursements for EC surgical care. Variations in length of stay (LOS), emergency department (ED visits), and readmissions were analyzed to create an optimal care model. A total of MarketScan (n=29,558) and Medicare (n=377) patients were included. Mean total reimbursement for an episode of care was $19,183 (SD $10,844) for Medicare and $30,839 (SD $19,911) for MarketScan. Mean reimbursements were greatest for abdominal cases in Medicare ($25,553; SD $11,870) and MarketScan ($35,357; SD $21,670), followed by robotic and laparoscopic. Among MarketScan patients, 7.6% of women were readmitted within 60days after surgery and 11.7% had an evaluation in the ED. The median reimbursement per patient for readmission was $14,474 (IQR $8584 to $26,149), and for ED visit was $6327 (IQR $1369 to $29,153). In an optimized care model, increasing the rate of minimally invasive surgery by 5% while reducing LOS by 10% and ED visits/readmissions by 10%, lowered the average case reimbursement by $903 (2.9%) for MarketScan and $1243 (5.9%) for Medicare. An ECAP model demonstrates that reimbursements vary by public versus commercial payers in the U.S. for the surgical management of endometrial cancer patients, and that

  15. Risk transfer via energy savings insurance

    OpenAIRE

    Mills, Evan

    2001-01-01

    Among the key barriers to investment in energy efficiency improvements are uncertainties about attaining projected energy savings and apprehension about potential disputes over these savings. The fields of energy management and risk management are thus intertwined. While many technical methods have emerged to manage performance risks (e.g. building commissioning), financial risk transfer techniques are less developed in the energy management arena than in other more mature segments of t...

  16. Effect of hydrothermal processing on total polyphenolics and antioxidant potential of underutilized leafy vegetables, Boerhaavia diffusa and Portulaca oleracea

    Science.gov (United States)

    Nagarani, Gunasekaran; Abirami, Arumugam; Nikitha, Prasad; Siddhuraju, Perumal

    2014-01-01

    Objective To investigate the effect of different processing methods on antioxidant properties of acetone extract of aerial parts from Boerhaavia diffusa and Portulaca oleracea. Methods The total phenolic and flavonoid contents were determined by Folin-Ciocalteau and aluminum chloride method, respectively. FRAP, metal chelating activity, DPPH, ABTS, nitric oxide, hydroxyl and superoxide radical scavenging activities, carotene/linoleic acid bleaching activity were used for the determination of antioxidant capacity. Results The total phenolics in Boerhaavia diffusa (82.79-162.80 mg GAE/g extract) were found to be higher when compared to that of Portulaca oleracea (22.94-10.02 mg GAE/g extract). Hydrothermal processing enhanced the level of inhibition on synthetic radicals such as DPPH (3 439-309 549 mmol TE/g extract) and ABTS (17 808-53 818 mmol TE/g extract) as well as biologically relevant radicals such as superoxide anion (70%-90%) and nitric oxide (49%-57%). In addition, boiling of the vegetables were found to be maximum capacity of FRAP (6 404.95 mmol Fe (II)/g extract) and metal chelating activity (1.53 mg EDTA/g extract) than the respective raw samples. Conclusions The present investigation suggests that the processing enhance the functionality and improves the availability of bioactive substances of these vegetables. In addition, they also exhibited more potent antioxidant activity. Therefore these natural weeds from the crop land ecosystem could be suggested as cost effective indigenous green vegetables for human diet and potential feed resources for animals. Further extensive studies on role and importance of those weeds in sustaining the agro biodiversity are also needed. PMID:25183131

  17. Rotavirus diarrhea disease burden in Peru: the need for a rotavirus vaccine and its potential cost savings Carga de morbilidad de la diarrea por rotavirus en Perú: la necesidad de una vacuna y su potencial de ahorro

    Directory of Open Access Journals (Sweden)

    Peter Ehrenkranz

    2001-10-01

    Full Text Available Objective. To assess the disease burden of rotavirus diarrhea in Peru as well the need for and the potential cost savings with a rotavirus vaccine in that country. Methods. To assess the burden of rotavirus diarrhea in Peru, we reviewed published and unpublished reports where rotavirus was sought as the etiologic agent of diarrhea in children. Rotavirus detection rates obtained from these studies were combined with diarrhea incidence rates from a number of national surveys in order to estimate both the burden of rotavirus diarrhea in the country and its associated medical costs. Results. Rotavirus is a significant cause of morbidity and mortality in Peruvian children. In their first 5 years of life, an estimated 1 in 1.6 children will experience an episode of rotavirus diarrhea, 1 in 9.4 will seek medical care, 1 in 19.7 will require hospitalization, and 1 in 375 will die of the disease. Per year, this represents approximately 384 000 cases, 64 000 clinic visits, 30 000 hospitalizations, and 1 600 deaths. The annual cost of medical care alone for these children is approximately US$ 2.6 million--and that does not take into account the indirect or societal costs of the illness and the deaths. Conclusions. Rotavirus immunization provides the prospect of decreasing the morbidity and mortality from diarrhea in Peru, but a vaccine regimen would have to be relatively inexpensive, a few dollars or less per child. Future cost-effectiveness analyses should explore the total costs (medical as well as indirect or societal associated with rotavirus diarrhea. Newly licensed vaccines should be tested according to both their ability to avert deaths and their efficacy with fewer than three doses. All three of these factors could increase the cost savings associated with a rotavirus vaccine.Objetivos. Evaluar la carga de morbilidad de la diarrea por rotavirus en Perú, la necesidad de una vacuna y el ahorro que esta podría proporcionar en este país. M

  18. Inferring Saving in Training Time From Effect Size Estimates

    National Research Council Canada - National Science Library

    Burright, Burke

    2000-01-01

    .... Students' time saving represents a major potential benefit of using them. This paper fills a methodology gap in estimating the students' timesaving benefit of asynchronous training technologies...

  19. Identification of potential regional sources of atmospheric total gaseous mercury in Windsor, Ontario, Canada using hybrid receptor modeling

    Directory of Open Access Journals (Sweden)

    X. Xu

    2010-08-01

    Full Text Available Windsor (Ontario, Canada experiences trans-boundary air pollution as it is located on the border immediately downwind of industrialized regions of the United States of America. A study was conducted in 2007 to identify the potential regional sources of total gaseous mercury (TGM and investigate the effects of regional sources and other factors on seasonal variability of TGM concentrations in Windsor.

    TGM concentration was measured at the University of Windsor campus using a Tekran® 2537A Hg vapour analyzer. An annual mean of 2.02±1.63 ng/m3 was observed in 2007. The average TGM concentration was high in the summer (2.48±2.68 ng/m3 and winter (2.17±2.01 ng/m3, compared to spring (1.88±0.78 ng/m3 and fall (1.76±0.58 ng/m3. Hybrid receptor modeling potential source contribution function (PSCF was used by incorporating 72-h backward trajectories and measurements of TGM in Windsor. The results of PSCF were analyzed in conjunction with the Hg emissions inventory of North America (by state/province to identify regions affecting Windsor. In addition to annual modeling, seasonal PSCF modeling was also conducted. The potential source region was identified between 24–61° N and 51–143° W. Annual PSCF modeling identified major sources southwest of Windsor, stretching from Ohio to Texas. The emissions inventory also supported the findings, as Hg emissions were high in those regions. Results of seasonal PSCF modeling were analyzed to find the combined effects of regional sources, meteorological conditions, and surface re-emissions, on seasonal variability of Hg concentrations. It was found that the summer and winter highs of atmospheric Hg can be attributed to areas where large numbers of coal fired power plants are located in the USA. Weak atmospheric dispersion due to low winds and high re-emission from surfaces due to higher temperatures also contributed to high concentrations in

  20. Measuring scarce water saving from interregional virtual water flows in China

    Science.gov (United States)

    Zhao, X.; Li, Y. P.; Yang, H.; Liu, W. F.; Tillotson, M. R.; Guan, D.; Yi, Y.; Wang, H.

    2018-05-01

    Trade of commodities can lead to virtual water flows between trading partners. When commodities flow from regions of high water productivity to regions of low water productivity, the trade has the potential to generate water saving. However, this accounting of water saving does not account for the water scarcity status in different regions. It could be that the water saving generated from this trade occurs at the expense of the intensified water scarcity in the exporting region, and exerts limited effect on water stress alleviation in importing regions. In this paper, we propose an approach to measure the scarce water saving associated with virtual water trade (measuring in water withdrawal/use). The scarce water is quantified by multiplying the water use in production with the water stress index (WSI). We assessed the scarce water saving/loss through interprovincial trade within China using a multi-region input-output table from 2010. The results show that interprovincial trade resulted in 14.2 km3 of water loss without considering water stress, but only 0.4 km3 scarce water loss using the scarce water concept. Among the 435 total connections of virtual water flows, 254 connections contributed to 20.2 km3 of scarce water saving. Most of these connections are virtual water flows from provinces with lower WSI to that with higher WSI. Conversely, 175 connections contributed to 20.6 km3 of scarce water loss. The virtual water flow connections between Xinjiang and other provinces stood out as the biggest contributors, accounting for 66% of total scarce water loss. The results show the importance of assessing water savings generated from trade with consideration of both water scarcity status and water productivity across regions. Identifying key connections of scarce water saving is useful in guiding interregional economic restructuring towards water stress alleviation, a major goal of China’s sustainable development strategy.

  1. Energy conservation potential in Taiwanese textile industry

    International Nuclear Information System (INIS)

    Hong, Gui-Bing; Su, Te-Li; Lee, Jenq-Daw; Hsu, Tsung-Chi; Chen, Hua-Wei

    2010-01-01

    Since Taiwan lacks sufficient self-produced energy, increasing energy efficiency and energy savings are essential aspects of Taiwan's energy policy. This work summarizes the energy savings implemented by 303 firms in Taiwan's textile industry from the on-line Energy Declaration System in 2008. It was found that the total implemented energy savings amounted to 46,074 ton of oil equivalent (TOE). The energy saving was equivalent to 94,614 MWh of electricity, 23,686 kl of fuel oil and 4887 ton of fuel coal. It represented a potential reduction of 143,669 ton in carbon dioxide emissions, equivalent to the annual carbon dioxide absorption capacity of a 3848 ha plantation forest. This study summarizes energy-saving measures for energy users and identifies the areas for making energy saving to provide an energy efficiency baseline.

  2. Sign Up for Savings.

    Science.gov (United States)

    Kennedy, Mike

    2002-01-01

    Discusses performance service contracts between educational facilities and energy services companies, in which the company provides the money for energy-efficiency improvements and the school pays the company an annual fee. The company guarantees the savings will meet or exceed the fee. (EV)

  3. Saving Malta's music memory

    OpenAIRE

    Sant, Toni

    2013-01-01

    Maltese music is being lost. Along with it Malta loses its culture, way of life, and memories. Dr Toni Sant is trying to change this trend through the Malta Music Memory Project (M3P) http://www.um.edu.mt/think/saving-maltas-music-memory-2/

  4. Save Our Water Resources.

    Science.gov (United States)

    Bromley, Albert W.

    The purpose of this booklet, developed as part of Project SOAR (Save Our American Resources), is to give Scout leaders some facts about the world's resources, the sources of water pollution, and how people can help in obtaining solutions. Among the topics discussed are the world's water resources, the water cycle, water quality, sources of water…

  5. Gun control saves lives

    African Journals Online (AJOL)

    gun control legislation. One study estimated that more than 4 500 lives were saved across five SA cities from 2001 to 2005.[5] Pro-gun interest groups seeking to promote gun ownership and diffusion have attacked these findings, suggesting that stricter gun control was only enacted in 2004 following the publication of ...

  6. A new corps of trained Grand-Aides has the potential to extend reach of primary care workforce and save money.

    Science.gov (United States)

    Garson, Arthur; Green, Donna M; Rodriguez, Lia; Beech, Richard; Nye, Christopher

    2012-05-01

    Because the Affordable Care Act will expand health insurance to cover an estimated thirty-two million additional people, new approaches are needed to expand the primary care workforce. One possible solution is Grand-Aides®, who are health care professionals operating under the direct supervision of nurses, and who are trained and equipped to conduct telephone consultations or make primary care home visits to patients who might otherwise be seen in emergency departments and clinics. We conducted pilot tests with Grand-Aides in two pediatric Medicaid settings: an urban federally qualified health center in Houston, Texas, and a semi-rural emergency department in Harrisonburg, Virginia. We estimated that Grand-Aides and their supervisors averted 62 percent of drop-in visits at the Houston clinic and would have eliminated 74 percent of emergency department visits at the Virginia test site. We calculated the cost of the Grand-Aides program to be $16.88 per encounter. That compares with current Medicaid payments of $200 per clinic visit in Houston and $175 per emergency department visit in Harrisonburg. In addition to reducing health care costs, Grand-Aides have the potential to make a substantial impact in reducing congestion in primary care practices and emergency departments.

  7. Breaking the ritual metabolic cycle in order to save acetyl CoA: A potential role for mitochondrial humanin in T2 bladder cancer aggressiveness

    Directory of Open Access Journals (Sweden)

    Nesreen Nabil Omar

    2017-06-01

    Full Text Available Introduction: Cancer cells may exhibit outsourcing of their high energy need in order to avoid the intrinsic mitochondrial apoptosis. Reduced mitochondrial respiration and accumulation of mitochondrial genome mutations are among metabolic transformations in this regard. Mitochondrial humanin (MT-RNR2 is a small peptide with anti-apoptotic activities attributed to binding some pro-apoptotic proteins. Aim of the work: The current study aims at investigating the expression of mitochondrial humanin in bladder tumor cells and the possible casting of humanin anti-apoptotic action through orchestrating some of the mitochondrial metabolic enzymes. Material and methods: Here messenger RNA of humanin, succinate dehydrogenase, glutaminase, isocitrate dehydrogenase were compared in tissues from patients with T2 bladder carcinoma in comparison to tumor associated normal tissues from the same patients. Levels of lactate and mitochondrial pyruvate carrier (MPC1 mRNA were determined to scrutinize the prevalence of aerobic glycolysis. Results: The present study found that tumor cells had suppressed aerobic glycolysis, augmented mitochondrial respiration and interrupted tricarboxylic acid cycle, all of which were suggested to serve tumor aggressiveness. MT-RNR2 was found closely related to the alterations in mitochondrial activity. Conclusion: MT-RNR2 plays its anti-apoptotic role partly by avoiding deploying energy from complete oxidation of organic compounds to inorganic wastes. Thus MT-RNR2 can potentially serve as a new biomarker in the diagnosis of bladder carcinoma especially that it is present in blood circulation.

  8. Refrigeration: Introducing energy saving opportunities for business

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2006-04-15

    In some industries, most notably food and drink and chemicals, refrigeration accounts for a significant proportion of overall site energy costs. For instance, in the industrial handling of meat, poultry and fish, it often accounts for 50% of total energy costs. In ice-cream production the proportion is 70%. In a number of commercial sectors, refrigeration also represents a significant proportion of overall energy costs. For example: Cold storage 90%; Food supermarkets 50%; Small shops with refrigerated cabinets 70% or over; Pubs and clubs 30%. Against these high costs, even a small reduction in refrigeration energy use can offer significant cost savings, resulting in increased profits. Energy saving need not be expensive. Energy savings of up to 20% can be realised in many refrigeration plant through actions that require little or no investment. In addition, improving the efficiency and reducing the load on a refrigeration plant can improve reliability and reduce the likelihood of a breakdown. Most organisations can save energy and money on refrigeration by: More efficient equipment; Good maintenance; Housekeeping and control. This publication provides an understanding of the operation of refrigeration systems, identifies where savings can be realised and will enable readers to present an informed case on energy savings to key decision makers within their organisation. (GB)

  9. Preliminary estimates of cost savings for defense high level waste vitrification options

    International Nuclear Information System (INIS)

    Merrill, R.A.; Chapman, C.C.

    1993-09-01

    The potential for realizing cost savings in the disposal of defense high-level waste through process and design modificatins has been considered. Proposed modifications range from simple changes in the canister design to development of an advanced melter capable of processing glass with a higher waste loading. Preliminary calculations estimate the total disposal cost (not including capital or operating costs) for defense high-level waste to be about $7.9 billion dollars for the reference conditions described in this paper, while projected savings resulting from the proposed process and design changes could reduce the disposal cost of defense high-level waste by up to $5.2 billion

  10. Save energy - for industry

    International Nuclear Information System (INIS)

    Anon.

    1983-01-01

    The article is an interview with Glenn Bjorklund, Vice President of SCalEd (Southern California Edison). The variations in Californian power demand and public electricity consumption habits are explained, together with types of power source used in electricity production. Questions are posed concerning SCalEd's energy saving strategy. The political implications of electricity charge changes are discussed. The planned energy resources for 1982-1992 are given with nuclear power being the largest contributor. (H.J.P./G.T.H.)

  11. Potential Rebates Saved by HHS Determinations

    Data.gov (United States)

    U.S. Department of Health & Human Services — These estimates are provided from 2010 data. Final amount of rebates will vary with market conditions and may be lower as insurance companies lower premiums for...

  12. 'Nurture the sprouting bud; do not uproot it'. Using saving groups to save for maternal and newborn health: lessons from rural Eastern Uganda.

    Science.gov (United States)

    Ekirapa-Kiracho, Elizabeth; Paina, Ligia; Muhumuza Kananura, Rornald; Mutebi, Aloysius; Jane, Pacuto; Tumuhairwe, Juliet; Tetui, Moses; Kiwanuka, Suzanne N

    2017-08-01

    Saving groups are increasingly being used to save in many developing countries. However, there is limited literature about how they can be exploited to improve maternal and newborn health. This paper describes saving practices, factors that encourage and constrain saving with saving groups, and lessons learnt while supporting communities to save through saving groups. This qualitative study was done in three districts in Eastern Uganda. Saving groups were identified and provided with support to enhance members' access to maternal and newborn health. Fifteen focus group discussions (FGDs) and 18 key informant interviews (KIIs) were conducted to elicit members' views about saving practices. Document review was undertaken to identify key lessons for supporting saving groups. Qualitative data are presented thematically. Awareness of the importance of saving, safe custody of money saved, flexible saving arrangements and easy access to loans for personal needs including transport during obstetric emergencies increased willingness to save with saving groups. Saving groups therefore provided a safety net for the poor during emergencies. Poor management of saving groups and detrimental economic practices like gambling constrained saving. Efficient running of saving groups requires that they have a clear management structure, which is legally registered with relevant authorities and that it is governed by a constitution. Saving groups were considered a useful form of saving that enabled easy acess to cash for birth preparedness and transportation during emergencies. They are like 'a sprouting bud that needs to be nurtured rather than uprooted', as they appear to have the potential to act as a safety net for poor communities that have no health insurance. Local governments should therefore strengthen the management capacity of saving groups so as to ensure their efficient running through partnerships with non-governmental organizations that can provide support to such groups.

  13. The value of retrofitting carbon-saving measures into fuel poor social housing

    International Nuclear Information System (INIS)

    Jenkins, D.P.

    2010-01-01

    With current fuel poverty and carbon-saving policies continuing to miss their targets in the UK, the synergy between the two problems is investigated to highlight an approach that could be mutually beneficial. Focussing on the 550,000 fuel poor socially housed dwellings in the UK, costs of between Pounds 3.9 and Pounds 17.5 bn are estimated as the required capital investment for achieving deep-cut carbon savings (defined as at least 50%) across this section of the housing stock, with a potential total annual carbon saving of 1.7 MtCO 2 . It is assumed that such costs would be largely (or totally) state-funded, though additional private investment could clearly increase the possible carbon savings across this section of the stock. The use of these socially housed fuel poor dwellings as low-carbon exemplars is discussed, and benefits for the private housing sector are postulated. The study also focuses on the problem of installing non-cost effective measures, i.e. technologies that would not currently be encouraged by existing subsidy schemes, but which might be necessary for achieving large carbon-saving targets.

  14. Do Medicaid home and community based service waivers save money?

    Science.gov (United States)

    Harrington, Charlene; Ng, Terence; Kitchener, Martin

    2011-10-01

    This article estimates the potential savings to the Medicaid program of using 1915c Home and Community Based Services (HCBS) waivers rather than institutional care. For Medicaid HCBS waiver expenditures of $25 billion in 2006, we estimate the national savings to be over $57 billion, or $57,338 per waiver participant in 2006 compared with the cost of Medicaid institutional care (for which all waiver participants are eligible). When taking into account a potential 50% "woodwork effect" (for people who might have refused institutional services), the saving would be $21 billion. This analysis demonstrates that HCBS waiver programs present significant direct financial savings to Medicaid long-term care (LTC) programs.

  15. Technical energy savings versus changes in human behaviour

    DEFF Research Database (Denmark)

    Nørgaard, Jørgen

    1996-01-01

    Energy savings seems to be the most environmentally benign element in an energy policy. The paper is a reflection on the work on saving energy both by improving technology and by adapting human daily behaviour. A simple model is suggested for the energy chain which converts the primary energy all...... the way into human satisfaction via energy services. Results of various analyses and field experiments show saving potentials for electricity of 50 - 80 per cents. Barriers for implementing these technical saving options are discussed. Also the necessity and potentials for changing behavioural or life...

  16. Entrepreneurial Saving Practices and Reinvestment

    NARCIS (Netherlands)

    Beck, Thorsten; Pamuk, Haki; Uras, Burak R.

    2017-01-01

    We use a novel enterprise survey to gauge the relationship between saving instruments and entrepreneurial reinvestment. We show that while most informal saving practices are not associated with a lower likelihood of reinvestment when compared with formal saving practices, there is a significantly

  17. Social Capital and Savings Behavior

    DEFF Research Database (Denmark)

    Newman, Carol; Tarp, Finn; Khai, Luu Duc

    In this paper, we analyze household savings in rural Vietnam paying particular attention to the factors that determine the proportion of savings held as formal deposits. Our aim is to explore the extent to which social capital can play a role in promoting formal savings behavior. Social capital...

  18. Saving water through global trade

    NARCIS (Netherlands)

    Chapagain, Ashok; Hoekstra, Arjen Ysbert; Savenije, H.H.G.

    2005-01-01

    Many nations save domestic water resources by importing water-intensive products and exporting commodities that are less water intensive. National water saving through the import of a product can imply saving water at a global level if the flow is from sites with high to sites with low water

  19. Potential Impact of Rainfall on the Air-Surface Exchange of Total Gaseous Mercury from Two Common Urban Ground Surfaces

    Science.gov (United States)

    The impact of rainfall on total gaseous mercury (TGM) flux from pavement and street dirt surfaces was investigated in an effort to determine the influence of wet weather events on mercury transport in urban watersheds. Street dirt and pavement are common urban ground surfaces tha...

  20. Energy. Saving 'Private' Areva

    International Nuclear Information System (INIS)

    Dupin, Ludovic

    2015-01-01

    While Areva keeps on loosing money (billions of euros for 2014), the saving of this company is at stake. Staff is already planned to be reduced in La Hague, and other staff reductions might occur after the failure of a previous strategic plan. Various activities could be sold (dismantling, mining). The article outlines the difficult relationships between Areva and EDF and the problems also faced by EDF. Some actors think that Areva should remain independent from EDF in order to be free to compete on international bidding. The rapprochement between these two companies is said to be necessary for the Ministry but seems very difficult to achieve

  1. Water Saving for Development

    Science.gov (United States)

    Zacharias, Ierotheos

    2013-04-01

    The project "Water Saving for Development (WaS4D)" is financed by European Territorial Cooperational Programme, Greece-Italy 2007-2013, and aims at developing issues on water saving related to improvement of individual behaviors and implementing innovative actions and facilities in order to harmonize policies and start concrete actions for a sustainable water management, making also people and stakeholders awake to water as a vital resource, strategic for quality of life and territory competitiveness. Drinkable water saving culture & behavior, limited water resources, water supply optimization, water resources and demand management, water e-service & educational e-tools are the key words of WaS4D. In this frame the project objectives are: • Definition of water need for domestic and other than domestic purposes: regional and territorial hydro-balance; • promotion of locally available resources not currently being used - water recycling or reuse and rainwater harvesting; • scientific data implementation into Informative Territorial System and publication of geo-referred maps into the institutional web sites, to share information for water protection; • participated review of the regulatory framework for the promotion of water-efficient devices and practices by means of the definition of Action Plans, with defined targets up to brief (2015) and medium (2020) term; • building up water e-services, front-office for all the water issues in building agricultural, industrial and touristic sectors, to share information, procedures and instruments for the water management; • creation and publication of a user friendly software, a game, to promote sustainability for houses also addressed to young people; • creation of water info point into physical spaces called "Water House" to promote education, training, events and new advisory services to assist professionals involved in water uses and consumers; • implementation of participatory approach & networking for a

  2. Savings for the Poor

    OpenAIRE

    Ignacio Mas

    2010-01-01

    This paper reviews the relevance of formal financial services – in particular, savings – to poor people, the economic factors that have hindered the mass-scale delivery of such services in developing countries, and the technology-based opportunities that exist today to make massive gains in financial inclusion. It also highlights the benefits to government from universal financial access, as well as the key policy enablers that would need to be put in place to allow the necessary innovati...

  3. Locomotive energy savings possibilities

    Directory of Open Access Journals (Sweden)

    Leonas Povilas LINGAITIS

    2009-01-01

    Full Text Available Economic indicators of electrodynamic braking have not been properly estimated. Vehicles with alternative power trains are transitional stage between development of pollution- free vehicles. According to these aspects the investigation on conventional hybrids drives and their control system is carried out in the article. The equation that allows evaluating effectiveness of regenerative braking for different variants of hybrid drive are given. Presenting different types of locomotive energy savings power systems, which are using regenerative braking energy any form of hybrid traction vehicles systems, circuit diagrams, electrical parameters curves.

  4. Estimated saving potential and efficient use of energy in air conditioning by means of the solar protection; Potencial estimado de ahorro y uso eficiente de energia en aires acondicionados mediante la proteccion solar

    Energy Technology Data Exchange (ETDEWEB)

    Mejia D, David; Morillon G, David; Rodriguez V, Luis [Universidad Nacional Autonoma de Mexico, Mexico, D.F. (Mexico)

    2001-07-01

    In here it is presented the analysis of the impact of the solar gains through the transparent parts of a prototype house of social interest, located in a dry warm climate. This analysis was made to determine the gains through windows for the summer time and under the following conditions: without outside solar protections, with the use of eaves, solar breakers and finally with the use of both systems of solar protection. The results were compared to obtain the considered potential of energy saving in cooling equipment, that could be obtained in future houses to build. [Spanish] Se presenta el analisis del impacto de las ganancias solares a traves de las partes transparentes de un prototipo de vivienda de interes social, ubicado en un clima calido seco. Dicho analisis se realizo para determinar las ganancias a traves de ventanas para la epoca de verano y bajo las siguientes condiciones: sin protecciones solares exteriores, con el empleo de aleros, con quiebrasoles y finalmente con el empleo de ambos sistemas de proteccion solar. Se compararon los resultados para obtener el potencial estimado de ahorro de energia en equipo de enfriamiento, que se tendria en las futuras viviendas por construir.

  5. Diamond-set drill bits: savings achieved at Cominak

    International Nuclear Information System (INIS)

    Artru, P.; Bibert, F.X.; Croisat, G.

    1988-01-01

    Rotary instead of percussion adoption of drilling in the underground Akouta mine (Niger) has been the cause of important savings in blasting and bolting operations. Other savings affect capital expenditures and indirect savings are coming from better working conditions. For blast holes drilling and bolting, spare parts expenditures are 2.4 times lower with rotary drilling. Drilling rods are cheaper and last longer with rotary drilling. A rotary equipped Jumbos fleet is cheaper to maintain and is 18% more available, due to less mechanical and other breakdowns. Total savings for the mine owner and operator Cominak reach more than a billion of CFA francs [fr

  6. What are the cost savings associated with providing access to specialist care through the Champlain BASE eConsult service? A costing evaluation.

    Science.gov (United States)

    Liddy, Clare; Drosinis, Paul; Deri Armstrong, Catherine; McKellips, Fanny; Afkham, Amir; Keely, Erin

    2016-06-23

    This study estimates the costs and potential savings associated with all eConsult cases completed between 1 April 2014 and 31 March 2015. Costing evaluation from the societal perspective estimating the costs and potential savings associated with all eConsults completed during the study period. Champlain health region in Eastern Ontario, Canada. Primary care providers and specialists registered to use the eConsult service. Costs included (1) delivery costs; (2) specialist remuneration; (3) costs associated with traditional (face-to-face) referrals initiated as a result of eConsult. Potential savings included (1) costs of traditional referrals avoided; (2) indirect patient savings through avoided travel and lost wages/productivity. Net potential societal cost savings were estimated by subtracting total costs from total potential savings. A total of 3487 eConsults were completed during the study period. In 40% of eConsults, a face-to-face specialist visit was originally contemplated but avoided as result of eConsult. In 3% of eConsults, a face-to-face specialist visit was not originally contemplated but was prompted as a result of the eConsult. From the societal perspective, total costs were estimated at $207 787 and total potential savings were $246 516. eConsult led to a net societal saving of $38 729 or $11 per eConsult. Our findings demonstrate potential cost savings from the societal perspective, as patients avoided the travel costs and lost wages/productivity associated with face-to-face specialist visits. Greater savings are expected once we account for other costs such as avoided tests and visits and potential improved health outcomes associated with shorter wait times. Our findings are valuable for healthcare delivery decision-makers as they seek solutions to improve care in a patient-centred and efficient manner. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  7. Energy Savings from Industrial Water Reductions

    Energy Technology Data Exchange (ETDEWEB)

    Rao, Prakash; McKane, Aimee; de Fontaine, Andre

    2015-08-03

    Although it is widely recognized that reducing freshwater consumption is of critical importance, generating interest in industrial water reduction programs can be hindered for a variety of reasons. These include the low cost of water, greater focus on water use in other sectors such as the agriculture and residential sectors, high levels of unbilled and/or unregulated self-supplied water use in industry, and lack of water metering and tracking capabilities at industrial facilities. However, there are many additional components to the resource savings associated with reducing site water use beyond the water savings alone, such as reductions in energy consumption, greenhouse gas emissions, treatment chemicals, and impact on the local watershed. Understanding and quantifying these additional resource savings can expand the community of businesses, NGOs, government agencies, and researchers with a vested interest in water reduction. This paper will develop a methodology for evaluating the embedded energy consumption associated with water use at an industrial facility. The methodology developed will use available data and references to evaluate the energy consumption associated with water supply and wastewater treatment outside of a facility’s fence line for various water sources. It will also include a framework for evaluating the energy consumption associated with water use within a facility’s fence line. The methodology will develop a more complete picture of the total resource savings associated with water reduction efforts and allow industrial water reduction programs to assess the energy and CO2 savings associated with their efforts.

  8. FORTRAN 4 programs for the extraction of potential well parameters from the energy dependence of total elastic scattering cross sections

    Science.gov (United States)

    Labudde, R. A.

    1972-01-01

    An attempt has been made to keep the programs as subroutine oriented as possible. Usually only the main programs are directly concerned with the problem of total cross sections. In particular the subroutines POLFIT, BILINR, GASS59/MAXLIK, SYMOR, MATIN, STUDNT, DNTERP, DIFTAB, FORDIF, EPSALG, REGFAL and ADSIMP are completely general, and are concerned only with the problems of numerical analysis and statistics. Each subroutine is independently documented.

  9. Appraisal of Total Phenol, Flavonoid Contents, and Antioxidant Potential of Folkloric Lannea coromandelica Using In Vitro and In Vivo Assays

    Directory of Open Access Journals (Sweden)

    Tekeshwar Kumar

    2015-01-01

    Full Text Available The aim of this study was to determine the impending antioxidant properties of different extracts of crude methanolic extract (CME of leaves of Lannea coromandelica (L. coromandelica and its two ethyl acetate (EAF and aqueous (AqF subfractions by employing various established in vitro systems and estimation of total phenolic and flavonoid content. The results showed that extract and fractions possessed strong antioxidant activity in vitro and among them, EAF had the strongest antioxidant activity. EAF was confirmed for its highest phenolic content, total flavonoid contents, and total antioxidant capacity. The EAF was found to show remarkable scavenging activity on 2,2-diphenylpicrylhydrazyl (DPPH (EC50 63.9 ± 0.64 µg/mL, superoxide radical (EC50 8.2 ± 0.12 mg/mL, and Fe2+ chelating activity (EC50 6.2 ± 0.09 mg/mL. Based on our in vitro results, EAF was investigated for in vivo antioxidant assay. Intragastric administration of the EAF can significantly increase levels of superoxide dismutase (SOD, catalase (CAT, glutathione (GSH, and glutathione peroxidase (GSH-Px levels, and decrease malondialdehyde (MDA content in the liver and kidney of CCl4-intoxicated rats. These new evidences show that L. coromandelica bared antioxidant activity.

  10. Savings in its sights for Somerset Trust.

    Science.gov (United States)

    Russell, Colin

    2011-10-01

    Colin Russell, healthcare specialist at Schneider Electric (pictured), explains how the company has recently worked with Taunton and Somerset NHS Foundation Trust to implement a major energy-saving project at the Trust's Musgrove Park Hospital in Taunton. He argues that, at a time when all areas of the service are being asked to reduce costs, such partnerships can potentially save the institution millions of pounds and significantly reduce carbon emissions, while "revitalising" parts of the NHS estate, and ensuring continuity of vital hospital services for facilities managers.

  11. Financing aspects of electricity saving's in Brazil

    International Nuclear Information System (INIS)

    Pacca, S.A.; Sauer, I.L.

    1996-01-01

    Programs regarding to energy saving in Brasil arised by the early 80's from the concern with oil products consumption. The situation has changed and electricity is growing in importance when energy conservation is discussed. Thus, the government, following examples from abroad, has been trying to overcome the barriers that obstruct a massive process evolution towards energy saving, since the potential is spread out in many society segments. One important issue is related to financing energy conservation. This paper attempts to analyze the utilities efforts allied to public and private banks investments towards energy conservation financing. (author)

  12. Active vs. Passive Decisions and Crowdout in Retirement Savings Accounts: Evidence from Denmark

    DEFF Research Database (Denmark)

    Nielsen, Torben Heien; Leth-Petersen, Søren; Chetty, Raj

    2012-01-01

    Do retirement savings policies – such as tax subsidies or employer-provided pension plans – increase total saving for retirement or simply induce shifting across accounts? We revisit this classic question using 45 million observations on savings for the population of Denmark. We find that a policy......'s impact on total savings depends critically on whether it changes savings rates by active or passive choice. Tax subsidies, which rely upon individuals to take an action to raise savings, have small impacts on total wealth. We estimate that each $1 of tax expenditure on subsidies increases total saving...... by 1 cent. In contrast, policies that raise savings automatically even if individuals take no action – such as employer-provided pensions or automatic contributions to retirement accounts – increase wealth accumulation substantially. Price subsidies only affect the behavior of active savers who respond...

  13. Total system performance predictions (TSPA-1995) for the potential high-level waste repository at Yucca Mountain

    International Nuclear Information System (INIS)

    Sevougian, S.D.; Andrews, R.W.; McNeish, J.A.

    1996-01-01

    The management and operating contractor for the potential high-level nuclear waste repository at Yucca Mountain, Nevada, has been recently completed a new performance assessment of the ability of the repository to isolate and contain nuclear waste for long time periods (up to 1,000,000 years). Sensitivity analyses determine the most important physical parameters and processes, using the most current information and models

  14. Options for Department of Defense Total Workforce Supply and Demand Analysis: Potential Approaches and Available Data Sources

    Science.gov (United States)

    2014-01-01

    publications do not necessarily reflect the opinions of its research clients and sponsors. Support RAND Make a tax-deductible charitable contribution at...in Workforce Planning and Potential Modeling of Military Training, Land Defense Science and Technology Organisation , Australian Government Department...Technology Organisation , Australian Government Department of Defense, DSTO-TR-2037, 2007. Ward, D., “Workforce Demand Forecasting Techniques,” Human

  15. A budget impact analysis of Spiromax® compared with Turbuhaler® for the treatment of moderate to severe asthma: a potential improvement in the inhalation technique to strengthen medication adherence could represent savings for the Spanish Healthcare System and five Spanish regions

    Directory of Open Access Journals (Sweden)

    Darbà J

    2016-09-01

    , Catalonia, Galicia, Madrid, and Valencia, respectively. Based on the forecast uptake of DuoResp® Spiromax®, the total budget savings in Spain were expected to be €1.509 million over the next 4 years. Region-specific rates imply that the total savings were expected to be €229,706 in Andalusia, €90,145 in Catalonia, €188,327 in Galicia, €122,669 in Madrid, and €165,796 in Valencia over 2015–2018.Conclusion: The introduction of DuoResp® Spiromax®, which represents a potential improvement in the inhalation technique to strengthen medication adherence for the treatment of moderate to severe asthma, could represent savings for the Spanish National Health Society and five Spanish regions. Keywords: dry powder inhaler, economic evaluation, region-specific estimates, payers perspective

  16. Reported Energy and Cost Savings from the DOE ESPC Program: FY 2014

    Energy Technology Data Exchange (ETDEWEB)

    Slattery, Bob S. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2015-03-01

    The objective of this work was to determine the realization rate of energy and cost savings from the Department of Energy’s Energy Savings Performance Contract (ESPC) program based on information reported by the energy services companies (ESCOs) that are carrying out ESPC projects at federal sites. Information was extracted from 156 Measurement and Verification (M&V) reports to determine reported, estimated, and guaranteed cost savings and reported and estimated energy savings for the previous contract year. Because the quality of the reports varied, it was not possible to determine all of these parameters for each project. For all 156 projects, there was sufficient information to compare estimated, reported, and guaranteed cost savings. For this group, the total estimated cost savings for the reporting periods addressed were $210.6 million, total reported cost savings were $215.1 million, and total guaranteed cost savings were $204.5 million. This means that on average: ESPC contractors guaranteed 97% of the estimated cost savings; projects reported achieving 102% of the estimated cost savings; and projects reported achieving 105% of the guaranteed cost savings. For 155 of the projects examined, there was sufficient information to compare estimated and reported energy savings. On the basis of site energy, estimated savings for those projects for the previous year totaled 11.938 million MMBtu, and reported savings were 12.138 million MMBtu, 101.7% of the estimated energy savings. On the basis of source energy, total estimated energy savings for the 155 projects were 19.052 million MMBtu, and reported saving were 19.516 million MMBtu, 102.4% of the estimated energy savings.

  17. Does Daylight Saving Save Energy? A Meta-Analysis

    OpenAIRE

    Havránek, Tomáš; Herman, Dominik; Irsova, Zuzana

    2016-01-01

    The original rationale for adopting daylight saving time (DST) was energy savings. Modern research studies, however, question the magnitude and even direction of the effect of DST on energy consumption. Representing the first meta-analysis in this literature, we collect 162 estimates from 44 studies and find that the mean reported estimate indicates modest energy savings: 0.34% during the days when DST applies. The literature is not affected by publication bias, but the results vary systemati...

  18. Savings impact of a corporate energy manager

    International Nuclear Information System (INIS)

    Sikorski, B.D.; O'Donnell, B.A.

    1999-01-01

    This paper discusses the cost savings impact of employing an energy manager with a 16,000-employee corporation. The corporation, Canada's second largest airline, is currently operating nearly 3,000,000 ft 2 of mixed-use facilities spread across the country, with an annual energy budget for ground facilities of over Cdn $4,000,000. This paper outlines the methodology used by the energy manager to deploy an energy management program over a two-year period between April 1995 and May 1997. The paper examines the successes and the lessons learned during the period and summarizes the costs and benefits of the program. The energy manager position was responsible for developing an energy history database with more than 100 active accounts and for monitoring and verifying energy savings. The energy manager implemented many relatively low-cost energy conservation measures, as well as some capital projects, during the first two years of the program. In total, these measures provided energy cost savings of $210,000 per year, or 5% of the total budget. In each case, technologies installed as part of the energy retrofit projects provided not only cost savings but also better control, reduced maintenance, and improved working conditions for employees

  19. Can lean save lives?

    Science.gov (United States)

    Fillingham, David

    2007-01-01

    The purpose of this paper is to show how over the last 18 months Bolton Hospitals NHS Trust have been exploring whether or not lean methodologies, often known as the Toyota Production System, can indeed be applied to healthcare. This paper is a viewpoint. One's early experience is that lean really can save lives. The Toyota Production System is an amazingly successful way of manufacturing cars. It cannot be simply translated unthinkingly into a hospital but lessons can be learned from it and the method can be adapted and developed so that it becomes owned by healthcare staff and focused towards the goal of improved patient care. Working in healthcare is a stressful and difficult thing. Everyone needs a touch of inspiration and encouragement. Applying lean to healthcare in Bolton seems to be achieving just that for those who work there.

  20. Total neutron-counting plutonium inventory measurement systems (PIMS) and their potential application to near real time materials accountancy (NRTMA)

    International Nuclear Information System (INIS)

    Driscall, I.; Fox, G.H.; Orr, C.H.; Whitehouse, K.R.

    1988-01-01

    A radiometric method of determining the inventory of an operating plutonium plant is described. An array of total neutron counters distributed across the plant is used to estimate hold-up at each plant item. Corrections for the sensitivity of detectors to plutonium in adjacent plant items are achieved through a matrix approach. This paper describes our experience in design, calibration and operation of a Plutonium Inventory Measurement System (PIMS) on an oxalate precipitation plutonium finishing line. Data from a recent trial of Near-Real-Time Materials Accounting (NRTMA) using the PIMS are presented and used to illustrate its present performance and problem areas. The reader is asked to consider what role PIMS might have in future accountancy systems

  1. What actions in the domain of energy saving?

    International Nuclear Information System (INIS)

    Gourlia, J.P.; Richard, P.

    2007-01-01

    The energy saving potentialities are very often put forward to justify actions of mastery of energy demand. What are the possible substitutes and their result in terms of energy saving? What are the tools implemented and the services proposed by energy suppliers to end-users? What is the optimum mix between the regulatory measures and the market instruments to perform energy saving? What are the costs generated by such measures with respect to the expected results? How to sensibilize citizens to energy saving actions? These questions were debated during a round table which gathered 4 participants and two chairmen. (J.S.)

  2. Can health promotion programs save Medicare money?

    Science.gov (United States)

    Goetzel, Ron Z; Shechter, David; Ozminkowski, Ronald J; Stapleton, David C; Lapin, Pauline J; McGinnis, J Michael; Gordon, Catherine R; Breslow, Lester

    2007-01-01

    The impact of an aging population on escalating US healthcare costs is influenced largely by the prevalence of chronic disease in this population. Consequently, preventing or postponing disease onset among the elderly has become a crucial public health issue. Fortunately, much of the total burden of disease is attributable to conditions that are preventable. In this paper, we address whether well-designed health promotion programs can prevent illness, reduce disability, and improve the quality of life. Furthermore, we assess evidence that these programs have the potential to reduce healthcare utilization and related expenditures for the Medicare program. We hypothesize that seniors who reduce their modifiable health risks can forestall disability, reduce healthcare utilization, and save Medicare money. We end with a discussion of a new Senior Risk Reduction Demonstration, which will be initiated by the Centers for Medicare and Medicaid Services in 2007, to test whether risk reduction programs developed in the private sector can achieve health improvements among seniors and a positive return on investment for the Medicare program. PMID:18044084

  3. REMINDER Saved Leave Scheme (SLS) : Transfer of leave to saved leave accounts

    CERN Multimedia

    HR Division

    2002-01-01

    Under the provisions of the voluntary saved leave scheme (SLS), a maximum total of 10 days'*) annual and compensatory leave (excluding saved leave accumulated in accordance with the provisions of Administrative Circular No. 22B) can be transferred to the saved leave account at the end of the leave year (30 September). We remind you that, since last year, unused leave of all those taking part in the saved leave scheme at the closure of the leave-year accounts is transferred automatically to the saved leave account on that date. Therefore, staff members have no administrative steps to take. In addition, the transfer, which eliminates the risk of omitting to request leave transfers and rules out calculation errors in transfer requests, will be clearly shown in the list of leave transactions that can be consulted in EDH from October 2002 onwards. Furthermore, this automatic leave transfer optimizes staff members' chances of benefiting from a saved leave bonus provided that they are still participants in the schem...

  4. Saved Leave Scheme (SLS) : Simplified procedure for the transfer of leave to saved leave accounts

    CERN Multimedia

    HR Division

    2001-01-01

    As part of the process of streamlining procedures, the HR and AS Divisions have jointly developed a system whereby annual and compensatory leave will henceforth be automatically transferred1) to saved leave accounts. Under the provisions of the voluntary saved leave scheme (SLS), a maximum total of 10 days'2) annual and compensatory leave (excluding saved leave accumulated in accordance with the provisions of Administrative Circular No. 22 B) can be transferred to the saved leave account at the end of the leave year (30 September). Previously, every person taking part in the scheme has been individually issued with a form for the purposes of requesting the transfer of leave to the leave account and the transfer has then had to be done manually by HR Division. To streamline the procedure, unused leave of all those taking part in the saved leave scheme at the closure of of the leave-year accounts will henceforth be transferred automatically to the saved leave account on that date. This simplification is in the ...

  5. Planning a Sabbatical? These Tips Can Save Taxes.

    Science.gov (United States)

    Matoney, Joseph P., Jr.; Weston, Marilyn

    1985-01-01

    Information on potential tax-saving opportunities when planning a sabbatical is provided for college personnel. Advice is offered about tax savings for: rental of the academician's personal residences while away from home, the home office deduction, use of an auto, and foreign income tax exclusion. The answer to what expenses are deductible…

  6. Using dew points to estimate savings during a planned cooling shutdown

    Science.gov (United States)

    Friedlein, Matthew T.; Changnon, David; Musselman, Eric; Zielinski, Jeff

    2005-12-01

    In an effort to save money during the summer of 2003, Northern Illinois University (NIU) administrators instituted a four-day working week and stopped air conditioning buildings for the three-day weekends (Friday through Sunday). Shutting down the air conditioning systems caused a noticeable drop in electricity usage for that part of the campus that features in our study, with estimated total electricity savings of 1,268,492 kilowatt-hours or 17% of the average usage during that eight-week period. NIU's air conditioning systems, which relied on evaporative cooling to function, were sensitive to dew point levels. Greatest savings during the shutdown period occurred on days with higher dew points. An examination of the regional dew point climatology (1959 2003) indicated that the average summer daily dew point for 2003 was 14.9°C (58.8°F), which fell in the lowest 20% of the distribution. Based on the relationship between daily average dew points and electrical usage, a predictive model that could estimate electrical daily savings was created. This model suggests that electrical savings related to any future three-day shutdowns over summer could be much greater in more humid summers. Studies like this demonstrate the potential value of applying climatological information and of integrating this information into practical decision-making.

  7. Total Reducing Capacity in Aquifer Minerals and Sediments: Quantifying the Potential to Attenuate Cr(VI) in Groundwater

    International Nuclear Information System (INIS)

    Sisman, S. Lara

    2015-01-01

    Hexavalent chromium, Cr(VI), is present in the environment as a byproduct of industrial processes. Due to its mobility and toxicity, it is crucial to attenuate or remove Cr(VI) from the environment. The objective of this investigation was to quantify potential natural attenuation, or reduction capacity, of reactive minerals and aquifer sediments. Samples of reduced-iron containing minerals such as ilmenite, as well as Puye Formation sediments representing a contaminated aquifer in New Mexico, were reacted with chromate. The change in Cr(VI) during the reaction was used to calculate reduction capacity. This study found that minerals that contain reduced iron, such as ilmenite, have high reducing capacities. The data indicated that sample history may impact reduction capacity tests due to surface passivation. Further, this investigation identified areas for future research including: a) refining the relationships between iron content, magnetic susceptibility and reduction capacity, and b) long term kinetic testing using fresh aquifer sediments.

  8. Total Reducing Capacity in Aquifer Minerals and Sediments: Quantifying the Potential to Attenuate Cr(VI) in Groundwater

    Energy Technology Data Exchange (ETDEWEB)

    Sisman, S. Lara [Univ. of Virginia, Charlottesville, VA (United States); Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2015-07-20

    Hexavalent chromium, Cr(VI), is present in the environment as a byproduct of industrial processes. Due to its mobility and toxicity, it is crucial to attenuate or remove Cr(VI) from the environment. The objective of this investigation was to quantify potential natural attenuation, or reduction capacity, of reactive minerals and aquifer sediments. Samples of reduced-iron containing minerals such as ilmenite, as well as Puye Formation sediments representing a contaminated aquifer in New Mexico, were reacted with chromate. The change in Cr(VI) during the reaction was used to calculate reduction capacity. This study found that minerals that contain reduced iron, such as ilmenite, have high reducing capacities. The data indicated that sample history may impact reduction capacity tests due to surface passivation. Further, this investigation identified areas for future research including: a) refining the relationships between iron content, magnetic susceptibility and reduction capacity, and b) long term kinetic testing using fresh aquifer sediments.

  9. Cost Savings of Nuclear Power with Total Fuel Reprocessing

    International Nuclear Information System (INIS)

    Solbrig, Charles W.; Benedict, Robert W.

    2006-01-01

    The cost of fast reactor (FR) generated electricity with pyro-processing is estimated in this article. It compares favorably with other forms of energy and is shown to be less than that produced by light water reactors (LWR's). FR's use all the energy in natural uranium whereas LWR's utilize only 0.7% of it. Because of high radioactivity, pyro-processing is not open to weapon material diversion. This technology is ready now. Nuclear power has the same advantage as coal power in that it is not dependent upon a scarce foreign fuel and has the significant additional advantage of not contributing to global warming or air pollution. A jump start on new nuclear plants could rapidly allow electric furnaces to replace home heating oil furnaces and utilize high capacity batteries for hybrid automobiles: both would reduce US reliance on oil. If these were fast reactors fueled by reprocessed fuel, the spent fuel storage problem could also be solved. Costs are derived from assumptions on the LWR's and FR's five cost components: 1) Capital costs: LWR plants cost $106/MWe. FR's cost 25% more. Forty year amortization is used. 2) The annual O and M costs for both plants are 9% of the Capital Costs. 3) LWR fuel costs about 0.0035 $/kWh. Producing FR fuel from spent fuel by pyro-processing must be done in highly shielded hot cells which is costly. However, the five foot thick concrete walls have the advantage of prohibiting diversion. LWR spent fuel must be used as feedstock for the FR initial core load and first two reloads so this FR fuel costs more than LWR fuel. FR fuel costs much less for subsequent core reloads ( 6 /MWe. The annual cost for a 40 year licensed plant would be 2.5 % of this or less if interest is taken into account. All plants will eventually have to replace those components which become radiation damaged. FR's should be designed to replace parts rather than decommission. The LWR costs are estimated to be 2.65 cents/kWh. FR costs are 2.99 cents/kWh for the first 7.5 years and 2.39 cents/kWh for the next 32.5 years. The average cost over forty years is 2.50 cents/kWh which is less than the LWR costs. These power costs are similar to coal power, are lower than gas, oil, and much lower than renewable power.(authors)

  10. Ecotoxicoparasitology of the gastrointestinal tracts of pinnipeds: the effect of parasites on the potential bioavailability of total mercury (THg).

    Science.gov (United States)

    McGrew, Ashley K; O'Hara, Todd M; Stricker, Craig A; Salman, Mo D; Van Bonn, William; Gulland, Frances M D; Whiting, Alex; Ballweber, Lora R

    2018-08-01

    Acanthocephalans, cestodes, and some species of nematodes acquire nutrients from the lumen contents in the gastrointestinal (GI) tract of their definitive host. These parasites are exposed to toxicants, such as mercury (Hg), through passive or active feeding mechanisms; therefore, the focus of this study was to determine if there is an effect of parasites on the dietary availability of total mercury (THg) within piscivorous pinniped hosts. THg concentrations ([THg]) in selected host tissues, parasites, and GI lumen contents from 22 California sea lions (Zalophus californianus), 15 ringed seals (Phoca hispida), and 4 spotted seals (Phoca largha) were determined. Among all pinnipeds, [THg] in acanthocephalans of the large intestine were significantly higher than concentrations in other samples (host lumen contents, other parasites and host intestinal wall), irrespective of location within the host GI tract. δ 15 N values of parasites depended both on parasite group and location within the GI tract. δ 15 N values were consistently higher in parasites inhabiting the large intestine, compared to elsewhere in the GI tract, for both sea lions and seals. δ 13 C values in parasites did not differ significantly from host GI tissues. Based on both [THg] and stable isotope values, parasites are likely affecting the Hg bioavailability within the GI lumen contents and host tissues, and toxicant-parasite interactions appear to depend on both parasitic taxon as well as their location within the host intestine. Copyright © 2018. Published by Elsevier B.V.

  11. 12 CFR 583.21 - Savings association.

    Science.gov (United States)

    2010-01-01

    ... AFFECTING SAVINGS AND LOAN HOLDING COMPANIES § 583.21 Savings association. The term savings association means a Federal savings and loan association or a Federal savings bank chartered under section 5 of the Home Owners' Loan Act, a building and loan, savings and loan or homestead association or a cooperative...

  12. Reinforcement Learning and Savings Behavior.

    Science.gov (United States)

    Choi, James J; Laibson, David; Madrian, Brigitte C; Metrick, Andrew

    2009-12-01

    We show that individual investors over-extrapolate from their personal experience when making savings decisions. Investors who experience particularly rewarding outcomes from saving in their 401(k)-a high average and/or low variance return-increase their 401(k) savings rate more than investors who have less rewarding experiences with saving. This finding is not driven by aggregate time-series shocks, income effects, rational learning about investing skill, investor fixed effects, or time-varying investor-level heterogeneity that is correlated with portfolio allocations to stock, bond, and cash asset classes. We discuss implications for the equity premium puzzle and interventions aimed at improving household financial outcomes.

  13. Calculation of the total potential between two deformed heavy ion nuclei using the Monte Carlo method and M3Y nucleon-nucleon forces

    International Nuclear Information System (INIS)

    Ghodsi, O. N.; Zanganeh, V.

    2009-01-01

    In the current study, a simulation technique has been employed to calculate the total potential between two deformed nuclei. It has been shown that this simulation technique is an efficient one for calculating the total potential for all possible orientations between the symmetry axes of the interacting nuclei using the realistic nuclear matter density and the M3Y nucleon-nucleon effective forces. The analysis of the results obtained for the 48 Ca+ 238 U, 46 Ti+ 46 Ti, and 27 Al+ 70 Ge reactions reveal that considering the density dependent effects in the M3Y forces causes the nuclear potential to drop by an amount of 0.4 MeV.

  14. Accurate and reliable quantification of total microalgal fuel potential as fatty acid methyl esters by in situ transesterification

    Energy Technology Data Exchange (ETDEWEB)

    Laurens, Lieve M.L.; Quinn, Matthew; Wychen, Stefanie van; Templeton, David W.; Wolfrum, Edward J. [National Bioenergy Center, National Renewable Energy Laboratory, Golden, CO (United States)

    2012-04-15

    In the context of algal biofuels, lipids, or better aliphatic chains of the fatty acids, are perhaps the most important constituents of algal biomass. Accurate quantification of lipids and their respective fuel yield is crucial for comparison of algal strains and growth conditions and for process monitoring. As an alternative to traditional solvent-based lipid extraction procedures, we have developed a robust whole-biomass in situ transesterification procedure for quantification of algal lipids (as fatty acid methyl esters, FAMEs) that (a) can be carried out on a small scale (using 4-7 mg of biomass), (b) is applicable to a range of different species, (c) consists of a single-step reaction, (d) is robust over a range of different temperature and time combinations, and (e) tolerant to at least 50% water in the biomass. Unlike gravimetric lipid quantification, which can over- or underestimate the lipid content, whole biomass transesterification reflects the true potential fuel yield of algal biomass. We report here on the comparison of the yield of FAMEs by using different catalysts and catalyst combinations, with the acid catalyst HCl providing a consistently high level of conversion of fatty acids with a precision of 1.9% relative standard deviation. We investigate the influence of reaction time, temperature, and biomass water content on the measured FAME content and profile for 4 different samples of algae (replete and deplete Chlorella vulgaris, replete Phaeodactylum tricornutum, and replete Nannochloropsis sp.). We conclude by demonstrating a full mass balance closure of all fatty acids around a traditional lipid extraction process. (orig.)

  15. Variação do potencial total da água em uma toposseqüência de solos de tabuleiro, durante dois anos Total water potential variation in a soil table land topsequence, during two years

    Directory of Open Access Journals (Sweden)

    Luciano da Silva Souza

    2001-02-01

    Full Text Available O trabalho teve como objetivo avaliar quinzenalmente, em 1996 e 1997, a variação do potencial total da água ao longo do tempo, em solos de uma toposseqüência de tabuleiro localizada em Sapeaçu, BA. Esta toposseqüência tinha as seguintes características: a comprimento de 190 m; b declividade média de 0,097 m m-1; c cultivo com laranja; d Latossolo Amarelo argissólico coeso, no terço superior; e Argissolo Amarelo coeso, no terço médio; f Argissolo Acinzentado não coeso, no terço inferior. A umidade do solo foi medida com sonda de nêutrons, nas profundidades de 0,30, 0,70, 1,10 e 1,50 m. Com base nas respectivas curvas de retenção, obteve-se o potencial matricial e, em seguida, o potencial total da água, para cada solo, profundidade e tempo. A camada coesa dificulta o fluxo de água no solo, tanto no processo de molhamento como no de secamento. Em conseqüência, o potencial total da água em solos com camada coesa varia bruscamente na camada mais superficial, ao longo do tempo, e mais lentamente nas camadas mais profundas. Em solo não coeso, a variação brusca do potencial ocorre apenas na camada mais superficial. O limite de tensão de água no solo de -1.500 kPa como sendo o ponto de murchamento permanente não se aplica à cultura dos citros.The objective of this work was to evaluate, fortnightly, during 1996/1997, the total soil water potential variation in a tableland topsequence in Sapeaçu county, BA, Brazil. This topsequence had the following characteristics: a length of 190 m; b slope of 0.097 m m-1; c orange as growing crop; d the upper third with a cohesive argisolic Yellow Latosol; e the middle third with a cohesive Yellow Argisol; and f the lower third with a non-cohesive Gray Argisol. Soil water was estimated by neutron probe at depths of0.30, 0.70, 1.10, and 1.50 m. Based on water retention curves, matric potential and, in sequence, total soil water potential were determined, for each soil and depth in

  16. Saving oil in a hurry

    Energy Technology Data Exchange (ETDEWEB)

    none

    2005-07-01

    During 2004, oil prices reached levels unprecedented in recent years. Though world oil markets remain adequately supplied, high oil prices do reflect increasingly uncertain conditions. Many IEA member countries and non-member countries alike are looking for ways to improve their capability to handle market volatility and possible supply disruptions in the future. This book aims to provide assistance. It provides a new, quantitative assessment of the potential oil savings and costs of rapid oil demand restraint measures for transport. Some measures may make sense under any circumstances; others are primarily useful in emergency situations. All can be implemented on short notice ? if governments are prepared. The book examines potential approaches for rapid uptake of telecommuting, ?ecodriving?, and car-pooling, among other measures. It also provides methodologies and data that policymakers can use to decide which measures would be best adapted to their national circumstances. This ?tool box? may help countries to complement other measures for coping with supply disruptions, such as use of strategic oil stocks.

  17. Energy-saving motor; Energiesparmotor

    Energy Technology Data Exchange (ETDEWEB)

    Lindegger, M.

    2002-07-01

    This report for the Swiss Federal Office of Energy (SFOE) describes the development and testing of an advanced electrical motor using a permanent-magnet rotor. The aims of the project - to study the technical feasibility and market potential of the Eco-Motor - are discussed and the three phases of the project described. These include the calculation and realisation of a 250-watt prototype operating at 230 V, the measurement of the motor's characteristics as well as those of a comparable asynchronous motor on the test bed at the University of Applied Science in Lucerne, Switzerland, and a market study to establish if the Eco-Motor and its controller can compete against normal asynchronous motors. Also, the results of an analysis of the energy-savings potential is made, should such Eco-Motors be used. Detailed results of the three phases of the project are presented and the prospects of producing such motors in Switzerland for home use as well as for export are examined.

  18. Estimates of Savings Achievable from Irrigation Controller

    Energy Technology Data Exchange (ETDEWEB)

    Williams, Alison; Fuchs, Heidi; Whitehead, Camilla Dunham

    2014-03-28

    This paper performs a literature review and meta-analysis of water savings from several types of advanced irrigation controllers: rain sensors (RS), weather-based irrigation controllers (WBIC), and soil moisture sensors (SMS).The purpose of this work is to derive average water savings per controller type, based to the extent possible on all available data. After a preliminary data scrubbing, we utilized a series of analytical filters to develop our best estimate of average savings. We applied filters to remove data that might bias the sample such as data self-reported by manufacturers, data resulting from studies focusing on high-water users, or data presented in a non-comparable format such as based on total household water use instead of outdoor water use. Because the resulting number of studies was too small to be statistically significant when broken down by controller type, this paper represents a survey and synthesis of available data rather than a definitive statement regarding whether the estimated water savings are representative.

  19. Saving-Based Asset Pricing

    DEFF Research Database (Denmark)

    Dreyer, Johannes Kabderian; Schneider, Johannes; T. Smith, William

    2013-01-01

    This paper explores the implications of a novel class of preferences for the behavior of asset prices. Following a suggestion by Marshall (1920), we entertain the possibility that people derive utility not only from consumption, but also from the very act of saving. These ‘‘saving-based’’ prefere...

  20. Geology of Woman Saving Concept

    Directory of Open Access Journals (Sweden)

    Shayesteh Madani

    2014-09-01

    Full Text Available Money is lubricant and an instrument for economic transaction. Money social dimension has increased over time, transforming it from a sole economic instrument to a device for various transactions. Money economic value in society is indicated through different forms, one of which is saving, in the sense of money accumulation and its use under specific future circumstances. Women, who form half of the society, take specific approaches to money and savings. The current research aims to investigate the perspectives and changing attitude strategy to money and saving among married women. The participants of this study include 20 to 70 year-old employed household married women who were observed phenomenologically and interviewed qualitatively on saving through.   The findings of this study demonstrated women perspectives on various types of saving, ways of saving, transfer methods, saving consumption forms and their mechanism. It also revealed that while money is an economic instrument and possess the economic material; attitudes and acts related to money are influenced by social conditions that has consequently turned saving into a social phenomenon.

  1. Prescription Program Provides Significant Savings

    Science.gov (United States)

    Rowan, James M.

    2010-01-01

    Most school districts today are looking for ways to save money without decreasing services to its staff. Retired pharmacist Tim Sylvester, a lifelong resident of Alpena Public Schools in Alpena, Michigan, presented the district with a pharmaceuticals plan that would save the district money without raising employee co-pays for prescriptions. The…

  2. Comparison of total polyphenols content and antioxidant potential of wines from ‘Welschriesling’ and ‘Sauvignon Blanc’ varieties during ageing on fine lees

    Directory of Open Access Journals (Sweden)

    Jasna Lužar

    2016-10-01

    Full Text Available Phenolic compounds are key components of wine, since they contribute to wine characteristics such as colour, astringency and bitterness. They also act like antioxidants, with mechanisms involving free-radical scavenging that could prevent cardiovascular diseases and cancer. The aim of the present work was to compare the obtained results of total polyphenols content and antioxidant potential (AOP of several white wines (welschriesling and sauvignon blanc during ageing on fine lees. The total polyphenols content decreased in average for 16.1 % in welschriesling wines and for 18.7 % in sauvignon blanc wines in the period of three months of wine ageing on lees. In the same period AOP of wines decreased in average for 16.0 % in welschriesling wines and for 8.0 % in sauvignon blanc wines. Expectedly, the samples with added oak chips in grape must had higher antioxidant potential than others.

  3. Social and psychological barriers to private retirement savings in Hong Kong.

    Science.gov (United States)

    Chou, Kee-Lee; Yu, Kar-Ming; Chan, Wai-Sum; Chan, Alfred C M; Lum, Terry Y S; Zhu, Alex Y F

    2014-01-01

    Using a phone survey conducted among Hong Kong workers, we examined the association of institutional, social, and psychological factors with engagement in both private retirement savings and the total amount of savings. Alarmingly, this study demonstrates that approximately 42% of Hong Kong workers do not save privately for their retirement. We found that age, education, number of children, support from spouse and friends, social regulation, perceived financial knowledge, and financial management capacity are associated with engagement in private retirement savings. Among those who saved, age, education, perceived financial knowledge, and financial management capacity are related to the amount of savings. Measures that could increase the social support for retirement savings as well as enhance their financial knowledge and management ability should be developed and implemented so that more workers engage in private retirement savings. A promising policy option for the Hong Kong government is to offer a tax incentive to promote additional savings for old-age income protection.

  4. Multi-fuctional heat recovery systems. Really energy saving; Multifunktionale Waermerueckgewinnung. Wie man wirklich Energie spart

    Energy Technology Data Exchange (ETDEWEB)

    Schilling, Heinz [SEW Systemtechnik fuer Energierecycling und Waermeflussbegrenzung GmbH, Kempen (Germany)

    2009-10-15

    An energy saving leeds only to a correct optimized operation, if a demand-oriented total design is integrated into the building. In special for air-conditioning energy saving measures are presented and essential criteria named, to save in fact effectively, efficiently, reliably and profitably energy and enhance simultanously user quality. (orig./GL)

  5. Energy saving baking methods. Energibesparende bagemetoder

    Energy Technology Data Exchange (ETDEWEB)

    Gry, P.

    1988-01-01

    The project ''Energy Saving Baking Methods'', run as part of the Energy Research Project-1984, and has as its aim to investigate potentials for energy saving by employing microwaves in the baking process. The project is a follow-up of the Nordic Industry Fund project which was completed in 1983. Smaller test ovens with IR long waves, warm air convection and microwaves of 2,47 GHz were used. Measurements of heat distribution from all three energy sources have been made. Extensive experiments have been carried out in order to develope baking methods for white loaves which are energy saving, but where the quality of the bread does not undergo any form of deterioration. Tests were made using microwaves alone, and in combination with hot air and IR. A resulting saving 35% baking time was achieved, and a further reduction of baking time can be reached where a greater improvement of energy distribution can take place, especially in the case of microwaves and IR. (AB).

  6. Exploring Demand Charge Savings from Commercial Solar

    Energy Technology Data Exchange (ETDEWEB)

    Darghouth, Naim [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Barbose, Galen [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Mills, Andrew [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Wiser, Ryan [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Gagnon, Pieter [National Renewable Energy Lab. (NREL), Golden, CO (United States); Bird, Lori [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2017-07-31

    Commercial retail electricity rates commonly include a demand charge component, based on some measure of the customer’s peak demand. Customer-sited solar PV can potentially reduce demand charges, but the magnitude of these savings can be difficult to predict, given variations in demand charge designs, customer loads, and PV generation profiles. Moreover, depending on the circumstances, demand charges from solar may or may not align well with associated utility cost savings. Lawrence Berkeley National Laboratory (Berkeley Lab) and the National Renewable Energy Laboratory (NREL) are collaborating in a series of studies to understand how solar PV can reduce demand charge levels for a variety of customer types and demand charges designs. Previous work focused on residential customs with solar. This study, instead, focuses on commercial customers and seeks to understand the extent and conditions under which rooftop can solar reduce commercial demand charges. To answer these questions, we simulate demand charge savings for a broad range of commercial customer types, demand charge designs, locations, and PV system characteristics. This particular analysis does not include storage, but a subsequent analysis in this series will evaluate demand charge savings for commercial customers with solar and storage.

  7. Analysis of the effect and potential of energy conservation in China

    International Nuclear Information System (INIS)

    He Jiankun; Liu Bin; Zhang Aling

    2006-01-01

    In this paper, a quantitative algorithm for direct and indirect energy savings is developed based on the database analysis of China's energy consumption per GDP in the last two decades. The result shows that direct energy savings due to improved energy conversion and end-use utilization efficiencies only account for 26.5% of the total energy savings, and that indirect energy savings due to increased added value of products, product shifts, and structure shifts in industries account for 73.5% of the total energy savings. Factors affecting indirect energy savings are then analyzed, and total energy system efficiencies and direct energy savings in 2020 are quantitatively estimated, which shows that enlarging indirect energy savings is a more crucial task for China's macro-energy conservation in the future. The paper suggests that China should pay more attention to indirect energy savings to improve the energy utilization output benefits by increasing the added value of products, optimizing product and industry structures, and improving production technologies. The potential of indirect energy savings in China is more significant compared with developed countries

  8. Optimizing Energy Savings from Direct-DC in U.S. Residential Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Garbesi, Karina; Vossos, Vagelis; Sanstad, Alan; Burch, Gabriel

    2011-10-13

    An increasing number of energy efficient appliances operate on direct current (DC) internally, offering the potential to use DC from renewable energy systems directly and avoiding the losses inherent in converting power to alternating current (AC) and back. This paper investigates that potential for net-metered residences with on-site photovoltaics (PV) by modeling the net power draw of the ‘direct-DC house’ with respect to today’s typical configuration, assuming identical DC-internal loads. Power draws were modeled for houses in 14 U.S. cities, using hourly, simulated PV-system output and residential loads. The latter were adjusted to reflect a 33% load reduction, representative of the most efficient DC-internal technology, based on an analysis of 32 electricity end-uses. The model tested the effect of climate, electric vehicle (EV) loads, electricity storage, and load shifting on electricity savings; a sensitivity analysis was conducted to determine how future changes in the efficiencies of power system components might affect savings potential. Based on this work, we estimate that net-metered PV residences could save 5% of their total electricity load for houses without storage and 14% for houses with storage. Based on residential PV penetration projections for year 2035 obtained from the National Energy Modeling System (2.7% for the reference case and 11.2% for the extended policy case), direct-DC could save the nation 10 trillion Btu (without storage) or 40 trillion Btu (with storage). Shifting the cooling load by two hours earlier in the day (pre-cooling) has negligible benefits for energy savings. Direct-DC provides no energy savings benefits for EV charging, to the extent that charging occurs at night. However, if charging occurred during the day, for example with employees charging while at work, the benefits would be large. Direct-DC energy savings are sensitive to power system and appliance conversion efficiencies but are not significantly

  9. Use of different spices as potential natural antioxidant additives on cooked beans (Phaseolus vulgaris). Increase of DPPH radical scavenging activity and total phenolic content.

    Science.gov (United States)

    Pereira, Marina Pelincer; Tavano, Olga Luisa

    2014-12-01

    Herbs and spices, excellent sources of phenolic compounds, can be considered potential antioxidant additives. The use of spices must strike a balance between their potential antioxidant capabilities during preparation and the flavor acceptance, in order to avoid rejection of the food. The aimed of this study is to evaluate the influence of different spices and their concentrations on cooked common beans, focusing its potential as antioxidant additives. Onion, parsley, spring onion, laurel and coriander increased the antioxidant activity of preparation when used at 7.96 g of onion, 1.06 g parsley, 3.43 g spring onion, 0.25 g laurel (dry leaves), and 0.43 g coriander/100 g of cooked beans. Besides, these spices concentrations enhance total phenolics and alter the mixture protein digestibility minimally. For garlic samples it was not possible to establish a concentration that increases the antioxidant activity of cooked beans.

  10. E-Box. A residential gateway for cost saving and sustainability. Integration of Internet and ICT-networks for energy conservation services. Architecture and interface description of energy- and cost saving potential; E-Box. Een 'residential gateway' voor kostenbesparing en duurzaamheid. Integratie Internet en ICT-netwerken voor energiebesparingsdiensten. Architectuur en interface beschrijving Energie- en kostenbesparingspotentieel

    Energy Technology Data Exchange (ETDEWEB)

    Kamphuis, I.G. [ECN Duurzame Energie in de Gebouwde Omgeving DEGO, Petten (Netherlands)

    2003-01-01

    The results of a study on using new information and communication technology in small-scale energy management systems on the level of individual households are presented. Detailed requirements are formulated for such an energy management system. A hardware and software architecture is proposed based on existing standards for delivering service applications. A large part of the energy management functionality for such a E-box for energy efficiency and cost control has been implemented in a software prototype. The results of prototype simulation studies indicate that there is a cost saving potential and a potential for improved embedding of small scale, sustainable energy generators, if operations of appliances are co-ordinated in view of real-time market price signals. The potential (spread in cost plus or minus 15%) is highest for combined operation of small micro-CHP (Stirling motor powered or fuel cell installations) satisfying a house's heat demand with laundry washing and drying processes in a real time electricity pricing situation. A similar increase in cost effectiveness can be achieved, if buffering of energy-carriers (electricity or heat) is used. Possible market and business models for implementing the functionality of an E-box are dealt with and some possible implementation opportunities in a real-time price liberalised end user energy consumption market are discussed. [Dutch] De resultaten van een haalbaarheidsstudie naar de mogelijkheden van het gebruik van Internet-technologie en kleinschalige ICT-netwerken voor het opzetten van energie- en kosten-besparingsdiensten in woningen worden besproken. Vanuit de context van bestaande energie monitoring en management toepassingen in utiliteitsgebouwen wordt een vertaalslag gemaakt naar woningen. Aan de hand van een inventarisatie en definitie van een aantal voorbeeldtoepassingen is een globale vereistenspecificatie voor een energiemanagement systeem in woningen opgesteld. In deze vereistenspecificatie

  11. 12 CFR 561.43 - Savings association.

    Science.gov (United States)

    2010-01-01

    ..., chartered under section 5 of the Act, or a building and loan, savings and loan, or homestead association, or... 12 Banks and Banking 5 2010-01-01 2010-01-01 false Savings association. 561.43 Section 561.43... AFFECTING ALL SAVINGS ASSOCIATIONS § 561.43 Savings association. The term savings association means a...

  12. Public administration electricity savings. Offentlige energibesparelser; Nyere danske erfaringer

    Energy Technology Data Exchange (ETDEWEB)

    Gjelstrup, G

    1991-01-01

    Analysis on how different types of public authorities experienced carrying out electricity savings showed that the individual public authority's internal political-administrative organizational form is of major importance for the possibilities of realizing potential electricity savings. In addition, it can be concluded that only certain public authorities have utilized external assistance in connection with effecting electricity savings. In these cases there has been some accordance between the particular authority's internal, political-administrative, organization and the organizational form presupposed in the external assistance offered. In spite of this, the public authorities in question have, in general, not progressed very far with electricity savings. Part of the reason for this lies namely in the fact that the special importance the mode of organization has for electricity savings, has been overlooked in this type of assistance. (CLS) 43 refs.

  13. Public administration electricity savings. Offentlige energibesparelser; Nyere danske erfaringer

    Energy Technology Data Exchange (ETDEWEB)

    Gjelstrup, G.

    1991-01-01

    Analysis on how different types of public authorities experienced carrying out electricity savings showed that the individual public authority's internal political-administrative organizational form is of major importance for the possibilities of realizing potential electricity savings. In addition, it can be concluded that only certain public authorities have utilized external assistance in connection with effecting electricity savings. In these cases there has been some accordance between the particular authority's internal, political-administrative, organization and the organizational form presupposed in the external assistance offered. In spite of this, the public authorities in question have, in general, not progressed very far with electricity savings. Part of the reason for this lies namely in the fact that the special importance the mode of organization has for electricity savings, has been overlooked in this type of assistance. (CLS) 43 refs.

  14. Reinforcement Learning and Savings Behavior*

    Science.gov (United States)

    Choi, James J.; Laibson, David; Madrian, Brigitte C.; Metrick, Andrew

    2009-01-01

    We show that individual investors over-extrapolate from their personal experience when making savings decisions. Investors who experience particularly rewarding outcomes from saving in their 401(k)—a high average and/or low variance return—increase their 401(k) savings rate more than investors who have less rewarding experiences with saving. This finding is not driven by aggregate time-series shocks, income effects, rational learning about investing skill, investor fixed effects, or time-varying investor-level heterogeneity that is correlated with portfolio allocations to stock, bond, and cash asset classes. We discuss implications for the equity premium puzzle and interventions aimed at improving household financial outcomes. PMID:20352013

  15. Can health promotion programs save Medicare money?

    Directory of Open Access Journals (Sweden)

    Ron Z Goetzel

    2007-04-01

    Full Text Available Ron Z Goetzel1, David Shechter2, Ronald J Ozminkowski1, David C Stapleton3, Pauline J Lapin4, J Michael McGinnis5, Catherine R Gordon6, Lester Breslow71Institute for Health and Productivity Studies, Cornell University, Washington, DC; 2Health and Productivity Research, Thomson Medstat, Santa Barbara, CA; 3Cornell Institute for Policy Research, Cornell University, Washington, DC; 4Office of Research, Development, and Information, Centers for Medicare and Medicaid Services, Baltimore, MD; 5National Academy of Sciences, Institute of Medicine, The National Academies, Washington, DC; 6Office of the Director, Centers for Disease Control and Prevention, Washington, DC; 7UCLA School of Public Health, Dept. of Health Services, Los Angeles, CA, USAAbstract: The impact of an aging population on escalating US healthcare costs is influenced largely by the prevalence of chronic disease in this population. Consequently, preventing or postponing disease onset among the elderly has become a crucial public health issue. Fortunately, much of the total burden of disease is attributable to conditions that are preventable. In this paper, we address whether well-designed health promotion programs can prevent illness, reduce disability, and improve the quality of life. Furthermore, we assess evidence that these programs have the potential to reduce healthcare utilization and related expenditures for the Medicare program. We hypothesize that seniors who reduce their modifiable health risks can forestall disability, reduce healthcare utilization, and save Medicare money. We end with a discussion of a new Senior Risk Reduction Demonstration, which will be initiated by the Centers for Medicare and Medicaid Services in 2007, to test whether risk reduction programs developed in the private sector can achieve health improvements among seniors and a positive return on investment for the Medicare program.Keywords: health promotion, return on investment, Medicare, financial

  16. Overview of contractual savings institutions

    OpenAIRE

    Vittas, Dimitri; Skully, Michael

    1991-01-01

    Contractual savings institutions include national provident funds, life insurance companies, private pension funds, and funded social pension insurance systems. They have long-term liabilities and stable cash flows and are therefore ideal providers of term finance, not only to government and industry, but also to municipal authorities and the housing sector. Except for Singapore, Malaysia, and a few other countries, most developing countries have small and insignificant contractual savings in...

  17. The rise of corporate savings

    OpenAIRE

    Roc Armenter

    2012-01-01

    Over the past few decades, several developed economies have experienced large changes in how much households and firms save. In fact, a sharp increase in firms’ savings behavior has changed the net position of the (nonfinancial) corporate sector vis-à-vis the rest of the economy. ; Why have firms in the business of producing goods or services become lenders? This is quite at odds with traditional models of corporate finance, which suggest that firms issue debt and equity to fund their operati...

  18. Efficient energy-saving targets for APEC economies

    International Nuclear Information System (INIS)

    Hu, J.-L.; Kao, C.-H.

    2007-01-01

    Energy-saving target ratios (ESTR) for 17 APEC economies during 1991-2000 are computed in a total-factor framework. All nominal variables are transformed into real variables by the purchasing power parity (PPP) at the 1995 price level. The data envelopment analysis (DEA) approach is used to find the energy-saving target (EST) for APEC economies without reducing their maximum potential gross domestic productions (GDPs) in each year. Energy, labor, and capital are the three inputs, while GDP is the single output. Our major findings are as follows: (1) China has the largest EST up to almost half of its current usage. (2) Hong Kong, the Philippines, and the United States have the highest energy efficiency. (3) The energy efficiency generally increases for APEC economies except for Canada and New Zealand. (4) Chile, Mexico, and Taiwan have significantly improved their energy efficiency in the last 5 years. (5) An inverted U-shape relation exists between per capita EST and per capita GDP. (6) ESTR has a positive relation with the value-added percentage of GDP of the industry sector and a negative relation with that of the service sector

  19. Total System Performance Assessment, 1993: An evaluation of the potential Yucca Mountain repository, B00000000-01717-2200-00099, Rev. 01

    International Nuclear Information System (INIS)

    Andrews, R.W.; Dale, T.F.; McNeish, J.A.

    1994-03-01

    Total System Performance Assessments are an important component in the evaluation of the suitability of Yucca Mountain, Nevada as a potential site for a mined geologic repository for the permanent disposal of high-level radioactive wastes in the United States. The Total System Performance Assessments are conducted iteratively during the site characterization to identify issues which should be addressed by the characterization and design activities as well as providing input to regulatory/licensing and programmatic decisions. During fiscal years 1991 and 1992, the first iteration of Total System Performance Assessment (hereafter referred to as TSPA 1991) was completed by Sandia National Laboratories and Pacific Northwest Laboratory. Beginning in fiscal year 1993, the Civilian Radioactive Waste Management System Management and Operating Contractor was assigned the responsibility to plan, coordinate, and contribute to the second iteration of Total System Performance Assessment (hereafter referred to as TSPA 1993). This document presents the objectives, approach, assumptions, input, results, conclusions, and recommendations associated with the Management and Operating Contractor contribution to TSPA 1993. A parallel effort was conducted by Sandia National Laboratories and is reported in Wilson et al. (1994, in press)

  20. Cell Size Influences the Reproductive Potential and Total Lifespan of the Saccharomyces cerevisiae Yeast as Revealed by the Analysis of Polyploid Strains

    Directory of Open Access Journals (Sweden)

    Renata Zadrag-Tecza

    2018-01-01

    Full Text Available The total lifespan of the yeast Saccharomyces cerevisiae may be divided into two phases: the reproductive phase, during which the cell undergoes mitosis cycles to produce successive buds, and the postreproductive phase, which extends from the last division to cell death. These phases may be regulated by a common mechanism or by distinct ones. In this paper, we proposed a more comprehensive approach to reveal the mechanisms that regulate both reproductive potential and total lifespan in cell size context. Our study was based on yeast cells, whose size was determined by increased genome copy number, ranging from haploid to tetraploid. Such experiments enabled us to test the hypertrophy hypothesis, which postulates that excessive size achieved by the cell—the hypertrophy state—is the reason preventing the cell from further proliferation. This hypothesis defines the reproductive potential value as the difference between the maximal size that a cell can reach and the threshold value, which allows a cell to undergo its first cell cycle and the rate of the cell size to increase per generation. Here, we showed that cell size has an important impact on not only the reproductive potential but also the total lifespan of this cell. Moreover, the maximal cell size value, which limits its reproduction capacity, can be regulated by different factors and differs depending on the strain ploidy. The achievement of excessive size by the cell (hypertrophic state may lead to two distinct phenomena: the cessation of reproduction without “mother” cell death and the cessation of reproduction with cell death by bursting, which has not been shown before.

  1. Constitutive melanin density is associated with higher 25-hydroxyvitamin D and potentially total body BMD in older Caucasian adults via increased sun tolerance and exposure.

    Science.gov (United States)

    Thompson, M J W; Jones, G; Aitken, D A

    2018-06-01

    Greater skin pigmentation reduces dose equivalent cutaneous vitamin D3 production, potentially impacting lifetime vitamin D status and fracture risk. We show that melanin density was positively associated with 25-hydroxyvitamin D and total body bone mineral density. These relationships were partially explained by greater sun exposure due to more permissive skin phenotype. Higher cutaneous melanin reduces vitamin D3 production. This may impact lifetime vitamin D status and increase fracture risk. This study aimed to describe the relationship between spectrophotometrically determined constitutive melanin density, osteoporotic risk factors and potential intermediaries in a cohort of exclusively older Caucasian adults. One thousand seventy-two community-dwelling adults aged 50-80 years had constitutive melanin density quantified using spectrophotometry. Sun exposure, skin phenotype, non-melanoma skin cancer (NMSC) prevalence and smoking status were assessed by questionnaire. Bone mineral density (BMD), falls risk, physical activity and 25-hydroxyvitamin D were measured using DXA, the short form Physiological Profile Assessment, pedometer and radioimmunoassay, respectively. Higher melanin density was independently associated with greater ability to tan (RR = 1.27, p density and sun exposure (RR = 1.05-1.11, p density (β = 1.71-2.05, p = 0.001). The association between melanin density and total body BMD (β = 0.007, p = 0.04) became non-significant after adjustment for 25-hydroxyvitamin D. There was no association between melanin density and physical activity, falls risk or BMD at other sites. Our data support a model of higher constitutive melanin density underpinning a less photosensitive skin phenotype, permitting greater sun exposure with fewer sequelae and yielding higher 25-hydroxyvitamin D and, potentially, total body BMD.

  2. Energy saving certificates: an improved instrument

    International Nuclear Information System (INIS)

    2016-02-01

    This report first presents Energy Saving Certificates as one of among other instruments aimed at reducing energy consumption, and indicates how the French consumer is concerned. The benefits of this instrument are outlined: low cost, autonomy, awareness-raising, quantitative assessment of achieved energy savings. Its objectives and results since its creation in 2006 are commented, and the report outlines that this type of instrument is spreading over Europe. The authors show that its efficiency has been improved along the years due to a periodic review of standardised operation sheets, a simplification of the declaration, and an optimization of related programmes. Besides, targets have been better identified. The report outlines that assessment and controls must however be strengthened in order to reduce financial risks and potential drifts. Answers to this report by the concerned minister and ADEME are provided

  3. 76 FR 16477 - General Reporting and Recordkeeping by Savings Associations and Savings and Loan Holding Companies

    Science.gov (United States)

    2011-03-23

    ... Savings Associations and Savings and Loan Holding Companies AGENCY: Office of Thrift Supervision (OTS...), 12 CFR 562.4 (audit of savings association, savings and loan holding company, or affiliate), 12 CFR... the savings association), 12 CFR 584.1(f) (books and records of each savings and loan holding company...

  4. A model to estimate cost-savings in diabetic foot ulcer prevention efforts.

    Science.gov (United States)

    Barshes, Neal R; Saedi, Samira; Wrobel, James; Kougias, Panos; Kundakcioglu, O Erhun; Armstrong, David G

    2017-04-01

    Sustained efforts at preventing diabetic foot ulcers (DFUs) and subsequent leg amputations are sporadic in most health care systems despite the high costs associated with such complications. We sought to estimate effectiveness targets at which cost-savings (i.e. improved health outcomes at decreased total costs) might occur. A Markov model with probabilistic sensitivity analyses was used to simulate the five-year survival, incidence of foot complications, and total health care costs in a hypothetical population of 100,000 people with diabetes. Clinical event and cost estimates were obtained from previously-published trials and studies. A population without previous DFU but with 17% neuropathy and 11% peripheral artery disease (PAD) prevalence was assumed. Primary prevention (PP) was defined as reducing initial DFU incidence. PP was more than 90% likely to provide cost-savings when annual prevention costs are less than $50/person and/or annual DFU incidence is reduced by at least 25%. Efforts directed at patients with diabetes who were at moderate or high risk for DFUs were very likely to provide cost-savings if DFU incidence was decreased by at least 10% and/or the cost was less than $150 per person per year. Low-cost DFU primary prevention efforts producing even small decreases in DFU incidence may provide the best opportunity for cost-savings, especially if focused on patients with neuropathy and/or PAD. Mobile phone-based reminders, self-identification of risk factors (ex. Ipswich touch test), and written brochures may be among such low-cost interventions that should be investigated for cost-savings potential. Published by Elsevier Inc.

  5. Geothermal heating saves energy

    International Nuclear Information System (INIS)

    Romsaas, Tor

    2003-01-01

    The article reviews briefly a pioneer project for a construction area of 200000 m''2 with residences, business complexes, a hotel and conference centre and a commercial college in Oslo. The energy conservation potential is estimated to be about 60-70 % compared to direct heating with oil, gas or electricity as sources. There will also be substantial reduction in environmentally damaging emissions. The proposed energy central combines geothermal energy sources with heat pump technology, utilises water as energy carrier and uses terrestrial wells for energy storage. A cost approximation is presented

  6. Achieving the 30% Goal: Energy and Cost Savings Analysis of ASHRAE Standard 90.1-2010

    Energy Technology Data Exchange (ETDEWEB)

    Thornton, Brian A.; Rosenberg, Michael I.; Richman, Eric E.; Wang, Weimin; Xie, YuLong; Zhang, Jian; Cho, Heejin; Mendon, Vrushali V.; Athalye, Rahul A.; Liu, Bing

    2011-05-24

    This Technical Support Document presents the energy and cost savings analysis that PNNL conducted to measure the potential energy savings of 90.1-2010 relative to 90.1-2004. PNNL conducted this analysis with inputs from many other contributors and source of information. In particular, guidance and direction was provided by the Simulation Working Group under the auspices of the SSPC90.1. This report documents the approach and methodologies that PNNL developed to evaluate the energy saving achieved from use of ASHRAE/IES Standard 90.1-2010. Specifically, this report provides PNNL’s Progress Indicator process and methodology, EnergyPlus simulation framework, prototype model descriptions. This report covers the combined upgrades from 90.1-2004 to 90.1-2010, resulting in a total of 153 addenda. PNNL has reviewed and considered all 153 addenda for quantitative analysis in the Progress Indicator process. 53 of those are included in the quantitative analysis. This report provides information on the categorization of all of the addenda, a summary of the content, and deeper explanation of the impact and modeling of 53 identified addenda with quantitative savings.

  7. AutoPowerOff plug banks - a story with energy saving perspectives

    Energy Technology Data Exchange (ETDEWEB)

    Hjort Jensen, Anders (The Danish Electricity Saving Trust (Denmark)); Fjordbak, Troels (IT Energy ApS (Denmark))

    2009-07-01

    Denmark uses around 35 TWh of electricity per year, with residential dwellings accounting for around 10 TWh of this figure. Standby consumption comprises around 12% of power used in homes. If every Danish home installed AutoPowerOff plug banks, savings exceeding 500 GWh per year would be possible, equivalent to 5% of household electricity consumption, or 1.5% of the total in Denmark. This paper describes the estimated standby consumption in Danish homes in 2006, and possible energy savings through the use of AutoPowerOff plug banks. The estimates were subsequently used as background information for a 2007-2008 campaign to promote the wider use of these devices in Denmark. In order to increase the sale of AutoPowerOff plug banks by 1 million units, it was agreed that retail chains selling consumer electronics would include an AutoPowerOff when selling a TV or PC. A nationwide TV advertising campaign was launched featuring the names of participating retailers. Sales of AutoPowerOff plug banks in the first 7 months of 2008 passed the 515,000 mark, with over 1 million units now installed in 2.5 million Danish households. Annual savings are estimated to be over 80 GWh, equivalent to 40,000 tons of CO{sub 2}. This equates to potential savings on an EU-wide basis of more than 7 TWh, or 3.6 million tons of CO{sub 2} in Denmark.

  8. Extraction of total polyphenols from hibiscus (Hibiscus sabdariffa L. and waxweed / ‘sete-sangrias’ (Cuphea carthagenensis and evaluation of their antioxidant potential

    Directory of Open Access Journals (Sweden)

    Daniele Begmeier

    2014-02-01

    Full Text Available Current research investigates the extraction process of total polyphenols from hibiscus (Hibiscus sabdariffa L. and waxweed (Brazilian name: ‘sete-sangrias’ (Cuphea carthagenensis and evaluates the antioxidant potential of their extracts. The extraction stage comprised investigation on the following parameters: i solvents (acetone and ethanol pure and fractioned with water; ii variables (temperature, stirring, solvent ratio, time and pH. Total polyphenols were quantified by Folin-Ciocalteau reagent and antioxidant activity was determined by ABTS•+ (2,2′-Azino-bis(3-ethylbenzothiazoline-6-sulfonic acid and DPPH (2,2-diphenyl-1-picrylhydrazyl radical scavenging assay. Results showed that, depending on experimental conditions, total phenolic contents for hibiscus and waxweed ranged between 460.86 mg GAE 100 g-1 and 5012.54 mg GAE 100 g-1 and between 462.86 mg GAE 100 g-1 and 4215.99 mg GAE 100 g-1, respectively. Waxweed had a higher antioxidant activity when compared to that of hibiscus by both ABTS•+ and DPPH. Data showed that hibiscus and waxweed have a significant amount of polyphenols which may be extracted in mild processing conditions and then employed as natural antioxidant sources in industrial processes.

  9. Uranium savings on a once through PWR fuel cycle

    International Nuclear Information System (INIS)

    Cupo, J.V.

    1980-01-01

    A number of alternatives which have the greatest potential for near term savings with minimum plant and fuel modifications have been examined at Westinghouse as part of continued internal assessment and part of NASAP study conducted for DOE pertaining to uranium utilization in a once through PWR fuel cycle. The alternatives which could be retrofitted to existing reactors were examined in more detail in the evaluation since they would have the greater near term impact on U savings

  10. The impact of translucent fabric shades and control strategies on energy savings and visual quality

    Science.gov (United States)

    Wankanapon, Pimonmart

    Translucent fabric shades provide opportunities for building occupants to control sunlight penetration for heat reduction, thermal comfort, and visual quality. Regulating shades affects building energy and can potentially reduce the size of mechanical cooling systems. Shades are not normally included in energy model studies during the design process, even though shades potential impact energy use. This is because the occupants normally leave shades closed a large fraction of the time, but models are generally performed with no shades. Automatic shade control is now available, so it is necessary to understand the impact of shades on visual quality and their energy saving potential in order to optimize their overall performance. There are very limited studies that have address shades and their integrated performance on energy consumption and visual quality. Most of these do not reflected modern shade types and their application. The goals of this study are: First, to determine the impact of shades on total, heating, cooling and lighting energy savings with different design and operation parameters. Second, to study and develop different automatic shade control strategies to promote and optimize energy savings and visual quality. A simulation-based approach using EnergyPlus in a parametric study provide better understanding energy savings under different shade conditions. The parametric runs addressed various building parameters such as geometry, orientation, site climate, glazing/shade properties, and shade control strategies with integrated lighting control. The impact of shades was determined for total building and space heating, cooling and lighting energy savings. The effect of shades on visual quality was studied using EnergyPlus, AGI32 and DAYSIM for several indices such as daylight glare index (DGI), work plane illuminance, luminance ratios and view. Different shade control strategies and integrated lighting control were considered with two translucent fabric

  11. REMINDER Saved Leave Scheme (SLS) : Simplified procedure for the transfer of leave to saved leave accounts

    CERN Multimedia

    HR Division

    2001-01-01

    As part of the process of streamlining procedures, the HR and AS Divisions have jointly developed a system whereby annual and compensatory leave will henceforth be automatically transferred1) to saved leave accounts. Under the provisions of the voluntary saved leave scheme (SLS), a maximum total of 10 days'2)Previously, every person taking part in the scheme has been individually issued with a form for the purposes of requesting the transfer of leave to the leave account and the transfer has then had to be done manually by HR Division. To streamline the procedure, unused leave of all those taking part in the saved leave scheme at the closure of the leave-year accounts will henceforth be transferred automatically to the saved leave account on that date. This simplification is in the interest of all parties concerned. This automatic transfer procedure has a number of advantages for participants in the SLS scheme. First, staff members will no longer have to take any administrative steps. Secondly, the new proced...

  12. Control Evaluation Information System Savings

    Directory of Open Access Journals (Sweden)

    Eddy Sutedjo

    2011-05-01

    Full Text Available The purpose of this research is to evaluate the control of information system savings in the banking and to identify the weaknesses and problem happened in those saving systems. Research method used are book studies by collecting data and information needed and field studies by interview, observation, questioner, and checklist using COBIT method as a standard to assess the information system control of the company. The expected result about the evaluation result that show in the problem happened and recommendation given as the evaluation report and to give a view about the control done by the company. Conclusion took from this research that this banking company has met standards although some weaknesses still exists in the system.Index Terms - Control Information System, Savings

  13. A saving solution.

    Science.gov (United States)

    Mckee, N

    1983-10-01

    Dr. Mujibur Rahaman, senior scientist at the International Center for Diarrheal Disease Research in Bangladesh, was interviewed recently in regard to oral rehydration therapy (ORT), a simple and inexpensive way of treating the loss of essential fluids and minerals that accompanies diarrhea. According to Rahaman, ORT, developed quite a while ago, is recently gaining more publicity and wider acceptance as a menas of replacing the water and electrolytes lost during acute diarrhea attack. The standard ingredients of the ORT mixture, as it is used in Bangladesh, are 3.5 gm of sodium chloride, or common salt, 2.5 gm sodium bicarbonate, and 1 gm of potassium chloride. To this one should add either 20 gm of glucose or 40 gm of sugar. This mixture should be dissolved in 1 liter of plain drinking water. Plain sugar is good enough. How much is needed depends on the severity and the duration of diarrhea. Calculations have shown that, as a rule of thumb, a child of 10-12 kg may require little more than a liter in about 24 hours. If the child has diarrhea of sufficient severity, it may require more than a liter. If the diarrhea is prolonged, it may require 2 liters. For children who are in danger of dying from dehydration, parents are warned to be watchful because further treatment and follow-up may be required. In Bangladesh a national program is currently providing the ORT in remote rural areas. At present about 1/3 of Bangladesh is covered. The national health service is distributing the solution free of cost in the villages where they have health volunteers. Although ORT is simple to make and simple to administer, one has to exercise some degree of caution with it in order to prevent infants getting dangerous symptoms like hypernatremia. ORT makes it possible for health educators to enter into the family. It is not totally correct to say water is the main problem or causative factor in producing diarrhea. In infantile diarrhea, the cause is most often a virus. Viral

  14. Are Women Empowered to Save?

    Directory of Open Access Journals (Sweden)

    Frances Woolley

    2013-12-01

    Full Text Available Female economic empowerment – rising earnings, increased opportunities, greater labour force participation – has given many women the means to save. The shifting of responsibility for retirement security from employers and governments onto individuals has given women a reason to save. But are women actually saving? In this paper, we explore the relationship between the gender dynamics within a family and the accumulation of wealth. We find that little evidence in support of the conventional wisdom that families with a female financial manager save more and repay their debts more often. We find some evidence that male financial management leads to greater savings, and other evidence suggesting that savings patterns have a complex relationship with intra-family gender dynamics. El empoderamiento económico de la mujer – el aumento de los ingresos, mayores oportunidades, mayor participación laboral – ha dado a muchas mujeres los medios para ahorrar. Al pasar la responsabilidad de los ingresos de la jubilación de los empleadores y el gobierno a los individuos ha dado a las mujeres un motivo para ahorrar. ¿Pero realmente ahorran las mujeres? En este artículo se analizan las relaciones entre las dinámicas de género en una familia, y la acumulación de riqueza. Se ha llegado a la conclusión de que hay poca evidencia que apoye la creencia convencional de que las familias en las que una mujer gestiona las financias ahorran más y devuelven sus créditos más frecuentemente. Se ha encontrado alguna evidencia de que la gestión financiera por varones acarrea mayores ahorros, y otras evidencias que sugieren que los patrones de ahorro tienen una relación compleja con las dinámicas de género dentro de la familia.

  15. Cogeneration plant in a pasta factory: Energy saving and environmental benefit

    International Nuclear Information System (INIS)

    Panno, Domenico; Messineo, Antonio; Dispenza, Antonella

    2007-01-01

    Italy produces approximately 4,520,000 tons of pasta annually, which is about 67% of its total productive potential. As factories need electric and thermal energy simultaneously, combined heat and power (CHP) systems are the most suitable. This paper describes a feasibility study of a CHP plant in a pasta factory in Italy while analyzing energy saving and environmental benefits. Commercially available CHP systems suitable for the power range of energy demand in pasta production use reciprocating engines or gas turbines. This study demonstrates how their use can reduce both energy costs and CO 2 equivalent greenhouse gas emission in the environment. An economic analysis was performed following the methodology set out by Italian National Agency for Technology, Energy and Environment (ENEA) based on a discounted cash flow (DCF) method called 'Valore Attuale Netto' (VAN), which uses a cash flow based on the saving of energy when using different energy processes

  16. Saving Face and Group Identity

    DEFF Research Database (Denmark)

    Eriksson, Tor; Mao, Lei; Villeval, Marie-Claire

    2015-01-01

    their self- but also other group members' image. This behavior is frequent even in the absence of group identity. When group identity is more salient, individuals help regardless of whether the least performer is an in-group or an out-group. This suggests that saving others' face is a strong social norm.......Are people willing to sacrifice resources to save one's and others' face? In a laboratory experiment, we study whether individuals forego resources to avoid the public exposure of the least performer in their group. We show that a majority of individuals are willing to pay to preserve not only...

  17. Fuelwood Savings and Carbon Emission Reductions by the Use of Improved Cooking Stoves in an Afromontane Forest, Ethiopia

    Directory of Open Access Journals (Sweden)

    Elisabeth Dresen

    2014-09-01

    Full Text Available In many Sub-Saharan African countries, fuelwood collection is among the most important drivers of deforestation and particularly forest degradation. In a detailed field study in the Kafa region of southern Ethiopia, we assessed the potential of efficient cooking stoves to mitigate the negative impacts of fuelwood harvesting on forests. Eleven thousand improved cooking stoves (ICS, specifically designed for baking Ethiopia’s staple food injera, referred to locally as “Mirt” stoves, have been distributed here. We found a high acceptance rate of the stove. One hundred forty interviews, including users and non-users of the ICS, revealed fuelwood savings of nearly 40% in injera preparation compared to the traditional three-stone fire, leading to a total annual savings of 1.28 tons of fuelwood per household. Considering the approximated share of fuelwood from unsustainable sources, these savings translate to 11,800 tons of CO2 saved for 11,156 disseminated ICS, corresponding to the amount of carbon stored in over 30 ha of local forest. We further found that stove efficiency increased with longer injera baking sessions, which shows a way of optimizing fuelwood savings by adapted usage of ICS. Our study confirms that efficient cooking stoves, if well adapted to the local cooking habits, can make a significant contribution to the conservation of forests and the avoidance of carbon emission from forest clearing and degradation.

  18. Potencial da economia de água potável pelo uso de água pluvial: análise de 40 cidades da Amazônia Potential for potable water savings by using rainwater: an analysis over 40 cities in Amazon

    Directory of Open Access Journals (Sweden)

    Jeferson Alberto de Lima

    2011-09-01

    Full Text Available A escassez de água é um problema cada vez mais severo em todo o mundo devido a fatores como o consumo excessivo de água bruta, as mudanas climáticas, a poluição da água e o consumo insustentável dos recursos hídricos. Sob essas condições, formas tradicionais ou alternativas de recursos hídricos, tais como a água pluvial, estão sendo consideradas como opções atrativas para reduzir o consumo de água potável. Neste contexto, este artigo descreve o cenário de disponibilidade de água na região Amazõnica, Noroeste do Brasil, e avalia o potencial da economia de água potável para o setor residencial em 40 cidades da região. Os resultados indicam que o potencial da economia de água potável varia entre 21 e 100%, dependendo da demanda de água potável verificada nas 40 cidades, com potencial médio de 76%. A prisncipal conclusão desta pesquisa é que, se houvesse um programa do governo para promover a economia de água potável por meio da utilização da água pluvial, haveria significativa economia de água potável e, consequentemente, a preservação dos recursos hídricos na Amazõnia.Water scarcity is an increasingly severe problem worldwide due to some factors, such as the excessive consumption of raw water, climate changes, water pollution, and unsustainable water resource consumption. Under these conditions, traditional or alternative forms of water resource, such as rainwater, are being considered as attractive options to reduce potable water consumption. In this context, this paper describes the water availability scenario in the Amazon region, Brazilian Northeast, and it evaluates the potential for potable water savings estimated for the residential sector of 40 cities in the region. Results indicate that the potential for potable water savings range from 21 to 100% depending on the potable water demand verified in the 40 cities, with an average potential for potable water savings of 76%. The main conclusion is

  19. Acute hypotension in a patient undergoing posttraumatic cervical spine fusion with somatosensory and motor-evoked potential monitoring while under total intravenous anesthesia: a case report.

    Science.gov (United States)

    Cann, David F

    2009-02-01

    Hypotension should be vigilantly prevented in patients with spinal cord injury. Recent advances in neurological, intraoperative monitoring techniques have allowed Certified Registered Nurse Anesthetists to assess the effects of spinal cord ischemia and compression as they occur. This case report describes a young, healthy man who sustained a cervical spine fracture and was scheduled for anterior spinal fusion with somatosensory and motor-evoked potential (MEP) monitoring while under total intravenous anesthesia. This patient experienced a brief period of intraoperative hypotension with evidence of abnormal MEPs. A wake-up test was performed, which showed normal functioning, and the case resumed an uneventful course. Although this scenario resulted in no neurological sequelae, the effects of spinal cord ischemia due to hypotension can lead to permanent, devastating motor and sensory damage.

  20. Potential and limitation of mid-infrared attenuated total reflectance spectroscopy for real time analysis of raw milk in milking lines.

    Science.gov (United States)

    Linker, Raphael; Etzion, Yael

    2009-02-01

    Real-time information about milk composition would be very useful for managing the milking process. Mid-infrared spectroscopy, which relies on fundamental modes of molecular vibrations, is routinely used for off-line analysis of milk and the purpose of the present study was to investigate the potential of attenuated total reflectance mid-infrared spectroscopy for real-time analysis of milk in milking lines. The study was conducted with 189 samples from over 70 cows that were collected during an 18 months period. Principal component analysis, wavelets and neural networks were used to develop various models for predicting protein and fat concentration. Although reasonable protein models were obtained for some seasonal sub-datasets (determination errors protein), the models lacked robustness and it was not possible to develop a model suitable for all the data. Determination of fat concentration proved even more problematic and the determination errors remained unacceptably large regardless of the sub-dataset analyzed or of the spectral intervals used. These poor results can be explained by the limited penetration depth of the mid-infrared radiation that causes the spectra to be very sensitive to the presence of fat globules or fat biofilms in the boundary layer that forms at the interface between the milk and the crystal that serves both as radiation waveguide and sensing element. Since manipulations such as homogenisation are not permissible for in-line analysis, these results show that the potential of mid-infrared attenuated total reflectance spectroscopy for in-line milk analysis is indeed quite limited.

  1. Survey of industrial radioisotope savings

    International Nuclear Information System (INIS)

    1965-01-01

    Only three decades after the discovery of artificial radioactivity and two after radioisotopes became available in quantity, methods employing these as sources or tracers have found widespread use, not only in scientific research, but also in industrial process and product control. The sums spent by industry on these new techniques amount to millions of dollars a year. Realizing the overall attitude of industry to scientific progress - to accept only methods that pay relatively quickly - one can assume that the economic benefits must be of a still larger order of magnitude. In order to determine the extent to which radioisotopes are in daily use and to evaluate the economic benefits derived from such use, IAEA decided to make an 'International Survey on the Use of Radioisotopes in Industry'. In 1962, the Agency invited a number of its highly industrialized Member States to participate in this Survey. Similar surveys had been performed in various countries in the 1950's. However, the approaches and also the definition of the economic benefits differed greatly from one survey to another. Hence, the Agency's approach was to try to persuade all countries to conduct surveys at the same time, concerning the same categories of industries and using the same terms of costs, savings, etc. In total, 24 Member States of the Agency agreed to participate in the survey and in due course they submitted contributions. The national reports were discussed at a 'Study Group Meeting on Radioisotope Economics', convened in Vienna in March 1964. Based upon these discussions, the national reports have been edited and summarized. A publication showing the administration of the Survey and providing all details is now published by the Agency. From the publication it is evident that in general the return of technical information was quite high, of the order of 90%, but, unfortunately the economic response was much lower. However, most of the reports had some bearing on the economic aspects

  2. Energy saving potential of energy services - experimentation on the life cycle of energy conversion equipment; Potentiel d'economies d'energie par les services energetiques - application au cycle de vie des equipements de conversion de l'energie

    Energy Technology Data Exchange (ETDEWEB)

    Dupont, M

    2006-12-15

    Energy efficiency services are growing in Europe but their role is still limited. In order to evaluate the potential, we focused first of all on policy, economical and environmental mechanisms that support their development. European natural gas and electricity markets, that are now almost wholly de-regulated, are analysed and compared to their historical structure. By introducing uncertainty on energy prices, this new deal translates better the real energy costs. Energy performance contracts (EPC) limit the impact of these uncertainties on the customer energy bills by guaranteeing a financial result. As a result of the modelling of these contracts, namely operation and maintenance ones, we prove that they transfer technical and financial risks from building owners to energy service companies (ESCO) making energy saving measures easier and less expensive at the same time. These contracts are relatively widespread for heating or compressed-air processes but remain marginal for air-conditioning systems. So new methods were needed to guarantee on the long terms the efficiency of air-conditioning systems demand (1) to master the process and its performances and (2) to be able to determine precisely the energy saving potential and its realisation costs. A detailed energy audit is thus necessary for which we propose a guidance. Conclusions of audits carried out prove that energy saving potential is mainly located in equipment management and control. These optimizations are not always carried out because of a lack of contractual incentive and due to the weaknesses of audit methods. Through the involvement of an independent expert, the mandatory and regular inspection of air-conditioning systems may allow to verify and guide such practices. A three-step analysis procedure has been developed in order to maximize the inspection potential and to get higher benefits from service contracts. (author)

  3. Total Phenol Content and In Vitro Antioxidant Potential of Helicanthus elastica (Desr. Danser-A Less-explored Indian Mango Mistletoe

    Directory of Open Access Journals (Sweden)

    Koppala Narayana Sunil Kumar

    2014-10-01

    Full Text Available Natural products are an important source of antioxidant molecules like tannins, phenolic compounds, flavonoids, etc., Helicanthus elastica (Desr. Danser (Loranthaceae is one such plant belonging to the category of mistletoe, and grows commonly on the mango trees in India. In the present study, an attempt has been made to assess the antioxidant properties of the plant. Ethanol extract of H. elastica growing on mango tree was studied using different in vitro models. Shade-dried whole plant material was extracted with ethanol by cold percolation. Fifty milligrams of the alcohol extract of H. elastica was weighed and dissolved in 10 ml of methanol. The resultant 5 mg/ml solution was suitably diluted to obtain different concentrations. Total phenol content, reducing power assay, and scavenging of free radicals like nitric oxide, hydroxyl, hydrogen peroxide, and 1,1-diphenyl-2-picrylhydrazyl were studied by standardized in vitro chemical methods using ascorbic acid as the standard. The total phenol content of the plant was found to be 1.89% w/w. The extract showed good reducing power as well as scavenging of free radicals (nitric oxide, hydroxyl, superoxide anion, and hydrogen peroxide at concentrations ranging from 5 to 100 μg/ml. The study revealed the antioxidant potential of H. elastica.

  4. The potential for portable X-ray fluorescence determination of soil copper at ancient metallurgy sites, and considerations beyond measurements of total concentrations.

    Science.gov (United States)

    Tighe, M; Rogan, G; Wilson, S C; Grave, P; Kealhofer, L; Yukongdi, P

    2018-01-15

    Copper (Cu) at ancient metallurgy sites represents the earliest instance of anthropogenically generated metal pollution. Such sites are spread across a wide range of environments from Eurasia to South America, and provide a unique opportunity to investigate the past and present extent and impact of metalworking contamination. Establishing the concentration and extent of soil Cu at archaeometallurgy sites can enhance archaeological interpretations of site use but can also, more fundamentally, provide an initial indication of contamination risk from such sites. Systematic evaluations of total soil Cu concentrations at ancient metalworking sites have not been conducted, due in part to the limitations of conventional laboratory-based protocols. In this paper, we first review what is known about Cu soil concentrations at ancient metallurgy sites. We then assess the benefits and challenges of portable X-ray fluorescence spectrometry (pXRF) as an alternative, rapid technique for the assessment of background and contaminant levels of Cu in soils. We conclude that pXRF is an effective tool for identifying potential contamination. Finally, we provide an overview of some major considerations beyond total Cu concentrations, such as bioavailability assessments, that will need to be considered at such sites to move toward a complete assessment of environmental and human risk. Copyright © 2017 Elsevier Ltd. All rights reserved.

  5. Total protein

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/article/003483.htm Total protein To use the sharing features on this page, please enable JavaScript. The total protein test measures the total amount of two classes ...

  6. Save the Boulders Beach Penguins

    Science.gov (United States)

    Sheerer, Katherine; Schnittka, Christine

    2012-01-01

    Maybe it's the peculiar way they walk or their cute little suits, but students of all ages are drawn to penguins. To meet younger students' curiosity, the authors adapted a middle-school level, penguin-themed curriculum unit called Save the Penguins (Schnittka, Bell, and Richards 2010) for third-grade students. The students loved learning about…

  7. 76 FR 31680 - General Reporting and Recordkeeping by Savings Associations and Savings and Loan Holding Companies

    Science.gov (United States)

    2011-06-01

    ... Savings Associations and Savings and Loan Holding Companies AGENCY: Office of Thrift Supervision (OTS... Savings and Loan Holding Companies. OMB Number: 1550-0011. Form Number: N/A. Description: This information...), 12 CFR 562.4 (audit of savings association, savings and loan holding company, or affiliate), 12 CFR...

  8. Breakthrough Energy Savings with Waterjet Technology

    Energy Technology Data Exchange (ETDEWEB)

    Lee W. Saperstein; R. Larry Grayson; David A. Summers; Jorge Garcia-Joo; Greg Sutton; Mike Woodward; T.P. McNulty

    2007-05-15

    Experiments performed at the University of Missouri-Rolla's Waterjet Laboratory have demonstrated clearly the ability of waterjets to disaggregate, in a single step, four different mineral ores, including ores containing iron, lead and copper products. The study focused mainly on galena-bearing dolomite, a lead ore, and compared the new technology with that of traditional mining and milling to liberate the valuable constituent for the more voluminous host rock. The technical term for the disintegration of the ore to achieve this liberation is comminution. The potential for energy savings if this process can be improved, is immense. Further, if this separation can be made at the mining face, then the potential energy savings include avoidance of transportation (haulage and hoisting) costs to move, process and store this waste at the surface. The waste can, instead, be disposed into the available cavities within the mine. The savings also include the elimination of the comminution, crushing and grinding, stages in the processing plant. Future prototype developments are intended to determine if high-pressure waterjet mining and processing can be optimized to become cheaper than traditional fragmentation by drilling and blasting and to optimize the separation process. The basic new mining process was illustrated in tests on two local rock types, a low-strength sandstone with hematite inclusions, and a medium to high-strength dolomite commonly used for construction materials. Illustrative testing of liberation of minerals, utilized a lead-bearing dolomite, and included a parametric study of the optimal conditions needed to create a size distribution considered best for separation. The target goal was to have 50 percent of the mined material finer than 100 mesh (149 microns). Of the 21 tests that were run, five clearly achieved the target. The samples were obtained as run-of-mine lumps of ore, which exhibited a great deal of heterogeneity within the samples. This

  9. Energy Savings Calculations for Heat Island Reduction Strategies in Baton Rouge, Sacramento and Salt Lake City

    Energy Technology Data Exchange (ETDEWEB)

    Konopacki, S.; Akbari, H.

    2000-03-01

    In 1997, the US Environmental Protection Agency (EPA) established the ''Heat Island Reduction Initiative'', to quantify the potential benefits of Heat Island Reduction (HIR) strategies (i.e., shade trees, reflective roofs, reflective pavements and urban vegetation) to reduce cooling energy use in buildings, lower the ambient air temperature and improve urban air quality in cities, and reduce CO2 emissions from power plants. Under this initiative, the Urban Heat Island Pilot Project (UHIPP) was created with the objective to investigate the potential of HIR strategies in residential and commercial buildings in three initial UHIPP cities: Baton Rouge, Sacramento and Salt Lake City. This paper summarizes our efforts to calculate the annual energy savings, peak power avoidance and annual C02 reduction of HIR strategies in the three initial cities. In this analysis, we focused on three building types that offer most savings potential: single-family residence, office and retail store. Each building type was characterized in detail by old or new construction and with a gas furnace or an electric heat pump. We defined prototypical building characteristics for each building type and simulated the impact of HIR strategies on building cooling and heating energy use and peak power demand using the DOE-2.IE model. Our simulations included the impact of (1) strategically-placed shade trees near buildings [direct effect], (2) use of high-albedo roofing material on building [direct effect], (3) combined strategies I and 2 [direct effect], (4) urban reforestation with high-albedo pavements and building surfaces [indirect effect] and (5) combined strategies 1, 2 and 4 [direct and indirect effects]. We then estimated the total roof area of air-conditioned buildings in each city using readily obtainable data to calculate the metropolitan-wide impact of HIR strategies. The results show, that in Baton Rouge, potential annual energy savings of $15M could be realized by

  10. Energy-saving implications from supply chain improvement: An exploratory study on China's consumer goods retail system

    International Nuclear Information System (INIS)

    Wang, Xi; Cai, Hua; Florig, H. Keith

    2016-01-01

    Despite significant public attentions to green supply chain management, few studies have explicitly addressed the energy implications of consumer-goods supply surplus, especially in developing countries like China. This study explored the energy-saving potential from improving supply chain efficiencies and reducing excess inventory in China's retail system from a life-cycle perspective. Through embodied energy analysis, we found that energy invested pre-manufacture contributed 80–95% of the total energy embodied in consumer products. Although embodied energy intensities had declined by 60–90% since the mid-1990s, the lessened marginal improvements implied that 'low hanging fruits' have largely been captured, and the search for new opportunities for energy-saving is in demand. Positive correlations between total economic inputs and embodied energy in consumer goods indicated possible synergy effect between cost-reduction and energy-saving in supply system management. And structural path analysis identified sector-specific energy management priorities for each retail-related sector. This study suggested that improving supply chain efficiencies provides a promising supplement to China's current industrial energy-efficient projects which target reducing direct energy use per se as an intra-firm cost-saving measure. From the life-cycle perspective, the definition of 'green sector' might have to be reconsidered in China towards a more energy-efficient economy and society.

  11. The efficiency improvement potential for coal, oil and electricity in China's manufacturing sectors

    International Nuclear Information System (INIS)

    Li, Ke; Lin, Boqiang

    2015-01-01

    This paper introduces an improved total-factor ESTR (energy-saving target ratio) index, which combines the sequence technique and the “energy direction” to a DEA (data envelopment analysis) model, in order to measure the possible energy saving potential of a manufacturing sector. Afterward, the energy saving potentials of four different energy carriers, namely coal, gasoline, diesel oil and electricity, for 27 manufacturing sectors during the period of 1998–2011 in China are calculated. The results and its policy implications are as follows: (1) the average ESTRs of coal, gasoline, diesel oil and electricity are 1.714%, 49.939%, 24.465% and 3.487% respectively. Hence, energy saving of manufacturing sectors should put more emphasis on gasoline and diesel oil. (2) The key sectors for gasoline saving is the energy-intensive sectors, while the key sectors for diesel oil saving is the equipment manufacturing sectors. (3) The manufacture of raw chemical materials and chemical products sector not only consumes a large amount of oil, but also has a low efficiency of oil usage. Therefore, it is the key sector for oil saving. (4) Manufacture of tobacco and manufacture of communication equipment, computers and other electronic equipment are the benchmark for the four major energy carriers of energy-saving ratios. - Highlights: • An improved total-factor energy-saving target ratio is proposed. • Energy saving potentials of energy carriers for sectors in 1998–2011 are calculated. • Policy implications for energy savings in sectors and energy carriers are discussed. • Some suggestions for the energy policies of China's economy are discussed

  12. Energy Savings From System Efficiency Improvements in Iowa's HVAC SAVE Program

    Energy Technology Data Exchange (ETDEWEB)

    Yee, S. [Partnership for Advanced Residential Retrofit, Chicago, IL (United States); Baker, J. [Partnership for Advanced Residential Retrofit, Chicago, IL (United States); Brand, L. [Partnership for Advanced Residential Retrofit, Chicago, IL (United States); Wells, J. [Partnership for Advanced Residential Retrofit, Chicago, IL (United States)

    2013-08-01

    The objective of this project is to explore the energy savings potential of maximizing furnace and distribution system performance by adjusting operating, installation, and distribution conditions. The goal of the Iowa HVAC System Adjusted and Verified Efficiency (SAVE) program is to train contractors to measure installed system efficiency as a diagnostic tool to ensure that the homeowner achieves the energy reduction target for the home rather than simply performing a tune-up on the furnace or having a replacement furnace added to a leaky system. The PARR research team first examined baseline energy usage from a sample of 48 existing homes, before any repairs or adjustments were made, to calculate an average energy savings potential and to determine which system deficiencies were prevalent. The results of the baseline study of these homes found that, on average, about 10% of the space heating energy available from the furnace was not reaching the conditioned space. In the second part of the project, the team examined a sample of 10 homes that had completed the initial evaluation for more in-depth study. For these homes, the diagnostic data shows that it is possible to deliver up to 23% more energy from the furnace to the conditioned space by doing system tune ups with or without upgrading the furnace. Replacing the furnace provides additional energy reduction. The results support the author's belief that residential heating and cooling equipment should be tested and improved as a system rather than a collection of individual components.

  13. FY 1997 cost savings report

    International Nuclear Information System (INIS)

    Sellards, J.B.

    1998-01-01

    With the end of the cold war, funding for the Environmental Management program increased rapidly as nuclear weapons production facilities were shut down, cleanup responsibilities increased, and facilities were transferred to the cleanup program. As funding for the Environmental Management (EM) program began to level off in response to Administration and Congressional efforts to balance the Federal budget, the program redoubled its efforts to increase efficiency and get more productivity out of every dollar. Cost savings and enhanced performance are an integral pair of Hanford Site operations. FY1997 was the third year of a cost savings program that was initially defined in FY 1995. The definitions and process remained virtually the same as those used in FY 1996

  14. Energy savings in Polish buildings

    Energy Technology Data Exchange (ETDEWEB)

    Markel, L.C.; Gula, A.; Reeves, G.

    1995-12-31

    A demonstration of low-cost insulation and weatherization techniques was a part of phase 1 of the Krakow Clean Fossil Fuels and Energy Efficient Project. The objectives were to identify a cost-effective set of measures to reduce energy used for space heating, determine how much energy could be saved, and foster widespread implementation of those measures. The demonstration project focused on 4 11-story buildings in a Krakow housing cooperative. Energy savings of over 20% were obtained. Most important, the procedures and materials implemented in the demonstration project have been adapted to Polish conditions and applied to other housing cooperatives, schools, and hospitals. Additional projects are being planned, in Krakow and other cities, under the direction of FEWE-Krakow, the Polish Energie Cities Network, and Biuro Rozwoju Krakowa.

  15. Water Saving Strategies & Ecological Modernisation

    DEFF Research Database (Denmark)

    Hoffmann, Birgitte; Jensen, Jesper Ole; Elle, Morten

    2005-01-01

    Drawing on case studies of water saving campaigns and new collaborations, the pa-per will serve, on the one hand, as an interpretation of the water saving strategy in Co-penhagen in the light of Ecological Modernisation, and on the other hand, as a critical discussion of Ecological Modernisation...... as a frame for understanding resource manage-ment. The water management in Copenhagen has in recent years undergone a rather radi-cal transition. Along with strong drivers for resource management in the region the mu-nicipal water supplier has tested and implemented a number of initiatives to promote sus...... to 125 l/capita/day in 2002. A series of different strategies, targets and tools have been implemented: Emphasizing demand side instead of supply side, using and communicating indicators, formulating goals for reducing water consumption and developing learning processes in water management. A main...

  16. Cost savings through innovative technologies

    International Nuclear Information System (INIS)

    Lankford, J.M.; Jackson, J.P.

    1995-01-01

    Newly developed technologies can and already are saving money. Other technologies under development will provide solutions to problems which are currently impossible or too expensive to address, and still others will offer alternative strategies where baseline approaches are not acceptable to the public. All of these options will be considered as the nation decides what it wishes to accomplish, and fund, to clean up the nuclear weapons complex

  17. Addressing and overcoming barriers for energy savings in business

    DEFF Research Database (Denmark)

    Dirckinck-Holmfeld, Kasper

    Energy savings are generally viewed as an effective way to cut GHG emissions, as there are huge potentials for improvements because of several barriers and constraining factors for implementing otherwise profitable solutions. Several different polity tools have been applied to overcome these barr......Energy savings are generally viewed as an effective way to cut GHG emissions, as there are huge potentials for improvements because of several barriers and constraining factors for implementing otherwise profitable solutions. Several different polity tools have been applied to overcome...

  18. Can the Society for Assisted Reproductive Technology Clinic Outcome Reporting System (SART CORS) be used to accurately report clinic total reproductive potential (TRP)?

    Science.gov (United States)

    Stern, Judy E; Hickman, Timothy N; Kinzer, Donna; Penzias, Alan S; Ball, G David; Gibbons, William E

    2012-04-01

    To assess whether total reproductive potential (TRP), the chance of a live birth from each fresh cycle (fresh cycle plus frozen transfers), could be calculated from the national Society for Assisted Reproductive Technology Clinic Outcome Reporting System (SART CORS) database and whether information not available in SART CORS resulted in significant changes to the TRP calculation. Retrospective study using SART CORS and clinic data. Three assisted reproductive technology clinics. Women undergoing ART. None. Two- and three-year TRPs for 2005 and 2006 were calculated according to patient age at cycle start by linking fresh to frozen cycles up to first live birth. Clinic records were used to adjust for (remove) frozen cycles that used more than one fresh cycle as a source of embryos and for any embryos donated to other patients or research or shipped to another facility before a live birth. TRP was higher than fresh per-cycle rates for most ages at all clinics, although accuracy was compromised when there were fewer than 20 cycles per category. Two- and 3-year TRPs differed in only 2 of 24 calculations. Adjusted TRPs differed less than three percentage points from unadjusted TRPs when volume was sufficient. Clinic TRP can be calculated from SART CORS. Data suggest that calculations of clinic TRP from the national dataset would be meaningful. Copyright © 2012 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.

  19. Urinary and Serum Metabolomics Analyses Uncover That Total Glucosides of Paeony Protect Liver against Acute Injury Potentially via Reprogramming of Multiple Metabolic Pathways

    Directory of Open Access Journals (Sweden)

    Haojie Li

    2017-01-01

    Full Text Available Total glucosides of paeony (TGP have been confirmed to be hepatoprotective. However, the underlying mechanism is largely unclear. In this study, we investigated the metabolic profiles of urine and serum in rats with carbon tetrachloride- (CCl4- induced experimental liver injury and TGP administration by using ultra-performance liquid chromatography-mass spectrometry (UPLC-MS. The vehicle or a single dose of TGP was intragastrically administered to Wistar rats once a day for 14 consecutive days. To induce ALI, 50% CCl4 was injected intraperitoneally into these rats 2 hours after the last time administration of saline of TGP at the 14th day. The results indicated that TGP administration could protect rats from CCl4-induced ALI and alanine aminotransferase (ALT and aspartate aminotransferase (AST elevation, as well as hepatocyte apoptosis and inflammation. Furthermore, metabolomics analysis showed that TGP treatment significantly attenuated CCl4-triggered deregulation of multiple metabolites in both urine and serum, including glycine, alanine, proline, and glutamine. Metabolite set enrichment and pathway analyses demonstrated that amino acid cycling and glutathione metabolism were two main pathways involved in CCl4-induced experimental liver injury and TGP administration. Taken together, these findings revealed that regulation of metabolites potentially plays a pivotal role in the protective effect of TGP on ALI.

  20. Evaluation of methods used to determine realized energy savings

    International Nuclear Information System (INIS)

    Boonekamp, Piet G.M.

    2006-01-01

    Most methods to determine realized total energy savings at national or sectoral level make choices, or neglect problems, which hamper the calculation of sound and useful energy-saving figures. Issues are the choice of the right aggregation level, the appropriate variables to construct a reference energy consumption trend, the energy quantities to be applied and interaction between various effects. Uncertainty margins for results lack in most presentations as well. This paper presents six methods, illustrates the adverse effects of certain choices and problems, and investigates how these methods deal with them. The methods are scored with respect to the issues mentioned above. Finally, a number of improvements are suggested, among which the use of final energy demand expressed in primary energy units, and bottom-up analyses at the level of real saving options. The last option is the more important, as it could provide top-down evaluation results (total savings from decomposition) as well as bottom-up policy monitoring results, both being crucial to new European energy-saving policy

  1. The impact on energy consumption of daylight saving clock changes

    Energy Technology Data Exchange (ETDEWEB)

    Hill, S.I.; Desobry, F. [Department of Engineering, University of Cambridge (United Kingdom); Garnsey, E.W. [Institute for Manufacturing, University of Cambridge (United Kingdom); Chong, Y.-F. [IPA Energy and Water Consulting (United Kingdom)

    2010-09-15

    The focus of this work is an investigation of the effect of prevailing time regime on energy consumption. In particular we perform analysis demonstrating potential energy savings which could be obtained were Great Britain to maintain daylight savings time (DST) over winter, instead of reverting to Greenwich mean time (GMT). We review the literature on the effect of DST on energy consumption and show that this indicates a justification for considering the issue. Our headline result is in agreement with many related studies in that advancing the clock by an hour in winter would lead to energy savings of at least 0.3% of daily demand in Great Britain. In deriving this result we have adopted methodologies currently used in load prediction, in particular Support Vector Regression, to estimate energy demand on a half-hourly basis. Corresponding cost savings are found to be higher (due to the nonlinear increase of costs) and we find them to be on the order of 0.6% over the months considered. In terms of environmental impact we find the saving to be approximately equivalent to 450,000 ton of CO{sub 2}. In deriving these results we adopt a conservative approach such that we consider them lower bounds on any true savings. (author)

  2. The impact on energy consumption of daylight saving clock changes

    International Nuclear Information System (INIS)

    Hill, S.I.; Desobry, F.; Garnsey, E.W.; Chong, Y.-F.

    2010-01-01

    The focus of this work is an investigation of the effect of prevailing time regime on energy consumption. In particular we perform analysis demonstrating potential energy savings which could be obtained were Great Britain to maintain daylight savings time (DST) over winter, instead of reverting to Greenwich mean time (GMT). We review the literature on the effect of DST on energy consumption and show that this indicates a justification for considering the issue. Our headline result is in agreement with many related studies in that advancing the clock by an hour in winter would lead to energy savings of at least 0.3% of daily demand in Great Britain. In deriving this result we have adopted methodologies currently used in load prediction, in particular Support Vector Regression, to estimate energy demand on a half-hourly basis. Corresponding cost savings are found to be higher (due to the nonlinear increase of costs) and we find them to be on the order of 0.6% over the months considered. In terms of environmental impact we find the saving to be approximately equivalent to 450,000 ton of CO 2 . In deriving these results we adopt a conservative approach such that we consider them lower bounds on any true savings.

  3. Transfer And Adoption Of Labour Saving Technologies | Idu ...

    African Journals Online (AJOL)

    The study was carried out to assess the transfer and adoption of labour saving technologies in Apa Local Government area of BenueState. A total sample size One Hundred and Twenty was used in the study. Interview schedule was used to collect the data from respondents. The results revealed that herbicide was adopted ...

  4. Total algorithms

    NARCIS (Netherlands)

    Tel, G.

    We define the notion of total algorithms for networks of processes. A total algorithm enforces that a "decision" is taken by a subset of the processes, and that participation of all processes is required to reach this decision. Total algorithms are an important building block in the design of

  5. Energy saving and emission reduction of China's urban district heating

    International Nuclear Information System (INIS)

    Chen, Xia; Wang, Li; Tong, Lige; Sun, Shufeng; Yue, Xianfang; Yin, Shaowu; Zheng, Lifang

    2013-01-01

    China's carbon dioxide (CO 2 ) emission ranks highest in the world. China is committed to reduce its CO 2 emission by 40% to 45% from the 2005 levels by 2020. To fulfill the target, China's CO 2 emission reduction must exceed 6995 million tons. Energy consumption and CO 2 emission of China's urban district heating (UDH) are increasing. The current policy implemented to improve UDH focuses on replacing coal with natural gas to reduce energy consumption and CO 2 emission to some extent. This paper proposes that heat pump heating (HPH) could serve as a replacement for UDH to help realize energy-saving and emission-reduction goals to a greater extent. The paper also analyzes the impact of this replacement on the heating and power generation sectors. The results show that replacing coal-based UDH with HPH decreases energy consumption and CO 2 emission by 43% in the heating sector. In the power generation sector, the efficiency of power generation at the valley electricity time increases by 0.512%, and the ratio of peak–valley difference decreases by 16.5%. The decreases in CO 2 emission from the heating and power generation sectors cumulatively account for 5.55% of China's total CO 2 emission reduction target in 2020. - Highlights: ► Replacing urban district heating with heat pump heating. ► Impact of heat pump heating on heating and power generation sectors. ► Potential of energy saving and emission reduction for heat pump heating. ► China should adjust current urban heating strategy

  6. Energy Savings for Solar Heating Systems

    DEFF Research Database (Denmark)

    Thür, Alexander; Furbo, Simon; Shah, Louise Jivan

    2004-01-01

    , various simulations of solar heating systems were done for different hot water demands and collector sizes. The result shows that the potential of fuel reduction can be much higher than the solar gain of the solar thermal system. For some conditions the fuel reduction can be up to the double of the solar......In this paper the realistic behaviour and efficiency of heating systems were analysed, based on long term monitoring projects. Based on the measurements a boiler model was evaluated. Comparisons of measured and calculated fuel consumptions showed a good degree of similarity. With the boiler model...... gain due to a strong increase of the system efficiency. As the monitored boilers were not older than 3 years, it can be assumed that the saving potential with older boilers could be even higher than calculated in this paper....

  7. Energy Savings for Solar Heating Systems

    DEFF Research Database (Denmark)

    Thür, Alexander; Furbo, Simon; Shah, Louise Jivan

    2006-01-01

    showed a good degree of similarity. With the boiler model, various simulations of solar domestic hot water heating systems were done for different hot water demands and collector sizes. The result shows that the potential of fuel reduction can be much higher than the solar gain of the solar thermal...... system. For some conditions the fuel reduction can be up to the double of the solar gain due to a strong increase of the system efficiency. As the monitored boilers were not older than 3 years, it can be assumed that the saving potential with older boilers could be even higher than calculated......In this paper the realistic behaviour and efficiency of heating systems were analysed, based on long term monitoring projects. Based on the measurements a boiler model used to calculate the boiler efficiency on a monthly basis was evaluated. Comparisons of measured and calculated fuel consumptions...

  8. Energy savings in the Danish building stock until 2050

    DEFF Research Database (Denmark)

    Wittchen, Kim Bjarne; Kragh, Jesper

    2014-01-01

    are energy upgraded according to the requirements stipulated in the Danish Building Regulations 2010. Furthermore, scenario analyses was made for the potential impact on the energy consumption of introducing different levels of tightening of the energy requirements for existing buildings in the Danish...... Building Regulations. Compliance with the requirements in the Danish Building Regulations will potentially result in energy savings for space heating and domestic hot water around 30 % until 2050. Further tightening of the component insulation level requirements will only result in marginally higher......A study has been conducted analysing the energy savings for space heating and domestic hot water in the Danish building stock due to renovation of building components at the end of their service life. The purpose of the study was to estimate the energy savings until 2050 as building components...

  9. Energy Savings in a Market Economy

    DEFF Research Database (Denmark)

    Nørgaard, Jørgen

    1998-01-01

    The paper outlines the concept of energy savings as opposed to energy efficency. Afterwards are described briefly the up and down role of energy savings in recent Danish energy policy. It discusses the failure of leaving electricity savings and Integrated Resource Planning to the electricity...

  10. 24 CFR 221.1 - Savings clause.

    Science.gov (United States)

    2010-04-01

    ... 24 Housing and Urban Development 2 2010-04-01 2010-04-01 false Savings clause. 221.1 Section 221.1... MORTGAGE AND LOAN INSURANCE PROGRAMS UNDER NATIONAL HOUSING ACT AND OTHER AUTHORITIES LOW COST AND MODERATE INCOME MORTGAGE INSURANCE-SAVINGS CLAUSE Eligibility Requirements-Low Cost Homes-Savings Clause § 221.1...

  11. Consumer behaviours: Teaching children to save energy

    Science.gov (United States)

    Grønhøj, Alice

    2016-08-01

    Energy-saving programmes are increasingly targeted at children to encourage household energy conservation. A study involving the assignment of energy-saving interventions to Girl Scouts shows that a child-focused intervention can improve energy-saving behaviours among children and their parents.

  12. Costs and longer-term savings of parenting programmes for the prevention of persistent conduct disorder: a modelling study

    Directory of Open Access Journals (Sweden)

    Beecham Jennifer

    2011-10-01

    Full Text Available Abstract Background Conduct disorders are the most common psychiatric disorders in children and may persist into adulthood in about 50% of cases. The costs to society are high and impact many public sector agencies. Parenting programmes have been shown to positively affect child behaviour, but little is known about their potential long-term cost-effectiveness. We therefore estimate the costs of and longer-term savings from evidence-based parenting programmes for the prevention of persistent conduct disorder. Methods A decision-analytic Markov model compares two scenarios: 1 a 5-year old with clinical conduct disorder receives an evidence-based parenting programme; 2 the same 5-year old does not receive the programme. Cost-savings analysis is performed by comparing the probability that conduct disorder persists over time in each scenario, adopting both a public sector and a societal perspective. If the intervention is successful in reducing persistent conduct disorder, cost savings may arise from reduced use of health services, education support, social care, voluntary agencies and from crimes averted. Results Results strongly suggest that parenting programmes reduce the chance that conduct disorder persists into adulthood and are cost-saving to the public sector within 5-8 years under base case conditions. Total savings to society over 25 years are estimated at £16,435 per family, which compares with an intervention cost in the range of £952-£2,078 (2008/09 prices. Conclusions Effective implementation of evidence-based parenting programmes is likely to yield cost savings to the public sector and society. More research is needed to address evidence gaps regarding the current level of provision, longer-term effectiveness and questions of implementation, engagement and equity.

  13. L-cysteine efflux in erythrocytes as a function of human age: correlation with reduced glutathione and total anti-oxidant potential.

    Science.gov (United States)

    Kumar, Prabhanshu; Maurya, Pawan Kumar

    2013-06-01

    Thiol compounds such as cysteine (Cys) and reduced glutathione (GSH) play an important role in human aging and age-related diseases. In erythrocytes, GSH is synthesized by glutamic acid, cysteine, and glycine, but the rate of GSH synthesis is determined only by the availability of L-cysteine. Cysteine supplementation has been shown to ameliorate several parameters that are known to degenerate during human aging. We have studied L-cysteine efflux in vitro in human erythrocytes as a function of age by suspending cells in solution containing 10 mM L-cysteine for uptake; later cells were re-suspended in phosphate-buffered saline (PBS)-glucose to allow efflux. Change in the free sulfhydryl (-SH) concentration was then measured to calculate the rate of efflux. The GSH/oxidized glutathione (GSSG) ratio was taken as a control to study the oxidation/reduction state of the erythrocyte. The total anti-oxidant potential of plasma was measured in terms of ferric reducing ability of plasma (FRAP) values. We have shown a significant (pL-cysteine in erythrocytes during human aging, and the GSH/GSSG ratio decreases as a function of human age. The decline in L-cysteine efflux during aging correlates with the decrease in GSH and the FRAP value. This finding may help to explain the shift in the redox status and low GSH concentration that might determine the rate of L-cysteine efflux observed in erythrocytes and an important factor in the development of oxidative stress in erythrocytes during aging.

  14. Total mercury and methylmercury accumulation in wild plants grown at wastelands composed of mine tailings: Insights into potential candidates for phytoremediation.

    Science.gov (United States)

    Qian, Xiaoli; Wu, Yonggui; Zhou, Hongyun; Xu, Xiaohang; Xu, Zhidong; Shang, Lihai; Qiu, Guangle

    2018-08-01

    Total mercury (THg) and methylmercury (MMHg) were investigated in 259 wild plants belonging to 49 species in 29 families that grew in heavily Hg-contaminated wastelands composed of cinnabar ore mine tailings (calcines) in the Wanshan region, southwestern China, the world's third largest Hg mining district. The bioconcentration factors (BCFs) of THg and MMHg from soil to roots ([THg] root /[THg] soil , [MMHg] root /[MMHg] soil ) were evaluated. The results showed that THg and MMHg in both plants and soils varied widely, with ranges of 0.076-140 μg/g THg and 0.19-87 ng/g MMHg in roots, 0.19-106 μg/g THg and 0.06-31 ng/g MMHg in shoots, and 0.74-1440 μg/g THg and 0.41-820 ng/g MMHg in soil. Among all investigated species, Arthraxon hispidus, Eremochloa ciliaris, Clerodendrum bunge, and Ixeris sonchifolia had significantly elevated concentrations of THg in shoots and/or roots that reached 100 μg/g, whereas Chenopodium glaucum, Corydalisedulis maxim, and Rumex acetosa contained low values below 0.5 μg/g. In addition to the high THg concentrations, the fern E. ciliaris also showed high BCF values for both THg and MMHg exceeding 1.0, suggesting its capability to extract Hg from soils. Considering its dominance and the tolerance identified in the present study, E. ciliaris is suggested to be a practical candidate for phytoextraction, whereas A. hispidus is identified as a potential candidate for phytostabilization of Hg mining-contaminated soils. Copyright © 2018 Elsevier Ltd. All rights reserved.

  15. Determination of the streaming potential and the corresponding total charge in aqueous asphalthene containing suspensions; Bestimmung der Stroemungspotentiale und der korrespondierenden Gesamtladungen in waessrigen, asphaltenhaltigen Suspensionen

    Energy Technology Data Exchange (ETDEWEB)

    Edler, S. [Inst. fuer Erdoel- und Erdgasforschung, Clausthal-Zellerfeld (Germany); Rosenplaenter, A. [Inst. fuer Erdoel- und Erdgasforschung, Clausthal-Zellerfeld (Germany); Rahimian, I. [Inst. fuer Erdoel- und Erdgasforschung, Clausthal-Zellerfeld (Germany)

    1996-02-01

    The choice of demulgators for separating crude oil emulsions is still done empirically. The knowledge of the charge of crude oil compounds is essential for the amount of needed demulsifiers. By using the Particle Charge Detector of the Muetek Company the surface charges of these compounds could be determined. The suspension will be titrated with demulsifier. Surface active compounds ar enriched within the colloids of crude oil, i.e. the resins and the asphaltenes. The asphaltenes could be divided into the easy, medium and difficult soluble asphaltenes. The streaming potential of the colloids and their corresponding total charge could be determined successfully. With increasing quantity of asphaltenes the charge consumption increase almost linearly. The heavy soluble asphaltenes are needing the highest share of demulsifiers followed by the middle and the light soluble asphaltenes. The resins only show very small charge consumption. (orig.) [Deutsch] Die Auswahl von Spaltern zur Trennung von Rohoelemulsionen erfolgt zumeist empirisch. Bei Kenntnis der Ladung der rohoeleigenen Emulgatoren ist eine gezieltere Auswahl der Splater moeglich. Mit Hilfe eines Partikelladungsdetektors sollten die Oberflaechenladungen der rohoeleigenen Emulgatoren bestimmt werden. Dazu wurden Suspensionen der Rohoelkolloide mit Tensid titriert. Grenzflaechenaktive Stoffe sind in den Rohoelkolloiden, also den Erdoelharzen und den Asphaltenen, angereichert. Die Asphaltene lassen sich in leicht-, mittel- und schwerloesliche Komponenten einteilen. Es konnte das Stroemungspotential der Rohoelkolloide und die korrespondierende Gesamtladung erfolgreich bestimmt werden. Mit konstant steigendem Gehalt an Kolloiden steigt auch der Ladungsverbrauch annaehernd linear. Bei den Asphaltenfraktionen verbrauchen die schwerloeslichen Asphaltene mit Abstand den groessten Anteil der Ladung, gefolgt von den mittel- und den leichtloeslichen. Die Erdoelharze zeigen einen sehr geringen Ladungsverbrauch. (orig.)

  16. Energy supply and energy saving in Ukraine

    Directory of Open Access Journals (Sweden)

    V.M. Ilchenko

    2015-09-01

    Full Text Available The article examines the main problems and solutions of energy saving and energy supply in Ukraine. Low energy efficiency has become one of the main factors of the crisis in the Ukrainian economy. The most relevant scientific and methodical approaches to assessment of the level of energy consumption and saving are indicated. The comparative analysis of annual energy use has been made. A potential to solve energy supply problems is strongly correlated with the ability to ensure the innovative development of economy for efficient and economical use of existing and imported energy resources. The ways for reducing of energy resource consumption have been suggested. Creation of technological conditions for the use of alternative energy sources is considered to be rational also. The development of renewable sources of energy (alternative and renewable energy sources will provide a significant effect in reducing the use of traditional energy sources, harmful emissions and greenhouse gas. Under these conditions, increasing of energy efficiency of economy and its competitiveness can be real. Improvement of environmental and social conditions of citizens of the country will mark a positive step towards the EU, and also will cancel some problems of the future generation.

  17. Defining a standard metric for electricity savings

    International Nuclear Information System (INIS)

    Koomey, Jonathan; Akbari, Hashem; Blumstein, Carl; Brown, Marilyn; Brown, Richard; Calwell, Chris; Carter, Sheryl; Cavanagh, Ralph; Chang, Audrey; Claridge, David; Craig, Paul; Diamond, Rick; Eto, Joseph H; Fulkerson, William; Gadgil, Ashok; Geller, Howard; Goldemberg, Jose; Goldman, Chuck; Goldstein, David B; Greenberg, Steve

    2010-01-01

    The growing investment by governments and electric utilities in energy efficiency programs highlights the need for simple tools to help assess and explain the size of the potential resource. One technique that is commonly used in this effort is to characterize electricity savings in terms of avoided power plants, because it is easier for people to visualize a power plant than it is to understand an abstraction such as billions of kilowatt-hours. Unfortunately, there is no standardization around the characteristics of such power plants. In this letter we define parameters for a standard avoided power plant that have physical meaning and intuitive plausibility, for use in back-of-the-envelope calculations. For the prototypical plant this article settles on a 500 MW existing coal plant operating at a 70% capacity factor with 7% T and D losses. Displacing such a plant for one year would save 3 billion kWh/year at the meter and reduce emissions by 3 million metric tons of CO 2 per year. The proposed name for this metric is the Rosenfeld, in keeping with the tradition among scientists of naming units in honor of the person most responsible for the discovery and widespread adoption of the underlying scientific principle in question-Dr Arthur H Rosenfeld.

  18. Defining a standard metric for electricity savings

    Energy Technology Data Exchange (ETDEWEB)

    Koomey, Jonathan [Lawrence Berkeley National Laboratory and Stanford University, PO Box 20313, Oakland, CA 94620-0313 (United States); Akbari, Hashem; Blumstein, Carl; Brown, Marilyn; Brown, Richard; Calwell, Chris; Carter, Sheryl; Cavanagh, Ralph; Chang, Audrey; Claridge, David; Craig, Paul; Diamond, Rick; Eto, Joseph H; Fulkerson, William; Gadgil, Ashok; Geller, Howard; Goldemberg, Jose; Goldman, Chuck; Goldstein, David B; Greenberg, Steve, E-mail: JGKoomey@stanford.ed

    2010-01-15

    The growing investment by governments and electric utilities in energy efficiency programs highlights the need for simple tools to help assess and explain the size of the potential resource. One technique that is commonly used in this effort is to characterize electricity savings in terms of avoided power plants, because it is easier for people to visualize a power plant than it is to understand an abstraction such as billions of kilowatt-hours. Unfortunately, there is no standardization around the characteristics of such power plants. In this letter we define parameters for a standard avoided power plant that have physical meaning and intuitive plausibility, for use in back-of-the-envelope calculations. For the prototypical plant this article settles on a 500 MW existing coal plant operating at a 70% capacity factor with 7% T and D losses. Displacing such a plant for one year would save 3 billion kWh/year at the meter and reduce emissions by 3 million metric tons of CO{sub 2} per year. The proposed name for this metric is the Rosenfeld, in keeping with the tradition among scientists of naming units in honor of the person most responsible for the discovery and widespread adoption of the underlying scientific principle in question-Dr Arthur H Rosenfeld.

  19. Defining a Standard Metric for Electricity Savings

    Energy Technology Data Exchange (ETDEWEB)

    Brown, Marilyn; Akbari, Hashem; Blumstein, Carl; Koomey, Jonathan; Brown, Richard; Calwell, Chris; Carter, Sheryl; Cavanagh, Ralph; Chang, Audrey; Claridge, David; Craig, Paul; Diamond, Rick; Eto, Joseph H.; Fulkerson, William; Gadgil, Ashok; Geller, Howard; Goldemberg, Jose; Goldman, Chuck; Goldstein, David B.; Greenberg, Steve; Hafemeister, David; Harris, Jeff; Harvey, Hal; Heitz, Eric; Hirst, Eric; Hummel, Holmes; Kammen, Dan; Kelly, Henry; Laitner, Skip; Levine, Mark; Lovins, Amory; Masters, Gil; McMahon, James E.; Meier, Alan; Messenger, Michael; Millhone, John; Mills, Evan; Nadel, Steve; Nordman, Bruce; Price, Lynn; Romm, Joe; Ross, Marc; Rufo, Michael; Sathaye, Jayant; Schipper, Lee; Schneider, Stephen H; Sweeney, James L; Verdict, Malcolm; Vorsatz, Diana; Wang, Devra; Weinberg, Carl; Wilk, Richard; Wilson, John; Worrell, Ernst

    2009-03-01

    The growing investment by governments and electric utilities in energy efficiency programs highlights the need for simple tools to help assess and explain the size of the potential resource. One technique that is commonly used in this effort is to characterize electricity savings in terms of avoided power plants, because it is easier for people to visualize a power plant than it is to understand an abstraction such as billions of kilowatt-hours. Unfortunately, there is no standardization around the characteristics of such power plants. In this letter we define parameters for a standard avoided power plant that have physical meaning and intuitive plausibility, for use in back-of-the-envelope calculations. For the prototypical plant this article settles on a 500 MW existing coal plant operating at a 70percent capacity factor with 7percent T&D losses. Displacing such a plant for one year would save 3 billion kW h per year at the meter and reduce emissions by 3 million metric tons of CO2 per year. The proposed name for this metric is the Rosenfeld, in keeping with the tradition among scientists of naming units in honor of the person most responsible for the discovery and widespread adoption of the underlying scientific principle in question--Dr. Arthur H. Rosenfeld.

  20. Annual Energy Savings and Thermal Comfort of Autonomously Heated and Cooled Office Chairs

    Energy Technology Data Exchange (ETDEWEB)

    Carmichael, Scott [National Renewable Energy Lab. (NREL), Golden, CO (United States); Booten, Chuck [National Renewable Energy Lab. (NREL), Golden, CO (United States); Robertson, Joseph [National Renewable Energy Lab. (NREL), Golden, CO (United States); Chin, Justin [National Renewable Energy Lab. (NREL), Golden, CO (United States); Christensen, Dane [National Renewable Energy Lab. (NREL), Golden, CO (United States); Pless, Jacquelyn [National Renewable Energy Lab. (NREL), Golden, CO (United States); Arent, Doug [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2016-07-01

    Energy use in offices buildings is largely driven by air conditioning demands. But the optimal temperature is not the same for all building occupants, leading to the infamous thermostat war. And many occupants have independently overcome building comfort weaknesses with their own space heaters or fans. NREL tested is a customized office chair that automatically heats and cools the occupant along the seat and chair back according to the occupants' personal preferences. This product is shown to deliver markedly better comfort at room temperatures well above typical office cooling setpoints. Experimental subjects reported satisfaction in these elevated air temperatures, partly because the chair's cooling effect was tuned to their own individual needs. Simulation of the chair in office buildings around the U.S. shows that energy can be saved everywhere, with impacts varying due to the climate. Total building HVAC energy savings exceeded 10% in hot-dry climate zones. Due to high product cost, simple payback for the chair we studied is beyond the expected chair life. We then understood the need to establish cost-performance targets for comfort delivery packages. NREL derived several hypothetical energy/cost/comfort targets for personal comfort product systems. In some climate regions around the U.S., these show the potential for office building HVAC energy savings in excess of 20%. This report documents this research, providing an overview of the research team's methods and results while also identifying areas for future research building upon the findings.

  1. Energy Efficiency Improvement and Cost Saving Oportunities for the Concrete Industry

    Energy Technology Data Exchange (ETDEWEB)

    Kermeli, Katerina; Worrell, Ernst; Masanet, Eric

    2011-12-01

    The U.S. concrete industry is the main consumer of U.S.-produced cement. The manufacturing of ready mixed concrete accounts for more than 75% of the U.S. concrete production following the manufacturing of precast concrete and masonry units. The most significant expenditure is the cost of materials accounting for more than 50% of total concrete production costs - cement only accounts for nearly 24%. In 2009, energy costs of the U.S. concrete industry were over $610 million. Hence, energy efficiency improvements along with efficient use of materials without negatively affecting product quality and yield, especially in times of increased fuel and material costs, can significantly reduce production costs and increase competitiveness. The Energy Guide starts with an overview of the U.S. concrete industry’s structure and energy use, a description of the various manufacturing processes, and identification of the major energy consuming areas in the different industry segments. This is followed by a description of general and process related energy- and cost-efficiency measures applicable to the concrete industry. Specific energy and cost savings and a typical payback period are included based on literature and case studies, when available. The Energy Guide intends to provide information on cost reduction opportunities to energy and plant managers in the U.S. concrete industry. Every cost saving opportunity should be assessed carefully prior to implementation in individual plants, as the economics and the potential energy and material savings may differ.

  2. Dividing wall column: Improving thermal efficiency, energy savings and economic performance

    International Nuclear Information System (INIS)

    Aurangzeb, Md; Jana, Amiya K.

    2016-01-01

    Highlights: • A rigorous model is developed for a dividing wall column. • Heat transfer model for metal wall is proposed. • Performance improvement is quantified for a ternary system. • Thermal efficiency, energy savings and cost are three used indices. - Abstract: This work aims at investigating the performance improvement of a dividing wall column (DWC) for the separation of a ternary system. It is true that for fractionating a ternary mixture, at least a sequence of two conventional distillation columns is required. To improve energetic and economic potential, and reduce space requirement, two columns are proposed to merge into one shell with a dividing wall. For developing the mathematical model of a distillation column, we consider the effect of heat transfer through the metal wall placed at an intermediated position inside the cylindrical column. The simulated DWC model is verified using the Aspen Plus flowsheet simulator with a wide variety of phase equilibrium models. The superiority of this proposed heat integrated configuration is shown for a ternary hydrocarbon system over a conventional distillation sequence (CDS) in terms of mainly three performance indexes, namely thermal efficiency, energy savings and total annual cost (TAC). It is investigated that the dividing wall distillation scheme can secure a 37.5% energy efficiency, and a 22.6% savings in energy consumption and 23.23% in TAC. The promising performance can also be quantified in terms of a reasonably low payback period of 2.11 years.

  3. Energy and water saving measures at the Arloev sugar mill. Final report; Energi- och vattenbesparande aatgaerder vid Arloevs Sockerbruk. Slutrapport

    Energy Technology Data Exchange (ETDEWEB)

    Wamsler, M. [AAF-Processdesign AB, Malmoe (Sweden)

    2001-10-01

    The project comprised several, mutually dependent, sub-projects; mapping, investigation of ways to reduce water consumption, membrane tests aiming to find ways to recover sugar, and pinch analysis to evaluate the possibilities for improved process integration. This final report deals with the overall project results. Identified savings opportunities and savings potentials are presented. The presented measures represent an overall optimisation based on the results of all the project parts. Already during the project, measures have been implemented that are calculated to save 65 000 m{sup 3} water annually, corresponding to 10 % of the total water consumption. This saving is in level with the goals for the project. In the table below, these and additional measures are presented with a total savings potential at approximately 200 000 m{sup 3} /year water. The project will then achieve a saving of just below 35 % of present water consumption. Also in the membrane study the results surpassed the expectations. It was found that with nano filtering a sugar concentration of more than 10 %(W) could be reached in the retentate at a flux 50al/m{sup 2}h. The total sugar losses were less than 5 %, i.e. 95 % should be possible to recover. In total, a savings potential of more than 300 tonnes sugar per year is indicated. The Energy savings in the project are calculated to 7,4 GWh/year, of which 0,2 GWh/year by reduced water consumption, 0,6 GWh/year by water recovery, 1,4 GWh/year by membrane technology and 5,2aGWh/year as a result of process integration. This should be compared to the target 2,5 GWh/year. Hence, the results are almost three times the expected. The savings in monetary terms are estimated at just under SEK 5 million per year. The investment is roughly estimated at between SEK 5 and 6 million, of which SEK 4 million for the membrane equipment and SEK 0,5 million for a process water buffer tank. The remaining investment costs cover heat exchangers, control equipment

  4. SWEEP - Save Water & Energy Education Program

    Energy Technology Data Exchange (ETDEWEB)

    Sullivan, Gregory P.; Elliott, Douglas B.; Hillman, Tim C.; Hadley, Adam; Ledbetter, Marc R.; Payson, David R.

    2001-05-03

    The objective of this study was to develop, monitor, analyze, and report on an integrated resource-conservation program highlighting efficient residential appliances and fixtures. The sites of study were 50 homes in two water-constrained communities located in Oregon. The program was designed to maximize water savings to these communities and to serve as a model for other communities seeking an integrated approach to energy and water resource efficiency. The program included the installation and in-place evaluation of energy- and water-efficient devices including the following: horizontal axis clothes washers (and the matching clothes dryers), resource-efficient dishwashers, an innovative dual flush low-flow toilet, low-flow showerheads, and faucet aerators. The significance of this activity lies in its integrated approach and unique metering evaluation of individual end-use, aggregated residential total use, and system-wide energy and water benefits.

  5. Energy saving consulting in Hamburg

    Energy Technology Data Exchange (ETDEWEB)

    1982-10-01

    For anyone who wants to realise the dream of his own house, the terms of thermal insulation and saving heating plant should be central in planning this. One needs advice from experts for this. A survey of the many consultants offices available in Hamburg is provided. The list was compiled with the assistance of the Hamburg Chamber of Commerce and the Hamburg Trades Council and of professional associations. The information on the special fields of activity of the named consultants is based on their statements.

  6. Medical savings accounts make waves.

    Science.gov (United States)

    Gardner, J

    1995-02-27

    MSAs: the theory. Medical savings account legislation would allow consumers to set aside pre-tax dollars to pay for day-to-day healthcare costs. The accounts are to be backed up by a catastropic policy with a deductible roughly equal to the maximum amount allowed in the MSA. The aim is to reduce healthcare cost inflation by making consumers more aware of the costs of healthcare than they are under comprehensive policies and enabling them to shop for the lowest-cost, highest-quality care.

  7. Student saving, does it exist? : A study of students' saving behavior, attitude towards saving and motivation to save.

    OpenAIRE

    Tuvesson, Joakim; Yu, Shiyu

    2011-01-01

    Swedish households are getting deeper in debt and house prices keeps on rising. This is what happened in USA and it was one of the major causes of the recent financial crisis. To avoid a similar crisis in Sweden we think one part of the solution is to make sure that those who are students today and soon will get jobs, buy houses, take loans etcetera have necessary knowledge to do so. Students’ saving is an area that almost completely lacked researchers’ attention, and one goal with this thesi...

  8. Value of travel time savings

    DEFF Research Database (Denmark)

    Le Masurier, P.; Polak, J.; Pawlak, Janet

    2015-01-01

    A team of specialist market researchers and Value of Time experts comprising members from SYSTRA, Imperial College London and the Technical University of Denmark has conducted a formal audit and peer review of research undertaken by Arup/ITS Leeds/Accent to derive Value of Travel Time Savings...... Preference (RP) models that were used to derive final Values of Travel Time (VTT). This report contains the findings of our audit and peer review of the procedures adopted by the research team during data collection of the three surveys (SP, RP and Employers Surveys); a peer review of the reported approach...

  9. LED Lightbulbs as a Source of Electricity Saving in Buildings

    Directory of Open Access Journals (Sweden)

    Zeb Akhtar

    2016-01-01

    Full Text Available Today a number of renewable energy technologies are available for power generation, but fossil fuels are still providing a dominant share nevertheless. In order to decrease the electric bill and save our environment, energy conservation is always crucial. In this paper a very interesting idea is presented which is economically viable to reduce electricity usage in our buildings. An effort has been made to estimate the amount of energy that could be saved in the dormitory section of the IMOP building in Russia. Although there are many ways to reduce the consumption of electricity in this building but here the emphasis is on changing light bulbs inside the rooms, kitchen, toilet and bathroom of each apartment. The scope of the study is to figure out monthly electricity saving by replacing traditional light bulbs by LED light bulbs in the building under consideration. The total investment required and the payback period is also presented.

  10. Connecting possibilistic prudence and optimal saving

    Directory of Open Access Journals (Sweden)

    Ana María Lucia Casademunt

    2013-12-01

    Full Text Available In this paper we study the optimal saving problem in the framework of possibility theory. The notion of possibilistic precautionary saving is introduced as a measure of the way the presence of possibilistic risk (represented by a fuzzy number influences a consumer in establishing the level of optimal saving. The notion of prudence of an agent in the face of possibilistic risk is defined and the equivalence between the prudence condition and a positive possibilistic precautionary saving is proved. Some relations between possibilistic risk aversion, prudence and possibilistic precautionary saving were established.

  11. Energy Savings Measure Packages. Existing Homes

    Energy Technology Data Exchange (ETDEWEB)

    Casey, Sean [National Renewable Energy Lab. (NREL), Golden, CO (United States); Booten, Chuck [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2011-11-01

    This document presents the most cost effective Energy Savings Measure Packages (ESMP) for existing mixed-fuel and all electric homes to achieve 15% and 30% savings for each BetterBuildings grantee location across the United States. These packages are optimized for minimum cost to homeowners for source energy savings given the local climate and prevalent building characteristics (i.e. foundation types). Maximum cost savings are typically found between 30% and 50% energy savings over the reference home; this typically amounts to $300 - $700/year.

  12. The Three R's of Utility Savings: Rate Reduction, Rebates and Retrofit.

    Science.gov (United States)

    Petiunas, Raymond V.

    1993-01-01

    An effective way to increase electricity energy savings for school districts is to integrate rate case participation (rate reduction) with conservation and load-management efforts (rebates) and retrofit operations, to obtain a total energy cost reduction package. Describes how a Pennsylvania consortium of school districts saved its member…

  13. Strategies for reducing implant costs in the revision total knee arthroplasty episode of care.

    Science.gov (United States)

    Elbuluk, Ameer M; Old, Andrew B; Bosco, Joseph A; Schwarzkopf, Ran; Iorio, Richard

    2017-12-01

    Implant price has been identified as a significant contributing factor to high costs associated with revision total knee arthroplasty (rTKA). The goal of this study is to analyze the cost of implants used in rTKAs and to compare this pricing with 2 alternative pricing models. Using our institutional database, we identified 52 patients from January 1, 2014 to December 31, 2014. Average cost of components for each case was calculated and compared to the total hospital cost for that admission. Costs for an all-component revision were then compared to a proposed "direct to hospital" (DTH) standardized pricing model and a fixed price revision option. Potential savings were calculated from these figures. On average, 28% of the total hospital cost was spent on implants for rTKA. The average cost for revision of all components was $13,640 and ranged from $3000 to $28,000. On average, this represented 32.7% of the total hospital cost. Direct to hospital implant pricing could potentially save approximately $7000 per rTKA, and the fixed pricing model could provide a further $1000 reduction per rTKA-potentially saving $8000 per case on implants alone. Alternative implant pricing models could help lower the total cost of rTKA, which would allow hospitals to achieve significant cost containment.

  14. Totally James

    Science.gov (United States)

    Owens, Tom

    2006-01-01

    This article presents an interview with James Howe, author of "The Misfits" and "Totally Joe". In this interview, Howe discusses tolerance, diversity and the parallels between his own life and his literature. Howe's four books in addition to "The Misfits" and "Totally Joe" and his list of recommended books with lesbian, gay, bisexual, transgender,…

  15. Missouri Agricultural Energy Saving Team-A Revolutionary Opportunity (MAESTRO)

    Energy Technology Data Exchange (ETDEWEB)

    McIntosh, Jane [MDA; Schumacher, Leon [University of Missouri

    2014-10-23

    The Missouri Agricultural Energy Saving Team-A Revolutionary Opportunity (MAESTRO) program brought together a team of representatives from government, academia, and private industry to enhance the availability of energy efficiency services for small livestock producers in the State of Missouri. The Missouri Department of Agriculture (MDA) managed the project via a subcontract with the University of Missouri (MU), College of Agriculture Food and Natural Resources, MU Extension, the MU College of Human Environmental Sciences, the MU College of Engineering, and the Missouri Agricultural and Small Business Development Authority (MASBDA). MU teamed with EnSave, Inc, a nationally-recognized expert in agricultural energy efficiency to assist with marketing, outreach, provision of farm energy audits and customer service. MU also teamed with independent home contractors to facilitate energy audits of the farm buildings and homes of these livestock producers. The goals of the project were to: (1) improve the environment by reducing fossil fuel emissions and reducing the total energy used on small animal farms; (2) stimulate the economy of local and regional communities by creating or retaining jobs; and (3) improve the profitability of Missouri livestock producers by reducing their energy expenditures. Historically, Missouri scientists/engineers conducted programs on energy use in agriculture, such as in equipment, grain handling and tillage practices. The MAESTRO program was the first to focus strictly on energy efficiency associated with livestock production systems in Missouri and to investigate the applicability and potential of addressing energy efficiency in animal production from a building efficiency perspective. A. Project Objectives The goal of the MAESTRO program was to strengthen the financial viability and environmental soundness of Missouri's small animal farms by helping them implement energy efficient technologies for the production facility, farm

  16. Do Tax Incentives for Saving in Pension Accounts Cause Debt Accumulation?

    DEFF Research Database (Denmark)

    Yde Andersen, Henrik

    Measuring the effect of an unanticipated reduction in tax credits on pension savings, this paper shows that individuals tend to make extraordinary repayments on their debt when saving in retirement accounts becomes less attractive. We conclude that tax-favoured retirement accounts could affect...... gross debt accumulation. In line with recent studies, we show that tax subsidies for saving in pension accounts only affect total individual savings to a limited extent, but unlike prior research this paper distinguishes between the effects on financial assets and liabilities. As a particular feature...

  17. Energy-saving strategies with personalized ventilation in cold climates

    DEFF Research Database (Denmark)

    Shiavon, Stefano; Melikov, Arsen Krikor

    2009-01-01

    In this study the influence of the personalized supply air temperature control strategy on energy consumption and the energy-saving potentials of a personalized ventilation system have been investigated by means of simulations with IDA-ICE software. GenOpt software was used to determine the optimal...

  18. Risks versus savings in the international spot market

    International Nuclear Information System (INIS)

    Karalus, J.L.

    1988-01-01

    This paper describes the international spot market, some of its risks and difficulties, and examples of the ways potential savings can be realized. Fuel cycle goods and services available in the international spot market include uranium as U 3 O 8 , natural UF 6 , enriched UF 6 , conversion services, and enriching services

  19. Evalutation of retrofitting strategies for energy savings in Brazilian hotels

    NARCIS (Netherlands)

    Cademartori, E.; Mutani, G.; Costola, D.; Hensen, J.L.M.

    2012-01-01

    ABSTRACT. A strong increase of hospitality infrastructure is taking place in Brazil due to imminent international events. In order to understand energy saving potential of this sector, an existing business hotel in Goiania, a mid-western Brazilian metropolis, was analyzed as case study taking into

  20. Federal Aviation Administration retained savings program proposal

    International Nuclear Information System (INIS)

    Hostick, D.J.; Larson, L.L.; Hostick, C.J.

    1998-03-01

    Federal legislation allows federal agencies to retain up to 50% of the savings associated with implementing energy efficiency and water conservation measures and practices. Given budget pressures to reduce expenditures, the use of retained savings to fund additional projects represents a source of funds outside of the traditional budget cycle. The Southwest Region Federal Aviation Administration (FAA) has tasked Pacific Northwest National Laboratory (PNNL) to develop a model retained savings program for Southwest Region FAA use and as a prototype for consideration by the FAA. PNNL recommends the following steps be taken in developing a Southwest Region FAA retained savings program: Establish a retained savings mechanism. Determine the level at which the retained savings should be consolidated into a fund. The preliminary recommendation is to establish a revolving efficiency loan fund at the regional level. Such a mechanism allows some consolidation of savings to fund larger projects, while maintaining a sense of facility ownership in that the funds will remain within the region

  1. Energy saving synergies in national energy systems

    DEFF Research Database (Denmark)

    Thellufsen, Jakob Zinck; Lund, Henrik

    2015-01-01

    In the transition towards a 100% renewable energy system, energy savings are essential. The possibility of energy savings through conservation or efficiency increases can be identified in, for instance, the heating and electricity sectors, in industry, and in transport. Several studies point...... to various optimal levels of savings in the different sectors of the energy system. However, these studies do not investigate the idea of energy savings being system dependent. This paper argues that such system dependency is critical to understand, as it does not make sense to analyse an energy saving...... without taking into account the actual benefit of the saving in relation to the energy system. The study therefore identifies a need to understand how saving methods may interact with each other and the system in which they are conducted. By using energy system analysis to do hourly simulation...

  2. Saving in cycles: how to get people to save more money.

    Science.gov (United States)

    Tam, Leona; Dholakia, Utpal

    2014-02-01

    Low personal savings rates are an important social issue in the United States. We propose and test one particular method to get people to save more money that is based on the cyclical time orientation. In contrast to conventional, popular methods that encourage individuals to ignore past mistakes, focus on the future, and set goals to save money, our proposed method frames the savings task in cyclical terms, emphasizing the present. Across the studies, individuals who used our proposed cyclical savings method, compared with individuals who used a linear savings method, provided an average of 74% higher savings estimates and saved an average of 78% more money. We also found that the cyclical savings method was more efficacious because it increased implementation planning and lowered future optimism regarding saving money.

  3. SAVE ENERGY IN TEXTILE SMES

    Directory of Open Access Journals (Sweden)

    SCALIA Mauro

    2016-05-01

    Full Text Available Efficiency and competitiveness in textile and clothing manufacturing sector must take into account the current and future energy challenges. Energy efficiency is a subject of critical importance for the Textile & Clothing industry, for other sectors and for the society in general. EURATEX has initiated Energy Made-to-Measure, an information campaign running until 2016 to empower over 300 textile & clothing companies, notably SMEs, to become more energy efficient. SET( Save Energy in Textile SMEs a collaborative project co-funded within the European Programme Intelligent Energy Europe II helps companies to understand their energy consumption and allows them to compare the sector benchmarks in different production processes. SET has developed the SET tool, Energy Saving and Efficiency Tool, a free of charge tool customized for textile manufacturers. The SET tool is made up of 4 elements: a stand-alone software (SET Tool for self-assessment based on an Excel application; an on-line part (SET tool Web for advanced benchmarking and comparison of the performances across years; a guiding document for the companies and overview of financial incentives and legal obligations regarding energy efficiency. Designed specifically for small and medium enterprises (SMEs, the SET tool enables the evaluation of energy consumption and recommends measures to reduce the consumption. Prior to modifying the company’s production processes and making investments to increase energy efficiency, textile SMEs need to get different type of information, including legal context, economic and technical peculiarities.

  4. A comparative analysis of the epidemiological impact and disease cost-savings of HPV vaccines in France

    Science.gov (United States)

    Bresse, Xavier; Adam, Marjorie; Largeron, Nathalie; Roze, Stephane; Marty, Remi

    2013-01-01

    The aim was to compare the epidemiological and economic impact of 16/18 bivalent and 6/11/16/18 quadrivalent HPV vaccination in France, considering differences in licensed outcomes, protection against non-vaccine HPV types and prevention of HPV-6/11-related diseases. The differential impact of the two vaccines was evaluated using a published model adapted to the French setting. The target population was females aged 14–23 y and the time horizon was 100 y. A total of eight different scenarios compared vaccination impact in terms of reduction in HPV-16/18-associated carcinomas (cervical, vulvar, vaginal, anal, penile and head and neck), HPV-6/11-related genital warts and recurrent respiratory papillomatosis, and incremental reduction in cervical cancer due to potential cross-protection. Quadrivalent vaccine was associated with total discounted cost savings ranging from EUR 544–1,020 million vs. EUR 177–538 million with the bivalent vaccination (100-y time horizon). Genital wart prevention thanks to quadrivalent HPV vaccination accounted for EUR 306–380 million savings (37–56% of costs saved). In contrast, the maximal assumed cross-protection against cervical cancer resulted in EUR 13–33 million savings (4%). Prevention of vulvar, vaginal and anal cancers accounted for additional EUR 71–89 million savings (13%). In France, the quadrivalent HPV vaccination would result in significant incremental epidemiological and economic benefits vs. the bivalent vaccination, driven primarily by prevention of genital. The present analysis is the first in the French setting to consider the impact of HPV vaccination on all HPV diseases and non-vaccine types. PMID:23563511

  5. Recording and Audit of Resource Saving Innovations at Modern Industrial Companies

    Directory of Open Access Journals (Sweden)

    I. M.

    2017-05-01

    Full Text Available Resource saving and energy saving are essential components of “energy security” problem in all the countries, which raises the importance of analysis and revision of approaches to organization of recording and audit of resource saving innovations at industrial companies. The article’s objective is to study organization of recording and audit of resource saving technologies at industrial companies. A review of resource saving purposes and methods is given. For accounting purposes, innovations in resource saving are recorded now as intangible assets. Recording of resource saving innovations and technologies at industrial companies is confined to recording of transactions on creation or acquisition of patent rights objects and intellectual property objects. The author’s approach to organization of audit by the conformity of resource saving innovations with M. Porter’s test is proposed. Data showing success story of a Ukrainian company manufacturing polyurethane foam sealant PENADO in the aerosol dispenser is used to confirm that Ukraine does have potentials to introduce and utilize resource saving technologies, including energy saving ones. The proposed model for recording and audit of resource saving innovations should be used in strategic planning of resource saving innovations at the companies incorporated in industrial groups or holdings. Using this model, a company can reveal and assess the mismatch between amounts of resources that can be allocated in innovation and real capacities for introducing innovative resource saving technologies, and factors having the strongest impact on recourse saving innovations at companies incorporated in one financial and industrial group or holding. The proposed model accounts for the specific operative conditions in holdings and tough conditions for business operation of industrial companies in Ukraine.

  6. Carbon savings resulting from the cooling effect of green areas: A case study in Beijing

    International Nuclear Information System (INIS)

    Lin Wenqi; Wu Tinghai; Zhang Chengguo; Yu Ting

    2011-01-01

    Green areas cool the climate of a city, reduce the energy consumption caused by the urban heat island (UHI) effect, and bring along carbon savings. However, the calculation of carbon savings due to the cooling effect of green areas is still not well understood. We have used a Landsat Enhanced Thematic Mapper Plus (ETM+) image of Beijing, to identify the cooled areas, compute the possible energy used to maintain the temperature differences between cooled areas and their surrounding heated areas, and calculate the carbon savings owing to the avoidance of energy use. Results show that a total amount of 14315.37 tons carbon savings was achieved in the study area and the amount was related to the biomass, the size and the shape of green areas. These results demonstrate the importance of carbon savings resulting from green areas' cooling effect. - Highlights: → We provide an integral equation for the calculation of energy conservation and carbon savings. → We show that carbon savings is partly influenced by green areas' features. → A strong correlation between biomass, size and shape of green areas and carbon savings. - An integral equation for the calculation of energy conservation and carbon savings; Showing that carbon savings is partly influenced by green areas' features.

  7. VO2 thermochromic smart window for energy savings and generation

    Science.gov (United States)

    Zhou, Jiadong; Gao, Yanfeng; Zhang, Zongtao; Luo, Hongjie; Cao, Chuanxiang; Chen, Zhang; Dai, Lei; Liu, Xinling

    2013-10-01

    The ability to achieve energy saving in architectures and optimal solar energy utilisation affects the sustainable development of the human race. Traditional smart windows and solar cells cannot be combined into one device for energy saving and electricity generation. A VO2 film can respond to the environmental temperature to intelligently regulate infrared transmittance while maintaining visible transparency, and can be applied as a thermochromic smart window. Herein, we report for the first time a novel VO2-based smart window that partially utilises light scattering to solar cells around the glass panel for electricity generation. This smart window combines energy-saving and generation in one device, and offers potential to intelligently regulate and utilise solar radiation in an efficient manner.

  8. A multifunctional energy-saving magnetic field generator

    Science.gov (United States)

    Xiong, Hui; Sun, Wanpeng; Liu, Jinzhen; Shi, Jinhua

    2018-03-01

    To improve the energy utilization of magnetic field generators for biological applications, a multifunctional energy-saving magnetic field generator (ESMFG) is presented. It is capable of producing both an alternating magnetic field (AMF) and a bipolar pulse magnetic field (BPMF) with high energy-saving and energy-reuse rates. Based on a theoretical analysis of an RLC second-order circuit, the energy-saving and energy-reuse rates of both types of magnetic fields can be calculated and are found to have acceptable values. The results of an experimental study using the proposed generator show that for the BPMF, the peak current reaches 130 A and the intensity reaches 70.3 mT. For the AMF, the intensity is 11.0 mT and the RMS current is 20 A. The energy-saving and energy-reuse rates for the AMF generator are 61.3% and 63.5%, respectively, while for the BPMF generator, the energy-saving rate is 33.6%. Thus, the proposed ESMFG has excellent potential for use in biomedical applications.

  9. Energy saving behaviours: Development of a practice-based model

    International Nuclear Information System (INIS)

    Sweeney, Jillian C.; Kresling, Johannes; Webb, Dave; Soutar, Geoffrey N.; Mazzarol, Tim

    2013-01-01

    Financial pressure and concern for the environment has meant many consumers are aware of the need to reduce their consumption of many resources, including energy, which is the focus of the present study. While potential energy use deterrents in the form of access constraints and price increases are forms of extrinsic control, it is not clear how effective these are at reducing consumption and, indeed, it is not clear if such measures are consistent with people's underlying energy saving motivations. Beyond behavioural motivations, people's desires to reduce energy can be thwarted (barriers) and/or supported by a variety of factors, some within their control, while others are perhaps less so. Using a practice-based framework and a qualitative focus group approach, this study presents an exploratory study of these issues. Policy suggestions for overcoming barriers, as well suggestions as to how energy saving behaviours can be supported are offered. - Highlights: • We obtained consumers views about energy saving motivations, barriers and support. • Attitudes towards energy saving are not sufficient to change behaviours. • A practice-based approach to understanding energy saving behaviours is applied. • A practice-based energy-cultures framework (PBECF) is developed. • Barriers and support factors are identified that can be conceptualised within a PBECF

  10. Impact of Extended Daylight Saving Time on National Energy Consumption Report to Congress

    Energy Technology Data Exchange (ETDEWEB)

    Belzer, D. B.; Hadley, S. W.; Chin, S-M.

    2008-10-01

    The Energy Policy Act of 2005 (Pub. L. No. 109-58; EPAct 2005) amended the Uniform Time Act of 1966 (Pub. L. No. 89-387) to increase the portion of the year that is subject to Daylight Saving Time. (15 U.S.C. 260a note) EPAct 2005 extended the duration of Daylight Saving Time in the spring by changing its start date from the first Sunday in April to the second Sunday in March, and in the fall by changing its end date from the last Sunday in October to the first Sunday in November. (15 U.S.C. 260a note) EPAct 2005 also called for the Department of Energy to evaluate the impact of Extended Daylight Saving Time on energy consumption in the United States and to submit a report to Congress. (15 U.S.C. 260a note) This report presents the results of impacts of Extended Daylight Saving Time on the national energy consumption in the United States. The key findings are: (1) The total electricity savings of Extended Daylight Saving Time were about 1.3 Tera Watt-hour (TWh). This corresponds to 0.5 percent per each day of Extended Daylight Saving Time, or 0.03 percent of electricity consumption over the year. In reference, the total 2007 electricity consumption in the United States was 3,900 TWh. (2) In terms of national primary energy consumption, the electricity savings translate to a reduction of 17 Trillion Btu (TBtu) over the spring and fall Extended Daylight Saving Time periods, or roughly 0.02 percent of total U.S. energy consumption during 2007 of 101,000 TBtu. (3) During Extended Daylight Saving Time, electricity savings generally occurred over a three- to five-hour period in the evening with small increases in usage during the early-morning hours. On a daily percentage basis, electricity savings were slightly greater during the March (spring) extension of Extended Daylight Saving Time than the November (fall) extension. On a regional basis, some southern portions of the United States exhibited slightly smaller impacts of Extended Daylight Saving Time on energy savings

  11. Savings and Debts in Agriculture

    Directory of Open Access Journals (Sweden)

    Marina Luminita Sarbovan

    2012-05-01

    Full Text Available The savings and debts problematic bring us in front the Keynesian principles of supporting the global demand, so spectacular immortalized inside his “General Theory of Money. The architects of the European Union consider that production in agriculture and other economic branches is “ab initio” grounded on the credit mechanism administrated by banks: the present day approach of the agricultural process configured it as costly, owing a relatively medium to long term duration, and risky, making important the banking institution for miti