WorldWideScience

Sample records for total noise levels

  1. Annoyance from Road Traffic, Trains, Airplanes and from Total Environmental Noise Levels.

    Science.gov (United States)

    Ragettli, Martina S; Goudreau, Sophie; Plante, Céline; Perron, Stéphane; Fournier, Michel; Smargiassi, Audrey

    2015-12-29

    There is a lack of studies assessing the exposure-response relationship between transportation noise and annoyance in North America. Our aims were to investigate the prevalence of noise annoyance induced by road traffic, trains and airplanes in relation to distance to transportation noise sources, and to total environmental noise levels in Montreal, Canada; annoyance was assessed as noise-induced disturbance. A telephone-based survey among 4336 persons aged >18 years was conducted. Exposure to total environmental noise (A-weighted outdoor noise levels-LAeq24h and day-evening-night equivalent noise levels-Lden) for each study participant was determined using a statistical noise model (land use regression-LUR) that is based on actual outdoor noise measurements. The proportion of the population annoyed by road traffic, airplane and train noise was 20.1%, 13.0% and 6.1%, respectively. As the distance to major roads, railways and the Montreal International Airport increased, the percentage of people disturbed and highly disturbed due to the corresponding traffic noise significantly decreased. When applying the statistical noise model we found a relationship between noise levels and disturbance from road traffic and total environmental noise, with Prevalence Proportion Ratios (PPR) for highly disturbed people of 1.10 (95% CI: 1.07-1.13) and 1.04 (1.02-1.06) per 1 dB(A) Lden, respectively. Our study provides the first comprehensive information on the relationship between transportation noise levels and disturbance in a Canadian city. LUR models are still in development and further studies on transportation noise induced annoyance are consequently needed, especially for sources other than road traffic.

  2. Annoyance from Road Traffic, Trains, Airplanes and from Total Environmental Noise Levels

    Directory of Open Access Journals (Sweden)

    Martina S. Ragettli

    2015-12-01

    Full Text Available There is a lack of studies assessing the exposure-response relationship between transportation noise and annoyance in North America. Our aims were to investigate the prevalence of noise annoyance induced by road traffic, trains and airplanes in relation to distance to transportation noise sources, and to total environmental noise levels in Montreal, Canada; annoyance was assessed as noise-induced disturbance. A telephone-based survey among 4336 persons aged >18 years was conducted. Exposure to total environmental noise (A-weighted outdoor noise levels—LAeq24h and day-evening-night equivalent noise levels—Lden for each study participant was determined using a statistical noise model (land use regression—LUR that is based on actual outdoor noise measurements. The proportion of the population annoyed by road traffic, airplane and train noise was 20.1%, 13.0% and 6.1%, respectively. As the distance to major roads, railways and the Montreal International Airport increased, the percentage of people disturbed and highly disturbed due to the corresponding traffic noise significantly decreased. When applying the statistical noise model we found a relationship between noise levels and disturbance from road traffic and total environmental noise, with Prevalence Proportion Ratios (PPR for highly disturbed people of 1.10 (95% CI: 1.07–1.13 and 1.04 (1.02–1.06 per 1 dB(A Lden, respectively. Our study provides the first comprehensive information on the relationship between transportation noise levels and disturbance in a Canadian city. LUR models are still in development and further studies on transportation noise induced annoyance are consequently needed, especially for sources other than road traffic.

  3. Annoyance from Road Traffic, Trains, Airplanes and from Total Environmental Noise Levels

    Science.gov (United States)

    Ragettli, Martina S.; Goudreau, Sophie; Plante, Céline; Perron, Stéphane; Fournier, Michel; Smargiassi, Audrey

    2015-01-01

    There is a lack of studies assessing the exposure-response relationship between transportation noise and annoyance in North America. Our aims were to investigate the prevalence of noise annoyance induced by road traffic, trains and airplanes in relation to distance to transportation noise sources, and to total environmental noise levels in Montreal, Canada; annoyance was assessed as noise-induced disturbance. A telephone-based survey among 4336 persons aged >18 years was conducted. Exposure to total environmental noise (A-weighted outdoor noise levels—LAeq24h and day-evening-night equivalent noise levels—Lden) for each study participant was determined using a statistical noise model (land use regression—LUR) that is based on actual outdoor noise measurements. The proportion of the population annoyed by road traffic, airplane and train noise was 20.1%, 13.0% and 6.1%, respectively. As the distance to major roads, railways and the Montreal International Airport increased, the percentage of people disturbed and highly disturbed due to the corresponding traffic noise significantly decreased. When applying the statistical noise model we found a relationship between noise levels and disturbance from road traffic and total environmental noise, with Prevalence Proportion Ratios (PPR) for highly disturbed people of 1.10 (95% CI: 1.07–1.13) and 1.04 (1.02–1.06) per 1 dB(A) Lden, respectively. Our study provides the first comprehensive information on the relationship between transportation noise levels and disturbance in a Canadian city. LUR models are still in development and further studies on transportation noise induced annoyance are consequently needed, especially for sources other than road traffic. PMID:26729143

  4. Effects of background noise on total noise annoyance

    Science.gov (United States)

    Willshire, K. F.

    1987-01-01

    Two experiments were conducted to assess the effects of combined community noise sources on annoyance. The first experiment baseline relationships between annoyance and noise level for three community noise sources (jet aircraft flyovers, traffic and air conditioners) presented individually. Forty eight subjects evaluated the annoyance of each noise source presented at four different noise levels. Results indicated the slope of the linear relationship between annoyance and noise level for the traffic noise was significantly different from that of aircraft and of air conditioner noise, which had equal slopes. The second experiment investigated annoyance response to combined noise sources, with aircraft noise defined as the major noise source and traffic and air conditioner noise as background noise sources. Effects on annoyance of noise level differences between aircraft and background noise for three total noise levels and for both background noise sources were determined. A total of 216 subjects were required to make either total or source specific annoyance judgements, or a combination of the two, for a wide range of combined noise conditions.

  5. Ionizing Radiation Effects on the Noise of 65 nm CMOS Transistors for Pixel Sensor Readout at Extreme Total Dose Levels

    CERN Document Server

    Re, V.; Manghisoni, M.; Riceputi, E.; Traversi, G.; Ratti, L.

    2018-01-01

    This paper is focused on the study of the noise performance of 65 nm CMOS transistors at extremely high total ionizing dose (TID) levels of the order of several hundreds of Mrad(SiO2). Noise measurements are reported and discussed, analyzing radiation effects on 1/ f noise and channel thermal noise. In nMOSFETs, up to 10 Mrad(SiO2), the experimental behavior is consistent with a damage mechanism mainly associ- ated with lateral isolation oxides, and can be modeled by parasitic transistors turning on after irradiation and contributing to the total noise of the device. At very high dose, these parasitic transistors tend to be turned off by negative charge accumulating in interface states and compensating radiation-induced positive charge building up inside thick isolation oxides. Effects associated with ionization and hydrogen transport in spacer oxides may become dominant at 600 Mrad(SiO2) and may explain the observed noise behavior at extremely high TID. The results of this analysis provide an understanding o...

  6. Acceptable noise level

    DEFF Research Database (Denmark)

    Olsen, Steen Østergaard; Nielsen, Lars Holme; Lantz, Johannes

    2012-01-01

    The acceptable noise level (ANL) is used to quantify the amount of background noise that subjects can accept while listening to speech, and is suggested for prediction of individual hearing-aid use. The aim of this study was to assess the repeatability of the ANL measured in normal-hearing subjects...... using running Danish and non-semantic speech materials as stimuli and modulated speech-spectrum and multi-talker babble noises as competing stimuli....

  7. Acceptable noise level

    DEFF Research Database (Denmark)

    Olsen, Steen Østergaard; Nielsen, Lars Holme; Lantz, Johannes

    2012-01-01

    The acceptable noise level (ANL) is used to quantify the amount of background noise that subjects can accept while listening to speech, and is suggested for prediction of individual hearing-aid use. The aim of this study was to assess the repeatability of the ANL measured in normal-hearing subjec...... using running Danish and non-semantic speech materials as stimuli and modulated speech-spectrum and multi-talker babble noises as competing stimuli....

  8. Background noise levels in Europe

    OpenAIRE

    Gjestland, Truls

    2008-01-01

    - This report gives a brief overview of typical background noise levels in Europe, and suggests a procedure for the prediction of background noise levels based on population density. A proposal for the production of background noise maps for Europe is included.

  9. Noise levels in Damascus city

    International Nuclear Information System (INIS)

    Al-Oudat, M.; Maslmani, Y.

    2004-01-01

    Outdoor noise levels were measured at 22 sites in Damascus city. Sound level meter model NC-10 with a 20-140 dBA selectable range was used in the current investigation. At each site noise data were collected from 7 to 21 o'clock. The results showed that the noise levels were higher than WHO (World Health Organization) standard by 5-24.7 dB, 10-16 dB, 10-11 dB and 12-17 dB in residential, commercial, Commercial-industrial, and Heavy traffic streets respectively. Indoor and outdoor noise levels in some hospitals were higher than WHO standard by 15-28 dB and 19-23 dB respectively. The study showed that the authorities administration must take necessary procedures to reduce the noise levels in residential regions and in the regions surrounding the hospitals. (author)

  10. High level white noise generator

    International Nuclear Information System (INIS)

    Borkowski, C.J.; Blalock, T.V.

    1979-01-01

    A wide band, stable, random noise source with a high and well-defined output power spectral density is provided which may be used for accurate calibration of Johnson Noise Power Thermometers (JNPT) and other applications requiring a stable, wide band, well-defined noise power spectral density. The noise source is based on the fact that the open-circuit thermal noise voltage of a feedback resistor, connecting the output to the input of a special inverting amplifier, is available at the amplifier output from an equivalent low output impedance caused by the feedback mechanism. The noise power spectral density level at the noise source output is equivalent to the density of the open-circuit thermal noise or a 100 ohm resistor at a temperature of approximately 64,000 Kelvins. The noise source has an output power spectral density that is flat to within 0.1% (0.0043 db) in the frequency range of from 1 KHz to 100 KHz which brackets typical passbands of the signal-processing channels of JNPT's. Two embodiments, one of higher accuracy that is suitable for use as a standards instrument and another that is particularly adapted for ambient temperature operation, are illustrated in this application

  11. High level white noise generator

    Science.gov (United States)

    Borkowski, Casimer J.; Blalock, Theron V.

    1979-01-01

    A wide band, stable, random noise source with a high and well-defined output power spectral density is provided which may be used for accurate calibration of Johnson Noise Power Thermometers (JNPT) and other applications requiring a stable, wide band, well-defined noise power spectral density. The noise source is based on the fact that the open-circuit thermal noise voltage of a feedback resistor, connecting the output to the input of a special inverting amplifier, is available at the amplifier output from an equivalent low output impedance caused by the feedback mechanism. The noise power spectral density level at the noise source output is equivalent to the density of the open-circuit thermal noise or a 100 ohm resistor at a temperature of approximately 64,000 Kelvins. The noise source has an output power spectral density that is flat to within 0.1% (0.0043 db) in the frequency range of from 1 KHz to 100 KHz which brackets typical passbands of the signal-processing channels of JNPT's. Two embodiments, one of higher accuracy that is suitable for use as a standards instrument and another that is particularly adapted for ambient temperature operation, are illustrated in this application.

  12. Seismic random noise attenuation using shearlet and total generalized variation

    International Nuclear Information System (INIS)

    Kong, Dehui; Peng, Zhenming

    2015-01-01

    Seismic denoising from a corrupted observation is an important part of seismic data processing which improves the signal-to-noise ratio (SNR) and resolution. In this paper, we present an effective denoising method to attenuate seismic random noise. The method takes advantage of shearlet and total generalized variation (TGV) regularization. Different regularity levels of TGV improve the quality of the final result by suppressing Gibbs artifacts caused by the shearlet. The problem is formulated as mixed constraints in a convex optimization. A Bregman algorithm is proposed to solve the proposed model. Extensive experiments based on one synthetic datum and two post-stack field data are done to compare performance. The results demonstrate that the proposed method provides superior effectiveness and preserve the structure better. (paper)

  13. Seismic random noise attenuation using shearlet and total generalized variation

    Science.gov (United States)

    Kong, Dehui; Peng, Zhenming

    2015-12-01

    Seismic denoising from a corrupted observation is an important part of seismic data processing which improves the signal-to-noise ratio (SNR) and resolution. In this paper, we present an effective denoising method to attenuate seismic random noise. The method takes advantage of shearlet and total generalized variation (TGV) regularization. Different regularity levels of TGV improve the quality of the final result by suppressing Gibbs artifacts caused by the shearlet. The problem is formulated as mixed constraints in a convex optimization. A Bregman algorithm is proposed to solve the proposed model. Extensive experiments based on one synthetic datum and two post-stack field data are done to compare performance. The results demonstrate that the proposed method provides superior effectiveness and preserve the structure better.

  14. Influence of urban morphology on total noise pollution: multifractal description.

    Science.gov (United States)

    Ariza-Villaverde, Ana B; Jiménez-Hornero, Francisco J; Gutiérrez De Ravé, Eduardo

    2014-02-15

    Exposure to ambient noise levels above 65 dB can cause public health problems. The spatial distribution of this kind of pollution is linked to various elements which make up the urban form, such as construction density, the existence of open spaces and the shape and physical position of buildings. Since urban morphology displays multifractal behaviour, the present research studies for the first time the relationship between total noise pollution and urban features, such as street width and building height by means of a joint multifractal spectrum in two neighbourhoods of the city of Cordoba (Andalusia, Spain). According to the results, the joint multifractal spectrum reveals a positive correlation between the total noise pollution and the street width to building height ratio, this being more evident when urban morphology is regular. The information provided by the multifractal analysis completes the description obtained by using urban indexes and landscape metrics and might be useful for urban planning once the linkage between both frameworks has been done. Copyright © 2013 Elsevier B.V. All rights reserved.

  15. Noise in restaurants: levels and mathematical model.

    Science.gov (United States)

    To, Wai Ming; Chung, Andy

    2014-01-01

    Noise affects the dining atmosphere and is an occupational hazard to restaurant service employees worldwide. This paper examines the levels of noise in dining areas during peak hours in different types of restaurants in Hong Kong SAR, China. A mathematical model that describes the noise level in a restaurant is presented. The 1-h equivalent continuous noise level (L(eq,1-h)) was measured using a Type-1 precision integral sound level meter while the occupancy density, the floor area of the dining area, and the ceiling height of each of the surveyed restaurants were recorded. It was found that the measured noise levels using Leq,1-h ranged from 67.6 to 79.3 dBA in Chinese restaurants, from 69.1 to 79.1 dBA in fast food restaurants, and from 66.7 to 82.6 dBA in Western restaurants. Results of the analysis of variance show that there were no significant differences between means of the measured noise levels among different types of restaurants. A stepwise multiple regression analysis was employed to determine the relationships between geometrical and operational parameters and the measured noise levels. Results of the regression analysis show that the measured noise levels depended on the levels of occupancy density only. By reconciling the measured noise levels and the mathematical model, it was found that people in restaurants increased their voice levels when the occupancy density increased. Nevertheless, the maximum measured hourly noise level indicated that the noise exposure experienced by restaurant service employees was below the regulated daily noise exposure value level of 85 dBA.

  16. Noise in restaurants: Levels and mathematical model

    Directory of Open Access Journals (Sweden)

    Wai Ming To

    2014-01-01

    Full Text Available Noise affects the dining atmosphere and is an occupational hazard to restaurant service employees worldwide. This paper examines the levels of noise in dining areas during peak hours in different types of restaurants in Hong Kong SAR, China. A mathematical model that describes the noise level in a restaurant is presented. The 1-h equivalent continuous noise level (Leq,1-h was measured using a Type-1 precision integral sound level meter while the occupancy density, the floor area of the dining area, and the ceiling height of each of the surveyed restaurants were recorded. It was found that the measured noise levels using Leq,1-h ranged from 67.6 to 79.3 dBA in Chinese restaurants, from 69.1 to 79.1 dBA in fast food restaurants, and from 66.7 to 82.6 dBA in Western restaurants. Results of the analysis of variance show that there were no significant differences between means of the measured noise levels among different types of restaurants. A stepwise multiple regression analysis was employed to determine the relationships between geometrical and operational parameters and the measured noise levels. Results of the regression analysis show that the measured noise levels depended on the levels of occupancy density only. By reconciling the measured noise levels and the mathematical model, it was found that people in restaurants increased their voice levels when the occupancy density increased. Nevertheless, the maximum measured hourly noise level indicated that the noise exposure experienced by restaurant service employees was below the regulated daily noise exposure value level of 85 dBA.

  17. Mixed Gaussian-Impulse Noise Image Restoration Via Total Variation

    Science.gov (United States)

    2012-05-01

    deblurring under impulse noise ,” J. Math. Imaging Vis., vol. 36, pp. 46–53, January 2010. [5] B. Li, Q. Liu, J. Xu, and X. Luo, “A new method for removing......Several Total Variation (TV) regularization methods have recently been proposed to address denoising under mixed Gaussian and impulse noise . While

  18. Practical ranges of loudness levels of various types of environmental noise, including traffic noise, aircraft noise, and industrial noise

    NARCIS (Netherlands)

    Salomons, E.M.; Janssen, S.A.

    2011-01-01

    In environmental noise control one commonly employs the A-weighted sound level as an approximate measure of the effect of noise on people. A measure that is more closely related to direct human perception of noise is the loudness level. At constant A-weighted sound level, the loudness level of a

  19. Practical Ranges of Loudness Levels of Various Types of Environmental Noise, Including Traffic Noise, Aircraft Noise, and Industrial Noise

    Directory of Open Access Journals (Sweden)

    Sabine A. Janssen

    2011-05-01

    Full Text Available In environmental noise control one commonly employs the A-weighted sound level as an approximate measure of the effect of noise on people. A measure that is more closely related to direct human perception of noise is the loudness level. At constant A-weighted sound level, the loudness level of a noise signal varies considerably with the shape of the frequency spectrum of the noise signal. In particular the bandwidth of the spectrum has a large effect on the loudness level, due to the effect of critical bands in the human hearing system. The low-frequency content of the spectrum also has an effect on the loudness level. In this note the relation between loudness level and A-weighted sound level is analyzed for various environmental noise spectra, including spectra of traffic noise, aircraft noise, and industrial noise. From loudness levels calculated for these environmental noise spectra, diagrams are constructed that show the relation between loudness level, A‑weighted sound level, and shape of the spectrum. The diagrams show that the upper limits of the loudness level for broadband environmental noise spectra are about 20 to 40 phon higher than the lower limits for narrowband spectra, which correspond to the loudness levels of pure tones. The diagrams are useful for assessing limitations and potential improvements of environmental noise control methods and policy based on A-weighted sound levels.

  20. Nuisance levels of noise effects radiologists' performance

    Science.gov (United States)

    McEntee, Mark F.; Coffey, Amina; Ryan, John; O'Beirne, Aaron; Toomey, Rachel; Evanoff, Micheal; Manning, David; Brennan, Patrick C.

    2010-02-01

    This study aimed to measure the sound levels in Irish x-ray departments. The study then established whether these levels of noise have an impact on radiologists performance Noise levels were recorded 10 times within each of 14 environments in 4 hospitals, 11 of which were locations where radiologic images are judged. Thirty chest images were then presented to 26 senior radiologists, who were asked to detect up to three nodular lesions within 30 posteroanterior chest x-ray images in the absence and presence of noise at amplitude demonstrated in the clinical environment. The results demonstrated that noise amplitudes rarely exceeded that encountered with normal conversation with the maximum mean value for an image-viewing environment being 56.1 dB. This level of noise had no impact on the ability of radiologists to identify chest lesions with figure of merits of 0.68, 0.69, and 0.68 with noise and 0.65, 0.68, and 0.67 without noise for chest radiologists, non-chest radiologists, and all radiologists, respectively. the difference in their performance using the DBM MRMC method was significantly better with noise than in the absence of noise at the 90% confidence interval (p=0.077). Further studies are required to establish whether other aspects of diagnosis are impaired such as recall and attention and the effects of more unexpected noise on performance.

  1. Partial and Total Annoyance Due to Road Traffic Noise Combined with Aircraft or Railway Noise: Structural Equation Analysis

    OpenAIRE

    Gille, Laure-Anne; Marquis-Favre, Catherine; Lam, Kin-Che

    2017-01-01

    Structural equation modeling was used to analyze partial and total in situ annoyance in combined transportation noise situations. A psychophysical total annoyance model and a perceptual total annoyance model were proposed. Results show a high contribution of Noise exposure and Noise sensitivity to Noise annoyance, as well as a causal relationship between noise annoyance and lower Dwelling satisfaction. Moreover, the Visibility of noise source may increase noise annoyance, even when the visibl...

  2. Definition of 1992 Technology Aircraft Noise Levels and the Methodology for Assessing Airplane Noise Impact of Component Noise Reduction Concepts

    Science.gov (United States)

    Kumasaka, Henry A.; Martinez, Michael M.; Weir, Donald S.

    1996-01-01

    This report describes the methodology for assessing the impact of component noise reduction on total airplane system noise. The methodology is intended to be applied to the results of individual study elements of the NASA-Advanced Subsonic Technology (AST) Noise Reduction Program, which will address the development of noise reduction concepts for specific components. Program progress will be assessed in terms of noise reduction achieved, relative to baseline levels representative of 1992 technology airplane/engine design and performance. In this report, the 1992 technology reference levels are defined for assessment models based on four airplane sizes - an average business jet and three commercial transports: a small twin, a medium sized twin, and a large quad. Study results indicate that component changes defined as program final goals for nacelle treatment and engine/airframe source noise reduction would achieve from 6-7 EPNdB reduction of total airplane noise at FAR 36 Stage 3 noise certification conditions for all of the airplane noise assessment models.

  3. Period analysis at high noise level

    International Nuclear Information System (INIS)

    Kovacs, G.

    1980-01-01

    Analytical expressions are derived for the variances of some types of the periodograms due to normal-distributed noise present in the data. The equivalence of the Jurkevich and the Warner and Robinson methods is proved. The optimum phase cell number of the Warner and Robinson method is given; this number depends on the data length, signal form and noise level. The results are illustrated by numerical examples. (orig.)

  4. Salt-and-pepper noise removal using modified mean filter and total variation minimization

    Science.gov (United States)

    Aghajarian, Mickael; McInroy, John E.; Wright, Cameron H. G.

    2018-01-01

    The search for effective noise removal algorithms is still a real challenge in the field of image processing. An efficient image denoising method is proposed for images that are corrupted by salt-and-pepper noise. Salt-and-pepper noise takes either the minimum or maximum intensity, so the proposed method restores the image by processing the pixels whose values are either 0 or 255 (assuming an 8-bit/pixel image). For low levels of noise corruption (less than or equal to 50% noise density), the method employs the modified mean filter (MMF), while for heavy noise corruption, noisy pixels values are replaced by the weighted average of the MMF and the total variation of corrupted pixels, which is minimized using convex optimization. Two fuzzy systems are used to determine the weights for taking average. To evaluate the performance of the algorithm, several test images with different noise levels are restored, and the results are quantitatively measured by peak signal-to-noise ratio and mean absolute error. The results show that the proposed scheme gives considerable noise suppression up to a noise density of 90%, while almost completely maintaining edges and fine details of the original image.

  5. Ambient noise levels in the Taiwan region

    Science.gov (United States)

    Liang, W.; Liu, C.; Chen, R.; Huang, B.; Wu, F. T.; Wang, C.

    2008-12-01

    To characterize the island-wide background seismic noise in Taiwan, we estimate the power spectral density (PSD) at broadband stations of both the BATS (Broadband Array in Taiwan for Seismology) and the TAIGER experiment (Apr. 2006~Apr. 2008) for periods ranging from ~0.2 to 100 seconds. A new approach to calculate the probability density functions of noise power (PDFs, MaNamara and Buland, 2004) is used in this study. The results indicate that the cultural noise at higher frequencies is significant at populated area, which shows diurnal and weekly variation as what we expected. The noise power for microseisms centered at a period of ~5 seconds around the western costal plain show ~20dB higher than what observed at eastern Taiwan. This observation supports the inference that the coastal regions having narrow shelf with irregular coastlines are know to be especially efficient at radiating the predominat microseisms. Results from the linear array across central Taiwan demonstrate that the average noise power is quietest at the eastern Central Range. We have mapped the PDF mode for stations at various periods to see the spatial distribution of ambient noise levels, which could be used as the basic information for future station siting. Temporal variation of noise PSD is also present to provide a quantitative description of the seismic data quality collected by both BATS and TAIGER experiment. Some operational problems like base tilt, sensitivity change can be identified easily as well.

  6. Effect of external classroom noise on schoolchildren's reading and mathematics performance: correlation of noise levels and gender.

    Science.gov (United States)

    Papanikolaou, M; Skenteris, N; Piperakis, S M

    2015-02-01

    The present study investigated the effect of low, medium, and high traffic road noise as well as irrelevant background speech noise on primary school children's reading and mathematical performance. A total of 676 participants (324 boys, 47.9% and 352 girls, 52.1%) of the 4th and 5th elementary classes participated in the project. The participants were enrolled in public primary schools from urban areas and had ages ranging from 9 to 10 years and from. Schools were selected on the basis of increasing levels of exposure to road traffic noise and then classified into three categories (Low noise: 55-66 dB, Medium noise: 67-77 dB, and High noise: 72-80 dB). We measured reading comprehension and mathematical skills in accordance with the national guidelines for elementary education, using a test designed specifically for the purpose of this study. On the one hand, children in low-level noise schools showed statistically significant differences from children in medium- and high-level noise schools in reading performance (plevel noise schools differed significantly from children in high-level noise schools but only in mathematics performance (p=0.001). Girls in general did better in reading score than boys, especially in schools with medium- and high-level noise. Finally the levels of noise and gender were found to be two independent factors.

  7. Seismic noise level variation in South Korea

    Science.gov (United States)

    Sheen, D.; Shin, J.

    2008-12-01

    The variations of seismic background noise in South Korea have been investigated by means of power spectral analysis. The Korea Institute of Geoscience and Mineral Resources (KIGAM) and the Korea Meteorological Administation (KMA) have national wide seismic networks in South Korea, and, in the end of 2007, there are 30 broadband stations which have been operating for more than a year. In this study, we have estimated the power spectral density of seismic noise for 30 broadband stations from 2005 to 2007. Since we estimate PSDs from a large dataset of continuous waveform in this study, a robust PSD estimate of McNamara and Buland (2004) is used. In the frequency range 1-5 Hz, the diurnal variations of noise are observed at most of stations, which are especially larger at coastal stations and at insular than at inland. Some stations shows daily difference of diurnal variations, which represents that cultural activities contribute to the noise level of a station. The variation of number of triggered stations, however, shows that cultural noise has little influence on the detection capability of seismic network in South Korea. Seasonal variations are observed well in the range 0.1-0.5 Hz, while much less found in the frequency range 1-5 Hz. We observed that strong peaks in the range 0.1-0.5 Hz occur at the summer when Pacific typhoons are close to the Korean Peninsula.

  8. Total annoyance from an industrial noise source with a main spectral component combined with a background noise.

    Science.gov (United States)

    Alayrac, M; Marquis-Favre, C; Viollon, S

    2011-07-01

    When living close to an industrial plant, people are exposed to a combination of industrial noise sources and a background noise composed of all the other noise sources in the environment. As a first step, noise annoyance indicators in laboratory conditions are proposed for a single exposure to an industrial noise source. The second step detailed in this paper involves determining total annoyance indicators in laboratory conditions for ambient noises composed of an industrial noise source and a background noise. Two types of steady and permanent industrial noise sources are studied: low frequency noises with a main spectral component at 100 Hz, and noises with a main spectral component in middle frequencies. Five background noises are assessed so as to take into account different sound environments which can usually be heard by people living around an industrial plant. One main conclusion of this study is that two different analyses are necessary to determine total annoyance indicators for this type of ambient noise, depending on the industrial noise source composing it. Therefore, two total annoyance indicators adapted to the ambient noises studied are proposed. © 2011 Acoustical Society of America

  9. The Effect of Age and Type of Noise on Speech Perception under Conditions of Changing Context and Noise Levels.

    Science.gov (United States)

    Taitelbaum-Swead, Riki; Fostick, Leah

    2016-01-01

    Everyday life includes fluctuating noise levels, resulting in continuously changing speech intelligibility. The study aims were: (1) to quantify the amount of decrease in age-related speech perception, as a result of increasing noise level, and (2) to test the effect of age on context usage at the word level (smaller amount of contextual cues). A total of 24 young adults (age 20-30 years) and 20 older adults (age 60-75 years) were tested. Meaningful and nonsense one-syllable consonant-vowel-consonant words were presented with the background noise types of speech noise (SpN), babble noise (BN), and white noise (WN), with a signal-to-noise ratio (SNR) of 0 and -5 dB. Older adults had lower accuracy in SNR = 0, with WN being the most difficult condition for all participants. Measuring the change in speech perception when SNR decreased showed a reduction of 18.6-61.5% in intelligibility, with age effect only for BN. Both young and older adults used less phonemic context with WN, as compared to other conditions. Older adults are more affected by an increasing noise level of fluctuating informational noise as compared to steady-state noise. They also use less contextual cues when perceiving monosyllabic words. Further studies should take into consideration that when presenting the stimulus differently (change in noise level, less contextual cues), other perceptual and cognitive processes are involved. © 2016 S. Karger AG, Basel.

  10. PENGHILANGAN NOISE PADA CITRA BERWARNA DENGAN METODE TOTAL VARIATION

    Directory of Open Access Journals (Sweden)

    Anny Yuniarti

    2006-01-01

    Full Text Available Normal 0 false false false IN X-NONE X-NONE MicrosoftInternetExplorer4 /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-priority:99; mso-style-qformat:yes; mso-style-parent:""; mso-padding-alt:0cm 5.4pt 0cm 5.4pt; mso-para-margin:0cm; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:11.0pt; font-family:"Calibri","sans-serif"; mso-ascii-font-family:Calibri; mso-ascii-theme-font:minor-latin; mso-fareast-font-family:"Times New Roman"; mso-fareast-theme-font:minor-fareast; mso-hansi-font-family:Calibri; mso-hansi-theme-font:minor-latin; mso-bidi-font-family:"Times New Roman"; mso-bidi-theme-font:minor-bidi;} Saat ini multimedia telah menjadi teknologi yang cukup dominan. Tukar menukar informasi dalam bentuk citra sudah banyak dilakukan oleh masyarakat. Citra dengan kualitas yang baik sangat diperlukan dalam penyajian informasi. Citra yang memiliki noise kurang baik digunakan sebagai sarana informasi, oleh karena itu diperlukan suatu metode untuk memperbaiki kualitas citra. Metode yang digunakan dalam penelitian ini adalah metode total variation untuk penghilangan noise yang dapat diterapkan untuk model warna nonlinier, yaitu Chromaticity-Brightness (CB dan Hue-Saturation-Value (HSV. Filter total variation disebut filter yang bergantung pada data citra karena koefisien filternya diperoleh dari pemrosesan data citra dengan rumusan yang baku. Sehingga filter mask untuk masing-masing piksel memiliki kombinasi koefisien yang berbeda. Metode ini menggunakan proses iterasi untuk menyelesaikan persamaan dasar yang nonlinier. Uji coba dilakukan dengan menggunakan 30 data dengan berbagai jenis noise, yaitu gaussian, salt and pepper dan speckle. Uji coba pembandingan dengan metode filter median dan filter rata-rata. Dari percobaan ini menunjukkan bahwa metode total variation menghasilkan citra yang lebih baik daripada metode

  11. Speckle Noise Reduction via Nonconvex High Total Variation Approach

    Directory of Open Access Journals (Sweden)

    Yulian Wu

    2015-01-01

    Full Text Available We address the problem of speckle noise removal. The classical total variation is extensively used in this field to solve such problem, but this method suffers from the staircase-like artifacts and the loss of image details. In order to resolve these problems, a nonconvex total generalized variation (TGV regularization is used to preserve both edges and details of the images. The TGV regularization which is able to remove the staircase effect has strong theoretical guarantee by means of its high order smooth feature. Our method combines the merits of both the TGV method and the nonconvex variational method and avoids their main drawbacks. Furthermore, we develop an efficient algorithm for solving the nonconvex TGV-based optimization problem. We experimentally demonstrate the excellent performance of the technique, both visually and quantitatively.

  12. Noise pollution levels in the pediatric intensive care unit.

    Science.gov (United States)

    Kramer, Bree; Joshi, Prashant; Heard, Christopher

    2016-12-01

    Patients and staff may experience adverse effects from exposure to noise. This study assessed noise levels in the pediatric intensive care unit and evaluated family and staff opinion of noise. Noise levels were recorded using a NoisePro DLX. The microphone was 1 m from the patient's head. The noise level was averaged each minute and levels above 70 and 80 dBA were recorded. The maximum, minimum, and average decibel levels were calculated and peak noise level great than 100 dBA was also recorded. A parent questionnaire concerning their evaluation of noisiness of the bedside was completed. The bedside nurse also completed a questionnaire. The average maximum dB for all patients was 82.2. The average minimum dB was 50.9. The average daily bedside noise level was 62.9 dBA. The average % time where the noise level was higher than 70 dBA was 2.2%. The average percent of time that the noise level was higher than 80 dBA was 0.1%. Patients experienced an average of 115 min/d where peak noise was greater than 100 dBA. The parents and staff identified the monitors as the major contribution to noise. Patients experienced levels of noise greater than 80 dBA. Patients experience peak noise levels in excess of 100 dB during their pediatric intensive care unit stay. Copyright © 2016 Elsevier Inc. All rights reserved.

  13. Are the noise levels acceptable in a built environment like Hong Kong?

    Science.gov (United States)

    To, Wai Ming; Mak, Cheuk Ming; Chung, Wai Leung

    2015-01-01

    Governments all over the world have enacted environmental noise directives and noise control ordinances/acts to protect tranquility in residential areas. However, there is a lack of literature on the evaluation of whether the Acceptable Noise Levels (ANLs) stipulated in the directive/ordinance/act are actually achievable. The study aimed at measuring outdoor environmental noise levels in Hong Kong and identifying whether the measured noise levels are lower than the stipulated ANLs at 20 categories of residential areas. Data were gathered from a territory-wide noise survey. Outdoor noise measurements were conducted at 203 residential premises in urban areas, low-density residential areas, rural areas, and other areas. In total, 366 daytime hourly Leq outdoor noise levels, 362 nighttime hourly Leq outdoor noise levels, and 20 sets of daily, that is, 24 Leq,1-h outdoor noise levels were recorded. The mean daytime Leq,1-h values ranged 54.4-70.8 dBA, while the mean nighttime Leq,1-h values ranged 52.6-67.9 dBA. When the measured noise levels were compared with the stipulated ANLs, only three out of the 20 categories of areas had outdoor noise levels below ANLs during daytime. All other areas (and all areas during nighttime) were found to have outdoor noise levels at or above ANLs. PMID:26572703

  14. Noise level in a pediatric intensive care unit.

    Science.gov (United States)

    Carvalho, Werther B; Pedreira, Mavilde L G; de Aguiar, Maria Augusta L

    2005-01-01

    The purpose of this study was to verify the noise level at a PICU. This prospective observational study was performed in a 10 bed PICU at a teaching hospital located in a densely populated district within the city of São Paulo, Brazil. Sound pressure levels (dBA) were measured 24 hours during a 6-day period. Noise recording equipment was placed in the PICU access corridor, nursing station, two open wards with three and five beds, and in isolation rooms. The resulting curves were analyzed. A basal noise level variation between 60 and 70 dBA was identified, with a maximum level of 120 dBA. The most significant noise levels were recorded during the day and were produced by the staff. The basal noise level identified exceeds International Noise Council recommendations. Education regarding the effects of noise on human hearing and its relation to stress is the essential basis for the development of a noise reduction program.

  15. Existing Noise Level at Railway Stations in Malaysia

    Directory of Open Access Journals (Sweden)

    Shahidan Shahiron

    2017-01-01

    Full Text Available Railway transportation known as one of the most environmental friendly transportation mode. However, the significance problems of railway transportation are noise pollution and negatively impact the wellbeing of the whole community. Unfortunately, there has been lack of public awareness about the noise level produce by the railway transportation in Malaysia. This study investigates the noise level produced by railway transportation in Malaysia specifically by Keretapi Tanah Melayu Berhad (KTMB. Methods of collecting existing noise level at railway stations in Malaysia are briefly discussed in this study. The finding indicates that the noise level produced by the railway transportation in Malaysia which is by KTMB is considered as dangerous to human being and also exceed the noise limit that has been assigned by Department of Environment Ministry of Natural Resources and Environment of Malaysia. A better noise barrier and improved material should be developed to mitigate the existing noise level produced by railway transportations in Malaysia.

  16. Directional Total Generalized Variation Regularization for Impulse Noise Removal

    DEFF Research Database (Denmark)

    Kongskov, Rasmus Dalgas; Dong, Yiqiu

    2017-01-01

    this regularizer for directional images is highly advantageous. In order to estimate directions in impulse noise corrupted images, which is much more challenging compared to Gaussian noise corrupted images, we introduce a new Fourier transform-based method. Numerical experiments show that this method is more...

  17. [Noise level in a care and teaching hospital institution].

    Science.gov (United States)

    Mendoza-Sánchez, R S; Roque-Sánchez, R H; Moncada-González, B

    1996-01-01

    Noise in the environment is increasing over the years. Disturbances produced by noise are varied, some lead to serious health consequences. Noise level was registered in a teaching hospital. Levels in the wards were between 50 and 59 dB. In the Intensive Care Unit, main hallways and outpatients department levels were higher than 59 dB. Isolated peaks up to 90.0 dB (Pediatrics) were detected. The noise level recommended for a hospital is under 50.0 dB. We found that the principal source of noise came from the medical and nursing staff.

  18. Noise level and MPEG-2 encoder statistics

    Science.gov (United States)

    Lee, Jungwoo

    1997-01-01

    Most software in the movie and broadcasting industries are still in analog film or tape format, which typically contains random noise that originated from film, CCD camera, and tape recording. The performance of the MPEG-2 encoder may be significantly degraded by the noise. It is also affected by the scene type that includes spatial and temporal activity. The statistical property of noise originating from camera and tape player is analyzed and the models for the two types of noise are developed. The relationship between the noise, the scene type, and encoder statistics of a number of MPEG-2 parameters such as motion vector magnitude, prediction error, and quant scale are discussed. This analysis is intended to be a tool for designing robust MPEG encoding algorithms such as preprocessing and rate control.

  19. Adaptive EMG noise reduction in ECG signals using noise level approximation

    Science.gov (United States)

    Marouf, Mohamed; Saranovac, Lazar

    2017-12-01

    In this paper the usage of noise level approximation for adaptive Electromyogram (EMG) noise reduction in the Electrocardiogram (ECG) signals is introduced. To achieve the adequate adaptiveness, a translation-invariant noise level approximation is employed. The approximation is done in the form of a guiding signal extracted as an estimation of the signal quality vs. EMG noise. The noise reduction framework is based on a bank of low pass filters. So, the adaptive noise reduction is achieved by selecting the appropriate filter with respect to the guiding signal aiming to obtain the best trade-off between the signal distortion caused by filtering and the signal readability. For the evaluation purposes; both real EMG and artificial noises are used. The tested ECG signals are from the MIT-BIH Arrhythmia Database Directory, while both real and artificial records of EMG noise are added and used in the evaluation process. Firstly, comparison with state of the art methods is conducted to verify the performance of the proposed approach in terms of noise cancellation while preserving the QRS complex waves. Additionally, the signal to noise ratio improvement after the adaptive noise reduction is computed and presented for the proposed method. Finally, the impact of adaptive noise reduction method on QRS complexes detection was studied. The tested signals are delineated using a state of the art method, and the QRS detection improvement for different SNR is presented.

  20. Noise levels, noise annoyance, and hearing-related problems in a dental college.

    Science.gov (United States)

    Ahmed, Hafiz Omer; Ali, Wesal Jasim

    2017-05-04

    Through a cross-sectional survey and integrated sound level meter, this research examined noise exposure and auditory- and nonauditory-related problems experienced by students of a dentistry college located in the United Arab Emirates (UAE). A structured interview questionnaire was used to examine hearing-related problems, noise annoyance, and awareness of 114 students toward noise. The results showed that maximum noise levels were between 65 and 79 dB(A) with peak levels (high and low frequencies) ranging between 89 and 93 dB(A). Around 80% of the students experienced a certain degree of noise annoyance; 54% reported one of the hearing-related problems; and about 10% claimed to have hearing loss to a certain extent. It is recommended that sound-absorbent materials be used during the construction of dental clinics and laboratories to reduce the noise levels.

  1. Evaluation of noise pollution level based upon community exposure and response data

    Science.gov (United States)

    Edmiston, R. D.

    1972-01-01

    The results and procedures are reported from an evaluation of noise pollution level as a predictor of annoyance, based on aircraft noise exposure and community response data. The measures of noise exposure presented include composite noise rating, noise exposure forecast, noise and number index. A proposed measure as a universal noise exposure measure for noise pollution level (L sub NP) is discussed.

  2. Equivalent noise level response to number of vehicles: a comparison between a high traffic flow and low traffic flow highway in Klang Valley, Malaysia

    OpenAIRE

    Halim, Herni; Abdullah, Ramdzani

    2014-01-01

    HIGHLIGHTS Highway traffic noise is a serious problem in Malaysia Heavy traffic flow highway recorded higher noise level compared to low traffic flow Noise level stabilized at certain number of vehicles on the road i.e above 500 vehicles. Although much research on road traffic noise has found that noise level increase are influenced by driver behavior and source-receiver distance, little attention has been paid to the relationship between noise level and total number of vehicles...

  3. Investigations of internal noise levels for different target sizes, contrasts, and noise structures

    Science.gov (United States)

    Han, Minah; Choi, Shinkook; Baek, Jongduk

    2014-03-01

    To describe internal noise levels for different target sizes, contrasts, and noise structures, Gaussian targets with four different sizes (i.e., standard deviation of 2,4,6 and 8) and three different noise structures(i.e., white, low-pass, and highpass) were generated. The generated noise images were scaled to have standard deviation of 0.15. For each noise type, target contrasts were adjusted to have the same detectability based on NPW, and the detectability of CHO was calculated accordingly. For human observer study, 3 trained observers performed 2AFC detection tasks, and correction rate, Pc, was calculated for each task. By adding proper internal noise level to numerical observer (i.e., NPW and CHO), detectability of human observer was matched with that of numerical observers. Even though target contrasts were adjusted to have the same detectability of NPW observer, detectability of human observer decreases as the target size increases. The internal noise level varies for different target sizes, contrasts, and noise structures, demonstrating different internal noise levels should be considered in numerical observer to predict the detection performance of human observer.

  4. Noise Levels in Dental Offices and Laboratories in Hamedan, Iran

    Directory of Open Access Journals (Sweden)

    F. Mojarad

    2009-12-01

    Full Text Available Objective: Noise pollution is one of the most important situations requiring a solution by the contemporary world. The National Institute for Occupational Safety and Health has identified noise as one of the ten leading causes of work-related diseases and injuries.Dentists and dental auxiliaries are exposed to different noise levels while working in dental offices or laboratories. The purpose of this study was to measure the noise level made by different dental instruments in dental offices and laboratories.Materials and Methods: Measurement of the noise level was performed in 89 dental offices and nine dental laboratories. The noise levels were determined using a sound level meter; type SL-4011(Lutron ,which was placed at the operator’s ear level in dental offices and laboratories and also at two-meter distance from the technician’s ear in laboratories.Results: The maximum sound level was 85.8 dB in dental offices and 92.0 dB in laboratories.In dental clinics, the highest noise was produced by the ultrasonic-scaler (85.8 dB and the lowest noise (49.7 dB by the high-volume aspirator, whereas in the laboratory,the highest noise was caused during grinding by the stonecutter (92.0 dB and the lowest by the denture-polishing unit (41.0 dB.Conclusion: After close evaluation, we believe that the maximum noise level in dental offices, although often beneath the damaging noise level for the human ear, is very close to the limit of hearing loss (85.0 dB. However, laboratory technicians may be at risk ifthey choose not to wear ear protection (earplugs or earmuffs.

  5. Ambient and at-the-ear occupational noise exposure and serum lipid levels

    DEFF Research Database (Denmark)

    Arlien-Søborg, Mai C; Schmedes, Astrid S; Stokholm, Z A

    2016-01-01

    -the-ear occupational noise exposure and serum levels of total cholesterol, low-density lipoprotein-cholesterol, high-density lipoprotein-cholesterol, and triglycerides when accounting for well-established predictors of lipid levels. METHODS: This cross-sectional study included 424 industrial workers and 84 financial......OBJECTIVES: Occupational and residential noise exposure has been related to increased risk of cardiovascular disease. Alteration of serum lipid levels has been proposed as a possible causal pathway. The objective of this study was to investigate the relation between ambient and at...... workers to obtain contrast in noise exposure levels. They provided a serum sample and wore portable dosimeters that every 5-s recorded ambient noise exposure levels during a 24-h period. We extracted measurements obtained during work and calculated the full-shift mean ambient noise level. For 331 workers...

  6. Predictive modelling of noise level generated during sawing of rocks

    Indian Academy of Sciences (India)

    This paper presents an experimental and statistical study on noise level generated during of rock sawing by circular diamond sawblades. Influence of the operating variables and rock properties on the noise level are investigated and analysed. Statistical analyses are then employed and models are built for the prediction of ...

  7. Profiles of noise exposure levels in South African mining

    CSIR Research Space (South Africa)

    Edwards, A

    2011-05-01

    Full Text Available were exposed to noise levels of above the 85 dBA legislated occupational exposure level. The conclusion was made that information obtained through the study could be developed into a national personal noise exposure database, including audiometric...

  8. Pilot survey of subway and bus stop noise levels.

    Science.gov (United States)

    Gershon, Robyn R M; Neitzel, Richard; Barrera, Marissa A; Akram, Muhammad

    2006-09-01

    Excessive noise exposure is a serious global urban health problem, adversely affecting millions of people. One often cited source of urban noise is mass transit, particularly subway systems. As a first step in determining risk within this context, we recently conducted an environmental survey of noise levels of the New York City transit system. Over 90 noise measurements were made using a sound level meter. Average and maximum noise levels were measured on subway platforms, and maximum levels were measured inside subway cars and at several bus stops for comparison purposes. The average noise level measured on the subway platforms was 86 +/- 4 dBA (decibel-A weighting). Maximum levels of 106, 112, and 89 dBA were measured on subway platforms, inside subway cars, and at bus stops, respectively. These results indicate that noise levels in subway and bus stop environments have the potential to exceed recommended exposure guidelines from the World Health Organization (WHO) and U.S. Environmental Protection Agency (EPA), given sufficient exposure duration. Risk reduction strategies following the standard hierarchy of control measures should be applied, where feasible, to reduce subway noise exposure.

  9. REDUCTION OF CLASSROOM NOISE LEVELS USING GROUP CONTINGENCIES

    OpenAIRE

    Ring, Brandon M.; Sigurdsson, Sigurdur O.; Eubanks, Sean L.; Silverman, Kenneth

    2014-01-01

    The therapeutic workplace is an employment-based abstinence reinforcement intervention for unemployed drug users where trainees receive on-the-job employment skills training in a classroom setting. The study is an extension of prior therapeutic workplace research, which suggested that trainees frequently violated noise standards. Participants received real-time graphed feedback of noise levels and had the opportunity to earn monetary group reinforcement for maintaining a low number of noise v...

  10. Training Methods for Image Noise Level Estimation on Wavelet Components

    Directory of Open Access Journals (Sweden)

    A. De Stefano

    2004-12-01

    Full Text Available The estimation of the standard deviation of noise contaminating an image is a fundamental step in wavelet-based noise reduction techniques. The method widely used is based on the mean absolute deviation (MAD. This model-based method assumes specific characteristics of the noise-contaminated image component. Three novel and alternative methods for estimating the noise standard deviation are proposed in this work and compared with the MAD method. Two of these methods rely on a preliminary training stage in order to extract parameters which are then used in the application stage. The sets used for training and testing, 13 and 5 images, respectively, are fully disjoint. The third method assumes specific statistical distributions for image and noise components. Results showed the prevalence of the training-based methods for the images and the range of noise levels considered.

  11. evaluation of the environmental noise levels in abuja municipality

    African Journals Online (AJOL)

    ABSTRACT. Background: Noise remains a nuisance which impacts negatively on the ..... Furthermore, Erikson et al postulated that a persistent noise level .... Hessel PA, Sluis-Cremer G K. Hearing loss in ... Ear & Hearing 2006; 27(1): 1-19. 13.

  12. Can weekly noise levels of urban road traffic, as predominant noise source, estimate annual ones?

    Science.gov (United States)

    Prieto Gajardo, Carlos; Barrigón Morillas, Juan Miguel; Rey Gozalo, Guillermo; Vílchez-Gómez, Rosendo

    2016-11-01

    The effects of noise pollution on human quality of life and health were recognised by the World Health Organisation a long time ago. There is a crucial dilemma for the study of urban noise when one is looking for proven methodologies that can allow, on the one hand, an increase in the quality of predictions, and on the other hand, saving resources in the spatial and temporal sampling. The temporal structure of urban noise is studied in this work from a different point of view. This methodology, based on Fourier analysis, is applied to several measurements of urban noise, mainly from road traffic and one-week long, carried out in two cities located on different continents and with different sociological life styles (Cáceres, Spain and Talca, Chile). Its capacity to predict annual noise levels from weekly measurements is studied. The relation between this methodology and the categorisation method is also analysed.

  13. Predictive modelling of noise level generated during sawing of rocks ...

    Indian Academy of Sciences (India)

    This paper presents an experimental and statistical study on noise level generated .... hardness were determined according to related ISRM (1981) suggested methods. Thin section ..... tistical Package for the Social Sciences). Additionally, the ...

  14. Lateralization of noise bursts in interaurally correlated or uncorrelated background noise using interaural level differences.

    Science.gov (United States)

    Reed, Darrin K; van de Par, Steven

    2015-10-01

    The interaural level difference (ILD) of a lateralized target source may be effectively reduced when the target is presented together with background noise containing zero ILD. It is not certain whether listeners perceive a position congruent with the reduced ILD or the actual target ILD in a lateralization task. Two sets of behavioral experiments revealed that many listeners perceived a position at or even larger than that corresponding to the presented target ILD when a temporal onset/offset asynchrony between the broadband target and the broadband background noise was present. When no temporal asynchrony was present, however, the perceived lateral position indicated a dependency on the coherence of the background noise for several listeners. With interaurally correlated background noise, listeners reported a reduced ILD resulting from the combined target and background noise stimulus. In contrast, several of the listeners made a reasonable estimate of the position corresponding to the target ILD for interaurally uncorrelated, broadband, background noise. No obvious difference in performance was seen between low- or high-frequency stimuli. Extension of a weighting template to the output of a standard equalization-cancellation model was shown to remove a lateral bias on the predicted target ILD resulting from the presence of background noise. Provided that an appropriate weighting template is applied based on knowledge of the background noise coherence, good prediction of the behavioral data is possible.

  15. Reducing Indoor Noise Levels Using People's Perception on Greenery

    Science.gov (United States)

    Mediastika, Christina E.; Binarti, Floriberta

    2013-12-01

    Employees working in cubicles of open-plan offices in Indonesia were studied in regard to their perception on the ability of indoor greenery to reduce noise levels. Sansevieria trifasciata and Scindapsus sp were used. Each was placed in the cubicle and noise levels were measured without plants, with Sansevieria, and with Scindapsus in place. The meters showed very insignificant difference. However, responses to surveys indicated a perception of lower noise in the presence of greenery. This seemed to be supported by prior knowledge and preconception and may be useful in creating a "quieter" indoor environment.

  16. Studies on assessment of traffic noise level in Aurangabad city, India

    Directory of Open Access Journals (Sweden)

    B J Bhosale

    2010-01-01

    Full Text Available With the rapid rate of urbanization of Aurangabad city due to the expanding industrialization, the problem of noise pollution has become a concern for urban dwellers and government authority too. Noise pollution due to vehicular traffic is one of the growing environmental problems of urban centers. The study deals with the assessment of traffic noise levels in Aurangabad city. With respect to the total number of vehicles passing the road in unit time, which was surveyed by direct count method, six different sites from Aurangabad city, viz., Nagar Naka, Kranti Chowk, CIDCO bus stand, Railway station area, Dhoot Hospital and Baba petrol pump were selected to study the vehicular noise level. Noise measurements were carried out at these six locations on both working day and holiday during the peak traffic hours, i.e. 8:00 a.m. - 11:a.m., 1:00 p.m. - 4:00 p.m. and 5:00 p.m. - 8:00 p.m., in the morning, afternoon and evening sessions, respectively, after 5 minutes time interval. The noise level was monitored using noise level meter. The results obtained from this investigation showed that the Nagar Naka, Kranti chowk and CIDCO bus stand area have dense traffic zones when compared with the Railway station area, Dhoot Hospital and Baba petrol pump. The minimum and the maximum noise levels are 74 and 86 dB, respectively, on working day and 70 and 81 dB, respectively, on holiday. The measured noise level values exceed the prescribed noise level.

  17. Pilot task-based assessment of noise levels among firefighters.

    Science.gov (United States)

    Neitzel, Rl; Hong, O; Quinlan, P; Hulea, R

    2013-11-01

    Over one million American firefighters are routinely exposed to various occupational hazards agents. While efforts have been made to identify and reduce some causes of injuries and illnesses among firefighters, relatively little has been done to evaluate and understand occupational noise exposures in this group. The purpose of this pilot study was to apply a task-based noise exposure assessment methodology to firefighting operations to evaluate potential noise exposure sources, and to use collected task-based noise levels to create noise exposure estimates for evaluation of risk of noise-induced hearing loss by comparison to the 8-hr and 24-hr recommended exposure limits (RELs) for noise of 85 and 80.3 dBA, respectively. Task-based noise exposures (n=100 measurements) were measured in three different fire departments (a rural department in Southeast Michigan and suburban and urban departments in Northern California). These levels were then combined with time-at-task information collected from firefighters to estimate 8-hr noise exposures for the rural and suburban fire departments (n=6 estimates for each department). Data from 24-hr dosimetry measurements and crude self-reported activity categories from the urban fire department (n=4 measurements) were used to create 24-hr exposure estimates to evaluate the bias associated with the task-based estimates. Task-based noise levels were found to range from 82-109 dBA, with the highest levels resulting from use of saws and pneumatic chisels. Some short (e.g., 30 min) sequences of common tasks were found to result in nearly an entire allowable daily exposure. The majority of estimated 8-hr and 24-hr exposures exceeded the relevant recommended exposure limit. Predicted 24-hr exposures showed substantial imprecision in some cases, suggesting the need for increased task specificity. The results indicate potential for overexposure to noise from a variety of firefighting tasks and equipment, and suggest a need for further

  18. METHODS OF NOISE LEVEL REDUCTION OF DRIVE IN LATHES

    Directory of Open Access Journals (Sweden)

    Janusz ROGULA

    2014-06-01

    Full Text Available The aim of this work is method presentation to noise level reduction of fixed headstock of the lathe. It is connected with the causes finding of non-uniform work of lathe headstock, description of recent design and its analysis. Problem of the excessive noise level concern to near 35% of the lathes have been produced. In spite of lack of noise reduction possibility there were no system solution of problem. Design optimisation weren’t done after application the electric motor with inverter. New solution of electric motor control let to reduce number of gear wheels in lathe drive system. For this drive solution there weren’t made the analysis of drive particular parts influence on the noise generation.

  19. Preferred listening levels of mobile phone programs when considering subway interior noise.

    Science.gov (United States)

    Yu, Jyaehyoung; Lee, Donguk; Han, Woojae

    2016-01-01

    Today, people listen to music loud using personal listening devices. Although a majority of studies have reported that the high volume played on these listening devices produces a latent risk of hearing problems, there is a lack of studies on "double noise exposures" such as environmental noise plus recreational noise. The present study measures the preferred listening levels of a mobile phone program with subway interior noise for 74 normal-hearing participants in five age groups (ranging from 20s to 60s). The speakers presented the subway interior noise at 73.45 dB, while each subject listened to three application programs [Digital Multimedia Broadcasting (DMB), music, game] for 30 min using a tablet personal computer with an earphone. The participants' earphone volume levels were analyzed using a sound level meter and a 2cc coupler. Overall, the results showed that those in their 20s listened to the three programs significantly louder with DMB set at significantly higher volume levels than for the other programs. Higher volume levels were needed for middle frequency compared to the lower and higher frequencies. We concluded that any potential risk of noise-induced hearing loss for mobile phone users should be communicated when users listen regularly, although the volume level was not high enough that the users felt uncomfortable. When considering individual listening habits on mobile phones, further study to predict total accumulated environmental noise is still needed.

  20. Preferred listening levels of mobile phone programs when considering subway interior noise

    Directory of Open Access Journals (Sweden)

    Jyaehyoung Yu

    2016-01-01

    Full Text Available Today, people listen to music loud using personal listening devices. Although a majority of studies have reported that the high volume played on these listening devices produces a latent risk of hearing problems, there is a lack of studies on "double noise exposures" such as environmental noise plus recreational noise. The present study measures the preferred listening levels of a mobile phone program with subway interior noise for 74 normal-hearing participants in five age groups (ranging from 20s to 60s. The speakers presented the subway interior noise at 73.45 dB, while each subject listened to three application programs [Digital Multimedia Broadcasting (DMB, music, game] for 30 min using a tablet personal computer with an earphone. The participants′ earphone volume levels were analyzed using a sound level meter and a 2cc coupler. Overall, the results showed that those in their 20s listened to the three programs significantly louder with DMB set at significantly higher volume levels than for the other programs. Higher volume levels were needed for middle frequency compared to the lower and higher frequencies. We concluded that any potential risk of noise-induced hearing loss for mobile phone users should be communicated when users listen regularly, although the volume level was not high enough that the users felt uncomfortable. When considering individual listening habits on mobile phones, further study to predict total accumulated environmental noise is still needed.

  1. Decision-Based Marginal Total Variation Diffusion for Impulsive Noise Removal in Color Images

    Directory of Open Access Journals (Sweden)

    Hongyao Deng

    2017-01-01

    Full Text Available Impulsive noise removal for color images usually employs vector median filter, switching median filter, the total variation L1 method, and variants. These approaches, however, often introduce excessive smoothing and can result in extensive visual feature blurring and thus are suitable only for images with low density noise. A marginal method to reduce impulsive noise is proposed in this paper that overcomes this limitation that is based on the following facts: (i each channel in a color image is contaminated independently, and contaminative components are independent and identically distributed; (ii in a natural image the gradients of different components of a pixel are similar to one another. This method divides components into different categories based on different noise characteristics. If an image is corrupted by salt-and-pepper noise, the components are divided into the corrupted and the noise-free components; if the image is corrupted by random-valued impulses, the components are divided into the corrupted, noise-free, and the possibly corrupted components. Components falling into different categories are processed differently. If a component is corrupted, modified total variation diffusion is applied; if it is possibly corrupted, scaled total variation diffusion is applied; otherwise, the component is left unchanged. Simulation results demonstrate its effectiveness.

  2. LOW-NOISE PAVEMENT AS A WAY OF LIMITATION OF TRAFFIC NOISE LEVEL

    Directory of Open Access Journals (Sweden)

    Władysław Gardziejczyk

    2014-11-01

    Full Text Available Road surface can significantlyreduce the trafficnoise level. Depending on the characteristic of the upper surface layers the differences between the maximum rolling noise levels from passing vehicles to reach values about 10 dB (A. A special group is low-noise pavements characterized by the presence of voids above 15%. Application the porous asphalt layers or asphalt mixture type BBTM affects a significantreduction the width of land surrounded the roads where permissible equivalent sound level is exceeded. Such solutions in some cases can replace acoustic barriers. Road pavements with a higher content of voids require proper maintenance because their acoustic performances are reduced during operation.

  3. A comparative study of noise pollution levels in some selected areas in Ilorin Metropolis, Nigeria.

    Science.gov (United States)

    Oyedepo, Olayinka S; Saadu, Abdullahi A

    2009-11-01

    The noise pollution is a major problem for the quality of life in urban areas. This study was conducted to compare the noise pollution levels at busy roads/road junctions, passengers loading parks, commercial, industrial and residential areas in Ilorin metropolis. A total number of 47-locations were selected within the metropolis. Statistical analysis shows significant difference (P noise pollution levels between industrial areas and low density residential areas, industrial areas and high density areas, industrial areas and passengers loading parks, industrial areas and commercial areas, busy roads/road junctions and low density areas, passengers loading parks and commercial areas and commercial areas and low density areas. There is no significant difference (P > 0.05) in noise pollution levels between industrial areas and busy roads/road junctions, busy roads/road junctions and high density areas, busy roads/road junctions and passengers loading parks, busy roads/road junctions and commercial areas, passengers loading parks and high density areas, passengers loading parks and commercial areas and commercial areas and high density areas. The results show that Industrial areas have the highest noise pollution levels (110.2 dB(A)) followed by busy roads/Road junctions (91.5 dB(A)), Passengers loading parks (87.8 dB(A)) and Commercial areas (84.4 dB(A)). The noise pollution levels in Ilorin metropolis exceeded the recommended level by WHO at 34 of 47 measuring points. It can be concluded that the city is environmentally noise polluted and road traffic and industrial machineries are the major sources of it. Noting the noise emission standards, technical control measures, planning and promoting the citizens awareness about the high noise risk may help to relieve the noise problem in the metropolis.

  4. Advanced supersonic propulsion study. [with emphasis on noise level reduction

    Science.gov (United States)

    Sabatella, J. A. (Editor)

    1974-01-01

    A study was conducted to determine the promising propulsion systems for advanced supersonic transport application, and to identify the critical propulsion technology requirements. It is shown that noise constraints have a major effect on the selection of the various engine types and cycle parameters. Several promising advanced propulsion systems were identified which show the potential of achieving lower levels of sideline jet noise than the first generation supersonic transport systems. The non-afterburning turbojet engine, utilizing a very high level of jet suppression, shows the potential to achieve FAR 36 noise level. The duct-heating turbofan with a low level of jet suppression is the most attractive engine for noise levels from FAR 36 to FAR 36 minus 5 EPNdb, and some series/parallel variable cycle engines show the potential of achieving noise levels down to FAR 36 minus 10 EPNdb with moderate additional penalty. The study also shows that an advanced supersonic commercial transport would benefit appreciably from advanced propulsion technology. The critical propulsion technology needed for a viable supersonic propulsion system, and the required specific propulsion technology programs are outlined.

  5. Total Variation Based Parameter-Free Model for Impulse Noise Removal

    DEFF Research Database (Denmark)

    Sciacchitano, Federica; Dong, Yiqiu; Andersen, Martin Skovgaard

    2017-01-01

    We propose a new two-phase method for reconstruction of blurred images corrupted by impulse noise. In the first phase, we use a noise detector to identify the pixels that are contaminated by noise, and then, in the second phase, we reconstruct the noisy pixels by solving an equality constrained...... total variation minimization problem that preserves the exact values of the noise-free pixels. For images that are only corrupted by impulse noise (i. e., not blurred) we apply the semismooth Newton's method to a reduced problem, and if the images are also blurred, we solve the equality constrained...... reconstruction problem using a first-order primal-dual algorithm. The proposed model improves the computational efficiency (in the denoising case) and has the advantage of being regularization parameter-free. Our numerical results suggest that the method is competitive in terms of its restoration capabilities...

  6. The effect of total noise on two-dimension OCDMA codes

    Science.gov (United States)

    Dulaimi, Layth A. Khalil Al; Badlishah Ahmed, R.; Yaakob, Naimah; Aljunid, Syed A.; Matem, Rima

    2017-11-01

    In this research, we evaluate the performance of total noise effect on two dimension (2-D) optical code-division multiple access (OCDMA) performance systems using 2-D Modified Double Weight MDW under various link parameters. The impact of the multi-access interference (MAI) and other noise effect on the system performance. The 2-D MDW is compared mathematically with other codes which use similar techniques. We analyzed and optimized the data rate and effective receive power. The performance and optimization of MDW code in OCDMA system are reported, the bit error rate (BER) can be significantly improved when the 2-D MDW code desired parameters are selected especially the cross correlation properties. It reduces the MAI in the system compensate BER and phase-induced intensity noise (PIIN) in incoherent OCDMA The analysis permits a thorough understanding of PIIN, shot and thermal noises impact on 2-D MDW OCDMA system performance. PIIN is the main noise factor in the OCDMA network.

  7. Self-reported sleep disturbances due to railway noise: exposure-response relationships for nighttime equivalent and maximum noise levels.

    Science.gov (United States)

    Aasvang, Gunn Marit; Moum, Torbjorn; Engdahl, Bo

    2008-07-01

    The objective of the present survey was to study self-reported sleep disturbances due to railway noise with respect to nighttime equivalent noise level (L(p,A,eq,night)) and maximum noise level (L(p,A,max)). A sample of 1349 people in and around Oslo in Norway exposed to railway noise was studied in a cross-sectional survey to obtain data on sleep disturbances, sleep problems due to noise, and personal characteristics including noise sensitivity. Individual noise exposure levels were determined outside of the bedroom facade, the most-exposed facade, and inside the respondents' bedrooms. The exposure-response relationships were analyzed by using logistic regression models, controlling for possible modifying factors including the number of noise events (train pass-by frequency). L(p,A,eq,night) and L(p,A,max) were significantly correlated, and the proportion of reported noise-induced sleep problems increased as both L(p,A,eq,night) and L(p,A,max) increased. Noise sensitivity, type of bedroom window, and pass-by frequency were significant factors affecting noise-induced sleep disturbances, in addition to the noise exposure level. Because about half of the study population did not use a bedroom at the most-exposed side of the house, the exposure-response curve obtained by using noise levels for the most-exposed facade underestimated noise-induced sleep disturbance for those who actually have their bedroom at the most-exposed facade.

  8. Anthropogenic noise alters bat activity levels and echolocation calls

    Directory of Open Access Journals (Sweden)

    Jessie P. Bunkley

    2015-01-01

    Full Text Available Negative impacts from anthropogenic noise are well documented for many wildlife taxa. Investigations of the effects of noise on bats however, have not been conducted outside of the laboratory. Bats that hunt arthropods rely on auditory information to forage. Part of this acoustic information can fall within the spectrum of anthropogenic noise, which can potentially interfere with signal reception and processing. Compressor stations associated with natural gas extraction produce broadband noise 24 hours a day, 365 days a year. With over half a million producing gas wells in the U.S. this infrastructure is a major source of noise pollution across the landscape. We conducted a ‘natural experiment’ in the second largest gas extraction field in the U.S. to investigate the potential effects of gas compressor station noise on the activity levels of the local bat assemblage. We used acoustic monitoring to compare the activity level (number of minutes in a night with a bat call of the bat assemblage at sites with compressor stations to sites lacking this infrastructure. We found that activity levels for the Brazilian free-tailed bat (Tadarida brasiliensis were 40% lower at loud compressor sites compared to quieter well pads, whereas the activity levels of four other species (Myotis californicus, M. cillolabrum, M. lucifugus, Parastrellus hesperus were not affected by noise. Furthermore, our results reveal that the assemblage of bat species emitting low frequency (35 kHz echolocation did not exhibit altered activity levels in noise. Lower activity levels of Brazilian free-tailed bats at loud sites indicate a potential reduction in habitat for this species. Additionally, a comparison of echolocation search calls produced by free-tailed bats at sites with and without compressor stations reveal that this species modifies its echolocation search calls in noise—producing longer calls with a narrower bandwidth. Call alterations might affect prey

  9. Ambient noise levels and characterization in Aegean region, Turkey

    Science.gov (United States)

    Sevim, Fatih; Zor, Ekrem; Açıkgöz, Cem; Tarancıoğlu, Adil

    2018-03-01

    We assessed the ambient noise level in the Aegean region and analyzed its diurnal variation and its relation to the earthquake detection capability of the Aegean Region Seismic Network (ARSN). We prepared probability density functions (PDFs) for 19 broadband stations in the Aegean region operated by the Earth and Marine Sciences Institute (EMSI) of the Marmara Research Center (MRC) of the Turkish Scientific Research Council (TÜBİTAK). The power spectral densities (PSDs) used to construct PDFs for each station were computed for the periods between 0.02 and 180 s. In addition, we generated noise map of the Aegean region for different periods using the PDFs to assess the origin of the noise. We analyzed earthquake activity in the region and found that there are more local events recorded at night than during the day for each station. This difference is strongly related to diurnal variation of background noise level for the period range mostly covering the frequency range for the local events. We observed daytime noise level 15 to 20 dB higher than that at the nighttime in high frequencies for almost all stations caused by its proximity to settled areas and roads. Additionally, we observed a splitting peak within the Double Frequency (DF) microseism band; it showed a clear noise increase around the short period DF band at all the stations, decreasing inland. This peak may be related to sea waves locally generated in the Aegean Sea. We also identified a prominent increase related to marble saw companies in some stations' noise PDFs.

  10. Preparation of Ultracold Atom Clouds at the Shot Noise Level

    DEFF Research Database (Denmark)

    Gajdacz, M.; Hilliard, A. J.; Kristensen, Mick

    2016-01-01

    We prepare number stabilized ultracold atom clouds through the real-time analysis of nondestructive images and the application of feedback. In our experiments, the atom number N∼10^6 is determined by high precision Faraday imaging with uncertainty ΔN below the shot noise level, i.e., ΔN... on this measurement, feedback is applied to reduce the atom number to a user-defined target, whereupon a second imaging series probes the number stabilized cloud. By this method, we show that the atom number in ultracold clouds can be prepared below the shot noise level....

  11. Evaluation of noise pollution level in the operating rooms of hospitals: A study in Iran.

    Science.gov (United States)

    Giv, Masoumeh Dorri; Sani, Karim Ghazikhanlou; Alizadeh, Majid; Valinejadi, Ali; Majdabadi, Hesamedin Askari

    2017-06-01

    Noise pollution in the operating rooms is one of the remaining challenges. Both patients and physicians are exposed to different sound levels during the operative cases, many of which can last for hours. This study aims to evaluate the noise pollution in the operating rooms during different surgical procedures. In this cross-sectional study, sound level in the operating rooms of Hamadan University-affiliated hospitals (totally 10) in Iran during different surgical procedures was measured using B&K sound meter. The gathered data were compared with national and international standards. Statistical analysis was performed using descriptive statistics and one-way ANOVA, t -test, and Pearson's correlation test. Noise pollution level at majority of surgical procedures is higher than national and international documented standards. The highest level of noise pollution is related to orthopedic procedures, and the lowest one related to laparoscopic and heart surgery procedures. The highest and lowest registered sound level during the operation was 93 and 55 dB, respectively. Sound level generated by equipments (69 ± 4.1 dB), trolley movement (66 ± 2.3 dB), and personnel conversations (64 ± 3.9 dB) are the main sources of noise. The noise pollution of operating rooms are higher than available standards. The procedure needs to be corrected for achieving the proper conditions.

  12. Assessment of Work Zone Noise Levels at a Cement Factory in ...

    African Journals Online (AJOL)

    Assessment of Work Zone Noise Levels at a Cement Factory in Tanga, Tanzania. ... measured in most production sections exceeded the allowed limit value of 85 ... Keywords: Noise levels, Noise exposure, Cement factory, Survey, Tanzania ...

  13. The total dose effects on the 1/f noise of deep submicron CMOS transistors

    International Nuclear Information System (INIS)

    Hu Rongbin; Wang Yuxin; Lu Wu

    2014-01-01

    Using 0.18 μm CMOS transistors, the total dose effects on the 1/f noise of deep-submicron CMOS transistors are studied for the first time in mainland China. From the experimental results and the theoretic analysis, we realize that total dose radiation causes a lot of trapped positive charges in STI (shallow trench isolation) SiO 2 layers, which induces a current leakage passage, increasing the 1/f noise power of CMOS transistors. In addition, we design some radiation-hardness structures on the CMOS transistors and the experimental results show that, until the total dose achieves 750 krad, the 1/f noise power of the radiation-hardness CMOS transistors remains unchanged, which proves our conclusion. (semiconductor devices)

  14. Wideband noise observed at ground level in the auroral region

    International Nuclear Information System (INIS)

    Benson, R.F.; Desch, M.D.

    1991-01-01

    A sideband noise event was detected at ground level from the Andoya Rocket Range in Norway in January 1989. The signals were observed on four commercial communication receivers (tuned to 159, 515, 905, and 1200 kHz), an ionosonde (200-kHz to 3.5-MHz interference-free observations) and a riometer (32.5 MHz). The event, which occurred during a period of magnetic disturbance near magnetic midnight, was the only one observed during nearly 3 weeks of operations. This low frequency-of-occurrence is attributed partly to high local noise levels. The ease with which this event was identified on the ionograms produced by the local ionosonde suggests that routine ionosonde recordings should be inspected in search for such events. Such an effort would enhance existing research directed toward developing techniques for identifying quiet communication channels and help to identify the origin and frequency-of-occurrence of high-latitude wideband noise events. 20 refs

  15. modelling traffic noise level on roadside traders at wurukum market

    African Journals Online (AJOL)

    HOD

    . This leads to poor planning and traffic control strategies within the town to reduce ... embark on a study to assess the level of noise pollution .... industrial products such as cement, fuel, timber, water, waste, etc ... used for a manual traffic count.

  16. Evaluation of the environmental noise levels in Abuja Municipality ...

    African Journals Online (AJOL)

    Objectives: To assess the equivalent noise level (Leq) in Abuja municipality and promote a simple method for regular assessment of Leq within our environment. Methods: This is a cross-sectional community based study of the environmental Leq of Abuja municipality conducted between January 2014 and January 2016.

  17. The influence of subway station design on noise levels.

    Science.gov (United States)

    Shah, Ravi R; Suen, Jonathan J; Cellum, Ilana P; Spitzer, Jaclyn B; Lalwani, Anil K

    2017-05-01

    To investigate the impact of subway station design on platform noise levels. Observational. Continuous A-weighted decibel (dBA) sound levels were recorded in 20 New York City subway stations, where trains entered on either a straight track or curved track in 10 stations each. Equivalent continuous noise levels (L eq ) at various locations on the boarding platform (inbound end, midplatform, and outbound end) during train entry and exit were compared between the straight and curved stations in broadband as well as narrow one-third octave bands. Overall, curved stations trended louder than straight stations, although the difference in broadband L eq did not reach statistical significance (curve, 83.4 dBA; straight, 82.6 dBA; P = .054). Noise levels were significantly louder at the inbound end of the platform during train entry (inbound, 89.7 dBA; mid, 85.5 dBA; outbound, 78.7 dBA; P < .001) and at the outbound end during train exit (inbound, 79.7 dBA; mid, 85.3 dBA; outbound, 89.1 dBA; P < .001). Narrow band analysis showed that curved stations were significantly louder than straight stations at 100 Hz and high frequencies from 8 to 20 kHz. Peak impact levels ranged from 104 to 121 dBA. Curved stations have a different noise profile compared to straight stations and are significantly louder than straight stations at high frequencies. Designing stations with straight tracks within the platform can help reduce commuter noise exposure. NA Laryngoscope, 127:1169-1174, 2017. © 2016 The American Laryngological, Rhinological and Otological Society, Inc.

  18. Determination of the level of noise in nurseries and pre-schools and the teachers′ level of annoyance

    Directory of Open Access Journals (Sweden)

    Ozan Gokdogan

    2016-01-01

    Full Text Available Objective: The aim of this article is to determine the level of noise in nurseries and pre-schools and also to compare measured levels with standard levels and evaluate the teachers’ level of annoyance. Materials and Methods: The level of noise was measured in three different schools. A total of 162 students, whose ages were between 3 and 6 years, and 12 teachers were included the study. Every age groups’ level of noise was measured during sleeping, gaming, and eating activity. In addition, teachers’ annoyance was assessed in different age groups. Results: The 4- to 6-year-old groups were found to have higher level of sounds than 3-year-old group. Eating period was found to be the highest level of sound whereas sleeping was found the lowest. Furthermore, teachers’ annoyance was found higher as the age decreased. Conclusion: Nurseries and pre-schools have noisy environment both for the students and the teachers. High level of noise, which has bad effects on health, is a public health problem. Both the students’ families and teachers must be aware of this annoying situation.

  19. [Comfort and noise level in infants with helmet interface].

    Science.gov (United States)

    Medina, A; Alvarez Fernández, P; Rey Galán, C; Álvarez Mendiola, P; Álvarez Blanco, S; Vivanco Allende, A

    2015-10-01

    To evaluate comfort and noise intensity using the COMFORT scale in infants who receive respiratory support with a helmet interface. An observational descriptive study was conducted on all infants (1 to 12 months of age) admitted to a PICU from November 1st 2013 to March 31st 2014 and who received non-invasive ventilation with a helmet interface. Tolerance to the interface was assessed by use of the COMFORT scale. The intensity of the noise to which the infants were exposed was measured with a TES1350A HIBOK 412 sound-level meter. Three measurements were made every day. Twenty seven patients with bronchiolitis (median age: 54 days; range: 10 to 256) were included. Median COMFORT score in the first day was 21 points (14 - 28). An increase in patient comfort was found with a gradual decrease in the scores, with a maximum reduction of 22% from the first hours (score of 22) to the fifth day (score of 18). The minimum sound intensity registered was 42dB, and the maximum was 78dB. Background noise intensity was associated with noise intensity in the helmet. No differences were observed in COMFORT score and noise intensity between ventilator devices. Helmet interface was well tolerated by infants. COMFORT score results are an indicator that infants were comfortable or very comfortable. The measured noise intensity was in the safe range permitted by World Health Organization. Copyright © 2014 Asociación Española de Pediatría. Published by Elsevier España, S.L.U. All rights reserved.

  20. Photonic microwave signals with zeptosecond-level absolute timing noise

    Science.gov (United States)

    Xie, Xiaopeng; Bouchand, Romain; Nicolodi, Daniele; Giunta, Michele; Hänsel, Wolfgang; Lezius, Matthias; Joshi, Abhay; Datta, Shubhashish; Alexandre, Christophe; Lours, Michel; Tremblin, Pierre-Alain; Santarelli, Giorgio; Holzwarth, Ronald; Le Coq, Yann

    2017-01-01

    Photonic synthesis of radiofrequency (RF) waveforms revived the quest for unrivalled microwave purity because of its ability to convey the benefits of optics to the microwave world. In this work, we perform a high-fidelity transfer of frequency stability between an optical reference and a microwave signal via a low-noise fibre-based frequency comb and cutting-edge photodetection techniques. We demonstrate the generation of the purest microwave signal with a fractional frequency stability below 6.5 × 10-16 at 1 s and a timing noise floor below 41 zs Hz-1/2 (phase noise below -173 dBc Hz-1 for a 12 GHz carrier). This outperforms existing sources and promises a new era for state-of-the-art microwave generation. The characterization is achieved through a heterodyne cross-correlation scheme with the lowermost detection noise. This unprecedented level of purity can impact domains such as radar systems, telecommunications and time-frequency metrology. The measurement methods developed here can benefit the characterization of a broad range of signals.

  1. The effect of total noise on two-dimension OCDMA codes

    Directory of Open Access Journals (Sweden)

    Khalil Al Dulaimi Layth A.

    2017-01-01

    Full Text Available In this research, we evaluate the performance of total noise effect on two dimension (2-D optical code-division multiple access (OCDMA performance systems using 2-D Modified Double Weight MDW under various link parameters. The impact of the multi-access interference (MAI and other noise effect on the system performance. The 2-D MDW is compared mathematically with other codes which use similar techniques. We analyzed and optimized the data rate and effective receive power. The performance and optimization of MDW code in OCDMA system are reported, the bit error rate (BER can be significantly improved when the 2-D MDW code desired parameters are selected especially the cross correlation properties. It reduces the MAI in the system compensate BER and phase-induced intensity noise (PIIN in incoherent OCDMA The analysis permits a thorough understanding of PIIN, shot and thermal noises impact on 2-D MDW OCDMA system performance. PIIN is the main noise factor in the OCDMA network.

  2. Noise exposure levels for musicians during rehearsal and performance times.

    Science.gov (United States)

    McIlvaine, Devon; Stewart, Michael; Anderson, Robert

    2012-03-01

    The purpose of this study was to determine daily noise doses and 8-hour time weighted averages for rock band musicians, crew members, and spectators during a typical rehearsal and performance using both Occupational Safety and Health Administration (OSHA) and National Institute of Occupational Safety and Health (NIOSH) measurement criteria. Personal noise dosimetry was completed on five members of a rock band during one 2-hr rehearsal and one 4-hr performance. Time-weighted averages (TWA) and daily dose values were calculated using both OSHA and NIOSH criteria and compared to industry guidelines for enrollment in hearing conservation programs and the use of hearing protection devices. TWA values ranged from 84.3 to 90.4 dBA (OSHA) and from 90.0 to 96.4 dBA (NIOSH) during the rehearsal. The same values ranged from 91.0 to 99.7 dBA (OSHA) and 94.0 to 102.8 dBA (NIOSH) for the performance. During the rehearsal, daily noise doses ranged from 45.54% to 106.7% (OSHA) and from 317.74% to 1396.07% (NIOSH). During the performance, doses ranged from 114.66% to 382.49% (OSHA) and from 793.31% to 5970.15% (NIOSH). The musicians in this study were exposed to dangerously high levels of noise and should be enrolled in a hearing conservation programs. Hearing protection devices should be worn, especially during performances. The OSHA measurement criteria yielded values significantly more conservative than those produced by NIOSH criteria. Audiologists should counsel musician-patients about the hazards of excessive noise (music) exposure and how to protect their hearing.

  3. Measurement of Acceptable Noise Level with Background Music.

    Science.gov (United States)

    Ahn, Hyun-Jung; Bahng, Junghwa; Lee, Jae Hee

    2015-09-01

    Acceptable noise level (ANL) is a measure of the maximum background noise level (BNL) that a person is willing to tolerate while following a target story. Although researchers have used various sources of target sound in ANL measures, a limited type of background noise has been used. Extending the previous study of Gordon-Hickey & Moore (2007), the current study determined the effect of music genre and tempo on ANLs as possible factors affecting ANLs. We also investigated the relationships between individual ANLs and the familiarity of music samples and between music ANLs and subjective preference. Forty-one participants were seperated into two groups according to their ANLs, 29 low-ANL listeners and 12 high-ANL listeners. Using Korean ANL material, the individual ANLs were measured based on the listeners' most comfortable listening level and BNL. The ANLs were measured in six conditions, with different music tempo (fast, slow) and genre (K-pop, pop, classical) in a counterbalanced order. Overall, ANLs did not differ by the tempo of background music, but music genre significantly affected individual ANLs. We observed relatively higher ANLs with K-pop music and relatively lower ANLs with classical music. This tendency was similar in both low-ANL and high-ANL groups. However, the subjective ratings of music familiarity and preference affected ANLs differently for low-ANL and high-ANL groups. In contrast to the low-ANL listeners, the ANLs of the high-ANL listeners were significantly affected by music familiarity and preference. The genre of background music affected ANLs obtained using background music. The degree of music familiarity and preference appears to be associated with individual susceptibility to background music only for listeners who are greatly annoyed by background noise (high-ANL listeners).

  4. Evaluation of noise level at intensive care units in selected hospitals of Sanandaj

    Directory of Open Access Journals (Sweden)

    Nammam Ali Azadi

    2015-08-01

    Conclusion: We found the noise levels were always above the EPA thresholds at all three hospitals both during the day and night. It is recommended to train hospital officials and staffs for keeping noise levels to an acceptable level.

  5. Subjective annoyance caused by indoor low-level and low frequency noise and control method

    Institute of Scientific and Technical Information of China (English)

    DI Guo-qing; ZHANG Bang-jun; SHANG Qi

    2005-01-01

    The influence of low-level noise has not been widely noticed. This paper discovered that low-level and low frequency noise(Aweighted equivalent level Leq < 45 dB) causes higher probability of subjective annoyance. The fuzzy mathematic principle was applied to deal with the threshold level of subjective annoyance from noise in this study; there is preferable relationship between the indoor noise and noise annoyance at low frequency noise level. Study indicated at the same centered noise level, the change of annoyance probability is mainly caused by the change of the frequency spectrum characteristic of the indoor noise. Under low noise level environment, without change of the medium-low frequency noise, the slight increase of medium-high frequency noise level with the help of noise sheltering effect can significantly reduce the noise annoyance. This discovery brings a new resolution on how to improve the environmental quality of working or living places. A noise control model is given in this study according to the acoustic analysis.

  6. 33 CFR 149.697 - What are the requirements for a noise level survey?

    Science.gov (United States)

    2010-07-01

    ... and Equipment Noise Limits § 149.697 What are the requirements for a noise level survey? (a) A survey... measured over 12 hours to derive a time weighted average (TWA) using a sound level meter and an A-weighted filter or equivalent device. (c) If the noise level throughout a space is determined to exceed 85 db(A...

  7. Noise

    Science.gov (United States)

    Noise is all around you, from televisions and radios to lawn mowers and washing machines. Normally, you ... sensitive structures of the inner ear and cause noise-induced hearing loss. More than 30 million Americans ...

  8. The Analysis of Low Noise Protection Barriers Influence on Tram Traffic Noise Levels

    Directory of Open Access Journals (Sweden)

    Ahac Maja

    2013-07-01

    Full Text Available The paper describes the analysis of tram traffic noise situation in residential areas in the vicinity of Drzic Avenue, one of the major routes between the northern and southern part of the Croatian capital city Zagreb, and the effect of low barriers placed by the tracks on tram noise mitigation. In order to evaluate the effect of planned protection measure, noise models were produced and verified with short-term field measurements. Calculations were conducted by means of noise prediction software, using European interim noise prediction method and 3D model of analyzed area. Finally, the results of noise calculations for existing tram traffic situation and planned measure of protection are presented on noise maps.

  9. Noise levels from toys and recreational articles for children and teenagers.

    Science.gov (United States)

    Hellstrom, P A; Dengerink, H A; Axelsson, A

    1992-10-01

    This study examined the noise level emitted by toys and recreational articles used by children and teenagers. The results indicate that many of the items tested emit sufficiently intense noise to be a source of noise induced hearing loss in school-age children. While the baby toys provided noise exposure within the limits of national regulations, they are most intense in a frequency range that corresponds to the resonance frequency of the external auditory canal of very young children. Hobby motors emit noise that may require protection depending upon the length of use. Fire-crackers and cap guns emit impulse noises that exceed even conservative standards for noise exposure.

  10. Statistics of A-weighted road traffic noise levels in shielded urban areas

    NARCIS (Netherlands)

    Forssén, J.; Hornikx, M.C.J.

    2006-01-01

    In the context of community noise and its negative effects, the noise descriptors used are usually long-term equivalent levels and, sometimes, maximum levels. An improved description could be achieved by including the time variations of the noise. Here, the time variations of A-weighted road traffic

  11. Noise Levels in Two Emergency Departments Before and After the Introduction of Electronic Whiteboards

    DEFF Research Database (Denmark)

    Hertzum, Morten

    2013-01-01

    . The maximum equivalent continuous noise levels across 1 second were above 80 dB(A) at all four coordination centres. At two of the centres above 80 dB(A) noises also occurred at night. After the introduction of electronic whiteboards the noise level was lowered at one ED but unchanged at the other ED...

  12. Assessment of ambient noise levels in the intensive care unit of a university hospital

    Directory of Open Access Journals (Sweden)

    Hatem O Qutub

    2009-01-01

    Conclusion : Some sources of environmental noise, such as the use of oxygen, suction equipment or respirators are unavoidable. Nevertheless, hospital ICUs should have measures to minimize the level of exposure to noise in the ICU. Further research in this area might focus on the noise level and other modifiable environmental stress factors in the ICU that affect patients as well as the staff.

  13. Noise sensitivity, rather than noise level, predicts the non-auditory effects of noise in community samples: a population-based survey

    Directory of Open Access Journals (Sweden)

    Jangho Park

    2017-04-01

    Full Text Available Abstract Background Excessive noise affects human health and interferes with daily activities. Although environmental noise may not directly cause mental illness, it may accelerate and intensify the development of latent mental disorders. Noise sensitivity (NS is considered a moderator of non-auditory noise effects. In the present study, we aimed to assess whether NS is associated with non-auditory effects. Methods We recruited a community sample of 1836 residents residing in Ulsan and Seoul, South Korea. From July to November 2015, participants were interviewed regarding their demographic characteristics, socioeconomic status, medical history, and NS. The non-auditory effects of noise were assessed using the Center of Epidemiologic Studies Depression, Insomnia Severity index, State Trait Anxiety Inventory state subscale, and Stress Response Inventory-Modified Form. Individual noise levels were recorded from noise maps. A three-model multivariate logistic regression analysis was performed to identify factors that might affect psychiatric illnesses. Results Participants ranged in age from 19 to 91 years (mean: 47.0 ± 16.1 years, and 37.9% (n = 696 were male. Participants with high NS were more likely to have been diagnosed with diabetes and hyperlipidemia and to use psychiatric medication. The multivariable analysis indicated that even after adjusting for noise-related variables, sociodemographic factors, medical illness, and duration of residence, subjects in the high NS group were more than 2 times more likely to experience depression and insomnia and 1.9 times more likely to have anxiety, compared with those in the low NS group. Noise exposure level was not identified as an explanatory value. Conclusions NS increases the susceptibility and hence moderates there actions of individuals to noise. NS, rather than noise itself, is associated with an elevated susceptibility to non-auditory effects.

  14. Potential of neuro-fuzzy methodology to estimate noise level of wind turbines

    Science.gov (United States)

    Nikolić, Vlastimir; Petković, Dalibor; Por, Lip Yee; Shamshirband, Shahaboddin; Zamani, Mazdak; Ćojbašić, Žarko; Motamedi, Shervin

    2016-01-01

    Wind turbines noise effect became large problem because of increasing of wind farms numbers since renewable energy becomes the most influential energy sources. However, wind turbine noise generation and propagation is not understandable in all aspects. Mechanical noise of wind turbines can be ignored since aerodynamic noise of wind turbine blades is the main source of the noise generation. Numerical simulations of the noise effects of the wind turbine can be very challenging task. Therefore in this article soft computing method is used to evaluate noise level of wind turbines. The main goal of the study is to estimate wind turbine noise in regard of wind speed at different heights and for different sound frequency. Adaptive neuro-fuzzy inference system (ANFIS) is used to estimate the wind turbine noise levels.

  15. The Effect of the Cholesterol Levels on Noise-Induced Hearing Loss.

    Science.gov (United States)

    Demir, Mehmet Gokhan; Aydin, Sedat

    2018-01-01

    Introduction  Noise-induced hearing loss (NIHL), which is one of the most common occupational diseases among industrialized populations, is associated with longstanding exposure to high levels of noise. The pathogenesis of NIHL is not clear, but some genes and their activity at the tissue level have been investigated. Hypercholesterolemia, which can disturb the microcirculation, can be one of the underlying pathologies in hearing loss. Objective  To investigate the relationship between NIHL and hypercholesterolemia. Methods  The study group was selected among workers who had an occupational exposure of 85 dB of noise for at least 10 years. The audiologic assessment was recorded at seven frequencies (500 Hz, 1,000 Hz, 2,000 Hz, 3,000 Hz, 4,000 Hz, 6,000 Hz and 8,000 Hz). A total of 456 workers were included in the study and divided into two groups: the control group (252 patients) and the NIHL group (204 patients). After the audiologic measurement, blood samples were taken and investigated for blood cholesterol levels. According to these results, the groups were compared. Results  Both groups were similarly distributed regarding age and occupational exposure time ( p  > 0.05). We could not detect any association between cholesterol levels and noise-induced hearing loss ( p   0.05). Conclusion  Noise-induced hearing loss is still a common occupational problem that can be prevented by hearing conservation programs and occupational health and safety training. Still, we know little about the relationship between NIHL and hypercholesterolemia. According to our findings, we cannot detect any relationship. Controlled studies and studies with human individuals can be made possible in the future with diagnostic innovations in tissue imaging and tissue microcircular sampling.

  16. Effects of self-reported sensitivity and road-traffic noise levels on the immune system.

    Directory of Open Access Journals (Sweden)

    Ahra Kim

    Full Text Available Sensitivity to noise, particularly road traffic noise, can increase cortisol levels and result in changes in immune system biomarkers. Therefore, continuous exposure to noise can have an effect on immune function, hormonal levels, and cardiovascular function, leading to hypertension and stress. The purpose of this study was to investigate the changes in stress-and immune system-related biomarkers according to the self-reported sensitivity to noise and exposure to road traffic noise, to ultimately determine the potential effects of noise on health. A survey was conducted through questionnaire (ISO/TS 15666 sent to 172 female subjects in Korea, including 128 from Ulsan and 44 from Seoul. The average noise level was calculated, and blood samples were collected for measurements of cortisol levels, Natural killer (NK / Natural killer T (NKT cell populations, and NK cell activity (through measurements of interleukin-12 (IL-12 and interferon-gamma (INF-γ concentrations. Multivariate linear regression analysis of the measured biomarkers according to the road traffic noise level and self-reported noise sensitivity was conducted adjusting for the effects of age, alcohol status, smoking status, regular exercise, and residence period. IL-12 levels increased, whereas the NKT cell population decreased with increasing noise levels. The results further suggested that cortisol levels are more influenced by the subject's sensitivity to noise than to the level of chronic road traffic noise. Therefore, noise appears to have the largest effect on IL-12 levels as well as the population and activity of NKT cells. In conclusion, our results suggest that low-level road traffic noise and sensitivity to noise can affect health by causing changes in the immune response through mechanisms other than increased cortisol.

  17. Projected contributions of future wind farm development to community noise and annoyance levels in Ontario, Canada

    International Nuclear Information System (INIS)

    Whitfield Aslund, Melissa L.; Ollson, Christopher A.; Knopper, Loren D.

    2013-01-01

    Wind turbines produce sound during their operation; therefore, jurisdictions around the world have developed regulations regarding the placement of electricity generating wind farms with the intent of preventing unacceptable levels of ‘community noise’ in their vicinity. However, as survey results indicate that the relationship between wind turbine noise and annoyance may differ from noise-annoyance relationships for other common noise sources (e.g., rail, traffic), there are concerns that the application of general noise guidelines for wind turbines may lead to unacceptably high levels of annoyance in communities. In this study, previously published survey results that quantified wind turbine noise and self-reported annoyance were applied to the predicted noise levels (from turbines and transformers) for over 8000 receptors in the vicinity of 13 planned wind power developments in the province of Ontario, Canada. The results of this analysis indicate that the current wind turbine noise restrictions in Ontario will limit community exposure to wind turbine related noise such that levels of annoyance are unlikely to exceed previously established background levels of noise-related annoyance from other common noise sources. This provides valuable context that should be considered by policy-makers when evaluating the potential impacts of wind turbine noise on the community. -- highlights: •Wind turbine noise-annoyance relationship used to predict annoyance in Ontario. •Noise annoyance predicted to be <8% for non-participants <1 km from turbines. •Predicted levels of wind turbine noise annoyance similar to that from traffic noise. •Wind turbine noise annoyance not expected to exceed existing background levels

  18. Anthropogenic noise alters bat activity levels and echolocation calls

    OpenAIRE

    Bunkley, Jessie P.; McClure, Christopher J.W.; Kleist, Nathan J.; Francis, Clinton D.; Barber, Jesse R.

    2015-01-01

    Negative impacts from anthropogenic noise are well documented for many wildlife taxa. Investigations of the effects of noise on bats however, have not been conducted outside of the laboratory. Bats that hunt arthropods rely on auditory information to forage. Part of this acoustic information can fall within the spectrum of anthropogenic noise, which can potentially interfere with signal reception and processing. Compressor stations associated with natural gas extraction produce broadband nois...

  19. Noise level in neonatal incubators: A comparative study of three models.

    Science.gov (United States)

    Fernández Zacarías, F; Beira Jiménez, J L; Bustillo Velázquez-Gaztelu, P J; Hernández Molina, R; Lubián López, Simón

    2018-04-01

    Preterm infants usually have to spend a long time in an incubator, excessive noise in which can have adverse physiological and psychological effects on neonates. In fact, incubator noise levels typically range from 45 to 70 dB but differences in this respect depend largely on the noise measuring method used. The primary aim of this work was to assess the extent to which noise in an incubator comes from its own fan and how efficiently the incubator can isolate external noise. Three different incubator models were characterized for acoustic performance by measuring their internal noise levels in an anechoic chamber, and also for noise isolation efficiency by using a pink noise source in combination with an internal and an external microphone that were connected to an SVAN958 noise analyzer. The incubators studied produced continuous equivalent noise levels of 53.5-58 dB and reduced external noise by 5.2-10.4 dB. A preterm infant in an incubator is exposed to noise levels clearly exceeding international recommendations even though such levels usually comply with the limit set in the standard IEC60601-2-19: 2009 (60 dBA) under normal conditions of use. Copyright © 2018. Published by Elsevier B.V.

  20. Evaluation of noise levels in manufacturing sectors in Thika district ...

    African Journals Online (AJOL)

    Noise is considered as any unwanted sound that may adversely affect the health and wellbeing of individuals or populations exposed. This study assessed the magnitude of occupational noise exposures to workers in different manufacturing sectors in Thika District‐Kenya. Systematic random sampling was used to select 8 ...

  1. A study investigating sound sources and noise levels in neonatal ...

    African Journals Online (AJOL)

    Background. Exposure to noise in the neonatal intensive care unit (NICU) has the potential to affect neonatal auditory development, sleep patterns and physiological stability, thus impacting on developmental progress. Objectives. This study aimed to identify noise sources in three NICUs in Johannesburg, South Africa, and ...

  2. [Equivalent continuous noise level in neonatal intensive care unit associated to burnout syndrome].

    Science.gov (United States)

    Garrido Galindo, A P; Camargo Caicedo, Y; Vélez-Pereira, A M

    2015-01-01

    Noise levels in neonatal intensive care units allow the appearance of symptoms associated with burnout such as stress, irritability, fatigue and emotional instability on health care personnel. The aim of this study was to evaluate the equivalent continuous noise levels in the neonatal intensive care unit and compare the results with noise levels associated with the occurrence of burnout syndrome on the care team. Continuous sampling was conducted for 20 days using a type I sound level meter on the unit. The maximum, the ninetieth percentile and the equivalent continuous noise level (Leq) values were recorded. Noise level is reported in the range of 51.4-77.6 decibels A (dBA) with an average of 64 dBA, 100.6 dBA maximum, and average background noise from 57.9 dBA. Noise levels exceed the standards suggested for neonatal intensive care units, are close to maximum values referred for noise exposure in the occupational standards and to noise levels associated with the onset of burnout; thus allowing to infer the probability of occurrence of high levels of noise present in the unit on the development of burnout in caregivers. Copyright © 2013 Elsevier España, S.L.U. y SEEIUC. All rights reserved.

  3. Variations in the microseismic noise level observed at the Bucovina Seismic Array (BURAR)

    International Nuclear Information System (INIS)

    Ghica, Daniela; Radulian, Mircea; Popa, Mihaela

    2005-01-01

    The microseismic noise level analysis for a seismic array is an essential step to accurately process the data recorded by the system. Basically, the observed background noise is a complex combination of natural and cultural sources as local geology, specific area activity (roads traffic, agricultural and industrial activities) or weather conditions.The understanding of the BURAR site noise characteristics is important for the array specific techniques (beamforming, f-k analysis), to apply the correct bandpass filtering, in order to obtain noise suppression and conservation of the 'true' seismic signal. The array monitoring potential of very small earthquakes and explosions will be enhanced, based on the best signal-to-noise ratio.The noise study at BURAR was carried out over one-year period, considering the noise power spectra in a 0.1 to 10 Hz frequency interval, for every 24 hours: 5 minutes during day and 5 minutes during night. Only short-period vertical sensors were considered. Systematic variations in the microseismic noise level at the BURAR site were observed:- diurnal: a decreasing of about 40% in night noise level at 1 Hz frequency; at 6 Hz frequency, the decreasing could reach 80-90% for 'non-winter' months (May to October); - seasonal: during the winter time, a lower noise level is observed, due to the restraining of the local specific activity (especially agriculture and farming) and of the road traffic. To summarize the level of microseismic noise observed at BURAR for one-year observations, a model curve for array noise level has been estimated, including upper and lower bounds of noise power density together with average spectrum. The BURAR noise model will be useful in the process of local site conditions estimation, by eliminating the noise contribution from the array recording. Also, the detection processing, phase identification and events location procedures will be significantly improved. (authors)

  4. Fast noise level estimation algorithm based on principal component analysis transform and nonlinear rectification

    Science.gov (United States)

    Xu, Shaoping; Zeng, Xiaoxia; Jiang, Yinnan; Tang, Yiling

    2018-01-01

    We proposed a noniterative principal component analysis (PCA)-based noise level estimation (NLE) algorithm that addresses the problem of estimating the noise level with a two-step scheme. First, we randomly extracted a number of raw patches from a given noisy image and took the smallest eigenvalue of the covariance matrix of the raw patches as the preliminary estimation of the noise level. Next, the final estimation was directly obtained with a nonlinear mapping (rectification) function that was trained on some representative noisy images corrupted with different known noise levels. Compared with the state-of-art NLE algorithms, the experiment results show that the proposed NLE algorithm can reliably infer the noise level and has robust performance over a wide range of image contents and noise levels, showing a good compromise between speed and accuracy in general.

  5. Industrial noise level study in a wheat processing factory in ilorin, nigeria

    Science.gov (United States)

    Ibrahim, I.; Ajao, K. R.; Aremu, S. A.

    2016-05-01

    An industrial process such as wheat processing generates significant noise which can cause adverse effects on workers and the general public. This study assessed the noise level at a wheat processing mill in Ilorin, Nigeria. A portable digital sound level meter HD600 manufactured by Extech Inc., USA was used to determine the noise level around various machines, sections and offices in the factory at pre-determined distances. Subjective assessment was also mode using a World Health Organization (WHO) standard questionnaire to obtain information regarding noise ratings, effect of noise on personnel and noise preventive measures. The result of the study shows that the highest noise of 99.4 dBA was recorded at a pressure blower when compared to other machines. WHO Class-4 hearing protector is recommended for workers on the shop floor and room acoustics should be upgraded to absorb some sounds transmitted to offices.

  6. Evaluation of noise level in architecture department building in University of Sumatera Utara

    Science.gov (United States)

    Amran, Novrial; Damanik, Novita Hillary Christy

    2018-03-01

    Noise is one the comfort factors that need to be noticed, particularly in an educational environment. Hearing a high noise in a period can affect students’ learning performance. The aims of this study were to know the noise level and get an appropriate design to reduce noise in Architecture Department building in the University of Sumatera Utara, considering that architecture students often spend most of their time inside the room. The measurement was conducted in four rooms for two days each from 09:00 – 12:00 and from 13:00 – 16:00 by using Sound Level Meter that placed near the noise source of the room. The result indicated that the average of noise level exceeded the 55 dB(A) so it still needs the appropriate design to reduce the noise that occurs in the building.

  7. Decreased total antioxidant levels and increased oxidative stress in ...

    African Journals Online (AJOL)

    21–25 ... Decreased total antioxidant levels and increased oxidative stress in South ... antioxidant-rich diet and lifestyle changes in T2DM patients would help to avert the .... glycation of proteins and the formation of advanced glycosylation.

  8. Assessment of noise level and noise propagation generated by light-lift helicopters in mountain natural environments.

    Science.gov (United States)

    Grigolato, Stefano; Mologni, Omar; Proto, Andrea Rosario; Zimbalatti, Giuseppe; Cavalli, Raffaele

    2018-01-20

    The use of helicopter rises discussion about environmental noise propagation especially when it operates in proximity of environmentally sensitive areas (ESAs) for an extended period because of its potential implications in wildlife behaviours. In order to support decisions on helicopter logging operation management in proximity of ESAs, this study focused on (i) analysing the noise spectrum of a light-lift helicopter during logging operations and on (ii) assessing the noise propagation in the surrounding environments. This study investigated a helicopter logging operation for wood fuel extraction in the eastern part of the Italian Alps. The potential disturbance area covered for the entire helicopter logging operation was evaluated by a specific GIS application according to hearing sensitivity of the most sensitive wildlife species in the study area (different strigiform species). The noise level at the ground appeared to be affected by the location regardless both the use of equivalent continuous sound pressures level dB(A) (LAeq) and the single-event level (SEL) noise metrics. The lowest values were recorded when the helicopter was flown over the sound meter level located under the forest canopy, while the highest was recorded when the helicopter was unhooking the loads at the landing. The GIS application highlighted the consistent of the exceeded noise area (weighted to strigiform hearing range and sensitivity) for the lower frequency bands (0.016-0.250 kHz). A more restricted exceeded noise area concerned instead the most sensitive frequency bands" for the strigiform (1-2 kHz). Graphical abstract ᅟ.

  9. ASSESSMENT OF WORK ZONE NOISE LEVELS AT A CEMENT ...

    African Journals Online (AJOL)

    Osondu

    2012-03-24

    Mar 24, 2012 ... in various production sections at a cement factory in Tanga, Tanzania and assess attitudes of ... Ethiopian Journal of Environmental Studies and Management EJESM Vol. 5 No ..... exposure, Handbook of Noise Control, Harris,.

  10. A study investigating sound sources and noise levels in neonatal

    African Journals Online (AJOL)

    in Asia and sub-Saharan Africa accounting for 60% ... to identify and evaluate environmental stressors in the NICU, and to ... The findings have important implications for neonatal care, and highlight the importance of noise reduction and ...

  11. I'm trying to heal...noise levels in a pediatric intensive care unit.

    Science.gov (United States)

    Milette, Isabelle H; Carnevale, Franco A

    2003-01-01

    The literature demonstrates clearly that most intensive care units exceed the standard recommendations for noise levels in hospitals, and that high noise levels have negative impacts on patients and staff. The purpose of this study was to evaluate the level of noise in a PICU and compare it to the recommendations of international bodies. We outline recommendations to promote the awareness of this problem and suggest strategies to decrease the level of noise in a PICU. The orientations of these strategies are threefold: 1) architectural-acoustic design, 2) equipment design and, most importantly, 3) staff education.

  12. Traffic background level and signal duration effects on aircraft noise judgment

    Energy Technology Data Exchange (ETDEWEB)

    Johnston, G W; Haasz, A A

    1977-04-22

    The effects of background traffic noise level and signal duration on perceived aircraft noise levels during a flyover event are investigated. Tapes of traffic noise at different levels on which aircraft flyover noise events of different durations were superimposed were played to groups of observers in a room simulating indoor conditions. It is found that the presence of steady background traffic noise reduces the perceived noisiness of aircraft flyovers provided that the duration of the flyover event is sufficiently short in relation to flyover time. For a given event level, a reduction of 21 dB(A) in background noise level leads to the perception of a 5.5 dB(A) increase in peak event level. Regressions of observer response with the noise pollution index show a lower correlation than those with variables based on background noise level and peak signal level, although the data are found to exhibit a number of significant trends associated with noise pollution index variations.

  13. Noise-level determination for discrete spectra with Gaussian or Lorentzian probability density functions

    International Nuclear Information System (INIS)

    Moriya, Netzer

    2010-01-01

    A method, based on binomial filtering, to estimate the noise level of an arbitrary, smoothed pure signal, contaminated with an additive, uncorrelated noise component is presented. If the noise characteristics of the experimental spectrum are known, as for instance the type of the corresponding probability density function (e.g., Gaussian), the noise properties can be extracted. In such cases, both the noise level, as may arbitrarily be defined, and a simulated white noise component can be generated, such that the simulated noise component is statistically indistinguishable from the true noise component present in the original signal. In this paper we present a detailed analysis of the noise level extraction when the additive noise is Gaussian or Lorentzian. We show that the statistical parameters in these cases (mainly the variance and the half width at half maximum, respectively) can directly be obtained from the experimental spectrum even when the pure signal is erratic. Further discussion is given for cases where the noise probability density function is initially unknown.

  14. Analysis of noise pollution level in a University campus in South India

    Science.gov (United States)

    Thattai, D.; Sudarsan, J. S.; Sathyanathan, R.; Ramasamy, Visalatchi

    2017-07-01

    Noise comprises those sounds occurring around us that are not part of the environment under consideration. Noise is also a type of pollution and impacts on our health and wellness. The prevalence of noise is increasing in magnitude and severity because of growing population and urbanization. Noise pollution leads to many chronic and socially significant impacts. This study analyzes the level of noise at different points in SRM University. As the University encompasses a hospital also, it is more important to identify the sources of high noise levels and control them. As per Indian standards the desirable noise pollution for educational institutions and hospitals in daytime is 50 dbA. Noise levels were measured with a sound level meter at 19 points within the campus at three different timings (8-10 am, 12-2 pm, and 3-5 pm) over two cycles of measurements. The preliminary results show higher noise levels during morning and evening. Noise during Cycle 2 (latter half of semester) was 20% more compared to that of Cycle 1 (beginning of semester).

  15. Methods For an Acceptable Traffic Noise Level Design

    Directory of Open Access Journals (Sweden)

    Zlatko Sviben

    2004-07-01

    Full Text Available Road noise disturbance on rough roads by means of loudnesssensor caused by wideband signal components with a significantimpact of tonal effects on smooth roads and in specificactions in driving lead to the annoyance of drivers. A systemicapproach has been applied for the sound quality estimation ofphysical properties of various noise sources and structuralvibroacoustic car properties and its components as an integratedparameter in car design for the purpose of the developmentand vehicle noise reduction. Simulation of the most importantcharacteristics of listening impressions was performedby modem systems of signal analysis together with the presentationof loudness, sharpness, and roughness as essential quantities.Optimization of the noise control measuring regarding vehiclesound was obtained by means of a simulation system withthe capability of the real time original sound filtering. Structuralanalysis was performed as an acoustic modal analysis on therear part and the car interior with the quantitative analysis ofsport and luxury car sounds. The possibility of active noise controlwas studied and examples are given for an application ofpsychoacoustic tools for car sound quality design. Sound qualitywas obtained by an observation of certain aspects, which areempirically or theoretically connected with the design. An experimentalsound synthesis with psychometrical measuring wasapplied. The sound quality of car interior is presented takinginto consideration the criteria of objectivity, reliability and validity.

  16. Detection System of Sound Noise Level (SNL) Based on Condenser Microphone Sensor

    Science.gov (United States)

    Rajagukguk, Juniastel; Eka Sari, Nurdieni

    2018-03-01

    The research aims to know the noise level by using the Arduino Uno as data processing input from sensors and called as Sound Noise Level (SNL). The working principle of the instrument is as noise detector with the show notifications the noise level on the LCD indicator and in the audiovisual form. Noise detection using the sensor is a condenser microphone and LM 567 as IC op-amps, which are assembled so that it can detect the noise, which sounds are captured by the sensor will turn the tide of sinusoida voice became sine wave energy electricity (altering sinusoida electric current) that is able to responded to complaints by the Arduino Uno. The tool is equipped with a detector consists of a set indicator LED and sound well as the notification from the text on LCD 16*2. Work setting indicators on the condition that, if the measured noise > 75 dB then sound will beep, the red LED will light up indicating the status of the danger. If the measured value on the LCD is higher than 56 dB, sound indicator will be beep and yellow LED will be on indicating noisy. If the noise measured value <55 dB, sound indicator will be quiet indicating peaceful from noisy. From the result of the research can be explained that the SNL is capable to detecting and displaying noise level with a measuring range 50-100 dB and capable to delivering the notification noise in audiovisual.

  17. Noise levels of neonatal high-flow nasal cannula devices--an in-vitro study.

    Science.gov (United States)

    König, Kai; Stock, Ellen L; Jarvis, Melanie

    2013-01-01

    Excessive ambient noise levels have been identified as a potential risk factor for adverse outcome in very preterm infants. Noise level measurements for continuous positive airway pressure (CPAP) devices demonstrated that these constantly exceed current recommendations. The use of high-flow nasal cannula (HFNC) as an alternative non-invasive ventilation modality has become more popular in recent years in neonatal care. To study noise levels of two HFNC devices commonly used in newborns. As a comparison, noise levels of a continuous flow CPAP device were also studied. In-vitro study. The noise levels of two contemporary HFNC devices (Fisher & Paykel NHF™ and Vapotherm Precision Flow®) and one CPAP device (Dräger Babylog® 8000 plus) were measured in the oral cavity of a newborn manikin in an incubator in a quiet environment. HFNC flows of 4-8 l/min and CPAP pressures of 4-8 cm H2O were applied. The CPAP flow was set at 8 l/min as per unit practice. Vapotherm HFNC generated the highest noise levels, measuring 81.2-91.4 dB(A) with increasing flow. Fisher & Paykel HFNC noise levels were between 78.8 and 81.2 dB(A). The CPAP device generated the lowest noise levels between 73.9 and 77.4 dB(A). Both HFNC devices generated higher noise levels than the CPAP device. All noise levels were far above current recommendations of the American Academy of Pediatrics. In light of the long duration of non-invasive respiratory support of very preterm infants, less noisy devices are required to prevent the potentially adverse effects of continuing excessive noise exposure in the neonatal intensive care unit. Copyright © 2013 S. Karger AG, Basel.

  18. A noise level prediction method based on electro-mechanical frequency response function for capacitors.

    Science.gov (United States)

    Zhu, Lingyu; Ji, Shengchang; Shen, Qi; Liu, Yuan; Li, Jinyu; Liu, Hao

    2013-01-01

    The capacitors in high-voltage direct-current (HVDC) converter stations radiate a lot of audible noise which can reach higher than 100 dB. The existing noise level prediction methods are not satisfying enough. In this paper, a new noise level prediction method is proposed based on a frequency response function considering both electrical and mechanical characteristics of capacitors. The electro-mechanical frequency response function (EMFRF) is defined as the frequency domain quotient of the vibration response and the squared capacitor voltage, and it is obtained from impulse current experiment. Under given excitations, the vibration response of the capacitor tank is the product of EMFRF and the square of the given capacitor voltage in frequency domain, and the radiated audible noise is calculated by structure acoustic coupling formulas. The noise level under the same excitations is also measured in laboratory, and the results are compared with the prediction. The comparison proves that the noise prediction method is effective.

  19. Study on traffic noise level of Sylhet by multiple regression analysis associated with health hazards

    Directory of Open Access Journals (Sweden)

    J. B. Alam, M. Jobair Bin Alam, M. M. Rahman, A. K. Dikshit, S. K. Khan

    Full Text Available The study reports the level of traffic-induced noise pollution in Sylhet City. For this purpose noise levels have been measured at thirty-seven major locations of the city from 7 am to 11 pm during the working days. It was observed that at all the locations the level of noise remains far above the acceptable limit for all the time. The noise level on the main road near residential area, hospital area and educational area were above the recommended level (65dBA. It was found that the predictive equations are in 60-70% correlated with the measured noise level. The study suggests that vulnerable institutions like school and hospital should be located about 60m away from the roadside unless any special arrangement to alleviate sound is used.

  20. Reduced total serum bilirubin levels are associated with ulcerative colitis.

    Directory of Open Access Journals (Sweden)

    Kathleen M Schieffer

    Full Text Available Chronic inflammation associated with inflammatory bowel disease (IBD results in increased oxidative stress that damages the colonic microenvironment. Low levels of serum bilirubin, an endogenous antioxidant, have been associated with increased risk for Crohn's disease (CD. Therefore, the aim of this study was to examine whether total serum bilirubin levels are associated with ulcerative colitis (UC. We identified a retrospective case-control population (n = 6,649 from a single tertiary care center, Penn State Hershey Medical Center (PSU and a validation cohort (n = 1,996 from Virginia Commonwealth University Medical Center (VCU. Cases were age- and sex-matched to controls (PSU: CD n = 254, UC n = 187; VCU: CD n = 233, UC n = 124. Total serum bilirubin levels were obtained from de-identified medical records and segregated into quartiles. Logistic regression analysis was performed on each quartile of total serum bilirubin compared to the last quartile (highest bilirubin levels to determine the association of total serum bilirubin with UC. Similar to CD patients, UC patients demonstrated reduced levels of total serum bilirubin compared to controls at PSU and VCU. The lowest quartile of total serum bilirubin was independently associated with UC for the PSU (OR: 1.98 [95% CI: 1.09-3.63] and VCU cohorts (OR: 6.07 [95% CI: 3.01-12.75]. Lower levels of the antioxidant bilirubin may reduce the capability of UC patients to remove reactive oxygen species leading to an increase in intestinal injury. Therapeutics that reduce oxidative stress may be beneficial for these patients.

  1. Reduction of Classroom Noise Levels Using Group Contingencies

    Science.gov (United States)

    Ring, Brandon M.; Sigurdsson, Sigurdur O.; Eubanks, Sean L.; Silverman, Kenneth

    2014-01-01

    The therapeutic workplace is an employment-based abstinence reinforcement intervention for unemployed drug users where trainees receive on-the-job employment skills training in a classroom setting. The study is an extension of prior therapeutic workplace research, which suggested that trainees frequently violated noise standards. Participants…

  2. Successful mitigation of noise level in laser workshop in RRCAT

    International Nuclear Information System (INIS)

    Kameshwar Rao, A.; Jalali, S.M.; Jain, P.C.; Farkya, S.; Mirza, Z.B.

    2009-01-01

    Overlooking a few exceptional events like earthquakes, hurricanes, storms, avalanches, waterfalls etc, the, nature is by and large silent. In the nineteenth century, with the invention of the machine, noise was born and was tolerated as necessary evil of progress. (author)

  3. Some insights into the relationship between urban air pollution and noise levels.

    Science.gov (United States)

    Kim, Ki-Hyun; Ho, Duy Xuan; Brown, Richard J C; Oh, J-M; Park, Chan Goo; Ryu, In Cheol

    2012-05-01

    The relationship between noise and air pollution was investigated in eight different districts across Seoul, Korea, between September and November 2010. The noise levels in each district were measured at both roadside and non-roadside locations. It was found that the maximum levels of noise were generally at frequencies of around 1000 Hz. The equivalent noise levels (L(eq)), over all districts, averaged 61.4 ± 7.36 dB which is slightly lower than the noise guidelines set by the World Health Organization (WHO) of 70 dB for industrial, commercial, traffic, and outdoor areas. Comparison of L(eq) levels in each district consistently indicates that noise levels are higher at roadside sites than non-roadside sites. In addition the relative dominance of noise during daytime as compared to nighttime was also apparent. Moreover, the results of an analysis relating sound levels with air pollutant levels indicate strongly that the correlation between these two parameters is the strongest at roadside sites (relative to non-roadside sites) and during nighttime (relative to daytime). The results of our data analysis point to a positive, but complex, correlation between noise levels and air pollution. Copyright © 2012 Elsevier B.V. All rights reserved.

  4. Noise suppression by noise

    OpenAIRE

    Vilar, J. M. G. (José M. G.), 1972-; Rubí Capaceti, José Miguel

    2001-01-01

    We have analyzed the interplay between an externally added noise and the intrinsic noise of systems that relax fast towards a stationary state, and found that increasing the intensity of the external noise can reduce the total noise of the system. We have established a general criterion for the appearance of this phenomenon and discussed two examples in detail.

  5. Estimating the level of dynamical noise in time series by using fractal dimensions

    International Nuclear Information System (INIS)

    Sase, Takumi; Ramírez, Jonatán Peña; Kitajo, Keiichi; Aihara, Kazuyuki; Hirata, Yoshito

    2016-01-01

    We present a method for estimating the dynamical noise level of a ‘short’ time series even if the dynamical system is unknown. The proposed method estimates the level of dynamical noise by calculating the fractal dimensions of the time series. Additionally, the method is applied to EEG data to demonstrate its possible effectiveness as an indicator of temporal changes in the level of dynamical noise. - Highlights: • A dynamical noise level estimator for time series is proposed. • The estimator does not need any information about the dynamics generating the time series. • The estimator is based on a novel definition of time series dimension (TSD). • It is demonstrated that there exists a monotonic relationship between the • TSD and the level of dynamical noise. • We apply the proposed method to human electroencephalographic data.

  6. Estimating the level of dynamical noise in time series by using fractal dimensions

    Energy Technology Data Exchange (ETDEWEB)

    Sase, Takumi, E-mail: sase@sat.t.u-tokyo.ac.jp [Graduate School of Information Science and Technology, The University of Tokyo, Tokyo 153-8505 (Japan); Ramírez, Jonatán Peña [CONACYT Research Fellow, Center for Scientific Research and Higher Education at Ensenada (CICESE), Carretera Ensenada-Tijuana No. 3918, Zona Playitas, C.P. 22860, Ensenada, Baja California (Mexico); Kitajo, Keiichi [BSI-Toyota Collaboration Center, RIKEN Brain Science Institute, Wako, Saitama 351-0198 (Japan); Aihara, Kazuyuki; Hirata, Yoshito [Graduate School of Information Science and Technology, The University of Tokyo, Tokyo 153-8505 (Japan); Institute of Industrial Science, The University of Tokyo, Tokyo 153-8505 (Japan)

    2016-03-11

    We present a method for estimating the dynamical noise level of a ‘short’ time series even if the dynamical system is unknown. The proposed method estimates the level of dynamical noise by calculating the fractal dimensions of the time series. Additionally, the method is applied to EEG data to demonstrate its possible effectiveness as an indicator of temporal changes in the level of dynamical noise. - Highlights: • A dynamical noise level estimator for time series is proposed. • The estimator does not need any information about the dynamics generating the time series. • The estimator is based on a novel definition of time series dimension (TSD). • It is demonstrated that there exists a monotonic relationship between the • TSD and the level of dynamical noise. • We apply the proposed method to human electroencephalographic data.

  7. Effects of pedagogical ideology on the perceived loudness and noise levels in preschools.

    Science.gov (United States)

    Jonsdottir, Valdis; Rantala, Leena M; Oskarsson, Gudmundur Kr; Sala, Eeva

    2015-01-01

    High activity noise levels that result in detrimental effects on speech communication have been measured in preschools. To find out if different pedagogical ideologies affect the perceived loudness and levels of noise, a questionnaire study inquiring about the experience of loudness and voice symptoms was carried out in Iceland in eight private preschools, called "Hjalli model", and in six public preschools. Noise levels were also measured in the preschools. Background variables (stress level, age, length of working career, education, smoking, and number of children per teacher) were also analyzed in order to determine how much they contributed toward voice symptoms and the experience of noisiness. Results indicate that pedagogical ideology is a significant factor for predicting noise and its consequences. Teachers in the preschool with tighter pedagogical control of discipline (the "Hjalli model") experienced lower activity noise loudness than teachers in the preschool with a more relaxed control of behavior (public preschool). Lower noise levels were also measured in the "Hjalli model" preschool and fewer "Hjalli model" teachers reported voice symptoms. Public preschool teachers experienced more stress than "Hjalli model" teachers and the stress level was, indeed, the background variable that best explained the voice symptoms and the teacher's perception of a noisy environment. Discipline, structure, and organization in the type of activity predicted the activity noise level better than the number of children in the group. Results indicate that pedagogical ideology is a significant factor for predicting self-reported noise and its consequences.

  8. A preliminary assessment of noise level during Deepawali festival in Balasore, India.

    Science.gov (United States)

    Goswami, Shreerup; Swain, Bijay Kumar; Mohapatra, Hara Prasad; Bal, Kshirod Kumar

    2013-11-01

    A preliminary assessment of noise levels during Deepawali, was made in the present study. In order to assess the situation of noise levels in and around Balasore during two consecutive Deepawali of the year 2010 and 2011; noise monitoring was carried out in three different specified times (4:30-7:00 p.m., 7:00-10:30 p.m., 10:30 p.m.-1:00 a.m.). Noise descriptors such as L10, L50, L90, Leq, noise pollution level and noise climate were assessed to reveal the extent of noise pollution in this festival of crackers. Permissible limit of noise levels (Leq) prescribed by WHO during the festival was 100 dB and Lmax must not exceed 110 dB during such occasion. However, in all the cases Lmax and NPL values exceeded 110 dB, while Leq values ranged from 92.9 to 101.9 dB during 2010 Deepawali and 81.5 to 100.8 dB during 2011 Deepawali. On the other hand, all the noise monitoring sites belonged to residential areas. The assessed noise levels during such festivity are much more than 55/45 dB i.e. prescribed for residential areas for day/night time by CPCB. However, it was observed that the noise of Deepawali (Leq) decreased considerably and was less during 2011 than 2010. These may be due to increased environmental awareness among the public. Subsequently, the people of Balasore prefered to celebrate Deepawali, the festival of lights without sound and smoke. Noise policy should also be worked out for a better understanding of such local, social and cultural festivals in which annoyance arise.

  9. Sources and levels of background noise in the NASA Ames 40- by 80-foot wind tunnel

    Science.gov (United States)

    Soderman, Paul T.

    1988-01-01

    Background noise levels are measured in the NASA Ames Research Center 40- by 80-Foot Wind Tunnel following installation of a sound-absorbent lining on the test-section walls. Results show that the fan-drive noise dominated the empty test-section background noise at airspeeds below 120 knots. Above 120 knots, the test-section broadband background noise was dominated by wind-induced dipole noise (except at lower harmonics of fan blade-passage tones) most likely generated at the microphone or microphone support strut. Third-octave band and narrow-band spectra are presented for several fan operating conditions and test-section airspeeds. The background noise levels can be reduced by making improvements to the microphone wind screen or support strut. Empirical equations are presented relating variations of fan noise with fan speed or blade-pitch angle. An empirical expression for typical fan noise spectra is also presented. Fan motor electric power consumption is related to the noise generation. Preliminary measurements of sound absorption by the test-section lining indicate that the 152 mm thick lining will adequately absorb test-section model noise at frequencies above 300 Hz.

  10. Plasma Total Homocysteine (tHcy) Levels in Healthy Nigerian ...

    African Journals Online (AJOL)

    Establishment and stratification of reference values for a laboratory area of practice enhances the test result interpretation and sensitivity. Plasma total homocysteine (tHcy) is a metabolite of methionine which is dependent on vitamin B6, B12 and folate as co-factors. Plasma level (Hyperhomocysteinemia) is influenced by ...

  11. Decreased total antioxidant levels and increased oxidative stress in ...

    African Journals Online (AJOL)

    Background: Chronic hyperglycaemia in diabetes mellitus leads to increased lipid peroxidation in the body, followed by the development of chronic complications due to oxidative stress. Objective: The aim of this study was to compare total antioxidant (TAO) levels and oxidative stress in type 2 diabetes mellitus (T2DM) ...

  12. Dose rate and total dose dependence of the 1/f noise performance of a GaAs operational amplifier during irradiation

    International Nuclear Information System (INIS)

    Hiemstra, D.M.

    1995-01-01

    A pictorial of a sectioned view of the torus of the International Thermonuclear Experimental Reactor (ITER) is shown. Maintenance and inspection of the reactor are required to be performed remotely. This is due to the high gamma radiation environment in vessel during inspection and maintenance activities. The custom GaAs operational amplifier is to be used to readout sensors on the in-vessel manipulator and inspection equipment. The gamma dose rate during maintenance and inspection is anticipated to be 3 Mrad(GaAs)/hour. Here, dose rate and total dose dependence of the 1/f noise performance of a custom GaAs MESFET operational amplifier during irradiation are presented. Dose rate dependent 1/f noise degradation during irradiation is believed to be due to electron trapping in deep levels, enhanced by backgating and shallow traps excited during irradiation. The reduction of this affect with accumulated total dose is believed to be due a reduction of deep level site concentration associated with substitutional oxygen. Post irradiation 1/f noise degradation is also presented.The generation-recombination noise observed post irradiation can be attributed to the production of shallow traps due to ionizing radiation

  13. Total oxidant status, total antioxidant capacity and ischemia modified albumin levels in children with celiac disease.

    Science.gov (United States)

    Sayar, Ersin; Özdem, Sebahat; Uzun, Gülbahar; İşlek, Ali; Yılmaz, Aygen; Artan, Reha

    2015-01-01

    In our study, we aimed to investigate ischemia modified albumin (IMA) as an oxidative stress marker, as well as other oxidant and antioxidant markers that have not been evaluated in children with celiac disease. A total of 37 pediatric patients who were diagnosed with celiac disease (CD) and 29 healthy children were enrolled in this prospective study. We evaluated the IMA, total oxidant status, total antioxidant capacity, sulfhydryl, and advanced oxidation protein products in all of the subjects. We also compared the levels at the time of the diagnosis, and following a gluten-free diet (GFD) in the children with CD. While the IMA and the other oxidant marker levels were significantly higher in the patient group compared to the control group, the antioxidant marker levels were found to be significantly lower in the patient group, compared to the control group. We also determined that the tissue transglutaminase IgA showed a highly positive correlation, and that the IMA showed a moderately positive correlation with the Marsh-Oberhuber histopathological stage. Additionally, the IMA and other oxidant marker levels were significantly lower, while the antioxidant marker levels were significantly higher after the GFD, compared to the pre-diet period. We detected that oxidative stress played a role in the pathogenesis of CD, and that this could be evaluated using oxidative stress markers, which would regress after the GFD. We also detected that IMA is a marker that shows a correlation with the histopathological stage, and may be used in the diagnosis.

  14. Assessment of noise levels generated by music shops in an urban city in Nigeria.

    Science.gov (United States)

    Ebare, M N; Omuemu, V O; Isah, E C

    2011-09-01

    To assess the level of noise generated by music shops in an urban city in Nigeria. Cross-sectional, descriptive study. The study involved music shops in three out of eight identified clusters of market areas in Benin City. A semi-structured, researcher-administered questionnaire was also used to collect data from music shop owners. Noise levels generated by speakers in the music shops were measured using a sound level meter, and blood pressure measurements were taken with a mercury sphygmomanometer. Of the 250 music shops studied, more than 90.0% generated noise levels >85 dB, and 54.8% had a continuous pattern of noise. Longer duration of working years was significantly associated with decreased hearing (P = 0.01), shouting when talking (P = 0.04) and high blood pressure (P = 0.003). The position of music dealers in relation to the speakers was significantly associated with shouting when talking (P = 0.000). A significant association was found between higher levels of noise and high blood pressure (P = 0.004). This study found very high levels of noise in music shops, which could be a source of occupational noise exposure among music dealers. Enlightenment campaigns on the hazards of exposure to loud noise and periodic audiometry examinations are recommended for this occupational group. Copyright © 2011 The Royal Society for Public Health. Published by Elsevier Ltd. All rights reserved.

  15. Environmental impact of noise levels in and around opencast bauxite mine.

    Science.gov (United States)

    Kisku, G C; Barman, S C; Kidwai, M M; Bhargava, S K

    2002-01-01

    Until recently, noise pollution has not been paid adequate attention as air, water and land pollution. In order to assess (predict) the impact of bauxite mine noise on employees health and in and around bauxite mine environment, general noise sources and equipment noise were monitored. All these noise sources were compared with prescribed standard noise levels laid down by Central Pollution Control Board (CPCB). Data has also been compared with reference site, north block hill top which is barren and virgin plateau/top covered with grass only and free from human interference. Equipment noise levels were much higher than the other zone of the mine which does not have the corresponding standards. Rock breaker recorded the highest noise level with 73.1 +/- 14.2 to 89.5 +/- 10.1 dB (A) while from ripper dozer it was least with 61.0 +/- 17.3 to 76.2 +/- 6.2 dB (A). Meteorological parameters did not have much influence upon equipment noise up to 100 feet from the source.

  16. Environmental noise levels affect the activity budget of the Florida manatee

    Science.gov (United States)

    Miksis-Olds, Jennifer L.; Donaghay, Percy L.; Miller, James H.; Tyack, Peter L.

    2005-09-01

    Manatees inhabit coastal bays, lagoons, and estuaries because they are dependent on the aquatic vegetation that grows in shallow waters. Food requirements force manatees to occupy the same areas in which human activities are the greatest. Noise produced from human activities has the potential to affect these animals by eliciting responses ranging from mild behavioral changes to extreme aversion. This study quantifies the behavioral responses of manatees to both changing levels of ambient noise and transient noise sources. Results indicate that elevated environmental noise levels do affect the overall activity budget of this species. The proportion of time manatees spend feeding, milling, and traveling in critical habitats changed as a function of noise level. More time was spent in the directed, goal-oriented behaviors of feeding and traveling, while less time was spent milling when noise levels were highest. The animals also responded to the transient noise of approaching vessels with changes in behavioral state and movements out of the geographical area. This suggests that manatees detect and respond to changes in environmental noise levels. Whether these changes legally constitute harassment and produce biologically significant effects need to be addressed with hypothesis-driven experiments and long-term monitoring. [For Animal Bioacoustics Best Student Paper Award.

  17. A comparison of high-frequency noise levels on Cascadia Initiative ocean-bottom seismometers

    Science.gov (United States)

    Hilmo, R.; Wilcock, W. S. D.; Roland, E. C.; Bodin, P.; Connolly, J.

    2017-12-01

    The Cascadia Initiative (CI) included a four-year deployment of 70 ocean bottom seismometers (OBSs) on the Cascadia subduction zone and the Juan de Fuca plate for the purposes of characterizing seismicity and imaging the Earth's interior. The Cascadia subduction zone megathrust exhibits very low rates of seismicity relative to most other subduction zones, and there is great motivation to understand deformation on the megathrust because of its potential to produce a catastrophic M9 earthquake. An understanding of earthquake detectability of the CI network, based on knowledge of noise levels, could contribute to the interpretation of earthquake catalogs derived from the experiment and aid in the design of future networks. This project is aimed at estimating these thresholds of local earthquake detectability and how they change across the array both geographically and temporally. We characterize background noise levels recorded from 0.1 to 20 Hz with an emphasis on the frequency band used to detect local seismicity ( 3-15 Hz) to understand how noise levels depend on instrument design and environmental parameters including seafloor depth, season and oceanographic conditions. Our initial analysis of 3 weeks of vertical channel data in September, January, and May 2012-2013 shows that noise increase significantly moving from the continental shelf to deeper water. Noise levels at a given depth vary with instrument type but further analysis is required to determine whether this reflects variations in instrumental noise and ground coupling noise or errors in the scaling of the instrument response. There is also a strong seasonality in recorded noise levels at some frequencies, with winter noise levels exceeding spring and fall noise levels by up to 10 decibels in both the microseism band and in the fin whale calling band (15-20 Hz). In contrast, the seasonal noise level in the local seismicity band for a given instrument type and location shows smaller noise variation

  18. STUDY ON NOISE LEVEL GENERATED BY HUMAN ACTIVITIES IN SIBIU CITY, ROMANIA

    Directory of Open Access Journals (Sweden)

    Cristina STANCA-MOISE

    2014-10-01

    Full Text Available In this paper I have proposed an analysis and monitoring of the noise sources in the open spaces of air traffic, rail and car in Sibiu. From centralizing data obtained from the analysis of the measurements performed with equipment noise levels, we concluded that the noise and vibration produced by means of Transportation (air, road, rail can affect human health if they exceed limits. Noise is present and part of our lives and always a source of pollution as any of modern man is not conscious.

  19. Sedimentary noise and sea levels linked to land-ocean water exchange and obliquity forcing.

    Science.gov (United States)

    Li, Mingsong; Hinnov, Linda A; Huang, Chunju; Ogg, James G

    2018-03-08

    In ancient hothouses lacking ice sheets, the origins of large, million-year (myr)-scale sea-level oscillations remain a mystery, challenging current models of sea-level change. To address this mystery, we develop a sedimentary noise model for sea-level changes that simultaneously estimates geologic time and sea level from astronomically forced marginal marine stratigraphy. The noise model involves two complementary approaches: dynamic noise after orbital tuning (DYNOT) and lag-1 autocorrelation coefficient (ρ 1 ). Noise modeling of Lower Triassic marine slope stratigraphy in South China reveal evidence for global sea-level variations in the Early Triassic hothouse that are anti-phased with continental water storage variations in the Germanic Basin. This supports the hypothesis that long-period (1-2 myr) astronomically forced water mass exchange between land and ocean reservoirs is a missing link for reconciling geological records and models for sea-level change during non-glacial periods.

  20. Ambient Noise Levels in Acute Neonatal Intensive Care Unit of a Tertiary Referral Hospital

    Directory of Open Access Journals (Sweden)

    Sonia R. B D'Souza

    2017-10-01

    Full Text Available Background: Advances in neonatal care have resulted in improved survival of neonates admitted to the intensive care of the Neonatal Intensive Care Unit (NICU. However, the NCU may be an inappropriate milieu, with presence of overwhelming stimuli, most potent being the continuous presence of noise in the ambience of the NICU. Aim and Objectives: To determine and describe the ambient noise levels in the acute NICU of a tertiary referral hospital. Material and Methods: The ambient noise, in this study was the background sound existing in the environment of the acute NICU of a tertiary referral hospital in South India. The ambient noise levels were analyzed by an audiologist and acoustical engineer using a standardized and calibrated Sound Level Meter (SLM i.e., the Hand Held Analyzer type 2250, Brüel and Kjær, Denmark on a weighted frequency A and reported as dB (A. Results: The ambient noise levels were timed measurements yielded by the SLM in terms of L eq, L as well as L exceeded the standard A 10 Aeqmax levels (Leq< 45 dB, L ≤ 50 dB, and Lmax ≤ 65 10 dB.The L eq ranged from 59.4 to 62.12 dB A. A Ventilators with alarms caused the maximum amount of ambient noise yielding a L Sound Pressure Level AF (SPL of 82.14 dB A. Conclusion: The study has found high levels of ambient noise in the acute NICU. Though there are several measures to reduce the ambient noise levels in the NICU, it is essential to raise awareness among health care personnel regarding the observed ambient noise levels and its effects on neonates admitted to the NICU.

  1. Modeling signal-to-noise ratio of otoacoustic emissions in workers exposed to different industrial noise levels

    Directory of Open Access Journals (Sweden)

    Parvin Nassiri

    2016-01-01

    Full Text Available Introduction: Noise is considered as the most common cause of harmful physical effects in the workplace. A sound that is generated from within the inner ear is known as an otoacoustic emission (OAE. Distortion-product otoacoustic emissions (DPOAEs assess evoked emission and hearing capacity. The aim of this study was to assess the signal-to-noise ratio in different frequencies and at different times of the shift work in workers exposed to various levels of noise. It was also aimed to provide a statistical model for signal-to-noise ratio (SNR of OAEs in different frequencies based on the two variables of sound pressure level (SPL and exposure time. Materials and Methods: This case–control study was conducted on 45 workers during autumn 2014. The workers were divided into three groups based on the level of noise exposure. The SNR was measured in frequencies of 1000, 2000, 3000, 4000, and 6000 Hz in both ears, and in three different time intervals during the shift work. According to the inclusion criterion, SNR of 6 dB or greater was included in the study. The analysis was performed using repeated measurements of analysis of variance, spearman correlation coefficient, and paired samples t-test. Results: The results showed that there was no statistically significant difference between the three exposed groups in terms of the mean values of SNR (P > 0.05. Only in signal pressure levels of 88 dBA with an interval time of 10:30–11:00 AM, there was a statistically significant difference between the right and left ears with the mean SNR values of 3000 frequency (P = 0.038. The SPL had a significant effect on the SNR in both the right and left ears (P = 0.023, P = 0.041. The effect of the duration of measurement on the SNR was statistically significant in both the right and left ears (P = 0.027, P < 0.001. Conclusion: The findings of this study demonstrated that after noise exposure during the shift, SNR of OAEs reduced from the

  2. The Relationship between Personality Type and Acceptable Noise Levels: A Pilot Study

    OpenAIRE

    Franklin, Cliff; Johnson, Laura V.; White, Letitia; Franklin, Clay; Smith-Olinde, Laura

    2013-01-01

    Objectives. This study examined the relationship between acceptable noise level (ANL) and personality. ANL is the difference between a person’s most comfortable level for speech and the loudest level of background noise they are willing to accept while listening to speech. Design. Forty young adults with normal hearing participated. ANLs were measured and two personality tests (Big Five Inventory, Myers-Briggs Type Indicator) were administered. Results. The analysis revealed a correlation bet...

  3. Maintaining reduced noise levels in a resource-constrained neonatal intensive care unit by operant conditioning.

    Science.gov (United States)

    Ramesh, A; Denzil, S B; Linda, R; Josephine, P K; Nagapoornima, M; Suman Rao, P N; Swarna Rekha, A

    2013-03-01

    To evaluate the efficacy of operant conditioning in sustaining reduced noise levels in the neonatal intensive care unit (NICU). Quasi-experimental study on quality of care. Level III NICU of a teaching hospital in south India. 26 staff employed in the NICU. (7 Doctors, 13 Nursing staff and 6 Nursing assistants). Operant conditioning of staff activity for 6 months. This method involves positive and negative reinforcement to condition the staff to modify noise generating activities. Comparing noise levels in decibel: A weighted [dB (A)] before conditioning with levels at 18 and 24 months after conditioning. Decibel: A weighted accounts for noise that is audible to human ears. Operant conditioning for 6 months sustains the reduced noise levels to within 62 dB in ventilator room 95% CI: 60.4 - 62.2 and isolation room (95% CI: 55.8 - 61.5). In the preterm room, noise can be maintained within 52 dB (95% CI: 50.8 - 52.6). This effect is statistically significant in all the rooms at 18 months (P = 0.001). At 24 months post conditioning there is a significant rebound of noise levels by 8.6, 6.7 and 9.9 dB in the ventilator, isolation and preterm room, respectively (P =0.001). Operant conditioning for 6 months was effective in sustaining reduced noise levels. At 18 months post conditioning, the noise levels were maintained within 62 dB (A), 60 dB (A) and 52 dB (A) in the ventilator, isolation and pre-term room, respectively. Conditioning needs to be repeated at 12 months in the ventilator room and at 18 months in the other rooms.

  4. Prediction and comparison of noise levels from ground and elevated flare systems

    International Nuclear Information System (INIS)

    Obasi, E.

    2009-01-01

    Flaring is a process to dispose of hydrocarbons during clean-up, emergency shut downs or dispose a small volume waste streams of mixed gasses that cannot easily or safely be separated. This presentation discussed flaring as a noise issue. It focused on flaring noise characterization; flare noise modeling; flare sound power levels; and flare sound pressure level comparison at a distance of 1.5 km. The presentation included a photograph of flaring at a gas plant in Nigeria. The presentation listed some of the potential health effects associated with long term exposure to excessive noise, such as hearing loss; headaches; stress; fatigue; sleep disturbance; and high blood pressure. Companies flare gas to dispose waste gases in a safe and reliable manner through combustion and to depressurize gas lines during maintenance and emergencies. This presentation also discussed ground and elevated flares; components of flare noise characterization; and key factors affecting flare noise. A model to predict flaring noise was also presented. It demonstrated that at the same gas mass flow rate, the noise level from elevated flare stacks are significantly higher than ground flares. tabs., figs.

  5. Prediction and comparison of noise levels from ground and elevated flare systems

    Energy Technology Data Exchange (ETDEWEB)

    Obasi, E. [Stantec Consulting Ltd., Surrey, BC (Canada)

    2009-07-01

    Flaring is a process to dispose of hydrocarbons during clean-up, emergency shut downs or dispose a small volume waste streams of mixed gasses that cannot easily or safely be separated. This presentation discussed flaring as a noise issue. It focused on flaring noise characterization; flare noise modeling; flare sound power levels; and flare sound pressure level comparison at a distance of 1.5 km. The presentation included a photograph of flaring at a gas plant in Nigeria. The presentation listed some of the potential health effects associated with long term exposure to excessive noise, such as hearing loss; headaches; stress; fatigue; sleep disturbance; and high blood pressure. Companies flare gas to dispose waste gases in a safe and reliable manner through combustion and to depressurize gas lines during maintenance and emergencies. This presentation also discussed ground and elevated flares; components of flare noise characterization; and key factors affecting flare noise. A model to predict flaring noise was also presented. It demonstrated that at the same gas mass flow rate, the noise level from elevated flare stacks are significantly higher than ground flares. tabs., figs.

  6. Experimental Results on the Level Crossing Intervals of the Phase of Sine Wave Plus Noise

    Science.gov (United States)

    Youssef, Neji; Munakata, Tsutomu; Mimaki, Tadashi

    1993-03-01

    Experimental study was made on the level crossing intervals of a phase process of a sine wave plus narrow-band Gaussian noise. Since successive level crossings of phase do not necessarily occur alternately in the upward and downward direction due to the phase jump beyond 2π, the usual definitions of the probability densities of the level crossing intervals for continuous random processes are not applicable in the case of the phase process. Therefore, the probability densities of level crossing intervals of phase process are newly defined. Measurements of these densities were performed for noise having lowpass spectra of Gaussian and 7th order Butterworth types. Results are given for various values of the signal-to-noise power ratio and of the crossing level, and compared with corresponding approximation developed under the assumption of quasi-independence. The validity of the assumption depends on the spectrum shape of the noise.

  7. Measurement of speech levels in the presence of time varying background noise

    Science.gov (United States)

    Pearsons, K. S.; Horonjeff, R.

    1982-01-01

    Short-term speech level measurements which could be used to note changes in vocal effort in a time varying noise environment were studied. Knowing the changes in speech level would in turn allow prediction of intelligibility in the presence of aircraft flyover noise. Tests indicated that it is possible to use two second samples of speech to estimate long term root mean square speech levels. Other tests were also performed in which people read out loud during aircraft flyover noise. Results of these tests indicate that people do indeed raise their voice during flyovers at a rate of about 3-1/2 dB for each 10 dB increase in background level. This finding is in agreement with other tests of speech levels in the presence of steady state background noise.

  8. Relationship between lighting and noise levels and productivity of the occupants in automotive assembly industry.

    Science.gov (United States)

    Akbari, Jafar; Dehghan, Habibollah; Azmoon, Hiva; Forouharmajd, Farhad

    2013-01-01

    Work environment affects human productivity and his performance. The aims of this study were to investigate the effects of lighting and noise levels on human productivity in the automotive assembly industry. Subjects were 181 workers from different parts of an automobile assembly industry. Illuminance (Lx) at the height of 30 inches from the surface of work station and noise (dBA) were locally measured. Also human productivity by the Goldsmith and Hersey scale (1980) was measured. Data were analyzed by using SPSS v20 Pearson correlation coefficient. The results showed that the relationship between noise level and human productivity is negative and significant (P productivity (P > 0.05). Based on the results, in assembly tasks, noise has a negative impact on human productivity, and lighting does not affect this. So, in order to increase employee productivity, noise control and reduction to less than the standard values (less than 85 dB) is necessary.

  9. Acceptable noise level with Danish, Swedish, and non-semantic speech materials

    DEFF Research Database (Denmark)

    Brännström, K Jonas; Lantz, Johannes; Nielsen, Lars Holme

    2012-01-01

    reported results from American studies. Generally, significant differences were seen between test conditions using different types of noise within ears in each population. Significant differences were seen for ANL across populations, also when the non-semantic ISTS was used as speech signal. Conclusions......Abstract Objective: Acceptable noise level (ANL) has been established as a method to quantify the acceptance of background noise while listening to speech presented at the most comfortable level. The aim of the present study was to generate Danish, Swedish, and a non-semantic version of the ANL...... test and investigate normal-hearing Danish and Swedish subjects' performance on these tests. Design: ANL was measured using Danish and Swedish running speech with two different noises: Speech-weighted amplitude-modulated noise, and multitalker speech babble. ANL was also measured using the non...

  10. An evaluation of primary school students' views about noise levels in school

    Directory of Open Access Journals (Sweden)

    Nermin Bulunuz

    2017-06-01

    Full Text Available Effective education and teaching requires keeping classroom noise levels within specific limits. The purpose of this study is to evaluate students’ views about the noise level in school, its effects, and control of it at two primary schools (one public school and one private school located in a district of Bursa - within the scope of the TÜBİTAK 1001 project numbered 114K738. The research sample consists of 432 third and fourth graders, 223 of whom are from the public school and 209 of whom are from the private school. To collect data, a 20-question survey was administered to the students, and noise measurements were carried out in the schools. According to the findings obtained from the analysis of the answers from the student questionnaire, the students think that the noise level is high especially during break times. In parallel with the student views, the average noise level at break time during recess was found to be 74.56 dBA at the private primary school and 82.18 dBA at the public primary school. These values are much higher than the limits prescribed in the Regulation on Assessment and Management of Environmental Noise in Turkey (RAMEN European Union Harmonization Laws. The research findings show that this important problem must be dealt with urgently, and substantive efforts and activities must be launched to reduce high noise levels in schools.

  11. Effects of traffic noise on tree frog stress levels, immunity, and color signaling.

    Science.gov (United States)

    Troïanowski, Mathieu; Mondy, Nathalie; Dumet, Adeline; Arcanjo, Caroline; Lengagne, Thierry

    2017-10-01

    During the last decade, many studies have focused on the detrimental effects of noise pollution on acoustic communication. Surprisingly, although it is known that noise exposure strongly influences health in humans, studies on wildlife remain scarce. In order to gain insight into the consequences of traffic noise exposure, we experimentally manipulated traffic noise exposure as well as the endocrine status of animals to investigate physiological and phenotypic consequences of noise pollution in an anuran species. We showed that noise exposure increased stress hormone level and induced an immunosuppressive effect. In addition, both traffic noise exposure and stress hormone application negatively impacted H. arborea vocal sac coloration. Moreover, our results suggest profound changes in sexual selection processes because the best quality males with initial attractive vocal sac coloration were the most impacted by noise. Hence, our study suggests that the recent increases in anthropogenic noise worldwide might affect a broader range of animal species than previously thought, because of alteration of visual signals and immunity. Generalizing these results to other taxa is crucial for the conservation of biodiversity in an increasingly noisy world. © 2017 Society for Conservation Biology.

  12. Serum total and free carnitine levels in children with asthma.

    Science.gov (United States)

    Asilsoy, Suna; Bekem, Ozlem; Karaman, Ozkan; Uzuner, Nevin; Kavukçu, Salih

    2009-02-01

    Serum carnitine is decreased in recurrent pulmonary infections. We aimed to evaluate serum carnitine levels in asthmatic children. Study group consisted of children with stable asthma and those with acute asthma attacks, while control group included healthy children. Attack severity was determined by the pulmonary score system. Total and free carnitine levels were studied in one blood sample from the control group and stable asthmatics and in two samples from children with acute asthma exacerbation during and after the attack. All the 40 patients in the study group had moderate asthma including 30 with acute attack (13 mild and 17 moderate) and 10 with stable asthma. Carnitine levels were significantly lower in acute attack asthmatics than in the stable asthmatics and controls, while there was no significant difference between the latter two groups. Carnitine levels were not different between asthmatics with mild and moderate attack, and were similar during and after an acute attack. Serum carnitine levels decrease in children with moderate asthma during exacerbation of asthma and shortly thereafter. Further studies are needed to evaluate the effect of carnitine treatment on serum carnitine level.

  13. Total and free thyroid hormone levels in chronic renal failure.

    Directory of Open Access Journals (Sweden)

    Mehta H

    1991-04-01

    Full Text Available The levels of serum total thyroxine (TT4, triiodothyronine (TT3, free T3, (FT3 free T4 (FT4 and thyrotropin (TSH were measured in 127 clinically euthyroid patients with varying grades of chronic renal failure (CRF; and 97 healthy individuals. They were grouped as: Group I containing 93 patients on conservative management; Group II containing 34 patients on regular dialysis therapy; and Group III (normals. Group I patients showed significant decrease in TT3, TT4 and FT3 levels (p less than 0.001 as compared to Group III, whereas FT4 and TSH values in group I were not significantly altered. TT3, TT4 and FT3 levels reduced as the severity of renal damage increased. Variations in TT3, TT4, FT3, FT4 and TSH levels in Group II patients were similar to those in Group I, except for a decrease in TSH levels (p less than 0.05 as compared to normals. Several thyroid function tests are abnormal in CRF patients, however, finding of normal FT4 and TSH levels would indicate functional euthyroid status.

  14. Effect of background noise on neuronal coding of interaural level difference cues in rat inferior colliculus.

    Science.gov (United States)

    Mokri, Yasamin; Worland, Kate; Ford, Mark; Rajan, Ramesh

    2015-07-01

    Humans can accurately localize sounds even in unfavourable signal-to-noise conditions. To investigate the neural mechanisms underlying this, we studied the effect of background wide-band noise on neural sensitivity to variations in interaural level difference (ILD), the predominant cue for sound localization in azimuth for high-frequency sounds, at the characteristic frequency of cells in rat inferior colliculus (IC). Binaural noise at high levels generally resulted in suppression of responses (55.8%), but at lower levels resulted in enhancement (34.8%) as well as suppression (30.3%). When recording conditions permitted, we then examined if any binaural noise effects were related to selective noise effects at each of the two ears, which we interpreted in light of well-known differences in input type (excitation and inhibition) from each ear shaping particular forms of ILD sensitivity in the IC. At high signal-to-noise ratios (SNR), in most ILD functions (41%), the effect of background noise appeared to be due to effects on inputs from both ears, while for a large percentage (35.8%) appeared to be accounted for by effects on excitatory input. However, as SNR decreased, change in excitation became the dominant contributor to the change due to binaural background noise (63.6%). These novel findings shed light on the IC neural mechanisms for sound localization in the presence of continuous background noise. They also suggest that some effects of background noise on encoding of sound location reported to be emergent in upstream auditory areas can also be observed at the level of the midbrain. © 2015 The Authors. European Journal of Neuroscience published by Federation of European Neuroscience Societies and John Wiley & Sons Ltd.

  15. Rat hippocampal alterations could underlie behavioral abnormalities induced by exposure to moderate noise levels.

    Science.gov (United States)

    Uran, S L; Aon-Bertolino, M L; Caceres, L G; Capani, F; Guelman, L R

    2012-08-30

    Noise exposure is known to affect auditory structures in living organisms. However, it should not be ignored that many of the effects of noise are extra-auditory. Previous findings of our laboratory demonstrated that noise was able to induce behavioral alterations that are mainly related to the cerebellum (CE) and the hippocampus (HC). Therefore, the aim of this work was to reveal new data about the vulnerability of developing rat HC to moderate noise levels through the assessment of potential histological changes and hippocampal-related behavioral alterations. Male Wistar rats were exposed to noise (95-97 dB SPL, 2h daily) either for 1 day (acute noise exposure, ANE) or between postnatal days 15 and 30 (sub-acute noise exposure, SANE). Hippocampal histological evaluation as well as short (ST) and long term (LT) habituation and recognition memory assessments were performed. Results showed a mild disruption in the different hippocampal regions after ANE and SANE schemes, along with significant behavioral abnormalities. These data suggest that exposure of developing rats to noise levels of moderate intensity is able to trigger changes in the HC, an extra-auditory structure of the Central Nervous System (CNS), that could underlie the observed behavioral effects. Copyright © 2012 Elsevier B.V. All rights reserved.

  16. Advantages of binaural amplification to acceptable noise level of directional hearing aid users.

    Science.gov (United States)

    Kim, Ja-Hee; Lee, Jae Hee; Lee, Ho-Ki

    2014-06-01

    The goal of the present study was to examine whether Acceptable Noise Levels (ANLs) would be lower (greater acceptance of noise) in binaural listening than in monaural listening condition and also whether meaningfulness of background speech noise would affect ANLs for directional microphone hearing aid users. In addition, any relationships between the individual binaural benefits on ANLs and the individuals' demographic information were investigated. Fourteen hearing aid users (mean age, 64 years) participated for experimental testing. For the ANL calculation, listeners' most comfortable listening levels and background noise level were measured. Using Korean ANL material, ANLs of all participants were evaluated under monaural and binaural amplification with a counterbalanced order. The ANLs were also compared across five types of competing speech noises, consisting of 1- through 8-talker background speech maskers. Seven young normal-hearing listeners (mean age, 27 years) participated for the same measurements as a pilot testing. The results demonstrated that directional hearing aid users accepted more noise (lower ANLs) with binaural amplification than with monaural amplification, regardless of the type of competing speech. When the background speech noise became more meaningful, hearing-impaired listeners accepted less amount of noise (higher ANLs), revealing that ANL is dependent on the intelligibility of the competing speech. The individuals' binaural advantages in ANLs were significantly greater for the listeners with longer experience of hearing aids, yet not related to their age or hearing thresholds. Binaural directional microphone processing allowed hearing aid users to accept a greater amount of background noise, which may in turn improve listeners' hearing aid success. Informational masking substantially influenced background noise acceptance. Given a significant association between ANLs and duration of hearing aid usage, ANL measurement can be useful for

  17. Investigating impact of motor oil quality on vehicles engine induced noise level

    Directory of Open Access Journals (Sweden)

    I. Arefian

    2015-09-01

    Full Text Available Introduction: Vehicle engine id one of the main sources of noise which its level is influenced by various parameters. The aim of this study was to investigate the impact of motor oils quality before and after oil change on the variability of vehicle engine induced noise level. In this study it is tried to follow-up the efficacy of motor oil quality on engines sound level. Material and Method: First, engine noise of 94 vehicles were recorded for 30 seconds before and after oil change and all the vehicles technical information including mileage, type of motor oil, and type of vehicle were registered. Following, the recorded noises were calibrated in semi-anechoic chamber and the sound pressure levels were measured with A and C-weighting network and main octav bands, using a sound level meters. The obtained results analyzed using SPSS software version 17. Results: The effects of motor oil quality on different noise levels of engines were determined and a significant reduction in noise level of vehicles engine was observed. Investigation of the relationship between mileage and motor oil quality on various engines sound level manifested that vehicles with mileage ranged 100000-150000 miles had significant reduction in their sound pressure levels in comparison with other vehicles. Conclusion: The results revealed that engine oil is among factors reducing the vehicle engine induced noise level. Moreover, the engine oil type and the vehicle mileage are key variables which determine the impact of engine oil quality on reduction of the sound level of vehicles engine.

  18. Effects of pedagogical ideology on the perceived loudness and noise levels in preschools

    Science.gov (United States)

    Jonsdottir, Valdis; Rantala, Leena M.; Oskarsson, Gudmundur Kr.; Sala, Eeva

    2015-01-01

    High activity noise levels that result in detrimental effects on speech communication have been measured in preschools. To find out if different pedagogical ideologies affect the perceived loudness and levels of noise, a questionnaire study inquiring about the experience of loudness and voice symptoms was carried out in Iceland in eight private preschools, called “Hjalli model”, and in six public preschools. Noise levels were also measured in the preschools. Background variables (stress level, age, length of working career, education, smoking, and number of children per teacher) were also analyzed in order to determine how much they contributed toward voice symptoms and the experience of noisiness. Results indicate that pedagogical ideology is a significant factor for predicting noise and its consequences. Teachers in the preschool with tighter pedagogical control of discipline (the “Hjalli model”) experienced lower activity noise loudness than teachers in the preschool with a more relaxed control of behavior (public preschool). Lower noise levels were also measured in the “Hjalli model” preschool and fewer “Hjalli model” teachers reported voice symptoms. Public preschool teachers experienced more stress than “Hjalli model” teachers and the stress level was, indeed, the background variable that best explained the voice symptoms and the teacher's perception of a noisy environment. Discipline, structure, and organization in the type of activity predicted the activity noise level better than the number of children in the group. Results indicate that pedagogical ideology is a significant factor for predicting self-reported noise and its consequences. PMID:26356370

  19. Noise levels in neonatal intensive care unit and use of sound absorbing panel in the isolette.

    Science.gov (United States)

    Altuncu, E; Akman, I; Kulekci, S; Akdas, F; Bilgen, H; Ozek, E

    2009-07-01

    The purposes of this study were to measure the noise level of a busy neonatal intensive care unit (NICU) and to determine the effect of sound absorbing panel (SAP) on the level of noise inside the isolette. The sound pressure levels (SPL) of background noise, baby crying, alarms and closing of isolette's door/portholes were measured by a 2235-Brüel&Kjaer Sound Level Meter. Readings were repeated after applying SAP (3D pyramidal shaped open cell polyurethane foam) to the three lateral walls and ceiling of the isolette. The median SPL of background noise inside the NICU was 56dBA and it decreased to 47dBA inside the isolette. The median SPL of monitor alarms and baby crying inside the isolette were not different than SPL measured under radiant warmer (p>0.05). With SAP, the median SPL of temperature alarm inside the isolette decreased significantly from 82 to 72dBA, monitor alarm from 64 to 56dBA, porthole closing from 81 to 74dBA, and isolette door closing from 80 to 68dBA (pnoise produced by baby crying when SAP was used in the isolette (79dBA vs 69dBA, respectively) (pnoise. The noise level in our NICU is significantly above the universally recommended levels. Being inside the isolette protects infants from noise sources produced outside the isolette. However, very high noises are produced inside the isolette as well. Sound absorbing panel can be a simple solution and it attenuated the noise levels inside the isolette.

  20. Noiseonomics: the relationship between ambient noise levels in the sea and global economic trends.

    Science.gov (United States)

    Frisk, George V

    2012-01-01

    In recent years, the topic of noise in the sea and its effects on marine mammals has attracted considerable attention from both the scientific community and the general public. Since marine mammals rely heavily on acoustics as a primary means of communicating, navigating, and foraging in the ocean, any change in their acoustic environment may have an impact on their behavior. Specifically, a growing body of literature suggests that low-frequency, ambient noise levels in the open ocean increased approximately 3.3 dB per decade during the period 1950-2007. Here we show that this increase can be attributed primarily to commercial shipping activity, which in turn, can be linked to global economic growth. As a corollary, we conclude that ambient noise levels can be directly related to global economic conditions. We provide experimental evidence supporting this theory and discuss its implications for predicting future noise levels based on global economic trends.

  1. The impact of noise level on students' learning performance at state elementary school in Medan

    Science.gov (United States)

    Buchari, Matondang, Nazaruddin

    2017-06-01

    This study was conducted to determine the level and impact of noise on pupils' learning performance that was observed through a survey at State Elementary School (SDN 060882), which is located on the corner of Abdullah Lubis Street and Pattimura Medan Street. The study was done by measuring the noise level using the Threshold Limit Value (TLV) by taking 24 locations as the measurement points. The results indicated that the noise levels exceeded the standard TLV >55 dBA as regulated in the Decree of the Minister of Environment No. KEP/48/MENLH/11/1996. According to the data processing, the noise level at school was 70.79 dBA. The classrooms were classified into noisy zones based on the Noise Mapping. Those in Red Zone which noise level were in the range of (69-75 dBA) were Class IIIa, Class IVb, and Class VI. In addition, those in Yellow Zone which were in the range of (65-69 dBA) were Class II, Class IIIa, Class IVa and Class V. The noise brought the physiological impact in the forms of dizziness that had the highest percentage of 22% and emotional and uncomfortable feeling of 21%; the communication impact of teacher's explanation disturbance of 22%; and Pupils' learning performance was evidenced to decline of 22%. Some improvements are suggested to reduce the noise such as the reposition of windows, acoustic material to cover the classrooms' wall, and bamboo trees or grasses as the barried around the school area.

  2. SORCE Level 3 Total Solar Irradiance Daily Average V016

    Data.gov (United States)

    National Aeronautics and Space Administration — The Total Solar Irradiance (TSI) data set SOR3TSID contains the total solar irradiance (a.k.a solar constant) data collected by the Total Irradiance Monitor (TIM)...

  3. The levels of triglyceride and total cholesterol in methamphetamine dependence.

    Science.gov (United States)

    Zhang, Meijuan; Lv, Dezhao; Zhou, Wu; Ji, Lili; Zhou, Beibei; Chen, Han; Gu, Yingying; Zhao, Jiyun; He, Jincai

    2017-04-01

    The serum triglyceride (TG) and total cholesterol (TC) levels have been reported altered in the traditional drug-dependence (such as marijuana and heroin). However, studies assessing the relationships among serum TC, TG, and methamphetamine (MA)-dependence have not been described well. In this study, our aim is to explore the serum TG and TC levels in large sample of MA-dependent patients. A retrospective study was conducted in 938 MA-dependent patients who were recruited between February 2, 2008 and March 11, 2013, with social characteristics and drug-dependence history (duration of MA use, routes of drug administration, and daily dose were collected). Then, the serum levels of TC, TG, glucose (GLU), body mass index (BMI), and blood pressure were measured among the participants. Meanwhile, 985 age- and gender-matched healthy people in the physical examination center were selected as control group. Compared with the control group, significant decreases of TC, TG, GLU, and BMI were observed in MA-dependent patients (P < 0.05). Besides, we found that the daily dose of MA use was associated with TC (β = -0.079, P = 0.015) and the duration of MA use was independently related to BMI (β = -0.071, P = 0.031). This study demonstrated that the levels of TC, TG, GLU, and BMI factors altered in the MA-dependent patients. In addition, there is a negative association between MA dependence and TC and BMI.

  4. [Environmental noise levels in 2 intensive care units in a tertiary care centre].

    Science.gov (United States)

    Ornelas-Aguirre, José Manuel; Zárate-Coronado, Olivia; Gaxiola-González, Fabiola; Neyoy-Sombra, Venigna

    2017-04-03

    The World Health Organisation (WHO) has established a maximum noise level of 40 decibels (dB) for an intensive care unit. The aim of this study was to compare the noise levels in 2 different intensive care units at a tertiary care centre. Using a cross-sectional design study, an analysis was made of the maximum noise level was within the intensive coronary care unit and intensive care unit using a digital meter. A measurement was made in 4 different points of each room, with 5minute intervals, for a period of 60minutes 7:30, 14:30, and 20:30. The means of the observations were compared with descriptive statistics and Mann-Whitney U. An analysis with Kruskal-Wallis test was performed to the mean noise level. The noise observed in the intensive care unit had a mean of 64.77±3.33dB (P=.08), which was similar to that in the intensive coronary care unit, with a mean of 60.20±1.58dB (P=.129). Around 25% or more of the measurements exceeded the level recommended by the WHO by up to 20 points. Noise levels measured in intensive care wards exceed the maximum recommended level for a hospital. It is necessary to design and implement actions for greater participation of health personnel in the reduction of environmental noise. Copyright © 2017 Instituto Nacional de Cardiología Ignacio Chávez. Publicado por Masson Doyma México S.A. All rights reserved.

  5. Total Water Level Fun Facts: The Relative Contribution of Extreme Total Water Levels Along the US West Coast

    Science.gov (United States)

    Serafin, K.; Ruggiero, P.; Stockdon, H. F.

    2016-02-01

    In the fall of 2014, parts of the US West Coast endured some of the highest monthly mean sea level anomalies on record, likely due to the presence of "the blob" (Bond et al., 2015), an anomalously warm water mass in the NE Pacific. However, despite the significantly above average water levels, the coastline experienced only marginal coastal flooding and erosion hazards because the ensuing winter lacked significant storms, underscoring the fact that extreme total water levels (TWLs) are compound events. To better understand how several individual processes combine to cause devastating coastal hazards, we investigate the relative contribution that each component (waves, tides, and non-tidal residuals) has on extreme TWLs on sandy beaches. Water level records along the US West Coast are decomposed into mean sea level, astronomical tide, and non-tidal residuals (NTRs). The NTR is further split into an intra-annual seasonal signal, monthly mean sea level anomalies (inter-annual variability), and meteorological surge. TWL time series are then generated by combining water levels with wave runup, computed using wave data and beach morphology. We use this data-driven, structural function approach to investigate the spatial variability of the relative contribution of each component to the maximum TWL event on record. We also use a probabilistic, full simulation TWL model (Serafin and Ruggiero, 2014) to generate multiple, synthetic TWL records, to explore the relative contribution of each component to extreme TWL return levels. We assess the sensitivity to local beach morphology by computing TWLs for a range of observed beach slopes. Extreme TWLs are higher in Oregon and Washington than in California. Wave runup typically comprises > 50% of the TWL signal, while NTRs often compose < 5%, illustrating the importance wave climate has on the potential for extreme TWLs. While waves are typically larger in the North, California experiences greater contributions to extreme TWLs from

  6. Noiseonomics: The relationship between ambient noise levels in the sea and global economic trends

    OpenAIRE

    Frisk, George V.

    2012-01-01

    In recent years, the topic of noise in the sea and its effects on marine mammals has attracted considerable attention from both the scientific community and the general public. Since marine mammals rely heavily on acoustics as a primary means of communicating, navigating, and foraging in the ocean, any change in their acoustic environment may have an impact on their behavior. Specifically, a growing body of literature suggests that low-frequency, ambient noise levels in the open ocean increas...

  7. Ambient Noise Levels in Acute Neonatal Intensive Care Unit of a Tertiary Referral Hospital

    OpenAIRE

    Sonia R. B D'Souza; Leslie Edward Lewis; Vijay Kumar; Ramesh Bhat Y; Jayashree Purkayastha; Hari Prakash

    2017-01-01

    Background: Advances in neonatal care have resulted in improved survival of neonates admitted to the intensive care of the Neonatal Intensive Care Unit (NICU). However, the NCU may be an inappropriate milieu, with presence of overwhelming stimuli, most potent being the continuous presence of noise in the ambience of the NICU. Aim and Objectives: To determine and describe the ambient noise levels in the acute NICU of a tertiary referral hospital. Material and Methods...

  8. Determination of total mercury in nuts at ultratrace level

    International Nuclear Information System (INIS)

    Silva, Maria José da; Paim, Ana Paula S.; Pimentel, Maria Fernanda; Cervera, M. Luisa; Guardia, Miguel de la

    2014-01-01

    Highlights: • Direct analysis of Hg in nuts has been improved by a previous fat removal. • Comparison of cold vapour atomic fluorescence and direct analysis of Hg in nuts. • Mercury content in tree nuts was determined. - Abstract: Total mercury, at μg kg −1 level, was determined in different types of nuts (cashew nut, Brazil nuts, almond, pistachio, peanut, walnut) using a direct mercury analyser after previous sample defatting and by cold vapour atomic fluorescence spectrometry. There is not enough sensitivity in the second approach to determine Hg in previously digested samples due to the strong matrix effect. Mercury levels in 25 edible nut samples from Brazil and Spain were found in the range from 0.6 to 2.7 μg kg −1 by using the pyrolysis of sample after the extraction of the nut fat. The accuracy of the proposed method was confirmed by analysing certified reference materials of Coal Fly Ash-NIST SRM 1633b, Fucus-IAEA 140 and three unpolished Rice Flour NIES-10. The observed results were in good agreement with the certified values. The recoveries of different amounts of mercury added to nut samples ranged from 94 to 101%. RSD values corresponding to three measurements varied between 2.0 and 14% and the limit of detection and quantification of the method were 0.08 and 0.3 μg kg −1 , respectively

  9. Determination of total mercury in nuts at ultratrace level

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Maria José da, E-mail: maryquimica@yahoo.com.br [Departamento de Química – Universidade Federal Rural de Pernambuco, Rue Dom Manoel de Medeiros s/n. Dois irmãos, 52171-900 Recife, PE (Brazil); Paim, Ana Paula S. [Departamento de Química Fundamental – Universidade Federal de Pernambuco, Cidade Universitária, 50740-550 Recife, PE (Brazil); Pimentel, Maria Fernanda [Departamento de Engenharia Química – Universidade Federal de Pernambuco, Recife, PE (Brazil); Cervera, M. Luisa; Guardia, Miguel de la [Department of Analytical Chemistry, Research Building, University of Valencia, 50th Dr. Moliner Street, E-46100 Burjassot, Valencia (Spain)

    2014-08-01

    Highlights: • Direct analysis of Hg in nuts has been improved by a previous fat removal. • Comparison of cold vapour atomic fluorescence and direct analysis of Hg in nuts. • Mercury content in tree nuts was determined. - Abstract: Total mercury, at μg kg{sup −1} level, was determined in different types of nuts (cashew nut, Brazil nuts, almond, pistachio, peanut, walnut) using a direct mercury analyser after previous sample defatting and by cold vapour atomic fluorescence spectrometry. There is not enough sensitivity in the second approach to determine Hg in previously digested samples due to the strong matrix effect. Mercury levels in 25 edible nut samples from Brazil and Spain were found in the range from 0.6 to 2.7 μg kg{sup −1} by using the pyrolysis of sample after the extraction of the nut fat. The accuracy of the proposed method was confirmed by analysing certified reference materials of Coal Fly Ash-NIST SRM 1633b, Fucus-IAEA 140 and three unpolished Rice Flour NIES-10. The observed results were in good agreement with the certified values. The recoveries of different amounts of mercury added to nut samples ranged from 94 to 101%. RSD values corresponding to three measurements varied between 2.0 and 14% and the limit of detection and quantification of the method were 0.08 and 0.3 μg kg{sup −1}, respectively.

  10. Pilot study of methods and equipment for in-home noise level measurements.

    Science.gov (United States)

    Neitzel, Richard L; Heikkinen, Maire S A; Williams, Christopher C; Viet, Susan Marie; Dellarco, Michael

    2015-01-15

    Knowledge of the auditory and non-auditory effects of noise has increased dramatically over the past decade, but indoor noise exposure measurement methods have not advanced appreciably, despite the introduction of applicable new technologies. This study evaluated various conventional and smart devices for exposure assessment in the National Children's Study. Three devices were tested: a sound level meter (SLM), a dosimeter, and a smart device with a noise measurement application installed. Instrument performance was evaluated in a series of semi-controlled tests in office environments over 96-hour periods, followed by measurements made continuously in two rooms (a child's bedroom and a most used room) in nine participating homes over a 7-day period with subsequent computation of a range of noise metrics. The SLMs and dosimeters yielded similar A-weighted average noise levels. Levels measured by the smart devices often differed substantially (showing both positive and negative bias, depending on the metric) from those measured via SLM and dosimeter, and demonstrated attenuation in some frequency bands in spectral analysis compared to SLM results. Virtually all measurements exceeded the Environmental Protection Agency's 45 dBA day-night limit for indoor residential exposures. The measurement protocol developed here can be employed in homes, demonstrates the possibility of measuring long-term noise exposures in homes with technologies beyond traditional SLMs, and highlights potential pitfalls associated with measurements made by smart devices.

  11. A survey of acoustic conditions and noise levels in secondary school classrooms in England.

    Science.gov (United States)

    Shield, Bridget; Conetta, Robert; Dockrell, Julie; Connolly, Daniel; Cox, Trevor; Mydlarz, Charles

    2015-01-01

    An acoustic survey of secondary schools in England has been undertaken. Room acoustic parameters and background noise levels were measured in 185 unoccupied spaces in 13 schools to provide information on the typical acoustic environment of secondary schools. The unoccupied acoustic and noise data were correlated with various physical characteristics of the spaces. Room height and the amount of glazing were related to the unoccupied reverberation time and therefore need to be controlled to reduce reverberation to suitable levels for teaching and learning. Further analysis of the unoccupied data showed that the introduction of legislation relating to school acoustics in England and Wales in 2003 approximately doubled the number of school spaces complying with current standards. Noise levels were also measured during 274 lessons to examine typical levels generated during teaching activities in secondary schools and to investigate the influence of acoustic design on working noise levels in the classroom. Comparison of unoccupied and occupied data showed that unoccupied acoustic conditions affect the noise levels occurring during lessons. They were also related to the time spent in disruption to the lessons (e.g., students talking or shouting) and so may also have an impact upon student behavior in the classroom.

  12. Determination of Noise Level and Its Sources in the Neonatal Intensive Care Unit and Neonatal Ward

    Directory of Open Access Journals (Sweden)

    Mahdi Jahangir Blourchian

    2015-12-01

    Full Text Available Background: In Neonatal intensive care units (NICU different sound intensities and frequencies are produced from different sources, which may exert undesirable physiological effects on the infants. The aim of this study was to determine the noise level and its sources in the NICU and neonatal ward of Al-Zahra Hospital of Rasht, Iran. Methods: In this descriptive cross-sectional study, the intensity of the sounds generated by the internal and external sources in the NICU and neonatal ward was measured using a sound level meter device. The sound produced by each of the sources was individually calculated. Data were analyzed performing descriptive and analytical statistics, using SPSS version 19. Results: The mean noise levels in six rooms and a hallway during morning, afternoon and night shifts with the electromechanical devices turned on were 61.67±4.5, 61.32±4.32 and 60.71±4.56 dB, respectively. Moreover, with the devices tuned off the mean noise levels during morning, afternoon and evening shifts were 64.97±2.6, 60.6±1.29 and 57.91±4.73 dB, respectively. The differences between the mean noise levels in the neonatal wards (standard noise level=45 dB during each shift with the electromechanical devices turned on and off were statistically significant (P=0.002 and P

  13. Measuring and Assessment the Noise Level in Different Regions in Baghdad City And Compare it with The Allowable Levels

    Directory of Open Access Journals (Sweden)

    Ibtihaj Abdulwahhab Abdulrazzak

    2017-05-01

    Full Text Available This study includes measurement of the noise level of four regions in the city of Baghdad (industrial region, commercial region, residential region and quiet region and compare the value of noise in each region with the World Health Organization (WHO allowable limits, and the effect of noise on human health was explained. The "sound level meter (SLM" instrument measuring the noise value in the four regions, three measurement per month through one year was recorded (one measurement every ten days from 1/1/2015 to 30/12/2015. The noise level of the industrial region (75dB compared with the World Health Organization level allowable limit (65dB, while the commercial region (76.28dB versus (55dB and the residential region (74.94dB versus (50dB and the quiet region was (62.36dB versus (40dB of the (WHO allowable limit.

  14. Adaptive nonlocal means filtering based on local noise level for CT denoising

    International Nuclear Information System (INIS)

    Li, Zhoubo; Trzasko, Joshua D.; Lake, David S.; Blezek, Daniel J.; Manduca, Armando; Yu, Lifeng; Fletcher, Joel G.; McCollough, Cynthia H.

    2014-01-01

    Purpose: To develop and evaluate an image-domain noise reduction method based on a modified nonlocal means (NLM) algorithm that is adaptive to local noise level of CT images and to implement this method in a time frame consistent with clinical workflow. Methods: A computationally efficient technique for local noise estimation directly from CT images was developed. A forward projection, based on a 2D fan-beam approximation, was used to generate the projection data, with a noise model incorporating the effects of the bowtie filter and automatic exposure control. The noise propagation from projection data to images was analytically derived. The analytical noise map was validated using repeated scans of a phantom. A 3D NLM denoising algorithm was modified to adapt its denoising strength locally based on this noise map. The performance of this adaptive NLM filter was evaluated in phantom studies in terms of in-plane and cross-plane high-contrast spatial resolution, noise power spectrum (NPS), subjective low-contrast spatial resolution using the American College of Radiology (ACR) accreditation phantom, and objective low-contrast spatial resolution using a channelized Hotelling model observer (CHO). Graphical processing units (GPU) implementation of this noise map calculation and the adaptive NLM filtering were developed to meet demands of clinical workflow. Adaptive NLM was piloted on lower dose scans in clinical practice. Results: The local noise level estimation matches the noise distribution determined from multiple repetitive scans of a phantom, demonstrated by small variations in the ratio map between the analytical noise map and the one calculated from repeated scans. The phantom studies demonstrated that the adaptive NLM filter can reduce noise substantially without degrading the high-contrast spatial resolution, as illustrated by modulation transfer function and slice sensitivity profile results. The NPS results show that adaptive NLM denoising preserves the

  15. TCTE Level 3 Total Solar Irradiance Daily Means V002

    Data.gov (United States)

    National Aeronautics and Space Administration — The Total Solar Irradiance (TSI) Calibration Transfer Experiment (TCTE) data set TCTE3TSID contains daily averaged total solar irradiance (a.k.a solar constant) data...

  16. [Preventive effects of sound insulation windows on the indoor noise levels in a street residential building in Beijing].

    Science.gov (United States)

    Guo, Bin; Huang, Jing; Guo, Xin-biao

    2015-06-18

    To evaluate the preventive effects of sound insulation windows on traffic noise. Indoor noise levels of the residential rooms (on both the North 4th ring road side and the campus side) with closed sound insulation windows were measured using the sound level meter, and comparisons with the simultaneously measured outdoor noise levels were made. In addition, differences of indoor noise levels between rooms with closed sound insulation windows and open sound insulation windows were also compared. The average outdoor noise levels of the North 4th ring road was higher than 70 dB(A), which exceeded the limitation stated in the "Environmental Quality Standard for Noise" (GB 3096-2008) in our country. However, with the sound insulation windows closed, the indoor noise levels reduced significantly to the level under 35 dB(A) (Pwindows had significant influence on the indoor noise levels (Pwindow, when the sound insulation windows were closed, the indoor noise levels reduced 18.8 dB(A) and 8.3 dB(A) in residential rooms facing North 4th ring road side and campus side, respectively. The results indicated that installation of insulation windows had significant noise reduction effects on street residential buildings especially on the rooms facing major traffic roads. Installation of the sound insulation windows has significant preventive effects on indoor noise in the street residential building.

  17. Entropy-Based Method of Choosing the Decomposition Level in Wavelet Threshold De-noising

    Directory of Open Access Journals (Sweden)

    Yan-Fang Sang

    2010-06-01

    Full Text Available In this paper, the energy distributions of various noises following normal, log-normal and Pearson-III distributions are first described quantitatively using the wavelet energy entropy (WEE, and the results are compared and discussed. Then, on the basis of these analytic results, a method for use in choosing the decomposition level (DL in wavelet threshold de-noising (WTD is put forward. Finally, the performance of the proposed method is verified by analysis of both synthetic and observed series. Analytic results indicate that the proposed method is easy to operate and suitable for various signals. Moreover, contrary to traditional white noise testing which depends on “autocorrelations”, the proposed method uses energy distributions to distinguish real signals and noise in noisy series, therefore the chosen DL is reliable, and the WTD results of time series can be improved.

  18. Does the acceptable noise level (ANL) predict hearing-aid use?

    DEFF Research Database (Denmark)

    Olsen, Steen Østergaard; Brännström, K Jonas

    2014-01-01

    OBJECTIVE: It has been suggested that individuals have an inherent acceptance of noise in the presence of speech, and that different acceptance of noise results in different hearing-aid (HA) use. The acceptable noise level (ANL) has been proposed for measurement of this property. It has been...... claimed that the ANL magnitude can predict hearing-aid use patterns. Many papers have been published reporting on different aspects of ANL, but none have challenged the predictive power of ANL. The purpose of this study was to discuss whether ANL can predict HA use and how more reliable ANL results can...... reviewed journals as well as a number of papers from trade journals, posters and oral presentations from audiology conventions. CONCLUSIONS: An inherent acceptance of noise in the presence of speech may exist, but no method for precise measurement of ANL is available. The ANL model for prediction of HA use...

  19. Combination therapy using antioxidants and low level laser therapy (LLLT) on noise induced hearing loss (NIHL)

    Science.gov (United States)

    Chang, So-Young; Lim, Sung Kyu; Lee, Min young; Chung, Phil-Sang; Jung, Jae-Yun; Rhee, Chung-Ku

    2016-02-01

    One of the most common factors that cause hearing disorders is noise trauma. Noise is an increasing hazard and it is pervasive, which makes it difficult to take precautions and prevent noise-induced hearing loss (NIHL). The prevalence of hearing loss among factory workers to be 42 %[1]. Ocupational noise induced hearing loss (ONIHL) continues to be a significant occupational hazard. ONIHL is permanent and may cause significant disability, for which there currently exists no cure, but is largely preventable. More than 30 million Americans are potentially exposed to hazardous noise levels in occupations such as transportation, construction, and coal mining, as well as recreationally. In the mainstream setting, exposure avoidance strategies aimed to reduce the incidence of ONIHL remain the focus of public health and occupational medicine approaches[2]. In military conditions this is most often caused by such things as explosions, blasts, or loud noises from vehicles ranging from 100 to 140 dB[3] and military weapons generating approximately 140-185 dB peak sound pressure levels[4].

  20. Blast noise classification with common sound level meter metrics.

    Science.gov (United States)

    Cvengros, Robert M; Valente, Dan; Nykaza, Edward T; Vipperman, Jeffrey S

    2012-08-01

    A common set of signal features measurable by a basic sound level meter are analyzed, and the quality of information carried in subsets of these features are examined for their ability to discriminate military blast and non-blast sounds. The analysis is based on over 120 000 human classified signals compiled from seven different datasets. The study implements linear and Gaussian radial basis function (RBF) support vector machines (SVM) to classify blast sounds. Using the orthogonal centroid dimension reduction technique, intuition is developed about the distribution of blast and non-blast feature vectors in high dimensional space. Recursive feature elimination (SVM-RFE) is then used to eliminate features containing redundant information and rank features according to their ability to separate blasts from non-blasts. Finally, the accuracy of the linear and RBF SVM classifiers is listed for each of the experiments in the dataset, and the weights are given for the linear SVM classifier.

  1. Levels And Spectra Of Aircraft Noise And People\\'s Reactions In ...

    African Journals Online (AJOL)

    A study of sound levels and spectral distribution as well as people\\'s reactions to aircraft noise in three Nigerian international airports have been conducted. The study comprised physical measurements and social survey. Results show that maximum octave band pressure levels (BPLs) for Margaret Ekpo, Port Harcourt and ...

  2. Assessment of ambient noise levels in the urban residential streets of Eastern Alexandria, Egypt.

    Science.gov (United States)

    Zaki, Gehan R

    2012-12-01

    Street of Alexandria have numerous unplanned, mixed, and noisy activities that may interfere with public health and comfort. The aim of this study was to assess A-weighted ambient noise levels in urban residential streets of Eastern Alexandria, Egypt, from September 2010 to January 2011, with the objective of recommending corrective actions to minimize high noise levels. A descriptive cross-sectional study was carried out, in which A-weighted ambient noise levels were measured on the basis of 24-h periods, using Ono sokki la-5120--precision integrating sound level meter, from September 2010 to January 2011. The measurements were taken on three streets, which were selected using stratified random sampling. Seven measurement sites, along the three streets under study, were selected by site visits according to predetermined criteria. A-weighted ambient noise levels (LAeq) were the highest [70.7 (24.2) dB] on high-traffic-density and high-human-activity streets followed by streets with moderate and low traffic density and human activity [67.5 (31.3) and 62.8 (38.2) dB], respectively. It varied significantly depending on means of transportation (road traffic, train, and/or tram) and human activities (parking lots, shops, and/or street merchants). The A-weighted ambient noise levels on urban residential streets of Eastern Alexandria, Egypt, exceeded the Egyptian National Standards during the three periods of the day (daytime, evening, and night), except in some relatively quiet locations during the night. Consequently, remedial actions to reduce noise levels were recommended.

  3. Comparison of the Effect of Noise Levels on Stress Response in Two Different Operation Groups in an Orthopedic Surgery Room

    Directory of Open Access Journals (Sweden)

    Hasibe Baytan Yildiz

    2016-09-01

    Full Text Available Aim: The aim of this randomized, single-blinded study was to evaluate the effects of noise on hemodynamic and neuroendocrine stress response by measuring the level of noise in the surgery rooms of patients undergoing knee operations under neuroaxial anesthesia. Gerec ve Yontem: We compared patient responses from two groups of patients: those undergoing knee operations in a surgery room where the noise level (measured in decibels is high, and those undergoing meniscus operations in a surgery room with lower noise levels. The STAI, the State-Trait Anxiety Inventory (STAI-1, and the anxiety test (STAI-2wereperformed at preoperative and postoperative periods. 20 ml of blood sample was taken for basal, intraoperative 30th minute, and postoperative 1st hour measurements. Systolic, diastolic, and mean arterial blood pressures were found to be higher in the high noise level group. ACTH levels were increased during the early postoperative period and became normal during the late postoperative period in the high noise level group whereas ACTH levels were significantly decreased in the low-noise level group. Basal cortisol levels were significantly higher in the high noise level group. HCRP, an inflammatory response mediator was found to be decreased in both groups. Early and late blood glucose levels were significantly higher in the high noise group. There was a greater increase in early and late blood glucose levels in the high noise group. In the postoperative period, although the state-trait anxiety inventory (STAI-2 levels being higher in patients subject to noisier environment determines how people feel independent of the conditions and state they are in, this result made us consider that the noise the patients were subjected to in the intraoperative period may cause a stress response. Discussion: As a result we believe that standard noise levels should be achieved by reducing the factors causing high noise levels in the operating room. This will

  4. Noise level in intensive care units of a public university hospital in Santa Marta (Colombia).

    Science.gov (United States)

    Garrido Galindo, A P; Camargo Caicedo, Y; Vélez-Pereira, A M

    2016-10-01

    To evaluate the noise level in adult, pediatric and neonatal intensive care units of a university hospital in the city of Santa Marta (Colombia). A descriptive, observational, non-interventional study with follow-up over time was carried out. Continuous sampling was conducted for 20 days for each unit using a type i sound level meter, filter frequency in A weighting and Fast mode. We recorded the maximum values, the 90th percentile as background noise, and the continuous noise level. The mean hourly levels in the adult unit varied between 57.40±1.14-63.47±2.13dBA, with a maximum between 71.55±2.32-77.22±1.94dBA, and a background noise between 53.51±1.16-60.26±2.10dBA; in the pediatric unit the mean hourly levels varied between 57.07±3.07-65.72±2.46dBA, with a maximum of 68.69±3.57-79.06±2.34dBA, and a background noise between 53.33±3.54-61.96±2.85dBA; the neonatal unit in turn presented mean hourly values between 59.54±2.41-65.33±1.77dBA, with a maximum value between 67.20±2.13-77.65±3.74dBA, and a background noise between 55.02±2.03-58.70±1.95dBA. Analysis of variance revealed a significant difference between the hourly values and between the different units, with the time of day exhibiting a greater influence. The type of unit affects the noise levels in intensive care units, the pediatric unit showing the highest values and the adult unit the lowest values. However, the parameter exerting the greatest influence upon noise level is the time of day, with higher levels in the morning and evening, and lower levels at night and in the early morning. Copyright © 2015 Elsevier España, S.L.U. y SEMICYUC. All rights reserved.

  5. Sea-Level Trend Uncertainty With Pacific Climatic Variability and Temporally-Correlated Noise

    Science.gov (United States)

    Royston, Sam; Watson, Christopher S.; Legrésy, Benoît; King, Matt A.; Church, John A.; Bos, Machiel S.

    2018-03-01

    Recent studies have identified climatic drivers of the east-west see-saw of Pacific Ocean satellite altimetry era sea level trends and a number of sea-level trend and acceleration assessments attempt to account for this. We investigate the effect of Pacific climate variability, together with temporally-correlated noise, on linear trend error estimates and determine new time-of-emergence (ToE) estimates across the Indian and Pacific Oceans. Sea-level trend studies often advocate the use of auto-regressive (AR) noise models to adequately assess formal uncertainties, yet sea level often exhibits colored but non-AR(1) noise. Standard error estimates are over- or under-estimated by an AR(1) model for much of the Indo-Pacific sea level. Allowing for PDO and ENSO variability in the trend estimate only reduces standard errors across the tropics and we find noise characteristics are largely unaffected. Of importance for trend and acceleration detection studies, formal error estimates remain on average up to 1.6 times those from an AR(1) model for long-duration tide gauge data. There is an even chance that the observed trend from the satellite altimetry era exceeds the noise in patches of the tropical Pacific and Indian Oceans and the south-west and north-east Pacific gyres. By including climate indices in the trend analysis, the time it takes for the observed linear sea-level trend to emerge from the noise reduces by up to 2 decades.

  6. The Relationship between Personality Type and Acceptable Noise Levels: A Pilot Study.

    Science.gov (United States)

    Franklin, Cliff; Johnson, Laura V; White, Letitia; Franklin, Clay; Smith-Olinde, Laura

    2013-01-01

    Objectives. This study examined the relationship between acceptable noise level (ANL) and personality. ANL is the difference between a person's most comfortable level for speech and the loudest level of background noise they are willing to accept while listening to speech. Design. Forty young adults with normal hearing participated. ANLs were measured and two personality tests (Big Five Inventory, Myers-Briggs Type Indicator) were administered. Results. The analysis revealed a correlation between ANL and the openness and conscientious personality dimensions from the Big Five Inventory; no correlation emerged between ANL and the Myers-Briggs personality types. Conclusions. Lower ANLs are correlated with full-time hearing aid use and the openness personality dimension; higher ANLs are correlated with part-time or hearing aid nonuse and the conscientious personality dimension. Current data suggest that those more open to new experiences may accept more noise and possibly be good hearing aid candidates, while those more conscientious may accept less noise and reject hearing aids, based on their unwillingness to accept background noise. Knowing something about a person's personality type may help audiologists determine if their patients will likely be good candidates for hearing aids.

  7. A direct method for calculating instrument noise levels in side-by-side seismometer evaluations

    Science.gov (United States)

    Holcomb, L. Gary

    1989-01-01

    The subject of determining the inherent system noise levels present in modem broadband closed loop seismic sensors has been an evolving topic ever since closed loop systems became available. Closed loop systems are unique in that the system noise can not be determined via a blocked mass test as in older conventional open loop seismic sensors. Instead, most investigators have resorted to performing measurements on two or more systems operating in close proximity to one another and to analyzing the outputs of these systems with respect to one another to ascertain their relative noise levels.The analysis of side-by-side relative performance is inherently dependent on the accuracy of the mathematical modeling of the test configuration. This report presents a direct approach to extracting the system noise levels of two linear systems with a common coherent input signal. The mathematical solution to the problem is incredibly simple; however the practical application of the method encounters some difficulties. Examples of expected accuracies are presented as derived by simulating real systems performance using computer generated random noise. In addition, examples of the performance of the method when applied to real experimental test data are shown.

  8. Noise level estimation in weakly nonlinear slowly time-varying systems

    International Nuclear Information System (INIS)

    Aerts, J R M; Dirckx, J J J; Lataire, J; Pintelon, R

    2008-01-01

    Recently, a method using multisine excitation was proposed for estimating the frequency response, the nonlinear distortions and the disturbing noise of weakly nonlinear time-invariant systems. This method has been demonstrated on the measurement of nonlinear distortions in the vibration of acoustically driven systems such as a latex membrane, which is a good example of a time-invariant system [1]. However, not all systems are perfectly time invariant, e.g. biomechanical systems. This time variation can be misinterpreted as an elevated noise floor, and the classical noise estimation method gives a wrong result. Two improved methods to retrieve the correct noise information from the measurements are presented. Both of them make use of multisine excitations. First, it is demonstrated that the improved methods give the same result as the classical noise estimation method when applied to a time-invariant system (high-quality microphone membrane). Next, it is demonstrated that the new methods clearly give an improved estimate of the noise level on time-varying systems. As an application example results for the vibration response of an eardrum are shown

  9. False high level in total bilirubin estimation in nonicteric serum

    African Journals Online (AJOL)

    estimation of total bilirubin by DiaSys and Randox reagents along with simultaneous re-estimation by Roche reagents in ... been used mainly due to slightly lower cost in ... MATERIALS AND METHODS ... air-conditioned laboratory overnight. ..... Elevated IgG causing spurious elevation in serum total bilirubin assay. Asia.

  10. Noise levels of a track-laying tractor during field operations in the vineyard

    Directory of Open Access Journals (Sweden)

    Pietro Catania

    2013-09-01

    Full Text Available Noise in agriculture is one of the risk factors to be taken into account in the assessment of the health and safety of workers; in particular, it is known that the tractor is a source of high noise. The Italian Low Decree 81/2008 defined the requirements for assessing and managing noise risk identifying a number of procedures to be adopted at different noise levels to limit workers exposure. This paper concerns the analysis of the noise risk arising from the use of a tracklaying tractor during field operations carried out in the vineyard. The objective of this study was to evaluate the noise level that comes close to the ear of the operator driving the tractor measuring the values of equivalent sound level (Leq(A and peak sound pressure (LCpk. We considered four options related to the same tractor coupled with the following tools to perform some farming operations: rototilling, chisel plough, flail mowers and vibro farmer. We considered three test conditions: T1 in flat (slope 0%, T2 uphill and T3 downhill (both 30% slope. The instrument used for the measurements is a precision integrating portable sound level meter, class 1, model HD2110L by Delta OHM, Italy. Each survey lasted 2 minutes, with an interval of measurement equal to 0.5 s. The tests were performed in compliance with the standards ISO 9612 and ISO 9432. The results show that the measured sound levels exceed the limits allowed by the regulations in almost all the test conditions; values exceeding the threshold limit of 80 dB(A were recorded coming up to a maximum value of 92.8 dB(A for flail mowers in test T1. When limits imposed by the regulations are exceeded, the operator is obliged to wear the appropriate Personal Protective Equipment.

  11. Do hearing threshold levels in workers of the furniture industry reflect their exposure to noise?

    Directory of Open Access Journals (Sweden)

    Małgorzata Pawlaczyk-Łuszczyńska

    2016-06-01

    Full Text Available Background: The aim of the study was to analyze the hearing status of employees of a furniture factory with respect to their exposure to noise and the presence of additional risk factors of noise-induced hearing loss (NIHL. Material and Methods: Noise measurements, questionnaire survey and assessment of hearing, using pure tone audiometry, were carried out in 50 male workers, aged 20–57 years, directly employed in the manufacture of furniture. The actual workers’ hearing threshold levels (HTLs were compared with the predictions calculated according to PN-ISO 1999:2000 based on age, gender and noise exposure. Results: Workers under study were exposed to noise at daily noise exposure levels of 82.7–94.8 dB (mean: 90.9 dB for a period of 3–14 years. In all subjects, mean HTL at 500 Hz, 1000 Hz, 2000 Hz and 4000 Hz did not exceed 25 dB. Nevertheless, high frequency notches were found in 11% of audiograms. The actual workers’ HTLs at 3000–6000 Hz were similar to those predicted using PN-ISO 1999:2000. There were statistical significant differences between HTLs in subgroups of people with higher (> 78 mm Hg and lower (≤ 78 mm Hg diastolic blood pressure, smokers and non-smokers, and those working with organic solvents. Hearing loss was more evident in subjects affected by the additional risk factors specified above. Conclusions: The results confirm the need to consider, in addition to noise, also some other NIHL risk factors, such as tobacco smoking, elevated blood pressure, and co-exposure to organic solvents when estimating the risk of NIHL and developing the hearing conservation programs for workers. Med Pr 2016;67(3:337–351

  12. [Do hearing threshold levels in workers of the furniture industry reflect their exposure to noise?].

    Science.gov (United States)

    Pawlaczyk-Łuszczyńska, Małgorzata; Dudarewicz, Adam; Czaja, Norman; Bortkiewicz, Alicja

    The aim of the study was to analyze the hearing status of employees of a furniture factory with respect to their exposure to noise and the presence of additional risk factors of noise-induced hearing loss (NIHL). Noise measurements, questionnaire survey and assessment of hearing, using pure tone audiometry, were carried out in 50 male workers, aged 20-57 years, directly employed in the manufacture of furniture. The actual workers' hearing threshold levels (HTLs) were compared with the predictions calculated according to PN-ISO 1999:2000 based on age, gender and noise exposure. Workers under study were exposed to noise at daily noise exposure levels of 82.7-94.8 dB (mean: 90.9 dB) for a period of 3-14 years. In all subjects, mean HTL at 500 Hz, 1000 Hz, 2000 Hz and 4000 Hz did not exceed 25 dB. Nevertheless, high frequency notches were found in 11% of audiograms. The actual workers' HTLs at 3000-6000 Hz were similar to those predicted using PN-ISO 1999:2000. There were statistical significant differences between HTLs in subgroups of people with higher (> 78 mm Hg) and lower (≤ 78 mm Hg) diastolic blood pressure, smokers and non-smokers, and those working with organic solvents. Hearing loss was more evident in subjects affected by the additional risk factors specified above. The results confirm the need to consider, in addition to noise, also some other NIHL risk factors, such as tobacco smoking, elevated blood pressure, and co-exposure to organic solvents when estimating the risk of NIHL and developing the hearing conservation programs for workers. Med Pr 2016;67(3):337-351. This work is available in Open Access model and licensed under a CC BY-NC 3.0 PL license.

  13. 36 CFR 3.15 - What is the maximum noise level for the operation of a vessel?

    Science.gov (United States)

    2010-07-01

    ... level for the operation of a vessel? 3.15 Section 3.15 Parks, Forests, and Public Property NATIONAL PARK... level for the operation of a vessel? (a) A person may not operate a vessel at a noise level exceeding... vessel is being operated in excess of the noise levels established in paragraph (a) of this section may...

  14. Critical assessment of day time traffic noise level at curbside open-air microenvironment of Kolkata City, India.

    Science.gov (United States)

    Kundu Chowdhury, Anirban; Debsarkar, Anupam; Chakrabarty, Shibnath

    2015-01-01

    The objective of the research work is to assess day time traffic noise level at curbside open-air microenvironment of Kolkata city, India under heterogeneous environmental conditions. Prevailing traffic noise level in terms of A-weighted equivalent noise level (Leq) at the microenvironment was in excess of 12.6 ± 2.1 dB(A) from the day time standard of 65 dB(A) for commercial area recommended by the Central Pollution Control Board (CPCB) of India. Noise Climate and Traffic Noise Index of the microenvironment were accounted for 13 ± 1.8 dB(A) and 88.8 ± 6.1 dB(A) respectively. A correlation analysis explored that prevailing traffic noise level of the microenvironment had weak negative (-0.21; p air temperature and relative humidity. A Varimax rotated principal component analysis explored that motorized traffic volume had moderate positive loading with background noise component (L90, L95, L99) and prevailing traffic noise level had very strong positive loading with peak noise component (L1, L5, L10). Background and peak noise component cumulatively explained 80.98 % of variance in the data set. Traffic noise level at curbside open-air microenvironment of Kolkata City was higher than the standard recommended by CPCB of India. It was highly annoying also. Air temperature and relative humidity had little influence and the peak noise component had the most significant influence on the prevailing traffic noise level at curbside open-air microenvironment. Therefore, traffic noise level at the microenvironment of the city can be reduced with careful honking and driving.

  15. Noise level in a neonatal intensive care unit in Santa Marta - Colombia.

    Science.gov (United States)

    Garrido Galindo, Angélica Patricia; Camargo Caicedo, Yiniva; Velez-Pereira, Andres M

    2017-09-30

    The environment of neonatal intensive care units is influenced by numerous sources of noise emission, which contribute to raise the noise levels, and may cause hearing impairment and other physiological and psychological changes on the newborn, as well as problems with care staff. To evaluate the level and sources of noise in the neonatal intensive care unit. Sampled for 20 consecutive days every 60 seconds in A-weighting curves and fast mode with a Type I sound level meter. Recorded the average, maximum and minimum, and the 10th, 50th and 90th percentiles. The values are integrated into hours and work shift, and studied by analysis of variance. The sources were characterized in thirds of octaves. The average level was 64.00 ±3.62 dB(A), with maximum of 76.04 ±5.73 dB(A), minimum of 54.84 ±2.61dB(A), and background noise of 57.95 ±2.83 dB(A). We found four sources with levels between 16.8-63.3 dB(A). Statistical analysis showed significant differences between the hours and work shift, with higher values in the early hours of the day. The values presented exceed the standards suggested by several organizations. The sources identified and measured recorded high values in low frequencies.

  16. BAYESIAN ANALYSIS OF WHITE NOISE LEVELS IN THE FIVE-YEAR WMAP DATA

    International Nuclear Information System (INIS)

    Groeneboom, N. E.; Eriksen, H. K.; Gorski, K.; Huey, G.; Jewell, J.; Wandelt, B.

    2009-01-01

    We develop a new Bayesian method for estimating white noise levels in CMB sky maps, and apply this algorithm to the five-year Wilkinson Microwave Anisotropy Probe (WMAP) data. We assume that the amplitude of the noise rms is scaled by a constant value, α, relative to a pre-specified noise level. We then derive the corresponding conditional density, P(α | s, C l , d), which is subsequently integrated into a general CMB Gibbs sampler. We first verify our code by analyzing simulated data sets, and then apply the framework to the WMAP data. For the foreground-reduced five-year WMAP sky maps and the nominal noise levels initially provided in the five-year data release, we find that the posterior means typically range between α = 1.005 ± 0.001 and α = 1.010 ± 0.001 depending on differencing assembly, indicating that the noise level of these maps are biased low by 0.5%-1.0%. The same problem is not observed for the uncorrected WMAP sky maps. After the preprint version of this letter appeared on astro-ph., the WMAP team has corrected the values presented on their web page, noting that the initially provided values were in fact estimates from the three-year data release, not from the five-year estimates. However, internally in their five-year analysis the correct noise values were used, and no cosmological results are therefore compromised by this error. Thus, our method has already been demonstrated in practice to be both useful and accurate.

  17. Relationship between Lighting and Noise Levels and Productivity of the Occupants in Automotive Assembly Industry

    Directory of Open Access Journals (Sweden)

    Jafar Akbari

    2013-01-01

    Full Text Available Work environment affects human productivity and his performance. The aims of this study were to investigate the effects of lighting and noise levels on human productivity in the automotive assembly industry. Method. Subjects were 181 workers from different parts of an automobile assembly industry. Illuminance (Lx at the height of 30 inches from the surface of work station and noise (dBA were locally measured. Also human productivity by the Goldsmith and Hersey scale (1980 was measured. Data were analyzed by using SPSS v20 Pearson correlation coefficient. Results. The results showed that the relationship between noise level and human productivity is negative and significant (, , but there was no significant relationship between lighting and human productivity (. Conclusion. Based on the results, in assembly tasks, noise has a negative impact on human productivity, and lighting does not affect this. So, in order to increase employee productivity, noise control and reduction to less than the standard values (less than 85 dB is necessary.

  18. Noise levels of toys for children between the ages of birth and 3 ...

    African Journals Online (AJOL)

    Design. A quantitative, non-experimental, descriptive research design was employed for this study. Subjects. Twenty toys, 5 from each of 4 categories, were chosen from a popular toy store in ... the noise levels of toys on the packaging and adherence to ASTM International standards for toy manufacturers are recommended.

  19. Noise levels of toys for children between the ages of birth and 3 ...

    African Journals Online (AJOL)

    Noise-induced hearing loss (NIHL) in children is a growing area of concern for ... Sound intensity or loudness, measured as sound pressure level (SPL) in a logarithmic decibel ..... Focus needs to be placed on increasing parents' awareness of ...

  20. Serum total proteins and creatinine levels in experimental gambian ...

    African Journals Online (AJOL)

    Attempt was therefore made to evaluate the effect of two strains of Trypanosoma brucei gambiense on total proteins and other serum biochemical parameters using vervet monkeys as a model. The outcome of both strains in vervet monkeys was traumatic as the monkeys died from infection 12 – 15 weeks post infection while ...

  1. Serum total protein, albumin and globulin levels in Trypanosoma ...

    African Journals Online (AJOL)

    The effect of orally administered Scoparia dulcis on Trypanosoma brucei-induced changes in serum total protein, albumin and globulin were investigated in rabbits over a period of twenty eight days. Results obtained show that infection resulted in hyperproteinaemia, hyperglobulinaemia and hypoalbuminaemia. However ...

  2. Investment strategy due to the minimization of portfolio noise level by observations of coarse-grained entropy

    Science.gov (United States)

    Urbanowicz, Krzysztof; Hołyst, Janusz A.

    2004-12-01

    Using a recently developed method of noise level estimation that makes use of properties of the coarse-grained entropy, we have analyzed the noise level for the Dow Jones index and a few stocks from the New York Stock Exchange. We have found that the noise level ranges from 40% to 80% of the signal variance. The condition of a minimal noise level has been applied to construct optimal portfolios from selected shares. We show that the implementation of a corresponding threshold investment strategy leads to positive returns for historical data.

  3. Effect of external pressure environment on the internal noise level due to a source inside a cylindrical tank

    Science.gov (United States)

    Clevenson, S. A.; Roussos, L. A.

    1984-01-01

    A small cylindrical tank was used to study the effect on the noise environment within a tank of conditions of atmospheric (sea level) pressure or vacuum environments on the exterior. Experimentally determined absorption coefficients were used to calculate transmission loss, transmissibility coefficients and the sound pressure (noise) level differences in the interior. The noise level differences were also measured directly for the two exterior environments and compared to various analytical approximations with limited agreement. Trend study curves indicated that if the tank transmission loss is above 25 dB, the difference in interior noise level between the vacuum and ambient pressure conditions are less than 2 dB.

  4. Investment strategy due to the minimization of portfolio noise level by observations of coarse-grained entropy

    OpenAIRE

    Krzysztof Urbanowicz; Janusz A. Holyst

    2004-01-01

    Using a recently developed method of noise level estimation that makes use of properties of the coarse grained-entropy we have analyzed the noise level for the Dow Jones index and a few stocks from the New York Stock Exchange. We have found that the noise level ranges from 40 to 80 percent of the signal variance. The condition of a minimal noise level has been applied to construct optimal portfolios from selected shares. We show that implementation of a corresponding threshold investment stra...

  5. EVALUATION OF THE ENVIRONMENTAL NOISE LEVELS IN ABUJA MUNICIPALITY USING MOBILE PHONES.

    Science.gov (United States)

    Ibekwe, T; Folorunso, D; Ebuta, A; Amodu, J; Nwegbu, M; Mairami, Z; Liman, I; Okebaram, C; Chimdi, C; Durogbola, B; Suleiman, H; Mamven, H; Baamlong, N; Dahilo, E; Gbujie, I; Ibekwe, P; Nwaorgu, O

    2016-12-01

    Noise remains a nuisance which impacts negatively on the physical, social and psychological wellbeing of man. It aggravates chronic illnesses like hypertension and other cardiopulmonary diseases. Unfortunately, increased activities from industrialization and technological transfers/drifts have tumultuously led to increased noise pollution in most of our fast growing cities today and hence the need for concerted efforts in monitoring and regulating our environmental noise. To assess the equivalent noise level (Leq) in Abuja municipality and promote a simple method for regular assessment of Leq within our environment. This is a cross-sectional community based study of the environmental Leq of Abuja municipality conducted between January 2014 and January 2016. The city was divided into 12 segments including residential, business and market areas via the Abuja Geographic Information System. The major markets were captured separately on a different scale. Measurements were taken with the mobile phone softwares having validated this with Extech 407730 digital sound level meter, serial no Z310135 . Leq(A) were measured at different points and hours of the day and night. The average Leq(A) were classified according to localities and compared with WHO standard safety levels. LeqD ranged 71-92dB(A); 42-79dB(A) and 69-90dB(A) in business/ parks, residential and market places respectively. The Night measurements were similar 18dB(A)-56dB(A) and the day-night Leq(A)=77.2dB(A) and 90.4dB(A) for residential and business zones. The night noise levels are satisfactory but the day and day-night levels are above the recommended tolerable values by WHO and therefore urgently call for awareness and legislative regulations.

  6. Reducing visitor noise levels at Muir Woods National Monument using experimental management.

    Science.gov (United States)

    Stack, David W; Peter, Newman; Manning, Robert E; Fristrup, Kurt M

    2011-03-01

    Noise impacts resources and visitor experience in many protected natural areas, and visitors can be the dominant source of noise. This experimental study tested the efficacy and acceptability of signs asking visitors to be quiet at Muir Woods National Monument, California. Signs declaring a "quiet zone" (at the park's Cathedral Grove) or a "quiet day" (throughout the park) were posted on a randomized schedule that included control days (no signs). Visitor surveys were conducted to measure the cognitive and behavioral responses of visitors to the signs and test the acceptability of these management practices to visitors. Visitors were highly supportive of these management practices and reported that they consciously limited the amount of noise they produced. Sound level measurements showed substantial decreases on days when signs were posted. © 2011 Acoustical Society of America

  7. In vitro comparison of noise levels produced by different CPAP generators.

    Science.gov (United States)

    Kirchner, Lieselotte; Wald, Martin; Jeitler, Valerie; Pollak, Arnold

    2012-01-01

    Minimization of noise exposure is an important aim of modern neonatal intensive care medicine. Binasal continuous positive airway pressure (CPAP) generators are among the most important sources of continuous noise in neonatal wards. The aim of this study was to find out which CPAP generator creates the least noise. In an experimental setup, two jet CPAP generators (Infant Flow® generator and MediJet®) and two conventional CPAP generators (Bubble CPAP® and Baby Flow®) were compared. Noise production was measured in decibels in an A-weighted scale [dB(A)] in a closed incubator at 2 mm lateral distance from the end of the nasal prongs. Reproduction of constant airway pressure and air leak was achieved by closure of the nasal prongs with a type of adhesive tape that is semipermeable to air. The noise levels produced by the four generators were significantly different (p CPAP® and 55 dB(A) for the Baby Flow®. Conventional CPAP generators work more quietly than the currently available jet CPAP generators. Copyright © 2011 S. Karger AG, Basel.

  8. High levels of sound pressure: acoustic reflex thresholds and auditory complaints of workers with noise exposure

    Directory of Open Access Journals (Sweden)

    Alexandre Scalli Mathias Duarte

    2015-08-01

    Full Text Available INTRODUCTION: The clinical evaluation of subjects with occupational noise exposure has been difficult due to the discrepancy between auditory complaints and auditory test results. This study aimed to evaluate the contralateral acoustic reflex thresholds of workers exposed to high levels of noise, and to compare these results to the subjects' auditory complaints.METHODS: This clinical retrospective study evaluated 364 workers between 1998 and 2005; their contralateral acoustic reflexes were compared to auditory complaints, age, and noise exposure time by chi-squared, Fisher's, and Spearman's tests.RESULTS: The workers' age ranged from 18 to 50 years (mean = 39.6, and noise exposure time from one to 38 years (mean = 17.3. We found that 15.1% (55 of the workers had bilateral hearing loss, 38.5% (140 had bilateral tinnitus, 52.8% (192 had abnormal sensitivity to loud sounds, and 47.2% (172 had speech recognition impairment. The variables hearing loss, speech recognition impairment, tinnitus, age group, and noise exposure time did not show relationship with acoustic reflex thresholds; however, all complaints demonstrated a statistically significant relationship with Metz recruitment at 3000 and 4000 Hz bilaterally.CONCLUSION: There was no significance relationship between auditory complaints and acoustic reflexes.

  9. Effects of venting on wind noise levels measured at the eardrum.

    Science.gov (United States)

    Chung, King

    2013-01-01

    Wind noise can be a nuisance to hearing aid users. With the advent of sophisticated feedback reduction algorithms, people with higher degrees of hearing loss are fit with larger vents than previously allowed, and more people with lesser degrees of hearing loss are fit with open hearing aids. The purpose of this study was to examine the effects of venting on wind noise levels in the ear canal for hearing aids with omnidirectional and directional microphones. Two behind-the-ear hearing aids were programmed when they were worn on a Knowles Electronics Manikin for Acoustic Research. The hearing aid worn on the right ear was programmed to the omnidirectional microphone mode and the one on the left to the directional microphone mode. The hearing aids were adjusted to linear amplification with flat frequency response in an anechoic chamber. Gains below 10 dB were used to avoid output limiting of wind noise levels at low input levels. Wind noise samples were recorded at the eardrum location in a wind tunnel at wind velocities ranging from a gentle to a strong breeze. The hearing aids were coupled to #13 tubings (i.e., open vent), or conventional skeleton earmolds with no vent, pressure vents, or 3mm vents. Polar and spectral characteristics of wind noise were analyzed off-line using MatLab programs. Wind noise levels in the ear canals were mostly predicted by vent-induced frequency response changes in the conventional earmold conditions for both omnidirectional and directional hearing aids. The open vent condition, however, yielded the lowest levels, which could not be entirely predicted by the frequency response changes of the hearing aids. This indicated that a wind-related vent effect permitted an additional amount of sound reduction in the ear canal, which could not be explained by known vent effects. For the microphone location, form factor, and gain settings tested, open fit hearing aids yielded lower noise levels at the eardrum location than conventional behind

  10. Listening level of music through headphones in train car noise environments.

    Science.gov (United States)

    Shimokura, Ryota; Soeta, Yoshiharu

    2012-09-01

    Although portable music devices are useful for passing time on trains, exposure to music using headphones for long periods carries the risk of damaging hearing acuity. The aim of this study is to examine the listening level of music through headphones in the noisy environment of a train car. Eight subjects adjusted the volume to an optimum level (L(music)) in a simulated noisy train car environment. In Experiment I, the effects of noise level (L(train)) and type of train noise (rolling, squealing, impact, and resonance) were examined. Spectral and temporal characteristics were found to be different according to the train noise type. In Experiment II, the effects of L(train) and type of music (five vocal and five instrumental music) were examined. Each music type had a different pitch strength and spectral centroid, and each was evaluated by φ(1) and W(φ(0)), respectively. These were classified as factors of the autocorrelation function (ACF) of the music. Results showed that L(music) increased as L(train) increased in both experiments, while the type of music greatly influenced L(music). The type of train noise, however, only slightly influenced L(music). L(music) can be estimated using L(train) and the ACF factors φ(1) and W(φ(0)).

  11. Determination of total hydrocarbons levels in some marine ...

    African Journals Online (AJOL)

    Pachyelina aurita), mussels (Mylitus edulis) and mangrove Oysters (Cassostrea gasar) from polluted and unpolluted (i.e. control) sampling stations in parts of the Niger Delta area has been assessed. Statistical results revealed that the THC levels ...

  12. A Comparative Land Use-Based Analysis of Noise Pollution Levels in Selected Urban Centers of Nigeria.

    Science.gov (United States)

    Baloye, David O; Palamuleni, Lobina G

    2015-09-29

    Growth in the commercialization, mobility and urbanization of human settlements across the globe has greatly exposed world urban population to potentially harmful noise levels. The situation is more disturbing in developing countries like Nigeria, where there are no sacrosanct noise laws and regulations. This study characterized noise pollution levels in Ibadan and Ile-Ife, two urban areas of Southwestern Nigeria that have experienced significant increases in population and land use activities. Eight hundred noise measurements, taken at 20 different positions in the morning, afternoon, and evening of carefully selected weekdays, in each urban area, were used for this study. Findings put the average noise levels in the urban centers at between 53 dB(A) and 89 dB (A), a far cry from the World Health Organization (WHO) permissible limits in all the land use types, with highest noise pollution levels recorded for transportation, commercial, residential and educational land use types. The result of the one-way ANOVA test carried out on the dependent variable noise and fixed factor land use types reveals a statistically significant mean noise levels across the study area (F(3,34) = 15.13, p = 0.000). The study underscores noise pollution monitoring and the urgent need to control urban noise pollution with appropriate and effective policies.

  13. A Survey of the Relationship Between Noised Pollution, Honey and Vitamin E and Plasma Level of Blood Sexual Hormones in Noise-Exposed Rats

    Directory of Open Access Journals (Sweden)

    Kenani

    2015-02-01

    Full Text Available Background This study was conducted to examine the efficacy of honey and vitamin E on fertilization capacity of noise-exposed rats by assessing whether the plasma sexual hormones levels i.e. follicle stimulating hormone (FSH, luteinizing hormone (LH and testosterone are altered in relation with noise stress. Objectives Therefore, this study aimed to evaluate the effects of honey and vitamin E on the levels of sex hormones and male fertilization capacity of noise-exposed rats. Materials and Methods This study targeted 24 male rats that were randomly divided into four equal groups including the control group that were not exposed to noise and experimental groups 1, 2 and 3 that were the untreated, honey treated and vitamin E treated groups, respectively; all of which were exposed to noise for 50 days. Next, in order to measure serum sexual hormones, blood samples of experimental and control groups were taken and analyzed. Also in order to investigate the fertility capacity of rats, the male rats of all groups were coupled with female rats. Results The results showed that in the male rats exposed to the noise stress, the levels of FSH and LH rose and the testosterone secretion fell sharply compared to not exposed rats. Additionally, the continuing effects of noise stress injury could reduce the weight of the fetus and the number of live fetuses and survival rate of the fetus. However, honey and vitamin E improved serum testosterone concentration, while declined plasma FSH and LH secretion in noise-exposed rats and enhanced fertility rate by increasing the rate of healthy alive fetuses. Conclusions It seems that noise pollution has harmful effects on the fertility of males. Also these findings may suggest the use of a natural curative approach rather than pharmaceutical drugs to optimize both neuroendocrine gonadal axis and testicular integrity induced by pathogenesis stress, and enhance fertility capacity in men.

  14. Hearing impairment among workers exposed to excessive levels of noise in ginning industries

    Directory of Open Access Journals (Sweden)

    Kamalesh J Dube

    2011-01-01

    Full Text Available Cotton ginning workers have a risk of hearing loss due to excessive noise levels at the workplace environment. In this study, estimates of typical sound levels prevailing at the workplace environment and its effects on hearing ability of the exposed workers were made among cotton ginning workers. Data on self-reported health status was collected by a questionnaire survey at 10 cotton ginning industries located at Jalgaon district of Maharashtra state, India. The cotton ginning workers were exposed to continuous noise levels between 89 and 106 dBA. The hearing ability of the subjects was accessed by pure tone audiometry. The results of audiometry show mild, moderate and moderately severe degree of hearing impairment among the cotton ginning workers. The data generated during the study show that hearing loss was significantly associated with period of exposure to the workplace noise (P <0.0001. The prevalence of audiometric hearing impairment defined as a threshold average greater than 25 dB hearing level was 96% for binaural low-frequency average, 97% for binaural mid frequency average and 94% for binaural high-frequency average in the cotton ginning workers. We recommend the compulsory use of personal protective equipment like ear plug by the cotton ginning workers at the workplace environment. A regular maintenance of ginning and pressing machineries will avoid the emission of excessive noise at the workplace environment of cotton gins. A regular periodic medical examination is necessary to measure the impact of workplace noise on the health of cotton ginning workers.

  15. Modeling Speech Level as a Function of Background Noise Level and Talker-to-Listener Distance for Talkers Wearing Hearing Protection Devices

    DEFF Research Database (Denmark)

    Bouserhal, Rachel E.; Bockstael, Annelies; MacDonald, Ewen

    2017-01-01

    Purpose: Studying the variations in speech levels with changing background noise level and talker-to-listener distance for talkers wearing hearing protection devices (HPDs) can aid in understanding communication in background noise. Method: Speech was recorded using an intra-aural HPD from 12...... complements the existing model presented by Pelegrín-García, Smits, Brunskog, and Jeong (2011) and expands on it by taking into account the effects of occlusion and background noise level on changes in speech sound level. Conclusions: Three models of the relationship between vocal effort, background noise...

  16. Sublethal Effects of Diesel on Total Protein Levels and Cholesterol ...

    African Journals Online (AJOL)

    Michael Horsfall

    were handpicked at the Eagle Cement area of the New Calabar River and subjected to different levels ... groups when compared to the control in both the muscle and the viscera of the periwinkle. ... In Nigeria, oil industry operations are both offshore and onshore. ... This acts as a means of assessing the hazard or potential ...

  17. Tunneling magnetoresistance sensor with pT level 1/f magnetic noise

    Science.gov (United States)

    Deak, James G.; Zhou, Zhimin; Shen, Weifeng

    2017-05-01

    Magnetoresistive devices are important components in a large number of commercial electronic products in a wide range of applications including industrial position sensors, automotive sensors, hard disk read heads, cell phone compasses, and solid state memories. These devices are commonly based on anisotropic magnetoresistance (AMR) and giant magnetoresistance (GMR), but over the past few years tunneling magnetoresistance (TMR) has been emerging in more applications. Here we focus on recent work that has enabled the development of TMR magnetic field sensors with 1/f noise of less than 100 pT/rtHz at 1 Hz. Of the commercially available sensors, the lowest noise devices have typically been AMR, but they generally have the largest die size. Based on this observation and modeling of experimental data size and geometry dependence, we find that there is an optimal design rule that produces minimum 1/f noise. This design rule requires maximizing the areal coverage of an on-chip flux concentrator, providing it with a minimum possible total gap width, and tightly packing the gaps with MTJ elements, which increases the effective volume and decreases the saturation field of the MTJ freelayers. When properly optimized using this rule, these sensors have noise below 60 pT/rtHz, and could possibly replace fluxgate magnetometers in some applications.

  18. Assessment and analysis of noise levels in and around Ib river coalfield, Orissa, India.

    Science.gov (United States)

    Mohapatra, Haraprasad; Goswami, Shreerup

    2012-05-01

    Heavy earth moving machineries, different capacities of dumpers and loaders, blasting and drilling make the mining environment noisy. A study was carried out to assess the noise level in different opencast projects in and around Belpahar and Brajarajnagar areas of Ib river coalfield. Noise assessment was carried out in various residential, commercial and industrial places. The noise levels, especially L(eq) values of different wheel loaders, dumpers, shovel and crusher units were also assessed and were more than permissible limit (90dB) in some of their operating conditions. Sound ressure level measurements while drilling into coal and overburden at Lakhanpur opencast project yielded noise levels (L(eq)) of 81.33 to 96.2 dB. Thus, these L(eq) values of drilling machines in most of the operating conditions were above permissible limit. The average noise intensities (6 a.m.-10 p.m.: 51.6-60.875dB and 10 p.m.-6 a.m.: 42.6-49.8dB) and L(eq) values (6 a.m.-10 p.m.: 50.9-67.0dB and 10 p.m.-6 a.m.: 40.8-53.3dB) during both day and night time of the residential areas around the Ib river coalfield were in close proximity or beyond the permissible limit. The L(eq) values at some of the commercial and industrial places were beyond (6 a.m.-10 p.m.: 61.6-88.3 dB and 10 p.m.-6 a.m.: 55.4-64.8dB) permissible limit. However, in most of the cases, the L(max) noise values were more (6 a.m.-10 p.m.: 68.5-91.4 dB and 10 p.m.-6 a.m.: 69.3-76.4dB) than the permissible limit. Analysis of variance was also computed for heavy earth moving machineries in different operating conditions and also for different residential, commercial and industrial places to infer the level of significance. The difference of noise intensity produced by different wheel loaders at Lakhanpur and Lilari opencast projects, drilling machines at Lakhanpur opencast project, 50 tons capacity dumpers at various conditions of Ib river coalfield within the same operating condition was significant at both 5% and 1% levels

  19. Comparison of serum leptin, glucose, total cholesterol and total protein levels in fertile and repeat breeder cows

    Directory of Open Access Journals (Sweden)

    Saime Guzel

    2014-12-01

    Full Text Available In the present study we measured serum glucose, leptin, total cholesterol and total protein concentrations in repeat breeder cows and compared them with fertile cows. For this aim, 20 repeat breeder cows and 20 fertile cows were used as material. Repeat breeder cows were found to have lower levels of leptin and glucose as compared with fertile ones. No significant differences in total cholesterol and total protein levels were observed between the two groups. No significant correlation of leptin with glucose, total cholesterol and total protein was observed in fertile and repeat breeder cows. Low concentrations of glucose and leptin can have some effects on reproductive problems as repeat breeder and help to understand potential mechanisms impairing fertility in repeat breeder cows.

  20. The effects of noise-bandwidth, noise-fringe duration, and temporal signal location on the binaural masking-level difference.

    Science.gov (United States)

    Yasin, Ifat; Henning, G Bruce

    2012-07-01

    The effects of forward and backward noise fringes on binaural signal detectability were investigated. Masked thresholds for a 12-ms, 250-Hz, sinusoidal signal masked by Gaussian noise, centered at 250 Hz, with bandwidths from 3 to 201 Hz, were obtained in N(0)S(0) and N(0)S(π) configurations. The signal was (a) temporally centered in a 12-ms noise burst (no fringe), (b) presented at the start of a 600-ms noise burst (backward fringe), or (c) temporally centered in a 600-ms noise burst (forward-plus-backward fringe). For noise bandwidths between 3 and 75 Hz, detection in N(0)S(0) improved with the addition of a backward fringe, improving further with an additional forward fringe; there was little improvement in N(0)S(π). The binaural masking-level difference (BMLD) increased from 0 to 8 dB with a forward-plus-backward fringe as noise bandwidths increased to 100 Hz, increasing slightly to 10 dB at 201 Hz. This two-stage increase was less pronounced with a backward fringe. With no fringe, the BMLD was about 10-14 dB at all bandwidths. Performance appears to result from the interaction of across-time and across-frequency listening strategies and the possible effects of gain reduction and suppression, which combine in complex ways. Current binaural models are, as yet, unable to account fully for these effects.

  1. Male Accessory Gland Infection: Relevance of Serum Total Testosterone Levels

    Directory of Open Access Journals (Sweden)

    R. A. Condorelli

    2014-01-01

    Full Text Available Aim of the present study was to evaluate the different ultrasound characterization of fertile symptomatic patients with MAGI (male accessory gland infection according to different serum concentrations of total T (TT. We analyzed the ultrasound and hormonal data of 200 patients aged between 24.0 and 67.0 years. Patients were divided into six groups according to the sextile distribution of TT. Patients with serum concentrations of TT 6.6 ng mL−1 showed a frequency of ultrasound criteria suggestive for bilateral form of prostatitis and prostate-vesiculo-epididymitis and significantly lower compared to the other examined groups. At multivariate logistic regression analysis adjusted for age and BMI, TT was an independent predictive factor of prostatovesiculitis (OR = 0.818 [95% CI: 0.675–0.992]; P<0.01 and prostate-vesiculo-epididymitis (OR = 0.714 [95% CI: 0.578–0.880]; P<0.01, which represent the main forms of complicated MAGI. The results of this study suggest that male hypogonadism could be associated with a different ultrasound characterization of these patients.

  2. Estimation of background noise level on seismic station using statistical analysis for improved analysis accuracy

    Science.gov (United States)

    Han, S. M.; Hahm, I.

    2015-12-01

    We evaluated the background noise level of seismic stations in order to collect the observation data of high quality and produce accurate seismic information. Determining of the background noise level was used PSD (Power Spectral Density) method by McNamara and Buland (2004) in this study. This method that used long-term data is influenced by not only innate electronic noise of sensor and a pulse wave resulting from stabilizing but also missing data and controlled by the specified frequency which is affected by the irregular signals without site characteristics. It is hard and inefficient to implement process that filters out the abnormal signal within the automated system. To solve these problems, we devised a method for extracting the data which normally distributed with 90 to 99% confidence intervals at each period. The availability of the method was verified using 62-seismic stations with broadband and short-period sensors operated by the KMA (Korea Meteorological Administration). Evaluation standards were NHNM (New High Noise Model) and NLNM (New Low Noise Model) published by the USGS (United States Geological Survey). It was designed based on the western United States. However, Korean Peninsula surrounded by the ocean on three sides has a complicated geological structure and a high population density. So, we re-designed an appropriate model in Korean peninsula by statistically combined result. The important feature is that secondary-microseism peak appeared at a higher frequency band. Acknowledgements: This research was carried out as a part of "Research for the Meteorological and Earthquake Observation Technology and Its Application" supported by the 2015 National Institute of Meteorological Research (NIMR) in the Korea Meteorological Administration.

  3. Prospective cohort study on noise levels in a pediatric cardiac intensive care unit.

    Science.gov (United States)

    Garcia Guerra, Gonzalo; Joffe, Ari R; Sheppard, Cathy; Pugh, Jodie; Moez, Elham Khodayari; Dinu, Irina A; Jou, Hsing; Hartling, Lisa; Vohra, Sunita

    2018-04-01

    To describe noise levels in a pediatric cardiac intensive care unit, and to determine the relationship between sound levels and patient sedation requirements. Prospective observational study at a pediatric cardiac intensive care unit (PCICU). Sound levels were measured continuously in slow A weighted decibels dB(A) with a sound level meter SoundEarPro® during a 4-week period. Sedation requirement was assessed using the number of intermittent (PRNs) doses given per hour. Analysis was conducted with autoregressive moving average models and the Granger test for causality. 39 children were included in the study. The average (SD) sound level in the open area was 59.4 (2.5) dB(A) with a statistically significant but clinically unimportant difference between day/night hours (60.1 vs. 58.6; p-value noise levels were > 90 dB. There was a significant association between average (p-value = 0.030) and peak sound levels (p-value = 0.006), and number of sedation PRNs. Sound levels were above the recommended values with no differences between day/night or open area/single room. High sound levels were significantly associated with sedation requirements. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. Background noise levels and correlation with ship traffic in the Gulf of Catania

    Science.gov (United States)

    Viola, Salvatore; Buscaino, Giuseppa; Caruso, Francesco; Chierici, Francesco; Embriaco, Davide; Favali, Paolo; Giovanetti, Gabriele; Grammauta, Roasario; Larosa, Giuseppina; Pavan, Gianni; Pellegrino, Carmelo; Pulvirenti, Sara; Riccobene, Giorgio; Sciacca, Virginia; Simeone, Francesco; Beranzoli, Laura; Marinaro, Giuditta

    2015-04-01

    In the last decades the growing interest in the evaluation of the underwater acoustic noise for studies in the fields of geology, biology and high-energy physics is driving the scientific community to collaborate towards a multidisciplinary approach to the topic. In June 2012 in the framework of the European project EMSO, a multidisciplinary underwater observatory, named NEMO-SN1, was installed 25 km off-shore the port of Catania, at a depth of 2100 m and operated until May 2013 by INFN (Istituto Nazionale di Fisica Nucleare) and INGV (Istituto Nazionale di Geofisica e Vulcanologia). NEMO-SN1 hosted aboard geophysical, oceanographic and acoustic sensors: among these a seismic hydrophone model SMID DT-405D(V). In this work, conducted within the activity of the SMO project, the results on the evaluation of the underwater acoustic pollution in the Gulf of Catania through SMID DT-405D(V) recordings are presented. The seismic hydrophone provided a data set of about 11 months of continuous (24/7) recordings. Underwater sounds have been continuously digitized at a sampling frequency of 2 kHz and the acquired data have been stored in 10min long files for off-line analysis. To describe one-year background noise levels, the mean integrated acoustic noise was measured every second (sampling frequency 2000, NFFT 2048) in the 1/3 octave bands with centre frequency 63 Hz and for each 10 minutes-long file the 5th, the 50th and the 98th percentiles were calculated. Measured noise was correlated with the shipping traffic in the area, thanks to the data provided by an AIS receiver installed at the INFN-Laboratori Nazionali del Sud. An acoustic noise increment was measured in coincidence with the passing of crafts in the area and it was possible to identify the characteristic spectrum of each ship. A simple model for the estimation of the acoustic noise induced by the ships passing through the area was developed. The model was applied by using AIS data acquired during the operation

  5. The effect of hearing aid signal-processing schemes on acceptable noise levels: perception and prediction.

    Science.gov (United States)

    Wu, Yu-Hsiang; Stangl, Elizabeth

    2013-01-01

    The acceptable noise level (ANL) test determines the maximum noise level that an individual is willing to accept while listening to speech. The first objective of the present study was to systematically investigate the effect of wide dynamic range compression processing (WDRC), and its combined effect with digital noise reduction (DNR) and directional processing (DIR), on ANL. Because ANL represents the lowest signal-to-noise ratio (SNR) that a listener is willing to accept, the second objective was to examine whether the hearing aid output SNR could predict aided ANL across different combinations of hearing aid signal-processing schemes. Twenty-five adults with sensorineural hearing loss participated in the study. ANL was measured monaurally in two unaided and seven aided conditions, in which the status of the hearing aid processing schemes (enabled or disabled) and the location of noise (front or rear) were manipulated. The hearing aid output SNR was measured for each listener in each condition using a phase-inversion technique. The aided ANL was predicted by unaided ANL and hearing aid output SNR, under the assumption that the lowest acceptable SNR at the listener's eardrum is a constant across different ANL test conditions. Study results revealed that, on average, WDRC increased (worsened) ANL by 1.5 dB, while DNR and DIR decreased (improved) ANL by 1.1 and 2.8 dB, respectively. Because the effects of WDRC and DNR on ANL were opposite in direction but similar in magnitude, the ANL of linear/DNR-off was not significantly different from that of WDRC/DNR-on. The results further indicated that the pattern of ANL change across different aided conditions was consistent with the pattern of hearing aid output SNR change created by processing schemes. Compared with linear processing, WDRC creates a noisier sound image and makes listeners less willing to accept noise. However, this negative effect on noise acceptance can be offset by DNR, regardless of microphone mode

  6. Classification of Partial Discharge Measured under Different Levels of Noise Contamination.

    Directory of Open Access Journals (Sweden)

    Wong Jee Keen Raymond

    Full Text Available Cable joint insulation breakdown may cause a huge loss to power companies. Therefore, it is vital to diagnose the insulation quality to detect early signs of insulation failure. It is well known that there is a correlation between Partial discharge (PD and the insulation quality. Although many works have been done on PD pattern recognition, it is usually performed in a noise free environment. Also, works on PD pattern recognition in actual cable joint are less likely to be found in literature. Therefore, in this work, classifications of actual cable joint defect types from partial discharge data contaminated by noise were performed. Five cross-linked polyethylene (XLPE cable joints with artificially created defects were prepared based on the defects commonly encountered on site. Three different types of input feature were extracted from the PD pattern under artificially created noisy environment. These include statistical features, fractal features and principal component analysis (PCA features. These input features were used to train the classifiers to classify each PD defect types. Classifications were performed using three different artificial intelligence classifiers, which include Artificial Neural Networks (ANN, Adaptive Neuro-Fuzzy Inference System (ANFIS and Support Vector Machine (SVM. It was found that the classification accuracy decreases with higher noise level but PCA features used in SVM and ANN showed the strongest tolerance against noise contamination.

  7. The effect of traffic noise on the hearing level of people on Karachi streets

    International Nuclear Information System (INIS)

    Jawed, I.; Musani, A.; Mahmood, R.; Khambaty, W.Y.; Asim, M.

    2010-01-01

    To study the effects of traffic noise on hearing ability of subjects prone to traffic noise exposure. Method: A hospital based prospective study was performed comprising of 200 selected subjects significantly exposed to traffic noise. These included rickshaw drivers, traffic constables and shopkeepers in central business area. All subjects were questioned according to a Performa after which ENT examination was carried out followed by Pure Tone Audiometer y. Results: Hearing impairment showed correlation with the duration of job when analyzed by linear regression analysis with correlation coefficient r=0.36 (p<0.001), Hearing impairment was 33.81+0.42 dB according to the duration of job (in years). Conclusion: Subjects are perceptually exposed to potentially damaging sound pressure level in the metropolis of Karachi. It was observed that audio logically consistent noise induced hearing loss was found to be 0.42 dB per octave from 500 Hz to 2000 Hz per year of duration of job. (author)

  8. The Cost-Effectiveness of Lowering Permissible Noise Levels Around U.S. Airports

    Directory of Open Access Journals (Sweden)

    Boshen Jiao

    2017-12-01

    Full Text Available Aircraft noise increases the risk of cardiovascular diseases and mental illness. The allowable limit for sound in the vicinity of an airport is 65 decibels (dB averaged over a 24-h ‘day and night’ period (DNL in the United States. We evaluate the trade-off between the cost and the health benefits of changing the regulatory DNL level from 65 dB to 55 dB using a Markov model. The study used LaGuardia Airport (LGA as a case study. In compliance with 55 dB allowable limit of aircraft noise, sound insulation would be required for residential homes within the 55 dB to 65 dB DNL. A Markov model was built to assess the cost-effectiveness of installing sound insulation. One-way sensitivity analyses and Monte Carlo simulation were conducted to test uncertainty of the model. The incremental cost-effectiveness ratio of installing sound insulation for residents exposed to airplane noise from LGA was $11,163/QALY gained (95% credible interval: cost-saving and life-saving to $93,054/QALY gained. Changing the regulatory standard for noise exposure around airports from 65 dB to 55 dB comes at a very good value.

  9. [Relationship between the Mandarin acceptable noise level and the personality traits in normal hearing adults].

    Science.gov (United States)

    Wu, Dan; Chen, Jian-yong; Wang, Shuo; Zhang, Man-hua; Chen, Jing; Li, Yu-ling; Zhang, Hua

    2013-03-01

    To evaluate the relationship between the Mandarin acceptable noise level (ANL) and the personality trait for normal-hearing adults. Eighty-five Mandarin speakers, aged from 21 to 27, participated in this study. ANL materials and the Eysenck Personality Questionnaire (EPQ) questionnaire were used to test the acceptable noise level and the personality trait for normal-hearing subjects. SPSS 17.0 was used to analyze the results. ANL were (7.8 ± 2.9) dB in normal hearing participants. The P and N scores in EPQ were significantly correlated with ANL (r = 0.284 and 0.318, P 0.05). Listeners with higher ANL were more likely to be eccentric, hostile, aggressive, and instabe, no ANL differences were found in listeners who were different in introvert-extravert or lying.

  10. The Usability of Noise Level from Rock Cutting for the Prediction of Physico-Mechanical Properties of Rocks

    Science.gov (United States)

    Delibalta, M. S.; Kahraman, S.; Comakli, R.

    2015-11-01

    Because the indirect tests are easier and cheaper than the direct tests, the prediction of rock properties from the indirect testing methods is important especially for the preliminary investigations. In this study, the predictability of the physico-mechanical rock properties from the noise level measured during cutting rock with diamond saw was investigated. Noise measurement test, uniaxial compressive strength (UCS) test, Brazilian tensile strength (BTS) test, point load strength (Is) test, density test, and porosity test were carried out on 54 different rock types in the laboratory. The results were statistically analyzed to derive estimation equations. Strong correlations between the noise level and the mechanical rock properties were found. The relations follow power functions. Increasing rock strength increases the noise level. Density and porosity also correlated strongly with the noise level. The relations follow linear functions. Increasing density increases the noise level while increasing porosity decreases the noise level. The developed equations are valid for the rocks with a compressive strength below 150 MPa. Concluding remark is that the physico-mechanical rock properties can reliably be estimated from the noise level measured during cutting the rock with diamond saw.

  11. Chronic exposure to low frequency noise at moderate levels causes impaired balance in mice.

    Directory of Open Access Journals (Sweden)

    Haruka Tamura

    Full Text Available We are routinely exposed to low frequency noise (LFN; below 0.5 kHz at moderate levels of 60-70 dB sound pressure level (SPL generated from various sources in occupational and daily environments. LFN has been reported to affect balance in humans. However, there is limited information about the influence of chronic exposure to LFN at moderate levels for balance. In this study, we investigated whether chronic exposure to LFN at a moderate level of 70 dB SPL affects the vestibule, which is one of the organs responsible for balance in mice. Wild-type ICR mice were exposed for 1 month to LFN (0.1 kHz and high frequency noise (HFN; 16 kHz at 70 dB SPL at a distance of approximately 10-20 cm. Behavior analyses including rotarod, beam-crossing and footprint analyses showed impairments of balance in LFN-exposed mice but not in non-exposed mice or HFN-exposed mice. Immunohistochemical analysis showed a decreased number of vestibular hair cells and increased levels of oxidative stress in LFN-exposed mice compared to those in non-exposed mice. Our results suggest that chronic exposure to LFN at moderate levels causes impaired balance involving morphological impairments of the vestibule with enhanced levels of oxidative stress. Thus, the results of this study indicate the importance of considering the risk of chronic exposure to LFN at a moderate level for imbalance.

  12. Investigation of total α and total β radioactive level of environment mediator in the Dushu lake campus of Suzhou university

    International Nuclear Information System (INIS)

    Jiang Wenhua; Wan Jun; Liu Li; He Chao; Tang Hua; Tu Yu

    2008-01-01

    Objective: To get the message of natural radioactive level in the Dushu lake cam- pus of Suzhou university. Methods: Different types of water, soil and food in this region were collected, and then the level of total α and total β radioactivity of the sample was investigated applying model BH1216 equipment which measuring was used for low background total α and β radioactivity. Results: Total α in city water, surface water and soil were 0.061 Bq/L, 0.104 Bq/L, 1708 Bq/kg respectively, total β were 0.183 Bq/L, 0.319 Bq/L, 780 Bq/kg respectively, total α in chive, potato, water bamboo, pork, fish were 1.83, 2.36, 1.84, 3.40, 3.76 Bq/kg respectively, total α of Fish bone was at infra-monitoring lower limit, total β in them were 70.81, 96.71, 60.63, 86.20, 97.51, 73.94 Bq/kg respectively. Conclusion: The results of the investigation display that the total radioactivity in drinking water and food don't exceed limits, in surface water and soil is at normal natural background. It can be concluded that this region has not been polluted by the artificial radioactivity and the environment of human habitation is healthy and safe. (authors)

  13. Modeling Speech Level as a Function of Background Noise Level and Talker-to-Listener Distance for Talkers Wearing Hearing Protection Devices

    Science.gov (United States)

    Bouserhal, Rachel E.; Bockstael, Annelies; MacDonald, Ewen; Falk, Tiago H.; Voix, Jérémie

    2017-01-01

    Purpose: Studying the variations in speech levels with changing background noise level and talker-to-listener distance for talkers wearing hearing protection devices (HPDs) can aid in understanding communication in background noise. Method: Speech was recorded using an intra-aural HPD from 12 different talkers at 5 different distances in 3…

  14. Children's speech recognition and loudness perception with the Desired Sensation Level v5 Quiet and Noise prescriptions.

    Science.gov (United States)

    Crukley, Jeffery; Scollie, Susan D

    2012-12-01

    To determine whether Desired Sensation Level (DSL) v5 Noise is a viable hearing instrument prescriptive algorithm for children, in comparison with DSL v5 Quiet. In particular, the authors compared children's performance on measures of consonant recognition in quiet, sentence recognition in noise, and loudness perception when fitted with DSL v5 Quiet and Noise. Eleven children (ages 8 to 17 years) with stable, congenital sensorineural hearing losses participated in the study. Participants were fitted bilaterally to DSL v5 prescriptions with behind-the-ear hearing instruments. The order of prescription was counterbalanced across participants. Repeated measures analysis of variance was used to compare performance between prescriptions. Use of the Noise prescription resulted in a significant decrease in consonant perception in Quiet with low-level input, but no difference with average-level input. There was no significant difference in sentence-in-noise recognition between the two prescriptions. Loudness ratings for input levels above 72 dB SPL were significantly lower with the noise prescription. Average-level consonant recognition in quiet was preserved and aversive loudness was alleviated by the Noise prescription relative to the quiet prescription, which suggests that the DSL v5 Noise prescription may be an effective approach to managing the nonquiet listening needs of children with hearing loss.

  15. Interacting two-level defects as sources of fluctuating high-frequency noise in superconducting circuits

    Energy Technology Data Exchange (ETDEWEB)

    Mueller, Clemens [ARC Centre of Excellence for Engineered Quantum Systems, The University of Queensland, Brisbane (Australia); Lisenfeld, Juergen [Physikalisches Institut, Karlsruhe Institute of Technology, Karlsruhe (Germany); Shnirman, Alexander [Institut fuer Theory der Kondensierten Materie, Karlsruhe Institute of Technology, Karlsruhe (Germany); LD Landau Institute for Theoretical Physics, Moscow (Russian Federation); Poletto, Stefano [IBM TJ Watson Research Centre, Yorktown Heights (United States)

    2016-07-01

    Since the very first experiments, superconducting circuits have suffered from strong coupling to environmental noise, destroying quantum coherence and degrading performance. In state-of-the-art experiments, it is found that the relaxation time of superconducting qubits fluctuates as a function of time. We present measurements of such fluctuations in a 3D-transmon circuit and develop a qualitative model based on interactions within a bath of background two-level systems (TLS) which emerge from defects in the device material. In our model, the time-dependent noise density acting on the qubit emerges from its near-resonant coupling to high-frequency TLS which experience energy fluctuations due to their interaction with thermally fluctuating TLS at low frequencies. We support the model by providing experimental evidence of such energy fluctuations observed in a single TLS in a phase qubit circuit.

  16. Determination of the changes of the plasma catecholamine level by radioenzymatic method following noise-exposition

    International Nuclear Information System (INIS)

    Pinter, Cs.; Vincze, I.

    1982-01-01

    A new method was applied for the determination of plasma catecholamine levels: all the catecholamines were methylated in the presence of S-adenosyl-1-methyl 3 H-methyonine and the radioactivity of the components - separated with thin-layer chromatography - was measured by liquid scintillation. It is concluded that noise exposition for one hour per day significantly increases the plasma concentration of noradrenaline and dopamine whereas the adrenaline-level shows biphasic change: after a short increase it decreases. (L.E.)

  17. Entropy as a measure of the noise extent in a two-level quantum feedback controlled system

    Institute of Scientific and Technical Information of China (English)

    Wang Tao-Bo; Fang Mao-Fa; Hu Yao-Hua

    2007-01-01

    By introducing the von Neumann entropy as a measure of the extent of noise, this paper discusses the entropy evolution in a two-level quantum feedback controlled system. The results show that the feedback control can induce the reduction of the degree of noise, and different control schemes exhibit different noise controlling ability, the extent of the reduction also related with the position of the target state on the Bloch sphere. It is shown that the evolution of entropy can provide a real time noise observation and a systematic guideline to make reasonable choice of control strategy.

  18. Estimation of directivity and sound power levels emitted by aircrafts during taxiing, for outdoor noise prediction purpose

    NARCIS (Netherlands)

    Asensio, C.; Pavón, I.; Ruiz, M.; Pagan Munoz, Raul; Recuero, M.

    2007-01-01

    Integrated noise model (INM) is the most internationally used software to calculate noise levels near airports. Take off, landing or pass by operations can be modeled by INM, but it does not consider aircrafts taxiing, which, in some cases, can be important to accurately evaluate and reduce

  19. Acceptable noise level (ANL) with Danish and non-semantic speech materials in adult hearing-aid users

    DEFF Research Database (Denmark)

    Olsen, Steen Østergaard; Lantz, Johannes; Nielsen, Lars Holme

    2012-01-01

    The acceptable noise level (ANL) test is used for quantification of the amount of background noise subjects accept when listening to speech. This study investigates Danish hearing-aid users' ANL performance using Danish and non-semantic speech signals, the repeatability of ANL, and the association...... between ANL and outcome of the international outcome inventory for hearing aids (IOI-HA)....

  20. Acceptable noise level (ANL) with Danish and non-semantic speech materials in adult hearing-aid users

    DEFF Research Database (Denmark)

    Olsen, Steen Østergaard; Lantz, Johannes; Nielsen, Lars Holme

    2012-01-01

    The acceptable noise level (ANL) test is used for quantification of the amount of background noise subjects accept when listening to speech. This study investigates Danish hearing-aid users' ANL performance using Danish and non-semantic speech signals, the repeatability of ANL, and the association...

  1. Noise reduction technology reduces radiation dose in chronic total occlusions percutaneous coronary intervention: a propensity score-matched analysis.

    Science.gov (United States)

    Maccagni, Davide; Benincasa, Susanna; Bellini, Barbara; Candilio, Luciano; Poletti, Enrico; Carlino, Mauro; Colombo, Antonio; Azzalini, Lorenzo

    2018-03-23

    Chronic total occlusions (CTO) percutaneous coronary intervention (PCI) is associated with high radiation dose. Our study aim was to evaluate the impact of the implementation of a noise reduction technology (NRT) on patient radiation dose during CTO PCI. A total of 187 CTO PCIs performed between February 2016 and May 2017 were analyzed according to the angiographic systems utilized: Standard (n = 60) versus NRT (n = 127). Propensity score matching (PSM) was performed to control for differences in baseline characteristics. Primary endpoints were Cumulative Air Kerma at Interventional Reference Point (AK at IRP), which correlates with patient's tissue reactions; and Kerma Area Product (KAP), a surrogate measure of patient's risk of stochastic radiation effects. An Efficiency Index (defined as fluoroscopy time/AK at IRP) was calculated for each procedure. Image quality was evaluated using a 5-grade Likert-like scale. After PSM, n = 55 pairs were identified. Baseline and angiographic characteristics were well matched between groups. Compared to the Standard system, NRT was associated with lower AK at IRP [2.38 (1.80-3.66) vs. 3.24 (2.04-5.09) Gy, p = 0.035], a trend towards reduction for KAP [161 (93-244) vs. 203 (136-363) Gycm 2 , p = 0.069], and a better Efficiency Index [16.75 (12.73-26.27) vs. 13.58 (9.92-17.63) min/Gy, p = 0.003]. Image quality was similar between the two groups (4.39 ± 0.53 Standard vs. 4.34 ± 0.47 NRT, p = 0.571). In conclusion, compared with a Standard system, the use of NRT in CTO PCI is associated with lower patient radiation dose and similar image quality.

  2. Exponential signaling gain at the receptor level enhances signal-to-noise ratio in bacterial chemotaxis.

    Directory of Open Access Journals (Sweden)

    Silke Neumann

    Full Text Available Cellular signaling systems show astonishing precision in their response to external stimuli despite strong fluctuations in the molecular components that determine pathway activity. To control the effects of noise on signaling most efficiently, living cells employ compensatory mechanisms that reach from simple negative feedback loops to robustly designed signaling architectures. Here, we report on a novel control mechanism that allows living cells to keep precision in their signaling characteristics - stationary pathway output, response amplitude, and relaxation time - in the presence of strong intracellular perturbations. The concept relies on the surprising fact that for systems showing perfect adaptation an exponential signal amplification at the receptor level suffices to eliminate slowly varying multiplicative noise. To show this mechanism at work in living systems, we quantified the response dynamics of the E. coli chemotaxis network after genetically perturbing the information flux between upstream and downstream signaling components. We give strong evidence that this signaling system results in dynamic invariance of the activated response regulator against multiplicative intracellular noise. We further demonstrate that for environmental conditions, for which precision in chemosensing is crucial, the invariant response behavior results in highest chemotactic efficiency. Our results resolve several puzzling features of the chemotaxis pathway that are widely conserved across prokaryotes but so far could not be attributed any functional role.

  3. Aircrafts' taxi noise. Sound power level and directivity frequency band results

    NARCIS (Netherlands)

    Asensio, C.; Pavón, I.; Ruiz, M.; Pagan Munoz, Raul; Recuero, M.

    2009-01-01

    When noise mapping airports, the main noise sources are take offs and landings. But aircrafts' taxi noise can also be important, and should be considered, for instance when there are residential buildings near the airport's terminal. Main prediction tools, like Integrated Noise Model (INM), do not

  4. Longitudinal changes in hearing threshold levels of noise-exposed construction workers

    NARCIS (Netherlands)

    Leensen, Monique C. J.; Dreschler, Wouter A.

    2015-01-01

    Longitudinal analysis of audiometric data of a large population of noise-exposed workers provides insight into the development of noise-induced hearing loss (NIHL) as a function of noise exposure and age, particularly during the first decade of noise exposure. Data of pure-tone audiometry of 17,930

  5. SMORN-1: thermoelectrically generated noise in sheathed thermocouples and in other low level instrumentation cables

    International Nuclear Information System (INIS)

    Mathieu, F.; Meier, R.; Soenen, M.; Delcon, M.; Nysten, C.

    Starting from the fact that thermoelectric emfs of thermocouples are generated in the thermal gradients and not at the hot junction, it is shown how thermoelectric heterogeneity in conjunction with natural and forced convection phenomena gives rise to unwanted noise called: ''thermoelectric noise'' in the technological sense. A distinction is made between four different types of noise--i.e. uncorrelated noise, correlated noise, spectral noise and thermoelectric noise in the physical sense--each of which has its own characteristics. The experimental results presented reveal that noise amplitudes may be quite embarrassing when dealing with problems of quantitative signal fluctuation analysis. It is however emphasized that thermoelectric noise may also convey useful information which, without noise, might be lost

  6. Changing noise levels in a high CO2/lower pH ocean

    Science.gov (United States)

    Brewer, P. G.; Hester, K. C.; Peltzer, E. T.; Kirkwood, W. J.

    2008-12-01

    We show that ocean acidification from fossil fuel CO2 invasion and from increased respiration/reduced ventilation, has significantly reduced ocean sound absorption and thus increased ocean noise levels in the kHz frequency range. Below 10 kHz, sound absorption occurs due to well known chemical relaxations in the B(OH)3/B(OH)4- and HCO3-/CO32- systems. The pH dependence of these chemical relaxations results in decreased sound absorption (α = dB/km) as the ocean becomes more acidic from increased CO2 levels. The scale of surface ocean pH change today from the +105 ppmv change in atmospheric CO2 is about - 0.12 pH, resulting in frequency dependent decreases in sound absorption that now exceed 12% over pre- industrial. Under reasonable projections of future fossil fuel CO2 emissions and other sources a pH change of 0.3 units or more can be anticipated by mid-century, resulting in a decrease in α by almost 40%. Increases in water temperature have a smaller effect but also contribute to decreased sound absorption. Combining a lowering of 0.3 pH units with an increase of 3°C, α will decrease further to almost 45%. Ambient noise levels in the ocean within the auditory range critical for environmental, military, and economic interests are set to increase significantly due to the combined effects of decreased absorption and increasing sources from mankind's activities. Incorporation of sound absorption in modeling future ocean scenarios (R. Zeebe, personal communication) and long-term monitoring possibly with the aid of modern cabled observatories can give insights in how ocean noise will continue to change and its effect on groups such as marine mammals which communicate in the affected frequency range.

  7. Assessment of traffic noise levels in urban areas using different soft computing techniques.

    Science.gov (United States)

    Tomić, J; Bogojević, N; Pljakić, M; Šumarac-Pavlović, D

    2016-10-01

    Available traffic noise prediction models are usually based on regression analysis of experimental data, and this paper presents the application of soft computing techniques in traffic noise prediction. Two mathematical models are proposed and their predictions are compared to data collected by traffic noise monitoring in urban areas, as well as to predictions of commonly used traffic noise models. The results show that application of evolutionary algorithms and neural networks may improve process of development, as well as accuracy of traffic noise prediction.

  8. Comparison of clinical parameters and environmental noise levels between regular surgery and piezosurgery for extraction of impacted third molars

    Directory of Open Access Journals (Sweden)

    Hao-Hueng Chang

    2015-10-01

    Conclusion: The piezosurgery device produced noise levels similar to or lower than those of the high-speed drilling device. However, piezosurgery provides advantages of increased patient comfort during extraction of impacted third molars.

  9. Theory of deep level trap effects on generation-recombination noise in HgCdTe photoconductors

    International Nuclear Information System (INIS)

    Iverson, A.E.; Smith, D.L.

    1985-01-01

    We present a theory of the effect of deep level centers on the generation-recombination (g-r) noise and responsivity of an intrinsic photoconductor. The deep level centers can influence the g-r noise and responsivity in three main ways: (i) they can shorten the bulk carrier lifetime by Shockley--Read--Hall recombination; (ii) for some values of the capture cross sections, deep level densities, and temperature, the deep levels can trap a significant fraction of the photogenerated minority carriers. This trapping reduces the effective minority carrier mobility and diffusivity and thus reduces the effect of carrier sweep out on both g-r noise and responsivity; (iii) the deep level centers add a new thermal noise source, which results from fluctuations between bound and free carriers. The strength of this new noise source decreases with decreasing temperature at a slower rate than band-to-band thermal g-r noise. Calculations have been performed for a X = 0.21, n-type Hg/sub 1-x/Cd/sub x/Te photoconductor using the parameters of a commonly occurring deep level center in this material. We find that for typical operating conditions photoconductive detector performance begins to degrade as the deep level density begins to exceed 10 16 cm -3

  10. Seasonal Changes in Atmospheric Noise Levels and the Annual Variation in Pigeon Homing Performance

    Science.gov (United States)

    Hagstrum, J. T.; McIsaac, H. P.; Drob, D. P.

    2015-12-01

    The remarkable navigational ability of homing pigeons (Columba livia) is influenced by a number of factors, an unknown one of which causes the "Wintereffekt"1 or annual variation in homing performance. Minima in homeward orientation and return speeds have been observed in winter, with maxima in summer, during repetitive pigeon releases from single sites near experimental lofts in Wilhelmshaven, Göttingen, and Munich, Germany, and near Pisa, Italy1-4. Overall the annual variation is more pronounced in northern Germany than Italy4, and both mature and juvenile cohorts respond to this seasonal factor. Older, more experienced pigeons are better at compensating for its effects than naïve ones, but are still affected after numerous releases. The narrow low-frequency band of atmospheric background noise (microbaroms; 0.1-0.3 Hz) also varies with an annual cycle that generally has higher amplitudes in winter than in summer depending on location5. In addition, homing pigeons, and possibly other birds, apparently use infrasonic signals of similar frequency as navigational cues6, and a seasonal variation in background noise levels could cause corresponding changes in signal-to-noise ratios and thus in homing performance. The annual variation in homing performance, however, was not observed during long-term pigeon releases at two sites in eastern North America. The annual and geographic variability in homing performance in the northern hemisphere can be explained to a first order by seasonal changes in infrasonic noise sources related to ocean storm activity, and to the direction and intensity of stratospheric winds. In addition, increased dispersion in departure bearings of individual birds for some North American releases were likely caused by additional infrasonic noise associated with severe weather events during tornado and Atlantic hurricane seasons. 1Kramer, G. & von Saint Paul, U., J. Ornithol. 97, 353-370 (1956); 2Wallraff, H. G., Z. Tierpsychol. 17, 82-113 (1960

  11. Can Serum Albumin Level and Total Lymphocyte Count be Surrogates for Malnutrition to Predict Wound Complications After Total Knee Arthroplasty?

    Science.gov (United States)

    Morey, Vivek M; Song, Young Dong; Whang, Ji Sup; Kang, Yeon Gwi; Kim, Tae Kyun

    2016-06-01

    Although the serum albumin level and total lymphocyte count (TLC) have been reported as valid and reliable markers for defining malnutrition, their cutoff levels and predictive values for wound complications in patients undergoing total knee arthroplasty (TKA) remain questionable. A total of 3169 TKAs performed between April 2003 and December 2013 were retrospectively reviewed. We determined the prevalence of malnutrition on applying different definitions, with various cutoff values of serum albumin and TLC and analyzed the variations in outcome. The differences between groups with and without malnutrition in terms of functional outcome and complications were determined using Student's t test and analysis of variance. Multivariate logistic regression analysis was conducted to identify the independent risk factors. Among all the patients (N = 3169), the serum albumin level and TLC varied widely, with means of 4.1 g/dL and 2189 cells/mm(3), respectively. The prevalence of malnutrition (21%) as per the conventional definition (serum albumin level malnutrition was defined as serum albumin malnutrition for predicting wound complications after TKA. Copyright © 2015 Elsevier Inc. All rights reserved.

  12. An examination of methods whereby noise levels in current and new mining equipment may be reduced

    CSIR Research Space (South Africa)

    Maneylaws, A

    1997-12-01

    Full Text Available An extensive literature review of international work of mining equipment noise control has been carried out. The sources of noise on percussion rock drills, continuous miners, dust scrubbers and fans, long wall machinery and trackless vehicles...

  13. Noise levels in a neonatal intensive care unit in the Cape metropole ...

    African Journals Online (AJOL)

    Introduction. Continuous noise exposure is potentially harmful to infants\\' auditory systems and wellbeing. Although the effects of noise on infants in a neonatal intensive care unit (NICU) have been well researched overseas, limited studies have been conducted in South Africa. Aim. To conduct a detailed noise assessment ...

  14. Measurement of nuclear reactor noise at low power levels; Merenje nuklearnog reaktorskog suma na malim snagama

    Energy Technology Data Exchange (ETDEWEB)

    Velickovic, Lj; Petrovic, M [Boris Kidric Institute of nuclear sciences Vinca, Belgrade (Yugoslavia)

    1968-11-15

    Spatial and time dependence relation of neutrons from fission and other reactions in the reactor core result in non Poisson fluctuations of neutron density. Analytical formula developed for auto-correlation function includes physical parameters which characterize time behaviour of neutrons in the reactor system. Since auto-correlation function can be easily measured, it is a useful tool for experimental determination of these parameters. Noise from the ionization chamber was measured and analyzed by a digital computer. measurements were analyzed completely in the time domain (auto-correlation functions). This enabled separating the noise caused by neutron detection from the noise from neutron density fluctuation in the reactor. All the results can be analyzed by spatial independent reactor theory. Physical analysis of reactor noise was limited to determination of {beta}/l ratio from auto-correlation measurements at 0.5 W power level (RB reactor in Vinca). Three different reactor core lattices were analyzed (lattice pitch 8 cm, 11.3 cm and 14 cm). It was shown that parameter {beta}/l could be determined from auto-correlation measurements of neutron density with high precision (few percents) Prostorna i vremenska povezanost neutrona koji nastaju u fisiji i drugim procesima koji se desavaju u reaktoru dovodi do ne Poisson-ovih fluktuacija neutronske gustine. Analiticka formula, razvijena za autokorelacionu funkciju ovih fluktuacija, sadrzi fizicke parametre koji karakterisu vremensko ponasanje neutrona u reaktorskom sistemu. Kako autokorelaciona funkcija moze lako da se meri, ona je korisno sredstvo za eksperimentalno odredjivanje ovih parametara. Sum iz jonizacione komore digitalno je meren i analiziran u digitalnom racunaru. Merenja su kompletno analizirana u vremenskom domenu (autokorelacione funkeije). To je olaksalo razdvajanje suma izazvanog procesom neutronske detekcije od suma koji potice od fluktuacija neutronske gustine u reaktorskom sistemu. Svi rezultati

  15. Power distribution and substrate noise coupling investigations on the behavioral level for photon counting imaging readout circuits

    International Nuclear Information System (INIS)

    Lundgren, Jan; Abdalla, Suliman; O'Nils, Mattias; Oelmann, Bengt

    2007-01-01

    In modern mixed-signal system design, there are increasing problems associated with noise coupling caused by switching digital parts to sensitive analog parts. As a consequence, there is a growing necessity to understand these problems. In order to avoid costly design iterations, noise coupling simulations should be initiated as early as possible in the design chain. The problems associated with on-chip noise coupling have been discovered in photon counting pixel detector readout systems, where the level of integration of analog and digital circuits is very high on a very small area, and it would appear that these problems will continue to increase for future system designs in this field. This paper deals with the functionality of utilizing behavioral level models for simulating noise coupling in these readout systems. The methods and models are described and simulation results are shown for a photon counting pixel detector readout system

  16. Sea Ice Deformation State From Synthetic Aperture Radar Imagery - Part II: Effects of Spatial Resolution and Noise Level

    DEFF Research Database (Denmark)

    Dierking, Wolfgang; Dall, Jørgen

    2008-01-01

    C- and L-band airborne synthetic aperture radar (SAR) imagery acquired at like- and cross-polarization over sea ice under winter conditions is examined with the objective to study the discrimination between level ice and ice deformation features. High-resolution low-noise data were analysed...... in the first paper. In this second paper, the main topics are the effects of spatial resolution and signal-to-noise ratio. Airborne, high-resolution SAR scenes are used to generate a sequence of images with increasingly coarser spatial resolution from 5 m to 25 m, keeping the number of looks constant....... The signal-to-noise ratio is varied between typical noise levels for airborne imagery and satellite data. Areal fraction of deformed ice and average deformation distance are determined for each image product. At L-band, the retrieved values of the areal fraction get larger as the image resolution is degraded...

  17. Neural indices of phonemic discrimination and sentence-level speech intelligibility in quiet and noise: A P3 study.

    Science.gov (United States)

    Koerner, Tess K; Zhang, Yang; Nelson, Peggy B; Wang, Boxiang; Zou, Hui

    2017-07-01

    This study examined how speech babble noise differentially affected the auditory P3 responses and the associated neural oscillatory activities for consonant and vowel discrimination in relation to segmental- and sentence-level speech perception in noise. The data were collected from 16 normal-hearing participants in a double-oddball paradigm that contained a consonant (/ba/ to /da/) and vowel (/ba/ to /bu/) change in quiet and noise (speech-babble background at a -3 dB signal-to-noise ratio) conditions. Time-frequency analysis was applied to obtain inter-trial phase coherence (ITPC) and event-related spectral perturbation (ERSP) measures in delta, theta, and alpha frequency bands for the P3 response. Behavioral measures included percent correct phoneme detection and reaction time as well as percent correct IEEE sentence recognition in quiet and in noise. Linear mixed-effects models were applied to determine possible brain-behavior correlates. A significant noise-induced reduction in P3 amplitude was found, accompanied by significantly longer P3 latency and decreases in ITPC across all frequency bands of interest. There was a differential effect of noise on consonant discrimination and vowel discrimination in both ERP and behavioral measures, such that noise impacted the detection of the consonant change more than the vowel change. The P3 amplitude and some of the ITPC and ERSP measures were significant predictors of speech perception at segmental- and sentence-levels across listening conditions and stimuli. These data demonstrate that the P3 response with its associated cortical oscillations represents a potential neurophysiological marker for speech perception in noise. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Quality-aware features-based noise level estimator for block matching and three-dimensional filtering algorithm

    Science.gov (United States)

    Xu, Shaoping; Hu, Lingyan; Yang, Xiaohui

    2016-01-01

    The performance of conventional denoising algorithms is usually controlled by one or several parameters whose optimal settings depend on the contents of the processed images and the characteristics of the noises. Among these parameters, noise level is a fundamental parameter that is always assumed to be known by most of the existing denoising algorithms (so-called nonblind denoising algorithms), which largely limits the applicability of these nonblind denoising algorithms in many applications. Moreover, these nonblind algorithms do not always achieve the best denoised images in visual quality even when fed with the actual noise level parameter. To address these shortcomings, in this paper we propose a new quality-aware features-based noise level estimator (NLE), which consists of quality-aware features extraction and optimal noise level parameter prediction. First, considering that image local contrast features convey important structural information that is closely related to image perceptual quality, we utilize the marginal statistics of two local contrast operators, i.e., the gradient magnitude and the Laplacian of Gaussian (LOG), to extract quality-aware features. The proposed quality-aware features have very low computational complexity, making them well suited for time-constrained applications. Then we propose a learning-based framework where the noise level parameter is estimated based on the quality-aware features. Based on the proposed NLE, we develop a blind block matching and three-dimensional filtering (BBM3D) denoising algorithm which is capable of effectively removing additive white Gaussian noise, even coupled with impulse noise. The noise level parameter of the BBM3D algorithm is automatically tuned according to the quality-aware features, guaranteeing the best performance. As such, the classical block matching and three-dimensional algorithm can be transformed into a blind one in an unsupervised manner. Experimental results demonstrate that the

  19. Seasonal variation of seismic ambient noise level at King Sejong Station, Antarctica

    Science.gov (United States)

    Lee, W.; Sheen, D.; Seo, K.; Yun, S.

    2009-12-01

    The generation of the secondary- or double-frequency (DF) microseisms with dominant frequencies between 0.1 and 0.5 Hz has been explained by nonlinear second-order pressure perturbations on the ocean bottom due to the interference of two ocean waves of equal wavelengths traveling in opposite directions. Korea Polar Research Institute (KOPRI) has been operating a broadband seismic station (KSJ1) at King George Island (KGI), Antarctica, since 2001. Examining the ambient seismic noise level for the period from 2006 to 2008 at KSJ1, we found a significant seasonal variation in the frequency range 0.1-0.5 Hz. Correlation of the DF peaks with significant ocean wave height and peak wave period models indicates that the oceanic infragravity waves in the Drake Passage is a possible source to excite the DF microseisms at KGI. Location of King Sejong Station, Antarctica Seasonal variations of DF peak, significant wave height, and peak wave period

  20. Increased noise levels have different impacts on the anti-predator behaviour of two sympatric fish species.

    Directory of Open Access Journals (Sweden)

    Irene K Voellmy

    Full Text Available Animals must avoid predation to survive and reproduce, and there is increasing evidence that man-made (anthropogenic factors can influence predator-prey relationships. Anthropogenic noise has been shown to have a variety of effects on many species, but work investigating the impact on anti-predator behaviour is rare. In this laboratory study, we examined how additional noise (playback of field recordings of a ship passing through a harbour, compared with control conditions (playback of recordings from the same harbours without ship noise, affected responses to a visual predatory stimulus. We compared the anti-predator behaviour of two sympatric fish species, the three-spined stickleback (Gasterosteus aculeatus and the European minnow (Phoxinus phoxinus, which share similar feeding and predator ecologies, but differ in their body armour. Effects of additional-noise playbacks differed between species: sticklebacks responded significantly more quickly to the visual predatory stimulus during additional-noise playbacks than during control conditions, while minnows exhibited no significant change in their response latency. Our results suggest that elevated noise levels have the potential to affect anti-predator behaviour of different species in different ways. Future field-based experiments are needed to confirm whether this effect and the interspecific difference exist in relation to real-world noise sources, and to determine survival and population consequences.

  1. The effect of extending high-frequency bandwidth on the acceptable noise level (ANL) of hearing-impaired listeners.

    Science.gov (United States)

    Johnson, Earl; Ricketts, Todd; Hornsby, Benjamin

    2009-01-01

    This study examined the effects of extending high-frequency bandwidth, for both a speech signal and a background noise, on the acceptable signal-to-noise ratio (SNR) of listeners with mild sensorineural hearing loss through utilization of the Acceptable Noise Level (ANL) procedure. In addition to extending high-frequency bandwidth, the effects of reverberation time and background noise type and shape were also examined. The study results showed a significant increase in the mean ANL (i.e. participants requested a better SNR for an acceptable listening situation) when high-frequency bandwidth was extended from 3 to 9 kHz and from 6 to 9 kHz. No change in the ANL of study participants was observed as a result of isolated modification to reverberation time or background noise stimulus. An interaction effect, however, of reverberation time and background noise stimulus was demonstrated. These findings may have implications for future design of hearing aid memory programs for listening to speech in the presence of broadband background noise.

  2. Maximizing noise energy for noise-masking studies.

    Science.gov (United States)

    Jules Étienne, Cédric; Arleo, Angelo; Allard, Rémy

    2017-08-01

    Noise-masking experiments are widely used to investigate visual functions. To be useful, noise generally needs to be strong enough to noticeably impair performance, but under some conditions, noise does not impair performance even when its contrast approaches the maximal displayable limit of 100 %. To extend the usefulness of noise-masking paradigms over a wider range of conditions, the present study developed a noise with great masking strength. There are two typical ways of increasing masking strength without exceeding the limited contrast range: use binary noise instead of Gaussian noise or filter out frequencies that are not relevant to the task (i.e., which can be removed without affecting performance). The present study combined these two approaches to further increase masking strength. We show that binarizing the noise after the filtering process substantially increases the energy at frequencies within the pass-band of the filter given equated total contrast ranges. A validation experiment showed that similar performances were obtained using binarized-filtered noise and filtered noise (given equated noise energy at the frequencies within the pass-band) suggesting that the binarization operation, which substantially reduced the contrast range, had no significant impact on performance. We conclude that binarized-filtered noise (and more generally, truncated-filtered noise) can substantially increase the energy of the noise at frequencies within the pass-band. Thus, given a limited contrast range, binarized-filtered noise can display higher energy levels than Gaussian noise and thereby widen the range of conditions over which noise-masking paradigms can be useful.

  3. Characterizing the relative contributions of large vessels to total ocean noise fields: a case study using the Gerry E. Studds Stellwagen Bank National Marine Sanctuary.

    Science.gov (United States)

    Hatch, Leila; Clark, Christopher; Merrick, Richard; Van Parijs, Sofie; Ponirakis, Dimitri; Schwehr, Kurt; Thompson, Michael; Wiley, David

    2008-11-01

    In 2006, we used the U.S. Coast Guard's Automatic Identification System (AIS) to describe patterns of large commercial ship traffic within a U.S. National Marine Sanctuary located off the coast of Massachusetts. We found that 541 large commercial vessels transited the greater sanctuary 3413 times during the year. Cargo ships, tankers, and tug/tows constituted 78% of the vessels and 82% of the total transits. Cargo ships, tankers, and cruise ships predominantly used the designated Boston Traffic Separation Scheme, while tug/tow traffic was concentrated in the western and northern portions of the sanctuary. We combined AIS data with low-frequency acoustic data from an array of nine autonomous recording units analyzed for 2 months in 2006. Analysis of received sound levels (10-1000 Hz, root-mean-square pressure re 1 microPa +/- SE) averaged 119.5 +/- 0.3 dB at high-traffic locations. High-traffic locations experienced double the acoustic power of less trafficked locations for the majority of the time period analyzed. Average source level estimates (71-141 Hz, root-mean-square pressure re 1 microPa +/- SE) for individual vessels ranged from 158 +/- 2 dB (research vessel) to 186 +/- 2 dB (oil tanker). Tankers were estimated to contribute 2 times more acoustic power to the region than cargo ships, and more than 100 times more than research vessels. Our results indicate that noise produced by large commercial vessels was at levels and within frequencies that warrant concern among managers regarding the ability of endangered whales to maintain acoustic contact within greater sanctuary waters.

  4. Current Background Noise Sources and Levels in the NASA Ames 40- by 80-Foot Wind Tunnel: A Status Report

    Science.gov (United States)

    Allen, Christopher S.; Jaeger, Stephen; Soderman, Paul; Koga, Dennis (Technical Monitor)

    1999-01-01

    Background noise measurements were made of the acoustic environment in the National Full-Scale Aerodynamics Complex 40- by 80-Foot Wind Tunnel (40x80) at NASA Ames Research Center. The measurements were acquired subsequent to the 40x80 Aeroacoustic Modernization Project, which was undertaken to improve the anechoic characteristics of the 40x80's closed test section as well as reduce the levels of background noise in the facility. The resulting 40x80 anechoic environment was described by Soderman et. al., and the current paper describes the resulting 40x80 background noise, discusses the sources of the noise, and draws comparisons to previous 40x80 background noise levels measurements. At low wind speeds or low frequencies, the 40x80 background noise is dominated by the fan drive system. To obtain the lowest fan drive noise for a given tunnel condition, it is possible in the 40x80 to reduce the fans' rotational speed and adjust the fans' blade pitch, as described by Schmidtz et. al. This idea is not new, but has now been operationally implemented with modifications for increased power at low rotational speeds. At low to mid-frequencies and at higher wind speeds, the dominant noise mechanism was thought to be caused by the surface interface of the previous test section floor acoustic lining. In order to reduce this noise mechanism, the new test section floor lining was designed to resist the pumping of flow in and out of the space between the grating slats required to support heavy equipment. In addition, the lining/flow interface over the entire test section was designed to be smoother and quieter than the previous design. At high wind speeds or high frequencies, the dominant source of background noise in the 40x80 is believed to be caused by the response of the in-flow microphone probes (required by the nature of the closed test section) to the fluctuations in the freestream flow. The resulting background noise levels are also different for probes of various

  5. GLUCOSE AND TOTAL PROTEIN LEVEL IN LABORATORY RATS UNDER CONDITIONS OF SHORT-TERM FASTING

    Directory of Open Access Journals (Sweden)

    Damir Suljević

    2013-09-01

    Full Text Available Glucose level (UV enzymatic method and total protein level (Biuret method were measured in the blood samples of the rats exposed to short-term starvation. We found a statistically significant increase in the glucose level in experimental animals during starvation, which is also evident in males and females in the experimental group (p <0.05, while decrease in the total protein level was not statistically significant. During starvation, more significant weight loss was observed in females compared to males.Key words: glucose, total protein, serum, Rattus

  6. Ambient seismic noise levels: A survey of the permanent and temporary seismographic networks in Morocco, North Africa

    Science.gov (United States)

    El Fellah, Y.; Khairy Abd Ed-Aal, A.; El Moudnib, L.; Mimoun, H.; Villasenor, A.; Gallart, J.; Thomas, C.; Elouai, D.; Mimoun, C.; Himmi, M.

    2013-12-01

    Abstract The results, of a conducted study carried out to analyze variations in ambient seismic noise levels at sites of the installed broadband stations in Morocco, North Africa, are obtained. The permanent and the temporary seismic stations installed in Morocco of the Scientific Institute ( IS, Rabat, Morocco), institute de Ciencias de la Tierra Jaume almera (ICTJA, Barcelona, Spain) and Institut für Geophysik (Munster, Germany) were used in this study. In this work, we used 23 broadband seismic stations installed in different structural domains covering all Morocco from south to north. The main purposes of the current study are: 1) to present a catalog of seismic background noise spectra for Morocco obtained from recently installed broadband stations, 2) to assess the effects of experimental temporary seismic vault construction, 3) to determine the time needed for noise at sites to stabilize, 4) to establish characteristics and origin of seismic noise at those sites. We calculated power spectral densities of background noise for each component of each broadband seismometer deployed in the different investigated sites and then compared them with the high-noise model and low-noise Model of Peterson (1993). All segments from day and night local time windows were included in the calculation without parsing out earthquakes. The obtained results of the current study could be used forthcoming to evaluate permanent station quality. Moreover, this study could be considered as a first step to develop new seismic noise models in North Africa not included in Peterson (1993). Keywords Background noise; Power spectral density; Model of Peterson; Scientific Institute; Institute de Ciencias de la Tierra Jaume almera; Institut für Geophysik

  7. On Noise Generation and Dynamic Transmission Error of Gears

    OpenAIRE

    Henriksson, Mats

    2009-01-01

    Noise from heavy trucks is an important environmental issue. Several sources contribute to the total noise level of a vehicle, such as the engine, gearbox, tires, etc. The tonal noise from the gearbox can be very disturbing for the driver, even if the noise level from the gearbox is lower than the total noise level. The human ear has a remarkable way of detecting pure tones of which the noise from loaded gears consists of. To be allowed to sell a heavy truck within the European Union, the so ...

  8. Underwater and Dive Station Work-Site Noise Surveys

    National Research Council Canada - National Science Library

    Wolgemuth, Keith S; Cudahy, Edward A; Schwaller, Derek W

    2008-01-01

    ...) data This study extends this previous work by obtaining in-water and in-air noise measurements and a total noise dose for Navy divers during actual diving operations using a portable sound level...

  9. Hearing Threshold and Equal Loudness Level Contours of 1/3-octave Noise Bands in a Diffuse Sound Field

    DEFF Research Database (Denmark)

    Nielsen, Maja Kirstine E.; Poulsen, Torben

    1994-01-01

    Hearing threshold levels and equal loudness level contours of 1/3-octave noise bands at 40 phons and 60 phon were measured for 27 normal hearing listeners in an approximately diffuse sound field. The threshold data in the frequency range 125 Hz to 1 kHz were 3-6 dB higher than the values given...

  10. Total levels of hippocampal histone acetylation predict normal variability in mouse behavior.

    Directory of Open Access Journals (Sweden)

    Addie May I Nesbitt

    Full Text Available Genetic, pharmacological, and environmental interventions that alter total levels of histone acetylation in specific brain regions can modulate behaviors and treatment responses. Efforts have been made to identify specific genes that are affected by alterations in total histone acetylation and to propose that such gene specific modulation could explain the effects of total histone acetylation levels on behavior - the implication being that under naturalistic conditions variability in histone acetylation occurs primarily around the promoters of specific genes.Here we challenge this hypothesis by demonstrating with a novel flow cytometry based technique that normal variability in open field exploration, a hippocampus-related behavior, was associated with total levels of histone acetylation in the hippocampus but not in other brain regions.Results suggest that modulation of total levels of histone acetylation may play a role in regulating biological processes. We speculate in the discussion that endogenous regulation of total levels of histone acetylation may be a mechanism through which organisms regulate cellular plasticity. Flow cytometry provides a useful approach to measure total levels of histone acetylation at the single cell level. Relating such information to behavioral measures and treatment responses could inform drug delivery strategies to target histone deacetylase inhibitors and other chromatin modulators to places where they may be of benefit while avoiding areas where correction is not needed and could be harmful.

  11. Enhancing the management of the noise level using six sigma method: a case study on the machining industry

    Science.gov (United States)

    Rimantho, D.; Hanantya, M. W.

    2017-12-01

    The hearing disorder is caused by noises in the workplace, it has been a concern for numerous researchers. This study aims to improve the performance of the management of the noise level by applying the six sigma method. Data collection is done directly by using a sound level meter. In addition, several key informants also used in order to gather information related to the problem. The results showed the values of Cp and Cpk on the entire department are still below the recommended value. Moreover, the results also showed the potential failure (DPMO) approximately 115,260.6 and equivalent to the Sigma value is approximately 2.70. Furthermore, the highest value of the RPN in FMEA analysis is the workers not wear factor of earplug which is about 56. Thus, it is necessary to make enhancements to the process of managing the noise level in the framework of continuous improvement.

  12. Noise exposure in movie theaters: a preliminary study of sound levels during the showing of 25 films.

    Science.gov (United States)

    Warszawa, Anna; Sataloff, Robert T

    2010-09-01

    The harmful effects of noise exposure during leisure-time activities are beginning to receive some scrutiny. We conducted a preliminary study to investigate the noise levels during the showings of 25 different films. During each screening, various sound measurements were made with a dosimeter. The movies were classified on the basis of both their Motion Picture Association of America (MPAA) rating and their genre, and the size of the theater and the size of the audience were taken into consideration in the final analysis. Our findings suggest that the sound levels of many movies might be harmful to hearing, although we can draw no definitive conclusions. We did not discern any relationship between noise levels and either MPAA rating or genre. Further studies are recommended.

  13. Serum levels of total IgE and soluble CD23 in bronchial asthma

    Directory of Open Access Journals (Sweden)

    G. Di Lorenzo

    1996-01-01

    Full Text Available The aim of the present study was to compare, during the pollen season, serum levels of total IgE and soluble CD23 (sCD23 from patients with allergic bronchial asthma, with those from healthy subjects. Significantly higher levels of total IgE and sCD23 were found in patients with asthma compared to the control group. Both in normal controls and in asthmatic patients, a significant correlation was shown between the levels of these two molecules. In asthmatic patients, significant correlations were found for both total IgE and sCD23, with lung function measured as bronchial responsiveness to inhaled methacholine. These results suggest that in asthmatic patients, in addition to the study of total serum IgE levels, the assessment of sCD23 serum levels may be helpful in the evaluation of disease activity.

  14. Is there any relationship between serum levels of total bilirubin and the severity of erectile dysfunction?

    Science.gov (United States)

    Keskin, Ercüment; Karabakan, Mehmet; Bozkurt, Aliseydi; Hirik, Erkan; Karabulut, İbrahim; Gunay, Murat; Çakan, Murat

    2018-04-01

    Recent studies have shown that atherosclerosis is associated with erectile dysfunction and the serum bilirubin level. In this study, the serum total bilirubin levels of patients with erectile dysfunction were measured to investigate the relationship between the levels of erectile dysfunction and total bilirubin. A total of 94 patients with erectile dysfunction were divided into three groups; severe erectile dysfunction (33 patients), moderate erectile dysfunction (31 patients), and mild erectile dysfunction (30 patients). In addition, a control group was formed with 31 healthy men. The International Index of Erectile Function-5 Questionnaire was used to measure the quality of erection in all the groups. The body mass index was calculated for all the participants. The serum glucose, low-density lipoprotein and high-density lipoprotein, cholesterol, triglyceride, total bilirubin, and total testosterone levels were also determined. No statistically significant difference was observed between the groups in terms of the mean age, hypertension, smoking status, alcohol use, cardiovascular diseases, hepatobiliary disease, diabetes mellitus, and levels of total testosterone, low-density lipoprotein-cholesterol, and triglyceride. However, high-density lipoprotein, body mass index, and total bilirubin were significantly lower compared to the control group (p < 0.001). The serum total bilirubin level was found to be 0.41 ± 0.21 ng/dL in the severe erectile dysfunction, 0.43 ± 0.19 ng/dL in the moderate erectile dysfunction, and 0.48 ± 0.11 ng/dL in the mild erectile dysfunction groups (p < 0.001). Considering the significant differences between the erectile dysfunction and control groups in terms of serum total bilirubin levels, a low level of bilirubin may have a role in the etiology of erectile dysfunction.

  15. Feedback damping of a microcantilever at room temperature to the minimum vibration amplitude limited by the noise level.

    Science.gov (United States)

    Kawamura, Y; Kanegae, R

    2016-06-17

    Cooling the vibration amplitude of a microcantilever as low as possible is important to improve the sensitivity and resolutions of various types of scanning type microscopes and sensors making use of it. When the vibration amplitude is controlled to be smaller using a feed back control system, it is known that the obtainable minimum amplitude of the vibration is limited by the floor noise level of the detection system. In this study, we demonstrated that the amplitude of the thermal vibration of a microcantilever was suppressed to be about 0.15 pmHz(-1/2), which is the same value with the floor noise level, without the assistance of external cryogenic cooling. We think that one of the reason why we could reach the smaller amplitude at room temperature is due to stiffer spring constant of the lever, which leads to higher natural frequency and consequently lower floor noise level. The other reason is considered to be due to the increase in the laser power for the diagnostics, which lead to the decrease in the signal to noise ratio determined by the optical shot noise.

  16. Total and antigen-specific Ige levels in umbilical cord blood

    Directory of Open Access Journals (Sweden)

    Sybilski AJ

    2009-12-01

    Full Text Available Abstract The present study was conducted to learn whether the perinatal and environmental factors could influence the total and antigen-specific IgE levels in umbilical cord blood. Retrospective data were obtained from 173 mother-infant pairs. Total and specific (for children's food, wheat/grass and house dust mite-HDM cord blood IgE levels were determined using the immunoassay test. The total cord blood IgE was between 0.0-23.08 IU/ml (mean 0.55 ± 2.07 IU/ml; median 0.16 IU/ml. Total IgE levels were significantly higher in boys compared with girls (OR = 2.2; P = 0.007, and in newborns with complicated pregnancy (OR = 2.7; P = 0.003. A greater number of siblings correlated with increases in the total cord blood IgE (P

  17. Aircraft and background noise annoyance effects

    Science.gov (United States)

    Willshire, K. F.

    1984-01-01

    To investigate annoyance of multiple noise sources, two experiments were conducted. The first experiment, which used 48 subjects, was designed to establish annoyance-noise level functions for three community noise sources presented individually: jet aircraft flyovers, air conditioner, and traffic. The second experiment, which used 216 subjects, investigated the effects of background noise on aircraft annoyance as a function of noise level and spectrum shape; and the differences between overall, aircraft, and background noise annoyance. In both experiments, rated annoyance was the dependent measure. Results indicate that the slope of the linear relationship between annoyance and noise level for traffic is significantly different from that of flyover and air conditioner noise and that further research was justified to determine the influence of the two background noises on overall, aircraft, and background noise annoyance (e.g., experiment two). In experiment two, total noise exposure, signal-to-noise ratio, and background source type were found to have effects on all three types of annoyance. Thus, both signal-to-noise ratio, and the background source must be considered when trying to determine community response to combined noise sources.

  18. A study of the effect of flight density and background noise on V/STOL acceptability. [effective perceived noise level as measure of annoyance

    Science.gov (United States)

    Sternfeld, H., Jr.; Hinterkeuser, E. G.; Hackman, R. B.; Davis, J.

    1974-01-01

    A study was conducted in which test subjects evaluated the sounds of a helicopter, a turbofan STOL and a turbojet airplane while engaged in work and leisure activities. Exposure to a high repetitive density of the aircraft sounds did not make the individual sounds more annoying but did create an unacceptable environment. The application of a time duration term to db(A) resulted in a measure which compared favorably with EPNL as a predictor of annoyance. Temporal variations in background noise level had no significant effect on the rated annoyance.

  19. Arterial indices and serum cystatin C level in individuals with occupational wide band noise exposure

    Directory of Open Access Journals (Sweden)

    Ali R Khoshdel

    2016-01-01

    Full Text Available Background: Chronic exposure to noise is known to cause a wide range of health problems including extracellular matrix (ECM proliferation and involvement of cardiovascular system. There are a few studies to investigate noise-induced vascular changes using noninvasive methods. In this study we used carotid artery intima-media thickness (CIMT and aortic augmentation as indices of arterial properties and cystatin C as a serum biomarker relating to ECM metabolism. Materials and Methods: Ninety-three male participants were included in this study from aeronautic technicians: 39 with and 54 without a history of wide band noise (WBN exposure. For better discrimination, the participants were divided into the two age groups: 40 years old. Adjusted aortic augmentation index (AI for a heart rate equal to 75 beats per minute (AIx@HR75 were calculated using pulse wave analysis (PWA. CIMT was measured in 54 participants who accepted to undergo Doppler ultrasonography. Serum cystatin C was also measured. Results: Among younger individuals the mean CIMT was 0.85 ± 0.09 mm and 0.75 ± 0.22 mm in the in the exposed and the control groups respectively. Among older individuals CIMT had a mean of 1.04 ± 0.22 mm vs. 1.00 ± 0.25 mm for the exposed vs. the control group. However, in both age groups the difference was not significant at the 0.05 level. A comparison of AIx@HR75 between exposure group and control group both in younger age group (5.46 ± 11.22 vs. 8.56 ± 8.66 and older age group (17.55 ± 10.07 vs. 16.61 ± 5.77 revealed no significant difference. We did not find any significant correlation between CIMT and AIx@HR75 in exposed group (r = 0.314, P value = 0.145 but the correlation was significant in control group (r = 0.455, P value = 0.019. Serum cystatin C level was significantly lower in individuals with WBN exposure compared to controls (441.10 ± 104.70 ng/L vs. 616.89 ± 136.14, P

  20. Acceptance noise level: effects of the speech signal, babble, and listener language.

    Science.gov (United States)

    Shi, Lu-Feng; Azcona, Gabrielly; Buten, Lupe

    2015-04-01

    The acceptable noise level (ANL) measure has gained much research/clinical interest in recent years. The present study examined how the characteristics of the speech signal and the babble used in the measure may affect the ANL in listeners with different native languages. Fifteen English monolingual, 16 Russian-English bilingual, and 24 Spanish-English bilingual listeners participated. The ANL was obtained in eight conditions varying in the language of the signal (English and Spanish), language of the babble (English and Spanish), and number of talkers in the babble (4 and 12). Test conditions were randomized across listeners. The ANL for each condition was based on a minimum of two trials. Russian-English bilinguals yielded higher ANLs than other listeners; the intergroup difference of 4-5 dB was statistically and clinically significant. Spanish signals yielded significantly higher ANLs than English signals, but this difference of 0.5 dB was clinically negligible. The language and composition of the babble had a significant effect on Russian-English bilinguals, who yielded higher ANLs with the Spanish than English 12-talker babble. The above findings do not fully support the notion that the ANL is language- and population-independent. Clinicians should be aware of possible effects on ANL measures due to listeners' linguistic/cultural background.

  1. Noise annoyance from stationary sources: Relationships with exposure metric day-evening-night level (DENL) and their confidence intervals

    NARCIS (Netherlands)

    Miedema, H.M.E.; Vos, H.

    2004-01-01

    Relationships between exposure to noise [metric: day-evening-night levels (DENL)] from stationary sources (shunting yards, a seasonal industry, and other industries) and annoyance are presented. Curves are presented for expected annoyance score, the percentage "highly annoyed" (%HA, cutoff at 72 on

  2. Choosing channel quantization levels and viterbi decoding for space diversity reception over the additive white Guassian noise channel

    Science.gov (United States)

    Kalson, S.

    1986-01-01

    Previous work in the area of choosing channel quantization levels for a additive white Gaussian noise channel composed of one receiver-demodulator is reviewed, and how this applies to the Deep Space Network composed of several receiver-demodulators (space diversity reception) is shown. Viterbi decoding for the resulting quantized channel is discussed.

  3. Serum total bilirubin levels and coronary heart disease--Causal association or epiphenomenon?

    Science.gov (United States)

    Kunutsor, Setor K

    2015-12-01

    Observational epidemiological evidence supports a linear inverse and independent association between serum total bilirubin levels and coronary heart disease (CHD) risk, but whether this association is causal remains to be ascertained. A Mendelian randomization approach was employed to test whether serum total bilirubin is causally linked to CHD. The genetic variant rs6742078--well known to specifically modify levels of serum total bilirubin and accounting for up to 20% of the variance in circulating serum total bilirubin levels--was used as an instrumental variable. In pooled analysis of estimates reported from published genome-wide association studies, every copy of the T allele of rs6742078 was associated with 0.42 standard deviation (SD) higher levels of serum total bilirubin (95% confidence interval, 0.40 to 0.43). Based on combined data from the Coronary Artery Disease Genome wide Replication and Meta-analyses and the Coronary Artery Disease (C4D) Genetics Consortium involving a total of 36,763 CHD cases and 76,997 controls, the odds ratio for CHD per copy of the T allele was 1.01 (95% confidence interval, 0.99 to 1.04). The odds ratio of CHD for a 1 SD genetically elevated serum total bilirubin level was 1.03 (95% confidence interval, 0.98 to 1.09). The current findings casts doubt on a strong causal association of serum total bilirubin levels with CHD. The inverse associations demonstrated in observational studies may be driven by biases such as unmeasured confounding and/or reverse causation. However, further research in large-scale consortia is needed. Copyright © 2015 Elsevier Inc. All rights reserved.

  4. Total mercury levels in commercial fish species from Italian fishery and aquaculture.

    Science.gov (United States)

    Di Lena, Gabriella; Casini, Irene; Caproni, Roberto; Fusari, Andrea; Orban, Elena

    2017-06-01

    Total mercury levels were measured in 42 commercial fish species caught off the Central Adriatic and Tyrrhenian coasts of Italy and in 6 aquaculture species. The study on wild fish covered species differing in living habitat and trophic level. The study on farmed fish covered marine and freshwater species from intensive and extensive aquaculture and their feed. Mercury levels were analysed by thermal decomposition-amalgamation-atomic absorption spectrophotometry. Total mercury concentrations in the muscle of wild fish showed a high variability among species (0.025-2.20 mg kg -1 wet weight). The lowest levels were detected in low trophic-level demersal and pelagic-neritic fish and in young individuals of high trophic-level species. Levels exceeding the European Commission limits were found in large-size specimens of high trophic-level pelagic and demersal species. Fish from intensive farming showed low levels of total mercury (0.008-0.251 mg kg -1 ). Fish from extensive rearing showed variable contamination levels, depending on the area of provenience. An estimation of the human intake of mercury associated to the consumption of the studied fish and its comparison with the tolerable weekly intake is provided.

  5. Total proteins and protein fractions levels in pregnant rats subjected to whole-body gamma irradiation

    International Nuclear Information System (INIS)

    Mansour, M.A.; Roushdy, H.M.; Mazhar, F.M.; Abu-Gabal, H.A.

    1986-01-01

    A total number of 180 mature rats (120 females and 60 males) weighing from 120-140 g were used to study the effect of two doses (2 and 4 Gy) whole-body gamma irradiation on the level of total protein and protein fractions in serum of pregnant rats during the period of organogenesis. It was found that the levels of total protein, albumin and gamma globulins significantly decreased according to the doses of exposure. The levels of alpha and beta globulins significantly increased more in the serum of rats exposed to 2 Gy than in rats exposed to 4 Gy. The level of A/G ratio significantly decreased more in the serum of rats exposed to 2Gy than in those exposed to 4 Gy

  6. Comparison of clinical parameters and environmental noise levels between regular surgery and piezosurgery for extraction of impacted third molars.

    Science.gov (United States)

    Chang, Hao-Hueng; Lee, Ming-Shu; Hsu, You-Chyun; Tsai, Shang-Jye; Lin, Chun-Pin

    2015-10-01

    Impacted third molars can be extracted by regular surgery or piezosurgery. The aim of this study was to compare clinical parameters and device-produced noise levels between regular surgery and piezosurgery for the extraction of impacted third molars. Twenty patients (18 women and 2 men, 17-29 years of age) with bilateral symmetrical impacted mandibular or maxillary third molars of the same level were included in this randomized crossover clinical trial. The 40 impacted third molars were divided into a control group (n = 20), in which the third molar was extracted by regular surgery using a high-speed handpiece and an elevator, and an experimental group (n = 20), in which the third molar was extracted by piezosurgery using a high-speed handpiece and a piezotome. The clinical parameters were evaluated by a self-reported questionnaire. The noise levels produced by the high-speed handpiece and piezotome were measured and compared between the experimental and control groups. Patients in the experimental group had a better feeling about tooth extraction and force delivery during extraction and less facial swelling than patients in the control group. However, there were no significant differences in noise-related disturbance, extraction period, degree of facial swelling, pain score, pain duration, any noise levels produced by the devices under different circumstances during tooth extraction between the control and experimental groups. The piezosurgery device produced noise levels similar to or lower than those of the high-speed drilling device. However, piezosurgery provides advantages of increased patient comfort during extraction of impacted third molars. Copyright © 2014. Published by Elsevier B.V.

  7. Reorganization of auditory map and pitch discrimination in adult rats chronically exposed to low-level ambient noise

    Directory of Open Access Journals (Sweden)

    Weimin eZheng

    2012-09-01

    Full Text Available Behavioral adaption to a changing environment is critical for an animal’s survival. How well the brain can modify its functional properties based on experience essentially defines the limits of behavioral adaptation. In adult animals the extent to which experience shapes brain function has not been fully explored. Moreover, the perceptual consequences of experience-induced changes in the brains of adults remain unknown. Here we show that the tonotopic map in the primary auditory cortex of adult rats living with low-level ambient noise underwent a dramatic reorganization. Behaviorally, chronic noise-exposure impaired fine, but not coarse pitch discrimination. When tested in a noisy environment, the noise-exposed rats performed as well as in a quiet environment whereas the control rats performed poorly. This suggests that noise-exposed animals had adapted to living in a noisy environment. Behavioral pattern analyses revealed that stress or distraction engendered by the noisy background could not account for the poor performance of the control rats in a noisy environment. A reorganized auditory map may therefore have served as the neural substrate for the consistent performance of the noise-exposed rats in a noisy environment.

  8. [Evaluation of strategies aimed at reducing the level of noise in different areas of neonatal care in a tertiary hospital].

    Science.gov (United States)

    Nieto-Sanjuanero, Adriana; Quero-Jiménez, José; Cantú-Moreno, Daniel; Rodríguez-Balderrama, Isaías; Montes-Tapia, Fernando; Rubio-Pérez, Nadina; Treviño-Garza, Consuelo; de la O-Cavazos, Manuel

    2015-01-01

    To determine the noise levels of different areas responsible for newborn care, develop intervention strategies to decrease the noise, and evaluate its effectiveness. Prospective, observational and longitudinal study carried out using a sonometer, measuring sound levels for three weeks in the neonatal intensive care unit (NICU), neonatal intermediate care unit (UCIREN), delivery (TOCO QX) and nursery (CUNERO) units. We implemented an intervention program and subsequent measurements were performed under the same initial conditions. When comparing the decibel levels in different areas during the three weeks, pre- and post-intervention, we found at the neonatal intensive care unit 59.9±4.8 vs. 56.4±4.7 dB (pTOCO QX, so the intervention program was effective in these areas; however, the decibel levels registered continue above those recommended by international standards.

  9. Blood trihalomethane levels and the risk of total cancer mortality in US adults

    International Nuclear Information System (INIS)

    Min, Jin-Young; Min, Kyoung-Bok

    2016-01-01

    Background: Although animal data have suggested the carcinogenic activity of trihalomethanes (THMs), there is inconsistent evidence supporting the link between THM exposure and cancers in humans. Objectives: We investigated the association between specific and total blood THM levels with the risk of total cancer mortality in adults. Methods: We analyzed data from the 1999–2004 Third National Health and Nutrition Examination Survey and the Linked Mortality File of the United States. A total of 933 adults (20–59 years of age) with available blood THM levels and no missing data for other variables were included. Four different THM species (chloroform, bromodichloromethane (BDCM), dibromochloromethane (DBCM) and bromoform) were included, and the codes associated with cancer (malignant neoplasm) were C00 through C97, based on the underlying causes of death listed in the International Classification of Disease 10the Revision. Results: Compared with adults in the lowest DBCM, bromoform, and total brominated THM tertiles, those in the highest DBCM, bromoform, and total brominated THM tertiles exhibited adjusted hazard ratios (HR) of total cancer mortality of 4.97 (95% confidence interval (CI) = 1.59–15.50), 4.94 (95% CI = 1.56–15.61), and 3.42 (95% CI = 1.21–15.43) respectively. The risk of total cancer mortality was not associated with increases in blood chloroform and total THM levels. Conclusions: We found that the baseline blood THM species, particularly brominated THMs, were significantly associated with total cancer mortality in adults. Although this study should be confirm by other studies, our findings suggest a possible link between THM exposures and cancer. - Highlights: • Trihalomethanes (THM) are classified as either probable or possible carcinogens. • Limited evidence on the link between THM and the incidence of cancer in humans. • We investigated the association between blood THM levels and the risk of total cancer mortality. • High

  10. Variations in voice level and fundamental frequency with changing background noise level and talker-to-listener distance while wearing hearing protectors: A pilot study

    DEFF Research Database (Denmark)

    Bouserhal, Rachel E.; MacDonald, Ewen; Falk, Tiago H.

    2016-01-01

    in voice level and fundamental frequency in noise and with varying talker-to-listener distance. Study sample: Twelve participants with a mean age of 28 participated in this study. Results: Compared to existing data, results show a trend similar to the open ear condition with the exception of the occluded...

  11. Determinations of total residue, total oxide and density of high-level liquid waste (HLLW) by gravimetric method

    International Nuclear Information System (INIS)

    Li Yun; Gao Yueying; Yang Ming; Jin Liyun

    1992-01-01

    Gravimetric method for determination of total residue, total oxide and density of HLLW is developed. An aliquot of the original HLLW solution is piped on to the small quartz disc and put into the mini muffle furnace carefully. It is first heated to below 100 degree C (for 1.5 hours to remove the free water, and then heated to 180 degree C for 2 hours to remove the crystal water in a furnace. The total residue is weighed at room temperature. The precision is better than 3% for the determination of total residue and total oxide. An aliquot of the original HLLW solution is piped into the weighing bottle and weighed. The precision is better than 1%

  12. Comparison of clinical parameters and environmental noise levels between regular surgery and piezosurgery for extraction of impacted third molars

    OpenAIRE

    Chang, Hao-Hueng; Lee, Ming-Shu; Hsu, You-Chyun; Tsai, Shang-Jye; Lin, Chun-Pin

    2015-01-01

    Impacted third molars can be extracted by regular surgery or piezosurgery. The aim of this study was to compare clinical parameters and device-produced noise levels between regular surgery and piezosurgery for the extraction of impacted third molars. Methods: Twenty patients (18 women and 2 men, 17–29 years of age) with bilateral symmetrical impacted mandibular or maxillary third molars of the same level were included in this randomized crossover clinical trial. The 40 impacted third molar...

  13. Chicago transit authority train noise exposure.

    Science.gov (United States)

    Phan, Linh T; Jones, Rachael M

    2017-06-01

    To characterize noise exposure of riders on Chicago Transit Authority (CTA) trains, we measured noise levels twice on each segment of 7 of the 8 CTA train lines, which are named after colors, yielding 48 time-series measurements. We found the Blue Line has the highest noise levels compared to other train lines, with mean 76.9 dBA; and that the maximum noise level, 88.9 dBA occurred in the tunnel between the Chicago and Grand stations. Train segments involving travel through a tunnel had significantly higher noise levels than segments with travel on elevated and ground level tracks. While 8-hr doses inside the passenger cars were not estimated to exceed occupational exposure limits, train operators ride in a separate cab with operational windows and may therefore have higher noise exposures than riders. Despite the low risk of hearing loss for riders on CTA trains, in part because transit noise accounts for a small part of total daily noise exposure, 1-min average noise levels exceeded 85 dBA at times. This confirms anecdotal observations of discomfort due to noise levels, and indicates a need for noise management, particularly in tunnels.

  14. Normal levels of total body sodium and chlorine by neutron activation analysis

    International Nuclear Information System (INIS)

    Kennedy, N.S.J.; Eastell, R.; Smith, M.A.; Tothill, P.

    1983-01-01

    In vivo neutron activation analysis was used to measure total body sodium and chlorine in 18 male and 18 female normal adults. Corrections for body size were developed. Normalisation factors were derived which enable the prediction of the normal levels of sodium and chlorine in a subject. The coefficient of variation of normalised sodium was 5.9% in men and 6.9% in women, and of normalised chlorine 9.3% in men and 5.5% in women. In the range examined (40-70 years) no significant age dependence was observed for either element. Total body sodium was correlated with total body chlorine and total body calcium. Sodium excess, defined as the amount of body sodium in excess of that associated with chlorine, also correlated well with total body calcium. In females there was a mean annual loss of sodium excess of 1.2% after the menopause, similar to the loss of calcium. (author)

  15. Plasma levels of acylated and total ghrelin in pediatric patients with chronic kidney disease.

    Science.gov (United States)

    Naufel, Maria Fernanda Soares; Bordon, Milena; de Aquino, Talita Marques; Ribeiro, Eliane Beraldi; de Abreu Carvalhaes, João Tomás

    2010-12-01

    This cross-sectional study set out to compare total and acyl ghrelin levels in children with mild chronic kidney disease (CKD) undergoing conservative treatment (n = 19) with children with end-stage renal disease (ESRD) undergoing hemodialysis (n = 24), and with healthy controls (n = 20). The relationship between ghrelin levels and parameters of renal function, nutritional status, and selective hormones were investigated. ESRD patients had higher total ghrelin levels than those with mild CKD or control individuals. However, acyl ghrelin did not differ between groups, indicating that the excess circulating ghrelin was desacylated. Since desacyl ghrelin has been shown to inhibit appetite, increased levels might contribute to protein-energy wasting in pediatric renal patients. When all 43 renal patients were combined, multiple regression analysis found age and glomerular filtration rate (GFR) to be significant negative predictors of total ghrelin. Acyl ghrelin was influenced negatively by age and positively by energy intake. Acyl to total ghrelin ratio related positively to GFR and energy intake. The results indicate that total but not acyl ghrelin is influenced by low GFR in children with CKD and suggests that ghrelin activation may be impaired in these patients. Since energy intake is a positive predictor of acyl ghrelin, the physiological control of ghrelin secretion appears to be altered in pediatric renal patients.

  16. Recommendation of maximum allowable noise levels for offshore wind power systems; Empfehlung von Laermschutzwerten bei der Errichtung von Offshore-Windenergieanlagen (OWEA)

    Energy Technology Data Exchange (ETDEWEB)

    Werner, Stefanie [Umweltbundesamt, Dessau-Rosslau (Germany). Fachgebiet II 2.3

    2011-05-15

    When offshore wind farms are constructed, every single pile is hammered into the sediment by a hydraulic hammer. Noise levels at Horns Reef wind farm were in the range of 235 dB. The noise may cause damage to the auditory system of marine mammals. The Federal Environmental Office therefore recommends the definition of maximum permissible noise levels. Further, care should be taken that no marine mammals are found in the immediate vicinity of the construction site. (AKB)

  17. Total Variation-Based Reduction of Streak Artifacts, Ring Artifacts and Noise in 3D Reconstruction from Optical Projection Tomography

    Czech Academy of Sciences Publication Activity Database

    Michálek, Jan

    2015-01-01

    Roč. 21, č. 6 (2015), s. 1602-1615 ISSN 1431-9276 R&D Projects: GA MŠk(CZ) LH13028; GA ČR(CZ) GA13-12412S Institutional support: RVO:67985823 Keywords : optical projection tomography * microscopy * artifacts * total variation * data mismatch Subject RIV: EA - Cell Biology Impact factor: 1.730, year: 2015

  18. Cochlea hair cell rescue after a noise-induced hearing loss using a low level laser therapy (LLLT)

    Science.gov (United States)

    Rhee, Chung-Ku; Bahk, Chan Woong; Jung, Jae Yun; Ahn, Jin-Chul; Suh, Myung-Whan

    2011-03-01

    Aim: To see the effect of LLLT on noise-induced hearing loss. Methods: Eleven rats were exposed to noise (120 dB, 16 kHz, 6 h) and left ears were irradiated at 60J/cm2, 830 nm laser for 12 days. Right ears were control. Hearing levels were measured at frequencies of 4, 8, 12, 16, 32 kHz before noise exposure and after 12th irradiations. Results: The initial hearing levels were 26.5+/-4.7, 24.5+/-5.0, 24.0+/-5.2, 24.0+/-3.2, 24.5+/-5.5 dB SPL. After noise exposure, thresholds were 63.5+/-15.1, 64+/-16.8, 71.5+/-11.3, 73.5+/-15.6, 67.5+/-14.4 dB SPL in 4, 8, 12, 16, 32 kHz. After 12th irradiation, thresholds of treated ears recovered significantly 21+/-4.2, 20+/-3.5, 24+/-11.9, 24+/-12.9, 21+/-2.2 dB SPL and that of the untreated right ears measured 36.3+/-22.9, 45+/-15.8, 66.3+/-22.9, 50+/-16.8, 43.8+/-21.4 dB SPL. Conclusion: LLLT may promote recovery of hearing after noiseinduced hearing loss.

  19. Continuous monitoring of noise levels in the Gulf of Catania (Ionian Sea). Study of correlation with ship traffic.

    Science.gov (United States)

    Viola, S; Grammauta, R; Sciacca, V; Bellia, G; Beranzoli, L; Buscaino, G; Caruso, F; Chierici, F; Cuttone, G; D'Amico, A; De Luca, V; Embriaco, D; Favali, P; Giovanetti, G; Marinaro, G; Mazzola, S; Filiciotto, F; Pavan, G; Pellegrino, C; Pulvirenti, S; Simeone, F; Speziale, F; Riccobene, G

    2017-08-15

    Acoustic noise levels were measured in the Gulf of Catania (Ionian Sea) from July 2012 to May 2013 by a low frequency (<1000Hz) hydrophone, installed on board the NEMO-SN1 multidisciplinary observatory. NEMO-SN1 is a cabled node of EMSO-ERIC, which was deployed at a water depth of 2100m, 25km off Catania. The study area is characterized by the proximity of mid-size harbors and shipping lanes. Measured noise levels were correlated with the passage of ships tracked with a dedicated AIS antenna. Noise power was measured in the frequency range between 10Hz and 1000Hz. Experimental data were compared with the results of a fast numerical model based on AIS data to evaluate the contribution of shipping noise in six consecutive 1/3 octave frequency bands, including the 1/3 octave frequency bands centered at 63Hz and 125Hz, indicated by the Marine Strategy Framework Directive (2008/56/EC). Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  20. The effects of maternal total protein, albumin and hemoglobin levels on birth weight

    Directory of Open Access Journals (Sweden)

    Berna Haliloglu

    2007-12-01

    Full Text Available OBJECTIVE: The present study was designed to investigate the influence of third trimester maternal total protein, albumin, hemoglobin levels on birth weight.\tMATERIAL-METHOD: Between January 2005 and July 2005, 750 pregnant women applied for delivery at Zeynep Kamil Women’s and Children Education and Research Hospital at 37-40 week’s gestation were examined. Maternal total protein, albumin and hemoglobin levels were measured. Data included maternal age, gravidity, parity, gestational age, birth weight, gender, presence of iron supplementation and its duration.\tRESULTS: The birth weight was significantly higher in anemic and hypoproteinemic groups compared those with normal levels. After adjusting for counfounding factors, significance of both findings lost. The cases received iron supplementation had infants with higher birth weight, however, it was not statistically significant (p: 0.055. A significant positive relation was observed between birth weight and maternal age, gravidity, parity and gestational age. No relation found between maternal total protein, albumin, hemoglobin levels and birth weight.\tCONCLUSION: The last trimester maternal total protein, albumin, hemoglobin levels seem not to be a determining factor on infant's birth weight.

  1. A descriptive study of noise in the neonatal intensive care unit: ambient levels and perceptions of contributing factors.

    Science.gov (United States)

    Darcy, Ashley E; Hancock, Lauren E; Ware, Emily J

    2008-10-01

    To examine the baseline acoustic environment in several mid-Atlantic region neonatal intensive care units (NICUs) and investigate the perceived factors contributing to noise levels in these NICUs. Quantitative data were collected from 3 urban, mid-Atlantic level IIIB and level IIIC NICUs. Qualitative data were collected via interview from 2 RNs employed in each of the study NICUs. This was an exploratory descriptive study utilizing a mixed-methods approach. A quantitative method was used for sound-level data collection, and a qualitative method was utilized during interviews with nurses to examine perceptions of factors contributing to noise. Ambient sound levels, measured in decibels, were taken at 5-minute intervals over a 2-hour period during both day and night shifts in a central location at each NICU. In addition, nurses were interviewed using a standardized interview questionnaire, and these interviews were then reviewed to determine themes regarding perceived factors contributing to sound levels. Hourly mean sound levels in each NICU ranged from 53.9 dB to 60.6 dB, with no statistically significant difference between noise levels recorded on day shift versus night shift, and no statistically significant difference among sites. Qualitative data showed that nurses' believed day shift to be louder than night shift and many perceived their own NICU as "pretty quiet." Key contributing factors to increased sound levels were stated as monitors or alarms, performing invasive procedures, presence of family, nurses or doctors giving report or rounds, and ringing phones. Noise levels were found to be above the American Academy of Pediatrics-recommended 45-dB level and often louder than the 50-dB level, which should not be exceeded more than 10% of the time. The recommended impulse maximum of 65 dB was also exceeded. Environmental Protection Agency recommendations for hospitals include sound levels no louder than 35 dB on night shift; this standard was also violated

  2. A descriptive study of noise in the neonatal intensive care unit. Ambient levels and perceptions of contributing factors.

    Science.gov (United States)

    Darcy, Ashley E; Hancock, Lauren E; Ware, Emily J

    2008-06-01

    To examine the baseline acoustic environment in several mid-Atlantic region neonatal intensive care units (NICUs) and investigate the perceived factors contributing to noise levels in these NICUs. Quantitative data were collected from 3 urban, mid-Atlantic level IIIB and level IIIC NICUs. Qualitative data were collected via interview from 2 RNs employed in each of the study NICUs. This was an exploratory descriptive study utilizing a mixed-methods approach. A quantitative method was used for sound-level data collection, and a qualitative method was utilized during interviews with nurses to examine perceptions of factors contributing to noise. Ambient sound levels, measured in decibels, were taken at 5-minute intervals over a 2-hour period during both day and night shifts in a central location at each NICU. In addition, nurses were interviewed using a standardized interview questionnaire, and these interviews were then reviewed to determine themes regarding perceived factors contributing to sound levels. Hourly mean sound levels in each NICU ranged from 53.9 dB to 60.6 dB, with no statistically significant difference between noise levels recorded on day shift versus night shift, and no statistically significant difference among sites. Qualitative data showed that nurses' believed day shift to be louder than night shift and many perceived their own NICU as "pretty quiet." Key contributing factors to increased sound levels were stated as monitors or alarms, performing invasive procedures, presence of family, nurses or doctors giving report or rounds, and ringing phones. Noise levels were found to be above the American Academy of Pediatrics--recommended 45-dB level and often louder than the 50-dB level, which should not be exceeded more than 10% of the time. The recommended impulse maximum of 65 dB was also exceeded. Environmental Protection Agency recommendations for hospitals include sound levels no louder than 35 dB on night shift; this standard was also violated

  3. Total and ionized serum magnesium and calcium levels during magnesium sulfate administration for preterm labor

    Science.gov (United States)

    Kim, Won Hee; An, Yuna; Moon, Jong Ho; Noh, Eun Ji; Kim, Jong Woon

    2018-01-01

    Objective This study aimed to estimate the association between total and ionized magnesium, and the changes in serum magnesium and calcium levels in patients with preterm labor during magnesium sulfate (MgSO4) administration. Methods The study population included 64 women who were candidates for intravenous MgSO4 treatment for preterm labor. Serial blood samples were taken and measured total magnesium (T-Mg), ionized magnesium (I-Mg), total calcium (T-Ca), and ionized calcium (I-Ca) levels every one-week interval (1st, 2nd, 3rd). Results There was no significant difference in T-Mg and I-Mg levels during MgSO4 administration (P>0.05). There was no significant difference in T-Ca and I-Ca levels during MgSO4 administration (P>0.05). Compared before and after administration of MgSO4, T-Mg and I-Mg levels and T-Ca levels were changed allow statistically significant (P0.05). There was significant correlation between levels of I-Mg and T-Mg (I-Mg=0.395×T-Mg+0.144, P<0.01). Conclusion There were no significant differences in serum Mg and Ca levels during MgSO4 administration for preterm labor. Compared to the before and after administration of MgSO4, only I-Ca levels were not substantially changed. There are significant correlations between I-Mg and T-Mg levels during administration of MgSO4 and I-Mg level seemed to have more correlation with adverse effect than T-Mg. PMID:29372150

  4. Effect of elevated total CoA levels on metabolic pathways in cultured hepatocytes

    International Nuclear Information System (INIS)

    Steffen, C.A.; Smith, C.M.

    1987-01-01

    Livers from fasted rats have 30% higher total CoA levels than fed rats. To determine whether this increase of total CoA influences metabolism, the rates of gluconeogenesis, fatty acid oxidation and ketogenesis were measured in hepatocytes with cyanamide (CYM) or pantothenate (PA) deficient medium used to vary total CoA levels independently of hormonal status. Primary cultures of rat hepatocytes were incubated 14 hrs with Bt 2 cAMP, dexamethasone + theophylline in PA deficient medium or with CYM (500 μM) + PA, rinsed and preincubated 0.5 hr to remove the CYM. Hepatocytes treated with CYM had total CoA levels 10-24% higher than PA deficient cells and lower rates of glucose production from lactate + pyruvate (L/P) or from alanine (0.23 +/- 0.05 and 0.089 +/- 0.02 μm/mg protein, respectively in CYM treated cells compared to 0.33 +/- 0.06 and 0.130 +/- 0.006 in PA deficient cells). This decrease was not due to CYM per se, as the direct addition of CYM stimulated glucose production from L/P. CYM treated cells with 15-40% higher total CoA and 30% higher fatty acyl-CoA levels had the same rates of [ 14 C]-palmitate oxidation as PA deficient cells. However, rates of ketogenesis were lower in CYM treated cells (163 +/- 11 nm/mg compared to 217 +/- 14 nm/mg protein). These results suggest that physiological alterations of hepatic total CoA levels are not necessary for fasting rates of gluconeogenesis, fatty acid oxidation and ketogenesis

  5. Levels of plasma selenium and urinary total arsenic interact to affect the risk for prostate cancer.

    Science.gov (United States)

    Hsueh, Yu-Mei; Su, Chien-Tien; Shiue, Horng-Sheng; Chen, Wei-Jen; Pu, Yeong-Shiau; Lin, Ying-Chin; Tsai, Cheng-Shiuan; Huang, Chao-Yuan

    2017-09-01

    This study investigated whether plasma selenium levels modified the risk for prostate cancer (PC) related to arsenic exposure. We conducted a case-control study that included 318 PC patients and 318 age-matched, healthy control subjects. Urinary arsenic profiles were examined using HPLC-HG-AAS and plasma selenium levels were measured by ICP-MS. We found that plasma selenium levels displayed a significant dose-dependent inverse association with PC. The odds ratio (OR) and 95% confidence interval (CI) for PC was 0.07 (0.04-0.13) among participants with a plasma selenium level >28.06 μg/dL vs. ≤19.13 μg/dL. A multivariate analysis showed that participants with a urinary total arsenic concentration >29.28 μg/L had a significantly higher OR (1.75, 1.06-2.89) for PC than participants with ≤29.89 μg/L. The combined presence of a low plasma selenium level and a high urinary total arsenic concentration exponentially increased the OR for PC, and additively interacted with PSA at levels ≥20 ng/mL. This is the first epidemiological study to examine the combined effects of plasma selenium and urinary total arsenic levels on the OR for PC. Our data suggest a low plasma selenium level coupled with a high urinary total arsenic concentration creates a significant risk for aggressive PC. Copyright © 2017 Elsevier Ltd. All rights reserved.

  6. Evolution of extreme Total Water Levels along the northern coast of the Iberian Peninsula

    Directory of Open Access Journals (Sweden)

    D. F. Rasilla Álvarez

    2011-02-01

    Full Text Available This paper assesses the evolution of storminess along the northern coast of the Iberian Peninsula through the calculation of extreme (1% Total Water Levels (eTWL on both observed (tide gauge and buoy data and hindcasted (SIMAR-44 data. Those events were first identified and then characterized in terms of oceanographic parameters and atmospheric circulation features. Additionally, an analysis of the long-term trends in both types of data was performed. Most of the events correspond to a rough wave climate and moderate storm surges, linked to extratropical disturbances following a northern track. While local atmospheric conditions seem to be evolving towards lesser storminess, their impact has been balanced by the favorable exposure of the northern coast of the Iberian Peninsula to the increasing frequency and strength of distant disturbances crossing the North Atlantic. This evolution is also correctly reproduced by the simulated long-term evolution of the forcing component (meteorological sea level residuals and wave run up of the Total Water Level values calculated from the SIMAR 44 database, since sea level residuals have been experiencing a reduction while waves are arriving with longer periods. Finally, the addition of the rate of relative sea level trend to the temporal evolution of the atmospheric forcing component of the Total Water Level values is enough to simulate more frequent and persistent eTWL.

  7. Assessing adrenal insufficiency of corticosteroid secretion using free versus total cortisol levels in critical illness

    NARCIS (Netherlands)

    Molenaar, N.; Groeneveld, A.B.J.; Dijstelbloem, H.M.; de Jong, M.F.C.; Girbes, A.R.J.; Heijboer, A.C.; Beishuizen, A.

    2011-01-01

    Purpose: To study the value of free versus total cortisol levels in assessing relative adrenal insufficiency during critical illness-related corticosteroid insufficiency. Methods: A prospective study in a mixed intensive care unit from 2004 to 2007. We consecutively included 49 septic and 63

  8. Assessing adrenal insufficiency of corticosteroid secretion using free versus total cortisol levels in critical illness

    NARCIS (Netherlands)

    Molenaar, Nienke; Johan Groeneveld, A. B.; Dijstelbloem, Hilde M.; de Jong, Margriet F. C.; Girbes, Armand R. J.; Heijboer, Annemieke C.; Beishuizen, Albertus

    2011-01-01

    To study the value of free versus total cortisol levels in assessing relative adrenal insufficiency during critical illness-related corticosteroid insufficiency. A prospective study in a mixed intensive care unit from 2004 to 2007. We consecutively included 49 septic and 63 non-septic patients with

  9. Noise analysis of a digital radiography system

    International Nuclear Information System (INIS)

    Arnold, B.A.; Scheibe, P.O.

    1984-01-01

    The sources of noise in a digital video subtraction angiography system were identified and analyzed. Signal-to-noise ratios of digital radiography systems were measured using the digital image data recorded in the computer. The major sources of noise include quantum noise, TV camera electronic noise, quantization noise from the analog-to-digital converter, time jitter, structure noise in the image intensifier, and video recorder electronic noise. A new noise source was identified, which results from the interplay of fixed pattern noise and the lack of image registration. This type of noise may result from image-intensifier structure noise in combination with TV camera time jitter or recorder time jitter. A similar noise source is generated from the interplay of patient absorption inhomogeneities and patient motion or image re-registration. Signal-to-noise ratios were measured for a variety of experimental conditions using subtracted digital images. Image-intensifier structure noise was shown to be a dominant noise source in unsubtracted images at medium to high radiation exposure levels. A total-system signal-to-noise ratio (SNR) of 750:1 was measured for an input exposure of 1 mR/frame at the image intensifier input. The effect of scattered radiation on subtracted image SNR was found to be greater than previously reported. The detail SNR was found to vary approximately as one plus the scatter degradation factor. Quantization error noise with 8-bit image processors (signal-to-noise ratio of 890:1) was shown to be of increased importance after recent improvements in TV cameras. The results of the analysis are useful both in the design of future digital radiography systems and the selection of optimum clinical techniques

  10. Noise level arrangement in determined zones of homogenous development of green areas on the example of the spa park in Inowrocław

    Science.gov (United States)

    Sztubecka, Małgorzata; Skiba, Marta

    2016-11-01

    Noise measurements are usually carried out in developed areas as well as in the surroundings of traffic routes providing basis for actions in order to limit its influence on the neighboring areas. Noise measurements in park areas are rare due to belief that these areas are silent zones. Such attitude cannot be justified. This article aims to the assessment of noise appearing in determined subzones of the spa park in Inowrocław. From the research carried out it can be noticed that traffic noise does not have any important meaning for the acoustic climate of the park. It is the people who stay there who generate more noise. Comparative analysis proves the appearance and penetration of noise from the zones with greater level of noise to the ones with lower amount.

  11. Reduction of Air Pollution Levels Downwind of a Road with an Upwind Noise Barrier

    Science.gov (United States)

    We propose a dispersion model to characterize the impact of an upwind solid noise barrier next to a highway on air pollution concentrations downwind of the road. The model is based on data from wind tunnel experiments conducted by Heist et al. (2009). The model assumes that the...

  12. Noise levels in a neonatal intensive care unit in the Cape metropole

    African Journals Online (AJOL)

    2008-05-14

    May 14, 2008 ... stress for the neonate.2 Numerous published studies have ... The effects of noise on infants in the NICU have been well ... difficulties and information processing disorders at pre- and ... Division of Speech, Language and Hearing Therapy, Department of Interdisciplinary Health Sciences, Stellenbosch ...

  13. On the variances of generation-recombination noise in a three-level system

    NARCIS (Netherlands)

    Hooge, F.N.; Ren, L.

    1994-01-01

    A statistical treatment is given of the generation-recombination noise in a semiconductor with a conduction band and two traps X and Y. The system is described in terms of x and y, where x is half the harmonic mean of the numbers of occupied and empty traps X. A corresponding definition is given for

  14. Recent and long-term occupational noise exposure and salivary cortisol level

    DEFF Research Database (Denmark)

    Stokholm, Zara Ann; Hansen, Åse Marie; Grynderup, Matias Brødsgaard

    2014-01-01

    Environmental and occupational noise exposure have been related to increased risk of cardiovascular disease, hypothetically mediated by stress-activation of the hypothalamic-pituitary-adrenal (HPA) axis. The objective of this study was to investigate the relation between recent and long-term occu...

  15. Effects of buddleja officinalis total flavonoids on serum testosterone level of castrated male rats with xeroma

    Directory of Open Access Journals (Sweden)

    Wen-Juan Li

    2013-11-01

    Full Text Available AIM:To observe buddleja officinalis total flavonoids' effect on the basal tear secretion amount, tear film stability, lacrimal gland histomorphology and serum testosterone level of castrated male rat model with xeroma, to study the mechanism of rat xeroma caused by buddleja officinalis total flavones' anti-sex hormones disorders.MEATHODS: A total of 150 Wistar male rats of 1 month old, weighted about 200g, were randomly divided into 5 groups with 30 rats in each group with A representing normal group; B representing sham operation group; C representing surgery control group; D representing group treated with androgen; E representing group treated with buddleja officinalis total flavonoids. For the groups C, D, E, the bilateral testicle and epididymis were excised; For group B, scrota were incised without removal of the testicles, as the sham operation group; For group A, nothing was done. One week after modeling when the wound was to be healed, drug was given to each group. Respectively at the 1st month, 3rd, and 5th months after treatment, 10 rats were randomly selected in each group, to receive Schirmer I test, tear breakup time measurement. Blood serum testosterone levels were tested in the fifth month. RESUITS: For groups D and E, the Schirmer I test measurements were significantly higher than that of group C(PPPCONCLUSION: Decreased androgen levels can lead to xeroma, and removal of bilateral testes and epididymis can successfully establish the animal models of xeroma in rats caused by decreased androgen levels. Buddleja officinalis total flavonoids have androgenic effect, which produces the similar treatment effect of xeroma with testosterone propionate. Buddleja officinalis total flavonoids may become a new treatment for xeroma.

  16. Total circulating microparticle levels are increased in patients with deep infiltrating endometriosis.

    Science.gov (United States)

    Munrós, J; Martínez-Zamora, M A; Tàssies, D; Coloma, J L; Torrente, M A; Reverter, J C; Carmona, F; Balasch, J

    2017-02-01

    Are the levels of total circulating cell-derived microparticles (cMPs) and circulating tissue factor-containing microparticles (cMP-TF) increased in patients with endometriosis? The levels of total cMP, but not cMP-TF, were higher in patients with endometriosis, and these were attributed to higher levels in patients with deep infiltrating endometriosis (DIE). Previous studies have reported elevated levels of total cMP in inflammatory conditions as well as higher levels of other inflammatory biomarkers in endometriosis. Increased expression of tissue factor (a transmembrane receptor for Factor VII/VIIa) in eutopic and ectopic endometrium from patients with endometriosis has been described. There is no previous data regarding total cMP and cMP-TF levels in patients with endometriosis. A prospective case-control study including two groups of patients was carried out. The E group included 65 patients with surgically confirmed endometriosis (37 with DIE lesions) and the C group comprises 33 women without surgical findings of any form of endometriosis. Patients and controls were recruited during the same 10-month period. Controls were the next patient without endometriosis undergoing surgery, after including two patients with endometriosis. Venous blood samples for total cMP and cMP-TF determinations were obtained at the time of surgery, before anesthesia at a tertiary care center. To assess total cMP, an ELISA functional assay was used and cMP-TF activity in plasma was measured using an ELISA kit. Total cMP levels in plasma were higher in the E group compared with the C group (P < 0.0001). The subanalysis of endometriosis patients with DIE or with ovarian endometriomas without DIE showed that total cMP levels were higher in the DIE group (P = 0.001). There were no statistically significant differences in cMP-TF levels among the groups analyzed. This is a preliminary study in which the sample size was arbitrarily decided, albeit in keeping with previous studies analyzing

  17. Total mercury, cadmium and lead levels in main export fish of Sri Lanka.

    Science.gov (United States)

    Jinadasa, B K K K; Edirisinghe, E M R K B; Wickramasinghe, I

    2014-01-01

    Total mercury (Hg), cadmium (Cd) and lead (Pb) levels were determined in the muscle of four commercialised exported fish species Thunnus albacares (yellowfin tuna), Xiphias gladius (swordfish), Makaira indica (black marlin) and Lutjanus sp (red snapper) collected from the Indian Ocean, Sri Lanka, during July 2009-March 2010 and measured by atomic absorption spectrophotometry. Results show that swordfish (n = 176) contained the highest total Hg (0.90 ± 0.51 mg/kg) and Cd (0.09 ± 0.13 mg/kg) levels, whereas yellowfin tuna (n = 140) contained the highest Pb levels (0.11 ± 0.16 mg/kg). The lowest total Hg (0.16 ± 0.11 mg/kg), Cd (0.01 ± 0.01 mg/kg) and Pb (0.04 ± 0.04 mg/kg) levels were found in red snapper (n = 28). Black marlin (n = 24) contained moderate levels of total Hg (0.49 ± 0.37), Cd (0.02 ± 0.02) and Pb (0.05 ± 0.05). Even though there are some concerns during certain months of the year, this study demonstrates the safety of main export fish varieties in terms of total Hg, Cd and Pb.

  18. Hypogonadism and subnormal total testosterone levels in men with type 2 diabetes mellitus

    International Nuclear Information System (INIS)

    Ogbera, O.A.; Sonny, C.; Olufemi, F.; Wale, A.

    2011-01-01

    Objective: To determine the frequency of testosterone deficiency syndrome (TDS) in men with type 2 diabetes mellitus (DM). Study Design: A cross-sectional study. Place and Duration of Study: The Gbagada General Hospital, Gbagada Lagos, Nigeria, from December 2009 to May 2010. Methodology: A total of 203 men with type 2 DM aged 30-86 years were evaluated for TDS by a combination of positive ADAM (androgen deficiency in the ageing male) scores and subnormal total testosterone levels. Mild testosterone deficiency referred to total testosterone (TT) levels of 8-12 nmol/L with symptoms of hypogonadism and severe testosterone deficiency referred to TT levels < 8 nmol/L with or without hypogonadal symptoms. Results: Mild and severe TDS were present in 18.3% and 17% respectively of the study subjects. Commonly occurring clinical parameters of the TDS were erectile dysfunction and loss of libido, which were documented in 63% and 60% respectively in the study subjects. The majority of clinical features of the TDS were comparable in men with and without the TDS. Conclusion: About a third of men with type 2 DM had the TDS. The majority of the symptoms of hypogonadism are largely non-specific and their occurrence is comparable in men with and without low testosterone levels; thus, underscoring the need to have testosterone levels determined in men presenting with such symptoms. (author)

  19. Immunoglobulin levels in dogs after total-body irradiation and bone marrow transplantation

    International Nuclear Information System (INIS)

    Vriesendorp, H.M.; Halliwell, R.E.; Johnson, P.M.; Fey, T.A.; McDonough, C.M.

    1985-01-01

    The influence of total-body irradiation (TBI) and autologous or allogeneic bone marrow transplantation on serum immunoglobulin subclasses was determined in a dog model. Only IgG1 levels decreased after low-dose (+/- 4.5 Gy) TBI, but levels of all immunoglobulin classes fell after high-dose TBI (8.5 GyX1 or 2X6.0 Gy). After autologous bone marrow transplantation IgM levels were the first and IgE levels were the last to return to normal. After successful allogeneic bone marrow transplantation prolonged low IgM and IgE levels were found but IgA levels increased rapidly to over 150% of pretreatment values. A comparison of dogs with or without clinical signs or graft-versus-host disease (GVHD), revealed no differences in IgM levels. Dogs with GVHD had higher IgA but lower IgE levels. Dogs that rejected their allogeneic bone marrow cells showed significant early rises in IgE and IgA levels in comparison with dogs with GVHD. These results differ from the observations made on Ig levels in human bone marrow transplant patients. No significant differences in phytohemagglutinin stimulation tests were found between dogs with or without GVHD or dogs receiving an autologous transplant for the first four months after TBI and transplantation. An early primary or secondary involvement of humoral immunity in GVHD and graft rejection in dogs is postulated

  20. Noise properties of CT images reconstructed by use of constrained total-variation, data-discrepancy minimization

    DEFF Research Database (Denmark)

    Rose, Sean; Andersen, Martin S.; Sidky, Emil Y.

    2015-01-01

    Purpose: The authors develop and investigate iterative image reconstruction algorithms based on data-discrepancy minimization with a total-variation (TV) constraint. The various algorithms are derived with different data-discrepancy measures reflecting the maximum likelihood (ML) principle......: An incremental algorithm framework is developed for this purpose. The instances of the incremental algorithms are derived for solving optimization problems including a data fidelity objective function combined with a constraint on the image TV. For the data fidelity term the authors, compare application....... Simulations demonstrate the iterative algorithms and the resulting image statistical properties for low-dose CT data acquired with sparse projection view angle sampling. Of particular interest is to quantify improvement of image statistical properties by use of the ML data fidelity term. Methods...

  1. Tear ascorbic acid levels and the total antioxidant status in contact lens wearers: A pilot study

    Directory of Open Access Journals (Sweden)

    Venkata Sai

    2009-01-01

    Full Text Available Aims: The tear ascorbate owing to its high concentration, functions as an effective antioxidant against the oxidative damage of cornea. Contact lens wearers (CLW are prone to oxidative stress due to the lens-induced hypoxic conditions. A pilot study was done to compare the tear ascorbic acid level and the total antioxidant capacity give as in normal and CLW. Materials and Methods: In this study 21 CLW (Mean age 23 ± 3 years ; M-2, F-19, who were daily wear users, with duration of wear not more than four years, along with age-matched 28 controls (Mean age 28 ± 3 ; M-15, F-13 were recruited in the study for collection of reflex tears using Schirmer′s strip. Ascorbic acid in tears was determined using high-performance liquid chromatography (HPLC, total antioxidant capacity (TAC and total protein assay by spectrophotometric analysis. Results: CLW showed no significant change in the tear ascorbic acid levels (0.4 ± 0.26 mM compared to the control subjects (0.61 ± 0.59 mM. The amount of ascorbic acid in tears did not correlate with the TAC or the total protein of the tears. The mean TAC in CLW was 0.69 ± 0.16 mM, with a total protein of 1.35 ± 0.46 mg/ml while in controls it was 0.7 ± 0.18 mM and 1.21 ± 0.47 mg/ml respectively . Conclusions: Soft contact lens wear did not show any significant change in tear ascorbic acid, TAC and total protein levels compared to controls.

  2. Evaluation of noise pollution in urban traffic hubs—Noise maps and measurements

    International Nuclear Information System (INIS)

    Fiedler, Paulo Eduardo Kirrian; Zannin, Paulo Henrique Trombetta

    2015-01-01

    A study was made of some of the main traffic hubs in a Latin American metropolis, in order to determine the presence or absence of noise by means of noise measurements and acoustic mapping. To characterize noise in the evaluated road stretches, 232 measurements were taken at different points. The Predictor software package was used for the noise mapping calculations. Noise sensitive areas, e.g., hospitals, were identified in the evaluated road stretches. Noise maps were calculated for two hospitals, showing the current levels of noise that reach their facades. Hypothetical scenarios were simulated by making changes in the composition of traffic and total number of vehicles, and an assessment was made of the potential influence of these modifications in reducing the noise levels reaching the facades of the buildings in question. The simulations indicated that a 50% reduction in total traffic flow, or a 50% reduction in heavy vehicle traffic flow, would reduce the noise levels by about 3 dB(A). - Highlights: • Evaluation of noise pollution in urban traffic hubs • Street systems • Environmental noise impacts • Noise mapping

  3. Evaluation of noise pollution in urban traffic hubs—Noise maps and measurements

    Energy Technology Data Exchange (ETDEWEB)

    Fiedler, Paulo Eduardo Kirrian; Zannin, Paulo Henrique Trombetta, E-mail: paulo.zannin@pesquisador.cnpq.br

    2015-02-15

    A study was made of some of the main traffic hubs in a Latin American metropolis, in order to determine the presence or absence of noise by means of noise measurements and acoustic mapping. To characterize noise in the evaluated road stretches, 232 measurements were taken at different points. The Predictor software package was used for the noise mapping calculations. Noise sensitive areas, e.g., hospitals, were identified in the evaluated road stretches. Noise maps were calculated for two hospitals, showing the current levels of noise that reach their facades. Hypothetical scenarios were simulated by making changes in the composition of traffic and total number of vehicles, and an assessment was made of the potential influence of these modifications in reducing the noise levels reaching the facades of the buildings in question. The simulations indicated that a 50% reduction in total traffic flow, or a 50% reduction in heavy vehicle traffic flow, would reduce the noise levels by about 3 dB(A). - Highlights: • Evaluation of noise pollution in urban traffic hubs • Street systems • Environmental noise impacts • Noise mapping.

  4. Levels of total mercury in predatory fish sold in Canada in 2005

    OpenAIRE

    Dabeka, R.W.; McKenzie, A.D.; Forsyth, D.S.

    2011-01-01

    Total mercury was analysed in 188 samples of predatory fish purchased at the retail level in Canada in 2005. The average concentrations (ng g−1, range) were: sea bass 329 (38–1367), red snapper 148 (36–431), orange roughy 543 (279–974), fresh water trout 55 (20–430), grouper 360 (8–1060), black cod 284 (71–651), Arctic char 37 (28–54), king fish 440 (42–923), tilefish 601 (79–1164) and marlin 854 (125–2346). The Canadian standard for maximum total mercury allowed in the edible portions of fis...

  5. Comparison of Total Calcium Level during General and Spinal Anesthesia in Gynecologic Abdominal Surgeries

    Directory of Open Access Journals (Sweden)

    Katayoun Haryalchi

    2015-10-01

    Full Text Available  Background: Calcium (Ca+2 plays an important role in many biophysiological mechanisms .The present study was carried out to assess alterations in total serum calcium level before and after operations in consider to the type of anesthesia. Materials and Methods: This descriptive study was conducted on 74 women who candidate for gynecological abdominal operations during one year at Al-zahra maternity Hospital in Rasht, Iran. The patients underwent General Anesthesia (GA (N=37 or Spinal Anesthesia (SA (N=37 randomly. Blood samples (2 cc, were obtained an hour before the anesthesia and two hours after that. The blood samples had been sent to the laboratory for analyzing .Total serum calcium level, magnesium (Mg and albumin level were measured by photometric methods. Inferential statistic was analyzed with the Vilkson non-parametric and Pearson's correlation test. P-values less than 0.05 have been considered as significant different. Results: There was a significant trend to decrease in calcium levels after all gynecological abdominal operations, but there was a significant correlation between General anesthesia (GA and reduction of serum calcium level (p=0.026 . Therefore, General Anesthesia (GA is accompanied by more calcium reduction than Spinal Anesthesia (SA. Conclusion: Serum Calcium levels tend to decrease after all gynecological abdominal surgeries, but General Anesthesia (GA is accompanied by more calcium reduction than Spinal one. It needs to further specific studies, to illustrate association between different methods of anesthesia and Ca+2 changes.

  6. Elevation in Total Homocysteine Levels in Chinese Patients With Essential Hypertension Treated With Antihypertensive Benazepril.

    Science.gov (United States)

    Jiang, Shanqun; Pan, Mingluo; Wu, Suwen; Venners, Scott A; Zhong, Guisheng; Hsu, Yi-Hsiang; Weinstock, Justin; Wang, Binyan; Tang, Genfu; Liu, Dahai; Xu, Xiping

    2016-03-01

    To investigate the effect of benazepril on plasma homocysteine (Hcy) levels and to analyze the correlation between the methylenetetrahydrofolate reductase (MTHFR) C677T polymorphism and changes in Hcy levels in response to benazepril. A total of 231 patients with mild to moderate essential hypertension were enrolled, and benazepril was orally administered at a dose of 10 mg/d for 2 weeks. Plasma Hcy levels were measured by high-performance liquid chromatography at baseline and after 2 weeks of treatment. Genotyping of the MTHFR C677T polymorphism was performed by TaqMan probe technique. There was no significant change in Hcy level after benazepril treatment for 2 weeks (P = .97). However, stratified by baseline Hcy levels, the patients with baseline Hcy benazepril treatment. There were also no statistically significant interactions of gene and environment factors (ie, gene smoking and drinking) on the changes in Hcy levels after benazepril treatment. Benazepril may cause an increase in plasma Hcy levels among patients with hypertension with low baseline Hcy levels, while effect modification by MTHFR C677T genotypes on the changes in Hcy levels in response to benazepril was not significant among patients with essential hypertension. © The Author(s) 2015.

  7. Research on maximum level noise contaminated of remote reference magnetotelluric measurements using synthesized data

    Science.gov (United States)

    Gang, Zhang; Fansong, Meng; Jianzhong, Wang; Mingtao, Ding

    2018-02-01

    Determining magnetotelluric impedance precisely and accurately is fundamental to valid inversion and geological interpretation. This study aims to determine the minimum value of signal-to-noise ratio (SNR) which maintains the effectiveness of remote reference technique. Results of standard time series simulation, addition of different Gaussian noises to obtain the different SNR time series, and analysis of the intermediate data, such as polarization direction, correlation coefficient, and impedance tensor, show that when the SNR value is larger than 23.5743, the polarization direction disorder at morphology and a smooth and accurate sounding carve value can be obtained. At this condition, the correlation coefficient value of nearly complete segments between the base and remote station is larger than 0.9, and impedance tensor Zxy presents only one aggregation, which meet the natural magnetotelluric signal characteristic.

  8. Judgments of aircraft noise in a traffic noise background

    Science.gov (United States)

    Powell, C. A.; Rice, C. G.

    1975-01-01

    An investigation was conducted to determine subjective response to aircraft noise in different road traffic backgrounds. In addition, two laboratory techniques for presenting the aircraft noise with the background noise were evaluated. For one technique, the background noise was continuous over an entire test session; for the other, the background noise level was changed with each aircraft noise during a session. Subjective response to aircraft noise was found to decrease with increasing background noise level, for a range of typical indoor noise levels. Subjective response was found to be highly correlated with the Noise Pollution Level (NPL) measurement scale.

  9. Plasma oxidative stress and total thiol levels in Crimean-Congo hemorrhagic fever.

    Science.gov (United States)

    Karadag-Oncel, Eda; Erel, Ozcan; Ozsurekci, Yasemin; Caglayik, Dilek Yagci; Kaya, Ali; Gozel, Mustafa Gokhan; Icagasioglu, Fusun Dilara; Engin, Aynur; Korukluoglu, Gulay; Uyar, Yavuz; Elaldi, Nazif; Ceyhan, Mehmet

    2014-01-01

    In this study, we investigated the pro- and antioxidant status of patients with a pathogenesis of Crimean-Congo hemorrhagic fever (CCHF) in terms of their role in its pathogenesis. During the study period, 34 children and 41 adults were diagnosed with CCHF. The control group consisted of healthy age- and gender-matched children and adults. Serum levels of the total antioxidant capacity (TAC), total oxidant status (TOS), oxidative stress index (OSI), and plasma total thiol (TTL) were evaluated and compared between groups. The difference in mean TAC values between CCHF patients and healthy controls was not statistically significant (P > 0.05). Mean TOS, OSI, and TTL values were significantly lower in CCHF patients than in healthy controls (P 0.05). Our results suggest that TTL may play a more important role in CCHF pathogenesis than the other parameters investigated. The mean TOS and OSI values were higher in the control group than in CCHF patients.

  10. Maternal blood total oxypurines and erythrocyte 2,3-diphosphoglycerate levels during normal pregnancy.

    Science.gov (United States)

    Mizutani, S; Akiyama, H; Kurauchi, O; Taira, H; Yamada, R; Narita, O; Tomoda, Y

    1985-01-01

    The effects of pregnancy on the levels of maternal plasma total oxypurines (hypoxanthine, xanthine and uric acid) and erythrocyte 2,3-diphosphoglycerate (2,3-DPG) was investigated. With advancing gestation there was a slight increasing tendency in plasma total oxypurines as well as erythrocyte 2,3-DPG in pregnant women. When the ratio of 2,3-DPG to total oxypurines was calculated, the ratio was almost unchanged until week 34. After week 35, the ratio decreased to week 37; the ratios between week 37 and 40 had similar values to cord blood. The above data suggest that the changes of these metabolites in maternal peripheral blood may be indicative for hypoxia with fetoplacental tissue.

  11. Elevated levels of numerous cytokines in drainage fluid after primary total hip arthroplasty.

    Science.gov (United States)

    van der Heide, Huub J L; van der Kraan, Peter M; Rijnberg, Willard J; Buma, Pieter; Schreurs, B Willem

    2010-12-01

    As cytokines are involved in wound healing and other inflammatory processes, it could be valuable to measure their levels at the operative site. This study was conducted to investigate whether different cytokines are measurable in drainage fluid and, when measurable, whether we can find a difference in cytokine levels between one and six hours postoperatively. Samples from the drainage system in 30 consecutive patients undergoing primary total hip replacement were collected at one and six hours after closure of the wound. Levels of several cytokines were measured in the drainage fluids. A significant elevation of almost all cytokines was observed between the sample after one hour and six hours postoperatively. We found a strong correlation between the different pro-inflammatory cytokines. The IL-6 to IL-10 ratio were also raised, showing a pro-inflammatory predominance. Levels were much higher than those previously shown in serum.

  12. Total Jamur, Jenis Kapang dan Khamir Pellet Ayam Kampung Super dengan Penambahan Berbagai Level Pollard Berprobiotik

    Directory of Open Access Journals (Sweden)

    Muhammad Nurdianto

    2015-10-01

    Full Text Available (Total fungi, type of mold and yeasts in super native chicken pelleted feed with various level of probiotic pollard ABSTRACT. The research objective is assessing the effect of adding various level of probiotic pollard on total fungi, type of mold and  yeast. The material used in this research were fermented vegetables waste , molasses, distilled water, pollard,  super native chicken’s feed, physiological NaCl (0.85% NaCl and sabaroud glucose agar (SGA.  Research using  completely randomized design with 4 treatments and 4 replications. The treatment used were T0 = 100% feed + 0% probiotic pollard, T1 = 90% feed + 10% probiotic pollard, T2 = 80% feed + 20% probiotic pollard and T3 = 70% feed + 30% probiotic pollard. The observed parameters were total fungi, type of molds and yeast. The average of total fungi are 0  CFU; 0,55 x 107 CFU; 0,55 x 107 CFU and 0 CFU. Type of mold is Aspergillus niger and none yeast have grown. The conclusion is the addition of 10% and 20%  probiotic pollard to super native chicken’s pellet  yield mold type Aspergillus niger as much 0,55 x 107 CFU.

  13. Measuring total health inequality: adding individual variation to group-level differences

    Directory of Open Access Journals (Sweden)

    Gakidou Emmanuela

    2002-08-01

    Full Text Available Abstract Background Studies have revealed large variations in average health status across social, economic, and other groups. No study exists on the distribution of the risk of ill-health across individuals, either within groups or across all people in a society, and as such a crucial piece of total health inequality has been overlooked. Some of the reason for this neglect has been that the risk of death, which forms the basis for most measures, is impossible to observe directly and difficult to estimate. Methods We develop a measure of total health inequality – encompassing all inequalities among people in a society, including variation between and within groups – by adapting a beta-binomial regression model. We apply it to children under age two in 50 low- and middle-income countries. Our method has been adopted by the World Health Organization and is being implemented in surveys around the world; preliminary estimates have appeared in the World Health Report (2000. Results Countries with similar average child mortality differ considerably in total health inequality. Liberia and Mozambique have the largest inequalities in child survival, while Colombia, the Philippines and Kazakhstan have the lowest levels among the countries measured. Conclusions Total health inequality estimates should be routinely reported alongside average levels of health in populations and groups, as they reveal important policy-related information not otherwise knowable. This approach enables meaningful comparisons of inequality across countries and future analyses of the determinants of inequality.

  14. The Effect of Systemic Amantadine Sulfate on Malondialdehyde and Total Thiol Levels in Rat Corneas

    Directory of Open Access Journals (Sweden)

    Züleyha Yalniz-Akkaya

    2014-01-01

    Full Text Available Purpose: To evaluate the malondialdehyde (MDA and total thiol (sulfhydryl, SH levels in rat corneas after intraperitoneal injection of amantadine sulfate. Methods: A total of 12 Wistar albino rats were divided into two groups: control group (n = 6 and amantadine group (n = 6. Balanced salt solution (1 mL, 0.9% NaCl, twice/day was injected into rats in control group. Amantadine sulfate (2 mg/1 mL, twice/day was injected into rats in amantadine group. In each group, two rats were injected for 1 week, two received injections for 1 month, and two rats received injections for 3 months. The corneas were homogenized and MDA and SH levels were measured spectroflourometrically. Results: In control group, median MDA and SH levels were 2.37 (range, 0.92-3.60 and 25.35 (range, 6.30-54.0 nmol/mg, respectively. In amantadine group, median MDA and SH levels were 3.57 (range, 1.25-5.92 and 32.65 (range, 3.30-48.3 nmol/mg, respectively. The difference between this two groups regarding MDA (P = 0.14 and SH (P = 1.0 levels was statistically insignificant. Conclusion: Systemically administered amantadine sulfate seems not to cause MDA and SH imbalance in rat corneas.

  15. [Total homocysteine levels in children with diabetes type 1. Conditional factors].

    Science.gov (United States)

    Martínez Laborda, S; Salazar García-Blanco, M I; Rodríguez Rigual, M; Baldellou Vázquez, A

    2008-03-01

    To measure the plasma levels of total homocysteine (tHcy) in children with type I diabetes mellitus and their relationship with the control of the disease. We studied a total of 46 patients with ages between 4 and 19 years. The analyzed variables were: sex, age, puberty stage by Tanner, BMI, years of evolution of the illness, self-monitoring, associated diseases, tHcy, folic acid, vitamin B12, glycosylated haemoglobin (HbA1c), lipid profile and renal function. The mean tHcy was of 5.48 +/- 1,64 microm/l, similar to that in our control population. There was a positive correlation with tHcy when analyzing the puberty stage by the Tanner scale. The years of evolution of diabetes varied between 0.4 and 15, with a mean of 5.77 +/- 3.69, with no correlation with tHcy. The glycosylated haemoglobin mean was 7.35 %, with no correlation with tHcy. The levels of folic acid and vitamin B12 were similar to the control population. The lipid profile of our patients was normal, with no association with tHcy levels. There was no correlation between GFR and tHcy. A clinically correct control of children with diabetes mellitus type 1, appears to ensure a normal total homocysteinemia, with no significant differences with the healthy individuals of the same age and social environment.

  16. Total serum homocysteine levels do not identify cognitive dysfunction in multimorbid elderly patients.

    Science.gov (United States)

    Hengstermann, S; Laemmler, G; Hanemann, A; Schweter, A; Steinhagen-Thiessen, E; Lun, A; Schulz, R-J

    2009-02-01

    Total blood homocysteine (Hcys) and folate levels have been investigated in association with cognitive dysfunction in healthy but not in multimorbid elderly patients. We hypothesized that total serum Hcys is an adequate marker to identify multimorbid elderly patients with cognitive dysfunction assessed by the Short Cognitive Performance Test (SKT) and Mini-Mental State Examination (MMSE). Cross-sectional study. The study center was an acute geriatric hospital. A total of 189 multimorbid elderly patients were recruited. Cognitive dysfunction was determined according to the SKT and MMSE. Biochemical parameters (Hcys, folate, vitamin B12, hemoglobin), nutritional status (BMI, Mini Nutritional Assessment, nutritional intake), and activities of daily living were assessed. According to the SKT, 25.4% of patients showed no cerebral cognitive dysfunction, 21.2% had suspected incipient cognitive dysfunction, 12.7% showed mild cognitive dysfunction, 9.0% had moderate cognitive dysfunction, and 31.7% of patients were demented. The median plasma Hcys value was elevated by approximately 20% in multimorbid elderly patients, independent of cognitive dysfunction. Serum folate and vitamin B12 concentrations were within normal ranges. We did not find significant differences in nutritional status, activities of daily living, numbers of diseases or medications, or selected biochemical parameters between the SKT groups. Elevated serum Hcys levels with normal plasma folate and vitamin B12 concentrations were observed in multimorbid elderly patients. The plasma Hcys level did not appear to be an important biological risk factor for cognitive dysfunction in multimorbid geriatric patients.

  17. Total aflatoxins in complementary foods produced at community levels using locally available ingredients in Ethiopia.

    Science.gov (United States)

    Ayelign, Abebe; Woldegiorgis, Ashagrie Zewdu; Adish, Abdulaziz; De Saeger, Sarah

    2018-06-01

    This study was conducted to determine the occurrence and levels of total aflatoxins in complementary foods (CFs) and their ingredients. A total of 126 samples collected from 20 Districts from Amhara, Tigray, Oromia, and Southern Nations Nationalities and Peoples (SNNP) regions were analysed for levels of total aflatoxins using enzyme linked immunosorbent assay (ELISA). Aflatoxins were detected in 62 out of 66 pre-milling samples with mean range of 0.3-9.9 µg/kg. Aflatoxins were also detected in 19 out of 20 post-production CFs and in all of the one-month stored CFs at households and grain banks, with a mean range of 0.5-8.0, 3.6-11.3, and 0.2-12.4 µg/kg, respectively. Overall, 3 out of 126 samples exceeded the maximum limit (10 µg/kg). Although most aflatoxin levels were below the maximum limit and thus considered to be safe for consumption, more effort should be implemented to reduce contamination, as these CFs are intended for consumption by young children.

  18. Background noise levels measured in the NASA Lewis 9- by 15-foot low-speed wind tunnel

    Science.gov (United States)

    Woodward, Richard P.; Dittmar, James H.; Hall, David G.; Kee-Bowling, Bonnie

    1994-01-01

    The acoustic capability of the NASA Lewis 9 by 15 Foot Low Speed Wind Tunnel has been significantly improved by reducing the background noise levels measured by in-flow microphones. This was accomplished by incorporating streamlined microphone holders having a profile developed by researchers at the NASA Ames Research Center. These new holders were fabricated for fixed mounting on the tunnel wall and for an axially traversing microphone probe which was mounted to the tunnel floor. Measured in-flow noise levels in the tunnel test section were reduced by about 10 dB with the new microphone holders compared with those measured with the older, less refined microphone holders. Wake interference patterns between fixed wall microphones were measured and resulted in preferred placement patterns for these microphones to minimize these effects. Acoustic data from a model turbofan operating in the tunnel test section showed that results for the fixed and translating microphones were equivalent for common azimuthal angles, suggesting that the translating microphone probe, with its significantly greater angular resolution, is preferred for sideline noise measurements. Fixed microphones can provide a local check on the traversing microphone data quality, and record acoustic performance at other azimuthal angles.

  19. The association between low levels of lead in blood and occupational noise-induced hearing loss in steel workers

    International Nuclear Information System (INIS)

    Hwang, Yaw-Huei; Chiang, Han-Yueh; Yen-Jean, Mei-Chu; Wang, Jung-Der

    2009-01-01

    As the use of leaded gasoline has ceased in the last decade, background lead exposure has generally been reduced. The aim of this study was to examine the effect of low-level lead exposure on human hearing loss. This study was conducted in a steel plant and 412 workers were recruited from all over the plant. Personal information such as demographics and work history was obtained through a questionnaire. All subjects took part in an audiometric examination of hearing thresholds, for both ears, with air-conducted pure tones at frequencies of 500, 1000, 2000, 3000, 4000, 6000 and 8000 Hz. Subjects' blood samples were collected and analyzed for levels of manganese, copper, zinc, arsenic, cadmium and lead with inductive couple plasma-mass spectrometry. Meanwhile, noise levels in different working zones were determined using a sound level meter with A-weighting network. Only subjects with hearing loss difference of no more than 15 dB between both ears and had no congenital abnormalities were included in further data analysis. Lead was the only metal in blood found significantly correlated with hearing loss for most tested sound frequencies (p < 0.05 to p < 0.0001). After adjustment for age and noise level, the logistic regression model analysis indicated that elevated blood lead over 7 μg/dL was significantly associated with hearing loss at the sound frequencies of 3000 through 8000 Hz with odds ratios raging from 3.06 to 6.26 (p < 0.05 ∼ p < 0.005). We concluded that elevated blood lead at level below 10 μg/dL might enhance the noise-induced hearing loss. Future research needs to further explore the detailed mechanism.

  20. The association between low levels of lead in blood and occupational noise-induced hearing loss in steel workers

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, Yaw-Huei [Institute of Occupational Medicine and Industrial Hygiene, College of Public Health, National Taiwan University, Taipei, Taiwan, ROC Rm. 735, 17, Xu-Zhou Rd., Taipei, Taiwan, ROC (China); Department of Public Health, College of Public Health, National Taiwan University, Taipei, Taiwan, ROC Rm. 735, 17, Xu-Zhou Rd., Taipei, Taiwan, ROC (China); Chiang, Han-Yueh [Institute of Occupational Medicine and Industrial Hygiene, College of Public Health, National Taiwan University, Taipei, Taiwan, ROC Rm. 735, 17, Xu-Zhou Rd., Taipei, Taiwan, ROC (China); Yen-Jean, Mei-Chu [Division of Family Medicine, E-Da Hospital, Taiwan, ROC 1, E-Da Rd., Jiau-Shu Tsuen, Yan-Chau Shiang, Kaohsiung County, Taiwan, ROC (China); I-Shou University, Kaohsiung County, Taiwan, ROC 1, Sec. 1, Syuecheng Rd., Da-Shu Shiang, Kaohsiung County, Taiwan, ROC (China); Wang, Jung-Der, E-mail: jdwang@ntu.edu.tw [Institute of Occupational Medicine and Industrial Hygiene, College of Public Health, National Taiwan University, Taipei, Taiwan, ROC Rm. 735, 17, Xu-Zhou Rd., Taipei, Taiwan, ROC (China); Department of Public Health, College of Public Health, National Taiwan University, Taipei, Taiwan, ROC Rm. 735, 17, Xu-Zhou Rd., Taipei, Taiwan, ROC (China); Department of Internal Medicine, National Taiwan University Hospital and National Taiwan University College of Medicine, Taipei, Taiwan, ROC No. 1, Chang-Teh St., Taipei, Taiwan, ROC (China)

    2009-12-15

    As the use of leaded gasoline has ceased in the last decade, background lead exposure has generally been reduced. The aim of this study was to examine the effect of low-level lead exposure on human hearing loss. This study was conducted in a steel plant and 412 workers were recruited from all over the plant. Personal information such as demographics and work history was obtained through a questionnaire. All subjects took part in an audiometric examination of hearing thresholds, for both ears, with air-conducted pure tones at frequencies of 500, 1000, 2000, 3000, 4000, 6000 and 8000 Hz. Subjects' blood samples were collected and analyzed for levels of manganese, copper, zinc, arsenic, cadmium and lead with inductive couple plasma-mass spectrometry. Meanwhile, noise levels in different working zones were determined using a sound level meter with A-weighting network. Only subjects with hearing loss difference of no more than 15 dB between both ears and had no congenital abnormalities were included in further data analysis. Lead was the only metal in blood found significantly correlated with hearing loss for most tested sound frequencies (p < 0.05 to p < 0.0001). After adjustment for age and noise level, the logistic regression model analysis indicated that elevated blood lead over 7 {mu}g/dL was significantly associated with hearing loss at the sound frequencies of 3000 through 8000 Hz with odds ratios raging from 3.06 to 6.26 (p < 0.05 {approx} p < 0.005). We concluded that elevated blood lead at level below 10 {mu}g/dL might enhance the noise-induced hearing loss. Future research needs to further explore the detailed mechanism.

  1. The effect of audiovisual and binaural listening on the acceptable noise level (ANL): establishing an ANL conceptual model.

    Science.gov (United States)

    Wu, Yu-Hsiang; Stangl, Elizabeth; Pang, Carol; Zhang, Xuyang

    2014-02-01

    Little is known regarding the acoustic features of a stimulus used by listeners to determine the acceptable noise level (ANL). Features suggested by previous research include speech intelligibility (noise is unacceptable when it degrades speech intelligibility to a certain degree; the intelligibility hypothesis) and loudness (noise is unacceptable when the speech-to-noise loudness ratio is poorer than a certain level; the loudness hypothesis). The purpose of the study was to investigate if speech intelligibility or loudness is the criterion feature that determines ANL. To achieve this, test conditions were chosen so that the intelligibility and loudness hypotheses would predict different results. In Experiment 1, the effect of audiovisual (AV) and binaural listening on ANL was investigated; in Experiment 2, the effect of interaural correlation (ρ) on ANL was examined. A single-blinded, repeated-measures design was used. Thirty-two and twenty-five younger adults with normal hearing participated in Experiments 1 and 2, respectively. In Experiment 1, both ANL and speech recognition performance were measured using the AV version of the Connected Speech Test (CST) in three conditions: AV-binaural, auditory only (AO)-binaural, and AO-monaural. Lipreading skill was assessed using the Utley lipreading test. In Experiment 2, ANL and speech recognition performance were measured using the Hearing in Noise Test (HINT) in three binaural conditions, wherein the interaural correlation of noise was varied: ρ = 1 (N(o)S(o) [a listening condition wherein both speech and noise signals are identical across two ears]), -1 (NπS(o) [a listening condition wherein speech signals are identical across two ears whereas the noise signals of two ears are 180 degrees out of phase]), and 0 (N(u)S(o) [a listening condition wherein speech signals are identical across two ears whereas noise signals are uncorrelated across ears]). The results were compared to the predictions made based on the

  2. Total Testosterone Levels and the Effect of Sildenafil on Type 2 Diabetics with Erectile Dysfunction

    Directory of Open Access Journals (Sweden)

    Nabeel Najib Fadhil Hadeed

    2014-01-01

    Full Text Available Objectives: Hypotestosteronemia has been reported in approximately half of type 2 diabetic men in general. This study aims to assess serum total testosterone levels in type 2 diabetics with erectile dysfunction and to correlate the degree of improvement between sildenafil citrate and testosterone levels. Methods: A cross sectional and prospective comparative interventional study was conducted at the Diabetic Clinic of Assalam Teaching Hospital in Mosul, during the period from January 1, 2009 through to December 31, 2011. The study enrolled 120 type 2 diabetic males with erectile dysfunction who were analyzed with regard to age, duration of diabetes, duration and severity of erectile dysfunction, serum total testosteron levels and the degree of response to sildenafil citrate in terms of testosterone levels. The data were statistically analyzed using the independent two-sample Student t test, χ2 test and Pearson correlation test. A p-value of <0.05 was considered statistically significant. Results: Thirty six percent of type 2 diabetic males with erectile dysfunction were found to have low serum testosterone levels. The hypotestosteronemic and normotestosteronemic subgroups were not significantly different in terms of mean age, duration of diabetes, reduction of libido, and reduction in erectile function. The rate and the degree of improvement of erection by sildenafil in the normo-and-hypotestosteronemic respondents were not significantly different, but the degree of improvement by sildenafil was significantly correlated to testosterone levels among the hypotestosteronemic group. Conclusion: Hypotestosteronemia was found in 36% of type 2 diabetic males with erectile dysfunction. The degree of improvement of erectile dysfunction by sildenafil was directly proportional to the serum testosterone levels among the hypotestosteronemic group. Therapeutic supplement with testosterone preparation in the hypotestosteronemic diabetics with erectile

  3. The relationship between total testosterone levels and prostate cancer: a review of the continuing controversy.

    Science.gov (United States)

    Klap, Julia; Schmid, Marianne; Loughlin, Kevin R

    2015-02-01

    For many years it was believed that higher total testosterone contributed to prostate cancer and caused rapid cancer growth. International guidelines consider that adequate data are not available to determine whether there is additional risk of prostate cancer from testosterone replacement. Numerous studies with multiple designs and contradictory conclusions have investigated the relationship between total testosterone and prostate cancer development. To establish current knowledge in this field we reviewed the literature on total testosterone and the subsequent risk of prostate cancer as well as the safety of exogenous testosterone administration in patients with a history of prostate cancer. We searched the literature to identify articles from 1994 to 2014 related to the relationship between total testosterone and prostate cancer. Emphasis was given to prospective studies, series with observational data and randomized, controlled trials. Case reports were excluded. Articles on testosterone replacement safety were selected by patient population (under active surveillance or with a prostate cancer history). We organized our results according to the relationship between total testosterone and prostate cancer, including 1) the possible link between low total testosterone and prostate cancer, 2) the effect of high levels and 3) the absence of any link. Finally, we summarized studies of the risk of exogenous testosterone administration in patients already diagnosed with prostate cancer, treated or on active surveillance. We selected 45 articles of the relationship between total testosterone and prostate cancer, of which 18 and 17 showed a relationship to low and high total testosterone, respectively, and 10 showed no relation. Total testosterone was defined according to the definition in each article. Contradictory findings have been reported, largely due to the disparate methodologies used in many studies. Most studies did not adhere to professional society guidelines

  4. Serum total IgG and IgG4 levels in thyroid eye disease

    Directory of Open Access Journals (Sweden)

    Sy A

    2016-10-01

    Full Text Available Aileen Sy, Rona Z Silkiss Department of Ophthalmology, California Pacific Medical Center, San Francisco, CA, USA Purpose: To investigate the relationship between immunoglobulin G (IgG4-related disease (IgG4-RD and thyroid eye disease (TED with respect to IgG levels. Patients and methods: A retrospective review of total IgG, IgG subclass, and thyroid stimulating immunoglobulin (TSI levels in 24 patients with TED. Results: Five patients (20.8% demonstrated serum IgG4 levels consistent with IgG4-RD without any additional systemic disease. Total IgG and IgG subclass levels were found to be an inadequate proxy for TSI elevation. Conclusion: There may be a subtype of TED patients with elevated IgG4 in the absence of IgG4-RD systemic findings. Keywords: thyroid eye disease, IgG subclass, IgG4, Graves’ disease, Graves’ ophthalmopathy, IgG4-RD

  5. Decreased Hippocampal 5-HT and DA Levels Following Sub-Chronic Exposure to Noise Stress: Impairment in both Spatial and Recognition Memory in Male Rats.

    Science.gov (United States)

    Haider, Saida; Naqvi, Fizza; Batool, Zehra; Tabassum, Saiqa; Perveen, Tahira; Saleem, Sadia; Haleem, Darakhshan Jabeen

    2012-01-01

    Mankind is exposed to a number of stressors, and among them noise is one which can cause intense stress. High levels of background noise can severely impair one's ability to concentrate. The present study was aimed to investigate the effect of sub-chronic noise stress on cognitive behavior and hippocampal monoamine levels in male rats. The study was performed on 12 male Wistar rats, divided into two groups; the control and noise-exposed. The rats in the test group were subjected to noise stress, 4h daily for 15 days. Cognitive testing was performed by the Elevated Plus Maze test (EPM) and Novel Object Recognition test (NOR). HPLC-EC was used to determine hippocampal monoamine levels and their metabolites. The data obtained revealed a significant decrease in hippocampal serotonin (5-hydroxytryptamine; 5-HT) and dopamine (DA) levels, whereas turnover ratios of 5-HT and DA were significantly increased compared to the controls. Rats exposed to noise exhibited a significant decrement in spatial memory. A significantly decreased recognition index of rats exposed to noise as compared to the control was also observed in the NOR test. Results of the present findings suggest the role of decreased hippocampal 5-HT and DA in the impairment of cognitive function following noise exposure.

  6. On the variances of generation-recombination noise in a three-level system

    Science.gov (United States)

    Hooge, F. N.; Ren, L.

    1994-01-01

    A statistical treatment is given of the generation-recombination noise in a semiconductor with a conduction band and two traps X and Y. The system is described in terms of x and y, where x is half the harmonic mean of the numbers of occupied and empty traps X. A corresponding definition is given for y. The use of x and y makes the formalism very transparent. Simple, explicit relations are easily found, which can be further simplified by approximations depending on the ratios between N, x and y. We consider correlations and Burgess' theorem; time dependence and spectra are not discussed.

  7. Determination of total cyanide in Hanford Site high-level wastes

    International Nuclear Information System (INIS)

    Winters, W.I.; Pool, K.H.

    1994-05-01

    Nickel ferrocyanide compounds (Na 2-x Cs x NiFe (CN) 6 ) were produced in a scavenging process to remove 137 Cs from Hanford Site single-shell tank waste supernates. Methods for determining total cyanide in Hanford Site high-level wastes are needed for the evaluation of potential exothermic reactions between cyanide and oxidizers such as nitrate and for safe storage, processing, and management of the wastes in compliance with regulatory requirements. Hanford Site laboratory experience in determining cyanide in high-level wastes is summarized. Modifications were made to standard cyanide methods to permit improved handling of high-level waste samples and to eliminate interferences found in Hanford Site waste matrices. Interferences and associated procedure modifications caused by high nitrates/nitrite concentrations, insoluble nickel ferrocyanides, and organic complexants are described

  8. Determination of total cyanide in Hanford Site high-level wastes

    Energy Technology Data Exchange (ETDEWEB)

    Winters, W.I. [Westinghouse Hanford Co., Richland, WA (United States); Pool, K.H. [Pacific Northwest Lab., Richland, WA (United States)

    1994-05-01

    Nickel ferrocyanide compounds (Na{sub 2-x}Cs{sub x}NiFe (CN){sub 6}) were produced in a scavenging process to remove {sup 137}Cs from Hanford Site single-shell tank waste supernates. Methods for determining total cyanide in Hanford Site high-level wastes are needed for the evaluation of potential exothermic reactions between cyanide and oxidizers such as nitrate and for safe storage, processing, and management of the wastes in compliance with regulatory requirements. Hanford Site laboratory experience in determining cyanide in high-level wastes is summarized. Modifications were made to standard cyanide methods to permit improved handling of high-level waste samples and to eliminate interferences found in Hanford Site waste matrices. Interferences and associated procedure modifications caused by high nitrates/nitrite concentrations, insoluble nickel ferrocyanides, and organic complexants are described.

  9. Carvacrol attenuates serum levels of total protein, phospholipase A2 and histamine in asthmatic guinea pig

    Directory of Open Access Journals (Sweden)

    Mohammad Hossein Boskabady

    2016-11-01

    Full Text Available Objective: Pharmacological effects of carvacrol such as its anti-inflammatory activities have been shows. In this study the effects of carvacrol on serum levels of total protein (TP, phospholipase A2 (PLA2 and histamine in sensitized guinea pigs was evaluated. Materials and Methods: Sensitized guinea pigs were given drinking water alone (group S, drinking water containing three concentrations of carvacrol (40, 80 and 160 µg/ml or dexamethasone. Serum levels of TP, PLA2 and histamine were examined I all sensitized groups as well as a non-sensitized control group (n=6 for each group. Results: In sensitized animals, serum levels of TP, PLA2 and histamine were significantly increased compared to control animals (p

  10. The Effect of Exposure to High Noise Levels on the Performance and Rate of Error in Manual Activities.

    Science.gov (United States)

    Khajenasiri, Farahnaz; Zamanian, Alireza; Zamanian, Zahra

    2016-03-01

    Sound is among the significant environmental factors for people's health, and it has an important role in both physical and psychological injuries, and it also affects individuals' performance and productivity. The aim of this study was to determine the effect of exposure to high noise levels on the performance and rate of error in manual activities. This was an interventional study conducted on 50 students at Shiraz University of Medical Sciences (25 males and 25 females) in which each person was considered as its own control to assess the effect of noise on her or his performance at the sound levels of 70, 90, and 110 dB by using two factors of physical features and the creation of different conditions of sound source as well as applying the Two-Arm coordination Test. The data were analyzed using SPSS version 16. Repeated measurements were used to compare the length of performance as well as the errors measured in the test. Based on the results, we found a direct and significant association between the levels of sound and the length of performance. Moreover, the participant's performance was significantly different for different sound levels (at 110 dB as opposed to 70 and 90 dB, p < 0.05 and p < 0.001, respectively). This study found that a sound level of 110 dB had an important effect on the individuals' performances, i.e., the performances were decreased.

  11. Survey of total mercury and methylmercury levels in edible fish from the Adriatic Sea.

    Science.gov (United States)

    Storelli, M M; Giacominelli-Stuffler, R; Storelli, A; D'Addabbo, R; Palermo, C; Marcotrigiano, G O

    2003-12-01

    Total mercury and methylmercury concentrations were measured in the muscle tissue of different fish species from the Adriatic Sea to ascertain whether the concentrations exceeded the maximum level fixed by the European Commission. Large species-dependent variability was observed. The highest total mercury mean concentrations were in benthic (0.20-0.76 microg g(-1) wet wt) and demersal fish (0.22-0.73 microg g(-1) wet wt), while pelagic species showed the lowest levels (0.09-0.23 microg g(-1) wet wt). In 15% of frost fish, in 42% of skate and in 30% of angler fish samples total mercury concentrations exceeded the maximum level fixed by the European Commission (Hg = 1 microg g(-1) wet wt); for the species for which the maximum level was set to 0.5 microg g(-1) wet wt, concentrations exceeding the prescribed legal limit were observed in 6.4% of bokkem, in 6.6% of pandora, in 20% of megrin, in 12.5% of four-spotted megrim, in 16% of striped mullet, in 5.0% of forkbeard and in 5.3% of picarel samples. In all the different species, mercury was present almost completely in the methylated form, with mean percentages between 70 and 100%. Weekly intake was estimated and compared with the provisional tolerable weekly intake recommended by the FAO/WHO Expert Committee on Food Additives. A high exposure was associated with the consumption of only skates, frost fish and angler fish, thought the consumption of the other species, such as, megrim, four spotted megrim, red fish striped mullet and forkbeard, resulted in a weekly intake slightly below the established provisional tolerable weekly intake.

  12. Drinking Level, Drinking Pattern, and Twenty-Year Total Mortality Among Late-Life Drinkers.

    Science.gov (United States)

    Holahan, Charles J; Schutte, Kathleen K; Brennan, Penny L; Holahan, Carole K; Moos, Rudolf H

    2015-07-01

    Research on moderate drinking has focused on the average level of drinking. Recently, however, investigators have begun to consider the role of the pattern of drinking, particularly heavy episodic drinking, in mortality. The present study examined the combined roles of average drinking level (moderate vs. high) and drinking pattern (regular vs. heavy episodic) in 20-year total mortality among late-life drinkers. The sample comprised 1,121 adults ages 55-65 years. Alcohol consumption was assessed at baseline, and total mortality was indexed across 20 years. We used multiple logistic regression analyses controlling for a broad set of sociodemographic, behavioral, and health status covariates. Among individuals whose high level of drinking placed them at risk, a heavy episodic drinking pattern did not increase mortality odds compared with a regular drinking pattern. Conversely, among individuals who engage in a moderate level of drinking, prior findings showed that a heavy episodic drinking pattern did increase mortality risk compared with a regular drinking pattern. Correspondingly, a high compared with a moderate drinking level increased mortality risk among individuals maintaining a regular drinking pattern, but not among individuals engaging in a heavy episodic drinking pattern, whose pattern of consumption had already placed them at risk. Findings highlight that low-risk drinking requires that older adults drink low to moderate average levels of alcohol and avoid heavy episodic drinking. Heavy episodic drinking is frequent among late-middle-aged and older adults and needs to be addressed along with average consumption in understanding the health risks of late-life drinkers.

  13. Seminal plasma total antioxidant capacity and vitamin- C levels in asthenozoospermia: a case- control study

    Directory of Open Access Journals (Sweden)

    Ali Bidmeshkipour

    2010-03-01

    Full Text Available "n Normal 0 false false false EN-US X-NONE AR-SA MicrosoftInternetExplorer4 /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-priority:99; mso-style-qformat:yes; mso-style-parent:""; mso-padding-alt:0in 5.4pt 0in 5.4pt; mso-para-margin:0in; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:11.0pt; font-family:"Calibri","sans-serif"; mso-ascii-font-family:Calibri; mso-ascii-theme-font:minor-latin; mso-fareast-font-family:"Times New Roman"; mso-fareast-theme-font:minor-fareast; mso-hansi-font-family:Calibri; mso-hansi-theme-font:minor-latin; mso-bidi-font-family:Arial; mso-bidi-theme-font:minor-bidi;} Background: Defective sperm function is now recognized as one of the most important causes of male infertility. Seminal plasma possesses a rich source of different enzymatic and non-enzymatic antioxidants such as vitamin C (ascorbic acid that protect spermatozoa against oxidative stress as one of the mediators of infertility causing sperm dysfunction and low sperm quality. The aim of this study was investigation of seminal total antioxidant capacity and determination of vitamin C effects on sperm motility. "n"nMethods: We designed a case-control study with a total subject of 62 males. Sperm parameters were analyzed according to World Health Organization guidelines (WHO, 1999. Total antioxidant capacity and vitamin C level of seminal plasma were measured in the 32 normozoospermic as the control group and 32 asthenospermic men as the case group using FRAP (Ferric Reducing of Antioxidants Powers and RP-HPLC (Reverse Phase High Performance Liquid Chromatography methods, respectively. "n"nResults: Our results indicated that total antioxidant capacity levels in the seminal plasma of asthenospermic men were significantly lower than healthy men (p=0.002. In addition, we found a positive correlation between reduced total

  14. Serum immunoglobulin levels in humans exposed to therapeutic total-body gamma irradiation

    International Nuclear Information System (INIS)

    Chaskes, S.; Kingdon, G.C.; Balish, E.

    1975-01-01

    Reduced serum immunoglobulin (IgA, IgG, IgM) levels developed in the majority of 27 patients with hematologic disorders after treatment with 100 to 350 R total-body gamma-ray exposures at a dose rate of either 1.5 R/min to 1.5 R/hr. A reduction in IgA of 20 percent or more was found in 66 percent of the cases, while 56 percent showed an IgM decrease, and 49 percent an IgG decrease of 20 percent. The severity of immunoglobulin depression was influenced by the total radiation dose and the patient's primary disease. The occurrence of IgG and IgM depression was greater when the radiation was given at 1.5 R/hr than when the dose rate was 1.5 R/min. Substantial but incomplete recovery toward preirradiation immunoglobulin levels was found for most patients by 7 wk after total-body irradiation (TBI). (U.S.)

  15. Low-level waste disposal performance assessments - Total source-term analysis

    Energy Technology Data Exchange (ETDEWEB)

    Wilhite, E.L.

    1995-12-31

    Disposal of low-level radioactive waste at Department of Energy (DOE) facilities is regulated by DOE. DOE Order 5820.2A establishes policies, guidelines, and minimum requirements for managing radioactive waste. Requirements for disposal of low-level waste emplaced after September 1988 include providing reasonable assurance of meeting stated performance objectives by completing a radiological performance assessment. Recently, the Defense Nuclear Facilities Safety Board issued Recommendation 94-2, {open_quotes}Conformance with Safety Standards at Department of Energy Low-Level Nuclear Waste and Disposal Sites.{close_quotes} One of the elements of the recommendation is that low-level waste performance assessments do not include the entire source term because low-level waste emplaced prior to September 1988, as well as other DOE sources of radioactivity in the ground, are excluded. DOE has developed and issued guidance for preliminary assessments of the impact of including the total source term in performance assessments. This paper will present issues resulting from the inclusion of all DOE sources of radioactivity in performance assessments of low-level waste disposal facilities.

  16. The impact of a noise reduction quality improvement project upon sound levels in the open-unit-design neonatal intensive care unit.

    Science.gov (United States)

    Liu, W F

    2010-07-01

    To decrease measured sound levels in the neonatal intensive care unit through implementation of human factor and minor design modification strategies. Prospective time series. Two open-unit-design neonatal centers. Implementation of a coordinated program of noise reduction strategies did not result in any measurable improvement in levels of loudness or quiet. Two centers, using primarily human behavior noise reduction strategies, were unable to demonstrate measurable improvements in sound levels within the occupied open-unit-design neonatal intensive care unit.

  17. Problems of noise modeling in the presence of total current branching in high electron mobility transistor and field-effect transistor channels

    International Nuclear Information System (INIS)

    Shiktorov, P; Starikov, E; Gružinskis, V; Varani, L; Sabatini, G; Marinchio, H; Reggiani, L

    2009-01-01

    In the framework of analytical and hydrodynamic models for the description of carrier transport and noise in high electron mobility transistor/field-effect transistor channels the main features of the intrinsic noise of transistors are investigated under continuous branching of the current between channel and gate. It is shown that the current-noise and voltage-noise spectra at the transistor terminals contain an excess noise related to thermal excitation of plasma wave modes in the dielectric layer between the channel and gate. It is found that the set of modes of excited plasma waves can be governed by the external embedding circuits, thus violating a universal description of noise in terms of Norton and Thevenin noise generators

  18. Estimation of a noise level using coarse-grained entropy of experimental time series of internal pressure in a combustion engine

    International Nuclear Information System (INIS)

    Litak, Grzegorz; Taccani, Rodolfo; Radu, Robert; Urbanowicz, Krzysztof; HoIyst, Janusz A.; Wendeker, MirosIaw; Giadrossi, Alessandro

    2005-01-01

    We report our results on non-periodic experimental time series of pressure in a single cylinder spark ignition engine. The experiments were performed for different levels of loading. We estimate the noise level in internal pressure calculating the coarse-grained entropy from variations of maximal pressures in successive cycles. The results show that the dynamics of the combustion is a non-linear multidimensional process mediated by noise. Our results show that so defined level of noise in internal pressure is not monotonous function of loading

  19. Ethanol affects acylated and total ghrelin levels in peripheral blood of alcohol-dependent rats.

    Science.gov (United States)

    Szulc, Michal; Mikolajczak, Przemyslaw L; Geppert, Bogna; Wachowiak, Roman; Dyr, Wanda; Bobkiewicz-Kozlowska, Teresa

    2013-07-01

    There is a hypothesis that ghrelin could take part in the central effects of alcohol as well as function as a peripheral indicator of the changes which occur during long-term alcohol consumption. The aim of this study was to determine a correlation between alcohol concentration and acylated and total form of ghrelin after a single administration of alcohol (intraperitoneal, i.p.) (experiment 1) and prolonged ethanol consumption (experiment 2). The study was performed using Wistar alcohol preferring (PR) and non-preferring (NP) rats and rats from inbred line (Warsaw High Preferring, WHP; Warsaw Low Preferring, WLP). It was found that ghrelin in ethanol-naive WHP animals showed a significantly lower level when compared with the ethanol-naive WLP or Wistar rats. After acute ethanol administration in doses of 1.0; 2.0 and 4.0 g/kg, i.p., the simple (WHP) or inverse (WLP and Wistar) relationship between alcohol concentration and both form of ghrelin levels in plasma were found. Chronic alcohol intake in all groups of rats led to decrease of acylated ghrelin concentration. PR and WHP rats, after chronic alcohol drinking, had lower levels of both form of ghrelin in comparison with NP and WLP rats, respectively, and the observed differences in ghrelin levels were in inverse relationship with their alcohol intake. In conclusion, it is suggested that there is a strong relationship between alcohol administration or intake, ethanol concentration in blood and both active and total ghrelin level in the experimental animals, and that ghrelin plasma concentration can be a marker of alcohol drinking predisposition. © 2013 The Authors, Addiction Biology © 2013 Society for the Study of Addiction.

  20. Millennial total sea-level commitments projected with the Earth system model of intermediate complexity LOVECLIM

    International Nuclear Information System (INIS)

    Goelzer, H; Huybrechts, P; Raper, S C B; Loutre, M-F; Goosse, H; Fichefet, T

    2012-01-01

    Sea-level is expected to rise for a long time to come, even after stabilization of human-induced climatic warming. Here we use simulations with the Earth system model of intermediate complexity LOVECLIM to project sea-level changes over the third millennium forced with atmospheric greenhouse gas concentrations that stabilize by either 2000 or 2100 AD. The model includes 3D thermomechanical models of the Greenland and Antarctic ice sheets coupled to an atmosphere and an ocean model, a global glacier melt algorithm to account for the response of mountain glaciers and ice caps, and a procedure for assessing oceanic thermal expansion from oceanic heat uptake. Four climate change scenarios are considered to determine sea-level commitments. These assume a 21st century increase in greenhouse gases according to SRES scenarios B1, A1B and A2 with a stabilization of the atmospheric composition after the year 2100. One additional scenario assumes 1000 years of constant atmospheric composition from the year 2000 onwards. For our preferred model version, we find an already committed total sea-level rise of 1.1 m by 3000 AD. In experiments with greenhouse gas concentration stabilization at 2100 AD, the total sea-level rise ranges between 2.1 m (B1), 4.1 m (A1B) and 6.8 m (A2). In all scenarios, more than half of this amount arises from the Greenland ice sheet, thermal expansion is the second largest contributor, and the contribution of glaciers and ice caps is small as it is limited by the available ice volume of maximally 25 cm of sea-level equivalent. Additionally, we analysed the sensitivity of the sea-level contributions from an ensemble of nine different model versions that cover a large range of climate sensitivity realized by model parameter variations of the atmosphere–ocean model. Selected temperature indices are found to be good predictors for sea-level contributions from the different components of land ice and oceanic thermal expansion after 1000 years. (letter)

  1. The relationship between debt levels and total shareholder return of JSE-listed platinum companies

    Directory of Open Access Journals (Sweden)

    Sandra Jooste

    2016-02-01

    Full Text Available The purpose of this study is to investigate empirically whether there is a positive correlation between debt levels and total shareholder return (TSR of platinum JSE-listed companies. The study field comprised annual analyses for 12 companies listed under the Platinum and Precious Metals sector on the JSE Ltd for the 14-year period 2000 to 2013. The results of the study were inconclusive as a statistically significant positive correlation between changes in debt levels and changes in TSR could only be found in two of these years. The core audience of the study will be the management of South African platinum companies considering changes in their capital structure, and investors considering investment in a listed platinum company. The contribution of the study is therefore to add to the body of literature on capital structure decisions from a South African platinum mine context

  2. Do Cost Functions for Tracking Error Generalize across Tasks with Different Noise Levels?

    Directory of Open Access Journals (Sweden)

    Jonathon Sensinger

    Full Text Available Control of human-machine interfaces are well modeled by computational control models, which take into account the behavioral decisions people make in estimating task dynamics and state for a given control law. This control law is optimized according to a cost function, which for the sake of mathematical tractability is typically represented as a series of quadratic terms. Recent studies have found that people actually use cost functions for reaching tasks that are slightly different than a quadratic function, but it is unclear which of several cost functions best explain human behavior and if these cost functions generalize across tasks of similar nature but different scale. In this study, we used an inverse-decision-theory technique to reconstruct the cost function from empirical data collected on 24 able-bodied subjects controlling a myoelectric interface. Compared with previous studies, this experimental paradigm involved a different control source (myoelectric control, which has inherently large multiplicative noise, a different control interface (control signal was mapped to cursor velocity, and a different task (the tracking position dynamically moved on the screen throughout each trial. Several cost functions, including a linear-quadratic; an inverted Gaussian, and a power function, accurately described the behavior of subjects throughout this experiment better than a quadratic cost function or other explored candidate cost functions (p<0.05. Importantly, despite the differences in the experimental paradigm and a substantially larger scale of error, we found only one candidate cost function whose parameter was consistent with the previous studies: a power function (cost ∝ errorα with a parameter value of α = 1.69 (1.53-1.78 interquartile range. This result suggests that a power-function is a representative function of user's error cost over a range of noise amplitudes for pointing and tracking tasks.

  3. Approaches to decrease the level of parasitic noise over vibroacoustic channel in terms of configuring information security tools

    Science.gov (United States)

    Ivanov, A. V.; Reva, I. L.; Babin, A. A.

    2018-04-01

    The article deals with influence of various ways to place vibration transmitters on efficiency of rooms safety for negotiations. Standing for remote vibration listening of window glass, electro-optical channel, the most typical technical channel of information leakage, was investigated. The modern system “Sonata-AB” of 4B model is used as an active protection tool. Factors influencing on security tools configuration efficiency have been determined. The results allow utilizer to reduce masking interference level as well as parasitic noise with keeping properties of room safety.

  4. Variations in voice level and fundamental frequency with changing background noise level and talker-to-listener distance while wearing hearing protectors: A pilot study.

    Science.gov (United States)

    Bouserhal, Rachel E; Macdonald, Ewen N; Falk, Tiago H; Voix, Jérémie

    2016-01-01

    Speech production in noise with varying talker-to-listener distance has been well studied for the open ear condition. However, occluding the ear canal can affect the auditory feedback and cause deviations from the models presented for the open-ear condition. Communication is a main concern for people wearing hearing protection devices (HPD). Although practical, radio communication is cumbersome, as it does not distinguish designated receivers. A smarter radio communication protocol must be developed to alleviate this problem. Thus, it is necessary to model speech production in noise while wearing HPDs. Such a model opens the door to radio communication systems that distinguish receivers and offer more efficient communication between persons wearing HPDs. This paper presents the results of a pilot study aimed to investigate the effects of occluding the ear on changes in voice level and fundamental frequency in noise and with varying talker-to-listener distance. Twelve participants with a mean age of 28 participated in this study. Compared to existing data, results show a trend similar to the open ear condition with the exception of the occluded quiet condition. This implies that a model can be developed to better understand speech production for the occluded ear.

  5. Industry-level total-factor energy efficiency in developed countries: A Japan-centered analysis

    International Nuclear Information System (INIS)

    Honma, Satoshi; Hu, Jin-Li

    2014-01-01

    Highlights: • This study compares Japan with other developed countries for energy efficiency at the industry level. • We compute the total-factor energy efficiency (TFEE) for industries in 14 developed countries in 1995–2005. • Energy conservation can be further optimized in Japan’s industry sector. • Japan experienced a slight decrease in the weighted TFEE from 0.986 in 1995 to 0.927 in 2005. • Japan should adapt energy conservation technologies from the primary benchmark countries: Germany, UK, and USA. - Abstract: Japan’s energy security is more vulnerable today than it was before the Fukushima Daiichi nuclear power plant accident in March 2011. To alleviate its energy vulnerability, Japan has no choice but to improve energy efficiency. To aid in this improvement, this study compares Japan’s energy efficiency at the industry level with that of other developed countries. We compute the total-factor energy efficiency (TFEE) of industries in 14 developed countries for 1995–2005 using data envelopment analysis. We use four inputs: labor, capital stock, energy, and non-energy intermediate inputs. Value added is the only relevant output. Results indicate that Japan can further optimize energy conservation because it experienced only a marginal decrease in the weighted TFEE, from 0.986 in 1995 to 0.927 in 2005. To improve inefficient industries, Japan should adapt energy conservation technologies from benchmark countries such as Germany, the United Kingdom, and the United States

  6. Transrectal ultrasound in detecting prostate cancer compared with serum total prostate-specific antigen levels

    International Nuclear Information System (INIS)

    Tamsel, S.; Killi, R.; Demirpolat, G.; Hekimgil, M.; Soydan, S.; Altay, B.

    2008-01-01

    We carried out a retrospective study to review the efficiency of grey-scale transrectal ultrasonography (TRUS) in detecting prostate cancer compared with the data in recent published work, including alternative imaging methods of the prostate gland. Our study group consisted of 830 patients who underwent TRUS-guided biopsy of the prostate between May 2000 and June 2004. The relation between abnormal TRUS findings and serum total prostate-specific antigen (tPSA) levels was evaluated in patients with prostate cancer who were divided into three different groups according to serum tPSA levels. Group I included patients with tPSA levels of 4-9.9 ng/mL, group II included tPSA levels of 10-19.9 ng/mL and group III included patients with tPSA levels of 20 ng/mL or more. In general, TRUS detected 185 (64%) of 291 cancers with a specificity of 89%, a PPV of 76% and an accuracy of 80%. TRUS findings enabled the correct identification of 22 (56%) of the 39 cancers in group I, 28 (30%) of the 93 cancers in group II and 135 (85%) of the 159 cancers in group III. In conclusion, TRUS alone has a limited potential to identify prostate cancer, especially in patients with tPSA levels lower than 20 ng/mL. Therefore, increased numbers of systematically placed biopsy cores must be taken or alternative imaging methods are required to direct TRUS-guided biopsy for improving prostate cancer detection.

  7. [Levels of total lipids, cholesterol and progesterone during estrus synchronization and pregnancy in sheep].

    Science.gov (United States)

    Krajnicáková, M; Bekeová, E; Hendrichovský, V; Maracek, I

    1993-01-01

    Our investigations were concerned with dynamic changes in total lipids (CL), cholesterol (CHOL) and progesterone (P4) in blood serum of sheep in the period of oestrus synchronization treatment and during mating and gravidity. Our experiment was carried out using 10 animals housed under the conditions of productive rearing. Blood samples were taken from v. jugularis on day of swab application (day 0) and on days 3 and 7 of the action of Agelin vaginal swabs, on day of insemination, and on days 7, 14, 17 and in the 2nd, 3rd and 4th month of gravidity. Blood serum was used to determine total lipids and cholesterol by means of Bio-Lachema tests, and P4 concentrations employing RIA-test-Prog kits (URVJT, Kosice). A statistically significant decrease in concentrations of total lipids (Fig. 1, Tab. I) in sheep blood serum was recorded on day of insemination (P < 0.05) compared to day 0, with the value 1.59 +/- 0.31 g/l of serum, and in the 3rd month of gravidity (P < 0.01), at concentrations 1.36 +/- 0.38 g/l of serum. The determined decrease in their values in the mentioned period can be modulated by the mutually changing ratio of steroid hormones or by inhibition of synthesis of lipoproteins responsible for changes in total plasma lipids. Changes in cholesterol concentrations (Fig. 2, Tab. I) during the introduction of swabs were insignificant and ranged from 1.60 +/- 0.42 to 1.73 +/- 0.33 mmol/l of serum. An insignificant increase in cholesterol concentrations (P < 0.05), with its highest levels 1.98 +/- 0.43 mmol/l of serum, was recorded in the 3rd month of gravidity.(ABSTRACT TRUNCATED AT 250 WORDS)

  8. Application of the kurtosis statistic to the evaluation of the risk of hearing loss in workers exposed to high-level complex noise.

    Science.gov (United States)

    Zhao, Yi-Ming; Qiu, Wei; Zeng, Lin; Chen, Shan-Song; Cheng, Xiao-Ru; Davis, Robert I; Hamernik, Roger P

    2010-08-01

    Develop dose-response relations for two groups of industrial workers exposed to Gaussian or non-Gaussian (complex) types of continuous noises and to investigate what role, if any, the kurtosis statistic can play in the evaluation of industrial noise-induced hearing loss (NIHL). Audiometric and noise exposure data were acquired on a population (N = 195) of screened workers from a textile manufacturing plant and a metal fabrication facility located in Henan province of China. Thirty-two of the subjects were exposed to non-Gaussian (non-G) noise and 163 were exposed to a Gaussian (G) continuous noise. Each subject was given a general physical and an otologic examination. Hearing threshold levels (0.5-8.0 kHz) were age adjusted (ISI-1999) and the prevalence of NIHL at 3, 4, or 6 kHz was determined. The kurtosis metric, which is sensitive to the peak and temporal characteristics of a noise, was introduced into the calculation of the cumulative noise exposure metric. Using the prevalence of hearing loss and the cumulative noise exposure metric, a dose-response relation for the G and non-G noise-exposed groups was constructed. An analysis of the noise environments in the two plants showed that the noise exposures in the textile plant were of a Gaussian type with an Leq(A)8hr that varied from 96 to 105 dB whereas the exposures in the metal fabrication facility with an Leq(A)8hr = 95 dB were of a non-G type containing high levels (up to 125 dB peak SPL) of impact noise. The kurtosis statistic was used to quantify the deviation of the non-G noise environment from the Gaussian. The dose-response relation for the non-G noise-exposed subjects showed a higher prevalence of hearing loss for a comparable cumulative noise exposure than did the G noise-exposed subjects. By introducing the kurtosis variable into the temporal component of the cumulative noise exposure calculation, the two dose-response curves could be made to overlap, essentially yielding an equivalent noise

  9. Effects of acoustic treatment on the interior noise levels of a twin-engine propeller aircraft - Experimental flight results and theoretical predictions

    Science.gov (United States)

    Beyer, T. B.; Powell, C. A.; Daniels, E. F.; Pope, L. D.

    1984-01-01

    In-flight noise level measurements were made within two cabin configurations of a general aviation business aircraft. The Fairchild Merlin IVC twin-engine aircraft was tested with bare walls and fiberglass insulation and in an executive trim configuration. Narrow-band and octave format data were subjected to analyses which permitted identification of the blade passage harmonics (BPH). Cabin noise level reductions (insertion losses) due to added insulation varied with position in the cabin, the BPH number, cabin pressure, and engine torque. The measurements were closely predicted using the propeller aircraft interior noise (PAIN) mode.

  10. Total serum bilirubin levels and sensorineural hearing loss in the US adolescents: NHANES 2007-2010.

    Science.gov (United States)

    Zhou, Guoli; Fu, Wenjiang

    2018-02-01

    We aimed to investigate whether current levels of total serum bilirubin are associated with different subtypes of sensorineural hearing loss (SNHL) in adolescents. A set of cross-sectional data from the National Health and Nutrition Examination Survey (NHANES) (2007-2010) was used. A subset of 1404 adolescents was sampled for measurements of total serum bilirubin, tympanometry, and average pure tone threshold at low-frequencies (LPTA: 500, 1000, 2000 Hz) or high-frequencies (HPTA: 3000, 4000, 6000, and 8000 Hz). SNHL was defined as the hearing loss that had type A tympanograms with a peak admittance of 0.3 ml or greater. Associations between serum bilirubin (square-root transformed) and different subtypes of SNHL were evaluated using binary or multinomial logistic regression models with 4-year sampling weights. The bootstrap method was used for estimation of variance and 10-fold cross-validation for assessment of overfitting issue. Total serum bilirubin levels were found to be associated with any high-frequency (HPTA>15 dB in at least one ear, adjusted odds-ratio (OR a )(bootstrap 95% confidence interval) = 3.29(1.31-8.19), p = 0.011), but not with any low-frequency (LPTA>15 dB in at least one ear), SNHL in the US adolescents. Furthermore, high-frequency SNHL with HPTA>15 dB in both ears (bilateral) or HPTA≥25 dB in at least one ear, compared to that with HPTA>15 dB in one ear only (unilateral) or HPTA = 15-25 dB in at least one ear, had a stronger association with total serum bilirubin levels (OR a  = 5.37(1.27-22.65), p = 0.022 for bilateral; OR a  = 2.64(0.84-8.25), p = 0.094 for unilateral; OR a  = 5.00(0.95-26.58), p = 0.058 for HPTA≥25 dB in at least one ear; as well as OR a  = 3.06(1.15-8.25), p = 0.025 for HPTA = 15-25 dB in at least one ear). No severe overfitting problems were found. Our findings suggest that current levels of total serum bilirubin may be informative in predicting and/or targeting high-frequency SNHL

  11. The Influence of Geography and Geology on Seismic Background Noise Levels Across the United States as Revealed by the Transportable Array

    Science.gov (United States)

    Anthony, R. E.; Ringler, A. T.; Holland, A. A.; Wilson, D. C.

    2017-12-01

    The EarthScope USArray Transportable Array (TA) has now covered the US with 3-component broadband seismometers at approximately 70 km station spacing and deployment durations of approximately 2 years. This unprecedented coverage, combined with high-quality and near homogenous installation techniques, offers a novel dataset in which to characterize spatially varying levels of background seismic noise across the United States. We present background noise maps in period bands of interest to earthquake and imaging seismology across the US (lower 48 states and Alaska). Early results from the contiguous 48 states demonstrate that ambient noise levels within the body wave period band (1-5 s) vary by > 20 dB (rel. 1 (m/s2)2/Hz) with the highest noise levels occurring at stations located within sedimentary basins and lowest within the mountain ranges of the Western US. Additionally, stations around the Great Lakes observe heightened noise levels in this band beyond the aforementioned basin amplification. We attribute this observation to local swell activity in the Great Lakes generating short-period microseism signals. This suggests that lake-generated microseisms may be a significant source of noise for Alaskan deployments situated in close proximity to lakes to facilitate float plane access. We further investigate how basin amplification and short-period lake microseism signals may noticeably impact detection and signal-to-noise of teleseismic body wave signals during certain time periods. At longer-periods (> 20 s), we generally observe larger noise levels on the horizontal components of stations situated in basins or on soft sediment, likely caused by locally induced tilt of the sensor. We will present similar analysis from the initial Alaska TA dataset to quantitatively assess how utilization of posthole sensors affects signal-to-noise for the long-period horizontal wavefield.

  12. Combined effect of noise and vibration produced by high-speed trains on annoyance in buildings.

    Science.gov (United States)

    Lee, Pyoung Jik; Griffin, Michael J

    2013-04-01

    The effects of noise and vibration on annoyance in buildings during the passage of a nearby high-speed train have been investigated in a laboratory experiment with recorded train noise and 20 Hz vibration. The noises included the effects of two types of façade: windows-open and windows-closed. Subjects were exposed to six levels of noise and six magnitudes of vibration, and asked to rate annoyance using an 11-point numerical scale. The experiment consisted of four sessions: (1) evaluation of noise annoyance in the absence of vibration, (2) evaluation of total annoyance from simultaneous noise and vibration, (3) evaluation of noise annoyance in the presence of vibration, and (4) evaluation of vibration annoyance in the absence of noise. The results show that vibration did not influence ratings of noise annoyance, but that total annoyance caused by combined noise and vibration was considerably greater than the annoyance caused by noise alone. The noise annoyance and the total annoyance caused by combined noise and vibration were associated with subject self-ratings of noise sensitivity. Two classical models of total annoyance due to combined noise sources (maximum of the single source annoyance or the integration of individual annoyance ratings) provided useful predictions of the total annoyance caused by simultaneous noise and vibration.

  13. Postmortem serum levels of tryptase and total and specific IgE in fatal asthma.

    Science.gov (United States)

    Salkie, M L; Mitchell, I; Revers, C W; Karkhanis, A; Butt, J; Tough, S; Green, F H

    1998-01-01

    Sera were obtained postmortem from 55 subjects classified into three groups; death due to asthma (FA, n = 21), asthmatic but death not due to asthma (NFA, n = 24) and a nonasthmatic control group (NAC, n = 10). A full autopsy was performed on all cases and a medical history, including details of allergies, was obtained by questionnaire from the next of kin. Grading of asthma severity by either questionnaire or autopsy was comparable (tP = 0.435, p > 0.05) and the mean pathology-grade was significantly higher for the FA group (3.375) compared to the NFA group (2.375), p 2.0 micrograms/L) in 21/55 sera (38%) and there was no significant difference between the groups. ROC plots showed that tryptase levels did not discriminate between the FA and NFA groups, even if specimens were collected within 24 hours after death. Total IgE was significantly elevated in the FA group (geometric mean 140.3 kU/L) compared to the other two groups (NFA 30.2 kU/L, NAC 9.4 kU/L), p = 0.05. Fatal asthmatics also had a greater positivity (67%) to a screen for common inhalant allergens than did the other groups (NFA 30%, NAC 20%). Sera with a positive screen were tested against a panel of 10 common aero-allergens. Each sample was then assigned a number (N) and a score (S), dependent on either the number of allergens positive (N) or the total sum of pluses for all allergens (S). Both the N and S values were higher for the FA group (N = 98, S = 264) than the NFA group (N = 52, S = 151) and NAC group (N = 4, S = 8). The ratio (S/N) which gives an index (I) was 2.69, 2.90, and 2.00, respectively. Tryptase was poorly correlated to the total IgE level (r = 0.036); however, mean values for N and S were significantly different (N 6.81, S 4.50, and N 19.25, S 11.5, p or = 2.0 micrograms/L, respectively. We conclude that total and specific IgE may be useful predictors of asthma severity but that postmortem tryptase is not useful in the diagnosis of a fatal asthmatic attack.

  14. Common mode noise in three-level DC-DC converters

    CSIR Research Space (South Africa)

    Grobler, Inus

    2009-09-01

    Full Text Available that three-level buck DC-DC converters in general generate much lower common mode currents than conventional two-level buck converters. Further, reductions in common mode currents are achieved by using the improved three-level topologies that have been...

  15. Hearing Threshold, Loss, Noise Levels and Worker's Profiles of an Open Cast Chromite Mines in Odisha, India.

    Science.gov (United States)

    Kerketta, Sunamani; Gartia, Rajendra; Bagh, Somanath

    2012-10-01

    The aims of the study were to describe the noise levels at an open cast chromite mine in Odisha, India, and the hearing threshold of its workers and to associate their hearing loss with their age, work station and length of employment at the mine. We performed a cross-sectional study of the hearing threshold of chromite mine workers. Audiometric data from 500 subjects was collected at the mines' hospital in the Sukinda Valley of Jajpur, Odisha, India. The latest audiometry data available for the period 2002 to 2008 was used in the analysis. Audiometric screening was performed using an audiometer (TRIVENI TAM-25 6025A) in a quiet environment by qualified technicians, audiologists or physicians. Tests were conducted on the subjects after they had completely rested for 16 hours or more after their day shift. A maximum of 262 subjects (52.4%) were employed in the work zone area and a minimum of 2 subjects (0.4%) had less than 5 years working experience. The age of the subjects ranged from 29 to 59 years and their working experience ranged from 4 to 37 years. The subjects' average mean hearing thresholds at 4, 6 and 8 kHz were 21.53 dBA, 23.40 dBA and 21.90 dBA, respectively. The maximum Leq and L90 levels exceeded the prescribed limits for commercial, residential and silence zones. The maximum Leq levels exceeded 95 dBA for large and medium heavy earth moving machineries (HEMMs), both outside and at the operator's position. Hearing loss due to the subjects' work experience was found to be greater than that attributable to age and workstation. In our study population, the maximum noise levels for large and medium HEMMs and inside the cabins of HEMMs were found to be more than 95 dBA. This indicates that operators in this particular chromite mine at Odisha, India were exposed to noise levels exceeding 95 dBA for more than 10% of the monitoring time. The subjects' hearing loss was also found to increase for every 10-year age interval and that for every 5 years of work

  16. Noise and vibration levels in artificial polar bear dens as related to selected petroleum exploration and developmental activities

    International Nuclear Information System (INIS)

    Blix, A.S.; Lentfer, J.W.

    1992-01-01

    Petroleum exploration and development are occurring in various locations in the Arctic, where there are important denning sites for polar bears. Petroleum activities usually coincide with winter denning activities by bears, who may abandon dens if subject to prolonged annoyance. A study was carried out to measure noise and vibration levels in artificial polar bear dens at Prudhoe's Bar, Alaska, resulting from seismic testing, drilling and transport. A microphone and an accelerometer were frozen to the floor of the dens, with leads passed through a consolidated snow filled entrance to a truck, tent or helicopter. Tests were carried out on land, sea ice, and next to a drilling tower on an artificial island, which was also used to measure noise levels resulting from a helicopter taking off. It was concluded that the dry and wind-beaten arctic snow muffles both sound and vibration extremely well, and it is unlikely that polar bears in their dens will be disturbed by the type of petroleum-related activities measured, provided they do not take place within 100 m of the dens. 8 refs., 7 figs., 1 tab

  17. Noise genetics: inferring protein function by correlating phenotype with protein levels and localization in individual human cells.

    Directory of Open Access Journals (Sweden)

    Shlomit Farkash-Amar

    2014-03-01

    Full Text Available To understand gene function, genetic analysis uses large perturbations such as gene deletion, knockdown or over-expression. Large perturbations have drawbacks: they move the cell far from its normal working point, and can thus be masked by off-target effects or compensation by other genes. Here, we offer a complementary approach, called noise genetics. We use natural cell-cell variations in protein level and localization, and correlate them to the natural variations of the phenotype of the same cells. Observing these variations is made possible by recent advances in dynamic proteomics that allow measuring proteins over time in individual living cells. Using motility of human cancer cells as a model system, and time-lapse microscopy on 566 fluorescently tagged proteins, we found 74 candidate motility genes whose level or localization strongly correlate with motility in individual cells. We recovered 30 known motility genes, and validated several novel ones by mild knockdown experiments. Noise genetics can complement standard genetics for a variety of phenotypes.

  18. Honey and Vitamin E Restore the Plasma Level of Gonadal Hormones and Improve the Fertilization Capacity in Noise-Stressed Rats

    Directory of Open Access Journals (Sweden)

    Rajabzadeh Asghar

    2015-04-01

    Full Text Available Objective: Noise as a natural teratogenic factor affects the body systems including the reproductive organ to reduce the fertility rate and fetus health. Honey and vitamin E as natural antioxidants protects the sperm released from the reproductive system. This study was conducted to examine the efficacy of honey and vitamin E on fertilization capacity in noise-exposed rats by assessing plasma sexual hormones levels i.e., follicle-stimulating hormone (FSH, luteinizing hormone (LH, and testosterone, altered in relation with noise stress. Materials and Methods: This study was targeted the 24 male rats that randomly were divided into four equal groups including one control group (unexposed to noise stress and three experimental groups pre-induced with noise stress for 50 days and then divided as: no treated, honey and vitamin E treated groups, respectively. Then, the blood samples of experimental and control groups were taken, and the serum level of the sexual hormones was analyzed. Finally, to investigate the fertility capacity of rats, the male rats of all groups were coupled with the female ones. Results: Our results showed that FSH and LH level in noise stressed male rats raised, and the testosterone secretion decreased compared to the control group. Moreover, noise stress injury could reduce weight and the survival rate of the fetus. However, the honey and vitamin E improved the testosterone concentration, declined the plasma FSH and LH level in noise - exposed rats and enhanced the fertility rate. Conclusion: These findings may also spell out a natural curative approach rather than pharmaceutical drugs to optimize of neuroendocrine gonadal axis and testicular integrity induced by pathogenesis stress, i.e., noise and enhance the male fertility capacity.

  19. A cross-country analysis of total factor productivity using micro-level data

    Directory of Open Access Journals (Sweden)

    Murat Şeker

    2018-03-01

    Full Text Available Total factor productivity (TFP is a crucial measure of efficiency and thus an important tool for policymakers. However, research on comparison of TFP performances using micro-level data across developing countries has been limited due to the unavailability of homogenous data sources. This study aims to fill this crucial gap by using a data set which has been collected through a large body of surveys conducted across 69 developing countries following the same methodology. The homogenous nature of the data and the diverse set of questions included in the surveys provide unique opportunity to compare average productivity performances of firms across a large set of characteristics and business environment factors. The analysis performed here provides the groundwork for testing various stylized facts about TFP and its related factors such as exporting, innovation, access to finance, foreign ownership, and regulations across developing countries.

  20. Levels of total mercury in marine organisms from Adriatic Sea, Italy.

    Science.gov (United States)

    Perugini, Monia; Visciano, Pierina; Manera, Maurizio; Zaccaroni, Annalisa; Olivieri, Vincenzo; Amorena, Michele

    2009-08-01

    The presence of total mercury in fish, crustacean and cephalopod from Adriatic Sea, was investigated. The highest concentrations were observed in decreasing order in: Norway lobster (0.97 +/- 0.24 mg/kg; mean +/- SE), European hake (0.59 +/- 0.14 mg/kg), red mullet (0.48 +/- 0.09 mg/kg), blue whiting (0.38 +/- 0.09 mg/kg), Atlantic mackerel (0.36 +/- 0.08 mg/kg) and European flying squid (0.25 +/- 0.03 mg/kg). A significant difference (p fish and fishery products can exceed the maximum levels and stress the need of more information for consumers in particular for people that eat large amount of fish.

  1. Level and distribution of employee exposures to total and respirable wood dust in two Canadian sawmills.

    Science.gov (United States)

    Teschke, K; Hertzman, C; Morrison, B

    1994-03-01

    Personal respirable (N = 230) and total (N = 237) dust measurements were made in two coastal British Columbia sawmills using a sampling strategy that randomly selected workers from all jobs in the mills over two seasons. Information about job title, department, season, weather conditions, location of the job relative to wood-cutting machines, and control measures also was collected at the time of sampling. Only 16 respirable wood dust samples were above the detection limit of 0.08 mg/m3; all 16 had levels industry, but most sawmill investigations report mean wood dust concentrations lower than those measured in the furniture and cabinetmaking industries, where concerns about wood dust exposures initially were raised.

  2. Economical Appraisal of Total Aflatoxin Level in the Poultry Feeds by Fourier Transform Infrared Spectroscopy

    International Nuclear Information System (INIS)

    Sherazai, S.T.H.; Shar, Z.; Iqbal, M.; Sumbal, G.A.

    2013-01-01

    Single-bounce attenuated total reflectance (SB-ATR) Fourier transform infrared (FTIR) spectroscopy has been used for the quantitative determination of total aflatoxins in the broiler poultry feed. An FTIR calibration spanning the range 1-70 micro g/L aflatoxin standards in (70:30, v/v) methanol-water solvent system based on partial least square (PLS) model, developed by relating mid IR region between 3755-950 cm/ sub -1/. The excellent coefficient of various (using 0.998) was achieved with 1.49 relative mean square error of calibration (RMSEC). Aflatoxins from each of eight poultry feeds was extracted and the determined by the widely used commercially available Enzyme-linked Immunosorbent Assay (ELISA) procedure and the SB-ATR/FTIR method. The SB-ATR/FTIR aflatoxins predictions were related to those determined by the ELISA method by linear regression, producing an R value of 0.989 and a SD of +- 2.80 micro g/L. The result of the study clearly indicated that FT-IR spectroscopy due to its rapidity and simplicity along with data manipulation by advance computer software could be effectively used for routine determination of aflatoxins present in the poultry feeds at very low level. (author)

  3. Determination and assessment of total mercury levels in local, frozen and canned fish in Lebanon.

    Science.gov (United States)

    Obeid, Pierre J; El-Khoury, Bilal; Burger, Joanne; Aouad, Samer; Younis, Mira; Aoun, Amal; El-Nakat, John Hanna

    2011-01-01

    Fish is an important constituent of the Lebanese diet. However, very little attention in our area is given to bring awareness regarding the effect of the toxicity of mercury (Hg) mainly through fish consumption. This study aimed to report analytical data on total mercury levels in several fish species for the first time in thirty years and to also made individuals aware of the presence and danger from exposure to mercury through fish consumption. Fish samples were selected from local Lebanese markets and fisheries and included 94 samples of which were fresh, frozen, processed, and canned fish. All values were reported as microgram of mercury per gram of fish based on wet weight. The level of mercury ranged from 0.0190 to 0.5700 microg/g in fresh samples, 0.0059 to 0.0665 microg/g in frozen samples, and 0.0305 to 0.1190 microg/g in canned samples. The data clearly showed that higher levels of mercury were detected in local fresh fish as opposed to other types thus placing consumers at higher risk from mercury exposure. Moreover, the data revealed that Mallifa (yellowstripe barracuda/Sphyraena chrysotaenia), Sargous (white seabream/Diplodus sargus), Ghobbos (bogue/Boops boops), and shrimp (Penaeus sp.) were among the types containing the highest amounts of mercury. On the other hand, processed fish such as fish fillet, fish burger, small shrimp and crab are found to contain lower levels of mercury and are associated with lower exposure risks to mercury. Lebanese population should therefore, be aware to consume limited amounts of fresh local fish to minimize exposure to mercury.

  4. Serum total bilirubin levels are negatively correlated with metabolic syndrome in aged Chinese women: a community-based study.

    Science.gov (United States)

    Zhong, P; Sun, D M; Wu, D H; Li, T M; Liu, X Y; Liu, H Y

    2017-01-26

    We evaluated serum total bilirubin levels as a predictor for metabolic syndrome (MetS) and investigated the relationship between serum total bilirubin levels and MetS prevalence. This cross-sectional study included 1728 participants over 65 years of age from Eastern China. Anthropometric data, lifestyle information, and previous medical history were collected. We then measured serum levels of fasting blood-glucose, total cholesterol, triglycerides, and total bilirubin, as well as alanine aminotransferase activity. The prevalence of MetS and each of its individual component were calculated per quartile of total bilirubin level. Logistic regression was used to assess the correlation between serum total bilirubin levels and MetS. Total bilirubin level in the women who did not have MetS was significantly higher than in those who had MetS (Pbilirubin quartiles were linearly and negatively correlated with MetS prevalence and hypertriglyceridemia (HTG) in females (Pbilirubin was an independent predictor of MetS for females (OR: 0.910, 95%CI: 0.863-0.960; P=0.001). The present study suggests that physiological levels of serum total bilirubin might be an independent risk factor for aged Chinese women, and the prevalence of MetS and HTG are negatively correlated to serum total bilirubin levels.

  5. WHO Environmental Noise Guidelines for the European Region: A Systematic Review on Environmental Noise and Annoyance

    Directory of Open Access Journals (Sweden)

    Rainer Guski

    2017-12-01

    Full Text Available Background: This paper describes a systematic review and meta-analyses on effects of environmental noise on annoyance. The noise sources include aircraft, road, and rail transportation noise as well as wind turbines and noise source combinations. Objectives: Update knowledge about effects of environmental noise on people living in the vicinity of noise sources. Methods: Eligible were published studies (2000–2014 providing comparable acoustical and social survey data including exposure-response functions between standard indicators of noise exposure and standard annoyance responses. The systematic literature search in 20 data bases resulted in 62 studies, of which 57 were used for quantitative meta-analyses. By means of questionnaires sent to the study authors, additional study data were obtained. Risk of bias was assessed by means of study characteristics for individual studies and by funnel plots to assess the risk of publication bias. Main Results: Tentative exposure-response relations for percent highly annoyed residents (%HA in relation to noise levels for aircraft, road, rail, wind turbine and noise source combinations are presented as well as meta-analyses of correlations between noise levels and annoyance raw scores, and the OR for increase of %HA with increasing noise levels. Quality of evidence was assessed using the GRADE terminology. The evidence of exposure-response relations between noise levels and %HA is moderate (aircraft and railway or low (road traffic and wind turbines. The evidence of correlations between noise levels and annoyance raw scores is high (aircraft and railway or moderate (road traffic and wind turbines. The evidence of ORs representing the %HA increase by a certain noise level increase is moderate (aircraft noise, moderate/high (road and railway traffic, and low (wind turbines. Strengths and Limitations: The strength of the evidence is seen in the large total sample size encompassing the included studies (e

  6. Influence of military low-level flight noise on the inner ear of guinea pigs. Der Einfluss von militaerischem Tieffluglaerm auf das Innenohr des Meerschweinchens

    Energy Technology Data Exchange (ETDEWEB)

    Gehrig, W.; Meyer, P.; Kuhl, K.D.; Schmidt, R.; Gruetzmacher, W. (Greifswald Univ. (Germany). HNO-Klinik); Ising, H. (BGA, Berlin (Germany). Inst. fuer Wasser-, Boden- und Lufthygiene); Ishi, K.; Merker, H.J. (Freie Univ. Berlin (Germany). Inst. fuer Anatomie)

    1992-03-01

    The influence of different rises in noise level and - in cases of the repeated passage of aircraft - the impact of varying intervals between the events was to be investigated. The experimental animals used were pigmented guinea pigs of 250 to 500 grammes body weight. The auditory thresholds were measured on the anaesthesized animals by derivation of the acoustically evoked brain stem potentials from the EEGs. For the noise exposure of the animals, two types of military low-level flight noise were used: one flight overhead with a rise in noise level of 7.5 dB/s, and a second one with 75 dB/s.-unlike other cases of damage to the inner ear through noise, the damage sustained in this case was not restricted to the basal convolution but was observed in all four cochlear convolutions. This suggests a particularity of the harmful effect of low-level flight noise, which it is planned to follow up in the future. (orig./MG).

  7. Perioperative plasmatic presepsin levels in patients undergoing total hip or knee replacement: a preliminary study.

    Science.gov (United States)

    Vicenti, G; Pesce, V; Bizzoca, D; Nappi, V; Palmiotto, F; Carrozzo, M; Moretti, B

    2017-01-01

    Presepsin (sCD14-ST) is an emerging biomarker in the diagnosis of sepsis. In the field of orthopaedics, it could be useful in the diagnosis and management of periprosthetic joint infections (PJI). The aim of this study is to define the normal perioperative plasmatic levels of presepsin in patients undergoing primary cementless total hip replacement (THR) or primary cemented total knee replacement (TKR). For this purpose, 50 patients (19 male, 31 female, mean age= 64.04±8.88) were recruited. The patients were divided into two groups: Group A patients underwent cementless THR, whereas Group B patients underwent cemented TKR. On recruitment, anthropometric data, smocking status, osteoarthritis stage according to Kellgren and Lawrence, Harris Hip Score (HHS) for Group A patients and Knee Society Score (KSS) for Group B patients, drugs assumption and comorbidities were recorded. All the patients underwent serial blood tests, including complete blood count, presepsin (PS), C-reactive protein (CRP) and procalcitonin (PCT) 24 hours before arthroplasty (T0) and at 24 (T1), 48 (T2), 72 (T3) and 96 (T4) hours postoperatively. Body temperature (θ) was recorded every six hours in the time lapse T0-T4. Presepsin plasmatic concentration was comparable at baseline in both groups. After surgery, however, a significant increase of presepsin was observed in Group A, whereas in Group B no significant changes of presepsin were recorded. A comparable trend of this biomarker was found in the two groups, i.e. presepsin increased from T0 to T3, when it reached its maximum value, and its decrease started at T4. Finally, presepsin resulted more accurate than CRP in the evaluation of perioperative inflammatory response in patients undergoing THR or TKR. These data will be helpful in defining a reference interval for presepsin in patients with prosthetic joint implants, and a cut-off of this biomarker for the diagnosis of PJI.

  8. Drone noise

    Science.gov (United States)

    Tinney, Charles; Sirohi, Jayant; University of Texas at Austin Team

    2017-11-01

    A basic understanding of the noise produced by single and multirotor drones operating at static thrust conditions is presented. This work acts as an extension to previous efforts conducted at The University of Texas at Austin (Tinney et al. 2017, AHS Forum 73). Propeller diameters ranging from 8 inch to 12 inch are examined for configurations comprising an isolated rotor, a quadcopter configuration and a hexacopter configuration, and with a constant drone pitch of 2.25. An azimuthal array of half-inch microphones, placed between 2 and 3 hub-center diameters from the drone center, are used to assess the acoustic near-field. Thrust levels, acquired using a six degree-of-freedom load cell, are then used to correlate acoustic noise levels to aerodynamic performance for each drone configuration. The findings reveal a nearly logarithmic increase in noise with increasing thrust. However, for the same thrust condition, considerable noise reduction is achieved by increasing the number of propeller blades thereby reducing the blade passage frequency and both the thickness and loading noise sources that accompany it.

  9. Measuring changes in ambient noise levels from the installation and operation of a surge wave energy converter in the coastal ocean

    Energy Technology Data Exchange (ETDEWEB)

    Haxel, Joe H [Oregon State Univ., Newport, OR (United States); Henkel, Sarah K [Oregon State Univ., Newport, OR (United States)

    2017-10-18

    Ecosystem impacts resulting from elevated underwater noise levels generated by anthropogenic activities in the coastal ocean are poorly understood and remain difficult to address as a result of a significant gap in knowledge for existing nearshore sound levels. Ambient noise is an important habitat component for marine mammals and fish that use sound for essential functions such as communication, navigation, and foraging. Questions surrounding the amplitudes, frequency distributions, and durations of noise emissions from renewable wave energy conversion (WEC) projects during their construction and operation present concerns for long-term consequences in marine habitats. Oregon’s dynamic nearshore environment presents significant challenges for passive acoustic monitoring that include flow noise contamination from wave orbital motions, turbulence from breaking surf, equipment burial, and fishing pressure from sport and commercial crabbers. This project included 2 techniques for passive acoustic data collection: 1) campaign style deployments of fixed hydrophone lander stations to capture temporal variations in noise levels and 2) a drifting hydrophone system to record spatial variations within the project site. The hydrophone lander deployments were effective and economically feasible for enabling robust temporal measurements of ambient noise levels in a variety of sea state conditions. Limiting factors for the fixed stations included 1) a flow shield mitigation strategy failure in the first deployment resulting in significant wideband data contamination and 2) flow noise contamination of the unshielded sensors restricting valuable analysis to frequencies above 500 Hz for subsequent deployments. Drifting hydrophone measurements were also effective and economically feasible (although logistically challenging in the beginning of the project due to vessel time constraints) providing a spatial distribution of sound levels, comparisons of noise levels in varying levels

  10. Background Noise Analysis in a Few-Photon-Level Qubit Memory

    Science.gov (United States)

    Mittiga, Thomas; Kupchak, Connor; Jordaan, Bertus; Namazi, Mehdi; Nolleke, Christian; Figeroa, Eden

    2014-05-01

    We have developed an Electromagnetically Induced Transparency based polarization qubit memory. The device is composed of a dual-rail probe field polarization setup colinear with an intense control field to store and retrieve any arbitrary polarization state by addressing a Λ-type energy level scheme in a 87Rb vapor cell. To achieve a signal-to-background ratio at the few photon level sufficient for polarization tomography of the retrieved state, the intense control field is filtered out through an etalon filtrating system. We have developed an analytical model predicting the influence of the signal-to-background ratio on the fidelities and compared it to experimental data. Experimentally measured global fidelities have been found to follow closely the theoretical prediction as signal-to-background decreases. These results suggest the plausibility of employing room temperature memories to store photonic qubits at the single photon level and for future applications in long distance quantum communication schemes.

  11. THE ASSOCIATION BETWEEN G6PD DEFICIENCY AND TOTAL SERUM BILIRUBIN LEVEL IN ICTERIC NEONATES

    Directory of Open Access Journals (Sweden)

    S. Behjati-Ardakani

    2007-07-01

    Full Text Available "nGlucose-6-phosphate dehydrogenase (G6PD deficiency is the most important disease of the hexose monophosphate pathway. Deficiency of this enzym can lead to hemolysis of red blood cells. Our aim was to study the prevalence of G6PD deficiency in relation to neonatal jaundice. We studied 456 clinically icteric neonates Laboratory investigations included determination of direct and indirect serum bilirubin concentrations, blood group typing, direct coomb's test, hemoglobin, blood smear, reticulocyte count and G6PD level. We divided these neonates to 3 groups based on total serum bilirubin level (TSB: TSB< 20 mg%, TSB=20-25 mg%, and TSB>25 mg%. In only 35 (7.6% of cases G6PD deficiency was diagnosed. All of these babies were male. From 456 icteric neonates, 213 cases belong to group 1 (TSB<20 mg%, 158 cases belong to group 2 (TSB=20-25 mg% and 85 cases belong to group 3 (TSB>25 mg%. 16 neonates from 213 neonates of group 1, 6 neonates from 158 neonates of group 2 and 13 neonates from 85 neonates of group 3 had G6PD deficiency. There was statistically significant difference of prevalence of G6PD deficiency between group 2 and 3 ( 15.3% vs 3.8%( P = 0.001. Between groups 1 vs 2 and 1 vs 3 no statistically significant difference was found. Early detection of this enzymopathy regardless of sex and close surveillance of the affected newborns may be important in reducing the risk of severe hyperbilirubinemia. This emphasizes the necessity of neonatal screening on cord blood samples for G6PD deficiency.

  12. Levels of lead in foods from the first French total diet study on infants and toddlers.

    Science.gov (United States)

    Guérin, Thierry; Le Calvez, Emilie; Zinck, Julie; Bemrah, Nawel; Sirot, Véronique; Leblanc, Jean-Charles; Chekri, Rachida; Hulin, Marion; Noël, Laurent

    2017-12-15

    Infants and toddlers are highly vulnerable to exposure to lead due to its higher absorption in small children than in adults. This study describes the optimisation and validation of a very sensitive method for the determination of low levels of lead in foods mostly consumed by infants and toddlers. This method, based on inductively coupled plasma-mass spectrometry with a programmable temperature cyclonic spray chamber, attained a limit of quantification (LOQ) of 0.6 or 0.9µgPbkg -1 for a liquid or a solid sample, that was improved by a factor 5.6-8.3 compared to the previous method (LOQ: 5µgkg -1 ). The analytical method was then applied to 291 food samples from the first French total diet study on infants and toddlers. Lead was detected in most samples at relatively low concentrations (range 0.0-16µgkg -1 ). The highest lead concentrations were mainly found in processed food products (e.g. products containing chocolate). Copyright © 2017 Elsevier Ltd. All rights reserved.

  13. Measurement of Deformations by MEMS Arrays, Verified at Sub-millimetre Level Using Robotic Total Stations

    Directory of Open Access Journals (Sweden)

    Tomas Beran

    2014-06-01

    Full Text Available Measurement of sub-millimetre-level deformations of structures in the presence of ambienttemperature changes can be challenging. This paper describes the measurement of astructure moving due to temperature changes, using two ShapeAccelArray (SAAinstruments, and verified by a geodetic monitoring system. SAA is a geotechnicalinstrument often used for monitoring of displacements in soil. SAA uses micro-electro-mechanical system (MEMS sensors to measure tilt in the gravity field. The geodeticmonitoring system, which uses ALERT software, senses the displacements of targetsrelative to control points, using a robotic total station (RTS. The test setup consists of acentral four-metre free-standing steel tube with other steel tubes welded to most of itslength. The central tube is anchored in a concrete foundation. This composite “pole” isequipped with two SAAs as well as three geodetic prisms mounted on the top, in the middle,and in the foundation. The geodetic system uses multiple control targets mounted inconcrete foundations of nearby buildings, and at the base of the pole. Long-termobservations using two SAAs indicate that the pole is subject to deformations due to cyclicalambient temperature variations causing the pole to move by a few millimetres each day. Ina multiple-day experiment, it was possible to track this movement using SAA as well as theRTS system. This paper presents data comparing the measurements of the two instrumentsand provides a good example of the detection of two-dimensional movements of seeminglyrigid objects due to temperature changes.

  14. 1H-MRS evaluation of breast lesions by using total choline signal-to-noise ratio as an indicator of malignancy: a meta-analysis.

    Science.gov (United States)

    Wang, Xin; Wang, Xiang Jiang; Song, Hui Sheng; Chen, Long Hua

    2015-05-01

    The aim of this study was to evaluate the diagnostic performance of the use of total choline signal-to-noise ratio (tCho SNR) criteria in MRS studies for benign/malignant discrimination of focal breast lesions. We conducted (1) a meta-analysis based on 10 studies including 480 malignant breast lesions and 312 benign breast lesions and (2) a subgroup meta-analysis of tCho SNR ≥ 2 as cutoff for malignancy based on 7 studies including 371 malignant breast lesions and 239 benign breast lesions. (1) The pooled sensitivity and specificity of proton MRS with tCho SNR were 0.74 (95 % CI 0.69-0.77) and 0.76 (95 % CI 0.71-0.81), respectively. The PLR and NLR were 3.67 (95 % CI 2.30-5.83) and 0.25 (95 % CI 0.14-0.42), respectively. From the fitted SROC, the AUC and Q* index were 0.89 and 0.82. Publication bias was present (t = 2.46, P = 0.039). (2) Meta-regression analysis suggested that neither threshold effect nor evaluated covariates including strength of field, pulse sequence, TR and TE were sources of heterogeneity (all P value >0.05). (3) Subgroup meta-analysis: The pooled sensitivity and specificity were 0.79 and 0.72, respectively. The PLR and NLR were 3.49 and 0.20, respectively. The AUC and Q* index were 0.92 and 0.85. The use of tCho SNR criteria in MRS studies was helpful for differentiation between malignant and benign breast lesions. However, pooled diagnostic measures might be overestimated due to publication bias. A tCho SNR ≥ 2 as cutoff for malignancy resulted in higher diagnostic accuracy.

  15. Effect of ultra-low doses, ASIR and MBIR on density and noise levels of MDCT images of dental implant sites

    Energy Technology Data Exchange (ETDEWEB)

    Widmann, Gerlig; Schullian, Peter [Medical University of Innsbruck, Department of Radiology, Innsbruck (Austria); Al-Shawaf, Reema; Al-Sadhan, Ra' ed; Al-Ekrish, Asma' a A. [King Saud University, Department of Oral Medicine and Diagnostic Sciences, College of Dentistry, Riyadh (Saudi Arabia); Hoermann, Romed [Medical University of Innsbruck, Division of Clinical and Functional Anatomy, Innsbruck (Austria)

    2017-05-15

    Differences in noise and density values in MDCT images obtained using ultra-low doses with FBP, ASIR, and MBIR may possibly affect implant site density analysis. The aim of this study was to compare density and noise measurements recorded from dental implant sites using ultra-low doses combined with FBP, ASIR, and MBIR. Cadavers were scanned using a standard protocol and four low-dose protocols. Scans were reconstructed using FBP, ASIR-50, ASIR-100, and MBIR, and either a bone or standard reconstruction kernel. Density (mean Hounsfield units [HUs]) of alveolar bone and noise levels (mean standard deviation of HUs) was recorded from all datasets and measurements were compared by paired t tests and two-way ANOVA with repeated measures. Significant differences in density and noise were found between the reference dose/FBP protocol and almost all test combinations. Maximum mean differences in HU were 178.35 (bone kernel) and 273.74 (standard kernel), and in noise, were 243.73 (bone kernel) and 153.88 (standard kernel). Decreasing radiation dose increased density and noise regardless of reconstruction technique and kernel. The effect of reconstruction technique on density and noise depends on the reconstruction kernel used. (orig.)

  16. Effect of ultra-low doses, ASIR and MBIR on density and noise levels of MDCT images of dental implant sites

    International Nuclear Information System (INIS)

    Widmann, Gerlig; Schullian, Peter; Al-Shawaf, Reema; Al-Sadhan, Ra'ed; Al-Ekrish, Asma'a A.; Hoermann, Romed

    2017-01-01

    Differences in noise and density values in MDCT images obtained using ultra-low doses with FBP, ASIR, and MBIR may possibly affect implant site density analysis. The aim of this study was to compare density and noise measurements recorded from dental implant sites using ultra-low doses combined with FBP, ASIR, and MBIR. Cadavers were scanned using a standard protocol and four low-dose protocols. Scans were reconstructed using FBP, ASIR-50, ASIR-100, and MBIR, and either a bone or standard reconstruction kernel. Density (mean Hounsfield units [HUs]) of alveolar bone and noise levels (mean standard deviation of HUs) was recorded from all datasets and measurements were compared by paired t tests and two-way ANOVA with repeated measures. Significant differences in density and noise were found between the reference dose/FBP protocol and almost all test combinations. Maximum mean differences in HU were 178.35 (bone kernel) and 273.74 (standard kernel), and in noise, were 243.73 (bone kernel) and 153.88 (standard kernel). Decreasing radiation dose increased density and noise regardless of reconstruction technique and kernel. The effect of reconstruction technique on density and noise depends on the reconstruction kernel used. (orig.)

  17. Effects of Dry Storage and Resubmersion of Oysters on Total Vibrio vulnificus and Total and Pathogenic (tdh+/trh+) Vibrio parahaemolyticus Levels.

    Science.gov (United States)

    Kinsey, Thomas P; Lydon, Keri A; Bowers, John C; Jones, Jessica L

    2015-08-01

    Vibrio vulnificus (Vv) and Vibrio parahaemolyticus (Vp) are the two leading causes of bacterial illnesses associated with raw shellfish consumption. Levels of these pathogens in oysters can increase during routine antifouling aquaculture practices involving dry storage in ambient air conditions. After storage, common practice is to resubmerge these stored oysters to reduce elevated Vv and Vp levels, but evidence proving the effectiveness of this practice is lacking. This study examined the changes in Vv and in total and pathogenic (thermostable direct hemolysin gene and the tdh-related hemolysin gene, tdh+ and trh+) Vp levels in oysters after 5 or 24 h of dry storage (28 to 32°C), followed by resubmersion (27 to 32°C) for 14 days. For each trial, replicate oyster samples were collected at initial harvest, after dry storage, after 7 days, and after 14 days of resubmersion. Oysters not subjected to dry storage were collected and analyzed to determine natural undisturbed vibrio levels (background control). Vibrio levels were measured using a most-probable-number enrichment followed by real-time PCR. After storage, vibrio levels (excluding tdh+ and trh+ Vp during 5-h storage) increased significantly (P oysters stored for 5 h) were not significantly different (P oysters. Vv and total and pathogenic Vp levels were not significantly different (P > 0.1) from levels in background oysters after 14 days of resubmersion, regardless of dry storage time. These data demonstrate that oyster resubmersion after dry storage at elevated ambient temperatures allows vibrio levels to return to those of background control samples. These results can be used to help minimize the risk of Vv and Vp illnesses and to inform the oyster industry on the effectiveness of routine storing and resubmerging of aquaculture oysters.

  18. Noise and Hearing Loss Prevention

    Science.gov (United States)

    ... message, please visit this page: About CDC.gov . NOISE AND HEARING LOSS PREVENTION Language: English (US) Español ( ... when hazardous noise levels cannot be adequately reduced. Noise and Hearing Loss on the NIOSH Science Blog ...

  19. A study on the contribution of body vibrations to the vibratory sensation induced by high-level, complex low-frequency noise

    Directory of Open Access Journals (Sweden)

    Yukio Takahashi

    2011-01-01

    Full Text Available To investigate the contribution of body vibrations to the vibratory sensation induced by high-level, complex low-frequency noise, we conducted two experiments. In Experiment 1, eight male subjects were exposed to seven types of low-frequency noise stimuli: two pure tones [a 31.5-Hz, 100-dB(SPL tone and a 50-Hz, 100-dB(SPL tone] and five complex noises composed of the pure tones. For the complex noise stimuli, the sound pressure level of one tonal component was 100 dB(SPL and that of another one was either 90, 95, or 100 dB(SPL. Vibration induced on the body surface was measured at five locations, and the correlation with the subjective rating of the vibratory sensation at each site of measurement was examined. In Experiment 2, the correlation between the body surface vibration and the vibratory sensation was similarly examined using seven types of noise stimuli composed of a 25-Hz tone and a 50-Hz tone. In both the experiments, we found that at the chest and the abdomen, the rating of the vibratory sensation was in close correlation with the vibration acceleration level (VAL of the body surface vibration measured at each corresponding location. This was consistent with our previous results and suggested that at the trunk of the body (the chest and the abdomen, the mechanoreception of body vibrations plays an important role in the experience of the vibratory sensation in persons exposed to high-level low-frequency noise. At the head, however, no close correlation was found between the rating of the vibratory sensation and the VAL of body surface vibration. This suggested that at the head, the perceptual mechanisms of vibration induced by high-level low-frequency noise were different from those in the trunk of the body.

  20. Effect of ultra-low doses, ASIR and MBIR on density and noise levels of MDCT images of dental implant sites.

    Science.gov (United States)

    Widmann, Gerlig; Al-Shawaf, Reema; Schullian, Peter; Al-Sadhan, Ra'ed; Hörmann, Romed; Al-Ekrish, Asma'a A

    2017-05-01

    Differences in noise and density values in MDCT images obtained using ultra-low doses with FBP, ASIR, and MBIR may possibly affect implant site density analysis. The aim of this study was to compare density and noise measurements recorded from dental implant sites using ultra-low doses combined with FBP, ASIR, and MBIR. Cadavers were scanned using a standard protocol and four low-dose protocols. Scans were reconstructed using FBP, ASIR-50, ASIR-100, and MBIR, and either a bone or standard reconstruction kernel. Density (mean Hounsfield units [HUs]) of alveolar bone and noise levels (mean standard deviation of HUs) was recorded from all datasets and measurements were compared by paired t tests and two-way ANOVA with repeated measures. Significant differences in density and noise were found between the reference dose/FBP protocol and almost all test combinations. Maximum mean differences in HU were 178.35 (bone kernel) and 273.74 (standard kernel), and in noise, were 243.73 (bone kernel) and 153.88 (standard kernel). Decreasing radiation dose increased density and noise regardless of reconstruction technique and kernel. The effect of reconstruction technique on density and noise depends on the reconstruction kernel used. • Ultra-low-dose MDCT protocols allowed more than 90 % reductions in dose. • Decreasing the dose generally increased density and noise. • Effect of IRT on density and noise varies with reconstruction kernel. • Accuracy of low-dose protocols for interpretation of bony anatomy not known. • Effect of low doses on accuracy of computer-aided design models unknown.

  1. Comparison of Transcutaneous Bilirubin Measurement With Total Serum Bilirubin Levels in Preterm Neonates Receiving Phototherapy.

    Science.gov (United States)

    Pendse, Amruta; Jasani, Bonny; Nanavati, Ruchi; Kabra, Nandkishor

    2017-08-15

    To compare transcutaneous bilirubin with total serum bilirubin in preterm neonates after initiation of phototherapy. Jaundice was assessed in 30 preterm neonates with transcutaneous bilirubin and total serum bilirubin before initiation of phototherapy and at 12 hr after initiation of phototherapy. A photo-occlusive patch was applied over the sternum. Transcutaneous bilirubin has a good correlation with total serum bilirubin after initiation of phototherapy. (r=0.918, Pbilirubin at 28-32 weeks of gestation (r = 0.97) was better correlated with total serum bilirubin than those at 32-37 weeks (r =0.88). The correlation was better for neonates 72 hours of age (r = 0.82). Transcutaneous bilirubin correlates significantly with total serum bilirubin at the patched sternal site after initiation of phototherapy in preterm neonates.

  2. Detecting anthropogenic footprints in sea level rise: the role of complex colored noise

    Science.gov (United States)

    Dangendorf, Sönke; Marcos, Marta; Müller, Alfred; Zorita, Eduardo; Jensen, Jürgen

    2015-04-01

    While there is scientific consensus that global mean sea level (MSL) is rising since the late 19th century, it remains unclear how much of this rise is due to natural variability or anthropogenic forcing. Uncovering the anthropogenic contribution requires profound knowledge about the persistence of natural MSL variations. This is challenging, since observational time series represent the superposition of various processes with different spectral properties. Here we statistically estimate the upper bounds of naturally forced centennial MSL trends on the basis of two separate components: a slowly varying volumetric (mass and density changes) and a more rapidly changing atmospheric component. Resting on a combination of spectral analyses of tide gauge records, ocean reanalysis data and numerical Monte-Carlo experiments, we find that in records where transient atmospheric processes dominate, the persistence of natural volumetric changes is underestimated. If each component is assessed separately, natural centennial trends are locally up to ~0.5 mm/yr larger than in case of an integrated assessment. This implies that external trends in MSL rise related to anthropogenic forcing might be generally overestimated. By applying our approach to the outputs of a centennial ocean reanalysis (SODA), we estimate maximum natural trends in the order of 1 mm/yr for the global average. This value is larger than previous estimates, but consistent with recent paleo evidence from periods in which the anthropogenic contribution was absent. Comparing our estimate to the observed 20th century MSL rise of 1.7 mm/yr suggests a minimum external contribution of at least 0.7 mm/yr. We conclude that an accurate detection of anthropogenic footprints in MSL rise requires a more careful assessment of the persistence of intrinsic natural variability.

  3. Quantification of total aluminium concentrations in food samples at trace levels by INAA and PIGE methods

    International Nuclear Information System (INIS)

    Nanda, Braja B.; Acharya, R.

    2017-01-01

    Total aluminium contents in various food samples were determined by Instrumental Neutron Activation Analysis (INAA) and Particle Induced Gamma-ray Emission (PIGE) methods. A total of 16 rice samples, collected from the field, were analyzed by INAA using reactor neutrons from Dhruva reactor. Whereas a total 17 spices collected from market, were analyzed by both INAA and PIGE methods in conjunction with high resolution gamma-ray spectrometry. Aluminium concentration values were found to be in the range of 19-845 mg kg -1 for spices and 15-104 mg kg -1 for rice samples. The methods were validated by analyzing standard reference materials (SRMs) form NIST. (author)

  4. Patient Activity Levels After Reverse Total Shoulder Arthroplasty: What Are Patients Doing?

    Science.gov (United States)

    Garcia, Grant H; Taylor, Samuel A; DePalma, Brian J; Mahony, Gregory T; Grawe, Brian M; Nguyen, Joseph; Dines, Joshua S; Dines, David M; Warren, Russell F; Craig, Edward V; Gulotta, Lawrence V

    2015-11-01

    The indications for reverse total shoulder arthroplasty (RTSA) continue to expand, which has resulted in younger patients who want to remain active after RTSA. Little information is available to manage expectations of both physicians and patients for return to sporting activities. To determine the rate of return to sporting activities and assess average time to return to sports after RTSA. Case series; Level of evidence, 4. This was a retrospective review of consecutive RTSA patients collected from our institution's shoulder arthroplasty registry. All patients who played sports preoperatively and had a minimum of 1-year follow-up were included. Final follow-up consisted of an additional patient-reported questionnaire with questions regarding physical fitness and sporting activities. Each patient also completed an assessment with the American Shoulder and Elbow Society (ASES) Shoulder Score and a visual analog scale (VAS) for pain. Seventy-six patients played a sport preoperatively and met inclusion and exclusion criteria. The average follow-up was 31.6 months (range, 12-65 months), and average age was 74.8 years (range, 49.9-92.6 years). Average VAS pain scores improved from 6.57 to 0.63 (P sport. Average time to return to full sports was 5.3 months. Fitness sports had the highest direct rate of return (81.5%), followed by swimming (66.7%), running (57.1%), cycling (50.0%), and golf (50%). Postoperatively, 41.1% of patients reported improved physical fitness; 88.2% felt that their sports outcome was good to excellent, and 93.4% felt that their surgical outcome was good to excellent. Patients undergoing RTSA had an 85% rate of return to 1 or more sporting activities at an average of 5.3 months after surgery. Age greater than 70 years was a significant predictor of decreased return to activities. The present study offers valuable information to help manage patient and surgeon expectations. © 2015 The Author(s).

  5. Total Quality Management in the Classroom: Applications to University-Level Mathematics.

    Science.gov (United States)

    Williams, Frank

    1995-01-01

    Describes a Total Quality Management-based system of instruction that is used in a variety of undergraduate mathematics courses. The courses that incorporate this approach include mathematics appreciation, introductory calculus, and advanced applied linear algebra. (DDR)

  6. Thyrocalcitonin: its importance on the regulation of the plasmatic levels in total thyroidectomy

    International Nuclear Information System (INIS)

    Fridman, J.

    1975-01-01

    Effect of thyrocalcitonin ou calcium and blood phosphorus is studied. Twelve patients with adenocarcinoma of the thyroid, previously submited to total thyroidectomy and complementary radioiodine theraphy, are studied [pt

  7. Relationship Between Total and Bioaccessible Lead on Children’s Blood Lead Levels in Urban Residential Philadelphia Soils

    Science.gov (United States)

    Relationships between total soil or bioaccessible lead (Pb), measured using an in vitro bioaccessibility assay, and children’s blood lead levels (BLL) were investigated in an urban neighborhood in Philadelphia, Pennsylvania, USA, with a history of soil Pb contamination....

  8. Effects of nocturnal railway noise on sleep fragmentation in young and middle-aged subjects as a function of type of train and sound level.

    Science.gov (United States)

    Saremi, Mahnaz; Grenèche, Jérôme; Bonnefond, Anne; Rohmer, Odile; Eschenlauer, Arnaud; Tassi, Patricia

    2008-12-01

    Due to undisputable effects of noise on sleep structure, especially in terms of sleep fragmentation, the expected development of railway transportation in the next few years might represent a potential risk factor for people living alongside the rail tracks. The aim of this study was to compare the effects of different types of train (freight, automotive, passenger) on arousal from sleep and to determine any differential impact as a function of sound level and age. Twenty young (16 women, 4 men; 25.8 years+/-2.6) and 18 middle-aged (15 women, 3 men; 52.2 years+/-2.5) healthy subjects participated in three whole-night polysomnographic recordings including one control night (35 dBA), and two noisy nights with equivalent noise levels of 40 or 50 dB(A), respectively. Arousal responsiveness increased with sound level. It was the highest in S2 and the lowest in REM sleep. Micro-arousals (3-10 s) occurred at a rate of 25-30%, irrespective of the type of train. Awakenings (>10 s) were produced more frequently by freight train than by automotive and passenger trains. Normal age-related changes in sleep were observed, but they were not aggravated by railway noise, thus questioning whether older persons are less sensitive to noise during sleep. These evidences led to the conclusion that microscopic detection of sleep fragmentation may provide advantageous information on sleep disturbances caused by environmental noises.

  9. Aircrafts' taxi noise emission

    NARCIS (Netherlands)

    Asensio, C.; Pagan Munoz, Raul; López, J.M.

    2008-01-01

    An investigation has been conducted, with the objective of creating a database of inputs that can be used with noise prediction software, to evaluate noise of aircraft taxing movements and community noise exposure levels. The acoustic consultant can use these data with any of the software packages,

  10. Non-auditory effects of noise in industry. VI. A final field study in industry

    NARCIS (Netherlands)

    van Dijk, F. J.; Souman, A. M.; de Vries, F. F.

    1987-01-01

    Non-auditory effects of noise were studied among 539 male workers from seven industries. The LAeq, assessed by personal noise dosimetry, has been used to study acute effects. Various indices of total noise exposure, involving level and duration, were developed for long-term effect studies. In the

  11. Increased total-Tau levels in cerebrospinal fluid of pediatric hydrocephalus and brain tumor patients

    NARCIS (Netherlands)

    de Bont, Judith M.; Vanderstichele, Hugo; Reddingius, Roel E.; Pieters, Rob; van Gool, Stefdan W.

    Total Tau (t-Tau), hyperphosphorylated Tau (p-Tau((181P))) and beta-amyloid((1-42)) in cerebrospinal fluid (CSF) have shown to be markers of neuronal and axonal degeneration in various neurological and neurodegenerative diseases. The aim of this study was to evaluate the influence of the presence of

  12. Serum iron and total iron binding capacity levels among the abo ...

    African Journals Online (AJOL)

    Iron deficiency anaemia is a common tropical disease. Iron plays a very important role in the human body. The understanding of the different blood groups ability to retain iron in their system can give an insight into their ability to handle the disease Iron deficiency anaemia. Serum Iron, Total Iron Binding Capacity (TIBC) and ...

  13. Dietary factors associated with plasma high molecular weight and total adiponectin levels in apparently healthy women

    NARCIS (Netherlands)

    Yannakoulia, Mary; Yiannakouris, Nikos; Melistas, Labros; Fappa, Evaggelia; Vidra, Nikoletta; Kontogianni, Meropi D; Mantzoros, Christos S

    2008-01-01

    OBJECTIVE: Our aim was to investigate associations between dietary factors and high molecular weight (HMW) as well as total adiponectin in a sample of apparently healthy adult Mediterranean women. DESIGN AND METHODS: Two hundred and twenty women were enrolled in this study. Anthropometric and body

  14. Daily total physical activity level and total cancer risk in men and women: results from a large-scale population-based cohort study in Japan.

    Science.gov (United States)

    Inoue, Manami; Yamamoto, Seiichiro; Kurahashi, Norie; Iwasaki, Motoki; Sasazuki, Shizuka; Tsugane, Shoichiro

    2008-08-15

    The impact of total physical activity level on cancer risk has not been fully clarified, particularly in non-Western, relatively lean populations. The authors prospectively examined the association between daily total physical activity (using a metabolic equivalents/day score) and subsequent cancer risk in the Japan Public Health Center-based Prospective Study. A total of 79,771 general-population Japanese men and women aged 45-74 years who responded to a questionnaire in 1995-1999 were followed for total cancer incidence (4,334 cases) through 2004. Compared with subjects in the lowest quartile, increased daily physical activity was associated with a significantly decreased risk of cancer in both sexes. In men, hazard ratios for the second, third, and highest quartiles were 1.00 (95% confidence interval (CI): 0.90, 1.11), 0.96 (95% CI: 0.86, 1.07), and 0.87 (95% CI: 0.78, 0.96), respectively (p for trend = 0.005); in women, hazard ratios were 0.93 (95% CI: 0.82, 1.05), 0.84 (95% CI: 0.73, 0.96), and 0.84 (95% CI: 0.73, 0.97), respectively (p for trend = 0.007). The decreased risk was more clearly observed in women than in men, especially among the elderly and those who regularly engaged in leisure-time sports or physical exercise. By site, decreased risks were observed for cancers of the colon, liver, and pancreas in men and for cancer of the stomach in women. Increased daily physical activity may be beneficial in preventing cancer in a relatively lean population.

  15. Serum level modifications of female sex hormones after radiocastration with different total doses

    International Nuclear Information System (INIS)

    Naujokat, B.; Rohloff, R.; Willich, N.; Eiermann, W.

    1988-01-01

    We determined serum level of estradiol, FSH and LH over a period of six to eight weeks after ovarian irradiation for castration with different doses (2x2.5 Gy/3x2.5 Gy/4x2.5 Gy) in 15 patients with metastatic breast cancer as compared to changes after ovarectomy in five patients. The time course of the changing estradiol-, FSH and LH-serum levels sigificantly depends on the ovarian dose. After radiological castration with a dose of 4x2.5 Gy = 10 Gy in four days the estrogen levels decrease within two to three weeks, and the FSH- and LH-levels increase after three to four weeks into the postmenopausal range. Therefore, the time course is not very different from changes after ovarectomy. (orig.) [de

  16. Level of response to telematic questionnaires on Health Related Quality of Life on total knee replacement.

    Science.gov (United States)

    Besalduch-Balaguer, M; Aguilera-Roig, X; Urrútia-Cuchí, G; Puntonet-Bruch, A; Jordan-Sales, M; González-Osuna, A; Celaya-Ibáñez, F; Colomina-Morales, J

    2015-01-01

    Questionnaires measuring health-related quality of life are difficult to perform and obtain for patients and professionals. Computerised tools are now available to collect this information. The objective of this study was to assess the ability of patients undergoing total knee replacement to fill in health-related quality-of-life questionnaires using a telematic platform. Ninety eight consecutive patients undergoing total knee arthroplasty were included. Participants were given an access code to enter the website where they had to respond to 2 questionnaires (SF8 and the reduced WOMAC), and 3 additional questions about the difficulty in completing the questionnaires. A total of 98 patients agreed to participate: 45 males and 53 females (mean age 72.7 years). Fourteen did not agree to participate due to lack of internet access. Of the final 84 participants, 50% entered the website, and only 36 answered all questions correctly. Of the patients who answered the questionnaire, 80% were helped by a relative or friend, and 22% reported difficulty accessing internet. The use of telematic systems to respond to health-related quality of life questionnaires should be used cautiously, especially in elderly population. It is likely that the population they are directed at is not prepared to use this type of technology. Therefore, before designing telematics questionnaires it must be ensured that they are completed properly. Copyright © 2014 SECOT. Published by Elsevier Espana. All rights reserved.

  17. Total matrix metalloproteinase-8 serum levels in patients labouring preterm and patients with threatened preterm delivery.

    Directory of Open Access Journals (Sweden)

    Piotr Laudański

    2010-11-01

    Full Text Available Preterm labour and prematurity are still a main cause of perinatal morbidity nowadays. The aim of our study was to assess the role of MMP-8 as a predictive marker of preterm delivery. Four groups of patients were involved to the study: I - pregnant women at 24-34 weeks of gestation with any symptoms of threatened preterm labour; II - threatened preterm labour patients between 24-34 weeks of gestation; III - preterm vaginal delivery patients; IV - healthy term vaginal delivery patients. Serum concentration of total MMP-8 was measured using two enzyme-linked immunosorbent assays. There were no significant differences in the median concentrations of total MMP-8 between physiological pregnancy and threatened preterm labour patients with existing uterine contractility. No significant differences of total MMP-8 were either found between healthy term and preterm labouring patients. The studies on a larger population are needed to reject the hypothesis that preterm labour is connected with increased MMP-8 plasma concentrations of women in preterm labour and threatened preterm delivery.

  18. Do different types of bearings and noise from total hip arthroplasty influence hip-related pain, function, and quality of life postoperatively?

    DEFF Research Database (Denmark)

    Varnum, Claus; Pedersen, Alma B; Kjærsgaard-Andersen, Per

    2016-01-01

    with metal-on-metal (MoM) THAs to scores from patients with metal-on-polyethylene (MoP) THAs, and to determine the influence of THA-related noise on PROM scores. Patients and methods - We conducted a nationwide cross-sectional questionnaire survey in a cohort of patients identified from the Danish Hip......, and 12% with MoP THAs reported noise from their hip. For the 3 types of bearings, PROM scores from patients with a noisy THA were statistically significantly worse than those from patients with a silent MoP THA. The exception was noisy CoC and MoM THAs, which had the same mean UCLA activity score...

  19. Completion of Level 4 Milestone M4AT-15OR2301039 for the Johnson Noise Thermometry for Drift-free Temperature Measurements Work Package AT-15OR230103

    Energy Technology Data Exchange (ETDEWEB)

    Britton Jr, Charles L. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2015-09-14

    This memorandum constitutes our September 2015 level 4 milestone for the project entitled “Johnson Noise Thermometry for Drift-free Temperature Measurements” and satisfies the Milestone/Activity (Conclude HFIR field demonstration of JNT prototype). The progress summary describes the work performed to complete the subject milestone.

  20. Effect of total lymphoid irradiation on levels of serum autoantibodies in systemic lupus erythematosus and in rheumatoid arthritis

    International Nuclear Information System (INIS)

    Tanay, A.; Schiffman, G.; Strober, S.

    1986-01-01

    The effects of total lymphoid irradiation (TLI) on serum levels of autoantibodies, and of antibodies to diphtheria toxoid, tetanus toxoid, and pneumococcal polysaccharide in patients with lupus nephritis were compared with those previously observed in rheumatoid arthritis (RA) patients. Baseline levels of antibodies to diphtheria toxoid and tetanus toxoid decreased significantly after TLI in patients with lupus and RA, but antibody levels to pneumococcal polysaccharide remained unchanged. After TLI, the levels of antinuclear and anti-DNA antibodies were reduced significantly in lupus, but levels of rheumatoid factor, antinuclear, and antigranulocyte antibodies all tended to increase in RA

  1. Development and Validation of the Persian Version of the Acceptable Noise Level (ANL Test in Normal Children Aged 5-8 Years

    Directory of Open Access Journals (Sweden)

    Abdollah Moossavi

    2016-06-01

    Full Text Available Background: The goal of the present study was to develop and validate the Persian version of the Acceptable Noise Level (ANL test in normal, Persianspeaking children aged 5-8 years. Methods: This tool-making and non-experimental research was conducted in two stages. In the first stage the proper story was selected and recorded after evaluation of its content validity. In the second stage this test material was administered to a total 181 normal children (97 girls and 84 boys randomly chosen from the population of preschool and primary school children of Tehran (District 5, aged 5-8 years in four age groups to evaluate the reliability of test in order to develop the Persian version of the ANL test and assess its changes during the growth. Lawshe’s method and Cronbach’s alpha coefficient were used to assess the content validity and reliability of the test, respectively. Mann– Whitney U test was used to examine gender differences, and Kruskal-Wallis test was to examine age differences. Results: Test-retest correlation of 0.74 indicated acceptable reliability of the test. Significant differences were found between most of different age groups for the ANL mean scores (P0.05. Conclusion: The study results indicated good validity and reliability of the Persian version of the ANL test in children. Therefore this test can be useful in designing classrooms suitable for 5-8 year-old children of both genders.

  2. Effects of a traffic noise background on judgements of aircraft noise

    Science.gov (United States)

    Powell, C. A.; Rice, C. G.

    1974-01-01

    A study was conducted in which subjects judged aircraft noises in the presence of road traffic background noise. Two different techniques for presenting the background noises were evaluated. For one technique, the background noise was continuous over the whole of a test session. For the other, the background noise was changed with each aircraft noise. A range of aircraft noise levels and traffic noise levels were presented to simulate typical indoor levels.

  3. Trichromatic π-Pulse for Ultrafast Total Inversion of a Four-Level Ladder System

    Directory of Open Access Journals (Sweden)

    Carles Serrat

    2015-11-01

    Full Text Available We present a numerical solution for complete population inversion in a four-level ladder system obtained by using a full π-pulse illumination scheme with resonant ultrashort phase-locked Gaussian laser pulses. We find that a set of pulse areas such as √3π , √2π , and √3π completely inverts the four-level system considering identical effective dipole coupling coefficients. The solution is consistent provided the involved electric fields are not too strong and it is amply accurate also in the case of diverse transition dipole moments. We study the effect of detuning and chirp of the laser pulses on the complete population inversion using the level structure of atomic sodium interacting with ps and fs pulses as an example. Our result opens the door for multiple applications such as efficient ultrashort pulse lasing in the UV or the engineering of quantum states for quantum computing.

  4. Active Noise Control for Dishwasher noise

    Science.gov (United States)

    Lee, Nokhaeng; Park, Youngjin

    2016-09-01

    The dishwasher is a useful home appliance and continually used for automatically washing dishes. It's commonly placed in the kitchen with built-in style for practicality and better use of space. In this environment, people are easily exposed to dishwasher noise, so it is an important issue for the consumers, especially for the people living in open and narrow space. Recently, the sound power levels of the noise are about 40 - 50 dBA. It could be achieved by removal of noise sources and passive means of insulating acoustical path. For more reduction, such a quiet mode with the lower speed of cycle has been introduced, but this deteriorates the washing capacity. Under this background, we propose active noise control for dishwasher noise. It is observed that the noise is propagating mainly from the lower part of the front side. Control speakers are placed in the part for the collocation. Observation part of estimating sound field distribution and control part of generating the anti-noise are designed for active noise control. Simulation result shows proposed active noise control scheme could have a potential application for dishwasher noise reduction.

  5. Noise adaptation in integrate-and fire neurons.

    Science.gov (United States)

    Rudd, M E; Brown, L G

    1997-07-01

    The statistical spiking response of an ensemble of identically prepared stochastic integrate-and-fire neurons to a rectangular input current plus gaussian white noise is analyzed. It is shown that, on average, integrate-and-fire neurons adapt to the root-mean-square noise level of their input. This phenomenon is referred to as noise adaptation. Noise adaptation is characterized by a decrease in the average neural firing rate and an accompanying decrease in the average value of the generator potential, both of which can be attributed to noise-induced resets of the generator potential mediated by the integrate-and-fire mechanism. A quantitative theory of noise adaptation in stochastic integrate-and-fire neurons is developed. It is shown that integrate-and-fire neurons, on average, produce transient spiking activity whenever there is an increase in the level of their input noise. This transient noise response is either reduced or eliminated over time, depending on the parameters of the model neuron. Analytical methods are used to prove that nonleaky integrate-and-fire neurons totally adapt to any constant input noise level, in the sense that their asymptotic spiking rates are independent of the magnitude of their input noise. For leaky integrate-and-fire neurons, the long-run noise adaptation is not total, but the response to noise is partially eliminated. Expressions for the probability density function of the generator potential and the first two moments of the potential distribution are derived for the particular case of a nonleaky neuron driven by gaussian white noise of mean zero and constant variance. The functional significance of noise adaptation for the performance of networks comprising integrate-and-fire neurons is discussed.

  6. Association Of Serum Total Bilirubin Level With Diabetic Retinopathy In Type 2 Diabetes Mellitus.

    Science.gov (United States)

    Ghaffar, Tahir; Marwat, Zahid Irfan; Ullah, Fahim; Khan, Salman; Hassan Aamir, Aziz Ul

    2016-01-01

    Serum bilirubin has anti-inflammatory, antioxidant and immunological properties. It is considered a protective substance against atherosclerotic and microvascular complications of diabetes mellitus (DM). This study was designed to find the association between total serum bilirubin concentration and diabetic retinopathy (DR). This case control study was conducted in the Department of Endocrinology, Diabetes and Metabolic Diseases, Hayatabad Medical Complex, Peshawar. Type-2 DM patients more than 18 years of age of either gender with duration of T2DM more than 6 months were included and sub categorized in two groups. Cases (DM with DR) and Controls (DM without DR) while patients with acute and chronic liver diseases, haemolytic anaemia, history of chronic alcohol consumption, use of hepatotoxic drugs (anti-tuberculous, anti-epileptic), women on oral contraceptive pills were excluded. All participants underwent ophthalmic examination at diabetic retinopathy screening clinic followed by pre designed set of investigations. A total of 152 patients, 76 cases and 76 controls were included. Serum bilirubin concentration was found inversely and independently (p 0.000) associated and inversely co related (r -0.345and p 0.000) with prevalence of DR. Cases were concentrated in the lower quartiles of serum bilirubin concentration and vice versa. Low haemoglobin (p 0.00) and longer duration of DM (0.003) were independently and directly associated with prevalence of DR. Serum bilirubin concentration is inversely and independently associated and inversely correlated with the prevalence of DR and may predict progression of DR over time.

  7. Elevated levels of numerous cytokines in drainage fluid after primary total hip arthroplasty.

    NARCIS (Netherlands)

    Heide, H.J. van der; Kraan, P.M. van der; Rijnberg, W.J.; Buma, P.; Schreurs, B.W.

    2010-01-01

    As cytokines are involved in wound healing and other inflammatory processes, it could be valuable to measure their levels at the operative site. This study was conducted to investigate whether different cytokines are measurable in drainage fluid and, when measurable, whether we can find a difference

  8. Total serum IgE level influences oral food challenge tests for IgE-mediated food allergies.

    Science.gov (United States)

    Horimukai, K; Hayashi, K; Tsumura, Y; Nomura, I; Narita, M; Ohya, Y; Saito, H; Matsumoto, K

    2015-03-01

    Probability curves predicting oral food challenge test (OFC) results based on specific IgE levels are widely used to prevent serious allergic reactions. Although several confounding factors are known to affect probability curves, the main factors that affect OFC outcomes are currently unclear. We hypothesized that an increased total IgE level would reduce allergic reactivity. Medical records of 337 and 266 patients who underwent OFCs for 3.5 g boiled hen's egg white and 3.1 ml raw cow's milk, respectively, were examined retrospectively. We subdivided the patients into three groups based on total IgE levels and age by percentile (75th percentiles), and logistic regression analyses were performed on each group. Patients with higher total IgE levels were significantly less responsive. In addition, age did not significantly affect the OFC results. Therefore, total IgE levels should be taken into account when predicting OFC results based on food-specific IgE levels. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  9. Effect of dietary poly unsaturated fatty acids on total brain lipid concentration and anxiety levels of electron beam irradiated mice

    International Nuclear Information System (INIS)

    Suchetha Kumari; Bekal, Mahesh

    2013-01-01

    The whole brain irradiation causes injury to the nervous system at various levels. Omega-3 poly unsaturated fatty acids are very much essential for the growth and development of nervous system. Dietary supplementation of these nutrients will promote the development of injured neuronal cells. Therefore this study was undertaken to establish the role of Omega-3 poly unsaturated fatty acids on total brain lipid concentration, lipid peroxidation and anxiety levels in the irradiated mice. The effect of Electron Beam Radiation (EBR) on total brain lipid concentration, lipid peroxidation and anxiety level were investigated in male Swiss albino mice. The study groups were subjected to a sub-lethal dose of EBR and also the flax seed extract and fish oil were given orally to the irradiated mice. Irradiated groups show significant elevation in anxiety levels when compared to control group, indicating the acute radiation effects on the central nervous system. But the oral supplementation of dietary PUFA source decrees the anxiety level in the irradiated group. The analysis of lipid peroxidation showed a significant level of changes when compared between control and radiation groups. Dietary PUFA supplementation showed a significant level of decrease in the lipid peroxidation in the irradiated groups. The observation of total lipids in brain shows decrease in concentration in the irradiated groups, the differences in the variables follow the similar patterns as of that the MDA levels. This study suggests that the dietary intake of PUFAs may help in prevention and recovery of the oxidative stress caused by radiation. (author)

  10. Aloe vera extract reduces 8-oxo-2'-deoxyguanosine levels and improves total antioxidants in streptozotocin-induced diabetic rats

    Directory of Open Access Journals (Sweden)

    Wulan Christijanti

    2017-04-01

    Full Text Available Background Diabetes mellitus is a chronic disease caused by lack of insulin production in the pancreas or by insulin resistance, the disease being characterized by elevated blood glucose levels. Hyperglycemia in diabetes could lead to oxidative stress due to the rise in 8-oxo-2'-deoxyguanosine (8-oxo-dG levels and the decrease in levels of total antioxidant status (TAS. The purpose of this study was to assess the effect Aloe vera extract on 8-oxo-dG level and total antioxidant status in diabetic rat testis.   Methods This was an experimental laboratory study with 20 rat samples which were divided into 4 groups (1 control group and 3 treatment groups. Diabetes was induced in the rats by streptozotocin (STZ at 65 mg/kgBW. The diabetic rats were then treated for 28 days with Aloe vera extract at 0 mg (P0, 200 mg rind (P1, 200 mg pulp (P2, respectively. The level of 8 -oxo-dG was measured by ELISA and total antioxidant status with 2,2' -azino-bis (3-ethylbenzothiazoline-6-sulfonic acid (ABTS. Data were analyzed with ANOVA and Least Significant Difference Advanced Test at P<0.05.   Results 8-Oxo-dG levels were significantly different between the control group and both P0 and P2, but not between the control group and P1. Among the treatment groups the 8-oxo-dG levels were significantly different. Mean total antioxidant status was significantly different between control and treatment groups, and also between treatment groups (p<0.05.   Conclusions Aloe vera extract reduced free radicals (level of 8-oxo-dG and increased the total antioxidant status in diabetic rat testis.

  11. Noise suppression in duct

    International Nuclear Information System (INIS)

    Ahmed, A.; Barfeh, M.A.G.

    2001-01-01

    In air-conditioning system the noise generated by supply fan is carried by conditioned air through the ductwork. The noise created in ductwork run may be transmission, regenerative and ductborne. Transmission noise is fan noise, regenerative noise is due to turbulence in flow and ductborne noise is the noise radiating from duct to surroundings. Some noise is attenuated in ducts also but if noise level is high then it needs to be attenuated. A simple mitre bend can attenuate-noise. This principle is extended to V and M-shape ducts with inside lining of fibreglass, which gave maximum attenuation of 77 dB and 62 dB respectively corresponding to 8 kHz frequency as compared to mitre, bend giving maximum 18 dB attenuation. Sound level meter measured sound levels with octave band filter and tests were conducted in anechoic room. A V-shape attenuator can be used at fan outlet and high frequency noise can be minimized greatly. (author)

  12. Association of serum total bilirubin level with diabetic retinopathy in type 2 diabetes mellitus

    International Nuclear Information System (INIS)

    Ghaffar, T.; Khan, S.; Aamir, A.U.H.; Marwat, Z.I.

    2016-01-01

    Serum bilirubin has anti-inflammatory, antioxidant and immunological properties. It is considered a protective substance against atherosclerotic and microvascular complications of diabetes mellitus (DM). This study was designed to find the association between total serum bilirubin concentration and diabetic retinopathy (DR). Methods: This case control study was conducted in the Department of Endocrinology, Diabetes and Metabolic Diseases, Hayatabad Medical Complex, Peshawar. Type-2 DM patients more than 18 years of age of either gender with duration of T2DM more than 6 months were included and sub categorized in two groups. Cases (DM with DR) and Controls (DM without DR) while patients with acute and chronic liver diseases, haemolytic anaemia, history of chronic alcohol consumption, use of hepatotoxic drugs (anti-tuberculous, anti-epileptic), women on oral contraceptive pills were excluded. All participants underwent ophthalmic examination at diabetic retinopathy screening clinic followed by pre designed set of investigations. Results: A total of 152 patients, 76 cases and 76 controls were included. Serum bilirubin concentration was found inversely and independently (p 0.000) associated and inversely co related (r -0.345 and p 0.000) with prevalence of DR. Cases were concentrated in the lower quartiles of serum bilirubin concentration and vice versa. Low haemoglobin (p 0.00) and longer duration of DM (0.003) were independently and directly associated with prevalence of DR. Conclusion: Serum bilirubin concentration is inversely and independently associated and inversely correlated with the prevalence of DR and may predict progression of DR over time. (author)

  13. Critical Low-Noise Technologies Being Developed for Engine Noise Reduction Systems Subproject

    Science.gov (United States)

    Grady, Joseph E.; Civinskas, Kestutis C.

    2004-01-01

    NASA's previous Advanced Subsonic Technology (AST) Noise Reduction Program delivered the initial technologies for meeting a 10-year goal of a 10-dB reduction in total aircraft system noise. Technology Readiness Levels achieved for the engine-noise-reduction technologies ranged from 4 (rig scale) to 6 (engine demonstration). The current Quiet Aircraft Technology (QAT) project is building on those AST accomplishments to achieve the additional noise reduction needed to meet the Aerospace Technology Enterprise's 10-year goal, again validated through a combination of laboratory rig and engine demonstration tests. In order to meet the Aerospace Technology Enterprise goal for future aircraft of a 50- reduction in the perceived noise level, reductions of 4 dB are needed in both fan and jet noise. The primary objectives of the Engine Noise Reduction Systems (ENRS) subproject are, therefore, to develop technologies to reduce both fan and jet noise by 4 dB, to demonstrate these technologies in engine tests, and to develop and experimentally validate Computational Aero Acoustics (CAA) computer codes that will improve our ability to predict engine noise.

  14. Combat aircraft noise

    Science.gov (United States)

    Sgarbozza, M.; Depitre, A.

    1992-04-01

    A discussion of the characteristics and the noise levels of combat aircraft and of a transport aircraft in taking off and landing are presented. Some methods of noise reduction are discussed, including the following: operational anti-noise procedures; and concepts of future engines (silent post-combustion and variable cycle). Some measurement results concerning the noise generated in flight at great speeds and low altitude will also be examined. Finally, the protection of the environment of French air bases against noise will be described and the possibilities of regulation examined.

  15. Effect of training data size and noise level on support vector machines virtual screening of genotoxic compounds from large compound libraries.

    Science.gov (United States)

    Kumar, Pankaj; Ma, Xiaohua; Liu, Xianghui; Jia, Jia; Bucong, Han; Xue, Ying; Li, Ze Rong; Yang, Sheng Yong; Wei, Yu Quan; Chen, Yu Zong

    2011-05-01

    Various in vitro and in-silico methods have been used for drug genotoxicity tests, which show limited genotoxicity (GT+) and non-genotoxicity (GT-) identification rates. New methods and combinatorial approaches have been explored for enhanced collective identification capability. The rates of in-silco methods may be further improved by significantly diversified training data enriched by the large number of recently reported GT+ and GT- compounds, but a major concern is the increased noise levels arising from high false-positive rates of in vitro data. In this work, we evaluated the effect of training data size and noise level on the performance of support vector machines (SVM) method known to tolerate high noise levels in training data. Two SVMs of different diversity/noise levels were developed and tested. H-SVM trained by higher diversity higher noise data (GT+ in any in vivo or in vitro test) outperforms L-SVM trained by lower noise lower diversity data (GT+ in in vivo or Ames test only). H-SVM trained by 4,763 GT+ compounds reported before 2008 and 8,232 GT- compounds excluding clinical trial drugs correctly identified 81.6% of the 38 GT+ compounds reported since 2008, predicted 83.1% of the 2,008 clinical trial drugs as GT-, and 23.96% of 168 K MDDR and 27.23% of 17.86M PubChem compounds as GT+. These are comparable to the 43.1-51.9% GT+ and 75-93% GT- rates of existing in-silico methods, 58.8% GT+ and 79% GT- rates of Ames method, and the estimated percentages of 23% in vivo and 31-33% in vitro GT+ compounds in the "universe of chemicals". There is a substantial level of agreement between H-SVM and L-SVM predicted GT+ and GT- MDDR compounds and the prediction from TOPKAT. SVM showed good potential in identifying GT+ compounds from large compound libraries based on higher diversity and higher noise training data.

  16. White-crowned sparrow males show immediate flexibility in song amplitude but not in song minimum frequency in response to changes in noise levels in the field.

    Science.gov (United States)

    Derryberry, Elizabeth P; Gentry, Katherine; Derryberry, Graham E; Phillips, Jennifer N; Danner, Raymond M; Danner, Julie E; Luther, David A

    2017-07-01

    The soundscape acts as a selective agent on organisms that use acoustic signals to communicate. A number of studies document variation in structure, amplitude, or timing of signal production in correspondence with environmental noise levels thus supporting the hypothesis that organisms are changing their signaling behaviors to avoid masking. The time scale at which organisms respond is of particular interest. Signal structure may evolve across generations through processes such as cultural or genetic transmission. Individuals may also change their behavior during development (ontogenetic change) or in real time (i.e., immediate flexibility). These are not mutually exclusive mechanisms, and all must be investigated to understand how organisms respond to selection pressures from the soundscape. Previous work on white-crowned sparrows ( Zonotrichia leucophrys ) found that males holding territories in louder areas tend to sing higher frequency songs and that both noise levels and song frequency have increased over time (30 years) in urban areas. These previous findings suggest that songs are changing across generations; however, it is not known if this species also exhibits immediate flexibility. Here, we conducted an exploratory, observational study to ask whether males change the minimum frequency of their song in response to immediate changes in noise levels. We also ask whether males sing louder, as increased minimum frequency may be physiologically linked to producing sound at higher amplitudes, in response to immediate changes in environmental noise. We found that territorial males adjust song amplitude but not minimum frequency in response to changes in environmental noise levels. Our results suggest that males do not show immediate flexibility in song minimum frequency, although experimental manipulations are needed to test this hypothesis further. Our work highlights the need to investigate multiple mechanisms of adaptive response to soundscapes.

  17. Noise in the operating room

    DEFF Research Database (Denmark)

    Hasfeldt-Hansen, Dorthe; Lærkner, Eva Ann; Birkelund, Regner

    2010-01-01

    Because noise is a general stressor, noise in the OR should be avoided whenever possible. This article presents the results of a review of the research literature on the topic of noise in the OR. A systematic literature search was conducted. Eighteen relevant articles were identified...... and categorized as follows: noise levels, noise sources, staff performances, and patient’s perception of noise. Each study was assessed according to the strength of the evidence and the quality of the study. Noise levels in the OR in general exceed recommended levels, and the noise sources are related...... to equipment and staff behavior. The main effect of noise on staff performances is related to impaired communication, resulting in a negative effect on patient safety. The literature on patients’ perception of noise is both limited and inconsistent, and more research on this topic is needed....

  18. Reduction in total plasma ghrelin levels following catecholamine depletion: relation to bulimic and depressive symptoms.

    Science.gov (United States)

    Homan, Philipp; Grob, Simona; Milos, Gabriella; Schnyder, Ulrich; Hasler, Gregor

    2013-09-01

    There is increasing preclinical and clinical evidence of the important role played by the gastric peptide hormone ghrelin in the pathogenesis of symptoms of depression and eating disorders. To investigate the role of ghrelin and its considered counterpart, peptide tyrosine tyrosine (PYY), in the development of bulimic and depressive symptoms induced by catecholamine depletion, we administered the tyrosine hydroxylase inhibitor alpha-methyl-paratyrosine (AMPT) in a randomized, double-blind, placebo-controlled crossover, single-site experimental trial to 29 healthy controls and 20 subjects with fully recovered bulimia nervosa (rBN). We found a decrease between preprandial and postprandial plasma ghrelin levels (psymptoms (psymptoms induced by catecholamine depletion. These findings suggest a relationship between catecholamines and ghrelin with depressive symptoms. Copyright © 2013 Elsevier Ltd. All rights reserved.

  19. Liquid chromatography tandem mass spectrometry determination of total budesonide levels in dog plasma after inhalation exposure.

    Science.gov (United States)

    Berg, Seija; Melamies, Marika; Rajamäki, Minna; Vainio, Outi; Peltonen, Kimmo

    2012-01-01

    A sensitive and selective method to quantify budesonide in dog plasma samples was developed and fully validated. Liquid-liquid extraction was followed by solid-phase extraction and liquid chromatography-tandem mass spectrometry with electrospray ionization. After reconstitution of the analytes in the mobile phase, samples were analysed by reversed-phase liquid chromatography with isocratic elution. d8-Budesonide was used as an internal standard, and characteristic transitions of d8-budesonide and budesonide were used for quantification. The method was validated with respect to selectivity, specificity, linearity, recovery, repeatability, reproducibility and limits of detection and quantification. The validated method was successfully applied to monitor the plasma levels of budesonide in dogs exposed to clinical doses of inhaled and intravenous drug.

  20. Relationship between serum total bilirubin levels and mortality in uremia patients undergoing long-term hemodialysis: A nationwide cohort study.

    Science.gov (United States)

    Su, Hui-Hsien; Kao, Chia-Man; Lin, Yi-Chun; Lin, Yen-Chung; Kao, Chih-Chin; Chen, Hsi-Hsien; Hsu, Chih-Cheng; Chen, Kuan-Chou; Peng, Chiung-Chi; Wu, Mai-Szu

    2017-10-01

    Previous studies show that serum bilirubin has potent antioxidant effect and is associated with protection from kidney damage and reduce cardiovascular events. The aim of this study was to examine the association of serum total bilirubin level and mortality in uremia patients who underwent hemodialysis. This is a nationwide retrospective long-term cohort study. Patients were registered in the Taiwan Renal Registry Data System (TWRDS) from 2005 to 2012. A total of 115,535 hemodialysis patients were surveyed and those with valid baseline total bilirubin (TB) data were enrolled. All-cause mortality was the primary outcome. A total of 47,650 hemodialysis patients followed for 27.6 ± 12 months, were divided into 3 groups according to different baseline serum total bilirubin levels (0.1-0.3, 0.3-0.7, 0.7-1.2 mg/dL). Mean age was 61.4 ± 13.6 years, 50% were male, 13% were hepatitis B carriers, and 20% were hepatitis C carriers. Primary outcome was the 3-year mortality. The TB level 0.7-1.2 mg/dL group had high mortality, statistically significant hazard ratio of mortality was 1.14 (crude HR, 95% 1.07-1.20, p bilirubin on hemodialysis patients are needed. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. ENHANCEMENT OF NOISE LEVEL IN URBAN ENVIRONMENT DUE TOURIST ACTIVITIES: A CASE STUDY IN THE CITY OF CAMPOS DO JORDÃO

    Directory of Open Access Journals (Sweden)

    Luiz Antonio Brito

    2014-12-01

    Full Text Available The excess of noise in large cities is a recurrent situation which creates irritability, loss of efficiency at work and loss of life quality, in such way that the silence and the tranquility of smaller cities end up being a touristic appeal. But, at the same time, the touristic activities have great potential of generating noise energy, which leads to a conflicting situation. The city of Campos de Jordão, nationally known for its cool climate, European architecture and sophisticated gastronomy, is popular among people who seek both tranquility and entertainment. The objective of this assignment is to evaluate the urban impact created by the increase of noise energy due to touristic activities in the city of Campos do Jordão. Thus, measurement of sound pressure levels were carried out on holidays and working days in 15 chosen spots. The results showed a considerable elevation of noise levels, even in areas away from touristic zones. This condition tends to move hotels and inns away from the touristic zone of the city, which demands investments in infrastructure, burdening the local government.

  2. Comparative seric TGF(β1, β2) levels and platelets count response in total body irradiated baboons

    International Nuclear Information System (INIS)

    Mestries, J.C.; Veyret, J.; Agay, D.; Van Uye, A.; Caterini, R.; Herodin, F.; Mathieu, J.; Chancerelle, Y.

    1994-01-01

    Total body irradiation associated or not with r-hIL-6 treatment a relation between TGF-β1 and TGF-β2 blood levels and platelets count. During radio-induced thrombocytopenia, by decreasing its ability to inhibit proliferation of stem cells and megakaryocytopoiesis, the TGF-β falling induced a favorable condition for hematopoietic recovery. (author)

  3. Total testosterone levels are often more than three times elevated in patients with androgen-secreting tumours

    DEFF Research Database (Denmark)

    Glintborg, Dorte; Lambaa Altinok, Magda; Petersen, Kresten Rubeck

    2015-01-01

    surgery. Terminal hair growth on lip and chin gradually increases after menopause, which complicates distinction from normal physiological variation. Precise testosterone assays have just recently become available in the daily clinic. We present three women diagnosed with testosterone-producing tumours...... when total testosterone levels are above three times the upper reference limit....

  4. Quantitation of bilirubin conjugates with high-performance liquid chromatography in patients with low total serum bilirubin levels

    NARCIS (Netherlands)

    Jansen, P. L.; Cuypers, H. T.; Peters, W. H.

    1984-01-01

    Bilirubin mono- and diconjugates were determined by alkaline methanolysis and high-performance liquid chromatography (HPLC) in serum from patients with metastatic liver disease and liver cirrhosis. Conjugates could be detected and quantitated at normal or low total bilirubin levels. Comparison with

  5. Cost-Benefit Analysis of Rail-Noise Mitigation Programmes at European Level: Methodological Innovations from EURANO to STAIRRS

    OpenAIRE

    Aude Lenders; Nancy Da Silva; Walter Hecq; Baumgartner Thomas

    2001-01-01

    The STAIRRS project (2000-2002) is a follow-up of EURANO [1] and a Swiss study [2], in which the authors evaluated the efficiency of noise reduction measures in two European freight corridors. STAIRRS includes a cost-benefit analysis based on about 10,000 km of track modelled in seven countries. The benefits are defined in terms of the dB(A) experienced by those living in the rail corridors modelled. They are to be weighted by the number of persons benefiting each year from a noise reduction ...

  6. Assessment of serum selenium levels in 2-month-old sucking calves using total reflection technique

    International Nuclear Information System (INIS)

    Bernardini, D.; Testoni, S.; Buoso, M.C.; Ceccato, D.; Moschini, G.; Valdes, M.; Torboli, A.

    2000-01-01

    The assessment of selenium status of livestock is an important aspect of production medicine as evidence for the influence of low Se levels on disease resistance in ruminants is reviewed with emphasis on susceptibility to various pathologies (such as infections, exudative diathesis, pneumonia, pancreatic degeneration). Additional evidence suggests that Se deficiency may cause muscular dystrophy in calves, while, severe deficiency has been associated with cardiomyopathy and even death. Serum Se content is a good indicator of the short term Se status and reflects the recent dietary intake of the element. Since serum Se content is a good indicator of the short term status of the element and reflects the its recent dietary intake, the present work is aimed to determine Se concentration in serum from a group of 2 months old sucking calves suspected to be severely deficient. We used the TX 2000 X-ray spectrometer manufactured by Ital Structures. The energy resolution (FWHM) of the Si(Li) detector was 137 eV for Mn Kα. Among nuclear techniques the TXRF method is the best suitable for trace element analysis in liquid or dissolved samples and can deal much easier with elemental investigation. Physical basis of used analytical method, experimental set up and the sample preparation procedure are described. The concentration data obtained are presented and discussed. (author)

  7. Serum tree IGF-I, total IGF-I, IGFBP-1 and IGFBP-3 levels in an elderly population : relation to age and sex steroid levels

    NARCIS (Netherlands)

    Janssen, JAMJL; Stolk, RP; Pols, HAP; Grobbee, DE; de Jong, FH; Lamberts, SWJ

    BACKGROUND Most previous studies concerning the relationship between IGF-I and age used assays measuring total IGF-I, Although free IGF-I is considered of greater biological relevance, little is known about its relationship with sex steroids levels in elderly healthy subjects, MEASUREMENTS In a

  8. Quantification of the levels of tannins and total phenols and evaluation of the antioxidant activity of fruits of pepper tree

    Directory of Open Access Journals (Sweden)

    Natália Ribeiro Bernardes

    2011-12-01

    Full Text Available The fruits of pepper tree (Schinus terebinthifolius Raddi are widely used in the world cooking and its consumption has been encouraged since the late 80’s due to the presence of phenolic substances. Therefore, this study quantified the levels of tannins and total phenols in the fruits of pepper tree, aiming at establishing a possible correlation between these substances and their antioxidant activity. Phenolic compounds were extracted with acetone: water (7:3, and quantified by spectrophotometry. The antioxidant activity was measured by DPPH method. The results showed low levels of condensed tannins and total phenols in the peel of the fruit, not being detected hydrolysable tannins in them. Nevertheless, the methanolic extract showed high antioxidant potential, which indicates the absence of a correlation between antioxidant activity and the levels of phenolic compounds in these fruits.

  9. The community response to aircraft noise around six Spanish airports

    Science.gov (United States)

    Garcia, A.; Faus, L. J.; Garcia, A. M.

    1993-06-01

    The community response to aircraft noise has been studied through a social survey. A total of 1800 persons living in the vicinity of six major Spanish airports have been interviewed at their homes concerning the environmental quality of the area, dissatisfaction with road traffic noise and aircraft noise, activities interfered with by noise, most disturbing aircraft types, and subjective evaluation of airport impact. All the responses obtained in this survey have been compared with aircraft noise levels corresponding to the residence locations of the people interviewed (values of NEF levels were calculated with the INM model). The results obtained in this work allow one to evaluate the impact of aircraft noise under a wide range of different situations.

  10. Nível de ruídos em uma unidade de cuidados intensivos pediátricos Noise level in a pediatric intensive care unit

    Directory of Open Access Journals (Sweden)

    Werther B. Carvalho

    2005-12-01

    Full Text Available OBJETIVO: Verificar o nível de ruídos em uma unidade de cuidados intensivos pediátricos. MÉTODOS: Estudo observacional e prospectivo realizado em uma unidade de cuidados intensivos pediátricos de 10 leitos de um hospital universitário da cidade de São Paulo, Brasil. Os níveis de ruídos foram medidos por meio de equipamento instalado no corredor de acesso à unidade de cuidados intensivos pediátricos, posto de enfermagem, duas salas com três e cinco leitos, bem como nas unidades de isolamento. O equipamento utilizado foi calibrado para registrar a pressão do som em dBA, durante 24 horas, por 6 dias. Os dados foram analisados de acordo com as curvas gráficas registradas pelo equipamento. RESULTADOS: Foi identificado um nível basal de ruídos de 60 a 70 dBA, com pico de 120 dBA. Os níveis mais elevados foram identificados no período diurno, decorrentes da atividade e comunicação dos profissionais. CONCLUSÃO: Os níveis de ruídos identificados excederam as recomendações do International Noise Council, da Organização Mundial da Saúde. A educação sobre os efeitos prejudiciais de ruídos na audição humana e sua relação com o estresse constituem as bases para a implementação de programas de redução de ruídos.OBJECTIVE: The purpose of this study was to verify the noise level at a PICU. METHODS: This prospective observational study was performed in a 10 bed PICU at a teaching hospital located in a densely populated district within the city of São Paulo, Brazil. Sound pressure levels (dBA were measured 24 hours during a 6-day period. Noise recording equipment was placed in the PICU access corridor, nursing station, two open wards with three and five beds, and in isolation rooms. The resulting curves were analyzed. RESULTS: A basal noise level variation between 60 and 70 dBA was identified, with a maximum level of 120 dBA. The most significant noise levels were recorded during the day and were produced by the staff

  11. Aerodynamical noise from wind turbine generators

    International Nuclear Information System (INIS)

    Jakobsen, J.; Andersen, B.

    1993-06-01

    Two extensive measurement series of noise from wind turbines have been made during different modifications of their rotors. One series focused on the influence from the tip shape on the noise, while the other series dealt with the influence from the trailing edge. The experimental layout for the two investigations was identical. The total A-weighted noise from the wind turbine was measured in 1/3 octave bands from 50 Hz to 10 kHz in 1-minute periods simultaneously with wind speed measurements. The microphone was mounted on a hard board on the ground about 40 m directly downwind of the wind turbine, and the wind speed meter was placed at the same distance upwind of the wind turbine 10 m above ground. Regression analysis was made between noise and wind speed in each 1/3 octave band to determine the spectrum at 8 m/s. During the measurements care was taken to avoid influence from background noise, and the influence from machinery noise was minimized and corrected for. Thus the results display the aerodynamic rotor noise from the wind turbines. By use of this measurement technique, the uncertainty has been reduced to 1.5 - 2 dB per 1/3 octave band in the relevant frequency range and to about 1 dB on the total A-weighted levels. (au) (10 refs.)

  12. [Serum total cholesterol levels and eligibility for long-term care insurance: a prospective cohort study of the Tsurugaya project].

    Science.gov (United States)

    Hoshi, Rena; Tomata, Yasutake; Kakizaki, Masako; Tsuboya, Toru; Nagai, Masato; Watanabe, Ikue; Hozawa, Atsushi; Tsuji, Ichiro

    2013-08-01

    The purpose of this study was to examine the relationship between serum total cholesterol levels and certification eligibility for long-term care insurance in elderly Japanese individuals. The Tsurugaya Project was a comprehensive geriatric assessment conducted for community-dwelling elderly individuals aged ≥70 years in the Tsurugaya area, Sendai, Japan. Of the 2,925 inhabitants, 958 subjects participated in the Tsurugaya Project. For this analysis, we used 827 subjects who gave informed consent and were not qualified for long-term care insurance at the time of the baseline survey. Subjects were followed up for 6 years. We classified the subjects into 4 quintiles and used the fourth quintile (212-230 mg/dL) as a reference for statistical analysis. We used Cox proportional hazards model to estimate the hazard ratios (HRs) and 95% confidence intervals (CIs) of certification eligibility for long-term care insurance according to total cholesterol levels in serum. During 6 years of follow-up, a total of 214 subjects were qualified for long-term care insurance certification. The lowest serum total cholesterol level (care insurance certification. Compared with the fourth quintile, multivariate HRs (95%CIs) of long-term care insurance certification were 1.91 (1.23-2.98), 1.36 (0.85-2.18), 0.99 (0.62-1.56), 1.38 (0.88-2.17), for total cholesterol levels were significantly associated with increased eligibility for long-term care insurance certification even after adjusting for a variety of confounding factors.

  13. Effect of cold storage on total phenolics content, antioxidant activity and vitamin C level of selected potato clones.

    Science.gov (United States)

    Külen, Oktay; Stushnoff, Cecil; Holm, David G

    2013-08-15

    Twelve Colorado-grown specialty potato clones were evaluated for total phenolic content, antioxidant activity and ascorbic acid content at harvest and after 2, 4, 6 and 7 months cold storage at 4 °C. Potato clones were categorized as pigmented ('CO97226-2R/R', 'CO99364-3R/R', 'CO97215-2P/P', 'CO97216-3P/P', 'CO97227-2P/P', 'CO97222-1R/R', 'Purple Majesty', 'Mountain Rose' and 'All Blue'), yellow ('Yukon Gold') and white fleshed ('Russet Nugget', 'Russet Burbank'). Folin-Ciocalteu reagent was used to estimate total phenolic content, and 2,2'-azino-bis(3-ethylbenzothiazoline-6-sulfonic acid) diammonium salt (ABTS(•+) ) and 2,2-diphenyl-1-picrylhydrazyl (DPPH(•) ) radical scavenging assays were used to estimate antioxidant capacity. Pigmented potato genotypes had significantly higher total phenolic content and antioxidant activity at all data points than yellow- and white-fleshed cultivars. Vitamin C content was higher in 'Yukon Gold' than in the other clones. The highest level of vitamin C in all clones was at harvest and after 2 months in cold storage. Vitamin C content in all potato clones dropped rapidly with longer intervals of cold storage. Although total phenolic content and antioxidant activity fluctuated during cold storage, after 7 months of cold storage their levels were slightly higher than at harvest. Total phenolic content was better correlated with Trolox equivalent antioxidant capacity (TEAC)/ABTS(•+) than the TEAC/DPPH(•) radical scavenging assay. Pigmented potato clones had significantly higher total phenolic content and antioxidant activity, while the yellow-fleshed potato cultivar 'Yukon Gold' had significantly higher vitamin C content. Vitamin C content decreased in all potato clones during cold storage, while total phenolics increased in pigmented clones. © 2013 Society of Chemical Industry.

  14. Managing Electrochemical Noise Data by Exception Application of an On Line EN Data Analysis Technique to Data From a High Level Nuclear Waste Tank

    International Nuclear Information System (INIS)

    EDGEMON, G.L.

    2003-01-01

    Electrochemical noise has been used a t the Hanford Site for a number of years to monitor in real time for pitting corrosion and stress corrosion cracking (SCC) mechanisms in high level nuclear waste tanks. Currently the monitoring technique has only been implemented on three of the 177 underground storage tanks on the site. Widespread implementation of the technique has been held back for of a number of reasons, including issues around managing the large volume of data associated with electrochemical noise and the complexity of data analysis. Expert review of raw current and potential measurements is the primary form of data analysis currently used at the Hanford site. This paper demonstrates the application of an on-line data filtering and analysis technique that could allow data from field applications of electrochemical noise to be managed by exception, transforming electrochemical noise data into a process parameter and focusing data analysis efforts on the important data. Results of the analysis demonstrate a data compression rate of 95%; that is, only 5% of the data would require expert analysis if such a technique were implemented. It is also demonstrated that this technique is capable of identifying key periods where localized corrosion activity is apparent

  15. Serum anti-Müllerian hormone, inhibin B, and total inhibin levels in women with hypothalamic amenorrhea and anorexia nervosa.

    Science.gov (United States)

    Luisi, Stefano; Ciani, Valentina; Podfigurna-Stopa, Agnieszka; Lazzeri, Lucia; De Pascalis, Flavio; Meczekalski, Blazej; Petraglia, Felice

    2012-01-01

    To evaluate whether neuroendocrine forms of secondary amenorrhea (hypothalamic nervosa (HA) and anorexia nervosa (AN)) affect serum anti-Müllerian hormone (AMH), inhibin B, and total inhibin levels. Amenorrheic women (n = 82) (aged between 16 and 35 years old) according to diagnosed with neuroendocrine forms of amenorrhea: HA (n = 64), AN (n = 18), and healthy women (n = 41) (control group) were enrolled. Serum AMH, inhibin B, and total inhibin levels were measured by specific ELISA. No statistically significant difference of AMH serum levels between women with HA, AN, and control group was observed. Serum inhibin B and total inhibin levels in women with HA (p < 0.0001), AN (p < 0.05) resulted significantly lower than in control healthy women. The present data showed that neuroendocrine forms of amenorrhea are associated with an impaired inhibin secretion while not AMH. These data indirectly support that AMH is an excellent marker of ovarian reserve and its secretion is not influenced by the hypothalamic-ovarian axis activity.

  16. Effect of culture levels, ultrafiltered retentate addition, total solid levels and heat treatments on quality improvement of buffalo milk plain set yoghurt.

    Science.gov (United States)

    Yadav, Vijesh; Gupta, Vijay Kumar; Meena, Ganga Sahay

    2018-05-01

    Studied the effect of culture (2, 2.5 and 3%), ultrafiltered (UF) retentate addition (0, 11, 18%), total milk solids (13, 13.50, 14%) and heat treatments (80 and 85 °C/30 min) on the change in pH and titratable acidity (TA), sensory scores and rheological parameters of yoghurt. With 3% culture levels, the required TA (0.90% LA) was achieved in minimum 6 h incubation. With an increase in UF retentate addition, there was observed a highly significant decrease in overall acceptability, body and texture and colour and appearance scores, but there was highly significant increase in rheological parameters of yoghurt samples. Yoghurt made from even 13.75% total solids containing nil UF retentate was observed to be sufficiently firm by the sensory panel. Most of the sensory attributes of yoghurt made with 13.50% total solids were significantly better than yoghurt prepared with either 13 or 14% total solids. Standardised milk heated to 85 °C/30 min resulted in significantly better overall acceptability in yoghurt. Overall acceptability of optimised yoghurt was significantly better than a branded market sample. UF retentate addition adversely affected yoghurt quality, whereas optimization of culture levels, totals milk solids and others process parameters noticeably improved the quality of plain set yoghurt with a shelf life of 15 days at 4 °C.

  17. The relationship between serum total testosterone and free testosterone levels with serum hemoglobin and hematocrit levels: a study in 1221 men.

    Science.gov (United States)

    Shin, Yu Seob; You, Jae Hyung; Cha, Jai Seong; Park, Jong Kwan

    2016-12-01

    To investigate the relationship between serum total testosterone (TT) and free testosterone (FT) levels in men with anemia. We reviewed the records of 1221 subjects between March 2009 and December 2014. All the subjects' blood samples were drawn for TT and FT assays. Their serum hemoglobin (Hb) and serum hematocrit (Hct) levels were measured. The primary objective of our study was to investigate the association between TT and FT levels with Hb and Hct levels. The mean age was 59.82 ± 12.71 years. The mean TT and FT levels were 4.54 ± 2.02 ng/mL and 10.63 ± 3.69 pg/mL, respectively. The mean Hb and Hct levels were 14.72 ± 1.34 g/dL and 43.11 ± 3.75%, respectively. Subjects with low TT (<2.35 ng/mL) had low Hb and Hct levels (p < 0.001, p < 0.001, respectively). TT was positively associated with FT, Hb, and Hct. TT and FT levels were significantly lower in older men. Subjects with low TT and FT levels had low Hb and Hct levels. This suggests that TT and FT play a significant role in erythropoiesis. Testosterone replacement therapy may be effective in men with hypogonadism to reduce the incidence of anemia.

  18. Intensidade de ruído em hospital de 222 leitos na 18ª Regional de Saúde - PR Noise level in a 222 bed hospital in the 18th health region - PR

    Directory of Open Access Journals (Sweden)

    Marcelo Henrique Otenio

    2007-04-01

    Full Text Available A poluição sonora ambiental torna-se hoje onipresente e beira o intolerável. Nos hospitais, os avanços tecnológicos trazem, como conseqüência, níveis de ruído potencialmente danosos. Muito do ruído no hospital provém mais de dentro, do que de fora desse ambiente, sendo as principais causas de ruído em Unidade de Terapia Intensiva, por exemplo, os equipamentos e a conversação entre a equipe hospitalar. O objetivo deste trabalho foi avaliar o nível de ruído nos diversos ambientes hospitalares, em Hospital de 222 leitos na 18ª RS de Saúde - PR. MATERIAIS E MÉTODOS: Conduziu-se, em março de 2005 no período de 24 horas, em dez setores. Forma de Estudo: Aferição do nível de ruído ambiental utilizando um Decibelímetro modelo 1350. RESULTADOS: O nível de ruído encontrado em nosso estudo apresentou média total de 63,7 dB(A, que excede os valores máximos permitidos de 45 dB recomendados pela Associação Brasileira de Normas Técnicas (1987. CONCLUSÃO: Nos setores analisados, o nível de ruído encontrado neste está consideravelmente acima do recomendado. A equipe hospitalar deve estar consciente do ruído e dos efeitos deste, para que possa atuar de maneira mais efetiva na redução da poluição sonora, beneficiando assim a função laborativa dos profissionais e recuperação dos pacientes.Environment noise pollution is common place today, at intolerable levels. In hospitals, technological developments have, as a consequence, potentially harmful noise levels. Much of the hospital noise comes from inside, rather than outside, and the major source of such noise is the Intensive Care Unit, for example equipment and hospital staff talk. Our goal with the present study was to investigate the noise level present in the different hospital environments, within a 222 bed hospital located at the 18th health zone, PR. MATERIALS AND METHODS: The study was carried out in March, 2005, during a period of 24 hours, in tem different

  19. The Combined Effects of Aircraft and Road Traffic Noise and Aircraft and Railway Noise on Noise Annoyance—An Analysis in the Context of the Joint Research Initiative NORAH

    Directory of Open Access Journals (Sweden)

    Jördis Wothge

    2017-08-01

    Full Text Available The Noise Related Annoyance Cognition and Health (NORAH research initiative is one of the most extensive studies on the physiological and psychological long-term effects of transportation noise in Europe. It includes research on the quality of life and annoyance as well as cardiovascular effects, sleep disturbance, breast cancer, blood pressure, depression and the cognitive development of children. Within the realm of the annoyance module of the study approximately 10,000 residents of the Rhine-Main district were surveyed on the combined effects of transportation noise. This included combined noise from aircraft and road traffic noise (N = 4905, or aircraft and railway noise (N = 4777. Results show that judgment of the total noise annoyance of participants was strongly determined by the sound source which was judged as more annoying (in this case aircraft noise. To a lesser extent, the average sound pressure level of the two present sources was also of relevance.

  20. First trimester serum levels of the soluble transcobalamin receptor, holo-transcobalamin, and total transcobalamin in relation to preeclampsia risk

    DEFF Research Database (Denmark)

    Abuyaman, Omar; Torring, Niels; Obeid, Rima

    2016-01-01

    transcobalamin (TC) with the risk of subsequent preeclampsia using serum samples from asymptomatic first trimester pregnant women. Moreover, we aimed to establish reference intervals of the aforementioned biomarkers for first trimester pregnant women who remained healthy throughout pregnancy. STUDY DESIGN...... preeclampsia while the controls remained normotensive throughout pregnancy. We measured the serum concentration of sCD320, holoTC, and total TC by using in-house ELISA methods. RESULTS: First trimester median concentrations of sCD320, holoTC and total TC were not significantly different between cases...... and controls. The odd ratio for developing preeclampsia based on exposure to low or high levels of sCD320, holoTC or total TC at first trimester was not significant. The reference intervals (2.5-97.5% percentiles (median)) derived from the controls were 50-170 (90) pmol\\L for sCD320, 20-140 (70) pmol...

  1. The impact of an urban park on air pollution and noise levels in the Mediterranean city of Tel-Aviv, Israel.

    Science.gov (United States)

    Cohen, Pninit; Potchter, Oded; Schnell, Izhak

    2014-12-01

    This study examines the influence of urban parks on air quality and noise in the city of Tel-Aviv, Israel, by investigation of an urban park, an urban square and a street canyon. Simultaneous monitoring of several air pollutants and noise levels were conducted. The results showed that urban parks can reduce NOx, CO and PM10 and increase O3 concentrations and that park's mitigation effect is greater at higher NOx and PM10 levels. During extreme events, mean values of 413 ppb NOx and 80 μG/m3 PM10 were measured in the street while mean values of 89 ppb NOx and 24 μG/m3 PM10 were measured in the park. Whereas summer highest O3 values of 84 ppb were measured in the street, 94 ppb were measured in the park. The benefit of the urban park in reducing NOx and PM10 concentrations is more significant than the disadvantage of increased O3 levels. Furthermore, urban parks can reduce noise by ∼5 dB(A). Copyright © 2014 Elsevier Ltd. All rights reserved.

  2. Galectin-3 levels relate in children to total body fat, abdominal fat, body fat distribution, and cardiac size.

    Science.gov (United States)

    Dencker, Magnus; Arvidsson, Daniel; Karlsson, Magnus K; Wollmer, Per; Andersen, Lars B; Thorsson, Ola

    2018-03-01

    Galectin-3 has recently been proposed as a novel biomarker for cardiovascular disease in adults. The purpose of this investigation was to assess relationships between galectin-3 levels and total body fat, abdominal fat, body fat distribution, aerobic fitness, blood pressure, left ventricular mass, left atrial size, and increase in body fat over a 2-year period in a population-based sample of children. Our study included 170 children aged 8-11 years. Total fat mass and abdominal fat were measured by dual-energy x-ray absorptiometry (DXA). Body fat distribution was expressed as abdominal fat/total fat mass. Maximal oxygen uptake was assessed by indirect calorimetry during a maximal exercise test and scaled to body mass. Systolic and diastolic blood pressure and pulse pressure were measured. Left atrial size, left ventricular mass, and relative wall thickness were measured by echocardiography. Frozen serum samples were analyzed for galectin-3 by the Proximity Extension Assay technique. A follow-up DXA scan was performed in 152 children 2 years after the baseline exam. Partial correlations, with adjustment for sex and age, between galectin-3 versus body fat measurements indicated weak to moderate relationships. Moreover, left atrial size, left ventricular mass, and relative wall thickness and pulse pressure were also correlated with galectin-3. Neither systolic blood pressure nor maximal oxygen uptake was correlated with galectin-3. There was also a correlation between galectin-3 and increase in total body fat over 2 years, while no such correlations were found for the other fat measurements. More body fat and abdominal fat, more abdominal body fat distribution, more left ventricular mass, and increased left atrial size were all associated with higher levels of galectin-3. Increase in total body fat over 2 years was also associated with higher levels of galectin-3. What is Known: • Galectin-3 has been linked to obesity and been proposed to be a novel biomarker

  3. What Are Normal Metal Ion Levels After Total Hip Arthroplasty? A Serologic Analysis of Four Bearing Surfaces.

    Science.gov (United States)

    Barlow, Brian T; Ortiz, Philippe A; Boles, John W; Lee, Yuo-Yu; Padgett, Douglas E; Westrich, Geoffrey H

    2017-05-01

    The recent experiences with adverse local tissue reactions have highlighted the need to establish what are normal serum levels of cobalt (Co), chromium (Cr), and titanium (Ti) after hip arthroplasty. Serum Co, Cr, and Ti levels were measured in 80 nonconsecutive patients with well-functioning unilateral total hip arthroplasty and compared among 4 bearing surfaces: ceramic-on-ceramic (CoC); ceramic-on-polyethylene (CoP); metal-on-polyethylene (MoP), and dual mobility (DM). The preoperative and most recent University of California, Los Angeles (UCLA) and Western Ontario and McMaster Universities Arthritis Index (WOMAC) scores were compared among the different bearing surfaces. No significant difference was found among serum Co and Cr levels between the 4 bearing surface groups (P = .0609 and P = .1577). Secondary analysis comparing metal and ceramic femoral heads demonstrated that the metal group (MoP, modular dual mobility (Stryker Orthopedics, Mahwah, NJ) [metal]) had significant higher serum Co levels compared with the ceramic group (CoC, CoP, MDM [ceramic]) (1.05 mg/L ± 1.25 vs 0.59 mg/L ± 0.24; P = .0411). Spearman coefficient identified no correlation between metal ion levels and patient-reported outcome scores. No serum metal ion level differences were found among well-functioning total hip arthroplasty with modern bearing couples. Significantly higher serum Co levels were seen when comparing metal vs ceramic femoral heads in this study and warrants further investigation. Metal ion levels did not correlate with patient-reported outcome measures. Copyright © 2016 Elsevier Inc. All rights reserved.

  4. The Assessment of Noise Exposure and Noise Annoyance at a Petrochemical Company

    Directory of Open Access Journals (Sweden)

    S. Farhang Dehghan

    2013-12-01

    .Conclusion: Based on the obtained results of investigating the noise level (objective exposure as well as the noise annoyance (subjective exposure at the studied company, it is necessary to adopt the management –technical noise reduction measures at manufacturing sectors as the personal noise exposure and environmental noise exposure and also noise personal exposure of administrative staff can be decreased.

  5. The influence of road traffic noise on sleep

    Science.gov (United States)

    Eberhardt, J. L.

    1988-12-01

    The influence of road traffic noise on the sleep of adults and 6-11 year old children was studied by using electrophysiological methods. Young adults, unaccustomed to traffic noise, were disturbed by continuous and intermittent traffic noise at 45 dB(A). No sleep disturbances were found for continuous traffic noise at 36 dB(A). Car passages with a peak noise level of 55 dB(A) caused awakenings. The equivalent sound pressure level ( Leq) did not correlate with sleep disturbance effects. A better noise dose description was found in the number of vehicles per night that made most noise. Children wer about 10 dB(A) less sensitive than adults to awakening reactions, and even less sensitive with respect to disturbances of REM sleep and deep sleep. Total habituation to road traffic noise did not occur, even after at least one year of exposure. Sound reduction in the bedroom induced increased amounts of deep sleep for adults and reduced falling-asleep time for children. Road traffic noise during the first hours of a night's sleep tended to disturb sleep more than when it ocurred later in the night, the main effects being a reduction of the total amount of REM sleep during the night and an increased duration of intermittent wakefulness during the hours of exposure.

  6. Changes in iron levels, total iron binding capacity, transferrin saturation in race horses, before and after of physical exercise

    Directory of Open Access Journals (Sweden)

    Gláucia Abramovitc

    2014-09-01

    Full Text Available ABSTRACT. Abramovitc G., Parra A.C. & Fernandes W.R. [Changes in iron levels, total iron binding capacity, transferrin saturation in race horses, before and after of physical exercise]. Variação de níveis séricos de ferro, da capacidade total de ligação do ferro e da saturação da transferrina em equinos de corrida, antes e após exercício físico. Revista Brasileira de Medicina Veterinária, 36(3:289-293, 2014. Departamento de Clínica Médica, Faculdade de Medicina Veterinária e Zootecnia, Universidade de São Paulo, Rua Prof. Dr. Orlando Marques de Paiva 87, Cidade Universitária, Butantã, São Paulo, SP 05508-270, Brasil. Email: wilsonrf@usp.br The preparation of the horse for physical activities in competition is directly related to important factors such as nutrition, muscle adaptation and blood profile, related to the concentration of serum iron, total capacity total iron binding capacity (TIBC and saturation of transferrin. This study aimed to evaluate the influence of exercise in iron levels, the total iron and transferrin saturation in race horses. One hundred and eleven samples of blood serum were collected from Thoroughbred horses, from the Jockey Club of São Paulo, aged between 3 and 4 years old, male and female, clinically healthy, practitioners turf competition, in sand or grass. The samples were obtained before exercise (control time and 30 minutes after exercise (post exercise. These animals were submitted to gallop training, of high intensity and short duration for this research. As a result, it was observed that the serum concentration of iron (Fe showed a statistically significant lowering post-exercise, due to organic re-balance of iron, while TIBC (total iron binding capacity showed a clear and significant increase in their serum levels due to increased needs of iron during and after exercise. The percentage of transferrin saturation in serum was shown to be lower post-exercise, probably due to the recruitment of

  7. A Mixed-Methods Trial of Broad Band Noise and Nature Sounds for Tinnitus Therapy: Group and Individual Responses Modeled under the Adaptation Level Theory of Tinnitus.

    Science.gov (United States)

    Durai, Mithila; Searchfield, Grant D

    2017-01-01

    Objectives: A randomized cross-over trial in 18 participants tested the hypothesis that nature sounds, with unpredictable temporal characteristics and high valence would yield greater improvement in tinnitus than constant, emotionally neutral broadband noise. Study Design: The primary outcome measure was the Tinnitus Functional Index (TFI). Secondary measures were: loudness and annoyance ratings, loudness level matches, minimum masking levels, positive and negative emotionality, attention reaction and discrimination time, anxiety, depression and stress. Each sound was administered using MP3 players with earbuds for 8 continuous weeks, with a 3 week wash-out period before crossing over to the other treatment sound. Measurements were undertaken for each arm at sound fitting, 4 and 8 weeks after administration. Qualitative interviews were conducted at each of these appointments. Results: From a baseline TFI score of 41.3, sound therapy resulted in TFI scores at 8 weeks of 35.6; broadband noise resulted in significantly greater reduction (8.2 points) after 8 weeks of sound therapy use than nature sounds (3.2 points). The positive effect of sound on tinnitus was supported by secondary outcome measures of tinnitus, emotion, attention, and psychological state, but not interviews. Tinnitus loudness level match was higher for BBN at 8 weeks; while there was little change in loudness level matches for nature sounds. There was no change in minimum masking levels following sound therapy administration. Self-reported preference for one sound over another did not correlate with changes in tinnitus. Conclusions: Modeled under an adaptation level theory framework of tinnitus perception, the results indicate that the introduction of broadband noise shifts internal adaptation level weighting away from the tinnitus signal, reducing tinnitus magnitude. Nature sounds may modify the affective components of tinnitus via a secondary, residual pathway, but this appears to be less important

  8. The total workload of male and female white collar workers as related to age, occupational level, and number of children.

    Science.gov (United States)

    Lundberg, U; Mårdberg, B; Frankenhaeuser, M

    1994-12-01

    A questionnaire assessing various aspects of paid as well as unpaid forms of productive activity was mailed to stratified samples of male and female white collar workers, approximately matched for educational and occupational level. Data from 501 men and 679 women employed full time revealed traditional gender differences in terms of main responsibility for household duties, child care etc. In keeping with this, women reported higher levels of work overload, stress and conflict than men, which increased significantly with the number of children at home. The various stress indices reached a peak between the ages of 35 and 39. Men reported more autonomy in their paid work whereas women reported more control at home. Men and women at the upper managerial levels reported more control over their total work situation and less conflict between demands.

  9. Noise Pollution

    Science.gov (United States)

    ... Regulated by EPA EPA or a designated Federal agency regulates noise sources, such as rail and motor carriers, low noise emission products, construction equipment, transport equipment, trucks, motorcycles, and the labeling of hearing ...

  10. Mildly elevated serum total bilirubin levels are negatively associated with carotid atherosclerosis among elderly persons with type 2 diabetes.

    Science.gov (United States)

    Kawamoto, Ryuichi; Ninomiya, Daisuke; Hasegawa, Yoichi; Kasai, Yoshihisa; Kusunoki, Tomo; Ohtsuka, Nobuyuki; Kumagi, Teru; Abe, Masanori

    2016-01-01

    Diabetes is strongly associated with several mechanisms of tissue damage such as oxidative stress. Serum bilirubin may have a beneficial role in preventing oxidative changes in cardiovascular disease (CVD). Limited information is available on whether serum bilirubin is an independent confounding factor for carotid atherosclerosis among elderly persons with type 2 diabetes. The study subjects were 169 men aged 79 ± 8 (mean ± SD) years and 205 women aged 81 ± 8 years that were enrolled consecutively from patients in the medical department. Carotid intima-media thickness (IMT) and plaque were derived via B-mode ultrasonography. Multiple linear regression analysis showed that serum total bilirubin (β = -0.160) was significantly associated with carotid IMT. Compared to subjects with a serum total bilirubin of tertile-1 (0.13-0.58 mg/dL), the multivariate-adjusted odds ratio (95% confidence interval) of carotid IMT ≥1.0 mm including plaque and carotid plaque was 0.46 (0.23-0.93) and 0.32 (0.17-0.60) in the Tertile-3 group (0.87-1.93 mg/dL), respectively. Next, data were further stratified by gender, age, smoking status, medication and prevalence of CVD. There were no significant differences in serum total bilirubin levels between selected subgroups. Our data demonstrated a negative association between serum total bilirubin and carotid atherosclerosis among elderly persons with type 2 diabetes.

  11. 49 CFR Appendix A to Part 227 - Noise Exposure Computation

    Science.gov (United States)

    2010-10-01

    ... + . . . + Cn/Tn), where Cn indicates the total time of exposure at a specific noise level, and Tn indicates the....054 127 0.047 128 0.041 129 0.036 130 0.031 140 0.078 1 Numbers above 115 dB(A) are italicized to indicate that they are noise levels that are not permitted. The italicized numbers are included only...

  12. Community noise

    Science.gov (United States)

    Bragdon, C. R.

    Airport and community land use planning as they relate to airport noise reduction are discussed. Legislation, community relations, and the physiological effect of airport noise are considered. Noise at the Logan, Los Angeles, and Minneapolis/St. Paul airports is discussed.

  13. Individualized volume CT dose index determined by cross-sectional area and mean density of the body to achieve uniform image noise of contrast-enhanced pediatric chest CT obtained at variable kV levels and with combined tube current modulation

    International Nuclear Information System (INIS)

    Goo, Hyun Woo

    2011-01-01

    A practical body-size adaptive protocol providing uniform image noise at various kV levels is not available for pediatric CT. To develop a practical contrast-enhanced pediatric chest CT protocol providing uniform image noise by using an individualized volume CT dose index (CTDIvol) determined by the cross-sectional area and density of the body at variable kV levels and with combined tube current modulation. A total of 137 patients (mean age, 7.6 years) underwent contrast-enhanced pediatric chest CT based on body weight. From the CTDIvol, image noise, and area and mean density of the cross-section at the lung base in the weight-based group, the best fit equation was estimated with a very high correlation coefficient (γ 2 = 0.86, P 2 vs. 326.3 ± 124.8 cm 2 ), mean density (-212.9 ± 53.1 HU vs. -221.1 ± 56.3 HU), and image noise (13.8 ± 2.3 vs. 13.6 ± 1.7 HU) between the weight-based and the CTDIvol groups (P > 0.05). Contrast-enhanced pediatric chest CT with the CTDIvol determined individually by the cross-sectional area and density of the body provides more uniform noise and better dose adaptation to body habitus than does weight-based CT at variable kV levels and with combined tube current modulation. (orig.)

  14. Noise Pollution--What can be Done?

    Science.gov (United States)

    Shaw, Edgar A. G.

    1975-01-01

    Discusses the ratio of energy dissipated as sound to the mechanical output of devices. Considers noise levels, ranges vs. peaks, noise indexes, and health hazards. Indicates some problems vs. solutions in the technology of noise control. (GH)

  15. A transient increase in total head phosphotyrosine levels is observed upon the emergence of Aedes aegypti from the pupal stage

    Directory of Open Access Journals (Sweden)

    Willy Jablonka

    2011-08-01

    Full Text Available Phosphorylation and dephosphorylation of protein tyrosine residues constitutes a major biochemical regulatory mechanism for the cell. We report a transient increase in the total tyrosine phosphorylation of the Aedes aegypti head during the first days after emergence from the pupal stage. This correlates with an initial reduction in total head protein tyrosine phosphatase (PTP activity. Similarly, phosphotyrosine (pTyr-containing bands are seen in extracts prepared from both male and female heads and are spread among a variety of structures including the antennae, proboscis and the maxillary palps combined with the proboscis. Also, mosquitoes treated with sodium orthovanadate, a classical PTP inhibitor, show reduced blood-feeding activity and higher head tyrosine phosphorylation levels. These results suggest that pTyr-mediated signalling pathways may play a role in the initial days following the emergence of the adult mosquito from the pupal stage.

  16. A Literature Survey of Noise Pollution.

    Science.gov (United States)

    Shih, H. H.

    Physically, noise is a complex sound that has little or no periodicity. However, the essential characteristic of noise is its undesirability. Thus, noise can be defined as any annoying or unwanted sound. In recent years, the rapid increase of noise level in our environment has become a national public health hazard. Noise affects man's state of…

  17. Determination of deep-level impurities and their effects on the small-single and LF noise properties of ion-implanted GaAs MESFETs

    International Nuclear Information System (INIS)

    Sriram, S.; Kim, B.; Ghosh, P.K.; Das, M.B.; Pennsylvania State Univ., University Park; Pennsylvania State Univ., University Park

    1982-01-01

    A large number of deep levels, with energies ranging from Esub(c)-0.19eV to Esub(c)-0.9eV, have been identified and characterized using ion-implanted MESFET's on undoped and Cr-doped LEC-grown semi-insulating GaAs substrates. Measurement techniques used include deep level transient (DLTS) and steady state spectroscopic (DLSS) methods. Large capture cross-section values are obtained for levels below Esub(c)-0.5eV, possibly due to high electric field. Spectral densities of LF noise with distinct bulges have been shown to be related to deep levels. In some samples, natural deep level related oscillations have been observed and their ionization energies have been determined. (author)

  18. Environmental noise pollution and risk of preeclampsia.

    Science.gov (United States)

    Auger, Nathalie; Duplaix, Mathilde; Bilodeau-Bertrand, Marianne; Lo, Ernest; Smargiassi, Audrey

    2018-08-01

    Environmental noise exposure is associated with a greater risk of hypertension, but the link with preeclampsia, a hypertensive disorder of pregnancy, is unclear. We sought to determine the relationship between environmental noise pollution and risk of preeclampsia during pregnancy. We analyzed a population-based cohort comprising 269,263 deliveries on the island of Montreal, Canada between 2000 and 2013. We obtained total environmental noise pollution measurements (LA eq24 , L den , L night ) from land use regression models, and assigned noise levels to each woman based on the residential postal code. We computed odds ratios (OR) and 95% confidence intervals (CI) for the association of noise with preeclampsia in mixed logistic regression models with participants as a random effect, and adjusted for air pollution, neighbourhood walkability, maternal age, parity, multiple pregnancy, comorbidity, socioeconomic deprivation, and year of delivery. We assessed whether noise exposure was more strongly associated with severe or early onset preeclampsia than mild or late onset preeclampsia. Prevalence of preeclampsia was higher for women exposed to elevated environmental noise pollution levels (LA eq24h  ≥ 65 dB(A) = 37.9 per 1000 vs. <50 dB(A) = 27.9 per 1000). Compared with 50 dB(A), an LA eq24h of 65.0 dB(A) was not significantly associated the risk of preeclampsia (OR 1.09, 95% CI 0.99-1.20). Associations were however present with severe (OR 1.29, 95% CI 1.09-1.54) and early onset (OR 1.71, 95% CI 1.20-2.43) preeclampsia, with results consistent across all noise indicators. The associations were much weaker or absent for mild and late preeclampsia. Environmental noise pollution may be a novel risk factor for pregnancy-related hypertension, particularly more severe variants of preeclampsia. Copyright © 2018 Elsevier Ltd. All rights reserved.

  19. Total and allergen-specific IgE levels during and after pregnancy in relation to maternal allergy.

    Science.gov (United States)

    Sandberg, Martina; Frykman, Anne; Jonsson, Yvonne; Persson, Marie; Ernerudh, Jan; Berg, Göran; Matthiesen, Leif; Ekerfelt, Christina; Jenmalm, Maria C

    2009-07-01

    Type 2 T-helper cell (Th2)-skewed immunity is associated with successful pregnancy and the ability to easily direct immune responses to a Th2-polarised profile may be an evolutionary benefit. The Th2-like immunity associated with allergic disease might generate favourable effects for the maintenance of pregnancy, but could also promote development of Th2-like immune responses and allergic disease in the offspring. The aim of this study was to explore, by using IgE as a stable proxy for Th2, the Th1/Th2 balance in allergic and non-allergic women by measuring allergen-specific and total IgE antibody levels in plasma during pregnancy and after delivery. Specific and total IgE antibody levels were determined by ImmunoCAP technology at five occasions during pregnancy (gestational weeks 10-12, 15-16, 25, 35 and 39), as well as at 2 and 12 months after delivery. Thirty-six women without and 20 women with allergic symptoms were included, of whom 13 were sensitised with allergic symptoms and 30 were non-sensitised without allergic symptoms. The levels of total IgE, but not allergen-specific IgE, were increased during early pregnancy when compared to 12 months after delivery in the sensitised women with allergic symptoms, but not in the non-sensitised women without allergic symptoms (ppregnancy only in the sensitised women with allergic symptoms indicates that allergy is associated with an enhanced Th2 deviation during pregnancy.

  20. Total and Bioaccessible Soil Arsenic and Lead Levels and Plant Uptake in Three Urban Community Gardens in Puerto Rico

    Directory of Open Access Journals (Sweden)

    John Misenheimer

    2018-01-01

    Full Text Available Arsenic (As and lead (Pb are two contaminants of concern associated with urban gardening. In Puerto Rico, data currently is limited on As and Pb levels in urban garden soils, soil metal (loid bioaccessibility, and uptake of As and Pb in soil by edible plants grown in the region. This study examined total and bioaccessible soil As and Pb concentrations and accumulation in 10 commonly grown garden plants collected from three urban community gardens in Puerto Rico. Bioavailability values were predicted using bioaccessibility data to compare site-specific bioavailability estimates to commonly used default exposure assumptions. Total and bioaccessible As levels in study soils ranged from 2 to 55 mg/kg and 1 to 18 mg/kg, respectively. Total and bioaccessible Pb levels ranged from 19 to 172 mg/kg and 17 to 97 mg/kg, respectively. Measured bioaccessibility values corresponded to 19% to 42% bioaccessible As and 61% to 100% bioaccessible Pb when expressed as a percent of total As and Pb respectively. Predicted relative percent bioavailability of soil As and Pb based on measured bioaccessibility values ranged from 18% to 36% and 51% to 85% for As and Pb respectively. Transfer factors (TFs measuring uptake of As in plants from soil ranged from 0 to 0.073 in the edible flesh (fruit or vegetable of plant tissues analyzed and 0.073 to 0.444 in edible leaves. Pb TFs ranged from 0.002 to 0.012 in flesh and 0.023 to 0.204 in leaves. Consistent with TF values, leaves accumulated higher concentrations of As and Pb than the flesh, with the highest tissue concentrations observed in the culantro leaf (3.2 mg/kg dw of As and 8.9 mg/kg dw of Pb. Leaves showed a general but not statistically-significant (α = 0.05 trend of increased As and Pb concentration with increased soil levels, while no trend was observed for flesh tissues. These findings provide critical data that can improve accuracy and reduce uncertainty when conducting site-specific risk determination of

  1. Evaluation of noise pollution in oil extracting region of Lavan and the effect of noise enclosure on noise abatement

    Directory of Open Access Journals (Sweden)

    F. Golbabaei

    2007-09-01

    Full Text Available Background and aims   Overexposure to industrial noise pollution induce hearing loss workers. Occupational hearing loss may cause interference whit oral communication, so it may  increase the risk of occupational accidents in workplace as well as affects whit social activities.  This study was conducted on Lavan Island, are of oil extracting regions in the south of Iran. The  object of this study was to evaluate noise pollution and determining the effect of noise enclosure  on noise abatement.   Methods   The noise sources were recognized and noise pressure level was measured by CEL- 440. Noise dose of the exposed workers in high level noise area were measured by CEL 272.   Results   Major noise sources were gas turbines, diesel generators, compressors, fans and gas containing pips, noise contour map revealers that noise level were higher than the recommended national exposure limit. The results of workers noise dose show that their noise exposure were  higher than the recommended value, (p<0.001. Finally, by using the results of noise frequency  analysis of different noise sources, the noise pressure level of each sources was determined in   terms of enclosing them.   Conclusion   By enclosing the noise sources, noise pressure levels can be lowered douse to  acceptable levels but limitation of applying enclosure should be regarded.  

  2. Psychophysical assessment of sinusoidal whole-body vibration in z-axis between 0.6 and 5 Hz combined with different noise levels.

    Science.gov (United States)

    Seidel, H; Richter, J; Kurerov, N N; Schajpak, E J; Blüthner, R; Erdmann, U; Hinz, B

    1989-01-01

    Nine healthy sitting males evaluated the intensity of vertical whole-body vibration (WBV) in z-axis at four frequencies (F1 = 0.63 Hz, F2 = 1.25 Hz, F3 = 2.5 Hz, F4 = 5 Hz) and two intensities (I1 = 1 ms-2 rms, I2 = 2 ms-2 rms) by cross-modality matching (CMM). The subjects were simultaneously exposed to low-frequency noise at two levels (L1 = 65 dBA, L2 = 86 dBA). L1 and L2 were context conditions which did not have to be evaluated by CMM. The results indicate a flat response between F2 and F3; the sensitivity increases towards F1. Different exponents of Stevens' power law for the frequencies of WBV contradict the frequency range tested to be a sensory continuum. L2 caused practically significantly stronger sensations of the WBV-intensity from F1 to F3 (I1) and at F2 (I2). No synergistic effect of noise and WBV was shown at F3I2. Weighting factors were calculated for all exposure conditions using Stevens' power law. The weighting of F2 and F3 contradicts that of the International Standard ISO 2631-1985 (E). The results enable recommendations for the frequency weighting of WBV between 0.63 and 1 Hz, as well as for the equivalence of noise and WBV with combined exposure.

  3. Nível de ruído em unidade de terapia intensiva neonatal Nivel de ruido en una unidad de cuidados intensivos neonatal Noise level in neonatal intensive care unit

    Directory of Open Access Journals (Sweden)

    Tereza Yoshiko Kakehashi

    2007-12-01

    los profesionales y familiares.OBJECTIVE: Determine noise levels in the Neonatal Intensive Care Unit and identify the sources of these noises. METHODS: Quantitative, descriptive and exploratory study, carried out in São Paulo. Data was collected in April and May of 2005. A dosimeter was used to record a total of 96 hours of measurements. Nine hours of observation were also conducted to identify sources of noise. RESULTS: Leq noise levels ranged from of 61.3 to 66.6 dBA and were higher on the weekends. Peak values ranged from 90.8 to 123.4 dBC and the highest values were recorded at night. The sources of the noise were: beeping noises from ventilators and heart rate monitors, conversations between health professional and others. CONCLUSION: The deleterious effects of high levels of noise on newborns and health professionals show the need for interventions in routines and professionals and families' conduct.

  4. Plasma total antioxidant capacity is associated with dietary intake and plasma level of antioxidants in postmenopausal women.

    Science.gov (United States)

    Wang, Ying; Yang, Meng; Lee, Sang-Gil; Davis, Catherine G; Kenny, Anne; Koo, Sung I; Chun, Ock K

    2012-12-01

    Increased plasma total antioxidant capacity (TAC) has been associated with a high consumption of fruits and vegetables. However, limited information is available on whether plasma TAC reflects the dietary intake of antioxidants and the levels of individual antioxidants in plasma. By using three different assays, the study aimed to determine if plasma TAC can effectively predict dietary intake of antioxidants and plasma antioxidant status. Forty overweight and apparently healthy postmenopausal women were recruited. Seven-day food records and 12-h fasting blood samples were collected for dietary and plasma antioxidant assessments. Plasma TAC was determined by vitamin C equivalent antioxidant capacity (VCEAC), ferric-reducing ability of plasma (FRAP) and oxygen radical absorbance capacity (ORAC) assays. TAC values determined by VCEAC were highly correlated with FRAP (r=0.79, Pantioxidants and represents more closely the plasma antioxidant levels than ORAC and FRAP. Copyright © 2012 Elsevier Inc. All rights reserved.

  5. The organic contamination level based on the total soil mass is not a proper index of the soil contamination intensity

    Science.gov (United States)

    Hung, H.-W.; Daniel, Sheng G.; Lin, T.-F.; Su, Y.; Chiou, C.T.

    2009-01-01

    Concentrations of organic contaminants in common productive soils based on the total soil mass give a misleading account of actual contamination effects. This is attributed to the fact that productive soils are essentially water-saturated, with the result that the soil uptake of organic compounds occurs principally by partition into the soil organic matter (SOM). This report illustrates that the soil contamination intensity of a compound is governed by the concentration in the SOM (Com) rather than by the concentration in whole soil (Cs). Supporting data consist of the measured levels and toxicities of many pesticides in soils of widely differing SOM contents and the related levels in in-situ crops that defy explanation by the Cs values. This SOM-based index is timely needed for evaluating the contamination effects of food crops grown in different soils and for establishing a dependable priority ranking for intended remediation of numerous contamination sites.

  6. Correlation of the concentration of the carbon-associated radiation damage levels with the total carbon concentration in silicon

    Energy Technology Data Exchange (ETDEWEB)

    Ferenczi, G.; Londos, C.A.; Pavelka, T.; Somogyi, M.; Mertens, A.

    1988-01-01

    The dominant carbon-related radiation damage center in silicon was studied in detail by deep level transient spectroscopy. Samples with different carbon and oxygen content were implanted with gradually increasing proton fluence. Two energetically closely spaced levels were revealed and tentative identities were assigned. One at E/sub T/+E/sub V/ = 0.344 eV (sigma/sub p/ = 1.1 x 10/sup -16/ cm/sup 2/) is assigned as the C+O/sub i/ complex, and that at E/sub T/+E/sub V/ = 0.370 eV (sigma/sub p/ = 8 x 10/sup -18/ cm/sup 2/) is assigned as the C/sub s/-Si/sub i/-C/sub s/ complex. It was shown that the concentration of these defects is correlated to the total concentration of carbon in the crystal.

  7. Noise from wind turbines

    International Nuclear Information System (INIS)

    Andersen, B.; Larsen, P.

    1993-01-01

    Denmark has 3200 wind turbines with an installed maximum capacity of 418MW. The most important Danish research projects into wind turbine noise and the main results are listed. These date from 1983. Two comprehensive studies are currently in progress. The first is an analytical and empirical investigation of aerodynamic noise from wind turbine rotors and has so far dealt mainly with tip noise. The measurement method, using a hard board mounted microphone on the ground near the turbine, is described. Four different tip designs have been tested. Some examples of reference sound power level spectra for three of the designs are presented. During the past two years a computerbased data acquisition system has been used for real-time determination of sound power levels. The second study, which has just commenced, is on annoyance from wind turbine noise. It will include noise measurements, masking calculations and a social survey on the perceived nuisance. (UK)

  8. Serum total homocysteine and lipoprotein (a) levels in acute myocardial infarction and their response to treatment with vitamins serum total homocysteine and lipoprotein (a) levels in acute myocardial infarction and their response to treatment with vitamins

    International Nuclear Information System (INIS)

    Haq, A.M.M.; Huque, M.M.

    2011-01-01

    To assess the relationship of serum total homocysteine (tHcy) and lipoprotein (a) [Lp(a)] levels with systemic hypertension, Diabetes mellitus and smoking as risk factors in patients with acute myocardial infarction (AMI) and changes in the former levels with vitamins supplementation. Study Design: An interventional study. Place and Duration of Study: Medical College for Women and Hospital (MCW and H), Dhaka, Bangladesh, from July 2008 to December 2009. Methodology: Consecutive AMI patients were recruited from the Coronary Care Unit (CCU) at MCW and H, Dhaka. Blood samples were collected at inclusion (Patient-I0). They were given conventional treatments and prescribed vitamins (vitamins B6=25 mg, B12=2 mg and folic acid=2.5 mg) daily for 2 months. After follow-up, blood samples were taken again (Patient-II0). A group of 25 normal subjects were also included as controls. Serum tHcy and Lp(a) were measured by kinetic method and nephelometric method respectively. Results: Serum tHcy (macor mol/L) and Lp(a) (mg/dl) levels were elevated in Patient-I that reduced in Patient-II after vitamins supplementation, but not to the normal control level. tHcy of Patient-I0 was 25.1 +- 4.7 macro mol/L, of Patient-II0 was 20.1 +- 4.5 mu mol/L and of controls 12.1 +- 3.3, p 0.1). However, in a significant proportion of patients tHcy and Lp(a) levels were reduced to control levels (tHcy: p < 0.001, Lp(a): p < 0.01). Conclusion: These results indicated that tHcy and Lp(a) levels were possibly atherogenic risk factors independent of conventional risk factors. Since both tHcy and Lp(a) levels responded in a similar fashion, a common point of the metabolic and pathogenetic pathways of tHcy and Lp(a) may be influenced by the vitamins supplementation. (author)

  9. Application of annular centrifugal contactors in the hot test of the improved total partitioning process for high level liquid waste.

    Science.gov (United States)

    Duan, Wuhua; Chen, Jing; Wang, Jianchen; Wang, Shuwei; Feng, Xiaogui; Wang, Xinghai; Li, Shaowei; Xu, Chao

    2014-08-15

    High level liquid waste (HLLW) produced from the reprocessing of the spent nuclear fuel still contains moderate amounts of uranium, transuranium (TRU) actinides, (90)Sr, (137)Cs, etc., and thus constitutes a permanent hazard to the environment. The partitioning and transmutation (P&T) strategy has increasingly attracted interest for the safe treatment and disposal of HLLW, in which the partitioning of HLLW is one of the critical technical issues. An improved total partitioning process, including a TRPO (tri-alkylphosphine oxide) process for the removal of actinides, a CESE (crown ether strontium extraction) process for the removal of Sr, and a CECE (calixcrown ether cesium extraction) process for the removal of Cs, has been developed to treat Chinese HLLW. A 160-hour hot test of the improved total partitioning process was carried out using 72-stage 10-mm-dia annular centrifugal contactors (ACCs) and genuine HLLW. The hot test results showed that the average DFs of total α activity, Sr and Cs were 3.57 × 10(3), 2.25 × 10(4) and 1.68 × 10(4) after the hot test reached equilibrium, respectively. During the hot test, 72-stage 10-mm-dia ACCs worked stable, continuously with no stage failing or interruption of the operation. Copyright © 2014 Elsevier B.V. All rights reserved.

  10. Automatic control of the NMB level in general anaesthesia with a switching total system mass control strategy.

    Science.gov (United States)

    Teixeira, Miguel; Mendonça, Teresa; Rocha, Paula; Rabiço, Rui

    2014-12-01

    This paper presents a model based switching control strategy to drive the neuromuscular blockade (NMB) level of patients undergoing general anesthesia to a predefined reference. A single-input single-output Wiener system with only two parameters is used to model the effect of two different muscle relaxants, atracurium and rocuronium, and a switching controller is designed based on a bank of total system mass control laws. Each of such laws is tuned for an individual model from a bank chosen to represent the behavior of the whole population. The control law to be applied at each instant corresponds to the model whose NMB response is closer to the patient's response. Moreover a scheme to improve the reference tracking quality based on the analysis of the patient's response, as well as, a comparison between the switching strategy and the Extended Kalman Kilter (EKF) technique are presented. The results are illustrated by means of several simulations, where switching shows to provide good results, both in theory and in practice, with a desirable reference tracking. The reference tracking improvement technique is able to produce a better reference tracking. Also, this technique showed a better performance than the (EKF). Based on these results, the switching control strategy with a bank of total system mass control laws proved to be robust enough to be used as an automatic control system for the NMB level.

  11. Effects of road traffic background noise on judgments of individual airplane noises. Ph.D. Thesis

    Science.gov (United States)

    Powell, C. A.

    1979-01-01

    Two laboratory experiments were conducted to investigate the effects of road-traffic background noise on judgments of individual airplane flyover noises. In the first experiment, 27 subjects judged a set of 16 airplane flyover noises in the presence of traffic-noise sessions of 30-min duration consisting of the combinations of 3 traffic-noise types and 3 noise levels. In the second experiment, 24 subjects judged the same airplane flyover noises in the presence of traffic-noise sessions of 10-min duration consisting of the combinations of 2 traffic-noise types and 4 noise levels. In both experiments the airplane noises were judged less annoying in the presence of high traffic-noise levels than in the presence of low traffic-noise levels.

  12. Analysis of a Shock-Associated Noise Prediction Model Using Measured Jet Far-Field Noise Data

    Science.gov (United States)

    Dahl, Milo D.; Sharpe, Jacob A.

    2014-01-01

    A code for predicting supersonic jet broadband shock-associated noise was assessed using a database containing noise measurements of a jet issuing from a convergent nozzle. The jet was operated at 24 conditions covering six fully expanded Mach numbers with four total temperature ratios. To enable comparisons of the predicted shock-associated noise component spectra with data, the measured total jet noise spectra were separated into mixing noise and shock-associated noise component spectra. Comparisons between predicted and measured shock-associated noise component spectra were used to identify deficiencies in the prediction model. Proposed revisions to the model, based on a study of the overall sound pressure levels for the shock-associated noise component of the measured data, a sensitivity analysis of the model parameters with emphasis on the definition of the convection velocity parameter, and a least-squares fit of the predicted to the measured shock-associated noise component spectra, resulted in a new definition for the source strength spectrum in the model. An error analysis showed that the average error in the predicted spectra was reduced by as much as 3.5 dB for the revised model relative to the average error for the original model.

  13. Correlation of Seminal Plasma Total Antioxidant Capacity and Malondialdehyde Levels With Sperm Parameters in Men With Idiopathic Infertility

    Directory of Open Access Journals (Sweden)

    Fazeli

    2016-01-01

    Full Text Available Background Oxidative stress is the result of an imbalance between the production and scavenging of reactive oxygen species (ROS. Recently, oxidative stress has been introduced as a major cause of male infertility. Objectives The aim of the present study was to determine the correlation between total antioxidant capacity (TAC and malondialdehyde (MDA as markers of oxidative stress in relation to idiopathic male infertility and sperm parameters. Patients and Methods This case control study was conducted using 35 men with idiopathic infertility and 34 men with proven fertility. Seminal plasma TAC and MDA were measured by ferric reducing ability of plasma (FRAP and thiobarbituric acid (TBA reaction methods, respectively. Results Seminal TAC levels were significantly lower and seminal MDA levels were significantly higher in men with idiopathic infertility than in fertile men (P < 0.0001 and P = 0.004, respectively. A positive correlation was shown between sperm motility, sperm morphology, and TAC levels in men with idiopathic infertility (P = 0.002 and P = 0.002, respectively. In addition, there was a correlation between sperm motility and TAC levels in fertile men (P = 0.005. There was no correlation between sperm count and TAC levels in either men with idiopathic infertility or in fertile men. Negative correlations were observed between MDA levels and sperm motility, morphology, and sperm count only in men with idiopathic infertility (P = 0.003, P = 0.001, and P = 0.006, respectively. Conclusions Our results show that oxidative stress could play an important role in male infertility as well as in sperm motility and sperm morphology.