WorldWideScience

Sample records for total measured organics

  1. Selection criteria for oxidation method in total organic carbon measurement.

    Science.gov (United States)

    Yoon, GeunSeok; Park, Sang-Min; Yang, Heuiwon; Tsang, Daniel C W; Alessi, Daniel S; Baek, Kitae

    2018-05-01

    During the measurement of total organic carbon (TOC), dissolved organic carbon is converted into CO 2 by using high temperature combustion (HTC) or wet chemical oxidation (WCO). However, the criteria for selecting the oxidation methods are not clear. In this study, the chemical structures of organic material were considered as a key factor to select the oxidation method used. Most non-degradable organic compounds showed a similar oxidation efficiency in both methods, including natural organic compounds, dyes, and pharmaceuticals, and thus both methods are appropriate to measure TOC in waters containing these compounds. However, only a fraction of the carbon in the halogenated compounds (perfluorooctanoic acid and trifluoroacetic acid) were oxidized using WCO, resulting in measured TOC values that are considerably lower than those determined by HTC. This result is likely due to the electronegativity of halogen elements which inhibits the approach of electron-rich sulfate radicals in the WCO, and the higher bond strength of carbon-halogen pairs as compared to carbon-hydrogen bonds, which results in a lower degree of oxidation of the compounds. Our results indicate that WCO could be used to oxidize most organic compounds, but may not be appropriate to quantify TOC in organic carbon pools that contain certain halogenated compounds. Copyright © 2018 Elsevier Ltd. All rights reserved.

  2. METHOD 415.3 - MEASUREMENT OF TOTAL ORGANIC ...

    Science.gov (United States)

    2.0 SUMMARY OF METHOD2.1 In both TOC and DOC determinations, organic carbon in the water sample is oxidized to form carbon dioxide (CO2), which is then measured by a detection system. There are two different approaches for the oxidation of organic carbon in water samples to carbon dioxide gas: (a) combustion in an oxidizing gas and (b) UV promoted or heat catalized chemical oxidation with a persulfate solution. Carbon dioxide, which is released from the oxidized sample, is detected by a conductivity detector or by a nondispersive infrared (NDIR) detector. Instruments using any combination of the above technologies may be used in this method.2.2. Setteable solids and floating matter may cause plugging of valves, tubing, and the injection needle port. The TOC procedure allows the removal of settleable solids and floating matter. The suspended matter is considered part of the sample. The resulting water sample is then considered a close approximation of the original whole water sample for the purpose of TOC measurement.2.3. The DOC procedure requires that the sample be passed through a 0.45 um filter prior to analysis.2.4. The TOC and DOC procedures require that all inorganic carbon be removed from the sample before the sample is analyzed for organic carbon content. If the inorganic carbon (IC) is not completely removed, significant error will occur. The inorganic carbon interference is removed by converting the mineralized IC to CO2 by acidification and

  3. Evaluation of trace organic contaminants in ultra-pure water production processes by measuring total organic halogen formation potential

    International Nuclear Information System (INIS)

    Urano, Kohei; Iwase, Yoko

    1984-01-01

    A new procedure for the determination of organic substances in water with high accuracy and high sensitivity was proposed, in which a hypochlorite is added to water, and the resultant total amount of organic halogen compounds (TOX formation potential) was measured, and it was applied to the evaluation of trace organic contaminants in ultra-pure water production process. In this investigation, the TOX formation potential of the raw water which was to be used for the ultra-pure water production process, intermediately treated water and ultra-pure water was measured to clarify the behavior of organic substances in the ultra-pure water production process and to demonstrate the usefulness of this procedure to evaluate trace organic contaminants in water. The measurement of TOX formation potential requires no specific technical skill, and only a short time, and gives accurate results, therefore, it is expected that the water quality control in the ultra-pure water production process can be performed more exactly by applying this procedure. (Yoshitake, I.)

  4. An improved method for quantitatively measuring the sequences of total organic carbon and black carbon in marine sediment cores

    Science.gov (United States)

    Xu, Xiaoming; Zhu, Qing; Zhou, Qianzhi; Liu, Jinzhong; Yuan, Jianping; Wang, Jianghai

    2018-01-01

    Understanding global carbon cycle is critical to uncover the mechanisms of global warming and remediate its adverse effects on human activities. Organic carbon in marine sediments is an indispensable part of the global carbon reservoir in global carbon cycling. Evaluating such a reservoir calls for quantitative studies of marine carbon burial, which closely depend on quantifying total organic carbon and black carbon in marine sediment cores and subsequently on obtaining their high-resolution temporal sequences. However, the conventional methods for detecting the contents of total organic carbon or black carbon cannot resolve the following specific difficulties, i.e., (1) a very limited amount of each subsample versus the diverse analytical items, (2) a low and fluctuating recovery rate of total organic carbon or black carbon versus the reproducibility of carbon data, and (3) a large number of subsamples versus the rapid batch measurements. In this work, (i) adopting the customized disposable ceramic crucibles with the microporecontrolled ability, (ii) developing self-made or customized facilities for the procedures of acidification and chemothermal oxidization, and (iii) optimizing procedures and carbon-sulfur analyzer, we have built a novel Wang-Xu-Yuan method (the WXY method) for measuring the contents of total organic carbon or black carbon in marine sediment cores, which includes the procedures of pretreatment, weighing, acidification, chemothermal oxidation and quantification; and can fully meet the requirements of establishing their highresolution temporal sequences, whatever in the recovery, experimental efficiency, accuracy and reliability of the measurements, and homogeneity of samples. In particular, the usage of disposable ceramic crucibles leads to evidently simplify the experimental scenario, which further results in the very high recovery rates for total organic carbon and black carbon. This new technique may provide a significant support for

  5. Determination of iodide, iodate and organo-iodine in waters with a new total organic iodine measurement approach.

    Science.gov (United States)

    Gong, Tingting; Zhang, Xiangru

    2013-11-01

    The dissolved iodine species that dominate aquatic systems are iodide, iodate and organo-iodine. These species may undergo transformation to one another and thus affect the formation of iodinated disinfection byproducts during disinfection of drinking waters or wastewater effluents. In this study, a fast, sensitive and accurate method for determining these iodine species in waters was developed by derivatizing iodide and iodate to organic iodine and measuring organic iodine with a total organic iodine (TOI) measurement approach. Within this method, organo-iodine was determined directly by TOI measurement; iodide was oxidized by monochloramine to hypoiodous acid and then hypoiodous acid reacted with phenol to form organic iodine, which was determined by TOI measurement; iodate was reduced by ascorbic acid to iodide and then determined as iodide. The quantitation limit of organo-iodine or sum of organo-iodine and iodide or sum of organo-iodine, iodide and iodate was 5 μg/L as I for a 40 mL water sample (or 2.5 μg/L as I for an 80 mL water sample, or 1.25 μg/L as I for a 160 mL water sample). This method was successfully applied to the determination of iodide, iodate and organo-iodine in a variety of water samples, including tap water, seawater, urine and wastewater. The recoveries of iodide, iodate and organo-iodine were 91-109%, 90-108% and 91-108%, respectively. The concentrations and distributions of iodine species in different water samples were obtained and compared. Copyright © 2013 Elsevier Ltd. All rights reserved.

  6. Deriving an atmospheric budget of total organic bromine using airborne in-situ measurements from the Western Pacific during SHIVA

    Science.gov (United States)

    Sala, S.; Bönisch, H.; Keber, T.; Oram, D. E.; Mills, G.; Engel, A.

    2014-02-01

    During the SHIVA (Stratospheric Ozone: Halogen Impacts in a Varying Atmosphere) project an extensive dataset of all halogen species relevant for the atmospheric budget of total organic bromine has been collected in the West Pacific region using the FALCON aircraft operated by the German Aerospace agency DLR (Deutsches Zentrum für Luft- und Raumfahrt) covering a vertical range from the planetary boundary layer up to the ceiling altitude of the aircraft of 13 km. In total, more than 700 measurements were performed with the newly developed fully-automated in-situ instrument GHOST-MS (Gas cHromatograph for the Observation of Tracers - coupled with a Mass Spectrometer) by the Goethe University of Frankfurt (GUF) and with the onboard whole-air sampler WASP with subsequent ground based state-of-the-art GC/MS analysis by the University of East Anglia (UEA). Both instruments yield good agreement for all major (CHBr3 and CH2Br2) and minor (CHBrCl, CHBrCl2 and CHBr2Cl) VSLS (very short-lived substances), at least at the level of their 2 σ measurement uncertainties. In contrast to the suggestion that the Western Pacific could be a major source region for VSLS (Pyle et al., 2011), we found only slightly enhanced mixing ratios of brominated halogen source gases relative to the levels reported in Montzka et al. (2011) for other tropical regions. A budget for total organic bromine, including all four halons,CH3Br and the VSLS, is derived for the upper troposphere, the input region for the TTL and thus also for the stratosphere, compiled from the SHIVA dataset. With exception of the two minor VSLS CHBrCl2 and CHBr2Cl, excellent agreement with the values reported in Montzka et al. (2011) is found, while being slightly higher than previous studies from our group based on balloon-borne measurements.

  7. Deriving an atmospheric budget of total organic bromine using airborne in situ measurements from the western Pacific area during SHIVA

    Science.gov (United States)

    Sala, S.; Bönisch, H.; Keber, T.; Oram, D. E.; Mills, G.; Engel, A.

    2014-07-01

    During the recent SHIVA (Stratospheric Ozone: Halogen Impacts in a Varying Atmosphere) project an extensive data set of all halogen species relevant for the atmospheric budget of total organic bromine was collected in the western Pacific region using the Falcon aircraft operated by the German Aerospace agency DLR (Deutsches Zentrum für Luft- und Raumfahrt) covering a vertical range from the planetary boundary layer up to the ceiling altitude of the aircraft of 13 km. In total, more than 700 measurements were performed with the newly developed fully automated in situ instrument GHOST-MS (Gas chromatograph for the Observation of Tracers - coupled with a Mass Spectrometer) by the Goethe University of Frankfurt (GUF) and with the onboard whole-air sampler WASP with subsequent ground-based state-of-the-art GC / MS analysis by the University of East Anglia (UEA). Both instruments yield good agreement for all major (CHBr3 and CH2Br2) and minor (CH2BrCl, CHBrCl2 and CHBr2Cl) VSLS (very short-lived substances), at least at the level of their 2σ measurement uncertainties. In contrast to the suggestion that the western Pacific could be a region of strongly increased atmospheric VSLS abundance (Pyle et al., 2011), we found only in the upper troposphere a slightly enhanced amount of total organic bromine from VSLS relative to the levels reported in Montzka and Reimann et al. (2011) for other tropical regions. From the SHIVA observations in the upper troposphere, a budget for total organic bromine, including four halons (H-1301, H-1211, H-1202, H-2402), CH3Br and the VSLS, is derived for the level of zero radiative heating (LZRH), the input region for the tropical tropopause layer (TTL) and thus also for the stratosphere. With the exception of the two minor VSLS CHBrCl2 and CHBr2Cl, excellent agreement with the values reported in Montzka and Reimann et al. (2011) is found, while being slightly higher than previous studies from our group based on balloon-borne measurements.

  8. Organic and total mercury determination in sediments by cold vapor atomic absorption spectrometry: methodology validation and uncertainty measurements

    Directory of Open Access Journals (Sweden)

    Robson L. Franklin

    2012-01-01

    Full Text Available The purpose of the present study was to validate a method for organic Hg determination in sediment. The procedure for organic Hg was adapted from literature, where the organomercurial compounds were extracted with dichloromethane in acid medium and subsequent destruction of organic compounds by bromine chloride. Total Hg was performed according to 3051A USEPA methodology. Mercury quantification for both methodologies was then performed by CVAAS. Methodology validation was verified by analyzing certified reference materials for total Hg and methylmercury. The uncertainties for both methodologies were calculated. The quantification limit of 3.3 µg kg-1 was found for organic Hg by CVAAS.

  9. German standard methods for the examination of water, waste water and sludge: General measurements of effects and substances (group H), determination of total organic carbon (TOC) (H 3)

    International Nuclear Information System (INIS)

    1982-01-01

    The following method for the determination of the total organic bound carbon is proposed. The carbon of the organic compounds is oxidized to carbon dioxide. There are three oxidation possibilities. Combustion, oxidation with proper oxidation agents in the solution and oxidation by irradiation of ultraviolette light. The resulting carbon dioxide or the possible reduction product methane are analysed with the following measuring instruments: Infrared spectroscopy, acidimetry, coulometry, conductometry, CO 2 sensitive electrodes, heat conductivity detection and flame ionisation detection. (VG) [de

  10. Characterization of a catalyst-based conversion technique to measure total particulate nitrogen and organic carbon and comparison to a particle mass measurement instrument

    Science.gov (United States)

    Stockwell, Chelsea E.; Kupc, Agnieszka; Witkowski, Bartłomiej; Talukdar, Ranajit K.; Liu, Yong; Selimovic, Vanessa; Zarzana, Kyle J.; Sekimoto, Kanako; Warneke, Carsten; Washenfelder, Rebecca A.; Yokelson, Robert J.; Middlebrook, Ann M.; Roberts, James M.

    2018-05-01

    The chemical composition of aerosol particles is a key aspect in determining their impact on the environment. For example, nitrogen-containing particles impact atmospheric chemistry, air quality, and ecological N deposition. Instruments that measure total reactive nitrogen (Nr = all nitrogen compounds except for N2 and N2O) focus on gas-phase nitrogen and very few studies directly discuss the instrument capacity to measure the mass of Nr-containing particles. Here, we investigate the mass quantification of particle-bound nitrogen using a custom Nr system that involves total conversion to nitric oxide (NO) across platinum and molybdenum catalysts followed by NO-O3 chemiluminescence detection. We evaluate the particle conversion of the Nr instrument by comparing to mass-derived concentrations of size-selected and counted ammonium sulfate ((NH4)2SO4), ammonium nitrate (NH4NO3), ammonium chloride (NH4Cl), sodium nitrate (NaNO3), and ammonium oxalate ((NH4)2C2O4) particles determined using instruments that measure particle number and size. These measurements demonstrate Nr-particle conversion across the Nr catalysts that is independent of particle size with 98 ± 10 % efficiency for 100-600 nm particle diameters. We also show efficient conversion of particle-phase organic carbon species to CO2 across the instrument's platinum catalyst followed by a nondispersive infrared (NDIR) CO2 detector. However, the application of this method to the atmosphere presents a challenge due to the small signal above background at high ambient levels of common gas-phase carbon compounds (e.g., CO2). We show the Nr system is an accurate particle mass measurement method and demonstrate its ability to calibrate particle mass measurement instrumentation using single-component, laboratory-generated, Nr-containing particles below 2.5 µm in size. In addition we show agreement with mass measurements of an independently calibrated online particle-into-liquid sampler directly coupled to the

  11. Predicting Soil Organic Carbon and Total Nitrogen in the Russian Chernozem from Depth and Wireless Color Sensor Measurements

    Science.gov (United States)

    Mikhailova, E. A.; Stiglitz, R. Y.; Post, C. J.; Schlautman, M. A.; Sharp, J. L.; Gerard, P. D.

    2017-12-01

    Color sensor technologies offer opportunities for affordable and rapid assessment of soil organic carbon (SOC) and total nitrogen (TN) in the field, but the applicability of these technologies may vary by soil type. The objective of this study was to use an inexpensive color sensor to develop SOC and TN prediction models for the Russian Chernozem (Haplic Chernozem) in the Kursk region of Russia. Twenty-one dried soil samples were analyzed using a Nix Pro™ color sensor that is controlled through a mobile application and Bluetooth to collect CIEL*a*b* (darkness to lightness, green to red, and blue to yellow) color data. Eleven samples were randomly selected to be used to construct prediction models and the remaining ten samples were set aside for cross validation. The root mean squared error (RMSE) was calculated to determine each model's prediction error. The data from the eleven soil samples were used to develop the natural log of SOC (lnSOC) and TN (lnTN) prediction models using depth, L*, a*, and b* for each sample as predictor variables in regression analyses. Resulting residual plots, root mean square errors (RMSE), mean squared prediction error (MSPE) and coefficients of determination ( R 2, adjusted R 2) were used to assess model fit for each of the SOC and total N prediction models. Final models were fit using all soil samples, which included depth and color variables, for lnSOC ( R 2 = 0.987, Adj. R 2 = 0.981, RMSE = 0.003, p-value < 0.001, MSPE = 0.182) and lnTN ( R 2 = 0.980 Adj. R 2 = 0.972, RMSE = 0.004, p-value < 0.001, MSPE = 0.001). Additionally, final models were fit for all soil samples, which included only color variables, for lnSOC ( R 2 = 0.959 Adj. R 2 = 0.949, RMSE = 0.007, p-value < 0.001, MSPE = 0.536) and lnTN ( R 2 = 0.912 Adj. R 2 = 0.890, RMSE = 0.015, p-value < 0.001, MSPE = 0.001). The results suggest that soil color may be used for rapid assessment of SOC and TN in these agriculturally important soils.

  12. METHODS FOR THE DETERMINATION OF TOTAL ORGANIC ...

    Science.gov (United States)

    Organic matter in soils and sediments is widely distributed over the earth's surface occurring in almost all terrestrial and aquatic environments (Schnitzer, 1978). Soils and sediments contain a large variety of organic materials ranging from simple sugars and carbohydrates to the more complex proteins, fats, waxes, and organic acids. Important characteristics of the organic matter include their ability to: form water-soluble and water- insoluble complexes with metal ions and hydrous oxides; interact with clay minerals and bind particles together; sorb and desorb both naturally-occurring and anthropogenically-introduced organic compounds; absorb and release plant nutrients; and hold water in the soil environment. As a result of these characteristics, the determination of total organic carbon (a measure of one of the chemical components of organic matter that is often used as an indicator of its presence in a soil or sediment) is an essential part of any site characterization since its presence or absence can markedly influence how chemicals will react in the soil or sediment. Soil and sediment total organic carbon (TOC) determinations are typically requested with contaminant analyses as part of an ecological risk assessment data package. TOC contents may be used qualitatively to assess the nature of the sampling location (e.g., was it a depositional area) or may be used to normalize portions of the analytical chemistry data set (e.g., equilibrium partitioning).

  13. Organ mass measurements

    International Nuclear Information System (INIS)

    Kawamura, H.

    1998-01-01

    The term, anatomical measurements, in the context of this Co-ordinated Research Programme refers to measurements of masses of internal organs, although the human body is composed of internal organs and tissues such as skeleton, muscle, skin and adipose. The mass of an organ containing a radionuclide (source organ), and the mass of a target organ which absorbs energy of the radiation, are essential parameters in the ICRP dosimetric model derived from the MIRD method. Twelve specific organs of interest were proposed at the Coordinated Research Programme Project Formulation Meeting (PFM) in 1988. A slightly different set of thirteen organs with potential significance for radiation protection were selected for study at the Research Co-ordination Meeting held at the Bhabha Atomic Research Centre in 1991. The dimensions of the organs could also be useful information, but were considered unimportant for internal dose assessment. Due to the strong concern about the unified method for collecting organ mass data at the PFM, a guide-line was established stressing the need for organ data from subjects that were healthy and normal, at least until shortly before death, or from sudden death cases, following the Japanese experience. In this report, masses of nine to thirteen organs are presented from seven participating countries. Three participants have also reported the organ masses as fractions of the total body mass

  14. CO 2 Capture Capacity and Swelling Measurements of Liquid-like Nanoparticle Organic Hybrid Materials via Attenuated Total Reflectance Fourier Transform Infrared Spectroscopy

    KAUST Repository

    Park, Youngjune

    2012-01-12

    Novel nanoparticle organic hybrid materials (NOHMs), which are comprised of organic oligomers or polymers tethered to an inorganic nanosized cores of various sizes, have been synthesized, and their solvating property for CO 2 was investigated using attenuated total reflectance (ATR) Fourier transform infrared (FT-IR) spectroscopy. Simultaneous measurements of CO 2 capture capacity and swelling behaviors of polyetheramine (Jeffamine M-2070) and its corresponding NOHMs (NOHM-I-PE2070) were reported at temperatures of (298, 308, 323 and 353) K and CO 2 pressure conditions ranging from (0 to 5.5) MPa. The polymeric canopy, or polymer bound to the nanoparticle surface, showed significantly less swelling behavior with enhanced or comparable CO 2 capture capacity compared to pure unbound polyetheramine. © 2011 American Chemical Society.

  15. An approach to the estimative the DBO and the DQO of residual waters by means of the measure of the total organic carbon

    International Nuclear Information System (INIS)

    Munoz, Horacio; Mejia, Gloria; Chaverra, Marlene; Vasquez, Esmeralda

    2000-01-01

    Using parameters like BOD and COD has normally done the measurement of the contents of biodegradable organic matter present in both water and wastewaters. Since the time required to obtain the first of them is too long for practical purposes plus the fact that precision achieved in analysis results is not too high for both, some troubles are encountered when evaluating pollution loads for different objectives (applying water quality criteria to discharge effluents or designing wastewater treatment facilities) this paper presents the results of a method of estimation of both parameters through the use of the total organic carbon contents of waste waters. Its detection is quick and accurate and could mean the access to a tool with many possibilities in water pollution assessment and waste water treatment control

  16. Deriving an atmospheric budget of total organic bromine using airborne in-situ measurements of brominated hydrocarbons in the Western Pacific during SHIVA

    Science.gov (United States)

    Sala, Stephan; Bönisch, Harald; Keber, Timo; Oram, Dave; Mills, Graham; Engel, Andreas

    2014-05-01

    Halogenated hydrocarbons play a major role as precursors for stratospheric ozone depletion. Released from the surface in the troposphere, the halocarbons reach the stratosphere via transport through the tropical tropopause layer. The contribution of the so called very short lived species (VSLS), having atmospheric lifetimes of less than half a year as sources gases for stratospheric bromine is significant. Source gas observations of long-lived bromine compounds and VSLS have so far not been able to explain the amount of bromine derived in the stratosphere from observations of BrO and modeling of the ratio of BrO to total bromine. Due to the short lifetimes and the high atmospheric variability, the representativeness of the available observations of VSLS source gases remains unclear, as these may vary with region and display seasonal variability. During the SHIVA (Stratospheric Ozone: Halogen Impacts in a Varying Atmosphere) project an extensive dataset with over 700 samples of ambient air of all halogen species relevant for the atmospheric budget of total organic bromine (long lived halocarbons: H-1301, H-1211, H-1202, H-2402 and CH3Br, very short lived substances: CHBr3, CH2Br2, CHBr2Cl, CHBrCl2 and CHBrCl) have been collected from onboard the FALCON aircraft in the West Pacific region. Measurements were performed with the newly developed fully-automated in-situ instrument GHOST-MS (Gas chromatograph for the Observation of Tracers - coupled with a Mass Spectrometer) by the Goethe University of Frankfurt and with the onboard whole-air sampler WASP with subsequent ground based state-of-the-art GC/MS analysis by the University of East Anglia. We will present the datasets, compare these to other observation, derive a bromine budget for the West Pacific and derive an estimate of the amount of bromine from VSLS reaching the stratosphere. Using the mean mixing ratios in the upper troposphere of the halocarbons mentioned above, the calculated budget of the total organic

  17. Correlation between Soil Organic Matter, Total Organic Matter and ...

    African Journals Online (AJOL)

    A total of four sites distributed in different soils of Kelantan State, Malaysia was identified for the study. Soils were collected by depth interval of 0-10cm, 10-20cm and 20-30cm. The correlation of soil organic matter (SOM) content, total organic carbon (TOC) content, water content and soils texture for industrial area at ...

  18. CO 2 Capture Capacity and Swelling Measurements of Liquid-like Nanoparticle Organic Hybrid Materials via Attenuated Total Reflectance Fourier Transform Infrared Spectroscopy

    KAUST Repository

    Park, Youngjune; Shin, Dolly; Jang, Young Nam; Park, Ah-Hyung Alissa

    2012-01-01

    attenuated total reflectance (ATR) Fourier transform infrared (FT-IR) spectroscopy. Simultaneous measurements of CO 2 capture capacity and swelling behaviors of polyetheramine (Jeffamine M-2070) and its corresponding NOHMs (NOHM-I-PE2070) were reported

  19. Defense meteorological satellite measurements of total ozone

    International Nuclear Information System (INIS)

    Lovill, J.E.; Ellis, J.S.; Luther, F.M.; Sullivan, R.J.; Weichel, R.L.

    1992-01-01

    A multichannel filter radiometer (MFR) on Defense Meteorological Satellites (DMS) that measured total ozone on a global-scale from March 1977 - February 1980 is described. The total ozone data measured by the MFR were compared with total ozone data taken by surfaced-based Dobson spectrophotometers. When comparisons were made for five months, the Dobson spectrophotometer measured 2-5% more total ozone than the MFR. Comparisons between the Dobson spectrophotometer and the MFR showed a reduced RMS difference as the comparisons were made at closer proximity. A Northern Hemisphere total ozone distribution obtained from MFR data is presented

  20. Total gaseous mercury and volatile organic compounds measurements at five municipal solid waste disposal sites surrounding the Mexico City Metropolitan Area

    Science.gov (United States)

    de la Rosa, D. A.; Velasco, A.; Rosas, A.; Volke-Sepúlveda, T.

    The daily municipal solid waste (MSW) generation in the Mexico City Metropolitan Area (MCMA) is the highest nationwide (˜26000 ton day -1); this amount is discarded in sanitary landfills and controlled dumps. Information about the type and concentration of potential pollutants contained in landfill gas (LFG) from these MSW disposal sites is limited. This study intends to generate information about the composition of LFG from five MSW disposal sites with different operational characteristics and stages, in order to identify their contribution as potential pollutant sources of total gaseous mercury (TGM) and volatile organic compounds (VOCs). Important methane (CH 4) contents (>55%) in LFG were registered at three of the five sites, while two sites were found in semi-aerobic conditions (CH 4clay cover. High values of the TGM air/LFG ratio were also related to external TGM sources of influence, as a landfill in operation stage located at a highly industrialized area.

  1. Total volatile organic compounds (TVOC) in indoor air quality investigations

    DEFF Research Database (Denmark)

    Mølhave, L.; Clausen, Geo; Berglund, B.

    1997-01-01

    The amount of volatile organic compounds (VOCs) in indoor air, usually called TVOC (total volatile organic compounds), has been measured using different definitions and techniques which yield different results. This report recommends a definition of TVOC referring to a specified range of VOCs...... for characterizing indoor pollution and for improving source control as required from the points of view of health, comfort, energy efficiency and sustainability. (C) Indoor Air (1997)....

  2. Records Management in Organization and Total Quality

    Directory of Open Access Journals (Sweden)

    Fahrettin Özdemirci

    1999-06-01

    Full Text Available In this article the relationship between total quality management and records managemen t are examined. It has also been indicated that the records mana­gement has vita'ly important part for realizing the total quality management approach.

  3. [Total analysis of organic rubber additives].

    Science.gov (United States)

    He, Wen-Xuan; Robert, Shanks; You, Ye-Ming

    2010-03-01

    In the present paper, after middle pressure chromatograph separation using both positive phase and reversed-phase conditions, the organic additives in ethylene-propylene rubber were identified by infrared spectrometer. At the same time, by using solid phase extraction column to maintain the main component-fuel oil in organic additves to avoid its interfering with minor compounds, other organic additves were separated and analysed by GC/Ms. In addition, the remaining active compound such as benzoyl peroxide was identified by CC/Ms, through analyzing acetone extract directly. Using the above mentioned techniques, soften agents (fuel oil, plant oil and phthalte), curing agent (benzoylperoxide), vulcanizing accelerators (2-mercaptobenzothiazole, ethyl thiuram and butyl thiuram), and antiagers (2, 6-Di-tert-butyl-4-methyl phenol and styrenated phenol) in ethylene-propylene rubber were identified. Although the technique was established in ethylene-propylene rubber system, it can be used in other rubber system.

  4. Measurements of total OH reactivity during PROPHET-AMOS 2016

    Science.gov (United States)

    Rickly, P.; Sakowski, J.; Bottorff, B.; Lew, M.; Stevens, P. S.; Sklaveniti, S.; Locoge, N.; Dusanter, S.

    2017-12-01

    As one of the main oxidant in the atmosphere, the hydroxyl radical (OH) initiates the oxidation of volatile organic compounds that can lead to the formation of ozone and secondary organic aerosols. Understanding both the sources and sinks of OH is therefore important to address issues related to air quality and climate change. Measurements of total OH reactivity can provide an important test of our understanding of the OH radical budget. Recent measurements of total reactivity in many environments have been greater than calculated based on the measured concentration of VOCs, suggesting that important OH sinks in these environments are not well characterized. Measurements of total OH reactivity were performed in a forested environment during the PROPHET - AMOS field campaign (Program for Research on Oxidants: PHotochemisty, Emissions, and Transport - Atmospheric Measurements of Oxidants in Summer) using the Comparative Reactivity Method (CRM) and the Total OH Loss Rate Method (TOHLM). The site is characterized by large emissions of isoprene and monoterpenes and low anthropogenic influence. Measurements of total OH reactivity using these two techniques agree to within their respective uncertainties, giving confidence in the measured OH reactivity. In addition, measurements of trace gases (VOCs, NOx, O3) were used to perform a comprehensive apportionment of OH sinks. These measurements are used in a chemical model using the Master Chemical Mechanism to calculate the expected OH reactivity. The results will be compared to previous measurements of total OH reactivity at this site.

  5. LAMBDA p total cross-section measurement

    CERN Multimedia

    CERN PhotoLab

    1970-01-01

    A view of the apparatus used for the LAMBDA p total cross-section measurement at the time of its installation. The hyperons decaying into a proton and a pion in the conical tank in front were detected in the magnet spectrometer in the upper half of the picture. A novel detection technique using exclusively multiwire proportional chambers was employed.

  6. Total performance measurement and management: TPM2

    Energy Technology Data Exchange (ETDEWEB)

    Sheather, G. [University of Technology, Sydney, NSW (Australia)

    1996-10-01

    As the rate of incremental improvement activities and business process re-engineering programs increase, product development times reduce, collaborative endeavours between OEMs and out-sourcing suppliers increase, as agile manufacturing responds to the demands of a global marketplace, the `virtual` organisation is becoming a reality. In this context, customers, partners, suppliers and manufacturers are increasingly separated by field geography, time zone, and availability, but linked by distributed information systems. Measuring and monitoring business performance in this environment requires a entirely different framework and set of key performance indicators (KPIs) usually associated with traditional financial accounting approaches. These approaches are critiqued, then the paper introduces a new concept `Total Performance Measurement Management` (TPM2), to distinguish it from the conventional TPM (Total Productive Management). A model for combining both financial and non-financial KPIs relevant to real-time performance measures stretching across strategic, business unit and operational levels, is presented. The results of the model confirm the hypothesis that it is feasible to develop a TPM2 framework for achieving enterprise wide strategic objectives. (author). 6 tabs., 18 figs., refs.

  7. measurements with a total absorption detector

    International Nuclear Information System (INIS)

    Shibata, Michihiro; Kawade, Kiyoshi; Shindou, Terumasa; Kojima, Yasuaki; Taniguchi, Akihiro; Kawase, Yoichi; Ichikawa, Shin-ichi

    2003-01-01

    For Q β determination, we have developed a newly total absorption detector that can detect almost all radiation from the radioactive nuclei. The detector is composed of large volume and low background twin BGO scintillation detectors. The estimated efficiency is more than two orders of magnitude larger than those of Ge or Si detectors. The Q β s of some fission products of 235 U were successfully measured using an on-line mass separator for the first time (KUR-ISOL). We have proposed the possibility of determination Q β up to about 10 MeV using the detector without the knowledge of the decay scheme. (author)

  8. Characterization and monitoring of total organic chloride vapors

    International Nuclear Information System (INIS)

    Anheier, N.C. Jr.; Evans, J.C. Jr.; Olsen, K.B.

    1992-07-01

    Chemical sensors are being developed intermediate highly selective and broadly selective methods. PNL is developing an optical-emission based TOCl (total organic chlorinated compounds) sensor (Halosnif) which is capable of measuring TOCl in real time on an extracted gas sample over a wide linear dynamic range. Halosnif employs an atomic emission sensor that is broadly selective for any moderately volatile organic hclorinated vapor but does not distinguish between classes of chlorinated compounds. A rf-induced He plasma is used to excite the chlorine atoms, causing light emission at 837.6 nm. The sensitivity ranges from 1-2 ppM up to at least 10,000 ppM. Field tests were conducted at Tinker AFB in areas of high TCE contamination, in two boreholes at Savannah River, and at Hanford CCl 4 vapor extraction system. This sensor is briefly compared with acoustic wave sensors being developed by SNL (PAWS). 4 figs

  9. DEVELOP NEW TOTAL ORGANIC CARBON/SPECIFIC UV ...

    Science.gov (United States)

    The purpose of this project is to provide a total organic carbon (TOC)/specific ultraviolet absorbance (SUVA) method that will be used by the Office of Ground Water and Drinking Water (OGWDW) to support monitoring requirements of the Stage 2 Disinfectant/Disinfection By-products (D/DBP) Rule. The Stage 2 Rule requires that enhanced water treatment be used if the source water is high in aquatic organic matter prior to the application of a disinfectant. Disinfectants (chlorine, ozone, etc.) are used in the production of drinking water in order to reduce the risk of microbial disease. These disinfectants react with the organic material that is naturally present in the source water to form disinfection by-products (DBPs). Exposure to some of these by-products may pose a long term health risk. The number and nature of DBPs make it impossible to fully characterize all of the by-products formed during the treatment of drinking water and it is more cost effective to reduce formation of DBPs than to remove them from the water after they are formed. Two measurements (TOC and SUVA) are believed to be predictive of the amount of by-products that can be formed during the disinfection of drinking water and are considered to be surrogates for DBP precursors. SUVA is calculated as the ultraviolet absorption at 254nm (UV254) in cm-1 divided by the mg/L dissolved organic carbon (DOC) concentration (measured after filtration of the water through a 0.45um pore-diameter filte

  10. Supercritical Water Oxidation Total Organic Carbon (TOC) Analysis

    Science.gov (United States)

    The work presented here is the evaluation of the modified wet‐oxidation method described as Supercritical Water Oxidation (SCWO) for the analysis of total organic carbon (TOC) in very difficult oil/gas produced water sample matrices.

  11. Mini Total Organic Carbon Analyzer (miniTOCA)

    Data.gov (United States)

    National Aeronautics and Space Administration — The objective of this development is to create a prototype hand-held, 1 to 2 liter size battery-powered Total Organic Carbon Analyzer (TOCA). The majority of...

  12. ORGANIC CARBON AND TOTAL NITROGEN IN THE DENSIMETRIC FRACTIONS OF ORGANIC MATTER UNDER DIFFERENT SOIL MANAGEMEN

    Directory of Open Access Journals (Sweden)

    MARCELO RIBEIRO VILELA PRADO

    2016-01-01

    Full Text Available The evaluation of land use and management by the measurement of soil organic matter and its fractions has gained attention since it helps in the understanding of the dynamics of their contribution to soil productivity, especially in tropical environments. This study was conducted in the municipality of Colorado do Oeste, state of Rondônia, Brazil and its aim was to determinethe quantity of organic carbon and total nitrogen in the light and heavy fractions of organic matter in the surface layers of a typic hapludalf under different land use systems: Native Forest: open evergreen forest, reference environment; Agroforestry System 1: teak (Tectona grandis LF and kudzu (Pueraria montana; Agroforestry System 2: coffee (Coffea canephora, marandu palisade grass (Brachiaria brizantha cv. Marandu, “pinho cuiabano” (Parkia multijuga, teak and kudzu.; Agroforestry System 3: teak and cocoa (Theobroma cacao; Silvopasture System: teak, cocoa and marandu palisade grass; and Extensive Grazing System: marandu palisade grass. The experimental design was a randomized block in split-split plots (use systems versus soil layers of 0-0.05 and 0.05-0.10 m with three replications. The results showed that relative to Native Forest, the Agroforestry System 2 had equal- and greater amounts of organic carbon and total nitrogen respectively (light and heavy fractions in the soil organic matter, with the light fraction being responsible for storage of approximately 45% and 70% of the organic carbon and total nitrogen, respectively. Therefore, the light densimetric fraction proved to be useful in the early identification of the general decline of the soil organic matter in the land use systems evaluated.

  13. Apparatus for measuring total flow in pipes

    International Nuclear Information System (INIS)

    Matthews, H.

    1986-01-01

    To obtain a sample representative of the total flow in a pipe over a given period a Pitot tube is located in the pipe and connected to a collector outside the pipe. The collector is pressurised to a pressure substantially equal to the static head of the flow in the pipe via a line. Liquid is discharged from a collector to a container which is vented to atmosphere. (author)

  14. Measurement of total body radioactivity in man

    International Nuclear Information System (INIS)

    Naversten, Y.

    1982-01-01

    Techniques for the determination of whole-body radioactivity in man using uncollimated NaI(Tl) detectors have been studied. Geometrical effects and photon attenuation effects due to the different shapes of humans as well as due to varying in-vivo radioactivity distributions have been evaluated particularly for scanning-bed geometries and the chair geometry. Theoretically it is shown that the attenuation effects are generally dominating, for full-energy-peak pulse-range methods. For the application in radiation protection a cheap and simple chair-geometry unit has been constructed and used at various places distantly from the home-laboratory, for studies of body activity of Cs-137 in northern Sweden. High body activities were found particularly in reindeer-breeding Lapps. The elimination rate of Cs-137 in man was studied in the stationary whole-body counter in Lund as well as with the field-system. For the study of the performances at low and high photon energies clinical applications of methods for gastro-intestinal absorption of vitamin B12 (Co-57; 122 keV) and total body potassium determination (K-40; 1.46 MeV, K-42; 1.52 MeV) have been evaluated. Theoretical and experimental results as well as experiences of applications in radiation protection and medicine show that the scanning-bed geometry effectively evens out redistributional effects. For optimum results, however, scatter-energy pulse-ranges rather than full-energy-peak ranges should be used. (Auth.)

  15. Perioperative blood saving measures in total hip and knee arthroplasty

    NARCIS (Netherlands)

    Horstmann, W.G.

    2011-01-01

    This dissertation explores and discusses different aspects of blood loss and blood-saving measures in total hip and knee arthroplasty. Background: Worldwide, approximately 1 million total hip and 1 million total knee prostheses are implanted each year. Total hip arthroplasty and total

  16. Efficiency measures for industrial organization

    NARCIS (Netherlands)

    ten Raa, Thijs; Ray, Subhash C.; Kumbhakar, Subal C.; Dua, Pami

    2015-01-01

    The aim of the paper is to measure the efficiency of an industry, and to decompose it in firm efficiencies—which indicate how close firms approximate best practices—and an organization efficiency—which indicates the degree of optimality of the number of firms and their distribution. The latter

  17. Determination of total organic phosphorus in samples of mineral soils

    Directory of Open Access Journals (Sweden)

    Armi Kaila

    1962-01-01

    Full Text Available In this paper some observations on the estimation of organic phosphorus in mineral soils are reported. The fact is emphasized that the accuracy of all the methods available is relatively poor. Usually, there are no reasons to pay attention to differences less than about 20 ppm. of organic P. Analyses performed on 345 samples of Finnish mineral soils by the extraction method of MEHTA et. al. (10 and by a simple procedure adopted by the author (successive extractions with 4 N H2SO4 and 0.5 N NaOH at room temperature in the ratio of 1 to 100 gave, on the average, equal results. It seemed to be likely that the MEHTA method removed the organic phosphorus more completely than did the less vigorous method, but in the former the partial hydrolysis of organic phosphorus compounds tends to be higher than in the latter. An attempt was made to find out whether the differences between the respective values for organic phosphorus obtained by an ignition method and the simple extraction method could be connected with any characteristics of the soil. No correlation or only a low correlation coefficient could be calculated between the difference in the results of these two methods and e. g. the pH-value, the content of clay, organic carbon, aluminium and iron soluble in Tamm’s acid oxalate, the indicator of the phosphate sorption capacity, or the »Fe-bound» inorganic phosphorus, respectively. The absolute difference tended to increase with an increase in the content of organic phosphorus. For the 250 samples of surface soils analyzed, the ignition method gave values which were, on the average, about 50 ppm. higher than the results obtained by the extraction procedure. The corresponding difference for the 120 samples from deeper layers was about 20 ppm of organic P. The author recommends, for the present, the determination of the total soil organic phosphorus as an average of the results obtained by the ignition method and the extraction method.

  18. Total organic carbon in aggregates as a soil recovery indicator

    Science.gov (United States)

    Luciene Maltoni, Katia; Rodrigues Cassiolato, Ana Maria; Amorim Faria, Glaucia; Dubbin, William

    2015-04-01

    The soil aggregation promotes physical protection of organic matter, preservation of which is crucial to improve soil structure, fertility and ensure the agro-ecosystems sustainability. The no-tillage cultivation system has been considered as one of the strategies to increase total soil organic carbono (TOC) contents and soil aggregation, both are closely related and influenced by soil management systems. The aim of this study was to evaluate the distribution of soil aggregates and the total organic carbon inside aggregates, with regard to soil recovery, under 3 different soil management systems, i.e. 10 and 20 years of no-tillage cultivation as compared with soil under natural vegetation (Cerrado). Undisturbed soils (0-5; 5-10; and 10-20 cm depth) were collected from Brazil, Central Region. The soils, Oxisols from Cerrado, were collected from a field under Natural Vegetation-Cerrado (NV), and from fields that were under conventional tillage since 1970s, and 10 and 20 years ago were changed to no-tillage cultivation system (NT-10; NT-20 respectively). The undisturbed samples were sieved (4mm) and the aggregates retained were further fractionated by wet sieving through five sieves (2000, 1000, 500, 250, and 50 μm) with the aggregates distribution expressed as percentage retained by each sieve. The TOC was determined, for each aggregate size, by combustion (Thermo-Finnigan). A predominance of aggregates >2000 μm was observed under NV treatment (92, 91, 82 %), NT-10 (64, 73, 61 %), and NT-20 (71, 79, 63 %) for all three depths (0-5; 5-10; 10-20 cm). In addition greater quantities of aggregates in sizes 1000, 500, 250 and 50 μm under NT-10 and NT-20 treatments, explain the lower aggregate stability under these treatments compared to the soil under NV. The organic C concentration for NV in aggregates >2000 μm was 24,4; 14,2; 8,7 mg/g for each depth (0-5; 5-10; 10-20 cm, respectively), higher than in aggregates sized 250-50 μm (7,2; 5,5; 4,4 mg/g) for all depths

  19. Positron interactions with water–total elastic, total inelastic, and elastic differential cross section measurements

    International Nuclear Information System (INIS)

    Tattersall, Wade; Chiari, Luca; Machacek, J. R.; Anderson, Emma; Sullivan, James P.; White, Ron D.; Brunger, M. J.; Buckman, Stephen J.; Garcia, Gustavo; Blanco, Francisco

    2014-01-01

    Utilising a high-resolution, trap-based positron beam, we have measured both elastic and inelastic scattering of positrons from water vapour. The measurements comprise differential elastic, total elastic, and total inelastic (not including positronium formation) absolute cross sections. The energy range investigated is from 1 eV to 60 eV. Comparison with theory is made with both R-Matrix and distorted wave calculations, and with our own application of the Independent Atom Model for positron interactions

  20. Applying total quality management concepts to public health organizations.

    Science.gov (United States)

    Kaluzny, A D; McLaughlin, C P; Simpson, K

    1992-01-01

    Total quality management (TQM) is a participative, systematic approach to planning and implementing a continuous organizational improvement process. Its approach is focused on satisfying customers' expectations, identifying problems, building commitment, and promoting open decision-making among workers. TQM applies analytical tools, such as flow and statistical charts and check sheets, to gather data about activities within an organization. TQM uses process techniques, such as nominal groups, brainstorming, and consensus forming to facilitate communication and decision making. TQM applications in the public sector and particularly in public health agencies have been limited. The process of integrating TQM into public health agencies complements and enhances the Model Standards Program and assessment methodologies, such as the Assessment Protocol for Excellence in Public Health (APEX-PH), which are mechanisms for establishing strategic directions for public health. The authors examine the potential for using TQM as a method to achieve and exceed standards quickly and efficiently. They discuss the relationship of performance standards and assessment methodologies with TQM and provide guidelines for achieving the full potential of TQM in public health organizations. The guidelines include redefining the role of management, defining a common corporate culture, refining the role of citizen oversight functions, and setting realistic estimates of the time needed to complete a task or project. PMID:1594734

  1. a locally adapted functional outcome measurement score for total

    African Journals Online (AJOL)

    Results and success of total hip arthroplasty are often measured using a functional outcome scoring system. Most current scores were developed in Europe and. North America (1-3). During the evaluation of a Total. Hip Replacement (THR) project in Ouagadougou,. Burkina Faso (4) it was felt that these scores were not.

  2. Maximum total organic carbon limit for DWPF melter feed

    International Nuclear Information System (INIS)

    Choi, A.S.

    1995-01-01

    DWPF recently decided to control the potential flammability of melter off-gas by limiting the total carbon content in the melter feed and maintaining adequate conditions for combustion in the melter plenum. With this new strategy, all the LFL analyzers and associated interlocks and alarms were removed from both the primary and backup melter off-gas systems. Subsequently, D. Iverson of DWPF- T ampersand E requested that SRTC determine the maximum allowable total organic carbon (TOC) content in the melter feed which can be implemented as part of the Process Requirements for melter feed preparation (PR-S04). The maximum TOC limit thus determined in this study was about 24,000 ppm on an aqueous slurry basis. At the TOC levels below this, the peak concentration of combustible components in the quenched off-gas will not exceed 60 percent of the LFL during off-gas surges of magnitudes up to three times nominal, provided that the melter plenum temperature and the air purge rate to the BUFC are monitored and controlled above 650 degrees C and 220 lb/hr, respectively. Appropriate interlocks should discontinue the feeding when one or both of these conditions are not met. Both the magnitude and duration of an off-gas surge have a major impact on the maximum TOC limit, since they directly affect the melter plenum temperature and combustion. Although the data obtained during recent DWPF melter startup tests showed that the peak magnitude of a surge can be greater than three times nominal, the observed duration was considerably shorter, on the order of several seconds. The long surge duration assumed in this study has a greater impact on the plenum temperature than the peak magnitude, thus making the maximum TOC estimate conservative. Two models were used to make the necessary calculations to determine the TOC limit

  3. Total ozone retrieval from satellite multichannel filter radiometer measurements

    International Nuclear Information System (INIS)

    Lovill, J.E.; Sullivan, T.J.; Weichel, R.L.; Ellis, J.S.; Huebel, J.G.; Korver, J.; Weidhaas, P.P.; Phelps, F.A.

    1978-01-01

    A total ozone retrieval model has been developed to process radiance data gathered by a satellite-mounted multichannel filter radiometer (MFR). Extensive effort went into theoretical radiative transfer modeling, a retrieval scheme was developed, and the technique was applied to the MFR radiance measurements. The high quality of the total ozone retrieval results was determined through comparisons with Dobson measurements. Included in the report are global total ozone maps for 20 days between May 12 and July 5, 1977. A comparison of MFR results for 13 days in June 1977 with Dobson spectrophotometer measurements of ozone for the same period showed good agreement: there was a root-mean-square difference of 6.2% (equivalent to 20.2 m.atm.cm). The estimated global total ozone value for June 1977 (296 m.atm.cm) was in good agreement with satellite backscatter ultraviolet data for June 1970 (304 m.atm.cm) and June 1971

  4. Progress on FP13 Total Cross Section Measurements Capability

    Energy Technology Data Exchange (ETDEWEB)

    Ullmann, John Leonard [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Couture, Aaron Joseph [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Koehler, Paul E. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Mocko, Michal [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Mosby, Shea Morgan [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Wender, Stephen Arthur [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-09-26

    An accurate knowledge of the neutron capture cross section is important for many applications. Experimental measurements are important since theoretical calculations of capture have been notoriously difficult, with the ratio of measured to calculated cross sections often a factor of 2 or more in the 10 keV to 1 MeV region. However, a direct measurement of capture cannot be made on many interesting radioactive nuclides because of their short half-life or backgrounds caused by their nuclear decay. On the other hand, neutron transmission measurements of the total cross section are feasible for a wide range of radioactive nuclides since the detectors are far from the sample, and often are less sensitive to decay radiation. The parameters extracted from a total cross section measurement, which include the average resonance spacing, the neutron strength function, and the average total radiation width, (Γγ), provide tight constraints on the calculation of the capture cross section, and when applied produce much more accurate results. These measurements can be made using the intense epithermal neutron flux at the Lujan Center on relatively small quantities of target material. It was the purpose of this project to investigate and develop the capability to make these measurements. A great deal of progress was made towards establishing this capability during 2016, including setting up the flight path and obtaining preliminary results, but more work remains to be done.

  5. Determination of total ozone from DMSP multichannel filter radiometer measurements

    International Nuclear Information System (INIS)

    Luther, F.M.; Weichel, R.L.

    1992-01-01

    The multichannel filter radiometer (MFR) infrared sensor was first flown in 1977 on a Defense Meteorological Satellite Program (DMSP) Block 5D series satellite operated by the US Air Force. The first four satellites in this series carried MFR sensors from which total atmospheric column ozone amounts may be derived. The MFR sensor was the first cross-track scanning sensor capable of measuring ozone. MFR sensor infrared measurements are taken day and night. The satellites are in polar sun-synchronous orbits providing daily global coverage. The series of four sensors spans a data period of nearly three years. The MFR sensor measures infrared radiances for 16 channels. Total ozone amounts are determined from sets of radiance measurements using an empirical relationship that is developed using linear regression analysis. Total ozone is modeled as a linear combination of terms involving functions of the MFR radiances for four channels (1, 3, 7 and 16) and the secant of the zenith angle. The MFR scans side to side in discrete steps of 40. The MFR sensor takes infrared radiance measurements at 25 cross-track scanning locations every 32 seconds. The instrument could take a theoretical maximum of 67,500 measurements per day, although typically 35,000 - 45,000 measurements are taken per day

  6. Neutron total cross section measurements on 249Cf

    International Nuclear Information System (INIS)

    Carlton, R.F.; Harvey, J.A.; Hill, N.W.; Pandey, M.S.; Benjamin, R.W.

    1979-01-01

    Neutron total cross section measurements were performed on a sample of 249 Cf (5.65 mg total weight) with the ORELA as a source of pulsed neutrons. The sample, the inverse thickness of which was 1542 barns/atom, consisted of 85.3% 249 Cf and 14.4% 249 Bk, and was cooled to liquid nitrogen temperature. Analyses were also made of data from a thin sample (l/n = 17430) of 65% 249 Cf in the region of the large fission resonance at 0.7 eV. Fifty-five resonances in 249 Cf were observed and analyzed over the energy range 0.1 eV to 90 eV by use of an R-matrix multilevel formalism. The resonance parameters obtained were used to determine the level spacing and the s-wave neutron and fission strength functions. Thermal total cross section measurements were also performed. 5 figures, 3 tables

  7. Comparative evaluation of organic and inorganic fertilizers on total ...

    African Journals Online (AJOL)

    user

    2013-05-01

    May 1, 2013 ... livestock. New food uses of cassava include flour in gluten free .... The alkaline pictrate method of Sarkiyayi and Agar (2010) was used to determine .... marionberry, strawberry, and corn grown using organic, and sustainable ...

  8. Total cross-section measurements progress in nuclear physics

    CERN Document Server

    Giacomelli, G; Mulvey, J H

    2013-01-01

    Total Cross-Section Measurements discusses the cross-sectional dimensions of elementary hadron collisions. The main coverage of the book is the resonance and high energy area of the given collision. A section of the book explains in detail the characteristic of a resonance region. Another section is focused on the location of the high energy region of collision. Parts of the book define the meaning of resonance in nuclear physics. Also explained are the measurement of resonance and the identification of the area where the resonance originates. Different experimental methods to measure the tota

  9. Total observed organic carbon (TOOC in the atmosphere: a synthesis of North American observations

    Directory of Open Access Journals (Sweden)

    C. L. Heald

    2008-04-01

    Full Text Available Measurements of organic carbon compounds in both the gas and particle phases made upwind, over and downwind of North America are synthesized to examine the total observed organic carbon (TOOC in the atmosphere over this region. These include measurements made aboard the NOAA WP-3 and BAe-146 aircraft, the NOAA research vessel Ronald H. Brown, and at the Thompson Farm and Chebogue Point surface sites during the summer 2004 ICARTT campaign. Both winter and summer 2002 measurements during the Pittsburgh Air Quality Study are also included. Lastly, the spring 2002 observations at Trinidad Head, CA, surface measurements made in March 2006 in Mexico City and coincidentally aboard the C-130 aircraft during the MILAGRO campaign and later during the IMPEX campaign off the northwestern United States are incorporated. Concentrations of TOOC in these datasets span more than two orders of magnitude. The daytime mean TOOC ranges from 4.0 to 456 μgC m−3 from the cleanest site (Trinidad Head to the most polluted (Mexico City. Organic aerosol makes up 3–17% of this mean TOOC, with highest fractions reported over the northeastern United States, where organic aerosol can comprise up to 50% of TOOC. Carbon monoxide concentrations explain 46 to 86% of the variability in TOOC, with highest TOOC/CO slopes in regions with fresh anthropogenic influence, where we also expect the highest degree of mass closure for TOOC. Correlation with isoprene, formaldehyde, methyl vinyl ketone and methacrolein also indicates that biogenic activity contributes substantially to the variability of TOOC, yet these tracers of biogenic oxidation sources do not explain the variability in organic aerosol observed over North America. We highlight the critical need to develop measurement techniques to routinely detect total gas phase VOCs, and to deploy comprehensive suites of TOOC instruments in diverse environments to quantify the ambient evolution of organic carbon from source

  10. Beyond "The Total Organization": A Graduate-Level Simulation

    Science.gov (United States)

    Kane, Kathleen R.; Goldgehn, Leslie A.

    2011-01-01

    This simulation is designed to help students understand the complexity of organizational life and learn how to navigate a work world of chaos, conflict, and uncertainty. This adaptation and update of an exercise by Cohen, Fink, Gadon, and Willits has been a successful addition to MBA and EMBA courses. The participants must self-organize, choose…

  11. Secondary standard neutron detector for measuring total reaction cross sections

    International Nuclear Information System (INIS)

    Sekharan, K.K.; Laumer, H.; Gabbard, F.

    1975-01-01

    A neutron detector has been constructed and calibrated for the accurate measurement of total neutron-production cross sections. The detector consists of a polyethylene sphere of 24'' diameter in which 8- 10 BF 3 counters have been installed radially. The relative efficiency of this detector has been determined for average neutron energies, from 30 keV to 1.5 MeV by counting neutrons from 7 Li(p,n) 7 Be. By adjusting the radial positions of the BF 3 counters in the polyethylene sphere the efficiency for neutron detection was made nearly constant for this energy range. Measurement of absolute efficiency for the same neutron energy range has been done by counting the neutrons from 51 V(p,n) 51 Cr and 57 Fe(p,n) 57 Co reactions and determining the absolute number of residual nuclei produced during the measurement of neutron yield. Details of absolute efficiency measurements and the use of the detector for measurement of total neutron yields from neutron producing reactions such as 23 Na(p,n) 23 Mg are given

  12. Side-by-side comparison of techniques for analyzing organic acids, total organic carbon, and anions. Final report

    International Nuclear Information System (INIS)

    Byers, W.A.; Richards, J.; Silva, H.; Miller, M.R.; Palino, G.F.; Wall, P.S.

    1986-09-01

    The objective of this project was to compare the organic acids sampling and analysis methods of Westinghouse and NWT Corporation. Sampling was performed at three sites, chosen to represent units with high, intermediate and low levels of organic contamination. To check the precision of each method, concurrent sampling was employed. To check the accuracy of each method, additions of standard organic solutions were made at one of the sites. Inorganic anions were also analyzed at each site by each contractor. Theoretical values of cation conductivity were calculated from organic and inorganic analytical data and compared to values measured onsite at the time of sampling. Total organic carbon (TOC) analyses were performed to evaluate different instruments and sampling techniques, as well as provide additional information on the relationship between TOC and organic acids concentrations. It was concluded that either of the organic acid sampling/analysis techniques used by the contractors can produce reliable results. TOC samples lose organics content with storage time and should be analyzed no later than one week after they are taken; if at all possible, they should be stored in a refrigerated condition. State-of-the art techniques for TOC sampling and analysis can produce results varying by 20 to 50 ppB for levels in the range of 50 to 120 ppB; any proposed limits for TOC should be reviewed in that light. Results of anion analyses are quite sensitive to sampling and analytical techniques. Reasonable agreement between calculated and measured values of cation conductivity suggests that both contractors had accurately determined all major anionic species

  13. Total OH Reactivity Measurements in the Boreal Forest

    Science.gov (United States)

    Praplan, A. P.; Hellén, H.; Hakola, H.; Hatakka, J.

    2015-12-01

    INTRODUCTION Atmospheric total OH reactivity (Rtotal) can be measured (Kovacs and Brune, 2001; Sinha et al., 2008) or it can be calculated according to Rtotal = ∑i kOH+X_i [Xi] where kOH+X_i corresponds to the reaction rate coefficient for the reaction of OH with a given compound Xi and [Xi] its concentration. Studies suggest that in some environments a large fraction of missing reactivity, comparing calculated Rtotal with ambient total OH reactivity measurements (Di Carlo et al., 2004; Hofzumahaus et al., 2009). In this study Rtotal has been measured using the Comparative Reactivity Method (Sinha et al., 2008). Levels of the reference compound (pyrrole, C4H5N) are monitored by gas chromatography every 2 minutes and Rtotal is derived from the difference of reactivity between zero and ambient air. RESULTS Around 36 hours of preliminary total OH reactivity data (30 May until 2 June 2015) are presented in Fig. 1. Its range matches previous studies for this site (Nölscher et al., 2012; Sinha et al., 2010) and is similar to values in another pine forest (Nakashima et al., 2014). The setup used during the period presented here has been updated and more recent data will be presented, as well as a comparison with calculated OH reactivity from measured individual species. ACKNOWLEDGEMENTS This work was supported by Academy of Finland (Academy Research Fellowship No. 275608). The authors acknowledge Juuso Raine for technical support. REFERENCES Di Carlo et al. (2004). Science 304, 722-725.Hofzumahaus et al. (2009). Science 324, 1702-1704.Kovacs and Brune (2001). J. Atmos. Chem. 39, 105-122.Nakashima et al. (2014). Atmos. Env. 85, 1-8.Nölscher et al. (2012). Atmos. Chem. Phys. 12, 8257-8270.Sinha et al. (2008). Atmos. Chem. Phys. 8, 2213-2227.Sinha et al. (2010). Environ. Sci. Technol. 44, 6614-6620.

  14. Measuring performance improvement: total organizational commitment or clinical specialization.

    Science.gov (United States)

    Caron, Aleece; Jones, Paul; Neuhauser, Duncan; Aron, David C

    2004-01-01

    Resources for hospitals are limited when they are faced with multiple publicly reported performance measures as tools to assess quality. The leadership in these organizations may choose to focus on 1 or 2 of these outcomes. An alternative approach is that the leadership may commit resources or create conditions that result in improved quality over a broad range of measures. We used aggregated data on mortality, length of stay, and obstetrical outcomes from Greater Cleveland Health Quality Choice data to test these theories. We used Pearson correlation analysis to determine of outcomes were correlated with one another. We used repeated-measures ANOVA to determine if an association existed between outcome and time and outcome and hospital. All of the outcomes across all hospitals demonstrate a trend of overall improvement. Both the Pearson and ANOVA result support the hypothesis for the organization-wide approach to quality improvement. Hospital that make improvements in one clinical area trend to make improvements in others. Hospitals that produce improvements in limited clinical or administrative areas may not have completely adopted CQI into their culture or may not have yet realized the benefits of their organizational commitments, but use some of the concepts to improve quality outcomes.

  15. Total Quality Management – A Way to Manage Organizations Centred on Quality

    Directory of Open Access Journals (Sweden)

    Vasile Dinu

    2017-11-01

    Full Text Available Following the consolidation and maturation of quality management, the evolution of this concept has demonstrated that its most advanced form has become Total Quality Management (TQM. Total Quality Management is a way of leading quality-centred organizations, as this is the main driving force that can direct the organization on the way to excellence in business. At the same time, it is based on the participation of all members, pursuing the efficiency of the long-term activity, leading to the effective satisfaction of the client, as well as to the benefits for all members of organization and for society. Total Quality Management is an approach that aims to continuously improve quality and performance to meet or exceed customer expectations. This can be accomplished by integrating all the functions and performance-related processes in a company. TQM targets all the quality improvement measures used by a company, including quality design and development, control, management, continuous improvement and quality assurance. In other words, TQM considers all quality measures at all levels and compartments that involve all employees in order to obtain long-term benefits

  16. Online total organic carbon (TOC) monitoring for water and wastewater treatment plants processes and operations optimization

    Science.gov (United States)

    Assmann, Céline; Scott, Amanda; Biller, Dondra

    2017-08-01

    Organic measurements, such as biological oxygen demand (BOD) and chemical oxygen demand (COD) were developed decades ago in order to measure organics in water. Today, these time-consuming measurements are still used as parameters to check the water treatment quality; however, the time required to generate a result, ranging from hours to days, does not allow COD or BOD to be useful process control parameters - see (1) Standard Method 5210 B; 5-day BOD Test, 1997, and (2) ASTM D1252; COD Test, 2012. Online organic carbon monitoring allows for effective process control because results are generated every few minutes. Though it does not replace BOD or COD measurements still required for compliance reporting, it allows for smart, data-driven and rapid decision-making to improve process control and optimization or meet compliances. Thanks to the smart interpretation of generated data and the capability to now take real-time actions, municipal drinking water and wastewater treatment facility operators can positively impact their OPEX (operational expenditure) efficiencies and their capabilities to meet regulatory requirements. This paper describes how three municipal wastewater and drinking water plants gained process insights, and determined optimization opportunities thanks to the implementation of online total organic carbon (TOC) monitoring.

  17. Radioimmunological measurements of total LH in sheep pituitary cells

    International Nuclear Information System (INIS)

    McIntosh, R.P.; McIntosh, J.E.A.

    1983-01-01

    Procedures commonly used to extract LH from pituitary cells in order to measure total cell content were compared in four cell preparations. It was shown in 81 samples of cells suspended in 1 mM EDTA or 50 mM NaHCO 3 that after freezing and thawing folloqwed by any of a variety of treatments, there were no significant differences in the amounts of LH measured by RIA relative to the arbitrarily chosen reference treatment of vigorous pipetting. The additional treatments were multiple freezing and thawing, homogenisation, sonication, homogenisation in 25-100 mM Na 2 CO 3 folloqwed by rapid neutralisation, or none. The consistency of the results suggested that the same cellular pools of LH were being made accessible for measurement with all treatments. However, use of the more vigorous conditions of 1-2.5 M urea, 1% Triton X-100, or sonication on ice in 100 mM Na 2 CO 3 decreased the amount of measurable hormone presumably due to its modification. In two cell preparations, homogenisation of cells in 100 mM Na 2 CO 3 produced and additional 45% of measurable LH not accessible using other treatments nor from the source material in two other preparations. (author)

  18. Total expenditures per patient in hospital-owned and physician-owned physician organizations in California.

    Science.gov (United States)

    Robinson, James C; Miller, Kelly

    Hospitals are rapidly acquiring medical groups and physician practices. This consolidation may foster cooperation and thereby reduce expenditures, but also may lead to higher expenditures through greater use of hospital-based ambulatory services and through greater hospital pricing leverage against health insurers. To determine whether total expenditures per patient were higher in physician organizations (integrated medical groups and independent practice associations) owned by local hospitals or multihospital systems compared with groups owned by participating physicians. Data were obtained on total expenditures for the care provided to 4.5 million patients treated by integrated medical groups and independent practice associations in California between 2009 and 2012. The patients were covered by commercial health maintenance organization (HMO) insurance and the data did not include patients covered by commercial preferred provider organization (PPO) insurance, Medicare, or Medicaid. Total expenditures per patient annually, measured in terms of what insurers paid to the physician organizations for professional services, to hospitals for inpatient and outpatient procedures, to clinical laboratories for diagnostic tests, and to pharmaceutical manufacturers for drugs and biologics. Annual expenditures per patient were compared after adjusting for patient illness burden, geographic input costs, and organizational characteristics. Of the 158 organizations, 118 physician organizations (75%) were physician-owned and provided care for 3,065,551 patients, 19 organizations (12%) were owned by local hospitals and provided care for 728,608 patients, and 21 organizations (13%) were owned by multihospital systems and provided care for 693,254 patients. In 2012, physician-owned physician organizations had mean expenditures of $3066 per patient (95% CI, $2892 to $3240), hospital-owned physician organizations had mean expenditures of $4312 per patient (95% CI, $3768 to $4857), and

  19. A new automated colorimetric method for measuring total oxidant status.

    Science.gov (United States)

    Erel, Ozcan

    2005-12-01

    To develop a new, colorimetric and automated method for measuring total oxidation status (TOS). The assay is based on the oxidation of ferrous ion to ferric ion in the presence of various oxidant species in acidic medium and the measurement of the ferric ion by xylenol orange. The oxidation reaction of the assay was enhanced and precipitation of proteins was prevented. In addition, autoxidation of ferrous ion present in the reagent was prevented during storage. The method was applied to an automated analyzer, which was calibrated with hydrogen peroxide and the analytical performance characteristics of the assay were determined. There were important correlations with hydrogen peroxide, tert-butyl hydroperoxide and cumene hydroperoxide solutions (r=0.99, Ptotal antioxidant capacity (TAC) (r=-0.66 Ptotal oxidant status.

  20. Measuring and understanding total dissolved gas pressure in groundwater

    Science.gov (United States)

    Ryan, C.; Roy, J. W.; Randell, J.; Castellon, L.

    2009-05-01

    Since dissolved gases are important to a number of aspects of groundwater (e.g. age dating, active or passive bioremediation, greenhouse gas fluxes, understanding biogeochemical processes involving gases, assessing potential impacts of coal bed methane activities), accurate concentration measurements, and understanding of their subsurface behaviour are important. Researchers have recently begun using total dissolved gas pressure (TGP) sensor measurements, more commonly applied for surface water monitoring, in concert with gas composition analyses to estimate more accurate groundwater gas concentrations in wells. We have used hydraulic packers to isolate the well screens where TDP is being measured, and pump tests to indicate that in-well degassing may reduce TDG below background groundwater levels. Thus, in gas-charged groundwater zones, TGPs can be considerably underestimated in the absence of pumping or screen isolation. We have also observed transient decreased TGPs during pumping that are thought to result from ebullition induced when the water table or water level in the well is lowered below a critical hydrostatic pressure.

  1. Measurement capabilities of the Bendix Metrology Organization

    International Nuclear Information System (INIS)

    Barnes, L.M.

    1984-01-01

    The purpose of this manual is to communicate the measurement and calibration capabilities of the Metrology Organization of the Bendix Kansas City Division. Included is a listing of the measurement types and ranges available, and the accuracies normally attainable under conditions at the Kansas City Division. Also described are currently used standards and measurement devices. The manual is divided into four major sections, each describing a broad general area of measurement: mechanical; environmental, gas, liquid; electrical; and optical and radiation

  2. Measuring and controlling method for organic impurities

    International Nuclear Information System (INIS)

    Aizawa, Motohiro; Igarashi, Hiroo

    1995-01-01

    The present invention concerns measurement and control for organic impurities contained in ultrapurified water for use in a nuclear power plant. A specimen containing organic impurities leached out of anionic exchange resins and cationic exchange resins is introduced to an organic material decomposing section to decompose organic impurities into organic carbon and other decomposed products. Sulfate ions, nitrate ions, nitrite ions and carbon dioxide are produced by the decomposition of the organic impurities. As a next step, carbon dioxide in the decomposed products is separated by deaerating with a nitrogen gas or an argon gas and then a TOC concentration is measured by a non-dispersion-type infrared spectrometer. Further, a specimen from which carbon dioxide was separated is introduced to a column filled with ion exchange resins and, after concentrating inorganic ion impurities, the inorganic ion impurities are identified by using a measuring theory of an ion chromatographic method of eluting and separating inorganic ion impurities and detecting them based on the change of electroconductivity depending on the kinds of the inorganic ion impurities. Organic impurities can be measured and controlled, to improve the reliability of water quality control. (N.H.)

  3. Evaluation of robustness in the validation of total organic carbon (TOC) methodology

    International Nuclear Information System (INIS)

    Benedetti, Stella; Monteiro, Elisiane G.; Almeida, Erika V.; Oliveira, Ideli M.; Cerqueira Filho, Ademar C.; Mengatti, Jair; Fukumori, Neuza T.O.; Matsuda, Margareth M.N.

    2009-01-01

    Water is used in many steps of production and quality control as raw material for reagent preparation or dilution of solutions and for cleaning apparatus and room areas in the pharmaceutical industry, including radiopharmaceutical plants. Regulatory requirements establish specifications of purified water for different purposes. The quality of water is essential to guarantee the safe utilization of radiopharmaceuticals. A variety of methods and systems can be used to produce purified water and water for injection and all of them must fulfill the requirements for their specific use, which include TOC (total organic carbon) analysis, an indirect measurement of organic molecules present in water. The principle of TOC method is the oxidation of organic molecules to carbon dioxide, related to the carbon concentration. The aim of this study was to evaluate the parameters of robustness in TOC method in water used in the production and quality control procedures in the Radiopharmacy Directory (DIRF), according to Resolution 899 from ANVISA (National Sanitary Agency). Purified water were obtained from Milli-RX45 system. TOC standard solutions in the range of 100-1000 ppb were prepared with potassium hydrogen phthalate anhydride, transferred to vials and sequentially analyzed by a catalytic photo-oxidation reaction with a TOC model Vwp equipment from Shimadzu Corporation (Japan). The evaluated parameters were: oxidizing volume from 0.5 to 2.5 mL, acidifying volume from 1 to 5%, integration time for TC (total carbon) and IC (inorganic carbon) curves from 2 to 10 minutes. (author)

  4. The Balanced Scorecard versus Total Quality Management: which is better for your organization?

    Science.gov (United States)

    Schwartz, Jay

    2005-10-01

    Today's health care organizations must deal with managed care, government oversight, aging baby boomers, new technologies, and increasing pharmaceutical prices. It is imperative that health care organizations adopt some form of business strategy to manage the vast amount of information available. Two of the more popular strategies among health care organizations are the Balanced Scorecard and Total Quality Management. Which one of the strategies is best for an organization? The answer to this question is that it depends on the organization. This article provides the fundamentals of each strategy and contrasts their strengths and weaknesses, so that interested organizations can make informed decisions regarding the best strategy for each organization.

  5. Factors Effecting the Total Volatile Organic Compound (TVOC Concentrations in Slovak Households

    Directory of Open Access Journals (Sweden)

    Ľudmila Mečiarová

    2017-11-01

    Full Text Available Thirty five Slovak households were selected for an investigation of indoor environmental quality. Measuring of indoor air physical and chemical factors and a questionnaire survey was performed during May 2017. The range of permissible operative temperature was not met in 11% of objects. Relative humidity met the legislative requirements in all monitored homes. Concentrations of total volatile organic compounds (TVOCs were significantly higher in the apartments than in the family houses. The average TVOC levels in the apartments and family houses were 519.7 µg/m3 and 330.2 µg/m3, respectively. Statistical analysis confirmed the effect of indoor air temperature, relative humidity and particulate matter (PM0.5 and PM1 on the levels of TVOCs. Higher TVOC levels were observed also in homes where it is not a common practice to open windows during cleaning activities. Other factors that had a statistically significant effect on concentrations of volatile organic compounds were heating type, attached garage, location of the apartment within residential building (the floor, as well as number of occupants. Higher TVOC concentrations were observed in indoor than outdoor environment, while further analysis showed the significant impact of indoor emission sources on the level of these compounds in buildings. The questionnaire study showed a discrepancy between objective measurement and subjective assessment in the household environment, and pointed to insufficient public awareness about volatile organic compounds (VOCs.

  6. Measuring the emotional climate of an organization.

    Science.gov (United States)

    Yurtsever, Gülçimen; De Rivera, Joseph

    2010-04-01

    The importance of emotional climate in the organizational climate literature has gained interest. However, few studies have concentrated on adequately measuring the emotional climate of organizations. In this study, a reliable and valid scale was developed to measure the most important aspects of emotional climate in different organizations. This study presents evidence of reliability and validity for 28 items constructed to measure emotional climate in an organization in four separate studies. The data were obtained from working people from four different organizations by self-administered questionnaires. The findings indicate that three factors--Trust, Hope, and Security--were factors of the 28-item scale. Validation data also included correlations with duration of employment. The other method of assessing criterion validity was by comparing mean scores in organizations with differing productivity; results indicated that the organization with more productive members had a significantly higher mean score on emotional climate and its subscales. The generalizability of the results to private businesses also was assessed.

  7. Screening for organic solvents in Hanford waste tanks using total non- methane organic compound vapor concentrations

    International Nuclear Information System (INIS)

    Huckaby, J.L.; Glissmeyer, J.A.; Sklarew, D.S.

    1997-02-01

    The potential ignition of organic liquids stored in the Hanford high-level radioactive waste tanks is a safety issue because expanding gases could affect tank dome integrity. This report presents results of a screening test that was applied to 75 passively ventilated waste tanks at Hanford to determine those that might contain a significant amount of organic liquid waste. The screening test is based on a simple model of tank headspace, headspace organic vapor concentrations, and certain tank physical parameters. Analyses indicate that damage to the tank dome is credible only if the organic liquid burn rate is above a threshold value, and this can occur only if the surface area of organic liquid in a tank is above a corresponding threshold value of about one square meter. Twelve tanks were identified as potentially containing at least that amount of semivolatile organic liquid based on conservative estimates. Tank head space organic vapor concentrations and physical parameters required by the screening test have been compiled and are presented for each of the tanks studied. Estimates of the ventilation rates of the waste tanks were revised to reflect recent information obtained from hydrogen monitoring data. A simple analysis of the uncertainty in the test results suggests that the largest current uncertainty in the estimation of organic liquid surface area is that associated with knowledge of the tank ventilation rate. The uncertainty analysis is applied to determine 95% confidence limits for the estimated organic waste surface area in each tank

  8. Side-by-side comparison of analytical techniques; organic acids, total organic carbon, and anions in PWR secondary cycles

    International Nuclear Information System (INIS)

    Hobart, S.A.; Byers, W.A.; Miller, M.R.; Richards, J.; Silva, H.; Palino, G.F.; Wall, P.S.

    1986-01-01

    Total Organic Carbon TOC samples should be analyzed no later than one week after they are taken and they should be stored in a refrigerated condition, if at all possible. It can be inferred that for TOC levels in the range of 50 to 120 ppb, state-of-the-art sampling and analysis techniques can produce results varying by 20 to 50 ppb. Any proposed limits for TOC should be reviewed in that light. Agreement between anion results appeared to improve over the course of the project. Both contractors agree that increased attention and care with sampling and analytical techniques probably accounted for this improvement. Utility personnel can therefore conclude that proper employee training, supervision, and motivation for proper sampling and analysis are critical if accurate anion results are to be obtained. Resonable agreement between calculated and measured values of cation conductivity suggest that both contractors had accurately determined all major anionic species

  9. Customer Loyalty Measurement at Czech Organizations

    Directory of Open Access Journals (Sweden)

    David Vykydal

    2013-07-01

    Full Text Available All organizations certified against the ISO 9001 requirements must also measure customer satisfaction. But customer loyalty represents quality management system maturity on higher level of objectivity. An purpose of the article is bring set of information on current state analysis of customer loyalty measurement at Czech companies. Principal methodology of this analysis was special field survey and our research too. Results of special research performed through focus groups, based on risk analysis in the field of quality management principles implementation, are presented there as a part of findings. The another important findings show that customer loyalty measurement is mostly underestimated or ignored at Czech organizations. Main reasons of such state are also described. As well as: the first proposal of original methodology how to measure three fundamental types of customer loyalty - advocasy, purchasing and retention loyalty is also included to this article.

  10. Objective comparison of subtotal vs. total abdominal hysterectomy regarding pelvic organ prolapse and urinary incontinence

    DEFF Research Database (Denmark)

    Andersen, Lea Laird; Møller, Lars Alling; Gimbel, Helga Margrethe Elisabeth

    2015-01-01

    OBJECTIVE: To compare subtotal and total abdominal hysterectomy regarding objective assessment of pelvic organ prolapse, urinary incontinence and voiding function 14 years after hysterectomy for benign diseases. STUDY DESIGN: Long-term follow-up of a randomized clinical trial of subtotal vs. total......, total: 100), the PFDI-20 questionnaire was answered by 140 (46.1%) (subtotal: 68, total: 72). We found no difference between subtotal and total abdominal hysterectomy in the PFDI-20 scores or regarding objectively assessed urinary incontinence or pelvic organ prolapse. In the subtotal hysterectomy group...... (443ml) (P=0.0147) according to the voiding diary. CONCLUSION: Subtotal and total abdominal hysterectomy are comparable regarding long-term objective pelvic organ prolapse and urinary incontinence. The subtotal hysterectomy group had a higher Qmax and voided volume....

  11. Development of Performance Measures for the Implementation of Total Quality Management in Indian Industry

    OpenAIRE

    Perminderjit Singh; Sukhvir Singh

    2015-01-01

    Total Quality Management (TQM) refers to management methods used to enhance quality and productivity in business organizations. Total Quality Management (TQM) has become a frequently used term in discussions concerning quality. Total Quality management has brought rise in demands on the organizations policy and the customers have gained more importance in the organizations focus. TQM is considered as an important management tool, which helps the organizations to satisfy their customers. In pr...

  12. Assessing Educational Processes Using Total-Quality-Management Measurement Tools.

    Science.gov (United States)

    Macchia, Peter, Jr.

    1993-01-01

    Discussion of the use of Total Quality Management (TQM) assessment tools in educational settings highlights and gives examples of fishbone diagrams, or cause and effect charts; Pareto diagrams; control charts; histograms and check sheets; scatter diagrams; and flowcharts. Variation and quality are discussed in terms of continuous process…

  13. Total error vs. measurement uncertainty: revolution or evolution?

    Science.gov (United States)

    Oosterhuis, Wytze P; Theodorsson, Elvar

    2016-02-01

    The first strategic EFLM conference "Defining analytical performance goals, 15 years after the Stockholm Conference" was held in the autumn of 2014 in Milan. It maintained the Stockholm 1999 hierarchy of performance goals but rearranged them and established five task and finish groups to work on topics related to analytical performance goals including one on the "total error" theory. Jim Westgard recently wrote a comprehensive overview of performance goals and of the total error theory critical of the results and intentions of the Milan 2014 conference. The "total error" theory originated by Jim Westgard and co-workers has a dominating influence on the theory and practice of clinical chemistry but is not accepted in other fields of metrology. The generally accepted uncertainty theory, however, suffers from complex mathematics and conceived impracticability in clinical chemistry. The pros and cons of the total error theory need to be debated, making way for methods that can incorporate all relevant causes of uncertainty when making medical diagnoses and monitoring treatment effects. This development should preferably proceed not as a revolution but as an evolution.

  14. Distribution of Total Volatile Organic Compounds at taxi drivers in Tehran

    Directory of Open Access Journals (Sweden)

    Seyyed Mohammad Javad Golhosseini

    2015-06-01

    Full Text Available Air pollution is currently the most serious environmental health threat worldwide. Volatile Organic Compounds (VOC are considered as the main effective factors in causing air pollution. Vehicles are among the major sources which emit these compounds, so it seems that automobiles’ microenvironment is one of the places where people are exposed to high concentration of VOC. Evaluating the exposure amount of Total Volatile Organic Compounds (TVOC can indeed be used as an indicator to estimate the amount of exposure to every individual VOC. This study was conducted on the concentration of TVOC inside Tehran taxies for a period of one year. For this purpose, a real time instrument equipped with photo-ionization detector (PID was used. Consequently, the highest and the lowest measured TVOC in taxies equaled 3.33 ppm and 0.72 ppm, respectively. In addition, the arithmetic mean of TVOC concentration was 1.77±0.53 ppm inside the examined taxies. In this study, the parameters like measurement time, climate and vehicle conditions were found to have significant effect on the amount of exposure to TVOC.

  15. A comparison of new measurements of total monoterpene flux with improved measurements of speciated monoterpene flux

    Directory of Open Access Journals (Sweden)

    A. Lee

    2005-01-01

    Full Text Available Many monoterpenes have been identified in forest emissions using gas chromatography (GC. Until now, it has been impossible to determine whether all monoterpenes are appropriately measured using GC techniques. We used a proton transfer reaction mass spectrometer (PTR-MS coupled with the eddy covariance (EC technique to measure mixing ratios and fluxes of total monoterpenes above a ponderosa pine plantation. We compared PTR-MS-EC results with simultaneous measurements of eight speciated monoterpenes, β-pinene, α-pinene, 3-carene, d-limonene, β-phellandrene, α-terpinene, camphene, and terpinolene, made with an automated, in situ gas chromatograph with flame ionization detectors (GC-FID, coupled to a relaxed eddy accumulation system (REA. Monoterpene mixing ratios and fluxes measured by PTR-MS averaged 30±2.3% and 31±9.2% larger than by GC-FID, with larger mixing ratio discrepancies between the two techniques at night than during the day. Two unidentified peaks that correlated with β-pinene were resolved in the chromatograms and completely accounted for the daytime difference and reduced the nighttime mixing ratio difference to 20±2.9%. Measurements of total monoterpenes by PTR-MS-EC indicated that GC-FID-REA measured the common, longer-lived monoterpenes well, but that additional terpenes were emitted from the ecosystem that represented an important contribution to the total mixing ratio above the forest at night.

  16. Measurement of the neutron total cross section of sodium

    International Nuclear Information System (INIS)

    Larson, D.C.; Harvey, J.A.; Hill, M.W.

    1976-01-01

    The transmission of neutrons through a sample of pure sodium was measured in the energy range 40 keV to 20 MeV. The measurement points out several areas for improvement in the sodium evaluation for ENDF/B-V, the most important being the broadening of the minimum at 300 keV

  17. Nitrate radical oxidation of γ-terpinene: hydroxy nitrate, total organic nitrate, and secondary organic aerosol yields

    Science.gov (United States)

    Slade, Jonathan H.; de Perre, Chloé; Lee, Linda; Shepson, Paul B.

    2017-07-01

    Polyolefinic monoterpenes represent a potentially important but understudied source of organic nitrates (ONs) and secondary organic aerosol (SOA) following oxidation due to their high reactivity and propensity for multi-stage chemistry. Recent modeling work suggests that the oxidation of polyolefinic γ-terpinene can be the dominant source of nighttime ON in a mixed forest environment. However, the ON yields, aerosol partitioning behavior, and SOA yields from γ-terpinene oxidation by the nitrate radical (NO3), an important nighttime oxidant, have not been determined experimentally. In this work, we present a comprehensive experimental investigation of the total (gas + particle) ON, hydroxy nitrate, and SOA yields following γ-terpinene oxidation by NO3. Under dry conditions, the hydroxy nitrate yield = 4(+1/-3) %, total ON yield = 14(+3/-2) %, and SOA yield ≤ 10 % under atmospherically relevant particle mass loadings, similar to those for α-pinene + NO3. Using a chemical box model, we show that the measured concentrations of NO2 and γ-terpinene hydroxy nitrates can be reliably simulated from α-pinene + NO3 chemistry. This suggests that NO3 addition to either of the two internal double bonds of γ-terpinene primarily decomposes forming a relatively volatile keto-aldehyde, reconciling the small SOA yield observed here and for other internal olefinic terpenes. Based on aerosol partitioning analysis and identification of speciated particle-phase ON applying high-resolution liquid chromatography-mass spectrometry, we estimate that a significant fraction of the particle-phase ON has the hydroxy nitrate moiety. This work greatly contributes to our understanding of ON and SOA formation from polyolefin monoterpene oxidation, which could be important in the northern continental US and the Midwest, where polyolefinic monoterpene emissions are greatest.

  18. Why is organization theory so ignorant: The neglect of total institutions?

    NARCIS (Netherlands)

    Clegg, S.R.

    2006-01-01

    Organization theory has, on the whole, failed to adequately address the role that organizations have played in some of the crimes of humanity. The tools to do so have long been available to the discipline, in work by scholars such as Goffman on total institutions, Foucault on disciplinary

  19. Integrated Data Fusion and Mining Techniques for Monitoring Total Organic Carbon Concentrations in a Lake

    Science.gov (United States)

    Total organic carbon (TOC) in surface waters, markedly of seasonal variations, is a known precursor of disinfection byproducts such as Total Trihalomethanes (TTHM) in drinking water treatment. Real-time knowledge of TOC distribution in source water can help treatment operation to...

  20. Measurement of total dissolved solids using electrical conductivity

    International Nuclear Information System (INIS)

    Ray, Vinod K.; Jat, J.R.; Reddy, G.B.; Balaji Rao, Y.; Phani Babu, C.; Kalyanakrishnan, G.

    2017-01-01

    Total dissolved solids (TDS) is an important parameter for the disposal of effluents generated during processing of different raw materials like Magnesium Di-uranate (MDU), Heat Treated Uranium Peroxide (HTUP), Sodium Di-uranate (SDU) in Uranium Extraction plant and Washed and Dried Frit (WDF) in Zirconium Extraction Plant. The present paper describes the use of electrical conductivity for determination of TDS. As electrical conductivity is matrix dependent property, matrix matched standards were prepared for determination of TDS in ammonium nitrate solution (AN) and mixture of ammonium nitrate and ammonium sulphate (AN/AS) and results were found to be in good agreement when compared with evaporation method. (author)

  1. Measurement of human potential in organizations

    Directory of Open Access Journals (Sweden)

    Rosa María Fuchs Ángeles

    2015-09-01

    Full Text Available Companies around the world are concerned about talent management in their organizations. The concern is to retain talented employees and this may not be possible if they are not properly identified. Performance and potential evaluations become then important. Performance evaluations qualify the historical record of the employee, so their measurement is provided. However, measuring the potential performance assesses potential future charges, therefore it is not a simple task. In this paper, characteristics evaluated in potential employees and tools that are commonly used are presented. Also, the case of four companies operating in Peru is shown.

  2. Measuring thin films using quantitative frustrated total internal reflection (FTIR)

    NARCIS (Netherlands)

    Shirota, Minori; van Limbeek, Michiel A.J.; Lohse, Detlef; Sun, Chao

    2017-01-01

    Abstract.: In the study of interactions between liquids and solids, an accurate measurement of the film thickness between the two media is essential to study the dynamics. As interferometry is restricted by the wavelength of the light source used, recent studies of thinner films have prompted the

  3. Measuring total economic benefits from water in plantation forestry ...

    African Journals Online (AJOL)

    A quasi input-output framework was applied to measuring direct and indirect economic benefits from water use in plantation forestry in the Crocodile river catchment of South Africa. The study accounted for indirect economic benefits generated in downstream timber processing activities and input supply sectors linked with ...

  4. Measuring total health inequality: adding individual variation to group-level differences

    Directory of Open Access Journals (Sweden)

    Gakidou Emmanuela

    2002-08-01

    Full Text Available Abstract Background Studies have revealed large variations in average health status across social, economic, and other groups. No study exists on the distribution of the risk of ill-health across individuals, either within groups or across all people in a society, and as such a crucial piece of total health inequality has been overlooked. Some of the reason for this neglect has been that the risk of death, which forms the basis for most measures, is impossible to observe directly and difficult to estimate. Methods We develop a measure of total health inequality – encompassing all inequalities among people in a society, including variation between and within groups – by adapting a beta-binomial regression model. We apply it to children under age two in 50 low- and middle-income countries. Our method has been adopted by the World Health Organization and is being implemented in surveys around the world; preliminary estimates have appeared in the World Health Report (2000. Results Countries with similar average child mortality differ considerably in total health inequality. Liberia and Mozambique have the largest inequalities in child survival, while Colombia, the Philippines and Kazakhstan have the lowest levels among the countries measured. Conclusions Total health inequality estimates should be routinely reported alongside average levels of health in populations and groups, as they reveal important policy-related information not otherwise knowable. This approach enables meaningful comparisons of inequality across countries and future analyses of the determinants of inequality.

  5. A Total Management Measurement Model for the Naval Weapons Center

    Science.gov (United States)

    1991-02-01

    Efficiency Productivity Public safety Employee safety Safety’Sccurity Customer safety Product security _ Quality of worklife Corporate Concern for...3 Corporate-ievel measures should represent a balance of in-house expertise; types of customers; and issues that surpass the customers’ I expertise...consideration. Examining the balance of distribution of these resources is also important. Addressing these issues would link the best potential to the most

  6. Whole-body dose meters. Measurements of total activity

    International Nuclear Information System (INIS)

    Koeppe, P.; Klinikum Steglitz, Berlin

    1990-01-01

    By means of measurements using a whole-body dose meter, the course of the incorporation of radionuclides was established between April 1986 and May 1989 for unchanged conditions of alimentation, activity-conscious alimentation, and uniquely increased incorporation. Monitoring covered persons from the most different spheres of life. The incorporation is compared with the one resulting from nuclear weapons explosions in the atmosphere. (DG) [de

  7. Enhanced coagulation for turbidity and Total Organic Carbon (TOC) removal from river Kansawati water.

    Science.gov (United States)

    Narayan, Sumit; Goel, Sudha

    2011-01-01

    The objective of this study was to determine optimum coagulant doses for turbidity and Total Organic Carbon (TOC) removal and evaluate the extent to which TOC can be removed by enhanced coagulation. Jar tests were conducted in the laboratory to determine optimum doses of alum for the removal of turbidity and Natural Organic Matter (NOM) from river water. Various other water quality parameters were measured before and after thejar tests and included: UV Absorbance (UVA) at 254 nm, microbial concentrations, TDS, conductivity, hardness, alkalinity, and pH. The optimum alum dose for removal of turbidity and TOC was 20 mg/L for the sample collected in November 2009 and 100 mg/L for the sample collected in March 2010. In both cases, the dose for enhanced coagulation was significantly higher than that for conventional coagulation. The gain in TOC removal was insignificant compared to the increase in coagulant dose required. This is usual for low TOC (TOC need to be tested to demonstrate the effectiveness of enhanced coagulation.

  8. Total organic carbon, an important tool in an holistic approach to hydrocarbon source fingerprinting

    Energy Technology Data Exchange (ETDEWEB)

    Boehm, P.D.; Burns, W.A.; Page, D.S.; Bence, A.E.; Mankiewicz, P.J.; Brown, J.S.; Douglas, G.S. [Battelle Member Inst., Waltham, MA (United States)

    2002-07-01

    The identification and allocation of multiple hydrocarbon sources in marine sediments is best achieved using an holistic approach. Total organic carbon (TOC) is one important tool that can constrain the contributions of specific sources and rule out incorrect source allocations in cases where inputs are dominated by fossil organic carbon. In a study of the benthic sediments from Prince William Sound (PWS) and the Gulf of Alaska (GOA), we find excellent agreement between measured TOC and TOC calculated from hydrocarbon fingerprint matches of polycyclic aromatic hydrocarbons (PAH) and chemical biomarkers. Confirmation by two such independent source indicators (TOC and fingerprint matches) provides evidence that source allocations determined by the fingerprint matches are robust and that the major TOC sources have been correctly identified. Fingerprint matches quantify the hydrocarbon contributions of various sources to the benthic sediments and the degree of hydrocarbon winnowing by waves and currents. TOC contents are then calculated using source allocation results from fingerprint matches and the TOCs of contributing sources. Comparisons of the actual sediment TOC values and those calculated from source allocation support our earlier published findings that the natural petrogenic hydrocarbon background in sediments in this area comes from eroding Tertiary shales and associated oil seeps along the northern GOA coast and exclude thermally mature area coals from being important contributors to the PWS background due to their high TOC content.

  9. Temporal and spatial distributions of sediment total organic carbon in an estuary river.

    Science.gov (United States)

    Ouyang, Y; Zhang, J E; Ou, L-T

    2006-01-01

    Understanding temporal and spatial distributions of naturally occurring total organic carbon (TOC) in sediments is critical because TOC is an important feature of surface water quality. This study investigated temporal and spatial distributions of sediment TOC and its relationships to sediment contaminants in the Cedar and Ortega Rivers, Florida, USA, using three-dimensional kriging analysis and field measurement. Analysis of field data showed that large temporal changes in sediment TOC concentrations occurred in the rivers, which reflected changes in the characteristics and magnitude of inputs into the rivers during approximately the last 100 yr. The average concentration of TOC in sediments from the Cedar and Ortega Rivers was 12.7% with a maximum of 22.6% and a minimum of 2.3%. In general, more TOC accumulated at the upper 1.0 m of the sediment in the southern part of the Ortega River although the TOC sedimentation varied with locations and depths. In contrast, high concentrations of sediment contaminants, that is, total polycyclic aromatic hydrocarbons (PAHs) and polychlorinated biphenyls (PCBs), were found in sediments from the Cedar River. There was no correlation between TOC and PAHs or PCBs in these river sediments. This finding is in contradiction to some other studies which reported that the sorption of hydrocarbons is highly related to the organic matter content of sediments. This discrepancy occurred because of the differences in TOC and hydrocarbon source input locations. It was found that more TOC loaded into the southern part of the Ortega River, while almost all of the hydrocarbons entered into the Cedar River. This study suggested that the locations of their input sources as well as the land use patterns should also be considered when relating hydrocarbons to sediment TOC.

  10. Calculating germination measurements and organizing spreadsheets

    OpenAIRE

    Ranal, Marli A.; Santana, Denise Garcia de; Ferreira, Wanessa Resende; Mendes-Rodrigues, Clesnan

    2009-01-01

    With the objective to minimize difficulties for beginners we are proposing the use of a conventional spreadsheet for the calculations of the main germination (or emergence) measurements, the organization of the final data for the statistical analysis and some electronic commands involved in these steps. Com o objetivo de minimizar as dificuldades dos iniciantes, estamos propondo o uso de planilhas eletrônicas convencionais para o cálculo das principais medidas de germinação (ou emergência)...

  11. Total organic carbon, an important tool in a holistic approach to hydrocarbon source fingerprinting

    International Nuclear Information System (INIS)

    Boehm, P.D.; Burns, W.A.; Page, D.S.; Bence, A.E.; Mankiewicz, P.J.; Brown, J.S.; Douglas, G.S.

    2002-01-01

    Total organic carbon (TOC) was used to verify the consistency of source allocation results for the natural petrogenic hydrocarbon background of the northern Gulf of Alaska and Prince William Sound where the Exxon Valdez oil spill occurred in 1998. The samples used in the study were either pre-spill sediments or from the seafloor outside the spill path. It is assumed that the natural petrogenic hydrocarbon background in the area comes from either seep oil residues and shale erosion including erosion from petroleum source rock shales, or from coals including those of the Bering River coalfields. The objective of this study was to use the TOC calculations to discriminate between the two very different sources. TOC can constrain the contributions of specific sources and rule out incorrect source allocations, particularly when inputs are dominated by fossil organic carbon. The benthic sediments used in this study showed excellent agreement between measured TOC and calculated TOC from hydrocarbon fingerprint matches of polycyclic aromatic hydrocarbons (PAH) and chemical biomarkers. TOC and fingerprint matches confirmed that TOC sources were properly identified. The matches quantify the hydrocarbon contributions of different sources to the benthic sediments and the degree of hydrocarbon winnowing by waves and currents. It was concluded that the natural petrogenic hydrocarbon background in the sediments in the area comes from eroding Tertiary shales and oil seeps along the northern Gulf of Alaska coast. Thermally mature area coals are excluded from being important contributors to the background at Prince William Sound because of their high TOC content. 26 refs., 4 figs

  12. Total organic carbon, an important tool in a holistic approach to hydrocarbon source fingerprinting

    Energy Technology Data Exchange (ETDEWEB)

    Boehm, P.D. [Battelle, Waltham, MA (United States); Burns, W.A. [W.A. Burns Consulting Services, Houston, TX (United States); Page, D.S. [Bowdoin College, Brunswick, ME (United States); Bence, A.E.; Mankiewicz, P.J. [ExxonMobil Upstream Research Co., Houston, TX (United States); Brown, J.S.; Douglas, G.S. [Battelle, Duxbury, MA (United States)

    2002-07-01

    Total organic carbon (TOC) was used to verify the consistency of source allocation results for the natural petrogenic hydrocarbon background of the northern Gulf of Alaska and Prince William Sound where the Exxon Valdez oil spill occurred in 1998. The samples used in the study were either pre-spill sediments or from the seafloor outside the spill path. It is assumed that the natural petrogenic hydrocarbon background in the area comes from either seep oil residues and shale erosion including erosion from petroleum source rock shales, or from coals including those of the Bering River coalfields. The objective of this study was to use the TOC calculations to discriminate between the two very different sources. TOC can constrain the contributions of specific sources and rule out incorrect source allocations, particularly when inputs are dominated by fossil organic carbon. The benthic sediments used in this study showed excellent agreement between measured TOC and calculated TOC from hydrocarbon fingerprint matches of polycyclic aromatic hydrocarbons (PAH) and chemical biomarkers. TOC and fingerprint matches confirmed that TOC sources were properly identified. The matches quantify the hydrocarbon contributions of different sources to the benthic sediments and the degree of hydrocarbon winnowing by waves and currents. It was concluded that the natural petrogenic hydrocarbon background in the sediments in the area comes from eroding Tertiary shales and oil seeps along the northern Gulf of Alaska coast. Thermally mature area coals are excluded from being important contributors to the background at Prince William Sound because of their high TOC content. 26 refs., 4 figs.

  13. Echoes of the Vision: When the Rest of the Organization Talks Total Quality.

    Science.gov (United States)

    Fairhurst, Gail T.

    1993-01-01

    Describes a case study of an organization that recently began implementing W. E. Deming's Total Quality (TQ). Finds and discusses five framing devices used in routine work conversations between leaders and members to implement the TQ vision: communicated predicaments, possible futures, jargon and vision themes, positive spin, and agenda setting.…

  14. Total mercury, organic mercury and selenium in liver and kidney of a South American coastal dolphin

    International Nuclear Information System (INIS)

    Seixas, Tercia G.; Kehrig, Helena do A.; Costa, Monica; Fillmann, Gilberto; Di Beneditto, Ana Paula M.; Secchi, Eduardo R.; Souza, Cristina M.M.; Malm, Olaf; Moreira, Isabel

    2008-01-01

    Selenium and total and organic mercury were determined in the liver and kidney of franciscana dolphin (Pontoporia blainvillei) incidentally caught in fishing nets along two Brazilian coastal areas (southeast and south). Regional differences in the concentrations of these contaminants were observed in P. blainvillei. Liver showed the highest organic and total mercury. In general, samples of individuals collected at the southern of Brazil had the highest concentrations of selenium and total and organic mercury. No significant gender differences were observed. Growth stage influenced the accumulation of these contaminants in both organs, and hepatic concentrations increased with the body length, according to the sampling area. Molar mercury and selenium concentrations in liver were significantly correlated, with a Se:Hg ratio close to 4. The among-site differences we found may be related to differences in preferred prey, bioavailability in the marine environment, environmental conditions, or these individuals may belong to distinct populations. - This study presents some useful data on the bioaccumulation of Hg, organic Hg and Se, and their inter-element relationships in a Brazilian small cetacean

  15. Total mercury, organic mercury and selenium in liver and kidney of a South American coastal dolphin

    Energy Technology Data Exchange (ETDEWEB)

    Seixas, Tercia G. [Departamento de Quimica, PUC-Rio, 22453-900 Rio de Janeiro, RJ (Brazil); Laboratorio de Radioisotopos Eduardo Penna Franca, IBCCF-UFRJ, 21949-900 Rio de Janeiro, RJ (Brazil)], E-mail: tercia@rdc.puc-rio.br; Kehrig, Helena do A. [Laboratorio de Radioisotopos Eduardo Penna Franca, IBCCF-UFRJ, 21949-900 Rio de Janeiro, RJ (Brazil); Costa, Monica [Departamento de Oceanografia, CTG-UFPE, 50740-550 Recife, PE (Brazil); Fillmann, Gilberto [Departamento de Oceanografia, FURG, C.P. 474, 96201-900 Rio Grande, RS (Brazil); Di Beneditto, Ana Paula M. [Laboratorio de Ciencias Ambientais, CBB-UENF, 28013-602 Campos dos Goytacazes, RJ (Brazil); Secchi, Eduardo R. [Departamento de Oceanografia, FURG, C.P. 474, 96201-900 Rio Grande, RS (Brazil); Laboratorio de Tartarugas e Mamiferos Marinhos, Departamento de Oceanografia e Museu Oceanografico ' Prof. E.C. Rios' , FURG, 96201-900 Rio Grande, RS (Brazil); Souza, Cristina M.M. [Laboratorio de Ciencias Ambientais, CBB-UENF, 28013-602 Campos dos Goytacazes, RJ (Brazil); Malm, Olaf [Laboratorio de Radioisotopos Eduardo Penna Franca, IBCCF-UFRJ, 21949-900 Rio de Janeiro, RJ (Brazil); Moreira, Isabel [Departamento de Quimica, PUC-Rio, 22453-900 Rio de Janeiro, RJ (Brazil)

    2008-07-15

    Selenium and total and organic mercury were determined in the liver and kidney of franciscana dolphin (Pontoporia blainvillei) incidentally caught in fishing nets along two Brazilian coastal areas (southeast and south). Regional differences in the concentrations of these contaminants were observed in P. blainvillei. Liver showed the highest organic and total mercury. In general, samples of individuals collected at the southern of Brazil had the highest concentrations of selenium and total and organic mercury. No significant gender differences were observed. Growth stage influenced the accumulation of these contaminants in both organs, and hepatic concentrations increased with the body length, according to the sampling area. Molar mercury and selenium concentrations in liver were significantly correlated, with a Se:Hg ratio close to 4. The among-site differences we found may be related to differences in preferred prey, bioavailability in the marine environment, environmental conditions, or these individuals may belong to distinct populations. - This study presents some useful data on the bioaccumulation of Hg, organic Hg and Se, and their inter-element relationships in a Brazilian small cetacean.

  16. Association of nitrate, nitrite, and total organic carbon (TOC) in drinking water and gastrointestinal disease.

    Science.gov (United States)

    Khademikia, Samaneh; Rafiee, Zahra; Amin, Mohammad Mehdi; Poursafa, Parinaz; Mansourian, Marjan; Modaberi, Amir

    2013-01-01

    We aimed to investigate the amounts of nitrate, nitrite, and total organic carbon (TOC) in two drinking water sources and their relationship with some gastrointestinal diseases. This cross-sectional study was conducted in 2012 in Iran. Two wells located in residential areas were selected for sampling and measuring the TOC, nitrate (NO3(-)), and nitrite (NO2(-)). This water is used for drinking as well as for industrial and agricultural consumption. Nitrate and nitrite concentrations of water samples were analyzed using DR 5000 spectrophotometer. The information of patients was collected from the records of the main referral hospital of the region for gastrointestinal diseases. In both areas under study, the mean water nitrate and nitrite concentrations were higher in July than in other months. The mean TOC concentrations in areas 1 and 2 were 2.29 ± 0.012 and 2.03 ± 0.309, respectively. Pollutant concentration and gastrointestinal disease did not show any significant relationship (P > 0.05). Although we did not document significant association of nitrite, nitrate, and TOC content of water with gastrointestinal diseases, it should be considered that such health hazards may develop over time, and the quality of water content should be controlled to prevent different diseases.

  17. C-14 measurements in organic sediments

    International Nuclear Information System (INIS)

    Vagner, Irina; Varlam, Carmen; Stefanescu, Ioan; Faurescu, Ionut; Bogdan, Diana; Faurescu, Denisa; Cuna, Stela

    2009-01-01

    Full text: The CO 2 direct absorption method of preparing samples for radiocarbon analysis by liquid scintillation counting has been successfully applied in many laboratories primarily for 'dating' the groundwater. Even if the method follows the similar principle as by the benzene synthesis method, time less consuming by the direct absorption method is a strong motivation enhancing the type of samples that can be prepared by this method. The samples used to settle the procedure were various types of soil and slurry from the bottom sediments in rivers and lakes. The carbon occurring in those samples can be inorganic or organic carbon. Inorganic carbon can be analyzed by direct absorption method rather easy by sample acidification and CO 2 capture. In this work it has been investigated a hybrid method that connects the wet oxidation of organic carbon with direct absorption method. The wet oxidation with potassium dichromate 1N solution, in presence of concentrated sulphuric acid and silver sulphate was applied to samples, prior acidification to release inorganic carbon as CO 2 . To overcome the concern of incomplete digestion of organic matter, the procedure was conducted by extensive heating of the sample during wet oxidation process. Possibilities of occurrence of isotopic fractionation during CO 2 production from raw material were investigated by measuring δ 13 C from sample and the CO 2 obtained. Special attention was paid to sample preparation technique and the 'direct absorption method' has been used with few 'home-made' improvements in order to increase the reproducibility and accuracy of this simple and less-time consuming method. (authors)

  18. Quality Control of Gamma Irradiated Dwarf Mallow (Malva neglecta Wallr.) Based on Color, Organic Acids, Total Phenolics and Antioxidant Parameters.

    Science.gov (United States)

    Pinela, José; Barros, Lillian; Antonio, Amilcar L; Carvalho, Ana Maria; Oliveira, M Beatriz P P; Ferreira, Isabel C F R

    2016-04-08

    This study addresses the effects of gamma irradiation (1, 5 and 8 kGy) on color, organic acids, total phenolics, total flavonoids, and antioxidant activity of dwarf mallow (Malva neglecta Wallr.). Organic acids were analyzed by ultra fast liquid chromatography (UFLC) coupled to a photodiode array (PDA) detector. Total phenolics and flavonoids were measured by the Folin-Ciocalteu and aluminium chloride colorimetric methods, respectively. The antioxidant activity was evaluated based on the DPPH(•) scavenging activity, reducing power, β-carotene bleaching inhibition and thiobarbituric acid reactive substances (TBARS) formation inhibition. Analyses were performed in the non-irradiated and irradiated plant material, as well as in decoctions obtained from the same samples. The total amounts of organic acids and phenolics recorded in decocted extracts were always higher than those found in the plant material or hydromethanolic extracts, respectively. The DPPH(•) scavenging activity and reducing power were also higher in decocted extracts. The assayed irradiation doses affected differently the organic acids profile. The levels of total phenolics and flavonoids were lower in the hydromethanolic extracts prepared from samples irradiated at 1 kGy (dose that induced color changes) and in decocted extracts prepared from those irradiated at 8 kGy. The last samples also showed a lower antioxidant activity. In turn, irradiation at 5 kGy favored the amounts of total phenolics and flavonoids. Overall, this study contributes to the understanding of the effects of irradiation in indicators of dwarf mallow quality, and highlighted the decoctions for its antioxidant properties.

  19. Lean Principles’Potential Measurement Framework for Service Organization

    Directory of Open Access Journals (Sweden)

    M. D. Vadhvani

    2016-06-01

    Full Text Available Role of service sector can be considered vital as these industries are accountable for accelerating the major functions of the secondary organizations. Hence it is a very important element of economy in enhancing competitive dimensions- quality, flexibility, cost and delivery. Improvement initiatives such as Total Quality Management, Lean Practices, and Leansigma focus on increasing the competitive dimensions. Among these Lean Practices are having the inherent principles of reducing the cost and increasing the quality by focusing the non value added activities from the value chain of the service or product. Lean Principles (LPs are being practiced since long by the organizations of secondary sectors and followed by that of the tertiary sectors. Albeit the reported improvement achieved are limited by the drawbacks such as lack of proper set of guidelines, partial features of measurable characteristics, lack of guideline for measurement. Present work proposes a measurement frame work with aids of flowchart and questionnaire for measuring the potential of LPs in service organization which help them to take accompanying initiatives to implement the LPs.

  20. Method for obtaining more precise measures of excreted organic carbon

    International Nuclear Information System (INIS)

    Anon.

    1977-01-01

    A new method for concentrating and measuring excreted organic carbon by lyophilization and scintillation counting is efficient, improves measurable radioactivity, and increases precision for estimates of organic carbon excreted by phytoplankton and macrophytes

  1. Symptoms of mothers and infants related to total volatile organic compounds in household products

    OpenAIRE

    Farrow, A; Taylor, H; Northstone, K; Golding, J

    2003-01-01

    The authors sought to determine whether reported symptoms of mothers and infants were associated significantly with the use of household products that raised indoor levels of total volatile organic compounds (TVOCs). Data collected from 170 homes within the Avon Longitudinal Study of Parents and Children (ALSPAC: a large birth cohort of more than 10,000) had determined which household products were associated with the highest levels of TVOCs. The latter data were collected over a period that ...

  2. The organic contamination level based on the total soil mass is not a proper index of the soil contamination intensity

    Science.gov (United States)

    Hung, H.-W.; Daniel, Sheng G.; Lin, T.-F.; Su, Y.; Chiou, C.T.

    2009-01-01

    Concentrations of organic contaminants in common productive soils based on the total soil mass give a misleading account of actual contamination effects. This is attributed to the fact that productive soils are essentially water-saturated, with the result that the soil uptake of organic compounds occurs principally by partition into the soil organic matter (SOM). This report illustrates that the soil contamination intensity of a compound is governed by the concentration in the SOM (Com) rather than by the concentration in whole soil (Cs). Supporting data consist of the measured levels and toxicities of many pesticides in soils of widely differing SOM contents and the related levels in in-situ crops that defy explanation by the Cs values. This SOM-based index is timely needed for evaluating the contamination effects of food crops grown in different soils and for establishing a dependable priority ranking for intended remediation of numerous contamination sites.

  3. Chemical attributes, total organic carbon stock and humified fractions of organic matter soil submitted to different systems of sugarcane management

    Directory of Open Access Journals (Sweden)

    Jean Sérgio Rosset

    2014-10-01

    Full Text Available Mechanized harvesting maintenance of trash from cane sugar and soil application of waste as vinasse and filter cake can improve the system of crop yield. Thus, this study aimed to evaluate the changes in the chemical, the stock of total organic carbon and humified organic matter fractions in an Oxisol cultivated with cane sugar with the following management systems: with sugarcane vinasse application (CCV, without application of burnt cane waste (CQS, with burnt cane vinasse application (CQV, with application of burnt cane filter cake (CQTF and burnt cane with joint application of vinasse and filter cake (CQVTF. For reference we used an area of natural vegetation (NV, Cerrado sensu stricto. Treatment CQVTF showed improvement in soil chemical properties, increased inventory levels of total organic carbon – TOC (values ranging from 21.28 to 40.02 Mg ha-1 and humified fractions of soil organic matter in relation to other treatments. The CQS area at a depth of 0-0.05 m, showed the greatest losses of soil TOC stocks (56.3% compared to NV. The adoption of management presented CCV and chemical attributes of the soil TOC stocks equivalent to those observed in areas with CQV CQTF and despite the short period of adoption (3 years. The TOC correlated with the sum of bases (r = 0.76 **, cation exchange capacity (r = 0.59 ** and base saturation (r = 0.63 **, while the humic acids (r = 0.40 ** fulvic acids (r = 0.49 ** and humin (r = 0.59 ** correlated with the cation exchange capacity of the soil. These results indicate that the preservation of trash in the management of cane sugar added to the application of vinasse and filter cake increases the TOC stocks promoting improvement in soil chemical properties.

  4. Higher Antioxidant Activity, Total Flavonols, and Specific Quercetin Glucosides in Two Different Onion (Allium cepa L.) Varieties Grown under Organic Production: Results from a 6-Year Field Study.

    Science.gov (United States)

    Ren, Feiyue; Reilly, Kim; Kerry, Joseph P; Gaffney, Michael; Hossain, Mohammad; Rai, Dilip K

    2017-06-28

    We carried out a 6-year study to assess the effect of conventional, organic, and mixed cultivation practices on bioactive compounds (flavonoids, anthocyanins) and antioxidant capacity in onion. Total flavonoids, total anthocyanins, individual flavonols, individual anthocyanins, and antioxidant activity were measured in two varieties ('Hyskin' and 'Red Baron') grown in a long-term split-plot factorial systems comparison trial. This is the first report of repeated measurements of bioactive content over an extensive time period in a single crop type within the same trial. Antioxidant activity (DPPH and FRAP), total flavonol content, and levels of Q 3,4' D and Q 3 G were higher in both varieties under fully organic compared to fully conventional management. Total flavonoids were higher in 'Red Baron' and when onions were grown under organic soil treatment. Differences were primarily due to different soil management practices used in organic agriculture rather than pesticide/ herbicide application.

  5. Measurement of the total cross section with ALFA Detector at ATLAS

    CERN Document Server

    Trzebinski, M; The ATLAS collaboration

    2017-01-01

    The main goals of the Absolute Luminosity For ATLAS (ALFA) detector is to provide an absolute luminosity and total cross section measurement. The measurement method used, the detector alignment and the quality of the collected data are discussed.

  6. Towards a Total Cross Section Measurement with the ALFA Detector at ATLAS

    CERN Document Server

    Trzebiński, Maciej

    2013-01-01

    The main goals of the Absolute Luminosity For ATLAS (ALFA) detector is to provide an absolute luminosity and total cross section measurement. The measurement method used, the detector alignment and the quality of the collected data are discussed.

  7. Sky brightness and color measurements during the 21 August 2017 total solar eclipse.

    Science.gov (United States)

    Bruns, Donald G; Bruns, Ronald D

    2018-06-01

    The sky brightness was measured during the partial phases and during totality of the 21 August 2017 total solar eclipse. A tracking CCD camera with color filters and a wide-angle lens allowed measurements across a wide field of view, recording images every 10 s. The partially and totally eclipsed Sun was kept behind an occulting disk attached to the camera, allowing direct brightness measurements from 1.5° to 38° from the Sun. During the partial phases, the sky brightness as a function of time closely followed the integrated intensity of the unobscured fraction of the solar disk. A redder sky was measured close to the Sun just before totality, caused by the redder color of the exposed solar limb. During totality, a bluer sky was measured, dimmer than the normal sky by a factor of 10,000. Suggestions for enhanced measurements at future eclipses are offered.

  8. Sensible organizations: technology and methodology for automatically measuring organizational behavior.

    Science.gov (United States)

    Olguin Olguin, Daniel; Waber, Benjamin N; Kim, Taemie; Mohan, Akshay; Ara, Koji; Pentland, Alex

    2009-02-01

    We present the design, implementation, and deployment of a wearable computing platform for measuring and analyzing human behavior in organizational settings. We propose the use of wearable electronic badges capable of automatically measuring the amount of face-to-face interaction, conversational time, physical proximity to other people, and physical activity levels in order to capture individual and collective patterns of behavior. Our goal is to be able to understand how patterns of behavior shape individuals and organizations. By using on-body sensors in large groups of people for extended periods of time in naturalistic settings, we have been able to identify, measure, and quantify social interactions, group behavior, and organizational dynamics. We deployed this wearable computing platform in a group of 22 employees working in a real organization over a period of one month. Using these automatic measurements, we were able to predict employees' self-assessments of job satisfaction and their own perceptions of group interaction quality by combining data collected with our platform and e-mail communication data. In particular, the total amount of communication was predictive of both of these assessments, and betweenness in the social network exhibited a high negative correlation with group interaction satisfaction. We also found that physical proximity and e-mail exchange had a negative correlation of r = -0.55 (p 0.01), which has far-reaching implications for past and future research on social networks.

  9. Leaching behavior of total organic carbon, nitrogen, and phosphorus from banana peel.

    Science.gov (United States)

    Jiang, Ruixue; Sun, Shujuan; Xu, Yan; Qiu, Xiudong; Yang, Jili; Li, Xiaochen

    2015-01-01

    The leaching behavior of organic carbon and nutrient compounds from banana peel (BP) was investigated in batch assays with respect to particle size, contact time, pH value, and temperature. The granularity, contact time, pH, and temperature caused no significant effects on the leaching of total phosphorus (TP) from the BP. The maximum leached total nitrogen (TN) content was found at pH 5.0 and 90 minutes, while no significant effects were caused by the granularity and temperature. The maximum leached total organic carbon (TOC) content was found by using a powder of 40 mesh, 150 minutes and at pH 6.0, while the temperature had no effect on the TOC leaching. The proportions of the TN, TP, and TOC contents leached from the dried BP ranged from 33.6% to 40.9%, 60.4% to 72.7%, and 8.2% to 9.9%, respectively, indicating that BP could be a potential pollution source for surface and ground water if discharged as domestic waste or reutilized without pretreatment.

  10. Quantitation of the degree of osteoporosis by measure of total-body calcium employing neutron activation

    International Nuclear Information System (INIS)

    Cohn, S.H.; Zanzi, I.; Vaswani, A.; Wallach, S.; Aloia, J.; Ellis, K.J.

    1975-01-01

    Two techniques for measuring the amount of Ca in the total skeleton were employed: total-body neutron activation analysis (TBNAA) and the determination of the mineral content of a bone of the appendicular skeleton (absorptiometric measurement of the radius, BMC). (U.S.)

  11. Applications of Total Scattering & Pair Distribution Function Analysis in Metal-Organic Framework Materials

    DEFF Research Database (Denmark)

    Xu, Hui; Birgisson, Steinar; Sommer, Sanna

    structure. At the same time, there is an ongoing debate on whether the SBU is present prior, or during MOF crystallization in MOF chemistry. However, little is known about MOFs formation mechanism. Currently techniques to study the in situ MOF formation process mainly focused on after......-crystallization process, for example in situ XRD and SAXS/WAXS study on MOF formation. However, the pre-crystallization process in the early stage of MOF formation is still unexplored. In this project, total scattering and PDF study will be carried out to explore the MOF formation process in early stage. This includes......Metal-Organic Frameworks (MOFs) is constructed by metal-oxide nodes and organic ligands. The formation of different structures of metal-oxide nodes (also called secondary building units, SBU) is crucial for MOF final structures, because the connectivity of SBU greatly influence the final MOF...

  12. Effect of TOC [total organic carbon] on a PWR secondary cooling water system

    International Nuclear Information System (INIS)

    Gau, J.Y.; Oung, J.C.; Wang, T.Y.

    1989-01-01

    Increasing the amount of total organic carbon (TOC) during the wet layup of the steam generator was a problem in PWR nuclear power plant in Taiwan. The results of surveys of TOC in PWR secondary cooling water systems had shown that the impurity of hydrazine and the bacteria were the main reasons that increase TOC. These do not have a corrosion effect on Inconel 600 and carbon steel when the secondary cooling water containing the TOC is below 200 ppb. But the anaerobic bacteria from the steam generator in wet layup will increase corrosion rate of carbon steel and crevice corrosion of Inconel 600. (author)

  13. Maximum total organic carbon limits at different DWPF melter feed maters (U)

    International Nuclear Information System (INIS)

    Choi, A.S.

    1996-01-01

    The document presents information on the maximum total organic carbon (TOC) limits that are allowable in the DWPF melter feed without forming a potentially flammable vapor in the off-gas system were determined at feed rates varying from 0.7 to 1.5 GPM. At the maximum TOC levels predicted, the peak concentration of combustible gases in the quenched off-gas will not exceed 60 percent of the lower flammable limit during a 3X off-gas surge, provided that the indicated melter vapor space temperature and the total air supply to the melter are maintained. All the necessary calculations for this study were made using the 4-stage cold cap model and the melter off-gas dynamics model. A high-degree of conservatism was included in the calculational bases and assumptions. As a result, the proposed correlations are believed to by conservative enough to be used for the melter off-gas flammability control purposes

  14. Measurement of the total antioxidant response using a novel automated method in subjects with nonalcoholic steatohepatitis.

    Science.gov (United States)

    Horoz, Mehmet; Bolukbas, Cengiz; Bolukbas, Fusun F; Sabuncu, Tevfik; Aslan, Mehmet; Sarifakiogullari, Serpil; Gunaydin, Necla; Erel, Ozcan

    2005-11-11

    Oxidative stress, an increase in oxidants and/or a decrease in antioxidant capacity, is one of the potential biochemical mechanisms involved in the pathogenesis of nonalcoholic steatohepatitis. We aimed to investigate the total antioxidant response using a novel automated method in nonalcoholic steatohepatitis subjects. As a reciprocal measure, we also aimed to determine total peroxide level in the same plasma samples. Twenty-two subjects with biopsy proven nonalcoholic steatohepatitis and 22 healthy controls were enrolled. Total antioxidant response and total peroxide level measurements were done in all participants. The ratio percentage of total peroxide level to total antioxidant response was regarded as oxidative stress index. Total antioxidant response of subjects with nonalcoholic steatohepatitis was significantly lower than controls (p total peroxide level and mean oxidative stress index were higher (all p total peroxide level, total antioxidant response and oxidative stress index (p 0.05). Nonalcoholic steatohepatitis is associated with increased oxidant capacity, especially in the presence of liver fibrosis. The novel automated assay is a reliable and easily applicable method for total plasma antioxidant response measurement in nonalcoholic steatohepatitis.

  15. Organic indoor air pollutants: occurrence, measurement, evaluation

    National Research Council Canada - National Science Library

    Salthammer, Tunga; Uhde, Erik

    2009-01-01

    ... hand, organic chemical pollutants emitted from materials and appliances can adversely affect human health. People in developed countries spend more than 90% of their time indoors. In the light of this fact, the cleanliness of occupied spaces such as buildings, houses, and transportation systems becomes very important. In contemporary so...

  16. Measuring Student Performance in General Organic Chemistry

    Science.gov (United States)

    Austin, Ara C.; Ben-Daat, Hagit; Zhu, Mary; Atkinson, Robert; Barrows, Nathan; Gould, Ian R.

    2015-01-01

    Student performance in general organic chemistry courses is determined by a wide range of factors including cognitive ability, motivation and cultural capital. Previous work on cognitive factors has tended to focus on specific areas rather than exploring performance across all problem types and cognitive skills. In this study, we have categorized…

  17. Total organic carbon removal from a chemical lab’s wastewater using Fenton’s reagent

    Directory of Open Access Journals (Sweden)

    Oscar Mauricio Martínez Ávila

    2013-05-01

    Full Text Available Treating industrial wastewater represents a serious problem nowadays; it requires a strong understanding of the particular systems and (in most of cases ad hoc solutions. This work describes the use of Fenton’s reagent (reaction between H2O2 and Fe(II for removing total organic carbon (TOC from a particular chemical laboratory’s lab-scale batch reactor wastewater. Some operating variables (hydrogen peroxide and ferrous ion concentration, temperature and pH were evaluated regarding final TOC removal. An economic optimisation was made by means of a second order polynomial model representing these variables’ behaviour regarding TOC removal (0.94 R2. The highest experimentally reached TOC removal was 88.8% at 50 mg/L [Fe(II]0, 50 mM [H2O2]0 , pH=2.8 at 80oC, while 53.9% was obtained in optimised conditions, i.e. 36 mg/L [Fe(II]0 , 45.5 mM [H2O2]0 , pH=2.6 at 20°C. It was found that the Fenton process could achieve 41% removal, even in adverse conditions (pH close to 6. It was noted from the analysis that both H2O2 concentration and temperature had a powerful effect on organic matter degradation efficiency, as well as on total treatment cost.

  18. Measurement of the total antioxidant response using a novel automated method in subjects with nonalcoholic steatohepatitis

    Directory of Open Access Journals (Sweden)

    Sarifakiogullari Serpil

    2005-11-01

    Full Text Available Abstract Background Oxidative stress, an increase in oxidants and/or a decrease in antioxidant capacity, is one of the potential biochemical mechanisms involved in the pathogenesis of nonalcoholic steatohepatitis. We aimed to investigate the total antioxidant response using a novel automated method in nonalcoholic steatohepatitis subjects. As a reciprocal measure, we also aimed to determine total peroxide level in the same plasma samples. Methods Twenty-two subjects with biopsy proven nonalcoholic steatohepatitis and 22 healthy controls were enrolled. Total antioxidant response and total peroxide level measurements were done in all participants. The ratio percentage of total peroxide level to total antioxidant response was regarded as oxidative stress index. Results Total antioxidant response of subjects with nonalcoholic steatohepatitis was significantly lower than controls (p In subjects with nonalcoholic steatohepatitis, fibrosis score was significantly correlated with total peroxide level, total antioxidant response and oxidative stress index (p 0.05. Conclusion Nonalcoholic steatohepatitis is associated with increased oxidant capacity, especially in the presence of liver fibrosis. The novel automated assay is a reliable and easily applicable method for total plasma antioxidant response measurement in nonalcoholic steatohepatitis.

  19. Measurement of the total solar energy transmittance (g-value) for conventional glazings

    DEFF Research Database (Denmark)

    Duer, Karsten

    1998-01-01

    Three different glazings have been investigated in the Danish experimental setup METSET. (A device for calorimetric measurement of total solar energy transmittance - g-value).The purpose of the measurements is to increase the confidence in the calorimetric measurements. This is done by comparison...

  20. Tidally driven export of dissolved organic carbon, total mercury, and methylmercury from a mangrove-dominated estuary

    Science.gov (United States)

    Bergamaschi, B.A.; Krabbenhoft, D.P.; Aiken, G.R.; Patino, E.; Rumbold, D.G.; Orem, W.H.

    2012-01-01

    The flux of dissolved organic carbon (DOC) from mangrove swamps accounts for 10% of the global terrestrial flux of DOC to coastal oceans. Recent findings of high concentrations of mercury (Hg) and methylmercury (MeHg) in mangroves, in conjunction with the common co-occurrence of DOC and Hg species, have raised concerns that mercury fluxes may also be large. We used a novel approach to estimate export of DOC, Hg, and MeHg to coastal waters from a mangrove-dominated estuary in Everglades National Park (Florida, USA). Using in situ measurements of fluorescent dissolved organic matter as a proxy for DOC, filtered total Hg, and filtered MeHg, we estimated the DOC yield to be 180 (??12.6) g C m -2 yr -1, which is in the range of previously reported values. Although Hg and MeHg yields from tidal mangrove swamps have not been previously measured, our estimated yields of Hg species (28 ?? 4.5 ??g total Hg m -2 yr -1 and 3.1 ?? 0.4 ??g methyl Hg m -2 yr -1) were five times greater than is typically reported for terrestrial wetlands. These results indicate that in addition to the well documented contributions of DOC, tidally driven export from mangroves represents a significant potential source of Hg and MeHg to nearby coastal waters. ?? 2011 American Chemical Society.

  1. Effect of Sulfites on Antioxidant Activity, Total Polyphenols, and Flavonoid Measurements in White Wine.

    Science.gov (United States)

    Nardini, Mirella; Garaguso, Ivana

    2018-03-09

    Polyphenols content and antioxidant activity are directly related to the quality of wine. Wine also contains sulfites, which are added during the winemaking process. The present study aimed to evaluate the effects of sulfites on the assays commonly used to measure the antioxidant activity and polyphenols and flavonoids content of white wines. The effects of sulfites were explored both in the standard assays and in white wine. The addition of sulfites (at 1-10 μg) in the standard assays resulted in a significant, positive interference in the Folin-Ciocalteu's assay used for polyphenols measurements and in both the Ferric Reducing Antioxidant Power and 2,2'-azino-bis (3-ethylbenzothiazoline-6-sulfonic acid) diammonium salt radical cation decolorization assays, which were used for antioxidant activity evaluation. A negative interference of sulfites (at 1-20 μg) was observed for the colorimetric aluminium-chloride flavonoids assay. The addition of sulfites to organic white wines (at 25-200 mg/L wine) clearly resulted in a significant overestimation of antioxidant activity and polyphenols content, and in an underestimation of flavonoids concentration. To overcome sulfite interferences, white wines were treated with cross-linked polyvinylpyrrolidone. The total polyphenols content and antioxidant activity measurements obtained after polyvinylpyrrolidone treatment were significantly lower than those obtained in the untreated wines. Flavonoids were expected to be higher after polyvinylpyrrolidone treatment, but were instead found to be lower than for untreated wines, suggesting that in addition to sulfites, other non-phenolic reducing compounds were present in white wine and interfered with the flavonoid assay. In view of our results, we advise that a purification procedure should be applied in order to evaluate the quality of white wine.

  2. Performance measures for metropolitan planning organizations.

    Science.gov (United States)

    2012-04-01

    Performance measurement is a topic of increasing importance to transportation agencies, as issues with : funding shortfalls and concerns about transportation system efficiency lead to a shift in how transportation : decision making is carried out. In...

  3. To Measure Probable Physical Changes On The Earth During Total Solar Eclipse Using Geophysical Methods

    International Nuclear Information System (INIS)

    Gocmen, C.

    2007-01-01

    When the total solar eclipse came into question, people connected the eclipse with the earthquake dated 17.08.1999. We thought if any physical parameters change during total solar eclipse on the earth, we could measure this changing and we did the project 'To Measure Probable Physical Changes On The Earth During Total Solar Eclipse Using Geophysical Methods' We did gravity, magnetic and self-potential measurements at Konya and Ankara during total solar eclipse (29, March, 2006) and the day before eclipse and the day after eclipse. The measurements went on three days continuously twenty-four hours at Konya and daytime in Ankara. Bogazici University Kandilli Observatory gave us magnetic values in Istanbul and we compare the values with our magnetic values. Turkish State Meteorological Service sent us temperature and air pressure observations during three days, in Konya and Ankara. We interpreted all of them

  4. Total gamma activity measurements for determining the radioactivity of residual materials from nuclear power stations

    International Nuclear Information System (INIS)

    Auler, I.; Meyer, M.; Stickelmann, J.

    1995-01-01

    Large amounts of residual materials from retrofitting measures and from decommissioning of nuclear power stations shows such a weak level of radioactivity that they could be released after decision measurements. Expenses incurred with complex geometry cannot be taken with common methods. NIS developed a Release Measurement Facility (RMF) based on total gamma activity measurements especially for these kind of residual materials. The RMF has been applied for decision measurements in different nuclear power plants. Altogether about 2,000 Mg of various types of materials have been measured up to now. More than 90 % of these materials could be released 0 without any restriction after decision measurements

  5. Total antioxidants in plasma of hemodialysed patients and healthy controls measured by two commercial assays

    OpenAIRE

    Ruskovska, Tatjana; Jansen, Eugene

    2012-01-01

    Introduction: As a result of an increased interest in oxidative stress research, in both basic and clinical studies, numerous commercial test kits became available. The aim of this study was to evaluate the results for total antioxidants measured by two commercial assays in a complex clinical condition such as single hemodialysis session in patients on chronic hemodialysis treatment, in comparison to healthy controls. Methods: The level of plasma total antioxidants was measured by BAP ...

  6. Organic Electroluminescent Sensor for Pressure Measurement

    Directory of Open Access Journals (Sweden)

    Tomohide Niimi

    2012-10-01

    Full Text Available We have proposed a novel concept of a pressure sensor called electroluminescent pressure sensor (ELPS based on oxygen quenching of electroluminescence. The sensor was fabricated as an organic light-emitting device (OLED with phosphorescent dyes whose phosphorescence can be quenched by oxygenmolecules, and with a polymer electrode which permeates oxygen molecules. The sensor was a single-layer OLED with Platinum (II octaethylporphine (PtOEP doped into poly(vinylcarbazole (PVK as an oxygen sensitive emissive layer and poly(3,4-ethylenedioxythiophene mixed with poly(styrenesulfonate (PEDOT:PSS as an oxygen permeating polymer anode. The pressure sensitivity of the fabricated ELPS sample was equivalent to that of the sensor excited by an illumination light source. Moreover, the pressure sensitivity of the sensor is equivalent to that of conventional pressure-sensitive paint (PSP, which is an optical pressure sensor based on photoluminescence.

  7. Preozonation Effect on Total Organic Carbon Removal in Surface Water Treatment

    Directory of Open Access Journals (Sweden)

    Ali Torabian

    2006-06-01

    Full Text Available In drinking water treatment, preozonation is often applied in order to control the microorganisms and taste and odor causing materials, which may influence organics removal by preoxidation and adsorption. Using commercial and natural water humic substances, the positive effect of preozonation as an aid to coagulation-flocculation of these compounds was confirmed by removal of TOC removal in Tehranpars Water Treatment Plant in Tehran. These experiments were conducted as bench-scale studies through a series of jar tests using different pH coagulant dosages and total organic carbon concentration of approximately 4, 8 and 12 mg/L. In addition to TOC removal, the existence of an optimum preozonation dose (OPZD was also confirmed. Experiments show that preozonation can improve coagulation and flocculation depending on influent TOC concentration of raw water. The results demonstrate different effects of preozonation on removal of influent TOC. Preozonation showed a positive effect on a system with low influent TOC and very low molecular weight (noncolloidal humic substances.

  8. Assessment of Total Risk on Non-Target Organisms in Fungicide Application for Agricultural Sustainability

    Directory of Open Access Journals (Sweden)

    Ali Musa Bozdogan

    2014-02-01

    Full Text Available In Turkey, in 2010, the amount of pesticide (active ingredient; a.i. used in agriculture was about 23,000 metric tons, of which approximately 32% was fungicides. In 2012, 14 a.i. were used for fungus control in wheat cultivation areas in Adana province, Turkey. These a.i. were: azoxystrobin, carbendazim, difenoconazole, epoxiconazole, fluquinconazole, prochloraz, propiconazole, prothioconazole, pyraclostrobin, spiroxamine, tebuconazole, thiophanate-methyl, triadimenol, and trifloxystrobin. In this study, the potential risk of a.i. on non-target organisms in fungicide application of wheat cultivation was assessed by The Pesticide Occupational and Environmental Risk (POCER indicators. In this study, the highest human health risk was for fluquinconazole (Exceedence Factor (EF 1.798 for human health, whereas the fungicide with the highest environmental risk was propiconazole (EF 2.000 for the environment. For non-target organisms, the highest potential risk was determined for propiconazole when applied at 0.1250 kg a.i. ha-1 (EF 2.897. The lowest total risk was for azoxystrobin when applied at  0.0650 kg a.i. ha-1 (EF 0.625.

  9. Neutron total cross section measurements of gold and tantalum at the nELBE photoneutron source

    CERN Document Server

    Hannaske, Roland; Beyer, Roland; Junghans, Arnd; Bemmerer, Daniel; Birgersson, Evert; Ferrari, Anna; Grosse, Eckart; Kempe, Mathias; Kögler, Toni; Marta, Michele; Massarczyk, Ralph; Matic, Andrija; Schramm, Georg; Schwengner, Ronald; Wagner, Andreas

    2014-01-01

    Neutron total cross sections of 197 Au and nat Ta have been measured at the nELBE photoneutron source in the energy range from 0.1 - 10 MeV with a statistical uncertainty of up to 2 % and a total systematic uncertainty of 1 %. This facility is optimized for the fast neutron energy range and combines an excellent t ime structure of the neutron pulses (electron bunch width 5 ps) with a short flight path of 7 m. Because of the low instantaneous neutron flux transmission measurements of neutron total cross sections are possible, that exhibit very different beam and back ground conditions than found at other neutron sources.

  10. 1979-1999 satellite total ozone column measurements over West Africa

    Directory of Open Access Journals (Sweden)

    P. Di Carlo

    2000-06-01

    Full Text Available Total Ozone Mapping Spectrometer (TOMS instruments have been flown on NASA/GSFC satellites for over 20 years. They provide near real-time ozone data for Atmospheric Science Research. As part of preliminary efforts aimed to develop a Lidar station in Nigeria for monitoring the atmospheric ozone and aerosol levels, the monthly mean TOMS total column ozone measurements between 1979 to 1999 have been analysed. The trends of the total column ozone showed a spatial and temporal variation with signs of the Quasi Biennial Oscillation (QBO during the 20-year study period. The values of the TOMS total ozone column, over Nigeria (4-14°N is within the range of 230-280 Dobson Units, this is consistent with total ozone column data, measured since April 1993 with a Dobson Spectrophotometer at Lagos (3°21¢E, 6°33¢N, Nigeria.

  11. Watershed scale spatial variability in dissolved and total organic and inorganic carbon in contrasting UK catchments

    Science.gov (United States)

    Cumberland, S.; Baker, A.; Hudson, N. J.

    2006-12-01

    investigations into carbon fluxes in British rivers have focused on long term increases in DOC in rural and predominantly upland catchments. Our results suggest that research is needed into understanding long term variations in inorganic carbon concentration, as well as total (organic and inorganic) carbon fluxes from British rivers, to obtain total carbon loads. In particular, we provide evidence that DIC concentrations may be greater in urbanized catchments compared to equivalent non-urban catchments, with the implication that increasing urbanization in the future will see increases in riverine DIC and a decrease in the strength of any DOC DIC anti correlation. Further studies of urban catchment DIC sources, within stream processing, long term trends, and potential ecological impacts, are required.

  12. Measurement of total-body oxygen, nitrogen, and carbon in vivo by photon activation analysis

    International Nuclear Information System (INIS)

    Ulin, K.

    1984-01-01

    With the aim of assessing nutritional status, the feasibility of measuring the total body quantities of the major body elements, i.e. oxygen, nitrogen, and carbon, using the photon beam of a 45 MV betatron and a whole-body counter, has been evaluated in detail. Following photon activation a single energy γ-radiation (.511 MeV) is observed from all three elements to be measured. The half-lives of 15 O, 13 N, and 11 C, however, are sufficiently different (20.5 min, 10.0 min, and 20.4 min. respectively) to permit their measurement from an analysis of the measured decay curve. Following corrections for interfering reactions, a computer curve-fitting algorithm is used to resolve the data into 15 O, 13 N, and 11 C components. Measurements of O, N, and C have been made both in phantoms and in live and dead rats. A comparison of the body composition results from this technique with results from chemical analysis indicates that measured carbon can quite accurately predict total body fat. The comparison of the total body nitrogen measurement by photon activation with total body protein by chemical analysis was inconclusive and suggests that further work be done to verify the estimated accuracy of the nitrogen measurement

  13. Towards minimizing measurement uncertainty in total petroleum hydrocarbon determination by GC-FID

    Energy Technology Data Exchange (ETDEWEB)

    Saari, E.

    2009-07-01

    Despite tightened environmental legislation, spillages of petroleum products remain a serious problem worldwide. The environmental impacts of these spillages are always severe and reliable methods for the identification and quantitative determination of petroleum hydrocarbons in environmental samples are therefore needed. Great improvements in the definition and analysis of total petroleum hydrocarbons (TPH) were finally introduced by international organizations for standardization in 2004. This brought some coherence to the determination and, nowadays, most laboratories seem to employ ISO/DIS 16703:2004, ISO 9377-2:2000 and CEN prEN 14039:2004:E draft international standards for analysing TPH in soil. The implementation of these methods, however, usually fails because the reliability of petroleum hydrocarbon determination has proved to be poor.This thesis describes the assessment of measurement uncertainty for TPH determination in soil. Chemometric methods were used to both estimate the main uncertainty sources and identify the most significant factors affecting these uncertainty sources. The method used for the determinations was based on gas chromatography utilizing flame ionization detection (GC-FID).Chemometric methodology applied in estimating measurement uncertainty for TPH determination showed that the measurement uncertainty is in actual fact dominated by the analytical uncertainty. Within the specific concentration range studied, the analytical uncertainty accounted for as much as 68-80% of the measurement uncertainty. The robustness of the analytical method used for petroleum hydrocarbon determination was then studied in more detail. A two-level Plackett-Burman design and a D-optimal design were utilized to assess the main analytical uncertainty sources of the sample treatment and GC determination procedures. It was also found that the matrix-induced systematic error may also significantly reduce the reliability of petroleum hydrocarbon determination

  14. Total uncertainty of low velocity thermal anemometers for measurement of indoor air movements

    DEFF Research Database (Denmark)

    Jørgensen, F.; Popiolek, Z.; Melikov, Arsen Krikor

    2004-01-01

    For a specific thermal anemometer with omnidirectional velocity sensor the expanded total uncertainty in measured mean velocity Û(Vmean) and the expanded total uncertainty in measured turbulence intensity Û(Tu) due to different error sources are estimated. The values are based on a previously...... developed mathematical model of the anemometer in combination with a large database of representative room flows measured with a 3-D Laser Doppler anemometer (LDA). A direct comparison between measurements with a thermal anemometer and a 3-D LDA in flows of varying velocity and turbulence intensity shows...... good agreement not only between the two instruments but also between the thermal anemometer and its mathematical model. The differences in the measurements performed with the two instruments are all well within the measurement uncertainty of both anemometers....

  15. Radiologic total lung capacity measurement. Development and evaluation of a computer-based system

    Energy Technology Data Exchange (ETDEWEB)

    Seeley, G.W.; Mazzeo, J.; Borgstrom, M.; Hunter, T.B.; Newell, J.D.; Bjelland, J.C.

    1986-11-01

    The development of a computer-based radiologic total lung capacity (TLC) measurement system designed to be used by non-physician personnel is detailed. Four operators tested the reliability and validity of the system by measuring inspiratory PA and lateral pediatric chest radiographs with a Graf spark pen interfaced to a DEC VAX 11/780 computer. First results suggest that the ultimate goal of developing an accurate and easy to use TLC measurement system for non-physician personnel is attainable.

  16. Comparative study of radiometric and calorimetric methods for total hemispherical emissivity measurements

    Science.gov (United States)

    Monchau, Jean-Pierre; Hameury, Jacques; Ausset, Patrick; Hay, Bruno; Ibos, Laurent; Candau, Yves

    2018-05-01

    Accurate knowledge of infrared emissivity is important in applications such as surface temperature measurements by infrared thermography or thermal balance for building walls. A comparison of total hemispherical emissivity measurement was performed by two laboratories: the Laboratoire National de Métrologie et d'Essais (LNE) and the Centre d'Études et de Recherche en Thermique, Environnement et Systèmes (CERTES). Both laboratories performed emissivity measurements on four samples, chosen to cover a large range of emissivity values and angular reflectance behaviors. The samples were polished aluminum (highly specular, low emissivity), bulk PVC (slightly specular, high emissivity), sandblasted aluminum (diffuse surface, medium emissivity), and aluminum paint (slightly specular surface, medium emissivity). Results obtained using five measurement techniques were compared. LNE used a calorimetric method for direct total hemispherical emissivity measurement [1], an absolute reflectometric measurement method [2], and a relative reflectometric measurement method. CERTES used two total hemispherical directional reflectometric measurement methods [3, 4]. For indirect techniques by reflectance measurements, the total hemispherical emissivity values were calculated from directional hemispherical reflectance measurement results using spectral integration when required and directional to hemispherical extrapolation. Results were compared, taking into account measurement uncertainties; an added uncertainty was introduced to account for heterogeneity over the surfaces of the samples and between samples. All techniques gave large relative uncertainties for a low emissive and very specular material (polished aluminum), and results were quite scattered. All the indirect techniques by reflectance measurement gave results within ±0.01 for a high emissivity material. A commercial aluminum paint appears to be a good candidate for producing samples with medium level of emissivity

  17. Soil, vegetation and total organic carbon stock development in self-restoring abandoned vineyards

    Science.gov (United States)

    József Novák, Tibor; Incze, József; Spohn, Marie; Giani, Luise

    2016-04-01

    Abandoned vineyard's soil and vegetation development was studied on Tokaj Nagy-Hill, which is one of the traditional wine-producing regions of Hungary, it is declared as UNESCO World Heritage site as cultural landscape. Spatial distribution and pattern of vineyards were changing during the last several hundreds of years, therefore significant part of abandoned vineyards were subjected to long-term spontaneous secondary succession of vegetation and self-restoration of soils in absence of later cultivation. Two chronosequences of spontaneously regenerating vineyard abandonments, one on south (S-sequence) and one on southwest (SW-sequence) slope with differing times since their abandonment (193, 142, 101, 63, 39 and 14 years), were compiled and studied. The S-sequence was 25-35% sloped and strongly eroded, and the SW-sequence was 17-25% sloped and moderately eroded. The sites were investigated in respect of vegetation characteristics, soil physico-chemical characteristics, total organic carbon stocks (TOC stocks), accumulation rates of total organic carbon (TOC accumulation rates), and soil profiles, which were classified according to the World Reference Base (WRB) 2014. Vegetation development resulted in shrub-grassland mosaics, supplemented frequently by protected forb species and forest development at the earliest abandonment in S-sequence, and predominantly to forest vegetation in SW-sequence, where trees were only absent at the 63 and 14 years old abandonment sites. In all sites soils on level of reference groups according to WRB were classified, and Cambisols, Regosols, Calcisols, Leptosols, Chernozems and Phaeozems were found. Soils of the S-sequence show shallow remnants of loess cover with colluvic and redeposited soil materials containing 15-65% skeletal volcanic rock of weathering products coated by secondary calcium carbonates. The SW-sequence profiles are developed on deep loess or loess derivatives. The calcium-carbonate content was higher in profiles of

  18. Abdominal organ motion measured using 4D CT

    International Nuclear Information System (INIS)

    Brandner, Edward D.; Wu, Andrew; Chen, Hungcheng; Heron, Dwight; Kalnicki, Shalom; Komanduri, Krishna; Gerszten, Kristina; Burton, Steve; Ahmed, Irfan; Shou, Zhenyu

    2006-01-01

    Purpose: To measure respiration-induced abdominal organ motion using four-dimensional computed tomography (4D CT) scanning and to examine the organ paths. Methods and Materials: During 4D CT scanning, consecutive CT images are acquired of the patient at each couch position. Simultaneously, the patient's respiratory pattern is recorded using an external marker block taped to the patient's abdomen. This pattern is used to retrospectively organize the CT images into multiple three-dimensional images, each representing one breathing phase. These images are analyzed to measure organ motion between each phase. The displacement from end expiration is compared to a displacement limit that represents acceptable dosimetric results (5 mm). Results: The organs measured in 13 patients were the liver, spleen, and left and right kidneys. Their average superior to inferior absolute displacements were 1.3 cm for the liver, 1.3 cm for the spleen, 1.1 cm for the left kidney, and 1.3 cm for the right kidney. Although the organ paths varied among patients, 5 mm of superior to inferior displacement from end expiration resulted in less than 5 mm of displacement in the other directions for 41 of 43 organs measured. Conclusions: Four-dimensional CT scanning can accurately measure abdominal organ motion throughout respiration. This information may result in greater organ sparing and planning target volume coverage

  19. Determination of total and extractable hydrogen peroxide in organic and aqueous solutions of uranyl nitrate

    International Nuclear Information System (INIS)

    Goodall, Ph.

    1999-01-01

    The development of a spectrophotometric method for the determination of hydrogen peroxide in uranyl nitrate solutions is reported. The method involves the measurement of the absorbance at 520 mm of a vanadyl peroxide species. This species was formed by the addition of a reagent consisting of vanadium (V) (50 mmol x dm -3 ) in dilute sulphuric acid (2 mol x dm -3 H 2 SO 4 ). This reagent, after dilution, was also used as an extractant for organic phase samples. The method is simple and robust and tolerant of nitric acid and U(VI). Specificity and accuracy were improved by the application of solid phase extraction techniques to remove entrained organic solvents and Pu(VI). Reverse phase solid phase extraction was used to clean-up aqueous samples or extracts which were contaminated with entrained solvent. A solid phase extraction system based upon an extraction chromatography system was used to remove Pu(IV). Detection limits of 26 μmol x dm -3 (0.88 μg x cm -3 ) or 7 μmol x dm -3 (0.24 μg x cm -3 ) for, respectively, a 1 and 4 cm path length cell were obtained. Precisions of RSD = 1.4% and 19.5% were obtained at the extremes of the calibration curve (5 mmol x dm -3 and 50 μmol x dm -3 H 2 O 2 , 1 cm cell). The introduction of the extraction and clean-up stages had a negligible effect upon the precision of the determination. The stability of an organic phase sample was tested and no loss of analyte could be discerned over a period of at least 5 days. (author)

  20. Seismic based characterization of total organic content from the marine Sembar shale, Lower Indus Basin, Pakistan

    Science.gov (United States)

    Aziz, Omer; Hussain, Tahir; Ullah, Matee; Bhatti, Asher Samuel; Ali, Aamir

    2018-02-01

    The exploration and production of unconventional resources has increased significantly over the past few years around the globe to fulfill growing energy demands. Hydrocarbon potential of these unconventional petroleum systems depends on the presence of significant organic matter; their thermal maturity and the quality of present hydrocarbons i.e. gas or oil shale. In this work, we present a workflow for estimating Total Organic Content (TOC) from seismic reflection data. To achieve the objective of this study, we have chosen a classic potential candidate for exploration of unconventional reserves, the shale of the Sembar Formation, Lower Indus Basin, Pakistan. Our method includes the estimation of TOC from the well data using the Passey's ΔlogR and Schwarzkofp's methods. From seismic data, maps of Relative Acoustic Impedance (RAI) are extracted at maximum and minimum TOC zones within the Sembar Formation. A geostatistical trend with good correlation coefficient (R2) for cross-plots between TOC and RAI at well locations is used for estimation of seismic based TOC at the reservoir scale. Our results suggest a good calibration of TOC values from seismic at well locations. The estimated TOC values range from 1 to 4% showing that the shale of the Sembar Formation lies in the range of good to excellent unconventional oil/gas play within the context of TOC. This methodology of source rock evaluation provides a spatial distribution of TOC at the reservoir scale as compared to the conventional distribution generated from samples collected over sparse wells. The approach presented in this work has wider applications for source rock evaluation in other similar petroliferous basins worldwide.

  1. Assessment of ecotoxicity and total volatile organic compound (TVOC) emissions from food and children's toy products.

    Science.gov (United States)

    Szczepańska, Natalia; Marć, Mariusz; Kudłak, Błażej; Simeonov, Vasil; Tsakovski, Stefan; Namieśnik, Jacek

    2018-09-30

    The development of new methods for identifying a broad spectrum of analytes, as well as highly selective tools to provide the most accurate information regarding the processes and relationships in the world, has been an area of interest for researchers for many years. The information obtained with these tools provides valuable data to complement existing knowledge but, above all, to identify and determine previously unknown hazards. Recently, attention has been paid to the migration of xenobiotics from the surfaces of various everyday objects and the resulting impacts on human health. Since children are among those most vulnerable to health consequences, one of the main subjects of interest is the migration of low-molecular-weight compounds from toys and products intended for children. This migration has become a stimulus for research aimed at determining the degree of release of compounds from popular commercially available chocolate/toy sets. One of main objectives of this research was to determine the impact of time on the ecotoxicity (with Vibrio fischeri bioluminescent bacteria) of extracts of products intended for children and to assess the correlation with total volatile organic compound emissions using basic chemometric methods. The studies on endocrine potential (with XenoScreen YES/YAS) of the extracts and showed that compounds released from the studied objects (including packaging foils, plastic capsules storing toys, most of toys studied and all chocolate samples) exhibit mostly androgenic antagonistic behavior while using artificial saliva as extraction medium increased the impact observed. The impact of time in most cases was positive one and increased with prolonging extraction time. The small-scale stationary environmental test chambers - μ-CTE™ 250 system was employed to perform the studies aimed at determining the profile of total volatile organic compounds (TVOCs) emissions. Due to this it was possible to state that objects from which the

  2. 7S’s System Foundation of Total Productive Maintenance House for Lean Organization

    Directory of Open Access Journals (Sweden)

    Georgescu Daniel

    2009-12-01

    Full Text Available The goal of Lean TPM or TPM for lean organization approach is maintaining international competitiveness . This Lean TPM from our article, approach proposes tree additions to the current understanding of the TPM system: the 7Ss as a critical first step in any improvement program; instant maintenance; improvement setup operations. A company cannot make business gains solely by using cost-cutting measures because it cannot cost enough to become a world-class competitor. Instead, it must invest resources in productivity improvement. This generally increases factory throughput and cuts costs at the same time. Maintaining equipment in its optimal state and continually improving its productivity is the whole strategy behind TPM. The main objective of the 7S system is to grow the value added to each worker. To grow the added value, we must create ordered and well adjusted production lines based on the principles of the 7S’s: organization and order. Above all these two S’s bring to the factory standard positions and acknowledgement. Focus on the first two S’s brings a new perspective on understanding the 7S’s.

  3. Measurement of the total antioxidant response using a novel automated method in subjects with nonalcoholic steatohepatitis

    OpenAIRE

    Horoz, Mehmet; Bolukbas, Cengiz; Bolukbas, Fusun F; Sabuncu, Tevfik; Aslan, Mehmet; Sarifakiogullari, Serpil; Gunaydin, Necla; Erel, Ozcan

    2005-01-01

    Abstract Background Oxidative stress, an increase in oxidants and/or a decrease in antioxidant capacity, is one of the potential biochemical mechanisms involved in the pathogenesis of nonalcoholic steatohepatitis. We aimed to investigate the total antioxidant response using a novel automated method in nonalcoholic steatohepatitis subjects. As a reciprocal measure, we also aimed to determine total peroxide level in the same plasma samples. Methods Twenty-two subjects with biopsy proven nonalco...

  4. Development of an immunoradiometric method for the measurement of total PSA

    International Nuclear Information System (INIS)

    Venkatesh, M.; Korde, A.; Bapat, K.; Shukla, A.; Pillai, M.R.A.

    1999-01-01

    Development of an IRMA for total-PSA was taken up in our laboratories (Isotope Division, Bhabha Atomic Research Centre, Mumbai, India) and efforts were made to obtain monoclonals for PSA at our laboratory. Following the guidelines laid at the first meeting of this CRP we have used the reagents supplied by the Agency as well as our inhouse reagents, and attempted to develop assay procedures for measuring total-PSA in human sera

  5. Tropical intercontinental optical measurement network of aerosol, precipitable water and total column ozone

    Science.gov (United States)

    Holben, B. N.; Tanre, D.; Reagan, J. A.; Eck, T. F.; Setzer, A.; Kaufman, Y. A.; Vermote, E.; Vassiliou, G. D.; Lavenu, F.

    1992-01-01

    A new generation of automatic sunphotometers is used to systematically monitor clear sky total column aerosol concentration and optical properties, precipitable water and total column ozone diurnally and annually in West Africa and South America. The instruments are designed to measure direct beam sun, solar aureole and sky radiances in nine narrow spectral bands from the UV to the near infrared on an hourly basis. The instrumentation and the algorithms required to reduce the data for subsequent analysis are described.

  6. In vivo measurement of total body carbon using 238Pu/Be neutron sources

    International Nuclear Information System (INIS)

    Sutcliffe, J.F.; Mitra, S.; Hill, G.L.

    1990-01-01

    Total body carbon has been measured by in vivo neutron activation analysis (IVNAA) in 278 surgical gastroenterological patients and 29 normal volunteers. This is based on the inelastic scattering reaction { 12 C(n,n') 12 C*} for neutrons with energy above 4.8MeV, producing 4.43 MeV gamma rays. Since only part of the body is scanned, total body carbon is estimated as the ratio of the gamma ray emission from carbon to the emission from hydrogen, using hydrogen as the internal standard. The precision of the estimate is ±1.6kg for a whole body dose of 0.3mSv. There is a significant difference between the estimates of total body water from IVNAA measurements of carbon and nitrogen and measurements of body water in these subjects by tritium dilution (t=3.1, p < 0.005). (author)

  7. Suppression/reducing method for total organic carbon in feedwater/condensate

    International Nuclear Information System (INIS)

    Maeda, Katsuharu.

    1993-01-01

    The present invention suppresses/reduces the concentration of the total organic carbon before the startup of a reactor, to decrease (TOC) which is brought into the reactor upon startup of the operation and suppress/moderate degradation of water quality of reactor water. That is, in-service period of a condensate desalting tower is shortened, to avoid concentration increase of TOC in feed water/condensate which is leached out from the condensate desalting tower. The condensate desalting towers are put to in-service for the entire towers after increasing the vacuum degree of the condensator, to suppress leaching of TOC from the condensate desalting tower. Further, upon startup of a nuclear power plant, when the condensate desalting tower is put to in-service, condensate filters of the entire towers are previously back-washed and regenerated to remove TOC efficiently. By these procedures, TOC brought from a water supply system upon startup of the plant is thermally decomposed or radiolyzed in the reactor, thereby enabling to suppress/avoid worsening of water quality of reactor water caused by generated ion impurities. (I.S.)

  8. Symptoms of mothers and infants related to total volatile organic compounds in household products.

    Science.gov (United States)

    Farrow, Alexandra; Taylor, Hazel; Northstone, Kate; Golding, Jean

    2003-10-01

    The authors sought to determine whether reported symptoms of mothers and infants were associated significantly with the use of household products that raised indoor levels of total volatile organic compounds (TVOCs). Data collected from 170 homes within the Avon Longitudinal Study of Parents and Children (ALSPAC: a large birth cohort of more than 10,000) had determined which household products were associated with the highest levels of TVOCs. The latter data were collected over a period that approximated 6 mo of pregnancy and the infants' first 6 mo of life. This paper presents (a) the mothers' self-reports of the use of these products in their homes and (b) self-reported medical symptoms of mothers and infants postnatally. Higher TVOC levels were associated with air freshener and aerosol use. Infant diarrhea and earache were statistically significantly associated with air freshener use, and diarrhea and vomiting were significantly associated with aerosol use. Headache experienced by mothers 8 mo after birth was significantly associated with the use of air fresheners and aerosols; maternal depression was significantly associated with the use of air fresheners. The results of the study suggest a link between the use of products that raise indoor levels of TVOCs and an increased risk of certain symptoms among infants and their mothers.

  9. Frustrated total internal reflection in organic light-emitting diodes employing sphere cavity embedded in polystyrene

    International Nuclear Information System (INIS)

    Zhu, Peifen

    2016-01-01

    The light extraction efficiency of top-emitting organic light-emitting diodes (OLEDs) is numerically investigated employing the finite-difference time-domain method. The periodic nanostructures formed by embedding the sphere arrays in polystyrene (PS) are placed on top of OLED to frustrate the total internal reflection at the interface between OLED and free space. These nanostructures serve as an intermediate medium to extract the light out of OLED devices. Efficiently coupling both evanescent waves and propagation waves into spheres and subsequently extracting these light waves out of the sphere is key to achieving high extraction efficiency. By tuning the thickness of PS layer, both of the in-coupling efficiency and out-coupling efficiency are optimized for achieving high light extraction efficiency. Thicker PS layer results in higher in-coupling efficiency in sphere while the thinner PS layer leads to higher out-coupling efficiency. Thus the maximum light extraction is a trade-off between the in-coupling efficiency and out-coupling efficiency. The study shows that light extraction efficiency of 89% can be achieved by embedding 0.90 μm TiO 2 sphere in 0.30 μm PS layer with optimized in-coupling efficiency, out-coupling efficiency and cavity effect. (paper)

  10. [Accumulation of soil organic carbon and total nitrogen in Pinus yunnanensis forests at different age stages].

    Science.gov (United States)

    Miao, Juan; Zhou, Chuan-Yan; Li, Shi-Jie; Yan, Jun-Hua

    2014-03-01

    Taking three Pinus yunnanensis forests at different ages (19, 28 and 45 a) in Panxian County of Guizhou Province as test objects, we investigated vertical distributions and accumulation rates of soil organic carbon (SOC) and total nitrogen (TN), as well as their relationships with soil bulk density. For the three forests at different age stages, SOC and TN changed consistently along the soil profile, declining with the soil depth. Both SOC and TN storage increased with the forest age. The SOC and TN storage amounts were 96.24, 121.65 and 148.13 t x hm(-2), and 10.76, 12.96 and 13.08 t x hm(-2) for the forest stands with 19 a, 28 a and 45 a, respectively. SOC had a significant positive correlation with soil TN, while both of them had a significant negative relationship with the soil bulk density. The accumulation rates of both SOC and TN storage at different growth periods were different, and the rate in the period from age 19 to 28 was higher than in the period from age 28 to 45.

  11. Assessment of bacterial growth and total organic carbon removal on granular activated carbon contactors.

    Science.gov (United States)

    Bancroft, K; Maloney, S W; McElhaney, J; Suffet, I H; Pipes, W O

    1983-01-01

    The overall growth rate of bacteria on granular activated carbon (GAC) contactors at the Philadelphia Torresdale Water Treatment Pilot Plant facility was found to decrease until steady state was reached. The growth rate was found to fluctuate between 6.94 X 10(-3) and 8.68 X 10(-4) doublings per h. The microbiological removal of total organic carbon (TOC) was calculated by considering the GAC contactors as semiclosed continuous culture systems and using growth yield factors determined in laboratory experiments. After ozonation, the average TOC entering the contactors was 1,488 micrograms/liter, and the average effluent TOC was 497 micrograms/liter. Microbiological TOC removal was found to average 240 micrograms/liter on GAC contactors, which was not significantly different from microbiological TOC (220 micrograms/liter) removal across a parallel sand contactor where no adsorption took place. Thus, GAC did not appear to enhance biological TOC removal. Bacterial growth and maintenance was responsible for approximately 24% of the TOC removal on GAC under the conditions of this study. PMID:6639023

  12. [Impact of air fresheners and deodorizers on the indoor total volatile organic compounds].

    Science.gov (United States)

    Jinno, Hideto; Tanaka-Kagawa, Toshiko; Obama, Tomoko; Miyagawa, Makoto; Yoshikawa, Jun; Komatsu, Kazuhiro; Tokunaga, Hiroshi

    2007-01-01

    Indoor air quality is a growing health concern because of the increased incidence of the building-related illness, such as sick-building syndrome and multiple chemical sensitivity/idiopathic environmental intolerance. In order to effectively reduce the unnecessary chemical exposure in the indoor environment, it would be important to quantitatively compare the emissions from many types of sources. Besides the chemical emissions from the building materials, daily use of household products may contribute at significant levels to the indoor volatile organic compounds (VOCs). In this study, we investigated the emission rate of VOCs and carbonyl compounds for 30 air fresheners and deodorizers by the standard small chamber test method (JIS A 1901). The total VOC (TVOC) emission rates of these household products ranged from the undetectable level (fragrances in the products account for the major part of the TVOC emissions. Based on the emission rates, the impacts on the indoor TVOC were estimated by the simple model with a volume of 17.4 m3 and a ventilation frequency of 0.5 times/h. The mean of the TVOC increment for the indoor air fresheners was 170 microg/m3, accounting for 40% of the current provisional target value, 400 microg/m3. These results suggest that daily use of household products can significantly influence the indoor air quality.

  13. Assessment of bacterial growth and total organic carbon removal on granular activated carbon contactors.

    Science.gov (United States)

    Bancroft, K; Maloney, S W; McElhaney, J; Suffet, I H; Pipes, W O

    1983-09-01

    The overall growth rate of bacteria on granular activated carbon (GAC) contactors at the Philadelphia Torresdale Water Treatment Pilot Plant facility was found to decrease until steady state was reached. The growth rate was found to fluctuate between 6.94 X 10(-3) and 8.68 X 10(-4) doublings per h. The microbiological removal of total organic carbon (TOC) was calculated by considering the GAC contactors as semiclosed continuous culture systems and using growth yield factors determined in laboratory experiments. After ozonation, the average TOC entering the contactors was 1,488 micrograms/liter, and the average effluent TOC was 497 micrograms/liter. Microbiological TOC removal was found to average 240 micrograms/liter on GAC contactors, which was not significantly different from microbiological TOC (220 micrograms/liter) removal across a parallel sand contactor where no adsorption took place. Thus, GAC did not appear to enhance biological TOC removal. Bacterial growth and maintenance was responsible for approximately 24% of the TOC removal on GAC under the conditions of this study.

  14. FERTILITY AND TOTAL ORGANIC CARBON IN OXISOL UNDER DIFFERENT MANAGEMENT SYSTEMS IN SAVANNAH OF PIAUÍ, BRAZIL

    Directory of Open Access Journals (Sweden)

    Fernando Silva Araújo

    2017-05-01

    Full Text Available The intensive use of natural resources for food production has ruptured the sustainability of agro-ecosystems. In this context, this study aimed to quantify chemical attributes of Oxisol under five management systems: 1 = conventional tillage (CT; 2 = no-tillage system with millet (NT + M; 3 = crop–livestock integration system with soybean (CL + S; 4 = CL with pasture (CL + P; and 5 = native forest (NF. The following soil depths were studied: 0.00–0.05, 0.05–0.10, and 0.10–0.20 m; and the following traits were quantified: total organic carbon (TOC, soil acidity (pH, soil potential acidity (H + Al and soil fertility (Ca, Mg, P and K. All treatments modified soil chemical attributes in comparison to NF (p <0.01. The highest phosphorus and potassium levels were observed under CL + S at all evaluated depths. The NT + M treatment increased Ca and Mg levels in layers 0.0–0.05 and 0.10–0.20, whereas CL + S increased base addition (BA, cation exchange capacity (CEC and  base saturation (BS levels in layer 0.05–0.10 m. Finally, both CL systems improved soil chemical quality, increased surface TOC and carbon stock in depth.

  15. High purity heavy water production: need for total organic carbon determination in process water streams

    International Nuclear Information System (INIS)

    Ayushi; Kumar, Sangita D.; Reddy, A.V.R.; Vithal, G.K.

    2009-01-01

    In recent times, demand for high purity heavy water (99.98% pure) in industries and laboratories has grown by manifold. Its application started in nuclear industry with the design of CANDU reactor, which uses natural uranium as fuel. In this reactor the purest grade of heavy water is used as the moderator and the primary coolant. Diverse industrial applications like fibre optics, medicine, semiconductors etc. use high purity heavy water extensively to achieve better performance of the specific material. In all these applications there is a stringent requirement that the total organic carbon content (TOC) of high purity heavy water should be very low. This is because the presence of TOC can lead to adverse interactions in different applications. To minimize the TOC content in the final product there is a need to monitor and control the TOC content at each and every stage of heavy water production. Hence a simple, rapid and accurate method was developed for the determination of TOC content in process water samples. The paper summarizes the results obtained for the TOC content in the water samples collected from process streams of heavy water production plant. (author)

  16. Basin-scale changes of total organic carbon profiles in the eastern South Atlantic

    Directory of Open Access Journals (Sweden)

    X. A. Alvarez-Salgado

    2001-03-01

    Full Text Available Total organic carbon (TOC samples were collected at 6 stations spaced ~800 km apart in the eastern South Atlantic, from the Equator to 45°S along 9°W. Analyses were performed by high temperature catalytic oxidation (HTCO in the base laboratory. Despite the complex advection and mixing patterns of North Atlantic and Antarctic waters with extremely different degrees of ventilation, TOC levels below 500 m are quasi-constant at 55±3 µmol C l-1, pointing to the refractory nature of deep-water TOC. On the other hand, a TOC excess from 25 to 38 g C m-2 is observed in the upper 100 m of the permanently stratified nutrient-depleted Equatorial, Subequatorial and Subtropical upper ocean, where vertical turbulent diffusion is largely prevented. Conversely, TOC levels in the nutrient-rich upper layer of the Subantarctic Front only exceeds 9 g C m-2 the deep-water baseline. As much as 70% of the TOC variability in the upper 500 m is due to simple mixing of reactive TOC formed in the surface layer and refractory TOC in deep ocean waters, with a minor contribution (13% to oxygen consumption in the prominent subsurface AOU maximum at 200-400 m depth.

  17. Comparison of biuret and refractometry methods for the serum total proteins measurement in ruminants.

    Science.gov (United States)

    Katsoulos, Panagiotis D; Athanasiou, Labrini V; Karatzia, Maria A; Giadinis, Nektarios; Karatzias, Harilaos; Boscos, Constantin; Polizopoulou, Zoe S

    2017-12-01

    Determination of serum total protein concentration is commonly performed by the biuret method. Refractometric measurement is a faster and less expensive alternative but its accuracy has not been determined in ruminants. The purpose of the study was to compare the serum total protein concentrations in cattle, sheep, and goats measured by the biuret method with those obtained by refractometry. Serum total protein concentration was determined in 120 cattle, 67 sheep, and 58 goat blood samples refractometrically and with the biuret method. The data were analyzed with a paired samples t-test, and Passing and Bablok regression equations and Bland and Altman plots were generated. There was a strong linear relationship between the total protein values determined with the refractometer and the biuret method in cattle, sheep, and goats. The statistical accuracy, which represents a bias correction factor that measures the deviation of the best-fit line from the 45° line through the origin, was 90.63% for cattle, 93.05% for sheep, and 91.76% for goats. The mean protein values determined with the refractometer were significantly lower than those measured with the biuret method in cattle and goats (P  .05). The evaluated refractometer was sufficiently accurate for the determination of serum total proteins in cattle, sheep, and goats, although it cannot be used interchangeably with the biuret method. The RIs should be corrected for negative bias based on the created equations. © 2017 American Society for Veterinary Clinical Pathology.

  18. Measurement of oxygen transfer from air into organic solvents

    DEFF Research Database (Denmark)

    Ramesh, Hemalata; Mayr, Torsten; Hobisch, Mathias

    2016-01-01

    biological reactions require the supply of oxygen, most normally from air. However, reliable on-line measurements of oxygen concentration in organic solvents (and hence oxygen transfer rates from air to the solvent) has to date proven impossible due limitations in the current analytical methods. Results...... applications). Subsequently, we measured the oxygen transfer rates from air into these organic solvents. Conclusion The measurement of oxygen transfer rates from air into organic solvents using the dynamic method was established using the solvent resistant optical sensor. The feasibility of online oxygen...... For the first time, we demonstrate on-line oxygen measurements in non-aqueous media using a novel optical sensor. The sensor was used to measure oxygen concentration in various organic solvents including toluene, THF, isooctane, DMF, heptane and hexane (which have all been shown suitable for several biological...

  19. Chapter 4: Measurements of total beta-activity in the fallout

    International Nuclear Information System (INIS)

    Duggleby, J.C.; Johannessen, J.C.; Kotler, L.H.; Stewart, F.M.

    1974-01-01

    In order to provide information on fresh fission products in fallout reaching Australia from nuclear tests being conducted by France in Polynesia, measurements were made of total beta activity in daily fallout deposition of 25 Australian sampling stations covering a three month period from 25 July to 23 October 1973. The methods employed to measure the radioactivity of the samples are described and the data on total beta-activity, and the calculated external gamma radiation doses from fresh fallout are presented. (R.L.)

  20. Measurement of Organ Uptake by Whole-Body Counting

    International Nuclear Information System (INIS)

    Dudley, R.A.

    1970-01-01

    This paper reviews methods for the measurement of radioactivity in body organs based on whole-body radioactivity measurements. Such measurements can of course only be used to measure radioactivity in a body organ when the radioactivity is exclusively localized in the organ or when the ratio of radioactivity in the organ to that in the whole body is known from other sources of information. They find particular applications, however, when the organ is so widely dispersed throughout the body that more localized measurement is impossible. Examples of situations in which whole-body radioactivity measurements have been used in this way are cited. The more important techniques used for such measurements are described and their respective advantages and disadvantages indicated. The importance of uniformity of counting efficiency with position of source throughout the body is stressed. Simple systems incorporating sodium iodide crystal scintillation detectors are shown to combine satisfactory sensitivity and uniformity of efficiency for clinical measurements of radioactivity in body organs and have the additional advantage that they can be readily adapted for profile scanning. Systems incorporating plastic or liquid scintillation detectors are less convenient in this respect. (author)

  1. Fourier transform infrared spectroscopy, a new method for rapid determination of total organic and inorganic carbon and biogenic silica concentration in lake sediments

    DEFF Research Database (Denmark)

    Rosén, Peter; Vogel, Hendrik; Cunningham, Laura

    2010-01-01

    We demonstrate the use of Fourier transform infrared spectroscopy (FTIRS) to make quantitative measures of total organic carbon (TOC), total inorganic carbon (TIC) and biogenic silica (BSi) concentrations in sediment. FTIRS is a fast and cost-effective technique and only small sediment samples...... varied between r = 0.84-0.99 for TOC, r = 0.85-0.99 for TIC, and r = 0.68-0.94 for BSi. Because FTIR spectra contain information on a large number of both inorganic and organic components, there is great potential for FTIRS to become an important tool in paleolimnology....

  2. Measurement of Neutron Total Cross Sections in Support of the APT Program

    International Nuclear Information System (INIS)

    Abfalterer, W.P.; Haight, R.C.; Morgan, G.L.; Bateman, F.B.; Dietrich, F.S.; Finlay, R.W.

    1998-01-01

    The authors have completed a new set of total cross section measurements of 37 samples spanning the periodic table. The authors employed the same technique as in a previous measurement, with refinements intended to allow measurements on separated isotopes, and with improved systematic error control. The goal of the new measurement was 1% statistical accuracy in 1% energy bins with systematic errors less than 1%. This was achieved for all but the smallest samples, for which the statistical accuracy was as large as 2% in 1% bins

  3. Measurement with total scatter calibrate factor at different depths in the calculation of prescription dose

    International Nuclear Information System (INIS)

    Li Lijun; Zhu Haijun; Zhang Xinzhong; Li Feizhou; Song Hongyu

    2004-01-01

    Objective: To evaluate the method of measurement of total scatter calibrate factor (Sc, p). Methods: To measure the Sc, p at different depths on central axis of 6MV, 15MV photon beams through different ways. Results: It was found that the measured data of Sc, p changed with the different depths to a range of 1% - 7%. Using the direct method, the Sc, p measured depth should be the same as the depth in dose normalization point of the prescription dose. If the Sc, p (fsz, d) was measured at the other depths, it could be obtained indirectly by the calculation formula. Conclusions: The Sc, p in the prescription dose can be obtained either by the direct measure method or the indirect calculation formula. But emphasis should be laid on the proper measure depth. (authors)

  4. Vitamin D metabolites in captivity? Should we measure free or total 25(OH)D to assess vitamin D status?

    Science.gov (United States)

    Bikle, Daniel; Bouillon, Roger; Thadhani, Ravi; Schoenmakers, Inez

    2017-10-01

    There is general consensus that serum 25(OH)D is the best biochemical marker for nutritional vitamin D status. Whether free 25(OH)D would be a better marker than total 25(OH)D is so far unclear. Free 25(OH)D can either be calculated based on the measurement of the serum concentrations of total 25(OH)D, vitamin D-binding protein (DBP), albumin, and the affinity between 25(OH)D and its binding proteins in physiological situations. Free 25(OH)D can also be measured directly by equilibrium dialysis, ultrafitration or immunoassays. During the vitamin D workshop held in Boston in March 2016, a debate was organized about the measurements and clinical value of free 25(OH)D, and this debate is summarized in the present manuscript. Overall there is consensus that most cells apart from the renal tubular cells are exposed to free rather than to total 25(OH)D. Therefore free 25(OH)D may be highly relevant for the local production and action of 1,25(OH) 2 D. During the debate it became clear that there is a need for standardization of measurements of serum DBP and of direct measurements of free 25(OH)D. There seems to be very limited genetic or racial differences in DBP concentrations or (probably) in the affinity of DBP for its major ligands. Therefore, free 25(OH)D is strongly correlated to total 25(OH)D in most normal populations. Appropriate studies are needed to define the clinical implications of free rather than total 25(OH)D in normal subjects and in disease states. Special attention is needed for such studies in cases of abnormal DBP concentrations or when one could expect changes in its affinity for its ligands. Copyright © 2017. Published by Elsevier Ltd.

  5. Utility of noninvasive transcutaneous measurement of postoperative hemoglobin in total joint arthroplasty patients.

    Science.gov (United States)

    Stoesz, Michael; Wood, Kristin; Clark, Wesley; Kwon, Young-Min; Freiberg, Andrew A

    2014-11-01

    This study prospectively evaluated the clinical utility of a noninvasive transcutaneous device for postoperative hemoglobin measurement in 100 total hip and knee arthroplasty patients. A protocol to measure hemoglobin noninvasively, prior to venipuncture, successfully avoided venipuncture in 73% of patients. In the remaining 27 patients, there were a total of 48 venipunctures performed during the postoperative hospitalization period due to reasons including transcutaneous hemoglobin measurement less than or equal to 9 g/dL (19), inability to obtain a transcutaneous hemoglobin measurement (8), clinical signs of anemia (3), and noncompliance with the study protocol (18). Such screening protocols may provide a convenient and cost-effective alternative to routine venipuncture for identifying patients at risk for blood transfusion after elective joint arthroplasty. Copyright © 2014 Elsevier Inc. All rights reserved.

  6. Total body-calcium measurements: comparison of two delayed-gamma neutron activation facilities

    International Nuclear Information System (INIS)

    Ma, R.; Ellis, K.J.; Shypailo, R.J.; Pierson, R.N. Jr.

    1999-01-01

    This study compares two independently calibrated delayed-gamma neutron activation (DGNA) facilities, one at the Brookhaven National Laboratory (BNL), Upton, New York, and the other at the Children's Nutrition Research Center (CNRC), Houston, Texas that measure total body calcium (TBCa). A set of BNL phantoms was sent to CNRC for neutron activation analysis, and a set of CNRC phantoms was measured at BNL. Both facilities showed high precision (<2%), and the results were in good agreement, within 5%. (author)

  7. The nTOF Total Absorption Calorimeter for neutron capture measurements at CERN

    International Nuclear Information System (INIS)

    Guerrero, C.; Abbondanno, U.; Aerts, G.; Alvarez, H.; Alvarez-Velarde, F.; Andriamonje, S.; Andrzejewski, J.; Assimakopoulos, P.; Audouin, L.; Badurek, G.; Baumann, P.; Becvar, F.; Berthoumieux, E.; Calvino, F.; Calviani, M.; Cano-Ott, D.; Capote, R.; Carrapico, C.; Cennini, P.; Chepel, V.

    2009-01-01

    The n T OF Collaboration has built and commissioned a high-performance detector for (n,γ) measurements called the Total Absorption Calorimeter (TAC). The TAC was especially designed for measuring neutron capture cross-sections of low-mass and/or radioactive samples with the accuracy required for nuclear technology and stellar nucleosynthesis. We present a detailed description of the TAC and discuss its overall performance in terms of energy and time resolution, background discrimination, detection efficiency and neutron sensitivity.

  8. Total water, phosphorus relaxation and inter-atomic organic to inorganic interface are new determinants of trabecular bone integrity.

    Directory of Open Access Journals (Sweden)

    Ratan Kumar Rai

    Full Text Available Bone is the living composite biomaterial having unique structural property. Presently, there is a considerable gap in our understanding of bone structure and composition in the native state, particularly with respect to the trabecular bone, which is metabolically more active than cortical bones, and is readily lost in post-menopausal osteoporosis. We used solid-state nuclear magnetic resonance (NMR to compare trabecular bone structure and composition in the native state between normal, bone loss and bone restoration conditions in rat. Trabecular osteopenia was induced by lactation as well as prolonged estrogen deficiency (bilateral ovariectomy, Ovx. Ovx rats with established osteopenia were administered with PTH (parathyroid hormone, trabecular restoration group, and restoration was allowed to become comparable to sham Ovx (control group using bone mineral density (BMD and µCT determinants. We used a technique combining (1H NMR spectroscopy with (31P and (13C to measure various NMR parameters described below. Our results revealed that trabecular bones had diminished total water content, inorganic phosphorus NMR relaxation time (T1 and space between the collagen and inorganic phosphorus in the osteopenic groups compared to control, and these changes were significantly reversed in the bone restoration group. Remarkably, bound water was decreased in both osteopenic and bone restoration groups compared to control. Total water and T1 correlated strongly with trabecular bone density, volume, thickness, connectivity, spacing and resistance to compression. Bound water did not correlate with any of the microarchitectural and compression parameters. We conclude that total water, T1 and atomic space between the crystal and organic surface are altered in the trabecular bones of osteopenic rats, and PTH reverses these parameters. Furthermore, from these data, it appears that total water and T1 could serve as trabecular surrogates of micro-architecture and

  9. Helium Mass Spectrometer Leak Detection: A Method to Quantify Total Measurement Uncertainty

    Science.gov (United States)

    Mather, Janice L.; Taylor, Shawn C.

    2015-01-01

    In applications where leak rates of components or systems are evaluated against a leak rate requirement, the uncertainty of the measured leak rate must be included in the reported result. However, in the helium mass spectrometer leak detection method, the sensitivity, or resolution, of the instrument is often the only component of the total measurement uncertainty noted when reporting results. To address this shortfall, a measurement uncertainty analysis method was developed that includes the leak detector unit's resolution, repeatability, hysteresis, and drift, along with the uncertainty associated with the calibration standard. In a step-wise process, the method identifies the bias and precision components of the calibration standard, the measurement correction factor (K-factor), and the leak detector unit. Together these individual contributions to error are combined and the total measurement uncertainty is determined using the root-sum-square method. It was found that the precision component contributes more to the total uncertainty than the bias component, but the bias component is not insignificant. For helium mass spectrometer leak rate tests where unit sensitivity alone is not enough, a thorough evaluation of the measurement uncertainty such as the one presented herein should be performed and reported along with the leak rate value.

  10. Measurements of total cross sections between 23 and 280 GeV/c

    International Nuclear Information System (INIS)

    Koehler, P.F.M.

    1975-01-01

    The high precision measurements of the total cross sections for π/sup +-/, K/sup +-/, p, and anti p scattering from H 2 and D 2 were continued with an extension of the energy range from 23 to 280 GeV/c

  11. Perceptions of Community College Presidents: Total Quality Management Performance Measures at Their Colleges

    Science.gov (United States)

    Riccardi, Mark T.

    2009-01-01

    Continuous Quality Improvement (CQI) measures such as Total Quality Management (TQM), Strategic Planning, Six Sigma, and the Balanced Scorecard are often met with skepticism among leaders of higher education. This study attempts to fill a gap in the literature regarding the study of relationships among specific variables, or building blocks,…

  12. Measurement of the π- proton total cross section from 5 to 15 GeV/c

    International Nuclear Information System (INIS)

    Lelouch, Daniel.

    1979-01-01

    An original method for total cross-section measurement based on a fast microcomputer processing events on line is described. An excellent accuracy is reached by a systematical control of numerous biases. It is shown that the experiment is a first approach to the study of narrow baryonic resonances a multiquark states ('color chemics') [fr

  13. Measurement methods and variability assessment of the Norway spruce total leaf area: Implications for remote sensing

    NARCIS (Netherlands)

    Homolova, L.; Lukes, P.; Malenovsky, Z.; Lhotakova, Z.; Kaplan, V.; Hanus, J.

    2013-01-01

    Estimation of total leaf area (LAT) is important to express biochemical properties in plant ecology and remote sensing studies. A measurement of LAT is easy in broadleaf species, but it remains challenging in coniferous canopies. We proposed a new geometrical model to estimate Norway spruce LAT and

  14. The construction of distant total distributed measuring and controlling system based on RS-232 communication

    International Nuclear Information System (INIS)

    Shi Chengying; Li Tiantuo; Zhu Wenkai; Zhang Quanhu

    1999-01-01

    The author discusses the construction of distant total distributed measuring and controlling system based on RS-232 communication. The merits of this system are simple construction, reliable performance, big communication distance, and wide covering range. The system fits in with application in radiation environment. The author also discusses the system's hardware equipment and communication protocol

  15. Objectively measured total and occupational sedentary time in three work settings

    NARCIS (Netherlands)

    Dommelen, P. van; Coffeng, J. K.; Ploeg, H.P. van der; Beek, A.J. van der; Boot, C.R.; Hendriksen, I.J.

    2016-01-01

    Background. Sedentary behaviour increases the risk for morbidity. Our primary aim is to determine the proportion and factors associated with objectively measured total and occupational sedentary time in three work settings. Secondary aim is to study the proportion of physical activity and prolonged

  16. Distribution of surficial sediment in Long Island Sound and adjacent waters: Texture and total organic carbon

    Science.gov (United States)

    Poppe, L.J.; Knebel, H.J.; Mlodzinska, Z.J.; Hastings, M.E.; Seekins, B.A.

    2000-01-01

    The surficial sediment distribution within Long Island Sound has been mapped and described using bottom samples, photography, and sidescan sonar, combined with information from the geologic literature. The distributions of sediment type and total organic carbon (TOC) reveal several broad trends that are largely related to the sea-floor geology, the bathymetry, and the effects of modern tidal- and wind-driven currents. Sediment types are most heterogeneous in bathymetrically complex and shallow nearshore areas; the heterogeneity diminishes and the texture fines with decreasing bottom-current energy. Lag deposits of gravel and gravelly sand dominate the surficial sediment texture in areas where bottom currents are the strongest (such as where tidal flow is constricted) and where glacial till crops out at the sea floor. Sand is the dominant sediment type in areas characterized by active sediment transport and in shallow areas affected by fine-grained winnowing. Silty sand and sand-silt-clay mark transitions within the basin from higher- to lower-energy environments, suggesting a diminished hydraulic ability to sort and transport sediment. Clayey silt and silty clay are the dominant sediment types accumulating in the central and western basins and in other areas characterized by long-term depositional environments. The amount of TOC in the sediments of Long Island Sound varies inversely with sediment grain size. Concentrations average more than 1.9% (dry weight) in clayey silt, but are less than 0.4% in sand. Generally, values for TOC increase both toward the west in the Sound and from the shallow margins to the deeper parts of the basin floor. Our data also suggest that TOC concentrations can vary seasonally.

  17. Expected total counts for the Self-Interrogation Neutron Resonance Densitometry measurements of spent nuclear fuel

    Energy Technology Data Exchange (ETDEWEB)

    Rossa, Riccardo [Belgian nuclear research centre SCK.CEN (Belgium); Universite Libre de Bruxelles (Belgium); Borella, Alessandro; Van der Meer, Klaas [Belgian nuclear research centre SCK.CEN. Boeretang 200, 2400 Mol (Belgium); Labeau, Pierre-Etienne; Pauly, Nicolas [Universite Libre de Bruxelles. Av. F. D. Roosevelt 50, B1050 Brussels (Belgium)

    2015-07-01

    The Self-Interrogation Neutron Resonance Densitometry (SINRD) is a passive neutron technique that aims at a direct quantification of {sup 239}Pu in spent fuel assemblies by measuring the attenuation of the neutron flux in the energy region close to the 0.3 eV resonance of {sup 239}Pu. The {sup 239}Pu mass is estimated by calculating the SINRD signature, that is the ratio between the neutron counts in the fast energy region and around the 0.3 eV resonance region. The SINRD measurement approach in this study consisted in introducing a small neutron detector in the central guide tube of a PWR 17x17 fuel assembly. In order to measure the neutron flux in the energy regions defined in the SINRD signature, different detector types were used. The response of a bare {sup 238}U fission chamber is considered for the determination of the fast neutron flux, while other thermal-epithermal detectors wrapped in neutron absorbers are envisaged to measure the neutron flux around the resonance region. This paper provides an estimation of the total neutron counts that can be achieved with the detector types proposed for the SINRD measurement. In the first section a set of detectors are evaluated in terms of total neutron counts and sensitivity to the {sup 239}Pu content, in order to identify the optimal measurement configuration for each detector type. Then a study is performed to increase the total neutron counts by increasing the detector size. The study shows that the highest total neutron counts are achieved by using either {sup 3}He or {sup 10}B proportional counters because of the high neutron efficiency of these detectors. However, the calculations indicate that the biggest contribution to the measurement uncertainty is due to the measurement of the fast neutron flux. Finally, similar sensitivity to the {sup 239}Pu content is obtained by using the different detector types for the measurement of the neutron flux close to the resonance region. Therefore, the total neutron counts

  18. Measurements of the Total, Elastic, Inelastic and Diffractive Cross Sections with the ATLAS Detector

    CERN Document Server

    AUTHOR|(INSPIRE)INSPIRE-00237700; The ATLAS collaboration

    2016-01-01

    The main results of the total, elastic and inelastic cross sections measurements performed by the ATLAS ALFA detectors are presented. The independent inelastic cross section measurement done using Minimum Bias Trigger Scintillators is also shown. Next, the single diffractive di-jet production and gap survival probability are briefly described. After the event selection, it was found that the diffractive component is needed for a more complete description of data. Finally, the exclusive lepton pair production analysis in electron and muon channels is also described. The measured cross sections were found to be consistent with the theory prediction.

  19. Geometric measure of quantum discord and total quantum correlations in an N-partite quantum state

    International Nuclear Information System (INIS)

    Hassan, Ali Saif M; Joag, Pramod S

    2012-01-01

    Quantum discord, as introduced by Ollivier and Zurek (2001 Phys. Rev. Lett. 88 017901), is a measure of the discrepancy between quantum versions of two classically equivalent expressions for mutual information and is found to be useful in quantification and application of quantum correlations in mixed states. It is viewed as a key resource present in certain quantum communication tasks and quantum computational models without containing much entanglement. An early step toward the quantification of quantum discord in a quantum state was by Dakic et al (2010 Phys. Rev. Lett. 105 190502) who introduced a geometric measure of quantum discord and derived an explicit formula for any two-qubit state. Recently, Luo and Fu (2010 Phys. Rev. A 82 034302) introduced a generic form of the geometric measure of quantum discord for a bipartite quantum state. We extend these results and find generic forms of the geometric measure of quantum discord and total quantum correlations in a general N-partite quantum state. Further, we obtain computable exact formulas for the geometric measure of quantum discord and total quantum correlations in an N-qubit quantum state. The exact formulas for the N-qubit quantum state can be used to get experimental estimates of the quantum discord and the total quantum correlation. (paper)

  20. ATLAS-ALFA measurements on the total cross section and diffraction

    CERN Document Server

    Mortensen, Simon Stark; The ATLAS collaboration

    2015-01-01

    The measurement of the total pp cross section at the LHC at $\\sqrt{s}=7$ TeV with the ALFA subdetector of ATLAS is presented in this talk. In a special run with $\\beta^*=90$ m beam optics corresponding to an integrated luminosity of 80 $\\text{mb}^{-1}$ the differential elastic cross section is measured in the range from $-t=0.0025\\text{ GeV}^2$ to $-t=0.38\\text{ GeV}^2$. The total cross section $\\sigma(pp\\rightarrow X)$ is extracted using the Optical Theorem by extrapolation of the differential elastic cross section to $t=0\\text{ GeV}^2$. Prospects for diffractive measurements using ALFA to detect the intact proton(s) is also discussed.

  1. Total Measurement Uncertainty for the Plutonium Finishing Plant (PFP) Segmented Gamma Scan Assay System

    CERN Document Server

    Fazzari, D M

    2001-01-01

    This report presents the results of an evaluation of the Total Measurement Uncertainty (TMU) for the Canberra manufactured Segmented Gamma Scanner Assay System (SGSAS) as employed at the Hanford Plutonium Finishing Plant (PFP). In this document, TMU embodies the combined uncertainties due to all of the individual random and systematic sources of measurement uncertainty. It includes uncertainties arising from corrections and factors applied to the analysis of transuranic waste to compensate for inhomogeneities and interferences from the waste matrix and radioactive components. These include uncertainty components for any assumptions contained in the calibration of the system or computation of the data. Uncertainties are propagated at 1 sigma. The final total measurement uncertainty value is reported at the 95% confidence level. The SGSAS is a gamma assay system that is used to assay plutonium and uranium waste. The SGSAS system can be used in a stand-alone mode to perform the NDA characterization of a containe...

  2. Measurement of total risk of spontaneous abortion: the virtue of conditional risk estimation

    DEFF Research Database (Denmark)

    Modvig, J; Schmidt, L; Damsgaard, M T

    1990-01-01

    The concepts, methods, and problems of measuring spontaneous abortion risk are reviewed. The problems touched on include the process of pregnancy verification, the changes in risk by gestational age and maternal age, and the presence of induced abortions. Methods used in studies of spontaneous...... abortion risk include biochemical assays as well as life table technique, although the latter appears in two different forms. The consequences of using either of these are discussed. It is concluded that no study design so far is appropriate for measuring the total risk of spontaneous abortion from early...... conception to the end of the 27th week. It is proposed that pregnancy may be considered to consist of two or three specific periods and that different study designs should concentrate on measuring the conditional risk within each period. A careful estimate using this principle leads to an estimate of total...

  3. Measurement of thyroid volume, iodine concentration and total iodine content by CT and its clinical significance

    International Nuclear Information System (INIS)

    Nakaji, Shunsuke; Imanishi, Yoshimasa; Okamoto, Kyouko; Shinagawa, Toshihito

    2007-01-01

    Recently, Imanishi et al have developed new CT software for quantitative in vivo measurement of thyroid iodine. Using a CT system with the software, we measured volume, iodine concentration and total iodine content of thyroids in 63 controls and 435 patients with various diffuse thyroid diseases and thyroid nodules. In controls, all of them showed no difference between the sexes. Although the iodine concentration of the thyroid showed no difference among children, adults and seniles, the volume and total iodine content of the thyroid appeared smaller in children and seniles than in adults. In addition, although the volume and iodine concentration of the thyroid had two peaks in distribution, the total iodine content had almost normal distribution. Normal range of volume, iodine concentration and total iodine content in adults were 5.2-15.5 cm 3 , 0.28831-0.85919 mg/cm 3 and 2.35-11.69 mg, respectively. In thyroid nodule, there is no significant difference in volume, iodine concentration and total iodine content between benign and malignant nodules. All nodules with iodine concentration of less than 0.00007 mg/cm 3 were benign. No thyroid was higher in iodine concentration than the normal range although the thyroid was lower in 78.7% of patients with diffuse thyroid diseases. In all thyroids with increasing iodine concentration and total iodine content in medication course, thyroidal symptoms and signs were uncontrollable by the medication. In 43.8% of patients with long-period systemic diseases, the thyroid showed abnormality in any of the three. We concluded that quantitative in vivo measurement of thyroid iodine by CT could assist the diagnosis of thyroid diseases and decision of therapeutic methods. (author)

  4. SU-F-J-127: Multi-Institutional Evaluation of Setup, Organ Deformation, Precision Dosimetry in Total Marrow Irradiation

    International Nuclear Information System (INIS)

    Zuro, D; Hui, S

    2016-01-01

    Purpose: Totals Marrow Irradiation (TMI) is a highly focused radiation delivery to the human skeleton structure therefore requiring a high amount of precision and accuracy for a quality treatment. Not much is known on how the patient position varies across multiple treatment fractions and how that positioning impacts the dose delivery. Currently TMI is studied as an international collaboration with multiple centers around the world; however, many of these centers used different pretreatment techniques. The goal of this work is to measure the accuracy of patient positioning, its impact on dose delivery and compare the impact of each technique for multiple institutions. Methods: Using Tomotherapy pretreatment MVCTs and the planning KVCTs measurements are made of the 3D setup uncertainties of the TMI treatment. Then, using the dose and plan files of the treatment impact of patient position on dose can be measured. Measurement of organ deformation and center of mass change were done using the Velocity AI program from Varian. We are looking at four the boney targets (skull, spine, pelvis, and femur) and three key sensitive tissues (eyes, lungs, kidneys). Results: Position measurements have been made for 3 different institutions using 3 different pre-treatment techniques. Comparing the translation motion we can observe the greatest change in the Y and Z direction of patient set up. For intra-fractional motion the shoulder and clavicle represent the greatest potential for motion and therefore most likely to have a dose change. Conclusion: All centers use different techniques for their treatment and this study shows that these techniques do not produce the same pretreatment results. We hope to expand this study further. Currently we have 3 centers participating in this study with more centers joining every day.

  5. SU-F-J-127: Multi-Institutional Evaluation of Setup, Organ Deformation, Precision Dosimetry in Total Marrow Irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Zuro, D; Hui, S [University of Minnesota, Minneapolis, MN, CTMI Global Health Initiative (United States)

    2016-06-15

    Purpose: Totals Marrow Irradiation (TMI) is a highly focused radiation delivery to the human skeleton structure therefore requiring a high amount of precision and accuracy for a quality treatment. Not much is known on how the patient position varies across multiple treatment fractions and how that positioning impacts the dose delivery. Currently TMI is studied as an international collaboration with multiple centers around the world; however, many of these centers used different pretreatment techniques. The goal of this work is to measure the accuracy of patient positioning, its impact on dose delivery and compare the impact of each technique for multiple institutions. Methods: Using Tomotherapy pretreatment MVCTs and the planning KVCTs measurements are made of the 3D setup uncertainties of the TMI treatment. Then, using the dose and plan files of the treatment impact of patient position on dose can be measured. Measurement of organ deformation and center of mass change were done using the Velocity AI program from Varian. We are looking at four the boney targets (skull, spine, pelvis, and femur) and three key sensitive tissues (eyes, lungs, kidneys). Results: Position measurements have been made for 3 different institutions using 3 different pre-treatment techniques. Comparing the translation motion we can observe the greatest change in the Y and Z direction of patient set up. For intra-fractional motion the shoulder and clavicle represent the greatest potential for motion and therefore most likely to have a dose change. Conclusion: All centers use different techniques for their treatment and this study shows that these techniques do not produce the same pretreatment results. We hope to expand this study further. Currently we have 3 centers participating in this study with more centers joining every day.

  6. Measurement of the total antioxidant response in preeclampsia with a novel automated method.

    Science.gov (United States)

    Harma, Mehmet; Harma, Muge; Erel, Ozcan

    2005-01-10

    Preeclampsia is one of the most serious complications of pregnancy. Free radical damage has been implicated in the pathophysiology of this condition. In this study, we aimed to measure the antioxidant capacity in plasma samples from normotensive and preeclamptic pregnant women to evaluate their antioxidant status using a more recently developed automated measurement method. Our study group contained 42 women, 24 of whom had preeclampsia, while 18 had normotensive pregnancies. We measured the total plasma antioxidant capacity for all patients, as well as the levels of four major individual plasma antioxidant components; albumin, uric acid, ascorbic acid and bilirubin, and as a reciprocal measure, their total plasma peroxide levels. Statistically significant differences (determined using Student's t-test) were noted between the normotensive and the preeclamptic groups for their total antioxidant responses and their vitamin C levels (1.31 +/- 0.12 mmol versus 1.06 +/- 0.41 mmol Trolox eq./L; 30.2 +/- 17.83 micromol/L versus 18.1 +/- 11.37 micromol/L, respectively), which were both considerably reduced in the preeclamptic patients. In contrast, the total plasma peroxide levels were significantly elevated in this group (49.8 +/- 14.3 micromol/L versus 38.8 +/- 9.6 micromol/L). We found a decreased total antioxidant response in preeclamptic patients using a simple, rapid and reliable automated colorimetric assay, which may suitable for use in any routine clinical biochemistry laboratory, and considerably facilitates the assessment of this useful clinical parameter. We suggest that this novel method may be used as a routine test to evaluate and follow up of the levels of oxidative stress in preeclampsia.

  7. Total hemispherical emittance measured at high temperatures by the calorimetric method

    International Nuclear Information System (INIS)

    DiFilippo, F.; Mirtich, M.J.; Banks, B.A.; Stidham, C.; Kussmaul, M.

    1994-01-01

    A calorimetric vacuum emissometer (CVE) capable of measuring total hemispherical emittance of surfaces at elevated temperatures was designed, built, and tested. Several materials with a wide range of emittances were measured in the CVE between 773 to 923 K. These results were compared to values calculated from spectral emittance curves measured in a room temperature Hohlraum reflectometer and in an open-air elevated temperature emissometer. The results differed by as much as 0.2 for some materials but were in closer agreement for the more highly-emitting, diffuse-reflecting samples. The differences were attributed to temperature, atmospheric, and directional effects, and errors in the Hohlraum and emissometer measurements (± 5 percent). The probable error of the CVE measurements was typically less than 1 percent

  8. Measurement of Total Condensation on a Shrouded Cryogenic Surface using a Single Quart Crystal Microbalance

    International Nuclear Information System (INIS)

    Haid, B.J.; Malsbury, T.N.; Gibson, C.R.; Warren, C.T.

    2008-01-01

    A single quartz crystal microbalance (QCM) is cooled to 18 K to measure condensation rates inside of a retractable ''shroud'' enclosure. The shroud is of a design intended to minimize condensate on fusion targets to be fielded at the National Ignition Facility (NIF). The shroud has a double-wall construction with an inner wall that may be cooled to 75-100 K. The QCM and the shroud system were mounted in a vacuum chamber and cooled using a cryocooler. Condensation rates were measured at various vacuum levels and compositions, and with the shroud open or closed. A technique for measuring total condensate during the cooldown of the system with an accuracy of better than 1.0 x 10 -6 g/cm 2 was also demonstrated. The technique involved a separate measurement of the condensate-free crystal frequency as a function of temperature that was later applied to the measurement of interest

  9. Iodide-assisted total lead measurement and determination of different lead fractions in drinking water samples.

    Science.gov (United States)

    Zhang, Yuanyuan; Ng, Ding-Quan; Lin, Yi-Pin

    2012-07-01

    Lead and its compounds are toxic and can harm human health, especially the intelligence development in children. Accurate measurement of total lead present in drinking water is crucial in determining the extent of lead contamination and human exposure due to drinking water consumption. The USEPA method for total lead measurement (no. 200.8) is often used to analyze lead levels in drinking water. However, in the presence of high concentration of the tetravalent lead corrosion product PbO(2), the USEPA method was not able to fully recover particulate lead due to incomplete dissolution of PbO(2) particles during strong acid digestion. In this study, a new procedure that integrates membrane separation, iodometric PbO(2) measurement, strong acid digestion and ICP-MS measurement was proposed and evaluated for accurate total lead measurement and quantification of different lead fractions including soluble Pb(2+), particulate Pb(II) carbonate and PbO(2) in drinking water samples. The proposed procedure was evaluated using drinking water reconstituted with spiked Pb(2+), spiked particulate Pb(II) carbonate and in situ formed or spiked PbO(2). Recovery tests showed that the proposed procedure and the USEPA method can achieve 93-112% and 86-103% recoveries respectively for samples containing low PbO(2) concentrations (0.018-0.076 mg Pb per L). For samples containing higher concentrations of PbO(2) (0.089-1.316 mg Pb per L), the USEPA method failed to meet the recovery requirement for total lead (85-115%) while the proposed method can achieve satisfactory recoveries (91-111%) and differentiate the soluble Pb(2+), particulate Pb(II) carbonate and PbO(2).

  10. METHODS FOR THE DETERMINATION OF TOTAL ORGANIC CARBON (TOC) IN SOILS AND SEDIMENTS

    Science.gov (United States)

    Organic matter in soils and sediments is widely distributed over the earth's surface occurring in almost all terrestrial and aquatic environments (Schnitzer, 1978). Soils and sediments contain a large variety of organic materials ranging from simple sugars and carbohydrates to th...

  11. Building-Related Symptoms among Office Employees Associated with Indoor Carbon Dioxide and Total Volatile Organic Compounds

    Directory of Open Access Journals (Sweden)

    Chung-Yen Lu

    2015-05-01

    Full Text Available This study investigated whether sick building syndrome (SBS complaints among office workers were associated with the indoor air quality. With informed consent, 417 employees in 87 office rooms of eight high-rise buildings completed a self-reported questionnaire for symptoms experienced at work during the past month. Carbon dioxide (CO2, temperature, humidity and total volatile organic compounds (TVOCs in each office were simultaneously measured for eight office hours using portable monitors. Time-averaged workday difference between the indoor and the outdoor CO2 concentrations (dCO2 was calculated as a surrogate measure of ventilation efficiency for each office unit. The prevalence rates of SBS were 22.5% for eye syndrome, 15.3% for upper respiratory and 25.4% for non-specific syndromes. Tiredness (20.9%, difficulty in concentrating (14.6%, eye dryness (18.7% were also common complaints. The generalized estimating equations multivariate logistic regression analyses showed that adjusted odds ratios (aORs and 95% confidence interval (CI per 100 ppm increase in dCO2 were significantly associated with dry throat (1.10, 95% CI = (1.00–1.22, tiredness (1.16, 95% CI = (1.04–1.29 and dizziness (1.22, 95% CI = (1.08–1.37. The ORs for per 100 ppb increases in TVOCs were also associated with upper respiratory symptoms (1.06, 95% CI = (1.04–1.07, dry throat (1.06, 95% CI = (1.03–1.09 and irritability (1.02, 95% CI = (1.01–1.04. In conclusion, the association between some SBS symptoms and the exposure to CO2 and total VOCs are moderate but may be independently significant.

  12. Total cross section measurement of radioactive isotopes with a thin beam neutron spectrometer

    International Nuclear Information System (INIS)

    Razbudej, V.F.; Vertebnyj, V.P.; Padun, G.S.; Muravitskij, A.V.

    1975-01-01

    The method for measuring the neutron total cross sections of radioactive isotopes by a time-of-flight spectrometer with a narrow (0.17 mm in diameter) beam of thermal neutrons is described. The distinguishing feature of this method is the use of capillary samples with a small amount of substance (0.05-1.0 mg). The energy range is 0.01-0.3 eV. The total cross sections of irradiated samples of sub(153)Eu and sub(151)Eu are measured. From them are obtained the cross sections of sub(152)Eu (Tsub(1/2)=12.4 g) and of sub(154)E (Tsub(1/2)=8.6 yr); they equal 11400+-1400 and 1530+-190 barn at E=0.0253 eV. The cross section of the sub(152)Eu absorption for the thermal spectrum (T=333 K) is determined by the activation method; it is 8900+-1200 barn

  13. Total pion cross section measurements. Annual progress report, 1 January 1977--31 December 1978

    International Nuclear Information System (INIS)

    Jakobson, M.J.; Jeppesen, R.H.

    1978-01-01

    The pion-nucleus total cross section runs were completed. The principal effort for the past year has been devoted to data analysis. The experiment was primarily designed to provide an accurate measurement of total cross section differences for pairs of isotopes. Data were published on neutron radii of calcium isotopes and on pion cross section measurements for aligned holmium. The π+- data to be published include targets and energies for 4 He, 23 → 90 MeV; 12 C, 13 C, 23 → 240 MeV; 6 Li, 7 Li, 9 Be, 10 B, 11 B, 43 → 215 MeV; 16 O, 18 O, 40 Ca, 44 Ca, 48 Ca, 43 → 240 MeV; 45 Sc, 51 V, Al, Cu, Sn, Ho, Pb, 60 → 215 MeV

  14. Measurement of total body calcium in osteoporotic patients treated with salmon calcitonin

    International Nuclear Information System (INIS)

    Zanzi, I.; Thompson, K.; Cohn, S.H.

    1981-01-01

    In the past, the evaluation of therapies for osteoporosis has been limited by the lack of a suitable quantitative end point. The introduction of the technique of in vivo total body neutron activation analysis (TBNAA) has made possible the precise and accurate measurement of total body calcium (TBCa). Since almost 99 percent of TBCa is in the skeleton, TBNAA gives a direct measurement of skeletal mass. Thus, changes in skeletal mass serve as an objective criterion in the evaluation of the efficacy of the therapy in osteoporosis. Studies performed at Brookhaven National Laboratory and elsewhere have reported the use of calcitonin (CT) in the treatment of primary osteoporosis and related conditions in a limited number of patients. The physiological effects of CT as an inhibitor of bone resorption has been the rationale of its use. The results of a randomized, controlled, 2 year therapeutical trial of CT in a group of postmenopausal osteoporotic women are presented in this report

  15. Measurements of effective total macroscopic cross sections and effective energy of continuum beam

    Energy Technology Data Exchange (ETDEWEB)

    Kobayashi, Hisao [Rikkyo Univ., Yokosuka, Kanagawa (Japan). Inst. for Atomic Energy

    1998-03-01

    Two practically useful quantities are introduced in this study to characterize a continuum neutron beam and to describe transmission phenomena of the beam in field of quantitative neutron radiography: an effective energy instead of a peak energy or a mean energy of the spectrum and an effective total macroscopic (ETM) cross section instead of a total macroscopic (TM) cross section defined at the monochromatic energy. The effective energy was evaluated by means of energy dependence of ETM cross section. To realize the method a beam quality indicator (BQI) has been proposed recently. Several effective energies were measured for non-filtered, filtered neutron beams, and outputs of neutron guide tubes in world by the BQI. A thermal neutron beam and three beams modulated by Pb filters with different thicknesses are studied to measure ETM cross sections for various materials and summarized in a table. Validity of the effective energy determined by the BQI is discussed relating with ETM cross sections of materials. (author)

  16. Changes in body chemical composition with age measured by total-body neutron activation

    International Nuclear Information System (INIS)

    Cohn, S.H.; Vaswani, A.; Zanzi, I.; Aloia, J.F.; Roginsky, M.S.; Ellis, K.J.

    1976-01-01

    Total-body levels of calcium and phosphorus (reflecting skeletal mass) and total-body levels of potassium (reflecting muscle mass) were measured by neutron activation analysis in 39 men and 40 women ages 30 to 90 yr. In order to intercompare the total body calcium (TBCa) values in a heterogeneous population, such as this, it was necessary to normalize the data for skeletal size. The normalization consisted of dividing the absolute calcium level by the predicted calcium level for each individual matched to a set of critical parameters. The parameter used in the computation of normal values were age, sex, muscle mass, i.e., total body potassium (TBK) and height. For the calcium data of the women, it was necessary to add an age correction factor after the age of 55 yr. The calcium ratio (mean ratio of the predicted to measured TBCa) in men was 1.000 +- 7.8 percent and in women 0.996 +- 7.1 percent. The TBCa of normal males and females can thus be predicted to +-13 percent (at the 90 percent confidence level). An exception to this was found in males (70 to 90 yr) who exhibited a mean calcium ratio greater than 1.13

  17. Comprehensive measurement of total nondigestible carbohydrates in foods by enzymatic-gravimetric method and liquid chromatography.

    Science.gov (United States)

    Nishibata, Toyohide; Tashiro, Kouichi; Kanahori, Sumiko; Hashizume, Chieko; Kitagawa, Machiko; Okuma, Kazuhiro; Gordon, Dennis T

    2009-09-09

    Total nondigestible carbohydrate (NDC) in foods was determined by combining, not modifications, AOAC Official Methods 991.43, 2001.03, and 2002.02. Total NDC included insoluble dietary fiber (IDF) + high-molecular-weight soluble dietary fiber (HMWSDF), nondigestible oligosaccharides (NDO) not precipitated in ethanol solution, and resistant starch (RS). Eight sources of NDC (cellulose, wheat bran, gum arabic, resistant maltodextrin, polydextrose, fructooligosaccharide, galactooligosaccharides, and RS) were incorporated in different combinations into standard formula bread samples. All of the NDC sources and bread samples were analyzed for their (1) IDF + HMWSDF content with corrections for residual RS amount using AOAC Official Method 991.43, (2) NDO by liquid chromatography (LC) in AOAC Official Method 2001.03, and (3) RS by AOAC Official Method 2002.02. The correlation coefficient (R(2)) comparing calculated amounts versus measured amounts of total NDC in 11 bread samples was 0.92. Analysis of commercial food samples was also well matched with the DF + NDO value on their nutritional label. Consequently, we confirmed a single measurement of LC can determine all NDO in foods, and total NDC in foods can be determined by unifying existing AOAC Official Methods.

  18. Argon intermolecular potential from a measurement of the total scattering cross-section

    International Nuclear Information System (INIS)

    Wong, Y.W.

    1975-01-01

    An inversion method to obtain accurate intermolecular potentials from experimental total cross section measurements is presented. This method is based on the high energy Massey--Smith approximation. The attractive portion of the potential is represented by a multi-parameter spline function and the repulsive part by a Morse function. The best fit potential is obtained by a least squares minimization based on comparison of experimental cross sections with those obtained by a Fourier transform of the reduced Massey--Smith phase shift curve. An experimental method was developed to obtain the total cross sections needed for the above inversion procedure. In this technique, integral cross sections are measured at various resolutions and the total cross section is obtained by extrapolating to infinite resolution. Experimental results obtained for the Ar--Ar system are in excellent agreement with total cross sections calculated using the Barker-Fisher-Watts potential. Inversion of the data to obtain a potential distinguishable from the BFW-potential requires an extension of the method based on the Massey--Smith approximation to permit use of JWKB phase shifts and was not attempted

  19. Plutonium Finishing Plant (PFP) Generalized Geometry Holdup Calculations and Total Measurement Uncertainty

    International Nuclear Information System (INIS)

    Keele, B.D.

    2005-01-01

    A collimated portable gamma-ray detector will be used to quantify the plutonium content of items that can be approximated as a point, line, or area geometry with respect to the detector. These items can include ducts, piping, glove boxes, isolated equipment inside of gloveboxes, and HEPA filters. The Generalized Geometry Holdup (GGH) model is used for the reduction of counting data. This document specifies the calculations to reduce counting data into contained plutonium and the associated total measurement uncertainty.

  20. Objectively Measured Total and Occupational Sedentary Time in Three Work Settings

    OpenAIRE

    van Dommelen, Paula; Coffeng, Jennifer K.; van der Ploeg, Hidde P.; van der Beek, Allard J.; Boot, C?cile R. L.; Hendriksen, Ingrid J. M.

    2016-01-01

    Background. Sedentary behaviour increases the risk for morbidity. Our primary aim is to determine the proportion and factors associated with objectively measured total and occupational sedentary time in three work settings. Secondary aim is to study the proportion of physical activity and prolonged sedentary bouts. Methods. Data were obtained using ActiGraph accelerometers from employees of: 1) a financial service provider (n = 49 men, 31 women), 2) two research institutes (n = 30 men, 57 wom...

  1. Measurement of total reaction cross sections of exotic neutron rich nuclei

    International Nuclear Information System (INIS)

    Mittig, W.; Chouvel, J.M.; Wen Long, Z.

    1987-01-01

    Total reaction cross-sections of neutron rich nuclei from C to Mg in a thick Si-target have been measured using the detection of the associated γ-rays in a 4Π-geometry. This cross-section strongly increases with neutron excess, indicating an increase of as much as 15% of the reduced strong absorption radius with respect to stable nuclei

  2. Total luminous flux measurement for flexible surface sources with an integrating sphere photometer

    International Nuclear Information System (INIS)

    Yu, Hsueh-Ling; Liu, Wen-Chun

    2014-01-01

    Applying an integrating sphere photometer for total luminous flux measurement is a widely used method. However, the measurement accuracy depends on the spatial uniformity of the integrating sphere, especially when the test sample has a different light distribution from that of the standard source. Therefore, spatial correction is needed to eliminate the effect caused by non-uniformity. To reduce the inconvenience of spatial correction but retain the measurement accuracy, a new type of working standard is designed for flexible and curved surface sources. Applying this new type standard source, the measurement deviation due to different orientations is reduced by an order of magnitude compared with using a naked incandescent lamp as the standard source. (paper)

  3. Parametrization consequences of constraining soil organic matter models by total carbon and radiocarbon using long-term field data

    Science.gov (United States)

    Menichetti, Lorenzo; Kätterer, Thomas; Leifeld, Jens

    2016-05-01

    Soil organic carbon (SOC) dynamics result from different interacting processes and controls on spatial scales from sub-aggregate to pedon to the whole ecosystem. These complex dynamics are translated into models as abundant degrees of freedom. This high number of not directly measurable variables and, on the other hand, very limited data at disposal result in equifinality and parameter uncertainty. Carbon radioisotope measurements are a proxy for SOC age both at annual to decadal (bomb peak based) and centennial to millennial timescales (radio decay based), and thus can be used in addition to total organic C for constraining SOC models. By considering this additional information, uncertainties in model structure and parameters may be reduced. To test this hypothesis we studied SOC dynamics and their defining kinetic parameters in the Zürich Organic Fertilization Experiment (ZOFE) experiment, a > 60-year-old controlled cropland experiment in Switzerland, by utilizing SOC and SO14C time series. To represent different processes we applied five model structures, all stemming from a simple mother model (Introductory Carbon Balance Model - ICBM): (I) two decomposing pools, (II) an inert pool added, (III) three decomposing pools, (IV) two decomposing pools with a substrate control feedback on decomposition, (V) as IV but with also an inert pool. These structures were extended to explicitly represent total SOC and 14C pools. The use of different model structures allowed us to explore model structural uncertainty and the impact of 14C on kinetic parameters. We considered parameter uncertainty by calibrating in a formal Bayesian framework. By varying the relative importance of total SOC and SO14C data in the calibration, we could quantify the effect of the information from these two data streams on estimated model parameters. The weighing of the two data streams was crucial for determining model outcomes, and we suggest including it in future modeling efforts whenever SO14C

  4. Measurement of total-body cobalt-57 vitamin B12 absorption with a gamma camera

    International Nuclear Information System (INIS)

    Cardarelli, J.A.; Slingerland, D.W.; Burrows, B.A.; Miller, A.

    1985-01-01

    Previously described techniques for the measurement of the absorption of [ 57 Co]vitamin B 12 by total-body counting have required an iron room equipped with scanning or multiple detectors. The present study uses simplifying modifications which make the technique more available and include the use of static geometry, the measurement of body thickness to correct for attenuation, a simple formula to convert the capsule-in-air count to a 100% absorption count, and finally the use of an adequately shielded gamma camera obviating the need of an iron room

  5. Measurement of total lung capacity : a comparison of spiral CT and spirometry

    International Nuclear Information System (INIS)

    Chung, Kyung Il; Park, Kyung Ju; Lee, Eh Hyung; Yune, Heun Young; Suh, Jung Ho; Choe, Kyu Ok; Lim, Tae Hwan; Chung, In Hyuk

    1996-01-01

    To determine the potential of spiral CT as a functional imaging modality of the lung aside from its proven value in morphological depiction. Spiral CT scan was performed in ten normal female and nine normal male adults (mean age: 39, height: 163 cm, weight: 62 kg ) after single full breath-holding. Three dimensional lung images were reconstructed(minimal threshold value: -1,000HU, maximal threshold values: -150, 250, -350, -450 HU) to obtain total lung volume(TLV) on a histogram. Total lung volume measured by spiral CT was compared with TLV obtained by spirometry. Mean TLV measured by spirometry was 5.62L and TLV measured by CT at maximal threshold values of -150, -250, -350, and -450 HU was 5.53, 5.33, 5.15, and 4.98L, respectively. Mean absolute differences between the modalities of 0.17L(3%), 0.32L(5.6%), 0.48L(8.5%), 0.65L(11.5%) were statistically significant(p<0.001). Linear regression coefficients between the modalities were 0.99, 0.97, 095, and 0.94 and no statistically significant differences in accuracy of threshold levels in the estimation of lung volume(r=0.99, standard error=0.034L in all) were seen. TLV measured by spiral CT closely approximated that measured by spirometry. Spiral CT may be useful as a means of evaluating lung function

  6. Discriminative ability of total body bone-mineral measured by dual photon absorptiometry

    International Nuclear Information System (INIS)

    Gotfredsen, A.; Poedenphant, J.; Nilas, L.; Christiansen, C.

    1989-01-01

    We investigated the descriminative ability of total body bone-mineral expressed as the total body bone-density (TBBD) measured by dual photon absorptiometry (DPA) in 79 healthy premenopausal women, 27 healthy postmenopausal women, and 120 female osteoporotic fracture patients presenting with either Colles' fracture, vertebral fracture or femoral neck-fracture. TBBD was compared to the bone-mineral density of the lumbar spine (BMD spine ) also measured by DPA, and to the bone-mineral content of the forearms (BMC forearm ) measured by single photon absorptiometry (SPA). TBBD, BMD spine and BMC forearm showed that all the fracture patient groups had significantly reduced bone-mass. Using receiver operating characteristic (ROC) analysis, we found that TBBD had a tendency towards better discriminative ability than BMD spine or BMC forearm with regard to the discrimination between healthy premenopausal women and the three types of osteoporotic fractures. BMC forearm had an intermediate position, whereas BMD spine had the smallest discriminative ability. TBBD also discriminated better between healthy postmenopausal women and hip-fracture patients than BMD spine or BMC forearm , whereas there was no significant difference between the three methods regarding the discrimination between the healthy postmenopausal women and the Colles' and spinal fracture patients. We conclude that the TBBD measurement by DPA has a discriminative potential which is better than the local spine or forearm measurements. (author)

  7. A new method of body habitus correction for total body potassium measurements

    International Nuclear Information System (INIS)

    O'Hehir, S; Green, S; Beddoe, A H

    2006-01-01

    This paper describes an accurate and time-efficient method for the determination of total body potassium via a combination of measurements in the Birmingham whole body counter and the use of the Monte Carlo n-particle (MCNP) simulation code. In developing this method, MCNP has also been used to derive values for some components of the total measurement uncertainty which are difficult to quantify experimentally. A method is proposed for MCNP-assessed body habitus corrections based on a simple generic anthropomorphic model, scaled for individual height and weight. The use of this model increases patient comfort by reducing the need for comprehensive anthropomorphic measurements. The analysis shows that the total uncertainty in potassium weight determination by this whole body counting methodology for water-filled phantoms with a known amount of potassium is 2.7% (SD). The uncertainty in the method of body habitus correction (applicable also to phantom-based methods) is 1.5% (SD). It is concluded that this new strategy provides a sufficiently accurate model for routine clinical use

  8. Hydrogen production by the iodine-sulphur thermochemical cycle. Total and partial pressure measurements

    International Nuclear Information System (INIS)

    D Doizi; V Dauvois; J L Roujou; V Delanne; P Fauvet; B Larousse; O Hercher; P Carles; C Moulin

    2006-01-01

    The iodine sulphur thermochemical cycle appears to be one of the most promising candidate for the massive production of hydrogen using nuclear energy. The key step in this cycle is the HI distillation section which must be optimized to get a good efficiency of the overall cycle. The concept of reactive versus extractive distillation of HI has been proposed because of its potentiality. The design and the optimization of the reactive distillation column requires the knowledge of the liquid vapour equilibrium over the ternary HI-I 2 -H 2 O mixtures up to 300 C and 100 bars. A general methodology based on three experimental devices imposed by the very corrosive and concentrated media will be described: 1) I1 for the total pressure measurement versus different ternary compositions. 2) I2 for the partial and total pressure measurements around 130 C and 2 bars to validate the choice of the analytical optical 'online' techniques we have proposed. 3) I3 for the partial and total pressures measurements in the process domain. The results obtained on pure samples, binary mixtures HI-H 2 O and ternary mixtures using an experimental design analysis in the experimental device I2 will be discussed. (authors)

  9. A new method of body habitus correction for total body potassium measurements

    Energy Technology Data Exchange (ETDEWEB)

    O' Hehir, S [University Hospital Birmingham Foundation NHS Trust, Birmingham (United Kingdom); Green, S [University Hospital Birmingham Foundation NHS Trust, Birmingham (United Kingdom); Beddoe, A H [University Hospital Birmingham Foundation NHS Trust, Birmingham (United Kingdom)

    2006-09-07

    This paper describes an accurate and time-efficient method for the determination of total body potassium via a combination of measurements in the Birmingham whole body counter and the use of the Monte Carlo n-particle (MCNP) simulation code. In developing this method, MCNP has also been used to derive values for some components of the total measurement uncertainty which are difficult to quantify experimentally. A method is proposed for MCNP-assessed body habitus corrections based on a simple generic anthropomorphic model, scaled for individual height and weight. The use of this model increases patient comfort by reducing the need for comprehensive anthropomorphic measurements. The analysis shows that the total uncertainty in potassium weight determination by this whole body counting methodology for water-filled phantoms with a known amount of potassium is 2.7% (SD). The uncertainty in the method of body habitus correction (applicable also to phantom-based methods) is 1.5% (SD). It is concluded that this new strategy provides a sufficiently accurate model for routine clinical use.

  10. Warming and organic matter sources impact the proportion of dissolved to total activities in marine extracellular enzymatic rates

    KAUST Repository

    Baltar, Federico

    2017-04-19

    Extracellular enzymatic activities (EEAs) are the rate-limiting step in the degradation of organic matter. Extracellular enzymes can be found associated to cells or dissolved in the surrounding water. The proportion of cell-free EEA constitutes in many marine environments more than half of the total activity. This high proportion causes an uncoupling between hydrolysis rates and the actual bacterial activity. However, we do not know what factors control the proportion of dissolved relative to total EEA, nor how this may change in the future ocean. To resolve this, we performed laboratory experiments with water from the Great Barrier Reef (Australia) to study the effects of temperature and dissolved organic matter sources on EEA and the proportion of dissolved EEA. We found that warming increases the rates of organic matter hydrolysis and reduces the proportion of dissolved relative to total EEA. This suggests a potential increase of the coupling between organic matter hydrolysis and heterotrophic activities with increasing ocean temperatures, although strongly dependent on the organic matter substrates available. Our study suggests that local differences in the organic matter composition in tropical coastal ecosystems will strongly affect the proportion of dissolved EEA in response to ocean warming.

  11. INVESTIGATION OF THE TOTAL ORGANIC HALOGEN ANALYTICAL METHOD AT THE WASTE SAMPLING CHARACTERIZATION FACILITY (WSCF)

    International Nuclear Information System (INIS)

    DOUGLAS JG; MEZNARICH HD, PHD; OLSEN JR; ROSS GA; STAUFFER M

    2008-01-01

    Total organic halogen (TOX) is used as a parameter to screen groundwater samples at the Hanford Site. Trending is done for each groundwater well, and changes in TOX and other screening parameters can lead to costly changes in the monitoring protocol. The Waste Sampling and Characterization Facility (WSCF) analyzes groundwater samples for TOX using the United States Environmental Protection Agency (EPA) SW-846 method 9020B (EPA 1996a). Samples from the Soil and Groundwater Remediation Project (S and GRP) are submitted to the WSCF for analysis without information regarding the source of the sample; each sample is in essence a 'blind' sample to the laboratory. Feedback from the S and GRP indicated that some of the WSCF-generated TOX data from groundwater wells had a number of outlier values based on the historical trends (Anastos 2008a). Additionally, analysts at WSCF observed inconsistent TOX results among field sample replicates. Therefore, the WSCF lab performed an investigation of the TOX analysis to determine the cause of the outlier data points. Two causes were found that contributed to generating out-of-trend TOX data: (1) The presence of inorganic chloride in the groundwater samples: at inorganic chloride concentrations greater than about 10 parts per million (ppm), apparent TOX values increase with increasing chloride concentration. A parallel observation is the increase in apparent breakthrough of TOX from the first to the second activated-carbon adsorption tubes with increasing inorganic chloride concentration. (2) During the sample preparation step, excessive purging of the adsorption tubes with oxygen pressurization gas after sample loading may cause channeling in the activated-carbon bed. This channeling leads to poor removal of inorganic chloride during the subsequent wash step with aqueous potassium nitrate. The presence of this residual inorganic chloride then produces erroneously high TOX values. Changes in sample preparation were studied to more

  12. Single-slice epicardial fat area measurement. Do we need to measure the total epicardial fat volume?

    International Nuclear Information System (INIS)

    Oyama, Noriko; Goto, Daisuke; Ito, Yoichi M.

    2011-01-01

    The aim of this study was to assess a method for measuring epicardial fat volume (EFV) by means of a single-slice area measurement. We investigated the relation between a single-slice fat area measurement and total EFV. A series of 72 consecutive patients (ages 65±11 years; 36 men) who had undergone cardiac computed tomography (CT) on a 64-slice multidetector scanner with prospective electrocardiographic triggering were retrospectively reviewed. Pixels in the pericardium with a density range from -230 to -30 Hounsfield units were considered fat, giving the per-slice epicardial fat area (EFA). The EFV was estimated by the summation of EFAs multiplied by the slice thickness. We investigated the relation between total EFV and each EFA. EFAs measured at several anatomical landmarks - right pulmonary artery, origins of the left main coronary artery, right coronary artery, coronary sinus - all correlated with the EFV (r=0.77-0.92). The EFA at the LMCA level was highly reproducible and showed an excellent correlation with the EFV (r=0.92). The EFA is significantly correlated with the EFV. The EFA is a simple, quick method for representing the time-consuming EFV, which has been used as a predictive indicator of cardiovascular diseases. (author)

  13. Measuring the Complexity of Self-Organizing Traffic Lights

    Directory of Open Access Journals (Sweden)

    Darío Zubillaga

    2014-04-01

    Full Text Available We apply measures of complexity, emergence, and self-organization to an urban traffic model for comparing a traditional traffic-light coordination method with a self-organizing method in two scenarios: cyclic boundaries and non-orientable boundaries. We show that the measures are useful to identify and characterize different dynamical phases. It becomes clear that different operation regimes are required for different traffic demands. Thus, not only is traffic a non-stationary problem, requiring controllers to adapt constantly; controllers must also change drastically the complexity of their behavior depending on the demand. Based on our measures and extending Ashby’s law of requisite variety, we can say that the self-organizing method achieves an adaptability level comparable to that of a living system.

  14. Developing SyrinOX total antioxidant capacity assay for measuring antioxidants in humans.

    Science.gov (United States)

    Prasetyo, Endry N; Knes, Otto; Nyanhongo, Gibson S; Guebitz, Georg M

    2013-02-01

    Accurate monitoring of the antioxidant status or of oxidative stress in patients is still a big challenge in clinical laboratories. This study investigates the possibility of applying a newly developed total antioxidant capacity assay method based on laccase or peroxidase oxidized syringaldazine [Tetramethoxy azobismethylene quinone (TMAMQ)] which is referred to here as SyrinOX, as a diagnostic tool for monitoring both oxidative stress and antioxidant status in patients. Attempts to adapt the Randox total antioxidant procedure [simultaneous incubation of the radical generating system (metmyoglobin and H(2) O(2) ) and antioxidant sample] for SyrinOX were abandoned after it was discovered that the H(2) O(2) reacted with enzymatically generated TMAMQ and ABTS radicals at a rate of 6.4 × 10(-2) /μM/s and 5.7 × 10(-3) /μM/s respectively. Thus this study for the first time demonstrates the negative effects of H(2) O(2) in the Randox system. This leads to erroneous results because the total antioxidant values obtained are the sum of radicals reduced by antioxidants plus those reacting with the radical generating system. Therefore they should be avoided not only for this particular method but also when using other similar methods. Consequently, SyrinOX is best applied using a three-step approach involving, production of TMAMQ, recovery and purification (free from enzyme and other impurities) and then using TMAMQ for measuring the total antioxidant capacity of samples. Using this approach, the reaction conditions for application of SyrinOX when measuring the total antioxidant capacity of plasma sample were determined to be 50% (v/v) ethanol/50 mM sodium succinate buffer pH 5.5, between 20 and 25 °C for at least 1 h. © 2012 The Authors. International Journal of Experimental Pathology © 2012 International Journal of Experimental Pathology.

  15. MEASURING PERFORMANCE IN ORGANIZATIONS FROM MULTI-DIMENSIONAL PERSPECTIVE

    Directory of Open Access Journals (Sweden)

    ȘTEFĂNESCU CRISTIAN

    2017-08-01

    Full Text Available In turbulent financial and economic present conditions a major challenge for the general management of organizations and in particular for the strategic human resources management is to establish a clear, coherent and consistent framework in terms of measuring organizational performance and economic efficiency. This paper aims to conduct an exploratory research of literature concerning measuring organizational performance. Based on the results of research the paper proposes a multi-dimensional model for measuring organizational performance providing a mechanism that will allow quantification of performance based on selected criteria. The model will attempt to eliminate inconsistencies and incongruities of organizational effectiveness models developed by specialists from organization theory area, performance measurement models developed by specialists from accounting management area and models of measuring the efficiency and effectiveness developed by specialists from strategic management and entrepreneurship areas.

  16. Calculation of midplane dose for total body irradiation from entrance and exit dose MOSFET measurements.

    Science.gov (United States)

    Satory, P R

    2012-03-01

    This work is the development of a MOSFET based surface in vivo dosimetry system for total body irradiation patients treated with bilateral extended SSD beams using PMMA missing tissue compensators adjacent to the patient. An empirical formula to calculate midplane dose from MOSFET measured entrance and exit doses has been derived. The dependency of surface dose on the air-gap between the spoiler and the surface was investigated by suspending a spoiler above a water phantom, and taking percentage depth dose measurements (PDD). Exit and entrances doses were measured with MOSFETs in conjunction with midplane doses measured with an ion chamber. The entrance and exit doses were combined using an exponential attenuation formula to give an estimate of midplane dose and were compared to the midplane ion chamber measurement for a range of phantom thicknesses. Having a maximum PDD at the surface simplifies the prediction of midplane dose, which is achieved by ensuring that the air gap between the compensator and the surface is less than 10 cm. The comparison of estimated midplane dose and measured midplane dose showed no dependence on phantom thickness and an average correction factor of 0.88 was found. If the missing tissue compensators are kept within 10 cm of the patient then MOSFET measurements of entrance and exit dose can predict the midplane dose for the patient.

  17. Measurement of neutron total cross-sections for {sup nat}Dy at Pohang Neutron Facility

    Energy Technology Data Exchange (ETDEWEB)

    Shin, S. G.; Kye, Y. U.; Shvetsov, Valery; Cho, M. H. [POSTECH, Pohang (Korea, Republic of); Namkung, W.; Cho, M. H. [Pohang Accelerator Laboratory, Pohang (Korea, Republic of); Kim, G. N. [Kyungpook National Univ., Daegu (Korea, Republic of); Lee, M. W. [Dongnam Inst. of radiological and Medical Science, Busan (Korea, Republic of)

    2013-05-15

    There are few measurements for Dy below 100 eV. Moreover, there exist discrepancies among the measurements. In the present work, the total neutron cross-sections for {sup nat}Dy were measured by using the time-of-flight (TOF) method at the Pohang Neutron Facility (PNF). The PNF consists of an electron linac, a water-cooled Ta target, and an 11-m-long TOF path. The characteristics of PNF are described elsewhere. We also briefly discuss the future plan to verify our experimental result. We have measured the total neutron cross-sections of {sup nat}Dy in the neutron energy region from 0.1 eV to 100 eV with the TOF method at the Po hang Neutron Facility. The present result is in good agreement with the previous data and the evaluated data in ENDF/B-VI. We would like to get resonance parameters by using SAMMY or REFIT codes.

  18. A comparison between two methods of measuring total fat in the Iranian soldiers

    Directory of Open Access Journals (Sweden)

    J. Rahmani

    2017-04-01

    Full Text Available Background: Constant checkup and control of body fat mass is an important parameter for the health and efficiency of individuals in any society. This parameter is especially crucial in army soldiers since physical fitness is a key role in reaching high physical performance, health, and survival in war. Objective: This study was designed to compare two methods of measuring fat, the method of circumference-based military equations (CBEs to estimate body fat mass compared to the method of skinfold thickness-based equation (SBE in Iranian soldiers. Methods: This cross-sectional study was conducted on 246 Iranian soldiers were recruited in Tehran (2016. Height, waist, and neck circumference were measured and the total body fat mass was calculated using CBEs. Then, the results of using Pierson’s correlation and Bland-Altman methods were compared with Jackson and Pollock’s skinfold thickness measurement. Findings: The total body fat mass of the soldiers using CBEs was 18.94±6.30% and using Jakson and Pollock’s skinfold thickness formula was 17.43±4.45%. The correlation between the two methods was r=0.984 and SEE was 1.1% (P<0.001. Conclusion: The more body fat makes the error waist circumference greater. The error is so much that don’t use this method to measure fat.

  19. Development and calibration of an accurate 6-degree-of-freedom measurement system with total station

    International Nuclear Information System (INIS)

    Gao, Yang; Lin, Jiarui; Yang, Linghui; Zhu, Jigui

    2016-01-01

    To meet the demand of high-accuracy, long-range and portable use in large-scale metrology for pose measurement, this paper develops a 6-degree-of-freedom (6-DOF) measurement system based on total station by utilizing its advantages of long range and relative high accuracy. The cooperative target sensor, which is mainly composed of a pinhole prism, an industrial lens, a camera and a biaxial inclinometer, is designed to be portable in use. Subsequently, a precise mathematical model is proposed from the input variables observed by total station, imaging system and inclinometer to the output six pose variables. The model must be calibrated in two levels: the intrinsic parameters of imaging system, and the rotation matrix between coordinate systems of the camera and the inclinometer. Then corresponding approaches are presented. For the first level, we introduce a precise two-axis rotary table as a calibration reference. And for the second level, we propose a calibration method by varying the pose of a rigid body with the target sensor and a reference prism on it. Finally, through simulations and various experiments, the feasibilities of the measurement model and calibration methods are validated, and the measurement accuracy of the system is evaluated. (paper)

  20. Superresolution confocal technology for displacement measurements based on total internal reflection.

    Science.gov (United States)

    Kuang, Cuifang; Ali, M Yakut; Hao, Xiang; Wang, Tingting; Liu, Xu

    2010-10-01

    In order to achieve a higher axial resolution for displacement measurement, a novel method is proposed based on total internal reflection filter and confocal microscope principle. A theoretical analysis of the basic measurement principles is presented. The analysis reveals that the proposed confocal detection scheme is effective in enhancing the resolution of nonlinearity of the reflectance curve greatly. In addition, a simple prototype system has been developed based on the theoretical analysis and a series of experiments have been performed under laboratory conditions to verify the system feasibility, accuracy, and stability. The experimental results demonstrate that the axial resolution in displacement measurements is better than 1 nm in a range of 200 nm which is threefold better than that can be achieved using the plane reflector.

  1. Superresolution confocal technology for displacement measurements based on total internal reflection

    International Nuclear Information System (INIS)

    Kuang Cuifang; Hao Xiang; Wang Tingting; Liu Xu; Ali, M. Yakut

    2010-01-01

    In order to achieve a higher axial resolution for displacement measurement, a novel method is proposed based on total internal reflection filter and confocal microscope principle. A theoretical analysis of the basic measurement principles is presented. The analysis reveals that the proposed confocal detection scheme is effective in enhancing the resolution of nonlinearity of the reflectance curve greatly. In addition, a simple prototype system has been developed based on the theoretical analysis and a series of experiments have been performed under laboratory conditions to verify the system feasibility, accuracy, and stability. The experimental results demonstrate that the axial resolution in displacement measurements is better than 1 nm in a range of 200 nm which is threefold better than that can be achieved using the plane reflector.

  2. Measurement of the polarized neutron---polarized 3He total cross section

    International Nuclear Information System (INIS)

    Keith, C.D.; Gould, C.R.; Haase, D.G.; Seely, M.L.; Huffman, P.R.; Roberson, N.R.; Tornow, W.; Wilburn, W.S.

    1995-01-01

    The first measurements of polarized neutron--polarized 3 He scattering in the few MeV energy region are reported. The total cross section difference Δσ T for transversely polarized target and beam has been measured for neutron energies between 1.9 and 7.5 MeV. Comparison is made to predictions of Δσ T using various descriptions of the 4 He continuum. A brute-force polarized target of solid 3 He has been developed for these measurements. The target is 4.3x10 22 atoms/cm 2 thick and is polarized to 38% at 7 Telsa and 12 mK. copyright 1995 American Institute of Physics

  3. Hospital-Based Acute Care After Total Hip and Knee Arthroplasty: Implications for Quality Measurement.

    Science.gov (United States)

    Trimba, Roman; Laughlin, Richard T; Krishnamurthy, Anil; Ross, Joseph S; Fox, Justin P

    2016-03-01

    Although hospital readmissions are being adopted as a quality measure after total hip or knee arthroplasty, they may fail accurately capture the patient's postdischarge experience. We studied 272,853 discharges from 517 hospitals to determine hospital emergency department (ED) visit and readmission rates. The hospital-level, 30-day, risk-standardized ED visit (median = 5.6% [2.4%-13.7%]) and hospital readmission (5.0% [2.6%-9.2%]) rates were similar and varied widely. A hospital's risk-standardized ED visit rate did not correlate with its readmission rate (r = -0.03, P = .50). If ED visits were included in a broader "readmission" measure, 246 (47.6%) hospitals would change perceived performance groups. Including ED visits in a broader, hospital-based, acute care measure may be warranted to better describe postdischarge health care utilization. Copyright © 2016 Elsevier Inc. All rights reserved.

  4. Six years of total ozone column measurements from SCIAMACHY nadir observations

    Science.gov (United States)

    Lerot, C.; van Roozendael, M.; van Geffen, J.; van Gent, J.; Fayt, C.; Spurr, R.; Lichtenberg, G.; von Bargen, A.

    2009-04-01

    Total O3 columns have been retrieved from six years of SCIAMACHY nadir UV radiance measurements using SDOAS, an adaptation of the GDOAS algorithm previously developed at BIRA-IASB for the GOME instrument. GDOAS and SDOAS have been implemented by the German Aerospace Center (DLR) in the version 4 of the GOME Data Processor (GDP) and in version 3 of the SCIAMACHY Ground Processor (SGP), respectively. The processors are being run at the DLR processing centre on behalf of the European Space Agency (ESA). We first focus on the description of the SDOAS algorithm with particular attention to the impact of uncertainties on the reference O3 absorption cross-sections. Second, the resulting SCIAMACHY total ozone data set is globally evaluated through large-scale comparisons with results from GOME and OMI as well as with ground-based correlative measurements. The various total ozone data sets are found to agree within 2% on average. However, a negative trend of 0.2-0.4%/year has been identified in the SCIAMACHY O3 columns; this probably originates from instrumental degradation effects that have not yet been fully characterized.

  5. Six years of total ozone column measurements from SCIAMACHY nadir observations

    Directory of Open Access Journals (Sweden)

    G. Lichtenberg

    2009-04-01

    Full Text Available Total O3 columns have been retrieved from six years of SCIAMACHY nadir UV radiance measurements using SDOAS, an adaptation of the GDOAS algorithm previously developed at BIRA-IASB for the GOME instrument. GDOAS and SDOAS have been implemented by the German Aerospace Center (DLR in the version 4 of the GOME Data Processor (GDP and in version 3 of the SCIAMACHY Ground Processor (SGP, respectively. The processors are being run at the DLR processing centre on behalf of the European Space Agency (ESA. We first focus on the description of the SDOAS algorithm with particular attention to the impact of uncertainties on the reference O3 absorption cross-sections. Second, the resulting SCIAMACHY total ozone data set is globally evaluated through large-scale comparisons with results from GOME and OMI as well as with ground-based correlative measurements. The various total ozone data sets are found to agree within 2% on average. However, a negative trend of 0.2–0.4%/year has been identified in the SCIAMACHY O3 columns; this probably originates from instrumental degradation effects that have not yet been fully characterized.

  6. Measurement of total body chlorine by prompt gamma in vivo neutron activation analysis

    International Nuclear Information System (INIS)

    Beddoe, A.H.; Streat, S.J.; Hill, G.L.

    1987-01-01

    A method of measuring total body chlorine (TBCl) by prompt gamma in vivo neutron activation analysis is described depending on the same NaI(Tl) spectra used for determinations of total body nitrogen. Ratios of chlorine to hydrogen are derived and TBCl determined using a model of body composition depending on measured body weight, total body water (by tritium dilution) and protein (6.25 x nitrogen) as well as estimated body minerals and glycogen. The precision of the method based on scanning an anthropomorphic phantom is approximately 9% (SD), for a patient dose equivalent of less than 0.30 mSv. Spectra collected from 67 normal volunteers (32 male, 35 female) yielded mean values of TBCl of 72 +- 19 (SD) g in males and 53.6 +- 15 g in females, in broad agreement with values reported by workers using delayed gamma methods. Results are presented for two human cadavers analysed by neutron activation and conventional chemical analysis; the ratios of TBCl (neutron activation) to TBCl (chemical) were 0.980 +- 0.028 (SEM) and 0.91 +- 0.09. It is suggested that an improvement in precision will be achieved by increasing the scanning time (thereby increasing the radiation dose equivalent) and by adding two more detectors. (author)

  7. Measurement of the total antioxidant potential in chronic obstructive pulmonary diseases with a novel automated method

    International Nuclear Information System (INIS)

    Ceylan, E.; Gencer, M.; Uzer, E.; Celik, H.

    2007-01-01

    To determine the oxidative and antioxidative status of plasma of patients with chronic obstructive pulmonary disease (COPD) and to compare these values with healthy smokers and healthy non-smokers control subjects using a more recently developed automated measurement method. This study involved 40 COPD patients, 25 healthy smokers, and 25 non-healthy smokers who attended the Chest Disease Outpatient Clinic in Harran University Research Hospital, Turkey between the period March 2006 and June 2006. We calculated the total antioxidant potential (TAOP) to determine the antioxidative status of plasma and we measured the total peroxide levels to determine the oxidative status of plasma. The TAOP of plasma was significantly lower in patients with COPD than in healthy smokers and healthy non-smokers (p< 0.001). In contrast, the mean total peroxide level of plasma was significantly higher in COPD patients than in healthy smokers and healthy non-smokers (p<0.001). We found a decreased in TAOP COPD patients using a simple, rapid and reliably automated colorimetric assay, which may suitable for use in routine clinical biochemistry laboratory and considerably facilitates the assessment of this useful clinical parameter. We suggest that this novel method may be used as a routine test to evaluate and follow-up the levels of oxidative stress in COPD. (author)

  8. Measurement of the Antiproton-Proton Total Cross-Section at the CERN ISR

    CERN Multimedia

    2002-01-01

    This experiment is a measurement of small angle scattering of antiprotons on protons and of protons on protons at 15/15, 22/22, 26/26 and 31/31 GeV, with the aim of obtaining data on the total cross-section for the scattering of protons on protons, and of determining the ratio of the real to the imaginary scattering amplitude at zero momentum transfer for antiprotons on protons. The measurement is divided into two parts: \\item 1) The measurement of @s^t^o^t(@*p) and @s^t^o^t(pp), using hodoscopes placed at small angles, outside the vacuum pipe, at approximately 9 metres from the intersection point. \\item 2) The measurement of the region in !t!, the momentum transfer squared, around the value !t^c!, where Coulomb and nuclear scattering are equal, in order to deduce the quantity @r = Re f(t=0)/Im f(t=0). This latter measurement is done by employi in earlier @s^t(pp) and @r experiments at the ISR. \\end{enumerate} In both set-ups the measurements are made by recording coincidences between collinear counters in th...

  9. High-Accuracy Measurements of Total Column Water Vapor From the Orbiting Carbon Observatory-2

    Science.gov (United States)

    Nelson, Robert R.; Crisp, David; Ott, Lesley E.; O'Dell, Christopher W.

    2016-01-01

    Accurate knowledge of the distribution of water vapor in Earth's atmosphere is of critical importance to both weather and climate studies. Here we report on measurements of total column water vapor (TCWV) from hyperspectral observations of near-infrared reflected sunlight over land and ocean surfaces from the Orbiting Carbon Observatory-2 (OCO-2). These measurements are an ancillary product of the retrieval algorithm used to measure atmospheric carbon dioxide concentrations, with information coming from three highly resolved spectral bands. Comparisons to high-accuracy validation data, including ground-based GPS and microwave radiometer data, demonstrate that OCO-2 TCWV measurements have maximum root-mean-square deviations of 0.9-1.3mm. Our results indicate that OCO-2 is the first space-based sensor to accurately and precisely measure the two most important greenhouse gases, water vapor and carbon dioxide, at high spatial resolution [1.3 x 2.3 km(exp. 2)] and that OCO-2 TCWV measurements may be useful in improving numerical weather predictions and reanalysis products.

  10. Composite depth dose measurement for total skin electron (TSE) treatments using radiochromic film

    International Nuclear Information System (INIS)

    Gamble, Lisa M; Farrell, Thomas J; Jones, Glenn W; Hayward, Joseph E

    2003-01-01

    Total skin electron (TSE) radiotherapy is routinely used to treat cutaneous T-cell lymphomas and can be implemented using a modified Stanford technique. In our centre, the composite depth dose for this technique is achieved by a combination of two patient positions per day over a three-day cycle, and two gantry angles per patient position. Due to patient morphology, underdosed regions typically occur and have historically been measured using multiple thermoluminescent dosimeters (TLDs). We show that radiochromic film can be used as a two-dimensional relative dosimeter to measure the percent depth dose in TSE radiotherapy. Composite depth dose curves were measured in a cylindrical, polystyrene phantom and compared with TLD data. Both multiple films (1 film per day) and a single film were used in order to reproduce a realistic clinical scenario. First, three individual films were used to measure the depth dose, one per treatment day, and then compared with TLD data; this comparison showed a reasonable agreement. Secondly, a single film was used to measure the dose delivered over three daily treatments and then compared with TLD data; this comparison showed good agreement throughout the depth dose, which includes doses well below 1 Gy. It will be shown that one piece of radiochromic film is sufficient to measure the composite percent depth dose for a TSE beam, hence making radiochromic film a suitable candidate for monitoring underdosed patient regions

  11. Two Methods of Determining Total Phenolic Content of Foods and Juices in a General, Organic, and Biological (GOB) Chemistry Lab

    Science.gov (United States)

    Shaver, Lee Alan; Leung, Sam H.; Puderbaugh, Amy; Angel, Stephen A.

    2011-01-01

    The determination of total phenolics in foods and fruit juices was used successfully as a laboratory experiment in our undergraduate general, organic, and biological (GOB) chemistry course. Two different colorimetric methods were used over three years and comparative student results indicate that a ferrous ammonium sulfate (FAS) indicator…

  12. [Dynamics of total organic carbon (TOC) in hydrological processes in coniferous and broad-leaved mixed forest of Dinghushan].

    Science.gov (United States)

    Yin, Guangcai; Zhou, Guoyi; Zhang, Deqiang; Wang, Xu; Chu, Guowei; Liu, Yan

    2005-09-01

    The total flux and concentration of total organic carbon (TOC) in hydrological processes in coniferous and broad-leaved mixed forest of Dinghushan were measured from July 2002 to July 2003. The results showed that the TOC input by precipitation was 41.80 kg x hm(-2) x yr(-1), while its output by surface runoff and groundwater (soil solution at 50 cm depth) was 17.54 and 1.80 kg x hm(-2) x yr(-1), respectively. The difference between input and output was 22.46 kg x hm(-2) x yr(-1), indicating that the ecosystem TOC was in positive balance. The monthly variation of TOC flux in hydrological processes was very similar to that in precipitation. The mean TOC concentration in precipitation was 3.64 mg x L(-1), while that in throughfall and stemflow increased 6.10 and 7.39 times after rain passed through the tree canopies and barks. The mean TOC concentration in surface runoff and in soil solution at 25 and 50 cm depths was 12.72, 7.905 and 3.06 mg x L(-1), respectively. The monthly TOC concentration in throughfall and stemflow had a similar changing tendency, showing an increase at the beginning of growth season (March), a decrease after September, and a little increase in December. The TOC concentration in runoff was much higher during high precipitation months. No obvious monthly variation was observed in soil solution TOC concentration (25 and 50 cm below the surface). Stemflow TOC concentration differed greatly between different tree species. The TOC concentration in precipitation, throughfall, and soil solution (25 and 50 cm depths) decreased with increasing precipitation, and no significant relationship existed between the TOC concentrations in stemflow, surface runoff and precipitation. The TOC concentrations in the hydrological processes fluctuated with precipitation intensity, except for that in stemflow and soil solutions.

  13. Proportional wire chamber system for beam definition in precision total cross section measurements

    International Nuclear Information System (INIS)

    Carroll, A.S.; Chiang, I.H.; Kycia, T.F.

    1978-03-01

    A PWC system was developed and extensively used in precision measurements of total cross sections at low momenta (0.4 to 1.1 GeV/c) and at high momenta (23 to 370 GeV/c). This ''electronic collimator'' operated simultaneously in a fast (250 nsec) decision making mode, and a slower (0.5 msec) readout mode. The decision making mode utilized adjustable hard-wired logic to define acceptable incident beam trajectories and reject multiple beam tracks. A sample of the events were read into an on-line computer for beam tuning, for chamber diagnostics, and for study of the effect of small angle scattering to verify the total cross section extrapolation procedure

  14. A proportional wire chamber system for beam definition in precision total cross section measurements

    International Nuclear Information System (INIS)

    Carroll, A.S.; Chiang, I.-H.; Kycia, T.F.; Li, K.K.; Mazur, P.O.; Michael, D.N.; Mockett, P.M.; Rahm, D.C.; Rubinstein, R.; Eartly, D.P.; Wehmann, A.A.

    1978-01-01

    The authors have developed and extensively used a PWC system in precision measurements of total cross sections at low momenta (0.4-1.1 GeV/c) and at high momenta (23-370 GeV/c). This 'electronic collimator' operated simultaneously in a fast (250 ns) decision making mode, and a slower (0.5 ms) readout mode. The decision making mode utilized adjustable hardwired logic to define acceptable incident beam trajectories and reject multiple beam tracks. A sample of the events was read into an on-line computer for beam tuning, for chamber diagnostics, and for study of the effect of small angle scattering to verify the total cross section extrapolation procedure. (Auth.)

  15. Measurement of the $Z/A$ dependence of neutrino charged-current total cross-sections

    CERN Document Server

    Kayis-Topaksu, A; Van Dantzig, R; De Jong, M; Konijn, J; Melzer, O; Oldeman, R G C; Pesen, E; Van der Poel, C A F J; Spada, F R; Visschers, J L; Güler, M; Serin-Zeyrek, M; Kama, S; Sever, R; Tolun, P; Zeyrek, M T; Armenise, N; Catanesi, M G; De Serio, M; Ieva, M; Muciaccia, M T; Radicioni, E; Simone, S; Bülte, A; Winter, Klaus; El-Aidi, R; Van de Vyver, B; Vilian, P; Wilquet, G; Saitta, B; Di Capua, E; Ogawa, S; Shibuya, H; Artamonov, A V; Brunner, J; Chizhov, M; Cussans, D G; Doucet, M; Fabre, Jean-Paul; Hristova, I R; Kawamura, T; Kolev, D; Litmaath, M; Meinhard, H; Panman, J; Papadopoulos, I M; Ricciardi, S; Rozanov, A; Saltzberg, D; Tsenov, R V; Uiterwijk, J W E; Zucchelli, P; Goldberg, J; Chikawa, M; Arik, E; Song, J S; Yoon, C S; Kodama, K; Ushida, N; Aoki, S; Hara, T; Delbar, T; Favart, D; Grégoire, G; Kalinin, S; Makhlyoueva, I V; Gorbunov, P; Khovanskii, V D; Shamanov, V V; Tsukerman, I; Bruski, N; Frekers, D; Rondeshagen, D; Wolff, T; Hoshino, K; Kawada, J; Komatsu, M; Miyanishi, M; Nakamura, M; Nakano, T; Narita, K; Niu, K; Niwa, K; Nonaka, N; Sato, O; Toshito, T; Buontempo, S; Cocco, A G; D'Ambrosio, N; De Lellis, G; De Rosa, G; Di Capua, F; Ereditato, A; Fiorillo, G; Marotta, A; Messina, M; Migliozzi, P; Pistillo, C; Santorelli, R; Scotto-Lavina, L; Strolin, P; Tioukov, V; Nakamura, K; Okusawa, T; Dore, U; Loverre, P F; Ludovici, L; Maslennikov, A L; Righini, P; Rosa, G; Santacesaria, R; Satta, A; Barbuto, E; Bozza, C; Grella, G; Romano, G; Sirignano, C; Sorrentino, S; Sato, Y; Tezuka, I

    2003-01-01

    A relative measurement of total cross-sections is reported for polyethylene, marble, iron, and lead targets for the inclusive charged-current reaction nu_mu + N -> mu^- + X. The targets, passive blocks of ~100kg each, were exposed simultaneously to the CERN SPS wide-band muon-neutrino beam over a period of 18 weeks. Systematics effects due to differences in the neutrino flux and detector efficiency for the different target locations were minimised by changing the position of the four targets on their support about every two weeks. The relative neutrino fluxes on the targets were monitored within the same experiment using charged-current interactions in the calorimeter positioned directly downstream of the four targets. From a fit to the Z/A dependence of the total cross-sections a value is deduced for the effective neutron-to-proton cross-section ratio.

  16. Measurement of the Z/A dependence of neutrino charged-current total cross-sections

    CERN Document Server

    Kayis-Topasku, A; Dantzig, R V

    2003-01-01

    A relative measurement of total cross-sections is reported for polyethylene, marble, iron, and lead targets for the inclusive charged-current reaction nu submu + N -> mu sup - + X. The targets, passive blocks of propor to 100 kg each, were exposed simultaneously to the CERN SPS wide-band muon-neutrino beam over a period of 18 weeks. Systematic effects due to differences in the neutrino flux and detector efficiency for the different target locations were minimised by changing the position of the four targets on their support about every two weeks. The relative neutrino fluxes on the targets were monitored within the same experiment using charged-current interactions in the calorimeter positioned directly downstream of the four targets. From a fit to the Z/A dependence of the total cross-sections a value is deduced for the effective neutron-to-proton cross-section ratio. (orig.)

  17. Intra-Cavity Total Reflection For High Sensitivity Measurement Of Optical Properties

    Science.gov (United States)

    Pipino, Andrew Charles Rule

    1999-11-16

    An optical cavity resonator device is provided for conducting sensitive murement of optical absorption by matter in any state with diffraction-limited spatial resolution through utilization of total internal reflection within a high-Q (high quality, low loss) optical cavity. Intracavity total reflection generates an evanescent wave that decays exponentially in space at a point external to the cavity, thereby providing a localized region where absorbing materials can be sensitively probed through alteration of the Q-factor of the otherwise isolated cavity. When a laser pulse is injected into the cavity and passes through the evanescent state, an amplitude loss resulting from absorption is incurred that reduces the lifetime of the pulse in the cavity. By monitoring the decay of the injected pulse, the absorption coefficient of manner within the evanescent wave region is accurately obtained from the decay time measurement.

  18. Total Oxidation of Model Volatile Organic Compounds over Some Commercial Catalysts

    Czech Academy of Sciences Publication Activity Database

    Matějová, Lenka; Topka, Pavel; Jirátová, Květa; Šolcová, Olga

    2012-01-01

    Roč. 443, NOV 7 (2012), s. 40-49 ISSN 0926-860X R&D Projects: GA MPO FR-TI1/059 Institutional support: RVO:67985858 Keywords : volatile organic compounds * oxidation * ethanol Subject RIV: DM - Solid Waste and Recycling Impact factor: 3.410, year: 2012

  19. Measuring business performance using indicators of ecologically sustainable organizations

    Science.gov (United States)

    Snow, Charles G., Jr.; Snow, Charles C.

    2001-02-01

    The purpose of this paper is to explore the use of ecology-based performance measures as a way of augmenting the Balanced Scorecard approach to organizational performance measurement. The Balanced Scorecard, as proposed by Kaplan and Norton, focuses on four primary dimensions; financial, internal-business-process, customer, and learning and growth perspectives. Recently, many 'green' organizational theorists have developed the concept of "Ecologically Sustainable Organizations" or ESOs, a concept rooted in open systems theory. The ESO is called upon to consider resource use and conservation as a strategy for long-term viability. This paper asserts that in order to achieve ESO status, an organization must not only measure but also reward resource conservation measures. Only by adding a fifth perspective for ecological dimensions will the entity be truly motivated toward ESO status.

  20. An updated h-index measures both the primary and total scientific output of a researcher.

    Science.gov (United States)

    Bucur, Octavian; Almasan, Alex; Zubarev, Roman; Friedman, Mark; Nicolson, Garth L; Sumazin, Pavel; Leabu, Mircea; Nikolajczyk, Barbara S; Avram, Dorina; Kunej, Tanja; Calin, George A; Godwin, Andrew K; Adami, Hans-Olov; Zaphiropoulos, Peter G; Richardson, Des R; Schmitt-Ulms, Gerold; Westerblad, Håkan; Keniry, Megan; Grau, Georges E R; Carbonetto, Salvatore; Stan, Radu V; Popa-Wagner, Aurel; Takhar, Kasumov; Baron, Beverly W; Galardy, Paul J; Yang, Feng; Data, Dipak; Fadare, Oluwole; Yeo, Kt Jerry; Gabreanu, Georgiana R; Andrei, Stefan; Soare, Georgiana R; Nelson, Mark A; Liehn, Elisa A

    2015-01-01

    The growing interest in scientometry stems from ethical concerns related to the proper evaluation of scientific contributions of an author working in a hard science. In the absence of a consensus, institutions may use arbitrary methods for evaluating scientists for employment and promotion. There are several indices in use that attempt to establish the most appropriate and suggestive position of any scientist in the field he/she works in. A scientist's Hirsch-index (h-index) quantifies their total effective published output, but h-index summarizes the total value of their published work without regard to their contribution to each publication. Consequently, articles where the author was a primary contributor carry the same weight as articles where the author played a minor role. Thus, we propose an updated h-index named Hirsch(p,t)-index that informs about both total scientific output and output where the author played a primary role. Our measure, h(p,t) = h(p),h(t), is composed of the h-index h(t) and the h-index calculated for articles where the author was a key contributor; i.e. first/shared first or senior or corresponding author. Thus, a h(p,t) = 5,10 would mean that the author has 5 articles as first, shared first, senior or corresponding author with at least 5 citations each, and 10 total articles with at least 10 citations each. This index can be applied in biomedical disciplines and in all areas where the first and last position on an article are the most important. Although other indexes, such as r- and w-indexes, were proposed for measuring the authors output based on the position of researchers within the published articles, our simpler strategy uses the already established algorithms for h-index calculation and may be more practical to implement.

  1. Centennial-scale records of total organic carbon in sediment cores from the South Yellow Sea, China

    Science.gov (United States)

    Zhu, Qing; Lin, Jia; Hong, Yuehui; Yuan, Lirong; Liu, Jinzhong; Xu, Xiaoming; Wang, Jianghai

    2018-01-01

    Global carbon cycling is a significant factor that controls climate change. The centennial-scale variations in total organic carbon (TOC) contents and its sources in marginal sea sediments may reflect the influence of human activities on global climate change. In this study, two fine-grained sediment cores from the Yellow Sea Cold Water Mass of the South Yellow Sea were used to systematically determine TOC contents and stable carbon isotope ratios. These results were combined with previous data of black carbon and 210Pb dating from which we reconstructed the centennial-scale initial sequences of TOC, terrigenous TOC (TOCter) and marine autogenous TOC (TOCmar) after selecting suitable models to correct the measured TOC (TOCcor). These sequences showed that the TOCter decreased with time in the both cores while the TOCmar increased, particularly the rapid growth in core H43 since the late 1960s. According to the correlation between the Huanghe (Yellow) River discharge and the TOCcor, TOCter, or TOCmar, we found that the TOCter in the two cores mainly derived from the Huanghe River and was transported by it, and that higher Huanghe River discharge could strengthen the decomposition of TOCmar. The newly obtained initial TOC sequences provide important insights into the interaction between human activities and natural processes.

  2. Measurement of the elastic, total and diffraction cross sections at tevatron energies

    International Nuclear Information System (INIS)

    Belforte, S.

    1993-11-01

    The CDF collaboration has measured the differential elastic cross section dσ el /dt, the single diffraction dissociation double differential cross section d 2 σ sd /dM 2 dt and the total inelastic cross section for antiproton-proton collisions at center of mass energies √s = 546 and 1,800 GeV. Data for this measurement have been collected in short dedicated runs during the 1988--1989 data taking period of CDF. The elastic scattering slope is 15.28 ± 0.58 (16.98 ± 0.25) GeV -2 at √s = 546 (1,800) GeV. Using the luminosity independent method (1 + ρ 2 )σ T is measured to be 62.64 ± 0.95 (81.83 ± 2.29) mb at √s = 546 (1,800) GeV. Assuming ρ = 0.15 the elastic, total and single diffraction cross sections are σ el = 12.87 ± 0.30, σ T = 61.26 ± 0.93 and σ sd = 7.89 ± 0.33 mb (σ el = 19.70 ± 0.85, σ T = 80.03 ± 2.24 and σ sd = 9.46 ± 0.44 mb) at √s = 546 (1,800) GeV

  3. A new fully automated FTIR system for total column measurements of greenhouse gases

    Directory of Open Access Journals (Sweden)

    M. C. Geibel

    2010-10-01

    Full Text Available This article introduces a new fully automated FTIR system that is part of the Total Carbon Column Observing Network (TCCON. It will provide continuous ground-based measurements of column-averaged volume mixing ratio for CO2, CH4 and several other greenhouse gases in the tropics.

    Housed in a 20-foot shipping container it was developed as a transportable system that could be deployed almost anywhere in the world. We describe the automation concept which relies on three autonomous subsystems and their interaction. Crucial components like a sturdy and reliable solar tracker dome are described in detail. The automation software employs a new approach relying on multiple processes, database logging and web-based remote control.

    First results of total column measurements at Jena, Germany show that the instrument works well and can provide parts of the diurnal as well as seasonal cycle for CO2. Instrument line shape measurements with an HCl cell suggest that the instrument stays well-aligned over several months.

    After a short test campaign for side by side intercomaprison with an existing TCCON instrument in Australia, the system will be transported to its final destination Ascension Island.

  4. A new fully automated FTIR system for total column measurements of greenhouse gases

    Science.gov (United States)

    Geibel, M. C.; Gerbig, C.; Feist, D. G.

    2010-10-01

    This article introduces a new fully automated FTIR system that is part of the Total Carbon Column Observing Network (TCCON). It will provide continuous ground-based measurements of column-averaged volume mixing ratio for CO2, CH4 and several other greenhouse gases in the tropics. Housed in a 20-foot shipping container it was developed as a transportable system that could be deployed almost anywhere in the world. We describe the automation concept which relies on three autonomous subsystems and their interaction. Crucial components like a sturdy and reliable solar tracker dome are described in detail. The automation software employs a new approach relying on multiple processes, database logging and web-based remote control. First results of total column measurements at Jena, Germany show that the instrument works well and can provide parts of the diurnal as well as seasonal cycle for CO2. Instrument line shape measurements with an HCl cell suggest that the instrument stays well-aligned over several months. After a short test campaign for side by side intercomaprison with an existing TCCON instrument in Australia, the system will be transported to its final destination Ascension Island.

  5. INVESTIGATION OF THE TOTAL ORGANIC HALOGEN ANALYTICAL METHOD AT THE WASTE SAMPLING AND CHARACTERIZATION FACILITY

    International Nuclear Information System (INIS)

    Douglas, J.G.; Meznarich, H.K.; Olsen, J.R.; Ross, G.A.; Stauffer, M.

    2009-01-01

    Total organic halogen (TOX) is used as a parameter to screen groundwater samples at the Hanford Site. Trending is done for each groundwater well, and changes in TOX and other screening parameters can lead to costly changes in the monitoring protocol. The Waste Sampling and Characterization Facility (WSCF) analyzes groundwater samples for TOX using the United States Environmental Protection Agency (EPA) SW-S46 method 9020B (EPA 1996a). Samples from the Soil and Groundwater Remediation Project (SGRP) are submitted to the WSCF for analysis without information regarding the source of the sample; each sample is in essence a ''blind'' sample to the laboratory. Feedback from the SGRP indicated that some of the WSCF-generated TOX data from groundwater wells had a number of outlier values based on the historical trends (Anastos 200Sa). Additionally, analysts at WSCF observed inconsistent TOX results among field sample replicates. Therefore, the WSCF lab performed an investigation of the TOX analysis to determine the cause of the outlier data points. Two causes were found that contributed to generating out-of-trend TOX data: (1) The presence of inorganic chloride in the groundwater samples: at inorganic chloride concentrations greater than about 10 parts per million (ppm), apparent TOX values increase with increasing chloride concentration. A parallel observation is the increase in apparent breakthrough of TOX from the first to the second activated-carbon adsorption tubes with increasing inorganic chloride concentration. (2) During the sample preparation step, excessive purging of the adsorption tubes with oxygen pressurization gas after sample loading may cause channeling in the activated carbon bed. This channeling leads to poor removal of inorganic chloride during the subsequent wash step with aqueous potassium nitrate. The presence of this residual inorganic chloride then produces erroneously high TOX values. Changes in sample preparation were studied to more effectively

  6. The Relation among School District Health, Total Quality Principles for School Organization and Student Achievement

    Science.gov (United States)

    Marshall, Jon; Pritchard, Ruie; Gunderson, Betsey

    2004-01-01

    The purpose of this study was to determine the congruence among W. E. Deming's 14 points for Total Quality Management (TQM), the organizational health of school districts, and student achievement. Based on Kanter's (1983) concept of a Culture of Pride with a Climate of Success, healthy districts were defined as having an organizational culture…

  7. Measuring and Communicating the Value Created by an Organization

    Science.gov (United States)

    Sherman, W. Richard

    2010-01-01

    This paper offers a different perspective in measuring the value created by an organization. It does so in the context of an undergraduate course in managerial accounting. In order to break down the functional silo approach to problem solving that has become the model of traditional business education, applications of shadow accounting, the…

  8. Blood, carcass and organ measurements as influenced by ...

    African Journals Online (AJOL)

    Effects of feeding Aspergillus treated cassava wastes on haematological values, organs and carcass measurements of West African dwarf goats (WAD) were determined. Twelve West African dwarf goats (weighing between 2.8 and 5.4kg) in a completely randomized design (CRD) model with 56d periods consumed diets A ...

  9. Inexpensive Measuring System for the Characterization of Organic Transistors

    Directory of Open Access Journals (Sweden)

    Clara Pérez-Fuster

    2018-01-01

    Full Text Available A measuring module has been specifically designed for the electrical characterization of organic semiconductor devices such as organic field effect transistors (OFETs and organic electrochemical transistors (OECTs according to the IEEE 1620-2008 standard. This device has been tested with OFETs based on 6,13-bis(triisopropylsilylethinylpentacene (TIPS-pentacene. The measuring system has been constructed using a NI-PXIe-1073 chassis with integrated controller and two NI-PXI-4132 programmable high-precision source measure units (SMUs that offer a four-quadrant ± 100 V output, with resolution down to 10 pA. LabVIEW™ has been used to develop the appropriate program. Most of the main OFET parameters included in the IEEE 1620 standard can be measured by means of this device. Although nowadays expensive devices for the characterization of Si-based transistors are available, devices for the characterization of organic transistors are not yet widespread in the market. Fabrication of a specific and flexible module that can be used to characterize this type of transistors would provide a powerful tool to researchers.

  10. Measurements of inelastic, elastic and total pp cross-sections at the LHC with ATLAS

    CERN Document Server

    Trottier-McDonald, Michel; The ATLAS collaboration

    2015-01-01

    First, a recent measurement of the inelastic cross section using the ATLAS detector with 63 $\\mu b^{−1}$ of proton-proton collisions at $\\sqrt{s}=13$ TeV is presented. The measurement is performed using scintillators mounted in front of the forward calorimeters. A cross section of $65.2\\pm0.8$ (exp.) $\\pm5.9$ (lum.) mb is measured in the fiducial region $M_X>13$ GeV, where $M_X$ is the larger of the dissociation masses of the two proton systems in diffractive events. The experimental uncertainty is indicated by (exp.) and the luminosity uncertainty by (lum.). The full inelastic cross section is determined to be $73.1\\pm0.9$ (exp.) $\\pm6.6$ (lum.) $\\pm3.8$ (extr.) mb, where (extr.) indicates model-dependent uncertainties on the extrapolation from the fiducial region. The measured value is about one standard deviation below most current theoretical predictions. Second, a measurement of the total $pp$ cross section at the LHC at $\\sqrt{s}=7$ TeV is presented. In a special run with high-$\\beta^*$ beam optics, a...

  11. A pilot study to validate measures of the theory of reasoned action for organ donation behavior.

    Science.gov (United States)

    Wong, Shui Hung; Chow, Amy Yin Man

    2018-04-01

    The present study aimed at taking the first attempt in validating the measures generated based on the theory of reasoned action (TRA). A total of 211 university students participated in the study, 95 were included in the exploratory factor analysis and 116 were included in the confirmatory factor analysis. The TRA measurements were established with adequate psychometric properties, internal consistency, and construct validity. Findings also suggested that attitude toward organ donation has both a cognitive and affective nature, while the subjective norm of the family seems to be important to students' views on organ donation.

  12. μTAS (micro total analysis systems) for the high-throughput measurement of nanomaterial solubility

    International Nuclear Information System (INIS)

    Tantra, R; Jarman, J

    2013-01-01

    There is a consensus in the nanoecotoxicology community that better analytical tools i.e. faster and more accurate ones, are needed for the physicochemical characterisation of nanomaterials in environmentally/biologically relevant media. In this study, we introduce the concept of μTAS (Micro Total Analysis Systems), which was a term coined to encapsulate the integration of laboratory processes on a single microchip. Our focus here is on the use of a capillary electrophoresis (CE) with conductivity detection microchip and how this may be used for the measurement of dissolution of metal oxide nanomaterials. Our preliminary results clearly show promise in that the device is able to: a) measure ionic zinc in various ecotox media with high selectivity b) track the dynamic dissolution events of zinc oxide (ZnO) nanomaterial when dispersed in fish medium.

  13. Prediction of midline dose from entrance ad exit dose using OSLD measurements for total irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Chang Heon; Park, Jong Min; Park, So Yeon; Chun, Min Soo; Han, Ji Hye; Cho, Jin Dong; Kim, Jung In [Dept. of Radiation Oncology, Seoul National University Hospital, Seoul (Korea, Republic of)

    2017-06-15

    This study aims to predict the midline dose based on the entrance and exit doses from optically stimulated luminescence detector (OSLD) measurements for total body irradiation (TBI). For TBI treatment, beam data sets were measured for 6 MV and 15 MV beams. To evaluate the tissue lateral effect of various thicknesses, the midline dose and peak dose were measured using a solid water phantom (SWP) and ion chamber. The entrance and exit doses were measured using OSLDs. OSLDs were attached onto the central beam axis at the entrance and exit surfaces of the phantom. The predicted midline dose was evaluated as the sum of the entrance and exit doses by OSLD measurement. The ratio of the entrance dose to the exit dose was evaluated at various thicknesses. The ratio of the peak dose to the midline dose was 1.12 for a 30 cm thick SWP at both energies. When the patient thickness is greater than 30 cm, the 15 MV should be used to ensure dose homogeneity. The ratio of the entrance dose to the exit dose was less than 1.0 for thicknesses of less than 30 cm and 40 cm at 6 MV and 15 MV, respectively. Therefore, the predicted midline dose can be underestimated for thinner body. At 15 MV, the ratios were approximately 1.06 for a thickness of 50 cm. In cases where adult patients are treated with the 15 MV photon beam, it is possible for the predicted midline dose to be overestimated for parts of the body with a thickness of 50 cm or greater. The predicted midline dose and OSLD-measured midline dose depend on the phantom thickness. For in-vivo dosimetry of TBI, the measurement dose should be corrected in order to accurately predict the midline dose.

  14. Comparison of total protein concentration in skeletal muscle as measured by the Bradford and Lowry assays.

    Science.gov (United States)

    Seevaratnam, Rajini; Patel, Barkha P; Hamadeh, Mazen J

    2009-06-01

    The Lowry and Bradford assays are the most commonly used methods of total protein quantification, yet vary in several aspects. To date, no comparisons have been made in skeletal muscle. We compared total protein concentrations of mouse red and white gastrocnemius, reagent stability, protein stability and range of linearity using both assays. The Lowry averaged protein concentrations 15% higher than the Bradford with a moderate correlation (r = 0.36, P = 0.01). However, Bland-Altman analysis revealed considerable bias (15.8 +/- 29.7%). Both Lowry reagents and its protein-reagent interactions were less stable over time than the Bradford. The linear range of concentration was smaller for the Lowry (0.05-0.50 mg/ml) than the Bradford (0-2.0 mg/ml). We conclude that the Bradford and Lowry measures of total protein concentration in skeletal muscle are not interchangeable. The Bradford and Lowry assays have various strengths and weaknesses in terms of substance interference and protein size. However, the Bradford provides greater reagent stability, protein-reagent stability and range of linearity, and requires less time to analyse compared to the Lowry assay.

  15. Measurement of the total proton-proton cross section with ATLAS at LHC

    CERN Document Server

    khalek, Samah Abdel

    It is now nearly fifty years since total proton-proton (pp) cross sections have been found to grow with energy after it was believed for long time that they would become asymptotically constant . The uncertainties of the cosmic ray data, at high energy, do not allow to determine the exact growth with energy of the total cross section .The Large Hadron Collider (LHC) at CERN in Geneva has already delivered collisions with an energy never reached in a particle accelerator. The energy in the center of mass was 7 TeV (2010 - 2011) or 8 TeV (2012) and will ultimately reached 14 TeV in the near future. Thus, this will provide a good environment for a new precise measurement of the total pp cross section at this energy.The ATLAS detector installed in one of the four LHC interaction points is used to collect the result of the pp collisions. Its sub-detector ALFA located 240 m from the interaction point, is used to track protons resulting from elastic collisions.Therefore, within special beam optics conditions, ALFA i...

  16. Resonance structure of 32S+n from measurements of neutron total and capture cross sections

    International Nuclear Information System (INIS)

    Halperin, J.; Johnson, C.H.; Winters, R.R.; Macklin, R.L.

    1980-01-01

    Neutron total and capture cross sections of 32 S have been measured up to 1100 keV neutron energy [E/sub exc/( 33 S) =9700 keV]. Spin and parity assignments have been made for 28 of the 64 resonances found in this region. Values of total radiation widths, reduced neutron widths, level spacings, and neutron strength functions have been evaluated for s/sub 1/2/, p/sub 1/2/, p/sub 3/2/, and d/sub 5/2/ levels. Single particle contributions using the valency model account for a significant portion of the total radiation width only for the p/sub 1/2/-wave resonances. A significant number of resonances can be identified with reported levels excited in 32 S(d,p) and 29 Si(α,n) reactions. A calculation of the Maxwellian average cross section appropriate to stellar interiors indicates an average capture cross section at 30 keV, sigma-bar approx. = 4.2(2) mb, a result that is relatively insensitive to the assumed stellar temperature. Direct (potential) capture and the s-wave resonance capture contributions to the thermal capture cross section do not fully account for the reported thermal cross section (530 +- 40 mb) and a bound state is invoked to account for the discrepancy

  17. Aged organic aerosol in the Eastern Mediterranean: the Finokalia Aerosol Measurement Experiment – 2008

    Directory of Open Access Journals (Sweden)

    L. Hildebrandt

    2010-05-01

    Full Text Available Aged organic aerosol (OA was measured at a remote coastal site on the island of Crete, Greece during the Finokalia Aerosol Measurement Experiment-2008 (FAME-2008, which was part of the EUCAARI intensive campaign of May 2008. The site at Finokalia is influenced by air masses from different source regions, including long-range transport of pollution from continental Europe. A quadrupole aerosol mass spectrometer (Q-AMS was employed to measure the size-resolved chemical composition of non-refractory submicron aerosol (NR-PM1, and to estimate the extent of oxidation of the organic aerosol. Factor analysis was used to gain insights into the processes and sources affecting the OA composition. The particles were internally mixed and liquid. The largest fraction of the dry NR-PM1 sampled was ammonium sulfate and ammonium bisulfate, followed by organics and a small amount of nitrate. The variability in OA composition could be explained with two factors of oxygenated organic aerosol (OOA with differing extents of oxidation but similar volatility. Hydrocarbon-like organic aerosol (HOA was not detected. There was no statistically significant diurnal variation in the bulk composition of NR-PM1 such as total sulfate or total organic aerosol concentrations. However, the OA composition exhibited statistically significant diurnal variation with more oxidized OA in the afternoon. The organic aerosol was highly oxidized, regardless of the source region. Total OA concentrations also varied little with source region, suggesting that local sources had only a small effect on OA concentrations measured at Finokalia. The aerosol was transported for about one day before arriving at the site, corresponding to an OH exposure of approximately 4×1011 molecules cm−3 s. The constant extent of oxidation suggests that atmospheric aging results in a highly oxidized OA at these OH exposures, regardless of the aerosol source.

  18. Absolute luminosity and proton-proton total cross section measurement for the ATLAS experiment at LHC

    International Nuclear Information System (INIS)

    Heller, Matthieu

    2010-01-01

    The Large Hadron Collider (LHC) at CERN in Geneva will soon deliver collisions with an energy never reached in a particle accelerator. An energy in the center of mass of 10 and ultimately 14 TeV will allow to go beyond the borders of the physics known so far. ATLAS, the largest detector ever built, will hunt the Higgs boson and search for new physics beyond the Standard Model. Any physical process is described by a cross section that measures its probability to occur. The events resulting from a given process are registered by ATLAS. To determine their according cross section, one has to know the luminosity. For the ATLAS experiment, a relative measurement of the luminosity can be done using the response of several sub-detectors. However to calibrate these detectors, an absolute measurement has to be performed. The ALFA detector has been designed to measure the elastic scattering spectrum that will allow to determine the absolute luminosity and the proton-proton total cross section. This provides an accurate calibration tool at a percent level. These detectors, located 240 m away from the interaction point, are called roman pots, a mechanical system that allows to approach a scintillating fiber tracker a few millimeters to the beam center. The simulation of the measurement requires to use a charged particles transport program. This program has to be carefully chosen because the determination of the protons lost during their travel from the interaction point to the detector has a major impact on the acceptance computation. The systematical uncertainties affecting the luminosity and the total cross section measurements are also determined using the full simulation chain. The ALFA detector operates in a complex environment and consequently its design requires a great care. A large tests campaign has been performed on the front end electronics. The results and the corresponding data analysis have shown that all requirement where fulfilled. A test beam has been

  19. Accuracy of total oxidant measurement as obtained by the phenolphthalin method

    Energy Technology Data Exchange (ETDEWEB)

    Louw, C W; Halliday, E C

    1963-01-01

    The phenolphthalin method of Haagen-Smit and Brunelle (1958) was chosen for a preliminary survey of total oxidant level in Pretoria air, because of its sensitivity. Difficulty, however, was encountered in obtaining reliable standard curves. Some improvement was obtained when conducting all operations except photometer measurements at the temperature of melting ice. It was also found that when the sequence of adding the reagents was changed, so as to simulate conditions during actual sampling, a standard curve approximating a straight line and differing considerably from that of McCabe (1953) was obtained. It follows that values of total oxidant obtained by any experimentor will depend to a certain extent upon the method of standard curve preparation he uses, and when comparisons are made between measurements by experimentors in different towns or countries this factor should be taken into consideration. The accuracy (95% confidence) obtained by the phenolphthalin method, using the mean of three successive samples, was shown to be in the region of 30% for very low amounts of oxidant.

  20. Measurements and modeling of total solar irradiance in X-class solar flares

    International Nuclear Information System (INIS)

    Moore, Christopher Samuel; Chamberlin, Phillip Clyde; Hock, Rachel

    2014-01-01

    The Total Irradiance Monitor (TIM) from NASA's SOlar Radiation and Climate Experiment can detect changes in the total solar irradiance (TSI) to a precision of 2 ppm, allowing observations of variations due to the largest X-class solar flares for the first time. Presented here is a robust algorithm for determining the radiative output in the TIM TSI measurements, in both the impulsive and gradual phases, for the four solar flares presented in Woods et al., as well as an additional flare measured on 2006 December 6. The radiative outputs for both phases of these five flares are then compared to the vacuum ultraviolet (VUV) irradiance output from the Flare Irradiance Spectral Model (FISM) in order to derive an empirical relationship between the FISM VUV model and the TIM TSI data output to estimate the TSI radiative output for eight other X-class flares. This model provides the basis for the bolometric energy estimates for the solar flares analyzed in the Emslie et al. study.

  1. Objectively Measured Total and Occupational Sedentary Time in Three Work Settings

    Science.gov (United States)

    van Dommelen, Paula; Coffeng, Jennifer K.; van der Ploeg, Hidde P.; van der Beek, Allard J.; Boot, Cécile R. L.; Hendriksen, Ingrid J. M.

    2016-01-01

    Background Sedentary behaviour increases the risk for morbidity. Our primary aim is to determine the proportion and factors associated with objectively measured total and occupational sedentary time in three work settings. Secondary aim is to study the proportion of physical activity and prolonged sedentary bouts. Methods Data were obtained using ActiGraph accelerometers from employees of: 1) a financial service provider (n = 49 men, 31 women), 2) two research institutes (n = 30 men, 57 women), and 3) a construction company (n = 38 men). Total (over the whole day) and occupational sedentary time, physical activity and prolonged sedentary bouts (lasting ≥30 minutes) were calculated by work setting. Linear regression analyses were performed to examine general, health and work-related factors associated with sedentary time. Results The employees of the financial service provider and the research institutes spent 76–80% of their occupational time in sedentary behaviour, 18–20% in light intensity physical activity and 3–5% in moderate-to-vigorous intensity physical activity. Occupational time in prolonged sedentary bouts was 27–30%. Total time was less sedentary (64–70%), and had more light intensity physical activity (26–33%). The employees of the construction company spent 44% of their occupational time in sedentary behaviour, 49% in light, and 7% in moderate intensity physical activity, and spent 7% in sedentary bouts. Total time spent in sedentary behavior was 56%, 40% in light, and 4% in moderate intensity physical behaviour, and 12% in sedentary bouts. For women, low to intermediate education was the only factor that was negatively associated with occupational sedentary time. Conclusions Sedentary behaviour is high among white-collar employees, especially in highly educated women. A relatively small proportion of sedentary time was accrued in sedentary bouts. It is recommended that worksite health promotion efforts should focus on reducing sedentary

  2. Measurement of total ultrasonic power using thermal expansion and change in buoyancy of an absorbing target.

    Science.gov (United States)

    Dubey, P K; Kumar, Yudhisther; Gupta, Reeta; Jain, Anshul; Gohiya, Chandrashekhar

    2014-05-01

    The Radiation Force Balance (RFB) technique is well established and most widely used for the measurement of total ultrasonic power radiated by ultrasonic transducer. The technique is used as a primary standard for calibration of ultrasonic transducers with relatively fair uncertainty in the low power (below 1 W) regime. In this technique, uncertainty comparatively increases in the range of few watts wherein the effects such as thermal heating of the target, cavitations, and acoustic streaming dominate. In addition, error in the measurement of ultrasonic power is also caused due to movement of absorber at relatively high radiated force which occurs at high power level. In this article a new technique is proposed which does not measure the balance output during transducer energized state as done in RFB. It utilizes the change in buoyancy of the absorbing target due to local thermal heating. The linear thermal expansion of the target changes the apparent mass in water due to buoyancy change. This forms the basis for the measurement of ultrasonic power particularly in watts range. The proposed method comparatively reduces uncertainty caused by various ultrasonic effects that occur at high power such as overshoot due to momentum of target at higher radiated force. The functionality of the technique has been tested and compared with the existing internationally recommended RFB technique.

  3. Measurement of Deformations by MEMS Arrays, Verified at Sub-millimetre Level Using Robotic Total Stations

    Directory of Open Access Journals (Sweden)

    Tomas Beran

    2014-06-01

    Full Text Available Measurement of sub-millimetre-level deformations of structures in the presence of ambienttemperature changes can be challenging. This paper describes the measurement of astructure moving due to temperature changes, using two ShapeAccelArray (SAAinstruments, and verified by a geodetic monitoring system. SAA is a geotechnicalinstrument often used for monitoring of displacements in soil. SAA uses micro-electro-mechanical system (MEMS sensors to measure tilt in the gravity field. The geodeticmonitoring system, which uses ALERT software, senses the displacements of targetsrelative to control points, using a robotic total station (RTS. The test setup consists of acentral four-metre free-standing steel tube with other steel tubes welded to most of itslength. The central tube is anchored in a concrete foundation. This composite “pole” isequipped with two SAAs as well as three geodetic prisms mounted on the top, in the middle,and in the foundation. The geodetic system uses multiple control targets mounted inconcrete foundations of nearby buildings, and at the base of the pole. Long-termobservations using two SAAs indicate that the pole is subject to deformations due to cyclicalambient temperature variations causing the pole to move by a few millimetres each day. Ina multiple-day experiment, it was possible to track this movement using SAA as well as theRTS system. This paper presents data comparing the measurements of the two instrumentsand provides a good example of the detection of two-dimensional movements of seeminglyrigid objects due to temperature changes.

  4. Solid State Sensor for Simultaneous Measurement of Total Alkalinity and pH of Seawater.

    Science.gov (United States)

    Briggs, Ellen M; Sandoval, Sergio; Erten, Ahmet; Takeshita, Yuichiro; Kummel, Andrew C; Martz, Todd R

    2017-09-22

    A novel design is demonstrated for a solid state, reagent-less sensor capable of rapid and simultaneous measurement of pH and Total Alkalinity (A T ) using ion sensitive field effect transistor (ISFET) technology to provide a simplified means of characterization of the aqueous carbon dioxide system through measurement of two "master variables": pH and A T . ISFET-based pH sensors that achieve 0.001 precision are widely used in various oceanographic applications. A modified ISFET is demonstrated to perform a nanoliter-scale acid-base titration of A T in under 40 s. This method of measuring A T , a Coulometric Diffusion Titration, involves electrolytic generation of titrant, H + , through the electrolysis of water on the surface of the chip via a microfabricated electrode eliminating the requirement of external reagents. Characterization has been performed in seawater as well as titrating individual components (i.e., OH - , HCO 3 - , CO 3 2- , B(OH) 4 - , PO 4 3- ) of seawater A T . The seawater measurements are consistent with the design in reaching the benchmark goal of 0.5% precision in A T over the range of seawater A T of ∼2200-2500 μmol kg -1 which demonstrates great potential for autonomous sensing.

  5. Measurement of total ultrasonic power using thermal expansion and change in buoyancy of an absorbing target

    Science.gov (United States)

    Dubey, P. K.; Kumar, Yudhisther; Gupta, Reeta; Jain, Anshul; Gohiya, Chandrashekhar

    2014-05-01

    The Radiation Force Balance (RFB) technique is well established and most widely used for the measurement of total ultrasonic power radiated by ultrasonic transducer. The technique is used as a primary standard for calibration of ultrasonic transducers with relatively fair uncertainty in the low power (below 1 W) regime. In this technique, uncertainty comparatively increases in the range of few watts wherein the effects such as thermal heating of the target, cavitations, and acoustic streaming dominate. In addition, error in the measurement of ultrasonic power is also caused due to movement of absorber at relatively high radiated force which occurs at high power level. In this article a new technique is proposed which does not measure the balance output during transducer energized state as done in RFB. It utilizes the change in buoyancy of the absorbing target due to local thermal heating. The linear thermal expansion of the target changes the apparent mass in water due to buoyancy change. This forms the basis for the measurement of ultrasonic power particularly in watts range. The proposed method comparatively reduces uncertainty caused by various ultrasonic effects that occur at high power such as overshoot due to momentum of target at higher radiated force. The functionality of the technique has been tested and compared with the existing internationally recommended RFB technique.

  6. Measurement of total ultrasonic power using thermal expansion and change in buoyancy of an absorbing target

    International Nuclear Information System (INIS)

    Dubey, P. K.; Kumar, Yudhisther; Gupta, Reeta; Jain, Anshul; Gohiya, Chandrashekhar

    2014-01-01

    The Radiation Force Balance (RFB) technique is well established and most widely used for the measurement of total ultrasonic power radiated by ultrasonic transducer. The technique is used as a primary standard for calibration of ultrasonic transducers with relatively fair uncertainty in the low power (below 1 W) regime. In this technique, uncertainty comparatively increases in the range of few watts wherein the effects such as thermal heating of the target, cavitations, and acoustic streaming dominate. In addition, error in the measurement of ultrasonic power is also caused due to movement of absorber at relatively high radiated force which occurs at high power level. In this article a new technique is proposed which does not measure the balance output during transducer energized state as done in RFB. It utilizes the change in buoyancy of the absorbing target due to local thermal heating. The linear thermal expansion of the target changes the apparent mass in water due to buoyancy change. This forms the basis for the measurement of ultrasonic power particularly in watts range. The proposed method comparatively reduces uncertainty caused by various ultrasonic effects that occur at high power such as overshoot due to momentum of target at higher radiated force. The functionality of the technique has been tested and compared with the existing internationally recommended RFB technique

  7. A neutron detector for measurement of total neutron production cross sections

    Energy Technology Data Exchange (ETDEWEB)

    Sekharan, K K; Laumer, H; Kern, B D; Gabbard, F [Kentucky Univ., Lexington (USA). Dept. of Physics and Astronomy

    1976-03-01

    A neutron detector has been constructed and calibrated for the accurate measurement of total neutron production cross sections. The detector consists of a polyethylene sphere of 60 cm diameter in which eight /sup 10/BF/sub 3/ counters have been installed radially. The relative efficiency of this detector has been determined for average neutron energies from 30 keV to 1.5 MeV by counting neutrons from /sup 7/Li(p, n)/sup 7/Be. By adjusting the radial positions of the BF/sub 3/ counters in the polyethylene sphere the efficiency for neutron detection was made nearly constant for this energy range. Measurement of absolute efficiency for the same neutron energy range has been done by counting the neutrons from /sup 51/V(p, n)/sup 51/Cr and /sup 57/Fe(p, n)/sup 57/Co reactions and determining the absolute number of residual nuclei produced during the measurement of neutron yield. Details of absolute efficiency measurements and the use of the detector for determination of neutron production cross sections are given.

  8. A neutron detector for measurement of total neutron production cross sections

    International Nuclear Information System (INIS)

    Sekharan, K.K.; Laumer, H.; Kern, B.D.; Gabbard, F.

    1976-01-01

    A neutron detector has been constructed and calibrated for the accurate measurement of total neutron production cross sections. The detector consists of a polyethylene sphere of 60 cm diameter in which eight 10 BF 3 counters have been installed radially. The relative efficiency of this detector has been determined for average neutron energies from 30 keV to 1.5 MeV by counting neutrons from 7 Li(p, n) 7 Be. By adjusting the radial positions of the BF 3 counters in the polyethylene sphere the efficiency for neutron detection was made nearly constant for this energy range. Measurement of absolute efficiency for the same neutron energy range has been done by counting the neutrons from 51 V(p, n) 51 Cr and 57 Fe(p, n) 57 Co reactions and determining the absolute number of residual nuclei produced during the measurement of neutron yield. Details of absolute efficiency measurements and the use of the detector for determination of neutron production cross sections are given. (Auth.)

  9. Total organic carbon and humus fractions in restored soils from limestone quarries in semiarid climate, SE Spain

    Science.gov (United States)

    Luna Ramos, Lourdes; Miralles Mellado, Isabel; Ángel Domene Ruiz, Miguel; Solé Benet, Albert

    2016-04-01

    Mining activities generate erosion and loss of plant cover and soil organic matter (SOM), especially in arid and semiarid Mediterranean regions. A precondition for ecosystem restoration in such highly disturbed areas is the development of functional soils with sufficient organic matter. But the SOM quality is also important to long-term C stabilization. The resistance to biodegradation of recalcitrant organic matter fractions has been reported to depend on some intrinsic structural factors of humic acid substances and formation of amorphous organo-mineral recalcitrant complexes. In an experimental soil restoration in limestone quarries in the Sierra de Gádor (Almería), SE Spain, several combinations of organic amendments (sewage sludge and compost from domestic organic waste) and mulches (gravel and woodchip) were added in experimental plots using a factorial design. In each plot, 75 native plants (Anthyllis cytisoides, A. terniflora and Macrochloa tenacissima) were planted and five years after the start of the experiment total organic carbon (TOC), physico-chemical soil properties and organic C fractions (particulate organic matter, H3PO4-fulvic fraction, fulvic acids (FA), humic acids (HA) and humin) were analyzed. We observed significant differences between treatments related to the TOC content and the HA/FA ratio. Compost amendments increased the TOC, HA content and HA/FA ratio, even higher than in natural undisturbed soils, indicating an effective clay humus-complex pointing to progressively increasing organic matter quality. Soils with sewage sludge showed the lowest TOC and HA/FA ratio and accumulated a lower HA proportion indicating poorer organic matter quality and comparatively lower resilience than in natural soils and soils amended with compost.

  10. Reliability of measuring hip abductor strength following total knee arthroplasty using a hand-held dynamometer.

    Science.gov (United States)

    Schache, Margaret B; McClelland, Jodie A; Webster, Kate E

    2016-01-01

    To investigate the test-retest reliability of measuring hip abductor strength in patients with total knee arthroplasty (TKA) using a hand-held dynamometer (HHD) with two different types of resistance: belt and manual resistance. Test-retest reliability of 30 subjects (17 female, 13 male, 71.9 ± 7.4 years old), 9.2 ± 2.7 days post TKA was measured using belt and therapist resistance. Retest reliability was calculated with intra-class coefficients (ICC3,1) and 95% confidence intervals (CI) for both the group average and the individual scores. A paired t-test assessed whether a difference existed between the belt and therapist methods of resistance. ICCs were 0.82 and 0.80 for the belt and therapist resisted methods, respectively. Hip abductor strength increases of 8 N (14%) for belt resisted and 14 N (17%) for therapist resisted measurements of the group average exceeded the 95% CI and may represent real change. For individuals, hip abductor strength increases of 33 N (72%) (belt resisted) and 57 N (79%) (therapist resisted) could be interpreted as real change. Hip abductor strength can be reliably measured using HHD in the clinical setting with the described protocol. Belt resistance demonstrated slightly higher test-retest reliability. Reliable measurement of hip abductor muscle strength in patients with TKA is important to ensure deficiencies are addressed in rehabilitation programs and function is maximized. Hip abductor strength can be reliably measured with a hand-held dynamometer in the clinical setting using manual or belt resistance.

  11. Gap-Balancing versus Measured Resection Technique in Total Knee Arthroplasty: A Comparison Study.

    Science.gov (United States)

    Churchill, Jessica L; Khlopas, Anton; Sultan, Assem A; Harwin, Steven F; Mont, Michael A

    2018-01-01

    Proper femoral component alignment in the axial plane during total knee arthroplasty (TKA) depends on accurate bone cuts and soft tissue balancing. Two methods that are used to achieve this are "measured resection" and "gap balancing." However, a controversy exists as to which method is more accurate and leads to better outcomes. Therefore, the purpose of this study was to evaluate: (1) implant survivorship, (2) patient outcomes, (3) complications, and (4) radiographic analysis comparing patients who underwent TKA with either gap-balancing or measured resection techniques. A total of 214 consecutive patients (221 knees) underwent primary TKA by a single surgeon between 2011 and 2012. Component alignment was achieved by using measured resection in 116 knees and gap balancing was used in 105 knees. The patients had a mean age of 66 years (range, 44-86 years) and a mean body mass index of 32 kg/m 2 (range, 22-52 kg/m 2 ). Patient range-of-motion (ROM) and Knee Society (KS) function and pain scores, and radiographic assessment, were assessed preoperatively and postoperatively at ∼6 weeks, 3 months, 1 year, and then annually. The mean follow-up time was 3 years. A Kaplan-Meier's analysis was performed to calculate the survivorship. The aseptic survivorship was 98% in both the measured resection and gap-balancing groups. The mean ROM was not significantly different between the measured resection and gap-balancing groups (123 vs. 123 degrees, p  = 0.990). There were no significant differences between the two groups in terms of the KS function scores (86 vs. 85 points, p  = 0.829) or the KS pain scores (93 vs. 92 points, p  = 0.425). Otherwise, the radiographic evaluation at latest follow-up did not demonstrate any evidence of progressive radiolucencies or loosening, of any prosthesis. The results of this study found that at a mean follow-up of 3 years, both the measured resection and gap-balancing techniques achieved excellent survivorship and

  12. Triangular SPECT system for 3-D total organ volume imaging: Design concept and preliminary imaging results

    International Nuclear Information System (INIS)

    Lim, C.B.; Anderson, J.; Covic, J.

    1985-01-01

    SPECT systems based on 2-D detectors for projection data collection and filtered back-projection image reconstruction have the potential for true 3-D imaging, providing contiguous slice images in any orientation. Anger camera-based SPECT systems have the natural advantage supporting planar imaging clinical procedures. However, current systems suffer from two drawbacks; poor utilization of emitted photons, and inadequate system design for SPECT. A SPECT system consisting of three rectangular cameras with radial translation would offer the variable cylindrical FOV of 25 cm to 40 cm diameter allowing close detector access to the object. This system would provide optimized imaging for both brain and body organs in terms of sensitivity and resolution. For brain imaging a tight detector triangle with fan beam collimation, matching detector UFOV to the head, allows full 2 π utilization of emitted photons, resulting in >4 times sensitivity increase over the single detector system. Minification of intrinsic detector resolution in fan beam collimation further improves system resolution. For body organ imaging the three detectors with parallel hole collimators, rotating in non-circular orbit, provide both improved resolution and three-fold sensitivity increase. Practical challenges lie in ensuring perfect image overlap from three detectors without resolution degradation and artifact generation in order to benefit from the above improvements. An experimental system has been developed to test the above imaging concept and we have successfully demonstrated the superior image quality of the overlapped images. Design concept will be presented with preliminary imaging results

  13. Supported Mixed Oxide Catalysts for the Total Oxidation of Volatile Organic Compounds

    Czech Academy of Sciences Publication Activity Database

    Kovanda, F.; Jirátová, Květa

    2011-01-01

    Roč. 176, č. 1 (2011), s. 110-115 ISSN 0920-5861. [International Symposium on Air Pollution Abatement Catalysis (APAC) /2./. Cracow, 08.09.2010-10.09.2010] R&D Projects: GA ČR GAP106/10/1762; GA ČR GA106/09/1664 Institutional research plan: CEZ:AV0Z40720504 Keywords : layered double hydroxides * mixed oxides * ethanol total oxidation Subject RIV: CI - Industrial Chemistry, Chemical Engineering Impact factor: 3.407, year: 2011

  14. Oil flow rate measurements using 198Au and total count technique

    International Nuclear Information System (INIS)

    Goncalves, Eduardo R.; Crispim, Verginia R.

    2013-01-01

    In industrial plants, oil and oil compounds are usually transported by closed pipelines with circular cross-section. The use of radiotracers in oil transport and processing industrial facilities allows calibrating flowmeters, measuring mean residence time in cracking columns, locate points of obstruction or leak in underground ducts, as well as investigating flow behavior or industrial processes such as in distillation towers. Inspection techniques using radiotracers are non-destructive, simple, economic and highly accurate. Among them, Total Count, which uses a small amount of radiotracer with known activity, is acknowledged as an absolute technique for flow rate measurement. A viscous fluid transport system, composed by four PVC pipelines with 13m length (12m horizontal and 1m vertical) and 1/2, 3/4, 1 and 2-inch gauges, respectively, interconnected by maneuvering valves was designed and assembled in order to conduct the research. This system was used to simulate different flow conditions of petroleum compounds and for experimental studies of flow profile in the horizontal and upward directions. As 198 Au presents a single photopeak (411,8 keV), it was the radioisotope chosen for oil labeling, in small amounts (6 ml) or around 200 kBq activity, and it was injected in the oil transport lines. A NaI scintillation detector 2'x 2', with well-defined geometry, was used to measure total activity, determine the calibration factor F and, positioned after a homogenization distance and interconnected to a standardized electronic set of nuclear instrumentation modules (NIM), to detect the radioactive cloud. (author)

  15. A gravimetric method for the measurement of total spontaneous activity in rats.

    Science.gov (United States)

    Biesiadecki, B J; Brand, P H; Koch, L G; Britton, S L

    1999-10-01

    Currently available methods for the measurement of spontaneous activity of laboratory animals require expensive, specialized equipment and may not be suitable for use in low light conditions with nocturnal species. We developed a gravimetric method that uses common laboratory equipment to quantify the total spontaneous activity of rats and is suitable for use in the dark. The rat in its home cage is placed on a top-loading electronic balance interfaced to a computer. Movements are recorded by the balance as changes in weight and transmitted to the computer at 10 Hz. Data are analyzed on-line to derive the absolute value of the difference in weight between consecutive samples, and the one-second average of the absolute values is calculated. The averages are written to file for off-line analysis and summed over the desired observation period to provide a measure of total spontaneous activity. The results of in vitro experiments demonstrated that: 1) recorded weight changes were not influenced by position of the weight on the bottom of the cage, 2) values recorded from a series of weight changes were not significantly different from the calculated values, 3) the constantly decreasing force exerted by a swinging pendulum placed on the balance was accurately recorded, 4) the measurement of activity was not influenced by the evaporation of a fluid such as urine, and 5) the method can detect differences in the activity of sleeping and waking rats over a 10-min period, as well as during 4-hr intervals recorded during active (night-time) and inactive (daytime) periods. These results demonstrate that this method provides an inexpensive, accurate, and noninvasive method to quantitate the spontaneous activity of small animals.

  16. Measuring GNSS ionospheric total electron content at Concordia, and application to L-band radiometers

    Directory of Open Access Journals (Sweden)

    Vincenzo Romano

    2013-06-01

    Full Text Available In the framework of the project BIS - Bipolar Ionospheric Scintillation and Total Electron Content Monitoring, the ISACCO-DMC0 and ISACCO-DMC1 permanent monitoring stations were installed in 2008. The principal scope of the stations is to measure the ionospheric total electron content (TEC and to monitor the ionospheric scintillations, using high-sampling-frequency global positioning system (GPS ionospheric scintillation and TEC monitor (GISTM receivers. The disturbances that the ionosphere can induce on the electromagnetic signals emitted by the Global Navigation Satellite System constellations are due to the presence of electron density anomalies in the ionosphere, which are particularly frequent at high latitudes, where the upper atmosphere is highly sensitive to perturbations coming from outer space. With the development of present and future low-frequency space-borne microwave missions (e.g., Soil Moisture and Ocean Salinity [SMOS], Aquarius, and Soil Moisture Active Passive missions, there is an increasing need to estimate the effects of the ionosphere on the propagation of electromagnetic waves that affects satellite measurements. As an example, how the TEC data collected at Concordia station are useful for the calibration of the European Space Agency SMOS data within the framework of an experiment promoted by the European Space Agency (known as DOMEX will be discussed. The present report shows the ability of the GISTM station to monitor ionospheric scintillation and TEC, which indicates that only the use of continuous GPS measurements can provide accurate information on TEC variability, which is necessary for continuous calibration of satellite data.

  17. Threshold photoelectron spectroscopy and photoionization total ion yield spectroscopy of simple organic acids, aldehydes, ketones and amines

    International Nuclear Information System (INIS)

    Yencha, Andrew J; Malins, Andrew E R; Siggel-King, Michele R F; Eypper, Marie; King, George C

    2009-01-01

    We have initiated a research program to investigate the ionization behavior of some simple organic molecules containing the carboxyl group (R 2 C=O), where R could be H, OH, NH 2 , or CH 3 or other aliphatic or aromatic carbon groups, using threshold photoelectron spectroscopy and photoionization total ion yield spectroscopy. We report here on the simplest organic acid, formic acid, and two simple aldehydes: acetaldehyde and the simplest unsaturated aldehyde, 2-propenal (acrolein). The objective of this study was to characterize the valence cationic states of these molecules with vibrational structural resolution.

  18. Fetal subcutaneous tissue measurements in pregnancy as a predictor of neonatal total body composition.

    Science.gov (United States)

    O'Connor, Clare; Doolan, Anne; O'Higgins, Amy; Segurado, Ricardo; Sheridan-Pereiraet, Margaret; Turner, Michael J; Stuart, Bernard; Kennelly, Máireád M

    2014-10-01

    The purpose of this study was to examine the relationship between prenatal measures of subcutaneous tissue as surrogate markers of fetal nutritional status and correlate them with neonatal total body composition. This prospective longitudinal study of 62 singleton pregnancies obtained serial biometry and subcutaneous tissue measurements at 28, 33 and 38 weeks gestation. These measurements were then correlated with neonatal body composition, which was analysed using the PEAPOD™ Infant Body Composition System (Cosmed USA, Concord, CA, USA). At 38 weeks gestation, fetal abdominal subcutaneous tissue (FAST) in millimetres was significantly associated with infant fat mass at delivery (+64 g per mm of FAST, p < 0.001). Thigh fat (TF) at 28 weeks gestation was associated with infant fat mass at delivery (+79 g/mm TF, p = 0.023). TF at 38 weeks gestation was associated with infant fat mass (+63/mm TF, p = 0.004). TF and FAST at 38 weeks were also predictive of both birth weight and increased abdominal circumference (AC) (p = 0.001) with FAST measurement predicting an additional 5.7 mm in AC per millimetre of FAST (p = 0.002) and TF predicting an additional 6.9 mm per mm of TF (p = 0.002). We believe that this study further validates the use of prenatal measures of subcutaneous tissue and may help to highlight fetuses at risk of newborn adiposity and metabolic syndrome. © 2014 John Wiley & Sons, Ltd.

  19. Measurements of Nitrogen Dioxide Total Column Amounts using a Brewer Double Spectrophotometer in Direct Sun Mode

    Science.gov (United States)

    Cede, Alexander; Herman, Jay; Richter, Andreas; Krotkov, Nickolay; Burrows, John

    2006-01-01

    NO2 column amounts were measured for the past 2 years at Goddard Space Flight Center, Greenbelt, Maryland, using a Brewer spectrometer in direct Sun mode. A new bootstrap method to calibrate the instrument is introduced and described. This technique selects the cleanest days from the database to obtain the solar reference spectrum. The main advantage for direct Sun measurements is that the conversion uncertainty from slant column to vertical column is negligible compared to the standard scattered light observations where it is typically on the order of 100% (2sigma) at polluted sites. The total 2sigma errors of the direct Sun retrieved column amounts decrease with solar zenith angle and are estimated at 0.2 to 0.6 Dobson units (DU, 1 DU approx. equal to 2.7 10(exp 16) molecules cm(exp -2)), which is more accurate than scattered light measurements for high NO2 amounts. Measured NO2 column amounts, ranging from 0 to 3 DU with a mean of 0.7 DU, show a pronounced daily course and a strong variability from day to day. The NO2 concentration typically increases from sunrise to noon. In the afternoon it decreases in summer and stays constant in winter. As expected from the anthropogenic nature of its source, NO2 amounts on weekends are significantly reduced. The measurements were compared to satellite retrievals from Scanning Image Absorption Spectrometer for Atmospheric Chartography (SCIAMACHY). Satellite data give the same average NO2 column and show a seasonal cycle that is similar to the ground data in the afternoon. We show that NO2 must be considered when retrieving aerosol absorption properties, especially for situations with low aerosol optical depth.

  20. Key Performance Indicators to Measure Improvement After Implementation of Total Laboratory Automation Abbott Accelerator a3600.

    Science.gov (United States)

    Miler, Marijana; Nikolac Gabaj, Nora; Dukic, Lora; Simundic, Ana-Maria

    2017-12-27

    The aim of the study was to estimate improvement of work efficiency in the laboratory after implementation of total laboratory automation (TLA) by Abbott Accelerator a3600 in the laboratory with measuring different key performance indicators (KPIs) before and after TLA implementation. The objective was also to recommend steps for defining KPIs in other laboratories. For evaluation of improvement 10 organizational and/or technical KPIs were defined for all phases of laboratory work and measured before (November 2013) and after (from 2015 to 2017) TLA implementation. Out of 10 defined KPIs, 9 were successfully measured and significantly improved. Waiting time for registration of samples in the LIS was significantly reduced from 16 (9-28) to 9 (6-16) minutes after TLA (P performed at core biochemistry analyzers which significantly reduced walking distance for sample management (for more than 800 m per worker) and number of tube touches (for almost 50%). Analyzers downtime and engagement time for analyzers maintenance was reduced for 50 h and 28 h per month, respectively. TLA eliminated manual dilution of samples with extreme results with sigma values increment from 3.4 to >6 after TLA. Although median turnaround time TAT for potassium and troponin was higher (for approximately 20 min), number of outliers with TAT >60 min expressed as sigma values were satisfying (>3). Implementation of the TLA improved the most of the processes in our laboratory with 9 out of 10 properly defined and measured KPIs. With proper planning and defining of KPIs, every laboratory could measure changes in daily workflow.

  1. Measures of total stress-induced blood pressure responses are associated with vascular damage.

    Science.gov (United States)

    Nazzaro, Pietro; Seccia, Teresa; Vulpis, Vito; Schirosi, Gabriella; Serio, Gabriella; Battista, Loredana; Pirrelli, Anna

    2005-09-01

    The role of cardiovascular reactivity to study hypertension, and the assessment methods, are still controversial. We aimed to verify the association of hypertension and vascular damage with several measures of cardiovascular response. We studied 40 patients with normal-high (132 +/- 1/87 +/- 1 mm Hg) blood pressure (Group 1) and 80 untreated hypertensive subjects. Postischemic forearm vascular resistance (mFVR) served to differentiate hypertensive subjects (142 +/- 2/92 +/- 1 mm Hg v 143 +/- 2/94 +/- 2 mm Hg, P = NS) with a lower (Group 2) and higher (Group 3) hemodynamic index of vascular damage (4.8 +/- .05 v 6.3 +/- .09, P blood pressure, heart rate, forearm blood flow, and vascular resistance. Reactivity measures included: a) change from baseline, b) residualized score, c) cumulative change from baseline and residualized score, and d) total reactivity as area-under-the-curve (AUC), including changes occurring during baseline and recovery phases. The AUC of systolic blood pressure, diastolic blood pressure, and mFVR progressively increased in the groups (P AUC of SBP, DBP, and forearm blood flow and resistance demonstrated the highest (P AUC of SBP (beta = 0.634) and forearm blood flow (beta = -0.337) were predictive (P blood pressure stress response, as AUC, including baseline and recovery phases, was significantly better associated with hypertension and vascular damage than the other reactivity measures studied.

  2. Levels of total mercury in marine organisms from Adriatic Sea, Italy.

    Science.gov (United States)

    Perugini, Monia; Visciano, Pierina; Manera, Maurizio; Zaccaroni, Annalisa; Olivieri, Vincenzo; Amorena, Michele

    2009-08-01

    The presence of total mercury in fish, crustacean and cephalopod from Adriatic Sea, was investigated. The highest concentrations were observed in decreasing order in: Norway lobster (0.97 +/- 0.24 mg/kg; mean +/- SE), European hake (0.59 +/- 0.14 mg/kg), red mullet (0.48 +/- 0.09 mg/kg), blue whiting (0.38 +/- 0.09 mg/kg), Atlantic mackerel (0.36 +/- 0.08 mg/kg) and European flying squid (0.25 +/- 0.03 mg/kg). A significant difference (p fish and fishery products can exceed the maximum levels and stress the need of more information for consumers in particular for people that eat large amount of fish.

  3. Biogenic Methane Generation Potential in the Eastern Nankai Trough, Japan: Effect of Reaction Temperature and Total Organic Carbon

    Science.gov (United States)

    Aung, T. T.; Fujii, T.; Amo, M.; Suzuki, K.

    2017-12-01

    Understanding potential of methane flux from the Pleistocene fore-arc basin filled turbiditic sedimentary formation along the eastern Nankai Trough is important in the quantitative assessment of gas hydrate resources. We considered generated methane could exist in sedimentary basin in the forms of three major components, and those are methane in methane hydrate, free gas and methane dissolved in water. Generation of biomethane strongly depends on microbe activity and microbes in turn survive in diverse range of temperature, salinity and pH. This study aims to understand effect of reaction temperature and total organic carbon on generation of biomethane and its components. Biomarker analysis and cultural experiment results of the core samples from the eastern Nankai Trough reveal that methane generation rate gets peak at various temperature ranging12.5°to 35°. Simulation study of biomethane generation was made using commercial basin scale simulator, PetroMod, with different reaction temperature and total organic carbon to predict how these effect on generation of biomethane. Reaction model is set by Gaussian distribution with constant hydrogen index and standard deviation of 1. Series of simulation cases with peak reaction temperature ranging 12.5°to 35° and total organic carbon of 0.6% to 3% were conducted and analyzed. Simulation results show that linear decrease in generation potential while increasing reaction temperature. But decreasing amount becomes larger in the model with higher total organic carbon. At higher reaction temperatures, >30°, extremely low generation potential was found. This is due to the fact that the source formation modeled is less than 1 km in thickness and most of formation do not reach temperature more than 30°. In terms of the components, methane in methane hydrate and free methane increase with increasing TOC. Drastic increase in free methane was observed in the model with 3% of TOC. Methane amount dissolved in water shows almost

  4. Aortic blood flow subtraction: an alternative method for measuring total renal blood flow in conscious dogs

    DEFF Research Database (Denmark)

    Sandgaard, N C F; Andersen, J L; Holstein-Rathlou, N-H

    2002-01-01

    We have measured total renal blood flow (TRBF) as the difference between signals from ultrasound flow probes implanted around the aorta above and below the renal arteries. The repeatability of the method was investigated by repeated, continuous infusions of angiotensin II and endothelin-1 seven...... arterial blood pressure by 49% and decreased TRBF by 12%, providing an increase in renal vascular resistance of 69%. Dynamic analysis showed autoregulation of renal blood flow in the frequency range ... of TRBF by aortic blood flow subtraction is a practical and reliable method that allows direct comparison of excretory function and renal blood flow from two kidneys. The method also allows direct comparison between TRBF and flow in the caudal aorta....

  5. Measurement of fluorine total concentration in dental enamel using fast neutron activation

    International Nuclear Information System (INIS)

    Mouadili, A.; Vernais, J.; Isabelle, D.B.

    1988-01-01

    Fluorine which is present in dental enamel, at the level of a few tens to a few hundred ppm, plays an important role in the behaviour of this tissue. Therefore quantitative determination is of interest for particular studies of the dental system. We present a nuclear nondestructive method to determine the total fluorine content in dental enamel by cyclotron-produced fast-neutron activation. The 19 F(n,2n) reaction leads to 18 F which is a β + emitter with a 109.8 min half-life. The irradiated sample activity is measured by detecting in coincidence the annihilation photons. A fluorine standard is used for calibration. The detection limit is of the order of 1 ppm, while the reproducibility is better than 95% [pt

  6. Measurements of the effective total and resonance absorption cross sections for zircaloy-2 and zirconium

    Energy Technology Data Exchange (ETDEWEB)

    Kocic, A; Markovic, V [Institute of nuclear sciences Boris Kidric, Vinca, Beograd (Yugoslavia)

    1967-04-15

    Zirconium and zircaloy-2 alloy, as constructive materials, have found wide application in reactor technology, especially in heavy water systems for two reasons: a) low neutron absorption cross section, b) good mechanical properties. The thickness of the zirconium and zircaloy-2 for different applications varies from several tenths of a millimeter to about ten millimeters. Therefore, to calculate reactor systems it is desirable to know the effective neutron absorption cross section for the range of thicknesses mention above. The thermal neutron cross sections for these materials are low and no appreciable variation of the effective neutron cross section occurs even for the largest thicknesses. However, this is not true for effective resonance absorption. On the other hand, due to the lack of detailed knowledge of the zirconium resonances, calculations of the effective resonance integrals cannot be performed. Therefore it is necessary to measure the effective total and resonance absorption cross section for zirconium (author)

  7. Measuring the impact of total quality management on financial performance of croatian companies

    Directory of Open Access Journals (Sweden)

    Dubravka Pekanov Starčević

    2012-12-01

    Full Text Available Changes in the business environment have resulted in increasing the importance of the quality of products and services of a company. Insisting on quality has become a strategic goal of a company and a determiner of competitiveness both in the home and international market. The traditional approach to quality included determination of product quality after production was completed. High costs of testing to determine the quality of products and services concludes that quality assurance must be approached differently. Product controls and tests used until that moment had to be replaced with a more modern, more efficient and more effective approach known as total quality management (TQM. TQM supporters suggest that TQM implementation results in improved product quality, reduced product return, reduced costs of serving unsatisfied customers and other benefits that ultimately lead to improved financial performance of the company. This paper examines the impact of TQM imple- mentation on the financial performance of Croatian companies whose securities are traded within the regulated market. General characteristics of companies were compared in terms of (nonsystematic application of total quality management. Furthermore, the financial performance of the companies that have successfully implemented the method was measured.

  8. Measurement of total antioxidant capacity in gingival crevicular fluid and serum in dogs with periodontal disease.

    Science.gov (United States)

    Pavlica, Zlatko; Petelin, Milan; Nemec, Alenka; Erzen, Damjan; Skaleric, Uros

    2004-11-01

    To determine whether gingival crevicular fluid (GCF) and serum total antioxidant capacities (TACs) correlate with the degree of severity of periodontal disease in dogs. 41 Toy and Miniature Poodles. After assessment of the degree of severity of naturally occurring periodontitis, GCF samples from both maxillary fourth premolars and a blood sample were collected from each dog. The condition of the periodontium of the entire dentition and at each site of GCF collection was recorded. Clinical parameters assessed included plaque index, gingival index, and probing depth. Radiographic analysis of alveolar bone level was also performed. Total antioxidant capacity was measured in GCF and serum samples by use of a commercial kit. Dogs with gingivitis and minimal periodontitis had significantly higher TAC in GCF than dogs with advanced periodontitis. Bivariate regression analysis revealed significant negative correlations between TAC in GCF and clinical parameters and age. The TAC in serum was significantly negatively correlated with the degree of gingival inflammation but was not significantly correlated with age. TAC in GCF is related to the degree of severity of periodontal disease in dogs. This is likely the result of release of reactive oxygen species by activated phagocytes and fibroblasts in the inflamed periodontal tissues. The results of our study suggest that the local delivery of antioxidants may be a useful adjunctive treatment for periodontitis in dogs.

  9. Ultrasound-assisted extraction for total sulphur measurement in mine tailings

    International Nuclear Information System (INIS)

    Khan, Adnan Hossain; Shang, Julie Q.; Alam, Raquibul

    2012-01-01

    Highlights: ► We develop a total sulphur measuring procedure of mine tailings. ► Ultrasound is used in the sample pre-treatment process. ► Full factorial design is applied to identify the best level of effecting factors. - Abstract: A sample preparation method for percentage recovery of total sulphur (%S) in reactive mine tailings based on ultrasound-assisted digestion (USAD) and inductively coupled plasma-optical emission spectroscopy (ICP-OES) was developed. The influence of various methodological factors was screened by employing a two-level and three-factor (2 3 ) full factorial design and using KZK-1, a sericite schist certified reference material (CRM), to find the optimal combination of studied factors and %S. Factors such as the sonication time, temperature and acid combination were studied, with the best result identified as 20 min of sonication, 80 °C temperature and 1 ml of HNO 3 :1 ml of HCl, which can achieve 100% recovery for the selected CRM. Subsequently a fraction of the 2 3 full factorial design was applied to mine tailings. The percentage relative standard deviation (%RSD) for the ultrasound method is less than 3.0% for CRM and less than 6% for the mine tailings. The investigated method was verified by X-ray diffraction analysis. The USAD method compared favorably with existing methods such as hot plate assisted digestion method, X-ray fluorescence and LECO™-CNS method.

  10. New method to determine the total carbonyl functional group content in extractable particulate organic matter by tandem mass spectrometry.

    Science.gov (United States)

    Dron, J; Zheng, W; Marchand, N; Wortham, H

    2008-08-01

    A functional group analysis method was developed to determine the quantitative content of carbonyl functional groups in atmospheric particulate organic matter (POM) using constant neutral loss scanning-tandem mass spectrometry (CNLS-MS/MS). The neutral loss method consists in monitoring the loss of a neutral fragment produced by the fragmentation of a precursor ion in a collision cell. The only ions detected are the daughter ions resulting from the loss of the neutral fragment under study. Then, scanning the loss of a neutral fragment characteristic of a functional group enables the selective detection of the compounds bearing the chemical function under study within a complex mixture. The selective detection of carbonyl functional groups was achieved after derivatization with pentafluorophenylhydrazine (PFPH) by monitoring the neutral loss of C(6)F(5)N (181 amu), which was characteristic of a large panel of derivatized carbonyl compounds. The method was tested on 25 reference mixtures of different composition, all containing 24 carbonyl compounds at randomly determined concentrations. The repeatability and calibration tests were satisfying as they resulted in a relative standard deviation below 5% and a linear range between 0.01 and 0.65 mM with a calculated detection limit of 0.0035 mM. Also, the relative deviation induced by changing the composition of the mixture while keeping the total concentration of carbonyl functional groups constant was less than 20%. These reliability experiments demonstrate the high robustness of the developed procedure for accurate carbonyl functional group measurement, which was applied to atmospheric POM samples. Copyright (c) 2008 John Wiley & Sons, Ltd.

  11. Flow-injection determination of total organic fluorine with off-line defluorination reaction on a solid sorbent bed.

    Science.gov (United States)

    Musijowski, Jacek; Trojanowicz, Marek; Szostek, Bogdan; da Costa Lima, José Luis Fontes; Lapa, Rui; Yamashita, Hiroki; Takayanagi, Toshio; Motomizu, Shoji

    2007-09-26

    Considering recent reports on widespread occurrence and concerns about perfluoroalkyl substances (PFAS) in environmental and biological systems, analysis of these compounds have gained much attention in recent years. Majority of analyte-specific methods are based on a LC/MS/MS or a GC/MS detection, however many environmental or biological studies would benefit from a total organic fluorine (TOF) determination. Presented work was aimed at developing a method for TOF determination. TOF is determined as an amount of inorganic fluoride obtained after defluorination reaction conducted off-line using sodium biphenyl reagent directly on the sorbent without elution of retained analytes. Recovered fluoride was analyzed using flow-injection system with either fluorimetric or potentiometric detection. The TOF method was tested using perfluorocarboxylic acids (PFCA), including perfluorooctanoic acid (PFOA), as model compounds. Considering low concentrations of PFAS in natural samples, solid-phase extraction as a preconcentration procedure was evaluated. Several carbon-based sorbents were tested, namely multi-wall carbon nanotubes, carbon nanofibres and activated carbon. Good sorption of all analytes was achieved and defluorination reaction was possible to carry out directly on a sorbent bed. Recoveries obtained for PFCAs, adsorbed on an activated carbon sorbent, and measured as TOF, were 99.5+/-1.7, 110+/-9.4, 95+/-26, 120+/-32, 110+/-12 for C4, C6, C8, C10 and C12-PFCA, respectively. Two flow systems that would enable the defluorination reaction and fluoride determination in a single system were designed and tested.

  12. The Total Deviation Index estimated by Tolerance Intervals to evaluate the concordance of measurement devices

    Directory of Open Access Journals (Sweden)

    Ascaso Carlos

    2010-04-01

    Full Text Available Abstract Background In an agreement assay, it is of interest to evaluate the degree of agreement between the different methods (devices, instruments or observers used to measure the same characteristic. We propose in this study a technical simplification for inference about the total deviation index (TDI estimate to assess agreement between two devices of normally-distributed measurements and describe its utility to evaluate inter- and intra-rater agreement if more than one reading per subject is available for each device. Methods We propose to estimate the TDI by constructing a probability interval of the difference in paired measurements between devices, and thereafter, we derive a tolerance interval (TI procedure as a natural way to make inferences about probability limit estimates. We also describe how the proposed method can be used to compute bounds of the coverage probability. Results The approach is illustrated in a real case example where the agreement between two instruments, a handle mercury sphygmomanometer device and an OMRON 711 automatic device, is assessed in a sample of 384 subjects where measures of systolic blood pressure were taken twice by each device. A simulation study procedure is implemented to evaluate and compare the accuracy of the approach to two already established methods, showing that the TI approximation produces accurate empirical confidence levels which are reasonably close to the nominal confidence level. Conclusions The method proposed is straightforward since the TDI estimate is derived directly from a probability interval of a normally-distributed variable in its original scale, without further transformations. Thereafter, a natural way of making inferences about this estimate is to derive the appropriate TI. Constructions of TI based on normal populations are implemented in most standard statistical packages, thus making it simpler for any practitioner to implement our proposal to assess agreement.

  13. Impact of total organic carbon (in sediments) and dissolved organic carbon (in overlying water column) on Hg sequestration by coastal sediments from the central east coast of India

    Digital Repository Service at National Institute of Oceanography (India)

    Chakrabortya, P.; Sharma, B.M.; Babu, P.V.R.; Yao, K.M.; Jaychandran, S.

    , 1991; Liu et al., 2006; Tack and Verloo, 1995). Mercury accumulates in sediment globally from many physical, chemical, biological, geological and anthropogenic environmental processes. Thus, sediment can be a good indicator of water quality of a...-Black method (Schumacher, 2002). This method has been widely used for the determination of total organic carbon in the soil and sediments. 3.0 Results and discussion The general description and texture analysis of the studied sediments are presented...

  14. Direct measurement of the total decay width of the top quark.

    Science.gov (United States)

    Aaltonen, T; Amerio, S; Amidei, D; Anastassov, A; Annovi, A; Antos, J; Apollinari, G; Appel, J A; Arisawa, T; Artikov, A; Asaadi, J; Ashmanskas, W; Auerbach, B; Aurisano, A; Azfar, F; Badgett, W; Bae, T; Barbaro-Galtieri, A; Barnes, V E; Barnett, B A; Barria, P; Bartos, P; Bauce, M; Bedeschi, F; Behari, S; Bellettini, G; Bellinger, J; Benjamin, D; Beretvas, A; Bhatti, A; Bland, K R; Blumenfeld, B; Bocci, A; Bodek, A; Bortoletto, D; Boudreau, J; Boveia, A; Brigliadori, L; Bromberg, C; Brucken, E; Budagov, J; Budd, H S; Burkett, K; Busetto, G; Bussey, P; Butti, P; Buzatu, A; Calamba, A; Camarda, S; Campanelli, M; Canelli, F; Carls, B; Carlsmith, D; Carosi, R; Carrillo, S; Casal, B; Casarsa, M; Castro, A; Catastini, P; Cauz, D; Cavaliere, V; Cavalli-Sforza, M; Cerri, A; Cerrito, L; Chen, Y C; Chertok, M; Chiarelli, G; Chlachidze, G; Cho, K; Chokheli, D; Clark, A; Clarke, C; Convery, M E; Conway, J; Corbo, M; Cordelli, M; Cox, C A; Cox, D J; Cremonesi, M; Cruz, D; Cuevas, J; Culbertson, R; d'Ascenzo, N; Datta, M; de Barbaro, P; Demortier, L; Deninno, M; D'Errico, M; Devoto, F; Di Canto, A; Di Ruzza, B; Dittmann, J R; Donati, S; D'Onofrio, M; Dorigo, M; Driutti, A; Ebina, K; Edgar, R; Elagin, A; Erbacher, R; Errede, S; Esham, B; Farrington, S; Fernández Ramos, J P; Field, R; Flanagan, G; Forrest, R; Franklin, M; Freeman, J C; Frisch, H; Funakoshi, Y; Galloni, C; Garfinkel, A F; Garosi, P; Gerberich, H; Gerchtein, E; Giagu, S; Giakoumopoulou, V; Gibson, K; Ginsburg, C M; Giokaris, N; Giromini, P; Giurgiu, G; Glagolev, V; Glenzinski, D; Gold, M; Goldin, D; Golossanov, A; Gomez, G; Gomez-Ceballos, G; Goncharov, M; González López, O; Gorelov, I; Goshaw, A T; Goulianos, K; Gramellini, E; Grinstein, S; Grosso-Pilcher, C; Group, R C; Guimaraes da Costa, J; Hahn, S R; Han, J Y; Happacher, F; Hara, K; Hare, M; Harr, R F; Harrington-Taber, T; Hatakeyama, K; Hays, C; Heinrich, J; Herndon, M; Hocker, A; Hong, Z; Hopkins, W; Hou, S; Hughes, R E; Husemann, U; Hussein, M; Huston, J; Introzzi, G; Iori, M; Ivanov, A; James, E; Jang, D; Jayatilaka, B; Jeon, E J; Jindariani, S; Jones, M; Joo, K K; Jun, S Y; Junk, T R; Kambeitz, M; Kamon, T; Karchin, P E; Kasmi, A; Kato, Y; Ketchum, W; Keung, J; Kilminster, B; Kim, D H; Kim, H S; Kim, J E; Kim, M J; Kim, S H; Kim, S B; Kim, Y J; Kim, Y K; Kimura, N; Kirby, M; Knoepfel, K; Kondo, K; Kong, D J; Konigsberg, J; Kotwal, A V; Kreps, M; Kroll, J; Kruse, M; Kuhr, T; Kurata, M; Laasanen, A T; Lammel, S; Lancaster, M; Lannon, K; Latino, G; Lee, H S; Lee, J S; Leo, S; Leone, S; Lewis, J D; Limosani, A; Lipeles, E; Lister, A; Liu, H; Liu, Q; Liu, T; Lockwitz, S; Loginov, A; Lucchesi, D; Lucà, A; Lueck, J; Lujan, P; Lukens, P; Lungu, G; Lys, J; Lysak, R; Madrak, R; Maestro, P; Malik, S; Manca, G; Manousakis-Katsikakis, A; Marchese, L; Margaroli, F; Marino, P; Martínez, M; Matera, K; Mattson, M E; Mazzacane, A; Mazzanti, P; McNulty, R; Mehta, A; Mehtala, P; Mesropian, C; Miao, T; Mietlicki, D; Mitra, A; Miyake, H; Moed, S; Moggi, N; Moon, C S; Moore, R; Morello, M J; Mukherjee, A; Muller, Th; Murat, P; Mussini, M; Nachtman, J; Nagai, Y; Naganoma, J; Nakano, I; Napier, A; Nett, J; Neu, C; Nigmanov, T; Nodulman, L; Noh, S Y; Norniella, O; Oakes, L; Oh, S H; Oh, Y D; Oksuzian, I; Okusawa, T; Orava, R; Ortolan, L; Pagliarone, C; Palencia, E; Palni, P; Papadimitriou, V; Parker, W; Pauletta, G; Paulini, M; Paus, C; Phillips, T J; Piacentino, G; Pianori, E; Pilot, J; Pitts, K; Plager, C; Pondrom, L; Poprocki, S; Potamianos, K; Pranko, A; Prokoshin, F; Ptohos, F; Punzi, G; Ranjan, N; Redondo Fernández, I; Renton, P; Rescigno, M; Rimondi, F; Ristori, L; Robson, A; Rodriguez, T; Rolli, S; Ronzani, M; Roser, R; Rosner, J L; Ruffini, F; Ruiz, A; Russ, J; Rusu, V; Sakumoto, W K; Sakurai, Y; Santi, L; Sato, K; Saveliev, V; Savoy-Navarro, A; Schlabach, P; Schmidt, E E; Schwarz, T; Scodellaro, L; Scuri, F; Seidel, S; Seiya, Y; Semenov, A; Sforza, F; Shalhout, S Z; Shears, T; Shepard, P F; Shimojima, M; Shochet, M; Shreyber-Tecker, I; Simonenko, A; Sliwa, K; Smith, J R; Snider, F D; Song, H; Sorin, V; St Denis, R; Stancari, M; Stentz, D; Strologas, J; Sudo, Y; Sukhanov, A; Suslov, I; Takemasa, K; Takeuchi, Y; Tang, J; Tecchio, M; Teng, P K; Thom, J; Thomson, E; Thukral, V; Toback, D; Tokar, S; Tollefson, K; Tomura, T; Tonelli, D; Torre, S; Torretta, D; Totaro, P; Trovato, M; Ukegawa, F; Uozumi, S; Vázquez, F; Velev, G; Vellidis, C; Vernieri, C; Vidal, M; Vilar, R; Vizán, J; Vogel, M; Volpi, G; Wagner, P; Wallny, R; Wang, S M; Waters, D; Wester, W C; Whiteson, D; Wicklund, A B; Wilbur, S; Williams, H H; Wilson, J S; Wilson, P; Winer, B L; Wittich, P; Wolbers, S; Wolfe, H; Wright, T; Wu, X; Wu, Z; Yamamoto, K; Yamato, D; Yang, T; Yang, U K; Yang, Y C; Yao, W-M; Yeh, G P; Yi, K; Yoh, J; Yorita, K; Yoshida, T; Yu, G B; Yu, I; Zanetti, A M; Zeng, Y; Zhou, C; Zucchelli, S

    2013-11-15

    We present a measurement of the total decay width of the top quark using events with top-antitop quark pair candidates reconstructed in the final state with one charged lepton and four or more hadronic jets. We use the full Tevatron run II data set of sqrt[s]=1.96  TeV proton-antiproton collisions recorded by the CDF II detector. The top quark mass and the mass of the hadronically decaying W boson are reconstructed for each event and compared with distributions derived from simulated signal and background samples to extract the top quark width (Γtop) and the energy scale of the calorimeter jets with in situ calibration. For a top quark mass Mtop=172.5  GeV/c2, we find 1.10<Γtop<4.05  GeV at 68% confidence level, which is in agreement with the standard model expectation of 1.3 GeV and is the most precise direct measurement of the top quark width to date.

  15. A new method for the measurement of anteversion of the acetabular cup after total hip arthroplasty.

    Science.gov (United States)

    Aydogan, Mehmet; Burç, Halil; Saka, Gursel

    2014-08-01

    Many methods of determining the anteversion of the acetabular cup have been described in the literature. The advantages and disadvantages of each of these methods are discussed in this paper. We present a new method of measuring the acetabular anteversion at the anteroposterior hip. The formula designed by the authors was anteversion angle (α) = arc sin |PK|/√ |AK| × |BK|. The formula was tested using the AutoCAD software, and an experimental study was conducted to evaluate the accuracy. Three groups were created, and 16 X-ray images were taken and coded. Ten orthopaedic surgeons measured the acetabular anteversion from these X-rays using our formula. The results in Group 1 were closer to the actual value; in contrast, the results in Group 2 differed from the actual values. The results in Group 3 were as close to the actual anteversion values as were those in Group 1. Developments in technology often bring an increase in complications. Despite newly developed surgical methods and technology, the position of the acetabular cup is still used to determine the results of a total hip arthroplasty. Our method is simple, cost-effective and achieves almost 100 % accuracy.

  16. Measurement of total phospholipids in urine of patients treated with gentamicin.

    Science.gov (United States)

    Saunders, D A; Begg, E J; Kirkpatrick, C M; Yeo, J; Graham, G G; Bailey, R R

    1997-04-01

    The excretion of phospholipids in urine may be a marker of the early renal toxicity of the aminoglycoside antibiotics. Urinary phospholipids are formed in myeloid bodies which develop in the lysosomes of proximal tubules during treatment with the aminoglycosides, and overflow into the urine. Published assays were modified in order to measure the total phospholipid concentrations in human urine. Phospholipids were extracted from freeze-dried urine samples, digested in concentrated sulphuric acid, and the inorganic phosphorus content determined by complexing with ammonium molybdate and measuring the absorbance at 820 nm. Ten septicaemic patients treated with gentamicin for 5-7 days had significantly higher urine phospholipid concentrations than 10 healthy untreated control subjects (P < 0.0001). There was a negative linear relationship between phospholipid excretion and creatinine clearance (r2 = 0.71). In 34 patients with acute pyelonephritis, increased phospholipid concentrations were observed prior to treatment compared with healthy controls (P < 0.001) and did not alter during treatment with gentamicin. However, the phospholipid concentrations decreased significantly after treatment was completed (P < 0.03). These studies suggest that urinary phospholipids may indicate early aminoglycoside toxicity but with poor specificity, as many of the infections being treated may themselves be associated with phospholipiduria.

  17. Status report and measurement of total cross-sections at the Pohang Neutron Facility

    International Nuclear Information System (INIS)

    Kim, G.N.; Meaze, A.K.M.M.H.; Ahmed, H.

    2004-01-01

    We report the status of the Pohang Neutron Facility which consists of an electron linear accelerator, a water-cooled Ta target, and an 11-m time-of-flight path. It has been equipped with a four-position sample changer controlled remotely by a CAMAC data acquisition system, which allows simultaneous accumulation of the neutron time of flight spectra from 4 different detectors. It is possible to measure the neutron total cross-sections in the neutron energy range from 0.1 eV to 100 eV by using the neutron time of flight method. A 6 LiZnS(Ag) glass scintillator was used as a neutron detector. The neutron flight path from the water-cooled Ta target to the neutron detector was 10.81±0.02 m. The background level was determined by using notch-filters of Co, In, Ta, and Cd sheets. In order to reduce the gamma rays from Bremsstrahlung and those from neutron capture, we employed a neutron-gamma separation system based on their different pulse shapes. The present measurements are in general agreement with the evaluated data in ENDF/B-VI. The resonance parameters were extracted from the transmission data from the SAMMY fitting and compared with the previous ones. (author)

  18. Cantilever contribution to the total electrostatic force measured with the atomic force microscope

    International Nuclear Information System (INIS)

    Guriyanova, Svetlana; Golovko, Dmytro S; Bonaccurso, Elmar

    2010-01-01

    The atomic force microscope (AFM) is a powerful tool for surface imaging at the nanometer scale and surface force measurements in the piconewton range. Among long-range surface forces, the electrostatic forces play a predominant role. They originate if the electric potentials of the substrate and of the tip of the AFM cantilever are different. A quantitative interpretation of the AFM signal is often difficult because it depends in a complicated fashion on the cantilever–tip–surface geometry. Since the electrostatic interaction is a long-range interaction, the cantilever, which is many microns from the surface, contributes to the total electrostatic force along with the tip. Here we present results of the electrostatic interaction between a conducting flat surface and horizontal or tilted cantilevers, with and without tips, at various distances from the surface. As addressed in a previous work, we show that the contribution of the cantilever to the overall force cannot be neglected. Based on a predictive model and on 3D confocal measurements, we discuss the influence of the tilting angle of the cantilever

  19. Measuring Total Column Water Vapor by Pointing an Infrared Thermometer at the Sky

    Science.gov (United States)

    Mims, Forrest M., III; Chambers, Lin H.; Brooks, David R.

    2011-01-01

    A 2-year study affirms that the temperature (Tz) indicated by an inexpensive ($20 to $60) IR thermometer pointed at the cloud-free zenith sky provides an approximate indication of the total column water vapor (precipitable water or PW). PW was measured by a MICROTOPS II sun photometer. The coefficient of correlation (r2) of the PW and Tz was 0.90, and the rms difference was 3.2 mm. A comparison of the Tz data with the PW provided by a GPS site 31 km NNE yielded an r2 of 0.79, and an rms difference of 5.8 mm. An expanded study compared Tz from eight IR thermometers with PW at various times during the day and night from 17 May to 18 October 2010, mainly at the Texas site and 10 days at Hawaii's Mauna Loa Observatory (MLO). The best results of this comparison were provided by two IR thermometers models that yielded an r2 of 0.96 and an rms difference with the PW of 2.7 mm. The results of both the ongoing 2-year study and the 5-month instrument comparison show that IR thermometers can measure PW with an accuracy (rms difference/mean PW) approaching 10%, the accuracy typically ascribed to sun photometers.

  20. TRANC - a novel fast-response converter to measure total reactive atmospheric nitrogen

    Science.gov (United States)

    Marx, O.; Brümmer, C.; Ammann, C.; Wolff, V.; Freibauer, A.

    2012-05-01

    The input and loss of plant available nitrogen (reactive nitrogen: Nr) from/to the atmosphere can be an important factor for the productivity of ecosystems and thus for its carbon and greenhouse gas exchange. We present a novel converter for reactive nitrogen (TRANC: Total Reactive Atmospheric Nitrogen Converter), which offers the opportunity to quantify the sum of all airborne reactive nitrogen compounds (∑Nr) in high time resolution. The basic concept of the TRANC is the full conversion of all Nr to nitrogen monoxide (NO) within two reaction steps. Initially, reduced Nr compounds are being oxidised, and oxidised Nr compounds are thermally converted to lower oxidation states. Particulate Nr is being sublimated and oxidised or reduced afterwards. In a second step, remaining higher nitrogen oxides or those generated in the first step are catalytically converted to NO with carbon monoxide used as reduction gas. The converter is combined with a fast response chemiluminescence detector (CLD) for NO analysis and its performance was tested for the most relevant gaseous and particulate Nr species under both laboratory and field conditions. Recovery rates during laboratory tests for NH3 and NO2 were found to be 95 and 99%, respectively, and 97% when the two gases were combined. In-field longterm stability over an 11-month period was approved by a value of 91% for NO2. Effective conversion was also found for ammonium and nitrate containing particles. The recovery rate of total ambient Nr was tested against the sum of individual measurements of NH3, HNO3, HONO, NH4+, NO3-, and NOx using a combination of different well-established devices. The results show that the TRANC-CLD system precisely captures fluctuations in ∑Nr concentrations and also matches the sum of all individual Nr compounds measured by the different single techniques. The TRANC features a specific design with very short distance between the sample air inlet and the place where the thermal and catalytic

  1. TRANC – a novel fast-response converter to measure total reactive atmospheric nitrogen

    Directory of Open Access Journals (Sweden)

    V. Wolff

    2012-05-01

    Full Text Available The input and loss of plant available nitrogen (reactive nitrogen: Nr from/to the atmosphere can be an important factor for the productivity of ecosystems and thus for its carbon and greenhouse gas exchange. We present a novel converter for reactive nitrogen (TRANC: Total Reactive Atmospheric Nitrogen Converter, which offers the opportunity to quantify the sum of all airborne reactive nitrogen compounds (∑Nr in high time resolution. The basic concept of the TRANC is the full conversion of all Nr to nitrogen monoxide (NO within two reaction steps. Initially, reduced Nr compounds are being oxidised, and oxidised Nr compounds are thermally converted to lower oxidation states. Particulate Nr is being sublimated and oxidised or reduced afterwards. In a second step, remaining higher nitrogen oxides or those generated in the first step are catalytically converted to NO with carbon monoxide used as reduction gas. The converter is combined with a fast response chemiluminescence detector (CLD for NO analysis and its performance was tested for the most relevant gaseous and particulate Nr species under both laboratory and field conditions. Recovery rates during laboratory tests for NH3 and NO2 were found to be 95 and 99%, respectively, and 97% when the two gases were combined. In-field longterm stability over an 11-month period was approved by a value of 91% for NO2. Effective conversion was also found for ammonium and nitrate containing particles. The recovery rate of total ambient Nr was tested against the sum of individual measurements of NH3, HNO3, HONO, NH4+, NO3−, and NOx using a combination of different well-established devices. The results show that the TRANC-CLD system precisely captures fluctuations in ∑Nr concentrations and also matches the sum of all individual Nr compounds measured by the different single techniques. The TRANC features a specific design with very short distance between the sample air inlet and the place where the thermal

  2. Diffusivity measurements of volatile organics in levitated viscous aerosol particles

    Directory of Open Access Journals (Sweden)

    S. Bastelberger

    2017-07-01

    Full Text Available Field measurements indicating that atmospheric secondary organic aerosol (SOA particles can be present in a highly viscous, glassy state have spurred numerous studies addressing low diffusivities of water in glassy aerosols. The focus of these studies is on kinetic limitations of hygroscopic growth and the plasticizing effect of water. In contrast, much less is known about diffusion limitations of organic molecules and oxidants in viscous matrices. These may affect atmospheric chemistry and gas–particle partitioning of complex mixtures with constituents of different volatility. In this study, we quantify the diffusivity of a volatile organic in a viscous matrix. Evaporation of single particles generated from an aqueous solution of sucrose and small amounts of volatile tetraethylene glycol (PEG-4 is investigated in an electrodynamic balance at controlled relative humidity (RH and temperature. The evaporative loss of PEG-4 as determined by Mie resonance spectroscopy is used in conjunction with a radially resolved diffusion model to retrieve translational diffusion coefficients of PEG-4. Comparison of the experimentally derived diffusivities with viscosity estimates for the ternary system reveals a breakdown of the Stokes–Einstein relationship, which has often been invoked to infer diffusivity from viscosity. The evaporation of PEG-4 shows pronounced RH and temperature dependencies and is severely depressed for RH ≲ 30 %, corresponding to diffusivities < 10−14 cm2 s−1 at temperatures < 15 °C. The temperature dependence is strong, suggesting a diffusion activation energy of about 300 kJ mol−1. We conclude that atmospheric volatile organic compounds can be subject to severe diffusion limitations in viscous organic aerosol particles. This may enable an important long-range transport mechanism for organic material, including pollutant molecules such as polycyclic aromatic hydrocarbons (PAHs.

  3. Natural Product Total Synthesis in the Organic Laboratory: Total Synthesis of Caffeic Acid Phenethyl Ester (CAPE), a Potent 5-Lipoxygenase Inhibitor from Honeybee Hives

    Science.gov (United States)

    Touaibia, Mohamed; Guay, Michel

    2011-01-01

    Natural products play a critical role in modern organic synthesis and learning synthetic techniques is an important component of the organic laboratory experience. In addition to traditional one-step organic synthesis laboratories, a multistep natural product synthesis is an interesting experiment to challenge students. The proposed three-step…

  4. The Impact of Imaging Modality on the Measurement of Coronal Plane Alignment After Total Knee Arthroplasty.

    Science.gov (United States)

    Nam, Denis; Vajapey, Sravya; Nunley, Ryan M; Barrack, Robert L

    2016-10-01

    The optimal coronal alignment after total knee arthroplasty (TKA) has become an area of increased debate. Sources of variability among investigations include the radiographic technique used for both preoperative surgical planning and postoperative alignment assessments. This study's purpose was to assess the impact of the imaging modality used on the measurement of coronal plane alignment after TKA. A consecutive series of patients undergoing TKA using the same cruciate-retaining prosthesis were included for analysis. Postoperatively, all patients received both a rotationally controlled, scout computed tomography scan and a hip-knee-ankle (HKA) image using the EOS Imaging system (EOS Inc., Paris, France). Two, independent observers measured the HKA angle, and femoral and tibial component alignment from each image. After classifying overall and component alignment as neutral, varus, or valgus, 40.6% (65 of 160) of knees had a discordant alignment classification for HKA, 28.1% (45 of 160) for femoral component alignment, and 26.9% (43 of 160) for tibial component alignment between their computed tomography and EOS images. Overall, 24.4% (39 of 160) of patients had a HKA difference of ≥3° between the 2 images, whereas 18.8% (30 of 160) and 20.0% (32 of 160) of patients had a femoral and tibial component alignment difference of ≥2°, respectively. Significant differences are present when comparing 2 measurement techniques of mechanical alignment after TKA. The impact of imaging modality on postoperative assessments must be accounted for and be consistent when comparing the results of different investigations. Copyright © 2016 Elsevier Inc. All rights reserved.

  5. Contribution of transformation products towards the total herbicide toxicity to tropical marine organisms.

    Science.gov (United States)

    Mercurio, Philip; Eaglesham, Geoff; Parks, Stephen; Kenway, Matt; Beltran, Victor; Flores, Florita; Mueller, Jochen F; Negri, Andrew P

    2018-03-19

    The toxicity of herbicide degradation (transformation) products is rarely taken into account, even though these are commonly detected in the marine environment, sometimes at concentrations higher than the parent compounds. Here we assessed the potential contribution of toxicity by transformation products of five photosystem II herbicides to coral symbionts (Symbiodinium sp.), the green algae Dunaliella sp., and prawn (Penaeus monodon) larvae. Concentration-dependent inhibition of photosynthetic efficiency (∆F/F m ') was observed for all herbicides in both microalgal species. The toxicity of solutions of aged diuron solutions containing transformation products to Symbiodinium sp. and Dunaliella sp. was greater than could be explained by the concentrations of diuron measured, indicating transformation products contributed to the inhibition of ∆F/F m '. However, the toxicity of aged atrazine, simazine, hexazinone, and ametryn solutions could be explained by the concentration of parent herbicide, indicating no contribution by transformation products. Prawn larval metamorphosis was not sensitive to the herbicides, but preliminary results indicated some toxicity of the transformation products of atrazine and diuron. Risk assessments should take into account the contribution of herbicide transformation products; however, further studies are clearly needed to test the toxicity of a far wider range of transformation products to a representative diversity of relevant taxa.

  6. Ultrasound-assisted extraction for total sulphur measurement in mine tailings

    Energy Technology Data Exchange (ETDEWEB)

    Khan, Adnan Hossain, E-mail: ad_li2@yahoo.com [Department of Civil and Environmental Engineering, University of Western Ontario (Canada); Shang, Julie Q.; Alam, Raquibul [Department of Civil and Environmental Engineering, University of Western Ontario (Canada)

    2012-10-15

    Highlights: Black-Right-Pointing-Pointer We develop a total sulphur measuring procedure of mine tailings. Black-Right-Pointing-Pointer Ultrasound is used in the sample pre-treatment process. Black-Right-Pointing-Pointer Full factorial design is applied to identify the best level of effecting factors. - Abstract: A sample preparation method for percentage recovery of total sulphur (%S) in reactive mine tailings based on ultrasound-assisted digestion (USAD) and inductively coupled plasma-optical emission spectroscopy (ICP-OES) was developed. The influence of various methodological factors was screened by employing a two-level and three-factor (2{sup 3}) full factorial design and using KZK-1, a sericite schist certified reference material (CRM), to find the optimal combination of studied factors and %S. Factors such as the sonication time, temperature and acid combination were studied, with the best result identified as 20 min of sonication, 80 Degree-Sign C temperature and 1 ml of HNO{sub 3}:1 ml of HCl, which can achieve 100% recovery for the selected CRM. Subsequently a fraction of the 2{sup 3} full factorial design was applied to mine tailings. The percentage relative standard deviation (%RSD) for the ultrasound method is less than 3.0% for CRM and less than 6% for the mine tailings. The investigated method was verified by X-ray diffraction analysis. The USAD method compared favorably with existing methods such as hot plate assisted digestion method, X-ray fluorescence and LECO Trade-Mark-Sign -CNS method.

  7. Isocyanate and total inhalable particulate air measurements in the European wood panel industry.

    Science.gov (United States)

    Vangronsveld, E; Berckmans, S; Verbinnen, K; Van Leeuw, C; Bormans, C

    2010-11-01

    It is well known that the use of MDI (methylene diphenyldiisocyanate) as an alternative for formaldehyde-based resins is seen as a responsible option to reduce formaldehyde emissions for CWP (Composite Wood Products) in buildings. However, there are concerns raised regarding the exposure risk of workers. The purpose of this article is to provide the reader with factual information to demonstrate that the use of MDI compared to other agents used in CWP production processes does not pose increased inhalation exposure risks for workers. Personal and area air measurements were carried out at nine Composite Wood Panel plants throughout Europe to assess potential inhalation exposures to MDI and wood dust as Total Inhalable Particulates (TIP). In total, 446 pairs of samples were collected for MDI and TIP of which 283 pairs were personal samples and the remaining 163 pairs were area samples collected at key locations along the production line. This data together with published formaldehyde exposure data has been used to evaluate the exposure safety margin opposite what are considered relevant occupational exposure limits. The methods used for sampling and analysing MDI and TIP are based on internationally accepted methods, i.e. MDHS 25/3 (or ISO 16702) for MDI, and MDHS 14/3 for TIP. The job functions with an increased exposure profile for TIP were the cleaners, drying operators and quality control staff, and for MDI, the cleaners and quality control staff. The areas with an increased exposure profile for TIP are the conveyor area from OSB blender to former area and the OSB press infeed, and for MDI the OSB weigh belt and OSB former bin area. The exposure safety margin opposite the selected exposure limits can be ranked as MDI>TIP>formaldehyde (high margin of safety to low margin of safety), indicating that the use of MDI also reduces the exposure risks to workers during production of CWP compared to formaldehyde. By reducing the airborne TIP concentrations, a respiratory

  8. Exposure to Inhalable Dust, Endotoxin, and Total Volatile Organic Carbons on Dairy Farms Using Manual and Automated Feeding Systems

    DEFF Research Database (Denmark)

    Basinas, Ioannis; Cronin, Garvin; Hogan, Victoria

    2017-01-01

    Introduction: Agricultural workers tend to have high exposures to organic dusts which may induce or exacerbate respiratory disorders. Studies investigating the effect of work tasks and farm characteristics on organic dust exposures among farm workers suggest that handling of animal feed is an imp...... feeding. Until effective permanent engineering controls are established farm workers should be encouraged to wear respiratory protective equipment during these tasks....... of exposure to these agents depend on the applied feeding system in the farms. Methods: Thirty-eight personal exposure measurements were collected from farmers across seven dairy farms. The farms used manual, loft, or semi-automated feeding systems. Information on worker tasks and farm characteristics...

  9. Distribution of Total and Organic Mercury in Superficial Soils in the Upper Manzanares River Watershed, Sucre State, Venezuela

    Directory of Open Access Journals (Sweden)

    Yahsé Rojas Challa

    2008-01-01

    Full Text Available Total and organic mercury contents were determined from samples of surface soils (0-5 cm, sieved at ≤ 63µm, collected from 10 different locations in the upper Manzanares River watershed, using cold vapor atomic absorption spectroscopy. Methylmercury was determined using a HPLC-UV detector. The mean total mercury concentration was 1.3 μg.g-1, a value permitted by the Canadian environment quality guidelines for farming soils, but high for European standards. Using certified reference materials, we verified that a modification of the method described by Qian et al. (2000 was effective for organic mercury extraction, with a recovery of 92.17% for DORM-2 and 92.11% for TORT-2. This modified method was applied to soil samples, obtaining concentrations of 0.5-1.0 μg.g-1 of organic mercury. The parameters for determining methylmercury using HPLC-UV were optimized; the best results were obtained with a 4.6 mm x 25 cm Zorbax CN column, with a mobile phase of 70/30 V/V of methanol: ammonium acetate 0.05 mol.l-1, with a flow rate of 0.5 ml.min-1; the methylmercury was detected at 4.99 min retention time. Methylmercury was not found in the soil samples. Using the certified reference material we proved that the method used produced reliable results. The analysis confirmed the existence of mercury in this farming area.

  10. [Study of relationship between consumption of potassium permanganate and total organic carbon on plastic kitchen utensils, food packages and toys].

    Science.gov (United States)

    Ohno, Hiroyuki; Suzuki, Masako; Mutsuga, Motoh; Kawamura, Yoko

    2009-10-01

    Consumption of potassium permanganate and total organic carbon (TOC) were investigated as indices of total organic matter migrated into water from plastic kitchen utensils, food packages and toys for children. The samples were soaked in water at 60 or 95 degrees C for 30 min for kitchen utensils and food packages, and at 40 degrees C for 30 min for toys and the eluates were examined, using the two indices. The quantitation limits were both 0.5 microg/mL. Among 97 kitchen utensils and food packages tested, consumption of potassium permanganate and TOC were 0.5-10.9 microg/mL and ND-18.9 microg/mL for polyvinyl chloride (PVC) tea-pot spouts and nylon kitchen utensils, respectively. Among 32 toys tested, the levels were 0.8-45.5 microg/mL and 0.5-8.9 microg/mL from PVC toys and block toys made by ethylene vinyl acetate resin. The levels for other samples were very low. There were large discrepancies between consumption of potassium permanganate and TOC for some PVC products and nylon kitchen utensils. The cause may be a marked difference of the oxidation decomposition rate by potassium permanganate, depending on the kind of organic matter that migrated from the plastics.

  11. A Systematic Review of Measurement Properties of Patient-Reported Outcome Measures Used in Patients Undergoing Total Knee Arthroplasty.

    Science.gov (United States)

    Gagnier, Joel J; Mullins, Megan; Huang, Hsiaomin; Marinac-Dabic, Danica; Ghambaryan, Anna; Eloff, Benjamin; Mirza, Faisal; Bayona, Manuel

    2017-05-01

    While clinical research on total knee arthroplasty (TKA) outcomes is prevalent in the literature, studies often have poor methodological and reporting quality. A high-quality patient-reported outcome instrument is reliable, valid, and responsive. Many studies evaluate these properties, but none have done so with a systematic and accepted method. The objectives of this study were to identify patient-reported outcome measures (PROMs) for TKA, and to critically appraise, compare, and summarize their psychometric properties using accepted methods. MEDLINE, EMBASE, SCOPUS, Web of Science, PsycINFO, and SPORTDiscus were systematically searched for articles with the following inclusion criteria: publication before December 2014, English language, non-generic PRO, and evaluation in the TKA population. Methodological quality and evidence of psychometric properties were assessed with the COnsensus-based standards for the selection of health Status Measurement INstruments (COSMIN) checklist and criteria for psychometric evidence proposed by the COSMIN group and Terwee et al. One-hundred fifteen studies on 32 PROMs were included in this review. Only the Work, Osteoarthritis or joint-Replacement Questionnaire, the Oxford Knee Score, and the Western Ontario and McMaster Universities Arthritis Index had 4 or more properties with positive evidence. Most TKA PROMs have limited evidence for their psychometric properties. Although not all the properties were studied, the Work, Osteoarthritis or joint-Replacement Questionnaire, with the highest overall ratings, could be a useful PROM for evaluating patients undergoing TKA. The methods and reporting of this literature can improve by following accepted guidelines. Published by Elsevier Inc.

  12. The CP molecule labyrinth: a paradigm of how endeavors in total synthesis lead to discoveries and inventions in organic synthesis.

    Science.gov (United States)

    Nicolaou, K C; Baran, Phil S

    2002-08-02

    Imagine an artist carving a sculpture from a marble slab and finding gold nuggets in the process. This thought is not a far-fetched description of the work of a synthetic chemist pursuing the total synthesis of a natural product. At the end of the day, he or she will be judged by the artistry of the final work and the weight of the gold discovered in the process. However, as colorful as this description of total synthesis may be, it does not entirely capture the essence of the endeavor, for there is much more to be told, especially with regard to the contrast of frustrating failures and exhilarating moments of discovery. To fully appreciate the often Herculean nature of the task and the rewards that accompany it, one must sense the details of the enterprise behind the scenes. A more vivid description of total synthesis as a struggle against a tough opponent is perhaps appropriate to dramatize these elements of the experience. In this article we describe one such endeavor of total synthesis which, in addition to reaching the target molecule, resulted in a wealth of new synthetic strategies and technologies for chemical synthesis. The total synthesis of the CP molecules is compared to Theseus' most celebrated athlos (Greek for exploit, accomplishment): the conquest of the dreaded Minotaur, which he accomplished through brilliance, skill, and bravery having traversed the famous labyrinth with the help of Ariadne. This story from Greek mythology comes alive in modern synthetic expeditions toward natural products as exemplified by the total synthesis of the CP molecules which serve as a paradigm for modern total synthesis endeavors, where the objectives are discovery and invention in the broader sense of organic synthesis.

  13. Total protein

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/article/003483.htm Total protein To use the sharing features on this page, please enable JavaScript. The total protein test measures the total amount of two classes ...

  14. Friction in total hip joint prosthesis measured in vivo during walking.

    Science.gov (United States)

    Damm, Philipp; Dymke, Joern; Ackermann, Robert; Bender, Alwina; Graichen, Friedmar; Halder, Andreas; Beier, Alexander; Bergmann, Georg

    2013-01-01

    Friction-induced moments and subsequent cup loosening can be the reason for total hip joint replacement failure. The aim of this study was to measure the in vivo contact forces and friction moments during walking. Instrumented hip implants with Al2O3 ceramic head and an XPE inlay were used. In vivo measurements were taken 3 months post operatively in 8 subjects. The coefficient of friction was calculated in 3D throughout the whole gait cycle, and average values of the friction-induced power dissipation in the joint were determined. On average, peak contact forces of 248% of the bodyweight and peak friction moments of 0.26% bodyweight times meter were determined. However, contact forces and friction moments varied greatly between individuals. The friction moment increased during the extension phase of the joint. The average coefficient of friction also increased during this period, from 0.04 (0.03 to 0.06) at contralateral toe off to 0.06 (0.04 to 0.08) at contralateral heel strike. During the flexion phase, the coefficient of friction increased further to 0.14 (0.09 to 0.23) at toe off. The average friction-induced power throughout the whole gait cycle was 2.3 W (1.4 W to 3.8 W). Although more parameters than only the synovia determine the friction, the wide ranges of friction coefficients and power dissipation indicate that the lubricating properties of synovia are individually very different. However, such differences may also exist in natural joints and may influence the progression of arthrosis. Furthermore, subjects with very high power dissipation may be at risk of thermally induced implant loosening. The large increase of the friction coefficient during each step could be caused by the synovia being squeezed out under load.

  15. Detection of Total Knee Arthroplasties at Airport Security Checkpoints: How Do Updated Security Measures Affect Patients?

    Science.gov (United States)

    Issa, Kimona; Pierce, Todd P; Gwam, Chukwuweieke; Goljan, Peter; Festa, Anthony; Scillia, Anthony J; Mont, Michael A

    2017-07-01

    Airport security measures continue to be updated with the incorporation of the new body scanners and automatic target recognition software. The purpose of this study was analyze the incidence of: (1) triggering the security alarm; (2) extra security searches; (3) perceived inconvenience; and (4) presence of other surgical hardware in those who underwent total knee arthroplasty (TKA) and passed through airport security. A questionnaire was given to 125 consecutive patients with a TKA. Those who passed through airport security after January 2014 were considered for inclusion. A questionnaire was administered that addressed the number of encounters with airport security, metal detector activation, additional screening procedures, and perceived inconvenience. Out of the 125 patients, 53 met inclusion criteria. Out of the 53 patients, 20 (38%) reported that their prosthesis triggered a metal detector. Out of the 20 patients, 8 (40%) who reported triggering of metal detectors also reported the presence of surgical hardware elsewhere in the body. Eighteen of the 53 patients (34%) believed having a TKA was inconvenient for airplane travel. Compared with the historical cohort, alarms were triggered in 70 of 97 patients ( p  = 0.0001) and 50 of 97 reported inconvenience when traveling ( n  = 50 of 97 patients; p  = 0.04). The incidences of those who underwent TKA triggering alarms and perceiving inconvenience when passing through airport security have decreased from previously published studies. This is most likely due to the recent updates and modifications to screening. As these security measures are modified and implant designs continue to evolve, this is an area of investigation that should continue. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  16. Friction in total hip joint prosthesis measured in vivo during walking.

    Directory of Open Access Journals (Sweden)

    Philipp Damm

    Full Text Available Friction-induced moments and subsequent cup loosening can be the reason for total hip joint replacement failure. The aim of this study was to measure the in vivo contact forces and friction moments during walking. Instrumented hip implants with Al2O3 ceramic head and an XPE inlay were used. In vivo measurements were taken 3 months post operatively in 8 subjects. The coefficient of friction was calculated in 3D throughout the whole gait cycle, and average values of the friction-induced power dissipation in the joint were determined. On average, peak contact forces of 248% of the bodyweight and peak friction moments of 0.26% bodyweight times meter were determined. However, contact forces and friction moments varied greatly between individuals. The friction moment increased during the extension phase of the joint. The average coefficient of friction also increased during this period, from 0.04 (0.03 to 0.06 at contralateral toe off to 0.06 (0.04 to 0.08 at contralateral heel strike. During the flexion phase, the coefficient of friction increased further to 0.14 (0.09 to 0.23 at toe off. The average friction-induced power throughout the whole gait cycle was 2.3 W (1.4 W to 3.8 W. Although more parameters than only the synovia determine the friction, the wide ranges of friction coefficients and power dissipation indicate that the lubricating properties of synovia are individually very different. However, such differences may also exist in natural joints and may influence the progression of arthrosis. Furthermore, subjects with very high power dissipation may be at risk of thermally induced implant loosening. The large increase of the friction coefficient during each step could be caused by the synovia being squeezed out under load.

  17. Measurements and analysis of the 127I and 129I neutron capture and total cross sections

    International Nuclear Information System (INIS)

    Noguere, G.

    2005-01-01

    Most of the experimental work on the interaction of neutrons with matter has focused on materials important to reactor physics and reactor structures. By comparison, the corresponding data for minor actinides or long-lived fission products are poor. A significant demand has developed for improved neutron cross-section data of these little-studied nuclides due to the surge of interest in the transmutation of nuclear waste. With 400 kg of 129 I produced yearly in the reactors of the EU countries and a very long β - half-life of 1.57 x 10 7 years, iodine requires disposal strategies that will isolate this isotope from the environment for long periods of time. Therefore, 129 I is potentially a key long-lived fission product for transmutation applications, since 129 I transmutes in 130 I after a single neutron capture and decays to 130 Xe with a 12.36 h half-life. Accurate capture cross sections would help to reduce uncertainties in waste management concepts. For that purpose, Time-Of-Flight measurements covering the [0.5 eV-100 keV] energy range have been carried out at the 150 MeV pulsed neutron source GELINA of the Institute for Reference Materials and Measurements (IRMM). Two types of experiments have been performed at the IRMM, namely capture and transmission experiments. They are respectively related to the neutron capture and total cross sections. Since the PbI 2 samples used in this work contain natural and radioactive iodine, extensive measurements of 129 I have been carried out under the same experimental conditions as for the 129 I. The data reduction process was performed with the AGS system, and the resonance parameters were extracted with the SAMMY and REFIT shape analysis codes. In a last step, the parameters have been converted into ENDF-6 format and processed with the NJOY code to produce point-wise and multigroup cross sections, as well as MCNP and ERANOS libraries. (author)

  18. Investigation of the Makeup, Source, and Removal Strategies for Total Organic Carbon in the Oxygen Generation System Recirculation Loop

    Science.gov (United States)

    Bowman, Elizabeth M.; Carpenter, Joyce; Roy, Robert J.; Van Keuren, Steve; Wilson, Mark E.

    2015-01-01

    Since 2007, the Oxygen Generation System (OGS) on board the International Space Station (ISS) has been producing oxygen for crew respiration via water electrolysis. As water is consumed in the OGS recirculating water loop, make-up water is furnished by the ISS potable water bus. A rise in Total Organic Carbon (TOC) was observed beginning in February, 2011, which continues through the present date. Increasing TOC is of concern because the organic constituents responsible for the TOC were unknown and had not been identified; hence their impacts on the operation of the electrolytic cell stack components and on microorganism growth rates and types are unknown. Identification of the compounds responsible for the TOC increase, their sources, and estimates of their loadings in the OGA as well as possible mitigation strategies are presented.

  19. An unbiased stereological method for efficiently quantifying the innervation of the heart and other organs based on total length estimations

    DEFF Research Database (Denmark)

    Mühlfeld, Christian; Papadakis, Tamara; Krasteva, Gabriela

    2010-01-01

    Quantitative information about the innervation is essential to analyze the structure-function relationships of organs. So far, there has been no unbiased stereological tool for this purpose. This study presents a new unbiased and efficient method to quantify the total length of axons in a given...... reference volume, illustrated on the left ventricle of the mouse heart. The method is based on the following steps: 1) estimation of the reference volume; 2) randomization of location and orientation using appropriate sampling techniques; 3) counting of nerve fiber profiles hit by a defined test area within...

  20. Surface Sediment Analysis on Petroleum Hydrocarbon and Total Organic Carbon from Coastal Area of Papar to Tuaran, Sabah

    International Nuclear Information System (INIS)

    Siti Aishah Mohd Ali; Payus, C.; Masni Mohd Ali

    2015-01-01

    Total petroleum hydrocarbons (TPH) and total organic carbon (TOC) were investigated in surface sediments along coastal area of Papar to Tuaran, Sabah. Surface sediment samples were collected in 24 different stations in each area by using Ponar grab sampler. Samples were extracted for TPH using standard method sediment/ sludge APHA 5520E and analyzed using UV/VIS spectrophotometer while for TOC method analysis using United Nations Environment Programme (UNEP)/ MAP Athens (2006). The range of TPH concentrations in surface sediments were recorded at 0.24 - 20.65 mg/ kg dw Miri crude oil equivalents, meanwhile the TOC percentage ranged from 0.03 - 4.02 %. In the mean time, the statistical analysis by Pearson correlation showed a positive correlation with coefficient, r = 0.790 which showing the TPH concentrations significantly have influence on the TOC accumulations in the surface sediment. (author)

  1. TECHNICAL JUSTIFICATION FOR CHOOSING PROPANE AS A CALIBRATION AGENT FOR TOTAL FLAMMABLE VOLATILE ORGANIC COMPOUND (VOC) DETERMINATIONS

    International Nuclear Information System (INIS)

    DOUGLAS, J.G.

    2006-01-01

    This document presents the technical justification for choosing and using propane as a calibration standard for estimating total flammable volatile organic compounds (VOCs) in an air matrix. A propane-in-nitrogen standard was selected based on a number of criteria: (1) has an analytical response similar to the VOCs of interest, (2) can be made with known accuracy and traceability, (3) is available with good purity, (4) has a matrix similar to the sample matrix, (5) is stable during storage and use, (6) is relatively non-hazardous, and (7) is a recognized standard for similar analytical applications. The Waste Retrieval Project (WRP) desires a fast, reliable, and inexpensive method for screening the flammable VOC content in the vapor-phase headspace of waste containers. Table 1 lists the flammable VOCs of interest to the WRP. The current method used to determine the VOC content of a container is to sample the container's headspace and submit the sample for gas chromatography--mass spectrometry (GC-MS) analysis. The driver for the VOC measurement requirement is safety: potentially flammable atmospheres in the waste containers must be allowed to diffuse prior to processing the container. The proposed flammable VOC screening method is to inject an aliquot of the headspace sample into an argon-doped pulsed-discharge helium ionization detector (Ar-PDHID) contained within a gas chromatograph. No actual chromatography is performed; the sample is transferred directly from a sample loop to the detector through a short, inert transfer line. The peak area resulting from the injected sample is proportional to the flammable VOC content of the sample. However, because the Ar-PDHID has different response factors for different flammable VOCs, a fundamental assumption must be made that the agent used to calibrate the detector is representative of the flammable VOCs of interest that may be in the headspace samples. At worst, we desire that calibration with the selected calibrating

  2. Spatial Variation of Soil Organic Carbon and Total Nitrogen in the Coastal Area of Mid-Eastern China.

    Science.gov (United States)

    Xu, Yan; Pu, Lijie; Liao, Qilin; Zhu, Ming; Yu, Xue; Mao, Tianying; Xu, Chenxing

    2017-07-14

    Soils play an important role in sequestrating atmospheric CO₂. Coastal tidal flats have been intensively reclaimed for food security and living spaces worldwide. We aimed to identify the changes of soil organic carbon (SOC) and total nitrogen (TN) following coastal reclamation and their spatial variation in the coastal area of mid-Eastern China to provide information for coastal cropland management. We measured SOC and TN of 463 soil samples in the coastal plain of mid-Eastern China. The results showed that SOC and TN increased highly from the uncultivated coastal tidal flat (2.49 g·kg -1 and 0.21 g·kg -1 , respectively) to the cropland (10.73 g·kg -1 and 1.3 g·kg -1 , respectively). After long-term cultivation, SOC and TN in the old farmland (12.98 g·kg -1 and 1.49 g·kg -1 , respectively) were greater than those in the young farmland (5.76 g·kg -1 and 0.86 g·kg -1 , respectively). The density of SOC in the uncultivated coastal tidal flat, young farmland, and old farmland were 0.68 kg·C·m -2 , 1.52 kg·C·m -2 , and 3.31 kg·C·m -2 , respectively. The density of TN in the uncultivated coastal tidal flat, young farmland and old farmland were 0.05 kg·N·m -2 , 0.23 kg·N·m -2 , and 0.38 kg·N·m -2 , respectively. The C/N (11.17) in the uncultivated coastal tidal flat was highest comparing to that in the young and old farmland due to lower nitrogen. The C/N increased from 6.78 to 8.71 following cultivation. Reclaimed coastal tidal flats had high carbon and nitrogen sequestration potential that not only mitigated the threat of global warming, but also improved soil fertility for crop production. Coastal management of cropland should consider the spatial distribution of SOC and TN to improve ecosystem services of coastal soils.

  3. Diffusivity measurements of volatile organics in levitated viscous aerosol particles

    Science.gov (United States)

    Bastelberger, Sandra; Krieger, Ulrich K.; Luo, Beiping; Peter, Thomas

    2017-07-01

    Field measurements indicating that atmospheric secondary organic aerosol (SOA) particles can be present in a highly viscous, glassy state have spurred numerous studies addressing low diffusivities of water in glassy aerosols. The focus of these studies is on kinetic limitations of hygroscopic growth and the plasticizing effect of water. In contrast, much less is known about diffusion limitations of organic molecules and oxidants in viscous matrices. These may affect atmospheric chemistry and gas-particle partitioning of complex mixtures with constituents of different volatility. In this study, we quantify the diffusivity of a volatile organic in a viscous matrix. Evaporation of single particles generated from an aqueous solution of sucrose and small amounts of volatile tetraethylene glycol (PEG-4) is investigated in an electrodynamic balance at controlled relative humidity (RH) and temperature. The evaporative loss of PEG-4 as determined by Mie resonance spectroscopy is used in conjunction with a radially resolved diffusion model to retrieve translational diffusion coefficients of PEG-4. Comparison of the experimentally derived diffusivities with viscosity estimates for the ternary system reveals a breakdown of the Stokes-Einstein relationship, which has often been invoked to infer diffusivity from viscosity. The evaporation of PEG-4 shows pronounced RH and temperature dependencies and is severely depressed for RH ≲ 30 %, corresponding to diffusivities pollutant molecules such as polycyclic aromatic hydrocarbons (PAHs).

  4. Measurement of organically bound tritium in urine and feces

    International Nuclear Information System (INIS)

    Trivedi, A.; Duong, T.; Leon, J.W.; Linauskas, S.H.

    1993-11-01

    A bioassay method was developed for directly measuring organically bound tritium (OBT) in urine and feces. Samples first undergo low-temperature distillation and vacuum separation to isolate tritiated water (HTO) and exchangeable tritium. This is followed by converting the non-exchangeable tritium (i.e., OBT) into HTO through oxygen combustion. The method was investigated to: optimise the sample preparation procedures; establish OBT recovery (64% ± 7% for urine and 71% ± 8% for feces); and, determine the detection limit for OBT in urine (0.3 Bq · g -1 ) and feces (5 Bq · g -1 ). The method was evaluated for error sources that are associated with the exchange between HTO and OBT. It is concluded that this bioassay method can reliably measure OBT in urine and feces within the range of ± 10%

  5. Total-ozone and nitrogen-dioxide measurements at the Molodezhnaya and Mirnyi Antarctic stations during spring 1987-autumn 1988

    Energy Technology Data Exchange (ETDEWEB)

    Elokhov, A.S.; Gruzdev, A.N. (AN SSSR, Institut Fiziki Atmosfery, Moscow, (USSR))

    1991-09-01

    Results of measurements of the total-ozone and NO2 content during November-December (Molodezhnaya) and February-April 1988 (Mirnyi) are reported. During the November-December period an irregular total ozone increase was observed, which characterized the filling up of the ozone hole. Stratospheric warming and the total NO2 increase occurred simultaneously. During the summer-autumn period the total NO2 content decreased gradually. The evening total NO2 content was systematically greater than the morning one, which reflects changes in the NO2 abundance from day to night. 12 refs.

  6. Soil Organic Carbon Fractions and Stocks Respond to Restoration Measures in Degraded Lands by Water Erosion.

    Science.gov (United States)

    Nie, Xiaodong; Li, Zhongwu; Huang, Jinquan; Huang, Bin; Xiao, Haibing; Zeng, Guangming

    2017-05-01

    Assessing the degree to which degraded soils can be recovered is essential for evaluating the effects of adopted restoration measures. The objective of this study was to determine the restoration of soil organic carbon under the impact of terracing and reforestation. A small watershed with four typical restored plots (terracing and reforestation (four different local plants)) and two reference plots (slope land with natural forest (carbon-depleted) and abandoned depositional land (carbon-enriched)) in subtropical China was studied. The results showed that soil organic carbon, dissolved organic carbon and microbial biomass carbon concentrations in the surface soil (10 cm) of restored lands were close to that in abandoned depositional land and higher than that in natural forest land. There was no significant difference in soil organic carbon content among different topographic positions of the restored lands. Furthermore, the soil organic carbon stocks in the upper 60 cm soils of restored lands, which were varied between 50.08 and 62.21 Mg C ha -1 , were higher than 45.90 Mg C ha -1 in natural forest land. Our results indicated that the terracing and reforestation could greatly increase carbon sequestration and accumulation and decrease carbon loss induced by water erosion. And the combination measures can accelerate the restoration of degraded soils when compared to natural forest only. Forest species almost have no impact on the total amount of soil organic carbon during restoration processes, but can significantly influence the activity and stability of soil organic carbon. Combination measures which can provide suitable topography and continuous soil organic carbon supply could be considered in treating degraded soils caused by water erosion.

  7. Soil Organic Carbon Fractions and Stocks Respond to Restoration Measures in Degraded Lands by Water Erosion

    Science.gov (United States)

    Nie, Xiaodong; Li, Zhongwu; Huang, Jinquan; Huang, Bin; Xiao, Haibing; Zeng, Guangming

    2017-05-01

    Assessing the degree to which degraded soils can be recovered is essential for evaluating the effects of adopted restoration measures. The objective of this study was to determine the restoration of soil organic carbon under the impact of terracing and reforestation. A small watershed with four typical restored plots (terracing and reforestation (four different local plants)) and two reference plots (slope land with natural forest (carbon-depleted) and abandoned depositional land (carbon-enriched)) in subtropical China was studied. The results showed that soil organic carbon, dissolved organic carbon and microbial biomass carbon concentrations in the surface soil (10 cm) of restored lands were close to that in abandoned depositional land and higher than that in natural forest land. There was no significant difference in soil organic carbon content among different topographic positions of the restored lands. Furthermore, the soil organic carbon stocks in the upper 60 cm soils of restored lands, which were varied between 50.08 and 62.21 Mg C ha-1, were higher than 45.90 Mg C ha-1 in natural forest land. Our results indicated that the terracing and reforestation could greatly increase carbon sequestration and accumulation and decrease carbon loss induced by water erosion. And the combination measures can accelerate the restoration of degraded soils when compared to natural forest only. Forest species almost have no impact on the total amount of soil organic carbon during restoration processes, but can significantly influence the activity and stability of soil organic carbon. Combination measures which can provide suitable topography and continuous soil organic carbon supply could be considered in treating degraded soils caused by water erosion.

  8. Micrometeorological measurements of ammonia and total reactive nitrogen exchange over semi-natural peatland

    Science.gov (United States)

    Brümmer, Christian; Richter, Undine; Schrader, Frederik; Kutsch, Werner

    2015-04-01

    Intensive agriculture generates a substantial atmospheric burden for nitrogen-limited ecosystems such as peatlands when the latter are located in close vicinity to arable sites and animal houses. The exchange of reactive nitrogen compounds between these bog ecosystems and the atmosphere is still not very well understood due to the lack of suitable measurement techniques. With recent advancements in laser spectrometry, we used a quantum cascade laser spectrometer as well as a custom-built total reactive atmospheric nitrogen (ΣNr) converter (TRANC) coupled to a fast-response chemiluminescence detector to measure NH3 and ΣNr concentrations, respectively. The analyzers' high temporal resolution allowed for determination of the respective nitrogen exchange within eddy covariance-based setups. Field campaigns were conducted at a northwestern German peatland site that is surrounded by an area of highly fertilized agricultural land and intensive livestock production (~1 km distance). The field site is part of a natural park with a very small remaining protected zone of less than 2 km x 2 km. Ammonia and ΣNr concentrations were highly variable between 2 to 110 ppb and 10 to 120 ppb, respectively. Peak values coincided with main fertilization periods on the neighboring agricultural land in early spring and fall. The trend in weekly averaged ΣNr concentrations from TRANC measurements was in good agreement with results from KAPS denuder filter systems when the latter were combined with the missing and apparently highly variable NOx contribution. Wind direction and land use in the closer vicinity clearly regulated whether ΣNr concentrations were NH3 or NOx-dominated. Ammonia uptake rates between 40 ng N m-2 s-1 and near-neutral exchange were observed. The cumulative net uptake for the period of investigation was ~700 g N ha-1 resulting in a dry net deposition of ~4 kg N ha-1 when extrapolated to an entire year, whereas KAPS denuder measurements in combination with dry

  9. A simple approach to estimate daily loads of total, refractory, and labile organic carbon from their seasonal loads in a watershed.

    Science.gov (United States)

    Ouyang, Ying; Grace, Johnny M; Zipperer, Wayne C; Hatten, Jeff; Dewey, Janet

    2018-05-22

    Loads of naturally occurring total organic carbons (TOC), refractory organic carbon (ROC), and labile organic carbon (LOC) in streams control the availability of nutrients and the solubility and toxicity of contaminants and affect biological activities through absorption of light and complex metals with production of carcinogenic compounds. Although computer models have become increasingly popular in understanding and management of TOC, ROC, and LOC loads in streams, the usefulness of these models hinges on the availability of daily data for model calibration and validation. Unfortunately, these daily data are usually insufficient and/or unavailable for most watersheds due to a variety of reasons, such as budget and time constraints. A simple approach was developed here to calculate daily loads of TOC, ROC, and LOC in streams based on their seasonal loads. We concluded that the predictions from our approach adequately match field measurements based on statistical comparisons between model calculations and field measurements. Our approach demonstrates that an increase in stream discharge results in increased stream TOC, ROC, and LOC concentrations and loads, although high peak discharge did not necessarily result in high peaks of TOC, ROC, and LOC concentrations and loads. The approach developed herein is a useful tool to convert seasonal loads of TOC, ROC, and LOC into daily loads in the absence of measured daily load data.

  10. Using 137Cs to quantify the redistribution of soil organic carbon and total N affected by intensive soil erosion in the headwaters of the Yangtze River, China

    International Nuclear Information System (INIS)

    Wei Guoxiao; Wang Yibo; Wang Yanlin

    2008-01-01

    Characteristics of soil organic carbon (SOC) and total nitrogen (total N) are important for determining the overall quality of soils. Studies on spatial and temporal variation in SOC and total N are of great importance because of global environmental concerns. Soil erosion is one of the major processes affecting the redistribution of SOC and total N in the test fields. To characterize the distribution and dynamics of SOC and N in the intensively eroded soil of the headwaters of the Yangtze River, China, we measured profiles of soil organic C, total N stocks, and 137 Cs in a control plot and a treatment plot. The amounts of SOC, 137 Cs of sampling soil profiles increased in the following order, lower>middle>upper portions on the control plot, and the amounts of total N of sampling soil profile increase in the following order: upper>middle>lower on the control plot. Intensive soil erosion resulted in a significant decrease of SOC amounts by 34.9%, 28.3% and 52.6% for 0-30 cm soil layer at upper, middle and lower portions and 137 Cs inventory decreased by 68%, 11% and 85% at upper, middle and lower portions, respectively. On the treatment plot total N decreased by 50.2% and 14.6% at the upper and middle portions and increased by 48.9% at the lower portion. Coefficients of variation (CVs) of SOC decreased by 31%, 37% and 30% in the upper, middle and lower slope portions, respectively. Similar to the variational trend of SOC, CVs of 137 Cs decreased by 19.2%, 0.5% and 36.5%; and total N decreased by 45.7%, 65.1% and 19% in the upper, middle and lower slope portions, respectively. The results showed that 137 Cs, SOC and total N moved on the sloping land almost in the same physical mechanism during the soil erosion procedure, indicating that fallout of 137 Cs could be used directly for quantifying dynamic SOC and total N redistribution as the soil was affected by intensive soil erosion

  11. Using (137)Cs to quantify the redistribution of soil organic carbon and total N affected by intensive soil erosion in the headwaters of the Yangtze River, China.

    Science.gov (United States)

    Guoxiao, Wei; Yibo, Wang; Yan Lin, Wang

    2008-12-01

    Characteristics of soil organic carbon (SOC) and total nitrogen (total N) are important for determining the overall quality of soils. Studies on spatial and temporal variation in SOC and total N are of great importance because of global environmental concerns. Soil erosion is one of the major processes affecting the redistribution of SOC and total N in the test fields. To characterize the distribution and dynamics of SOC and N in the intensively eroded soil of the headwaters of the Yangtze River, China, we measured profiles of soil organic C, total N stocks, and (137)Cs in a control plot and a treatment plot. The amounts of SOC, (137)Cs of sampling soil profiles increased in the following order, lower>middle>upper portions on the control plot, and the amounts of total N of sampling soil profile increase in the following order: upper>middle>lower on the control plot. Intensive soil erosion resulted in a significant decrease of SOC amounts by 34.9%, 28.3% and 52.6% for 0-30cm soil layer at upper, middle and lower portions and (137)Cs inventory decreased by 68%, 11% and 85% at upper, middle and lower portions, respectively. On the treatment plot total N decreased by 50.2% and 14.6% at the upper and middle portions and increased by 48.9% at the lower portion. Coefficients of variation (CVs) of SOC decreased by 31%, 37% and 30% in the upper, middle and lower slope portions, respectively. Similar to the variational trend of SOC, CVs of (137)Cs decreased by 19.2%, 0.5% and 36.5%; and total N decreased by 45.7%, 65.1% and 19% in the upper, middle and lower slope portions, respectively. The results showed that (137)Cs, SOC and total N moved on the sloping land almost in the same physical mechanism during the soil erosion procedure, indicating that fallout of (137)Cs could be used directly for quantifying dynamic SOC and total N redistribution as the soil was affected by intensive soil erosion.

  12. Measuring the pollutant transport capacity of dissolved organic matter in complex matrixes

    DEFF Research Database (Denmark)

    Persson, L.; Alsberg, T.; Odham, G.

    2003-01-01

    Dissolved organic matter (DOM) facilitated transport in contaminated groundwater was investigated through the measurement of the binding capacity of landfill leachate DOM (Vejen, Denmark) towards two model pollutants (pyrene and phenanthrene). Three different methods for measuring binding capacity....... It was further concluded that DOM facilitated transport should be taken into account for non-ionic PAHs with lg K OW above 5, at DOM concentrations above 250 mg C/L. The total DOM concentration was found to be more important for the potential of facilitated transport than differences in the DOM binding capacity....

  13. Application of isotope dilution method for measuring bioavailability of organic contaminants sorbed to dissolved organic matter (DOM)

    Energy Technology Data Exchange (ETDEWEB)

    Delgado-Moreno, Laura, E-mail: laura.delgado@eez.csic.es; Wu, Laosheng; Gan, Jay

    2015-08-15

    Natural waters such as surface water and sediment porewater invariably contain dissolved organic matter (DOM). Association of strongly hydrophobic contaminants (HOCs) with DOM leads to decreased toxicity and bioavailability, but bioavailability of DOM-sorbed HOCs is difficult to measure. Current methods to estimate bioavailability of HOCs in water are based on only the freely dissolved concentration (C{sub free}). The ignorance of the exchangeable fraction of HOCs sorbed on DOM may result in an underestimation of the toxicity potential of HOCs to aquatic organisms. Here we explore the applicability of an isotope dilution method (IDM) to measuring the desorption fraction of DOM-sorbed pyrene and bifenthrin and determining their exchangeable pool (E) as an approximation of bioavailability. E values, expressed as percentage of the total concentration, ranged between 0.80 and 0.92% for pyrene and 0.74 and 0.85% for bifenthrin, depending primarily on the amount of chemical in the freely dissolved form. However, between 34 and 78% of the DOM-sorbed pyrene was exchangeable. This fraction ranged between 23% and 82% for bifenthrin. The ability of IDM to predict bioavailability was further shown from a significant relationship (r{sup 2} > 0.72, P < 0.0001) between E and bioaccumulation into Daphnia magna. Therefore, IDM may be used to improve the bioavailability measurement and risk assessment of HOCs in aquatic systems.

  14. Application of isotope dilution method for measuring bioavailability of organic contaminants sorbed to dissolved organic matter (DOM)

    International Nuclear Information System (INIS)

    Delgado-Moreno, Laura; Wu, Laosheng; Gan, Jay

    2015-01-01

    Natural waters such as surface water and sediment porewater invariably contain dissolved organic matter (DOM). Association of strongly hydrophobic contaminants (HOCs) with DOM leads to decreased toxicity and bioavailability, but bioavailability of DOM-sorbed HOCs is difficult to measure. Current methods to estimate bioavailability of HOCs in water are based on only the freely dissolved concentration (C free ). The ignorance of the exchangeable fraction of HOCs sorbed on DOM may result in an underestimation of the toxicity potential of HOCs to aquatic organisms. Here we explore the applicability of an isotope dilution method (IDM) to measuring the desorption fraction of DOM-sorbed pyrene and bifenthrin and determining their exchangeable pool (E) as an approximation of bioavailability. E values, expressed as percentage of the total concentration, ranged between 0.80 and 0.92% for pyrene and 0.74 and 0.85% for bifenthrin, depending primarily on the amount of chemical in the freely dissolved form. However, between 34 and 78% of the DOM-sorbed pyrene was exchangeable. This fraction ranged between 23% and 82% for bifenthrin. The ability of IDM to predict bioavailability was further shown from a significant relationship (r 2 > 0.72, P < 0.0001) between E and bioaccumulation into Daphnia magna. Therefore, IDM may be used to improve the bioavailability measurement and risk assessment of HOCs in aquatic systems

  15. Comparison of Transcutaneous Bilirubin Measurement With Total Serum Bilirubin Levels in Preterm Neonates Receiving Phototherapy.

    Science.gov (United States)

    Pendse, Amruta; Jasani, Bonny; Nanavati, Ruchi; Kabra, Nandkishor

    2017-08-15

    To compare transcutaneous bilirubin with total serum bilirubin in preterm neonates after initiation of phototherapy. Jaundice was assessed in 30 preterm neonates with transcutaneous bilirubin and total serum bilirubin before initiation of phototherapy and at 12 hr after initiation of phototherapy. A photo-occlusive patch was applied over the sternum. Transcutaneous bilirubin has a good correlation with total serum bilirubin after initiation of phototherapy. (r=0.918, Pbilirubin at 28-32 weeks of gestation (r = 0.97) was better correlated with total serum bilirubin than those at 32-37 weeks (r =0.88). The correlation was better for neonates 72 hours of age (r = 0.82). Transcutaneous bilirubin correlates significantly with total serum bilirubin at the patched sternal site after initiation of phototherapy in preterm neonates.

  16. Response surface modeling for optimization heterocatalytic Fenton oxidation of persistence organic pollution in high total dissolved solid containing wastewater.

    Science.gov (United States)

    Sekaran, G; Karthikeyan, S; Boopathy, R; Maharaja, P; Gupta, V K; Anandan, C

    2014-01-01

    The rice-husk-based mesoporous activated carbon (MAC) used in this study was precarbonized and activated using phosphoric acid. N2 adsorption/desorption isotherm, X-ray powder diffraction, electron spin resonance, X-ray photoelectron spectroscopy and scanning electron microscopy, transmission electron microscopy, (29)Si-NMR spectroscopy, and diffuse reflectance spectroscopy were used to characterize the MAC. The tannery wastewater carrying high total dissolved solids (TDS) discharged from leather industry lacks biodegradability despite the presence of dissolved protein. This paper demonstrates the application of free electron-rich MAC as heterogeneous catalyst along with Fenton reagent for the oxidation of persistence organic compounds in high TDS wastewater. The heterogeneous Fenton oxidation of the pretreated wastewater at optimum pH (3.5), H2O2 (4 mmol/L), FeSO4[Symbol: see text]7H2O (0.2 mmol/L), and time (4 h) removed chemical oxygen demand, biochemical oxygen demand, total organic carbon and dissolved protein by 86, 91, 83, and 90%, respectively.

  17. Simultaneous measurement of milk intake and total energy expenditure in mixed-fed infants: Methodological approach and prediction of total body water

    International Nuclear Information System (INIS)

    Wells, J.C.K.; Davies, P.S.W.; Coward, W.A.

    2000-01-01

    Evaluation of the energy metabolism that underlies the new WHO breast-fed growth reference requires simultaneous measurements of milk volume intake (MVI) and total energy expenditure (TEE) by stable isotope methodologies. In young infants, such data is collected without difficulty using the dose-to-the-infant method. In older infants, where breast-milk is supplemented with non-milk foods, MVI must be measured by dosing the mother instead of the infant. This procedure would interfere with a simple measurement of infant TEE using the standard dose-to-the-infant method. Theoretically, this difficulty can be resolved by dosing the mother with deuterium and the infant with 18-oxygen, and using curve-peeling methods to calculate the infant deuterium kinetics. We propose to ascertain whether such an approach is viable in practice, such that MVI, TEE and body composition could all be measured simultaneously in mixed-fed infants. Where MVI in older infants is measured on its own, there is a need to predict infant body water in order to estimate the deuterium dilution space. Using a database of 234 infants aged 1.5 to 12 months, we provide new predictive equations by which such values may be obtained. (author)

  18. Validating an instrument for measuring brand equity of CSR driven organizations in Malaysia

    Directory of Open Access Journals (Sweden)

    Singh Dara Singh Karpal

    2017-06-01

    Full Text Available The objective of this study is to develop and propose a valid and reliable instrument to measure brand equity of CSR driven organizations in Malaysia. An instrument to measure brand equity was constructed with adaptations from two key sources, namely Yew Leh and Lee (2011 and Yoo and Donthu (2001. As such the study only focuses on the development and validation of an instrument to measure brand equity of CSR driven organizations. The usable sample population included 909 respondents from 12 states of West Malaysia which were selected using a quota sampling plan. Confirmatory factor analysis (CFA and reliability analysis were carried out to test and validate the proposed brand equity instrument containing four components (brand awareness, brand association, perceived quality and brand loyalty with a total of 13 items. Results from the CFA and reliability analysis indicated that all the items representing the four components were valid and can be used to measure the brand equity of organizations that are practicing CSR. The study tried to set an empirical basis for brand equity and CSR related research which could be used by future researchers in different industries and geographical locations. The study also implies the need for organizations to assess the success of their CSR efforts through the use of the proposed instrument in order to gauge whether all their CSR efforts translate to improved brand equity.

  19. Measurement of stable isotope ratio of organic carbon in water samples

    International Nuclear Information System (INIS)

    Fujii, Toshihiro; Otsuki, Akira

    1977-01-01

    A new method for the measurement of stable isotope ratios was investigated and applied to organic carbon's isotope ratio measurements in water samples. A few river water samples from Tsuchiura city were tested. After the wet oxidation of organic carbons to carbon dioxide in a sealed ampoule, the isotope ratios were determined with the gas chromatograph-quadrupole mass spectrometer combined with a total organic carbon analyser, under the dynamic conditions. The GC-MS had been equipped with the multiple ion detector-digital integrator system. The ion intensities at m/e 44 and 45 were simultaneously measured at a switching rate of 1 ms. The measurements with carbon dioxide acquired from sodium carbonate (53 μg) gave the isotope ratios with the variation coefficient of 0.62%. However, the variation coefficients obtained from organic carbons in natural water samples were 2 to 3 times as high as that from sodium carbonate. This method is simple and rapid and may be applied to various fields especially in biology and medicine. (auth.)

  20. Total organic carbon in a soil recovered with sewage sludge and native species of the Atlantic Forest

    Science.gov (United States)

    Mara Lima Goulart, Lívia; Amaral Guerrini, Iraê; Fidalgo de Faria, Marianne; Spada, Grasiela; Proença Nalesso, Pedro Henrique; Willian Carlos, Guilherme

    2017-04-01

    The use of organic waste such as sewage sludge, in the recovery of degraded áreas have shown very satisfactory results, because they are constituted by high contentes of organic matter and nutrients, essential to improve the physical and chemical properties of the soil. Thus, the objective of this study was to verify the total organic carbon (TOC) of a degraded soil, up to a metre deep, after 10 years of application of sewage sludge and planting native species of the Atlantic forest. The experiment was conducted at Fazenda Entre-Rios, owned by Suzano Papel e Celulose, in Itatinga, São Paulo, Brazil. The experiment was designed as randomized block with four replications, six doses of sewage sludge (0, 2.5, 5, 10, 15 and 20 t ha-1), conventional chemical fertilizer and only with potassium application, totaling eight treatments. Samples were collected every 20 cm (0-20, 20-40, 40-60, 60-80 and 80-100 cm) until reaching a metre deep. Ten years after trial deployment, the sewage sludge application in degraded soil was significantly influenced the TOC at all depths sampled. The highest values of the COT were observed in plots that received 15 and 20 t ha-1 of sewage sludge, in all depths sampled, except for the layer of 80-100 cm, which presented the highest average COT in the treatment with 10 t ha-1 of residue. As observed for all treatments, the highest TOC averages were observed in the superficial layers of the soil (0-20 and 20-40 cm). The sewage sludge application is useful to recover degraded soils, as it improving their chemical characteristics and showing to be a good alternative to the final destination of this residue.

  1. Studies on fission with ALADIN. Precise and simultaneous measurement of fission yields, total kinetic energy and total prompt neutron multiplicity at GSI

    International Nuclear Information System (INIS)

    Martin, Julie-Fiona; Taieb, Julien; Chatillon, Audrey; Belier, Gilbert; Boutoux, Guillaume; Ebran, Adeline; Gorbinet, Thomas; Grente, Lucie; Laurent, Benoit; Pellereau, Eric; Alvarez-Pol, Hector; Ayyad, Yassid; Benlliure, Jose; Cortina Gil, Dolores; Caamano, Manuel; Fernandez Dominguez, Beatriz; Paradela, Carlos; Ramos, Diego; Rodriguez-Sanchez, Jose-Luis; Vargas, Jossitt; Audouin, Laurent; Tassan-Got, Laurent; Aumann, Thomas; Casarejos, Enrique; Farget, Fanny; Rodriguez-Tajes, Carme; Heinz, Andreas; Jurado, Beatriz; Kelic-Heil, Aleksandra; Kurz, Nikolaus; Nociforo, Chiara; Pietri, Stephane; Rossi, Dominic; Schmidt, Karl-Heinz; Simon, Haik; Voss, Bernd; Weick, Helmut

    2015-01-01

    A novel technique for fission studies, based on the inverse kinematics approach, is presented. Following pioneering work in the nineties, the SOFIA Collaboration has designed and built an experimental set-up dedicated to the simultaneous measurement of isotopic yields, total kinetic energies and total prompt neutron multiplicities, by fully identifying both fission fragments in coincidence, for the very first time. This experiment, performed at GSI, permits to study the fission of a wide variety of fissioning systems, ranging from mercury to neptunium, possibly far from the valley of stability. A first experiment, performed in 2012, has provided a large array of unprecedented data regarding the nuclear fission process. An excerpt of the results is presented. With this solid starter, further improvements of the experimental set-up are considered, which are consistent with the expected developments at the GSI facility, in order to measure more fission observables in coincidence. The completeness reached in the SOFIA data, permits to scrutinize the correlations between the interesting features of fission, offering a very detailed insight in this still unraveled mechanism. (orig.)

  2. Studies on fission with ALADIN. Precise and simultaneous measurement of fission yields, total kinetic energy and total prompt neutron multiplicity at GSI

    Energy Technology Data Exchange (ETDEWEB)

    Martin, Julie-Fiona; Taieb, Julien; Chatillon, Audrey; Belier, Gilbert; Boutoux, Guillaume; Ebran, Adeline; Gorbinet, Thomas; Grente, Lucie; Laurent, Benoit; Pellereau, Eric [CEA DAM Bruyeres-le-Chatel, Arpajon (France); Alvarez-Pol, Hector; Ayyad, Yassid; Benlliure, Jose; Cortina Gil, Dolores; Caamano, Manuel; Fernandez Dominguez, Beatriz; Paradela, Carlos; Ramos, Diego; Rodriguez-Sanchez, Jose-Luis; Vargas, Jossitt [Universidad de Santiago de Compostela, Santiago de Compostela (Spain); Audouin, Laurent; Tassan-Got, Laurent [CNRS/IN2P3, IPNO, Orsay (France); Aumann, Thomas [Technische Universitaet Darmstadt, Darmstadt (Germany); Casarejos, Enrique [Universidad de Vigo, Vigo (Spain); Farget, Fanny; Rodriguez-Tajes, Carme [CNRS/IN2P3, GANIL, Caen (France); Heinz, Andreas [Chalmers University of Technology, Gothenburg (Sweden); Jurado, Beatriz [CNRS/IN2P3, CENBG, Gradignan (France); Kelic-Heil, Aleksandra; Kurz, Nikolaus; Nociforo, Chiara; Pietri, Stephane; Rossi, Dominic; Schmidt, Karl-Heinz; Simon, Haik; Voss, Bernd; Weick, Helmut [GSI Helmholtzzentrum fuer Schwerionenforschung GmbH, Darmstadt (Germany)

    2015-12-15

    A novel technique for fission studies, based on the inverse kinematics approach, is presented. Following pioneering work in the nineties, the SOFIA Collaboration has designed and built an experimental set-up dedicated to the simultaneous measurement of isotopic yields, total kinetic energies and total prompt neutron multiplicities, by fully identifying both fission fragments in coincidence, for the very first time. This experiment, performed at GSI, permits to study the fission of a wide variety of fissioning systems, ranging from mercury to neptunium, possibly far from the valley of stability. A first experiment, performed in 2012, has provided a large array of unprecedented data regarding the nuclear fission process. An excerpt of the results is presented. With this solid starter, further improvements of the experimental set-up are considered, which are consistent with the expected developments at the GSI facility, in order to measure more fission observables in coincidence. The completeness reached in the SOFIA data, permits to scrutinize the correlations between the interesting features of fission, offering a very detailed insight in this still unraveled mechanism. (orig.)

  3. Measurement of the total solar energy transmittance (g-value) for complex glazings

    DEFF Research Database (Denmark)

    Duer, Karsten

    1999-01-01

    Four different complex glazings have been investigated in the Danish experimental setup METSET.The purpose of the measurements is to increase the confidence in the calorimetric measurements and to perform measurements and corrections according to a method developed in the ALTSET project...

  4. Total variation regularization in measurement and image space for PET reconstruction

    KAUST Repository

    Burger, M

    2014-09-18

    © 2014 IOP Publishing Ltd. The aim of this paper is to test and analyse a novel technique for image reconstruction in positron emission tomography, which is based on (total variation) regularization on both the image space and the projection space. We formulate our variational problem considering both total variation penalty terms on the image and on an idealized sinogram to be reconstructed from a given Poisson distributed noisy sinogram. We prove existence, uniqueness and stability results for the proposed model and provide some analytical insight into the structures favoured by joint regularization. For the numerical solution of the corresponding discretized problem we employ the split Bregman algorithm and extensively test the approach in comparison to standard total variation regularization on the image. The numerical results show that an additional penalty on the sinogram performs better on reconstructing images with thin structures.

  5. Using value-based total cost of ownership (TCO) measures to inform subsystem trade-offs

    Science.gov (United States)

    Radziwill, Nicole M.; DuPlain, Ronald F.

    2010-07-01

    Total Cost of Ownership (TCO) is a metric from management accounting that helps expose both the direct and indirect costs of a business decision. However, TCO can sometimes be too simplistic for "make vs. buy" decisions (or even choosing between competing design alternatives) when value and extensibility are more critical than total cost. A three-dimensional value-based TCO, which was developed to clarify product decisions for an observatory prior to Final Design Review (FDR), will be presented in this session. This value-based approach incorporates priority of requirements, satisfiability of requirements, and cost, and can be easily applied in any environment.

  6. Relationship of bifenthrin sediment concentrations to grain size and total organic carbon in California waterbodies: implications for ecological risk.

    Science.gov (United States)

    Hall, Lenwood W; Anderson, Ronald D

    2014-12-01

    A summary analysis of data sets from six California waterbodies was conducted to determine the relationship of bifenthrin sediment concentrations to: % sand/gravel; % silt; % clay; % silt/clay and % total organic carbon (TOC). The relationship of TOC to % sand/gravel, % silt, % clay, and % silt/clay was also analyzed. Statistically significant and meaningful direct relationships were reported between bifenthrin and % TOC, % silt, % clay and % silt/clay while a significant and meaningful inverse relationship was reported between bifenthrin and % sand/gravel. A significant and meaningful inverse relationship was reported between % TOC and % sand/gravel, while a significant and meaningful direct relationship was reported between % TOC and % silt, % clay and % silt/clay. Significant bifenthrin sediment concentrations would not be expected in non-depositional (sand/gravel) areas which have been reported to be dominant in various streams in California's Central Valley and are also the preferred habitat for many benthic macroinvertebrate taxa.

  7. Effect of temperature and pH on dehalogenation of total organic chlorine, bromine and iodine in drinking water.

    Science.gov (United States)

    Abusallout, Ibrahim; Rahman, Shamimur; Hua, Guanghui

    2017-11-01

    Disinfection byproduct (DBP) concentrations in drinking water distribution systems and indoor water uses depend on competitive formation and degradation reactions. This study investigated the dehalogenation kinetics of total organic chlorine (TOCl), bromine (TOBr) and iodine (TOI) produced by fulvic acid under different pH and temperature conditions, and total organic halogen (TOX) variations in a treated drinking water under simulated distribution system and heating scenarios. TOX dehalogenation rates were generally in the order of TOI ≅ TOCl(NH 2 Cl) > TOBr > TOCl(Cl 2 ). The half-lives of different groups of TOX compounds formed by fulvic acid varied between 27 and 139 days during incubation at 20 °C and 0.98-2.17 days during heating at 55 °C. Base-catalyzed reactions played a major role in TOX degradation as evidenced by enhanced dehalogenation under high pH conditions. The results of heating of a treated water in the presence of residuals showed that TOX concentrations of chlorinated samples increased rapidly when chlorine residuals were present and then gradually decreased after chlorine residuals were exhausted. The final TOX concentrations of chlorinated samples after heating showed moderate decreases with increasing ambient water ages. Chloraminated samples with different ambient water ages exhibited similar final TOX concentrations during simulated distribution system and heating experiments. This study reinforces the importance of understanding DBP variations in indoor water uses as wells as in distribution systems to provide more accurate DBP information for exposure assessment and regulatory determination. Published by Elsevier Ltd.

  8. VARIABILITY OF FORCED OSCILLATION (SIEMENS SIREGNOST FD-5) MEASUREMENTS OF TOTAL RESPIRATORY RESISTANCE IN PATIENTS AND HEALTHY-SUBJECTS

    NARCIS (Netherlands)

    GIMENO, F; VANDERWEELE, LT; KOETER, GH; DEMONCHY, JGR; VANALTENA, R

    The reproducibility of total respiratory resistance (R(rs)) measured with a simplified forced oscillatory method (Siemens Siregnost FD 5) was measured and compared with that of slow inspiratory vital capacity (IVC) and forced expiratory volume in one second (FEV1). The former technique has the

  9. Determination of total antioxidant capacity by a new spectrophotometric method based on Ce(IV) reducing capacity measurement.

    Science.gov (United States)

    Ozyurt, Dilek; Demirata, Birsen; Apak, Resat

    2007-02-28

    Dietary antioxidants widely found in fruits and vegetables may serve the task of reducing oxidative damage in humans induced by free radicals and reactive oxygen species under 'oxidative stress' conditions. The aim of this work is to develop a simple, low-cost, sensitive, and diversely applicable indirect spectrophotometric method for the determination of total antioxidant capacity of several plants. The method is based on the oxidation of antioxidants with cerium(IV) sulfate in dilute sulfuric acid at room temperature. The Ce(IV) reducing capacity of the sample is measured under carefully adjusted conditions of oxidant concentration and pH such that only antioxidants and not other organic compounds would be oxidized. The spectrophotometric determination of the remaining Ce(IV) was performed after completion of reaction with antioxidants. Quercetin and gallic acid were used as standards for flavonoids and phenolic acids, respectively, and results of antioxidant measurements were reported as trolox equivalents. The developed procedure was successfully applied to the assay of total antioxidant capacity due to simple compounds such as trolox, quercetin, gallic acid, ascorbic acid, catechin, naringin, naringenin, caffeic acid, chlorogenic acid, ferulic acid, and p-coumaric acid, and due to phenolic acids and flavonoids in the arieal parts of nettle (Urtica Dioica L.). Blank correction of significantly absorbing plant extracts at 320nm could be made with the aid of spectrophotometric titration. Plant selection was made in respect to high antioxidant content, and extraction was made with water. The proposed method was reproducible, and the trolox equivalent antioxidant capacities (TEAC coefficients) of the tested antioxidant compounds were correlated to those found by reference methods such as ABTS and CUPRAC. Since the TEAC coefficients found with the proposed method of naringin-naringenin and rutin-catechin pairs were close to each other, this Ce(IV)-based assay

  10. Comparative responsiveness of measures of pain and function after total hip replacement

    DEFF Research Database (Denmark)

    Nilsdotter, A K; Roos, Ewa M.; Westerlund, J P

    2001-01-01

    To compare the responsiveness of the Functional Assessment System (FAS), the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), and the Medical Outcomes Study 36-item Short Form (SF-36) in patients with osteoarthritis (OA) scheduled for total hip replacement....

  11. Measurement of total angular momentum values of high-lying even ...

    Indian Academy of Sciences (India)

    Spectrally resolved laser-induced fluorescence technique was used to uniquely assign total angular momentum () values to high-lying even-parity energy levels of atomic samarium. Unique value assignment was done for seven energy levels in the energy region 34,800–36,200 cm-1 , recently observed and reported in ...

  12. Measurements methods and variability assesment of the Norway spruce total leaf area. Implications for remote sensing

    Czech Academy of Sciences Publication Activity Database

    Homolová, L.; Lukeš, Petr; Malenovský, Z.; Lhotáková, Z.; Kaplan, Věroslav; Hanuš, Jan

    2013-01-01

    Roč. 27, č. 1 (2013), s. 111-121 ISSN 0931-1890 R&D Projects: GA ČR GA205/09/ 1989 Institutional support: RVO:67179843 Keywords : chlorophyll content * conversion factor * Picea abies * projected leaf area * remote sensing * total leaf area Subject RIV: EH - Ecology, Behaviour Impact factor: 1.869, year: 2013

  13. Non-destructive Measurement of Total Carotenoid Content in Processed Tomato Products

    NARCIS (Netherlands)

    Bicanic, D.; Streza, M.; Dóka, O.; Valinger, D.; Luterotti, S.; Ajtony, Zs; Kurtanjek, Z.; Dadarlat, D.

    2015-01-01

    Carotenes found in a diversity of fruits and vegetables are among important natural antioxidants. In a study described in this paper, the total carotenoid content (TCC) in seven different products derived from thermally processed tomatoes was determined using laser photoacoustic spectroscopy

  14. Relationship between Improvements in Physical Measures and Patient Satisfaction in Rehabilitation after Total Knee Arthroplasty

    Science.gov (United States)

    Nazzal, Mahmoud I.; Bashaireh, Khaldoon H.; Alomari, Mahmoud A.; Nazzal, Mohammad S.; Maayah, Mikhled F.; Mesmar, Mohammad

    2012-01-01

    The aim of this study was to examine patient satisfaction with rehabilitation after total knee arthroplasty (TKA). Fifty-six patients, aged 45-77 years, were enrolled in a post-TKA comprehensive therapy program focusing on knee strengthening and functional activities. The program lasted 3 months and was conducted for 1 h, twice a day, 5 days per…

  15. Error analysis of Dobson spectrophotometer measurements of the total ozone content

    Science.gov (United States)

    Holland, A. C.; Thomas, R. W. L.

    1975-01-01

    A study of techniques for measuring atmospheric ozone is reported. This study represents the second phase of a program designed to improve techniques for the measurement of atmospheric ozone. This phase of the program studied the sensitivity of Dobson direct sun measurements and the ozone amounts inferred from those measurements to variation in the atmospheric temperature profile. The study used the plane - parallel Monte-Carlo model developed and tested under the initial phase of this program, and a series of standard model atmospheres.

  16. Preoperative Measurement of Tibial Resection in Total Knee Arthroplasty Improves Accuracy of Postoperative Limb Alignment Restoration

    Directory of Open Access Journals (Sweden)

    Pei-Hui Wu

    2016-01-01

    Conclusions: Using conventional surgical instruments, preoperative measurement of resection thickness of the tibial plateau on radiographs could improve the accuracy of conventional surgical techniques.

  17. Is black carbon a better predictor of polycyclic aromatic hydrocarbon distribution in soils than total organic carbon?

    International Nuclear Information System (INIS)

    Agarwal, Tripti; Bucheli, Thomas D.

    2011-01-01

    Black carbon (BC) and total organic carbon (TOC) were quantified in the surface soils of Switzerland (N = 105) and Delhi (N = 36), India, to examine their relationships with contents of polycyclic aromatic hydrocarbons (PAH). BC content in Swiss (background) soils (N = 104) varied from 0.41 to 4.75 mg/g (median: 1.13 mg/g) and constituted 1-9% (median: 3%) of TOC. Indian (urban) soils had similar BC concentrations (0.37-2.05 mg/g, median: 1.19 mg/g), with relatively higher BC/TOC (6-23%, median: 13%). Similar to TOC, BC showed significant positive correlation with lighter PAH, but no correlation with heavier PAH in Swiss soils. In contrast, heavier PAH were significantly correlated only with BC in Delhi soils. It seems that TOC governs the distribution of PAH in organic matter rich background soils, while the proximity to emission sources is reflected by BC-PAH association in urban soils. - Light PAH correlated with TOC in background soils, whereas heavy PAH were associated with BC close to emission sources.

  18. Global Electric Circuit Implications of Total Current Measurements over Electrified Clouds

    Science.gov (United States)

    Mach, Douglas M.; Blakeslee, Richard J.; Bateman, Monte G.

    2009-01-01

    We determined total conduction (Wilson) currents and flash rates for 850 overflights of electrified clouds spanning regions including the Southeastern United States, the Western Atlantic Ocean, the Gulf of Mexico, Central America and adjacent oceans, Central Brazil, and the South Pacific. The overflights include storms over land and ocean, with and without lightning, and with positive and negative Wilson currents. We combined these individual storm overflight statistics with global diurnal lightning variation data from the Lightning Imaging Sensor (LIS) and Optical Transient Detector (OTD) to estimate the thunderstorm and electrified shower cloud contributions to the diurnal variation in the global electric circuit. The contributions to the global electric circuit from lightning producing clouds are estimated by taking the mean current per flash derived from the overflight data for land and ocean overflights and combining it with the global lightning rates (for land and ocean) and their diurnal variation derived from the LIS/OTD data. We estimate the contribution of non-lightning producing electrified clouds by assuming several different diurnal variations and total non-electrified storm counts to produce estimates of the total storm currents (lightning and non-lightning producing storms). The storm counts and diurnal variations are constrained so that the resultant total current diurnal variation equals the diurnal variation in the fair weather electric field (+/-15%). These assumptions, combined with the airborne and satellite data, suggest that the total mean current in the global electric circuit ranges from 2.0 to 2.7 kA, which is greater than estimates made by others using other methods.

  19. A Confirmatory Analysis of the Organ Donation Readiness Index: Measuring the Potential for Organ Donations among African Americans

    Science.gov (United States)

    Rice, Christopher; Tamburlin, Judith

    2004-01-01

    The need for transplant exceeds the number of available organs. Antigen compatible organs are particularly scarce for African Americans because of their proportionately lower rate of donations. This study presents a measure of organ donation readiness. Examination of the factor structure and a test of weak invariance were conducted on…

  20. Integration of In-Flight and Post-Flight Water Monitoring Resources in Addressing the U.S. Water Processor Assembly Total Organic Carbon (TOC) Anomaly

    Science.gov (United States)

    Straub, John E., II; McCly, J. Torin

    2011-01-01

    Beginning in June of 2010, the total organic carbon (TOC) concentration in the U.S. Water Processor Assembly (WPA) product water started to increase. A surprisingly consistent upward TOC trend was observed through weekly ISS total organic carbon analyzer (TOCA) monitoring. As TOC is a general organic compound indicator, return of water archive samples was needed to make better-informed crew health decisions on the specific compounds of concern and to aid in WPA troubleshooting. TOCA-measured TOC was more than halfway to the health-based screening limit of 3,000 g/L before archive samples were returned. Archive samples were returned on 22 Soyuz in September 2010 and on ULF5 in November of 2010. The samples were subjected to extensive analysis. Although TOC was confirmed to be elevated, somewhat surprisingly, none of the typical target compounds were detected at high levels. After some solid detective work, it was confirmed that the TOC was associated with a compound known as dimethylsilanediol (DMSD). DMSD is believed to be a breakdown product of siloxanes which are thought to be ubiquitous in the ISS atmosphere. A toxicological limit was set for DMSD and a forward plan was developed for conducting operations in the context of understanding the composition of the TOC measured in flight. This required careful consideration of existing ISS flight rules, coordination with ISS stakeholders, and development of a novel approach for the blending of inflight TOCA data with archive results to protect crew health. Among other challenges, team members had to determine how to utilize TOCA readings when making decisions about crew consumption of WPA water. This involved balancing very real concerns associated with the assumption that TOC would continue to be comprised of only DMSD. Demonstrated teamwork, multidisciplinary awareness, and innovative problem-solving were required to respond effectively to this anomaly.

  1. Model-based wear measurements in total knee arthroplasty : development and validation of novel radiographic techniques

    NARCIS (Netherlands)

    IJsseldijk, van E.A.

    2016-01-01

    The primary aim of this work was to develop novel model-based mJSW measurement methods using a 3D reconstruction and compare the accuracy and precision of these methods to conventional mJSW measurement. This thesis contributed to the development, validation and clinical application of model-based

  2. Some measurements of total electron content made with the ATS-6 radio beacon

    International Nuclear Information System (INIS)

    Davies, K.; Degenhardt, W.; Hartmann, G.K.

    1978-01-01

    The paper deals with some measurements made with the radio beacon on board the ATS-6 satellite in the American and European sectors. Measurements of the slant electron content, the Faraday content, and the plasmaspheric (or residual) content, made under different geographic and geomagnetic conditions, are discussed and compared

  3. Localized hippocampus measures are associated with Alzheimer pathology and cognition independent of total hippocampal volume.

    NARCIS (Netherlands)

    Carmichael, O.; Xie, J.; Fletcher, E.; Singh, B.; DeCarli, C.; Olde Rikkert, M.; et al.,

    2012-01-01

    Hippocampal injury in the Alzheimer's disease (AD) pathological process is region-specific and magnetic resonance imaging (MRI)-based measures of localized hippocampus (HP) atrophy are known to detect region-specific changes associated with clinical AD, but it is unclear whether these measures

  4. Localized hippocampus measures are associated with Alzheimer pathology and cognition independent of total hippocampal volume

    NARCIS (Netherlands)

    Carmichael, Owen; Xie, Jing; Fletcher, Evan; Singh, Baljeet; Decarli, Charles; A, Saradha; Abdi, Hervé; Abdul Hadi, Normi; Abdulkadir, Ahmed; Abdullah, Afnizanfaizal; Achuthan, Anusha; Adluru, Nagesh; Aggarwal, Namita; Aghajanian, Jania; Agyemang, Alex; Ahdidan, Jamila; Ahmad, Duaa; Ahmed, Shiek; Ahmed, Fareed; Ahmed, Fayeza; Akbarifar, Roshanak; Akhondi-Asl, Alireza; Aksu, Yaman; Alcauter, Sarael; Daniel, Alexander; Alin, Aylin; Alshuft, Hamza; Alvarez-Linera, Juan; Amin-Mansour, Ali; Anderson, Dallas; Anderson, Jeff; Andorn, Anne; Ang, Amma; Angersbach, Steve; Ansarian, Reza; Appaji, Abhishek; Appannah, Arti; Arfanakis, Konstantinos; Armentrout, Steven; Arrighi, Michael; Arumughababu, S. Vethanayaki; Arunagiri, Vidhya; Ashe-McNalley, Cody; Ashford, Wes; Aurelie, Le Page; Avants, Brian; Aviv, Richard; Avula, Ramesh; Richard, Edo; Schmand, Ben

    2012-01-01

    Hippocampal injury in the Alzheimer's disease (AD) pathological process is region-specific and magnetic resonance imaging (MRI)-based measures of localized hippocampus (HP) atrophy are known to detect region-specific changes associated with clinical AD, but it is unclear whether these measures

  5. Total Measurement Uncertainty (TMU) for Nondestructive Assay of Transuranic (TRU) Waste at the WRAP Facility

    International Nuclear Information System (INIS)

    WILLS, C.E.

    1999-01-01

    This report examines the contributing factors to NDA measurement uncertainty at WRAP. The significance of each factor on the TMU is analyzed, and a final method is given for determining the TMU for NDA measurements at WRAP. As more data becomes available, and WRAP gains in operational experience, this report will be reviewed semi-annually and updated as necessary

  6. Precise Measurement of the $\\bar{p}p$ Total Cross-Section in the ISR Energy Range

    CERN Multimedia

    2002-01-01

    The major aim of this experiment is the precise measurement of the antiproton-proton total cross-section in the ISR energy range, using the total-rate method. The proton-proton total cross-section is remeasured with the same method and the same apparatus, and a precision of 0.5\\% is expected for both cross-sections. The total-rate method consists in the simultaneous measurement of the total interaction rate and the ISR luminosity. This is done with a set of scintillation-counter hodoscopes covering over 99.99\\% of the solid angle, which are sensitive to over 95\\% of all interactions. In addition to these detectors, small-angle drift-tube hodoscopes are used to measure the differential elastic cross-section as a function of the momentum transfert t. The total cross-section can be measured independently by extrapolating this differential cross-section to the forward direction and invoking the optical theorem. A study of the general features of charged-particle production is performed using finely divided scinti...

  7. Measurement of parity nonconservation in the proton-proton total cross section at 800 MeV

    International Nuclear Information System (INIS)

    Bowman, J.D.

    1986-01-01

    A report is made of a measurement of parity nonconservation in the transmission of 800-MeV longitudinally polarized protons through an unpolarized, 1-m liquid-hydrogen target. The dependence of transmission on beam properties was studied to measure and to correct for systematic errors. The measured longitudinal asymmetry in the total cross section is A/sub L/ = [+2.4 +- 1.1 (statistical) +- 0.1 (systematic)] x 10 -7 . 25 refs., 2 figs

  8. Laser ablation-laser induced breakdown spectroscopy for the measurement of total elemental concentration in soils.

    Science.gov (United States)

    Pareja, Jhon; López, Sebastian; Jaramillo, Daniel; Hahn, David W; Molina, Alejandro

    2013-04-10

    The performances of traditional laser-induced breakdown spectroscopy (LIBS) and laser ablation-LIBS (LA-LIBS) were compared by quantifying the total elemental concentration of potassium in highly heterogeneous solid samples, namely soils. Calibration curves for a set of fifteen samples with a wide range of potassium concentrations were generated. The LA-LIBS approach produced a superior linear response different than the traditional LIBS scheme. The analytical response of LA-LIBS was tested with a large set of different soil samples for the quantification of the total concentration of Fe, Mn, Mg, Ca, Na, and K. Results showed an acceptable linear response for Ca, Fe, Mg, and K while poor signal responses were found for Na and Mn. Signs of remaining matrix effects for the LA-LIBS approach in the case of soil analysis were found and discussed. Finally, some improvements and possibilities for future studies toward quantitative soil analysis with the LA-LIBS technique are suggested.

  9. Measuring the Total Economic Value of State-Funded Higher Education in Iowa

    OpenAIRE

    Swenson, David A.

    2011-01-01

    This is an evaluation of the statewide total economic value of state-funded higher education in Iowa. The analysis is based on Fiscal Year 2010 final budgeted values for Iowa's three Board of Regents universities and their teaching hospital, as well as the state's 15 community colleges. Final budget year data were obtained from the respective state universities' web sites, from the Board of Regents, and from the Annual Condition of Iowa's Community Colleges, 2010, report published by the Iowa...

  10. Flexicurity as a measuring leakage protection of workers: between "social pollution" and "total security".

    Directory of Open Access Journals (Sweden)

    Calogero Massimo Cammalleri

    2012-01-01

    Full Text Available Was not the labour problem the same everywhere? The paper at­tempts to answer this question by proposing a re-interpretation of flexicurity through the comparison with the economic concepts of externalities and distortion of competition. After a methodological and epistemological premise, based on a multidisciplinary literature, the paper - crit­ically addresses the origins of flexicurity and argues that it lacks an archetypical definition, especially in the formulation of the EU Commission. Hence, the paper considers flexicurity as any balance between flexibility and security and, therefore, pro­poses ordering any set of contracts, providing the same balance and with the same regulatory framework, in “communities”. It is assumed, therefore, that communities can differ either in terms of a “protective” trade­-off, where the differential is not a surrogate measure of security, or in terms of an economic trade-off, where it is met by the provision of social insurance or security. One of these sets is called community 0 and it corresponds to undeclared work, not only illegal, but also completely devoid of security and fully flexible. After identifying from ILO, EU and constitutional sources the foundation of the “incompressibility” of rights which guarantee decent work, the paper likens decent work to a public good of general interest, in the same way as laws generally recognize the natural environment. On the basis of this comparative axiom, the paper proposes considering the dispersion of security produced by undeclared work as “un-decent” work and, therefore, as a form of “pollution”. The paper proposes, conversely, to define as a “total secure” environment one where there is no loss of se­curity and, therefore, a non-polluted environment. Because an environment can be little or very polluted, the paper proposes considering as social pollution any form, even legal, of security leakage - such as that induced by the

  11. Total deposition of cesium-137 measured in Finland during the exercise 'RESUME 95' in August 1995

    International Nuclear Information System (INIS)

    Geer, L.E. De; Vintersved, I.; Arntsing, R.

    1997-01-01

    In the exercise called 'RESUME 95' the Nuclear Detection Group from the National Defence Research Establishment in Stockholm participated with field gamma ray measurements combined with soil sampling and profile measurements. The results are presented in this report for the measurements of cesium-137. We considered the measurements of cesium-137 at the airfield the most important part of the in-situ exercise. Data was of course collected also for cesium-134 and natural radionuclides but time has not permitted a full analysis of these radionuclides. The methodology would, however, be the same as applied for cesium-137. Less attention was paid for area II and due to limited personnel resources the search exercise was not fully carried out. (au)

  12. Total deposition of cesium-137 measured in Finland during the exercise `RESUME 95` in August 1995

    Energy Technology Data Exchange (ETDEWEB)

    Geer, L.E. De; Vintersved, I.; Arntsing, R. [National Defence Research Establisment, Nuclear Detection Group, Stockholm (Sweden)

    1997-12-31

    In the exercise called `RESUME 95` the Nuclear Detection Group from the National Defence Research Establishment in Stockholm participated with field gamma ray measurements combined with soil sampling and profile measurements. The results are presented in this report for the measurements of cesium-137. We considered the measurements of cesium-137 at the airfield the most important part of the in-situ exercise. Data was of course collected also for cesium-134 and natural radionuclides but time has not permitted a full analysis of these radionuclides. The methodology would, however, be the same as applied for cesium-137. Less attention was paid for area II and due to limited personnel resources the search exercise was not fully carried out. (au).

  13. Total deposition of cesium-137 measured in Finland during the exercise `RESUME 95` in August 1995

    Energy Technology Data Exchange (ETDEWEB)

    Geer, L.E. De; Vintersved, I; Arntsing, R [National Defence Research Establisment, Nuclear Detection Group, Stockholm (Sweden)

    1998-12-31

    In the exercise called `RESUME 95` the Nuclear Detection Group from the National Defence Research Establishment in Stockholm participated with field gamma ray measurements combined with soil sampling and profile measurements. The results are presented in this report for the measurements of cesium-137. We considered the measurements of cesium-137 at the airfield the most important part of the in-situ exercise. Data was of course collected also for cesium-134 and natural radionuclides but time has not permitted a full analysis of these radionuclides. The methodology would, however, be the same as applied for cesium-137. Less attention was paid for area II and due to limited personnel resources the search exercise was not fully carried out. (au).

  14. Trimble M3 1” and South Nts-362R Total Station Angle Measurement Accuracy Analysis

    Directory of Open Access Journals (Sweden)

    Oleniacz Grzegorz

    2017-03-01

    Full Text Available The main purpose of this study was to obtain information about the actual precision of angle measurements with two instruments (Trimble M3 1 "and South NTS-362R, realizable in given measurement conditions. This object is achieved by using a simplified method of testing instruments contained in the PN-ISO 17123-3 standard [1]. This is a continuation of research described in [2], carried out on the same test base, but this time in a different, less favorable field conditions. The use of the same instrument has created an opportunity to compare and analyze the measurement results. The scope of work includes the measurement and results preparation along with statistical processing of the obtained results for both instruments.

  15. Comparison between Random Forests, Artificial Neural Networks and Gradient Boosted Machines Methods of On-Line Vis-NIR Spectroscopy Measurements of Soil Total Nitrogen and Total Carbon

    Directory of Open Access Journals (Sweden)

    Said Nawar

    2017-10-01

    Full Text Available Accurate and detailed spatial soil information about within-field variability is essential for variable-rate applications of farm resources. Soil total nitrogen (TN and total carbon (TC are important fertility parameters that can be measured with on-line (mobile visible and near infrared (vis-NIR spectroscopy. This study compares the performance of local farm scale calibrations with those based on the spiking of selected local samples from both fields into an European dataset for TN and TC estimation using three modelling techniques, namely gradient boosted machines (GBM, artificial neural networks (ANNs and random forests (RF. The on-line measurements were carried out using a mobile, fiber type, vis-NIR spectrophotometer (305–2200 nm (AgroSpec from tec5, Germany, during which soil spectra were recorded in diffuse reflectance mode from two fields in the UK. After spectra pre-processing, the entire datasets were then divided into calibration (75% and prediction (25% sets, and calibration models for TN and TC were developed using GBM, ANN and RF with leave-one-out cross-validation. Results of cross-validation showed that the effect of spiking of local samples collected from a field into an European dataset when combined with RF has resulted in the highest coefficients of determination (R2 values of 0.97 and 0.98, the lowest root mean square error (RMSE of 0.01% and 0.10%, and the highest residual prediction deviations (RPD of 5.58 and 7.54, for TN and TC, respectively. Results for laboratory and on-line predictions generally followed the same trend as for cross-validation in one field, where the spiked European dataset-based RF calibration models outperformed the corresponding GBM and ANN models. In the second field ANN has replaced RF in being the best performing. However, the local field calibrations provided lower R2 and RPD in most cases. Therefore, from a cost-effective point of view, it is recommended to adopt the spiked European dataset

  16. Total OH reactivity measurements using a new fast Gas Chromatographic Photo-Ionization Detector (GC-PID

    Directory of Open Access Journals (Sweden)

    V. Sinha

    2012-12-01

    Full Text Available The primary and most important oxidant in the atmosphere is the hydroxyl radical (OH. Currently OH sinks, particularly gas phase reactions, are poorly constrained. One way to characterize the overall sink of OH is to measure directly the ambient loss rate of OH, the total OH reactivity. To date, direct measurements of total OH reactivity have been either performed using a Laser-Induced Fluorescence (LIF system ("pump-and-probe" or "flow reactor" or the Comparative Reactivity Method (CRM with a Proton-Transfer-Reaction Mass Spectrometer (PTR-MS. Both techniques require large, complex and expensive detection systems. This study presents a feasibility assessment for CRM total OH reactivity measurements using a new detector, a Gas Chromatographic Photoionization Detector (GC-PID. Such a system is smaller, more portable, less power consuming and less expensive than other total OH reactivity measurement techniques.

    Total OH reactivity is measured by the CRM using a competitive reaction between a reagent (here pyrrole with OH alone and in the presence of atmospheric reactive molecules. The new CRM method for total OH reactivity has been tested with parallel measurements of the GC-PID and the previously validated PTR-MS as detector for the reagent pyrrole during laboratory experiments, plant chamber and boreal field studies. Excellent agreement of both detectors was found when the GC-PID was operated under optimum conditions. Time resolution (60–70 s, sensitivity (LOD 3–6 s−1 and overall uncertainty (25% in optimum conditions for total OH reactivity were similar to PTR-MS based total OH reactivity measurements. One drawback of the GC-PID system was the steady loss of sensitivity and accuracy during intensive measurements lasting several weeks, and a possible toluene interference. Generally, the GC-PID system has been shown to produce closely comparable results to the PTR-MS and thus in suitable environments (e.g. forests it

  17. Total and (n, 2n) neutron cross section measurements on 241Am

    International Nuclear Information System (INIS)

    Sage, C.

    2009-01-01

    Neutron induced reaction cross sections on 241 Am have been measured at the IRMM in Geel, Belgium, in the frame of a collaboration between the EC Joint Research Centres IRMM and ITU and French laboratories from CNRS and CEA. Raw material coming from the Atalante facility of CEA Marcoule has been transformed into suitable AmO 2 samples embedded in Al 2 O 3 and Y 2 O 3 matrices. The irradiations for the 241 Am(n, 2n) 240 Am reaction cross section measurement were carried out at the 7 MV Van de Graaff accelerator using the activation technique with quasi mono-energetic neutrons from 8 to 21 MeV produced via the D(d, n) 3 He and the T(d, n) 4 He reactions. The cross section was determined relative to the 27 Al(n, α) 24 Na standard cross section and was investigated for the first time above 15 MeV. The induced activity was measured off-line by standard γ-ray spectrometry using a high purity Ge detector. A special effort was made for the estimation of the uncertainties and the correlations between our experimental points. A different sample of the same isotope 241 Am has been measured in transmission and capture experiments in the resolved resonance region at the neutron ToF facility GELINA. The transmission measurement was performed in two campaigns, with an upgrade of the whole data acquisition system in between, followed by an investigation of its new performances. A preliminary analysis of the resonance parameters tends to confirm the recent evaluation to a higher value for the cross section at the bottom of the first resonances. A new design of C 6 D 6 detectors for capture measurements has been studied, but the data reduction and analysis of the measurement are not part of this work. (author) [fr

  18. Total ozone derived from UV spectrophotometer measurements on the NASA CV-990 aircraft for the fall 1976 latitude survey flights

    Science.gov (United States)

    Hanser, F. A.

    1977-01-01

    An ultraviolet interference filter spectrophotometer was modified to use a photodiode and was flown on latitude survey flights in the fall of 1976. Comparison with Dobson station total ozone values shows agreement between UVS and Dobson total ozone of + or - 2 percent. The procedure used to convert UVS measured ozone above the aircraft altitude to total ozone above ground level introduces an additional 2 percent deviation for very high altitude UVS ozone data. Under stable aircraft operating conditions, the UVS derived ozone values have a variability, or reproducibility, of better than + or -1 percent. The UVS data from the latitude survey flights yield a detailed latitude profile of total ozone over the Pacific Ocean during November 1976. Significant latitudinal structure in total ozone is found at the middle latitudes (30 deg to 40 deg N and S).

  19. Characteristics of Lightning within Electrified Snowfall Events using Total Lightning Measurements

    Science.gov (United States)

    Schultz, C. J.; Bruning, E. C.; Lang, T. J.; Kuhlman, K. M.

    2015-12-01

    Lightning within heavy snowfall indicates the presence of heavy snowfall rates. Most studies within the literature examine this phenomenon using ground based networks that are primarily designed for identifying cloud to ground flashes. Thus, very little study of the three dimensional structure of the lightning flashes within heavy snowfall has been accomplished. Herein, total lightning mapping arrays, interferometers and ground based networks like the National Lightning Detection Network (NLDN) are utilized to document the characteristics of these flashes, including flash size, polarity, flash initiation location and inferred charge structure. A total of six events are examined, resulting in a total of approximately 80 flashes. Both individual case studies and overall population statistics will be used to characterize flashes within this winter environment. Many of these flashes are found to initiate from tall objects like television and radio communication towers, and come to ground in multiple locations along their path, resulting in one LMA derived flash containing multiple NLDN identified flashes. Cloud-to-ground flashes of both polarities are noted within the 80 flash sample. In one case, 3 separate flashes which resulted in ground flashes of both polarities were observed coming out of the same overall charge structure. This structure exhibited a highly sloped nature in the LMA data from east to west, and both +IC and -IC components of flashes were observed by the NLDN in the same region where the flashes initiated. A decrease in flash size is noted with time in at least three of these events due to weaker updraft (compared to their summertime thunderstorm counter parts) and smaller available of supercooled liquid water as inferred through trends in radar observations. These limiting factors are hypothesized to result in slower charging rates, and smaller flash sizes with time. Several flashes also exhibit sloped structures that match reflectivity

  20. Bioimpedance index for measurement of total body water in severely malnourished children

    DEFF Research Database (Denmark)

    Girma, Tsinuel; Kæstel, Pernille; Workeneh, Netsanet

    2016-01-01

    BACKGROUND & OBJECTIVES: Restoration of body composition indicates successful management of severe acute malnutrition (SAM). Bioimpedance (BI) index (height(2)/resistance) is used to predict total body water (TBW) but its performance in SAM, especially with oedema, requires further investigation....... SUBJECTS/METHODS: Children with SAM (mid-arm circumference ...Hzs. Pre- and post-deuterium dose saliva samples were analysed using isotope-ratio mass spectrometry. TBW was regressed on H(2)/Z. Xc and R were height (H)-indexed, and Xc/H plotted against R/H. RESULTS: Thirty five children (16 non-oedematous and 19 oedematous) with median (interquartile range) age of 42...

  1. Total ozone measurement: Intercomparison of prototype New Zealand filter instrument and Dobson spectrophotometer

    Science.gov (United States)

    Basher, R. E.

    1978-01-01

    A five month intercomparison showed that the total ozone amounts of a prototype narrowband interference filter instrument were 7% less than those of a Dobson instrument for an ozone range of 0.300 to 0.500 atm cm and for airmasses less than two. The 7% bias was within the intercomparison calibration uncertainty. An airmass dependence in the Dobson instrument made the bias relationship airmass-dependent but the filter instrument's ozone values were generally constant to 2% up to an airmass of four. Long term drift in the bias was negligible.

  2. Measuring the total and baryonic mass profiles of the very massive CASSOWARY 31 strong lens

    DEFF Research Database (Denmark)

    Grillo, Claudio; Christensen, L.; Gallazzi, A.

    2013-01-01

    We investigate the total and baryonic mass distributions in deflector number 31 (CSWA 31) of the Cambridge And Sloan Survey Of Wide ARcs in the skY (CASSOWARY). We confirm spectroscopically a four-image lensing system at redshift 1.4870 with Very Large Telescope/X-shooter observations. The lensed...... find that the CSWA 31 deflector has properties suggesting it to be among the most distant and massive fossil systems studied so far. The unusually strong central dark matter dominance and the possible fossil nature of this system render it an interesting target for detailed tests of cosmological models...

  3. Outcomes of total knee arthroplasty in relation to preoperative patient-reported and radiographic measures: data from the osteoarthritis initiative.

    Science.gov (United States)

    Kahn, Timothy L; Soheili, Aydin; Schwarzkopf, Ran

    2013-12-01

    Total knee arthroplasty (TKA) is the preferred surgical treatment for end-stage osteoarthritis. However, substantial numbers of patients still experience poor outcomes. Consequently, it is important to identify which patient characteristics are predictive of outcomes in order to guide clinical decisions. Our hypothesis is that preoperative patient-reported outcome measures and radiographic measures may help to predict TKA outcomes. Using cohort data from the Osteoarthritis Initiative, we studied 172 patients who underwent TKA. For each patient, we compiled pre- and postoperative Western Ontario and McMaster University Arthritis Index (WOMAC) scores. Radiographs were measured for knee joint angles, femorotibial angles, anatomical lateral distal femoral angles, and anatomical medial proximal tibial angles; Kellgren and Lawrence (KL) grades were assigned to each compartment of the knee. All studied measurements were compared to WOMAC outcomes. Preoperative WOMAC disability, pain, and total scores were positively associated with postoperative WOMAC total scores (P = .010, P = .010, and P = .009, respectively) and were associated with improvement in WOMAC total scores (P < .001, P < .001, and P < .001, respectively). For radiographic measurements, preoperative joint angles were positively associated with improvements in postoperative WOMAC total scores (P = .044). Combined KL grades (medial and lateral compartments) were negatively correlated with postoperative WOMAC disability and pain scores (P = .045 and P = .044) and were positively correlated with improvements in WOMAC total scores (P = .001). All preoperative WOMAC scores demonstrated positive associations with postoperative WOMAC scores, while among the preoperative radiographic measurements only combined KL grades and joint angles showed any correlation with postoperative WOMAC scores. Higher preoperative KL grades and joint angles were associated with better (lower) postoperative WOMAC scores, demonstrating an

  4. Total cross section measurements with π- , Σ- and protons on nuclei and nucleons around 600 GeV/c

    International Nuclear Information System (INIS)

    Dersch, U.; Akchurin, N.; Andreev, V.A.; Atamantchouk, A.G.; Aykac, M.; Balatz, M.Y.; Bondar, N.F.; Bravar, A.; Cooper, P.S.; Dauwe, L.J.; Davidenko, G.V.; Dirkes, G.; Dolgolenko, A.G.; Dreossi, D.; Dzyubenko, G.B.; Edelstein, R.; Emediato, L.; Endler, A.M.F.; Engelfried, J.; Eschrich, I.; Escobar, C.O.; Evdokimov, A.V.; Filimonov, I.S.; Garcia, F.G.; Gaspero, M.; Gerzon, S.; Giller, I.; Golovtsov, V.L.; Goncharenko, Y.M.; Gottschalk, E.; Gouffon, P.; Grachov, O.A.; Guelmez, E.; Kangling, He; Iori, M.; Jun, S.Y.; Kamenskii, A.D.; Kaya, M.; Kilmer, J.; Kim, V.T.; Kochenda, L.M.; Koenigsmann, K.; Konorov, I.; Kozhevnikov, A.P.; Krivshich, A.G.; Krueger, H.; Kubantsev, M.A.; Kubarovsky, V.P.; Kulyavtsev, A.I.; Kuropatkin, N.P.; Kurshetsov, V.F.; Kushnirenko, A.; Kwan, S.; Lach, J.; Lamberto, A.; Landsberg, L.G.; Larin, I.; Leikin, E.M.; Yunshan, Li; Zhigang, Li; Luksys, M.; Lungov, T.; Magarrel, D.; Maleev, V.P.; Mao, D.; Chensheng, Mao; Zhenlin, Mao; Masciocchi, S.; Mathew, P.; Mattson, M.; Matveev, V.; McCliment, E.; McKenna, S.L.; Moinester, M.A.; Molchanov, V.V.; Morelos, A.; Mukhin, V.A.; Nelson, K.D.; Nemitkin, A.V.; Neoustroev, P.V.; Newsom, C.; Nilov, A.P.; Nurushev, S.B.; Ocherashvili, A.; Oleynik, G.; Onel, Y.; Ozel, E.; Ozkorucuklu, S.; Patrichev, S.; Penzo, A.; Petrenko, S.I.; Pogodin, P.; Povh, B.; Procario, M.; Prutskoi, V.A.; Ramberg, E.; Rapazzo, G.F.; Razmyslovich, B.V.; Rud, V.I.; Russ, J.; Scheglov, Y.; Schiavon, P.; Semyatchkin, V.K.; Simon, J.; Sitnikov, A.I.; Skow, D.; Smith, V.J.; Srivastava, M.; Steiner, V.; Stepanov, V.; Stutte, L.; Svoiski, M.; Terentyev, N.K.; Thomas, G.P.; Uvarov, L.N.; Vasiliev, A.N.; Vavilov, D.V.; Verebryusov, V.S.; Victorov, V.A.; Vishnyakov, V.E.; Vorobyov, A.A.; Vorwalter, K.; You, J.; Wenheng, Zhao; Shuchen, Zheng; Zukanovich-Funchal, R.

    2000-01-01

    Total cross sections for Σ - and π - on beryllium, carbon, polyethylene and copper as well as total cross sections for protons on beryllium and carbon have been measured in a broad momentum range around 600 GeV/c . These measurements were performed with a transmission technique in the SELEX hyperon-beam experiment at Fermilab. We report on results obtained for hadron-nucleus cross sections and on results for σ tot (Σ - N) and σ tot (π - N) , which were deduced from nuclear cross sections

  5. Estimating Global Seafloor Total Organic Carbon Using a Machine Learning Technique and Its Relevance to Methane Hydrates

    Science.gov (United States)

    Lee, T. R.; Wood, W. T.; Dale, J.

    2017-12-01

    Empirical and theoretical models of sub-seafloor organic matter transformation, degradation and methanogenesis require estimates of initial seafloor total organic carbon (TOC). This subsurface methane, under the appropriate geophysical and geochemical conditions may manifest as methane hydrate deposits. Despite the importance of seafloor TOC, actual observations of TOC in the world's oceans are sparse and large regions of the seafloor yet remain unmeasured. To provide an estimate in areas where observations are limited or non-existent, we have implemented interpolation techniques that rely on existing data sets. Recent geospatial analyses have provided accurate accounts of global geophysical and geochemical properties (e.g. crustal heat flow, seafloor biomass, porosity) through machine learning interpolation techniques. These techniques find correlations between the desired quantity (in this case TOC) and other quantities (predictors, e.g. bathymetry, distance from coast, etc.) that are more widely known. Predictions (with uncertainties) of seafloor TOC in regions lacking direct observations are made based on the correlations. Global distribution of seafloor TOC at 1 x 1 arc-degree resolution was estimated from a dataset of seafloor TOC compiled by Seiter et al. [2004] and a non-parametric (i.e. data-driven) machine learning algorithm, specifically k-nearest neighbors (KNN). Built-in predictor selection and a ten-fold validation technique generated statistically optimal estimates of seafloor TOC and uncertainties. In addition, inexperience was estimated. Inexperience is effectively the distance in parameter space to the single nearest neighbor, and it indicates geographic locations where future data collection would most benefit prediction accuracy. These improved geospatial estimates of TOC in data deficient areas will provide new constraints on methane production and subsequent methane hydrate accumulation.

  6. The budget between transportation and accumulation of organic carbon and total nitrogen in black soil at a sloping farmland

    International Nuclear Information System (INIS)

    Fang Huajun; Zhang Xiaoping; Liang Aizhen

    2006-01-01

    Based on the rate of soil redistribution at a sloping farmland using 137 Cs tracer technique and spatial variation of soil organic carbon (SOC) and total nitrogen (TN), the spatial distribution of SOC and TN loss and the budget between transportation and accumulation for recently 50 years was calculated. The results showed that the rate of soil redistribution ranged from -24.61 t/hm 2 /a to 33.56 t/hm 2 /a, most of study area was in medium and weakly erosion phase and accounted for 83.66%; and the area of soil deposition accounted for 15.62%; The variation of the loss of SOC and TN was consistent with that of soil redistribution, shoulder-slope had the most serious loss with the rate of 407.57 kg/hm 2 /a for SOC and 39.94 kg/hm 2 /a for TN, back-slope and summit had the secondly loss with the average rate of 244.2 kg/hm 2 /a for SOC and -20.56 kg/hm 2 /a for TN. For the whole area, relative loss of SOC and TN more than 50% accounted for 10.45% and 11.21%, respectively; The net loss of sediment in the study area was 45.54 t/a for recent 48 years, among which SOC and TN were 612.62 kg/a and 47.20 kg/a, respectively, which was 52% more than that of without consideration of the enrichment of sediment on soil organic matter. (authors)

  7. Total body composition measurements using in vivo neutron activation at the University of Washington

    International Nuclear Information System (INIS)

    Lewellen, T.L.

    1986-01-01

    The University of Washington Division of Nuclear Medicine has been using in vivo irradiation to study whole body calcium since 1969. Over 350 patients have been studied and currently five patients per week are being measured in support of research programs on bone wasting disease. (author)

  8. Measuring human remains in the field: Grid technique, total station, or MicroScribe?

    Czech Academy of Sciences Publication Activity Database

    Sládek, Vladimír; Galeta, P.; Sosna, D.

    2012-01-01

    Roč. 221, 1-3 (2012), s. 16-22 ISSN 0379-0738 Institutional support: RVO:68081766 Keywords : Excavation * Field anthropology * Human skeleton * Measuring error Subject RIV: AC - Archeology, Anthropology, Ethnology Impact factor: 2.307, year: 2012

  9. The Relative Effects of Manual Versus Automatic Exposure Control on Radiation Dose to Vital Organs in Total Hip Arthroplasty.

    Science.gov (United States)

    Harper, Katharine D; Li, Shidong; Jennings, Rachel; Amer, Kamil M; Haydel, Christopher; Ali, Sayed

    2018-01-01

    Technologic advances have reduced medical radiation exposure while maintaining image quality. The purpose of this study was to determine the effects of the presence of total hip arthroplasty implants, compared with native hips, on radiation exposure of the most radiosensitive organs when manual and automatic exposure control settings are used. Detection probes were placed at six locations (stomach, sigmoid colon, right pelvic wall, left pelvic wall, pubic symphysis, and anterior pubic skin) in a cadaver. Radiographs were obtained with the use of manual and automatic exposure control protocols, with exposures recorded. A total hip arthroplasty implant was placed in the cadaver, probe positioning was confirmed, and the radiographs were repeated, with exposure values recorded. The control probe placed at the stomach had values ranging from 0.00 mSv to 0.01 mSv in protocols with and without implants. With the manual protocol, exposures in the pelvis ranged from 0.36 mSv to 2.74 mSv in the native hip and from 0.33 mSv to 2.24 mSv after implant placement. The increases in exposure after implant placement, represented as relative risk, were as follows: stomach, 1.000; pubic symphysis, 0.818; left pelvic wall, 1.381; sigmoid colon, 1.550; right pelvic wall, 0.917; and anterior pubic skin, 1.015. With automatic exposure control, exposures in the pelvis ranged from 0.07 mSv to 0.89 mSv in the native hip and from 0.21 mSv to 1.15 mSv after implant placement. With automatic exposure control, the increases in exposure after implant placement, represented as relative risk, were as follows: stomach, 1.000; pubic symphysis, 1.292; left pelvic wall, 1.476; sigmoid colon, 2.182; right pelvic wall, 3.000; and anterior pubic skin, 1.378. The amount of radiation to which patients are exposed as a result of medical procedures or imaging, and whether exposure is associated with an increased risk of malignant transformation, are the subject of ongoing debate. We found that after insertion

  10. Measurement of organic carbon stable isotope composition of different soil types by EA-IRMS system

    International Nuclear Information System (INIS)

    Qi Biao; Ding Lingling; Cui Jiehua; Wang Yanhong

    2009-01-01

    Element analyzer-isotope ratio mass spectrometers (EA-IRMS) is a rapid and precise method for measuring stable carbon isotope. Pure CO 2 reference gas was calibrated via international standard-Urea, and the δ 13 C us PDB value of pure CO 2 is (-29.523 ± 0.0181)%. Stability and linearity of the EA-IRMS system, precision of δ 13 C measurement for samples were tested through experimental comparison. Moreover, determination method of organic carbon stable isotope in soil was based on the system. The EA-IRMS system had well linearity when ion intensity ranged from 1.0 to 7.0V, and it excelled the total linearity when the ion intensity was from 1.5 to 5.0V, and the accurate result of δ 13 C for sample analysis could be obtained with precision of 0.015%. If carbon content in sample is more than 5μg, the requirement for analyzing accurate result of δ 13 C could be achieved. The organic carbon stable isotope was measured in 18 different types soil samples, the average natural abundance of 13 C was 1.082%, and the organic carbon stable isotope composition was significantly different among different type soils. (authors)

  11. Quantitative measurement of total cerebral blood flow using 2D phase-contrast MRI and doppler ultrasound

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Keum Soo; Choi, Sun Seob; Lee, Young Il [Dong-A Univ., College of Medicine, Busan (Korea, Republic of)

    2001-12-01

    To compare of quantitative measurement of the total cerebral blood flow using two-dimensional phase-contrast MR imaging and Doppler ultrasound. In 16 volunteers (mean age, 26 years; mean body weight, 66 kg) without abnormal medical histories, two-dimensional phase-contrast MR imaging was performed at the level of the C2-3 inter vertebral disc for flow measurement of the internal carotid arteries and the vertebral arteries. Volume flow measurements using Doppler ultrasound were also performed at the internal carotid arteries 2cm above the carotid bifurcation, and at the vertebral arteries at the level of the upper pole of the thyroid gland. Flows in the four vessels measured by the two methods were compared using Wilcoxon's correlation analysis and the median score. Total cerebral blood flows were calculated by summing these four vessel flows, and mean values for the 16 volunteers were calculated. Cerebral blood flows measured by 2-D phase-contrast MR imaging and Doppler ultrasounds were 233 and 239 ml/min in the right internal carotid artery, 250 and 248 ml/min in the left internal carotid artery, 62 and 56 ml/min in the right vertebral artery, and 83 and 68 ml/min in the left vertebral artery. Correlation coefficients of the blood flows determined by the two methods were 0.48, 0.54, 0.49, and 0.62 in each vessel, while total cerebral blood flows were 628{+-}68 (range, 517 to 779) ml/min and 612{+-}79 (range, 482 to 804)ml/min, respectively. Total cerebral blood flow was easily measured using 2-D phase-contrast MR imaging and Doppler ultrasound, and the two noninvasive methods can therefore be used clinically for the measurement of total cerebral blood flow.

  12. Relationships between Personal Measurements of 'Total' Dust, Respirable, Thoracic, and Inhalable Aerosol Fractions in the Cement Production Industry.

    Science.gov (United States)

    Notø, Hilde P; Nordby, Karl-Christian; Eduard, Wijnand

    2016-05-01

    The aims of this study were to examine the relationships and establish conversion factors between 'total' dust, respirable, thoracic, and inhalable aerosol fractions measured by parallel personal sampling on workers from the production departments of cement plants. 'Total' dust in this study refers to aerosol sampled by the closed face 37-mm Millipore filter cassette. Side-by-side personal measurements of 'total' dust and respirable, thoracic, and inhalable aerosol fractions were performed on workers in 17 European and Turkish cement plants. Simple linear and mixed model regressions were used to model the associations between the samplers. The total number of personal samples collected on 141 workers was 512. Of these 8.4% were excluded leaving 469 for statistical analysis. The different aerosol fractions contained from 90 to 130 measurements and-side-by side measurements of all four aerosol fractions were collected on 72 workers.The median ratios between observed results of the respirable, 'total' dust, and inhalable fractions relative to the thoracic aerosol fractions were 0.51, 2.4, and 5.9 respectively. The ratios between the samplers were not constant over the measured concentration range and were best described by regression models. Job type, position of samplers on left or right shoulder and plant had no substantial effect on the ratios. The ratios between aerosol fractions changed with different air concentrations. Conversion models for estimation of the fractions were established. These models explained a high proportion of the variance (74-91%) indicating that they are useful for the estimation of concentrations based on measurements of a different aerosol fraction. The calculated uncertainties at most observed concentrations were below 30% which is acceptable for comparison with limit values (EN 482, 2012). The cement industry will therefore be able to predict the health related aerosol fractions from their former or future measurements of one of the

  13. Measurement of total phenolic content and antioxidant activity of aerial parts of medicinal plant Coronopus didymus.

    Science.gov (United States)

    Noreen, Hafiza; Semmar, Nabil; Farman, Muhammad; McCullagh, James S O

    2017-08-01

    To evaluate the total phenolic content and compare the antioxidant activity of various solvent extracts and fractions from the aerial parts of Coronopus didymus through various assays. Total phenolic content was determined using the Folin-Ciocalteu assay and the in vitro antioxidant activity of a number of different extracts was investigated in a dose-dependent manner with three different methods: the 2,2-diphenyl-1-picrylhydrazyl (DPPH), 2,2'-azino-bis(3-ethylbenzothiazoline-6-sulfonic acid) diammonium salt (ABTS) and ferric reducing antioxidant power (FRAP) assays. A flavone was isolated from the most active ethanolic extract with high antioxidant activity using size exclusion chromatography. IC 50 values were calculated for the DPPH and ABTS methods. The FRAP activity was assessed in terms of μM Fe (II) equivalent. The phenolic content was found to be highest in the ethanol extract (CDA Et; 47.8 mM GAE) and the lowest in the dichloromethane extract (CDA DCM; 3.13 mM GAE). The ethanol extract showed high radical scavenging activity towards DPPH and ABTS radicals with IC 50 values of (7.80 × 10 2 ) and (4.32 × 10 2 ) μg/mL, respectively. The most active ethanol extract had a FRAP value of 1921.7 μM Fe (II) equivalent. The isolated flavone F10C (5,7,4'-trihydroxy-3'-methoxy flavone) was far more effective for scavenging free radicals in the DPPH and ABTS assays with IC 50 of 43.8 and 0.08 μg/mL, than the standard trolox, with IC 50 values of 97.5 and 21.1 μg/mL, respectively. In addition, the flavone F10C and the standard ascorbic acid had FRAP values of 1621.7 and 16 038.0 μM Fe (II) equivalents, respectively. The total phenolic content of extracts in decreasing order is ethanol extract (CDA Et) > acetone extract (CDA ACE) > phenolic extract (CDA MW) > n-hexane extract (CDA nHX)> chloroform extract (CDA CHL) > dichloromethane extract (CDA DCM). The ordering of extracts in terms of antioxidant activity from highest to lowest is CDA Et

  14. The role of metrics and measurements in a software intensive total quality management environment

    Science.gov (United States)

    Daniels, Charles B.

    1992-01-01

    Paramax Space Systems began its mission as a member of the Rockwell Space Operations Company (RSOC) team which was the successful bidder on a massive operations consolidation contract for the Mission Operations Directorate (MOD) at JSC. The contract awarded to the team was the Space Transportation System Operations Contract (STSOC). Our initial challenge was to accept responsibility for a very large, highly complex and fragmented collection of software from eleven different contractors and transform it into a coherent, operational baseline. Concurrently, we had to integrate a diverse group of people from eleven different companies into a single, cohesive team. Paramax executives recognized the absolute necessity to develop a business culture based on the concept of employee involvement to execute and improve the complex process of our new environment. Our executives clearly understood that management needed to set the example and lead the way to quality improvement. The total quality management policy and the metrics used in this endeavor are presented.

  15. From misconception to a must. The measured merits of total quality management and accreditation in INAA

    International Nuclear Information System (INIS)

    Bode, P.

    1997-01-01

    Increasingly governmental bodies and industry require that supporting analytical laboratories have their quality assurance program implemented in a quality system by international standards such as derived from the ISO-25 guide. Neutron activation analysis (NAA) laboratories may have to deal with this trend too. In universities and research laboratories the need for it, and the implications of total quality management system are sometimes misconceived by unfamiliarity with the issue. The laboratory for INAA in Delft has been accredited for its quality system since 1993. Some of the tangible improvements since the introduction of quality management are presented. Four strategical considerations are given to consider the introduction of quality management at NAA laboratories, viz. with respect to the role of NAA for the validation of other methods, the role of NAA in the certification of reference materials, the preservation of knowledge and the acceptance of NAA as a respectable method. (author)

  16. Measurement of the energy dependence of the total photon-proton cross section at HERA

    Energy Technology Data Exchange (ETDEWEB)

    Abramowicz, H. [Tel Aviv Univ. (Israel). Raymond and Beverly Sackler Faculty of Exact Sciences; Univ. Coll. London (United Kingdom); Krakow Univ. of Technology (Poland). Faculty of Physics, Mathematics and Applied Computer Science; Abt, I. [Max-Planck-Institut fuer Physik, Muenchen (Germany); Adamczyk, L. [AGH-Univ. of Science and Technology, Cracow (PL). Faculty of Physics and Applied Computer Science] (and others)

    2010-10-15

    The energy dependence of the photon-proton total cross section, {sigma}{sub tot}{sup {gamma}}{sup p}, was determined from e{sup +}p scattering data collected with the ZEUS detector at HERA at three values of the center-of-mass energy, W, of the {gamma}p system in the range 194

  17. Mix ratio measurements of pozzolanic blends by Fourier transform infrared-attenuated total reflectance method

    International Nuclear Information System (INIS)

    Rebagay, T.V.; Dodd, D.A.

    1992-07-01

    The disposal of low-level radioactive liquid wastes at the Hanford Site near Richland, Washington, involves mixing the wastes with pozzolanic grout-forming solid blends. Checking the quality of each blend component and its mix ratio will ensure processibility of the blend and the long-term performance of the resulting waste grout. In earlier work at Hanford laboratories, Fourier transform infrared-transmission method (FTIR-TR) using KBr pellet was applied successfully in the analysis of blends consisting of cement, fly ash, and clays. This method involves time-consuming sample preparation resulting in slow turnaround for repetitive sampling. Because reflection methods do not require elaborate sample preparation, they have the potential to reduce turnaround analysis time. Neat samples may be examined making these methods attractive for quality control. This study investigates the capability of Fourier transform infrared-attenuated total reflectance method (FTIR-ATR) to analyze pozzolanic blends

  18. Chromium 51 EDTA/technetium 99m MDP plasma ratio to measure total skeletal function

    Energy Technology Data Exchange (ETDEWEB)

    Nisbet, A.P.; Edwards, S.; Lazarus, C.R.; Malamitsi, J.; Maisey, M.N.; Mashiter, G.D.; Winn, P.J. (Guy' s Hospital, London (UK))

    1984-08-01

    A method is described for the quantitation of total skeletal activity during bone scans. The method requires a single plasma sample only, taken at the time of imaging. The ratio of % injected dose of /sup 51/Cr EDTA to that of /sup 99/Tcsup(m) MDP is calculated from this sample following combined injection of the two radiopharmaceuticals. The /sup 51/Cr EDTA level corrects for the glomerular filtration of /sup 99/Tcsup(m) MDP. Using this method, which only requires a gamma counter, significant differences from normal controls have been shown in patients with osteomalacia, renal osteodystrophy, Paget's disease and hypercalcaemia. The method provides routine quantitative data to add to the imaging information in the bone scan.

  19. Total and free thyroxine and triiodothyronine: measurement discrepancies, particularly in inpatients.

    Science.gov (United States)

    Jonklaas, Jacqueline; Sathasivam, Anpalakan; Wang, Hong; Gu, Jianghong; Burman, Kenneth D; Soldin, Steven J

    2014-09-01

    We compared the performance of tandem mass spectrometry versus immunoassay for measuring thyroid hormones in a diverse group of inpatients and outpatients. Thyroxine (T4), triiodothyronine (T3), free thyroxine (FT4), and free triiodothyronine (FT3) were measured by liquid chromatography tandem mass spectrometry and immunoassay in 100 patients and the two assays were compared. T4 and T3 values measured by the two different assays correlated well with each other (r=0.91-0.95). However, the correlation was less good at the extremes (r=0.51-0.75). FT4 and FT3 concentrations measured by the two assays correlated less well with each other (r=0.75 and 0.50 respectively). The studied analytes had poor inverse correlation with the log-transformed TSH values (r=-0.22-0.51) in the population as a whole. The strongest correlations were seen in the groups of outpatients (r=-0.25-0.61). The weakest degree of correlation was noted in the inpatient group, with many correlations actually being positive. The worst between-assay correlation was demonstrated at low and high hormone concentrations, in the very concentration ranges where accurate assay performance is typically most clinically important. Based on the lesser susceptibility of mass spectrometry to interferences from conditions such as binding protein abnormalities, we speculate that mass spectrometry better reflects the clinical situation. In this mixed population of inpatients and outpatients, we also note failure of assays to conform to the anticipated inverse linear relationship between thyroid hormones and log-transformed TSH. Copyright © 2014 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  20. Solid phase microextraction: measurement of volatile organic compounds (VOCs) in Dhaka City air pollution.

    Science.gov (United States)

    Hussam, A; Alauddin, M; Khan, A H; Chowdhury, D; Bibi, H; Bhattacharjee, M; Sultana, S

    2002-08-01

    A solid phase microextraction (SPME) technique was applied for the sampling of volatile organic compounds (VOCs) in ambient air polluted by two stroke autorickshaw engines and automobile exhausts in Dhaka city, Bangladesh. Analysis was carried out by capillary gas chromatography (GC) and GC-mass spectrometry (MS). The methodology was tested by insitu sampling of an aromatic hydrocarbon mixture gas standard with a precision of +/-5% and an average accuracy of 1-20%. The accuracy for total VOCs concentration measurement was about 7%. VOC's in ambient air were collected by exposing the SPME fiber at four locations in Dhaka city. The chromatograms showed signature similar to that of unburned gasoline (petrol) and weathered diesel containing more than 200 organic compounds; some of these compounds were positively identified. These are normal hydrocarbons pentane (n-C5H2) through nonacosane (n-C29H60), aromatic hydrocarbons: benzene, toluene, ethylbenzene, n-propylbenzene, n-butylbenzene, 1,3,5-trimethylbenzene, xylenes, and 1-isocyanato-3-methoxybenzene. Two samples collected near an autorickshaw station contained 783000 and 1479000 microg/m3 of VOCs. In particular, the concentration of toluene was 50-100 times higher than the threshold limiting value of 2000 microg/m3. Two other samples collected on street median showed 135000 microg/m3 and 180000 microg/m3 of total VOCs. The method detection limit of the technique for most semi-volatile organic compounds was 1 microg/m3.

  1. Determining the primary cosmic ray energy from the total flux of Cherenkov light measured at the Yakutsk EAS array

    International Nuclear Information System (INIS)

    Ivanov, A. A.; Knurenko, S. P.; Sleptsov, I. E.

    2007-01-01

    We present a method for determining the energy of the primary particle that generates an extensive air shower (EAS) of comic rays based on measuring the total flux of Cherenkov light from the shower. Applying this method to Cherenkov light measurements at the Yakutsk EAS array has allowed us to construct the cosmic ray energy spectrum in the range 10 15 - 3 x 10 19 eV

  2. Spatial distribution and offshore export of total organic carbon along the eastern boundary of the Subtropical North Pacific

    Directory of Open Access Journals (Sweden)

    C.G. Castro

    2011-12-01

    Full Text Available Data collected in February, 2003, along the upper continental slope of western North America between Monterey Bay, California (37°N, 122°W, and Cabo San Lucas, Mexico (23°N, 118°W, document, for the first time, the alongshore distribution of total organic carbon (TOC. Highest TOC concentrations (>70 µM were observed for waters above the nitracline and associated with both California Current and southern surface waters. The northward advection of tropical waters in the California Undercurrent did not have any discernible impact on TOC distributions. An estimate of the average rate at which TOC in surface waters was exported offshore by Ekman transport in February 2003 was 1.73 × 103 kg C yr−1 for each meter of coastline. The offshore flux estimate is thought to be conservative with respect to the annual mean offshore flux because the offshore Ekman transport and primary production increase in late spring and early summer and the contribution of upwelling filaments has not been considered. Analysis of TOC contributions to pelagic respiration suggested that TOC accounted for 45% of the oxygen decrease in southern oxic waters. In California Current and oxygen minimum zone waters, TOC did not contribute to pelagic respiration.

  3. Comparison of planar, PET and well-counter measurements of total tumor radioactivity in a mouse xenograft model.

    Science.gov (United States)

    Green, Michael V; Seidel, Jurgen; Williams, Mark R; Wong, Karen J; Ton, Anita; Basuli, Falguni; Choyke, Peter L; Jagoda, Elaine M

    2017-10-01

    Quantitative small animal radionuclide imaging studies are often carried out with the intention of estimating the total radioactivity content of various tissues such as the radioactivity content of mouse xenograft tumors exposed to putative diagnostic or therapeutic agents. We show that for at least one specific application, positron projection imaging (PPI) and PET yield comparable estimates of absolute total tumor activity and that both of these estimates are highly correlated with direct well-counting of these same tumors. These findings further suggest that in this particular application, PPI is a far more efficient data acquisition and processing methodology than PET. Forty-one athymic mice were implanted with PC3 human prostate cancer cells transfected with prostate-specific membrane antigen (PSMA (+)) and one additional animal (for a total of 42) with a control blank vector (PSMA (-)). All animals were injected with [ 18 F] DCFPyl, a ligand for PSMA, and imaged for total tumor radioactivity with PET and PPI. The tumors were then removed, assayed by well counting for total radioactivity and the values between these methods intercompared. PET, PPI and well-counter estimates of total tumor radioactivity were highly correlated (R 2 >0.98) with regression line slopes near unity (0.95radioactivity can be measured with PET or PPI with an accuracy comparable to well counting if certain experimental and pharmacokinetic conditions are met. In this particular application, PPI is significantly more efficient than PET in making these measurements. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. [Cholinesterases in total blood measured with a semiquantitative technique, and plasma or erythrocyte cholinesterases measured with quantitative techniques].

    Science.gov (United States)

    Carmona-Fonseca, Jaime

    2007-06-01

    An equivalence model which allows comparison of blood cholinesterase values, measured by Lovibond (semiquantitative technique), and Michel, EQM, Monotest (erythrocyte and plasma cholinesterases) values measured by quantitative techniques is required. The performance of Lovibond (Edson tintometric and Limperos & Ranta techniques) were compared with quantitative techniques. The experimental design was descriptive, cross-sectional, and prospective. From a working population (18-59 years) in Valle de Aburrá and Near East of Antioquia. 827 representative samples were chosen for their lack of exposure to cholinesterase-inhibiting plaguicides and affiliated to the Social Security System. (1) 827 workers were classified by Lovibond in four categories: 821 values with 75% of cholinesterase activity or greater (categories 75, 87.5 and 100%) and 6 with cholinesterase activity smaller than 75%. (2) With each quantitative method, the mean values of erythrocyte and plasmatic cholinesterase corresponding to the four values obtained with Lovibond were statistically different to each other. (3) The mean values of each quantitative technique increased when increased the tintometric method value. (4) Lovibond classified the low enzymatic erythrocyte activity very poorly (61-73%), but the classification of the low enzymatic plasma activity was almost completely in error (94-96%). The values of erythrocyte or plasma cholinesterase were adequately estimated by both the quantitative techniques of Michel and EQM and by Lovibond, but only when the enzymatic activity is normal. Lovibond, however, had a poor capacity to designate as "low" the values that were low according to the quantitative tests.

  5. Detection of total hip arthroplasties at airport security checkpoints - how do updated security measures affect patients?

    Science.gov (United States)

    Issa, Kimona; Pierce, Todd P; Gwam, Chukwuweieke; Festa, Anthony; Scillia, Anthony J; Mont, Michael A

    2018-03-01

    There have been historical reports on the experiences of patients with total hip arthroplasty (THA) passing through standard metal detectors at airports. The purpose of this study was to analyse those who had recently passed through airport security and the incidence of: (i) triggering of the alarm; (ii) extra security searches; and (iii) perceived inconvenience. A questionnaire was given to 125 patients with a THA during a follow-up appointment. Those who had passed through airport security after January 2014 met inclusion criteria. A survey was administered that addressed the number of encounters with airport security, frequency of metal detector activation, additional screening procedures utilised, whether security officials required prosthesis documentation, and perceived inconvenience. 51 patients met inclusion criteria. 10 patients (20%) reported triggered security scanners. 4 of the 10 patients stated they had surgical hardware elsewhere in the body. 13 of the 51 patients (25%) believed that having their THA increased the inconvenience of traveling. This is different from the historical cohort with standard metal detectors which patients reported a greater incidence of alarm triggering (n = 120 of 143; p = 0.0001) and perceived inconvenience (n = 99 of 143; p = 0.0001). The percentage of patients who have THA triggering security alarms has decreased. Furthermore, the number of patients who feel that their prosthesis caused traveling inconvenience has decreased. We feel that this decrease in alarms triggered and improved perceptions about inconvenience are related to the increased usage of new technology.

  6. Total solar irradiance as measured by the SOVAP radiometer onboard PICARD

    Directory of Open Access Journals (Sweden)

    Meftah Mustapha

    2016-01-01

    Full Text Available From the SOlar VAriability PICARD (SOVAP space-based radiometer, we obtained a new time series of the total solar irradiance (TSI during Solar Cycle 24. Based on SOVAP data, we obtained that the TSI input at the top of the Earth’s atmosphere at a distance of one astronomical unit from the Sun is 1361.8 ± 2.4 W m−2 (1σ representative of the 2008 solar minimum period. From 2010 to 2014, the amplitude of the changes has been of the order of ± 0.1%, corresponding to a range of about 2.7 W m−2. To determine the TSI from SOVAP, we present here an improved instrument equation. A parameter was integrated from a theoretical analysis that highlighted the thermo-electrical non-equivalence of the radiometric cavity. From this approach, we obtained values that are lower than those previously provided with the same type of instrument. The results in this paper supersede the previous SOVAP analysis and provide the best SOVAP-based TSI-value estimate and its temporal variation.

  7. Predicting the components of the total hemispherical solar radiation from sunshine duration measurements in Lagos, Nigeria

    International Nuclear Information System (INIS)

    Maduekwe, A.A.L.; Chendo, M.A.C.

    1994-06-01

    Correlations for the city of Lagos (latitude 6.58 deg. N, longitude 3.33 deg. E) have been found between the records of bright sunshine hours and the daily and monthly components of the total hemispherical solar radiation. Four new models have been developed which include H/H 0 as a predictor in the Angstrom type models for the diffuse and beam fractions. They contain the quadratic term of the sunshine index, (n/N) and are given as follows: Q/H 0 =a+b(H/H 0 )+c(n/N)+d(n/N) 2 Q/H 0 =a+b(H/H 0 )+d(n/N) 2 ; Q/H 0 =a+b(H/H 0 )+c(n/N)+d(n/N) 2 ; Q/H 0 =a+b(H/H 0 )+d(n/N) 2 ; where Q is the diffuse or beam radiation on a horizontal plane. The statistical test carried out showed that the new equations generally improved the prediction of the beam or diffuse components from the Angstrom type equations by over 25%. (author). 21 refs, 3 tabs

  8. To total amount of activity ..... and beyond: Perspectives on measuring physical behaviour

    Directory of Open Access Journals (Sweden)

    Johannes B.J. Bussmann

    2013-07-01

    Full Text Available The aim of this paper is to describe and discuss some perspectives on definitions, constructs and outcome parameters of physical behaviour. The paper focuses on the following constructs: Physical activity & active lifestyle vs. sedentary behaviour & sedentary lifestyle; Amount of physical activity vs. amount of walking; Detailed body posture & movement data vs. overall physical activity data; Behavioural context of activities; Quantity vs. quality; Physical behaviour vs. physiological response.Subsequently, the following outcome parameters provided by data reduction procedures are discussed: Distribution of length of bouts; Variability in bout length; Time window; Intensity and intensity threshold.The overview indicates that physical behaviour is a multi-dimensional construct, and it stresses the importance and relevance of constructs and parameters other than total amount of physical activity.It is concluded that the challenge for the future will be to determine which parameters are most relevant, valid and responsive. This is a matter for physical behaviour researchers to consider, that is critical to multi-disciplinary collaboration.

  9. Ultrasound-assisted extraction for total sulphur measurement in mine tailings.

    Science.gov (United States)

    Khan, Adnan Hossain; Shang, Julie Q; Alam, Raquibul

    2012-10-15

    A sample preparation method for percentage recovery of total sulphur (%S) in reactive mine tailings based on ultrasound-assisted digestion (USAD) and inductively coupled plasma-optical emission spectroscopy (ICP-OES) was developed. The influence of various methodological factors was screened by employing a two-level and three-factor (2(3)) full factorial design and using KZK-1, a sericite schist certified reference material (CRM), to find the optimal combination of studied factors and %S. Factors such as the sonication time, temperature and acid combination were studied, with the best result identified as 20 min of sonication, 80°C temperature and 1 ml of HNO(3):1 ml of HCl, which can achieve 100% recovery for the selected CRM. Subsequently a fraction of the 2(3) full factorial design was applied to mine tailings. The percentage relative standard deviation (%RSD) for the ultrasound method is less than 3.0% for CRM and less than 6% for the mine tailings. The investigated method was verified by X-ray diffraction analysis. The USAD method compared favorably with existing methods such as hot plate assisted digestion method, X-ray fluorescence and LECO™-CNS method. Copyright © 2012 Elsevier B.V. All rights reserved.

  10. Source-intrinsic near-infrared properties of Sgr A*: Total intensity measurements

    OpenAIRE

    Witzel, G.; Eckart, A.; Bremer, M.; Zamaninasab, M.; Shahzamanian, B.; Valencia-S., M.; Schödel, R.; Karas, V.; Lenzen, R.; Marchili, N.; Sabha, N.; Garcia-Marin, M.; Buchholz, R. M.; Kunneriath, D.; Straubmeier, C.

    2012-01-01

    We present a comprehensive data description for Ks-band measurements of Sgr A*. We characterize the statistical properties of the variability of Sgr A* in the near-infrared, which we find to be consistent with a single-state process forming a power-law distribution of the flux density. We discover a linear rms-flux relation for the flux-density range up to 12 mJy on a timescale of 24 minutes. This and the power-law flux density distribution implies a phenomenological, formally non-linear stat...

  11. Measurement of the total proANP product in mammals by processing independent analysis

    DEFF Research Database (Denmark)

    Hunter, Ingrid; Rehfeld, Jens Frederik; Gøtze, Jens Peter

    2011-01-01

    (proANP) and its products irrespective of variable post-translational processing. The processing-independent assay (PIA) was developed raising mono-specific antibodies against the C-terminus of sequence 1-16 in proANP. The assay procedure included plasma extraction followed by tryptic cleavage, which...... releases the assay epitope from the N-terminal region. The PIA was tested in elderly patients with symptoms of heart failure (n=450), in pigs with acute myocardial infarction (n=21), and in normal dogs and dogs with heart failure (n=77). The epitope specificity permitted reliable measurement in man, dog...

  12. Assessment of Tandem Measurements of pH and Total Gut Transit Time in Healthy Volunteers

    OpenAIRE

    Mikolajczyk, Adam E; Watson, Sydeaka; Surma, Bonnie L; Rubin, David T

    2015-01-01

    Objectives: The variation of luminal pH and transit time in an individual is unknown, yet is necessary to interpret single measurements. This study aimed to assess the intrasubject variability of gut pH and transit time in healthy volunteers using SmartPill devices (Covidien, Minneapolis, MN). Methods: Each subject (n=10) ingested two SmartPill devices separated by 24?h. Mean pH values were calculated for 30?min after gastric emptying (AGE), before the ileocecal (BIC) valve, after the ileocec...

  13. A novel automated direct measurement method for total antioxidant capacity using a new generation, more stable ABTS radical cation.

    Science.gov (United States)

    Erel, Ozcan

    2004-04-01

    To develop a novel colorimetric and automated direct measurement method for total antioxidant capacity (TAC). A new generation, more stable, colored 2,2'-azinobis-(3-ethylbenzothiazoline-6-sulfonic acid radical cation (ABTS(*+)) was employed. The ABTS(*+) is decolorized by antioxidants according to their concentrations and antioxidant capacities. This change in color is measured as a change in absorbance at 660 nm. This process is applied to an automated analyzer and the assay is calibrated with Trolox. The novel assay is linear up to 6 mmol Trolox equivalent/l, its precision values are lower than 3%, and there is no interference from hemoglobin, bilirubin, EDTA, or citrate. The method developed is significantly correlated with the Randox- total antioxidant status (TAS) assay (r = 0.897, P total antioxidant capacity.

  14. A system for accurate on-line measurement of total gas consumption or production rates in microbioreactors

    NARCIS (Netherlands)

    van Leeuwen, Michiel; Heijnen, Joseph J.; Gardeniers, Johannes G.E.; Oudshoorn, Arthur; Noorman, Henk; Visser, Jan; van der Wielen, Luuk A.M.; van Gulik, Walter M.

    2009-01-01

    A system has been developed, based on pressure controlled gas pumping, for accurate measurement of total gas consumption or production rates in the nmol/min range, applicable for on-line monitoring of bioconversions in microbioreactors. The system was validated by carrying out a bioconversion with

  15. Use of novel fibre-coupled radioluminescence and RADPOS dosimetry systems for total scatter factor measurements in small fields

    DEFF Research Database (Denmark)

    Ploquin, N.; Kertzscher, Gustavo; Vandervoort, E.

    2015-01-01

    A dosimetry system based on Al2O3:C radioluminescence (RL), and RADPOS, a novel 4D dosimetry system using microMOSFETs, were used to measure total scatter factors, (Sc,p)fclindet, for the CyberKnife robotic radiosugery system. New Monte Carlo calculated correction factors are presented and applied...

  16. Total photoabsorption cross section on nuclei measured in energy range 0.5-2.6 GeV

    International Nuclear Information System (INIS)

    Mirazita, M.

    1998-03-01

    The total photoabsorption cross section on several nuclei has been measured in the energy range 0.5 - 2.6 GeV. Nuclear data show a significant reduction of the absorption strength with respect to the free nucleon case suggesting a shadowing effect at low energies

  17. IFCC reference measurement procedure for substance concentration determination of total carbon dioxide in blood, plasma or serum

    NARCIS (Netherlands)

    Burnett, RW; Covington, AK; Fogh-Andersen, N; Kulpmann, WR; Lewenstam, A; Mas, AHJ; VanKessel, AL; Zijlstra, WG

    A reference measurement procedure for substance concentration determination of total CO, in blood, plasma (the anticoagulant is usually heparin) or serum is described. The document covers the principle of the method, the materials and equipment needed and essential aspects of the procedure. The

  18. Migration measurement of acetabular components in cementless total hip arthroplasty; Messung der Pfannenwanderung bei zementfreien Hueftimplantaten

    Energy Technology Data Exchange (ETDEWEB)

    Eckardt, A.; Karbowski, A.; Schwitalle, M.; Vogel, J.; Boden, F.; Seeleitner, C. [Mainz Univ. (Germany). Orthopaedische Klinik und Poliklinik; Schunk, K. [Mainz Univ. (Germany). Klinik und Poliklinik fuer Radiologie; Mayrhofer, P. [Innsbruck Univ. (Austria). Inst. fuer Mathematik und Geometrie

    1998-08-01

    Migration measurements of acetabular components using a special computer aided method (EBRA = abbrevation for the German term ``Ein-Bild-Roentgenanalyse``) were performed to evaluate early results of the implants and predict aseptic loosening. Methods: Standard ap-radiographs of the pelvis were marked, specific points were digitised. Simulating the spatial situation the programme computes lengitudinal and vertical migration of the cup. 74 acetabular components in 71 patients could be studied by migration measurements. Results: 14 patients showed migration of more than 1 mm, which is the confidence limit of this method. Each of these patients showed diverse reasons for the migration, i.e. osteoporosis of the acetabular bone stock or problems concerning the surgical technique which means malposition of the cup or insufficient reaming of the bone. There were some patients with severe congenital dysplasia of the hip and in some cases the inclination angle of the cup was too great. Conclusion: The technique applied for measuring migration of acetabular components can be useful for evaluating early instability of the implant and can be helpful in detecting problems concerning the surgical technique. (orig.) [Deutsch] Mittels der Ein-Bild-Roentgenanalyse wurden Pfannenwanderungen nach Implantation von zementfreien, sphaerischen Hueftgelenkspfannen erfasst, um Praediktoren fuer die langfristige Prognose der Implantate zu evaluieren. Methoden: Nach Markierung von Referenzpunkten in den Beckenuebersichtsaufnahmen wurden diese digitalisiert, vom Programm verrechnet und die Wanderung des Implantats im Verlauf angegeben. Bei 71 Patienten wurden von 74 Pfannen ueber einen Mindestnachuntersuchungszeitraum von 12 Monaten Migrationsmessungen durchgefuehrt. Das Konfidenzintervall der Methode liegt bei <1 mm. Bei jedem dieser Patienten fanden sich Hinweise entweder auf ein schlechtes Knochenlager, auf operationsbedingte Probleme, wenn keine ausreichende Primaerstabilitaet der Pfanne

  19. Evaluation of the level of skill required of operators of a computer-assisted radiologic total lung capacity measurement system

    International Nuclear Information System (INIS)

    Mazzeo, J.

    1985-01-01

    This research was conducted to obtain information regarding the feasibility of using non-medical personnel to obtain measurements of radiologic total lung capacity (TLC). Operators from each of four groups (general undergraduates, nursing students, medical students, radiologists) differing in the amount of medical training and/or experience reading x-rays, performed each of two tasks. The first task was the measurement of radiologic TLC for a set of twenty x-rays. The second task consisted of tracing the outline of the anatomical structures that must be identified in the execution of the radiologic TLC measurement task. Data from the radiologic TLC measurement task were used to identify possible group differences in the reliability and validity of the measures. The reliability analyses were performed within the framework of Generalizability Theory. While the results are not conclusive, due to small sizes, the analyses suggest that group differences in reliability of the measures, if they exist, are small

  20. Validity of estimating the organic carbon content of basin sediment using color measurements

    International Nuclear Information System (INIS)

    Sasaki, Toshinori; Sugai, Toshihiko; Ogami, Takashi; Yanagida, Makoto; Yasue, Ken-ichi

    2010-01-01

    Psychometric lightness (L* value) measured by a colorimeter offers a rapid means of obtaining the organic carbon content of sediment. We measured peat and lacustrine sediments covering the past 300 ka - 106 samples for L* value and 197 samples for organic carbon content. L* values are highly correlated with organic carbon contents. Therefore, L* values are a convenient alternative to measuring organic carbon contents. (author)

  1. : Principles of safety measures of sports events organizers without the involvement of police

    OpenAIRE

    Buchalová, Kateřina

    2013-01-01

    Title: Principles of safety measures of sports events organizers without the involvement of police Objectives: The aim of this thesis is a description of security measures at sporting events organizers. Methods: The thesis theoretical style is focused on searching for available sources of study and research, and writing their summary comparing safety measures of the organizers. Results: This work describes the activities of the organizers of sports events and precautions that must be provided...

  2. Dosimetric methods and results of measurement for total body electron irradiation

    International Nuclear Information System (INIS)

    Feng Ningyuan; Yu Geng; Yu Zihao

    1987-01-01

    A modified 'STANFORD TSEI TECHNIQUE' e.g. dual angled gantry, 6 turntable angles and 12 fields was developed on PHILIPS SL 75-20 linear accelerator to treat mycosis fungoides. A plastic scatter screen, 5 mm in thickness was used to reduce the primary electron energy to 4 MeV in order to control treatment depth (d 80 approx.= 1.2 cm) and skin dose up to 89%. The X-ray contamination was at an acceptable level of 2%. This measurement which involved multiple dosimetric methods, showed that the distance between the scattor screen and the patient, within 10-30 cm, had no influence on PDD and the dose distribution on the body surface was reasonably homogeneous, but strongly dependent on the anatomic positions. For those sites which were located in the electron beam shadows, boosting irradiation might be necessary. The preliminary clinical trials indicated that this technique is valid and feasible

  3. Nitrate removal in stream ecosystems measured by 15N addition experiments: Total uptake

    Science.gov (United States)

    Hall, R.O.; Tank, J.L.; Sobota, D.J.; Mulholland, P.J.; O'Brien, J. M.; Dodds, W.K.; Webster, J.R.; Valett, H.M.; Poole, G.C.; Peterson, B.J.; Meyer, J.L.; McDowell, W.H.; Johnson, S.L.; Hamilton, S.K.; Grimm, N. B.; Gregory, S.V.; Dahm, Clifford N.; Cooper, L.W.; Ashkenas, L.R.; Thomas, S.M.; Sheibley, R.W.; Potter, J.D.; Niederlehner, B.R.; Johnson, L.T.; Helton, A.M.; Crenshaw, C.M.; Burgin, A.J.; Bernot, M.J.; Beaulieu, J.J.; Arangob, C.P.

    2009-01-01

    We measured uptake length of 15NO-3 in 72 streams in eight regions across the United States and Puerto Rico to develop quantitative predictive models on controls of NO-3 uptake length. As part of the Lotic Intersite Nitrogen eXperiment II project, we chose nine streams in each region corresponding to natural (reference), suburban-urban, and agricultural land uses. Study streams spanned a range of human land use to maximize variation in NO-3 concentration, geomorphology, and metabolism. We tested a causal model predicting controls on NO-3 uptake length using structural equation modeling. The model included concomitant measurements of ecosystem metabolism, hydraulic parameters, and nitrogen concentration. We compared this structural equation model to multiple regression models which included additional biotic, catchment, and riparian variables. The structural equation model explained 79% of the variation in log uptake length (S Wtot). Uptake length increased with specific discharge (Q/w) and increasing NO-3 concentrations, showing a loss in removal efficiency in streams with high NO-3 concentration. Uptake lengths shortened with increasing gross primary production, suggesting autotrophic assimilation dominated NO-3 removal. The fraction of catchment area as agriculture and suburban-urban land use weakly predicted NO-3 uptake in bivariate regression, and did improve prediction in a set of multiple regression models. Adding land use to the structural equation model showed that land use indirectly affected NO-3 uptake lengths via directly increasing both gross primary production and NO-3 concentration. Gross primary production shortened SWtot, while increasing NO-3 lengthened SWtot resulting in no net effect of land use on NO- 3 removal. ?? 2009.

  4. Coulometric precise analysis of total inorganic carbon in seawater and measurements of radiocarbon for the carbon dioxide in the atmosphere and for the total inorganic carbon in seawater

    International Nuclear Information System (INIS)

    Ishii, Masao; Inoue, Hisayuki Y.; Matsueda Hidekazu

    2000-01-01

    Climate change is one of the biggest issues on the earth, and the research on the climate system has been paid much attention today. The behavior of carbon dioxide (Co 2 ), one of the major green house gases, and its related substances within and among the atmosphere, the ocean and the land biosphere is playing a key role in regulating the climate. The ocean contains ca. 4x10 19 g of carbon, which is about 50 times of that in the atmosphere. The change in carbon cycle in the ocean is considered to have a crucial impact on the concentration of CO 2 in the atmosphere. However, little has been quantitatively known about the variability of CO 2 in the ocean and its controlling physical, chemical and biological processes. The observations of the concentration and carbon isotopic ratio of total dissolved inorganic carbon (TCO 2 ) in seawater occupy important part of the research on the behavior of carbon in the ocean. In the first part of this report, we describe the fundamental knowledge of CO 2 system in seawater and the method to precisely measure TCO 2 including sampling method, the structure and the operation of the instrument we developed, and the way to assure the quality of the data. We also present some results we obtained in the western North Pacific and the equatorial Pacific. In the second part, we report the methods to collect and treat samples for the analysis of the isotopic ratio of radio carbon ( 14 C) in the atmospheric CO 2 and TCO 2 in sea water. (author)

  5. Effectiveness of team nursing compared with total patient care on staff wellbeing when organizing nursing work in acute care wards: a systematic review.

    Science.gov (United States)

    King, Allana; Long, Lesley; Lisy, Karolina

    2015-11-01

    The organization of the work of nurses, according to recognized models of care, can have a significant impact on the wellbeing and performance of nurses and nursing teams. This review focuses on two models of nursing care delivery, namely, team and total patient care, and their effect on nurses' wellbeing. To examine the effectiveness of team nursing compared to total patient care on staff wellbeing when organizing nursing work in acute care wards. Participants were nurses working on wards in acute care hospitals.The intervention was the use of a team nursing model when organizing nursing work. The comparator was the use of a total patient care model.This review considered quantitative study designs for inclusion in the review.The outcome of interest was staff wellbeing which was measured by staff outcomes in relation to job satisfaction, turnover, absenteeism, stress levels and burnout. The search strategy aimed to find both published and unpublished studies from 1995 to April 21, 2014. Quantitative papers selected for retrieval were assessed by two independent reviewers for methodological validity prior to inclusion in the review using standardized critical appraisal instruments from the Joanna Briggs Institute. Data was extracted from papers included in the review using the standardized data extraction tool from the Joanna Briggs Institute. The data extracted included specific details about the interventions, populations, study methods and outcomes of significance to the review question and its specific objectives. Due to the heterogeneity of the included quantitative studies, meta-analysis was not possible. Results have been presented in a narrative form. The database search returned 10,067 records. Forty-three full text titles were assessed, and of these 40 were excluded, resulting in three studies being included in the review. Two of the studies were quasi experimental designs and the other was considered an uncontrolled before and after experimental study

  6. Total electron content measurements at Gauhati using 140 MHz ATS-6 transmissions

    International Nuclear Information System (INIS)

    Tyagi, T.R.; Singh, L.; Minakshi Devi; Barbara, A.K.

    1977-01-01

    The amplitude and phase of 140 MHz transmissions from geostationary satellite ATS-6 (0 0 N, 35 0 E) have been recorded at Gauhati (26.16 0 N; 91.75 0 E) for the period Nov. 1975 to Aug. 1976. The calibration technique for geostationary satellite Faraday rotation measurements suggested by Checcacci and Giorgeo has been improved and generalized. It is then utilized to remove the n ambiguity in Faraday rotation values and also to estimate the correct value of diurnal minimum Faraday rotation angle so that the recorded Faraday rotation values can be converted into electron content values. Typical diurnal variation curves have been obtained for all the months except for equinoxes when the satellite transmission was off very often due to ecliptic conditions and hence no complete diurnal curves could be obtained for these months. It has been found that though December and January behave like typical winter months, the month of November is more like an equinoctial month. Similarly, though June and July behave like typical summer months, the month of May is more or less similar to equinoxes. The characteristic features of the diurnal and seasonal behaviour of the electron content have been discussed. (author)

  7. The measurement of the total electron content applied to the observation of medium scale gravity wave

    International Nuclear Information System (INIS)

    Bertel, L.; Bertin, F.; Testud, J.

    1976-01-01

    The interpretation of the measurements of the integrated electron content in terms of gravity wave requires (1) a gravity wave model at thermospheric altitudes; (2) a gravity wave-ionization interaction model in the F-region of the ionosphere; and (3) a computing program for the resulting perturbation on the integrated electron content between the satellite and the earth station used. The gravity wave model considered in this paper takes into account the dissipative effects (viscosity, thermal conduction) which become very importanr above 250 km altitude and the effect of the base wind which is capable of affecting deeply the propagation of the waves of medium scale. Starting with this model, the domains of frequencies and the wavelength of atmospheric waves which may exist in the upper atmosphere are considered. The interaction of such waves and the ionization is examined. The theoretical results give information particularly on the selectivity of the ionospheric response to the wave passage. The deduced selectivity of the models appears to be smaller than that given by other authors who used simplified gravity wave models. The method for computing the perturbation of the of the integrated electron content introduced by the wave passage is given for a geostationary satellite. Computational results are presented for application to the case of medium scale gravity waves. (author)

  8. Sorption of organic chemicals at biogeochemical interfaces - calorimetric measurements

    Science.gov (United States)

    Krüger, J.; Lang, F.; Siemens, J.; Kaupenjohann, M.

    2009-04-01

    Biogeochemical interfaces in soil act as sorbents for organic chemicals, thereby controlling the degradation and mobility of these substances in terrestrial environments. Physicochemical properties of the organic chemicals and the sorbent determine sorptive interactions. We hypothesize that the sorption of hydrophobic organic chemicals ("R-determined" chemicals) is an entropy-driven partitioning process between the bulk aqueous phase and biogeochemical interface and that the attachment of more polar organic chemicals ("F-determined" chemicals) to mineral surfaces is due to electrostatic interactions and ligand exchange involving functional groups. In order to determine thermodynamic parameters of sorbate/sorbent interactions calorimetric titration experiments have been conducted at 20˚ C using a Nanocalorimeter (TAM III, Thermometric). Solutions of different organic substances ("R-determined" chemicals: phenanthrene, bisphenol A, "F-determined" chemicals: MCPA, bentazone) with concentrations of 100 mol l-1 were added to suspensions of pure minerals (goethite, muscovite, and kaolinite and to polygalacturonic acid (PGA) as model substance for biofilms in soil. Specific surface, porosity, N and C content, particle size and point of zero charge of the mineral were analyzed to characterize the sorbents. The obtained heat quantities for the initial injection of the organic chemicals to the goethite were 55 and 71 J for bisphenol A and phenanthrene ("R-determined representatives") and 92 and 105 J for MCPA and bentazone ("F-determined" representatives). Further experiments with muscovite, kaolinite and PGA are in progress to determine G and H of the adsorption process.

  9. 76 FR 35072 - Proposed Guidance on Stress Testing for Banking Organizations With More Than $10 Billion in Total...

    Science.gov (United States)

    2011-06-15

    ... framework should be applied at various levels in the banking organization, such as business line, portfolio... a banking organization's overall strategy and annual and planning cycles. Results should be... part of the development and maintenance of a banking organization's contingency funding planning. \\6...

  10. Leaf, branch, stand and landscape scale measurements of volatile organic compound fluxes from U. S. woodlands

    Energy Technology Data Exchange (ETDEWEB)

    Guenther, A.; Greenberg, J.; Harley, P.; Helmig, D.; Klinger, L.; Vierling, L.; Zimmerman, P. [National Center for Atmospheric Research, Boulder, CO (United States). Atmospheric Chemistry Div.; Geron, C. [Environmental Protection Agency, Research Triangle Park, NC (United States)

    1996-01-01

    Natural volatile organic compound (VOC) fluxes were measured in three U.S. woodlands. Fluxes from individual leaves and branches were estimated with enclosure techniques and used to initialize and evaluate VOC emission model estimates. Ambient measurements were used to estimate above canopy fluxes for entire stands. A total of 78 VOCs were identified, with hexenol derivatives being the most commonly observed oxygenated compounds. There was also evidence of high rates of isoprene emission and high rates of monoterpenes in some genera of trees. Model predictions of diurnal variations were within + or - 35 per cent of observed flux variations. Fluxes predicted by a recent version of a biogenic emission model were within 10 per cent to 50 per cent of observed fluxes, leading to the conclusion that existing databases can provide isoprene and monoterpene emission rate potentials within acceptable limits for the dominant plant species at these three woodland sites. 21 refs., 5 tabs., 2 figs.

  11. High mass-resolution electron-ion-ion coincidence measurements on core-excited organic molecules

    CERN Document Server

    Tokushima, T; Senba, Y; Yoshida, H; Hiraya, A

    2001-01-01

    Total electron-ion-ion coincidence measurements on core excited organic molecules have been carried out with high mass resolution by using multimode (reflectron/linear) time-of-flight mass analyzer. From the ion correlation spectra of core excited CH sub 3 OH and CD sub 3 OH, the reaction pathway to form H sub 3 sup + (D sub 3 sup +) is identified as the elimination of three H (D) atoms from the methyl group, not as the inter-group (-CH sub 3 and -OH) interactions. In a PEPIPICO spectrum of acetylacetone (CH sub 3 COCH sub 2 COCH sub 3) measured by using a reflectron TOF, correlations between ions up to mass number 70 with one-mass resolution was recorded.

  12. Comparison of planar, PET and well-counter measurements of total tumor radioactivity in a mouse xenograft model

    International Nuclear Information System (INIS)

    Green, Michael V.; Seidel, Jurgen; Williams, Mark R.; Wong, Karen J.; Ton, Anita; Basuli, Falguni; Choyke, Peter L.; Jagoda, Elaine M.

    2017-01-01

    Introduction: Quantitative small animal radionuclide imaging studies are often carried out with the intention of estimating the total radioactivity content of various tissues such as the radioactivity content of mouse xenograft tumors exposed to putative diagnostic or therapeutic agents. We show that for at least one specific application, positron projection imaging (PPI) and PET yield comparable estimates of absolute total tumor activity and that both of these estimates are highly correlated with direct well-counting of these same tumors. These findings further suggest that in this particular application, PPI is a far more efficient data acquisition and processing methodology than PET. Methods: Forty-one athymic mice were implanted with PC3 human prostate cancer cells transfected with prostate-specific membrane antigen (PSMA (+)) and one additional animal (for a total of 42) with a control blank vector (PSMA (−)). All animals were injected with [ 18 F] DCFPyl, a ligand for PSMA, and imaged for total tumor radioactivity with PET and PPI. The tumors were then removed, assayed by well counting for total radioactivity and the values between these methods intercompared. Results: PET, PPI and well-counter estimates of total tumor radioactivity were highly correlated (R 2 > 0.98) with regression line slopes near unity (0.95 < slope ≤ 1.02) and intercepts near zero (−0.001 MBq ≤ intercept ≤0.004 MBq). Conclusion: Total mouse xenograft tumor radioactivity can be measured with PET or PPI with an accuracy comparable to well counting if certain experimental and pharmacokinetic conditions are met. In this particular application, PPI is significantly more efficient than PET in making these measurements.

  13. Disjunct eddy covariance measurements of volatile organic compound fluxes using proton transfer reaction mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Taipale, R.

    2011-07-01

    Volatile organic compounds (VOCs) are emitted into the atmosphere from natural and anthropogenic sources, vegetation being the dominant source on a global scale. Some of these reactive compounds are deemed major contributors or inhibitors to aerosol particle formation and growth, thus making VOC measurements essential for current climate change research. This thesis discusses ecosystem scale VOC fluxes measured above a boreal Scots pine dominated forest in southern Finland. The flux measurements were performed using the micrometeorological disjunct eddy covariance (DEC) method combined with proton transfer reaction mass spectrometry (PTR-MS), which is an online technique for measuring VOC concentrations. The measurement, calibration, and calculation procedures developed in this work proved to be well suited to long-term VOC concentration and flux measurements with PTR-MS. A new averaging approach based on running averaged covariance functions improved the determination of the lag time between wind and concentration measurements, which is a common challenge in DEC when measuring fluxes near the detection limit. The ecosystem scale emissions of methanol, acetaldehyde, and acetone were substantial. These three oxygenated VOCs made up about half of the total emissions, with the rest comprised of monoterpenes. Contrary to the traditional assumption that monoterpene emissions from Scots pine originate mainly as evaporation from specialized storage pools, the DEC measurements indicated a significant contribution from de novo biosynthesis to the ecosystem scale monoterpene emissions. This thesis offers practical guidelines for long-term DEC measurements with PTR-MS. In particular, the new averaging approach to the lag time determination seems useful in the automation of DEC flux calculations. Seasonal variation in the monoterpene biosynthesis and the detailed structure of a revised hybrid algorithm, describing both de novo and pool emissions, should be determined in

  14. Measurement of total calcium in neurons by electron probe X-ray microanalysis.

    Science.gov (United States)

    Pivovarova, Natalia B; Andrews, S Brian

    2013-11-20

    In this article the tools, techniques, and instruments appropriate for quantitative measurements of intracellular elemental content using the technique known as electron probe microanalysis (EPMA) are described. Intramitochondrial calcium is a particular focus because of the critical role that mitochondrial calcium overload plays in neurodegenerative diseases. The method is based on the analysis of X-rays generated in an electron microscope (EM) by interaction of an electron beam with the specimen. In order to maintain the native distribution of diffusible elements in electron microscopy specimens, EPMA requires "cryofixation" of tissue followed by the preparation of ultrathin cryosections. Rapid freezing of cultured cells or organotypic slice cultures is carried out by plunge freezing in liquid ethane or by slam freezing against a cold metal block, respectively. Cryosections nominally 80 nm thick are cut dry with a diamond knife at ca. -160 °C, mounted on carbon/pioloform-coated copper grids, and cryotransferred into a cryo-EM using a specialized cryospecimen holder. After visual survey and location mapping at ≤-160 °C and low electron dose, frozen-hydrated cryosections are freeze-dried at -100 °C for ~30 min. Organelle-level images of dried cryosections are recorded, also at low dose, by means of a slow-scan CCD camera and subcellular regions of interest selected for analysis. X-rays emitted from ROIs by a stationary, focused, high-intensity electron probe are collected by an energy-dispersive X-ray (EDX) spectrometer, processed by associated electronics, and presented as an X-ray spectrum, that is, a plot of X-ray intensity vs. energy. Additional software facilitates: 1) identification of elemental components by their "characteristic" peak energies and fingerprint; and 2) quantitative analysis by extraction of peak areas/background. This paper concludes with two examples that illustrate typical EPMA applications, one in which mitochondrial calcium analysis

  15. Measurement of Elastic Scattering and of Total Cross-Section at the CERN $\\bar{p}p$ Collider

    CERN Multimedia

    2002-01-01

    The aim of the experiment is to measure elastic scattering and the total cross-section at the $\\bar{p}p$ collider. \\\\ \\\\ Up to 1983 the experimental apparatus was composed of two parts : \\item 1) Telescopes of high accuracy drift and proportional chambers and counters inserted into vertically moveable sections of the vacuum chamber ('Roman pots'), detect elastic scattering in the angular region from .5 mrad up to about 3 mrad. \\item 2) The total inelastic rate is measured with a forward/backward system of drift chambers and counter hodoscopes and the UA2 central detector covering together @= 4@p solid angle. \\end{enumerate}\\\\ \\\\ With these two set-ups, the measured value of the total cross-section confirms extrapolation with (ln s)|2 behaviour. Elastic scattering and diffraction dissociation were measured in the range .03~$<$~-t~$<$~1.6~GeV|2. \\\\ \\\\ From 1984 on, six horizontally moveable ``Roman Pots'' have been installed farther away from the intersection region (up to 100~m). Using an especially desi...

  16. Total cross section measurement of muon neutrinos on isoscalar target. Exact determination of the electroweak mixing parameter

    International Nuclear Information System (INIS)

    Pain, R.

    1987-09-01

    The work presented in this thesis is concerned with high energy muon-neutrino nucleon interactions. The experiment was performed at CERN in 1984 using the CHARM marble target-calorimeter exposed to the 160 GeV narrow band beam. The experimental analysis is based on an event-by-event classification of neutral currents (NC) and charged currents (CC) interactions and on precise measurements of neutrinos and antineutrinos fluxes. This leads to precise measurements of CC total cross-sections of neutrinos and antineutrinos between 10 and 160 GeV and of NC to CC ratios of total cross-sections of events with hadron energy greater than 4 GeV: R n eutrino and R a ntineutrino. From the measurements of R n eutrino and of the ratio of CC total cross-sections of antineutrinos and neutrinos, we obtain a high precision value of the electroweak mixing angle. Comparison of this result with those obtained in proton-antiproton collisions make it possible to derive a measurement of electroweak radiative corrections and a precise determination of ρ [fr

  17. Maximizing profit on New England organic dairy farms: an economic comparison of 4 total mixed rations for organic Holsteins and Jerseys.

    Science.gov (United States)

    Marston, S P; Clark, G W; Anderson, G W; Kersbergen, R J; Lunak, M; Marcinkowski, D P; Murphy, M R; Schwab, C G; Erickson, P S

    2011-06-01

    The objective of these experiments was to compare 4 total mixed rations fed to USDA-certified organic dairy cows in New England. Forty-eight Jersey cows from the University of New Hampshire (UNH) and 64 Holstein cows from the University of Maine (UMaine) were assigned to a 2 × 2 factorial arrangement of treatments testing the main effects of corn silage versus grass silage as the forage base and commodity concentrates versus a complete pelleted concentrate mixture. Treatment diets were fed as a total mixed ration for 8 wk during the winter and spring months of 2007, 2008, and 2009. Milk yield, component, and quality data were recorded and used to calculate the value of the milk produced for each cow. The dry matter intake (DMI) was recorded and used to calculate the average cost per cow per day of each diet. Income over feed costs were calculated for each diet using milk value and feed cost data. Feed cost and income over feed cost data were resampled using bootstrap methodology to examine potential patterns. Milk yield, milk fat and true protein concentrations, and SCC were similar among treatments. Cows at UNH fed corn silage tended to have higher DMI and lower milk urea nitrogen than did cows fed grass silage, whereas cows fed pellets had higher DMI than cows fed commodities. Cows at UNH fed commodities tended to have higher body condition scores than those fed pellets. Cows at UMaine fed commodities tended to have higher DMI than did cows fed pellets, and cows fed corn silage had lower milk urea nitrogen than did cows fed grass silage. Body weights and body condition scores were not different for cows at UMaine. Feed costs were significantly higher for corn silage diets and diets at UNH containing pellets, but not at UMaine. The calculated value of the milk and income over feed costs did not differ among treatments at either university. Bootstrap replications indicated that the corn silage with commodities diet generally had the highest feed cost at both UNH

  18. Adaption of an array spectroradiometer for total ozone column retrieval using direct solar irradiance measurements in the UV spectral range

    Science.gov (United States)

    Zuber, Ralf; Sperfeld, Peter; Riechelmann, Stefan; Nevas, Saulius; Sildoja, Meelis; Seckmeyer, Gunther

    2018-04-01

    A compact array spectroradiometer that enables precise and robust measurements of solar UV spectral direct irradiance is presented. We show that this instrument can retrieve total ozone column (TOC) accurately. The internal stray light, which is often the limiting factor for measurements in the UV spectral range and increases the uncertainty for TOC analysis, is physically reduced so that no other stray-light reduction methods, such as mathematical corrections, are necessary. The instrument has been extensively characterised at the Physikalisch-Technische Bundesanstalt (PTB) in Germany. During an international total ozone measurement intercomparison at the Izaña Atmospheric Observatory in Tenerife, the high-quality applicability of the instrument was verified with measurements of the direct solar irradiance and subsequent TOC evaluations based on the spectral data measured between 12 and 30 September 2016. The results showed deviations of the TOC of less than 1.5 % from most other instruments in most situations and not exceeding 3 % from established TOC measurement systems such as Dobson or Brewer.

  19. A new technique for online measurement of total and water-soluble copper (Cu) in coarse particulate matter (PM)

    International Nuclear Information System (INIS)

    Wang, Dongbin; Shafer, Martin M.; Schauer, James J.; Sioutas, Constantinos

    2015-01-01

    This study presents a novel system for online, field measurement of copper (Cu) in ambient coarse (2.5–10 μm) particulate matter (PM). This new system utilizes two virtual impactors combined with a modified liquid impinger (BioSampler) to collect coarse PM directly as concentrated slurry samples. The total and water-soluble Cu concentrations are subsequently measured by a copper Ion Selective Electrode (ISE). Laboratory evaluation results indicated excellent collection efficiency (over 85%) for particles in the coarse PM size ranges. In the field evaluations, very good agreements for both total and water-soluble Cu concentrations were obtained between online ISE-based monitor measurements and those analyzed by means of inductively coupled plasma mass spectrometry (ICP-MS). Moreover, the field tests indicated that the Cu monitor could achieve near-continuous operation for at least 6 consecutive days (a time resolution of 2–4 h) without obvious shortcomings. - Highlights: • A novel only PM sampling and Cu measuring technology is developed. • Very good particle collection efficiency for coarse PM is observed. • Excellent agreement is obtained between Cu ISE and offline ICP-MS measurements. • The new system can be continuously operated for at least 6 consecutive days. - A new technique for online measurements of Cu in coarse PM is described

  20. Performance-Based Measurement: Action for Organizations and HPT Accountability

    Science.gov (United States)

    Larbi-Apau, Josephine A.; Moseley, James L.

    2010-01-01

    Basic measurements and applications of six selected general but critical operational performance-based indicators--effectiveness, efficiency, productivity, profitability, return on investment, and benefit-cost ratio--are presented. With each measurement, goals and potential impact are explored. Errors, risks, limitations to measurements, and a…

  1. [Balanced scorecard for performance measurement of a nursing organization in a Korean hospital].

    Science.gov (United States)

    Hong, Yoonmi; Hwang, Kyung Ja; Kim, Mi Ja; Park, Chang Gi

    2008-02-01

    The purpose of this study was to develop a balanced scorecard (BSC) for performance measurement of a Korean hospital nursing organization and to evaluate the validity and reliability of performance measurement indicators. Two hundred fifty-nine nurses in a Korean hospital participated in a survey questionnaire that included 29-item performance evaluation indicators developed by investigators of this study based on the Kaplan and Norton's BSC (1992). Cronbach's alpha was used to test the reliability of the BSC. Exploratory and confirmatory factor analysis with a structure equation model (SEM) was applied to assess the construct validity of the BSC. Cronbach's alpha of 29 items was .948. Factor analysis of the BSC showed 5 principal components (eigen value >1.0) which explained 62.7% of the total variance, and it included a new one, community service. The SEM analysis results showed that 5 components were significant for the hospital BSC tool. High degree of reliability and validity of this BSC suggests that it may be used for performance measurements of a Korean hospital nursing organization. Future studies may consider including a balanced number of nurse managers and staff nurses in the study. Further data analysis on the relationships among factors is recommended.

  2. Latitudinal distribution of total ozone and NO[sub 2] over the Atlantic Ocean according to measurements in May 1988

    Energy Technology Data Exchange (ETDEWEB)

    Elokhov, A.S; Gruzdev, A.N. (Inst. Fiziki Atmosfery, Moscow (Russian Federation))

    1992-07-01

    Measurements of the total ozone and NO[sub 2] content conducted on board a ship in the 40 deg S - 40 deg N latitudinal belt in the Atlantic Ocean in the second half of May 1988 are reported. The main features of the latitudinal distributions of total ozone and NO[sub 2] are similar. Both distributions have minima in the equatorial zone of the Southern Hemisphere, and both the ozone and NO[sub 2] contents increase from tropical to subtropical latitudes. This increase is the strongest in the subtropical jet stream zone. The fine structure of the studied distributions is also revealed, and its relationship to stratosphere-troposphere exchange processes in the tropopause folding region is discussed. The evening total NO[sub 2] content systematically exceeds that of the morning due to diurnal variations. 20 refs.

  3. Measurement of total occlusal convergence of 3 different tooth preparations in 4 different planes by dental students.

    Science.gov (United States)

    Yoon, Stephan S; Cheong, Chan; Preisser, John; Jun, Sangho; Chang, Brian M; Wright, Robert F

    2014-08-01

    Total occlusal convergence of crown preparation is an important didactic and clinical concept in dental education. The purpose of this study was to compare the discrepancy between the total occlusal convergence of dental students' typodont crown preparations and the ideal range (4 to 10 degrees) in 3 different regions of the mouth and in 4 different planes of the teeth. The dental students of the Class of 2012 at Harvard School of Dental Medicine were asked to prepare typodont teeth for crowns on 3 different teeth, the maxillary left central incisor (ceramic), mandibular left first molar (complete metal), and mandibular left first premolar (metal ceramic), during their third year preclinical summative examination and the Comprehensive Clinical Examination in their fourth year. Eighteen students prepared 3 teeth in their third and fourth years, whereas 19 students participated only in their fourth year, for a total of 55 sets of 3 teeth. By using custom fit die bases to reproduce the position, a novel procedure of measuring each tooth was accomplished in 4 different planes: the faciolingual, mesiodistal, mesiofacial-distolingual, and mesiolingual-distofacial. The total occlusal convergence of each image was measured with a computer screen protractor. The gingival 2 mm of the axial wall was used to determine the taper of each wall. Linear mixed model analysis was used to estimate and compare the total occlusal convergences of different teeth and planes (α=.05). Bonferroni corrections were used to adjust for post hoc multiple comparisons. The mean total occlusal convergence varied by tooth and plane (2-way interaction; Pplanes; the model-predicted 99% CIs for the total occlusal convergence were as follows: faciolingual (12.7, 19.4), mesiodistal (14.0, 19.3), mesiofacial-distolingual (13,4, 19.4), and mesiolingual-distofacial (13.7, 19.1). For the central incisor, 99% CIs for the total occlusal convergence were (15.9, 24.4) for the faciolingual measurement, providing

  4. The Total Work Measured During a High Intensity Isokinetic Fatigue Test Is Associated With Anaerobic Work Capacity

    Directory of Open Access Journals (Sweden)

    Laurent Bosquet, Kenan Gouadec, Nicolas Berryman, Cyril Duclos, Vincent Gremeaux, Jean Louis Croisier

    2016-03-01

    Full Text Available The purpose of the study was to determine whether total work measured during a high intensity isokinetic fatigue test (TWFAT could be considered as a valid measure of anaerobic work capacity (AWC, such as determined by total work measured during a Wingate Anaerobic Test (TWWAnT. Twenty well-trained cyclists performed 2 randomly ordered sessions involving a high intensity isokinetic fatigue test consisting in 30 reciprocal maximal concentric contractions of knee flexors and extensors at 180°·s-1, and a Wingate Anaerobic Test. We found that TWFAT of knee extensors was largely lower than TWWAnT (4151 ± 691 vs 22313 ± 2901 J, respectively, p < 0.05, Hedge’s g = 4.27. Both measures were highly associated (r = 0.83, and the 95% limits of agreement (LoA represented 24.5% of TWWAnT. TWFAT of knee flexors (2151 ± 540 J was largely lower than TWWAnT (p < 0.05, g = 9.52. By contrast, both measures were not associated (r = 0.09, and the 95% LoA represented 31.1% of TWWAnT. Combining TWFAT of knee flexors and knee extensors into a single measure (6302 ± 818 J did not changed neither improved these observations. We still found a large difference with TWWAnT (p < 0.05, g = 5.26, a moderate association (r = 0.65 and 95% LoA representing 25.5% of TWWAnT. We concluded that TWFAT of knee extensors could be considered as a valid measure of AWC, since both measure were highly associated. However, the mean difference between both measures and their 95% LoA were too large to warrant interchangeability.

  5. Measuring Transnational Organized Crime Threats to US National Security

    Science.gov (United States)

    2016-05-26

    interests. These threats were separate from traditional regional or state-centered threats, and included such diverse issues as terrorism, mass migrations ...organizations as examples of TOC; the Sinaloa Cartel, the Yakuza, the Camorra. This conceptual framework leads to the conclusion that the best way to deal

  6. Measuring fearfulness of hens in commercial organic egg production

    DEFF Research Database (Denmark)

    Hegelund, Lene; Sørensen, Jan Tind

    2007-01-01

    To evaluate agreement between flock-based fear tests used in welfare assessments of laying hens in commercial organic farms, three tests were applied in 27 flocks of layers. Tests were performed at 35 and 55 weeks of age and were based on the concepts of 'novel object', 'sudden sound' and two dif...

  7. The Theory of Benchmarking and the Measurement of Industrial Organization

    NARCIS (Netherlands)

    Ten Raa, T.

    2006-01-01

    If more productive firms grow relatively fast, an industry performs better, even when no firm exhibits technical or efficiency change.In other words, the two well-known sources of productivity growth-technology and efficiency-can be augmented by a third one, namely the industrial organization

  8. Healing models for organizations: description, measurement, and outcomes.

    Science.gov (United States)

    Malloch, K

    2000-01-01

    Healthcare leaders are continually searching for ways to improve their ability to provide optimal healthcare services, be financially viable, and retain quality caregivers, often feeling like such goals are impossible to achieve in today's intensely competitive environment. Many healthcare leaders intuitively recognize the need for more humanistic models and the probable connection with positive patient outcomes and financial success but are hesitant to make significant changes in their organizations because of the lack of model descriptions or documented recognition of the clinical and financial advantages of humanistic models. This article describes a study that was developed in response to the increasing work in humanistic or healing environment models and the need for validation of the advantages of such models. The healthy organization model, a framework for healthcare organizations that incorporates humanistic healing values within the traditional structure, is presented as a result of the study. This model addresses the importance of optimal clinical services, financial performance, and staff satisfaction. The five research-based organizational components that form the framework are described, and key indicators of organizational effectiveness over a five-year period are presented. The resulting empirical data are strongly supportive of the healing model and reflect positive outcomes for the organization.

  9. Thermal Properties of Some Organic Liquids Using Ultrasonic Velocity Measurements

    Directory of Open Access Journals (Sweden)

    P. Ramadoss

    2011-01-01

    Full Text Available Debye temperature and thermal relaxation time has been calculated in normal and boiling temperature. Using thermal relaxation time, the heat of fusion has been calculated for nineteen organic liquids and the results throw light on the method of calculating heat of fusion.

  10. Luminosity-Independent Measurement of the Proton-Proton Total Cross Section at $\\sqrt{s}$ = 8 TeV

    CERN Document Server

    Antchev, G; Atanassov, I; Avati, V; Baechler, J.; Berardi, V; Berretti, M; Bossini, E; Bozzo, M; Bottigli, U; Brucken, E; Buzzo, A; Cafagna, F S; Calicchio, M; Catanesi, M G; Covault, C; Csanad, M; Csorgo, T; Deile, M; Doubek, M; Eggert, K; Eremin, V; Ferretti, R; Ferro, F; Fiergolski, A; Garcia, F; Giani, S; Greco, V; Grzanka, L; Heino, J; Hilden, T; Intonti, R A; Kavspar, J; Kopal, J; Kundrat, V; Kurvinen, K; Lami, S; Latino, G; Lauhakangas, R; Leszko, T; Lippmaa, E; Lokajivcek, M; Lo Vetere, M; Lucas-Rodriguez, F; Macri, M.; Maki, T; Mercadante, A; Minafra, N; Minutoli, S; Nemes, F; Niewiadomski, H; Oliveri, E; Oljemark, F; Orava, R; Oriunno, M; Osterberg, K; Palazzi, P; Prochazka, J; Quinto, M; Radermacher, E; Radicioni, E; Ravotti, F; Robutti, E; Ropelewski, L; Ruggiero, G; Saarikko, H; Santroni, A; Scribano, A; Smajek, J; Snoeys, W; Sziklai, J; Taylor, C; Turini, N; Vacek, V; Vitek, M; Welti, J; Whitmore, J; Wyszkowski, P

    2013-01-01

    TOTEM has measured the proton-proton total cross-section at $\\sqrt{s}$ = 8 TeV using a luminosity independent method. In LHC fills with dedicated beam optics, the Roman Pots have been inserted very close to the beam allowing the detection of 90% of the nuclear elastic scattering events. Simultaneously the inelastic scattering rate has been measured by the T1 and T2 Telescopes. By applying the optical theorem, the total proton-proton cross-section of (101.7 $\\pm$ 2.9)mb is determined, well in agreement with the extrapolation from lower energies. This method allows also to derive the luminosity-independent elastic and inelastic cross-sections: $\\sigma_{el}$ = (27.1 $\\pm$ 1.4)mb; $\\sigma_{inel}$ = (74.7 $\\pm$ 1.7)mb.

  11. Neutron total cross section measurements in the energy region from 47 keV to 20 MeV

    International Nuclear Information System (INIS)

    Poenitz, W.P.; Whalen, J.F.

    1983-05-01

    Neutron total cross sections were measured for 26 elements. Data were obtained in the energy range from 47 keV to 20 MeV for 11 elements in the range of light-mass fission products. Previously reported measurements for eight heavy and actinide isotopes were extended to 20 MeV. Data were also obtained for Cu (47 keV to 1.4 MeV) and for Sc, Zn, Nd, Hf, and Pt (1.8 to 20 MeV). The present work is part of a continuing effort to provide accurate neutron total cross sections for evaluations and for optical-model parameteriztions. The latter are required for the derivation of other nuclear-data information of importance to applied programs. 37 references

  12. Measurement of Total Free Iron in Soils by H2S Chemisorption and Comparison with the Citrate Bicarbonate Dithionite Method

    Directory of Open Access Journals (Sweden)

    Shui-Sheng Fan

    2016-01-01

    Full Text Available Free iron is one of the major analytical items for soil basic properties. It is also an important indicator for understanding the genesis of soil, soil classification, and soil distribution behavior. In this study, an alternative analytical method (chemisorption based on thermodynamic knowledge was proposed for measurement of total free iron oxides in soils. Several representative soil samples belonging to alfisols, ultisols, inceptisols, and entisols were collected from Taiwan and tested by the chemisorption, and the estimated total free iron oxides were compared with those measured from the traditional citrate bicarbonate dithionite (CBD method. Experimental results showed that the optimal operating temperature was found to be at 773 K and the carbon monoxide (CO is the best gaseous reagent to promote the formation of FeS. The estimated total free iron oxides for soil samples determined from the chemisorption in the presence of CO were very close to those from the CBD technique. The result of regression indicates that the estimated total free iron is strongly correlated with the CBD-Fe content (R2=0.999 in the presence of CO.

  13. SF-36 total score as a single measure of health-related quality of life: Scoping review.

    Science.gov (United States)

    Lins, Liliane; Carvalho, Fernando Martins

    2016-01-01

    According to the 36-Item Short Form Health Survey questionnaire developers, a global measure of health-related quality of life such as the "SF-36 Total/Global/Overall Score" cannot be generated from the questionnaire. However, studies keep on reporting such measure. This study aimed to evaluate the frequency and to describe some characteristics of articles reporting the SF-36 Total/Global/Overall Score in the scientific literature. The Preferred Reporting Items for Systematic Reviews and Meta-Analyses method was adapted to a scoping review. We performed searches in PubMed, Web of Science, SCOPUS, BVS, and Cochrane Library databases for articles using such scores. We found 172 articles published between 1997 and 2015; 110 (64.0%) of them were published from 2010 onwards; 30.0% appeared in journals with Impact Factor 3.00 or greater. Overall, 129 (75.0%) out of the 172 studies did not specify the method for calculating the "SF-36 Total Score"; 13 studies did not specify their methods but referred to the SF-36 developers' studies or others; and 30 articles used different strategies for calculating such score, the most frequent being arithmetic averaging of the eight SF-36 domains scores. We concluded that the "SF-36 Total/Global/Overall Score" has been increasingly reported in the scientific literature. Researchers should be aware of this procedure and of its possible impacts upon human health.

  14. Objectively measured physical environmental neighbourhood factors are not associated with accelerometer-determined total sedentary time in adults

    OpenAIRE

    Compernolle, Sofie; De Cocker, Katrien; Mackenbach, Joreintje D.; Van Nassau, Femke; Lakerveld, Jeroen; Cardon, Greet; De Bourdeaudhuij, Ilse

    2017-01-01

    Background: The physical neighbourhood environment may influence adults' sedentary behaviour. Yet, most studies examining the association between the physical neighbourhood environment and sedentary behaviour rely on self-reported data of either the physical neighbourhood environment and/or sedentary behaviour. The aim of this study was to investigate the associations between objectively measured physical environmental neighbourhood factors and accelerometer-determined total sedentary time in...

  15. Measurements of total and tropospheric ozone from IASI: comparison with correlative satellite, ground-based and ozonesonde observations

    Directory of Open Access Journals (Sweden)

    A. Boynard

    2009-08-01

    Full Text Available In this paper, we present measurements of total and tropospheric ozone, retrieved from infrared radiance spectra recorded by the Infrared Atmospheric Sounding Interferometer (IASI, which was launched on board the MetOp-A European satellite in October 2006. We compare IASI total ozone columns to Global Ozone Monitoring Experiment-2 (GOME-2 observations and ground-based measurements from the Dobson and Brewer network for one full year of observations (2008. The IASI total ozone columns are shown to be in good agreement with both GOME-2 and ground-based data, with correlation coefficients of about 0.9 and 0.85, respectively. On average, IASI ozone retrievals exhibit a positive bias of about 9 DU (3.3% compared to both GOME-2 and ground-based measurements. In addition to total ozone columns, the good spectral resolution of IASI enables the retrieval of tropospheric ozone concentrations. Comparisons of IASI tropospheric columns to 490 collocated ozone soundings available from several stations around the globe have been performed for the period of June 2007–August 2008. IASI tropospheric ozone columns compare well with sonde observations, with correlation coefficients of 0.95 and 0.77 for the [surface–6 km] and [surface–12 km] partial columns, respectively. IASI retrievals tend to overestimate the tropospheric ozone columns in comparison with ozonesonde measurements. Positive average biases of 0.15 DU (1.2% and 3 DU (11% are found for the [surface–6 km] and for the [surface–12 km] partial columns respectively.

  16. Measurement of total acid number (TAN) and TAN boiling point distribution in petroleum products by electrospray ionization mass spectrometry.

    Science.gov (United States)

    Qian, Kuangnan; Edwards, Kathleen E; Dechert, Gary J; Jaffe, Stephen B; Green, Larry A; Olmstead, William N

    2008-02-01

    We report a new method for rapid measurement of total acid number (TAN) and TAN boiling point (BP) distribution for petroleum crude and products. The technology is based on negative ion electrospray ionization mass spectrometry (ESI-MS) for selective ionization of petroleum acid and quantification of acid structures and molecular weight distributions. A chip-based nanoelectrospray system enables microscale (boiling point distributions of TAN values can be calculated from the composition. The rapid measurement of TAN BP distributions by ESI is demonstrated for a series of high-TAN crudes and distillation cuts. TAN values determined by the technique agree well with those by the titration method. The distributed properties compare favorably with those measured by distillation and measurement of TAN of corresponding cuts.

  17. The measurement of antiproton-proton total cross sections and small-angle elastic scattering at low momentum

    International Nuclear Information System (INIS)

    Linssen, L.H.A.J.

    1986-01-01

    In this thesis two low-momentum antiproton-proton (anti pp) experiments are described. The first one is a set of 24 high statistics anti pp total cross section measurements as a function of the incoming antiproton momentum between p=388 MeV/c and p=599 MeV/c. These measurements simultaneously yield the charge exchange cross section (anti pp → anti nn). The second one comprises two high statistics anti pp small-angle elastic scattering measurements at p=233 MeV/c and p=272 MeV/c. The measurements were carried out using the high quality antiproton beam extracted from the Low Energy Antiproton Ring (LEAR) at CERN. The physics motivation for these experiments is a search for anti pp resonances or bound states on one hand, and a detailed study of the anti pp interaction on the other hand. (orig.)

  18. Porous Silicon Antibody Microarrays for Quantitative Analysis: Measurement of Free and Total PSA in Clinical Plasma Samples

    Science.gov (United States)

    Tojo, Axel; Malm, Johan; Marko-Varga, György; Lilja, Hans; Laurell, Thomas

    2014-01-01

    The antibody microarrays have become widespread, but their use for quantitative analyses in clinical samples has not yet been established. We investigated an immunoassay based on nanoporous silicon antibody microarrays for quantification of total prostate-specific-antigen (PSA) in 80 clinical plasma samples, and provide quantitative data from a duplex microarray assay that simultaneously quantifies free and total PSA in plasma. To further develop the assay the porous silicon chips was placed into a standard 96-well microtiter plate for higher throughput analysis. The samples analyzed by this quantitative microarray were 80 plasma samples obtained from men undergoing clinical PSA testing (dynamic range: 0.14-44ng/ml, LOD: 0.14ng/ml). The second dataset, measuring free PSA (dynamic range: 0.40-74.9ng/ml, LOD: 0.47ng/ml) and total PSA (dynamic range: 0.87-295ng/ml, LOD: 0.76ng/ml), was also obtained from the clinical routine. The reference for the quantification was a commercially available assay, the ProStatus PSA Free/Total DELFIA. In an analysis of 80 plasma samples the microarray platform performs well across the range of total PSA levels. This assay might have the potential to substitute for the large-scale microtiter plate format in diagnostic applications. The duplex assay paves the way for a future quantitative multiplex assay, which analyses several prostate cancer biomarkers simultaneously. PMID:22921878

  19. Effect of surface plasmon polaritons on the sensitivity of refractive index measurement using total internal reflection method

    International Nuclear Information System (INIS)

    Roshan Entezar, S.

    2015-01-01

    The phase difference between two p-polarized and s-polarized plane waves which are reflected under total internal reflection from the base of a prism with a thin metal coating is studied. Typically such a quantity can be used to measure the refractive index of a test material using the total internal reflection method. It is shown that due to the excitation of surface plasmon polaritons at the interface between the tested dielectric material and the thin metal layer, the p-polarized light experiences a large phase shift which enlarges the phase difference between the p-polarized and the s-polarized waves. As a result, the sensitivity of refractive index measurement increases and the error in determining the refractive index decreases. - Highlights: • Phase difference of totally internally reflected p and s polarized beams is studied. • Excitation of the surface wave increases the phase shift of the p-polarized light. • The sensitivity of refractive index measurement increases by using a coated prism. • The error in determining the refractive index decreases using the coated prism

  20. The migration of femoral components after total hip replacement surgery: accuracy and precision of software-aided measurements

    International Nuclear Information System (INIS)

    Decking, J.; Schuetz, U.; Decking, R.; Puhl, W.

    2003-01-01

    Objective: To assess the accuracy and precision of a software-aided system to measure migration of femoral components after total hip replacement (THR) on digitised radiographs. Design and patients: Subsidence and varus-valgus tilt of THR stems within the femur were measured on digitised anteroposterior pelvic radiographs. The measuring software (UMA, GEMED, Germany) relies on bony landmarks and comparability parameters of two consecutive radiographs. Its accuracy and precision were calculated by comparing it with the gold standard in migration measurements, radiostereometric analysis (RSA). Radiographs and corresponding RSA measurements were performed in 60 patients (38-69 years) following cementless THR surgery. Results and conclusions: The UMA software measured the subsidence of the stems with an accuracy of ±2.5 mm and varus-valgus tilt with an accuracy of ±1.8 (95% confidence interval). A good interobserver and intraobserver reliability was calculated with Cronbach's alpha ranging from 0.86 to 0.97. Measuring the subsidence of THR stems within the femur is an important parameter in the diagnosis of implant loosening. Software systems such as UMA improve the accuracy of migration measurements and are easy to use on routinely performed radiographs of operated hip joints. (orig.)

  1. Anthropological characteristics, internal organs measurements, and food consumption of Indonesian people, 1989-1993

    International Nuclear Information System (INIS)

    Sugiarto, C.; Bangun, M.; Singh, A.; Yazir, Y.; Alrasyid, H.; Hutagalung, H.

    1998-01-01

    This study has been conducted to obtain, assess and interpret data on morphological, anatomical, chemical and metabolic characteristics of Indonesian population of all ages for establishing an Indonesian Reference Man. The paper presents age and sex specific data on physical anthropometric measurements, and on weights and dimensions of internal organs of normal and healthy Indonesian people. In addition, the content of selected elements in main organs and foodstuff, and the data of daily food consumption of well nourished individuals in three different regions of Indonesia are also presented. Approximately 804 people of all ages were measured to obtain the physical/anthropometric data. The people chosen were from 3 Indonesian regions representing the middle class socioeconomic population. The average body weight and total body height of the age group 20-39 years were found to be 53.5 kg (range: 40-70 kg) and 160.4 cm (range: 147.3-179.8 cm) for males and 48.9 kg (range: 32.7-79.5 kg) and 150.9 cm (range: 141.8-167.3 cm) for females. The weights and dimensions of internal organs data were collected in Jakarta from about 155 sudden death victims. The weight of most male organs was generally about 1% to 19% larger than those of females. However, the female thyroid was 5.6% larger dm the males. The age specific food consumption were obtained in three regions of Indonesia. The content of elements in the selected foodstuffs are also included in this report. The results show that rice is consumed three times a day by most subjects. Milk and eggs are widely consumed and the intake tends to be higher in the younger age groups. Among the meat group, beef is the most popular and consumed with the highest frequency, followed by chicken both in popularity and quantity consumed. Vegetables, particularly the colored vegetables, are used daily in high amounts. (author)

  2. Carbono orgânico e nitrogênio total do solo e suas relações com os espaçamentos de plantio de cafeeiro Soil organic carbon and total nitrogen as related with coffee spacing

    Directory of Open Access Journals (Sweden)

    Otacílio José Passos Rangel

    2008-10-01

    L. trees and tree rows. The experiment was carried out from 1992 to 2004 on an experimental farm of EPAMIG, in Machado (Minas Gerais State, Brazil. The treatments consisted of the combination of four distances between tree rows (2.0; 2.5; 3.0 and 3.5 m, three in-row distances (0.5; 0.75 and 1.0 m and two management systems of crop residues (interline - IL and canopy projection - CP, totaling 24 treatments, arranged randomly in the field in blocks, in 4x3x2 factorial design, with three replications. The soil organic carbon (OC and total nitrogen (TN contents were measured, apart from the OC/TN ratio. In samples collected in IL, the OC and TN contents were higher than those measured in CP. The cropping spacing influenced the OC contents; highest values were verified when distance between rows was 3.5 m and in-row distances 0.75 and 0.5 m, in the 0-0.05 m layer. Higher accumulation of plant residues, low soil disruption, and, consequently, higher contents of organic matter favors more OC and TN in the IL. Deforestation and coffee cropping for 11 years resulted in decreasing OC contents from 26 % to 38 %, in IL and CP, respectively, and an average reduction of 25 % for TN.

  3. Intercomparison of the comparative reactivity method (CRM) and pump-probe technique for measuring total OH reactivity in an urban environment

    Science.gov (United States)

    Hansen, R. F.; Blocquet, M.; Schoemaecker, C.; Léonardis, T.; Locoge, N.; Fittschen, C.; Hanoune, B.; Stevens, P. S.; Sinha, V.; Dusanter, S.

    2015-10-01

    The investigation of hydroxyl radical (OH) chemistry during intensive field campaigns has led to the development of several techniques dedicated to ambient measurements of total OH reactivity, which is the inverse of the OH lifetime. Three techniques are currently used during field campaigns, including the total OH loss rate method, the pump-probe method, and the comparative reactivity method. However, no formal intercomparison of these techniques has been published so far, and there is a need to ensure that measurements of total OH reactivity are consistent among the different techniques. An intercomparison of two OH reactivity instruments, one based on the comparative reactivity method (CRM) and the other based on the pump-probe method, was performed in October 2012 in a NOx-rich environment, which is known to be challenging for the CRM technique. This study presents an extensive description of the two instruments, the CRM instrument from Mines Douai (MD-CRM) and the pump-probe instrument from the University of Lille (UL-FAGE), and highlights instrumental issues associated with the two techniques. It was found that the CRM instrument used in this study underestimates ambient OH reactivity by approximately 20 % due to the photolysis of volatile organic compounds (VOCs) inside the sampling reactor; this value is dependent on the position of the lamp within the reactor. However, this issue can easily be fixed, and the photolysis of VOCs was successfully reduced to a negligible level after this intercomparison campaign. The UL-FAGE instrument may also underestimate ambient OH reactivity due to the difficulty to accurately measure the instrumental zero. It was found that the measurements are likely biased by approximately 2 s-1, due to impurities in humid zero air. Two weeks of ambient sampling indicate that the measurements performed by the two OH reactivity instruments are in agreement, within the measurement uncertainties for each instrument, for NOx mixing ratios

  4. Vertical distribution of soil extractable organic C and N contents and total C and N stocks in 78-year-old tree plantations in subtropical Australia.

    Science.gov (United States)

    Zhou, Xiaoqi; Dong, Haibo; Lan, Zhongming; Bacon, Gary; Hao, Yanbin; Chen, Chengrong

    2017-10-01

    Few studies have focused on the effects of long-term forest plantations on the soil profile of carbon (C) and nitrogen (N) stocks. In this study, we selected 78-year-old tree plantations that included three coniferous tree species (i.e., slash pine, hoop pine and kauri pine) and a Eucalyptus species in subtropical Australia. We measured soil extractable organic C (EOC) and N (EON) contents and total C and N stocks under different tree species on the forest floor and along a soil profile to 100 cm depth. The results showed that Eucalyptus had significantly higher soil EOC contents (3.3 Mg ha -1 ) than the other tree species (EOC of 1.9-2.3 Mg ha -1 ) and had significantly higher EON (156 kg ha -1 ) contents than slash pine (107 kg ha -1 ). Eucalyptus had significantly higher soil C (58.9 Mg ha -1 ) and N (2.03 Mg ha -1 ) stocks than the other tree species (22.3-27.6 Mg C ha -1 and 0.71-1.23 Mg N ha -1 ) at 0-100 cm depth. There were no differences in soil C stocks at the 0-100 cm depth among the coniferous tree species. Forest floor C stocks had stronger effects on mineral soil total N stocks than fine root biomass, whereas fine root biomass exerted stronger effects on soil total C stocks at the 0-100 cm depth than forest floor C and N stocks. Our results addressed large differences in soil C and N stocks under different tree species, which can provide useful information for local forest management practices in this region.

  5. Measures for organizations engaged in a knowledge economy

    OpenAIRE

    Rodgers, Waymond; Housel, Thomas J.

    2009-01-01

    The article of record as published may be found at http://dx.doi.org/10.1108/14691930910977770 Purpose - The financial reporting practices of modern day organizations operating in a knowledge-based economy will eventually change as intangible assets increasingly become such organizations’ most valuable assets. Financial reports need to be supported by intangible performance metrics, in order to ensure that the reports are rigorously interpreted and applied, and if any issue...

  6. Measuring total mercury due to small-scale gold mining activities to determine community vulnerability in Cihonje, Central Java, Indonesia.

    Science.gov (United States)

    Sari, Mega M; Inoue, Takanobu; Matsumoto, Yoshitaka; Yokota, Kuriko

    2016-01-01

    This research is comparative study of gold mining and non-gold mining areas, using four community vulnerability indicators. Vulnerability indicators are exposure degree, contamination rate, chronic, and acute toxicity. Each indicator used different samples, such as wastewater from gold mining process, river water from Tajum river, human hair samples, and health questionnaire. This research used cold vapor atomic absorption spectrometry to determine total mercury concentration. The result showed that concentration of total mercury was 2,420 times than the maximum content of mercury permitted in wastewater based on the Indonesian regulation. Moreover, the mercury concentration in river water reached 685 ng/l, exceeding the quality threshold standards of the World Health Organization (WHO). The mercury concentration in hair samples obtained from the people living in the research location was considered to identify the health quality level of the people or as a chronic toxicity indicator. The highest mercury concentration--i.e. 17 ng/mg, was found in the gold mining respondents. Therefore, based on the total mercury concentration in the four indicators, the community in the gold mining area were more vulnerable to mercury than communities in non-gold mining areas. It was concluded that the community in gold mining area was more vulnerable to mercury contamination than the community in non-gold mining area.

  7. Think the way to measure the Earth Radiation Budget and the Total Solar Irradiance with a small satellites constellation

    Science.gov (United States)

    Meftah, M.; Keckhut, P.; Damé, L.; Bekki, S.; Sarkissian, A.; Hauchecorne, A.

    2018-05-01

    Within the past decade, satellites constellations have become possible and practical. One of the interest to use a satellites constellation is to measure the true Earth Radiation Imbalance, which is a crucial quantity for testing climate models and for predicting the future course of global warming. This measurement presents a high interest because the 2001-2010 decade has not shown the accelerating pace of global warming that most models predict, despite the fact that the greenhouse-gas radiative forcing continues to rise. All estimates (ocean heat content and top of atmosphere) show that over the past decade the Earth radiation imbalance ranges between 0.5 to 1W-2. Up to now, the Earth radiation imbalance has not been measured directly. The only way to measure the imbalance with sufficient accuracy is to measure both the incoming solar radiations (total solar irradiance) and the outgoing terrestrial radiations (top of atmosphere outgoing longwave radiations and shortwave radiations) onboard the same satellite, and ideally, with the same instrument. The incoming solar radiations and the outgoing terrestrial radiations are of nearly equal magnitude of the order of 340.5W-2. The objective is to measure these quantities over time by using differential Sun-Earth measurements (to counter calibration errors) with an accuracy better than 0.05Wm-2 at 1σ. It is also necessary to have redundant instruments to track aging in space in order to measure during a decade and to measure the global diurnal cycle with a dozen satellites. Solar irradiance and Earth Radiation Budget (SERB) is a potential first in orbit demonstration satellite. The SERB nano-satellite aims to measure on the same platform the different components of the Earth radiation budget and the total solar irradiance. Instrumental payloads (solar radiometer and Earth radiometers) can acquire the technical maturity for the future large missions (constellation that insure global measurement cover) by flying in a

  8. Investigation into the relationship between body surface area and total body potassium using Monte Carlo and measurement

    Energy Technology Data Exchange (ETDEWEB)

    Rogers, J.A. [Medical Physics and Imaging, Queen Elizabeth Hospital, Birmingham (United Kingdom)]. E-mail: jane.rogers@university-b.wmids.nhs.uk; Blake-James, M. [School of Physics and Astronomy, University of Birmingham, Birmingham (United Kingdom); Green, S.; Beddoe, A.H. [Medical Physics and Imaging, Queen Elizabeth Hospital, Birmingham (United Kingdom)

    2002-03-07

    The use of body surface area (BSA) as a means of indexing chemotherapy doses is widespread even though the value of this practice is uncertain. In principle, the body cell mass (BCM) more closely represents the body's metabolic size and this is investigated here as an alternative to BSA; since 98% of body potassium is intracellular the derivation of total body potassium (TBK) via the measurement of {sup 40}K in a whole body counter (WBC) will provide a useful normalizing index for metabolic size, potentially avoiding toxicity and underdosing. The Queen Elizabeth Hospital WBC has been used in this study, initially involving single geometrical phantoms and then combinations of these to simulate human body habitus. Monte Carlo N-particle (MCNP) codes were constructed to model the phantoms and simulate the measurements made in the WBC. Efficiency corrections were derived by comparing measurement and modelled data for each detector separately. A method of modelling a person in the WBC as a series of ellipsoids was developed. Twenty-four normal males and 24 females were measured for their {sup 40}K emissions. Individual MCNP codes were constructed for each volunteer and the results used in conjunction with the measurements to derive TBK, correcting for body habitus effects and detector efficiencies. An estimate of the component of error arising from sources other than counting statistics was included by analysing data from the measurement of phantoms. The total residual errors (expressed as coefficients of variation) for males and females were 10.1% and 8.5% respectively. The measurement components were determined to be 2.4% and 2.5%, implying that the biological components were 9.8% and 8.1% respectively. These results suggest that the use of BSA for indexing chemotherapy doses is likely to give rise to clinically significant under- or overdosing. (author)

  9. 78 FR 59791 - Annual Company-Run Stress Tests at Banking Organizations With Total Consolidated Assets of More...

    Science.gov (United States)

    2013-09-30

    ... bank on its Consolidated Financial Statements for Bank Holding Companies (FR Y-9C) or Consolidated... companies with $50 billion or more in total consolidated assets and any non-bank financial companies... with total consolidated assets of $50 billion or more and nonbank financial companies supervised by the...

  10. Technical Note: Precise quantitative measurements of total dissolved inorganic carbon from small amounts of seawater using a gas chromatographic system

    Directory of Open Access Journals (Sweden)

    T. Hansen

    2013-10-01

    Full Text Available Total dissolved inorganic carbon (CT is one of the most frequently measured parameters used to calculate the partial pressure of carbon dioxide in seawater. Its determination has become increasingly important because of the rising interest in the biological effects of ocean acidification. Coulometric and infrared detection methods are currently favored in order to precisely quantify CT. These methods however are not sufficiently validated for CT measurements of biological experiments manipulating seawater carbonate chemistry with an extended CT measurement range (~1250–2400 μmol kg–1 compared to natural open ocean seawater (~1950–2200 μmol kg−1. The requirement of total sample amounts between 0.1–1 L seawater in the coulometric- and infrared detection methods potentially exclude their use for experiments working with much smaller volumes. Additionally, precise CT analytics become difficult with high amounts of biomass (e.g., phytoplankton cultures or even impossible in the presence of planktonic calcifiers without sample pre-filtration. Filtration however, can alter CT concentration through gas exchange induced by high pressure. Addressing these problems, we present precise quantification of CT using a small, basic and inexpensive gas chromatograph as a CT analyzer. Our technique is able to provide a repeatability of ±3.1 μmol kg−1, given by the pooled standard deviation over a CT range typically applied in acidification experiments. 200 μL of sample is required to perform the actual CT measurement. The total sample amount needed is 12 mL. Moreover, we show that sample filtration is applicable with only minor alteration of the CT. The method is simple, reliable and with low cumulative material costs. Hence, it is potentially attractive for all researchers experimentally manipulating the seawater carbonate system.

  11. Measurement of Selected Organic Trace Gases During TRACE-P

    Science.gov (United States)

    Atlas, Elliot

    2004-01-01

    Major goals of the TRACE-P mission were: 1) to investigate the chemical composition of radiatively important gases, aerosols, and their precursors in the Asian outflow over the western Pacific, and 2) to describe and understand the chemical evolution of the Asian outflow as it is transported and mixed into the global troposphere. The research performed as part of this proposal addressed these major goals with a study of the organic chemical composition of gases in the TRACE-P region. This work was a close collaboration with the Blake/Rowland research group at UC-Irvine, and they have provided a separate report for their funded effort.

  12. Flow analysis methods for the direct ultra-violet spectrophotometric measurement of nitrate and total nitrogen in freshwaters

    Energy Technology Data Exchange (ETDEWEB)

    Gentle, Brady S.; Ellis, Peter S.; Grace, Michael R. [Water Studies Centre, School of Chemistry, Monash University, Victoria 3800 (Australia); McKelvie, Ian D., E-mail: iandm@unimelb.edu.au [School of Chemistry, University of Melbourne, Victoria 3010 (Australia); School of Geography, Earth and Environmental Sciences, University of Plymouth, Drake Circus, Plymouth PL4 8AA (United Kingdom)

    2011-10-17

    Highlights: {yields} Second derivative UV spectrophotometry has been used to determine nitrate and total N using flow analysis techniques. {yields} A simple flow system with a single-reflection flow-through cell was used for the UV measurement of nitrate. {yields} Total N was determined after on-line UV photooxidation with alkaline peroxodisulfate. {yields} Analyses carried out using the developed flow systems show a high degree of agreement with comparative analyses. {yields} This method requires no colorimetric reagents and eliminates the requirement for a toxic cadmium reduction column. - Abstract: Second derivative ultra-violet spectrophotometric methods are described for the measurement of nitrate and total nitrogen in freshwaters using flow analysis techniques. A simple flow system consisting of a peristaltic pump and a single-reflection flow-through cell was used for the measurement of nitrate. Quantification of total nitrogen using alkaline peroxodisulfate photo-digestion was achieved by incorporating an ultra-violet photo-reactor, a hollow-fibre filter and a debubbler into the flow system. The nitrate system featured a limit of detection of 0.04 mg N L{sup -1}, 0.4%RSD (1 mg N L{sup -1} as nitrate, n = 10), a coefficient of determination (R{sup 2}) of 0.9995 over the calibration range 0.0-2.0 mg N L{sup -1}, and a data acquisition time of 1.5 s per spectrum. The total nitrogen system featured a limit of detection of 0.05 mg N L{sup -1}, 1%RSD (1 mg N L{sup -1} as ammonium chloride, n = 10), a coefficient of determination of 0.9989 over the calibration range 0.0-2.0 mg N L{sup -1}, and a throughput of 5 sample h{sup -1} measured in triplicate. Digestions of five model nitrogen compounds returned recoveries of >88%. Determinations carried out using the developed systems show a high degree of agreement with data obtained using reference methods. These methods require no colorimetric reagents and eliminate the requirement for a toxic cadmium reduction column

  13. Flow analysis methods for the direct ultra-violet spectrophotometric measurement of nitrate and total nitrogen in freshwaters

    International Nuclear Information System (INIS)

    Gentle, Brady S.; Ellis, Peter S.; Grace, Michael R.; McKelvie, Ian D.

    2011-01-01

    Highlights: → Second derivative UV spectrophotometry has been used to determine nitrate and total N using flow analysis techniques. → A simple flow system with a single-reflection flow-through cell was used for the UV measurement of nitrate. → Total N was determined after on-line UV photooxidation with alkaline peroxodisulfate. → Analyses carried out using the developed flow systems show a high degree of agreement with comparative analyses. → This method requires no colorimetric reagents and eliminates the requirement for a toxic cadmium reduction column. - Abstract: Second derivative ultra-violet spectrophotometric methods are described for the measurement of nitrate and total nitrogen in freshwaters using flow analysis techniques. A simple flow system consisting of a peristaltic pump and a single-reflection flow-through cell was used for the measurement of nitrate. Quantification of total nitrogen using alkaline peroxodisulfate photo-digestion was achieved by incorporating an ultra-violet photo-reactor, a hollow-fibre filter and a debubbler into the flow system. The nitrate system featured a limit of detection of 0.04 mg N L -1 , 0.4%RSD (1 mg N L -1 as nitrate, n = 10), a coefficient of determination (R 2 ) of 0.9995 over the calibration range 0.0-2.0 mg N L -1 , and a data acquisition time of 1.5 s per spectrum. The total nitrogen system featured a limit of detection of 0.05 mg N L -1 , 1%RSD (1 mg N L -1 as ammonium chloride, n = 10), a coefficient of determination of 0.9989 over the calibration range 0.0-2.0 mg N L -1 , and a throughput of 5 sample h -1 measured in triplicate. Digestions of five model nitrogen compounds returned recoveries of >88%. Determinations carried out using the developed systems show a high degree of agreement with data obtained using reference methods. These methods require no colorimetric reagents and eliminate the requirement for a toxic cadmium reduction column. The overlap of chloride and nitrate spectra in seawater is

  14. Measurements of the total-body potassium contents. Application of reference value with the whole-body counter

    Energy Technology Data Exchange (ETDEWEB)

    Yamamoto, Tetsuo [Chiba Univ. (Japan). Inst. for Training Radiological Technicians; Saegusa, Kenji; Arimizu, Noboru; Kuniyasu, Yoshio; Itoh, Hisao

    2001-08-01

    The total-body potassium contents were measured in 405 healthy volunteers and 186 patients with whole body counter in Chiba University Hospital. The total-body potassium contents was expressed by the reference value (R value). The R value was calculated as measured potassium contents (g) divided by the body surface area (m{sup 2}) and adjusted by age and sex of healthy persons. The R value was 100.65{+-}9.22% in 405 healthy volunteers. Those of each disease were as follows: liver cirrhosis; 94.24{+-}11.22%, chronic hepatitis; 95.74{+-}11.24%, hyperthyroidism; 99.37{+-}10.8%, periodic paralysis; 82.0{+-}9.01%, Barter's syndrome; 93.99{+-}9.86%, myasthenia gravis; 97.34{+-}6.42% and hypo-potassemia; 90.64{+-}11.76%, respectively. The R values of other diseases such as uterine cancer, breast cancer, anemia, hypertension were 97.78{+-}11.5%, 99.22{+-}8.88%, 96.64{+-}12.73%, 98.5{+-}9.63% respectively. Fourteen patients showed especially lower R values under 75%. These were 1 liver cirrhosis, 3 hypertension, 1 diabetes mellitus, 3 hypo-potassemia, 1 periodic paralysis, 2 Barter's syndrome, 2 chemical poisoning, and 1 breast cancer. Follow-up study was performed in some patients with the lower R values. The result of follow-up study showed that there was a relationship between improvement of symptoms and increase of total body potassium contents. (author)

  15. Measurement of activated rCBF by the 133Xe inhalation technique: a comparison of total versus partial curve analysis

    International Nuclear Information System (INIS)

    Leli, D.A.; Katholi, C.R.; Hazelrig, J.B.; Falgout, J.C.; Hannay, H.J.; Wilson, E.M.; Wills, E.L.; Halsey, J.H. Jr.

    1985-01-01

    An initial assessment of the differential sensitivity of total versus partial curve analysis in estimating task related focal changes in cortical blood flow measured by the 133 Xe inhalation technique was accomplished by comparing the patterns during the performance of two sensorimotor tasks by normal subjects. The validity of these patterns was evaluated by comparing them to the activation patterns expected from activation studies with the intra-arterial technique and the patterns expected from neuropsychological research literature. Subjects were 10 young adult nonsmoking healthy male volunteers. They were administered two tasks having identical sensory and cognitive components but different response requirements (oral versus manual). The regional activation patterns produced by the tasks varied with the method of curve analysis. The activation produced by the two tasks was very similar to that predicted from the research literature only for total curve analysis. To the extent that the predictions are correct, these data suggest that the 133 Xe inhalation technique is more sensitive to regional flow changes when flow parameters are estimated from the total head curve. The utility of the total head curve analysis will be strengthened if similar sensitivity is demonstrated in future studies assessing normal subjects and patients with neurological and psychiatric disorders

  16. Warming and organic matter sources impact the proportion of dissolved to total activities in marine extracellular enzymatic rates

    KAUST Repository

    Baltar, Federico; Moran, Xose Anxelu G.; Lø nborg, Christian

    2017-01-01

    Extracellular enzymatic activities (EEAs) are the rate-limiting step in the degradation of organic matter. Extracellular enzymes can be found associated to cells or dissolved in the surrounding water. The proportion of cell-free EEA constitutes

  17. Association Mapping of Total Carotenoids in Diverse Soybean Genotypes Based on Leaf Extracts and High-Throughput Canopy Spectral Reflectance Measurements.

    Directory of Open Access Journals (Sweden)

    Arun Prabhu Dhanapal

    Full Text Available Carotenoids are organic pigments that are produced predominantly by photosynthetic organisms and provide antioxidant activity to a wide variety of plants, animals, bacteria, and fungi. The carotenoid biosynthetic pathway is highly conserved in plants and occurs mostly in chromoplasts and chloroplasts. Leaf carotenoids play important photoprotective roles and targeted selection for leaf carotenoids may offer avenues to improve abiotic stress tolerance. A collection of 332 soybean [Glycine max (L. Merr.] genotypes was grown in two years and total leaf carotenoid content was determined using three different methods. The first method was based on extraction and spectrophotometric determination of carotenoid content (eCaro in leaf tissue, whereas the other two methods were derived from high-throughput canopy spectral reflectance measurements using wavelet transformed reflectance spectra (tCaro and a spectral reflectance index (iCaro. An association mapping approach was employed using 31,253 single nucleotide polymorphisms (SNPs to identify SNPs associated with total carotenoid content using a mixed linear model based on data from two growing seasons. A total of 28 SNPs showed a significant association with total carotenoid content in at least one of the three approaches. These 28 SNPs likely tagged 14 putative loci for carotenoid content. Six putative loci were identified using eCaro, five loci with tCaro, and nine loci with iCaro. Three of these putative loci were detected by all three carotenoid determination methods. All but four putative loci were located near a known carotenoid-related gene. These results showed that carotenoid markers can be identified in soybean using extract-based as well as by high-throughput canopy spectral reflectance-based approaches, demonstrating the utility of field-based canopy spectral reflectance phenotypes for association mapping.

  18. Relationships among Contrasting Measurements of Microbial Dynamics in Pasture and Organic Farm Soils

    International Nuclear Information System (INIS)

    Edenborn, S.L; Sexstone, A.J; Sutanto, Y; Chapman, J.A

    2011-01-01

    Soil bacteria exhibit short-term variations in community structure, providing an indication of anthropogenic disturbances. In this study, microbial biomass carbon (MBC), potentially mineralizable nitrogen (PMN), community level physiological profiling (CLPP), and culture-dependent DGGE (CD DGGE) fingerprinting of the 16 S r RNA gene were used to compare microbial communities in organic farm and pasture soils subjected to differing agronomic treatments. Correlation analyses revealed significant relationships between MBC, PMN, and data derived from microbial community analyses. All measures separated soil types but varied in their ability to distinguish among treatments within a soil type. Overall, MBC, PMN, and CLPP were most responsive to compost and manure amendments, while CD DGGE resolved differences in legume cropping and inorganic fertilization. The results support the hypothesis that culturable soil bacteria are a responsive fraction of the total microbial community, sensitive to agronomic perturbations and amenable to further studies aimed at linking community structure with soil functions.

  19. IMU-based Real-time Pose Measurement system for Anterior Pelvic Plane in Total Hip Replacement Surgeries.

    Science.gov (United States)

    Zhe Cao; Shaojie Su; Hao Tang; Yixin Zhou; Zhihua Wang; Hong Chen

    2017-07-01

    With the aging of population, the number of Total Hip Replacement Surgeries (THR) increased year by year. In THR, inaccurate position of the implanted prosthesis may lead to the failure of the operation. In order to reduce the failure rate and acquire the real-time pose of Anterior Pelvic Plane (APP), we propose a measurement system in this paper. The measurement system includes two parts: Initial Pose Measurement Instrument (IPMI) and Real-time Pose Measurement Instrument (RPMI). IPMI is used to acquire the initial pose of the APP, and RPMI is used to estimate the real-time pose of the APP. Both are composed of an Inertial Measurement Unit (IMU) and magnetometer sensors. To estimate the attitude of the measurement system, the Extended Kalman Filter (EKF) is adopted in this paper. The real-time pose of the APP could be acquired together with the algorithm designed in the paper. The experiment results show that the Root Mean Square Error (RMSE) is within 1.6 degrees, which meets the requirement of THR operations.

  20. A comparison between patient recall and concurrent measurement of preoperative quality of life outcome in total hip arthroplasty.

    Science.gov (United States)

    Howell, Jonathan; Xu, Min; Duncan, Clive P; Masri, Bassam A; Garbuz, Donald S

    2008-09-01

    The objective is to evaluate the reliability of patients' recall of preoperative pain and function during the immediate postoperation period after total hip arthroplasty. A prospective cohort of 104 patients completed a survey about their quality of life before operation, and recalled preoperative status at 3 days, 6 weeks, and 12 weeks after operation. Quality of life was measured by the Western Ontario and McMaster University Osteoarthritis Index, the Oxford-12 hip score, and the 12-item Short-Form score. The intraclass correlation coefficient and Spearman correlation coefficient were used to compare preoperative quality of life scores to the scores recalled. The reliability of recall remained high up to 3 months postoperation. Patients are able to accurately recall their preoperative function for up to 3 months after total hip arthroplasty.

  1. Design of a bolometer for total-energy measurement of the linear coherent light source pulsed X-ray laser

    International Nuclear Information System (INIS)

    Friedrich, S.; Li, L.; Ott, L.L.; Kolgani, Rajeswari M.; Yong, G.J.; Ali, Z.A.; Drury, O.B.; Ables, E.; Bionta, R.M.

    2006-01-01

    We are developing a cryogenic bolometer to measure the total energy of the linear coherent light source (LCLS) free electron X-ray laser to be built at the Stanford Linear Accelerator Center. The laser will produce ultrabright X-ray pulses in the energy range between 0.8 and 8 keV with ∼10 12 photons per ∼200 fs pulse at a repeat interval of 8 ms, and will be accompanied by a halo of spontaneous undulator radiation. The bolometer is designed to determine the total energy of each laser pulse to within (1- x ) Sr x MnO 3 sensor array at the metal-insulator transition, where the composition x is adjusted to produce the desired transition temperature. We discuss design considerations and material choices, and present numerical simulations of the thermal response

  2. Quantitative nanoscale surface voltage measurement on organic semiconductor blends

    International Nuclear Information System (INIS)

    Cuenat, Alexandre; Muñiz-Piniella, Andrés; Muñoz-Rojo, Miguel; Murphy, Craig E; Tsoi, Wing C

    2012-01-01

    We report on the validation of a method based on Kelvin probe force microscopy (KPFM) able to measure the different phases and the relative work function of polymer blend heterojunctions at the nanoscale. The method does not necessitate complex ultra-high vacuum setup. The quantitative information that can be extracted from the topography and the Kelvin probe measurements is critically analysed. Surface voltage difference can be observed at the nanoscale on poly(3-hexyl-thiophene):[6,6]-phenyl-C61-butyric acid methyl ester (P3HT:PCBM) blends and dependence on the annealing condition and the regio-regularity of P3HT is observed. (paper)

  3. A Study on Education and the Organization of School Libraries in the Perspective of Total Quality Management

    Directory of Open Access Journals (Sweden)

    Cengiz Aslan

    2017-06-01

    Full Text Available The arrangement of enriched school libraries (Z Library established by the Republic of Turkey Ministry of National Education are analyzed in the perspective of total quality management in terms of institutionalization and supervision, goals and productivity.

  4. Experiment to measure total cross sections, differential cross sections and polarization effects in pp elastic scattering at RHIC

    International Nuclear Information System (INIS)

    Guryn, W.

    1998-02-01

    The authors are describing an experiment to study proton-proton (pp) elastic scattering experiment at the Relativistic Heavy Ion Collider (RHIC). Using both polarized and unpolarized beams, the experiment will study pp elastic scattering from √s = 50 GeV to √s = 500 GeV in two kinematical regions. In the Coulomb Nuclear Interference (CNI) region, 0.0005 2 , they will measure and study the s dependence of the total and elastic cross sections, σ tot and σ el ; the ratio of the real to the imaginary part of the forward elastic scattering amplitude, ρ; and the nuclear slope parameter of the pp elastic scattering, b. In the medium |t|-region, |t| 2 , they plan to study the evolution of the dip structure with s, as observed at ISR in the differential elastic cross section, dσ el /dt, and the s and |t| dependence of b. With the polarized beams the following can be measured: the difference in the total cross sections as function of initial transverse spin states Δσ T , the analyzing power, A N , and the transverse spin correlation parameter A NN . The behavior of the analyzing power A N at RHIC energies in the dip region of dσ el /dt, where a pronounced structure was found at fixed-target experiments will be studied. The relation of pp elastic scattering to the beam polarization measurement at RHIC is also discussed

  5. The Profile of a School and Measurement of a Multi-School Organization Change Program.

    Science.gov (United States)

    Feitler, Fred C.

    Modern organization theory and research from business and industry predicts that schools which change toward the Likert participative group organizations will increase productivity. This paper reports interventions of a one-year organization development program carried out with 12 schools and the change results measured by the Profile of a School.…

  6. Current Practices of Measuring and Reference Range Reporting of Free and Total Testosterone in the United States.

    Science.gov (United States)

    Le, Margaret; Flores, David; May, Danica; Gourley, Eric; Nangia, Ajay K

    2016-05-01

    The evaluation and management of male hypogonadism should be based on symptoms and on serum testosterone levels. Diagnostically this relies on accurate testing and reference values. Our objective was to define the distribution of reference values and assays for free and total testosterone by clinical laboratories in the United States. Upper and lower reference values, assay methodology and source of published reference ranges were obtained from laboratories across the country. A standardized survey was reviewed with laboratory staff via telephone. Descriptive statistics were used to tabulate results. We surveyed a total of 120 laboratories in 47 states. Total testosterone was measured in house at 73% of laboratories. At the remaining laboratories studies were sent to larger centralized reference facilities. The mean ± SD lower reference value of total testosterone was 231 ± 46 ng/dl (range 160 to 300) and the mean upper limit was 850 ± 141 ng/dl (range 726 to 1,130). Only 9% of laboratories where in-house total testosterone testing was performed created a reference range unique to their region. Others validated the instrument recommended reference values in a small number of internal test samples. For free testosterone 82% of laboratories sent testing to larger centralized reference laboratories where equilibrium dialysis and/or liquid chromatography with mass spectrometry was done. The remaining laboratories used published algorithms to calculate serum free testosterone. Reference ranges for testosterone assays vary significantly among laboratories. The ranges are predominantly defined by limited population studies of men with unknown medical and reproductive histories. These poorly defined and variable reference values, especially the lower limit, affect how clinicians determine treatment. Copyright © 2016 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  7. Measurement Properties of Performance-Specific Pain Ratings of Patients Awaiting Total Joint Arthroplasty as a Consequence of Osteoarthritis

    Science.gov (United States)

    Stratford, Paul W.; Kennedy, Deborah M.; Woodhouse, Linda J.; Spadoni, Gregory

    2008-01-01

    Purpose: To estimate the test–retest reliability of the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) pain sub-scale and performance-specific assessments of pain, as well as the association between these measures for patients awaiting primary total hip or knee arthroplasty as a consequence of osteoarthritis. Methods: A total of 164 patients awaiting unilateral primary hip or knee arthroplasty completed four performance measures (self-paced walk, timed up and go, stair test, six-minute walk) and the WOMAC. Scores for 22 of these patients provided test–retest reliability data. Estimates of test–retest reliability (Type 2,1 intraclass correlation coefficient [ICC] and standard error of measurement [SEM]) and the association between measures were examined. Results: ICC values for individual performance-specific pain ratings were between 0.70 and 0.86; SEM values were between 0.97 and 1.33 pain points. ICC estimates for the four-item performance pain ratings and the WOMAC pain sub-scale were 0.82 and 0.57 respectively. The correlation between the sum of the pain scores for the four performance measures and the WOMAC pain sub-scale was 0.62. Conclusion: Reliability estimates for the performance-specific assessments of pain using the numeric pain rating scale were consistent with values reported for patients with a spectrum of musculoskeletal conditions. The reliability estimate for the WOMAC pain sub-scale was lower than typically reported in the literature. The level of association between the WOMAC pain sub-scale and the various performance-specific pain scales suggests that the scores can be used interchangeably when applied to groups but not for individual patients. PMID:20145758

  8. An initial SPARROW model of land use and in-stream controls on total organic carbon in streams of the conterminous United States

    Science.gov (United States)

    Shih, Jhih-Shyang; Alexander, Richard B.; Smith, Richard A.; Boyer, Elizabeth W.; Shwarz, Grogory E.; Chung, Susie

    2010-01-01

    Watersheds play many important roles in the carbon cycle: (1) they are a site for both terrestrial and aquatic carbon dioxide (CO2) removal through photosynthesis; (2) they transport living and decomposing organic carbon in streams and groundwater; and (3) they store organic carbon for widely varying lengths of time as a function of many biogeochemical factors. Using the U.S. Geological Survey (USGS) Spatially Referenced Regression on Watershed Attributes (SPARROW) model, along with long-term monitoring data on total organic carbon (TOC), this research quantitatively estimates the sources, transport, and fate of the long-term mean annual load of TOC in streams of the conterminous United States. The model simulations use surrogate measures of the major terrestrial and aquatic sources of organic carbon to estimate the long-term mean annual load of TOC in streams. The estimated carbon sources in the model are associated with four land uses (urban, cultivated, forest, and wetlands) and autochthonous fixation of carbon (stream photosynthesis). Stream photosynthesis is determined by reach-level application of an empirical model of stream chlorophyll based on total phosphorus concentration, and a mechanistic model of photosynthetic rate based on chlorophyll, average daily solar irradiance, water column light attenuation, and reach dimensions. It was found that the estimate of in-stream photosynthesis is a major contributor to the mean annual TOC load per unit of drainage area (that is, yield) in large streams, with a median share of about 60 percent of the total mean annual carbon load in streams with mean flows above 500 cubic feet per second. The interquartile range of the model predictions of TOC from in-stream photosynthesis is from 0.1 to 0.4 grams (g) carbon (C) per square meter (m-2) per day (day-1) for the approximately 62,000 stream reaches in the continental United States, which compares favorably with the reported literature range for net carbon fixation by

  9. Utilizing chromophoric dissolved organic matter measurements to derive export and reactivity of dissolved organic carbon exported to the Arctic Ocean: A case study of the Yukon River, Alaska

    Science.gov (United States)

    Spencer, R.G.M.; Aiken, G.R.; Butler, K.D.; Dornblaser, M.M.; Striegl, Robert G.; Hernes, P.J.

    2009-01-01

    The quality and quantity of dissolved organic matter (DOM) exported by Arctic rivers is known to vary with hydrology and this exported material plays a fundamental role in the biogeochemical cycling of carbon at high latitudes. We highlight the potential of optical measurements to examine DOM quality across the hydrograph in Arctic rivers. Furthermore, we establish chromophoric DOM (CDOM) relationships to dissolved organic carbon (DOC) and lignin phenols in the Yukon River and model DOC and lignin loads from CDOM measurements, the former in excellent agreement with long-term DOC monitoring data. Intensive sampling across the historically under-sampled spring flush period highlights the importance of this time for total export of DOC and particularly lignin. Calculated riverine DOC loads to the Arctic Ocean show an increase from previous estimates, especially when new higher discharge data are incorporated. Increased DOC loads indicate decreased residence times for terrigenous DOM in the Arctic Ocean with important implications for the reactivity and export of this material to the Atlantic Ocean. Citation: Spencer, R. G. M., G. R. Aiken, K. D. Butler, M. M. Dornblaser, R. G. Striegl, and P. J. Hernes (2009), Utilizing chromophoric dissolved organic matter measurements to derive export and reactivity of dissolved organic carbon exported to the Arctic Ocean: A case study of the Yukon River, Alaska, Geophys. Res. Lett., 36, L06401, doi:10.1029/ 2008GL036831. Copyright 2009 by the American Geophysical Union.

  10. Application of combined TLD and CR-39 PNTD method for measurement of total dose and dose equivalent on ISS

    International Nuclear Information System (INIS)

    Benton, E.R.; Deme, S.; Apathy, I.

    2006-01-01

    To date, no single passive detector has been found that measures dose equivalent from ionizing radiation exposure in low-Earth orbit. We have developed the I.S.S. Passive Dosimetry System (P.D.S.), utilizing a combination of TLD in the form of the self-contained Pille TLD system and stacks of CR-39 plastic nuclear track detector (P.N.T.D.) oriented in three mutually orthogonal directions, to measure total dose and dose equivalent aboard the International Space Station (I.S.S.). The Pille TLD system, consisting on an on board reader and a large number of Ca 2 SO 4 :Dy TLD cells, is used to measure absorbed dose. The Pille TLD cells are read out and annealed by the I.S.S. crew on orbit, such that dose information for any time period or condition, e.g. for E.V.A. or following a solar particle event, is immediately available. Near-tissue equivalent CR-39 P.N.T.D. provides Let spectrum, dose, and dose equivalent from charged particles of LET ∞ H 2 O ≥ 10 keV/μm, including the secondaries produced in interactions with high-energy neutrons. Dose information from CR-39 P.N.T.D. is used to correct the absorbed dose component ≥ 10 keV/μm measured in TLD to obtain total dose. Dose equivalent from CR-39 P.N.T.D. is combined with the dose component <10 keV/μm measured in TLD to obtain total dose equivalent. Dose rates ranging from 165 to 250 μGy/day and dose equivalent rates ranging from 340 to 450 μSv/day were measured aboard I.S.S. during the Expedition 2 mission in 2001. Results from the P.D.S. are consistent with those from other passive detectors tested as part of the ground-based I.C.C.H.I.B.A.N. intercomparison of space radiation dosimeters. (authors)

  11. Modeling Soil Organic Carbon Turnover in Four Temperate Forests Based on Radiocarbon Measurements of Heterotrophic Respiration and Soil Organic Carbon

    Science.gov (United States)

    Ahrens, B.; Borken, W.; Muhr, J.; Schrumpf, M.; Savage, K. E.; Wutzler, T.; Trumbore, S.; Reichstein, M.

    2011-12-01

    Soils of temperate forests store significant amounts of soil organic matter and are considered to be net sinks of atmospheric CO2. Soil organic carbon (SOC) dynamics have been studied using the Δ14C signature of bulk SOC or different SOC fractions as observational constraints in SOC models. Further, the Δ14C signature of CO2 evolved during the incubation of soil and roots has been widely used together with Δ14C of total soil respiration to partition soil respiration into heterotrophic respiration (Rh) and root respiration. However, these data have rarely been used together as observational constraints to determine SOC turnover times. Here, we present a multiple constraints approach, where we used SOC stock and its Δ14C signature, and heterotrophic respiration and its Δ14C signature to estimate SOC turnover times of a simple serial two-pool model via Bayesian optimization. We used data from four temperate forest ecosystems in Germany and the USA with different disturbance and management histories from selective logging to afforestation in the late 19th and early 20th century. The Δ14C signature of the atmosphere with its prominent bomb peak was used as a proxy for the Δ14C signature of aboveground and belowground litterfall. The Δ14C signature of litterfall was lagged behind the atmospheric signal to account for the period between photosynthetic fixation of carbon and its addition to SOC pools. We showed that the combined use of Δ14C measurements of Rh and SOC stocks helped to better constrain turnover times of the fast pool (primarily by Δ14C of Rh) and the slow pool (primarily by Δ14C of SOC). In particular, by introducing two additional parameters that describe the deviation from steady state of the fast and slow cycling pool for both SOC and SO14C, we were able to demonstrate that we cannot maintain the often used steady-state assumption of SOC models in general. Furthermore, a new transport version of our model, including SOC transport via

  12. Online Dialogue Measurement Index – A Measurement of the Dialogic Orientation of Organizations in the Online Environment

    DEFF Research Database (Denmark)

    Romenti, Stefania; Valentini, Chiara; Murtarelli, Grazia

    Dialogue has been recognized as an important component of organization-stakeholder relations and a communicative sign of openness and responsibility towards others. Still, developing dialogic communications with stakeholders is not an easy task and can also result to be counterproductive when...... dialogic communications create conflicts or bad reputations. Organizations require public relations professionals to measure the results of their communication activities including their dialogic efforts. Yet, dialogic communication measurements are scarce and often incomplete. The purpose of this study...

  13. Approach for determining the contributions of phytoplankton, colored organic material, and nonalgal particles to the total spectral absorption in marine waters.

    Science.gov (United States)

    Lin, Junfang; Cao, Wenxi; Wang, Guifeng; Hu, Shuibo

    2013-06-20

    Using a data set of 1333 samples, we assess the spectral absorption relationships of different wave bands for phytoplankton (ph) and particles. We find that a nonlinear model (second-order quadratic equations) delivers good performance in describing their spectral characteristics. Based on these spectral relationships, we develop a method for partitioning the total absorption coefficient into the contributions attributable to phytoplankton [a(ph)(λ)], colored dissolved organic material [CDOM; a(CDOM)(λ)], and nonalgal particles [NAP; a(NAP)(λ)]. This method is validated using a data set that contains 550 simultaneous measurements of phytoplankton, CDOM, and NAP from the NASA bio-Optical Marine Algorithm Dataset. We find that our method is highly efficient and robust, with significant accuracy: the relative root-mean-square errors (RMSEs) are 25.96%, 38.30%, and 19.96% for a(ph)(443), a(CDOM)(443), and the CDOM exponential slope, respectively. The performance is still satisfactory when the method is applied to water samples from the northern South China Sea as a regional case. The computed and measured absorption coefficients (167 samples) agree well with the RMSEs, i.e., 18.50%, 32.82%, and 10.21% for a(ph)(443), a(CDOM)(443), and the CDOM exponential slope, respectively. Finally, the partitioning method is applied directly to an independent data set (1160 samples) derived from the Bermuda Bio-Optics Project that contains relatively low absorption values, and we also obtain good inversion accuracy [RMSEs of 32.37%, 32.57%, and 11.52% for a(ph)(443), a(CDOM)(443), and the CDOM exponential slope, respectively]. Our results indicate that this partitioning method delivers satisfactory performance for the retrieval of a(ph), a(CDOM), and a(NAP). Therefore, this may be a useful tool for extracting absorption coefficients from in situ measurements or remotely sensed ocean-color data.

  14. Measurement of the total photon-photon cross section for the production of hadrons at small Q2

    International Nuclear Information System (INIS)

    Berger, C.; Deuter, A.; Genzel, H.; Lackas, W.; Pielorz, J.; Raupach, F.; Wagner, W.; Bussey, P.J.; Cartwright, S.L.; Dainton, J.B.; King, B.T.; Raine, C.; Scarr, J.M.; Skillicorn, I.O.; Smith, K.M.; Thomson, J.C.; Achterberg, O.; Blobel, V.; Burkart, D.; Diehlmann, K.; Feindt, M.; Kapitza, H.; Koppitz, B.; Krueger, M.; Poppe, M.; Spitzer, H.; Staa, R. van; Almeida, F.; Baecker, A.; Barreiro, F.; Brandt, S.; Derikum, K.; Grupen, C.; Meyer, H.J.; Mueller, H.; Neumann, B.; Rost, M.; Stupperich, K.; Zech, G.; Alexander, G.; Bella, G.; Gnat, Y.; Grunhaus, J.; Junge, H.; Kraski, K.; Maxeiner, C.; Maxeiner, H.; Meyer, H.; Schmidt, D.; Buerger, J.; Criegee, L.; Ferrarotto, F.; Franke, G.; Gaspero, M.; Gerke, C.; Knies, G.; Lewendel, B.; Meyer, J.; Michelsen, U.; Pape, K.H.; Stella, B.; Timm, U.; Winter, G.G.; Zachara, M.; Zimmermann, W.

    1984-09-01

    The total photon-photon cross section for the production of hadrons, sigmasub(γγ)(W,Q 2 ), has been measured in the single tag condition for 0.1 2 2 and 1.5 2 dependence of sigmasub(γγ) averaged over W can be described by GVDM. The dependence of sigmasub(γγ) on the mass W of the hadronic final state has been extracted at Q 2 =0.44 GeV 2 by unfolding the effects of experimental resolution and acceptance. The cross section is found to rise at small W. The result is compared with VDM and the parton model. (orig.)

  15. Measurement of the antiproton-proton total cross section at √s =546 and 1800 GeV

    International Nuclear Information System (INIS)

    Abe, F.; Albrow, M.; Amidei, D.; Anway-Wiese, C.; Apollinari, G.; Atac, M.; Auchincloss, P.; Azzi, P.; Bacchetta, N.; Baden, A.R.; Badgett, W.; Bailey, M.W.; Bamberger, A.; de Barbaro, P.; Barbaro-Galtieri, A.; Barnes, V.E.; Barnett, B.A.; Bauer, G.; Baumann, T.; Bedeschi, F.; Behrends, S.; Belforte, S.; Bellettini, G.; Bellinger, J.; Benjamin, D.; Benlloch, J.; Bensinger, J.; Beretvas, A.; Berge, J.P.; Bertolucci, S.; Biery, K.; Bhadra, S.; Binkley, M.; Bisello, D.; Blair, R.; Blocker, C.; Bodek, A.; Bolognesi, V.; Booth, A.W.; Boswell, C.; Brandenburg, G.; Brown, D.; Buckley-Geer, E.; Budd, H.S.; Busetto, G.; Byon-Wagner, A.; Byrum, K.L.; Campagnari, C.; Campbell, M.; Caner, A.; Carey, R.; Carithers, W.; Carlsmith, D.; Carroll, J.T.; Cashmore, R.; Castro, A.; Cen, Y.; Cervelli, F.; Chadwick, K.; Chapman, J.; Chapin, T.J.; Chiarelli, G.; Chinowsky, W.; Cihangir, S.; Clark, A.G.; Cobal, M.; Connor, D.; Contreras, M.; Cooper, J.; Cordelli, M.; Crane, D.; Cunningham, J.D.; Day, C.; DeJongh, F.; Dell'Agnello, S.; Dell'Orso, M.; Demortier, L.; Denby, B.; Derwent, P.F.; Devlin, T.; Dickson, M.; Drucker, R.B.; Dunn, A.; Einsweiler, K.; Elias, J.E.; Ely, R.; Eno, S.; Errede, S.; Etchegoyen, A.; Farhat, B.; Frautschi, M.; Feldman, G.J.; Flaugher, B.; Foster, G.W.; Franklin, M.; Freeman, J.; Fuess, T.; Fukui, Y.; Garfinkel, A.F.; Gauthier, A.; Geer, S.; Gerdes, D.W.; Giannetti, P.; Giokaris, N.; Giromini, P.; Gladney, L.; Gold, M.; Gonzalez, J.; Goulianos, K.; Grassmann, H.; Grieco, G.M.; Grindley, R.; Grosso-Pilcher, C.; Grunhaus, J.; Haber, C.; Hahn, S.R.; Handler, R.; Hara, K.; Harral, B.; Harris, R.M.; Hauger, S.A.; Hauser, J.; Hawk, C.; Hessing, T.; Hollebeek, R.; Holloway, L.; Hoelscher, A.; Hong, S.; Houk, G.; Hu, P.; Hubbard, B.; Huffman, B.T.; Hughes, R.; Hurst, P.; Huth, J.; Hylen, J.; Incagli, M.; Ino, T.; Iso, H.; Jessop, C.P.; Johnson, R.P.; Joshi, U.; Kadel, R.W.; Kamon, T.; Kanda, S.; Kardelis, D.A.; Karliner, I.; Kearns, E.; Keeble, L.

    1994-01-01

    We report a measurement of the proton-antiproton total cross section σ T at c.m.s. energies √s =546 and 1800 GeV. Using the luminosity-independent method, we find σ T =61.26±0.93 mb at √s =546 GeV and 80.03±2.24 mb at √s =1800 GeV. In this energy range, the ratio σ el /σ T increases from 0.210±0.002 to 0.246±0.004

  16. High accuracy subwavelength distance measurements: A variable-angle standing-wave total-internal-reflection optical microscope

    International Nuclear Information System (INIS)

    Haynie, A.; Min, T.-J.; Luan, L.; Mu, W.; Ketterson, J. B.

    2009-01-01

    We describe an extension of the total-internal-reflection microscopy technique that permits direct in-plane distance measurements with high accuracy (<10 nm) over a wide range of separations. This high position accuracy arises from the creation of a standing evanescent wave and the ability to sweep the nodal positions (intensity minima of the standing wave) in a controlled manner via both the incident angle and the relative phase of the incoming laser beams. Some control over the vertical resolution is available through the ability to scan the incoming angle and with it the evanescent penetration depth.

  17. Performance Evaluation and Measurement of the Organization in Strategic Analysis and Control: Methodological Aspects

    OpenAIRE

    Živan Ristić; Neđo Balaban

    2006-01-01

    Information acquired by measuring and evaluation are a necessary condition for good decision-making in strategic management. This work deals with : (a) Methodological aspects of evaluation (kinds of evaluation, metaevaluation) and measurement (supposition of isomorphism in measurement, kinds and levels of measurement, errors in measurement and the basic characteristics of measurement) (b) Evaluation and measurement of potential and accomplishments of the organization in Kaplan-Norton perspect...

  18. Measurement of total and differential cross sections of neutrino and antineutrino coherent π± production on carbon

    Science.gov (United States)

    Mislivec, A.; Higuera, A.; Aliaga, L.; Bellantoni, L.; Bercellie, A.; Betancourt, M.; Bodek, A.; Bravar, A.; Budd, H.; Caceres v., G. F. R.; Cai, T.; Martinez Caicedo, D. A.; Carneiro, M. F.; Chavarria, E.; da Motta, H.; Dytman, S. A.; Díaz, G. A.; Felix, J.; Fields, L.; Fine, R.; Gago, A. M.; Galindo, R.; Gallagher, H.; Ghosh, A.; Gran, R.; Harris, D. A.; Hurtado, K.; Jena, D.; Kleykamp, J.; Kordosky, M.; Le, T.; Maher, E.; Manly, S.; Mann, W. A.; Marshall, C. M.; McFarland, K. S.; Messerly, B.; Miller, J.; Morfín, J. G.; Mousseau, J.; Naples, D.; Nelson, J. K.; Nguyen, C.; Norrick, A.; Nuruzzaman, Paolone, V.; Perdue, G. N.; Ramírez, M. A.; Ransome, R. D.; Ray, H.; Ren, L.; Rimal, D.; Rodrigues, P. A.; Ruterbories, D.; Schellman, H.; Solano Salinas, C. J.; Sultana, M.; Sánchez Falero, S.; Tagg, N.; Valencia, E.; Wospakrik, M.; Yaeggy, B.; Zavala, G.; MinerνA Collaboration

    2018-02-01

    Neutrino induced coherent charged pion production on nuclei, ν¯ μA →μ±π∓A , is a rare inelastic interaction in which the four-momentum squared transferred to the nucleus is nearly zero, leaving it intact. We identify such events in the scintillator of MINERvA by reconstructing |t | from the final state pion and muon momenta and by removing events with evidence of energetic nuclear recoil or production of other final state particles. We measure the total neutrino and antineutrino cross sections as a function of neutrino energy between 2 and 20 GeV and measure flux integrated differential cross sections as a function of Q2 , Eπ, and θπ . The Q2 dependence and equality of the neutrino and antineutrino cross sections at finite Q2 provide a confirmation of Adler's partial conservation of axial current hypothesis.

  19. New neutron capture and total cross section measurements on 88Sr and their impact on s-process nucleosynthesis

    International Nuclear Information System (INIS)

    Koehler, P.E.; Spencer, R.R.; Guber, K.H.

    1998-01-01

    The authors have made new and improved measurements of the neutron capture and total cross sections of 88 Sr at the Oak Ridge Electron Linear Accelerator (ORELA). Improvements over previous measurements include a wider incident neutron energy range, the use of metallic rather than carbonate samples, better background subtraction, reduced sensitivity to sample-dependent backgrounds, and better pulse-height weighting functions. Because of its small cross section, the 88 Sr(n,γ) reaction is an important bottleneck during the s-process nucleosynthesis. Hence, an accurate determination of this rate is needed to better constrain the neutron exposure in s-process models and to more fully exploit the recently discovered isotopic anomalies in certain meteorites. They describe the experimental procedures, compare the results to previous data, and discuss their astrophysical impact

  20. Measurement of the total hadronic cross section in e sup + e minus annihilation at radical s =29 GeV

    Energy Technology Data Exchange (ETDEWEB)

    von Zanthier, C.; de Boer, W.; Grindhammer, G.; Hylen, J.; Harral, B.; Hearty, C.; Labarga, L.; Matthews, J.; Schaad, M.; Abrams, G.; Adolphsen, C.E.; Akerlof, C.; Alexander, J.P.; Alvarez, M.; Baden, A.R.; Ballam, J.; Barish, B.C.; Barklow, T.; Barnett, B.A.; Bartelt, J.; Blockus, D.; Bonvicini, G.; Boyarski, A.; Boyer, J.; Brabson, B.; Breakstone, A.; Brom, J.M.; Bulos, F.; Burchat, P.R.; Burke, D.L.; Butler, F.; Calvino, F.; Cence, R.J.; Chapman, J.; Cords, D.; Coupal, D.P.; DeStaebler, H.C.; Dorfan, D.E.; Dorfan, J.M.; Drell, P.S.; Feldman, G.J.; Fernandez, E.; Field, R.C.; Ford, W.T.; Fordham, C.; Frey, R.; Fujino, D.; Gan, K.K.; Gidal, G.; Glanzman, T.; Goldhaber, G.; Green, A.; Grosse-Wiesmann, P.; Haggerty, J.; Hanson, G.; Harr, R.; Harris, F.A.; Hawkes, C.M.; Hayes, K.; Herrup, D.; Heusch, C.A.; Himel, T.; Hoenk, M.; Hutchinson, D.; Innes, W.R.; Jaffre, M.; Jaros, J.A.; Juricic, I.; Kadyk, J.A.; Karlen, D.; Kent, J.; Klein, S.R.; Koska, W.; Kozanecki, W.; Lankford, A.J.; Larse

    1991-01-01

    A precise measurement of the ratio {ital R} of the total cross section {ital e}{sup +}{ital e{minus}}{r arrow}hadrons to the pointlike cross section {ital e}{sup +}{ital e{minus}}{r arrow}{mu}{sup +}{mu}{sup {minus}} at a center-of-mass energy of 29.0 GeV is presented. The data were taken