WorldWideScience

Sample records for total length tl

  1. The nonlinear light output of NaI(Tl) detectors in the Modular Total Absorption Spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Rasco, B.C., E-mail: crasco@lsu.edu [Department of Physics and Astronomy, Louisiana State University, Baton Rouge, LA 70803 (United States); Fijałkowska, A.; Karny, M. [Faculty of Physics, University of Warsaw, Pasteura 5, PL-02093 Warszawa (Poland); Rykaczewski, K.P. [Physics Division, Oak Ridge National Laboratory, Oak Ridge, TN 37831 (United States); Wolińska-Cichocka, M. [Physics Division, Oak Ridge National Laboratory, Oak Ridge, TN 37831 (United States); Oak Ridge Associated Universities, Oak Ridge, TN 37831 (United States); Heavy Ion Laboratory, University of Warsaw, Warsaw PL-02-093 (Poland); Grzywacz, R.; Goetz, K.C. [Department of Physics and Astronomy, University of Tennessee, Knoxville, TN 37966 (United States)

    2015-07-11

    A new detector array, the Modular Total Absorption Spectrometer (MTAS), was commissioned at the Holifield Radioactive Ion Beam Facility (HRIBF) at Oak Ridge National Lab (ORNL). Total absorption gamma spectra measured with MTAS are expected to improve beta-feeding patterns and beta strength functions in fission products. MTAS is constructed out of hexagonal NaI(Tl) detectors with a unique central module surrounded by 18 identical crystals assembled in three rings. The total NaI(Tl) mass of MTAS is over 1000 kg. The response of the central and other 18 MTAS modules to γ-radiation was simulated using the GEANT4 toolkit modified to analyze the nonlinear light output of NaI(Tl). A detailed description of the GEANT4 modifications made is discussed. Simulated energy resolution of MTAS modules is found to agree well with the measurements for single γ transitions of 662 keV ({sup 137}Cs) with 8.2% full width half maximum (FWHM), 835 keV ({sup 54}Mn) with FWHM of 7.5% FWHM, and 1115 keV ({sup 65}Zn) with FWHM of 6.5%. Simulations of single and multiple γ-rays from {sup 60}Co are also discussed.

  2. Reducing Length of Stay in Total Joint Arthroplasty Care.

    Science.gov (United States)

    Walters, Megan; Chambers, Monique C; Sayeed, Zain; Anoushiravani, Afshin A; El-Othmani, Mouhanad M; Saleh, Khaled J

    2016-10-01

    As health care reforms continue to improve quality of care, significant emphasis will be placed on evaluation of orthopedic patient outcomes. Total joint arthroplasty (TJA) has a proven track record of enhancing patient quality of life and are easily replicable. The outcomes of these procedures serve as a measure of health care initiative success. Specifically, length of stay, will be targeted as a marker of quality of surgical care delivered to TJA patients. Within this review, we will discuss preoperative and postoperative methods by which orthopedic surgeons may enhance TJA outcomes and effectively reduce length of stay. Copyright © 2016 Elsevier Inc. All rights reserved.

  3. Calculation of total counting efficiency of a NaI(Tl) detector by hybrid Monte-Carlo method for point and disk sources

    Energy Technology Data Exchange (ETDEWEB)

    Yalcin, S. [Education Faculty, Kastamonu University, 37200 Kastamonu (Turkey)], E-mail: yalcin@gazi.edu.tr; Gurler, O.; Kaynak, G. [Department of Physics, Faculty of Arts and Sciences, Uludag University, Gorukle Campus, 16059 Bursa (Turkey); Gundogdu, O. [Department of Physics, School of Engineering and Physical Sciences, University of Surrey, Guildford GU2 7XH (United Kingdom)

    2007-10-15

    This paper presents results on the total gamma counting efficiency of a NaI(Tl) detector from point and disk sources. The directions of photons emitted from the source were determined by Monte-Carlo techniques and the photon path lengths in the detector were determined by analytic equations depending on photon directions. This is called the hybrid Monte-Carlo method where analytical expressions are incorporated into the Monte-Carlo simulations. A major advantage of this technique is the short computation time compared to other techniques on similar computational platforms. Another advantage is the flexibility for inputting detector-related parameters (such as source-detector distance, detector radius, source radius, detector linear attenuation coefficient) into the algorithm developed, thus making it an easy and flexible method to apply to other detector systems and configurations. The results of the total counting efficiency model put forward for point and disc sources were compared with the previous work reported in the literature.

  4. Calculation of total counting efficiency of a NaI(Tl) detector by hybrid Monte-Carlo method for point and disk sources

    International Nuclear Information System (INIS)

    Yalcin, S.; Gurler, O.; Kaynak, G.; Gundogdu, O.

    2007-01-01

    This paper presents results on the total gamma counting efficiency of a NaI(Tl) detector from point and disk sources. The directions of photons emitted from the source were determined by Monte-Carlo techniques and the photon path lengths in the detector were determined by analytic equations depending on photon directions. This is called the hybrid Monte-Carlo method where analytical expressions are incorporated into the Monte-Carlo simulations. A major advantage of this technique is the short computation time compared to other techniques on similar computational platforms. Another advantage is the flexibility for inputting detector-related parameters (such as source-detector distance, detector radius, source radius, detector linear attenuation coefficient) into the algorithm developed, thus making it an easy and flexible method to apply to other detector systems and configurations. The results of the total counting efficiency model put forward for point and disc sources were compared with the previous work reported in the literature

  5. Comparison of total experimental and theoretical absolute γ-ray detection efficiencies of a cylindrical NaI(Tl) crystal

    International Nuclear Information System (INIS)

    Uosif, M.A.; El-Taher, A.

    2005-01-01

    A new fit function has been developed to calculate theoretically the absolute gamma ray detection efficiencies (ηTh) of a cylindrical NaI(Tl) crystal, for calculating the absolute efficiency at any interesting gamma energy in the energy range between 10 and 1300 keV and distance between 0 and 8 cm. The total absolute gamma ray detection efficiencies have been calculated for five detectors, four are 2x2 and one is 3x 3 inches NaI(Tl) crystal at different distances. The absolute efficiency of the different detectors was calculated at the specific energy of the standard sources for each measuring distances. In this calculation, experimental (ηExp) and theoretical (ηTh) have been calculated. The uncertainties of efficiency calibration have been calculated also for quality control. Measurements were performed with calibrated point source. Gamma-ray energies under consideration were 0.356, 0.662, 1.17 and 1.33 MeV. The differences between (ηExp) and (ηTh) at these energies are 1.30E-06, 7.99E-05, 2.29E-04 and 2.42E-04 respectively. The results obtained on the basis of (ηExp) and (ηTh) seem to be in very good agreement

  6. The role of Tl-201 total body scintigraphy in follow up of thyroid carcinoma

    International Nuclear Information System (INIS)

    Hoefnagel, C.A.; Delprat, C.C.; Marcuse, H.R.

    1985-01-01

    To evaluate the reliability of the procedure T1-201 total body scintigraphy was performed in 294 patients (449 studies) after total thyroidectomy for thyroid carcinoma. Results were correlated with I-131-scintigraphy and tumor-marker levels (Tgb or Calcitonin/CEA). T1-201 total body scintigraphy was negative in 196 patients with no evidence of disease. T1-201-scintigraphy correctly detected tumor localizations in 24 of 30 patients with I-131-positive metastases. In 28 patients T2-201 total body scintigraphy revealed metastases which did not concentrate I-131. Histology/cytology confirmed thyroid carcinoma metastases in 16 patients and other pathology in 5 cases. 9 of 18 patients with medullary thyroid carcinoma (I-131-negative) had elevated Calcitonin/CEA-levels. The T1-201 scintigram was positive in 8 of these patients. Comparison of T1-201, I-131 and tumor markers showed that only combined use of these parameters provide complete reliability. The authors conclude that T1-201 total body scintigraphy is useful in follow up of thyroid carcinoma, especially when a discrepancy of the other parameters exists and particularly in medullary carcinoma. In long term follow up of patients who are unsuspected of disease after successful therapy for thyroid carcinoma one can rely on T1-201 total body scintigraphy in combination with tumor marker assays

  7. Total internal conversion coefficient of the 260. 9 keV (7/sup +/->3/sup -/) transition in sup(198m)Tl

    Energy Technology Data Exchange (ETDEWEB)

    Venkateswara Rao, N.; Suryanarayana, C.; Narayana, D.G.S.; Bhuloka Reddy, S.; Satynarayana, G.; Sastry, D.L.; Chintalapudi, S.N.

    1986-02-21

    The 1.87 hours 543.7 keV (7/sup +/) isomeric state in /sup 198/Tl is produced via /sup 197/Au(..cap alpha.., 3n)sup(198m)Tl (Esub(..cap alpha..) = 35 MeV) reaction. The total conversion coefficient of 260.9 keV (7/sup +/ -> 3/sup -/) is determined for the first time by the intensity balance method. The value of ..cap alpha..sub(T)(260.9 keV) is found to be 40.1 +- 8.6 which is in good agreement with the theoretical value of Hager and Seltzer for pure M4 transition. The gamma transition probability of the 260.9 keV (M4) is calculated using the present value of ..cap alpha..sub(T) and compared with the single-particle estimate.

  8. Effects of the Length of Stay on the Cost of Total Knee and Total Hip Arthroplasty from 2002 to 2013.

    Science.gov (United States)

    Molloy, Ilda B; Martin, Brook I; Moschetti, Wayne E; Jevsevar, David S

    2017-03-01

    Utilization of total knee and hip arthroplasty has greatly increased in the past decade in the United States; these are among the most expensive procedures in patients with Medicare. Advances in surgical techniques, anesthesia, and care pathways decrease hospital length of stay. We examined how trends in hospital cost were altered by decreases in length of stay. Procedure, demographic, and economic data were collected on 6.4 million admissions for total knee arthroplasty and 2.8 million admissions for total hip arthroplasty from 2002 to 2013 using the National (Nationwide) Inpatient Sample, a component of the Healthcare Cost and Utilization Project. Trends in mean hospital costs and their association with length of stay were estimated using inflation-adjusted, survey-weighted generalized linear regression models, controlling for patient demographic characteristics and comorbidity. From 2002 to 2013, the length of stay decreased from a mean time of 4.06 to 2.97 days for total knee arthroplasty and from 4.06 to 2.75 days for total hip arthroplasty. During the same time period, the mean hospital cost for total knee arthroplasty increased from $14,988 (95% confidence interval [CI], $14,927 to $15,049) in 2002 to $22,837 (95% CI, $22,765 to $22,910) in 2013 (an overall increase of $7,849 or 52.4%). The mean hospital cost for total hip arthroplasty increased from $15,792 (95% CI, $15,706 to $15,878) in 2002 to $23,650 (95% CI, $23,544 to $23,755) in 2013 (an increase of $7,858 or 49.8%). If length of stay were set at the 2002 mean, the growth in cost for total knee arthroplasty would have been 70.8% instead of 52.4% as observed, and the growth in cost for total hip arthroplasty would have been 67.4% instead of 49.8% as observed. Hospital costs for joint replacement increased from 2002 to 2013, but were attenuated by reducing inpatient length of stay. With demographic characteristics showing an upward trend in the utilization of joint arthroplasty, including a shift

  9. Do illness rating systems predict discharge location, length of stay, and cost after total hip arthroplasty?

    Directory of Open Access Journals (Sweden)

    Sarah E. Rudasill, BA

    2018-06-01

    Conclusions: These findings suggest that although ASA classifications predict discharge location and SOI scores predict length of stay and total costs, other factors beyond illness rating systems remain stronger predictors of discharge for THA patients.

  10. Total Path Length and Number of Terminal Nodes for Decision Trees

    KAUST Repository

    Hussain, Shahid

    2014-01-01

    This paper presents a new tool for study of relationships between total path length (average depth) and number of terminal nodes for decision trees. These relationships are important from the point of view of optimization of decision trees

  11. No change in total length of white matter fibers in Alzheimer's disease

    DEFF Research Database (Denmark)

    Jorgensen, A.M.; Marner, L.; Pakkenberg, B.

    2008-01-01

    White matter changes have been reported as part of Alzheimer dementia. To investigate this, the total subcortical myelinated nerve fiber length was estimated in postmortem brains from eight females (age 79-88 years) with severe Alzheimer's disease (AD) and compared with brains from 10 female...

  12. Using pharyngeal teeth and chewing pads to estimate juvenile Silver Carp total length in the La Grange Reach, Illinois River

    Science.gov (United States)

    Lampo, Eli G.; Knights, Brent C.; Vallazza, Jon; Anderson, Cory A.; Rechkemmer, Will T.; Solomon, Levi E.; Casper, Andrew F.; Pendleton, Richard M.; Lamer, James T.

    2017-01-01

    The Silver Carp Hypophthalmichthys molitrix is an invasive species in the Mississippi River basin; an understanding of their vulnerability to predation as juveniles may inform control by native predators and predator enhancement (e.g., stocking). Digestion of Silver Carp prey recovered from diets makes it difficult to determine the size‐classes that are most vulnerable to predation by native fishes. The objective of this study was to determine whether the sizes of the chewing pad (CP), pharyngeal teeth (PT), and pharyngeal arch (PA)—the Silver Carp structures most often found intact in predator diets—were predictive of the TL of prey Silver Carp. During 2014 and 2015, juvenile Silver Carp (n = 136; <180 mm) were collected using 60‐Hz pulsed‐DC electrofishing and mini‐fyke nets in the La Grange reach of the Illinois River. We extracted Silver Carp CPs (n = 136 fish) and PAs with PT intact (n = 129 fish) and measured CP length (CPL) and width (CPW), eight reproducible PT landmarks (PT1L–PT4L; PT1W–PT4W), and four reproducible PA landmarks (PA1–PA4) to the nearest 0.01 µm. Using simple linear regression, we found a strong predictive relationship between measurements of CP, PT, or PA and the TL of Silver Carp. The CPL (r2 = 0.94) and CPW (r2 = 0.94) had the strongest relationships with Silver Carp TL, followed by PA1 (r2 = 0.89) and PT1L (r2 = 0.87). These strong relationships suggest that all three structures could be used in diet analyses to accurately estimate Silver Carp TL and thus further our understanding of predator–prey dynamics for this high‐risk invasive species.

  13. Total Path Length and Number of Terminal Nodes for Decision Trees

    KAUST Repository

    Hussain, Shahid

    2014-09-13

    This paper presents a new tool for study of relationships between total path length (average depth) and number of terminal nodes for decision trees. These relationships are important from the point of view of optimization of decision trees. In this particular case of total path length and number of terminal nodes, the relationships between these two cost functions are closely related with space-time trade-off. In addition to algorithm to compute the relationships, the paper also presents results of experiments with datasets from UCI ML Repository1. These experiments show how two cost functions behave for a given decision table and the resulting plots show the Pareto frontier or Pareto set of optimal points. Furthermore, in some cases this Pareto frontier is a singleton showing the total optimality of decision trees for the given decision table.

  14. Limb shortening osteotomy in a patient with achondroplasia and leg length difference after total hip arthroplasty

    Directory of Open Access Journals (Sweden)

    Christian L. Galata

    2013-07-01

    Full Text Available Introduction: Achondroplasia is the most common reason for disproportionate short stature. Normally, orthopedic limb lengthening procedures must be discussed in the course of this genetic disorder and have been successful in numerous achondroplastic patients in the past. In some cases, the disease may lead to leg length differences with need for surgical correction. Case Report: We report a case of achondroplastic dysplastic coxarthrosis with symptomatic leg length difference after bilateral total hip arthroplasty in a 52-year-old female patient, in which a distal femoral shortening osteotomy was successfully performed. Conclusion: Femoral shortening osteotomy is very uncommon in patients with achondroplasia. We conclude, however, that in rare cases it can be indicated and provide the advantage of shorter operation time, less perioperative complications and faster recovery compared to leg lengthening procedures. Keywords: Achondroplasia, dysplastic coxarthrosis, limb shortening, distal femur osteotomy.

  15. Relationships between total length and otolith size of bluefish Pomatomus saltatrix (Linnaeus, 1766 in the Marmara Sea of Turkey

    Directory of Open Access Journals (Sweden)

    Habib Bal

    2018-01-01

    Full Text Available In the present study, bluefish, Pomatomus saltatrix, was monthly collected from commercial fishing boats operating in the Marmara Sea between January and December 2014. The relationship between total length and otolith size of 346 bluefish samples were examined. Total lengths of females, males and unidentified samples were ranged from between 13.2-37.0, 12.3-34.8 and 13.0-31.6 cm, respectively. Otolith lengths were between 3.82-12.60 mm and otolith width were between 1.59-4.34 mm for all samples. It was found that there is a strong correlations between otolith length-total length (r2 =0.88 and otolith width-total length (r2 0.81.

  16. A genome-wide association scan (GWAS) for mean telomere length within the COGS project

    DEFF Research Database (Denmark)

    Pooley, Karen A; Bojesen, Stig E; Weischer, Maren

    2013-01-01

    Mean telomere length (TL) in blood cells is heritable and has been reported to be associated with risks of several diseases, including cancer. We conducted a meta-analysis of three GWAS for TL (total n=2240) and selected 1629 variants for replication via the "iCOGS" custom genotyping array. All...

  17. Doped Tl-1212 and Tl-1223 superconductors

    International Nuclear Information System (INIS)

    Eder, M.H.

    2001-09-01

    This work describes the preparation and characterization of thallium-lead-strontium-barium-calcium-(uranium)-copperoxide (Tl-1212, Tl-1223) high-temperature superconductors. The precursors were prepared via nitrate method. After calcination the oxidic powders were mixed with stoichiometric amounts of an Tl 2 O 3 , PbO, Er 2 O 3 and Gd 2 O 3 by milling and afterwards uniaxial compressed. Sintering was carried out in silver foils. X-ray diffractometry and high-resolution microscopy in combination with scanning electron microscopy (including EDAX) were used to study the influence of varying thallium/lead-, strontium/barium-, calcium/rare earth element ratios and the effect of uranium on the phase composition and microstructure of bulk superconductors. Furthermore the influence of the composition on the electrical and magnetical properties was studied. On phase pure Tl-1212 and Tl-1223 superconductors NMR-measurements were done. Small amounts of gadolinium and erbium instead of calcium and excess-uranium have a positive impact on the electrical and magnetical properties of the Tl-1223 superconductors. Higher amounts of these doping elements favor the Tl-1212 phase. Tl-1212 superconductors with varying thallium/lead- strontium/barium- and calcium/gadolinium ratios were prepared phasepure in wide range of doping. Transition temperatures up to 96 K were achieved. It was shown that lead has an oxidation number of +4 and thallium of +3. (author)

  18. Proposed standard-weight (Ws) equation and length-categorization standards for brown trout (Salmo trutta) in lentic habitats

    Science.gov (United States)

    Hyatt, M.W.; Hubert, W.A.

    2001-01-01

    We developed a standard-weight (Ws) equation for brown trout (Salmo trutta) in lentic habitats by applying the regression-line-percentile technique to samples from 49 populations in North America. The proposed Ws equation is log10 Ws = -5.422 + 3.194 log10 TL, when Ws is in grams and TL is total length in millimeters. The English-unit equivalent is log10 Ws = -3.592 + 3.194 log10 TL, when Ws is in pounds and TL is total length in inches. The equation is applicable for fish of 140-750 mm TL. Proposed length-category standards to evaluate fish within populations are: stock, 200 mm (8 in); quality, 300 mm (12 in); preferred, 400 mm (16 in); memorable, 500 mm (20 in); and trophy, 600 mm (24 in).

  19. Do climate variables and human density affect Achatina fulica (Bowditch) (Gastropoda: Pulmonata) shell length, total weight and condition factor?

    Science.gov (United States)

    Albuquerque, F S; Peso-Aguiar, M C; Assunção-Albuquerque, M J T; Gálvez, L

    2009-08-01

    The length-weight relationship and condition factor have been broadly investigated in snails to obtain the index of physical condition of populations and evaluate habitat quality. Herein, our goal was to describe the best predictors that explain Achatina fulica biometrical parameters and well being in a recently introduced population. From November 2001 to November 2002, monthly snail samples were collected in Lauro de Freitas City, Bahia, Brazil. Shell length and total weight were measured in the laboratory and the potential curve and condition factor were calculated. Five environmental variables were considered: temperature range, mean temperature, humidity, precipitation and human density. Multiple regressions were used to generate models including multiple predictors, via model selection approach, and then ranked with AIC criteria. Partial regressions were used to obtain the separated coefficients of determination of climate and human density models. A total of 1.460 individuals were collected, presenting a shell length range between 4.8 to 102.5 mm (mean: 42.18 mm). The relationship between total length and total weight revealed that Achatina fulica presented a negative allometric growth. Simple regression indicated that humidity has a significant influence on A. fulica total length and weight. Temperature range was the main variable that influenced the condition factor. Multiple regressions showed that climatic and human variables explain a small proportion of the variance in shell length and total weight, but may explain up to 55.7% of the condition factor variance. Consequently, we believe that the well being and biometric parameters of A. fulica can be influenced by climatic and human density factors.

  20. Do climate variables and human density affect Achatina fulica (Bowditch (Gastropoda: Pulmonata shell length, total weight and condition factor?

    Directory of Open Access Journals (Sweden)

    FS. Albuquerque

    Full Text Available The length-weight relationship and condition factor have been broadly investigated in snails to obtain the index of physical condition of populations and evaluate habitat quality. Herein, our goal was to describe the best predictors that explain Achatina fulica biometrical parameters and well being in a recently introduced population. From November 2001 to November 2002, monthly snail samples were collected in Lauro de Freitas City, Bahia, Brazil. Shell length and total weight were measured in the laboratory and the potential curve and condition factor were calculated. Five environmental variables were considered: temperature range, mean temperature, humidity, precipitation and human density. Multiple regressions were used to generate models including multiple predictors, via model selection approach, and then ranked with AIC criteria. Partial regressions were used to obtain the separated coefficients of determination of climate and human density models. A total of 1.460 individuals were collected, presenting a shell length range between 4.8 to 102.5 mm (mean: 42.18 mm. The relationship between total length and total weight revealed that Achatina fulica presented a negative allometric growth. Simple regression indicated that humidity has a significant influence on A. fulica total length and weight. Temperature range was the main variable that influenced the condition factor. Multiple regressions showed that climatic and human variables explain a small proportion of the variance in shell length and total weight, but may explain up to 55.7% of the condition factor variance. Consequently, we believe that the well being and biometric parameters of A. fulica can be influenced by climatic and human density factors.

  1. On the total number of genes and their length distribution in complete microbial genomes

    DEFF Research Database (Denmark)

    Skovgaard, Marie; Jensen, L.J.; Brunak, Søren

    2001-01-01

    In sequenced microbial genomes, some of the annotated genes are actually not protein-coding genes, but rather open reading frames that occur by chance. Therefore, the number of annotated genes is higher than the actual number of genes for most of these microbes. Comparison of the length...... distribution of the annotated genes with the length distribution of those matching a known protein reveals that too many short genes are annotated in many genomes. Here we estimate the true number of protein-coding genes for sequenced genomes. Although it is often claimed that Escherichia coli has about 4300...... genes, we show that it probably has only similar to 3800 genes, and that a similar discrepancy exists for almost all published genomes....

  2. Telomere length differences between subcutaneous and visceral adipose tissue in humans

    International Nuclear Information System (INIS)

    Lakowa, Nicole; Trieu, Nhu; Flehmig, Gesine; Lohmann, Tobias; Schön, Michael R.; Dietrich, Arne; Zeplin, Philip Helge; Langer, Stefan; Stumvoll, Michael; Blüher, Matthias; Klöting, Nora

    2015-01-01

    Adipocyte hypertrophy and hyperplasia have been shown to be associated with shorter telomere length, which may reflect aging, altered cell proliferation and adipose tissue (AT) dysfunction. In individuals with obesity, differences in fat distribution and AT cellular composition may contribute to obesity related metabolic diseases. Here, we tested the hypotheses that telomere lengths (TL) are different between: (1) abdominal subcutaneous and omental fat depots, (2) superficial and deep abdominal subcutaneous AT (SAT), and (3) adipocytes and cells of the stromal vascular fraction (SVF). We further asked whether AT TL is related to age, anthropometric and metabolic traits. TL was analyzed by quantitative PCR in total human genomic DNA isolated from paired subcutaneous and visceral AT of 47 lean and 50 obese individuals. In subgroups, we analyzed TL in isolated small and large adipocytes and SVF cells. We find significantly shorter TL in subcutaneous compared to visceral AT (P < 0.001) which is consistent in men and subgroups of lean and obese, and individuals with or without type 2 diabetes (T2D). Shorter TL in SAT is entirely due to shorter TL in the SVF compared to visceral AT (P < 0.01). SAT TL is most strongly correlated with age (r = −0.205, P < 0.05) and independently of age with HbA1c (r = −0.5, P < 0.05). We found significant TL differences between superficial SAT of lean and obese as well as between individuals with our without T2D, but not between the two layers of SAT. Our data indicate that fat depot differences in TL mainly reflect shorter TL of SVF cells. In addition, we found an age and BMI-independent relationship between shorter TL and HbA1c suggesting that chronic hyperglycemia may impair the regenerative capacity of AT more strongly than obesity alone. - Highlights: • Telomere lengths (TL) differ between fat depots mainly due to different lengths in SVF. • TL is not associated with gender, BMI and T2D. • The tendency for

  3. Telomere length differences between subcutaneous and visceral adipose tissue in humans

    Energy Technology Data Exchange (ETDEWEB)

    Lakowa, Nicole; Trieu, Nhu; Flehmig, Gesine [Department of Medicine, University of Leipzig, Leipzig (Germany); Lohmann, Tobias [Municipal Clinic Dresden-Neustadt, Dresden (Germany); Schön, Michael R. [Städtisches Klinikum Karlsruhe, Clinic of Visceral Surgery, Karlsruhe (Germany); Dietrich, Arne [Department of Surgery, University of Leipzig, Leipzig (Germany); IFB AdiposityDiseases, University of Leipzig, Leipzig (Germany); Zeplin, Philip Helge; Langer, Stefan [Department of Orthopaedics, Traumatology and Plastic Surgery, University of Leipzig, Leipzig (Germany); Stumvoll, Michael; Blüher, Matthias [Department of Medicine, University of Leipzig, Leipzig (Germany); Klöting, Nora, E-mail: nora.kloeting@medizin.uni-leipzig.de [IFB AdiposityDiseases, Junior Research Group 2 “Animal Models of Obesity”, University of Leipzig, Leipzig (Germany)

    2015-02-13

    Adipocyte hypertrophy and hyperplasia have been shown to be associated with shorter telomere length, which may reflect aging, altered cell proliferation and adipose tissue (AT) dysfunction. In individuals with obesity, differences in fat distribution and AT cellular composition may contribute to obesity related metabolic diseases. Here, we tested the hypotheses that telomere lengths (TL) are different between: (1) abdominal subcutaneous and omental fat depots, (2) superficial and deep abdominal subcutaneous AT (SAT), and (3) adipocytes and cells of the stromal vascular fraction (SVF). We further asked whether AT TL is related to age, anthropometric and metabolic traits. TL was analyzed by quantitative PCR in total human genomic DNA isolated from paired subcutaneous and visceral AT of 47 lean and 50 obese individuals. In subgroups, we analyzed TL in isolated small and large adipocytes and SVF cells. We find significantly shorter TL in subcutaneous compared to visceral AT (P < 0.001) which is consistent in men and subgroups of lean and obese, and individuals with or without type 2 diabetes (T2D). Shorter TL in SAT is entirely due to shorter TL in the SVF compared to visceral AT (P < 0.01). SAT TL is most strongly correlated with age (r = −0.205, P < 0.05) and independently of age with HbA1c (r = −0.5, P < 0.05). We found significant TL differences between superficial SAT of lean and obese as well as between individuals with our without T2D, but not between the two layers of SAT. Our data indicate that fat depot differences in TL mainly reflect shorter TL of SVF cells. In addition, we found an age and BMI-independent relationship between shorter TL and HbA1c suggesting that chronic hyperglycemia may impair the regenerative capacity of AT more strongly than obesity alone. - Highlights: • Telomere lengths (TL) differ between fat depots mainly due to different lengths in SVF. • TL is not associated with gender, BMI and T2D. • The tendency for

  4. On the total number of genes and their length distribution in complete microbial genomes

    DEFF Research Database (Denmark)

    Skovgaard, M; Jensen, L J; Brunak, S

    2001-01-01

    In sequenced microbial genomes, some of the annotated genes are actually not protein-coding genes, but rather open reading frames that occur by chance. Therefore, the number of annotated genes is higher than the actual number of genes for most of these microbes. Comparison of the length distribut......In sequenced microbial genomes, some of the annotated genes are actually not protein-coding genes, but rather open reading frames that occur by chance. Therefore, the number of annotated genes is higher than the actual number of genes for most of these microbes. Comparison of the length...... distribution of the annotated genes with the length distribution of those matching a known protein reveals that too many short genes are annotated in many genomes. Here we estimate the true number of protein-coding genes for sequenced genomes. Although it is often claimed that Escherichia coli has about 4300...... genes, we show that it probably has only approximately 3800 genes, and that a similar discrepancy exists for almost all published genomes....

  5. Association of nursing-documented ambulation with length of stay following total laparoscopic hysterectomy for benign gynecologic disease

    OpenAIRE

    Kim, Kidong; Yoo, Sooyoung; Yang, Eun Joo; No, Jae Hong; Hwang, Hee; Kim, Yong-Beom

    2013-01-01

    Objective The objective was to examine the association of postoperative physical activity with length of stay in patients who received total laparoscopic hysterectomy for benign gynecologic disease. Methods The case group was composed of 70 patients who entered a critical pathway for elective total laparoscopic hysterectomy from 2009 to 2012 and were discharged behind schedule. The control group was selected from patients who were discharged on schedule, and matched to cases using 1:3 ratio p...

  6. Reducing the length of hospital stay after total knee arthroplasty: influence of femoral and sciatic nerve block.

    Science.gov (United States)

    Carvalho Júnior, Lúcio Honório de; Temponi, Eduardo Frois; Paganini, Vinícius Oliveira; Costa, Lincoln Paiva; Soares, Luiz Fernando Machado; Gonçalves, Matheus Braga Jacques

    2015-01-01

    the aim of this study is to evaluate the change in length of hospital stay postoperatively for Total Knee Arthroplasty after using femoral and sciatic nerve block. the medical records of 287 patients were evaluated, taking into account the number of hours of admission, the percentage and the reason for re-hospitalization within 30 days, as well as associated complications. All patients were divided into two groups according or not to whether they were admitted to ICU or not. During the years 2009 and 2010, isolated spinal anesthesia was the method used in the procedure. From 2011 on, femoral and sciatic nerve blocking was introduced. between the years 2009 and 2012, the average length of stay ranged from 74 hours in 2009 to 75.2 hours in 2010. The average length of stay in 2011 was 56.52 hours and 53.72 hours in 2012, all in the group of patients who did not remain in the ICU postoperatively. In the same period, among those in the group that needed ICU admission, the average length of stay was 138.7 hours in 2009, 90.25 hours in 2010, 79.8 hours in 2011, and 52.91 hours in 2012. During 2009 and 2010, the rate of re-hospitalization was 0%, while in 2011 and 2012, were 3.44% and 1%, respectively. according to this study, the use of femoral and sciatic nerve blocking after total knee arthroplasty allowed significant reduction in hospital stay.

  7. TL transgenic mouse strains

    International Nuclear Information System (INIS)

    Obata, Y.; Matsudaira, Y.; Hasegawa, H.; Tamaki, H.; Takahashi, T.; Morita, A.; Kasai, K.

    1993-01-01

    As a result of abnormal development of the thymus of these mice, TCR αβ lineage of the T cell differentiation is disturbed and cells belonging to the TCR γδ CD4 - CD8 - double negative (DN) lineage become preponderant. The γδ DN cells migrate into peripheral lymphoid organs and constitute nearly 50% of peripheral T cells. Immune function of the transgenic mice is severely impaired, indicating that the γδ cells are incapable of participating in these reactions. Molecular and serological analyses of T-cell lymphomas reveal that they belong to the γδ lineage. Tg.Tla a -3-1 mice should be useful in defining the role of TL in normal and abnormal T cell differentiation as well as in the development of T-cell lymphomas, and further they should facilitate studies on the differentiation and function of γδ T cells. We isolated T3 b -TL gene from B6 mice and constructed a chimeric gene in which T3 b -TL is driven by the promoter of H-2K b . With the chimeric gene, two transgenic mouse strains, Tg. Con.3-1 and -2 have been derived in C3H background. Both strains express TL antigen in various tissues including skin. The skin graft of transgenic mice on C3H and (B6 X C3H)F 1 mice were rejected. In the mice which rejected the grafts, CD8 + TCRαβ cytotoxic T cells (CTL) against TL antigens were recognized. The recognition of TL by CTL did not require the antigen presentation by H-2 molecules. The results indicated that TL antigen in the skin becomes a transplantation antigen and behaves like a typical allogeneic MHC class I antigen. The facts that (B6 X C3H)F 1 mice rejected the skin expressing T3 b -TL antigen and induced CTL that killed TL + lymphomas of B6 origin revealed that TL antigen encoded by T3 b -TL is recognized as non-self in B6 mice. Experiments are now extended to analyze immune responses to TL antigen expressed on autochthonous T cell lymphomas. (J.P.N.)

  8. Relationship between the total length of the stents and patients' quality of life after percutaneous coronary intervention.

    Science.gov (United States)

    Liu, Wei; Yang, Xuming; Dong, Pingshuan; Li, Zhijuan

    2015-01-01

    The aim of this study was to examine the relationship between the total length of the stents and the postoperative life quality of patients with multi-vessel coronary artery disease who undergo percutaneous coronary intervention (PCI). Using the short-form health survey (SF-36) items, we analyzed the data on the postoperative life quality of 166 patients with multi-vessel coronary artery disease who underwent percutaneous transluminal coronary intervention in the Department of Cardiology of the First Affiliated Hospital of Henan University of Science and Technology from September 2011 to September 2013. Follow-up was performed 6 months later. All of the dimensionalities, except general health and mental health, showed significantly higher scores after PCI. No significant relationships were observed between the total length of the stents and the postoperative life quality of patients with multi-vessel coronary artery disease who underwent PCI. PCI can effectively improve the postoperative life quality of patients; however, there was no significant relationship between the total length of the stents and postoperative life quality of patients.

  9. A genome-wide association scan (GWAS) for mean telomere length within the COGS project: identified loci show little association with hormone-related cancer risk

    OpenAIRE

    Pooley, K. A.; Bojesen, S. E.; Weischer, M.; Nielsen, S. F.; Thompson, D.; Amin Al Olama, A.; Michailidou, K.; Tyrer, J. P.; Benlloch, S.; Brown, J.; Audley, T.; Luben, R.; Khaw, K.-T.; Neal, D. E.; Hamdy, F. C.

    2013-01-01

    Mean telomere length (TL) in blood cells is heritable and has been reported to be associated with risks of several diseases, including cancer. We conducted a meta-analysis of three GWAS for TL (total n=2240) and selected 1629 variants for replication via the ?iCOGS? custom genotyping array. All ?200 000 iCOGS variants were analysed with TL, and those displaying associations in healthy controls (n = 15 065) were further tested in breast cancer cases (n = 11 024). We found a novel TL associatio...

  10. Reducing the length of hospital stay after total knee arthroplasty: influence of femoral and sciatic nerve block

    Directory of Open Access Journals (Sweden)

    Lúcio Honório de Carvalho Júnior

    2015-02-01

    Full Text Available Objective: the aim of this study is to evaluate the change in length of hospital stay postoperatively for Total Knee Arthroplasty after using femoral and sciatic nerve block. Materials and methods: the medical records of 287 patients were evaluated, taking into account the number of hours of admission, the percentage and the reason for re-hospitalization within 30 days, as well as associated complications. All patients were divided into two groups according or not to whether they were admitted to ICU or not. During the years 2009 and 2010, isolated spinal anesthesia was the method used in the procedure. From 2011 on, femoral and sciatic nerve blocking was introduced. Results: between the years 2009 and 2012, the average length of stay ranged from 74 hours in 2009 to 75.2 hours in 2010. The average length of stay in 2011 was 56.52 hours and 53.72 hours in 2012, all in the group of patients who did not remain in the ICU postoperatively. In the same period, among those in the group that needed ICU admission, the average length of stay was 138.7 hours in 2009, 90.25 hours in 2010, 79.8 hours in 2011, and 52.91 hours in 2012. During 2009 and 2010, the rate of re-hospitalization was 0%, while in 2011 and 2012, were 3.44% and 1%, respectively. Conclusion: according to this study, the use of femoral and sciatic nerve blocking after total knee arthroplasty allowed significant reduction in hospital stay.

  11. An unbiased stereological method for efficiently quantifying the innervation of the heart and other organs based on total length estimations

    DEFF Research Database (Denmark)

    Mühlfeld, Christian; Papadakis, Tamara; Krasteva, Gabriela

    2010-01-01

    Quantitative information about the innervation is essential to analyze the structure-function relationships of organs. So far, there has been no unbiased stereological tool for this purpose. This study presents a new unbiased and efficient method to quantify the total length of axons in a given...... reference volume, illustrated on the left ventricle of the mouse heart. The method is based on the following steps: 1) estimation of the reference volume; 2) randomization of location and orientation using appropriate sampling techniques; 3) counting of nerve fiber profiles hit by a defined test area within...

  12. Study of optical non-linear properties of a constant total effective length multiple quantum wells system

    International Nuclear Information System (INIS)

    Solaimani, M.; Morteza, Izadifard; Arabshahi, H.; Reza, Sarkardehi Mohammad

    2013-01-01

    In this work, we have studied the effect of the number of the wells, in a multiple quantum wells structure with constant total effective length, on the optical properties of multiple quantum wells like the absorption coefficient and the refractive index by means of compact density matrix approach. GaAs/Al x Ga (1−x) As multiple quantum wells systems was selected as an example. Besides, the effect of varying number of wells on the subband energies, wave functions, number of bound states, and the Fermi energy have been also investigated. Our calculation revealed that the number of wells in a multiple quantum well is a criterion with which we can control the amount of nonlinearity. This study showed that for the third order refractive index change there is two regimes of variations and the critical well number was six. In our calculations, we have used the same wells and barrier thicknesses to construct the multiple quantum wells system. - Highlights: ► OptiOptical Non-Linear. ► Total Effective Length. ► Multiple Quantum Wells System - genetic algorithm ► Schrödinger equation solution. ► Nanostructure.

  13. Relationships of body lengths with mouth opening and prey length of nemipterid fishes (Regan, 1913 in the Gulf of Thailand

    Directory of Open Access Journals (Sweden)

    Mithun Paul

    2017-12-01

    Full Text Available This study aims to investigate the relationship among total length (TL of fish with mouth opening namely horizontal opening (MH, vertical opening (VH, mouth area (MA and fork length (FL of seven sympatric nemipterid fish species and to know the relationship between total length and consumed prey length of five sympatric species sampled from the Gulf of Thailand in 2015. A total 883 fish were investigated collected from both cruise surveys and fishing port survey. TL was linearly and log-linearly related with both MV and MH for three and four species, respectively. MA’s were always the log linear relation of TL and shapes were nearly oval for all species. FL in all TL-FL relationships were proportional to the TL’s in all species (r2 = 0.94, P  .5 and in invertebrate prey items for N. tambuloides (P > .5. So, this study clearly confirms that nemipterid fishes of different sizes feed on all different specific prey items according to its own body size and feed according to size class for prey items available nearby.

  14. Total direct cost, length of hospital stay, institutional discharges and their determinants from rehabilitation settings in stroke patients.

    Science.gov (United States)

    Saxena, S K; Ng, T P; Yong, D; Fong, N P; Gerald, K

    2006-11-01

    Length of hospital stay (LOHS) is the largest determinant of direct cost for stroke care. Institutional discharges (acute care and nursing homes) from rehabilitation settings add to the direct cost. It is important to identify potentially preventable medical and non-medical reasons determining LOHS and institutional discharges to reduce the direct cost of stroke care. The aim of the study was to ascertain the total direct cost, LOHS, frequency of institutional discharges and their determinants from rehabilitation settings. Observational study was conducted on 200 stroke patients in two rehabilitation settings. The patients were examined for various socio-demographic, neurological and clinical variables upon admission to the rehabilitation hospitals. Information on total direct cost and medical complications during hospitalization were also recorded. The outcome variables measured were total direct cost, LOHS and discharges to institutions (acute care and nursing home facility) and their determinants. The mean and median LOHS in our study were 34 days (SD = 18) and 32 days respectively. LOHS and the cost of hospital stay were significantly correlated. The significant variables associated with LOHS on multiple linear regression analysis were: (i) severe functional impairment/functional dependence Barthel Index institutional discharges (22 to acute care and 17 to nursing homes). On multivariate analysis the significant predictors of discharges to institutions from rehabilitation hospitals were medical complications (OR = 4.37; 95% CI 1.01-12.53) and severe functional impairment/functional dependence. (OR = 5.90, 95% CI 2.32-14.98). Length of hospital stay and discharges to institutions from rehabilitation settings are significantly determined by medical complications. Importance of adhering to clinical pathway/protocol for stroke care is further discussed.

  15. Validation and dosimetric evaluation employing the techniques of TL and OSL of thermoluminescent materials for application in the dosimetry of clinical beams of electrons used in total irradiation of the skin - TSI

    International Nuclear Information System (INIS)

    Almeida, Shirlane Barbosa de

    2017-01-01

    In vivo dosimetry has become an important role for the treatment of total skin irradiation within a rigorous quality assurance program that should be an integral part of the radiotherapy departments. TSI dosimetry is difficult because of the complexity of the treatment in assessing dose uniformity and measuring the dose absorbed at shallow depths throughout the skin surface extent, resulting in a wide variation in dose distribution. The TLDs have proven to be very useful for the distribution and verification of the dose prescribed for the patient as the dose may differ from place to place due to patient body geometry, overlapping of structures and asymmetries of the radiation field. The use of TLDs in vivo can identify variations in the prescribed dose because its measurement accuracy and great precision. Several types of dosimeters have been used in the radiotherapy sectors, the most commonly used are Lithium Fluride (TLD-100), where it obtains a long history in this type of application. New dosimetric materials have gained great importance in the dosimetry of clinical electron beams, such as Dysprosium-doped Calcium Sulphate (TL) and Carbon doped (OSL) based Aluminum Oxide, This work evaluates the performance of the respective thermoluminescent dosimeters and the optically stimulated luminescence in the dosimetry of clinical electron beams used in total irradiation of the skin. (author)

  16. The neutron diffraction of molten TlCl, TlBr, and TlI

    International Nuclear Information System (INIS)

    Satow, T.; Uemura, O.; Hoshino, K.; Watanabe, T.

    1984-01-01

    Structure factors S(K) for liquid TlCl, TlBr, and TlI are determined by neutron diffraction measurements. Atomic radial distribution functions (RDF) derived from S(K) are presented. All RDF values are slightly smaller than those of their solid state counter parts. Results show that TlX has a tendency not to retain cesium-chloride type local order, but to take sodium-chloride type order when melting

  17. 205Tl experiment

    International Nuclear Information System (INIS)

    Henning, W.; Kutschera, W.; Ernst, H.

    1984-01-01

    205 Tl has been previously proposed as a geological detector for solar neutrinos, making use of the reaction 205 Tl(nu, e - ) 205 Pb with a neutrino threshold of only approx. = 43 keV. We report on an experiment performed to study the feasibility of detecting radioactive 205 Pb nuclei (T/sub 1/2/ = 15 million years) at very low concentrations using the recently developed technique of accelerator mass spectrometry. Employing the high-energy ion beams of good quality from the UNILAC heavy-ion accelerator at the GSI Darmstadt, we are able to demonstrate a suppression of neighbouring isotopes to better than 1 in 10 16 and of neighbouring elements to about 1 in 10 3 . While these results are very encouraging, the minimum number of atoms detectable is still severely limited by the efficiency of producing multiply-charged ions from present ion sources. Future improvements in ion-source performance are briefly discussed

  18. Dielectric and baric characteristics of TlS single crystal

    Energy Technology Data Exchange (ETDEWEB)

    Mustafaeva, S.N., E-mail: solmust@gmail.com [Institute of Physics, ANAS, G. Javid prosp. 33, Az 1143 Baku (Azerbaijan); Asadov, M.M. [Institute of Chemical Problems, ANAS, G. Javid prosp. 29, Az 1143 Baku (Azerbaijan); Ismailov, A.A. [Institute of Physics, ANAS, G. Javid prosp. 33, Az 1143 Baku (Azerbaijan)

    2014-11-15

    The investigation of the frequency dependences of the dielectric coefficients and ac-conductivity of the TlS single crystals made it possible to elucidate the nature of dielectric loss and the charge transfer mechanism. Moreover, we evaluated the density and energy spread of localized states near the Fermi level, the average hopping time and the average hopping length. It was shown that the dc-conductivity of the TlS single crystals can be controlled by varying the hydrostatic pressure. This has opened up possibilities for using TlS single crystals as active elements of pressure detectors.

  19. Dyslipidemia and chronic inflammation markers are correlated with telomere length shortening in Cushing's syndrome.

    Directory of Open Access Journals (Sweden)

    Anna Aulinas

    Full Text Available Cushing's syndrome (CS increases cardiovascular risk (CVR and adipocytokine imbalance, associated with an increased inflammatory state. Telomere length (TL shortening is a novel CVR marker, associated with inflammation biomarkers. We hypothesized that inflammatory state and higher CVR in CS might be related to TL shortening, as observed in premature aging.To evaluate relationships between TL, CVR and inflammation markers in CS.In a cross-sectional study, 77 patients with CS (14 males, 59 pituitary-, 17 adrenal- and 1 ectopic-origin; 21 active disease and 77 age-, gender-, smoking-matched controls were included. Total white blood cell TL was measured by TRF-Southern technique. Clinical data and blood samples were collected (lipids, adrenal function, glucose. Adiponectin, interleukin-6 (IL6 and C-reactive protein (CRP were available in a subgroup of patients (n=32. Correlations between TL and clinical features were examined and multiple linear regression analysis was performed to investigate potential predictors of TL.Dyslipidemic CS had shorter TL than non-dyslipidemic subjects (7328±1274 vs 7957±1137 bp, p<0.05. After adjustment for age and body mass index, cured and active CS dyslipidemic patients had shorter TL than non-dyslipidemic CS (cured: 7187±1309 vs 7868±1104; active: 7203±1262 vs 8615±1056, respectively, p<0.05. Total cholesterol and triglycerides negatively correlated with TL (r-0.279 and -0.259, respectively, p<0.05, as well as CRP and IL6 (r-0.412 and -0.441, respectively, p<0.05. No difference in TL according the presence of other individual CVR factors (hypertension, diabetes mellitus, obesity were observed in CS or in the control group. Additional TL shortening was observed in dyslipidemic obese patients who were also hypertensive, compared to those with two or less CVR factors (6956±1280 vs 7860±1180, respectively, p<0.001. Age and dyslipidemia were independent negative predictors of TL.TL is shortened in dyslipidemic CS

  20. Stability of Tl-Ba-Ca-Cu-O Superconducting Thin Films

    Energy Technology Data Exchange (ETDEWEB)

    Siegal, M.P.; Overmyer, D.L.; Venturini, E.L.; Padilla, R.R.; Provencio, P.N.

    1999-08-23

    We report the stability of TlBa{sub 2}CaCu{sub 2}O{sub 7} (Tl-1212) and Tl{sub 2}Ba{sub 2}CaCu{sub 2}O{sub 8} (T1-2212) thin films and by inference, the stability of TlBa{sub 2}Ca{sub 2}Cu{sub 3}O{sub 9} (Tl-1223) and Tl{sub 2}Ba{sub 2}Ca{sub 2}Cu{sub 3}O{sub 10} (Tl-2223) thin films, under a variety of conditions. In general, we observe that the stability behavior of the single Tl-O layer materials (Tl-1212 and Tl-1223)are similar and the double Tl-O layer materials (Tl-2212 and Tl-2223) are similar. All films are stable with repeated thermal cycling to cryogenic temperatures. Films are also stable in acetone and methanol. Moisture degrades film quality rapidly, especially in the form of vapor. Tl-1212 is more sensitive to vapor than Tl-2212. These materials are stable to high temperatures in either N{sub 2}, similar to vacuum for the cuprates, and O{sub 2} ambients. While total degradation of properties (superconducting and structural) occur at the same temperatures for all phases, 600 C in N{sub 2} and 700 C in O{sub 2}, the onset of degradation occurs at somewhat lower temperatures for Tl-1212 than for Tl-2212 films. In all cases, sample degradation is associated with Tl depletion from the films.

  1. Spectral measurements of loess TL

    International Nuclear Information System (INIS)

    Rendell, H.M.; Mann, S.J.; Townsend, P.D.

    1988-01-01

    Variations in thermoluminescence (TL) glow curves are reported for two loess samples when examined with broad band filters in the range 275-650 nm. Samples show striking differences in bleaching behaviour, when their TL emissions are observed in the u.v., blue, green and yellow spectral regions. The age estimates, given by the equivalent dose (ED) values, differ by up to a factor of two for analyses using the green and u.v. TL signals. These ED values also vary with prolonged room temperature storage between the bleaching and irradiation steps. The anomalies in the bleaching behaviour are interpreted in terms of changes in TL efficiency. The results have major implications for the regeneration method of TL dating for these fine-grained sediments and suggest that reliable dates obtained by it may be fortuitous. (author)

  2. 201Tl heart studies

    International Nuclear Information System (INIS)

    Bell, R.L.

    1976-01-01

    At the annual meeting of the Society of Nuclear Medicine there was a preponderance of papers dealing with the heart. The most impressive papers detailed the use of monovalent cation 201 Tl in the evaluation of coronary artery disease. Thallium-201 behaves like potassium in that it enters heart muscle quickly and persists in that organ for several hours. It is unlike most radioactive potassium analogues used for heart studies in that: (1) its gamma energy peaks (69 keV and 80 keV) are more easily collimated with resultant image improvement, (2) its physical half life of 72 hours is sufficiently short to attain high counting rates without too much radiation and is sufficiently long so that storage is not prohibitive, (3) its short half life and lack of Beta radiation results in lower radiation to the patient, and (4) its uptake in heart is greater and uptake in liver and stomach less than other potassium analogues

  3. Chemical bonding in Tl cuprates studied by x-ray photoemission

    International Nuclear Information System (INIS)

    Vasquez, R.P.; Siegal, M.P.; Overmyer, D.L.; Ren, Z.F.; Lao, J.Y.; Wang, J.H.

    1999-01-01

    Epitaxial thin films of the Tl cuprate superconductors Tl 2 Ba 2 CaCu 2 O 8 , Tl 2 Ba 2 Ca 2 Cu 3 O 10 , and Tl 0.78 Bi 0.22 Ba 0.4 Sr 1.6 Ca 2 Cu 3 O 9-δ are studied with x-ray photoemission spectroscopy. These data, together with previous measurements in this lab of Tl 2 Ba 2 CuO 6+δ and TlBa 2 CaCu 2 O 7-δ , comprise a comprehensive data set for a comparative study of Tl cuprates with a range of chemical and electronic properties. In the Cu 2p spectra, a larger energy separation between the satellite and main peaks (E s -E m ) and a lower intensity ratio (I s /I m ) are found to correlate with higher values of T c . Analysis of these spectra within a simple configuration interaction model suggests that higher values of T c are related to low values of the O 2p→Cu 3d charge transfer energy. In the O 1s region, a smaller bond length between Ba and Cu-O planar oxygen is found to correlate with a lower binding energy for the signal associated with Cu-O bonding, most likely resulting from the increased polarization screening by Ba 2+ ions. For samples near optimum doping, maximum T c is observed to occur when the Tl 4f 7/2 binding energy is near 117.9 eV, which is near the middle of the range of values observed for Tl cuprates. Higher Tl 4f 7/2 binding energies, corresponding to formal oxidation states nearer Tl 1+ , are also found to correlate with longer bond lengths between Ba and Tl-O planar oxygen, and with higher binding energies of the O 1s signal associated with Tl-O bonding. copyright 1999 The American Physical Society

  4. Allometric relations of total volumes of prolactin cells and corticotropic cells to body length in the annual cyprinodont Cynolebias whitei: effects of environmental salinity, stress and ageing

    NARCIS (Netherlands)

    Ruijter, J. M.; Wendelaar Bonga, S. E.

    1987-01-01

    An analysis of the allometric relations of the total volumes occupied by prolactin (PRL) and corticotropic (ACTH) cells (PRL volume and ACTH volume, respectively) to body length and a study of the immunocytochemical staining intensity of PRL and ACTH cells were used to determine the differences in

  5. Prediction of half-metallic properties in TlCrS{sub 2} and TlCrSe{sub 2} based on density functional theory

    Energy Technology Data Exchange (ETDEWEB)

    Hashimzade, F.M.; Huseinova, D.A. [Institute of Physics, National Academy of Sciences of Azerbaijan, AZ 1143 Baku (Azerbaijan); Jahangirli, Z.A. [Institute of Physics, National Academy of Sciences of Azerbaijan, AZ 1143 Baku (Azerbaijan); Institute of Radiation Problems, National Academy of Sciences of Azerbaijan, AZ 1143 Baku (Azerbaijan); Mehdiyev, B.H., E-mail: bachschi@yahoo.de [Institute of Physics, National Academy of Sciences of Azerbaijan, AZ 1143 Baku (Azerbaijan)

    2017-08-01

    Highlights: • Half-metallic properties of TlCrS2, TlCrSe2 and hypothetical TlCrSSe have been investigated by first-principles all-electron full-potential linearized augmented plane wave plus local orbital (FP-LAPW+lo) method based on density functional theory (DFT). • Total magnetic moment keeps its integer value on a relatively wide range of changes in volume (−10% ÷ 10%) for TlCrS2 and TlCrSSe, while total magnetic moment TlCrSe2 decreases with increasing volume, approaching to integer value 3 μB. • The states at the Fermi level in the case of spin-up channel consist of a hybridization of p-states of the atom S(Se) with d-states of Cr. - Abstract: Half-metallic properties of TlCrS{sub 2}, TlCrSe{sub 2} and hypothetical TlCrSSe have been investigated by first-principles all-electron full-potential linearized augmented plane wave plus local orbital (FP-LAPW+lo) method based on density functional theory (DFT). The results of calculations show that TlCrS{sub 2} and TlCrSSe are half-metals with energy gap (E{sub g}) ∼0.12 eV for spin-down channel. Strong hybridization of p-state of chalchogen and d-state of Cr leads to bonding and antibonding states and subsequently to the appearance of a gap in spin-down channel of TlCrS{sub 2} and TlCrSSe. In the case of TlCrSe{sub 2}, there is a partial hybridization and p-state is partially present in the DOS at Fermi level making this compound nearly half-metallic. The present calculations revealed that total magnetic moment keeps its integer value on a relatively wide range of changes in volume (−10% ÷ 10%) for TlCrS{sub 2} and TlCrSSe, while total magnetic moment of TlCrSe{sub 2} decreases with increasing volume approaching to integer value 3 μB.

  6. Length-weight and length-length relationships of common carp (Cyprinus carpio L.) in the middle and southern Iraq provinces

    Science.gov (United States)

    Al-jebory, Taymaa A.; Das, Simon K.; Usup, Gires; Bakar, Y.; Al-saadi, Ali H.

    2018-04-01

    In this study, length-weight and length-length relationships of common carp (Cyprinus carpio L.) in the middle and southern Iraq provinces were determined. Fish specimens were procured from seven provinces from July to December, 2015. A negative and positive allometric growth pattern was obtained, where the total length (TL) ranged from 25.60 cm to 33.53 cm, and body weight (BW) ranged from 700 g to 1423 g. Meanwhile, the lowest of 1.03 and highest of 3.54 in "b" value was recorded in group F and group C, respectively. Therefore, Fulton condition factor (K) range from 2.57 to 4.94. While, relative condition factor (Kn) was in the ranged of 0.95 to 1.01. A linear relationship between total length (TL) and standard length (SL) among the provinces for fish groups was obtained. The variances in "b" value ranged from 0.10 to 0.93 with correlation coefficient (r2) of 0.02 to 0.97. This research could be used as a guide to study the ecology and biology of common Carp (Cyprinus carpio L.) in the middle and southern Iraq provinces.

  7. Reducing Length of Stay, Direct Cost, and Readmissions in Total Joint Arthroplasty Patients With an Outcomes Manager-Led Interprofessional Team.

    Science.gov (United States)

    Arana, Melissa; Harper, Licia; Qin, Huanying; Mabrey, Jay

    The purpose of this quality improvement project was to determine whether an outcomes manager-led interprofessional team could reduce length of stay and direct cost without increasing 30-day readmission rates in the total joint arthroplasty patient population. The goal was to promote interprofessional relationships combined with collaborative practice to promote coordinated care with improved outcomes. Results from this project showed that length of stay (total hip arthroplasty [THA] reduced by 0.4 days and total knee arthroplasty [TKA] reduced by 0.6 days) and direct cost (THA reduced by $1,020 per case and TKA reduced by $539 per case) were significantly decreased whereas 30-day readmission rates of both populations were not significantly increased.

  8. Decreased length of stay and earlier oral feeding associated with standardized postoperative clinical care for total gastrectomies at a cancer center.

    Science.gov (United States)

    Selby, Luke V; Rifkin, Marissa B; Yoon, Sam S; Ariyan, Charlotte E; Strong, Vivian E

    2016-09-01

    Standardization of postoperative care has been shown to decrease postoperative length of stay. In June 2009, we standardized postoperative care for all gastrectomies at our institution. Four years' worth of total gastrectomies (2 years prior to standardization and 2 years after standardization) were reviewed to determine the effect of standardization on postoperative care, length of stay, complications, and readmissions. Between June 2007 and July 2011, 99 patients underwent curative intent open total gastrectomy: 51 patients prior to standardization, and 48 patients poststandardization. Patients were predominantly male (70%); median age was 63; and median body mass index was 26. Standardization of postoperative care was associated with a decrease in median time to beginning both clear liquids and a postgastrectomy diet, earlier removal of epidural catheters, earlier use of oral pain medication, less time receiving intravenous fluids, and decreased length of stay (all P Care Center, or readmission. Institution of standardized postoperative orders for total gastrectomy was associated with a significantly decreased length of stay and earlier oral feeding without increasing postoperative complications, early postoperative outpatient visits, or readmissions. Copyright © 2016 Elsevier Inc. All rights reserved.

  9. Regional variation in acute care length of stay after orthopaedic surgery total joint replacement surgery and hip fracture surgery.

    Science.gov (United States)

    Fitzgerald, John D; Weng, Haoling H; Soohoo, Nelson F; Ettner, Susan L

    2013-01-01

    To examine change in regional variations in acute care length of stay (LOS) after orthopedic surgery following expiration of the New York (NY) State exemption to the Prospective Payment System and implementation of the Medicare Short Stay Transfer Policy. Time series analyses were conducted to evaluate change in LOS across regions after policy implementations. Small area analyses were conducted to examine residual variation in LOS. The dataset included A 100% sample of fee-for-service Medicare patients undergoing surgical repair for hip fracture or elective joint replacement surgery between 1996 and 2001. Data files from Centers for Medicare and Medicaid Services 1996-2001 Medicare Provider Analysis and Review file, 1999 Provider of Service file, and data from the 2000 United States Census were used for analysis. In 1996, LOS in NY after orthopedic procedures was much longer than the remainder of the country. After policy changes, LOS fell. However, significant residual variation in LOS persisted. This residual variation was likely partly explained by differences variation in regional managed care market penetration, patient management practices and unmeasured characteristics associated with the hospital location. NY hospitals responded to changes in reimbursement policy, reducing variation in LOS. However, even after 5 years of financial pressure to constrain costs, other factors still have a strong impact on delivery of patient care.

  10. Spectrophotometric determination of Tl carrier in 201Tl-TlCl injection

    International Nuclear Information System (INIS)

    Gong Quansheng; Jing Lie

    1997-01-01

    A simple and sensitive method for the spectrophotometric determination of carrier content (Thallium) in 201 Tl-TlCl injection is described. Thallium (I) is oxidised to Thallium (III) by aqueous bromine, then excess bromine is removed by adding sulfosalicylic acid. In buffer solution (NH 4 Cl-NH 4 OH) at pH 11.7 with the presence of emulsifier OP, thallium (III) and cadion form a complex having an absorption maximum at 469 nm with a molar absorptivity of 1.37 x 10 4 m 2 /mol. Beer's law is obeyed in the concentration range of 0-7 μg/5 mL. The effect of impurity elements in 201 Tl-TlCl injection is examined. It is an ideal method for the analysis of radioactive solution

  11. Anisotropic superconducting state parameters of Tl-2212 superconductors

    International Nuclear Information System (INIS)

    Khaskalam, Amit K.; Singh, R.K.; Varshney, Dinesh

    2001-01-01

    We have estimated the superconducting state parameters and their anisotropy in thallium based superconductors (Tl-2212), in the frame work of Fermi liquid approach. Determination of the effective mass of the charge carriers from the Fermi velocity and estimated anisotropic superconducting state parameters, particularly, the magnetic penetration depth along and perpendicular to the conducting plane. The coherence length along and perpendicular to the ab plane is evaluated and appears to be higher. The temperature dependence of penetration depth, their anisotropy and Ginsburg Landau parameter for optimised doped Tl based cuprates shows the power law. The technique permits a consistency with the reported data. (author)

  12. A genome-wide association scan (GWAS) for mean telomere length within the COGS project: identified loci show little association with hormone-related cancer risk

    Science.gov (United States)

    Pooley, Karen A.; Bojesen, Stig E.; Weischer, Maren; Nielsen, Sune F.; Thompson, Deborah; Amin Al Olama, Ali; Michailidou, Kyriaki; Tyrer, Jonathan P.; Benlloch, Sara; Brown, Judith; Audley, Tina; Luben, Robert; Khaw, K-T; Neal, David E.; Hamdy, Freddie C.; Donovan, Jenny L.; Kote-Jarai, Zsofia; Baynes, Caroline; Shah, Mitul; Bolla, Manjeet K.; Wang, Qin; Dennis, Joe; Dicks, Ed; Yang, Rongxi; Rudolph, Anja; Schildkraut, Joellen; Chang-Claude, Jenny; Burwinkel, Barbara; Chenevix-Trench, Georgia; Pharoah, Paul D. P.; Berchuck, Andrew; Eeles, Rosalind A.; Easton, Douglas F.; Dunning, Alison M.; Nordestgaard, Børge G.

    2013-01-01

    Mean telomere length (TL) in blood cells is heritable and has been reported to be associated with risks of several diseases, including cancer. We conducted a meta-analysis of three GWAS for TL (total n=2240) and selected 1629 variants for replication via the “iCOGS” custom genotyping array. All ∼200 000 iCOGS variants were analysed with TL, and those displaying associations in healthy controls (n = 15 065) were further tested in breast cancer cases (n = 11 024). We found a novel TL association (Ptrend < 4 × 10−10) at 3p14.4 close to PXK and evidence (Ptrend < 7 × 10−7) for TL loci at 6p22.1 (ZNF311) and 20q11.2 (BCL2L1). We additionally confirmed (Ptrend < 5 × 10−14) the previously reported loci at 3q26.2 (TERC), 5p15.3 (TERT) and 10q24.3 (OBFC1) and found supportive evidence (Ptrend < 5 × 10−4) for the published loci at 2p16.2 (ACYP2), 4q32.2 (NAF1) and 20q13.3 (RTEL1). SNPs tagging these loci explain TL differences of up to 731 bp (corresponding to 18% of total TL in healthy individuals), however, they display little direct evidence for association with breast, ovarian or prostate cancer risks. PMID:23900074

  13. A genome-wide association scan (GWAS) for mean telomere length within the COGS project: identified loci show little association with hormone-related cancer risk.

    Science.gov (United States)

    Pooley, Karen A; Bojesen, Stig E; Weischer, Maren; Nielsen, Sune F; Thompson, Deborah; Amin Al Olama, Ali; Michailidou, Kyriaki; Tyrer, Jonathan P; Benlloch, Sara; Brown, Judith; Audley, Tina; Luben, Robert; Khaw, K-T; Neal, David E; Hamdy, Freddie C; Donovan, Jenny L; Kote-Jarai, Zsofia; Baynes, Caroline; Shah, Mitul; Bolla, Manjeet K; Wang, Qin; Dennis, Joe; Dicks, Ed; Yang, Rongxi; Rudolph, Anja; Schildkraut, Joellen; Chang-Claude, Jenny; Burwinkel, Barbara; Chenevix-Trench, Georgia; Pharoah, Paul D P; Berchuck, Andrew; Eeles, Rosalind A; Easton, Douglas F; Dunning, Alison M; Nordestgaard, Børge G

    2013-12-15

    Mean telomere length (TL) in blood cells is heritable and has been reported to be associated with risks of several diseases, including cancer. We conducted a meta-analysis of three GWAS for TL (total n=2240) and selected 1629 variants for replication via the "iCOGS" custom genotyping array. All ∼200 000 iCOGS variants were analysed with TL, and those displaying associations in healthy controls (n = 15 065) were further tested in breast cancer cases (n = 11 024). We found a novel TL association (Ptrend < 4 × 10(-10)) at 3p14.4 close to PXK and evidence (Ptrend < 7 × 10(-7)) for TL loci at 6p22.1 (ZNF311) and 20q11.2 (BCL2L1). We additionally confirmed (Ptrend < 5 × 10(-14)) the previously reported loci at 3q26.2 (TERC), 5p15.3 (TERT) and 10q24.3 (OBFC1) and found supportive evidence (Ptrend < 5 × 10(-4)) for the published loci at 2p16.2 (ACYP2), 4q32.2 (NAF1) and 20q13.3 (RTEL1). SNPs tagging these loci explain TL differences of up to 731 bp (corresponding to 18% of total TL in healthy individuals), however, they display little direct evidence for association with breast, ovarian or prostate cancer risks.

  14. Psychological Profiles in the Prediction of Leukocyte Telomere Length in Healthy Individuals.

    Directory of Open Access Journals (Sweden)

    Louisia Starnino

    Full Text Available Shorter telomere length (TL may signal premature cellular aging and increased risk for disease. While depression and psychosocial stress have been associated with shorter telomeres, other psychological risk factors for cardiovascular disease have received less attention.To evaluate the association between TL and psychological risk factors (symptoms of anxiety and depression, hostility and defensiveness traits for heart disease, and to examine whether chronological age and sex moderate the associations observed.132 healthy men and women (Mage = 45.34 years completed the Marlowe-Crowne Social Desirability Scale, the Beck Depression Inventory II, The Beck Anxiety Inventory and the Cook-Medley Hostility Scale. Relative TL was measured by quantitative polymerase chain reaction (PCR of total genomic DNA samples. A series of hierarchical linear regressions were performed controlling for pertinent covariates.Shorter TL was observed among individuals high in defensiveness (β = -.221 and depressive symptoms (β = -.213, as well as in those with less hostility (β =.256 and anxiety (β =.220(all Ps<.05. Psychological variables explained 19% of the variance over and above that explained by covariates (age, sex, exercise, alcohol consumption, systemic inflammation, and 24-hr mean arterial pressure. Age moderated the relation between TL and defensiveness (β =.179, p =.03. Sex did not influence any of the relations.Telomere length is associated with psychological burden though the direction of effect differs depending on the psychological variables under study. Further research is needed to determine the reasons for and implications of these seemingly contradictory findings.

  15. The length-weight and length-length relationships of bluefish, Pomatomus saltatrix (Linnaeus, 1766 from Samsun, middle Black Sea region

    Directory of Open Access Journals (Sweden)

    Melek Özpiçak

    2017-10-01

    Full Text Available In this study, length-weight relationship (LWR and length-length relationship (LLR of bluefish, Pomatomus saltatrix were determined. A total of 125 specimens were sampled from Samsun, the middle Black Sea in 2014 fishing season. Bluefish specimens were monthly collected from commercial fishing boats from October to December 2014. All captured individuals (N=125 were measured to the nearest 0.1 cm for total, fork and standard lengths. The weight of each fish (W was recorded to the nearest 0.01 g. According to results of analyses, there were no statistically significant differences between sexes in term of length and weight (P˃0.05. The minimum and maximum total, fork and standard lengths of bluefish ranged between 13.5-23.6 cm, 12.50-21.80 cm and 10.60-20.10 cm, respectively. The equation of length-weight relationship were calculated as W=0.008TL3.12 (r2>0.962. Positive allometric growth was observed for bluefish (b>3. Length-length relationship was also highly significant (P<0.001 with coefficient of determination (r2 ranging from 0.916 to 0.988.

  16. Tl Cuprate Superconductors Studied by XPS

    Energy Technology Data Exchange (ETDEWEB)

    Vasquez, R. P. [Jet Propulsion Laboratory, California Institute of Technology, Pasadena, CA 91109-8099 (United States); Siegal, M. P. [Sandia National Laboratories, Albuquerque, NM 87185-1421 (United States); Overmyer, D. L. [Sandia National Laboratories, Albuquerque, NM 87185-1421 (United States); Ren, Z. F. [Department of Chemistry, State University of New York, Buffalo, NY 14260-3000 (United States); Lao, J. Y. [Department of Chemistry, State University of New York, Buffalo, NY 14260-3000 (United States); Wang, J. H. [Department of Chemistry, State University of New York, Buffalo, NY 14260-3000 (United States)

    1999-07-01

    XPS measurements on epitaxial thin films of the Tl cuprate superconductors Tl2Ba2CaCu2O8, Tl2Ba2Ca2Cu3O10, and Tl0.78Bi0.22Ba0.4Sr1.6Ca2Cu3O9-{delta} are presented. These data, together with previous measurements in this lab on Tl2Ba2CuO6-{delta} and TlBa2CaCu2O7-{delta}, comprise a comprehensive data set for comparison of Tl cuprates in which the number of Tl-O and Cu-O layers, and hence the chemical and electronic properties, vary. (c) 2000 American Vacuum Society.

  17. Tl Cuprate Superconductors Studied by XPS

    International Nuclear Information System (INIS)

    Vasquez, R. P.; Siegal, M. P.; Overmyer, D. L.; Ren, Z. F.; Lao, J. Y.; Wang, J. H.

    1999-01-01

    XPS measurements on epitaxial thin films of the Tl cuprate superconductors Tl2Ba2CaCu2O8, Tl2Ba2Ca2Cu3O10, and Tl0.78Bi0.22Ba0.4Sr1.6Ca2Cu3O9-δ are presented. These data, together with previous measurements in this lab on Tl2Ba2CuO6-δ and TlBa2CaCu2O7-δ, comprise a comprehensive data set for comparison of Tl cuprates in which the number of Tl-O and Cu-O layers, and hence the chemical and electronic properties, vary. (c) 2000 American Vacuum Society

  18. The total body length and body weight examination among gabus Sentani fish population, Oxyeleotris heterodon, Weber 1907 (Pisces: Eleotridae) of Sentani lake, Papua, Indonesia

    Science.gov (United States)

    Sriyani, E. D.; Abinawanto, Bowolaksono, A.

    2017-07-01

    The gabus Sentani fish lived in the Sentani Lake, Papua, since million years ago. Nowadays, the population of those species is getting extinct because of the overexploitation, whereas the culture effort of this species has not been developed, yet. The purpose of the study was to examine the total body length and body weight collected from some villages surrounding Sentani Lake such as Ifar village, Sosiri village, and Putali village. The body weight average of gabus fish from Ifar village, Sosiri village, and Putali village were 373.53 g, 426.86 g, and 118.34 g respectively. While the total body length average of gabus Sentani fish from Ifar village, Sosiri village, and Putali village were 279.30 mm, 223.30 mm and 222.06 mm, respectively. The growth model was W = 0.021067L3.086 with R2 value was 35.8 %, and r value was 0.598. Gabus Sentani fish, Oxyeleotris heterodon (Weber 1907) exhibited positive allometric (b > 3).

  19. Magnetism and superconductivity of some Tl-Cu oxides

    Science.gov (United States)

    Datta, Timir

    1991-01-01

    Many copper oxide based Thallium compounds are now known. In comparison to the Bi-compounds, the Tl-system shows a richer diversity; i.e., High Temperature Superconductors (HTSC) can be obtained with either one or two Tl-0 layers (m = 1,2); also, the triple-digit phases are easier to synthesize. The value of d, oxygen stoichiometry, is critical to achieving superconductivity. The Tl system is robust to oxygen loss; Tl may be lost or incorporated by diffusion. A diffusion coefficient equal to 10 ms at 900 C was determined. Both ortho-rhombic and tetragonal structures are found, but HTSC behavior is indifferent to the crystal symmetry. This system has the highest T(sub c) confirmed. T(sub c) generally increases with p, the number of CuO layers, but tends to saturate at p = 3. Zero resistance was observed at temperatures as great as 125 K. Most of these HTSC's are hole type, but the Ce-doped specimens may be electronic. The magnetic aspects were studied; because in addition to defining the perfectly diamagnetic ground state as in conventional superconductors, magnetism of the copper oxides show a surprising variety. This is true of both the normal and the superconducting states. Also, due to the large phonon contribution to the specific heat at the high T(sub c) jump, electronic density of states, D(Ef), and coherence length are uncertain, and thus, are estimated from the magnetic results. Results from the Tl-system CuO, LaBaCuO,120 and the Bi-CuO compounds are discussed. The emphasis is on the role of magnetism in the Tl-CuO HTSC, but technological aspects are also pointed out.

  20. Validation and dosimetric evaluation employing the techniques of TL and OSL of thermoluminescent materials for application in the dosimetry of clinical beams of electrons used in total irradiation of the skin - TSI; Validação e avaliação dosimétrica empregando as técnicas de TL e OSL de materiais termoluminescentes para aplicação na dosimetria de feixes clínicos de elétrons utilizados na irradiação total da pele

    Energy Technology Data Exchange (ETDEWEB)

    Almeida, Shirlane Barbosa de

    2017-07-01

    In vivo dosimetry has become an important role for the treatment of total skin irradiation within a rigorous quality assurance program that should be an integral part of the radiotherapy departments. TSI dosimetry is difficult because of the complexity of the treatment in assessing dose uniformity and measuring the dose absorbed at shallow depths throughout the skin surface extent, resulting in a wide variation in dose distribution. The TLDs have proven to be very useful for the distribution and verification of the dose prescribed for the patient as the dose may differ from place to place due to patient body geometry, overlapping of structures and asymmetries of the radiation field. The use of TLDs in vivo can identify variations in the prescribed dose because its measurement accuracy and great precision. Several types of dosimeters have been used in the radiotherapy sectors, the most commonly used are Lithium Fluride (TLD-100), where it obtains a long history in this type of application. New dosimetric materials have gained great importance in the dosimetry of clinical electron beams, such as Dysprosium-doped Calcium Sulphate (TL) and Carbon doped (OSL) based Aluminum Oxide, This work evaluates the performance of the respective thermoluminescent dosimeters and the optically stimulated luminescence in the dosimetry of clinical electron beams used in total irradiation of the skin. (author)

  1. M1 transitions between superdeformed states in 195Tl

    International Nuclear Information System (INIS)

    Zheng Xing; Xingqu Chen; Xiaochun Wang

    1996-01-01

    Using a triaxial-particle-rotor model, the quadrupole and dipole transition energies, kinematic and dynamic moments of inertia, electromagnetic transition probabilities and the relative intensity of the E2 γ-transitions are calculated for superdeformed bands in 195 Tl. A strong perturbation effect of rotation on transition energies and M1 and E2 transitions of superdeformed states is investigated. The total M1 transitions, enhanced by internal conversion, are expected to compete strongly with the E2 γ-ray at low spins in the superdeformed 195 Tl nucleus. (author)

  2. Effect of day of the week of primary total hip arthroplasty on length of stay at a university-based teaching medical center.

    Science.gov (United States)

    Rathi, Pranav; Coleman, Sheldon; Durbin-Johnson, Blythe; Giordani, Mauro; Pereira, Gavin; Di Cesare, Paul E

    2014-12-01

    Length of hospital stay (LHS) after primary total hip arthroplasty (THA) constitutes a critical outcome measure, as prolonged LHS implies increased resource expenditure. Investigations have highlighted factors that affect LHS after THA. These factors include advanced age, medical comorbidities, obesity, intraoperative time, anesthesia technique, surgical site infection, and incision length. We retrospectively analyzed the effect of day of the week of primary THA on LHS. We reviewed the surgery and patient factors of 273 consecutive patients who underwent THA at our institution, a tertiary-care teaching hospital. There was a 15% increase in LHS for patients who underwent THA on Thursday versus Monday when controlling for other covariates that can affect LHS. Other statistically significant variables associated with increased LHS included American Society of Anesthesiologists grade, transfusion requirements, and postoperative complications. The day of the week of THA may be an independent variable affecting LHS. Institutions with reduced weekend resources may want to perform THA earlier in the week to try to reduce LHS.

  3. Lattice distortions in TlInSe{sub 2} thermoelectric material studied by X-ray absorption fine structure

    Energy Technology Data Exchange (ETDEWEB)

    Hosokawa, Shinya; Stellhorn, Jens Ruediger [Department of Physics, Kumamoto University, Kumamoto (Japan); Ikemoto, Hiroyuki [Department of Physics, University of Toyama, Toyama (Japan); Mimura, Kojiro [Department of Mathematical Sciences, Graduate School of Engineering, Osaka Prefecture University, Sakai (Japan); Wakita, Kazuki [Faculty of Engineering, Chiba Institute of Technology, Narashino (Japan); Mamedov, Nazim [Institute of Physics, Azerbaijan National Academy of Sciences, Baku (Azerbaijan)

    2018-01-15

    Tl L{sub II} and In K X-ray absorption fine structure (XAFS) measurements were performed on a TlInSe{sub 2} thermoelectric material in the temperature range of 25-300 K including the incommensurate-commensurate phase transition temperature of about 135 K. Most of the bond lengths obtained from the present XAFS measurements are in good agreement with existing X-ray diffraction data at room temperature, while only the Tl-Tl correlation shows inconsistent values indicating the commensurate properties of the Tl chains expected from the thermodynamic properties. The present XAFS data clearly support positional fluctuations of the Tl atoms found in three-dimensional atomic images reconstructed from X-ray fluorescence holography. (copyright 2017 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  4. The influence of NDT-Bobath and PNF methods on the field support and total path length measure foot pressure (COP) in patients after stroke.

    Science.gov (United States)

    Krukowska, Jolanta; Bugajski, Marcin; Sienkiewicz, Monika; Czernicki, Jan

    In stroke patients, the NDT - (Bobath - Neurodevelopmental Treatment) and PNF (Proprioceptive Neuromuscular Facilitation) methods are used to achieve the main objective of rehabilitation, which aims at the restoration of maximum patient independence in the shortest possible period of time (especially the balance of the body). The aim of the study is to evaluate the effect of the NDT-Bobath and PNF methods on the field support and total path length measure foot pressure (COP) in patients after stroke. The study included 72 patients aged from 20 to 69 years after ischemic stroke with Hemiparesis. The patients were divided into 4 groups by a simple randomization. The criteria for this division were: the body side (right or left) affected by paresis and the applied rehabilitation methods. All the patients were applied the recommended kinesitherapeutic method (randomized), 35 therapy sessions, every day for a period of six weeks. Before initiation of therapy and after 6 weeks was measured the total area of the support and path length (COP (Center Of Pressure) measure foot pressure) using stabilometer platform - alpha. The results were statistically analyzed. After treatment studied traits decreased in all groups. The greatest improvement was obtained in groups with NDT-Bobath therapy. NDT-Bobath method for improving the balance of the body is a more effective method of treatment in comparison with of the PNF method. In stroke patients, the effectiveness of NDT-Bobath method does not depend on hand paresis. Copyright © 2016 Polish Neurological Society. Published by Elsevier Urban & Partner Sp. z o.o. All rights reserved.

  5. The Length-Weight, Length-Length Relationship and Condition Factor of Angora Loach, Oxynoemacheilus angorae (Steindachner, 1897 Inhabiting Kılıçözü Stream in Kızılırmak River Basin (Central Anatolia-Turkey

    Directory of Open Access Journals (Sweden)

    Okan Yazıcıoğlu

    2016-12-01

    Full Text Available In this study, length-weight relationship (LWR, length- length relationship (LLR and condition factor (K of Angora loach, Oxynoemacheilus angorae were determined. A total of 103 specimens were sampled from Kılıçözü Stream in 2014. The length and weight of specimens were ranged 3.5-9.8 cm and 0.38-6.58 g, respectively. Length-weight relationships for female, male and all samples were found as W= 0.01056.TL2.896 (r²= 0.923, W= 0.00963.TL2.940 (r²= 0.978 and W= 0.00987.TL2.929 (r²= 0.963, respectively. LWRs indicated an isometric growth in female, male and all samples. The values of Fulton’s condition factor (K ranged from 0.699 to 1.246 for females and from 0.654 to 1.072 for males. All length-length relationships were statistically significant.

  6. Chemical Bonding in Tl Cuprates Studied by X-Ray Photoemission

    Energy Technology Data Exchange (ETDEWEB)

    Lao, J.Y.; Overmyer, D.L.; Ren, Z.F.; Siegal, M.P.; Vasquez, R.P.; Wang, J.H.

    1999-04-05

    Epitaxial thin films of the Tl cuprate superconductors Tl{sub 2}Ba{sub 2}CaCu{sub 2}O{sub 8}, Tl{sub 2}Ba{sub 2}Ca{sub 2}Cu{sub 3}O{sub 10}, and TL{sub 0.78}Bi{sub 0.22}Ba{sub 0.4}Sr{sub 1.6}Ca{sub 2}Cu{sub 3}O{sub 9{minus}{delta}} are studied with x-ray photoemission spectroscopy. These data, together with previous measurements in this lab of Tl{sub 2}Ba{sub 2}CuO{sub 6+{delta}} and TlBa{sub 2}CaCu{sub 2}O{sub 7{minus}{delta}}, comprise a comprehensive data set for a comparative study of Tl cuprates with a range of chemical and electronic properties. In the Cu 2p spectra, a larger energy separation between the satellite and main peaks (E{sub s}-E{sub m}) and a lower intensity ratio (I{sub s}/I{sub m}) are found to correlate with higher values of T{sub c}. Analysis of these spectra within a simple configuration interaction model suggests that higher values of T{sub c} are related to low values of the O 2p {r_arrow} Cu 3d charge transfer energy. In the O 1s region, a smaller bond length between Ba and Cu-O planar oxygen is found to correlate with a lower binding energy for the signal associated with Cu-O bonding, most likely resulting from the increased polarization screening by Ba{sup 2+} ions. For samples near optimum doping, maximum T{sub c} is observed to occur when the Tl 4f{sub 7/2} binding energy is near 117.9 eV, which is near the middle of the range of values observed for Tl cuprates. Higher Tl 4f{sub 7/2} binding energies, corresponding to formal oxidation states nearer Tl{sup 1+}, are also found to correlate with longer bond lengths between Ba and Tl-O planar oxygen, and with higher binding energies of the O 1s signal associated with Tl-O bonding.

  7. Chemical bonding in Tl cuprates studied by x-ray photoemission

    Energy Technology Data Exchange (ETDEWEB)

    Vasquez, R.P. [Center for Space Microelectronics Technology, Jet Propulsion Laboratory, California Institute of Technology, Pasadena, California 91109-8099 (United States); Siegal, M.P.; Overmyer, D.L. [Sandia National Laboratories, Albuquerque, New Mexico 87185-1421 (United States); Ren, Z.F.; Lao, J.Y.; Wang, J.H. [Materials Synthesis Laboratory, Department of Chemistry, State University of New York, Buffalo, New York 14260-3000 (United States)

    1999-08-01

    Epitaxial thin films of the Tl cuprate superconductors Tl{sub 2}Ba{sub 2}CaCu{sub 2}O{sub 8}, Tl{sub 2}Ba{sub 2}Ca{sub 2}Cu{sub 3}O{sub 10}, and Tl{sub 0.78}Bi{sub 0.22}Ba{sub 0.4}Sr{sub 1.6}Ca{sub 2}Cu{sub 3}O{sub 9{minus}{delta}} are studied with x-ray photoemission spectroscopy. These data, together with previous measurements in this lab of Tl{sub 2}Ba{sub 2}CuO{sub 6+{delta}} and TlBa{sub 2}CaCu{sub 2}O{sub 7{minus}{delta}}, comprise a comprehensive data set for a comparative study of Tl cuprates with a range of chemical and electronic properties. In the Cu 2p spectra, a larger energy separation between the satellite and main peaks (E{sub s}{minus}E{sub m}) and a lower intensity ratio (I{sub s}/I{sub m}) are found to correlate with higher values of T{sub c}. Analysis of these spectra within a simple configuration interaction model suggests that higher values of T{sub c} are related to low values of the O&hthinsp;2p{r_arrow}Cu&hthinsp;3d charge transfer energy. In the O&hthinsp;1s region, a smaller bond length between Ba and Cu-O planar oxygen is found to correlate with a lower binding energy for the signal associated with Cu-O bonding, most likely resulting from the increased polarization screening by Ba{sup 2+} ions. For samples near optimum doping, maximum T{sub c} is observed to occur when the Tl 4f{sub 7/2} binding energy is near 117.9 eV, which is near the middle of the range of values observed for Tl cuprates. Higher Tl&hthinsp;4f{sub 7/2} binding energies, corresponding to formal oxidation states nearer Tl{sup 1+}, are also found to correlate with longer bond lengths between Ba and Tl-O planar oxygen, and with higher binding energies of the O&hthinsp;1s signal associated with Tl-O bonding. {copyright} {ital 1999} {ital The American Physical Society}

  8. Converting Hg-1212 to Tl-2212 via Tl-Hg cation exchange in combination with Tl cation intercalation

    International Nuclear Information System (INIS)

    Zhao Hua; Wu, Judy Z

    2007-01-01

    In a cation exchange process developed recently for epitaxy of HgBa 2 CaCu 2 O 6 (Hg-1212) thin films, TlBa 2 CaCu 2 O 7 (Tl-1212) or Tl 2 Ba 2 CaCu 2 O 9 (Tl-2212) precursor films were employed as the precursor matrices and Hg-1212 was obtained by replacing Tl cations on the precursor lattice with Hg cations. The reversibility of the cation exchange dictates directly the underlying mechanism. Following our recent success in demonstrating a complete reversibility within '1212' structure, we show the conversion from Hg-1212 to Tl-2212 can be achieved via two steps: conversion from Hg-1212 to Tl-1212 followed by Tl intercalation to form double Tl-O plans in each unit cell. The demonstrated reversibility of the cation exchange process has confirmed the process is a thermal perturbation of weakly bonded cations on the lattice and the direction of the process is determined by the population ratio between the replacing cations and that to be replaced

  9. Stability of Tl-Ba-Ca-Cu-O superconducting thin films

    International Nuclear Information System (INIS)

    Siegal, M. P.; Overmyer, D. L.; Venturini, E. L.; Padilla, R. R.; Provencio, P. N.

    1999-01-01

    We report the stability of TlBa 2 CaCu 2 O 7 and Tl 2 Ba 2 CaCu 2 O 8 on LaAlO 3 (100) epitaxial thin films, under a variety of conditions. All films are stable in acetone and methanol and with repeated thermal cycling to cryogenic temperatures. Moisture, especially vapor, degrades film quality rapidly. These materials are stable to high temperatures in either N 2 or O 2 ambients. While total degradation, resulting from Tl depletion, occurs at the same temperatures for both phases, 600 degree sign C in N 2 and 700 degree sign C in O 2 , the onset of degradation occurs at somewhat lower temperatures for TlBa 2 CaCu 2 O 7 than for Tl 2 Ba 2 CaCu 2 O 8 . (c) 1999 Materials Research Society

  10. Determination of the full energy peak efficiency of NaI(Tl) detectors

    International Nuclear Information System (INIS)

    Cesana, A.; Terrani, M.

    1978-01-01

    A simple procedure for the accurate evaluation of the full energy peak efficiency of NaI(Tl) crystals is described. Particular attention is given to the peak to total ratio determination for which a new method is proposed. (author)

  11. Preparation of 199Tl using the electroplating gold targets on the internal target installation of cyclotron

    International Nuclear Information System (INIS)

    Zhou Dehai; Xie Degao; Chao Yangshu; Liao Fuquan; Zhang Youfa; Wang Zefu

    1992-01-01

    The separative conditions of 199 Tl from Cu, Au and Ga by reaction 197 Au(α, 2n) 199 Tl on the internal target installation of cyclotron is studied. The α-particle energy is selected in the range of 24-15 MeV. The cumulative current intensities of such α-particle beams bombarding the gold target at 150-200 μA are 1200 μA · h and 1500 μA · h respectively. The radiochemical separation of 199 Tl is carried out with isopropyl ether extraction and anions exchange from the irradiated gold targets. The radioactivities of 199 Tl and 200 Tl are 2.3 x 10 5 Bq and 7.1 x 10 2 Bq, and 200 Tl makes up 0.29% of the total radioactivity. The impurity elements contained 1 ml of 199 TlCl injection solution are Au 199 TlCl has been used in clinical experiments in vivo and relatively good results have been obtained

  12. 201Tl in myocardial diagnosis: studies on the influence of dipyridamole, dobutamine ergometer exercise and background subtraction on the 201Tl myocadial scintiscam

    International Nuclear Information System (INIS)

    Seiderer, M.

    1979-01-01

    Changes in 201 Tl myocardial scintiscans upon administration of dipyridamole or dobutamine and upon ergometer exercise relative to scintiscans at rest were investigated as well as the influence of myocardial background subtraction on scintiscan quality and information. A total of 90 201 Tl examinations were carried out in 59 patients. 18 patients had no myocardial disease, 30 patients had a coronary disease, 5 patients suffered from cardiomyopathy and 6 from left ventricular hypertrophy. The findings are discussed in detail. (orig.) [de

  13. Superconducting transition in TlBiTe/sub 2/ and TlTe compounds

    Energy Technology Data Exchange (ETDEWEB)

    Kantser, V G; Popovich, N S; Sidorenko, A S

    1985-10-01

    On the basis of zone structure calculation for TlBiTe/sub 2/ and TlTe it is found that TlBiTe/sub 2/ is a narrow-gap semiconductor and TlTe is a p-metal. At Tsub(c)=0.19 K TlTe is found to experience the superconducting transition. In TlBiTe/sub 2/ superconductivity is not observed to occur up to 0.05 K, since there is a possibility of occupying the high density of states zones because they are remote from actual ones. The earlier discovered superconducting transition in TlBiTe/sub 2/ is inherent in the alien phase of TlTe.

  14. Trends in primary total hip arthroplasty in Spain from 2001 to 2008: Evaluating changes in demographics, comorbidity, incidence rates, length of stay, costs and mortality

    Directory of Open Access Journals (Sweden)

    Jimenez-Trujillo Isabel

    2011-02-01

    Full Text Available Abstract Background Hip arthroplasties is one of the most frequent surgical procedures in Spain and are conducted mainly in elderly subjects. We aim to analyze changes in incidence, co-morbidity profile, length of hospital stay (LOHS, costs and in-hospital mortality (IHM of patients undergoing primary total hip arthroplasty (THA over an 8-year study period in Spain. Methods We selected all surgical admissions in individuals aged ≥40 years who had received a primary THA (ICD-9-CM procedure code 81.51 between 2001 and 2008 from the National Hospital Discharge Database. Age- and sex-specific incidence rates, LOHS, costs and IHM were estimated for each year. Co-morbidity was assessed using the Charlson comorbidity index. Multivariate analysis of time trends was conducted using Poisson regression. Logistic regression models were conducted to analyze IHM. Results We identified a total of 161,791 discharges of patients having undergone THA from 2001 to 2008. Overall crude incidence had increased from 99 to 105 THA per 100.000 inhabitants from 2001 to 2008 (p 2 and in 2008, the prevalence of 1-2 or >2 had increased to 20.4% and 1.1% respectively (p Conclusions The current study provides clear and valid data indicating increased incidence of primary THA in Spain from 2001 to 2008 with concomitant reductions in LOHS, slight reduction IHM, but a significant increase in cost per patient. The health profile of the patient undergoing a THA seems to be worsening in Spain.

  15. Implementation of a Total Hip Arthroplasty Care Pathway at a High-Volume Health System: Effect on Length of Stay, Discharge Disposition, and 90-Day Complications.

    Science.gov (United States)

    Featherall, Joseph; Brigati, David P; Faour, Mhamad; Messner, William; Higuera, Carlos A

    2018-06-01

    Standardized care pathways are evidence-based algorithms for optimizing an episode of care. Despite the theoretical promise of care pathways, there is an inconsistent literature demonstrating improvements in patient care. The authors hypothesized that implementing a care pathway, across 11 hospitals, would decrease hospital length of stay (LOS), decrease postoperative complications at 90 days, and increase discharges to home. A multidisciplinary team developed an evidence-based care pathway for total hip arthroplasty (THA) perioperative care. All patients receiving THA in 2013 (pre-protocol, historical control), 2014 (transition), and 2015 (full protocol implementation) were included in the analysis. Multivariable regression assessed the relationship of the care pathway to 90-day postoperative complications, LOS, and discharge disposition. Cost savings were estimated using previously published postarthroplasty episode and per diem hospital costs. A total of 6090 primary THAs were conducted during the study period. After adjusting for the covariates, the full protocol implementation was associated with a decrease in LOS (mean ratio, 0.747; 95% confidence interval [CI; 0.727, 0.767]) and an increase in discharges to home (odds ratio, 2.079; 95% CI [1.762, 2.456]). The full protocol implementation was not associated with a change in 90-day complications (odds ratio, 1.023; 95% CI [0.841, 1.245]). Payer-perspective-calculated theoretical cost savings, including both index admission and postdischarge costs, were $2533 per patient. The THA care pathway implementation was successful in reducing LOS and increasing discharges to home. The care pathway was not associated with a change in 90-day complications; further targeted interventions in this area are needed. Despite care standardization efforts, high-volume hospitals and surgeons had higher performance. Extrapolation of theoretical cost savings indicates that widespread THA care pathway adoption could lead to national

  16. Study of /sup 201/Tl uptake by bone and bone marrow on /sup 201/Tl scintigraphy. With special reference to bone marrow abnormalities

    Energy Technology Data Exchange (ETDEWEB)

    Fujii, Tadashige; Tanaka, Masao; Hirose, Yoshiki; Hirayama, Jiro; Handa, Kenjiro; Nakanishi, Fumiko; Yano, Kesato; Ueda, Hitoshi

    1989-04-01

    Thallium-201 (Tl-201) uptake in the bone and bone marrow was examined in a total of 93 patients with various diseases. Sternal uptake of Tl-201 was observed when patients had bone marrow abnormality especially associated with hematopoietic disease. It was associated with proliferation of immature cells and of various types of bone marrow cells, especially erythroblastic and plasma cells. Whole-body Tl-201 scanning showed a high uptake (82%) in the sternum, chest, lumbar vertebrae, and pelvis. Thallium-201 was definitively taken up by the sternum in polycythemia (5/41), hemolytic anemia (2/2), iron deficiency anemia (2/2), and multiple myeloma (2/5). For leukemia, Tl-201 uptake was slight or negative. Thallium-201 scanning proved useful in visualizing bone marrow abnormality, although careful interpretation of bone and bone marrow uptake is required. (Namekawa, K).

  17. Prolate yrast cascade in 183Tl

    International Nuclear Information System (INIS)

    Reviol, W.; Carpenter, M. P.; Janssens, R. V. F.; Jenkins, D.; Toth, K. S.; Bingham, C. R.; Riedinger, L. L.; Weintraub, W.; Cizewski, J. A.; Lauritsen, T.

    2000-01-01

    The yrast sequence in 183 Tl has been studied for the first time in recoil-mass selected γ-ray spectroscopic measurements. A rotational-like cascade of seven transitions is established down to the band head with probable spin and parity (13/2 + ). Unlike in the adjacent odd-mass Tl nuclei, prompt γ decay from the yrast band to a lower lying weakly deformed (oblate) structure is not observed. These features are consistent with the predicted drop of the prolate band head in 183 Tl compared to 185 Tl. The implications for the prolate energy minimum in odd-mass Tl nuclei at the neutron i 13/2 midshell (N=103) are discussed. (c) 2000 The American Physical Society

  18. Association between preoperative anaemia with length of hospital stay among patients undergoing primary total knee arthroplasty in Singapore: a single-centre retrospective study.

    Science.gov (United States)

    Abdullah, Hairil Rizal; Sim, Yilin Eileen; Hao, Ying; Lin, Geng Yu; Liew, Geoffrey Haw Chieh; Lamoureux, Ecosse L; Tan, Mann Hong

    2017-06-08

    Studies in western healthcare settings suggest that preoperative anaemia is associated with poor outcomes after elective orthopaedic surgery. We investigated the prevalence of preoperative anaemia among patients with primary unilateral total knee arthroplasty (TKA) in Singapore and its association with length of hospital stay (LOS), perioperative blood transfusion and hospital readmission rates. Retrospective cohort study performed in a tertiary academic medical centre in Singapore, involving patients who underwent primary unilateral TKA between January 2013 and June 2014. Demographics, comorbidities, preoperative haemoglobin (Hb) level, LOS and 30-day readmission data were collected. Anaemia was classified according to WHO definition. Prolonged LOS was defined as more than 6 days, which corresponds to >75th centile LOS of the data. We analysed 2394 patients. The prevalence of anaemia was 23.7%. 403 patients (16.8%) had mild anaemia and 164 patients (6.8%) had moderate to severe anaemia. Overall mean LOS was 5.4±4.8 days. Based on multivariate logistic regression, preoperative anaemia significantly increased LOS (mild anaemia, adjusted OR (aOR) 1.71, p70 years were associated with prolonged LOS. Our 30-day related readmission rate was 1.7% (42) cases. Anaemia is common among patients undergoing elective TKA in Singapore and is independently associated with prolonged LOS and increased perioperative blood transfusion. We suggest measures to correct anaemia prior to surgery, including the use of non-gender-based Hb cut-off for establishing diagnosis. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  19. Does the nephrostomy tract length impact the outcomes of percutaneous nephrolithotomy (PNL)?

    Science.gov (United States)

    Astroza, Gaston M; Neisius, Andreas; Tsivian, Matvey; Wang, Agnes J; Preminger, Glenn M; Lipkin, Michael E

    2014-12-01

    Different factors can determine the outcomes of percutaneous nephrolithotomy (PNL). We analyzed the effect of tract length (TL) on outcomes after PNL. We performed a retrospective review of patients undergoing PNL between 2006 and 2011. Patients with preoperative computed tomography (CT), one percutaneous access tract and follow-up imaging within 3 months were included. TL was defined as distance between the skin to the calyx of puncture as measured on preoperative CT. Measurements were independently performed by two urologists and the average was used for analysis. Stone-free rate (SFR) was defined as zero fragments on follow-up imaging. Factors independently associated with the likelihood of being stone-free after PNL were determined using multivariable analysis adjusted for TL, location of access, the presence of incomplete or complete staghorn calculi and type of follow-up imaging. Complications (Clavien score) were independently assessed. A total of 222 patients were included. Median stone burden and body mass index (BMI) was 239.4 mm(2) and 30.5 [interquartile range (IQR): 25.7-36.2]. The median TL was 85.0 mm (IQR: 70.3-100.0) and highly correlated with BMI (ρ = 0.66, p PNL. PNL is a safe and effective treatment for stones in patients with differing body habitus.

  20. Test anxiety and telomere length: Academic stress in adolescents may not cause rapid telomere erosion.

    Science.gov (United States)

    Zou, Yaru; Leong, Waiian; Yao, Mingling; Hu, Xuefei; Lu, Sixiao; Zhu, Xiaowei; Chen, Lianxiang; Tong, Jianjing; Shi, Jingyi; Gilson, Eric; Ye, Jing; Lu, Yiming

    2017-02-14

    Academic stress (AS) is one of the most important health problems experienced by students, but no biomarker of the potential psychological or physical problems associated with AS has yet been identified. As several cross-sectional studies have shown that psychiatric conditions accelerate aging and shorten telomere length (TL), we explored whether AS affected TL.Between June 2014 and July 2014, we recruited 200 junior high school students with imminent final examinations for participation in this study. The students were divided into three subgroups (mild, moderate, and severe anxiety) using the Sarason Test Anxiety Scale (TAS). Saliva samples were collected for TL measurement via quantitative polymerase chain reaction (qPCR).Students from both a specialized and a general school suffered from anxiety (p > 0.05). A total 35% had severe anxiety (score: 26.09±3.87), 33% had moderate anxiety (16.98±2.64), and 32% had mild anxiety (7.89±1.92). The TAS values differed significantly (p 0.05): 1.14±0.46 for those with severe anxiety, 1.02±0.40 for those with moderate anxiety, and 1.12±0.45 for those with mild anxiety.Previous reports have found that AS is very common in Asian adolescents. We found no immediate telomere shortening in adolescents with AS. Longitudinal observations are required to determine if TL is affected by AS.

  1. Response function study of a scintillator detector of NaI(Tl); Estudo da funcao resposta de um detector cintilador de NaI(Tl)

    Energy Technology Data Exchange (ETDEWEB)

    Villa, Marcelo Barros; Costa, Alessandro Martins da, E-mail: amcosta@usp.br [Universidade de Sao Paulo (FFCLRP/USP), Ribeirao Preto, SP (Brazil). Faculdade de Filosofia, Ciencias e Letras. Dept. de Fisica

    2014-07-01

    In measurements of gamma rays with Nai (Tl) scintillator, the detectors output data are pulse height spectra, that corresponding to distorted information about the radiation source due to various errors associated with the crystal scintillation process and electronics associated, instead of power spectra photons. Pulse height spectra are related to the real power spectra by means of scintillator detector response function NaI (Tl). In this work, the response function for a cylindrical crystal of Nal (Tl) of 7,62 x 7,62 cm (diameter x length) was studied, by Monte Carlo method, using the EGSnrc tool to model the transport of radiation, combined with experimental measurements. An inverse response matrix, even with the energy of the square root, which transforms the pulse height spectrum of photon energy spectrum was obtained. The results of this transformation of pulse height spectrum for photon energy spectrum is presented, showing that the methodology employed in this study is suitable.

  2. Myocardial uptake of iodinated free fatty acids and 201Tl in experimental ischemia

    International Nuclear Information System (INIS)

    Westera, G.; Wall, E.E. van der; Visser, F.C.; Scholtalbers, A.S.; Eenige, M.J. van; Roos, J.P.

    1984-01-01

    In an experimental study, we evaluated the uptake of ( 131 I)-17-iodo heptadecanoic acid ( 131 I-HDA), ( 125 I)-15-4 (4-iodophenyl) pentadecanoic acid ( 125 I-PPA) and thallium-201 ( 201 Tl) in the dog heart. Twenty dogs were studied and divided into 3 groups: in group A, 10 dogs (4 normal, 6 with coronary artery occlusion) were studied with 131 I-HDA and 201 Tl; in group B, 5 dogs (with occlusion) received 125 I-PPA and 201 Tl; and in group C, 5 dogs (with occlusion) were studied with 125 I-PPA and 131 I-HDA. Two min after administration of the compounds the hearts were excised and stored in formaldehyde. After sectioning of the left ventricle, total uptake was counted and expressed in percentage of injected dose. Uptake in the normal myocardium (group A) was 4.2+-0.6% for 131 I-HDA and 4.6+-0.7% for 201 Tl; in the occluded dog hearts (group A) we measured values of 2.6+-0.4% for 131 I-HDA (p 201 Tl (p 131 I-HDA, 125 I-PPA and 201 Tl in groups B and C was not significantly different: group B, 125 I-PPA 2.8+-0.8% and 201 Tl 2.5+-0.5%; group C, 125 I-PPA 1.9+-0.7% and 131 I-HDA 1.6+-0.6%. Moreover, regional distribution of both iodinated fatty acids was quite comparable with the distribution of 201 Tl. We conclude that 131 I-HDA and 125 I-PPA show similar uptake as 201 Tl and are distributed according to coronary artery perfusion, which underscores their value as myocardial imaging agents. (orig.) [de

  3. Patient-Specific Instruments Based on Knee Joint Computed Tomography and Full-Length Lower Extremity Radiography in Total Knee Replacement

    Directory of Open Access Journals (Sweden)

    Hua Tian

    2018-01-01

    Conclusions: The use of PSIs based on knee joint CT and standing full-length lower extremity radiography in TKR resulted in acceptable alignment compared with the use of conventional instruments, although the marginal advantage was not statistically different. Surgical time and clinical results were also similar between the two groups. However, the PSI group had less postoperative drainage.

  4. RDM lifetime measurements in 187Tl

    International Nuclear Information System (INIS)

    Chamoli, S.K.; Joshi, P.; Kumar, A.; Govil, I.M.; Mukherjee, G.; Singh, R.P.; Muralithar, S.; Bhowmik, R.K.

    2003-01-01

    The present work is an attempt to study the shape changes in 187 Tl through a measurement of electromagnetic transition probabilities of the high spin states. The Doppler shifted recoil distance technique was used to measure the lifetimes

  5. Disquisition and technical alteration about TL apparatus

    International Nuclear Information System (INIS)

    Wang Guangxiang; Li Mingliang

    2002-01-01

    The author simply introduces the disadvantage of TL apparatus controlled by single chip. The project uses the PC computer to replace single chip control. So it must be changed the interface and made up a software with Chinese

  6. TL dosimetric properties BAM:EU

    International Nuclear Information System (INIS)

    Rao, Bellam N.; Murthy, K.V.R.; Subba Rao, B.; Saiprasad, A.S.

    2011-01-01

    In phosphor area today top priority is the replacement of the high performance but very expensive rare earth activated phosphors with cheaper materials. This essentially means replacing the rare earth ions with transition metal ions or post transition ions. Now a day's phosphors are used in various fields. After World War II, the advances in the optical spectroscopy of solids, especially those of transition metals ions help to evolve research on phosphor and solid state luminescence. In 1960 efficient rare earth activated phosphors were developed for use in color TV (Tb 3+ green, Eu 3+ red, and Dy 3+ yellow). In 1970 tricolor lamp was introduced blue emission from Ce 3+ + Tb 3+ pair was used in tricolor lamps. At present combination of halo phosphor and tri-band phosphor blend is used in many lamp as a compromise between performance, phosphor cost and the lamp making Cost. Thermo luminescence of 0.5 Gy X-ray irradiated BAM.Eu has been studied. The irradiated phosphor has been studied for its TL dosimetric properties one week after irradiation and after 100 weeks of storage. Interesting TL results are reported in the present paper. Heating rate used in the present experiment is 6.6 deg C/Sec. The following two figures are on TL recorded 100 weeks after irradiation and TL recorded after 235 weeks of storage. Before storage for 100 weeks the TL glow curve with a hump around 180 deg C followed by a peak at 273 deg C. After storage for 100 weeks the TL pattern changes entirely. i.e. the composite TL peak structure emerged as two well resolved peaks and with slightly higher TL peak temperatures at 215 deg C and 300 deg C. Normally after storage for 100 weeks the peak at 190 deg C reduces in its intensity or disappears in some cases, instead of that the peak appears at 215 deg C as well resolved peak and its intensity is almost comparable to that of 300 deg C peak. Since the TL phenomenon observed is interesting the two well resolved, isolated, high intensity peaks

  7. Progress and problems with automated TL dating

    International Nuclear Information System (INIS)

    McKerrell, H.; Mejdahl, V.

    1981-01-01

    A number of basic problems connected with the measurement of beta and gamma dose-rates are discussed, and the possibility of using low-temperature peaks in quartz and feldspar for dose-rate measurements is examined. Preliminary results of TL measurements on individual grains of quartz and feldspar are presented. A TL dating method based on the difference in the archaeological dose received by potassium feldspar and quartz grains is proposed. (author)

  8. The use of thallium diethyldithiocarbamate for mapping CNS potassium metabolism and neuronal activity: Tl+ -redistribution, Tl+ -kinetics and Tl+ -equilibrium distribution.

    Science.gov (United States)

    Wanger, Tim; Scheich, Henning; Ohl, Frank W; Goldschmidt, Jürgen

    2012-07-01

    The potassium (K(+)) analogue thallium (Tl(+)) can be used as a tracer for mapping neuronal activity. However, because of the poor blood-brain barrier (BBB) K(+) -permeability, only minute amounts of Tl(+) enter the brain after systemic injection of Tl(+) -salts like thallium acetate (TlAc). We have recently shown that it is possible to overcome this limitation by injecting animals with the lipophilic chelate complex thallium diethyldithiocarbamate (TlDDC), that crosses the BBB and releases Tl(+) prior to neuronal or glial uptake. TlDDC can thus be used for mapping CNS K(+) metabolism and neuronal activity. Here, we analyze Tl(+) -kinetics in the rodent brain both experimentally and using simple mathematical models. We systemically injected animals either with TlAc or with TlDDC. Using an autometallographic method we mapped the brain Tl(+) -distribution at various time points after injection. We show that the patterns and kinetics of Tl(+) -redistribution in the brain are essentially the same irrespective of whether animals have been injected with TlAc or TlDDC. Data from modeling and experiments indicate that transmembrane Tl(+) -fluxes in cells within the CNS in vivo equilibrate at similar rates as K(+) -fluxes in vitro. This equilibration is much faster than and largely independent of the equilibration of Tl(+) -fluxes across the BBB. The study provides further proof-of-concept for the use of TlDDC for mapping neuronal activity and CNS K(+) -metabolism. A theoretical guideline is given for the use of K(+) -analogues for imaging neuronal activity with general implications for the use of metal ions in neuroimaging. © 2012 The Authors. Journal of Neurochemistry © 2012 International Society for Neurochemistry.

  9. Degradation of myocardial perfusion SPECT images caused by contaminants in thallous (201Tl) chloride

    International Nuclear Information System (INIS)

    Staelens, Steven G.; Wit, Tim C. de; Lemahieu, Ignace A.; Beekman, Freek J.

    2008-01-01

    Thallous ( 201 Tl) chloride is a single-photon emission computed tomography (SPECT) tracer mainly used for assessing perfusion and viability of myocardial tissue. 201 Tl emits X-rays around 72 keV and gammas at 167 keV, and has a half-life of 73 h. Regulations allow an intrinsic contamination up to 3-5%, which is mainly caused by 200 Tl (368 keV; 26 h) and by 202 Tl (439 keV; 12.2 days). Contra-intuitive to the low-level percentages in which these contaminants are present, their impact may be significant because of much higher gamma camera sensitivity for these high-energy photon emissions. Therefore, we investigate the effects of the contaminants in terms of detected fractions of photons in projections and contrast degradation in reconstructed images. Acquisitions of a digital thorax phantom filled with thallous ( 201 Tl) chloride were simulated with a validated Monte Carlo tool, thereby, modelling 1% of contamination by 200 Tl and 202 Tl each. In addition, measurements of a thorax phantom on a dual-headed gamma camera were performed. The product used was contaminated by 0.17% of 200 Tl and 0.24% of 202 Tl at activity reference time (ART). This ART is specified by the manufacturer, thereby, accounting for the difference in half-lives of 201 Tl and its contaminants. These measurements were repeated at different dates associated with various contamination levels. Simulations showed that, with 1% of 200 Tl and 202 Tl, the total contamination in the 72 keV window can rise up to one out of three detected photons. For the 167keV window, the contamination is even more pronounced: more than four out of five detections in this photopeak window originate from contaminants. Measurements indicate that cold lesion contrast in myocardial perfusion SPECT imaging is at maximum close to ART. In addition to a higher noise level, relative contrast decreases 15% 2 days early to ART, which is explained by an increase in 200 Tl contamination. After ART, contrast decreased by 16% when

  10. Minimising the Spurious TL of Recently Fired Ceramics Using the Foil Technique

    International Nuclear Information System (INIS)

    Michael, C.T.; Zacharias, N.; Polikreti, K.; Pagonis, V.

    1999-01-01

    The new foil technique for measuring the natural dose in TL dating is briefly presented. In this technique very thin samples are made with the necessary plasticity to achieve the best heating contact between sample and heater plate. Measurements can then be made in vacuum and it is possible to use higher heating rates. The effect of the increase of the TL signal with the increase of the heating rate is presented. The foil technique reduces chemiluminescence and increases the TL signal. This allows the application of TL dating to be extended to lower limits (lower ages). These limits are determined by estimating quantitatively the effects of the sample preparation procedure on the induction of spurious TL (triboluminescence). Samples from a two year old ceramic vase were prepared with two different powder preparation procedures: (a) by using a hand drill with a common steel edge and (b) by crushing a piece using a vice. Measurements at a heating rate of 50 deg. C.s -1 were made. The two estimates of P (total dose) provide an estimate of age for each procedure. The age estimation for the vice prepared sample is about 30 years and for the drilled sample is higher than 120 years. It is suggested that the use of a drill for powder preparation be avoided, especially in TL dating and authenticity tests of recently fired ceramics (less than 500 years). (author)

  11. Tl response of LiF:Mg, Cu, P + PTFE to Am-Be neutrons

    International Nuclear Information System (INIS)

    Gonzalez M, P.R.

    2000-01-01

    In different laboratories of the world it is followed the research about development of new Tl materials, whose main characteristics should be their equivalence with the tissue and their high sensibility to any type of radiation. The study consists in to measure the Tl peak intensity which TLD-100 presents at being irradiated with neutrons and that appears over 250 Centigrade, for compare it with the Tl intensity of the LiF: Mg, Cu, P + PTFE dosemeters. However, not all dosemeters of the same group show the interesting peak, by this only can be the total Tl intensity of dosemeters studied. In the ININ dosemeters development laboratory, we have developed a Tl material of lithium fluoride activated with magnesium, copper and phosphorus (LiF: Mg, Cu, P) that in polycrystalline powder form is almost 35 times more sensitive than the TLD-100 commercial dosemeter of Harshaw/Filtrol, USA. With the use of polytetrafluorethylene (PTFE) and with the above described Tl material, it has been possible to obtain dosemeters in pellet form of LiF: Mg, Cu, P + PTFE. (Author)

  12. Cardiac telomere length in heart development, function, and disease.

    Science.gov (United States)

    Booth, S A; Charchar, F J

    2017-07-01

    Telomeres are repetitive nucleoprotein structures at chromosome ends, and a decrease in the number of these repeats, known as a reduction in telomere length (TL), triggers cellular senescence and apoptosis. Heart disease, the worldwide leading cause of death, often results from the loss of cardiac cells, which could be explained by decreases in TL. Due to the cell-specific regulation of TL, this review focuses on studies that have measured telomeres in heart cells and critically assesses the relationship between cardiac TL and heart function. There are several lines of evidence that have identified rapid changes in cardiac TL during the onset and progression of heart disease as well as at critical stages of development. There are also many factors, such as the loss of telomeric proteins, oxidative stress, and hypoxia, that decrease cardiac TL and heart function. In contrast, antioxidants, calorie restriction, and exercise can prevent both cardiac telomere attrition and the progression of heart disease. TL in the heart is also indicative of proliferative potential and could facilitate the identification of cells suitable for cardiac rejuvenation. Although these findings highlight the involvement of TL in heart function, there are important questions regarding the validity of animal models, as well as several confounding factors, that need to be considered when interpreting results and planning future research. With these in mind, elucidating the telomeric mechanisms involved in heart development and the transition to disease holds promise to prevent cardiac dysfunction and potentiate regeneration after injury. Copyright © 2017 the American Physiological Society.

  13. NaI(Tl) electron energy resolution

    CERN Document Server

    Mengesha, W

    2002-01-01

    NaI(Tl) electron energy resolution eta sub e was measured using the Modified Compton Coincidence Technique (MCCT). The MCCT allowed detection of nearly monoenergetic internal electrons resulting from the scattering of incident 662 keV gamma rays within a primary NaI(Tl) detector. Scattered gamma rays were detected using a secondary HPGe detector in a coincidence mode. Measurements were carried out for electron energies ranging from 16 to 438 keV, by varying the scattering angle. Measured HPGe coincidence spectra were deconvolved to determine the scattered energy spectra from the NaI(Tl) detector. Subsequently, the NaI(Tl) electron energy spectra were determined by subtracting the energy of scattered spectra from the incident source energy (662 keV). Using chi-squared minimization, iterative deconvolution of the internal electron energy spectra from the measured NaI(Tl) spectra was then used to determine eta sub e at the electron energy of interest. eta sub e values determined using this technique represent va...

  14. Mobility and lifetime of sup 2 sup 0 sup 8 Tl ions in liquid xenon

    CERN Document Server

    Walters, A J

    2003-01-01

    Positively charged sup 2 sup 0 sup 8 Tl ions are transported through liquid xenon using electric fields in the range of 4-10 kV cm sup - sup 1 and for drift distances up to 50 mm. From these measurements we deduce upper limits on the attenuation length for Tl ions in liquid xenon, resulting in a lifetime >5.5 s. In addition to these results, the field independent mobility of Tl bearing species in liquid xenon was measured to be 1.33+-0.04x10 sup - sup 4 cm sup 2 V sup - sup 1 s sup - sup 1. This result, when coupled with those for other species by previous workers, suggests that positive ion mobility in liquid xenon is proportional to the hard-core radius. Applications to Ba ion collection in a double beta decay experiment are also discussed.

  15. Response function study of a scintillator detector of NaI(Tl)

    International Nuclear Information System (INIS)

    Villa, Marcelo Barros; Costa, Alessandro Martins da

    2014-01-01

    In measurements of gamma rays with Nai (Tl) scintillator, the detectors output data are pulse height spectra, that corresponding to distorted information about the radiation source due to various errors associated with the crystal scintillation process and electronics associated, instead of power spectra photons. Pulse height spectra are related to the real power spectra by means of scintillator detector response function NaI (Tl). In this work, the response function for a cylindrical crystal of Nal (Tl) of 7,62 x 7,62 cm (diameter x length) was studied, by Monte Carlo method, using the EGSnrc tool to model the transport of radiation, combined with experimental measurements. An inverse response matrix, even with the energy of the square root, which transforms the pulse height spectrum of photon energy spectrum was obtained. The results of this transformation of pulse height spectrum for photon energy spectrum is presented, showing that the methodology employed in this study is suitable

  16. Electrochemically produced alumina as TL detector

    International Nuclear Information System (INIS)

    Osvay, M.

    1996-01-01

    The goal of this work was to compare the TL properties of various electrochemically produced alumina layers (E-AIO) in order to investigate the effect of the electrolyte and the Mg content on the alloys. It has been found that the TL sensitivity of oxidised layers is more influenced by the type of electrolyte, than by the composition of alloy. Hard oxide layer evolved in reduction electrolyte has rather different character compared to other alumina production investigated. The effect of reducing media seems to be very important during preparation of alumina layer. One of the advantages properties of E-AIO is, that it serve a promising method to increase the measuring range of TL method above 10 kGy as well. (author)

  17. Accidental and retrospective dosimetry using TL method

    International Nuclear Information System (INIS)

    Mesterházy, D.; Osvay, M.; Kovács, A.; Kelemen, A.

    2012-01-01

    Retrospective dosimetry is one of the most important tools of accidental dosimetry for dose estimation when dose measurement was not planned. In the affected area many objects can be applied as natural dosimeters. The paper discusses our recent investigations on various electronic components and common salt (NaCl) having useful thermoluminescence (TL) properties. Among materials investigated the electronic components of cell phones seem promising for retrospective dosimetry purposes, having high TL responses, proper glow curve peaks and the intensity of TL peaks vs. gamma dose received provided nearly linear response in the dose range of 10 mGy–1.5 Gy. - Highlights: ► Electronic components and common salt were investigated for accidental and retrospective dosimetry. ► SMD resistors seem promising for retrospective dosimetry purposes. ► Table salt can be used effectively for accidental dosimetry purposes, as well.

  18. Detailed α -decay study of 180Tl

    Science.gov (United States)

    Andel, B.; Andreyev, A. N.; Antalic, S.; Barzakh, A.; Bree, N.; Cocolios, T. E.; Comas, V. F.; Diriken, J.; Elseviers, J.; Fedorov, D. V.; Fedosseev, V. N.; Franchoo, S.; Ghys, L.; Heredia, J. A.; Huyse, M.; Ivanov, O.; Köster, U.; Liberati, V.; Marsh, B. A.; Nishio, K.; Page, R. D.; Patronis, N.; Seliverstov, M. D.; Tsekhanovich, I.; Van den Bergh, P.; Van De Walle, J.; Van Duppen, P.; Venhart, M.; Vermote, S.; Veselský, M.; Wagemans, C.

    2017-11-01

    A detailed α -decay spectroscopy study of 180Tl has been performed at ISOLDE (CERN). Z -selective ionization by the Resonance Ionization Laser Ion Source (RILIS) coupled to mass separation provided a high-purity beam of 180Tl. Fine-structure α decays to excited levels in the daughter 176Au were identified and an α -decay scheme of 180Tl was constructed based on an analysis of α -γ and α -γ -γ coincidences. Multipolarities of several γ -ray transitions deexciting levels in 176Au were determined. Based on the analysis of reduced α -decay widths, it was found that all α decays are hindered, which signifies a change of configuration between the parent and all daughter states.

  19. Dialysis Dependence Predicts Complications, Intensive Care Unit Care, Length of Stay, and Skilled Nursing Needs in Elective Primary Total Knee and Hip Arthroplasty.

    Science.gov (United States)

    Patterson, Joseph T; Tillinghast, Kyle; Ward, Derek

    2018-07-01

    Limited data describe risks and perioperative resource needs of total joint arthroplasty (TJA) in dialysis-dependent patients. Retrospective multiple cohort analysis of dialysis-dependent American College of Surgeons National Surgical Quality Improvement Program patients undergoing primary elective total hip and knee arthroplasty compared to non-dialysis-dependent controls from 2005 to 2015. Relative risks (RRs) of 30-day adverse events were determined by multivariate regression adjusting for baseline differences. Six hundred forty-five (0.2%) dialysis-dependent patients of 342,730 TJA patients were dialysis-dependent and more likely to be dependent, under weight, anemic, hypoalbuminemic, and have cardiopulmonary disease. In total hip arthroplasty patients, dialysis was associated with greater risk of any adverse event (RR = 1.1, P care unit (ICU) care (RR = 9.8, P total knee arthroplasty patients, dialysis conferred greater risk of any adverse event (RR = 1.1, P care (RR = 6.0, P care, longer admission, and rehabilitation needs in TJA patients. Thirty days is not sufficient to detect infectious complications among these patients. These findings inform shared decision-making, perioperative resource planning, and risk adjustment under alternative reimbursement models. Copyright © 2018 Elsevier Inc. All rights reserved.

  20. Super-ionic conductivity in (1D) nanofibrous TlGaTe2

    International Nuclear Information System (INIS)

    Sardarly, R.M.; Samedov, O.A.; Abdullaev, A.P.; Salmanov, F.T.; Urbanovic, A.; Garet, F.; Coutaz, J.-L.

    2010-01-01

    Full text : Nanodimension topologic-disorder materials constitute an important feature in the development of modern electronics. Among such materials, TlGaTe 2 is a p-type semiconductor with a nanofibrous structure Ga 3 +Te 2 - 2 groups form chains extending along the c-axis of the material. These negatively charged chains are bonded together by Tl+ ions. The resulting tetragonal lattice is characterized by a 18 D4h group symmetry. Recently, much attention has been paid to systems that behave as if they had less than 3 spatial dimensions. Such materials are often called quasi-one-dimensional (1D) nanorods, nanofibrous or nanochains. It was already studied the temperature dependence of conductivity σ (T) and current-voltage (I-V) characteristics of TlGaTe 2 . In the ohmic region of the I -V curve, σ (T) exhibits a behavior typical of hopping conductivity, which can be modeled in the framework of the Mott approximation. Moreover, it was determined the values of the density of localized states, the activation energy, the hop lengths, and the difference between the energies of states and the concentration of deep traps. The abrupt variation of the I-V curve is ascribed to the Pool-Frenkel thermal-field effect, which allows to obtain the concentration of ionized centers, the free-path lengths, the Frenkel coefficients and the shape of the potential well of TlGaTe 2 . For T>300 K, TlGaTe 2 crystals present interesting nonlinear electrical behaviors, such as switching effects and a negative-differential-resistance (NDR) region in their S-type I-V characteristics. In the NDR region, self-excited oscillations of the voltage were also observed. Here, it was investigated the temperature dependence of TlGaTe 2 crystals conductivity σ (T) in two experimental geometries, i.e. parallel and perpendicularly to the tetragonal c-axis of the crystal. The observed sharp increase of TlGaTe 2 conductivity results from a strong change of the number of the high-mobility ions. The

  1. Telomere length in children environmentally exposed to low-to-moderate levels of lead

    International Nuclear Information System (INIS)

    Pawlas, Natalia; Płachetka, Anna; Kozłowska, Agnieszka; Broberg, Karin; Kasperczyk, Sławomir

    2015-01-01

    Shorter relative telomere length in peripheral blood is a risk marker for some types of cancers and cardiovascular diseases. Several environmental hazards appear to shorten telomeres, and this shortening may predispose individuals to disease. The aim of the present cross-sectional study was to assess the effect of environmental exposure to lead on relative telomere length (rTL) in children. A cohort of 99 8-year-old children was enrolled from 2007–2010. Blood lead concentrations (B-Pb) were measured by graphite furnace atomic absorption spectrometry, and blood rTL was measured by quantitative PCR. The geometric mean of B-Pb was 3.28 μg/dl (range: 0.90–14.2), and the geometric mean of rTL was 1.08 (range: 0.49–2.09). B-Pb was significantly inversely associated with rTL in the children (r S = − 0.25, p = 0.013; in further analyses both log-transformed-univariate regression analysis β = − 0.13, p = 0.026, and R 2 adj 4%; and β = − 0.12, p = 0.056 when adjusting for mothers' smoking during pregnancy, Apgar score, mother's and father's ages at delivery, sex and mother's education, R 2 adj 12%, p = 0.011). The effect of lead remained significant in children without prenatal tobacco exposure (N = 87, r S = − 0.24, p = 0.024; in further analyses, β = − 0.13, p = 0.029, and R 2 adj 4%). rTL was not affected by sex, the concentrations of other elements in the blood (i.e., cadmium and selenium concentrations), or oxidative injury parameters (total antioxidant status, 8-hydroxydeoxyguanosine and thiobarbituric acid-reactive substances). Lead exposure in childhood appears to be associated with shorter telomeres, which might contribute to diseases, such as cardiovascular disease. The inverse association between blood lead level and the telomeres in children emphasizes the importance of further reducing lead levels in the environment. - Highlights: • This cross-sectional study analyzes the association between environmental lead exposure

  2. Telomere length in children environmentally exposed to low-to-moderate levels of lead

    Energy Technology Data Exchange (ETDEWEB)

    Pawlas, Natalia, E-mail: n-pawlas@wp.pl [Institute of Occupational Medicine and Environmental Health, PL 41-200 Sosnowiec (Poland); Płachetka, Anna [Department of Animal Physiology and Ecotoxicology, University of Silesia, Bankowa str. 9, 40-007 Katowice (Poland); Kozłowska, Agnieszka [Institute of Occupational Medicine and Environmental Health, PL 41-200 Sosnowiec (Poland); Broberg, Karin [Institute of Environmental Medicine, Unit of Metals & Health, Box 210, SE-171 77 Stockholm (Sweden); Kasperczyk, Sławomir [Department of Biochemistry, Medical University of Silesia, Katowice, SMDZ in Zabrze, 41-808 Zabrze (Poland)

    2015-09-01

    Shorter relative telomere length in peripheral blood is a risk marker for some types of cancers and cardiovascular diseases. Several environmental hazards appear to shorten telomeres, and this shortening may predispose individuals to disease. The aim of the present cross-sectional study was to assess the effect of environmental exposure to lead on relative telomere length (rTL) in children. A cohort of 99 8-year-old children was enrolled from 2007–2010. Blood lead concentrations (B-Pb) were measured by graphite furnace atomic absorption spectrometry, and blood rTL was measured by quantitative PCR. The geometric mean of B-Pb was 3.28 μg/dl (range: 0.90–14.2), and the geometric mean of rTL was 1.08 (range: 0.49–2.09). B-Pb was significantly inversely associated with rTL in the children (r{sub S} = − 0.25, p = 0.013; in further analyses both log-transformed-univariate regression analysis β = − 0.13, p = 0.026, and R{sup 2}adj 4%; and β = − 0.12, p = 0.056 when adjusting for mothers' smoking during pregnancy, Apgar score, mother's and father's ages at delivery, sex and mother's education, R{sup 2}adj 12%, p = 0.011). The effect of lead remained significant in children without prenatal tobacco exposure (N = 87, r{sub S} = − 0.24, p = 0.024; in further analyses, β = − 0.13, p = 0.029, and R{sup 2}adj 4%). rTL was not affected by sex, the concentrations of other elements in the blood (i.e., cadmium and selenium concentrations), or oxidative injury parameters (total antioxidant status, 8-hydroxydeoxyguanosine and thiobarbituric acid-reactive substances). Lead exposure in childhood appears to be associated with shorter telomeres, which might contribute to diseases, such as cardiovascular disease. The inverse association between blood lead level and the telomeres in children emphasizes the importance of further reducing lead levels in the environment. - Highlights: • This cross-sectional study analyzes the association between

  3. Isotopic exchange in a neutron-irradiated mixed-valence compound: Tl3(I) Tl(III)Cl6

    International Nuclear Information System (INIS)

    Fernandez Valverde, S.; Duplatre, G.

    1977-01-01

    The initial distribution of Tl(I) and Tl(III) species, and its change on heating, have been investigated in solid thermal neutron-irradiated Th 4 Cl 6 . An initial ratio of 5/1 for 204 Tl(I)/ 204 Tl(III) is found and this remains constant for integral gamma-doses of 3 to 12 MRad. The variation of the 204 Tl(III) fraction with temperature is found identical to that observed in labelled Tl 4 Cl 6 for which a genuine isotopic exchange has previously been described. It is concluded that the recoil species are rapidly converted, after the recoil processes, into stable ions

  4. Telomere length of circulating leukocyte subpopulations and buccal cells in patients with ischemic heart failure and their offspring.

    Directory of Open Access Journals (Sweden)

    Liza S M Wong

    Full Text Available BACKGROUND: We aimed to find support for the hypothesis that telomere length (TL is causally involved in the pathogenesis of ischemic heart failure (IHF. We measured TL in IHF patients and their high-risk offspring and determined whether mean leukocyte TL reflects TL in CD34+ progenitor. We additionally measured TL of offspring of patients and controls to examine heritability throughout different cell types. METHODS AND RESULTS: TL was measured by qPCR in overall leukocytes, CD34+ progenitor cells, mononuclear cells (MNCs, and buccal cells in 27 IHF patients, 24 healthy controls and 60 offspring. TL in IHF patients was shorter than healthy controls in leukocytes (p = 0.002, but not in CD34+ cells (p = 0.39, MNCs (p = 0.31 or buccal cells (p = 0.19. Offspring of IHF patients had shorter TL in leukocytes than offspring of healthy subjects (p = 0.04 but not in other cell types. Controls and offspring showed a good within person correlation between leukocytes and CD34+ cells (r 0.562; p = 0.004 and r 0.602; p = 0.001, respectively. In IHF patients and offspring the correlation among cell types was blunted. Finally, we found strong correlations between parent and offspring TL in all four cell types. CONCLUSIONS: Reduced leukocyte TL in offspring of IHF subjects suggests a potential causal link of TL in ischemic heart disease. However, this causality is unlikely to originate from exhaustion of TL in CD34+ progenitor or MNC cells as their lengths are not well captured by overall leukocyte TL. Additionally, we found strong correlations between parent and offspring TL in all examined cell types, suggesting high heritability of TL among cell types.

  5. Short telomere length is associated with impaired cognitive performance in European ancestry cohorts

    NARCIS (Netherlands)

    Hägg, S.; Zhan, Y.; Karlsson, Robert; Gerritsen, L.; Ploner, A.; Lee, J.S.; Broer, L.; Deelen, J.; Marioni, R.E.; Wong, A.|info:eu-repo/dai/nl/29867291X; Lundquist, A.; Zhu, G.; Hansell, N.K.; Sillanpää, E.; Fedko, I O; Amin, N.A.; Beekman, Jeffrey M.; de Craen, A.J.M.; Degerman, S.; Harris, S.E.; Kan, K.-J.; Martin-Ruiz, C.M.; Montgomery, Grant W.; Adolfsson, A.N.; Reynolds, Chandra A.; Samani, Nilesh J; Suchiman, H.E.D.; Viljanen, A.; Von Zglinicki, T.; Wright, M J; Hottenga, J.J.; Boomsma, Dorret I; Rantanen, T.; Kaprio, J.A.; Nyholt, D.R.; Martin, N.G.|info:eu-repo/dai/nl/314123083; Nyberg, Lars; Adolfsson, R.; Kuh, D.; Starr, John M; Deary, Ian J; Slagboom, P Eline; Van Duijn, C.M.|info:eu-repo/dai/nl/068368232; Codd, V.; Pedersen, Nancy L.

    2017-01-01

    The association between telomere length (TL) dynamics on cognitive performance over the life-course is not well understood. This study meta-analyses observational and causal associations between TL and six cognitive traits, with stratifications on APOE genotype, in a Mendelian Randomization (MR)

  6. Cation composition and oxygen content dependence of crystal structure and T sub c for Tl sub 2 sub - sub x Ba sub 2 Ca sub 2 Cu sub 3 sub + sub z O sub y

    CERN Document Server

    Idemoto, Y; Koura, N; Kamiyama, T; Oikawa, K; Izumi, F

    2003-01-01

    Tl sub 2 sub - sub x Ba sub 2 Ca sub 2 Cu sub 3 sub + sub z O sub y (Tl-2223 system) superconducting oxides with various Tl contents and Cu contents were prepared. We investigated the relation between crystal structure and superconducting property dependence of Tl and Cu content. First, we obtained an almost single-phase material at a Tl content 2-x = 1.7 and the Tl-2223 phase remained the main phase in the region of 2 - x >= 0.631 of Tl sub 2 sub - sub x Ba sub 2 Ca sub 2 Cu sub 3 O sub y. T sub c was about 120 K for the Tl-2223 in a wide range of 0.631 <= 2 - x <= 1.761. Second, we obtained a single-phase at 2 - x = 1.777 and Cu content 3 + z = 3.284 of Tl sub 2 sub - sub x Ba sub 2 Ca sub 2 Cu sub 3 sub + sub z O sub y. The T sub c (zero) dependence of Cu/Tl ratio, showed a maximum value of 122 K at Cu/Tl ratio = 2.026. Based on results of crystal structure refinements by powder neutron diffraction, it was found that the change in bond length and angle dependence of average Cu valence were similar fo...

  7. Dipole response of the odd-proton nucleus 205Tl up to the neutron-separation energy

    Science.gov (United States)

    Benouaret, N.; Beller, J.; Pai, H.; Pietralla, N.; Ponomarev, V. Yu; Romig, C.; Schnorrenberger, L.; Zweidinger, M.; Scheck, M.; Isaak, J.; Savran, D.; Sonnabend, K.; Raut, R.; Rusev, G.; Tonchev, A. P.; Tornow, W.; Weller, H. R.; Kelley, J. H.

    2016-11-01

    The low-lying electromagnetic dipole strength of the odd-proton nuclide 205Tl has been investigated up to the neutron separation energy exploiting the method of nuclear resonance fluorescence. In total, 61 levels of 205Tl have been identified. The measured strength distribution of 205Tl is discussed and compared to those of even-even and even-odd mass nuclei in the same mass region as well as to calculations that have been performed within the quasi-particle phonon model.

  8. Dipole response of the odd-proton nucleus 205Tl up to the neutron-separation energy

    International Nuclear Information System (INIS)

    Benouaret, N; Beller, J; Pai, H; Pietralla, N; Ponomarev, V Yu; Romig, C; Schnorrenberger, L; Zweidinger, M; Scheck, M; Isaak, J; Savran, D; Sonnabend, K; Raut, R; Rusev, G; Tonchev, A P; Tornow, W; Weller, H R; Kelley, J H

    2016-01-01

    The low-lying electromagnetic dipole strength of the odd-proton nuclide 205 Tl has been investigated up to the neutron separation energy exploiting the method of nuclear resonance fluorescence. In total, 61 levels of 205 Tl have been identified. The measured strength distribution of 205 Tl is discussed and compared to those of even–even and even–odd mass nuclei in the same mass region as well as to calculations that have been performed within the quasi-particle phonon model. (paper)

  9. Thallium speciation in plant tissues-Tl(III) found in Sinapis alba L. grown in soil polluted with tailing sediment containing thallium minerals.

    Science.gov (United States)

    Krasnodębska-Ostręga, Beata; Sadowska, Monika; Ostrowska, Sylwia

    2012-05-15

    Besides the dominant species in plants-Tl(I), noticeable amounts of Tl(III) (about 10% of total Tl content) were found in extracts of plants cultivated in the presence of tailing sediments, which are the main source of anthropogenic thallium already present in the environment. It is an important step of gaining knowledge about the detoxification mechanisms developed by Sinapis alba. This plant species is highly tolerant to Tl and it is able to cumulate high amounts of Tl and transport it into the above-ground organs. For more adequate estimation of accumulating abilities of S. alba, the elements' bioavailability was taken into consideration. The obtained bioconcentration factors of Cd (AF=0.6) and Zn (AF=1-2) were significantly lower than of Tl (AF=100-200). The biomass production was similar to the biomass of control cultivation. The results were based on ICP MS measurements of total elements' content and HPLC ICP MS for speciation analysis. The quality of obtained results was evaluated based on the intermethod comparison with voltammetry as a reference method. Comparison of data obtained using ICP MS and electrochemical methods (after a proper chemical treatment) was also used for indication of Tl(III) presence and for proving that Tl(I) was not transferred into Tl(III) during analytical procedures. Copyright © 2012 Elsevier B.V. All rights reserved.

  10. Brain SPECT with Tl-201 DDC

    International Nuclear Information System (INIS)

    Bruine, J.F. de.

    1988-01-01

    The development, animal and human experiments and the first clinical results of a new blood flow tracer thallium-201 diethyldithiocarbamate (Tl-201 DDC) are discussed for functional brain imaging with single-photon emission computed tomography (SPECT). 325 refs.; 43 figs.; 22 tabs

  11. (Tl, Sb) and (Tl, Bi) binary surface reconstructions on Ge(111) substrate

    Science.gov (United States)

    Gruznev, D. V.; Bondarenko, L. V.; Tupchaya, A. Y.; Yakovlev, A. A.; Mihalyuk, A. N.; Zotov, A. V.; Saranin, A. A.

    2018-03-01

    2D compounds made of Group-III and Group-V elements on the surface of silicon and germanium attract considerable attention due to prospects of creating III-V binary monolayers, which are predicted to hold advanced physical properties. In the present work, we have investigated two such systems, (Tl, Sb)/Ge(111) and (Tl, Bi)/Ge(111) using scanning tunneling microscopy, low energy electron diffraction observations and density-functional-theory calculations. In addition to the previously reported surface structures of 2D (Tl, Sb) and (Tl, Bi) compounds on Si(111), we found new ones, namely, √{ 7} × √{ 7} and 3 × 3. Formation processes and plausible models of their atomic arrangements are discussed.

  12. Optimising multi-product multi-chance-constraint inventory control system with stochastic period lengths and total discount under fuzzy purchasing price and holding costs

    Science.gov (United States)

    Allah Taleizadeh, Ata; Niaki, Seyed Taghi Akhavan; Aryanezhad, Mir-Bahador

    2010-10-01

    While the usual assumptions in multi-periodic inventory control problems are that the orders are placed at the beginning of each period (periodic review) or depending on the inventory level they can happen at any time (continuous review), in this article, we relax these assumptions and assume that the periods between two replenishments of the products are independent and identically distributed random variables. Furthermore, assuming that the purchasing price are triangular fuzzy variables, the quantities of the orders are of integer-type and that there are space and service level constraints, total discount are considered to purchase products and a combination of back-order and lost-sales are taken into account for the shortages. We show that the model of this problem is a fuzzy mixed-integer nonlinear programming type and in order to solve it, a hybrid meta-heuristic intelligent algorithm is proposed. At the end, a numerical example is given to demonstrate the applicability of the proposed methodology and to compare its performance with one of the existing algorithms in real world inventory control problems.

  13. Quantitative evaluation of right ventricular overload in cor pulmonale using sup 201 Tl myocardial SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Kato, Hiroshi; Misawa, Toshihiro; Kutsumi, Yasunori [Fukui Medical School, Matsuoka (Japan); and others

    1991-01-01

    To determine quantitatively the discriminant and characteristics of cor pulmonale, {sup 201}Tl myocardial perfusion SPECT was performed in 16 patients with chronic obstructive pulmonary disease (COPD) and 7 with restrictive pulmonary disease (RPD). One section of the short-axis SPECT image in which the right ventricle was most clearly visualized was selected. Tl-score was defined as the ratio of the sum of counts in the region of interest (ROI) at the anterior, mid, and posterior regions of the right ventricular free wall to the sum of counts in ROI at the posterior, lateral, and anterior walls of the left ventricle, and the anterior and posterior regions of the interventricular septum. In the group of COPD patients, Tl-score was positively correlated with mean pulmonary arterial pressure (mPAP), total pulmonary vascular resistance (TPR), and arterial carbon dioxide tension (PaCO{sub 2}), while it was inversely correlated with arterial oxygen tension (PaO{sub 2}). However, there was no significant correlation between Tl-score and mPAP, TPR, PaCO{sub 2}, and PaO{sub 2} in the group of RPD patients. In assessing pulmonary hypertension as defined by mPAP over 20 mmHg, a Tl-score greater than 0.25 was useful with a sensitivity of 69% and a specificity of 90%. The occurrence of cor pulmonale is a major factor in determining the prognosis of COPD patients. It was concluded that {sup 201}Tl myocardial SPECT is useful for evaluating right ventricular overload quantitatively, as well as for assessing core pulmonale, especially in COPD patients, since the ratio of Tl counts in the right and left ventricles was significantly correlated with right cardiopulmonary hemodynamic parameters. (N.K.).

  14. Quantitative evaluation of right ventricular overload in cor pulmonale using 201Tl myocardial SPECT

    International Nuclear Information System (INIS)

    Kato, Hiroshi; Misawa, Toshihiro; Kutsumi, Yasunori

    1991-01-01

    To determine quantitatively the discriminant and characteristics of cor pulmonale, 201 Tl myocardial perfusion SPECT was performed in 16 patients with chronic obstructive pulmonary disease (COPD) and 7 with restrictive pulmonary disease (RPD). One section of the short-axis SPECT image in which the right ventricle was most clearly visualized was selected. Tl-score was defined as the ratio of the sum of counts in the region of interest (ROI) at the anterior, mid, and posterior regions of the right ventricular free wall to the sum of counts in ROI at the posterior, lateral, and anterior walls of the left ventricle, and the anterior and posterior regions of the interventricular septum. In the group of COPD patients, Tl-score was positively correlated with mean pulmonary arterial pressure (mPAP), total pulmonary vascular resistance (TPR), and arterial carbon dioxide tension (PaCO 2 ), while it was inversely correlated with arterial oxygen tension (PaO 2 ). However, there was no significant correlation between Tl-score and mPAP, TPR, PaCO 2 , and PaO 2 in the group of RPD patients. In assessing pulmonary hypertension as defined by mPAP over 20 mmHg, a Tl-score greater than 0.25 was useful with a sensitivity of 69% and a specificity of 90%. The occurrence of cor pulmonale is a major factor in determining the prognosis of COPD patients. It was concluded that 201 Tl myocardial SPECT is useful for evaluating right ventricular overload quantitatively, as well as for assessing core pulmonale, especially in COPD patients, since the ratio of Tl counts in the right and left ventricles was significantly correlated with right cardiopulmonary hemodynamic parameters. (N.K.)

  15. Principles of Good Practice in SoTL

    Science.gov (United States)

    Felten, Peter

    2013-01-01

    For the Scholarship of Teaching and Learning (SoTL) to be understood as significant intellectual work in the academy, SoTL practitioners need to identify shared principles of good practice. While honoring the diversity of SoTL in its many forms across the globe, such principles can serve as a heuristic for assessing work in our field. These…

  16. Setting the trajectory: racial disparities in newborn telomere length.

    Science.gov (United States)

    Drury, Stacy S; Esteves, Kyle; Hatch, Virginia; Woodbury, Margaret; Borne, Sophie; Adamski, Alys; Theall, Katherine P

    2015-05-01

    To explore racial differences in newborn telomere length (TL) and the effect moderation of the sex of the infant while establishing the methodology for the use of newborn blood spots for TL analyses. Pregnant mothers were recruited from the Greater New Orleans area. TL was determined via monochrome multiplex quantitative real-time polymerase chain reaction on DNA extracted from infant blood spots. Demographic data and other covariates were obtained via maternal report before the infant's birth. Birth outcome data were obtained from medical records and maternal report. Black infants weighed significantly less than white infants at birth and had significantly longer TL than white infants (P=.0134), with the strongest effect observed in black female infants. No significant differences in gestational age were present. Significant racial differences in TL were present at birth in this sample, even after we controlled for a range of birth outcomes and demographic factors. Because longer initial TL is predictive of more rapid TL attrition across the life course, these findings provide evidence that, even at birth, biological vulnerability to early life stress may differ by race and sex. Copyright © 2015 Elsevier Inc. All rights reserved.

  17. Fundamental length and relativistic length

    International Nuclear Information System (INIS)

    Strel'tsov, V.N.

    1988-01-01

    It si noted that the introduction of fundamental length contradicts the conventional representations concerning the contraction of the longitudinal size of fast-moving objects. The use of the concept of relativistic length and the following ''elongation formula'' permits one to solve this problem

  18. Activation analysis of thallium in urine using the 203Tl(n,2n) 202Tl reaction

    International Nuclear Information System (INIS)

    Korob, R.O.; Cohen, I.M.; Lage, M.; Baro, G.B.

    1976-04-01

    The method developed by the authors of thallium determination in human urine, based on the 203 Tl(n,2n) 202 Tl reaction followed by chemical separation and measurement of the produced 202 Tl by gamma spectrometry, is described. Its application in some cases of intoxication by thallium is reported. The advantages and limitations of the described technique are discussed. (author) [es

  19. Flame Length

    Data.gov (United States)

    Earth Data Analysis Center, University of New Mexico — Flame length was modeled using FlamMap, an interagency fire behavior mapping and analysis program that computes potential fire behavior characteristics. The tool...

  20. Stability of Tl-Ba-Ca-Cu-O superconducting thin films

    Energy Technology Data Exchange (ETDEWEB)

    Siegal, M. P. [Sandia National Laboratories, Albuquerque, New Mexico 87185-1421 (United States); Overmyer, D. L. [Sandia National Laboratories, Albuquerque, New Mexico 87185-1421 (United States); Venturini, E. L. [Sandia National Laboratories, Albuquerque, New Mexico 87185-1421 (United States); Padilla, R. R. [Sandia National Laboratories, Albuquerque, New Mexico 87185-1421 (United States); Provencio, P. N. [Sandia National Laboratories, Albuquerque, New Mexico 87185-1421 (United States)

    1999-12-01

    We report the stability of TlBa{sub 2}CaCu{sub 2}O{sub 7} and Tl{sub 2}Ba{sub 2}CaCu{sub 2}O{sub 8} on LaAlO{sub 3}(100) epitaxial thin films, under a variety of conditions. All films are stable in acetone and methanol and with repeated thermal cycling to cryogenic temperatures. Moisture, especially vapor, degrades film quality rapidly. These materials are stable to high temperatures in either N{sub 2} or O{sub 2} ambients. While total degradation, resulting from Tl depletion, occurs at the same temperatures for both phases, 600 degree sign C in N{sub 2} and 700 degree sign C in O{sub 2}, the onset of degradation occurs at somewhat lower temperatures for TlBa{sub 2}CaCu{sub 2}O{sub 7} than for Tl{sub 2}Ba{sub 2}CaCu{sub 2}O{sub 8}. (c) 1999 Materials Research Society.

  1. Setting the Trajectory: Racial Disparities in Newborn Telomere Length

    Science.gov (United States)

    Drury, Stacy S.; Esteves, Kyle; Hatch, Virginia; Woodbury, Margaret; Borne, Sophie; Adamski, Alys; Theall, Katherine P.

    2015-01-01

    Objective To explore racial differences in newborn telomere length (TL) and the effect moderation of the sex of the infant while establishing the methodology for the use of newborn blood spots for telomere length analyses. Study design Pregnant mothers were recruited from the Greater New Orleans area. TL was determined using MMQ-PCR on DNA extracted from infant blood spots. Demographic data and other covariates were obtained via maternal report prior to infant birth. Birth outcome data were obtained from medical records and maternal report. Results Black infants weighed significantly less than white infants at birth, and had significantly longer TL than White infants (p=0.0134), with the strongest effect observed in Black female infants. No significant differences in gestational age were present. Conclusions Significant racial differences in TL were present at birth in this sample, even after controlling for a range of birth outcomes and demographic factors. As longer initial TL is predictive of more rapid TL attrition across the life course, these findings provide evidence that, even at birth, biological vulnerability to early life stress may differ by race and sex. PMID:25681203

  2. Length correction for early-juvenile Brazilian herring Sardinella janeiro (Eigenmann, 1894 after preservation in formalin, ethanol and freezing

    Directory of Open Access Journals (Sweden)

    Joaquim N. S. Santos

    Full Text Available This work aims to quantify the variation in total length and body mass for the early-juvenile Brazilian herring Sardinella janeiro and to determine total length and body mass correction equation to allow fresh measures to be calculated from preserved ones. Fishes were randomly assigned to one of five preservation methods (freezing at - 20º C, 2.5% and 5% formalin, 70% and 95% ethanol, and measured for total length (TL and body mass (W before preservation, and on days 5, 15, 30, and 60 after storage. Significant reductions in total length and body mass occurred during the first 5 days after preservation and continued to contract significantly at a lesser rate through 30 days in most methods. Exceptions were shown for body mass in freezing and 5% formalin, where the greatest losses occurred after 30 days of preservation. The degree of shrinkage for total length and body mass was very much dependent on fish size, with smaller specimens shrinking more than larger ones. The fresh total length and body mass can be back-calculated using equations that describe the relationship between fresh and preserved individuals after 60 days storage for all methods except for body mass in freezing.

  3. Microcomputer control of automated TL reader

    International Nuclear Information System (INIS)

    Bjarland, B.

    1980-01-01

    An automatic TL reader has been developed for use within a TLD based personal monitoring service. A 6800 based microcomputer is used for system control, operator communication, calibration and checking of reader operation, and for output of data. The dosimeter identity code is printed in human readable characters on the dosimeter card, and is read by using an optical character recognition unit. The code may include individual sensitivity correction coefficients for the TL chips on the card. The chips are heated with hot nitrogen gas and the thermoluminescence is recorded by a photomultiplier tube circuit, the gain and offset of which are continuously monitored and, when necessary, adjusted, to maintain calibration. The reader may operate in any of seven modes, i.e. reading modes for three types of dosimeters, semiautomatic modes for production of the three types of dosimeters, and a monitor mode. (Auth.)

  4. Tl and OSL on diopside crystal

    International Nuclear Information System (INIS)

    Cano, N.F.; Watanabe, S.; Mittani, J.C.R.; Yukihara, E.G.

    2006-01-01

    The diopside with chemical composition CaMgSi 2 O 6 is part of an important solid solution series of the pyroxene group. The mineral is commonly found in meteorites and it is an important rock forming mineral of medium and high grade metamorphic rocks which are rich in calcium. In the bibliography it is possible to found several studies on electron spin resonance (ESR), reflectance, etc. but not on thermoluminescence (TL) or optically stimulated luminescence (OSL). In the present work we studied diopside TL and OSL behaviour on natural and natural irradiated samples. The sample used in our study is a white coloured diopside provided by Mineracao Sao Judas located in Sao Paulo, Brazil. The X-Ray Fluorescence technique has shown high concentrations of SiO 2 (55.81 % mol), CaO (23.47 % mol), MgO (18.03 % mol), Al 2 O 3 (1.56 % mol), Fe 2 O 3 (0.53 % mol), K 2 O (0.44 % mol), TiO 2 (0.065 % mol), P 2 O 5 (0.026 % mol), and MnO (0.013 % mol). TL measurements on natural samples show four TL peaks at 160, 260, 360, and 450 C. After beta-irradiation an increment mainly in the low temperature peaks is observed. As for OSL measurements, low OSL signal was observed on natural samples using blue light stimulation and UV detection. The intensity of the signal was observed to increase with the irradiation dose. (Author)

  5. Measurement of conversion coefficients in 208Tl

    International Nuclear Information System (INIS)

    Wendling, F.

    1976-06-01

    A electron spectrometer composed by a Li drifted Si detector and a uniform magnetic field was constructed. The magnetic field is used to focus the electrons on the detector and to filter the other radiations. After the construction the instrument was calibrated in absolute eficience and was used together with a Ge(Li) spectrometer also calibrated, in the measurement of internal conversion coeficients of the 433 and 453 keV transitions in 208 Tl [pt

  6. Improving TL dosimetry for external radiotherapy

    International Nuclear Information System (INIS)

    Bustos, S.R.; Velez, G.; Rubio, M.

    1998-01-01

    Full text: In vivo thermoluminescence dosimetry (TLD) has always been one of the most accurate dosimetry method for external radiotherapy control, but the delay in the response is a well know drawback when it is applied. In this work we show some improvements and demonstrate that keeping the precision and accuracy of this technique, it is possible to obtain a response in few hours. Harshaw 4000 TL reader and LiF TLD-100 dosimeters, chips (3,1 x 3,1 x 0,9 mm 3 ) and rods (1 x 1 x 6 mm 3 ) have been used. The thermal treatment necessary to reuse the TLD is only 1h at 400 degree C, by using a glow curve analyser developed at the Ciemat (Spain), that allows a complete, prompt and precise identification of the individuals peaks. The dosimeters are periodically and individually calibrated. We also have study the factors contributing to the relation TL-dose like linearity, energy correction, directional response and fading. All those results are included into an Excel worksheet which automatically give us the dose resulting from the TL reading (peaks areas 4 and 5). The obtained uncertainty is better than 5%. The TLD already irradiated in radiotherapy institutions distant 30-40 Km from our centre can be read and analysed in about 3-4 hours. These facts render our methods rapid and allow a better control of radiotherapy treatment even if it is bi-fractionated. (author) [es

  7. Evaluation of Tl-201 SPECT imaging findings in prostate cancer

    Directory of Open Access Journals (Sweden)

    Sinem Ozyurt

    2015-07-01

    Full Text Available Objectives: To compare with histopathological findings the findings of prostate cancer imaging by SPECT method using Tl-201 as a tumor seeking agent. Methods: The study comprised 59 patients (age range 51-79 years, mean age 65.3 ± 6.8 years who were planned to have transrectal ultrasonography (TRUS-guided biopsies due to suspicion of prostate cancer between April 2011 and September 2011. Early planar, late planar and SPECT images were obtained for all patients. Scintigraphic evaluation was made in relation to uptake presence and patterns in the visual assessment and to Tumor/Background (T/Bg ratios for both planar and SPECT images in the quantitative assessment. Histopathological findings were compatible with benign etiology in 36 (61% patients and malign etiology in 23 (39% patients. Additionally, comparisons were made to evaluate the relationships between uptake patterns,total PSA values and Gleason scores. Results: A statistically significant difference was found between the benign and malignant groups in terms of uptake in planar and SPECT images and T/Bg ratios and PSA values. No statistically significant difference was found between uptake patterns of planar and SPECT images and Gleason scores in the malignant group. Conclusions: SPECT images were superior to planar images in the comparative assessment. Tl-201 SPECT imaging can provide an additional contribution to clinical practice in the diagnosis of prostate cancer and it can be used in selected patients.

  8. Thallium (Tl) sorption onto illite and smectite: Implications for Tl mobility in the environment

    Science.gov (United States)

    Martin, Loïc A.; Wissocq, Aubéry; Benedetti, M. F.; Latrille, Christelle

    2018-06-01

    Clay minerals play a relevant role in the transport and fate of trace elements in the environment. Though illite has been referred as an important Thallium (Tl) bearing phase in soils, mechanisms and affinity of thallium for clay minerals remain poorly known. This study investigated the sorption behavior of thallium as Tl(I) onto illite and smectite, two clay minerals occurring mainly in soils and sediments. Different sorption experiments were carried out under various pH conditions and Tl concentrations, in competition with sodium and calcium at a constant ionic strength of 0.01 mol L-1. Our results showed that illite displayed more affinity than smectite for thallium. With illite, the distribution coefficients (Kd in L kg-1) varied between 102.75 ± 0.17 and 104.0 ± 0.17 in Na solutions versus between 102.25 ± 0.17 and 103.0 ± 0.17 in Ca solutions, depending on pH. With smectite, Kd (in L kg-1) ranged between 102.50 ± 0.16 and 103.20 ± 0.16 and between 101.25 ± 0.16 and 101.95 ± 0.16 in Na and Ca solutions, respectively. Sorption behavior was described with the Multi-Site Ion Exchanger model and selectivity coefficients with respect to protons were calculated for the first time. In all cases, independently of clay mineral and background electrolyte, low capacity but highly reactive sites were dominant in thallium uptake, highlighting Tl affinity for those sites. Moreover, the exchangeable and reversible interactions between Tl+ and clays reactive sites suggested that in changing conditions, thallium could be released in solution. The role of clay minerals in thallium environmental cycle is evident and confirmed illite to be a dominant Tl bearing phase, in some environment competing with manganese oxides. Compared to others Tl bearing mineral phases, clays are ranked as follows: MnO2 > illite > smectite ∼ ferrihydrite ≥ Al2O3 ∼ goethite > SiO2. Finally, over the three monovalent cations (Tl, Rb, Cs) Tl is the one less sorbed on illite independently of

  9. Positive Selection of γδ CTL by TL Antigen Expressed in the Thymus

    Science.gov (United States)

    Tsujimura, Kunio; Takahashi, Toshitada; Morita, Akimichi; Hasegawa-Nishiwaki, Hitomi; Iwase, Shigeru; Obata, Yuichi

    1996-01-01

    To elucidate the function of the mouse TL antigen in the thymus, we have derived two TL transgenic mouse strains by introducing Tla a -3 of A strain origin with its own promoter onto a C3H background with no expression of TL in the thymus. These transgenic mouse strains, both of which express high levels of Tlaa-3-TL antigen in their thymus, were analyzed for their T cell function with emphasis on cytotoxic T lymphocyte (CTL) generation. A T cell response against TL was induced in Tg.Tlaa-3-1, Tg.Tlaa-3-2, and control C3H mice by skin grafts from H-2K b/T3 b transgenic mice, Tg.Con.3-1, expressing T3b-TL ubiquitously. Spleen cells from mice that had rejected the T3b-TL positive skin grafts were restimulated in vitro with Tg.Con.3-1 irradiated spleen cells. In mixed lymphocyte cultures (MLC), approximately 20% and 15% of Thy-1+ T cells derived from Tg.Tlaa-3-1 and Tg.Tlaa-3-2, respectively, expressed TCRγδ, whereas almost all those from C3H expressed TCRαβ. The MLC from Tg.Tlaa-3-2 and C3H demonstrated high CTL activity against TL, while those from Tg.Tlaa-3-1 had little or none. The generation of γδ CTL recognizing TL in Tg.Tlaa-3-2, but not C3H mice, was confirmed by the establishment of CTL clones. A total of 14 γδ CTL clones were established from Tg.Tlaa-3-2, whereas none were obtained from C3H. Of the 14 γδ CTL clones, 8 were CD8+ and 6 were CD4−CD8− double negative. The CTL activity of all these clones was TL specific and inhibited by anti-TL, but not by anti-H-2 antibodies, demonstrating that they recognize TL directly without antigen presentation by H-2. The CTL activity was blocked by antibodies to TCRγδ and CD3, and also by antibodies to CD8α and CD8β in CD8+ clones, showing that the activity was mediated by TCRγδ and coreceptors. The thymic origin of these γδ CTL clones was indicated by the expression of Thy-1 and Ly-1 (CD5), and also CD8αβ heterodimers in CD8+ clones on their surfaces and by the usage of TCR Vγ4 chains in 12 of

  10. Fundamental length

    International Nuclear Information System (INIS)

    Pradhan, T.

    1975-01-01

    The concept of fundamental length was first put forward by Heisenberg from purely dimensional reasons. From a study of the observed masses of the elementary particles known at that time, it is sumrised that this length should be of the order of magnitude 1 approximately 10 -13 cm. It was Heisenberg's belief that introduction of such a fundamental length would eliminate the divergence difficulties from relativistic quantum field theory by cutting off the high energy regions of the 'proper fields'. Since the divergence difficulties arise primarily due to infinite number of degrees of freedom, one simple remedy would be the introduction of a principle that limits these degrees of freedom by removing the effectiveness of the waves with a frequency exceeding a certain limit without destroying the relativistic invariance of the theory. The principle can be stated as follows: It is in principle impossible to invent an experiment of any kind that will permit a distintion between the positions of two particles at rest, the distance between which is below a certain limit. A more elegant way of introducing fundamental length into quantum theory is through commutation relations between two position operators. In quantum field theory such as quantum electrodynamics, it can be introduced through the commutation relation between two interpolating photon fields (vector potentials). (K.B.)

  11. FTO associations with obesity and telomere length.

    Science.gov (United States)

    Zhou, Yuling; Hambly, Brett D; McLachlan, Craig S

    2017-09-01

    This review examines the biology of the Fat mass- and obesity-associated gene (FTO), and the implications of genetic association of FTO SNPs with obesity and genetic aging. Notably, we focus on the role of FTO in the regulation of methylation status as possible regulators of weight gain and genetic aging. We present a theoretical review of the FTO gene with a particular emphasis on associations with UCP2, AMPK, RBL2, IRX3, CUX1, mTORC1 and hormones involved in hunger regulation. These associations are important for dietary behavior regulation and cellular nutrient sensing via amino acids. We suggest that these pathways may also influence telomere regulation. Telomere length (TL) attrition may be influenced by obesity-related inflammation and oxidative stress, and FTO gene-involved pathways. There is additional emerging evidence to suggest that telomere length and obesity are bi-directionally associated. However, the role of obesity risk-related genotypes and associations with TL are not well understood. The FTO gene may influence pathways implicated in regulation of TL, which could help to explain some of the non-consistent relationship between weight phenotype and telomere length that is observed in population studies investigating obesity.

  12. The Association of Telomere Length With Family Violence and Disruption

    Science.gov (United States)

    Mabile, Emily; Brett, Zoë H.; Esteves, Kyle; Jones, Edward; Shirtcliff, Elizabeth A.; Theall, Katherine P.

    2014-01-01

    BACKGROUND: To enhance the understanding of biological mechanisms connecting early adversity and negative health, we examine the association between family interpersonal violence and disruption and telomere length in youth. These specific exposures were selected because of their established links with negative health consequences across the life-course. METHODS: Children, age 5 to 15, were recruited from the greater New Orleans area, and exposure to family disruption and violence was assessed through caregiver report. Telomere length, from buccal cell DNA (buccal telomere length [bTL]), was determined by using monochrome multiplex quantitative real-time polymerase chain reaction. The association between bTL and adversity exposure was tested (n = 80). RESULTS: Cumulative exposure to interpersonal violence and family disruption was correlated with bTL. Controlling for other sociodemographic factors, bTL was significantly shorter in children with higher exposure to family violence and disruption. Witnessing family violence exerted a particularly potent impact. A significant gender interaction was found (β = −0.0086, SE = 0.0031, z test= −2.79, P = .0053) and analysis revealed the effect only in girls. CONCLUSIONS: bTL is a molecular biomarker of adversity and allostatic load that is detectable in childhood. The present results extend previous studies by demonstrating that telomeres are sensitive to adversity within the overarching family domain. These findings suggest that the family ecology may be an important target for interventions to reduce the biological impact of adversity in the lives of children. PMID:24936002

  13. The association of telomere length with family violence and disruption.

    Science.gov (United States)

    Drury, Stacy S; Mabile, Emily; Brett, Zoë H; Esteves, Kyle; Jones, Edward; Shirtcliff, Elizabeth A; Theall, Katherine P

    2014-07-01

    To enhance the understanding of biological mechanisms connecting early adversity and negative health, we examine the association between family interpersonal violence and disruption and telomere length in youth. These specific exposures were selected because of their established links with negative health consequences across the life-course. Children, age 5 to 15, were recruited from the greater New Orleans area, and exposure to family disruption and violence was assessed through caregiver report. Telomere length, from buccal cell DNA (buccal telomere length [bTL]), was determined by using monochrome multiplex quantitative real-time polymerase chain reaction. The association between bTL and adversity exposure was tested (n = 80). Cumulative exposure to interpersonal violence and family disruption was correlated with bTL. Controlling for other sociodemographic factors, bTL was significantly shorter in children with higher exposure to family violence and disruption. Witnessing family violence exerted a particularly potent impact. A significant gender interaction was found (β = -0.0086, SE = 0.0031, z test= -2.79, P = .0053) and analysis revealed the effect only in girls. bTL is a molecular biomarker of adversity and allostatic load that is detectable in childhood. The present results extend previous studies by demonstrating that telomeres are sensitive to adversity within the overarching family domain. These findings suggest that the family ecology may be an important target for interventions to reduce the biological impact of adversity in the lives of children. Copyright © 2014 by the American Academy of Pediatrics.

  14. New colour centres in KCl:(Tl+ + Ca2+) and KCl:(Tl+ + Sr2+) crystals

    International Nuclear Information System (INIS)

    Ioan, A.; Topa, V.; Giurgea, M.

    1978-01-01

    Electrolytic colouring under unusual conditions (low temperature and high voltage) gives rise to the appearance of three new absorption bands peaking at 3.2, 2.5, and 1.7 eV and at 2.8, 2.1, and 1.5 eV in KCl:(Tl + + Ca 2+ ) and in KCl:(Tl + + Sr 2+ ) single crystals, respectively. The modifications of the absorption spectra of the coloured crystals induced by the application of a reversed electric field at the colouring temperature or by heat treatment are investigated. It is likely that the colour centre responsible for the new absorption bands is an aggregate centre which, besides an Tl - -complex, contains also at least an Ca(Sr) ion, a trapped electron, and an anionic vacancy. (author)

  15. Copper interactions in TlCu7S4 and TlCu7Se4

    International Nuclear Information System (INIS)

    Noren, L.; Delaplane, R.G.; Berger, R.

    1999-01-01

    Complete text of publication follows. The copper chalcogenides ACu 7 S 4 (A=NH 4 + , Tl + , Rb + ) are quasi-one-dimensional metals at ambient and higher temperatures which is due to the high mobility of copper in these structures. TlCu 7 S 4 and TlCu 7 Se 4 are isostructural compounds, space group I4/m, which can be described on the basis of a TlX 8 cube with two different Cu sites, Cu(1) and Cu(2). Cu(2)-Cu(2) zigzag chains run along the c axis with only 3/4 occupation of the Cu(2) sites. However, these two compounds differ in behaviour on cooling. The sulphide shows a polymorphic first-order transition to the CsAg 7 S 4 type (P4/n) owing to ordering of the vacancies in the Cu(2)-Cu(2) chains. In order to study the nature of the Cu(2) order/disorder in the two title compounds, a series of neutron diffraction measurements (both Bragg and diffuse scattering) were made at several temperatures from 40 to 713 K on the instrument SLAD at Studsvik. The structure at each temperature was modelled using RMC techniques. The resulting configuration show that as the temperature increases, there is a marked increase in the mobility of the Cu atoms in the Cu(2)-Cu(2) chains for TlCu 7 S 4 but not for TlCu 7 Se 4 . This is due to the initial difference in the Cu(2)-Cu(2) distances, only 2.2A for the thiocuprate, but 2.7A in the selenocuprate which explains the relative ease for Cu(2) ordering in the latter case. (author)

  16. Insight on a novel layered semiconductors: CuTlS and CuTlSe

    Energy Technology Data Exchange (ETDEWEB)

    Aliev, Ziya S., E-mail: ziyasaliev@gmail.com [Institute of Catalysis and Inorganic Chemistry, ANAS, H.Javid ave. 113, AZ1143 Baku (Azerbaijan); Institute of Physics, ANAS, H.Javid ave. 131, AZ1143 Baku (Azerbaijan); Donostia International Physics Center (DIPC), 20080 San Sebastian (Spain); Zúñiga, Fco. Javier [Departamento de Física de la Materia Condensada, Facultad de Ciencia y Tecnología, Universidad del País Vasco, Apdo. 644, 48080 Bilbao (Spain); Koroteev, Yury M. [Institute of Strength Physics and Materials Science, Russian Academy of Sciences, Siberian Branch, 634055 Tomsk (Russian Federation); Tomsk State University, Tomsk, 634050 (Russian Federation); Breczewski, Tomasz [Departamento de Física de la Materia Condensada, Facultad de Ciencia y Tecnología, Universidad del País Vasco, Apdo. 644, 48080 Bilbao (Spain); Babanly, Nizamaddin B. [Institute of Catalysis and Inorganic Chemistry, ANAS, H.Javid ave. 113, AZ1143 Baku (Azerbaijan); Amiraslanov, Imamaddin R. [Institute of Physics, ANAS, H.Javid ave. 131, AZ1143 Baku (Azerbaijan); Politano, Antonio [Department of Physics, University of Calabria, 87036 Rende (CS) (Italy); Madariaga, Gotzon [Departamento de Física de la Materia Condensada, Facultad de Ciencia y Tecnología, Universidad del País Vasco, Apdo. 644, 48080 Bilbao (Spain); Babanly, Mahammad B. [Institute of Catalysis and Inorganic Chemistry, ANAS, H.Javid ave. 113, AZ1143 Baku (Azerbaijan); and others

    2016-10-15

    Single crystals of the ternary copper compounds CuTlS and CuTlSe have been successfully grown from stoichiometric melt by using vertical Bridgman-Stockbarger method. The crystal structure of the both compounds has been determined by powder and single crystal X-Ray diffraction. They crystallize in the PbFCl structure type with two formula units in the tetragonal system, space group P4/nmm, a=3.922(2); c=8.123(6); Z=2 and a=4.087(6); c=8.195(19) Å; Z=2, respectively. The band structure of the reported compounds has been analyzed by means of full-potential linearized augmented plane-wave (FLAPW) method based on the density functional theory (DFT). Both compounds have similar band structures and are narrow-gap semiconductors with indirect band gap. The resistivity measurements agree with a semiconductor behavior although anomalies are observed at low temperature. - Graphical abstract: The crystal structures of CuTl and CuTlSe are isostructural with the PbFCl-type and the superconductor LiFeAs-type tetragonal structure. The band structure calculations confirmed that they are narrow-gap semiconductors with indirect band gaps of 0.326 and 0.083 eV. The resistivity measurements, although confirming the semiconducting behavior of both compounds exhibit unusual anomalies at low temperatures. - Highlights: • Single crystals of CuTlS and CuTlSe have been successfully grown by Bridgman-Stockbarger method. • The crystal structure of the both compounds has been determined by single crystal XRD. • The band structure of the both compounds has been analyzed based on the density functional theory (DFT). • The resistivity measurements have been carried out from room temperature down to 10 K.

  17. Tl-201 per rectum scintigraphy in chronic liver disease: assessment of Tl-201 uptake indices

    International Nuclear Information System (INIS)

    Moon, Won Jin; Choi, Yun Young; Cho, Suk Shin; Lee, Min Ho

    1999-01-01

    Heart to liver ratio on Tl-201 per rectal scintigraphy (shunt index) is known to be useful in the assessment of portal systemic shunt. We assessed Tl-201 uptake pattern and early liver/heart uptake rate of Tl-201 and correlated with shunt index in patients with chronic active hepatitis (CAH) and liver cirrhosis (LC). Fifty eight patients with biopsy-proven chronic liver disease (35 with CAH, 23 with LC) underwent Tl-201 per rectum scintigraphy after instillation of 18.5 MBq of Tl-201 into the upper rectum. We evaluated hepatic uptake (type 1: homogeneous, 2: inhomogeneous segmental, 3: inhomogeneous nonsegmental) and extrahepatic uptake of spleen, heart and kidney (grade 0: no uptake, 1: less than liver, 2: equal to liver, 3: greater than liver). We measured the early liver/heart uptake rate (the slope of the liver to heart uptake ratio for 10 mim) and shunt index (heart to liver uptake ratio). Tl-201 uptake pattern and early liver/heart uptake rate of Tl-201 was correlated with the pathologic diagnosis and shunt index. Hepatic uptake patterns of type 1 and 2 were dominant in CAH (CAH: 27/35, LC: 8/23), and type 3 in LC (CAH: 8/35, LC: 15/23)(p<0.005). The grades of extrahepatic uptake were higher in LC than in CAH (spleen: p<0.001, other soft tissue: p<0.005). The early liver/heart uptake rate of CAH (0.110±0.111) was significantly higher than that of LC (0.014±0.090)(p<0.001). The sensitivity and specificity of the early liver/heart uptake rate were 77.7% and 67.7% in differentiating LC from CAH. There was negative correlation between early liver/heart uptake rate and shunt index (r=-0.3347, p<0.01). Hepatic and extrahepatic uptake pattern and early liver/heart uptake rate on Tl-201 per rectum scintigraphy are useful in the assessment of portal systemic shunt in patients with chronic liver disease

  18. 207Pb and 205Tl NMR on Perovskite Type Crystals APbX3 (A = Cs, Tl, X = Br, I)

    Science.gov (United States)

    Sharma, Surendra; Weiden, Norbert; Weiss, Alarich

    1987-11-01

    By 205Tl and 207Pb NM R the chemical shift in polycrystalline samples of binary halides AX, BX2 and ternary halides ABX3 (A = Cs, Tl; B = Pb; X = Br, I) was studied at room temperature. The chemical shift tensors δ ( 205Tl) and δ (207Pb) were determined in magnitude and orientation on single crystals of the orthorhombic TlPbI3. The components of the δ(205Tl) tensor are δx (205Tl) || a = 611ppm; δy (205Tl) || b = 680 ppm; δZ(205Tl) || c = 1329 ppm; δiso(205Tl) = 873.3 ppm (with respect to 3.4 molar aqueous solution of TlOOCCH3). The chemical shift tensor of 207Pb in TlPbI3 shows two orientations. One of them is: δx (207Pb) = 3760 ppm, inclined 30° from b towards c, δy(207Pb) || a = 3485 ppm, δz(207Pb) = 2639 ppm inclined 120° from b towards c. δiso(207Pb) = 3295 ppm (with respect to saturated aqueous solution of Pb(NO3)2). The results are discussed with respect to the crystal structure and a model to explain orientation and anisotropy of the tensors δ(205Tl) and δ(207Pb) in TlPbI3 is proposed. In the system CsPbBr3-x Ix δ(207Pb) was studied on polycrystalline samples. The chemical shift increases with increasing x and negative excess shift is observed.

  19. Intrinsic thermoluminescence of NaCl:Tl in UV dosimetry

    International Nuclear Information System (INIS)

    Barghare, S.P.; Joshi, R.V.; Joshi, T.R.; Kathuria, S.P.

    1982-01-01

    NaCl:Tl(T) phosphor is found to have high intrinsic thermoluminescence (TL) sensitivity to 253.7 nm UV-radiation. The dosimetric glow peak II grows sublinearly with increase in UV dose in the range 10 3 to 10 6 JM -2 . The other requirements of an efficient dosimeter material such as high storage stability, matching of the spectral response of detector tube and TL-emission from phosphor, reproducibility, desirable size and shape, easy availability in powder, pellet and crystal forms at cheaper rates, and repeated re-usability of the same phosphor without much difficulty, etc., are additional factors which strengthen the claim of NaCl:Tl(T) phosphor as UV dosimetric material. It is proposed that present NaCl:Tl(T) material is suitable TL-phosphor for UV dosimetry in the range 10 3 to 10 6 JM -2 . (author)

  20. Allometric relationships among body mass, MUZZLE-tail length, and tibia length during the growth of Wistar rats.

    Science.gov (United States)

    Santiago, Hildemberg Agostinho Rocha de; De Pierro, Lucas Rodolfo; Reis, Rafael Menezes; Caluz, Antônio Gabriel Ricardo Engracia; Ribeiro, Victor Barbosa; Volpon, José Batista

    2015-11-01

    To investigate allometric relationships among body mass (BM), muzzle-tail length (MTL), and tibia length (TL) in Wistar rats and establish their growth rate change parameters. Eighteen male and 18 female Wistar rats were studied from the 3rd to the 21st week of age. BM, MTL, and TL were measured daily, and relative growth was compared using allometry. A positive correlation between BM and MTL (p<0.05) and BM and TL (p<0.05) was observed. Males and females showed comparable curves; however, females had turning points at a younger age. The allometric relationship between BM and MTL presented a regular increase until reaching a mass of 351 g (males) and 405 g (females). BM and TL showed an initial increase until 185 g (males) and 182 g (females), and then reached a plateau that finished at 412 g (males) and 334 g (females), to display another increase. The allometric relationship of body mass with animal length and tibia length was comparable for male and female rats, with female rats maturing earlier. Animal longitudinal growth occurred in a single stage. In contrast, tibia length depicted two stages of accelerated growth with an intermediate period of deceleration.

  1. Improvements in the Tl dosimetry for Radiotherapy

    International Nuclear Information System (INIS)

    Bustos, S.; Velez, G.; Rubio, M.

    1998-01-01

    The thermoluminescent dosimetry (TLD) in vivo has been demonstrated to be one of the most reliable for the control of radiotherapeutic treatments, but the delay in the response is the main disadvantage in its applicability. In this work are presented important improvements and it is demonstrated that maintaining the accuracy and reliability of the technique, it is possible to accelerate the response times at a few hours. To realize this work is utilized a lecturer Harshaw 4000, dosemeters LiF-TLD-100 chips (3.1 x 3.1 x 0.89 mm 3 ) and rods (1 x 1 x 6 mm 3 ). With the implementation of a glow curve analysis program developed in CIEMAT, its obtained a Tl peaks separation in such manner rapid and accurate, by that the thermal treatment of dosemeters may be reduced at one unique annealing pre-irradiation for 1 hr at 400 Centigrade. It is realized a periodical and individual calibration of the TLD and a study of the factors which influencing the ratio Tl signal-dose as linearity, correction by energy, directional response and pride of Tl signal. the results of this study are introducing in a calculation list specially designed and which allows to obtain absorbed dose by TLD starting of the dates (dosimetric peaks area) which appear of the glow curves analysis. The dose is obtained with an accuracy less than 5 %. The dosemeters already irradiated (in vivo) are analysed and informed in only four hours, allowing a greater control of the treatment and a correction of the possible errors for the next session, still in bi fractional treatments. The method implemented results thus accurate, rapid and reliable. (Author)

  2. The TL dating of ancient porcelain

    International Nuclear Information System (INIS)

    Leung, P.L.; Stokes, M.J.; Wang Weida; Xia Junding; Zhou Zhixin

    1997-01-01

    The age determination of ancient porcelain using the pre-dose technique in TL dating was reported. The variation of beta dose with depth below the surface of the porcelain slice, the thermal activation characteristic (TAC) for 110 degree C peak, the measurement of paleodose and the estimation of annual dose were studied. The results show that this technique is suitable for authenticity testing of ancient porcelain, but both accuracy and precision for porcelain dating are worse than those for pottery, because porcelain differs from pottery on composition, structure and firing temperature. Besides, some complicated factors in the pre-dose technique would be the possible cause of the greater errors

  3. Prediction of Phase Separation of Immiscible Ga-Tl Alloys

    Science.gov (United States)

    Kim, Yunkyum; Kim, Han Gyeol; Kang, Youn-Bae; Kaptay, George; Lee, Joonho

    2017-06-01

    Phase separation temperature of Ga-Tl liquid alloys was investigated using the constrained drop method. With this method, density and surface tension were investigated together. Despite strong repulsive interactions, molar volume showed ideal mixing behavior, whereas surface tension of the alloy was close to that of pure Tl due to preferential adsorption of Tl. Phase separation temperatures and surface tension values obtained with this method were close to the theoretically calculated values using three different thermodynamic models.

  4. Reduction of total labor length through the addition of parenteral dextrose solution in induction of labor in nulliparous: results of DEXTRONS prospective randomized controlled trial.

    Science.gov (United States)

    Paré, Josianne; Pasquier, Jean-Charles; Lewin, Antoine; Fraser, William; Bureau, Yves-André

    2017-05-01

    Prolonged labor is a significant cause of maternal and fetal morbidity and very few interventions are known to shorten labor course. Skeletal muscle physiology suggests that glucose supplementation might improve muscle performance in case of prolonged exercise and this situation is analogous to the gravid uterus during delivery. Therefore, it seemed imperative to evaluate the impact of adding carbohydrate supplements on the course of labor. We sought to provide evidence as to whether intravenous glucose supplementation during labor induction in nulliparous women can reduce total duration of active labor. We performed a single-center prospective double-blind randomized controlled trial comparing the use of parental intravenous dextrose 5% with normal saline to normal saline in induced nulliparous women. The study was conducted in a tertiary-level university hospital setting. Participants, caregivers, and those assessing the outcomes were blinded to group assignment. Inclusion criteria were singleton pregnancy at term with cephalic presentation and favorable cervix. Based on blocked randomization, patients were assigned to receive either 250 mL/h of intravenous dextrose 5% with normal saline or 250 mL/h of normal saline for the whole duration of induction, labor, and delivery. The primary outcome studied was the total length of active labor. Secondary outcomes included duration of the active phase of second stage of labor, the mode of delivery, Apgar scores, and arterial cord pH. In all, 100 patients were randomized into each group. A total of 193 patients (96 in the dextrose with normal saline group and 97 in the normal saline group) were analyzed in the study. The median total duration of labor was significantly less in the dextrose with normal saline group (499 vs 423 minutes, P = .024) than in the normal saline group. The probabilities of a woman being delivered at 200 minutes and 450 minutes were 18.8% and 77.1% in the dextrose with normal saline group vs 8

  5. Characterization of cartilaginous tumors with 201Tl scintigraphy

    International Nuclear Information System (INIS)

    Higuchi, Takahiro; Taki, Junichi; Sumiya, Hisashi; Kinuya, Seigo; Nakajima, Kenichi; Tonami, Norihisa

    2005-01-01

    Histological diagnosis and grading of cartilaginous tumors are closely correlated with patient prognosis; consequently, they are essential elements. We attempted to clarify the characteristics of 201 Tl uptake in various histological types of cartilaginous tumors and to assess its clinical value. Twenty-two cases with histologically proven cartilaginous tumors (3 enchondromas, 15 conventional chondrosarcomas (grade I=9, II=5, III=1), 3 mesenchymal chondrosarcomas, and 1 de-differentiated chondrosarcoma) were examined retrospectively. Planar 201 Tl images were recorded 15 mm following intravenous injection of 201 Tl (111 MBq). 201 Tl uptake in the tumor was evaluated visually employing a five-grade scoring system: 0=no appreciable uptake, 1=faint uptake above the background level, 2=moderate uptake, 3=intense uptake but lower than heart uptake and 4=uptake higher than heart uptake. 201 Tl uptake scores were 0 in 3 of 3 enchondromas, 9 of 9 grade I, and 4 of 5 grade II conventional chondrosarcomas. 201 Tl uptake scores were 1 among 1 of 5 grades II and a grade III conventional chondrosarcoma. Mesenchymal chondrosarcoma and de-differentiated chondrosarcoma displayed 201 Tl uptake scores of 2 or 3. Absence of elevated 201 Tl uptake in cartilaginous tumors was indicative of enchondroma or low-grade conventional chondrosarcoma. However, in instances in which 201 Tl uptake is obvious, high-grade chondrosarcoma or variant types should be considered. (author)

  6. Methods, qualitative and quantitative evaluations of 201Tl myocardial scintiscans

    International Nuclear Information System (INIS)

    Buell, U.; Kleinhans, E.; Klepzig, M.; Seiderer, M.; Strauer, B.E.

    1981-01-01

    Exercise 201 Tl myocardial scintiscanning is a technique used to supplement exercise electrocardiography. The procedure employed should be identical to the standard procedure of electrocardiography. If the coronary disease has already been established by coronary angiography and kineventriculography, 201 Tl examinations should be carried out before surgery in order to determine the ''regional functional reserve''. Visual evaluations of the 201 Tl scintiscans should be supplemented by quantification methods. Quantification is also required between 201 Tl examination and surgery and to assure constant diagnostic accuracy in case of examination by different examiners. (orig./MG) [de

  7. NaI(Tl) response functions

    International Nuclear Information System (INIS)

    Vega C, H. R.; Ortiz R, J. M.; Benites R, J. L.; De Leon M, H. A.

    2015-09-01

    The response functions of a NaI(Tl) detector have been estimated using Monte Carlo methods. Response functions were calculated for monoenergetic photon sources (0.05 to 3 MeV). Responses were calculated for point-like sources and for sources distributed in Portland cement cylinders. The responses were used to calculate the efficiency functions in term of photon energy. Commonly, sources used for calibration are point-like, and eventually sources to be measured have different features. In order to use the calibrated sources corrections due to solid angle, self-absorption and scattering, must be carried out. However, some of these corrections are not easy to perform. In this work, the calculated responses were used to estimate the detector efficiency of point-like sources, and sources distributed in Portland type cement. Samples of Portland paste were prepared and were exposed to photoneutrons produced by a 15 MV linac. Some of the elements in the cement were activated producing γ-emitting radionuclides that were measured with a NaI(Tl) gamma-ray spectrometer, that was calibrated with point-like sources. In order to determine the specific activity in the induced radioisotopes calculated efficiencies were used to make corrections due to the differences between the solid angle, photon absorption and photon scattering in the point-like calibration sources and the sources distributed in cement. During the interaction between photoneutrons and the cement samples three radioisotopes were induced: 56 Mn, 24 Na, and 28 Al. (Author)

  8. Leukocyte telomere length and late-life depression

    NARCIS (Netherlands)

    Schaakxs, R.; Verhoeven, J.E.; Oude Voshaar, R.C.; Comijs, H.C.; Penninx, B.W.

    2015-01-01

    Objective Depressive disorders have been associated with increased risk for aging-related diseases, possibly as a consequence of accelerated cellular aging. Cellular aging, indexed by telomere length (TL) shortening, has been linked to depression in adults younger than 60 years; however, it remains

  9. [Tl(III)(dota)](-): An Extraordinarily Robust Macrocyclic Complex.

    Science.gov (United States)

    Fodor, Tamás; Bányai, István; Bényei, Attila; Platas-Iglesias, Carlos; Purgel, Mihály; Horváth, Gábor L; Zékány, László; Tircsó, Gyula; Tóth, Imre

    2015-06-01

    The X-ray structure of {C(NH2)3}[Tl(dota)]·H2O shows that the Tl(3+) ion is deeply buried in the macrocyclic cavity of the dota(4-) ligand (1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetate) with average Tl-N and Tl-O distances of 2.464 and 2.365 Å, respectively. The metal ion is directly coordinated to the eight donor atoms of the ligand, which results in a twisted square antiprismatic (TSAP') coordination around Tl(3+). A multinuclear (1)H, (13)C, and (205)Tl NMR study combined with DFT calculations confirmed the TSAP' structure of the complex in aqueous solution, which exists as the Λ(λλλλ)/Δ(δδδδ) enantiomeric pair. (205)Tl NMR spectroscopy allowed the protonation constant associated with the protonation of the complex according to [Tl(dota)](-) + H(+) ⇆ [Tl(Hdota)] to be determined, which turned out to be pK(H)Tl(dota) = 1.4 ± 0.1. [Tl(dota)](-) does not react with Br(-), even when using an excess of the anion, but it forms a weak mixed complex with cyanide, [Tl(dota)](-) + CN(-) ⇆ [Tl(dota)(CN)](2-), with an equilibrium constant of Kmix = 6.0 ± 0.8. The dissociation of the [Tl(dota)](-) complex was determined by UV-vis spectrophotometry under acidic conditions using a large excess of Br(-), and it was found to follow proton-assisted kinetics and to take place very slowly (∼10 days), even in 1 M HClO4, with the estimated half-life of the process being in the 10(9) h range at neutral pH. The solution dynamics of [Tl(dota)](-) were investigated using (13)C NMR spectroscopy and DFT calculations. The (13)C NMR spectra recorded at low temperature (272 K) point to C4 symmetry of the complex in solution, which averages to C4v as the temperature increases. This dynamic behavior was attributed to the Λ(λλλλ) ↔ Δ(δδδδ) enantiomerization process, which involves both the inversion of the macrocyclic unit and the rotation of the pendant arms. According to our calculations, the arm-rotation process limits the Λ(λλλλ) ↔

  10. On clinical usefulness of Tl-201 scintigraphy for the management of malignant soft tissue tumors

    International Nuclear Information System (INIS)

    Terui, Shoji; Terauchi, Takashi; Abe, Hiroyuki; Fukuma, Hisatoshi; Beppu, Yasuo; Chuman, Koichi; Yokoyama, Ryohei

    1994-01-01

    The purpose of this study was to investigate Tl-201 as a tumor scanning agent in patients with malignant soft tissue sarcomas and to establish the sensitivity of this type of scintigraphy concerning local recurrences or metastases that may remain clinically suspected. Seventy-eight patients with malignant soft tissue sarcomas and 22 with benign soft tissue tumors were studied. Of these 78 malignant soft tissue sarcomas patients, the sensitivity of Tl-201 (81.2%) was higher than that of Ga-67 (68.8%). Thirty-three out of 78 patients received a total of 95 consecutive scintigraphic follow-up examinations. Therapeutic effects was assessed by comparing the results of Tl-201 examinations with the clinical findings. Of these 33 patients, the therapeutic effects observed were as follows: complete remission 1, partial remission 8, progress of disease 1, and no remarkable change 23. Tl-201 scintigraphy has proved itself very useful not only in clinically detecting the malignant soft tissue sarcomas and in assessing therapeutic effects on these diseases, but also in assessing the follow-up patients with malignant soft tissue sarcomas. (author)

  11. Phytotoxicity of thallium (Tl) in culture solution. Pt. 1. Effects of Tl(I) on the growth and heavy metal contents of pea and field bean plants

    Energy Technology Data Exchange (ETDEWEB)

    Poetsch, U; Austenfeld, F A

    1985-01-01

    The effects of TlNO/sub 3/ and Tl(I)EDTA on growth and heavy metal contents of pea plants and field bean plants were compared in hydroponic culture experiments. In the presence of TlNO/sub 3/, the essential heavy metals were available to the plants in their ionic forms. When Tl(I)EDTA was present the essential heavy metals were available as chelated complexes. With increasing concentration of TlNO/sub 3/ dry matter production of pea plants was lowered and the Tl content of each organ was increased. The highest Tl content was found within the stems. The increased Tl contents were accompanied by depressed Mn, Zn, and Cu contents of the roots and depressed Mn contents of the stems, but increased Fe contents of the stems. Substitution of TlNO/sub 3/ by Tl(I)EDTA resulted in a stronger growth inhibition of the pea plants, and higher Tl contents of each organ. The highest Tl content was found within the stems. Tl(I)EDTA depressed Mn in the roots, but increased Fe and Mn in the stems, and Fe, Zn and Cu in the leaves. The increases may due to concentration by growth inhibition. The growth of the field bean was not effected by TlNO/sub 3/ nor by Tl(I)EDTA. The field bean contained most of the Tl within the roots and translocated only relatively small amounts to the shoots. This pattern was independent of the Tl compound. Increasing concentrations of TlNO/sub 3/ resulted in depressed Mn and Zn contents of the roots, and Mn contents of the stems. Chelation of Tl(I) resulted in a decrease of the Tl content of each organ. Tl(I)EDTA depressed only the Mn content of the roots.

  12. Telomere length dynamics in human memory T cells specific for viruses causing acute or latent infections.

    Science.gov (United States)

    O'Bryan, Joel M; Woda, Marcia; Co, Mary; Mathew, Anuja; Rothman, Alan L

    2013-08-26

    Declining telomere length (TL) is associated with T cell senescence. While TL in naïve and memory T cells declines with increasing age, there is limited data on TL dynamics in virus-specific memory CD4+ T cells in healthy adults. We combined BrdU-labeling of virus-stimulated T cells followed with flow cytometry-fluorescent in situ hybridization for TL determination. We analyzed TL in T cells specific for several virus infections: non-recurring acute (vaccinia virus, VACV), recurring-acute (influenza A virus, IAV), and reactivating viruses (varicella-zoster virus, VZV, and cytomegalovirus, CMV) in 10 healthy subjects. Additionally, five subjects provided multiple blood samples separated by up to 10 years. VACV- and CMV-specific T cells had longer average TL than IAV-specific CD4+ T cells. Although most virus-specific cells were CD45RA-, we observed a minor population of BrdU+ CD45RA+ T cells characterized by long telomeres. Longitudinal analysis demonstrated a slow decline in average TL in virus-specific T cells. However, in one subject, VZV reactivation led to an increase in average TL in VZV-specific memory T cells, suggesting a conversion of longer TL cells from the naïve T cell repertoire. TLs in memory CD4+ T cells in otherwise healthy adults are heterogeneous and follow distinct virus-specific kinetics. These findings suggests that the distribution of TL and the creation and maintenance of long TL memory T cells could be important for the persistence of long-lived T cell memory.

  13. The TL and OSL study of hydroxyapatites for dosimetric applications

    International Nuclear Information System (INIS)

    Alencar, Marcus A. Vallim de

    2009-01-01

    The hydroxyapatite, the principal mineral component of the bone and tooth enamel, is one of the dosimetric materials that has distinguished itself in the high dose and accidents dosimetry, as well as in the dating, for the Electron Paramagnetic Resonance (EPR) technique. For this reason, the hydroxyapatite could also be used as Thermoluminescence (TL) and Optically Stimulated Luminescence (OSL) dosimeter in the dosimetry of high doses and accidents, and also in the archaeological and geological dating. This work presents a brief study of the TL and OSL behaviour of the B type synthetic carbonated hydroxyapatite, observing the possibility to use this material in TL and OSL dosimetry. The samples were irradiated to a dose of 100 Gy and 1000 Gy, and the TL and OSL measurements were obtained by the RISOE TL/OSL reader, model TL/OSL-DA-15B. The first results demonstrate the presence of three peaks in the TL glow curve in the temperatures of 100 deg C, 150 deg C and 280 deg C. The synthetic carbonated hydroxyapatite also presents an OSL signal when the sample is stimulated with blue light and a small OSL signal for stimulation with infrared light (IR). These results indicate the possibility of this synthetic carbonated hydroxyapatite to be used as dose indicator material using the TL and OSL techniques. (author)

  14. Leading the Charge for SoTL--Embracing Collaboration

    Science.gov (United States)

    Cassard, Anita; Sloboda, Brian

    2014-01-01

    The scholarship of teaching and learning (SoTL) enables colleges and universities to assess student learning and measure the outcomes by engaging in meaningful research, and to disseminate this research. The objective of this paper is to give a snapshot of and assess the current thinking behind this scholarship by presenting examples of SoTL, and…

  15. Abnormal 201Tl limb scan due to unilateral tremor

    International Nuclear Information System (INIS)

    Simons, M.; Schelstraete, K.; Bratzlavsky, M.

    1982-01-01

    A abnormal intra- and interextremity distribution pattern on 201 Tl was observed on the limb scan of a patient with a unilateral tremor. This is ascribed to the increased blood flow in the muscles responsible for the tremor. The suggestion is made that the existence of tremor should be considered as a possible explanation for unexpected abnormalities on 201 Tl limb scintigrams

  16. Kinetic parameters and TL mechanism in cadmium tetra borate phosphor

    International Nuclear Information System (INIS)

    Annalakshmi, O.; Jose, M.T.; Sridevi, J.; Venkatraman, B.; Amarendra, G.; Mandal, A.B.

    2014-01-01

    Polycrystalline powder samples of cadmium tetra borate were synthesized by a simple solid state sintering technique and gamma irradiated sample showed a simple Thermoluminescence (TL) glow peak around 460 K. The TL kinetic parameters of gamma irradiated phosphor were determined by initial rise (IR), isothermal decay (ID), peak shape (PS), variable heating rate (VHR) and glow curve de-convolution method. The kinetic parameters such as activation energy (E), frequency factor (s) and order of kinetics (b) were calculated by IR, ID, PS and VHR methods are in the order of ∼1.05 eV, 10 9 –10 12 s −1 and 1.58, respectively. From the results of TL and PL emission studies carried out on the phosphor revealed that the defect centers related to TL is different from that for PL. EPR measurements were carried out to identify the defect centers formed in cadmium tetra borate phosphor on gamma irradiation. Based on EPR studies the mechanism for TL process in cadmium tetra borate is proposed in this paper -- Highlights: • Polycrystalline powder samples of undoped cadmium tetra borate synthesized. • Cadmium tetra borate phosphor exhibits a dosimetric peak at 458 K. • Kinetic parameters of the trap responsible for TL evaluated. • TL mechanism is proposed from TL to EPR correlation studies

  17. Kinetic parameters and TL mechanism in cadmium tetra borate phosphor

    Energy Technology Data Exchange (ETDEWEB)

    Annalakshmi, O. [Radiological Safety Division, Materials Physics Division, Indira Gandhi Centre for Atomic Research, Kalpakkam-603102 (India); Jose, M.T., E-mail: mtj@igcar.gov.in [Radiological Safety Division, Materials Physics Division, Indira Gandhi Centre for Atomic Research, Kalpakkam-603102 (India); Sridevi, J. [Central Leather Research Institute, Council of Scientific and Industrial Research, Chennai 600 020, Tamilnadhu (India); Venkatraman, B. [Radiological Safety Division, Materials Physics Division, Indira Gandhi Centre for Atomic Research, Kalpakkam-603102 (India); Amarendra, G. [Materials Physics Division, Indira Gandhi Centre for Atomic Research, Kalpakkam-603102 (India); Mandal, A.B. [Central Leather Research Institute, Council of Scientific and Industrial Research, Chennai 600 020, Tamilnadhu (India)

    2014-03-15

    Polycrystalline powder samples of cadmium tetra borate were synthesized by a simple solid state sintering technique and gamma irradiated sample showed a simple Thermoluminescence (TL) glow peak around 460 K. The TL kinetic parameters of gamma irradiated phosphor were determined by initial rise (IR), isothermal decay (ID), peak shape (PS), variable heating rate (VHR) and glow curve de-convolution method. The kinetic parameters such as activation energy (E), frequency factor (s) and order of kinetics (b) were calculated by IR, ID, PS and VHR methods are in the order of ∼1.05 eV, 10{sup 9}–10{sup 12} s{sup −1} and 1.58, respectively. From the results of TL and PL emission studies carried out on the phosphor revealed that the defect centers related to TL is different from that for PL. EPR measurements were carried out to identify the defect centers formed in cadmium tetra borate phosphor on gamma irradiation. Based on EPR studies the mechanism for TL process in cadmium tetra borate is proposed in this paper -- Highlights: • Polycrystalline powder samples of undoped cadmium tetra borate synthesized. • Cadmium tetra borate phosphor exhibits a dosimetric peak at 458 K. • Kinetic parameters of the trap responsible for TL evaluated. • TL mechanism is proposed from TL to EPR correlation studies.

  18. ESR and TL age determination of caliche nodules

    Energy Technology Data Exchange (ETDEWEB)

    Oezer, A.M. (Middle East Technical Univ., Ankara (Turkey)); Wieser, A.; Goeksu, H.Y.; Mueller, P.; Regulla, D.F. (Gesellschaft fuer Strahlen- und Umweltforschung mbH Muenchen, Neuherberg (Germany, F.R.). Inst. fuer Strahlenschutz); Erol, O. (Istanbul Univ. (Turkey). School of Geography and Marine Sciences)

    1989-01-01

    Feasibility of dating caliche nodules by ESR and TL is investigated. For both methods the properties of the dating signal are described. Chemical composition as well as TL glow curves of caliches originating from different localities exhibit some differences. Due to the complexity of the TL glow curves, some samples required a special post-annealing procedure in order to resolve the main TL peak for age determination. Typical ESR calcite signals do not exist in caliche, therefore usefulness of the g=2.0040 ESR signal is studied. The results of TL and ESR ages are found to be compatible except for two samples. Possible causes of the discrepancy in these samples are discussed. It is shown that, with proper treatment of the radiation-induced signals, it was possible to date caliche formations older than 350 ka, which is not achievable with other methods like uranium series disequilibrium and/or radiocarbon dating. (author).

  19. ESR and TL age determination of caliche nodules

    International Nuclear Information System (INIS)

    Oezer, A.M.; Wieser, A.; Goeksu, H.Y.; Mueller, P.; Regulla, D.F.; Erol, O.

    1989-01-01

    Feasibility of dating caliche nodules by ESR and TL is investigated. For both methods the properties of the dating signal are described. Chemical composition as well as TL glow curves of caliches originating from different localities exhibit some differences. Due to the complexity of the TL glow curves, some samples required a special post-annealing procedure in order to resolve the main TL peak for age determination. Typical ESR calcite signals do not exist in caliche, therefore usefulness of the g=2.0040 ESR signal is studied. The results of TL and ESR ages are found to be compatible except for two samples. Possible causes of the discrepancy in these samples are discussed. It is shown that, with proper treatment of the radiation-induced signals, it was possible to date caliche formations older than 350 ka, which is not achievable with other methods like uranium series disequilibrium and/or radiocarbon dating. (author)

  20. The automated Risoe TL dating reader system

    International Nuclear Information System (INIS)

    Boetter-Jensen, L.

    1988-01-01

    The features of the new modified Riso TL dating reader system are described. A vacuum chamber that accommodates the entire 24-position sample changer unit has been designed. The vacuum and N 2 -gas functions are software-controlled. A newly designed heater system is capable of repeated heating cycles to 700 0 C. The sample changer system accommodates fine-grain discs as well as planchettes for coarse grains. Two software-controlled beta irradiators can be attached to the reader, e.g. for predose measurement. The software allows a user without programming expertise to create any desired measuring sequence, and to store and recall data and glow curves for making analyses. (author)

  1. Evaluasi Pengendalian Sistem Informasi Pengiriman pada TL

    Directory of Open Access Journals (Sweden)

    Nelly Nelly

    2011-06-01

    Full Text Available The purpose of this study is to evaluate the control systems on the TL shipping information, in order to discern weaknesses or problems in delivery of enterprise information systems control using CobIT approach. The research method used is the data collecting by observation, checklists, interviews, and literature study. The results achieved are findings and issue recommendations that provide an illustration about a control of the running information delivery systems. From the illustration it is known that on the company’s control of information delivery system, there are still many things that have not been up to standard. The conclusion obtained is that the control of information delivery systems that have been implemented meets only partially the standards set small, so it still needs much improvement. 

  2. Quality control 201TlCl solution obtained at IPEN-CNEN/SP through the direct method of 201Tl preparation

    International Nuclear Information System (INIS)

    Fernandes, L.; Silva, C.P.G. da.

    1991-09-01

    The radiopharmaceutical 201 TlCl is used in Nuclear medicine for myocardial visualization. The solution of 201 TlCl was prepared using 201 Tl obtained by irradiating a natural mercury target with protons. This radionuclide was subjected to different quality control processes to verify the purity required for its use in Medicine. Some of these controls concerned the determination of 200 Tl, 201 Tl and 202 Tl; the chemical identification of 201 Tl +1 ; the hydrazine concentration, mercury contamination and the presence of phosphate. Furthermore, the biologic distribution in Wistar rats and tests for sterility, pyrogens and for toxicity were carried out. It was verified that the solution obtained was in the form of thallous chloride. This radiopharmaceutical can give a good heart image in animals but due to the contamination of 201 Tl with 200 Tl and 202 Tl its use in human beings is not possible unless enriched 202 Hg is used as target of irradiation. (author)

  3. Clinical use of 201Tl myocardial scintigraphy

    International Nuclear Information System (INIS)

    Senda, Kohei; Imaeda, Takeyoshi; Kato, Toshimitsu; Asada, Shuichi; Doi, Hidetaka

    1977-01-01

    Myocardial imaging with 201 Tl and scinticamera was studied experimentally using specially designed phantoms and clinically in 23 patients with myocardial infarction or other heart disease. In the phantom experiment, quality of image, accumulative count rate, and detectability of the defect were compared to obtain the best technique for their detection, using four different collimators, i.e., converging, pin-hole, 4000-hole, and 140 keV high-resolution, at two photopeak levels of 201 Tl of 75 and 167 keV, and combining a radiation absorber. In patient examination, myocardial images taken at different periods after injection, different detecting conditions of the scinticamera, and various detecting projections were compared. Images of the converging collimator at the 75 keV photopeak revealed considerably higher accumulative counts and relatively higher quality than those of other detecting conditions. It was necessary to take as many images as possible in various projections, in order to detect the location and size of the myocardial ischemic lesion because the lesion was demonstrated as a clear defect only in profile. It became evident that images taken between about 25 and 90 min delineated the myocardium more clearly than those taken in other periods. Normal images taken in 8 patients without ischemic heart disease appeared in the shape of a doughnut of horseshoe, demonstrating mainly the left venticular myocardium. The image was faint in the region of the aortic or mitral valve and thin in the region of the apical wall. A faint image of the right ventricular myocardium was sometimes seen. In 3 patients with valvular heart disease, findings suggested changes in the thickness of myocardium and the distribution of coronary blood flow. In 11 of 12 patients with old myocardial infarction, the location and size of the lesion was detected. (Evans, J.)

  4. NaI(Tl) response functions

    Energy Technology Data Exchange (ETDEWEB)

    Vega C, H. R.; Ortiz R, J. M. [Universidad Autonoma de Zacatecas, Unidad Academica de Estudios Nucleares, Cipres No. 10, Fracc. La Penuela, 98068 Zacatecas, Zac. (Mexico); Benites R, J. L. [Centro Estatal de Cancerologia de Nayarit, Calz. de la Cruz 118 Sur, Tepic, Nayarit (Mexico); De Leon M, H. A., E-mail: fermineutron@yahoo.com.mx [Instituto Tecnologico de Aguascalientes, Av. Adolfo Lopez Mateos 1801 Ote., 20155 Aguascalientes, Ags. (Mexico)

    2015-09-15

    The response functions of a NaI(Tl) detector have been estimated using Monte Carlo methods. Response functions were calculated for monoenergetic photon sources (0.05 to 3 MeV). Responses were calculated for point-like sources and for sources distributed in Portland cement cylinders. The responses were used to calculate the efficiency functions in term of photon energy. Commonly, sources used for calibration are point-like, and eventually sources to be measured have different features. In order to use the calibrated sources corrections due to solid angle, self-absorption and scattering, must be carried out. However, some of these corrections are not easy to perform. In this work, the calculated responses were used to estimate the detector efficiency of point-like sources, and sources distributed in Portland type cement. Samples of Portland paste were prepared and were exposed to photoneutrons produced by a 15 MV linac. Some of the elements in the cement were activated producing γ-emitting radionuclides that were measured with a NaI(Tl) gamma-ray spectrometer, that was calibrated with point-like sources. In order to determine the specific activity in the induced radioisotopes calculated efficiencies were used to make corrections due to the differences between the solid angle, photon absorption and photon scattering in the point-like calibration sources and the sources distributed in cement. During the interaction between photoneutrons and the cement samples three radioisotopes were induced: {sup 56}Mn, {sup 24}Na, and {sup 28}Al. (Author)

  5. Light yield of a CsI(Tl) crystal under irradiation by protons with the energy from 3 to 15 MeV

    International Nuclear Information System (INIS)

    Dorchoman, D.; Konstantin, M.; Lazarovich, D.; Muntyanu, I.; Oganesyan, K.O.; Porokhovoj, S.Yu.

    1976-01-01

    Measurement results are presented of light yield in CsI(Tl) crystals at the irradiation by protons with the energy from 3 to 15 MeV. Plates of 100x100x2 mm size are used as CsI(Tl) scintillator samples. A brief analysis of possible sistematic errors is given which allows to estimate the total error upon the light yield valve determination equal to 0,5%. Measurement results of crystal light yield show that the dependence of CsI(Tl) light yield on proton energy is described by the straight line passing through the origin

  6. Photoluminescence and absorption spectra of various common TL phosphors - interpretation of TL mechanisms

    International Nuclear Information System (INIS)

    Nagpal, J.S.

    1980-01-01

    Photoluminescence and absorption spectra of TL phosphors TLD-100, CaF 2 :Dy, CaSO 4 :Dy(0.05%wt), CaSO 4 :Tm(0.05%wt) and Mg 2 SiO 4 :Tb have been measured. The absorption spectra are typical of RE 2+ in rare earth doped irradiated phosphors. On heating RE 2+ yields RE 3+ and emission from the excited states of RE 3+ is observed. (author)

  7. Right ventricular visualization by Tl-201 myocardial scintigraphy in chronic obstructive pulmonary disease

    Energy Technology Data Exchange (ETDEWEB)

    Fujii, Tadashige; Tanaka, Masao; Takeda, Masashi; Matsuzawa, Yukinori; Handa, Kenjiro; Yoshimura, Kazuhiko [Shinshu Univ., Matsumoto, Nagano (Japan). Faculty of Medicine

    1993-04-01

    Tl-201 myocardial scintigraphy was performed in 130 patients with chronic obstructive pulmonary disease (COPD) to evaluate right ventricular hypertrophy, and the clinical significance of this method was studied. Tl-201 uptake ratios of the right ventricle, which represents the ratio of total counts of the right ventricle to counts of the administered dose of Tl-201, was higher in COPD, especially in pulmonary emphysema and B type COPD by Burrows classification than in controls. The grade of visualization of the right ventricle by visual assessment (RVV) was marked (+++) in only a few cases and moderate (++) in many cases (more than 80%) in all diseases except bronchial asthma. The incidence of right ventricular hypertrophy by electrocardiogram, right-sided heart failure and marked dyspnea (Hugh-Jones 4[center dot]5) were very low in cases with RVV grade ++ and very high in cases with +++. The grade of RVV was related to the severity of pulmonary perfusion impairment, although in diffuse panbronchiolitis the RVV was relatively slight compared with the impairment of perfusion. May parameters of pulmonary function such as %VC, FEV1.0%, RV/TLC, V25, %DLCO, Raw, [Delta]N[sub 2] and PaO[sub 2] showed abnormal values in patients with RVV grade of (++) or (+++) in all diseases except bronchial asthma. In COPD, Tl-201 myocardial scintigraphy seems to be useful for assessment of right ventricular overloading, and for follow-up observation and differentiation between cor pulmonale and right ventricular hypertrophy secondary to cardiac diseases by observing Tl-201 uptake of the lung and left ventricle. (author).

  8. Right ventricular visualization by Tl-201 myocardial scintigraphy in chronic obstructive pulmonary disease

    International Nuclear Information System (INIS)

    Fujii, Tadashige; Tanaka, Masao; Takeda, Masashi; Matsuzawa, Yukinori; Handa, Kenjiro; Yoshimura, Kazuhiko

    1993-01-01

    Tl-201 myocardial scintigraphy was performed in 130 patients with chronic obstructive pulmonary disease (COPD) to evaluate right ventricular hypertrophy, and the clinical significance of this method was studied. Tl-201 uptake ratios of the right ventricle, which represents the ratio of total counts of the right ventricle to counts of the administered dose of Tl-201, was higher in COPD, especially in pulmonary emphysema and B type COPD by Burrows classification than in controls. The grade of visualization of the right ventricle by visual assessment (RVV) was marked (+++) in only a few cases and moderate (++) in many cases (more than 80%) in all diseases except bronchial asthma. The incidence of right ventricular hypertrophy by electrocardiogram, right-sided heart failure and marked dyspnea (Hugh-Jones 4·5) were very low in cases with RVV grade ++ and very high in cases with +++. The grade of RVV was related to the severity of pulmonary perfusion impairment, although in diffuse panbronchiolitis the RVV was relatively slight compared with the impairment of perfusion. May parameters of pulmonary function such as %VC, FEV1.0%, RV/TLC, V25, %DLCO, Raw, ΔN 2 and PaO 2 showed abnormal values in patients with RVV grade of (++) or (+++) in all diseases except bronchial asthma. In COPD, Tl-201 myocardial scintigraphy seems to be useful for assessment of right ventricular overloading, and for follow-up observation and differentiation between cor pulmonale and right ventricular hypertrophy secondary to cardiac diseases by observing Tl-201 uptake of the lung and left ventricle. (author)

  9. Longitudinal patterns in flathead catfish relative abundance and length at age within a large river: Effects of an urban gradient

    Science.gov (United States)

    Paukert, C.P.; Makinster, A.S.

    2009-01-01

    We investigated the spatial variation of flathead catfish (Pylodictis olivaris) relative abundance and growth in the 274 km long Kansas River to determine if population dynamics of catfish are related to urbanization. Electrofishing was conducted at 462 random sites throughout the river in summer, 2005-2006 to collect fish. Relative abundance of age 1 fish (???200mm), subadult (>200-400mm) and adult fish (>400 mm) ranged from 0.34 to 14.67 fish h-1, mean length at age 1 was 165 (range: 128-195) mm total length (TL) and mean length at age 3 was 376 mm TL (range: 293-419mm TL). The proportion of land use within 200 m of the river edge was between 0 and 0.54 urban. River reaches with high relative abundance of age 1 flathead catfish had high relative abundance of subadult and adult catfish. River reaches with fast flathead catfish growth to age 1 had fast growth to age 3. High urban land use and riprap in the riparian area were evident in river reaches near the heavily populated Kansas City and Topeka, Kansas, USA. Reaches with increased number of log jams and islands had decreased riparian agriculture. Areas of low urbanization had faster flathead catfish growth (r = 0.67, p = 0.005). Relative abundance of flathead catfish was higher in more agricultural areas (r = -0.57, p = 0.02). Changes in land use in riverine environments may alter population dynamics of a fish species within a river. Spatial differences in population dynamics need to be considered when evaluating riverine fish populations. Published in 2008 by John Wiley & Sons Ltd.

  10. Pulse shaper for scintillation detectors with NaI(Tl) or CsI(Tl) crystals

    International Nuclear Information System (INIS)

    Novisov, B.S.; Maksimenko, A.S.; Baryshev, A.V.; Zhukov, A.V.

    1978-01-01

    The basic circuit of a signal shaper for scintillation detectors with NaI(Tl) and CsI(Tl) crystals is described. To increase amplitude resolution, it is suggested to integrate not the whole charge at the photomultiplier output, but a part of the charge during the initial 100 ns of the current pulse; the remaining part of the current signal is compensated directly at the photomultiplier anode by means of an electric circuit. The principal elements of the spectrometric signal shaper include an input transistor amplifier, a compensation circuit, a key element, a shaper amplifier of time pulses, a shaper of signal duration for controlling the key element, and an output spectrometric amplifier. This device, being used, one can shape pulses at durations of 100 ns and more. The shaper restoration time does not exceed 50 ns. When the shaper operates with NaI(Tl) crystals and at counting rate of 10 6 pulse/s, the amplitude resolution with and without the compensation circuit is 17% and 21% respectively

  11. Simulation of the peak efficiency for a stacked NaI(Tl) spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Yoshida, H; Murohka, H; Anami, K; Nohtomi, A; Uozumi, Y; Sakae, T; Matoba, M [Kyushu Univ., Fukuoka (Japan). Faculty of Engineering; Koori, N; Maki, T

    1996-07-01

    A stacked NaI(Tl) spectrometer has been developed to measure proton spectra in wide energy range. In the measurement of charged particles with intermediate energy, the detecting efficiency of the spectrometer decreases considerably due to nuclear reactions or out-scattering in the detector material. A Monte Carlo simulation code has been developed to estimate the peak efficiency (peak-to-total ratio) of the spectrometer. The calculated efficiency for intermediate energy is in good agreement with the experimental one. (author)

  12. Emergence of topological and topological crystalline phases in TlBiS2 and TlSbS2

    KAUST Repository

    Zhang, Qingyun; Cheng, Yingchun; Schwingenschlö gl, Udo

    2015-01-01

    Using first-principles calculations, we investigate the band structure evolution and topological phase transitions in TlBiS2 and TlSbS2 under hydrostatic pressure as well as uniaxial and biaxial strain. The phase transitions are identified by parity analysis and by calculating the surface states. Zero, one, and four Dirac cones are found for the (111) surfaces of both TlBiS2 and TlSbS2 when the pressure grows, which confirms trivial-nontrivial-trivial phase transitions. The Dirac cones at the (M) over bar points are anisotropic with large out-of-plane component. TlBiS2 shows normal, topological, and topological crystalline insulator phases under hydrostatic pressure, thus being the first compound to exhibit a phase transition from a topological to a topological crystalline insulator.

  13. Emergence of topological and topological crystalline phases in TlBiS2 and TlSbS2

    KAUST Repository

    Zhang, Qingyun

    2015-02-11

    Using first-principles calculations, we investigate the band structure evolution and topological phase transitions in TlBiS2 and TlSbS2 under hydrostatic pressure as well as uniaxial and biaxial strain. The phase transitions are identified by parity analysis and by calculating the surface states. Zero, one, and four Dirac cones are found for the (111) surfaces of both TlBiS2 and TlSbS2 when the pressure grows, which confirms trivial-nontrivial-trivial phase transitions. The Dirac cones at the (M) over bar points are anisotropic with large out-of-plane component. TlBiS2 shows normal, topological, and topological crystalline insulator phases under hydrostatic pressure, thus being the first compound to exhibit a phase transition from a topological to a topological crystalline insulator.

  14. Development of low background CsI(Tl) and NaI(Tl) crystals for WIMP search

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Hyun Su [Department of Physics, Ewha Womans University, Seoul 120-750 (Korea, Republic of)

    2015-08-17

    We have developed low background CsI(Tl) and NaI(Tl) crystals to search for weakly interacting massive particles as well as to verify the origin of the annual modulation signal observed by the DAMA/LIBRA experiment. Extensive studies about the contamination mechanisim of {sup 137}Cs in CsI powder lead to the growth of ultra-low-background CsI(Tl) crystals. Similar approaches for NaI(Tl) crystals have been applied to reduce internal backgrounds to less than 0.5 counts/kg/day/keV. Status and understanding of backgrounds and background reduction in NaI(Tl) crystals will be discussed.

  15. Serum albumin levels in burn people are associated to the total body surface burned and the length of hospital stay but not to the initiation of the oral/enteral nutrition.

    Science.gov (United States)

    Pérez-Guisado, Joaquín; de Haro-Padilla, Jesús M; Rioja, Luis F; Derosier, Leo C; de la Torre, Jorge I

    2013-01-01

    Serum albumin levels have been used to evaluate the severity of the burns and the nutrition protein status in burn people, specifically in the response of the burn patient to the nutrition. Although it hasn't been proven if all these associations are fully funded. The aim of this retrospective study was to determine the relationship of serum albumin levels at 3-7 days after the burn injury, with the total body surface area burned (TBSA), the length of hospital stay (LHS) and the initiation of the oral/enteral nutrition (IOEN). It was carried out with the health records of patients that accomplished the inclusion criteria and were admitted to the burn units at the University Hospital of Reina Sofia (Córdoba, Spain) and UAB Hospital at Birmingham (Alabama, USA) over a 10 years period, between January 2000 and December 2009. We studied the statistical association of serum albumin levels with the TBSA, LHS and IOEN by ANOVA one way test. The confidence interval chosen for statistical differences was 95%. Duncan's test was used to determine the number of statistically significantly groups. Were expressed as mean±standard deviation. We found serum albumin levels association with TBSA and LHS, with greater to lesser serum albumin levels found associated to lesser to greater TBSA and LHS. We didn't find statistical association with IOEN. We conclude that serum albumin levels aren't a nutritional marker in burn people although they could be used as a simple clinical tool to identify the severity of the burn wounds represented by the total body surface area burned and the lenght of hospital stay.

  16. Color centers in heavily irradiated CsI(Tl) crystals

    International Nuclear Information System (INIS)

    Yakovlev, V.; Meleshko, A.; Trefilova, L.

    2008-01-01

    The absorption and luminescence properties of CsI(Tl) crystals colored by irradiation are studied by the method of the time-resolved spectroscopy. The scheme of the electron transitions in CsI(Tl) crystal is suggested to explain the appearance of the color centers under exposure to the near-UV light. It is established that either of the two types activator color centers holds the charge carrier with opposite sign. The model of the hole Tl 2+ v c - activator color center is suggested. According to the model the positive charge of Tl 2+ ion is compensated by the negative charge of a close cation vacancy v c - . The color center emission reveals in the cathode-luminescence spectrum of the colored CsI(Tl) crystal. The high-dose irradiation of CsI(Tl) crystal results in the reduction of the decay time of the near-thallium self-trapped excitons (STE) emission. The decay kinetics of Tl 2+ v c - emission contains the time components typical for the decay kinetics of near-thallium STE emission. The reason of the observed effects is the energy transfer from the near-thallium STE excitons to the color centers via the inductive-resonant mechanism

  17. Morphometric Characteristics and Length-Weight Relationship of Russian Sturgeon Juveniles Fed with Different Ratio

    Directory of Open Access Journals (Sweden)

    Raluca Cristina ANDREI(GURIENCU

    2017-11-01

    Full Text Available The aim of this paper was to analyze some morphometric characteristics and the correlation between them for Russian sturgeon juveniles (Acipenser gueldenstaedtii reared in a recirculating aquaculture system fed at different fed with different ratio: 1% body weight (BW, 1.5% BW, 2% BW and ad libitum feeding (which was around 2.8% BW.Fish, with an average body mass around 248.194 ± 1.59 g. Following biometric measurements were made for each fish, including weight (W, total length (TL, standard length (SL, fork length (FL, maximum body depth (last depth of caudal peduncle, H; preanal distance (AD, predorsal distance (PD, length of head (C, preorbital distance (PO, length of pectoral fin (LPF, interorbital distance (ID, maximum width of head (MH, width of mouth (WM, width of the head at the level of the mouth (WHM. The obtained results showed significant differences between all morphometric measurements (p<0.05 for all the experimental variants, emphasizing that in the ad libitum feeding all morphometric measurements were significantly higher than in the other experimental variants. In order to highlight more eloquent these differences, were developed some linear regressions between the morphometric measurements and significant positive correlation (p<0.05 between dependent and independent variables were found.

  18. Preparation of 199Tl and its labelled compound

    International Nuclear Information System (INIS)

    Zhou Dehai; Guan Changtian; Kuang Anren

    1991-10-01

    Usually, 199 Ti is obtained by the nuclear reaction of 197 Au(α, 2n) 199 Tl. A gold target with 50±0.1 mm in diameter, 0.8 mm in thickness and 99.99% in purity was mounted in a cyclotron beam line. The target was bombarded by α particles with the energy of 25∼27 MeV and the beam current of 15∼20μA. The irradiated gold target was dissolved by aqua regia. Then the saturated aqueous solution of SO 2 was added. The 199 Tl(III)reduced to 199 Tl(I). The deposit of gold was removed. For separation of 199 Tl)I), about 5 mL of raw material solution obtained was transferred to 201 x 8 type anion exchange resin column which had been equilibrated with 4 mol/L HCl. The 199 Tl(I) and Au(III) were desorbed separately with the eluants (90% of aqueous diamide solution,, and 2 mol/L HCL∼5% thiourea) at the flow rate of 0.25 mL/min. After separation, the 10 mL concentrated nitric acid was added to the 199 Tl collected solution to destroy and remove the aqueous diamide solution, then 4 mol/L HCl was added and heated up to remove NO 3 - . The TlCl injection with pH = 5 was made up by using physiological saline. After filtering the 199 TlCl injection was sterilized at 137.3 kPa, 120 deg C about 30 min in an autoclave. The 199 TlCl injection was used in the animal pyrogen, a bacterial, safety, dispensation and myocardial imaging experiments. The good results have been obtained. Now it has undergone clinical experiments

  19. Telomere length is highly inherited and associated with hyperactivity-impulsivity in children with attention deficit/hyperactivity disorder

    Directory of Open Access Journals (Sweden)

    Danielle Souza Costa

    2015-07-01

    Full Text Available Telomere length (TL is highly heritable, and a shorter telomere at birth may increase the risk of age-related problems. Telomere length (TL is highly heritable, and a shorter telomere at birth may increase the risk of age-related problems. Additionally, a shorter TL may represent a biomarker of chronic stress and has been associated with psychiatric disorders. However, no study has explored whether there is an association between TL and the symptoms of one of the most common neurodevelopmental disorders in childhood: Attention Deficit/Hyperactive Disorder (ADHD. We evaluated 61 (range, 6-16 years ADHD children and their parents between 2012 and 2014. Telomere length was measured with a quantitative polymerase chain reaction method with telomere signal normalized to the signal from a single copy gene (36B4 to generate a T/S ratio. Family data was processed through a GEE model to determine the effect of parental TL on children TL. Inattentive and hyperactive-impulsive symptoms were also evaluated in relation to TL. For the first time, we found general heritability to be the major mechanism explaining interindividual telomere length variation in ADHD (father-child: 95%CI=0.35/0.91, p0.05. The ADHD inattentive dimension was not significant associated with TL in this study (p>0.05. TL was shown to be a potential biomarker of the ADHD symptoms burden in families affected by this neurodevelopmental disorder. However, it is crucial that future studies investigating the rate of telomere attrition in relation to psychiatric problems to consider the strong determination of telomere length at birth by inheritance.

  20. TL Dating Technique Based on a Trap Model and its Application as a Geochronometer for Granitic Quartz

    International Nuclear Information System (INIS)

    Han, Y.; Li, H.; Tso, Y.W.

    1999-01-01

    A trap model is introduced to describe the behaviours of both thermally sensitive and radiation sensitive TL traps. The former are relatively shallow traps. The latter are deep traps, in which population increases with exposure to alpha dose. Thermal decay of both types of traps at ambient temperature is dependent on the trap lifetimes. A trap's population can be measured as TL sensitivity to a laboratory test dose. The trap model has been supported by observations of age dependent TL signals from granitic quartz samples with different crystallisation ages. The trap lifetimes are from 1.98 x 10 9 to 5.36 x 10 15 years estimated using the isothermal decay experiment with the assumption of first order kinetics. Dating techniques are proposed based on the trap model. For old granites (>400 Ma), ages can be obtained by measuring the total exposed alpha dose using the additive alpha dose method, whereas for young granites (<400 Ma), ages can also be obtained by interpolating the TL sensitivity to a curve of TL sensitivities for known ages. (author)

  1. FDG F18/Rest Tl 201 SPECT patterns in recent myocardial infarction. Predictive value for regional function recovery

    Energy Technology Data Exchange (ETDEWEB)

    Massardo, Teresa [Universidad de Chile, Hospital Clinico. Centro de Medicina Nuclear, Santiago (Chile); Gonzalez, Patricio; Coll, Claudia; Yovanovich, Jorge; Jofre, M Josefina; Humeres, Pamela; Sierralta, Paulina; Chamorro, Hernan; Ramirez, Alfredo; Kunstmann, Sonia; Lopez, Hector; Aramburu, Ivonne; Bru, Solange [Universidad de Chile, Santiago (Chile). Hospital Clinico. Centros de Medicina Nuclear e Cardiovascular; Clinica Santa Maria, Santiago [Chile

    2003-04-01

    Background: detecting viability is important after recent myocardial infarction (MI). SPECT FDG/Tl flow-metabolism patterns for predicting functional recovery were analyzed in this setting. Method: forty-one patients were studied (56+-12 years; 80% males) with Tl 201 at rest and FDG F 18 SPECT at a mean of 8.9 days post MI (range:1-24). All had baseline and 3 month follow-up echocardiography (Echo) and initial coronary angiography. They were submitted to primary PTCA in 12 cases, late PTCA in 15 and bypass surgery in 10 and thrombolysis was performed in 4 patients as only procedure. A total of 345 culprit artery territory segments were interpreted by 3 nuclear independent observers. Analysis included segments with or without abnormal motion. Results: FDG/Tl 201 on patient basis, had: sensitivity 91%; specificity 56%; positive predictive value 88 %; negative predictive value (NPV) 63% and accuracy 83%. The analysis of segments with abnormal contractility showed values of 67%, 69%, 44%, 85% and 68%, respectively. Reverse mismatch with FDG/Tl appears to predict viability similarly to classical mismatch; severe or moderate match was highly associated with no functional recovery (NPV 85%). Conclusion: flow-perfusion patterns are variable in recent MI. FDG/Tl 201 SPECT has acceptable accuracy for predicting functional recovery and excellent NPV to further exclude viability (author)

  2. FDG F18/Rest Tl 201 SPECT patterns in recent myocardial infarction. Predictive value for regional function recovery

    International Nuclear Information System (INIS)

    Massardo, Teresa; Gonzalez, Patricio; Coll, Claudia; Yovanovich, Jorge; Jofre, M. Josefina; Humeres, Pamela; Sierralta, Paulina; Chamorro, Hernan; Ramirez, Alfredo; Kunstmann, Sonia; Lopez, Hector; Aramburu, Ivonne; Bru, Solange; Clinica Santa Maria, Santiago

    2003-01-01

    Background: detecting viability is important after recent myocardial infarction (MI). SPECT FDG/Tl flow-metabolism patterns for predicting functional recovery were analyzed in this setting. Method: forty-one patients were studied (56+-12 years; 80% males) with Tl 201 at rest and FDG F 18 SPECT at a mean of 8.9 days post MI (range:1-24). All had baseline and 3 month follow-up echocardiography (Echo) and initial coronary angiography. They were submitted to primary PTCA in 12 cases, late PTCA in 15 and bypass surgery in 10 and thrombolysis was performed in 4 patients as only procedure. A total of 345 culprit artery territory segments were interpreted by 3 nuclear independent observers. Analysis included segments with or without abnormal motion. Results: FDG/Tl 201 on patient basis, had: sensitivity 91%; specificity 56%; positive predictive value 88 %; negative predictive value (NPV) 63% and accuracy 83%. The analysis of segments with abnormal contractility showed values of 67%, 69%, 44%, 85% and 68%, respectively. Reverse mismatch with FDG/Tl appears to predict viability similarly to classical mismatch; severe or moderate match was highly associated with no functional recovery (NPV 85%). Conclusion: flow-perfusion patterns are variable in recent MI. FDG/Tl 201 SPECT has acceptable accuracy for predicting functional recovery and excellent NPV to further exclude viability (author)

  3. Comparison of TL profiles in recent sea cores

    Energy Technology Data Exchange (ETDEWEB)

    Castagnoli, G C; Bonino, G

    1985-01-01

    The thermoluminescence (TL) profile of different recent Tyrrhenian sea cores sampled at various intervals during the last centuries have been compared in order to check the reproducibility of the profiles and investigate the possibility of using the results for monitoring solar-terrestrial relations in the past. The satisfactory results obtained by comparison of two different cores in the time interval 1755-1969 A.D. has demonstrated: (a) the two TL profiles are correlated; (b) the 11 yr cycle corresponding to the main solar cycle is evident in both TL profiles.

  4. Photon and neutron energy response of Thermoluminescent (TL) dosimeters

    International Nuclear Information System (INIS)

    Thilagam, L.; Priya, M.R.; Mohapatra, D.K.

    2018-01-01

    Theoretical Monte Carlo (MC) simulations are carried out to investigate the relative thermoluminesence (TL) response of the most commonly used TLD materials to a wide range of photon energy. The effect of polytetrafluoroethylene (PTFE) on TL response of CaSO 4 :Dy is also studied. Additionally, the neutron response of LiF:Mg,Ti TL materials with different concentrations of 6 Li is estimated in terms of the number of 6 Li(n, t) 4 He capture reactions for a wider neutron energy

  5. Leukocyte telomere length and personality : Associations with the big five and type d personality traits

    NARCIS (Netherlands)

    Schoormans, D.; Verhoeven, J.E.; Denollet, J.; van de Poll-Franse, L.V.; Penninx, B.W.J.H.

    2018-01-01

    Accelerated cellular ageing, which can be examined by telomere length (TL), may be an overarching mechanism underlying the association between personality and adverse health outcomes. This 6-year longitudinal study examined the relation between personality and leukocyte telomere length (LTL) across

  6. In vivo effects of radioactive properties of Tl-201 on human carbonic anhydrase activity

    Science.gov (United States)

    Sahin, Ali; Senturk, Murat

    2017-04-01

    Carbonic anhydrase (CA) is a family of metalloenzymes that requires Zn as a cofactor and catalyze the quick conversion of CO2 to HCO3- and H+. Inhibitors of the carbonic anhydrases (CAs) have medical usage of significant diseases such as glaucoma, epilepsy, gastroduodenal ulcers, acid-base disequilibria and neurological disorders. The most useful radioisotope, Tl-201, decays by electron capture, emitting Hg X-rays ( 70-80 keV), and photons of 135 and 167 keV in 10% total abundance. Therefore, it has good imaging characteristics without excessive patient radiation dose. It is the most popular isotope used for thallium 201 nuclear cardiac stress tests. In the present study, In vivo inhibitory effect of Tl-201 (Thallium-201) on human erythrocyte carbonic anhydrase (CA) activity were investigated.

  7. Solid solutions of thallium in TlGaSe2, TlGaS2, and TlInS2

    International Nuclear Information System (INIS)

    Voroshilov, Yu. V.; Potorii, M.V.; Shevchenko, S.V.

    1986-01-01

    The authors study the nature of the dissolution of thallium in ternary phases. They have synthesized alloys of the stoichiometric compositions TlGaS 2 , TlGaSe 2 , and T1InS 2 , and their solid solutions, maximally enriched in thallium, the compositions of which were Tl /SUB 1.34/ GA /SUB 0.89/ S 2 , Tl /SUB 1.31/ Ga /SUB 0.90/ Se 2 , and Tl /SUB 1.15/ In /SUB 0.95/ S /SUB 2./ . Samples were synthesized from the elemental components of the following purities: gallium of V4 grade; indium of V4 grade; thallium of T1000 grade; selenium of special purity 22-4 grade, and sulfur of special purity garde. The compositions were checked by x-ray-phase-(DRON-0.5) and microstructural-analyses with simultaneous determination of the density and microhardness of the samples. It is found that the lattic parameter increases and the increase in the density and microhardness points to strengthening of the structure during the formation of the solid solutions

  8. Improvements in the Tl dosimetry for Radiotherapy; Mejoras en la dosimetria Tl para Radioterapia

    Energy Technology Data Exchange (ETDEWEB)

    Bustos, S.; Velez, G.; Rubio, M. [CEPROCOR. Arenales 230 Juniors Cordoba 5000 (Argentina)

    1998-12-31

    The thermoluminescent dosimetry (TLD) in vivo has been demonstrated to be one of the most reliable for the control of radiotherapeutic treatments, but the delay in the response is the main disadvantage in its applicability. In this work are presented important improvements and it is demonstrated that maintaining the accuracy and reliability of the technique, it is possible to accelerate the response times at a few hours. To realize this work is utilized a lecturer Harshaw 4000, dosemeters LiF-TLD-100 chips (3.1 x 3.1 x 0.89 mm{sup 3}) and rods (1 x 1 x 6 mm{sup 3}). With the implementation of a glow curve analysis program developed in CIEMAT, its obtained a Tl peaks separation in such manner rapid and accurate, by that the thermal treatment of dosemeters may be reduced at one unique annealing pre-irradiation for 1 hr at 400 Centigrade. It is realized a periodical and individual calibration of the TLD and a study of the factors which influencing the ratio Tl signal-dose as linearity, correction by energy, directional response and pride of Tl signal. the results of this study are introducing in a calculation list specially designed and which allows to obtain absorbed dose by TLD starting of the dates (dosimetric peaks area) which appear of the glow curves analysis. The dose is obtained with an accuracy less than 5 %. The dosemeters already irradiated (in vivo) are analysed and informed in only four hours, allowing a greater control of the treatment and a correction of the possible errors for the next session, still in bi fractional treatments. The method implemented results thus accurate, rapid and reliable. (Author)

  9. Ultrashort-period lateral composition modulation in TlInGaAsN/TlInP structures

    International Nuclear Information System (INIS)

    Ishimaru, Manabu; Tanaka, Yuusuke; Hasegawa, Shigehiko; Asahi, Hajime; Sato, Kazuhisa; Konno, Toyohiko J.

    2009-01-01

    We prepared TlInGaAsN/TlInP quantum well structures using gas source molecular-beam epitaxy and characterized them by means of transmission electron microscopy and scanning transmission electron microscopy. It was found that naturally formed vertical quantum wells, so-called lateral composition modulation (LCM), with a periodicity of ∼1 nm are formed in TlInGaAsN layers. We discuss their formation process using a simple kinetic Ising model for layer-by-layer growth, and point out that the formation of ultrashort-period LCM is a universal phenomenon in most of epitaxially grown III-V semiconductor alloys.

  10. Tsygankoite, Mn8Tl8Hg2(Sb21Pb2TlΣ24S48, a New Sulfosalt from the Vorontsovskoe Gold Deposit, Northern Urals, Russia

    Directory of Open Access Journals (Sweden)

    Anatoly V. Kasatkin

    2018-05-01

    Full Text Available Tsygankoite, ideally Mn8Tl8Hg2(Sb21Pb2TlΣ24S48, is a new sulfosalt discovered at the Vorontsovskoe gold deposit, Northern Urals, Russia. It occurs as lath-like elongated crystals up to 0.2 mm embedded in calcite–dolomite–clinochlore matrix. The associated minerals also include aktashite, alabandite, arsenopyrite, barite, cinnabar, fluorapatite, orpiment, pyrite, realgar, routhierite, sphalerite, tilasite, and titanite. The new mineral is non-fluorescent, black, and opaque with a metallic lustre and black streak. It is brittle with an uneven fracture and no obvious parting and cleavage. Its Vickers hardness (VHN10 is 144 kg/mm2 (range 131–167 kg/mm2 and its calculated density is 5.450 g cm. In reflected light, tsygankoite is white; between crossed polars it is dark grey to black. It is strongly anisotropic: rotation tints vary from light grey to dark grey to black. Pleochroism and internal reflections are not observed. The chemical composition of tsygankoite (wt %, electron-microprobe data is: Mn 6.29, Hg 5.42, Tl 26.05, Pb 5.84, As 3.39, Sb 30.89, S 21.87, total 99.75. The empirical formula, calculated on the basis of 90 atoms pfu, is: Mn8.06Tl8.00Hg1.90(Sb17.87As3.19Pb1.99Tl0.97Σ24.02S48.03. Tsygankoite is monoclinic, space group C2/m, a = 21.362(4 Å, b = 3.8579(10 Å, c = 27.135(4 Å, β = 106.944(14°, V = 2139.19(17 Å3 and Z = 1. The five strongest diffraction peaks from X-ray powder pattern (listed as (d,Å(I(hkl are: 3.587(100(112, 3.353(70(−114, 3.204(88(405, 2.841(72(−513, and 2.786(99(−514. The crystal structure of tsygankoite was refined from single-crystal X-ray diffraction data to R = 0.0607 and consists of an alternation of two thick layer-like arrays, one based on PbS-archetype and the second on SnS-archetype. Tsygankoite has been approved by the IMA-CNMNC under the number 2017-088. It is named for Mikhail V. Tsyganko, a mineral collector from Severouralsk, Northern Urals, Russia, who collected the samples where the

  11. Superdeformation in the Hg-Tl-Pb region

    International Nuclear Information System (INIS)

    Henry, E.A.; Becker, J.A.; Yates, S.W.; Wang, T.F.; Kuhnert, A.; Brinkman, M.J.; Cizewski, J.A.; Deleplanque, M.A.; Diamond, R.M.; Stephens, F.S.; Azaiez, F.; Korten, W.; Draper, J.E.

    1990-10-01

    Superdeformation in the Hg-Tl-Pb region is discussed, with concentration on the experimental results. At least twenty-five superdeformed bands are known in this region, providing much new data to test theoretical calculations. 22 refs., 5 figs

  12. Use of universal functional optimisation for TL glow curve analysis

    International Nuclear Information System (INIS)

    Pernicka, F.; Linh, H.Q.

    1996-01-01

    The effective use of any TL instrument requires an efficient software package to be able to fulfil different tasks required by research and practical applications. One of the standard features of the package used at the NPI Prague is the application of the interactive modular system Universal Functional Optimisation (UFO) for glow curve deconvolution. The whole system has been tested on standard glow curves using different models of the TL process (a single peak described by the Podgorsak approximation, first order kinetics and/or general order kinetics). Calculated values of basic TL parameters (E and s) show a good agreement with the results obtained by other authors. The main advantage of the system is in its modularity that enables flexible changes in the TL model and mathematical procedures of the glow curve analysis. (author)

  13. Trace element geochemistry and thermoluminescence (TL) of quartz ...

    African Journals Online (AJOL)

    *

    3Department of Materials Science and Engineering, Tsinghua University, Beijing 100084, China. ... exposure in the recent twenty years, the TL characteristics of the fish otolith have not yet been ..... New discoveries in the study of carp otoliths.

  14. A preliminary study of landslide gouge dating by TL technique

    Energy Technology Data Exchange (ETDEWEB)

    Fengju, Ji; Jianping, Li [Inst. of Geology, National Seismological Bereau, Beijing (China); Mingda, Liu [Inst. of Crustal Dynamics, SSB, Beijing (China)

    1993-04-01

    The key to date slipping of landslide by TL method is whether the temperature and pressure caused by slipping can lead the original TL to 'zero'for some minerals within the slipping band. For this purpose, the simulated experiments under different temperature-pressure were made and the TL annealing effect of landslide gouge was studied. The results show that the frictional heating caused during slipping is a main factor leading the mineral's TL to decrease on the slip plane and that increment of temperature is in close relation with strength of shear stress, thickness of landslide gouge and amount of displacement. As an example, the slipping age of a paleo-landslide at Huangtupo, Hubei Province, has been dated to be about 140 ka.

  15. TL dating of vases with elephant ears in Yuan Dynasty

    International Nuclear Information System (INIS)

    Xia Junding; Wang Weida; Leung, P.L.

    2005-01-01

    Thermoluminescence (TL) dating using an activation method in pre-dose technique was described. Three vases in underglaze blue with elephant ears and one vase in underglaze red with elephant ears in Yuan Dynasty were dated by this method. The results show that the TL ages are all less than 100 a B.P., and in which sbc 648 and sbc 649 were imitated in recent years. This method is quick, convenient and reliable for porcelain dating with the age of less than 1000 a B.P.. As a comparison, a porcelain sample with underglaze blue in Yuan Dynasty was dated too, and its TL age is 620 ± 140 B.P.. In addition, some complex factors associated with dating have been discussed and a resolution has been raised, which will help improve the accuracy of TL dating. (authors)

  16. An in silico investigation into the causes of telomere length heterogeneity and its implications for the Hayflick limit.

    Science.gov (United States)

    Golubev, A; Khrustalev, S; Butov, A

    2003-11-21

    In telomerase-negative cell populations the mean telomere length (TL) decreases with increasing population doubling number (PD). A critically small TL is believed to stop cell proliferation at a cell-, age- and species-specific PD thus defining the Hayflick limit. However, positively skewed TL distributions are broad compared to differences between initial and final mean TL and strongly overlap at middle and late PD, which is inconsistent with a limiting role of TL. We used computer-assisted modelling to define what set of premises may account for the above. Our model incorporates the following concepts. DNA end replication problem: telomeres loose 1 shortening unit (SU) upon each cell division. Free radical-caused TL decrease: telomeres experience random events resulting in the loss of a random SU number within a remaining TL. Stochasticity of gene expression and cell differentiation: cells experience random events inducing mitoses or committing cells to proliferation arrest, the latter option requiring a specified number of mitoses to be passed. Cells whose TL reaches 1SU cannot divide. The proliferation kinetics of such virtual cells conforms to the transition probability model of cell cycle. When no committing events occur and at realistic SU estimates of the initial TL, maximal PD values far exceed the Hayflick limit observed in normal cells and are consistent with the crisis stage entered by transformed cells that have surpassed the Hayflick limit. At intermediate PD, symmetrical TL distributions are yielded. Upon introduction of committing events making the ratio of the rates of proliferating and committing events (P/C) range from 1.10 to 1.25, TL distributions at intermediate PD become positively skewed, and virtual cell clones show bimodal size distributions. At P/C as high as 1.25 the majority of virtual cells at maximal PD contain telomeres with TL>1SU. A 10% increase in P/C within the 1.10-1.25 range produces a two-fold increase in the maximal PD, which

  17. Examination of TL and optical absorption in calcite's mineral

    International Nuclear Information System (INIS)

    Sabikoglu, I.; Can, N.

    2009-01-01

    Calcite which is a form of crystalline of the calcium carbonate composes parent material of chalk stone (limestone) and marble. Calcite which presents in various colors also in our country consists of yellow, blue, transparent and green colors. In this study, green calcite mineral which is taken from the region of Ayvalik, was examined of its thermoluminescence (TL) and optical absorption features in different doses. It has been obtained a large TL peak in 179 degree C and absorption peak in 550 mm.

  18. Deformation effects in electronic spectra of the layered semiconductors TlGaS sub 2 , TlGaSe sub 2 and TlInS sub 2

    CERN Document Server

    Allakhverdiev, K R; Suleymanov, R A; Gasanov, N Z

    2003-01-01

    The deformation effects in electronic spectra of the ternary layered semiconductors TlGaS sub 2 , TlGaSe sub 2 and TlInS sub 2 are considered. It is shown that the influence of hydrostatic pressure, thermal expansion and variation of composition in solid solutions on the band gap of the crystals investigated can be described in the framework of one common model of deformation potentials. This model appears to be close to that of layered semiconductors of the A sub 3 B sub 6 group, attesting to the fact that the main principles of formation of band structure in these two groups of layered crystals are the same.

  19. TL1A regulates TCRγδ+ intraepithelial lymphocytes and gut microbial composition

    DEFF Research Database (Denmark)

    Tougaard, Peter; Skov, S.; Pedersen, A. E.

    2015-01-01

    TL1A is a proinflammatory cytokine, which is prevalent in the gut. High TL1A concentrations are present in patients with inflammatory bowel disease (IBD) and in IBD mouse models. However, the role of TL1A during steady‐state conditions is relatively unknown. Here, we used TL1A knockout (KO) mice ...

  20. Natural quartz TL property and similarity in Piper nigrum L

    International Nuclear Information System (INIS)

    Guzman A, S.; Cruz Z, E.; Furetta, C.; Brown, F.; Barboza F, M.

    2009-10-01

    Quartz is a mineral abundant in nature and can provide information thermoluminescent (TL), and also is located in the mineral fraction of some herbs and spices consumed. It is present the analysis of the TL properties of a sample of natural quartz rock and compared with those obtained from the fraction of Piper nigrum L. poly mineral when they were exposed to 60 Co gamma radiation. The poly minerals of Piper nigrum L. were analyzed by X-ray diffraction, where the quartz was found as a major component. They separated in different particle sizes (10, 53, 74 and 149 μm). The samples were irradiated at relatively low doses (1-500 Gy) and high (0.1-40 kGy) in order to determine the linearity of the TL emission as a function of the dose and the analysis of glow curves. Also there was the fading of the TL signal, the effect of ultra violet light. The reproducibility of the TL signal in the samples indicates that a smaller particle size gives better TL signal. (author)

  1. TL response of citrine samples for high-dose dosimetry

    International Nuclear Information System (INIS)

    Teixeira, Maria Ines; Caldas, Linda V.E.

    2011-01-01

    The possibility of using samples of Brazilian stones as quartz, amethyst, topaz, etc. for high-dose dosimetry has been studied in recent years at IPEN, using the thermoluminescence technique (TL). In this work, the TL properties of citrine samples were studied. They were exposed to different doses of gamma radiation ( 60 Co). The natural citrine stone was extracted from a mine in Minas Gerais state, Brazil; it is a tectosilicate ranked as one of three-dimensional structure, showing clear yellow to golden brown color. The natural citrine stone is classified as quartz (SiO 2 ), and it has a lower symmetry and more compact reticulum. The citrine stone samples were powdered, and the selected grains were mixed with Teflon in the proportion 2 (Teflon):1 (Citrine). The mixture was pressed and sintered for production of Citrine -Teflon pellets of 50 mg. The TL emission curve showed two peaks at 160 deg C and 220 deg C. To remove the TL peak (160 deg C) of the sintered citrine pellet glow curves, different thermal treatments were tested during several time intervals. The TL dose-response curve between 50 Gy and 100 kGy, the reproducibility of TL response and the lower detection dose were obtained. The preliminary results show that citrine may be useful for high-dose dosimetry. (author)

  2. Remote TL and OSL for asteroid and meteorite study

    International Nuclear Information System (INIS)

    Takaki, Shunji; Ikeya, Motoji; Yamanaka, Chihiro

    1997-01-01

    Thermoluminescence (TL) and optically stimulated luminescence (OSL) of the Allende meteorite have been studied using infrared CO 2 laser light as a heat source and He-Ne laser light to excite the material, respectively from a long distance. New techniques of remote TL (R-TL) and remote OSL (R-OSL) have been developed for future remote dating from a long distance in a planetary survey. The upper limits of the distance for R-TL and R-OSL were estimated using the laboratory TL signal of the meteorite peaking at 320 o C: about 400 photons s -1 for the R-TL and 60 photons s -1 for R-OSL at a distance of 1 km using a laser beam with the divergence of 0.1 mrad at powers of 100 and 1 W, respectively. An age limit of 10 5 or 10 6 years due to the signal saturation and the objects heterogeneity, as expected from previous studies, may make the asteroid survey difficult but would still help to investigate the surface activities of icy planets and satellites in outer planet worlds. (author)

  3. Leg 201Tl-SPECT in chronic exertional compartment syndrome

    International Nuclear Information System (INIS)

    Elkadri, N.; Slim, I.; Blondet, C.; Choquet, Ph.; Constantinesco, A.; Lecocq, J.

    2004-01-01

    Leg 201 Tl-SPECT in chronic exertional compartment syndrome Background: The chronic exertional compartment syndrome is one of the most frequent origins regarding leg pain due to sport training. The diagnosis can be established by invasive compartment pressure measurement. The aim of this study is to evaluate the role that could have 201 Tl-SPECT for patients with suspicion of compartment syndrome. Patients and methods: 51 leg 201 Tl-SPECT exams were performed (exercise - and rest without reinjection) in 49 patients; 28 had compartment syndrome confirmed by pressure measurement. About 100 MBq of 201 Tl were injected during exercise, when pain appeared or at least after 25 minutes exercise. We studied mean percentages of level uptake for each compartment, referred to the maximal uptake of both legs. Results: 47 compartments were concerned by compartment syndrome and 361 compartments were not. Scintigraphic patterns in compartments are reversible ischaemia (45%), uptake stability (36%) or reverse redistribution (19%); these patterns are not linked to compartment syndrome. However, there is a significant difference of rest 201 Tl level uptake between compartments with and without compartment syndrome and a significant correlation between muscular pressure measurement and rest level uptake. Conclusion: 201 Tl-SPECT shows that only ischaemia does not explain compartment syndrome. Moreover, it allows to predict pressure variation during exercise but it does not offer any interest in order to select patients for muscular invasive pressure measurement. (author)

  4. $\\alpha$-decay study of $^{182,184}$Tl

    CERN Document Server

    Van Beveren, C; Barzakh, A E; Cocolios, T E; de Groote, R P; Fedorov, D; Fedosseev, V N; Ferrer, R; Ghys, L; Huyse, M; Köster, U; Lane, J; Liberati, V; Lynch, K M; Marsh, B A; Molkanov, P L; Procter, T J; Rapisarda, E; Sandhu, K; Seliverstov, M D; Van Duppen, P; Venhart, M; Veselský, M

    2016-01-01

    α -decay spectroscopy of 182,184 Tl has been performed at the CERN isotope separator on-line ( ISOLDE ) facility. New fi ne-structure α decays have been observed for both isotopes. α -decay branching ratios of 0.089 ( 19 ) %, 0.047 ( 6 ) % and 1.22 ( 30 ) % have been deduced for the ( 10 − ) , ( 7 + ) and ( 2 − ) states respectively in 184 Tl and a lower limit of 0.49% for the α -decay branching ratio of 182 Tl. A new half-life of 9.5 ( 2 ) s for the ( 2 − ) state in 184 Tl and 1.9 ( 1 ) s for the low-spin state in 182 Tl has been deduced. Using α – γ coincidence analysis, multiple γ rays were observed de-exciting levels in 178,18 0 Au fed by 182,184 Tl α decays. The γ transitions connecting these low-lying states in 178,18 0 Au are essential to sort the data and possibly identify bands from in- beam studies in these isotopes. Owing to the complex fi ne-structure α decays and limited knowledge about the structure of the daughter nuclei, only partial level schemes could be constructed for bot...

  5. Value of 201Tl imaging in predicting therapeutic 131I uptake in patients with thyroglobulin-positive but 131I scan-negative differentiated thyroid carcinoma

    International Nuclear Information System (INIS)

    Conlu, R.A.O.; Obaldo, J.M.

    2004-01-01

    Background: Serum thyroglobulin assay and 131Iodine (1311) whole body scan are considered complementary in detecting malignant thyroid tissue or metastases. A large number of patients, however, are encountered presenting with scan-negative, thyroglobulin-positive differentiated thyroid carcinoma posing a dilemma in therapeutic management. One of the first alternative scanning agents to be employed is 201Thallium (201Tl). Recent studies have demonstrated its usefulness in identifying lesions that are not visualized with traditional 131I whole body scan. It is not clear, however, whether 201Tl scan helps in the decision-making for subsequent 131I therapy. This study was conducted to determine if 201Tl scan can predict therapeutic 131I uptake and to define the clinical role of 201Tl scanning in these patients. Methods and results: A total of 12 patients (20-63 y/o), 5 males and 7 females, underwent surgery for differentiated thyroid cancer and all had serum thyroglobulin values above 10 ng/ml and normal TPO autoantibodies. Pre-therapy 131I scan using 111 MBq (3mCi) of 131I were obtained. As required for inclusion, all patients had negative pre-therapy scan and negative TPO autoantibody results and underwent 20lTl scanning within 3 weeks. All patients were given 131I therapy (3.7-5.5 GBq or 100-150 mCi) between one to two months after 201Tl scanning. Within a week after therapy, all patients underwent whole body 1311 scanning. 201Tl imaging demonstrated thyroid remnants in 9 out of 12 patients having positive 201Tl scan but negative pre-therapy 1311 scan. However, only 2 of the positive 201Tl scans showed 131I uptake post-therapy (positive predictive value of 20%). None of the subjects presented with a negative 201Tl scan and a positive post-therapy 131I scan. Conclusion: Our study suggests that evidence of remnants or metastases on 201Tl scanning may be an inappropriate basis for the decision to proceed with 131I therapy. The role of 20lTl imaging in this subset of

  6. Application of TL dosimetry in epidemiological studies in HBRAs

    International Nuclear Information System (INIS)

    Chougaonkar, M.P.

    2006-01-01

    Luminescence as a phenomenon has been extensively used in radiation dosimetry, using thermoluminescence. The nuclear industry all over the world over uses TL dosimetry in radiation protection since they have to ensure that the radiation workers and workers involved in industrial applications of radiation sources are not exposed beyond limits set by international monitoring bodies. They have also to ensure that the nuclear applications do not give rise to elevated radiation levels in the environs. In addition, epidemiologists and radiobiologists world over have been working over the past few decades, to study health effects of chronic radiation exposures in populations living in the elevated natural radiation environment. This paper discusses the importance of dosimetric studies, in the normal as well as high background radiation areas (HBRAs), due to the radiation effects on the humans. The application of thermoluminescent dosimeters (TLDs) in population dosimetry with the end point of epidemiological studies is then discussed. The paper outlines the construction of TLDs, methodology of deployment and retrieval and analysis to arrive the dose. To obtain total dose, dosimetric techniques suitable for external gamma radiation, inhalation dose due to radon, thoron and their progenies and radiological analysis of the food items is required. The techniques arriving at the effective dose are outlined. Basics of epidemiological analysis, particularly using case-control methodology and its advantages/ disadvantages are also discussed. Using the previous work by the author, the paper also reviews various analyses that can be carried out the dosimetric data. (author)

  7. Race-Ethnicity, Poverty, Urban Stressors, and Telomere Length in a Detroit Community-based Sample.

    Science.gov (United States)

    Geronimus, Arline T; Pearson, Jay A; Linnenbringer, Erin; Schulz, Amy J; Reyes, Angela G; Epel, Elissa S; Lin, Jue; Blackburn, Elizabeth H

    2015-06-01

    Residents of distressed urban areas suffer early aging-related disease and excess mortality. Using a community-based participatory research approach in a collaboration between social researchers and cellular biologists, we collected a unique data set of 239 black, white, or Mexican adults from a stratified, multistage probability sample of three Detroit neighborhoods. We drew venous blood and measured telomere length (TL), an indicator of stress-mediated biological aging, linking respondents' TL to their community survey responses. We regressed TL on socioeconomic, psychosocial, neighborhood, and behavioral stressors, hypothesizing and finding an interaction between poverty and racial-ethnic group. Poor whites had shorter TL than nonpoor whites; poor and nonpoor blacks had equivalent TL; and poor Mexicans had longer TL than nonpoor Mexicans. Findings suggest unobserved heterogeneity bias is an important threat to the validity of estimates of TL differences by race-ethnicity. They point to health impacts of social identity as contingent, the products of structurally rooted biopsychosocial processes. © American Sociological Association 2015.

  8. Tl, Bi, and Pb doping in Ba4BiPb2TlO12-δ

    International Nuclear Information System (INIS)

    Sutto, T.E.; Averill, B.A.

    1992-01-01

    To determine the effects of different 6s metal concentrations on the superconducting nature of Ba 4 BiPb 2 TlO 12-δ , materials produced via four doping schemes were examined: Ba 4 Bi(Pb, Tl) 3 O 12-δ , Ba 4 -(BiPb) 3 TlO 12-δ , Ba 4 (Bi,Tl) 2 Pb 2 O 12-δ , and Ba 4 Bi x Pb 4-2x Tl x O 12-δ . For the parent compound a value of δ = 0.91 was observed, indicating that approximately 1/4 oxygen atom was missing per cubic subsection of the unit cell. For all samples, the symmetry of the parent compound changed from orthorhombic to tetragonal as the system moved away from the ideal composition. This was usually accompanied by the loss of superconductivity, which exhibited a maximum T c of 10.5 K for the parent compound Ba 4 BiPb 2 TlO 12-δ . Also reported are high-temperature magnetic susceptibility results, which are used to determine the effect of metal substitution on the density of states at the Fermi level. For each set of variants on the parent composition, the onset of superconductivity was accompanied by a significant decrease in the size of the Pauli paramagnetic signal. 16 refs., 6 figs

  9. Father Loss and Child Telomere Length.

    Science.gov (United States)

    Mitchell, Colter; McLanahan, Sara; Schneper, Lisa; Garfinkel, Irv; Brooks-Gunn, Jeanne; Notterman, Daniel

    2017-08-01

    Father loss during childhood has negative health and behavioral consequences, but the biological consequences are unknown. Our goal was to examine how father loss (because of separation and/or divorce, death, or incarceration) is associated with cellular function as estimated by telomere length. Data come from the 9-year follow-up of the Fragile Families and Child Wellbeing Study, a birth cohort study of children in 20 large American cities ( N = 2420). Principal measures are as follows: salivary telomere length (sTL), mother reports of father loss, and polymorphisms in genes related to serotonergic and dopaminergic signaling. At 9 years of age, children with father loss have significantly shorter telomeres (14% reduction). Paternal death has the largest association (16%), followed by incarceration (10%), and separation and/or divorce (6%). Changes in income partially mediate these associations (95% mediation for separation and/or divorce, 30% for incarceration, and 25% for death). Effects are 40% greater for boys and 90% greater for children with the most reactive alleles of the serotonin transporter genes when compared with those with the least reactive alleles. No differences were found by age at father loss or a child's race/ethnicity. Father loss has a significant association with children's sTL, with the death of a father showing the largest effect. Income loss explains most of the association between child sTL and separation and/or divorce but much less of the association with incarceration or death. This underscores the important role of fathers in the care and development of children and supplements evidence of the strong negative effects of parental incarceration. Copyright © 2017 by the American Academy of Pediatrics.

  10. Analysis of metabolic change by Tl-201 SPECT in brain tumors treated with stereotactic radiosurgery

    Energy Technology Data Exchange (ETDEWEB)

    Sugo, Nobuo [Toho Univ., Tokyo (Japan). School of Medicine

    1996-03-01

    The time course for changes in Tl-201 uptake and tumor size was studied correlatively. A total of 24 cases of brain tumors was enrolled in the study. Three detector type scanner, PRISM 3000 was used. SPECT scanning was started 10 min after intravenous administration of 111 MBq of Tl-201, and sequentially repeated every 1 min for 16 min. Tl-201 radioactivity was counted in two regions of interest (ROI). One was an area encircling the tumor, and the other, an area in the contralateral hemisphere that served as control. Tl index (TI) was calculated by this formula: TI=T-C/C, where T is the count in the tumor and C, the count in the control area. The size of a given tumor was represented by its maximum diameter as determined by CT or MRI. The TI and the tumor size were compared before and after radiosurgery. In all cases, a decrease in TI was seen earlier than a reduction in tumor size. Among malignant tumors, the TI decrease took place as early as one week, and rapidly reached the lowest level. On the other hand, in benign tumors, it took as long as 6 to 12 months for the decrease of the TI to be evident; the subsequent was very slow. The difference between malignant and benign tumors of the brain is attributed to the fact that high dose irradiation of the malignant, radiosensitive tumors causes deep disturbances in cell metabolism that lead to cell death. By contrast, irradiation of a benign tumor with low radiosensitivity does not affect the cellular metabolism, but injures the vascular wall, leading to gradual stenosis or obliteration of the vessels in the tumor. These data strongly suggest that the rapid and marked decrease of malignant tumors after stereotactic radiosurgery is the result of a direct injury to the malignant cells, and that the rather slow and insufficient diminution of benign tumors can be attributed to diminished blood supply to the tumor. (author)

  11. Acculturation Predicts Negative Affect and Shortened Telomere Length.

    Science.gov (United States)

    Ruiz, R Jeanne; Trzeciakowski, Jerome; Moore, Tiffany; Ayers, Kimberly S; Pickler, Rita H

    2016-10-12

    Chronic stress may accelerate cellular aging. Telomeres, protective "caps" at the end of chromosomes, modulate cellular aging and may be good biomarkers for the effects of chronic stress, including that associated with acculturation. The purpose of this analysis was to examine telomere length (TL) in acculturating Hispanic Mexican American women and to determine the associations among TL, acculturation, and psychological factors. As part of a larger cross-sectional study of 516 pregnant Hispanic Mexican American women, we analyzed DNA in blood samples (N = 56) collected at 22-24 weeks gestation for TL as an exploratory measure using monochrome multiplex quantitative telomere polymerase chain reaction (PCR). We measured acculturation with the Acculturation Rating Scale for Mexican Americans, depression with the Beck Depression Inventory, discrimination with the Experiences of Discrimination Scale, and stress with the Perceived Stress Scale. TL was negatively moderately correlated with two variables of acculturation: Anglo orientation and greater acculturation-level scores. We combined these scores for a latent variable, acculturation, and we combined depression, stress, and discrimination scores in another latent variable, "negative affectivity." Acculturation and negative affectivity were bidirectionally correlated. Acculturation significantly negatively predicted TL. Using structural equation modeling, we found the model had an excellent fit with the root mean square error of approximation estimate = .0001, comparative fit index = 1.0, Tucker-Lewis index = 1.0, and standardized root mean square residual = .05. The negative effects of acculturation on the health of Hispanic women have been previously demonstrated. Findings from this analysis suggest a link between acculturation and TL, which may indicate accelerated cellular aging associated with overall poor health outcomes. © The Author(s) 2016.

  12. Myocardial viability assessed by Tl-201 SPECT. Redistribution versus reinjection

    International Nuclear Information System (INIS)

    Chalela, William Azem; Pimentel, Flavio Ferrarini de Oliveira; Uchida, Augusto Hiroshi; Bottega, Augusto; Ramires, Jose Antonio Franchine; Izaki, Marisa; Moraes, Aguinaldo Pereira; Soares Junior, Jose; Giorgi, Maria C. Pinto; Moffa, Paulo Jorge; Bellotti, Giovanni; Giovanni Guido Cerri; Meneghetti, Jose Claudio

    1994-01-01

    The purpose of this study was to verify if a third series of images acquired by reinjection thallium-201, 24 h after conventional myocardial perfusion with the radioisotope, improves the identification of myocardial viability segments. The methods: we studied 30 patients, mean age 57.7 ±9.4 years, with old myocardial infarction using thallium (Tl)-201 SPECT, and we obtained three series of images (stress, redistribution after 4 h and reinjection after 24 h. Cardiac images were divided in 5 segments (apical, lateral, anterior, septal and inferior) and each one received a value by a score system according to the Tl-201 myocardial uptake (0=normal uptake; 1=mild hypoperfusion; 2=moderate hypoperfusion; 3=severe hypoperfusion or no myocardial uptake). We considered viable myocardium when the uptake of Tl-201 in the segment related to te myocardial infarction increases at least 1 point in two different axis of Tl-201 SPECT. The results: seven (23,3%) patients demonstrated increase of Tl-201 uptake only at reinjection images, showing a high efficacy of the method. Nine (30%) patients showed persistent hypoperfusion at all series of images suggesting only fibrosis in the are related to the infarction. Fourteen (46,7%) patients showed increase of Tl-201 concentration at redistribution images; among these patients, six showed improvement of myocardial uptake at reinjection. This condition was interpreted as regional chronic ischemic process: hibernating myocardium. The conclusion was that Tl-201 hypoperfusion at redistribution images without significant changes in relation to the stress images do not represent fibrosis at all. The reinjection technic was better than conventional redistribution in the detection of viable myocardium. This data allows a better therapeutic orientation. (author)

  13. Development of tailor-made silica fibres for TL dosimetry

    International Nuclear Information System (INIS)

    Bradley, D.A.; Abdul Sani, Siti F.; Alalawi, Amani I.; Jafari, S.M.; Noor, Noramaliza M.; Hairul Azhar, A.R.; Mahdiraji, Ghafour Amouzad; Tamchek, Nizam; Ghosh, S.; Paul, M.C.; Alzimami, Khalid S.; Nisbet, A.; Maah, M.J.

    2014-01-01

    The Ge dopant in commercially available silica optical fibres gives rise to appreciable thermoluminscence (TL), weight-for-weight offering sensitivity to MV X-rays several times that of the LiF dosimeter TLD100. The response of these fibres to UV radiation, X-rays, electrons, protons, neutrons and alpha particles, with doses from a fraction of 1 Gy up to 10 kGy, have stimulated further investigation of the magnitude of the TL signal for intrinsic and doped SiO 2 fibres. We represent a consortium effort between Malaysian partners and the University of Surrey, aimed at production of silica fibres with specific TL dosimetry applications, utilizing modified chemical vapour deposition (MCVD) doped silica–glass production and fibre-pulling facilities. The work is informed by defect and dopant concentration and various production dependences including pulling parameters such as temperature, speed and tension; the fibres also provide for spatial resolutions down to <10 µm, confronting many limitations faced in use of conventional (TL) dosimetry. Early results are shown for high spatial resolution (∼0.1 mm) single-core Ge-doped TL sensors, suited to radiotherapy applications. Preliminary results are also shown for undoped flat optical fibres of mm dimensions and Ge-B doped flat optical fibres of sub-mm dimensions, with potential for measurement of doses in medical diagnostic applications. - Highlights: • Optical fibres tailor-made for TL dosimetry. • Sensitive to diagnostic as well as therapy doses in medicine. • Preform and fibre pulling facilities. • Relative TL and EPR measurements

  14. Lifecourse Adversity and Telomere Length in Older Women from Northeast Brazil.

    Science.gov (United States)

    Oliveira, Bruna Silva; Zunzunegui, Maria Victoria; Quinlan, Jacklyn; Batistuzzo de Medeiros, Silvia Regina; Thomasini, Ronaldo Luis; Guerra, Ricardo Oliveira

    2017-06-19

    We examined associations between adverse childhood experiences (ACEs) and shorter telomere length (TL) in 83 older women, including 42 women with less than secondary education and 41 with secondary or more education in a city of Northeast Brazil, a region with substantial socioeconomic inequalities. The low education sample was selected from a representative survey at local neighborhood health centers, while the high education group consisted of a convenience sample recruited by advertising in community centers and centers affiliated with the local university. Relative leukocyte TL was measured by quantitative polymerase chain reaction from blood samples. ACEs were self-reported. Spline linear regression was fitted to assess the strength of the associations between ACEs and TL. Among women with low education, median TL was 1.02 compared with 0.64 in the high education group (p = 0.0001). Natural log-transformed T/S ratio as the dependent variable was used in analysis. Women with low education had been exposed to more ACEs, and among them those experiencing two or more ACEs had longer TL than women exposed to ≤1 ACEs (p = 0.03); among women with high education, this difference was not significant (p = 0.49). In analyses adjusted by age, education, and parental abuse of alcohol, the linear trend of higher TL with increasing ACEs was confirmed (p = 0.02), and the mean difference in TL between groups remained significant (p = 0.002). The unexpected positive relationship between low education and ACEs with TL suggests that older adults who have survived harsh conditions prevailing in Northeast Brazil have the longest TL of their birth cohort.

  15. 201Tl/99mTc-MIBI SPECT to evaluate therapy effect of BNCT with BSH and BPA for malignant brain tumor

    International Nuclear Information System (INIS)

    Shibata, Yasushi; Katayama, Wataru; Yamamoto, Tetsuya; Nakai, Kei; Endo, Kiyoshi; Matsuda, Masahide; Matsushita, Akira; Matsumura, Akira

    2006-01-01

    201 Tl/ 99m Tc-MIBI SPECT are imaging modalities to evaluate the malignancy and viability of brain tumor. We reviewed these SPECT findings before and after BNCT, and evaluated the usefulness of SPECT. The study includes total 11 patients admitted in our hospital between 1999 and 2005, 8 with glioblastoma, 2 with anaplastic astrocytoma and 2 with anaplastic oligodendroglioma. SPECT was taken with multidetector SPECT at 15 minutes and 3 hours after intravenous injection of Tl 74 MBq or MIBI 740 MBq. Region of interests were set on tumor and contralateral white matter and radioactivity ratios were calculated as Tl, MIBI indexes. For patients with no residual tumor in MRI, Tl/MIBI indexes were low. For patients with large residual tumor the indexes were high. For the patients with recurrent tumor the indexes were very high. Tl/MIBI indexes before BNCT correlated with survival and progression-free period after BNCT. SPECT indexes decreased after BNCT. For 8 patients with recurrent tumor, the indexes increased. Tl and MIBI SPECT are valuable to evaluate malignancy, viability, survival and recurrence of malignant glioma in BNCT. (author)

  16. Synthesis, structural, X-ray photoelectron spectroscopy (XPS) studies and IR induced anisotropy of Tl{sub 4}HgI{sub 6} single crystals

    Energy Technology Data Exchange (ETDEWEB)

    Parasyuk, O.V. [Department of Inorganic and Physical Chemistry, Lesya Ukrainka Eastern European National University, Voli Ave. 13, Lutsk, 43025 (Ukraine); Khyzhun, O.Y. [Frantsevych Institute for Problems of Materials Science, National Academy of Sciences of Ukraine, 3 Krzhyzhanivsky St., 03142, Kyiv (Ukraine); Piasecki, M. [Institute of Physics, J. Dlugosz University Częstochowa, Armii Krajowej 13/15, Częstochowa (Poland); Kityk, I.V., E-mail: iwank74@gmail.com [Electrical Engineering Department, Czestochowa University Technology, Armii Krajowej 17, PL-42-217, Czestochowa (Poland); Lakshminarayana, G. [Wireless and Photonic Networks Research Centre, Faculty of Engineering, Universiti Putra Malaysia, 43400, Serdang, Selangor (Malaysia); Luzhnyi, I. [Frantsevych Institute for Problems of Materials Science, National Academy of Sciences of Ukraine, 3 Krzhyzhanivsky St., 03142, Kyiv (Ukraine); Fochuk, P.M. [Yuriy Fed’kovych Chernivtsi National University, 2 Kotziubynskoho Str., 58012, Chernivtsi (Ukraine); Fedorchuk, A.O. [Department of Inorganic and Organic Chemistry, Lviv National University of Veterinary Medicine and Biotechnologies, Pekarska Street 50, 79010, Lviv (Ukraine); Levkovets, S.I.; Yurchenko, O.M.; Piskach, L.V. [Department of Inorganic and Physical Chemistry, Lesya Ukrainka Eastern European National University, Voli Ave. 13, Lutsk, 43025 (Ukraine)

    2017-02-01

    In the present work, we report on the synthesis and structural properties including X-ray protoelectron spectroscopy (XPS) analysis of Tl{sub 4}HgI{sub 6} crystals that were grown by Bridgman-Stockbarger method up to 80 mm in length and 18 mm in diameter. The existence of the ternary compound Tl{sub 4}HgI{sub 6} that melts incongruently at 641 K was confirmed. Phase equilibria and structural properties for the TlI–HgI{sub 2} system were investigated by differential thermal analysis (DTA) and X-ray diffraction (XRD) methods. X-ray photoelectron spectra were measured for both pristine and Ar{sup +} ion-bombarded Tl{sub 4}HgI{sub 6} single crystal surfaces. The data reveal that the Tl{sub 4}HgI{sub 6} single crystal is sensitive with respect to Ar{sup +} ion-bombardment as 3.0 keV Ar{sup +} irradiation over 5 min at an ion current density 14 μA/cm{sup 2} induces changes to the elemental stoichiometry of the Tl{sub 4}HgI{sub 6} surface, leading to a decrease of the mercury content in the topmost surface layers. X-ray photoelectron spectroscopy (XPS) measurements indicate very low hygroscopic nature of the Tl{sub 4}HgI{sub 6} single crystal surface. The IR coherent bicolor laser treatment at wavelengths 10.6/5.3 μm has shown an occurrence of anisotropy at wavelengths 1540 nm of Er:glass laser. This may open the applications of Tl{sub 4}HgI{sub 6} as a material for IR laser triggering. - Highlights: • Phase diagram of the HgI{sub 2}–TlI system was built. • Tl{sub 4}HgI{sub 6} single crystals were grown by Bridgman Stockbarger method. • XRD, XPS analysis was done. • Ir induced anisotropy was established. • The compounds may be proposed as Ir laser operated polarizers.

  17. Benchmarking NaI(Tl) Electron Energy Resolution Measurements

    International Nuclear Information System (INIS)

    Mengesha, Wondwosen; Valentine, J D.

    2002-01-01

    A technique for validating electron energy resolution results measured using the modified Compton coincidence technique (MCCT) has been developed. This technique relies on comparing measured gamma-ray energy resolution with calculated values that were determined using the measured electron energy resolution results. These gamma-ray energy resolution calculations were based on Monte Carlo photon transport simulations, the measured NaI(Tl) electron response, a simplified cascade sequence, and the measured electron energy resolution results. To demonstrate this technique, MCCT-measured NaI(Tl) electron energy resolution results were used along with measured gamma-ray energy resolution results from the same NaI(Tl) crystal. Agreement to within 5% was observed for all energies considered between the calculated and measured gamma-ray energy resolution results for the NaI(Tl) crystal characterized. The calculated gamma-ray energy resolution results were also compared with previously published gamma-ray energy resolution measurements with good agreement (<10%). In addition to describing the validation technique that was developed in this study and the results, a brief review of the electron energy resolution measurements made using the MCCT is provided. Based on the results of this study, it is believed that the MCCT-measured electron energy resolution results are reliable. Thus, the MCCT and this validation technique can be used in the future to characterize the electron energy resolution of other scintillators and to determine NaI(Tl) intrinsic energy resolution

  18. Phytotoxicity of thallium (Tl) in culture solution. Pt. 2. Effects of Tl(III) on the growth and heavy metal contents of pea and field bean plants

    Energy Technology Data Exchange (ETDEWEB)

    Pieper, B; Austenfeld, F A

    1985-01-01

    The effects of Tl(NO/sub 3/)/sub 3/ and Tl(III)EDTA on growth and heavy metal contents of pea plants and field bean plants were compared in hydroponic culture experiments. In the presence of Tl(NO/sub 3/)/sub 3/, the essential heavy metals were available to the plants in their ionic forms. When Tl(III)EDTA was present the essential heavy metals were available as chelated complexes. Dry matter production of the pea plants was inhibited to a greater extent by Tl(III)EDTA than by Tl(NO/sub 3/)/sub 3/. The distribution of Tl within the plant was unaffected by the accompanying anion, however an increase of the Tl content of the stems and the leaves was observed in the presence of Tl(III)EDTA. The micronutrients exhibited different interactions with Tl(III). In the presence of increasing concentrations of Tl(NO/sub 3/)/sub 3/ the Mn content of each organ and the Zn content of the roots were lowered, but the Zn content of the stems was increased. Increasing concentrations of Tl(III)EDTA resulted only in a decrease of the Mn content of the roots, but in an increase of the contents of Fe and Mn within the stems, and Fe, Mn, Zn, and Cu within the leaves. The increases may be due to concentration by growth inhibition. In contrast to pea plants, growth of field bean plants was inhibited only by Tl(NO/sub 3/)/sub 3/. The field bean plants retained most of the Tl within the roots independent of the Tl compound in the solution. Chelation of Tl(III) resulted in higher Tl contents of both the roots and the stems, but equal or reduced Tl contents of the leaves. Whereas increasing concentrations of Tl(NO/sub 3/)/sub 3/ reduced the Mn content of each organ as well as the Zn content of the roots and the leaves, Tl(III)EDTA only reduced the Mn content of the roots.

  19. Ab initio calculations of the electron spectrum and density of states of TlFeS{sub 2} and TlFeSe{sub 2} crystals

    Energy Technology Data Exchange (ETDEWEB)

    Ismayilova, N. A., E-mail: ismayilova-narmin-84@mail.ru; Orudjev, H. S.; Jabarov, S. H. [Azerbaijan National Academy of Sciences, Institute of Physics (Azerbaijan)

    2017-04-15

    The results of ab initio calculations of the electron spectrum of TlFeS{sub 2} and TlFeSe{sub 2} crystals in the antiferromagnetic phase are reported. Calculations are carried out in the context of the density functional theory. The origin of the bands of s, p, and d electron states of Tl, Fe, S, and Se atoms is studied. It is established that, in the antiferromagnetic phase, the crystals possess semiconductor properties. The band gaps are found to be 0.05 and 0.34 eV for TlFeS{sub 2} and TlFeSe{sub 2} crystals, respectively.

  20. EPR and TL correlation in some powdered Greek white marbles

    International Nuclear Information System (INIS)

    Baieetto, Vanessa; Villeneuve, Gerard; Guibert, Pierre; Schvoerer, Max

    2000-01-01

    Thermoluminescence of white powdered marble samples, chosen to display different EPR spectra, were studied. Two peaks at 280 deg. C and 360 deg. C can be observed among the TL glow curves while the EPR spectra exhibit two signals: the A signal with g perp =2.0038 and g par =2.0024 due to the SO - 3 centre and the B one with g 1 =2.0005; g 2 =2.0001; g 3 =1.9998 due to mechanical powder reduction (drilling). Owing to heating and simultaneous experiments, a correlation have been established: the 280 deg. C TL peak is associated to the A signal and thus to the SO - 3 centre and the 360 deg. C TL peak is caused by mechanical treatment corresponding to the B EPR signal

  1. EPR and TL correlation in some powdered Greek white marbles

    Energy Technology Data Exchange (ETDEWEB)

    Baieetto, Vanessa E-mail: crpaa@montaigne.u-bordeaux.fr; Villeneuve, Gerard; Guibert, Pierre; Schvoerer, Max

    2000-02-01

    Thermoluminescence of white powdered marble samples, chosen to display different EPR spectra, were studied. Two peaks at 280 deg. C and 360 deg. C can be observed among the TL glow curves while the EPR spectra exhibit two signals: the A signal with g{sub perp}=2.0038 and g{sub par} =2.0024 due to the SO{sup -}{sub 3} centre and the B one with g{sub 1}=2.0005; g{sub 2}=2.0001; g{sub 3}=1.9998 due to mechanical powder reduction (drilling). Owing to heating and simultaneous experiments, a correlation have been established: the 280 deg. C TL peak is associated to the A signal and thus to the SO{sup -}{sub 3} centre and the 360 deg. C TL peak is caused by mechanical treatment corresponding to the B EPR signal.

  2. EPR and TL correlation in some powdered Greek white marbles.

    Science.gov (United States)

    Baïetto, V; Villeneuve, G; Guibert, P; Schvoerer, M

    2000-02-01

    Thermoluminescence of white powdered marble samples, chosen to display different EPR spectra, were studied. Two peaks at 280 degrees C and 360 degrees C can be observed among the TL glow curves while the EPR spectra exhibit two signals: the A signal with g perpendicular = 2.0038 and g parallel = 2.0024 due to the SO3- centre and the B one with g1 = 2.0005; g2 = 2.0001; g3 = 1.9998 due to mechanical powder reduction (drilling). Owing to heating and simultaneous experiments, a correlation have been established: the 280 degrees C TL peak is associated to the A signal and thus to the SO3- centre and the 360 degrees C TL peak is caused by mechanical treatment corresponding to the B EPR signal.

  3. Stability of detecting system using NaI(Tl)

    International Nuclear Information System (INIS)

    Zhuo Yunshang; Lei Zhangyun; Zen Yu; Gong Hua

    1996-01-01

    A detecting system using NaI(Tl) is widely used in research and industry of nuclear science and other fields. For providing the high accuracy and working well under inclement environment, the stability of detecting system using NaI(Tl) is very important. The variation of environment temperature, the change of counting rate and long time continuous working of detector will cause un-negligible effect on the measurement. Three approaches were used. They are: 1) temperature control (It makes the effect of the variation of environment temperature on the measurement negligible.); 2) spectrum stabilizing (It adjust the peak position of the spectrum when the counting rate changes.); and 3) auto-checking and adjusting (It adjusts the drift of the NaI(Tl) detecting system when it works continuously)

  4. Telomere Length, Proviral Load and Neurologic Impairment in HTLV-1 and HTLV-2-Infected Subjects

    Directory of Open Access Journals (Sweden)

    Benjamin Usadi

    2016-08-01

    Full Text Available Short or damaged telomeres have been implicated in degenerative conditions. We hypothesized that analysis of telomere length (TL in human T-cell lymphotropic virus (HTLV infection and HTLV-associated neuropathy might provide clues to the etiology of HTLV-associated disease and viral dynamics. A subset of 45 human T-cell lymphotropic virus type 1 (HTLV-1, 45 human T-cell lymphotropic virus type 2 (HTLV-2, and 45 seronegative subjects was selected from the larger HTLV Outcomes Study (HOST cohort, matched on age, sex and race/ethnicity. Telomere-to-single-copy gene (T/S ratio (a measure of TL and HTLV-1 and HTLV-2 proviral loads were measured in peripheral blood mononuclear cells (PBMCs using quantitative PCR (qPCR. Vibration sensation measured by tuning fork during neurologic examinations performed as part of the HOST study allowed for an assessment of peripheral neuropathy. TL was compared between groups using t-tests, linear and logistic regression. Mean T/S ratio was 1.02 ± 0.16 in HTLV-1, 1.03 ± 0.17 in HTLV-2 and 0.99 ± 0.18 in HTLV seronegative subjects (p = 0.322. TL was not associated with HTLV-1 or -2 proviral load. Shorter TL was significantly associated with impaired vibration sense in the HTLV-2 positive group only. Overall, we found no evidence that telomere length was affected by chronic HTLV-1 and HTLV-2 infection. That TL was only associated with peripheral neuropathy in the HTLV-2-positive group is intriguing, but should be interpreted cautiously. Studies with larger sample size and telomere length measurement in lymphocyte subsets may clarify the relationship between TL and HTLV-infection.

  5. Standardization of 201Tl and 55Fe radionuclides in a 4 (PC)-NaI(Tl) coincidence system

    International Nuclear Information System (INIS)

    Pires, Carlos Augusto

    2008-01-01

    In the present work the procedure for the standardization of radionuclides using the 4π(PC)-NaI(Tl) coincidence system was developed. The radionuclides selected were 201 Tl, used in nuclear medicine, and 55 Fe primary standard source, used for x-ray spectrometers calibration. The 4π(PC)-NaI(Tl) is composed of a 4 proportional counter operated at 0.1MPa coupled to two NaI(Tl) crystals. The 201 Tl decays by electron capture process followed by a prompt gamma-ray. The disintegration rate was determined by extrapolation technique using two methods: electronic discrimination and external absorbers. The radioactive sources were prepared in a 20 μg cm -2 thick Collodion film. The conventional electronic system was used. The observed events were registered by the TAC method. The 55 Fe decays by electron capture process to the ground state of 55 Mn, emitting x rays with around 6 keV. The standardization was obtained by the tracing method. This technique was applied using two radionuclides, which decay by electron capture process followed by a prompt gamma-ray, namely 51 Cr and 54 Mn, as tracers. Measurements with 1 and 2 aluminum foils, each 150 g cm-2 thick were carried out. The activity was obtained by extrapolation for zero thickness Al foil. The uncertainties were treated by means of matrix covariance methodology and takes into account all correlations involved. (author)

  6. Expanding the Teaching Commons: Making the Case for a New Perspective on SoTL

    Directory of Open Access Journals (Sweden)

    Kim A. Case, PhD

    2013-08-01

    Full Text Available As a reflection on O’Meara, Terosky, and Neumann’s (2011 work on scholarship of teaching and learning (SoTL faculty development, this essay describes the benefits of SoTL to individual faculty and university goals. In support and expansion of arguments advanced by O’Meara et al., this work calls for the use of SoTL faculty development to promote the shared teaching commons, active recruitment of new SoTL scholars, institutionalization of SoTL values, and integration of SoTL initiatives in both teaching centers and research-focused development offices.

  7. Intrarenal blood flow distribution in dog kidney determined by /sup 99m/Tc microaggregates and 201Tl

    International Nuclear Information System (INIS)

    Abildgaard, U.; Amtorp, O.; Gyring, J.; Daugaard, G.; Larsen, B.

    1988-01-01

    Intrarenal distribution of blood flow was assessed with radioactive albumin microaggregates (MA) in three cortical zones of the dog kidney. The experimentally obtained zonal fractions of total renal blood flow were compared with predicted zonal blood flow fractions obtained in a mathematical model. The maximal degree of skimming that could possibly occur in a single experiment was estimated. The analysis showed that local blood flow in the inner cortical zone was maximally underestimated by 17% because of skimming of MA, and in the outer cortical zone the blood flow was maximally overestimated by 13% with the method of radioactive MA uptake. Renal uptake of 201 Tl was measured simultaneously in exactly the same locations. Paired measurements of intrarenal blood flow distribution by MA and Tl uptake methodologies showed that local blood flow assessed with MA in the inner cortical zone was significantly lower than that obtained with 201 Tl and that a higher blood flow rate was obtained in the outer cortical zone with MA compared with 201 Tl. This disparity could be accounted for by the effect of skimming of MA as predicted by the model

  8. Critical Care Admissions following Total Laryngectomy: Is It Time to Change Our Practice?

    Science.gov (United States)

    Walijee, Hussein; Morgan, Alexandria; Gibson, Bethan; Berry, Sandeep; Jaffery, Ali

    2016-01-01

    Critical Care Unit (CCU) beds are a limited resource and in increasing demand. Studies have shown that complex head and neck patients can be safely managed on a ward setting given the appropriate staffing and support. This retrospective case series aims to quantify the CCU care received by patients following total laryngectomy (TL) at a District General Hospital (DGH) and compare patient outcomes in an attempt to inform current practice. Data relating to TL were collected over a 5-year period from 1st January 2010 to 31st December 2015. A total of 22 patients were included. All patients were admitted to CCU postoperatively for an average length of stay of 25.5 hours. 95% of these patients were admitted to CCU for the purpose of close monitoring only, not requiring any active treatment prior to discharge to the ward. 73% of total complications were encountered after the first 24 hours postoperatively at which point patients had been stepped down to ward care. Avoiding the use of CCU beds and instead providing the appropriate level of care on the ward would result in a potential cost saving of approximately £8,000 with no influence on patient morbidity and mortality.

  9. The model of recombination process in TlBr

    International Nuclear Information System (INIS)

    Grigorjeva, L.; Millers, D.

    2002-01-01

    The time-resolved luminescence was used as a tool in the study of recombination process in several undoped TlBr crystals. The spectra and decay kinetics observed under electron beam excitation were investigated. Observation of several luminescence bands with different decay rates shows that more than one recombination center is involved and the recombination process is quite complicated. The band at ∼2.5 eV is dominant under 10 ns excitation pulse (electron beam or nitrogen laser pulses). The results of short-lived absorption and luminescence are used for analysis of possible mechanisms of recombination processes in TlBr

  10. Portable in situ NaI(Tl) γ spectroscopy system

    International Nuclear Information System (INIS)

    Wang Bairong; Dong Binjiang; Zeng Liping; Shen Tingyun

    2000-01-01

    The author describes a portable in situ NaI(Tl) γ spectroscopy system, which consists of a NaI (Tl) scintillation detector, an integrative spectroscopy card, a notebook computer and spectroscopy software. The spectrometer addresses applications in environmental or nuclear accident in situ γ spectroscopy measurements, and gives valid quantitative results of radionuclide concentrations per unit volume (Bq/kg) or unit area (Bq/cm 2 ) in the soil and absorbed dose rate in air at 1 m above ground (Gy/h)

  11. Coronary spasm: 201Tl scintiscanning following pharmacological provocation

    International Nuclear Information System (INIS)

    Montz, R.; Mathey, D.; Bleifeld, W.; Hamburg Univ.

    1981-01-01

    According to the authors' experience so far, 201 Tl myocardial scintiscanning is a sufficiently sensitive non-invasive method for detection of coronary vasospasm provoked by ergotamine administration. Mild incomplete and asymptotic forms of coronary vasospasm were detected by scintiscanning. Indications for myocardial scintiscanning of ergotamine-provoked vasospasm are: Cases of angina pectoris at rest in which electrocardiograms during spasm are not available; elleviated symptoms after nitroglycerine administration; exercise electrocardiograms without any sign of ischaemia; negative results of exercise 201 Tl myocardial scintiscanning. (orig.) [de

  12. Thermoluminescence (TL) in the identification of irradiated food

    International Nuclear Information System (INIS)

    Luthra, J.M.

    1992-01-01

    Due to progressive expansion of commercial food irradiation in recent years, the interest in detecting whether a food has been irradiated or not is growing fast and research in several methods for identification of various irradiated food stuffs is the order of the day. TL has emerged as one of the most promising tool for distinguishing between irradiated and unirradiated food. Advantages of TL method over other physical methods, its application to various foods, limitation and present state of art are discussed.(author). 9 refs., 3 tabs

  13. Automation of TL brick dating by ADAM-1

    International Nuclear Information System (INIS)

    Cechak, T.; Gerndt, J.; Hirsl, P.; Jirousek, P.; Kubelik, M.; Musilek, L.; Kanaval, J.

    2000-01-01

    Thermoluminescence has become an established dating method for ceramics and more recently for bricks. Based on the experiences of the work carried out since the late 1970's at the Rathgen-Forschungslabor in Berlin on the dating of bricks from historic architecture, and after evaluating all commercially available and some individually built automated and semi-automated TL-readers, a specially adapted machine for the fine grain dating of bricks was constructed in an interdisciplinary research project, undertaken by a team recruited from three faculties of the Czech Technical University in Prague. The result is the automated TL-reader ADAM-1 (Automated Dating Apparatus for Monuments) for the dating of historic architecture. Both the specific adaptation of the technique and the necessary optimal automation have influenced the design of this TL-reader. The principle advantage of brick as opposed to ceramic TL-dating emerges from the possibility of being able to obtain both a large number of samples and an above average quantity of datable material from each sample. This, together with the specific physical and chemical conditions in a brick wall, allowed a rethinking of the traditional error calculation and thus lower error margins as those obtained when dating ceramic shards. The TL-reader must therefore be able to measure and evaluate automatically numerous samples. The annular sample holder of ADAM-1 has 60 sample positions, which allow the irradiation and evaluation of samples taken from two locations. The thirty samples from one sampling point are divided into subgroups, which are processed in various ways. Three samples serve for a rough estimate of the TL sensitivity of the brick material. Nine samples are used for the measurement of 'natural TL' of the material. A further nine samples are used for testing the sensitivity of the material to beta radiation. The last nine samples serve for the testing of the sensitivity to alpha radiation. To determine the

  14. Calculated Absolute Detection Efficiencies of Cylindrical Nal (Tl) Scintillation Crystals for Aqueous Spherical Sources

    Energy Technology Data Exchange (ETDEWEB)

    Strindehag, O; Tollander, B

    1968-08-15

    Calculated values of the absolute total detection efficiencies of cylindrical scintillation crystals viewing spherical sources of various sizes are presented. The calculation is carried out for 2 x 2 inch and 3 x 3 inch Nal(Tl) crystals and for sources which have the radii 1/4, 1/2, 3/4 and 1 times the crystal radius. Source-detector distances of 5-20 cm and gamma energies in the range 0.1 - 5 MeV are considered. The correction factor for absorption in the sample container wall and in the detector housing is derived and calculated for a practical case.

  15. Alpha efficiency under TL and OSL - A subtraction technique using OSL and TL to detect artificial irradiation

    International Nuclear Information System (INIS)

    Zink, A.J.C.; Dabis, S.; Porto, E.; Castaing, J.

    2010-01-01

    With the development of thermoluminescence (TL) and optically stimulated luminescence (OSL) to determine the authenticity of old ceramics, forgers use artificial irradiation by gamma ray to age modern productions. Besides fraudulent action, objects can be exposed to various sources of X-rays (e.g. radiography, security control at airports). For all these reasons, the determination of artificial irradiation is an important topic for dating art objects. The main technique to identify artificial irradiations is the subtraction technique. It is based on the fact that alpha efficiency varies according to the luminescence technique (fine grain, coarse grains, predose, OSL). Having observed a rather significant difference of alpha efficiency for TL and OSL, we propose a new subtraction technique using OSL and TL of fine grains.

  16. Telomere Length and Mortality

    DEFF Research Database (Denmark)

    Kimura, Masayuki; Hjelmborg, Jacob V B; Gardner, Jeffrey P

    2008-01-01

    Leukocyte telomere length, representing the mean length of all telomeres in leukocytes, is ostensibly a bioindicator of human aging. The authors hypothesized that shorter telomeres might forecast imminent mortality in elderly people better than leukocyte telomere length. They performed mortality...

  17. Smoking and perceived stress in relation to short salivary telomere length among caregivers of children with disabilities.

    Science.gov (United States)

    Chen, Xiaoli; Velez, Juan Carlos; Barbosa, Clarita; Pepper, Micah; Andrade, Asterio; Stoner, Lee; De Vivo, Immaculata; Gelaye, Bizu; Williams, Michelle A

    2015-01-01

    Telomere length (TL), the length of repeated DNA sequence that forms protective caps at the end of chromosomes, has emerged as a novel biomarker of cell aging and oxidative stress. There is increasing research exploring the associations of smoking and perceived stress with TL, and the results are inconsistent. This study aimed to examine whether smoking and perceived stress were associated with shortened salivary TL among primary caregivers of children with disabilities. Using a quantitative polymerase chain reaction method, salivary TL was assessed among 89 caregivers aged 19-69 years (87% were women) who took care of disabled children in the Patagonia Region, Chile. Interviewer-administered questionnaires were used to collect information on sociodemographic and lifestyle factors. The 14-item Perceived Stress Scale was used to assess perceived stress. Mean relative TL was 0.92 (standard error = 0.03). Smokers had age-adjusted mean TL that was 0.07 units lower (β = -0.07, standard error = 0.03; p = 0.012) than non-smokers. Smokers were 2.17 times more likely to have shorter TL ( stress. Caregivers with higher perceived stress were 2.13 times more likely to have shorter TL (odds ratio = 3.13; 95% confidence interval = 1.03-9.55) than caregivers with lower perceived stress after adjustment for age and smoking. This study provides the first evidence of strong associations between smoking and perceived stress and shortened salivary TL among caregivers of children with disabilities. Larger studies with detailed information on smoking status are warranted to confirm our findings.

  18. Vortex states of Tl2Ba2CuO6+δ studied via 205Tl NMR at 2 tesla

    International Nuclear Information System (INIS)

    Itoh, Yutaka; Michioka, Chishiro; Yoshimura, Kazuyoshi; Hayashi, Akihiko; Ueda, Yutaka

    2005-01-01

    We report a 205 Tl NMR study of vortex states in an aligned polycrystalline sample of an overdoped high-T c superconductor, Tl 2 Ba 2 CuO 6+δ (Tc - 85 K), at a magnetic field of 2 T along the c axis. We observed an imperfect vortex lattice, so-called Bragg glass, at T=5 K, the coexistence of vortex solid and vortex liquid between 10 and 60 K, and vortex melting between 65 and 85 K. No evidence for local antiferromagnetic ordering at vortex cores was found for our sample. (author)

  19. Performance of novel materials for radiation detection: Tl3AsSe3, TlGaSe2, and Tl4HgI6

    International Nuclear Information System (INIS)

    Kahler, D.; Singh, N.B.; Knuteson, D.J.; Wagner, B.; Berghmans, A.; McLaughlin, S.; King, M.; Schwartz, K.; Suhre, D.; Gotlieb, M.

    2011-01-01

    In this paper we report on the electrical characteristics of three novel ternary compounds, Tl 3 AsSe 3 (TAS), TlGaSe 2 (TGS), and Tl 4 HgI 6 (THI), pertaining to their use as radiation detectors. The details for growth and material characterization are not presented. A semiconductor based gamma ray detector requires a material with high Z, high density, high resistivity, appropriate bandgap (1.5-2 eV), low energy/electron-hole pair, and a high μτ product. CZT is currently the best semiconductor material for room temperature gamma ray spectroscopy; however, it is extremely difficult to produce large volumes of detector grade material, making it expensive and in limited supply. DNDO/DHS began searching for other materials that might perform as well as CZT but be easier to grow and in the end lower the cost. For this purpose, we investigated the above three materials as possible replacements for CZT as gamma ray detectors. The bulk resistivity, I-V curves, X-ray response, and gamma ray response measurements for doped and undoped crystals are presented and discussed. TAS shows good X-ray and gamma ray response, but has poor resistivity, which results in large dark current and poor spectral response. TGS has good resistivity, but shows poor X-ray and gamma ray response. THI has excellent resistivity, shows some X-ray and gamma ray response, and has great potential as a gamma ray detector.

  20. Diurnal and stress-reactive dehydroepiandrosterone levels and telomere length in youth.

    Science.gov (United States)

    Dismukes, Andrew R; Meyer, Vanessa J; Shirtcliff, Elizabeth A; Theall, Katherine P; Esteves, Kyle C; Drury, Stacy S

    2016-05-01

    The current investigation examined the association between the aging-related biomarkers dehydroepiandrosterone (DHEA) and telomere length (TL) in community-recruited African-American youth. The examination of DHEA included stress reactive, basal and diurnal sampling, in order to elucidate the underlying physiological process that may overlap with TL. One hundred and two participants completed the Trier Social Stressor Test for children (TSST-C). TL was obtained from all youth from buccal swabs on the same day as the TSST-C. Saliva samples from 83 participants were obtained over the course of two additional days to measure waking and diurnal levels of DHEA. DHEA diurnal slope was a robust predictor of TL (B=0.516, P<0.05), while other DHEA values were not significantly associated with TL. This study is one of the first studies to examine basal, diurnal and reactivity measurements of DHEA in youth. Furthermore, this is the first study, to our knowledge, to demonstrate a positive association between DHEA, a putative anti-aging hormone, and TL, an indicator of cellular aging. © 2016 The authors.

  1. Diurnal and stress-reactive dehydroepiandrosterone levels and telomere length in youth

    Directory of Open Access Journals (Sweden)

    Andrew R Dismukes

    2016-05-01

    Full Text Available The current investigation examined the association between the aging-related biomarkers dehydroepiandrosterone (DHEA and telomere length (TL in community-recruited African-American youth. The examination of DHEA included stress reactive, basal and diurnal sampling, in order to elucidate the underlying physiological process that may overlap with TL. One hundred and two participants completed the Trier Social Stressor Test for children (TSST-C. TL was obtained from all youth from buccal swabs on the same day as the TSST-C. Saliva samples from 83 participants were obtained over the course of two additional days to measure waking and diurnal levels of DHEA. DHEA diurnal slope was a robust predictor of TL (B=0.516, P<0.05, while other DHEA values were not significantly associated with TL. This study is one of the first studies to examine basal, diurnal and reactivity measurements of DHEA in youth. Furthermore, this is the first study, to our knowledge, to demonstrate a positive association between DHEA, a putative anti-aging hormone, and TL, an indicator of cellular aging.

  2. Development of a TL personal dosimeter identifiable PA exposure, and comparison with commercial TL dosimeters

    International Nuclear Information System (INIS)

    Kwon, J.W.; Kim, H.K.; Lee, J.K.; Kim, J.L.

    2004-01-01

    A single-dosimeter worn on the anterior surface of the body of a worker was found to significantly underestimate the effective dose to the worker when the radiation comes from the back. Several researchers suggested that this sort of underestimation can be corrected to a certain extent by using an extra dosimeter on the back. However, use of multiple dosimeters also has disadvantages such as complication in control or incurrence of extra cost. Instead of the common multi-dosimeter approach, in this study, a single dosimeter introducing asymmetric filters which enabled to identify PA exposure was designed, and its dose evaluation algorithm for AP-PA mixed radiation fields was established. A prototype TL personal dosimeter was designed and constructed. The Monte Carlo simulations were utilized in the design process and verified by experiments. The dosimeter and algorithm were applicable to photon radiation having an effective energy beyond 100 keV in AP-PA mixed radiation fields. A simplified performance test based on ANSI N13.11 showed satisfactory results. Considering that the requirements of the International Electrotechnical Commission (IEC) and the American National Standards Institute (ANSI) with regard to the dosimeter on angular dependency is reinforced, the dosimeter and the dose evaluation algorithm developed in this study provides a useful approach in practical personal dosimetry against inhomogeneous high energy radiation fields. (author)

  3. Giant Rashba spin splitting in Bi2Se3: Tl

    KAUST Repository

    Singh, Nirpendra; Saeed, Yasir; Schwingenschlö gl, Udo

    2014-01-01

    First-principles calculations are employed to demonstrate a giant Rashba spin splitting in Bi2Se3:Tl. Biaxial tensile and compressive strain is used to tune the splitting by modifying the potential gradient. The band gap is found to increase under

  4. Preparation of biaxially oriented TlCu-1234 thin films

    CERN Document Server

    Khan, N A; Tateai, F; Kojima, T; Ishida, K; Terada, N; Ihara, H

    1999-01-01

    The single phase of TlCu-1234 superconductor thin films is prepared for the first time by the amorphous phase epitaxy (APE) method, which is thallium treatment of sputtered amorphous phase at 900 degrees C for 1 h. The amorphous $9 phase is prepared by sputtering from the stoichiometric target composition CuBa/sub 2/Ca/sub 3/Cu/sub 4/O/sub 12-y/. The films on the SrTiO/sub 3/ substrate are aligned biaxially after the thallium treatment. Highly reproducible $9 TlCu-1234 films are prepared by this method. The XRD reflected a predominant single phase with the c-axis lattice constant of 18.74 AA. This lattice constant value is in between that of Cu-1234 (17.99 AA) and Tl-1234 (19.11 AA) . The $9 pole figure measurements of (103) reflection of the films showed a-axis-oriented crystals with Delta phi =0.8 degrees . The composition of the films after energy dispersive X-ray (EDX) measurements is Tl/sub 0.8/Cu/sub 0.2/Ba/sub $9 2/Ca/sub 3/Cu/sub 4/O /sub 12-y/. From the resistivity measurements, the T/sub c/ is 113 K...

  5. Reader's Response: What Is a SoTL?

    Science.gov (United States)

    Griebenow, Kai

    2010-01-01

    In this response to, "SoTL Commons Conference: A Spirit of Inquiry" (Margaret Davis, Kera Watkins, and Deborah Allen, "International Journal for the Scholarship of Teaching and Learning,"v3 n2 Jul 2009), Griebenow adds his personal impressions as an "SOTL newbie." He states that many scientists have an idea of…

  6. TL, EPR and optical absorption in natural grossular crystal

    Energy Technology Data Exchange (ETDEWEB)

    Yauri, J.M. [Institute of Physics, University of Sao Paulo, Rua do Matao, Travessa R, 187, CEP 05508-900, Sao Paulo (Brazil); Department of Physics, University of San Agustin, Av. Independencia S/N, Arequipa (Peru); Cano, N.F. [Institute of Physics, University of Sao Paulo, Rua do Matao, Travessa R, 187, CEP 05508-900, Sao Paulo (Brazil)], E-mail: nilocano@dfn.if.usp.br; Watanabe, S. [Institute of Physics, University of Sao Paulo, Rua do Matao, Travessa R, 187, CEP 05508-900, Sao Paulo (Brazil)

    2008-10-15

    Grossular is one of six members of silicate Garnet group. Two samples GI and GII have been investigated concerning their luminescence thermally stimulated (TL). EPR and optical absorption and the measurements were carried out to find out whether or not same point defects are responsible for all three properties. Although X-rays diffraction analysis has shown that both GI and GII have practically the same crystal structure of a standard grossular crystal, they presented different behavior in many aspects. The TL glow curve shape, TL response to radiation dose, the effect of annealing at high temperatures before irradiation, the dependence of UV bleaching parameters on peak temperature, all of them differ going from GI to GII. The EPR signals around g=2.0 as well as at g=4.3 and 6.0 have much larger intensity in GI than in GII. Very high temperature (>800 deg. C) annealing causes large increase in the bulk background absorption in GI, however, only very little in GII. In the cases of EPR and optical absorption, the difference in their behavior can be attributed to Fe{sup 3+} ions; however, in the TL case one cannot and the cause was not found as yet.

  7. Neutron Scattering from fcc Pr and Pr3Tl

    DEFF Research Database (Denmark)

    Birgeneau, R. J.; Als-Nielsen, Jens Aage; Bucher, E.

    1972-01-01

    Elastic-neutron-scattering measurements on the singlet-ground-state ferromagnets fcc Pr and Pr3 Tl are reported. Both exhibit magnetic phase transitions, possibly to a simple ferromagnetic state at 20 and 11.6 °K, respectively. The transitions appear to be of second order although that in fcc Pr...

  8. TL, EPR and optical absorption in natural grossular crystal

    International Nuclear Information System (INIS)

    Yauri, J.M.; Cano, N.F.; Watanabe, S.

    2008-01-01

    Grossular is one of six members of silicate Garnet group. Two samples GI and GII have been investigated concerning their luminescence thermally stimulated (TL). EPR and optical absorption and the measurements were carried out to find out whether or not same point defects are responsible for all three properties. Although X-rays diffraction analysis has shown that both GI and GII have practically the same crystal structure of a standard grossular crystal, they presented different behavior in many aspects. The TL glow curve shape, TL response to radiation dose, the effect of annealing at high temperatures before irradiation, the dependence of UV bleaching parameters on peak temperature, all of them differ going from GI to GII. The EPR signals around g=2.0 as well as at g=4.3 and 6.0 have much larger intensity in GI than in GII. Very high temperature (>800 deg. C) annealing causes large increase in the bulk background absorption in GI, however, only very little in GII. In the cases of EPR and optical absorption, the difference in their behavior can be attributed to Fe 3+ ions; however, in the TL case one cannot and the cause was not found as yet

  9. Thermal and x-ray studies on Tl2U(MoO4)3 and Tl4U(MoO4)4

    International Nuclear Information System (INIS)

    Dahale, N.D.; Keskar, Meera; Kulkarni, N.K.; Singh Mudher, K.D.

    2006-01-01

    In the quaternary Tl-U(IV)-Mo-O system, two new compounds namely Tl 2 U(MoO 4 ) 3 and Tl 4 U(MoO 4 ) 4 were prepared and characterized by powder X-ray diffraction and thermal methods. These compounds were prepared by solid state reactions of Tl 2 MoO 4 , UMoO 5 and MoO 3 in the required stoichiometric ratio at 500 deg C in evacuated sealed quartz ampoule. The XRD data of Tl 2 U(MoO 4 ) 3 and Tl 4 U(MoO 4 ) 4 were indexed on orthorhombic cell. TG curves of Tl 2 U(MoO 4 ) 3 and Tl 4 U(MoO 4 ) 4 did not show any weight change up to 700 deg C in an inert atmosphere. During heating in an inert atmosphere, Tl 2 U(MoO 4 ) 3 and Tl 4 U(MoO 4 ) 4 showed endothermic Dta peaks due to melting of the compounds at 519 and 565 deg C, respectively. (author)

  10. Quality control of the solution sup(201)TlCl obtained at IPEN-CNEN/SP by sup(201)Tl direct preparation

    International Nuclear Information System (INIS)

    Fernandes, L.; Silva, C.P.G. da

    1991-01-01

    The radiopharmaceutical sup(201) TlCl is used in Nuclear Medicine for myocardial visualization. The solution of sup(201)TlCl was prepared using sup(201)Tl obtained by irradiating a natural mercury target with protons. This radionuclide was subjected to different quality control processes to verify the purity required for its use in Medicine. Some of these controls concerned the determination of sup(200)Tl, sup(201)Tl and sup(202)Tl; the chemical identification of sup(201)Tl sup(+1); the hydrazine concentration, mercury contamination and the presence of phosphate. Furthermore, the biologic distribution in Wistar rats and tests for sterility pyrogens and for toxicity were carried out. It was verified that the solution obtained was in the form of tallous chloride. This radiopharmaceutical can give a good heart image in animals but due to the contamination of sup(201)Tl with sup(200)Tl and sup(202)Tl its use in human beings is not possible unless enriched sup(202)Hg is used as target of irradiation. (author)

  11. Investigating the origins of double photopeaks in CsI:Tl samples through activator mapping

    Science.gov (United States)

    Onken, Drew R.; Gridin, Sergii; Williams, Richard T.; Williams, Charles B.; Donati, George L.; Gayshan, Vadim; Vasyukov, Sergey; Gektin, Alex

    2018-06-01

    Careful examination of the origins of double photopeaks in CsI:Tl provides a foundation for exploring the relationship between activator homogeneity and photopeak resolution in scintillators. In rare cases, certain CsI:Tl crystals exhibit a second photopeak in the pulse-height spectrum. A combination of optical mapping and ICP-MS measurements reveals the presence of two distinct regions with differing Tl concentrations in these crystals. The oscillator strength of the 299 nm absorption A-band of Tl in CsI was measured to be 0.0526 ± 0.0008; this parameter can be used to quantify activator concentration from the optical absorption. Using published measurements of luminescence intensity versus Tl concentration, the distributions of Tl measured from optical absorption maps of the samples were reconstructed into photopeaks in good agreement with experiment. The distribution of Tl concentrations in these particular crystals allowed examining luminescence pulse shape as a function of Tl concentration.

  12. Study of combinations of TL/OSL single dosimeters for mixed high/low ionization density radiation fields

    International Nuclear Information System (INIS)

    Oster, L.; Druzhyna, S.; Orion, I.; Horowitz, Y.S.

    2013-01-01

    In this paper we discuss and compare the potential application of combined OSL/TL measurements using 6 LiF:Mg,Ti (TLD-600 is enriched of isotope 6 Li which has a high cross-section for the reaction with slow neutrons) or 7 LiF:Mg,Ti ( TLD-700 is enriched of 7 Li isotope) and TLD-100 (natural isotopic composition) detectors. The OSL/TL duel readout of LiF:Mg,Ti as an ionization density discriminator avoids some of the difficulties inherent to the various types of discrimination mixed-field passive dosimeters, and in addition has several advantages. The preferential excitation of OSL compared to TL following high ionization density (HID) alpha irradiation, naturally explained via the identification of OSL with the “two-hit” F 2 or F 3 center, whereas the major component of composite TL glow peak 5 is believed to arise from a ''one-hit'' complex defect. This evidence allows near-total discrimination between HID radiation and low-ionization density (LID) radiation. Beta and alpha particle irradiations were carried out with 90 Sr/ 90 Y (∼500 keV average energy) and 241 Am sources (4.7 MeV) respectively and neutron irradiations were carried out at the PTB (Germany) (E n = 5 MeV) and RARAF (Columbia University, USA) (E n = 6 MeV) accelerator facilities. The highest values of the FOM obtained was ∼30 for neutron/gamma discrimination and ∼110 for alpha/gamma discrimination using OSL/TL – peak 5 measurements in TLD-700. -- Highlights: ► The increased response of OSL compared to TL following HID irradiation is observed. ► This evidence is explained via the identification of OSL with the ''two-hit'' F2 centers. ► The potential application of combined OSL/TL in discrimination dosimetry is discussed. ► The values of FOM were 110 for alpha/gamma and 30 for neutron/gamma discrimination

  13. First direct observation of bound-state beta-decay: Measurements of branching and lifetime of 207Tl81+ fragments

    International Nuclear Information System (INIS)

    Boutin, D.

    2005-08-01

    The first experimental observation of bound-state beta-decay showed, that due solely to the electron stripping, a stable nuclide, e.g. 163 Dy, became unstable. Also a drastic modification of the half-life of bare 187 Re, from 4.12(2) x 10 10 years down to 32.9(20) years, could be observed. It was mainly due to the possibility for the mother nuclide to decay into a previously inaccessible nuclear level of the daughter nuclide. It was proposed to study a nuclide where this decay mode was competing with continuum-state beta-decay, in order to measure their respective branchings. The ratio β b /β c could also be evaluated for the first time. 207 Tl was chosen due to its high atomic number, and Q-value of about 1.4 MeV, small enough to enhance the β b probability and large enough to allow the use of time-resolved Schottky Mass Spectrometry (SMS) to study the evolution of mother and bound-state beta-decay daughter ions. The decay properties of the ground state and isomeric state of 207 Tl 81+ have been investigated at the GSI accelerator facility in two separate experiments. For the first time β-decay where the electron could go either to a bound state (atomic orbitals) and lead to 207 Pb 81+ as a daughter nuclide, or to a continuum state and lead to 207 Pb 82+ , has been observed. The respective branchings of these two processes could be measured as well. The deduced total nuclear half-life of 255(17) s for 207 Tl 81+ , was slightly modified with respect to the half-life of the neutral atom of 286(2) s. It was nevertheless in very good agreement with calculations based on the assumption that the beta-decay was following an allowed type of transition. The branching β b /β c =0.192(20), was also in very good agreement with the same calculations. The application of stochastic precooling allowed to observe in addition the 1348 keV short-lived isomeric state of 207 Tl. The half-life of this isomeric state was measured as 1.47(32) s, which shows a small deviation

  14. Telomere length is associated with oppositional defiant behavior and maternal clinical depression in Latino preschool children.

    Science.gov (United States)

    Wojcicki, J M; Heyman, M B; Elwan, D; Shiboski, S; Lin, J; Blackburn, E; Epel, E

    2015-06-16

    Exposure to psychological stress and depression are associated with shorter white blood cell telomere length (TL) in adults, possibly via associated lifelong oxidative stressors. Exposure to maternal depression increases risk for future depression and behavior problems in children, and Latino youth are at high risk. Few studies have evaluated the role of exposure to maternal depression or child behavior in relation to TL in children. We assessed early-childhood exposures to maternal depression from birth to the age of 5 years and child behavior from ages 3-5 years in a cohort of Latino children in relation to child leukocyte TL at ages 4 and 5 years. Children who had oppositional defiant behavior at 3, 4 or 5 years had shorter TL than those without by ~450 base pairs (P maternal clinical depression at 3 years of age (β = -363.99, 95% CI -651.24 to 764.74; P = 0.01), shorter maternal TL (β = 502.92, 95% CI 189.21-816.63) and younger paternal age at the child's birth (β = 24.63, 95% CI 1.14-48.12). Thus, exposure to maternal clinical depression (versus depressive symptoms) in early childhood was associated with deleterious consequences on child cellular health as indicated by shorter TL at 4 and 5 years of age. Similarly, children with oppositional defiant behavior also had shorter TL, possibly related to early exposures to maternal clinical depression. Our study is the first to link maternal clinical depression and oppositional defiant behavior with shorter TL in the preschool years in a relatively homogenous population of low-income Latino children.

  15. Experimental studies on radiation damages of CsI(Tl) crystals

    International Nuclear Information System (INIS)

    He Jingtang; Mao Yufang; Dong Xiaoli; Chen Duanbao; Li Zuhao

    1997-01-01

    The results of experimental studies on radiation damage of CsI(Tl) crystal were reported. There are radiation damage effects on CsI(Tl) crystal. Experimental studies on recovery of damaged CsI(Tl) crystals were made. It seems that after heating at 200 degree C for 4 hours, the damaged crystals could be recovered completely

  16. Left ventricular ejection fraction determined by gated Tl-201 perfusion SPECT and quantitative software

    International Nuclear Information System (INIS)

    Hyun, In Young; Kim, Sung Eun; Seo, Jeong Kee; Hong, Eui Soo; Kwan, Jun; Park, Keum Soo; Lee, Woo Hyung

    2000-01-01

    We compared estimates of ejection fraction (EF) determined by gated Tl-201 perfusion SPECT (g-Tl-SPECT) with those by gated blood pool (GBP) scan. Eighteen subjects underwent g-Tl-SPECT and GBP scan. After reconstruction of g-Tl-SPECT, we measured EF with Cedars software. The comparison of the EF with g-Tl-SPECT and GBP scan was assessed by correlation analysis and Bland Altman plot. The estimates of EF were significantly different (p<0.05) with g-Tl-SPECT (40%±14%) and GBP scan (43%±14%). There was an excellent correlation of EF between g-Tl-SPECT and GBP scan (r=3D0.94, p<0.001). The mean difference of EF between GBP scan and g-Tl-SPECT was +3.2%. Ninety-five percent limits of agreement were ±9.8%. EF between g-Tl-SPECT and GBP scan were in poor agreement. The estimates of EF by g-Tl-SPECT was well correlated with those by GBP scan. However, EF of g-Tl-SPECT doesn't agree with EF of GBP scan. EF of g-Tl-SPECT can't be used interchangeably with EF of GBP scan.=20

  17. Challenges to Disciplinary Knowing and Identity: Experiences of Scholars in a SoTL Development Program

    Science.gov (United States)

    Miller-Young, Janice E.; Yeo, Michelle; Manarin, Karen

    2018-01-01

    Faculty members from five years of an annual Scholarship of Teaching and Learning (SoTL) development program were invited to participate in a study about the impact of SoTL on their teaching, scholarship, and career trajectory. During semi-structured interviews, many expressed feeling discomfort during their journey into SoTL. A qualitative…

  18. High current Tl-203, Rh-103 targets preparation for cyclotron production of Tl-201 and Pd-103 radionuclides

    International Nuclear Information System (INIS)

    Arzumanov, A.; Berger, V.; Borissenko, A.; Gorodisskaya, N.; Ilmatov, I.; Knyazev, A.; Koptev, V.; Lyssukhin, S.; Platov, A.; Sychikov, G.; Zheltov, D.

    2004-01-01

    The objectives of the present work are to increase thermal stability of cyclotron targets for production of Tl-201 isotope, increase Tl-203 regeneration rate at radiochemical reprocessing of the targets and develop production technology for radiochemical sources based on Rd-103 isotope. Electrochemical coating of copper substrate with Tl increased the beam current at target irradiation from 100 μA to 125 μA. Further increase of the beam current results in sharp decrease of target stability time at irradiation to 15 min at beam current 150 μA. Thermal calculations and tests at the electron-beam stand predict satisfactory stability at such currents. The discrepancy with the irradiation results has not been explained. More accurate specification of regimes for Tl-203 electrochemical recovery from irradiated targets and better matching of the electrolyte composition made it possible to increase the recovery rate up to 99.5%. Before the present Project, the INP had no experience in production of radioactive sources based on Pd-103. Thermo-diffusion extraction of Pd-103 from irradiated rhodium foil has been chosen as a technology-defining method. The process assures good extraction rate and high purity of extracted isotope. Production of Pd-103 sources based on this technology is much simpler compared to the same based on electrochemical processes. (author)

  19. Systematic and Cell Type-Specific Telomere Length Changes in Subsets of Lymphocytes

    Directory of Open Access Journals (Sweden)

    Jue Lin

    2016-01-01

    Full Text Available Telomeres, the protective DNA-protein complexes at the ends of linear chromosomes, are important for genome stability. Leukocyte or peripheral blood mononuclear cell (PBMC telomere length is a potential biomarker for human aging that integrates genetic, environmental, and lifestyle factors and is associated with mortality and risks for major diseases. However, only a limited number of studies have examined longitudinal changes of telomere length and few have reported data on sorted circulating immune cells. We examined the average telomere length (TL in CD4+, CD8+CD28+, and CD8+CD28− T cells, B cells, and PBMCs, cross-sectionally and longitudinally, in a cohort of premenopausal women. We report that TL changes over 18 months were correlated among these three T cell types within the same participant. Additionally, PBMC TL change was also correlated with those of all three T cell types, and B cells. The rate of shortening for B cells was significantly greater than for the three T cell types. CD8+CD28− cells, despite having the shortest TL, showed significantly more rapid attrition when compared to CD8+CD28+ T cells. These results suggest systematically coordinated, yet cell type-specific responses to factors and pathways contribute to telomere length regulation.

  20. Dual parameter analysis of CsI:Tl/PMT with a digital oscilloscope

    CERN Document Server

    Devol, T A; Fjeld, R A

    1999-01-01

    Scintillation pulses from alpha-particle and gamma-ray excited CsI:Tl were recorded with a photomultiplier tube and digital oscilloscope card in single parameter (pulse shape or pulse height) and dual parameter (simultaneous pulse shape and pulse height) modes. A 2.8x1.3x1.3 cm sup 3 CsI:Tl crystal was coupled to a Burle 8850 photomultiplier tube (PMT) and excited with sup 1 sup 4 sup 8 Gd (E subalpha=3.18 MeV) and sup 1 sup 3 sup 7 Cs (E subgamma=0.662 MeV). The timing pulses (50 OMEGA terminated dynode signal) from the PMT base were directly input to a GaGe CompuScope 8012A/PCI sup T sup M (12-bit, 50 MHz dual channel digital oscilloscope card) that resided in a P6-300 MHz personal computer. Individual digitized pulses were processed via a LabVIEW sup T sup M V 4.1 interface to the oscilloscope. The ratio of the charge collected over a short time interval to the total charge collected was used for the single parameter pulse shape spectrum while the total charge collected was used for the single parameter pu...

  1. Importance of controlling the Tl-oxide partial pressure throughout the processing of TlBa2CaCu2O7 thin films

    International Nuclear Information System (INIS)

    Siegal, M.P.; Venturini, E.L.; Newcomer, P.P.; Overmyer, D.L.; Dominguez, F.; Dunn, R.

    1995-01-01

    TlBa 2 CaCu 2 O 7 (Tl-1212) superconducting films 5000--6000 A thick have been grown on LaAlO 3 (100) substrates using oxide precursors in a closed two-zone thallination furnace. Tl-1212 films can be grown with transition temperatures ∼100 K, and critical current densities measured by magnetization of J cm (5 K)>10 7 A/cm 2 and J cm (77 K)>10 5 A/cm 2 . Processing conditions, substrate temperatures and Tl-oxide source temperatures are found which result in smooth, nearly phase-pure Tl-1212 films. Variations in the respective temperature ramps of the Tl-oxide zone and the substrate zone can greatly influence resulting film properties such as microstructure, morphology, superconducting transition temperature, and critical current density. copyright 1995 American Institute of Physics

  2. Tl myocardial SPECT demonstrates importance of collateral circulation in patients with myocardial infarction

    International Nuclear Information System (INIS)

    Hattori, Fukunori

    1997-01-01

    The influence of collateral circulation on the preservation of myocardial viability and the efficacy of drug therapy and PTCA were evaluated by exercise 201 Tl myocardial SPECT before and after treatment. Thirty-five patients with a history of myocardial infarction resulting from total or subtotal obstruction of the responsible coronary artery were divided into four groups, according to the method of the treatment and the degree of collateral blood flow. Patients in groups A and B received drug therapy and displayed developed and undeveloped collateral circulation, respectively. Groups C and D received PTCA and displayed developed and undeveloped collateral circulation, respectively. Tl myocardial SPECT was performed before treatment to record the extent of redistribution to the occluded region, the degree of myocardial viability and the nature and extent of the ischemic lesion. In group A, myocardial perfusion improved, although redistribution remained in all cases, while in group B, 4 of 7 cases improved after drug therapy. In group C, myocardial perfusion improved in all cases, and redistribution disappeared in 7 of 12 cases. 5 of 6 cases improved in group D after PTCA. After drug therapy, the %Tl uptake in the infarcted region improved significantly in initial and delayed images of patients in group A. The differences in initial and delayed images in group B before and after drug therapy were not significant. In contrast, groups C and D both registered significant improvement in initial and delayed images after PTCA. The washout rate improved significantly in groups A, C and D after their respective treatments. These results suggest that developed collateral circulation helps to preserve myocardial viability in cases of myocardial infarction. Myocardial perfusion improved after drug therapy in cases with developed collateral circulation, and in patients with developed and undeveloped collateral circulation receiving PTCA. (K.H.)

  3. Analysis of glow curves of TL readouts of CaSO4:Dy teflon based TLD badge in semiautomatic TLD badge reader

    International Nuclear Information System (INIS)

    Pradhan, S.M.; Sneha, C.; Adtani, M.M.

    2010-01-01

    The facility of glow curve storage and recall provided in the reader software is helpful for manual screening of the glow curves; however no further analysis is possible due to absence of numerical TL data at the sampling intervals. In the present study glow curves are digitized by modifying the reader software and then normalized to make them independent of the dose. The normalized glow curves are then analyzed by dividing them into five equal parts on time scale. This method of analysis is used to correlate the variation of total TL counts of the three discs with time elapsed post irradiation

  4. Mechanisms of TL for production of the 230 {sup o}C peak in natural sodalite

    Energy Technology Data Exchange (ETDEWEB)

    Cano, Nilo F., E-mail: nilocano@dfn.if.usp.b [Institute of Physics, University of Sao Paulo, Rua do Matao, Travessa R, 187, CEP 05508-090, Sao Paulo (Brazil); Professional School of Physics, University of San Agustin of Arequipa, Av. Independencia S/N, Arequipa (Peru); Blak, Ana R. [Institute of Physics, University of Sao Paulo, Rua do Matao, Travessa R, 187, CEP 05508-090, Sao Paulo (Brazil); Ayala-Arenas, Jorge S. [Professional School of Physics, University of San Agustin of Arequipa, Av. Independencia S/N, Arequipa (Peru); Watanabe, Shigueo [Institute of Physics, University of Sao Paulo, Rua do Matao, Travessa R, 187, CEP 05508-090, Sao Paulo (Brazil)

    2011-02-15

    The thermoluminescence (TL) peak in natural sodalite near 230 {sup o}C, which appears only after submitted to thermal treatments and to gamma irradiation, has been studied in parallel with electron paramagnetic resonance (EPR) spectrum appearing under the same procedure. This study revealed a full correlation between the 230 {sup o}C TL peak and the eleven hyperfine lines from EPR spectrum. In both case, the centers disappear at the same temperature and are restored after gamma irradiation. A complete model for the 230 {sup o}C TL peak is presented and discussed. In addition to the correlation and TL model, specific characteristics of the TL peaks are described.

  5. Electronic band structure study of colossal magnetoresistance in Tl 2Mn 2O 7

    Science.gov (United States)

    Seo, D.-K.; Whangbo, M.-H.; Subramanian, M. A.

    1997-02-01

    The electronic structure of Tl 2Mn 2O 7 was examined by performing tight binding band calculations. The overlap between the Mn t 2g- and Tl 6 s-block bands results in a partial filling of the Tl 6 s-block bands. The associated Fermi surface consists of 12 cigar-shape electron pockets with each electron pocket about {1}/{1000} of the first Brillouin zone in size. The Tl 6 s-block bands have orbital contributions from the Mn atoms, and the carrier density is very low. These are important for the occurrence of a colossal magnetoresistance in Tl 2Mn 2O 7.

  6. Effects of smoking on myocardial injury in patients with conservatively treated acute myocardial infarction. A study with resting {sup 123}I-15-iodophenyl 3-methyl pentadecanoic acid/{sup 201}Tl myocardial single photon emission computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Yamagishi, Hiroyuki; Akioka, Kaname; Shirai, Naoya; Yoshiyama, Minoru; Teragaki, Masakazu; Takeuchi, Kazuhide; Yoshikawa, Junichi; Ochi, Hironobu [Osaka City Univ. (Japan). Graduate School of Medicine

    2001-09-01

    Many reports have demonstrated that smokers who have suffered an acute myocardial infarction (AMI) have a better prognosis than nonsmokers. The present study investigated the effects of current smoking on myocardial injury with resting {sup 123}I-15-iodophenyl 3-methyl pentadecanoic acid (BMIPP)/{sup 201}Tl myocardial single photon emission computed tomography in 103 patients with conservatively treated AMI. The left ventricular myocardium was divided into 9 segments and BMIPP and {sup 201}Tl defects were scored using a 5-point grading system (0=normal and 4=no uptake). The sum of the defect scores was defined as the total defect score. There was no significant difference in either the baseline severity of the coronary artery discase or the total defect scores for BMIPP and {sup 201}Tl between the current smoker and nonsmoker groups. The difference between the total defect scores for BMIPP and {sup 201}Tl tended to be larger in the current smoker group than in the nonsmoker group (2.0{+-}1.9 vs 1.3{+-}1.6, p=0.056). Forty-one (53%) of 77 patients in the current smoker group exhibited a BMIPP/{sup 201}Tl mismatch, whereas only 8 (31%) of 26 patients in the nonsmoker group did (p=0.047). In conclusion, current smokers had more likelihood of salvageable myocardium in areas at risk, as demonstrated by BMIPP/{sup 201}Tl mismatch, in AMI than nonsmokers. (author)

  7. Effects of smoking on myocardial injury in patients with conservatively treated acute myocardial infarction. A study with resting 123I-15-iodophenyl 3-methyl pentadecanoic acid/201Tl myocardial single photon emission computed tomography

    International Nuclear Information System (INIS)

    Yamagishi, Hiroyuki; Akioka, Kaname; Shirai, Naoya; Yoshiyama, Minoru; Teragaki, Masakazu; Takeuchi, Kazuhide; Yoshikawa, Junichi; Ochi, Hironobu

    2001-01-01

    Many reports have demonstrated that smokers who have suffered an acute myocardial infarction (AMI) have a better prognosis than nonsmokers. The present study investigated the effects of current smoking on myocardial injury with resting 123 I-15-iodophenyl 3-methyl pentadecanoic acid (BMIPP)/ 201 Tl myocardial single photon emission computed tomography in 103 patients with conservatively treated AMI. The left ventricular myocardium was divided into 9 segments and BMIPP and 201 Tl defects were scored using a 5-point grading system (0=normal and 4=no uptake). The sum of the defect scores was defined as the total defect score. There was no significant difference in either the baseline severity of the coronary artery discase or the total defect scores for BMIPP and 201 Tl between the current smoker and nonsmoker groups. The difference between the total defect scores for BMIPP and 201 Tl tended to be larger in the current smoker group than in the nonsmoker group (2.0±1.9 vs 1.3±1.6, p=0.056). Forty-one (53%) of 77 patients in the current smoker group exhibited a BMIPP/ 201 Tl mismatch, whereas only 8 (31%) of 26 patients in the nonsmoker group did (p=0.047). In conclusion, current smokers had more likelihood of salvageable myocardium in areas at risk, as demonstrated by BMIPP/ 201 Tl mismatch, in AMI than nonsmokers. (author)

  8. Two crystal structures of Ag sup + -and Tl sup + -exchanged zeolite X, Ag sub 2 sub 7 Tl sub 6 sub 5 -X and Ag sub 2 sub 3 Tl sub 6 sub 9 -X

    CERN Document Server

    Kim, S Y; Kim, Y

    2002-01-01

    Two crystal structures of dehydrated Ag sup + -and Tl sup + -exchanged zeolite X (Ag sub 2 sub 7 Tl sub 6 sub 5 -X and Ag sub 2 sub 3 Tl sub 6 sub 9 -X) have been determined by single-crystal X-ray diffraction techniques in the cubic space group Fd3 at 21(1) .deg. C (a = 24.758(4) A, a = 24.947(4) A, respectively). Their structures were refined to the final error indices R sub 1 = 0.055 and wR sub 2 = 0.057 with 375 reflections, and R sub 1 = 0.058 and wR sub 2 = 0.057 with 235 reflections, respectively, for which I> 3 sigma(I). In the structure of Ag sub 2 sub 7 Tl sub 6 sub 5 -X, 27 Ag sup + ions were found at two crystallographic sites: 15 Ag sup + ions at site I at the center of the hexagonal prism and the remaining 12 Ag sup + ions at site II' in the sodalite cavity. Sixty-five Tl sup + ions were located at three crystallographic sites: 20 Tl sup + ions at site II opposite single six-rings in the supercage, 18 Tl sup + ions at site I' in the sodalite cavity opposite the D6Rs, and the remaining 27 Tl sup ...

  9. Characterization of TL dosimeters for determination of the gamma component in a mixed n+γ radiation field

    International Nuclear Information System (INIS)

    Ranogajec-Komor, M.; Miljanic, S.; Ferek, S.; Dvornik, I.; Osvay, M.

    1996-01-01

    In the International Intercomparison of the Criticality Accident Dosimetry Systems organized by the Commission of European Communities at SILENE Reactor in Valduc, France, 1993, the Ruder Boskovic Institute (RBI) measured the total neutron and gamma tissue absorbed dose (D n+γ ) at the body surface irrespective of neutron and gamma energy spectra variations using the chemical dosimeters DL-M4. For deriving the neutron dose i.e recoil dose, D n , from the differences D n = D n+γ - D t , the total gamma dose (D tγ ) has to be measured with highest accuracy. The determination of the gamma dose in a mixed field is complicated because TL dosimeters are sensitive both to neutrons and gammas. Besides, the radiation doses and energy spectra vary because of scattering and absorption in the body or phantom. Therefore dosimeters with different sensitivities, energy dependences and encapsulations have to be used. In this paper only the study of some characteristics of various TL detectors, such as sensitivity, linearity, supralinearity and fading, for measurement of the gamma component are described. These investigations were carried out in RBI before and after the Valduc intercomparison experiments. The encapsulations, TL response corrections for thermal and fast neutron effects as well as the discussion of Valduc results will be published later

  10. Genome-wide association study of telomere length among South Asians identifies a second RTEL1 association signal.

    Science.gov (United States)

    Delgado, Dayana A; Zhang, Chenan; Chen, Lin S; Gao, Jianjun; Roy, Shantanu; Shinkle, Justin; Sabarinathan, Mekala; Argos, Maria; Tong, Lin; Ahmed, Alauddin; Islam, Tariqul; Rakibuz-Zaman, Muhammad; Sarwar, Golam; Shahriar, Hasan; Rahman, Mahfuzar; Yunus, Mohammad; Jasmine, Farzana; Kibriya, Muhammad G; Ahsan, Habibul; Pierce, Brandon L

    2018-01-01

    Leucocyte telomere length (TL) is a potential biomarker of ageing and risk for age-related disease. Leucocyte TL is heritable and shows substantial differences by race/ethnicity. Recent genome-wide association studies (GWAS) report ~10 loci harbouring SNPs associated with leucocyte TL, but these studies focus primarily on populations of European ancestry. This study aims to enhance our understanding of genetic determinants of TL across populations. We performed a GWAS of TL using data on 5075 Bangladeshi adults. We measured TL using one of two technologies (qPCR or a Luminex-based method) and used standardised variables as TL phenotypes. Our results replicate previously reported associations in the TERC and TERT regions (P=2.2×10 -8 and P=6.4×10 -6 , respectively). We observed a novel association signal in the RTEL1 gene (intronic SNP rs2297439; P=2.82×10 -7 ) that is independent of previously reported TL-associated SNPs in this region. The minor allele for rs2297439 is common in South Asian populations (≥0.25) but at lower frequencies in other populations (eg, 0.07 in Northern Europeans). Among the eight other previously reported association signals, all were directionally consistent with our study, but only rs8105767 ( ZNF208 ) was nominally significant (P=0.003). SNP-based heritability estimates were as high as 44% when analysing close relatives but much lower when analysing distant relatives only. In this first GWAS of TL in a South Asian population, we replicate some, but not all, of the loci reported in prior GWAS of individuals of European ancestry, and we identify a novel second association signal at the RTEL1 locus. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  11. Pulse shape analysis using CsI(Tl) Crystals

    International Nuclear Information System (INIS)

    Silva, J.; Fiori, E.; Loher, B.; Savran, D.; Wirth, R.; Vencelj, M.

    2013-06-01

    The decay time of CsI(Tl) scintillating material consists of more than a single exponential component. The ratio between the intensity of these components varies as a function of the ionizing power of the absorbed particles, such as γ -rays or protons, and the temperature. This property can therefore be used for particle discrimination and for temperature monitoring, using pulse shape analysis. An unsupervised method that uses fuzzy clustering algorithms for particle identification based on pulse shape analysis is presented. The method is applied to discriminate between photon and proton-induced signals in CsI(Tl) scintillator detectors. The first results of a method that uses pulse shape analysis for correcting the temperature-dependent gain effect of the detector are also presented. The method aims at conserving a good energy resolution in a temperature varying environment without the need to measure the temperature of the detector externally (authors)

  12. Statistics and the additive dose method in TL dating

    International Nuclear Information System (INIS)

    Scott, E.M.

    1988-01-01

    Estimation of the palaeo-dose and its associated error in thermoluminescence (TL) dating requires assumptions to be made concerning the error structures of both the TL signal and dose. In this paper, we consider the sensitivity of palaeo-dose estimation to different error structures and describe techniques for estimation of the resultant palaeo-dose errors. We also indicate how the validity of the assumptions may be verified. We have taken the approach that procedures for the analysis of a glow curve at a single temperature must first be proved prior to their inclusion in a full analysis of the glow curves over a series of temperatures. Thus, the paper deals mainly with the analysis of the univariate structure of glow curves, i.e. estimation of the palaeo-dose and error at each temperature, but in the final section of the paper, we discuss briefly the multivariate structure of the results including automatic detection of plateau regions. (author)

  13. Improvement of myocardial perfusion detected by 201Tl scintigraphy on cardiac rehabilitation for patients with coronary artery disease

    International Nuclear Information System (INIS)

    Li, Linxue; Nohara, Ryuji; Makita, Shigeru

    1996-01-01

    The effect of cardiac rehabilitation (mean 70±48 months) on myocardial perfusion was assessed using thallium-201 ( 201 Tl) exercise study in 63 patients with coronary artery disease (CAD). Subjects were those in a rehabilitation group (Rh=42) participating in supervised sports training two to three times per week and the control group (Ct=21) not taking active daily exercise. The interval between two 201 Tl SPECT studies was 19±16 months. After physical training, total duration of the exercise test increased from 443±112 to 536±121 seconds (+19%) in the Rh group, and from 484±129 to 432±115 seconds in the Ct group (-10.7%) (p 2 to 269.8±58 x 10 2 in the Rh group and decreased from 218.7±40 x 10 2 to 216.6±76 x 10 2 (p 201 Tl myocardial perfusion defect on exercise improved more in 54.8% (stress 59.5%, rest 35.7%) in the Rh group than in the Ct group (9.5%, p 201 Tl perfusion defect decreased from 68 (23.1%) to 49 regions (16.7%) of 294 total myocardial regions in the Rh group on exercise. However. it increased from 39 (26.5%) to 44 (29.9%) regions of 147 regions in the Ct group (p<0.01). Thus, cardiac rehabilitation increases exercise tolerance with improvement of myocardial perfusion. suggesting that cardiac rehabilitation is an advisable and effective treatment for patients with ischemic heart disease. (author)

  14. Computerized study with 201Tl of the gold thyroid node

    International Nuclear Information System (INIS)

    Palermo, F.; Saitta, B.; Coghetto, F.; Tiberio, M.; Caldato, L.

    1982-01-01

    Because of its physical and potassium-metabolic characteristics 201 Tl is more suitable than 131 Cs for radioisotopic studies of the cold thyroid nodule, with the further diagnostic possibility of quantitatively assessing intranodular behaviour for a specific differentiation among different kinds of neoformations. Using a gamma-camera on line with a computer data processing device, sequential scintiscans were recorded for the first 20-30 min after i.v. administration of 15-20 μCi/kg of radiothallium; delayed sequences were taken at 40-60 min if intranodular uptake appeared. A quantitative appraisal was made of the differential 201 Tl uptake-ratio between nodule and healthy thyroid tissue (density-index) and the multiparameter analysis of thyroid time/activity curves generated on the relative regions of interest (ROIs). This computerized study, in 120 out of 293 patients submitted to this radiothallium test, has shown a) diagnostic agreement between clinical-histological and radioisotopic findings in 76 out of 79 colloid-cystic or degenerative neoformations, in all 16 malignant and in 23 out of 25 hyperplastic benign nodules; b) significant statistical difference of the density-index in solid versus cystic but not between benign and malignant nodules; c) different 201 Tl kinetics behaviour in different kinds of solid thyroid lesions with a satisfactory statistical difference of the radiothallium nodular dissappearance-index. (orig.) [de

  15. Comparison of 201Tl solution sources in UK hospitals, 2001

    International Nuclear Information System (INIS)

    Baker, M.; Woods, M.

    2001-01-01

    During recent years, concerns have been raised within the nuclear medicine field about the accuracy of activity measurements for 201 Tl. And indeed, NPL calibrations repeatedly indicated that the level of impurities present in such samples and the significant amount of activity adsorbed onto the glass wall of the container could produce erroneous results. In addition, the standard P6 vials, in which 201 Tl solution had been previously supplied, were recently replaced with the new ''10R Type 1 plus'' Schott vials. To assess the magnitude of these effects on the accuracy of clinical measurements of the activity of 201 Tl, an intercomparison exercise was conducted between the National Physical Laboratory (NPL), Nycomed-Amersham (NA) and the UK hospital physics community. The majority of the 273 reported results were within the ± 10 % limit of accuracy that hospitals aim to achieve for diagnosis, biased high. The tendency to overestimate the activity was more evident for syringe measurements. The exercise also revealed that the adsorption losses experienced with P6 vials had been solved by the introduction of the 10R vials, but individual calibrators need to be recalibrated for this new container. (author)

  16. Firing temperature of pottery using TL and OSL techniques

    International Nuclear Information System (INIS)

    Polymeris, G.S.; Sakalis, A.; Papadopoulou, D.; Dallas, G.; Kitis, G.; Tsirliganis, N.C.

    2007-01-01

    Several methods of thermal analysis are used to determine in the laboratory the firing temperature of ancient ceramic sherds. These methods are based primarily on changes of physical characteristics occurring when clay minerals are heated. The luminescence properties of quartz grains in a ceramic matrix also undergo certain changes during firing. The possibility of measuring the sensitivity change (sensitization) of quartz in order to determine the firing temperature of archeological ceramic artifacts was investigated. The sensitivity change was studied for both the thermoluminescence (TL) and the optically stimulated luminescence (OSL) signal for a ceramic sample of known firing temperature. Various segments of the sample were annealed to a different temperature. Subsequently, the initial sensitivity, as well as the thermal and the pre-dose sensitization were measured for both TL and OSL at room temperature as a function of the annealing temperature. The obtained TL glow curves showed different shapes for annealing temperatures above the firing temperature. Thermal and pre-dose sensitizations also exhibited a similar, although less prominent, rise. The OSL signal was analyzed by integrating the raw signal over the initial second of stimulation. The initial sensitivity showed an abrupt change for annealing temperatures around the firing temperature. An alternative approach used for the analysis of the OSL signal involved a full-component resolved sensitization study. The same abrupt change for the initial sensitivity of both the first and second components was observed, as well as, a clear but not very prominent thermal sensitization trend for annealing temperatures above the firing temperature

  17. Nuclear resonance fluorescence of {sup 203,205}Tl

    Energy Technology Data Exchange (ETDEWEB)

    Pfeifer, Fabian; Fritzsche, Matthias; Pietralla, Norbert; Savran, Deniz; Weller, Henry; Zweidinger, Markus [Institut fuer Kernphysik, Technische Universitaet, Darmstadt (Germany); Rusev, Gencho; Tonchev, Anton P.; Tornow, Werner [Triangle Universities Nuclear Laboratory, Duke University, Durham (United States); Zilges, Andreas [Institut fuer Kernphysik, Universitaet Koeln (Germany)

    2009-07-01

    In order to investigate the dipole strength distribution in Thalium isotopes we have studied Nuclear Resonance Fluorescence of a sample composed of natural Thallium (consisting of 30% {sup 203}Tl and 70% {sup 205}Tl). Unpolarized bremsstrahlung with photo energies up to 7.5 MeV was used at the High Intensity Photon Setup (HIPS) at S-DALINAC at the IKP Darmstadt. 24 fluorescent {gamma}-ray transitions were observed, 19 of them for the first time. For the assignment of the polarity of two prominent {gamma}-ray transitions, one at 4.7 MeV and one at 4.9 MeV, the polarized photon beam of the High Intensity {gamma}-ray Source (HI{gamma}S) at Duke University was used. The experiment at HI{gamma}S revealed the existence of a photo-excited state of {sup 205}Tl at an excitation energy of 4.971 MeV that exhibits a transition to the first excited state at 203 keV.

  18. Psoralen plus ultraviolet A (PUVA soaks and UVB TL01 treatment for chronic hand dermatoses

    Directory of Open Access Journals (Sweden)

    Lisbeth Jensen

    2012-02-01

    Full Text Available Chronic eczematous hand dermatoses with and without contact allergies are complex diseases, which makes it a challenge to select the best treatment and obtain an optimal patient experience and a satisfactory treatment result. The aim of this study was to evaluate retrospectively the clinical effect and patient experience of local treatment with psoralen plus ultraviolet A (PUVA soaks and TL01 phototherapy for severe chronic hand dermatoses, and also to evaluate the quality of life for the subgroup of patients with allergic contact dermatitis including Compositae allergy. A retrospective evaluation of results for 94 consecutive patients having received a total of 121 treatment courses with local PUVA soaks or TL01 phototherapy for one of the following diagnoses (n=number of treatment courses: psoriasis (n=19, hyperkeratotic hand eczema (n=27, Pustulosis Palmoplantaris (PPP (n=22, vesicular eczema (n=16, Compositae dermatitis (n=24, and allergic contact dermatitis (n=13. Moreover, semi-structured interviews with 6 selected patients having multiple contact allergies including Compositae allergy were used to evaluate quality of life. As a result, we found that PUVA soaks has good effect in patients with psoriasis and hyperkeratotic hand eczema and local phototherapy for chronic hand dermatoses is a useful treatment option in selected cases.

  19. Smoking and health: association between telomere length and factors impacting on human disease, quality of life and life span in a large population-based cohort under the effect of smoking duration.

    Science.gov (United States)

    Babizhayev, Mark A; Yegorov, Yegor E

    2011-08-01

    Reactive oxygen species (ROS) are of primary importance as they cause damage to lipids, proteins, and DNA either endogenously by cellular mechanism, or through exogenous exposure to environmental injury factors, including oxidation insult factors, such as tobacco smoke. Currently 46.3 million adults (25.7 percent of the population) are smokers. This includes 24 million men (28.1 percent of the total) and more than 22 million women (23.5 percent). The prevalence is highest among persons 25-44 years of age. Cigarette smokers have a higher risk of developing several chronic disorders. These include fatty buildups in arteries, several types of cancer and chronic obstructive pulmonary disease (lung problems). As peripheral leukocytes have been the main target of human telomere research, most of what is known about human telomere dynamics in vivo is based on these cells. Leukocyte telomere length (TL) is a complex trait that is shaped by genetic, epigenetic, and environmental determinants. In this article, we consider that smoking modifies leukocyte TL in humans and contributes to its variability among individuals, although the smoking effect on TL and its relation with other metabolic indices may accelerate biological aging and development of smoking-induced chronic diseases in a large human population-based cohorts with smoking behavior. Recent studies confirmed that individuals with shorter telomeres present a higher prevalence of arterial lesions and higher risk of cardiovascular disease mortality. This study originally suggests that efficient therapeutic protection of TL and structure in response to stresses that are known to reduce TL, such as oxidative damage or inflammation associated with tobacco smoking, would lead to better telomere maintenance. Recently, we have discovered the potential use of telomere-restorative imidazole-containing dipeptide (non-hydrolized carnosine, carcinine) based therapy for better survival of smokers. We conclude that a better

  20. Influence of exposure to pesticides on telomere length in tobacco farmers: A biology system approach.

    Science.gov (United States)

    Kahl, Vivian Francília Silva; da Silva, Juliana; da Silva, Fernanda Rabaioli

    Various pesticides in the form of mixtures must be used to keep tobacco crops pest-free. Recent studies have shown a link between occupational exposure to pesticides in tobacco crops and increased damage to the DNA, mononuclei, nuclear buds and binucleated cells in buccal cells as well as micronuclei in lymphocytes. Furthermore, pesticides used specifically for tobacco crops shorten telomere length (TL) significantly. However, the molecular mechanism of pesticide action on telomere length is not fully understood. Our study evaluated the interaction between a complex mixture of chemical compounds (tobacco cultivation pesticides plus nicotine) and proteins associated with maintaining TL, as well as the biological processes involved in this exposure by System Biology tools to provide insight regarding the influence of pesticide exposure on TL maintenance in tobacco farmers. Our analysis showed that one cluster was associated with TL proteins that act in bioprocesses such as (i) telomere maintenance via telomere lengthening; (ii) senescence; (iii) age-dependent telomere shortening; (iv) DNA repair (v) cellular response to stress and (vi) regulation of proteasome ubiquitin-dependent protein catabolic process. We also describe how pesticides and nicotine regulate telomere length. In addition, pesticides inhibit the ubiquitin proteasome system (UPS) and consequently increase proteins of the shelterin complex, avoiding the access of telomerase in telomere and, nicotine activates UPS mechanisms and promotes the degradation of human telomerase reverse transcriptase (hTERT), decreasing telomerase activity. Copyright © 2016 Elsevier B.V. All rights reserved.

  1. Activation analysis of thallium by /sup 203/Tl(n,2n)/sup 202/Tl reaction in nuclear reactors

    Energy Technology Data Exchange (ETDEWEB)

    Cohen, I M; Resnizky, S M; Baro, G B [Comision Nacional de Energia Atomica, Buenos Aires (Argentina). Gerencia de Radioisotopos y Radiaciones

    1982-01-01

    Two techniques are described for neutron activation analysis of thallium in biological and geological materials, based on /sup 203/Tl(n,2n)/sup 202/Tl reaction in nuclear reactors. Co-precipitation with bismuth sulphide is used as a pre-concentration method of thallium in urine samples, and post-irradiation chemical separation is also performed. The detection limit is 0.5 ..mu..g/l, for 100 ml urine samples. For thallium determination in blendes a radiochemical separation is carried out after the irradiation. An extension of this technique is presented for glass and silicate rocks. Results for seven blende samples from different places of Argentina are shown. Analysis of two reference materials, the 614 glass from the National Bureau of Standards and the granodiorite GSP-1 from the U.S. Geological Survey were also performed. The results are in very good agreement with the certified or estimated values.

  2. Telomere length, ATM mutation status and cancer risk in Ataxia-Telangiectasia families.

    Science.gov (United States)

    Renault, Anne-Laure; Mebirouk, Noura; Cavaciuti, Eve; Le Gal, Dorothée; Lecarpentier, Julie; d'Enghien, Catherine Dubois; Laugé, Anthony; Dondon, Marie-Gabrielle; Labbé, Martine; Lesca, Gaetan; Leroux, Dominique; Gladieff, Laurence; Adenis, Claude; Faivre, Laurence; Gilbert-Dussardier, Brigitte; Lortholary, Alain; Fricker, Jean-Pierre; Dahan, Karin; Bay, Jacques-Olivier; Longy, Michel; Buecher, Bruno; Janin, Nicolas; Zattara, Hélène; Berthet, Pascaline; Combès, Audrey; Coupier, Isabelle; Hall, Janet; Stoppa-Lyonnet, Dominique; Andrieu, Nadine; Lesueur, Fabienne

    2017-10-01

    Recent studies have linked constitutive telomere length (TL) to aging-related diseases including cancer at different sites. ATM participates in the signaling of telomere erosion, and inherited mutations in ATM have been associated with increased risk of cancer, particularly breast cancer. The goal of this study was to investigate whether carriage of an ATM mutation and TL interplay to modify cancer risk in ataxia-telangiectasia (A-T) families.The study population consisted of 284 heterozygous ATM mutation carriers (HetAT) and 174 non-carriers (non-HetAT) from 103 A-T families. Forty-eight HetAT and 14 non-HetAT individuals had cancer, among them 25 HetAT and 6 non-HetAT were diagnosed after blood sample collection. We measured mean TL using a quantitative PCR assay and genotyped seven single-nucleotide polymorphisms (SNPs) recurrently associated with TL in large population-based studies.HetAT individuals were at increased risk of cancer (OR = 2.3, 95%CI = 1.2-4.4, P = 0.01), and particularly of breast cancer for women (OR = 2.9, 95%CI = 1.2-7.1, P = 0.02), in comparison to their non-HetAT relatives. HetAT individuals had longer telomeres than non-HetAT individuals (P = 0.0008) but TL was not associated with cancer risk, and no significant interaction was observed between ATM mutation status and TL. Furthermore, rs9257445 (ZNF311) was associated with TL in HetAT subjects and rs6060627 (BCL2L1) modified cancer risk in HetAT and non-HetAT women.Our findings suggest that carriage of an ATM mutation impacts on the age-related TL shortening and that TL per se is not related to cancer risk in ATM carriers. TL measurement alone is not a good marker for predicting cancer risk in A-T families. © The Author 2017. Published by Oxford University Press.

  3. Exploration of GaInTlP and related Tl-containing III-V alloys for photovoltaics

    International Nuclear Information System (INIS)

    Friedman, D. J.; Kurtz, Sarah R.; Kibbler, A. E.

    1999-01-01

    This paper discusses the results of an attempt to grow GaInTlP for application as a 1-eV material for the third junction of a GaInP/GaAs/3rd-junction high-efficiency solar cell. Although early indications from the literature were promising, we are unable to produce crystalline homogeneous material, and so we conclude that this material is not a promising candidate for such applications as photovoltaics

  4. Development of surgical gamma probes with TlBr semiconductors and CsI(Tl) scintillators crystals

    International Nuclear Information System (INIS)

    Costa, Fabio Eduardo da

    2006-01-01

    Radio guided surgery, using probes with radiation detectors, has been prominence in the medical area in the last decade. This technique consists in injecting a radioactive substance to concentrate in tumour and assist the localization during the surgical procedure. The radio guided surgeries allowing the identification of lymph node has revolutioned the behavior of tumour in initial stadium when are being spread by lymphatic way. The conditions imposed to the surgery due the proximity between some lymph nodes, demands of the probes, a small diameters and capacity of individual identification of these lymph nodes radiolabelled by a specific tracer. The international market supplies these probes with CdTe semiconductors and scintillators, but there is some time lack a promptly technical assistance in the Brazilian market. This work developed probes with national technology, using CsI(Tl) scintillators crystals and, in substitution to CdTe crystals semiconductors, the TlBr crystal, that is a new semiconductor detector in a world-wide development, with advantages in relation to the CdTe. Both crystals have been grown in IPEN. All the necessary electronics, specially, the preamplifier, that was also a restrictive factor for development of these types of probe in the country, have been developed with components found in the national market. Systematic measures of spatial resolution, spatial selectivity, maximum sensitivity and quality of the shielding have been carried the probes development. The results have shown that the probes, one with the CsI(Tl) crystal and another with TlBr semiconductor presented the requested performance in the international literature for radio guided probes. (author)

  5. Exploring the thermoelectric and magnetic properties of uranium selenides: Tl2Ag2USe4 and Tl3Cu4USe6

    International Nuclear Information System (INIS)

    Azam, Sikander; Khan, Saleem Ayaz; Din, Haleem Ud; Khenata, Rabah; Goumri-Said, Souraya

    2016-01-01

    The electronic, magnetic and thermoelectric properties of Tl 2 Ag 2 USe 4 and Tl 3 Cu 4 USe 6 compounds were investigated using the full potential linear augmented plane wave (FP-LAPW) method based on the density functional theory (DFT). The exchange correlation was treated with the generalized gradient approximation plus optimized effective Hubbard parameter and spin–orbit coupling (GGA+U+SOC). The present uranium selenides show narrow direct energy band gap values of 0.7 and 0.875 eV for Tl 2 Ag 2 USe 4 and Tl 3 Cu 4 USe 6 respectively. For both selenides U-d/f states are responsible for electrical transport properties. Uranium atoms were the most contributors in the magnetic moment compared to other atoms and show ferromagnetic nature. The spin density isosurfaces show the polarization of neighboring atoms of Uranium, such as silver/copper and selenium. Thermoelectric calculations reveal that Tl 3 Cu 4 USe 6 is more suitable for thermoelectric device applications than Tl 2 Ag 2 USe 4 . - Highlights: • Electronic, magnetic and thermoelectric properties of uranium selenides are investigated with DFT. • They show a narrow direct energy band gap of 0.7 and 0.875 eV. • U-d/f states are responsible for electrical transport properties. • Tl 3 Cu 4 USe 6 is more suitable for thermoelectric device applications than Tl 2 Ag 2 USe 4 .

  6. Gamma-radiation-induced change in the activation energy of TL traps in LiRbSO[sub 4]:Tl

    Energy Technology Data Exchange (ETDEWEB)

    Kassem, M.E.; El-Kolaly, M.A.; Al-Houty, L.I. (Qatar Univ., Doha (Qatar). Dept. of Physics)

    1994-06-01

    Thermoluminescence (TL) measurements were carried out for pure and doped LiRbSO[sub 4], with different concentrations of thallium (Tl). The glow-curve range of measurement is between room temperature up to 300[sup o]C. The radiation absorbed dose is in the range 56-3.2 x 10[sup 5] Gy. The results show that both pure and doped samples have glow peak temperatures that are dose dependent, and vary between 70-80[sup o]C and 140-170[sup o]C for pure and doped samples respectively. Doped samples display double peaks that increase with dopant concentration up to about 0.7% wt. The second peak which occurs at high temperature increases linearly with dose up to 4500 Gy. From the results it is proposed that LiRbSO[sub 4] doped with 0.7% Tl can be used for dosimetric purposes in this range. The activation energies of structural transitions are estimated and the results are discussed on the basis of radiation-induced stable dipoles in the random field system. (Author).

  7. Tl-201 and Tc-99m-DTPA neuro-SPECT in cerebral radiation necrosis

    International Nuclear Information System (INIS)

    Cleto, E.M. Jr.; Holmes, R.A.; Gumerlock, M.K.; Cabeen, M.; Logan, K.W.; Hoffman, T.J.

    1992-01-01

    The results in 3 cases of radiation necrosis demonstrate that by using both radionuclides Tl-201 and Tc-99m-DTPA, one can provide a semi-quantitative method to differentiate recurrent tumor from radiation necrosis. Focally increased cerebral Tl-201 activity in irradiated brain tumor patients is not specific for tumor recurrence, but when used in combination with DTPA, one is able to estimate the amount of Tl-201 activity resulting from increased blood-brain barrier permeability. If the average Tl-201 index is less than the average Tc-99m-DTPA index it suggests that the increased Tl-201 activity results primarily from blood-brain barrier breakdown. Tc-99m-DTPA SPECT, in addition to Tl-201 SPECT, or serial Tl-201 SPECT imaging may increase the accuracy of brain scintigraphy in differentiating radiation necrosis from tumor recurrence. To verify these preliminary findings, we are in the process of analyzing additional SPECT data on 9 more patients with malignant brain tumors. Using a slightly different method of quantifying Tl- 201/Tc-99m-DTPA ratios (computing the ratio of intralesional Tl-201 or Tc-99m-DTPA activity compared to adjacent scalp activity), patients with tumor recurrence have higher Tl-201/Tc-99m-DTPA ratios compared to those with radiation necrosis (verbal communication with Dr. Mary K. Gumerlock). (orig.) [de

  8. Electronic structure of TlBa2CaCu2O7-δ

    Science.gov (United States)

    Vasquez, R. P.; Novikov, D. L.; Freeman, A. J.; Siegal, M. P.

    1997-06-01

    The core levels of TlBa2CaCu2O7-δ (Tl-1212) epitaxial films have been measured with x-ray photoelectron spectroscopy (XPS). The valence electronic structure has been determined using the full-potential linear muffin-tin-orbital band-structure method and measured with XPS. The calculations show that a van Hove singularity (VHS) lies above the Fermi level (EF) for the stoichiometric compound (δ=0), while for 50% oxygen vacancies in the Tl-O layer (δ=0.5) EF is in close proximity to the VHS. Samples annealed in nitrogen (to reduce the hole overdoping by the removal of oxygen) exhibit higher core-level binding energies and a higher Tc, consistent with a shift of EF closer to the VHS. Comparisons are made to the core levels and valence bands of Tl2Ba2CaCu2O8+δ (Tl-2212) and HgBa2CaCu2O6+δ (Hg-1212). The similarity of the Cu 2p3/2 spectra for Tl-1212 and Tl-2212 indicates that the number of Tl-O layers has little effect on the Cu-O bonding. However, the Tl-1212 and Hg-1212 Cu 2p3/2 signals exhibit differences which suggest that the replacement of Tl3+ with Hg2+ results in a decrease in the O 2p-->Cu 3d charge-transfer energy and differences in the probabilities of planar vs apical oxygen charge transfer and/or Zhang-Rice singlet-state formation. Differences between the Tl-1212 and the Tl-2212 and Hg-1212 measured valence bands are consistent with the calculated Cu 3d and (Tl,Hg) 6s/5d partial densities of states.

  9. Electronic structure of TlBa2CaCu2O7-δ

    International Nuclear Information System (INIS)

    Vasquez, R.P.; Novikov, D.L.; Freeman, A.J.; Siegal, M.P.

    1997-01-01

    The core levels of TlBa 2 CaCu 2 O 7-δ (Tl-1212) epitaxial films have been measured with x-ray photoelectron spectroscopy (XPS). The valence electronic structure has been determined using the full-potential linear muffin-tin-orbital band-structure method and measured with XPS. The calculations show that a van Hove singularity (VHS) lies above the Fermi level (E F ) for the stoichiometric compound (δ=0), while for 50% oxygen vacancies in the Tl-O layer (δ=0.5) E F is in close proximity to the VHS. Samples annealed in nitrogen (to reduce the hole overdoping by the removal of oxygen) exhibit higher core-level binding energies and a higher T c , consistent with a shift of E F closer to the VHS. Comparisons are made to the core levels and valence bands of Tl 2 Ba 2 CaCu 2 O 8+δ (Tl-2212) and HgBa 2 CaCu 2 O 6+δ (Hg-1212). The similarity of the Cu 2p 3/2 spectra for Tl-1212 and Tl-2212 indicates that the number of Tl-O layers has little effect on the Cu-O bonding. However, the Tl-1212 and Hg-1212 Cu 2p 3/2 signals exhibit differences which suggest that the replacement of Tl 3+ with Hg 2+ results in a decrease in the O 2p→Cu 3d charge-transfer energy and differences in the probabilities of planar vs apical oxygen charge transfer and/or Zhang-Rice singlet-state formation. Differences between the Tl-1212 and the Tl-2212 and Hg-1212 measured valence bands are consistent with the calculated Cu 3d and (Tl,Hg) 6s/5d partial densities of states. copyright 1997 The American Physical Society

  10. Age-dependent associations between telomere length and environmental conditions in roe deer.

    Science.gov (United States)

    Wilbourn, Rachael V; Froy, Hannah; McManus, Marie-Christina; Cheynel, Louise; Gaillard, Jean-Michel; Gilot-Fromont, Emmanuelle; Regis, Corinne; Rey, Benjamin; Pellerin, Maryline; Lemaître, Jean-François; Nussey, Daniel H

    2017-09-01

    Telomere length (TL) represents a promising biomarker of overall physiological state and of past environmental experiences, which could help us understand the drivers of life-history variation in natural populations. A growing number of studies in birds suggest that environmental stress or poor environmental conditions are associated with shortened TL, but studies of such relationships in wild mammals are lacking. Here, we compare leucocyte TL from cross-sectional samples collected from two French populations of roe deer which experience different environmental conditions. We found that, as predicted, TL was shorter in the population experiencing poor environmental conditions but that this difference was only significant in older individuals and was independent of sex and body mass. Unexpectedly, the difference was underpinned by a significant increase in TL with age in the population experiencing good environmental conditions, while there was no detectable relationship with age in poor conditions. These results demonstrate both the environmental sensitivity and complexity of telomere dynamics in natural mammal populations, and highlight the importance of longitudinal data to disentangle the within- and among-individual processes that generate them. © 2017 The Authors.

  11. Cost-effectiveness of exercise 201Tl myocardial SPECT in patients with chest pain assessed by decision-tree analysis

    International Nuclear Information System (INIS)

    Kosuda, Shigeru; Momiyama, Yukihiko; Ohsuzu, Fumitaka; Kusano, Shoichi; Ichihara, Kiyoshi

    1999-01-01

    To evaluate the potential cost-effectiveness of exercise 201 Tl myocardial SPECT in outpatients with angina-like chest pain, we developed a decision-tree model which comprises three 1000-patients groups, i.e., a coronary arteriography (CAG) group, a follow-up group, and a SPECT group, and total cost and cardiac events, including cardiac deaths, were calculated. Variables used for the decision-tree analysis were obtained from references and the data available at out hospital. The sensitivity and specificity of 201 Tl SPECT for diagnosing angina pectoris, and its prevalence were assumed to be 95%, 85%, and 33%, respectively. The mean costs were 84.9 x 10 4 yen/patient in the CAG group, 30.2 x 10 4 yen/patient in the follow-up group, and 71.0 x 10 4 yen/patient in the SPECT group. The numbers of cardiac events and cardiac deaths were 56 and 15, respectively in the CAG group, 264 and 81 in the follow-up group, and 65 and 17 in the SPECT group. SPECT increases cardiac events and cardiac deaths by 0.9% and 0.2%, but it reduces the number of CAG studies by 50.3%, and saves 13.8 x 10 4 yen/patient, as compared to the CAG group. In conclusion, the exercise 201 Tl myocardial SPECT strategy for patients with chest pain has the potential to reduce health care costs in Japan. (author)

  12. Serial assessment of left ventricular function in various patient groups with Tl-201 gated myocardial perfusion SPECT

    International Nuclear Information System (INIS)

    Wei Lingge; Kadoya, Masumi; Momose, Mitsuhiro; Kurozumi, Masahiro; Matsushita, Tsuyoshi; Yamada, Akira

    2007-01-01

    The present study was performed to assess stress-related left ventricular (LV) function variations in various patient groups and to determine if they were affected by sex or the type of stress experienced. We used thallium (Tl)-201 gated myocardial perfusion single-photon emission computed tomography (SPECT) for the analysis. A total of 270 patients were examined by electrocardiography-gated myocardial perfusion SPECT imaging to assess LV function. After injection of Tl-201 at a dose of 111 MBq at peak stress, SPECT scans were acquired at 10 min (after stress) and 3 h (rest) after injection on a three-headed camera. In the normal perfusion group, the mean LV ejection fraction (LVEF) was significantly higher, and both the end-diastolic volume index (EDVI) and end-systolic volume index (ESVI) were significantly lower in women than in men (P<0.05). Poststress stunning occurred in 29 of 98 patients (30.0%) in the ischemia group and in 42 of 90 patients (46.7%) in the fixed group. There was a significant difference in poststress stunning between bicycle ergometer stress and dipyridamole stress (P<0.05). In patients with normal perfusion, LVEF, EDVI, and ESVI determined by gated Tl-201 SPECT should be corrected for sex. In addition, the influence of the type of stress should be considered when assessing stress-related LV function variations. (author)

  13. Clinical usefulness of technetium-99m pyrophosphate and Tl-201 myocardial imaging for the estimation of myocardial infarction

    Energy Technology Data Exchange (ETDEWEB)

    Suzuki, Akio; Sato, Akihiko; Miyakoda, Hiroyuki; Watanabe, Toshiya; Itatsu, Hidetaka; Ueda, Osamu; Sakurai, Kuniteru; Kawai, Naoki; Sotobata, Iwao

    1985-04-01

    A correlative study was performed between the infarct size estimated by either technetium-99 pyrophosphate (Tc-PYP) or Tl-201 myocardial imaging, and the cumulative total creatinine phosphokinase activity (..sigma..CPK) or left ventricular ejection fraction (LVEF) in 40 patients with acute myocardial infarction. Tc-PYP infarct area (TcIA) and mean Tl-201 uptake ratio (MUR) were calculated as indices of myocardial infarct size. LVEF was evaluated by first pass method using Tc-PYP in the acute phase of myocardial infraction. In 23 patients with anterior myocardial infarction, a significant correlation was shown between either TcIA or anterior-wall MUR and ..sigma..CPK (r=0.81 and r=-0.69, respectively) and also between either TcIA or anterior-wall MUR and LVEF (r=-0.84 and r=0.80, respectively). In 17 patients with inferior myocardial infarction without additional involvement of right ventricular wall, inferior-wall MUR correlated with ..sigma..CPK (r=-0.74). No statically significant correlation was shown between TcIA and ..sigma..CPK, and also between either TcIA or inferior-wall MUR and LVEF. In conclusion, the infarct size estimated with Tc-PYP or Tl-201 myocardial imaging could be a useful clinical indicator of the severity of acute myocardial infarction especially in anterior wall. (author).

  14. Composite detector for mixed radiations based on CsI(Tl) and dispersions of small ZnSe(Te) crystals

    International Nuclear Information System (INIS)

    Ryzhikov, V.; Gal'chinetskii, L.; Katrunov, K.; Lisetskaya, E.; Gavriluk, V.; Zelenskaya, O.; Starzhynskiy, N.; Chernikov, V.

    2005-01-01

    A new large area detector of high-energy X-ray and β-radiation has been designed and studied. A composite material based on small-crystalline ZnSe(Te) was applied onto the wide surface of a light guide. An experimental specimen has been prepared, which showed β-sensitivity C β =5.5cm 2 . The spectrograms of a 90 Sr+ 90 Y β-source obtained with the specimen under study make it possible to evaluate the age of the source by the ratio of low- and high-energy regions of the spectrum. The combined detector (CD) comprises a single crystalline plate of ZnSe(Te) placed onto the output window of a scintillating transparent light guide made of CsI(Tl) in the shape of a truncated pyramid. The CsI(Tl) light guide is used to create an additional channel for detection of γ-radiation, as well as for protecting the photodiode from the penetrating radiation. It is shown that introduction of the light guide does not worsen the energy resolution characteristics of ZnSe(Te). Separate detection of α- and γ-radiation has been achieved under simultaneous excitation by 239 Pu (ZnSe(Te), R α =6%) and 241 Am (CsI(Tl), R γ =20%). The use of selective optical filters allows separation of the peaks of total absorption (p.t.a.) in the case of their superposition

  15. Distribution of chemical elements in soils and stream sediments in the area of abandoned Sb–As–Tl Allchar mine, Republic of Macedonia

    Energy Technology Data Exchange (ETDEWEB)

    Bačeva, Katerina [Institute of Chemistry, Faculty of Natural Sciences and Mathematics, Ss. Cyril and Methodius University, POB 162, 1000 Skopje (Macedonia, The Former Yugoslav Republic of); Stafilov, Trajče, E-mail: trajcest@pmf.ukim.mk [Institute of Chemistry, Faculty of Natural Sciences and Mathematics, Ss. Cyril and Methodius University, POB 162, 1000 Skopje (Macedonia, The Former Yugoslav Republic of); Šajn, Robert [Geological Survey of Slovenia, Ljubljana (Slovenia); Tănăselia, Claudiu [INCDO-INOE 2000 Research Institute for Analytical Instrumentation (ICIA), Cluj-Napoca (Romania); Makreski, Petre [Institute of Chemistry, Faculty of Natural Sciences and Mathematics, Ss. Cyril and Methodius University, POB 162, 1000 Skopje (Macedonia, The Former Yugoslav Republic of)

    2014-08-15

    The aim of this study was to investigate the distribution of some toxic elements in topsoil and subsoil, focusing on the identification of natural and anthropogenic element sources in the small region of rare As–Sb–Tl mineralization outcrop and abandoned mine Allchar known for the highest natural concentration of Tl in soil worldwide. The samples of soil and sediments after total digestion were analyzed by inductively coupled plasma–mass spectrometry (ICP–MS) and inductively coupled plasma–atomic emission spectrometry (ICP–AES). Factor analysis (FA) was used to identify and characterize element associations. Six associations of elements were determined by the method of multivariate statistics: Rb–Ta–K–Nb–Ga–Sn–Ba–Bi–Li–Be–(La–Eu)–Hf–Zr–Zn–In–Pd–Ag–Pt–Mg; Tl–As–Sb–Hg; Te–S–Ag–Pt–Al–Sc–(Gd–Lu)–Y; Fe–Cu–V–Ge–Co–In; Pd–Zr–Hf–W–Be and Ni–Mn–Co–Cr–Mg. The purpose of the assessment was to determine the nature and extent of potential contamination as well as to broadly assess possible impacts to human health and the environment. The results from the analysis of the collected samples in the vicinity of the mine revealed that As and Tl elements have the highest median values. Higher median values for Sb are obviously as a result of the past mining activities and as a result of area surface phenomena in the past. - Highlights: • Soil and river sediments were analyzed from Sb–As–Tl Allchar locality. • An increased content of certain toxic elements for environment was determined. • Highest As and Tl contents are obtained in the close vicinity of Allchar mine. • River sediments portray 160 times higher content of Sb than EU values. • The results classify Allchar as probably the highest natural Tl-deposit worldwide.

  16. Pulse and integral optically stimulated luminescence (OSL). Similarities and dissimilarities to thermoluminescence (TL) dose dependence and dose-rate effects

    International Nuclear Information System (INIS)

    Chen, R.; Leung, P.L.

    2000-01-01

    Optically stimulated luminescence (OSL) and thermoluminescence (Tl) are two possible methods to monitor the absorbed radiation in solid samples, and therefore are utilized for dosimetry. For this application, two properties are desirable, namely, linear dose dependence of the measured quantity and dose-rate independence. For Tl, different kinds of super linear dose dependence have been reported in the literature in different materials, and in some cases, dose-rate dependence has also been found. These have been explained as being the result of competition. In OSL, some recent works reported on super linear dose dependence in annealed samples. In the present work, we explain the possible occurrence of these phenomena in OSL by solving numerically the relevant rate equations governing the process during irradiation, relaxation and read-out (heating or light stimulation). The results show that for short pulse OSL, quadratic dose dependence can be expected when only one trapping state and one kind of recombination center are involved and when the excitation starts with empty traps and centers. With the short pulse OSL, the calculation also reveals a possible dose-rate effect. Under the same circumstances, the area under the OSL curve depends linearly on the dose. The dependence of the whole area under the OSL curve on the dose is shown to be super linear when a disconnected trapping state or radiationless center take part in the process. Also, dose-rate effect can be expected in these cases, although no experimental effect of this sort has been reported so far. In pulse OSL, the analogy is made between the measured intensity and the initial rise range of non-first order Tl, whereas for the total area OSL, there is a nearly full analogy with the dose behavior of the Tl maximum. (Author)

  17. Influence of exposure to pesticides on telomere length in tobacco farmers: A biology system approach

    Energy Technology Data Exchange (ETDEWEB)

    Kahl, Vivian Francília Silva [Laboratory of Genetic Toxicology, PPGBioSaúde and PPGGTA, Lutheran University of Brazil (ULBRA), Canoas, RS (Brazil); Silva, Juliana da, E-mail: juliana.silva@ulbra.br [Laboratory of Genetic Toxicology, PPGBioSaúde and PPGGTA, Lutheran University of Brazil (ULBRA), Canoas, RS (Brazil); Rabaioli da Silva, Fernanda, E-mail: fernanda.silva@unilasalle.edu.br [Master’s Degree in Environmental Impact Evaluation, Centro Universitário La Salle, Canoas, RS (Brazil)

    2016-09-15

    Highlights: • Exposure to pesticides in tobacco fields is related to shorten telomere length. • The molecular mechanism of pesticide on telomere length is not fully understood. • Pesticides inhibit ubiquitin proteasome system. • Nicotine activates ubiquitin proteasome system. • Pesticides and nicotine regulate telomere length. - Abstract: Various pesticides in the form of mixtures must be used to keep tobacco crops pest-free. Recent studies have shown a link between occupational exposure to pesticides in tobacco crops and increased damage to the DNA, mononuclei, nuclear buds and binucleated cells in buccal cells as well as micronuclei in lymphocytes. Furthermore, pesticides used specifically for tobacco crops shorten telomere length (TL) significantly. However, the molecular mechanism of pesticide action on telomere length is not fully understood. Our study evaluated the interaction between a complex mixture of chemical compounds (tobacco cultivation pesticides plus nicotine) and proteins associated with maintaining TL, as well as the biological processes involved in this exposure by System Biology tools to provide insight regarding the influence of pesticide exposure on TL maintenance in tobacco farmers. Our analysis showed that one cluster was associated with TL proteins that act in bioprocesses such as (i) telomere maintenance via telomere lengthening; (ii) senescence; (iii) age-dependent telomere shortening; (iv) DNA repair (v) cellular response to stress and (vi) regulation of proteasome ubiquitin-dependent protein catabolic process. We also describe how pesticides and nicotine regulate telomere length. In addition, pesticides inhibit the ubiquitin proteasome system (UPS) and consequently increase proteins of the shelterin complex, avoiding the access of telomerase in telomere and, nicotine activates UPS mechanisms and promotes the degradation of human telomerase reverse transcriptase (hTERT), decreasing telomerase activity.

  18. Influence of exposure to pesticides on telomere length in tobacco farmers: A biology system approach

    International Nuclear Information System (INIS)

    Kahl, Vivian Francília Silva; Silva, Juliana da; Rabaioli da Silva, Fernanda

    2016-01-01

    Highlights: • Exposure to pesticides in tobacco fields is related to shorten telomere length. • The molecular mechanism of pesticide on telomere length is not fully understood. • Pesticides inhibit ubiquitin proteasome system. • Nicotine activates ubiquitin proteasome system. • Pesticides and nicotine regulate telomere length. - Abstract: Various pesticides in the form of mixtures must be used to keep tobacco crops pest-free. Recent studies have shown a link between occupational exposure to pesticides in tobacco crops and increased damage to the DNA, mononuclei, nuclear buds and binucleated cells in buccal cells as well as micronuclei in lymphocytes. Furthermore, pesticides used specifically for tobacco crops shorten telomere length (TL) significantly. However, the molecular mechanism of pesticide action on telomere length is not fully understood. Our study evaluated the interaction between a complex mixture of chemical compounds (tobacco cultivation pesticides plus nicotine) and proteins associated with maintaining TL, as well as the biological processes involved in this exposure by System Biology tools to provide insight regarding the influence of pesticide exposure on TL maintenance in tobacco farmers. Our analysis showed that one cluster was associated with TL proteins that act in bioprocesses such as (i) telomere maintenance via telomere lengthening; (ii) senescence; (iii) age-dependent telomere shortening; (iv) DNA repair (v) cellular response to stress and (vi) regulation of proteasome ubiquitin-dependent protein catabolic process. We also describe how pesticides and nicotine regulate telomere length. In addition, pesticides inhibit the ubiquitin proteasome system (UPS) and consequently increase proteins of the shelterin complex, avoiding the access of telomerase in telomere and, nicotine activates UPS mechanisms and promotes the degradation of human telomerase reverse transcriptase (hTERT), decreasing telomerase activity.

  19. Phase equilibria in TlX-Cd(Zn)X (X-S, Se, Te) systems

    International Nuclear Information System (INIS)

    Gusejnov, F.Kh.; Babanly, M.B.; Kuliev, A.A.

    1982-01-01

    The methods of DTA, RPA and measurement of the alloys microhardness have been used to investigate the phase equilibria in the TlX-Zn(Cd)X systems. It is established that the TlZn(Cd)X 2 compounds, the presence of which is mentioned in the literature earlier, do not form in these systems. The TlSe-Zn(Cd)Se systems apply to the simple eutectic type and characterized by digenerated eutectic near the TlSe. Thermodynamical analysis of the liquidus of the TlSe-CdSe and TlTe-Zn(Cd)Te systems in approximation of the regular solutions, taking into account the dissociation of tallium chalcogenides in liquid phase, is made

  20. TL and ESR based identification of gamma-irradiated frozen fish using different hydrolysis techniques

    Science.gov (United States)

    Ahn, Jae-Jun; Akram, Kashif; Shahbaz, Hafiz Muhammad; Kwon, Joong-Ho

    2014-12-01

    Frozen fish fillets (walleye Pollack and Japanese Spanish mackerel) were selected as samples for irradiation (0-10 kGy) detection trials using different hydrolysis methods. Photostimulated luminescence (PSL)-based screening analysis for gamma-irradiated frozen fillets showed low sensitivity due to limited silicate mineral contents on the samples. Same limitations were found in the thermoluminescence (TL) analysis on mineral samples isolated by density separation method. However, acid (HCl) and alkali (KOH) hydrolysis methods were effective in getting enough minerals to carry out TL analysis, which was reconfirmed through the normalization step by calculating the TL ratios (TL1/TL2). For improved electron spin resonance (ESR) analysis, alkali and enzyme (alcalase) hydrolysis methods were compared in separating minute-bone fractions. The enzymatic method provided more clear radiation-specific hydroxyapatite radicals than that of the alkaline method. Different hydrolysis methods could extend the application of TL and ESR techniques in identifying the irradiation history of frozen fish fillets.

  1. TL response to quartz and aluminum oxide grain for α-irradiation

    International Nuclear Information System (INIS)

    Pan Baolin; Wei Mingjian; Li Dongxu; Liu Zhaowen; Liu Chao; Zhao Shiyuan

    2009-01-01

    Thermoluminescence (TL) response for an α-ray irradiation system ( 241 Am) was examined with quartz grains of 11-40 μm. Quartz grains of different sizes, i.e. 137 Cs), before they were irradiated to different doses by the α-ray irradiation system. TL response to the quartz grain samples was measured. TL response of the quartz grains smaller than 4 μm and 11-40 μm to α-ray irradiation is the best, as the α-rays cannot penetrate quartz larger than 40 μm. The TL response characteristic is related with quartz grain surface area. TL responses to α-irradiation of 11-40 μm quartz and aluminum oxide grains were compared. The α-irradiation TL response of aluminum oxide (330 degree C) is better than the quartz (375 degree C). (authors)

  2. Differential diagnosis of thyroid diseases with 131I and 201TlCl scintigraphy

    International Nuclear Information System (INIS)

    Kumano, Machiko; Ishida, Osamu

    1979-01-01

    Scintigraphic study with 131 I and 201 TlCl was performed on the differential diagnosis of various kinds of thyroid disease. When thyroid nodules are cold by scintigraphy with 131 I and hot with 201 TlCl, the lesions were proved to be solid tumor, that is, mostly follicular adenoma and carcinoma, and also most probably chronic thyroiditis. Accumulation of 201 TlCl, however, is not observed in cystic lesions, and is very high with high frequency in metastatic lesion of the lymph nodes as well as the thyroid cancer, especially in well differentiated follicular carcinoma. Therefore 201 TlCl was very useful to confirm the metastatic tumors from the thyroid cancer. These features in accumulation of 131 I and 201 TlCl in thyroid disease suggest the imaging technique with 201 TlCl combined with 131 I seem to provide more pathological information on the thyroid and metastatic lesions. (author)

  3. Radiation exposure around patients after 201Tl-myocardial scintigraphy

    International Nuclear Information System (INIS)

    Kurtaran, A.; Preitfellner, J.; Kohoutek, D.; Tousek, A.; Virgolini, I.; Havlik, E.

    1997-01-01

    Aim: It was the aim of the study to assess the additional radiation exposure to patients, attendents and nurses by patients who are undergoing nuclear medicine investigations (myocardial scintigraphy) with 201 Tl-chloride ( 201 Tl-Cl). Methode: In 16 cases the dose rates at 0.5, 1 and 2 m distance from patients were measured at 0.5, 1.5, 3-4 and 24, in some cases until 370 h after administration of 100±10 MBq 201 Tl-Cl. From the time courses of the dose rates around the patients the possible radiation exposure of other persons were estimated. Results: The initial values of the dose rate were 3.82 μSv/h at 0.5 m, 1.18 μSv/h at 1 m and 0.30 μSv/h at 2 m distance from the patients respectively. The dose rates were decreasing following a monoexponential course with an effective half-life of 60 h. The maximum doses to other persons at 1 m distance from the patients were determined by considering three scenarios. The values were 13 μSv in the waiting room, 26 μSv for nurses working in the ward and 105 μSv for persons living in the same household. Conclusion: Even at very restrictive assumptions the doses were far below the maximum permissible dose to non-radiation workers set by radiation protection regulations (1.5 mSv per year). (orig.) [de

  4. Dosimetric characteristics of LKB:Cu,P solid TL detector

    International Nuclear Information System (INIS)

    Hashim, S.; Alajerami, Y.S.M.; Ghoshal, S.K.; Saleh, M.A.; Saripan, M.I.; Kadir, A.B.A.; Bradley, D.A.; Alzimami, K.

    2014-01-01

    The dosimetric characteristics of newly developed borate glass dosimeter modified with lithium and potassium carbonate (LKB) and co-doped with CuO and NH 4 H 2 PO 4 are reported. Broad peaks in the absence of any sharp peak confirms the amorphous nature of the prepared glass. A simple glow curve of Cu doped sample is observed with a single prominent peak (T m ) at 220 °C. The TL intensity response shows an enhancement of ∼100 times due to the addition of CuO (0.1 mol%) to LKB compound. A further enhancement of the intensity by a factor of 3 from the addition of 0.25 mol% NH 4 H 2 PO 4 as a co-dopant impurity is attributed to the creation of extra electron traps with consequent increase in energy transfer of radiation recombination centers. The TL yield performance of LKB:Cu,P with Z eff ≈8.92 is approximately seventeen times less sensitive compared to LiF:Mg,Ti (TLD-100). The proposed dosimeter shows good linearity up to 10 3 Gy, minimal fading and photon energy independence. These attractive features offered by our dosimeter is expected to pave the way towards dosimetric applications. - Highlights: • The NH 4 H 2 PO 4 impurities are cross linked with the CuO defect. • The addition of NH 4 H 2 PO 4 as a co-dopant improved the TL intensity by a factor of 3. • The proposed dosimeter shows good linearity up to 10 3 Gy. • Minimal fading and photon energy independence were observed

  5. Model-based visual tracking the OpenTL framework

    CERN Document Server

    Panin, Giorgio

    2011-01-01

    This book has two main goals: to provide a unifed and structured overview of this growing field, as well as to propose a corresponding software framework, the OpenTL library, developed by the author and his working group at TUM-Informatik. The main objective of this work is to show, how most real-world application scenarios can be naturally cast into a common description vocabulary, and therefore implemented and tested in a fully modular and scalable way, through the defnition of a layered, object-oriented software architecture.The resulting architecture covers in a seamless way all processin

  6. Design and manufacture of TL analyser by using the microcomputer

    International Nuclear Information System (INIS)

    Doh, Sih Hong; Woo, Chong Ho

    1986-01-01

    This paper describes the design of the thermoluminescence analyser using microcomputer. TL analyser is designed to perform the three step heat treatment, such as pre-read heating, readout procedure and post-heating (or pre-irradiation ) anneal. We used a 12-bit A/D converter to get the precise measurement and the phase control method to control the heating temperature. Since the used Apple II microcomputer is cheap and popular, it is possible to design the economical system. Experimental results showed the successful operation with flexibility. The error of temperature control was less than ± 0.2% of the expected value. (Author)

  7. Progress in TL Dating at Risø

    DEFF Research Database (Denmark)

    Mejdahl, V.

    1972-01-01

    This article outlines the thermoluminescent dating technique employed at Risö. The intensity of beta and gamma radiation is determined by means of the TL phosphors CaSO4:Mn and CaSO4:Dy, and the determination of accumulated exposure is based on quartz and feldspar inclusions with a size of 0.......3–0.5 mm. Results are presented of a dating programme comprising sherds, bricks, burned stones and burned clay (from kilns) from seventeen excavation sites. The age of the sites ranged from a.d. 1600 to 4000 b.c....

  8. Environmental monitoring by CaSO4:Dy TL dosimeters

    International Nuclear Information System (INIS)

    Deme, S.; Szabo, P.P.

    1975-12-01

    The thermoluminescent dosimeters of high sensitivity are useful for monitoring the area near nuclear installations. CaSO 4 :Dy TL dosimeters have high sensitivity and low fading so that by means of them the dose from the background can be measured with an accuracy of 10-20%. An increase of 2 mR in the background can be observed and doses as high as 1000R can be registered with an accuracy of 5%. The measuring method and results are reported here. For two years these CaSO 4 :Dy dosimeters have been successfully used at the site of the Central Research Institute for Physics. (K.A.)

  9. MF-plan till företaget Design TL

    OpenAIRE

    Virtanen, Aino

    2015-01-01

    Examensarbetet gjordes för företaget Design TL med uppgiften att göra en mark-nadsföringsplan för företaget som skall starta verksamheten 2016. Detta examensar-bete har utförts genom litteraturstudie och information av uppdragsgivaren. Upp-dragsgivaren var Tarja Lamberg. Företaget sysslar med konst, konsthantverks plane-ring och design, tillverkning och försäljning. Uppdragsgivaren gav mig fria händer med planet, det enda som skulle tas i beakta var den begränsade budgeten. Teoride-len satte...

  10. Spins of superdeformed rotational bands in Tl isotopes

    Energy Technology Data Exchange (ETDEWEB)

    Dadwal, Anshul; Mittal, H.M. [Dr. B.R. Ambedkar National Institute of Technology, Jalandhar (India)

    2017-01-15

    The two-parameter model defined for even-even nuclei viz. soft-rotor formula is used to assign the band-head spin of the 17 rotational bands in Tl isotopes. The least-squares fitting method is employed to obtain the spins of these bands in the A ∝ 190 mass region. The calculated transition energies are found to depend sensitively on the proposed spin. Whenever a correct spin assignment is made, the calculated and experimental transition energies coincide very well. The dynamic moment of inertia is also calculated and its variation with rotational frequency is explored. (orig.)

  11. Double blocking in the superdeformed {sup 192}Tl nucleus

    Energy Technology Data Exchange (ETDEWEB)

    Liang, Y; Carpenter, M P; Janssens, R V.F.; Ahmad, I; Henry, R; Khoo, T L; Lauritsen, T [Argonne National Lab., IL (United States); Soramel, F [Padova University, Padova (Italy); Pilotte, S [Ottawa Univ., ON (Canada); Lewis, J M; Riedinger, L L; Yu, C H [Tennessee Univ., Knoxville, TN (United States); Garg, U; Reviol, W [Notre Dame Univ., IN (United States); Bearden, I G [Purdue Univ., Lafayette, IN (United States)

    1992-08-01

    Six superdeformed bands have been found in the nucleus {sup 192}Tl. For two of the bands, the dynamic moment of inertia J{sup (2)} is found to be constant with the rotational frequency {Dirac_h}{omega}. This result can be understood in terms of Pauli blocking of quasiparticle alignments in intruder orbitals, and represents the first experimental evidence that the alignment of these intruders is responsible for the smooth rise in J{sup (2)} seen in other superdeformed nuclei of this mass region. (author). 18 refs., 2 figs.

  12. Scintigraphic detection of ischemic and other myocardial lesions using 201Tl

    International Nuclear Information System (INIS)

    Duska, F.; Novak, J.; Vizda, J.; Kubicek, J.; Kafka, P.

    1981-01-01

    Current knowledge of the myocardium scintiscanning using 201 Tl is briefly outlined. The principle is shown of 201 Tl cumulation in a healthy myocardium and the use of the radionuclide is justified. Heart scintiscanning after exercise or after administration of drugs increasing the blood flow through the coronaries allows detecting latent ischaemic heart disease. 201 Tl scintigraphy can also be used for diagnosing the myocardial infarction, angina pectoris and other heart diseases. (J.P.)

  13. Electronic Structure of TlBa2CaCu2O(7-Delta)

    Science.gov (United States)

    Vasquez, R. P.; Novikov, D. L.; Freeman, A. J.; Siegal, M. P.

    1997-01-01

    The core levels of TlBa2CaCu2O(7-delta) (Tl-1212) epitaxial films have been measured with X-ray photoelectron spectroscopy (XPS). The valence electronic structure has been determined using the full-potential linear muffin-tin-orbital band-structure method and measured with XPS. The calculations show that a van Hove singularity (VHS) lies above the Fermi level (E(sub F)) for the stoichiometric compound (delta = 0.5), while for 50% oxygen vacancies in the Tl-O layer (delta = 0.5) E(sub F) is in close proximity to the VHS. Samples annealed in nitrogen (to reduce the hole overdoping by the removal of oxygen) exhibit higher core-level binding energies and a higher T(sub c), consistent with a shift of E(sub F) closer to the VHS. Comparisons are made to the core levels and valence bands of Tl2Ba2CaCu2O(8 + delta)(Tl-2212) and HgBa2CaCu2O)6 + delta) (Hg- 1212). The similarity of the Cu 2p(sub 3/2) spectra for Tl-1212 and Tl-2212 indicates that the number of Tl-O layers has little effect on the Cu-O bonding. However, the Tl-1212 and Hg-1212 Cu 2p(sub 3/2) signals exhibit differences which suggest that the replacement of T(sup 3+) with Hg(sup 2+) results in a decrease in the O 2p right arrow Cu 3d charge-transfer energy and differences in the probabilities of planar vs apical oxygen charge transfer and/or Zhang-Rice singlet-state formation. Differences between the Tl-1212 and the Tl-2212 and Hg-1212 measured valence bands are consistent with the calculated Cu 3d and (Tl,Hg) 6s/5d partial densities of states.

  14. Photo-TL in CaSO4:Dy: high exposure dosimetry

    International Nuclear Information System (INIS)

    Caldas, L.V.E.; Mayhugh, M.R.

    1974-01-01

    CaSO 4 :Dy exposed to 10 3 to 10 8 R then annealed in the range 280 to 400 0 C displays little TL in the major dosimetry peak near 200 0 C. Subsequent illumination with 250 nm light reinduces the 200 0 C TL. This radiation-enabled photo-TL is roughly proportional to the square root of the enabling exposure at least to 10 8 R. (auth)

  15. Microcomputer-Controlled Reader Systems for Archaeological and Geological TL Dating

    DEFF Research Database (Denmark)

    Bøtter-Jensen, Lars; Mejdahl, V.

    1984-01-01

    Two fully automated TL reader systems for TL dating and a manually operated reader for research purpose were put into operation during 1982-3. All systems are controlled by HP-85 or HP-86 microcomputers; thus flexibility in selection of measurement parameters, calculation of TL signals and displa...... the archaeological and geological ages. The principle of the measurement procedures are described, and dating results are presented to illustrate the performance of the systems...

  16. Amorphous-like interfacial layer between a high-Tc superconducting Tl-1223 film and a Ag substrate examined by high-voltage high-resolution transmission electron microscopy

    International Nuclear Information System (INIS)

    Kim, Bongjun; Kim, Hyuntak; Nagai, Takuro; Matsui, Yoshio; Horiuchi, Shigeo; Jeong, Daeyeong; Deinhofer, Christian; Gritzner, Gerhard; Kim, Youngmin; Kim, Younjoong

    2006-01-01

    The thin amorphous-like layer, formed at the interface between a high-T c superconducting (Tl 0.5 , Pb 0.5 )(Sr 0.8 , Ba 0.2 )Ca 2 Cu 3 O y (Tl-1223) film and a Ag substrate during heating at 910 .deg. C, has been examined by using high-voltage high-resolution transmission electron microscopy. The interfacial layer is less than 10 nm in thickness. It contacts the (001) plane of Tl-1223 and the (113) or (133) planes of Ag in most cases. Its composition is similar to that of Tl-1223, except for the inclusion of a substantial amount of Ag. Its formation proceeds by diffusion of Ag into Tl-1223, during which a structure change first occurs at the layer of CuO 2 + Ca planes. The Tl(Pb)O + the Sr(Ba)O layers are then destroyed to cause the total structure to become amorphous-like. Furthermore, we have found that it is formed under an irradiation of highly energetic electrons.

  17. Amorphous-like interfacial layer between a high-T{sub c} superconducting Tl-1223 film and a Ag substrate examined by high-voltage high-resolution transmission electron microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Bongjun; Kim, Hyuntak [Electronics and Tele-Communications Research Institute, Daejeon (Korea, Republic of); Nagai, Takuro; Matsui, Yoshio [National Institute for Materials Science, Tsukuba, Ibaraki (Japan); Horiuchi, Shigeo; Jeong, Daeyeong [Electrotechnology Research Institute, Changwon (Korea, Republic of); Deinhofer, Christian; Gritzner, Gerhard [Johannes Kepler University, Linz (Austria); Kim, Youngmin; Kim, Younjoong [Electron Microscopy Team, Korea Basic Science Institute, Daejeon (Korea, Republic of)

    2006-05-15

    The thin amorphous-like layer, formed at the interface between a high-T{sub c} superconducting (Tl{sub 0.5}, Pb{sub 0.5})(Sr{sub 0.8}, Ba{sub 0.2})Ca{sub 2}Cu{sub 3}O{sub y} (Tl-1223) film and a Ag substrate during heating at 910 .deg. C, has been examined by using high-voltage high-resolution transmission electron microscopy. The interfacial layer is less than 10 nm in thickness. It contacts the (001) plane of Tl-1223 and the (113) or (133) planes of Ag in most cases. Its composition is similar to that of Tl-1223, except for the inclusion of a substantial amount of Ag. Its formation proceeds by diffusion of Ag into Tl-1223, during which a structure change first occurs at the layer of CuO{sub 2} + Ca planes. The Tl(Pb)O + the Sr(Ba)O layers are then destroyed to cause the total structure to become amorphous-like. Furthermore, we have found that it is formed under an irradiation of highly energetic electrons.

  18. Telomere length analysis.

    Science.gov (United States)

    Canela, Andrés; Klatt, Peter; Blasco, María A

    2007-01-01

    Most somatic cells of long-lived species undergo telomere shortening throughout life. Critically short telomeres trigger loss of cell viability in tissues, which has been related to alteration of tissue function and loss of regenerative capabilities in aging and aging-related diseases. Hence, telomere length is an important biomarker for aging and can be used in the prognosis of aging diseases. These facts highlight the importance of developing methods for telomere length determination that can be employed to evaluate telomere length during the human aging process. Telomere length quantification methods have improved greatly in accuracy and sensitivity since the development of the conventional telomeric Southern blot. Here, we describe the different methodologies recently developed for telomere length quantification, as well as their potential applications for human aging studies.

  19. Activation energies from blue- and red-thermoluminescence (TL) of quartz grains and mean lives of trapped electrons related to natural red-TL

    International Nuclear Information System (INIS)

    Hashimoto, T.; Kojima, M.; Shirai, N.; Ichino, M.

    1993-01-01

    A three-dimensional representation of thermoluminescence (TL) spectra has been established by employing an image intensifier unit combined with a simple spectrophotometer and a microcomputer. By means of this TL spectrometric system, natural quartz grains could be distinguished as either blue-and/or red-TL ones. In these blue- and red-TL wavelength regions, activation energies from artificially irradiated quartz grains are evaluated using a repeated initial rise method. An apparent difference of activation energies in the two colorations was observed for dune sands presumably originating from different quartz sources. On the other hand, quartz grains extracted from a volcanic ash sediment showed completely similar activation energies in both TL color regions over all temperatures. Subsequently, the kinetic parameters were derived for the naturally occurring red-TL, possessing an apparent single peak around 340 o C, from volcanically originating quartz grains by fitting a theoretical equation to the glow curves, after evaluating activation energies. On the basis of the empirical kinetic parameters, the mean life of trapped electrons relating to a main 340 o C peak has been proved to be 1 million years, and a secondary weak peak around 280 o C in the natural red-TL glow curve has been confirmed. (author)

  20. Recovery of 201Tl by ion exchange chromatography from proton bombarded thallium cyclotron targets

    International Nuclear Information System (INIS)

    Walt, T.N. van der; Naidoo, C.

    2000-01-01

    A method based on ion exchange chromatography is presented for the recovery of 201 Tl and its precursor 201 Pb from proton bombarded natural thallium cyclotron targets. After bombardment the target is dissolved in diluted nitric acid. Water, hydrazine and ammonium acetate are added to the solution and the lead radioisotopes separated from the thallium by cation exchange chromatography on a Bio-Rex 70 column. The sorbed lead radioisotopes are eluted with dilute nitric acid and the separation repeated on a second Bio-Rex 70 column. After elution of the remaining thallium the column is left for 32 hours and the 201 Tl formed by decay of 201 Pb is eluted with an ammonium acetate solution. The 201 Tl eluate is acidified with a HNO 3 -HBr-Br 2 mixture and the resulting solution is passed through an AG MP-1 anion exchanger column to remove any remaining lead isotopes. The 201 Tl is eluted with a hydrazine solution, the eluate evaporated to dryness and the 201 Tl finally dissolved in an appropriate solution to produce a 201 TlCl solution suitable for medical use. A high quality 201 Tl product is obtained containing ≤ 0.1 μg of Tl/mCi (37 MBq) 201 Tl. The radionuclidic impurities are less than the maximum values specified by the US Pharmacopoeia and the British Pharmacopoeia. (orig.)

  1. Measurements of environmental gamma-ray spectra using a multi-element TL dosemeter

    International Nuclear Information System (INIS)

    Furuta, Sadaaki; Boetter-Jensen, L.; Nielsen, S.P.

    1986-12-01

    A method to estimate the energy distribution and dose of environmental gamma radiation was developed using a multielement TL dosemeter. Experimentally obtained energy responses from a multi-element TL dosemeter with different kinds of filters were used to calculate the energy distribution and related dose by the SAND-II computer code. The code was originally developed to estimate the neutron flux using a multiple foil activation method. Measurements were made at several locations with the multi-element TL dosemeter and comparisons were made with results from a NaI(Tl) scintillation detector and a high-pressure ionization chamber. (author)

  2. How Experienced SoTL Researchers Develop the Credibility of Their Work

    Directory of Open Access Journals (Sweden)

    Jennie Billot

    2017-03-01

    Full Text Available Teaching and learning research in higher education, often referred to as the Scholarship of Teaching and Learning (SoTL, is still relatively novel in many academic contexts compared to the mainstay of disciplinary research. One indication of this is the challenges those who engage in SoTL report in terms of how this work is valued or considered credible amongst disciplinary colleagues and in the face of institutional policies and practices. This paper moves beyond the literature that describes these specific challenges to investigate how 23 experienced SoTL researchers from five different countries understood the notion of credibility in relationship to their SoTL research and how they went about developing credibility for their work. Semi-structured interviews were facilitated and analyzed using inductive analysis. Findings indicate that notions of credibility encompassed putting SoTL research into action and building capacity and community around research findings, as well as gaining external validation through traditional indicators such as publishing. SoTL researchers reported a variety of strategies and approaches they were using, both formal and informal, to develop credibility for their work. The direct focus of this paper on credibility of SoTL work as perceived by experienced SoTL researchers, and how they go about developing credibility, is a distinct contribution to the discussions about the valuing of SoTL work.

  3. Self-trapping nature of Tl nanoclusters on the Si(111)-7x7 surface

    International Nuclear Information System (INIS)

    Hwang, C G; Kim, N D; Lee, G; Shin, S Y; Kim, J S; Chung, J W

    2008-01-01

    We have studied properties of thallium (Tl) nanoclusters formed on the Si(111)-7x7 surface at room temperature (RT) by utilizing photoemission spectroscopy (PES) and high-resolution electron-energy-loss spectroscopy (HREELS) combined with first principles calculations. Our PES data reveal that the surface states stemming from the Si substrate remain quite inert with Tl adsorption producing no Tl-induced state until saturation at Tl coverage θ=0.21 monolayers. Such a behavior, in sharp contrast with the extremely reactive surface states upon the formation of Na or Li nanoclusters, together with the presence of a unique Tl-induced loss peak in HREELS spectra suggests no strong Si-Tl bonding, and is well understood in terms of gradual filling of Si dangling bonds with increasing θ. Our calculation further indicates the presence of several metastable atomic structures of Tl nanoclusters at RT rapidly transforming from one to another faster than 10 10 flippings per second. We thus conclude that the highly mobile Tl atoms form self-trapped nanoclusters within the attractive basins of the Si substrate at RT with several metastable phases. The mobile and multi-phased nature of Tl nanoclusters not only accounts for all the existing experimental observations available at present, but also provides an example of self-trapping of atoms in a nanometre-scale region

  4. Auto-regenerative TL dating with zircon inclusions from fired materials

    International Nuclear Information System (INIS)

    Templer, R.H.; Smith, B.W.

    1988-01-01

    In this paper it is shown that it is possible to date fired material using zircon inclusions. The effects of zoning and anomalous fading are overcome using an auto-regenerative dating procedure. The high radioactivity of the grains gives a measurable self-induced TL (thermoluminescence) signal within a few months. Comparison of this ''auto-regenerated'' TL with the natural TL (which has accumulated since the firing) yields the age of the material. A sensitive TL reader capable of recording the auto-regenerated signal after 6 months is also described, and the results of age determinations on a number of known age samples are presented. (author)

  5. Two cases of hyperparathyroidism revealed by /sup 201/Tl-chloride

    Energy Technology Data Exchange (ETDEWEB)

    Otsuka, Kokichi; Asano, Haruko; Moriyama, Shigeharu (Okayama Red Cross Hospital (Japan))

    1983-08-01

    /sup 201/Tl scintigraphy at 15 min and 120 min after intravenous injection of /sup 201/TlCl revealed a parathyroidal adenoma (1.7g) in a 49-year-old female patient with hyperthyroidism complicated by renal calculi and that (1.8g) in a 58-year-old female patient without symptoms. /sup 75/Se could be substituted by /sup 201/Tl which was useful for localizing parathyroidal adenoma in hyperparathyroidism. /sup 201/Tl scintigraphy revealed the adenoma which was not palpable. The smallest adenoma detected by it was 0.9g.

  6. Risky family processes prospectively forecast shorter telomere length mediated through negative emotions.

    Science.gov (United States)

    Brody, Gene H; Yu, Tianyi; Shalev, Idan

    2017-05-01

    This study was designed to examine prospective associations of risky family environments with subsequent levels of negative emotions and peripheral blood mononuclear cell telomere length (TL), a marker of cellular aging. A second purpose was to determine whether negative emotions mediate the hypothesized link between risky family processes and diminished telomere length. Participants were 293 adolescents (age 17 years at the first assessment) and their primary caregivers. Caregivers provided data on risky family processes when the youths were age 17 years, youths reported their negative emotions at age 18 years, and youths' TL was assayed from a blood sample at age 22 years. The results revealed that (a) risky family processes forecast heightened negative emotions (β = .316, p emotions forecast shorter TL (β = -.187, p = .012), and (c) negative emotions served as a mediator connecting risky family processes with diminished TL (indirect effect = -0.012, 95% CI [-0.036, -0.002]). These findings are consistent with the hypothesis that risky family processes presage premature cellular aging through effects on negative emotions, with potential implications for lifelong health. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  7. Reverse 201Tl myocardial redistribution induced by coronary artery spasm

    International Nuclear Information System (INIS)

    Xiang Dingcheng; Yin Jilin; Gong Zhihua; Xie Zhenhong; Zhang Jinhe; Wen Yanfei; Yi Shaodong

    2010-01-01

    Objective: To investigate the mechanism of reverse redistribution (RR) on dipyridamole 201 Tl myocardial perfusion studies in the patients with coronary artery spasm. Methods: Twenty-six patients with coronary artery spasm and presented as RR on dipyridamole 201 Tl myocardial perfusion studies were enlisted as RR group, while other 16 patients with no coronary artery stenosis nor RR were enlisted as control group. Dipyridamole test was repeated during coronary angiography. Corrected thrombolysis in myocardial infarction (TIMI) frame count (CTFC) and TIMI myocardial perfusion grade (TMPG) were measured at RR related and non-RR related coronary arteries before and after dipyridamole infusion respectively. All of the data were analyzed by Student's t-test or χ 2 -test and correlation analysis. Results: Coronary artery angiography showed slower blood flow and lower myocardial perfusion in RR related vessels when compared with non-RR related vessels in RR group, but there was no significant difference among the main coronary arteries in control group. The perfusion defects of RR area at rest were positively related to slower blood velocity at corresponding coronary arteries (r = 0.79, t =10.18, P 0.05). Conclusion: RR is related to the decreased blood flow and myocardial perfusion induced by coronary artery spasm at rest, which may be improved by stress test such as intravenous dipyridamole infusion. (authors)

  8. Radiation accident dosimetry: TL properties of mobile phone screen glass

    International Nuclear Information System (INIS)

    Bassinet, C.; Pirault, N.; Baumann, M.; Clairand, I.

    2014-01-01

    Mobile phones are carried by a large part of the population and previous studies have shown that they may be able to function as individual fortuitous dosimeters in case of radiological accident. This study deals with thermoluminescence (TL) properties of mobile phone screen glass. The presence of a significant background signal which partially overlaps with the radiation-induced signal is a serious issue for dose reconstruction. A mechanical method to reduce this signal using a diamond grinding bit is presented. An over-response at low energy (∼50 keV) is observed for two investigated glasses. The results of a dose recovery test using a single-aliquot regenerative-dose (SAR) procedure are discussed. - Highlights: • Mobile phone screen glass is a promising material for retrospective dosimetry. • The TL non-radiation induced background signal can be significantly reduced by a mechanical method. • A dose recovery test using an SAR procedure was successfully carried out for the investigated glass

  9. Developing SoTL through Organized Scholarship Institutes

    Directory of Open Access Journals (Sweden)

    Elizabeth Marquis

    2015-12-01

    Full Text Available The need to further integrate SoTL into college and university cultures has been discussed relatively frequently in recent teaching and learning literature. While a number of useful strategies to assist in this task have been advanced, one especially promising suggestion is the development of organized, institutionally-recognized scholarship institutes. Centres or units of this sort have been created at higher education institutions in a number of countries, but little published information currently exists about the design of these institutes or the experiences of individuals affiliated with them. To that end, the present study sought to examine the perceived benefits, challenges and design features of teaching and learning scholarship institutes at research-intensive universities worldwide. A website scan and a survey of individuals affiliated with these units were used to collect qualitative and quantitative data of relevance to the research questions. Based on the findings, and on ideas from the existing research institute and scholarship of teaching and learning literatures, a series of recommendations for individuals and campuses interested in developing effective SoTL institutes are provided.

  10. Total protein

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/article/003483.htm Total protein To use the sharing features on this page, please enable JavaScript. The total protein test measures the total amount of two classes ...

  11. Influence of adding BaSnO3 nanoparticles on magnetic transport properties for CuTl-1223 phase

    Directory of Open Access Journals (Sweden)

    M.ME. Barakat

    Full Text Available Co-precipitation method and solid-state reaction technique were used to synthesize BaSnO3 nanoparticles and (BaSnO3x/Cu0.5Tl0.5Ba2Ca2Cu3O10−δ samples, 0.00 ≤ x ≤ 1.50 wt%, respectively. All samples were characterized using X-ray powder diffraction (XRD and electrical resistivity measurements at different applied DC magnetic fields ranged from 0.29 to 4.40 kG. The relative volume fraction, superconducting transition temperature, Tc, and hole carriers concentration, P, were enhanced by increasing x up to 0.25 wt%, beyond which they were decreased for further increase in the addition of BaSnO3 nanoparticles. Both thermally activated flux creep (TAFC model and Ambegaokar and Halperin (AH theory were used to analyze the magnetoresistance data for (BaSnO3x/CuTl-1223 samples. An enhancement in the derived magnetic superconducting parameters, including the flux pinning energy, U, critical current density, Jc(0, and upper critical magnetic field, Bc2(0, as well as a decrement in the coherence length at 0 K, ξ(0, was achieved by adding BaSnO3 nanoparticles up to 0.25 wt%. A reverse trend was recorded for further addition of BaSnO3 nanoparticles. The electronic thermal conductivity, κe, was decreased by increasing applied magnetic fields below Tc. Keywords: CuTl-1223 phase, BaSnO3 nanoparticles, Flux pinning energy, Critical current density

  12. Individual stem value recovery of modified and conventional tree-length systems in the southeastern United States

    Science.gov (United States)

    Amanda H. Lang; Shawn A. Baker; W. Dale Greene; Glen E. Murphy

    2010-01-01

    We compared value recovery of a modified treelength (MTL) logging system that measures product diameter and length using a Waratah 626 harvester head to that of a treelength (TL) system that estimates dimensions. A field test compared the actual value cut to the maximum potential value suggested by the log bucking optimization program Assessment of Value by Individual...

  13. Quantitative assessment of myocardial blood flow by measurement of fractional myocardial uptake of 201Tl

    International Nuclear Information System (INIS)

    Yonekura, Yoshiharu; Ishii, Yasushi; Torizuka, Kanji; Kadota, Kazunori; Kambara, Hirofumi

    1980-01-01

    Fractional Myocardial uptake of 201 Tl was measured for the quantitative assessment of myocardial blood flow in coronary artery disease (CAD). 10 normals and 28 CAD, 7 of which have less than 50% stenosis (CAD I) and 21 of which have more than 50% stenosis (CAD II) in the proximal portion of coronary arteries, were studied at rest and with submaximal exercise loading by bicycle ergometer. After intravenous injection of 201 Tl, its rapid transport process was recorded during the initial 5 minutes by a scintillation camera and a minicomputer. Total injected dosage (T) was obtained from the counts of the entire chest region during the initial passage of the tracer through the heart and lung. Myocardial uptake (M) was counted with the same geometry from the subsequent accumulation within the myocardial region with subtraction of the background activities in the upper mediastinal region (B). The fractional myocardial uptake of 201 Tl ((M-B)/T) is assumed to be proportional to the fractional myocardial blood flow to cardiac output (MBF/CO) according to the indicator fractionation principle. The average value of MBF/CO at rest in CAD (4.11 +- 1.12%) was significantly greater than in normals (3.36 +- 0.49%), which may be caused by an increased left ventricular mass in CAD. Change rate of MBF/CO on the exercise loading was significantly less in CAD I (1.36 +- 0.14) and in CAD II (1.11 +- 0.21) than in normals (1.75 +- 0.11). MBF/CO increased proportionally to the increment of the double product of heart rate and systolic blood pressure by exercise loading in normals, whereas it didn't in CAD. The sensitivity of this method was superior to the stress electrocardiogram and the stress myocardial perfusion imaging, not only in CAD II but also in CAD I. This result indicated that this type of global assessment of the myocardial reserve capacity is valuable in addition to the simple stress myocardial perfusion imaging. (author)

  14. Phase diagrams of novel Tl{sub 4}SnSe{sub 4}–TlSbSe{sub 2}–Tl{sub 2}SnSe{sub 3} quasi-ternary system following DTA and X-ray diffraction

    Energy Technology Data Exchange (ETDEWEB)

    Barchiy, I.E.; Tatzkar, A.R. [Department of Chemistry, Uzhgorod National University, Pidgirna St., 46, Uzhgorod 88000 (Ukraine); Fedorchuk, A.O. [Department of Inorganic and Organic Chemistry, Lviv National University of Veterinary Medicine and Biotechnologies, Pekarska St., 50, Lviv 79010 (Ukraine); Plucinski, K., E-mail: kpluc2006@wp.pl [Electronics Department, Military University Technology, Warsaw, Kaliskiego 2, Warsaw 00-908 (Poland)

    2016-06-25

    Phase relation in the Tl{sub 4}SnSe{sub 4}–TlSbSe{sub 2}–Tl{sub 2}SnSe{sub 3} quasiternary system were studied by the DTA and X-ray diffraction in combination with mathematical modeling. The phase diagrams of the Tl{sub 4}SnSe{sub 4}–TlSbSe{sub 2} and Tl{sub 2}SnSe{sub 3}–TlSbSe{sub 2} systems, the perspective views of the phase interaction in the ternary system, the liquidus surface projection, the isothermal section at 423 K were built for the first time. The Tl{sub 4}SnSe{sub 4}–TlSbSe{sub 2}–Tl{sub 2}SnSe{sub 3} system is of the invariant eutectic type and is characterized by the formation of limited solid solutions following initial ternary compounds. New complex compounds are not formed. - Highlights: • Two Tl{sub 4}SnSe{sub 4}–TlSbSe{sub 2},Tl{sub 2}SnSe{sub 3}–TlSbSe{sub 2} systems were explored. • Invariant processes in the ternary system were determined. • New complex compounds were not observed in ternary system.

  15. Telomere length and depression

    DEFF Research Database (Denmark)

    Wium-Andersen, Marie Kim; Ørsted, David Dynnes; Rode, Line

    2017-01-01

    BACKGROUND: Depression has been cross-sectionally associated with short telomeres as a measure of biological age. However, the direction and nature of the association is currently unclear. AIMS: We examined whether short telomere length is associated with depression cross-sectionally as well...... as prospectively and genetically. METHOD: Telomere length and three polymorphisms, TERT, TERC and OBFC1, were measured in 67 306 individuals aged 20-100 years from the Danish general population and associated with register-based attendance at hospital for depression and purchase of antidepressant medication....... RESULTS: Attendance at hospital for depression was associated with short telomere length cross-sectionally, but not prospectively. Further, purchase of antidepressant medication was not associated with short telomere length cross-sectionally or prospectively. Mean follow-up was 7.6 years (range 0...

  16. Tl response of KMgF{sub 3}: Lu + PTFE at ultraviolet radiation; Respuesta Tl de KMgF{sub 3}: Lu + PTFE a radiacion ultravioleta

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez, P R [Instituto Nacional de Investigaciones Nucleares, A.P. 18 -1027, 11801 Mexico D.F. (Mexico); Alarcon, N G [Facultad de Quimica, Universidad Autonoma del Estado de Mexico. Paseo Tollocan, Esq. con Jesus Carranza, 50180 Toluca, Estado de Mexico (Mexico); Furetta, C; Azorin, J [Universidad Autonoma Metropolitana- Iztapalapa, San Rafael Atlixco 186, 09340 Mexico. D.F. (Mexico)

    2003-07-01

    Ionizing radiation has different types of interaction with a crystalline solid. However, only few effects are interesting to optimize some thermoluminescent (Tl) properties of certain Tl materials. This paper presents results obtained by irradiating KMgF{sub 3}: Lu + Ptfe Tl dosimeters with ultraviolet (UV) radiation previously exposed to gamma radiation. These results showed that those dosimeters not exposed previously to gamma radiation did not presented any Tl signal. Meanwhile, those previously submitted to gamma irradiation showed that their sensitivity was increased as the gamma dose increased. The glow curve of sensitized KMgF{sub 3}: Lu + Ptfe exposed to UV radiation, presented the dosimetric pea at 212 C. This makes this material to be promissory for measuring UV radiation. (Author)

  17. Myocardial scintigraphy with /sup 201/Tl and quantitative assessment of myocardial blood flow

    Energy Technology Data Exchange (ETDEWEB)

    Ishii, Y; Kanbara, H; Yonekura, Y; Kadota, K; Fujita, T [Kyoto Univ. (Japan). Faculty of Medicine

    1976-12-01

    A newly introduced radionuclide for myocardial imaging, /sup 201/Tl, was studied. Twenty-two subjects consisting of 7 normals, 12 with ischemic heart disease and 3 with hypertrophic cardiomyopathy (HCM) were selected. On intravenous administration of /sup 201/Tl(1.5 to 20. mCi), initial transit of the tracer through the heart, as well as subsequent uptake by the myocardium, were recorded by a scintillation camera. The later process showed the distribution of the myocardial blood flow (MBF). A normal myocardial scintigraphy revealed the left-sided myocardial mass predominantly, whereas the right side or the septum predominated in the case of tetralogy of fallot (T/F) or idiopathic hypertrophic subuaortic stenosis (IHSS). An ischemic or infarcted area of the myocardium in ischemic heart disease (IHD) was compatible with electrocardiographic findings, and revealed defects even in an equivocal case on ECG. Since the ratio of radioactivity taken up by the myocardium (U) to the total injected dosis (I) is assumed to be proportional to the fractional MBF of cardiac output (CO), MBF/CO is calculated by ratio of the radioactivity selected from myocardial region on the later recording to that from the entire region on the initial transit of the tracer bolus. The average MBF/CO of normals was 4.4 +- 0.5%, IHD 4.0 +- 0.8% and HCM 5.5 +- 1.2%. On exercise loading, a significant increase of this value was observed in normals, whereas no change was observed in IHD.

  18. Emission computed tomography using rotating gamma cameras for stress 201Tl myocardial imaging

    International Nuclear Information System (INIS)

    Takeda, Kan; Maeda, Hisato; Nakagawa, Tsuyoshi; Yamaguchi, Nobuo; Taguchi, Mitsuo

    1983-01-01

    The purpose of this study is to evaluate the efficacy of emission computed tomography (ECT) for stress 201 Tl myocardial imaging to localize coronary artery disease (CAD) in comparison with planar (PL) images. In a series of 14 normal subjects and 53 patients with CAD proved coronary arteriography, ECT and PL imaging were performed successively. ECT data were collected for 90 projections in a 64 x 64 matrix form with a total aquisition time of 6 munutes over 180 0 of opposed dual cameras ratation and tomographic sections oriented perpendicular and parallel to the long axis of left ventricle were reconstructed. PL images were obtained for left lateral, left anterior oblique (30 0 and 45 0 ) and anterior projections. Both ECT and PL myocardial images were divided into 8 segments and segmental analysis was performed by visual interpretation. The ECT images remarkably increased sensitivity over the PL images in left anterior descending (LAD) artery (from 56% to 76%), right coronary artery (RCA) (from 50% to 96%), and circumflex artery (CX) (from 56% to 69%) lesions. The specificity for ECT images, as compared with PL images, was higher in LAD (88% against 85%) but slightly lower in RCA (70% ag ainst 72%) and CX (84% against 88%). Overall accuracy, therefore, was improved in LAD (from 67% to 81%) and RCA (from 64% to 79%) but equal in CX (81%). We conclude that stress 201 Tl ECT imaging result in a remarkable improvement in the localization of CAD, especially in patients with RCA lesions and multi-vessel disease. (author)

  19. Investigation of the gamma radiation from the inelastic scattering of 2.75 MeV on 203Tl and 205Tl

    International Nuclear Information System (INIS)

    Hegewisch, S.

    1976-01-01

    The experimental presupositions for the measurements of (n,n'γ) reactions with time of flight discrimination have been established. By an investigation of the isotopes 203 Tl and 205 Tl with this method 120 gamma-transitions could be determined. The exact evaluation of their energies and intensities led to a completion of the level diagrams. The enrgies could be determined with a precision nearly one order of magnitude higher than the values existing hither to. (orig./WL) [de

  20. The superconductor (Tl,Hg,Ca)2(Ba,Sr)2(Ca,Sr,Tl)Cu2O7.6

    International Nuclear Information System (INIS)

    Valldor, M.; Bryntse, I.; Morawski, A.

    2002-01-01

    In the title 2212-type superconductor (thallium mercury calcium barium strontium copper oxide), which contains both Tl and Hg in the charge reservoir (CR), Sr is located at both alkali-earth (AE) metal sites. Ca enters the CR at the same time as Tl shares the smaller AE site, which increases the apical Cu-Cu distance significantly. The structure causes the superconducting Cu-O layers to become significantly puckered. (orig.)

  1. Antiferromagnetism Induced in the Vortex Core of Tl2Ba2CuO6++δ Probed by Spatially-Resolved 205Tl-NMR

    International Nuclear Information System (INIS)

    Kumagai, K.; Kakuyanagi, K.; Matsuda, Y.; Hasegawa, T.

    2003-01-01

    Magnetism in the vortex core state has been studied by spatially-resolved NMR. The nuclear spin lattice relaxation rate T 1 -1 of 205 Tl in nearly optimal-doped Tl 2 Ba 2 CuO 6+ δ (T c =85 K) is significantly enhanced in the vortex core region. The NMR results suggest that the suppression of the d-wave superconducting order parameter in the vortex core leads to the nucleation of islands with local antiferromagnetic (AF) order. (author)

  2. Study of multi-quasiparticle band structures in 197Tl using α beam

    International Nuclear Information System (INIS)

    Mukherjee, G.; Nandi, S.; Pai, H.

    2016-01-01

    Study of the multi-quasiparticle (qp) states and the band structures built on them in the neutron deficient Tl nuclei in A ∼ 190 mass region provides useful information on particle-hole interaction in the heavy nuclei. In order to investigate the multi-qp band structures we have studied the excited states in 197 Tl by gamma ray spectroscopy

  3. On the Constitution of SoTL: Its Domains and Contexts

    Science.gov (United States)

    Booth, S.; Woollacott, L. C.

    2018-01-01

    In this paper, we present an analysis of the Scholarship of Teaching and Learning in Higher Education (SoTL) which contributes to SoTL both as a field of research practice and as a background to professional development in higher education. We analyse and describe the constitution of the field, and in so doing address its nature in the face of the…

  4. Enhanced thermoelectric figure of merit in strained Tl-doped Bi2Se3

    KAUST Repository

    Saeed, Y.; Singh, Nirpendra; Schwingenschlö gl, Udo

    2014-01-01

    We explain recent experimental findings on Tl-doped Bi2Se3 by determining the electronic and transport properties by first-principles calculations and semi-classical Boltzmann theory. Though Tl-doping introduces a momentum-dependent spin

  5. Identification of food preserved by ionizing radiation; Preliminary tests in strawberries using thermoluminescent (TL)

    International Nuclear Information System (INIS)

    Rubio, T.; Sillano, O.; Espinoza, J.; Roman, A.; Deza, A.

    1992-01-01

    TL measurements, of irradiated and unirradiated strawberries were carried out, using peel, seeds (achenes), leaves and sediment. The four types of samples presented a different thermoluminescence response. The best results were obtained with sediment removed from the soil of the fruit surface. It is concluded that TL is a promising technique for detecting irradiated strawberries using sediment samples. (author)

  6. Value of dipyridamole stress 201Tl myocardial SPECT in detecting dysfunction of coronary microcirculation

    International Nuclear Information System (INIS)

    Lou Ying; Jiang Jinqi; Xie Wenhui; Yuan Fang; Wang Tong; Yang Yiqing

    2012-01-01

    Objective: To evaluate the value of dipyridamole stress 201 Tl myocardial SPECT in detecting dysfunction of coronary microcirculation. Methods: Forty-eight patients diagnosed with cardiac syndrome X underwent dipyridamole stress 201 Tl myocardial SPECT. Dipyridamole (0.56 mg/kg) was intravenously injected over 4 min followed by 201 Tl (111 MBq) injection at 2 min after dipyridamole administration. Image was acquired at 10 min and 240 min post-injection and co-analyzed by over two experienced doctors in nuclear medicine after three-dimensional reconstruction. The patients with 'reverse redistribution' underwent repeated dipyridamole stress 201 Tl SPECT after medical therapy for 2 weeks. The clinical symptoms and results of the treadmill exercise test pre-and post-therapy were compared. Results: Forty two patients (42/48, 87.50%) showed segmental defects: 'reverse redistribution' on delayed (240 min) 201 Tl images. After medical treatment, 36 cases of the 42 'reverse redistribution' patients had improvement in both clinical symptoms and treadmill exercise test. Post-treatment 201 Tl imaging showed improvement in 45/49 (91.84%) defect segments. Six of the 42 patients had no improvement in clinical symptoms and/or treadmill exercise test. Post-treatment 201 Tl imaging showed no improvement in all the 7 defect segments on the first scan. Conclusion: Dipyridamole stress 201 Tl myocardial SPECT may be valuable in evaluation of impaired coronary microcirculation associated with cardiac syndrome X. (authors)

  7. Observation of curious spiral growth features in Tl doped Hg bearing ...

    Indian Academy of Sciences (India)

    Synthesis of H(Tl)Ba2Ca2Cu3O8+ superconducting tapes have been accomplished by annealing the precursor tape, Ba2Ca2Cu3O (fabricated by doctor blade tape casting technique) in an environment of H(Tl) vapour. Characterization of superconducting HTSC tape sample was carried out through XRD, TEM, SEM ...

  8. Pulse shaping for fast coincidence with NaI(Tl) detectors

    International Nuclear Information System (INIS)

    Bose, S.; Sinha, B.K.; Bhattacharya, R.

    1983-01-01

    The effect of multiple limiting of the anode pulses of the photomultiplier tubes on the resolving time of an NaI(Tl)-NaI(Tl) fast coincidence set up is investigated with the help of a simple transistored limiter circuit. The performance of the set up for different energy ranges selected in the side channels is also investigated. (orig.)

  9. TL and ESR based identification of gamma-irradiated frozen fish using different hydrolysis techniques

    International Nuclear Information System (INIS)

    Ahn, Jae-Jun; Akram, Kashif; Shahbaz, Hafiz Muhammad; Kwon, Joong-Ho

    2014-01-01

    Frozen fish fillets (walleye Pollack and Japanese Spanish mackerel) were selected as samples for irradiation (0–10 kGy) detection trials using different hydrolysis methods. Photostimulated luminescence (PSL)-based screening analysis for gamma-irradiated frozen fillets showed low sensitivity due to limited silicate mineral contents on the samples. Same limitations were found in the thermoluminescence (TL) analysis on mineral samples isolated by density separation method. However, acid (HCl) and alkali (KOH) hydrolysis methods were effective in getting enough minerals to carry out TL analysis, which was reconfirmed through the normalization step by calculating the TL ratios (TL 1 /TL 2 ). For improved electron spin resonance (ESR) analysis, alkali and enzyme (alcalase) hydrolysis methods were compared in separating minute-bone fractions. The enzymatic method provided more clear radiation-specific hydroxyapatite radicals than that of the alkaline method. Different hydrolysis methods could extend the application of TL and ESR techniques in identifying the irradiation history of frozen fish fillets. - Highlights: • Irradiation has potential to improve hygienic quality of raw and processed seafood. • Detection of irradiated food is important to enforce the applied regulations. • Different techniques were compared to separate silicate minerals from frozen fish. • Limitations were observed in TL analysis on minerals isolated by density separation. • Hydrolysis methods provided more clear identification using TL and ESR techniques

  10. Studies on the tumor and organ affinity of /sup 201/Tl

    Energy Technology Data Exchange (ETDEWEB)

    Mori, H; Ando, I; Takeuchi, T [Kanazawa Univ. (Japan). School of Medicine; Ando, A; Hiraki, T

    1980-01-01

    In order to evaluate the tumor and organ affinity of /sup 201/Tl, using the Yoshida sarcoma bearing rats, the distribution of /sup 201/Tl/sup +/ in tissues and tumor was examined and compared to /sup 22/Na/sup +/, /sup 42/K/sup +/, /sup 86/Rb/sup +/, /sup 134/Cs/sup +/, and /sup 67/Ga-citrate. /sup 201/Tl/sup +/ showed almost same organ accumulation and kinetics as /sup 42/K/sup +/, /sup 86/Rb/sup +/, /sup 134/Cs, whereas /sup 201/Tl/sup +/ and /sup 22/Na/sup +/ had completely different organ distribution. These results suggest that organ affinity of /sup 201/Tl/sup +/ might be related to active transport, namely Na/sup +/-K/sup +/-ATPase pump mechanism as well as blood flow. However, it appeared to be taken into account the other factors such as different accumulation and clearance rate due to different substrates of organs. Kidney accumulation rate of /sup 201/Tl/sup +/ was much higher than /sup 42/K/sup +/, /sup 86/Rb/sup +/, /sup 134/Cs/sup +/ and about 10 times as /sup 42/K/sup +/. Macroautoradiograms of rat kidneys showed that /sup 201/Tl/sup +/ exhibited an initial high accumulation in the cortex and appeared in the outer cortex, as the cortex cleared of radioactivity. /sup 201/Tl might be interchangeable with K/sup +/ in the tubular system, reabsorbed with more affinity and cleared more slowly than K/sup +/. The tumor accumulation /sup 201/Tl/sup +/ might be related to Na/sup +/-K/sup +/-ATPase pump mechanism as well as other organs. However, in terms of tumor accumulation and concentration ratio to other organs, /sup 201/Tl/sup +/ was inferior to /sup 67/Ga-citrate, although the tumor to blood ratio was identical to that of /sup 67/Ga-citrate. Since /sup 201/Tl/sup + + +/ showed almost same distribution as /sup 201/Tl/sup +/, /sup 201/Tl/sup + + +/ might change into /sup 201/Tl/sup +/ in vivo.

  11. Totally optimal decision rules

    KAUST Repository

    Amin, Talha

    2017-11-22

    Optimality of decision rules (patterns) can be measured in many ways. One of these is referred to as length. Length signifies the number of terms in a decision rule and is optimally minimized. Another, coverage represents the width of a rule’s applicability and generality. As such, it is desirable to maximize coverage. A totally optimal decision rule is a decision rule that has the minimum possible length and the maximum possible coverage. This paper presents a method for determining the presence of totally optimal decision rules for “complete” decision tables (representations of total functions in which different variables can have domains of differing values). Depending on the cardinalities of the domains, we can either guarantee for each tuple of values of the function that totally optimal rules exist for each row of the table (as in the case of total Boolean functions where the cardinalities are equal to 2) or, for each row, we can find a tuple of values of the function for which totally optimal rules do not exist for this row.

  12. Totally optimal decision rules

    KAUST Repository

    Amin, Talha M.; Moshkov, Mikhail

    2017-01-01

    Optimality of decision rules (patterns) can be measured in many ways. One of these is referred to as length. Length signifies the number of terms in a decision rule and is optimally minimized. Another, coverage represents the width of a rule’s applicability and generality. As such, it is desirable to maximize coverage. A totally optimal decision rule is a decision rule that has the minimum possible length and the maximum possible coverage. This paper presents a method for determining the presence of totally optimal decision rules for “complete” decision tables (representations of total functions in which different variables can have domains of differing values). Depending on the cardinalities of the domains, we can either guarantee for each tuple of values of the function that totally optimal rules exist for each row of the table (as in the case of total Boolean functions where the cardinalities are equal to 2) or, for each row, we can find a tuple of values of the function for which totally optimal rules do not exist for this row.

  13. Synthesis and properties of Tl endash Ba endash Ca endash Cu endash O superconductors

    International Nuclear Information System (INIS)

    Siegal, M.P.; Venturini, E.L.; Morosin, B.; Aselage, T.L.

    1997-01-01

    We review the synthesis methods and properties of single crystal, powder and thin film TlBaCaCuO high-temperature superconducting (Tl-HTS) materials. With transition temperatures ≥100K for several compounds, Tl-HTS materials present real opportunities for applications above 77 K. Experiments using (1) single crystals: determined precise structural parameters and identified the complex Tl 1+ -Tl 3+ equilibrium model; (2) powders: studied the complex thermodynamic phase diagram; and (3) epitaxial films: have studied fundamental properties such as electron pair symmetry and the effect of controlled extrinsic defects on flux pinning strength, as well as providing the large-area surfaces required for device applications. copyright 1997 Materials Research Society

  14. Effects of smoking on lung uptake of 201Tl during exercise myocardial perfusion imaging

    International Nuclear Information System (INIS)

    Ouyang Wei; He Guorong; Liu Jinhua

    2004-01-01

    Objective: To investigate the influence of smoking on lung uptake of 201 Tl during myocardial perfusion imaging. Methods: Ninety-two healthy subjects, with normal 201 Tl myocardial perfusion imaging findings but no evidence of left ventricular hypertrophy and pulmonary disease, were divided into three groups, smoker, nonsmoker and quitted smoker groups. Exercise/delay 201 Tl myocardial perfusion imaging was performed on all subjects included. Lung/heart ratio was defined on the anterior planar image obtained during exercise tomography. Results: Both the lung/heart ratios during exercise in smoker (0.40 ± 0.07, F=10.635, P 201 Tl lung/heart ratios in smokers are higher than in nonsmokers and this must be kept in mind when 201 Tl lung/heart ratios are used clinically, even in quitted smokers

  15. A Call for Expanding Inclusive Student Engagement in SoTL

    Directory of Open Access Journals (Sweden)

    Peter Felten

    2013-09-01

    of student-faculty partnerships focused on inquiry into teaching and learning. However, some students tend to be privileged in SoTL initiatives while others are discouraged, implicitly or explicitly, from engaging in this work. In this paper, we consider why certain students tend to be excluded from SoTL, summarize the possible developmental gains made by students and faculty when diverse student voices are included, and highlight strategies for generating a more inclusive SoTL. We call for expanding student engagement in SoTL by encouraging a diversity of student voices to engage in co-inquiry with faculty. Inclusive engagement has tremendous potential to enhance student and faculty learning, to deepen SoTL initiatives, and to help redress the exclusionary practices that too often occur in higher education.

  16. Sample dependent correlation between TL and LM-OSL in Al2O3:C

    International Nuclear Information System (INIS)

    Dallas, G.I.; Polymeris, G.S.; Stefanaki, E.C.; Afouxenidis, D.; Tsirliganis, N.C.; Kitis, G.

    2008-01-01

    Al 2 O 3 :C single crystals are known to exhibit different, sample dependent, glow-curve shapes. The relation between the Thermoluminescence (TL) traps and the linear modulated optically stimulation luminescence (LM-OSL) traps is of high importance. In the present work a correlation study is attempted using 23 single crystals with dimensions between 400 and 500μm. The correlation study involved two steps. In the first step, both TL glow curves and LM-OSL decay curves are deconvoluted and a one-to-one correlation between TL peaks and LM-OSL components is attempted. In the second step the TL glow-curves are corrected for thermal quenching, the corrected curves are deconvoluted and a new correlation between TL and LM-OSL individual components is performed

  17. Clinical application of 201Tl scintigraphy in patients with cold thyroid nodules

    International Nuclear Information System (INIS)

    Tonami, N.; Bunko, H.; Michigishi, T.; Kuwajima, A.; Hisada, K.

    1978-01-01

    201 Tl-chloride scintigraphy was performed in 45 patients with cold thyroid nodules. The 201 Tl scintigram was positive in 17 of 18 thyroid patients with cancer (94.4%), 8 of 20 patients with an adenoma (40.0%), 1 of 2 adenomatous goiter patients (50.5%), and all of 5 cases of chronic thyroiditis (100.0%). When the cold nodule was demonstrated to be positive with 201 Tl, the statistical chance of the lesion being a cellular one was 100.0% and a risk of its malignancy was 54.8%. On the other hand, the nodule with negative 201 Tl concentration had a 14.3% chance of cellularity and a 7.1% risk of malignancy. Thus, 201 Tl scintigraphy is of use in the differential diagnosis of the cold thyroid nodule

  18. Comparison of functional parameters of CsI:Tl crystals and thick films

    International Nuclear Information System (INIS)

    Fedorov, A.; Gektin, A.; Lebedynskiy, A.; Mateychenko, P.; Shkoropatenko, A.

    2013-01-01

    500 mkm thick CsI:Tl columnar films can be produced using thermal evaporation in vacuum by sublimation of the same bulk crystal. Comparison of afterglow and radiation stability of deposited CsI:Tl films with source crystal was the aim of current work. It is shown that the afterglow in the films is always below its level in initial single crystal. It was ascertained that the annealing atmospheres influence the processes leading to the activator depletion of the films during the thermal processing. -- Highlights: ► Thick CsI:Tl columnar films were obtained by thermal evaporation in vacuum. ► Radiation stability of such CsI:Tl films appears to be better than that of crystal. ► CsI:Tl film parameters can be modified by annealing in different atmospheres

  19. Absolute leukocyte telomere length in HIV-infected and uninfected individuals: evidence of accelerated cell senescence in HIV-associated chronic obstructive pulmonary disease.

    Directory of Open Access Journals (Sweden)

    Joseph C Y Liu

    Full Text Available Combination antiretroviral therapy (cART has extended the longevity of human immunodeficiency virus (HIV-infected individuals. However, this has resulted in greater awareness of age-associated diseases such as chronic obstructive pulmonary disease (COPD. Accelerated cellular senescence may be responsible, but its magnitude as measured by leukocyte telomere length is unknown and its relationship to HIV-associated COPD has not yet been established. We measured absolute telomere length (aTL in peripheral leukocytes from 231 HIV-infected adults. Comparisons were made to 691 HIV-uninfected individuals from a population-based sample. Subject quartiles of aTL were assessed for relationships with measures of HIV disease severity, airflow obstruction, and emphysema severity on computed tomographic (CT imaging. Multivariable regression models identified factors associated with shortened aTL. Compared to HIV-uninfected subjects, the mean aTL in HIV-infected patients was markedly shorter by 27 kbp/genome (p<0.001; however, the slopes of aTL vs. age were not different (p=0.469. Patients with longer known durations of HIV infection (p=0.019 and lower nadir CD4 cell counts (p=0.023 had shorter aTL. Shorter aTL were also associated with older age (p=0.026, smoking (p=0.005, reduced forced expiratory volume in one second (p=0.030, and worse CT emphysema severity score (p=0.049. HIV-infected subjects demonstrate advanced cellular aging, yet in a cART-treated cohort, the relationship between aTL and age appears no different from that of HIV-uninfected subjects.

  20. Multi-band Monopole Antennas Loaded with Metamaterial TL

    Science.gov (United States)

    Song, Zhi-jie; Liang, Jian-gang

    2015-05-01

    A novel metamaterial transmission line (TL) by loading complementary single Archimedean spiral resonator pair (CSASRP) is investigated and used to design a set of multi-frequency monopole antennas. The particularity is that the CSASRP which features dual-shunt branches in the equivalent circuit model is directly etched in the signal strip. By smartly controlling the element parameters, three antennas are designed and one of them covering UMTS and Bluetooth bands is fabricated and measured. The antenna exhibits impedance matching better than -10 dB and normal monopolar radiation patterns at working bands of 1.9-2.22 and 2.38-2.5 GHz. Moreover, the loaded element also contributes to the radiation, which is the major advantage of this prescription over previous lumped-element loadings. The proposed antenna is also more compact over previous designs.

  1. Superdeformed bands in Hg and Tl nuclei for N≤112

    International Nuclear Information System (INIS)

    Carpenter, M.P.; Jannsens, R.V.F.; Liang, Y.; Ahmad, I.; Henry, R.; Khoo, T.L.; Lauritsen, T.; Soramel, F.; Lewis, J.M.; Riedinger, L.L.; Yu, C.H.; Garg, U.; Reviol, W.; Pilotte, S.; Bearden, I.G.; Daly, P.J.

    1992-01-01

    The study of superdeformed (SD) nuclei in the A ∼ 190 region has provided a wealth of new information on SD states at moderate to high spins (I ∼ 10 to 50 h). The dynamical moment of inertia for almost all of the SD bands reported on to date in this mass region display a similar behavior, i.e. a smooth increase with increasing rotational frequency. This increase has been attributed to both quasiparticle alignments and a decrease in pairing with increasing rotational frequency. However, standard mean-field calculations have problems reproducing the magnitude and extent of the rise. The authors' recent results on SD states in the Hg-Tl nuclei at and below the N = 112 SD-gap add support to this interpretation of the rise in the dynamical moment of inertia while at the same time showing more clearly the inadequacies of the previous theoretical calculations

  2. Retrospective dosimetry using EPR and TL techniques: a status report

    International Nuclear Information System (INIS)

    Haskell, E.H.

    1996-01-01

    Methods of retrospective dosimetry, including luminescence and electron paramagnetic resonance spectroscopy (EPR), rely on measurement of accident dose absorbed by naturally occurring materials - ceramics in the case of both thermoluminescence (TL) and optically stimulated luminescence (OSL) and organic materials and bio- minerals in the case of EPR. Each of these methods relies on measurement of radiation defects resulting from accidental exposure. Since defects also result from natural sources of radiation over the lifetime of a sample, analysis is usually restricted to materials for which the natural dose may be determined and subtracted from the measured cumulative dose. Luminescence dating techniques rely heavily on an accurate assessment of cumulative dose from natural radiation sources, and dating research has provided us with the bulk of our knowledge in this area. Virtually all of the work on natural dose determination can be directly applied to retrospective techniques. With EPR techniques the cumulative dose from diagnostic x- rays is also of importance

  3. A new type of spurious reading in TL personnel monitoring

    International Nuclear Information System (INIS)

    Duftschmid, K.E.; Stadtmann, H.; Strachotinsky, Ch.; Winker, N.

    1996-01-01

    A particularly serious type of spurious reading in automated TL personnel monitoring has been observed. These readings simulate dose values up to several mSv and can only be detected by glow curve analysis. Characteristics for these events are high artifical dose values and irregular glow curves of a particular shape. Extensive investigations to reproduce this effect purposely failed to produce any results. It can be assumed, however, that it must be some chemical surface contamination, which penetrates the sealed dosemeter bag or which is transferred from the bag to the detector. The effect can be eliminated by manual cleaning of the dosemeter cards. The importance of this observation lies in the fact that only proper glow curve evaluation can prevent the monitoring service from reporting artificial high dose readings creating lots of serious problems. The paper shows how this problem can be avoided for this kind of spurious effect, if glow curves are available and stored for every dosemeter readout. (author)

  4. Giant Rashba spin splitting in Bi2Se3: Tl

    KAUST Repository

    Singh, Nirpendra

    2014-07-25

    First-principles calculations are employed to demonstrate a giant Rashba spin splitting in Bi2Se3:Tl. Biaxial tensile and compressive strain is used to tune the splitting by modifying the potential gradient. The band gap is found to increase under compression and decreases under tension, whereas the dependence of the Rashba spin splitting on the strain is the opposite. Large values of αR = 1.57 eV Å at the bottom of the conduction band (electrons) and αR = 3.34 eV Å at the top of the valence band (holes) are obtained without strain. These values can be further enhanced to αR = 1.83 eV Å and αR = 3.64 eV Å, respectively, by 2% tensile strain. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. Core excitations across the neutron shell gap in 207Tl

    Directory of Open Access Journals (Sweden)

    E. Wilson

    2015-07-01

    Full Text Available The single closed-neutron-shell, one proton–hole nucleus 207Tl was populated in deep-inelastic collisions of a 208Pb beam with a 208Pb target. The yrast and near-yrast level scheme has been established up to high excitation energy, comprising an octupole phonon state and a large number of core excited states. Based on shell-model calculations, all observed single core excitations were established to arise from the breaking of the N=126 neutron core. While the shell-model calculations correctly predict the ordering of these states, their energies are compressed at high spins. It is concluded that this compression is an intrinsic feature of shell-model calculations using two-body matrix elements developed for the description of two-body states, and that multiple core excitations need to be considered in order to accurately calculate the energy spacings of the predominantly three-quasiparticle states.

  6. Retrospective dosimetry using EPR and TL techniques: a status report

    Energy Technology Data Exchange (ETDEWEB)

    Haskell, E.H.

    1996-12-31

    Methods of retrospective dosimetry, including luminescence and electron paramagnetic resonance spectroscopy (EPR), rely on measurement of accident dose absorbed by naturally occurring materials - ceramics in the case of both thermoluminescence (TL) and optically stimulated luminescence (OSL) and organic materials and bio- minerals in the case of EPR. Each of these methods relies on measurement of radiation defects resulting from accidental exposure. Since defects also result from natural sources of radiation over the lifetime of a sample, analysis is usually restricted to materials for which the natural dose may be determined and subtracted from the measured cumulative dose. Luminescence dating techniques rely heavily on an accurate assessment of cumulative dose from natural radiation sources, and dating research has provided us with the bulk of our knowledge in this area. Virtually all of the work on natural dose determination can be directly applied to retrospective techniques. With EPR techniques the cumulative dose from diagnostic x- rays is also of importance.

  7. Non-radiation induced signals in TL dosimetry

    International Nuclear Information System (INIS)

    German, U.; Weinstein, M.

    2002-01-01

    One source of background signals, which are non-radiation related, is the reader system and it includes dark current, external contaminants and electronic spikes. These factors can induce signals equivalent to several hundredths of mSv. Mostly, the effects are minimised by proper design of the TLD reader, but some effects are dependent on proper operation of the system. The other main group of background signals originate in the TL crystal and is due to tribothermoluminescence, dirt, chemical reactions and stimulation by visible or UV light. These factors can have a significant contribution, equivalent to over several mSv, depending on whether the crystal is bare or protected by PTFE. Working in clean environments, monitoring continuously the glow curve and performing glow curve deconvolution are suggested to minimise non-radiation induced spurious signals. (author)

  8. CsI(Tl) with photodiodes for identifying subsurface radionuclide contamination

    International Nuclear Information System (INIS)

    Stromswold, D.C.; Meisner, J.E.; Nicaise, W.F.

    1994-10-01

    At the US Department of Energy's Hanford Site near Richland, Washington, underground radioactive contamination exists as the result of leaks, spills, and intentional disposal of waste products from plutonium-production operations. Characterizing these contaminants in preparation for environmental remediation is a major effort now in progress. In this paper, a cylindrical (15 x 61 mm) CsI(Tl) scintillation detector with two side-mounted photodiodes has been developed to collect spectral gamma-ray data in subsurface contaminated formations at the U.S. Department of Energy's Hanford Site. It operates inside small-diameter, thick-wall steel pipes pushed into the ground to depths up to 20 m by a cone penetrometer. The detector provides a rugged, efficient, magnetic-field-insensitive means for identifying gamma-ray-emitting contaminants (mainly 137 Cs and 60 Co). Mounting two 3 x 30-mm photodiodes end-to-end on a flat area along the detector's side provides efficient light collection over the length of the detector

  9. Clinical use of /sup 201/Tl myocardial scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Senda, K; Imaeda, T; Kato, T; Asada, S; Doi, H

    1977-04-01

    Myocardial imaging with /sup 201/Tl and scinticamera was studied experimentally using specially designed phantoms and clinically in 23 patients with myocardial infarction or other heart disease. In the phantom experiment, quality of image, accumulative count rate, and detectability of the defect were compared to obtain the best technique for their detection, using four different collimators, i.e., converging, pin-hole, 4000-hole, and 140 keV high-resolution, at two photopeak levels of /sup 201/Tl of 75 and 167 keV, and combining a radiation absorber. In patient examination, myocardial images taken at different periods after injection, different detecting conditions of the scinticamera, and various detecting projections were compared. Images of the converging collimator at the 75 keV photopeak revealed considerably higher accumulative counts and relatively higher quality than those of other detecting conditions. It was necessary to take as many images as possible in various projections, in order to detect the location and size of the myocardial ischemic lesion because the lesion was demonstrated as a clear defect only in profile. It became evident that images taken between about 25 and 90 min delineated the myocardium more clearly than those taken in other periods. Normal images taken in 8 patients without ischemic heart disease appeared in the shape of a doughnut of horseshoe, demonstrating mainly the left venticular myocardium. The image was faint in the region of the aortic or mitral valve and thin in the region of the apical wall. A faint image of the right ventricular myocardium was sometimes seen. In 3 patients with valvular heart disease, findings suggested changes in the thickness of myocardium and the distribution of coronary blood flow. In 11 of 12 patients with old myocardial infarction, the location and size of the lesion was detected.

  10. Extended fuel cycle length

    International Nuclear Information System (INIS)

    Bruyere, M.; Vallee, A.; Collette, C.

    1986-09-01

    Extended fuel cycle length and burnup are currently offered by Framatome and Fragema in order to satisfy the needs of the utilities in terms of fuel cycle cost and of overall systems cost optimization. We intend to point out the consequences of an increased fuel cycle length and burnup on reactor safety, in order to determine whether the bounding safety analyses presented in the Safety Analysis Report are applicable and to evaluate the effect on plant licensing. This paper presents the results of this examination. The first part indicates the consequences of increased fuel cycle length and burnup on the nuclear data used in the bounding accident analyses. In the second part of this paper, the required safety reanalyses are presented and the impact on the safety margins of different fuel management strategies is examined. In addition, systems modifications which can be required are indicated

  11. Total algorithms

    NARCIS (Netherlands)

    Tel, G.

    We define the notion of total algorithms for networks of processes. A total algorithm enforces that a "decision" is taken by a subset of the processes, and that participation of all processes is required to reach this decision. Total algorithms are an important building block in the design of

  12. Relativistic distances, sizes, lengths

    International Nuclear Information System (INIS)

    Strel'tsov, V.N.

    1992-01-01

    Such notion as light or retarded distance, field size, formation way, visible size of a body, relativistic or radar length and wave length of light from a moving atom are considered. The relation between these notions is cleared up, their classification is given. It is stressed that the formation way is defined by the field size of a moving particle. In the case of the electromagnetic field, longitudinal sizes increase proportionally γ 2 with growing charge velocity (γ is the Lorentz-factor). 18 refs

  13. The TL,NO/TL,CO ratio in pulmonary function test interpretation.

    Science.gov (United States)

    Hughes, J Michael B; van der Lee, Ivo

    2013-02-01

    The transfer factor of the lung for nitric oxide (T(L,NO)) is a new test for pulmonary gas exchange. The procedure is similar to the already well-established transfer factor of the lung for carbon monoxide (T(L,CO)). Physiologically, T(L,NO) predominantly measures the diffusion pathway from the alveoli to capillary plasma. In the Roughton-Forster equation, T(L,NO) acts as a surrogate for the membrane diffusing capacity (D(M)). The red blood cell resistance to carbon monoxide uptake accounts for ~50% of the total resistance from gas to blood, but it is much less for nitric oxide. T(L,NO) and T(L,CO) can be measured simultaneously with the single breath technique, and D(M) and pulmonary capillary blood volume (V(c)) can be estimated. T(L,NO), unlike T(L,CO), is independent of oxygen tension and haematocrit. The T(L,NO)/T(L,CO) ratio is weighted towards the D(M)/V(c) ratio and to α; where α is the ratio of physical diffusivities of NO to CO (α=1.97). The T(L,NO)/T(L,CO) ratio is increased in heavy smokers, with and without computed tomography evidence of emphysema, and reduced in the voluntary restriction of lung expansion; it is expected to be reduced in chronic heart failure. The T(L,NO)/T(L,CO) ratio is a new index of gas exchange that may, more than derivations from them of D(M) and V(c) with their in-built assumptions, give additional insights into pulmonary pathology.

  14. Study of TL and optically stimulated luminescence of K{sub 2}Ca{sub 2}(SO{sub 4}){sub 3}:Cu nanophosphor for radiation dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Mandlik, Nandkumar [Department of Physics, University of Pune, Pune 411007 (India); Department of Physics, Ferguson College, Pune 411004 (India); Sahare, P.D. [Department of Physics and Astrophysics, University of Delhi, Delhi 110007 (India); Kulkarni, M.S. [Radiological Physics and Advisory Division, BARC, Mumbai 400085, Maharashtra (India); Bhatt, B.C. [Radiation Safety Systems Division, BARC, Mumbai 400085, Maharashtra (India); Bhoraskar, V.N. [Department of Physics, University of Pune, Pune 411007 (India); Dhole, S.D., E-mail: sanjay@physics.unipune.ac.in [Department of Physics, University of Pune, Pune 411007 (India)

    2014-02-15

    Nanocrytstalline K{sub 2}Ca{sub 2}(SO{sub 4}){sub 3}:Cu phosphor was synthesized by the chemical co-precipitation method and annealed at different temperatures (400–900 °C) for 2 h. The XRD spectrum shows the cubic structure with crystallite size ∼20 nm. The same was also confirmed from the TEM image which shows the formation of nanorods having diameter ∼20 nm and length of ∼200 nm. They are found to be quite uniform in shapes and sizes. These samples were irradiated with gamma radiation for the doses varying from 0.01 Gy to 10 kGy and their thermoluminescence (TL) characteristics and continuous wave optically stimulated luminescence (CW-OSL) have been studied. The sample annealed at 700 °C was found to be most sensitive than others. The glow curves of the nanophosphor show a major peak at around 175 °C and other two peaks of low intensity at around 85 °C and 305 °C. The traps responsible for the three thermoluminescence peaks in K{sub 2}Ca{sub 2}(SO{sub 4}){sub 3}:Cu are also found to be sensitive to the OSL. The qualitative correlation between TL peaks and CW-OSL response is established. The TL response of the sample annealed at 700 °C for 2 h and irradiated with different gamma doses shows a linear behavior from 0.01 up to 300 Gy and become sublinear in the range of 300 Gy–1 kGy before it saturates with further increase in the dose, while, the OSL response of the same sample shows linearity up to 1 kGy. Simple glow curve structure, easy method of synthesis, and linear dose response make the nanocrystalline phosphor a good candidate for radiation dosimetry, especially for the estimation of high doses of gamma rays where the microcrystalline phosphors generally saturate. -- Highlights: • Nanocrytstalline K{sub 2}Ca{sub 2}(SO{sub 4}){sub 3}:Cu phosphor was synthesized by the chemical co-precipitation method. • Thermoluminescence (TL) and continuous wave optically stimulated luminescence (CW-OSL) characteristics have been studied. • The TL glow

  15. Trithallium tetraselenophosphate Tl3PSe4, and trithallium tetrathioarsenate, Tl3AsS4, by neutron time-of-flight diffraction

    International Nuclear Information System (INIS)

    Alkire, R.W.; Vergamini, P.J.; Larson, A.C.; Morosin, B.

    1984-01-01

    Room-temperature (293 K) single-crystal structure determinations of the isostructural materials Tl 3 PSe 4 and Tl 3 AsS 4 were performed at the Los Alamos National Laboratory Pulsed Neutron Facility. For Tl 3 PSe 4 : Msub(r) = 959.92, Pcmn, a = 9.276 (1), b = 11.036 (2), c = 9.058 (1) A, V = 927.27 A 3 , Z = 4, Dsub(m) = 6.87 (2), Dsub(x) = 6.876 Mg m -3 , lambdasub(neutron) = 0.5 → 5.2 A, F(000) = 252.5 fm. For Tl 3 AsS 4 : Msub(r) = 816.29, Pcmn, a = 9.084 (3), b = 10.877 (3), c = 8.877 (3) A, V = 877.11 A 3 , Z = 4, Dsub(m) = 6.18 (2), Dsub(x) = 6.181 Mg m -3 , lambdasub(neutron) = 0.5 → 5.2 A, F(000) = 177.2 fm. For Tl 3 PSe 4 (Tl 3 AsS 4 ), 1929 (1013) reflections were measured with I > 3sigma(I) and refined by full-matrix least squares to R(F) = 0.061 (0.063). Results on atomic refinement from this study represent an order of magnitude increase in precision over previous single-crystal X-ray structural work using Mo Kα radiation. The PSe 4 3- (AsS 4 3- ) groups have essentially tetrahedral configurations and one Tl + ion shows large anisotropic thermal motion which is structure related. (Auth.)

  16. Preliminary results on TL and OSL aluminium oxide dosimeters developed at IPEN

    Energy Technology Data Exchange (ETDEWEB)

    Fukumori, David T.; Yoshito, Walter K.; Ussui, Valter; Lazar, Dolores R.R.; Campos, Leticia L., E-mail: fukumori@ipen.b [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2011-07-01

    The aluminum oxide composes the modern TL and OSL radiation dosimeters. TL and OSL phenomena are related to chemical elements in the crystalline structure of {alpha}-Al{sub 2}O{sub 3}. The aim of this work was to develop materials based on aluminum oxide for use in TL and OSL dosimetry. The studies included the dosimetric properties of alumina samples obtained by electro fusion, adsorption and coprecipitation. Electro fused alumina commercially available as abrasive particles was used to produce the pellets by glass sintering. Adsorption and coprecipitation were the methods used to insert metal ions to alumina. The best results were achieved with electro fused alumina and Tm{sup 3+} doped Al{sub 2}O{sub 3} pellets. The electro fused alumina-glass pellets show TL and OSL signals and the TL curve has two peaks. Its minimum detectable radiation dose is 7.2 mGy and the linearity of TL response as function of dose is up to about 800 mGy. The {alpha}-Al{sub 2}O{sub 3}:Tm pellets produced by sintering at 1550 deg C presented a meaningful TL glow curve so that it is worth studying their properties and viability of use in dosimetry. (author)

  17. The usefulness of [sup 201]TlCl scintigraphy for the diagnosis of breast tumor

    Energy Technology Data Exchange (ETDEWEB)

    Takahashi, Tamami; Moriya, Etsuo; Miyamoto, Yukio; Kawakami, Kenji; Kubo, Hirotaka; Uchida, Takeshi [Jikei Univ., Tokyo (Japan). School of Medicine

    1994-06-01

    The usefulness of [sup 201]TlCl SPECT (Tl SPECT) for the diagnosis of breast cancer was evaluated in 14 patients with various breast tumors (9 with invasive ductal carcinoma, 2 with fibroadenoma and 3 with benign process). These tumors ranged in size from 1.5 cm x 1.5 cm to 15.0 cm x 14.0 cm. Tl SPECT was carried out 2 hours after the intravenous injection of [sup 201]TlCl (185 MBq). For quantitative study, ROIs were set in the tumor (T), normal tissue of the opposite breast (B) and myocardium (M). Count ratios of T/B and T/M were calculated. Eight patients with breast cancer and a case of fibroadenoma showed intense accumulation of [sup 201]TlCl in the tumors. The T/B ratio was 1.20[+-]0.68 and the T/M ratio was 0.68[+-]0.31 in the 9 cases. Lymph node metastasis was detected in 2 of 6 cases that were confirmed at operation. No remarkable accumulation of [sup 201]TlCl was seen in 4 patients with benign process. One patient with benign tumor showed a false positive result. The rates of accuracy of mammography and ultrasonography for the same subjects were 82% and 84%, respectively. The results suggest that [sup 201]TlCl SPECT might be useful to assess breast cancer in cases in which the findings of other modalities are equivocal. (author).

  18. Myocardial 201Tl washout after combined dipyridamole submaximal exercise stress: Reference values from different patient groups

    International Nuclear Information System (INIS)

    Fridrich, L.

    1989-01-01

    Dipyridamole stress is favorable in patients unable to exercise maximally for 201 Tl myocardial scintigraphy. Aside from an analysis of uptake defects, proper washout analysis can be limited by heart rate variations when isolated dipyridamole stress is used. Heart rate standardized 201 Tl washout kinetics after a combined dipyridamole and submaximal exercise stress protocol (CDSE), feasible in elderly patients as well as in patients with peripheral artery disease, were therefore studied to investigate the 201 Tl washout after CDSE in differently defined patient groups: Group I comprised 19 patients with documented heart disease and angiographically excluded coronary artery disease (CAD); group II contained 17 patients with a very low likelihood of CAD determined by both normal exercise radionuclide ventriculography and normal 201 Tl uptake. Group III comprised 56 patients with a 50% pretest likelihood of CAD but normal 201 Tl uptake. Mean washout values were nearly identical in all groups. Despite similar uptake patterns, however, washout standardized by CDSE was significantly lower than the normal washout values after maximal treadmill exercise. Thus an obviously lower 201 Tl washout after CDSE than after maximal treadmill exercise must be considered if washout analysis criteria after dipyridamole are applied to evaluate ischemic heart disease. Nevertheless, heart rate elevation achieved by additional submaximal exercise stress seems necessary, adequate and clinically safe for standardisation of washout analysis in dipyridamole 201 Tl scintigraphy. (orig.)

  19. Dipyridamole 201Tl scintigraphy in the evaluation of prognosis after myocardial infarction

    International Nuclear Information System (INIS)

    Okada, R.D.; Glover, D.K.; Leppo, J.A.

    1991-01-01

    Dipyridamole 201Tl imaging has been proposed as an alternative to exercise ECG testing for the prehospital discharge evaluation of patients recovering from myocardial infarction. The rationale is that many postinfarction patients with exercise-induced ischemia experience later cardiac events, and the sensitivity of predischarge exercise ECG testing in patients with multivessel disease ranges from only 45% to 62%. In addition, several groups of investigators have shown the sensitivity of submaximum exercise 201Tl imaging to be less than ideal. This report summarizes the current status of dipyridamole 201Tl imaging in the period of 1-13 days after myocardial infarction. Although the number of studies performed to date is limited, the following conclusions can be drawn: dipyridamole 201Tl imaging after myocardial infarction was associated with no serious side effects, and those present could be quickly reversed with aminophylline; redistribution with dipyridamole 201Tl images definitely correlates with prognosis after uncomplicated myocardial infarction; dipyridamole 201Tl imaging is definitely useful in patients unable to exercise for a variety of reasons; and future studies are definitely indicated to further define the role of dipyridamole 201Tl imaging for assessing prognosis, especially in those patients undergoing interventional therapy after acute myocardial infarction

  20. Usefulness of 201Tl myocardial scintigraphy after dipyridamole infusion in patients with atherosclerotic vascular disease

    International Nuclear Information System (INIS)

    Toyama, Takuji; Nishimura, Tsunehiko; Uehara, Toshiisa

    1992-01-01

    To determine the utility for detecting ischemic heart disease (IHD), dipyridamole thallium myocardial images (DIP-Tl) have been performed in 103 patients with atherosclerotic vascular disease who can't exercise fully. Of the 103 patients, there were 36 patients with arteriosclerosis obliterans (ASO), 31 patients with aneurysm of the abdominal aorta (AAA), 24 patients with aneurysm of the thoracic aorta (TAA) and 12 patients with dissecting aortic aneurysm (DAA). Clinical evidence of IHD was found in 20 patients with ASO, 10 with AAA, 7 with TAA and 4 with DAA. Positive evidence of DIP-Tl was identified in 66% of 41 patients who had clinical evidence of IHD, and particularly in the patients with AAA (80%) and ASO (65%). On the other hand, in the patients without clinical evidence of IHD, positive evidence of DIP-Tl was identified in 19% of 62 patients and particularly in the patients with AAA (39%). In all patients, the percentage of the positive DIP-Tl ratio was 38%. And, when the 38% patients of the positive DIP-Tl were added to the patients of the negative DIP-Tl who had clinical evidence of IHD, almost half patients (51%) were considered to be complicated with IHD. This study suggests that the atherosclerotic vascular disease is highly complicated with IHD and DIP-Tl is useful to detect IHD. (author)

  1. Significance of Tl-201 redistribution on infarcted region assessed by coronary sinus flow and lactate metabolism

    International Nuclear Information System (INIS)

    Mori, Takao; Yamabe, Hiroshi; Suda, Kenichirou; Ohnishi, Masataka; Shiotani, Hideyuki; Kurimoto, Yasuyuki; Kobayashi, Katsuya; Maeda, Kazumi; Fukuzaki, Hisashi

    1987-01-01

    To clarify the significance of Tl-201 redistribution on infarcted regions, coronary sinus and great cardiac vein flow response and lactate metabolism assessed by Webster catheter on 14 infarcted regions after dipyridamole administration were compared with Tl-201 redistribution phenomenon. The regional coronary flow response and lactate extraction ratio in 11 regions with Tl-201 redistribution were lower than those in 3 regions without Tl-201 redistribution. Only 5 regions in 11 with Tl-201 redistribution showed lactate production. The coronary flow response in 5 regions with lactate production was not different from those in 6 without lactate production (1.16 ± 0.89 vs. 1.47 ± 0.67; n.s.). The degree of Tl-201 redistribution assessed by relative activity was not different between regions with and without lactate production. The left ventricular end-diastolic pressure elevated in 5 regions with lactate production (17.8 ± 5.4 mmHg to 29.6 ± 4.9 mmHg; p < 0.05), but didn't in 6 regions without lactate production. Five regions with lactate production contained 4 hypokinetic regions, on the other hand 6 regions without lactate production contained only 3 hypokinetic regions. In conclusion, Tl-201 redistribution on infarcted region revealed not only ischemia but also decreased coronary flow response without lactate production and/or left ventricular dysfunction. (author)

  2. Estimating distribution parameters of annual maximum streamflows in Johor, Malaysia using TL-moments approach

    Science.gov (United States)

    Mat Jan, Nur Amalina; Shabri, Ani

    2017-01-01

    TL-moments approach has been used in an analysis to identify the best-fitting distributions to represent the annual series of maximum streamflow data over seven stations in Johor, Malaysia. The TL-moments with different trimming values are used to estimate the parameter of the selected distributions namely: Three-parameter lognormal (LN3) and Pearson Type III (P3) distribution. The main objective of this study is to derive the TL-moments ( t 1,0), t 1 = 1,2,3,4 methods for LN3 and P3 distributions. The performance of TL-moments ( t 1,0), t 1 = 1,2,3,4 was compared with L-moments through Monte Carlo simulation and streamflow data over a station in Johor, Malaysia. The absolute error is used to test the influence of TL-moments methods on estimated probability distribution functions. From the cases in this study, the results show that TL-moments with four trimmed smallest values from the conceptual sample (TL-moments [4, 0]) of LN3 distribution was the most appropriate in most of the stations of the annual maximum streamflow series in Johor, Malaysia.

  3. Thin-layer agar (TL7H11 for rapid isolation of Mycobacterium tuberculosis in sputum specimens

    Directory of Open Access Journals (Sweden)

    Habiba Binte Alam

    2016-08-01

    Full Text Available Background: Tuberculosis (TB remains one of the major causes of death from a single infectious agent worldwide. The early detection of new cases of pulmonary tuberculosis is an important goal in tuberculosis control program.Objective: 1n this study, thin layer agar (TLA culture was compared with Lowenstein-Jensen (LJ culture for rapid detection of pulmonary tuberculosis. Methods: It was a cross sectional study conducted in National Tuberculosis Reference Labora­tory (NTRL of National Institute of Disease of Chest and Hospital (NIDCH, Dhaka, from July 2010 to June 2011. A total of 100 sputum smear positive for acid fast bacilli (AFB by Z-N staining, pulmonary tuberculosis patients were included in this study. Samples were processed by modified Petroff method and then cultured on thin layer 7H11(TL7H11 plates and L-J tubes. TL7H11 plates were observed microscopically for rnicrocolony growth once a week for 6 weeks, and L-J tubes were observed once a week for 8 weeks. Results: The recovery rates of mycobacteria on only TLA, only LJ and on both media were 90%, 97% and 88% respectively. Overall positivity was 99% in both L-J and TLA media. Mean time for detection of mycobacteria on TLA was 9.04±1.66 days compared to 21.78±6.19 days on L-J media. The rate of contamination was higher (6% in L-J media than in TLA media (4%. Conclusion: The TL7H11 media can be used as an alternative to the Lowenstein-Jensen medium for early isolation of mycobacteria in resource constrained settings.

  4. A Ge(Li)-NaI(Tl) Compton-suppression spectrometer for in-beam γ-ray spectroscopy, ch. 2

    International Nuclear Information System (INIS)

    Driel, M.A. van; Hoogenboom, A.M.

    1976-01-01

    A Compton-suppression spectrometer has been constructed for in-beam γ-ray work. It consists of a closed-end Ge(Li) detector with an efficiency of 21% and a resolution of 2.0 keV for 1.33 MeV γ-rays surrounded by a NaI(Tl) shield (dia. 230 mm, length 280 mm). The overall Compton-suppression factor for a 60 Co spectrum is 10. Details of the construction are discussed and experimental properties are compared with design calculations

  5. AG, TL, and IRSL dosimetric properties in X-ray irradiated HPHT diamond crystals

    Energy Technology Data Exchange (ETDEWEB)

    Gil-Tolano, M.I. [Programa de Posgrado, Departamento de Investigacion en Fisica, Universidad de Sonora, A. P. 5-088, Hermosillo, Sonora, 83190, Mexico (Mexico); Melendrez, R.; Lancheros-Olmos, J.C.; Soto-Puebla, D.; Chernov, V.; Pedroza-Montero, M.; Barboza-Flores, M. [Departamento de Investigacion en Fisica, Universidad de Sonora, A. P. 5-088, Hermosillo, Sonora, 83190, Mexico (Mexico); Castaneda, B. [Departamento de Fisica, Universidad de Sonora, Blvd. Luis Encinas y Rosales S/N, Hermosillo, Sonora, 83000, Mexico (Mexico)

    2014-10-15

    HPHT diamonds have been studied for several years for their potential in different applications. In previous studies it has been found that the thermoluminescence (TL) glow curves of ''as-grown'' HPHT diamonds are non-reproducible. In this work, we study the afterglow (AG), thermoluminescent (TL), and optically stimulated luminescence (OSL) response of commercial samples of synthetic HPHT type-Ib diamond crystals exposed to X-ray irradiation (0.75 mA, 35 kV) at a dose rate of 0.624 Gy/s, after a high gamma ({sup 60}Co) dose irradiation of 500 kGy followed by a thermal treatment at 1073 K for 1 h in nitrogen atmosphere. Deconvolution of the TL glow curves shows four peaks, located around 379, 509, 561, and 609 K. The crystals exhibit evident AG recorded for 300 s immediately after X-ray irradiation, due to the thermal emptying of the traps responsible for the low-temperature TL peaks (below 400 K). The stimulation of irradiated crystals with 870-nm light, creates pronounced OSL and destroys all TL peaks with the exception of the high-temperature peak at 609 K. The dose responses of the integrated AG, TL, and OSL are linear in the range of 0.6-5 Gy and saturated at higher doses. The reproducibility of AG, TL, and OSL measurements is about 5%. The fading in the first hour of storage in dark conditions at RT of TL signal of HPHT diamond is mainly associated to the emptying of the traps responsible for the 379-K TL peaks. (copyright 2014 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  6. Totally James

    Science.gov (United States)

    Owens, Tom

    2006-01-01

    This article presents an interview with James Howe, author of "The Misfits" and "Totally Joe". In this interview, Howe discusses tolerance, diversity and the parallels between his own life and his literature. Howe's four books in addition to "The Misfits" and "Totally Joe" and his list of recommended books with lesbian, gay, bisexual, transgender,…

  7. Pion nucleus scattering lengths

    International Nuclear Information System (INIS)

    Huang, W.T.; Levinson, C.A.; Banerjee, M.K.

    1971-09-01

    Soft pion theory and the Fubini-Furlan mass dispersion relations have been used to analyze the pion nucleon scattering lengths and obtain a value for the sigma commutator term. With this value and using the same principles, scattering lengths have been predicted for nuclei with mass number ranging from 6 to 23. Agreement with experiment is very good. For those who believe in the Gell-Mann-Levy sigma model, the evaluation of the commutator yields the value 0.26(m/sub σ//m/sub π/) 2 for the sigma nucleon coupling constant. The large dispersive corrections for the isosymmetric case implies that the basic idea behind many of the soft pion calculations, namely, slow variation of matrix elements from the soft pion limit to the physical pion mass, is not correct. 11 refs., 1 fig., 3 tabs

  8. Gap length distributions by PEPR

    International Nuclear Information System (INIS)

    Warszawer, T.N.

    1980-01-01

    Conditions guaranteeing exponential gap length distributions are formulated and discussed. Exponential gap length distributions of bubble chamber tracks first obtained on a CRT device are presented. Distributions of resulting average gap lengths and their velocity dependence are discussed. (orig.)

  9. Relativistic length agony continued

    Directory of Open Access Journals (Sweden)

    Redžić D.V.

    2014-01-01

    Full Text Available We made an attempt to remedy recent confusing treatments of some basic relativistic concepts and results. Following the argument presented in an earlier paper (Redžić 2008b, we discussed the misconceptions that are recurrent points in the literature devoted to teaching relativity such as: there is no change in the object in Special Relativity, illusory character of relativistic length contraction, stresses and strains induced by Lorentz contraction, and related issues. We gave several examples of the traps of everyday language that lurk in Special Relativity. To remove a possible conceptual and terminological muddle, we made a distinction between the relativistic length reduction and relativistic FitzGerald-Lorentz contraction, corresponding to a passive and an active aspect of length contraction, respectively; we pointed out that both aspects have fundamental dynamical contents. As an illustration of our considerations, we discussed briefly the Dewan-Beran-Bell spaceship paradox and the ‘pole in a barn’ paradox. [Projekat Ministarstva nauke Republike Srbije, br. 171028

  10. The Use of a Learning Management System (LMS to Serve as the Virtual Common Space of a Network for the Scholarship of Teaching and Learning (SoTL in an Academic Department

    Directory of Open Access Journals (Sweden)

    Scott Merrett

    2013-05-01

    Full Text Available Traditionally, undergraduate curriculum committees, consisting of appointed faculty and student representatives, have served as the sole departmental vehicle for investigating, discussing and promoting the scholarship of teaching and learning (SoTL within an academic department. However, with the universal demand for greater accountability on all aspects of evidence-based teaching and on the totality of student learning and career outcomes, some academic departments have encouraged the formation of additional organizations to support their SoTL mandate. In the Department of Human Health and Nutritional Sciences, the approach taken was to combine the interests of the faculty who had a sustained interest in the “scholarship of knowledge translation and transfer” in the health sciences with those who had a developing interest in SoTL. These faculty members would then form the foundation of a “network” which has been called the K*T3net. The virtual common space of the network is on a Learning Management System (LMS site which is accessed by all faculty members in the network and by a growing number of staff and senior PhD students in the department. The features and potential uses of the K*T3net website will be discussed. The development of the K*T3net has already supported the proposal for a new undergraduate course on SoTL and is opening the possibility for graduate students to add a SoTL component to their thesis research.

  11. SoTL Research Fellows: Collaborative Pathfinding through Uncertain Terrain

    Directory of Open Access Journals (Sweden)

    Elizabeth Marquis

    2017-12-01

    Full Text Available From 2014-2016, Scholarship of Teaching and Learning (SoTL Research Fellows at a mid-sized Canadian research-intensive, medical-doctoral university undertook to study their own formation as scholars of teaching and learning, as well as benefits and challenges of their cross-appointment to our central teaching and learning institute from their home academic departments. Findings from surveys and focus groups identified themes such as identity, community, access, transfer, and structural elements (each with benefits and challenges to practice. Our autoethnographic work confirms assertions in the literature about the uneasy relation between SoTL and traditional scholarship, while also bearing out the need for departmental support, and for key interventions along the path from novice to practitioner identity. Some discussion of the ambassador or translator role that can flow from such arrangements is included. De 2014 à 2016, les chercheurs en Avancement des connaissances en enseignement et en apprentissage (ACEA d’une université canadienne médicale-doctorale de taille moyenne ayant un coefficient de recherche élevé ont entrepris une étude portant sur leur propre formation en tant que chercheurs érudits en matière d’enseignement et d’apprentissage, ainsi que sur les avantages et les défis de leur nomination conjointe à notre institut central d’enseignement et d’apprentissage tout en enseignant dans leur propre département universitaire. Les résultats des sondages et des groupes de discussion ont permis d’identifier certains thèmes tels que l’identité, la communauté, l’accès, le transfert, ainsi que des éléments structuraux (chacun présentant des avantages et des défis concernant la pratique. Notre travail autoethnographique confirme les assertions présentes dans la documentation existante concernant la relation difficile qui existe entre l’ACEA et la recherche traditionnelle, tout en tenant compte de la n

  12. Myocardial scintigraphy with 199Tl chloride for the assessment of antianginal effect of cardil

    International Nuclear Information System (INIS)

    Chernov, V.I.; Mordovin, V.F.; Vesnina, Zh.V.; Triss, S.V.; Bazilevich, I.A.; Lishmanov, Yu.B.

    1995-01-01

    The aim of this research was examination of myocardial perfusion in cardil therapy of twenty-two coronary patients and analysis of potentialities of load 199 Tl scintigraphy in assessment of the antianginal effect in the course of therapy of coronary patients. The findings evidence that due to short 199 Tl half life and low radiation load of the body because of this radionuclide load 199 Tl scintigraphy of the myocardium carried out in the course of therapy of coronary patients may be used as an objective test to assess myocardial perfusion under the effect of treatment. 8 refs

  13. Experimental study on the CsI (Tl) crystal anti-compton detector in CDEX

    International Nuclear Information System (INIS)

    Liu Shukui; Yue Qian; Tang Changjian

    2012-01-01

    CDEX (China Dark matter Experiment) Collaboration will carry out direct search for dark matter with Ultra-Low Energy Threshold High Purity germanium (ULE-HPGe) detector at CJPL (China Jinping deep underground Laboratory). Before underground research, some experiments of the CsI (Tl) crystal Anti-Compton detector have been done on the ground, including light guide choice, wrapping material choice, height uniformity of CsI (Tl) crystal, side uniformity of CsI (Tl) crystal and the test results of all the crystals. Through the preliminary work on the ground, we have got some knowledge of the anti-compton detector and prepared for the underground experiment. (authors)

  14. Tumor and infection localization in AIDS patients: Ga-67 and Tl-201 findings.

    Science.gov (United States)

    Turoglu, H T; Akisik, M F; Naddaf, S Y; Omar, W S; Kempf, J S; Abdel-Dayem, H M

    1998-07-01

    Examples of Ga-67 and Tl-201 scans in AIDS patients performed at St. Vincent's Hospital and Medical Center of New York are presented. Use of these methods is the adopted approach at this institution in AIDS patients for localizing sites of tumor or infection involvement. A Ga-67 scan is the most common nuclear medicine examination performed on AIDS patients. Sequential Tl-201 and Ga-67 scans have a role in differentiating Kaposi's sarcoma from malignant lymphoma and opportunistic infections. For intracranial lesions, Tc-99m MIBI or Tl-201-201-201-201 chloride can differentiate malignant from benign inflammatory lesions.

  15. Experience with TL-102M for the treatment of radiation stomatitis

    International Nuclear Information System (INIS)

    Nishio, Juntaro; Matsuya, Tokuzo; Inoue, Kazuo; Miyazaki, Tadashi; Maeda, Noriaki.

    1984-01-01

    TL-102M was administered to 14 patients who had radiation stomatitis following radiation therapy for malignant tumors in the oral cavity. Regarding the degree of overall improvement, one of the 14 patients was evaluated as ''extremely improved'', eight as ''improved'', four as ''slightly improved'', and one as ''unchanged''. None of the patients had side effects. Adherent, powdered TL-102M was easy to take for patients. Most of the patients desired to continue to take this drug because of having neither painfulness nor adhesive feeling. The usage of TL-102M could be helpful in promoting the treatment for cancer, thus suggesting that it is useful in treating radiation stomatitis. (Namekawa, K.)

  16. Theories of TL systems: Failures, successes, conflicts, trends: Insights into possible future materials and techniques

    International Nuclear Information System (INIS)

    Horowitz, Y. S.; Belaish, Y.; Oster, L.

    2006-01-01

    In this paper some of the many theoretical models dealing with characteristics of TL materials are discussed. Special attention is given to some of the models dealing with the effects of ionisation density, that is Modified Track Structure Theory (MTST) and Micro-dosimetric Track Structure Theory (MTT) for the calculation of Heavy Charged Particle relative TL efficiencies, as well as solid-state models based on conduction band/valence band theory. Failures, successes, conflicts and trends are highlighted as well as a peek into future avenues of research for dosimetric TL materials. (authors)

  17. TL sensitivity of CaSO4:Dy phosphor powder - effect of grinding

    International Nuclear Information System (INIS)

    Shastry, S.S.; Kher, R.K.

    1979-01-01

    Grinding of polycrystalline CaSO 4 :Dy phosphor to powder form induces lattice defects. Changes in thermoluminescence (TL) sensitivity due to variation in trap density in the bulk and on the surface of phosphor grains are studied using gamma and UV radiations. TL sensitivity to gamma increases with grinding time due to the contribution from the new bulk traps which are generated by grinding. The surface traps degrade with increase in grinding time resulting in a decrease in UV sensitivity. Results on regeneration of the TL sensitivity due to annealing at different temperatures are also included. (Auth.)

  18. X-ray photoemission analysis of chemically modified TlBr surfaces for improved radiation detectors

    International Nuclear Information System (INIS)

    Nelson, A. J.; Voss, L. F.; Beck, P. R.; Graff, R. T.; Conway, A. M.; Nikolic, R. J.; Payne, S. A.; Lee, J.-S.; Kim, H.; Cirignano, L.; Shah, K.

    2013-01-01

    We subjected device-grade TlBr to various chemical treatments used in room temperature radiation detector fabrication to determine the resulting surface composition and electronic structure. As-polished TlBr was treated separately with HCl, SOCl 2 , Br:MeOH and HF solutions. High-resolution photoemission measurements on the valence band electronic structure and Tl 4f, Br 3d, Cl 2p and S 2p core lines were used to evaluate surface chemistry and shallow heterojunction formation. Surface chemistry and valence band electronic structure were correlated with the goal of optimizing the long-term stability and radiation response

  19. Radiation Hardness Study of CsI(Tl) Crystals for Belle II Calorimeter

    CERN Document Server

    Matvienko, D V; Sedov, E V; Shwartz, B A

    2017-01-01

    The Belle II calorimeter (at least, its barrel part) consists of CsI(Tl) scintillation crystals which have been used at the Belle experiment. We perform the radiation hardness study of some typical Belle crystals and conclude their light output reductions are acceptable for Belle II experiment where the absorption dose can reach 10 krad during the detector operation. CsI(Tl) crystals have high stablity and low maintenance cost and are considered as possible option for the calorimeter of the future Super-Charm-Tau factory (SCT) in Novosibirsk. Our study demonstrates sufficiently high radiation hardness of CsI(Tl) crystals for SCT conditions.

  20. Evaluation of /sup 201/TlCl and delayed scan for thyroid imaging agent

    Energy Technology Data Exchange (ETDEWEB)

    Taniguchi, Tatsuyoshi; Harada, Taneichi; Takahashi, Tatsuo; Senoo, Tsuneaki; Ohtsuka, Nobuaki; Ito, Yasuhiko [Kawasaki Medical School, Kurashiki, Okayama (Japan)

    1982-11-01

    The results of 189 patients with nodular goiter by imaging with /sup 201/TlCl following with sup(99m)TcO/sub 4//sup -/ was presented. Accumulation of /sup 201/TlCl to the corresponding area was observed in 85.5% of cancer, 62.2% of adenoma, 42.5% of adenomatous goiter, and the usefulness of /sup 201/TlCl (early scan) for thyroid imaging agent was recognized. On the other hand, delayed scan for purpose of differentiation from benign to malignant was also performed. However, no significant differences were obtained.

  1. Offspring telomere length in the long lived Alpine swift is negatively related to the age of their biological father and foster mother.

    Science.gov (United States)

    Criscuolo, François; Zahn, Sandrine; Bize, Pierre

    2017-09-01

    A growing body of studies is showing that offspring telomere length (TL) can be influenced by the age of their parents. Such a relationship might be explained by variation in TL at conception (gamete effect) and/or by alteration of early growth conditions in species providing parental care. In a long-lived bird with bi-parental care, the Alpine swift ( Apus melba ), we exchanged an uneven number of 2 to 4-day-old nestlings between pairs as part of a brood size manipulation. Nestling TL was measured at 50 days after hatching, which allowed investigation of the influence of the age of both their biological and foster parents on offspring TL, after controlling for the manipulation. Nestling TL was negatively related to the age of their biological father and foster mother. Nestling TL did not differ between enlarged and reduced broods. These findings suggest that offspring from older males were fertilized by gametes with shorter telomeres, presumably due to a greater cell division history or a longer accumulation of damage, and that older females may have provided poorer parental care to their offspring. © 2017 The Author(s).

  2. Verification of imported food upon import for radiation processing: Dried herbs, including herbs used in food supplements, and spices by PSL and TL

    Energy Technology Data Exchange (ETDEWEB)

    Boniglia, C. [Department of Veterinary Public Health and Food Safety, Istituto Superiore di Sanita, Rome (Italy)], E-mail: concetta.boniglia@iss.it; Aureli, P. [Department of Veterinary Public Health and Food Safety, Istituto Superiore di Sanita, Rome (Italy); Bortolin, E.; Onori, S. [Department of Technology and Health, Istituto Superiore di Sanita, Rome (Italy)

    2009-07-15

    The Italian National Institute of Health in 2005-2006 performed an analytical survey of import on dried spices and herbs, including herbs used in food supplements, to investigate the entry in Italy of irradiated, and not correctly labelled, raw materials. In this survey, 52 samples, including nine herbal extracts, were collected. The method of photo-stimulated luminescence (PSL) was applied to all samples and only samples screened positive or intermediate with PSL were analysed by using the thermo-luminescence (TL) method. Out of the 12 samples screened positive or intermediate with PSL, the TL method confirmed irradiation of five samples (10% of the total assayed samples). One out of these five samples was a herbal supplement whereas three were herbal extracts that are known to be used as ingredients of herbal supplements, and another one was a spice.

  3. Verification of imported food upon import for radiation processing: Dried herbs, including herbs used in food supplements, and spices by PSL and TL

    International Nuclear Information System (INIS)

    Boniglia, C.; Aureli, P.; Bortolin, E.; Onori, S.

    2009-01-01

    The Italian National Institute of Health in 2005-2006 performed an analytical survey of import on dried spices and herbs, including herbs used in food supplements, to investigate the entry in Italy of irradiated, and not correctly labelled, raw materials. In this survey, 52 samples, including nine herbal extracts, were collected. The method of photo-stimulated luminescence (PSL) was applied to all samples and only samples screened positive or intermediate with PSL were analysed by using the thermo-luminescence (TL) method. Out of the 12 samples screened positive or intermediate with PSL, the TL method confirmed irradiation of five samples (10% of the total assayed samples). One out of these five samples was a herbal supplement whereas three were herbal extracts that are known to be used as ingredients of herbal supplements, and another one was a spice.

  4. Quantitative assessment of 201TlCl myocardial SPECT

    International Nuclear Information System (INIS)

    Uehara, Toshiisa

    1987-01-01

    Clinical evaluation of the quantitative analysis of Tl-201 myocardial tomography by SPECT (Single Photon Emission Computed Tomography) was performed in comparison with visual evaluation. The method of quantitative analysis has been already reported in our previous paper. In this study, the program of re-standardization in the case of lateral myocardial infarction was added. This program was useful mainly for the evaluation of lesions in the left circumflex coronary artery. Regarding the degree of diagnostic accuracy of myocardial infarction in general, quantitative evaluation of myocardial SPECT images was highest followed by visual evaluation of myocardial SPECT images, and visual evaluation of myocardial planar images. However, in the case of anterior myocardial infarction, visual evaluation of myocardial SPECT images has almost the same detectability as quantitative evaluation of myocardial SPECT images. In the case of infero-posterior myocardial infarction, quantitative evaluation was superior to visual evaluation. As for specificity, quantitative evaluation of SPECT images was slightly inferior to visual evaluation of SPECT images. An infarction map was made by quantitative analysis and this enabled us to determine the infarction site, extent and degree according to easily recognizable patterns. As a result, the responsible coronary artery lesion could be inferred correctly and the calculated infarction score could be correlated with the residual left ventricular function after myocardial infarction. (author)

  5. TL studies of calcareous rocks of Danta area, North Gujarat

    International Nuclear Information System (INIS)

    Limaye, M.A.; Desai, S.J.; Murthy, K.V.R.; Joshi, T.R.

    1992-01-01

    The lithounits exposed around Danta in Banaskantha district of North Gujarat belong to Ajabgarh Group, the upper division of the Delhi super group. These rocks are intruded by syn to late kinematic basic rocks and by Erinpura granites of post Delhi age. The Ajabgarh group consists of pelitic and calcareous components. Mineralogically the pelitic rocks comprise cordierite, almandine garnet, k-feldspar, sillimanite, quartz and mica in variable proportions. The calcareous rocks are seen to contain dominantly calcite, scapolite, forsterite, sphene, k-feldspar. These mineral assemblages correspond to upper Amphibolite to lower Granulite facies of regional metamorphism. The chemistry of the calcareous rocks show predominance of CaO over MgO. The glow curves obtained from virgin samples (NTL) as well as artificial beta irradiated indicate glow peaks at 140 o C, 290 o C, 310 o C and 390 o C. The TL glow peak temperatures are in general agreement with those reported by Borsi and Rinaldi and Medlin. The pronounced peak at 390 o C and 290 o C are suggestive of their high irradiation sensitivity and also probably reflect variation in the Mn content of the rocks. (author). 9 refs., 16 tabs., 2 figs

  6. Contributions to a systematic examination of deformed transition nuclei by the study of the decay of 188Tl and 190Tl

    International Nuclear Information System (INIS)

    Waetzig, W.

    1980-01-01

    Using the reaction 197 Au( 3 He,xn) Tl the decay of the nuclides 188 Tl and 190 Tl to 188 Hg (Tsub(1/2) = 70s) respectively to 190 Hg(Tsub(1/2) = 3.0 min) was studied at the mass separator ISOCELE of the Orsay-synchrocyclotron by gamma, conversion electron, gamma-gamma coincidence, and electron-gamma coincidence spectroscopy. The level schemes of 188 Hg and 190 Hg could be remarkably extended in comparison with earlier works. By a statistical analysis of the nuclear level density the nuclear temperature was calculated as a measure for the number of excitation modes of these nuclei. (orig./HSI) [de

  7. 0-6711 : short radius MASH TL-3 guardrail treatment.

    Science.gov (United States)

    2014-11-01

    When a roadway intersects a highway with : restrictive features, such as a bridge rail, it becomes : difficult to fit a guardrail with the proper length, : transitions, and end treatment along the highway. : Possible solutions include relocating the ...

  8. Odd Length Contraction

    Science.gov (United States)

    Smarandache, Florentin

    2013-09-01

    Let's denote by VE the speed of the Earth and byVR the speed of the rocket. Both travel in the same direction on parallel trajectories. We consider the Earth as a moving (at a constant speed VE -VR) spacecraft of almost spherical form, whose radius is r and thus the diameter 2r, and the rocket as standing still. The non-proper length of Earth's diameter, as measured by the astronaut is: L = 2 r√{ 1 -|/VE -VR|2 c2 } rocket! Also, let's assume that the astronaut is laying down in the direction of motion. Therefore, he would also shrink, or he would die!

  9. discouraged by queue length

    Directory of Open Access Journals (Sweden)

    P. R. Parthasarathy

    2001-01-01

    Full Text Available The transient solution is obtained analytically using continued fractions for a state-dependent birth-death queue in which potential customers are discouraged by the queue length. This queueing system is then compared with the well-known infinite server queueing system which has the same steady state solution as the model under consideration, whereas their transient solutions are different. A natural measure of speed of convergence of the mean number in the system to its stationarity is also computed.

  10. Annual dose measurements and TL-dating of ancient Egyptian pottery

    Energy Technology Data Exchange (ETDEWEB)

    Abdel-Wahab, M S; El-Fiki, S A; Abdel-Kariem, S; El-Faramawy, N [Ain Shams University, Cairo (Egypt). Faculty of Science; EL-Fiki, M A [National Institute of Standards, Cairo (Egypt); Gomaa, M [Atomic Energy Establishment, Cairo (Egypt). Nuclear Research Center

    1996-05-01

    In the course of the dating of ancient Egyptian pottery, pottery sherds were collected from three archaeological tombs in Nazlet El Samman region, Giza zone (Egypt). The annual dose from natural background was measured by gamma spectrosocopic technique as well as thermoluminescence (TL) measurements. The results of both methods are in good agreement with a consistency of 99.69%. The extracted quartz exhibited TL dating peaks at about (305 {+-} 5){sup o}C. The TL dating shows an age of 4301 {+-} 100 years for the examined pottery which belongs to the ``Fourth Dynasty`` in the ``OlKingdom`` . The uncertainties in TL dating using the additive method are much lower than that of archaeologists. (author).

  11. Annual dose measurements and TL-dating of ancient Egyptian pottery

    Science.gov (United States)

    Abdel-Wahab, M. S.; El-Fiki, S. A.; El-Fiki, M. A.; Gomaa, M.; Abdel-Kariem, S.; El-Faramawy, N.

    1996-05-01

    In the course of the dating of ancient Egyptian pottery, pottery sherds were collected from three archaeological tombs in Nazlet El Samman region, Giza zone (Egypt). The annual dose from natural background was measured by gamma spectroscopic technique as well as thermoluminescence (TL) measurements. The results of both methods are in good agreement with a consistency of 99.69%. The extracted quartz exhibited TL dating peaks at about(305 ± 5|4)°C. The TL dating shows an age of 4301 ± 100 years for the examined pottery which belongs to the "Fourth Dynasty" in the "Old Kingdom". The uncertainties in TL dating using the additive method are much lower than that of archeologists.

  12. Annual dose measurements and TL-dating of ancient Egyptian pottery

    International Nuclear Information System (INIS)

    Abdel-Wahab, M.S.; El-Fiki, S.A.; Abdel-Kariem, S.; El-Faramawy, N.; Gomaa, M.

    1996-01-01

    In the course of the dating of ancient Egyptian pottery, pottery sherds were collected from three archaeological tombs in Nazlet El Samman region, Giza zone (Egypt). The annual dose from natural background was measured by gamma spectrosocopic technique as well as thermoluminescence (TL) measurements. The results of both methods are in good agreement with a consistency of 99.69%. The extracted quartz exhibited TL dating peaks at about (305 ± 5) o C. The TL dating shows an age of 4301 ± 100 years for the examined pottery which belongs to the ''Fourth Dynasty'' in the ''OlKingdom'' . The uncertainties in TL dating using the additive method are much lower than that of archaeologists. (author)

  13. Study on effects of gamma-ray irradiation on TlBr semiconductor detectors

    International Nuclear Information System (INIS)

    Matsumura, Motohiro; Watanabe, Kenichi; Yamazaki, Atsushi; Uritani, Akira; Kimura, Norihisa; Nagano, Nobumichi; Hitomi, Keitaro

    2016-01-01

    Radiation hardness of thallium bromide (TlBr) semiconductor detectors to 60 Co gamma-ray irradiation was evaluated. The energy spectra and μτ products of electrons were measured to evaluate the irradiation effects. No significant degradation of spectroscopic performance of the TlBr detector for 137 Cs gamma-rays was observed up to 45 kGy irradiation. Although the μτ products of electrons in the TlBr detector slightly decreased, position of the photo-peak was stable without significant degradation after the gamma-ray irradiation. We confirmed that the TlBr semiconductor detector has a high tolerance for gamma-ray irradiation at least up to 45 kGy. (author)

  14. Defects that control the properties of Tl- and Hg-based superconductors

    International Nuclear Information System (INIS)

    Jorgensen, J.D.; Chmaissem, O.; Hinks, D.G.; Mitchell, J.F.; Wagner, J.L.; Univ. of North Dakota, Grand Forks, ND; Jensen, W.R.; Dabrowski, B.; Northern Illinois Univ., DeKalb, IL

    1997-03-01

    Defects that affect T c in Tl 2 Ba 2 CuO 6+δ and HgBa 2 CuO 4+δ and HgBa 2 CuO 4+δ have been characterized by neutron powder diffraction. In Tl 2 Ba 2 CuO 6+δ , the dominant defect is interstitial oxygen between the two Tl-O planes, but Cu substitution on the Tl site also affects properties and there is evidence for a second oxygen defect for compositions in the vicinity of maximum T c . In HgBa 2 CuO 4+δ , there are two competing oxygen defects in the Hg layer. The relative concentrations of these defects switches upon passing from the underdoped region, through the maximum T c , to the overdoped region. This remarkable behavior could result from a change in the topology of the Fermi surface upon passing through the van Hove singularity

  15. Bonding and M?ssbauer Isomer Shifts in (Tl,Pb) - 1223 Cuprate

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    By using the chemical bond theory of dielectric description,the chemical bond parameters of (Tl,Pb) - 1223 was calculated.The results show that the Sr-O,Tl-O,and Ca-O types of bond have higher ionic character and the Cu-O types of bond have more covalent character.M?ssbauer isomer shifts of 57Fe and 119Sn doped in (Tl,Pb) -1223 were calculated by using the chemical environmental factor,he,defined by covalency and electronic polarizability.Four valence state tin and three valence iron sites were identified in 57Fe,and 119Sn doped (Tl,Pb) -1223 superconductor.We conclude that all of the Fe atoms substitute the Cu at square planar Cu (1) site,whereas Sn prefers to substitute the square pyramidal Cu (2) site.

  16. Thallium(I copper(I thorium(IV triselenide, TlCuThSe3

    Directory of Open Access Journals (Sweden)

    James A. Ibers

    2012-07-01

    Full Text Available Thallium(I copper(I thorium(IV triselenide, TlCuThSe3, crystallizes with four formula units in the space group Cmcm in the KCuZrS3 structure type. There is one crystallographically independent Th, Tl, and Cu atom at a site of symmetry 2/m.., m2m, and m2m, respectively. There are two crystallographically independent Se atoms at sites of symmetry m.. and m2m. The structure consists of sheets of edge-sharing ThSe6 octahedra and CuSe4 tetrahedra stacked parallel to the (010 face, separated by layers filled with chains of Tl running parallel to [100]. Each Tl is coordinated by a trigonal prism of Se atoms.

  17. Tl response of KMgF3: Lu + PTFE at ultraviolet radiation

    International Nuclear Information System (INIS)

    Gonzalez, P.R.; Alarcon, N.G.; Furetta, C.; Azorin, J.

    2003-01-01

    Ionizing radiation has different types of interaction with a crystalline solid. However, only few effects are interesting to optimize some thermoluminescent (Tl) properties of certain Tl materials. This paper presents results obtained by irradiating KMgF 3 : Lu + Ptfe Tl dosimeters with ultraviolet (UV) radiation previously exposed to gamma radiation. These results showed that those dosimeters not exposed previously to gamma radiation did not presented any Tl signal. Meanwhile, those previously submitted to gamma irradiation showed that their sensitivity was increased as the gamma dose increased. The glow curve of sensitized KMgF 3 : Lu + Ptfe exposed to UV radiation, presented the dosimetric pea at 212 C. This makes this material to be promissory for measuring UV radiation. (Author)

  18. Enhanced thermoelectric figure of merit in strained Tl-doped Bi2Se3

    KAUST Repository

    Saeed, Y.

    2014-07-21

    We explain recent experimental findings on Tl-doped Bi2Se3 by determining the electronic and transport properties by first-principles calculations and semi-classical Boltzmann theory. Though Tl-doping introduces a momentum-dependent spin-orbit splitting, the effective mass of the carriers is essentially not modified, while the band gap is reduced. Tl is found to be exceptional in this respect as other dopants modify the dispersion, which compromises thermoelectricity. Moreover, we demonstrate that only after Tl-doping strain becomes an efficient tool for enhancing the thermoelectric performance. A high figure of merit of 0.86 is obtained for strong p-doping (7 × 10^20 cm^(−3), maximal power factor) at 500 K under 2% tensile strain.

  19. Evidence for charge Kondo effect in superconducting Tl-doped PbTe

    Energy Technology Data Exchange (ETDEWEB)

    Fisher, I

    2010-01-11

    We report results of low-temperature thermodynamic and transport measurements of Pb{sub 1-x}Tl{sub x}Te single crystals for Tl concentrations up to the solubility limit of approximately x = 1.5%. For all doped samples, we observe a low-temperature resistivity upturn that scales in magnitude with the Tl concentration. The temperature and field dependence of this upturn are consistent with a charge Kondo effect involving degenerate Tl valence states differing by two electrons, with a characteristic Kondo temperature T{sub K} {approx} 6 K. The observation of such an effect supports an electronic pairing mechanism for superconductivity in this material and may account for the anomalously high T{sub c} values.

  20. CsI(Tl)-photodiode detectors for gamma-ray spectroscopy

    CERN Document Server

    Fioretto, E; Viesti, G; Cinausero, M; Zuin, L; Fabris, D; Lunardon, M; Nebbia, G; Prete, G

    2000-01-01

    We report on the performances of CsI(Tl)-photodiode detectors for gamma-ray spectroscopy applications. Light output yield and energy resolution have been measured for different crystals and read-out configurations.

  1. Experimental study on the location of energy windows for scatter correction by the TEW method in 201Tl imaging

    International Nuclear Information System (INIS)

    Kojima, Akihiro; Matsumoto, Masanori; Ohyama, Yoichi; Tomiguchi, Seiji; Kira, Mitsuko; Takahashi, Mutsumasa.

    1997-01-01

    To investigate validity of scatter correction by the TEW method in 201 Tl imaging, we performed an experimental study using the gamma camera with the capability to perform the TEW method and a plate source with a defect. Images were acquired with the triple energy window which is recommended by the gamma camera manufacturer. The result of the energy spectrum showed that backscattered photons were included within the lower sub-energy window and main energy window, and the spectral shapes in the upper half region of the photopeak (70 keV) were not changed greatly by the source shape and the thickness of scattering materials. The scatter fraction calculated using energy spectra and, visual observation and the contrast values measured at the defect using planar images also showed that substantial primary photons were included in the upper sub-energy window. In TEW method (for scatter correction), two sub-energy windows are expected to be defined on the part of energy region in which total counts mainly consist of scattered photons. Therefore, it is necessary to investigate the use of the upper sub-energy window on scatter correction by the TEW method in 201 Tl imaging. (author)

  2. Leukocyte Telomere Length in the Neonatal Offspring of Mothers with Gestational and Pre-Gestational Diabetes.

    Science.gov (United States)

    Gilfillan, Christopher; Naidu, Pratyusha; Gunawan, Florence; Hassan, Fadwa; Tian, Pei; Elwood, Ngaire

    2016-01-01

    Telomeres undergo shortening with cell division, accelerated by increased oxidative stress. We aimed to demonstrate shortened telomeres in the offspring of mothers who have diabetes as a consequence of exposure to increased oxidative stress during intrauterine development. We examined the level of glycaemia (glucose, HbA1c, fructosamine), oxidative stress (lipid peroxidation) and the levels of antioxidant enzymes (Superoxide dismutase (SOD) and Selenium dependent glutathione peroxidase) and correlate these findings with mean telomere length (TL) in maternal and foetal blood in groups of pregnant women with pre-gestational diabetes (PGD), gestational diabetes (GD) and a euglycaemic control group. Foetal and maternal glucose, maternal HbA1c, and foetal insulin and C-peptide were higher in the PGD group with the GD group being intermediate. Markers of oxidative stress did not vary between groups with the exception of foetal SOD activity that was highest in the GD group. There were no detectable differences in maternal or foetal TL between study groups. An exploratory analysis looking at correlations between glycaemic and oxidative stress parameters and TL revealed a negative correlation between maternal and foetal glucose and TL across the whole study population. This relationship held for the short-term marker of glycaemic control, fructosamine. We were unable to show significant telomere shortening in the offspring of mothers with PGD or GD. Exploratory analysis revealed a relationship between foetal TL and short-term glycaemia particularly in PGD. It is possible that increased telomerase activity can compensate for long-term increased oxidative stress but not for short-term dysglycaemia.

  3. Solvent extraction of Tl(I) with 2-mercaptobenzothiazole into chloroform

    International Nuclear Information System (INIS)

    Itawi, R.K.; Turel, Z.R.

    1984-01-01

    The extraction of Tl(I) with 2-mercaptobenzothiazole into chloroform was studied. The effect of various parameters on the extraction coefficient value was evaluated. The stoichiometry of the extracted species obtained from the substoichiometric extraction was found to be 1:1. This was further supported by the slope ratio method. Decontamination factors of a number of elements in the substoichiometric extraction of Tl(I) were also obtained. (author)

  4. TL and OSL studies on undoped diamond films grown by hot filament chemical vapor deposition

    Energy Technology Data Exchange (ETDEWEB)

    Soni, Anuj, E-mail: anujsoni.phy@gmail.com [Radiological Physics and Advisory Division, Bhabha Atomic Research Center, Mumbai 400 085 (India); Choudhary, R.K. [Materials Processing Division, Bhabha Atomic Research Center, Mumbai 400 085 (India); Polymeris, G.S. [Ankara University, Institute of Nuclear Sciences (Turkey); Mishra, D.R. [Radiological Physics and Advisory Division, Bhabha Atomic Research Center, Mumbai 400 085 (India); Mishra, P. [Materials Processing Division, Bhabha Atomic Research Center, Mumbai 400 085 (India); Kulkarni, M.S. [Radiation Safety Systems Division, Bhabha Atomic Research Center, Mumbai 400 085 (India)

    2016-09-15

    In this work, approximately 0.5 µm thick diamond films were grown on a silicon substrate by hot filament chemical vapour deposition (HFCVD) method in a gas mixture of hydrogen and methane. The batch to batch reproducibility of the sample using this technique was found to be very good. The obtained film was characterized by micro laser Raman spectroscopy (MLRS), grazing incidence X-ray diffractometry (GIXRD), scanning electron microscopy (SEM) and atomic force miscroscopy (AFM) techniques. MLRS and GIXRD results confirmed the formation of diamond whereas SEM and AFM analyses indicated uniform morphology of the film with an average grain size of 200 nm. The deposited film was studied for ionizing radiation dosimetry applications using the thermoluminescence (TL) and optically stimulated luminescence (OSL) techniques after irradiating the film by a calibrated 5 mCi, {sup 90}Sr/{sup 90}Y beta source. In the TL measurement, for a heating rate of 4 K/s, broad glow curve was obtained which was deconvoluted into seven TL peaks. The integrated TL counts were found to vary linearly with increasing the radiation dose up to 10 kGy. The characteristic TL output seen in the temperature range 200–300 °C, may be considered good for thermal stability of the film and it could also avoid TL fading during storage and non-interference of any black body radiation during the measurement. However, in comparison to TL output, the OSL response for 470 nm LED stimulation was found to be lesser. The CW–OSL decay curve has shown two components contributing to the OSL signal, having photoionization cross-section 1.5×10{sup −18} and 5.2×10{sup −19} cm{sup 2} respectively. The studies have revealed the possibility of using diamond film for high dose radiation dosimetry with TL/OSL method.

  5. Investigation and dating of gypsum crystals from Sivrihisar region in Eskisehir by ESR and TL techniques

    International Nuclear Information System (INIS)

    2011-01-01

    Gypsum crystals taken from Sivrihisar-Eskisehir district were investigated and dated by Electron Spin Resonance (ESR) and Thermoluminescence (TL) techniques. The natural ESR spectra of gypsum samples had also the signals of Mn 2 + in addition to the signal at g=2.009. It was observed that the intensity of ESR signal at g=2.009 increased with gamma irradiation dose. This ESR signal (g=2.009) was used as a dating signal in dating of gypsum samples. The only one TL peak at about 278 degree Celsius was observed in TL glow curves of nonirradiated gypsum sample. In the case of irradiated sample, TL peak at 157 degree Celsius was observed in addition of TL peak at 278 degree Celsius. Gypsum samples were irradiated with a 6 0Co gamma source. The ESR spectra and TL glow curve of gypsum samples were recorded by X-band ESR spectrometer and Risφ TL/OSL reader, respectively. For samples, ESR/TL dose-response curves was constructed. Dose-response curves were fitted with an exponential saturation function. Based on this model, accumulated dose (AD) values for dating are determined. 2 38U, 2 32Th and 4 0K analysis was carried out for gypsum crystals and dolomite which enveloped these gypsum crystals. The internal dose rate was calculated from 2 38U, 2 32Th and 4 0K analysis results of gypsum sample. The external dose rate was calculated by using 2 38U, 2 32Th and 4 0K analysis results of dolomite and cosmic dose rate. Internal and external gamma dose-rate was used for dating calculations. Because of successive recrystallization of gypsum sample after formation, calculated age values of gypsum is smaller than expected formation age.

  6. 201Tl scintigraphic evaluation of tumor mass and viability of bone and soft-tissue tumors

    International Nuclear Information System (INIS)

    Tsuda, Takatoshi; Kubota, Masahiro; Yoshida, Satoru; Shibata, Masahito; Wakabayashi, Jun-ichi; Obata, Hiroyuki; Matsuyama, Toshikatsu; Usui, Masamichi; Ishii, Sei-ichi.

    1994-01-01

    To characterize 201 Tl uptake in patients with bone and soft-tissue tumor, we studied 49 patients with surgically proven tumors and one patient with a tumor diagnosed arteriographically. In 37 of our 50 patients, the tumor was evaluated with 201 Tl and arteriography. Moreover, in 14 of patients with pre-operative chemotherapy, pathologic changes were graded on the basis of percent tumor necrosis as defined histologically. The percent tumor necrosis histologically was compared with changes in the scintigraphic and conventional angiographic studies. Radiologic comparisons demonstrated a high degree of correlation with images of 201 Tl and both arterial and blood pool phase of 99m Tc-HMDP. Ninety-six percent of 28 malignant tumors had positive 201 Tl uptake. None of the patients showed any thallium accumulation in the soft tissues or skeleton adjacent to the lesion. Activity of 201 Tl was mainly dependent upon a tumor blood flow and a vascular density. In of 14 cases with the preoperative chemotherapeutic treatment, 201 Tl scintigraphic changes showed concordance with % tumor necrosis. Thallium-201 was superior to 99m Tc-HMDP in predicting tumor response to chemotherapy. Interestingly, delayed images of 99m Tc-HMDP of 5 responders with >90% tumor necrosis showed decreased uptake in the adjacent bone to the tumor mass lesions. It seems to be quite all right to consider that a major determinant of 201 Tl uptake is intratumoral angiogenecity, which is closely connected with tumor viability. Therefore, 201 Tl is a sensitive radiopharmaceutical for detection of vascular rich bone and soft-tissue tumors, and appears to be a simple and an accurate test for evaluating the response to specific therapeutic regimens of malignant bone and soft-tissue tumors. (author)

  7. Neutron scattering lengths of molten metals determined by gravity refractometry

    International Nuclear Information System (INIS)

    Reiner, G.; Waschkowski, W.; Koester, L.

    1990-01-01

    Very accurate values of the coherent neutron scattering lengths of the heavy elements Bi and Pb are important quantities for the investigation of the electric interactions of neutrons with atoms. We performed, therefore, a series of experiments to determine accurate scattering lengths by means of neutron gravity refractometry on liquid mirrors of molten metals. The possible perturbations of the necessary reflection measurements have been discussed in details. After taking into account the uncertainties and corrections associated with observable perturbations we obtained the following values for bound atoms: b(Bi)=8.532±0.002 fm, b(Pb)=9.405±0.003 fm, b(Tl)=8.776±0.005 fm, b(Sn)=6.225±0.002 fm and b(Ga)=7.288±0.002 fm. These data are corrected for the local field effect occuring in the reflection on liquids. The recently reported results for the neutron's electric polarizability and the neutron-electron scattering length are supported by the Bi- and Pb-scattering length of this work. (orig.)

  8. Neutron scattering lengths of molten metals determined by gravity refractometry

    Energy Technology Data Exchange (ETDEWEB)

    Reiner, G; Waschkowski, W; Koester, L [Technische Univ. Muenchen, Garching (Germany, F.R.). Fakultaet fuer Physik

    1990-10-01

    Very accurate values of the coherent neutron scattering lengths of the heavy elements Bi and Pb are important quantities for the investigation of the electric interactions of neutrons with atoms. We performed, therefore, a series of experiments to determine accurate scattering lengths by means of neutron gravity refractometry on liquid mirrors of molten metals. The possible perturbations of the necessary reflection measurements have been discussed in details. After taking into account the uncertainties and corrections associated with observable perturbations we obtained the following values for bound atoms: b(Bi)=8.532{plus minus}0.002 fm, b(Pb)=9.405{plus minus}0.003 fm, b(Tl)=8.776{plus minus}0.005 fm, b(Sn)=6.225{plus minus}0.002 fm and b(Ga)=7.288{plus minus}0.002 fm. These data are corrected for the local field effect occuring in the reflection on liquids. The recently reported results for the neutron's electric polarizability and the neutron-electron scattering length are supported by the Bi- and Pb-scattering length of this work. (orig.).

  9. Neutron scattering lengths of molten metals determined by gravity refractometry

    Energy Technology Data Exchange (ETDEWEB)

    Reiner, G.; Waschkowski, W.; Koester, L. (Technische Univ. Muenchen, Garching (Germany, F.R.). Fakultaet fuer Physik)

    1990-10-01

    Very accurate values of the coherent neutron scattering lengths of the heavy elements Bi and Pb are important quantities for the investigation of the electric interactions of neutrons with atoms. We performed, therefore, a series of experiments to determine accurate scattering lengths by means of neutron gravity refractometry on liquid mirrors of molten metals. The possible perturbations of the necessary reflection measurements have been discussed in details. After taking into account the uncertainties and corrections associated with observable perturbations we obtained the following values for bound atoms: b(Bi)=8.532{plus minus}0.002 fm, b(Pb)=9.405{plus minus}0.003 fm, b(Tl)=8.776{plus minus}0.005 fm, b(Sn)=6.225{plus minus}0.002 fm and b(Ga)=7.288{plus minus}0.002 fm. These data are corrected for the local field effect occuring in the reflection on liquids. The recently reported results for the neutron's electric polarizability and the neutron-electron scattering length are supported by the Bi- and Pb-scattering length of this work. (orig.).

  10. Centers responsible for the TL peaks of willemite mineral estimated by EPR analysis

    Energy Technology Data Exchange (ETDEWEB)

    Gundu Rao, T.K. [Instituto de Física, Universidade de São Paulo, Rua do Matão, Travessa R, 187, CEP 05508-090, São Paulo, SP (Brazil); Cano, Nilo F., E-mail: nilo.cano@unifesp.br [Departamento de Ciências do Mar, Universidade Federal de São Paulo, Rua Doutor Carvalho de Mendonça, 144, CEP 11070-102, Santos, SP (Brazil); Silva-Carrera, Betzabel N.; Ferreira, Reinaldo M. [Instituto de Física, Universidade de São Paulo, Rua do Matão, Travessa R, 187, CEP 05508-090, São Paulo, SP (Brazil); Javier-Ccallata, Henry S., E-mail: henrysjc@gmail.com [Escuela Profesional de Física, Facultad de Ciencias Naturales y Formales, Universidad Nacional de San Agustín (UNSA), Av. Independencia S/N, Arequipa (Peru); Watanabe, Shigueo, E-mail: watanabe@if.usp.br [Instituto de Física, Universidade de São Paulo, Rua do Matão, Travessa R, 187, CEP 05508-090, São Paulo, SP (Brazil)

    2016-09-15

    The mineral willemite (Zn{sub 2}SiO{sub 4}) exhibits five thermoluminescence (TL) peaks approximately at 160, 225, 260, 310 and 400 °C. Electron paramagnetic resonance (EPR) studies were carried out to study the defect centers induced in the mineral by gamma irradiation and also to identify the centers responsible for the TL process. Room temperature EPR spectrum of irradiated mineral is a superposition of at least four distinct centers. One of the centers (center I) with an isotropic g factor 2.0114 is attributable to an intrinsic O{sup −} type center and the center correlates with the TL peak at 160 °C. Center II exhibiting hyperfine lines is also tentatively assigned to an O{sup −} ion and is related to the low temperature TL peak at 160 °C. Center III is characterized by an axially symmetric g-tensor with principal values g{sub ||}=2.0451 and g{sub ⊥}=2.011 and is identified as an O{sub 2}{sup −} ion. This center appears to be related to 160, 225 and 260 °C TL peaks. Center IV with principal g-values g{sub ||}=2.0025 and g{sub ⊥}=2.0088 is attributed to an F{sup +}-type center (singly ionized oxygen vacancy) and is the likely recombination center for TL peaks between 160 and 310 °C.

  11. Emission properties of thermoluminescence from natural quartz - blue and red TL response to absorbed dose

    International Nuclear Information System (INIS)

    Hashimoto, T.; Yokosaka, K.; Habuki, H.

    1987-01-01

    The TL spectrometry of natural quartz exposed to a gamma radiation dose of 8.8 kGy proved that the red TL, mainly from volcanically originated quartz, has a broad emission band with a peak around 620 nm, while the blue TL from plutonically originated quartz also has a broad emission band giving a peak around 470 nm. These typical red or blue intrinsic colours were also confirmed on the thermoluminescence colour images (TLCI). Exceptionally, a pegmatite quartz changed its TLCI colour from red to blue when the absorbed dose was increased. By using colour filter assemblies, all these quartz samples were shown to emit mainly blue and red TLs, which have distinctly different TL responses to the absorbed dose; the blue invariably showed a supralinearity relation between 1 and 10 kGy dose. For the purpose of dating, the use of red TL, is preferable. The red TL component is related to the impurity Eu content in quartz minerals. (author)

  12. TL and LOE dosimetric evaluation of diamond films exposed to beta and ultraviolet radiation

    International Nuclear Information System (INIS)

    Preciado F, S.; Melendrez, R.; Chernov, V.; Barboza F, M.; Schreck, M.; Cruz Z, E.

    2005-01-01

    The diamond possesses a privileged position regarding other materials of great technological importance. Their applications go from the optics, microelectronics, metals industry, medicine and of course as dosemeter, in the registration and detection of ionizing and non ionizing radiation. In this work the results of TL/LOE obtained in two samples of diamond of 10 μm thickness grown by the chemical vapor deposition method (CVD) assisted by microwave plasma. The films were deposited in a silicon substrate (001) starting from a mixture of gases composed of CH 4 /H 2 and 750 ppm of molecular nitrogen as dopant. The samples were exposed to beta radiation (Sr 90 / Y 90 ) and ultraviolet, being stimulated later on thermal (TL) and optically (LOE) to evaluate their dosimetric properties. The sample without doping presented high response TL/LOE to the ultraviolet and beta radiation. The TL glow curve of the sample without doping showed two TL peaks with second order kinetics in the range of 520 to 550 K, besides a peak with first order kinetics of more intensity around 607 K. The TL efficiency of the non doped sample is bigger than the doped with nitrogen; however the LOE efficiency is similar in both samples. The results indicate that the CVD diamond possesses excellent perspectives for dosimetric applications, with special importance in radiotherapy due to it is biologically compatible with the human tissue. (Author)

  13. Conceptualizing and Communicating SoTL: A Framework for the Field

    Directory of Open Access Journals (Sweden)

    Janice Miller-Young

    2015-09-01

    Full Text Available The emerging field of SoTL is an inherently interdisciplinary endeavor which requires embracing a diverse range of research methods and disciplinary differences in world views. This diversity has caused a lack of coherence in its conceptualization and communication, which can be confusing for new scholars. Ongoing debates in the community concern the use of theory and methodology, as well as definitional questions of what constitutes SoTL and the nature of its purpose. This article offers a framework for conceptualizing the field which attempts to broadly delineate the available learning theories underlying and methodologies appropriate to studying teaching and learning, while intending to be hospitable to a broad range of diverse disciplines. Further, the framework illustrates the tacit links between learning theories and methodologies, serving as a guide to potential approaches to SoTL work. The framework is illustrated with example SoTL studies. It is hoped that the framework will help ground future SoTL investigations in appropriate theories and methodologies, and build interdisciplinary communication and understanding in the “trading zone” that is SoTL.

  14. Living with the altered self: a qualitative study of life after total laryngectomy.

    Science.gov (United States)

    Bickford, Jane; Coveney, John; Baker, Janet; Hersh, Deborah

    2013-06-01

    Total laryngectomy (TL), a life-preserving surgery, results in profound physical and communication changes for the individual. Physical and psychosocial adjustment to a TL is complex, and quality-of-life (QoL) measures have provided useful knowledge to assist clinical management. However, many tools were developed without considering the perspectives of people who have experienced TL. To improve understanding of the phenomena of living with TL, a qualitative study was conducted which explored the views and experiences of seven men and five women from a range of ages, geographical locations, and social situations who had undergone a TL. Data were collected through in-depth, semi-structured interviews, journals, and field notes, and analysed using a constructivist grounded theory approach and symbolic interactionism. The emergent concept was identifying with the altered self after TL as reflected in dynamic multi-level changes (physical, communication, and psycho-emotional) continuously interacting with intrinsic and extrinsic interpersonal factors including personal and socio-cultural constructs, e.g., age, gender, resilience, beliefs, and supports. This process affected the strategies these individuals used to negotiate their social experiences. The extent to which communication changes disrupted social roles affecting a person's sense of self appeared to relate to long-term adjustment.

  15. 201Tl myocardial SPECT and β-endorphin levels in patients with suspected silent ischemia

    International Nuclear Information System (INIS)

    Lind, P.; Binter, G.; Koeltringer, P.; Eber, O.; Eber, B.; Klein, W.; Brandt, D.

    1990-01-01

    Today silent myocardial ischemia (SMI) is a well-recognized phenomenon. Treadmill exercise according to the Bruce protocol, 201 Tl myocardial SPECT and coronary angiography were performed in a total of 106 patients with suspected SMI. In group I (high probability of ischemia; n=46), reversible defects detected by SPECT correlated well with significant stenoses and irreversible defects with subtotal stenoses or complete occlusions. SPECT sensitivity in the detection of ischemia was 91%, its specificity 96%. In group II (low probability of ischemia; n=60), SPECT sensitivity was as high as in group I (94%) but due to a high number of false-positive results (e.g. cardiomyopathy) specificity was only 75%. However, SPECT was superior to exercise ECG (sensitivity 70%; specificity 56%) in the detection of SMI. In addition, β-endorphin levels were determined in 180 healthy subjects, 37 patients with symptomatic CAD and in 34 patients with SMI before and during maximum exercise. Exercise values in patients with SMI were significantly higher than in healthy subjects or in patients with symptomatic CAD. (orig./MG) [de

  16. Adsorption kinetics of 201Tl and migration of 99mTc in natural soils

    International Nuclear Information System (INIS)

    Rodriguez N, C. E.; Monroy G, F.; Fernandez R, E.; Anguiano A, J.

    2012-10-01

    The safety is very important in facilities where radioactive wastes are stored. One of the necessary characteristics of the site where these wastes will be disposed is the soil permeability, since a waterproof terrain avoids the diffusion and radionuclide transport in the leakages case. The objective of this work is to study the adsorption kinetics of 201 Tl and the migration of 99m Tc in natural soil samples. The adsorption kinetics was determined starting from the obtaining of the retention coefficient of the thallium (static method) at different contact times. The technetium diffusion was studied by means of the dynamic method with different soil particles sizes. The results showed that the thallium is totally adsorbed starting from 20 h of contact among this and the mean. On the other hand, the technetium is very mobile in the soil, since it was possible to extract the majority of the tracer with little solvent. Also, it was found that for each soil gram the double water will be needed to leach the technetium almost in its entirety. Moreover, influence exists of the particle size in the migration velocity from the radiotracer to the most mobile being in major sizes than 2 mm that in minor size. (Author)

  17. PUFA Status and Methylmercury Exposure Are Not Associated with Leukocyte Telomere Length in Mothers or Their Children in the Seychelles Child Development Study.

    Science.gov (United States)

    Yeates, Alison J; Thurston, Sally W; Li, Huiqi; Mulhern, Maria S; McSorley, Emeir M; Watson, Gene E; Shamlaye, Conrad F; Strain, J J; Myers, Gary J; Davidson, Philip W; van Wijngaarden, Edwin; Broberg, Karin

    2017-11-01

    Background: Leukocyte telomere length (TL) is associated with age-related diseases and early mortality, but there is a lack of data on the determinants of TL in early life. Evidence suggests that dietary intake of marine n-3 (ω-3) polyunsaturated fatty acids (PUFAs) is protective of telomere attrition, yet the effect of methylmercury exposure, also found in fish, on TL is unknown. Objective: The aim of this study was to investigate the associations between prenatal PUFA status, methylmercury exposure, and TL in mothers and children in the SCDS (Seychelles Child Development Study), for whom fish consumption is high. Methods: Blood samples collected from 229 mothers (at 28 wk gestation and delivery) and children (at 5 y of age) in the SCDS first nutrition cohort were analyzed for PUFA concentrations. Prenatal mercury was measured in maternal hair collected at delivery. Postnatal mercury was also measured in children's hair samples with the use of a cumulative metric derived from values obtained at 3-5 y of age. Relative TL was measured in blood obtained from mothers at delivery, in cord blood, and in children at 5 y of age by quantitative polymerase chain reaction. Linear regression models were used to investigate the associations between PUFA status, methylmercury exposure, and TL. Results: Neither prenatal PUFA status or methylmercury exposure was associated with TL of the mother or child or with TL attrition rate. However, a higher prenatal n-6:n-3 PUFA ratio was significantly associated with longer TLs in the mothers (β = 0.001, P = 0.048). Child PUFA status and methylmercury exposure were not associated with child TL. However, higher family Hollingshead socioeconomic status (SES) scores at 9 mo of age were significantly associated with longer TLs in cord blood (β = 0.005, P = 0.03). Conclusions: We found no evidence that PUFA status or methylmercury exposure are determinants of TL in either the mother or child. However, our results support the hypothesis that

  18. The X-ray response of TlBr

    International Nuclear Information System (INIS)

    Owens, Alan; Bavdaz, M.; Brammertz, G.; Gostilo, V.; Graafsma, H.; Kozorezov, A.; Krumrey, M.; Lisjutin, I.; Peacock, A.; Puig, A.; Sipila, H.; Zatoloka, S.

    2003-01-01

    We present the results of a series of X-ray measurements on several prototype TlBr detectors. The devices were fabricated from mono-crystalline material and were typically of size 2.7x2.7x0.8 mm 3 . The material is extremely pure, having impurity concentrations -4 and 1x10 -5 cm 2 V -1 , respectively, which are about an order of magnitude higher than previously reported values. Three detectors were fabricated and extensively tested over the energy range 2.3-100 keV at three synchrotron radiation facilities: the Physikalisch-Technische Bundesanstalt (PTB) laboratory at the Berliner Elektronenspeicherring fuer Synchrotronstrahlung (BESSY II), the European Synchrotron Radiation Research Facility (ESRF) and the Hamburger Synchrotron-strahlungslabor (HASYLAB) radiation facility. Room temperature energy resolutions under full-area illumination of 1.8 and 3.3 keV FWHM have been achieved at 5.9 and 59.95 keV, respectively. At reduced detector temperatures of -30 deg. C, these fall to 800 eV and 2.6 keV FWHM, respectively. Under monochromatic pencil beam illumination, the measured energy resolutions at 6 and 60 keV were 664 eV and ∼3 keV FWHM at the same temperature. For energies 2 , 12 keV mono-energetic X-ray beam, raster scanned over the forward active area. Whilst two detectors were spatially uniform to a level commensurate with statistics, the third was not. In all cases, evidence was found for charge collection problems caused by field fringing

  19. Working conditions analysis according T.L. personal dosimetry results

    International Nuclear Information System (INIS)

    Marinkovic, O.; Jovanovic, S.

    2006-01-01

    Laboratory for personal dosimetry in the Institute of Occupational and Radiological Health, Belgrade, used TLD more than twenty years. Before that, film dosimetry was main method in external monitoring. T.L. dosimetry was started with Reader Toledo 654 and crystals Mg B 4 O 7 . Finally, from 1992 laboratory has Harshaw TLD Reader Model 6600. Dosimeters are crystals LiF type 100, card packed, worn in standard filtrated holders. Personal dosimetry data are keeping 30 years for each worker according to regulations. The data from 1990 are in electronic form. Long experience enables conclusion that new technique means more advantages in practice. Recommendation from this laboratory practice refers to TLD read-out cycle. The longest period should be one month. LiF is recommended crystal. Glow curve deconvolution gives information about chronological irradiation. It is very important to conclude was dosimetry irradiated by 'one-shot' or continuously. Preparing calibration for determination the time since accident laboratory has to define adequate dose calibration methodology including low temperature peaks. Possibility to follow working conditions analyzing TLD glow curve is much more important than low decrease of dose severity. Time depend analyze is not possible if TLD would be read-out more than (approximately) six weeks after irradiation. If ionizing sources produce such low dose and has negligible probability of accidental exposure (according nowadays regulation read-out frequency could be once in three month), the recommendation is not to use external personal monitoring. Reading personal dosimeters once in three months deemed not useful. Complete and successful personal dosimetry dictates using system that enables glow curve shape representation to be sure that signal is ionizing irradiation result or not. Time depend analyze imparts information about protection permanence. In special circumstance, it is possible to estimate the time of exposure. This is extremely

  20. TL dosimetry for quality control of CR mammography imaging systems

    Science.gov (United States)

    Gaona, E.; Nieto, J. A.; Góngora, J. A. I. D.; Arreola, M.; Enríquez, J. G. F.

    The aim of this work is to estimate the average glandular dose with thermoluminescent (TL) dosimetry and comparison with quality imaging in computed radiography (CR) mammography. For a measuring dose, the Food and Drug Administration (FDA) and the American College of Radiology (ACR) use a phantom, so that dose and image quality are assessed with the same test object. The mammography is a radiological image to visualize early biological manifestations of breast cancer. Digital systems have two types of image-capturing devices, full field digital mammography (FFDM) and CR mammography. In Mexico, there are several CR mammography systems in clinical use, but only one system has been approved for use by the FDA. Mammography CR uses a photostimulable phosphor detector (PSP) system. Most CR plates are made of 85% BaFBr and 15% BaFI doped with europium (Eu) commonly called barium flourohalideE We carry out an exploratory survey of six CR mammography units from three different manufacturers and six dedicated X-ray mammography units with fully automatic exposure. The results show three CR mammography units (50%) have a dose greater than 3.0 mGy without demonstrating improved image quality. The differences between doses averages from TLD system and dosimeter with ionization chamber are less than 10%. TLD system is a good option for average glandular dose measurement for X-rays with a HVL (0.35-0.38 mmAl) and kVp (24-26) used in quality control procedures with ACR Mammography Accreditation Phantom.

  1. Photoinduced Optical Properties Of Tl1−xIn1−xSixSe2 Single Crystals

    Directory of Open Access Journals (Sweden)

    Myronchuk G.L.

    2015-06-01

    Full Text Available The influence of temperature on electroconductivity and photoinduced changes of the absorption at 0.15 eV under influence of the second harmonic generation of CO2 laser for the two type of single crystals were investigated. The single crystals Tl1−xIn1−xSixSe2 (x=0.1 and 0.2 have been grown by the two-zone Bridgaman-Stockbarger method. The temperature studies of electroconductivity were done in cryostat with thermoregulation in the temperature 77 - 300 K, with stabilization ±0.1 K. Photoinduced treatment of the investigated single crystals were performed using the 180 ns pulses second harmonic generation of the CO2 laser operating at 5.3 μm. Experimental studies have shown that for the Tl1−xIn1−xSixSe2 single crystals with decreasing temperature from 300 up to 240 K and from 315 up to 270 K the conductivity is realized by thermally excited impurities with activation energies equal to about 0.24 eV and 0.22 eV for x= 0.1 and 0.2, respectively. Photoinduced absorption achieves its maximum at a power density below 100 mJ/cm2. Has been shown that the samples with x=0.2 demonstrated higher changes of the photoinduced absorption with respect to the x=0.1. With further decreasing temperature is observed monotonic decrease in the activation energy of conductivity. The origin of these effects is caused by the excitations of both the electronic as well as phonon subsystem. At some power densities the anharmonic excitations become dominant and as a consequence the photoinduced absorption dependence is saturated what were observed. Additionally, we were evaluated at given temperature the average jump length of R for localized states near Fermi level.

  2. The length-weight and length-length relationships of bluefish, Pomatomus saltatrix (Linnaeus, 1766) from Samsun, middle Black Sea region

    OpenAIRE

    Özpiçak, Melek; Saygın, Semra; Polat, Nazmi

    2017-01-01

    In this study, length-weight relationship (LWR) and length-length relationship (LLR) of bluefish,Pomatomus saltatrix were determined. A total of 125 specimens were sampled from Samsun, themiddle Black Sea in 2014 fishing season. Bluefish specimens were monthly collected fromcommercial fishing boats from October to December 2014. All captured individuals (N=125) weremeasured to the nearest 0.1 cm for total, fork and standard lengths. The weight of each fish (W)was recorded to the nearest 0.01 ...

  3. Detection of irradiated foods by the thermoluminescence. Relationships between the temperature ranges of integrating TL glow curves and TL glow ratios

    International Nuclear Information System (INIS)

    Sekiguchi, Masayuki; Yamazaki, Masao; Goto, Michiko; Todoriki, Setsuko; Hagiwara, Shoji

    2007-01-01

    Our study demonstrated that the effects of the several temperature ranges for integrating TL glow intensity on the TL glow ratios by using spice-set purchased at a Turkish air port. The spice set had no labeling of irradiation feeds, but nine of 12 spices were judged as irradiated food in this study. Those temperature ranges were defined by evaluating the glow curves of irradiated TLD-100 chip (167-230degC), TLD-100 disc (177-238degC) and Dolomite element (145-258degC). Those are relatively stable and the difference of typical glow peak temperatures of TLD-100 disc in two institutes was less than 2%. On the other hand, those of TLD-100 tip was shift to higher temperature side at about 4degC because of declining of thermal conductance. The temperature ranges defined by TLD-100 were showed that discriminate more clearly between irradiated and nonirradiated spices compared with the full temperature range of TL measurement (70-400degC). With the exception of low glow intensity, background measurement for estimating net glow intensity was not necessary because TL glow ratio was hardly influenced whether the background measured or not. (author)

  4. Real-time in-situ monitoring of the topotactic transformation of TlCu3Se2 into TlCu2Se2

    International Nuclear Information System (INIS)

    Ångström, J.; Sahlberg, M.; Berger, R.

    2015-01-01

    Highlights: • Topotactic transition from TlCu 3 Se 2 to TlCu 2 Se 2 followed in situ. • Synchrotron radiation X-ray powder diffraction enabled short scans. • Relative abundance of phases refined from powder data. • Opens up for studying similar systems in the same manner. - Abstract: The solid state transformation of monoclinic TlCu 3 Se 2 into tetragonal TlCu 2 Se 2 by oxidative copper leaching in concentrated ammonia solution has been studied in situ by the use of synchrotron radiation. The diffraction patterns of parent and daughter phase are both sharp, indicating a strong topotactic relationship between them that effectuates a rapid change by “chimie douce” performed at +19 °C. The transformation rate is strongly connected to the access of oxygen from the surrounding air. The transformation was followed in a real-time mode, being almost complete after 2.5 h with 1 h incubation due to low oxygen content, as shown from refining the diffraction patterns by Rietveld profile technique

  5. Longitudinal changes in telomere length and associated genetic parameters in dairy cattle analysed using random regression models.

    Directory of Open Access Journals (Sweden)

    Luise A Seeker

    Full Text Available Telomeres cap the ends of linear chromosomes and shorten with age in many organisms. In humans short telomeres have been linked to morbidity and mortality. With the accumulation of longitudinal datasets the focus shifts from investigating telomere length (TL to exploring TL change within individuals over time. Some studies indicate that the speed of telomere attrition is predictive of future disease. The objectives of the present study were to 1 characterize the change in bovine relative leukocyte TL (RLTL across the lifetime in Holstein Friesian dairy cattle, 2 estimate genetic parameters of RLTL over time and 3 investigate the association of differences in individual RLTL profiles with productive lifespan. RLTL measurements were analysed using Legendre polynomials in a random regression model to describe TL profiles and genetic variance over age. The analyses were based on 1,328 repeated RLTL measurements of 308 female Holstein Friesian dairy cattle. A quadratic Legendre polynomial was fitted to the fixed effect of age in months and to the random effect of the animal identity. Changes in RLTL, heritability and within-trait genetic correlation along the age trajectory were calculated and illustrated. At a population level, the relationship between RLTL and age was described by a positive quadratic function. Individuals varied significantly regarding the direction and amount of RLTL change over life. The heritability of RLTL ranged from 0.36 to 0.47 (SE = 0.05-0.08 and remained statistically unchanged over time. The genetic correlation of RLTL at birth with measurements later in life decreased with the time interval between samplings from near unity to 0.69, indicating that TL later in life might be regulated by different genes than TL early in life. Even though animals differed in their RLTL profiles significantly, those differences were not correlated with productive lifespan (p = 0.954.

  6. Telomere length and advanced diffusion MRI as biomarkers for repetitive mild traumatic brain injury in adolescent rats

    Directory of Open Access Journals (Sweden)

    David K. Wright

    Full Text Available Mild traumatic brain injuries (mTBI are of worldwide concern in adolescents of both sexes, and repeated mTBI (RmTBI may have serious long-term neurological consequences. As such, the study of RmTBI and discovery of objective biomarkers that can help guide medical decisions is an important undertaking. Diffusion-weighted MRI (DWI, which provides markers of axonal injury, and telomere length (TL are two clinically relevant biomarkers that have been implicated in a number of neurological conditions, and may also be affected by RmTBI. Therefore, this study utilized the lateral impact injury model of RmTBI to investigate changes in diffusion MRI and TL, and how these changes relate to each other. Adolescent male and female rats received either three mTBIs or three sham injuries. The first injury was given on postnatal day 30 (P30, with the repeated injuries separated by four days each. Seven days after the final injury, a sample of ear tissue was collected for TL analysis. Rats were then euthanized and whole brains were collected and fixated for MRI analyses that included diffusion and high-resolution structural sequences. Compared to the sham-injured group, RmTBI rats had significantly shorter TL at seven days post-injury. Analysis of advanced DWI measures found that RmTBI rats had abnormalities in the corpus callosum and cortex at seven days post-injury. Notably, many of the DWI changes were correlated with TL. These findings demonstrate that TL and DWI measurements are changed by RmTBI and may represent clinically applicable biomarkers for this. Keywords: Biomarker, Concussion, Track weighted imaging, Animal model, Diffusion tensor imaging, MRI

  7. Neutron scattering lengths of 3He

    International Nuclear Information System (INIS)

    Alfimenkov, V.P.; Akopian, G.G.; Wierzbicki, J.; Govorov, A.M.; Pikelner, L.B.; Sharapov, E.I.

    1976-01-01

    The total neutron scattering cross-section of 3 He has been measured in the neutron energy range from 20 meV to 2 eV. Together with the known value of coherent scattering amplitude it leads to the two sts of n 3 He scattering lengths

  8. Factors affecting accuracy of ventricular volume and ejection fraction measured by gated Tl-201 myocardial perfusion single photon emission computed tomography

    International Nuclear Information System (INIS)

    Pai, Moon Sun; Yang, You Jung; Im, Ki Chun; Hong, Il Ki; Yun, Sung Cheol; Kang, Duk Hyun; Song, Jae Kwan; Moon, Dae Hyuk

    2005-01-01

    Systemic errors in the gated single photon emission computed tomography (SPECT) measurement of left ventricular (LV) end-diastolic volume (EDV), end-systolic volume (ESV) and ejection fraction (EF) may occur. We evaluated whether patient-related factors affected the accuracy of EDV, ESV, and EF measured by electrocardiogram-gated Tl-201 SPECT. A total of 518 patients without perfusion defects on Tl-201 SPECT or coronary artery disease were studied. EDV, ESV, and EF were measured from echocardiography and adenosine stress/redistribution gated Tl-201 SPECT using commercially available software packages (QGS and 4D-MSPECT). We identified factors affecting the accuracy of gated SPECT via multiple linear regression analysis of the differences between echocardiography and gated SPECT. Gated SPECT analyzed with QGS underestimated EDV and ESV, and overestimated EF, but 4D-MSPECT overestimated all those values (p<0.001). Independent variables that increased the difference in EDV between echocardiography and gated SPECT were decreasing LV end-diastolic wall thickness, decreasing body surface area, female sex and increasing EDV (p< 0.001). Those for ESV were decreasing LV end-systolic wall thickness, female sex, and decreasing ESV (p<0.001). Increasing end-systolic wall thickness, male sex and decreasing age were independent determinants associated with an increased difference in EF (p< 0.001). Adenosine stress SPECT showed significantly higher EDV and ESV values and a lower EF than did redistribution SPECT (p< 0.001). In determination of EF, QGS demonstrated a smaller bias than did 4D-MSPECT. However, in men with LV hypertrophy, 4D-MSPECT was superior to QGS. Systemic error by gated Tl-201 SPECT is determined by individual patient-characteristics

  9. SCOPE-mTL: A non-invasive tool for identifying and lateralizing mesial temporal lobe seizures prior to scalp EEG ictal onset.

    Science.gov (United States)

    Lam, Alice D; Maus, Douglas; Zafar, Sahar F; Cole, Andrew J; Cash, Sydney S

    2017-09-01

    In mesial temporal lobe (mTL) epilepsy, seizure onset can precede the appearance of a scalp EEG ictal pattern by many seconds. The ability to identify this early, occult mTL seizure activity could improve lateralization and localization of mTL seizures on scalp EEG. Using scalp EEG spectral features and machine learning approaches on a dataset of combined scalp EEG and foramen ovale electrode recordings in patients with mTL epilepsy, we developed an algorithm, SCOPE-mTL, to detect and lateralize early, occult mTL seizure activity, prior to the appearance of a scalp EEG ictal pattern. Using SCOPE-mTL, 73% of seizures with occult mTL onset were identified as such, and no seizures that lacked an occult mTL onset were identified as having one. Predicted mTL seizure onset times were highly correlated with actual mTL seizure onset times (r=0.69). 50% of seizures with early mTL onset were lateralizable prior to scalp ictal onset, with 94% accuracy. SCOPE-mTL can identify and lateralize mTL seizures prior to scalp EEG ictal onset, with high sensitivity, specificity, and accuracy. Quantitative analysis of scalp EEG can provide important information about mTL seizures, even in the absence of a visible scalp EEG ictal correlate. Copyright © 2017 International Federation of Clinical Neurophysiology. Published by Elsevier B.V. All rights reserved.

  10. Novel interplay between high-Tc superconductivity and antiferromagnetism in Tl-Based Six-CuO2-layered cuprates. 205Tl- and 63Cu-NMR probes

    International Nuclear Information System (INIS)

    Mukuda, Hidekazu; Shiki, Nozomu; Kimoto, Naoki; Yashima, Mitsuharu; Kitaoka, Yoshio; Tokiwa, Kazuyasu; Iyo, Akira

    2016-01-01

    We report 63 Cu- and 205 Tl-NMR studies on six-layered (n = 6) high-T c superconducting (SC) cuprate TlBa 2 Ca 5 Cu 6 O 14+δ (Tl1256) with T c ∼ 100 K, which reveal that antiferromagnetic (AFM) order takes place below T N ∼ 170 K. In this compound, four underdoped inner CuO 2 planes [n(IP) = 4] sandwiched by two outer planes (OPs) are responsible for the onset of AFM order, whereas the nearly optimally-doped OPs responsible for the onset of bulk SC. It is pointed out that an increase in the out-of-plane magnetic interaction within an intra-unit-cell causes T N ∼ 45 K for Tl1245 with n(IP) = 3 to increase to ∼170 K for Tl1256 with n(IP) = 4. It is remarkable that the marked increase in T N and the AFM moments for the IPs does not bring about any reduction in T c , since T c ∼ 100 K is maintained for both compounds with nearly optimally doped OP. We highlight the fact that the SC order for n ≥ 5 is mostly dominated by the long-range in-plane SC correlation even in the multilayered structure, which is insensitive to the magnitude of T N and the AFM moments at the IPs or the AFM interaction among the IPs. These results demonstrate a novel interplay between the SC and AFM orders when the charge imbalance between the IPs and OP is significantly large. (author)

  11. Two anhydrous zeolite X crystal structures, Pd sub 1 sub 8 Tl sub 5 sub 6 Si sub 1 sub 0 sub 0 Al sub 9 sub 2 O sub 3 sub 8 sub 4 and Pd sub 2 sub 1 Tl sub 5 sub 0 Si sub 1 sub 0 sub 0 Al sub 9 sub 2 O sub 3 sub 8 sub 4

    CERN Document Server

    Yoon, B Y; Lee, S H; Kim, Y

    2001-01-01

    The crystal structures of fully dehydrated Pd sup 2 sup + - and Tl sup + -exchanged zeolite X, Pd sub 1 sub 8 Tl sub 5 sub 6 Si sub 1 sub 0 sub 0 Al sub 9 sub 2 O sub 3 sub 8 sub 4 (Pd sub 1 sub 8 Tl sub 5 sub 6 X, a = 24.935(4) A) and Pd sub 2 sub 1 Tl sub 5 sub 0 Si sub 1 sub 0 sub 0 Al sub 9 sub 2 O sub 3 sub 8 sub 4 (Pd sub 2 sub 1 Tl sub 5 sub 0 -X, a = 24.914(4) A), have been determined by single-crystal X-ray diffraction methods in the cubic space group Fd3 at 21(1) .deg. C. The crystals were prepared using an exchange solution that had a Pd(NH sub 3) sub 4 Cl sub 2 : TINO sub 3 mole ratio of 50 : 1 and 200 : 1, respectively, with a total concentration of 0.05 M for 4 days. After dehydration at 360 .deg. C and 2 x 10 sup - sup 6 Torr in flowing oxygen for 2 days, the crystals were evacuated at 21(1) .deg. C for 2 hours. They were refined to the final error indices R sub 1 = 0.045 and R sub 2 = 0.038 with 344 reflections for Pd sub 1 sub 8 Tl sub 5 sub 6 -X, and R sub 1 = 0.043 and R sub 2 = 0.045 with ...

  12. The comparison between the length of vertical dimension of occlusion and the length of thumb on undergraduate Mongoloid students

    Directory of Open Access Journals (Sweden)

    Goh Li Teng

    2011-03-01

    Full Text Available The Thumb Rule of Leonardo da Vinci states that many proportions of the face show relationship with the length of thumb which is measured from the proximal tip of the proximal phalanx to the distal tip of the distal phalanx. Previous studies have shown that the length of the vertical dimension of occlusion (VDO is similar to the length of thumb of the Caucasoid race. The purpose of this study is to determine whether the length of VDO have correlations with the length of thumb among those of the Mongoloid race. This study took a survey method with the analytical cross-sectional approach. A total of 80 students of Faculty of Dentistry who have fulfilled all population criteria were randomly chosen to measure the length of VDO and the length of the thumb. Results analyzed with Student's t-test statistic revealed that there was a significant difference between males and females in the length of VDO and the length of the thumb, however, there was no significant difference between the length of VDO and the length of the thumb. There were very strong correlations (P<0.05 between the length of VDO and the length of the thumb. As a conclusion, the length of thumb can be suggested as an objective method to determine the length of VDO in this population.

  13. TL and OSL studies of carbon doped magnesium aluminate (MgAl2O4:C)

    Science.gov (United States)

    Raj, Sanu S.; Mishra, D. R.; Soni, Anuj; Grover, V.; Polymeris, G. S.; Muthe, K. P.; Jha, S. K.; Tyagi, A. K.

    2016-10-01

    The MgAl2O4:C has been synthesized by using two different methods by electron gun and vacuum assisted melting of MgAl2O4 in presence of graphite. The MgAl2O4:C phosphor thus developed by these two different methods have similar types of the TL/OSL defects with multiple overlapping TL glow peaks from 100 °C to 400 °C. The Computerized Curve De-convolution Analysis (CCDA) has been used to measure TL parameters such as thermal trap depth, frequency factor and order of kinetic associated with charge transfer process in TL phenomenon. The investigated TL/OSL results show that these two methods of incorporating carbon in MgAl2O4 have generated closely resemble the defects of similar types in MgAl2O4:C lattice. However, the MgAl2O4:C synthesized by electron gun shows relatively larger concentration of the TL/OSL defects as compared to MgAl2O4:C synthesized using vacuum assisted melting method. The photo-ionization cross-section (PIC) associated with fastest OSL component of MgAl2O4: C is found to be ∼ 0.5 times than that of fastest OSL component of commercially available dosimetric grade α-Al2O3:C. The MgAl2O4:C thus developed shows good dynamic OSL dose linearity from few mGy to 1 Gy. This work reveals that MgAl2O4:C could be developed as potential tissue equivalent OSL / TL material.

  14. TL and OSL dosimetric properties of Opal gemstone for gamma radiation dosimetry

    International Nuclear Information System (INIS)

    Antonio, Patrícia L.; Gronchi, Claudia C.; Oliveira, Raquel A.P.; Khoury, Helen J.; Caldas, Linda V.E.

    2016-01-01

    In this work, the response of the natural material Opal was studied in relation to its thermoluminescence (TL) and optically stimulated luminescence (OSL), after exposure to the gamma radiation of a "6"0Co source. The structure of the powdered Opal was verified using the X-ray diffraction, scanning electronic microscopy and energy-dispersive X-ray spectroscopy techniques. The material, in its stone form, was turned into powder and mixed to Teflon (also in powder) in three different concentrations, and then pellets were manufactured. The aim of this work was to evaluate the response of these pellets in high-doses of gamma radiation beams, and to observe their possible application as dosimeters, using the TL and OSL techniques. The dosimetric properties of the samples were analyzed by means of different tests, as: TL emission curves and OSL signal decay curves, reproducibility of TL and OSL response, minimum detectable dose, TL and OSL dose–response curves (5 Gy–10 kGy), and fading. The results obtained in this work, for the TL and OSL phenomena, demonstrated that the pellets of Opal + Teflon present an adequate performance e possibility of use as dosimeters in beams of high-dose gamma radiation. - Highlights: • The XRD, SEM and EDX techniques were used to investigate powdered Opal. • Pellets of three different concentrations of Opal and Teflon were studied. • The dosimetric properties of the Opal + Teflon pellets were verified. • TL and OSL techniques were used to analyze the characteristics of the pellets. • Pellets of concentration of 2:1 (Opal:Teflon) presented the most adequate results.

  15. Development of NaI(Tl) scintillating films for imaging soft x-rays

    International Nuclear Information System (INIS)

    Shepherd, J.A.

    1993-01-01

    Thin film NaI(Tl) scintillators, of areas of up to 130 cm 2 , have been fabricated and characterized for use on soft x-ray imaging photomultiplier tubes. Relevant parameters of photon-counting imaging detectors are defined and used to predict the performance of several materials, including CsI(Na), CsI(Tl), CaF 2 (Eu), Lu 2 (SiO 4 )O:Ce, and NaI(Tl), as thin film scintillators on fiber optic substrates. Also, x-ray imaging methodologies are compared. The NaI(Tl) films were vapor-deposited onto quartz and fiber optic substrates using a powder flash deposition technique. When compared to single crystal NaI(Tl), the films were found to have equally high light yield but lower energy resolution. Light yield optimization was studied in detail including the effects of substrate temperature, activator concentration in the evaporant, and boat temperature. Spatial resolution as well as parallax errors are discussed and measured for film thicknesses up to 61 μm. A technique is described that can substantially increase the light collection of high index films on fiber optic disks. The light collection was improved by 20% by coating the disk with potassium silicate before the NaI(Tl) deposition. Large area films, up to 130 cm 2 , had a spatial uniformity of response within ±1.5% for count rate and ±3.5% for light yield, and their spatial resolution exceeded 16.6 lp mm -1 when deposited onto fiber optic substrates. The 8-keV x-ray detection efficiency of the microchannel plate imaging photomultiplier tube coupled to a NaI(Tl) film scintillator is predicted to be 88%. Other uses for the films are also described

  16. Effects of ischemic-like insult on myocardial 201Tl accumulation

    International Nuclear Information System (INIS)

    Goldhaber, S.Z.; Newell, J.B.; Alpert, N.M.; Andrews, E.; Pohost, G.M.; Ingwall, J.S.

    1983-01-01

    Despite extensive clinical use of thallium-201 ( 201 Tl) for myocardial imaging, the effect of ischemia on myocardial accumulation and release of 201 Tl independent of flow has not been fully defined. Therefore, myocardial accumulation of 201 Tl in response to ischemic-like myocardial injury was assessed in vitro using the cultured fetal mouse heart preparation. Cultured fetal mouse hearts (n . 311) were subjected to injury simulating ischemia by deprivation of oxygen and oxidizable substrates for periods ranging from 15 minutes to 10 hours. The extent of irreversible injury was determined by the percentage of lactic dehydrogenase (LDH) lost from the hearts to the culture medium during recovery from injury. Injury was essentially reversible at 1 hour of insult. The fraction of 201 Tl content in injured compared with control hearts was not significantly lower after 1 hour of insult. By 3 hours of insult, irreversible injury as assessed by loss of LDH was detectable and the extent of injury increased progressively through 10 hours. During the 3-10-hour period of irreversible injury, 201 Tl accumulation within injured hearts compared with controls was related in a monotonically decreasing fashion to the loss of LDH as described by a mathematical kinetic model that fit the observations closely (R2 greater than 0.99). These results indicate that in this organ culture preparation, in which there is effectively an unlimited reservoir of 201 Tl and no confounding effects of perfusion, the time-dependent 201 Tl accumulation is determined by the extent of irreversible injury

  17. Structure and scintillation properties of CsI(Tl) films on Si single crystal substrates

    Energy Technology Data Exchange (ETDEWEB)

    Guo, Lina [State Key Laboratory of Electronic Thin Films and Integrated Devices, School of Optoelectronic Information, University of Electronic Science and Technology of China, Chengdu 610054 (China); Liu, Shuang, E-mail: shuangliu@uestc.edu.cn [State Key Laboratory of Electronic Thin Films and Integrated Devices, School of Optoelectronic Information, University of Electronic Science and Technology of China, Chengdu 610054 (China); Chen, Dejun; Zhang, Shangjian; Liu, Yong; Zhong, Zhiyong [State Key Laboratory of Electronic Thin Films and Integrated Devices, School of Optoelectronic Information, University of Electronic Science and Technology of China, Chengdu 610054 (China); Falco, Charles M. [University of Arizona, College of Optical Sciences, AZ 85721 (United States)

    2016-10-30

    Highlights: • We obtained the desired micro-columnar structure of CsI(Tl) films on the orienting Si substrates. • We improved the micro-columnar structure of CsI(Tl) films under the relatively large deposition rate through using the substrate with a pre-deposited CsI nanolayer. • We modeled the interface structures between the CsI(Tl) films with (200) and (310) orientation and Si(111) substrates to explain the preferred orientation of film under the influence of the orienting substrate significantly. • We gained a new spectrum of the CsI(Tl) films peaked at 740 nm wavelength. - Abstract: CsI(Tl) scintillation films fabricated on glass substrates are widely applied for X-ray imaging because their ability to grow in micro-columnar structure and proper emission wavelength matching CCD cameras. But the coupling process between the CsI(Tl) films and Si-based photo detector would cause coupling loss. In this work, CsI(Tl) films were deposited on the orienting Si substrates and the Si substrates covered by the pre-deposited CsI nanolayers. Structure and scintillation properties of films were examined by using scanning electron microscopy, X-ray diffraction, photoluminescence and radioluminescent spectrum. The films deposited on the orienting Si substrates show the micro-columnar morphology with perfect single crystalline structure and the photoluminescence spectra with bimodal distribution. The performances of the films prepared on the pre-deposited CsI nanolayer, containing micro-columns structure and the light yield are improved.

  18. Structure and scintillation properties of CsI(Tl) films on Si single crystal substrates

    International Nuclear Information System (INIS)

    Guo, Lina; Liu, Shuang; Chen, Dejun; Zhang, Shangjian; Liu, Yong; Zhong, Zhiyong; Falco, Charles M.

    2016-01-01

    Highlights: • We obtained the desired micro-columnar structure of CsI(Tl) films on the orienting Si substrates. • We improved the micro-columnar structure of CsI(Tl) films under the relatively large deposition rate through using the substrate with a pre-deposited CsI nanolayer. • We modeled the interface structures between the CsI(Tl) films with (200) and (310) orientation and Si(111) substrates to explain the preferred orientation of film under the influence of the orienting substrate significantly. • We gained a new spectrum of the CsI(Tl) films peaked at 740 nm wavelength. - Abstract: CsI(Tl) scintillation films fabricated on glass substrates are widely applied for X-ray imaging because their ability to grow in micro-columnar structure and proper emission wavelength matching CCD cameras. But the coupling process between the CsI(Tl) films and Si-based photo detector would cause coupling loss. In this work, CsI(Tl) films were deposited on the orienting Si substrates and the Si substrates covered by the pre-deposited CsI nanolayers. Structure and scintillation properties of films were examined by using scanning electron microscopy, X-ray diffraction, photoluminescence and radioluminescent spectrum. The films deposited on the orienting Si substrates show the micro-columnar morphology with perfect single crystalline structure and the photoluminescence spectra with bimodal distribution. The performances of the films prepared on the pre-deposited CsI nanolayer, containing micro-columns structure and the light yield are improved.

  19. Short telomere length is associated with NOTCH1/SF3B1/TP53 aberrations and poor outcome in newly diagnosed chronic lymphocytic leukemia patients

    DEFF Research Database (Denmark)

    Mansouri, Larry; Grabowski, Pawel; Degerman, Sofie

    2013-01-01

    Most previous studies on telomere length (TL) in chronic lymphocytic leukemia (CLL) are based on referral cohorts including a high proportion of aggressive cases. Here, the impact of TL was analyzed in a population-based cohort of newly diagnosed CLL (n = 265) and in relation to other prognostic ...... markers. Short telomeres were particularly associated with high-risk genetic markers, such as NOTCH1, SF3B1, or TP53 aberrations, and predicted a short time to treatment (TTT) and overall survival (OS) (both P...

  20. The effects of chemical and radioactive properties of Tl-201 on human erythrocyte glucose 6-phosphate dehydrogenase activity

    International Nuclear Information System (INIS)

    Sahin, Ali; Senturk, Murat; Ciftci, Mehmet; Varoglu, Erhan; Kufrevioglu, Omer Irfan

    2010-01-01

    Aim: The inhibitory effects of thallium-201 ( 201 Tl) solution on human erythrocyte glucose 6-phosphate dehydrogenase (G6PD) activity were investigated. Methods: For this purpose, erythrocyte G6PD was initially purified 835-fold at a yield of 41.7% using 2',5'-Adenosine diphosphate sepharose 4B affinity gel chromatography. The purification was monitored by sodium dodecyl sulfate-polyacrylamide gel electrophoresis, which showed a single band for the final enzyme preparation. The in vitro and in vivo effects of the 201 Tl solution including Tl + , Fe +3 and Cu +2 metals and the in vitro effects of the radiation effect of the 201 Tl solution and non-radioactive Tl + , Fe +3 and Cu +2 metals on human erythrocyte G6PD enzyme were studied. Enzyme activity was determined with the Beutler method at 340 nm using a spectrophotometer. All purification procedures were carried out at +4 deg. C. Results: 201 Tl solution and radiation exposure had inhibitory effects on the enzyme activity. IC 50 value of 201 Tl solution was 36.86 μl ([Tl + ]: 0.0036 μM, [Cu +2 ]: 0.0116 μM, [Fe +3 ]: 0.0132 μM), of human erythrocytes G6PD. Seven human patients were also used for in vivo studies of 201 Tl solution. Furthermore, non-radioactive Tl + , Fe +3 and Cu +2 were found not to have influenced the enzyme in vitro. Conclusion: Human erythrocyte G6PD activity was inhibited by exposure for up to 10 minutes to 0.057 mCi/kg 201 Tl solution. It was detected in in vitro and in vivo studies that the human erythrocyte G6PD enzyme is inhibited due to the radiation effect of 201 Tl solution.

  1. Impact of precursor purity on optical properties and radiation detection of CsI:Tl scintillators

    Energy Technology Data Exchange (ETDEWEB)

    Saengkaew, Phannee; Cheewajaroen, Kulthawat; Yenchai, Chadet; Thong-aram, Decho [Chulalongkorn University, Department of Nuclear Engineering, Faculty of Engineering, Bangkok (Thailand); Sanorpim, Sakuntam [Chulalongkorn University, Department of Physics, Faculty of Science, Bangkok (Thailand); Jitpukdee, Manit [Kasetsart University, Department of Applied Radiation and Isotope, Faculty of Science, Bangkok (Thailand); Yordsri, Visittapong; Thanachayanont, Chanchana [Ministry of Science and Technology, National Metal and Materials Technology Center, National Science and Technology Development Agency, Pathumthani (Thailand); Nuntawong, Noppadon [Ministry of Science and Technology, National Electronic and Computer Technology Center, National Science and Technology Development Agency, Pathumthani (Thailand)

    2016-08-15

    Cesium iodide doped with thallium (CsI:Tl) crystals was grown to develop the gamma-ray detectors by using low-cost raw materials. Effect of impurities on optical properties and radiation detection performance was investigated. By a modified homemade Bridgman-Stockbarger technique, CsI:Tl samples were grown in two levels of CsI and TlI reactant materials, i.e., having as a very high purity of 99.999 % and a high purity of 99.9 %. XRD measurements indicate CsI:Tl crystals having a good quality with a dominant (110) plane. Having a cubic structure, a lattice constant of CsI crystals of 0.4574 nm and a crystallite size of 43.539 nm were obtained. From the lower-purity raw materials, calcite was found in an orange crystal with a lattice constant of 0.4560 nm and a crystallite size of 43.089 nm. By PL measurements, the optical properties of the CsI:Tl crystals were analyzed. ∝540-nm-wavelength PL peak was observed from the colorless high-purity crystal, and ∝600-nm-wavelength PL peak was observed from the orange crystal. The brighter PL emission was obtained from the orange crystals suggesting impurities. CsI:Tl surface morphology by SEM exhibited a smooth surface with some parallel crystal facets. For electrical properties of high-quality CsI:Tl crystals, the electrical resistances were 230 ± 16 MΩ in cross-sectional direction and 714 ± 136 MΩ in vertical direction with respect to more homogeneous crystal quality in cross-sectional direction than that in vertical direction. TEM measurement was applied to evaluate the microstructure of colorless CsI:Tl crystal with different patterns of a cubic structure. Both CsI:Tl crystals show good efficiencies and good resolutions. Maintaining the same electronic conditions and amplifications, the colorless CsI:Tl scintillators represented a higher detection efficiency at 122 keV of Co-57 of 78.4 % and the energy resolution of 23.3 % compared to the detection efficiency of 75.9 % and the energy resolution of 34.6 % of the

  2. Investigation of TL, OSL and PTTL properties of Mg2SiO4:Tb dosimeters

    International Nuclear Information System (INIS)

    Oguz, K. F.; Goekce, M.; Karali, T.; Harmansah, C.

    2010-01-01

    In this study thermoluminescence (TL) and optically stimulated luminescence (OSL) properties of Mg 2 SiO 4 :Tb in the form of sintered pellets were investigated. Mg 2 SiO 4 :Tb is a recently developed dosimetric material which offers high sensitivity for TL and OSL in dosimetric applications. Thermoluminescence glow curve of Tb doped Mg 2 SiO 4 samples show a glow peak at about 200 degree Celsius with two small peaks at about 275 and 330 degree Celsius, respectively. OSL experiments showed that blue light (470 nm) is six times more efficient than green light (532 nm) to stimulate the OSL emission. The aim of this study was to determine the TL and OSL fading properties of Mg 2 SiO 4 : Tb using OSL and TL methods. In addition, PTTL properties of the Mg 2 SiO 4 : Tb was investigated by using blue LEDs, UV lamp and blue laser. Investigations on the fading properties also showed that the TL signal fades % 10 in a period of 1 month and OSL signal fades % 10 in a period of 3 month, which then the signal remains relatively stable for longer periods.

  3. Magnetic properties of Bi- and Tl- based new high-Tc superconductors

    International Nuclear Information System (INIS)

    Togano, K.; Kumakura, H.; Dietderich, D.H.

    1988-01-01

    Upper critical field H c2 and Magnetization curve were measured for new high-T c oxide superconductors of Bi-Sr-Ca-Cu-O and Tl-Ba-Ca-Cu-O systems. H c2 values at 77K for the high-T phase of Bi-Sr-Ca-Cu-O, low-T c (T c (ρ = 0) = 105K) phase of Tl-Ba-Ca-Cu-O, and high-T c (T c (ρ = 0)=115K) phase of Tl-Ba-Ca-Cu-O are 41T, 50T, and 100T, respectively. The magnetization curve of the Bi-Sr-Ca-Cu-O shows a relatively small hysterisis, suggesting a weak pinning force compared to Tl-Ba-Ca-Cu-O as well as Ba 2 YCU 3 O x . Critical current density J c of 600A/Cm 2 at 77K and zero-magnetiac field was attained for the high-T c sample of Tl-Ba-Ca-Cu-O

  4. Preparation and biodistribution of [201Tl](III)vancomycin complex in normal rats

    International Nuclear Information System (INIS)

    Jalilian, A.R.; Hosseini, M.A.; Karimian, A.; Saddadi, F.; Sadeghi, M.

    2006-01-01

    Thallium-201 (T 1/2 = 3.04 days) in Tl + form was converted to Tl 3+ cation in presence of O 3 in 6 M HCl controlled by RTLC/gel electrophoresis methods. The final evaporated activity was reacted with vancomycin (VAN) in water to yield [ 201 Tl](III)VAN. The best results were obtained at room temperature in water after 30 min with a radiochemical yield >99%, after mixing the reactants followed by SPE purification using Si Sep-Pak. The studies showed that thallic ion is mostly incorporated into vancomycin with a radiochemical purity of more than 98 ± 1% by RTLC. A specific activity of about 4.14·10 10 Bq/mmol was obtained. Radiochemical purity and stability of 201 Tl-VAN in the preparation and in presence of human serum was determined up to 5.5 days. Biodistribution study of 201 Tl(III)-vancomycin in normal rats was performed up to 52 h. (authors)

  5. Sand as in situ TL dosimeter in radiation hygienisation of sewage sludge

    International Nuclear Information System (INIS)

    Benny, P.G.; Bhatt, B.C.

    1999-01-01

    Recently, we have investigated the thermoluminescence (TL) properties of the sand, collected from the sewage sludge, after various extensive cleansing procedures. In the present studies, the sand separated from the sludge was used to estimate irradiation dose to sludge at Sludge Hygienisation Research Irradiator (SHRI), Vadodara, India. A dose vs TL response calibration curve was established for the 220 deg. C TL peak for the hydrogen peroxide (H 2 O 2 )-treated and HF-treated sludge sand samples collected from the unirradiated batch. This was used to estimate the dose absorbed in the corresponding batch of the irradiated sludge. Similar curve was plotted for the 370 deg. C TL peak for the HF-treated sand samples for its application as an in-situ dosimeter. Using this method, the absorbed dose rate delivered to the sludge during irradiation at SHRI was estimated to be 0.49 ± 0.02 kGy per hour. Also, the saturation levels of the TL response curves for these peaks are reported here. (author)

  6. Importance of the effective atomic number (Zeff) of TL materials for radiation dosimetry in clinical applications

    International Nuclear Information System (INIS)

    Gonzalez M, P.R.

    2008-01-01

    The electric power generation, it has been one of the radiation applications of bigger weight, mainly in developed countries. Another sector of more impact is without a doubt that of the medicine. However, for a sure operation with radiations, those international organisms of radiological safety, exist every time more precise detection systems. The thermoluminescent dosimetry is one of the more reliable methods for this purpose, for that several groups of investigators from different parts of the world, they have guided its investigations in the development of new TL materials. However, to avoid underestimate or overestimation of the measured dose with the use of these materials, it should take into account it effective atomic number (Z eff ) it is well known that some TL materials considered as equivalent to the tissue, presents smaller TL intensity when being irradiated with low energy photons, while the TL material known as not equivalent to the tissue, they present the supra sensitivity effect for this radiation type. Nowadays, the estimate of the Z eff has not been clear, in this work the Z eff is determined by means of the traditional methods and an own method is presented for its determination. The results of the TL signal of different materials, when being irradiated with photons of effective energy between 24 keV and 1.25 MeV and their relationship with their calculated Z eff are also presented. (Author)

  7. Correlation of an abnormal rest /sup 201/Tl myocardial image: Pathological findings in cardiac transplant recipients

    Energy Technology Data Exchange (ETDEWEB)

    McKillop, J.H.; McDougall, I.R.; Billingham, M.; Schroeder, J.S.

    1982-06-01

    Rest myocardial /sup 201/Tl scintigraphy was undertaken in 15 males mean age 39 years (22-54) who had been accepted for cardiac transplantation. Complete pathological correlation was obtained in 14 after transplantation and in 1 who died before a suitable donor heart became available. The average time from scintigraphy to pathological evaluation was 42 days (9-103). All the /sup 201/Tl images were grossly abnormal and on the basis of these studies it was not possible to differentiate ischemic from idiopathic cardiomyopathy. Each of the three views of the /sup 201/Tl study was divided into three segments, therefore 135 areas were available for comparison (3 x 3 x 15). Eighty-eight of these were abnormal on scan and 78 of these were abnormal pathologically. The right ventricle was seen on all rest images but the degree of uptake bore no relationship to the measured thickness of the right ventricular wall. Structures such as the atrial wall and the enlarged papillary muscle were visualized in some patients. In two patients there was an improvement of the rest /sup 201/Tl image in delayed views and histologically these areas showed a mixture of muscle and fibrous tissue. The sensitivity of /sup 201/Tl imaging in this study was 89% and there was close correlation of the images with gross and microscopic pathological findings.

  8. An analysis of annual maximum streamflows in Terengganu, Malaysia using TL-moments approach

    Science.gov (United States)

    Ahmad, Ummi Nadiah; Shabri, Ani; Zakaria, Zahrahtul Amani

    2013-02-01

    TL-moments approach has been used in an analysis to determine the best-fitting distributions to represent the annual series of maximum streamflow data over 12 stations in Terengganu, Malaysia. The TL-moments with different trimming values are used to estimate the parameter of the selected distributions namely: generalized pareto (GPA), generalized logistic, and generalized extreme value distribution. The influence of TL-moments on estimated probability distribution functions are examined by evaluating the relative root mean square error and relative bias of quantile estimates through Monte Carlo simulations. The boxplot is used to show the location of the median and the dispersion of the data, which helps in reaching the decisive conclusions. For most of the cases, the results show that TL-moments with one smallest value was trimmed from the conceptual sample (TL-moments (1,0)), of GPA distribution was the most appropriate in majority of the stations for describing the annual maximum streamflow series in Terengganu, Malaysia.

  9. Regional analysis of annual maximum rainfall using TL-moments method

    Science.gov (United States)

    Shabri, Ani Bin; Daud, Zalina Mohd; Ariff, Noratiqah Mohd

    2011-06-01

    Information related to distributions of rainfall amounts are of great importance for designs of water-related structures. One of the concerns of hydrologists and engineers is the probability distribution for modeling of regional data. In this study, a novel approach to regional frequency analysis using L-moments is revisited. Subsequently, an alternative regional frequency analysis using the TL-moments method is employed. The results from both methods were then compared. The analysis was based on daily annual maximum rainfall data from 40 stations in Selangor Malaysia. TL-moments for the generalized extreme value (GEV) and generalized logistic (GLO) distributions were derived and used to develop the regional frequency analysis procedure. TL-moment ratio diagram and Z-test were employed in determining the best-fit distribution. Comparison between the two approaches showed that the L-moments and TL-moments produced equivalent results. GLO and GEV distributions were identified as the most suitable distributions for representing the statistical properties of extreme rainfall in Selangor. Monte Carlo simulation was used for performance evaluation, and it showed that the method of TL-moments was more efficient for lower quantile estimation compared with the L-moments.

  10. Evaluation of coronary hemodynamics and exercise 201Tl-myocardial scintigraphy in patients with vasospastic angina

    International Nuclear Information System (INIS)

    Matsumura, Kentaro; Nakase, Emiko; Haiyama, Tohru; Hasegawa, Akira; Saito, Takayuki

    1992-01-01

    To clarify the coronary hemodynamics and myocardial perfusion in patients with vasospastic angina, we performed exercise 201 Tl-myocardial scintigraphy (planar and SPECT) in 72 patients and left coronary digital subtraction angiography (DSA) in 37 patients without significant organic coronary artery stenosis. Coronary artery spasm was documented by coronary angiography in all patients. Fifty-four patients (75%) developed exercise-induced 201 Tl-myocardial perfusion defect on SPECT. 201 Tl pulmonary uptake (L/H) was significantly increased in patients with vasospastic angina. Especially, L/H was higher in patients with multiple small perfusion defect on 201 Tl-SPECT, so that exercise-induced left ventricular dysfunction existed in patients with vasospastic angina and especially in cases of multiple small perfusion defect on 201 Tl-SPECT. The left coronary circulation time (CCT) was prolonged in patients with vasospastic angina. The mechanism of prolonged CCT is still unknown, but we suspected that prolonged CCT was induced by increased peripheral coronary vascular resistance in patients with vasospastic angina. It was concluded that the peripheral coronary circulation was disturbed in patients with vasospastic angina, but its abnormal coronary circulation had no relation to location of spasm-induced vessels. We concluded that impaired coronary microcirculation was taken a part of pathophysiology in vasospastic angina. (author)

  11. Measurement of the infarcted area by 201Tl myocardial emission CT

    International Nuclear Information System (INIS)

    Tamaki, Shunichi; Murakami, Tomoyuki; Kambara, Hirofumi

    1982-01-01

    201 Tl-ECT was performed in 28 cases 4 weeks after the onset of acute myocardial infarction to calculate the volume of infarction for comparison with the CK-MB infarction size obtained in the acute phase. The infarct area obtained by two-dimensional 201 Tl scintigraphy in 18 cases treated by the conventional method showed a positive correlation with the CK-MB infarct size, but the volume of infarction by 201 Tl-ECT produced a better correlation. In the group with successful thrombolysis, the serum CK-MB level reached a peak soon after the onset, accompanied by release of more CK-MB for a constant volume of infarction obtained by 201 Tl-ECT, as compared with the group with unsuccessful thrombolysis or conventional therapy. This suggests the involvement of washout phenomenon by reperfusion. Although there are some limitations, the three-dimensional detection of the distribution of myocardial blood flow by 201 Tl-ECT is useful, covering disadvantages of two-dimensional images. (Chiba, N.)

  12. Temperature dependence of positron annihilation parameters in Tl-Ba-Ca-Cu-O superconductors

    International Nuclear Information System (INIS)

    Sundar, C.S.; Bharathi, A.; Ching, W.Y.; Jean, Y.C.; Hor, P.H.; Meng, R.L.; Huang, Z.J.; Chu, C.W.

    1990-01-01

    The results of positron lifetime and Doppler broadened line-shape parameter measurements as a function of temperature, across T c , in the Tl-Ba-Ca-Cu-O superconductors are presented. The bulk lifetime in the normal state is found to decrease with the increase in the number of CuO 2 layers. Different temperature dependencies of the annihilation parameters are observed in the various Tl systems containing different numbers of CuO 2 layers. In the Tl 2 Ba 2 Ca 2 Cu 3 O 10 system, an increase in lifetime is observed below T c , whereas in Tl 2 Ba 2 CaCu 2 O 8 , a decrease in lifetime is seen below T c . In the Tl 2 Ba 2 CuO 6 system, the lifetime is observed to be temperature independent. The different temperature variations of positron annihilation parameters are discussed in the light of the positron density distribution, obtained with use of the results of the self-consistent orthogonalized linear combination of atomic orbitals band-structure calculations. It is argued that the different temperature dependencies of the annihilation parameters is related to the positron density distribution within the unit cell and arise due to local charge transfer in the vicinity of the CuO 2 layer in the superconducting state

  13. Total Thyroidectomy

    Directory of Open Access Journals (Sweden)

    Lopez Moris E

    2016-06-01

    Full Text Available Total thyroidectomy is a surgery that removes all the thyroid tissue from the patient. The suspect of cancer in a thyroid nodule is the most frequent indication and it is presume when previous fine needle puncture is positive or a goiter has significant volume increase or symptomes. Less frequent indications are hyperthyroidism when it is refractory to treatment with Iodine 131 or it is contraindicated, and in cases of symptomatic thyroiditis. The thyroid gland has an important anatomic relation whith the inferior laryngeal nerve and the parathyroid glands, for this reason it is imperative to perform extremely meticulous dissection to recognize each one of these elements and ensure their preservation. It is also essential to maintain strict hemostasis, in order to avoid any postoperative bleeding that could lead to a suffocating neck hematoma, feared complication that represents a surgical emergency and endangers the patient’s life.It is essential to run a formal technique, without skipping steps, and maintain prudence and patience that should rule any surgical act.

  14. A high-resolution neutron diffraction study on Tl[sub 2]Ba[sub 2]CaCu[sub 2]O[sub 8-y]: y = 0, 0. 05, 0. 06

    Energy Technology Data Exchange (ETDEWEB)

    Ogborne, D.M.; Weller, M.T.; Lanchester, P.C. (Depts. of Chemistry and Physics, Univ. of Southampton (United Kingdom))

    1992-09-15

    Samples of Tl[sub 2]Ba[sub 2]CaCu[sub 2]O[sub 8-y] have been prepared with three different oxygen stoichiometries by reaction under various oxygen gas partial pressures. Powder neutron diffraction studies on these materials show that for y > 0 oxygen vacancies exist in the thallium-oxygen layer; filling this site results in a contraction of the lattice c-parameter with concomitant reduction in the apical Cu-O bond length but with an expansion of the copper-oxygen inter-layer distance. These structural changes which occur as a function of oxygen content are discussed in terms of the superconducting properties of these materials and compared with those of the Tl[sub 2]Ba[sub 2]Ca[sub 2]Cu[sub 3]O[sub 10-y] system. (orig.).

  15. Patients with gout have short telomeres compared with healthy participants: association of telomere length with flare frequency and cardiovascular disease in gout.

    Science.gov (United States)

    Vazirpanah, N; Kienhorst, L B E; Van Lochem, E; Wichers, C; Rossato, M; Shiels, P G; Dalbeth, N; Stamp, L K; Merriman, T R; Janssen, M; Radstake, T R D J; Broen, J Ca

    2017-07-01

    Chronic inflammation associates with increased senescence, which is a strong predictor for cardiovascular disease. We hypothesised that inflammation accelerates senescence and thereby enhances the risk of cardiovascular disease in gout. We assessed replicative senescence by quantifying telomere length (TL) in a discovery cohort of 145 Dutch patients with gout and 273 healthy individuals and validated our results in 474 patients with gout and 293 healthy participants from New Zealand. Subsequently, we investigated the effect of cardiovascular disease on TL of all participants. Also, we measured TL of CD4 + and CD8 + T lymphocytes, B lymphocytes, monocytes, natural killer cells and plasmacytoid dendritic cells. Additionally, we assessed the potential temporal difference in TL and telomerase activity. TL in PBMCs of healthy donors decreased over time, reflecting normal ageing. Patients with gout demonstrated shorter telomeres (p=0.001, R 2 =0.01873). In fact, the extent of telomere erosion in patients with gout was higher at any age compared with healthy counterparts at any age (pgout with cardiovascular disease had the shortest telomeres and TL was an independent risk factor for cardiovascular disease in patients with gout (p=0.001). TL was inversely associated with the number of gouty flares (p=0.005). Patients with gout have shorter telomeres than healthy participants, reflecting increased cellular senescence. Telomere shortening was associated with the number of flares and with cardiovascular disease in people with gout. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  16. Dating archeological ceramics from the Valley of Vitor, Arequipa by the TL method

    Science.gov (United States)

    Cano, N. F.; Arizaca, E. C.; Yauri, J. M.; Arenas, J. S. A.; Watanabe, S.

    The age of some ancient pottery from the Valley of Vitor in the region of Arequipa, Peru, is determined by the thermoluminescence (TL) method. For dating, a 325 °C TL peak was used and irradiation with γ-dose from 5 to 50 Gy was carried out for the additive method, and from 0.4 to 5 Gy for the regeneration method. For these dose values, the TL intensity is observed to grow linearly, obtaining an accumulated dose of 1.62±0.09 Gy and 1.36±0.03 Gy for the additive and regeneration methods, respectively. The age (A) of the sample was calculated by the two methods, being A=867±195 years after Christ (AC) for the additive method and A=1050±157 years AC for the regeneration method. Both results are within 800-1200 years AC, which is the period of the Wari culture.

  17. Dielectric Losses and Charge Transfer in Antimony-Doped TlGaS2 Single Crystal

    Science.gov (United States)

    Asadov, S. M.; Mustafaeva, S. N.

    2018-03-01

    Effect of semimetallic antimony (0.5 mol % Sb) on the dielectric properties and ac-conductivity of TlGaS2-based single crystals grown by the Bridgman-Stockbarger method has been studied. The experimental results on the frequency dispersion of dielectric coefficients and the conductivity of TlGa0.995Sb0.005S2 single crystals allowed the revealing of the dielectric loss nature, the charge transfer mechanism, and the estimation of the parameters of the states localized in the energy gap. The antimony-doping of the TlGaS2 single crystal leads to an increase in the density of states near the Fermi level and a decrease in the average time and average distance of hopes.

  18. A new luminescence detection and stimulation head for the Risø TL/OSL reader

    International Nuclear Information System (INIS)

    Lapp, T.; Kook, M.; Murray, A.S.; Thomsen, K.J.; Buylaert, J.-P.; Jain, M.

    2015-01-01

    A new automated Detection And Stimulation Head (DASH) has been developed for the Risø TL/OSL luminescence reader to provide easy access to new technologies, new signals and new measurement methods. The automated DASH includes a filter changer and a detector changer that makes it possible to change stimulation filters (4 × 4 filter combinations possible) and detectors (3 detectors possible) as part of a measurements sequence. The new automated DASH with dedicated driver electronics does not affect the use of other attachments, and can be retrospectively fitted to existing Risø TL/OSL readers. - Highlights: • A new detection and stimulation head for the Risø TL/OSL reader is described. • An example of the use of the filter changer is presented. • The power and spatial uniformity of blue, green and IR stimulation are characterised. • The potential of an EMCCD camera detector is described.

  19. Sequential change of cardiomyopathy of Duchenne muscular dystrophy by 201Tl myocardial SPECT

    International Nuclear Information System (INIS)

    Ono, Seiji; Sugimoto, Seiichirou; Inoue, Kenjirou; Jinnouchi, Seishi; Hoshi, Hiroaki; Watanabe, Katsushi.

    1989-01-01

    201 Tl myocardial SPECT were performed to evaluate of cardiomyopathy in Duchenne type of progressive muscular dystrophy (DMD). Follow up SPECT images of the same patients were also obtained about 1 year after the first scan. Cases subjected to study were 10 DMD. At the first study the hypoperfusion area of the left ventricular muscle were observed in 6 cases (60%) out of 10. At the second study the hypoperfusion areas became wider and lower in 4 out of 6 cases (66.7%). The new hypoperfusion area which was not demonstrated at the first study was observed at the second study in one case of these cases. These results suggested that the positive rate of cardiomyopathy in DMD by 201 Tl myocardial SPECT was high, and 201 Tl myocardial SPECT is a useful examination to detect the change of myocardial damage in DMD. (author)

  20. Sequential change of cardiomyopathy of Duchenne muscular dystrophy by /sup 201/Tl myocardial SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Ono, Seiji; Sugimoto, Seiichirou; Inoue, Kenjirou; Jinnouchi, Seishi; Hoshi, Hiroaki; Watanabe, Katsushi.

    1989-03-01

    /sup 201/Tl myocardial SPECT were performed to evaluate of cardiomyopathy in Duchenne type of progressive muscular dystrophy (DMD). Follow up SPECT images of the same patients were also obtained about 1 year after the first scan. Cases subjected to study were 10 DMD. At the first study the hypoperfusion area of the left ventricular muscle were observed in 6 cases (60%) out of 10. At the second study the hypoperfusion areas became wider and lower in 4 out of 6 cases (66.7%). The new hypoperfusion area which was not demonstrated at the first study was observed at the second study in one case of these cases. These results suggested that the positive rate of cardiomyopathy in DMD by /sup 201/Tl myocardial SPECT was high, and /sup 201/Tl myocardial SPECT is a useful examination to detect the change of myocardial damage in DMD. (author).

  1. Pulsed laser deposition of Tl-Ca-Ba-Cu-O films

    International Nuclear Information System (INIS)

    Ianno, N.J.; Liou, S.H.; Woollam, J.A.; Thompson, D.; Johs, B.

    1990-01-01

    Pulsed laser deposition is a technique commonly used to deposit high quality thin films of high temperature superconductors. This paper discusses the results obtained when this technique is applied to the deposition of Tl-Ca-Ba-Cu-O thin films using a frequency doubled Nd:YAG laser operating at 532 nm and an excimer laser operating at 248 nm. Films with onset temperatures of 125 K and zero resistance temperatures of 110 K deposited on (100) oriented MgO from a composite Tl2Ca2Ba2Cu3Ox target were obtained at both wavelengths upon appropriate post deposition annealing. Films deposited at 532 nm exhibit a rough surface, while those deposited at 248 nm are smooth and homogeneous. Upon annealing, films deposited at both wavelengths are single phase Tl2Ca2Ba2Cu3Ox. 12 refs

  2. Magnetic measurements on Tl-2212 and Bi-2212 single crystals: a comparative study

    Energy Technology Data Exchange (ETDEWEB)

    Oussena, M. (Physics Dept., Univ. of Southampton (United Kingdom)); Porter, S. (Physics Dept., Univ. of Southampton (United Kingdom)); Volkozub, A. (Physics Dept., Univ. of Southampton (United Kingdom)); De Groot, P.A.J. (Physics Dept., Univ. of Southampton (United Kingdom)); Lanchester, P.C. (Physics Dept., Univ. of Southampton (United Kingdom)); Ogborne, D. (Physics Dept., Univ. of Southampton (United Kingdom) Chemistry Dept., Univ. of Southampton (United Kingdom)); Weller, M.T. (Physics Dept., Univ. of Southampton (United Kingdom) Chemistry Dept., Univ. of Southampton (United Kingdom)); Balakrishnan, G. (Physics Dept., Univ. of Southampton (United Kingdom) Physics Dept., Univ. of Warwick, Coventry (United Kingdom)); Paul, D.McK. (Physics Dept., Univ. of Southampton (United Kingdom) Physics Dept., Univ. of Warwick, Coventry (United Kingdom))

    1994-02-01

    We have compared the magnetic behaviour of two identically shaped single crystals, Tl[sub 2]Ba[sub 2]CaCu[sub 2]O[sub 8] and Bi[sub 2]Sr[sub 2]CaCu[sub 2]O[sub 8]. The critical current density is found to decrease more rapidly with temperature in Bi-2212 although it is the highest in this material at low temperatures (T < 10K). I-V characteristic curves have been obtained from measurements of magnetic sweep rate dependencies of the hysteresis loops. We have found that the characteristic temperature at which flux motion becomes important is significantly higher in Tl-2212 than in Bi-2212. Hence the Tl-2212 has a larger effective pinning. (orig.)

  3. Magnetic measurements on Tl-2212 and Bi-2212 single crystals: a comparative study

    International Nuclear Information System (INIS)

    Oussena, M.; Porter, S.; Volkozub, A.; De Groot, P.A.J.; Lanchester, P.C.; Ogborne, D.; Weller, M.T.; Balakrishnan, G.; Paul, D.McK.

    1994-01-01

    We have compared the magnetic behaviour of two identically shaped single crystals, Tl 2 Ba 2 CaCu 2 O 8 and Bi 2 Sr 2 CaCu 2 O 8 . The critical current density is found to decrease more rapidly with temperature in Bi-2212 although it is the highest in this material at low temperatures (T < 10K). I-V characteristic curves have been obtained from measurements of magnetic sweep rate dependencies of the hysteresis loops. We have found that the characteristic temperature at which flux motion becomes important is significantly higher in Tl-2212 than in Bi-2212. Hence the Tl-2212 has a larger effective pinning. (orig.)

  4. Prognostic value of gated 201Tl myocardial perfusion SPECT imaging in patients with coronary artery disease

    International Nuclear Information System (INIS)

    Li Zicheng; Chen Xiaoming; Xu Hao

    2006-01-01

    Objective: To study the prognostic value of gated 201 Tl myocardial perfusion SPECT imaging in patients with coronary artery disease and assessment of therapy strategy for the individual patient. Methods: Eighty-four patients underwent rest and exercise stress 201 Tl gated myocardial perfusion SPECT imaging and were followed up for (32.92 ± 16.77) months. Images were studied using 17 segments and 1 to 4 scoring. Global summed stress score (SSS), summed rest score (SRS) and summed difference score (SDS=SSS-SRS) were also calculated. Post-stress and rest ejection fraction (EF) were automatically measured. Results: Nine cardiac events occurred (3.90% per year). SSS, SDS, SRS and EF were the independent predictors of cardiac events (P 201 Tl myocardial perfusion SPECT imaging can provide prognostic assessment for the patients with coronary artery disease and guide in selection of therapeutic strategy. Among all of the indices SSS is the best predictors of cardiac events. (authors)

  5. Value of planar 201Tl imaging in risk stratification of patients recovering from acute myocardial infarction

    International Nuclear Information System (INIS)

    Gibson, R.S.; Watson, D.D.

    1991-01-01

    Although exercise ECG testing has been shown to have important prognostic value after acute myocardial infarction, exercise 201Tl scintigraphy offers several potential advantages, including: (1) increased sensitivity for detecting residual myocardial ischemia; (2) the ability to localize ischemia to a specific area or areas subtended by a specific coronary artery; (3) the ability to identify exercise-induced left ventricular dysfunction, which is manifested by increased lung uptake or transient left ventricular dilation; and (4) more reliable risk stratification of individual patients. The more optimal prognostic efficiency of 201Tl scintigraphy partially results from the fact that the error rate in falsely classifying patients as low risk is significantly smaller with 201Tl scintigraphy than with stress ECG. Because of these substantial advantages, there seems to be adequate rationale for recommending exercise perfusion imaging rather than exercise ECG alone as the preferred method for evaluating mortality and morbidity risks after acute myocardial infarction

  6. Correlation between TL and OSL properties of CaF2:N

    International Nuclear Information System (INIS)

    Polymeris, George S.; Kitis, George; Tsirliganis, Nestor C.

    2006-01-01

    Natural CaF 2 is very well known thermoluminescent (TL) material, since it has been extensively used as a dosimeter. Its basic advantage is the exhibited high TL sensitivity. In the present work, the optically stimulated luminescence (OSL) sensitivity of this material was studied by exposing it to environmental radiation for time intervals of few hours up to a few days, and was found to be very high. By analyzing the TL glow curves and the OSL decay curves into their individual glow-peaks and components respectively, a relation between specific glow-peaks and OSL components was established. An intense thermal transfer effect occurring during optical stimulation at high temperature was observed and an explanation is offered according to existing models

  7. Removal of 99mTc and 201Tl by means of Lemna Gibba

    International Nuclear Information System (INIS)

    Fernandez R, E.; Carreno de L, M. C.; Cuevas S, J. C.; Hernadez T, U. O.; Monroy G, F.

    2012-10-01

    In this work the capacity of the water macrophyte Lemna gibba coming from San Pedro Tultepec in the Mexico State was studied to remove the radioisotopes 99m Tc and 201 Tl, in order to show the capacity of this macrophyte for to treat some radioactive waste flowing that could contain this radioisotopes type. The removal capacity of 99m Tc and 201 Tl of the macrophyte Lemna gibba was determined using the batch method. In accordance with the values of the obtained K d , the Lemna gibba with a size of particle diameter among 1mm - 300 μm presents a better adsorption of 99m Tc. The 201 Tl is adsorbed better in the bioadsorbent when it has a size of particle diameter <150μm. (Author)

  8. First approval procedure of the TL dosimetric service of the NPP in Slovenia

    International Nuclear Information System (INIS)

    Janzekovic, H.; Krizman, M.; Pucelj, B.; Stuhec, M.; Zdesar, U.

    2001-01-01

    The individual dosimetry of exposed workers in a NPP is one of the essential parts which demonstrates the radiation protection standards achieved in a facility. According to the current legislation the Ministry of Health of the Republic of Slovenia has the authority to grant approvals to personal dosimetric services which perform the dosimetric monitoring of workers in Slovenia. Due to the fact that the detailed approval procedure is not given in national regulations, the Ministry of Health in 2000 established a group of experts with the task to prepare technical and organising requirements for such approval. Based on international documents [1,2,3] the Approval procedure for the thermoluminescence dosimetric (TL) services was created. Following this procedure the assessment of the TL dosimetric service in the NPP was performed. The problems related to the technical and organising requirements with the emphasise on the QA/QC criteria of the TL dosimetric service will be discussed.(author)

  9. OSL and TL retrospective dosimetry with a fluorapatite glass-ceramic used for dental restorations

    International Nuclear Information System (INIS)

    Ekendahl, Daniela; Judas, Libor; Sukupova, Lucie

    2013-01-01

    Optically Stimulated Luminescence (OSL) and Thermoluminescence (TL) properties of a fluorapatite glass-ceramic have been investigated, with a view to developing a dose assessment technique for medical triage following unplanned exposures of individuals to ionizing radiation. The ceramic is an innovative material used in dental prostheses and restorations. It is strongly sensitive to radiation and the intensity of both the OSL and TL signals are proportional to the absorbed radiation dose. We focused on the optimization of the measuring procedure and investigated characteristics such as reproducibility, fading, minimum detectable dose (MDD), dose response and photon energy response of TL and OSL signals. The dental ceramic exhibited very good reproducibility (<5% at 2σ level) when measured and a linear dose response for a wide range of doses (50 mGy–20 Gy). The MDD values for the samples investigated were ∼5 mGy. The material is not tissue equivalent and the OSL and TL signals are strongly dependent on incident photon energy. Both the luminescence signals exhibited significant fading during the first few hours after irradiation. Its rate was dependent on the parameters of measurement. The results indicate that the material can be used for the purposes of accident dosimetry, however, the fading and photon energy response have to be properly corrected for a reliable dose assessment. - Highlights: ► A dental ceramic was considered as a retrospective and accident dosimeter. ► Dosimetry application was investigated using OSL and TL. ► TL and OSL signals are proportional to absorbed radiation dose. ► Accuracy is dependent on correction of fading and photon energy response

  10. Coronary collateral circulation during exercise assessed with stress Tl-201 SPECT

    International Nuclear Information System (INIS)

    Tanaka, Takeshi; Aizawa, Tadanori

    1995-01-01

    Stree Tl-201 single photon emission computed tomography (SPECT) was undertaken in 25 patients with complete occlusion of the left anterior descending artery in which the major collateral circulation was septal segment supplied by the right posterior descending artery with no significant occlusion. The ratio of blood flow in ischemic area to that in normal area was quantitatively determined on Tl-201 images, and the degree of ischemia was expressed by Tl uptake ratio. Ischemia was found in 22 of the 25 patients. Of the 22 patients, 9 showed Tl uptake ratio of less than 50%. Tl uptake ratio in the inferior segment was 76.8±10.3%. In 11 patients, it was less than 75%. Redistribution images were acquired in 19 patients. Changes in Tl uptake ratio on the 90 degrees projection of the septum were less than 20%, with a lowest value of 59.1±11.3% in 14 patients; and these were 20% or more, with a lowest value of 45.2±11.1% in 8 patients. When coronary collateral circulation is not supplied by exercise, septal perfusion may be decreased. In cases of complete occlusion of the anteiror descending artery, ischemia may not uniform over the whole ischemic area and may be noticeable around the anterior descending artery. In cases of lesions in the anteior descending artery, however, collateral circulation supplied by the right coronary artery may occur by exercise when ischemia in the anterior segment was severer than in the septal segment. (N.K.)

  11. Tl and OSL dosimetry of diamond films CVD pure and unpurified with boron-carbon

    International Nuclear Information System (INIS)

    Melendrez, R.; Pedroza M, M.; Chernov, V.; Ochoa N, J.D.; Bernal, R.; Barboza F, M.; Castaneda, B.; Goncalves, J.A.N.; Sandonato, G.M.; Cruz Z, E.; Preciado F, S.; Cruz V, C.; Brown, F.; Schreck, M.

    2004-01-01

    The diamond is a material that possesses extreme physical properties, such as its hardness to the radiation, its low chemical reactivity besides its equivalence to the human tissue, which qualify him as an ideal material for radiation dosimetry. In this work, it was studied the thermal and optically stimulated response (Tl and OSL) of polycrystalline diamond films grown by the technique of CVD pure and contaminated with Boron-carbon (B/C) with the intention of characterizing their efficiency like a dosemeter for radiation in a range of 0 - 3000 Gy. For the case of the films without impurities, the Tl curve presents four main peaks, two of them in an interval of temperatures of 150-200 C and other two additional around of 250-400 C. The dependence of the response of integrated Tl and that of OSL always maintained a lineal relationship with the exhibition dose up to 100 Gy. The behavior of the films contaminated with B/C (2000 - 20000 ppm) was established through experiments that involved the signal of OSL and their relationship with the Tl response. It was found that this processes are correlated, since the electrons caught in the traps of low temperature (50 - 250 C) of the Tl they are the electrons that recombining with more probability to provide the signal of OSL. According to these results it is possible to propose the diamond films as a good candidate for dosimetry to, using the traditional technique of Tl so much as well as the but recent of OSL. (Author)

  12. Comparison of telomere length and insulin-like growth factor-binding protein 7 promoter methylation between breast cancer tissues and adjacent normal tissues in Turkish women.

    Science.gov (United States)

    Kaya, Zehra; Akkiprik, Mustafa; Karabulut, Sevgi; Peker, Irem; Gullu Amuran, Gokce; Ozmen, Tolga; Gulluoglu, Bahadır M; Kaya, Handan; Ozer, Ayse

    2017-09-01

    Both insulin-like growth factor-binding protein 7 (IGFBP7) and telomere length (TL) are associated with proliferation and senescence of human breast cancer. This study assessed the clinical significance of both TL and IGFBP7 methylation status in breast cancer tissues compared with adjacent normal tissues. We also investigated whether IGFBP7 methylation status could be affecting TL. Telomere length was measured by quantitative PCR to compare tumors with their adjacent normal tissues. The IGFBP7 promoter methylation status was evaluated by methylation-specific PCR and its expression levels were determined by western blotting. Telomeres were shorter in tumor tissues compared to controls (Pbreast cancer with invasive ductal carcinoma (IDC; n=72; P=.014) compared with other histological type (n=29), and TL in IDC with HER2 negative (n=53; P=.017) was higher than TL in IDC with HER2 positive (n=19). However, telomeres were shortened in advanced stages and growing tumors. IGFBP7 methylation was observed in 90% of tumor tissues and 59% of controls (P=.0002). Its frequency was significantly higher in IDC compared with invasive mixed carcinoma (IMC; P=.002) and it was not correlated either with protein expression or the other clinicopathological parameters. These results suggest that IGFBP7 promoter methylation and shorter TL in tumor compared with adjacent tissues may be predictive biomarkers for breast cancer. Telomere maintenance may be indicative of IDC and IDC with HER2 (-) of breast cancer. Further studies with larger number of cases are necessary to verify this association. © 2016 Wiley Periodicals, Inc.

  13. Telomere length is short in PCOS and oral contraceptive does not affect the telomerase activity in granulosa cells of patients with PCOS.

    Science.gov (United States)

    Li, Ying; Deng, Bingbing; Ouyang, Nengyong; Yuan, Ping; Zheng, Lingyan; Wang, Wenjun

    2017-07-01

    Our study aimed to investigate the association of telomerase activity (TA) and telomere length (TL) in granulosa cells (GCs) with IVF outcomes of polycystic ovary syndrome (PCOS) patients, and the effects of oral contraceptive pill (OCP) pretreatment on these two parameters. One hundred sixty-three infertile women were enrolled and divided into a PCOS group (n = 65) and a non-PCOS group (n = 98). The PCOS group was further divided into an OCP pretreatment group (n = 35) and a non-OCP pretreatment group (n = 30), a TA PCOS group and 1.118 in non-PCOS group (P = 0.005). The patients with TL ≥1 accounted for 36.9% in PCOS group and 54.1% in non-PCOS group (P = 0.032). The average duration of infertility for PCOS patients was 5 years in TA PCOS patients. Shorter TL was found in PCOS patients. The TA levels did not change significantly in PCOS patients. PCOS patients with a lower TA level and shorter telomeres had an earlier onset of infertility symptoms. No predictive value was found for TA and TL in terms of embryo quality or IVF outcomes in PCOS patients, and no effect OCP pretreatment was observed on either TA and TL.

  14. Clinical significance of increased lung/heart ratio in 210Tl stress myocardial image

    International Nuclear Information System (INIS)

    Liu Zaoli; Chang Fengqin; Zhang Fengge; Wang Xiaoyuan; Liu Liuhua

    1990-01-01

    230 cases were studied with 201 Tl stress image. The results showed that the lung/heart ratio closely correlated with the presence and severity of coronary heart disease (CHD). Among them, 18 cases (7.8%) showed significantly elevated lung/heart ratio (> 0.50). It was confirmed that all of the 18 cases have severe CHD with left ventricular insufficiency. The author emphasizes that measurement of the lung/heart ratio during 201 Tl stress myocardial image may be useful for the assessment of the severity, evalation of the left ventricular function and judgement of prognosis in CHD

  15. Performance of a high-resolution CsI(Tl)-PIN readout detector

    International Nuclear Information System (INIS)

    Kudenko, Yu.G.; Imazato, J.

    1992-10-01

    A study of a large-volume CsI(Tl) detector with a PIN diode readout was carried out. Our results show a light output of ≤20000 photoelectrons/MeV, an equivalent noise charge (rms) of about 900 electrons, and an equivalent noise level of ≤ 60 keV. We obtained an energy resolution of 11.2% (fwhm) for 1275 keV gamma rays from a 22 Na source. The characteristics of the PIN - preamplifier system as well as the parameters of a small CsI(Tl) - PIN detector with a direct and wavelength shifter readout are also reported. (author)

  16. Hyper- and hypobaric processing of Tl-Ba-Ca-Cu-O superconductors

    Science.gov (United States)

    Goretta, K. C.; Routbort, J. L.; Shi, Donglu; Chen, J. G.; Hash, M. C.

    1989-11-01

    Tl-based superconductors of initial composition Tl:Ca:Ba:Cu equal to 2:2:2:3 and 1:3:1:3 were heated in oxygen at pressures of 10(sup 4) to 6 (times) 10(sup 5) Pa. The 2:2:2:3 composition formed primarily the 2-layer superconductor with zero resistance from 77 to 104 K. The 1:3:1:3 composition formed nearly phase pure 3-layer superconductor with a maximum zero resistance temperature of 120 K. Application of hyperbaric pressure influenced phase purities and transition temperatures slightly; phase purities decreased significantly with application of hypobaric pressures.

  17. A portable in situ NaI(Tl) γ spectroscopy system

    International Nuclear Information System (INIS)

    Wang Bairong; Dong Binjiang; Zeng Liping

    1999-01-01

    The author describes a portable in situ NaI(Tl) γ spectroscopy system, which consists of a NaI(Tl) scintillation detector, an integrative spectroscopy card, a notebook computer and the spectroscopy software. The spectrometer addresses applications in environmental or nuclear accident in situ γ spectroscopy measurements, and gives valid quantitative results of radionuclide concentrations per unit volume (Bq/kg) or per unit area (Bq/cm 2 ) in the soil and absorbed dose rate in air 1 m above ground (Gy/h)

  18. Effect of temperature during UV and gamma irradiations of TL phosphor CaSO4:Dy

    International Nuclear Information System (INIS)

    Nagpal, J.S.; Pendurkar, H.K.

    1979-01-01

    Temperature is an important parameter in thermoluminescence studies. Irradiation at enhanced temperatures reduces the γ response of TL phosphor CaSO 4 :Dy. However, in the presence of fluorescent lights, the γ response of the phosphor is enhanced by approximately 20% for temperatures around 60-100 0 C. If the phosphor temperature during UV exposure is kept high, the integrated TL output continues to increase until it reaches 18 times at 160 0 C as compared to that produced by UV exposure at room temperature. (Auth.)

  19. The unfolding of NaI(Tl) γ-ray spectrum based on maximum likelihood method

    International Nuclear Information System (INIS)

    Zhang Qingxian; Ge Liangquan; Gu Yi; Zeng Guoqiang; Lin Yanchang; Wang Guangxi

    2011-01-01

    NaI(Tl) detectors, having a good detection efficiency, are used to detect gamma rays in field surveys. But the poor energy resolution hinders their applications, despite the use of traditional methods to resolve the overlapped gamma-ray peaks. In this paper, the maximum likelihood (ML) solution is used to resolve the spectrum. The ML method,which is capable of decomposing the peaks in energy difference of over 2/3 FWHM, is applied to scale NaI(Tl) the spectrometer. The result shows that the net area is in proportion to the content of isotopes and the precision of scaling is better than the stripping ration method. (authors)

  20. 201Tl myocard scintigraphy - a specialized non-invasive method in evaluating myocardial function

    International Nuclear Information System (INIS)

    Birke, S.; Deckart, H.; Mischke, W.; Schulz, J.; Koblitz, E.

    1985-01-01

    In 216 patients with ischemic heart disease (IHK) or with angina pectoris symptoms and suspected IHK the results of resting electrocardiograms were compared with those of 201 Tl scintigraphy under conditions of rest and exercise, resp. 201 Tl scintigraphy proved to be superior in sensitivity and specifity to the electrocardiograms of rest and under exercise as to the detection of coronary heart disease, the localization and assessment of the severity of coronary heart disease, and the evidence of load ischemia. Conclusions are drawn for a program of consecutive diagnostic steps in suspected IHK as well as for the evaluation of myocardial function in known IHK. (author)